Sample records for wastewater outlet cold

  1. Wastewater heat recovery apparatus

    DOEpatents

    Kronberg, James W.

    1992-01-01

    A heat recovery system with a heat exchanger and a mixing valve. A drain trap includes a heat exchanger with an inner coiled tube, baffle plate, wastewater inlet, wastewater outlet, cold water inlet, and preheated water outlet. Wastewater enters the drain trap through the wastewater inlet, is slowed and spread by the baffle plate, and passes downward to the wastewater outlet. Cold water enters the inner tube through the cold water inlet and flows generally upward, taking on heat from the wastewater. This preheated water is fed to the mixing valve, which includes a flexible yoke to which are attached an adjustable steel rod, two stationary zinc rods, and a pivoting arm. The free end of the arm forms a pad which rests against a valve seat. The rods and pivoting arm expand or contract as the temperature of the incoming preheated water changes. The zinc rods expand more than the steel rod, flexing the yoke and rotating the pivoting arm. The pad moves towards the valve seat as the temperature of the preheated water rises, and away as the temperature falls, admitting a variable amount of hot water to maintain a nearly constant average process water temperature.

  2. Wastewater heat recovery apparatus

    DOEpatents

    Kronberg, J.W.

    1992-09-01

    A heat recovery system is described with a heat exchanger and a mixing valve. A drain trap includes a heat exchanger with an inner coiled tube, baffle plate, wastewater inlet, wastewater outlet, cold water inlet, and preheated water outlet. Wastewater enters the drain trap through the wastewater inlet, is slowed and spread by the baffle plate, and passes downward to the wastewater outlet. Cold water enters the inner tube through the cold water inlet and flows generally upward, taking on heat from the wastewater. This preheated water is fed to the mixing valve, which includes a flexible yoke to which are attached an adjustable steel rod, two stationary zinc rods, and a pivoting arm. The free end of the arm forms a pad which rests against a valve seat. The rods and pivoting arm expand or contract as the temperature of the incoming preheated water changes. The zinc rods expand more than the steel rod, flexing the yoke and rotating the pivoting arm. The pad moves towards the valve seat as the temperature of the preheated water rises, and away as the temperature falls, admitting a variable amount of hot water to maintain a nearly constant average process water temperature. 6 figs.

  3. Wastewater heat recovery method and apparatus

    DOEpatents

    Kronberg, J.W.

    1991-01-01

    This invention is comprised of a heat recovery system with a heat exchanger and a mixing valve. A drain trap includes a heat exchanger with an inner coiled tube, baffle plate, wastewater inlet, wastewater outlet, cold water inlet, and preheated water outlet. Wastewater enters the drain trap through the wastewater inlet, is slowed and spread by the baffle plate, and passes downward to the wastewater outlet. Cold water enters the inner tube through the cold water inlet and flows generally upward, taking on heat from the wastewater. This preheated water is fed to the mixing valve, which includes a flexible yoke to which are attached an adjustable steel rod, two stationary zinc rods, and a pivoting arm. The free end of the arm forms a pad which rests against a valve seat. The rods and pivoting arm expand or contract as the temperature of the incoming preheated water changes. The zinc rods expand more than the steel rod, flexing the yoke and rotating the pivoting arm. The pad moves towards the valve seat as the temperature of the preheated water rises, and away as the temperature falls, admitting a variable amount of hot water to maintain a nearly constant average process water temperature.

  4. 2012 Annual Industrial Wastewater Reuse Report for the Idaho National Laboratory Site's Advanced Test Reactor Complex Cold Waste Pond

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mike Lewis

    2013-02-01

    This report describes conditions, as required by the state of Idaho Industrial Wastewater Reuse Permit (#LA 000161 01, Modification B), for the wastewater land application site at the Idaho National Laboratory Site’s Advanced Test Reactor Complex Cold Waste Pond from November 1, 2011 through October 31, 2012. The report contains the following information: Facility and system description Permit required effluent monitoring data and loading rates Groundwater monitoring data Status of compliance activities Noncompliance issues Discussion of the facility’s environmental impacts During the 2012 permit year, approximately 183 million gallons of wastewater were discharged to the Cold Waste Pond. This ismore » well below the maximum annual permit limit of 375 million gallons. As shown by the groundwater sampling data, sulfate and total dissolved solids concentrations are highest near the Cold Waste Pond and decrease rapidly as the distance from the Cold Waste Pond increases. Although concentrations of sulfate and total dissolved solids are elevated near the Cold Waste Pond, both parameters were below the Ground Water Quality Rule Secondary Constituent Standards in the down gradient monitoring wells.« less

  5. 2014 Annual Industrial Wastewater Reuse Report for the Idaho National Laboratory Site’s Advanced Test Reactor Complex Cold Waste Pond

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lewis, Mike

    This report describes conditions, as required by the state of Idaho Industrial Wastewater Reuse Permit (LA 000161 01, Modification B), for the wastewater land application site at the Idaho National Laboratory Site’s Advanced Test Reactor Complex Cold Waste Pond from November 1, 2013–October 31, 2014. The report contains the following information; Facility and system description; Permit required effluent monitoring data and loading rates; Permit required groundwater monitoring data; Status of compliance activities; Noncompliance issues; and Discussion of the facility’s environmental impacts. During the 2014 permit year, approximately 238 million gallons of wastewater were discharged to the Cold Waste Pond. Thismore » is well below the maximum annual permit limit of 375 million gallons. As shown by the groundwater sampling data, sulfate and total dissolved solids concentrations are highest near the Cold Waste Pond and decrease rapidly as the distance from the Cold Waste Pond increases. Although concentrations of sulfate and total dissolved solids are elevated near the Cold Waste Pond, both parameters are below the Ground Water Quality Rule Secondary Constituent Standards in the downgradient monitoring wells.« less

  6. 2013 Annual Industrial Wastewater Reuse Report for the Idaho National Laboratory Site’s Advanced Test Reactor Complex Cold Waste Pond

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mike Lewis

    2014-02-01

    This report describes conditions, as required by the state of Idaho Industrial Wastewater Reuse Permit (#LA 000161 01, Modification B), for the wastewater land application site at the Idaho National Laboratory Site’s Advanced Test Reactor Complex Cold Waste Pond from November 1, 2012–October 31, 2013. The report contains the following information: • Facility and system description • Permit required effluent monitoring data and loading rates • Groundwater monitoring data • Status of compliance activities • Noncompliance issues • Discussion of the facility’s environmental impacts. During the 2013 permit year, approximately 238 million gallons of wastewater was discharged to the Coldmore » Waste Pond. This is well below the maximum annual permit limit of 375 million gallons. As shown by the groundwater sampling data, sulfate and total dissolved solids concentrations are highest near the Cold Waste Pond and decrease rapidly as the distance from the Cold Waste Pond increases. Although concentrations of sulfate and total dissolved solids are elevated near the Cold Waste Pond, both parameters are below the Ground Water Quality Rule Secondary Constituent Standards in the down gradient monitoring wells.« less

  7. Application of cell-based assays for toxicity characterization of complex wastewater matrices: Possible applications in wastewater recycle and reuse.

    PubMed

    Shrivastava, Preeti; Naoghare, Pravin K; Gandhi, Deepa; Devi, S Saravana; Krishnamurthi, Kannan; Bafana, Amit; Kashyap, Sanjay M; Chakrabarti, Tapan

    2017-08-01

    Exposure to pre-concentrated inlet or outlet STP wastewater extracts at different concentrations (0.001% to 1%) induced dose-dependent toxicity in MCF-7 cells, whereas drinking water extracts did not induce cytotoxicity in cells treated. GC-MS analysis revealed the occurrence of xenobiotic compounds (Benzene, Phthalate, etc.) in inlet/outlet wastewater extracts. Cells exposed to inlet/outlet extract showed elevated levels of reactive oxygen species (ROS: inlet: 186.58%, p<0.05, outlet, 147.8%, p<0.01) and loss of mitochondrial membrane potential (Δψm: inlet, 74.91%, p<0.01; outlet, 86.70%, p<0.05) compared to the control. These concentrations induced DNA damage (Tail length: inlet: 34.4%, p<0.05, outlet, 26.7%, p<0.05) in treated cells compared to the control (Tail length: 7.5%). Cell cycle analysis displayed drastic reduction in the G1 phase in treated cells (inlet, G1:45.0%; outlet, G1:58.3%) compared to the control (G1:67.3%). Treated cells showed 45.18% and 28.0% apoptosis compared to the control (1.2%). Drinking water extracts did not show any significant alterations with respect to ROS, Δψm, DNA damage, cell cycle and apoptosis compared to the control. Genes involved in cell cycle and apoptosis were found to be differentially expressed in cells exposed to inlet/outlet extracts. Herein, we propose cell-based toxicity assays to evaluate the efficacies of wastewater treatment and recycling processes. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. MANUAL - CONSTRUCTED WETLANDS TREATMENT OF MUNICIPAL WASTEWATERS

    EPA Science Inventory

    Constructed wetlands are man-made wastewater treatment systems. They usually have one or more cells less than 1 meter deep and are planted with aquatic greenery. Water outlet structures control the flow of wastewater through the system to keep detention times and water levels at ...

  9. Surface wastewater in Samara and their impact on water basins as water supply sources

    NASA Astrophysics Data System (ADS)

    Strelkov, Alexander; Shuvalov, Mikhail; Gridneva, Marina

    2017-10-01

    The paper gives an overview of surface wastewater outlets in Samara through the rainwater sewer system into the Saratov water reservoir and the Samara river. The rainwater sewer system in Samara is designed and executed according to a separate scheme, except for the old part of the city, where surface run-off is dumped into the sewer system through siphoned drain. The rainwater system disposes of surface, drainage, industrial clean-contamined waters, emergency and technology discharges from the city’s heat supply and water supply systems. The effluent discharge is carried out by means of separate wastewater outlets into ravines or directly into the Samara river and the Saratov water reservoir without cleaning. The effluent discharge is carried out through the rainwater sewer system with 17 wastewater outlets into the Saratov water reservoir. In the Samara river, surface runoff drainage and clean-contamined water of industrial enterprises is carried out through 14 wastewater outlets. This study emphasizes the demand to arrange effluent discharge and construction of sewage treatment plants to prevent contamination of water objects by surface run-off from residential areas and industrial territories.

  10. Two Devices for Removing Sludge From Bioreactor Wastewater

    NASA Technical Reports Server (NTRS)

    Archer, Shivaun; Hitchens, G. DUncan; Jabs, Harry; Cross, Jennifer; Pilkinton, Michelle; Taylor, Michael

    2007-01-01

    Two devices a magnetic separator and a special filter denoted a self-regenerating separator (SRS) have been developed for separating sludge from the stream of wastewater from a bioreactor. These devices were originally intended for use in microgravity, but have also been demonstrated to function in normal Earth gravity. The magnetic separator (see Figure 1) includes a thin-walled nonmagnetic, stainless-steel cylindrical drum that rotates within a cylindrical housing. The wastewater enters the separator through a recirculation inlet, and about 80 percent of the wastewater flow leaves through a recirculation outlet. Inside the drum, a magnet holder positions strong permanent magnets stationary and, except near a recirculation outlet, close to the inner drum surface. To enable magnetic separation, magnetite (a ferromagnetic and magnetically soft iron oxide) powder is mixed into the bioreactor wastewater. The magnetite becomes incorporated into the sludge by condensation, onto the powder particles, of microbe flocks that constitute the sludge. As a result, the magnets inside the drum magnetically attract the sludge onto the outer surface of the drum.

  11. Preliminary Cosmogenic Surface Exposure Ages on Laurentide Ice-sheet Retreat and Opening of the Eastern Lake Agassiz Outlets

    NASA Astrophysics Data System (ADS)

    Leydet, D.; Carlson, A. E.; Sinclair, G.; Teller, J. T.; Breckenridge, A. J.; Caffee, M. W.; Barth, A. M.

    2015-12-01

    The chronology for the eastern outlets of glacial Lake Agassiz holds important consequences for the cause of Younger Dryas cold event during the last deglaciation. Eastward routing of Lake Agassiz runoff was originally hypothesized to have triggered the Younger Dryas. However, currently the chronology of the eastern outlets is only constrained by minimum-limiting radiocarbon ages that could suggest the eastern outlets were still ice covered at the start of the Younger Dryas at ~12.9 ka BP, requiring a different forcing of this abrupt climate event. Nevertheless, the oldest radiocarbon ages are still consistent with an ice-free eastern outlet at the start of the Younger Dryas. Here we will present preliminary 10-Be cosmogenic surface exposure ages from the North Lake, Flat Rock Lake, glacial Lake Kaministiquia, and Lake Nipigon outlets located near Thunder Bay, Ontario. These ages will date the timing of the deglaciation of the Laurentide ice sheet in the eastern outlet region of glacial Lake Agassiz. This will provide an important constraint for the hypothesized freshwater forcing of the cause of Younger Dryas cold event.

  12. Radial cold trap

    DOEpatents

    Grundy, Brian R.

    1981-01-01

    The radial cold trap comprises a housing having a plurality of mesh bands disposed therein. The mesh bands comprise concentrically arranged bands of mesh with the mesh specific surface area of each band increasing from the outermost mesh band to the innermost mesh band. An inlet nozzle is attached to the outside section of the housing while an outlet nozzle is attached to the inner portion of the housing so as to be concentrically connected to the innermost mesh band. An inlet baffle having orifices therein may be disposed around the outermost mesh band and within the housing for directing the flow of the fluid from the inlet nozzle to the outermost mesh band in a uniform manner. The flow of fluid passes through each consecutive mesh band and into the outlet nozzle. The circular pattern of the symmetrically arranged mesh packing allows for better utilization of the entire cold trap volume.

  13. Radial cold trap

    DOEpatents

    Grundy, B.R.

    1981-09-29

    The radial cold trap comprises a housing having a plurality of mesh bands disposed therein. The mesh bands comprise concentrically arranged bands of mesh with the mesh specific surface area of each band increasing from the outermost mesh band to the innermost mesh band. An inlet nozzle is attached to the outside section of the housing while an outlet nozzle is attached to the inner portion of the housing so as to be concentrically connected to the innermost mesh band. An inlet baffle having orifices therein may be disposed around the outermost mesh band and within the housing for directing the flow of the fluid from the inlet nozzle to the outermost mesh band in a uniform manner. The flow of fluid passes through each consecutive mesh band and into the outlet nozzle. The circular pattern of the symmetrically arranged mesh packing allows for better utilization of the entire cold trap volume. 2 figs.

  14. 50. OUTLET WORKS: OUTLET STRUCTURE PLAN AND SECTIONS. Sheet ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    50. OUTLET WORKS: OUTLET STRUCTURE - PLAN AND SECTIONS. Sheet C-1, September, 1939. File no. SA 343/50. - Prado Dam, Outlet Works, Santa Ana River near junction of State Highways 71 & 91, Corona, Riverside County, CA

  15. Tofu wastewater treatment by sediment microbial fuel cells

    NASA Astrophysics Data System (ADS)

    Rinaldi, W.; Abubakar; Rahmi, R. F.; Silmina

    2018-03-01

    This research aimed to measure power density generated by sediment microbial fuel cells (SMFCs) by varying anode position and wastewater concentration. Anode position was varied at 2 cm and 4 cm under the surface of sediment, while wastewater concentration varied into 25%, 50%, 75% and 100%. The electrodes employed was stainless steel mesh, while the organic subtrate source was taken from wastewater of soybean washing and boiling process. The sediment was taken from the Lamnyong River around the outlet of tofu industry wastewater. SMFCs was run until the power density was relatively small. The produced electricity represented in power density. The results of this research showed that power density was decreased over time. Generated power density by varying 2 cm and 4 cm position of anode under the sediment surface was not significantly different, while the lowest wastewater concentration, 25%, gave the highest power density.

  16. Periphyton indicate effects of wastewater discharge in the near-coastal zone, Perth (Western Australia)

    NASA Astrophysics Data System (ADS)

    Cosgrove, Jeffrey; Walker, Di; Morrison, Peter; Hillman, Karen

    2004-10-01

    Periphyton communities on artificial substrata were successfully utilised as a biological indicator of the potential eutrophic effects of wastewater discharge into coastal waters off Perth, Western Australia. Biomass and percentage carbonate content measurements of periphyton communities grown in situ indicated that the periphyton primary production (organic weight) was enhanced in the vicinity of the discharge outlets, with a significant negative correlation between distance north of the northern outlet in Whitfords Lagoon and periphyton organic weight (OW) observed in autumn at a depth of 4 m ( r = -0.704, P < 0.001). However, this response was primarily limited to the relatively calm autumn season and substrata at depths of 2 m and 4 m. Thus, in favourable conditions phytoplankton and high relief reef communities are more likely to exhibit a eutrophic influence (in the form of enhanced primary production) of the treated wastewater discharge. Laboratory studies confirmed that treated wastewater, diluted 100-fold to estimate surface concentrations above the wastewater outfalls in the field, stimulates periphyton growth above levels recorded in unpolluted seawater ( F = 12.485; P = 0.0073).

  17. 16. DOWNSTREAM VIEW OF OUTLET STRUCTURE AND OUTLET CHANNEL, FROM ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    16. DOWNSTREAM VIEW OF OUTLET STRUCTURE AND OUTLET CHANNEL, FROM WEST END OF EMBANKMENT. - Prado Dam, Outlet Works, Santa Ana River near junction of State Highways 71 & 91, Corona, Riverside County, CA

  18. 21. AERIAL VIEW OF THE OUTLET STRUCTURE AND OUTLET CHANNEL, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    21. AERIAL VIEW OF THE OUTLET STRUCTURE AND OUTLET CHANNEL, LOOKING UPSTREAM.... Volume XVII, No. 11, December 26, 1939. - Prado Dam, Outlet Works, Santa Ana River near junction of State Highways 71 & 91, Corona, Riverside County, CA

  19. Toxicity identification evaluation of cosmetics industry wastewater.

    PubMed

    de Melo, Elisa Dias; Mounteer, Ann H; Leão, Lucas Henrique de Souza; Bahia, Renata Cibele Barros; Campos, Izabella Maria Ferreira

    2013-01-15

    The cosmetics industry has shown steady growth in many developing countries over the past several years, yet little research exists on toxicity of wastewaters it generates. This study describes a toxicity identification evaluation conducted on wastewater from a small Brazilian hair care products manufacturing plant. Physicochemical and ecotoxicological analyses of three wastewater treatment plant inlet and outlet samples collected over a six month period revealed inefficient operation of the treatment system and thus treated wastewater organic matter, suspended solids and surfactants contents consistently exceeded discharge limits. Treated wastewater also presented high acute toxicity to Daphnia similis and chronic toxicity to Ceriodaphnia dubia and Pseudokirchneriella subcapitata. This toxicity was associated with suspended solids, volatile or sublatable and non-polar to moderately polar organic compounds that could be recovered in filtration and aeration residues. Seven surfactants used in the largest quantities in the production process were highly toxic to P. subcapitata and D. similis. These results indicated that surfactants, important production raw materials, are a probable source of toxicity, although other possible sources, such as fragrances, should not be discarded. Improved treatment plant operational control may reduce toxicity and lower impact of wastewater discharge to receiving waters. Copyright © 2012 Elsevier B.V. All rights reserved.

  20. 2014 Radiological Monitoring Results Associated with the Advanced Test Reactor Complex Cold Waste Pond

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lewis, Mike

    2015-02-01

    This report summarizes radiological monitoring performed of the Idaho National Laboratory Site’s Advanced Test Reactor Complex Cold Waste wastewater prior to discharge into the Cold Waste Pond and of specific groundwater monitoring wells associated with the Industrial Wastewater Reuse Permit (#LA-000161-01, Modification B). All radiological monitoring is performed to fulfill Department of Energy requirements under the Atomic Energy Act.

  1. Macrophyte growth in a pilot-scale constructed wetland for industrial wastewater treatment.

    PubMed

    Hadad, H R; Maine, M A; Bonetto, C A

    2006-06-01

    A pilot-scale wetland was constructed to assess the feasibility of treating the wastewater from a tool industry in Santo Tomé, Santa Fe, Argentina. The wastewater had high conductivity and pH, and contained Cr, Ni and Zn. This paper describes the growth of vegetation in the experimental wetland and the nutrient and metal removal. The wetland was 6 x 3 x 0.4 m. Water discharge was 1000 l d(-1) and residence time was 7d. After the wetland was rendered impermeable, macrophytes from Middle Paraná River floodplain were transplanted. Influent and effluent quality was analyzed every 15 d. TP, Cr, Ni and Zn concentrations in leaves, roots and sediment (inlet and outlet) were measured monthly. Cover and biomass of predominant species were estimated. Also, greenhouse experiments were carried out to measure the effects of conductivity and pH on floating species. The variables measured in the influent were significantly higher than those in the effluent, except for HCO(3)(-) and NH(4)(+). TP and metal concentrations in sediment at the inlet were significantly higher than those at the outlet. Conductivity and pH of the incoming wastewater were toxic for the floating species. Typha domingensis displaced the other species and reached positive relative cover rate and biomass greater than those at the undisturbed natural environment. T. domingensis proved to be highly efficient for the treatment of wastewater. For that reason, it is the advisable species for the treatment of wastewater of high conductivity and pH enriched with metals, characteristic of many industrial processes.

  2. Accelerated carbonation using municipal solid waste incinerator bottom ash and cold-rolling wastewater: Performance evaluation and reaction kinetics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chang, E-E; Pan, Shu-Yuan; Yang, Liuhanzi

    2015-09-15

    Highlights: • Carbonation was performed using CO{sub 2}, wastewater and bottom ash in a slurry reactor. • A maximum capture capacity of 102 g CO{sub 2} per kg BA was achieved at mild conditions. • A maximum carbonation conversion of MSWI-BA was predicted to be 95% by RSM. • The CO{sub 2} emission from Bali incinerator could be expected to reduce by 6480 ton/y. • The process energy consumption per ton CO{sub 2} captured was estimated to be 180 kW h. - Abstract: Accelerated carbonation of alkaline wastes including municipal solid waste incinerator bottom ash (MSWI-BA) and the cold-rolling wastewatermore » (CRW) was investigated for carbon dioxide (CO{sub 2}) fixation under different operating conditions, i.e., reaction time, CO{sub 2} concentration, liquid-to-solid ratio, particle size, and CO{sub 2} flow rate. The MSWI-BA before and after carbonation process were analyzed by the thermogravimetry and differential scanning calorimetry, X-ray diffraction, and scanning electron microscopy equipped with energy dispersive X-ray spectroscopy. The MSWI-BA exhibits a high carbonation conversion of 90.7%, corresponding to a CO{sub 2} fixation capacity of 102 g per kg of ash. Meanwhile, the carbonation kinetics was evaluated by the shrinking core model. In addition, the effect of different operating parameters on carbonation conversion of MSWI-BA was statistically evaluated by response surface methodology (RSM) using experimental data to predict the maximum carbonation conversion. Furthermore, the amount of CO{sub 2} reduction and energy consumption for operating the proposed process in refuse incinerator were estimated. Capsule abstract: CO{sub 2} fixation process by alkaline wastes including bottom ash and cold-rolling wastewater was developed, which should be a viable method due to high conversion.« less

  3. A One Year Study on the Concentrations of Norovirus and Enteric Adenoviruses in Wastewater and A Surface Drinking Water Source in Norway.

    PubMed

    Grøndahl-Rosado, Ricardo C; Yarovitsyna, Ekaterina; Trettenes, Elin; Myrmel, Mette; Robertson, Lucy J

    2014-12-01

    Enteric viruses transmitted via the faecal-oral route occur in high concentrations in wastewater and may contaminate drinking water sources and cause disease. In order to quantify enteric adenovirus and norovirus genotypes I and II (GI and GII) impacting a drinking source in Norway, samples of surface water (52), wastewater inlet (64) and outlet (59) were collected between January 2011 and April 2012. Samples were concentrated in two steps, using an electropositive disc filter and polyethylene glycol precipitation, followed by nucleic acid extraction and analysis by quantitative polymerase chain reaction. Virus was detected in 47/52 (90.4%) of surface water, 59/64 (92%) of wastewater inlet and 55/59 (93%) of wastewater outlet samples. Norovirus GI occurred in the highest concentrations in surface water (2.51e + 04) and adenovirus in wastewater (2.15e + 07). While adenovirus was the most frequently detected in all matrices, norovirus GI was more frequently detected in surface water and norovirus GII in wastewater. This study is the first in Norway to monitor both sewage and a drinking water source in parallel, and confirms the year-round presence of norovirus and adenovirus in a Norwegian drinking water source.

  4. Physicochemical Characteristic of Municipal Wastewater in Tropical Area: Case Study of Surabaya City, Indonesia

    NASA Astrophysics Data System (ADS)

    Wijaya, I. M. W.; Soedjono, E. S.

    2018-03-01

    Municipal wastewater is the main contributor to diverse water pollution problems. In order to prevent the pollution risks, wastewater have to be treated before discharged to the main water. Selection of appropriated treatment process need the characteristic information of wastewater as design consideration. This study aims to analyse the physicochemical characteristic of municipal wastewater from inlet and outlet of ABR unit around Surabaya City. Medokan Semampir and Genteng Candi Rejo has been selected as wastewater sampling point. The samples were analysed in laboratory with parameters, such as pH, TSS, COD, BOD, NH4 +, NO3 -, NO2 -, P, and detergent. The results showed that all parameters in both locations are under the national standard of discharged water quality. In other words, the treated water is securely discharged to the river

  5. Oxygen profile and clogging in vertical flow sand filters for on-site wastewater treatment.

    PubMed

    Petitjean, A; Forquet, N; Boutin, C

    2016-04-01

    13 million people (about 20% of the population) use on-site wastewater treatment in France. Buried vertical sand filters are often built, especially when the soil permeability is not sufficient for septic tank effluent infiltration in undisturbed soil. Clogging is one of the main problems deteriorating the operation of vertical flow filters for wastewater treatment. The extent of clogging is not easily assessed, especially in buried vertical flow sand filters. We suggest examining two possible ways of detecting early clogging: (1) NH4-N/NO3-N outlet concentration ratio, and (2) oxygen measurement within the porous media. Two pilot-scale filters were equipped with probes for oxygen concentration measurements and samples were taken at different depths for pollutant characterization. Influent and effluent grab-samples were taken three times a week. The systems were operated using batch-feeding of septic tank effluent. Qualitative description of oxygen transfer processes under unclogged and clogged conditions is presented. NH4-N outlet concentration appears to be useless for early clogging detection. However, NO3-N outlet concentration and oxygen content allows us to diagnose the early clogging of the system. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. 6. VIEW OF OUTLET GATE WHEEL AND STEM, WITH OUTLET ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    6. VIEW OF OUTLET GATE WHEEL AND STEM, WITH OUTLET CHANNEL IN BACKGROUND, LOOKING SOUTHEAST - High Mountain Dams in Upalco Unit, Island Lake Dam, Ashley National Forest, 4.8 miles North of Miners Gulch Campground, Mountain Home, Duchesne County, UT

  7. 16. VIEW OF HIGHLINE CANAL PIPELINE OUTLET, SHOWING THE OUTLET, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    16. VIEW OF HIGHLINE CANAL PIPELINE OUTLET, SHOWING THE OUTLET, A GROUNDWATER PUMP (LEFT), AND THE SOUTH BRANCH OF THE CANAL (FOREGROUND), August 1989 - Highline Canal & Pumping Station, South side of Salt River between Tempe, Phoenix & Mesa, Tempe, Maricopa County, AZ

  8. Thoracic outlet syndrome part 2: conservative management of thoracic outlet.

    PubMed

    Watson, L A; Pizzari, T; Balster, S

    2010-08-01

    Thoracic outlet syndrome (TOS) is a symptom complex attributed to compression of the nerves and vessels as they exit the thoracic outlet. Classified into several sub-types, conservative management is generally recommended as the first stage treatment in favor of surgical intervention. In cases where postural deviations contribute substantially to compression of the thoracic outlet, the rehabilitation approach outlined in this masterclass will provide the clinician with appropriate management strategies to help decompress the outlet. The main component of the rehabilitation program is the graded restoration of scapula control, movement, and positioning at rest and through movement. Adjunctive strategies include restoration of humeral head control, isolated strengthening of weak shoulder muscles, taping, and other manual therapy techniques. The rehabilitation outlined in this paper also serves as a model for the management of any shoulder condition where scapula dysfunction is a major contributing factor. Copyright 2010 Elsevier Ltd. All rights reserved.

  9. Pilot study of cold-rolling wastewater treatment using single-stage anaerobic fluidized membrane bioreactor.

    PubMed

    Cheng, Hai-Hsuan; Whang, Liang-Ming; Yi, Tse-Fu; Liu, Cheng-Pin; Lin, Tsair-Fuh; Yeh, Mao-Song

    2018-05-09

    A pilot-scale single-stage anaerobic fluidized membrane bioreactor (AFMBR) was firstly used in this study to treat cold-rolling emulsion wastewater from steel industry. It was continuously operated for 302 days with influent COD concentration of 860-1120 mg/L. Under a hydraulic retention time of 1.5 d, the average effluent COD concentration of 72 mg/L achieved corresponding 90% of COD removal. The permeate flux was varied between 1.7 and 2.9 L/m 2 /h during operation which decreased with increased biomass concentration inside AFMBR. The trans-membrane pressure (TMP) was generally around 35-40 kPa, however, it increased up to 60 kPa when volatile suspended solid increased to above 2.5 g/L. Both flux and TMP data reveal the importance of biomass control for AFMBR operation. Results from terminal restriction fragment length polymorphism (T-RFLP) show the genus Methanosaeta was dominant on GAC and it shared dominance with the genera Methanomethylovorans and Methanosarcina in suspended sludge. Copyright © 2018 Elsevier Ltd. All rights reserved.

  10. Design Criteria for Process Wastewater Pretreatment Facilities

    DTIC Science & Technology

    1988-05-01

    chamber where soluble trivalent chromium is formed. The trivalent chromium is then precipitated by raising the pH of the wastewater, usually through...lime addition at the mixing chamber outlet, and removed through claritication. The solubility of trivalent chromium is at a minimum near a solution pH... chromium e compounds are two of the dominant trivalent chromium species. -2 :.: -3- -4- 0 ,. -6 - -6- -7- -8 -a 9 - - .o -I1 - \\ ,.,’. -12 - Cro 2 - CrO3

  11. Alcohol outlets, social disorganization, and robberies: accounting for neighborhood characteristics and alcohol outlet types.

    PubMed

    Snowden, Aleksandra J; Freiburger, Tina L

    2015-05-01

    We estimated spatially lagged regression and spatial regime models to determine if the variation in total, on-premise, and off-premise alcohol outlet(1) density is related to robbery density, while controlling for direct and moderating effects of social disorganization.(2) Results suggest that the relationship between alcohol outlet density and robbery density is sensitive to the measurement of social disorganization levels. Total alcohol outlet density and off-premise alcohol outlet density were significantly associated with robbery density when social disorganization variables were included separately in the models. However, when social disorganization levels were captured as a four item index, only the association between off-premise alcohol outlets and robbery density remained significant. More work is warranted in identifying the role of off-premise alcohol outlets and their characteristics in robbery incidents. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. Compact, Two-Sided Structural Cold Plate Configuration

    NASA Technical Reports Server (NTRS)

    Zaffetti, Mark

    2011-01-01

    In two-sided structural cold plates, typically there is a structural member, such as a honeycomb panel, that provides the structural strength for the cold plates that cool equipment. The cold plates are located on either side of the structural member and thus need to have the cooling fluid supplied to them. One method of accomplishing this is to route the inlet and outlet tubing to both sides of the structural member. Another method might be to supply the inlet to one side and the outlet to the other. With the latter method, an external feature such as a hose, tube, or manifold must be incorporated to pass the fluid from one side of the structural member to the other. Although this is a more compact design than the first option, since it eliminates the need for a dedicated supply and return line to each side of the structural member, it still poses problems, as these external features can be easily damaged and are now new areas for potential fluid leakage. This invention eliminates the need for an external feature and instead incorporates the feature internally to the structural member. This is accomplished by utilizing a threaded insert that not only connects the cold plate to the structural member, but also allows the cooling fluid to flow through it into the structural member, and then to the cold plate on the opposite side. The insert also employs a cap that acts as a cover to seal the open area needed to install the insert. There are multiple options for location of o-ring style seals, as well as the option to use adhesive for redundant sealing. Another option is to weld the cap to the cold plate after its installation, thus making it an integral part of the structural member. This new configuration allows the fluid to pass from one cold plate to the other without any exposed external features.

  13. Data on microbial and physiochemical characteristics of inlet and outlet water from household water treatment devices in Rasht, Iran.

    PubMed

    Naghipour, Dariush; Ashrafi, Seyed Davoud; Mojtahedi, Ali; Vatandoost, Masoud; Hosseinzadeh, Loghman; Roohbakhsh, Esmail

    2018-02-01

    In this research, we measured various parameters related to drinking water quality include turbidity, temperature, pH, EC, TDS, Alkalinity, fecal and total coliform, heterotrophic plate count (HPC), free chlorine, Mn, Ca, Mg, Fe, Na, Cl - , F - , HCO 3 , in the inlet and outlet of household water treatment devices according to the standard methods for the examination of water and wastewater (W.E. Federation and Association and A.P.H., 2005) [1]. Sixty four inlet and outlet water samples were taken from thirty two household water treatment devices from eight different residential blocks in Golsar town of Rasht, Iran. The data obtained from experiments were analyzed using the software Special Package for Social Sciences (SPSS 24) and MS-Excel.

  14. 24 CFR 3280.806 - Receptacle outlets.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ..., 125-volt, either single or duplex. (b) All 120 volt single phase, 15 and 20 ampere receptacle outlets... Receptacle outlets. (b) All 125-volt, single-phase, 15- and 20-ampere receptacle outlets installed outdoors... 24 Housing and Urban Development 5 2014-04-01 2014-04-01 false Receptacle outlets. 3280.806...

  15. Alcohol outlets and clusters of violence

    PubMed Central

    2011-01-01

    Background Alcohol related violence continues to be a major public health problem in the United States. In particular, there is substantial evidence of an association between alcohol outlets and assault. However, because the specific geographic relationships between alcohol outlets and the distribution of violence remains obscured, it is important to identify the spatial linkages that may exist, enhancing public health efforts to curb both violence and morbidity. Methods The present study utilizes police-recorded data on simple and aggravated assaults in Cincinnati, Ohio. Addresses of alcohol outlets for Cincinnati, including all bars, alcohol-serving restaurants, and off-premise liquor and convenience stores were obtained from the Ohio Division of Liquor Control and geocoded for analysis. A combination of proximity analysis, spatial cluster detection approaches and a geographic information system were used to identify clusters of alcohol outlets and the distribution of violence around them. Results A brief review of the empirical work relating to alcohol outlet density and violence is provided, noting that the majority of this literature is cross-sectional and ecological in nature, yielding a somewhat haphazard and aggregate view of how outlet type(s) and neighborhood characteristics like social organization and land use are related to assaultive violence. The results of the statistical analysis for Cincinnati suggest that while alcohol outlets are not problematic per se, assaultive violence has a propensity to cluster around agglomerations of alcohol outlets. This spatial relationship varies by distance and is also related to the characteristics of the alcohol outlet agglomeration. Specifically, spatially dense distributions of outlets appear to be more prone to clusters of assaultive violence when compared to agglomerations with a lower density of outlets. Conclusion With a more thorough understanding of the spatial relationships between alcohol outlets and the

  16. [Spectral Analysis of Dissolved Organic Matter of Tannery Wastewater in the Treatment Process].

    PubMed

    Fan, Chun-hui; Zhang, Ying-chao; Du, Bo; Song, Juan; Huai, Cui-qian; Wang, Jia-hong

    2015-06-01

    Tannery industry is one of the major traditional industries and important wastewater sources in China. The existing research mainly focus on the quality of inlet and outlet water, rather than the purification and transformation behavior of dissolved organic matter (DOM) in the treatment process of tannery wastewater. The UV spectra and fluorescence spectroscopy were used to detect the spectral characteristics of water samples in the treatment process, and it is analyzed that the formation process and the linear relationships between total fluorescence intensity and parameters. The results showed: the UV absorbance of DOM in wastewater increased firstly and then decreased with longer wavelength, and the wave peaks were found around the wavelength of 230 nr. The values of A253 /A203 and SUVA254 increased firstly and then decreased, indicating the complex reaction process related to free substituent and aromatic rings. The fluorescence peaks appeared at the regions of λ(ex/em) = 320-350/440- 460 and λ(ex/em) = 270-300/390-420, referred as visible humic-like and visible fulvic-like fluorescence, respectively. With the treatment process of tannery wastewater, the following fluorescence phenomenon were monitored, such as the blue-shift of humic-like fluorescence peak in the hydrolytic acidification tank, the appearance of tryptophan fluorescence peak in the second biochemical pond (λ(ex/em) = 290/340), the weak fluorescence peak in the fourth biochemical pond (λ(ex/em) = 350/520) and the stabilized fluorescence characteristics in the secondary sedimentation tank and water outlet. The achievements are helpful to investigate the degradation and formation behavior of water components, and significant for the fluorescence variation analysis in the treatment system. The removal rate of total fluorescence intensity of tannery wastewater fit better the removal rate of TOC with coefficient of r 0.835 5. The UV spectra and 3D-EEMs are effective to reveal the purification

  17. Lightweight, Rack-Mountable Composite Cold Plate/Shelves

    NASA Technical Reports Server (NTRS)

    Hurlbert, Kathryn M.; Ruemmele, Warren; Nguyen, Hai D.; Andish, Kambiz; McCalley, Sean

    2004-01-01

    Rack-mountable composite-material structural components that would serve as both shelves and cold plates for removing heat from electronic or other equipment mounted on the shelves have been proposed as lightweight alternatives to all-metal cold plate/shelves now in use. A proposed cold plate/shelf would include a highly thermally conductive face sheet containing oriented graphite fibers bonded to an aluminum honeycomb core, plus an extruded stainless-steel substructure containing optimized flow passages for a cooling fluid, and an inlet and outlet that could be connected to standard manifold sections. To maximize heat-transfer efficiency, the extruded stainless-steel substructure would be connected directly to the face sheet. On the basis of a tentative design, the proposed composite cold plate/shelf would weigh about 38 percent less than does an all-aluminum cold plate in use or planned for use in some spacecraft and possibly aircraft. Although weight is a primary consideration, the tentative design offers the additional benefit of reduction of thickness to half that of the all-aluminum version.

  18. Denitrifying bioreactor clogging potential during wastewater treatment.

    PubMed

    Christianson, Laura E; Lepine, Christine; Sharrer, Kata L; Summerfelt, Steven T

    2016-11-15

    Chemoheterotrophic denitrification technologies using woodchips as a solid carbon source (i.e., woodchip bioreactors) have been widely trialed for treatment of diffuse-source agricultural nitrogen pollution. There is growing interest in the use of this simple, relatively low-cost biological wastewater treatment option in waters with relatively higher total suspended solids (TSS) and chemical oxygen demand (COD) such as aquaculture wastewater. This work: (1) evaluated hydraulic retention time (HRT) impacts on COD/TSS removal, and (2) assessed the potential for woodchip clogging under this wastewater chemistry. Four pilot-scale woodchip denitrification bioreactors operated for 267 d showed excellent TSS removal (>90%) which occurred primarily near the inlet, and that COD removal was maximized at lower HRTs (e.g., 56% removal efficiency and 25 g of COD removed per m 3 of bioreactor per d at a 24 h HRT). However, influent wastewater took progressively longer to move into the woodchips likely due to a combination of (1) woodchip settling, (2) clogging due to removed wastewater solids and/or accumulated bacterial growth, and (3) the pulsed flow system pushing the chips away from the inlet. The bioreactor that received the highest loading rate experienced the most altered hydraulics. Statistically significant increases in woodchip P content over time in woodchip bags placed near the bioreactor outlets (0.03 vs 0.10%P 2 O 5 ) and along the bioreactor floor (0.04 vs. 0.12%P 2 O 5 ) confirmed wastewater solids were being removed and may pose a concern for subsequent nutrient mineralization and release. Nevertheless, the excellent nitrate-nitrogen and TSS removal along with notable COD removal indicated woodchip bioreactors are a viable water treatment technology for these types of wastewaters given they are used downstream of a filtration device. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  19. Evaluation of constructed wetland treatment performance for winery wastewater.

    PubMed

    Grismer, Mark E; Carr, Melanie A; Shepherd, Heather L

    2003-01-01

    Rapid expansion of wineries in rural California during the past three decades has created contamination problems related to winery wastewater treatment and disposal; however, little information is available about performance of on-site treatment systems. Here, the project objective was to determine full-scale, subsurface-flow constructed wetland retention times and treatment performance through assessment of water quality by daily sampling of total dissolved solids, pH, total suspended solids, chemical oxygen demand (COD), tannins, nitrate, ammonium, total Kjeldahl nitrogen, phosphate, sulfate, and sulfide across operating systems for winery wastewater treatment. Measurements were conducted during both the fall crush season of heavy loading and the spring following bottling and racking operations at the winery. Simple decay model coefficients for these constituents as well as COD and tannin removal efficiencies from winery wastewater in bench-scale reactors are also determined. The bench-scale study used upward-flow, inoculated attached-growth (pea-gravel substrate) reactors fed synthetic winery wastewater. Inlet and outlet tracer studies for determination of actual retention times were essential to analyses of treatment performance from an operational subsurface-flow constructed wetland that had been overloaded due to failure to install a pretreatment system for suspended solids removal. Less intensive sampling conducted at a smaller operational winery wastewater constructed wetland that had used pretreatment suspended solids removal and aeration indicated that the constructed wetlands were capable of complete organic load removal from the winery wastewater.

  20. Natural treatment system models for wastewater management: a study from Hyderabad, India.

    PubMed

    Sonkamble, Sahebrao; Wajihuddin, Md; Jampani, Mahesh; Sarah, S; Somvanshi, V K; Ahmed, Shakeel; Amerasinghe, Priyanie; Boisson, Alexandre

    2018-01-01

    Wastewater generated on a global scale has become a significant source of water resources which necessitates appropriate management strategies. However, the complexities associated with wastewater are lack of economically viable treatment systems, especially in low- and middle-income countries. While many types of treatment systems are needed to serve the various local issues, we propose natural treatment systems (NTS) such as natural wetlands that are eco-friendly, cost-effective, and can be jointly driven by public bodies and communities. In order for it to be part of wastewater management, this study explores the NTS potential for removal of pollutants, cost-effectiveness, and reuse options for the 1.20 million m 3 /day of wastewater generated in Hyderabad, India. The pilot study includes hydro-geophysical characterization of natural wetland to determine pollutant removal efficiency and its effective utilization for treated wastewater in the peri-urban habitat. The results show the removal of organic content (76-78%), nutrients (77-97%), and microbes (99.5-99.9%) from the wetland-treated wastewater and its suitability for agriculture applications. Furthermore, the wetland efficiency integrated with engineered interventions led to the development of NTS models with different application scenarios: (i) constructed wetlands, (ii) minimized community wetlands, and (iii) single outlet system, suitable for urban, peri-urban and rural areas, respectively.

  1. Potential of combining mechanical and physicochemical municipal wastewater pre-treatment with direct membrane filtration.

    PubMed

    Hey, Tobias; Väänänen, Janne; Heinen, Nicolas; la Cour Jansen, Jes; Jönsson, Karin

    2017-01-01

    At a full-scale wastewater treatment plant, raw municipal wastewater from the sand trap outlet was mechanically and physicochemically pre-treated before microfiltration (MF) in a large pilot-scale study. MF was performed using a low transmembrane pressure (0.03 bar) without backflushing for up to 159 h (∼6.6 d). Pre-filtration ensured stable MF operation compared with the direct application of raw wastewater on the membrane. The combination of physicochemical pre-treatment, such as coagulation, flocculation, and microsieving, with MF meets the European and Swedish discharge limits for small- and medium-sized wastewater treatment plants (WWTPs). The specific electricity footprint was 0.3-0.4 kWh·m -3 , which is an improvement compared to the median footprint of 0.75 kWh·m -3 found in 105 traditional Swedish WWTPs with sizes of 1500-10,000 person equivalents. Furthermore, the biological treatment step can be omitted, and the risk of releasing greenhouse gases was eliminated. The investigated wastewater treatment process required less space than conventional wastewater treatment processes, and more carbon was made available for biogas production.

  2. Use of secondary-treated wastewater for the production of Muriellopsis sp.

    PubMed

    Gómez, C; Escudero, R; Morales, M M; Figueroa, F L; Fernández-Sevilla, J M; Acién, F G

    2013-03-01

    In this paper, the use of secondary-treated wastewater as the culture medium for the production of Muriellopsis sp. microalgal biomass is analyzed. Using this wastewater, a maximum biomass productivity of 0.5 g l(-1) day(-1) was measured, it being only 38 % lower than that achieved using the standard culture medium. Due to the low nitrogen content of secondary-treated wastewater, cultures produced in a medium containing a high percentage of it become nitrate-limited, thus the quantum yield reduces by up to 0.38 g E(-1)--this compares to 0.67 g E(-1) when using a standard culture medium. On the other hand, nitrate limitation enhances the accumulation of lipids and carbohydrates, with values measured at 33 and 66 % dry weight, respectively. It was also demonstrated that secondary-treated wastewater does not have any toxic effect on the growth of Muriellopsis sp. in spite of nitrogen being in the form of ammonium rather than in nitrate. Moreover, the secondary-treated wastewater was depurated when used to produce Muriellopsis sp., with the outlet biological oxygen demand and chemical oxygen demand being lower than at the inlet; the nitrate and phosphate concentrations were zero. Therefore, Muriellopsis sp. production using secondary-treated wastewater allows a reduction in the process cost by decreasing freshwater and fertilizer use, as well as by depurating the water, thus greatly enhancing process sustainability.

  3. Study on fermentation kinetics and extraction process of rhamnolipid production by papermaking wastewater

    NASA Astrophysics Data System (ADS)

    Yu, Keer

    2018-01-01

    Paper mill wastewater (PMW) is the outlet water generated during pulp and papermaking process in the paper industry. Fermentation by wastewater can lower the cost of production as well as alleviate the pressure of wastewater treatment. Rhamnolipids find broad placations as natural surfactants. This paper studied the rhamnolipids fermentation by employing Pseudomonas aeruginosa isolated by the laboratory, and determined to use wastewater which filtered by medium speed filter paper and strain Z2, the culture conditions were optimized, based on the flask shaking fermentation. On the basis of 5L tank fermentation, batch fermentation was carried out, the yield of fermentation reached 7.067g/L and the fermentation kinetics model of cell growth, product formation and substrate consumption was established by using origin software, and the fermentation process could be simulated well. And studied on the extraction process of rhamnolipids, through fermentation dynamic equation analysis can predict the in fill material yield can be further improved. Research on the extraction process of rhamnolipid simplifies the operation of extraction, and lays the foundation for the industrial extraction.

  4. Aerobic granulation in a sequencing batch reactor (SBR) for industrial wastewater treatment.

    PubMed

    Inizan, M; Freval, A; Cigana, J; Meinhold, J

    2005-01-01

    Aerobic granulation seems to be an a attractive process for COD removal from industrial wastewater, characterised by a high content of soluble organic compounds. In order to evaluate the practical aspects of the process, comparative experimental tests are performed on synthetic and on industrial wastewater, originating from pharmaceutical industry. Two pilot plants are operated as sequencing batch bubble columns. Focus was put on the feasibility of the process for high COD removal and on its operational procedure. For both wastewaters, a rapid formation of aerobic granules is observed along with a high COD removal rate. Granule characteristics are quite similar with respect to the two types of wastewater. It seems that filamentous bacteria are part of the granule structure and that phosphorus precipitation can play an important role in granule formation. For both wastewaters similar removal performances for dissolved biodegradable COD are observed (> 95%). However, a relatively high concentration of suspended solids in the outlet deteriorates the performance with regard to total COD removal. Biomass detachment seems to play a non-negligible role in the current set-up. After a stable operational phase the variation of the pharmaceutical wastewater caused a destabilisation and loss of the granules, despite the control for balanced nutrient supply. The first results with real industrial wastewater demonstrate the feasibility of this innovative process. However, special attention has to be paid to the critical aspects such as granule stability as well as the economic competitiveness, which both will need further investigation and evaluation.

  5. Audit of tobacco retail outlets in Hangzhou, China.

    PubMed

    Gong, Ting; Lv, Jun; Liu, Qingmin; Ren, Yanjun; Li, Liming; Kawachi, Ichiro

    2013-07-01

    To determine the prevalence of tobacco advertisements and warning messages at points of sale as well as to examine the density of tobacco retail outlets in neighbourhoods and around schools in Hangzhou, China. Tobacco retail outlets (n=1639) in all food and tobacco specialty stores were observed objectively by trained students. Tobacco advertisements and warning messages were assessed with an audit, and stores' addresses were recorded with Global Positioning System coordinates. The distances (1) between all pairs of tobacco retail outlets (2) between each tobacco retail outlet and 15 middle schools were calculated to assess the density of tobacco retail outlets in neighbourhoods and around schools. Among the 1639 tobacco retail outlets, <1% had 'no sales to minors' signs, 1.5% had tobacco warning messages, 28% had signs indicating tobacco sale and 12.4% had tobacco advertisements. For 48.7% of tobacco retail outlets, the nearest distances to other tobacco retail outlets were <50 m. For 80% of schools, there was at least one tobacco retail outlets within a 100 m radius. Tobacco advertisement in retail outlets is prevalent and the density of tobacco retail outlets is high in Hangzhou, China. Signs indicating 'no sales to minors' and tobacco warning signs are almost non-existent. These findings point to an urgent need for the enforcement of regulations on display of 'no sales to minors' and a new density standard for tobacco retail outlets based on protecting the public's health.

  6. Field validation of secondary data sources for enumerating retail tobacco outlets in a state without tobacco outlet licensing.

    PubMed

    D'Angelo, Heather; Fleischhacker, Sheila; Rose, Shyanika W; Ribisl, Kurt M

    2014-07-01

    Identifying tobacco retail outlets for U.S. FDA compliance checks or calculating tobacco outlet density is difficult in the 13 States without tobacco retail licensing or where licensing lists are unavailable for research. This study uses primary data collection to identify tobacco outlets in three counties in a non-licensing state and validate two commercial secondary data sources. We calculated sensitivity and positive predictive values (PPV) to examine the evidence of validity for two secondary data sources, and conducted a geospatial analysis to determine correct allocation to census tract. ReferenceUSA had almost perfect sensitivity (0.82) while Dun & Bradstreet (D&B) had substantial sensitivity (0.69) for identifying tobacco outlets; combined, sensitivity improved to 0.89. D&B identified fewer "false positives" with a PPV of 0.82 compared to 0.71 for ReferenceUSA. More than 90% of the outlets identified by ReferenceUSA were geocoded to the correct census tract. Combining two commercial data sources resulted in enumeration of nearly 90% of tobacco outlets in a three county area. Commercial databases appear to provide a reasonably accurate way to identify tobacco outlets for enforcement operations and density estimation. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. Race, Ethnicity, and Exposure to Alcohol Outlets.

    PubMed

    Morrison, Christopher; Gruenewald, Paul J; Ponicki, William R

    2016-01-01

    Prior studies suggest that Black and Hispanic minority populations are exposed to greater concentrations of alcohol outlets, potentially contributing to health disparities between these populations and the White majority. We tested the alternative hypothesis that urban economic systems cause outlets to concentrate in low-income areas and, controlling for these effects, lower demand among minority populations leads to fewer outlets. Market potential for alcohol sales, a surrogate for demand, was estimated from survey and census data across census block groups for 50 California cities. Hierarchical Bayesian conditional autoregressive Poisson models then estimated relationships between observed geographic distributions of outlets and the market potential for alcohol, income, population size, and racial and ethnic composition. Market potentials were significantly smaller among lower income Black, Hispanic, and Asian populations. Block groups with greater market potential and lower income had greater concentrations of outlets. When we controlled for these effects, the racial and ethnic group composition of block groups was mostly unrelated to outlet concentrations. Health disparities related to exposure to alcohol outlets are primarily driven by distributions of income and population density across neighborhoods.

  8. Treatment of Arctic wastewater by chemical coagulation, UV and peracetic acid disinfection.

    PubMed

    Chhetri, Ravi Kumar; Klupsch, Ewa; Andersen, Henrik Rasmus; Jensen, Pernille Erland

    2017-02-16

    Conventional wastewater treatment is challenging in the Arctic region due to the cold climate and scattered population. Thus, no wastewater treatment plant exists in Greenland, and raw wastewater is discharged directly to nearby waterbodies without treatment. We investigated the efficiency of physicochemical wastewater treatment, in Kangerlussuaq, Greenland. Raw wastewater from Kangerlussuaq was treated by chemical coagulation and UV disinfection. By applying 7.5 mg Al/L polyaluminium chloride (PAX XL100), 73% of turbidity and 28% phosphate was removed from raw wastewater. E. coli and Enterococcus were removed by 4 and 2.5 log, respectively, when UV irradiation of 0.70 kWh/m 3 was applied to coagulated wastewater. Furthermore, coagulated raw wastewater in Denmark, which has a chemical quality similar to Greenlandic wastewater, was disinfected by peracetic acid or UV irradiation. Removal of heterotrophic bacteria by applying 6 and 12 mg/L peracetic acid was 2.8 and 3.1 log, respectively. Similarly, removal of heterotrophic bacteria by applying 0.21 and 2.10 kWh/m 3 for UV irradiation was 2.1 and greater than 4 log, respectively. Physicochemical treatment of raw wastewater followed by UV irradiation and/or peracetic acid disinfection showed the potential for treatment of arctic wastewater.

  9. Complex Greenland outlet glacier flow captured

    PubMed Central

    Aschwanden, Andy; Fahnestock, Mark A.; Truffer, Martin

    2016-01-01

    The Greenland Ice Sheet is losing mass at an accelerating rate due to increased surface melt and flow acceleration in outlet glaciers. Quantifying future dynamic contributions to sea level requires accurate portrayal of outlet glaciers in ice sheet simulations, but to date poor knowledge of subglacial topography and limited model resolution have prevented reproduction of complex spatial patterns of outlet flow. Here we combine a high-resolution ice-sheet model coupled to uniformly applied models of subglacial hydrology and basal sliding, and a new subglacial topography data set to simulate the flow of the Greenland Ice Sheet. Flow patterns of many outlet glaciers are well captured, illustrating fundamental commonalities in outlet glacier flow and highlighting the importance of efforts to map subglacial topography. Success in reproducing present day flow patterns shows the potential for prognostic modelling of ice sheets without the need for spatially varying parameters with uncertain time evolution. PMID:26830316

  10. Community Alcohol Outlet Density and Underage Drinking

    PubMed Central

    Chen, Meng-Jinn; Grube, Joel W.; Gruenewald, Paul J.

    2009-01-01

    Aim This study examined how community alcohol outlet density may be associated with drinking among youths. Methods Longitudinal data were collected from 1091 adolescents (aged 14–16 at baseline) recruited from 50 zip codes in California with varying levels of alcohol outlet density and median household income. Hierarchical linear models were used to examine the associations between zip code alcohol outlet density and frequency rates of general alcohol use and excessive drinking, taking into account zip code median household income and individual-level variables (age, gender, race/ethnicity, personal income, mobility, and perceived drinking by parents and peers). Findings When all other factors were controlled, higher initial levels of drinking and excessive drinking were observed among youths residing in zip codes with higher alcohol outlet densities. Growth in drinking and excessive drinking was on average more rapid in zip codes with lower alcohol outlet densities. The relation of zip code alcohol outlet density with drinking appeared to be mitigated by having friends with access to a car. Conclusion Alcohol outlet density may play a significant role in initiation of underage drinking during early teen ages, especially when youths have limited mobility. Youth who reside in areas with low alcohol outlet density may overcome geographic constraints through social networks that increase their mobility and the ability to seek alcohol and drinking opportunities beyond the local community. PMID:20078485

  11. Race, Ethnicity, and Exposure to Alcohol Outlets

    PubMed Central

    Morrison, Christopher; Gruenewald, Paul J.; Ponicki, William R.

    2016-01-01

    Objective: Prior studies suggest that Black and Hispanic minority populations are exposed to greater concentrations of alcohol outlets, potentially contributing to health disparities between these populations and the White majority. We tested the alternative hypothesis that urban economic systems cause outlets to concentrate in low-income areas and, controlling for these effects, lower demand among minority populations leads to fewer outlets. Method: Market potential for alcohol sales, a surrogate for demand, was estimated from survey and census data across census block groups for 50 California cities. Hierarchical Bayesian conditional autoregressive Poisson models then estimated relationships between observed geographic distributions of outlets and the market potential for alcohol, income, population size, and racial and ethnic composition. Results: Market potentials were significantly smaller among lower income Black, Hispanic, and Asian populations. Block groups with greater market potential and lower income had greater concentrations of outlets. When we controlled for these effects, the racial and ethnic group composition of block groups was mostly unrelated to outlet concentrations. Conclusions: Health disparities related to exposure to alcohol outlets are primarily driven by distributions of income and population density across neighborhoods. PMID:26751356

  12. 46 CFR 193.15-25 - Discharge outlets.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Discharge outlets. 193.15-25 Section 193.15-25 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 193.15-25 Discharge outlets. (a) Discharge outlets...

  13. 46 CFR 76.15-25 - Discharge outlets.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 3 2010-10-01 2010-10-01 false Discharge outlets. 76.15-25 Section 76.15-25 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 76.15-25 Discharge outlets. (a) Discharge outlets shall...

  14. 46 CFR 76.15-25 - Discharge outlets.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 3 2013-10-01 2013-10-01 false Discharge outlets. 76.15-25 Section 76.15-25 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 76.15-25 Discharge outlets. (a) Discharge outlets shall...

  15. 46 CFR 76.15-25 - Discharge outlets.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 3 2011-10-01 2011-10-01 false Discharge outlets. 76.15-25 Section 76.15-25 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 76.15-25 Discharge outlets. (a) Discharge outlets shall...

  16. 46 CFR 76.15-25 - Discharge outlets.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 3 2012-10-01 2012-10-01 false Discharge outlets. 76.15-25 Section 76.15-25 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 76.15-25 Discharge outlets. (a) Discharge outlets shall...

  17. 46 CFR 76.15-25 - Discharge outlets.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 3 2014-10-01 2014-10-01 false Discharge outlets. 76.15-25 Section 76.15-25 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 76.15-25 Discharge outlets. (a) Discharge outlets shall...

  18. 46 CFR 193.15-25 - Discharge outlets.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Discharge outlets. 193.15-25 Section 193.15-25 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 193.15-25 Discharge outlets. (a) Discharge outlets...

  19. 46 CFR 76.17-20 - Discharge outlets.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 3 2011-10-01 2011-10-01 false Discharge outlets. 76.17-20 Section 76.17-20 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Foam Extinguishing Systems, Details § 76.17-20 Discharge outlets. (a) Discharge outlets shall be of an...

  20. 46 CFR 95.17-20 - Discharge outlets.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Discharge outlets. 95.17-20 Section 95.17-20 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS FIRE PROTECTION EQUIPMENT Foam Extinguishing Systems, Details § 95.17-20 Discharge outlets. (a) Discharge outlets shall be...

  1. 46 CFR 95.17-20 - Discharge outlets.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Discharge outlets. 95.17-20 Section 95.17-20 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS FIRE PROTECTION EQUIPMENT Foam Extinguishing Systems, Details § 95.17-20 Discharge outlets. (a) Discharge outlets shall be...

  2. 46 CFR 76.17-20 - Discharge outlets.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 3 2010-10-01 2010-10-01 false Discharge outlets. 76.17-20 Section 76.17-20 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Foam Extinguishing Systems, Details § 76.17-20 Discharge outlets. (a) Discharge outlets shall be of an...

  3. 46 CFR 95.15-25 - Discharge outlets.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Discharge outlets. 95.15-25 Section 95.15-25 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 95.15-25 Discharge outlets. (a) Discharge outlets...

  4. 46 CFR 95.15-25 - Discharge outlets.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Discharge outlets. 95.15-25 Section 95.15-25 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 95.15-25 Discharge outlets. (a) Discharge outlets...

  5. 46 CFR 95.15-25 - Discharge outlets.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Discharge outlets. 95.15-25 Section 95.15-25 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 95.15-25 Discharge outlets. (a) Discharge outlets...

  6. Off-premise alcohol outlet characteristics and violence.

    PubMed

    Snowden, Aleksandra J; Pridemore, William Alex

    2014-07-01

    There is considerable evidence of an association between alcohol outlet density and violence. Although prior research reveals the importance of specific characteristics of bars on this association and that the relationship between bar density and violence may be moderated by these characteristics, there are few similar studies of the characteristics of off-premise outlets (e.g., liquor and convenience stores). We examined whether immediate environment, business practice, staff, and patron characteristics of off-premise alcohol outlets are associated with simple and aggravated assault density. Cross-sectional design using aggregate data from 65 census block groups in a non-metropolitan college town, systematic social observation, and spatial modeling techniques. We found limited effects of immediate environment, business practice, staff, and patron characteristics on simple assault density and no effect on aggravated assault density. Only two out of 17 characteristics were associated with simple assault density (i.e., nearby library and male patrons). This is the first study to examine the association between several off-premise alcohol outlet characteristics and assault. Our findings suggest that where the off-premise outlets are located, how well the immediate environment is maintained, what types of beverages the outlets sell, who visits them, and who works there matter little in their association with violence. This suggests the importance of outlet density itself as a primary driver of any association with violence. Public policies aimed at reducing alcohol outlet density or clustering may be useful for reducing violence.

  7. Socioeconomic determinants of exposure to alcohol outlets.

    PubMed

    Morrison, Christopher; Gruenewald, Paul J; Ponicki, William R

    2015-05-01

    Alcohol outlets tend to be located in lower income areas, exposing lower income populations to excess risks associated with alcohol sales through these establishments. The objective of this study was to test two hypotheses about the etiology of these differential exposures based on theories of the economic geography of retail markets: (a) outlets will locate within or near areas of high alcohol demand, and (b) outlets will be excluded from areas with high land and structure rents. Data from the 2010 National Drug Strategy Household Survey were used to develop a surrogate for alcohol demand (i.e., market potential) at two census geographies for the city of Melbourne, Australia. Bayesian conditional autoregressive Poisson models estimated multilevel spatial relationships between counts of bars, restaurants, and off-premise outlets and market potential, income, and zoning ordinances (Level 1: n = 8,914). Market potentials were greatest in areas with larger older age, male, English-speaking, high-income populations. Independent of zoning characteristics, greater numbers of outlets appeared in areas with greater market potentials and the immediately surrounding areas. Greater income excluded outlets in local and surrounding areas. These findings are consistent with the hypothesis that alcohol outlets are located in areas with high demand and are excluded from high-income areas. These processes appear to take place at relatively small geographic scales, encourage the concentration of outlets in specific low-income areas, and represent a very general economic process likely to take place in communities throughout the world.

  8. Outlet Glacier-Ice Shelf-Ocean Interactions: Is the Tail Wagging the Dog?

    NASA Astrophysics Data System (ADS)

    Parizek, B. R.; Walker, R. T.; Rinehart, S. K.

    2009-12-01

    While the massive interior regions of the Antarctic and Greenland Ice Sheets are presently ``resting quietly", the lower elevations of many outlet glaciers are experiencing dramatic adjustments due to changes in ice dynamics and/or surface mass balance. Oceanic and/or atmospheric forcing in these marginal regions often leads to mass deficits for entire outlet basins. Therefore, coupling the wagging tail of ice-ocean interactions with the vast ice-sheet reservoirs is imperative for accurate assessments of future sea-level rise. To study ice-ocean dynamic processes, we couple an ocean-plume model that simulates ice-shelf basal melting rates based on temperature and salinity profiles combined with plume dynamics associated with the geometry of the ice-shelf cavity (following Jenkins, 1991 and Holland and Jenkins, 1999) with a two-dimensional, isothermal model of outlet glacier-ice shelf flow (as used in Alley et al., 2007; Walker et al., 2008; Parizek et al., in review). Depending on the assigned temperature and salinity profiles, the ocean model can simulate both water-mass end-members: either cold High Salinity Shelf Water (HSSW) or relatively warm Circumpolar Deep Water (CDW), as well as between-member conditions. Notably, the coupled system exhibits sensitivity to the initial conditions. In particular, melting concentrated near the grounding line has the greatest effect in forcing grounding-line retreat. Retreat is further enhanced by a positive feedback between the ocean and ice, as the focused melt near the grounding line leads to an increase in the local slope of the basal ice, thereby enhancing buoyancy-driven plume flow and subsequent melt rates.

  9. PBF Cooling Tower under construction. Cold water basin is five ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    PBF Cooling Tower under construction. Cold water basin is five feet deep. Foundation and basin walls are reinforced concrete. Camera facing west. Pipe openings through wall in front are outlets for return flow of cool water to reactor building. Photographer: John Capek. Date: September 4, 1968. INEEL negative no. 68-3473 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID

  10. Socioeconomic Determinants of Exposure to Alcohol Outlets

    PubMed Central

    Morrison, Christopher; Gruenewald, Paul J.; Ponicki, William R.

    2015-01-01

    Objective: Alcohol outlets tend to be located in lower income areas, exposing lower income populations to excess risks associated with alcohol sales through these establishments. The objective of this study was to test two hypotheses about the etiology of these differential exposures based on theories of the economic geography of retail markets: (a) outlets will locate within or near areas of high alcohol demand, and (b) outlets will be excluded from areas with high land and structure rents. Method: Data from the 2010 National Drug Strategy Household Survey were used to develop a surrogate for alcohol demand (i.e., market potential) at two census geographies for the city of Melbourne, Australia. Bayesian conditional autoregressive Poisson models estimated multilevel spatial relationships between counts of bars, restaurants, and off-premise outlets and market potential, income, and zoning ordinances (Level 1: n = 8,914). Results: Market potentials were greatest in areas with larger older age, male, English-speaking, high-income populations. Independent of zoning characteristics, greater numbers of outlets appeared in areas with greater market potentials and the immediately surrounding areas. Greater income excluded outlets in local and surrounding areas. Conclusions: These findings are consistent with the hypothesis that alcohol outlets are located in areas with high demand and are excluded from high-income areas. These processes appear to take place at relatively small geographic scales, encourage the concentration of outlets in specific low-income areas, and represent a very general economic process likely to take place in communities throughout the world. PMID:25978830

  11. Outlet diffusers to increase culvert capacity.

    DOT National Transportation Integrated Search

    2016-06-01

    Aging infrastructure and changing weather patterns present the need to increase the capacity of existing highway culverts. This research approaches this challenge through the use of diffuser outlet systems to increase pipe capacity and reduce outlet ...

  12. 49 CFR 179.220-18 - Bottom outlets.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Specifications for Non-Pressure Tank Car Tanks (Classes DOT-111AW and 115AW) § 179.220-18 Bottom outlets. (a) The... equivalent, except that bottom outlet closure plugs may be attached by 1/4-inch chain. When the bottom outlet... valve body may be steam jacketed, in which case the breakage groove or its equivalent must be below the...

  13. Evaluation of Shiraz wastewater treatment plant effluent quality for agricultural irrigation by Canadian Water Quality Index (CWQI)

    PubMed Central

    2013-01-01

    Background Using treated wastewater in agriculture irrigation could be a realistic solution for the shortage of fresh water in Iran, however, it is associated with environmental and health threats; therefore, effluent quality assessment is quite necessary before use. The present study aimed to evaluate the physicochemical and microbial quality of Shiraz wastewater treatment plant effluent for being used in agricultural irrigation. In this study, 20 physicochemical and 3 microbial parameters were measured during warm (April to September) and cold months (October to march). Using the measured parameters and the Canadian Water Quality Index, the quality of the effluent was determined in both warm and cold seasons and in all the seasons together. Results The calculated index for the physicochemical parameters in the effluent was equal (87) in warm and cold months and it was obtained as 85 for the seasons all together. When the microbial parameters were used in order to calculate the index, it declined to 67 in warm and cold seasons and 64 in all the seasons together. Also, it was found that three physicochemical parameters (TDS, EC, and NO3) and three microbial parameters (Fecal coliform, Helminthes egg, and Total coliform) had the most contribution to the reduction of the index value. Conclusions The results showed that the physicochemical quality of Shiraz Wastewater Treatment Plant Effluent was good for irrigation in the warm, cold, and total of the two kinds of seasons. However, by applying the microbial parameter, the index value declined dramatically and the quality of the effluent was marginal. PMID:23566673

  14. Accumulation of contaminants in fish from wastewater treatment wetlands

    USGS Publications Warehouse

    Barber, L.B.; Keefe, S.H.; Antweiler, Ronald C.; Taylor, Howard E.; Wass, R.D.

    2006-01-01

    Increasing demands on water resources in arid environments make reclamation and reuse of municipal wastewater an important component of the water budget. Treatment wetlands can be an integral part of the water-reuse cycle providing both water-quality enhancement and habitat functions. When used for habitat, the bioaccumulation potential of contaminants in the wastewater is a critical consideration. Water and fish samples collected from the Tres Rios Demonstration Constructed Wetlands near Phoenix, Arizona, which uses secondary-treated wastewater to maintain an aquatic ecosystem in a desert environment, were analyzed for hydrophobic organic compounds (HOC) and trace elements. Semipermeable membrane devices (SPMD) were deployed to investigate uptake of HOC. The wetlands effectively removed HOC, and concentrations of herbicides, pesticides, and organic wastewater contaminants decreased 40-99% between inlet and outlet. Analysis of Tilapia mossambica and Gambusia affinis indicated accumulation of HOC, including p,p???-DDE and trans-nonachlor. The SPMD accumulated the HOC detected in the fish tissue as well as additional compounds. Trace-element concentrations in whole-fish tissue were highly variable, but were similar between the two species. Concentrations of HOC and trace elements varied in different fish tissue compartments, and concentrations in Tilapia liver tissue were greater than those in the whole organism or filet tissue. Bioconcentration factors for the trace elements ranged from 5 to 58 000 and for the HOC ranged from 530 to 150 000. ?? 2006 American Chemical Society.

  15. Double-outlet right ventricle revisited.

    PubMed

    Ebadi, Ameneh; Spicer, Diane E; Backer, Carl L; Fricker, F Jay; Anderson, Robert H

    2017-08-01

    Double-outlet right ventricle is a form of ventriculoarterial connection. The definition formulated by the International Society for Nomenclature of Paediatric and Congenital Heart Disease is based on hearts with both arterial trunks supported in their greater part by a morphologically right ventricle. Bilateral infundibula and ventricular septal defects are highly debated criteria. This study examines the anatomic controversies surrounding double-outlet right ventricle. We show that hearts with double-outlet right ventricle can have atrioventricular-to-arterial valvular continuity. We emphasize the difference between the interventricular communication and the zone of deficient ventricular septation. The hearts examined were from the University of Florida in Gainesville; Johns Hopkins All Children's Hospital, St Petersburg, Fla; and Lurie Children's Hospital, Chicago, Ill. Each specimen had at least 75% of both arterial roots supported by the morphologically right ventricle, with a total of 100 hearts examined. The morphologic method was used to assess anatomic features, including arterial-atrioventricular valvular continuity, subarterial infundibular musculature, and the location of the hole between the ventricles. Most hearts had fibrous continuity between one of the arterial valves and an atrioventricular valve, with bilateral infundibula in 23%, and intact ventricular septum in 5%. Bilateral infundibula are not a defining feature of double-outlet right ventricle, representing only 23% of the specimens in our sample. The interventricular communication can have a posteroinferior muscular rim or extend to become perimembranous (58%). Double-outlet right ventricle can exist with an intact ventricular septum. Copyright © 2017 The American Association for Thoracic Surgery. All rights reserved.

  16. Intelligent electrical outlet for collective load control

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lentine, Anthony L.; Ford, Justin R.; Spires, Shannon V.

    Various technologies described herein pertain to an electrical outlet that autonomously manages loads in a microgrid. The electrical outlet can provide autonomous load control in response to variations in electrical power generation supply in the microgrid. The electrical outlet includes a receptacle, a sensor operably coupled to the receptacle, and an actuator configured to selectively actuate the receptacle. The sensor measures electrical parameters at the receptacle. Further, a processor autonomously controls the actuator based at least in part on the electrical parameters measured at the receptacle, electrical parameters from one or more disparate electrical outlets in the microgrid, and amore » supply of generated electric power in the microgrid at a given time.« less

  17. Characterization of a cold-active bacterium isolated from the South Pole “Ice Tunnel”

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Madigan, Michael T.; Kempher, Megan L.; Bender, Kelly S.

    Abstract Extremely cold microbial habitats on Earth (those below -30 °C) are rare and have not been surveyed for microbes as extensively as environments in the 0 to -20 °C range. Using cryoprotected growth media incubated at -5 °C, we enriched a cold-active Pseudomonas species from -50 °C ice collected from a utility tunnel for wastewater pipes under Amundsen–Scott South Pole Station, Antarctica. The isolate, strain UC-1, is related to other cold-active Pseudomonas species, most notably P. psychrophila, and grew at -5 °C to +34–37 °C; growth of UC-1 at +3 °C was significantly faster than at +34 °C. Strainmore » UC-1 synthesized a surface exopolymer and high levels of unsaturated fatty acids under cold growth conditions. A 16S rRNA gene diversity screen of the ice sample that yielded strain UC-1 revealed over 1200 operational taxonomic units (OTUs) distributed across eight major classes of Bacteria. Many of the OTUs were Clostridia and Bacteriodia and some of these were probably of wastewater origin. However, a significant fraction of the OTUs were Proteobacteria and Actinobacteria of likely environmental origin. Our results shed light on the lower temperature limits to life and the possible existence of functional microbial communities in ultra-cold environments.« less

  18. Antivortex Device for Multi-Outlet Liquid Reservoir

    NASA Technical Reports Server (NTRS)

    Grayson, Gary David (Inventor); Addison, Stephen Michael (Inventor)

    2016-01-01

    A liquid reservoir with a sump includes at least two outlet ports in fluid communication with a fluid conduit. An anti-vortex device includes a first plate extending across the at least two outlet ports and a second plate coupled to the first plate and extending substantially perpendicular to the first plate. The anti-vortex device is configured to disrupt formation of a vortex formed by liquid passing from the reservoir through said outlet ports.

  19. 49 CFR 178.345-11 - Tank outlets.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... unloading of lading, as distinguished from outlets such as manhole covers, vents, vapor recovery devices... away from the loading/unloading outlet. The actuating mechanism must be corrosion-resistant and...

  20. Evaluation of an alternative method for wastewater treatment containing pesticides using solar photocatalytic oxidation and constructed wetlands.

    PubMed

    Berberidou, Chrysanthi; Kitsiou, Vasiliki; Lambropoulou, Dimitra A; Antoniadis, Αpostolos; Ntonou, Eleftheria; Zalidis, George C; Poulios, Ioannis

    2017-06-15

    The present study proposes an integrated system based on the synergetic action of solar photocatalytic oxidation with surface flow constructed wetlands for the purification of wastewater contaminated with pesticides. Experiments were conducted at pilot scale using simulated wastewater containing the herbicide clopyralid. Three photocatalytic methods under solar light were investigated: the photo-Fenton and the ferrioxalate reagent as well as the combination of photo-Fenton with TiO 2 P25, which all led to similar mineralization rates. The subsequent treatment in constructed wetlands resulted in further decrease of DOC and inorganic ions concentrations, especially of NO 3 - . Clopyralid was absent in the outlet of the wetlands, while the concentration of the detected intermediates was remarkably low. These findings are in good agreement with the results of phytotoxicity of the wastewater, after treatment with the ferrioxalate/wetlands process, which was significantly reduced. Thus, this integrated system based on solar photocatalysis and constructed wetlands has the potential to effectively detoxify wastewater containing pesticides, producing a purified effluent which could be exploited for reuse applications. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. 7 CFR 993.108 - Non-human consumption outlet.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ..., that any prunes or prune waste received for a non-human use will be used only within such outlet. [26... 7 Agriculture 8 2012-01-01 2012-01-01 false Non-human consumption outlet. 993.108 Section 993.108... CALIFORNIA Administrative Rules and Regulations Definitions § 993.108 Non-human consumption outlet. Non-human...

  2. 7 CFR 993.108 - Non-human consumption outlet.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ..., that any prunes or prune waste received for a non-human use will be used only within such outlet. [26... 7 Agriculture 8 2014-01-01 2014-01-01 false Non-human consumption outlet. 993.108 Section 993.108... CALIFORNIA Administrative Rules and Regulations Definitions § 993.108 Non-human consumption outlet. Non-human...

  3. A longitudinal analysis of alcohol outlet density and assault.

    PubMed

    Livingston, Michael

    2008-06-01

    The majority of studies that have examined the local-level relationship between alcohol outlet density and violence have utilized cross-sectional data. These studies have consistently demonstrated that there is a spatial link between outlets and violence, but because of their design they have not been able to determine whether changes in outlet density result in changes in rates of violence. The few studies that have examined this question over time have found that the violence rates are related to changes in outlet density. This study provides further evidence of this link and examines the characteristics of regions in which changes in outlet density are most strongly associated with changes in violence rates. The study examined 9 years of data measuring alcohol outlet density (using liquor licensing records) and alcohol-related violence (using police recorded night-time assaults) from 186 postcodes in the metropolitan area of Melbourne, Australia. The relationships between 3 types of alcohol outlet density and alcohol-related violence were assessed using fixed-effects models. The postcodes were then grouped into 5 clusters based on their socio-demographic profile and separate fixed-effects models were fitted to assess whether the relationships between outlets and violence differed based on the type of region being examined. The initial models found overall positive relationships between all 3 types of alcohol outlets and violence. When separate models were developed for postcode clusters, they demonstrated that the link between outlet density and violence was significant in all neighborhood types, but the specific relationships varied substantially. Changes in the number of alcohol outlets in a community are linked to changes in the amount of violence the community experiences. This relationship varies across the clusters of suburbs examined, with packaged liquor outlets consistently associated with violence in suburban areas and general (hotel) and on

  4. Anaerobic treatment of wastewater with high suspended solids from a bulk drug industry using fixed film reactor (AFFR).

    PubMed

    Gangagni Rao, A; Venkata Naidu, G; Krishna Prasad, K; Chandrasekhar Rao, N; Venkata Mohan, S; Jetty, Annapurna; Sarma, P N

    2005-01-01

    Studies were carried out on the treatment of wastewater from a bulk drug industry using an anaerobic fixed film reactor (AFFR) designed and fabricated in the laboratory. The chemical oxygen demand (COD) and total dissolved solids (TDS) of the wastewater were found to be very high with low biochemical oxygen demand (BOD) to COD ratio and high total suspended solid (TSS) concentration. Acclimatization of seed consortia and startup of the reactor was carried out by directly using the wastewater, which resulted in reducing the period of startup to 30 days. The reactor was studied at different organic loading rates (OLR) and it was found that the optimum OLR was 10 kg COD/m(3)/day. The wastewater under investigation, which had a considerable quantity of SS, was treated anaerobically without any pretreatment. COD and BOD of the reactor outlet wastewater were monitored and at steady state and optimum OLR 60-70% of COD and 80-90% of BOD were removed. The reactor was subjected to organic shock loads at two different OLR and the reaction could withstand the shocks and performance could be restored to normalcy at that OLR. The results obtained indicated that AFFR could be used efficiently for the treatment of wastewater from a bulk drug industry having high COD, TDS and TSS.

  5. The Geography of Fast Food Outlets: A Review

    PubMed Central

    Fraser, Lorna K.; Edwards, Kimberly L.; Cade, Janet; Clarke, Graham P.

    2010-01-01

    The availability of food high in fat, salt and sugar through Fast Food (FF) or takeaway outlets, is implicated in the causal pathway for the obesity epidemic. This review aims to summarise this body of research and highlight areas for future work. Thirty three studies were found that had assessed the geography of these outlets. Fourteen studies showed a positive association between availability of FF outlets and increasing deprivation. Another 13 studies also included overweight or obesity data and showed conflicting results between obesity/overweight and FF outlet availability. There is some evidence that FF availability is associated with lower fruit and vegetable intake. There is potential for land use policies to have an influence on the location of new FF outlets. Further research should incorporate good quality data on FF consumption, weight and physical activity. PMID:20623025

  6. The geography of Fast Food outlets: a review.

    PubMed

    Fraser, Lorna K; Edwards, Kimberly L; Cade, Janet; Clarke, Graham P

    2010-05-01

    The availability of food high in fat, salt and sugar through Fast Food (FF) or takeaway outlets, is implicated in the causal pathway for the obesity epidemic. This review aims to summarise this body of research and highlight areas for future work. Thirty three studies were found that had assessed the geography of these outlets. Fourteen studies showed a positive association between availability of FF outlets and increasing deprivation. Another 13 studies also included overweight or obesity data and showed conflicting results between obesity/overweight and FF outlet availability. There is some evidence that FF availability is associated with lower fruit and vegetable intake. There is potential for land use policies to have an influence on the location of new FF outlets. Further research should incorporate good quality data on FF consumption, weight and physical activity.

  7. Alcohol outlet density and assault: a spatial analysis.

    PubMed

    Livingston, Michael

    2008-04-01

    A large number of studies have found links between alcohol outlet densities and assault rates in local areas. This study tests a variety of specifications of this link, focusing in particular on the possibility of a non-linear relationship. Cross-sectional data on police-recorded assaults during high alcohol hours, liquor outlets and socio-demographic characteristics were obtained for 223 postcodes in Melbourne, Australia. These data were used to construct a series of models testing the nature of the relationship between alcohol outlet density and assault, while controlling for socio-demographic factors and spatial auto-correlation. Four types of relationship were examined: a normal linear relationship between outlet density and assault, a non-linear relationship with potential threshold or saturation densities, a relationship mediated by the socio-economic status of the neighbourhood and a relationship which takes into account the effect of outlets in surrounding neighbourhoods. The model positing non-linear relationships between outlet density and assaults was found to fit the data most effectively. An increasing accelerating effect for the density of hotel (pub) licences was found, suggesting a plausible upper limit for these licences in Melbourne postcodes. The study finds positive relationships between outlet density and assault rates and provides evidence that this relationship is non-linear and thus has critical values at which licensing policy-makers can impose density limits.

  8. Validity of Secondary Retail Food Outlet Data

    PubMed Central

    Fleischhacker, Sheila E.; Evenson, Kelly R.; Sharkey, Joseph; Pitts, Stephanie B.J.; Rodriguez, Daniel A.

    2013-01-01

    Context Improving access to healthy foods is a promising strategy to prevent nutrition-related chronic diseases. To characterize retail food environments and identify areas with limited retail access, researchers, government programs, and community advocates have primarily used secondary retail food outlet data sources (e.g., InfoUSA or government food registries). To advance the state of the science on measuring retail food environments, this systematic review examined the evidence for validity reported for secondary retail food outlet data sources for characterizing retail food environments. Evidence acquisition A literature search was conducted through December 31, 2012 to identify peer-reviewed published literature that compared secondary retail food outlet data sources to primary data sources (i.e., field observations) for accuracy of identifying the type and location of retail food outlets. Data were analyzed in 2013. Evidence synthesis Nineteen studies met the inclusion criteria. The evidence for validity reported varied by secondary data sources examined, primary data–gathering approaches, retail food outlets examined, and geographic and sociodemographic characteristics. More than half of the studies (53%) did not report evidence for validity by type of food outlet examined and by a particular secondary data source. Conclusions Researchers should strive to gather primary data but if relying on secondary data sources, InfoUSA and government food registries had higher levels of agreement than reported by other secondary data sources and may provide sufficient accuracy for exploring these associations in large study areas. PMID:24050423

  9. Youth activity spaces and daily exposure to tobacco outlets.

    PubMed

    Lipperman-Kreda, Sharon; Morrison, Christopher; Grube, Joel W; Gaidus, Andrew

    2015-07-01

    We explored whether exposure to tobacco outlets in youths' broader activity spaces differs from that obtained using traditional geographic measures of exposure to tobacco outlet within buffers around homes and schools. Youths completed an initial survey, daily text-prompted surveys, and carried GPS-enabled phones for one week. GPS locations were geocoded and activity spaces were constructed by joining sequential points. We calculated the number of tobacco outlets around these polylines and around homes and schools. Results suggest that activity spaces provide a more accurate measure of tobacco outlet exposures than traditional measures. Assessing tobacco outlet exposure within activity spaces may yield significant information to advance the field. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Tobacco Retail Outlets and Vulnerable Populations in Ontario, Canada

    PubMed Central

    Chaiton, Michael O.; Mecredy, Graham C.; Cohen, Joanna E.; Tilson, Melodie L.

    2013-01-01

    Interest has been increasing in regulating the location and number of tobacco vendors as part of a comprehensive tobacco control program. The objective of this paper is to examine the distribution of tobacco outlets in a large jurisdiction, to assess: (1) whether tobacco outlets are more likely to be located in vulnerable areas; and (2) what proportion of tobacco outlets are located close to schools. Retail locations across the Province of Ontario from Ministry of Health Promotion data were linked to 2006 Census data at the neighbourhood level. There was one tobacco retail outlet for every 1,000 people over age 15 in Ontario. Density of outlets varied by public health unit, and was associated with the number of smokers. Tobacco outlets were more likely to be located in areas that had high neighbourhood deprivation, in both rural and urban areas. Outlets were less likely to be located in areas with high immigrant populations in urban areas, with the reverse being true for rural areas. Overall, 65% of tobacco retailers were located within 500 m of a school. The sale of tobacco products is ubiquitous, however, neighbourhoods with lower socio-economic status are more likely to have easier availability of tobacco products and most retailers are located within walking distance of a school. The results suggest the importance of policies to regulate the location of tobacco retail outlets. PMID:24351748

  11. Evaluation of Heavy Metal Removal from Wastewater in a Modified Packed Bed Biofilm Reactor

    PubMed Central

    Azizi, Shohreh; Kamika, Ilunga; Tekere, Memory

    2016-01-01

    For the effective application of a modified packed bed biofilm reactor (PBBR) in wastewater industrial practice, it is essential to distinguish the tolerance of the system for heavy metals removal. The industrial contamination of wastewater from various sources (e.g. Zn, Cu, Cd and Ni) was studied to assess the impacts on a PBBR. This biological system was examined by evaluating the tolerance of different strengths of composite heavy metals at the optimum hydraulic retention time (HRT) of 2 hours. The heavy metal content of the wastewater outlet stream was then compared to the source material. Different biomass concentrations in the reactor were assessed. The results show that the system can efficiently treat 20 (mg/l) concentrations of combined heavy metals at an optimum HRT condition (2 hours), while above this strength there should be a substantially negative impact on treatment efficiency. Average organic reduction, in terms of the chemical oxygen demand (COD) of the system, is reduced above the tolerance limits for heavy metals as mentioned above. The PBBR biological system, in the presence of high surface area carrier media and a high microbial population to the tune of 10 000 (mg/l), is capable of removing the industrial contamination in wastewater. PMID:27186636

  12. 49 CFR 178.337-8 - Openings, inlets, and outlets.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... used to transport chlorine. The requirements for inlets and outlets on chlorine cargo tanks are in... dioxide, helium, krypton, neon, nitrogen, and xenon, or mixtures thereof. (6) In addition to the internal... equalization of pressure. (b) Inlets and discharge outlets on chlorine tanks. The inlet and discharge outlets...

  13. 49 CFR 178.337-8 - Openings, inlets, and outlets.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... used to transport chlorine. The requirements for inlets and outlets on chlorine cargo tanks are in... dioxide, helium, krypton, neon, nitrogen, and xenon, or mixtures thereof. (6) In addition to the internal... equalization of pressure. (b) Inlets and discharge outlets on chlorine tanks. The inlet and discharge outlets...

  14. 49 CFR 179.100-14 - Bottom outlets.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) SPECIFICATIONS FOR TANK CARS Specifications for Pressure Tank Car Tanks (Classes DOT-105, 109, 112, 114 and 120) § 179.100-14 Bottom outlets. (a) Bottom outlets...

  15. 49 CFR 179.100-14 - Bottom outlets.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) SPECIFICATIONS FOR TANK CARS Specifications for Pressure Tank Car Tanks (Classes DOT-105, 109, 112, 114 and 120) § 179.100-14 Bottom outlets. (a) Bottom outlets...

  16. 49 CFR 179.100-14 - Bottom outlets.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) SPECIFICATIONS FOR TANK CARS Specifications for Pressure Tank Car Tanks (Classes DOT-105, 109, 112, 114 and 120) § 179.100-14 Bottom outlets. (a) Bottom outlets...

  17. Tobacco Retail Outlet Density and Young Adult Tobacco Initiation

    PubMed Central

    Pearson, Jennifer L.; Anesetti-Rothermel, Andrew; Xiao, Haijun; Kirchner, Thomas R.; Vallone, Donna

    2016-01-01

    Background: A growing body of evidence indicates that the density of tobacco retail outlets around the home residence may influence tobacco use among youth and adults. The purpose of this study was to examine the impact of neighborhood tobacco retail outlet density on young adult initiation of different tobacco product types. Methods: Cross-sectional data from a 2013 nationally representative sample of young adults aged 18–34 was examined in relation to a 2012 geocoded listing of all outlets likely to sell tobacco in the United States. Separate multivariable logistic regression analyses examined associations between neighborhood outlet density and past 6 months first use of cigarettes, non-cigarette combustible products, and noncombustible products among adults aged 18–24 and 25–34. Results: Outlet density was significantly associated with recent initiation of cigarettes and other combustibles, but this impact varied for younger and older groups. Increased density was significantly associated with a higher likelihood of initiating cigarette use among adults aged 25–34 (OR = 3.75, 95% CI = 1.18, 11.90), and of initiating non-cigarette combustible use among 18–24 year olds (OR = 3.16, 95% CI = 1.03, 9.74). There was no impact of outlet density on recent noncombustible product initiation among either group. Conclusion: This study is the first to examine the impact of tobacco outlet density on young adult initiation of cigarettes and other tobacco products. Findings demonstrate that residential neighborhood outlet density is associated with recent initiation of combustible products and this effect varies by product type and age. The tobacco outlet environment may be a critical factor in promoting young adult tobacco use initiation. PMID:25666816

  18. Relating Off-Premises Alcohol Outlet Density to Intentional and Unintentional Injuries

    PubMed Central

    Morrison, Christopher; Smith, Karen; Gruenewald, Paul J.; Ponicki, William R.; Lee, Juliet P.; Cameron, Peter

    2015-01-01

    Aims This study investigated the hypotheses that (i) intentional and unintentional injuries occur more frequently in areas with greater density of off-premises alcohol outlets; and (ii) larger and chain outlets selling cheaper alcohol contribute more substantially to injury risk than smaller and independent outlets. Design Ecological cross-sectional. Setting From the 256 Statistical Area level 2 (SA2) Census units in Melbourne, Australia, we selected a random sample of 62 units. There were 2,119 Statistical Area level 1 (SA1) units nested within the selected SA2 units. Participants The selected units contained 295 off-premises outlets. Measurements Two independent observers conducted premises assessments in all off-premises outlets, assessing the volume of alcohol available for sale (paces of shelf space), price (least wine price), and other operating characteristics (chain vs. independent, drive-through). Outlet counts, assessed outlet characteristics, and other area characteristics (population density, median age, median income, retail zoning) were aggregated within SA1 units. Dependent variables were counts of ambulance attended intentional injuries (assaults, stabbings, shootings) and unintentional injuries (falls, crush injuries, and object strikes). Findings In univariable analyses, chain outlets were larger (r = 0.383; p < 0.001) and sold cheaper alcohol (r = −0.484; p < 0.001) compared with independent outlets. In Bayesian spatial Poisson models, off-premises outlet density was positively related to both intentional (Incidence Rate Ratio = 1.38; 95% Credible Interval: 1.19, 1.60) and unintentional injuries (IRR = 1.18; 95% CI: 1.06, 1.30). After disaggregation by outlet characteristics, chain outlet density was also related to both intentional (IRR = 1.35; 95% CI: 1.11, 1.64) and unintentional injuries (IRR = 1.20; 95% CI: 1.08, 1.38). Conclusions Greater off-premises outlet density is related to greater incidence of traumatic injury, and chain outlets

  19. 46 CFR 193.15-25 - Discharge outlets.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 7 2013-10-01 2013-10-01 false Discharge outlets. 193.15-25 Section 193.15-25 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide and Clean Agent Extinguishing Systems, Details § 193.15-25 Discharge outlets. (a...

  20. 46 CFR 193.15-25 - Discharge outlets.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 7 2014-10-01 2014-10-01 false Discharge outlets. 193.15-25 Section 193.15-25 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide and Clean Agent Extinguishing Systems, Details § 193.15-25 Discharge outlets. (a...

  1. Anaerobic treatment of wastewater with high suspended solids from a bulk drug industry using fixed film reactor (AFFR).

    PubMed

    Rao, A Gangagni; Naidu, G Venkata; Prasad, K Krishna; Rao, N Chandrasekhar; Mohan, S Venkata; Jetty, Annapurna; Sarma, P N

    2004-07-01

    Studies are carried out on the treatment of wastewater from a bulk drug industry using an anaerobic fixed film reactor (AFFR) designed and fabricated in the laboratory. The chemical oxygen demand (COD) and total dissolved solids (TDS) of the wastewater are found to be very high with low Biochemical oxygen demand (BOD) to COD ratio and high total suspended solid (TSS) concentration. Acclimatization of seed consortia and start up of the reactor is carried out by directly using the wastewater, which resulted in reducing the period of startup to 30 days. The reactor is studied at different organic loading rates (OLR) and it is found that the optimum OLR is 10 kg COD/m3/day. The wastewater under investigation, which is having considerable quantity of SS, is treated anaerobically without any pretreatment. The COD and BOD of the reactor outlet wastewater are monitored and reduction at steady state and optimum OLR is observed to be 60-70% of COD and 80-90% of BOD. The reactor is subjected to organic shock loads at two different OLR and it is observed that the reactor could withstand shocks and performance could be restored to normalcy at that OLR. The results obtained indicated that AFFR could be used efficiently for the treatment of wastewater from a bulk drug industry having high COD, TDS and TSS. Copyright 2003 Elsevier Ltd.

  2. Removal of pharmaceuticals in conventionally treated wastewater by a polishing moving bed biofilm reactor (MBBR) with intermittent feeding.

    PubMed

    Tang, Kai; Ooi, Gordon T H; Litty, Klaus; Sundmark, Kim; Kaarsholm, Kamilla M S; Sund, Christina; Kragelund, Caroline; Christensson, Magnus; Bester, Kai; Andersen, Henrik R

    2017-07-01

    Previous studies have demonstrated that aerobic moving bed biofilm reactors (MBBRs) remove pharmaceuticals better than activated sludge. Thus we used a MBBR system to polish the effluent of an activated sludge wastewater treatment plant. To overcome that effluent contains insufficient organic matter to sustain enough biomass, the biofilm was intermittently fed with raw wastewater. The capacity of pharmaceutical degradation was investigated by spiking pharmaceuticals. Actual removal during treatment was assessed by sampling the inlets and outlets of reactors. The removal of the majority of pharmaceuticals was enhanced through the intermittent feeding of the MBBR. First-order rate constants for pharmaceutical removal, normalised to biomass, were significantly higher compared to other studies on activated sludge and suspended biofilms, especially for diclofenac, metoprolol and atenolol. Due to the intermittently feeding, degradation of diclofenac occurred with a half-life of only 2.1h and was thus much faster than any hitherto described wastewater bioreactor treatment. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. 5 CFR 591.217 - In which outlets does OPM collect prices?

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... popular outlets in each survey area. OPM selects these outlets based on their proximity to the housing... that reflect sales volume. To the extent practical, OPM prices like items in the same types of outlets... surveys and select outlets based on the results of those surveys. ...

  4. Availability of limited service food outlets surrounding schools in British Columbia.

    PubMed

    Black, Jennifer L; Day, Meghan

    2012-06-05

    The purpose of this study was to provide a descriptive profile of the availability of limited service food outlets surrounding public schools in British Columbia, Canada. Data from the 2010 Canadian Business Data Files were used to identify limited service food outlets including fast food outlets, beverage and snack food stores, delis and convenience stores. The number of food outlets within 800 metres of 1,392 public schools and the distance from schools to the nearest food outlets were assessed. Multivariate regression models examined the associations between food outlet availability and school-level characteristics. In 2010, over half of the public schools in BC (54%) were located within a 10-12 minute walk from at least one limited service food outlet. The median closest distance to a food outlet was just over 1 km (1016 m). Schools comprised of students living in densely populated urban neighbourhoods and neighbourhoods characterized by lower socio-economic status were more likely to have access to limited service food outlets within walking distance. After adjusting for school-level median family income and population density, larger schools had higher odds of exposure to food vendors compared to schools with fewer students. The availability of and proximity to limited service food outlets vary widely across schools in British Columbia and school-level characteristics are significantly associated with food outlet availability. Additional research is needed to understand how food environment exposures inside and surrounding schools impact students' attitudes, food choices and dietary quality.

  5. Relating off-premises alcohol outlet density to intentional and unintentional injuries.

    PubMed

    Morrison, Christopher; Smith, Karen; Gruenewald, Paul J; Ponicki, William R; Lee, Juliet P; Cameron, Peter

    2016-01-01

    This study investigated the hypotheses that (i) intentional and unintentional injuries occur more frequently in areas with greater density of off-premises alcohol outlets; and (ii) larger and chain outlets selling cheaper alcohol contribute more substantially to injury risk than smaller and independent outlets. Ecological cross-sectional. From the 256 Statistical Area level 2 (SA2) census units in Melbourne, Australia, we selected a random sample of 62 units. There were 2119 Statistical Area level 1 (SA1) units nested within the selected SA2 units. The selected units contained 295 off-premises outlets. Two independent observers conducted premises assessments in all off-premises outlets, assessing the volume of alcohol available for sale (paces of shelf space), price (least wine price) and other operating characteristics (chain versus independent, drive-through). Outlet counts, assessed outlet characteristics and other area characteristics (population density, median age, median income, retail zoning) were aggregated within SA1 units. Dependent variables were counts of ambulance attended intentional injuries (assaults, stabbings, shootings) and unintentional injuries (falls, crush injuries and object strikes). In univariable analyses, chain outlets were larger (r = 0.383; P < 0.001) and sold cheaper alcohol (r = -0.484; P < 0.001) compared with independent outlets. In Bayesian spatial Poisson models, off-premises outlet density was positively related to both intentional [incidence rate ratio (IRR) = 1.38; 95% credible interval (CI) = 1.19, 1.60] and unintentional injuries (IRR = 1.18; 95% CI = 1.06, 1.30). After disaggregation by outlet characteristics, chain outlet density was also related to both intentional (IRR = 1.35; 95% CI = 1.11, 1.64) and unintentional injuries (IRR = 1.20; 95% CI = 1.08, 1.38). Greater off-premises outlet density is related to greater incidence of traumatic injury, and chain outlets appear to

  6. 14 CFR 29.977 - Fuel tank outlet.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Fuel System § 29.977 Fuel tank outlet. (a) There must be... airplanes, prevent the passage of any object that could restrict fuel flow or damage any fuel system... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Fuel tank outlet. 29.977 Section 29.977...

  7. 14 CFR 25.977 - Fuel tank outlet.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Fuel System § 25.977 Fuel tank outlet. (a) There must be... airplanes, prevent the passage of any object that could restrict fuel flow or damage any fuel system... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Fuel tank outlet. 25.977 Section 25.977...

  8. 14 CFR 23.977 - Fuel tank outlet.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Powerplant Fuel System § 23.977 Fuel... damage any fuel system component. (b) The clear area of each fuel tank outlet strainer must be at least... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Fuel tank outlet. 23.977 Section 23.977...

  9. 14 CFR 23.977 - Fuel tank outlet.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Powerplant Fuel System § 23.977 Fuel... damage any fuel system component. (b) The clear area of each fuel tank outlet strainer must be at least... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Fuel tank outlet. 23.977 Section 23.977...

  10. 14 CFR 29.977 - Fuel tank outlet.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Fuel System § 29.977 Fuel tank outlet. (a) There must be... airplanes, prevent the passage of any object that could restrict fuel flow or damage any fuel system... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Fuel tank outlet. 29.977 Section 29.977...

  11. 14 CFR 25.977 - Fuel tank outlet.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Fuel System § 25.977 Fuel tank outlet. (a) There must be... airplanes, prevent the passage of any object that could restrict fuel flow or damage any fuel system... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Fuel tank outlet. 25.977 Section 25.977...

  12. 14 CFR 25.977 - Fuel tank outlet.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Fuel System § 25.977 Fuel tank outlet. (a) There must be... airplanes, prevent the passage of any object that could restrict fuel flow or damage any fuel system... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Fuel tank outlet. 25.977 Section 25.977...

  13. 14 CFR 29.977 - Fuel tank outlet.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Fuel System § 29.977 Fuel tank outlet. (a) There must be... airplanes, prevent the passage of any object that could restrict fuel flow or damage any fuel system... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Fuel tank outlet. 29.977 Section 29.977...

  14. 14 CFR 29.977 - Fuel tank outlet.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Fuel System § 29.977 Fuel tank outlet. (a) There must be... airplanes, prevent the passage of any object that could restrict fuel flow or damage any fuel system... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel tank outlet. 29.977 Section 29.977...

  15. 14 CFR 25.977 - Fuel tank outlet.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Fuel System § 25.977 Fuel tank outlet. (a) There must be... airplanes, prevent the passage of any object that could restrict fuel flow or damage any fuel system... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel tank outlet. 25.977 Section 25.977...

  16. 14 CFR 23.977 - Fuel tank outlet.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Powerplant Fuel System § 23.977 Fuel... damage any fuel system component. (b) The clear area of each fuel tank outlet strainer must be at least... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel tank outlet. 23.977 Section 23.977...

  17. 14 CFR 25.977 - Fuel tank outlet.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Fuel System § 25.977 Fuel tank outlet. (a) There must be... airplanes, prevent the passage of any object that could restrict fuel flow or damage any fuel system... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Fuel tank outlet. 25.977 Section 25.977...

  18. 14 CFR 23.977 - Fuel tank outlet.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Powerplant Fuel System § 23.977 Fuel... damage any fuel system component. (b) The clear area of each fuel tank outlet strainer must be at least... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Fuel tank outlet. 23.977 Section 23.977...

  19. 14 CFR 23.977 - Fuel tank outlet.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Powerplant Fuel System § 23.977 Fuel... damage any fuel system component. (b) The clear area of each fuel tank outlet strainer must be at least... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Fuel tank outlet. 23.977 Section 23.977...

  20. 14 CFR 29.977 - Fuel tank outlet.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Fuel System § 29.977 Fuel tank outlet. (a) There must be... airplanes, prevent the passage of any object that could restrict fuel flow or damage any fuel system... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Fuel tank outlet. 29.977 Section 29.977...

  1. Bladder outlet obstruction in women: definition and characteristics.

    PubMed

    Groutz, A; Blaivas, J G; Chaikin, D C

    2000-01-01

    The prevalence of bladder outlet obstruction in women is unknown and most probably has been underestimated. Moreover, there are no standard definitions for the diagnosis of bladder outlet obstruction in women. Our study was conducted to define as well as to examine the clinical and urodynamic characteristics of bladder outlet obstruction among women referred for evaluation of voiding symptoms. Bladder outlet obstruction was defined as a persistent, low, maximum "free" flow rate of <12 mL/s in repeated non-invasive uroflow studies, combined with high detrusor pressure at a maximum flow (p(det.Q)(max) >20 cm H(2)O) during detrusor pressure-uroflow studies. A urodynamic database of 587 consecutive women identified 38 (6.5%) women with bladder outlet obstruction. The mean age of the patients was 63.9 +/- 17.5 years. The mean maximum "free" flow, voided volume, and residual urinary volume were 9.4 +/-3.9 mL/s, 144. 9 +/- 72.7 mL, and 86.1 +/- 98.8 mL, respectively. The mean p(det. Q)(max) was 37.2 +/- 19.2 cm H(2)O. Previous anti-incontinence surgery and severe genital prolapse were the most common etiologies, accounting for half of the cases. Other, less common, etiologies included urethral stricture (13%), primary bladder neck obstruction (8%), learned voiding dysfunction (5%), and detrusor external sphincter dyssynergia (5%). Symptomatology was defined as mixed obstructive and irritative in 63% of the patients, isolated irritative in 29%, and isolated obstructive in other 8%. In conclusion, bladder outlet obstruction in women appears to be more common than was previously recognized, occurring in 6.5% of our patients. Micturition symptoms relevant to bladder outlet obstruction are non-specific, and a full urodynamic evaluation is essential in making the correct diagnosis and formulating a treatment plan.

  2. Social disadvantage and exposure to lower priced alcohol in off-premise outlets.

    PubMed

    Morrison, Christopher; Ponicki, William R; Smith, Karen

    2015-07-01

    Greater concentrations of off-premise alcohol outlets are found in areas of social disadvantage, exposing disadvantaged populations to excess risk for problems such as assault, child abuse and intimate partner violence. This study examines whether the outlets to which they are exposed also sell cheaper alcohol, potentially further contributing to income-related health disparities. We conducted unobtrusive observations in 295 off-premise outlets in Melbourne, Australia, randomly selected using a spatial sample frame. In semi-logged linear regression models, we related the minimum purchase price for a 750 mL bottle of wine to a national index of socioeconomic advantage for the census areas in which the outlets were located. Other independent variables characterised outlet features (e.g. volume, chain management) and conditions of the local alcohol market (adjacent outlet characteristics, neighbourhood characteristics). A one decile increase in socioeconomic advantage was related to a 1.3% increase in logged price. Larger outlets, chains, outlets adjacent to chains, outlets in greater proximity to the nearest neighbouring outlet and those located in areas with more students also had cheaper alcohol. Not only are disadvantaged populations exposed to more outlets, the outlets to which they are exposed sell cheaper alcohol. This finding appears to be consistent with the spatial dynamics of typical retail markets. © 2015 Australasian Professional Society on Alcohol and other Drugs.

  3. Social Disadvantage and Exposure to Lower Priced Alcohol in Off-Premise Outlets

    PubMed Central

    Morrison, Christopher; Ponicki, William R; Smith, Karen

    2015-01-01

    Introduction and Aims Greater concentrations of off-premise alcohol outlets are found in areas of social disadvantage, exposing disadvantaged populations to excess risk for problems such as assault, child abuse and intimate partner violence. This study examines whether the outlets to which they are exposed also sell cheaper alcohol, potentially further contributing to income-related health disparities. Design and Methods We conducted unobtrusive observations in 295 off-premise outlets in Melbourne, Australia, randomly selected using a spatial sample frame. In semi-logged linear regression models we related the minimum purchase price for a 750ml bottle of wine to a national index of socio-economic advantage for the Census areas in which the outlets were located. Other independent variables characterised outlet features (e.g., volume, chain management) and conditions of the local alcohol market (adjacent outlet characteristics, neighbourhood characteristics). Results A one decile increase in socio-economic advantage was related to a 1.3% increase in logged price. Larger outlets, chains, outlets adjacent to chains, outlets in greater proximity to the nearest neighbouring outlet, those located in areas with more students also had cheaper alcohol. Discussion and Conclusions Not only are disadvantaged populations exposed to more outlets, the outlets to which they are exposed sell cheaper alcohol. This finding appears to be consistent with the spatial dynamics of typical retail markets. PMID:25808717

  4. 49 CFR 178.345-11 - Tank outlets.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 3 2012-10-01 2012-10-01 false Tank outlets. 178.345-11 Section 178.345-11... Containers for Motor Vehicle Transportation § 178.345-11 Tank outlets. (a) General. As used in this section, “loading/unloading outlet” means any opening in the cargo tank wall used for loading or unloading of lading...

  5. 49 CFR 178.345-11 - Tank outlets.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 3 2013-10-01 2013-10-01 false Tank outlets. 178.345-11 Section 178.345-11... Containers for Motor Vehicle Transportation § 178.345-11 Tank outlets. (a) General. As used in this section, “loading/unloading outlet” means any opening in the cargo tank wall used for loading or unloading of lading...

  6. 49 CFR 178.345-11 - Tank outlets.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 3 2014-10-01 2014-10-01 false Tank outlets. 178.345-11 Section 178.345-11... Containers for Motor Vehicle Transportation § 178.345-11 Tank outlets. (a) General. As used in this section, “loading/unloading outlet” means any opening in the cargo tank wall used for loading or unloading of lading...

  7. 49 CFR 178.345-11 - Tank outlets.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false Tank outlets. 178.345-11 Section 178.345-11... Containers for Motor Vehicle Transportation § 178.345-11 Tank outlets. (a) General. As used in this section, “loading/unloading outlet” means any opening in the cargo tank wall used for loading or unloading of lading...

  8. 49 CFR 179.220-18 - Bottom outlets.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...-shaped breakage groove shall be cut (not cast) in the upper part of the outlet nozzle at a point... nozzle extends below the bottom of the outer shell, a V-shaped breakage groove shall be cut (not cast) in... projection of the bottom outlet equipment may not be more than that allowed by appendix E of the AAR...

  9. Enhancement of Micropollutant Degradation at the Outlet of Small Wastewater Treatment Plants

    PubMed Central

    Rossi, Luca; Queloz, Pierre; Brovelli, Alessandro; Margot, Jonas; Barry, D. A.

    2013-01-01

    The aim of this work was to evaluate low-cost and easy-to-operate engineering solutions that can be added as a polishing step to small wastewater treatment plants to reduce the micropollutant load to water bodies. The proposed design combines a sand filter/constructed wetland with additional and more advanced treatment technologies (UV degradation, enhanced adsorption to the solid phase, e.g., an engineered substrate) to increase the elimination of recalcitrant compounds. The removal of five micropollutants with different physico-chemical characteristics (three pharmaceuticals: diclofenac, carbamazepine, sulfamethoxazole, one pesticide: mecoprop, and one corrosion inhibitor: benzotriazole) was studied to evaluate the feasibility of the proposed system. Separate batch experiments were conducted to assess the removal efficiency of UV degradation and adsorption. The efficiency of each individual process was substance-specific. No process was effective on all the compounds tested, although elimination rates over 80% using light expanded clay aggregate (an engineered material) were observed. A laboratory-scale flow-through setup was used to evaluate interactions when removal processes were combined. Four of the studied compounds were partially eliminated, with poor removal of the fifth (benzotriazole). The energy requirements for a field-scale installation were estimated to be the same order of magnitude as those of ozonation and powdered activated carbon treatments. PMID:23484055

  10. Scour at culvert outlets in mixed bed materials.

    DOT National Transportation Integrated Search

    1982-09-01

    "The study of localized scour at culvert outlets has been on-going to control and manage erosion along highway embankments. Herein is presented an investigation of scour at culvert outlets which refines and extends the state-of-the-art of predicting ...

  11. Plug into a Great Outlet for Creativity

    ERIC Educational Resources Information Center

    Skophammer, Karen

    2009-01-01

    Is there beauty in the wall socket that people plug their appliances into daily? Can one find beauty in the grate covering the heat vent in his classroom? The author posed these very questions to her third-grade students. She had the students take a good look at the outlet cover (or plate) on the wall. After thinking and discussing the outlets,…

  12. Community organization moderates the effect of alcohol outlet density on violence.

    PubMed

    Pridemore, William Alex; Grubesic, Tony H

    2012-12-01

    There is growing evidence from multiple disciplines that alcohol outlet density is associated with community levels of assault. Based on the theoretical and empirical literatures on social organization and crime, we tested the hypothesis that the association between alcohol outlet density and neighbourhood violence rates is moderated by social organization. Using geocoded police data on assaults, geocoded data on the location of alcohol outlets, and controlling for several structural factors thought to be associated with violence rates, we tested this hypothesis employing negative binomial regression with our sample of 298 block groups in Cincinnati. Our results revealed direct effects of alcohol outlet density and social organization on assault density, and these effects held for different outlet types (i.e., off-premise, bars, restaurants) and levels of harm (i.e., simple and aggravated assaults). More importantly, we found that the strength of the outlet-assault association was significantly weaker in more socially organized communities. Subsequent analyses by level of organization revealed no effects of alcohol outlet density on aggravated assaults in organized block groups, but significant effects in disorganized block groups. We found no association between social (dis)organization and outlet density. These results clarify the community-level relationship between alcohol outlets and violence and have important implications for municipal-level alcohol policies. © London School of Economics and Political Science 2012.

  13. Underage purchasing of alcohol from packaged liquor outlets: an Australian study.

    PubMed

    Rowland, Bosco C; Hall, Jessica K; Kremer, Peter J; Miller, Peter G; Toumbourou, John W

    2017-10-01

    Access to the supply of alcohol is an important factor influencing adolescent alcohol consumption. Although alcohol sales outlets are prohibited from selling alcohol to underage youth, there has been limited research investigating compliance. The present study sought to estimate the extent to which adolescents that appeared underage were successfully able to purchase alcohol from packaged liquor outlets in Australia; and to identify store and sales characteristics associated with illegal purchasing. In 2012, purchase surveys were conducted (n= 310) at packaged liquor outlets in 28 urban and rural communities across three states of Australia: Western Australia, Queensland and Victoria. Confederates successfully purchased alcohol at 60% (95% CI: 55-66) of outlets. The density of general alcohol outlets in the surrounding area and the type of liquor outlet were predictors of successful alcohol purchases; however, this was moderated by the state in which the purchase was made. Regional geographical location was also found to predict underage alcohol purchase. The majority of alcohol sales outlets in Australia breach regulations prohibiting sales to underage youth. Consistent enforcement of policies across the states of Australia, and reducing the number of alcohol outlets, will help prevent alcohol outlets illegally selling alcohol to underage adolescents. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  14. Alcohol beverage control, privatization and the geographic distribution of alcohol outlets

    PubMed Central

    2012-01-01

    Background With Pennsylvania currently considering a move away from an Alcohol Beverage Control state to a privatized alcohol distribution system, this study uses a spatial analytical approach to examine potential impacts of privatization on the number and spatial distribution of alcohol outlets in the city of Philadelphia over a long time horizon. Methods A suite of geospatial data were acquired for Philadelphia, including 1,964 alcohol outlet locations, 569,928 land parcels, and school, church, hospital, park and playground locations. These data were used as inputs for exploratory spatial analysis to estimate the expected number of outlets that would eventually operate in Philadelphia. Constraints included proximity restrictions (based on current ordinances regulating outlet distribution) of at least 200 feet between alcohol outlets and at least 300 feet between outlets and schools, churches, hospitals, parks and playgrounds. Results Findings suggest that current state policies on alcohol outlet distributions in Philadelphia are loosely enforced, with many areas exhibiting extremely high spatial densities of outlets that violate existing proximity restrictions. The spatial model indicates that an additional 1,115 outlets could open in Philadelphia if privatization was to occur and current proximity ordinances were maintained. Conclusions The study reveals that spatial analytical approaches can function as an excellent tool for contingency-based “what-if” analysis, providing an objective snapshot of potential policy outcomes prior to implementation. In this case, the likely outcome is a tremendous increase in alcohol outlets in Philadelphia, with concomitant negative health, crime and quality of life outcomes that accompany such an increase. PMID:23170899

  15. Alcohol outlet density and violence: a geospatial analysis.

    PubMed

    Zhu, L; Gorman, D M; Horel, S

    2004-01-01

    To examine the relationship between alcohol outlet density and violent crime controlling for neighbourhood sociostructural characteristics and the effects of spatially autocorrelated error. The sample for this ecologic study comprised 188 census tracts from the City of Austin, Texas and 263 tracts from the City of San Antonio, Texas. Data pertaining to neighbourhood social structure, alcohol density and violent crime were collected from archival sources, and analysed using bivariate, multivariate and geospatial analyses. Using ordinary least squares analysis, the neighbourhood sociostructural covariates explained close to 59% of the variability in violent crime rates in Austin and close to 39% in San Antonio. Adding alcohol outlet density in the target and adjacent census tracts improved the explanatory power of both models. Alcohol outlet density in the target census tract remained a significant predictor of violent crime rates in both cities when the effects of autocorrelated error were controlled for. In Austin, the effects of alcohol outlet density in the adjacent census tracts also remained significant. The final model explains 71% of the variance in violent crime in Austin and 56% in San Antonio. The findings show a clear association between alcohol outlet density and violence, and suggest that the issues of alcohol availability and access are fundamental to the prevention of alcohol-related problems within communities.

  16. Ecological Associations of Alcohol Outlets with Underage and Young Adult Injuries

    PubMed Central

    Gruenewald, Paul J.; Freisthler, Bridget; Remer, Lillian; LaScala, Elizabeth A.; Treno, Andrew J.; Ponicki, William R.

    2010-01-01

    Objective This paper argues that associations between rates of three specific problems related to alcohol (i.e., accidents, traffic crashes, and assaults) should be differentially related to densities of off-premise outlets among underage youth and young adults based upon age related-patterns of alcohol outlet use. Methods Zip code-level population models assessed local and distal effects of alcohol outlets upon rates of hospital discharges for these outcomes. Results Densities of off-premise alcohol outlets were significantly related to injuries from accidents, assaults, and traffic crashes for both underage youth and young adults. Densities of bars were associated with more assaults and densities of restaurants were associated with more traffic crash injuries for young adults. Conclusions The distribution of alcohol-related injuries relative to alcohol outlets reflect patterns of alcohol outlet use. PMID:20028361

  17. Impact assessment of treated/untreated wastewater toxicants discharged by sewage treatment plants on health, agricultural, and environmental quality in the wastewater disposal area.

    PubMed

    Singh, Kunwar P; Mohan, Dinesh; Sinha, Sarita; Dalwani, R

    2004-04-01

    Studies were undertaken to assess the impact of wastewater/sludge disposal (metals and pesticides) from sewage treatment plants (STPs) in Jajmau, Kanpur (5 MLD) and Dinapur, Varanasi (80 MLD), on health, agriculture and environmental quality in the receiving/application areas around Kanpur and Varanasi in Uttar Pradesh, India. The raw, treated and mixed treated urban wastewater samples were collected from the inlet and outlet points of the plants during peak (morning and evening) and non-peak (noon) hours. The impact of the treated wastewater toxicants (metals and pesticides) on the environmental quality of the disposal area was assessed in terms of their levels in different media samples viz., water, soil, crops, vegetation, and food grains. The data generated show elevated levels of metals and pesticides in all the environmental media, suggesting a definite adverse impact on the environmental quality of the disposal area. The critical levels of the heavy metals in the soil for agricultural crops are found to be much higher than those observed in the study areas receiving no effluents. The sludge from the STPs has both positive and negative impacts on agriculture as it is loaded with high levels of toxic heavy metals and pesticides, but also enriched with several useful ingredients such as N, P, and K providing fertilizer values. The sludge studied had cadmium, chromium and nickel levels above tolerable levels as prescribed for agricultural and lands application. Bio-monitoring of the metals and pesticides levels in the human blood and urine of the different population groups under study areas was undertaken. All the different approaches indicated a considerable risk and impact of heavy metals and pesticides on human health in the exposed areas receiving the wastewater from the STPs.

  18. 7 CFR 929.57 - Outlets for restricted cranberries.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 8 2013-01-01 2013-01-01 false Outlets for restricted cranberries. 929.57 Section 929... SERVICE (MARKETING AGREEMENTS AND ORDERS; FRUITS, VEGETABLES, NUTS), DEPARTMENT OF AGRICULTURE CRANBERRIES....57 Outlets for restricted cranberries. (a) Except as provided in this section and in § 929.56...

  19. 7 CFR 929.57 - Outlets for restricted cranberries.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 8 2011-01-01 2011-01-01 false Outlets for restricted cranberries. 929.57 Section 929... SERVICE (Marketing Agreements and Orders; Fruits, Vegetables, Nuts), DEPARTMENT OF AGRICULTURE CRANBERRIES....57 Outlets for restricted cranberries. (a) Except as provided in this section and in § 929.56...

  20. 7 CFR 929.57 - Outlets for restricted cranberries.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 8 2014-01-01 2014-01-01 false Outlets for restricted cranberries. 929.57 Section 929... SERVICE (MARKETING AGREEMENTS AND ORDERS; FRUITS, VEGETABLES, NUTS), DEPARTMENT OF AGRICULTURE CRANBERRIES....57 Outlets for restricted cranberries. (a) Except as provided in this section and in § 929.56...

  1. 7 CFR 929.61 - Outlets for excess cranberries.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 8 2012-01-01 2012-01-01 false Outlets for excess cranberries. 929.61 Section 929.61... Agreements and Orders; Fruits, Vegetables, Nuts), DEPARTMENT OF AGRICULTURE CRANBERRIES GROWN IN STATES OF... excess cranberries. (a) Noncommercial outlets. Excess cranberries may be disposed of in noncommercial...

  2. 7 CFR 929.61 - Outlets for excess cranberries.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 8 2013-01-01 2013-01-01 false Outlets for excess cranberries. 929.61 Section 929.61... AGREEMENTS AND ORDERS; FRUITS, VEGETABLES, NUTS), DEPARTMENT OF AGRICULTURE CRANBERRIES GROWN IN STATES OF... excess cranberries. (a) Noncommercial outlets. Excess cranberries may be disposed of in noncommercial...

  3. 7 CFR 929.61 - Outlets for excess cranberries.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 8 2014-01-01 2014-01-01 false Outlets for excess cranberries. 929.61 Section 929.61... AGREEMENTS AND ORDERS; FRUITS, VEGETABLES, NUTS), DEPARTMENT OF AGRICULTURE CRANBERRIES GROWN IN STATES OF... excess cranberries. (a) Noncommercial outlets. Excess cranberries may be disposed of in noncommercial...

  4. 7 CFR 929.61 - Outlets for excess cranberries.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 8 2011-01-01 2011-01-01 false Outlets for excess cranberries. 929.61 Section 929.61... Agreements and Orders; Fruits, Vegetables, Nuts), DEPARTMENT OF AGRICULTURE CRANBERRIES GROWN IN STATES OF... excess cranberries. (a) Noncommercial outlets. Excess cranberries may be disposed of in noncommercial...

  5. 7 CFR 929.57 - Outlets for restricted cranberries.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Outlets for restricted cranberries. 929.57 Section 929... SERVICE (Marketing Agreements and Orders; Fruits, Vegetables, Nuts), DEPARTMENT OF AGRICULTURE CRANBERRIES....57 Outlets for restricted cranberries. (a) Except as provided in this section and in § 929.56...

  6. 7 CFR 929.57 - Outlets for restricted cranberries.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 8 2012-01-01 2012-01-01 false Outlets for restricted cranberries. 929.57 Section 929... SERVICE (Marketing Agreements and Orders; Fruits, Vegetables, Nuts), DEPARTMENT OF AGRICULTURE CRANBERRIES....57 Outlets for restricted cranberries. (a) Except as provided in this section and in § 929.56...

  7. Influence of cold storage prior to and after ripening on quality factors and sensory attributes of ‘Hass’ avocados

    USDA-ARS?s Scientific Manuscript database

    Partially-ripened avocados are often held in cold storage in an attempt to enable the consistent delivery of ripe fruit to food service or retail outlets, although the effect on the quality of such fruit is incompletely understood. ‘Hass’ avocados were ripened to near ripeness (13.3 - 17.8 N) at 20 ...

  8. 46 CFR 111.79-1 - Receptacle outlets; general.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Receptacle outlets; general. 111.79-1 Section 111.79-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Receptacles § 111.79-1 Receptacle outlets; general. (a) There must be a sufficient...

  9. 46 CFR 111.79-1 - Receptacle outlets; general.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Receptacle outlets; general. 111.79-1 Section 111.79-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Receptacles § 111.79-1 Receptacle outlets; general. (a) There must be a sufficient...

  10. 46 CFR 111.79-1 - Receptacle outlets; general.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Receptacle outlets; general. 111.79-1 Section 111.79-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Receptacles § 111.79-1 Receptacle outlets; general. (a) There must be a sufficient...

  11. 46 CFR 111.79-1 - Receptacle outlets; general.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Receptacle outlets; general. 111.79-1 Section 111.79-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Receptacles § 111.79-1 Receptacle outlets; general. (a) There must be a sufficient...

  12. 46 CFR 111.79-1 - Receptacle outlets; general.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Receptacle outlets; general. 111.79-1 Section 111.79-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Receptacles § 111.79-1 Receptacle outlets; general. (a) There must be a sufficient...

  13. AGU hydrology publication outlets

    NASA Astrophysics Data System (ADS)

    Freeze, R. Allan

    In recent months I have been approached on several occasions by members of the hydrology community who asked me which of the various AGU journals and publishing outlets would be most suitable for a particular paper or article that they have prepared.Water Resources Research (WRR) is the primary AGU outlet for research papers in hydrology. It is an interdisciplinary journal that integrates research in the social and natural sciences of water. The editors of WRR invite original contributions in the physical, chemical and biological sciences and also in the social and policy sciences, including economics, systems analysis, sociology, and law. The editor for the physical sciences side of the journal is Donald R. Nielson, LAWR Veihmeyer Hall, University of California Davis, Davis, CA 95616. The editor for the policy sciences side of the journal is Ronald G. Cummings, Department of Economics, University of New Mexico, Albuquerque, NM 87131

  14. Acute Alcohol Consumption, Alcohol Outlets, and Gun Suicide

    PubMed Central

    Branas, Charles C.; Richmond, Therese S.; Ten Have, Thomas R.; Wiebe, Douglas J.

    2014-01-01

    A case–control study of 149 intentionally self-inflicted gun injury cases (including completed gun suicides) and 302 population-based controls was conducted from 2003 to 2006 in a major US city. Two focal independent variables, acute alcohol consumption and alcohol outlet availability, were measured. Conditional logistic regression was adjusted for confounding variables. Gun suicide risk to individuals in areas of high alcohol outlet availability was less than the gun suicide risk they incurred from acute alcohol consumption, especially to excess. This corroborates prior work but also uncovers new information about the relationships between acute alcohol consumption, alcohol outlets, and gun suicide. Study limitations and implications are discussed. PMID:21929327

  15. Acute alcohol consumption, alcohol outlets, and gun suicide.

    PubMed

    Branas, Charles C; Richmond, Therese S; Ten Have, Thomas R; Wiebe, Douglas J

    2011-01-01

    A case-control study of 149 intentionally self-inflicted gun injury cases (including completed gun suicides) and 302 population-based controls was conducted from 2003 to 2006 in a major US city. Two focal independent variables, acute alcohol consumption and alcohol outlet availability, were measured. Conditional logistic regression was adjusted for confounding variables. Gun suicide risk to individuals in areas of high alcohol outlet availability was less than the gun suicide risk they incurred from acute alcohol consumption, especially to excess. This corroborates prior work but also uncovers new information about the relationships between acute alcohol consumption, alcohol outlets, and gun suicide. Study limitations and implications are discussed.

  16. 7 CFR 993.108 - Non-human consumption outlet.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Non-human consumption outlet. 993.108 Section 993.108... CALIFORNIA Administrative Rules and Regulations Definitions § 993.108 Non-human consumption outlet. Non-human... feed, or other product for non-human use, who has established, to the satisfaction of the committee...

  17. 7 CFR 993.108 - Non-human consumption outlet.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 8 2011-01-01 2011-01-01 false Non-human consumption outlet. 993.108 Section 993.108... CALIFORNIA Administrative Rules and Regulations Definitions § 993.108 Non-human consumption outlet. Non-human... feed, or other product for non-human use, who has established, to the satisfaction of the committee...

  18. 7 CFR 993.108 - Non-human consumption outlet.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 8 2013-01-01 2013-01-01 false Non-human consumption outlet. 993.108 Section 993.108... CALIFORNIA Administrative Rules and Regulations Definitions § 993.108 Non-human consumption outlet. Non-human... feed, or other product for non-human use, who has established, to the satisfaction of the committee...

  19. 39. OUTLET WORKS: CONTROL HOUSE STRUCTURAL DETAILS. Sheet 33, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    39. OUTLET WORKS: CONTROL HOUSE - STRUCTURAL DETAILS. Sheet 33, August 20, 1938. File no. SA 121/72. - Prado Dam, Outlet Works, Santa Ana River near junction of State Highways 71 & 91, Corona, Riverside County, CA

  20. 34. OUTLET WORKS: GATES ELEVATIONS AND SECTION. Sheet 43, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    34. OUTLET WORKS: GATES - ELEVATIONS AND SECTION. Sheet 43, August 20, 1938. File no. SA 121/89(?). - Prado Dam, Outlet Works, Santa Ana River near junction of State Highways 71 & 91, Corona, Riverside County, CA

  1. 45. OUTLET WORKS: SERVICE BRIDGE BEARING DETAILS. Sheet 39, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    45. OUTLET WORKS: SERVICE BRIDGE - BEARING DETAILS. Sheet 39, August 20, 1938. File no. SA 121/78. - Prado Dam, Outlet Works, Santa Ana River near junction of State Highways 71 & 91, Corona, Riverside County, CA

  2. 44. OUTLET WORKS: SERVICE BRIDGE GIRDER DETAILS. Sheet 38, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    44. OUTLET WORKS: SERVICE BRIDGE - GIRDER DETAILS. Sheet 38, August 20, 1938. File no. SA 121/77. - Prado Dam, Outlet Works, Santa Ana River near junction of State Highways 71 & 91, Corona, Riverside County, CA

  3. 31. OUTLET WORKS: INTAKE PLAN AND SECTIONS. Sheet 21, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    31. OUTLET WORKS: INTAKE - PLAN AND SECTIONS. Sheet 21, August 20, 1938. File no. SA 121/60. - Prado Dam, Outlet Works, Santa Ana River near junction of State Highways 71 & 91, Corona, Riverside County, CA

  4. Prevention of Freezing and other Cold Weather Problems at Wastewater Treatment Facilities.

    DTIC Science & Technology

    1985-07-01

    an Archimedes screw conveyor is used to lift grit out of the sub- merged hopper. Initially, the conveyor was exposed and froze completely every...particular facility includes two primary clarifiers (in paral- lel), Archimedes screw pumps to lift wastewater to the top of the trickling filter...gal. of oil each and it takes much time to drain these gear boxes. At the headworks, an Archimedes screw is used to [if t the grit out of a submerged

  5. 38. OUTLET WORKS: CONTROL HOUSE PLAN AND ELEVATIONS. Sheet ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    38. OUTLET WORKS: CONTROL HOUSE - PLAN AND ELEVATIONS. Sheet 32, August 20, 1938. File no. SA 121/71. - Prado Dam, Outlet Works, Santa Ana River near junction of State Highways 71 & 91, Corona, Riverside County, CA

  6. 43. OUTLET WORKS: SERVICE BRIDGE PLAN AND ELEVATION. Sheet ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    43. OUTLET WORKS: SERVICE BRIDGE - PLAN AND ELEVATION. Sheet 37, August 20, 1938. File no. SA 121/76. - Prado Dam, Outlet Works, Santa Ana River near junction of State Highways 71 & 91, Corona, Riverside County, CA

  7. 30. CONSTRUCTION LAYOUT DETAILS OF OUTLET WORKS AND SPILLWAY. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    30. CONSTRUCTION LAYOUT - DETAILS OF OUTLET WORKS AND SPILLWAY. Sheet C-10, September, 1938. File no. SA 343/1. - Prado Dam, Outlet Works, Santa Ana River near junction of State Highways 71 & 91, Corona, Riverside County, CA

  8. Melting beneath Greenland outlet glaciers and ice streams

    NASA Astrophysics Data System (ADS)

    Alexander, David; Perrette, Mahé; Beckmann, Johanna

    2015-04-01

    Basal melting of fast-flowing Greenland outlet glaciers and ice streams due to frictional heating at the ice-bed interface contributes significantly to total glacier mass balance and subglacial meltwater flux, yet modelling this basal melt process in Greenland has received minimal research attention. A one-dimensional dynamic ice-flow model is calibrated to the present day longitudinal profiles of 10 major Greenland outlet glaciers and ice streams (including the Jakobshavn Isbrae, Petermann Glacier and Helheim Glacier) and is validated against published ice flow and surface elevation measurements. Along each longitudinal profile, basal melt is calculated as a function of ice flow velocity and basal shear stress. The basal shear stress is dependent on the effective pressure (difference between ice overburden pressure and water pressure), basal roughness and a sliding parametrization. Model output indicates that where outlet glaciers and ice streams terminate into the ocean with either a small floating ice tongue or no floating tongue whatsoever, the proportion of basal melt to total melt (surface, basal and submarine melt) is 5-10% (e.g. Jakobshavn Isbrae; Daugaard-Jensen Glacier). This proportion is, however, negligible where larger ice tongues lose mass mostly by submarine melt (~1%; e.g. Nioghalvfjerdsfjorden Glacier). Modelled basal melt is highest immediately upvalley of the grounding line, with contributions typically up to 20-40% of the total melt for slippery beds and up to 30-70% for resistant beds. Additionally, modelled grounding line and calving front migration inland for all outlet glaciers and ice streams of hundreds of metres to several kilometres occurs. Including basal melt due to frictional heating in outlet glacier and ice stream models is important for more accurately modelling mass balance and subglacial meltwater flux, and therefore, more accurately modelling outlet glacier and ice stream dynamics and responses to future climate change.

  9. Perceived ejaculatory latency and pleasure in different outlets.

    PubMed

    Corty, Eric W

    2008-11-01

    Ejaculatory latencies have been studied in coitus and with masturbation, but not with oral or manual stimulation by a partner. The present study extended research on ejaculatory latency to these outlets, and investigated the effect of perceived pleasure on self-reported ejaculatory latency. A convenience sample of male college students, not selected for sexual dysfunction, completed questionnaires assessing the outcome measures. Self-report measures of latency to ejaculation in, and perceived pleasure associated with, four different outlets (vaginal intercourse, oral intercourse, manual stimulation by a partner, and masturbation). Ejaculatory latencies in partnered activities were predictive of each other. Masturbatory latencies were predictive of coital latencies but not oral or manual stimulation latencies; all the partnered activities were predictive of each other. There was no difference in time to ejaculation among any of the partnered outlets, although ejaculation occurred more quickly with masturbation than with coitus or manual stimulation. In terms of pleasure associated with the outlets, vaginal and oral intercourse were perceived as equally pleasurable, and both were rated as more pleasurable than manual stimulation or masturbation, which did not differ from each other. These results suggest that rapidity of ejaculation is consistent across outlets for the partnered sexual activities, and that there is little unique-in terms of ejaculatory latency--about vaginal intercourse compared with oral or manual stimulation by a partner. Masturbation, however, does differ from the partnered activities. Although the average correlation, for individuals, between latency and pleasure for the different outlets is near zero, there are subgroups of men who have (i) a negative relation, (ii) a positive relation, or (iii) no relation. Results show that men, for whom greater pleasure is associated with shorter latency, are more likely to be dissatisfied with their

  10. 42. OUTLET WORKS: CONTROL TOWER ELEVATIONS AND SECTIONS NO. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    42. OUTLET WORKS: CONTROL TOWER - ELEVATIONS AND SECTIONS NO. 2. Sheet 36, August 20, 1938. File no. SA 121/79. - Prado Dam, Outlet Works, Santa Ana River near junction of State Highways 71 & 91, Corona, Riverside County, CA

  11. 41. OUTLET WORKS: CONTROL TOWER ELEVATIONS AND SECTIONS NO. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    41. OUTLET WORKS: CONTROL TOWER - ELEVATIONS AND SECTIONS NO. 1. Sheet 35, August 20, 1938. File no. SA 121/74. - Prado Dam, Outlet Works, Santa Ana River near junction of State Highways 71 & 91, Corona, Riverside County, CA

  12. High sensitivity of tidewater outlet glacier dynamics to shape

    NASA Astrophysics Data System (ADS)

    Enderlin, E. M.; Howat, I. M.; Vieli, A.

    2013-02-01

    Variability in tidewater outlet glacier behavior under similar external forcing has been attributed to differences in outlet shape (i.e. bed elevation and width), but this dependence has not been investigated in detail. Here we use a numerical ice flow model to show that the dynamics of tidewater outlet glaciers under external forcing are highly sensitive to width and bed topography. Our sensitivity tests indicate that for glaciers with similar discharge, the trunks of wider glaciers and those grounded over deeper basal depressions tend to be closer to flotation, so that less dynamically induced thinning results in rapid, unstable retreat following a perturbation. The lag time between the onset of the perturbation and unstable retreat varies with outlet shape, which may help explain intra-regional variability in tidewater outlet glacier behavior. Further, because the perturbation response is dependent on the thickness relative to flotation, varying the bed topography within the range of observational uncertainty can result in either stable or unstable retreat due to the same perturbation. Thus, extreme care must be taken when interpreting the future behavior of actual glacier systems using numerical ice flow models that are not accompanied by comprehensive sensitivity analyses.

  13. High sensitivity of tidewater outlet glacier dynamics to shape

    NASA Astrophysics Data System (ADS)

    Enderlin, E. M.; Howat, I. M.; Vieli, A.

    2013-06-01

    Variability in tidewater outlet glacier behavior under similar external forcing has been attributed to differences in outlet shape (i.e., bed elevation and width), but this dependence has not been investigated in detail. Here we use a numerical ice flow model to show that the dynamics of tidewater outlet glaciers under external forcing are highly sensitive to width and bed topography. Our sensitivity tests indicate that for glaciers with similar discharge, the trunks of wider glaciers and those grounded over deeper basal depressions tend to be closer to flotation, so that less dynamically induced thinning results in rapid, unstable retreat following a perturbation. The lag time between the onset of the perturbation and unstable retreat varies with outlet shape, which may help explain intra-regional variability in tidewater outlet glacier behavior. Further, because the perturbation response is dependent on the thickness relative to flotation, varying the bed topography within the range of observational uncertainty can result in either stable or unstable retreat due to the same perturbation. Thus, extreme care must be taken when interpreting the future behavior of actual glacier systems using numerical ice flow models that are not accompanied by comprehensive sensitivity analyses.

  14. 37. OUTLET WORKS: CONTROL WORKS ELEVATIONS AND INDEX TO ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    37. OUTLET WORKS: CONTROL WORKS - ELEVATIONS AND INDEX TO REFERENCE DRAWINGS. Sheet 31, August 20, 1938. File no. SA 121/70. - Prado Dam, Outlet Works, Santa Ana River near junction of State Highways 71 & 91, Corona, Riverside County, CA

  15. Increased Levels of Multiresistant Bacteria and Resistance Genes after Wastewater Treatment and Their Dissemination into Lake Geneva, Switzerland

    PubMed Central

    Czekalski, Nadine; Berthold, Tom; Caucci, Serena; Egli, Andrea; Bürgmann, Helmut

    2012-01-01

    At present, very little is known about the fate and persistence of multiresistant bacteria (MRB) and their resistance genes in natural aquatic environments. Treated, but partly also untreated sewage of the city of Lausanne, Switzerland is discharged into Vidy Bay (Lake Geneva) resulting in high levels of contamination in this part of the lake. In the present work we have studied the prevalence of MRB and resistance genes in the wastewater stream of Lausanne. Samples from hospital and municipal raw sewage, treated effluent from Lausanne’s wastewater treatment plant (WTP) as well as lake water and sediment samples obtained close to the WTP outlet pipe and a remote site close to a drinking water pump were evaluated for the prevalence of MRB. Selected isolates were identified (16S rRNA gene fragment sequencing) and characterized with regards to further resistances, resistance genes, and plasmids. Mostly, studies investigating this issue have relied on cultivation-based approaches. However, the limitations of these tools are well known, in particular for environmental microbial communities, and cultivation-independent molecular tools should be applied in parallel in order to take non-culturable organisms into account. Here we directly quantified the sulfonamide resistance genes sul1 and sul2 from environmental DNA extracts using TaqMan real-time quantitative PCR. Hospital sewage contained the highest load of MRB and antibiotic resistance genes (ARGs). Wastewater treatment reduced the total bacterial load up to 78% but evidence for selection of extremely multiresistant strains and accumulation of resistance genes was observed. Our data clearly indicated pollution of sediments with ARGs in the vicinity of the WTP outlet. The potential of lakes as reservoirs of MRB and potential risks are discussed. PMID:22461783

  16. Local tobacco policy and tobacco outlet density: associations with youth smoking.

    PubMed

    Lipperman-Kreda, Sharon; Grube, Joel W; Friend, Karen B

    2012-06-01

    This study investigates the associations between local tobacco policy, tobacco outlet density, and youth smoking. A primary focus is on whether local tobacco policy moderates the relation between outlet density and youth smoking. In all, 1,491 youth (51.9% male, mean age = 14.7 years, standard deviation = 1.05) in 50 midsized California cities were surveyed through a computer-assisted telephone interview. Measures of local clean air policy and youth access policy were created based on a review of tobacco policies in these cities. Outlet density was calculated as the number of retail tobacco outlets per 10,000 persons, and city characteristics were obtained from 2000 U.S. Census data. Using multilevel regression analyses and controlling for city characteristics, tobacco outlet density was positively associated with youth smoking. No significant main effects were found for the two tobacco policy types on any of the smoking outcomes after controlling for interactions and covariates. However, statistically significant interactions were found between local clean air policy and tobacco outlet density for ever smoked and past 12-month cigarette smoking. Comparisons of simple slopes indicated that the positive associations between tobacco outlet density and youth smoking behaviors were stronger at the lowest level of local clean air policy compared with the moderate and high levels. Our results suggest that tobacco outlet density is related to youth smoking. In addition, local clean air policy may act as a moderator of relationship between tobacco outlet density and youth smoking, such that density is less important at moderate and high levels of this tobacco policy. Copyright © 2012 Society for Adolescent Health and Medicine. Published by Elsevier Inc. All rights reserved.

  17. A self-sustaining high-strength wastewater treatment system using solar-bio-hybrid power generation.

    PubMed

    Bustamante, Mauricio; Liao, Wei

    2017-06-01

    This study focuses on system analysis of a self-sustaining high-strength wastewater treatment concept combining solar technologies, anaerobic digestion, and aerobic treatment to reclaim water. A solar bio-hybrid power generation unit was adopted to power the wastewater treatment. Concentrated solar power (CSP) and photovoltaics (PV) were combined with biogas energy from anaerobic digestion. Biogas is also used to store the extra energy generated by the hybrid power unit and ensure stable and continuous wastewater treatment. It was determined from the energy balance analysis that the PV-bio hybrid power unit is the preferred energy unit to realize the self-sustaining high-strength wastewater treatment. With short-term solar energy storage, the PV-bio-hybrid power unit in Phoenix, AZ requires solar collection area (4032m 2 ) and biogas storage (35m 3 ), while the same unit in Lansing, MI needs bigger solar collection area and biogas storage (5821m 2 and 105m 3 , respectively) due to the cold climate. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. The Patient Burden of Bladder Outlet Obstruction after Prostate Cancer Treatment.

    PubMed

    Liberman, Daniel; Jarosek, Stephanie; Virnig, Beth A; Chu, Haitao; Elliott, Sean P

    2016-05-01

    Bladder outlet obstruction after prostate cancer therapy imposes a significant burden on health and quality of life in men. Our objective was to describe the burden of bladder outlet obstruction after prostate cancer therapy by detailing the type of procedures performed and how often those procedures were repeated in men with recurrent bladder outlet obstruction. Using SEER (Surveillance, Epidemiology and End Results)-Medicare linked data from 1992 to 2007 with followup through 2009 we identified 12,676 men who underwent at least 1 bladder outlet obstruction procedure after prostate cancer therapy, including external beam radiotherapy in 3,994, brachytherapy in 1,485, brachytherapy plus external beam radiotherapy in 1,847, radical prostatectomy in 4,736, radical prostatectomy plus external beam radiotherapy in 369 and cryotherapy in 245. Histogram, incidence rates and Cox proportional hazards models with repeat events analysis were done to describe the burden of repeat bladder outlet obstruction treatments stratified by prostate cancer therapy type. We describe the type of bladder outlet obstruction surgery grouped by level of invasiveness. At a median followup of 8.8 years 44.6% of men underwent 2 or more bladder outlet obstruction procedures. Compared to men who underwent radical prostatectomy those treated with brachytherapy and brachytherapy plus external beam radiotherapy were at increased adjusted risk for repeat bladder outlet obstruction treatment (HR 1.2 and 1.32, respectively, each p <0.05). After stricture incision the men treated with radical prostatectomy or radical prostatectomy plus external beam radiotherapy were most likely to undergo dilation at a rate of 34.7% to 35.0%. Stricture resection/ablation was more common after brachytherapy, external beam radiotherapy or brachytherapy plus external beam radiotherapy at a rate of 28.9% to 41.2%. Almost half of the men with bladder outlet obstruction after prostate cancer therapy undergo more than 1

  19. A novel sequential process for remediating rare-earth wastewater.

    PubMed

    Cui, Mingcan; Jang, Min; Kang, Kyounglim; Kim, Dukmin; Snyder, Shane A; Khim, Jeehyeong

    2016-02-01

    A novel and economic sequential process consisting of precipitation, adsorption, and oxidation was developed to remediate actual rare-earth (RE) wastewater containing various toxic pollutants, including radioactive species. In the precipitation step, porous air stones (PAS) containing waste oyster shell (WOS), PASWOS, was prepared and used to precipitate most heavy metals with >97% removal efficiencies. The SEM-EDS analysis revealed that PAS plays a key role in preventing the surface coating of precipitants on the surface of WOS and in releasing the dissolved species of WOS successively. For the adsorption step, a polyurethane (PU) impregnated by coal mine drainage sludge (CMDS), PUCMDS, was synthesized and applied to deplete fluoride (F), arsenic (As), uranium (U), and thorium (Th) that remained after precipitation. The continuous-mode sequential process using PAS(WOS), PU(CMDS), and ozone (O3) had 99.9-100% removal efficiencies of heavy metals, 99.3-99.9% of F and As, 95.8-99.4% of U and Th, and 92.4% of COD(Cr) for 100 days. The sequential process can treat RE wastewater economically and effectively without stirred-tank reactors, pH controller, continuous injection of chemicals, and significant sludge generation, as well as the quality of the outlet met the EPA recommended limits. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. [FTIR and 13C NMR Analysis of Dissolved Organic Matter (DOM) in the Treatment Process of Tannery Wastewater].

    PubMed

    Fan, Chun-hui; Zhang, Ying-chao; Tang, Ze-heng; Wang, Jia-hong

    2015-05-01

    Nowadays, the wastewater quantity discharged yearly from tannery industry is around 0. 2 billion t in China. The contaminants of tannery wastewater include macromolecular organic matters, such as grease, fur scraps and collagen, and the alkaline wastewater appears to be of high content of salt and COD. The quality of tannery wastewater is monitored strictly among all kinds of industry wastewater. In the treatment process of tannery wastewater, the quality of inlet and outlet water is generally analyzed. In fact, the transformation behavior of contaminants should be additionally checked to optimize the treatment conditions. Dissolved organic matter (DOM) is commonly existed in water-bodies and helpful to understand the physicochemical characteristics, while the related work should be further studied on tannery wastewater. The approaches of elemental analysis, thermal gravimetric analysis (TG), Fourier infrared spectroscopy (FTIR) and 13C nuclear magnetic resonance (13C NMR) were used to reveal the characteristics of DOM in the treatment process of tannery wastewater. The results showed the carbon content of DOM samples increased gradually, atomic ratios of H/C increased firstly and then decreased, indicating the organic matters were decomposed into chain structures firstly, finally forming the component hard to degraded. The pyrolysis process of DOM mainly proceeded in the regions of 110~530 °C (aliphatic compound, protein, etc. ) and 530~800 °C (aromatic ring, single bond of C-C, etc. ). The functional groups of DOM included -OH, -NH2, C=O and so on, and the aromatic substances were detected, shown from FTIR figures, in the later period of the reaction, caused by the metabolism effect of micro-organism. The content of alkoxy-C increased to the maximum in the second biochemical pond, and the minimum content of aromatic-C appeared in the second biochemical pond, suggesting the transformation behavior of carbon functional groups. The investigation on DOM in tannery

  1. 12 CFR 7.1014 - Sale of money orders at nonbanking outlets.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 12 Banks and Banking 1 2011-01-01 2011-01-01 false Sale of money orders at nonbanking outlets. 7... ACTIVITIES AND OPERATIONS Bank Powers § 7.1014 Sale of money orders at nonbanking outlets. A national bank may designate bonded agents to sell the bank's money orders at nonbanking outlets. The responsibility...

  2. 12 CFR 7.1014 - Sale of money orders at nonbanking outlets.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 12 Banks and Banking 1 2012-01-01 2012-01-01 false Sale of money orders at nonbanking outlets. 7... ACTIVITIES AND OPERATIONS Bank Powers § 7.1014 Sale of money orders at nonbanking outlets. A national bank may designate bonded agents to sell the bank's money orders at nonbanking outlets. The responsibility...

  3. 12 CFR 7.1014 - Sale of money orders at nonbanking outlets.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 12 Banks and Banking 1 2014-01-01 2014-01-01 false Sale of money orders at nonbanking outlets. 7... ACTIVITIES AND OPERATIONS Bank Powers § 7.1014 Sale of money orders at nonbanking outlets. A national bank may designate bonded agents to sell the bank's money orders at nonbanking outlets. The responsibility...

  4. 12 CFR 7.1014 - Sale of money orders at nonbanking outlets.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 12 Banks and Banking 1 2013-01-01 2013-01-01 false Sale of money orders at nonbanking outlets. 7... ACTIVITIES AND OPERATIONS Bank Powers § 7.1014 Sale of money orders at nonbanking outlets. A national bank may designate bonded agents to sell the bank's money orders at nonbanking outlets. The responsibility...

  5. 12 CFR 7.1014 - Sale of money orders at nonbanking outlets.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 12 Banks and Banking 1 2010-01-01 2010-01-01 false Sale of money orders at nonbanking outlets. 7... ACTIVITIES AND OPERATIONS Bank Powers § 7.1014 Sale of money orders at nonbanking outlets. A national bank may designate bonded agents to sell the bank's money orders at nonbanking outlets. The responsibility...

  6. A longitudinal analysis of alcohol outlet density and domestic violence.

    PubMed

    Livingston, Michael

    2011-05-01

    A small number of studies have identified a positive relationship between alcohol outlet density and domestic violence. These studies have all been based on cross-sectional data and have been limited to the assessment of ecological correlations between outlet density and domestic violence rates. This study provides the first longitudinal examination of this relationship. Cross-sectional time-series using aggregated data from small areas. The relationships between alcohol outlet density and domestic violence were assessed over time using a fixed-effects model. Controls for the spatial autocorrelation of the data were included in the model. The study uses data for 186 postcodes from within the metropolitan area of Melbourne, Australia for the years 1996 to 2005. Alcohol outlet density measures for three different types of outlets (hotel/pub, packaged liquor, on-premise) were derived from liquor licensing records and domestic violence rates were calculated from police-recorded crime data, based on the victim's postcode. Alcohol outlet density was associated significantly with rates of domestic violence, over time. All three licence categories were positively associated with domestic violence rates, with small effects for general (pub) and on-premise licences and a large effect for packaged liquor licences. In Melbourne, the density of liquor licences is positively associated with rates of domestic violence over time. The effects were particularly large for packaged liquor outlets, suggesting a need for licensing policies that pay more attention to o off-premise alcohol availability. © 2011 The Authors, Addiction © 2011 Society for the Study of Addiction.

  7. 12. Photographic copy of copy of Twin Lakes Outlet Works ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    12. Photographic copy of copy of Twin Lakes Outlet Works construction drawing dated January 15, 1951. Drawn by W.A. Doe for the Twin Lakes Reservoir and Canal Co. (copy in possession of Bureau of Reclamation, location of original unknown) 'AS CONSTRUCTED' PLANS OF 1949-50, REHABILITATION OF TWIN LAKES RESERVOIR OUTLET WORKS, DETAILS OF DISCHARGE BASIN. - Twin Lakes Dam & Outlet Works, Beneath Twin Lakes Reservoir, T11S, R80W, S22, Twin Lakes, Lake County, CO

  8. Modeling the Effects of Onsite Wastewater Treatment Systems on Nitrate Loads Using SWAT in an Urban Watershed of Metropolitan Atlanta.

    PubMed

    Hoghooghi, Nahal; Radcliffe, David E; Habteselassie, Mussie Y; Jeong, Jaehak

    2017-05-01

    Onsite wastewater treatment systems (OWTSs) can be a source of nitrogen (N) pollution in both surface and ground waters. In metropolitan Atlanta, GA, >26% of homes are on OWTSs. In a previous article, we used the Soil Water Assessment Tool to model the effect of OWTSs on stream flow in the Big Haynes Creek Watershed in metropolitan Atlanta. The objective of this study was to estimate the effect of OWTSs, including failing systems, on nitrate as N (NO-N) load in the same watershed. Big Haynes Creek has a drainage area of 44 km with mainly urban land use (67%), and most of the homes use OWTSs. A USGS gauge station where stream flow was measured daily and NO-N concentrations were measured monthly was used as the outlet. The model was simulated for 12 yr. Overall, the model showed satisfactory daily stream flow and NO-N loads with Nash-Sutcliffe coefficients of 0.62 and 0.58 for the calibration period and 0.67 and 0.33 for the validation period at the outlet of the Big Haynes Watershed. Onsite wastewater treatment systems caused an average increase in NO-N load of 23% at the watershed scale and 29% at the outlet of a subbasin with the highest density of OWTSs. Failing OWTSs were estimated to be 1% of the total systems and did not have a large impact on stream flow or NO-N load. The NO-N load was 74% of the total N load in the watershed, indicating the important effect of OWTSs on stream loads in this urban watershed. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  9. Neighbourhood fast food outlets and obesity in children and adults: the CLAN Study.

    PubMed

    Crawford, David A; Timperio, Anna F; Salmon, Jo A; Baur, Louise; Giles-Corti, Billie; Roberts, Rebecca J; Jackson, Michelle L; Andrianopoulos, Nick; Ball, Kylie

    2008-01-01

    We examined associations between density of and proximity to fast food outlets and body weight in a sample of children (137 aged 8-9 years and 243 aged 13-15 years) and their parents (322 fathers and 362 mothers). Children's measured and parents' self-reported heights and weights were used to calculate body mass index (BMI). Locations of major fast food outlets were geocoded. Bivariate linear regression analyses examined associations between the presence of any fast food outlet within a 2 km buffer around participants' homes, fast food outlet density within the 2 km buffer, and distance to the nearest outlet and BMI. Each independent variable was also entered into separate bivariate logistic regression analyses to predict the odds of being overweight or obese. Among older children, those with at least one outlet within 2 km had lower BMI z-scores. The further that fathers lived from an outlet, the higher their BMI. Among 13-15-year-old girls and their fathers, the likelihood of overweight/obesity was reduced by 80% and 50%, respectively, if they had at least one fast food outlet within 2 km of their home. Among older girls, the likelihood of being overweight/obese was reduced by 14% with each additional outlet within 2 km. Fathers' odds of being overweight/obese increased by 13% for each additional kilometre to the nearest outlet. While consumption of fast food has been shown to be associated with obesity, this study provides little support for the concept that exposure to fast food outlets in the local neighbourhood increases risk of obesity.

  10. Association Between Alcohol Outlets and HIV Prevalence in U.S. Counties.

    PubMed

    Rossheim, Matthew E; Thombs, Dennis L; Suzuki, Sumihiro

    2016-11-01

    The current study examines associations between on- and off-premise alcohol retail outlets and HIV prevalence in counties across the United States during a 3-year period. Health department and U.S. Census Bureau surveillance data were analyzed from 1,523 counties in 47 states, representing more than 86% of the U.S. population. Multilevel Poisson regression models were used to examine the association between the number of on- and off-premise alcohol outlets in a county and HIV prevalence in the same county, adjusting for the between-year correlation of HIV prevalence within each county. When we adjusted for potential confounders, number of on-premise alcohol outlets within a county was positively associated with HIV prevalence, whereas off-premise alcohol outlets were negatively associated with HIV prevalence. The relations observed in this study are consistent with the niche theory of assortative drinking, which maintains that drinkers who are prone to risk taking may be attracted to alcohol outlets where they can expand their social networks to include similarly high-risk individuals who engage in both heavy drinking and sexual risk taking. This is the largest study conducted to date to examine the association between alcohol retail outlet types and HIV prevalence. Natural experiments are needed to examine specific policy changes that reduce outlet density and its association with HIV incidence.

  11. 23. DOWNSTREAM VIEW OF COMPLETED OUTLET CONTROL STRUCTURE.... Volume XIX, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    23. DOWNSTREAM VIEW OF COMPLETED OUTLET CONTROL STRUCTURE.... Volume XIX, No. 8, April 12, 1940. - Prado Dam, Outlet Works, Santa Ana River near junction of State Highways 71 & 91, Corona, Riverside County, CA

  12. Alcohol outlet density and violence: A geographically weighted regression approach.

    PubMed

    Cameron, Michael P; Cochrane, William; Gordon, Craig; Livingston, Michael

    2016-05-01

    We investigate the relationship between outlet density (of different types) and violence (as measured by police activity) across the North Island of New Zealand, specifically looking at whether the relationships vary spatially. We use New Zealand data at the census area unit (approximately suburb) level, on police-attended violent incidents and outlet density (by type of outlet), controlling for population density and local social deprivation. We employed geographically weighted regression to obtain both global average and locally specific estimates of the relationships between alcohol outlet density and violence. We find that bar and night club density, and licensed club density (e.g. sports clubs) have statistically significant and positive relationships with violence, with an additional bar or night club is associated with nearly 5.3 additional violent events per year, and an additional licensed club associated with 0.8 additional violent events per year. These relationships do not show significant spatial variation. In contrast, the effects of off-licence density and restaurant/café density do exhibit significant spatial variation. However, the non-varying effects of bar and night club density are larger than the locally specific effects of other outlet types. The relationships between outlet density and violence vary significantly across space for off-licences and restaurants/cafés. These results suggest that in order to minimise alcohol-related harms, such as violence, locally specific policy interventions are likely to be necessary. [Cameron MP, Cochrane W, Gordon C, Livingston M. Alcohol outlet density and violence: A geographically weighted regression approach. Drug Alcohol Rev 2016;35:280-288]. © 2015 Australasian Professional Society on Alcohol and other Drugs.

  13. 11. Photographic copy of copy of Twin Lakes Outlet Works ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    11. Photographic copy of copy of Twin Lakes Outlet Works construction drawing dated January 15, 1951. Drawn by W.A. Doe for the Twin Lakes Reservoir and Canal Co. (copy in possession of Bureau of Reclamation, location of original unknown) 'AS CONSTRUCTED' PLANS OF 1949-1950, REHABILITATION OF TWIN LAKES RESERVOIR OUTLET WORKS, DETAILS OF UPSTREAM WING WALLS. - Twin Lakes Dam & Outlet Works, Beneath Twin Lakes Reservoir, T11S, R80W, S22, Twin Lakes, Lake County, CO

  14. 26. UPSTREAM VIEW OF DISCHARGE END OF OUTLET STRUCTURE.... Volume ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    26. UPSTREAM VIEW OF DISCHARGE END OF OUTLET STRUCTURE.... Volume XVI, No. 17, September 29, 1939. - Prado Dam, Outlet Works, Santa Ana River near junction of State Highways 71 & 91, Corona, Riverside County, CA

  15. 35. OUTLET WORKS: GATE HOIST ASSEMBLY. Sheet 44, August 20, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    35. OUTLET WORKS: GATE HOIST ASSEMBLY. Sheet 44, August 20, 1938. File no. SA 121/84(?). - Prado Dam, Outlet Works, Santa Ana River near junction of State Highways 71 & 91, Corona, Riverside County, CA

  16. Socioeconomic area disparities in tobacco retail outlet density: a Western Australian analysis.

    PubMed

    Wood, Lisa J; Pereira, Gavin; Middleton, Nick; Foster, Sarah

    2013-05-20

    To examine the association between tobacco outlet density and area socioeconomic status (SES) in Western Australia. Ecological cross-sectional study investigating the relationship between the area SES of, and the density of tobacco retail outlets in, WA suburbs and towns for the Perth metropolitan area, and at the regional and state level. SES was determined using the 2006 Australian Bureau of Statistics Index of Relative Socioeconomic Advantage and Disadvantage (IRSAD) and classified into quartiles (very low, low, high and very high); tobacco outlet data were sourced from the WA Department of Health register of retailers licensed to sell tobacco at May 2011. Tobacco outlet density rate (per 10 000 residents). In WA overall, suburbs and towns with a very low IRSAD had more than four times the number of tobacco outlets compared with those with a very high IRSAD (P> < 0.001). This trend was similar when analyses were restricted to the Perth metropolitan area and to regional areas. Suburbs and towns in regional WA with a very low IRSAD had more than five times the number of tobacco outlets than those with a very high IRSAD (P> < 0.001). This study provides the first Australian evidence of a strong relationship between area SES and tobacco outlet density. Findings are consistent with a number of United States studies that report higher tobacco outlet densities in lower SES or minority neighbourhoods. The results underscore the importance of policy approaches to limit the number of tobacco retail licences granted, and to reduce the geographic density of outlets in more disadvantaged suburbs and towns.

  17. The geography of violence, alcohol outlets, and drug arrests in Boston.

    PubMed

    Lipton, Robert; Yang, Xiaowen; Braga, Anthony A; Goldstick, Jason; Newton, Manya; Rura, Melissa

    2013-04-01

    We examined the relationship between alcohol outlets, drug markets (approximated by arrests for possession and trafficking), and violence in Boston, Massachusetts, in 2006. We analyzed geographic and environmental versus individual factors related to violence and identified areas high in violent crime. We used data from the Boston Police Department, US Census, and Massachusetts State Alcohol Beverage Control Commission. Spatial modeling was employed at the block group level, and violent crime, alcohol outlets, and drug markets were mapped. Relative to other block groups, block groups in the highest decile of violent crime (n = 55) were found to be poorer (e.g., lower incomes, higher percentages of vacant homes), and they had greater numbers of alcohol outlets and higher drug arrest rates. Alcohol outlets and drug possession and trafficking arrests were predictive of violent crime. Also, spatial effects resulting from neighboring block groups were related to violent crime. Both alcohol outlet density and type were associated with violent crime in a differentiated and complex way. With drug possession and trafficking arrests as a proxy for drug markets, spatial relationships between alcohol outlets and violence were found in addition to typical sociodemographic predictors.

  18. The Geography of Violence, Alcohol Outlets, and Drug Arrests in Boston

    PubMed Central

    Yang, Xiaowen; A. Braga, Anthony; Goldstick, Jason; Newton, Manya; Rura, Melissa

    2013-01-01

    Objectives. We examined the relationship between alcohol outlets, drug markets (approximated by arrests for possession and trafficking), and violence in Boston, Massachusetts, in 2006. We analyzed geographic and environmental versus individual factors related to violence and identified areas high in violent crime. Methods. We used data from the Boston Police Department, US Census, and Massachusetts State Alcohol Beverage Control Commission. Spatial modeling was employed at the block group level, and violent crime, alcohol outlets, and drug markets were mapped. Results. Relative to other block groups, block groups in the highest decile of violent crime (n = 55) were found to be poorer (e.g., lower incomes, higher percentages of vacant homes), and they had greater numbers of alcohol outlets and higher drug arrest rates. Alcohol outlets and drug possession and trafficking arrests were predictive of violent crime. Also, spatial effects resulting from neighboring block groups were related to violent crime. Both alcohol outlet density and type were associated with violent crime in a differentiated and complex way. Conclusions. With drug possession and trafficking arrests as a proxy for drug markets, spatial relationships between alcohol outlets and violence were found in addition to typical sociodemographic predictors. PMID:23409885

  19. Alcohol outlet business hours and violent crime in New York state.

    PubMed

    Schofield, Timothy P; Denson, Thomas F

    2013-01-01

    Alcohol-related harm places a significant strain on victims, perpetrators and society. The present research reports on how licensed alcohol outlet business hours may influence the reported incidence of interpersonal violence and the associated burden of disease. We examined the relationship between alcohol outlet business hours and violent crime in 2009 in New York State (excluding New York City). Regression analyses modeled the burden of disease for the violence associated with outlet business hours. Every 1 h increase in weekly outlet business hours was associated with a greater reported incidence of violent crimes generally, more reported aggravated assaults and more reported non-gun violence. The estimated cost from having licensed premises open after 1 a.m. was $194 million in 2009. The findings suggest that alcohol outlet business hours affect the incidence of reported violence even in regions that would not be considered to have severe problems with alcohol-fueled violence.

  20. 17. OUTLET STRUCTURE, LOOKING NORTH. NOTE ALSO THE DRAINAGE CHANNEL ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    17. OUTLET STRUCTURE, LOOKING NORTH. NOTE ALSO THE DRAINAGE CHANNEL AND CONCRETE FLUME ALONG WEST EDGE OF EMBANKMENT. - Prado Dam, Outlet Works, Santa Ana River near junction of State Highways 71 & 91, Corona, Riverside County, CA

  1. 46 CFR 34.15-25 - Discharge outlets-T/ALL.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 1 2011-10-01 2011-10-01 false Discharge outlets-T/ALL. 34.15-25 Section 34.15-25 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS FIREFIGHTING EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 34.15-25 Discharge outlets—T/ALL. (a) Discharge outlets shall be of an approved...

  2. 46 CFR 34.17-20 - Discharge outlets-T/ALL.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 1 2011-10-01 2011-10-01 false Discharge outlets-T/ALL. 34.17-20 Section 34.17-20 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS FIREFIGHTING EQUIPMENT Fixed Foam Extinguishing Systems, Details § 34.17-20 Discharge outlets—T/ALL. (a) Discharge outlets shall be of an approved...

  3. 46 CFR 34.17-20 - Discharge outlets-T/ALL.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Discharge outlets-T/ALL. 34.17-20 Section 34.17-20 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS FIREFIGHTING EQUIPMENT Fixed Foam Extinguishing Systems, Details § 34.17-20 Discharge outlets—T/ALL. (a) Discharge outlets shall be of an approved...

  4. 46 CFR 34.15-25 - Discharge outlets-T/ALL.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Discharge outlets-T/ALL. 34.15-25 Section 34.15-25 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS FIREFIGHTING EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 34.15-25 Discharge outlets—T/ALL. (a) Discharge outlets shall be of an approved...

  5. 46 CFR 34.15-25 - Discharge outlets-T/ALL.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 1 2013-10-01 2013-10-01 false Discharge outlets-T/ALL. 34.15-25 Section 34.15-25 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS FIREFIGHTING EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 34.15-25 Discharge outlets—T/ALL. (a) Discharge outlets shall be of an approved...

  6. 46 CFR 34.15-25 - Discharge outlets-T/ALL.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 1 2014-10-01 2014-10-01 false Discharge outlets-T/ALL. 34.15-25 Section 34.15-25 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS FIREFIGHTING EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 34.15-25 Discharge outlets—T/ALL. (a) Discharge outlets shall be of an approved...

  7. 46 CFR 34.15-25 - Discharge outlets-T/ALL.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 1 2012-10-01 2012-10-01 false Discharge outlets-T/ALL. 34.15-25 Section 34.15-25 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS FIREFIGHTING EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 34.15-25 Discharge outlets—T/ALL. (a) Discharge outlets shall be of an approved...

  8. 18. GENERAL VIEW OF THE OUTLET STRUCTURE LOOKING DOWNSTREAM AT ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    18. GENERAL VIEW OF THE OUTLET STRUCTURE LOOKING DOWNSTREAM AT WEST ABUTMENT.... Volume XVI, No. 13, July 26, 1939. - Prado Dam, Outlet Works, Santa Ana River near junction of State Highways 71 & 91, Corona, Riverside County, CA

  9. Tobacco outlet density and attitudes towards smoking among urban adolescent smokers.

    PubMed

    Mennis, Jeremy; Mason, Michael

    2016-01-01

    This study investigates whether residential exposure to tobacco outlets (i.e., convenience stores and other stores selling tobacco) is associated with attitudes towards smoking among a sample of urban, primarily African American, adolescent smokers. Cross-sectional survey data for 197 adolescents were integrated with spatial data on tobacco outlets via subject home addresses. Ordinal regression was employed to test hypotheses that closer proximity to, and higher concentrations of, tobacco outlets are associated with higher measures of intention to continue to smoke in the future, weaker self-efficacy related to stopping smoking, and more accepting social norms related to smoking, while controlling for characteristics of age, gender, family and peer smoking contexts, and level of nicotine dependence. Moderation by age and gender was also investigated. Higher residential tobacco outlet density is significantly associated with a greater intention to smoke in the next 3 months, a lower readiness to stop smoking, and a greater likelihood of accepting a cigarette from a friend. Residential proximity to a tobacco outlet is significantly associated with a greater intention to smoke 5 years on. Evidence of a relationship between exposure to tobacco outlets and social norms related to smoking was not found, nor was there evidence for moderation of these relationships by age or gender. These results suggest that among urban adolescents who currently smoke, higher residential exposure to tobacco outlets is associated with greater predisposition towards future smoking and lower self-evaluation of the ability to stop smoking.

  10. Revealing the link between licensed outlets and violence: counting venues versus measuring alcohol availability.

    PubMed

    Liang, Wenbin; Chikritzhs, Tanya

    2011-09-01

    Associations between alcohol-related harms and numbers of outlets at the neighbourhood level have been demonstrated; however, the degree to which alcohol consumption or sales plays a part in levels of violence is not clear. This has contributed to uncertainty regarding the actual mechanisms by which outlet density may influence levels of violence. This ecological cross-sectional study investigated the effect of outlet numbers and alcohol sales on the risk of assault in Western Australia. For 2000/2001, information on type, number and wholesale alcohol purchases of all licensed outlets in operation, police-reported assault offences, socioeconomic/demographic data were obtained from official sources. Multivariate negative binomial regression was applied to at local government area level in order to assess associations between outlet density, alcohol sales and violence occurring in both licensed and domestic settings. Average alcohol sales volume per off-site outlet was significantly associated with all measures of assault. Numbers of on-site outlets significantly predicted violence with the exception of assaults occurring at residential premises. Alcohol sales from off-site outlets predicted violence occurring at on-site outlets. The link between on-site outlets and violence may be primarily underpinned by negative amenity effects while off-site outlet effects occur via increased availability. Alcohol sales volumes from off-site outlets influence levels of violence, which occur at both licensed and residential settings. The substantial and wide-ranging effects of liquor stores on alcohol-related harms may have been underestimated in the literature and by policy makers. © 2011 Australasian Professional Society on Alcohol and other Drugs.

  11. Validity of secondary retail food outlet data: a systematic review.

    PubMed

    Fleischhacker, Sheila E; Evenson, Kelly R; Sharkey, Joseph; Pitts, Stephanie B Jilcott; Rodriguez, Daniel A

    2013-10-01

    Improving access to healthy foods is a promising strategy to prevent nutrition-related chronic diseases. To characterize retail food environments and identify areas with limited retail access, researchers, government programs, and community advocates have primarily used secondary retail food outlet data sources (e.g., InfoUSA or government food registries). To advance the state of the science on measuring retail food environments, this systematic review examined the evidence for validity reported for secondary retail food outlet data sources for characterizing retail food environments. A literature search was conducted through December 31, 2012, to identify peer-reviewed published literature that compared secondary retail food outlet data sources to primary data sources (i.e., field observations) for accuracy of identifying the type and location of retail food outlets. Data were analyzed in 2013. Nineteen studies met the inclusion criteria. The evidence for validity reported varied by secondary data sources examined, primary data-gathering approaches, retail food outlets examined, and geographic and sociodemographic characteristics. More than half of the studies (53%) did not report evidence for validity by type of food outlet examined and by a particular secondary data source. Researchers should strive to gather primary data but if relying on secondary data sources, InfoUSA and government food registries had higher levels of agreement than reported by other secondary data sources and may provide sufficient accuracy for exploring these associations in large study areas. Published by Elsevier Inc. on behalf of American Journal of Preventive Medicine.

  12. Out-of-home food outlets and area deprivation: case study in Glasgow, UK

    PubMed Central

    Macintyre, Sally; McKay, Laura; Cummins, Steven; Burns, Cate

    2005-01-01

    Background There is a popular belief that out-of-home eating outlets, which typically serve energy dense food, may be more commonly found in more deprived areas and that this may contribute to higher rates of obesity and related diseases in such areas. Methods We obtained a list of all 1301 out-of-home eating outlets in Glasgow, UK, in 2003 and mapped these at unit postcode level. We categorised them into quintiles of area deprivation using the 2004 Scottish Index of Multiple Deprivation and computed mean density of types of outlet (restaurants, fast food restaurants, cafes and takeaways), and all types combined, per 1000 population. We also estimated odds ratios for the presence of any outlets in small areas within the quintiles. Results The density of outlets, and the likelihood of having any outlets, was highest in the second most affluent quintile (Q2) and lowest in the second most deprived quintile (Q4). Mean outlets per 1,000 were 4.02 in Q2, 1.20 in Q4 and 2.03 in Q5. With Q2 as the reference, Odds Ratios for having any outlets were 0.52 (CI 0.32–0.84) in Q1, 0.50 (CI 0.31 – 0.80) in Q4 and 0.61 (CI 0.38 – 0.98) in Q5. Outlets were located in the City Centre, West End, and along arterial roads. Conclusion In Glasgow those living in poorer areas are not more likely to be exposed to out-of-home eating outlets in their neighbourhoods. Health improvement policies need to be based on empirical evidence about the location of fast food outlets in specific national and local contexts, rather than on popular 'factoids'. PMID:16248898

  13. Obesity-promoting food environments and the spatial clustering of food outlets around schools.

    PubMed

    Day, Peter L; Pearce, Jamie

    2011-02-01

    The increasing prevalence of overweight and obesity in school-aged children is potentially linked to contextual influences such as the food environment around schools. The proximity of fast-food and convenience stores to schools may enhance access to unhealthy foods and have a negative impact on diet. This study used spatial cluster analysis to determine whether food outlets are clustered around schools and evaluated the extent of food outlet clustering by school and school neighborhood sociodemographic characteristics. The locations in 2008 of all schools, fast-food outlets, and convenience stores in five urban regions across New Zealand were geocoded. Using GIS analysis conducted in 2009, the number and proportion of outlets within 400-m and 800-m road distance around each school was calculated. The spatial clustering of food outlets within 1.5 km of schools was determined using a multi-type K-function. Food outlet type, school level, SES, the degree of population density, and commercial land use zoning around each school were compared. Primary/intermediate schools had a total proportion of 19.3 outlets per 1000 students within 800 m compared to 6.6 for secondary schools. The most socially deprived quintile of schools had three times the number and proportion of food outlets compared to the least-deprived quintile. There was a high degree of clustering of food outlets around schools, with up to 5.5 times more outlets than might be expected. Outlets were most clustered up to 800 m from schools and around secondary schools, socially deprived schools, and schools in densely populated and commercially zoned areas. Food environments in New Zealand within walking proximity to schools are characterized by a high density of fast-food outlets and convenience stores, particularly in more-socially deprived settings. These obesogenic environments provide ready access to obesity-promoting foods that may have a negative impact on student diet and contribute to inequalities in

  14. 49. OUTLET WORKS: THREE TON CRANE, ELECTRICAL SYSTEM NO 4. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    49. OUTLET WORKS: THREE TON CRANE, ELECTRICAL SYSTEM NO 4. Sheet H-4, December 12, 1939. File no. SA 342/60. - Prado Dam, Outlet Works, Santa Ana River near junction of State Highways 71 & 91, Corona, Riverside County, CA

  15. 8. CLOSEUP OF THE GATES ON THE TOBY CREEK OUTLET ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    8. CLOSEUP OF THE GATES ON THE TOBY CREEK OUTLET AND THE OUTLET OF THE PUMP DISCHARGE CHANNEL, LOOKING NORTHEAST. - Wyoming Valley Flood Control System, Woodward Pumping Station, East of Toby Creek crossing by Erie-Lackawanna Railroad, Edwardsville, Luzerne County, PA

  16. 22. UPSTREAM VIEW OF THE OUTLET CONTROL STRUCTURE AND THE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    22. UPSTREAM VIEW OF THE OUTLET CONTROL STRUCTURE AND THE PIER FOR THE SERVICE BRIDGE.... Volume XVIII, No. 12, January 29, 1940. - Prado Dam, Outlet Works, Santa Ana River near junction of State Highways 71 & 91, Corona, Riverside County, CA

  17. 46 CFR 34.20-20 - Discharge outlets-T/ALL.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... least one mounted foam appliance shall be provided for each station that is required in § 34.20-15(c). (c) The number of hand-held appliances provided shall be at least equal to the number of hose outlets at the two foam stations having the most hose outlets. Hand-held appliances shall be stowed in a well...

  18. The ecology of domestic violence: the role of alcohol outlet density.

    PubMed

    Livingston, Michael

    2010-11-01

    Studies have consistently found positive associations between the density of alcohol outlets and levels of violence in areas. Few studies have examined whether this relationship holds for domestic violence. This study assesses whether alcohol outlet density is related to domestic violence and whether this relationship is due to alcohol availability or to co-occurring economic disadvantage and social disorganisation. Cross-sectional data on family incidents, liquor outlets and socio-demographic characteristics were obtained for 217 postcodes in Melbourne, Australia. These data were used to construct models assessing the association between alcohol outlet density and domestic violence, both with and without controlling for socio-demographic factors. Models were tested for spatial autocorrelation, and spatial- error models were developed to control for its influence. Outlet density was significantly associated with rates of domestic violence, even controlling for socio-demographic factors. The density of hotels (pubs) was positively associated with domestic violence rates and the density of restaurants and bars was negatively associated with domestic violence. Socio-economic disadvantage was also associated with domestic violence rates. The density of packaged liquor outlets was not associated with rates of domestic violence. The results present a mixed picture, and further study is required to develop a clearer understanding of the links between alcohol availability and domestic violence.

  19. Effects of Outlets on Cracking Risk and Integral Stability of Super-High Arch Dams

    PubMed Central

    Hu, Hang

    2014-01-01

    In this paper, case study on outlet cracking is first conducted for the Goupitan and Xiaowan arch dams. A nonlinear FEM method is then implemented to study effects of the outlets on integral stability of the Xiluodu arch dam under two loading conditions, i.e., normal loading and overloading conditions. On the basis of the case study and the numerical modelling, the outlet cracking mechanism, risk, and corresponding reinforcement measures are discussed. Furthermore, the numerical simulation reveals that (1) under the normal loading conditions, the optimal distribution of the outlets will contribute to the tensile stress release in the local zone of the dam stream surface and decrease the outlet cracking risk during the operation period. (2) Under the overloading conditions, the cracks initiate around the outlets, then propagate along the horizontal direction, and finally coalesce with those in adjacent outlets, where the yield zone of the dam has a shape of butterfly. Throughout this study, a dam outlet cracking risk control and reinforcement principle is proposed to optimize the outlet design, select the appropriate concrete material, strengthen the temperature control during construction period, design reasonable impounding scheme, and repair the cracks according to their classification. PMID:25152907

  20. Kinetic modeling on CO₂ capture using basic oxygen furnace slag coupled with cold-rolling wastewater in a rotating packed bed.

    PubMed

    Chang, E-E; Chen, Tse-Lun; Pan, Shu-Yuan; Chen, Yi-Hung; Chiang, Pen-Chi

    2013-09-15

    In this study, direct and indirect carbonation of basic oxygen furnace slag (BOFS) coupled with cold-rolling wastewater (CRW) was carried out via a rotating packed bed (RPB). The solid products were qualitatively characterized by scanning electron microscopy (SEM) and X-ray diffraction (XRD) and quantitatively analyzed with thermogravimetric analysis (TGA). The leachate was analyzed with inductively coupled plasma-optical emission spectroscopy (ICP-OES). The results indicate that the maximum achievable carbonation conversion (MACC) of BOFS was 90.7%, corresponding to a capture capacity of 0.277 g CO₂/g of BOFS, by direct carbonation with CRW under a rotation speed of 750 rpm at 30 °C for 20 min. In addition, CO₂ mass balance among the gas, liquid, and solid phases within an RPB was well-developed, with an error less than 10%, to confirm the actual CO₂ capture capacity of BOFS with precision and accuracy. Furthermore, a reaction kinetic model based on mass balance was established to determine the reaction rate constant for various liquid agents (CRW and pure water). It was concluded that co-utilization of alkaline wastes including BOFS and CRW via the RPB is a novel approach for both enhancing CO₂ capture capacity and reducing the environmental impacts of alkaline wastes. Copyright © 2013 Elsevier B.V. All rights reserved.

  1. 104. DRY CREEK OUTLET (SPILL), TWIN FALLS COUNTY, SOUTH OF ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    104. DRY CREEK OUTLET (SPILL), TWIN FALLS COUNTY, SOUTH OF MURTAUGH, IDAHO; OUTLET FOR MURTAUGH LAKE, SOUTHEAST VIEW. - Milner Dam & Main Canal: Twin Falls Canal Company, On Snake River, 11 miles West of city of Burley, Idaho, Twin Falls, Twin Falls County, ID

  2. 25. UPSTREAM VIEW OF LOWER END OF OUTLET STRUCTURE SHOWING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    25. UPSTREAM VIEW OF LOWER END OF OUTLET STRUCTURE SHOWING FORMS IN PLACE FOR GRAVITY WALL SECTIONS.... Volume XVI, No. 16, August 16, 1939. - Prado Dam, Outlet Works, Santa Ana River near junction of State Highways 71 & 91, Corona, Riverside County, CA

  3. Tobacco retail outlet density and risk of youth smoking in New Zealand.

    PubMed

    Marsh, Louise; Ajmal, Ali; McGee, Rob; Robertson, Lindsay; Cameron, Claire; Doscher, Crile

    2016-12-01

    Evidence suggests inconsistent findings on the relationship between density of tobacco outlets around schools and risk of smoking among students. This study examines the density of tobacco outlets around secondary schools in New Zealand (NZ) and current smoking, experimental smoking, susceptibility to smoking, and attempted and successful tobacco purchasing. Smoking data came from the 2012 ASH Year 10 survey, a national survey of youth smoking in NZ. Geographic Information Systems were used to map tobacco retail outlets; a layer of secondary school locations was obtained from Koordinates.com. Logistic regression examined the relationship between density of outlets around schools and smoking behaviours, adjusting for individual-level and school-level confounders. Of the 27 238 students surveyed, 3.5% (952) were current smokers, 4.1% (n=1 128) were experimental smokers, and 39.8% (10 454) of nonsmokers were susceptible to smoking. An inverse relationship was found between the density of tobacco retail outlets and current smoking. Current smokers were significantly more likely to attempt to purchase tobacco if the density of tobacco retail outlets around their school was high. Non-smoking students were more likely to be susceptible to smoking if the density of tobacco outlets around their school was high. There was no statistically significant association between density of tobacco outlets and successful purchasing, nor experimental smoking. Restricting the permitted density of tobacco retail outlets around schools should be part of comprehensive tobacco control. In this regard, both smokers and non-smokers support the introduction of increased regulation of the tobacco retail environment to achieve our national smoke-free 2025 goal. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  4. Availability of healthier options in traditional and nontraditional rural fast-food outlets

    PubMed Central

    Creel, Jennifer S; Sharkey, Joseph R; McIntosh, Alex; Anding, Jenna; Huber, J Charles

    2008-01-01

    Background Food prepared away from home has become increasingly popular to U.S. families, and may contribute to obesity. Sales have been dominated by fast food outlets, where meals are purchased for dining away from home or in the home. Although national chain affiliated fast-food outlets are considered the main source for fast food, fast foods are increasingly available in convenience stores and supermarkets/grocery stores. In rural areas, these nontraditional fast-food outlets may provide most of the opportunities for procurement of fast foods. Methods Using all traditional and nontraditio nal fast-food outlets identified in six counties in rural Texas, the type and number of regular and healthiermenu options were surveyed using on-site observation in all food venues that were primarily fast food, supermarket/grocery store, and convenience store and compared with 2005 Dietary Guidelines. Results Traditional fast-food outlets represented 84 (41%) of the 205 opportunities for procurement of fast food; 109 (53.2%) were convenience stores and 12 (5.8%) supermarkets/grocery stores. Although a s imilar variety of regular breakfast and lunch/dinner entrées were available in traditional fast-food outlets and convenience stores, the variety of healthier breakfast and lunch/dinner entrées was significantly greater in fast food outlets. Compared with convenience stores, supermarkets/grocery stores provided a greater variety of regular and healthier entrées and lunch/dinner side dishes. Conclusion Convenience stores and supermarkets/grocery stores more than double the potential access to fast foods in this rural area than traditional fast-food outlets alone; however, traditional fast food outlets offer greater opportunity for healthier fast food options than convenience stores. A complete picture of fast food environment and the availability of healthier fast food options are essential to understand environmental influences on diet and health outcomes, and identify

  5. Alcohol outlet availability and excessive alcohol consumption in breast cancer survivors.

    PubMed

    Schootman, Mario; Deshpande, Anjali D; Lynskey, Michael T; Pruitt, Sandi L; Lian, Min; Jeffe, Donna B

    2013-01-01

    Breast cancer survivors who consume alcohol excessively are at increased risk of recurrence and have worse prognosis. Because the environments in which people live shape many health behaviors, there has been increased attention to how neighborhood environments (eg, alcohol outlet availability) may influence alcohol consumption. The authors hypothesized that proximity to alcohol outlets increases the likelihood of excessive consumption (ie, more than 1 drink/day) among breast cancer survivors independent of their personal or neighborhood characteristics. With the Missouri Cancer Registry, the authors conducted a cross-sectional study of 1047 female breast cancer survivors (aged 27-96 years) 1 year after diagnosis. Using telephone interviews, the authors obtained data regarding survivors' alcohol consumption during the past 30 days and several covariates of alcohol use. They also obtained street addresses of all licensed alcohol outlets in Missouri and calculated the road network distance between a participant's address of residence and the nearest alcohol outlet, using a geographic information system. Logistic regression was used to determine if distance was independently associated with excessive alcohol consumption. Eighteen percent of participants reported consuming more than 1 drink on average per day. Women who lived within 3 miles of the nearest outlet were more likely to report excessive alcohol consumption (odds ratio: 2.09; 95% confidence interval: 1.08, 4.05) than women who lived at least 3 miles from the nearest outlet in adjusted analysis. Opportunities exist to reduce excessive alcohol use among breast cancer survivors through policy (eg, restricting number of alcohol outlets) and behavioral (eg, counseling) interventions.

  6. 46 CFR 153.352 - B/3 and 4 m venting system outlets.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 5 2011-10-01 2011-10-01 false B/3 and 4 m venting system outlets. 153.352 Section 153.352 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES... Cargo Venting Systems § 153.352 B/3 and 4 m venting system outlets. A B/3 or 4 m venting system outlet...

  7. 46 CFR 153.352 - B/3 and 4 m venting system outlets.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false B/3 and 4 m venting system outlets. 153.352 Section 153.352 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES... Cargo Venting Systems § 153.352 B/3 and 4 m venting system outlets. A B/3 or 4 m venting system outlet...

  8. Control of occupational exposure to phenol in industrial wastewater treatment plant of a petroleum refinery in Alexandria, Egypt: An intervention application case study.

    PubMed

    Zaki, Gehan R; El-Marakby, Fadia A; Ramadan, Alaa El-Din K; Issa, Ahmed I; Nofal, Faten H

    2016-11-01

    Phenol exposure is one of the hazards in the industrial wastewater treatment basin of any refinery. It additively interacts with hydrogen sulfide emitted from the wastewater basin. Consequently, its concentration should be greatly lower than its threshold limit value. The present study aimed at controlling occupational exposure to phenol in the work environment of wastewater treatment plant in a refinery by reducing phenolic compounds in the industrial wastewater basin. This study was conducted on both laboratory and refinery scales. The first was completed by dividing each wastewater sample from the outlets of different refinery units into three portions; the first was analyzed for phenolic compounds. The second and third were for laboratory scale charcoal and bacterial treatments. The two methods were compared regarding their simplicities, design, and removal efficiencies. Accordingly, bacterial treatment by continuous flow of sewage water containing Pseudomonas Aeruginosa was used for refinery scale treatment. Laboratory scale treatment of phenolic compounds revealed higher removal efficiency of charcoal [100.0(0.0) %] than of bacteria [99.9(0.013) %]. The refinery scale bacterial treatment was [99.8(0.013) %] efficient. Consequently, level of phenol in the work environment after refinery-scale treatment [0.069(0.802) mg/m(3)] was much lower than that before [5.700(26.050) mg/m(3)], with removal efficiency of [99.125(2.335) %]. From the present study, we can conclude that bacterial treatment of phenolic compounds in industrial wastewater of the wastewater treatment plant using continuous flow of sewage water containing Pseudomonas Aeruginosa reduces the workers' exposure to phenol.

  9. 7 CFR 981.467 - Disposition in reserve outlets by handlers.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Disposition in reserve outlets by handlers. 981.467 Section 981.467 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL... ALMONDS GROWN IN CALIFORNIA Administrative Rules and Regulations § 981.467 Disposition in reserve outlets...

  10. 6. VIEW OF DAM 83, SHOWING OUTLET CHANNEL FLOWING INTO ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    6. VIEW OF DAM 83, SHOWING OUTLET CHANNEL FLOWING INTO POND A WITH DIVERSION GATES LONG EAST (LEFT) SIDE OF OUTLET CHANNEL, LOOKING SOUTH FROM DOWNSTREAM FACE OF THE DAM - Upper Souris National Wildlife Refuge, Dam 83, Souris River Basin, Foxholm, Surrey (England), ND

  11. 46 CFR 108.459 - Number and location of outlets.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... outlets. (a) A foam extinguishing system in a space must have enough outlets to spread a layer of foam of uniform thickness over the deck or bilge areas of the space. (b) A foam extinguishing system in a space that has a boiler on a flat that is open to or can drain into a lower portion of the space must have...

  12. 46 CFR 108.459 - Number and location of outlets.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... outlets. (a) A foam extinguishing system in a space must have enough outlets to spread a layer of foam of uniform thickness over the deck or bilge areas of the space. (b) A foam extinguishing system in a space that has a boiler on a flat that is open to or can drain into a lower portion of the space must have...

  13. 46 CFR 108.459 - Number and location of outlets.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... outlets. (a) A foam extinguishing system in a space must have enough outlets to spread a layer of foam of uniform thickness over the deck or bilge areas of the space. (b) A foam extinguishing system in a space that has a boiler on a flat that is open to or can drain into a lower portion of the space must have...

  14. 46 CFR 108.459 - Number and location of outlets.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... outlets. (a) A foam extinguishing system in a space must have enough outlets to spread a layer of foam of uniform thickness over the deck or bilge areas of the space. (b) A foam extinguishing system in a space that has a boiler on a flat that is open to or can drain into a lower portion of the space must have...

  15. 46 CFR 108.459 - Number and location of outlets.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... outlets. (a) A foam extinguishing system in a space must have enough outlets to spread a layer of foam of uniform thickness over the deck or bilge areas of the space. (b) A foam extinguishing system in a space that has a boiler on a flat that is open to or can drain into a lower portion of the space must have...

  16. State-of-the-art Magnetic Resonance Imaging in Vascular Thoracic Outlet Syndrome.

    PubMed

    Aghayev, Ayaz; Rybicki, Frank J

    2015-05-01

    Vascular thoracic outlet syndrome is caused by compression of subclavian/axillary vessels during their passage from the thoracic cavity to the axilla. Early diagnosis and treatment is important to prevent debilitating outcomes of vascular thoracic outlet syndrome. Contrast-enhanced three-dimensional (3D) magnetic resonance angiography (MRA) with equilibrium phase using provocative arm positioning is the optimal examination to determine presence, degree of vascular compression, and complications of vascular thoracic outlet syndrome. This article reviews thoracic outlet anatomy, disorders of the vascular component, and typical imaging findings by contrast-enhanced 3D MRA. Published by Elsevier Inc.

  17. Alcohol outlet availability and excessive alcohol consumption in breast cancer survivors

    PubMed Central

    Schootman, Mario; Deshpande, Anjali D.; Lynskey, Michael; Pruitt, Sandi L.; Lian, Min; Jeffe, Donna B.

    2014-01-01

    Introduction Breast cancer survivors who consume alcohol excessively are at increased risk of recurrence and have worse prognosis. Because the environments in which people live shape many health behaviors, there has been increased attention to how neighborhood environments (e.g., alcohol outlet availability) may influence alcohol consumption. We hypothesized that proximity to alcohol outlets increases the likelihood of excessive consumption (i.e., more than one drink/day) among breast cancer survivors independent of their personal or neighborhood characteristics. Methods With the Missouri Cancer Registry, we conducted a cross-sectional study of 1047 female breast cancer survivors (aged 27–96 years) one year after diagnosis. Using telephone interviews, we obtained data regarding survivors’ alcohol consumption during the past 30 days and several covariates of alcohol use. We also obtained street addresses of all licensed alcohol outlets in Missouri and calculated the road network distance between a participant’s address of residence and the nearest alcohol outlet using a geographic information system. We used logistic regression to determine if distance was independently associated with excessive alcohol consumption or not. Results Eighteen percent of participants reported consuming more than one drink on average per day. Women who lived within 3 miles of the nearest outlet were more likely to report excessive alcohol consumption (OR: 2.09; 95% CI: 1.08 – 4.05) than women who lived at least 3 miles from the nearest outlet in adjusted analysis. Discussion Opportunities exist to reduce excessive alcohol use among breast cancer survivors through policy (e.g., restricting number of alcohol outlets) and behavioral (e.g., counseling) interventions. PMID:23799690

  18. Effect of heat recovery from raw wastewater on nitrification and nitrogen removal in activated sludge plants.

    PubMed

    Wanner, Oskar; Panagiotidis, Vassileios; Clavadetscher, Peter; Siegrist, Hansruedi

    2005-11-01

    By recovery of heat from the raw wastewater in the sewer system, the influent temperature of a wastewater treatment plant (WWTP) is reduced. This can have a negative effect on nitrification in the WWTP, since this process strongly depends on temperature. The analysis of the temperature regime in the WWTP of Zurich, Switzerland, revealed that in the cold season, the effluent temperature is about 0.7 degrees C higher than the influent temperature and that nitrification is not affected by a decrease of the influent wastewater temperature lasting for a couple of hours only, but is significantly affected by a longer lasting temperature decrease. Three diagrams were developed with a steady-state model, from which the consequences of a permanent temperature decrease on the nitrification safety factor, aerobic sludge retention time and total nitrogen removal can be evaluated. Using simulations with a dynamic model, calibrated for the Zurich WWTP, a quantitative relationship between the wastewater temperature and the ammonium effluent concentration was established. This relationship can, in combination with measured effluent concentrations of an existing WWTP, be used to predict the increase of the ammonium effluent concentration in this plant resulting from a permanent decrease of the wastewater influent temperature.

  19. Associations between proximity and density of local alcohol outlets and alcohol use among Scottish adolescents.

    PubMed

    Young, Robert; Macdonald, Laura; Ellaway, Anne

    2013-01-01

    Associations between different alcohol outcomes and outlet density measures vary between studies and may not be generalisable to adolescents. In a cross-sectional study of 979 15-year old Glaswegians, we investigated the association between alcohol outlet availability (outlet density and proximity), outlet type (on-premise vs. off-premise) and frequent (weekly) alcohol consumption. We adjusted for social background (gender, social class, family structure). Proximity and density of on-premise outlets were not associated with weekly drinking. However, adolescents living close (within 200 m) to an off-sales outlet were more likely to drink frequently (OR 1.97, p=0.004), as were adolescents living in areas with many nearby off-premises outlets (OR 1.60, p=0.016). Our findings suggest that certain alcohol behaviours (e.g. binge drinking) may be linked to the characteristics of alcohol outlets in the vicinity. Copyright © 2012 Elsevier Ltd. All rights reserved.

  20. Associations between proximity and density of local alcohol outlets and alcohol use among Scottish adolescents

    PubMed Central

    Young, Robert; Macdonald, Laura; Ellaway, Anne

    2013-01-01

    Associations between different alcohol outcomes and outlet density measures vary between studies and may not be generalisable to adolescents. In a cross-sectional study of 979 15-year old Glaswegians, we investigated the association between alcohol outlet availability (outlet density and proximity), outlet type (on-premise vs. off-premise) and frequent (weekly) alcohol consumption. We adjusted for social background (gender, social class, family structure). Proximity and density of on-premise outlets were not associated with weekly drinking. However, adolescents living close (within 200 m) to an off-sales outlet were more likely to drink frequently (OR 1.97, p=0.004), as were adolescents living in areas with many nearby off-premises outlets (OR 1.60, p=0.016). Our findings suggest that certain alcohol behaviours (e.g. binge drinking) may be linked to the characteristics of alcohol outlets in the vicinity. PMID:23220375

  1. High performance constructed wetlands for cold climates.

    PubMed

    Jenssen, Petter D; Maehlum, Trend; Krogstad, Tore; Vråle, Lasse

    2005-01-01

    In 1991, the first subsurface flow constructed wetland for treatment of domestic wastewater was built in Norway. Today, this method is rapidly becoming a popular method for wastewater treatment in rural Norway. This is due to excellent performance even during winter and low maintenance. The systems can be constructed regardless of site conditions. The Norwegian concept for small constructed wetlands is based on the use of a septic tank followed by an aerobic vertical down-flow biofilter succeeded by a subsurface horizontal-flow constructed wetland. The aerobic biofilter, prior to the subsurface flow stage, is essential to remove BOD and achieve nitrification in a climate where the plants are dormant during the cold season. When designed according to present guidelines a consistent P-removal of > 90% can be expected for 15 years using natural iron or calcium rich sand or a new manufactured lightweight aggregate with P-sorption capacities, which exceeds most natural media. When the media is saturated with P it can be used as soil conditioner and P-fertilizer. Nitrogen removal in the range of 40-60% is achieved. Removal of indicator bacteria is high and < 1000 thermotolerant coliforms/100 ml is normally achieved.

  2. 40 CFR 63.133 - Process wastewater provisions-wastewater tanks.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 10 2014-07-01 2014-07-01 false Process wastewater provisions-wastewater tanks. 63.133 Section 63.133 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... Chemical Manufacturing Industry for Process Vents, Storage Vessels, Transfer Operations, and Wastewater...

  3. 40 CFR 63.133 - Process wastewater provisions-wastewater tanks.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 10 2012-07-01 2012-07-01 false Process wastewater provisions-wastewater tanks. 63.133 Section 63.133 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... Chemical Manufacturing Industry for Process Vents, Storage Vessels, Transfer Operations, and Wastewater...

  4. 40 CFR 63.133 - Process wastewater provisions-wastewater tanks.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 9 2011-07-01 2011-07-01 false Process wastewater provisions-wastewater tanks. 63.133 Section 63.133 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... Chemical Manufacturing Industry for Process Vents, Storage Vessels, Transfer Operations, and Wastewater...

  5. 40 CFR 63.133 - Process wastewater provisions-wastewater tanks.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 10 2013-07-01 2013-07-01 false Process wastewater provisions-wastewater tanks. 63.133 Section 63.133 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... Chemical Manufacturing Industry for Process Vents, Storage Vessels, Transfer Operations, and Wastewater...

  6. 48. OUTLET WORKS: ELECTRICAL SYSTEM NO. 3. Sheet H3, October, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    48. OUTLET WORKS: ELECTRICAL SYSTEM NO. 3. Sheet H-3, October, 1939. File no. SA 342/59. - Prado Dam, Outlet Works, Santa Ana River near junction of State Highways 71 & 91, Corona, Riverside County, CA

  7. Automated determinations of selenium in thermal power plant wastewater by sequential hydride generation and chemiluminescence detection.

    PubMed

    Ezoe, Kentaro; Ohyama, Seiichi; Hashem, Md Abul; Ohira, Shin-Ichi; Toda, Kei

    2016-02-01

    After the Fukushima disaster, power generation from nuclear power plants in Japan was completely stopped and old coal-based power plants were re-commissioned to compensate for the decrease in power generation capacity. Although coal is a relatively inexpensive fuel for power generation, it contains high levels (mgkg(-1)) of selenium, which could contaminate the wastewater from thermal power plants. In this work, an automated selenium monitoring system was developed based on sequential hydride generation and chemiluminescence detection. This method could be applied to control of wastewater contamination. In this method, selenium is vaporized as H2Se, which reacts with ozone to produce chemiluminescence. However, interference from arsenic is of concern because the ozone-induced chemiluminescence intensity of H2Se is much lower than that of AsH3. This problem was successfully addressed by vaporizing arsenic and selenium individually in a sequential procedure using a syringe pump equipped with an eight-port selection valve and hot and cold reactors. Oxidative decomposition of organoselenium compounds and pre-reduction of the selenium were performed in the hot reactor, and vapor generation of arsenic and selenium were performed separately in the cold reactor. Sample transfers between the reactors were carried out by a pneumatic air operation by switching with three-way solenoid valves. The detection limit for selenium was 0.008 mg L(-1) and calibration curve was linear up to 1.0 mg L(-1), which provided suitable performance for controlling selenium in wastewater to around the allowable limit (0.1 mg L(-1)). This system consumes few chemicals and is stable for more than a month without any maintenance. Wastewater samples from thermal power plants were collected, and data obtained by the proposed method were compared with those from batchwise water treatment followed by hydride generation-atomic fluorescence spectrometry. Copyright © 2015 Elsevier B.V. All rights

  8. Nondeterministic computational fluid dynamics modeling of Escherichia coli inactivation by peracetic acid in municipal wastewater contact tanks.

    PubMed

    Santoro, Domenico; Crapulli, Ferdinando; Raisee, Mehrdad; Raspa, Giuseppe; Haas, Charles N

    2015-06-16

    Wastewater disinfection processes are typically designed according to heuristics derived from batch experiments in which the interaction among wastewater quality, reactor hydraulics, and inactivation kinetics is often neglected. In this paper, a computational fluid dynamics (CFD) study was conducted in a nondeterministic (ND) modeling framework to predict the Escherichia coli inactivation by peracetic acid (PAA) in municipal contact tanks fed by secondary settled wastewater effluent. The extent and variability associated with the observed inactivation kinetics were both satisfactorily predicted by the stochastic inactivation model at a 95% confidence level. Moreover, it was found that (a) the process variability induced by reactor hydraulics is negligible when compared to the one caused by inactivation kinetics, (b) the PAA dose required for meeting regulations is dictated equally by the fixed limit of the microbial concentration as well as its probability of occurrence, and (c) neglecting the probability of occurrence during process sizing could lead to an underestimation of the PAA dose required by as much as 100%. Finally, the ND-CFD model was used to generate sizing information in the form of probabilistic disinfection curves relating E. coli inactivation and probability of occurrence with the average PAA dose and PAA residual concentration at the outlet of the contact tank.

  9. 49 CFR 178.346-4 - Outlets.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... must conform to § 178.345-11 and this section. (b) External self-closing stop-valves are not authorized as an alternative to internal self-closing stop-valves on loading/unloading outlets. [Amdt. 178-89...

  10. 1. View east at west facade of culvert outlet headwall, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. View east at west facade of culvert outlet headwall, above which part of the canal bank has been removed. Foreground to background: streambed and coffer dam (mound in center) that was used in dewatering the culvert; intake pipes (extreme left and right) for dewatering pumps; deteriorated culvert outlet headwall with upper portion of wall fallen away; horizontal masonry cutoff wall extending above the culvert outlet partially up the canal bank (cutoff wall was exposed by removal of part of canal bank); towpath at top of canal bank. - Delaware & Raritan Canal, Six Mile Run Culvert, .2 mile South of Blackwells Mills Road, East Millstone, Somerset County, NJ

  11. Venous Thoracic Outlet Syndrome as a Cause of Intractable Migraines.

    PubMed

    Chahwala, Veer; Tashiro, Jun; Li, Xiaoyi; Baqai, Atif; Rey, Jorge; Robinson, Handel R

    2017-02-01

    Thoracic outlet syndrome (TOS) refers to the compression of the neurovascular bundle within the thoracic outlet. Cases are classified by primary etiology-arterial, neurogenic, or venous. In addition to the typical symptoms of arm swelling and paresthesias, headaches have been reported as a potential symptom of TOS. In this report, we describe a patient with debilitating migraines, which were consistently preceded by unilateral arm swelling. Resolution of symptoms occurred only after thoracic outlet decompression. Patients with migraines and concomitant swelling and/or paresthesias, especially related to provocative arm maneuvers, should be considered a possible atypical presentation of TOS and evaluated in more detail. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. 40. OUTLET WORKS: VIBRATION ABSORBER FOR STANDBY UNIT, Sheet H7, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    40. OUTLET WORKS: VIBRATION ABSORBER FOR STANDBY UNIT, Sheet H-7, September, 1940. File no. SA 342/79. - Prado Dam, Outlet Works, Santa Ana River near junction of State Highways 71 & 91, Corona, Riverside County, CA

  13. Fate of Volatile Organic Compounds in Constructed Wastewater Treatment Wetlands

    USGS Publications Warehouse

    Keefe, S.H.; Barber, L.B.; Runkel, R.L.; Ryan, J.N.

    2004-01-01

    The fate of volatile organic compounds was evaluated in a wastewater-dependent constructed wetland near Phoenix, AZ, using field measurements and solute transport modeling. Numerically based volatilization rates were determined using inverse modeling techniques and hydraulic parameters established by sodium bromide tracer experiments. Theoretical volatilization rates were calculated from the two-film method incorporating physicochemical properties and environmental conditions. Additional analyses were conducted using graphically determined volatilization rates based on field measurements. Transport (with first-order removal) simulations were performed using a range of volatilization rates and were evaluated with respect to field concentrations. The inverse and two-film reactive transport simulations demonstrated excellent agreement with measured concentrations for 1,4-dichlorobenzene, tetrachloroethene, dichloromethane, and trichloromethane and fair agreement for dibromochloromethane, bromo-dichloromethane, and toluene. Wetland removal efficiencies from inlet to outlet ranged from 63% to 87% for target compounds.

  14. 47. OUTLET WORKS: ELECTRICAL SYSTEM NO. 2. Sheet H2, date ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    47. OUTLET WORKS: ELECTRICAL SYSTEM NO. 2. Sheet H-2, date stamped May, 1939. File no. SA 342/10. - Prado Dam, Outlet Works, Santa Ana River near junction of State Highways 71 & 91, Corona, Riverside County, CA

  15. 46. OUTLET WORKS: ELECTRICAL SYSTEM NO. 1. Sheet H1, date ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    46. OUTLET WORKS: ELECTRICAL SYSTEM NO. 1. Sheet H-1, date stamped May, 1939. File no. SA 342/9. - Prado Dam, Outlet Works, Santa Ana River near junction of State Highways 71 & 91, Corona, Riverside County, CA

  16. 29. OUTLET WORKS: GENERAL PLAN AND SECTIONS. Sheet A1, date ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    29. OUTLET WORKS: GENERAL PLAN AND SECTIONS. Sheet A-1, date stamped January, 1939. File no. SA 949/80. - Prado Dam, Outlet Works, Santa Ana River near junction of State Highways 71 & 91, Corona, Riverside County, CA

  17. Varying impacts of alcohol outlet densities on violent assaults: explaining differences across neighborhoods.

    PubMed

    Mair, Christina; Gruenewald, Paul J; Ponicki, William R; Remer, Lillian

    2013-01-01

    Groups of potentially violent drinkers may frequent areas of communities with large numbers of alcohol outlets, especially bars, leading to greater rates of alcohol-related assaults. This study assessed direct and moderating effects of bar densities on assaults across neighborhoods. We analyzed longitudinal population data relating alcohol outlet densities (total outlet density, proportion bars/pubs, proportion off-premise outlets) to hospitalizations for assault injuries in California across residential ZIP code areas from 1995 through 2008 (23,213 space-time units). Because few ZIP codes were consistently defined over 14 years and these units are not independent, corrections for unit misalignment and spatial autocorrelation were implemented using Bayesian space-time conditional autoregressive models. Assaults were related to outlet densities in local and surrounding areas, the mix of outlet types, and neighborhood characteristics. The addition of one outlet per square mile was related to a small 0.23% increase in assaults. A 10% greater proportion of bars in a ZIP code was related to 7.5% greater assaults, whereas a 10% greater proportion of bars in surrounding areas was related to 6.2% greater assaults. The impacts of bars were much greater in areas with low incomes and dense populations. The effect of bar density on assault injuries was well supported and positive, and the magnitude of the effect varied by neighborhood characteristics. Posterior distributions from these models enabled the identification of locations most vulnerable to problems related to alcohol outlets.

  18. Detention basin alternative outlet design study.

    DOT National Transportation Integrated Search

    2016-10-01

    This study examines the outlets structures CDOT has historically employed to drain water quality treatment detention basins and flood control basins, presents two new methods of metering the water quality capture volume (WQCV), namely 1) the Elliptic...

  19. Atmospheric pressure plasma jet for bacterial decontamination and property improvement of fruit and vegetable processing wastewater

    NASA Astrophysics Data System (ADS)

    Mohamed, Abdel-Aleam H.; Shariff, Samir M. Al; Ouf, Salama A.; Benghanem, Mohamed

    2016-05-01

    An atmospheric pressure plasma jet was tested for decontaminating and improving the characteristics of wastewater derived from blackberry, date palm, tomato and beetroot processing industries. The jet was generated by blowing argon gas through a cylindrical alumina tube while a high voltage was applied between two electrodes surrounding the tube. Oxygen gas was mixed with argon at the rate of 0.2% and the argon mass flow was fixed at 4.5 slm. Images show that the generated plasma jet penetrated the treated wastewater samples. Plasma emission spectra show the presence of O and OH radicals as well as excited molecular nitrogen and argon. Complete decontamination of wastewater derived from date palm and tomato processing was achieved after 120 and 150 s exposure to the plasma jet, respectively. The bacterial count of wastewater from blackberry and beetroot was reduced by 0.41 and 2.24 log10 colony-forming units (CFU) per ml, respectively, after 180 s. Escherichia coli was the most susceptible bacterial species to the cold plasma while Shigella boydii had the minimum susceptibility, recording 1.30 and 3.34 log10 CFU ml-1, respectively, as compared to the 7.00 log10 initial count. The chemical oxygen demands of wastewater were improved by 57.5-93.3% after 180 s exposure to the plasma jet being tested. The endotoxins in the wastewater were reduced by up to 90.22%. The variation in plasma effectiveness is probably related to the antioxidant concentration of the different investigated wastewaters.

  20. 7 CFR 987.56 - Outlets for utility and cull dates.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... finds that the use of utility dates of any variety in certain products for human consumption would tend to effectuate the declared policy of the act, the Secretary shall specify such products, and dates of..., alcohol, or brandy outlets, or in such other outlets for non-human food products as the Committee with the...

  1. Alcohol outlets, gonorrhea, and the Los Angeles civil unrest: A longitudinal analysis

    PubMed Central

    Cohen, Deborah A.; Ghosh-Dastidar, Bonnie; Scribner, Richard; Miu, Angela; Scott, Molly; Robinson, Paul; Farley, Thomas A.; Bluthenthal, Ricky N.; Brown-Taylor, Didra

    2007-01-01

    This study tests the effect of neighborhood changes on gonorrhea rates. Prior studies that indicate gonorrhea rates are associated with alcohol outlet density and neighborhood deterioration have been cross-sectional and cannot establish causality. After the 1992 Civil Unrest in Los Angeles, 270 alcohol outlets surrendered their licenses due to arson and vandalism thus providing a natural experiment. We geocoded all reported gonorrhea cases from 1988 to 1996 in LA County, all annually licensed alcohol outlets, and all properties damaged as a result of the civil unrest. We ran individual growth models to examine the independent effects of changes in alcohol outlets and damaged buildings on gonorrhea. The individual growth model explained over 90% of the residual variance in census tract gonorrhea rates. After the civil unrest, a unit decrease in the number of alcohol outlets per mile of roadway was associated with 21 fewer gonorrhea cases per 100,000 (p<.01) in tracts affected by the Unrest compared to those not affected. Neighborhood alcohol outlets appear to be significantly associated with changes in gonorrhea rates. The findings suggest that efforts to control sexually transmitted diseases, including gonorrhea and HIV, should address contextual factors that facilitate high-risk behaviors and disease transmission PMID:16423436

  2. The role of tobacco outlet density in a smoking cessation intervention for urban youth.

    PubMed

    Mennis, Jeremy; Mason, Michael; Way, Thomas; Zaharakis, Nikola

    2016-03-01

    This study investigates the role of tobacco outlet density in a randomized controlled trial of a text messaging-based smoking cessation intervention conducted among a sample of 187 primarily African American youth in a midsize U.S. city. A moderated mediation model was used to test whether the indirect effect of residential tobacco outlet density on future smoking was mediated by the intention to smoke, and whether this indirect effect differed between adolescents who received the intervention and those who did not. Results indicated that tobacco outlet density is associated with intention to smoke, which predicts future smoking, and that the indirect effect of tobacco outlet density on future smoking is moderated by the intervention. Tobacco outlet density and the intervention can be viewed as competing forces on future smoking behavior, where higher tobacco outlet density acts to mitigate the sensitivity of an adolescent to the intervention's intended effect. Smoking cessation interventions applied to youth should consider tobacco outlet density as a contextual condition that can influence treatment outcomes. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Hybrid activated sludge/biofilm process for the treatment of municipal wastewater in a cold climate region: a case study.

    PubMed

    Di Trapani, Daniele; Christensso, Magnus; Odegaard, Hallvard

    2011-01-01

    A hybrid activated sludge/biofilm process was investigated for wastewater treatment in a cold climate region. This process, which contains both suspended biomass and biofilm, usually referred as IFAS process, is created by introducing plastic elements as biofilm carrier media into a conventional activated sludge reactor. In the present study, a hybrid process, composed of an activated sludge and a moving bed biofilm reactor was used. The aim of this paper has been to investigate the performances of a hybrid process, and in particular to gain insight the nitrification process, when operated at relatively low MLSS SRT and low temperatures. The results of a pilot-scale study carried out at the Department of Hydraulic and Environmental Engineering at the Norwegian University of Science and Technology in Trondheim are presented. The experimental campaign was divided into two periods. The pilot plant was first operated with a constant HRT of 4.5 hours, while in the second period the influent flow was increased so that HRT was 3.5 hours. The average temperature was near 11.5°C in the overall experimental campaign. The average mixed liquor SRT was 5.7 days. Batch tests on both carriers and suspended biomass were performed in order to evaluate the nitrification rate of the two different biomasses. The results demonstrated that this kind of reactor can efficiently be used for the upgrading of conventional activated sludge plant for achieving year-round nitrification, also in presence of low temperatures, and without the need of additional volumes.

  4. Hydrological Modeling of the Jezero Crater Outlet-Forming Flood

    NASA Technical Reports Server (NTRS)

    Fassett, C. I.; Goudge, T. A.

    2017-01-01

    Abundant evidence exists for lakes on Mars both from orbital observations [e.g., 1-3] and in situ exploration [e.g., 4-5]. These lakes can be divided into two classes: those that were hydrologically closed, so their source valley(s) terminated at the basin [3], and those that were hydrologically open, where there was sufficient flow from inlet valley(s) to cause the lake to breach and form an outlet valley [2]. It is easier to be confident from orbital data alone that a standing body of water must have existed in open basins, because there is no other way for their perched outlet valleys to form. The majority of basins fed by valley networks, rather than by isolated inlet valleys, are open [6], with some important exceptions (e.g., Gale Crater). Jezero crater (Fig. 1) is one of the most well-studied open basin paleolakes on Mars, with a breach that re-mains well above the lowest part of the crater floor, and two sedimentary fans at its northwestern margin that are likely deltaic in origin [7-9]. CRISM observations of these sediments indicate they host a variety of alteration minerals [9-11], including smectite and carbonate, and both the mineralogy of the sediments and their settings suggest they have a strong potential for preserving organic materials [10]. As a result, Jezero is a strong candidate landing site for the Mars 2020 rover. Approximate formative discharges have been estimated for its well-preserved western fan (Q approximately 500m3/s) [7], but to our knowledge, no estimates for the dis-charges associated with formation and incision of its outlet valley have been presented. Indeed, only a few studies [e.g., 12-14] have attempted to reconstruct the formation of outlet breaches broadly similar to Jezero anywhere on Mars, despite the apparent commonality of basins with large outlets [e.g., 2]. The outlet valley formed as a dam breach when the lake overflowed. In such an event, the growth and incision of the breach is directly coupled to flood discharge

  5. A Geospatial Statistical Analysis of the Density of Lottery Outlets within Ethnically Concentrated Neighborhoods

    ERIC Educational Resources Information Center

    Wiggins, Lyna; Nower, Lia; Mayers, Raymond Sanchez; Peterson, N. Andrew

    2010-01-01

    This study examines the density of lottery outlets within ethnically concentrated neighborhoods in Middlesex County, New Jersey, using geospatial statistical analyses. No prior studies have empirically examined the relationship between lottery outlet density and population demographics. Results indicate that lottery outlets were not randomly…

  6. Hydrological Modeling of the Jezero Crater Outlet-Forming Flood

    NASA Technical Reports Server (NTRS)

    Fassett, Caleb I.; Goudge, Timothy A.

    2017-01-01

    Jezero crater is a site of prime scientific interest because it was a lake early in Mars history. Preserved clay- and carbonate-bearing sedimentary fans on Jezero's western and northwestern margin (Fig. 2) are accessible to future exploration. Geologic context [1] and stratigraphic analysis of the western fan strongly support the interpretation that these fans were deposited as deltas into the lake. This has helped establish Jezero as one of the final candidate landing sites for Mars 2020. The high level of certainty that Jezero was a lake results from the existence of its outlet valley, which required filling of the crater to form [e.g., 1,4]. Here, we specifically focus on how this outlet valley was carved by the dam breach flood that eroded the eastern crater rim. We have completed preliminary modeling in both 1D and 2D of the outlet's formation.

  7. Using public health and community partnerships to reduce density of alcohol outlets.

    PubMed

    Jernigan, David H; Sparks, Michael; Yang, Evelyn; Schwartz, Randy

    2013-04-11

    Excessive alcohol use causes approximately 80,000 deaths in the United States each year. The Guide to Community Preventive Services recommends reducing the density of alcohol outlets - the number of physical locations in which alcoholic beverages are available for purchase either per area or per population - through the use of regulatory authority as an effective strategy for reducing excessive alcohol consumption and related harms. We briefly review the research on density of alcohol outlets and public health and describe the powers localities have to influence alcohol outlet density. We summarize Regulating Alcohol Outlet Density: An Action Guide, which describes steps that local communities can take to reduce outlet density and the key competencies and resources of state and local health departments. These include expertise in public health surveillance and evaluation methods, identification and tracking of outcome measures, geographic information systems (GIS) mapping, community planning and development of multisector efforts, and education of community leaders and policy makers. We illustrate the potential for partnerships between public health agencies and local communities by presenting a contemporary case study from Omaha, Nebraska. Public health agencies have a vital and necessary role to play in efforts to reduce alcohol outlet density. They are often unaware of the potential of this strategy and have strong potential partners in the thousands of community coalitions nationwide that are focused on reducing alcohol-related problems.

  8. Using Public Health and Community Partnerships to Reduce Density of Alcohol Outlets

    PubMed Central

    Sparks, Michael; Yang, Evelyn; Schwartz, Randy

    2013-01-01

    Excessive alcohol use causes approximately 80,000 deaths in the United States each year. The Guide to Community Preventive Services recommends reducing the density of alcohol outlets — the number of physical locations in which alcoholic beverages are available for purchase either per area or per population — through the use of regulatory authority as an effective strategy for reducing excessive alcohol consumption and related harms. We briefly review the research on density of alcohol outlets and public health and describe the powers localities have to influence alcohol outlet density. We summarize Regulating Alcohol Outlet Density: An Action Guide, which describes steps that local communities can take to reduce outlet density and the key competencies and resources of state and local health departments. These include expertise in public health surveillance and evaluation methods, identification and tracking of outcome measures, geographic information systems (GIS) mapping, community planning and development of multisector efforts, and education of community leaders and policy makers. We illustrate the potential for partnerships between public health agencies and local communities by presenting a contemporary case study from Omaha, Nebraska. Public health agencies have a vital and necessary role to play in efforts to reduce alcohol outlet density. They are often unaware of the potential of this strategy and have strong potential partners in the thousands of community coalitions nationwide that are focused on reducing alcohol-related problems. PMID:23578401

  9. Assessing the relationship between alcohol outlets and domestic violence: routine activities and the neighborhood environment.

    PubMed

    Roman, Caterina G; Reid, Shannon E

    2012-01-01

    Studies have consistently found a positive relationship between alcohol outlet density and assault, but only a handful of studies have examined whether outlet density has an influence on domestic violence. Using a framework based in crime opportunity theories, this study estimates spatial econometric regression models to test whether the density of alcohol outlets across neighborhoods is positively associated with police calls for service for domestic violence. Models also were developed to test whether the relationships found were consistent across time periods associated with the use of alcohol outlets (weeknights and weekends). The findings indicate that off-premise outlets were associated with a significant increase in domestic violence, but on-premise outlets (specifically restaurants and nightclubs) were associated with a decrease in domestic violence. The risk for domestic violence in areas of high densities of off-premise outlets was found to be high during the weekend but not during the weeknight, suggesting different routine activities for domestic violence offenders during the week.

  10. Evaluating the heat pump alternative for heating enclosed wastewater treatment facilities in cold regions

    NASA Astrophysics Data System (ADS)

    Martel, C. J.; Phetteplace, G. E.

    1982-05-01

    This report presents a five-step procedure for evaluating the technical and economic feasibility of using heat pumps to recover heat from treatment plant effluent. The procedure is meant to be used at the facility planning level by engineers who are unfamiliar with this technology. An example of the use of the procedure and general design information are provided. Also, the report reviews the operational experience with heat pumps at wastewater plants located in Fairbanks, Alaska, Madison, Wisconsin, and Wilton, Maine.

  11. Greenhouse gas emissions are enhanced by wastewater discharge into New York City coastal estuaries

    NASA Astrophysics Data System (ADS)

    Brigham, B. A.; O'Mullan, G. D.; Bird, J. A.

    2016-12-01

    The Hudson River Estuary (HRE) receives significant inputs of untreated wastewater from sewer overflow from New York City (NYC) and other urban areas. These inputs deliver large, concentrated pulses of carbon (C) and nitrogen (N) into the estuary primarily during storm events. We hypothesized that sewage inputs would increase carbon dioxide (CO2) and methane (CH4) efflux from the HRE via two mechanism: (1) direct input of these gases into estuarine surface waters from NYC's wastewater treatment system; and (2) indirect in-situ microbial production in response to the C and N additions. To test these hypotheses, CO2, CH4, dissolved organic C and inorganic N concentrations were measured in both sewage outflow and in estuarine waters. Efflux of CO2 and CH4 were also quantified from sediment cores sampled from Flushing Bay (FB), which is in close proximity to sewage delivery outlets. Wastewater discharge was found to be both a direct input in wastewater and an indirect source of CO2 and CH4 via microbial respiration. Effluent concentrations of CH4 (125 ppm), CO2 (2200 ρCO2), dissolved organic C, ammonium, and nitrate surface water concentrations, were a minimum of 3 times greater than in estuarine surface water adjacent to the sewage delivery area and up to 20 times greater than concentrations found in regional HRE surface waters. Incubation experiments with FB sediment demonstrated that acetate additions stimulated CO2 efflux by + 1.25 and CH4 efflux by +10 times, compared with unamended controls. The magnitude of CH4 produced was +40 times greater than from sediments incubated from a non-sewage affected area with similar salinity levels. However, total C mineralization (6 µg C day-1 g-1 of dry soil) was a small portion of the C amendment indicating negligible priming. These data warrant study on larger regional scales to assess the broader climate impact likely driven by CH4 efflux that results from discharge of untreated wastewater into urban estuaries.

  12. Spatial accessibility to physical activity facilities and to food outlets and overweight in French youth

    PubMed Central

    Casey, R; Chaix, B; Weber, C; Schweitzer, B; Charreire, H; Salze, P; Badariotti, D; Banos, A; Oppert, J-M; Simon, C

    2012-01-01

    Objective: Some characteristics of the built environment have been associated with obesity in youth. Our aim was to determine whether individual and environmental socio-economic characteristics modulate the relation between youth overweight and spatial accessibility to physical activity (PA) facilities and to food outlets. Design: Cross-sectional study. Subjects: 3293 students, aged 12±0.6 years, randomly selected from eastern France middle schools. Measurements and methods: Using geographical information systems (GIS), spatial accessibility to PA facilities (urban and nature) was assessed using the distance to PA facilities at the municipality level; spatial accessibility to food outlets (general food outlets, bakeries and fast-food outlets) was calculated at individual level using the student home address and the food outlets addresses. Relations of weight status with spatial accessibility to PA facilities and to food outlets were analysed using mixed logistic models, testing potential direct and interaction effects of individual and environmental socio-economic characteristics. Results: Individual socio-economic status modulated the relation between spatial accessibility to PA facilities and to general food outlets and overweight. The likelihood of being overweight was higher when spatial accessibility to urban PA facilities and to general food outlets was low, but in children of blue-collar-workers only. The odds ratio (OR) (95% confidence interval) for being overweight of blue-collar-workers children compared with non-blue-collar-workers children was 1.76 (1.25–2.49) when spatial accessibility to urban PA facilities was low. This OR was 1.86 (1.20–2.86) when spatial accessibility to general food outlets was low. There was no significant relationship of overweight with either nature PA facilities or other food outlets (bakeries and fast-food outlets). Conclusion: These results indicate that disparities in spatial accessibility to PA facilities and to

  13. Spatial accessibility to physical activity facilities and to food outlets and overweight in French youth.

    PubMed

    Casey, R; Chaix, B; Weber, C; Schweitzer, B; Charreire, H; Salze, P; Badariotti, D; Banos, A; Oppert, J-M; Simon, C

    2012-07-01

    Some characteristics of the built environment have been associated with obesity in youth. Our aim was to determine whether individual and environmental socio-economic characteristics modulate the relation between youth overweight and spatial accessibility to physical activity (PA) facilities and to food outlets. Cross-sectional study. 3293 students, aged 12 ± 0.6 years, randomly selected from eastern France middle schools. Using geographical information systems (GIS), spatial accessibility to PA facilities (urban and nature) was assessed using the distance to PA facilities at the municipality level; spatial accessibility to food outlets (general food outlets, bakeries and fast-food outlets) was calculated at individual level using the student home address and the food outlets addresses. Relations of weight status with spatial accessibility to PA facilities and to food outlets were analysed using mixed logistic models, testing potential direct and interaction effects of individual and environmental socio-economic characteristics. Individual socio-economic status modulated the relation between spatial accessibility to PA facilities and to general food outlets and overweight. The likelihood of being overweight was higher when spatial accessibility to urban PA facilities and to general food outlets was low, but in children of blue-collar-workers only. The odds ratio (OR) (95% confidence interval) for being overweight of blue-collar-workers children compared with non-blue-collar-workers children was 1.76 (1.25-2.49) when spatial accessibility to urban PA facilities was low. This OR was 1.86 (1.20-2.86) when spatial accessibility to general food outlets was low. There was no significant relationship of overweight with either nature PA facilities or other food outlets (bakeries and fast-food outlets). These results indicate that disparities in spatial accessibility to PA facilities and to general food outlets may amplify the risk of overweight in socio

  14. Seasonal and temporal variation in release of antibiotics in hospital wastewater: estimation using continuous and grab sampling.

    PubMed

    Diwan, Vishal; Stålsby Lundborg, Cecilia; Tamhankar, Ashok J

    2013-01-01

    The presence of antibiotics in the environment and their subsequent impact on resistance development has raised concerns globally. Hospitals are a major source of antibiotics released into the environment. To reduce these residues, research to improve knowledge of the dynamics of antibiotic release from hospitals is essential. Therefore, we undertook a study to estimate seasonal and temporal variation in antibiotic release from two hospitals in India over a period of two years. For this, 6 sampling sessions of 24 hours each were conducted in the three prominent seasons of India, at all wastewater outlets of the two hospitals, using continuous and grab sampling methods. An in-house wastewater sampler was designed for continuous sampling. Eight antibiotics from four major antibiotic groups were selected for the study. To understand the temporal pattern of antibiotic release, each of the 24-hour sessions were divided in three sub-sampling sessions of 8 hours each. Solid phase extraction followed by liquid chromatography/tandem mass spectrometry (LC-MS/MS) was used to determine the antibiotic residues. Six of the eight antibiotics studied were detected in the wastewater samples. Both continuous and grab sampling methods indicated that the highest quantities of fluoroquinolones were released in winter followed by the rainy season and the summer. No temporal pattern in antibiotic release was detected. In general, in a common timeframe, continuous sampling showed less concentration of antibiotics in wastewater as compared to grab sampling. It is suggested that continuous sampling should be the method of choice as grab sampling gives erroneous results, it being indicative of the quantities of antibiotics present in wastewater only at the time of sampling. Based on our studies, calculations indicate that from hospitals in India, an estimated 89, 1 and 25 ng/L/day of fluroquinolones, metronidazole and sulfamethoxazole respectively, might be getting released into the

  15. Cold climate performance analysis of on-site domestic wastewater treatment systems.

    PubMed

    Williamson, Eric

    2010-06-01

    Household on-site septic systems with secondary wastewater treatment in Anchorage, Alaska, were sampled and analyzed for performance parameters during the winter to spring months. System types included intermittent dosing sand filters (ISF), three types of recirculating trickling filters (RTF), and suspended-growth aeration tanks. Total nitrogen from the trickling filter and aeration tank effluent was fairly uniform, at approximately 30 mg/L. Total suspended solids (TSS) means were mostly less than 15 mg/L. The 5-day biochemical oxygen demand (BODs) showed considerable variability, with means ranging from 9.2 mg/ L for ISFs up to 39.5 mg/L for one type of RTF, even though this type has shown excellent results in several test programs. The data suggested that effluent temperature within the sample range had almost no effect on effluent concentrations of BOD5 or TSS and only a small effect on the removal of total nitrogen. Non-climatic factors were probably of equal importance to treatment results.

  16. Methods for implementing a medicine outlet survey: lessons from the anti-malarial market.

    PubMed

    O'Connell, Kathryn A; Poyer, Stephen; Solomon, Tsione; Munroe, Erik; Patouillard, Edith; Njogu, Julius; Evance, Illah; Hanson, Kara; Shewchuk, Tanya; Goodman, Catherine

    2013-02-05

    In recent years an increasing number of public investments and policy changes have been made to improve the availability, affordability and quality of medicines available to consumers in developing countries, including anti-malarials. It is important to monitor the extent to which these interventions are successful in achieving their aims using quantitative data on the supply side of the market. There are a number of challenges related to studying supply, including outlet sampling, gaining provider cooperation and collecting accurate data on medicines. This paper provides guidance on key steps to address these issues when conducting a medicine outlet survey in a developing country context. While the basic principles of good survey design and implementation are important for all surveys, there are a set of specific issues that should be considered when conducting a medicine outlet survey. This paper draws on the authors' experience of designing and implementing outlet surveys, including the lessons learnt from ACTwatch outlet surveys on anti-malarial retail supply, and other key studies in the field. Key lessons and points of debate are distilled around the following areas: selecting a sample of outlets; techniques for collecting and analysing data on medicine availability, price and sales volumes; and methods for ensuring high quality data in general. The authors first consider the inclusion criteria for outlets, contrasting comprehensive versus more focused approaches. Methods for developing a reliable sampling frame of outlets are then presented, including use of existing lists, key informants and an outlet census. Specific issues in the collection of data on medicine prices and sales volumes are discussed; and approaches for generating comparable price and sales volume data across products using the adult equivalent treatment dose (AETD) are explored. The paper concludes with advice on practical considerations, including questionnaire design, field worker

  17. Alcohol Consumption, Alcohol Outlets, and the Risk of Being Assaulted With a Gun

    PubMed Central

    Branas, Charles C.; Elliott, Michael R.; Richmond, Therese S.; Culhane, Dennis P.; Wiebe, Douglas J.

    2010-01-01

    Background We conducted a population-based case–control study to better delineate the relationship between individual alcohol consumption, alcohol outlets in the surrounding environment, and being assaulted with a gun. Methods An incidence density sampled case–control study was conducted in the entire city of Philadelphia from 2003 to 2006. We enrolled 677 cases that had been shot in an assault and 684 population-based controls. The relationships between 2 independent variables of interest, alcohol consumption and alcohol outlet availability, and the outcome of being assaulted with a gun were analyzed. Conditional logistic regression was used to adjust for numerous confounding variables. Results After adjustment, heavy drinkers were 2.67 times as likely to be shot in an assault when compared with nondrinkers (p < 0.10) while light drinkers were not at significantly greater risk of being shot in an assault when compared with nondrinkers. Regression-adjusted analyses also demonstrated that being in an area of high off-premise alcohol outlet availability significantly increased the risk of being shot in an assault by 2.00 times (p < 0.05). Being in an area of high on-premise alcohol outlet availability did not significantly change this risk. Heavy drinkers in areas of high off-premise alcohol outlet availability were 9.34 times (p < 0.05) as likely to be shot in an assault. Conclusions This study finds that the gun assault risk to individuals who are near off-premise alcohol outlets is about the same as or statistically greater than the risk they incur from heavy drinking. The combination of heavy drinking and being near off-premise outlets resulted in greater risk than either factor alone. By comparison, light drinking and being near on-premise alcohol outlets were not associated with increased risks for gun assault. Cities should consider addressing alcohol-related factors, especially off-premise outlets, as highly modifiable and politically feasible approaches

  18. Spatial-temporal distribution and potential ecological risk assessment of nonylphenol and octylphenol in riverine outlets of Pearl River Delta, China.

    PubMed

    Chen, Ru; Yin, Pinghe; Zhao, Ling; Yu, Qiming; Hong, Aihua; Duan, Shunshan

    2014-11-01

    The aquatic environments of the Pearl River Delta in Southern China are subjected to contamination with various industrial chemicals from local industries. In this paper, the occurrence, seasonal variation and spatial distribution of alkylphenol octylphenol (OP) and nonylphenol (NP) in river surface water and sediments in the runoff outlets of the Pearl River Delta were investigated. NP and OP were detected in all water and sediment samples and their mean concentrations in surface water during the dry season ranged from 810 to 3366 ng/L and 85.5 to 581 ng/L, respectively, and those in sediments ranged from 14.2 to 95.2 ng/g dw and 0.4 to 3.0 ng/g dw, respectively. In surface water, much higher concentrations were detected in the dry season than those in the wet season. In sediments, the concentrations in the dry season were also mostly higher. High concentrations of NP and OP were found in Humen outlet, likely due to high levels of domestic and industrial wastewater discharges. An ecological risk assessment with the use of hazard quotient (HQ) was also carried out and the HQ values ranged from 3.6×10(-5) to 35 and 64% of samples gave a HQ>1, indicating that the current levels of NP and OP pose a significant risk to the relevant aquatic organisms in the region. Copyright © 2014. Published by Elsevier B.V.

  19. Deterioration to extinction of wastewater bacteria by non-thermal atmospheric pressure air plasma as assessed by 16S rDNA-DGGE fingerprinting

    PubMed Central

    El-Sayed, Wael S.; Ouf, Salama A.; Mohamed, Abdel-Aleam H.

    2015-01-01

    The use of cold plasma jets for inactivation of a variety of microorganisms has recently been evaluated via culture-based methods. Accordingly, elucidation of the role of cold plasma in decontamination would be inaccurate because most microbial populations within a system remain unexplored owing to the high amount of yet uncultured bacteria. The impact of cold atmospheric plasma on the bacterial community structure of wastewater from two different industries was investigated by metagenomic-based polymerase chain reaction-denaturing gradient gel electrophoresis (DGGE) utilizing 16S rRNA genes. Three doses of atmospheric pressure dielectric barrier discharge plasma were applied to wastewater samples on different time scales. DGGE revealed that the bacterial community gradually changed and overall abundance decreased to extinction upon plasma treatment. The bacterial community in food processing wastewater contained 11 key operational taxonomic units that remained almost completely unchanged when exposed to plasma irradiation at 75.5 mA for 30 or 60 s. However, when exposure time was extended to 90 s, only Escherichia coli, Coliforms, Aeromonas sp., Vibrio sp., and Pseudomonas putida survived. Only E. coli, Aeromonas sp., Vibrio sp., and P. putida survived treatment at 81.94 mA for 90 s. Conversely, all bacterial groups were completely eliminated by treatment at 85.34 mA for either 60 or 90 s. Dominant bacterial groups in leather processing wastewater also changed greatly upon exposure to plasma at 75.5 mA for 30 or 60 s, with Enterobacter aerogenes, Klebsiella sp., Pseudomonas stutzeri, and Acidithiobacillus ferrooxidans being sensitive to and eliminated from the community. At 90 s of exposure, all groups were affected except for Pseudomonas sp. and Citrobacter freundii. The same trend was observed for treatment at 81.94 mA. The variability in bacterial community response to different plasma treatment protocols revealed that plasma had a selective impact on bacterial

  20. The roles of outlet density and norms in alcohol use disorder.

    PubMed

    Ahern, Jennifer; Balzer, Laura; Galea, Sandro

    2015-06-01

    Alcohol outlet density and norms shape alcohol consumption. However, due to analytic challenges we do not know: (a) if alcohol outlet density and norms also shape alcohol use disorder, and (b) whether they act in combination to shape disorder. We applied a new targeted minimum loss-based estimator for rare outcomes (rTMLE) to a general population sample from New York City (N = 4000) to examine the separate and combined relations of neighborhood alcohol outlet density and norms around drunkenness with alcohol use disorder. Alcohol use disorder was assessed using the World Mental Health Comprehensive International Diagnostic Interview (WMH-CIDI) alcohol module. Confounders included demographic and socioeconomic characteristics, as well as history of drinking prior to residence in the current neighborhood. Alcohol use disorder prevalence was 1.78%. We found a marginal risk difference for alcohol outlet density of 0.88% (95% CI 0.00-1.77%), and for norms of 2.05% (95% CI 0.89-3.21%), adjusted for confounders. While each exposure had a substantial relation with alcohol use disorder, there was no evidence of additive interaction between the exposures. Results indicate that the neighborhood environment shapes alcohol use disorder. Despite the lack of additive interaction, each exposure had a substantial relation with alcohol use disorder and our findings suggest that alteration of outlet density and norms together would likely be more effective than either one alone. Important next steps include development and testing of multi-component intervention approaches aiming to modify alcohol outlet density and norms toward reducing alcohol use disorder. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  1. Uncertainty in measuring runoff from small watersheds using instrumented outlet-pond

    USDA-ARS?s Scientific Manuscript database

    This study quantified the uncertainty associated with event runoff quantity monitored at watershed outlet ponds. Inflow and outflow depth data were collected from 2004 to 2011 at seven instrumented monitoring stations at the outlet of watersheds ranging in size from 35.2 to 159.5 ha on the USDA-ARS ...

  2. 46 CFR 108.453 - Discharge outlets.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Discharge outlets. 108.453 Section 108.453 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems Fixed Carbon Dioxide Fire Extinguishing Systems § 108.453 Discharge...

  3. 46 CFR 108.453 - Discharge outlets.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Discharge outlets. 108.453 Section 108.453 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems Fixed Carbon Dioxide Fire Extinguishing Systems § 108.453 Discharge...

  4. Understanding private retail drug outlet dispenser knowledge and practices in tuberculosis care in Tanzania.

    PubMed

    Rutta, E; Tarimo, A; Delmotte, E; James, I; Mwakisu, S; Kasembe, D; Konduri, N; Silumbe, R; Kakanda, K; Valimba, R

    2014-09-01

    Private sector accredited drug dispensing outlets in Morogoro and pharmacies in Dar es Salaam, Tanzania. To assess 1) the level of knowledge about tuberculosis (TB) among dispensers in Tanzania's retail pharmaceutical sector; 2) practices related to identification of patients with suspected TB; 3) the availability of educational materials and training; and 4) the availability of first- and second-line anti-tuberculosis treatment in retail drug outlets. A cross-sectional descriptive study involving the administration of a structured questionnaire among drug dispensers in 122 pharmacies and 173 accredited drug dispensing outlets. Private retail drug outlets are convenient; most are open at least 12 h per day, 7 days/week. Although 95% of dispensers identified persistent cough as a symptom of TB, only 1% had received TB-related training in the previous 3 years; 8% of outlets stocked first-line anti-tuberculosis medicines, which are legally prohibited from being sold at retail outlets. The majority of respondents reported seeing clients with TB-like symptoms, and of these 95% reported frequently referring clients to nearby health facilities. Private retail pharmaceutical outlets can potentially contribute to TB case detection and treatment; however, a coordinated effort is needed to train dispensers and implement appropriate referral procedures.

  5. Beyond supermarkets: Food outlet location selection in four U.S. cities over time

    PubMed Central

    Rummo, Pasquale E.; Guilkey, David K.; Ng, Shu Wen; Popkin, Barry M.; Evenson, Kelly R.; Gordon-Larsen, P.

    2017-01-01

    Introduction Understanding what influences where food outlets locate is important for mitigating disparities in access to healthy food outlets. However, few studies have examined how neighborhood characteristics influence the neighborhood food environment over time, and whether these relationships differ by neighborhood-level income. Methods Neighborhood-level data from four U.S. cities (Birmingham, AL; Chicago, IL; Minneapolis, MN; Oakland, CA) from 1986, 1993, 1996, 2001, 2006, and 2011 were used with two-step econometric models to estimate longitudinal associations between neighborhood-level characteristics (z-scores) and the log-transformed count/km2 (density) of food outlets within real-estate-derived neighborhoods. We examined associations with lagged neighborhood-level sociodemographics and lagged density of food outlets, with interaction terms for neighborhood-level income. Data were analyzed in 2016. Results Neighborhood-level income at earlier years was negatively associated with the current density of convenience stores (β= −0.27; 95% CI: −0.16, −0.38; p<0.001). The percentage of neighborhood white population was negatively associated with fast food restaurant density in low income neighborhoods (10th percentile of income: β= −0.17; 95% CI: −0.34, −0.002; p=0.05), and the density of smaller grocery stores across all income levels (β= −0.27; 95% CI: −0.45, −0.09; p=0.003). There was a lack of policy-relevant associations between the pre-existing food environment and the current density of food outlet types, including supermarkets. Conclusions Socioeconomically-disadvantaged populations and minority populations may attract ‘unhealthy’ food outlets over time. To support equal access to healthy food outlets, the availability of ‘less healthy’ food outlets types may be relatively more important than the potential lack of supermarkets or full-service restaurants. PMID:27865651

  6. Beyond Supermarkets: Food Outlet Location Selection in Four U.S. Cities Over Time.

    PubMed

    Rummo, Pasquale E; Guilkey, David K; Ng, Shu Wen; Popkin, Barry M; Evenson, Kelly R; Gordon-Larsen, Penny

    2017-03-01

    Understanding what influences where food outlets locate is important for mitigating disparities in access to healthy food outlets. However, few studies have examined how neighborhood characteristics influence the neighborhood food environment over time, and whether these relationships differ by neighborhood-level income. Neighborhood-level data from four U.S. cities (Birmingham, AL; Chicago, IL; Minneapolis, MN; Oakland, CA) from 1986, 1993, 1996, 2001, 2006, and 2011 were used with two-step econometric models to estimate longitudinal associations between neighborhood-level characteristics (z-scores) and the log-transformed count/km 2 (density) of food outlets within real estate-derived neighborhoods. Associations were examined with lagged neighborhood-level sociodemographics and lagged density of food outlets, with interaction terms for neighborhood-level income. Data were analyzed in 2016. Neighborhood-level income at earlier years was negatively associated with the current density of convenience stores (β= -0.27, 95% CI= -0.16, -0.38, p<0.001). The percentage of neighborhood white population was negatively associated with fast food restaurant density in low-income neighborhoods (10th percentile of income: β= -0.17, 95% CI= -0.34, -0.002, p=0.05), and the density of smaller grocery stores across all income levels (β= -0.27, 95% CI= -0.45, -0.09, p=0.003). There was a lack of policy-relevant associations between the pre-existing food environment and the current density of food outlet types, including supermarkets. Socioeconomically disadvantaged and minority populations may attract "unhealthy" food outlets over time. To support equal access to healthy food outlets, the availability of "less healthy" food outlets types may be relatively more important than the potential lack of supermarkets or full-service restaurants. Copyright © 2016 American Journal of Preventive Medicine. Published by Elsevier Inc. All rights reserved.

  7. Using ZIP Code Business Patterns Data to Measure Alcohol Outlet Density

    PubMed Central

    Matthews, Stephen A.; McCarthy, John D.; Rafail, Patrick S.

    2014-01-01

    Some states maintain high-quality alcohol outlet databases but quality varies by state, making comprehensive comparative analysis across US communities difficult. This study assesses the adequacy of using ZIP Code Business Patterns (ZIP-BP) data on establishments as estimates of the number of alcohol outlets by ZIP code. Specifically we compare ZIP-BP alcohol outlet counts with high-quality data from state and local records surrounding 44 college campus communities across 10 states plus the District of Columbia. Results show that a composite measure is strongly correlated (R=0.89) with counts of alcohol outlets generated from official state records. Analyses based on Generalized Estimation Equation models show that community and contextual factors have little impact on the concordance between the two data sources. There are also minimal inter-state differences in the level of agreement. To validate the use of a convenient secondary data set (ZIP-BP) it is important to have a high correlation with the more complex, high quality and more costly data product (i.e., datasets based on the acquisition and geocoding of state and local records) and then to clearly demonstrate that the discrepancy between the two to be unrelated to relevant explanatory variables. Thus our overall findings support the adequacy of using a conveniently available data set (ZIP-BP data) to estimate alcohol outlet densities in ZIP code areas in future research. PMID:21411233

  8. Tobacco outlet density near home and school: Associations with smoking and norms among US teens

    PubMed Central

    Schleicher, Nina C.; Johnson, Trent O.; Fortmann, Stephen P.; Henriksen, Lisa

    2016-01-01

    This study examined whether living or going to school in neighborhoods with higher tobacco outlet density is associated with higher odds of cigarette smoking among teens, and with perceptions of greater smoking prevalence and peer approval. Using an Internet panel that is representative of US households, we matched data from teen-parent pairs (n=2,771, surveyed June 2011– December 2012) with environmental data about home and school neighborhoods. Density was measured as the number of tobacco outlets per square mile for a ½-mile roadway service area around each participant’s home and school. Logistic regressions tested relationships between tobacco outlet density near home and schools with ever smoking. Linear regressions tested relationships between density, perceived prevalence and peer approval. Models were adjusted for teen, parent/household and neighborhood characteristics. In total, 41.0% of US teens (ages 13–16) lived within ½ mile of a tobacco outlet, and 44.4% attended school within 1,000 feet of a tobacco outlet. Higher tobacco outlet density near home was associated with higher odds of ever smoking, although the relationship was small, OR=1.01, 95% CI (1.00,1.02). Higher tobacco outlet density near home was also associated with perceptions that more adults smoked, coef.=0.09, 95% CI (0.01,0.17). Higher tobacco outlet density near schools was not associated with any outcomes. Living in neighborhoods with higher tobacco outlet density may contribute to teen smoking by increasing access to tobacco products and by cultivating perceptions that smoking is more prevalent. Policy interventions to restrict tobacco outlet density should not be limited to school environments. PMID:27569829

  9. Tobacco outlet density near home and school: Associations with smoking and norms among US teens.

    PubMed

    Schleicher, Nina C; Johnson, Trent O; Fortmann, Stephen P; Henriksen, Lisa

    2016-10-01

    This study examined whether living or going to school in neighborhoods with higher tobacco outlet density is associated with higher odds of cigarette smoking among teens, and with perceptions of greater smoking prevalence and peer approval. Using an Internet panel that is representative of US households, we matched data from teen-parent pairs (n=2771, surveyed June 2011-December 2012) with environmental data about home and school neighborhoods. Density was measured as the number of tobacco outlets per square mile for a ½-mile roadway service area around each participant's home and school. Logistic regressions tested relationships between tobacco outlet density near home and schools with ever smoking. Linear regressions tested relationships between density, perceived prevalence and peer approval. Models were adjusted for teen, parent/household and neighborhood characteristics. In total, 41.0% of US teens (ages 13-16) lived within ½ mile of a tobacco outlet, and 44.4% attended school within 1000ft of a tobacco outlet. Higher tobacco outlet density near home was associated with higher odds of ever smoking, although the relationship was small, OR=1.01, 95% CI (1.00, 1.02). Higher tobacco outlet density near home was also associated with perceptions that more adults smoked, coef.=0.09, 95% CI (0.01, 0.17). Higher tobacco outlet density near schools was not associated with any outcomes. Living in neighborhoods with higher tobacco outlet density may contribute to teen smoking by increasing access to tobacco products and by cultivating perceptions that smoking is more prevalent. Policy interventions to restrict tobacco outlet density should not be limited to school environments. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Socio-Spatial Patterning of Off-Sale and On-Sale Alcohol Outlets in a Texas City

    PubMed Central

    Han, Daikwon; Gorman, Dennis M.

    2014-01-01

    Introduction and Aims To examine the socio-spatial patterning of off-sale and on-sale alcohol outlets following a policy change that ended prohibition of off-sale outlets in Lubbock, Texas. Design and Methods The spatial patterning of alcohol outlets by licensing type was examined using the k-function difference (D statistic) to compare the relative degree of spatial aggregation of the two types of alcohol outlets and by the spatial scan statistic to identify statistically significant geographic clusters of outlets. The sociodemographic characteristics of the areas containing clusters of outlets were compared to the rest of the city. In addition, the socioeconomic characteristics of census block groups with and without existing on-sale outlets were compared, as were the socioeconomic characteristics of census block groups with and without the newly issued off-sale licenses. Results The existing on-sale premises in Lubbock and the newly established off-sale premises introduced as a result of the 2009 policy change displayed different spatial patterns, with the latter being more spatially dispersed. A large cluster of on-sale outlets identified in the north-east of the city was located in a socially and economically disadvantaged area of the city. Discussion and Conclusion The findings support the view that it is important to understand the local context of deprivation within a city when examining the location of alcohol outlets and add to the existing research by drawing attention to the importance of geographic scale in assessing such relationships. PMID:24320205

  11. Socio-spatial patterning of off-sale and on-sale alcohol outlets in a Texas city.

    PubMed

    Han, Daikwon; Gorman, Dennis M

    2014-03-01

    To examine the socio-spatial patterning of off-sale and on-sale alcohol outlets following a policy change that ended prohibition of off-sale outlets in Lubbock, Texas. The spatial patterning of alcohol outlets by licensing type was examined using the k-function difference (D statistic) to compare the relative degree of spatial aggregation of the two types of alcohol outlets and by the spatial scan statistic to identify statistically significant geographic clusters of outlets. The sociodemographic characteristics of the areas containing clusters of outlets were compared with the rest of the city. In addition, the socioeconomic characteristics of census block groups with and without existing on-sale outlets were compared, as were the socioeconomic characteristics of census block groups with and without the newly issued off-sale licenses. The existing on-sale premises in Lubbock and the newly established off-sale premises introduced as a result of the 2009 policy change displayed different spatial patterns, with the latter being more spatially dispersed. A large cluster of on-sale outlets identified in the north-east of the city was located in a socially and economically disadvantaged area of the city. The findings support the view that it is important to understand the local context of deprivation within a city when examining the location of alcohol outlets and add to the existing research by drawing attention to the importance of geographic scale in assessing such relationships. © 2013 Australasian Professional Society on Alcohol and other Drugs.

  12. Is local alcohol outlet density related to alcohol-related morbidity and mortality in Scottish cities?

    PubMed Central

    Richardson, E.A.; Hill, S.E.; Mitchell, R.; Pearce, J.; Shortt, N.K.

    2015-01-01

    Alcohol consumption may be influenced by the local alcohol retailing environment. This study is the first to examine neighbourhood alcohol outlet availability (on- and off-sales outlets) and alcohol-related health outcomes in Scotland. Alcohol-related hospitalisations and deaths were significantly higher in neighbourhoods with higher outlet densities, and off-sales outlets were more important than on-sales outlets. The relationships held for most age groups, including those under the legal minimum drinking age, although were not significant for the youngest legal drinkers (18–25 years). Alcohol-related deaths and hospitalisations were higher in more income-deprived neighbourhoods, and the gradient in deaths (but not hospitalisations) was marginally larger in neighbourhoods with higher off-sales outlet densities. Efforts to reduce alcohol-related harm should consider the potentially important role of the alcohol retail environment. PMID:25840352

  13. Treating domestic effluent wastewater treatment by aerobic biofilter with bioballs medium

    NASA Astrophysics Data System (ADS)

    Permatasari, R.; Rinanti, A.; Ratnaningsih, R.

    2018-01-01

    This laboratory scale research aimed to treat wastewater effluent with advanced treatment utilizing aerobic biofilter with bio-balls medium to obtain effluent quality in accordance with DKI Jakarta Governor Regulation No. 122 of 2005. The seeding and acclimatization were conducted in 4 weeks. The effluent were accommodated in a 150 L water barrel supported by a submersible pump. The effluent were treated in two boxes shaped reactors made of glasses with 36 L of each capacity. These reactors were equipped with aquarium aerators, sampling tap is 10 cm from the base of reactors, and bio-balls with 3 cm diameter are made of PVC. Reactors operated continuously with variations of retention time of 4 hours, 8 hours, 12 hours, 18 hours, and 24 hours and also variations of Carbon: Nitrogen: Phosphor = C: N: P ratio were, 100:5:1, 100:8:1, 100:10:1, 100:12:1, 100:15:1. The results showed that the optimum variance of retention time was 24 hours and the ratio of C:N:P was 100:10:1 yielded the largest removal efficiency for 83,33% of COD, 87,33% of BOD, 82,5% of Ammonia, 79,1% of Nitrate, 92% of Nitrite, 84,82% of Oil and Grease. The concentration parameter resulted from outlet biofilter has met the domestic wastewater quality standard of DKI Jakarta.

  14. The association of alcohol outlet density with illegal underage adolescent purchasing of alcohol.

    PubMed

    Rowland, Bosco; Toumbourou, John W; Livingston, Michael

    2015-02-01

    Although previous studies have suggested that greater community densities of alcohol sales outlets are associated with greater alcohol use and problems, the mechanisms are unclear. The present study examined whether density was associated with increased purchasing of alcohol by adolescents younger than the legal purchase age of 18 in Australia. The number of alcohol outlets per 10,000 population was identified within geographic regions in Victoria, Australia. A state-representative student survey (N = 10,143) identified adolescent reports of purchasing alcohol, and multilevel modeling was then used to predict the effects for different densities of outlet types (packaged, club, on-premise, general, and overall). Each extra sales outlet per 10,000 population was associated with a significant increase in the risk of underage adolescent purchasing. The strongest effect was for club density (odds ratio = 1.22) and packaged (takeaway) outlet density (odds ratio = 1.12). Males, older children, smokers, and those with substance-using friends were more likely to purchase alcohol. One mechanism by which alcohol sales outlet density may influence population rates of alcohol use and related problems is through increasing the illegal underage purchasing of alcohol. Copyright © 2015 Society for Adolescent Health and Medicine. Published by Elsevier Inc. All rights reserved.

  15. Double-outlet right ventricle: Pathology and angiocardiography.

    PubMed

    Freedom, Robert M.; Yoo, Shi-Joon

    2000-01-01

    Double-outlet right ventricle is but one form of abnormal ventriculoarterial connection. The definition that more than half of each great artery originates above the morphologically right ventricle is arbitrary. As pointed out by Lecompte, those features that should be defined in hearts with the ventriculoarterial connection of double-outlet right ventricle (and indeed other forms of abnormal ventriculoarterial connection) include the nature of the infundibular septum, ventriculoinfundibular fold, trabeculoseptomargin-alis, attachments of infundibular septum to anterior or posterior limb of trabeculoseptomargin-alis, the size and position of the ventricular septal defect, the spatial relation of great artery(s) to the ventricular septal defect, the spatial relationship between the great, and the distance between the tricuspid and pulmonary valves and the semilunar valves. Copyright 2000 by W.B. Saunders Company

  16. 24 CFR 3280.806 - Receptacle outlets.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... appliances, be parallel-blade, 15-ampere, 125-volt, either single or duplex. (b) All 120 volt single phase... 24 Housing and Urban Development 5 2011-04-01 2011-04-01 false Receptacle outlets. 3280.806 Section 3280.806 Housing and Urban Development Regulations Relating to Housing and Urban Development...

  17. 24 CFR 3280.806 - Receptacle outlets.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... appliances, be parallel-blade, 15-ampere, 125-volt, either single or duplex. (b) All 120 volt single phase... 24 Housing and Urban Development 5 2013-04-01 2013-04-01 false Receptacle outlets. 3280.806 Section 3280.806 Housing and Urban Development Regulations Relating to Housing and Urban Development...

  18. 24 CFR 3280.806 - Receptacle outlets.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... appliances, be parallel-blade, 15-ampere, 125-volt, either single or duplex. (b) All 120 volt single phase... 24 Housing and Urban Development 5 2010-04-01 2010-04-01 false Receptacle outlets. 3280.806 Section 3280.806 Housing and Urban Development Regulations Relating to Housing and Urban Development...

  19. 24 CFR 3280.806 - Receptacle outlets.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... appliances, be parallel-blade, 15-ampere, 125-volt, either single or duplex. (b) All 120 volt single phase... 24 Housing and Urban Development 5 2012-04-01 2012-04-01 false Receptacle outlets. 3280.806 Section 3280.806 Housing and Urban Development Regulations Relating to Housing and Urban Development...

  20. Changes in density of on-premises alcohol outlets and impact on violent crime, Atlanta, Georgia, 1997-2007.

    PubMed

    Zhang, Xingyou; Hatcher, Bonnie; Clarkson, Lydia; Holt, James; Bagchi, Suparna; Kanny, Dafna; Brewer, Robert D

    2015-05-28

    Regulating alcohol outlet density is an evidence-based strategy for reducing excessive drinking. However, the effect of this strategy on violent crime has not been well characterized. A reduction in alcohol outlet density in the Buckhead neighborhood of Atlanta from 2003 through 2007 provided an opportunity to evaluate this effect. We conducted a community-based longitudinal study to evaluate the impact of changes in alcohol outlet density on violent crime in Buckhead compared with 2 other cluster areas in Atlanta (Midtown and Downtown) with high densities of alcohol outlets, from 1997 through 2002 (preintervention) to 2003 through 2007 (postintervention). The relationship between exposures to on-premises retail alcohol outlets and violent crime were assessed by using annual spatially defined indices at the census block level. Multilevel regression models were used to evaluate the relationship between changes in exposure to on-premises alcohol outlets and violent crime while controlling for potential census block-level confounders. A 3% relative reduction in alcohol outlet density in Buckhead from 1997-2002 to 2003-2007 was associated with a 2-fold greater reduction in exposure to violent crime than occurred in Midtown or Downtown, where exposure to on-premises retail alcohol outlets increased. The magnitude of the association between exposure to alcohol outlets and violent crime was 2 to 5 times greater in Buckhead than in either Midtown or Downtown during the postintervention period. A modest reduction in alcohol outlet density can substantially reduce exposure to violent crime in neighborhoods with high density of alcohol outlets. Routine monitoring of community exposure to alcohol outlets could also inform the regulation of alcohol outlet density, consistent with Guide to Community Preventive Services recommendations.

  1. Food prices, access to food outlets and child weight.

    PubMed

    Powell, Lisa M; Bao, Yanjun

    2009-03-01

    This study examines the importance of food prices and restaurant and food store outlet availability for child body mass index (BMI). We use the 1998, 2000 and 2002 waves of the child-mother merged files from the 1979 cohort of the National Longitudinal Survey of Youth combined with fruit and vegetable and fast food price data obtained from the American Chamber of Commerce Researchers Association and outlet density data on fast food and full-service restaurants and supermarkets, grocery stores and convenience stores obtained from Dun & Bradstreet. Using a random effects estimation model, we found that a 10% increase in the price of fruits and vegetables was associated with a 0.7% increase in child BMI. Fast food prices were not found to be statistically significant in the full sample but were weakly negatively associated with BMI among adolescents with an estimated price elasticity of -0.12. The price estimates were robust to whether we controlled for outlet availability based on a per capita or per land area basis; however, the association between food outlets and child BMI differed depending on the definition. The associations of fruit and vegetable and fast food prices with BMI were significantly stronger both economically and statistically among low- versus high-socioeconomic status children. The estimated fruit and vegetable and fast food price elasticities were 0.14 and -0.26, respectively, among low-income children and 0.09 and -0.13, respectively, among children with less educated mothers.

  2. Is local alcohol outlet density related to alcohol-related morbidity and mortality in Scottish cities?

    PubMed

    Richardson, E A; Hill, S E; Mitchell, R; Pearce, J; Shortt, N K

    2015-05-01

    Alcohol consumption may be influenced by the local alcohol retailing environment. This study is the first to examine neighbourhood alcohol outlet availability (on- and off-sales outlets) and alcohol-related health outcomes in Scotland. Alcohol-related hospitalisations and deaths were significantly higher in neighbourhoods with higher outlet densities, and off-sales outlets were more important than on-sales outlets. The relationships held for most age groups, including those under the legal minimum drinking age, although were not significant for the youngest legal drinkers (18-25 years). Alcohol-related deaths and hospitalisations were higher in more income-deprived neighbourhoods, and the gradient in deaths (but not hospitalisations) was marginally larger in neighbourhoods with higher off-sales outlet densities. Efforts to reduce alcohol-related harm should consider the potentially important role of the alcohol retail environment. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  3. The relationship between liquor outlet density and injury and violence in New Mexico.

    PubMed

    Escobedo, Luis G; Ortiz, Melchor

    2002-09-01

    This study used an ecologic design based on data from 1990 to 1994 gathered from forensic, vital statistic, census, law enforcement and liquor licensing agencies to assess the relationship between liquor outlet density and alcohol-related health outcomes in New Mexico. Linear regression models show that suicide, alcohol-related crash, and alcohol-related crash fatality (adjusted for age, sex, and minority status) are significantly associated with liquor outlet density. Data also show that, compared with the first tertile, suicide and alcohol-related crash rates increase about 50% and the alcohol-related crash fatality rate two-fold with the third tertile of liquor outlet density. Greater availability of liquor outlets is associated with higher rates of suicide, alcohol-related crash, and alcohol-related crash fatality.

  4. Using ZIP code business patterns data to measure alcohol outlet density.

    PubMed

    Matthews, Stephen A; McCarthy, John D; Rafail, Patrick S

    2011-07-01

    Some states maintain high-quality alcohol outlet databases but quality varies by state, making comprehensive comparative analysis across US communities difficult. This study assesses the adequacy of using ZIP Code Business Patterns (ZIP-BP) data on establishments as estimates of the number of alcohol outlets by ZIP code. Specifically we compare ZIP-BP alcohol outlet counts with high-quality data from state and local records surrounding 44 college campus communities across 10 states plus the District of Columbia. Results show that a composite measure is strongly correlated (R=0.89) with counts of alcohol outlets generated from official state records. Analyses based on Generalized Estimation Equation models show that community and contextual factors have little impact on the concordance between the two data sources. There are also minimal inter-state differences in the level of agreement. To validate the use of a convenient secondary data set (ZIP-BP) it is important to have a high correlation with the more complex, high quality and more costly data product (i.e., datasets based on the acquisition and geocoding of state and local records) and then to clearly demonstrate that the discrepancy between the two to be unrelated to relevant explanatory variables. Thus our overall findings support the adequacy of using a conveniently available data set (ZIP-BP data) to estimate alcohol outlet densities in ZIP code areas in future research. Copyright © 2011 Elsevier Ltd. All rights reserved.

  5. Sociodemographic Disparities in Proximity of Schools to Tobacco Outlets and Fast-Food Restaurants

    PubMed Central

    Ammerman, Alice; Gordon-Larsen, Penny; Linnan, Laura; Lytle, Leslie; Ribisl, Kurt M.

    2016-01-01

    Objectives. To examine the association of school sociodemographic characteristics with tobacco outlet and fast-food restaurant availability near schools in a national study. Methods. Business lists and data from the National Center for Education Statistics were used to calculate the numbers of tobacco outlets and fast-food restaurants within 800 meters of public schools in 97 US counties. Results. More than 50% of schools with a majority of Hispanic students had both a fast-food restaurant and tobacco outlet nearby, compared with 21% of schools with a majority of White students. In adjusted models, each 10% increase in the number of low-income and Hispanic students enrolled in a school led to a 3% to 5% increase in the odds of the school having both a fast-food restaurant and a tobacco outlet nearby. Conclusions. Low-income and Hispanic students are disproportionately exposed to both tobacco outlets and fast-food restaurants near their schools. Easy access to tobacco products and fast food may influence youth smoking initiation and contribute to poor dietary intake. PMID:27459453

  6. Sociodemographic Disparities in Proximity of Schools to Tobacco Outlets and Fast-Food Restaurants.

    PubMed

    D'Angelo, Heather; Ammerman, Alice; Gordon-Larsen, Penny; Linnan, Laura; Lytle, Leslie; Ribisl, Kurt M

    2016-09-01

    To examine the association of school sociodemographic characteristics with tobacco outlet and fast-food restaurant availability near schools in a national study. Business lists and data from the National Center for Education Statistics were used to calculate the numbers of tobacco outlets and fast-food restaurants within 800 meters of public schools in 97 US counties. More than 50% of schools with a majority of Hispanic students had both a fast-food restaurant and tobacco outlet nearby, compared with 21% of schools with a majority of White students. In adjusted models, each 10% increase in the number of low-income and Hispanic students enrolled in a school led to a 3% to 5% increase in the odds of the school having both a fast-food restaurant and a tobacco outlet nearby. Low-income and Hispanic students are disproportionately exposed to both tobacco outlets and fast-food restaurants near their schools. Easy access to tobacco products and fast food may influence youth smoking initiation and contribute to poor dietary intake.

  7. Validation of commercial business lists as a proxy for licensed alcohol outlets.

    PubMed

    Carlos, Heather A; Gabrielli, Joy; Sargent, James D

    2017-05-19

    Studies of retail alcohol outlets are restricted to regions due to lack of U.S. national data. Commercial business lists (BL) offer a possible solution, but no data exists to determine if BLs could serve as an adequate proxy for license data. This paper compares geospatial measures of alcohol outlets derived from a commercial BL with license data for a large US state. We validated BL data as a measure of off-premise alcohol outlet density and proximity compared to license data for 5528 randomly selected California residential addresses. We calculated three proximity measures (Euclidean distance, road network travel time and distance) and two density measures (kernel density estimation and the count within a 2-mile radius) for each dataset. The data was acquired in 2015 and processed and analyzed in 2015 and 2016. Correlations and reliabilities between density (correlation 0.98; Cronbach's α 0.97-0.99) and proximity (correlations 0.77-0.86; α 0.87-0.92) measures were high. For proximity, BL data matched license in 55-57% of addresses, overstated distance in 19%, and understated in 24-26%. BL data can serve as a reliable proxy for licensed alcohol outlets, thus extending the work that can be performed in studies on associations between retail alcohol outlets and drinking outcomes.

  8. Optimization of an integrated electrodisinfection/electrocoagulation process with Al bipolar electrodes for urban wastewater reclamation.

    PubMed

    Cotillas, Salvador; Llanos, Javier; Cañizares, Pablo; Mateo, Sara; Rodrigo, Manuel A

    2013-04-01

    In this work, a novel integrated electrochemical process for urban wastewater regeneration is described. The electrochemical cell consists in a Boron Doped Diamond (BDD) or a Dimensionally Stable Anode (DSA) as anode, a Stainless Steel (SS) as cathode and a perforated aluminum plate, which behaves as bipolar electrode, between anode and cathode. Thus, in this cell, it is possible to carry out, at the same time, two different electrochemical processes: electrodisinfection (ED) and electrocoagulation (EC). The treatment of urban wastewater with different anodes and different operating conditions is studied. First of all, in order to check the process performance, experiments with synthetic wastewaters were carried out, showing that it is possible to achieve a 100% of turbidity removal by the electrodissolution of the bipolar electrode. Next, the effect of the current density and the anode material are studied during the ED-EC process of actual effluents. Results show that it is possible to remove Escherichia coli and turbidity simultaneously of an actual effluent from a WasteWater Treatment Facility (WWTF). The use of BDD anodes allows to remove the E. coli completely at an applied electric charge of 0.0077 A h dm(-3) when working with a current density of 6.65 A m(-2). On the other hand, with DSA anodes, the current density necessary to achieve the total removal of E. coli is higher (11.12 A m(-2)) than that required with BDD anodes. Finally, the influence of cell flow path and flow rate have been studied. Results show that the performance of the process strongly depends on the characteristics of the initial effluent (E. coli concentration and Cl(-)/NH(4)(+) initial ratio) and that a cell configuration cathode (inlet)-anode (outlet) and a higher flow rate enhance the removal of the turbidity from the treated effluent. Copyright © 2013 Elsevier Ltd. All rights reserved.

  9. 14 CFR 27.977 - Fuel tank outlet.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... STANDARDS: NORMAL CATEGORY ROTORCRAFT Powerplant Fuel System § 27.977 Fuel tank outlet. (a) There must be a... rotorcraft, prevent the passage of any object that could restrict fuel flow or damage any fuel system...] Fuel System Components ...

  10. 14 CFR 27.977 - Fuel tank outlet.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... STANDARDS: NORMAL CATEGORY ROTORCRAFT Powerplant Fuel System § 27.977 Fuel tank outlet. (a) There must be a... rotorcraft, prevent the passage of any object that could restrict fuel flow or damage any fuel system...] Fuel System Components ...

  11. 14 CFR 27.977 - Fuel tank outlet.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... STANDARDS: NORMAL CATEGORY ROTORCRAFT Powerplant Fuel System § 27.977 Fuel tank outlet. (a) There must be a... rotorcraft, prevent the passage of any object that could restrict fuel flow or damage any fuel system...] Fuel System Components ...

  12. 14 CFR 27.977 - Fuel tank outlet.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... STANDARDS: NORMAL CATEGORY ROTORCRAFT Powerplant Fuel System § 27.977 Fuel tank outlet. (a) There must be a... rotorcraft, prevent the passage of any object that could restrict fuel flow or damage any fuel system...] Fuel System Components ...

  13. 14 CFR 27.977 - Fuel tank outlet.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... STANDARDS: NORMAL CATEGORY ROTORCRAFT Powerplant Fuel System § 27.977 Fuel tank outlet. (a) There must be a... rotorcraft, prevent the passage of any object that could restrict fuel flow or damage any fuel system...] Fuel System Components ...

  14. Pseudo-Underage Assessment of Compliance With Identification Regulations at Retail Marijuana Outlets in Colorado

    PubMed Central

    Buller, David B.; Woodall, W. Gill; Saltz, Robert; Starling, Randall

    2016-01-01

    Objective: Four states are creating a regulated industry for the retail sale of cannabis products. This pilot study assessed refusal rates of sales to underage-appearing individuals without valid identification (ID) at retail outlets in Colorado. Method: State-licensed retail marijuana outlets (n = 20) in Colorado were included in the sample. Pseudo-underage assessment teams of a buyer and an observer visited each retail outlet once between 11 a.m. and 5 p.m. on four weekdays in August 2015. The observer entered first, performed an unobtrusive environmental scan, and recorded the outcome of the purchase attempt. The buyer attempted to enter the outlet and purchase a cannabis product. If asked for an ID, they did not present one. Once inside, if the clerk offered to sell cannabis, the buyer declined, saying they had insufficient cash, and departed. Results: Most outlets sold both retail and medical marijuana (75%). All outlets (100%) asked the buyer to show an ID. Only one outlet was willing to sell marijuana to the pseudo-underage buyer after the buyer did not provide an ID (95% refusal rate). All outlets (100%) had posted signs stating that an ID was required for entry; approximately half had signs that only individuals 21 years of age or older could enter (55%) and how to properly use marijuana edibles (50%). Conclusions: Compliance with laws restricting marijuana sales to individuals age 21 years or older with a valid ID was extremely high and possibly higher than compliance with restrictions on alcohol sales. The retail market at present may not be a direct source of marijuana for underage individuals, but future research should investigate indirect sales. PMID:27797687

  15. The association between alcohol outlet accessibility and adverse birth outcomes: A retrospective cohort study.

    PubMed

    Seabrook, J A; Woods, N; Clark, A; de Vrijer, B; Penava, D; Gilliland, J

    2018-01-01

    Alcohol outlet accessibility is positively associated with alcohol consumption, although this relationship has not been thoroughly examined in pregnant women. The present study examines the relationship between proximity and density of alcohol outlets and risk for low birth weight (LBW: <2,500 grams) and preterm birth (PTB: <37 weeks gestational age), and is the first Canadian study to investigate this association. Maternal accessibility to alcohol outlets was specified using a gravity-type measure of accessibility, which provides the amount of accessibility that a given household has to liquor stores within 30-minutes of their home. All singleton newborns without congenital anomalies that were born between February 2009 and February 2014 at London Health Sciences Centre in London, Ontario, were included in this cohort. The sample consisted of 25,734 live births, of which 5.8% were LBW and 7.6% were PTB. Only 2.0% of women reported alcohol use during pregnancy. Alcohol outlet gravity was positively correlated with the percentage of mothers living in poverty (rs = 0.33, p < 0.001) and in single-parent families (rs = 0.39, p < 0.001), and who self-identify as visible minorities (rs = 0.45, p < 0.001). Alcohol outlet gravity increased the odds that mothers drank alcohol during pregnancy (OR 1.05; 95% CI: 1.02, 1.07), although the association was weak. Furthermore, alcohol outlet gravity did not increase the likelihood of a LBW or PTB infant. Women with high accessibility to alcohol outlets are more likely to consume alcohol during pregnancy, but greater alcohol outlet accessibility does not translate into poor birth outcomes.

  16. Pseudo-Underage Assessment of Compliance With Identification Regulations at Retail Marijuana Outlets in Colorado.

    PubMed

    Buller, David B; Woodall, W Gill; Saltz, Robert; Starling, Randall

    2016-11-01

    Four states are creating a regulated industry for the retail sale of cannabis products. This pilot study assessed refusal rates of sales to underage-appearing individuals without valid identification (ID) at retail outlets in Colorado. State-licensed retail marijuana outlets (n = 20) in Colorado were included in the sample. Pseudo-underage assessment teams of a buyer and an observer visited each retail outlet once between 11 A.M. and 5 P.M. on four weekdays in August 2015. The observer entered first, performed an unobtrusive environmental scan, and recorded the outcome of the purchase attempt. The buyer attempted to enter the outlet and purchase a cannabis product. If asked for an ID, they did not present one. Once inside, if the clerk offered to sell cannabis, the buyer declined, saying they had insufficient cash, and departed. Most outlets sold both retail and medical marijuana (75%). All outlets (100%) asked the buyer to show an ID. Only one outlet was willing to sell marijuana to the pseudo-underage buyer after the buyer did not provide an ID (95% refusal rate). All outlets (100%) had posted signs stating that an ID was required for entry; approximately half had signs that only individuals 21 years of age or older could enter (55%) and how to properly use marijuana edibles (50%). Compliance with laws restricting marijuana sales to individuals age 21 years or older with a valid ID was extremely high and possibly higher than compliance with restrictions on alcohol sales. The retail market at present may not be a direct source of marijuana for underage individuals, but future research should investigate indirect sales.

  17. Association Between Alcohol Use Among College Students and Alcohol Outlet Proximity and Densities.

    PubMed

    Tanumihardjo, Jacob; Shoff, Suzanne M; Koenings, Mallory; Zhang, Zhumin; Lai, HuiChuan J

    2015-08-01

    Alcohol consumption is common on college campuses and is associated with negative consequences. Factors associated with availability of alcohol are not completely understood. To describe how proximity and density of alcohol outlets are associated with any drinking and binge drinking in students at the University of Wisconsin-Madison. Participants were full-time students enrolled in the Young Adults Eating and Active for Health, a multisite, randomized intervention that assessed a variety of health behaviors. Geographic information systems were used to calculate proximity and enumerate alcohol outlet densities. Participants were categorized as "drinkers" or "nondrinkers" based on self-reported alcohol consumption. Binge drinking was categorized as "non-binge drinker," "frequent binge drinker," and "excessive binge drinker." Analysis included regression, t tests, and chi-square tests. RESULTS. Among the 166 participants, 126 (76%) were drinkers. Among drinkers, 80 (63%) were either frequent or excessive binge drinkers. Drinkers lived closer to an alcohol outlet than non-drinkers (0.18 +/- 0.15 vs. 0.61 +/- 1.59 miles, respectively, P=0.005). Within a 1-mile walking radius, there were 47% more establishments for drinkers (153 +/- 47 compared to 104 +/- 55 outlets for nondrinkers, P<0.0001). At distances of 0.10-0.25 and 0.25-0.50 miles, twice as many outlets were available to drinkers (19 +/- 19 and 43 +/- 25, respectively) compared to nondrinkers (7 +/- 11 and 20 +/- 22, respectively), P<0.001. Proximity and density were hot associated with binge drinking frequency. Drinkers lived closer to alcohol outlets and had significantly more outlets available at a distance of up to 1 mile. Municipal and college administrators could consider limiting alcohol license distributions in municipalities with high alcohol consumption.

  18. Shuttle Wastewater Solution Characterization

    NASA Technical Reports Server (NTRS)

    Adam, Niklas; Pham, Chau

    2011-01-01

    During the 31st shuttle mission to the International Space Station, STS-129, there was a clogging event in the shuttle wastewater tank. A routine wastewater dump was performed during the mission and before the dump was completed, degraded flow was observed. In order to complete the wastewater dump, flow had to be rerouted around the dump filter. As a result, a basic chemical and microbial investigation was performed to understand the shuttle wastewater system and perform mitigation tasks to prevent another blockage. Testing continued on the remaining shuttle flights wastewater and wastewater tank cleaning solutions. The results of the analyses and the effect of the mitigation steps are detailed in this paper.

  19. Proximity to Fast-Food Outlets and Supermarkets as Predictors of Fast-Food Dining Frequency.

    PubMed

    Athens, Jessica K; Duncan, Dustin T; Elbel, Brian

    2016-08-01

    This study used cross-sectional data to test the independent relationship of proximity to chain fast-food outlets and proximity to full-service supermarkets on the frequency of mealtime dining at fast-food outlets in two major urban areas, using three approaches to define access. Interactions between presence of a supermarket and presence of fast-food outlets as predictors of fast-food dining were also tested. Residential intersections for respondents in point-of-purchase and random-digit-dial telephone surveys of adults in Philadelphia, PA, and Baltimore, MD, were geocoded. The count of fast-food outlets and supermarkets within quarter-mile, half-mile, and 1-mile street network buffers around each respondent's intersection was calculated, as well as distance to the nearest fast-food outlet and supermarket. These variables were regressed on weekly fast-food dining frequency to determine whether proximity to fast food and supermarkets had independent and joint effects on fast-food dining. The effect of access to supermarkets and chain fast-food outlets varied by study population. Among telephone survey respondents, supermarket access was the only significant predictor of fast-food dining frequency. Point-of-purchase respondents were generally unaffected by proximity to either supermarkets or fast-food outlets. However, ≥1 fast-food outlet within a 1-mile buffer was an independent predictor of consuming more fast-food meals among point-of-purchase respondents. At the quarter-mile distance, ≥1 supermarket was predictive of fewer fast-food meals. Supermarket access was associated with less fast-food dining among telephone respondents, whereas access to fast-food outlets were associated with more fast-food visits among survey respondents identified at point-of-purchase. This study adds to the existing literature on geographic determinants of fast-food dining behavior among urban adults in the general population and those who regularly consume fast food. Copyright

  20. Endoscopic stenting versus operative gastrojejunostomy for malignant gastric outlet obstruction.

    PubMed

    Chandrasegaram, Manju D; Eslick, Guy D; Mansfield, Clare O; Liem, Han; Richardson, Mark; Ahmed, Sulman; Cox, Michael R

    2012-02-01

    Malignant gastric outlet obstruction represents a terminal stage in pancreatic cancer. Between 5% and 25% of patients with pancreatic cancer ultimately experience malignant gastric outlet obstruction. The aim in palliating patients with malignant gastric outlet obstruction is to reestablish an oral intake by restoring gastrointestinal continuity. This ultimately improves their quality of life in the advanced stages of cancer. The main drawback to operative bypass is the high incidence of delayed gastric emptying, particularly in this group of patients with symptomatic obstruction. This study aimed to compare surgical gastrojejunostomy and endoscopic stenting in palliation of malignant gastric outlet obstruction, acknowledging the diversity and heterogeneity of patients with this presentation. This retrospective study investigated patients treated for malignant gastric outlet obstruction from December 1998 to November 2008 at Nepean Hospital, Sydney, Australia. Endoscopic duodenal stenting was performed under fluoroscopic guidance for placement of the stent. The operative patients underwent open surgical gastrojejunostomy. The outcomes assessed included time to diet, hospital length of stay (LOS), biliary drainage procedures, morbidity, and mortality. Of the 45 participants in this study, 26 underwent duodenal stenting and 19 had operative bypass. Comparing the stenting and operative patients, the median time to fluid intake was respectively 0 vs. 7 days (P < 0.001), and the time to intake of solids was 2 vs. 9 days (P = 0.004). The median total LOS was shorter in the stenting group (11 vs. 25 days; P < 0.001), as was the median postprocedure LOS (5 vs. 10 days; P = 0.07). Endoscopic stenting is preferable to operative gastrojejunostomy in terms of shorter LOS, faster return to fluids and solids, and reduced morbidity and in-hospital mortality for patients with a limited life span.

  1. Patterning of neighbourhood food outlets and longitudinal associations with children's eating behaviours.

    PubMed

    Timperio, Anna; Crawford, David; Leech, Rebecca M; Lamb, Karen E; Ball, Kylie

    2018-06-01

    This study examined cross-sectional and prospective associations between typologies of neighbourhood food environment and dietary patterns among 10-12 year-old children. Baseline data were collected in 2003 and follow-up data in 2006 from children in Melbourne or Geelong. Parents completed a food frequency questionnaire at both time points. 'Healthful' and 'energy-dense' dietary pattern scores were computed. A Geographic Information System was used to determine the presence or absence of food outlets (cafés/restaurant; fast food; supermarkets/grocery stores; convenience store; greengrocer; and butcher, seafood or poultry retailer) within an 800 m road network buffer of home. Three typologies were identified: 1-variety of food outlets, including those selling core/fresh foods (n = 96); 2-café/restaurant and convenience (n = 160); 3-few types of outlets (n = 208). Latent class analysis was used to identify underlying unobservable typologies of neighbourhood food outlet availability. Linear mixed models were fitted to determine cross-sectional (n = 439) and longitudinal (n = 173) associations between the three identified neighbourhood typologies and each (log-transformed) dietary pattern, accounting for clustering within families and schools. There was little evidence of cross-sectional associations. The longitudinal analyses showed that compared to those with a variety of food outlets, those with few types had 25% lower scores for the healthful dietary pattern (p < 0.05) three years later. For optimal dietary patterns, availability of a variety of food outlets close to home, particularly those where core/fresh foods are available, may be important. Copyright © 2018 Elsevier Inc. All rights reserved.

  2. Tobacco outlet density and tobacco knowledge, beliefs, purchasing behaviours and price among adolescents in Scotland.

    PubMed

    Tunstall, Helena; Shortt, Niamh K; Niedzwiedz, Claire L; Richardson, Elizabeth A; Mitchell, Richard J; Pearce, Jamie R

    2018-06-01

    Despite long-term falls in global adult smoking prevalence and over 50 years of tobacco control policies, adolescent smoking persists. Research suggests greater densities of tobacco retail outlets in residential neighbourhoods are associated with higher adolescent smoking rates. Policies to reduce retail outlets have therefore been identified by public health researchers as a potential 'new frontier' in tobacco control. Better understanding of the pathways linking density of tobacco retailers and smoking behaviour could support these policies. In this study we use path analysis to assess how outlet density in the home environment is related to adolescent tobacco knowledge, beliefs, retail purchases and price in Scotland. We assessed 22,049 13 and 15 year old respondents to the nationally representative cross-sectional 2010 Scottish School Adolescent Lifestyle and Substance Use Survey. Outlet density was based on Scottish Tobacco Retailers Register, 2012, data. A spatially-weighted Kernel Density Estimation measure of outlet density within 400 m of respondents' home postcode was grouped into tertiles. The analysis considered whether outlet density was associated with the number of cigarette brands adolescents could name, positive beliefs about smoking, whether smokers purchased cigarettes from shops themselves or through adult proxies and perceived cost of cigarettes. Models were stratified by adolescent smoking status. The path analyses indicated that outlet density was not associated with most outcomes, but small, significant direct effects on knowledge of cigarette brands among those who had never smoked were observed. With each increase in outlet density tertile the mean number of brands adolescents could name rose by 0.07 (mean = 1.60; SD = 1.18; range = 4). This suggests greater outlet densities may have affected adolescents' knowledge of cigarette brands but did not encourage positive attitudes to smoking, purchases from shops or lower cigarette

  3. The inequitable distribution of tobacco outlet density: the role of income in two Black Mid-Atlantic geopolitical areas.

    PubMed

    Fakunle, D O; Milam, A J; Furr-Holden, C D; Butler, J; Thorpe, R J; LaVeist, T A

    2016-07-01

    Studies have shown that communities with higher concentrations of low-income racial and ethnic minorities correlate with a greater presence of tobacco outlets. Community-level income has consistently been among the strongest predictors of tobacco outlet density. This study analyzes two Maryland geopolitical areas with similar racial concentrations yet differing income levels in an attempt to disentangle the race-income relationship with tobacco outlet density. In this cross-sectional examination of tobacco outlet and census tract-level sociodemographic data, Baltimore City, Maryland, and Prince George's County, Maryland, were geocoded to determine tobacco outlet density. Tobacco outlet density was defined as the mean number of tobacco outlets per 1000 persons per census tract. Comparisons of tobacco outlet density and sociodemographic variables were analysed via two-sample t-tests, and the direct effect of sociodemographic variables on tobacco outlet density for each area was analysed via spatial lag regressions. Prince George's County, the area with the higher income level ($77,190 vs $43,571), has a significantly lower tobacco outlet density than Baltimore City (P < 0.001). Prince George's County has a 67.5% Black population and an average of 3.94 tobacco outlets per 1000 persons per tract. By contrast, Baltimore City has a 65.3% Black population and an average of 7.95 tobacco outlets per 1000 persons per tract. Spatial lag regression model results indicate an inverse relationship between income and tobacco outlet density in Baltimore City and Prince George's County (β = -0.03, P < 0.01 &β = -0.01, P = 0.02, respectively), and a significant interaction term indicating a greater magnitude in the relationship between income and tobacco outlet density in Baltimore City (β = -0.05, P < 0.01). Results suggest that higher socio-economic status, even in primarily underrepresented racial and ethnic geopolitical areas, is linked to lower tobacco outlet

  4. Assessing the feasibility of wastewater recycling and treatment efficiency of wastewater treatment units.

    PubMed

    Lou, Jie-Chung; Lin, Yung-Chang

    2008-02-01

    Wastewater reuse can significantly reduce environmental pollution and save the water sources. The study selected Cheng-Ching Lake water treatment plant in southern Taiwan to discuss the feasibility of wastewater recycling and treatment efficiency of wastewater treatment units. The treatment units of this plant include wastewater basin, sedimentation basin, sludge thickener and sludge dewatering facility. In this study, the treatment efficiency of SS and turbidity were 48.35-99.68% and 24.15-99.36%, respectively, showing the significant removal efficiency of the wastewater process. However, the removal efficiencies of NH(3)-N, total organic carbon (TOC) and chemical oxygen demand (COD) are limited by wastewater treatment processes. Because NH(3)-N, TOC and COD of the mixing supernatant and raw water are regulated raw water quality standards, supernatant reuse is feasible and workable during wastewater processes at this plant. Overall, analytical results indicated that supernatant reuse is feasible.

  5. 49 CFR 179.100-14 - Bottom outlets.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Transportation Other Regulations Relating to Transportation PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION HAZARDOUS MATERIALS REGULATIONS SPECIFICATIONS FOR TANK CARS Specifications for Pressure Tank Car Tanks (Classes DOT-105, 109, 112, 114 and 120) § 179.100-14 Bottom outlets...

  6. 49 CFR 179.103-5 - Bottom outlets.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Transportation Other Regulations Relating to Transportation PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION HAZARDOUS MATERIALS REGULATIONS SPECIFICATIONS FOR TANK CARS Specifications for Pressure Tank Car Tanks (Classes DOT-105, 109, 112, 114 and 120) § 179.103-5 Bottom outlets...

  7. Density of tobacco retail outlets near schools and smoking behaviour among secondary school students.

    PubMed

    Scully, Maree; McCarthy, Molly; Zacher, Meghan; Warne, Charles; Wakefield, Melanie; White, Victoria

    2013-12-01

    To investigate whether the density of tobacco retail outlets near schools in Victoria, Australia, is associated with adolescent smoking behaviour. Cross-sectional survey data of 2,044 secondary school students aged 12-17 years was combined with tobacco outlet audit data. Associations between students' self-reported tobacco use and the density of tobacco outlets near schools was examined using multilevel logistic and negative binomial regression models, with cigarette price at local milk bars and key socio-demographic and school-related variables included as covariates. Increased tobacco retail outlet density was associated with a significant increase in the number of cigarettes smoked in the previous seven days among students who smoked in the past month (IRR=1.13; 95% CI 1.02-1.26), but not the odds of smoking in the past month in the larger sample (OR=1.06; 95% CI 0.90-1.24), after controlling for local mean price of cigarettes and socio-demographic and school-related variables. This study suggests there is a positive association between tobacco retail outlet density and cigarette consumption among adolescent smokers, but not smoking prevalence, in the Australian context. There is value in considering policy measures that restrict the supply of tobacco retail outlets in school neighbourhoods as a means of reducing youth cigarette consumption.

  8. Giant Hepatic Hemangioma Presenting as Gastric Outlet Obstruction

    PubMed Central

    Aydin, Cemalettin; Akbulut, Sami; Kutluturk, Koray; Kahraman, Aysegul; Kayaalp, Cuneyt; Yilmaz, Sezai

    2013-01-01

    Hemangioma, a most frequently encountered primary benign tumor of the liver, is generally determined incidentally during the course of radiologic tests for other reasons. Most lesions are less than 3 cm and a significant proportion of patients are asymptomatic, although the size and location of the lesion in some patients may be associated with the onset of symptoms. Pressure on the stomach and duodenum of giant hemagiomas developing in the left lobe of the liver, in particular, may result in the development of abdominal pain, nausea, vomiting, and feeling bloated, which are characteristic of a gastric outlet obstruction. A 42-year-old man presented with findings of gastric outlet obstruction and weight loss as a result of a giant hepatic hemangioma. PMID:23438272

  9. Wastewater Collection.

    ERIC Educational Resources Information Center

    Chatterjee, Samar; And Others

    1978-01-01

    Presents a literature review of wastewater collection systems and components. This review covers: (1) planning, (2) construction; (3) sewer system evaluation; (4) maintenance; (5) rehabilitation; (6) overview prevention; and (7) wastewater pumping. A list of 111 references is also presented. (HM)

  10. Distances to on- and off-premise alcohol outlets and experiences of alcohol-related amenity problems.

    PubMed

    Wilkinson, Claire; Livingston, Michael

    2012-06-01

    There are a number of studies in recent years that have examined the relationship of alcohol outlets to the incidence of alcohol-related problems. Only a small number of these studies examine the types of alcohol-related problems which may be considered amenity problems, such as neighbourhood disturbance, litter and noise. This paper examines the association between the proximity of someone's home to alcohol outlets and their experience of public amenity problems. Data came from an Australian general population survey: the Alcohol's Harm to Others Survey (2008). Two thousand six hundred and forty-nine Australians aged 18 years and over were asked about their experiences of a number of amenity-type problems and the distance they lived to the nearest on- and off-premise alcohol outlet. Bivariate results showed that respondents living closer to on- and off-premise outlets reported more problems, with minor differences by distance to on- and off-premise outlet. In multivariate logistic regression analyses, controlling for possible confounding effects of the respondent and neighbourhood characteristics, living closer to on-premise outlets was independently associated with reporting being kept awake or disturbed at night and living closer to an off-premise outlet was independently associated with reporting property damage. A possible interpretation of the results is that respondents living close to on- and off-premise outlets experience more amenity problems than those living further away, but that these experiences are concentrated among demographic groups who live in these areas. Direction of influence cannot be inferred from these cross-sectional findings. © 2011 Australasian Professional Society on Alcohol and other Drugs.

  11. Wastewater garden--a system to treat wastewater with environmental benefits to community.

    PubMed

    Nair, Jaya

    2008-01-01

    Many communities and villages around the world face serious problems with lack of sanitation especially in disposing of the wastewater-black water and grey water from the houses, or wash outs from animal rearing sheds. Across the world diverting wastewater to the surroundings or to the public spaces are not uncommon. This is responsible for contaminating drinking water sources causing health risks and environmental degradation as they become the breeding grounds of mosquitoes and pathogens. Lack of collection and treatment facilities or broken down sewage systems noticed throughout the developing world are associated with this situation. Diverting the wastewater to trees and vegetable gardens was historically a common practice. However the modern world has an array of problems associated with such disposal such as generation of large quantity of wastewater, unavailability of space for onsite disposal or treatment and increase in population. This paper considers the wastewater garden as a means for wastewater treatment and to improve the vegetation and biodiversity of rural areas. This can also be implemented in urban areas in association with parks and open spaces. This also highlights environmental safety in relation to the nutrient, pathogen and heavy metal content of the wastewater. The possibilities of different types of integration and technology that can be adopted for wastewater gardens are also discussed. IWA Publishing 2008.

  12. Biohydrogen production from industrial wastewaters.

    PubMed

    Moreno-Andrade, Iván; Moreno, Gloria; Kumar, Gopalakrishnan; Buitrón, Germán

    2015-01-01

    The feasibility of producing hydrogen from various industrial wastes, such as vinasses (sugar and tequila industries), and raw and physicochemical-treated wastewater from the plastic industry and toilet aircraft wastewater, was evaluated. The results showed that the tequila vinasses presented the maximum hydrogen generation potential, followed by the raw plastic industry wastewater, aircraft wastewater, and physicochemical-treated wastewater from the plastic industry and sugar vinasses, respectively. The hydrogen production from the aircraft wastewater was increased by the adaptation of the microorganisms in the anaerobic sequencing batch reactor.

  13. 49 CFR 179.220-18 - Bottom outlets.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) SPECIFICATIONS FOR TANK CARS Specifications for Non-Pressure Tank Car Tanks (Classes DOT-111AW and 115AW) § 179.220-18 Bottom outlets. (a) The inner container...

  14. 49 CFR 179.103-5 - Bottom outlets.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) SPECIFICATIONS FOR TANK CARS Specifications for Pressure Tank Car Tanks (Classes DOT-105, 109, 112, 114 and 120) § 179.103-5 Bottom outlets. (a) In addition to...

  15. 49 CFR 179.103-5 - Bottom outlets.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) SPECIFICATIONS FOR TANK CARS Specifications for Pressure Tank Car Tanks (Classes DOT-105, 109, 112, 114 and 120) § 179.103-5 Bottom outlets. (a) In addition to...

  16. 49 CFR 179.103-5 - Bottom outlets.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) SPECIFICATIONS FOR TANK CARS Specifications for Pressure Tank Car Tanks (Classes DOT-105, 109, 112, 114 and 120) § 179.103-5 Bottom outlets. (a) In addition to...

  17. 49 CFR 178.255-5 - Bottom discharge outlets.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... closure at it lower end. Each valve or plug shall be designed to insure against unseating due to stresses or shocks incident to transportation. Bottom outlets shall be adequately protected against handling...

  18. Microbial Community Profiles in Wastewaters from Onsite Wastewater Treatment Systems Technology

    PubMed Central

    Jałowiecki, Łukasz; Chojniak, Joanna Małgorzata; Dorgeloh, Elmar; Hegedusova, Berta; Ejhed, Helene; Magnér, Jörgen; Płaza, Grażyna Anna

    2016-01-01

    The aim of the study was to determine the potential of community-level physiological profiles (CLPPs) methodology as an assay for characterization of the metabolic diversity of wastewater samples and to link the metabolic diversity patterns to efficiency of select onsite biological wastewater facilities. Metabolic fingerprints obtained from the selected samples were used to understand functional diversity implied by the carbon substrate shifts. Three different biological facilities of onsite wastewater treatment were evaluated: fixed bed reactor (technology A), trickling filter/biofilter system (technology B), and aerated filter system (the fluidized bed reactor, technology C). High similarities of the microbial community functional structures were found among the samples from the three onsite wastewater treatment plants (WWTPs), as shown by the diversity indices. Principal components analysis (PCA) showed that the diversity and CLPPs of microbial communities depended on the working efficiency of the wastewater treatment technologies. This study provided an overall picture of microbial community functional structures of investigated samples in WWTPs and discerned the linkages between microbial communities and technologies of onsite WWTPs used. The results obtained confirmed that metabolic profiles could be used to monitor treatment processes as valuable biological indicators of onsite wastewater treatment technologies efficiency. This is the first step toward understanding relations of technology types with microbial community patterns in raw and treated wastewaters. PMID:26807728

  19. Municipal wastewater biological nutrient removal driven by the fermentation liquid of dairy wastewater.

    PubMed

    Liu, Hui; Chen, Yinguang; Wu, Jiang

    2017-11-01

    Carbon substrate is required by biological nutrient removal (BNR) microorganism, but it is usually insufficient in the influent of many municipal wastewater treatment plants. In this study the use of ethanol-enriched fermentation liquid, which was derived from dairy wastewater, as the preferred carbon substrate of BNR was reported. First, the application of dairy wastewater and food processing wastewater and their fermentation liquid as the carbon substrate of BNR was compared in the short-term tests. The fermented wastewater showed higher BNR performance than the unfermented one, and the fermentation liquid of dairy wastewater (FL-DW), which was obtained under pH 8 and fermentation time of 6 day, exhibited the highest phosphorus (95.5%) and total nitrogen (97.6%) removal efficiencies due to its high ethanol content (57.9%). Then, the long-term performance of FL-DW acting as the carbon substrate of BNR was compared with that of acetate and ethanol, and the FL-DW showed the greatest phosphorus and total nitrogen removal. Further investigation showed that the use of FL-DW caused the highest polyhydroxyalkanoates (PHAs) synthesis in BNR microbial cells, and more PHAs were used for phosphorus uptake and denitrification rather than glycogen synthesis and microbial growth. The FL-DW can be used as a preferred carbon substrate for BNR microbes. AB: aerobic end sludge active biomass; BNR: biological nutrient removal; DW: dairy wastewater; FL-DW: fermentation liquid of dairy wastewater; FPW: food processing wastewater; FL-FPW: fermentation liquid of food processing wastewater; PHAs: polyhydroxyalkanoates; PHB: poly-3-hydroxybutyrate; PHV: poly-3-hydroxyvalerate; PH2MV: poly-3-hydroxy-2- methylvalerate; PAOs: phosphorus accumulating organisms; SBR: sequencing batch reactor; SOP: soluble ortho-phosphorus; TN: total nitrogen; TSS: total suspended solids; VSS: volatile suspended solids; VFAs: volatile fatty acids; WWTPs: wastewater treatment plants.

  20. Association Between Distance From Home to Tobacco Outlet and Smoking Cessation and Relapse.

    PubMed

    Pulakka, Anna; Halonen, Jaana I; Kawachi, Ichiro; Pentti, Jaana; Stenholm, Sari; Jokela, Markus; Kaate, Ilkka; Koskenvuo, Markku; Vahtera, Jussi; Kivimäki, Mika

    2016-10-01

    Reduced availability of tobacco outlets is hypothesized to reduce smoking, but longitudinal evidence on this issue is scarce. To examine whether changes in distance from home to tobacco outlet are associated with changes in smoking behaviors. The data from 2 prospective cohort studies included geocoded residential addresses, addresses of tobacco outlets, and responses to smoking surveys in 2008 and 2012 (the Finnish Public Sector [FPS] study, n = 53 755) or 2003 and 2012 (the Health and Social Support [HeSSup] study, n = 11 924). All participants were smokers or ex-smokers at baseline. We used logistic regression in between-individual analyses and conditional logistic regression in case-crossover design analyses to examine change in walking distance from home to the nearest tobacco outlet as a predictor of quitting smoking in smokers and smoking relapse in ex-smokers. Study-specific estimates were pooled using fixed-effect meta-analysis. Walking distance from home to the nearest tobacco outlet. Quitting smoking and smoking relapse as indicated by self-reported current and previous smoking at baseline and follow-up. Overall, 20 729 men and women (age range 18-75 years) were recruited. Of the 6259 and 2090 baseline current smokers, 1744 (28%) and 818 (39%) quit, and of the 8959 and 3421 baseline ex-smokers, 617 (7%) and 205 (6%) relapsed in the FPS and HeSSup studies, respectively. Among the baseline smokers, a 500-m increase in distance from home to the nearest tobacco outlet was associated with a 16% increase in odds of quitting smoking in the between-individual analysis (pooled odds ratio, 1.16; 95% CI, 1.05-1.28) and 57% increase in within-individual analysis (pooled odds ratio, 1.57; 95% CI, 1.32-1.86), after adjusting for changes in self-reported marital and working status, substantial worsening of financial situation, illness in the family, and own health status. Increase in distance to the nearest tobacco outlet was not associated with smoking

  1. Numerical Study of Outlet Boundary Conditions for Unsteady Turbulent Internal Flows Using the NCC

    NASA Technical Reports Server (NTRS)

    Liu, Nan-Suey; Shih, Tsan-Hsing

    2009-01-01

    This paper presents the results of studies on the outlet boundary conditions for turbulent internal flow simulations. Several outlet boundary conditions have been investigated by applying the National Combustion Code (NCC) to the configuration of a LM6000 single injector flame tube. First of all, very large eddy simulations (VLES) have been performed using the partially resolved numerical simulation (PRNS) approach, in which both the nonlinear and linear dynamic subscale models were employed. Secondly, unsteady Reynolds averaged Navier- Stokes (URANS) simulations have also been performed for the same configuration to investigate the effects of different outlet boundary conditions in the context of URANS. Thirdly, the possible role of the initial condition is inspected by using three different initial flow fields for both the PRNS/VLES simulation and the URANS simulation. The same grid is used for all the simulations and the number of mesh element is about 0.5 million. The main purpose of this study is to examine the long-time behavior of the solution as determined by the imposed outlet boundary conditions. For a particular simulation to be considered as successful under the given initial and boundary conditions, the solution must be sustainable in a physically meaningful manner over a sufficiently long period of time. The commonly used outlet boundary condition for steady Reynolds averaged Navier-Stokes (RANS) simulation is a fixed pressure at the outlet with all the other dependent variables being extrapolated from the interior. The results of the present study suggest that this is also workable for the URANS simulation of the LM6000 injector flame tube. However, it does not work for the PRNS/VLES simulation due to the unphysical reflections of the pressure disturbances at the outlet boundary. This undesirable situation can be practically alleviated by applying a simple unsteady convection equation for the pressure disturbances at the outlet boundary. The

  2. From Medical to Recreational Marijuana Sales: Marijuana Outlets and Crime in an Era of Changing Marijuana Legislation.

    PubMed

    Freisthler, Bridget; Gaidus, Andrew; Tam, Christina; Ponicki, William R; Gruenewald, Paul J

    2017-06-01

    A movement from medical to recreational marijuana use allows for a larger base of potential users who have easier access to marijuana, because they do not have to visit a physician before using marijuana. This study examines whether changes in the density of marijuana outlets were related to violent, property, and marijuana-specific crimes in Denver, CO during a time in which marijuana outlets began selling marijuana for recreational, and not just medical, use. We collected data on locations of crimes, marijuana outlets and covariates for 481 Census block groups over 34 months (N = 16,354 space-time units). A Bayesian Poisson space-time model assessed statistical relationships between independent measures and crime counts within "local" Census block groups. We examined spatial "lag" effects to assess whether crimes in Census block groups adjacent to locations of outlets were also affected. Independent of the effects of covariates, densities of marijuana outlets were unrelated to property and violent crimes in local areas. However, the density of marijuana outlets in spatially adjacent areas was positively related to property crime in spatially adjacent areas over time. Further, the density of marijuana outlets in local and spatially adjacent blocks groups was related to higher rates of marijuana-specific crime. This study suggests that the effects of the availability of marijuana outlets on crime do not necessarily occur within the specific areas within which these outlets are located, but may occur in adjacent areas. Thus studies assessing the effects of these outlets in local areas alone may risk underestimating their true effects.

  3. Durability of hand-sewn valves in the right ventricular outlet.

    PubMed

    Nunn, Graham R; Bennetts, Jayme; Onikul, Ella

    2008-08-01

    The objective was to compare the medium- and long-term outcomes for pericardial monocusp valves, polytetrafluoroethylene (Gore-Tex, WL Gore and Associates Inc, Flagstaff, Ariz) 0.1-mm monocusp valves, and bileaflet 0.l-mm polytetrafluoroethylene valves and their efficiency in the right ventricular outlet. We reviewed all hand-sewn right ventricular outlet valves created by the author (Graham R. Nunn) in the setting of repaired tetralogy of Fallot or equivalent right ventricular outlet pathology when the native pulmonary valve could not be preserved. The valves were assessed by serial transthoracic echocardiography and more recently by magnetic resonance imaging angiography for late valve function. The bileaflet polytetrafluoroethylene valves were constructed in a standardized fashion from a semicircle of 0.1-mm polytetrafluoroethylene (the radius of which equaled the length of the outflow tract incision) that gave a lengthened free edge to the leaflets, central fixation of the free edge posteriorly just proximal to the branch pulmonary arteries, and generous augmentation of the outflow tract with polytetrafluoroethylene patch-plasty. The bileaflet configuration shortens the closing time against the posterior wall, and the leaflets are forced to maintain their configuration without prolapse into the right ventricular outlet. The valve can be generously oversized in young children to try to avoid the need for replacement. A total of 54 patients met the selection criteria--22 patients received fresh autologous pericardial monocusps, 7 patients received polytetrafluoroethylene (0.1-mm) monocusps, and 25 patients received bileaflet polytetrafluoroethylene (0.1-mm) outlet valves. The pericardial valves have the longest follow-up, and all valves developed free pulmonary incompetence. Polytetrafluoroethylene monocusps had reliable competence early after surgery but progressed to pulmonary incompetence. The bileaflet polytetrafluoroethylene (0.1-mm) valves have remained

  4. Velocities of antarctic outlet glaciers determined from sequential Landsat images

    USGS Publications Warehouse

    MacDonald, Thomas R.; Ferrigno, Jane G.; Williams, Richard S.; Lucchitta, Baerbel K.

    1989-01-01

    Approximately 91.0 percent of the volume of present-day glacier ice on Earth is in Antarctica; Greenland contains about another 8.3 percent of the volume. Thus, together, these two great ice sheets account for an estimated 99.3 percent of the total. Long-term changes in the volume of glacier ice on our planet are the result of global climate change. Because of the relationship of global ice volume to sea level (± 330 cubic kilometers of glacier ice equals ± 1 millimeter sea level), changes in the mass balance of the antarctic ice sheet are of particular importance.Whether the mass balance of the east and west antarctic ice sheets is positive or negative is not known. Estimates of mass input by total annual precipitation for the continent have been made from scattered meteorological observations (Swithinbank 1985). The magnitude of annual ablation of the ice sheet from calving of outlet glaciers and ice shelves is also not well known. Although the velocities of outlet glaciers can be determined from field measurements during the austral summer,the technique is costly, does not cover a complete annual cycle,and has been applied to just a few glaciers. To increase the number of outlet glaciers in Antarctica for which velocities have been determined and to provide additional data for under-standing the dynamics of the antarctic ice sheets and their response to global climate change, sequential Landsat image of several outlet glaciers were measured.

  5. Neighborhood alcohol outlet density and genetic influences on alcohol use: evidence for gene-environment interaction.

    PubMed

    Slutske, Wendy S; Deutsch, Arielle R; Piasecki, Thomas M

    2018-05-07

    Genetic influences on alcohol involvement are likely to vary as a function of the 'alcohol environment,' given that exposure to alcohol is a necessary precondition for genetic risk to be expressed. However, few gene-environment interaction studies of alcohol involvement have focused on characteristics of the community-level alcohol environment. The goal of this study was to examine whether living in a community with more alcohol outlets would facilitate the expression of the genetic propensity to drink in a genetically-informed national survey of United States young adults. The participants were 2434 18-26-year-old twin, full-, and half-sibling pairs from Wave III of the National Longitudinal Study of Adolescent to Adult Health. Participants completed in-home interviews in which alcohol use was assessed. Alcohol outlet densities were extracted from state-level liquor license databases aggregated at the census tract level to derive the density of outlets. There was evidence that the estimates of genetic and environmental influences on alcohol use varied as a function of the density of alcohol outlets in the community. For example, the heritability of the frequency of alcohol use for those residing in a neighborhood with ten or more outlets was 74% (95% confidence limits = 55-94%), compared with 16% (95% confidence limits = 0-34%) for those in a neighborhood with zero outlets. This moderating effect of alcohol outlet density was not explained by the state of residence, population density, or neighborhood sociodemographic characteristics. The results suggest that living in a neighborhood with many alcohol outlets may be especially high-risk for those individuals who are genetically predisposed to frequently drink.

  6. The subclavius posticus muscle: an unusual cause of thoracic outlet syndrome.

    PubMed

    Smayra, T; Nabhane, L; Tabet, G; Menassa-Moussa, L; Hachem, K; Haddad-Zebouni, S

    2014-09-01

    We present the case of a 30-year-old female, complaining of thoracic outlet compression symptoms caused by a supernumerary muscle, the subclavius posticus, accompanied by a caudally inserted middle scalenus muscle on the second rib. This rare anatomic variant was clearly shown on CT angiography and MRI images and surgical treatment was successful. As first described by Rosenmuller in 1800, subclavius posticus is a supernumerary muscle originating from the cranial surface of the sternal end of the first rib, running laterodorsally beneath the clavicle, and inserting into the superior border of the scapula. Its role in thoracic outlet syndrome has been seldom demonstrated in living patients nor described in imaging, although it is theoretically easily recognizable on modern imaging modalities. It should be taken into account during workout of patients with thoracic outlet syndrome, since it can be potentially treated.

  7. Development of a solenoid actuated planar valveless micropump with single and multiple inlet-outlet arrangements

    NASA Astrophysics Data System (ADS)

    Kumar, N.; George, D.; Sajeesh, P.; Manivannan, P. V.; Sen, A. K.

    2016-07-01

    We report a planar solenoid actuated valveless micropump with multiple inlet-outlet configurations. The self-priming characteristics of the multiple inlet-multiple outlet micropump are studied. The filling dynamics of the micropump chamber during start-up and the effects of fluid viscosity, voltage and frequency on the dynamics are investigated. Numerical simulations for multiple inlet-multiple outlet micropumps are carried out using fluid structure algorithm. With DI water and at 5.0 Vp-p, 20 Hz frequency, the two inlet-two outlet micropump provides a maximum flow rate of 336 μl min-1 and maximum back pressure of 441 Pa. Performance characteristics of the two inlet-two outlet micropump are studied for aqueous fluids of different viscosity. Transport of biological cell lines and diluted blood samples are demonstrated; the flow rate-frequency characteristics are studied. Viability of cells during pumping with multiple inlet multiple outlet configuration is also studied in this work, which shows 100% of cells are viable. Application of the proposed micropump for simultaneous pumping, mixing and distribution of fluids is demonstrated. The proposed integrated, standalone and portable micropump is suitable for drug delivery, lab-on-chip and micro-total-analysis applications.

  8. Wastewater Treatment

    MedlinePlus

    ... cleaned, water can carry disease. Since we live, work and play so close to water, harmful bacteria have to be removed to make water safe. Effects of wastewater pollutants If wastewater is not properly treated, then the environment and human health can be negatively impacted. These ...

  9. Characterizing convective cold pools: Characterizing Convective Cold Pools

    DOE PAGES

    Drager, Aryeh J.; van den Heever, Susan C.

    2017-05-09

    Cold pools produced by convective storms play an important role in Earth's climate system. However, a common framework does not exist for objectively identifying convective cold pools in observations and models. The present study investigates convective cold pools within a simulation of tropical continental convection that uses a cloud-resolving model with a coupled land-surface model. Multiple variables are assessed for their potential in identifying convective cold pool boundaries, and a novel technique is developed and tested for identifying and tracking cold pools in numerical model simulations. This algorithm is based on surface rainfall rates and radial gradients in the densitymore » potential temperature field. The algorithm successfully identifies near-surface cold pool boundaries and is able to distinguish between connected cold pools. Once cold pools have been identified and tracked, composites of cold pool evolution are then constructed, and average cold pool properties are investigated. Wet patches are found to develop within the centers of cold pools where the ground has been soaked with rainwater. These wet patches help to maintain cool surface temperatures and reduce cold pool dissipation, which has implications for the development of subsequent convection.« less

  10. Characterizing convective cold pools: Characterizing Convective Cold Pools

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Drager, Aryeh J.; van den Heever, Susan C.

    Cold pools produced by convective storms play an important role in Earth's climate system. However, a common framework does not exist for objectively identifying convective cold pools in observations and models. The present study investigates convective cold pools within a simulation of tropical continental convection that uses a cloud-resolving model with a coupled land-surface model. Multiple variables are assessed for their potential in identifying convective cold pool boundaries, and a novel technique is developed and tested for identifying and tracking cold pools in numerical model simulations. This algorithm is based on surface rainfall rates and radial gradients in the densitymore » potential temperature field. The algorithm successfully identifies near-surface cold pool boundaries and is able to distinguish between connected cold pools. Once cold pools have been identified and tracked, composites of cold pool evolution are then constructed, and average cold pool properties are investigated. Wet patches are found to develop within the centers of cold pools where the ground has been soaked with rainwater. These wet patches help to maintain cool surface temperatures and reduce cold pool dissipation, which has implications for the development of subsequent convection.« less

  11. The association between the geography of fast food outlets and childhood obesity rates in Leeds, UK.

    PubMed

    Fraser, Lorna K; Edwards, Kimberley L

    2010-11-01

    To analyse the association between childhood overweight and obesity and the density and proximity of fast food outlets in relation to the child's residential postcode. This was an observational study using individual level height/weight data and geographic information systems methodology. Leeds in West Yorkshire, UK. This area consists of 476 lower super-output areas. Children aged 3-14 years who lived within the Leeds metropolitan boundaries (n=33,594). The number of fast food outlets per area and the distance to the nearest fast food outlet from the child's home address. The weight status of the child: overweight, obese or neither. 27.1% of the children were overweight or obese with 12.6% classified as obese. There is a significant positive correlation (p<0.001) between density of fast food outlets and higher deprivation. A higher density of fast food outlets was significantly associated (p=0.02) with the child being obese (or overweight/obese) in the generalised estimating equation model which also included sex, age and deprivation. No significant association between distance to the nearest fast food outlet and overweight or obese status was found. There is a positive relationship between the density of fast food outlets per area and the obesity status of children in Leeds. There is also a significant association between fast food outlet density and areas of higher deprivation. Copyright © 2010 Elsevier Ltd. All rights reserved.

  12. The Moderating Role of Gender in the Relationship Between Tobacco Outlet Exposure and Tobacco Use Among African American Young Adults.

    PubMed

    Brown, Qiana; Milam, Adam J; Bowie, Janice V; Ialongo, Nicholas S; Gaskin, Darrell J; Furr-Holden, Debra

    2016-04-01

    Tobacco outlet exposure is a correlate of tobacco use with potential differences by gender that warrant attention. The aim of this study is to explore the moderating role of gender in the relationship between tobacco outlet exposure and past month tobacco use among African American young adults 21 to 24 years old. This cross-sectional study (n = 283) used geospatial methods to determine the number of tobacco outlets within walking distance (i.e., a quarter mile) of participants' homes and distance to the nearest outlet. Logistic regression models were used to test interactions between gender and tobacco outlet exposure (i.e., density and proximity). Tobacco outlets were classified based on whether or not they were licensed to sell tobacco only (TO outlets) or tobacco and alcohol (TA outlets). Neither density nor proximity was associated with past month tobacco use in the pooled models. However, gender modified the relationship between TO outlet density and tobacco use, and this relationship was significant only among women (OR = 1.02; p < 0.01; adjusted OR = 1.01; p < 0.05). This study underscores the importance of reducing tobacco outlet density in residential neighborhoods, especially TO outlets, as well as highlights potential gender differences in the relationship between tobacco outlet density and tobacco use.

  13. 16 CFR Appendix D to Part 436 - Sample Item 20(3) Table-Status of Franchise Outlets

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 16 Commercial Practices 1 2013-01-01 2013-01-01 false Sample Item 20(3) Table-Status of Franchise Outlets D Appendix D to Part 436 Commercial Practices FEDERAL TRADE COMMISSION TRADE REGULATION RULES... Item 20(3) Table—Status of Franchise Outlets Status of Franchise Outlets For years 2004 to 2006 Column...

  14. 16 CFR Appendix D to Part 436 - Sample Item 20(3) Table-Status of Franchise Outlets

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 16 Commercial Practices 1 2014-01-01 2014-01-01 false Sample Item 20(3) Table-Status of Franchise Outlets D Appendix D to Part 436 Commercial Practices FEDERAL TRADE COMMISSION TRADE REGULATION RULES... Item 20(3) Table—Status of Franchise Outlets Status of Franchise Outlets For years 2004 to 2006 Column...

  15. 16 CFR Appendix D to Part 436 - Sample Item 20(3) Table-Status of Franchise Outlets

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 16 Commercial Practices 1 2010-01-01 2010-01-01 false Sample Item 20(3) Table-Status of Franchise Outlets D Appendix D to Part 436 Commercial Practices FEDERAL TRADE COMMISSION TRADE REGULATION RULES... Item 20(3) Table—Status of Franchise Outlets Status of Franchise Outlets For years 2004 to 2006 Column...

  16. 16 CFR Appendix D to Part 436 - Sample Item 20(3) Table-Status of Franchise Outlets

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 16 Commercial Practices 1 2011-01-01 2011-01-01 false Sample Item 20(3) Table-Status of Franchise Outlets D Appendix D to Part 436 Commercial Practices FEDERAL TRADE COMMISSION TRADE REGULATION RULES... Item 20(3) Table—Status of Franchise Outlets Status of Franchise Outlets For years 2004 to 2006 Column...

  17. 16 CFR Appendix D to Part 436 - Sample Item 20(3) Table-Status of Franchise Outlets

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 16 Commercial Practices 1 2012-01-01 2012-01-01 false Sample Item 20(3) Table-Status of Franchise Outlets D Appendix D to Part 436 Commercial Practices FEDERAL TRADE COMMISSION TRADE REGULATION RULES... Item 20(3) Table—Status of Franchise Outlets Status of Franchise Outlets For years 2004 to 2006 Column...

  18. Examining the interaction between food outlets and outdoor food advertisements with primary school food environments.

    PubMed

    Walton, Mat; Pearce, Jamie; Day, Peter

    2009-09-01

    Schools are commonly seen as a site of intervention to improve children's nutrition, and prevent excess weight gain. Schools may have limited influence over children's diets; however, with home and community environments also exerting an influence within schools. This study considered the environment of food outlets and outdoor food advertisements surrounding four case study primary schools in New Zealand, and the impact of that external environment on within-school food environments. The shortest travel route between school and home addresses, and the number of food outlets and advertisements passed on that route, was calculated for each student. Interviews with school management were conducted. The schools with a higher percentage of students passing food outlets and advertisements considered that their presence impacted on efforts within schools to improve the food environment. Limiting students' exposure to food outlets and outdoor food adverts through travel route planning, reducing advertising, or limiting the location of food outlets surrounding schools could be explored as intervention options to support schools in promoting nutrition.

  19. Wastewater: A Potential Bioenergy Resource.

    PubMed

    Prakash, Jyotsana; Sharma, Rakesh; Ray, Subhasree; Koul, Shikha; Kalia, Vipin Chandra

    2018-06-01

    Wastewaters are a rich source of nutrients for microorganisms. However, if left unattended the biodegradation may lead to severe environmental hazards. The wastewaters can thus be utilized for the production of various value added products including bioenergy (H 2 and CH 4 ). A number of studies have reported utilization of various wastewaters for energy production. Depending on the nature of the wastewater, different reactor configurations, wastewater and inoculum pretreatments, co-substrate utilizations along with other process parameters have been studied for efficient product formation. Only a few studies have reported sequential utilization of wastewaters for H 2 and CH 4 production despite its huge potential for complete waste degradation.

  20. Treatment of high salinity organic wastewater by membrane electrolysis

    NASA Astrophysics Data System (ADS)

    Dongfang, Shen; Jinghuan, Ma; Ying, Liu; Chenguang, Zhao

    2018-03-01

    The effects of different operating conditions on the treatment of electrolytic wastewater were investigated by analyzing the removal rate of ammonia and COD before and after wastewater treatment by cation exchange membrane. Experiment shows that as the running time increases the electrolysis effect first increases after the smooth. The removal rate of ammonia will increase with the increase of current density, and the removal rate of COD will increase first and then decrease with the increase of current density. The increase of the temperature of the electrolytic solution will slowly increase the COD removal rate to saturation, but does not affect the removal of ammonia nitrogen. When the flow rate is less than 60L / h, the change of influent flow rate will not affect the removal of ammonia nitrogen, but the effect on COD is small, which will increase and decrease slightly. After the experiment, the surface of the cation exchange membrane was analyzed by cold field scanning electron microscopy and X-ray energy dispersive spectrometer. The surface contamination and the pollutant were determined. The experimental results showed that the aggregates were mainly chlorinated Sodium, calcium and magnesium inorganic salts, which will change the morphology of the film to reduce porosity, reduce the mass transfer efficiency, affecting the electrolysis effect.

  1. Norovirus Dynamics in Wastewater Discharges and in the Recipient Drinking Water Source: Long-Term Monitoring and Hydrodynamic Modeling.

    PubMed

    Dienus, Olaf; Sokolova, Ekaterina; Nyström, Fredrik; Matussek, Andreas; Löfgren, Sture; Blom, Lena; Pettersson, Thomas J R; Lindgren, Per-Eric

    2016-10-04

    Norovirus (NoV) that enters drinking water sources with wastewater discharges is a common cause of waterborne outbreaks. The impact of wastewater treatment plants (WWTPs) on the river Göta älv (Sweden) was studied using monitoring and hydrodynamic modeling. The concentrations of NoV genogroups (GG) I and II in samples collected at WWTPs and drinking water intakes (source water) during one year were quantified using duplex real-time reverse-transcription polymerase chain reaction. The mean (standard deviation) NoV GGI and GGII genome concentrations were 6.2 (1.4) and 6.8 (1.8) in incoming wastewater and 5.3 (1.4) and 5.9 (1.4) log 10 genome equivalents (g.e.) L -1 in treated wastewater, respectively. The reduction at the WWTPs varied between 0.4 and 1.1 log 10 units. In source water, the concentration ranged from below the detection limit to 3.8 log 10 g.e. L -1 . NoV GGII was detected in both wastewater and source water more frequently during the cold than the warm period of the year. The spread of NoV in the river was simulated using a three-dimensional hydrodynamic model. The modeling results indicated that the NoV GGI and GGII genome concentrations in source water may occasionally be up to 2.8 and 1.9 log 10 units higher, respectively, than the concentrations measured during the monitoring project.

  2. Corrosive-induced gastric outlet obstruction without oesphageal involvement: a case report.

    PubMed

    Ali, N; Eni, U E

    2005-01-01

    The objective of this paper is to report an unusual case of isolated gastric outlet obstruction following corrosive ingestion. A case report of a 28-year old female seen by the authors. The literature on gastric outlet obstruction following ingestion of corrosives is reviewed briefly. Features of worsening gastric outlet obstruction were found in this 28-year old female five months after ingestion of hydrochloric acid. There was an antecedent history of depressive illness. The upper gastrointestinal barium contrast radiographs showed a normal oesophagus and proximal stomach. The distal stomach was however scarred, contracted with severe antropyloric stenosis. She underwent nutritional rehabilitation with high protein diet and made an uneventful recovery after a gastrojejunostomy. This case suggests a relative resistance of the oesophagus to corrosive acids as reported in the literature. The stomach, however, is more susceptible to acids causing burns with subsequent cicatrisation around the antrum and pylorus.

  3. Expiry of medicines in supply outlets in Uganda.

    PubMed

    Nakyanzi, Josephine Katabaazi; Kitutu, Freddy Eric; Oria, Hussein; Kamba, Pakoyo Fadhiru

    2010-02-01

    The expiry of medicines in the supply chain is a serious threat to the already constrained access to medicines in developing countries. We investigated the extent of, and the main contributing factors to, expiry of medicines in medicine supply outlets in Kampala and Entebbe, Uganda. A cross-sectional survey of six public and 32 private medicine outlets was done using semi-structured questionnaires. The study area has 19 public medicine outlets (three non-profit wholesalers, 16 hospital stores/pharmacies), 123 private wholesale pharmacies and 173 retail pharmacies, equivalent to about 70% of the country's pharmaceutical businesses. Our findings indicate that medicines prone to expiry include those used for vertical programmes, donated medicines and those with a slow turnover. Awareness about the threat of expiry of medicines to the delivery of health services has increased. We have adapted training modules to emphasize management of medicine expiry for pharmacy students, pharmacists and other persons handling medicines. Our work has also generated more research interest on medicine expiry in Uganda. Even essential medicines expire in the supply chain in Uganda. Sound coordination is needed between public medicine wholesalers and their clients to harmonize procurement and consumption as well as with vertical programmes to prevent duplicate procurement. Additionally, national medicine regulatory authorities should enforce existing international guidelines to prevent dumping of donated medicine. Medicine selection and quantification should be matched with consumer tastes and prescribing habits. Lean supply and stock rotation should be considered.

  4. Review of recent developments and applications in low-pressure (vacuum outlet) gas chromatography

    USDA-ARS?s Scientific Manuscript database

    The concept of low pressure (LP) vacuum outlet gas chromatography (GC) was introduced more than 50 years ago, but it was not until the 2000s that its theoretical applicability to fast analysis of GC-amenable chemicals was realized. In practice, LPGC is implemented by placing the outlet of a short, ...

  5. Experimental study of flow distribution and pressure loss with circumferential inlet and outlet manifolds

    NASA Technical Reports Server (NTRS)

    Dittrich, R. T.

    1972-01-01

    Water flow tests with circumferential inlet and outlet manifolds were conducted to determine factors affecting fluid distribution and pressure losses. Various orifice sizes and manifold geometries were tested over a range of flow velocities. With inlet manifolds, flow distribution was related directly to orifice discharge coefficients. A correlation indicated that nonuniform distribution resulted when the velocity head ratio at the orifice was not in the range of constant discharge coefficient. With outlet manifolds, nonuniform flow was related to static pressure variations along the manifold. Outlet manifolds had appreciably greater pressure losses than comparable inlet manifolds.

  6. 49 CFR 179.200-17 - Bottom outlets.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... valve due to stresses or shocks incident to transportation. (5) Bottom outlet nozzle of interior valves..., they must be of good weldable quality in conjunction with metal of tank. (6) To provide for the... welded to tank, they shall be of good weldable quality in conjunction with metal of tank. (3) If the...

  7. 49 CFR 179.200-17 - Bottom outlets.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... valve due to stresses or shocks incident to transportation. (5) Bottom outlet nozzle of interior valves..., they must be of good weldable quality in conjunction with metal of tank. (6) To provide for the... welded to tank, they shall be of good weldable quality in conjunction with metal of tank. (3) If the...

  8. 49 CFR 179.200-17 - Bottom outlets.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... valve due to stresses or shocks incident to transportation. (5) Bottom outlet nozzle of interior valves..., they must be of good weldable quality in conjunction with metal of tank. (6) To provide for the... welded to tank, they shall be of good weldable quality in conjunction with metal of tank. (3) If the...

  9. 49 CFR 179.200-17 - Bottom outlets.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... valve due to stresses or shocks incident to transportation. (5) Bottom outlet nozzle of interior valves..., they must be of good weldable quality in conjunction with metal of tank. (6) To provide for the... welded to tank, they shall be of good weldable quality in conjunction with metal of tank. (3) If the...

  10. 49 CFR 179.200-17 - Bottom outlets.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... valve due to stresses or shocks incident to transportation. (5) Bottom outlet nozzle of interior valves..., they must be of good weldable quality in conjunction with metal of tank. (6) To provide for the... welded to tank, they shall be of good weldable quality in conjunction with metal of tank. (3) If the...

  11. Ayurvedic medicine in Mauritius: Profile of Ayurvedic outlet, use, sale, distribution, regulation and importation.

    PubMed

    Elaheebocus, Naailah; Mahomoodally, M Fawzi

    2017-02-02

    Ayurvedic medicine (AM) is a legalised alternative traditional medical system in the multicultural tropical island of Mauritius. A panoply of Ayurvedic specialised shops/centres involved in the provision of Ayurvedic services hereafter termed as 'outlets' operates in different regions of the island and is extensively exploited by a significant number of Mauritians. Nonetheless, there is currently no study geared towards studying the status of AM and profile of Ayurvedic outlets in Mauritius and there is undoubtedly a dearth of standardized regulatory framework governing the practice of AM in Mauritius. The present study attempts to study the profile of Ayurvedic outlets, sale, distribution, regulation and importation of AM in Mauritius. To evaluate the characteristics profile of Ayurvedic shops/clinics/pharmacies/centres, to document common Ayurvedic products used in the treatment and management of diseases, and to analyse existing regulatory control of AM in Mauritius. Ayurvedic outlets were identified using a random approach. Once permission granted, outlets were visited where face-to-face interviews with Ayurvedic practitioners/directors/dispensers were undertaken using a semi-structured questionnaire. The characteristics of the outlets with respect to the type of business registration, procurement and dispensing of products, registration and qualification of personnels employed amongst others were studied. The International Classification of Diseases (ICD) 10 was used to classify common AM dispensed to patients. Additionally, information was sought from local authorities pertaining to existing legislation governing the importation and regulation of AM in Mauritius. A total of 16 Ayurvedic outlets ('pharmacies' (n=3), clinics (n=2), shops (n=5) and centres (n=6)) was surveyed. Six outlets dispensed AM strictly on prescription only after consultation with an onsite full-time employed registered Ayurvedic practitioner. Seven outlets offered AM both on prescription

  12. Model evaluation of potential impacts of on-site wastewater systems on phosphorus in Turkey creek watershed.

    PubMed

    Geza, Mengistu; McCray, John E; Murray, Kyle E

    2010-01-01

    Nutrient loading to surface water systems has traditionally been associated with agricultural sources. Sources such as on-site wastewater systems (OWS) may be of concern especially in rural, nonagricultural watersheds. The impact of various point and nonpoint sources including OWS in Turkey Creek Watershed was evaluated using the Watershed Analysis Risk Management Framework, which was calibrated using 10 yr of observed stream flow and total P concentrations. Doubling the population in the watershed or OWS septic tank effluent P concentration increased mean stream total P concentration by a factor of 1.05. Converting all the OWS to a conventional sewer system with a removal efficiency of 93% at the wastewater treatment plant increased the mean total P concentration at the watershed outlet by a factor of 1.26. Reducing the soil adsorption capacity by 50% increased the mean stream total P concentration by a factor of 3.2. Doubling the initial P concentration increased the mean stream total P concentration by a factor of 1.96. Stream flow and sediment transport also substantially affected stream P concentration. The results suggest that OWS contribution to stream P in this watershed is minimal compared with other factors within the simulated time frame of 10 yr.

  13. Review of wastewater problems and wastewater-management planning in the San Francisco Bay region, California

    USGS Publications Warehouse

    Hines, Walter G.

    1973-01-01

    The San Francisco Bay region has suffered adverse environmental effects related to the discharge of municipal-, industrial-, and agricultural- wastewater and storm-water runoff. Specific pollutional properties of theses discharges are not well understood in all cases although the toxic materials and aquatic-plant nutrients (biostimulants) found in municipal and industrial waterwater are considered to be a major cause of regional water-quality problems. Other water-quality problems in the region are commonly attributed to pesticides found in agricultural wastewater and potentially pathogenic bacteria in municipal-wastewater discharges and in storm-water runoff. The geographical distribution and magnitude of wastewater discharges in the bay region, particularly those from municipalities and industries, is largely a function of population, economic growth, and urban development. As might be expected, the total volume of wastewater has increased in a trend paralleling this growth and development. More significant, perhaps, is the fact that the total volume parameters such as BOD (biochemical oxygen demand), biostimulant concentrations, and toxicity, has increased despite large expenditures on new and improved municipal- and industrial-wastewater-treatment plants. Also, pollutant loadings from other major source, such as agriculture and storm-water runoff, have increased. At the time of writing (1972), many Federal, State, regional, and local agencies are engaged in a comprehensive wastewater-management-planning effort for the entire bay region. Initial objectives of this planning effort are: (1) the consolidation and coordination of loosely integrated wastewater-management facilities and (2) the elimination of wastewater discharges to ecologically sensitive areas, such as fresh-water streams and shallow extremities of San Francisco Bay. There has been some investigation of potential long-range wastewater-management alternatives based upon disposal in deep water in the

  14. Understanding the Role of Accredited Drug Dispensing Outlets in Tanzania's Health System.

    PubMed

    Embrey, Martha; Vialle-Valentin, Catherine; Dillip, Angel; Kihiyo, Bernard; Mbwasi, Romuald; Semali, Innocent A; Chalker, John C; Liana, Jafary; Lieber, Rachel; Johnson, Keith; Rutta, Edmund; Kimatta, Suleiman; Shekalaghe, Elizabeth; Valimba, Richard; Ross-Degnan, Dennis

    2016-01-01

    referral (90%), or both (45%), which are recommended practices for managing pediatric pneumonia. However, one-third of the dispensers needlessly sold antibiotics for cold symptoms, and 85% sold an antibiotic on request. In addition, the pneumonia scenario elicited more advice on handling the illness than the cold symptoms scenario (61% vs. 15%; p<0.0001), but overall, only 44% of the dispensers asked any of the shoppers about danger signs potentially associated with pneumonia in a child. ADDOs are the principal source of medicines in Tanzania and an important part of a multi-faceted health care system. Poor prescribing in health facilities, poor dispensing at ADDOs, and inappropriate patient demand continue to contribute to inappropriate medicines use. Therefore, while accreditation has attempted to address the quality of pharmaceutical services in private sector drug outlets, efforts to improve access to and use of medicines in Tanzania need to target ADDOs, public/nongovernmental health facilities, and the public to be effective.

  15. Role of the cold water on the formation of the East Korean Warm Current in the East/Japan Sea : A numerical experiment

    NASA Astrophysics Data System (ADS)

    Kim, Y.; Kim, Y. H.; Cho, Y. K.

    2016-12-01

    The East/Japan Sea (EJS) is a marginal sea of the western Pacific with an average depth of 2,000 m. The water exchange between the EJS and the Pacific occurs through the Korea Strait and Tsugaru Strait corresponding to the inlet and outlet respectively. The Tsushima Current flowing into the ESJ through the Korea Strait is divided into two main branches, the Nearshore Branch flowing along the Japanese coast, and the East Korean Warm Current (EKWC) heading northward along the Korean coast. Many previous studies reported the effects of cold water on the formation of the EKWC using 2-dimensional model that was limited in the Korea Strait. However, 3-dimensional structure of the cold water in relation to the EKWC have not been examined. In this study, we investigated the effects of cold water on the formation of the EKWC using 3-dimension numerical model. Model results indicate that the thickness and relative vorticity of the upper layer decrease due to the presence of the lower cold water along the Korean coast. Correspondingly, the negative relative vorticity also intensifies the EKWC along the Korean coast.

  16. Effect of spiral outlet hydraulic passage geometrics on the radial thrust

    NASA Astrophysics Data System (ADS)

    Lugova, S. O.; Ignateva, P. I.

    2017-08-01

    The article presents the results of investigation of the effect of geometrics of a double-volute outlet hydraulic passage on the magnitude and direction of acting of the radial reaction forces in a between-bearings single-stage centrifugal pump with a double entry impeller. The investigation has been performed with the use of a computing experiment. Characteristic curves as well as values and directions of the radial thrust have been compared for three variants of outlet hydraulic passages differing in the width at their entrance.

  17. 7 CFR 929.61 - Outlets for excess cranberries.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing... MASSACHUSETTS, RHODE ISLAND, CONNECTICUT, NEW JERSEY, WISCONSIN, MICHIGAN, MINNESOTA, OREGON, WASHINGTON, AND LONG ISLAND IN THE STATE OF NEW YORK Order Regulating Handling Reports and Records § 929.61 Outlets for...

  18. Effect of blade outlet angle on radial thrust of single-blade centrifugal pump

    NASA Astrophysics Data System (ADS)

    Nishi, Y.; Fukutomi, J.; Fujiwara, R.

    2012-11-01

    Single-blade centrifugal pumps are widely used as sewage pumps. However, a large radial thrust acts on a single blade during pump operation because of the geometrical axial asymmetry of the impeller. This radial thrust causes vibrations of the pump shaft, reducing the service life of bearings and shaft seal devices. Therefore, to ensure pump reliability, it is necessary to quantitatively understand the radial thrust and clarify the behavior and generation mechanism. This study investigated the radial thrust acting on two kinds of single-blade centrifugal impellers having different blade outlet angles by experiments and computational fluid dynamics (CFD) analysis. Furthermore, the radial thrust was modeled by a combination of three components, inertia, momentum, and pressure, by applying an unsteady conservation of momentum to this impeller. As a result, the effects of the blade outlet angle on both the radial thrust and the modeled components were clarified. The total head of the impeller with a blade outlet angle of 16 degrees increases more than the impeller with a blade outlet angle of 8 degrees at a large flow rate. In this case, since the static pressure of the circumference of the impeller increases uniformly, the time-averaged value of the radial thrust of both impellers does not change at every flow rate. On the other hand, since the impeller blade loading becomes large, the fluctuation component of the radial thrust of the impeller with the blade outlet angle of 16 degrees increases. If the blade outlet angle increases, the fluctuation component of the inertia component will increase, but the time-averaged value of the inertia component is located near the origin despite changes in the flow rate. The fluctuation component of the momentum component becomes large at all flow rates. Furthermore, although the time-averaged value of the pressure component is almost constant, the fluctuation component of the pressure component becomes large at a large flow rate

  19. Supermarket and fast-food outlet exposure in Copenhagen: associations with socio-economic and demographic characteristics.

    PubMed

    Svastisalee, Chalida M; Nordahl, Helene; Glümer, Charlotte; Holstein, Bjørn E; Powell, Lisa M; Due, Pernille

    2011-09-01

    To investigate whether exposure to fast-food outlets and supermarkets is socio-economically patterned in the city of Copenhagen. The study was based on a cross-sectional multivariate approach to examine the association between the number of fast-food outlets and supermarkets and neighbourhood-level socio-economic indicators. Food business addresses were obtained from commercial and public business locators and geocoded using a geographic information system for all neighbourhoods in the city of Copenhagen (n 400). The regression of counts of fast-food outlets and supermarkets v. indicators of socio-economic status (percentage of recent immigrants, percentage without a high-school diploma, percentage of the population under 35 years of age and average household income in Euros) was performed using negative binomial analysis. Copenhagen, Denmark. The unit of analysis was neighbourhood (n 400). In the fully adjusted models, income was not a significant predictor for supermarket exposure. However, neighbourhoods with low and mid-low income were associated with significantly fewer fast-food outlets. Using backwise deletion from the fully adjusted models, low income remained significantly associated with fast-food outlet exposure (rate ratio = 0·66-0·80) in the final model. In the city of Copenhagen, there was no evidence of spatial patterning of supermarkets by income. However, we detected a trend in the exposure to fast-food outlets, such that neighbourhoods in the lowest income quartile had fewer fast-food outlets than higher-income neighbourhoods. These findings have similarities with studies conducted in the UK, but not in the USA. The results suggest there may be socio-economic factors other than income associated with food exposure in Europe.

  20. The impact of insecticide-treated material to reduce flies among pork outlets in Kampala, Uganda.

    PubMed

    Heilmann, Martin; Roesel, Kristina; Grace, Delia; Bauer, Burkhard; Clausen, Peter-Henning

    2017-06-01

    Synanthropic flies have adapted to the mass of decaying organic matter near human settlements. As such, they feed and breed on food, faeces and other organic material and are known vectors for various diseases. Many of these diseases are associated with food, and foodborne diseases are of growing concern in developing countries where human population and food consumption increase. This pilot study aims at investigating the impact of a novel application of insecticide-treated material (ZeroFly®) to reduce flies among pork outlets in Kampala, Uganda. A cross-sectional survey randomly selected 60 of 179 pork outlets in Kampala. A controlled longitudinal trial followed in which 23 out of the 60 pork outlets were recruited for an intervention with insecticide-treated material. The pork outlets were randomly allocated to a group of 18 netted pork outlets (intervention) and five non-netted pork outlets (control). Monitoring took place over 15 weeks including 2 weeks as the baseline survey. The units were monitored for fly abundance using non-attractant sticky traps, which were placed within the pork outlet once per week for 48 consecutive hours. Medians of fly numbers before and after the intervention indicated a decrease of fly numbers of 48% (p = 0.002). Fly bioassays showed that the insecticidal activity of the netting remained active over the entire intervention period and led to a total paralysis of flies within at least 6 h after exposure. Insecticide-treated material provides a practical and sustainable solution in controlling flies and is therefore recommended as a complementary strategy for an integrated vector control and hygiene management.

  1. The association between alcohol outlet density and alcohol use among urban and regional Australian adolescents.

    PubMed

    Azar, Denise; White, Victoria; Coomber, Kerri; Faulkner, Agatha; Livingston, Michael; Chikritzhs, Tanya; Room, Robin; Wakefield, Melanie

    2016-01-01

    While recent evidence suggests that higher alcohol outlet density is associated with greater alcohol use among adolescents, influence of the four main outlet types on youth drinking within urban and regional communities is unknown. This study provides the first investigation of this relationship. Repeated cross-sectional surveys with random samples of secondary students clustered by school. Mixed-effects logistic regression analyses examined the association between each outlet type and the drinking outcomes, with interaction terms used to test urban/regional differences. Australia, 2002-11. Respondents participating in a triennial survey (aged 12-17 years); 44 897 from urban settings, 23 311 from regional settings. The key outcome measures were past month alcohol use, risky drinking among all students and risky drinking among past week drinkers. For each survey year, students were assigned a postcode-level outlet density (number of licences per 1000 population) for each outlet type (general, on-premise, off-premise, clubs). Interaction terms revealed a significant association between off-premises outlet density and risky drinking among all adolescents in urban (odds ratio = 1.36, 95% confidence interval CI = 1.05-1.75, P < 0.05) but not regional areas. Similarly, club density was associated with the drinking outcomes in urban communities only. General and on-premises density was associated with alcohol use and risky drinking among all adolescents. Higher densities of general, on- and off-premises outlets in an adolescent's immediate neighbourhood are related to increased likelihood of alcohol consumption among all adolescents. The density of licensed clubs is associated more strongly with drinking for urban than for regional adolescents. © 2015 Society for the Study of Addiction.

  2. Wastewater treatment by nanofiltration membranes

    NASA Astrophysics Data System (ADS)

    Mulyanti, R.; Susanto, H.

    2018-03-01

    Lower energy consumption compared to reverse osmosis (RO) and higher rejection compared to ultrafiltration make nanofiltration (NF) membrane get more and more attention for wastewater treatment. NF has become a promising technology not only for treating wastewater but also for reusing water from wastewater. This paper presents various application of NF for wastewater treatments. The factors affecting the performance of NF membranes including operating conditions, feed characteristics and membrane characteristics were discussed. In addition, fouling as a severe problem during NF application is also presented. Further, future prospects and challenges of NF for wastewater treatments are explained.

  3. Spatial panel analyses of alcohol outlets and motor vehicle crashes in California: 1999–2008

    PubMed Central

    Ponicki, William R.; Gruenewald, Paul J.; Remer, Lillian G.

    2014-01-01

    Although past research has linked alcohol outlet density to higher rates of drinking and many related social problems, there is conflicting evidence of density’s association with traffic crashes. An abundance of local alcohol outlets simultaneously encourages drinking and reduces driving distances required to obtain alcohol, leading to an indeterminate expected impact on alcohol-involved crash risk. This study separately investigates the effects of outlet density on (1) the risk of injury crashes relative to population and (2) the likelihood that any given crash is alcohol-involved, as indicated by police reports and single-vehicle nighttime status of crashes. Alcohol outlet density effects are estimated using Bayesian misalignment Poisson analyses of all California ZIP codes over the years 1999–2008. These misalignment models allow panel analysis of ZIP-code data despite frequent redefinition of postal-code boundaries, while also controlling for overdispersion and the effects of spatial autocorrelation. Because models control for overall retail density, estimated alcohol-outlet associations represent the extra effect of retail establishments selling alcohol. The results indicate a number of statistically well-supported associations between retail density and crash behavior, but the implied effects on crash risks are relatively small. Alcohol-serving restaurants have a greater impact on overall crash risks than on the likelihood that those crashes involve alcohol, whereas bars primarily affect the odds that crashes are alcohol-involved. Off-premise outlet density is negatively associated with risks of both crashes and alcohol involvement, while the presence of a tribal casino in a ZIP code is linked to higher odds of police-reported drinking involvement. Alcohol outlets in a given area are found to influence crash risks both locally and in adjacent ZIP codes, and significant spatial autocorrelation also suggests important relationships across geographical units

  4. Contamination of faecal coliforms in ice cubes sampled from food outlets in Kubang Kerian, Kelantan.

    PubMed

    Noor Izani, N J; Zulaikha, A R; Mohamad Noor, M R; Amri, M A; Mahat, N A

    2012-03-01

    The use of ice cubes in beverages is common among patrons of food outlets in Malaysia although its safety for human consumption remains unclear. Hence, this study was designed to determine the presence of faecal coliforms and several useful water physicochemical parameters viz. free residual chlorine concentration, turbidity and pH in ice cubes from 30 randomly selected food outlets in Kubang Kerian, Kelantan. Faecal coliforms were found in ice cubes in 16 (53%) food outlets ranging between 1 CFU/100mL to >50 CFU/ 100mL, while in the remaining 14 (47%) food outlets, in samples of tap water as well as in commercially bottled drinking water, faecal coliforms were not detected. The highest faecal coliform counts of >50 CFU/100mL were observed in 3 (10%) food outlets followed by 11-50 CFU/100mL and 1-10 CFU/100mL in 7 (23%) and 6 (20%) food outlets, respectively. All samples recorded low free residual chlorine concentration (<0.10mg/L) with the pH ranging between 5.5 and 7.3 and turbidity between 0.14-1.76 NTU. Since contamination by faecal coliforms was not detected in 47% of the samples, tap water and commercially bottled drinking water, it was concluded that (1) contamination by faecal coliforms may occur due to improper handling of ice cubes at the food outlets or (2) they may not be the water sources used for making ice cubes. Since low free residual chlorine concentrations were observed (<0.10mg/ L) in all samples as well as in both tap water and commercially bottled drinking water, with the pH ranged between 5.5-7.3, ineffective disinfection of water source as a contributing factor to such high counts of faecal coliforms in ice cubes also could not be ruled out. Therefore, a periodical, yet comprehensive check on the food outlets, including that of ice cube is crucial in ensuring better food and water for human consumption.

  5. The premises is the premise: understanding off- and on-premises alcohol sales outlets to improve environmental alcohol prevention strategies.

    PubMed

    Chinman, Matthew; Burkhart, Q; Ebener, Patricia; Fan, Cha-Chi; Imm, Pamela; Osilla, Karen Chan; Paddock, Susan M; Wright, Annie

    2011-06-01

    Environmental strategies to prevent the misuse of alcohol among youth--e.g., use of public policies to restrict minors' access to alcohol--have been shown to reduce underage drinking. However, implementation of policy changes often requires public and private partnerships. One way to support these partnerships is to better understand the target of many of the environmental strategies, which is the alcohol sales outlet. Knowing more about how off-premises outlets (e.g., liquor and convenience stores) and on-premises outlets (e.g., bars and restaurants) are alike and different could help community-based organizations better tailor, plan, and implement their environmental strategies and strengthen partnerships between the public and commercial sectors. We conducted a survey of managerial or supervisory staff and/or owners of 336 off- and on-premises alcohol outlets in six counties in South Carolina, comparing these two outlet types on their preferences regarding certain alcohol sales practices, beliefs toward underage drinking, alcohol sales practices, and outcomes. Multilevel logistic regression showed that while off- and on-premises outlets did have many similarities, off-premises outlets appear to engage in more practices designed to prevent sales of alcohol to minors than on-premises outlets. The relationship between certain Responsible Beverage Service (RBS) practices and outcomes varied by outlet type. This study furthers the understanding of the differences between off- and on-premises alcohol sales outlets and offers options for increasing and tailoring environmental prevention efforts to specific settings.

  6. The Premises is the Premise: Understanding Off- and On-Premises Alcohol Sales Outlets to Improve Environmental Alcohol Prevention Strategies

    PubMed Central

    Chinman, Matthew; Burkhart, Q; Ebener, Patricia; Fan, Cha-Chi; Imm, Pamela; Osilla, Karen Chan; Paddock, Susan M.; Wright, Patricia Ann

    2017-01-01

    Environmental strategies to prevent the misuse of alcohol among youth—e.g., use of public policies to restrict minors’ access to alcohol—have been shown to reduce underage drinking. However, implementation of policy changes often requires public and private partnerships. One way to support these partnerships is to better understand the target of many of the environmental strategies, which is the alcohol sales outlet. Knowing more about how off-premises outlets (e.g., liquor and convenience stores) and on-premises outlets (e.g., bars and restaurants) are alike and different could help community-based organizations better tailor, plan, and implement their environmental strategies and strengthen partnerships between the public and commercial sectors. We conducted a survey of managerial or supervisory staff and/or owners of 336 off- and on-premises alcohol outlets in six counties in South Carolina, comparing these two outlet types on their preferences regarding certain alcohol sales practices, beliefs toward underage drinking, alcohol sales practices, and outcomes. Multilevel logistic regression showed that while off- and on-premises outlets did have many similarities, off-premises outlets appear to engage in more practices designed to prevent sales of alcohol to minors than on-premises outlets. The relationship between certain Responsible Beverage Service (RBS) practices and outcomes varied by outlet type. This study furthers the understanding of the differences between off- and on-premises alcohol sales outlets and offers options for increasing and tailoring environmental prevention efforts to specific settings. PMID:21373877

  7. Modeling of Greenland outlet glaciers response to future climate change

    NASA Astrophysics Data System (ADS)

    Beckmann, J.

    2017-12-01

    Over the past two decades net mass loss from the Greenland ice sheet (GIS) quadrupled, resulting in 25% of the global mean sea level (GMSL) rise. Increased mass loss of the GIS is caused by enhanced surface melting and speedup of the marine-terminating outlet glaciers. This speedup has been related, among other factors, to enhanced submarine melting, which in turn is caused by warming of the surrounding ocean and by increased subglacial, meltwater discharge. Yet, ice-ocean processes are not properly represented in contemporary Greenland Ice Sheet models used to project future changes in the GIS. In this work, we performed numerical experiments with a one-dimensional plume model coupled to a one-dimensional (depth- and width- integrated) ice flow model for several representative outlet glaciers in Greenland. We investigate the dynamic response of the coupled ice-flow plume model to scenarios of future climate change. In particular, we examine the transient response of the outlet glaciers to projected changes in surface melting, ocean temperature and subglacial discharge. With our modeling approach we quantify the amount of the surface and submarine melting and the resulting retreat and mass loss for each individual glacier for the next 100 years.

  8. Expiry of medicines in supply outlets in Uganda

    PubMed Central

    Nakyanzi, Josephine Katabaazi; Kitutu, Freddy Eric; Oria, Hussein

    2010-01-01

    Abstract Problem The expiry of medicines in the supply chain is a serious threat to the already constrained access to medicines in developing countries. Approach We investigated the extent of, and the main contributing factors to, expiry of medicines in medicine supply outlets in Kampala and Entebbe, Uganda. A cross-sectional survey of six public and 32 private medicine outlets was done using semi-structured questionnaires. Local setting The study area has 19 public medicine outlets (three non-profit wholesalers, 16 hospital stores/pharmacies), 123 private wholesale pharmacies and 173 retail pharmacies, equivalent to about 70% of the country’s pharmaceutical businesses. Our findings indicate that medicines prone to expiry include those used for vertical programmes, donated medicines and those with a slow turnover. Relevant changes Awareness about the threat of expiry of medicines to the delivery of health services has increased. We have adapted training modules to emphasize management of medicine expiry for pharmacy students, pharmacists and other persons handling medicines. Our work has also generated more research interest on medicine expiry in Uganda. Lessons learned Even essential medicines expire in the supply chain in Uganda. Sound coordination is needed between public medicine wholesalers and their clients to harmonize procurement and consumption as well as with vertical programmes to prevent duplicate procurement. Additionally, national medicine regulatory authorities should enforce existing international guidelines to prevent dumping of donated medicine. Medicine selection and quantification should be matched with consumer tastes and prescribing habits. Lean supply and stock rotation should be considered. PMID:20428373

  9. Cold Stress

    MedlinePlus

    ... Publications and Products Programs Contact NIOSH NIOSH COLD STRESS Recommend on Facebook Tweet Share Compartir Workers who ... cold environments may be at risk of cold stress. Extreme cold weather is a dangerous situation that ...

  10. DOES ALCOHOL OUTLET DENSITY MODERATE THE RELATIONSHIP BETWEEN LEVELS OF ALCOHOL USE AND CHILD PHYSICAL ABUSE?

    PubMed Central

    Freisthler, Bridget; Wolf, Jennifer Price

    2016-01-01

    Objectives Parental alcohol use and alcohol outlet density are both associated with child abuse. Guided by alcohol availability theory, this paper examines whether alcohol outlet density moderates the relationship between parental alcohol use and child physical abuse. Methods A general population telephone survey of 3,023 parents or legal guardians 18 years or older was conducted across 50 California cities, while densities of alcohol outlets were measured for by zip code. Data were analyzed via overdispersed multilevel Poisson models. Results Ex-drinkers, light drinkers, and heavy drinkers use physical abuse more often than lifetime abstainers. Moderate drinking was not related to child physical abuse. Proportion of bars was negatively related to frequency of physical abuse. Moderating relationships between alcohol outlet density and drinking categories were found for all drinking patterns. Conclusion Different types of alcohol outlets may be differentially related to drinking patterns, indicating that the interaction of drinking patterns and the drinking environment may place children at greater risk for being physically abused. PMID:27642071

  11. Investigation of the Association Between Alcohol Outlet Density and Alcohol-Related Hospital Admission Rates in England: Study Protocol

    PubMed Central

    Holmes, John; Green, Mark; Strong, Mark; Pearson, Tim; Meier, Petra

    2016-01-01

    Background Availability of alcohol is a major policy issue for governments, and one of the availability factors is the density of alcohol outlets within geographic areas. Objective The aim of this study is to investigate the association between alcohol outlet density and hospital admissions for alcohol-related conditions in a national (English) small area level ecological study. Methods This project will employ ecological correlation and cross-sectional time series study designs to examine spatial and temporal relationships between alcohol outlet density and hospital admissions. Census units to be used in the analysis will include all Lower and Middle Super-Output Areas (LSOAs and MSOAs) in England (53 million total population; 32,482 LSOAs and 6781 MSOAs). LSOAs (approximately 1500 people per LSOA) will support investigation at a fine spatial resolution. Spatio-temporal associations will be investigated using MSOAs (approximately 7500 people per MSOA). The project will use comprehensive coverage data on alcohol outlets in England (from 2003, 2007, 2010, and 2013) from a commercial source, which has estimated that the database includes 98% of all alcohol outlets in England. Alcohol outlets may be classified into two broad groups: on-trade outlets, comprising outlets from which alcohol can be purchased and consumed on the premises (eg, pubs); and off-trade outlets, in which alcohol can be purchased but not consumed on the premises (eg, off-licenses). In the 2010 dataset, there are 132,989 on-trade and 51,975 off-trade outlets. The longitudinal data series will allow us to examine associations between changes in outlet density and changes in hospital admission rates. The project will use anonymized data on alcohol-related hospital admissions in England from 2003 to 2013 and investigate associations with acute (eg, admissions for injuries) and chronic (eg, admissions for alcoholic liver disease) harms. The investigation will include the examination of conditions that

  12. 7 CFR 989.24a - Non-normal outlets.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 8 2014-01-01 2014-01-01 false Non-normal outlets. 989.24a Section 989.24a Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (MARKETING AGREEMENTS AND ORDERS; FRUITS, VEGETABLES, NUTS), DEPARTMENT OF AGRICULTURE RAISINS PRODUCED FROM GRAPES...

  13. 7 CFR 989.24a - Non-normal outlets.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Non-normal outlets. 989.24a Section 989.24a Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements and Orders; Fruits, Vegetables, Nuts), DEPARTMENT OF AGRICULTURE RAISINS PRODUCED FROM GRAPES...

  14. 7 CFR 989.24a - Non-normal outlets.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 8 2013-01-01 2013-01-01 false Non-normal outlets. 989.24a Section 989.24a Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (MARKETING AGREEMENTS AND ORDERS; FRUITS, VEGETABLES, NUTS), DEPARTMENT OF AGRICULTURE RAISINS PRODUCED FROM GRAPES...

  15. 7 CFR 989.24a - Non-normal outlets.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 8 2012-01-01 2012-01-01 false Non-normal outlets. 989.24a Section 989.24a Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements and Orders; Fruits, Vegetables, Nuts), DEPARTMENT OF AGRICULTURE RAISINS PRODUCED FROM GRAPES...

  16. Hypothermic general cold adaptation induced by local cold acclimation.

    PubMed

    Savourey, G; Barnavol, B; Caravel, J P; Feuerstein, C; Bittel, J H

    1996-01-01

    To study relationships between local cold adaptation of the lower limbs and general cold adaptation, eight subjects were submitted both to a cold foot test (CFT, 5 degrees C water immersion, 5 min) and to a whole-body standard cold air test (SCAT, 1 degree C, 2 h, nude at rest) before and after a local cold acclimation (LCA) of the lower limbs effected by repeated cold water immersions. The LCA induced a local cold adaptation confirmed by higher skin temperatures of the lower limbs during CFT and a hypothermic insulative general cold adaptation (decreased rectal temperature and mean skin temperature P < 0.05) without a change either in metabolic heat production or in lower limb skin temperatures during SCAT after LCA. It was concluded that local cold adaptation was related to the habituation process confirmed by decreased plasma concentrations of noradrenaline (NA) during LCA (P < 0.05). However, the hypothermic insulative general cold adaptation was unrelated either to local cold adaptation or to the habituation process, because an increased NA during SCAT after LCA (P < 0.05) was observed but was rather related to a "T3 polar syndrome" occurring during LCA.

  17. Does neighborhood fast-food outlet exposure amplify inequalities in diet and obesity? A cross-sectional study.

    PubMed

    Burgoine, Thomas; Forouhi, Nita G; Griffin, Simon J; Brage, Søren; Wareham, Nicholas J; Monsivais, Pablo

    2016-06-01

    Greater exposures to fast-food outlets and lower levels of education are independently associated with less healthy diets and obesity. Little is known about the interplay between these environmental and individual factors. The purpose of this study was to test whether observed differences in fast-food consumption and obesity by fast-food outlet exposure are moderated by educational attainment. In a population-based cohort of 5958 adults aged 29-62 y in Cambridgeshire, United Kingdom, we used educational attainment-stratified regression models to estimate the food-frequency questionnaire-derived consumption of energy-dense "fast foods" (g/d) typically sold in fast-food restaurants and measured body mass index (BMI; in kg/m(2)) across geographic information system-derived home and work fast-food exposure quartiles. We used logistic regression to estimate the odds of obesity (BMI ≥30) and calculated relative excess risk due to interaction (RERI) on an additive scale. Participant data were collected during 2005-2013 and analyzed in 2015. Greater fast-food consumption, BMI, and odds of obesity were associated with greater fast-food outlet exposure and a lower educational level. Fast-food consumption and BMI were significantly different across education groups at all levels of fast-food outlet exposure (P < 0.05). High fast-food outlet exposure amplified differences in fast-food consumption across levels of education. The relation between fast-food outlet exposure and obesity was only significant among those who were least educated (OR: 2.05; 95% CI: 1.08, 3.87; RERI = 0.88), which suggested a positive additive interaction between education and fast-food outlet exposure. These findings suggest that efforts to improve diets and health through neighborhood-level fast-food outlet regulation might be effective across socioeconomic groups and may serve to reduce observed socioeconomic inequalities in diet and obesity.

  18. Water Pollution: Part I, Municipal Wastewaters; Part II, Industrial Wastewaters.

    ERIC Educational Resources Information Center

    Fowler, K. E. M.

    This publication is an annotated bibliography of municipal and industrial wastewater literature. This publication consists of two parts plus appendices. Part one is entitled Municipal Wastewaters and includes publications in such areas as health effects of polluted waters, federal policy and legislation, biology and chemistry of polluted water,…

  19. Thoracic outlet syndrome: definition, aetiological factors, diagnosis, management and occupational impact.

    PubMed

    Laulan, Jacky; Fouquet, Bernard; Rodaix, Camille; Jauffret, Penelope; Roquelaure, Yves; Descatha, Alexis

    2011-09-01

    Thoracic outlet syndrome is a controversial cause of neck and shoulder pain due to complex mechanisms involving muscular dysfunction and nerve compression. Although management of thoracic outlet syndrome must be based on a multidisciplinary approach, physicians and occupational therapist should be familiar with the principles of diagnosis and treatment. The purpose of this article is to review the definitions, diagnosis and management of this syndrome. A particular emphasis was described on the links between the workplace and the individual in the pathogenesis, prevalence in the workforce and the course of this disease.

  20. Human viral pathogens are pervasive in wastewater treatment center aerosols.

    PubMed

    Brisebois, Evelyne; Veillette, Marc; Dion-Dupont, Vanessa; Lavoie, Jacques; Corbeil, Jacques; Culley, Alexander; Duchaine, Caroline

    2018-05-01

    Wastewater treatment center (WTC) workers may be vulnerable to diseases caused by viruses, such as the common cold, influenza and gastro-intestinal infections. Although there is a substantial body of literature characterizing the microbial community found in wastewater, only a few studies have characterized the viral component of WTC aerosols, despite the fact that most diseases affecting WTC workers are of viral origin and that some of these viruses are transmitted through the air. In this study, we evaluated in four WTCs the presence of 11 viral pathogens of particular concern in this milieu and used a metagenomic approach to characterize the total viral community in the air of one of those WTCs. The presence of viruses in aerosols in different locations of individual WTCs was evaluated and the results obtained with four commonly used air samplers were compared. We detected four of the eleven viruses tested, including human adenovirus (hAdV), rotavirus, hepatitis A virus (HAV) and Herpes Simplex virus type 1 (HSV1). The results of the metagenomic assay uncovered very few viral RNA sequences in WTC aerosols, however sequences from human DNA viruses were in much greater relative abundance. Copyright © 2017. Published by Elsevier B.V.

  1. Occurrence of pharmaceutical compounds in wastewater and sludge from wastewater treatment plants: removal and ecotoxicological impact of wastewater discharges and sludge disposal.

    PubMed

    Martín, J; Camacho-Muñoz, D; Santos, J L; Aparicio, I; Alonso, E

    2012-11-15

    The occurrence of sixteen pharmaceutically active compounds in influent and effluent wastewater and in primary, secondary and digested sludge in one-year period has been evaluated. Solid-water partition coefficients (Kd) were calculated to evaluate the efficiency of removal of these compounds from wastewater by sorption onto sludge. The ecotoxicological risk to aquatic and terrestrial ecosystems, due to wastewater discharges to the receiving streams and to the application of digested sludge as fertilizer onto soils, was also evaluated. Twelve of the pharmaceuticals were detected in wastewater at mean concentrations from 0.1 to 32 μg/L. All the compounds found in wastewater were also found in sewage sludge, except diclofenac, at mean concentrations from 8.1 to 2206 μg/kg dm. Ibuprofen, salicylic acid, gemfibrozil and caffeine were the compounds at the highest concentrations. LogKd values were between 1.17 (naproxen) and 3.48 (carbamazepine). The highest ecotoxicological risk in effluent wastewater and digested sludge is due to ibuprofen (risk quotient (RQ): 3.2 and 4.4, respectively), 17α-ethinylestradiol (RQ: 12 and 22, respectively) and 17β-estradiol (RQ: 12 and 359, respectively). Ecotoxicological risk after wastewater discharge and sludge disposal is limited to the presence of 17β-estradiol in digested-sludge amended soil (RQ: 2.7). Copyright © 2012 Elsevier B.V. All rights reserved.

  2. 40 CFR 63.453 - Monitoring requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... process wastewater feed rate; (2) The steam feed rate; and (3) The process wastewater column feed...: (A) Composite daily sample of outlet soluble BOD5 concentration to monitor for maximum daily and...

  3. 40 CFR 63.453 - Monitoring requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... process wastewater feed rate; (2) The steam feed rate; and (3) The process wastewater column feed...: (A) Composite daily sample of outlet soluble BOD5 concentration to monitor for maximum daily and...

  4. 40 CFR 63.453 - Monitoring requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... process wastewater feed rate; (2) The steam feed rate; and (3) The process wastewater column feed...: (A) Composite daily sample of outlet soluble BOD5 concentration to monitor for maximum daily and...

  5. Research on the enhancement of biological nitrogen removal at low temperatures from ammonium-rich wastewater by the bio-electrocoagulation technology in lab-scale systems, pilot-scale systems and a full-scale industrial wastewater treatment plant.

    PubMed

    Li, Liang; Qian, Guangsheng; Ye, Linlin; Hu, Xiaomin; Yu, Xin; Lyu, Weijian

    2018-09-01

    In cold areas, nitrogen removal performance of wastewater treatment plants (WWTP) declines greatly in winter. This paper systematically describes the enhancement effect of a periodic reverse electrocoagulation technology on biological nitrogen removal at low temperatures. The study showed that in the lab-scale systems, the electrocoagulation technology improved the biomass amount, enzyme activity and the amount of nitrogen removal bacteria (Nitrosomonas, Nitrobacter, Paracoccus, Thauera and Enterobacter). This enhanced nitrification and denitrification of activated sludge at low temperatures. In the pilot-scale systems, the electrocoagulation technology increased the relative abundance of cold-adapted microorganisms (Luteimonas and Trueperaceae) at low temperatures. In a full-scale industrial WWTP, comparison of data from winter 2015 and winter 2016 showed that effluent chemical oxygen demand (COD), NH 4 + -N, and NO 3 - -N reduced by 10.37, 3.84, and 136.43 t, respectively, throughout the winter, after installation of electrocoagulation devices. These results suggest that the electrocoagulation technology is able to improve the performance of activated sludge under low-temperature conditions. This technology provides a new way for upgrading of the performance of WWTPs in cold areas. Copyright © 2018 Elsevier Ltd. All rights reserved.

  6. 40 CFR Table 6 to Subpart Ggg of... - Wastewater-Compliance Options for Wastewater Tanks

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 12 2013-07-01 2013-07-01 false Wastewater-Compliance Options for Wastewater Tanks 6 Table 6 to Subpart GGG of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION.... GGG, Table 6 Table 6 to Subpart GGG of Part 63—Wastewater—Compliance Options for Wastewater Tanks...

  7. 40 CFR Table 6 to Subpart Ggg of... - Wastewater-Compliance Options for Wastewater Tanks

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 12 2014-07-01 2014-07-01 false Wastewater-Compliance Options for Wastewater Tanks 6 Table 6 to Subpart GGG of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION.... GGG, Table 6 Table 6 to Subpart GGG of Part 63—Wastewater—Compliance Options for Wastewater Tanks...

  8. Food outlet availability, deprivation and obesity in a multi-ethnic sample of pregnant women in Bradford, UK.

    PubMed

    Fraser, L K; Edwards, K L; Tominitz, M; Clarke, G P; Hill, A J

    2012-09-01

    The obesogenic environment model would suggest that increased availability or access to energy dense foods which are high in saturated fat may be related to obesity. The association between food outlet location, deprivation, weight status and ethnicity was analysed using individual level data on a sample of 1198 pregnant women in the UK Born in Bradford cohort using geographic information systems (GIS) methodology. In the non South Asian group 24% were obese as were 17% of the South Asian group (BMI > 30). Food outlet identification methods revealed 886 outlets that were allocated into 5 categories of food shops. More than 95% of all participants lived within 500 m of a fast food outlet. Women in higher areas of deprivation had greater access to fast food outlets and to other forms of food shops. Contrary to hypotheses, there was a negative association between BMI and fast food outlet density in close (250 m) proximity in the South Asian group. Overall, these women had greater access to all food stores including fast food outlets compared to the non South Asian group. The stronger association between area level deprivation and fast food density than with area level deprivation and obesity argues for more detailed accounts of the obesogenic environment that include measures of individual behaviour. Copyright © 2012 Elsevier Ltd. All rights reserved.

  9. 40 CFR 63.3555 - How do I determine the outlet THC emissions and add-on control device emission destruction or...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 12 2010-07-01 2010-07-01 true How do I determine the outlet THC.../outlet Concentration Option § 63.3555 How do I determine the outlet THC emissions and add-on control... section to determine either the outlet THC emissions or add-on control device emission destruction or...

  10. 40 CFR 63.3555 - How do I determine the outlet THC emissions and add-on control device emission destruction or...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 13 2013-07-01 2012-07-01 true How do I determine the outlet THC... Control Efficiency/outlet Concentration Option § 63.3555 How do I determine the outlet THC emissions and... methods in this section to determine either the outlet THC emissions or add-on control device emission...

  11. 40 CFR 63.3555 - How do I determine the outlet THC emissions and add-on control device emission destruction or...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 13 2014-07-01 2014-07-01 false How do I determine the outlet THC... Control Efficiency/outlet Concentration Option § 63.3555 How do I determine the outlet THC emissions and... methods in this section to determine either the outlet THC emissions or add-on control device emission...

  12. 40 CFR 63.3555 - How do I determine the outlet THC emissions and add-on control device emission destruction or...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 12 2011-07-01 2009-07-01 true How do I determine the outlet THC.../outlet Concentration Option § 63.3555 How do I determine the outlet THC emissions and add-on control... section to determine either the outlet THC emissions or add-on control device emission destruction or...

  13. 40 CFR 63.3555 - How do I determine the outlet THC emissions and add-on control device emission destruction or...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 13 2012-07-01 2012-07-01 false How do I determine the outlet THC... Control Efficiency/outlet Concentration Option § 63.3555 How do I determine the outlet THC emissions and... methods in this section to determine either the outlet THC emissions or add-on control device emission...

  14. The density of alcohol outlets and adolescent alcohol consumption: An Australian longitudinal analysis.

    PubMed

    Rowland, B; Evans-Whipp, Tracy; Hemphill, Sheryl; Leung, Rachel; Livingston, M; Toumbourou, J W

    2016-01-01

    Higher density of alcohol outlets has been linked to increased levels of adolescent alcohol-related behaviour. Research to date has been cross-sectional. A longitudinal design using two waves of annual survey data from the Australian arm of the International Youth Development Study was used. The sample comprised 2835 individuals with average age at wave 2 of 14 years (SD=1.67; range=11-17 years). GSEM was used to examine how absolute levels of alcohol outlet density was associated with student-reported alcohol use one year later, while controlling for prior alcohol use, risk factors at wave one and changes in density over the 2 years. Adolescents' perception of alcohol availability and friends' alcohol use were tested as potential mediators of the association between alcohol outlet density and adolescent alcohol use. Elasticity modelling identified a 10% increase in overall density at wave one was associated with an approximately 17% increase in odds of adolescent alcohol consumption at wave two. Living in areas with a higher density of outlets was associated with a statistically significant increase in the likelihood of adolescents developing early age alcohol consumption. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Flow rate analysis of wastewater inside reactor tanks on tofu wastewater treatment plant

    NASA Astrophysics Data System (ADS)

    Mamat; Sintawardani, N.; Astuti, J. T.; Nilawati, D.; Wulan, D. R.; Muchlis; Sriwuryandari, L.; Sembiring, T.; Jern, N. W.

    2017-03-01

    The research aimed to analyse the flow rate of the wastewater inside reactor tanks which were placed a number of bamboo cutting. The resistance of wastewater flow inside reactor tanks might not be occurred and produce biogas fuel optimally. Wastewater from eleven tofu factories was treated by multi-stages anaerobic process to reduce its organic pollutant and produce biogas. Biogas plant has six reactor tanks of which its capacity for waste water and gas dome was 18 m3 and 4.5 m3, respectively. Wastewater was pumped from collecting ponds to reactors by either serial or parallel way. Maximum pump capacity, head, and electrical motor power was 5m3/h, 50m, and 0.75HP, consecutively. Maximum pressure of biogas inside the reactor tanks was 55 mbar higher than atmosphere pressure. A number of 1,400 pieces of cutting bamboo at 50-60 mm diameter and 100 mm length were used as bacteria growth media inside each reactor tank, covering around 14,287 m2 bamboo area, and cross section area of inner reactor was 4,9 m2. In each reactor, a 6 inches PVC pipe was installed vertically as channel. When channels inside reactor were opened, flow rate of wastewater was 6x10-1 L.sec-1. Contrary, when channels were closed on the upper part, wastewater flow inside the first reactor affected and increased gas dome. Initially, wastewater flowed into each reactor by a gravity mode with head difference between the second and third reactor was 15x10-2m. However, head loss at the second reactor was equal to the third reactor by 8,422 x 10-4m. As result, wastewater flow at the second and third reactors were stagnant. To overcome the problem pump in each reactor should be installed in serial mode. In order to reach the output from the first reactor and the others would be equal, and biogas space was not filled by wastewater, therefore biogas production will be optimum.

  16. Communicating Ebola through social media and electronic news media outlets: A cross-sectional study.

    PubMed

    Househ, Mowafa

    2016-09-01

    Social media and electronic news media activity are an important source of information for the general public. Yet, there is a dearth of research exploring the use of Twitter and electronic news outlets during significant worldly events such as the recent Ebola Virus scare. The purpose of this article is to investigate the use of Twitter and electronic news media outlets in communicating Ebola Virus information. A cross-sectional survey of Twitter data and Google News Trend data from 30 September till 29 October, 2014 was conducted. Between 30 September and 29 October, there were approximately 26 million tweets (25,925,152) that contained the word Ebola. The highest number of correlated activity for Twitter and electronic news outlets occurred on 16 October 2014. Other important peaks in Twitter data occurred on 1 October, 6 October, 8 October, and 12 October, 2014. The main influencers of the Twitter feeds were news media outlets. The study reveals a relationship between electronic news media publishing and Twitter activity around significant events such as Ebola. Healthcare organizations should take advantage of the relationship between electronic news media and trending events on social media sites such as Twitter and should work on developing social media campaigns in co-operation with leading electronic news media outlets (e.g. CNN, Yahoo, Reuters) that can have an influence on social media activity. © The Author(s) 2015.

  17. Assessing biodiesel quality parameters for wastewater grown Chlorella sp.

    PubMed

    Bagul, Samadhan Yuvraj; K Bharti, Randhir; Dhar, Dolly Wattal

    2017-07-01

    Microalgae are reported as the efficient source of renewable biodiesel which should be able to meet the global demand of transport fuels. Present study is focused on assessment of wastewater grown indigenous microalga Chlorella sp. for fuel quality parameters. This was successfully grown in secondary treated waste water diluted with tap water (25% dilution) in glass house. The microalga showed a dry weight of 0.849 g L -1 with lipid content of 27.1% on dry weight basis on 21st day of incubation. After transesterification, the yield of fatty acid methyl ester was 80.64% with major fatty acids as palmitic, linoleic, oleic and linolenic. The physical parameters predicted from empirical equations in the biodiesel showed cetane number as 56.5, iodine value of 75.5 g I 2 100 g -1 , high heating value 40.1 MJ kg -1 , flash point 135 °C, kinematic viscosity 4.05 mm 2 s -1 with density of 0.86 g cm 3 and cold filter plugging point as 0.7 °C. Fourier transform infra-red (FTIR), 1 H, 13 C NMR spectrum confirmed the chemical nature of biodiesel. The results indicated that the quality of biodiesel was almost as per the criterion of ASTM standards; hence, wastewater grown Chlorella sp. can be used as a promising strain for biodiesel production.

  18. Future sea-level rise from Greenland's main outlet glaciers in a warming climate.

    PubMed

    Nick, Faezeh M; Vieli, Andreas; Andersen, Morten Langer; Joughin, Ian; Payne, Antony; Edwards, Tamsin L; Pattyn, Frank; van de Wal, Roderik S W

    2013-05-09

    Over the past decade, ice loss from the Greenland Ice Sheet increased as a result of both increased surface melting and ice discharge to the ocean. The latter is controlled by the acceleration of ice flow and subsequent thinning of fast-flowing marine-terminating outlet glaciers. Quantifying the future dynamic contribution of such glaciers to sea-level rise (SLR) remains a major challenge because outlet glacier dynamics are poorly understood. Here we present a glacier flow model that includes a fully dynamic treatment of marine termini. We use this model to simulate behaviour of four major marine-terminating outlet glaciers, which collectively drain about 22 per cent of the Greenland Ice Sheet. Using atmospheric and oceanic forcing from a mid-range future warming scenario that predicts warming by 2.8 degrees Celsius by 2100, we project a contribution of 19 to 30 millimetres to SLR from these glaciers by 2200. This contribution is largely (80 per cent) dynamic in origin and is caused by several episodic retreats past overdeepenings in outlet glacier troughs. After initial increases, however, dynamic losses from these four outlets remain relatively constant and contribute to SLR individually at rates of about 0.01 to 0.06 millimetres per year. These rates correspond to ice fluxes that are less than twice those of the late 1990s, well below previous upper bounds. For a more extreme future warming scenario (warming by 4.5 degrees Celsius by 2100), the projected losses increase by more than 50 per cent, producing a cumulative SLR of 29 to 49 millimetres by 2200.

  19. 40 CFR 63.1433 - Wastewater provisions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 12 2013-07-01 2013-07-01 false Wastewater provisions. 63.1433 Section... Wastewater provisions. (a) Process wastewater. Except as specified in paragraph (c) of this section, the owner or operator of each affected source shall comply with the HON wastewater requirements in §§ 63.132...

  20. Contoured tank outlets for draining of cylindrical tanks in low-gravity environment. [Lewis Research Center Zero Gravity Facility

    NASA Technical Reports Server (NTRS)

    Symons, E. P.

    1979-01-01

    An analysis is presented for defining the outlet contour of a hemispherical-bottomed cylindrical tank that will prevent vapor ingestion when the tank is drained. The analysis was used to design two small-scale tanks that were fabricated and then tested in a low gravity environment. The draining performance of the tanks was compared with that for a tank with a conventional outlet having a constant circular cross-sectional area, under identical conditions. Even when drained at off-design conditions, the contoured tank had less liquid residuals at vapor ingestion than the conventional outlet tank. Effects of outflow rate, gravitational environment, and fluid properties on the outlet contour are discussed. Two potential applications of outlet contouring are also presented and discussed.

  1. 7 CFR 929.104 - Outlets for excess cranberries.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 8 2013-01-01 2013-01-01 false Outlets for excess cranberries. 929.104 Section 929... SERVICE (MARKETING AGREEMENTS AND ORDERS; FRUITS, VEGETABLES, NUTS), DEPARTMENT OF AGRICULTURE CRANBERRIES... excess cranberries. (a) In accordance with § 929.61, excess cranberries may be disposed of only in the...

  2. 7 CFR 929.104 - Outlets for excess cranberries.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 8 2014-01-01 2014-01-01 false Outlets for excess cranberries. 929.104 Section 929... SERVICE (MARKETING AGREEMENTS AND ORDERS; FRUITS, VEGETABLES, NUTS), DEPARTMENT OF AGRICULTURE CRANBERRIES... excess cranberries. (a) In accordance with § 929.61, excess cranberries may be disposed of only in the...

  3. 7 CFR 929.104 - Outlets for excess cranberries.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 8 2012-01-01 2012-01-01 false Outlets for excess cranberries. 929.104 Section 929... SERVICE (Marketing Agreements and Orders; Fruits, Vegetables, Nuts), DEPARTMENT OF AGRICULTURE CRANBERRIES... excess cranberries. (a) In accordance with § 929.61, excess cranberries may be disposed of only in the...

  4. 7 CFR 929.104 - Outlets for excess cranberries.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 8 2011-01-01 2011-01-01 false Outlets for excess cranberries. 929.104 Section 929... SERVICE (Marketing Agreements and Orders; Fruits, Vegetables, Nuts), DEPARTMENT OF AGRICULTURE CRANBERRIES... excess cranberries. (a) In accordance with § 929.61, excess cranberries may be disposed of only in the...

  5. Marine carbohydrates of wastewater treatment.

    PubMed

    Sudha, Prasad N; Gomathi, Thandapani; Vinodhini, P Angelin; Nasreen, K

    2014-01-01

    Our natural heritage (rivers, seas, and oceans) has been exploited, mistreated, and contaminated because of industrialization, globalization, population growth, urbanization with increased wealth, and more extravagant lifestyles. The scenario gets worse when the effluents or contaminants are discharged directly. So wastewater treatment is a very important and necessary in nowadays to purify wastewater before it enters a body of natural water, or it is applied to the land, or it is reused. Various methods are available for treating wastewater but with many disadvantages. Recently, numerous approaches have been studied for the development of cheaper and more effective technologies, both to decrease the amount of wastewater produced and to improve the quality of the treated effluent. Biosorption is an emerging technology, which uses natural materials as adsorbents for wastewater treatment. Low-cost adsorbents of polysaccharide-based materials obtained from marine, such as chitin, chitosan, alginate, agar, and carrageenan, are acting as rescue for wastewater treatment. This chapter reviews the treatment of wastewater up to the present time using marine polysaccharides and its derivatives. Special attention is paid to the advantages of the natural adsorbents, which are a wonderful gift for human survival. © 2014 Elsevier Inc. All rights reserved.

  6. Scenedesmus obliquus in poultry wastewater bioremediation.

    PubMed

    Oliveira, Ana Cristina; Barata, Ana; Batista, Ana P; Gouveia, Luísa

    2018-06-18

    Wastewater biological treatment with microalgae can be an effective technology, removing nutrients and other contaminants while reducing chemical oxygen demand. This can be particularly interesting for the meat producing industry which produces large volumes of wastewater from the slaughtering of animals and cleaning of their facilities. The main purpose of this research was the treatment of poultry wastewater using Scenedesmus obliquus in an economical and environmentally sustainable way. Two wastewaters were collected from a Portuguese poultry slaughterhouse (poultry raw - PR and poultry flocculated - PF) and the bioremediation was evaluated. The performance of microalga biomass growth and biochemical composition were assessed for two illumination sources (fluorescent vs LEDs). S. obliquus achieved positive results when grown in highly contaminated agro-industrial wastewater from the poultry industry, independently of the light source. The wastewater bioremediation revealed results higher than 97% for both ammonium and phosphate removal efficiency, for a cultivation time of 13 days. The saponifiable matter obtained from the biomass of the microalga cultures was, on average, 11% and 27% (m/m alga ) with PR and PF wastewater, respectively. In opposition, higher sugar content was obtained from microalgae biomass grown in PR wastewater (average 34% m/m alga ) in comparison to PF wastewater (average 23% m/m alga ), independently of the illumination source. Therefore, biomass obtained with PR wastewater will be more appropriate as a raw material for bioethanol/biohydrogen production (higher sugar content) while biomass produced in PF wastewater will have a similar potential as feedstock for both biodiesel and bioethanol/biohydrogen production (similar lipid and sugar content).

  7. Metal halogen battery system with multiple outlet nozzle for hydrate

    DOEpatents

    Bjorkman, Jr., Harry K.

    1983-06-21

    A metal halogen battery system, including at least one cell having a positive electrode and a negative electrode contacted by aqueous electrolyte containing the material of said metal and halogen, store means whereby halogen hydrate is formed and stored as part of an aqueous material, means for circulating electrolyte through the cell and to the store means, and conduit means for transmitting halogen gas formed in the cell to a hydrate former whereby the hydrate is formed in association with the store means, said store means being constructed in the form of a container which includes a filter means, said filter means being inoperative to separate the hydrate formed from the electrolyte, said system having, a hydrate former pump means associated with the store means and being operative to intermix halogen gas with aqueous electrolyte to form halogen hydrate, said hydrate former means including, multiple outlet nozzle means connected with the outlet side of said pump means and being operative to minimize plugging, said nozzle means being comprised of at least one divider means which is generally perpendicular to the rotational axes of gears within the pump means, said divider means acting to divide the flow from the pump means into multiple outlet flow paths.

  8. 40 CFR 63.1256 - Standards: Wastewater.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Mg/yr. (B) The wastewater stream contains partially soluble and/or soluble HAP compounds at an annual... wastewater from the PMPU exceeds 0.25 Mg/yr. (C) The wastewater stream contains partially soluble and/or... soluble and/or soluble HAP load in all wastewater from the affected source is greater than 1 Mg/yr. (D...

  9. 40 CFR 63.1256 - Standards: Wastewater.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Mg/yr. (B) The wastewater stream contains partially soluble and/or soluble HAP compounds at an annual... wastewater from the PMPU exceeds 0.25 Mg/yr. (C) The wastewater stream contains partially soluble and/or... soluble and/or soluble HAP load in all wastewater from the affected source is greater than 1 Mg/yr. (D...

  10. Influence of seasonality and vegetation on the attenuation of emerging contaminants in wastewater effluent-dominated streams. A preliminary study.

    PubMed

    Matamoros, Víctor; Rodríguez, Yolanda

    2017-11-01

    Treated wastewater from small communities is discharged into rivers or streams with a high biodiversity value. This is particularly important in Mediterranean countries, where most of the streams are dry almost all year round. This preliminary study assessed the occurrence and attenuation of 23 emerging contaminants (ECs) in 4 wastewater-dominated streams in which treated wastewater accounted for the entire stream flow. The concentration of ECs was monitored in the warm and cold seasons in the wastewater treatment plant (WWTP) effluent and at 6 downstream locations. The concentration of ECs in the WWTP effluents ranged from undetected to 12 μg L -1 . The attenuation of ECs 1 km downstream ranged from no removal to up to 80% (48% on average). The half-lives of ECs in the 4 streams ranged from 0.4 to 20 h (3.9 ± 3.5 h on average). Compounds such as benzodiazepine drugs and flame retardants were the most recalcitrant (half-lives >5 h). The highest attenuation of ECs and ammonia was observed in the stream completely covered by vegetation. The cumulative hazardous quotient 1 km downstream was reduced on average by more than 60%. Therefore, the results suggest that both seasonality and vegetation play an important role in in-stream attenuation of ECs. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. An ecological analysis of alcohol-outlet density and campus-reported violence at 32 U.S. colleges.

    PubMed

    Scribner, Richard A; Mason, Karen E; Simonsen, Neal R; Theall, Katherine; Chotalia, Jigar; Johnson, Sandy; Schneider, Shari Kessel; DeJong, William

    2010-03-01

    The purpose of this study was to assess the relationships among campus violence, student drinking levels, and the physical availability of alcohol at off-campus outlets in a multisite design. An ecological analysis of on-campus violence was conducted at 32 U.S. colleges. Dependent variables included campus-reported rates of rape, robbery, assault, and burglary obtained from a U.S. Department of Education online database for the years 2000-2004. Measures of student alcohol use and demographics were obtained from student surveys conducted for the Social Norms Marketing Research Project from 2000 to 2004. Measures of alcohol-outlet density within 3 miles of each campus were obtained from state alcohol-licensing authorities for 2004. Both on- and off-premise alcohol-outlet densities were associated with the campus rape-offense rate but not with the assault or robbery rates. Student drinking level was associated with both campus rape and assault rates but not with the campus robbery rate. The apparent effect of on-premise outlet density on campus rape-offense rates was reduced when student drinking level was included in the model, suggesting that the effect of on-premise outlet density may be mediated by student drinking level. Separate analyses revealed a similar mediational role for off-premise outlet density. These findings demonstrate that there is a campus-level association between sexual violence and the campus-community alcohol environment.

  12. The Cartridge Theory: a description of the functioning of horizontal subsurface flow constructed wetlands for wastewater treatment, based on modelling results.

    PubMed

    Samsó, Roger; García, Joan

    2014-03-01

    Despite the fact that horizontal subsurface flow constructed wetlands have been in operation for several decades now, there is still no clear understanding of some of their most basic internal functioning patterns. To fill this knowledge gap, on this paper we present what we call "The Cartridge Theory". This theory was derived from simulation results obtained with the BIO_PORE model and explains the functioning of urban wastewater treatment wetlands based on the interaction between bacterial communities and the accumulated solids leading to clogging. In this paper we start by discussing some changes applied to the biokinetic model implemented in BIO_PORE (CWM1) so that the growth of bacterial communities is consistent with a well-known population dynamics models. This discussion, combined with simulation results for a pilot wetland system, led to the introduction of "The Cartridge Theory", which states that the granular media of horizontal subsurface flow wetlands can be assimilated to a generic cartridge which is progressively consumed (clogged) with inert solids from inlet to outlet. Simulations also revealed that bacterial communities are poorly distributed within the system and that their location is not static but changes over time, moving towards the outlet as a consequence of the progressive clogging of the granular media. According to these findings, the life-span of constructed wetlands corresponds to the time when bacterial communities are pushed as much towards the outlet that their biomass is not anymore sufficient to remove the desirable proportion of the influent pollutants. Copyright © 2013 Elsevier B.V. All rights reserved.

  13. Statistical Approaches Used to Assess the Equity of Access to Food Outlets: A Systematic Review

    PubMed Central

    Lamb, Karen E.; Thornton, Lukar E.; Cerin, Ester; Ball, Kylie

    2015-01-01

    Background Inequalities in eating behaviours are often linked to the types of food retailers accessible in neighbourhood environments. Numerous studies have aimed to identify if access to healthy and unhealthy food retailers is socioeconomically patterned across neighbourhoods, and thus a potential risk factor for dietary inequalities. Existing reviews have examined differences between methodologies, particularly focussing on neighbourhood and food outlet access measure definitions. However, no review has informatively discussed the suitability of the statistical methodologies employed; a key issue determining the validity of study findings. Our aim was to examine the suitability of statistical approaches adopted in these analyses. Methods Searches were conducted for articles published from 2000–2014. Eligible studies included objective measures of the neighbourhood food environment and neighbourhood-level socio-economic status, with a statistical analysis of the association between food outlet access and socio-economic status. Results Fifty-four papers were included. Outlet accessibility was typically defined as the distance to the nearest outlet from the neighbourhood centroid, or as the number of food outlets within a neighbourhood (or buffer). To assess if these measures were linked to neighbourhood disadvantage, common statistical methods included ANOVA, correlation, and Poisson or negative binomial regression. Although all studies involved spatial data, few considered spatial analysis techniques or spatial autocorrelation. Conclusions With advances in GIS software, sophisticated measures of neighbourhood outlet accessibility can be considered. However, approaches to statistical analysis often appear less sophisticated. Care should be taken to consider assumptions underlying the analysis and the possibility of spatially correlated residuals which could affect the results. PMID:29546115

  14. Surf zone entrainment, along-shore transport, and human health implications of pollution from tidal outlets

    NASA Astrophysics Data System (ADS)

    Grant, S. B.; Kim, J. H.; Jones, B. H.; Jenkins, S. A.; Wasyl, J.; Cudaback, C.

    2005-10-01

    Field experiments and modeling studies were carried out to characterize the surf zone entrainment and along-shore transport of pollution from two tidal outlets that drain into Huntington Beach and Newport Beach, popular public beaches in southern California. The surf zone entrainment and near-shore transport of pollutants from these tidal outlets appears to be controlled by prevailing wave conditions and coastal currents, and fine-scale features of the flow field around the outlets. An analysis of data from dye experiments and fecal indicator bacteria monitoring studies reveals that the along-shore flux of surf zone water is at least 50 to 300 times larger than the cross-shore flux of surf zone water. As a result, pollutants entrained in the surf zone hug the shore, where they travel significant distances parallel to the beach before diluting to extinction. Under the assumption that all surf zone pollution at Huntington Beach originates from two tidal outlets, the Santa Ana River and Talbert Marsh outlets, models of mass and momentum transport in the surf zone approximately capture the observed tidal phasing and magnitude of certain fecal indicator bacteria groups (total coliform) but not others (Escherichia coli and enterococci), implying the existence of multiple sources of, and/or multiple transport pathways for, fecal pollution at this site. The intersection of human recreation and near-shore pollution pathways implies that, from a human health perspective, special care should be taken to reduce the discharge of harmful pollutants from land-side sources of surface water runoff, such as tidal outlets and storm drains.

  15. The Impact of the Tobacco Retail Outlet Environment on Adult Cessation and Differences by Neighborhood Poverty

    PubMed Central

    Anesetti-Rothermel, Andrew; Pearson, Jennifer L.; Xiao, Haijun; Vallone, Donna; Kirchner, Thomas R.

    2014-01-01

    Aims This study examined the impact of tobacco retail outlets on cessation outcomes over time among non-treatment-seeking smokers and assessed differences by neighborhood poverty and individual factors. Design Observational longitudinal cohort study using geospatial data. We used generalized estimating equations to examine cessation outcomes in relation to the proximity and density of tobacco retail outlets near the home. Setting Eight large Designated Media Areas across the U.S. Participants A total of 2,377 baseline smokers followed over 3 waves from 2008 to 2010. Measurements Outlet addresses were identified through North American Industry Classification System codes and proximity and density measures were constructed for each participant at each wave. Outcomes included past 30-day abstinence and pro-cessation attitudes. Findings Smokers in high poverty census tracts living between 500 meters and 1.9 kilometers from an outlet were over 2 times more likely to be abstinent than those living fewer than 500 meters from an outlet (p<.05). Density within 500 meters of home was associated with reduced abstinence (OR: 0.94; CI: 0.90, 0.98) and lower pro-cessation attitudes (Coef: −0.07, CI: −0.10, −0.03) only in high poverty areas. In low poverty areas, density within 500 meters was associated with greater pro-cessation attitudes (OR: 0.06; CI: 0.01, 0.12). Gender, education and heaviness of smoking did not moderate the impact of outlet proximity and density on cessation outcomes. Conclusions In the US, density of tobacco outlets within 500 meters of the home residence appears to be negatively associated with smoking abstinence and pro-cessation attitudes only in poor areas. PMID:25171184

  16. A sensitivity study of fast outlet glaciers to short timescale cyclical perturbations

    NASA Astrophysics Data System (ADS)

    Aykutlug, E.; Dupont, T. K.

    2015-01-01

    The dynamic response of outlet glaciers on short (annual to decadal) timescales is affected by various external forcings, such as basal or oceanic conditions. Understanding the sensitivity of the dynamic response to such forcings can help assess more accurate ice volume projections. In this work, we investigate the spatiotemporal sensitivity of outlet glaciers to fast cyclical forcings using a one-dimensional depth and width-averaged heuristic model. Our results indicate that even on such short timescales, nonlinearities in ice dynamics may lead to an asymmetric response, despite the forcing functions being symmetric around each reference value. Results also show that such short-timescale effects become more pronounced as glaciers become closer to flotation. While being qualitatively similar for both downsloping and upsloping bed geometries, the results indicate higher sensitivity for upsloping ("West Antarctica-like") beds. The range in asymmetric response for different configurations motivate parameterizing or including short-timescale effects in models while investigating the dynamic behavior of outlet glaciers.

  17. Organic contaminants in onsite wastewater treatment systems

    USGS Publications Warehouse

    Conn, K.E.; Siegrist, R.L.; Barber, L.B.; Brown, G.K.

    2007-01-01

    Wastewater from thirty onsite wastewater treatment systems was sampled during a reconnaissance field study to quantify bulk parameters and the occurrence of organic wastewater contaminants including endocrine disrupting compounds in treatment systems representing a variety of wastewater sources and treatment processes and their receiving environments. Bulk parameters ranged in concentrations representative of the wide variety of wastewater sources (residential vs. non-residential). Organic contaminants such as sterols, surfactant metabolites, antimicrobial agents, stimulants, metal-chelating agents, and other consumer product chemicals, measured by gas chromatography/mass spectrometry were detected frequently in onsite system wastewater. Wastewater composition was unique between source type likely due to differences in source water and chemical usage. Removal efficiencies varied by engineered treatment type and physicochemical properties of the contaminant, resulting in discharge to the soil treatment unit at ecotoxicologically-relevant concentrations. Organic wastewater contaminants were detected less frequently and at lower concentrations in onsite system receiving environments. Understanding the occurrence and fate of organic wastewater contaminants in onsite wastewater treatment systems will aid in minimizing risk to ecological and human health.

  18. Fischer-Tropsch Wastewater Utilization

    DOEpatents

    Shah, Lalit S.

    2003-03-18

    The present invention is generally directed to handling the wastewater, or condensate, from a hydrocarbon synthesis reactor. More particularly, the present invention provides a process wherein the wastewater of a hydrocarbon synthesis reactor, such as a Fischer-Tropsch reactor, is sent to a gasifier and subsequently reacted with steam and oxygen at high temperatures and pressures so as to produce synthesis gas. The wastewater may also be recycled back to a slurry preparation stage, where solid combustible organic materials are pulverized and mixed with process water and the wastewater to form a slurry, after which the slurry fed to a gasifier where it is reacted with steam and oxygen at high temperatures and pressures so as to produce synthesis gas.

  19. Mir-29 repression in bladder outlet obstruction contributes to matrix remodeling and altered stiffness.

    PubMed

    Ekman, Mari; Bhattachariya, Anirban; Dahan, Diana; Uvelius, Bengt; Albinsson, Sebastian; Swärd, Karl

    2013-01-01

    Recent work has uncovered a role of the microRNA (miRNA) miR-29 in remodeling of the extracellular matrix. Partial bladder outlet obstruction is a prevalent condition in older men with prostate enlargement that leads to matrix synthesis in the lower urinary tract and increases bladder stiffness. Here we tested the hypothesis that miR-29 is repressed in the bladder in outlet obstruction and that this has an impact on protein synthesis and matrix remodeling leading to increased bladder stiffness. c-Myc, NF-κB and SMAD3, all of which repress miR-29, were activated in the rat detrusor following partial bladder outlet obstruction but at different times. c-Myc and NF-κB activation occurred early after obstruction, and SMAD3 phosphorylation increased later, with a significant elevation at 6 weeks. c-Myc, NF-κB and SMAD3 activation, respectively, correlated with repression of miR-29b and miR-29c at 10 days of obstruction and with repression of miR-29c at 6 weeks. An mRNA microarray analysis showed that the reduction of miR-29 following outlet obstruction was associated with increased levels of miR-29 target mRNAs, including mRNAs for tropoelastin, the matricellular protein Sparc and collagen IV. Outlet obstruction increased protein levels of eight out of eight examined miR-29 targets, including tropoelastin and Sparc. Transfection of human bladder smooth muscle cells with antimiR-29c and miR-29c mimic caused reciprocal changes in target protein levels in vitro. Tamoxifen inducible and smooth muscle-specific deletion of Dicer in mice reduced miR-29 expression and increased tropoelastin and the thickness of the basal lamina surrounding smooth muscle cells in the bladder. It also increased detrusor stiffness independent of outlet obstruction. Taken together, our study supports a model where the combined repressive influences of c-Myc, NF-κB and SMAD3 reduce miR-29 in bladder outlet obstruction, and where the resulting drop in miR-29 contributes to matrix remodeling and

  20. Acrylonitrile removal from synthetic wastewater and actual industrial wastewater with high strength nitrogen using a pure bacteria culture.

    PubMed

    Wang, C C; Lee, C M; Cheng, P W

    2001-01-01

    A gram-negative rod-shaped bacteria (strain AAS6), capable of utilizing acrylonitrile as the sole source of both carbon and nitrogen, was utilized to investigate the removal of acrylonitrile in ABS resin manufacturing wastewater. Both synthetic wastewater, containing a high concentration of acrylonitrile, and actual wastewater obtained from an ABS manufacturing factory were used. The result indicated that strain AAS6 was capable of completely removing acrylonitrile from synthetic wastewater containing less than 889 mg/l acrylonitrile and from actual industrial wastewater containing less than 400 mg/l acrylonitrile. Whether in synthetic wastewater or actual industrial wastewater, strain AAS6 showed approximately the same ability for acrylonitrile removal and used acrylic acid, a metabolic by-product of acrylonitrile, as the carbon source and ammonium as the nitrogen source. The bacteria could not directly metabolize other chemicals found in the actual industrial wastewater. However, its metabolic activities were not inhibited by the presence of compounds such as butadiene, styrene or acrylonitrile-styrene polymer. Thus, this strain is expected to play an important role in aeration tanks for treating ABS resin manufacturing wastewater.

  1. Some Chinese folk prescriptions for wind-cold type common cold.

    PubMed

    Hai-Long, Zhai; Shimin, Chen; Yalan, Lu

    2015-07-01

    Although self-limiting, the common cold (gǎn mào) is highly prevalent. There are no effective antivirals to cure the common cold and few effective measures to prevent it, However, for thousands years, Chinese people have treated the common cold with natural herbs, According to the traditional Chinese medicine (TCM) theory ( zhōng yī lǐ lùn), the common cold is considered as an exterior syndrome, which can be further divided into the wind-cold type ( fēng hán xíng), the wind-heat type ( fēng rè xíng), and the summer heat dampness type ( shǔ rè xíng). Since the most common type of common cold caught in winter and spring is the wind-cold type, the article introduced some Chinese folk prescriptions for the wind-cold type common cold with normal and weak physique, respectively. For thousands of years, Chinese folk prescriptions for the common cold, as complementary and alternative medicine (CAM; bǔ chōng yǔ tì dài yī xué), have been proven to be effective, convenient, cheap, and most importantly, safe. The Chinese folk prescriptions ( zhōng guó mín jiān chǔ fāng) for the wind-cold type common cold are quite suitable for general practitioners or patients with the wind-cold type common cold, to treat the disease. Of course, their pharmacological features and mechanisms of action need to be further studied.

  2. Associations between county and municipality zoning ordinances and access to fruit and vegetable outlets in rural North Carolina, 2012.

    PubMed

    Mayo, Mariel Leah; Pitts, Stephanie B Jilcott; Chriqui, Jamie F

    2013-12-05

    Zoning ordinances and land-use plans may influence the community food environment by determining placement and access to food outlets, which subsequently support or hinder residents' attempts to eat healthfully. The objective of this study was to examine associations between healthful food zoning scores as derived from information on local zoning ordinances, county demographics, and residents' access to fruit and vegetable outlets in rural northeastern North Carolina. From November 2012 through March 2013, county and municipality zoning ordinances were identified and double-coded by using the Bridging the Gap food code/policy audit form. A healthful food zoning score was derived by assigning points for the allowed use of fruit and vegetable outlets. Pearson coefficients were calculated to examine correlations between the healthful food zoning score, county demographics, and the number of fruit and vegetable outlets. In March and April 2013, qualitative interviews were conducted among county and municipal staff members knowledgeable about local zoning and planning to ascertain implementation and enforcement of zoning to support fruit and vegetable outlets. We found a strong positive correlation between healthful food zoning scores and the number of fruit and vegetable outlets in 13 northeastern North Carolina counties (r = 0.66, P = .01). Major themes in implementation and enforcement of zoning to support fruit and vegetable outlets included strict enforcement versus lack of enforcement of zoning regulations. Increasing the range of permitted uses in zoning districts to include fruit and vegetable outlets may increase access to healthful fruit and vegetable outlets in rural communities.

  3. Associations Between County and Municipality Zoning Ordinances and Access to Fruit And Vegetable Outlets in Rural North Carolina, 2012

    PubMed Central

    Mayo, Mariel Leah; Chriqui, Jamie F.

    2013-01-01

    Introduction Zoning ordinances and land-use plans may influence the community food environment by determining placement and access to food outlets, which subsequently support or hinder residents’ attempts to eat healthfully. The objective of this study was to examine associations between healthful food zoning scores as derived from information on local zoning ordinances, county demographics, and residents’ access to fruit and vegetable outlets in rural northeastern North Carolina. Methods From November 2012 through March 2013, county and municipality zoning ordinances were identified and double-coded by using the Bridging the Gap food code/policy audit form. A healthful food zoning score was derived by assigning points for the allowed use of fruit and vegetable outlets. Pearson coefficients were calculated to examine correlations between the healthful food zoning score, county demographics, and the number of fruit and vegetable outlets. In March and April 2013, qualitative interviews were conducted among county and municipal staff members knowledgeable about local zoning and planning to ascertain implementation and enforcement of zoning to support fruit and vegetable outlets. Results We found a strong positive correlation between healthful food zoning scores and the number of fruit and vegetable outlets in 13 northeastern North Carolina counties (r = 0.66, P = .01). Major themes in implementation and enforcement of zoning to support fruit and vegetable outlets included strict enforcement versus lack of enforcement of zoning regulations. Conclusion Increasing the range of permitted uses in zoning districts to include fruit and vegetable outlets may increase access to healthful fruit and vegetable outlets in rural communities. PMID:24309091

  4. Does neighborhood fast-food outlet exposure amplify inequalities in diet and obesity? A cross-sectional study12

    PubMed Central

    Forouhi, Nita G; Griffin, Simon J; Brage, Søren; Wareham, Nicholas J

    2016-01-01

    Background: Greater exposures to fast-food outlets and lower levels of education are independently associated with less healthy diets and obesity. Little is known about the interplay between these environmental and individual factors. Objective: The purpose of this study was to test whether observed differences in fast-food consumption and obesity by fast-food outlet exposure are moderated by educational attainment. Design: In a population-based cohort of 5958 adults aged 29–62 y in Cambridgeshire, United Kingdom, we used educational attainment–stratified regression models to estimate the food-frequency questionnaire–derived consumption of energy-dense “fast foods” (g/d) typically sold in fast-food restaurants and measured body mass index (BMI; in kg/m2) across geographic information system–derived home and work fast-food exposure quartiles. We used logistic regression to estimate the odds of obesity (BMI ≥30) and calculated relative excess risk due to interaction (RERI) on an additive scale. Participant data were collected during 2005–2013 and analyzed in 2015. Results: Greater fast-food consumption, BMI, and odds of obesity were associated with greater fast-food outlet exposure and a lower educational level. Fast-food consumption and BMI were significantly different across education groups at all levels of fast-food outlet exposure (P < 0.05). High fast-food outlet exposure amplified differences in fast-food consumption across levels of education. The relation between fast-food outlet exposure and obesity was only significant among those who were least educated (OR: 2.05; 95% CI: 1.08, 3.87; RERI = 0.88), which suggested a positive additive interaction between education and fast-food outlet exposure. Conclusion: These findings suggest that efforts to improve diets and health through neighborhood-level fast-food outlet regulation might be effective across socioeconomic groups and may serve to reduce observed socioeconomic inequalities in diet and

  5. Soil Variable Permeability and Water Phase Change Dynamics in a Wastewater Spray Irrigation Agricultural System Located in a Seasonably Cold Climate

    NASA Astrophysics Data System (ADS)

    Darnault, C. J. G.; Daniel, T. J.; Billy, G.; Hopkins, I.; Guo, L.; Jin, Z.; Gall, H. E.; Lin, H.

    2017-12-01

    The permeability of the upper meter of soils in frozen conditions, commonly referred to as the active layer, can vary exponentially given the time of year. Variable moisture contents along with temperature, radiation, and slope angle of the soil surface can result in variable depths of frozen soils, which can cause the formation of low permeability ice lenses well into the spring thaw period. The wastewater irrigation site known as the "Living Filter" located in State College, PA has been in continuous operation since 1962. On average 5500 m3/day of wastewater is applied to the site annually, even in the winter months when average temperatures can dip as low as -7 °C during the month of January. The Living Filter is not permitted to discharge to surface water and is intended to recharge the Spring Creek basin that directly underlies the site, therefore runoff from the site is not permitted. We hypothesize that water infiltrates the upper meter of the subsurface during the winter in several different ways such as preferential pathways in the ice layer created by plant stems and weak patches of ice thawed by the warm wastewater. 2D conceptual models of the phase change between ice and water in the soil were created in order to predict soil permeability and its change in temperature. The 2D conceptual models can be correlated between observed soil moisture content and soil temperature data in order to validate the model given spray irrigation and weather patterns. By determining the permeability of the frozen soils, irrigation practices can be adjusted for the winter months so as to reduce the risk of any accidental wastewater runoff. The impact of this study will result in a better understanding of the multiphase dynamics of the active layer and their implication on soil hydrology at the Living Filter and other seasonally frozen sites.

  6. Regional abundance of on-premise outlets and drinking patterns among Swiss young men: district level analyses and geographic adjustments.

    PubMed

    Astudillo, Mariana; Kuendig, Hervé; Centeno-Gil, Adriana; Wicki, Matthias; Gmel, Gerhard

    2014-09-01

    This study investigated the associations of alcohol outlet density with specific alcohol outcomes (consumption and consequences) among young men in Switzerland and assessed the possible geographically related variations. Alcohol consumption and drinking consequences were measured in a 2010-2011 study assessing substance use risk factors (Cohort Study on Substance Use Risk Factors) among 5519 young Swiss men. Outlet density was based on the number of on- and off-premise outlets in the district of residence. Linear regression models were run separately for drinking level, heavy episodic drinking (HED) and drinking consequences. Geographically weighted regression models were estimated when variations were recorded at the district level. No consistent association was found between outlet density and drinking consequences. A positive association between drinking level and HED with on-premise outlet density was found. Geographically weighted regressions were run for drinking level and HED. The predicted values for HED were higher in the southwest part of Switzerland (French-speaking part). Among Swiss young men, the density of outlets and, in particular, the abundance of bars, clubs and other on-premise outlets was associated with drinking level and HED, even when drinking consequences were not significantly affected. These findings support the idea that outlet density needs to be considered when developing and implementing regional-based prevention initiatives. © 2014 Australasian Professional Society on Alcohol and other Drugs.

  7. Henoch Schönlein purpura presenting as duodenal ulcer and gastric outlet obstruction.

    PubMed

    Rathore, Mukesh; Shrivastava, Rimjhim; Goyal, Ravinder; Radotra, B D; Thapa, B R

    2014-02-01

    Henoch-Schönlein purpura (HSP) is an acute small vessel leucocytoclastic vasculitis. It is the commonest vasculitis in children, with an incidence of about 10 cases per 100, 000 a year. Gastrointestinal manifestations are commonly encountered, however hematemesis and gastric outlet obstruction are rarely reported. The authors present the case of a 5-y-old boy having hematemesis, gastric outlet obstruction and multiple duodenal ulcers. He improved with steroids and conservative management.

  8. A cross-sectional analysis of the relationship between tobacco and alcohol outlet density and neighbourhood deprivation.

    PubMed

    Shortt, Niamh K; Tisch, Catherine; Pearce, Jamie; Mitchell, Richard; Richardson, Elizabeth A; Hill, Sarah; Collin, Jeff

    2015-10-05

    There is a strong socio-economic gradient in both tobacco-and alcohol-related harm. One possible factor contributing to this social gradient may be greater availability of tobacco and alcohol in more socially-deprived areas. A higher density of tobacco and alcohol outlets is not only likely to increase supply but also to raise awareness of tobacco/alcohol brands, create a competitive local market that reduces product costs, and influence local social norms relating to tobacco and alcohol consumption. This paper examines the association between the density of alcohol and tobacco outlets and neighbourhood-level income deprivation. Using a national tobacco retailer register and alcohol licensing data this paper calculates the density of alcohol and tobacco retail outlets per 10,000 population for small neighbourhoods across the whole of Scotland. Average outlet density was calculated for neighbourhoods grouped by their level of income deprivation. Associations between outlet density and deprivation were analysed using one way analysis of variance. There was a positive linear relationship between neighbourhood deprivation and outlets for both tobacco (p <0.001) and off-sales alcohol (p <0.001); the most deprived quintile of neighbourhoods had the highest densities of both. In contrast, the least deprived quintile had the lowest density of tobacco and both off-sales and on-sales alcohol outlets. The social gradient evident in alcohol and tobacco supply may be a contributing factor to the social gradient in alcohol- and tobacco-related disease. Policymakers should consider such gradients when creating tobacco and alcohol control policies. The potential contribution to public health, and health inequalities, of reducing the physical availability of both alcohol and tobacco products should be examined in developing broader supply-side interventions.

  9. The impact of the tobacco retail outlet environment on adult cessation and differences by neighborhood poverty.

    PubMed

    Cantrell, Jennifer; Anesetti-Rothermel, Andrew; Pearson, Jennifer L; Xiao, Haijun; Vallone, Donna; Kirchner, Thomas R

    2015-01-01

    This study examined the impact of tobacco retail outlets on cessation outcomes over time among non-treatment-seeking smokers and assessed differences by neighborhood poverty and individual factors. Observational longitudinal cohort study using geospatial data. We used generalized estimating equations to examine cessation outcomes in relation to the proximity and density of tobacco retail outlets near the home. Eight large Designated Media Areas across the United States. A total of 2377 baseline smokers followed over three waves from 2008 to 2010. Outlet addresses were identified through North American Industry Classification System codes and proximity and density measures were constructed for each participant at each wave. Outcomes included past 30-day abstinence and pro-cessation attitudes. Smokers in high poverty census tracts living between 500 m and 1.9 km from an outlet were over two times more likely to be abstinent than those living fewer than 500 m from an outlet (P < 0.05). Density within 500 m of home was associated with reduced abstinence [odds ratio (OR) = 0.94; confidence interval (CI) = 0.90, 0.98) and lower pro-cessation attitudes (Coeff = -0.07, CI = -0.10, -0.03) only in high poverty areas. In low poverty areas, density within 500 m was associated with greater pro-cessation attitudes (OR = 0.06; CI = 0.01, 0.12). Gender, education and heaviness of smoking did not moderate the impact of outlet proximity and density on cessation outcomes. In the United States, density of tobacco outlets within 500 m of the home residence appears to be negatively associated with smoking abstinence and pro-cessation attitudes only in poor areas. © 2014 Society for the Study of Addiction.

  10. Water Quality Outlet Works Prototype Tests, Warm Springs Dam Dry Creek, Russian River Basin Sonoma County, California

    DTIC Science & Technology

    1989-03-01

    34.4* TECHNICAL REPORT HL-89-4 WATER QUALITY OUTLET WORKS PROTOTYPE TESTS, WARM SPRINGS DAM DRY CREEK, RUSSIAN RIVER BASIN AD-A207 058 SONOMA COUNTY , CALIFORNIA...Clawflcation) [7 Water Quality Outlet Works Prototype Tests, Warm Springs Dam, Dry Creek, Russian River Basin, Sonoma County , California 12. PERSONAL...Cointogobvil Be,,pesso Figur 1. iciniyama Pealm WATER QUALITY OUTLET WORKS PROTOTYPE TESTS WARM SPRINGS DAM, DRY CREEK, RUSSIAN RIVER BASIN SONOMA COUNTY , CALIFORNIA

  11. OCCURRENCE OF PATHOGENS IN MUNICIPAL WASTEWATER AND THEIR SURVIVAL DURING WASTEWATER TREATMENT

    EPA Science Inventory

    Pathogens can enter municipal wastewaters from several sources including homes, hospitals and slaughter houses. They are identified, typical levels found in sludges are given along with infectious doses, and their survival on crops and in the soil presented. As wastewater is clea...

  12. A California Winery Wastewater Survey: Assessing the Salinity Challenge for Wastewater Reuse

    USDA-ARS?s Scientific Manuscript database

    The increasing scarcity of water and tighter regulations for discharge make onsite wastewater reuse an attractive prospect for the California wine industry. This study reports winery wastewater (WW) data from eighteen Northern California (Northern CA) wineries. The current study provides a baseline ...

  13. 7. WEST DAM STRUCTURE, LOOKING NORTHWEST. QUARRIES AT BOTTOM; OUTLET ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    7. WEST DAM STRUCTURE, LOOKING NORTHWEST. QUARRIES AT BOTTOM; OUTLET STRUCTURE UNDER CONSTRUCTION CUTTING INTO HILL AT TOP OF PICTURE. - Eastside Reservoir, Diamond & Domenigoni Valleys, southwest of Hemet, Hemet, Riverside County, CA

  14. Special type culvert headwall, Culvert No. 124 Outlet, oblique view, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Special type culvert headwall, Culvert No. 124 Outlet, oblique view, view to southwest - Route No. 1-Overton-Lake Mead Road, Culverts and Headwalls, 6 miles south of Overton, Overton, Clark County, NV

  15. Special type culvert headwall, Culvert No. 109 Outlet, oblique view, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Special type culvert headwall, Culvert No. 109 Outlet, oblique view, view to southeast - Route No. 1-Overton-Lake Mead Road, Culverts and Headwalls, 6 miles south of Overton, Overton, Clark County, NV

  16. 6. VIEW SHOWING INCLINED OUTLET GATE WHEEL, STEM AND STEM ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    6. VIEW SHOWING INCLINED OUTLET GATE WHEEL, STEM AND STEM GUIDE (18' HARDESTY GATE), LOOKING SOUTHEAST - High Mountain Dams in Bonneville Unit, Long Lake Dam, Wasatch National Forest, Kamas, Summit County, UT

  17. 5. VIEW OF UPRIGHT OUTLET GATE WHEEL, STEM AND STEM ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. VIEW OF UPRIGHT OUTLET GATE WHEEL, STEM AND STEM GUIDE (HARDESTY CAST IRON RECTANGULAR SLIDE GATE), LOOKING SOUTHWEST - High Mountain Dams in Bonneville Unit, Lost Lake Dam, Kamas, Summit County, UT

  18. Electrochemical disinfection of toilet wastewater using wastewater electrolysis cell

    PubMed Central

    Huang, Xiao; Qu, Yan; Cid, Clément A.; Finke, Cody; Hoffmann, Michael R.; Lim, Keahying; Jiang, Sunny C.

    2016-01-01

    The paucity of proper sanitation facilities has contributed to the spread of waterborne diseases in many developing countries. The primary goal of this study was to demonstrate the feasibility of using a wastewater electrolysis cell (WEC) for toilet wastewater disinfection. The treated wastewater was designed to reuse for toilet flushing and agricultural irrigation. Laboratory-scale electrochemical (EC) disinfection experiments were performed to investigate the disinfection efficiency of the WEC with four seeded microorganisms (Escherichia coli, Enterococcus, recombinant adenovirus serotype 5, and bacteriophage MS2). In addition, the formation of organic disinfection byproducts (DBPs) trihalomethanes (THMs) and haloacetic acids (HAA5) at the end of the EC treatment was also investigated. The results showed that at an applied cell voltage of +4 V, the WEC achieved 5-log10 reductions of all four seeded microorganisms in real toilet wastewater within 60 min. In contrast, chemical chlorination (CC) disinfection using hypochlorite [NaClO] was only effective for the inactivation of bacteria. Due to the rapid formation of chloramines, less than 0.5-log10 reduction of MS2 was observed in toilet wastewater even at the highest [NaClO] dosage (36 mg/L, as Cl2) over a 1 h reaction. Experiments using laboratory model waters showed that free reactive chlorine generated in situ during EC disinfection process was the main disinfectant responsible for the inactivation of microorganisms. However, the production of hydroxyl radicals [•OH], and other reactive oxygen species by the active bismuth-doped TiO2 anode were negligible under the same electrolytic conditions. The formation of THMs and HAA5 were found to increase with higher applied cell voltage. Based on the energy consumption estimates, the WEC system can be operated using solar energy stored in a DC battery as the sole power source. PMID:26854604

  19. The association between the density of retail tobacco outlets, individual smoking status, neighbourhood socioeconomic status and school locations in New South Wales, Australia.

    PubMed

    Marashi-Pour, Sadaf; Cretikos, Michelle; Lyons, Claudine; Rose, Nick; Jalaludin, Bin; Smith, Joanne

    2015-01-01

    We explored the association between the density of tobacco outlets and neighbourhood socioeconomic status, and between neighbourhood tobacco outlet density and individual smoking status. We also investigated the density of tobacco outlets around primary and secondary schools in New South Wales (NSW). We calculated the mean density of retail tobacco outlets registered in NSW between 2009 and 2011, using kernel density estimation with an adaptive bandwidth. We used generalised ordered logistic regression model to explore the association between socioeconomic status and density of tobacco outlets. The association between neighbourhood tobacco outlet density and individuals' current smoking status was investigated using random-intercept generalised linear mixed models. We also calculated the median tobacco outlet density around NSW schools. More disadvantaged Census Collection Districts (CDs) were significantly more likely to have higher tobacco outlet densities. After adjusting for neighbourhood socioeconomic status and participants' age, sex, country of birth and Aboriginal status, neighbourhood mean tobacco outlet density was significantly and positively associated with individuals' smoking status. The median of tobacco outlet density around schools was significantly higher than the state median. Policymakers could consider exploring a range of strategies that target tobacco outlets in proximity to schools, in more disadvantaged neighbourhoods and in areas of existing high tobacco outlet density. Crown Copyright © 2014. Published by Elsevier Ltd. All rights reserved.

  20. Antral hyperplastic polyp: A rare cause of gastric outlet obstruction

    PubMed Central

    Aydin, Ibrahim; Ozer, Ender; Rakici, Halil; Sehitoglu, Ibrahim; Yucel, Ahmet Fikret; Pergel, Ahmet; Sahin, Dursun Ali

    2014-01-01

    INTRODUCTION Gastric polyps are usually found incidentally during upper gastrointestinal endoscopic examinations. These polyps are generally benign, with hyperplasia being the most common. While gastric polyps are often asymptomatic, they can cause gastric outlet obstruction. PRESENTATION OF CASE A 64 years-old female patient presented to our polyclinic with a history of approximately 2 months of weakness, occasional early nausea, vomiting after meals and epigastric pain. A polypoid lesion of approximately 25 mm in diameter was detected in the antral area of the stomach, which prolapsed through the pylorus into the duodenal bulbus, and subsequently caused gastric outlet obstruction, as revealed by upper gastrointestinal endoscopy of the patient. The polyp was retrieved from the pyloric canal into the stomach with the aid of a tripod, and snare polypectomy was performed. DISCUSSION Currently, widespread use of endoscopy has led to an increase in the frequency of detecting hyperplastic polyps. While most gastric polyps are asymptomatic, they can cause iron deficiency anemia, acute pancreatitis and more commonly, gastric outlet obstruction because of their antral location. Although there are no precise principles in the treatment of asymptomatic polyps, polyps >5 mm should be removed due to the possibility of malignant transformation. CONCLUSION According to the medical evidence, polypectomy is required for gastric hyperplastic polyps because of the risks of complication and malignancy. These cases can be successfully treated endoscopically. PMID:24747755

  1. Benefits and limitations of animal models in partial bladder outlet obstruction for translational research.

    PubMed

    Kitta, Takeya; Kanno, Yukiko; Chiba, Hiroki; Higuchi, Madoka; Ouchi, Mifuka; Togo, Mio; Moriya, Kimihiko; Shinohara, Nobuo

    2018-01-01

    The functions of the lower urinary tract have been investigated for more than a century. Lower urinary tract symptoms, such as incomplete bladder emptying, weak urine stream, daytime urinary frequency, urgency, urge incontinence and nocturia after partial bladder outlet obstruction, is a frequent cause of benign prostatic hyperplasia in aging men. However, the pathophysiological mechanisms have not been fully elucidated. The use of animal models is absolutely imperative for understanding the pathophysiological processes involved in bladder dysfunction. Surgical induction has been used to study lower urinary tract functions of numerous animal species, such as pig, dog, rabbit, guinea pig, rat and mouse, of both sexes. Several morphological and functional modifications under partial bladder outlet obstruction have not only been observed in the bladder, but also in the central nervous system. Understanding the changes of the lower urinary tract functions induced by partial bladder outlet obstruction would also contribute to appropriate drug development for treating these pathophysiological conditions. In the present review, we discuss techniques for creating partial bladder outlet obstruction, the characteristics of several species, as well as issues of each model, and their translational value. © 2017 The Japanese Urological Association.

  2. The concept of double inlet-double outlet right ventricle: a distinct congenital heart disease.

    PubMed

    Spadotto, Veronica; Frescura, Carla; Ho, Siew Yen; Thiene, Gaetano

    The aim of this study was to estimate the incidence and to analyze the anatomy of double inlet-double outlet right ventricle complex and its associated cardiac anomalies in our autopsy series. Among the 1640 hearts with congenital heart disease of our Anatomical Collection, we reviewed the specimens with double inlet-double outlet right ventricle, according to the sequential-segmental analysis, identifying associated cardiac anomalies and examining lung histology to assess the presence of pulmonary vascular disease. We identified 14 hearts with double inlet-double outlet right ventricle (0.85%). Right atrial isomerism was observed in 10 hearts, situs solitus in 3 and left atrial isomerism in one. Regarding the mode of atrioventricular connection, all hearts but one had a common atrioventricular valve. Systemic or pulmonary venous abnormalities were noted in all patients with atrial isomerism. In nine patients a valvular or subvalvular pulmonary stenosis was present. Among the functionally "univentricular hearts", double inlet- double outlet right ventricle represents a peculiar entity, mostly in association with right atrial isomerism. Multiple cardiac anomalies are associated and may complicate surgical repair. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. The relationship between the density of alcohol outlets and parental supply of alcohol to adolescents.

    PubMed

    Rowland, B; Toumbourou, J W; Satyen, L; Livingston, M; Williams, J

    2014-12-01

    This study investigated whether the number of alcohol outlets per 10,000 population in a given area (density) influenced parental supply of alcohol to adolescents; differences in Australian born and acculturating parents were also examined. A state-representative student survey in Victoria identified that the majority of adolescents (55%) reported that they had used alcohol in the past 12months; 34 % of those who had consumed alcohol reported that it had been supplied by their parents. Multilevel modelling identified that there were no overall effects of density, however there were different effects based on parent country of birth and type of license. Specifically, each unit increase in the density of takeaway liquor stores increased the likelihood by 2.03 that children with both Australian-born parents would be supplied alcohol. Adolescents with both migrant parents on the other hand, had a 1.36 increased risk of being supplied alcohol as the density of outlets requiring at-venue consumption increased. The findings of this study suggest that in Australia, alcohol outlet density is associated with parental supply of alcohol to children, with this effect moderated by the cultural background of the parent and type of outlet density. Future research should investigate the association between the density of alcohol outlets and public approval of parents supplying alcohol to adolescents. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. 7 CFR 3201.98 - Wastewater systems coatings.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 15 2014-01-01 2014-01-01 false Wastewater systems coatings. 3201.98 Section 3201.98... Designated Items § 3201.98 Wastewater systems coatings. (a) Definition. Coatings that protect wastewater... procurement preference for qualifying biobased wastewater systems coatings. By that date, Federal agencies...

  5. 7 CFR 3201.98 - Wastewater systems coatings.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 15 2013-01-01 2013-01-01 false Wastewater systems coatings. 3201.98 Section 3201.98... Designated Items § 3201.98 Wastewater systems coatings. (a) Definition. Coatings that protect wastewater... procurement preference for qualifying biobased wastewater systems coatings. By that date, Federal agencies...

  6. 40 CFR 420.97 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... cold rolling wastewaters. 2 Within the range of 6.0 to 9.0. (2) Bar, billet and bloom. Subpart I... treated with cold rolling wastewaters. 2 Within the range of 6.0 to 9.0. (3) Strip, sheet and plate... are treated with cold rolling wastewaters. 2 Within the range of 6.0 to 9.0. (4) Pipe, tube and other...

  7. Assessment of the disinfection capacity and eco-toxicological impact of atmospheric cold plasma for treatment of food industry effluents.

    PubMed

    Patange, Apurva; Boehm, Daniela; Giltrap, Michelle; Lu, Peng; Cullen, P J; Bourke, Paula

    2018-08-01

    Generation of wastewater is one of the main environmental sustainability issues across food sector industries. The constituents of food process effluents are often complex and require high energy and processing for regulatory compliance. Wastewater streams are the subject of microbiological and chemical criteria, and can have a significant eco-toxicological impact on the aquatic life. Thus, innovative treatment approaches are required to mitigate environmental impact in an energy efficient manner. Here, dielectric barrier discharge atmospheric cold plasma (ACP) was evaluated for control of key microbial indicators encountered in food industry effluent. This study also investigated the eco-toxicological impact of cold plasma treatment of the effluents using a range of aquatic bioassays. Continuous ACP treatment was applied to synthetic dairy and meat effluents. Microbial inactivation showed treatment time dependence with significant reduction in microbial populations within 120 s, and to undetectable levels after 300 s. Post treatment retention time emerged as critical control parameter which promoted ACP bacterial inactivation efficiency. Moreover, ACP treatment for 20 min achieved significant reduction (≥2 Log 10 ) in Bacillus megaterium endospores in wastewater effluent. Acute aquatic toxicity was assessed using two fish cell lines (PLHC-1 and RTG-2) and a crustacean model (Daphnia magna). Untreated effluents were toxic to the aquatic models, however, plasma treatment limited the toxic effects. Differing sensitivities were observed to ACP treated effluents across the different test bio-assays in the following order: PLHC-1 > RTG-2 ≥ D. magna; with greater sensitivity retained to plasma treated meat effluent than dairy effluent. The toxic effects were dependent on concentration and treatment time of the ACP treated effluent; with 30% cytotoxicity in D. magna and fish cells observed after 24 h of exposure to ACP treated effluent for

  8. Towards the Complete Characterization of Marine-Terminating Glacier Outlet Systems

    NASA Astrophysics Data System (ADS)

    Mayer, L. A.; Jakobsson, M.; Mix, A. C.; Jerram, K.; Hogan, K.; Heffron, E.; Muenchow, A.

    2016-12-01

    The Petermann Glacier Experiment was aimed at understanding past variations in Petermann Glacier and their relationship to changes in climatic and oceanographic conditions. A critical component of the experiment was a comprehensive program conducted on the icebreaker Oden to map submarine glacial landforms, offering insight into past ice dynamics and establishing the overall geomorphological context of the region. Concurrent water-column mapping provided remarkable insight into modern glacial, oceanographic, and biological processes suggesting that a carefully designed experiment could provide a near-complete characterization of marine-terminating glacier outlet systems. Water-column mapping revealed seeps emanating from several seafloor regions. These features appeared along common depth zones and may represent fresh water emanating from a submerged aquifer; initial pore water analyses of cores also imply a fresh water flux into the fjord system. Water-column data also show a spatially consistent but variable distribution of a strong mid-water scattering layer, a biological response possibly tracing the inflow of Atlantic water into the fjord and enhanced by input from local outlet glaciers. The continuous nature of these acoustic records over 30 days offers a complete 4-D picture of the distribution of the scattering layer (and perhaps internal circulation patterns and water-mass interactions) with a spatial and temporal distribution far beyond that achievable by traditional oceanographic stations. Additional, higher-resolution water-column imaging around local outlet glaciers presents a clear picture of subglacial sediment-laden meltwater plumes. Thus in addition to the paleoceanographic information they provided, the acoustic systems deployed captured a 4D-view of many of the modern geological, oceanographic and ecological processes within and adjacent to the Petermann Glacier marine system. With the addition of seafloor and water-column sampling, long

  9. 7. VIEW OF INCLINED OUTLET GATE WHEEL, STEM AND STEM ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    7. VIEW OF INCLINED OUTLET GATE WHEEL, STEM AND STEM GUIDE (15' HARDESTY MODEL 115 GATE), LOOKING NORTHWEST - High Mountain Dams in Bonneville Unit, Marjorie Lake Dam, Wasatch National Forest, Kamas, Summit County, UT

  10. 4. VIEW OF INCLINED OUTLET GATE, STEM, STEM GUIDE AND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    4. VIEW OF INCLINED OUTLET GATE, STEM, STEM GUIDE AND WHEEL (10' HARDESTY VERTICAL LIFT GATE), LOOKING NORTHWEST - High Mountain Dams in Bonneville Unit, Pot Lake Dam, Wasatch National Forest, Kamas, Summit County, UT

  11. 6. VIEW OF OUTLET GATE WHEEL AND STEM, LOOKING NORTHWEST ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    6. VIEW OF OUTLET GATE WHEEL AND STEM, LOOKING NORTHWEST - High Mountain Dams in Upalco Unit, Twin Pots Dam, Ashley National Forest, 10.1 miles North of Mountain Home, Mountain Home, Duchesne County, UT

  12. 3. AERIAL VIEW OF THREE BEARS LAKE, SHOWING OUTLET STREAM, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    3. AERIAL VIEW OF THREE BEARS LAKE, SHOWING OUTLET STREAM, BURLINGTON NORTHERN TRACKS, AND U.S. HIGHWAY 2, LOOKING NORTHEAST - Three Bears Lake & Dams, North of Marias Pass, East Glacier Park, Glacier County, MT

  13. Relationship between community-level alcohol outlet accessibility and individual-level herpes simplex virus type 2 infection among young women in South Africa.

    PubMed

    Rosenberg, Molly; Pettifor, Audrey; Lippman, Sheri A; Thirumurthy, Harsha; Emch, Michael; Miller, William C; Selin, Amanda; Gómez-Olivé, Francesc Xavier; Hughes, James P; Laeyendecker, Oliver; Tollman, Stephen; Kahn, Kathleen

    2015-05-01

    Exposure to alcohol outlets may influence sexual health outcomes at the individual and community levels. Visiting alcohol outlets facilitates alcohol consumption and exposes patrons to a risky environment and network of potential partners, whereas the presence of alcohol outlets in the community may shift social acceptance of riskier behavior. We hypothesize that living in communities with more alcohol outlets is associated with increased sexual risk. We performed a cross-sectional analysis in a sample of 2174 South African schoolgirls (ages 13-21 years) living across 24 villages in the rural Agincourt subdistrict, underpinned by long-term health and sociodemographic surveillance. To examine the association between number of alcohol outlets in village of residence and individual-level prevalent herpes simplex virus type 2 (HSV-2) infection, we used generalized estimating equations with logit links, adjusting for individual- and village-level covariates. The median number of alcohol outlets per village was 3 (range, 0-7). Herpes simplex virus type 2 prevalence increased from villages with no outlets (1.4% [95% confidence interval, 0.2-12.1]), to villages with 1 to 4 outlets (4.5% [3.7-5.5]), and to villages with more than 4 outlets (6.3% [5.6, 7.1]). An increase of 1 alcohol outlet per village was associated with an 11% increase in the odds of HSV-2 infection (adjusted odds ratio [95% confidence interval], 1.11 [0.98-1.25]). Living in villages with more alcohol outlets was associated with increased prevalence of HSV-2 infection in young women. Structural interventions and sexual health screenings targeting villages with extensive alcohol outlet environments could help prevent the spread of sexually transmitted infections.

  14. Biodegradability of tannin-containing wastewater from leather industry.

    PubMed

    He, Qiang; Yao, Kai; Sun, Danhong; Shi, Bi

    2007-08-01

    Tannins occur commonly in the wastewaters from forestry, plant medicine, paper and leather industries. The treatment of this kind of wastewaters, including settling and biodegradation, is usually difficult because tannins are highly soluble in water and would inhibit the growth of microorganisms in activated sludge. The objective of this study is to investigate biodegradability of tannin-containing wastewaters, so as to characterize the pollution properties of such wastewaters and provide a reference for their biological treatment in wastewater treatment plants. The research was typified by using the wastewater collected from vegetable tanning process in leather industry. A model was developed to describe the activated sludge process, and the biodegradation kinetics of vegetable tanning wastewater (VET wastewater) was studied. It was found that the biodegradability of tannin-containing wastewater varies heavily with the content of tannins in wastewater. The biodegradation of VET wastewater with tannin content around 4,900 mg/l occurred inefficiently due to the inhibition of tannins to the activated sludge process, and only 34.7% of biodegradation extent was reached in 14 days of incubation. The optimal biodegradability of VET wastewater was observed when its tannin content was diluted to 490 mg/l, where the COD and tannin removals reached 51.3% and 45.1% respectively in 6 days. Hence, it is suggested that a proper control of tannin content is necessary to achieve an effective biodegradation of tannin-containing wastewaters in wastewater treatment plants.

  15. Organic wastewater compounds in water and sediment in and near restored wetlands, Great Marsh, Indiana Dunes National Lakeshore, 2009–11

    USGS Publications Warehouse

    Egler, Amanda L.; Risch, Martin R.; Alvarez, David A.; Bradley, Paul M.

    2013-01-01

    ) were detected in more than half of the extracts from passive samplers, but they were not detected in any discrete water sample. The Yeast Estrogen Screen assay identified measurable estrogenicity in one passive sampler extract from the most downstream wetland site in both the April and November–December 2011 deployments and in passive sampler extracts from one residential and one upstream site in the November–December 2011 deployment only. Surface-water levels in the restored wetland cells were monitored continuously using submersible pressure transducers in hand-driven well points screened in the surface water. Surface-water levels in the wetland cells responded quickly to precipitation and substantially receded within 2 days following the largest rainfall events. Seasonal patterns in water levels generally showed higher and more variable surface-water levels in the wetland cells during spring and early summer. Water levels in the wetland cells fell below the elevation of the control structures and ceased to flow over the spillways during extended dry periods (primarily late summer and early fall). Daily loads of seven organic wastewater compounds, as indicators of septic system effluent, were estimated for samples collected at wetland outlet spillways when flow measurements could be made. Median daily loads of the indicator organic wastewater compounds increased in downstream order, and the largest median loads were measured at the most downstream site. Median daily loads were higher for samples collected in spring and summer than those collected in fall, as the higher seasonal water levels increased streamflow at the wetland outlet spillways. Wetland sediment samples were analyzed for 84 organic wastewater compounds, polycyclic aromatic hydrocarbons, and semivolatile organic compounds to investigate the fate of contaminants in Great Marsh. The top five detected compounds by total mass in wetland sediment samples were beta-sitosterol, beta

  16. Access to food retail outlets in County Durham, UK: a pragmatic cross-sectional study.

    PubMed

    Mills, Susanna; Wright, Tim

    2015-02-26

    Strong links exist between deprivation, obesity, and dietary quality. Increasing interest has focussed on the concept of access to food and so-called food deserts, defined by a policy working group of the UK Low Income Project Team in 1995 as "areas of relative exclusion where people experience physical and economic barriers to accessing healthy food". We aimed to establish the accessibility of food retail outlets in County Durham, a county in north-east England, UK, considering physical access, affordability, and food range and quality. In a pragmatic cross-sectional study in County Durham, we used information from town surveys and food business databases to locate and identify food retail outlets. The prevalence of deprivation, obesity, retail outlets, takeaway outlets, and ratio of retail to takeaway outlets was mapped, to establish local food access, and any associations with deprivation and obesity. The times taken to travel from residences to supermarkets using private car and public transport were also measured. 400 members of the community participated in eight focus groups and commissioned on-street surveys. Focus group transcripts were reviewed alongside the on-street survey responses to identify key issues. Most residents shopped at least weekly for food (n=368, 92%), used a supermarket for their main food shop (372, 93%), travelled for up to 15 min (340, 85%), and used a car for transport (188, 47%). Many survey respondents indicated high levels of satisfaction with food retail outlets (average rating 8·7 out of 10 for agreement with the statement "Overall I am satisfied with the shop where I do my main food shopping"), although financial constraints and transport inconvenience were identified as barriers. Difficulties with food shopping were more widely described in focus groups, and many individuals felt that local shopping provision had declined, with an emergent excess of takeaway outlets. Food retail access was reduced for the disabled, full

  17. Local concentration of fast-food outlets is associated with poor nutrition and obesity.

    PubMed

    Kruger, Daniel J; Greenberg, Emily; Murphy, Jillian B; DiFazio, Lindsay A; Youra, Kathryn R

    2014-01-01

    We investigated the relationship of the local availability of fast-food restaurant locations with diet and obesity. We geocoded addresses of survey respondents and fast-food restaurant locations to assess the association between the local concentration of fast-food outlets, BMI, and fruit and vegetable consumption. The survey was conducted in Genesee County, Michigan. There were 1345 individuals included in this analysis, and the response rate was 25%. The Speak to Your Health! Community Survey included fruit and vegetable consumption items from the Behavioral Risk Factor Surveillance System, height, weight, and demographics. We used ArcGIS to map fast-food outlets and survey respondents. Stepwise linear regressions identified unique predictors of body mass index (BMI) and fruit and vegetable consumption. Survey respondents had 8 ± 7 fast-food outlets within 2 miles of their home. Individuals living in close proximity to fast-food restaurants had higher BMIs t(1342) = 3.21, p < .001, and lower fruit and vegetable consumption, t(1342) = 2.67, p = .008. Individuals may be at greater risk for adverse consequences of poor nutrition because of the patterns in local food availability, which may constrain the success of nutrition promotion efforts. Efforts to decrease the local availability of unhealthy foods as well as programs to help consumers identify strategies for obtaining healthy meals at fast-food outlets may improve health outcomes.

  18. The molecular genetic basis of mitochondrial malfunction in bladder tissue following outlet obstruction.

    PubMed

    Levin, Robert M; Hudson, Alan P

    2004-08-01

    Bladder dysfunction following partial outlet obstruction is a frequent consequence of benign prostatic hyperplasia and an increasingly common problem given the aging of the general population. Recent studies from this and other groups have begun to elucidate the molecular bases for the well described physiological malfunctions that characterize this clinical entity. We summarized and synthesized that information. Using modern methods of molecular genetics, including real-time polymerase chain reaction, real-time reverse transcriptase-polymerase chain reaction and others, as well as traditional experimental techniques such as electron microscopy we and others examined the transcriptional profile, morphology, etc of bladder smooth muscle mitochondria in experimental models of outlet obstruction. Data from many studies have demonstrated that aberrant gene expression in the mitochondrial and mitochondria related nuclear genetic systems underlies the loss of compliance and other attributes of bladder dysfunction following outlet obstruction. Such aberrant transcriptional characteristics engender loss of function in the electron transport and oxidative phosphorylation systems. Morphological studies of mitochondria in the animal model systems support this conclusion. In large part the loss of function in bladder smooth muscle following outlet obstruction results from the attenuation of mitochondrial energy production. In this article we reviewed and synthesized all available experimental observations relevant to this problem and we suggest future lines of inquiry that should prove fruitful in developing new strategies to treat the condition.

  19. The Impact of Alcohol Outlet Density on the Geographic Clustering of Underage Drinking Behaviors within Census Tracts

    PubMed Central

    Reboussin, Beth A.; Song, Eun-Young; Wolfson, Mark

    2011-01-01

    Background The regulation of alcohol outlet density has been considered as a potential means of reducing alcohol consumption and related harms among underage youth. Whereas prior studies have examined whether alcohol outlet density was associated with an individual’s alcohol consumption and related harms, this study examines whether it is related to the co-occurrence, or clustering, of these behaviors within geographic areas, specifically census tracts. Methods The Enforcing Underage Drinking Laws Randomized Community Trial provided cross-sectional telephone survey data in 2006 and 2007 from 10,754 youth aged 14–20 from 5 states residing in 1556 census tracts. The alternating logistic regression approach was used to estimate pairwise odds ratios between responses from youth residing in the same census tract and to model them as a function of alcohol outlet density. Results Riding with a drinking driver, making an alcohol purchase attempt and making a successful alcohol purchase attempt clustered significantly within census tracts with the highest off-premise alcohol outlet density while frequent drinking clustered within census tracts with the greatest on-premise density. Driving after drinking and experiencing non-violent alcohol-related consequences clustered marginally within census tracts with the greatest on-premise and off-premise alcohol outlet density, respectively. Conclusions Although youth primarily receive alcohol from social sources, commercial alcohol access is geographically concentrated within census tracts with the greatest off-premise outlet density. A potentially greater concern is the clustering of more frequent drinking and drinking and driving within census tracts with the greatest on-premise outlet density which may necessitate alternative census tract level initiatives to reduce these potentially harmful behaviors. PMID:21463343

  20. 17. VIEW TO NORTH SHOWING FISH WATER RELEASE OUTLET AS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    17. VIEW TO NORTH SHOWING FISH WATER RELEASE OUTLET AS WELL AS SOUTHWEST AND SOUTHEAST ELEVATIONS OF FLOAT HOUSE. - Pit 4 Diversion Dam, Pit River west of State Highway 89, Big Bend, Shasta County, CA

  1. 8. DETAIL VIEW OF INCLINED OUTLET GATE WHEEL, LOOKING EAST ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    8. DETAIL VIEW OF INCLINED OUTLET GATE WHEEL, LOOKING EAST - High Mountain Dams in Upalco Unit, Kidney Lake Dam, Ashley National Forest, 4.7 miles North of Miners Gulch Campground, Mountain Home, Duchesne County, UT

  2. 5. VIEW OF OUTLET GATE WHEEL AND STEM, LOOKING NORTH ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. VIEW OF OUTLET GATE WHEEL AND STEM, LOOKING NORTH - High Mountain Dams in Upalco Unit, Island Lake Dam, Ashley National Forest, 4.8 miles North of Miners Gulch Campground, Mountain Home, Duchesne County, UT

  3. 4. VIEW SHOWING OUTLET GATE WHEEL AND STEM, LOOKING NORTH ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    4. VIEW SHOWING OUTLET GATE WHEEL AND STEM, LOOKING NORTH - High Mountain Dams in Upalco Unit, Clements Lake Dam, Ashley National Forest, 6.5 miles North of Miners Gulch Campground, Mountain Home, Duchesne County, UT

  4. 40 CFR 63.1106 - Wastewater provisions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 10 2010-07-01 2010-07-01 false Wastewater provisions. 63.1106 Section 63.1106 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED... Technology Standards § 63.1106 Wastewater provisions. (a) Process wastewater. Except as specified in...

  5. Working with Media Outlets To Communicate with the Public.

    ERIC Educational Resources Information Center

    Wallace, Mark L.

    2000-01-01

    Offers suggestions from a veteran public relations practitioner on how colleges can effectively use media resources to advertise academic programs, workforce training, and continuing education opportunities. Focuses on maximizing the benefits of using these five media outlets: newspapers, radio and TV, direct mail, the Internet, and cable…

  6. Simulation of a proposed emergency outlet from Devils Lake, North Dakota

    USGS Publications Warehouse

    Vecchia, Aldo V.

    2002-01-01

    From 1993 to 2001, Devils Lake rose more than 25 feet, flooding farmland, roads, and structures around the lake and causing more than $400 million in damages in the Devils Lake Basin. In July 2001, the level of Devils Lake was at 1,448.0 feet above sea level1, which was the highest lake level in more than 160 years. The lake could continue to rise to several feet above its natural spill elevation to the Sheyenne River (1,459 feet above sea level) in future years, causing extensive additional flooding in the basin and, in the event of an uncontrolled natural spill, downstream in the Red River of the North Basin as well. The outlet simulation model described in this report was developed to determine the potential effects of various outlet alternatives on the future lake levels and water quality of Devils Lake.Lake levels of Devils Lake are controlled largely by precipitation on the lake surface, evaporation from the lake surface, and surface inflow. For this study, a monthly water-balance model was developed to compute the change in total volume of Devils Lake, and a regression model was used to estimate monthly water-balance data on the basis of limited recorded data. Estimated coefficients for the regression model indicated fitted precipitation on the lake surface was greater than measured precipitation in most months, fitted evaporation from the lake surface was less than estimated evaporation in most months, and ungaged inflow was about 2 percent of gaged inflow in most months. Dissolved sulfate was considered to be the key water-quality constituent for evaluating the effects of a proposed outlet on downstream water quality. Because large differences in sulfate concentrations existed among the various bays of Devils Lake, monthly water-balance data were used to develop detailed water and sulfate mass-balance models to compute changes in sulfate load for each of six major storage compartments in response to precipitation, evaporation, inflow, and outflow from

  7. Cold plate

    DOEpatents

    Marroquin, Christopher M.; O'Connell, Kevin M.; Schultz, Mark D.; Tian, Shurong

    2018-02-13

    A cold plate, an electronic assembly including a cold plate, and a method for forming a cold plate are provided. The cold plate includes an interface plate and an opposing plate that form a plenum. The cold plate includes a plurality of active areas arranged for alignment over respective heat generating portions of an electronic assembly, and non-active areas between the active areas. A cooling fluid flows through the plenum. The plenum, at the non-active areas, has a reduced width and/or reduced height relative to the plenum at the active areas. The reduced width and/or height of the plenum, and exterior dimensions of cold plate, at the non-active areas allow the non-active areas to flex to accommodate surface variations of the electronics assembly. The reduced width and/or height non-active areas can be specifically shaped to fit between physical features of the electronics assembly.

  8. 7. VIEW OF INCLINED OUTLET GATE WHEEL AND STEM, LOOKING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    7. VIEW OF INCLINED OUTLET GATE WHEEL AND STEM, LOOKING NORTH - High Mountain Dams in Upalco Unit, Kidney Lake Dam, Ashley National Forest, 4.7 miles North of Miners Gulch Campground, Mountain Home, Duchesne County, UT

  9. 6. VIEW OF SHOWING DOWNSTREAM OUTLET PIPE AND COLLAR (12' ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    6. VIEW OF SHOWING DOWNSTREAM OUTLET PIPE AND COLLAR (12' DIAMETER CORRUGATED STEEL PIPE ENCASED IN 6' CONCRETE), LOOKING NORTH - High Mountain Dams in Bonneville Unit, Island Lake Dam, Wasatch National Forest, Kamas, Summit County, UT

  10. 5. VIEW OF UPRIGHT OUTLET GATE, STEM, STEM GUIDE AND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. VIEW OF UPRIGHT OUTLET GATE, STEM, STEM GUIDE AND WHEEL (10' HARDESTY CAST IRON VERTICAL LIFT GATE), LOOKING WEST - High Mountain Dams in Bonneville Unit, Weir Lake Dam, Wasatch National Forest, Kamas, Summit County, UT

  11. 5. VIEW OF INCLINED OUTLET GATE WHEEL, STEM AND STEM ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. VIEW OF INCLINED OUTLET GATE WHEEL, STEM AND STEM GUIDE, (12' DIAMETER HARDESTY MODEL 112 CIRCULAR GATE), LOOKING NORTHEAST - High Mountain Dams in Bonneville Unit, Island Lake Dam, Wasatch National Forest, Kamas, Summit County, UT

  12. 5. VIEW SHOWING INCLINED OUTLET GATE WHEEL, STEM AND STEM ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. VIEW SHOWING INCLINED OUTLET GATE WHEEL, STEM AND STEM GUIDE (28' WIDE HARDESTY CAST IRON SLIDE HEADGATE), LOOKING NORTHEAST - High Mountain Dams in Bonneville Unit, Duck Lake Dam, Wasatch National Forest, Kamas, Summit County, UT

  13. 8. VIEW OF DOWNSTREAM OUTLET CULVERT AND WING RETAINING WALLS, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    8. VIEW OF DOWNSTREAM OUTLET CULVERT AND WING RETAINING WALLS, LOOKING NORTHWEST - High Mountain Dams in Upalco Unit, Twin Pots Dam, Ashley National Forest, 10.1 miles North of Mountain Home, Mountain Home, Duchesne County, UT

  14. Effects of Orifice-Weir Outlet on Hydrology and Water Quality of a Drained Forested Watershed

    Treesearch

    Devendra M. Amatya; R. Wayne Skaggs; J.W. Gilliam; J.H. Hughes

    2003-01-01

    Orifice-weir structures at ditch outlets are proposed to reduce peak drainage rates during high flows and to store water during the growing season in poorly drained managed pine plantations. Two coastal watersheds, one conventionally drained (D1) and another with an orifice-weir outlet (D3), were monitored to examine the effects of this orifice treatment on drainage...

  15. Explicit Simulation of Networks of Outlet Glaciers to Constrain Greenland's Sea Level Contribution

    NASA Astrophysics Data System (ADS)

    Ultee, E.; Bassis, J. N.

    2017-12-01

    Ice from the Greenland Ice Sheet drains to the ocean through hundreds of outlet glaciers, many of which are too small to be accurately resolved in continental-scale ice sheet models. Moreover, despite the fact that dynamic changes in Greenland outlet glaciers are currently responsible for about half of the ice sheet's contribution to global sea level, all but the largest are often excluded from major sea level assessments. We have previously developed and validated a simple model that simulates advance and retreat of networks of marine-terminating glaciers based on the perfect plastic approximation. Here we apply this model to a selection of forcing scenarios, representing both climate persistence and extreme scenarios, to constrain changes in calving flux from the most significant Greenland outlet glaciers. Our model can be implemented in standalone mode or as the calving module in a more sophisticated large-scale model, providing constraints on Greenland's future contribution to global sea level rise under a range of scenarios.

  16. Effects of wastewater on forested wetlands

    USGS Publications Warehouse

    Doyle, Thomas W.

    2002-01-01

    Cycling nutrient-enriched wastewater from holding ponds through natural, forested wetlands is a practice that municipal waste treatment managers are considering as a viable option for disposing of wastewater. In this wastewater cycling process, sewer effluent that has been circulated through aerated ponds is discharged into neighboring wetland systems. To understand how wastewater cycling affects forest and species productivity, researchers at the USGS National Wetlands Research Center conducted dendroecological investigations in a swamp system and in a bog system that have been exposed to wastewater effluent for many decades. Dendroecology involves the study of forest changes over time as interpreted from tree rings. Tree-ring chronologies describe the pattern and history of growth suppression and release that can be associated with aging and disturbances such as hurricanes, floods, and fires. But because of limited monitoring, little is known about the potential for long-term effects on forested wetlands as a result of wastewater flooding. USGS researchers used tree rings to detect the effect of wastewater cycling on tree growth. Scientists expected to find that tree-ring width would be increased as a result of added nutrients.

  17. Changes in hormone and stress-inducing activities of municipal wastewater in a conventional activated sludge wastewater treatment plant.

    PubMed

    Wojnarowicz, Pola; Yang, Wenbo; Zhou, Hongde; Parker, Wayne J; Helbing, Caren C

    2014-12-01

    Conventional municipal wastewater treatment plants do not efficiently remove contaminants of emerging concern, and so are primary sources for contaminant release into the aquatic environment. Although these contaminants are present in effluents at ng-μg/L concentrations (i.e. microcontaminants), many compounds can act as endocrine disrupting compounds or stress-inducing agents at these levels. Chemical fate analyses indicate that additional levels of wastewater treatment reduce but do not always completely remove all microcontaminants. The removal of microcontaminants from wastewater does not necessarily correspond to a reduction in biological activity, as contaminant metabolites or byproducts may still be biologically active. To evaluate the efficacy of conventional municipal wastewater treatment plants to remove biological activity, we examined the performance of a full scale conventional activated sludge municipal wastewater treatment plant located in Guelph, Ontario, Canada. We assessed reductions in levels of conventional wastewater parameters and thyroid hormone disrupting and stress-inducing activities in wastewater at three phases along the treatment train using a C-fin assay. Wastewater treatment was effective at reducing total suspended solids, chemical and biochemical oxygen demand, and stress-inducing bioactivity. However, only minimal reduction was observed in thyroid hormone disrupting activities. The present study underscores the importance of examining multiple chemical and biological endpoints in evaluating and monitoring the effectiveness of wastewater treatment for removal of microcontaminants. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. 4. VIEW OF INCLINED OUTLET GATE WHEEL AND STEM, LOOKING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    4. VIEW OF INCLINED OUTLET GATE WHEEL AND STEM, LOOKING NORTHWEST - High Mountain Dams in Upalco Unit, Brown Duck Lake Dam, Ashley National Forest, 4.4 miles North of Miners Gulch Campground, Mountain Home, Duchesne County, UT

  19. 7. VIEW OF UPRIGHT OUTLET GATE, WHEEL STEM AND STEM ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    7. VIEW OF UPRIGHT OUTLET GATE, WHEEL STEM AND STEM GUIDE (14' DIAMETER CIRCULAR CALCO CAST IRON SLIDE GATE), LOOKING SOUTHEAST - High Mountain Dams in Bonneville Unit, Fire Lake Dam, Wasatch National Forest, Kamas, Summit County, UT

  20. 4. AERIAL VIEW OF DAM SITE SHOWING OUTLET WORKS AND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    4. AERIAL VIEW OF DAM SITE SHOWING OUTLET WORKS AND DIVERSION CHANNEL IN FOREGROUND.... Volume XVIII, No. 9, March 5, 1940. - Prado Dam, Santa Ana River near junction of State Highways 71 & 91, Corona, Riverside County, CA