Sample records for waste pet bottles

  1. A novel one-step synthesis for carbon-based nanomaterials from polyethylene terephthalate (PET) bottles waste.

    PubMed

    El Essawy, Noha A; Konsowa, Abdelaziz H; Elnouby, Mohamed; Farag, Hassan A

    2017-03-01

    Nowadays our planet suffers from an accumulation of plastic products that have the potential to cause great harm to the environment in the form of air, water, and land pollution. Plastic water bottles have become a great problem in the environment because of the large numbers consumed throughout the world. Certain types of plastic bottles can be recycled but most of them are not. This paper describes an economical solvent-free process that converts polyethylene terephthalate (PET) bottles waste into carbon nanostructure materials via thermal dissociation in a closed system under autogenic pressure together with additives and/or catalyst, which can act as cluster nuclei for carbon nanostructure materials such as fullerenes and carbon nanotubes. This research succeeded in producing and controlling the microstructure of various forms of carbon nanoparticles from the PET waste by optimizing the preparation parameters in terms of time, additives, and amounts of catalyst. Plastic water bottles are becoming a growing segment of the municipal solid waste stream in the world; some are recycled but many are left in landfill sites. Recycling PET bottles waste can positively impact the environment in several ways: for instance, reduced waste, resource conservation, energy conservation, reduced greenhouse gas emissions, and decreasing the amount of pollution in air and water sources. The main novelty of the present work is based on the acquisition of high-value carbon-based nanomaterials from PET waste by a simple solvent-free chemical technique. Thus, the prepared materials are considered to be promising, cheap, eco-friendly materials that may find use in different applications.

  2. The consumption and recycling collection system of PET bottles: a case study of Beijing, China.

    PubMed

    Zhang, Hua; Wen, Zong-Guo

    2014-06-01

    After studying the recycling collection system of polyethylene terephthalate (PET) bottles worldwide, the authors conducted an intercept survey in Beijing. Two separate questionnaires were issued, one questionnaire to PET bottle consumers and one to PET bottle recyclers. In this study, consumers are defined as people that consume PET-bottled beverages in their daily life. Recyclers were defined as those involved in the collection and recycling of PET bottles. These include scavengers, itinerant waste buyers, small community waste-buying depots, medium/large redemption depots, and recycling companies. In total, 580 surveys were completed, including 461 by consumers and 119 by recyclers. The authors found that consumption of PET bottles in Beijing was nearly 100,000 tonnes in 2012. Age, occupation, gender, and education were identified as significant factors linked to PET-bottled beverage consumption, while income was not a significant factor. 90% Of post-consumed PET bottles were collected by informal collectors (i.e., scavengers and itinerant waste buyers). The survey also found that nearly all PET bottles were reprocessed by small factories that were not designed with pollution control equipment, which allows them to offer higher prices for waste recyclable bottles. As Beijing is trying to build a formal recycling collection system for recyclables, subsidies should be given to the formal recycling sector rather than being charged land use fees, and attention should also be given to informal recyclers that make their living from the collection of recyclables. Informal and formal sectors may work together by employing the scavengers and itinerant waste buyers for the formal sectors. In addition to the recycling of PET bottles, concern should also be allocated to reduce consumption, especially among young people, as they, compared to other groups, have a stronger demand for PET-bottled beverages and will be the main body of society. Copyright © 2013 Elsevier Ltd

  3. Recycling policies and programmes for PET drink bottles in Mexico.

    PubMed

    Schwanse, Elvira

    2011-09-01

    Transition and emerging economies confront a steadily increasing generation of municipal solid waste in the form of disposable packaging. The following article reports the situation of soft drink bottles made of polyethylene terephthalate (PET) in Mexico. Since 2002 schemes following the European Green Dot principle have been partly implemented to place responsibility on the producer, mainly soft drink bottlers. Private stakeholders are responsible for national recovery activities. Meanwhile Government presence to promote recovery is absent. Of post-consumer PET 75% is exported, and the newly created bottle-to-bottle (BTB) PET industry is confronted with bottlenecks in their post-consumer PET supply.

  4. Value-added conversion of waste cooking oil and post-consumer PET bottles into biodiesel and polyurethane foams.

    PubMed

    Dang, Yu; Luo, Xiaolan; Wang, Feng; Li, Yebo

    2016-06-01

    A sustainable process of value-added utilization of wastes including waste cooking oil (WCO) and post-consumer PET bottles for the production of biodiesel and polyurethane (PU) foams was developed. WCO collected from campus cafeteria was firstly converted into biodiesel, which can be used as vehicle fuel. Then crude glycerol (CG), a byproduct of the above biodiesel process, was incorporated into the glycolysis process of post-consumer PET bottles collected from campus to produce polyols. Thirdly, PU foams were synthesized through the reaction of the above produced polyols with isocyanate in the presence of catalysts and other additives. The characterization of the produced biodiesel demonstrated that its properties meet the specification of biodiesel standard. The effect of crude glycerol loading on the properties of polyols and PU foams were investigated. All the polyols showed satisfactory properties for the production of rigid PU foams which had performance comparable to those of some petroleum-based analogs. A mass balance and a cost analysis for the conversion of WCO and waste PET into biodiesel and PU foams were also discussed. This study demonstrated the potential of WCO and PET waste for the production of value-added products. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. An investigation on the use of shredded waste PET bottles as aggregate in lightweight concrete.

    PubMed

    Akçaözoğlu, Semiha; Atiş, Cengiz Duran; Akçaözoğlu, Kubilay

    2010-02-01

    In this work, the utilization of shredded waste Poly-ethylene Terephthalate (PET) bottle granules as a lightweight aggregate in mortar was investigated. Investigation was carried out on two groups of mortar samples, one made with only PET aggregates and, second made with PET and sand aggregates together. Additionally, blast-furnace slag was also used as the replacement of cement on mass basis at the replacement ratio of 50% to reduce the amount of cement used and provide savings. The water-binder (w/b) ratio and PET-binder (PET/b) ratio used in the mixtures were 0.45 and 0.50, respectively. The size of shredded PET granules used in the preparation of mortar mixtures were between 0 and 4 mm. The results of the laboratory study and testing carried out showed that mortar containing only PET aggregate, mortar containing PET and sand aggregate, and mortars modified with slag as cement replacement can be drop into structural lightweight concrete category in terms of unit weight and strength properties. Therefore, it was concluded that there is a potential for the use of shredded waste PET granules as aggregate in the production of structural lightweight concrete. The use of shredded waste PET granules due to its low unit weight reduces the unit weight of concrete which results in a reduction in the death weight of a structural concrete member of a building. Reduction in the death weight of a building will help to reduce the seismic risk of the building since the earthquake forces linearly dependent on the dead-weight. Furthermore, it was also concluded that the use of industrial wastes such as PET granules and blast-furnace slag in concrete provides some advantages, i.e., reduction in the use of natural resources, disposal of wastes, prevention of environmental pollution, and energy saving.

  6. An investigation on the use of shredded waste PET bottles as aggregate in lightweight concrete

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Akcaoezoglu, Semiha, E-mail: sakcaozoglu@nigde.edu.t; Atis, Cengiz Duran; Akcaoezoglu, Kubilay

    2010-02-15

    In this work, the utilization of shredded waste Poly-ethylene Terephthalate (PET) bottle granules as a lightweight aggregate in mortar was investigated. Investigation was carried out on two groups of mortar samples, one made with only PET aggregates and, second made with PET and sand aggregates together. Additionally, blast-furnace slag was also used as the replacement of cement on mass basis at the replacement ratio of 50% to reduce the amount of cement used and provide savings. The water-binder (w/b) ratio and PET-binder (PET/b) ratio used in the mixtures were 0.45 and 0.50, respectively. The size of shredded PET granules usedmore » in the preparation of mortar mixtures were between 0 and 4 mm. The results of the laboratory study and testing carried out showed that mortar containing only PET aggregate, mortar containing PET and sand aggregate, and mortars modified with slag as cement replacement can be drop into structural lightweight concrete category in terms of unit weight and strength properties. Therefore, it was concluded that there is a potential for the use of shredded waste PET granules as aggregate in the production of structural lightweight concrete. The use of shredded waste PET granules due to its low unit weight reduces the unit weight of concrete which results in a reduction in the death weight of a structural concrete member of a building. Reduction in the death weight of a building will help to reduce the seismic risk of the building since the earthquake forces linearly dependant on the dead-weight. Furthermore, it was also concluded that the use of industrial wastes such as PET granules and blast-furnace slag in concrete provides some advantages, i.e., reduction in the use of natural resources, disposal of wastes, prevention of environmental pollution, and energy saving.« less

  7. PET bottle use patterns and antimony migration into bottled water and soft drinks: the case of British and Nigerian bottles.

    PubMed

    Tukur, Aminu; Sharp, Liz; Stern, Ben; Tizaoui, Chedly; Benkreira, Hadj

    2012-04-01

    While antimony has been reported to migrate from PET bottles into contents, reports on bottled water and soft drinks usage and PET bottle reuse patterns are currently unavailable in the literature. Bottle use conditions and patterns are important determinants of antimony migration. In this work a survey assessing the pattern of bottle use and reuse in Britain and Nigeria was undertaken. The survey findings influenced the design of laboratory experiments that assessed the migration of antimony from PET bottles into water and soft drinks. Typical storage durations for bottled contents between purchase and opening for use were 7 days or less. However storage of up to one year was reported. Bottle reuse was high and similar for the two countries with reuse durations being higher in Nigeria. The antimony concentration in 32 PET bottle materials from Britain and Nigeria were similar and ranged between 177 and 310 mg kg(-1). For 47 freshly purchased British bottled contents antimony concentration ranged between 0.03 and 6.61 μg L(-1) with only one sample exceeding the EU acceptable limit. Concentrations of Cd, Ge, Zn, Al, Be, Ti, Co and Pb were also measured. At realistic temperatures of 40 and 60 °C antimony concentration in deionised water in bottles remained below the EU acceptable limit even after 48 h exposure. The limit was exceeded for most exposures at 80 °C. Concentration of antimony in some bottled contents exceeded the EU limit after 11 months of storage at room temperature. Bottle aging and increase in bottle volume were associated with decreased migration of antimony from bottles.

  8. Self-consolidating concretes containing waste PET bottles as sand replacement

    NASA Astrophysics Data System (ADS)

    Khalid, Faisal Sheikh; Azmi, Nurul Bazilah; Mazenan, Puteri Natasya; Shahidan, Shahiron; Othman, Nor hazurina; Guntor, Nickholas Anting Anak

    2018-02-01

    This study evaluates the effect of self-consolidating concrete (SCC) containing waste polyethylene terephthalate (PET) granules on the fresh, mechanical and water absorption properties. Fine aggregates were replaced from 0% to 8% by PET granules. The fresh properties of SCC containing PET granules were determined using slump flow and V-funnel flow time tests. The compressive and splitting tensile strength were evaluated. The results indicated that utilization of waste PET granules in production of SCC could be an effective way for recycling purpose. The maximum amount of PET replacement should be limited to 5%. Exceeding 5% of PET content may result in an increase of V-funnel flow time to overpass the limiting value, decrease in strength. The production of high performance SCC containing 5% PET granules satisfies all the requirements for SCC with satisfactory outputs.

  9. An approach to the usage of polyethylene terephthalate (PET) waste as roadway pavement material.

    PubMed

    Gürü, Metin; Çubuk, M Kürşat; Arslan, Deniz; Farzanian, S Ali; Bilici, İbrahim

    2014-08-30

    This study investigates an application area for Polyethylene Terephthalate (PET) bottle waste which has become an environmental problem in recent decades as being a considerable part of the total plastic waste bulk. Two novel additive materials, namely Thin Liquid Polyol PET (TLPP) and Viscous Polyol PET (VPP), were chemically derived from waste PET bottles and used to modify the base asphalt separately for this aim. The effects of TLPP and VPP on the asphalt and hot mix asphalt (HMA) mixture properties were detected through conventional tests (Penetration, Softening Point, Ductility, Marshall Stability, Nicholson Stripping) and Superpave methods (Rotational Viscosity, Dynamic Shear Rheometer (DSR), Bending Beam Rheometer (BBR)). Also, chemical structures were described by Scanning Electron Microscope (SEM) equipped with Energy Dispersive Spectrometer (EDS) and Fourier Transform Infrared (FTIR) techniques. Since TLPP and VPP were determined to improve the low temperature performance and fatigue resistance of the asphalt as well as the Marshall Stability and stripping resistance of the HMA mixtures based on the results of the applied tests, the usage of PET waste as an asphalt roadway pavement material offers an alternative and a beneficial way of disposal of this ecologically hazardous material. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Antimony leaching from polyethylene terephthalate (PET) plastic used for bottled drinking water.

    PubMed

    Westerhoff, Paul; Prapaipong, Panjai; Shock, Everett; Hillaireau, Alice

    2008-02-01

    Antimony is a regulated contaminant that poses both acute and chronic health effects in drinking water. Previous reports suggest that polyethylene terephthalate (PET) plastics used for water bottles in Europe and Canada leach antimony, but no studies on bottled water in the United States have previously been conducted. Nine commercially available bottled waters in the southwestern US (Arizona) were purchased and tested for antimony concentrations as well as for potential antimony release by the plastics that compose the bottles. The southwestern US was chosen for the study because of its high consumption of bottled water and elevated temperatures, which could increase antimony leaching from PET plastics. Antimony concentrations in the bottled waters ranged from 0.095 to 0.521 ppb, well below the US Environmental Protection Agency (USEPA) maximum contaminant level (MCL) of 6 ppb. The average concentration was 0.195+/-0.116 ppb at the beginning of the study and 0.226+/-0.160 ppb 3 months later, with no statistical differences; samples were stored at 22 degrees C. However, storage at higher temperatures had a significant effect on the time-dependent release of antimony. The rate of antimony (Sb) release could be fit by a power function model (Sb(t)=Sb 0 x[Time, h]k; k=8.7 x 10(-6)x[Temperature ( degrees C)](2.55); Sb 0 is the initial antimony concentration). For exposure temperatures of 60, 65, 70, 75, 80, and 85 degrees C, the exposure durations necessary to exceed the 6 ppb MCL are 176, 38, 12, 4.7, 2.3, and 1.3 days, respectively. Summertime temperatures inside of cars, garages, and enclosed storage areas can exceed 65 degrees C in Arizona, and thus could promote antimony leaching from PET bottled waters. Microwave digestion revealed that the PET plastic used by one brand contained 213+/-35 mgSb/kg plastic; leaching of all the antimony from this plastic into 0.5L of water in a bottle could result in an antimony concentration of 376 ppb. Clearly, only a small

  11. [Safety verification for reuse of PET and glass bottles].

    PubMed

    Hayashi, Eiichi; Imai, Toshio; Niimi, Hiroji

    2011-01-01

    In order to verify the safety associated with reusing PET and glass bottles, a challenge test was conducted with five surrogate contaminants: 1,1,1-trichloroethane, chlorobenzene, toluene, benzophenone and phenyl cyclohexane. Bottles were filled with a cocktail solution of these contaminants and stored at 50 °C for 7 days, then washed with water and alkaline solutions. Material and migration tests were conducted at each step. The material test results showed that 430-1,440 µg/g of the contaminants were retained after water washing, and that even after washing with a 3.5% NaOH solution, 225-925 µg/g of the contaminants were retained. The migration tests revealed that 0.095-7.35 µg/mL of the contaminants were eluted. Similar tests were conducted with a soft drink ingredient, limonene. The results revealed that 48 µg/g of limonene was retained even after washing with NaOH solution, and that 0.16 µg/mL of limonene was eluted. Conversely, no contaminants were eluted from glass bottles after washing with the NaOH solution. Thus, from the viewpoint of safety and the preservation of content quality, PET bottles are not considered suitable for reuse when compared with glass bottles.

  12. Panel Board From Coconut Fibre And Pet Bottle

    NASA Astrophysics Data System (ADS)

    Ngadiman, Norhayati; Kaamin, Masiri; Abd. Kadir, Aslila; Sahat, Suhaila; Zaini, Aziza; Raihana Nor Zentan, Siti; Ain Ahmad, Nur; Amran, Wan Haizatul Aisyhah Wan

    2018-03-01

    The rate of global deforestation and its impact on the environment has led particle board manufacture to search for alternative feedstock, especially in countries where wood is less available compared to other cellulosic natural product. Based on the properties of coconut fibre and PET bottle, these two materials can be recycle as raw material for manufacture of panel board. As for this study, the coconut fibre were used as the filler and PET bottle as outer lining of the panel board. Two types of coconut fibre were used which are grinding and un-grinding coconut fibre. At first, the coconut fibre are undergoes softening, grinding, drying and sieving process, while PET bottle was cleaning, shredding, sieving before compacted using hydraulic hot press machine. There are four types of testing that been carried out which are swelling, water absorption, Modulus of Elasticity (MOE) and Modulus of Rupture (MOR). The result show the conventional board has the highest value for MOE test, so it's indicate that the conventional board is less strength from the coconut fibre board. As for water absorption test, the average water absorption of coconut fibre based panel board is less than conventional board. Overall, the coconut fibre board is better than conventional panel board because coconut fibre board are less swelling, has low water absorption, high modulus of rupture and low modulus of elasticity. Based on the finding, this coconut fibre panel board has potential as a stronger and long-lasting panel board than the conventional board in the market. Other than that, the panel also have their own aesthetic value since the recycled plastic bottle used as outer lining is colourful and giving aesthetic value.

  13. Characterization of crystallinity in PET bottles by IR spectroscopy

    NASA Astrophysics Data System (ADS)

    Nguyen, Tuan Q.; Christopher, Plummer J. G.

    2000-03-01

    PET is a semicrystalline thermoplastic widely used to package foods and beverages. Most of these applications rely on the barrier properties of the polymer, which improve with the proportion of crystalline phase. It is therefore important for the industries concerned to develop a fast, simple and reliable technique to quantify the degree of crystallization. Current FTIR and Raman spectroscopy correlate cristallinity with the trans to gauche ratio of the ethylene conformational isomers. Such a procedure, however, is based on the naive assumption that the proportion of trans isomers in the crystalline regions and that of the trans/gauche isomers in the amorphous regions vary linearly with the total crystallinity. By combining density measurements with DSC, WAXS and FTIR, we have shown the conformer technique to work well for isotropic PET sheets, but not for bottles. Biaxial extension of the preform during processing results in strain-induced cristallinity with a different morphology to that induced thermally. As a result, PET should be treated as a three-component mixture with distinct physical and spectroscopic properties for each phase. Using ATR, micro-transmission FTIR and factor analysis, our primary goal has been to develop a routine technique which allows one to identify the contribution of each component in the spectra of commercial PET bottles.

  14. Effects of storage temperature and time of antimony release from PET bottles into drinking water in China.

    PubMed

    Qiao, Fei; Lei, Kun; Li, Zicheng; Liu, Qing; Wei, Zhanliang; An, Lihui; Qi, Hongli; Cui, Song

    2018-01-01

    Antimony (Sb) concentrations were measured in 10 brands of PET bottled drinking water available in supermarkets in China. To simulate general storage habits based on market research, these PET bottles with drinking water were stored for 4 weeks in a lab or a car trunk during the summer. Although the PET package material of brand A had the lowest Sb level (142.71 ± 29.81 μg/g), it showed a significant increase in Sb concentrations when stored in both the car trunk and the lab. There was significant release of Sb from the PET bottles into the water following 24 h of incubation at ≥ 40 °C (40, 50, 60, and 70 °C), especially at 70 °C. The potential health risk of Sb release from PET bottles was calculated based on daily intake values and determined to be acceptable for consumers under normal storage conditions.

  15. Study on heat transfer coefficients during cooling of PET bottles for food beverages

    NASA Astrophysics Data System (ADS)

    Liga, Antonio; Montesanto, Salvatore; Mannella, Gianluca A.; La Carrubba, Vincenzo; Brucato, Valerio; Cammalleri, Marco

    2016-08-01

    The heat transfer properties of different cooling systems dealing with Poly-Ethylene-Terephthalate (PET) bottles were investigated. The heat transfer coefficient (Ug) was measured in various fluid dynamic conditions. Cooling media were either air or water. It was shown that heat transfer coefficients are strongly affected by fluid dynamics conditions, and range from 10 W/m2 K to nearly 400 W/m2 K. PET bottle thickness effect on Ug was shown to become relevant under faster fluid dynamics regimes.

  16. Silicon oxide permeation barrier coating of PET bottles and foils

    NASA Astrophysics Data System (ADS)

    Steves, Simon; Deilmann, Michael; Awakowicz, Peter

    2009-10-01

    Modern packaging materials such as polyethylene terephthalate (PET) have displaced established materials in many areas of food and beverage packaging. Plastic packing materials offer are various advantages concerning production and handling. PET bottles for instance are non-breakable and lightweight compared to glass and metal containers. However, PET offers poor barrier properties against gas permeation. Therefore, the shelf live of packaged food is reduced. Permeation of gases can be reduced by depositing transparent plasma polymerized silicon oxide (SiOx) barrier coatings. A microwave (2.45 GHz) driven low pressure plasma reactor is developed based on a modified Plasmaline antenna to treat PET foils or bottles. To increase the barrier properties of the coatings furthermore a RF substrate bias (13.56 MHz) is applied. The composition of the coatings is analyzed by means of Fourier transform infrared (FTIR) spectroscopy regarding carbon and hydrogen content. Influence of gas phase composition and substrate bias on chemical composition of the coatings is discussed. A strong relation between barrier properties and film composition is found: good oxygen barriers are observed as carbon content is reduced and films become quartz-like. Regarding oxygen permeation a barrier improvement factor (BIF) of 70 is achieved.

  17. Comparative evolution of oxygen, carbon dioxide, nitrogen, and sulfites during storage of a rosé wine bottled in PET and glass.

    PubMed

    Toussaint, Marie; Vidal, Jean-Claude; Salmon, Jean-Michel

    2014-04-02

    The management of dissolved and headspace gases during bottling and the choice of packaging are both key factors for the shelf life of wine. Two kinds of 75 cL polyethylene terephthalate (PET) bottles (with or without recycled PET) were compared to glass bottles filled with a rosé wine, closed with the same screwcaps and stored upright at 20 °C in light or in the dark. Analytical monitoring (aphrometric pressure, headspace volume, O2, N2, CO2, and SO2) was carried out for 372 days. After the consumption of O2 trapped during bottling, the total O2 content in glass bottles remained stable. A substantial decrease of CO2 and SO2 concentration and an increase of O2 concentration were observed in the PET bottles after 6 months because of the considerable gas permeability of monolayer PET. Light accelerated O2 consumption during the early months. Finally, the kinetic monitoring of partial pressures in gas and liquid phases in bottles showed contrasting behavior of O2 and N2 in comparison with CO2.

  18. Migration of antimony from PET bottles into beverages: determination of the activation energy of diffusion and migration modelling compared with literature data.

    PubMed

    Welle, F; Franz, R

    2011-01-01

    Plastics bottles made from polyethylene terephthalate (PET) are increasingly used for soft drinks, mineral water, juices and beer. In this study a literature review is presented concerning antimony levels found both in PET materials as well as in foods and food simulants. On the other hand, 67 PET samples from the European bottle market were investigated for their residual antimony concentrations. A mean value of 224 ± 32 mg kg(-1) was found, the median was 220 mg kg(-1). Diffusion coefficients for antimony in PET bottle materials were experimentally determined at different temperature between 105 and 150°C. From these data, the activation energy of diffusion for antimony species from the PET bottle wall into beverages and food simulants was calculated. The obtained value of 189 kJ mol(-1) was found to be in good agreement with published data on PET microwave trays (184 kJ mol(-1)). Based on these results, the migration of antimony into beverages was predicted by mathematical migration modelling for different surface/volume ratios and antimony bottle wall concentrations. The results were compared with literature data as well as international legal limits and guidelines values for drinking water and the migration limit set from food packaging legislation. It was concluded that antimony levels in beverages due to migration from PET bottles manufactured according to the state of the art can never reach or exceed the European-specific migration limit of 40 microg kg(-1). Maximum migration levels caused by room-temperature storage even after 3 years will never be essentially higher than 2.5 microg kg(-1) and in any case will be below the European limit of 5 microg kg(-1) for drinking water. The results of this study confirm that the exposure of the consumer by antimony migration from PET bottles into beverages and even into edible oils reaches approximately 1% of the current tolerable daily intake (TDI) established by World Health Organisation (WHO). Having

  19. An evaluation of the migration of antimony from polyethylene terephthalate (PET) plastic used for bottled drinking water.

    PubMed

    Chapa-Martínez, C A; Hinojosa-Reyes, L; Hernández-Ramírez, A; Ruiz-Ruiz, E; Maya-Treviño, L; Guzmán-Mar, J L

    2016-09-15

    The leaching of antimony (Sb) from polyethylene terephthalate (PET) bottling material was assessed in twelve brands of bottled water purchased in Mexican supermarkets by atomic fluorescence spectrometry with a hydride generation system (HG-AFS). Dowex® 1X8-100 ion-exchange resin was used to preconcentrate trace amounts of Sb in water samples. Migration experiments from the PET bottle material were performed in water according to the following storage conditions: 1) temperature (25 and 75°C), 2) pH (3 and 7) and 3) exposure time (5 and 15days), using ultrapure water as a simulant for liquid foods. The test conditions were studied by a 2(3) factorial experimental design. The Sb concentration measured in the PET packaging materials varied between 73.0 and 111.3mg/kg. The Sb concentration (0.28-2.30μg/L) in all of the PET bottled drinking water samples examined at the initial stage of the study was below the maximum contaminant level of 5μg/L prescribed by European Union (EU) regulations. The parameters studied (pH, temperature, and storage time) significantly affected the release of Sb, with temperature having the highest positive significant effect within the studied experimental domain. The highest Sb concentration leached from PET containers was in water samples at pH7 stored at 75°C for a period of 5days. The extent of Sb leaching from the PET ingredients for different brands of drinking water can differ by as much as one order of magnitude in experiments conducted under the worst-case conditions. The chronic daily intake (CDI) caused by the release of Sb in one brand exceeded the Environmental Protection Agency (USEPA) regulated CDI value of 400ng/kg/day, with values of 514.3 and 566.2ng/kg/day for adults and children. Thus, the appropriate selection of the polymer used for the production of PET bottles seems to ensure low Sb levels in water samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Accessories modifying based on plastic waste of shampoo bottle as home economic product

    NASA Astrophysics Data System (ADS)

    Setyowati, Erna; Sukesi, Siti

    2018-03-01

    Plastic is a waste that can not decompose by the soil and if its left without a good handling can pollute the environment. Plastic waste needs processing by the recycle bottles principle. Shampoo bottle is one of plastic waste with high density polyethylene type (HDPE). One of the innovation to recycling shampoo bottles waste into the new products whichbeneficially and aestheticallyform by engineered the buns accesories. Accessories are one of the tools used by most women, in the form of trinkets or ornaments which ajusted to the trend to beautify the look. Accessories from shampoo bottle waste can be obtained from household waste, beauty salon and the beauty program study by inculcating human beings' behavior by transforming waste into blessing while also increasing family income. Technique of making its by compiling through improvement of panelist team. The goal of this research is to engineering theaccessories based on shampoo bottle waste as home economics. The method are using experiment, observation and documentation, analysis using descriptive. The results obtained from the overall sensory test averaged at 93%, while the favored test averaged at 85.5%. The product can be ordered according to the desired design, but it takes a long time. Therefore accessories engineering from shampoo bottles waste-based can be used as home economics. The production of shampoo bottles waste-based accessories should improved its quality and quantity, to be marketed through the community, by the cooperation with accessories and bun craftsmen.

  1. Field comparison of solar water disinfection (SODIS) efficacy between glass and polyethylene terephalate (PET) plastic bottles under sub-Saharan weather conditions.

    PubMed

    Asiimwe, J K; Quilty, B; Muyanja, C K; McGuigan, K G

    2013-12-01

    Concerns about photodegradation products leaching from plastic bottle material into water during solar water disinfection (SODIS) are a major psychological barrier to increased uptake of SODIS. In this study, a comparison of SODIS efficacy using glass and plastic polyethylene terephalate (PET) bottles was carried out under strong real sunlight and overcast weather conditions at Makerere University in central Uganda. Both clear and turbid natural water samples from shallow wells and open dug wells, respectively, were used. Efficacy was determined from the inactivation of a wild strain of Escherichia coli in solar-exposed contaminated water in both glass and PET bottles. The studies reveal no significant difference in SODIS inactivation between glass and PET bottles (95% CI, p > 0.05), for all water samples under the different weather conditions except for clear water under overcast conditions where there was a small but significant difference (95% CI, p = 0.047) with less viable bacterial counts in PET bottles at two intermediate time points but not at the end of the exposure. The results demonstrate that SODIS efficacy in glass under tropical field conditions is comparable to PET plastic. SODIS users in these regions can choose either of reactors depending on availability and preference of the user.

  2. The degradation potential of PET bottles in the marine environment: An ATR-FTIR based approach

    NASA Astrophysics Data System (ADS)

    Ioakeimidis, C.; Fotopoulou, K. N.; Karapanagioti, H. K.; Geraga, M.; Zeri, C.; Papathanassiou, E.; Galgani, F.; Papatheodorou, G.

    2016-03-01

    The dominance and persistence of plastic debris in the marine environment are well documented. No information exists in respect to their lifespan in the marine environment. Nevertheless, the degradation potential of plastic litter items remains a critical issue for marine litter research. In the present study, polyethylene terephthalate bottles (PETs) collected from the submarine environment were characterized using ATR-FTIR in respect to their degradation potential attributed to environmental conditions. A temporal indication was used as indicative to the years of presence of the PETs in the environment as debris. PETs seem to remain robust for approximately fifteen years. Afterwards, a significant decrease of the native functional groups was recorded; some even disappear; or new-not typical for PETs-are created. At a later stage, using the PET time series collected from the Saronikos Gulf (Aegean Sea-E. Mediterranean), it was possible to date bottles that were collected from the bottom of the Ionian Sea (W. Greece). It is the first time that such a study has been conducted with samples that were actually degraded in the marine environment.

  3. Comparative life cycle assessment and life cycle costing of four disposal scenarios for used polyethylene terephthalate bottles in Mauritius.

    PubMed

    Foolmaun, Rajendra Kumar; Ramjeeawon, Toolseeram

    2012-09-01

    The annual rise in population growth coupled with the flourishing tourism industry in Mauritius has lead to a considerable increase in the amount of solid waste generated. In parallel, the disposal of non-biodegradable wastes, especially plastic packaging and plastic bottles, has also shown a steady rise. Improper disposal of used polyethylene terephthalate (PET) bottles constitutes an eyesore to the environmental landscape and is a threat to the flourishing tourism industry. It is of utmost importance, therefore, to determine a suitable disposal method for used PET bottles which is not only environmentally efficient but is also cost effective. This study investigated the environmental impacts and the cost effectiveness of four selected disposal alternatives for used PET bottles in Mauritius. The four disposal routes investigated were: 100% landfilling; 75% incineration with energy recovery and 25% landfilling; 40% flake production (partial recycling) and 60% landfilling; and 75% flake production and 25% landfilling. Environmental impacts of the disposal alternatives were determined using ISO standardized life cycle assessment (LCA) and with the support of SimaPro 7.1 software. Cost effectiveness was determined using life cycle costing (LCC). Collected data were entered into a constructed Excel-based model to calculate the different cost categories, Net present values, damage costs and payback periods. LCA and LCC results indicated that 75% flake production and 25% landfilling was the most environmentally efficient and cost-effective disposal route for used PET bottles in Mauritius.

  4. Waste management through life cycle assessment of products

    NASA Astrophysics Data System (ADS)

    Borodin, Yu V.; Aliferova, T. E.; Ncube, A.

    2015-04-01

    The rapid growth of a population in a country can contribute to high production of waste. Municipal waste and industrial waste can bring unhealthy and unpleasant environment or even diseases to human beings if the wastes are not managed properly.With increasing concerns over waste and the need for ‘greener’ products, it is necessary to carry out Life Cycle Assessments of products and this will help manufacturers take the first steps towards greener designs by assessing their product's carbon output. Life Cycle Assessment (LCA) is a process to evaluate the environmental burdens associated with a product, process or activity by identifying and quantifying energy and materials used and wastes released to the environment, and to assess the impact of those energy and material used and released to the environment. The aim of the study was to use a life cycle assessment approach to determine which waste disposal options that will substantially reduce the environmental burdens posed by the Polyethylene Terephthalate (PET) bottle. Several important observations can be made. 1) Recycling of the PET bottle waste can significantly reduce the energy required across the life cycle because the high energy inputs needed to process the requisite virgin materials greatly exceeds the energy needs of the recycling process steps. 2) Greenhouse gases can be reduced by opting for recycling instead of landfilling and incineration. 3) Quantity of waste emissions released from different disposal options was identified. 4) Recycling is the environmentally preferable disposal method for the PET bottle. Industry can use the tools and data in this study to evaluate the health, environmental, and energy implications of the PET bottle. LCA intends to aid decision-makers in this respect, provided that the scientific underpinning is available. Strategic incentives for product development and life cycle management can then be developed.

  5. Life cycle assessment of bottled water: A case study of Green2O products.

    PubMed

    Horowitz, Naomi; Frago, Jessica; Mu, Dongyan

    2018-06-01

    This study conducted a full life cycle analysis of bottled water on four types of bottles: ENSO, PLA (corn based), recycled PET, and regular (petroleum based) PET, to discern which bottle material is more beneficial to use in terms of environmental impacts. PET bottles are the conventional bottles used that are not biodegradable and accumulate in landfills. PLA corn based bottles are derived from an organic substance and are degradable under certain environmental conditions. Recycled PET bottles are purified PET bottles that were disposed of and are used in a closed loop system. An ENSO bottle contains a special additive which is designed to help the plastic bottle degrade after disposed of in a landfill. The results showed that of all fourteen impact categories examined, the recycled PET and ENSO bottles were generally better than the PLA and regular PET bottles; however, the ENSO had the highest impacts in the categories of global warming and respiratory organics, and the recycled PET had the highest impact in the eutrophication category. The life cycle stages that were found to have the highest environmental impacts were the bottle manufacturing stage and the bottled water distribution to storage stage. Analysis of the mixed bottle material based on recycled PET resin and regular PET resin was discussed as well, in which key impact categories were identified. The PLA bottle contained extremely low impacts in the carcinogens, respiratory organics and global warming categories, yet it still contained the highest impacts in seven of the fourteen categories. Overall, the results demonstrate that the usage of more sustainable bottles, such as biodegradable ENSO bottles and recycled PET bottles, appears to be a viable option for decreasing impacts of the bottled water industry on the environment. Published by Elsevier Ltd.

  6. Optimization of fixed titanium dioxide film on PET bottles and visual indicator for water disinfection

    NASA Astrophysics Data System (ADS)

    Heredia-Munoz, Manuel Antonio

    Water is perhaps the most important resource that sustains human life. According to the World Health Organization (WHO), almost two billion people do not have access to the required water that is needed to satisfy their daily needs and one billion do not have access to clean sources of water for consumption, most of them living in isolated and poor areas around the globe. Poor quality water increases the risk of cholera, typhoid fever and dysentery, and other water-borne illness making this problem a real crisis that humankind is facing. Several water disinfection technologies have been proposed as solutions for this problem. Solar water disinfection using TiO2 coated PET bottles was the alternative that is studied in this work. This technology does not only inactivate bacteria but also disintegrates organic chemicals that can be present in water. The objectives of this work address the optimization of the TiO 2 coated PET bottles technologies. The improvement on the bottle coating process, using two coats of 10% W/V of TiO2 in a solution of vinegar and sodium bicarbonate to form the TiO2 film, the use of a different indigo carmine (1.25 X 10-1mg/pill) concentration in the pill indicator of contamination, the increase of the disinfection rate through shaking the bottles, degradation under intermittent UV radiation and the effect of bottle size on photocatalytic water disinfection were among the most important findings. A new mathematical model that describes better photocatalytic water disinfection in TiO2 coated bottles and simulates water disinfection under different working conditions was another important achievement. These results can now be used to design a strategy for disseminating this technology in areas where it is required and, in that way, generate the greatest positive impact on the people needing safe drinking water.

  7. Treatment of Bottled Liquid Waste During Remediation of the Hanford 618-10 Burial Ground - 13001

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Faulk, Darrin E.; Pearson, Chris M.; Vedder, Barry L.

    2013-07-01

    A problematic waste form encountered during remediation of the Hanford Site 618-10 burial ground consists of bottled aqueous waste potentially contaminated with regulated metals. The liquid waste requires stabilization prior to landfill disposal. Prior remediation activities at other Hanford burial grounds resulted in a standard process for sampling and analyzing liquid waste using manual methods. Due to the highly dispersible characteristics of alpha contamination, and the potential for shock sensitive chemicals, a different method for bottle processing was needed for the 618-10 burial ground. Discussions with the United States Department of Energy (DOE) and United States Environmental Protection Agency (EPA)more » led to development of a modified approach. The modified approach involves treatment of liquid waste in bottles, up to one gallon per bottle, in a tray or box within the excavation of the remediation site. Bottles are placed in the box, covered with soil and fixative, crushed, and mixed with a Portland cement grout. The potential hazards of the liquid waste preclude sampling prior to treatment. Post treatment verification sampling is performed to demonstrate compliance with land disposal restrictions and disposal facility acceptance criteria. (authors)« less

  8. HPLC study of migration of terephthalic acid and isophthalic acid from PET bottles into edible oils.

    PubMed

    Khaneghah, Amin Mousavi; Limbo, Sara; Shoeibi, Shahram; Mazinani, Somayeh

    2014-08-01

    Polyethylene terephthalate (PET) containers for food oil packaging were evaluated with a newly established determination method for terephthalic acid (TPA) and isophthalic acid (IPA). The analysis of monomers, TPA and IPA that migrate from PET bottles into oils was performed using high-pressure liquid chromatography with a diode array detector. Three types of commercial oils (sunflower oil, canola oil and blended oil which included sunflower oil, soy bean oil and cottonseed oil) were bottled in PET containers. These samples were incubated for 10 days at 49 °C as accelerated test condition. The means of recovery for this method varied from 70% to 72% and from 101% to 111% for TPA and IPA, respectively. The results showed that the amounts of specific migration of TPA and IPA into the samples conform to European Union legislation that identifies specific migration limits. More important, the results highlighted a different behavior of migration as a function of the fatty acid profile. Previous investigations have been performed with food simulants such as HB307 or 20% ethanol but our study used real food samples and determined trace amounts of the migrated compounds. Further investigation will be needed to better explain the influence of fatty acid conformation on migration of PET monomers. © 2013 Society of Chemical Industry.

  9. Water Quality Evaluation of PET Bottled Water by Mineral Balance in the Northeast Asian Region: A Case Study of South Korea.

    PubMed

    Houri, Daisuke; Koo, Chung Mo

    2015-09-01

    The past few years have seen a demand for drinking water in contemporary society with a focus on safety and taste. Mineral water is now marketed as a popular commercial product and, partly due to health concerns, the production. For the study, a comparison was carried out of water samples from 9 types of polyethylene terephthalate (PET) bottled water sold in South Korea as well as from tap water in the cities of Seoul and Chuncheon. These were compared with samples of Japanese PET bottled water in order to determine shared commonalities and identify individual characteristics. To evaluate water quality objectively, we quantified the elements contained in the water samples. Samples were assessed not with the usual sensory evaluation but with the evaluation approach advocated by Hashimoto et al. which employs the Water Index of Taste and the Water Index of Health. The levels of water quality obtained were compared with the "Prerequisites for Tasty Water" and the "Standards for Tasty Water" devised for city water. The PET Bottled water varieties analyzed in this study-Seoksu, Icis, Bong Pyong, Soon Soo 100, Dong Won Saem Mul, GI JANG SOO and DIAMOND-showed the Water Index of Taste ≥ 2.0 and the Water Index of Health ≥ 5.2, which we classified as tasty/healthy water. SamDaSoo and NamiNeral can be classified as tasty water due to their values of the Water Index of Taste ≥ 2.0 and the Water Index of Health < 5.2. The South Korean PET bottled water studied here fulfills the "Water Index of Taste," "Water Index of Health," "Standard for Tasty Water" and "Prerequisites for Tasty Water" that Japanese people value for city water. We can conclude that bottled water which meets water quality requirements will be considered good-tasting by a majority of people.

  10. Effect of sunlight exposure on the release of intentionally and/or non-intentionally added substances from polyethylene terephthalate (PET) bottles into water: chemical analysis and in vitro toxicity.

    PubMed

    Bach, Cristina; Dauchy, Xavier; Severin, Isabelle; Munoz, Jean-François; Etienne, Serge; Chagnon, Marie-Christine

    2014-11-01

    The effect of sunlight exposure on chemical migration into PET-bottled waters was investigated. Bottled waters were exposed to natural sunlight for 2, 6 and 10 days. Migration was dependent on the type of water. Formaldehyde, acetaldehyde and Sb migration increased with sunlight exposure in ultrapure water. In carbonated waters, carbon dioxide promoted migration and only formaldehyde increased slightly due to sunlight. Since no aldehydes were detected in non-carbonated waters, we conclude that sunlight exposure has no effect. Concerning Sb, its migration levels were higher in carbonated waters. No unpredictable NIAS were identified in PET-bottled water extracts. Cyto-genotoxicity (Ames and micronucleus assays) and potential endocrine disruption effects (transcriptional-reporter gene assays) were checked in bottled water extracts using bacteria (Salmonella typhimurium) and human cell lines (HepG2 and MDA-MB453-kb2). PET-bottled water extracts did not induce any toxic effects (cyto-genotoxicity, estrogenic or anti-androgenic activity) in vitro at relevant consumer-exposure levels. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. LCA of waste prevention activities: a case study for drinking water in Italy.

    PubMed

    Nessi, Simone; Rigamonti, Lucia; Grosso, Mario

    2012-10-15

    The strategic relevance of waste prevention has considerably increased worldwide during recent years, such that the current European legislation requires the preparation of national waste prevention programmes in which reduction objectives and measures are identified. In such a context, it is possible to recognise how, in order to correctly evaluate the environmental consequences of a prevention activity, a life cycle perspective should be employed. This allows us to go beyond the simple reduction of the generated waste which, alone, does not automatically imply achieving better overall environmental performance, especially when this reduction is not pursued through the simple reduction of consumption. In this study, the energetic and environmental performance of two waste prevention activities considered particularly meaningful for the Italian context were evaluated using life cycle assessment (LCA) methodology. The two activities were the utilisation of public network water (two scenarios) and of refillable bottled water (two scenarios) for drinking purposes, instead of one-way bottled water (three scenarios). The energy demand and specific potential impacts of the four waste prevention scenarios and of the three baseline scenarios were compared with the aim of evaluating whether, and under what conditions, the analysed prevention activities are actually associated with overall energetic and environmental benefits. In typical conditions, the use of public network water directly from the tap results in the best scenario, while if water is withdrawn from public fountains, its further transportation by private car can involve significant impacts. The use of refillable PET bottled water seems the preferable scenario for packaged water consumption, if refillable bottles are transported to local distributors along the same (or a lower) distance as one-way bottles to retailers. The use of refillable glass bottled water is preferable to one-way bottled water only if a

  12. Water Quality Evaluation of PET Bottled Water by Mineral Balance in the Northeast Asian Region: A Case Study of South Korea

    PubMed Central

    Houri, Daisuke; Koo, Chung Mo

    2015-01-01

    Background The past few years have seen a demand for drinking water in contemporary society with a focus on safety and taste. Mineral water is now marketed as a popular commercial product and, partly due to health concerns, the production. Methods For the study, a comparison was carried out of water samples from 9 types of polyethylene terephthalate (PET) bottled water sold in South Korea as well as from tap water in the cities of Seoul and Chuncheon. These were compared with samples of Japanese PET bottled water in order to determine shared commonalities and identify individual characteristics. To evaluate water quality objectively, we quantified the elements contained in the water samples. Samples were assessed not with the usual sensory evaluation but with the evaluation approach advocated by Hashimoto et al. which employs the Water Index of Taste and the Water Index of Health. The levels of water quality obtained were compared with the “Prerequisites for Tasty Water” and the “Standards for Tasty Water” devised for city water. Results The PET Bottled water varieties analyzed in this study—Seoksu, Icis, Bong Pyong, Soon Soo 100, Dong Won Saem Mul, GI JANG SOO and DIAMOND—showed the Water Index of Taste ≥ 2.0 and the Water Index of Health ≥ 5.2, which we classified as tasty/healthy water. SamDaSoo and NamiNeral can be classified as tasty water due to their values of the Water Index of Taste ≥ 2.0 and the Water Index of Health < 5.2. Conclusion The South Korean PET bottled water studied here fulfills the “Water Index of Taste,” “Water Index of Health,” “Standard for Tasty Water” and “Prerequisites for Tasty Water” that Japanese people value for city water. We can conclude that bottled water which meets water quality requirements will be considered good-tasting by a majority of people. PMID:26538797

  13. Measuring the significance of pearlescence in real-time bottle forming

    NASA Astrophysics Data System (ADS)

    Nixon, J.; Menary, G.; Yan, S.

    2018-05-01

    This work examines the optical properties of polyethylene terephthalate (PET) bottles during the stretch-blow-moulding (SBM) process. PET has a relatively large process window with regards to process parameters, however if the boundaries are pushed, the resultant bottle can become insufficient for consumer requirements. One aspect of this process is the onset of pearlescence in the bottle material, where the bottle becomes opaque due to elevated stress whitening. Experimental trials were carried out using a modified free-stretch-blow machine where the deforming bottle was examined in free air. The strain values of the deformation were measured using digital image correlation (DIC) and the optical properties were measured relative to the initial amorphous PET preform. The results reveal that process parameters can significantly affect pearlescence. The detrimental level of pearlescence may be predicted therefore reducing the probability of poorly formed bottles.

  14. Identification of chemicals, possibly originating from misuse of refillable PET bottles, responsible for consumer complaints about off-odours in water and soft drinks.

    PubMed

    Widén, H; Leufvén, A; Nielsen, T

    2005-07-01

    Mineral water and soft drinks with a perceptible off-odour were analysed to identify contaminants originating from previous misuse of the refillable polyethylene terephthalate (PET) bottle. Consumers detected the off-odour after opening the bottle and duly returned it with the remaining content to the producers. The contaminants in question had thus been undetected by the in-line detection devices (so-called 'sniffers') that are supposed to reject misused bottles. GC-MS analysis was carried out on the headspace of 31 returned products and their corresponding reference products, and chromatograms were compared to find the possible off-odour compounds. Substances believed to be responsible for the organoleptic change were 2-methoxynaphthalene (10 bottles), dimethyl disulfide (4), anethole (3), petroleum products (4), ethanol with isoamyl alcohol (1) and a series of ethers (1). The mouldy/musty odour (5 bottles) was caused by trichloroanisole in one instance. In some cases, the origins of the off-odours are believed to be previous consumer misuse of food products (liquorice-flavoured alcohol, home-made alcohol containing fusel oil) or non-food products (cleaning products, petroleum products, oral moist snuff and others). The results also apply to 1.5-litre recyclable PET bottles, since the nature and extent of consumer misuse can be expected to be similar for the two bottle types.

  15. Small-sized microplastics and pigmented particles in bottled mineral water.

    PubMed

    Oßmann, Barbara E; Sarau, George; Holtmannspötter, Heinrich; Pischetsrieder, Monika; Christiansen, Silke H; Dicke, Wilhelm

    2018-09-15

    Up to now, only a few studies about microparticle contamination of bottled mineral water have been published. The smallest analysed particle size was 5 μm. However, due to toxicological reasons, especially microparticles smaller than 1.5 μm are critically discussed. Therefore, in the present study, 32 samples of bottled mineral water were investigated for contamination by microplastics, pigment and additive particles. Due to the application of aluminium coated polycarbonate membrane filters and micro-Raman spectroscopy, a lowest analysed particle size of 1 μm was achieved. Microplastics were found in water from all bottle types: in single use and reusable bottles made of poly(ethylene terephthalate) (PET) as well as in glass bottles. The amount of microplastics in mineral water varied from 2649 ± 2857 per litre in single use PET bottles up to 6292 ± 10521 per litre in glass bottles. While in plastic bottles, the predominant polymer type was PET; in glass bottles various polymers such as polyethylene or styrene-butadiene-copolymer were found. Hence, besides the packaging itself, other contamination sources have to be considered. Pigment particles were detected in high amounts in reusable, paper labelled bottles (195047 ± 330810 pigment particles per litre in glass and 23594 ± 25518 pigment particles per litre in reusable paper labelled PET bottles). Pigment types found in water samples were the same as used for label printing, indicating the bottle cleaning process as possible contamination route. Furthermore, on average 708 ± 1024 particles per litre of the additive Tris(2,4-di-tert-butylphenyl)phosphite were found in reusable PET bottles. This additive might be leached out from the bottle material itself. Over 90% of the detected microplastics and pigment particles were smaller than 5 μm and thus not covered by previous studies. In summary, this is the first study reporting about microplastics, pigment and additive particles

  16. Impact of temperature and storage time on the migration of antimony from polyethylene terephthalate (PET) containers into bottled water in Qatar.

    PubMed

    Al-Otoum, Fatima; Al-Ghouti, Mohammad A; Costa, Ozeas S; Khraisheh, Majeda

    2017-11-12

    Prosperity in Qatar and the consequent stresses on water resources resulted in a sustainable increase in the bottled drinking water market. Reports on health concerns and possible migration of chemicals from the plastic material into the water have driven the current investigation. This study aims to address the extent of antimony (Sb) leaching from polyethylene terephthalate (PET) water bottles subject to temperature variations (24-50 °C) due to Qatar's hot climate and improper storage conditions. A representative basket including 66 different imported and locally produced water bottles was considered. The concentrations of Sb in bottled water ranged from 0.168 to 2.263 μg/L at 24 °C and from 0.240 to 6.110 μg/L at 50 °C. Antimony concentrations in PET bottles at 24 °C was significantly lower than those at 50 °C (p = 0.0142), indicating that the temperature was a principal factor affecting the release of Sb from the plastic into the water. Although the detected Sb amounts were below the guidelines endorsed by WHO and Qatar (standard 5 μg/L) at 24 °C, the concentration measured at 50 °C was higher than the recommended WHO values (6.11 μg/L).

  17. Carbonized waste for the cut-down of environmental pollution with heavy metals

    NASA Astrophysics Data System (ADS)

    Gmucová, K.; Morvová, M.; Havránek, E.; Kliman, J.; Košinár, I.; Kunecová, D.; Malakhov, A. I.; Anisimov, Yu. S.; Morva, I.; Siváček, I.; Sýkorová, M.; Šatka, A.

    2011-07-01

    Nowadays, an increasing concern about the treatment and disposal of waters contaminated by toxic heavy metals is noticed. The toxic pollutants must be removed from the sewage water which then is fed back into the materials cycle. Any candidate technology should result in reusable by-products. With this in mind, the aim of the present study is to test a low cost procedure for utilization of the carbonized waste, a product of PET (polyethylene terephthalate) bottles pyrolysis on sand bedding, for this purpose. Both the water present in PET bottles waste and combustion exhaust probably contribute to the conversion of carbon char to activated carbon directly within the pyrolysis oven. Preliminary results, obtained for several heavy metal ions under laboratory conditions are presented and discussed. Adsorption of heavy metals on the carbonized PET waste is tested by both the electrochemical methods and X-ray fluorescence spectrometry. A simple desorption procedure for the regeneration of prepared active carbon is proposed.

  18. Recycling of plastic wastes with poly (ethylene-co-methacrylic acid) copolymer as compatibilizer and their conversion into high-end product.

    PubMed

    Rajasekaran, Divya; Maji, Pradip K

    2018-04-01

    This paper deals with the utilization of plastic wastes to a useful product. The major plastic pollutants that are considered to be in maximum use i.e. PET bottle and PE bags have been taken for consideration for recycling. As these two plastic wastes are not compatible, poly (ethylene-co-methacrylic acid) copolymer has been used as compatibilizer to process these two plastic wastes. Effect of dose of poly (ethylene-co-methacrylic acid) copolymer as compatibilizer has been studied here. It has been shown that only 3 wt% of poly (ethylene-co-methacrylic acid) copolymer is sufficient to make 3:1 mass ratio of PET bottle and polyethylene bags compatible. Compatibility has been examined through mechanical testing, thermal and morphological analysis. After analysing the property of recyclates, better mechanical and thermal property has been observed. Almost 500% of tensile property has been improved by addition of 3 wt% of poly (ethylene-co-methacrylic acid) copolymer in 3:1 mass ratio blend of PET bottle and PE bags than that of pristine blend. Morphological analysis by FESEM and AFM has also confirmed the compatibility of the blend. Experimental data showed better performance than available recycling process. Copyright © 2018 Elsevier Ltd. All rights reserved.

  19. Synthesis of silica gel from waste glass bottles and its application for the reduction of free fatty acid (FFA) on waste cooking oil

    NASA Astrophysics Data System (ADS)

    Sudjarwo, Wisnu Arfian A.; Bee, Mei Magdayanti F.

    2017-06-01

    Synthesis of silica gel from waste glass bottles was conducted with aims to characterize the product and to analyze its application forthe reduction of free fatty acid (FFA) on waste cooking oil. Silica source taken from waste glass bottles was synthesized into silica gel by using the sol-gel method. Several types of silica gel were produced with three different weight ratios of waste glass and sodium hydroxide as an extractor. They were: 1:1, 1:2, and 1:3. The results indicated that synthesized silica possessed morphology innano-sizedranging from 85 nm to 459 nm. Adsorption performance was investigated by a batch system atthe temperature between 70°C and 110°C by a range of 10°C in an hour. Analysis of the adsorption characteristic showed that the highest efficiency value of FFA reduction of 91% was obtained by silica gel with ratiosof 1:1 (SG 1) and 1:3 (SG 3). Their performances were also followed by the decline of the refractive index and the density of waste cooking oil.

  20. Composite material making from empty fruit bunches of palm oil (EFB) and Ijuk (Arengapinnata) using plastic bottle waste as adhesives

    NASA Astrophysics Data System (ADS)

    Rihayat, T.; Salim, S.; Audina, N.; Khan, N. S. P.; Zaimahwati; Sami, M.; Yunus, M.; Salisah, Z.; Alam, P. N.; Saifuddin; Yusuf, I.

    2018-03-01

    Reviewed from the current technological required a new methods to capable offering a high profit value without overriding the quality. The development of composite technology is now beginning to shift from traditional composite materials based petroleum to natural fibers composite. In the present study, aim to made specimens using natural fibers in form of EFB as a composite reinforcedment with Polyethylene Terephtalate (PET) derived from Plastic bottles waste as matrix with mixed composition parameters and time-tolerance in the mixing process to build a biocomposite material. The characterization of mechanical properties includes tensile test (ASTM D638-01) and bending test (ASTM D790-02) followed by thermal analysis using Thermogravimetric Analysis (TGA), and morphological analysis using scanning electron microscope (SEM). The analysis effect of EFB, Ijuk and PET mixtures on the composite matrix is very influential with mechanical properties characterization, including tensile test and bending strength. The results demonstrated that from the sample named : 50 : 25: 25, hybrid composites showed improved properties such as tensile strength of 167 MPa while the 90:05:05 based composites exhibited tensile strength values of 30 MPa, respectively. In term the flexural test the best result of composition on the properties with 10 minutes duration time its load value 7,5 Mpa for 80:10:10.

  1. Study on mechanical and physical properties of composite materials with recycled PET as fillers for paving block application

    NASA Astrophysics Data System (ADS)

    Wicaksono, Sigit Tri; Ardhyananta, Hosta; Rasyida, Amaliya

    2018-04-01

    Base on Sidoarjo's goverment data, there was more than 4000 metric ton perday of waste that has been accumulated during 2016. More than 10 percent from overall waste is plastics. In accordance with the Indonesia government regulation, "Indonesia clean from waste" by 2020 through 3R (Reduce, Reuse and Recycle) program, we have been focusing research on how to reduce the accumulation of the plastics waste in Sidoarjo by processing it become a new product. In this research, we have made the plastic waste of PET bottle as additional fillers or agregates of composite material for construction application as a paving block. The composition of PET plastic used as fillers is vary from 0, 10, 20, 30, 40 and 50% from total volume of agregates. The ratio of cement binder to sands agregate is 1:3. The specimens were characterized its mechanical and physical properties by using flexural testing, compressive testing, density and water absorbance measurement. The results show that the mechanical (flexural and compressive) properties of composite materials is increased significantly by increasing PET fillers up to 20%, however it was decreased when PET content more than 20%. But, both the density and water absobance of specimens are decreased by increasing of PET fillers.

  2. Eco-friendly Fibre from Recycled Polypropylene of Bottle Cap Waste and Lignin

    NASA Astrophysics Data System (ADS)

    Soekoco, A. S.; Basuki, A.; Mardiyati

    2016-01-01

    Ecofriendly fibre is one of potential alternatives to fulfill the rising demand in textile material supply which is limited due to the decreasing reserve of oil. Large amount of polypropylene waste from bottle cap and lignin as a byproduct from pulp industry are potential solutions. Grinded polypropylene bottle cap was blended with lignin powder in concentration of 5 wt. % processed by melt spinning at 170° C temperature. The fibres produced have an average diameter 170 and 250 micrometres. In view of the mechanical properties. the tensile strength is 11.9 MPa for fibre with 170 micrometres diameter and 14.7 MPa for fibre with 250 micrometres diameter. Fibre surface morphology was further studied using micron microscope. and the result shows black flocks spread in the fibre. indicating that the lignin does not blend evenly.

  3. Physical and mechanical properties of mortars containing PET and PC waste aggregates.

    PubMed

    Hannawi, Kinda; Kamali-Bernard, Siham; Prince, William

    2010-11-01

    Non-biodegradable plastic aggregates made of polycarbonate (PC) and polyethylene terephthalate (PET) waste are used as partial replacement of natural aggregates in mortar. Various volume fractions of sand 3%, 10%, 20% and 50% are replaced by the same volume of plastic. This paper investigates the physical and mechanical properties of the obtained composites. The main results of this study show the feasibility of the reuse of PC and PET waste aggregates materials as partial volume substitutes for natural aggregates in cementitious materials. Despite of some drawbacks like a decrease in compressive strength, the use of PC and PET waste aggregates presents various advantages. A reduction of the specific weight of the cementitious materials and a significant improvement of their post-peak flexural behaviour are observed. The calculated flexural toughness factors increase significantly with increasing volume fraction of PET and PC-aggregates. Thus, addition of PC and PET plastic aggregates in cementitious materials seems to give good energy absorbing materials which is very interesting for several civil engineering applications like structures subjected to dynamic or impact efforts. The present study has shown quite encouraging results and opened new way for the recycling of PC waste aggregate in cement and concrete composites. Copyright © 2010 Elsevier Ltd. All rights reserved.

  4. Emissions from small-scale burns of simulated deployed U.S. military waste.

    PubMed

    Woodall, Brian D; Yamamoto, Dirk P; Gullett, Brian K; Touati, Abderrahmane

    2012-10-16

    U.S. military forces have historically relied on open burning as an expedient method of volume reduction and treatment of solid waste during the conflicts in Afghanistan and Iraq. This study is the first effort to characterize a broad range of pollutants and their emission factors during the burning of military waste and the effects that recycling efforts, namely removing plastics, might have on emissions. Piles of simulated military waste were constructed, burned, and emissions sampled at the U.S. Environmental Protection Agency (EPA) Open Burn Testing Facility (OBTF), Research Triangle Park, NC. Three tests contained polyethylene terephthalate (PET #1 or PET) plastic water bottles and four did not. Emission factors for polycyclic aromatic hydrocarbons (PAHs), volatile organic compounds (VOCs), particulate matter (PM(10), PM(2.5)), polychlorinated and polybrominated dioxins/furans (PCDD/F and PBDD/F), and criteria pollutants were determined and are contained within. The average PCDD/F emission factors were 270 ng-toxic equivalency (TEQ) per kg carbon burned (ng-TEQ/kg Cb), ranging from 35 to 780 ng-TEQ/kg Cb. Limited testing suggests that targeted removal of plastic water bottles has no apparent effect on reducing pollutants and may even promote increased emissions.

  5. Influence of content and particle size of waste pet bottles on concrete behavior at different w/c ratios.

    PubMed

    Albano, C; Camacho, N; Hernández, M; Matheus, A; Gutiérrez, A

    2009-10-01

    The goal of this work was to study the mechanical behavior of concrete with recycled Polyethylene Therephtalate (PET), varying the water/cement ratio (0.50 and 0.60), PET content (10 and 20 vol%) and the particle size. Also, the influence of the thermal degradation of PET in the concrete was studied, when the blends were exposed to different temperatures (200, 400, 600 degrees C). Results indicate that PET-filled concrete, when volume proportion and particle size of PET increased, showed a decrease in compressive strength, splitting tensile strength, modulus of elasticity and ultrasonic pulse velocity; however, the water absorption increased. On the other hand, the flexural strength of concrete-PET when exposed to a heat source was strongly dependent on the temperature, water/cement ratio, as well as on the PET content and particle size. Moreover, the activation energy was affected by the temperature, PET particles location on the slabs and water/cement ratio.

  6. Property of filler-loaded magnetic ferrite from plastic waste bottle used to treat municipal domestic sewage.

    PubMed

    Zhao, Ru-Jin; Gong, Li-Ying; Zhu, Hai-Dong; Liu, Qiao; Xu, Li-Xia; Lu, Lu; Yang, Qi-Zhi

    2018-06-01

    The present work investigates the properties of self-made magnetic filler from plastic waste bottle and explores a new technology approach of waste plastic resource utilization. The magnetic filler was prepared by air plasma modification and loading magnetic ferrite on the plastic strip from waste plastic bottle. The surface properties of magnetic filler were characterized by Atomic Force Microscope (AFM), contact angle system and Fourier Transform Infrared (FTIR). AFM images of original and modified plastic strip showed that low-temperature plasma treatment markedly increased the surface roughness of plastic strip. The mean roughness (Ra) of plastic strip rose from 1.116 to 5.024 nm. FTIR spectra indicated that a lot of polar oxygenic groups were introduced onto the surface of plastic by plasma modification. Modification by low-temperature plasma increased the hydrophilicity of plastic strip surface. When treatment time is 40 s, water contact angle of plastic strip surface reduced from 78.2° of original plastic strip to 25.3°. When used in bioreactor, magnetic filler had very favorable microenvironment for microorganism growth. Magnetic filler was more efficient for removing chemical oxygen demand (COD) and [Formula: see text] in sewage than nonmagnetic filler. The resource utilization of plastic wastes will become reality if the magnetic filler is applied widely.

  7. The Utilisation of Shredded PET as Aggregate Replacement for Interlocking Concrete Block

    NASA Astrophysics Data System (ADS)

    Mokhtar, M.; Kaamin, M.; Sahat, S.; Hamid, N. B.

    2018-03-01

    The consumption of plastic has grown substantially all over the world in recent years and this has created huge quantities of plastic-based waste. Plastic waste is now a serious environmental threat to the modern way of living, although steps were taken to reduce its consumption. This creates substantial garbage every day, which is much unhealthy. Plastic bottles such as Polyethylene terephthalate (PET) was use as the partially component in this making of interlocking blocks concrete. This project investigates the strength and workability of the interlocking block concrete by replacing course aggregate with % PET. The suitability of recycled plastics (PET) as course aggregate in interlocking block concrete and its advantages are discussed here. Moreover, there were more benefits when using interlocking block than using conventional block such as it easy for construction because they are aligning, easy to place, high speed stacking and they offer more resistance to shear and buildings would be even stronger. Based on the test perform, the failure parameter were discussed .From the compressive strength test result, it shows that the strength of concrete block decreased with increased of PET used. From the results, it shows that higher compressive strength was found with 5% natural course aggregate replaced with PET compared to other percentages.

  8. The upcycling of post-industrial PP/PET waste streams through in-situ microfibrillar preparation

    NASA Astrophysics Data System (ADS)

    Delva, Laurens; Ragaert, Kim; Cardon, Ludwig

    2015-12-01

    Post-industrial plastic waste streams can be re-used as secondary material streams for polymer processing by extrusion or injection moulding. One of the major commercially available waste stream contains polypropylene (PP) contaminated with polyesters (mostly polyethylene tereftalate - PET). An important practical hurdle for the direct implementation of this waste stream is the immiscibility of PP and PET in the melt, which leads to segregation within the polymer structure and adversely affects the reproducibility and mechanical properties of the manufactured parts. It has been indicated in literature that the creation of PET microfibrils in the PP matrix could undo these drawbacks and upcycle the PP/PET combination. Within the current research, a commercially available virgin PP/PET was evaluated for the microfibrillar preparation. The mechanical (tensile and impact) properties, thermal properties and morphology of the composites were characterized at different stages of the microfibrillar preparation.

  9. Assessing human exposure to phthalic acid and phthalate esters from mineral water stored in polyethylene terephthalate and glass bottles.

    PubMed

    Montuori, P; Jover, E; Morgantini, M; Bayona, J M; Triassi, M

    2008-04-01

    Phthalic acid and phthalate esters are of growing interest due to their significant usage and potential toxicity. Polyethylene terephthalate (PET) and glass are both widely used materials for bottled drinking water. In this study, phthalic acid (PhA), bis(2-ethylhexyl) phthalate (DEHP), dimethyl phthalate (DMP), diethyl phthalate (DEP), diisobutyl phthalate (DiisoBP) and dibutyl phthalate (DBP) were analysed in a large number of Italian bottled water samples. These samples showed different concentrations of phthalates are nearly 20 times higher in samples bottled in PET than those from glass bottles with total levels of phthalates of 3.52 and 0.19 microg l(-1), respectively. However, the observed levels do not represent a significant exposure pathway when considering the US Environmental Protection Agency (USEPA) reference dose (an estimate of a daily oral exposure to the human population, including sensitive subgroups, that is likely to be without an appreciable risk of deleterious effects during a lifetime). In addition, no significant correlation was found between the phthalate concentrations and the physicochemical properties of the different water samples, apart from the still/sparkling water parameter for the PET samples. In this instance, slightly higher concentrations were observed for the PET bottled still water samples than for the sparkling water samples, although no explanation has been found yet.

  10. Thermal properties of Poly(ethylene terephthalate) recovered from municipal solid waste by steam autoclaving

    USDA-ARS?s Scientific Manuscript database

    The goal of this study was to evaluate the effects of steam autoclaving on the properties of PET, data which could ultimately be applied to determine the most likely end use of this potentially huge waste stream. Through the course of the study it was determined that stretch blow molding in bottle ...

  11. Assessment of metal contaminations leaching out from recycling plastic bottles upon treatments.

    PubMed

    Cheng, Xiaoliang; Shi, Honglan; Adams, Craig D; Ma, Yinfa

    2010-08-01

    Heavy metal contaminants in environment, especially in drinking water, are always of great concern due to their health impact. Due to the use of heavy metals as catalysts during plastic syntheses, particularly antimony, human exposure to metal release from plastic bottles has been a serious concern in recent years. The aim and scope of this study were to assess metal contaminations leaching out from a series of recycling plastic bottles upon treatments. In this study, leaching concentrations of 16 metal elements were determined in 21 different types of plastic bottles from five commercial brands, which were made of recycling materials ranging from no. 1 to no. 7. Several sets of experiments were conducted to study the factors that could potentially affect the metal elements leaching from plastic bottles, which include cooling with frozen water, heating with boiling water, microwave, incubating with low-pH water, outdoor sunlight irradiation, and in-car storage. Heating and microwave can lead to a noticeable increase of antimony leaching relative to the controls in bottle samples A to G, and some even reached to a higher level than the maximum contamination level (MCL) of the US Environmental Protection Agency (USEPA) regulations. Incubation with low-pH water, outdoor sunlight irradiation, and in-car storage had no significant effect on antimony leaching relative to controls in bottle samples A to G, and the levels of antimony leaching detected were below 6 ppb which is the MCL of USEPA regulations. Cooling had almost no effect on antimony leaching based on our results. For the other interested 15 metal elements (Al, V, Cr, Mn, Co, Ni, Cu, As, Se, Mo, Ag, Cd, Ba, Tl, Pb), no significant leaching was detected or the level was far below the MCL of USEPA regulations in all bottle samples in this study. In addition, washing procedure did contribute to the antimony leaching concentration for polyethylene terephthalate (PET) bottles. The difference of antimony leaching

  12. Endocrine disruptors in bottled mineral water: total estrogenic burden and migration from plastic bottles.

    PubMed

    Wagner, Martin; Oehlmann, Jörg

    2009-05-01

    Food consumption is an important route of human exposure to endocrine-disrupting chemicals. So far, this has been demonstrated by exposure modeling or analytical identification of single substances in foodstuff (e.g., phthalates) and human body fluids (e.g., urine and blood). Since the research in this field is focused on few chemicals (and thus missing mixture effects), the overall contamination of edibles with xenohormones is largely unknown. The aim of this study was to assess the integrated estrogenic burden of bottled mineral water as model foodstuff and to characterize the potential sources of the estrogenic contamination. In the present study, we analyzed commercially available mineral water in an in vitro system with the human estrogen receptor alpha and detected estrogenic contamination in 60% of all samples with a maximum activity equivalent to 75.2 ng/l of the natural sex hormone 17beta-estradiol. Furthermore, breeding of the molluskan model Potamopyrgus antipodarum in water bottles made of glass and plastic [polyethylene terephthalate (PET)] resulted in an increased reproductive output of snails cultured in PET bottles. This provides first evidence that substances leaching from plastic food packaging materials act as functional estrogens in vivo. Our results demonstrate a widespread contamination of mineral water with xenoestrogens that partly originates from compounds leaching from the plastic packaging material. These substances possess potent estrogenic activity in vivo in a molluskan sentinel. Overall, the results indicate that a broader range of foodstuff may be contaminated with endocrine disruptors when packed in plastics.

  13. Recycled PET Nanofibers for Water Filtration Applications

    PubMed Central

    Zander, Nicole E.; Gillan, Margaret; Sweetser, Daniel

    2016-01-01

    Water shortage is an immediate and serious threat to our world population. Inexpensive and scalable methods to clean freshwater and wastewater are in high demand. Nanofiber filtration membranes represent a next generation nonwoven filter media due to their unique properties. Polyethlyene terephthalate (PET) is often used in the packaging of water and other commonly used materials, leading to a large amount of plastic waste often with limited incentive for recycling (few value-added uses). Here, we present work in the generation of nanofiber liquid filtration membranes from PET plastic bottles and demonstrate their use in microfiltration. PET nanofiber membranes were formed via solution electrospinning with fiber diameters as low as ca. 100 nm. Filtration efficiency was tested with latex beads with sizes ranging from 30 to 2000 nm. Greater than 99% of the beads as small as 500 nm were removed using gravity filtration. To reduce biofouling, the mats were functionalized with quaternary ammonium and biguanide biocides. The biguanide functionalized mats achieved 6 log reduction for both gram negative and gram positive bacteria. PMID:28773380

  14. Waste product profile: Polyethylene terephthalate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, C.

    1996-02-01

    Polyethylene terephthalate (PET) is a plastic resin used primarily to make bottles. Soft drinks are the primary product packaged in PET. Salad dressing, peanut butter, and other household and consumer products also use PET bottles. PET is also used for film, sheeting for cups and food trays, ovenable trays, and other uses. PET is a relatively new packaging resin, first commercialized in the early `70s. Because it is an ``engineered`` resin, it is more expensive than commodity resins such as high-density polyethylene (HDPE). The primary market for recycled PET is the fiber industry, which uses PET for carpet fiber, sweatersmore » and other clothing, and for other uses. Recycled PET can also be used for food and beverage containers. Export markets, particularly Asian countries, are becoming increasingly important.« less

  15. Diffusion behaviour of the acetaldehyde scavenger 2-aminobenzamide in polyethylene terephthalate for beverage bottles

    PubMed Central

    Franz, Roland; Gmeiner, Margit; Gruner, Anita; Kemmer, Diana; Welle, Frank

    2016-01-01

    ABSTRACT Polyethylene terephthalate (PET) bottles are widely used as packaging material for natural mineral water. However, trace levels of acetaldehyde can migrate into natural mineral water during the shelf life and might influence the taste of the PET bottled water. 2-Aminobenzamide is widely used during PET bottle production as a scavenging agent for acetaldehyde. The aim of this study was the determination of the migration kinetics of 2-aminobenzamide into natural mineral water as well as into 20% ethanol. From the migration kinetics, the diffusion coefficients of 2-aminobenzamide in PET at 23 and 40°C were determined to be 4.2 × 10− 16 and 4.2 × 10− 15 cm2 s–1, respectively. The diffusion coefficient for 20% ethanol at 40°C was determined to be 7.7 × 10− 15 cm2 s–1, which indicates that 20% ethanol is causing swelling of the PET polymer. From a comparison of migration values between 23 and 40°C, acceleration factors of 9.7 when using water as contact medium and 18.1 for 20% ethanol as simulant can be derived for definition of appropriate accelerated test conditions at 40°C. The European Union regulatory acceleration test based on 80 kJ mol–1 as conservative activation energy overestimates the experimentally determined acceleration rates by a factor of 1.6 and 3.1, respectively. PMID:26666986

  16. Robust identification of polyethylene terephthalate (PET) plastics through Bayesian decision.

    PubMed

    Zulkifley, Mohd Asyraf; Mustafa, Mohd Marzuki; Hussain, Aini; Mustapha, Aouache; Ramli, Suzaimah

    2014-01-01

    Recycling is one of the most efficient methods for environmental friendly waste management. Among municipal wastes, plastics are the most common material that can be easily recycled and polyethylene terephthalate (PET) is one of its major types. PET material is used in consumer goods packaging such as drinking bottles, toiletry containers, food packaging and many more. Usually, a recycling process is tailored to a specific material for optimal purification and decontamination to obtain high grade recyclable material. The quantity and quality of the sorting process are limited by the capacity of human workers that suffer from fatigue and boredom. Several automated sorting systems have been proposed in the literature that include using chemical, proximity and vision sensors. The main advantages of vision based sensors are its environmentally friendly approach, non-intrusive detection and capability of high throughput. However, the existing methods rely heavily on deterministic approaches that make them less accurate as the variations in PET plastic waste appearance are too high. We proposed a probabilistic approach of modeling the PET material by analyzing the reflection region and its surrounding. Three parameters are modeled by Gaussian and exponential distributions: color, size and distance of the reflection region. The final classification is made through a supervised training method of likelihood ratio test. The main novelty of the proposed method is the probabilistic approach in integrating various PET material signatures that are contaminated by stains under constant lighting changes. The system is evaluated by using four performance metrics: precision, recall, accuracy and error. Our system performed the best in all evaluation metrics compared to the benchmark methods. The system can be further improved by fusing all neighborhood information in decision making and by implementing the system in a graphics processing unit for faster processing speed.

  17. Robust Identification of Polyethylene Terephthalate (PET) Plastics through Bayesian Decision

    PubMed Central

    Zulkifley, Mohd Asyraf; Mustafa, Mohd Marzuki; Hussain, Aini; Mustapha, Aouache; Ramli, Suzaimah

    2014-01-01

    Recycling is one of the most efficient methods for environmental friendly waste management. Among municipal wastes, plastics are the most common material that can be easily recycled and polyethylene terephthalate (PET) is one of its major types. PET material is used in consumer goods packaging such as drinking bottles, toiletry containers, food packaging and many more. Usually, a recycling process is tailored to a specific material for optimal purification and decontamination to obtain high grade recyclable material. The quantity and quality of the sorting process are limited by the capacity of human workers that suffer from fatigue and boredom. Several automated sorting systems have been proposed in the literature that include using chemical, proximity and vision sensors. The main advantages of vision based sensors are its environmentally friendly approach, non-intrusive detection and capability of high throughput. However, the existing methods rely heavily on deterministic approaches that make them less accurate as the variations in PET plastic waste appearance are too high. We proposed a probabilistic approach of modeling the PET material by analyzing the reflection region and its surrounding. Three parameters are modeled by Gaussian and exponential distributions: color, size and distance of the reflection region. The final classification is made through a supervised training method of likelihood ratio test. The main novelty of the proposed method is the probabilistic approach in integrating various PET material signatures that are contaminated by stains under constant lighting changes. The system is evaluated by using four performance metrics: precision, recall, accuracy and error. Our system performed the best in all evaluation metrics compared to the benchmark methods. The system can be further improved by fusing all neighborhood information in decision making and by implementing the system in a graphics processing unit for faster processing speed. PMID

  18. Calcite precipitates in Slovenian bottled waters.

    PubMed

    Stanič, Tamara Ferjan; Miler, Miloš; Brenčič, Mihael; Gosar, Mateja

    2017-06-01

    Storage of bottled waters in varying ambient conditions affects its characteristics. Different storage conditions cause changes in the initial chemical composition of bottled water which lead to the occurrence of precipitates with various morphologies. In order to assess the relationship between water composition, storage conditions and precipitate morphology, a study of four brands of Slovenian bottled water stored in PET bottles was carried out. Chemical analyses of the main ions and measurements of the physical properties of water samples were performed before and after storage of water samples at different ambient conditions. SEM/EDS analysis of precipitates was performed after elapsed storage time. The results show that the presence of Mg 2+ , SO 4 2- , SiO 2 , Al, Mn and other impurities such as K + , Na + , Ba and Sr in the water controlled precipitate morphology by inhibiting crystal growth and leading to elongated rhombohedral calcite crystal forms which exhibit furrowed surfaces and calcite rosettes. Different storage conditions, however, affected the number of crystallization nuclei and size of calcite crystals. Hollow calcite spheres composed of cleavage rhombohedrons formed in the water with variable storage conditions by a combination of evaporation and precipitation of water droplets during high temperatures or by the bubble templating method.

  19. FE-Analysis of Stretch-Blow Moulded Bottles Using an Integrative Process Simulation

    NASA Astrophysics Data System (ADS)

    Hopmann, C.; Michaeli, W.; Rasche, S.

    2011-05-01

    The two-stage stretch-blow moulding process has been established for the large scale production of high quality PET containers with excellent mechanical and optical properties. The total production costs of a bottle are significantly caused by the material costs. Due to this dominant share of the bottle material, the PET industry is interested in reducing the total production costs by an optimised material efficiency. However, a reduced material inventory means decreasing wall thicknesses and therewith a reduction of the bottle properties (e.g. mechanical properties, barrier properties). Therefore, there is often a trade-off between a minimal bottle weight and adequate properties of the bottle. In order to achieve the objectives Computer Aided Engineering (CAE) techniques can assist the designer of new stretch-blow moulded containers. Hence, tools such as the process simulation and the structural analysis have become important in the blow moulding sector. The Institute of Plastics Processing (IKV) at RWTH Aachen University, Germany, has developed an integrative three-dimensional process simulation which models the complete path of a preform through a stretch-blow moulding machine. At first, the reheating of the preform is calculated by a thermal simulation. Afterwards, the inflation of the preform to a bottle is calculated by finite element analysis (FEA). The results of this step are e.g. the local wall thickness distribution and the local biaxial stretch ratios. Not only the material distribution but also the material properties that result from the deformation history of the polymer have significant influence on the bottle properties. Therefore, a correlation between the material properties and stretch ratios is considered in an integrative simulation approach developed at IKV. The results of the process simulation (wall thickness, stretch ratios) are transferred to a further simulation program and mapped on the bottles FE mesh. This approach allows a local

  20. Study on the leaching of phthalates from polyethylene terephthalate bottles into mineral water.

    PubMed

    Keresztes, Szilvia; Tatár, Enikő; Czégény, Zsuzsanna; Záray, Gyula; Mihucz, Victor G

    2013-08-01

    Carbonated and non-carbonated mineral water samples bottled in 0.5-L, 1.5-L and 2.0-L polyethylene terephthalate (PET) containers belonging to three different water brands commercialized in Hungary were studied in order to determine their phthalate content by gas chromatography-mass spectrometry. Among the six investigated phthalates, diisobutyl phthalate, di-n-butyl-phthalate, benzyl-butyl phthalate and di(2-ethyl-hexyl) phthalate (DEHP) were determined in non-carbonated samples as follows: <3.0 ng L(-1)-0.2 μg L(-1), <6.6 ng L(-1)-0.8 μg L(-1), <6.0 ng L(-1)-0.1 μg L(-1) and <16.0 ng L(-1)-1.7 μg L(-1), respectively. Any of the above-mentioned phthalate esters could be detected in carbonated mineral water samples. DEHP was the most abundant phthalate in the investigated samples. It could be detected after 44 days of storage at 22 °C and its leaching was the most pronounced when samples were stored over 1200 days. Mineral water purchased in PET bottles of 0.5L had the highest phthalate concentrations compared to those obtained for waters of the identical brand bottled in 1.5-L or 2.0-L PET containers due to the higher surface/volume ratio. No clear trend could be established for phthalate leaching when water samples were kept at higher temperatures (max. 60 °C) showing improper storage conditions. Phthalate determination by pyrolysis-gas chromatography/mass spectrometric measurements in the plastic material as well as in the aqueous phase proved the importance of the quality of PET raw material used for the production of the pre-form (virgin vs. polymer containing recycled PET). Copyright © 2013 Elsevier B.V. All rights reserved.

  1. Combating oil spill problem using plastic waste.

    PubMed

    Saleem, Junaid; Ning, Chao; Barford, John; McKay, Gordon

    2015-10-01

    Thermoplastic polymers (such as polypropylene, polyethylene, polyethylene terephthalate (PET) and high density polyethylene (HDPE)) constitute 5-15% of municipal solid waste produced across the world. A huge quantity of plastic waste is disposed of each year and is mostly either discarded in landfills or incinerated. On the other hand, the usage of synthetic polymers as oil sorbents, in particular, polyolefins, including polypropylene (PP), and polyethylene (PE) are the most commonly used oil sorbent materials mainly due to their low cost. However, they possess relatively low oil absorption capacities. In this work, we provide an innovative way to produce a value-added product such as oil-sorbent film with high practical oil uptake values in terms of g/g from waste HDPE bottles for rapid oil spill remedy. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Utilization of polyethylene terephthalate (PET) in bituminous mixture for improved performance of roads

    NASA Astrophysics Data System (ADS)

    Ahmad, A. F.; Razali, A. R.; Razelan, I. S. M.; Jalil, S. S. A.; Noh, M. S. M.; Idris, A. A.

    2017-05-01

    Plastic bottle for recycling can be found from the household waste stream, and most of them are made from Polyethylene Terephthalate. In this research, PET is utilized to explore the potential prospects to upgrade asphalt mixture properties. The objectives include deciding the best measure of PET to be used. For experimental, Marshall mix design was utilized to determine the ideal bitumen binder content and to test the modified mixture properties. The samples were created per the requirement for aggregate course wearing (ACW14) using the Standard Specification of Road Work (SSRW) in Malaysia. 20 samples were utilized to determine the binder content, and 30 samples were used to research the impact of modifying asphalt mixtures. 2%, 5%, 10%, 15% and 20% of PET by weight of the optimum binder content (4.8%) were tested. Optimum PET content is 10%, and the result shows a good stability with 16.824kN, 2.32g/cm3 bulk density, void filled with bitumen (VFB) with 71.35%, flow with 3.2248mm, air void (AV) with 4.53%, and void of mineral aggregate (VMA) with 15.15%. The outcomes showed that PET modifier gives better engineering properties. Therefore, 10% of PET by the weight of binder content was suggested as the best amount of the modifier.

  3. The Effect of Adding PET (Polyethylen Terephthalate) Plastic Waste on SCC (Self-Compacting Concrete) to Fresh Concrete Behavior and Mechanical Characteristics

    NASA Astrophysics Data System (ADS)

    Aswatama W, K.; Suyoso, H.; Meyfa U, N.; Tedy, P.

    2018-01-01

    To study the effect PET waste plastics on SCC then PET plastic waste content for SCC is made into 2.5%; 5%; 7.5%; and 10%. As reference concrete is made SCC with 0% PET level. The results on all fresh concrete test items indicate that for all PET waste levels made are meeting the criteria as SCC. The effect of adding PET to fresh concrete behavior on all test items shows that the filling ability and passing ability of concrete work increases with increasing of PET. However, the increase in PET will decrease its mechanical properties. The result of heat test shows that the mechanical properties of concrete (compressive strength, splitting, and elastic modulus) after heating at 250°C temperature has not changed, while at 600°C has significant capacity decline. To clarify the differences between SCC before and after heating, microstructure analysis was done in the form of photo magnification of specimen using SEM (Scanning Electron Microscope).

  4. Photophysical and photochemical effects of UV and VUV photo-oxidation and photolysis on PET and PEN

    NASA Astrophysics Data System (ADS)

    Morgan, Andrew

    Polyethylene Terephthalate (PET) is a widely used polymer in the bottling, packaging, and clothing industry. In recent years an increasing global demand for PET has taken place due to the Solar Disinfection (SODIS) process. SODIS is a method of sterilizing fresh water into drinkable water. The PET bottles are used in the process to contain the water during solar irradiation due to its highly transparent optical property. Alongside PET, polyethylene 2,6-napthalate (PEN) is used in bottling and flexible electronic applications. The surface of PEN would need to be modified to control the hydrophilicity and the interaction it exudes as a substrate. The UV light absorption properties of PET and PEN are of great importance for many applications, and thus needs to be studied along with its photochemical resistance. The optical and chemical nature of PET was studied as it was treated by UV photo-oxidation, photo-ozonation, and photolysis under atmospheric pressure. Another investigation was also used to study PEN and PET as they are treated by vacuum UV (VUV) photo-oxidation, VUV photolysis, and remote oxygen reactions. The extent of the photoreactions' effect into the depth of the polymers is examined as treatment conditions are changed. The different experimental methods established the rate of several competing photoreactions on PET and PEN during irradiance, and their effect on the optical quality of the polymers.

  5. Concentrations of selected trace elements in mineral and spring bottled waters on the Serbian market.

    PubMed

    Ristić, M; Popović, I; Pocajt, V; Antanasijević, D; Perić-Grujić, A

    2011-01-01

    Eight selected trace elements, which are generally included in regulations, were analyzed in 23 types of bottled waters. Ten mineral and seven spring bottled waters were from the Serbian market and six mineral bottled waters were obtained in different EU countries. For the purpose of comparison, selected tap waters were also analyzed. Inductively coupled plasma mass spectrometry (ICP-MS) was used for the analysis of trace elements (arsenic, cadmium, copper, manganese, nickel, lead and antimony). Results were compared with the Serbian regulations for bottled water, EU regulations and guideline values set by the World Health Organization for drinking water. With few exceptions, the trace element levels of most bottled waters were below the guideline values. However, a higher content of antimony was observed in waters from polyethylene terephthalate (PET) containers, indicating a potential leaching of this element from the plastic packaging.

  6. Sustainable Engineering and Improved Recycling of PET for High-Value Applications: Transforming Linear PET to Lightly Branched PET with a Novel, Scalable Process

    NASA Astrophysics Data System (ADS)

    Pierre, Cynthia; Torkelson, John

    2009-03-01

    A major challenge for the most effective recycling of poly(ethylene terephthalate) concerns the fact that initial melt processing of PET into a product leads to substantial degradation of molecular weight. Thus, recycled PET has insufficient melt viscosity for reuse in high-value applications such as melt-blowing of PET bottles. Academic and industrial research has tried to remedy this situation by synthesis and use of ``chain extenders'' that can lead to branched PET (with higher melt viscosity than the linear recycled PET) via condensation reactions with functional groups on the PET. Here we show that simple processing of PET via solid-state shear pulverization (SSSP) leads to enhanced PET melt viscosity without need for chemical additives. We hypothesize that this branching results from low levels of chain scission accompanying SSSP, leading to formation of polymeric radicals that participate in chain transfer and combination reactions with other PET chains and thereby to in situ branch formation. The pulverized PET exhibits vastly enhanced crystallization kinetics, eliminating the need to employ cold crystallization to achieve maximum PET crystallinity. Results of SSSP processing of PET will be compared to results obtained with poly(butylene terephthalate).

  7. A new classification scheme of plastic wastes based upon recycling labels

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Özkan, Kemal, E-mail: kozkan@ogu.edu.tr; Ergin, Semih, E-mail: sergin@ogu.edu.tr; Işık, Şahin, E-mail: sahini@ogu.edu.tr

    Highlights: • PET, HPDE or PP types of plastics are considered. • An automated classification of plastic bottles based on the feature extraction and classification methods is performed. • The decision mechanism consists of PCA, Kernel PCA, FLDA, SVD and Laplacian Eigenmaps methods. • SVM is selected to achieve the classification task and majority voting technique is used. - Abstract: Since recycling of materials is widely assumed to be environmentally and economically beneficial, reliable sorting and processing of waste packaging materials such as plastics is very important for recycling with high efficiency. An automated system that can quickly categorize thesemore » materials is certainly needed for obtaining maximum classification while maintaining high throughput. In this paper, first of all, the photographs of the plastic bottles have been taken and several preprocessing steps were carried out. The first preprocessing step is to extract the plastic area of a bottle from the background. Then, the morphological image operations are implemented. These operations are edge detection, noise removal, hole removing, image enhancement, and image segmentation. These morphological operations can be generally defined in terms of the combinations of erosion and dilation. The effect of bottle color as well as label are eliminated using these operations. Secondly, the pixel-wise intensity values of the plastic bottle images have been used together with the most popular subspace and statistical feature extraction methods to construct the feature vectors in this study. Only three types of plastics are considered due to higher existence ratio of them than the other plastic types in the world. The decision mechanism consists of five different feature extraction methods including as Principal Component Analysis (PCA), Kernel PCA (KPCA), Fisher’s Linear Discriminant Analysis (FLDA), Singular Value Decomposition (SVD) and Laplacian Eigenmaps (LEMAP) and uses a simple

  8. Migration measurement and modelling from poly(ethylene terephthalate) (PET) into soft drinks and fruit juices in comparison with food simulants.

    PubMed

    Franz, R; Welle, F

    2008-08-01

    Poly(ethylene terephthalate) (PET) bottles are widely used for beverages. Knowledge about the migration of organic compounds from the PET bottle wall into contact media is of interest especially when post-consumer recyclates are introduced into new PET bottles. Using migration theory, the migration of a compound can be calculated if the concentration in the bottle wall is known. On the other hand, for any given specific migration limit or maximum target concentration for organic chemical compounds in the bottled foodstuffs, the maximum allowable concentrations in the polymer CP,0 can be calculated. Since a food simulant cannot exactly simulate the real migration into the foodstuff or beverages, a worse-case simulation behaviour is the intention. However, if the migration calculation should not be too overestimative, the polymer-specific kinetic parameter for migration modelling, the so-called AP value, should be established appropriately. One objective of the study was the kinetic determination of the specific migration behaviour of low molecular weight compounds such as solvents with relatively high diffusion rates and, therefore, with high migration potential from the PET bottle wall into food simulants in comparison with real beverages. For this purpose, model contaminants were introduced into the bottle wall during pre-form production. The volatile compounds toluene and chlorobenzene were established at concentrations from about 20-30 mg kg(-1) to 300-350 mg kg(-1). Phenyl cyclohexane was present at concentrations of 35, 262 and 782 mg kg(-1), respectively. The low volatile compounds benzophenone and methyl stearate have bottle wall concentrations of about 100 mg kg(-1) in the low spiking level up to about 1000 mg kg(-1) in the highly spiked test bottle. From these experimental data, the polymer specific parameters (AP values) from mathematical migration modelling were derived. The experimental determined diffusing coefficients were determined, calculated and

  9. A new classification scheme of plastic wastes based upon recycling labels.

    PubMed

    Özkan, Kemal; Ergin, Semih; Işık, Şahin; Işıklı, Idil

    2015-01-01

    Since recycling of materials is widely assumed to be environmentally and economically beneficial, reliable sorting and processing of waste packaging materials such as plastics is very important for recycling with high efficiency. An automated system that can quickly categorize these materials is certainly needed for obtaining maximum classification while maintaining high throughput. In this paper, first of all, the photographs of the plastic bottles have been taken and several preprocessing steps were carried out. The first preprocessing step is to extract the plastic area of a bottle from the background. Then, the morphological image operations are implemented. These operations are edge detection, noise removal, hole removing, image enhancement, and image segmentation. These morphological operations can be generally defined in terms of the combinations of erosion and dilation. The effect of bottle color as well as label are eliminated using these operations. Secondly, the pixel-wise intensity values of the plastic bottle images have been used together with the most popular subspace and statistical feature extraction methods to construct the feature vectors in this study. Only three types of plastics are considered due to higher existence ratio of them than the other plastic types in the world. The decision mechanism consists of five different feature extraction methods including as Principal Component Analysis (PCA), Kernel PCA (KPCA), Fisher's Linear Discriminant Analysis (FLDA), Singular Value Decomposition (SVD) and Laplacian Eigenmaps (LEMAP) and uses a simple experimental setup with a camera and homogenous backlighting. Due to the giving global solution for a classification problem, Support Vector Machine (SVM) is selected to achieve the classification task and majority voting technique is used as the decision mechanism. This technique equally weights each classification result and assigns the given plastic object to the class that the most classification

  10. 120 MeV Ni Ion beam induced modifications in poly (ethylene terephthalate) used in commercial bottled water

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kumar, Vijay; Sonkawade, R. G.; Ali, Yasir

    2012-06-05

    We report the effects of heavy ion irradiation on the optical, structural, and chemical properties of polyethylene terephthalate (PET) film used in commercial bottled water. PET bottles were exposed with 120 MeV Ni ions at fluences varying from 3 x 10{sup 10} to 3 x 10{sup 12} ion/cm{sup 2}. The modifications so induced were analyzed by using UV-Vis, X-ray diffraction (XRD) and Fourier Transform Infrared (FTIR) spectroscopy. Substantial decrease in optical band gap is observed with the increase in ion fluence. In the FTIR spectra, most of bands are decreased due the degradation of the molecular structure. XRD measurements showmore » the decrease in peak intensity, which reflects the loss of crystallinity after irradiation.« less

  11. Migration of bisphenol A from plastic baby bottles, baby bottle liners and reusable polycarbonate drinking bottles.

    PubMed

    Kubwabo, C; Kosarac, I; Stewart, B; Gauthier, B R; Lalonde, K; Lalonde, P J

    2009-06-01

    Human exposure to bisphenol A (BPA) has recently received special attention. It has been shown that exposure to BPA may occur through the consumption of beverages or foods that have been in contact with polycarbonate (PC) plastic containers or epoxy resins in food packaging. A BPA migration study was conducted using a variety of plastic containers, including polycarbonate baby bottles, non-PC baby bottles, baby bottle liners, and reusable PC drinking bottles. Water was used to simulate migration into aqueous and acidic foods; 10% ethanol solution to simulate migration to low- and high-alcoholic foods; and 50% ethanol solution to simulate migration to fatty foods. By combining solid-phase extraction, BPA derivatization and analysis by GC-EI/MS/MS, a very low detection limit at the ng l(-1) level was obtained. Migration of BPA at 40 degrees C ranged from 0.11 microg l(-1) in water incubated for 8 h to 2.39 microg l(-1) in 50% ethanol incubated for 240 h. Residual BPA leaching from PC bottles increased with temperature and incubation time. In comparison with the migration observed from PC bottles, non-PC baby bottles and baby bottle liners showed only trace levels of BPA. Tests for leachable lead and cadmium were also conducted on glass baby bottles since these represent a potential alternative to plastic bottles. No detectable lead or cadmium was found to leach from the glass. This study indicated that non-PC plastic baby bottles, baby bottle liners and glass baby bottles might be good alternatives for polycarbonate bottles.

  12. Highly flexible binder-free core-shell nanofibrous electrode for lightweight electrochemical energy storage using recycled water bottles

    NASA Astrophysics Data System (ADS)

    Shi, HaoTian H.; Naguib, Hani E.

    2016-08-01

    The creation of a novel flexible nanocomposite fiber with conductive polymer polyaniline (PAni) coating on a polyethylene terephthalate (PET) substrate allowed for increased electrochemical performance while retaining ideal mechanical properties such as very high flexibility. Binder-free PAni-wrapped PET (PAni@PET) fiber with a core-shell structure was successfully fabricated through a novel technique. The PET nanofiber substrate was fabricated through an optimized electrospinning method, while the PAni shell was chemically polymerized onto the surface of the nanofibers. The PET substrate can be made directly from recycled PETE1 grade plastic water bottles. The resulting nanofiber with an average diameter of 121 nm ± 39 nm, with a specific surface area of 83.72 m2 g-1, led to better ionic interactions at the electrode/electrolyte interface. The PAni active layer coating was found to be 69 nm in average thickness. The specific capacitance was found to have increased dramatically from pure PAni with carbon binders. The specific capacitance was found to be 347 F g-1 at a relatively high scan rate of 10 mV s-1. The PAni/PET fiber also experienced very little degradation (4.4%) in capacitance after 1500 galvanostatic charge/discharge cycles at a specific current of 1.2 A g-1. The mesoporous structure of the PAni@PET fibrous mat also allowed for tunable capacitance by controlling the pore sizes. This novel fabrication method offers insights for the utilization of recycled PETE1 based bottles as a high performance, low cost, highly flexible supercapacitor device.

  13. Infections That Pets Carry (For Parents)

    MedlinePlus

    ... urine, and feces. Limit young kids' contact with outdoor pets that hunt and kill for food because ... free of waste. If your pet eliminates waste outdoors, pick up waste regularly and don't allow ...

  14. Finite Element Modeling of Reheat Stretch Blow Molding of PET

    NASA Astrophysics Data System (ADS)

    Krishnan, Dwarak; Dupaix, Rebecca B.

    2004-06-01

    Poly (ethylene terephthalate) or PET is a polymer used as a packaging material for consumer products such as beverages, food or other liquids, and in other applications including drawn fibers and stretched films. Key features that make it widely used are its transparency, dimensional stability, gas impermeability, impact resistance, and high stiffness and strength in certain preferential directions. These commercially useful properties arise from the fact that PET crystallizes upon deformation above the glass transition temperature. Additionally, this strain-induced crystallization causes the deformation behavior of PET to be highly sensitive to processing conditions. It is thus crucial for engineers to be able to predict its performance at various process temperatures, strain rates and strain states so as to optimize the manufacturing process. In addressing these issues; a finite element analysis of the reheat blow molding process with PET has been carried out using ABAQUS. The simulation employed a constitutive model for PET developed by Dupaix and Boyce et al.. The model includes the combined effects of molecular orientation and strain-induced crystallization on strain hardening when the material is deformed above the glass transition temperature. The simulated bottles were also compared with actual blow molded bottles to evaluate the validity of the simulation.

  15. Thuringische builds large PET plant in Germany

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alperowicz, N.

    1993-02-03

    East Germany fibers producer Thuringische Faser AG Schwarza (TFS; Rudolstadt) is entering the polyethylene terephthalate (PET) business. The company, owned by India's Dalmia Group (New Delhi), is building an 80,000-m.t./year PET granulate plant, one of the largest in Europe, for completion at the end of 1995. The product will be used to make PET bottles and film for food packaging. TFS will need to buy 70,000 m.t./year of purified terephthalic acid and 27,000 m.t./year of ethylene glycol to feed the new plant. When acquiring TFS, Dalmia's chairman, Sanjay Dalmia, pledged to invest DM150 million ($95.4 million) in the Germany firmmore » and keep 1,200 of the 3,000 workers. John Brown Deutsche Engineering (Essen) has been awarded a contract covering engineering, know-how, and turnkey supply of the complete plant, and will share of the complete plant, and will share the work with Austrian associate, Voest John Brown Industrieanlagenbau (Linz). The company, which completed against Zimmer (Frankfurt), will use its own technology. TFS, with 1992 sales of DM120 million, has capacities to produce 20,000 m.t/year of viscose staple fiber, 18,000 m.t./year of nylon-6 filament yarn, and 6,300 m.t./year of textile-grade polyester granulate, which will be converted to produce bottle-grade PET.« less

  16. Synthesis of carbon nanostructures from high density polyethylene (HDPE) and polyethylene terephthalate (PET) waste by chemical vapour deposition

    NASA Astrophysics Data System (ADS)

    Hatta, M. N. M.; Hashim, M. S.; Hussin, R.; Aida, S.; Kamdi, Z.; Ainuddin, AR; Yunos, MZ

    2017-10-01

    In this study, carbon nanostructures were synthesized from High Density Polyethylene (HDPE) and Polyethylene terephthalate (PET) waste by single-stage chemical vapour deposition (CVD) method. In CVD, iron was used as catalyst and pyrolitic of carbon source was conducted at temperature 700, 800 and 900°C for 30 minutes. Argon gas was used as carrier gas with flow at 90 sccm. The synthesized carbon nanostructures were characterized by FESEM, EDS and calculation of carbon yield (%). FESEM micrograph shows that the carbon nanostructures were only grown as nanofilament when synthesized from PET waste. The synthesization of carbon nanostructure at 700°C was produced smooth and the smallest diameter nanofilament compared to others. The carbon yield of synthesized carbon nanostructures from PET was lower from HDPE. Furthermore, the carbon yield is recorded to increase with increasing of reaction temperature for all samples. Elemental study by EDS analysis were carried out and the formation of carbon nanostructures was confirmed after CVD process. Utilization of polymer waste to produce carbon nanostructures is beneficial to ensure that the carbon nanotechnology will be sustained in future.

  17. Microbes on a Bottle: Substrate, Season and Geography Influence Community Composition of Microbes Colonizing Marine Plastic Debris.

    PubMed

    Oberbeckmann, Sonja; Osborn, A Mark; Duhaime, Melissa B

    2016-01-01

    Plastic debris pervades in our oceans and freshwater systems and the potential ecosystem-level impacts of this anthropogenic litter require urgent evaluation. Microbes readily colonize aquatic plastic debris and members of these biofilm communities are speculated to include pathogenic, toxic, invasive or plastic degrading-species. The influence of plastic-colonizing microorganisms on the fate of plastic debris is largely unknown, as is the role of plastic in selecting for unique microbial communities. This work aimed to characterize microbial biofilm communities colonizing single-use poly(ethylene terephthalate) (PET) drinking bottles, determine their plastic-specificity in contrast with seawater and glass-colonizing communities, and identify seasonal and geographical influences on the communities. A substrate recruitment experiment was established in which PET bottles were deployed for 5-6 weeks at three stations in the North Sea in three different seasons. The structure and composition of the PET-colonizing bacterial/archaeal and eukaryotic communities varied with season and station. Abundant PET-colonizing taxa belonged to the phylum Bacteroidetes (e.g. Flavobacteriaceae, Cryomorphaceae, Saprospiraceae-all known to degrade complex carbon substrates) and diatoms (e.g. Coscinodiscophytina, Bacillariophytina). The PET-colonizing microbial communities differed significantly from free-living communities, but from particle-associated (>3 μm) communities or those inhabiting glass substrates. These data suggest that microbial community assembly on plastics is driven by conventional marine biofilm processes, with the plastic surface serving as raft for attachment, rather than selecting for recruitment of plastic-specific microbial colonizers. A small proportion of taxa, notably, members of the Cryomorphaceae and Alcanivoraceae, were significantly discriminant of PET but not glass surfaces, conjuring the possibility that these groups may directly interact with the PET

  18. Microbes on a Bottle: Substrate, Season and Geography Influence Community Composition of Microbes Colonizing Marine Plastic Debris

    PubMed Central

    Osborn, A. Mark

    2016-01-01

    Plastic debris pervades in our oceans and freshwater systems and the potential ecosystem-level impacts of this anthropogenic litter require urgent evaluation. Microbes readily colonize aquatic plastic debris and members of these biofilm communities are speculated to include pathogenic, toxic, invasive or plastic degrading-species. The influence of plastic-colonizing microorganisms on the fate of plastic debris is largely unknown, as is the role of plastic in selecting for unique microbial communities. This work aimed to characterize microbial biofilm communities colonizing single-use poly(ethylene terephthalate) (PET) drinking bottles, determine their plastic-specificity in contrast with seawater and glass-colonizing communities, and identify seasonal and geographical influences on the communities. A substrate recruitment experiment was established in which PET bottles were deployed for 5–6 weeks at three stations in the North Sea in three different seasons. The structure and composition of the PET-colonizing bacterial/archaeal and eukaryotic communities varied with season and station. Abundant PET-colonizing taxa belonged to the phylum Bacteroidetes (e.g. Flavobacteriaceae, Cryomorphaceae, Saprospiraceae—all known to degrade complex carbon substrates) and diatoms (e.g. Coscinodiscophytina, Bacillariophytina). The PET-colonizing microbial communities differed significantly from free-living communities, but from particle-associated (>3 μm) communities or those inhabiting glass substrates. These data suggest that microbial community assembly on plastics is driven by conventional marine biofilm processes, with the plastic surface serving as raft for attachment, rather than selecting for recruitment of plastic-specific microbial colonizers. A small proportion of taxa, notably, members of the Cryomorphaceae and Alcanivoraceae, were significantly discriminant of PET but not glass surfaces, conjuring the possibility that these groups may directly interact with the

  19. Taiwan`s experience with municipal waste recycling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, C.H.

    1998-12-31

    Currently, each person on the average produces 1.15 kg of the municipal waste per day and a total of 9 million metric tons were generated annually in Taiwan. The disposal of such a huge amount of waste presents tremendous challenge for the island due to the scarcity of landfills and incineration facilities available locally. EPA of Taiwan, R.O.C. thus takes an active role in promoting waste recycling to reduce the garbage produced in municipalities. In order to efficiently utilize the government`s human and financial resources used in recycling, started from January 31, 1989, EPA has mandated the producer responsibility recyclingmore » program for several designated post-consumer products such as PET, PVC bottles, scrap tires, scrap motor vehicles, etc. Producer responsibility recycling program specifies that the manufacturers, importers and sellers of these designated products have the responsibility to retrieve their products and recycle them properly. Several negative effects have been encountered while the implementation of this producer responsibility recycling program in Taiwan which resulted in a modification of this recycling program recently. This paper presents the encountered experiences on the implementation of municipal waste recycling program in Taiwan.« less

  20. Solar Disinfection of Viruses in Polyethylene Terephthalate Bottles

    PubMed Central

    Carratalà, Anna; Dionisio Calado, Alex; Mattle, Michael J.; Meierhofer, Regula; Luzi, Samuel

    2015-01-01

    Solar disinfection (SODIS) of drinking water in polyethylene terephthalate (PET) bottles is a simple, efficient point-of-use technique for the inactivation of many bacterial pathogens. In contrast, the efficiency of SODIS against viruses is not well known. In this work, we studied the inactivation of bacteriophages (MS2 and ϕX174) and human viruses (echovirus 11 and adenovirus type 2) by SODIS. We conducted experiments in PET bottles exposed to (simulated) sunlight at different temperatures (15, 22, 26, and 40°C) and in water sources of diverse compositions and origins (India and Switzerland). Good inactivation of MS2 (>6-log inactivation after exposure to a total fluence of 1.34 kJ/cm2) was achieved in Swiss tap water at 22°C, while less-efficient inactivation was observed in Indian waters and for echovirus (1.5-log inactivation at the same fluence). The DNA viruses studied, ϕX174 and adenovirus, were resistant to SODIS, and the inactivation observed was equivalent to that occurring in the dark. High temperatures enhanced MS2 inactivation substantially; at 40°C, 3-log inactivation was achieved in Swiss tap water after exposure to a fluence of only 0.18 kJ/cm2. Overall, our findings demonstrate that SODIS may reduce the load of single-stranded RNA (ssRNA) viruses, such as echoviruses, particularly at high temperatures and in photoreactive matrices. In contrast, complementary measures may be needed to ensure efficient inactivation during SODIS of DNA viruses resistant to oxidation. PMID:26497451

  1. Solar Disinfection of Viruses in Polyethylene Terephthalate Bottles.

    PubMed

    Carratalà, Anna; Dionisio Calado, Alex; Mattle, Michael J; Meierhofer, Regula; Luzi, Samuel; Kohn, Tamar

    2016-01-01

    Solar disinfection (SODIS) of drinking water in polyethylene terephthalate (PET) bottles is a simple, efficient point-of-use technique for the inactivation of many bacterial pathogens. In contrast, the efficiency of SODIS against viruses is not well known. In this work, we studied the inactivation of bacteriophages (MS2 and ϕX174) and human viruses (echovirus 11 and adenovirus type 2) by SODIS. We conducted experiments in PET bottles exposed to (simulated) sunlight at different temperatures (15, 22, 26, and 40°C) and in water sources of diverse compositions and origins (India and Switzerland). Good inactivation of MS2 (>6-log inactivation after exposure to a total fluence of 1.34 kJ/cm(2)) was achieved in Swiss tap water at 22°C, while less-efficient inactivation was observed in Indian waters and for echovirus (1.5-log inactivation at the same fluence). The DNA viruses studied, ϕX174 and adenovirus, were resistant to SODIS, and the inactivation observed was equivalent to that occurring in the dark. High temperatures enhanced MS2 inactivation substantially; at 40°C, 3-log inactivation was achieved in Swiss tap water after exposure to a fluence of only 0.18 kJ/cm(2). Overall, our findings demonstrate that SODIS may reduce the load of single-stranded RNA (ssRNA) viruses, such as echoviruses, particularly at high temperatures and in photoreactive matrices. In contrast, complementary measures may be needed to ensure efficient inactivation during SODIS of DNA viruses resistant to oxidation. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  2. Banning the Bottle

    ERIC Educational Resources Information Center

    Palliser, Janna

    2010-01-01

    Bottled water is ubiquitous, taken for granted, and seemingly benign. Americans are consuming bottled water in massive amounts and spending a lot of money: In 2007, Americans spent $11.7 billion on 8.8 billions gallons of bottled water (Gashler 2008). That same year, two million plastic water bottles were used in the United States every five…

  3. An Investigation into the Effects of Temperature and Storage Time on Military Packaged Water in Afghanistan - The Liberation and Migration of Potential Contaminants from Expeditionary Water Packaging System Polyethylene Terephthalate Water Bottles

    DTIC Science & Technology

    2012-03-29

    PET   bottle   degradation   due   to   storage   at   elevated   temperatures.   Results   have   direct... bottle   degradation   of   chemical   and   aesthetic   drinking   water   characteristics   with   extended   storage  at...elevated  temperatures.  To  elucidate  the  impact  of   bottled  water  storage  practices

  4. Influence of Elevated Temperatures on Pet-Concrete Properties

    NASA Astrophysics Data System (ADS)

    Albano, C.; Camacho, N.; Hernández, M.; Matheus, A.; Gutiérrez, A.

    2008-08-01

    Lightweight aggregate is an important material in reducing the unit weight of concrete complying with special concrete structures of large high-rise buildings. Besides, the use of recycled PET bottles as lightweight aggregate in concrete is an effective contribution for environment preservation. So, the objective of the present work was to study experimentally the flexural strength of the PET -concrete blends and the thermal degradation of the PET in the concrete, when the blends with 10 and 20% in volume of PET were exposed to different temperatures (200, 400, 600 °C). The flexural strength of concrete-PET exposed to a heat source is strongly dependent on the temperature, water/cement ratio, as well as the content and particle size of PET. However, the activation energy is affected by the temperature, location of the PET particles on the slabs and the water/cement ratio. Higher water content originates thermal and hydrolytic degradation on the PET, while on the concrete, a higher vapor pressure which causes an increase in crack formation. The values of the activation energy are higher on the center of the slabs than on the surface, since concrete is a poor heat conductor.

  5. The Unintended Consequences of Changes in Beverage Options and the Removal of Bottled Water on a University Campus.

    PubMed

    Berman, Elizabeth R; Johnson, Rachel K

    2015-07-01

    We investigated how the removal of bottled water along with a minimum healthy beverage requirement affected the purchasing behavior, healthiness of beverage choices, and consumption of calories and added sugars of university campus consumers. With shipment data as a proxy, we estimated bottled beverage consumption over 3 consecutive semesters: baseline (spring 2012), when a 30% healthy beverage ratio was enacted (fall 2012), and when bottled water was removed (spring 2013) at the University of Vermont. We assessed changes in number and type of beverages and per capita calories, total sugars, and added sugars shipped. Per capita shipments of bottles, calories, sugars, and added sugars increased significantly when bottled water was removed. Shipments of healthy beverages declined significantly, whereas shipments of less healthy beverages increased significantly. As bottled water sales dropped to zero, sales of sugar-free beverages and sugar-sweetened beverages increased. The bottled water ban did not reduce the number of bottles entering the waste stream from the university campus, the ultimate goal of the ban. With the removal of bottled water, consumers increased their consumption of less healthy bottled beverages.

  6. Evaluating localism in the management of post-consumer plastic bottles in Honolulu, Hawai'i: perspectives from industrial ecology and political ecology.

    PubMed

    Park, Joo Young; Gupta, Clare

    2015-05-01

    Localism or regionalization has become a popular topic in urban design, but recent critics raise the question of whether the local or regional scale is most desirable for industrial ecosystems. As a way to explore the claim that localized metabolism is more sustainable, this study examines the costs and benefits of two differentially scaled strategies for the management of post-consumer polyethylene terephthalate (PET) bottles originating in the city of Honolulu, Hawai'i: local incineration and trans-continental recycling. We first estimate total environmental impacts of two options using life cycle assessment, and then disaggregate them into local versus non-local impacts to examine the spatial distribution of costs and benefits. We further assess the environmental justification for localized waste management in relation to the broader socio-economic motivations that underlie the way that plastics are managed in Honolulu. In doing so we assess the scale at which waste management is optimized from an environmental standpoint as well as the non-environmental considerations such as security and safety that influence the politics of scale involved in urban metabolic design. By illustrating the trade-offs between a local versus global metabolic pathway for plastic waste, the results from our Honolulu case study are globally relevant for communities interested in sustainable urban design and in particular urban waste management. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. Analysis of polyethylene terephthalate PET plastic bottle jointing system using finite element method (FEM)

    NASA Astrophysics Data System (ADS)

    Zaidi, N. A.; Rosli, Muhamad Farizuan; Effendi, M. S. M.; Abdullah, Mohamad Hariri

    2017-09-01

    For almost all injection molding applications of Polyethylene Terephthalate (PET) plastic was analyzed the strength, durability and stiffness of properties by using Finite Element Method (FEM) for jointing system of wood furniture. The FEM was utilized for analyzing the PET jointing system for Oak and Pine as wood based material of furniture. The difference pattern design of PET as wood jointing furniture gives the difference value of strength furniture itself. The results show the wood specimen with grooves and eclipse pattern design PET jointing give lower global estimated error is 28.90%, compare to the rectangular and non-grooves wood specimen of global estimated error is 63.21%.

  8. A pilot study comparing opaque, weighted bottles with conventional, clear bottles for infant feeding

    PubMed Central

    Ventura, Alison K.; Golen, Rebecca Pollack

    2015-01-01

    Compared to breast-fed infants, bottle-fed infants consume greater volumes and gain more weight during infancy. It is hypothesized that the visual and weight cues afforded by bottle-feeding may lead mothers to overfeed in response to the amount of liquid in the bottle. The aim of the present pilot study was to test this hypothesis by comparing mothers’ sensitivity and responsiveness to infant cues and infants’ intakes when mothers use opaque, weighted bottles (that remove visual and weight cues) compared to conventional, clear bottles to feed their infants. We also tested the hypothesis that mothers’ pressuring feeding style would moderate the effect of bottle type on mothers’ sensitivity and responsiveness to infant cues and infant intake. Formula-feeding dyads (N=25) visited our laboratory on two separate days. Mothers fed their infants from a clear bottle one day and an opaque, weighted bottle on the other; bottle-order was counterbalanced across the two days. Both bottles were glass with latex, low-flow nipples; the opaque bottle was fitted with a silicone sleeve containing a 60-g metal plate in its base. Infant intake was assessed by weighing each bottle before and after the feeding. Maternal sensitivity and responsiveness to infant cues was objectively assessed using the Nursing Child Assessment Feeding Scale (NCAFS). Mothers were significantly more responsive to infant cues when they used opaque compared to clear bottles (p=.04). There was also a trend for infants to consume significantly less formula when fed from opaque compared to clear bottles (p = .08). Mothers’ pressuring feeding style moderated the effect of bottle type on maternal responsiveness to infant cues (p = .02) and infant intake (p = .03). Specifically, mothers who reported higher levels of pressuring feeding were significantly more responsive to their infants’ cues (p = .02) and fed their infants significantly less formula when using opaque versus clear bottles (p = .01

  9. Combating oil spill problem using plastic waste

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Saleem, Junaid, E-mail: junaidupm@gmail.com; Ning, Chao; Barford, John

    Highlights: • Up-cycling one type of pollution i.e. plastic waste and successfully using it to combat the other type of pollution i.e. oil spill. • Synthesized oil sorbent that has extremely high oil uptake of 90 g/g after prolonged dripping of 1 h. • Synthesized porous oil sorbent film which not only facilitates in oil sorption but also increases the affinity between sorbent and oil by means of adhesion. - Abstract: Thermoplastic polymers (such as polypropylene, polyethylene, polyethylene terephthalate (PET) and high density polyethylene (HDPE)) constitute 5–15% of municipal solid waste produced across the world. A huge quantity of plasticmore » waste is disposed of each year and is mostly either discarded in landfills or incinerated. On the other hand, the usage of synthetic polymers as oil sorbents, in particular, polyolefins, including polypropylene (PP), and polyethylene (PE) are the most commonly used oil sorbent materials mainly due to their low cost. However, they possess relatively low oil absorption capacities. In this work, we provide an innovative way to produce a value-added product such as oil-sorbent film with high practical oil uptake values in terms of g/g from waste HDPE bottles for rapid oil spill remedy.« less

  10. Properties of concrete modified with waste Low Density Polyethylene and saw dust ash

    NASA Astrophysics Data System (ADS)

    Srimanikandan, P.; Sreenath, S.

    2017-07-01

    The increase in industrialization creates need for disposal of large quantity of by-products. To overcome the difficulty of disposal, these by-products can be used as a replacement for raw material. In this concern, non-conventional industrial wastes such as plastic bags, PET bottles, pulverized waste Low Density Polyethylene (LDPE) and biological waste such as saw-dust ash, coconut coir were used as a replacement in concrete. In this project, saw-dust ash and pulverized waste LDPE were introduced as the partial replacement for cement and fine aggregates respectively. 0%, 5%, 10%, 15% and 20% of sand by volume was replaced with LDPE and 0%, 1%, 3%, 5% and 10% of cement by volume was replaced with saw dust ash. Standard cube, cylinder and prism specimens were cast to assess the compressive strength, split tensile strength and flexural strength of modified concrete after 28 days of curing. Optimum percentage of replacement was found by comparing the test results. The mix with 5% of LDPE and 3% of saw dust ash showed a better result among the other mixes.

  11. The Unintended Consequences of Changes in Beverage Options and the Removal of Bottled Water on a University Campus

    PubMed Central

    Berman, Elizabeth R.

    2015-01-01

    Objectives. We investigated how the removal of bottled water along with a minimum healthy beverage requirement affected the purchasing behavior, healthiness of beverage choices, and consumption of calories and added sugars of university campus consumers. Methods. With shipment data as a proxy, we estimated bottled beverage consumption over 3 consecutive semesters: baseline (spring 2012), when a 30% healthy beverage ratio was enacted (fall 2012), and when bottled water was removed (spring 2013) at the University of Vermont. We assessed changes in number and type of beverages and per capita calories, total sugars, and added sugars shipped. Results. Per capita shipments of bottles, calories, sugars, and added sugars increased significantly when bottled water was removed. Shipments of healthy beverages declined significantly, whereas shipments of less healthy beverages increased significantly. As bottled water sales dropped to zero, sales of sugar-free beverages and sugar-sweetened beverages increased. Conclusions. The bottled water ban did not reduce the number of bottles entering the waste stream from the university campus, the ultimate goal of the ban. With the removal of bottled water, consumers increased their consumption of less healthy bottled beverages. PMID:25973813

  12. A pilot study comparing opaque, weighted bottles with conventional, clear bottles for infant feeding.

    PubMed

    Ventura, Alison K; Pollack Golen, Rebecca

    2015-02-01

    It is hypothesized that the visual and weight cues afforded by bottle-feeding may lead mothers to overfeed in response to the amount of liquid in the bottle. The aim of the present pilot study was to test this hypothesis by comparing mothers' sensitivity and responsiveness to infant cues and infants' intakes when mothers use opaque, weighted bottles (that remove visual and weight cues) compared to conventional, clear bottles to feed their infants. We also tested the hypothesis that mothers' pressuring feeding style would moderate the effect of bottle type. Formula-feeding dyads (N = 25) visited our laboratory on two separate days. Mothers fed their infants from a clear bottle one day and an opaque, weighted bottle on the other; bottle-order was counterbalanced across the two days. Infant intake was assessed by weighing each bottle before and after the feeding. Maternal sensitivity and responsiveness to infant cues was objectively assessed using the Nursing Child Assessment Feeding Scale. Mothers were significantly more responsive to infant cues when they used opaque compared to clear bottles (p = .04). There was also a trend for infants to consume significantly less formula when fed from opaque compared to clear bottles (p = .08). Mothers' pressuring feeding style moderated the effect of bottle type on maternal responsiveness to infant cues (p = .02) and infant intake (p = .03). Specifically, mothers who reported higher levels of pressuring feeding were significantly more responsive to their infants' cues (p = .02) and fed their infants significantly less formula when using opaque versus clear bottles (p = .01); no differences were seen for mothers who reported lower levels of pressuring feeding. This study highlights a simple, yet effective intervention for improving the bottle-feeding practices of mothers who have pressuring feeding styles. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. Reduction of 68Ge activity containing liquid waste from 68Ga PET chemistry in nuclear medicine and radiopharmacy by solidification.

    PubMed

    de Blois, Erik; Chan, Ho Sze; Roy, Kamalika; Krenning, Eric P; Breeman, Wouter A P

    PET with 68 Ga from the TiO 2 - or SnO 2 - based 68 Ge/ 68 Ga generators is of increasing interest for PET imaging in nuclear medicine. In general, radionuclidic purity ( 68 Ge vs. 68 Ga activity) of the eluate of these generators varies between 0.01 and 0.001%. Liquid waste containing low amounts of 68 Ge activity is produced by eluting the 68 Ge/ 68 Ga generators and residues from PET chemistry. Since clearance level of 68 Ge activity in waste may not exceed 10 Bq/g, as stated by European Directive 96/29/EURATOM, our purpose was to reduce 68 Ge activity in solution from >10 kBq/g to <10 Bq/g; which implies the solution can be discarded as regular waste. Most efficient method to reduce the 68 Ge activity is by sorption of TiO 2 or Fe 2 O 3 and subsequent centrifugation. The required 10 Bq per mL level of 68 Ge activity in waste was reached by Fe 2 O 3 logarithmically, whereas with TiO 2 asymptotically. The procedure with Fe 2 O 3 eliminates ≥90% of the 68 Ge activity per treatment. Eventually, to simplify the processing a recirculation system was used to investigate 68 Ge activity sorption on TiO 2 , Fe 2 O 3 or Zeolite. Zeolite was introduced for its high sorption at low pH, therefore 68 Ge activity containing waste could directly be used without further interventions. 68 Ge activity containing liquid waste at different HCl concentrations (0.05-1.0 M HCl), was recirculated at 1 mL/min. With Zeolite in the recirculation system, 68 Ge activity showed highest sorption.

  14. Beverages: bottled water. Final rule.

    PubMed

    2009-05-29

    The Food and Drug Administration (FDA) is amending its bottled water regulations to require that bottled water manufacturers test source water for total coliform, as is required for finished bottled water products, and to require, if any coliform organisms are detected in source water, that bottled water manufacturers determine whether any of the coliform organisms are Escherichia coli (E. coli), an indicator of fecal contamination. FDA also is amending its bottled water regulations to require, if any coliform organisms are detected in finished bottled water products, that bottled water manufacturers determine whether any of the coliform organisms are E. coli. FDA also is amending the adulteration provision of the bottled water standard to reflect the possibility of adulteration caused by the presence of filth. Bottled water containing E. coli will be considered adulterated, and source water containing E. coli will not be considered to be of a safe, sanitary quality and will be prohibited from use in the production of bottled water. FDA is also amending its bottled water regulations to require that, before a bottler can use source water from a source that has tested positive for E. coli, the bottler must take appropriate measures to rectify or eliminate the cause of E. coli contamination of that source, and that the bottler must keep records of such actions. Existing regulatory provisions require bottled water manufacturers to keep records of new testing required by this rule. This final rule will ensure that FDA's standards for the minimum quality of bottled water, as affected by fecal contamination, will be no less protective of the public health than those set by the Environmental Protection Agency (EPA) for public drinking water.

  15. Bottle-feeding histories of preterm infants.

    PubMed

    Pickler, R H; Mauck, A G; Geldmaker, B

    1997-01-01

    To describe the bottle-feeding histories of preterm infants and determine physical indices related to and predictive of bottle-feeding initiation and progression. Ex post facto. Academic medical center. A convenience sample of 40 preterm infants without concomitant cardiac, gastrointestinal, or cognitive impairment. Postconceptional age at first bottle-feeding, full bottle-feeding, and discharge. The morbidity rating, using the Neonatal Medical Index (NMI), was most strongly correlated with postconceptional age at first bottle-feeding (r = .34, p < .05), full bottle-feeding (r = .65, p < .01), and discharge (r = .55, p < .05). The morbidity rating also accounted for 12%, 42%, and 30% of the variance in postconceptional age at first bottle-feeding, full bottle-feeding, and discharge, respectively. The NMI may be a useful tool for predicting the initiation and progression of bottle-feeding in preterm infants.

  16. Stopping the Bottle

    MedlinePlus

    ... difficult it can be to break the bottle habit. Longer bottle use may lead to cavities or ... Drinks for Kids Toddlers at the Table: Avoiding Power Struggles View more About Us Contact Us Partners ...

  17. Briquettes of rice husk, polyethylene terephthalate (PET), and dried leaves as implementation of wastes recycling

    NASA Astrophysics Data System (ADS)

    Hariyanto, Sucipto; Usman, Mohammad Nurdianfajar; Citrasari, Nita

    2017-06-01

    This research aim is to determine the best briquettes as implementation of wastes recycle based on scoring method, main component composition, compressive strength, caloric value, water content, vollatile content, and ash content, also the suitability with SNI 01-6235-2000. Main component that used are rice husk, 2mm and 6 mm PET, and dried leaves. Composition variation in this research are marked as K1, K2, K3, K4, and K5 with 2 mm PET plastic and K1, K2, K3, K4, and K5 with 6 mm PET plastic. The total weight of the briquettes is 100 g and divided into 90% main components and 10% tapioca as binder. The compressive strength, caloric value, water content, vollatile content, and ash content were tested according to ASTM D 5865-04, ASTM D 3173-03, ASTM D 3175-02, ASTM D 3174-02. The tested results were used to determine the best briquette by scoring method, and the chosen briquettes is K2 with 6 mm PET plastic. The composition is 70% rice husk, 20% 6 mm PET plastic, and 10% dried leaves with the compressive strength, caloric value, water content, vollatile content, and ash content value is 51,55 kg/cm2; 5123 kal/g; 3,049%; 31,823%, dan 12,869%. The suitable value that meet the criteria according to SNI 01-6235-2000 is compressive strength, caloric value, water content, and ash content.

  18. U.S. Navy Shipboard-Generated Plastic Waste Pilot Recycling Program

    DTIC Science & Technology

    1991-03-01

    2: Recyclable Plastic Items Collected from Lexington Waste at Escambia County MRF Shampoo containers Plastic garbage bags Tyvek suit Shower thongs...bale consisted of polystyrene foam cups, bread bags, bottles, disposable razors, latex gloves, shampoo bottles, and othermiscellaneous items listed in...recent csws telephone survey of recycling firms involved in the separation of mixed 46 plastic bottles, the cost of sorting plastic bottles is

  19. Fluid Dynamics of Bottle Filling

    NASA Astrophysics Data System (ADS)

    McGough, Patrick; Gao, Haijing; Appathurai, Santosh; Basaran, Osman

    2011-11-01

    Filling of bottles is a widely practiced operation in a large number of industries. Well known examples include filling of ``large'' bottles with shampoos and cleaners in the household products and beauty care industries and filling of ``small'' bottles in the pharmaceutical industry. Some bottle filling operations have recently drawn much attention from the fluid mechanics community because of the occurrence of a multitude of complex flow regimes, transitions, and instabilities such as mounding and coiling that occur as a bottle is filled with a fluid. In this talk, we present a primarily computational study of the fluid dynamical challenges that can arise during the rapid filling of bottles. Given the diversity of fluids used in filling applications, we consider four representative classes of fluids that exhibit Newtonian, shear-thinning, viscoelastic, and yield-stress rheologies. The equations governing the dynamics of bottle filling are solved either in their full 3D but axisymmetric form or using the slender-jet approximation.

  20. Bottled Water Mania: Americas Misguided Infatuation with Bottled Water over Tap Water

    DTIC Science & Technology

    2010-05-01

    AU/ACSC/BROWN, S/AY10 AIR COMMAND AND STAFF COLLEGE AIR UNIVERSITY Bottled Water Mania: America’s Misguided...Infatuation with Bottled Water over Tap Water by Seiho P. Brown, LCDR, U.S. Navy A Research Report Submitted to the Faculty In...iii Abstract The purpose of this paper is to analyze the tendency for American people to drink bottled water over tap water even though it costs

  1. Determination of oligomers in virgin and recycled polyethylene terephthalate (PET) samples by UPLC-MS-QTOF.

    PubMed

    Ubeda, Sara; Aznar, Margarita; Nerín, Cristina

    2018-03-01

    An oligomer is a molecule that consists of a few monomer units. It can be formed during polymer manufacturing and also due to polymer degradation processes or even during use conditions. Since oligomers are not included in chemical databases, their identification is a complex process. In this work, the oligomers present in 20 different PET pellet samples have been determined. Two different sample treatment procedures, solvent extraction and total dissolution, were applied in order to select the most efficient one. The analyses were carried out by UPLC-MS-QTOF. The use of high resolution mass spectrometry allowed the structural elucidation of these compounds and their correct identification. The main oligomers identified were cyclic as well as lineal from the first, second, and third series. All of them were composed of terephthalic acid (TPA), diethylene glycol (DEG), and ethylene glycol (EG). Quantitative values were very different in both procedures. In total dissolution of PET samples, the concentration of oligomers was always, at least, 10 times higher than in solvent extraction; some of the compounds were only detected when total dissolution was used. Results showed that the oligomers with the highest concentration values were dimers and trimers, cyclic, as well as lineal, from the first and second series. The oligomer with the maximum concentration value was TPA 2 -EG-DEG that was found in all the samples in a concentration range from 2493 to 19,290 ng/g PET. No differences between virgin and recycled PET were found. Migration experiments were performed in two PET bottles, and results showed the transference of most of these oligomers to a fat food simulant (ethanol 95%). Graphical abstract Graphical abstract of the two procedures developd and optimized for identifying oligomers in PET pellets and in migration form PET bottles.

  2. A three-year clinical evaluation of two-bottle versus one-bottle dentin adhesives.

    PubMed

    Aw, Tar C; Lepe, Xavier; Johnson, Glen H; Mancl, Lloyd A

    2005-03-01

    The authors conducted an in vivo investigation to compare the clinical performance of two commercial one-bottle adhesives and a two-bottle adhesive for restoration of noncarious cervical lesions (NCCLs). The patient pool consisted of 57 patients and 171 teeth (three teeth per patient), with one NCCL per tooth. Each patient received three resin-based composite restorations, each with a different adhesive: one tooth with a two-bottle, water-based adhesive as the control; another tooth with a one-bottle, ethanol-based adhesive; and a third tooth with a one-bottle, solvent-free adhesive. The authors assessed restorations in terms of retention, marginal integrity, margin discoloration and air sensitivity at baseline, six months, one year, two years and three years after initial placement. The retention rates at 36 months were 88 percent for the first adhesive, 81 percent for the second adhesive and 90 percent for the third adhesive. No statistically significant differences in retention rates could be shown, with 86 percent of restorations retained overall. Measures of marginal integrity, marginal discoloration and sensitivity also had no statistically significant differences between the three adhesives (P > .05). All three adhesives performed with acceptable outcomes after a 36-month period, with small differences between the one- and two-bottle systems and between the various solvents. Retention rate was moderately high and air sensitivity was markedly reduced; however, superficial marginal discoloration and marginal degradation was notable. Certain lesion, tooth and patient characteristics may predispose restorations to retention failure. The type of solvent may not be a major factor in retention of Class V restorations in NCCLs. Both single-bottle adhesives and conventional two-bottle adhesives performed acceptably.

  3. Post-consumer contamination in high-density polyethylene (HDPE) milk bottles and the design of a bottle-to-bottle recycling process.

    PubMed

    Welle, F

    2005-10-01

    Six hundred conventional recycled HDPE flake samples, which were recollected and sorted in the UK, were screened for post-consumer contamination levels. Each analysed sample consisted of 40-50 individual flakes so that the amount of analysed individual containers was in the range 24,000-30,000 post-consumer milk bottles. Predominant contaminants in hot-washed flake samples were unsaturated oligomers, which can be also be found in virgin high-density polyethylene (HDPE) pellet samples used for milk bottle production. In addition, the flavour compound limonene, the degradation product of antioxidant additives di-tert-butylphenol and low amounts of saturated oligomers were found in higher concentrations in the post-consumer samples in comparison with virgin HDPE. However, the overall concentrations in post-consumer recycled samples were similar to or lower than concentration ranges in comparison with virgin HDPE. Contamination with other HDPE untypical compounds was rare and was in most cases related to non-milk bottles, which are <2.1% of the input material of the recycling process. The maximum concentration found in one sample of 1 g was estimated as 130 mg kg(-1), which corresponds to a contamination of 5200-6500 mg kg(-1) in the individual bottle. The recycling process investigated was based on an efficient sorting process, a hot-washing of the ground bottles, and a further deep-cleaning of the flakes with high temperatures and vacuum. Based on the fact that the contamination levels of post-consumer flake samples are similar to virgin HDPE and on the high cleaning efficiency of the super-clean recycling process especially for highly volatile compounds, the recycling process investigated is suitable for recycled post-consumer HDPE bottles for direct food-contact applications. However, hand-picking after automatically sorting is recommended to decrease the amount of non-milk bottles. The conclusions for suitability are valid, provided that the migration testing of

  4. Development of an LC-MS/MS method for studying migration characteristics of acetaldehyde in polyethylene terephthalate (PET)-packed mineral water.

    PubMed

    Baumjohann, Nina; Harms, Diedrich

    2015-01-01

    During storage, acetaldehyde migration from polyethylene terephthalate (PET) bottles can affect the quality of mineral water even in the low µg l(-1) range negatively, as it features a fruity or plastic-like off-flavour. For a sensitive and fast analysis of acetaldehyde in mineral water, a new analysis method of 2,4-dinitrophenylhydrazine (DNPH) derivatisation followed by HPLC-electrospray tandem mass spectrometry (ESI-MS/MS) was developed. Acetaldehyde was directly derivatised in the mineral water sample avoiding extraction and/or pre-concentration steps and then analysed by reversed-phase HPLC-ESI-MS/MS using multiple reaction monitoring mode (MRM). Along with method development, the optimum molar excess of DNPH in contrast to acetaldehyde was studied for the mineral water matrix, because no specific and robust data were yet available for this critical parameter. Best results were obtained by using a calibration via the derivatisation reaction. Without any analyte enrichment or extraction, an LOD of 0.5 µg l(-1) and an LOQ of 1.9 µg l(-1) were achieved. Using the developed method, mineral water samples packed in PET bottles from Germany were analysed and the correlation between the acetaldehyde concentration and other characteristics of the samples was evaluated illustrating the applicability of the method. Besides a relationship between bottle size and CO2 content of the mineral water and acetaldehyde migration, a correlation with acetaldehyde migration and the material composition of the bottle, e.g. recycled PET, was noted. Investigating the light influence on the acetaldehyde migration with a newly developed, reproducible light exposure setup, a significant increase of the acetaldehyde concentration in carbonated mineral water samples was observed.

  5. Effect of bottling and storage on the migration of plastic constituents in Spanish bottled waters.

    PubMed

    Guart, Albert; Bono-Blay, Francisco; Borrell, Antonio; Lacorte, Silvia

    2014-08-01

    Bottled water is packaged in either glass or, to a large extent, in plastic bottles with metallic or plastic caps of different material, shape and colour. Plastic materials are made of one or more monomers and several additives that can eventually migrate into water, either during bottle manufacturing, water filling or storage. The main objective of the present study was to carry out a comprehensive assessment of the quality of the Spanish bottled water market in terms of (i) migration of plastic components or additives during bottling and during storage and (ii) evaluation of the effect of the packaging material and bottle format on the migration potential. The compounds investigated were 5 phthalates, diethylhexyl adipate, alkylphenols and bisphenol A. A set of 362 bottled water samples corresponding to 131 natural mineral waters and spring waters sources and 3 treated waters of several commercial brands were analysed immediately after bottling and after one-year storage (a total of 724 samples). Target compounds were detected in 5.6% of the data values, with diethyl hexyl phthalate and bisphenol A being the most ubiquitous compounds detected. The total daily intake was estimated and a comparison with reference values was indicated. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. Nuclear Archeology in a Bottle: Evidence of Pre-Trinity U.S. Weapons Activities from a Waste Burial Site

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schwantes, Jon M.; Douglas, Matthew; Bonde, Steven E.

    2009-02-15

    During World War II, the Hanford Site in Washington was chosen for plutonium production. In 2004, a bottle containing a sample of plutonium was recovered from a Hanford waste trench. Isotopic age dating indicated the sample was separated from the fuel pellet 64 ±2.8 years earlier. Detectable products of secondary nuclear reactions, such as 22Na, proved useful as 1) a detectable analog for alpha emitting actinides, 2) an indicator of sample splitting, and 3) a measure of the time since sample splitting. The sample origin was identified as the X-10 reactor, Oak Ridge, TN. Corroborated by historical documents, we concludedmore » this sample was part of the first batch of Pu separated at T-Plant, Hanford, the world’s first industrial-scale reprocessing facility, on December 9, 1944.« less

  7. Constructing a Plastic Bottle Wind Turbine as a Practical Aid for Learning about Using Wind Energy to Generate Electricity

    ERIC Educational Resources Information Center

    Appleyard, S. J.

    2009-01-01

    A simple horizontal axis wind turbine can be easily constructed using a 1.5 l PET plastic bottle, a compact disc and a small dynamo. The turbine operates effectively at low wind speeds and has a rotational speed of 500 rpm at a wind speed of about 14 km h[superscript -1]. The wind turbine can be used to demonstrate the relationship between open…

  8. Utilization of polyethylene terephthalate (PET) in asphalt pavement: A review

    NASA Astrophysics Data System (ADS)

    Ahmad, A. F.; Razali, A. R.; Razelan, I. S. M.

    2017-05-01

    The quantity of plastics used throughout the world is increasing every year. Municipal solid wastes (MSW), manufacturing processes and service industries produce a lot of waste plastic materials. The increasing awareness among consumers about the environment has contributed to the concerns over disposal of generated wastes. The growing number of plastic materials every year and limited landfill conditions causes many alternatives exist for the disposal of plastic waste. This paper provides a summary of the study on the utilization of polyethylene terephthalate (PET) in road construction. Data from researcher show that PET can improve some properties of modified asphalt mixture. Having considered the economic and environmental prudent angles, utilization of PET as an additive to asphalt mixture is suitable to be used for road pavement.

  9. 27 CFR 19.382 - Bottling tanks.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Bottling tanks. 19.382... Manufacture of Articles Bottling, Packaging, and Removal of Products § 19.382 Bottling tanks. All spirits shall be bottled from tanks listed and certified as accurately calibrated in the notice of registration...

  10. Evaluation of scatter limitation correction: a new method of correcting photopenic artifacts caused by patient motion during whole-body PET/CT imaging.

    PubMed

    Miwa, Kenta; Umeda, Takuro; Murata, Taisuke; Wagatsuma, Kei; Miyaji, Noriaki; Terauchi, Takashi; Koizumi, Mitsuru; Sasaki, Masayuki

    2016-02-01

    Overcorrection of scatter caused by patient motion during whole-body PET/computed tomography (CT) imaging can induce the appearance of photopenic artifacts in the PET images. The present study aimed to quantify the accuracy of scatter limitation correction (SLC) for eliminating photopenic artifacts. This study analyzed photopenic artifacts in (18)F-fluorodeoxyglucose ((18)F-FDG) PET/CT images acquired from 12 patients and from a National Electrical Manufacturers Association phantom with two peripheral plastic bottles that simulated the human body and arms, respectively. The phantom comprised a sphere (diameter, 10 or 37 mm) containing fluorine-18 solutions with target-to-background ratios of 2, 4, and 8. The plastic bottles were moved 10 cm posteriorly between CT and PET acquisitions. All PET data were reconstructed using model-based scatter correction (SC), no scatter correction (NSC), and SLC, and the presence or absence of artifacts on the PET images was visually evaluated. The SC and SLC images were also semiquantitatively evaluated using standardized uptake values (SUVs). Photopenic artifacts were not recognizable in any NSC and SLC image from all 12 patients in the clinical study. The SUVmax of mismatched SLC PET/CT images were almost equal to those of matched SC and SLC PET/CT images. Applying NSC and SLC substantially eliminated the photopenic artifacts on SC PET images in the phantom study. SLC improved the activity concentration of the sphere for all target-to-background ratios. The highest %errors of the 10 and 37-mm spheres were 93.3 and 58.3%, respectively, for mismatched SC, and 73.2 and 22.0%, respectively, for mismatched SLC. Photopenic artifacts caused by SC error induced by CT and PET image misalignment were corrected using SLC, indicating that this method is useful and practical for clinical qualitative and quantitative PET/CT assessment.

  11. 27 CFR 4.26 - Estate bottled.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... OF THE TREASURY LIQUORS LABELING AND ADVERTISING OF WINE Standards of Identity for Wine § 4.26 Estate bottled. (a) Conditions for use. The term Estate bottled may be used by a bottling winery on a wine label only if the wine is labeled with a viticultural area appellation of origin and the bottling winery: (1...

  12. 27 CFR 4.26 - Estate bottled.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... OF THE TREASURY LIQUORS LABELING AND ADVERTISING OF WINE Standards of Identity for Wine § 4.26 Estate bottled. (a) Conditions for use. The term Estate bottled may be used by a bottling winery on a wine label only if the wine is labeled with a viticultural area appellation of origin and the bottling winery: (1...

  13. The Blue Bottle Revisited.

    ERIC Educational Resources Information Center

    Vandaveer, Walter R., IV; Mosher, Mel

    1997-01-01

    Presents a modification of the classic Blue Bottle demonstration that involves the alkaline glucose reduction of methylene blue. Uses other indicators in the classic Blue Bottle to produce a rainbow of colors. (JRH)

  14. Material and Structural Performance Evaluations of Hwangtoh Admixtures and Recycled PET Fiber-Added Eco-Friendly Concrete for CO₂ Emission Reduction.

    PubMed

    Koo, Bon-Min; Kim, Jang-Ho Jay; Kim, Sung-Bae; Mun, Sungho

    2014-08-19

    In order to reduce carbon dioxide (CO₂) emissions and produce an eco-friendly construction material, a type of concrete that uses a minimal amount of cement, yet still retains equivalent properties to ordinary cement concrete, has been developed and studied all over the world. Hwangtoh, a type of red clay broadly deposited around the world, has traditionally been considered an eco-friendly construction material, with bonus advantages of having health and cost benefits. Presently, Hwangtoh is not commonly used as a modern construction material due to properties such as low strength and high rates of shrinkage cracking. Recent studies, however, have shown that Hwangtoh can be used as a mineral admixture to improve the strength of concrete. In addition, polyethylene terephthalate (PET) fibers recycled from PET bottle waste can be used to control shrinkage cracks in Hwangtoh concrete. Therefore, in this study, performance verification is conducted on newly developed Hwangtoh concrete mixed with short recycled PET fibers. The results show that Hwangtoh concrete has compressive strength, elastic modulus, and pH properties that are similar to these features in ordinary cement concrete. The properties of carbonation depth and creep strain of Hwangtoh concrete, however, are larger and smaller, respectively, than in ordinary cement concrete. According to flexural tests, reinforced concrete (RC) specimens cast with Hwangtoh admixtures (with and without PET fibers) possess similar or better capacities than ordinary RC specimens. The addition of PET fibers significantly improves the structural ductility of RC specimens under normal environmental conditions. However, the implementations of the concrete in aggressive environment must be carefully considered, since a previous study result indicates degradation of its durability performance in aggressive environments, such as seawater [1]. The results of this study validate the possibility of using eco-friendly Hwangtoh concrete

  15. Automatic classification of bottles in crates

    NASA Astrophysics Data System (ADS)

    Aas, Kjersti; Eikvil, Line; Bremnes, Dag; Norbryhn, Andreas

    1995-03-01

    This paper presents a statistical method for classification of bottles in crates for use in automatic return bottle machines. For the automatons to reimburse the correct deposit, a reliable recognition is important. The images are acquired by a laser range scanner coregistering the distance to the object and the strength of the reflected signal. The objective is to identify the crate and the bottles from a library with a number of legal types. The bottles with significantly different size are separated using quite simple methods, while a more sophisticated recognizer is required to distinguish the more similar bottle types. Good results have been obtained when testing the method developed on bottle types which are difficult to distinguish using simple methods.

  16. Prototyping the Use of Dispersion Models to Predict Ground Concentrations During Burning of Deployed Military Waste

    DTIC Science & Technology

    2012-03-22

    Fabric 3.85% Polypropylene (PP) (Class 5 plastics, soda cups, yogurt boxes, syrup bottles, prescription bottles) 1.32% Yard waste 5.67% PVC (Class 3...plastics, milk jugs) 1.23% Cardboard 31.33% Polypropylene (PP) (Class 5 plastics, soda cups, yogurt boxes, syrup bottles, prescription bottles) 0.62

  17. An upright eyedrop bottle: accuracy, usage of excess drops, and contamination compared to a conventional bottle.

    PubMed

    Davies, Isaiah J; Brown, Ninita H; Wen, Joanne C; Stinnett, Sandra S; Kubelick, Kelsey; Patel, Roma P; Benokraitis, Kristin L; Greene, Latoya; Cheek, Curry; Muir, Kelly W

    2016-01-01

    This study tested the feasibility of using an upright eyedrop bottle (UEB), a device designed to assist patients with eyedrop placement without reclining their head. Experienced eyedrop users were enrolled who answered "yes" to the question, "Do you ever have trouble getting your eyedrops in?" After being shown a multimedia presentation and answering a questionnaire regarding eyedrop usage, participants were observed instilling eyedrops. Participants were instructed to instill a single eyedrop in each eye with both a standard bottle and the UEB. They repeated this process three times. With each trial, the amount of time taken to instill drops was recorded, as well as whether a drop landed in the eye (accuracy), if excess drops were used, and if the bottle tip was contaminated. Forty participants were enrolled, with an average age of 72.4±8.9 years; the majority were females (24 females). Thirty-four participants had been using eyedrops for at least 1 year. The time required to instill eyedrops was significantly less with the UEB in the second and third trials. There was no difference in accuracy between the conventional bottle and the UEB in the left or right eye in any trials. Significantly more participants used excess number of drops while using the conventional bottle in both the left and right eyes in all three trials. The bottle tip was never contaminated with the UEB. Depending on the trial and the eye, the conventional bottle was contaminated by between 42% and 53% of participants. The UEB has the potential to assist patients with eyedrop placement. Although there was no difference in accuracy between the UEB and the conventional bottle, the UEB was associated with less use of excess drops and less contamination of the bottle tip, compared to the conventional bottle.

  18. Material and Structural Performance Evaluations of Hwangtoh Admixtures and Recycled PET Fiber-Added Eco-Friendly Concrete for CO2 Emission Reduction

    PubMed Central

    Koo, Bon-Min; Kim, Jang-Ho Jay; Kim, Sung-Bae; Mun, Sungho

    2014-01-01

    In order to reduce carbon dioxide (CO2) emissions and produce an eco-friendly construction material, a type of concrete that uses a minimal amount of cement, yet still retains equivalent properties to ordinary cement concrete, has been developed and studied all over the world. Hwangtoh, a type of red clay broadly deposited around the world, has traditionally been considered an eco-friendly construction material, with bonus advantages of having health and cost benefits. Presently, Hwangtoh is not commonly used as a modern construction material due to properties such as low strength and high rates of shrinkage cracking. Recent studies, however, have shown that Hwangtoh can be used as a mineral admixture to improve the strength of concrete. In addition, polyethylene terephthalate (PET) fibers recycled from PET bottle waste can be used to control shrinkage cracks in Hwangtoh concrete. Therefore, in this study, performance verification is conducted on newly developed Hwangtoh concrete mixed with short recycled PET fibers. The results show that Hwangtoh concrete has compressive strength, elastic modulus, and pH properties that are similar to these features in ordinary cement concrete. The properties of carbonation depth and creep strain of Hwangtoh concrete, however, are larger and smaller, respectively, than in ordinary cement concrete. According to flexural tests, reinforced concrete (RC) specimens cast with Hwangtoh admixtures (with and without PET fibers) possess similar or better capacities than ordinary RC specimens. The addition of PET fibers significantly improves the structural ductility of RC specimens under normal environmental conditions. However, the implementations of the concrete in aggressive environment must be carefully considered, since a previous study result indicates degradation of its durability performance in aggressive environments, such as seawater [1]. The results of this study validate the possibility of using eco-friendly Hwangtoh concrete

  19. An experimental study on stabilization of Pekan clay using polyethylene and polypropylene

    NASA Astrophysics Data System (ADS)

    Zukri, Azhani; Nazir, Ramli; Mender, Fatin Nabilah

    2017-10-01

    Many countries are expressing concern over the growing issues of polyethylene terephthalate (PET) bottles and polypropylene (PP) products made by the household sector. The rapid increase in the generation of plastic waste all around the world is due to the economic development and population growth. PP is the world's second-most widely produced synthetic plastic, after polyethylene. Statistics show that nearly 50% of the municipal solid waste in Malaysia comes from the institutional, industrial, residential, and construction waste. This paper presents the results of an investigation on the utilisation of fibres as products of PET bottles and PP products in order to improve the engineering properties of clay soil in Pekan. The soil samples were taken from Kampung Tanjung Medang, Pekan, Pahang. The basic properties of the clay soil were determined as follows; optimum moisture content: 32.5%, maximum dry density: 13.43 kN/m3, specific gravity: 2.51, liquid limit: 74.67%, plastic limit: 45.98%, and plasticity index: 28.69%. This investigation concentrates on the shear strength of the reinforced clay soils with PET and PP in random orientation. The reinforced soil samples were subjected to unconfined compression test (UCT) to differentiate their shear strength with that of the unreinforced soil. The tests found that the waste fibres (PET and PP) improved the strength properties of the Pekan clayey soils. The unconfined compressive strength (UCS) value increased with the increasing percentage of PET fibre and reached the optimum content at 10% reinforcement, where it showed the highest improvement of 365 kN/m2 from 325 kN/m2 and depleted when the optimum content reached 20% reinforcement. For PP fibre, the reinforced soil showed the highest UCS at 20% reinforcement with the improvement of 367 kN/m2. The study concluded that the PET and PP fibres can be utilised successfully as reinforcement materials for the stabilisation of clayey soils. The use of these waste compounds

  20. CHARGE BOTTLE FOR A MASS SEPARATOR

    DOEpatents

    Davidson, P.H.

    1959-07-01

    Improved mass separator charge bottles are described for containing a dense charge of a chemical compound of copper, nickel, lead or other useful substance which is to be vaporized, and to the method of utilizing such improvcd charge bottles so that the chemical compound is vaporized from the under surface of the charge and thus permits the non-volatile portion thereof to fall to the bottom of the charge bottle where it does not form an obstacle to further evaporation. The charge bottle comprises a vertically disposed cylindrical portion, an inner re-entrant cylindrical portion extending axially and downwardly into the same from the upper end thereof, and evaporative source material in the form of a chemical compound compacted within the upper annular pontion of the charge bottle formed by the re-entrant cylindrical portion, whereby vapor from the chemical compound will pass outwardly from the charge bottle through an apertured closure.

  1. 27 CFR 24.256 - Bottle aging wine.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Bottle aging wine. 24.256... OF THE TREASURY LIQUORS WINE Storage, Treatment and Finishing of Wine Bottling, Packing, and Labeling of Wine § 24.256 Bottle aging wine. Wine bottled or packed and stored for the purpose of aging need...

  2. Scatter Correction with Combined Single-Scatter Simulation and Monte Carlo Simulation Scaling Improved the Visual Artifacts and Quantification in 3-Dimensional Brain PET/CT Imaging with 15O-Gas Inhalation.

    PubMed

    Magota, Keiichi; Shiga, Tohru; Asano, Yukari; Shinyama, Daiki; Ye, Jinghan; Perkins, Amy E; Maniawski, Piotr J; Toyonaga, Takuya; Kobayashi, Kentaro; Hirata, Kenji; Katoh, Chietsugu; Hattori, Naoya; Tamaki, Nagara

    2017-12-01

    In 3-dimensional PET/CT imaging of the brain with 15 O-gas inhalation, high radioactivity in the face mask creates cold artifacts and affects the quantitative accuracy when scatter is corrected by conventional methods (e.g., single-scatter simulation [SSS] with tail-fitting scaling [TFS-SSS]). Here we examined the validity of a newly developed scatter-correction method that combines SSS with a scaling factor calculated by Monte Carlo simulation (MCS-SSS). Methods: We performed phantom experiments and patient studies. In the phantom experiments, a plastic bottle simulating a face mask was attached to a cylindric phantom simulating the brain. The cylindric phantom was filled with 18 F-FDG solution (3.8-7.0 kBq/mL). The bottle was filled with nonradioactive air or various levels of 18 F-FDG (0-170 kBq/mL). Images were corrected either by TFS-SSS or MCS-SSS using the CT data of the bottle filled with nonradioactive air. We compared the image activity concentration in the cylindric phantom with the true activity concentration. We also performed 15 O-gas brain PET based on the steady-state method on patients with cerebrovascular disease to obtain quantitative images of cerebral blood flow and oxygen metabolism. Results: In the phantom experiments, a cold artifact was observed immediately next to the bottle on TFS-SSS images, where the image activity concentrations in the cylindric phantom were underestimated by 18%, 36%, and 70% at the bottle radioactivity levels of 2.4, 5.1, and 9.7 kBq/mL, respectively. At higher bottle radioactivity, the image activity concentrations in the cylindric phantom were greater than 98% underestimated. For the MCS-SSS, in contrast, the error was within 5% at each bottle radioactivity level, although the image generated slight high-activity artifacts around the bottle when the bottle contained significantly high radioactivity. In the patient imaging with 15 O 2 and C 15 O 2 inhalation, cold artifacts were observed on TFS-SSS images, whereas

  3. 21 CFR 165.110 - Bottled water.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    .... (3) Physical quality. Bottled water shall, when a composite of analytical units of equal volume from.... 1 (4) Chemical quality. (i)(A) Bottled water shall, when a composite of analytical units of equal... bottled water, when a composite of analytical units of equal volume from a sample is examined by the...

  4. Community challenges when using large plastic bottles for Solar Energy Disinfection of Water (SODIS).

    PubMed

    Borde, Preeti; Elmusharaf, Khalifa; McGuigan, Kevin G; Keogh, Michael B

    2016-09-05

    Communities living in developing countries as well as populations affected by natural or man-made disasters can be left at great risk from water related diseases, especially those spread through the faecal-oral route. Conventional water treatments such as boiling and chlorination can be effective but may prove costly for impoverished communities. Solar water disinfection (SODIS) has been shown to be a cheap and effective way for communities to treat their water. The exposure to sunlight is typically carried out in small volume plastic beverage bottles (up to 2 l). Given the water requirements of consumption and basic personal hygiene, this may not always meet the needs of communities. Recent work has shown 19-L plastic water dispenser containers to be effective SODIS reactors, comparable in efficacy to PET bottles. In this paper we outline the need for studying SODIS in large volumes and discuss 4 main associated challenges. Apart from clean water needed for consumption, access to adequate water is essential for sanitation and hygiene. Contamination of treated water through unwashed hands or vessels contributes heavily to the spread of water borne pathogens in communities. Traditional water treatments such as boiling and chlorination can be effective but may prove financially burdensome for low income communities. SODIS in large vessels could be used as a simple method to meet water requirements in low income and disaster affected populations. However, there have been some concerns associated with the conventional SODIS method; we identify the main ones to be: (1) cold or cloudy weather; (2) the fear of leaching in plastic bottles; (3) water turbidity, and; (4) community acceptance. The application of SODIS in large bottles like WDCs has the potential to be an efficient and cost effective method of disinfecting water, either for consumption until more rigorous water treatments can be put in place, or for sanitation and hygiene to curb the spread of fecal

  5. 27 CFR 19.352 - Bottling tanks.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2013-04-01 2013-04-01 false Bottling tanks. 19.352..., Packaging, and Removal of Products § 19.352 Bottling tanks. Generally, a proprietor must bottle all spirits from tanks that are listed in the notice of registration and have been certified as accurate. However...

  6. 27 CFR 19.352 - Bottling tanks.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2011-04-01 2011-04-01 false Bottling tanks. 19.352..., Packaging, and Removal of Products § 19.352 Bottling tanks. Generally, a proprietor must bottle all spirits from tanks that are listed in the notice of registration and have been certified as accurate. However...

  7. 27 CFR 19.352 - Bottling tanks.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2012-04-01 2012-04-01 false Bottling tanks. 19.352..., Packaging, and Removal of Products § 19.352 Bottling tanks. Generally, a proprietor must bottle all spirits from tanks that are listed in the notice of registration and have been certified as accurate. However...

  8. 27 CFR 19.352 - Bottling tanks.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2014-04-01 2014-04-01 false Bottling tanks. 19.352..., Packaging, and Removal of Products § 19.352 Bottling tanks. Generally, a proprietor must bottle all spirits from tanks that are listed in the notice of registration and have been certified as accurate. However...

  9. 21 CFR 868.5220 - Blow bottle.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Blow bottle. 868.5220 Section 868.5220 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5220 Blow bottle. (a) Identification. A blow bottle is a device...

  10. 21 CFR 868.5220 - Blow bottle.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Blow bottle. 868.5220 Section 868.5220 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5220 Blow bottle. (a) Identification. A blow bottle is a device...

  11. 21 CFR 868.5220 - Blow bottle.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Blow bottle. 868.5220 Section 868.5220 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5220 Blow bottle. (a) Identification. A blow bottle is a device...

  12. 21 CFR 868.5220 - Blow bottle.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Blow bottle. 868.5220 Section 868.5220 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5220 Blow bottle. (a) Identification. A blow bottle is a device...

  13. Health beliefs about bottled water: a qualitative study.

    PubMed

    Ward, Lorna A; Cain, Owen L; Mullally, Ryan A; Holliday, Kathryn S; Wernham, Aaron G H; Baillie, Paul D; Greenfield, Sheila M

    2009-06-19

    There has been a consistent rise in bottled water consumption over the last decade. Little is known about the health beliefs held by the general public about bottled water as this issue is not addressed by the existing quantitative literature. The purpose of this study was to improve understanding of the public's health beliefs concerning bottled mineral water, and the extent to which these beliefs and other views they hold, influence drinking habits. A qualitative study using semi-structured interviews, with 23 users of the Munrow Sports Centre on the University of Birmingham campus. Health beliefs about bottled water could be classified as general or specific beliefs. Most participants believed that bottled water conferred general health benefits but were unsure as to the nature of these. In terms of specific health beliefs, the idea that the minerals in bottled water conferred a health benefit was the most commonly cited. There were concerns over links between the plastic bottle itself and cancer. Participants believed that bottled water has a detrimental effect on the environment. Convenience, cost and taste were influential factors when making decisions as to whether to buy bottled water; health beliefs were unimportant motivating factors. The majority of participants believed that bottled water has some health benefits. However, these beliefs played a minor role in determining bottled water consumption and are unlikely to be helpful in explaining recent trends in bottled water consumption if generalised to the UK population. The health beliefs elicited were supported by scientific evidence to varying extents. Most participants did not feel that bottled water conferred significant, if any, health benefits over tap water.

  14. Health beliefs about bottled water: a qualitative study

    PubMed Central

    Ward, Lorna A; Cain, Owen L; Mullally, Ryan A; Holliday, Kathryn S; Wernham, Aaron GH; Baillie, Paul D; Greenfield, Sheila M

    2009-01-01

    Background There has been a consistent rise in bottled water consumption over the last decade. Little is known about the health beliefs held by the general public about bottled water as this issue is not addressed by the existing quantitative literature. The purpose of this study was to improve understanding of the public's health beliefs concerning bottled mineral water, and the extent to which these beliefs and other views they hold, influence drinking habits. Methods A qualitative study using semi-structured interviews, with 23 users of the Munrow Sports Centre on the University of Birmingham campus. Results Health beliefs about bottled water could be classified as general or specific beliefs. Most participants believed that bottled water conferred general health benefits but were unsure as to the nature of these. In terms of specific health beliefs, the idea that the minerals in bottled water conferred a health benefit was the most commonly cited. There were concerns over links between the plastic bottle itself and cancer. Participants believed that bottled water has a detrimental effect on the environment. Convenience, cost and taste were influential factors when making decisions as to whether to buy bottled water; health beliefs were unimportant motivating factors. Conclusion The majority of participants believed that bottled water has some health benefits. However, these beliefs played a minor role in determining bottled water consumption and are unlikely to be helpful in explaining recent trends in bottled water consumption if generalised to the UK population. The health beliefs elicited were supported by scientific evidence to varying extents. Most participants did not feel that bottled water conferred significant, if any, health benefits over tap water. PMID:19545357

  15. Hybrid radio-frequency/direct-current plasma-enhanced chemical vapor deposition system for deposition on inner surfaces of polyethylene terephthalate bottles

    NASA Astrophysics Data System (ADS)

    Li, Jing; Tian, Xiubo; Gong, Chunzhi; Yang, Shiqin; Fu, Ricky K. Y.; Chu, Paul K.

    2009-12-01

    A hybrid radio-frequency (rf)/direct-current (dc) system has been developed to control the biasing effects during deposition of diamondlike carbon (DLC) films onto the inner wall of polyethylene terephthalate (PET) bottles. An additional dc bias is coupled to the rf electrode to produce the effect of equivalent rf self-biasing. This allows more flexible control of the deposition of the DLC films which are intended to improve the gas barrier characteristics. The experimental results demonstrate that the additional dc bias improves the adhesion strength between the DLC film and PET, although the enhancement in the gas barrier properties is not significantly larger compared to the one without dc bias. The apparatus and methodology have practical importance in the food and beverage industry.

  16. Effects of storage temperature and duration on release of antimony and bisphenol A from polyethylene terephthalate drinking water bottles of China.

    PubMed

    Fan, Ying-Ying; Zheng, Jian-Lun; Ren, Jing-Hua; Luo, Jun; Cui, Xin-Yi; Ma, Lena Q

    2014-09-01

    We investigated effects of storage temperature and duration on release of antimony (Sb) and bisphenol A (BPA) from 16 brands of polyethylene terephthalate (PET) drinking water bottles in China. After 1-week storage, Sb release increased from 1.88-8.32 ng/L at 4 °C, to 2.10-18.4 ng/L at 25 °C and to 20.3-2604 ng/L at 70 °C. The corresponding releases for BPA were less at 0.26-18.7, 0.62-22.6, and 2.89-38.9 ng/L. Both Sb and BPA release increased with storage duration up to 4-week, but their releasing rates decreased with storage time, indicating that Sb and BPA release from PET bottles may become stable under long term storage. Human health risk was evaluated based on the worst case, i.e., storage at 70 °C for 4-week. Chronic daily intake (CDI) caused by BPA release was below USEPA regulation, Sb release in one brand exceeded USEPA regulated CDI (400 ng/kg bw/d) with values of 409 and 1430 ng/kg bw/d for adult and children. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. Oscillations in a half-empty bottle

    NASA Astrophysics Data System (ADS)

    Bourges, Andréane; Chardac, Amélie; Caussarieu, Aude; Plihon, Nicolas; Taberlet, Nicolas

    2018-02-01

    When a half-empty bottle of water is pushed to roll on a flat surface, the oscillations of the fluid inside the bottle induce an overall jerky motion. These velocity fluctuations of the bottle are studied through simple laboratory experiments accessible to undergraduate students and can help them to grasp fundamental concepts in mechanics and hydrodynamics. We first demonstrate through an astute experiment that the rotation of the fluid and the bottle is decoupled. The equations of motion are then derived using a mechanical approach, while the hydrodynamics of the fluid motion is explained. Finally, the theory is tested against two benchmark experiments.

  18. Mouse taste preference tests: why only two bottles?

    PubMed

    Tordoff, Michael G; Bachmanov, Alexander A

    2003-05-01

    Two-bottle tests have been used extensively to measure the preference for taste and nutrient solutions but there has been little work with tests involving more than two bottles. Here, we compare the results obtained in two-bottle tests with those obtained in three- and six-bottle tests. In Experiment 1, we measured the preferences for 2 mM saccharin, 50 mM citric acid, 0.3 mM quinine hydrochloride and 75 mM NaCl displayed by 129X1/SvJ (129) and C57BL/6J (B6) mice. Mice drank more taste solution when they received two bottles providing taste solution and one providing water than when they received either a standard two-bottle test or two bottles providing water and one providing taste solution. The three-bottle tests also revealed the left spout side preferences of the 129 strain and were generally better at distinguishing between the 129 and B6 strains (i.e. were more sensitive) than were the two-bottle tests. In Experiment 2, we measured intakes and preferences in tests with six bottles, with one, two, three, four or five containing 75 mM NaCl and the rest containing water. NaCl preferences were monotonically related to the number of NaCl spouts available. A follow-up experiment found similar results whether the index of ingestion was volume intakes or licks. This argues that spillage cannot account for the effect of spout number on taste solution intake. Together, the results suggest that (i) the number of bottles of taste solution and water has a profound influence on taste solution intake and preference, and (ii) three-bottle tests may be more sensitive than two-bottle tests in many circumstances.

  19. Mouse Taste Preference Tests: Why Only Two Bottles?

    PubMed Central

    Tordoff, Michael G.; Bachmanov, Alexander A.

    2008-01-01

    Two-bottle tests have been used extensively to measure the preference for taste and nutrient solutions but there has been little work with tests involving more than two bottles. Here, we compare the results obtained in two-bottle tests with those obtained in three- and six-bottle tests. In Experiment 1, we measured the preferences for 2 mM saccharin, 50 mM citric acid, 0.3 mM quinine hydrochloride and 75 mM NaCl displayed by 129X1/SvJ (129) and C57BL/6J (B6) mice. Mice drank more taste solution when they received two bottles providing taste solution and one providing water than when they received either a standard two-bottle test or two bottles providing water and one providing taste solution. The three-bottle tests also revealed the left spout side preferences of the 129 strain and were generally better at distinguishing between the 129 and B6 strains (i.e. were more sensitive) than were the two-bottle tests. In Experiment 2, we measured intakes and preferences in tests with six bottles, with one, two, three, four or five containing 75 mM NaCl and the rest containing water. NaCl preferences were monotonically related to the number of NaCl spouts available. A follow-up experiment found similar results whether the index of ingestion was volume intakes or licks. This argues that spillage cannot account for the effect of spout number on taste solution intake. Together, the results suggest that (i) the number of bottles of taste solution and water has a profound influence on taste solution intake and preference, and (ii) three-bottle tests may be more sensitive than two-bottle tests in many circumstances. PMID:12771018

  20. 27 CFR 25.142 - Bottles.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... TREASURY LIQUORS BEER Marks, Brands, and Labels § 25.142 Bottles. (a) Label requirements. Each bottle of... brewer's name, trade name or brand name includes the name of a city which is not the place where the beer...

  1. Powder Production From Waste Polyethylene Terephthalate (PET) Water Bottles

    DTIC Science & Technology

    2014-06-01

    10 5. References 1. Van Brederode, R. A.; Steinkamp, R. A. Crosslinkable Polymer Powder and Laminate . U.S. Patent 42256560A, 1980, http...16. Parquette, B.; Giri, A.; Daniel, J.; O’Brien,D. J.; Brennan,S.; Cho, K.; Tzeng, J. Cryomilling of Thermoplastic Powder for Prepreg Applications

  2. Phthalates residues in plastic bottled waters.

    PubMed

    Al-Saleh, Iman; Shinwari, Neptune; Alsabbaheen, Ammar

    2011-08-01

    This study was conducted to determine the presence of phthalates in 10 different brands of bottled water available in Saudi markets and stored under different conditions. Dimethyl phthalate (DMP), diethylphthalate (DEP), di-n-butyl phthalate (DBP), benzyl butyl phthalate (BBP) and diethyl hexyl phthalate (DEHP) were measured by headspace solid-phase microextraction followed by gas chromatography- mass spectrometer detector. Most of these phthalates were detected in the selected bottled water sample that might be either leached from the plastic packaging materials or contamination during bottling processes. Bottled waters stored at 4°C contained higher levels of DMP, DEP, BBP and DEHP than those stored at room temperature and outdoors. On the other hand, the levels of DMP, DEP and BBP were significantly lower in bottled waters stored at room temperature than those outdoor. It seems that temperature and sunlight play a role in the degradation of phthalates within time. The levels of BBP were the highest at 4°C storage (4.592 ± 3.081 µg/l; range: 1.194-21.128 µg/l) and approximately 76% of the bottled waters had BBP above the limit of quantification (LOQ) of 0.994 µg/l. Apart from DEHP (< 6 µg/l), there are not current legislations for other phthalates. Regardless of storage conditions, all our samples did not exceed the maximum established limit of DEHP. Although, the levels of phthalates in tested bottled waters were low, one should not dismiss that these chemicals may cause endocrine disruption through several mechanisms, especially to potentially vulnerable populations such as infants and pregnant women. Saudi Arabia ranks 12 in bottled water consumption (88 L per capita in 2004) among the 71 reported countries. With this high consumption, a quality assurance scheme for residue monitoring in water is quite important. Although, one cannot avoid phthalates contamination in bottled waters due to manufacturing process but at least special care should be taken

  3. Determinants of bottle use amongst economically disadvantaged mothers.

    PubMed

    Shamim, Samina; Jamalvi, S Waseem; Naz, Farah

    2006-01-01

    There is documented evidence of increased risk of infant mortality in formula fed infants versus breast fed babies. The hazards of bottle use for infant feeding, especially in underprivileged communities, are also well known. As the issue of bottle use is directly related to childhood survival and mortality, there is legislation against propagation of bottle-feeding in Pakistan. To obtain information about determinants of bottle use for infant feeding in a low-income periurban community. Community based cross-sectional study. 150 mothers with infants up to one year of age were included in the study period from October 03 to March 04. Out of these 102 mothers were found using bottle for infant with or without breast-feeding. The tendency to use the bottle increased in relation to child's increasing age. Only 17% of the infants under the age of 3 months were offered bottle, it was 69% between 4 to 6 months and it increased to 76% in infants from 7 months to 1 year. The attributes associated with increased bottle use were mother's older age, illiteracy and increased parity. Bottle use is a public health issue in poor and illiterate mothers of developing countries. While, in Pakistan, laws are enacted against its propagation, we need community-based strategies to bring about a socio-cultural shift in the growing prevalence of bottle use found in the study.

  4. Packaging waste prevention activities: A life cycle assessment of the effects on a regional waste management system.

    PubMed

    Nessi, Simone; Rigamonti, Lucia; Grosso, Mario

    2015-09-01

    A life cycle assessment was carried out to evaluate the effects of two packaging waste prevention activities on the overall environmental performance of the integrated municipal waste management system of Lombardia region, Italy. The activities are the use of refined tap water instead of bottled water for household consumption and the substitution of liquid detergents packaged in single-use containers by those distributed 'loose' through self-dispensing systems and refillable containers. A 2020 baseline scenario without waste prevention is compared with different waste prevention scenarios, where the two activities are either separately or contemporaneously implemented, by assuming a complete substitution of the traditional product(s). The results show that, when the prevention activities are carried out effectively, a reduction in total waste generation ranging from 0.14% to 0.66% is achieved, corresponding to a 1-4% reduction of the affected packaging waste fractions (plastics and glass). However, the improvements in the overall environmental performance of the waste management system can be far higher, especially when bottled water is substituted. In this case, a nearly 0.5% reduction of the total waste involves improvements ranging mostly between 5 and 23%. Conversely, for the substitution of single-use packaged liquid detergents (0.14% reduction of the total waste), the achieved improvements do not exceed 3% for nearly all impact categories. © The Author(s) 2015.

  5. Running Mechanics and Metabolic Responses with Water Bottles and Bottle Belt Holders.

    PubMed

    Vincent, Heather K; Zdziarski, Laura A; Fallgatter, Kyle; Negron, Giorgio; Chen, Cong; Leavitt, Trevor; Horodyski, MaryBeth; Wasser, Joseph G; Vincent, Kevin R

    2018-01-18

    This study determined whether differential kinematics, kinetics, rates of energy use and cardiopulmonary responses occurred during running with water bottles and bottle belt holders compared to running only. Trained runners (N=42; 27.2±6.4 yr) ran on an instrumented treadmill for four conditions in a randomized order: 1) control run (CON); 2) hand-held full water bottle (FULL, 16.9 fluid oz; 454 g); 3) hand-held half-full water bottle (HALF, 8.4 fluid oz.; 227 g); and 4) waist-worn bottle belt holder (BELT; hydration belt; 676 g). Gas exchange was measured using a portable gas analyzer. Kinetic and kinematic responses were determined via standard 3D videographic techniques. Interactions of limb side (right, left) by study condition (CON, FULL, HALF, BELT) were tested for rates of oxygen use and energy expenditure, and kinematic and kinetic parameters. No significant limb side × condition interactions existed for rates of oxygen use or energy expenditure. A significant interaction occurred with sagittal elbow flexion (p<0.001). Transverse pelvis rotation excursions differed on average 3.8° across conditions. The minimum sagittal hip flexion moment was higher in the right leg in the HALF and BELT conditions compared to CON (p<0.001). Carriage of water by hand or on the waist does not significantly change kinematics of running motion, rates of oxygen use and energy expenditure or cardiopulmonary measures over short durations. Runners are likely making adjustments to joint moments and powers that preserve balance and protect the lower extremity joints while maintaining the rates of oxygen use and energy expenditure.

  6. Fluoride content of still bottled water in Australia.

    PubMed

    Cochrane, N J; Saranathan, S; Morgan, M V; Dashper, S G

    2006-09-01

    Recently there has been a considerable increase in the consumption of bottled water in Australia. Overseas studies have found the fluoride levels in many bottled waters are well below levels considered optimal for preventing dental caries. This raises the concern that if bottled water is regularly consumed an effective means of preventing dental caries is unavailable. The aim of this study was to determine the fluoride concentration in 10 popular brands of still bottled water currently sold in Australia. The fluoride content of water samples were determined using an ion analyser and compared to a fluoride standard. The fluoride concentration of all bottled waters was less than 0.08 ppm. Only three of the 10 brands indicated the fluoride content on their labels. Melbourne reticulated water was found to be fluoridated at 1.02 ppm. All bottled waters tested contained negligible fluoride which justifies the concern that regular consumption of bottled water may reduce the benefits gained from water fluoridation. It is recommended that all bottled water companies should consider stating their fluoride content on their labels. This will inform consumers and dental care providers of the levels of fluoride in bottled water and allow an informed decision regarding consumption of fluoridated versus non-fluoridated drinking water.

  7. A descriptive study of bottle-feeding opportunities in preterm infants.

    PubMed

    Pickler, Rita H; Reyna, Barbara A

    2003-06-01

    The purposes of this study were to describe patterns of bottle feeding opportunities in preterm infants and to analyze the relationships between feeding opportunities and outcomes. The smaple was composed of 25 preterm infants who were bottle fed. Retrospective, correlational. Data were collected from medical records and analyzed descriptively. Correlation coefficients among variables were computed. Postconceptional age (PCA) at the time of full bottle feedings and transition time from the first to full bottle feedings. The number of bottle feedings received per day during the transition from first to full bottle feedings was inversely related to length of transition to full bottle feedings. There was no relationship between the number of bottle-feeding opportunities and PCA at full bottle feedings. The achievement of full bottle feedings may be facilitated by increased bottle-feeding opportunities. More research about the relationships among feeding readiness, outcomes, and opportunities is needed.

  8. Bottle appeal drifts across the Pacific

    NASA Astrophysics Data System (ADS)

    Ebbesmeyer, Curtis; Ingraham, W. James, Jr.; McKinnon, Richard; Okubo, Akira; Wang, Dong-Ping; Strickland, Richard; Willing, Peter

    Pacific drift currents were used by a group of oceanographers to estimate the path of a drift bottle that was found on a beach of Barkley Sound in Vancouver Island by Richard Strickland on June 10, 1990. The Chinese rice wine bottle, which remained unopened until December 18, 1991, contained six leaflets, one appealing for the release of China's well-known dissident, Wei Jingsheng. The bottle was one of thousands set adrift as part of a propaganda effort from the islands of Quemoy and Matsu off mainland China shortly after Wei was sentenced in 1979 to 15 years in prison (see Figure 1 for locations). Wei was in poor health and still in prison when the bottle made its way across the Pacific Ocean.

  9. 27 CFR 24.256 - Bottle aging wine.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2014-04-01 2014-04-01 false Bottle aging wine. 24.256 Section 24.256 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT... of Wine § 24.256 Bottle aging wine. Wine bottled or packed and stored for the purpose of aging need...

  10. 27 CFR 24.256 - Bottle aging wine.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2011-04-01 2011-04-01 false Bottle aging wine. 24.256 Section 24.256 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT... of Wine § 24.256 Bottle aging wine. Wine bottled or packed and stored for the purpose of aging need...

  11. 27 CFR 24.256 - Bottle aging wine.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2013-04-01 2013-04-01 false Bottle aging wine. 24.256 Section 24.256 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT... of Wine § 24.256 Bottle aging wine. Wine bottled or packed and stored for the purpose of aging need...

  12. 27 CFR 24.256 - Bottle aging wine.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2012-04-01 2012-04-01 false Bottle aging wine. 24.256 Section 24.256 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT... of Wine § 24.256 Bottle aging wine. Wine bottled or packed and stored for the purpose of aging need...

  13. 27 CFR 31.201 - Refilling of liquor bottles.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... Bottles § 31.201 Refilling of liquor bottles. No person who sells, or offers for sale, distilled spirits... or increase any portion of the original contents contained in that bottle at the time of closing...

  14. Application of visible spectroscopy in waste sorting

    NASA Astrophysics Data System (ADS)

    Spiga, Philippe; Bourely, Antoine

    2011-10-01

    Today, waste recycling, (bottles, papers...), is a mechanical operation: the waste are crushed, fused and agglomerated in order to obtain new manufactured products (e.g. new bottles, clothes ...). The plastics recycling is the main application in the color sorting process. The colorless plastics recovered are more valuable than the colored plastics. Other emergent applications are in the paper sorting, where the main goal is to sort dyed paper from white papers. Up to now, Pellenc Selective Technologies has manufactured color sorting machines based on RGB cameras. Three dimensions (red, green and blue) are no longer sufficient to detect low quantities of dye in the considered waste. In order to increase the efficiency of the color detection, a new sorting machine, based on visible spectroscopy, has been developed. This paper presents the principles of the two approaches and their difference in terms of sorting performance, making visible spectroscopy a clear winner.

  15. Observation of practices at petting zoos and the potential impact on zoonotic disease transmission.

    PubMed

    Weese, J Scott; McCarthy, Lisa; Mossop, Michael; Martin, Hayley; Lefebvre, Sandi

    2007-07-01

    Although petting zoos are common at public events and allow the public to interact with animals, there has been minimal evaluation of practices at petting zoos. Unannounced observation was performed at 36 petting zoos in Ontario, Canada. Observers recorded information, including physical layout, animal species, animal health, types of animal contact permitted, animal sources, hand hygiene facilities, signage, sale of food for human consumption, and hand hygiene compliance. The majority of petting zoos (24 [67%] of 36 petting zoos) were part of temporary events, particularly agricultural fairs (21 [58%] of 36 petting zoos). A variety of animal species were present, including some animals that are considered to be at particularly high risk for disease transmission (neonatal calves and baby chicks). The following items that would come into contact with the mouths of infants and children were carried into the petting zoos: baby bottles (at 17 petting zoos; 50%), pacifiers (at 24 petting zoos; 71%), spill-proofs cups (at 19 petting zoos; 56%), and infant toys (at 22 petting zoos; 65%). Hand hygiene facilities were provided at 34 (94%) of 36 events, and hand hygiene compliance ranged from 0% through 77% (mean compliance [+/-SD], 30.9%+/-22.1%; median compliance, 26.5%). Predictors for increased hand hygiene compliance included the location of a hand hygiene station on an exit route, the presence of hand hygiene reminder signs, and the availability of running water. Numerous deficiencies were encountered. Better education of petting zoo operators and the general public is needed. Provision of hand hygiene stations with running water that are placed near exits is one effective way to encourage compliance.

  16. 27 CFR 24.308 - Bottled or packed wine record.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Bottled or packed wine... BUREAU, DEPARTMENT OF THE TREASURY LIQUORS WINE Records and Reports § 24.308 Bottled or packed wine record. A proprietor who bottles, packs, or receives bottled or packed beverage wine in bond shall...

  17. Buying and Caring for Baby Bottles and Nipples

    MedlinePlus

    ... will not break if dropped. If you choose plastic, it is best to buy new bottles. Reused or hand-me-down bottles may contain bisphenol-A (BPA). The Food and Drug Administration (FDA) has banned the use of BPA in baby bottles due to safety ...

  18. Recycling polyethylene terephthalate wastes as short fibers in Strain-Hardening Cementitious Composites (SHCC).

    PubMed

    Lin, Xiuyi; Yu, Jing; Li, Hedong; Lam, Jeffery Y K; Shih, Kaimin; Sham, Ivan M L; Leung, Christopher K Y

    2018-05-26

    As an important portion of the total plastic waste bulk but lack of reuse and recycling, the enormous amounts of polyethylene terephthalate (PET) solid wastes have led to serious environmental issues. This study explores the feasibility of recycling PET solid wastes as short fibers in Strain-Hardening Cementitious Composites (SHCCs), which exhibit strain-hardening and multiple cracking under tension, and therefore have clear advantages over conventional concrete for many construction applications. Based on micromechanical modeling, fiber dispersion and alkali resistance, the size of recycled PET fibers was first determined. Then the hydrophobic PET surface was treated with NaOH solution followed by a silane coupling agent to achieve the dual purpose of improving the fiber/matrix interfacial frictional bond (from 0.64 MPa to 0.80 MPa) and enhancing the alkali resistance for applications in alkaline cementitious environment. With surface treatment, recycling PET wastes as fibers in SHCCs is a promising approach to significantly reduce the material cost of SHCCs while disposing hazardous PET wastes in construction industry. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. 27 CFR 19.749 - Bottling and packaging record.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Bottling and packaging record. 19.749 Section 19.749 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE... Account § 19.749 Bottling and packaging record. The bottling and packaging record shall be prepared and...

  20. Bottle Biology.

    ERIC Educational Resources Information Center

    Jager, Peter

    1993-01-01

    Describes activities which utilize plastic drink bottles and are designed to foster the development of a wide range of biological and ecological concepts. Includes instructions for making a model compost column and presents a model that illustrates open versus closed ecosystems. (DDR)

  1. 27 CFR 31.202 - Possession of refilled liquor bottles.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... Liquor Bottles § 31.202 Possession of refilled liquor bottles. No person who sells, or offers for sale... bottle, any portion of the contents of which has been altered or increased in violation of the provisions...

  2. [India: breast feeding is obsolete, the bottle is modern].

    PubMed

    Uniyal, M

    1992-09-07

    In July, 1992 Indian health groups met in New Delhi to demand that the government promote a child nutrition code based on the 1981 code of the WHO which stated that mother's milk is quite sufficient and is the best nourishment for infants. Every day approximately 40,000 children are born in India, but thousands of them die in infancy because of infection caused by the unsanitary mixing of milk powder in unsterile bottles. Indian health activists want the government to regulate the production, access, and distribution of mother's milk substitutes, bottles, and child nutriments. A new law based on internationally recognized codes for marketing mother's milk substitutes could put an end to the present irresponsible marketing. Activists are not opposed to the production of milk powder, but they think it should only be used when the mother has no milk. The turnover of India's child nutrition industry is about $280 million per year with an annual increase of 5%. The use of bottle feeding has infiltrated the whole urban scene, and it is spreading in rural areas. Women consider bottle feeding a modern way of child feeding. 60 million kg of milk powder is produced yearly and sold under 25 different product names. Amul and Nestle command 85% of the growing market. Experts have calculated that 1 billion liters of mother's milk is wasted and replaced by substitute milk every year. Many Indian children get their first substitute milk at health posts where free or subsidized milk is distributed despite notices calling on mothers to breast-feed. According to a national survey sponsored by UNICEF, almost 1/2 of India's mothers give their children milk substitutes at the instigation of doctors or health personnel. 63% of children in the state of West Bengal were undernourished because families did not buy enough milk powder. The activists want the government to launch an offensive against the advertisement of breast milk substitutes in state-owned TV and radio and to promote proper

  3. 27 CFR 31.232 - Wine bottling.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    .... The decanting of wine by caterers or other retail dealers for table or room service, banquets, and... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Wine bottling. 31.232... OF THE TREASURY LIQUORS ALCOHOL BEVERAGE DEALERS Miscellaneous § 31.232 Wine bottling. Each person...

  4. 21 CFR 165.110 - Bottled water.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ..., when a composite of analytical units of equal volume from a sample is examined by the method described...)(A) Bottled water shall, when a composite of analytical units of equal volume from a sample is..., and Cosmetic Act, the Food and Drug Administration has determined that bottled water, when a composite...

  5. A Novel Water Delivery System for Administering Volatile Chemicals while Minimizing Chemical Waste in Rodent Toxicity Studies

    EPA Science Inventory

    Rodent toxicity studies typically use water bottles to administer test chemicals via drinking water. However, water bottles provide inconsistent exposure of volatile chemicals due to varying headspace, as well as lead to excessive waste of test material. In order to refine drin...

  6. A novel water delivery system for administering volatile chemicals while minimizing chemical waste in rodent toxicity sutdies

    EPA Science Inventory

    Rodent toxicity studies typically use water bottles to administer test chemicals via drinking water. However, water bottles provide inconsistent exposure of volatile chemicals due to varying headspace, as well as lead to excessive waste of test material. In order to refine drinki...

  7. 21 CFR 880.6085 - Hot/cold water bottle.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Hot/cold water bottle. 880.6085 Section 880.6085... Devices § 880.6085 Hot/cold water bottle. (a) Identification. A hot/cold water bottle is a device intended for medical purposes that is in the form of a container intended to be filled with hot or cold water...

  8. 21 CFR 880.6085 - Hot/cold water bottle.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hot/cold water bottle. 880.6085 Section 880.6085... Devices § 880.6085 Hot/cold water bottle. (a) Identification. A hot/cold water bottle is a device intended for medical purposes that is in the form of a container intended to be filled with hot or cold water...

  9. 21 CFR 880.6085 - Hot/cold water bottle.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Hot/cold water bottle. 880.6085 Section 880.6085... Devices § 880.6085 Hot/cold water bottle. (a) Identification. A hot/cold water bottle is a device intended for medical purposes that is in the form of a container intended to be filled with hot or cold water...

  10. 21 CFR 880.6085 - Hot/cold water bottle.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Hot/cold water bottle. 880.6085 Section 880.6085... Devices § 880.6085 Hot/cold water bottle. (a) Identification. A hot/cold water bottle is a device intended for medical purposes that is in the form of a container intended to be filled with hot or cold water...

  11. 21 CFR 880.6085 - Hot/cold water bottle.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Hot/cold water bottle. 880.6085 Section 880.6085... Devices § 880.6085 Hot/cold water bottle. (a) Identification. A hot/cold water bottle is a device intended for medical purposes that is in the form of a container intended to be filled with hot or cold water...

  12. Physical, chemical and microbial analysis of bottled drinking water.

    PubMed

    Sasikaran, S; Sritharan, K; Balakumar, S; Arasaratnam, V

    2012-09-01

    People rely on the quality of the bottled drinking water, expecting it to be free of microbial contamination and health hazards. To evaluate the quality of bottled drinking water sold in Jaffna peninsula by analysing the physical, chemical and microbial contents and comparing with the recommended Sri Lankan Standard (SLS) values. All bottled water samples sold in Jaffna peninsula were collected. Electrical conductivity, total dissolved solid, pH, calcium, nitrate, total aerobic and anaerobic count, coliform bacterial count and faecal contamination were checked. These are 22 brands of bottled drinking water sold in Jaffna peninsula. The sample had very low electrical conductivity when compared with SLS (750 μS/ cm) and varied from 19 to 253 μS/cm with the mean of 80.53 (±60.92) μS/cm. The pH values of the bottled drinking water brands varied from 4.11 to 7.58 with a mean of 6.2 (±0.75). The total dissolved solid content of the bottled drinking water brands varied from 9 to 123.67 mg/l with a mean of 39.5 (±30.23) mg/l. The calcium content of the bottled drinking water brands varied from 6.48 to 83.77 mg/l with a mean of 49.9 (±25.09) mg/l. The nitrate content of the bottled drinking water brands varied from 0.21 to 4.19 mg/l with the mean of 1.26 (±1.08) mg/l. Aerobic bacterial count varied from 0 to 800 colony forming unit per ml (cfu/ml) with a mean of 262.6 (±327.50) cfu/ml. Among the 22 drinking bottled water brands 14 and 9% of bottled drinking water brands showed fungal and coliform bacterial contaminants respectively. The water brands which contained faecal contamination had either Escherichia coli or Klebsiella spp. The bottled drinking water available for sale do not meet the standards stipulated by SLS.

  13. Bottle-feeding legislation in Papua New Guinea.

    PubMed

    Lambert, J

    1980-02-01

    Research in Papua New Guinea and elsewhere in the developing world has indicted the dangers of bottle feeding infants. Following a failure to obtain the voluntary agreement of shopkeepers to restrict sales of infant-feeding bottles and teats, legislation was passed which placed these items on prescription. In order to obtain a prescription certain conditions have to be satisfied. A follow-up survey which was carried out in Port Moresby two years after the introduction of legislation indicated a significant decline in the extent of bottle feeding.

  14. Ergonomics Designs of Aluminum Beverage Cans & Bottles

    NASA Astrophysics Data System (ADS)

    Han, Jing; Itoh, Ryouiti; Yamazaki, Koetsu; Nishiyama, Sadao; Shinguryo, Takuro

    2005-08-01

    This paper introduced the finite element analyses into the ergonomics designs to evaluate the human feelings numerically and objectively. Two design examples in developing aluminum beverage cans & bottles are presented. The first example describes a design of the tab of the can with better finger access. A simulation of finger pulling up the tab of the can has been performed and a pain in the finger has been evaluated by using the maximum value of the contact stress of a finger model. The finger access comparison of three kinds of tab ring shape designs showed that the finger access of the tab that may have a larger contact area with finger is better. The second example describes a design of rib-shape embossed bottles for hot vending. Analyses of tactile sensation of heat have been performed and the amount of heat transmitted from hot bottles to finger was used to present the hot touch feeling. Comparison results showed that the hot touch feeling of rib-shape embossed bottles is better than that of cylindrical bottles, and that the shape of the rib also influenced the hot touch feeling.

  15. Simultaneous determination and assessment of 4-nonylphenol, bisphenol A and triclosan in tap water, bottled water and baby bottles.

    PubMed

    Li, Xu; Ying, Guang-Guo; Su, Hao-Chang; Yang, Xiao-Bing; Wang, Li

    2010-08-01

    This study investigated the levels of 4-nonylphenol (4-NP), bisphenol A (BPA) and triclosan (TCS) in bottled water and tap water in Guangzhou and release of these chemicals from baby bottles using gas chromatography-mass spectrometry with negative chemical ionization. Results show that 4-NP was present in all the bottled water while 17 out of 21 contained BPA and 18 out of 21 contained TCS. Their concentrations in bottled water ranged from 108 to 298 ng/L, 17.6 to 324 ng/L and 0.6 to 9.7 ng/L, respectively. Five of the tap water samples from six drinking water plants were found to contain 4-NP and BPA both in June and December, while TCS was detected in the same five plants only in June. The highest concentrations in tap water for 4-NP, BPA and TCS were 1987, 317 and 14.5ng/L, respectively. Daily intakes of 4-NP, BPA and TCS of adults by drinking 2L of tap water were estimated to be 1410, 148 and 10 ng/day, respectively. BPA was found to be released within 24h from four brands of baby bottles at room temperature (24 degrees C), 40 degrees C and 100 degrees C. Increased temperature led to higher release of BPA from the baby bottles. Estimated daily intakes of 4-NP, BPA and TCS for infants were 705, 1340 and 5 ng/day, respectively, by drinking 1L of tap water from a baby bottle at 40 degrees C. This study showed that the exposure to the three compounds from drinking water is unlikely to pose a health risk. Copyright 2010 Elsevier Ltd. All rights reserved.

  16. Bottled Water Basics

    MedlinePlus

    ... the following measures: Use a point-of-use filter Consider using point-of-use (per- 2 Bottled ... tap sonal use, end-of-tap, under sink) filters that remove particles one micrometer or less in ...

  17. Computer Simulations of Bottle Brushes: From Melts to Soft Networks

    DOE PAGES

    Cao, Zhen; Carrillo, Jan-Michael Y.; Sheiko, Sergei S.; ...

    2015-07-13

    We use a combination of Molecular dynamics simulations and analytical calculations, and study dens bottle-brush systems in a melt and network State. Analysis of our simulation results shows that bottle-brush macromolecules in melt behave as ideal chains with effective Kuhn length b K. Simulations show that the bottle-brush-induced bending rigidity is due to an entropy decrease caused by redistribution of the side chains upon backbone bending. The Kuhn length of the bottle:brushes increases with increasing the side-chain degree of polymerization n sc as b K proportional to n sc 0.46. Moreover, this model of bottle brush macromolecules is extended tomore » describe mechanical properties of bottle brush networks in linear and nonlinear deformation regimes. In the linear deformation regime, the network shear modulus scales with the degree of polymerization of the side chains as G 0 proportional to (n sc + 1) -1 as long as the ratio of the Kuhn length, b K, to the size of the fully extended bottle-brush backbone between cross-links, R-max, is smaller than unity, b K/R max << 1. Bottle-brush networks With b K/R max proportional to 1 demonstrate behavior similar to that of networks Of semiflexible chains with G 0 proportional to n sc -0.5. Finally, in the nonlinear network deformation regime, the deformation-dependent shear modulus is a universal function of the first strain invariant I 1 and bottle-brush backbone deformation ratio beta describing stretching ability of the bottle-brush backbone between cross-links.« less

  18. Bottles to trees: Plastic beverage bottles as an alternative nursery growing container for reforestation in developing countries.

    PubMed

    Khurram, Safiullah; Burney, Owen T; Morrissey, Robert C; Jacobs, Douglass F

    2017-01-01

    Reforestation is needed globally to help restore degraded sites, combat desertification, protect watersheds, and provide forest products. This involves planting forest tree seedlings grown in local nurseries, but technologies to produce quality seedlings are lacking in developing countries. Modern nursery containers used to propagate seedlings have internal-surface barriers (ribs or ridges) or side-slits to prevent root spiraling. These are cost prohibitive or unavailable in developing countries and so polybags (plastic bags) are more commonly used, despite their tendency to produce seedlings with deformed root systems that have less potential to establish on field sites. Discarded plastic bottles, which are readily available worldwide, may be a feasible alternative for seedling propagation. We conducted two experiments to assess the potential of repurposed plastic beverage bottles to grow quality trees: 1) Container Comparison-to evaluate Arizona walnut (Juglans major [Toor.] Heller) and Afghan pine (Pinus eldarica Medw.) seedling root and shoot development in two plastic bottle types compared to modern nursery containers and polybags, and 2) Bottle Modification-to examine the effects of root spiraling prevention techniques (side-slits, internal-ridges, and control) and container opacity (green, black, and clear) on Afghan pine seedling morphological attributes. Nursery growth and first-year seedling field performance were evaluated for both experiments. In experiment one, seedlings of both species had fewer spiraled roots in bottle containers compared to polybags. Arizona walnut had more fibrous root systems in polybags, while Afghan pine root system fibrosity was greatest in bottle containers. First-year field performance of both species was not affected by container type. In experiment two, less spiraled roots occurred in containers with air-slits and interior-ridges compared to the control. The effects of container opacity on seedling morphology were

  19. Bottles to trees: Plastic beverage bottles as an alternative nursery growing container for reforestation in developing countries

    PubMed Central

    Khurram, Safiullah; Burney, Owen T.; Morrissey, Robert C.

    2017-01-01

    Reforestation is needed globally to help restore degraded sites, combat desertification, protect watersheds, and provide forest products. This involves planting forest tree seedlings grown in local nurseries, but technologies to produce quality seedlings are lacking in developing countries. Modern nursery containers used to propagate seedlings have internal-surface barriers (ribs or ridges) or side-slits to prevent root spiraling. These are cost prohibitive or unavailable in developing countries and so polybags (plastic bags) are more commonly used, despite their tendency to produce seedlings with deformed root systems that have less potential to establish on field sites. Discarded plastic bottles, which are readily available worldwide, may be a feasible alternative for seedling propagation. We conducted two experiments to assess the potential of repurposed plastic beverage bottles to grow quality trees: 1) Container Comparison–to evaluate Arizona walnut (Juglans major [Toor.] Heller) and Afghan pine (Pinus eldarica Medw.) seedling root and shoot development in two plastic bottle types compared to modern nursery containers and polybags, and 2) Bottle Modification–to examine the effects of root spiraling prevention techniques (side-slits, internal-ridges, and control) and container opacity (green, black, and clear) on Afghan pine seedling morphological attributes. Nursery growth and first-year seedling field performance were evaluated for both experiments. In experiment one, seedlings of both species had fewer spiraled roots in bottle containers compared to polybags. Arizona walnut had more fibrous root systems in polybags, while Afghan pine root system fibrosity was greatest in bottle containers. First-year field performance of both species was not affected by container type. In experiment two, less spiraled roots occurred in containers with air-slits and interior-ridges compared to the control. The effects of container opacity on seedling morphology were

  20. Mechanics of sucking: comparison between bottle feeding and breastfeeding

    PubMed Central

    2010-01-01

    Background There is very little evidence of the similarity of the mechanics of maternal and bottle feeding. We assessed the mechanics of sucking in exclusive breastfeeding, exclusive bottle feeding, and mixed feeding. The hypothesis established was that physiological pattern for suckling movements differ depending on the type of feeding. According to this hypothesis, babies with breastfeeding have suckling movements at the breast that are different from the movements of suckling a teat of babies fed with bottle. Children with mixed feeding mix both types of suckling movements. Methods Cross-sectional study of infants aged 21-28 days with only maternal feeding or bottle feeding (234 mother-infant pairs), and a randomized open cross-over field trial in newborns aged 21-28 days and babies aged 3-5 months with mixed feeding (125 mother-infant pairs). Primary outcome measures were sucks and pauses. Results Infants aged 21-28 days exclusively bottle-fed showed fewer sucks and the same number of pauses but of longer duration compared to breastfeeding. In mixed feeding, bottle feeding compared to breastfeeding showed the same number of sucks but fewer and shorter pauses, both at 21-28 days and at 3-5 months. The mean number of breastfeedings in a day (in the mixed feed group) was 5.83 ± 1.93 at 21-28 days and 4.42 ± 1.67 at 3-5 months. In the equivalence analysis of the mixed feed group, the 95% confidence interval for bottle feeding/breastfeeding ratio laid outside the range of equivalence, indicating 5.9-8.7% fewer suction movements, and fewer pauses, and shorter duration of them in bottle feeding compared with breastfeeding. Conclusions The mechanics of sucking in mixed feeding lay outside the range of equivalence comparing bottle feeding with breastfeeding, although differences were small. Children with mixed feeding would mix both types of sucking movements (breastfeeding and bottle feeding) during the learning stage and adopt their own pattern. PMID:20149217

  1. EXAMINATION OF BOTTLED WATER FOR NONTUBERCULOUS MYCOBACTERIA

    EPA Science Inventory

    The objective of this study was to examine bottled water for the presence of nontuberculous mycobacteria as a potential source of infection in AIDS patients. Twenty brands of bottled water commonly used in the Los Angeles area were tested for the presence of nontuberculous mycoba...

  2. Gas Property Demonstrations Using Plastic Water Bottles

    ERIC Educational Resources Information Center

    Campbell, Dean J.; Bannon, Stephen J.; Gunter, Molly M.

    2011-01-01

    Plastic water bottles are convenient containers for demonstrations of gas properties illustrating Boyle's law, Charles's law, and Avogadro's law. The contents of iron-based disposable hand warmer packets can be used to remove oxygen gas from the air within an unfilled plastic water bottle.

  3. Beer bottle whistling: a stochastic Hopf bifurcation

    NASA Astrophysics Data System (ADS)

    Boujo, Edouard; Bourquard, Claire; Xiong, Yuan; Noiray, Nicolas

    2017-11-01

    Blowing in a bottle to produce sound is a popular and yet intriguing entertainment. We reproduce experimentally the common observation that the bottle ``whistles'', i.e. produces a distinct tone, for large enough blowing velocity and over a finite interval of blowing angle. For a given set of parameters, the whistling frequency stays constant over time while the acoustic pressure amplitude fluctuates. Transverse oscillations of the shear layer in the bottle's neck are clearly identified with time-resolved particle image velocimetry (PIV) and proper orthogonal decomposition (POD). To account for these observations, we develop an analytical model of linear acoustic oscillator (the air in the bottle) subject to nonlinear stochastic forcing (the turbulent jet impacting the bottle's neck). We derive a stochastic differential equation and, from the associated Fokker-Planck equation and the measured acoustic pressure signals, we identify the model's parameters with an adjoint optimization technique. Results are further validated experimentally, and allow us to explain (i) the occurrence of whistling in terms of linear instability, and (ii) the amplitude of the limit cycle as a competition between linear growth rate, noise intensity, and nonlinear saturation. E. B. and N. N. acknowledge support by Repower and the ETH Zurich Foundation.

  4. Acoustic Emission Test for Aircraft Halon 1301 Fire Extinguisher Bottles

    DOT National Transportation Integrated Search

    1998-04-01

    An acoustic emission test for aircraft Halon 1301 bottles has been developed, a prototype acoustic emission test system constructed, and over 200 used bottles tested at the repair facilities of the two manufacturers of these bottles. The system monit...

  5. ARRAYS OF BOTTLES OF PLUTONIUM NITRATE SOLUTION

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Margaret A. Marshall

    2012-09-01

    In October and November of 1981 thirteen approaches-to-critical were performed on a remote split table machine (RSTM) in the Critical Mass Laboratory of Pacific Northwest Laboratory (PNL) in Richland, Washington using planar arrays of polyethylene bottles filled with plutonium (Pu) nitrate solution. Arrays of up to sixteen bottles were used to measure the critical number of bottles and critical array spacing with a tight fitting Plexiglas® reflector on all sides of the arrays except the top. Some experiments used Plexiglas shells fitted around each bottles to determine the effect of moderation on criticality. Each bottle contained approximately 2.4 L ofmore » Pu(NO3)4 solution with a Pu content of 105 g Pu/L and a free acid molarity H+ of 5.1. The plutonium was of low 240Pu (2.9 wt.%) content. These experiments were sponsored by Rockwell Hanford Operations because of the lack of experimental data on the criticality of arrays of bottles of Pu solution such as might be found in storage and handling at the Purex Facility at Hanford. The results of these experiments were used “to provide benchmark data to validate calculational codes used in criticality safety assessments of [the] plant configurations” (Ref. 1). Data for this evaluation were collected from the published report (Ref. 1), the approach to critical logbook, the experimenter’s logbook, and communication with the primary experimenter, B. Michael Durst. Of the 13 experiments preformed 10 were evaluated. One of the experiments was not evaluated because it had been thrown out by the experimenter, one was not evaluated because it was a repeat of another experiment and the third was not evaluated because it reported the critical number of bottles as being greater than 25. Seven of the thirteen evaluated experiments were determined to be acceptable benchmark experiments. A similar experiment using uranyl nitrate was benchmarked as U233-SOL-THERM-014.« less

  6. 27 CFR 19.599 - Bottling and packaging records.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... spirits bottled or packaged (if different from the proof recorded under paragraph (f) of this section); (k) Total quantity bottled, packaged, or otherwise disposed of in bulk; (l) Losses or gains of the distilled...

  7. 27 CFR 19.599 - Bottling and packaging records.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... spirits bottled or packaged (if different from the proof recorded under paragraph (f) of this section); (k) Total quantity bottled, packaged, or otherwise disposed of in bulk; (l) Losses or gains of the distilled...

  8. 27 CFR 19.599 - Bottling and packaging records.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... spirits bottled or packaged (if different from the proof recorded under paragraph (f) of this section); (k) Total quantity bottled, packaged, or otherwise disposed of in bulk; (l) Losses or gains of the distilled...

  9. 27 CFR 26.314 - Distinctive liquor bottles.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2012-04-01 2012-04-01 false Distinctive liquor bottles. 26.314 Section 26.314 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU..., including a photograph of the distinctive liquor bottle, to Customs officials at each affected port of entry...

  10. 27 CFR 26.314 - Distinctive liquor bottles.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2011-04-01 2011-04-01 false Distinctive liquor bottles. 26.314 Section 26.314 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU..., including a photograph of the distinctive liquor bottle, to Customs officials at each affected port of entry...

  11. 27 CFR 19.599 - Bottling and packaging records.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... proof recorded under paragraph (f) of this section); (k) Total quantity bottled, packaged, or otherwise disposed of in bulk; (l) Losses or gains of the distilled spirits product; and (m) If labeled as bottled in...

  12. Effectiveness of waste prevention program in primary students' schools.

    PubMed

    Zorpas, Antonis A; Voukkali, Irene; Loizia, Pantelitsa

    2017-06-01

    Even though reducing waste is at the top of the waste hierarchy, no real decoupling between waste generation and consumption has been demonstrated. Several waste directives had been published from EU, but they have only brought minor changes within the key objective of reducing waste generation. Most efforts have been targeted towards greater amounts of recycling and better management of waste disposal. While these are necessary and socially beneficial goals, they are not adequate for the achievement of long-term sustainability goals. The purpose of this study is to understand students' knowledge, attitudes and behavioural changes in relation to the water plastic bottle of 500 ml. Understanding waste prevention behaviour (WPB) could enable schools' principals, local authorities and committees as well as decision makers to design and implement more effective policies for reducing the amount of specific waste streams that is generated. Students in a daily base bring their own water containers of 500 ml or buy water from the school as they do not feel safe to use other sources of water. Nine hundred ninety-eight refilling stainless steel water refilling bottles (SSWRB-of 600 ml) were shared to the students in four primary schools. The results indicated that the students are presented with different behaviours from class to class for many reasons; most of them are related with what their parents believe, and how themselves or the synergies between them reacts and affected.

  13. Recycled-PET fibre based panels for building thermal insulation: environmental impact and improvement potential assessment for a greener production.

    PubMed

    Ingrao, Carlo; Lo Giudice, Agata; Tricase, Caterina; Rana, Roberto; Mbohwa, Charles; Siracusa, Valentina

    2014-09-15

    A screening of Life Cycle Assessment for the evaluation of the damage arising from the production of 1 kg of recycled Polyethylene Terephthalate (RPET) fibre-based panel for building heat insulation was carried out according to the ISO 14040:2006 and 14044:2006. All data used were collected on site based on observations during site visits, review of documents and interviews with technical personnel and management. These data were processed by using SimaPro 7.3.3, accessing the Ecoinvent v.2.2 database and using the Impact 2002+ method. The study showed damage to be equal to 0.000299 points mostly due to the: 1) PET thermo-bonding fibre supply from China by means of a freight-equipped intercontinental aircraft; 2) production of bottle-grade granulate PET; 3) medium voltage electricity consumption during the manufacturing of RPET fibre panel. It was also highlighted that there were environmental benefits due to recycling through mainly avoiding significant emissions and reduced resource consumption. An improvement assessment was carried out to find solutions aimed at reducing the damage coming from the most impacting phases. Furthermore, the environmental impacts due to the production of the analysed RPET fibre-based panel were compared to other materials with the same insulating function, such as polystyrene foam, rock wool and cork slab. Finally, the environmental benefits of the recycling of PET bottles for flake production were highlighted compared to other treatment scenarios such as landfill and municipal incineration. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. From Comb-like Polymers to Bottle-Brushes

    NASA Astrophysics Data System (ADS)

    Liang, Heyi; Cao, Zhen; Dobrynin, Andrey; Sheiko, Sergei

    We use a combination of the coarse-grained molecular dynamics simulations and scaling analysis to study conformations of bottle-brushes and comb-like polymers in a melt. Our analysis show that bottle-brushes and comb-like polymers can be in four different conformation regimes depending on the number of monomers between grafted side chains and side chain degree of polymerization. In loosely-grafted comb regime (LC) the degree of polymerization between side chains is longer than side chain degree of polymerization, such that the side chains belonging to the same macromolecule do not overlap. Crossover to a new densely-grafted comb regime (DC) takes place when side chains begin to overlap reducing interpenetration of side chains belonging to different macromolecules. In these two regimes both side-chains and backbone behave as unperturbed linear chains with the effective Kuhn length of the backbone being close to that of linear chain. Further decrease spacer degree of polymerization results in crossover to loosely-grafted bottle-brush regime (LB). In this regime, the bottle-brush backbone is stretched while the side-chains still maintain ideal chain conformation. Finally, for even shorter spacer between grafted side chains, which corresponds to densely-grafted bottle-brush regime (DB), the backbone adopts a fully extended chain conformation, and side-chains begin to stretch to maintain a constant monomer density. NSF DMR-1409710, DMR-1407645, DMR-1624569, DMR-1436201.

  15. Recycling potential of post-consumer plastic packaging waste in Finland.

    PubMed

    Dahlbo, Helena; Poliakova, Valeria; Mylläri, Ville; Sahimaa, Olli; Anderson, Reetta

    2018-01-01

    Recycling of plastics is urged by the need for closing material loops to maintain our natural resources when striving towards circular economy, but also by the concern raced by observations of plastic scrap in oceans and lakes. Packaging industry is the sector using the largest share of plastics, hence packaging dominates in the plastic waste flow. The aim of this paper was to sum up the recycling potential of post-consumer plastic packaging waste in Finland. This potential was evaluated based on the quantity, composition and mechanical quality of the plastic packaging waste generated by consumers and collected as a source-separated fraction, within the mixed municipal solid waste (MSW) or within energy waste. Based on the assessment 86,000-117,000 tons (18 kg/person/a) of post-consumer plastic packaging waste was generated in Finland in 2014. The majority, 84% of the waste was in the mixed MSW flow in 2014. Due to the launching of new sorting facilities and separate collections for post-consumer plastic packaging in 2016, almost 40% of the post-consumer plastic packaging could become available for recycling. However, a 50% recycling rate for post-consumer plastic packaging (other than PET bottles) would be needed to increase the overall MSW recycling rate from the current 41% by around two percentage points. The share of monotype plastics in the overall MSW plastics fraction was 80%, hence by volume the recycling potential of MSW plastics is high. Polypropylene (PP) and low density polyethylene (LDPE) were the most common plastic types present in mixed MSW, followed by polyethylene terephthalate (PET), polystyrene (PS) and high density polyethylene (HDPE). If all the Finnish plastic packaging waste collected through the three collection types would be available for recycling, then 19,000-25,000 tons of recycled PP and 6000-8000 tons of recycled HDPE would be available on the local market. However, this assessment includes uncertainties due to performing the

  16. Detection of bottled liquid explosives by near infrared

    NASA Astrophysics Data System (ADS)

    Itozaki, Hide; Miyamura, Ryu; Sato-Akaba, Hideo

    2012-10-01

    Bottled liquids are limited to be brought in the airplane, because liquid explosives have been used in some terrorist attaches recently. A bottled liquid scanner is expected to be developed. Liquid scanner using near infrared technologies is being developed by us. Many spectrum of liquids have been collected and analyzed by chemometorics in order to separate safe beverage to explosive and dangerous liquids. This bottled liquid scanner had feasibility tests in some international airport in Japan and obtained good review from security people in the airport.

  17. 27 CFR 19.402 - Inventories of bottled and packaged spirits.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... Than Denaturation and Manufacture of Articles Inventories § 19.402 Inventories of bottled and packaged spirits. (a) Physical inventories. (1) Physical inventories of bottled and packaged spirits in the... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Inventories of bottled and...

  18. Ergonomics Designs of Aluminum Beverage Cans and Bottles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Han Jing; Itoh, Ryouiti; Shinguryo, Takuro

    2005-08-05

    This paper introduced the finite element analyses into the ergonomics designs to evaluate the human feelings numerically and objectively. Two design examples in developing aluminum beverage cans and bottles are presented. The first example describes a design of the tab of the can with better finger access. A simulation of finger pulling up the tab of the can has been performed and a pain in the finger has been evaluated by using the maximum value of the contact stress of a finger model. The finger access comparison of three kinds of tab ring shape designs showed that the finger accessmore » of the tab that may have a larger contact area with finger is better. The second example describes a design of rib-shape embossed bottles for hot vending. Analyses of tactile sensation of heat have been performed and the amount of heat transmitted from hot bottles to finger was used to present the hot touch feeling. Comparison results showed that the hot touch feeling of rib-shape embossed bottles is better than that of cylindrical bottles, and that the shape of the rib also influenced the hot touch feeling.« less

  19. [Nationwide survey on radioactive waste management related to positron emission tomography in Japan].

    PubMed

    Nagaoka, Hiroaki; Watanabe, Hiroshi; Yamaguchi, Ichiro; Fujibuchi, Toshioh; Kida, Tetsuo; Tanaka, Shinji

    2009-12-20

    A clearance system for medical radioactive solid waste has not yet been implemented in Japan. Since 2004 new regulations have allowed institutions using positron emission tomography(PET)to handle totally decayed radioactive waste as non-radioactive waste after decay-in-storage. It was expected that this new regulation would mediate the installation of clearance systems in Japan. In order to assess the current situation of radiation safety management in PET institutions, we conducted a nationwide survey. The study design was a cross-sectional descriptive study conducted by questionnaire. The subjects of this survey were all the PET institutions in Japan. Among 224 institutes, 128 institutes are equipped with cyclotrons and 96 institutes are not. The number of returned questionnaires was 138. Among institutes that are using delivered radiopharmaceuticals, 80% treat their waste as non-radioactive according to the new regulation. The impact of new regulations for reducing radioactive waste in PET institutes without a cyclotron was estimated at about $400 thousand per year. The main concern of medical institutes was assessment of the contamination caused by by-products of radioactive nuclides generated in target water during the operation of a cyclotron. It was thought that a rational rule based on scientific risk management should be established because these by-products of radioactive nuclides are negligible for radiation safety. New regulation has had a good influence on medical PET institutes, and it is expected that a clearance system for medical radioactive waste will be introduced in the near future, following these recent experiences in PET institutes.

  20. Risk perceptions of arsenic in tap water and consumption of bottled water

    NASA Astrophysics Data System (ADS)

    Jakus, Paul M.; Shaw, W. Douglass; Nguyen, To N.; Walker, Mark

    2009-05-01

    The demand for bottled water has increased rapidly over the past decade, but bottled water is extremely costly compared to tap water. The convenience of bottled water surely matters to consumers, but are others factors at work? This manuscript examines whether purchases of bottled water are associated with the perceived risk of tap water. All of the past studies on bottled water consumption have used simple scale measures of perceived risk that do not correspond to risk measures used by risk analysts. We elicit a probability-based measure of risk and find that as perceived risks rise, expenditures for bottled water rise.

  1. Determinants of using pacifier and bottle feeding

    PubMed Central

    Buccini, Gabriela dos Santos; Benício, Maria Helena D’Aquino; Venancio, Sonia Isoyama

    2014-01-01

    OBJECTIVE To analyze the factors associated with the use of pacifiers and/or bottle feeding in infants aged under one year. METHODS This is a cross-sectional study with 34,366 children and using data from the database of the 2nd Nationwide Survey of Breastfeeding Prevalence performed in the Brazilian capitals and Federal District in 2008. Cluster sampling was used. The questionnaire included questions about the use of artificial nipples in the last 24 hours. The analysis considered three outcomes: exclusive use of pacifier, exclusive use of bottle feeding, and use of artificial nipples (pacifier and bottle feeding). Prevalence ratios were obtained using Poisson regression with robust variance following a hierarchical model. RESULTS The following factors were associated with exclusive use of the pacifier: mother working outside the home, primiparity, child was not breastfed within the first hour, and child had consumed tea on the first day at home. The following factors were associated with exclusive use of bottle feeding: mother working outside the home, primiparity, low birth weight, child not breastfed within the first hour, and child had consumed milk formula and tea on the first day at home. The following factors were associated with use of artificial nipples (pacifier and bottle feeding): mother working outside the home, primiparity, cesarean delivery, the male gender, low birth weight, born in a hospital not accredited as “baby friendly”, required health baby monitoring in the Primary Health Care Unit (PR = 0.91), and child had consumed milk formula, water, or tea on the first day at home. CONCLUSIONS This study identified profiles of exclusive users of pacifiers, bottle feeding, and both. The provided information can guide preventive practices for child health. PMID:25210816

  2. How dirty are your reusable water bottles?

    NASA Astrophysics Data System (ADS)

    Williams, S.

    2017-12-01

    Reusable water bottles are an environment-friendly option but may grow harmful bacteria if not washed regularly. To test whether washing habits affect bacterial growth, I swabbed 10 different plastic reusable bottles and counted colony growth after laboratory incubation. My results did not show a clear relationship between days since last wash and colony growth.

  3. Wine bottle colour and oxidative spoilage: whole bottle light exposure experiments under controlled and uncontrolled temperature conditions.

    PubMed

    Dias, Daniel A; Clark, Andrew C; Smith, Trevor A; Ghiggino, Kenneth P; Scollary, Geoffrey R

    2013-06-15

    Exposure of a Chardonnay wine to light from a mercury vapour lamp under controlled temperature conditions showed that colour enhancement was dependent on bottle colour. The increase in colouration was Antique Greenbottle type. Xanthylium pigments were identified as one component contributing to the observed enhancement of colour. The presence of oxygen was shown to be a critical factor to initiate the formation of these xanthylium pigments during light exposure. Without temperature control, wine colour development was highest in Antique Green and lowest in Flint. This alternate order reflects the ability of the darker bottles to retain heat longer than lighter coloured ones as confirmed by surface temperature decay rates. Specific pigments contributing to the wine colour enhancement in uncontrolled temperature/light exposure experiments could not be identified, although tentative evidence was obtained for the presence of flavan-3-ol based compounds. The different bottle glass surfaces did not influence the rate of loss of dissolved oxygen or oxidation of ascorbic acid. The potential to develop the results obtained in this study to identify markers for light and/or temperature exposure of white wines is discussed. Copyright © 2012 Elsevier Ltd. All rights reserved.

  4. 27 CFR 25.157 - Determination of tax on bottled beer.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... bottled beer. 25.157 Section 25.157 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY LIQUORS BEER Tax on Beer Determination of Tax § 25.157 Determination of tax on bottled beer. The quantities of bottled beer removed subject to tax shall be computed to...

  5. 27 CFR 25.157 - Determination of tax on bottled beer.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... bottled beer. 25.157 Section 25.157 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY ALCOHOL BEER Tax on Beer Determination of Tax § 25.157 Determination of tax on bottled beer. The quantities of bottled beer removed subject to tax shall be computed to...

  6. 27 CFR 25.157 - Determination of tax on bottled beer.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... bottled beer. 25.157 Section 25.157 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY ALCOHOL BEER Tax on Beer Determination of Tax § 25.157 Determination of tax on bottled beer. The quantities of bottled beer removed subject to tax shall be computed to...

  7. 27 CFR 25.157 - Determination of tax on bottled beer.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... bottled beer. 25.157 Section 25.157 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY LIQUORS BEER Tax on Beer Determination of Tax § 25.157 Determination of tax on bottled beer. The quantities of bottled beer removed subject to tax shall be computed to...

  8. 27 CFR 25.157 - Determination of tax on bottled beer.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... bottled beer. 25.157 Section 25.157 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY LIQUORS BEER Tax on Beer Determination of Tax § 25.157 Determination of tax on bottled beer. The quantities of bottled beer removed subject to tax shall be computed to...

  9. Scanning electron microscopic study of a Ciloxan bottle blocked by ciprofloxacin crystals.

    PubMed

    John, T

    2001-12-01

    To report blockage of a commercially available ciprofloxacin bottle by white crystalline deposits. This study evaluated the ultrastructural features of the ciprofloxacin crystals. A patient underwent intensive topical treatment of an infectious corneal ulcer with commercially available ciprofloxacin 0.3% ophthalmic solution. During treatment, the patient was unable to obtain medication from the ciprofloxacin bottle and required a new prescription. Examination of the bottle revealed that about 50% of the medication remained, but compression of the bottle with any amount of force failed to deliver any medication. On closer examination, a white material partially filled the nozzle track of the bottle and was on the outer bottle near the nozzle and the inner surface of the bottle cap. These white crystalline deposits were evaluated by scanning electron microscopy. Plate-like, needle, cable and spaghetti-like crystals were found. The needle crystals formed multiple petaloid patterns. This is the first report of blockage of a commercially available ciprofloxacin 0.3% bottle by ciprofloxacin crystals and the inability to deliver medication from the bottle. Ultrastructural study of the white crystalline deposits revealed four types of ciprofloxacin crystals.

  10. Polycarbonate Bottle Use and Urinary Bisphenol A Concentrations

    PubMed Central

    Carwile, Jenny L.; Luu, Henry T.; Bassett, Laura S.; Driscoll, Daniel A.; Yuan, Caterina; Chang, Jennifer Y.; Ye, Xiaoyun; Calafat, Antonia M.; Michels, Karin B.

    2009-01-01

    Background Bisphenol A (BPA) is a high-production-volume chemical commonly used in the manufacture of polycarbonate plastic. Low-level concentrations of BPA in animals and possibly in humans may cause endocrine disruption. Whether ingestion of food or beverages from polycarbonate containers increases BPA concentrations in humans has not been studied. Objectives We examined the association between use of polycarbonate beverage containers and urinary BPA concentrations in humans. Methods We conducted a nonrandomized intervention of 77 Harvard College students to compare urinary BPA concentrations collected after a washout phase of 1 week to those taken after an intervention week during which most cold beverages were consumed from polycarbonate drinking bottles. Paired t-tests were used to assess the difference in urinary BPA concentrations before and after polycarbonate bottle use. Results The geometric mean urinary BPA concentration at the end of the washout phase was 1.2 μg/g creatinine, increasing to 2.0 μg/g creatinine after 1 week of polycarbonate bottle use. Urinary BPA concentrations increased by 69% after use of polycarbonate bottles (p < 0.0001). The association was stronger among participants who reported ≥ 90% compliance (77% increase; p < 0.0001) than among those reporting < 90% compliance (55% increase; p = 0.03), but this difference was not statistically significant (p = 0.54). Conclusions One week of polycarbonate bottle use increased urinary BPA concentrations by two-thirds. Regular consumption of cold beverages from polycarbonate bottles is associated with a substantial increase in urinary BPA concentrations irrespective of exposure to BPA from other sources. PMID:19750099

  11. 49 CFR 192.175 - Pipe-type and bottle-type holders.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false Pipe-type and bottle-type holders. 192.175 Section....175 Pipe-type and bottle-type holders. (a) Each pipe-type and bottle-type holder must be designed so... equipment, that might cause corrosion or interfere with the safe operation of the holder. (b) Each pipe-type...

  12. 49 CFR 192.175 - Pipe-type and bottle-type holders.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Pipe-type and bottle-type holders. 192.175 Section....175 Pipe-type and bottle-type holders. (a) Each pipe-type and bottle-type holder must be designed so... equipment, that might cause corrosion or interfere with the safe operation of the holder. (b) Each pipe-type...

  13. What about the Bottle? Answers to Common Questions.

    ERIC Educational Resources Information Center

    Laird, Valerie

    2001-01-01

    Acknowledges the large amount of confusing information about bottle feeding in areas including nutrition, sanitation, dental health, psychology, and child development. Answers specific questions pertaining to choice of formula and formula preparation, supporting breastfeeding, bottle choice, solid food introduction, feeding position, spitting up,…

  14. An axisymmetric PFEM formulation for bottle forming simulation

    NASA Astrophysics Data System (ADS)

    Ryzhakov, Pavel B.

    2017-01-01

    A numerical model for bottle forming simulation is proposed. It is based upon the Particle Finite Element Method (PFEM) and is developed for the simulation of bottles characterized by rotational symmetry. The PFEM strategy is adapted to suit the problem of interest. Axisymmetric version of the formulation is developed and a modified contact algorithm is applied. This results in a method characterized by excellent computational efficiency and volume conservation characteristics. The model is validated. An example modelling the final blow process is solved. Bottle wall thickness is estimated and the mass conservation of the method is analysed.

  15. On sampling biases arising from insufficient bottle flushing

    NASA Astrophysics Data System (ADS)

    Codispoti, L. A.; Paver, C. R.

    2016-02-01

    Collection of representative water samples using carousel bottles is important for accurately determining biological and chemical gradients. The development of more technologically advanced instrumentation and sampling apparatus causes sampling packages to increase and "soak times" to decrease, increasing the probability that insufficient bottle flushing will produce biased results. Qualitative evidence from various expeditions suggest that insufficient flushing may be a problem. Here we report on multiple field experiments that were conducted to better quantify the errors that can arise from insufficient bottle flushing. Our experiments suggest that soak times of more than 2 minutes are sometimes required to collect a representative sample.

  16. Physicochemical properties of some bottled water brands in Alexandria Governorate, Egypt.

    PubMed

    Ibrahim, Hesham Z; Mohammed, Heba A G; Hafez, Afaf M

    2014-08-01

    Many people use bottled water instead of tap water for many reasons such as taste, ease of carrying, and thinking that it is safer than tap water. Irrespective of the reason, bottled water consumption has been steadily growing in the world for the past 30 years. In Egypt, this is still increasing to reach 3.8 l/person/day, despite its high price compared with tap water. The purpose of this study was to evaluate the physicochemical quality of some bottled water brands and to compare the quality with that reported on manufacture's labeling, Egyptian, and International standards. Fourteen bottled water brands were selected from the local markets of Alexandria city. Three bottles from each brand were randomly sampled, making a total sample size of 42 bottles. Sampling occurred between July 2012 and September 2012. Each bottle was analyzed for its physicochemical parameter and the average was calculated for each brand. The results obtained were compared with the Egyptian standard for bottled water, Food and Drug Administration (FDA), and with bottled water labels. In all bottles in the study, pH values ranged between 7.21 and 8.23, conductivity ranged between 195 and 675 μs/cm, and total dissolved solids, sulfate, chloride, and fluoride were within the range specified by the FDA. Calcium concentrations ranged between 2.7373 and 29.2183 mg/l, magnesium concentrations ranged between 5.7886 and 17.6633 mg/l, sodium between 14.5 and 205.8 mg/l, and potassium between 6.5 and 29.8 mg/l. For heavy metals such as iron, zinc, copper, and manganese, all of them were in conformity with the Egyptian standards and FDA, but nickel concentration in 11 brands was higher than the Egyptian standards. Twelve brands were higher than the Egyptian standards in cadmium concentration, but on comparison with FDA there were only five brands exceeding limits. Lead concentrations were out of range for all brands. On comparison with the labeled values, the quality of bottled water was not

  17. Infant feeding bottle design, growth and behaviour: results from a randomised trial

    PubMed Central

    2012-01-01

    Background Whether the design of an anti-vacuum infant feeding bottle influences infant milk intake, growth or behavior is unknown, and was the subject of this randomized trial. Methods Subjects 63 (36 male) healthy, exclusively formula-fed term infants. Intervention Randomisation to use Bottle A (n = 31), one-way air valve: Philips Avent) versus Bottle B (n = 32), internal venting system: Dr Browns). 74 breast-fed reference infants were recruited, with randomisation (n = 24) to bottle A (n = 11) or B (n = 13) if bottle-feeding was subsequently introduced. Randomisation stratified by gender and parity; computer-based telephone randomisation by independent clinical trials unit. Setting Infant home. Primary outcome measure infant weight gain to 4 weeks. Secondary outcomes (i) milk intake (ii) infant behaviour measured at 2 weeks (validated 3-day diary); (iii) risk of infection; (iv) continuation of breastfeeding following introduction of mixed feeding. Results Number analysed for primary outcome Bottle A n = 29, Bottle B n = 25. Primary outcome There was no significant difference in weight gain between randomised groups (0-4 weeks Bottle A 0.74 (SD 1.2) SDS versus bottle B 0.51 (0.39), mean difference 0.23 (95% CI -0.31 to 0.77). Secondary outcomes Infants using bottle A had significantly less reported fussing (mean 46 versus 74 minutes/day, p < 0.05) than those using bottle B. There was no significant difference in any other outcome measure. Breast-fed reference group There were no significant differences in primary or secondary outcomes between breast-fed and formula fed infants. The likelyhood of breastfeeding at 3 months was not significantly different in infants subsequently randomised to bottle A or B. Conclusion Bottle design may have short-term effects on infant behaviour which merit further investigation. No significant effects were seen on milk intake or growth; confidence in these findings is limited by the small sample size and this needs confirmation in

  18. Impact of oxygen dissolved at bottling and transmitted through closures on the composition and sensory properties of a Sauvignon Blanc wine during bottle storage.

    PubMed

    Lopes, Paulo; Silva, Maria A; Pons, Alexandre; Tominaga, Takatoshi; Lavigne, Valérie; Saucier, Cédric; Darriet, Philippe; Teissedre, Pierre-Louis; Dubourdieu, Denis

    2009-11-11

    This work outlines the results from an investigation to determine the effect of the oxygen dissolved at bottling and the specific oxygen barrier properties of commercially available closures on the composition, color and sensory properties of a Bordeaux Sauvignon Blanc wine during two years of storage. The importance of oxygen for wine development after bottling was also assessed using an airtight bottle ampule. Wines were assessed for the antioxidants (SO(2) and ascorbic acid), varietal thiols (4-mercapto-4-methylpentan-2-one, 3-mercaptohexan-1-ol), hydrogen sulfide and sotolon content, and color throughout 24 months of storage. In addition, the aroma and palate properties of wines were also assessed. The combination of oxygen dissolved at bottling and the oxygen transferred through closures has a significant effect on Sauvignon Blanc development after bottling. Wines highly exposed to oxygen at bottling and those sealed with a synthetic, Nomacorc classic closure, highly permeable to oxygen, were relatively oxidized in aroma, brown in color, and low in antioxidants and volatile compounds compared to wines sealed with other closures. Conversely, wines sealed under more airtight conditions, bottle ampule and screw cap Saran-tin, have the slowest rate of browning, and displayed the greatest contents of antioxidants and varietal thiols, but also high levels of H(2)S, which were responsible for the reduced dominating character found in these wines, while wines sealed with cork stoppers and screw cap Saranex presented negligible reduced and oxidized characters.

  19. Catalytic Pyrolysis of Waste Plastic Mixture

    NASA Astrophysics Data System (ADS)

    Sembiring, Ferdianta; Wahyu Purnomo, Chandra; Purwono, Suryo

    2018-03-01

    Inorganic waste especially plastics still become a major problem in many places. Low biodegradability of this materials causes the effort in recycling become very difficult. Most of the municipal solid waste (MSW) recycling facilities in developing country only use composting method to recover the organic fraction of the waste, while the inorganic fraction is still untreated. By pyrolysis, plastic waste can be treated to produce liquid fuels, flammable gas and chars. Reduction in volume and utilization of the liquid and gas as fuel are the major benefits of the process. By heat integration actually this process can become a self-sufficient system in terms of energy demand. However, the drawback of this process is usually due to the diverse type of plastic in the MSW creating low grade of liquid fuel and harmful gases. In this study, the mixture of plastics i.e. polypropylene (PP) and polyethylene terephthalate (PET) is treated using pyrolysis with catalyst in several operating temperature. PET is problematic to be treated using pyrolysis due to wax-like byproduct in liquid which may cause pipe clogging. The catalyst is the mixture of natural zeolite and bentonite which is able to handle PP and PET mixture feed to produce high grade liquid fuels in terms of calorific value and other fuel properties.

  20. The synthesis of nanostructured SiC from waste plastics and silicon powder

    NASA Astrophysics Data System (ADS)

    Ju, Zhicheng; Xu, Liqiang; Pang, Qiaolian; Xing, Zheng; Ma, Xiaojian; Qian, Yitai

    2009-09-01

    Waste plastics constitute a growing environmental problem. Therefore, the treatment of waste plastics should be considered. Here we synthesize 3C-SiC nanomaterials coexisting with amorphous graphite particles utilizing waste plastics and Si powder at 350-500 °C in a stainless steel autoclave. 3C-SiC could be finally obtained after refluxing with aqueous HClO4 (70 wt%) at 180 °C. X-ray powder diffraction patterns indicate that the product is 3C-SiC with the calculated lattice constant a = 4.36 Å. Transmission electron microscopy (TEM) images show that the SiC samples presented two morphologies: hexagonal platelets prepared by the waste detergent bottles or beverage bottles and nanowires prepared by waste plastic bags respectively. The corresponding selected area electron diffraction (SAED) pattern indicates that either the entire hexagonal platelet or the nanowire is single crystalline. High-resolution TEM shows the planar surfaces of the SiC platelet correspond to {111} planes; the lateral surfaces are {110} planes and the preferential growth direction of the nanowires is along [111]. The output of SiC was ~39% based on the amount of Si powder.

  1. Fluoride Content of Bottled Drinking Waters in Qatar.

    PubMed

    Almulla, Hessa Ibrahim; King, Nigel M; Alnsour, Hamza Mohammad; Sajnani, Anand K

    2016-12-01

    Fluoridation of drinking water has been recognized as one of the most effective ways of achieving community-wide exposure to the caries prevention effects of fluoride (F). A vast majority of people in Qatar use bottled water for drinking. Use of bottled water without knowing the F level may expose children to dental caries risk if the F level is lower than optimal or to dental fluorosis if the F level is too high. The aim of this study was to determine the F concentration of bottled water available in Qatar. A total of 32 brands of bottled water were evaluated. The F concentrations displayed on the labels were recorded. The F ion-selective electrode method was used to measure the F concentration in water samples, and three measurements were taken for every sample to ensure reproducibility. The p value was set at 0.05. The F concentration ranged from 0.06 to 3.0 ppm with a mean value of 0.8 ppm (±0.88). The F levels were provided by the manufacturers on the labels of 60 % of the samples, but this was significantly lower than the measured F levels (p < 0.0001). Moreover, bottled water that was produced in Saudi Arabia had significantly higher levels of F when compared to those produced in other countries (p < 0.05). There was a wide variation in the F levels in the different brands of bottled water. Furthermore, there was a significant disparity between the F levels which were measured and those that were provided on the labels.

  2. The switch to refillable bottled water in Indonesia: a serious health risk.

    PubMed

    Komarulzaman, Ahmad; de Jong, Eelke; Smits, Jeroen

    2017-10-01

    In recent years, the consumption of refillable bottled water has increased considerably in emerging countries. However, the quality of this water is often questionable, as authorities lack the capacity to properly check refilling depots. Given that refillable bottled water not only replaces unimproved water sources, but also better-quality sources, like piped and branded bottled water, its increasing use poses a major health risk. We investigate the motives behind the decision to switch to refillable bottled water in Indonesia. Findings indicate that this switch is driven by lifestyle motives, as well as by cost and availability considerations. It is mostly the young affluent households who switch from piped and 'other' sources to refillable bottled water. In rural areas, the tendency to make this switch is negatively affected by availability problems and the higher price of refillable bottled water. Availability and cost also influence the switch from branded bottled to refillable bottled water, but here it is the poorer households who have a higher propensity to switch. Further exploration of the lifestyle motive and affordability issues, as well as better monitoring of the refilling depots, are needed to improve the quality of drinking water in Indonesia and other emerging countries.

  3. Detection of bottled explosives by near infrared

    NASA Astrophysics Data System (ADS)

    Itozaki, Hideo; Sato-Akaba, Hideo

    2013-10-01

    Bottled liquids are not allowed through the security gate in the airport, because liquid explosives have been used by the terrorists. However, passengers have a lot of trouble if they cannot bring their own bottles. For example, a mother would like to carry her own milk in the airplane for her baby. Therefore the detection technology of liquid explosives should be developed as soon as possible. This paper shows that near infrared spectroscopy can detect bottled explosives quickly. The transmission method cannot deal with milk in the sense of liquid inspection. Here we examined the reflection method to the test of milk. The inspection method with light cannot make test for the metal can. We also use ultrasonic method to check metal can simultaneously in order to expand test targets.

  4. Evolutionary medicine: bottle feeding, birth spacing, and autism.

    PubMed

    Gallup, Gordon G; Hobbs, Dawn R

    2011-09-01

    To compensate for the high metabolic costs of lactation, the likelihood of re-impregnation shortly after childbirth is normally reduced due to hormonal changes triggered by breast feeding during the postpartum period. Nowadays, however, bottle feeding as a substitute for breast feeding precludes such changes and leads to early postpartum reinstatement of fertility. We suggest that recent data showing the risk of autism goes up dramatically as the time between pregnancies goes down [1] may be a byproduct of bottle feeding. The decision to bottle feed your last child may unwittingly put your next child at risk of being autistic. Copyright © 2011 Elsevier Ltd. All rights reserved.

  5. Flutist produces four resonances with a single bottle

    NASA Astrophysics Data System (ADS)

    Ruiz, Michael J.; Boysen, Erika

    2017-03-01

    In a dramatic physics demonstration, a professional flutist produces four resonances with a 12 ounce Boylan soda bottle solely through her breath control. The 22 cm bottle acts like a Helmholtz resonator for the lowest pitch. The three higher pitches fall near the 3rd, 5th, and 7th harmonics for a 22 cm closed pipe. A video of this remarkable feat is provided (Ruiz 2016 YouTube: Four Resonances with a 12-ounce Soda Bottle (https://youtu.be/ibtVrp2NF_k)). The video also reveals that a flutist can bend resonance pitches by as much as 10% through control of air speed.

  6. Bottle Characteristics of Topical International Glaucoma Medications versus Local Brands in Saudi Arabia

    PubMed Central

    Al-Jumaian, Nasser; Malik, Rizwan; Khandekar, Rajiv; Al-Humaidan, Abdullah; Al-Madany, Rana; Al-Qahtani, Reham; Altowairqi, Ahmed; Al-Theeb, Abdulwahab; Zaman, Babar; Al-Djasim, Leyla; Craven, E. Randy; Edward, Deepak P.

    2016-01-01

    WHAT IS KNOWN AND OBJECTIVE: Physical bottle characteristics differ of brand name topical glaucoma medications and local generic equivalents. This study compares the bottle characteristics of international topical glaucoma brands versus local brands from the Kingdom of Saudi Arabia. METHODS: Data were collected on bottle drum volume, drop volume, bottle squeezability, bottle tip diameter, labels and instructions, cap color coding, and clarity of the drug label. Density-based calculations of drops in bottle volume were assessed using an analytic balance. Bottle tip diameter was measured using 0.05 mm Vernier calipers. A Likert scale-based questionnaire was used to evaluate the subjective opinions of patients on bottle squeezability, clarity of usage and storage instructions, and the consistency of the cap color coding. RESULTS: The volumes of international brands were statistically significantly higher than the local brands (P < 0.001). A number of drops per bottle and tip diameter were comparable between the international local brands. Cap color coding was inconsistent for international and local brands. Patients were dissatisfied with the label font size. Patients reported that the international and local brands were similar in terms of the ease of opening the bottle, instilling a drop, and the clarity of the instructions; but the local brands were subjectively easier to squeeze than international brands. WHAT IS NEW AND CONCLUSIONS: This is the first study to compare bottle characteristics of local Saudi Arabia brands with international brands. The bottle characteristics and patient feedback were similar between the local and international topical glaucoma medications. However, there were differences between the local and international brands in drug volume, bottle squeezability. Hence, patient compliance and drop dosage may differ based on the origin of manufacture. PMID:27994392

  7. 27 CFR 24.255 - Bottling or packing wine.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... in the same tax class when that wine is removed from bond, without benefit of tolerance, when the... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Bottling or packing wine..., DEPARTMENT OF THE TREASURY LIQUORS WINE Storage, Treatment and Finishing of Wine Bottling, Packing, and...

  8. Evaluation of microbial contamination of canine plasma eyedropper bottles following clinical use in canine patients.

    PubMed

    Strauss, Rachel A; Genschel, Ulrike; Allbaugh, Rachel A; Sebbag, Lionel; Ben-Shlomo, Gil

    2018-05-24

    To investigate microbial contamination of canine plasma eye drops when used clinically and to compare the effect of two different eyedropper bottles on contamination rate. Forty-six bottles containing plasma were randomly dispensed for use on 42 dogs with ulcerative keratitis. Of these, 23 were standard eyedropper bottles and 23 were Novelia ® bottles designed to prevent contamination. After use for up to 2 weeks, samples for bacterial culture were obtained from a drop of plasma, the bottle tip, the plasma inside the bottle, and the corneal surface. Fungal culture was performed from a drop of plasma. The overall microbial contamination rate was 17.4% (8/46 bottles); however, only one bottle had growth from the plasma inside the bottle. There was a lower contamination rate of Novelia ® bottles (3/23 = 13.0%) compared to standard bottles (5/23 = 21.7%), but this difference was not statistically significant (P = .57). There were also no significant differences in contamination rate of bottles used greater than 7 days compared to less than or equal to 7 days, or in bottles used greater than 4 times daily compared to 4 times daily or less. Three corneal samples (6.5%) had bacterial growth, but none matched contamination from the bottles. Novelia ® bottles may decrease contamination of plasma eye drops used clinically. However, while microbial contamination of plasma bottles was documented, no clinically relevant complications were observed. This study supports safe use of plasma eye drops for up to 2 weeks when refrigerated and dispensed from either Novelia ® or standard eyedropper bottles. © 2018 American College of Veterinary Ophthalmologists.

  9. Tension amplification in tethered layers of bottle-brush polymers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leuty, Gary M.; Tsige, Mesfin; Grest, Gary S.

    2016-02-26

    In this paper, molecular dynamics simulations of a coarse-grained bead–spring model have been used to study the effects of molecular crowding on the accumulation of tension in the backbone of bottle-brush polymers tethered to a flat substrate. The number of bottle-brushes per unit surface area, Σ, as well as the lengths of the bottle-brush backbones N bb (50 ≤ N bb ≤ 200) and side chains N sc (50 ≤ N sc ≤ 200) were varied to determine how the dimensions and degree of crowding of bottle-brushes give rise to bond tension amplification along the backbone, especially near the substrate.more » From these simulations, we have identified three separate regimes of tension. For low Σ, the tension is due solely to intramolecular interactions and is dominated by the side chain repulsion that governs the lateral brush dimensions. With increasing Σ, the interactions between bottle-brush polymers induce compression of the side chains, transmitting increasing tension to the backbone. For large Σ, intermolecular side chain repulsion increases, forcing side chain extension and reorientation in the direction normal to the surface and transmitting considerable tension to the backbone.« less

  10. Conical Refraction Bottle Beams for Entrapment of Absorbing Droplets.

    PubMed

    Esseling, Michael; Alpmann, Christina; Schnelle, Jens; Meissner, Robert; Denz, Cornelia

    2018-03-22

    Conical refraction (CR) optical bottle beams for photophoretic trapping of airborne absorbing droplets are introduced and experimentally demonstrated. CR describes the circular split-up of unpolarised light propagating along an optical axis in a biaxial crystal. The diverging and converging cones lend themselves to the construction of optical bottle beams with flexible entry points. The interaction of single inkjet droplets with an open or partly open bottle beam is shown implementing high-speed video microscopy in a dual-view configuration. Perpendicular image planes are visualized on a single camera chip to characterize the integral three-dimensional movement dynamics of droplets. We demonstrate how a partly opened optical bottle transversely confines liquid objects. Furthermore we observe and analyse transverse oscillations of absorbing droplets as they hit the inner walls and simultaneously measure both transverse and axial velocity components.

  11. ''Neither fish nor fowl'' EEC draft on bottle recycling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1980-05-20

    It is reported that an EEC directive on drinks bottle recycling is expected to be announced shortly. The directive is expected to call for member countries to make arrangements for the compulsory return of beer and soft drinks bottles.

  12. Recycled poly(ethylene terephthalate) for direct food contact applications: challenge test of an inline recycling process.

    PubMed

    Franz, R; Welle, F

    2002-05-01

    Of all the plastics used for packaging, due to its low diffusivity and chemical inertness, poly(ethylene terephthalate) (PET) is one of the favoured candidate plastics for closed-loop recycling for new packaging applications. In the work reported here, a PET-recycling process was investigated with respect to its cleaning efficiency and compliance of the PET recyclate with food law. The key technology of the investigated PET-recycling process to remove contaminants consists of a predecontamination-extruder combination. At the end of the recycling process, there is either a pelletizing system or downstream equipment to produce preforms or flat sheets. Therefore, the process has two process options, an inline production of PET preforms and a batch option producing PET pellets. In the case of possible misuse of PET bottles by the consumer, the inline process produces higher concentrations in the bottle wall of the recyclate containing preforms. Owing to the dilution of the PET output material by large amounts of uncontaminated PET, the batch option is the less critical process in terms of consumer protection. Regarding an appropriate testing procedure for the evaluation of a bottle-to-bottle recycling process, both process options have their own specific requirements with respect to the design of a challenge test. A novel challenge test approach to the inline mode of a recycling process is presented here.

  13. Improvements to the Whoosh Bottle Rocket Car Demonstration

    ERIC Educational Resources Information Center

    Campbell, Dean J.; Staiger, Felicia A.; Jujjavarapu, Chaitanya N.

    2015-01-01

    The whoosh bottle rocket car has been redesigned to be more reusable and more robust, making it even easier to use as a demonstration. Enhancements of this demonstration, including the use of heat sensitive ink and electronic temperature probes, enable users to find warmer and cooler regions on the surface of the whoosh bottle.

  14. Association Between Bottle Size and Formula Intake in 2-Month-Old Infants.

    PubMed

    Wood, Charles T; Skinner, Asheley C; Yin, H Shonna; Rothman, Russell L; Sanders, Lee M; Delamater, Alan; Ravanbakht, Sophie N; Perrin, Eliana M

    2016-04-01

    To determine range of bottle sizes used and examine the relationship between bottle size and total daily consumption of infant formula. Cross-sectional analysis of baseline data collected as part of Greenlight, a cluster randomized trial to prevent childhood obesity at 4 pediatric resident clinics. The Greenlight study included healthy, term infants. For our analysis, parents of exclusively formula-fed infants reported volume per feed, number of feeds per day, and bottle size, which was dichotomized into small (<6 oz) or large (≥6 oz). We identified determinants of bottle size, and then examined relationships between bottle size and volume fed with log-transformed ordinary least squares regression, adjusting for infant age, sex, birth weight, current weight, race/ethnicity, and enrollment in Special Supplemental Nutrition Program for Women, Infants, and Children. Of 865 participants in the Greenlight study, 44% (n = 378; 21.8% white, 40.6% black, 35.3% Hispanic, 2.4% other) of infants were exclusively formula fed at 2 months. Median volume per day was 30 oz (interquartile range 12), and 46.0% of infants were fed with large bottles. Adjusted for covariates, parents using larger bottles reported feeding 4 oz more formula per day (34.2 oz, 95% confidence interval 33.5-34.9 vs 29.7 oz, 95% confidence interval 29.2-30.3, P = .03). Among exclusively formula-fed infants, use of a larger bottle is associated with parental report of more formula intake compared to infants fed with smaller bottles. If infants fed with larger bottles receive more formula, these infants may be overfed and consequently at risk for obesity. Copyright © 2016 Academic Pediatric Association. Published by Elsevier Inc. All rights reserved.

  15. Comparison of the Mineral Content of Tap Water and Bottled Waters

    PubMed Central

    Azoulay, Arik; Garzon, Philippe; Eisenberg, Mark J

    2001-01-01

    OBJECTIVES Because of growing concern that constituents of drinking water may have adverse health effects, consumption of tap water in North America has decreased and consumption of bottled water has increased. Our objectives were to 1) determine whether North American tap water contains clinically important levels of calcium (Ca2+), magnesium (Mg2+), and sodium (Na+) and 2) determine whether differences in mineral content of tap water and commercially available bottled waters are clinically important. DESIGN We obtained mineral analysis reports from municipal water authorities of 21 major North American cities. Mineral content of tap water was compared with published data regarding commercially available bottled waters and with dietary reference intakes (DRIs). MEASUREMENTS AND MAIN RESULTS Mineral levels varied among tap water sources in North America and among bottled waters. European bottled waters generally contained higher mineral levels than North American tap water sources and North American bottled waters. For half of the tap water sources we examined, adults may fulfill between 8% and 16% of their Ca2+ DRI and between 6% and 31% of their Mg2+ DRI by drinking 2 liters per day. One liter of most moderate mineralization European bottled waters contained between 20% and 58% of the Ca2+ DRI and between 16% and 41% of the Mg2+ DRI in adults. High mineralization bottled waters often contained up to half of the maximum recommended daily intake of Na+. CONCLUSION Drinking water sources available to North Americans may contain high levels of Ca2+, Mg2+, and Na+ and may provide clinically important portions of the recommended dietary intake of these minerals. Physicians should encourage patients to check the mineral content of their drinking water, whether tap or bottled, and choose water most appropriate for their needs. PMID:11318912

  16. Migration of antimony from PET trays into food simulant and food: determination of Arrhenius parameters and comparison of predicted and measured migration data

    PubMed Central

    Haldimann, M.; Alt, A.; Blanc, A.; Brunner, K.; Sager, F.; Dudler, V.

    2013-01-01

    Migration experiments with small sheets cut out from ovenable PET trays were performed in two-sided contact with 3% acetic acid as food simulant at various temperatures. The fraction of diffusible antimony (Sb) was estimated to be 62% in the PET sample under study. Apparent diffusion coefficients of Sb in PET trays were determined experimentally. Measurement of migration between 20 and 150°C yielded a linear Arrhenius plot over a wide temperature range from which the activation energy (Ea) of 188 ± 36 kJ mol−1 and the pre-exponential factor (D0) of 3.6 × 1014 cm2s−1 were determined for diffusing Sb species. Ea was similar to previously reported values for PET bottles obtained with a different experimental approach. Ea and D0 were applied as model parameters in migration modelling software for predicting the Sb transfer in real food. Ready meals intended for preparation in a baking oven were heated in the PET trays under study and the actual Sb migration into the food phase was measured by isotope dilution ICP-MS. It was shown that the predictive modelling reproduces correctly experimental data. PMID:23286325

  17. Migration of antimony from PET trays into food simulant and food: determination of Arrhenius parameters and comparison of predicted and measured migration data.

    PubMed

    Haldimann, M; Alt, A; Blanc, A; Brunner, K; Sager, F; Dudler, V

    2013-01-01

    Migration experiments with small sheets cut out from ovenable PET trays were performed in two-sided contact with 3% acetic acid as food simulant at various temperatures. The fraction of diffusible antimony (Sb) was estimated to be 62% in the PET sample under study. Apparent diffusion coefficients of Sb in PET trays were determined experimentally. Measurement of migration between 20 and 150°C yielded a linear Arrhenius plot over a wide temperature range from which the activation energy (E(a)) of 188 ± 36 kJ mol(-1) and the pre-exponential factor (D(0)) of 3.6 × 10(14) cm(2) s(-1) were determined for diffusing Sb species. E (a) was similar to previously reported values for PET bottles obtained with a different experimental approach. E (a) and D (0) were applied as model parameters in migration modelling software for predicting the Sb transfer in real food. Ready meals intended for preparation in a baking oven were heated in the PET trays under study and the actual Sb migration into the food phase was measured by isotope dilution ICP-MS. It was shown that the predictive modelling reproduces correctly experimental data.

  18. Breast vs bottle: endocrine responses are different with formula feeding.

    PubMed

    Lucas, A; Sarson, D L; Blackburn, A M; Adrian, T E; Aynsley-Green, A; Bloom, S R

    1980-06-14

    Differences in pancreatic and gut-hormone release between breast-fed and bottle-fed infants have not been documented although these hormones may play a key role in postnatal adaptation. In a study of 77 six-day-old healthy term infants, bottle-fed neonates ('Cow and Gate Premium') had significant changes in plasma-concentrations of insulin, motilin, enteroglucagon, neurotensin, and pancreatic polypeptide after feeding, whereas in breast-fed infants these changes were reduced or absent. Basal levels of gastric inhibitory polypeptide, motilin, neurotensin, and vasoactive intestinal peptide were also higher in the bottle-fed infants than in those who were breast-fed. These findings may partly explain differences in the deposition of subcutaneous fat and in stool frequency between breast-fed and bottle-fed neonates.

  19. Blood culture bottles are superior to conventional media for vitreous culture.

    PubMed

    Thariya, Patsuda; Yospaiboon, Yosanan; Sinawat, Suthasinee; Sanguansak, Thuss; Bhoomibunchoo, Chavakij; Laovirojjanakul, Wipada

    2016-08-01

    To compare blood culture bottles and conventional media for the vitreous culture in patients with clinically suspected infectious endophthalmitis. Retrospective comparative study at KKU Eye Center, Khon Kaen University. There were 342 patients with clinically suspected infectious endophthalmitis participated in the study. The vitreous specimens were inoculated in both blood culture bottles and on conventional culture media (blood agar, MacConkey agar, chocolate agar, Sabouraud dextrose agar and thioglycolate broth). The number of positive culture yields in both blood culture bottles and conventional media. Positive culture yields in both methods were found in 151 eyes (49.5%). There were 136 of 151 eyes (90.1%) with positive culture in blood culture bottles, whereas 99 of 151 eyes (65.6%) yielded positive cultures in conventional media. These findings were different with a statistical significance (P < 0.00001) and an odds ratio of 3.47 (95% confidence interval 1.92, 6.63). A combination of blood culture bottles and conventional media improved the yield. Blood culture bottles are superior to conventional media for vitreous culture in clinically suspected infectious endophthalmitis. Vitreous culture using blood culture bottles should be recommended as the primary method for microbiological diagnosis. A combination of both methods further improves the positive culture yield. © 2016 Royal Australian and New Zealand College of Ophthalmologists.

  20. Fluid dynamics following flow shut-off in bottle filling

    NASA Astrophysics Data System (ADS)

    Thete, Sumeet; Appathurai, Santosh; Gao, Haijing; Basaran, Osman

    2012-11-01

    Bottle filling is ubiquitous in industry. Examples include filling of bottles with shampoos and cleaners, engine oil and pharmaceuticals. In these examples, fluid flows out of a nozzle to fill bottles in an assembly line. Once the required volume of fluid has flowed out of the nozzle, the flow is shut off. However, an evolving fluid thread or string may remain suspended from the nozzle following flow shut-off and persist. This stringing phenomenon can be detrimental to a bottle filling operation because it can adversely affect line speed and filling accuracy by causing uncertainty in fill volume, product loss and undesirable marring of the bottles' exterior surfaces. The dynamics of stringing are studied numerically primarily by using the 1D, slender-jet approximation of the flow equations. A novel feature entails development and use of a new boundary condition downstream of the nozzle exit to expedite the computations. While the emphasis is on stringing of Newtonian fluids and use of 1D approximations, results will also be presented for situations where (a) the fluids are non-Newtonian and (b) the full set of equations are solved without invoking the 1D approximation. Phase diagrams will be presented that identify conditions for which stringing can be problematic.

  1. Method development for determination of migrated phthalate acid esters from polyethylene terephthalate (PET) packaging into traditional Iranian drinking beverage (Doogh) samples: a novel approach of MSPE-GC/MS technique.

    PubMed

    Kiani, Amin; Ahmadloo, Mahsa; Shariatifar, Nabi; Moazzen, Mojtaba; Baghani, Abbas Norouzian; Khaniki, GholamReza Jahed; Taghinezhad, Ali; Kouhpayeh, Amin; Mousavi Khaneghah, Amin; Ghajarbeygi, Peyman

    2018-05-01

    In the current study, a novel magnetic solid phase extraction (MSPE) technique combined with a gas chromatography/mass spectroscopy (GC/MS) was developed to determine the phthalate ester content of bottled Doogh samples. Doogh is a yogurt-based drinking beverage, which is frequently consumed in Middle East and Balkans. It is produced by stirring yogurt in Chern separation machine and consists of substances such as water, yogurt, and salt in addition to aqueous extracts of native herbs. The magnetic multi-walled carbon nanotubes (MWCNT-Fe 3 O 4 ) were used as adsorbents of phthalate acid esters (PAEs) due to a superior adsorption capability of hydrophobic compounds. In this context, the quantity of the extractable migrated phthalate esters (dibutyl phthalate (DBP), dimethyl phthalate (DMP), butyl benzyl phthalate (BBP), diethyl phthalate (DEP), di-N-octyl phthalate (DNOP), and bis (2-ethylhexyl) phthalate (DEHP)) from polyethylene terephthalate (PET) bottles into Doogh samples was measured. The correlation between the concentration of migrated PAEs and some factors such as the type of Doogh (gaseous and without gas), difference in brand (five brands), volume (1500 and 300 mL), and the storage time also was investigated. The migration level into Doogh samples was increased by incorporating of gas as well as increasing the volume of PET bottles. Also, with elaborating of storage time, the migration of some phthalates such as DEHP (the mean from 2419.85 ng L -1 in the first week to 2716.15 ng L -1 in the second month), DEP, and total phthalate was increased. However, no significant difference in concentrations of migrated phthalate esters among different examined brands was noted. Finally, the concentration of migrated PAEs from bottle into all the examined Doogh samples was below the defined standards by EPA; 6 μg/L for DEHP in drinking water. Graphical abstract ᅟ.

  2. Profiles in garbage: Polyethylene terephthalate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, C.

    1997-11-01

    Polyethylene terephthalate (PET) is a plastic resin used primarily to make bottles. Soft drinks -- along with salad dressing, fruit juices, peanut butter, and other household and consumer products -- use PET bottles. PET also is used for film, sheeting for cups and food trays, oven-safe trays, and other uses. PET is a relatively new packaging resin, first commercialized in the early 1970s. Because it is an ``engineered`` resin, PET is more expensive than commodity resins such as high-density polyethylene (HDPE) and, for the same reason, it is usually the highest valued plastic recyclable.

  3. Flutist Produces Four Resonances with a Single Bottle

    ERIC Educational Resources Information Center

    Ruiz, Michael J.; Boysen, Erika

    2017-01-01

    In a dramatic physics demonstration, a professional flutist produces four resonances with a 12 ounce Boylan soda bottle solely through her breath control. The 22cm bottle acts like a Helmholtz resonator for the lowest pitch. The three higher pitches fall near the 3rd, 5th, and 7th harmonics for a 22cm closed pipe. A video of this remarkable feat…

  4. Stress-strain response of plastic waste mixed soil.

    PubMed

    Babu, G L Sivakumar; Chouksey, Sandeep Kumar

    2011-03-01

    Recycling plastic waste from water bottles has become one of the major challenges worldwide. The present study provides an approach for the use plastic waste as reinforcement material in soil. The experimental results in the form of stress-strain-pore water pressure response are presented. Based on experimental test results, it is observed that the strength of soil is improved and compressibility reduced significantly with addition of a small percentage of plastic waste to the soil. The use of the improvement in strength and compressibility response due to inclusion of plastic waste can be advantageously used in bearing capacity improvement and settlement reduction in the design of shallow foundations. Copyright © 2010 Elsevier Ltd. All rights reserved.

  5. Evaluation of PET Scanner Performance in PET/MR and PET/CT Systems: NEMA Tests.

    PubMed

    Demir, Mustafa; Toklu, Türkay; Abuqbeitah, Mohammad; Çetin, Hüseyin; Sezgin, H Sezer; Yeyin, Nami; Sönmezoğlu, Kerim

    2018-02-01

    The aim of the present study was to compare the performance of positron emission tomography (PET) component of PET/computed tomography (CT) with new emerging PET/magnetic resonance (MR) of the same vendor. According to National Electrical Manufacturers Association NU2-07, five separate experimental tests were performed to evaluate the performance of PET scanner of General Electric GE company; SIGNATM model PET/MR and GE Discovery 710 model PET/CT. The main investigated aspects were spatial resolution, sensitivity, scatter fraction, count rate performance, image quality, count loss and random events correction accuracy. The findings of this study demonstrated superior sensitivity (~ 4 folds) of PET scanner in PET/MR compared to PET/CT system. Image quality test exhibited higher contrast in PET/MR (~ 9%) compared with PET/CT. The scatter fraction of PET/MR was 43.4% at noise equivalent count rate (NECR) peak of 218 kcps and the corresponding activity concentration was 17.7 kBq/cc. Whereas the scatter fraction of PET/CT was found as 39.2% at NECR peak of 72 kcps and activity concentration of 24.3 kBq/cc. The percentage error of the random event correction accuracy was 3.4% and 3.1% in PET/MR and PET/CT, respectively. It was concluded that PET/MR system is about 4 times more sensitive than PET/CT, and the contrast of hot lesions in PET/MR was ~ 9% higher than PET/CT. These outcomes also emphasize the possibility to achieve excellent clinical PET images with low administered dose and/or a short acquisition time in PET/MR.

  6. Ocular injuries from pressurised bottled drinks in China.

    PubMed

    Zhu, Lili; Lou, Dinghua

    2014-01-01

    The objective of this study is to provide a systematic review on ocular injuries induced by glass bottles containing carbonated drinks in China, which emphasised the injury circumstance and visual function loss. We performed a literature-based retrospective analysis using predetermined inclusion and exclusion criteria. Demographic characteristics of pressurised bottled drinks-related eye injuries were obtained and vision loss was calculated. A total of 26 relevant articles were found suitable for investigation of causative agent and patient demographics, of which 19 articles could be used for calculating vision loss and injury circumstance. Victims were often pertinent workers (46.0%). Most of the trauma was serious and even devastating. Final visual acuity was >10/20 in 29.2%, with severe final vision loss (<10/200) in 30.8%. Visual acuity can improve significantly with treatment (P<0.05). One in three ocular injuries from glass bottles containing carbonated drinks show severe vision loss. Relevant workers are most frequently injured, followed by inappropriate handlers or openers. Besides manufacturing standards being strictly implemented, many ocular traumas related to bottled carbonated drinks should be prevented through health education. Copyright © 2013 Elsevier Ltd. All rights reserved.

  7. Heat Transfer in Glass, Aluminum, and Plastic Beverage Bottles

    ERIC Educational Resources Information Center

    Clark, William M.; Shevlin, Ryan C.; Soffen, Tanya S.

    2010-01-01

    This paper addresses a controversy regarding the effect of bottle material on the thermal performance of beverage bottles. Experiments and calculations that verify or refute advertising claims and represent an interesting way to teach heat transfer fundamentals are described. Heat transfer coefficients and the resistance to heat transfer offered…

  8. 27 CFR 31.203 - Possession of used liquor bottles.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... emptied or elsewhere, including disposition for purposes that will result in the bottles being rendered... collectors' items or for other purposes not involving the packaging of any product for sale; (b) Any person may possess, offer for sale, or sell unusual or distinctive bottles for purposes not involving the...

  9. 27 CFR 31.203 - Possession of used liquor bottles.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... emptied or elsewhere, including disposition for purposes that will result in the bottles being rendered... collectors' items or for other purposes not involving the packaging of any product for sale; (b) Any person may possess, offer for sale, or sell unusual or distinctive bottles for purposes not involving the...

  10. 27 CFR 31.203 - Possession of used liquor bottles.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... emptied or elsewhere, including disposition for purposes that will result in the bottles being rendered... collectors' items or for other purposes not involving the packaging of any product for sale; (b) Any person may possess, offer for sale, or sell unusual or distinctive bottles for purposes not involving the...

  11. 27 CFR 31.203 - Possession of used liquor bottles.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... emptied or elsewhere, including disposition for purposes that will result in the bottles being rendered... collectors' items or for other purposes not involving the packaging of any product for sale; (b) Any person may possess, offer for sale, or sell unusual or distinctive bottles for purposes not involving the...

  12. 27 CFR 31.203 - Possession of used liquor bottles.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... emptied or elsewhere, including disposition for purposes that will result in the bottles being rendered... collectors' items or for other purposes not involving the packaging of any product for sale; (b) Any person may possess, offer for sale, or sell unusual or distinctive bottles for purposes not involving the...

  13. Simulation on Effect of Preform Diameter in Injection Stretch Blow Molding

    NASA Astrophysics Data System (ADS)

    Tan, Z. Q.; Rosli, Nurrina; Oktaviandri, Muchamad

    2018-03-01

    Polyethylene terephthalate (PET) is the most common material of resin for manufacturing plastic bottle by injection stretch blow molding due to its excellent properties. As various issues of health and environmental hazards due to the PET use have risen, PET bottle manufacture may be improved by minimizing the wall thickness to reduce the PET use. One of the critical qualifications of the manufacturing process which lead to the wall thickness distribution is the initial preform diameter. In this project, we used the ANSYS Polyflow with aim to evaluate the wall thickness distribution of PET bottle for different diameter of initial preform. As a result, only 4 mm preform diameter presented wall thickness below than 1 mm. On the other hand, at least 6 mm preform diameter can permit the wall thickness 1.3 mm i.e. at the shoulder area.

  14. Safety evaluation of mechanical recycling processes used to produce polyethylene terephthalate (PET) intended for food contact applications.

    PubMed

    Barthélémy, E; Spyropoulos, D; Milana, M-R; Pfaff, K; Gontard, N; Lampi, E; Castle, L

    2014-01-01

    The development of a scheme for the safety evaluation of mechanical recycling processes for polyethylene terephthalate (PET) is described. The starting point is the adoption of a threshold of toxicological concern such that migration from the recycled PET should not give rise to a dietary exposure exceeding 0.0025 μg kg(-1) bw day(-1), the exposure threshold value for chemicals with structural alerts raising concern for potential genotoxicity, below which the risk to human health would be negligible. It is practically impossible to test every batch of incoming recovered PET and every production batch of recycled PET for all the different chemical contaminants that could theoretically arise. Consequently, the principle of the safety evaluation is to measure the cleaning efficiency of a recycling process by using a challenge test with surrogate contaminants. This cleaning efficiency is then applied to reduce a reference contamination level for post-consumer PET, conservatively set at 3 mg kg(-1) PET for a contaminant resulting from possible misuse by consumers. The resulting residual concentration of each contaminant in recycled PET is used in conservative migration models to calculate migration levels, which are then used along with food consumption data to give estimates of potential dietary exposure. The default scenario, when the recycled PET is intended for general use, is that of an infant weighing 5 kg and consuming every day powdered infant formula reconstituted with 0.75 L of water coming from water bottles manufactured with 100% recycled PET. According to this scenario, it can be derived that the highest concentration of a substance in water that would ensure that the dietary exposure of 0.0025 µg kg(-1) bw day(-1) is not exceeded, is 0.017 μg kg(-1) food. The maximum residual content that would comply with this migration limit depends on molecular weight and is in the range 0.09-0.32 mg kg(-1) PET for the typical surrogate contaminants.

  15. Filling or Draining a Water Bottle with Two Holes

    ERIC Educational Resources Information Center

    Cross, Rod

    2016-01-01

    Three simple experiments are described using a small water bottle with two holes in the side of the bottle. The main challenge is to predict and then explain the observations, but the arrangements can also be used for quantitative measurements concerning hydrostatic pressure, Bernoulli's equation, surface tension and bubble formation.

  16. Modeling of in-use stability for tablets and powders in bottles.

    PubMed

    Waterman, Kenneth C; Chen, Lili; Waterman, Philip; MacDonald, Bruce C; Monahan, Andrew P; Scrivens, Garry

    2016-10-01

    A model is presented for determining the time when an active pharmaceutical ingredient in tablets/powders will remain within its specification limits during an in-use period; that is, when a heat-induction sealed bottle is opened for fixed time periods and where tablets are removed at fixed time points. This model combines the Accelerated Stability Assessment Program to determine the impact on degradation rates of relative humidity (RH) with calculations of the RH as a function of time for the dosage forms under in-use conditions. These calculations, in a conservative approach, assume that the air inside bottles with broached heat-induction seals completely exchanges with the external environment during periods when the bottle remains open. The solid dosages are assumed to sorb water at estimable rates during these openings. When bottles are capped, the moisture vapor transmission rate can be estimated to determine the changing RH inside the bottles between opening events. The impact of silica gel desiccants can also be included in the modeling.

  17. 27 CFR 25.158 - Tax computation for bottled beer.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... bottled beer. 25.158 Section 25.158 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY LIQUORS BEER Tax on Beer Determination of Tax § 25.158 Tax computation for bottled beer. Barrel equivalents for various case sizes are as follows: (a) For U.S. measure...

  18. 27 CFR 25.158 - Tax computation for bottled beer.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... bottled beer. 25.158 Section 25.158 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY LIQUORS BEER Tax on Beer Determination of Tax § 25.158 Tax computation for bottled beer. Barrel equivalents for various case sizes are as follows: (a) For U.S. measure...

  19. 27 CFR 25.158 - Tax computation for bottled beer.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... bottled beer. 25.158 Section 25.158 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY ALCOHOL BEER Tax on Beer Determination of Tax § 25.158 Tax computation for bottled beer. Barrel equivalents for various case sizes are as follows: (a) For U.S. measure...

  20. 27 CFR 25.158 - Tax computation for bottled beer.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... bottled beer. 25.158 Section 25.158 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY ALCOHOL BEER Tax on Beer Determination of Tax § 25.158 Tax computation for bottled beer. Barrel equivalents for various case sizes are as follows: (a) For U.S. measure...

  1. 27 CFR 25.158 - Tax computation for bottled beer.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... bottled beer. 25.158 Section 25.158 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY LIQUORS BEER Tax on Beer Determination of Tax § 25.158 Tax computation for bottled beer. Barrel equivalents for various case sizes are as follows: (a) For U.S. measure...

  2. Community Responses to the Removal of Bottled Water on a University Campus

    ERIC Educational Resources Information Center

    Mikhailovich, Katja; Fitzgerald, Robert

    2014-01-01

    Purpose: This paper aimed to examine the impact of the removal of bottled water on the campus community. This paper presents the findings of a survey conducted at the first Australian university to remove single-use bottled water from sale on a small regional university campus. The removal of bottled water from sale at the university formed part…

  3. Simple Model of a Rolling Water-Filled Bottle on an Inclined Ramp

    ERIC Educational Resources Information Center

    Lin, Shihao; Hu, Naiwen; Yao, Tianchen; Chu, Charles; Babb, Simona; Cohen, Jenna; Sangiovanni, Giana; Watt, Summer; Weisman, Danielle; Klep, James; Walecki, Wojciech J.; Walecki, Eve S.; Walecki, Peter S.

    2015-01-01

    We investigate a water-filled bottle rolling down an incline and ask the following question: is a rolling bottle better described by a model ignoring all internal motion where the bottle is approximated by a material point sliding down an incline, or is it better described by a rigid solid cylinder rolling down the incline without skidding? The…

  4. Infant bottle propping among a low-income urban population in Mexico.

    PubMed

    Pérez-Escamilla, R; Segura-Millán, S; Dewey, K G

    1995-06-01

    The prevalence of bottle propping (permitting an infant to drink from a bottle unattended) and the determinants of this practice at 1 week and 4 months of life were studied in a selected sample of urban women in Hermosillo, Mexico. The sample (n = 165) consisted of mothers planning to breast-feed who gave birth to healthy infants at one of two public hospitals. Data were obtained by interviewing women shortly before they were discharged from the hospital and at about 1 week and 4 months postpartum. Among those mothers giving liquid breast milk substitutes to their infants, the percentage practicing bottle propping increased from 27% at 1 week (n = 20/74) to 67% at 4 months (n = 87/130). Women who practiced bottle propping at 1 week were significantly more likely to continue this practice at 4 months. Bottle propping was significantly more common, both at 1 week and 4 months, among women who had completely weaned their infants than among those who were still combining breast and formula feeding. Multivariate logistic regression indicated that 1-week risk factors for bottle propping were low socioeconomic status, being a multiparous single mother, and being a young mother (< or = 18 years old) with a female infant, while 4-month risk factors were complete weaning, delivery in a "nursery" (versus a "rooming-in") hospital, and lack of support by the mother's partner for breast-feeding. While the possible health risks associated with early bottle propping have not been well defined, the extent of the practice observed in this study suggests that such risks deserve further investigation.

  5. Concentration of ions in selected bottled water samples sold in Malaysia

    NASA Astrophysics Data System (ADS)

    Aris, Ahmad Zaharin; Kam, Ryan Chuan Yang; Lim, Ai Phing; Praveena, Sarva Mangala

    2013-03-01

    Many consumers around the world, including Malaysians, have turned to bottled water as their main source of drinking water. The aim of this study is to determine the physical and chemical properties of bottled water samples sold in Selangor, Malaysia. A total of 20 bottled water brands consisting of `natural mineral (NM)' and `packaged drinking (PD)' types were randomly collected and analyzed for their physical-chemical characteristics: hydrogen ion concentration (pH), electrical conductivity (EC) and total dissolved solids (TDS), selected major ions: calcium (Ca), potassium (K), magnesium (Mg) and sodium (Na), and minor trace constituents: copper (Cu) and zinc (Zn) to ascertain their suitability for human consumption. The results obtained were compared with guideline values recommended by World Health Organization (WHO) and Malaysian Ministry of Health (MMOH), respectively. It was found that all bottled water samples were in accordance with the guidelines set by WHO and MMOH except for one sample (D3) which was below the pH limit of 6.5. Both NM and PD bottled water were dominated by Na + K > Ca > Mg. Low values for EC and TDS in the bottled water samples showed that water was deficient in essential elements, likely an indication that these were removed by water treatment. Minerals like major ions were present in very low concentrations which could pose a risk to individuals who consume this water on a regular basis. Generally, the overall quality of the supplied bottled water was in accordance to standards and guidelines set by WHO and MMOH and safe for consumption.

  6. A comparison of bottles and snap traps for short-term small mammal sampling

    Treesearch

    James F. Taulman; Ronald E. Thill; T. Bently Wigley; M. Anthony Melchiors

    1992-01-01

    Bottles were tested as traps for small mammals. Used in conjunction with three types of snap traps over 30,240 trap nights, bottles captured eight (2%) of the total 421 mammals taken. Bottles were inefficient in capturing small mammals compared to snap traps.

  7. Detection algorithm for glass bottle mouth defect by continuous wavelet transform based on machine vision

    NASA Astrophysics Data System (ADS)

    Qian, Jinfang; Zhang, Changjiang

    2014-11-01

    An efficient algorithm based on continuous wavelet transform combining with pre-knowledge, which can be used to detect the defect of glass bottle mouth, is proposed. Firstly, under the condition of ball integral light source, a perfect glass bottle mouth image is obtained by Japanese Computar camera through the interface of IEEE-1394b. A single threshold method based on gray level histogram is used to obtain the binary image of the glass bottle mouth. In order to efficiently suppress noise, moving average filter is employed to smooth the histogram of original glass bottle mouth image. And then continuous wavelet transform is done to accurately determine the segmentation threshold. Mathematical morphology operations are used to get normal binary bottle mouth mask. A glass bottle to be detected is moving to the detection zone by conveyor belt. Both bottle mouth image and binary image are obtained by above method. The binary image is multiplied with normal bottle mask and a region of interest is got. Four parameters (number of connected regions, coordinate of centroid position, diameter of inner cycle, and area of annular region) can be computed based on the region of interest. Glass bottle mouth detection rules are designed by above four parameters so as to accurately detect and identify the defect conditions of glass bottle. Finally, the glass bottles of Coca-Cola Company are used to verify the proposed algorithm. The experimental results show that the proposed algorithm can accurately detect the defect conditions of the glass bottles and have 98% detecting accuracy.

  8. Fluoride and bacterial content of bottled drinking water versus municipal tap water.

    PubMed

    Mythri, H; Chandu, G N; Prashant, G M; Subba Reddy, V V

    2010-01-01

    Water is a divine gift. People quench their thirst without questioning the source of water. But, apprehension about contaminants in municipal water supplies along with increased fear of fluorosis made bottled drinking water as one of the important tradable commodities. The objectives of the study were to determine and compare the fluoride and bacterial contents of commercially available bottled drinking water and municipal tap water in Davangere city, Karnataka. Fifty samples of 10 categories of bottled drinking water with different batch numbers were purchased and municipal water from different sources were collected. Fluoride levels were determined by an ion-selective electrode. Water was cultured quantitatively and levels of bacteria were calculated as colony-forming units (CFUs) per milliliter. Descriptive analysis of water samples for fluoride concentration was in the range of 0.07-0.33 for bottled drinking water, Bisleri showing the highest of 0.33. A comparison of the mean values of microbial count for bottled drinking water with that of municipal tap water showed no statistically significant difference, but was more than the standard levels along with the presence of fungus and maggots. The fluoride concentration was below the optimal level for both municipal tap water and bottled drinking water. CFUs were more than the recommended level in both municipal tap water and bottled drinking water.

  9. PET/MRI: Where Might It Replace PET/CT?

    PubMed Central

    Ehman, Eric C.; Johnson, Geoffrey B.; Villanueva-Meyer, Javier E.; Cha, Soonmee; Leynes, Andrew Palmera; Larson, Peder Eric Zufall; Hope, Thomas A.

    2017-01-01

    Simultaneous positron emission tomography and MRI (PET/MRI) is a technology that combines the anatomic and quantitative strengths of MR imaging with physiologic information obtained from PET. PET and computed tomography (PET/ CT) performed in a single scanning session is an established technology already in widespread and accepted use worldwide. Given the higher cost and complexity of operating and interpreting the studies obtained on a PET/MRI system, there has been question as to which patients would benefit most from imaging with PET/MRI versus PET/CT. In this article, we compare PET/MRI with PET/CT, detail the applications for which PET/MRI has shown promise and discuss impediments to future adoption. It is our hope that future work will prove the benefit of PET/MRI to specific groups of patients, initially those in which PET/CT and MRI are already performed, leveraging simultaneity and allowing for greater degrees of multiparametric evaluation. PMID:28370695

  10. Investigating the Stability of a Bottle Filled with Different Amounts of Fluid

    ERIC Educational Resources Information Center

    Pahwa, Gantavya; Pingali, Rushil G.; Khubchandani, Aashish K.; Roy, Ekansh; Mudaliyar, Roshni R.; Mudaliyar, Rajesh P.

    2017-01-01

    The aim of this paper is to investigate the stability of a bottle filled with different volumes of water, and to determine the angle at which it topples over for each volume of water. Data for the angle at which the bottle toppled were gathered experimentally using a cylindrical 1 litre bottle, and two theoretical models were then developed,…

  11. "New" Compounds from Old Plastics: Recycling PET Plastics via Depolymerization. An Activity for the Undergraduate Organic Lab

    NASA Astrophysics Data System (ADS)

    Kaufman, Don; Wright, Geoff; Kroemer, Ryan; Engel, Josh

    1999-11-01

    This paper describes work done to develop a meaningful undergraduate organic lab activity that illustrates chemistry of the real world while utilizing reactions typically included in the organic lecture and lab. We show how a common plastic can be converted into several compounds using ester hydrolysis and SN2 reactions. Contributing to the critical shortage of landfill space faced by many communities is the large quantity of plastic refuse. Thus, there is a real need to recycle plastic products. One way to recycle plastics such as polyethyleneterephthalate (PET), the polyester from which numerous consumer products such as 2-liter soda bottles are made, is to depolymerize them and then to use the resulting monomers to produce new products. PET is industrially depolymerized via an acid-catalyzed transesterification reaction conducted under conditions of high temperature and pressure that are not feasible in the undergraduate lab. Despite literature reports that PET is remarkably resistant to hydrolysis, we found that PET can be readily hydrolyzed by refluxing with potassium hydroxide or potassium tert-butoxide in amyl alcohol to give terephthalic acid in high yield. It is then possible to readily synthesize terephthalate diesters via SN2 reactions of ammonium terephthalate salts with alkyl halides. Fischer esterification can also be used to prepare the diesters, but yields are significantly lower.

  12. A study of commercially-available polyethylene terephthalate (PET) and polycarbonate as nuclear track detector materials

    NASA Astrophysics Data System (ADS)

    Espinosa, G.; Golzarri, J. I.; Vazquez-Lopez, C.; Trejo, R.; Lopez, K.; Rickards, J.

    2014-07-01

    In the study of the sensitivity of materials to be used as nuclear track detectors, it was found that commercial polyethylene terephthalate (PET) from Ciel® water bottles, commercial roof cover polycarbonate, and recycled packaging strips (recycled PET), can be used as nuclear track detectors. These three commercial materials present nuclear tracks when bombarded by 2.27 MeV nitrogen ions produced in a Pelletron particle accelerator, and by fission fragments from a 252Cf source (79.4 and 103.8 MeV), after a chemical etching with a 6.25M KOH solution, or with a 6.25M KOH solution with 20% methanol, both solutions at 60±1°C. As an example, the nitrogen ions deposit approximately 1 keV/nm in the form of ionization and excitation at the surface of PET, as calculated using the SRIM code. The fission fragments deposit up to 9 keV/nm at the surface, in both cases generating sufficient free radicals to initiate the track formation process. However, 5 MeV alpha particles, typical of radon (222Rn) emissions, deposit only 0.12 keV/nm, do not present tracks after the chemical etching process. This valuable information could be very useful for further studies of new materials in nuclear track methodology.

  13. Perceptions on the use of bottled water in restaurants in Harare's Central Business District (CBD)

    NASA Astrophysics Data System (ADS)

    Juba, Olivia Sakhile; Tanyanyiwa, Vincent Itai

    2018-06-01

    Bottled water use continues to expand worldwide and in the last two decades, a significant number of consumers have shifted from tap water to bottled water due to Cryptosporidium outbreaks. Bottled water consumption has increased in Harare due to erratic tap water supplies. Since 2011, forty bottled water brands have been banned because of failure to meet safety and quality standards due to contamination, unsuitable packaging, and wrong labelling. Nevertheless, the bottled water industry continues to thrive as local authorities fail to adequately purify municipal water. The study assessed the perceptions on drinking bottled water in restaurants within Harare's CBD. Demographic and social factors associated with bottled water users were established and the role and influence of stakeholders in bottling and distribution of water documented. A field survey through the administration of questionnaires to fifty restaurant users was carried out to assess the perceptions of people on the use of bottled water in terms of its safety and potential health benefits. Key informant interviews were conducted using a semi-structured interview with ten local water bottling companies as well as representatives from the Environmental Management Agency (EMA) and Standards Association of Zimbabwe (SAZ). Data were analysed using descriptive statistics and logistic regression analysis. Standard descriptive statistics were generated, with 95% confidence intervals (95% CIs). Consumers used bottled water as their primary drinking water source when they perceived that tap water was not safe. Perceptions of purity of water, bottled water convenience, and tap water unavailability seemed to determine consumption patterns among users. Females in the 18-48 age groups were more likely to think that bottled water was cleaner, safer, tasted better and was more convenient than tap water. Consumers regularly purchased bottled water for drinking and used bottled water as their primary drinking water

  14. Comparison of PET/CT with Sequential PET/MRI Using an MR-Compatible Mobile PET System.

    PubMed

    Nakamoto, Ryusuke; Nakamoto, Yuji; Ishimori, Takayoshi; Fushimi, Yasutaka; Kido, Aki; Togashi, Kaori

    2018-05-01

    The current study tested a newly developed flexible PET (fxPET) scanner prototype. This fxPET system involves dual arc-shaped detectors based on silicon photomultipliers that are designed to fit existing MRI devices, allowing us to obtain fused PET and MR images by sequential PET and MR scanning. This prospective study sought to evaluate the image quality, lesion detection rate, and quantitative values of fxPET in comparison with conventional whole-body (WB) PET and to assess the accuracy of registration. Methods: Seventeen patients with suspected or known malignant tumors were analyzed. Approximately 1 h after intravenous injection of 18 F-FDG, WB PET/CT was performed, followed by fxPET and MRI. For reconstruction of fxPET images, MRI-based attenuation correction was applied. The quality of fxPET images was visually assessed, and the number of detected lesions was compared between the 2 imaging methods. SUV max and maximum average SUV within a 1 cm 3 spheric volume (SUV peak ) of lesions were also compared. In addition, the magnitude of misregistration between fxPET and MR images was evaluated. Results: The image quality of fxPET was acceptable for diagnosis of malignant tumors. There was no significant difference in detectability of malignant lesions between fxPET and WB PET ( P > 0.05). However, the fxPET system did not exhibit superior performance to the WB PET system. There were strong positive correlations between the 2 imaging modalities in SUV max (ρ = 0.88) and SUV peak (ρ = 0.81). SUV max and SUV peak measured with fxPET were approximately 1.1-fold greater than measured with WB PET. The average misregistration between fxPET and MR images was 5.5 ± 3.4 mm. Conclusion: Our preliminary data indicate that running an fxPET scanner near an existing MRI system provides visually and quantitatively acceptable fused PET/MR images for diagnosis of malignant lesions. © 2018 by the Society of Nuclear Medicine and Molecular Imaging.

  15. Wooden beverage cases cause little damage to bottle caps

    Treesearch

    R. Bruce Anderson; William C. Miller

    1973-01-01

    Wooden beverage cases cause little damage to aluminum resealable caps during distribution. A study at bottling plants and distribution warehouses showed that an average of 1 bottle out of 4,000 has cap damage. Most of the damage was attributed to handling at the warehouse and in transit. Some recommendations are given for improvement of wooden beverage cases to prevent...

  16. Design and performance of a vacuum-bottle solid-state calorimeter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bracken, D.S.; Biddle, R.; Cech, R.

    1997-11-01

    EG and G Mound Applied Technologies calorimetry personnel have developed a small, thermos-bottle solid-state calorimeter, which is now undergoing performance testing at Los Alamos National Laboratory. The thermos-bottle solid-state calorimeter is an evaluation prototype for characterizing the heat output of small heat standards and other homogeneous heat sources. The current maximum sample size is 3.5 in. long with a diameter of 0.8 in. The overall size of the thermos bottle and thermoelectric cooling device is 9.25 in. high by 3.75 in. diameter and less than 3 lb. Coupling this unit with compact electronics and a laptop computer makes this calorimetermore » easily hand carried by a single individual. This compactness was achieved by servo controlling the reference temperature below room temperature and replacing the water bath used in conventional calorimeter design with the thermos-bottle insulator. Other design features will also be discussed. The performance of the calorimeter will be presented.« less

  17. Degradation and depolymerization of plastic waste by local bacterial isolates and bubble column reactor

    NASA Astrophysics Data System (ADS)

    Hussein, Amal A.; Alzuhairi, Mohammed; Aljanabi, Noor H.

    2018-05-01

    Accumulation of plastics, especially Polyethylene terephthalate (PET), is an ever increasing ecological threat due to its excessive usage in everyday human life. Nowadays, there are many methods to get rid of plastic wastes including burning, recycling and burying. However, these methods are not very active since their long period, anaerobic conditions that increase the rate of toxic materials released into the environment. This work aims to study the biological degradation of PET microorganism isolated from soil sample. Thirty eight (38) bacterial isolates were isolated from ten soil and plastic waste sample collected from four different waste disposal sites in Baghdad city during different periods between December 2016 and March 2017. Isolation was performed using enrichment culture method (flasks method) by culturing the soil samples in flasks with MSM medium where there is no carbon source only PET. Results showed that Al-Za'farania sample gave a higher number of isolates (13 isolates), while other samples gave less number of isolates. Screening was performed depending on their ability to grow in liquid MSM which contains PET powder and pieces and change the color of the PET-emulsified liquid medium as well as their ability to form the clear zone on PET-MSM agar. The results showed that NH-D-1 isolate has the higher ability to degrade DPET and PET pieces. According to morphological, biochemical characterization and Vitek-2 technique, the most active isolate was identified as Acinetobacter baumannii.

  18. Pet Problems at Home: Pet Problems in the Community.

    ERIC Educational Resources Information Center

    Soltow, Willow

    1984-01-01

    Discusses problems of pets in the community, examining the community's role related to disruptive pets and pet overpopulation. Also discusses pet problems at home, offering advice on selecting a pet, meeting a pet's needs, and disciplining pets. Includes a list of books, films/filmstrips, teaching materials, and various instructional strategies.…

  19. 27 CFR 19.384 - Preparation of bottling or packaging record.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... packaging record. 19.384 Section 19.384 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND... Than Denaturation and Manufacture of Articles Bottling, Packaging, and Removal of Products § 19.384 Preparation of bottling or packaging record. The proprietor shall prepare a record for each batch of spirits...

  20. Development of characterization protocol for mixed liquid radioactive waste classification

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zakaria, Norasalwa, E-mail: norasalwa@nuclearmalaysia.gov.my; Wafa, Syed Asraf; Wo, Yii Mei

    2015-04-29

    Mixed liquid organic waste generated from health-care and research activities containing tritium, carbon-14, and other radionuclides posed specific challenges in its management. Often, these wastes become legacy waste in many nuclear facilities and being considered as ‘problematic’ waste. One of the most important recommendations made by IAEA is to perform multistage processes aiming at declassification of the waste. At this moment, approximately 3000 bottles of mixed liquid waste, with estimated volume of 6000 litres are currently stored at the National Radioactive Waste Management Centre, Malaysia and some have been stored for more than 25 years. The aim of this studymore » is to develop a characterization protocol towards reclassification of these wastes. The characterization protocol entails waste identification, waste screening and segregation, and analytical radionuclides profiling using various analytical procedures including gross alpha/ gross beta, gamma spectrometry, and LSC method. The results obtained from the characterization protocol are used to establish criteria for speedy classification of the waste.« less

  1. Plasma sterilization of polyethylene terephthalate bottles by pulsed corona discharge at atmospheric pressure.

    PubMed

    Masaoka, Satoshi

    2007-06-01

    A pulsed power supply was used to generate a corona discharge on a polyethylene terephthalate bottle, to conduct plasma sterilization at atmospheric pressure. Before generating such a discharge, minute quantities of water were attached to the inner surface of the bottle and to the surface of a high voltage (HV) electrode inserted into the bottle. Next, high-voltage pulses of electricity were discharged between electrodes for 6.0s, while rotating the bottle. The resulting spore log reduction values of Bacillus subtilis and Aspergillus niger on the inner surface of the bottle were 5.5 and 6 or higher, respectively, and those on the HV electrode surface were each 6 or higher for both strains. The presence of the by-products gaseous ozone, hydrogen peroxide, and nitric ions resulting from the electrical discharge was confirmed.

  2. Separation of polyethylene terephthalate from municipal waste plastics by froth flotation for recycling industry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Chong-Qing; Wang, Hui, E-mail: huiwang1968@163.com; Liu, You-Nian

    Highlights: • Factors of NaOH treatment were studied by orthogonal and single factor experiments. • Mechanism of alkaline treatment for facilitating flotation was manifested. • Flotation separation of PET was achieved with high purity and efficiency. • A flow sheet of purification PET from MWP was designed. - Abstract: Recycling is an effective way to manage plastic wastes and receives considerable attention. Since plastic mixtures are difficult to recycle because of their intrinsic characteristics, separation of mixed plastics is the key problem for recycling. Separation of polyethylene terephthalate (PET) from municipal waste plastics (MWP) by froth flotation combined with alkalinemore » pretreatment was investigated for recycling industry. The effect of process variables was estimated by L{sub 9} (3{sup 4}) orthogonal array of experiments and single factor experiments. The optimum conditions of alkaline pretreatment are 10 wt% sodium hydroxide, 20 min and 70 °C. After alkaline pretreatment under optimum conditions, flotation separation PET from acrylonitrile–butadiene–styrene, polystyrene, polycarbonate or polyvinyl chloride was achieved with high purity and efficiency. The purity of PET is up to 98.46% and the recovery is above 92.47%. A flow sheet of separation PET from MWP by a combination of froth flotation and sink float separation was designed. This study facilitates industrial application of plastics flotation and provides technical insights into recycling of waste plastics.« less

  3. Determination of water vapor transmission rate (WVTR) of HDPE bottles for pharmaceutical products.

    PubMed

    Chen, Yisheng; Li, Yanxia

    2008-06-24

    The objective of this study was to investigate the effects of experimental conditions for measuring the water vapor transmission rate (WVTR) of high-density polyethylene (HDPE) bottles using a steady-state sorption method. Bottles were filled with desiccant, closed with caps and heat induction sealed, and then stored in stability chambers at controlled temperature and relative humidity. Weight gain of the bottles was determined every 1 or 2 weeks until a linear weight gain profile was obtained. WVTR of the bottles was determined from the slope of the linear portion of the weight gain versus time profile. The effects of desiccants and temperature/humidity were studied. Results show that, with a sufficient amount of anhydrous calcium chloride in bottles, a negligibly low and sufficiently constant headspace humidity is maintained, and a steady-state permeation rate is achieved. For all 8 sizes of bottles used in this study, steady-state was achieved in 1 or 2 weeks after the experiment was started. This method provided reproducible WVTR data for HDPE bottles. Apparent moisture permeability of all 8 sizes of bottles was (2.3+/-0.3)x10(-7), (2.6+/-0.2)x10(-7), and (3.4+/-0.2)x10(-7)cm(2)/s at 25 degrees C, 30 degrees C, 40 degrees C, respectively. Moisture permeability determined from the current study was similar to data reported in the literature, indicating that the steady-state weight gain method can be used to obtain reliable WVTR of containers for pharmaceutical products.

  4. Separation of polyethylene terephthalate from municipal waste plastics by froth flotation for recycling industry.

    PubMed

    Wang, Chong-Qing; Wang, Hui; Liu, You-Nian

    2015-01-01

    Recycling is an effective way to manage plastic wastes and receives considerable attention. Since plastic mixtures are difficult to recycle because of their intrinsic characteristics, separation of mixed plastics is the key problem for recycling. Separation of polyethylene terephthalate (PET) from municipal waste plastics (MWP) by froth flotation combined with alkaline pretreatment was investigated for recycling industry. The effect of process variables was estimated by L9 (3(4)) orthogonal array of experiments and single factor experiments. The optimum conditions of alkaline pretreatment are 10 wt% sodium hydroxide, 20 min and 70°C. After alkaline pretreatment under optimum conditions, flotation separation PET from acrylonitrile-butadiene-styrene, polystyrene, polycarbonate or polyvinyl chloride was achieved with high purity and efficiency. The purity of PET is up to 98.46% and the recovery is above 92.47%. A flow sheet of separation PET from MWP by a combination of froth flotation and sink float separation was designed. This study facilitates industrial application of plastics flotation and provides technical insights into recycling of waste plastics. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. Prevalence of baby bottle versus breastfeeding graphics on products in national chain stores.

    PubMed

    Gellerson, Daphne; Hornsby, Paige P; Lowenhaupt, Stephanie A; Bressler, Colleen J; Burns, Whitney R; Friedman, Caroline F; Vaughn, Natalie H; Marshall, Stephanie P; Marshall, Trisha L; Park, Jennie; Kellams, Ann

    2012-12-01

    This study surveyed the prevalence of bottle versus breastfeeding graphic images on products marketed for pregnant mothers and young children available for purchase in national chain stores. This was a product survey/content analysis. Eighteen national chain stores located in a 10-mile radius of Charlottesville, VA were visited. In total, 2,670 individual items in 11 categories of baby shower and baby gift merchandise (shower invitations, greeting cards, gift wrap, shower decorations, baby dolls, baby books, infant clothing, bibs, nursery decorations, baby blankets, and disposable diapers) were assessed. The main outcome measures were prevalences of baby bottle and breastfeeding graphic images. Baby bottle images were found on products in eight of the 11 categories of items surveyed. Thirty-five percent of baby dolls were marketed with a baby bottle. The prevalence of bottle images on items in all other categories, however, was low. Of the 2,670 items surveyed, none contained a breastfeeding image. The low prevalence of baby bottle images on commonly purchased baby gift and baby shower items is encouraging. However, the absence of breastfeeding images and the relatively high prevalence of baby dolls marketed with a baby bottle demonstrate that breastfeeding is not portrayed as the physiologic norm on these products. Product designers should explore ways to promote breastfeeding, consumers should make informed choices in product selection, and advocacy groups should promote guidelines for these products.

  6. Mothers' experiences of bottle-feeding: a systematic review of qualitative and quantitative studies.

    PubMed

    Lakshman, R; Ogilvie, D; Ong, K K

    2009-08-01

    Most babies receive at least some formula milk. Variations in formula-feeding practices can have both short- and long-term health consequences. The literature on parents' experiences of bottle-feeding was systematically reviewed to understand how formula-feeding decisions are made. Relevant English-language papers, identified by searching 12 electronic databases, reference lists and related articles and by contacting first authors of included papers, were systematically searched for and appraised. The included studies were analysed and synthesised using a combination of narrative and thematic approaches. Consensus on the final inclusion, interpretation and synthesis of studies was reached across the research team. Six qualitative studies and 17 quantitative studies (involving 13 263 participants) were included. Despite wide differences in study design, context, focus and quality, several consistent themes emerged. Mothers who bottle-fed their babies experienced negative emotions such as guilt, anger, worry, uncertainty and a sense of failure. Mothers reported receiving little information on bottle-feeding and did not feel empowered to make decisions. Mistakes in preparation of bottle-feeds were common. No studies examined how mothers made decisions about the frequency or quantity of bottle-feeds. Inadequate information and support for mothers who decide to bottle-feed may put the health of their babies at risk. While it is important to promote breastfeeding, it is also necessary to ensure that the needs of bottle-feeding mothers are met.

  7. Head Start Combats Baby Bottle Tooth Decay Among Native American Families.

    ERIC Educational Resources Information Center

    Phillips, Margaret G.; Stubbs, Phyllis E.

    1987-01-01

    Presents current developments concerning nursing bottle caries--"baby bottle tooth decay"--and spotlights a program funded by Head Start to reduce the prevalence of these painful and disfiguring, but preventable, children's dental diseases among American Indians and Alaska Native families. (Author/BB)

  8. SmartStuff: A case study of a smart water bottle.

    PubMed

    Jovanov, Emil; Nallathimmareddygari, Vindhya R; Pryor, Jonathan E

    2016-08-01

    The rapid growth of Internet of Things (IoT) and miniature wearable biosensors have generated new opportunities for personalized eHealth and mHealth services. Smart objects equipped with physiological sensors can provide robust monitoring of activities of daily living and context for wearable physiological sensors. We present a case study of an intelligent water bottle that can precisely measure the amount of liquid in the bottle, monitor activity using inertial sensors, and physiological parameters using a touch and photoplethysmographic sensor. We evaluate two system configurations: a smart water bottle integrated into a personal body sensor network and a cloud based device. This paper presents system organization and the results from preliminary field testing of the prototype device.

  9. Organochlorine pesticides residues in bottled drinking water from Mexico City.

    PubMed

    Díaz, Gilberto; Ortiz, Rutilio; Schettino, Beatriz; Vega, Salvador; Gutiérrez, Rey

    2009-06-01

    This work describes concentrations of organochlorine pesticides in bottled drinking water (BDW) in Mexico City. The results of 36 samples (1.5 and 19 L presentations, 18 samples, respectively) showed the presence of seven pesticides (HCH isomers, heptachlor, aldrin, and p,p'-DDE) in bottled water compared with the drinking water standards set by NOM-127-SSA1-1994, EPA, and World Health Organization. The concentrations of the majority of organochlorine pesticides were within drinking water standards (0.01 ng/mL) except for beta-HCH of BW 3, 5, and 6 samples with values of 0.121, 0.136, and 0.192 ng/mL, respectively. It is important monitoring drinking bottled water for protecting human health.

  10. Plastic solid waste utilization technologies: A Review

    NASA Astrophysics Data System (ADS)

    Awasthi, Arun Kumar; Shivashankar, Murugesh; Majumder, Suman

    2017-11-01

    Plastics are used in more number of applications in worldwide and it becomes essential part of our daily life. In Indian cities and villages people use the plastics in buying vegetable as a carry bag, drinking water bottle, use of plastic furniture in home, plastics objects uses in kitchen, plastic drums in packing and storage of the different chemicals for industrial use, use plastic utensils in home and many more uses. After usage of plastics it will become part of waste garbage and create pollution due to presence of toxic chemicals and it will be spread diseases and give birth to uncontrolled issues in social society. In current scenario consumption of plastic waste increasing day by day and it is very difficult to manage the plastic waste. There are limited methodologies available for reutilization of plastic waste again. Such examples are recycling, landfill, incineration, gasification and hydrogenation. In this paper we will review the existing methodologies of utilization of plastic waste in current scenario

  11. "Bottled or Tap?" A Controversy for Science, Economics, and Society

    ERIC Educational Resources Information Center

    Lapham, Steven S.

    2009-01-01

    Every year, Americans spend billions of dollars on bottled water. They purchase a bottle from the vending machine or buy a case at the grocery, no longer considering the water that's freely available from their taps. As consumers and as citizens, however, Americans should pause to study the personal and public consequences of this choice. In this…

  12. Catalytic thermal cracking of post-consumer waste plastics to fuels: Part 1 - Kinetics and optimization

    USDA-ARS?s Scientific Manuscript database

    Thermogravimetric analysis (TGA) was used to investigate thermal and catalytic pyrolysis of waste plastics such as prescription bottles (polypropylene/PP), high density polyethylene, landfill liners (polyethylene/PE), packing materials (polystyrene/PS), and foams (polyurethane/PU) into crude plastic...

  13. Ocular injuries from exploding glass-bottled Coca-Cola® drinks in Port Harcourt, Nigeria.

    PubMed

    Pedro-Egbe, Chinyere Nnenne; Ejimadu, Chibuike Sydney; Nwachukwu, Henrietta

    2011-01-01

    Eye injuries and subsequent loss of vision from the glass and caps of exploding pressurized bottled drinks have been well reported, and as a result most developed countries now use mainly plastic bottles. In Nigeria, however, most drinks are still sold in glass bottles and ocular injuries from this source are therefore not uncommon. To retrospectively analyze ocular injuries resulting from exploding glass-bottled Coca-Cola® and propose ways of eliminating such injuries in future. Eye Clinic, University of Port Harcourt Teaching Hospital, Port Harcourt, Nigeria. The medical records of all cases of ocular injury that presented at the Eye Clinic of the University of Port Harcourt Teaching Hospital over a 5-year period (January 2006 to December 2010) were retrieved and relevant data including age, sex, occupation, events surrounding bottle explosion, and type of ocular injury sustained were extracted. A total of 426 cases of ocular injuries was seen during the period under review. There were 335 (78.6%) males and 91 (21.4%) females. Six patients had ocular injury from exploding glass-bottled Coca-Cola®, giving an incidence of 1.4%. The presenting visual acuities (VA) were light perception (2 cases), counting fingers (2 cases), and 1 VA of 6/24 and 1 VA of 6/12. There were 4 (66.7%) cases of corneoscleral laceration with uveal prolapse and 1 case of total hyphema. Because pressurized glass-bottles can explode with normal handling, legislation to ban the use of glass containers for bottling carbonated drinks will go a long way to reducing ocular morbidity from this source. Plastic bottles should be introduced as an alternative.

  14. Public perception and economic implications of bottled water consumption in underprivileged urban areas.

    PubMed

    Massoud, M A; Maroun, R; Abdelnabi, H; Jamali, I I; El-Fadel, M

    2013-04-01

    This paper presents a comparative assessment of public perception of drinking water quality in two underprivileged urban areas in Lebanon and Jordan with nearly similar cultural and demographic characteristics. It compares the quality of bottled water to the quality of the drinking water supplied through the public network and examines the economic implications of bottled water consumption in the two study areas. Participants' perception of the quality of drinking water provided via the public network was generally negative, and bottled water was perceived to be of better quality in both areas, thus affecting drinking water preferences and consumption patterns. The results reveal that the quality of bottled water is questionable in areas that lack enforcement of water quality standards, thus adding to the burden of an already disadvantaged community. Both areas demonstrated a considerable cost incurred for purchasing bottled water in low income communities reaching up to 26 % of total income.

  15. Relieving Dry Mouth: Varying Levels of pH Found in Bottled Water.

    PubMed

    Fisher, Bailey Jean; Spencer, Angela; Haywood, Van; Konchady, Gayathri

    2017-07-01

    It is estimated that 30% of people older than 60 years suffer from hyposalivation or dry mouth. Drinking water frequently has been recommended as a safe, non-pharmacologic way to combat hyposalivation. The saliva in patients with dry mouth is acidic. Beverages consumed daily may have an erosive potential on teeth. The pH and the mineral content of the beverage determine its erosive potential. An acidic beverage, therefore, may have harmful effects on mineralized tooth structures, causing erosion of enamel, dentin, and cementum. Because bottled water is both convenient and easily available, the authors tested the pH of eight common brands of bottled water. (One brand included two different bottle types, for a total of nine bottled waters tested.) To standardize the pH electrode, pH buffers of 4.7 and 10 were used. The pH was measured using the Denver Instruments basic pH meter. Six recordings were used for each brand and then averaged to report the pH. Two of the bottled water samples tested were below the critical level of 5.2 pH to 5.5 pH, the level at which erosion of enamel occurs. Six of the samples tested were below the critical pH of 6.8, at which erosion of root dentin occurs. The authors conclude that both patients and clinicians incorrectly presume bottled water to be innocuous. Clinicians should be cognizant of the erosive potential of different brands of bottled water to both educate patients and to recommend water with neutral or alkaline pH for patients with symptoms of dry mouth to prevent further deterioration and demineralization of tooth structure.

  16. Design, Development and Testing of Inconel Alloy IN718 Spherical Gas Bottle for Oxygen Storage

    NASA Astrophysics Data System (ADS)

    Chenna Krishna, S.; Agilan, M.; Sudarshan Rao, G.; Singh, Satish Kumar; Narayana Murty, S. V. S.; Venkata Narayana, Ganji; Beena, A. P.; Rajesh, L.; Jha, Abhay K.; Pant, Bhanu

    2017-11-01

    This paper describes the details of design, manufacture and testing of 200 mm diameter spherical gas bottle of Inconel 718 (IN718) with nominal wall thickness of 2.3 mm. Gas bottle was designed for the specified internal pressure loading with a thickness of 2.9 mm at the circumferential weld which was brought down to 2.3 mm at the membrane locations. Hemispherical forgings produced through closed-die hammer forging were machined and electron beam welded to produce a spherical gas bottle. Duly welded gas bottle was subjected to standard aging treatment to achieve the required tensile strength. Aged gas bottle was inspected for dimensions and other stringent quality requirements using various nondestructive testing techniques. After inspection, gas bottle was subjected to pressure test for maximum expected operating pressure and proof pressure of 25 and 37.5 MPa, respectively. Strain gauges were bonded at different locations on the gas bottle to monitor the strains during the pressure test and correlated with the predicted values. The predicted strain matched well with the experimental strain confirming the design and structural integrity.

  17. Comparison of lesion detection and quantitation of tracer uptake between PET from a simultaneously acquiring whole-body PET/MR hybrid scanner and PET from PET/CT.

    PubMed

    Wiesmüller, Marco; Quick, Harald H; Navalpakkam, Bharath; Lell, Michael M; Uder, Michael; Ritt, Philipp; Schmidt, Daniela; Beck, Michael; Kuwert, Torsten; von Gall, Carl C

    2013-01-01

    PET/MR hybrid scanners have recently been introduced, but not yet validated. The aim of this study was to compare the PET components of a PET/CT hybrid system and of a simultaneous whole-body PET/MR hybrid system with regard to reproducibility of lesion detection and quantitation of tracer uptake. A total of 46 patients underwent a whole-body PET/CT scan 1 h after injection and an average of 88 min later a second scan using a hybrid PET/MR system. The radioactive tracers used were (18)F-deoxyglucose (FDG), (18)F-ethylcholine (FEC) and (68)Ga-DOTATATE (Ga-DOTATATE). The PET images from PET/CT (PET(CT)) and from PET/MR (PET(MR)) were analysed for tracer-positive lesions. Regional tracer uptake in these foci was quantified using volumes of interest, and maximal and average standardized uptake values (SUV(max) and SUV(avg), respectively) were calculated. Of the 46 patients, 43 were eligible for comparison and statistical analysis. All lesions except one identified by PET(CT) were identified by PET(MR) (99.2 %). In 38 patients (88.4 %), the same number of foci were identified by PET(CT) and by PET(MR). In four patients, more lesions were identified by PET(MR) than by PET(CT), in one patient PET(CT) revealed an additional focus compared to PET(MR). The mean SUV(max) and SUV(avg) of all lesions determined by PET(MR) were by 21 % and 11 % lower, respectively, than the values determined by PET(CT) (p < 0.05), and a strong correlation between these variables was identified (Spearman rho 0.835; p < 0.01). PET/MR showed equivalent performance in terms of qualitative lesion detection to PET/CT. The differences demonstrated in quantitation of tracer uptake between PET(CT) and PET(MR) were minor, but statistically significant. Nevertheless, a more detailed study of the quantitative accuracy of PET(MR) and the factors governing it is needed to ultimately assess its accuracy in measuring tissue tracer concentrations.

  18. Bacteriological quality of bottled drinking water versus municipal tap water in Dharan municipality, Nepal.

    PubMed

    Pant, Narayan Dutt; Poudyal, Nimesh; Bhattacharya, Shyamal Kumar

    2016-06-07

    Water-related diseases are of great concern in developing countries like Nepal. Every year, there are countless morbidity and mortality due to the consumption of unsafe drinking water. Recently, there have been increased uses of bottled drinking water in an assumption that the bottled water is safer than the tap water and its use will help to protect from water-related diseases. So, the main objective of this study was to analyze the bacteriological quality of bottled drinking water and that of municipal tap water. A total of 100 samples (76 tap water and 24 bottled water) were analyzed for bacteriological quality and pH. The methods used were spread plate method for total plate count (TPC) and membrane filter method for total coliform count (TCC), fecal coliform count (FCC), and fecal streptococcal count (FSC). pH meter was used for measuring pH. One hundred percent of the tap water samples and 87.5 % of the bottled water samples were found to be contaminated with heterotrophic bacteria. Of the tap water samples, 55.3 % were positive for total coliforms, compared with 25 % of the bottled water. No bottled water samples were positive for fecal coliforms and fecal streptococci, in contrast to 21.1 % and 14.5 % of the tap water samples being contaminated with fecal coliforms and fecal streptococci, respectively. One hundred percent of the tap water samples and 54.2 % of the bottled water samples had pH in the acceptable range. All of the municipal tap water samples and most of the bottled drinking water samples distributed in Dharan municipality were found to be contaminated with one or more than one type of indicator organisms. On the basis of our findings, we may conclude that comparatively, the bottled drinking water may have been safer (than tap water) to drink.

  19. Bottled Water Everywhere: Keeping it Safe

    MedlinePlus

    ... that taps an aquifer—layers of porous rock, sand, and earth that contain water—which is under ... it to be labeled as “purified water.” Ensuring Quality and Safety Federal quality standards for bottled water ...

  20. Bottle-feeding practices during early infancy and eating behaviors at 6 years of age.

    PubMed

    Li, Ruowei; Scanlon, Kelley S; May, Ashleigh; Rose, Chelsea; Birch, Leann

    2014-09-01

    Evidence suggests an association of breastfeeding with a maternal feeding style (MFS) that is less controlling than formula feeding, which, in turn, may improve a child's self-regulation of eating. This study examines associations of bottle-feeding practices during infancy with MFS and children's eating behavior (CEB) at 6 years old. We linked data from the Infant Feeding Practices Study II to the Year 6 Follow-Up, which include 8 MFS and CEB measures adapted from previous validated instruments. Bottle-feeding practices during the first 6 months estimated by using the Infant Feeding Practices Study II were bottle-feeding intensity (BFI), mother's encouragement of infant to finish milk in the bottle, and infant finishing all milk in the bottle. Adjusted odds ratios (aORs) for associations of bottle-feeding practices with MFS and CEB at 6 years old were calculated by using multivariable logistic regressions controlling for sociodemographic characteristics and other feeding practices (N = 1117). Frequent bottle emptying encouraged by mothers during infancy increased odds of mothers encouraging their child to eat all the food on their plate (aOR: 2.37; 95% confidence interval [CI]: 1.65-3.41] and making sure their child eats enough (aOR: 1.62; 95% CI: 1.14-2.31) and of children eating all the food on their plate at 6 years old (aOR: 2.01; 95% CI: 1.05-3.83). High BFI during early infancy also increased the odds of mothers being especially careful to ensure their 6-year-old eats enough. Bottle-feeding practices during infancy may have long-term effects on MFS and CEB. Frequent bottle emptying encouraged by mothers and/or high BFI during early infancy increased the likelihood of mothers pressuring their 6-year-old child to eat and children's low satiety responsiveness. Copyright © 2014 by the American Academy of Pediatrics.

  1. Ocular injuries from exploding glass-bottled Coca-Cola® drinks in Port Harcourt, Nigeria

    PubMed Central

    Pedro-Egbe, Chinyere Nnenne; Ejimadu, Chibuike Sydney; Nwachukwu, Henrietta

    2011-01-01

    Background: Eye injuries and subsequent loss of vision from the glass and caps of exploding pressurized bottled drinks have been well reported, and as a result most developed countries now use mainly plastic bottles. In Nigeria, however, most drinks are still sold in glass bottles and ocular injuries from this source are therefore not uncommon. Aim: To retrospectively analyze ocular injuries resulting from exploding glass-bottled Coca-Cola® and propose ways of eliminating such injuries in future. Setting: Eye Clinic, University of Port Harcourt Teaching Hospital, Port Harcourt, Nigeria. Materials and methods: The medical records of all cases of ocular injury that presented at the Eye Clinic of the University of Port Harcourt Teaching Hospital over a 5-year period (January 2006 to December 2010) were retrieved and relevant data including age, sex, occupation, events surrounding bottle explosion, and type of ocular injury sustained were extracted. Results: A total of 426 cases of ocular injuries was seen during the period under review. There were 335 (78.6%) males and 91 (21.4%) females. Six patients had ocular injury from exploding glass-bottled Coca-Cola®, giving an incidence of 1.4%. The presenting visual acuities (VA) were light perception (2 cases), counting fingers (2 cases), and 1 VA of 6/24 and 1 VA of 6/12. There were 4 (66.7%) cases of corneoscleral laceration with uveal prolapse and 1 case of total hyphema. Conclusion: Because pressurized glass-bottles can explode with normal handling, legislation to ban the use of glass containers for bottling carbonated drinks will go a long way to reducing ocular morbidity from this source. Plastic bottles should be introduced as an alternative. PMID:21629570

  2. Predicting water filter and bottled water use in Appalachia: a community-scale case study.

    PubMed

    Levêque, Jonas G; Burns, Robert C

    2017-06-01

    A questionnaire survey was conducted in order to assess residents' perceptions of water quality for drinking and recreational purposes in a mid-sized city in northcentral West Virginia. Two logistic regression analyses were conducted in order to investigate the factors that influence bottle use and filter use. Results show that 37% of respondents primarily use bottled water and that 58% use a household filter when drinking from the tap. Respondents with lower levels of environmental concern, education levels, and lower organoleptic perceptions were most likely to perceive health risks from tap water consumption, and were most likely to use bottled water. Income, age, and organoleptic perceptions were predictors of water filter use among respondents. Clean water for recreational purposes was not found to be significant with either of these models. Our results demonstrate that bottle use and filter use are explained differently. We argue that more education and better communication about local tap water quality would decrease the use of bottled water. We demonstrate that household filters could be used as an alternative to bottled water.

  3. [A norovirus-borne outbreak caused by contaminated bottled spring water in a school, Zhejiang province].

    PubMed

    Shen, Ji-chuan; Lin, Jun-fen; Gao, Jie; Yao, Wen-ting; Wen, Dong; Liu, Guang-tao; Han, Jian-kang; Ma, Hui-lai; Zhang, Li-jie; Zhu, Bao-ping

    2011-08-01

    To study a local hospital reported acute gastroenteritis in a boarding school on its source of infection, mode of transmission and risk factors of the infection. A suspected case was defined as who had developed diarrhea (≥ 3 times/day) or vomiting among teachers or students of the school, during April 19 - 30, 2010. A confirmed case was from a probable case plus tested positive for norovirus in stool specimens by using RT-PCR. Stool specimens of cases and environmental specimens were collected for laboratory diagnosis. In a case-control study, we compared exposures to sources of bottled water, consumption of bottled water, and hygienic habits of 220 probable or confirmed cases from April 21 - 23 in the peak of the outbreak, together with another 220 controls, with frequency-matched by school grade. 20.3% of the 1536 students but none of the teachers developed the disease. 98.6% of the cases (n = 217) and 85.5% (n = 188) of the controls had drunk bottled water in the classroom (OR(M-H) = 12.3, 95%CI: 3.7 - 40.9). 47.9% (n = 104) of the cases and 41.5% (n = 78) of the controls had drunk unboiled bottled water in classroom (OR(M-H) = 3.8, 95%CI: 1.5 - 9.6). 47.9% (n = 104) of the cases and 48.4% (n = 91) of the controls had drunk bottled mixed water (boiled and unboiled) in the classroom (OR(M-H) = 2.8, 95%CI: 1.1 - 7.0). Stool specimens from 3 cases and one bottle of uncovered bottled water in classroom showed positive of having norovirus genotype II. Coliforms was cultured much higher rates than standard deviations in the bottled water. The factory making the bottled water was not licensed or having strict disinfection facilities. Bottled spring water contaminated by norovirus was responsible for this outbreak.

  4. Lung PET scan

    MedlinePlus

    ... PET - chest; PET - lung; PET - tumor imaging; PET/CT - lung; Solitary pulmonary nodule - PET ... minutes. PET scans are performed along with a CT scan. This is because the combined information from ...

  5. Assessment of bisphenol A released from reusable plastic, aluminium and stainless steel water bottles.

    PubMed

    Cooper, James E; Kendig, Eric L; Belcher, Scott M

    2011-10-01

    Bisphenol A (BPA) is a ubiquitous high volume industrial chemical that is an estrogen and an environmental endocrine disrupting chemical. Bisphenol A is used extensively in the production of consumer goods, polycarbonate plastics, epoxy resins and coatings used to line metallic food and beverage cans. There is great concern regarding the possible harmful effects from exposures that result from BPA leaching into foods and beverages from packaging or storage containers. The objective of this study was to independently assess whether BPA contamination of water was occurring from different types of reusable drinking bottles marketed as alternatives to BPA-containing polycarbonate plastics. Using a sensitive and quantitative BPA-specific competitive enzyme-linked immunosorbent assay we evaluated whether BPA migrated into water stored in polycarbonate or copolyester plastic bottles, and different lined or unlined metallic reusable water bottles. At room temperature the concentration of BPA migrating from polycarbonate bottles ranged from 0.2 to 0.3 mg L⁻¹. Under identical conditions BPA migration from aluminium bottles lined with epoxy-based resins was variable depending on manufacturer ranging from 0.08 to 1.9 mg L⁻¹. Boiling water significantly increased migration of BPA from the epoxy lined bottles. No detectable BPA contamination was observed in water stored in bottles made from Tritan™ copolyester plastic, uncoated stainless steel, or aluminium lined with EcoCare™. The results from this study demonstrate that when used according to manufacturers' recommendations reusable water bottles constructed from "BPA-free" alternative materials are suitable for consumption of beverages free of BPA contamination. Copyright © 2011 Elsevier Ltd. All rights reserved.

  6. Laboratory Workflow Analysis of Culture of Periprosthetic Tissues in Blood Culture Bottles.

    PubMed

    Peel, Trisha N; Sedarski, John A; Dylla, Brenda L; Shannon, Samantha K; Amirahmadi, Fazlollaah; Hughes, John G; Cheng, Allen C; Patel, Robin

    2017-09-01

    Culture of periprosthetic tissue specimens in blood culture bottles is more sensitive than conventional techniques, but the impact on laboratory workflow has yet to be addressed. Herein, we examined the impact of culture of periprosthetic tissues in blood culture bottles on laboratory workflow and cost. The workflow was process mapped, decision tree models were constructed using probabilities of positive and negative cultures drawn from our published study (T. N. Peel, B. L. Dylla, J. G. Hughes, D. T. Lynch, K. E. Greenwood-Quaintance, A. C. Cheng, J. N. Mandrekar, and R. Patel, mBio 7:e01776-15, 2016, https://doi.org/10.1128/mBio.01776-15), and the processing times and resource costs from the laboratory staff time viewpoint were used to compare periprosthetic tissues culture processes using conventional techniques with culture in blood culture bottles. Sensitivity analysis was performed using various rates of positive cultures. Annualized labor savings were estimated based on salary costs from the U.S. Labor Bureau for Laboratory staff. The model demonstrated a 60.1% reduction in mean total staff time with the adoption of tissue inoculation into blood culture bottles compared to conventional techniques (mean ± standard deviation, 30.7 ± 27.6 versus 77.0 ± 35.3 h per month, respectively; P < 0.001). The estimated annualized labor cost savings of culture using blood culture bottles was $10,876.83 (±$337.16). Sensitivity analysis was performed using various rates of culture positivity (5 to 50%). Culture in blood culture bottles was cost-effective, based on the estimated labor cost savings of $2,132.71 for each percent increase in test accuracy. In conclusion, culture of periprosthetic tissue in blood culture bottles is not only more accurate than but is also cost-saving compared to conventional culture methods. Copyright © 2017 American Society for Microbiology.

  7. Transoceanic drift and the domestication of African bottle gourds in the Americas.

    PubMed

    Kistler, Logan; Montenegro, Alvaro; Smith, Bruce D; Gifford, John A; Green, Richard E; Newsom, Lee A; Shapiro, Beth

    2014-02-25

    Bottle gourd (Lagenaria siceraria) was one of the first domesticated plants, and the only one with a global distribution during pre-Columbian times. Although native to Africa, bottle gourd was in use by humans in east Asia, possibly as early as 11,000 y ago (BP) and in the Americas by 10,000 BP. Despite its utilitarian importance to diverse human populations, it remains unresolved how the bottle gourd came to be so widely distributed, and in particular how and when it arrived in the New World. A previous study using ancient DNA concluded that Paleoindians transported already domesticated gourds to the Americas from Asia when colonizing the New World [Erickson et al. (2005) Proc Natl Acad Sci USA 102(51):18315-18320]. However, this scenario requires the propagation of tropical-adapted bottle gourds across the Arctic. Here, we isolate 86,000 base pairs of plastid DNA from a geographically broad sample of archaeological and living bottle gourds. In contrast to the earlier results, we find that all pre-Columbian bottle gourds are most closely related to African gourds, not Asian gourds. Ocean-current drift modeling shows that wild African gourds could have simply floated across the Atlantic during the Late Pleistocene. Once they arrived in the New World, naturalized gourd populations likely became established in the Neotropics via dispersal by megafaunal mammals. These wild populations were domesticated in several distinct New World locales, most likely near established centers of food crop domestication.

  8. Transoceanic drift and the domestication of African bottle gourds in the Americas

    PubMed Central

    Kistler, Logan; Montenegro, Álvaro; Smith, Bruce D.; Gifford, John A.; Green, Richard E.; Newsom, Lee A.; Shapiro, Beth

    2014-01-01

    Bottle gourd (Lagenaria siceraria) was one of the first domesticated plants, and the only one with a global distribution during pre-Columbian times. Although native to Africa, bottle gourd was in use by humans in east Asia, possibly as early as 11,000 y ago (BP) and in the Americas by 10,000 BP. Despite its utilitarian importance to diverse human populations, it remains unresolved how the bottle gourd came to be so widely distributed, and in particular how and when it arrived in the New World. A previous study using ancient DNA concluded that Paleoindians transported already domesticated gourds to the Americas from Asia when colonizing the New World [Erickson et al. (2005) Proc Natl Acad Sci USA 102(51):18315–18320]. However, this scenario requires the propagation of tropical-adapted bottle gourds across the Arctic. Here, we isolate 86,000 base pairs of plastid DNA from a geographically broad sample of archaeological and living bottle gourds. In contrast to the earlier results, we find that all pre-Columbian bottle gourds are most closely related to African gourds, not Asian gourds. Ocean-current drift modeling shows that wild African gourds could have simply floated across the Atlantic during the Late Pleistocene. Once they arrived in the New World, naturalized gourd populations likely became established in the Neotropics via dispersal by megafaunal mammals. These wild populations were domesticated in several distinct New World locales, most likely near established centers of food crop domestication. PMID:24516122

  9. Variations on the "Whoosh" Bottle Alcohol Explosion Demonstration Including Safety Notes.

    ERIC Educational Resources Information Center

    Fortman, John J.; Rush, Andrea C.; Stamper, Jennifer E.

    1999-01-01

    Presents several variations on a demonstration in which alcohol vapors are combusted in large small-necked bottles, causing a blue flame to shoot from the bottle's mouth. Describes variations with different pure alcohols, temperature, alcohol/water solution concentration, oxygen concentration, type of container, and the addition of salt for color.…

  10. White HDPE bottles as source of serious contamination of water samples with Ba and Zn.

    PubMed

    Reimann, Clemens; Grimstvedt, Andreas; Frengstad, Bjørn; Finne, Tor Erik

    2007-03-15

    During a recent study of surface water quality factory new white high-density polyethylene (HDPE) bottles were used for collecting the water samples. According to the established field protocol of the Geological Survey of Norway the bottles were twice carefully rinsed with water in the field prior to sampling. Several blank samples using milli-Q (ELGA) water (>18.2 MOmega) were also prepared. On checking the analytical results the blanks returned values of Ag, Ba, Sr, V, Zn and Zr. For Ba and Zn the values (c. 300 microg/l and 95 microg/l) were about 10 times above the concentrations that can be expected in natural waters. A laboratory test of the bottles demonstrated that the bottles contaminate the samples with significant amounts of Ba and Zn and some Sr. Simple acid washing of the bottles prior to use did not solve the contamination problem for Ba and Zn. The results suggest that there may exist "clean" and "dirty" HDPE bottles depending on manufacturer/production process. When collecting water samples it is mandatory to check bottles regularly as a possible source of contamination.

  11. 27 CFR 19.204 - Alternation of distilled spirits plant and taxpaid wine bottling house premises.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... spirits plant and taxpaid wine bottling house premises. 19.204 Section 19.204 Alcohol, Tobacco Products... distilled spirits plant and taxpaid wine bottling house premises. (a) General. A proprietor of a distilled spirits plant operating a contiguous taxpaid wine bottling house desiring to alternate the use of each...

  12. From Blogs to Bottle Caps

    ERIC Educational Resources Information Center

    Edinger, Ted

    2012-01-01

    There is a wonderful community of art educators connecting a once-isolated profession through blogging. Art educators around the world are sharing ideas and communicating with their peers through this amazing resource. In this article, the author describes the bottle cap mural at Tulip Grove Elementary School which was inspired by this exchange of…

  13. FLUORIDE CONTENT OF COMMERCIALLY AVAILABLE BOTTLED DRINKING WATER IN BANGKOK, THAILAND.

    PubMed

    Rirattanapong, Praphasri; Rirattanapong, Opas

    2016-09-01

    The use of bottled drinking water may be a source of fluoride and could be a risk factor for fluorosis among infants and young children. The aim of this study was to evaluate the fluoride content of commercially available bottled drinking water in Bangkok, Thailand. Forty-five water samples (15 samples of plain water and 30 samples of mineral water) were purchased from several supermarkets in Bangkok, Thailand. Three bottles of each water sample were purchased, and the fluoride content of each sample was measured twice using a combination fluoride-ion selective electrode. The average reading for each sample was then calculated. Data were analyzed by descriptive statistics. Differences between mineral and plain water samples were determined by Student’s t-test. The mean (±SD) fluoride content for all the water samples was 0.17 (±0.17) mg F/l (range: 0.01-0.89 mg F/l). Six brands (13%) tested stated the fluoride content on the label. The actual fluoride content in each of their brands varied little from the label. Eight samples (18%) had a fluoride content >0.3 mg F/l and two samples (4%) had a fluoride content >0.6 mg F/l. The mean mineral water fluoride concentration was significantly higher than the mean fluoride concentration of plain water (p=0.001). We found commercially sold bottled drinking water in Bangkok, Thailand contained varying concentrations of fluoride; some with high concentrations of fluoride. Health professions need to be aware this varying fluoride content of bottled drinking water and educate the parents of infants and small children about this when prescribing fluoride supplements. Consideration should be made to have fluoride content put on the label of bottled water especially among brands with a content >0.3 mg F/l.

  14. Stochastic Optimization in The Power Management of Bottled Water Production Planning

    NASA Astrophysics Data System (ADS)

    Antoro, Budi; Nababan, Esther; Mawengkang, Herman

    2018-01-01

    This paper review a model developed to minimize production costs on bottled water production planning through stochastic optimization. As we know, that planning a management means to achieve the goal that have been applied, since each management level in the organization need a planning activities. The built models is a two-stage stochastic models that aims to minimize the cost on production of bottled water by observing that during the production process, neither interfernce nor vice versa occurs. The models were develop to minimaze production cost, assuming the availability of packing raw materials used considered to meet for each kind of bottles. The minimum cost for each kind production of bottled water are expressed in the expectation of each production with a scenario probability. The probability of uncertainly is a representation of the number of productions and the timing of power supply interruption. This is to ensure that the number of interruption that occur does not exceed the limit of the contract agreement that has been made by the company with power suppliers.

  15. Development of PET/MRI with insertable PET for simultaneous PET and MR imaging of human brain.

    PubMed

    Jung, Jin Ho; Choi, Yong; Jung, Jiwoong; Kim, Sangsu; Lim, Hyun Keong; Im, Ki Chun; Oh, Chang Hyun; Park, Hyun-wook; Kim, Kyung Min; Kim, Jong Guk

    2015-05-01

    The purpose of this study was to develop a dual-modality positron emission tomography (PET)/magnetic resonance imaging (MRI) with insertable PET for simultaneous PET and MR imaging of the human brain. The PET detector block was composed of a 4 × 4 matrix of detector modules, each consisting of a 4 × 4 array LYSO coupled to a 4 × 4 Geiger-mode avalanche photodiode (GAPD) array. The PET insert consisted of 18 detector blocks, circularly mounted on a custom-made plastic base to form a ring with an inner diameter of 390 mm and axial length of 60 mm. The PET gantry was shielded with gold-plated conductive fabric tapes with a thickness of 0.1 mm. The charge signals of PET detector transferred via 4 m long flat cables were fed into the position decoder circuit. The flat cables were shielded with a mesh-type aluminum sheet with a thickness of 0.24 mm. The position decoder circuit and field programmable gate array-embedded DAQ modules were enclosed in an aluminum box with a thickness of 10 mm and located at the rear of the MR bore inside the MRI room. A 3-T human MRI system with a Larmor frequency of 123.7 MHz and inner bore diameter of 60 cm was used as the PET/MRI hybrid system. A custom-made radio frequency (RF) coil with an inner diameter of 25 cm was fabricated. The PET was positioned between gradient and the RF coils. PET performance was measured outside and inside the MRI scanner using echo planar imaging, spin echo, turbo spin echo, and gradient echo sequences. MRI performance was also evaluated with and without the PET insert. The stability of the newly developed PET insert was evaluated and simultaneous PET and MR images of a brain phantom were acquired. No significant degradation of the PET performance caused by MR was observed when the PET was operated using various MR imaging sequences. The signal-to-noise ratio of MR images was slightly degraded due to the PET insert installed inside the MR bore while the homogeneity was maintained. The change of gain of

  16. Development of PET/MRI with insertable PET for simultaneous PET and MR imaging of human brain

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jung, Jin Ho; Choi, Yong, E-mail: ychoi.image@gmail.com; Jung, Jiwoong

    2015-05-15

    Purpose: The purpose of this study was to develop a dual-modality positron emission tomography (PET)/magnetic resonance imaging (MRI) with insertable PET for simultaneous PET and MR imaging of the human brain. Methods: The PET detector block was composed of a 4 × 4 matrix of detector modules, each consisting of a 4 × 4 array LYSO coupled to a 4 × 4 Geiger-mode avalanche photodiode (GAPD) array. The PET insert consisted of 18 detector blocks, circularly mounted on a custom-made plastic base to form a ring with an inner diameter of 390 mm and axial length of 60 mm. Themore » PET gantry was shielded with gold-plated conductive fabric tapes with a thickness of 0.1 mm. The charge signals of PET detector transferred via 4 m long flat cables were fed into the position decoder circuit. The flat cables were shielded with a mesh-type aluminum sheet with a thickness of 0.24 mm. The position decoder circuit and field programmable gate array-embedded DAQ modules were enclosed in an aluminum box with a thickness of 10 mm and located at the rear of the MR bore inside the MRI room. A 3-T human MRI system with a Larmor frequency of 123.7 MHz and inner bore diameter of 60 cm was used as the PET/MRI hybrid system. A custom-made radio frequency (RF) coil with an inner diameter of 25 cm was fabricated. The PET was positioned between gradient and the RF coils. PET performance was measured outside and inside the MRI scanner using echo planar imaging, spin echo, turbo spin echo, and gradient echo sequences. MRI performance was also evaluated with and without the PET insert. The stability of the newly developed PET insert was evaluated and simultaneous PET and MR images of a brain phantom were acquired. Results: No significant degradation of the PET performance caused by MR was observed when the PET was operated using various MR imaging sequences. The signal-to-noise ratio of MR images was slightly degraded due to the PET insert installed inside the MR bore while the homogeneity was

  17. Explicit Solvent Simulations of Friction between Brush Layers of Charged and Neutral Bottle-Brush Macromolecules

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carrillo, Jan-Michael; Brown, W Michael; Dobrynin, Andrey

    2012-01-01

    We study friction between charged and neutral brush layers of bottle-brush macromolecules using molecular dynamics simulations. In our simulations the solvent molecules were treated explicitly. The deformation of the bottle-brush macromolecules under the shear were studied as a function of the substrate separation and shear stress. For charged bottle-brush layers we study effect of the added salt on the brush lubricating properties to elucidate factors responsible for energy dissipation in charged and neutral brush systems. Our simulations have shown that for both charged and neutral brush systems the main deformation mode of the bottle-brush macromolecule is associated with the backbonemore » deformation. This deformation mode manifests itself in the backbone deformation ratio, , and shear viscosity, , to be universal functions of the Weissenberg number W. The value of the friction coefficient, , and viscosity, , are larger for the charged bottle-brush coatings in comparison with those for neutral brushes at the same separation distance, D, between substrates. The additional energy dissipation generated by brush sliding in charged bottle-brush systems is due to electrostatic coupling between bottle-brush and counterion motion. This coupling weakens as salt concentration, cs, increases resulting in values of the viscosity, , and friction coefficient, , approaching corresponding values obtained for neutral brush systems.« less

  18. Grip force and force sharing in two different manipulation tasks with bottles.

    PubMed

    Cepriá-Bernal, Javier; Pérez-González, Antonio; Mora, Marta C; Sancho-Bru, Joaquín L

    2017-07-01

    Grip force and force sharing during two activities of daily living were analysed experimentally in 10 right-handed subjects. Four different bottles, filled to two different levels, were manipulated for two tasks: transporting and pouring. Each test subject's hand was instrumented with eight thin wearable force sensors. The grip force and force sharing were significantly different for each bottle model. Increasing the filling level resulted in an increase in grip force, but the ratio of grip force to load force was higher for lighter loads. The task influenced the force sharing but not the mean grip force. The contributions of the thumb and ring finger were higher in the pouring task, whereas the contributions of the palm and the index finger were higher in the transport task. Mean force sharing among fingers was 30% for index, 29% for middle, 22% for ring and 19% for little finger. Practitioner Summary: We analysed grip force and force sharing in two manipulation tasks with bottles: transporting and pouring. The objective was to understand the effects of the bottle features, filling level and task on the contribution of different areas of the hand to the grip force. Force sharing was different for each task and the bottles features affected to both grip force and force sharing.

  19. Fluoride concentration in community water and bottled drinking water: a dilemma today.

    PubMed

    Dhingra, S; Marya, C M; Jnaneswar, A; Kumar, H

    2013-01-01

    Because of the potential for contamination of municipal water supplies, people appear to be turning to alternative sources for their pure drinking water. The present study analyzed the fluoride concentration in community water and bottled drinking water sold in Faridabad city. A comparative evaluation of fluoride content in community water supply and bottled drinking water was done using ion-selective electrode method. The community water samples were collected from six different areas (i.e. north zone, south zone, east zone, west zone and central zone) in the city from public health water supply taps while bottled drinking water samples were randomly picked from grocery shops or supermarkets. The fluoride concentration in the community water supply in this study ranges from 0.11 to 0.26 mg/L with mean fluoride concentration of 0.17 mg/L. The mean concentration of fluoride in bottled drinking water was 0.06 mg/L. The differences observed between mean of two water samples was statistically significant. The results obtained from the present study clearly state that the fluoride concentration was insufficient in community water supply from all the areas and also was deficient in bottled drinking water sold in Faridabad city. So, Alternative sources of fluorides should be supplemented for optimal dental benefits from the use of fluoride.

  20. Low-cost floating emergence net and bottle trap: Comparison of two designs

    USGS Publications Warehouse

    Cadmus, Pete; Pomeranz, Justin; Kraus, Johanna M.

    2016-01-01

    Sampling emergent aquatic insects is of interest to many freshwater ecologists. Many quantitative emergence traps require the use of aspiration for collection. However, aspiration is infeasible in studies with large amounts of replication that is often required in large biomonitoring projects. We designed an economic, collapsible pyramid-shaped floating emergence trap with an external collection bottle that avoids the need for aspiration. This design was compared experimentally to a design of similar dimensions that relied on aspiration to ensure comparable results. The pyramid-shaped design captured twice as many total emerging insects. When a preservative was used in bottle collectors, >95% of the emergent abundance was collected in the bottle. When no preservative was used, >81% of the total insects were collected from the bottle. In addition to capturing fewer emergent insects, the traps that required aspiration took significantly longer to sample. Large studies and studies sampling remote locations could benefit from the economical construction, speed of sampling, and capture efficiency.

  1. The bacteriological quality of different brands of bottled water available to consumers in Ile-Ife, south-western Nigeria.

    PubMed

    Igbeneghu, Oluwatoyin A; Lamikanra, Adebayo

    2014-11-28

    The upsurge in the demand for bottled water has prompted the interest of many manufacturers in the production of bottled water and very many water bottling companies are therefore involved in its production. These range from large scale multinational companies to medium scale business enterprises, institutional and government business investment companies as well as small scale entrepreneurs. There is however little information on the comparative quality of bottled water brands produced by different classes of water bottling companies in Nigeria. This study was undertaken to determine the bacteriological quality of brands of bottled water available to consumers in Ile-Ife. Forty-three samples of bottled water comprising of three batches each of thirteen bottled water brands and two batches of two brands were purchased and analyzed for total bacterial count, presence of coliform and the presence of other bacterial indicators of drinking water quality. Only 67.4% of the water samples representing the products of 10 companies or 66.7% of the brands had heterotrophic counts within the acceptable limits. Coliforms present in 100 ml of water were detected in 26.7% of the bottled water brands. Other indicator organisms detected included Staphylococci isolated from 27.9% of the samples (33.3% of the brands) and specifically Staphylococcus aureus found in four brands constituting 14% of the samples. Pseudomonas strains were consistently detected in consecutive batches of three brands of the water samples. Bottled water samples produced by the large scale multinational producers were of acceptable bacteriological quality unlike those produced by most small companies. There is need for a greater control of water bottling processes carried out by commercial bottled water producers in Nigeria.

  2. Safety of Bottled Water Beverages Including Flavored Water and Nutrient-Added Water Beverages

    MedlinePlus

    ... verifies that the plant's product water and operational water supply are obtained from an approved source; inspects washing and sanitizing procedures; inspects bottling operations; and determines whether ... water and product water for contaminants. Americans like bottled ...

  3. Incorporating waste into an experimental school prototype: lessons regarding materials reclamation opportunities.

    PubMed

    Yeap, Kong Seng; Mohd Yaacob, Naziaty; Rao, Sreenivasaiah Purushothama; Hashim, Nor Rasidah

    2012-12-01

    This article presents lessons learned from a design project that explored the possibility of incorporating waste into the design of a school prototype. The authors worked with professional architects, a waste artist, environmental scientists and local waste operators to uncover new uses and applications for discarded items. As a result, bottles, aluminium cans, reclaimed doors, crushed concrete and second-hand bricks, etc. were identified, explored and integrated into the architectural design. This article serves as a catalyst that advocates the use of reclaimed materials in the field of design and planning. In particular, it highlights the challenges and issues that need to be addressed in carrying out design work with waste. Designers and practitioners interested in minimizing waste generation by proposing the use of reclaimed materials will find this article useful.

  4. Treatment techniques for the recycling of bottle washing water in the soft drinks industry.

    PubMed

    Ramirez Camperos, E; Mijaylova Nacheva, P; Diaz Tapia, E

    2004-01-01

    The soft drink production is an important sector in the manufacturing industry of Mexico. Water is the main source in the production of soft drinks. Wastewater from bottle washing is almost 50% of the total wastewater generated by this industry. In order to reduce the consumption of water, the water of the last bottle rinse can be reused in to the bottle pre-rinse and pre-washing cycles. This work presents the characterization of the final bottle washing rinse discharge and the treatability study for the most appropriate treatment system for recycling. Average characteristics of the final bottle wash rinse were as follows: Turbidity 40.46 NTU, COD 47.7 mg/L, TSS 56 mg/L, TS 693.6 mg/L, electrical conductivity 1,194 microS/cm. The results of the treatability tests showed that the final rinse water can be used in the pre-rinse and pre-washing after removing the totality of the suspended solids, 80% of the COD and 75% of the dissolved solids. This can be done using the following treatment systems: filtration-adsorption-reverse osmosis, or filtration-adsorption-ion exchange. The installation of these treatment techniques in the soft drink industry would decrease bottle washing water consumption by 50%.

  5. Frequency of use controls chemical leaching from drinking-water containers subject to disinfection.

    PubMed

    Andra, Syam S; Makris, Konstantinos C; Shine, James P

    2011-12-15

    Microbial-, and chemical-based burden of disease associated with lack of access to safe water continues to primarily impact developing countries. Cost-effective health risk-mitigating measures, such as of solar disinfection applied to microbial-contaminated water stored in plastic bottles have been increasingly tested in developing countries adversely impacted by epidemic water-borne diseases. Public health concerns associated with chemical leaching from water packaging materials led us to investigate the magnitude and variability of antimony (Sb) and bromine (Br) leaching from reused plastic containers (polyethylene terephthalate, PET; and polycarbonate, PC) subject to UV and/or temperature-driven disinfection. The overall objective of this study was to determine the main and interactive effects of temperature, UV exposure duration, and frequency of bottle reuse on the extent of leaching of Sb and Br from plastic bottles into water. Regardless of UV exposure duration, frequency of reuse (up to 27 times) was the major factor that linearly increased Sb leaching from PET bottles at all temperatures tested (13-47 °C). Leached Sb concentrations (∼360 ng L(-1)) from the highly reused (27 times) PET bottles (minimal Sb leaching from PC bottles, <15 ng L(-1)) did not pose a serious risk to human health according to current daily Sb acceptable intake estimates. Leached Br concentrations from both PET and PC containers (up to ∼15 μg L(-1)) did not pose a consumer health risk either, however, no acceptable daily dose estimates exist for oral ingestion of organo-brominated, or other plasticizers/additives compounds if they were to be found in bottled water at much lower concentrations. Additional research on potential leaching of organic chemicals from water packaging materials is deemed necessary under relevant environmental conditions. Copyright © 2011 Elsevier Ltd. All rights reserved.

  6. NEMA NU 4-2008 Performance Measurements of Two Commercial Small-Animal PET Scanners: ClearPET and rPET-1

    NASA Astrophysics Data System (ADS)

    Canadas, Mario; Embid, Miguel; Lage, Eduardo; Desco, Manuel; Vaquero, Juan José; Perez, José Manuel

    2011-02-01

    In this work, we compare two commercial positron emission tomography (PET) scanners installed at CIEMAT (Madrid, Spain): the ClearPET and the rPET-1. These systems have significant geometrical differences, such as the axial field of view (110 mm on ClearPET versus 45.6 mm on rPET-1), the configuration of the detectors (whole ring on ClearPET versus one pair of planar blocks on rPET-1) and the use of an axial shift between ClearPET detector modules. We used an assessment procedure that fulfilled the recommendations of the National Electrical Manufacturers Association (NEMA) NU 4-2008 standard. The methodology includes studies of spatial resolution, sensitivity, scatter fraction, count losses and image quality. Our experiments showed a central spatial resolution of 1.5 mm (transaxial), 3.2 mm (axial) for the ClearPET and 1.5 mm (transaxial), 1.6 mm (axial) for the rPET-1, with a small variation across the transverse axis on both scanners ( 1 mm). The absolute sensitivity at the centre of the field of view was 4.7% for the ClearPET and 1.0% for the rPET-1. The peak noise equivalent counting rate for the mouse-sized phantom was 73.4 kcps reached at 0.51 MBq/mL on the ClearPET and 29.2 kcps at 1.35 MBq/mL on the rPET-1. The recovery coefficients measured using the image quality phantom ranged from 0.11 to 0.89 on the ClearPET and from 0.14 to 0.81 on the rPET-1. The overall performance shows that both the ClearPET and the rPET-1 systems are very suitable for preclinical research and imaging of small animals.

  7. Migration of bisphenol A from polycarbonate baby and water bottles into water under severe conditions.

    PubMed

    Cao, Xu-Liang; Corriveau, Jeannette

    2008-08-13

    The isotope dilution headspace solid-phase microextraction and gas chromatography-mass spectrometry method for bisphenol A (BPA) developed previously was used successfully in a BPA migration study at 70 degrees C of polycarbonate baby and reusable water bottles recently sold in Canada by using the whole bottles instead of pieces cut from the bottles. Migration of BPA from the PC bottles heated at 70 degrees C was found to increase over the time in the quadratic equations. Migration levels of BPA in water varied from 228 to 521 microg L (-1) or from 0.26 to 0.90 microg cm (-2) after being heated at 70 degrees C for 6 days. The average migration rates of BPA from the PC bottles into water at 70 degrees C ranged from 1.84 to 4.83 ng cm (-2) h (-1).

  8. [Principles of PET].

    PubMed

    Beuthien-Baumann, B

    2018-05-01

    Positron emission tomography (PET) is a procedure in nuclear medicine, which is applied predominantly in oncological diagnostics. In the form of modern hybrid machines, such as PET computed tomography (PET/CT) and PET magnetic resonance imaging (PET/MRI) it has found wide acceptance and availability. The PET procedure is more than just another imaging technique, but a functional method with the capability for quantification in addition to the distribution pattern of the radiopharmaceutical, the results of which are used for therapeutic decisions. A profound knowledge of the principles of PET including the correct indications, patient preparation, and possible artifacts is mandatory for the correct interpretation of PET results.

  9. Evaluation of the effectiveness of an intravenous line and fluid bottle fixation design.

    PubMed

    Chiou, Piao-Yi; Chien, Chih-Yin; Shiu, Ting-Ru; Lin, Pei-Jiun; Lin, Wan-Yu; Jiang, Yi-Rung

    2015-01-01

    It's important to improve the stability of intravenous (IV) lines and bottles during patient activity and nursing care. We developed an intravenous line and fluid bottle fixation design (ILFBFD) which includes a bottle retaining clip and line fixation kit. We randomly assigned 60 participants each to the experimental and control groups. Participants were asked to push an IV stand without and with ILFBFD 11 meters on uneven pavement and a sloping floor. The distance the IV bottle moved was recorded. Self-administered questionnaires were used to collect the opinions of the participants. Use of ILFBFD, resulted in less movement in the anteroposterior and left/right directions (differences of 46.98 cm2, t= 12.80, p < 0.000 and 39.24 cm2, t= 8.01, p< 0.000, respectively) compared with not using ILFBFD. The average scores for bottle movement when participants walked on a flat floor, uneven pavement and sloping floor, IV line tangling and dropping, and organization of Liv lines were significantly better in those using than not using ILFBFD. The results can be used in clinical practice to reduce knotting of IV lines, and to enhance the safety and quality of patient care.

  10. Managing Dog Waste: Campaign Insights from the Health Belief Model

    ERIC Educational Resources Information Center

    Typhina, Eli; Yan, Changmin

    2014-01-01

    Aiming to help municipalities develop effective education and outreach campaigns to reduce stormwater pollutants, such as pet waste, this study applied the Health Belief Model (HBM) to identify perceptions of dog waste and corresponding collection behaviors from dog owners living in a small U.S. city. Results of 455 online survey responses…

  11. Assessment of Bisphenol A Released from Reusable Plastic, Aluminium and Stainless Steel Water Bottles

    PubMed Central

    Cooper, James E.; Kendig, Eric L.; Belcher, Scott M.

    2011-01-01

    Bisphenol A(BPA) is a ubiquitous high volume industrial chemical that is an estrogen and an environmental endocrine disrupting chemical. Bisphenol A is used extensively in the production of consumer goods, polycarbonate plastics, epoxy resins, coating used to line metallic food and beverage cans, and other products.There is great concern regarding the possible harmful effects from exposures that result from BPAleaching into foods and beverages from packaging or storage containers. The objective of this study was to independently assesswhether BPA contamination of water was occurring from different types of reusable drinking bottlesmarketed as alternatives to BPA-containing polycarbonate plastics. Using a sensitive and quantitative BPA-specific competitive enzyme-linked immunosorbent assaywe evaluated whether BPA migrated into water stored inpolycarbonateor copolyester plastic bottles, and different lined or unlined metallic reusable water bottles. At room temperature the concentration of BPA migrating from polycarbonate bottles ranged from 0.2–0.3 mg/L. Under identical conditions BPA migration from aluminium bottles lined with epoxy-based resins was variable depending on manufacturer ranging from 0.08 to 1.9 mg/L.Boiling water significantly increased migration of BPA from the epoxy lined bottles. No detectable BPA contamination was observed in water stored in bottles made from Tritan™ copolyester plastic, uncoated stainless steel, or aluminium lined with EcoCare™. The results from this study demonstrate that when used according to manufactures’ recommendations reusable water bottles constructed from “BPA-free” alternative materials are suitable for consumption of beverages free of BPA contamination. PMID:21741673

  12. Effect of production phase on bottle-fermented sparkling wine quality.

    PubMed

    Kemp, Belinda; Alexandre, Hervé; Robillard, Bertrand; Marchal, Richard

    2015-01-14

    This review analyzes bottle-fermented sparkling wine research at each stage of production by evaluating existing knowledge to identify areas that require future investigation. With the growing importance of enological investigation being focused on the needs of the wine production industry, this review examines current research at each stage of bottle-fermented sparkling wine production. Production phases analyzed in this review include pressing, juice adjustments, malolactic fermentation (MLF), stabilization, clarification, tirage, lees aging, disgorging, and dosage. The aim of this review is to identify enological factors that affect bottle-fermented sparkling wine quality, predominantly aroma, flavor, and foaming quality. Future research topics identified include regional specific varieties, plant-based products from vines, grapes, and yeast that can be used in sparkling wine production, gushing at disgorging, and methods to increase the rate of yeast autolysis. An internationally accepted sensory analysis method specifically designed for sparkling wine is required.

  13. Hydrothermal Gasification for Waste to Energy

    NASA Astrophysics Data System (ADS)

    Epps, Brenden; Laser, Mark; Choo, Yeunun

    2014-11-01

    Hydrothermal gasification is a promising technology for harvesting energy from waste streams. Applications range from straightforward waste-to-energy conversion (e.g. municipal waste processing, industrial waste processing), to water purification (e.g. oil spill cleanup, wastewater treatment), to biofuel energy systems (e.g. using algae as feedstock). Products of the gasification process are electricity, bottled syngas (H2 + CO), sequestered CO2, clean water, and inorganic solids; further chemical reactions can be used to create biofuels such as ethanol and biodiesel. We present a comparison of gasification system architectures, focusing on efficiency and economic performance metrics. Various system architectures are modeled computationally, using a model developed by the coauthors. The physical model tracks the mass of each chemical species, as well as energy conversions and transfers throughout the gasification process. The generic system model includes the feedstock, gasification reactor, heat recovery system, pressure reducing mechanical expanders, and electricity generation system. Sensitivity analysis of system performance to various process parameters is presented. A discussion of the key technological barriers and necessary innovations is also presented.

  14. Professor Pet.

    ERIC Educational Resources Information Center

    Pet Information Bureau, New York, NY.

    This manual outlines ways in which observation and care of classroom pet animals may be used to enrich the education of elementary school children. Part one deals with the benefits of having pets in the classroom. Part two illustrates ways in which pets can serve as valuable teaching tools and gives examples of lessons in which the use of pets can…

  15. Perceived impact of smaller compared with larger-sized bottles of sugar-sweetened beverages on consumption: A qualitative analysis.

    PubMed

    Mantzari, Eleni; Hollands, Gareth J; Pechey, Rachel; Jebb, Susan; Marteau, Theresa M

    2018-01-01

    Sugar-sweetened beverage (SSB) consumption increases obesity risk and is linked to adverse health consequences. Large packages increase food consumption, but most evidence comes from studies comparing larger with standard packages, resulting in uncertainty regarding the impact of smaller packages. There is also little research on beverages. This qualitative study explores the experiences of consuming cola from smaller compared with larger bottles, to inform intervention strategies. Sixteen households in Cambridge, England, participating in a feasibility study assessing the impact of bottle size on in-home SSB consumption, received a set amount of cola each week for four weeks in one of four bottle sizes: 1500 ml, 1000 ml, 500 ml, or 250 ml, in random order. At the study end, household representatives were interviewed about their experiences of using each bottle, including perceptions of i) consumption level; ii) consumption-related behaviours; and iii) factors affecting consumption. Interviews were semi-structured and data analysed using the Framework approach. The present analysis focuses specifically on experiences relating to use of the smaller bottles. The smallest bottles were described as increasing drinking occasion frequency and encouraging consumption of numerous bottles in succession. Factors described as facilitating their consumption were: i) convenience and portability; ii) greater numbers of bottles available, which hindered consumption monitoring and control; iii) perceived insufficient quantity per bottle; and iv) positive attitudes. In a minority of cases the smallest bottles were perceived to have reduced consumption, but this was related to practical issues with the bottles that resulted in dislike. The perception of greater consumption and qualitative reports of drinking habits associated with the smallest bottles raise the possibility that the 'portion size effect' has a lower threshold, beyond which smaller portions and packages may

  16. Alternative Fuels Data Center: Coca-Cola Bottling Co. Brings Hybrids to New

    Science.gov Websites

    as a great example of a viable clean transportation option for similar fleets. " Rebecca Otte commitment to a more sustainable community and serves as a great example of a viable clean transportation , individual bottling companies now operate these vehicles. For example, Coca-Cola Bottling Company United

  17. Quality comparison of tap water vs. bottled water in the industrial city of Yanbu (Saudi Arabia).

    PubMed

    Ahmad, Maqbool; Bajahlan, Ahmad S

    2009-12-01

    This study was conducted to compare the quality of bottled water with potabilized desalinated tap water. Fourteen brands of local and imported bottled water samples were collected from the local market and analyzed for physicochemical parameters in the Royal Commission Environmental Laboratory. Results were compared with 5-year continuous monitoring data of tap water from different locations in Madinat Yanbu Al-Sinaiyah (MYAS) including storage tanks of desalination plant. Results show that there was no significant difference in the quality of tap water and bottled water. Bacteriological test was never found positive in the 5-year data in tap water. Similarly, physicochemical analysis shows the persistent quality of tap water. Based on hardness analysis, bottled and tap water are categorized as soft water. Trihalomethanes (THMs) study also indicates that traces of disinfection by products (DBPs) are present in both tap and bottled water and are much less than the World Health Organization and Environmental Protection Agency maximum permissible limits. It is also important to note that the tap water distribution network in MAYS is a high-pressure recirculation network and there is no chance to grow bacteria in stagnant water in pipe lines or houses. Recently, the Royal Commission has replaced the whole drinking water network, which was made of asbestos-cemented pipes with glass-reinforced plastic (GRP) pipes, to avoid any asbestos contaminations. Based on these results, it is concluded that drinking water distributed in the city is of very good and persistent quality, comparable with bottled water. Continuous monitoring also guarantees the safe drinking water to the community. Hence, it is the responsibility of the Royal Commission to encourage the peoples in the city to drink tap water as it is as good as bottled water even better than some of the brands and is monitored regularly. It is also much cheaper compared to bottled water and is available round the clock

  18. Joint PET-MR respiratory motion models for clinical PET motion correction

    NASA Astrophysics Data System (ADS)

    Manber, Richard; Thielemans, Kris; Hutton, Brian F.; Wan, Simon; McClelland, Jamie; Barnes, Anna; Arridge, Simon; Ourselin, Sébastien; Atkinson, David

    2016-09-01

    Patient motion due to respiration can lead to artefacts and blurring in positron emission tomography (PET) images, in addition to quantification errors. The integration of PET with magnetic resonance (MR) imaging in PET-MR scanners provides complementary clinical information, and allows the use of high spatial resolution and high contrast MR images to monitor and correct motion-corrupted PET data. In this paper we build on previous work to form a methodology for respiratory motion correction of PET data, and show it can improve PET image quality whilst having minimal impact on clinical PET-MR protocols. We introduce a joint PET-MR motion model, using only 1 min per PET bed position of simultaneously acquired PET and MR data to provide a respiratory motion correspondence model that captures inter-cycle and intra-cycle breathing variations. In the model setup, 2D multi-slice MR provides the dynamic imaging component, and PET data, via low spatial resolution framing and principal component analysis, provides the model surrogate. We evaluate different motion models (1D and 2D linear, and 1D and 2D polynomial) by computing model-fit and model-prediction errors on dynamic MR images on a data set of 45 patients. Finally we apply the motion model methodology to 5 clinical PET-MR oncology patient datasets. Qualitative PET reconstruction improvements and artefact reduction are assessed with visual analysis, and quantitative improvements are calculated using standardised uptake value (SUVpeak and SUVmax) changes in avid lesions. We demonstrate the capability of a joint PET-MR motion model to predict respiratory motion by showing significantly improved image quality of PET data acquired before the motion model data. The method can be used to incorporate motion into the reconstruction of any length of PET acquisition, with only 1 min of extra scan time, and with no external hardware required.

  19. Positron Emission Tomography (PET)

    DOE R&D Accomplishments Database

    Welch, M. J.

    1990-01-01

    Positron emission tomography (PET) assesses biochemical processes in the living subject, producing images of function rather than form. Using PET, physicians are able to obtain not the anatomical information provided by other medical imaging techniques, but pictures of physiological activity. In metaphoric terms, traditional imaging methods supply a map of the body's roadways, its, anatomy; PET shows the traffic along those paths, its biochemistry. This document discusses the principles of PET, the radiopharmaceuticals in PET, PET research, clinical applications of PET, the cost of PET, training of individuals for PET, the role of the United States Department of Energy in PET, and the futures of PET.

  20. [Disposal of radioactive contaminated waste from Ga-68-PET - calculation of a clearance level for Ge-68].

    PubMed

    Solle, Alexander; Wanke, Carsten; Geworski, Lilli

    2017-03-01

    Ga-68-labeled radiotracers, particularly used for the detection of neuroendocrine tumors by means of Ga-68-DOTA-TATE or -DOTA-TOC or for the diagnosis of prostate cancer by means of Ga-68-labeled antigens (Ga 68-PSMA), become increasingly important. In addition to the high sensitivity and specificity of these radiopharmaceuticals, the short-lived radionuclide Ga-68 offers almost ideal nuclear characteristics for use in PET. Ga-68 is obtained from a germanium-gallium-generator system, so that the availability of Ga-68-labeled radiotracers is independent of an on-site-cyclotron regardless of the short half-life of Ga-68 of about 68minutes. Regarding the disposal of the radioactively contaminated waste from the preparation of the radiopharmaceutical, the eluted Ga-68 has to be considered to be additionally contaminated with its parent nuclide Ge-68. Due to this production-related impurity in combination with the short half-life of Ga-68, the radioactive waste has to be considered to be contaminated with Ge-68 and Ga-68 in radioactive equilibrium (hereafter referred to as Ge-68+). As there are no clearance levels for Ge-68+ given in the German Radiation Protection Ordinance, this work presents a method to calculate the missing value basing on a recommendation of the German Radiation Protection Commission in combination with simple geometric models of practical radiation protection. Regarding the relevant exposure scenarios, a limit value for the unrestricted clearance of Ge-68+ of 0.4 Bq/g was determined. Copyright © 2016. Published by Elsevier GmbH.

  1. The mechanical properties of brick containing recycled concrete aggregate and polyethylene terephthalate waste as sand replacement

    NASA Astrophysics Data System (ADS)

    Sheikh Khalid, Faisal; Bazilah Azmi, Nurul; Natasya Mazenan, Puteri; Shahidan, Shahiron; Ali, Noorwirdawati

    2018-03-01

    This research focuses on the performance of composite sand cement brick containing recycle concrete aggregate and waste polyethylene terephthalate. This study aims to determine the mechanical properties such as compressive strength and water absorption of composite brick containing recycled concrete aggregate (RCA) and polyethylene terephthalate (PET) waste. The bricks specimens were prepared by using 100% natural sand, they were then replaced by RCA at 25%, 50% and 75% with proportions of PET consists of 0.5%, 1.0% and 1.5% by weight of natural sand. Based on the results of compressive strength, only RCA 25% with 0.5% PET achieve lower strength than normal bricks while others showed a high strength. However, all design mix reaches strength more than 7N/mm2 as expected. Besides that, the most favorable mix design that achieves high compressive strength is 75% of RCA with 0.5% PET.

  2. Bottle milk feeding and its association with food group consumption, growth and socio-demographic characteristics in Chinese young children.

    PubMed

    Yeung, Suey; Chan, Ruth; Li, Liz; Leung, Shirley; Woo, Jean

    2017-07-01

    It is recommended that infants from the age of 12 months should be weaned from bottles. However, an overwhelming proportion of young children were still using bottle after the recommended age of bottle-weaning. This cross-sectional study examined the association between utensils for milk drinking and food group consumption, growth and socio-demographic characteristics among young children. Data from the Survey of Infant and Young Child Feeding in Hong Kong were analyzed for 649 children aged 18-48 months old. Dietary outcomes were obtained via 3-day dietary records, while utensils for milk drinking and socio-demographic characteristics were collected from a self-developed questionnaire. Length/height and weight of the children were measured by the nurses. Results showed that daily consumption of formula milk was significantly greater among bottle users or bottle plus cup users than non-bottle users (p < 0.05). Exclusive bottle users had significantly lower intakes of meat and meat alternatives than bottle plus cup users for the 18 to 24-month group (p = 0.001) and lower intakes of fruits than non-bottle users in the 48-month group (p = 0.015). BMI z-score was significantly higher for exclusive bottle users than non-bottle users, even after adjusting for socio-economic factors and child's age (p = 0.006). The results showed that the milk drinking utensil was associated with the amount of formula milk and food group consumption as well as BMI z-score. There is a need to actively discourage prolonged bottle use in order to help young children develop good dietary habits. © 2016 John Wiley & Sons Ltd. © 2016 John Wiley & Sons Ltd.

  3. 10 CFR 431.292 - Definitions concerning refrigerated bottled or canned beverage vending machines.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... beverage vending machines. 431.292 Section 431.292 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY... Vending Machines § 431.292 Definitions concerning refrigerated bottled or canned beverage vending machines. Basic model means, with respect to refrigerated bottled or canned beverage vending machines, all units...

  4. Indoor cultivation and cultural characteristics of Wolfiporia cocos sclerotia using mushroom culture bottles.

    PubMed

    Kubo, Toshiyuki; Terabayashi, Susumu; Takeda, Shuichi; Sasaki, Hiroshi; Aburada, Masaki; Miyamoto, Ken-ichi

    2006-06-01

    We newly developed an indoor cultivation technique for Wolfiporia cocos (Wolf) Ryvarden et Gilbertson (Syn. Poria cocos Wolf), not with soil, but using mushroom culture bottles with pine logs, and clarified some cultural characteristics of sclerotia in the laboratory. To determine the optimum conditions for sclerotia growth, the weight of sclerotia and concentration of CO2 in three different air filters; cloth, paper and urethane resin, and closed bottles were tested. When the cloth air filter was used, the growth rate was the fastest and the yield was maximal. These results suggested that the aeration was an important environmental factor for cultivation. To clarify the characteristics of culture in the cloth air filtered and closed bottles, the weight of sclerotia, the compositions of pine logs and the contents of pachymic acid and dehydropachymic acid were examined during 24 weeks. The growth of scleroia and the wood decaying efficiency in the cloth air filtered bottles were better than those in the closed bottles. Also, it was found that W. cocos was a brown rot fungus due to the alkaline solubility of pine logs in the wood decay process. In addition, the contents of pachymic acid and dehydropachymic acid and the TLC pattern between the cultivated and commercial sclerotia did not differ remarkably.

  5. Optical vault: a reconfigurable bottle beam based on conical refraction of light.

    PubMed

    Turpin, A; Shvedov, V; Hnatovsky, C; Loiko, Yu V; Mompart, J; Krolikowski, W

    2013-11-04

    We employ conical refraction of light in a biaxial crystal to create an optical bottle for photophoretic trapping and manipulation of particles in gaseous media. We show that by only varying the polarization state of the input light beam the optical bottle can be opened and closed in order to load and unload particles in a highly controllable manner.

  6. 21 CFR 189.301 - Tin-coated lead foil capsules for wine bottles.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 3 2012-04-01 2012-04-01 false Tin-coated lead foil capsules for wine bottles... Substances Prohibited From Indirect Addition to Human Food Through Food-Contact Surfaces § 189.301 Tin-coated lead foil capsules for wine bottles. (a) Tin-coated lead foil is composed of a lead foil coated on one...

  7. 21 CFR 189.301 - Tin-coated lead foil capsules for wine bottles.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Tin-coated lead foil capsules for wine bottles. 189... Substances Prohibited From Indirect Addition to Human Food Through Food-Contact Surfaces § 189.301 Tin-coated lead foil capsules for wine bottles. (a) Tin-coated lead foil is composed of a lead foil coated on one...

  8. 21 CFR 189.301 - Tin-coated lead foil capsules for wine bottles.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 3 2011-04-01 2011-04-01 false Tin-coated lead foil capsules for wine bottles... Substances Prohibited From Indirect Addition to Human Food Through Food-Contact Surfaces § 189.301 Tin-coated lead foil capsules for wine bottles. (a) Tin-coated lead foil is composed of a lead foil coated on one...

  9. 21 CFR 189.301 - Tin-coated lead foil capsules for wine bottles.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 3 2013-04-01 2013-04-01 false Tin-coated lead foil capsules for wine bottles... Substances Prohibited From Indirect Addition to Human Food Through Food-Contact Surfaces § 189.301 Tin-coated lead foil capsules for wine bottles. (a) Tin-coated lead foil is composed of a lead foil coated on one...

  10. Effect of Fungal Competition on Decay Rates in Bicultured Soil Bottle Assays

    Treesearch

    Grant T. Kirker; Amy Blodgett; Patricia K. Lebow; Carol A. Clausen

    2016-01-01

    For decades, wood scientists and preservative formulators have employed the monocultured soil bottle assay to test efficacy of wood treatment in the laboratory as a rapid predictor of field performance. This study examines the effects of bicultured soil bottle assays on the decay by common wood decay fungi. Mycelial interactions were noted in early stages of...

  11. Does bottle type and acid-washing influence trace element analyses by ICP-MS on water samples? A test covering 62 elements and four bottle types: high density polyethene (HDPE), polypropene (PP), fluorinated ethene propene copolymer (FEP) and perfluoroalkoxy polymer (PFA).

    PubMed

    Reimann, C; Siewers, U; Skarphagen, H; Banks, D

    1999-10-01

    Groundwater samples from 15 boreholes in crystalline bedrock aquifers in South Norway (Oslo area) have been collected in parallel in five different clear plastic bottle types (high density polyethene [HDPE], polypropene [PP, two manufacturers], fluorinated ethene propene copolymer [FEP] and perfluoroalkoxy polymer [PFA]. In the cases of polyethene and polypropene, parallel samples have been collected in factory-new (unwashed) bottles and acid-washed factory-new bottles. Samples have been analysed by ICP-MS techniques for a wide range of inorganic elements down to the ppt (ng/l) range. It was found that acid-washing of factory-new flasks had no clear systematic beneficial effect on analytical result. On the contrary, for the PP-bottles concentrations of Pb and Sn were clearly elevated in the acid-washed bottles. Likewise, for the vast majority of elements, bottle type was of no importance for analytical result. For six elements (Al, Cr, Hf, Hg, Pb and Sn) some systematic differences for one or more bottle types could be tentatively discerned, but in no case was the discrepancy of major cause for concern. The most pronounced effect was for Cr, with clearly elevated concentrations returned from the samples collected in HDPE bottles, regardless of acid-washing or not. For the above six elements, FEP or PFA bottles seemed to be marginally preferable to PP and HDPE. In general, cheap HDPE, factory new, unwashed flasks are suitable for sampling waters for ICP-MS ultra-trace analysis of the elements tested.

  12. An effective purification method using large bottles for human pancreatic islet isolation

    PubMed Central

    Shimoda, Masayuki; Itoh, Takeshi; Iwahashi, Shuichi; Takita, Morihito; Sugimoto, Koji; Kanak, Mazhar A.; Chujo, Daisuke; Naziruddin, Bashoo; Levy, Marlon F.; Grayburn, Paul A.; Matsumoto, Shinichi

    2012-01-01

    The purification process is one of the most difficult procedures in pancreatic islet isolation. It was demonstrated that the standard purification method using a COBE 2991 cell processor with Ficoll density gradient solution harmed islets mechanically by high shear force. We reported that purification using large bottles with a lower viscosity gradient solution could improve the efficacy of porcine islet purification. In this study, we examined whether the new bottle purification method could improve the purification of human islets. Nine human pancreata from brain-dead donors were used. After pancreas digestion, the digested tissue was divided into three groups. Each group was purified by continuous density gradient using ET-Kyoto and iodixanol gradient solution with either the standard COBE method (COBE group) or the top loading (top group) or bottom loading (bottom group) bottle purification methods. Islet yield, purity, recovery rate after purification, and in vitro and in vivo viability were compared. Islet yield per pancreas weight (IE/g) and the recovery rate in the top group were significantly higher than in the COBE and bottom groups. Furthermore, the average size of purified islets in the top group was significantly larger than in the COBE group, which indicated that the bottle method could reduce the shear force to the islets. In vivo viability was also significantly higher in the top group compared with the COBE group. In conclusion, the top-loading bottle method could improve the quality and quantity of human islets after purification. PMID:23221740

  13. Colorectal cancer staging: comparison of whole-body PET/CT and PET/MR.

    PubMed

    Catalano, Onofrio A; Coutinho, Artur M; Sahani, Dushyant V; Vangel, Mark G; Gee, Michael S; Hahn, Peter F; Witzel, Thomas; Soricelli, Andrea; Salvatore, Marco; Catana, Ciprian; Mahmood, Umar; Rosen, Bruce R; Gervais, Debra

    2017-04-01

    Correct staging is imperative for colorectal cancer (CRC) since it influences both prognosis and management. Several imaging methods are used for this purpose, with variable performance. Positron emission tomography-magnetic resonance (PET/MR) is an innovative imaging technique recently employed for clinical application. The present study was undertaken to compare the staging accuracy of whole-body positron emission tomography-computed tomography (PET/CT) with whole-body PET/MR in patients with both newly diagnosed and treated colorectal cancer. Twenty-six patients, who underwent same day whole-body (WB) PET/CT and WB-PET/MR, were evaluated. PET/CT and PET/MR studies were interpreted by consensus by a radiologist and a nuclear medicine physician. Correlations with prior imaging and follow-up studies were used as the reference standard. Correct staging was compared between methods using McNemar's Chi square test. The two methods were in agreement and correct for 18/26 (69%) patients, and in agreement and incorrect for one patient (3.8%). PET/MR and PET/CT stages for the remaining 7/26 patients (27%) were discordant, with PET/MR staging being correct in all seven cases. PET/MR significantly outperformed PET/CT overall for accurate staging (P = 0.02). PET/MR outperformed PET/CT in CRC staging. PET/MR might allow accurate local and distant staging of CRC patients during both at the time of diagnosis and during follow-up.

  14. Terminal acidic shock inhibits sour beer bottle conditioning by Saccharomyces cerevisiae.

    PubMed

    Rogers, Cody M; Veatch, Devon; Covey, Adam; Staton, Caleb; Bochman, Matthew L

    2016-08-01

    During beer fermentation, the brewer's yeast Saccharomyces cerevisiae experiences a variety of shifting growth conditions, culminating in a low-oxygen, low-nutrient, high-ethanol, acidic environment. In beers that are bottle conditioned (i.e., carbonated in the bottle by supplying yeast with a small amount of sugar to metabolize into CO2), the S. cerevisiae cells must overcome these stressors to perform the ultimate act in beer production. However, medium shock caused by any of these variables can slow, stall, or even kill the yeast, resulting in production delays and economic losses. Here, we describe a medium shock caused by high lactic acid levels in an American sour beer, which we refer to as "terminal acidic shock". Yeast exposed to this shock failed to bottle condition the beer, though they remained viable. The effects of low pH/high [lactic acid] conditions on the growth of six different brewing strains of S. cerevisiae were characterized, and we developed a method to adapt the yeast to growth in acidic beer, enabling proper bottle conditioning. Our findings will aid in the production of sour-style beers, a trending category in the American craft beer scene. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. Dose Optimization in TOF-PET/MR Compared to TOF-PET/CT

    PubMed Central

    Queiroz, Marcelo A.; Delso, Gaspar; Wollenweber, Scott; Deller, Timothy; Zeimpekis, Konstantinos; Huellner, Martin; de Galiza Barbosa, Felipe; von Schulthess, Gustav; Veit-Haibach, Patrick

    2015-01-01

    Purpose To evaluate the possible activity reduction in FDG-imaging in a Time-of-Flight (TOF) PET/MR, based on cross-evaluation of patient-based NECR (noise equivalent count rate) measurements in PET/CT, cross referencing with phantom-based NECR curves as well as initial evaluation of TOF-PET/MR with reduced activity. Materials and Methods A total of 75 consecutive patients were evaluated in this study. PET/CT imaging was performed on a PET/CT (time-of-flight (TOF) Discovery D 690 PET/CT). Initial PET/MR imaging was performed on a newly available simultaneous TOF-PET/MR (Signa PET/MR). An optimal NECR for diagnostic purposes was defined in clinical patients (NECRP) in PET/CT. Subsequent optimal activity concentration at the acquisition time ([A]0) and target NECR (NECRT) were obtained. These data were used to predict the theoretical FDG activity requirement of the new TOF-PET/MR system. Twenty-five initial patients were acquired with (retrospectively reconstructed) different imaging times equivalent for different activities on the simultaneous PET/MR for the evaluation of clinically realistic FDG-activities. Results The obtained values for NECRP, [A]0 and NECRT were 114.6 (± 14.2) kcps (Kilocounts per second), 4.0 (± 0.7) kBq/mL and 45 kcps, respectively. Evaluating the NECRT together with the phantom curve of the TOF-PET/MR device, the theoretical optimal activity concentration was found to be approximately 1.3 kBq/mL, which represents 35% of the activity concentration required by the TOF-PET/CT. Initial evaluation on patients in the simultaneous TOF-PET/MR shows clinically realistic activities of 1.8 kBq/mL, which represent 44% of the required activity. Conclusion The new TOF-PET/MR device requires significantly less activity to generate PET-images with good-to-excellent image quality, due to improvements in detector geometry and detector technologies. The theoretically achievable dose reduction accounts for up to 65% but cannot be fully translated into clinical

  16. What's Wrong with the Tap? Examining Perceptions of Tap Water and Bottled Water at Purdue University

    NASA Astrophysics Data System (ADS)

    Saylor, Amber; Prokopy, Linda Stalker; Amberg, Shannon

    2011-09-01

    The environmental impacts of bottled water prompted us to explore drinking water choices at Purdue University, located in West Lafayette, IN. A random sample of 2,045 Purdue University students, staff, and faculty was invited to participate in an online survey. The survey assessed current behaviors as well as perceived barriers and benefits to drinking tap water versus bottled water. 677 surveys were completed for a response rate of 33.1%. We then conducted qualitative interviews with a purposive sample of university undergraduates ( n = 21) to obtain contextual insights into the survey results and the beliefs of individuals with a variety of drinking water preferences. This study revealed that women drink disproportionately more bottled water then men while undergraduate students drink more than graduate students, staff and faculty. The study also uncovered a widespread belief that recycling eliminates the environmental impacts of bottled water. Important barriers to drinking tap water at Purdue include: perceived risks from tap water and the perceived safety of bottled water, preferring the taste of bottled water, and the convenience of drinking bottled water. The qualitative interviews revealed that drinking water choices can be influenced by several factors—especially whether individuals trust tap water to be clean—but involve varying levels of complexity. The implications of these results for social marketing strategies to promote tap water are discussed.

  17. What's wrong with the tap? Examining perceptions of tap water and bottled water at Purdue University.

    PubMed

    Saylor, Amber; Prokopy, Linda Stalker; Amberg, Shannon

    2011-09-01

    The environmental impacts of bottled water prompted us to explore drinking water choices at Purdue University, located in West Lafayette, IN. A random sample of 2,045 Purdue University students, staff, and faculty was invited to participate in an online survey. The survey assessed current behaviors as well as perceived barriers and benefits to drinking tap water versus bottled water. 677 surveys were completed for a response rate of 33.1%. We then conducted qualitative interviews with a purposive sample of university undergraduates (n = 21) to obtain contextual insights into the survey results and the beliefs of individuals with a variety of drinking water preferences. This study revealed that women drink disproportionately more bottled water then men while undergraduate students drink more than graduate students, staff and faculty. The study also uncovered a widespread belief that recycling eliminates the environmental impacts of bottled water. Important barriers to drinking tap water at Purdue include: perceived risks from tap water and the perceived safety of bottled water, preferring the taste of bottled water, and the convenience of drinking bottled water. The qualitative interviews revealed that drinking water choices can be influenced by several factors-especially whether individuals trust tap water to be clean-but involve varying levels of complexity. The implications of these results for social marketing strategies to promote tap water are discussed.

  18. A mass balance model to estimate the rate of composting, methane oxidation and anaerobic digestion in soil covers and shallow waste layers.

    PubMed

    Rafiee, Reza; Obersky, Lizanne; Xie, Sihuang; Clarke, William P

    2017-05-01

    Although CH 4 oxidation in landfill soil covers is widely studied, the extent of composting and CH 4 oxidation in underlying waste layers has been speculated but not measured. The objective of this study was to develop and validate a mass balance model to estimate the simultaneous rates of anaerobic digestion (r AD ), CH 4 oxidation (r OX ) and composting (r COM ) in environments where O 2 penetration is variable and zones of aerobic and anaerobic activity are intermingled. The modelled domain could include, as an example, a soil cover and the underlying shallow waste to a nominated depth. The proposed model was demonstrated on a blend of biogas from three separate known sources of gas representing the three reaction processes: (i) a bottle of laboratory grade 50:50% CH 4 :CO 2 gas representing anaerobic digestion biogas; (ii) an aerated 250mL bottle containing food waste that represented composting activity; and (iii) an aerated 250mL bottle containing non-degradable graphite granules inoculated with methanotrophs and incubated with CH 4 and O 2 to represent methanotrophic activity. CO 2 , CH 4 , O 2 and the stable isotope 13 C-CO 2 were chosen as the components for the mass balance model. The three reaction rates, r (=r AD , r OX , r COM ) were calculated as fitting parameters to the overdetermined set of 4mass balance equations with the net flux of these components from the bottles q (= [Formula: see text] , [Formula: see text] , [Formula: see text] and [Formula: see text] ) as inputs to the model. The coefficient of determination (r 2 ) for observed versus modelled values of r were 1.00, 0.97, 0.98 when the stoichiometry of each reaction was based on gas yields measured in the individual bottles and q was calculated by summing yields from the three bottles. r 2 deteriorated to 0.95, 0.96, 0.87 when using an average stoichiometry from 11 incubations of each of the composting and methane oxidation processes. The significant deterioration in the estimation of r

  19. 10 CFR 431.292 - Definitions concerning refrigerated bottled or canned beverage vending machines.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... cooled, and is not a combination vending machine. Class B means any refrigerated bottled or canned beverage vending machine not considered to be Class A, and is not a combination vending machine. Combination vending machine means a refrigerated bottled or canned beverage vending machine that also has non...

  20. Multi-Generational Drinking of Bottled Low Mineral Water Impairs Bone Quality in Female Rats

    PubMed Central

    Zeng, Hui; Wang, Lingqiao; Wang, Dahua; Luo, Jiaohua; Zhang, Liang; Huang, Yujing; Chen, Ji-an; Shu, Weiqun

    2015-01-01

    Background Because of reproductions and hormone changes, females are more sensitive to bone mineral loss during their lifetime. Bottled water has become more popular in recent years, and a large number of products are low mineral water. However, research on the effects of drinking bottled low mineral water on bone health is sparse. Objective To elucidate the skeletal effects of multi-generational bottled water drinking in female rats. Methods Rats continuously drank tap water (TW), bottled natural water (bNW), bottled mineralized water (bMW), or bottled purified water (bPW) for three generations. Results The maximum deflection, elastic deflection, and ultimate strain of the femoral diaphysis in the bNW, bMW, and bPW groups and the fracture strain in the bNW and bMW groups were significantly decreased. The tibiae calcium levels in both the bNW and bPW groups were significantly lower than that in the TW group. The tibiae and teeth magnesium levels in both the bNW and bPW groups were significantly lower than those in the TW group. The collagen turnover markers PICP (in both bNW and bPW groups) were significantly lower than that in the TW group. In all three low mineral water groups, the 1,25-dihydroxy-vitamin D levels were significantly lower than those in the TW group. Conclusion Long-term drinking of low mineral water may disturb bone metabolism and biochemical properties and therefore weaken biomechanical bone properties in females. Drinking tap water, which contains adequate minerals, was found to be better for bone health. To our knowledge, this is the first report on drinking bottled low mineral water and female bone quality on three generation model. PMID:25803851

  1. Simultaneous PET/MR imaging with a radio frequency-penetrable PET insert

    PubMed Central

    Grant, Alexander M.; Lee, Brian J.; Chang, Chen-Ming; Levin, Craig S.

    2017-01-01

    Purpose A brain sized radio-frequency (RF)-penetrable PET insert has been designed for simultaneous operation with MRI systems. This system takes advantage of electro-optical coupling and battery power to electrically float the PET insert relative to the MRI ground, permitting RF signals to be transmitted through small gaps between the modules that form the PET ring. This design facilitates the use of the built-in body coil for RF transmission, and thus could be inserted into any existing MR site wishing to achieve simultaneous PET/MR imaging. The PET detectors employ non-magnetic silicon photomultipliers in conjunction with a compressed sensing signal multiplexing scheme, and optical fibers to transmit analog PET detector signals out of the MRI room for decoding, processing, and image reconstruction. Methods The PET insert was first constructed and tested in a laboratory benchtop setting, where tomographic images of a custom resolution phantom were successfully acquired. The PET insert was then placed within a 3T body MRI system, and tomographic resolution/contrast phantom images were acquired both with only the B0 field present, and under continuous pulsing from different MR imaging sequences. Results The resulting PET images have comparable contrast-to-noise ratios (CNR) under all MR pulsing conditions: the maximum percent CNR relative difference for each rod type among all four PET images acquired in the MRI system has a mean of 14.0±7.7%. MR images were successfully acquired through the RF-penetrable PET shielding using only the built-in MR body coil, suggesting that simultaneous imaging is possible without significant mutual interference. Conclusions These results show promise for this technology as an alternative to costly integrated PET/MR scanners; a PET insert that is compatible with any existing clinical MRI system could greatly increase the availability, accessibility, and dissemination of PET/MR. PMID:28102949

  2. 21 CFR 165.110 - Bottled water.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... bottles or other containers with no added ingredients except that it may optionally contain safe and... Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to... availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register...

  3. 21 CFR 189.301 - Tin-coated lead foil capsules for wine bottles.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 3 2014-04-01 2014-04-01 false Tin-coated lead foil capsules for wine bottles... Addition to Human Food Through Food-Contact Surfaces § 189.301 Tin-coated lead foil capsules for wine bottles. (a) Tin-coated lead foil is composed of a lead foil coated on one or both sides with a thin layer...

  4. Cavity-enhanced optical bottle beam as a mechanical amplifier

    NASA Astrophysics Data System (ADS)

    Freegarde, Tim; Dholakia, Kishan

    2002-07-01

    We analyze the resonant cavity enhancement of a hollow ``optical bottle beam'' for the dipole-force trapping of dark-field-seeking species. We first improve upon the basic bottle beam by adding further Laguerre-Gaussian components to deepen the confining potential. Each of these components itself corresponds to a superposition of transverse cavity modes, which are then enhanced simultaneously in a confocal cavity to produce a deep optical trap needing only a modest incident power. The response of the trapping field to displacement of the cavity mirrors offers an unusual form of mechanical amplifier in which the Gouy phase shift produces an optical Vernier scale between the Laguerre-Gaussian beam components.

  5. PET/CT versus body coil PET/MRI: how low can you go?

    PubMed

    Appenzeller, P; Mader, C; Huellner, M W; Schmidt, D; Schmid, D; Boss, A; von Schulthess, G; Veit-Haibach, P

    2013-08-01

    The purpose of this study was to evaluate if positron emission tomography (PET)/magnetic resonance imaging (MRI) with just one gradient echo sequence using the body coil is diagnostically sufficient compared with a standard, low-dose non-contrast-enhanced PET/computed tomography (CT) concerning overall diagnostic accuracy, lesion detectability, size and conspicuity evaluation. Sixty-three patients (mean age 58 years, range 19-86 years; 23 women, 40 men) referred for either staging or restaging/follow-up of various malignant tumours (malignant melanoma, lung cancer, breast cancer, Hodgkin's lymphoma, non-Hodgkin's lymphoma, CUP, gynaecology tumours, pleural mesothelioma, oesophageal cancer, colorectal cancer, stomach cancer) were prospectively included. Imaging was conducted using a tri-modality PET/CT-MR set-up (full ring, time-of-flight Discovery PET/CT 690, 3 T Discovery MR 750, both GE Healthcare, Waukesha, WI). All patients were positioned on a dedicated PET/CT- and MR-compatible examination table, allowing for patient transport from the MR system to the PET/CT without patient movement. In accordance with RECIST 1.1 criteria, measurements of the maximum lesion diameters on CT and MR images were obtained. In lymph nodes, the short axis was measured. A four-point scale was used for assessment of lesion conspicuity: 1 (>25 % of lesion borders definable), 2 (25-50 %), 3 (50-75 %) and 4 (>75 %). For each lesion the corresponding anatomical structure was noted based on anatomical information of the spatially co-registered PET/CT and PET/MRI image sections. Additionally, lesions were divided into three categories: "tumour mass", "lymph nodes" and "lesions". Differences in overall lesion detectability and conspicuity in PET/CT and PET/MRI, as well as differences in detectability based on the localisation and lesion type, were analysed by Wilcoxon signed rank test. A total of 126 PET-positive lesions were evaluated. Overall, no statistically significant

  6. On the use of drift bottle and seabed drifter data in coastal management

    NASA Technical Reports Server (NTRS)

    Welch, C. S.; Norcross, J. J.

    1973-01-01

    The use of drift bottle and seabed drifter information for use in coastal management is discussed. The drift bottle/seabed drifter portion of VIMS project MACONS (Mid Atlantic Continental Shelf) is described as an example of how a comprehensive survey using drift bottles and seabed drifters provides data useful for coastal management. The data from MACONS are analyzed to answer specific questions of interest to several different coastal managers: a manager siting a deep oil port, one siting a sewage outfall, a manager responsible for setting up emergency beach protection procedures before an accident occurs, and a manager responsible for the environmental quality of a particular small section of coastline.

  7. The Dynamic Density Bottle: A Make-and-Take, Guided Inquiry Activity on Density

    ERIC Educational Resources Information Center

    Kuntzleman, Thomas S.

    2015-01-01

    An activity is described wherein students observe dynamic floating and sinking behavior of plastic pieces in various liquids. The liquids and solids are all contained within a plastic bottle; the entire assembly is called a "density bottle". After completing a series of experiments that guides students to think about the relative…

  8. Assessing bottled water nitrate concentrations to evaluate total drinking water nitrate exposure and risk of birth defects.

    PubMed

    Weyer, Peter J; Brender, Jean D; Romitti, Paul A; Kantamneni, Jiji R; Crawford, David; Sharkey, Joseph R; Shinde, Mayura; Horel, Scott A; Vuong, Ann M; Langlois, Peter H

    2014-12-01

    Previous epidemiologic studies of maternal exposure to drinking water nitrate did not account for bottled water consumption. The objective of this National Birth Defects Prevention Study (NBDPS) (USA) analysis was to assess the impact of bottled water use on the relation between maternal exposure to drinking water nitrate and selected birth defects in infants born during 1997-2005. Prenatal residences of 1,410 mothers reporting exclusive bottled water use were geocoded and mapped; 326 bottled water samples were collected and analyzed using Environmental Protection Agency Method 300.0. Median bottled water nitrate concentrations were assigned by community; mothers' overall intake of nitrate in mg/day from drinking water was calculated. Odds ratios for neural tube defects, limb deficiencies, oral cleft defects, and heart defects were estimated using mixed-effects models for logistic regression. Odds ratios (95% CIs) for the highest exposure group in offspring of mothers reporting exclusive use of bottled water were: neural tube defects [1.42 (0.51, 3.99)], limb deficiencies [1.86 (0.51, 6.80)], oral clefts [1.43 (0.61, 3.31)], and heart defects [2.13, (0.87, 5.17)]. Bottled water nitrate had no appreciable impact on risk for birth defects in the NBDPS.

  9. Effect of bottle height and aspiration rate on postocclusion surge in Infiniti and Millennium peristaltic phacoemulsification machines.

    PubMed

    Ward, Matthew S; Georgescu, Dan; Olson, Randall J

    2008-08-01

    To assess how flow and bottle height affect postocclusion surge in the Infiniti (Alcon, Inc.) and Millennium (Bausch & Lomb) peristaltic machines. John A. Moran Eye Center Clinical Laboratories, University of Utah, Salt Lake City, Utah. Postocclusion anterior chamber depth changes were measured in human eye-bank eyes using A-scan. Surge was simulated by clamping the aspiration tubing and releasing it at maximum vacuum. In both machines, surge was measured (1) with aspiration held constant at 12 mL/min and bottle heights at 60, 120, and 180 cm and (2) with bottle height held constant at 60 cm and aspiration rates at 12, 24, and 36 mL/min. Surge decreased approximately 40% with each 60 cm increase in bottle height in the Infiniti. It was constant at all bottle heights in the Millennium. At 12 and 24 mL/min aspiration rates, surge in the Millennium was less than half that in the Infiniti (P<.001). Postocclusion surge decreased linearly with increasing bottle height in the Infiniti system and was relatively constant with increasing bottle height in the Millennium system. The Millennium may offer a more stable phacoemulsification platform with respect to surge at a higher aspiration rate.

  10. Assessing bottled water nitrate concentrations to evaluate total drinking water nitrate exposure and risk of birth defects

    PubMed Central

    Weyer, Peter J.; Brender, Jean D.; Romitti, Paul A.; Kantamneni, Jiji R.; Crawford, David; Sharkey, Joseph R.; Shinde, Mayura; Horel, Scott A.; Vuong, Ann M.; Langlois, Peter H.

    2016-01-01

    Previous epidemiologic studies of maternal exposure to drinking water nitrate did not account for bottled water consumption. The objective of this National Birth Defects Prevention Study (NBDPS) (USA) analysis was to assess the impact of bottled water use on the relation between maternal exposure to drinking water nitrate and selected birth defects in infants born during 1997–2005. Prenatal residences of 1,410 mothers reporting exclusive bottled water use were geocoded and mapped; 326 bottled water samples were collected and analyzed using Environmental Protection Agency Method 300.0. Median bottled water nitrate concentrations were assigned by community; mothers’ overall intake of nitrate in mg/day from drinking water was calculated. Odds ratios for neural tube defects, limb deficiencies, oral cleft defects, and heart defects were estimated using mixed-effects models for logistic regression. Odds ratios (95% CIs) for the highest exposure group in offspring of mothers reporting exclusive use of bottled water were: neural tube defects [1.42 (0.51, 3.99)], limb deficiencies [1.86 (0.51, 6.80)], oral clefts [1.43 (0.61, 3.31)], and heart defects [2.13, (0.87, 5.17)]. Bottled water nitrate had no appreciable impact on risk for birth defects in the NBDPS. PMID:25473985

  11. 18F-FDG PET/MRI fusion in characterizing pancreatic tumors: comparison to PET/CT.

    PubMed

    Tatsumi, Mitsuaki; Isohashi, Kayako; Onishi, Hiromitsu; Hori, Masatoshi; Kim, Tonsok; Higuchi, Ichiro; Inoue, Atsuo; Shimosegawa, Eku; Takeda, Yutaka; Hatazawa, Jun

    2011-08-01

    To demonstrate that positron emission tomography (PET)/magnetic resonance imaging (MRI) fusion was feasible in characterizing pancreatic tumors (PTs), comparing MRI and computed tomography (CT) as mapping images for fusion with PET as well as fused PET/MRI and PET/CT. We retrospectively reviewed 47 sets of (18)F-fluorodeoxyglucose ((18)F -FDG) PET/CT and MRI examinations to evaluate suspected or known pancreatic cancer. To assess the ability of mapping images for fusion with PET, CT (of PET/CT), T1- and T2-weighted (w) MR images (all non-contrast) were graded regarding the visibility of PT (5-point confidence scale). Fused PET/CT, PET/T1-w or T2-w MR images of the upper abdomen were evaluated to determine whether mapping images provided additional diagnostic information to PET alone (3-point scale). The overall quality of PET/CT or PET/MRI sets in diagnosis was also assessed (3-point scale). These PET/MRI-related scores were compared to PET/CT-related scores and the accuracy in characterizing PTs was compared. Forty-three PTs were visualized on CT or MRI, including 30 with abnormal FDG uptake and 13 without. The confidence score for the visibility of PT was significantly higher on T1-w MRI than CT. The scores for additional diagnostic information to PET and overall quality of each image set in diagnosis were significantly higher on the PET/T1-w MRI set than the PET/CT set. The diagnostic accuracy was higher on PET/T1-w or PET/T2-w MRI (93.0 and 90.7%, respectively) than PET/CT (88.4%), but statistical significance was not obtained. PET/MRI fusion, especially PET with T1-w MRI, was demonstrated to be superior to PET/CT in characterizing PTs, offering better mapping and fusion image quality.

  12. Roof-harvested rainwater for potable purposes: application of solar disinfection (SODIS) and limitations.

    PubMed

    Amin, Muhammad Tahir; Han, Mooyoung

    2009-01-01

    Efficiency of solar disinfection (SODIS) was evaluated for the potability of rainwater in view of the increasing water and energy crises especially in developing countries. Rainwater samples were collected from an underground storage tank in 2 L polyethylene terephthalate (PET) bottles and SODIS efficiency was evaluated at different weather conditions. For optimizing SODIS, PET bottles with different backing surfaces to enhance the optical and thermal effects of SODIS were used and different physicochemical parameters were selected and evaluated along with microbial re-growth observations and calculating microbial decay constants. Total and fecal coliforms were used along with Escherichia Coli and Heterotrophic Plate Counts (HPC) as basic microbial and indicator organisms of water quality. For irradiance less than 600 W/m(2), reflective type PET bottles were best types while for radiations greater than 700 W/m(2), absorptive type PET bottles offered best solution due to the synergistic effects of both thermal and UV radiations. Microbial inactivation did not improve significantly by changing the initial pH and turbidity values but optimum SODIS efficiency is achieved for rainwater with acidic pH and low initial turbidity values by keeping air-spaced PET bottles in undisturbed conditions. Microbial re-growth occurred after one day only at higher turbidity values and with basic pH values. First-order reaction rate constant was in accordance with recent findings for TC but contradicted with previous researches for E. coli. No microbial parameter met drinking water guidelines even under strong experimental weather conditions rendering SODIS ineffective for complete disinfection and hence needed more exposure time or stronger sunlight radiations. With maximum possible storage of rainwater, however, and by using some means for accelerating SODIS process, rainwater can be disinfected and used for potable purposes.

  13. Light-induced changes in bottled white wine and underlying photochemical mechanisms.

    PubMed

    Grant-Preece, Paris; Barril, Celia; Schmidtke, Leigh M; Scollary, Geoffrey R; Clark, Andrew C

    2017-03-04

    Bottled white wine may be exposed to UV-visible light for considerable periods of time before it is consumed. Light exposure may induce an off-flavor known as "sunlight" flavor, bleach the color of the wine, and/or increase browning and deplete sulfur dioxide. The changes that occur in bottled white wine exposed to light depend on the wine composition, the irradiation conditions, and the light exposure time. The light-induced changes in the aroma, volatile composition, color, and concentrations of oxygen and sulfur dioxide in bottled white wine are reviewed. In addition, the photochemical reactions thought to have a role in these changes are described. These include the riboflavin-sensitized oxidation of methionine, resulting in the formation of methanethiol and dimethyl disulfide, and the photodegradation of iron(III) tartrate, which gives rise to glyoxylic acid, an aldehyde known to react with flavan-3-ols to form yellow xanthylium cation pigments.

  14. 10 CFR 431.294 - Uniform test method for the measurement of energy consumption of refrigerated bottled or canned...

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... consumption of refrigerated bottled or canned beverage vending machines. 431.294 Section 431.294 Energy... method for the measurement of energy consumption of refrigerated bottled or canned beverage vending... test procedure for energy consumption of refrigerated bottled or canned beverage vending machines shall...

  15. Joint Segmentation of Anatomical and Functional Images: Applications in Quantification of Lesions from PET, PET-CT, MRI-PET, and MRI-PET-CT Images

    PubMed Central

    Bagci, Ulas; Udupa, Jayaram K.; Mendhiratta, Neil; Foster, Brent; Xu, Ziyue; Yao, Jianhua; Chen, Xinjian; Mollura, Daniel J.

    2013-01-01

    We present a novel method for the joint segmentation of anatomical and functional images. Our proposed methodology unifies the domains of anatomical and functional images, represents them in a product lattice, and performs simultaneous delineation of regions based on random walk image segmentation. Furthermore, we also propose a simple yet effective object/background seed localization method to make the proposed segmentation process fully automatic. Our study uses PET, PET-CT, MRI-PET, and fused MRI-PET-CT scans (77 studies in all) from 56 patients who had various lesions in different body regions. We validated the effectiveness of the proposed method on different PET phantoms as well as on clinical images with respect to the ground truth segmentation provided by clinicians. Experimental results indicate that the presented method is superior to threshold and Bayesian methods commonly used in PET image segmentation, is more accurate and robust compared to the other PET-CT segmentation methods recently published in the literature, and also it is general in the sense of simultaneously segmenting multiple scans in real-time with high accuracy needed in routine clinical use. PMID:23837967

  16. Radiation damage and recovery properties of common plastics PEN (Polyethylene Naphthalate) and PET (Polyethylene Terephthalate) using a 137Cs gamma ray source up to 1.4 Mrad and 14 Mrad

    NASA Astrophysics Data System (ADS)

    Wetzel, J.; Tiras, E.; Bilki, B.; Onel, Y.; Winn, D.

    2016-08-01

    Polyethylene naphthalate (PEN) and polyethylene teraphthalate (PET) are cheap and common polyester plastics used throughout the world in the manufacturing of bottled drinks, containers for foodstuffs, and fibers used in clothing. These plastics are also known organic scintillators with very good scintillation properties. As particle physics experiments increase in energy and particle flux density, so does radiation exposure to detector materials. It is therefore important that scintillators be tested for radiation tolerance at these generally unheard of doses. We tested samples of PEN and PET using laser stimulated emission on separate tiles exposed to 1 Mrad and 10 Mrad gamma rays with a 137Cs source. PEN exposed to 1.4 Mrad and 14 Mrad emit 71.4% and 46.7% of the light of an undamaged tile, respectively, and maximally recover to 85.9% and 79.5% after 5 and 9 days, respectively. PET exposed to 1.4 Mrad and 14 Mrad emit 35.0% and 12.2% light, respectively, and maximally recover to 93.5% and 80.0% after 22 and 60 days, respectively.

  17. Effect of wine pH and bottle closure on tannins.

    PubMed

    McRae, Jacqui M; Kassara, Stella; Kennedy, James A; Waters, Elizabeth J; Smith, Paul A

    2013-11-27

    The impact of wine pH and closure type on color, tannin concentration, and composition was investigated. A single vintage of Cabernet Sauvignon wine was divided into three batches, the pH was adjusted to 3.2, 3.5 or 3.8, and the wines were bottled under screw caps with either SaranTin (ST) or Saranex (Sx) liners. After 24 months, the tannin concentration, tannin percent yield (relating to the proportion of acid-labile interflavan bonds), and the mean degree of polymerization (mDp) had decreased significantly, all of which can contribute to the softening of wine astringency with aging. The higher pH wines contained less percent (-)-epicatechin 3-O-gallate subunits, whereas the Sx pH 3.2 wines were significantly lower in percent yield and mDp than the other wines. Overall, the tannin structure and wine color of the lower pH wines (pH 3.2) bottled under Sx screw caps changed more rapidly with aging than those of the higher pH wines (pH 3.8) bottled under ST screw caps.

  18. Identification and quantification of the migration of chemicals from plastic baby bottles used as substitutes for polycarbonate.

    PubMed

    Simoneau, C; Van den Eede, L; Valzacchi, S

    2012-01-01

    The results of a study on the analytical identification and quantification of migration of chemicals from plastics baby bottles found in the European Union market made of materials that are now present as substitutes for polycarbonate (PC) are reported. A total of 449 baby bottles with a focus on first age or sets of bottles were purchased from 26 European Union countries, Canada, Switzerland and the USA. From this collection, which contained several duplicates, a total of 277 baby bottles were analysed. The materials included different types of plastic such as PC, polyamide (PA), polyethersulphone (PES), polypropylene (PP), but also silicone, and from the United States a co-polyester marketed under the trade name Tritan™. The bottles were subjected to the conventional migration test for hot fill conditions, i.e. 2 h at 70°C. The simulant used was that specified in European Union legislation (2007/19/EC) for milk, i.e. 50% ethanol. In a first phase 1, migration was conducted since the scope of this investigation was a screening rather than a true compliance testing check. Second and third migrations were performed on selected articles when migrated substances exceeded limits specified in the legislation. In order to verify some materials, a portion of the bottle was cut to run an FT-IR fingerprint to confirm the nature of the polymer. The migration solutions in general showed a low release of substances. Results showed that bottles made of PP and silicones showed a greater number of substances in the migration solutions and in greater quantity. Chemicals from PP included alkanes, which could be found in >65% of the bottles at levels up to 3500 µg kg⁻¹; and benzene derivatives in 17% of the baby bottles and found at levels up to 113 µg kg⁻¹. Some substances were found on a regular basis such as plasticisers, esters and antioxidants (e.g. tris(2,4-di-tert-butylphenyl)phosphate, known as Irgafos 168. Some substances found were not included in the

  19. Office-based intervention to reduce bottle use among toddlers: TARGet Kids! Pragmatic, randomized trial.

    PubMed

    Maguire, Jonathon L; Birken, Catherine S; Jacobson, Sheila; Peer, Michael; Taylor, Carolyn; Khambalia, Amina; Mekky, Magda; Thorpe, Kevin E; Parkin, Patricia

    2010-08-01

    The goal was to determine whether an office-based, educational intervention for parents of 9-month-old children could reduce bottle use and iron depletion at 2 years of age. Between January 2006 and 2007, 251 healthy, 9-month-old infants attending a routine health maintenance visit were assigned randomly to intervention or control groups. Parents in the intervention group were introduced to a 1-week protocol to wean their children from the bottle. Iron depletion (ferritin levels of <10 microg/L) and bottle use at 2 years were assessed. A total of 201 children were monitored to 2 years of age (follow-up rate: 81%). Rates of iron depletion (10 [10%] of 102 children vs 13 [13%] of 99 children; P = .42) and milk consumption of >16 oz (16 [16%] of 102 children vs 17 [17%] of 99 children; P = .7) were not significantly different between the 2 groups at 2 years of age. However, children in the intervention group started using a cup 3 months earlier (9 vs 12 months; P = .001), were weaned from the bottle 4 months earlier (12 vs 16 months; P = .004), and were more than one-half as likely to be using a bottle at 2 years of age (15 [15%] of 102 children vs 39 [40%] of 99 children; P = .0004). This simple intervention administered during a health maintenance visit did not result in a decrease in iron depletion at 2 years of age but did result in a 60% reduction in prolonged bottle use.

  20. The Egg in the Bottle Revisited: Air Pressure and Amontons' Law (Charles' Law).

    ERIC Educational Resources Information Center

    Adcock, Louis H.

    1998-01-01

    Presents instructions for putting a hard-boiled egg inside a bottle whose opening is slightly smaller than the egg's circumference, and for getting the egg out of the bottle. Also describes variations of the demonstration such as cooling the flask or using a banana. Cites incorrect and correct explanations of the demonstrated phenomenon. Contains…

  1. Bottle gourd genotypes vary in clomazone tolerance

    USDA-ARS?s Scientific Manuscript database

    A greenhouse trial was used to evaluate 159 accessions of bottle gourd (Lagenaria siceraria (Mol.) Standl.) obtained from the U.S. National Plant Germplasm for tolerance to clomazone herbicide. Most accessions tested were moderately or severely injured by clomazone at 3.0 mg/kg incorporated into gr...

  2. Photocatalytic Coats in Glass Drinking-Water Bottles

    NASA Technical Reports Server (NTRS)

    Andren, Anders W.; Armstrong, David E.; Anderson, Marc A.

    2005-01-01

    According to a proposal, the insides of glass bottles used to store drinking water would be coated with films consisting of or containing TiO2. In the presence of ultraviolet light, these films would help to remove bacteria, viruses, and trace organic contaminants from the water.

  3. Squeeze bottle apparatus with force multiplying pistons

    DOEpatents

    Moss, Owen R.; Gordon, Norman R.; DeFord, Henry S.; Eschbach, Eugene A.

    1994-01-01

    The present invention comprises a spray bottle in which the pressure resulting from the gripping force applied by the user is amplified and this increased pressure used in generating a spray such as an aerosol or fluid stream. In its preferred embodiment, the invention includes a high pressure chamber and a corresponding piston which is operative for driving fluid out of this chamber at high pressure through a spray nozzle and a low pressure chamber, and a corresponding piston which is acted upon by the hydraulic pressure within the bottle resulting from the gripping force. The low pressure chamber and piston are of larger size than the high pressure chamber and piston. The pistons are rigidly connected so that the force created by the pressure acting on the piston in the low pressure chamber is transmitted to the piston in the high pressure chamber where it is applied over a more limited area, thereby generating greater hydraulic pressure for use in forming the spray.

  4. Spray bottle apparatus with pressure multiplying pistons

    DOEpatents

    Moss, Owen R.; Gordon, Norman R.; DeFord, Henry S.

    1990-01-01

    The present invention comprises a spray bottle in which the pressure resulting from the gripping force applied by the user is amplified and this increased pressure used in generating a spray such as an aerosol or fluid stream. In its preferred embodiment, the invention includes a high pressure chamber and a corresponding piston which is operative for driving fluid out of this chamber at high pressure through a spray nozzle and a low pressure chamber and a corresponding piston which is acted upon the hydraulic pressure within the bottle resulting from the gripping force. The low pressure chamber and piston are of larger size than the high pressure chamber and piston. The pistons are rigidly connected so that the force created by the pressure acting on the piston in the low pressure chamber is transmitted to the piston in the high pressure chamber where it is applied over a more limited area thereby generating greater hydraulic pressure for use in forming the spray.

  5. Spray bottle apparatus with force multiply pistons

    DOEpatents

    Eschbach, Eugene A.

    1992-01-01

    The present invention comprises a spray bottle in which the pressure resulting from the gripping force applied by the user is amplified and this increased pressure used in generating a spray such as an aerosol or fluid stream. In its preferred embodiment, the invention includes a high pressure chamber and a corresponding piston which is operative for driving fluid out of this chamber at high pressure through a spray nozzle and a low pressure chamber and corresponding piston which is acted upon by the hydraulic pressure within the bottle resulting from the gripping force. The low pressure chamber and piston are of larger size than the high pressure chamber and piston. The pistons are rigidly connected so that the force created by the pressure acting on the piston in the low pressure chamber is transmitted to the piston in the high pressure chamber where it is applied over a more limited area thereby generating greater hydraulic pressure for use in forming the spray.

  6. Bottled beverages and typhoid fever: the Mexican epidemic of 1972-73.

    PubMed Central

    Gonzalez-Cortes, A; Gangarosa, E J; Parrilla, C; Martin, W T; Espinosa-Ayala, A M; Ruiz, L; Bessudo, D; Hernandez-Arreortua, H

    1982-01-01

    A chloramphenicol resistant strain of S. typhi which caused a very large epidemic of typhoid fever in Mexico in 1972-73 survived in opened bottles of one carbonated drink with a pH of 4.6 for two weeks and in another such drink with a pH of 5.1 for six months. Bottled beverages are potential sources of large outbreaks of enteric disease, and deserve the same type of standards sand monitoring as comparable fluids such as milk. PMID:7091481

  7. Synthetic Precipitation Leaching Procedure (SPLP) leachate chemistry data for solid mine-waste composite samples from southwestern New Mexico, and Leadville, Colorado

    USGS Publications Warehouse

    Hageman, Philip L.; Briggs, Paul H.; Desborough, George A.; Lamothe, Paul J.; Theodorakos, Peter M.

    2000-01-01

    This report details chemistry data derived from leaching of mine-waste composite samples using a modification of E.P.A. Method 1312, Synthetic Precipitation Leaching Procedure (SPLP). In 1998, members of the U.S. Geological Survey Mine Waste Characterization Project collected four mine-waste composite samples from mining districts in southwestern New Mexico (CAR and PET) and near Leadville, Colorado (TUC and MII). Resulting leachate pH values for the four composites ranged from 5.45 to 8.84 and ranked in the following order: CAR < TUC < MII < PET. Specific conductivity values ranged from 85 uS/cm to 847 uS/cm in the following order: PET < MII < CAR < TUC. Geochemical data generated from this investigation reveal that leachate from the CAR composite contains the highest concentrations of Pb, Zn, Ni, Mn, Cu, Cd, and Al

  8. Microbiological Investigations of ReNu Plastic Bottles and the 2004 to 2006 ReNu With MoistureLoc-Related Worldwide Fusarium Keratitis Event.

    PubMed

    Bullock, John D; Warwar, Ronald E; Elder, B Laurel; Khamis, Harry J

    2016-05-01

    The purposes of this study were to determine whether the contact lens solution RevitaLens Ocutec (containing the antimicrobial agents alexidine and polyquaternium-1) would inhibit Fusarium organisms when heated in ReNu plastic bottles; whether alexidine would inhibit Fusarium organisms when heated in non-ReNu plastic bottles; and whether an alexidine-neutralizing compound leaches from heated ReNu bottles. RevitaLens and an alexidine solution (0.00045%), previously stored in ReNu bottles at room temperature (RT) and 56°C, were incubated with 7 different Fusarium organisms. The alexidine solution was similarly stored in seven non-ReNu plastic bottles and incubated with these same organisms. To determine if an alexidine-neutralizing compound might be leaching from heated ReNu bottles, phosphate-buffered saline (PBS) was incubated at RT and 56°C in ReNu bottles, combined with alexidine, and then tested for anti-Fusarium capability. After being heated in ReNu bottles, RevitaLens retained its anti-Fusarium capability, whereas the alexidine solution did not. The alexidine solution heated in seven non-ReNu plastic bottles retained its anti-Fusarium capability. The alexidine solution retained its anti-Fusarium capability when incubated with a PBS solution that had been heated in ReNu bottles, indicating, microbiologically, that an alexidine-neutralizing compound did not leach from the heated ReNu bottle. Alexidine uniquely fails to inhibit Fusarium organisms when heated in a plastic ReNu bottle, but not in seven other plastic bottles, whereas the anti-Fusarium capability of RevitaLens (containing the antimicrobial agents alexidine and polyquaternium-1) is unaffected by heating in a ReNu bottle. There does not seem to be an alexidine-neutralizing compound leaching from heated ReNu bottles. An interaction between alexidine and its heated ReNu bottle may have been a critical factor in the worldwide ReNu with MoistureLoc-related Fusarium keratitis event of 2004 to 2006.

  9. Pet-Related Infections.

    PubMed

    Day, Michael J

    2016-11-15

    Physicians and veterinarians have many opportunities to partner in promoting the well-being of people and their pets, especially by addressing zoonotic diseases that may be transmitted between a pet and a human family member. Common cutaneous pet-acquired zoonoses are dermatophytosis (ringworm) and sarcoptic mange (scabies), which are both readily treated. Toxoplasmosis can be acquired from exposure to cat feces, but appropriate hygienic measures can minimize the risk to pregnant women. Persons who work with animals are at increased risk of acquiring bartonellosis (e.g., cat-scratch disease); control of cat fleas is essential to minimize the risk of these infections. People and their pets share a range of tick-borne diseases, and exposure risk can be minimized with use of tick repellent, prompt tick removal, and appropriate tick control measures for pets. Pets such as reptiles, amphibians, and backyard poultry pose a risk of transmitting Salmonella species and are becoming more popular. Personal hygiene after interacting with these pets is crucial to prevent Salmonella infections. Leptospirosis is more often acquired from wildlife than infected dogs, but at-risk dogs can be protected with vaccination. The clinical history in the primary care office should routinely include questions about pets and occupational or other exposure to pet animals. Control and prevention of zoonoses are best achieved by enhancing communication between physicians and veterinarians to ensure patients know the risks of and how to prevent zoonoses in themselves, their pets, and other people.

  10. Generation of acoustic self-bending and bottle beams by phase engineering

    NASA Astrophysics Data System (ADS)

    Zhang, Peng; Li, Tongcang; Zhu, Jie; Zhu, Xuefeng; Yang, Sui; Wang, Yuan; Yin, Xiaobo; Zhang, Xiang

    2014-07-01

    Directing acoustic waves along curved paths is critical for applications such as ultrasound imaging, surgery and acoustic cloaking. Metamaterials can direct waves by spatially varying the material properties through which the wave propagates. However, this approach is not always feasible, particularly for acoustic applications. Here we demonstrate the generation of acoustic bottle beams in homogeneous space without using metamaterials. Instead, the sound energy flows through a three-dimensional curved shell in air leaving a close-to-zero pressure region in the middle, exhibiting the capability of circumventing obstacles. By designing the initial phase, we develop a general recipe for creating self-bending wave packets, which can set acoustic beams propagating along arbitrary prescribed convex trajectories. The measured acoustic pulling force experienced by a rigid ball placed inside such a beam confirms the pressure field of the bottle. The demonstrated acoustic bottle and self-bending beams have potential applications in medical ultrasound imaging, therapeutic ultrasound, as well as acoustic levitations and isolations.

  11. J-PET: A New Technology for the Whole-body PET Imaging

    NASA Astrophysics Data System (ADS)

    Niedźwiecki, S.; Białas, P.; Curceanu, C.; Czerwiński, E.; Dulski, K.; Gajos, A.; Głowacz, B.; Gorgol, M.; Hiesmayr, B. C.; Jasińska, B.; Kapłon, Ł.; Kisielewska-Kamińska, D.; Korcyl, G.; Kowalski, P.; Kozik, T.; Krawczyk, N.; Krzemień, W.; Kubicz, E.; Mohammed, M.; Pawlik-Niedźwiecka, M.; Pałka, M.; Raczyński, L.; Rudy, Z.; Sharma, N. G.; Sharma, S.; Shopa, R. Y.; Silarski, M.; Skurzok, M.; Wieczorek, A.; Wiślicki, W.; Zgardzińska, B.; Zieliński, M.; Moskal, P.

    The Jagiellonian Positron Emission Tomograph (J-PET) is the first PET built from plastic scintillators. J-PET prototype consists of 192 detection modules arranged axially in three layers forming a cylindrical diagnostic chamber with the inner diameter of 85 cm and the axial field-of-view of 50 cm. An axial arrangement of long strips of plastic scintillators, their small light attenuation, superior timing properties, and relative ease of the increase of the axial field-of-view opens promising perspectives for the cost effective construction of the whole-body PET scanner, as well as construction of MR and CT compatible PET inserts. Present status of the development of the J-PET tomograph will be presented and discussed.

  12. 27 CFR 27.204 - Distinctive liquor bottles.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2014-04-01 2014-04-01 false Distinctive liquor bottles. 27.204 Section 27.204 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY ALCOHOL IMPORTATION OF DISTILLED SPIRITS, WINES, AND BEER Requirements for Liquor...

  13. 27 CFR 27.204 - Distinctive liquor bottles.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2013-04-01 2013-04-01 false Distinctive liquor bottles. 27.204 Section 27.204 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY ALCOHOL IMPORTATION OF DISTILLED SPIRITS, WINES, AND BEER Requirements for Liquor...

  14. Comparison of 18F-FDG PET/CT and PET/MRI in patients with multiple myeloma

    PubMed Central

    Sachpekidis, Christos; Hillengass, Jens; Goldschmidt, Hartmut; Mosebach, Jennifer; Pan, Leyun; Schlemmer, Heinz-Peter; Haberkorn, Uwe; Dimitrakopoulou-Strauss, Antonia

    2015-01-01

    PET/MRI represents a promising hybrid imaging modality with several potential clinical applications. Although PET/MRI seems highly attractive in the diagnostic approach of multiple myeloma (MM), its role has not yet been evaluated. The aims of this prospective study are to evaluate the feasibility of 18F-FDG PET/MRI in detection of MM lesions, and to investigate the reproducibility of bone marrow lesions detection and quantitative data of 18F-FDG uptake between the functional (PET) component of PET/CT and PET/MRI in MM patients. The study includes 30 MM patients. All patients initially underwent 18F-FDG PET/CT (60 min p.i.), followed by PET/MRI (120 min p.i.). PET/CT and PET/MRI data were assessed and compared based on qualitative (lesion detection) and quantitative (SUV) evaluation. The hybrid PET/MRI system provided good image quality in all cases without artefacts. PET/MRI identified 65 of the 69 lesions, which were detectable with PET/CT (94.2%). Quantitative PET evaluations showed the following mean values in MM lesions: SUVaverage=5.5 and SUVmax=7.9 for PET/CT; SUVaverage=3.9 and SUVmax=5.8 for PET/MRI. Both SUVaverage and SUVmax were significantly higher on PET/CT than on PET/MRI. Spearman correlation analysis demonstrated a strong correlation between both lesional SUVaverage (r=0.744) and lesional SUVmax (r=0.855) values derived from PET/CT and PET/MRI. Regarding detection of myeloma skeletal lesions, PET/MRI exhibited equivalent performance to PET/CT. In terms of tracer uptake quantitation, a significant correlation between the two techniques was demonstrated, despite the statistically significant differences in lesional SUVs between PET/CT and PET/MRI. PMID:26550538

  15. Metamorphosis in the Porosity of Recycled Concretes Through the Use of a Recycled Polyethylene Terephthalate (PET) Additive. Correlations between the Porous Network and Concrete Properties

    PubMed Central

    Mendivil-Escalante, José Miguel; Gómez-Soberón, José Manuel; Almaral-Sánchez, Jorge Luis; Cabrera-Covarrubias, Francisca Guadalupe

    2017-01-01

    In the field of construction, sustainable building materials are currently undergoing a process of technological development. This study aims to contribute to understanding the behavior of the fundamental properties of concretes prepared with recycled coarse aggregates that incorporate a polyethylene terephthalate (PET)-based additive in their matrix (produced by synthesis and glycolysis of recycled PET bottles) in an attempt to reduce their high porosity. Techniques to measure the gas adsorption, water porosity, Fourier transform infrared spectroscopy (FTIR) and X-ray diffraction (XRD) were used to evaluate the effect of the additive on the physical, mechanical and microstructural properties of these concretes. Porosity reductions of up to 30.60% are achieved with the addition of 1%, 3%, 4%, 5%, 7% and 9% of the additive, defining a new state in the behavioral model of the additive (the overdosage point) in the concrete matrix; in addition, the porous network of these concretes and their correlation with other physical and mechanical properties are also explained. PMID:28772540

  16. Metamorphosis in the Porosity of Recycled Concretes Through the Use of a Recycled Polyethylene Terephthalate (PET) Additive. Correlations between the Porous Network and Concrete Properties.

    PubMed

    Mendivil-Escalante, José Miguel; Gómez-Soberón, José Manuel; Almaral-Sánchez, Jorge Luis; Cabrera-Covarrubias, Francisca Guadalupe

    2017-02-14

    In the field of construction, sustainable building materials are currently undergoing a process of technological development. This study aims to contribute to understanding the behavior of the fundamental properties of concretes prepared with recycled coarse aggregates that incorporate a polyethylene terephthalate (PET)-based additive in their matrix (produced by synthesis and glycolysis of recycled PET bottles) in an attempt to reduce their high porosity. Techniques to measure the gas adsorption, water porosity, Fourier transform infrared spectroscopy (FTIR) and X-ray diffraction (XRD) were used to evaluate the effect of the additive on the physical, mechanical and microstructural properties of these concretes. Porosity reductions of up to 30.60% are achieved with the addition of 1%, 3%, 4%, 5%, 7% and 9% of the additive, defining a new state in the behavioral model of the additive (the overdosage point) in the concrete matrix; in addition, the porous network of these concretes and their correlation with other physical and mechanical properties are also explained.

  17. Effects of Water Bottle Materials and Filtration on Bisphenol A Content in Laboratory Animal Drinking Water.

    PubMed

    Honeycutt, Jennifer A; Nguyen, Jenny Q T; Kentner, Amanda C; Brenhouse, Heather C

    2017-05-01

    Bisphenol A (BPA) is widely used in the polycarbonate plastics and epoxy resins that are found in laboratory animal husbandry materials including cages and water bottles. Concerns about BPA exposure in humans has led to investigations that suggest physiologic health risks including disruptions to the endocrine system and CNS. However, the extent of exposure of laboratory animals to BPA in drinking water is unclear. In the first study, we compared the amount of BPA contamination in water stored in plastic bottles used in research settings with that in glass bottles. The amount of BPA that leached into water was measured across several time points ranging from 24 to 96 h by using a BPA ELISA assay. The results showed that considerable amounts of BPA (approximately 0.15 μg/L) leached from polycarbonate bottles within the first 24 h of storage. In the second study, BPA levels were measured directly from water taken from filtered compared with unfiltered taps. We observed significantly higher BPA levels in water from unfiltered taps (approximately 0.40 μg/L) compared with taps with filtration systems (approximately 0.04 μg/L). Taken together, our findings indicate that the use of different types of water bottles and water sources, combined with the use of different laboratory products (food, caging systems) between laboratories, likely contribute to decreased rigor and reproducibility in research. We suggest that researchers consider reporting the types of water bottles used and that animal care facilities educate staff regarding the importance of flushing nonfiltered water taps when filling animal water bottles.

  18. Effects of Water Bottle Materials and Filtration on Bisphenol A Content in Laboratory Animal Drinking Water

    PubMed Central

    Honeycutt, Jennifer A; Nguyen, Jenny Q T; Kentner, Amanda C; Brenhouse, Heather C

    2017-01-01

    Bisphenol A (BPA) is widely used in the polycarbonate plastics and epoxy resins that are found in laboratory animal husbandry materials including cages and water bottles. Concerns about BPA exposure in humans has led to investigations that suggest physiologic health risks including disruptions to the endocrine system and CNS. However, the extent of exposure of laboratory animals to BPA in drinking water is unclear. In the first study, we compared the amount of BPA contamination in water stored in plastic bottles used in research settings with that in glass bottles. The amount of BPA that leached into water was measured across several time points ranging from 24 to 96 h by using a BPA ELISA assay. The results showed that considerable amounts of BPA (approximately 0.15 μg/L) leached from polycarbonate bottles within the first 24 h of storage. In the second study, BPA levels were measured directly from water taken from filtered compared with unfiltered taps. We observed significantly higher BPA levels in water from unfiltered taps (approximately 0.40 μg/L) compared with taps with filtration systems (approximately 0.04 μg/L). Taken together, our findings indicate that the use of different types of water bottles and water sources, combined with the use of different laboratory products (food, caging systems) between laboratories, likely contribute to decreased rigor and reproducibility in research. We suggest that researchers consider reporting the types of water bottles used and that animal care facilities educate staff regarding the importance of flushing nonfiltered water taps when filling animal water bottles. PMID:28535862

  19. The health-related microbiological quality of bottled drinking water sold in Dar es Salaam, Tanzania.

    PubMed

    Kassenga, Gabriel R

    2007-03-01

    The consumption of bottled and plastic-bagged drinking water in Tanzania has increased largely because of the deteriorating quality of tap water. It is uncertain whether these water products are safe for drinking. In this study, the microbiological quality of bottled and plastic-bagged drinking water sold in Dar es Salaam, Tanzania, was investigated. One hundred and thirty samples representing 13 brands of bottled water collected from shops, supermarkets and street vendors were analysed for total coliform and faecal coliform organisms as well as heterotrophic bacteria. These were compared with 61 samples of tap water. Heterotrophic bacteria were detected in 92% of the bottled water samples analysed. Total and faecal coliform bacteria were present in 4.6% and 3.6%, respectively, of samples analysed with a tendency for higher contamination rates in plastic-bagged drinking water. Microbiological quality of tap water was found to be worse compared with bottled water, with 49.2% and 26.2% of sampling points showing the presence of total coliform and faecal coliform organisms, respectively. The results suggest caution and vigilance to avert outbreaks of waterborne diseases from these types of drinking water.

  20. Reproducibility of 18F-FDG PET uptake measurements in head and neck squamous cell carcinoma on both PET/CT and PET/MR

    PubMed Central

    Fischer, B M; Aznar, M C; Hansen, A E; Vogelius, I R; Löfgren, J; Andersen, F L; Loft, A; Kjaer, A; Højgaard, L; Specht, L

    2015-01-01

    Objective: To investigate reproducibility of fluorine-18 fludeoxyglucose (18F-FDG) uptake on 18F-FDG positron emission tomography (PET)/CT and 18F-FDG PET/MR scans in patients with head and neck squamous cell carcinoma (HNSCC). Methods: 30 patients with HNSCC were included in this prospective study. The patients were scanned twice before radiotherapy treatment with both PET/CT and PET/MR. Patients were scanned on the same scanners, 3 days apart and according to the same protocol. Metabolic tumour activity was measured by the maximum and peak standardized uptake value (SUVmax and SUVpeak, respectively), and total lesion glycolysis from the metabolic tumour volume defined from ≥50% SUVmax. Bland–Altman analysis with limits of agreement, coefficient of variation (CV) from the two modalities were performed in order to test the reproducibility. Furthermore, CVs from SUVmax and SUVpeak were compared. The area under the curve from cumulative SUV–volume histograms were measured and tested for reproducibility of the distribution of 18F-FDG uptake. Results: 24 patients had two pre-treatment PET/CT scans and 21 patients had two pre-treatment PET/MR scans available for further analyses. Mean difference for SUVmax, peak and mean was approximately 4% for PET/CT and 3% for PET/MR, with 95% limits of agreement less than ±20%. CV was small (5–7%) for both modalities. There was no significant difference in CVs between PET/CT and PET/MR (p = 0.31). SUVmax was not more reproducible than SUVpeak (p = 0.09). Conclusion: 18F-FDG uptake in PET/CT and PET/MR is highly reproducible and we found no difference in reproducibility between PET/CT and PET/MR. Advances in knowledge: This is the first report to test reproducibility of PET/CT and PET/MR. PMID:25634069

  1. Feasibility of FDG-PET in myocarditis: Comparison to CMR using integrated PET/MRI.

    PubMed

    Nensa, Felix; Kloth, Julia; Tezgah, Ercan; Poeppel, Thorsten D; Heusch, Philipp; Goebel, Juliane; Nassenstein, Kai; Schlosser, Thomas

    2018-06-01

    Besides cardiac sarcoidosis, FDG-PET is rarely used in the diagnosis of myocardial inflammation, while cardiac MRI (CMR) is the actual imaging reference for the workup of myocarditis. Using integrated PET/MRI in patients with suspected myocarditis, we prospectively compared FDG-PET to CMR and the feasibility of integrated FDG-PET/MRI in myocarditis. A total of 65 consecutive patients with suspected myocarditis were prospectively assessed using integrated cardiac FDG-PET/MRI. Studies comprised T2-weighted imaging, late gadolinium enhancement (LGE), and simultaneous PET acquisition. Physiological glucose uptake in the myocardium was suppressed using dietary preparation. FDG-PET/MRI was successful in 55 of 65 enrolled patients: two patients were excluded due to claustrophobia and eight patients due to failed inhibition of myocardial glucose uptake. Compared with CMR (LGE and/or T2), sensitivity and specificity of PET was 74% and 97%. Overall spatial agreement between PET and CMR was κ = 0.73. Spatial agreement between PET and T2 (κ = 0.75) was higher than agreement between PET and LGE (κ = 0.64) as well as between LGE and T2 (κ = 0.56). In patients with suspected myocarditis, FDG-PET is in good agreement with CMR findings.

  2. [Development of a screening scale for children at risk of baby bottle tooth decay].

    PubMed

    Khadra-Eid, J; Baudet, D; Fourny, M; Sellier, E; Brun, C; François, P

    2012-03-01

    Baby bottle tooth decay is a severe form of early childhood caries. This study aims to elaborate a screening tool for at risk children in order to facilitate primary prevention. A case-control study was conducted among children suffering from baby bottle tooth decay and children with no dental caries. Cases were children aged 5 years or less at diagnosis who experienced at least four caries with one or more affecting maxillary incisors. Controls were children matched for age and sex. Parents were interviewed by phone about their child's exposure to potential risk factors. We included 88 children suffering from baby bottle tooth decay and 88 children with no dental caries. In multivariate analysis, low social class (OR 6.39 [95% CI, 1.45-28.11]), prolonged bottle feeding or bedtime feeding (OR 153.2 [95% CI, 11.77-1994.96]), and snacking (OR 5.94 [95% CI, 1.35-26.2]) were significantly associated with baby bottle tooth decay. Regular dental visits were a significant protecting factor (OR 0.13 [95% CI, 0.02-0.77]). A score was developed using these significant risk factors and tested on the survey population. The mean score was 13/20 for cases and 4/20 for controls. These results are in accordance with the literature, except for brushing teeth, which was not significantly associated with baby bottle tooth decay in our study. A screening scale with a score of 20 points was proposed. Future validation is required. Pediatricians and general practitioners should encourage parents to change their habits. Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  3. Potential useful products from solid wastes.

    PubMed

    Golueke, C G; Diaz, L F

    1991-10-01

    Wastes have been aptly defined as "items, i.e. resources, that have been discarded because their possessors no longer have an apparent use for them". Accordingly, "wastes" have a significance only in relation to the items and those who have discarded them. The discarded items now are resources awaiting reclamation. Reclamation usually involves either salvage or conversion--or in modern terminology, "reuse" or "recycling". Reclamation for reuse consists in refurbishing or other upgrading without significantly altering original form and composition. Examples of wastes amenable to reuse are containers (bottles, etc.), cartons and repairable tires. With "recycling" (i.e. conservation), the discarded items are processed such that they become raw material, i.e. resources in the manufacture of "new" products. The variety of processes is wide, ranging from simply physical (grinding) through thermal (melting, gasification, combustion), to biological (composting, biogasification, hydrolysis, microbial protein production). In the paper, reuse and recycling (conversion) are evaluated in terms of advantages and disadvantages (limitations) and their respective technologies are described and discussed in detail.

  4. 27 CFR 27.204 - Distinctive liquor bottles.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2011-04-01 2011-04-01 false Distinctive liquor bottles. 27.204 Section 27.204 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU..., to Customs officials at each affected port of entry where the merchandise is examined. (Sec. 201, Pub...

  5. 27 CFR 27.204 - Distinctive liquor bottles.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2012-04-01 2012-04-01 false Distinctive liquor bottles. 27.204 Section 27.204 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU..., to Customs officials at each affected port of entry where the merchandise is examined. (Sec. 201, Pub...

  6. 27 CFR 26.314 - Distinctive liquor bottles.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2014-04-01 2014-04-01 false Distinctive liquor bottles. 26.314 Section 26.314 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY ALCOHOL LIQUORS AND ARTICLES FROM PUERTO RICO AND THE VIRGIN ISLANDS Requirements...

  7. ChIA-PET2: a versatile and flexible pipeline for ChIA-PET data analysis

    PubMed Central

    Li, Guipeng; Chen, Yang; Snyder, Michael P.; Zhang, Michael Q.

    2017-01-01

    ChIA-PET2 is a versatile and flexible pipeline for analyzing different types of ChIA-PET data from raw sequencing reads to chromatin loops. ChIA-PET2 integrates all steps required for ChIA-PET data analysis, including linker trimming, read alignment, duplicate removal, peak calling and chromatin loop calling. It supports different kinds of ChIA-PET data generated from different ChIA-PET protocols and also provides quality controls for different steps of ChIA-PET analysis. In addition, ChIA-PET2 can use phased genotype data to call allele-specific chromatin interactions. We applied ChIA-PET2 to different ChIA-PET datasets, demonstrating its significantly improved performance as well as its ability to easily process ChIA-PET raw data. ChIA-PET2 is available at https://github.com/GuipengLi/ChIA-PET2. PMID:27625391

  8. Quality control of bottled and vended water in California: A review and comparison to tap water

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Darby, J.L.; Allen, L.

    1994-04-01

    Current regulations and compliance for quality control of bottled and vended water in California are compared with that of the tap water industry in this research. Over 35% of the bottled water sold in the US is consumed in California where a third of the residents use such water as a primary source of drinking water. California is one of several states that regulates bottled water more rigorously than the federal government. In California, water quality standards for the two industries are comparable except that many of the organic standards for bottled water are applicable only to the source water,more » a concern due to potential organic contamination during processing. Reporting requirements, significantly less stringent for bottled water, allow considerable latitude in assessing risks and make assessment of compliance difficult. Based on available statistics, compliance for the two industries is comparable; the majority of violations posed no health risks. For both industries, small systems comprised the majority of violations whereas large systems had excellent compliance rates.« less

  9. Eliminating the use of intravenous glass bottles using a FOCUS-PDCA model and providing a practical stability reference guide.

    PubMed

    Maraiki, Fatma; Farooq, Faiyaz; Ahmed, Mohamed

    2016-08-01

    To identify the intravenous (IV) medications that are prepared in glass bottles at the institution and establish which of these medications can be prepared in flexible IV bags such as polyvinyl chloride (PVC) or non-PVC instead of glass bottles. The cost implication of switching from glass bottles to flexible IV bags was calculated. A study using FOCUS-PDCA model to identify IV medications prepared in glass bottles and establish which of these medications could be prepared in IV bags (PVC or non-PVC). The cost impact of switching from glass bottles to IV plastic bags (including PVC or non-PVC) was calculated. The stability data obtained were used as a reference for updating pharmacy internal IV preparation charts. A total of 17 IV medications were found to be prepared in IV glass bottles. Of these 17 medications, only 8 (47%) were prepared in IV glass bottles due to incompatibility with PVC bags. For 7 (41%) of the medications, of which 6 were monoclonal antibodies (MABs), the reason for preparation in glass bottles was unclear as these medications are compatible with either PVC or non-PVC or both. The potential cost savings associated with switching all of the identified medications to IV plastic bags (either non-PVC or PVC) exceeded $200 000. The elimination of glass bottles within the institution resulted in a significant cost saving. The use of FOCUS-PDCA model can help healthcare institution achieve significant improvements in process and realize significant cost savings. © 2016 Royal Pharmaceutical Society.

  10. Adaptation and evaluation of the bottle assay for monitoring insecticide resistance in disease vector mosquitoes in the Peruvian Amazon

    PubMed Central

    Zamora Perea, Elvira; Balta León, Rosario; Palomino Salcedo, Miriam; Brogdon, William G; Devine, Gregor J

    2009-01-01

    Background The purpose of this study was to establish whether the "bottle assay", a tool for monitoring insecticide resistance in mosquitoes, can complement and augment the capabilities of the established WHO assay, particularly in resource-poor, logistically challenging environments. Methods Laboratory reared Aedes aegypti and field collected Anopheles darlingi and Anopheles albimanus were used to assess the suitability of locally sourced solvents and formulated insecticides for use with the bottle assay. Using these adapted protocols, the ability of the bottle assay and the WHO assay to discriminate between deltamethrin-resistant Anopheles albimanus populations was compared. The diagnostic dose of deltamethrin that would identify resistance in currently susceptible populations of An. darlingi and Ae. aegypti was defined. The robustness of the bottle assay during a surveillance exercise in the Amazon was assessed. Results The bottle assay (using technical or formulated material) and the WHO assay were equally able to differentiate deltamethrin-resistant and susceptible An. albimanus populations. A diagnostic dose of 10 μg a.i./bottle was identified as the most sensitive discriminating dose for characterizing resistance in An. darlingi and Ae. aegypti. Treated bottles, prepared using locally sourced solvents and insecticide formulations, can be stored for > 14 days and used three times. Bottles can be stored and transported under local conditions and field-assays can be completed in a single evening. Conclusion The flexible and portable nature of the bottle assay and the ready availability of its components make it a potentially robust and useful tool for monitoring insecticide resistance and efficacy in remote areas that require minimal cost tools. PMID:19728871

  11. 27 CFR 5.41 - Bottle cartons, booklets and leaflets.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... TRADE BUREAU, DEPARTMENT OF THE TREASURY LIQUORS LABELING AND ADVERTISING OF DISTILLED SPIRITS Labeling...), or any written, printed, graphic, or other matter accompanying the bottle to the consumer buyer shall...

  12. The pet connection: pets as a conduit for social capital?

    PubMed

    Wood, Lisa; Giles-Corti, Billie; Bulsara, Max

    2005-09-01

    There is growing interest across a range of disciplines in the relationship between pets and health, with a range of therapeutic, physiological, psychological and psychosocial benefits now documented. While much of the literature has focused on the individual benefits of pet ownership, this study considered the potential health benefits that might accrue to the broader community, as encapsulated in the construct of social capital. A random survey of 339 adult residents from Perth, Western Australia were selected from three suburbs and interviewed by telephone. Pet ownership was found to be positively associated with some forms of social contact and interaction, and with perceptions of neighbourhood friendliness. After adjustment for demographic variables, pet owners scored higher on social capital and civic engagement scales. The results suggest that pet ownership provides potential opportunities for interactions between neighbours and that further research in this area is warranted. Social capital is another potential mechanism by which pets exert an influence on human health.

  13. [Reliability of % vol. declarations on labels of wine bottles].

    PubMed

    Schütz, Harald; Erdmann, Freidoon; Verhoff, Marcel A; Weiler, Günter

    2005-01-01

    The Council Regulation (EC) no. 1493/1999 of 17 May 1999 on the common organisation of the market in wine (Abl. L 179 dated 14/7/1999) and the GMO Wine 2000 (Annex VII A) stipulates that the labels of wine bottles have to indicate, among others, information on the sales designation of the product, the nominal volume and the alcoholic strength. The latter must not differ by more than 0.5% vol. from the alcoholic strength as established by analysis. Only when quality wines are stored in bottles for more than three years, the accepted tolerance limits are +/- 0.8% vol. The presented investigation results show that deviations have to be taken into account which may be highly relevant for forensic practice.

  14. Fluoride Content of Bottled Waters in Hong Kong and Qatar.

    PubMed

    Al-Mulla, Hessa I; Anthonappa, Robert P; King, Nigel M

    2016-01-01

    To determine the F concentration of bottled waters that was available in Hong Kong and Qatar. The F concentrations of bottled waters collected from Hong Kong (n=81) and Qatar (n=32) were analysed. The F ion selective electrode method was used to measure the F concentration in the samples. Three measurements were obtained for every sample to ensure reproducibility and appropriate statistical analyses were employed. Qatar group: F concentrations ranged from 0.06 ppm to 3.0 ppm with a mean value of 0.8 ppm. The F concentrations displayed on the labels of the samples (60%) were significantly lower than the measured F concentration (p < 0.0001). Hong Kong group: F concentrations ranged from 0.04 ppm to 2.52 ppm with a mean value of 0.44 ppm. The F concentrations displayed on the samples (16%) were significantly lower than the measured F concentration (p< 0.0001). Wide variations exist in the F concentration among the different brands of bottled water available in Hong Kong and Qatar. The F concentrations displayed on the labels were not consistent with the measured F concentrations.

  15. Veterinarians' role for pet owners facing pet loss

    PubMed Central

    Fernandez-Mehler, P.; Gloor, P.; Sager, E.; Lewis, F. I.; Glaus, T. M

    2013-01-01

    Owners' satisfaction with, and expectations from, their veterinarians around euthanasia, including questions on disposal of pet remains subject to animal species, clients' gender, age, family conditions, area of living and type of veterinary clinic visited were evaluated by questionnaire. Questionnaires were to be filled out by clients consecutively visiting the individual practices and hospitals for any kind of consultations. Of 2350 questionnaires distributed, 2008 were returned and available for analysis. Owner satisfaction concerning the procedure of euthanasia was high (92 per cent, 1173/1272). After the event of euthanasia, 14 per cent (170/1250) had changed their veterinarian, even though 75 per cent of these 170 had been satisfied with the procedure. Most owners (88 per cent) expected veterinarians to talk about their pet's final destination, and 38 per cent expected this to happen early in the pet's life. For 81 per cent clients, the veterinarian was the primary informant about the possibilities concerning the disposal of pet remains, and 33 per cent indicated their veterinarian as the contact person to talk about pet loss. Area of living, or veterinary specialisation, only marginally influenced the answers. Veterinarians play an important role to inform their clients concerning questions around euthanasia and the care of pet remains, and to support them during the process of mourning. PMID:23492929

  16. Magnetic Resonance-based Motion Correction for Quantitative PET in Simultaneous PET-MR Imaging.

    PubMed

    Rakvongthai, Yothin; El Fakhri, Georges

    2017-07-01

    Motion degrades image quality and quantitation of PET images, and is an obstacle to quantitative PET imaging. Simultaneous PET-MR offers a tool that can be used for correcting the motion in PET images by using anatomic information from MR imaging acquired concurrently. Motion correction can be performed by transforming a set of reconstructed PET images into the same frame or by incorporating the transformation into the system model and reconstructing the motion-corrected image. Several phantom and patient studies have validated that MR-based motion correction strategies have great promise for quantitative PET imaging in simultaneous PET-MR. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Sensory analysis of pet foods.

    PubMed

    Koppel, Kadri

    2014-08-01

    Pet food palatability depends first and foremost on the pet and is related to the pet food sensory properties such as aroma, texture and flavor. Sensory analysis of pet foods may be conducted by humans via descriptive or hedonic analysis, pets via acceptance or preference tests, and through a number of instrumental analysis methods. Sensory analysis of pet foods provides additional information on reasons behind palatable and unpalatable foods as pets lack linguistic capabilities. Furthermore, sensory analysis may be combined with other types of information such as personality and environment factors to increase understanding of acceptable pet foods. Most pet food flavor research is proprietary and, thus, there are a limited number of publications available. Funding opportunities for pet food studies would increase research and publications and this would help raise public awareness of pet food related issues. This mini-review addresses current pet food sensory analysis literature and discusses future challenges and possibilities. © 2014 Society of Chemical Industry.

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Causa, Andrea; Acierno, Domenico; Filippone, Giovanni

    We prepare and characterize multiphase systems in which small amounts of recycled polymer, namely polyethylene terephtalate (PET) ground from waste bottles, are dispersed in a co-continuous blend of high-density polyethylene (HDPE) and polypropylene (PP). Some of such ternary systems are also filled with plate-like clay nanoparticles with different polarities, in order to assess their influence on the morphology and mechanical behaviour of the blends. On the basis of preliminary wettability considerations and inspections by means of scanning electron microscopy (SEM), the PET is found to preferentially locate within the PP phase. Such a positioning is desirable in order to minimizemore » the presence of multiple interfaces, which is one of the major issues in the recycling process of co-mingles plastics. By means of SEM, dynamic-mechanical analysis and tensile tests we show that the addition of a filler with low polarity, which locates at the PET-matrix interface, has relevant implications on the structure and properties of the ternary systems, refining their morphology at the micro-scale and enhancing their high-temperature mechanical behaviour.« less

  19. Physicochemical quality and health implications of bottled water brands sold in Ethiopia.

    PubMed

    Amogne, Wossen T; Gizaw, Melaku; Abera, Daniel

    2015-06-01

    Water bottling companies often assert that their products are of the highest quality and are conforming to the standards. The objective of the study was to assess the physicochemical quality of bottled waters consumed in Ethiopia and to compare the findings with the national and international water quality standards. Eleven domestic and two imported bottled water brands were randomly purchased in Addis Ababa, Ethiopia at three different occasions from July 2013 to May 2014. A total of 39 composite samples were examined for aggregate parameters, major anions, and common cations in accordance with the procedures described in the standard methods. We found that 7.7% of the samples were containing higher levels of alkalinity, hardness, total dissolved solids, pH, HCO3-, Na+, and Ca2+ than the national standards and the WHO guidelines. However, the deviations from standards for all the above parameters were not statistically significant (one-sample t-test, P>0.05). Conversely, in some of the brands, some of the essential elements like Ca2+, K+, Mg2+, and F- were found at very low concentrations. The rest of the parameters, including CO3(2-), SO4(2-), PO4(3-) (orthophosphates), Cl-, F-, NO3-, NO2-, K+, Mg2+, Fe, Mn, Cr, Cd, Cu, Ni, and Pb were within the acceptable ranges in all the brands. Bottled water brands containing very high concentrations of dissolved substances may pose health risks for individuals living with heart and kidney related problems. On the other hand, brands having chemicals lower than the optimum level may also harm the health of consumers who choose those brands as a sole source of drinking water. Thus, we suggest those responsible authorities to ensure regular monitoring and testing for chemical compositions of bottled water.

  20. The Petit Rat (pet/pet), a New Semilethal Mutant Dwarf Rat with Thymic and Testicular Anomalies

    PubMed Central

    Chiba, Junko; Suzuki, Katsushi; Suzuki, Hiroetsu

    2008-01-01

    The petit rat (pet/pet) is a recently discovered semilethal mutant dwarf. The neonatal pet/pet rats had a low body weight and small thymus and testis. During the first 3 d after birth, 50% of the male and 80% of the female pet/pet pups were lost or found dead. Surviving pet/pet rats showed marked retardation of postnatal growth, and their body weights were 41% (female rats) and 32% (male rats) of those of normal rats at the adult stage. The pet/pet rats exhibited proportional dwarfism, and their longitudinal bones were shorter than those of controls without skeletal malformations. Most organs of male pet/pet rats, especially the thymus, testis, adipose tissue surrounding the kidney, and accessory sex organs, weighed markedly less at 140 d of age than did those of their normal counterparts. The thymus of pet/pet rats was small with abnormal thymic follicles. Testes from pet/pet rats exhibited 2 patterns of abnormal histology. Spermatogenesis was present in testes that were only slightly anomalous, but the seminiferous tubules were reduced in diameter. In severely affected testes, most of the seminiferous tubules showed degeneration, and interstitial tissue was increased. Plasma growth hormone concentrations did not differ between pet/pet and normal male rats. The dwarf phenotype of pet/pet rats was inherited as an autosomal recessive trait. These results indicate that the pet/pet rat has a semilethal growth-hormone-independent dwarf phenotype that is accompanied by thymic and testicular anomalies and low birth weight. PMID:19149412

  1. The petit rat (pet/pet), a new semilethal mutant dwarf rat with thymic and testicular anomalies.

    PubMed

    Chiba, Junko; Suzuki, Katsushi; Suzuki, Hiroetsu

    2008-12-01

    The petit rat (pet/pet) is a recently discovered semilethal mutant dwarf. The neonatal pet/pet rats had a low body weight and small thymus and testis. During the first 3 d after birth, 50% of the male and 80% of the female pet/pet pups were lost or found dead. Surviving pet/pet rats showed marked retardation of postnatal growth, and their body weights were 41% (female rats) and 32% (male rats) of those of normal rats at the adult stage. The pet/pet rats exhibited proportional dwarfism, and their longitudinal bones were shorter than those of controls without skeletal malformations. Most organs of male pet/pet rats, especially the thymus, testis, adipose tissue surrounding the kidney, and accessory sex organs, weighed markedly less at 140 d of age than did those of their normal counterparts. The thymus of pet/pet rats was small with abnormal thymic follicles. Testes from pet/pet rats exhibited 2 patterns of abnormal histology. Spermatogenesis was present in testes that were only slightly anomalous, but the seminiferous tubules were reduced in diameter. In severely affected testes, most of the seminiferous tubules showed degeneration, and interstitial tissue was increased. Plasma growth hormone concentrations did not differ between pet/pet and normal male rats. The dwarf phenotype of pet/pet rats was inherited as an autosomal recessive trait. These results indicate that the pet/pet rat has a semilethal growth-hormone-independent dwarf phenotype that is accompanied by thymic and testicular anomalies and low birth weight.

  2. Detection of antistripping additives with quick bottle test.

    DOT National Transportation Integrated Search

    1980-01-01

    Several variations of the quick bottle test were evaluated to determine the procedure having the best repeatability. Naphtha was selected over kerosene and white gas as the solvent for use in the test, and room temperature was selected over 140F as...

  3. Regulation and Education: Strategies for Solving the Bottle Feeding Problem. Monograph Series No. 4.

    ERIC Educational Resources Information Center

    Greiner, Ted

    This book is the fourth monograph in the Cornell International Monograph Series, the second in the series to deal with the question of breast versus bottle feeding. The introduction to the monograph discusses the shift from breast to bottle feeding in both industrialized and developing nations. Some of the reasons for, and consequences of, the…

  4. Influence of yeast strain, priming solution and temperature on beer bottle conditioning.

    PubMed

    Marconi, Ombretta; Rossi, Serena; Galgano, Fernanda; Sileoni, Valeria; Perretti, Giuseppe

    2016-09-01

    Recently, there has been a significant increase in the number of microbreweries. Usually, craft beers are bottle conditioned; however, few studies have investigated beer refermentation. One of the objectives of this study was to evaluate the impacts of different experimental conditions, specifically yeast strain, priming solution and temperature, on the standard quality attributes, the volatile compounds and the sensory profile of the bottle-conditioned beer. The other aim was to monitor the evolution of volatile compounds and amino acids consumption throughout the refermentation process to check if it is possible to reduce the time necessary for bottle conditioning. The results indicate that the volatile profile was mainly influenced by the strain of yeast, and this may have obscured the possible impacts of the other parameters. Our results also confirm that the two yeast strains showed different metabolic activity, particularly with respect to esters production. Moreover, we found the Safbrew S-33® strain when primed with Siromix® and refermented at 30 °C yielded the fastest formation of higher alcohols while maintaining low production of off-flavours. These results suggest a formulation that may reduce the time needed for bottle conditioning without affecting the quality of the final beer which may simultaneously improve efficiency and economic profits. © 2016 Society of Chemical Industry. © 2016 Society of Chemical Industry.

  5. Impact of bottled water storage duration and location on bacteriological quality.

    PubMed

    Duranceau, Steven J; Emerson, Hilary P; Wilder, Rebecca J

    2012-01-01

    An investigation studying the effects of storage duration and location on the persistence of heterotrophic microorganisms in oligotrophic bottled water environments has been completed. One-gallon high-density polyethylene water containers stored for up to 16 weeks at temperatures ranging from 2°C to >49°C in a refrigerator, indoor cabinet, covered porch, and car trunk were evaluated for microbiological quality. Heterotrophic plate counts (HPCs) of up to 4 × 10(3) cfu/mL were detected in containers stored on a porch and car trunk; whereas, HPCs were found not to exceed 400 cfu/mL and 100 cfu/mL for bottles stored in indoor cabinets and refrigerators, respectively. Containers stored on an enclosed porch for up to seven years contained HPC of up to 4 × 10(4) cfu/mL. Logistic and Gompertz growth models predicted microbial growth rates for bottled water stored on a protected porch environment for long (R(2) 0.99) and short-term (R(2) 0.86) durations.

  6. Waste water purification using new porous ceramics prepared by recycling waste glass and bamboo charcoal

    NASA Astrophysics Data System (ADS)

    Nishida, Tetsuaki; Morimoto, Akane; Yamamoto, Yoshito; Kubuki, Shiro

    2017-12-01

    New porous ceramics (PC) prepared by recycling waste glass bottle of soft drinks (80 mass%) and bamboo charcoal (20 mass%) without any binder was applied to the waste water purification under aeration at 25 °C. Artificial waste water (15 L) containing 10 mL of milk was examined by combining 15 mL of activated sludge and 750 g of PC. Biochemical oxygen demand (BOD) showed a marked decrease from 178 to 4.0 (±0.1) mg L-1 in 5 days and to 2.0 (±0.1) mg L-1 in 7 days, which was equal to the Environmental Standard for the river water (class A) in Japan. Similarly, chemical oxygen demand (COD) decreased from 158 to 3.6 (±0.1) mg L-1 in 5 days and to 2.2 (±0.1) mg L-1 in 9 days, which was less than the Environmental Standard for the Seawater (class B) in Japan: 3.0 mg L-1. These results prove the high water purification ability of the PC, which will be effectively utilized for the purification of drinking water, fish preserve water, fish farm water, etc.

  7. Pets for Handicapped Children.

    ERIC Educational Resources Information Center

    Frith, Greg H.

    1982-01-01

    Pets can provide valuable learning for handicapped children, but selection of a type of pet should consider cost, availability and care, parents' attitudes, locality, the animal's susceptibility to training, pet's life expectancy, and the child's handicap and emotional maturity. Suggested pet-related activities are listed. (CL)

  8. 40 CFR 141.101 - Use of bottled water.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 23 2011-07-01 2011-07-01 false Use of bottled water. 141.101 Section 141.101 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Use of Non-Centralized Treatment Devices § 141.101...

  9. 40 CFR 141.101 - Use of bottled water.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 22 2010-07-01 2010-07-01 false Use of bottled water. 141.101 Section 141.101 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Use of Non-Centralized Treatment Devices § 141.101...

  10. 40 CFR 141.101 - Use of bottled water.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 23 2014-07-01 2014-07-01 false Use of bottled water. 141.101 Section 141.101 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Use of Non-Centralized Treatment Devices § 141.101...

  11. 40 CFR 141.101 - Use of bottled water.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 24 2013-07-01 2013-07-01 false Use of bottled water. 141.101 Section 141.101 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Use of Non-Centralized Treatment Devices § 141.101...

  12. 40 CFR 141.101 - Use of bottled water.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 24 2012-07-01 2012-07-01 false Use of bottled water. 141.101 Section 141.101 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Use of Non-Centralized Treatment Devices § 141.101...

  13. Physicochemical and bacteriological quality of bottled drinking water in three sites of Amhara Regional State, Ethiopia.

    PubMed

    Biadglegne, Fantahun; Tessema, Belay; Kibret, Mulugeta; Abera, Bayeh; Huruy, Kahsay; Anagaw, Belay; Mulu, Andargachew

    2009-10-01

    The consumption of bottled drinking water is becoming increasing in Ethiopia. As a result there has been a growing concern about the chemical, physical and bacteriological quality of this product. Studies on the chemical, physical and bacteriological quality of bottled water is quite scarce in Ethiopia. This study was therefore aimed to assess the physicochemical and bacteriological qualities of three factories of bottled drinking water products produced in Amhara region. A Laboratory based comparative study was conducted to evaluate the physicochemical and bacteriological quality of three factories of bottled drinking water produced in Amhara region. Analysis on the quality of bottled drinking water from the sources, wholesalers and retailers were made with World Health Organization and Quality and Standards Authority of Ethiopia recommendations. Triplicate samples from three types of bottled drinking water were randomly collected and analyzed from June, 2006 to December, 2006. A total of 108 commercial bottled drinking water samples were analyzed. The result showed that except pH of factory A all the physicochemical parameters analyzed were with in the recommended limits. The pH value of factory A tested from sources is 5.3 and from wholesalers and retailers is 5.5 and 5.3, respectively, which is below the normal value set by World Health Organization (6.5-8.0) and Quality and Standards Authority of Ethiopia (6.0-8.5). Our analyses also demonstrated that 2 (16.7%) of the samples tested from sources and 1 (8.3%) from wholesalers of factory B were contaminated with total coliforms, where as 2 (16.7%) samples from retailers were also contaminated with total coliforms. On the other hand, 1 (8.3%) of the samples tested from wholesalers and 2 (16.7%) of the samples tested from retailers of factory A were also contaminated with total coliforms. Total coliforms were not detected from all samples of factory C, fecal coliforms were not also isolated from all samples

  14. Performance of composite sand cement brick containing recycle concrete aggregate and waste polyethylene terephthalate with different mix design ratio

    NASA Astrophysics Data System (ADS)

    Azmi, N. B.; Khalid, F. S.; Irwan, J. M.; Mazenan, P. N.; Zahir, Z.; Shahidan, S.

    2018-04-01

    This study is focuses to the performance of composite sand cement brick containing recycle concrete aggregate and waste polyethylene terephthalate. The objective is to determine the mechanical properties such as compressive strength and water absorption of composite brick containing recycled concrete aggregate and polyethylene terephthalate waste and to determine the optimum mix ratio of bricks containing recycled concrete aggregate and polyethylene terephthalate waste. The bricks specimens were prepared by using 100% natural sand, they were then replaced by RCA at 25%, 50% and 75% with proportions of PET consists of 1.0%, 1.5%, 2.0% and 2.5% by weight of natural sand. Based on the results of compressive strength, it indicates that the replacement of RCA shows an increasing strength as the strength starts to increase from 25% to 50% for both mix design ratio. The strength for RCA 75% volume of replacement started to decrease as the volume of PET increase. However, the result of water absorption with 50% RCA and 1.0% PET show less permeable compared to control brick at both mix design ratio. Thus, one would expect the density of brick decrease and the water absorption to increase as the RCA and PET content is increased.

  15. Effect of Fill Temperature on Clostridium botulinum Type A Toxin Activity during the Hot Filling of Juice Bottles.

    PubMed

    Skinner, Guy E; Fleischman, Gregory J; Balster, Fran; Reineke, Karl; Reddy, N Rukma; Larkin, John W

    2015-08-01

    The potential threat of terrorist attacks against the United States food supply using neurotoxin produced by Clostridium botulinum (BoNT) has resulted in the need for studying the effect of various food process operations on the bioavailability of this toxin. The objective of this study was to evaluate C. botulinum type A neurotoxin bioavailability after a simulated hot fill juice bottling operation. C. botulinum type A acid mud toxin (∼10(6) mouse lethal dose [MLD50]/ml) was deposited into juice bottles at an experimentally determined fastest cooling spot. Bottles (12 or 20 oz [355 and 592 ml]) were filled with either apple juice or an orange drink, at 80 or 85°C, in either upright or inverted orientations. Toxicity of the juice was evaluated as a function of holding time (1 to 2 min) by the mouse bioassay. The fastest cooling point in the upright orientation was determined to be at a bottle's bottom rim. In the inverted orientation, the fastest cooling point was in the bottle cap region. With respect to these two points, the upright bottle cooled faster than the inverted bottle, which was reflected in a higher inactivation of BoNT in the latter. For the orange drink (pH 2.9) toxicity was reduced by 0.5 × 10(6) MLD50/ml to a nondetectable level after 1 min in all bottle sizes, orientations, and temperatures as measured by the mouse bioassay. This indicates that there was at least a 0.5 × 10(6) MLD50/ml reduction in activity. Inactivation in apple juice (pH 4.0), to the same degree as in the orange drink, was found only for the inverted orientation at 85°C. Complete inactivation in apple juice for all conditions was found at a lower added toxin level of 0.25 × 10(5) MLD50/ml. In general, bottle inversion and filling at 85°C provided complete inactivation of BoNT to the 0.5 × 10(6) MLD50/ml level. All experiments resulted in the inactivation of 2.5 × 10(4) MLD50/ml of BoNT regardless of juice type, fill temperature, or bottle orientation and size.

  16. Screening of hormone-like activities in bottled waters available in Southern Spain using receptor-specific bioassays.

    PubMed

    Real, Macarena; Molina-Molina, José-Manuel; Jiménez-Díaz, Inmaculada; Arrebola, Juan Pedro; Sáenz, José-María; Fernández, Mariana F; Olea, Nicolás

    2015-01-01

    Bottled water consumption is a putative source of human exposure to endocrine-disrupting chemicals (EDCs). Research has been conducted on the presence of chemicals with estrogen-like activity in bottled waters and on their estrogenicity, but few data are available on the presence of hormonal activities associated with other nuclear receptors (NRs). The aim of this study was to determine the presence of endocrine activities dependent on the activation of human estrogen receptor alpha (hERa) and/or androgen receptor (hAR) in water in glass or plastic bottles sold to consumers in Southern Spain. Hormone-like activities were evaluated in 29 bottled waters using receptor-specific bioassays based on reporter gene expression in PALM cells [(anti-)androgenicity] and cell proliferation assessment in MCF-7 cells [(anti-)estrogenicity] after optimized solid phase extraction (SPE). All of the water samples analyzed showed hormonal activity. This was estrogenic in 79.3% and anti-estrogenic in 37.9% of samples and was androgenic in 27.5% and anti-androgenic in 41.3%, with mean concentrations per liter of 0.113pM 17β-estradiol (E2) equivalent units (E2Eq), 11.01pM anti-estrogen (ICI 182780) equivalent units (ICI 182780Eq), 0.33pM methyltrienolone (R1881) equivalent units (R1881Eq), and 0.18nM procymidone equivalent units (ProcEq). Bottled water consumption contributes to EDC exposure. Hormone-like activities observed in waters from both plastic and glass bottles suggest that plastic packaging is not the sole source of contamination and that the source of the water and bottling process may play a role, among other factors. Further research is warranted on the cumulative effects of long-term exposure to low doses of EDCs. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. Preference for tap, bottled, and recycled water: Relations to PTC taste sensitivity and personality.

    PubMed

    Harmon, Daniel; Gauvain, Mary; Z Reisz; Arthur, Isaac; Story, S Drew

    2018-02-01

    This study investigated people's preferences for different water sources and factors that predict such preferences using a blind taste test. Water preferences of 143 participants for one name-brand bottled water, one groundwater-sourced tap water, and one indirect potable reuse (IDR) water were assessed. For predictors of water preference, we measured each participant's PTC taste sensitivity and assessed two personality traits (Neuroticism, Openness to Experience). We also explored participants' descriptions of each water source. Results indicate a preference for water treated with Reverse Osmosis (RO) (bottled and IDR water) over groundwater-sourced water, which had higher pH levels and lower concentrations of Ca and HCO 3 - . PTC taste sensitivity did not predict preferences, while Openness to Experience and Neuroticism predicted preference for IDR water. Positive relations between Openness to Experience and preferences for bottled and IDR water were moderated by gender and were stronger among females. Participants described water primarily by its taste and texture. Findings suggest that (1) tap water treated by RO is equally preferable to some bottled water, (2) personality traits may affect water preferences, and (3) prior findings of gender differences in preferences for bottled water may reflect personality characteristics. Efforts to increase acceptance for sustainable water alternatives, such as IDR, may be more successful by assuring consumers about taste and addressing personality traits that encourage or inhibit use. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Basic study of entire whole-body PET scanners based on the OpenPET geometry

    NASA Astrophysics Data System (ADS)

    Yoshida, Eiji; Yamaya, Taiga; Nishikido, Fumihiko; Inadama, Naoko; Murayama, Hideo

    2010-09-01

    A conventional PET scanner has a 15-25 cm axial field-of-view (FOV) and images a whole body using about six bed positions. An OpenPET geometry can extend the axial FOV with a limited number of detectors. The entire whole-body PET scanner must be able to process a large amount of data effectively. In this work, we study feasibility of the fully 3D entire whole-body PET scanner using the GATE simulation. The OpenPET has 12 block detector rings with the ring diameter of 840 mm and each block detector ring consists of 48 depth-of-interaction (DOI) detectors. The OpenPET has the axial length of 895.95 mm with five parts of 58.95 mm open gaps. The OpenPET has higher single data loss than a conventional PET scanner at grouping circuits. NECR of the OpenPET decreases by single data loss. But single data loss is mitigated by separating the axially arranged detector into two parts. Also, multiple coincidences are found to be important for the entire whole-body PET scanner. The entire whole-body PET scanner with the OpenPET geometry promises to provide a large axial FOV with the open space and to have sufficient performance values. But single data loss at the grouping circuits and multiple coincidences are limited to the peak noise equivalent count rate (NECR) for the entire whole-body PET scanner.

  19. Presence of polychlorinated biphenyls (PCBs) in bottled drinking water in Mexico City.

    PubMed

    Salinas, Rutilio Ortiz; Bermudez, Beatriz Schettino; Tolentino, Rey Gutiérrez; Gonzalez, Gilberto Díaz; Vega y León, Salvador

    2010-10-01

    This paper describes the concentrations of seven polychlorinated biphenyls (PCBs) in bottled drinking water samples that were collected over 1 year from Mexico City in two sizes (1.5 and 19 L), using gas chromatography with an electron capture detector. PCBs 28 (0.018-0.042 μg/L), 52 (0.006-0.015 μg/L) and 101 (0.001-0.039 μg/L) were the most commonly found and were present in the majority of the samples. However, total concentrations of PCBs in bottled drinking water (0.035-0.039 μg/L) were below the maximum permissible level of 0.50 μg/L stated in Mexican regulations and probably do not represent a hazard to human health. PCBs were detectable in all samples and we recommend a monitoring program be established to better understand the quality of drinking bottled water over time; this may help in producing solutions for reducing the presence of organic contaminants.

  20. Raman and AFM study of gamma irradiated plastic bottle sheets

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ali, Yasir; Kumar, Vijay; Dhaliwal, A. S.

    2013-02-05

    In this investigation, the effects of gamma irradiation on the structural properties of plastic bottle sheet are studied. The Plastic sheets were exposed with 1.25MeV {sup 60}Co gamma rays source at various dose levels within the range from 0-670 kGy. The induced modifications were followed by micro-Raman and atomic force microscopy (AFM). The Raman spectrum shows the decrease in Raman intensity and formation of unsaturated bonds with an increase in the gamma dose. AFM image displays rough surface morphology after irradiation. The detailed Raman analysis of plastic bottle sheets is presented here, and the results are correlated with the AFMmore » observations.« less

  1. Chemical, microbial and physical evaluation of commercial bottled waters in greater Houston area of Texas.

    PubMed

    Saleh, Mahmoud A; Abdel-Rahman, Fawzia H; Woodard, Brooke B; Clark, Shavon; Wallace, Cecil; Aboaba, Adetoun; Zhang, Wenluo; Nance, James H

    2008-03-01

    Due to the increased demand and consumption of bottled water in the United States, there has been a growing concern about the quality of this product. Retail outlets sell local as well as imported bottled water to consumers. Three bottles for each of 35 different brands of bottled water were randomly collected from local grocery stores in the greater Houston area. Out of the 35 different brands, 16 were designated as spring water, 11 were purified and/or fortified tap water, 5 were carbonated water and 3 were distilled water. Chemical, microbial and physical properties of all samples were evaluated including pH, conductivity, bacteria counts, anion concentration, trace metal concentration, heavy metal and volatile organics concentration were determined in all samples. Inductively coupled plasma/mass spectrometry (ICPMS) was used for elemental analysis, gas chromatography with electron capture detector (GCECD) as well as gas chromatography mass spectrometry (GCMS) were used for analysis of volatile organics, ion chromatography (IC) and selective ion electrodes were used for the analysis of anions. Bacterial identification was performed using the Biolog software (Biolog, Inc., Hayward, Ca, USA). The results obtained were compared with guidelines of drinking water recommended by the International Bottled Water Association (IBWA), United States Food and Drug Administration (FDA), United States Environmental Protection Agency (EPA) and the World Health Organization (WHO) drinking water standard. The majority of the analyzed chemicals were below their respective drinking water standards for maximum admissible concentrations (MAC). Volatile organic chemicals were found to be below detection limits. Four of the 35 brands of the bottled water samples analyzed were found to be contaminated with bacteria.

  2. Gourds: Bitter, Bottle, Wax, Snake, Sponge and Ridge

    USDA-ARS?s Scientific Manuscript database

    Minor cucurbits include bitter gourd, bottle gourd, wax gourd, snake gourd, and sponge and ridge gourd, which are significant dietary sources of nutrients such as vitamin A and C, iron and calcium. These cucurbits are cultivated and marketed by smallholder farmers and remain important components of ...

  3. The Blue Bottle Experiment--Simple Demonstration of Self-Organization.

    ERIC Educational Resources Information Center

    Adamcikova, L'ubica; Sevcik, Peter

    1998-01-01

    Explains a way of observing pattern formation in the Blue Bottle chemistry demonstration by pouring a solution containing sodium hydroxide, glucose, and dye into a Petri dish and placing the dish on an overhead projector. (WRM)

  4. Childhood Attachment to Pets: Associations between Pet Attachment, Attitudes to Animals, Compassion, and Humane Behaviour

    PubMed Central

    Hawkins, Roxanne D.; Williams, Joanne M.

    2017-01-01

    Attachment to pets has an important role in children’s social, emotional, and cognitive development, mental health, well-being, and quality of life. This study examined associations between childhood attachment to pets and caring and friendship behaviour, compassion, and attitudes towards animals. This study also examined socio-demographic differences, particularly pet ownership and pet type. A self-report survey of over one thousand 7 to 12 year-olds in Scotland, UK, revealed that the majority of children are strongly attached to their pets, but attachment scores differ depending on pet type and child gender. Analysis revealed that attachment to pets is facilitated by compassion and caring and pet-directed friendship behaviours and that attachment to pets significantly predicts positive attitudes towards animals. The findings have implications for the promotion of prosocial and humane behaviour. Encouraging children to participate in pet care behaviour may promote attachment between children and their pet, which in turn may have a range of positive outcomes for both children (such as reduced aggression, better well-being, and quality of life) and pets (such as humane treatment). This study enhances our understanding of childhood pet attachment and has implications for humane education and promoting secure emotional attachments in childhood. PMID:28481256

  5. Childhood Attachment to Pets: Associations between Pet Attachment, Attitudes to Animals, Compassion, and Humane Behaviour.

    PubMed

    Hawkins, Roxanne D; Williams, Joanne M; Scottish Society For The Prevention Of Cruelty To Animals Scottish Spca

    2017-05-06

    Attachment to pets has an important role in children's social, emotional, and cognitive development, mental health, well-being, and quality of life. This study examined associations between childhood attachment to pets and caring and friendship behaviour, compassion, and attitudes towards animals. This study also examined socio-demographic differences, particularly pet ownership and pet type. A self-report survey of over one thousand 7 to 12 year-olds in Scotland, UK, revealed that the majority of children are strongly attached to their pets, but attachment scores differ depending on pet type and child gender. Analysis revealed that attachment to pets is facilitated by compassion and caring and pet-directed friendship behaviours and that attachment to pets significantly predicts positive attitudes towards animals. The findings have implications for the promotion of prosocial and humane behaviour. Encouraging children to participate in pet care behaviour may promote attachment between children and their pet, which in turn may have a range of positive outcomes for both children (such as reduced aggression, better well-being, and quality of life) and pets (such as humane treatment). This study enhances our understanding of childhood pet attachment and has implications for humane education and promoting secure emotional attachments in childhood.

  6. MALDI-TOF mass spectrometry for early identification of bacteria grown in blood culture bottles.

    PubMed

    Zabbe, Jean-Benoît; Zanardo, Laura; Mégraud, Francis; Bessède, Emilie

    2015-08-01

    This note reports an interesting way to rapidly identify bacteria grown from blood culture bottles. Chocolate agar plates were inoculated with 1 drop of the positive blood bottle medium. After a 3-hour incubation, the growth veil was submitted to MALDI-TOF mass spectrometry: 77% of the bacteria present have been correctly identified. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Pet Health

    MedlinePlus

    ... Before getting a pet, think carefully about which animal is best for your family. What is each ... Does anyone have pet allergies? What type of animal suits your lifestyle and budget? Once you own ...

  8. Quantitative and Visual Assessments toward Potential Sub-mSv or Ultrafast FDG PET Using High-Sensitivity TOF PET in PET/MRI.

    PubMed

    Behr, Spencer C; Bahroos, Emma; Hawkins, Randall A; Nardo, Lorenzo; Ravanfar, Vahid; Capbarat, Emily V; Seo, Youngho

    2018-06-01

    Newer high-performance time-of-flight (TOF) positron emission tomography (PET) systems have the capability to preserve diagnostic image quality with low count density, while maintaining a high raw photon detection sensitivity that would allow for a reduction in injected dose or rapid data acquisition. To assess this, we performed quantitative and visual assessments of the PET images acquired using a highly sensitive (23.3 cps/kBq) large field of view (25-cm axial) silicon photomultiplier (SiPM)-based TOF PET (400-ps timing resolution) integrated with 3 T-MRI in comparison to PET images acquired on non-TOF PET/x-ray computed tomography (CT) systems. Whole-body 2-deoxy-2-[ 18 F]fluoro-D-glucose ([ 18 F]FDG) PET/CT was acquired for 15 patients followed by whole body PET/magnetic resonance imaging (MRI) with an average injected dose of 325 ± 84 MBq. The PET list mode data from PET/MRI were reconstructed using full datasets (4 min/bed) and reduced datasets (2, 1, 0.5, and 0.25 min/bed). Qualitative assessment between PET/CT and PET/MR images were made. A Likert-type scale between 1 and 5, 1 for non-diagnostic, 3 equivalent to PET/CT, and 5 superior quality, was used. Maximum and mean standardized uptake values (SUV max and SUV mean ) of normal tissues and lesions detected were measured and compared. Mean visual assessment scores were 3.54 ± 0.32, 3.62 ± 0.38, and 3.69 ± 0.35 for the brain and 3.05 ± 0.49, 3.71 ± 0.45, and 4.14 ± 0.44 for the whole-body maximum intensity projections (MIPs) for 1, 2, and 4 min/bed PET/MR images, respectively. The SUV mean values for normal tissues were lower and statistically significant for images acquired at 4, 2, 1, 0.5, and 0.25 min/bed on the PET/MR, with values of - 18 ± 28 % (p < 0.001), - 16 ± 29 % (p = 0.001), - 16 ± 31 % (p = 0.002), - 14 ± 35 % (p < 0.001), and - 13 ± 34 % (p = 0.002), respectively. SUV max and SUV peak values of all lesions were

  9. Diagnostic performance of FDG PET or PET/CT in prosthetic infection after arthroplasty: a meta-analysis.

    PubMed

    Jin, H; Yuan, L; Li, C; Kan, Y; Hao, R; Yang, J

    2014-03-01

    The purpose of this study was to systematically review and perform a meta-analysis of published data regarding the diagnostic performance of positron emission tomography (PET) or PET/computed tomography (PET/CT) in prosthetic infection after arthroplasty. A comprehensive computer literature search of studies published through May 31, 2012 regarding PET or PET/CT in patients suspicious of prosthetic infection was performed in PubMed/MEDLINE, Embase and Scopus databases. Pooled sensitivity and specificity of PET or PET/CT in patients suspicious of prosthetic infection on a per prosthesis-based analysis were calculated. The area under the receiver-operating characteristic (ROC) curve was calculated to measure the accuracy of PET or PET/CT in patients with suspicious of prosthetic infection. Fourteen studies comprising 838 prosthesis with suspicious of prosthetic infection after arthroplasty were included in this meta-analysis. The pooled sensitivity of PET or PET/CT in detecting prosthetic infection was 86% (95% confidence interval [CI] 82-90%) on a per prosthesis-based analysis. The pooled specificity of PET or PET/CT in detecting prosthetic infection was 86% (95% CI 83-89%) on a per prosthesis-based analysis. The area under the ROC curve was 0.93 on a per prosthesis-based analysis. In patients suspicious of prosthetic infection, FDG PET or PET/CT demonstrated high sensitivity and specificity. FDG PET or PET/CT are accurate methods in this setting. Nevertheless, possible sources of false positive results and influcing factors should kept in mind.

  10. Clinical Significance of the Champagne Bottle Neck Sign in the Extracranial Carotid Arteries of Patients with Moyamoya Disease.

    PubMed

    Yasuda, C; Arakawa, S; Shimogawa, T; Kanazawa, Y; Sayama, T; Haga, S; Morioka, T

    2016-05-26

    The champagne bottle neck sign represents a rapid reduction in the extracranial ICA diameters and is a characteristic feature of Moyamoya disease. However, the clinical significance of the champagne bottle neck sign is unclear. We investigated the relationship between the champagne bottle neck sign and the clinical and hemodynamic stages of Moyamoya disease. We analyzed 14 patients with Moyamoya disease before revascularization (5 men, 9 women; age, 43.2 ± 19.3 years). The ratio of the extracranial ICA and common carotid artery diameters was determined using carotid ultrasonography or cerebral angiography; a ratio of < 0.5 was considered champagne bottle neck sign-positive. The clinical disease stage was determined using the Suzuki angiographic grading system. CBF and cerebral vasoreactivity also were measured. The ICA/common carotid artery ratio (expressed as median [interquartile range]) decreased as the clinical stage advanced (stages I-II, 0.71 [0.60-0.77]; stages III-IV, 0.49 [0.45-0.57]; stages V-VI, 0.38 [0.34-0.47]; P < .001). Lower ICA/common carotid artery ratio tended to occur in symptomatic versus asymptomatic arteries (0.47 [0.40-0.53] versus 0.57 [0.40-0.66], respectively; P = .06). Although the ICA/common carotid artery ratio was not related to cerebral perfusion, it decreased as cerebral vasoreactivity decreased (P < .01). All champagne bottle neck sign-positive arteries were classified as Suzuki stage ≥III, 73% were symptomatic, and 89% exhibited reduced cerebral vasoreactivity. In contrast, all champagne bottle neck sign-negative arteries were Suzuki stage ≤III, 67% were asymptomatic, and all showed preserved cerebral vasoreactivity. The champagne bottle neck sign was related to advanced clinical stage, clinical symptoms, and impaired cerebral vasoreactivity. Thus, detection of the champagne bottle neck sign might be useful in determining the clinical and hemodynamic stages of Moyamoya disease. © 2016 American Society of Neuroradiology.

  11. Comparison of BacT/Alert FAN and FAN Plus Bottles with Conventional Medium for Culturing Cerebrospinal Fluid.

    PubMed

    Yoo, In Young; Chun, Sejong; Song, Dong Joon; Huh, Hee Jae; Lee, Nam Yong

    2016-11-01

    We compared the BacT/Alert system FAN and FAN Plus media to conventional media for culturing cerebrospinal fluid (CSF) with 2,545 samples. FAN/FAN Plus bottles showed better performance for isolating microorganisms in CSF than conventional media (positive rate, 7.2% [182/2,545] versus 3.1% [80/2,545]). The incremental recovery rate of Cryptococcus neoformans from FAN Plus bottles was higher than that from FAN bottles. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  12. Design and Operation of Equipment to Detect and Remove Water within Used Nuclear Fuel Storage Bottles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    C.C. Baker; T.M. Pfeiffer; J.C. Price

    2013-09-01

    Inspection and drying equipment has been implemented in a hot cell to address the inadvertent ingress of water into used nuclear fuel storage bottles. Operated with telemanipulators, the system holds up to two fuel bottles and allows their threaded openings to be connected to pressure transducers and a vacuum pump. A prescribed pressure rebound test is used to diagnose the presence of moisture. Bottles found to contain moisture are dried by vaporization. The drying process is accelerated by the application of heat and vacuum. These techniques detect and remove virtually all free water (even water contained in a debris bed)more » while leaving behind most, if not all, particulates. The extracted water vapour passes through a thermoelectric cooler where it is condensed back to the liquid phase for collection. Fuel bottles are verified to be dry by passing the pressure rebound test.« less

  13. Is non-attenuation-corrected PET inferior to body attenuation-corrected PET or PET/CT in lung cancer?

    NASA Astrophysics Data System (ADS)

    Maintas, Dimitris; Houzard, Claire; Ksyar, Rachid; Mognetti, Thomas; Maintas, Catherine; Scheiber, Christian; Itti, Roland

    2006-12-01

    It is considered that one of the great strengths of PET imaging is the ability to correct for body attenuation. This enables better lesion uptake quantification and quality of PET images. The aim of this work is to compare the sensitivity of non-attenuation-corrected (NAC) PET images, the gamma photons (GPAC) and CT attenuation-corrected (CTAC) images in detecting and staging of lung cancer. We have studied 66 patients undergoing PET/CT examinations for detecting and staging NSC lung cancer. The patients were injected with 18-FDG; 5 MBq/kg under fasting conditions and examination was started 60 min later. Transmission data were acquired by a spiral CT X-ray tube and by gamma photons emitting Cs-137l source and were used for the patient body attenuation correction without correction for respiratory motion. In 55 of 66 patients we performed both attenuation correction procedures and in 11 patients only CT attenuation correction. In seven patients with solitary nodules PET was negative and in 59 patients with lung cancer PET/CT was positive for pulmonary or other localization. In the group of 55 patients we found 165 areas of focal increased 18-FDG uptake in NAC, 165 in CTAC and 164 in GPAC PET images.In the patients with only CTAC we found 58 areas of increased 18-FDG uptake on NAC and 58 areas lesions on CTAC. In the patients with positive PET we found 223 areas of focal increased uptake in NAC and 223 areas in CTAC images. The sensitivity of NAC was equal to the sensitivity of CTAC and GPAC images. The visualization of peripheral lesions was better in NAC images and the lesions were better localized in attenuation-corrected images. In three lesions of the thorax the localization was better in GPAC and fused images than in CTAC images.

  14. Putting Time in a Bottle--Or a Box!

    ERIC Educational Resources Information Center

    Turner, Thomas N.

    1989-01-01

    Discusses the problems of teaching time concepts to children. Suggests alternatives to the traditional time line. Describes the use of bottles and boxes as symbols of units of time when encouraging children to visualize and understand time. Provides information which will assist teachers in using these techniques. (KO)

  15. A DFT investigation of the blue bottle experiment: E∘half-cell analysis of autoxidation catalysed by redox indicators.

    PubMed

    Limpanuparb, Taweetham; Roongruangsree, Pakpong; Areekul, Cherprang

    2017-11-01

    The blue bottle experiment is a collective term for autoxidation reactions catalysed by redox indicators. The reactions are characterized by their repeatable cycle of colour changes when shaken/left to stand and intricate chemical pattern formation. The blue bottle experiment is studied based on calculated solution-phase half-cell reduction potential of related reactions. Our investigation confirms that the reaction in various versions of the blue bottle experiment published to date is mainly the oxidation of an acyloin to a 1,2-dicarbonyl structure. In the light of the calculations, we also propose new non-acyloin reducing agents for the experiment. These results can help guide future experimental studies on the blue bottle experiment.

  16. Effects of soda-lime-silica waste glass on mullite formation kinetics and micro-structures development in vitreous ceramics.

    PubMed

    Marinoni, Nicoletta; D'Alessio, Daniela; Diella, Valeria; Pavese, Alessandro; Francescon, Ferdinando

    2013-07-30

    The effects of soda-lime waste glass, from the recovery of bottle glass cullet, in partial replacement of Na-feldspar for sanitary-ware ceramic production are discussed. Attention is paid to the mullite growth kinetics and to the macroscopic properties of the final output, the latter ones depending on the developed micro-structures and vitrification grade. Measurements have been performed by in situ high temperature X-ray powder diffraction, scanning electron microscopy, thermal dilatometry, water absorption and mechanical testing. Glass substituting feldspar from 30 to 50 wt% allows one (i) to accelerate the mullite growth reaction kinetics, and (ii) to achieve macroscopic features of the ceramic output that comply with the latest technical requirements. The introduction of waste glass leads to (i) a general saving of fuel and reduction of the CO2-emissions during the firing stage, (ii) a preservation of mineral resources in terms of feldspars, and (iii) an efficient management of the bottle glass refuse by readdressing a part of it in the sanitary-ware manufacturing. Copyright © 2013 Elsevier Ltd. All rights reserved.

  17. Hybrid FDG-PET/MR compared to FDG-PET/CT in adult lymphoma patients.

    PubMed

    Atkinson, Wendy; Catana, Ciprian; Abramson, Jeremy S; Arabasz, Grae; McDermott, Shanaugh; Catalano, Onofrio; Muse, Victorine; Blake, Michael A; Barnes, Jeffrey; Shelly, Martin; Hochberg, Ephraim; Rosen, Bruce R; Guimaraes, Alexander R

    2016-07-01

    The goal of this study is to evaluate the diagnostic performance of simultaneous FDG-PET/MR including diffusion compared to FDG-PET/CT in patients with lymphoma. Eighteen patients with a confirmed diagnosis of non-Hodgkin's (NHL) or Hodgkin's lymphoma (HL) underwent an IRB-approved, single-injection/dual-imaging protocol consisting of a clinical FDG-PET/CT and subsequent FDG-PET/MR scan. PET images from both modalities were reconstructed iteratively. Attenuation correction was performed using low-dose CT data for PET/CT and Dixon-MR sequences for PET/MR. Diffusion-weighted imaging was performed. SUVmax was measured and compared between modalities and the apparent diffusion coefficient (ADC) using ROI analysis by an experienced radiologist using OsiriX. Strength of correlation between variables was measured using the Pearson correlation coefficient (r p). Of the 18 patients included in this study, 5 had HL and 13 had NHL. The median age was 51 ± 14.8 years. Sixty-five FDG-avid lesions were identified. All FDG-avid lesions were visible with comparable contrast, and therefore initial and follow-up staging was identical between both examinations. SUVmax from FDG-PET/MR [(mean ± sem) (21.3 ± 2.07)] vs. FDG-PET/CT (mean 23.2 ± 2.8) demonstrated a strongly positive correlation [r s = 0.95 (0.94, 0.99); p < 0.0001]. There was no correlation found between ADCmin and SUVmax from FDG-PET/MR [r = 0.17(-0.07, 0.66); p = 0.09]. FDG-PET/MR offers an equivalent whole-body staging examination as compared with PET/CT with an improved radiation safety profile in lymphoma patients. Correlation of ADC to SUVmax was weak, understating their lack of equivalence, but not undermining their potential synergy and differing importance.

  18. Fluoride content in bottled drinking waters, carbonated soft drinks and fruit juices in Davangere city, India.

    PubMed

    Thippeswamy, H M; Kumar, Nanditha; Anand, S R; Prashant, G M; Chandu, G N

    2010-01-01

    The regular ingestion of fluoride lowers the prevalence of dental caries. The total daily intake of fluoride for optimal dental health should be 0.05-0.07 mg fluoride/kg body weight and to avoid the risk of dental fluorosis, the daily intake should not exceed a daily level of 0.10 mg fluoride/kg body weight. The main source of fluoride is from drinking water and other beverages. As in other countries, consumption of bottled water, juices and carbonated beverages has increased in our country. To analyze the fluoride content in bottled water, juices and carbonated soft drinks that were commonly available in Davangere city. Three samples of 10 commercially available brands of bottled drinking water, 12 fruit juices and 12 carbonated soft drinks were purchased. Bottled water and carbonated soft drinks were stored at a cold place until fluoride analysis was performed and a clear juice was prepared using different fruits without the addition of water. Then, the fluoride analysis was performed. The mean and standard deviation of fluoride content of bottled water, fruit juices and carbonated soft drinks were measured, which were found to be 0.20 mg (±0.19) F/L, 0.29 mg (±0.06) F/L and 0.22 mg (±0.05) F/L, respectively. In viewing the results of the present study, it can be concluded that regulation of the optimal range of fluoride in bottled drinking water, carbonated soft drinks and fruit juices should be drawn for the Indian scenario.

  19. Linear and Nonlinear Elasticity of Networks Made of Comb-like Polymers and Bottle-Brushes

    NASA Astrophysics Data System (ADS)

    Liang, H.; Dobrynin, A.; Everhart, M.; Daniel, W.; Vatankhah-Varnoosfaderani, M.; Sheiko, S.

    We study mechanical properties of networks made of combs and bottle-brushes by computer simulations, theoretical calculations and experimental techniques. The networks are prepared by cross-linking backbones of combs or bottle-brushes with linear chains. This results in ``hybrid'' networks consisting of linear chains and strands of combs or bottle-brushes. In the framework of the phantom network model, the network modulus at small deformations G0 can be represented as a sum of contributions from linear chains, G0 , l, and strands of comb or bottle-brush, G0 , bb. If the length of extended backbone between crosslinks, Rmax, is much longer than the Kuhn length, bk, the modulus scales with the degree of polymerization of the side chains, nsc, and number of monomers between side chains, ng, as G0 , bb (nsc/ng + 1)-1. In the limit when bk becomes of the order of Rmax, the combs and bottle-brushes can be considered as semiflexible chains, resulting in a network modulus to be G0 , bb (nsc/ng + 1)-1(nsc2/2/ng) . In the nonlinear deformation regime, the strain-hardening behavior is described by the nonlinear network deformation model, which predicts that the true stress is a universal function of the structural modulus, G, first strain invariant, I1, and deformation ratio, β. The results of the computer simulations and predictions of the theoretical model are in a good agreement with experimental results. NSF DMR-1409710, DMR-1407645, DMR-1624569, DMR-1436201.

  20. Competitive Advantage of PET/MRI

    PubMed Central

    Jadvar, Hossein; Colletti, Patrick M.

    2013-01-01

    Multimodality imaging has made great strides in the imaging evaluation of patients with a variety of diseases. Positron emission tomography/computed tomography (PET/CT) is now established as the imaging modality of choice in many clinical conditions, particularly in oncology. While the initial development of combined PET/magnetic resonance imaging (PET/MRI) was in the preclinical arena, hybrid PET/MR scanners are now available for clinical use. PET/MRI combines the unique features of MRI including excellent soft tissue contrast, diffusion-weighted imaging, dynamic contrast-enhanced imaging, fMRI and other specialized sequences as well as MR spectroscopy with the quantitative physiologic information that is provided by PET. Most evidence for the potential clinical utility of PET/MRI is based on studies performed with side-by-side comparison or software-fused MRI and PET images. Data on distinctive utility of hybrid PET/MRI are rapidly emerging. There are potential competitive advantages of PET/MRI over PET/CT. In general, PET/MRI may be preferred over PET/CT where the unique features of MRI provide more robust imaging evaluation in certain clinical settings. The exact role and potential utility of simultaneous data acquisition in specific research and clinical settings will need to be defined. It may be that simultaneous PET/MRI will be best suited for clinical situations that are disease-specific, organ-specific, related to diseases of the children or in those patients undergoing repeated imaging for whom cumulative radiation dose must be kept as low as reasonably achievable. PET/MRI also offers interesting opportunities for use of dual modality probes. Upon clear definition of clinical utility, other important and practical issues related to business operational model, clinical workflow and reimbursement will also be resolved. PMID:23791129

  1. Competitive advantage of PET/MRI.

    PubMed

    Jadvar, Hossein; Colletti, Patrick M

    2014-01-01

    Multimodality imaging has made great strides in the imaging evaluation of patients with a variety of diseases. Positron emission tomography/computed tomography (PET/CT) is now established as the imaging modality of choice in many clinical conditions, particularly in oncology. While the initial development of combined PET/magnetic resonance imaging (PET/MRI) was in the preclinical arena, hybrid PET/MR scanners are now available for clinical use. PET/MRI combines the unique features of MRI including excellent soft tissue contrast, diffusion-weighted imaging, dynamic contrast-enhanced imaging, fMRI and other specialized sequences as well as MR spectroscopy with the quantitative physiologic information that is provided by PET. Most evidence for the potential clinical utility of PET/MRI is based on studies performed with side-by-side comparison or software-fused MRI and PET images. Data on distinctive utility of hybrid PET/MRI are rapidly emerging. There are potential competitive advantages of PET/MRI over PET/CT. In general, PET/MRI may be preferred over PET/CT where the unique features of MRI provide more robust imaging evaluation in certain clinical settings. The exact role and potential utility of simultaneous data acquisition in specific research and clinical settings will need to be defined. It may be that simultaneous PET/MRI will be best suited for clinical situations that are disease-specific, organ-specific, related to diseases of the children or in those patients undergoing repeated imaging for whom cumulative radiation dose must be kept as low as reasonably achievable. PET/MRI also offers interesting opportunities for use of dual modality probes. Upon clear definition of clinical utility, other important and practical issues related to business operational model, clinical workflow and reimbursement will also be resolved. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  2. Thermochemical Pretreatment for Anaerobic Digestion of Sorted Waste

    NASA Astrophysics Data System (ADS)

    Hao, W.; Hongtao, W.

    2008-02-01

    The effect of alkaline hydrothermal pre-treatment for anaerobic digestion of mechanically-sorted municipal solid waste (MSW) and source-sorted waste was studied. Waste was hydrothermally pre-treated in dilute alkali solution. Hydrolysis product was incubated in 500 ml saline bottle to determine methane potential (MP) under mesospheric anaerobic conditions. Optimum reaction condition obtained in the study is 170 °C at the dose of 4 g NaOH/100 g solid for one hour. Soluble COD was 13936 mg/L and methane yield was 164 ml/g VS for 6 days incubation at optimum conditions. More than 50% biogas increase was achieved over the control, and methane conversion ratio on carbon basis was enhanced to 30.6%. The digestion period was less than 6 days when pre-treatment temperature was above 130 °C. The organic part of sorted waste is mainly constituted of kitchen garbage and leaf. Model kitchen garbage was completely liquidized at 130 °C for one hour and the methane yield was 276 ml/g VS. Addition of alkali enhance hydroxylation rate and methane yield slightly. The biogas potential of leaf could be observed by pre-treatment above 150 °C under alkaline condition.

  3. Reproducibility of Quantitative Brain Imaging Using a PET-Only and a Combined PET/MR System

    PubMed Central

    Lassen, Martin L.; Muzik, Otto; Beyer, Thomas; Hacker, Marcus; Ladefoged, Claes Nøhr; Cal-González, Jacobo; Wadsak, Wolfgang; Rausch, Ivo; Langer, Oliver; Bauer, Martin

    2017-01-01

    The purpose of this study was to test the feasibility of migrating a quantitative brain imaging protocol from a positron emission tomography (PET)-only system to an integrated PET/MR system. Potential differences in both absolute radiotracer concentration as well as in the derived kinetic parameters as a function of PET system choice have been investigated. Five healthy volunteers underwent dynamic (R)-[11C]verapamil imaging on the same day using a GE-Advance (PET-only) and a Siemens Biograph mMR system (PET/MR). PET-emission data were reconstructed using a transmission-based attenuation correction (AC) map (PET-only), whereas a standard MR-DIXON as well as a low-dose CT AC map was applied to PET/MR emission data. Kinetic modeling based on arterial blood sampling was performed using a 1-tissue-2-rate constant compartment model, yielding kinetic parameters (K1 and k2) and distribution volume (VT). Differences for parametric values obtained in the PET-only and the PET/MR systems were analyzed using a 2-way Analysis of Variance (ANOVA). Comparison of DIXON-based AC (PET/MR) with emission data derived from the PET-only system revealed average inter-system differences of −33 ± 14% (p < 0.05) for the K1 parameter and −19 ± 9% (p < 0.05) for k2. Using a CT-based AC for PET/MR resulted in slightly lower systematic differences of −16 ± 18% for K1 and −9 ± 10% for k2. The average differences in VT were −18 ± 10% (p < 0.05) for DIXON- and −8 ± 13% for CT-based AC. Significant systematic differences were observed for kinetic parameters derived from emission data obtained from PET/MR and PET-only imaging due to different standard AC methods employed. Therefore, a transfer of imaging protocols from PET-only to PET/MR systems is not straightforward without application of proper correction methods. Clinical Trial Registration: www.clinicaltrialsregister.eu, identifier 2013-001724-19 PMID:28769742

  4. Feeding bottles usage and the prevalence of childhood allergy and asthma.

    PubMed

    Hsu, Nai-Yun; Wu, Pei-Chih; Bornehag, Carl-Gustaf; Sundell, Jan; Su, Huey-Jen

    2012-01-01

    This study aimed to examine the association between the length of use of feeding bottles or pacifiers during childhood and the prevalence of respiratory and allergic morbidities. A large-scale questionnaire survey was performed in day care centers and kindergartens (with children's ages ranging from 2 to 7 years) in southern Taiwan, and a total of 14,862 questionnaires completed by parents were finally recruited for data analysis. Effects of using feeding bottles on children's wheezing/asthma (adjusted OR: 1.05, 95% CI 1.00-1.09), allergic rhinitis (adjusted OR: 1.04, 95% CI 1.00-1.08), and eczema (adjusted OR: 1.07, 95% CI 1.01-1.2) were found. Moreover, significant dose-dependent relationships were further established after an adjustment for confounders was performed that included children's ages, gender, gestational age, birth weight, length of breastfeeding, the age when first given infant formula or complementary foods, family history, parental educational levels, and smoking status, as well as the problem of indoor water damage. This study was the first to reveal the potential risk of using plastic consumer products such as feeding bottles on the reported health status of preschool children in Asian countries.

  5. 27 CFR 4.38a - Bottle cartons, booklets and leaflets.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... TRADE BUREAU, DEPARTMENT OF THE TREASURY LIQUORS LABELING AND ADVERTISING OF WINE Labeling Requirements... written, printed, graphic, or other matter accompanying the bottle to the consumer buyer shall not contain...

  6. Evaluation of PeneloPET Simulations of Biograph PET/CT Scanners

    NASA Astrophysics Data System (ADS)

    Abushab, K. M.; Herraiz, J. L.; Vicente, E.; Cal-González, J.; España, S.; Vaquero, J. J.; Jakoby, B. W.; Udías, J. M.

    2016-06-01

    Monte Carlo (MC) simulations are widely used in positron emission tomography (PET) for optimizing detector design, acquisition protocols, and evaluating corrections and reconstruction methods. PeneloPET is a MC code based on PENELOPE, for PET simulations which considers detector geometry, acquisition electronics and materials, and source definitions. While PeneloPET has been successfully employed and validated with small animal PET scanners, it required a proper validation with clinical PET scanners including time-of-flight (TOF) information. For this purpose, we chose the family of Biograph PET/CT scanners: the Biograph True-Point (B-TP), Biograph True-Point with TrueV (B-TPTV) and the Biograph mCT. They have similar block detectors and electronics, but a different number of rings and configuration. Some effective parameters of the simulations, such as the dead-time and the size of the reflectors in the detectors, were adjusted to reproduce the sensitivity and noise equivalent count (NEC) rate of the B-TPTV scanner. These parameters were then used to make predictions of experimental results such as sensitivity, NEC rate, spatial resolution, and scatter fraction (SF), from all the Biograph scanners and some variations of them (energy windows and additional rings of detectors). Predictions agree with the measured values for the three scanners, within 7% (sensitivity and NEC rate) and 5% (SF). The resolution obtained for the B-TPTV is slightly better (10%) than the experimental values. In conclusion, we have shown that PeneloPET is suitable for simulating and investigating clinical systems with good accuracy and short computational time, though some effort tuning of a few parameters of the scanners modeled may be needed in case that the full details of the scanners studied are not available.

  7. Representing infant feeding: content analysis of British media portrayals of bottle feeding and breast feeding

    PubMed Central

    Henderson, Lesley; Kitzinger, Jenny; Green, Josephine

    2000-01-01

    Objective To examine how breast feeding and bottle feeding are represented by the British media. Design Content analysis. Subjects Television programmes and newspaper articles that made reference to infant feeding during March 1999. Setting UK mass media. Main outcome measures Visual and verbal references to breast or bottle feeding in newspapers and television programmes. Results Overall, 235 references to infant feeding were identified in the television sample and 38 in the newspaper sample. Bottle feeding was shown more often than breast feeding and was presented as less problematic. Bottle feeding was associated with “ordinary” families whereas breast feeding was associated with middle class or celebrity women. The health risks of formula milk and the health benefits of breast feeding were rarely mentioned. Conclusions The media rarely present positive information on breast feeding, even though this feeding practice is associated with the most health benefits. Health professionals and policy makers should be aware of patterns in media coverage and the cultural background within which women make decisions about infant feeding. PMID:11073512

  8. SU-F-I-57: Evaluate and Optimize PET Acquisition Overlap in 18F-FDG Oncology Wholebody PET/CT: Can We Scan PET Faster?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, J; Natwa, M; Hall, NC

    Purpose: The longer patient has to remain on the table during PET imaging, the higher the likelihood of motion artifacts due to patient discomfort. This study was to investigate and optimize PET acquisition overlap in 18F-FDG oncology wholebody PET/CT to speed up PET acquisition and improve patient comfort. Methods: Wholebody 18F-FDG PET/CT of phantoms, 8 pre-clinical patients (beagles) and 5 clinical oncology patients were performed in 90s/bed on a time-of-flight Gemini TF 64 system. Imaging of phantoms and beagles was acquired with reduced PET overlaps (40%, 33%, 27%, 20%, 13% and no overlap) in addition to the system default (53%).more » In human studies, 1 or 2 reduced overlaps from the listed options were used to acquire PET/CT sweeps right after the default standard of care imaging. Image quality was blindly reviewed using visual scoring criteria and quantitative SUV assessment. NEMA PET sensitivity was performed under different overlaps. Results: All PET exams demonstrated no significant impact on the visual grades for overlaps >20%. Blinded reviews assigned the best visual scores to PET using overlaps 53%–27%. Reducing overlap to 27% for oncology patients (12-bed) saved an average of ∼40% acquisition time (11min) compared to using the default overlap (18min). No significant SUV variances were found when reducing overlap to half of default for cerebellum, lung, heart, aorta, liver, fat, muscle, bone marrow, thighs and target lesions (p>0.05), except expected variability in urinary system. Conclusion: This study demonstrated by combined phantom, pre-clinical and clinical PET/CT scans that PET acquisition overlap in axial of today’s systems can be reduced and optimized. It showed that a reduction of PET acquisition overlap to 27% (half of system default) can be implemented to reduce table time by ∼40% to improve patient comfort and minimize potential motion artifacts, without prominently degrading image quality or compromising PET quantification.« less

  9. Avoidance of bottles during the establishment of breast feeds in preterm infants.

    PubMed

    Collins, Carmel T; Gillis, Jennifer; McPhee, Andrew J; Suganuma, Hiroki; Makrides, Maria

    2016-10-19

    Preterm infants start milk feeds by gavage tube. As they mature, sucking feeds are gradually introduced. Women who choose to breast feed their preterm infant are not always able to be in hospital with their baby and need an alternative approach to feeding. Most commonly, milk (expressed breast milk or formula) is given by bottle. Whether using bottles during establishment of breast feeds is detrimental to breast feeding success is a topic of ongoing debate. To identify the effects of avoidance of bottle feeds during establishment of breast feeding on the likelihood of successful breast feeding, and to assess the safety of alternatives to bottle feeds. We used the standard search strategy of the Cochrane Neonatal Review Group to search the Cochrane Central Register of Controlled Trials (CENTRAL; 2016, Issue 2), MEDLINE via PubMed (1966 to July 2016), Embase (1980 to July 2016) and CINAHL (1982 to July 2016). We also searched databases of clinical trials and the reference lists of retrieved articles for randomised controlled trials and quasi-randomised trials. Randomised and quasi-randomised controlled trials comparing avoidance of bottles with use of bottles in women who have chosen to breast feed their preterm infant. Two review authors independently assessed trial quality and extracted data. When appropriate, we contacted study authors for additional information. Review authors used standard methods of The Cochrane Collaboration and the Cochrane Neonatal Review Group. We included seven trials with 1152 preterm infants. Five studies used a cup feeding strategy, one used a tube feeding strategy and one used a novel teat when supplements to breast feeds were needed. We included the novel teat study in this review, as the teat was designed to more closely mimic the sucking action of breast feeding. The trials were of small to moderate size, and two had high risk of attrition bias. Adherence with cup feeding was poor in one of the studies, indicating dissatisfaction

  10. The spatial distribution of pet dogs and pet cats on the island of Ireland

    PubMed Central

    2011-01-01

    Background There is considerable international research regarding the link between human demographics and pet ownership. In several international studies, pet ownership was associated with household demographics including: the presence of children in the household, urban/rural location, level of education and age/family structure. What is lacking across all these studies, however, is an understanding of how these pets are spatially distributed throughout the regions under study. This paper describes the spatial distribution of pet dog and pet cat owning households on the island of Ireland. Results In 2006, there were an estimated 640,620 pet dog owning households and 215,542 pet cat owning households in Ireland. These estimates are derived from logistic regression modelling, based on household composition to determine pet dog ownership and the type of house to determine pet cat ownership. Results are presented using chloropleth maps. There is a higher density of pet dog owning households in the east of Ireland and in the cities than the west of Ireland and rural areas. However, in urban districts there are a lower proportion of households owning pet dogs than in rural districts. There are more households with cats in the urban areas, but the proportion of households with cats is greater in rural areas. Conclusions The difference in spatial distribution of dog ownership is a reflection of a generally higher density of households in the east of Ireland and in major cities. The higher proportion of ownership in the west is understandable given the higher proportion of farmers and rural dwellings in this area. Spatial representation allows us to visualise the impact of human household distribution on the density of both pet dogs and pet cats on the island of Ireland. This information can be used when analysing risk of disease spread, for market research and for instigating veterinary care. PMID:21663606

  11. The spatial distribution of pet dogs and pet cats on the island of Ireland.

    PubMed

    Downes, Martin J; Clegg, Tracy A; Collins, Daniel M; McGrath, Guy; More, Simon J

    2011-06-10

    There is considerable international research regarding the link between human demographics and pet ownership. In several international studies, pet ownership was associated with household demographics including: the presence of children in the household, urban/rural location, level of education and age/family structure. What is lacking across all these studies, however, is an understanding of how these pets are spatially distributed throughout the regions under study. This paper describes the spatial distribution of pet dog and pet cat owning households on the island of Ireland. In 2006, there were an estimated 640,620 pet dog owning households and 215,542 pet cat owning households in Ireland. These estimates are derived from logistic regression modelling, based on household composition to determine pet dog ownership and the type of house to determine pet cat ownership. Results are presented using chloropleth maps. There is a higher density of pet dog owning households in the east of Ireland and in the cities than the west of Ireland and rural areas. However, in urban districts there are a lower proportion of households owning pet dogs than in rural districts. There are more households with cats in the urban areas, but the proportion of households with cats is greater in rural areas. The difference in spatial distribution of dog ownership is a reflection of a generally higher density of households in the east of Ireland and in major cities. The higher proportion of ownership in the west is understandable given the higher proportion of farmers and rural dwellings in this area. Spatial representation allows us to visualise the impact of human household distribution on the density of both pet dogs and pet cats on the island of Ireland. This information can be used when analysing risk of disease spread, for market research and for instigating veterinary care.

  12. Analysis of microplastics in water by micro-Raman spectroscopy: Release of plastic particles from different packaging into mineral water.

    PubMed

    Schymanski, Darena; Goldbeck, Christophe; Humpf, Hans-Ulrich; Fürst, Peter

    2018-02-01

    Microplastics are anthropogenic contaminants which have been found in oceans, lakes and rivers. Investigations focusing on drinking water are rare and studies have mainly been using micro-Fourier Transform Infrared Spectroscopy (μ-FT-IR). A major limitation of this technique is its inability to detect particles smaller than 20 μm. However, micro-Raman spectroscopy is capable of detecting even smaller particle sizes. Therefore, we show that this technique, which was used in this study, is particularly useful in detecting microplastics in drinking water where particle sizes are in the low micrometer range. In our study, we compared the results from drinking water distributed in plastic bottles, glass bottles and beverage cartons. We tested the microplastic content of water from 22 different returnable and single-use plastic bottles, 3 beverage cartons and 9 glass bottles obtained from grocery stores in Germany. Small (-50-500 μm) and very small (1-50 μm) microplastic fragments were found in every type of water. Interestingly, almost 80% of all microplastic particles found had a particle size between 5 and 20 μm and were therefore not detectable by the analytical techniques used in previous studies. The average microplastics content was 118 ± 88 particles/l in returnable, but only 14 ± 14 particles/l in single-use plastic bottles. The microplastics content in the beverage cartons was only 11 ± 8 particles/l. Contrary to our assumptions we found high amounts of plastic particles in some of the glass bottled waters (range 0-253 particles/l, mean 50 ± 52 particles/l). A statistically significant difference from the blank value (14 ± 13) to the investigated packaging types could only be shown comparing to the returnable bottles (p < 0.05). Most of the particles in water from returnable plastic bottles were identified as consisting of polyester (primary polyethylene terephthalate PET, 84%) and polypropylene (PP; 7%). This is not surprising since

  13. 18F-FDG PET of the hands with a dedicated high-resolution PEM system (arthro-PET): correlation with PET/CT, radiography and clinical parameters.

    PubMed

    Mhlanga, Joyce C; Carrino, John A; Lodge, Martin; Wang, Hao; Wahl, Richard L

    2014-12-01

    The aim of this study was to prospectively determine the feasibility and compare the novel use of a positron emission mammography (PEM) scanner with standard PET/CT for evaluating hand osteoarthritis (OA) with (18)F-FDG. Institutional review board approval and written informed consent were obtained for this HIPAA-compliant prospective study in which 14 adults referred for oncological (18)F-FDG PET/CT underwent dedicated hand PET/CT followed by arthro-PET using the PEM device. Hand radiographs were obtained and scored for the presence and severity of OA. Summed qualitative and quantitative joint glycolytic scores for each modality were compared with the findings on plain radiography and clinical features. Eight patients with clinical and/or radiographic evidence of OA comprised the OA group (mean age 73 ± 7.7 years). Six patients served as the control group (53.7 ± 9.3 years). Arthro-PET quantitative and qualitative joint glycolytic scores were highly correlated with PET/CT findings in the OA patients (r = 0.86. p = 0.007; r = 0.94, p = 0.001). Qualitative arthro-PET and PET/CT joint scores were significantly higher in the OA patients than in controls (38.7 ± 6.6 vs. 32.2 ± 0.4, p = 0.02; 37.5 ± 5.4 vs. 32.2 ± 0.4, p = 0.03, respectively). Quantitative arthro-PET and PET/CT maximum SUV-lean joint scores were higher in the OA patients, although they did not reach statistical significance (20.8 ± 4.2 vs. 18 ± 1.8, p = 0.13; 22.8 ± 5.38 vs. 20.1 ± 1.54, p = 0.21). By definition, OA patients had higher radiographic joint scores than controls (30.9 ± 31.3 vs. 0, p = 0.03). Hand imaging using a small field of view PEM system (arthro-PET) with FDG is feasible, performing comparably to PET/CT in assessing metabolic joint activity. Arthro-PET and PET/CT showed higher joint FDG uptake in OA. Further exploration of arthro-PET in arthritis management is warranted.

  14. Evacuating People and Their Pets: Older Floridians' Need for and Proximity to Pet-Friendly Shelters.

    PubMed

    Douglas, Rachel; Kocatepe, Ayberk; Barrett, Anne E; Ozguven, Eren Erman; Gumber, Clayton

    2017-10-04

    Pets influence evacuation decisions, but little is known about pet-friendly emergency shelters' availability or older adults' need for them. Our study addresses this issue, focusing on the most densely populated area of Florida (Miami-Dade)-the state with the oldest population and greatest hurricane susceptibility. We use Geographic Information Systems (GIS)-based methodology to identify the shortest paths to pet-friendly shelters, based on distance and congested and uncongested travel times-taking into account the older population's spatial distribution. Logistic regression models using the 2013 American Housing Survey's Disaster Planning Module examine anticipated shelter use as a function of pet ownership and requiring pet evacuation assistance. Thirty-four percent of older adults in the Miami-Dade area have pets-35% of whom report needing pet evacuation assistance. However, GIS accessibility measures show that travel time factors are likely to impede older adults' use of the area's few pet-friendly shelters. Logistic regression results reveal that pet owners are less likely to report anticipating shelter use; however, the opposite holds for pet owners reporting they would need help evacuating their pets-they anticipate using shelters. High pet shelter need coupled with low availability exacerbates older adults' heightened vulnerability during Florida's hurricane season. © The Author 2017. Published by Oxford University Press on behalf of The Gerontological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  15. Solid waste recycling in Rajshahi city of Bangladesh.

    PubMed

    Bari, Q Hamidul; Hassan, K Mahbub; Haque, M Ehsanul

    2012-11-01

    Efficient recycling of solid wastes is now a global concern for a sustainable and environmentally sound management. In this study, traditional recycling pattern of solid waste was investigated in Rajshahi municipality which is the fourth largest city of Bangladesh. A questionnaire survey had been carried out in various recycle shops during April 2010 to January 2011. There were 140 recycle shops and most of them were located in the vicinity of Stadium market in Rajshahi. About 1906 people were found to be involved in recycling activities of the city. The major fraction of recycled wastes were sent to capital city Dhaka for further manufacture of different new products. Only a small amount of wastes, specially plastics, were processed in local recycle factories to produce small washing pots and bottle caps. Everyday, an estimated 28.13 tons of recycled solid wastes were handled in Rajshahi city area. This recycled portion accounted for 8.25% of the daily total generated wastes (341 ton d(-1)), 54.6% of total recyclable wastes (51.49 ton d(-1)) and 68.29% of readily recyclable wastes (41.19 ton d(-1)). Major recycled materials were found to be iron, glass, plastic, and papers. Only five factories were involved in preliminary processing of recyclable wastes. Collecting and processing secondary materials, manufacturing recycled-content products, and then buying recycled products created a circle or loop that ensured the overall success of recycling and generated a host of financial, environmental, and social returns. Copyright © 2012 Elsevier Ltd. All rights reserved.

  16. Active Site Flexibility as a Hallmark for Efficient PET Degradation by I. sakaiensis PETase.

    PubMed

    Fecker, Tobias; Galaz-Davison, Pablo; Engelberger, Felipe; Narui, Yoshie; Sotomayor, Marcos; Parra, Loreto P; Ramírez-Sarmiento, César A

    2018-03-27

    Polyethylene terephthalate (PET) is one of the most-consumed synthetic polymers, with an annual production of 50 million tons. Unfortunately, PET accumulates as waste and is highly resistant to biodegradation. Recently, fungal and bacterial thermophilic hydrolases were found to catalyze PET hydrolysis with optimal activities at high temperatures. Strikingly, an enzyme from Ideonella sakaiensis, termed PETase, was described to efficiently degrade PET at room temperature, but the molecular basis of its activity is not currently understood. Here, a crystal structure of PETase was determined at 2.02 Å resolution and employed in molecular dynamics simulations showing that the active site of PETase has higher flexibility at room temperature than its thermophilic counterparts. This flexibility is controlled by a novel disulfide bond in its active site, with its removal leading to destabilization of the catalytic triad and reduction of the hydrolase activity. Molecular docking of a model substrate predicts that PET binds to PETase in a unique and energetically favorable conformation facilitated by several residue substitutions within its active site when compared to other enzymes. These computational predictions are in excellent agreement with recent mutagenesis and PET film degradation analyses. Finally, we rationalize the increased catalytic activity of PETase at room temperature through molecular dynamics simulations of enzyme-ligand complexes for PETase and other thermophilic PET-degrading enzymes at 298, 323, and 353 K. Our results reveal that both the binding pose and residue substitutions within PETase favor proximity between the catalytic residues and the labile carbonyl of the substrate at room temperature, suggesting a more favorable hydrolytic reaction. These results are valuable for enabling detailed evolutionary analysis of PET-degrading enzymes and for rational design endeavors aiming at increasing the efficiency of PETase and similar enzymes toward plastic

  17. Local recurrence of prostate cancer after radical prostatectomy is at risk to be missed in 68Ga-PSMA-11-PET of PET/CT and PET/MRI: comparison with mpMRI integrated in simultaneous PET/MRI.

    PubMed

    Freitag, Martin T; Radtke, Jan P; Afshar-Oromieh, Ali; Roethke, Matthias C; Hadaschik, Boris A; Gleave, Martin; Bonekamp, David; Kopka, Klaus; Eder, Matthias; Heusser, Thorsten; Kachelriess, Marc; Wieczorek, Kathrin; Sachpekidis, Christos; Flechsig, Paul; Giesel, Frederik; Hohenfellner, Markus; Haberkorn, Uwe; Schlemmer, Heinz-Peter; Dimitrakopoulou-Strauss, A

    2017-05-01

    The positron emission tomography (PET) tracer 68 Ga-PSMA-11, targeting the prostate-specific membrane antigen (PSMA), is rapidly excreted into the urinary tract. This leads to significant radioactivity in the bladder, which may limit the PET-detection of local recurrence (LR) of prostate cancer (PC) after radical prostatectomy (RP), developing in close proximity to the bladder. Here, we analyze if there is additional value of multi-parametric magnetic resonance imaging (mpMRI) compared to the 68 Ga-PSMA-11-PET-component of PET/CT or PET/MRI to detect LR. One hundred and nineteen patients with biochemical recurrence after prior RP underwent both hybrid 68 Ga-PSMA-11-PET/CT low-dose (1 h p.i.) and -PET/MRI (2-3 h p.i.) including a mpMRI protocol of the prostatic bed. The comparison of both methods was restricted to the abdomen with focus on LR (McNemar). Bladder-LR distance and recurrence size were measured in axial T2w-TSE. A logistic regression was performed to determine the influence of these variables on detectability in 68 Ga-PSMA-11-PET. Standardized-uptake-value (SUV mean ) quantification of LR was performed. There were 93/119 patients that had at least one pathologic finding. In addition, 18/119 Patients (15.1%) were diagnosed with a LR in mpMRI of PET/MRI but only nine were PET-positive in PET/CT and PET/MRI. This mismatch was statistically significant (p = 0.004). Detection of LR using the PET-component was significantly influenced by proximity to the bladder (p = 0.028). The PET-pattern of LR-uptake was classified into three types (1): separated from bladder; (2): fuses with bladder, and (3): obliterated by bladder). The size of LRs did not affect PET-detectability (p = 0.84), mean size was 1.7 ± 0.69 cm long axis, 1.2 ± 0.46 cm short-axis. SUV mean in nine men was 8.7 ± 3.7 (PET/CT) and 7.0 ± 4.2 (PET/MRI) but could not be quantified in the remaining nine cases (obliterated by bladder). The present study demonstrates

  18. Bacteriophages safely reduce Salmonella contamination in pet food and raw pet food ingredients.

    PubMed

    Soffer, Nitzan; Abuladze, Tamar; Woolston, Joelle; Li, Manrong; Hanna, Leigh Farris; Heyse, Serena; Charbonneau, Duane; Sulakvelidze, Alexander

    2016-01-01

    Contamination of pet food with Salmonella is a serious public health concern, and several disease outbreaks have recently occurred due to human exposure to Salmonella tainted pet food. The problem is especially challenging for raw pet foods (which include raw meats, seafood, fruits, and vegetables). These foods are becoming increasingly popular because of their nutritional qualities, but they are also more difficult to maintain Salmonella -free because they lack heat-treatment. Among various methods examined to improve the safety of pet foods (including raw pet food), one intriguing approach is to use bacteriophages to specifically kill Salmonella serotypes. At least 2 phage preparations (SalmoFresh® and Salmonelex™) targeting Salmonella are already FDA cleared for commercial applications to improve the safety of human foods. However, similar preparations are not yet available for pet food applications. Here, we report the results of evaluating one such preparation (SalmoLyse®) in reducing Salmonella levels in various raw pet food ingredients (chicken, tuna, turkey, cantaloupe, and lettuce). Application of SalmoLyse® in low (ca. 2-4×10 6 PFU/g) and standard (ca. 9×10 6 PFU/g) concentrations significantly ( P < 0.01) reduced (by 60-92%) Salmonella contamination in all raw foods examined compared to control treatments. When SalmoLyse®-treated (ca. 2×10 7 PFU/g) dry pet food was fed to cats and dogs, it did not trigger any deleterious side effects in the pets. Our data suggest that the bacteriophage cocktail lytic for Salmonella can significantly and safely reduce Salmonella contamination in various raw pet food ingredients.

  19. The MiniPET: a didactic PET system

    NASA Astrophysics Data System (ADS)

    Pedro, R.; Silva, J.; Gurriana, L.; Silva, J. M.; Maio, A.; Soares Augusto, J.

    2013-03-01

    The MiniPET project aims to design and build a small PET system. It consists of two 4 × 4 matrices of 16 LYSO scintillator crystals and two PMTs with 16 channels resulting in a low cost system with the essential functionality of a clinical PET instrument. It is designed to illustrate the physics of the PET technique and to provide a didactic platform for the training of students and nuclear imaging professionals as well as for scientific outreach. The PET modules can be configured to test for the coincidence of 511 keV gamma rays. The model has a flexible mechanical setup [1] and can simulate 14 diferent ring geometries, from a configuration with as few as 18 detectors per ring (ring radius phi=51 mm), up to a geometry with 70 detectors per ring (phi=200 mm). A second version of the electronic system [2] allowed measurement and recording of the energy deposited in 4 detector channels by photons from a 137Cs radioactive source and by photons resulting of the annihilation of positrons from a 22Na radioactive source. These energy spectra are used for detector performance studies, as well as angular dependency studies. In this paper, the mechanical setup, the front-end high-speed analog electronics, the digital acquisition and control electronics implemented in a FPGA, as well as the data-transfer interface between the FPGA board and a host PC are described. Recent preliminary results obtained with the 4 active channels in the prototype are also presented.

  20. Molecular and Macromolecular Changes in Bottle-Aged White Wines Reflect Oxidative Evolution–Impact of Must Clarification and Bottle Closure

    PubMed Central

    Coelho, Christian; Julien, Perrine; Nikolantonaki, Maria; Noret, Laurence; Magne, Mathilde; Ballester, Jordi; Gougeon, Régis D.

    2018-01-01

    Chardonnay wines from Burgundy, obtained from musts with three levels of clarification (Low, Medium and High) during two consecutive vintages (2009 and 2010) and for two kinds of closures (screw caps and synthetic coextruded closures) were analyzed chemically and sensorially. Three bottles per turbidity level were opened in 2015 in order to assess the intensity of the reductive and/or oxidative aromas (REDOX sensory scores) by a trained sensory panel. The chemical analyses consisted in polyphenols and colloids quantification, followed by a proteomic characterization. For the two vintages, the REDOX sensory scores appeared to be driven both by the type of closure and to a lesser extent by the level of must clarification. Vintages and must racking prefermentative operations were also distinguished by chemical analyses. All white wines from the lowest must turbidity had the lowest REDOX sensory scores. Such wines exhibited lower concentrations in tyrosol and grape reaction product and higher concentrations in colloids with relatively low molecular weights. Among these macromolecules, grape proteins were also quantified, two of them exhibiting concentrations in bottled wines, which were statistically correlated to oxidative evolution in white wines. PMID:29682498

  1. Selected PET radiomic features remain the same.

    PubMed

    Tsujikawa, Tetsuya; Tsuyoshi, Hideaki; Kanno, Masafumi; Yamada, Shizuka; Kobayashi, Masato; Narita, Norihiko; Kimura, Hirohiko; Fujieda, Shigeharu; Yoshida, Yoshio; Okazawa, Hidehiko

    2018-04-17

    We investigated whether PET radiomic features are affected by differences in the scanner, scan protocol, and lesion location using 18 F-FDG PET/CT and PET/MR scans. SUV, TMR, skewness, kurtosis, entropy, and homogeneity strongly correlated between PET/CT and PET/MR images. SUVs were significantly higher on PET/MR 0-2 min and PET/MR 0-10 min than on PET/CT in gynecological cancer ( p = 0.008 and 0.008, respectively), whereas no significant difference was observed between PET/CT, PET/MR 0-2 min , and PET/MR 0-10 min images in oral cavity/oropharyngeal cancer. TMRs on PET/CT, PET/MR 0-2 min , and PET/MR 0-10 min increased in this order in gynecological cancer and oral cavity/oropharyngeal cancer. In contrast to conventional and histogram indices, 4 textural features (entropy, homogeneity, SRE, and LRE) were not significantly different between PET/CT, PET/MR 0-2 min , and PET/MR 0-10 min images. 18 F-FDG PET radiomic features strongly correlated between PET/CT and PET/MR images. Dixon-based attenuation correction on PET/MR images underestimated tumor tracer uptake more significantly in oral cavity/oropharyngeal cancer than in gynecological cancer. 18 F-FDG PET textural features were affected less by differences in the scanner and scan protocol than conventional and histogram features, possibly due to the resampling process using a medium bin width. Eight patients with gynecological cancer and 7 with oral cavity/oropharyngeal cancer underwent a whole-body 18 F-FDG PET/CT scan and regional PET/MR scan in one day. PET/MR scans were performed for 10 minutes in the list mode, and PET/CT and 0-2 min and 0-10 min PET/MR images were reconstructed. The standardized uptake value (SUV), tumor-to-muscle SUV ratio (TMR), skewness, kurtosis, entropy, homogeneity, short-run emphasis (SRE), and long-run emphasis (LRE) were compared between PET/CT, PET/MR 0-2 min , and PET/MR 0-10 min images.

  2. An Experimental Approach to Study Individual Differences in Infants' Intake and Satiation Behaviors during Bottle-Feeding.

    PubMed

    Ventura, Alison K; Mennella, Julie A

    2017-02-01

    As a group, bottle-fed infants are at higher risk for rapid weight gain compared with breast-fed infants. However, little is known about individual differences in feeding behaviors of bottle-feeding infants, as well as maternal and infant characteristics associated with bottle-feeding outcomes. We conducted a 2-day, within-subject study of 21 formula-feeding dyads; the within-subject factor was feeding condition: mother-led (ML; mothers were given the instruction to feed their infants as they typically would) vs. infant-led (IL; the experimenter ensured feeding began when infants signaled hunger and ended when they rejected the bottle on three consecutive occasions). Intake was determined by bottle weight; feedings were video-recorded and later analyzed to determine feeding duration and types of satiation behaviors displayed. Percent difference scores were calculated for each outcome as [((ML - IL)/IL) × 100] to standardize differences among dyads. Mothers completed questionnaires of feeding styles and infant temperament. On average, infants consumed ∼42% more formula during the ML- than IL-condition (p = 0.03). However, notable variation existed in difference scores for intake (range = -52.8% to 268.9%; higher scores reflect greater intake during ML than IL). Stepwise regression illustrated that greater intakes during the ML-condition were predicted by the combination of: (1) higher infant age; (2) lower levels of infant rhythmicity and adaptability; (3) higher levels of infant positive mood; and (4) lower levels of maternal restrictive and responsive feeding styles. This objective, experimental approach illustrated that variation in bottle-feeding outcomes is associated with characteristics of both members of the dyad.

  3. An Experimental Approach to Study Individual Differences in Infants' Intake and Satiation Behaviors during Bottle-Feeding

    PubMed Central

    Mennella, Julie A.

    2017-01-01

    Abstract Background: As a group, bottle-fed infants are at higher risk for rapid weight gain compared with breast-fed infants. However, little is known about individual differences in feeding behaviors of bottle-feeding infants, as well as maternal and infant characteristics associated with bottle-feeding outcomes. Methods: We conducted a 2-day, within-subject study of 21 formula-feeding dyads; the within-subject factor was feeding condition: mother-led (ML; mothers were given the instruction to feed their infants as they typically would) vs. infant-led (IL; the experimenter ensured feeding began when infants signaled hunger and ended when they rejected the bottle on three consecutive occasions). Intake was determined by bottle weight; feedings were video-recorded and later analyzed to determine feeding duration and types of satiation behaviors displayed. Percent difference scores were calculated for each outcome as [((ML – IL)/IL) × 100] to standardize differences among dyads. Mothers completed questionnaires of feeding styles and infant temperament. Results: On average, infants consumed ∼42% more formula during the ML- than IL-condition (p = 0.03). However, notable variation existed in difference scores for intake (range = −52.8% to 268.9%; higher scores reflect greater intake during ML than IL). Stepwise regression illustrated that greater intakes during the ML-condition were predicted by the combination of: (1) higher infant age; (2) lower levels of infant rhythmicity and adaptability; (3) higher levels of infant positive mood; and (4) lower levels of maternal restrictive and responsive feeding styles. Conclusions: This objective, experimental approach illustrated that variation in bottle-feeding outcomes is associated with characteristics of both members of the dyad. PMID:27788024

  4. Enhancement of PET Images

    NASA Astrophysics Data System (ADS)

    Davis, Paul B.; Abidi, Mongi A.

    1989-05-01

    PET is the only imaging modality that provides doctors with early analytic and quantitative biochemical assessment and precise localization of pathology. In PET images, boundary information as well as local pixel intensity are both crucial for manual and/or automated feature tracing, extraction, and identification. Unfortunately, the present PET technology does not provide the necessary image quality from which such precise analytic and quantitative measurements can be made. PET images suffer from significantly high levels of radial noise present in the form of streaks caused by the inexactness of the models used in image reconstruction. In this paper, our objective is to model PET noise and remove it without altering dominant features in the image. The ultimate goal here is to enhance these dominant features to allow for automatic computer interpretation and classification of PET images by developing techniques that take into consideration PET signal characteristics, data collection, and data reconstruction. We have modeled the noise steaks in PET images in both rectangular and polar representations and have shown both analytically and through computer simulation that it exhibits consistent mapping patterns. A class of filters was designed and applied successfully. Visual inspection of the filtered images show clear enhancement over the original images.

  5. Principles of PET/MR Imaging.

    PubMed

    Disselhorst, Jonathan A; Bezrukov, Ilja; Kolb, Armin; Parl, Christoph; Pichler, Bernd J

    2014-06-01

    Hybrid PET/MR systems have rapidly progressed from the prototype stage to systems that are increasingly being used in the clinics. This review provides an overview of developments in hybrid PET/MR systems and summarizes the current state of the art in PET/MR instrumentation, correction techniques, and data analysis. The strong magnetic field requires considerable changes in the manner by which PET images are acquired and has led, among others, to the development of new PET detectors, such as silicon photomultipliers. During more than a decade of active PET/MR development, several system designs have been described. The technical background of combined PET/MR systems is explained and related challenges are discussed. The necessity for PET attenuation correction required new methods based on MR data. Therefore, an overview of recent developments in this field is provided. Furthermore, MR-based motion correction techniques for PET are discussed, as integrated PET/MR systems provide a platform for measuring motion with high temporal resolution without additional instrumentation. The MR component in PET/MR systems can provide functional information about disease processes or brain function alongside anatomic images. Against this background, we point out new opportunities for data analysis in this new field of multimodal molecular imaging. © 2014 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  6. Exploring the Gas Chemistry of Old Submarine Technologies Using Plastic Bottles as Reaction Vessels and Models

    ERIC Educational Resources Information Center

    Horikoshi, Ryo; Takeiri, Fumitaka; Kobayashi, Yoji; Kageyama, Hiroshi

    2016-01-01

    We describe an activity that is suitable for high school students and makes use of plastic bottles. This activity allows students to familiarize themselves with gas chemistry by introducing technologies that were applied in old submarine systems. Plastic bottles, which are representative of submarines, are used as reaction vessels. Three simple…

  7. Clinical Nononcologic Applications of PET/CT and PET/MRI in Musculoskeletal, Orthopedic, and Rheumatologic Imaging.

    PubMed

    Gholamrezanezhad, Ali; Basques, Kyle; Batouli, Ali; Matcuk, George; Alavi, Abass; Jadvar, Hossein

    2018-06-01

    With improvements in PET/CT and PET/MRI over the last decade, as well as increased understanding of the pathophysiology of musculoskeletal diseases, there is an emerging potential for PET as a primary or complementary modality in the management of rheumatologic and orthopedic conditions. We discuss the role of PET/CT and PET/MRI in nononcologic musculoskeletal disorders, including inflammatory and infectious conditions and postoperative complications. There is great potential for an increased role for PET to serve as a primary or complementary modality in the management of orthopedic and rheumatologic disorders.

  8. 18F-FDG PET of the hands with a dedicated high-resolution PEM system (arthro-PET): correlation with PET/CT, radiography and clinical parameters

    PubMed Central

    Mhlanga, Joyce C.; Carrino, John A.; Lodge, Martin; Wang, Hao

    2015-01-01

    Purpose The aim of this study was to prospectively determine the feasibility and compare the novel use of a positron emission mammography (PEM) scanner with standard PET/CT for evaluating hand osteoarthritis (OA) with 18F-FDG. Methods Institutional review board approval and written informed consent were obtained for this HIPAA-compliant prospective study in which 14 adults referred for oncological 18F-FDG PET/CT underwent dedicated hand PET/CT followed by arthro-PET using the PEM device. Hand radiographs were obtained and scored for the presence and severity of OA. Summed qualitative and quantitative joint glycolytic scores for each modality were compared with the findings on plain radiography and clinical features. Results Eight patients with clinical and/or radiographic evidence of OA comprised the OA group (mean age 73±7.7 years). Six patients served as the control group (53.7±9.3 years). Arthro-PET quantitative and qualitative joint glycolytic scores were highly correlated with PET/CT findings in the OA patients (r=0.86. p =0.007; r=0.94, p=0.001). Qualitative arthro-PET and PET/CT joint scores were significantly higher in the OA patients than in controls (38.7±6.6 vs. 32.2±0.4, p=0.02; 37.5±5.4 vs. 32.2±0.4, p=0.03, respectively). Quantitative arthro-PET and PET/CT maximum SUV-lean joint scores were higher in the OA patients, although they did not reach statistical significance (20.8±4.2 vs. 18±1.8, p= 0.13; 22.8±5.38 vs. 20.1±1.54, p=0.21). By definition, OA patients had higher radiographic joint scores than controls (30.9±31.3 vs. 0, p=0.03). Conclusion Hand imaging using a small field of view PEM system (arthro-PET) with FDG is feasible, performing comparably to PET/CT in assessing metabolic joint activity. Arthro-PET and PET/CT showed higher joint FDG uptake in OA. Further exploration of arthro-PET in arthritis management is warranted. PMID:25134669

  9. Bacteriophages safely reduce Salmonella contamination in pet food and raw pet food ingredients

    PubMed Central

    Soffer, Nitzan; Abuladze, Tamar; Woolston, Joelle; Li, Manrong; Hanna, Leigh Farris; Heyse, Serena; Charbonneau, Duane; Sulakvelidze, Alexander

    2016-01-01

    ABSTRACT Contamination of pet food with Salmonella is a serious public health concern, and several disease outbreaks have recently occurred due to human exposure to Salmonella tainted pet food. The problem is especially challenging for raw pet foods (which include raw meats, seafood, fruits, and vegetables). These foods are becoming increasingly popular because of their nutritional qualities, but they are also more difficult to maintain Salmonella-free because they lack heat-treatment. Among various methods examined to improve the safety of pet foods (including raw pet food), one intriguing approach is to use bacteriophages to specifically kill Salmonella serotypes. At least 2 phage preparations (SalmoFresh® and Salmonelex™) targeting Salmonella are already FDA cleared for commercial applications to improve the safety of human foods. However, similar preparations are not yet available for pet food applications. Here, we report the results of evaluating one such preparation (SalmoLyse®) in reducing Salmonella levels in various raw pet food ingredients (chicken, tuna, turkey, cantaloupe, and lettuce). Application of SalmoLyse® in low (ca. 2–4×106 PFU/g) and standard (ca. 9×106 PFU/g) concentrations significantly (P < 0.01) reduced (by 60–92%) Salmonella contamination in all raw foods examined compared to control treatments. When SalmoLyse®-treated (ca. 2×107 PFU/g) dry pet food was fed to cats and dogs, it did not trigger any deleterious side effects in the pets. Our data suggest that the bacteriophage cocktail lytic for Salmonella can significantly and safely reduce Salmonella contamination in various raw pet food ingredients. PMID:27738557

  10. Artefacts of PET/CT images

    PubMed Central

    Pettinato, C; Nanni, C; Farsad, M; Castellucci, P; Sarnelli, A; Civollani, S; Franchi, R; Fanti, S; Marengo, M; Bergamini, C

    2006-01-01

    Positron emission tomography (PET) is a non-invasive imaging modality, which is clinically widely used both for diagnosis and accessing therapy response in oncology, cardiology and neurology. Fusing PET and CT images in a single dataset would be useful for physicians who could read the functional and the anatomical aspects of a disease in a single shot. The use of fusion software has been replaced in the last few years by integrated PET/CT systems, which combine a PET and a CT scanner in the same gantry. CT images have the double function to correct PET images for attenuation and can fuse with PET for a better visualization and localization of lesions. The use of CT for attenuation correction yields several advantages in terms of accuracy and patient comfort, but can also introduce several artefacts on PET-corrected images. PET/CT image artefacts are due primarily to metallic implants, respiratory motion, use of contrast media and image truncation. This paper reviews different types artefacts and their correction methods. PET/CT improves image quality and image accuracy. However, to avoid possible pitfalls the simultaneous display of both Computed Tomography Attenuation Corrected (CTAC) and non corrected PET images, side by side with CT images is strongly recommended. PMID:21614340

  11. Development of a PET Scanner for Simultaneously Imaging Small Animals with MRI and PET

    PubMed Central

    Thompson, Christopher J; Goertzen, Andrew L; Thiessen, Jonathan D; Bishop, Daryl; Stortz, Greg; Kozlowski, Piotr; Retière, Fabrice; Zhang, Xuezhu; Sossi, Vesna

    2014-01-01

    Recently, positron emission tomography (PET) is playing an increasingly important role in the diagnosis and staging of cancer. Combined PET and X-ray computed tomography (PET-CT) scanners are now the modality of choice in cancer treatment planning. More recently, the combination of PET and magnetic resonance imaging (MRI) is being explored in many sites. Combining PET and MRI has presented many challenges since the photo-multiplier tubes (PMT) in PET do not function in high magnetic fields, and conventional PET detectors distort MRI images. Solid state light sensors like avalanche photo-diodes (APDs) and more recently silicon photo-multipliers (SiPMs) are much less sensitive to magnetic fields thus easing the compatibility issues. This paper presents the results of a group of Canadian scientists who are developing a PET detector ring which fits inside a high field small animal MRI scanner with the goal of providing simultaneous PET and MRI images of small rodents used in pre-clinical medical research. We discuss the evolution of both the crystal blocks (which detect annihilation photons from positron decay) and the SiPM array performance in the last four years which together combine to deliver significant system performance in terms of speed, energy and timing resolution. PMID:25120157

  12. PET studies in epilepsy

    PubMed Central

    Sarikaya, Ismet

    2015-01-01

    Various PET studies, such as measurements of glucose, serotonin and oxygen metabolism, cerebral blood flow and receptor bindings are availabe for epilepsy. 18Fluoro-2-deoxyglucose (18F-FDG) PET imaging of brain glucose metabolism is a well established and widely available technique. Studies have demonstrated that the sensitivity of interictal FDG-PET is higher than interictal SPECT and similar to ictal SPECT for the lateralization and localization of epileptogenic foci in presurgical patients refractory to medical treatments who have noncontributory EEG and MRI. In addition to localizing epileptogenic focus, FDG-PET provide additional important information on the functional status of the rest of the brain. The main limitation of interictal FDG-PET is that it cannot precisely define the surgical margin as the area of hypometabolism usually extends beyond the epileptogenic zone. Various neurotransmitters (GABA, glutamate, opiates, serotonin, dopamine, acethylcholine, and adenosine) and receptor subtypes are involved in epilepsy. PET receptor imaging studies performed in limited centers help to understand the role of neurotransmitters in epileptogenesis, identify epileptic foci and investigate new treatment approaches. PET receptor imaging studies have demonstrated reduced 11C-flumazenil (GABAA-cBDZ) and 18F-MPPF (5-HT1A serotonin) and increased 11C-cerfentanil (mu opiate) and 11C-MeNTI (delta opiate) bindings in the area of seizure. 11C-flumazenil has been reported to be more sensitive than FDG-PET for identifying epileptic foci. The area of abnormality on GABAAcBDZ and opiate receptor images is usually smaller and more circumscribed than the area of hypometabolism on FDG images. Studies have demonstrated that 11C-alpha-methyl-L-tryptophan PET (to study synthesis of serotonin) can detect the epileptic focus within malformations of cortical development and helps in differentiating epileptogenic from non-epileptogenic tubers in patients with tuberous sclerosis complex

  13. Optimization of a shorter variable-acquisition time for legs to achieve true whole-body PET/CT images.

    PubMed

    Umeda, Takuro; Miwa, Kenta; Murata, Taisuke; Miyaji, Noriaki; Wagatsuma, Kei; Motegi, Kazuki; Terauchi, Takashi; Koizumi, Mitsuru

    2017-12-01

    The present study aimed to qualitatively and quantitatively evaluate PET images as a function of acquisition time for various leg sizes, and to optimize a shorter variable-acquisition time protocol for legs to achieve better qualitative and quantitative accuracy of true whole-body PET/CT images. The diameters of legs to be modeled as phantoms were defined based on data derived from 53 patients. This study analyzed PET images of a NEMA phantom and three plastic bottle phantoms (diameter, 5.68, 8.54 and 10.7 cm) that simulated the human body and legs, respectively. The phantoms comprised two spheres (diameters, 10 and 17 mm) containing fluorine-18 fluorodeoxyglucose solution with sphere-to-background ratios of 4 at a background radioactivity level of 2.65 kBq/mL. All PET data were reconstructed with acquisition times ranging from 10 to 180, and 1200 s. We visually evaluated image quality and determined the coefficient of variance (CV) of the background, contrast and the quantitative %error of the hot spheres, and then determined two shorter variable-acquisition protocols for legs. Lesion detectability and quantitative accuracy determined based on maximum standardized uptake values (SUV max ) in PET images of a patient using the proposed protocols were also evaluated. A larger phantom and a shorter acquisition time resulted in increased background noise on images and decreased the contrast in hot spheres. A visual score of ≥ 1.5 was obtained when the acquisition time was ≥ 30 s for three leg phantoms, and ≥ 120 s for the NEMA phantom. The quantitative %errors of the 10- and 17-mm spheres in the leg phantoms were ± 15 and ± 10%, respectively, in PET images with a high CV (scan < 30 s). The mean SUV max of three lesions using the current fixed-acquisition and two proposed variable-acquisition time protocols in the clinical study were 3.1, 3.1 and 3.2, respectively, which did not significantly differ. Leg acquisition time per bed position of

  14. The ADNI PET Core: 2015

    PubMed Central

    Jagust, William J.; Landau, Susan M.; Koeppe, Robert A.; Reiman, Eric M.; Chen, Kewei; Mathis, Chester A.; Price, Julie C.; Foster, Norman L.; Wang, Angela Y.

    2015-01-01

    INTRODUCTION This paper reviews the work done in the ADNI PET core over the past 5 years, largely concerning techniques, methods, and results related to amyloid imaging in ADNI. METHODS The PET Core has utilized [18F]florbetapir routinely on ADNI participants, with over 1600 scans available for download. Four different laboratories are involved in data analysis, and have examined factors such as longitudinal florbetapir analysis, use of FDG-PET in clinical trials, and relationships between different biomarkers and cognition. RESULTS Converging evidence from the PET Core has indicated that cross-sectional and longitudinal florbetapir analyses require different reference regions. Studies have also examined the relationship between florbetapir data obtained immediately after injection, which reflects perfusion, and FDG-PET results. Finally, standardization has included the translation of florbetapir PET data to a centiloid scale. CONCLUSION The PET Core has demonstrated a variety of methods for standardization of biomarkers such as florbetapir PET in a multicenter setting. PMID:26194311

  15. PET-Tool: a software suite for comprehensive processing and managing of Paired-End diTag (PET) sequence data.

    PubMed

    Chiu, Kuo Ping; Wong, Chee-Hong; Chen, Qiongyu; Ariyaratne, Pramila; Ooi, Hong Sain; Wei, Chia-Lin; Sung, Wing-Kin Ken; Ruan, Yijun

    2006-08-25

    We recently developed the Paired End diTag (PET) strategy for efficient characterization of mammalian transcriptomes and genomes. The paired end nature of short PET sequences derived from long DNA fragments raised a new set of bioinformatics challenges, including how to extract PETs from raw sequence reads, and correctly yet efficiently map PETs to reference genome sequences. To accommodate and streamline data analysis of the large volume PET sequences generated from each PET experiment, an automated PET data process pipeline is desirable. We designed an integrated computation program package, PET-Tool, to automatically process PET sequences and map them to the genome sequences. The Tool was implemented as a web-based application composed of four modules: the Extractor module for PET extraction; the Examiner module for analytic evaluation of PET sequence quality; the Mapper module for locating PET sequences in the genome sequences; and the Project Manager module for data organization. The performance of PET-Tool was evaluated through the analyses of 2.7 million PET sequences. It was demonstrated that PET-Tool is accurate and efficient in extracting PET sequences and removing artifacts from large volume dataset. Using optimized mapping criteria, over 70% of quality PET sequences were mapped specifically to the genome sequences. With a 2.4 GHz LINUX machine, it takes approximately six hours to process one million PETs from extraction to mapping. The speed, accuracy, and comprehensiveness have proved that PET-Tool is an important and useful component in PET experiments, and can be extended to accommodate other related analyses of paired-end sequences. The Tool also provides user-friendly functions for data quality check and system for multi-layer data management.

  16. PeneloPET, a Monte Carlo PET simulation tool based on PENELOPE: features and validation

    NASA Astrophysics Data System (ADS)

    España, S; Herraiz, J L; Vicente, E; Vaquero, J J; Desco, M; Udias, J M

    2009-03-01

    Monte Carlo simulations play an important role in positron emission tomography (PET) imaging, as an essential tool for the research and development of new scanners and for advanced image reconstruction. PeneloPET, a PET-dedicated Monte Carlo tool, is presented and validated in this work. PeneloPET is based on PENELOPE, a Monte Carlo code for the simulation of the transport in matter of electrons, positrons and photons, with energies from a few hundred eV to 1 GeV. PENELOPE is robust, fast and very accurate, but it may be unfriendly to people not acquainted with the FORTRAN programming language. PeneloPET is an easy-to-use application which allows comprehensive simulations of PET systems within PENELOPE. Complex and realistic simulations can be set by modifying a few simple input text files. Different levels of output data are available for analysis, from sinogram and lines-of-response (LORs) histogramming to fully detailed list mode. These data can be further exploited with the preferred programming language, including ROOT. PeneloPET simulates PET systems based on crystal array blocks coupled to photodetectors and allows the user to define radioactive sources, detectors, shielding and other parts of the scanner. The acquisition chain is simulated in high level detail; for instance, the electronic processing can include pile-up rejection mechanisms and time stamping of events, if desired. This paper describes PeneloPET and shows the results of extensive validations and comparisons of simulations against real measurements from commercial acquisition systems. PeneloPET is being extensively employed to improve the image quality of commercial PET systems and for the development of new ones.

  17. Feeding Bottles Usage and the Prevalence of Childhood Allergy and Asthma

    PubMed Central

    Hsu, Nai-Yun; Wu, Pei-Chih; Bornehag, Carl-Gustaf; Sundell, Jan; Su, Huey-Jen

    2012-01-01

    This study aimed to examine the association between the length of use of feeding bottles or pacifiers during childhood and the prevalence of respiratory and allergic morbidities. A large-scale questionnaire survey was performed in day care centers and kindergartens (with children's ages ranging from 2 to 7 years) in southern Taiwan, and a total of 14,862 questionnaires completed by parents were finally recruited for data analysis. Effects of using feeding bottles on children's wheezing/asthma (adjusted OR: 1.05, 95% CI 1.00–1.09), allergic rhinitis (adjusted OR: 1.04, 95% CI 1.00–1.08), and eczema (adjusted OR: 1.07, 95% CI 1.01–1.2) were found. Moreover, significant dose-dependent relationships were further established after an adjustment for confounders was performed that included children's ages, gender, gestational age, birth weight, length of breastfeeding, the age when first given infant formula or complementary foods, family history, parental educational levels, and smoking status, as well as the problem of indoor water damage. This study was the first to reveal the potential risk of using plastic consumer products such as feeding bottles on the reported health status of preschool children in Asian countries. PMID:22291844

  18. Prediction of ethanol in bottled Chinese rice wine by NIR spectroscopy

    NASA Astrophysics Data System (ADS)

    Ying, Yibin; Yu, Haiyan; Pan, Xingxiang; Lin, Tao

    2006-10-01

    To evaluate the applicability of non-invasive visible and near infrared (VIS-NIR) spectroscopy for determining ethanol concentration of Chinese rice wine in square brown glass bottle, transmission spectra of 100 bottled Chinese rice wine samples were collected in the spectral range of 350-1200 nm. Statistical equations were established between the reference data and VIS-NIR spectra by partial least squares (PLS) regression method. Performance of three kinds of mathematical treatment of spectra (original spectra, first derivative spectra and second derivative spectra) were also discussed. The PLS models of original spectra turned out better results, with higher correlation coefficient in calibration (R cal) of 0.89, lower root mean standard error of calibration (RMSEC) of 0.165, and lower root mean standard error of cross validation (RMSECV) of 0.179. Using original spectra, PLS models for ethanol concentration prediction were developed. The R cal and the correlation coefficient in validation (R val) were 0.928 and 0.875, respectively; and the RMSEC and the root mean standard error of validation (RMSEP) were 0.135 (%, v v -1) and 0.177 (%, v v -1), respectively. The results demonstrated that VIS-NIR spectroscopy could be used to predict ethanol concentration in bottled Chinese rice wine.

  19. Evaluating pet foods: how confident are you when you recommend a commercial pet food?

    PubMed

    Zicker, Steven C

    2008-08-01

    The safety, adequacy, and efficacy of pet foods are important considerations for veterinarians and consumers. Manufacturers of pet foods in the United States are required to comply with multiple regulations from a variety of governmental and state agencies to market foods in the public sector. However, consumers and veterinarians may not be aware of the multiple systems in place that help ensure the safety and adequacy of foods for their pets. Since the veterinarian occupies a key role to make recommendations to consumers regarding pet foods, it is the purpose of this article to review the processes of pet food manufacturing, as well as the processes that have been developed to help ensure safety and adequacy of pet foods in the United States.

  20. 27 CFR 19.638 - Disposition of stocks of liquor bottles.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... stocks of such bottles on hand shall either be disposed of to another person authorized to receive liquor.... However, on approval of a written application by the appropriate TTB officer of the region in which the...