Physiological and subjective responses to standing showers, sitting showers, and sink baths.
Ohnaka, T; Tochihara, Y; Kubo, M; Yamaguchi, C
1995-09-01
The purpose of this study was to investigate physiological and subjective responses during and after bathing in three different bathing methods. Eight healthy males bathed for 10 minutes, and then rested for 30 minutes. Three kinds of bathing methods - standing shower, sitting shower and sink bath - were adopted in this experiment. Water temperature and flow volume of the showers were kept at 41 degrees C and 11 liter/min, while water temperature of the bath was kept at 40 degrees C. Rectal temperature, skin temperatures and heart rate of the subjects were measured continuously during bathing and the subsequent 30-minute rest. Blood pressure and votes for thermal sensations were recorded before bathing, after 5 and 10 minutes of bathing, and 5, 10, 20 and 30 minutes after bathing. The following results were obtained. 1) Although rectal temperature rose, on the average, by 0.15 degrees C in all bathing methods, there were no significant differences among the three bathing methods at any time in the experiment. 2) Mean skin temperature (Tsk) during the sink bath was significantly higher than that in the standing or sitting shower. After bathing, Tsk of sink bath was slightly higher than those of the remaining conditions, but did not significantly differ among the bathing methods. 3) Heart rate increased gradually during all the bathing methods, however, only HR in the standing shower exceeded 100 beats/min which was significantly higher than those of the two remaining bathing methods. 4) Blood pressure (BP) decreased rapidly during the sink bath in contrast to an increased BP in the sitting and standing showers.
Eckner, Karl F.
1998-01-01
A total of 338 water samples, 261 drinking water samples and 77 bathing water samples, obtained for routine testing were analyzed in duplicate by Swedish standard methods using multiple-tube fermentation or membrane filtration and by the Colilert and/or Enterolert methods. Water samples came from a wide variety of sources in southern Sweden (Skåne). The Colilert method was found to be more sensitive than Swedish standard methods for detecting coliform bacteria and of equal sensitivity for detecting Escherichia coli when all drinking water samples were grouped together. Based on these results, Swedac, the Swedish laboratory accreditation body, approved for the first time in Sweden use of the Colilert method at this laboratory for the analysis of all water sources not falling under public water regulations (A-krav). The coliform detection study of bathing water yielded anomalous results due to confirmation difficulties. E. coli detection in bathing water was similar by both the Colilert and Swedish standard methods as was fecal streptococcus and enterococcus detection by both the Enterolert and Swedish standard methods. PMID:9687478
Inoue, Hiroaki; Takama, Tomoko; Yoshizaki, Miwa; Agata, Kunio
2015-01-01
We detected Legionella species in 111 bath water samples and 95 cooling tower water samples by using a combination of conventional plate culture, quantitative polymerase chain reaction (qPCR) and qPCR combined with ethidium monoazide treatment (EMA-qPCR) methods. In the case of bath water samples, Legionella spp. were detected in 30 samples by plate culture, in 85 samples by qPCR, and in 49 samples by EMA-qPCR. Of 81 samples determined to be Legionella-negative by plate culture, 56 and 23 samples were positive by qPCR and EMA-qPCR, respectively. Therefore, EMA treatment decreased the number of Legionella-positive bath water samples detected by qPCR. In contrast, EMA treatment had no effect on cooling tower water samples. We therefore expect that EMA-qPCR is a useful method for the rapid detection of viable Legionella spp. from bath water samples.
Papaioannou, Agelos; Rigas, George; Papastergiou, Panagiotis; Hadjichristodoulou, Christos
2014-12-02
Worldwide, the aim of managing water is to safeguard human health whilst maintaining sustainable aquatic and associated terrestrial, ecosystems. Because human enteric viruses are the most likely pathogens responsible for waterborne diseases from recreational water use, but detection methods are complex and costly for routine monitoring, it is of great interest to determine the quality of coastal bathing water with a minimum cost and maximum safety. This study handles the assessment and modelling of the microbiological quality data of 2149 seawater bathing areas in Greece over 10-year period (1997-2006) by chemometric methods. Cluster analysis results indicated that the studied bathing beaches are classified in accordance with the seasonality in three groups. Factor analysis was applied to investigate possible determining factors in the groups resulted from the cluster analysis, and also two new parameters were created in each group; VF1 includes E. coli, faecal coliforms and total coliforms and VF2 includes faecal streptococci/enterococci. By applying the cluster analysis in each seasonal group, three new groups of coasts were generated, group A (ultraclean), group B (clean) and group C (contaminated). The above analysis is confirmed by the application of discriminant analysis, and proves that chemometric methods are useful tools for assessment and modeling microbiological quality data of coastal bathing water on a large scale, and thus could attribute to effective and economical monitoring of the quality of coastal bathing water in a country with a big number of bathing coasts, like Greece. Significance for public healthThe microbiological protection of coastal bathing water quality is of great interest for the public health authorities as well as for the economy. The present study proves that this protection can be achieved by monitoring only two microbiological parameters, E. coli and faecal streptococci/enterococci instead four microbiological parameters (the two mentioned above plus Total coliforms and Faecal coliforms) that are usually monitored today. As a consequence, countries, especially those with large quantities of coastal bathing sites, can perform microbiological monitoring of their bathing waters by checking only the mentioned two parameters, thus ensuring economies of scale. Thus, funds can be used in other actions to preserve the quality of coastal water and human health. This in turn, would aid in the assessment of the quality of coastal bathing waters and provide a more timely indication of bathing water quality, hence contributing to the immediate health protection of bathers.
Oliver, David M; Hanley, Nick D; van Niekerk, Melanie; Kay, David; Heathwaite, A Louise; Rabinovici, Sharyl J M; Kinzelman, Julie L; Fleming, Lora E; Porter, Jonathan; Shaikh, Sabina; Fish, Rob; Chilton, Sue; Hewitt, Julie; Connolly, Elaine; Cummins, Andy; Glenk, Klaus; McPhail, Calum; McRory, Eric; McVittie, Alistair; Giles, Amanna; Roberts, Suzanne; Simpson, Katherine; Tinch, Dugald; Thairs, Ted; Avery, Lisa M; Vinten, Andy J A; Watts, Bill D; Quilliam, Richard S
2016-02-01
The use of molecular tools, principally qPCR, versus traditional culture-based methods for quantifying microbial parameters (e.g., Fecal Indicator Organisms) in bathing waters generates considerable ongoing debate at the science-policy interface. Advances in science have allowed the development and application of molecular biological methods for rapid (~2 h) quantification of microbial pollution in bathing and recreational waters. In contrast, culture-based methods can take between 18 and 96 h for sample processing. Thus, molecular tools offer an opportunity to provide a more meaningful statement of microbial risk to water-users by providing near-real-time information enabling potentially more informed decision-making with regard to water-based activities. However, complementary studies concerning the potential costs and benefits of adopting rapid methods as a regulatory tool are in short supply. We report on findings from an international Working Group that examined the breadth of social impacts, challenges, and research opportunities associated with the application of molecular tools to bathing water regulations.
Whitney, Jon; Carswell, William; Rylander, Nichole
2013-06-01
Predictions of injury in response to photothermal therapy in vivo are frequently made using Arrhenius parameters obtained from cell monolayers exposed to laser or water bath heating. However, the impact of different heating methods and cellular microenvironments on Arrhenius predictions has not been thoroughly investigated. This study determined the influence of heating method (water bath and laser irradiation) and cellular microenvironment (cell monolayers and tissue phantoms) on Arrhenius parameters and spatial viability. MDA-MB-231 cells seeded in monolayers and sodium alginate phantoms were heated with a water bath for 3-20 min at 46, 50, and 54 °C or laser irradiated (wavelength of 1064 nm and fluences of 40 W/cm(2) or 3.8 W/cm(2) for 0-4 min) in combination with photoabsorptive carbon nanohorns. Spatial viability was measured using digital image analysis of cells stained with calcein AM and propidium iodide and used to determine Arrhenius parameters. The influence of microenvironment and heating method on Arrhenius parameters and capability of parameters derived from more simplistic experimental conditions (e.g. water bath heating of monolayers) to predict more physiologically relevant systems (e.g. laser heating of phantoms) were assessed. Arrhenius predictions of the treated area (<1% viable) under-predicted the measured areas in photothermally treated phantoms by 23 mm(2) using water bath treated cell monolayer parameters, 26 mm(2) using water bath treated phantom parameters, 27 mm(2) using photothermally treated monolayer parameters, and 0.7 mm(2) using photothermally treated phantom parameters. Heating method and cellular microenvironment influenced Arrhenius parameters, with heating method having the greater impact.
Santos, Inês C; Mesquita, Raquel B R; Bordalo, Adriano A; Rangel, António O S S
2015-02-01
The present work describes the development of a sequential injection standard addition method for iodine speciation in bathing waters and seaweeds extracts without prior sample treatment. Iodine speciation was obtained by assessing the iodide and iodate content, the two inorganic forms of iodine in waters. For the determination of iodide, an iodide ion selective electrode (ISE) was used. The indirect determination of iodate was based on the spectrophotometric determination of nitrite (Griess reaction). For the iodate measurement, a mixing chamber was employed (flow batch approach) to explore the inherent efficient mixing, essential for the indirect determination of iodate. The application of the standard addition method enabled detection limits of 0.14 µM for iodide and 0.02 µM for iodate, together with the direct introduction of the target water samples, coastal and inland bathing waters. The results obtained were in agreement with those obtained by ICP-MS and a colorimetric reference procedure. Recovery tests also confirmed the accuracy of the developed method which was effectively applied to bathing waters and seaweed extracts. Copyright © 2014 Elsevier B.V. All rights reserved.
Water bath accelerated curing of concrete.
DOT National Transportation Integrated Search
1970-01-01
Water bath methods for accelerating the strength development of portland cement concrete were investigated in a two phase study as follows. Phase I - Participation in a cooperative accelerated strength testing program sponsored by the American Societ...
Extreme value theory applied to the definition of bathing water quality discounting limits.
Haggarty, R A; Ferguson, C A; Scott, E M; Iroegbu, C; Stidson, R
2010-02-01
The European Community Bathing Water Directive (European Parliament, 2006) set compliance standards for bathing waters across Europe, with minimum standards for microbiological indicators to be attained at all locations by 2015. The Directive allows up to 15% of samples affected by short-term pollution episodes to be disregarded from the figures used to classify bathing waters, provided certain management criteria have been met, including informing the public of short-term water pollution episodes. Therefore, a scientifically justifiable discounting limit is required which could be used as a management tool to determine the samples that should be removed. This paper investigates different methods of obtaining discounting limits, focusing in particular on extreme value methodology applied to data from Scottish bathing waters. Return level based limits derived from threshold models applied at a site-specific level improved the percentage of sites which met at least the minimum required standard. This approach provides a method of obtaining limits which identify the samples that should be removed from compliance calculations, although care has to be taken in terms of the quantity of data which is removed. (c) 2009 Elsevier Ltd. All rights reserved.
Soil is the origin for the presence of Naegleria fowleri in the thermal recreational waters.
Moussa, Mirna; Tissot, Océane; Guerlotté, Jérôme; De Jonckheere, Johan F; Talarmin, Antoine
2015-01-01
Naegleria fowleri is found in most geothermal baths of Guadeloupe and has been responsible for the death of a 9-year-old boy who swam in one of these baths in 2008. We wanted to determine the origin for the presence of this amoeba in the water. Water samples were taken at the origin of the geothermal sources and at the arrival in the baths. After filtration, cultures were made and the number of Naegleria present was determined using the most probable number method. Soil samples collected in the proximity of the baths were also tested for the presence of thermophilic amoebae. The species identification was obtained by PCR. During three consecutive months, no Naegleria could be found at the origin of any geothermal source tested. In contrast, N. fowleri was isolated at least once in all baths at the arrival of the water, except one. Thermophilic amoebae could be found in each soil sample, especially near the baths located at a lower altitude, but N. fowleri was only isolated near two baths, which were also the baths most often contaminated with this species. So it appears that the contamination of the water with N. fowleri occurs after emerging from the geothermal source when the water runs over the soil. Therefore, it should be possible to reduce the concentration of N. fowleri in the geothermal baths of Guadeloupe to for example less than 1 N. fowleri/10 L by installing a pipeline between the geothermal sources and the baths and by preventing flooding water from entering the baths after rainfall. By taking these measures, we were able to eliminate N. fowleri from a pool located inside a reeducation clinic.
Elahi, Ehsan; Abid, Muhammad; Zhang, Huiming; Cui, Weijun; Ul Hasson, Shabeh
2018-06-01
Given the shortage and non-availability of freshwater in Pakistan, wastewater is being used for bathing water buffaloes; however, this has a negative impact on animal welfare. Although there is a vast literature on indirect linkages between wastewater and animal productivity, studies focusing on the direct impacts of water buffaloes bathing in wastewater on animal productivity and economic losses are rare. Therefore, using 360 domestic water buffalo farms, this study examines the expenditure and production losses associated with bathing (in wastewater and freshwater) and non-bathing water buffaloes by employing partial budgeting and resource adjustment component techniques. Furthermore, it investigates the prevalence of animal diseases and associated economic effects using correlation analysis and propensity score matching techniques, respectively. The findings reveal that compared to their counterparts (freshwater bathing and non-bathing water buffaloes), buffaloes bathing in wastewater are at increased risk of clinical mastitis, foot and mouth disease (FMD) and tick infestation. Moreover, the use of wastewater for bathing buffaloes also leads to higher economic and production losses by affecting milk productivity, causing premature culling, and reducing slaughter value. The findings of the double-log model show that economic losses are higher if buffaloes bathe in wastewater within 30 min after milking, as there are more chances that those buffaloes would be exposed to bacterial penetration in the teat ducts, which may result in intramammary infection. According to the propensity score matching method, the higher economic damages per month are associated with buffaloes bathing in wastewater and freshwater, 155 and 110 USD per farm, respectively. The study findings reference the need for policies to restrict wastewater access by water buffaloes, and a regular check of and access to cool clean water wallows for bathing during hot summer days, to reduce excess heat and economic losses, and thus improve animal welfare. Copyright © 2018 Elsevier B.V. All rights reserved.
Wort free amino nitrogen analysis adapted to a microplate format
USDA-ARS?s Scientific Manuscript database
The standard method for determining wort free amino nitrogen content calls for the use of test tubes and glass marbles, as well as boiling and 20°C water baths. In this paper we describe how the standard method can be updated and streamlined by replacing water baths, test tubes and marbles with a th...
Sattar, Anas A; Jackson, Simon K; Bradley, Graham
2014-03-01
The use of total lipopolysaccharide (LPS) as a rapid biomarker for bacterial pollution was investigated at a bathing and surfing beach during the UK bathing season. The levels of faecal indicator bacteria Escherichia coli (E. coli), the Gram-positive enterococci, and organisms commonly associated with faecal material, such as total coliforms and Bacteroides, were culturally monitored over four months to include a period of heavy rainfall and concomitant pollution. Endotoxin measurement was performed using a kinetic Limulus Amebocyte Lysate (LAL) assay and found to correlate well with all indicators. Levels of LPS in excess of 50 Endotoxin Units (EU) mL(-1) were found to correlate with water that was unsuitable for bathing under the current European regulations. Increases in total LPS, mainly from Gram-negative indicator bacteria, are thus a potential real-time, qualitative method for testing bacterial quality of bathing waters.
Safety of tomatillos and products containing tomatillos canned by the water-bath canning method.
McKee, L H; Remmenga, M D; Bock, M A
1998-01-01
Three studies were conducted to evaluate the safety of tomatillos and products containing tomatillos canned by the water-bath processing method. In the first study, plain tomatillos were processed for 25, 37.5, 50 and 62.5 min. In the second study, five tomatillo/onion combinations were prepared while five tomatillo/green chile combinations were prepared in the third study. pH evaluations were conducted to determine safety in all studies using pH 4.2 as the cut-off value. No differences in the pH of plain tomatillos were detected due to processing time. All jars of plain tomatillos had pH values below 4.1. All combinations of tomatillos/onions and tomatillos/green chile containing more than 50% tomatillo had pH values below the 4.2 cut-off value. Results of the three studies indicate (1) acidification of plain tomatillos is probably unnecessary for canning by the water-bath processing method and (2) combinations of acidic tomatillos and low-acid onions or green chile must contain more than 50% tomatillos to have a pH low enough for safe water-bath processing.
Bacterial adherence to hydrocarbons, BATH, is a method for determining the hydrophobic surface characteristics of bacterial cells. The strain’s affinity for water is evaluated by thoroughly mixing a culture and hydrocarbon suspension and then evaluating the decrease in optical de...
Ugly ducklings-the dark side of plastic materials in contact with potable water.
Neu, Lisa; Bänziger, Carola; Proctor, Caitlin R; Zhang, Ya; Liu, Wen-Tso; Hammes, Frederik
2018-01-01
Bath toys pose an interesting link between flexible plastic materials, potable water, external microbial and nutrient contamination, and potentially vulnerable end-users. Here, we characterized biofilm communities inside 19 bath toys used under real conditions. In addition, some determinants for biofilm formation were assessed, using six identical bath toys under controlled conditions with either clean water prior to bathing or dirty water after bathing. All examined bath toys revealed notable biofilms on their inner surface, with average total bacterial numbers of 5.5 × 10 6 cells/cm 2 (clean water controls), 9.5 × 10 6 cells/cm 2 (real bath toys), and 7.3 × 10 7 cells/cm 2 (dirty water controls). Bacterial community compositions were diverse, showing many rare taxa in real bath toys and rather distinct communities in control bath toys, with a noticeable difference between clean and dirty water control biofilms. Fungi were identified in 58% of all real bath toys and in all dirty water control toys. Based on the comparison of clean water and dirty water control bath toys, we argue that bath toy biofilms are influenced by (1) the organic carbon leaching from the flexible plastic material, (2) the chemical and biological tap water quality, (3) additional nutrients from care products and human body fluids in the bath water, as well as, (4) additional bacteria from dirt and/or the end-users' microbiome. The present study gives a detailed characterization of bath toy biofilms and a better understanding of determinants for biofilm formation and development in systems comprising plastic materials in contact with potable water.
Hard water softening effect of a baby cleanser
Walters, Russel M; Anim-Danso, Emmanuel; Amato, Stephanie M; Capone, Kimberly A; Mack, M Catherine; Telofski, Lorena S; Mays, David A
2016-01-01
Background Hard water is associated with atopic dermatitis (eczema). We wanted to determine if a baby cleanser and its individual components altered free ionized calcium (Ca2+) in a simulated hard water baby bath. For these studies, an in vitro determination of free Ca2+ in a simulated hard water baby bath, and an in vivo exploratory study of free Ca2+ absorption into skin from hard water were performed. Methods Free Ca2+ was measured with an ion-sensitive electrode in vitro in hard water (100–500 ppm, Ca2+) before and after addition of the cleanser and/or its components. In an exploratory study, absorption of Ca2+ into skin from hard water was determined in three female participants (aged 21–29 years). Results At an in-use dilution of 1%, the test cleanser reduced free Ca2+ from ~500 ppm to <200 ppm; a 10% in-use dilution bound virtually all free Ca2+. The anionic surfactant component contributed the most to this effect. In the exploratory in vivo study, we measured a reduction of ~15% in free Ca2+ from simulated hard water over 10 minutes. Conclusion Baby cleansers can bind free Ca2+ and reduce the effective water hardness of bath water. Reducing the amount of free Ca2+ in the water will reduce the availability of the ion for binding to the skin. Altering or reducing free Ca2+ concentrations in bath water may be an important parameter in creating the ideal baby bath. PMID:27789967
Lima, Ana Paula Barbosa; Vitti, Rafael Pino; Amaral, Marina; Neves, Ana Christina Claro; da Silva Concilio, Lais Regiane
2018-04-01
This study evaluated the dimensional stability of a complete-arch prosthesis processed by conventional method in water bath or microwave energy and polymerized by two different curing cycles. Forty maxillary complete-arch prostheses were randomly divided into four groups (n = 10): MW1 - acrylic resin cured by one microwave cycle; MW2 - acrylic resin cured by two microwave cycles: WB1 - conventional acrylic resin polymerized using one curing cycle in a water bath; WB2 - conventional acrylic resin polymerized using two curing cycles in a water bath. For evaluation of dimensional stability, occlusal vertical dimension (OVD) and area of contact points were measured in two different measurement times: before and after the polymerization method. A digital caliper was used for OVD measurement. Occlusal contact registration strips were used between maxillary and mandibular dentures to measure the contact points. The images were measured using the software IpWin32, and the differences before and after the polymerization methods were calculated. The data were statistically analyzed using the one-way ANOVA and Tukey test (α = .05). he results demonstrated significant statistical differences for OVD between different measurement times for all groups. MW1 presented the highest OVD values, while WB2 had the lowest OVD values ( P <.05). No statistical differences were found for area of contact points among the groups ( P =.7150). The conventional acrylic resin polymerized using two curing cycles in a water bath led to less difference in OVD of complete-arch prosthesis.
Edagawa, Akiko; Kimura, Akio; Kawabuchi-Kurata, Takako; Adachi, Shinichi; Furuhata, Katsunori; Miyamoto, Hiroshi
2015-10-19
We investigated Legionella contamination in bath water samples, collected from 68 bathing facilities in Japan, by culture, culture with amoebic co-culture, real-time quantitative PCR (qPCR), and real-time qPCR with amoebic co-culture. Using the conventional culture method, Legionella pneumophila was detected in 11 samples (11/68, 16.2%). Contrary to our expectation, the culture method with the amoebic co-culture technique did not increase the detection rate of Legionella (4/68, 5.9%). In contrast, a combination of the amoebic co-culture technique followed by qPCR successfully increased the detection rate (57/68, 83.8%) compared with real-time qPCR alone (46/68, 67.6%). Using real-time qPCR after culture with amoebic co-culture, more than 10-fold higher bacterial numbers were observed in 30 samples (30/68, 44.1%) compared with the same samples without co-culture. On the other hand, higher bacterial numbers were not observed after propagation by amoebae in 32 samples (32/68, 47.1%). Legionella was not detected in the remaining six samples (6/68, 8.8%), irrespective of the method. These results suggest that application of the amoebic co-culture technique prior to real-time qPCR may be useful for the sensitive detection of Legionella from bath water samples. Furthermore, a combination of amoebic co-culture and real-time qPCR might be useful to detect viable and virulent Legionella because their ability to invade and multiply within free-living amoebae is considered to correlate with their pathogenicity for humans. This is the first report evaluating the efficacy of the amoebic co-culture technique for detecting Legionella in bath water samples.
Edagawa, Akiko; Kimura, Akio; Kawabuchi-Kurata, Takako; Adachi, Shinichi; Furuhata, Katsunori; Miyamoto, Hiroshi
2015-01-01
We investigated Legionella contamination in bath water samples, collected from 68 bathing facilities in Japan, by culture, culture with amoebic co-culture, real-time quantitative PCR (qPCR), and real-time qPCR with amoebic co-culture. Using the conventional culture method, Legionella pneumophila was detected in 11 samples (11/68, 16.2%). Contrary to our expectation, the culture method with the amoebic co-culture technique did not increase the detection rate of Legionella (4/68, 5.9%). In contrast, a combination of the amoebic co-culture technique followed by qPCR successfully increased the detection rate (57/68, 83.8%) compared with real-time qPCR alone (46/68, 67.6%). Using real-time qPCR after culture with amoebic co-culture, more than 10-fold higher bacterial numbers were observed in 30 samples (30/68, 44.1%) compared with the same samples without co-culture. On the other hand, higher bacterial numbers were not observed after propagation by amoebae in 32 samples (32/68, 47.1%). Legionella was not detected in the remaining six samples (6/68, 8.8%), irrespective of the method. These results suggest that application of the amoebic co-culture technique prior to real-time qPCR may be useful for the sensitive detection of Legionella from bath water samples. Furthermore, a combination of amoebic co-culture and real-time qPCR might be useful to detect viable and virulent Legionella because their ability to invade and multiply within free-living amoebae is considered to correlate with their pathogenicity for humans. This is the first report evaluating the efficacy of the amoebic co-culture technique for detecting Legionella in bath water samples. PMID:26492259
An operational method for the real-time monitoring of E. coli numbers in bathing waters.
Lebaron, Philippe; Henry, A; Lepeuple, A-S; Pena, G; Servais, P
2005-06-01
The aim of this study was to investigate the potential application of the beta-d-glucuronidase (GLUase) activity measurement for the routine detection and quantification of E. coli in marine bathing waters. GLUase activity was measured as the rate of hydrolysis of 4-methylumbelliferyl-beta-d-glucuronide. Culturable E. coli were quantified by the most probable number (MPN) microplate method. Both methods were applied to a large set of seawater samples. Significant correlation was found between the log of GLUase activity and the log of culturable E. coli. The mean coefficient of variation (CV) of the GLUase activity was less than 15% at concentrations around the current standards of International regulations whereas the CV of the microplate method was around 30%. When samples were stored at 4 degrees C and 20 degrees C, the mean CV of the GLUase activity remained below 15% up to 6 hours after sample collection whereas the range of variation of the microplate method varied between 10 and 50%. We concluded that the GLUase activity is an operational, reproducible, simple, very rapid and low cost method for the real-time enumeration of E. coli in bathing waters and should be preferred to the microplate method. The GLUase activity method should be routinely applied to the rapid enumeration of E. coli in recreational waters and recommendations for its application were suggested to water quality managers.
[Water fungi occurence in the River Supraśl-bath Jurowce near Białystok].
Kiziewicz, Bozena; Kozłowska, Mariola; Godlewska, Anna; Muszyńvska, Elzbieta; Mazalska, Bozenna
2004-01-01
Studies on the occurrence of aquatic fungi in the bathing sites of the Supraśl River in Jurowce village were collected in years 2000-2003. Hydrochemical analysis was performed using standard methods. Bait method was used to isolate the fungi. In the Supraśl River at Jurowce village 36 fungi species were identified, among them fish pathogens Achlya orion, Aphanomyces laevis, Dictyuchus monosporus, Saprolegnia ferax, Saprolegnia monoica, S. parasitica, human pathogens Aspergillus flavus, Candida albicans, Lagenidium humanum, Penicillium mycetomagenum, Rhizophydium keratinophilum and Trichosporon cutaneum, phytopathogens Achlya racemosa, Phytophthora gonapodoides, Pythium butleri, P. myriotylum and P. debaryanum. Physicochemical parameters of waters in Supraśl River-bathing sites had no important effect on the occurrence of fungi.
Method for recovering light hydrocarbons from coal agglomerates
Huettenhain, Horst; Benz, August D.; Getsoian, John
1991-01-01
A method and apparatus for removing light hydrocarbons, such as heptane, from coal agglomerates includes an enclosed chamber having a substantially horizontal perforate surface therein. The coal agglomerates are introduced into a water bath within the chamber. The agglomerates are advanced over the surface while steam is substantially continuously introduced through the surface into the water bath. Steam heats the water and causes volatilization of the light hydrocarbons, which may be collected from the overhead of the chamber. The resulting agglomerates may be collected at the opposite end from the surface and subjected to final draining processes prior to transportation or use.
Kanatani, Jun-Ichi; Isobe, Junko; Norimoto, Shiho; Kimata, Keiko; Mitsui, Chieko; Amemura-Maekawa, Junko; Kura, Fumiaki; Sata, Tetsutaro; Watahiki, Masanori
2017-05-01
We investigated the prevalence of Legionella spp. isolated from shower water in public bath facilities in Toyama Prefecture, Japan. In addition, we analyzed the genetic diversity among Legionella pneumophila isolates from shower water as well as the genetic relationship between isolates from shower water and from stock strains previously analyzed from sputum specimens. The isolates were characterized using serogrouping, 16S rRNA gene sequencing, and sequence-based typing. Legionella spp. were isolated from 31/91 (34.1%) samples derived from 17/37 (45.9%) bath facilities. Isolates from shower water and bath water in each public bath facility were serologically or genetically different, indicating that we need to isolate several L. pneumophila colonies from both bath and shower water to identify public bath facilities as sources of legionellosis. The 61 L. pneumophila isolates from shower water were classified into 39 sequence types (STs) (index of discrimination = 0.974), including 19 new STs. Among the 39 STs, 12 STs match clinical isolates in the European Working Group for Legionella Infections database. Notably, ST505 L. pneumophila SG 1, a strain frequently isolated from patients with legionellosis and from bath water in this area, was isolated from shower water. Pathogenic L. pneumophila strains including ST505 strain were widely distributed in shower water in public bath facilities, with genetic diversity showing several different origins. This study highlights the need to isolate several L. pneumophila colonies from both bath water and shower water to identify public bath facilities as infection sources in legionellosis cases. Copyright © 2017 Japanese Society of Chemotherapy and The Japanese Association for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.
Diwan, Vishal; Purohit, Manju; Chandran, Salesh; Parashar, Vivek; Shah, Harshada; Mahadik, Vijay K.; Stålsby Lundborg, Cecilia; Tamhankar, Ashok J.
2017-01-01
Background: Antibiotic resistance (ABR) is one of the major health emergencies for global society. Little is known about the ABR of environmental bacteria and therefore it is important to understand ABR reservoirs in the environment and their potential impact on health. Method/Design: Quantitative and qualitative data will be collected during a 3-year follow-up study of a river associated with religious mass-bathing in Central India. Surface-water and sediment samples will be collected from seven locations at regular intervals for 3 years during religious mass-bathing and in absence of it to monitor water-quality, antibiotic residues, resistant bacteria, antibiotic resistance genes and metals. Approval has been obtained from the Ethics Committee of R.D. Gardi Medical College, Ujjain, India (No. 2013/07/17-311). Results: The results will address the issue of antibiotic residues and antibiotic resistance with a focus on a river environment in India within a typical socio-behavioural context of religious mass-bathing. It will enhance our understanding about the relationship between antibiotic residue levels, water-quality, heavy metals and antibiotic resistance patterns in Escherichia coli isolated from river-water and sediment, and seasonal differences that are associated with religious mass-bathing. We will also document, identify and clarify the genetic differences/similarities relating to phenotypic antibiotic resistance in bacteria in rivers during religious mass-bathing or during periods when there is no mass-bathing. PMID:28555050
NASA Astrophysics Data System (ADS)
Aziz, Tengku Norazman Tengku Abd; Rosli, Aimi Bazilah; Yusoff, Marmeezee Mohd; Herman, Sukreen Hana; Zulkifli, Zurita
2018-05-01
This paper demonstrates the transfer of graphene at low temperature using water bath. Graphene in water solution (highly opaque) was transferred onto Platinum/Glass (Pt/Glass) substrate and the technique involves no additional chemicals. We obtained high transparency and large area of graphene film that is free of contaminants. The transferred graphene is characterized using FESEM, Raman spectroscopy and I-V measurements. This transfer method enables us to transfer graphene onto ZnO thin film for memristive devices.
Malc, Ewa P.; Jayakody, Chatura N.; Tsuruta, James K.; Mieczkowski, Piotr A.; Janzen, William P.; Dayton, Paul A.
2015-01-01
A perfluorocarbon nanodroplet formulation is shown to be an effective cavitation enhancement agent, enabling rapid and consistent fragmentation of genomic DNA in a standard ultrasonic water bath. This nanodroplet-enhanced method produces genomic DNA libraries and next-generation sequencing results indistinguishable from DNA samples fragmented in dedicated commercial acoustic sonication equipment, and with higher throughput. This technique thus enables widespread access to fast bench-top genomic DNA fragmentation. PMID:26186461
López, Iago; Alvarez, César; Gil, José L; Revilla, José A
2012-11-30
Data on the 95th and 90th percentiles of bacteriological quality indicators are used to classify bathing waters in Europe, according to the requirements of Directive 2006/7/EC. However, percentile values and consequently, classification of bathing waters depend both on sampling effort and sample-size, which may undermine an appropriate assessment of bathing water classification. To analyse the influence of sampling effort and sample size on water classification, a bootstrap approach was applied to 55 bacteriological quality datasets of several beaches in the Balearic Islands (Spain). Our results show that the probability of failing the regulatory standards of the Directive is high when sample size is low, due to a higher variability in percentile values. In this way, 49% of the bathing waters reaching an "Excellent" classification (95th percentile of Escherichia coli under 250 cfu/100 ml) can fail the "Excellent" regulatory standard due to sampling strategy, when 23 samples per season are considered. This percentage increases to 81% when 4 samples per season are considered. "Good" regulatory standards can also be failed in bathing waters with an "Excellent" classification as a result of these sampling strategies. The variability in percentile values may affect bathing water classification and is critical for the appropriate design and implementation of bathing water Quality Monitoring and Assessment Programs. Hence, variability of percentile values should be taken into account by authorities if an adequate management of these areas is to be achieved. Copyright © 2012 Elsevier Ltd. All rights reserved.
Amemura-Maekawa, Junko; Kura, Fumiaki; Chang, Bin; Suzuki-Hashimoto, Atsuko; Ichinose, Masayuki; Endo, Takuro; Watanabe, Haruo
2008-09-01
To investigate the genetic difference of Legionella pneumophila in human-made environments, we collected isolates of L. pneumophila from bath water (n = 167) and cooling tower water (n = 128) primarily in the Kanto region in 2001 and 2005. The environmental isolates were serogrouped and sequenced for a target region of flaA. A total of 14 types of flaA genotypes were found: 10 from cooling tower water and nine from bath water. The flaA genotypes of isolates from cooling tower water were quite different from those of bath water.
Kobayashi, Michiko; Oana, Kozue; Kawakami, Yoshiyuki
2014-01-01
Bath water samples were collected from 116 hot springs, 197 public bathhouses, and 38 24-hour home baths in Nagano Prefecture, Japan, during the period of April 2009 to November 2011, for determining the presence and extent of contamination with Legionella and nontuberculous mycobacteria. Cultures positive for Legionella were observed in 123 of the 3,314 bath water samples examined. The distribution and abundance of Legionella and/or combined contamination with Legionella and nontuberculous mycobacteria were investigated to clarify the contamination levels. The abundance of Legionella was demonstrated to correlate considerably with the levels of combined contamination with Legionella and nontuberculous mycobacteria. Legionella spp. were obtained from 61% of the water samples from 24-hour home baths, but only from 3% of the samples from public bathhouses and hot springs. This is despite the fact that a few outbreaks of Legionnaires' disease in Nagano Prefecture as well as other regions of Japan have been traced to bath water contamination. The comparatively higher rate of contamination of the 24-hour home baths is a matter of concern. It is therefore advisable to routinely implement good maintenance of the water basins, particularly of the 24-hour home baths.
Evidence from various sources around the world indicate that there is a relationship between gastroenteritis in swimmers and the quality of the bathing water as measured with bacterial indicators of fecal contamination. Current EPA guidelines recommend the use of cultural method...
RAPID METHODS FOR MEASURING INDICATOR BACTERIA IN BATHING BEACH WATERS
The current methods for measuring the quality of recreational waters were developed in the 1970's and were recommended to the States by EPA in 1986. These methods detect and quantify Escherichia coli and enterococci, two bacteria that are consistently associated with fecal wast...
RAPID, PCR-BASED METHODS FOR MEASURING THE QUALITY OF BATHING BEACH WATERS
The current methods for measuring the quality of recreational waters were developed in the 1970's and were recommended to the States by EPA in 1986. These methods detect and quantify Escherichia coli and enterococci, two bacteria that are consistently associated with fecal wast...
Kälsch, Julia; Pott, Leona L; Takeda, Atsushi; Kumamoto, Hideo; Möllmann, Dorothe; Canbay, Ali; Sitek, Barbara; Baba, Hideo A
2017-04-01
Beneficial effects of balneotherapy using naturally occurring carbonated water (CO 2 enriched) have been known since the Middle Ages. Although this therapy is clinically applied for peripheral artery disease and skin disorder, the underlying mechanisms are not fully elucidated.Under controlled conditions, rats were bathed in either CO 2 -enriched water (CO 2 content 1200 mg/L) or tap water, both at 37 °C, for 10 min daily over 4 weeks. Proliferation activity was assessed by Ki67 immunohistochemistry of the epidermis of the abdomen. The capillary density was assessed by immunodetection of isolectin-positive cells. Using cryo-fixed abdominal skin epidermis, follicle cells and stroma tissue containing capillaries were separately isolated by means of laser microdissection and subjected to proteomic analysis using label-free technique. Differentially expressed proteins were validated by immunohistochemistry.Proliferation activity of keratinocytes was not significantly different in the epidermis after bathing in CO 2 -enriched water, and also, capillary density did not change. Proteomic analysis revealed up to 36 significantly regulated proteins in the analyzed tissue. Based on the best expression profiles, ten proteins were selected for immunohistochemical validation. Only one protein, far upstream element binding protein 2 (FUBP2), was similarly downregulated in the epidermis after bathing in CO 2 -enriched water with both techniques. Low FUBP2 expression was associated with low c-Myc immune-expression in keratinocytes.Long-term bathing in CO 2 -enriched water showed a cellular protein response of epithelial cells in the epidermis which was detectable by two different methods. However, differences in proliferation activity or capillary density were not detected in the normal skin.
Yoon, Kyung Su; Huang, Xue Zhu; Yoon, Yang Suk; Kim, Soo-Ki; Song, Soon Bong; Chang, Byung Soo; Kim, Dong Heui; Lee, Kyu Jae
2011-01-01
Electrolyzed reduced water (ERW), functional water, has various beneficial effects via antioxidant mechanism in vivo and in vitro. However there is no study about beneficial effects of ERW bathing. This study aimed to determine the effect of ERW bathing on the UVB-induced skin injury in hairless mice. For this purpose, mice were irradiated with UVB to cause skin injury, followed by individually taken a bath in ERW (ERW-bathing) and tap water (TW-bathing) for 21 d. We examined cytokines profile in acute period, and histological and ultrastructural observation of skin in chronic period. We found that UVB-mediated skin injury of ERW-bathing group was significantly low compared to TW control group in the early stage of experiment. Consistently, epidermal thickening as well as the number of dermal mast cell was significantly lowered in ERW-bathing group. Defection of corneocytes under the scanning electron microscope was less observed in ERW-bathing group than in TW-bathing group. Further, the level of interleukin (IL)-1β, tumor necrosis factor (TNF)-α and IL-12p70 in ERW group decreased whereas those of IL-10 increased. Collectively, our data indicate that ERW-bathing significantly reduces UVB-induced skin damage through influencing pro-/anti-inflammatory cytokine balance in hairless mice. This suggests that ERW-bathing has a positive effect on acute UVB-mediated skin disorders. This is the first report on bathing effects of ERW in UVB-induced skin injury.
Characterization of Polysulfone Membranes Prepared with Thermally Induced Phase Separation Technique
NASA Astrophysics Data System (ADS)
Tiron, L. G.; Pintilie, Ș C.; Vlad, M.; Birsan, I. G.; Baltă, Ș
2017-06-01
Abstract Membrane technology is one of the most used water treatment technology because of its high removal efficiency and cost effectiveness. Preparation techniques for polymer membranes show an important aspect of membrane properties. Generally, polysulfone (PSf) and polyethersulfone (PES) are used for the preparation of ultrafiltration (UF) membranes. Polysulfone (PSf) membranes have been widely used for separation and purification of different solutions because of their excellent chemical and thermal stability. Polymeric membranes were obtained by phase inversion method. The polymer solution introduced in the nonsolvent bath (distilled water) initiate the evaporation of the solvent from the solution, this phenomenon has a strong influence on the transport properties. The effect of the coagulation bath temperature on the membrane properties is of interest for this study. Membranes are characterized by pure water flux, permeability, porosity and retention of methylene blue. The low temperature of coagulation bath improve the membrane’s rejection and its influence was most notable.
Nerandzic, Michelle M.; Rackaityte, Elze; Jury, Lucy A.; Eckart, Kevin; Donskey, Curtis J.
2013-01-01
Background Removing spores of Clostridium difficile and Bacillus anthracis from skin is challenging because they are resistant to commonly used antimicrobials and soap and water washing provides only modest efficacy. We hypothesized that hygiene interventions incorporating a sporicidal electrochemically generated hypochlorous acid solution (Vashe®) would reduce the burden of spores on skin. Methods Hands of volunteers were inoculated with non-toxigenic C. difficile spores or B. anthracis spore surrogates to assess the effectiveness of Vashe solution for reducing spores on skin. Reduction in spores was compared for Vashe hygiene interventions versus soap and water (control). To determine the effectiveness of Vashe solution for removal of C. difficile spores from the skin of patients with C. difficile infection (CDI), reductions in levels of spores on skin were compared for soap and water versus Vashe bed baths. Results Spore removal from hands was enhanced with Vashe soak (>2.5 log10 reduction) versus soap and water wash or soak (~2.0 log10 reduction; P <0.05) and Vashe wipes versus alcohol wipes (P <0.01). A combined approach of soap and water wash followed by soaking in Vashe removed >3.5 log10 spores from hands (P <0.01 compared to washing or soaking alone). Bed baths using soap and water (N =26 patients) did not reduce the percentage of positive skin cultures for CDI patients (64% before versus 57% after bathing; P =0.5), whereas bathing with Vashe solution (N =21 patients) significantly reduced skin contamination (54% before versus 8% after bathing; P =0.0001). Vashe was well-tolerated with no evidence of adverse effects on skin. Conclusions Vashe was safe and effective for reducing the burden of B. anthracis surrogates and C. difficile spores on hands. Bed baths with Vashe were effective for reducing C. difficile on skin. These findings suggest a novel strategy to reduce the burden of spores on skin. PMID:23844234
Bedri, Zeinab; O'Sullivan, John J; Deering, Louise A; Demeter, Katalin; Masterson, Bartholomew; Meijer, Wim G; O'Hare, Gregory
2015-02-15
A three-dimensional model is used to assess the bathing water quality of Bray and Killiney bathing sites in Ireland following changes to the sewage management system. The model, firstly calibrated to hydrodynamic and water quality data from the period prior to the upgrade of the Wastewater Treatment Works (WwTW), was then used to simulate Escherichia coli (E. coli) distributions for discharge scenarios of the periods prior to and following the upgrade of the WwTW under dry and wet weather conditions. E. coli distributions under dry weather conditions demonstrate that the upgrade in the WwTW has remarkably improved the bathing water quality to a Blue Flag status. The new discharge strategy is expected to drastically reduce the rainfall-related incidents in which environmental limits of the Bathing Water Directive are breached. However, exceedances to these limits may still occur under wet weather conditions at Bray bathing site due to storm overflows that may still be discharged through two sea outfalls offshore of Bray bathing site. Copyright © 2014 Elsevier Ltd. All rights reserved.
The oil-dispersion bath in anthroposophic medicine – an integrative review
Büssing, Arndt; Cysarz, Dirk; Edelhäuser, Friedrich; Bornhöft, Gudrun; Matthiessen, Peter F; Ostermann, Thomas
2008-01-01
Background Anthroposophic medicine offers a variety of treatments, among others the oil-dispersion bath, developed in the 1930s by Werner Junge. Based on the phenomenon that oil and water do not mix and on recommendations of Rudolf Steiner, Junge developed a vortex mechanism which churns water and essential oils into a fine mist. The oil-covered droplets empty into a tub, where the patient immerses for 15–30 minutes. We review the current literature on oil-dispersion baths. Methods The following databases were searched: Medline, Pubmed, Embase, AMED and CAMbase. The search terms were 'oil-dispersion bath' and 'oil bath', and their translations in German and French. An Internet search was also performed using Google Scholar, adding the search terms 'study' and 'case report' to the search terms above. Finally, we asked several experts for gray literature not listed in the above-mentioned databases. We included only articles which met the criterion of a clinical study or case report, and excluded theoretical contributions. Results Among several articles found in books, journals and other publications, we identified 1 prospective clinical study, 3 experimental studies (enrolling healthy individuals), 5 case reports, and 3 field-reports. In almost all cases, the studies described beneficial effects – although the methodological quality of most studies was weak. Main indications were internal/metabolic diseases and psychiatric/neurological disorders. Conclusion Beyond the obvious beneficial effects of warm bathes on the subjective well-being, it remains to be clarified what the unique contribution of the distinct essential oils dispersed in the water can be. There is a lack of clinical studies exploring the efficacy of oil-dispersion baths. Such studies are recommended for the future. PMID:19055811
Changes of minimal erythema dose after water and salt water baths.
Gambichler, T; Schröpl, F
1998-01-01
Knowledge about the influence of salt water baths on UV irradiation, especially balneophototherapy, is incomplete. The aim of this study was to investigate the influence of various concentrated salt solutions on the minimal erythema dose (MED). We determined the MEDdry (UVB) in 24 healthy, previously UV unexposed subjects on the inner forearm. Subjects were divided randomly into two groups of 12. Subsequently, the MEDwet was assessed on each forearm after 30 min tap water or 5% salt water bath (group A), respectively, or after 30 min 10% or 20% salt water bath (group B), respectively. Compared with the MEDdry, a significantly decreased MEDwet, was observed after all exposures (group A==>F = 18.94; P < 0.001; group B==>F = 11.73; P < 0.006). A maximal relative decrease in MEDdry of about 51.4% was observed after the 10% salt water bath. The 5% salt solution caused a modest relative decrease in MEDwet of 23.4%. We observed a markedly increased photosensitivity to UVB after all exposures, without a linear correlation between the MED and the salt water concentration. A determination of MED during balneophototherapy should be carried out after bathing in order to reduce the cumulative UV dose and to prevent acute photodamage.
How does washing without water perform compared to the traditional bed bath: a systematic review.
Groven, Fabian M V; Zwakhalen, Sandra M G; Odekerken-Schröder, Gaby; Joosten, Erik J T; Hamers, Jan P H
2017-01-25
For immobile patients, a body wash in bed is sometimes the only bathing option. Traditionally, the bed bath is performed with water and soap. However, alternatives are increasingly used in health care. Washing without water is one such alternative that has been claimed to offer several advantages, such as improved hygiene and skin condition. This systematic review aims to provide a comprehensive overview of the evidence on outcomes of the washing without water concept compared to the traditional bed bath. Controlled trials about washing without water outcomes published after 1994 were collected by means of a systematic literature search in CINAHL, Embase, MEDLINE, and PUBMED at the 25th of February, 2016. Additionally, references and citations were searched and experts contacted. Studies were eligible if (1) the study designs included outcomes of washing without water products developed for the full body wash compared to the traditional bed bath, and (2) they were controlled trials. Two researchers independently used a standardized quality checklist to assess the methodological quality of the eligible studies. Finally, outcomes were categorized in (1) physiological outcomes related to hygiene and skin condition, (2) stakeholder-related outcomes, and (3) organizational outcomes in the data synthesis. Out of 33 potentially relevant articles subjected to full text screening, six studies met the eligibility criteria. Only two studies (of the same research group) were considered of high quality. The results of these high quality studies show that washing without water performed better than the traditional bed bath regarding skin abnormalities and bathing completeness. No differences between washing without water and the traditional bed bath were found for outcomes related to significant skin lesions, resistance during bathing and costs in the studies of high quality. There is limited moderate to high quality evidence that washing without water is not inferior to the traditional bed bath. Future research on washing without water is needed and should pay special attention to costs, hygiene, and to stakeholder-related outcomes, such as experiences and value perceptions of patients, nursing staff and family.
The original EPA recreational water health studies, initiated in 1972 and completed in 1982, were designed to determine the relationship between swimming-associated gastroenteritis and the quality of the bathing water. The water quality was measured using multiple microbial indi...
Effect of balneotherapy on the antioxidant system--a controlled pilot study.
Bender, Tamás; Bariska, János; Vághy, Richárd; Gomez, Roberto; Imre Kovács
2007-01-01
Balneotherapy is among the most widely used modalities of physical therapy in countries rich in mineral waters. This trial was intended to ascertain whether balneotherapy (i.e., therapeutic bath in mineral water) has any influence on the antioxidant system and whether there are any differences compared to bathing in tap water. The ten subjects in Group I bathed in alkaline thermal water, Group II used alkaline, chlorine-containing mineral water, whereas Group III bathed in tap water. Catalase, superoxide dismutase, malondialdehyde protein and glutathione peroxidase levels were measured at baseline and after concluding the course of balneotherapy. Balneotherapy with either of the two mineral waters reduced the activity of all four enzymes studied. Using tap water, however, had no influence on either catalase or superoxide dismutase activity after one session or glutathione peroxidase levels after a course of ten balneotherapy treatments. Thermal water may have a beneficial effect on the formation of free radicals. The therapeutic efficacy of mineral vs. tap water is different, although bathing in hot water itself reduces enzyme activity.
Code of Federal Regulations, 2011 CFR
2011-07-01
... and emergency operation of safety showers and eye washes; storm water; Department of Transportation (DOT) aerosol leak test bath water from non-continuous overflow baths (batch baths) where no cans have burst from the time of the last water change-out; and on-site laboratories from cleaning analytical...
Code of Federal Regulations, 2010 CFR
2010-07-01
... and emergency operation of safety showers and eye washes; storm water; Department of Transportation (DOT) aerosol leak test bath water from non-continuous overflow baths (batch baths) where no cans have burst from the time of the last water change-out; and on-site laboratories from cleaning analytical...
Method of forming oxide coatings. [for solar collector heating panels
NASA Technical Reports Server (NTRS)
Mcdonald, G. E. (Inventor)
1983-01-01
This invention is concerned with an improved plating process for covering a substrate with a black metal oxide film. The invention is particularly directed to making a heating panel for a solar collector. A compound is electrodeposited from an aqueous solution containing cobalt metal salts onto a metal substrate. This compound is converted during plating into a black, highly absorbing oxide coating which contains hydrated oxides. This is achieved by the inclusion of an oxidizing agent in the plating bath. The inclusion of an oxidizing agent in the plating bath is contrary to standard electroplating practice. The hydrated oxides are converted to oxides by treatment in a hot bath, such as boiling water. An oxidizing agent may be added to the hot liquid treating bath.
Lavender, Tina; Bedwell, Carol; Roberts, Stephen A; Hart, Anna; Turner, Mark A; Carter, Lesley-Anne; Cork, Michael J
2013-01-01
Objectives To examine the hypothesis that the use of a wash product formulated for newborn (<1 month of age) bathing is not inferior (no worse) to bathing with water only. Design Assessor-blinded, randomized, controlled, noninferiority trial. Setting A teaching hospital in the Northwest of England and in participants’ homes. Participants Three-hundred-and-seven healthy, term infants recruited within 48 hours of birth. Method We compared bathing with a wash product (n = 159) to bathing with water alone (n = 148). The primary outcome was transepidermal water loss (TEWL) at 14 days postbirth; the predefined difference deemed to be unimportant was 1.2. Secondary outcomes comprised changes in stratum corneum hydration, skin surface pH, clinical observations of the skin, and maternal views. Results Complete TEWL data were obtained for 242 (78.8%) infants. Wash was noninferior to water alone in terms of TEWL (intention-to-treat analysis: 95% confidence interval [CI] for difference [wash–water, adjusted for family history of eczema, neonate state, and baseline] −1.24, 1.07; per protocol analysis: 95% CI −1.42, 1.09). No significant differences were found in secondary outcomes. Conclusion We were unable to detect any differences between the newborn wash product and water. These findings provide reassurance to parents who choose to use the test newborn wash product or other technically equivalent cleansers and provide the evidence for health care professionals to support parental choice. PMID:23421327
Code of Federal Regulations, 2013 CFR
2013-07-01
... equipment; the testing and emergency operation of safety showers and eye washes; storm water; Department of Transportation (DOT) aerosol leak test bath water from non-continuous overflow baths (batch baths) where no cans have burst from the time of the last water change-out; and on-site laboratories from cleaning...
Code of Federal Regulations, 2012 CFR
2012-07-01
... equipment; the testing and emergency operation of safety showers and eye washes; storm water; Department of Transportation (DOT) aerosol leak test bath water from non-continuous overflow baths (batch baths) where no cans have burst from the time of the last water change-out; and on-site laboratories from cleaning...
Code of Federal Regulations, 2014 CFR
2014-07-01
... equipment; the testing and emergency operation of safety showers and eye washes; storm water; Department of Transportation (DOT) aerosol leak test bath water from non-continuous overflow baths (batch baths) where no cans have burst from the time of the last water change-out; and on-site laboratories from cleaning...
THE NEED FOR SPEED-RAPID METHODOLOGIES TO DETERMINE BATHING BEACH WATER QUALITY
Current methods for determining fecal contamination of recreational waters rely on the culture of bacterial indicators and require at least 24 hours to determine whether the water is unsafe for use. By the time monitoring results are available, exposures have already occurred. N...
Improving efficiency, reducing infection, and enhancing experience.
Massa, Judith
For health professionals to make an informed choice and tailor each bed bath to the individual needs of the patient, they must firstly understand the different bed bath options available, their impact on skin integrity, and any associated risks they may pose to the patient in terms of cross-infection. Only with this knowledge can health professionals determine the appropriate form and frequency of the bed bath. Specialist wipes offer significant improvements in skin care and a reduced risk of cross-infection, compared with the traditional soap and water bed bath. Use of these wipes also improves the efficiency of the process, which links to the Productive Ward Initiative and results in clinical staff (i.e. nursing staff, healthcare assistants) having more time available to undertake additional patient care activities. This product focus highlights the benefits of moving to a wipe-based bed bath method, and the significant efficiency savings that can be realized as a result.
Zbikowska, Elżbieta; Walczak, Maciej; Krawiec, Arkadiusz
2013-01-01
The present study was aimed at investigating the coexistence and interactions between free living amoebae of Naegleria and Hartmannella genera and pathogenic Legionella pneumophila bacteria in thermal saline baths used in balneotherapy in central Poland. Water samples were collected from November 2010 to May 2011 at intervals longer than 1 month. The microorganisms were detected with the use of a very sensitive fluorescence in situ hybridisation method. In addition, the morphology of the amoebae was studied. Despite relatively high salinity level, ranging from 1.5 to 5.0 %, L. pneumophila were found in all investigated baths, although their number never exceeded 10(6) cells dm(-3). Hartmannella were not detected, while Naegleria fowleri were found in one bath. The observation that N. fowleri and L. pneumophila may coexist in thermal saline baths is the first observation emphasising potential threat from these microorganisms in balneotherapy.
Immunocytochemistry associated with oral exfoliative cytology: methodological analysis..
da Silva, Alessandra Dutra; Lima, Celina Faig; Maraschin, Bruna Jalfim; Laureano, Natália Koerich; Daroit, Natália Batista; Brochier, Fernanda; Sant'Ana Filho, Manoel; Visioli, Fernanda; Rados, Pantelis Varvaki
2015-04-01
To evaluate different immunocytochemical protocol variations to find the most effective protocol for the analysis of involucrin, epidermal growth factor receptor (EGFR), and E-cadherin antibodies. Exfoliative cytology is a noninvasive method used to monitor and screen for early changes in the oral mucosa of patients exposed to carcinogens such as tobacco and alcohol. It has been postulated that its association with immunocytochemistry may improve the effectiveness of the screening process. Four graduate students from Porto Alegre in southern Brazil had oral smears collected from the border of the tongue using a cytobrush. The following variables were analyzed: cell membrane permeability, antigen retrieval method (microwave oven or water bath), antibody incubation time (overnight or 1 hour), detection system used (Envision or LSAB), and chromogen incubation time (10 seconds or 5 minutes). Best results were obtained with the following combinations: (1) for involucrin: water bath, 1-hour incubation for primary antibody, Envision, and chromogen incubation for 10 seconds; (2)for EGFR: microwave, overnight incubation, LSAB, and chromogen incubation for 5 minutes; and (3) for E-cadherin: water bath, over-night incubation, Envision, and chromogen incubation for 5 minutes. Our findings suggest that each antibody requires a specific immunocytochemical protocol to guarantee optimal results with oral smears.
Poly/vinyl alcohol/ membranes for reverse osmosis
NASA Technical Reports Server (NTRS)
Katz, M. G.; Wydeven, T., Jr.
1981-01-01
A description is presented of the results of studies of the water and salt transport properties of PVA membranes, taking into account radiation crosslinked PVA membranes, diffusive salt permeability through PVA membranes, and heat treated PVA membranes. The experimental findings support an occurrence of independent water, and salt permeation processes. It is suggested that the salt permeation is governed by a solution-diffusion transport mechanism. The preparation of thin skinned, asymmetric PVA membranes is also discussed. The employed method has a certain similarity to the classical phase inversion method, which is widely applied in the casting of asymmetric reverse osmosis membranes. Instead of using a gelling bath composed of a nonsolvent for the membrane material and miscible with the solvent from which the membrane is cast, a 'complexing' bath is used, which is a solution of a complexing agent in water.
Method for cleaning bomb-reduced uranium derbies
Banker, John G.; Wigginton, Hubert L.; Beck, David E.; Holcombe, Cressie E.
1981-01-01
The concentration of carbon in uranium metal ingots induction cast from derbies prepared by the bomb-reduction of uranium tetrafluoride in the presence of magnesium is effectively reduced to less than 100 ppm by removing residual magnesium fluoride from the surface of the derbies prior to casting. This magnesium fluoride is removed from the derbies by immersing them in an alkali metal salt bath which reacts with and decomposes the magnesium fluoride. A water quenching operation followed by a warm nitric acid bath and a water rinse removes the residual salt and reaction products from the derbies.
Method for cleaning bomb-reduced uranium derbies
Banker, J.G.; Wigginton, H.L.; Beck, D.E.; Holcombe, C.E.
The concentration of carbon in uranium metal ingots induction cast from derbies prepared by the bomb-reduction of uranium tetrafluoride in the presence of magnesium is effectively reduced to less than 100 ppM by removing residual magnesium fluoride from the surface of the derbies prior to casting. This magnesium fluoride is removed from the derbies by immersing them in an alkali metal salt bath which reacts with and decomposes the magnesium fluoride. A water quenching operation followed by a warm nitric acid bath and a water rinse removes the residual salt and reaction products from the derbies.
Vial OrganicTM-Organic Chemistry Labs for High School and Junior College
NASA Astrophysics Data System (ADS)
Russo, Thomas J.; Meszaros, Mark
1999-01-01
Vial Organic is the most economical, safe, and time-effective method of performing organic chemistry experiments. Activities are carried out in low-cost, sealed vials. Vial Organic is extremely safe because only micro quantities of reactants are used, reactants are contained in tightly sealed vials, and only water baths are used for temperature control. Vial Organic laboratory activities are easily performed within one 50-minute class period. When heat is required, a simple hot-water bath is prepared from a beaker of water and an inexpensive immersion heater. The low cost, ease of use, and relatively short time requirement will allow organic chemistry to be experienced by more students with less confusion and intimidation.
Kendrick, Denise; Stewart, Jane; Coupland, Carol; Hayes, Michael; Hopkins, Nick; McCabe, Debbie; Murphy, Robert; O'Donnell, George; Phillips, Ceri; Radford, David; Ryan, Jackie; Smith, Sherie; Groom, Lindsay; Towner, Elizabeth
2008-01-01
Background Each year in the UK 2000 children attend emergency departments and 500 are admitted to hospital following a bath water scald. The long term effects can include disability, disfigurement or psychological harm and repeated skin grafts may be required as the child grows. The costs of treating a severe scald are estimated at 250,000 GBP. Children living in the most deprived wards are at greatest risk of thermal injuries; hospital admission rates are three times that for children living in the least deprived wards. Domestic hot water, which is usually stored at around 60 degrees Celsius, can result in a second-degree burn after 3 seconds and a third-degree burn after 5 seconds. Educational strategies to encourage testing of tap water temperature and reduction of hot water thermostat settings have largely proved unsuccessful. Legislation in the USA mandating pre-setting hot water heater thermostats at 49 degrees Celsius was effective in reducing scald injuries, suggesting passive measures may have a greater impact. Thermostatic mixer valves (TMVs), recently developed for the domestic market, fitted across the hot and cold water supply pipes of the bath, allow delivery of water set at a fixed temperature from the hot bath tap. These valves therefore offer the potential to reduce scald injuries. Design/Methods A pragmatic, randomised controlled trial to assess the effectiveness of TMVs in reducing bath hot tap water temperatures in the homes of families with young children in rented social housing. Two parallel arms include an intervention group and a control group where the intervention will be deferred. The intervention will consist of fitting a TMV (set at 44 degrees Celsius) by a qualified plumber and provision of educational materials. The control arm will not receive a TMV or the educational materials for the study duration but will be offered the intervention after collection of follow-up data 12 months post randomisation. The primary outcome measure will be the bath hot tap water temperature. Fifteen families per arm are required to detect a reduction in the mean bath hot tap water temperature from 60.4 degrees Celsius (SD 9.1) in the control group to 46 degrees Celsius in the intervention group, with 90% power and a 5% significance level (2 sided). Secondary outcome measures including acceptability will require a sample size of 120 participants. Discussion Whilst TMVs have the potential to reduce scald injuries, to date there have been no randomised controlled trials assessing their effectiveness, acceptability and cost effectiveness. Trial Registration ISRCTN21179067 PMID:18348736
Xu, Yan-Jun; Elimban, Vijayan; Dhalla, Naranjan S
2017-08-01
In this study, we investigated the effects of CO 2 water-bath therapy on blood flow and angiogenesis in the ischemic hind limb, as well as some plasma angiogenic factors in peripheral ischemic model. The hind limb ischemia was induced by occluding the femoral artery for 2 weeks in rats and treated with or without CO 2 water-bath therapy at 37 °C for 4 weeks (20 min treatment every day for 5 days per week). The peak blood flow and minimal and mean blood flow in the ischemic skeletal muscle were markedly increased by the CO 2 water-bath therapy. This increase in blood flow was associated with development of angiogenesis in the muscle, as well as reduction in the ischemia-induced increase in plasma malondialdehyde levels. Although plasma vascular endothelial growth factor and nitric oxide levels were increased in animals with peripheral ischemia, the changes in these biomarkers were not affected by CO 2 water-bath therapy. These results suggest that augmentation of blood flow in the ischemic hind limb by CO 2 water-bath therapy may be due to the development of angiogenesis and reduction in oxidative stress.
WATER QUALITY AND SWIMMING-ASSOCIATED HEALTH EFFECTS
Evidence from various sources around the world indicate that there is a relationship between gastroenteritis in swimmers and the quality of the bathing water as measured with bacterial indicators of fecal contamination. Current EPA guidelines recommend the use of cultural method...
Tissue floaters and contaminants in the histology laboratory.
Platt, Eric; Sommer, Paul; McDonald, Linda; Bennett, Ana; Hunt, Jennifer
2009-06-01
Anatomic pathology diagnosis is often based on morphologic features. In recent years, an appropriate increased attention to patient safety has led to an emphasis on improving maintenance of patient identity. Decreasing or eliminating cross-contamination from one specimen to another is an example of a patient identity issue for which process improvement can be initiated. To quantify the presence of cross-contamination from histology water baths and the slide stainers. We assessed for the presence of contaminants in water baths at cutting stations and in linear stainer stain baths. We assessed the potential for tissue discohesion and carryover in tissue samples and we assessed the potential for carryover onto blank slides sent through the stainer. In the 13 water baths examined (totalling 195 L of water), only one fragment of tissue was identified. The stain baths, however, contained abundant tissue contaminants, ranging in size from 2 to 3 cells to hundreds of cells. The first sets of xylenes and alcohols were the most heavily contaminated. Cross-contamination to blank slides occurred at a rate of 8%, with the highest frequency in the late afternoon. Cross-contamination can present a significant challenge in the histology laboratory. Although the histotechnologists' water baths are not heavily contaminated, the stainer baths do contain contaminating tissue fragments. Cross-contamination does occur onto blank slides in the experimental setting.
Simple and double emulsions via electrospray
NASA Astrophysics Data System (ADS)
Barrero, Antonio; Loscertales, Ignacio G.
2005-11-01
Generation of nanoemulsions is of great interest in medical and pharmaceutical applications; drug delivery or antiviral emulsions are typical examples. The use of electrosprays for dispersing liquids inside liquid insulator baths have been recently reported, (Barrero et al. J. Colloid Interf. Sci. 272, 104, 2004). Capsules, nanotubes and coaxial nanofibers have been obtained from electrified coaxial jets (Loscertales et al. Science 295, n. 5560, 1695, 2002; J. American Chem. Soc. 126, 5376, 2004). Here we present a method for making double emulsions (both water-oil-water and o/w/o) based on the generation of compound electrosprays inside insulator liquid baths. Basically, a conducting liquid injected throughout a capillary needle is electroatomized in cone-jet mode inside a dielectric liquid bath. A third insulating liquid is injected inside the Taylor cone to form a second meniscus. Then, a steady coaxial jet, in which the insulating liquid is coated by the conducting one, develops. A double emulsion forms as a result of the jet breaking up into compound droplets electrically charged. Experimental results carried out with glycerine and different oils in a bath of heptane are reported.
21 CFR 720.4 - Information requested about cosmetic products.
Code of Federal Regulations, 2011 CFR
2011-04-01
.... (iii) Other baby products. (2) Bath preparations. (i) Bath oils, tablets, and salts. (ii) Bubble baths. (iii) Bath capsules. (iv) Other bath preparations. (3) Eye makeup preparations. (i) Eyebrow pencil. (ii... preparations. (4) Fragrance preparations. (i) Colognes and toilet waters. (ii) Perfumes. (iii) Powders (dusting...
21 CFR 720.4 - Information requested about cosmetic products.
Code of Federal Regulations, 2010 CFR
2010-04-01
.... (iii) Other baby products. (2) Bath preparations. (i) Bath oils, tablets, and salts. (ii) Bubble baths. (iii) Bath capsules. (iv) Other bath preparations. (3) Eye makeup preparations. (i) Eyebrow pencil. (ii... preparations. (4) Fragrance preparations. (i) Colognes and toilet waters. (ii) Perfumes. (iii) Powders (dusting...
NATIONAL EPIDEMIOLOGICAL AND ENVIRONMENTAL ASSESSMENT OF RECREATIONAL WATER STUDY
Evidence from various sources around the world indicate that there is a relationship between gastroenteritis in swimmers and the quality of the bathing water as measured with bacterial indicators of fecal contamination. Current EPA guidelines recommend the use of cultural method...
The effect of sonication method on the mechanical properties of nanosilicon/epoxy composite
NASA Astrophysics Data System (ADS)
Razali, Nur Zarifah; Abidin, Mohd Hanafiah; Romli, Ahmad Zafir
2017-09-01
An experimental work had been conducted to deeply understand the science of dispersion uniformity and mechanical properties exerted with the addition of nano-powder in composite system. The epoxy with nano-silicon contained between 1-5 wt% were utilized to investigate the mechanical behavior and identify the morphology changes and fracture by using optical micrograph images (in which will be discussed in the fractography section). Sonication method was utilized in distributing nano-silicon homogenously in the matrix and two type of devices opted were horn and bath sonicator. In this study, an in-direct sonication (bath) method which having a frequency of 42 kHz was introduced to the samples by using water as a medium and a comparison had been made between bath and horn sonicator efficiency. Non-destructive testing such as density and morphology testing like Optical micrograph was done as to identify the morphology changes in micro-level as well as to confirm the uniformity of nano-silicon distribution in the viscous epoxy. Whilst the destructive testing (i.e izod impact) was used to measure toughness and strength of composite sample. Result shows that Izod impact at velocity 2.0 ms-1 are 2.1kJ/m2 (for bath sonication) and 1.5kJ/m2 (for horn sonication) at velocity of 3.5 ms-1 are 2.8 kJ/m2 (for bath sonication) and 2.0kJ/m2 (for horn sonication). It can be concluded that bath sonication method give significant increment compared to horn sonication.
Singh, Sunint; Palaskar, Jayant N.; Mittal, Sanjeev
2013-01-01
Background: Conventional heat cure poly methyl methacrylate (PMMA) is the most commonly used denture base resin despite having some short comings. Lengthy polymerization time being one of them and in order to overcome this fact microwave curing method was recommended. Unavailability of specially designed microwavable acrylic resin made it unpopular. Therefore, in this study, conventional heat cure PMMA was polymerized by microwave energy. Aim and Objectives: This study was designed to evaluate the surface porosities in PMMA cured by conventional water bath and microwave energy and compare it with microwavable acrylic resin cured by microwave energy. Materials and Methods: Wax samples were obtained by pouring molten wax into a metal mold of 25 mm × 12 mm × 3 mm dimensions. These samples were divided into three groups namely C, CM, and M. Group C denotes conventional heat cure PMMA cured by water bath method, CM denotes conventional heat cure PMMA cured by microwave energy, M denotes specially designed microwavable acrylic denture base resin cured by microwave energy. After polymerization, each sample was scanned in three pre-marked areas for surface porosities using the optical microscope. As per the literature available, this instrument is being used for the first time to measure the porosity in acrylic resin. It is a reliable method of measuring area of surface pores. Portion of the sample being scanned is displayed on the computer and with the help of software area of each pore was measured and data were analyzed. Results: Conventional heat cure PMMA samples cured by microwave energy showed maximum porosities than the samples cured by conventional water bath method and microwavable acrylic resin cured by microwave energy. Higher percentage of porosities was statistically significant, but well within the range to be clinically acceptable. Conclusion: Within the limitations of this in-vitro study, conventional heat cure PMMA can be cured by microwave energy without compromising on its property such as surface porosity. PMID:24015000
David, L M; Matos, J S
2005-01-01
Wet weather urban discharges are responsible for bathing water contamination. The proposal for a revised EU Directive concerning the quality of bathing water imposes significantly more stringent requirements for the management of bathing water quality, with particularly important repercussions on beaches subjected to short-term pollution incidents. The paper reviews the aspects from EU legislation most directly related to the problem of wet-weather discharges, placing special emphasis on the recent revision process of the Directive on bathing water quality, and evaluates the benefits of some potential solutions based on continuous modelling of a combined sewer system. Increasing the sewer system storage capacity or the STP hydraulic capacity may substantially reduce the untreated discharge volumes, but spill frequency reductions under 2 to 3 spill days per bathing season will hardly be achieved. Results show the severe strains that local rainfall patterns would place on compliance with the Commission's proposal for a revised Directive and highlight the importance of the changes introduced in the amended proposal recently approved by the Council, making it less prescriptive if adequate measures are adopted to prevent bathers' exposure to short-term pollution incidents.
Swan, Joshua T; Ashton, Carol M; Bui, Lan N; Pham, Vy P; Shirkey, Beverly A; Blackshear, Jolene E; Bersamin, Jimmy B; Pomer, Rubie May L; Johnson, Michael L; Magtoto, Audrey D; Butler, Michelle O; Tran, Shirley K; Sanchez, Leah R; Patel, Jessica G; Ochoa, Robert A; Hai, Shaikh A; Denison, Karen I; Graviss, Edward A; Wray, Nelda P
2016-10-01
To test the hypothesis that compared with daily soap and water bathing, 2% chlorhexidine gluconate bathing every other day for up to 28 days decreases the risk of hospital-acquired catheter-associated urinary tract infection, ventilator-associated pneumonia, incisional surgical site infection, and primary bloodstream infection in surgical ICU patients. This was a single-center, pragmatic, randomized trial. Patients and clinicians were aware of treatment-group assignment; investigators who determined outcomes were blinded. Twenty-four-bed surgical ICU at a quaternary academic medical center. Adults admitted to the surgical ICU from July 2012 to May 2013 with an anticipated surgical ICU stay for 48 hours or more were included. Patients were randomized to bathing with 2% chlorhexidine every other day alternating with soap and water every other day (treatment arm) or to bathing with soap and water daily (control arm). The primary endpoint was a composite outcome of catheter-associated urinary tract infection, ventilator-associated pneumonia, incisional surgical site infection, and primary bloodstream infection. Of 350 patients randomized, 24 were excluded due to prior enrollment in this trial and one withdrew consent. Therefore, 325 were analyzed (164 soap and water versus 161 chlorhexidine). Patients acquired 53 infections. Compared with soap and water bathing, chlorhexidine bathing every other day decreased the risk of acquiring infections (hazard ratio = 0.555; 95% CI, 0.309-0.997; p = 0.049). For patients bathed with soap and water versus chlorhexidine, counts of incident hospital-acquired infections were 14 versus 7 for catheter-associated urinary tract infection, 13 versus 8 for ventilator-associated pneumonia, 6 versus 3 for incisional surgical site infections, and 2 versus 0 for primary bloodstream infection; the effect was consistent across all infections. The absolute risk reduction for acquiring a hospital-acquired infection was 9.0% (95% CI, 1.5-16.4%; p = 0.019). Incidences of adverse skin occurrences were similar (18.9% soap and water vs 18.6% chlorhexidine; p = 0.95). Compared with soap and water, chlorhexidine bathing every other day decreased the risk of acquiring infections by 44.5% in surgical ICU patients.
TEMPORAL VARIABILITY OF MICROBIAL INDICATORS OF FECAL CONTAMINATION OF MARINE AND FRESHWATER BEACHES
Monitoring methods for microbial indicators of fecal contamination are an integral component for protecting the health of swimmers exposed to potentially contaminated bathing beach waters. The design of monitoring systems which will accurately characterize the quality of water is...
Matos, C; Briga-Sá, A; Bentes, I; Faria, D; Pereira, S
2017-05-15
Nowadays, water and energy consumption is intensifying every year in most of the countries. This perpetual increase will not be supportable in the long run, making urgently to manage these resources on a sustainable way. Domestic consumptions of water and electric energy usually are related and it's important to study that relation, identifying opportunities for use efficient improvement. In fact, without an understanding of water-energy relations, there are water efficiency measures that may lead to unintentional costs in the energy efficiency field. In order to take full advantage of combined effect between water and energy water management methodologies, it is necessary to collect data to ensure that the efforts are directed through the most effective paths. This paper presents a study based in the characterization, measurement and analysis of water and electricity consumption in a single family house (2months period) in order to find an interdependent relationship between consumptions at the end user level. The study was carried out on about 200 baths, divided in four different scenarios where the influence of two variables was tested: the flow reducer valve and the bath temperature. Data showed that the presence of flow reducer valve decreased electric energy consumption and water consumption, but increased the bath duration. Setting a lower temperature in water-heater, decreased electric consumption, water consumption and bath duration. Analysing the influence of the flow reducer valve and 60°C temperature simultaneously, it was concluded that it had a significant influence on electric energy consumption and on the baths duration but had no influence on water consumption. Copyright © 2017 The Author(s). Published by Elsevier B.V. All rights reserved.
Bath and Shower Diverter Notice of Intent
An often-overlooked source of wasted water, many bath and shower diverters continuously leak a small amount of water from the tub spout while they are engaged, and water is being diverted from the bathtub to the showerhead.
PROTECTING HEALTH WITH SAME DAY WATER QUALITY MONITORING RESULTS FOR BATHING BEACHES
Current US Environmental Protection Agency guidelines recommend the use of cultural methods for E. coli and enterococci to monitor beach water quality. The guidelines recommend a single sample value or a geometric mean value from at least five samples. The single sample guideli...
Machado, Cristiane; Rizzatti-Barbosa, Célia M; Gabriotti, Morgana N; Joia, Fábio A; Ribeiro, Margarete C; Sousa, Rodrigo L S
2004-07-01
The aim of this work was to evaluate the solubility of acrylic resin activated by microwave irradiation (MI) or water bath (WB), when submitted to chemical (CP) or mechanical (MP) polishing. Forty acrylic resin samples were made and processed either by water bath (74 +/- 1 degrees C, 9 h) or microwave irradiation (500 W, 3 min). After deflasking, the samples were finished with aluminum oxide sandpapers in decreasing granulations till reaching similar dimensions. The samples were divided into four groups according to the association between kind of polymerization and polishing: A (WB + CP), B (WB + MP), C (MI + CP) and D (MI + MP). Solubility test was performed for each group and percentile solubility was calculated. Data were statistically analyzed using variance analysis and Kruskal-Wallis. The average of percentile solubility (%) was obtained: A = 0.07, B = 0.02, C = 0.04, D = -0.14, however, no significant difference was found between types of polishing in the samples polymerized by water bath (A and B). When processed by microwave irradiation (C and D), there was significant difference between the applied methods of polishing, so that mechanical polishing lead to a lower solubility. Solubility is a property of acrylic resins, representing not reacted substances releasing that could promote tissular reactions in prosthesis users. The association between polymerization by microwave irradiation and mechanical polishing showed less residual substances releasing for heat-cured acrylic resins, reducing the probability of developing tissular reactions.
33 CFR 334.45 - Kennebec River, Bath Iron Works Shipyard, naval restricted area, Bath, Maine.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Shipyard, naval restricted area, Bath, Maine. 334.45 Section 334.45 Navigation and Navigable Waters CORPS... REGULATIONS § 334.45 Kennebec River, Bath Iron Works Shipyard, naval restricted area, Bath, Maine. (a) The... and other craft, except those vessels under the supervision or contract to local military or Naval...
33 CFR 334.45 - Kennebec River, Bath Iron Works Shipyard, naval restricted area, Bath, Maine.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Shipyard, naval restricted area, Bath, Maine. 334.45 Section 334.45 Navigation and Navigable Waters CORPS... REGULATIONS § 334.45 Kennebec River, Bath Iron Works Shipyard, naval restricted area, Bath, Maine. (a) The... and other craft, except those vessels under the supervision or contract to local military or Naval...
33 CFR 334.45 - Kennebec River, Bath Iron Works Shipyard, naval restricted area, Bath, Maine.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Shipyard, naval restricted area, Bath, Maine. 334.45 Section 334.45 Navigation and Navigable Waters CORPS... REGULATIONS § 334.45 Kennebec River, Bath Iron Works Shipyard, naval restricted area, Bath, Maine. (a) The... and other craft, except those vessels under the supervision or contract to local military or Naval...
33 CFR 334.45 - Kennebec River, Bath Iron Works Shipyard, naval restricted area, Bath, Maine.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Shipyard, naval restricted area, Bath, Maine. 334.45 Section 334.45 Navigation and Navigable Waters CORPS... REGULATIONS § 334.45 Kennebec River, Bath Iron Works Shipyard, naval restricted area, Bath, Maine. (a) The... and other craft, except those vessels under the supervision or contract to local military or Naval...
33 CFR 334.45 - Kennebec River, Bath Iron Works Shipyard, naval restricted area, Bath, Maine.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Shipyard, naval restricted area, Bath, Maine. 334.45 Section 334.45 Navigation and Navigable Waters CORPS... REGULATIONS § 334.45 Kennebec River, Bath Iron Works Shipyard, naval restricted area, Bath, Maine. (a) The... and other craft, except those vessels under the supervision or contract to local military or Naval...
A rapid detection method using flow cytometry to monitor the risk of Legionella in bath water.
Taguri, Toshitsugu; Oda, Yasunori; Sugiyama, Kanji; Nishikawa, Toru; Endo, Takuro; Izumiyama, Shinji; Yamazaki, Masayuki; Kura, Fumiaki
2011-07-01
Legionella species are the causative agents of human legionellosis, and bathing facilities have been identified as the sources of infection in several outbreaks in Japan. Researchers in Japan have recently reported evidence of significant associations between bacterial counts and the occurrence of Legionella in bathing facilities and in a hot tub model. A convenient and quantitative bacterial enumeration method is therefore required as an indicator of Legionella contamination or disinfection to replace existing methods such as time-consuming Legionella culture and expensive Legionella-DNA amplification. In this study, we developed a rapid detection method (RDM) to monitor the risk of Legionella using an automated microbial analyzing device based on flow cytometry techniques to measure the total number of bacteria in water samples within two minutes, by detecting typical patterns of scattered light and fluorescence. We first compared the results of our RDM with plate counting results for five filtered hot spring water samples spiked with three species of bacteria, including Legionella. Inactivation of these samples by chlorine was also assessed by the RDM, a live/dead bacterial fluorescence assay and plate counting. Using the RDM, the lower limit of quantitative bacterial counts in the spiked samples was determined as 3.0×10(3)(3.48log)counts mL(-1). We then used a laboratory model of a hot tub and found that the RDM could monitor the growth curve of naturally occurring heterotrophic bacteria with 1 and 2 days' delayed growth of amoeba and Legionella, respectively, and could also determine the killing curve of these bacteria by chlorination. Finally, samples with ≥3.48 or <3.48log total bacterial counts mL(-1) were tested using the RDM from 149 different hot tubs, and were found to be significantly associated with the positive or negative detection of Legionella with 95% sensitivity and 84% specificity. These findings indicated that the RDM can be used for Legionella control at bathing facilities, especially those where the effectiveness of chlorine is reduced by the presence of Fe(2+), Mn(2+), NH(4)(+), skin debris, and/or biofilms in the water. Copyright © 2011 Elsevier B.V. All rights reserved.
Yun, Xiao; Quarini, Giuseppe L
2017-03-13
We demonstrate a method for the study of the heat and mass transfer and of the freezing phenomena in a subcooled brine environment. Our experiment showed that, under the proper conditions, ice can be produced when water is introduced to a bath of cold brine. To make ice form, in addition to having the brine and water mix, the rate of heat transfer must bypass that of mass transfer. When water is introduced in the form of tiny droplets to the brine surface, the mode of heat and mass transfer is by diffusion. The buoyancy stops water from mixing with the brine underneath, but as the ice grows thicker, it slows down the rate of heat transfer, making ice more difficult to grow as a result. When water is introduced inside the brine in the form of a flow, a number of factors are found to influence how much ice can form. Brine temperature and concentration, which are the driving forces of heat and mass transfer, respectively, can affect the water-to-ice conversion ratio; lower bath temperatures and brine concentrations encourage more ice to form. The flow rheology, which can directly affect both the heat and mass transfer coefficients, is also a key factor. In addition, the flow rheology changes the area of contact of the flow with the bulk fluid.
Changes in the haemostatic system after thermoneutral and hyperthermic water immersion.
Boldt, Leif-Hendrik; Fraszl, Waltraud; Röcker, Lothar; Schefold, Jörg Christian; Steinach, Mathias; Noack, Thilo; Gunga, Hanns-Christian
2008-03-01
Warm water bathing is a popular recreational activity and is frequently used in rehabilitation medicine. Although well tolerated in most cases, there are reports indicating an increased risk of thrombotic events after hot tub bathing. The effects of a 45 min thermoneutral bath followed by a 50 min bath with increasing water temperature (maximum 41 degrees C) until reaching a body core temperature of 39 degrees C on factors of blood coagulation and fibrinolysis were studied in eight healthy male volunteers. Blood was obtained after a 45-min resting period as control and after the thermoneutral and hyperthermic bath as well as after another 45 min recovery period at the end of the study. Hyperthermic immersion (HI) lead to a shortening of activated partial thromboplastin time (aPTT) (P < 0.05). Fibrinogen concentration decreased immediately after HI (P < 0.05) but increased during recovery (P < 0.05). Plasminogen activator inhibitor (PAI) activity decreased during HI (P < 0.05), D-dimer concentration was not found to change. Thrombocyte count increased (P < 0.05) during HI. The increases in tissue-type plasminogen activator concentration as well as leucocyte count during HI were due to haemoconcentration. Prothrombin time, PAI-activity and granulocyte count decreased during thermoneutral immersion (P < 0.05). Warm water bathing leads to haemoconcentration and minimal activation of coagulation. The PAI-1 activity is decreased. A marked risk for thrombotic or bleeding complications during warm water bathing in healthy males could not be ascertained.
Viscosity and density of methanol/water mixtures at low temperatures
NASA Technical Reports Server (NTRS)
Austin, J. G.; Kurata, F.; Swift, G. W.
1968-01-01
Viscosity and density are measured at low temperatures for three methanol/water mixtures. Viscosity is determined by a modified falling cylinder method or a calibrated viscometer. Density is determined by the volume of each mixture contained in a calibrated glass cell placed in a constant-temperature bath.
Foreman, J H; Benson, G J; Foreman, M H
2006-08-01
Horses generate considerable internal heat burdens when exercising. Although common practice for a trainer or groom to place a wet blanket or towel on the dorsum of a hot horse post exercise, there are no data supporting the efficacy of this cooling method. To test the hypothesis that a pre-moistened blanket designed with a multilayered breathable fabric would enhance heat loss in horses post exercise. Eight treadmill-trained horses performed a standardised exercise test (SET) weekly for 3 weeks, with 3 different recovery treatments administered randomly. Pulmonary artery temperature (PAT) was measured via Swan-Ganz catheter. The SET consisted of 10 min at 3.7 m/sec, 3 min at 11.0 m/sec, 25 min at 3.7 m/sec and 20 min of recovery walking at 2.0 m/sec (58 min exercise and recovery under laboratory conditions of 35.0-40.6 degrees C and 27-49% RH). From 3-7 min during recovery, the treadmill was stopped and horses randomly received either: (a) no bath (negative control); (b) a bath consisting of 32 l of 1-4 degrees C water split into 3-4 cycles of bilateral water application (positive control) followed by water removal ('scraping'); or (c) application of a multilayered fabric blanket soaked in 16-19 degrees C water, wrung out, and placed over the dorsum and sides of the horse. PAT was compared using RM ANOVA with the Student Neuman-Keul's test used post hoc to discriminate between treatments at specific points in time. Mean PAT rose with each phase of exercise (P<0.001) and peaked at a mean of 40.2 +/- 0.2 degrees C. During recovery, the cold bath decreased HR and PAT for 9 min after walking resumed (P<0.001-P<0.05). The blanket did not decrease HR or PAT compared to negative control (P>0.05), and both were hotter than the cold bath treatment through 16 min of recovery (P<0.05). A specially-designed cooling blanket failed to reduce PAT when compared to negative control. Cold water bathing decreased HR and PAT but was not effective throughout all of recovery. A specially-designed, pre-moistened multilayered breathable fabric failed to promote evaporative cooling compared to negative control. Cold water baths may need to be repeated throughout recovery to optimise their effect.
Post-industrial river water quality-Fit for bathing again?
Kistemann, Thomas; Schmidt, Alexandra; Flemming, Hans-Curt
2016-10-01
For the Ruhr River, bathing has been prohibited for decades. However, along with significant improvements of the hygienic water quality, there is an increasing demand of using the river for recreational purposes, in particular for bathing. In the "Safe Ruhr" interdisciplinary research project, demands, options and chances for lifting the bathing ban for the Ruhr River were investigated. As being the prominent reason for persisting recreational restrictions, microbiological water quality was in the focus of interest. Not only the faecal indicator organisms (FIOs) as required by the European Bathing Water Directive were considered, but also pathogens such as Salmonella, Pseudomonas aeruginosa, Legionella pneumophila, Campylobacter, Leptospira, enteroviruses and protozoan parasites. In this introductory paper, we firstly relate current recreational desires to historical experiences of river bathing. After recapitulating relevant microbial river contamination sources (predominantly sewage treatment plants, combined sewer overflows, and surface runoffs), we review existing knowledge about the relationships of FIOs and pathogens in rivers designated for recreational purposes, and then trace the evolution, rationale and validity of recreational freshwater quality criteria which are, despite obvious uncertainties, mostly relying on the FIO paradigm. In particular, the representativeness of FIOs is critically discussed. The working programme of Safe Ruhr, aiming at initiating and facilitating a process towards legalisation of Ruhr River bathing, is outlined. Sources of contamination can be technically handled which leaves the actual measures to political decisions. As contaminations are transient, only occasionally exceeding legal limits, a flexible bathing site management, warning bathers of non-safe situations, may amend technical interventions and offer innovative solutions. As a result, a situation-adapted system for lifting of the bathing ban for Ruhr River appears realistic. Copyright © 2016 Elsevier GmbH. All rights reserved.
Changes in Breath Trihalomethane Levels Resulting from Household Water-Use Activities
Gordon, Sydney M.; Brinkman, Marielle C.; Ashley, David L.; Blount, Benjamin C.; Lyu, Christopher; Masters, John; Singer, Philip C.
2006-01-01
Common household water-use activities such as showering, bathing, drinking, and washing clothes or dishes are potentially important contributors to individual exposure to trihalomethanes (THMs), the major class of disinfection by-products of water treated with chlorine. Previous studies have focused on showering or bathing activities. In this study, we selected 12 common water-use activities and determined which may lead to the greatest THM exposures and result in the greatest increase in the internal dose. Seven subjects performed the various water-use activities in two residences served by water utilities with relatively high and moderate total THM levels. To maintain a consistent exposure environment, the activities, exposure times, air exchange rates, water flows, water temperatures, and extraneous THM emissions to the indoor air were carefully controlled. Water, indoor air, blood, and exhaled-breath samples were collected during each exposure session for each activity, in accordance with a strict, well-defined protocol. Although showering (for 10 min) and bathing (for 14 min), as well as machine washing of clothes and opening mechanical dishwashers at the end of the cycle, resulted in substantial increases in indoor air chloroform concentrations, only showering and bathing caused significant increases in the breath chloroform levels. In the case of bromodichloromethane (BDCM), only bathing yielded a significantly higher air level in relation to the preexposure concentration. For chloroform from showering, strong correlations were observed for indoor air and exhaled breath, blood and exhaled breath, indoor air and blood, and tap water and blood. Only water and breath, and blood and breath were significantly associated for chloroform from bathing. For BDCM, significant correlations were obtained for blood and air, and blood and water from showering. Neither dibromochloromethane nor bromoform gave measurable breath concentrations for any of the activities investigated because of their much lower tap-water concentrations. Future studies will address the effects that changes in these common water-use activities may have on exposure. PMID:16581538
Lee, Elaine C; Watson, Greig; Casa, Douglas; Armstrong, Lawrence E; Kraemer, William; Vingren, Jakob L; Spiering, Barry A; Maresh, Carl M
2012-01-01
Cold-water immersion is the criterion standard for treatment of exertional heat illness. Cryotherapy and water immersion also have been explored as ergogenic or recovery aids. The kinetics of inflammatory markers, such as interleukin-6 (IL-6), during cold-water immersion have not been characterized. To characterize serum IL-6 responses to water immersion at 2 temperatures and, therefore, to initiate further research into the multidimensional benefits of immersion and the evidence-based selection of specific, optimal immersion conditions by athletic trainers. Controlled laboratory study. Human performance laboratory Patients or Other Participants: Eight college-aged men (age = 22 ± 3 years, height = 1.76 ± 0.08 m, mass = 77.14 ± 9.77 kg, body fat = 10% ± 3%, and maximal oxygen consumption = 50.48 ± 4.75 mL·kg(-1) min(-1)). Participants were assigned randomly to receive either cold (11.70°C ± 2.02°C, n = 4) or warm (23.50°C ± 1.00°C, n = 4) water-bath conditions after exercise in the heat (temperature = 37°C, relative humidity = 52%) for 90 minutes or until volitional cessation. Whole-body cooling rates were greater in the cold water-bath condition for the first 6 minutes of water immersion, but during the 90-minute, postexercise recovery, participants in the warm and cold water-bath conditions experienced similar overall whole-body cooling. Heart rate responses were similar for both groups. Participants in the cold water-bath condition experienced an overall slight increase (30.54% ± 77.37%) in IL-6 concentration, and participants in the warm water-bath condition experienced an overall decrease (-69.76% ± 15.23%). We have provided seed evidence that cold-water immersion is related to subtle IL-6 increases from postexercise values and that warmer water-bath temperatures might dampen this increase. Further research will elucidate any anti-inflammatory benefit associated with water-immersion treatment and possible multidimensional uses of cooling therapies.
BATHING BEACH MONITORING PROTOCOLS/COMMUNICATING SWIMMING ACTIVITY RISK TO THE PUBLIC
Current Environmental Protection Agency (EPA) recommended monitoring practices for bathing beach water quality were suggested in 1968, as a part of the fecal coliform guideline developed by the Federal Water Pollution Control Administration. The guideline stated that five water ...
Zhang, Hongyan; Sun, Pan; Liu, Chang; Gao, Huanyu; Xu, Linru; Fang, Jin; Wang, Meng; Liu, Jinling; Xu, Shukun
2011-01-01
Functionalized CdTe-CdS core-shell quantum dots (QDs) were synthesized in aqueous solution via water-bathing combined hydrothermal method using L-cysteine (L-Cys) as a stabilizer. This method possesses both the advantages of water-bathing and hydrothermal methods for preparing high-quality QDs with markedly reduced synthesis time, and better stability than a lone hydrothermal method. The QDs were characterized by transmission electronic microscopy and powder X-ray diffraction and X-ray photoelectron spectroscopy. The CdTe-CdS QDs with core-shell structure showed both enhanced fluorescence and better photo stability than nude CdTe QDs. After conjugating with antibody rabbit anti-CEACAM8 (CD67), the as-prepared l-Cys capped CdTe-CdS QDs were successfully used as fluorescent probes for the direct immuno-labeling and imaging of HeLa cells. It was indicated that this kind of QD would have application potential in bio-labeling and cell imaging. Copyright © 2009 John Wiley & Sons, Ltd.
Lee, Young Bok; Kim, Su Jin; Park, Sae Mi; Lee, Kyung Ho; Han, Hyung Jin; Yu, Dong Soo; Woo, So Youn; Yun, Seong Taek; Hamm, Se-Yeong; Kim, Hong Jig
2016-01-01
Background Although the therapeutic mechanism of balneotherapy for atopic dermatitis has not been clarified, many atopic patients who visit thermomineral springs have shown clinical improvements. Objective This study was aimed to evaluate the immunomodulatory effect of thermomineral water balneotherapy on the atopic dermatitis murine model. Methods The oxazolone-induced atopic dermatitis murine model was used to evaluate the therapeutic effect of balneotherapy with Deokgu thermomineral water compared with distilled water. Histologic evaluation and confocal microscopic imaging were performed to analyze the lesional expression of cluster-of-differentiation (CD)4 and forkhead box p3 (Foxp3). Lesional mRNA expression of interleukin (IL) 33, thymic stromal lymphopoietin (TSLP), and Foxp3 was evaluated by real-time reverse transcription polymerase chain reaction. Results Compared with the distilled water bath group, confocal microscopic evaluation of CD4 and Foxp3 merged images showed increased expression of regulatory T cells in the thermomineral balneotherapy group. The lesional mRNA level of IL-33 showed a reduced trend in the thermomineral balneotherapy group, whereas the level of mRNA of Foxp3 was increased. TSLP showed a decreased trend in both distilled water and thermomineral water bath groups. There was a trend of reduced expression in lesional IL-33 mRNA but increased cell count of CD4+ Foxp3+ regulatory T cells in thermomineral balneotherapy compared with distilled water bath. Conclusion Therefore, thermomineral balneotherapy can be an effective and safe adjuvant therapeutic option for atopic dermatitis. PMID:27081266
Kim, Chang-Hyun; Cheong, Kyung Ah; Lim, Won Suk; Park, Hyung-Moo; Lee, Ai-Young
2016-01-01
Light-emitting diode (LED) phototherapy and water bath therapy have beneficial effect on atopic dermatitis (AD)-like skin disease. However, not all current treatments work well and alternative therapies are need. The contribution of combination therapy with low-dose 850 nm LED and water bath was investigated on dermatophagoides farina (Df)-induced dermatitis in NC/Nga mice. Low-dose LED (10, 15, and 20 J/cm(2) ) irradiation, water bath (36 ± 1°C) were administered separately and together to the Df-induced NC/Nga mice in acrylic jar once a day for 2 weeks. Combined therapy with low-dose LED therapy and water bath therapy significantly ameliorated the development of AD-like skin lesions. These effects were correlated with the suppression of total IgE, NO, histamine, and Th2-mediated immune responses. Furthermore, combination therapy significantly reduced the infiltration of inflammatory cells and the induction of thymic stromal lymphopoietin (TSLP) in the skin lesions. The beneficial therapeutic effects of this combination therapy might regulate by the inhibition of various immunological responses including Th2-mediated immune responses, inflammatory mediators such as IgE, histamine, and NO, as well as inflammatory cells. The combination therapy of LED and water bath might be used as an efficacious, safe, and steroid-free alternative therapeutic strategy for the treatment of AD. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Method for foam encapsulating laser targets
Hendricks, Charles D.
1977-01-01
Foam encapsulated laser fusion targets are made by positioning a fusion fuel-filled sphere within a mold cavity of suitable configuration and dimensions, and then filling the cavity with a material capable of producing a low density, microcellular foam, such as cellulose acetate dissolved in an acetone-based solvent. The mold assembly is dipped into an ice water bath to gel the material and thereafter soaked in the water bath to leach out undesired components, after which the gel is frozen, then freeze-dried wherein water and solvents sublime and the gel structure solidifies into a low-density microcellular foam, thereafter the resulting foam encapsulated target is removed from the mold cavity. The fuel-filled sphere is surrounded by foam having a thickness of about 10 to 100 .mu.m, a cell size of less than 2 .mu.m, and density of 0.065 to 0.6 .times. 10.sup.3 kg/m.sup.3. Various configured foam-encapsulated targets capable of being made by this encapsulation method are illustrated.
Microbiological investigations on the water of a thermal bath at Budapest.
Szuróczki, Sára; Kéki, Zsuzsa; Káli, Szandra; Lippai, Anett; Márialigeti, Károly; Tóth, Erika
2016-06-01
Thermal baths are unique aquatic environments combining a wide variety of natural and anthropogenic ecological factors, which also appear in their microbiological state. There is limited information on the microbiology of thermal baths in their complexity, tracking community shifts from the thermal wells to the pools. In the present study, the natural microbial community of well and pool waters in Gellért bath was studied in detail by cultivation-based techniques. To isolate bacteria, 10% R2A and minimal synthetic media (with "bath water") with agar-agar and gellan gum were used after prolonged incubation time; moreover, polyurethane blocks covered with media were also applied. Strains were identified by sequencing their 16S rRNA gene after grouping them by amplified rDNA restriction analysis. From each sample, the dominance of Alphaproteobacteria was characteristic though their diversity differed among samples. Members of Actinobacteria, Firmicutes, Beta- and Gamma-proteobacteria, Deinococcus-Thermus, and Bacteroidetes were also identified. Representatives of Deinococcus-Thermus phylum appeared only in the pool water. The largest groups in the pool water belonged to the Tistrella and Chelatococcus genera. The most dominant member in the well water was a new taxon, its similarity to Hartmannibacter diazotrophicus as closest relative was 93.93%.
Increase in outbreaks of gastroenteritis linked to bathing water in Finland in summer 2014
Kauppinen, Ari; Al-Hello, Haider; Zacheus, Outi; Kilponen, Jaana; Maunula, Leena; Huusko, Sari; Lappalainen, Maija; Miettinen, Ilkka; Blomqvist, Soile; Rimhanen-Finne, Ruska
2017-01-01
An increased number of suspected outbreaks of gastroenteritis linked to bathing water were reported to the Finnish food- and waterborne outbreak (FWO) registry in July and August 2014. The investigation reports were assessed by a national outbreak investigation panel. Eight confirmed outbreaks were identified among the 15 suspected outbreaks linked to bathing water that had been reported to the FWO registry. According to the outbreak investigation reports, 1,453 persons fell ill during these outbreaks. Epidemiological and microbiological data revealed noroviruses as the main causative agents. During the outbreaks, exceptionally warm weather had boosted the use of beaches. Six of eight outbreaks occurred at small lakes; for those, the investigation strongly suggested that the beach users were the source of contamination. In one of those eight outbreaks, an external source of contamination was identified and elevated levels of faecal indicator bacteria (FIB) were noted in water. In the remaining outbreaks, FIB analyses were insufficient to describe the hygienic quality of the water. Restrictions against bathing proved effective in controlling the outbreaks. In spring 2015, the National Institute for Health and Welfare (THL) and the National Supervisory Authority for Welfare and Health (Valvira) published guidelines for outbreak control to prevent bathing water outbreaks. PMID:28251888
Diwan, Vishal; Purohit, Manju; Chandran, Salesh; Parashar, Vivek; Shah, Harshada; Mahadik, Vijay K; Stålsby Lundborg, Cecilia; Tamhankar, Ashok J
2017-05-29
Antibiotic resistance (ABR) is one of the major health emergencies for global society. Little is known about the ABR of environmental bacteria and therefore it is important to understand ABR reservoirs in the environment and their potential impact on health. Quantitative and qualitative data will be collected during a 3-year follow-up study of a river associated with religious mass-bathing in Central India. Surface-water and sediment samples will be collected from seven locations at regular intervals for 3 years during religious mass-bathing and in absence of it to monitor water-quality, antibiotic residues, resistant bacteria, antibiotic resistance genes and metals. Approval has been obtained from the Ethics Committee of R.D. Gardi Medical College, Ujjain, India (No. 2013/07/17-311). The results will address the issue of antibiotic residues and antibiotic resistance with a focus on a river environment in India within a typical socio-behavioural context of religious mass-bathing. It will enhance our understanding about the relationship between antibiotic residue levels, water-quality, heavy metals and antibiotic resistance patterns in Escherichia coli isolated from river-water and sediment, and seasonal differences that are associated with religious mass-bathing. We will also document, identify and clarify the genetic differences/similarities relating to phenotypic antibiotic resistance in bacteria in rivers during religious mass-bathing or during periods when there is no mass-bathing.
Andersen, S T; Erichsen, A C; Mark, O; Albrechtsen, H-J
2013-12-01
Quantitative microbial risk assessments (QMRAs) often lack data on water quality leading to great uncertainty in the QMRA because of the many assumptions. The quantity of waste water contamination was estimated and included in a QMRA on an extreme rain event leading to combined sewer overflow (CSO) to bathing water where an ironman competition later took place. Two dynamic models, (1) a drainage model and (2) a 3D hydrodynamic model, estimated the dilution of waste water from source to recipient. The drainage model estimated that 2.6% of waste water was left in the system before CSO and the hydrodynamic model estimated that 4.8% of the recipient bathing water came from the CSO, so on average there was 0.13% of waste water in the bathing water during the ironman competition. The total estimated incidence rate from a conservative estimate of the pathogenic load of five reference pathogens was 42%, comparable to 55% in an epidemiological study of the case. The combination of applying dynamic models and exposure data led to an improved QMRA that included an estimate of the dilution factor. This approach has not been described previously.
Performance of Flow and Heat Transfer in a Hot-Dip Round Coreless Galvanizing Bath
NASA Astrophysics Data System (ADS)
Yue, Qiang; Zhang, Chengbo; Xu, Yong; Zhou, Li; Kong, Hui; Wang, Jia
2017-04-01
Flow field in a coreless hot-dip galvanizing pot was investigated through a water modeling experiment. The corresponding velocity vector was measured using an acoustic Doppler velocimeter. The flow field of molten zinc in the bath was also analyzed. Steel strip velocities from 1.7 to 2.7 m/s were adopted to determine the effect of steel strip velocity on the molten zinc flow in the bath. A large vortex filled the space at the right side of the sink roll, under linear speed from 1.0 to 2.7 m/s and width from 1.0 to 1.3 m of the steel strip, because of the effects of wall and shear stress. The results of the water modeling experiment were compared with those of numerical simulations. In the simulation, Maxwell equations were solved using finite element method to obtain magnetic flux density, electromagnetic force, and Joule heating. The Joule heating rate reached the maximum and minimum values near the side wall and at the core of the bath, respectively, because of the effect of skin and proximity. In an industrial-sized model, the molten zinc flow and temperature fields driven by electromagnetic force and Joule heating in the inductor of a coreless galvanizing bath were numerically simulated. The results indicated that the direction of electromagnetic force concentrated at the center of the galvanizing pot horizontal planes and exerted a pinch effect on molten zinc. Consequently, molten zinc in the pot was stirred by electromagnetic force. Under molten zinc flow and electromagnetic force stirring, the temperature of the molten zinc became homogeneous throughout the bath. This study provides a basis for optimizing electromagnetic fields in coreless induction pot and fine-tuning the design of steel strip parameters.
[Turpentine white emulsion baths in the rehabilation in patients with sexual dysfunctions].
Karpukhin, I V; Li, A A; Gusev, M E
2000-01-01
100 patients with sexual dysfunction (SD) and 20 SD patients took turpentine white emulsion baths and sodium chloride baths, respectively. The turpentine baths were given with step-by-step rise in turpentine concentration from 20 to 50 ml per 200 l of water, temperature 36-37 degrees C, duration of the procedure 10-15 min. The course consisted of 10-12 procedures which were conducted daily or each other day. The turpentine baths were more effective than sodium chloride baths (85 vs 50%, respectively).
Lee, Elaine C.; Watson, Greig; Casa, Douglas; Armstrong, Lawrence E.; Kraemer, William; Vingren, Jakob L.; Spiering, Barry A.; Maresh, Carl M.
2012-01-01
Context Cold-water immersion is the criterion standard for treatment of exertional heat illness. Cryotherapy and water immersion also have been explored as ergogenic or recovery aids. The kinetics of inflammatory markers, such as interleukin-6 (IL-6), during cold-water immersion have not been characterized. Objective To characterize serum IL-6 responses to water immersion at 2 temperatures and, therefore, to initiate further research into the multidimensional benefits of immersion and the evidence-based selection of specific, optimal immersion conditions by athletic trainers. Design Controlled laboratory study. Setting Human performance laboratory Patients or Other Participants Eight college-aged men (age = 22 ± 3 years, height = 1.76 ± 0.08 m, mass = 77.14 ± 9.77 kg, body fat = 10% ± 3%, and maximal oxygen consumption = 50.48 ± 4.75 mL·kg−1·min−1). Main Outcome Measures Participants were assigned randomly to receive either cold (11.70°C ± 2.02°C, n = 4) or warm (23.50°C ± 1.00°C, n = 4) water-bath conditions after exercise in the heat (temperature = 37°C, relative humidity = 52%) for 90 minutes or until volitional cessation. Results Whole-body cooling rates were greater in the cold water-bath condition for the first 6 minutes of water immersion, but during the 90-minute, postexercise recovery, participants in the warm and cold water-bath conditions experienced similar overall whole-body cooling. Heart rate responses were similar for both groups. Participants in the cold water-bath condition experienced an overall slight increase (30.54% ± 77.37%) in IL-6 concentration, and participants in the warm water-bath condition experienced an overall decrease (−69.76% ± 15.23%). Conclusions We have provided seed evidence that cold-water immersion is related to subtle IL-6 increases from postexercise values and that warmer water-bath temperatures might dampen this increase. Further research will elucidate any anti-inflammatory benefit associated with water-immersion treatment and possible multidimensional uses of cooling therapies. PMID:23182014
Cerebral autoregulation during whole-body hypothermia and hyperthermia stimulus.
Doering, T J; Aaslid, R; Steuernagel, B; Brix, J; Niederstadt, C; Breull, A; Schneider, B; Fischer, G C
1999-01-01
The purpose of the study contained herein was to investigate the effects of old traditional physiotherapeutic treatments on cerebral autoregulation. Treatment consisted of complete body immersion in cold or warm water baths. Fifteen volunteers were investigated by means of transcranial Doppler sonography and a servo-controlled noninvasive device for blood pressure measuring. One group of 8 volunteers (mean age, 27.2+/-3.5 yr; gender, 3 females/5 males) was subjected to cold baths of 22 degrees C for 20 min Another group of 7 volunteers (mean age, 52.1+/-8.5 yr; gender, 4 females/3 males) took hyperthermic baths at rising water temperatures from 36 degrees to 42 degrees C, increased by 1 degree C every 5 min. Each volunteer in both groups underwent autoregulation tests two to four times before, during, and after the thermic bath. Dynamic autoregulation was measured by the response of cerebral blood flow velocity to a transient decrease of the mean arterial blood pressure, induced by rapid deflation of thigh cuffs. The autoregulation index, i.e., a measure of the speed of change of cerebral autoregulation, was used to quantify the response. Further parameters were core temperature, blood pressure (mm Hg) and CO2et. During hypothermic baths, core temperature decreased by 0.3 degrees C (P = 0.001), measured between preliminary phase and the end of the bath; the autoregulation index decreased significantly (P < 0.05) from 5.3 before the bath to 4.25 during the bath. During hyperthermic baths, the autoregulation index increased from 6.0 to 7.5 and 8.9 (P < 0.001), with an increase of core temperature of 0.4 degrees C. The main cerebral autoregulation system is dependent on changes of core temperature, provoked by hypothermic or hyperthermic whole-body thermostimulus. Application of hyperthermic baths increased the autoregulation index, and hypothermic baths decreased the autoregulation index. Further studies are needed to prove the positive effects of thermo-stimulating water applications on cerebral hemodynamics in patients with cerebral diseases.
Biering-Sørensen, F; Schröder, A K; Wilhelmsen, M; Lomberg, B; Nielsen, H; Høiby, N
2000-02-01
To evaluate the bacterial contamination of the water from the microflora of pressure ulcers in para- and tetraplegic patients, when they were exercising in water at 36 degrees C for half an hour. Twelve spinal cord lesioned (SCL) patients with ulcers participated, and six of the 12 SCL patients with healed ulcers constituted a control group. The evaluation was performed both with and without the ulcer covered with a moisture reactive occlusive dressing, DuoDERM. Bacterial samples were taken from the bath-water before and after the exercise programmes and additionally specimens were obtained from the ulcer, the patients skin and urine, and from the skin of the physiotherapist who exercised the patient. A similar procedure was carried out in the controls. The bacteriologic analyses showed no significant difference in the contamination of the bath-water after exercising with or without DuoDERM covering the ulcers. In half of the patients DuoDERM loosened. After all exercise programmes with or without DuoDERM dressing the water was contaminated with facultative aerobic intestinal bacteria, ie E. faecalis and Enterobacteriaceae (E. coli, Klebsiella species, Proteus species, Enterobacter species). In nearly one-third of the exercise sessions the bath-water was contaminated with P. aeruginosa before starting, and after the exercise programmes one fourth of the ulcers were colonized with these pathogens. The water specimen showed the bacteria from the intestine to be much more prominent than the bacteria coming from the ulcers. Thus the pressure ulcers were of minor importance for the bath-water and ought not to prohibit patients from the potential benefits of water exercise, but chlorination of the water in the training pool seems appropriate.
Osmosis in Cortical Collecting Tubules
Schafer, James A.; Troutman, Susan L.; Andreoli, Thomas E.
1974-01-01
The present experiments were designed to evaluate the effects of varying the osmolality of luminal solutions on the antidiuretic hormone (ADH)-independent water and solute permeability properties of isolated rabbit cortical collecting tubules. In the absence of ADH, the osmotic water permeability coefficient (cm s–1) Pfl→b, computed from volume flows from hypotonic lumen to isotonic bath, was 20 ± 4 x 10–4 (SEM); the value of Pfb→l in the absence of ADH, computed from volume flows from isotonic bath to hypertonic lumen, was 88 ± 15 x 10–4 cm s–1. We also measured apparent urea permeability coefficients (cm s–1) from 14C-urea fluxes from lumen to bath (P DDurea l→b) and from bath to lumen (P DDurea b→l). For hypotonic luminal solutions and isotonic bathing solutions, P DDurea l→b was 0.045 ± 0.004 x 10–4 and was unaffected by ADH. The ADH-independent values of P DDurea l→b and P urea b→l were, respectively, 0.216 ± 0.022 x 10–4 cm s–1 and 0.033 ± 0.002 x 10–4 cm s–1 for isotonic bathing solutions and luminal solutions made hypertonic with urea, i.e., there was an absolute increase in urea permeability and asymmetry of urea fluxes. Significantly, P DDurea l→b did not rise when luminal hypertonicity was produced by sucrose; and, bathing fluid hypertonicity did not alter tubular permeability to water or to urea. We interpret these data to indicate that luminal hypertonicity increased the leakiness of tight junctions to water and urea but not sucrose. Since the value of Pfb→l in the absence of ADH, when tight junctions were open to urea, was approximately half of the value of Pfl→b in the presence of ADH, when tight junctions were closed to urea, we conclude that tight junctions are negligible paracellular shunts for lumen to bath osmosis with ADH. These findings, together with those in the preceding paper, are discussed in terms of a solubility-diffusion model for water permeation in which ADH increases water solubility in luminal plasma membranes. PMID:4846768
Enterobiasis (Pinworm Infection) FAQs
... of pinworm eggs in thousands of gallons of water (the amount typically found in pools) makes the chance of infection unlikely. Back To Top My little kids like to co-bathe – could this ... of bath water. Careful handling and frequent changing of underclothing, night ...
Entz, Michael; King, D Ryan; Poelzing, Steven
2017-12-01
With the sudden increase in affordable manufacturing technologies, the relationship between experimentalists and the designing process for laboratory equipment is rapidly changing. While experimentalists are still dependent on engineers and manufacturers for precision electrical, mechanical, and optical equipment, it has become a realistic option for in house manufacturing of other laboratory equipment with less precise design requirements. This is possible due to decreasing costs and increasing functionality of desktop three-dimensional (3-D) printers and 3-D design software. With traditional manufacturing methods, iterative design processes are expensive and time consuming, and making more than one copy of a custom piece of equipment is prohibitive. Here, we provide an overview to design a tissue bath and stabilizer for a customizable, suspended, whole heart optical mapping apparatus that can be produced significantly faster and less expensive than conventional manufacturing techniques. This was accomplished through a series of design steps to prevent fluid leakage in the areas where the optical imaging glass was attached to the 3-D printed bath. A combination of an acetone dip along with adhesive was found to create a water tight bath. Optical mapping was used to quantify cardiac conduction velocity and action potential duration to compare 3-D printed baths to a bath that was designed and manufactured in a machine shop. Importantly, the manufacturing method did not significantly affect conduction, action potential duration, or contraction, suggesting that 3-D printed baths are equally effective for optical mapping experiments. NEW & NOTEWORTHY This article details three-dimensional printable equipment for use in suspended whole heart optical mapping experiments. This equipment is less expensive than conventional manufactured equipment as well as easily customizable to the experimentalist. The baths can be waterproofed using only a three-dimensional printer, acetone, a glass microscope slide, c-clamps, and adhesive. Copyright © 2017 the American Physiological Society.
The U.S. EPA’s in vitro bioaccessibility (IVBA) method 9200.1-86 defines a validated analytical procedure for the determination of lead bioaccessibility in contaminated soils. The method requires the use of a custom-fabricated extraction device that uses a heated water bath for ...
USDA-ARS?s Scientific Manuscript database
Falling number, a procedure that indirectly gauges germination enzyme activity in wheat by its measurement of the viscous behavior of a heated starch-water mixture, is affected by the immersion water bath temperature. Maintained at boiling point, the water bath temperature is determined by barometr...
9 CFR 325.13 - Denaturing procedures.
Code of Federal Regulations, 2012 CFR
2012-01-01
... water, 40 parts liquid detergent, and 40 parts oil of citronella, or other proprietary substance... immersion in a water bath, then immersing it for 1 minute in a solution of 0.022 percent FD&C yellow No. 5... immersion in a water bath, then dipping it in a solution of 0.0625 percent ferric acid; and (5) When meat...
9 CFR 325.13 - Denaturing procedures.
Code of Federal Regulations, 2013 CFR
2013-01-01
... water, 40 parts liquid detergent, and 40 parts oil of citronella, or other proprietary substance... immersion in a water bath, then immersing it for 1 minute in a solution of 0.022 percent FD&C yellow No. 5... immersion in a water bath, then dipping it in a solution of 0.0625 percent ferric acid; and (5) When meat...
9 CFR 325.13 - Denaturing procedures.
Code of Federal Regulations, 2014 CFR
2014-01-01
... water, 40 parts liquid detergent, and 40 parts oil of citronella, or other proprietary substance... immersion in a water bath, then immersing it for 1 minute in a solution of 0.022 percent FD&C yellow No. 5... immersion in a water bath, then dipping it in a solution of 0.0625 percent ferric acid; and (5) When meat...
Obiri-Danso, K; Jones, K
1999-12-01
Two freshwater bathing sites, the Crook O'Lune and the University Boathouse, on the River Lune in the north-west of England, were monitored over a 2 year period for the faecal indicators, faecal coliforms and faecal streptococci, the pathogens, Salmonella and Campylobacter, and compliance with the EU Directive on Bathing Water Quality. Faecal indicator numbers showed no seasonal variation, with numbers in the bathing season similar to those in the non-bathing season. They were consistently above the EU Guideline and Imperative standards so that if the EU Bathing Water Quality Directive (76/160/EEC) were applied, neither site would comply. Faecal indicator numbers in the sediments were an order of magnitude higher than in the overlying water. Campylobacter numbers showed seasonal variation in the water with higher counts in winter than in the summer, although numbers were low. Higher numbers were found in the sediments but there was no seasonal variation. Analysis of various inputs showed that indicators and campylobacters came from a mixture of sources, namely a sewage treatment works, agricultural run-off, streams and mallards. Microbial numbers in the water at the Crook O'Lune, which is closer to the sources of pollution, were twice those at the Boathouse. In the sediments they were six to eight times higher. Faecal coliforms were all identified as Escherichia coli of which 80% were a single biotype. Faecal streptococci were all enterococci of which 55% were E. avium, 38% E. faecalis and 7% E. durans. Salmonella was not isolated from either the water column or the sediments. Campylobacters were mainly Camp. jejuni, followed by Camp. coli, UPTC and Camp. lari.
Maestre, Yolanda; Parés, David; Salvans, Silvia; Ibáñez-Zafón, Inés; Nve, Esther; Pons, Maria-José; Martínez-Casas, Isidro; Pascual, Marta; Pera, Miguel; Grande, Luis
2010-08-01
The popular belief advocates the use of sitz (sitting) baths with cold water for the treatment of acute anal pain, but clinical practice guides recommend the use of hot water for its known effect on the at-rest anal pressure. The objective of the study was to examine the analgesic effect on the quality of life, manometer data and clinical progress, of the two temperatures in sitz baths in patients with anal pain. A randomised clinical trial on patients with acute anal pain due to haemorrhoids or anal fissures, divided into Group 1: Sitz baths with water at a temperature of less than 15 degrees C, and Group 2: Baths with a water temperature above 30 degrees C. The analgesia was the same in both groups. An analysis was made of the pain at 7 days (visual analogue scale), quality of life (SF-36), anal at-rest pressure and disease progress. Of the 27 eligible patients, 24 were randomised (Group 1: n=12 y Group 2: n=12). There were no statistical differences in pain, but it remained stable in Group 1, but gradually decreased in the patients of Group 2, the difference being in the pain scores on the first day compared to the seventh in Group 2 (p=0.244). The rest of the variables were similar. There were no statistically significant differences in pain control from day 1 to day 7 in the Group with sitz baths with hot water. (ISRCTN Number: 50105150).
Strathmann, Martin; Horstkott, Marina; Koch, Christoph; Gayer, Uta; Wingender, Jost
2016-10-01
Along the intense industrialization of the Ruhr valley (Germany), the River Ruhr became increasingly polluted. Over time, using it for recreational purposes became a serious health hazard and bathing was banned due to chemical and microbiological risks. The purpose of the collaborative project "Safe Ruhr" was to verify the current status and to provide a scientific basis for lifting the bathing ban. As the river also provides a raw water source for drinking water production, it was investigated how well the treatment procedures control possible hygienic risks. As study area, the barrier Lake Baldeney was chosen as it embraces earlier bathing sites and tributes to river bank filtration water for drinking water treatment plants. The hygienic condition of the river water was determined over 18 months by measuring general physical, chemical and microbiological water quality parameters including fecal indicators, bacterial obligate and facultative pathogens, parasitic protozoa, enteric viruses and schistosome parasites (Trichobilharzia). Samples were taken at eight locations including sites before and after receiving the discharge of stormwater and treated wastewater, potential future bathing sites and a raw water abstraction point for potable water production. In summary, for all investigated physico-chemical parameters no significant difference between the eight investigated sampling locations on a distinct sampling date were observed. This study focused on hygienically relevant bacteria and parasitic protozoa. Fecal indicators, Escherichia coli, intestinal enterococci and Clostridium perfringens as well as coliform bacteria were detected in 94-100% of the water samples. Enteric pathogens, including Campylobacter spp. and Salmonella enterica, were isolated from 33% and 28% of the samples, respectively, in relatively low concentrations. Among the environmental facultative pathogens, P. aeruginosa was detected at a high frequency of 82% of all samples, but in low numbers, while Aeromonas spp. were found in all water samples in relative high concentrations. The levels of all target organisms were not clearly associated with sources of pollution, with the exception of slightly enhanced numbers of coliform bacteria and E. coli downstream of a sewage discharge point from a wastewater treatment plant. Seasonal variations were observed with higher detection rates of Campylobacter spp. in winter and S. enterica in autumn and winter in contrast to the other bacterial groups, which showed no significant fluctuations throughout the year. Precipitation within two days prior to sampling resulted in a trend of enhanced numbers of coliform bacteria, E. coli, intestinal enterococci and Aeromonas. Sampling and analysis of parasitic protozoa was carried out in accordance to the European bathing water guideline and the ISO 15553 method. Characteristics of the river (flow, vegetation, birds protection zone, bathing of people, sewage etc.) were compared to the number of organisms detected. All in all 184 samples were investigated for Cryptosporidium spp. and Giardia spp. 80% of the samples were positive for Giardia spp. with a mean of 5cysts/100l (0.1-157.9). Highest values were achieved in autumn and winter, lowest values during the assumed bathing season. There seemed to be a trend to lower values in and after a reservoir in the river course, but with no statistical significance. A statistical significance could be shown for higher concentrations after heavy rainfall that led to discharge of combined sewage overflows in the city of Essen. Only 29% of the samples were positive for Cryptosporidium spp. with a single maximum value of 27.7 and all other concentrations below 5 oocysts/100l. On a low level there seemed to be slightly higher findings during summer and bathing season than in autumn and winter. No correlation to heavy rainfall could be found. The findings correspond to earlier results from the River Rhine (Germany). The influence of sewage on the water quality of the Ruhr could be shown from the correlation of Giardia load and activity of combined sewage overflows after heavy rainfall. The rare and low findings of Cryptosporidium spp. lead to the same conclusion, that microbial water quality in the investigation area is rather influenced from sewage water than from diffuse water sources into the River Ruhr. Copyright © 2016 Elsevier GmbH. All rights reserved.
40 CFR Appendix A to Part 80 - Test for the Determination of Phosphorus in Gasoline
Code of Federal Regulations, 2013 CFR
2013-07-01
... Specification for Filter Paper for Use in Chemical Analysis. 3. Summary of method. 3.1 Organic matter in the...) during the entire period of sample heating. Note 1: If the temperature of the hot water bath drops below... 100-ml volumetric flasks submerged to the mark in ice water. 4.4 Filter Paper, for quantitative...
40 CFR Appendix A to Part 80 - Test for the Determination of Phosphorus in Gasoline
Code of Federal Regulations, 2012 CFR
2012-07-01
... Specification for Filter Paper for Use in Chemical Analysis. 3. Summary of method. 3.1 Organic matter in the...) during the entire period of sample heating. Note 1: If the temperature of the hot water bath drops below... 100-ml volumetric flasks submerged to the mark in ice water. 4.4 Filter Paper, for quantitative...
40 CFR Appendix A to Part 80 - Test for the Determination of Phosphorus in Gasoline
Code of Federal Regulations, 2014 CFR
2014-07-01
... Specification for Filter Paper for Use in Chemical Analysis. 3. Summary of method. 3.1 Organic matter in the...) during the entire period of sample heating. Note 1: If the temperature of the hot water bath drops below... 100-ml volumetric flasks submerged to the mark in ice water. 4.4 Filter Paper, for quantitative...
Díaz, P; Linares, M B; Egea, M; Auqui, S M; Garrido, M D
2014-12-01
The aim was to study the effect of the incubation method and TBA reagent (concentration/solvent) on yellow pigment interference in meat products. Distillates from red sausage, sucrose, malondialdehyde and a mixture of sucrose-malondialdehyde were reacted with four different TBA solutions at five different temperature/time relations. Two TBA solutions were prepared at 20mM using 90% glacial acetic acid or 3.86% perchloric acid. In addition, an 80mM TBA solution was prepared using distilled water adjusted to pH4 and another using 0.8% TBA in distilled water. The temperature/time relations were: (1) 35min in a boiling water bath; (2) 70°C/30min; (3) 40°C/90min; (4) room temperature (r.t.) (24°C) in dark conditions for 20h; and (5) 60min in a boiling water bath. The results showed that aqueous or diluted acid solutions of TBA reagent and the application of 100°C for less than 1h provided the best conditions to minimize the presence of yellow pigments and maximize pink pigment formation in meat products. Copyright © 2014 Elsevier Ltd. All rights reserved.
The treatment of scrofula in Ferrara (Italy) in the 19th century.
Vicentini, Chiara Beatrice; Altieri, Lorenzo; Guidi, Enrica; Contini, Carlo; Manfredini, Stefano
2012-06-01
The therapeutic approaches used against scrofula in the 19th Century in Ferrara are discussed. In the manuscripts and treatises of the time treasured in the town's libraries, hygienic and dietetic rules and treatment of this illness were described. In particular, baths and mineral water spas (sulphurous, ferruginous and other mineral waters, such as a bromo-iodine-salt water) and the sea-bathing establishment were recommended. The remedies reported in Campana's Pharmacopoeia ferrarese and the efficacious treatments employed in St Anna Hospital are discussed. The Committee and its President, Marquis Giovanni Manfredini, decided to cure the scrofulous in bathing establishments.
Baroni, S; Marazziti, D; Consoli, G; Picchetti, M; Catena-Dell'Osso, M; Galassi, A
2012-05-01
Although the beneficial effects of balneotherapy have been recognized since a long time, a few information is available on the biological mechanisms underlying them and the subjective feelings of increased well-being and mood. The links between the serotonin (5-HT) system and mood prompted us to investigate the 5-HT platelet transporter (SERT), which is considered a reliable, peripheral marker of the same structure present in presynaptic neurons, in 30 healthy volunteers before (t0) and 30 minutes after (t1) thermal balneotherapy with ozonized water, as compared with a similar group who underwent a bath in non-mineral water. MATERIALS AN METHODS: The SERT was evaluated by means of the specific binding of 3H-paroxetine (3H-Par) to platelet membranes. Equilibrium-saturation binding data, the maximal binding capacity (Bmax) and the dissociation constant (Kd), were obtained by means of the Scatchard analysis. The results showed that, while Bmax values did not change in both groups, the Kd values decreased significantly at t1 only in those subjects who bathed in ozonized water. The results of this study, while showing a decrease of the dissociation constant (Kd) which is the inverse of affinity constant, of 3H-Par binding to SERT in all subjects after balneotherapy and not in those bathing in normal water, suggest that SERT modifications may be related to a specific effect of ozonized water and, perhaps, also to the increased sense of well-being.
Stoner, L C; Roch-Ramel, F
1979-10-01
Descending limbs of Henle's loops from rabbits were perfused in vitro. Using techniques where the collecting pipets permitted cannulation of the tubule, we were able to maintain reasonable flow rates at lower perfusion reservoir heights than are required with a conventional "Sylgard seal" pipet. The bath was either isosmotic to the perfusate, or was made 300 mOsm hyperosmotic using urea. Net water reabsorption did not occur in tubules perfused at low pressure (average reservoir height = 26 cm H2O) even when the bath was hyperosmotic: delta Jv = -0.06 +/- 0.18 nl/min (n = 7). Observed increases in sodium concentration and osmolality of collected fluid, when the bath was made hyperosmotic, were 16 +/- 8 mM (n - 7) and 254 +/- 38 mOsm (n = 7), respectively. Presumably the large increase in osmolality of the collected fluid was due to entrance of urea. When the "Sylgard seal" collecting end was utilized higher perfusion reservoir heights had to be used to maintain flow (mean height 66 cm H2O). These tubules were highly permeable to water as reported by others for this tubule segment. In the presence of a hyperosmotic bath water extrusion resulted in a dramatic increase in the osmolality of the collected fluid (312 +/- 5 mOsm; 7 tubules) which was almost completely accounted for by an increase in sodium concentration (153 +/- 8 mmole/l; 6 tubules). The 14C urea permeability (measured lumen to bath) of descending limbs in a 300 mOsm bath was 0.64 x 10(-7) cm2 . s-1 +/- 0.23 x 10(-7) (11 tubules). When the bath was made hyperosmotic using urea or raffinose the 14C urea permeability increased significantly.
Code of Federal Regulations, 2013 CFR
2013-01-01
... coloring, 40 parts water, 40 parts liquid detergent, and 40 parts oil of citronella, or other proprietary... dipping it in a solution of 0.0625 percent tannic acid, followed by immersion in a water bath, then... tannic acid for 1 minute followed by immersion in a water bath, then immersing it for 1 minute in a...
Code of Federal Regulations, 2014 CFR
2014-01-01
... coloring, 40 parts water, 40 parts liquid detergent, and 40 parts oil of citronella, or other proprietary... dipping it in a solution of 0.0625 percent tannic acid, followed by immersion in a water bath, then... tannic acid for 1 minute followed by immersion in a water bath, then immersing it for 1 minute in a...
Code of Federal Regulations, 2012 CFR
2012-01-01
... coloring, 40 parts water, 40 parts liquid detergent, and 40 parts oil of citronella, or other proprietary... dipping it in a solution of 0.0625 percent tannic acid, followed by immersion in a water bath, then... tannic acid for 1 minute followed by immersion in a water bath, then immersing it for 1 minute in a...
Indoor radon levels in selected hot spring hotels in Guangdong, China.
Song, Gang; Zhang, Boyou; Wang, Xinming; Gong, Jingping; Chan, Daniel; Bernett, John; Lee, S C
2005-03-01
Guangdong is one of the provinces that have most hot springs in China, and many hotels have been set up near hot springs, with spring water introduced into the bath inside each hotel room for hot spring bathing to attract tourists. In the present study, we measured radon in indoor and outdoor air, as well as in hot spring waters, in four hot spring hotels in Guangdong by using NR-667A (III) continuous radon detector. Radon concentrations ranged 53.4-292.5 Bq L(-1) in the hot spring water and 17.2-190.9 Bq m(-3) in outdoor air. Soil gas intrusion, indoor hot spring water use and inefficient ventilation all contributed to the elevated indoor radon levels in the hotel rooms. From the variation of radon levels in closed unoccupied hotel rooms, soil gas intrusion was found to be a very important source of indoor radon in hotel rooms with floors in contact with soils. When there was spring water bathing in the bathes, average radon levels were 10.9-813% higher in the hotel rooms and 13.8-489% higher in bathes compared to their corresponding average levels when there was no spring water use. Spring water use in the hotel rooms had radon transfer coefficients from 1.6x10(-4) to 5.0x10(-3). Radon in some hotel rooms maintained in concentrations much higher than guideline levels might thus have potential health risks to the hotel workers, and technical and management measures should be taken to lower their exposure of radon through inhalation.
NASA Technical Reports Server (NTRS)
Hypes, W. D.; Batten, C. E.; Wilkins, J. R.
1974-01-01
Chemical/physical and microbiological characteristics are studied of typical bath and laundry waters collected during a 12 day test in which the untreated waste waters were reused for toilet flush. Most significant changes were found for ammonia, color, methylene blue active substances, phosphates, sodium, sulfates, total organic carbon, total solids, and turbidity in comparison with tap water baseline. The mean total number of microorganisms detected in the waste waters ranged from 1 million to 10 to the 7th power cells/m1 and the mean number of possible coliforms ranged from 10 to the 5th power to 1 million. An accumulation of particulates and an objectible odor were detected in the tankage used during the 12 day reuse of the untreated waste waters. The combined bath and laundry waste waters from a family of four provided 91 percent of the toilet flush water for the same family.
33 CFR 110.133 - Kennebec River in vicinity of Bath, Maine.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Kennebec River in vicinity of Bath, Maine. 110.133 Section 110.133 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY ANCHORAGES ANCHORAGE REGULATIONS Anchorage Grounds § 110.133 Kennebec River in vicinity...
33 CFR 110.133 - Kennebec River in vicinity of Bath, Maine.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 33 Navigation and Navigable Waters 1 2012-07-01 2012-07-01 false Kennebec River in vicinity of Bath, Maine. 110.133 Section 110.133 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY ANCHORAGES ANCHORAGE REGULATIONS Anchorage Grounds § 110.133 Kennebec River in vicinity...
33 CFR 110.133 - Kennebec River in vicinity of Bath, Maine.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 33 Navigation and Navigable Waters 1 2014-07-01 2014-07-01 false Kennebec River in vicinity of Bath, Maine. 110.133 Section 110.133 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY ANCHORAGES ANCHORAGE REGULATIONS Anchorage Grounds § 110.133 Kennebec River in vicinity...
NASA Astrophysics Data System (ADS)
Madonia, Alice; Bonamano, Simone; Caruso, Gabriella; Stefani', Chiara; Consalvi, Natalizia; Piermattei, Viviana; Zappalà, Giuseppe; Marcelli, Marco
2017-04-01
Coastal urban bathing areas are often affected by events of faecal contamination, caused by the discharge of untreated wastewaters during the bathing season that can increase the risk for public health. Monitoring the quality of recreational waters is still closely linked to time-consuming seawater sampling and laboratory analysis, not allowing promptly management interventions. To face this issue, the European environmental policies strongly promote the development of coastal observing systems, above all in the Southern European Seas (SES). Chromophoric Dissolved Organic Matter (CDOM) has been increasingly used as a tracer of bacterial loads, since wastewaters are characterized by a large amount of organic compounds. The aim of this work was to study the relation between CDOM and Escherichia coli abundance, giving relevance to bacterial physiological state detected using both the standard culture method and the innovative fluorescent antibody technique. Attention has been paid also on the expression of extracellular enzymatic activity by the total microbial community to explore the role of bacteria in the decomposition processes of dissolved organic matter. Data were collected during summer 2015 and 2016 in a bathing area of Civitavecchia at increasing distances from the discharge point. The results confirm the usefulness of CDOM measurements as a proxy of faecal pollution in bathing areas. In this perspective, the low-cost stand-alone systems equipped with CDOM fluorescence sensors developed by the Laboratory of Experimental Oceanology and Marine Ecology (Tuscia University) (Marcelli et al., 2014) could allow the continous monitoring of water quality, increasing the capabilities of the Civitavecchia Coastal Environmental Monitoring System (C-CEMS) in the analysis of pollution events. Thanks to the integration of in situ fixed stations, high-resolution satellites imagery and numerical models, C-CEMS provides a management tool to support the stakeholders for timely decision making (Bonamano et al., 2016).
1987-07-17
of some salts, mainly thiocyanate sodium. With wet spinning are used water/aqueous precipitation baths or organic coagulants (glycerin, hexanetriol ...comparatively small. During utilization of glycerine, isopropyl, butyl, hexanetriol baths into composition of bath for increasing elasticity of fiber...the number of C-atoms in the chain of their molecules. Therefore the glycerine bath is more than "rigid", than hexanetriol , whose effect/action is
Quantifying the Recreational Value of an Estuary: A Transferable Method
Coastal water quality impairment (excess bacteria and nutrients) due to failed septic systems and cesspools is a major concern for Cape Cod, Massachusetts because of its waters’ high economic and social value. High bacteria levels can lead to closures at bathing beaches. Nu...
A brain slice bath for physiology and compound microscopy, with dual-sided perifusion.
Heyward, P M
2010-12-01
Contemporary in vitro brain slice studies can employ compound microscopes to identify individual neurons or their processes for physiological recording or imaging. This requires that the bath used to maintain the tissue fits within the working distances of a water-dipping objective and microscope condenser. A common means of achieving this is to maintain thin tissue slices on the glass floor of a recording bath, exposing only one surface of the tissue to oxygenated bathing medium. Emerging evidence suggests that physiology can be compromised by this approach. Flowing medium past both sides of submerged brain slices is optimal, but recording baths utilizing this principle are not readily available for use on compound microscopes. This paper describes a tissue bath designed specifically for microscopy and physiological recording, in which temperature-controlled medium flows past both sides of the slices. A particular feature of this design is the use of concentric mesh rings to support and transport the live tissue without mechanical disturbance. The design is also easily adapted for use with thin acute slices, cultured slices, and acutely dispersed or cultured cells maintained either on cover slips or placed directly on the floor of the bath. The low profile of the bath provides a low angle of approach for electrodes, and allows use of standard condensers, nosepieces and water-dipping objective lenses. If visualization of individual neurons is not required, the bath can be mounted on a simple stand and used with a dissecting microscope. Heating is integral to the bath, and any temperature controller capable of driving a resistive load can be used. The bath is robust, readily constructed and requires minimal maintenance. Full construction and operation details are given. © 2010 The Author Journal of Microscopy © 2010 The Royal Microscopical Society.
Chronodiagnostic acquisition of recovery speed of heart rate under bathing stress.
Ishijima, M; Togawa, T
1999-11-01
Cycling on an ergometer is one effective means of measuring cardiovascular function while applying stress on the heart. Bathing in a hot water bath applies a low stress to the heart. The electrocardiograms of a healthy adult male (aged 35 at the start of study) were recorded while taking a hot water bath with no electrode attached to the body over a period of 2 years (376 days over a 762 day period). The recovery speed following the initial overshoot of the heart rate (HR) was observed. The bathtub was designed for the automatic acquisition of ECG data. Immediately after immersion in the tub, the HR reached a peak within 20 s and then exponentially decreased toward the lowest rate in the 120 s of bathing. The initial recovery speed of the HR from the stress of bathing had a specific rhythm in the subject. Spectrum analysis of the speed series indicated that slow recovery speed appeared in cyclic periods of approximately 1 year, 42 days and 17 days. The methodology may provide a chronodiagnostic index of an exercise test for cardiovascular function.
A case–control study of maternal bathing habits and risk for birth defects in offspring
2013-01-01
Background Nearly all women shower or take baths during early pregnancy; however, bathing habits (i.e., shower and bath length and frequency) may be related to the risk of maternal hyperthermia and exposure to water disinfection byproducts, both of which are suspected to increase risk for multiple types of birth defects. Thus, we assessed the relationships between bathing habits during pregnancy and the risk for several nonsyndromic birth defects in offspring. Methods Data for cases with one of 13 types of birth defects and controls from the National Birth Defects Prevention Study delivered during 2000–2007 were evaluated. Logistic regression analyses were conducted separately for each type of birth defect. Results There were few associations between shower frequency or bath frequency or length and risk for birth defects in offspring. The risk for gastroschisis in offspring was increased among women who reported showers lasting ≥15 compared to <15 minutes (adjusted odds ratio: 1.43, 95% confidence interval: 1.18-1.72). In addition, we observed modest increases in the risk for spina bifida, cleft lip with or without cleft palate, and limb reduction defects in offspring of women who showered ≥15 compared to <15 minutes. The results of comparisons among more specific categories of shower length (i.e., <15 minutes versus 15–19, 20–29, and ≥ 30 minutes) were similar. Conclusions Our findings suggest that shower length may be associated with gastroschisis, but the modest associations with other birth defects were not supported by analyses of bath length or bath or shower frequency. Given that showering for ≥15 minutes during pregnancy is very common, further evaluation of the relationship between maternal showering habits and birth defects in offspring is worthwhile. PMID:24131571
Fabrication of ZnO nanorod using spray-pyrolysis and chemical bath deposition method
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ramadhani, Muhammad F., E-mail: brian@tf.itb.ac.id; Pasaribu, Maruli A. H., E-mail: brian@tf.itb.ac.id; Yuliarto, Brian, E-mail: brian@tf.itb.ac.id
2014-02-24
ZnO thin films with nanorod structure were deposited using Ultrasonic Spray Pyrolysis method for seed growth, and Chemical Bath Deposition (CBD) for nanorod growth. High purity Zn-hydrate and Urea are used to control Ph were dissolved in ethanol and aqua bidest in Ultrasonic Spray Pyrolysis process. Glass substrate was placed above the heater plate of reaction chamber, and subsequently sprayed with the range duration of 5, 10 and 20 minutes at the temperatures of 3500 C. As for the Chemical Bath Deposition, the glass substrate with ZnO seed on the surface was immerse to Zn-hydrate, HMTA (Hexa Methylene Tetra Amine)more » and deionized water solution for duration of 3, 5 and 7 hour and temperatures of 600 C, washed in distilled water, dried, and annealed at 3500 C for an hour. The characterization of samples was carried out to reveal the surface morphology using Scanning Electron Microscopy (SEM). From the data, the combination of 5 minutes of Ultrasonic Spray Pyrolysis process and 3 hour of CBD has showed the best structure of nanorod. Meanwhile the longer Spraying process and CBD yield the bigger nanorod structure that have been made, and it makes the films more dense which make the nanorod collide each other and as a result produce unsymetric nanorod structure.« less
Factors affecting Escherichia coli concentrations at Lake Erie public bathing beaches
Francy, Donna S.; Darner, Robert A.
1998-01-01
The environmental and water-quality factors that affect concentrations of Escherichia coli (E. coli) in water and sediment were investigated at three public bathing beachesEdgewater Park, Villa Angela, and Sims Parkin the Cleveland, Ohio metropolitan area. This study was done to aid in the determination of safe recreational use and to help water- resource managers assess more quickly and accurately the degradation of recreational water quality. Water and lake-bottom sediments were collected and ancillary environmental data were compiled for 41 days from May through September 1997. Water samples were analyzed for E. coli concentrations, suspended sediment concentrations, and turbidity. Lake- bottom sediment samples from the beach area were analyzed for E. coli concentrations and percent dry weight. Concentrations of E. coli were higher and more variable at Sims Park than at Villa Angela or Edgewater Park; concentrations were lowest at Edgewater Park. Time-series plots showed that short-term storage (less than one week) of E. coli in lake-bottom sediments may have occurred, although no evidence for long-term storage was found during the sampling period. E. coli concentrations in water were found to increase with increasing wave height, but the resuspension of E. coli from lake-bottom sediments by wave action could not be adequately assessed; higherwave heights were often associated with the discharge of sewage containing E. coli during or after a rainfall and wastewater-treatment plant overflow. Multiple linear regression (MLR) was used to develop models to predict recreational water quality at the in water. The related variables included turbidity, antecedent rainfall, antecedent weighted rainfall, volumes of wastewater-treatment plant overflows and metered outfalls (composed of storm-water runoff and combined-sewer overflows), a resuspension index, and wave heights. For the beaches in this study, wind speed, wind direction, water temperature, and the prswimmers were not included in the model because they were shown to be statistically unrelated to E. coli concentrations. From the several models developed, one model was chosen that accounted for 58 percent of the variability in E. coli concentrations. The chosen MLR model contained weighted categorical rainfall, beach-specific turbidity, wave height, and terms to correct for the different magnitudes of E. coli concentrations among the three beaches. For 1997, the MLR model predicted the recreational water quality as well as, and in some cases better than, antecedent E. coli concentrations (the current method). The MLR model improved the sensitivity of the prediction and the percentage of correct predictions over the current method; however, the MLR model predictions still erred to a similar degree as the current method with regard to false negatives. A false negative would allow swimming when, in fact, the bathing water standard was exceeded. More work needs to be done to validate the MLR model with data collected during other recreational seasons, especially during a season with a greater frequency and intensity of summer rains. Studies could focus on adding to the MLR model other environmental and water-quality variables that improve the predictive ability of the model. These variables might include concentrations of E. coli in deeper sediments outside the bathing area, the direction of lake currents, site-specific-rainfall amounts, time-of-day information on overflows and metered outfalls, concentrations of E. coli in treated wastewater-treatment plant effluents, and occurrences of sewage-line breaks. Rapid biological or chemical methods for determination of recreational water quality could also be used as variables in model refinements. Possible methods include the use of experimental rapid assay methods for determination of E. coli concentrations or other fecal indicators and the use of chemical tracers for fecal contamination, such as coprostanol (a degradation
Acute whole-body cooling for exercise-induced hyperthermia: a systematic review.
McDermott, Brendon P; Casa, Douglas J; Ganio, Matthew S; Lopez, Rebecca M; Yeargin, Susan W; Armstrong, Lawrence E; Maresh, Carl M
2009-01-01
To assess existing original research addressing the efficiency of whole-body cooling modalities in the treatment of exertional hyperthermia. During April 2007, we searched MEDLINE, EMBASE, Scopus, SportDiscus, CINAHL, and Cochrane Reviews databases as well as ProQuest for theses and dissertations to identify research studies evaluating whole-body cooling treatments without limits. Key words were cooling, cryotherapy, water immersion, cold-water immersion, ice-water immersion, icing, fanning, bath, baths, cooling modality, heat illness, heat illnesses, exertional heatstroke, exertional heat stroke, heat exhaustion, hyperthermia, hyperthermic, hyperpyrexia, exercise, exertion, running, football, military, runners, marathoner, physical activity, marathoning, soccer, and tennis. Two independent reviewers graded each study on the Physiotherapy Evidence Database (PEDro) scale. Seven of 89 research articles met all inclusion criteria and a minimum score of 4 out of 10 on the PEDro scale. After an extensive and critical review of the available research on whole-body cooling for the treatment of exertional hyperthermia, we concluded that ice-water immersion provides the most efficient cooling. Further research comparing whole-body cooling modalities is needed to identify other acceptable means. When ice-water immersion is not possible, continual dousing with water combined with fanning the patient is an alternative method until more advanced cooling means can be used. Until future investigators identify other acceptable whole-body cooling modalities for exercise-induced hyperthermia, ice-water immersion and cold-water immersion are the methods proven to have the fastest cooling rates.
33 CFR 334.782 - SUPSHIP Bath Maine Detachment Mobile at AUSTAL, USA, Mobile, AL; restricted area.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 33 Navigation and Navigable Waters 3 2012-07-01 2012-07-01 false SUPSHIP Bath Maine Detachment... REGULATIONS § 334.782 SUPSHIP Bath Maine Detachment Mobile at AUSTAL, USA, Mobile, AL; restricted area. (a... local military or Naval authority, vessels of the United States Coast Guard, and local or state law...
33 CFR 334.782 - SUPSHIP Bath Maine Detachment Mobile at AUSTAL, USA, Mobile, AL; restricted area.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 33 Navigation and Navigable Waters 3 2011-07-01 2011-07-01 false SUPSHIP Bath Maine Detachment... REGULATIONS § 334.782 SUPSHIP Bath Maine Detachment Mobile at AUSTAL, USA, Mobile, AL; restricted area. (a... local military or Naval authority, vessels of the United States Coast Guard, and local or state law...
Northwest Manufacturing Initiative
2013-03-26
Testing of Metallic Materials] specifications. For high temperature tests, a heated water bath was use while for low temperature testing down to...Weld metal and heat affected zones were evaluated using Charpy and E399 fracture toughness methods. The influence of temperature , loading rate, CVN...determine the influence of fracture test methods and welding procedures on toughness. Room temperature E399 tests, (CTS) were carried out under
Balneotherapy in Treatment of Spastic Upper Limb after Stroke
Erceg-Rukavina, Tatjana; Stefanovski, Mihajlo
2015-01-01
Introduction: After stroke, spasticity is often the main problem that prevents functional recovery. Pain occurs in up to 70% of patients during the first year post-stroke. Materials and methods: A total of 70 patients (30 female and 45 male) mean age (65.67) participated in prospective, controlled study. Inclusion criteria: ischaemic stroke, developed spasticity of upper limb, post-stroke interval <6 months. Exclusion criteria: contraindications for balneotherapy and inability to follow commands. Experimental group (Ex) (n=35) was treated with sulphurous baths (31°-33°C) and controlled group (Co) with taped water baths, during 21 days. All patients were additionally treated with kinesitherapy and cryotherapy. The outcome was evaluated using Modified Ashworth scale for spasticity and VAS scale for pain. The significance value was sat at p<0.05. Goal: To find out the effects of balneotherapy with sulphurous bath on spasticity and pain in affected upper limb. Results: Reduction in tone of affected upper limb muscles was significant in Ex group (p<0.05). Pain decreased significantly in Ex-group (p<0.01). Conclusion: Our results show that balneotherapy with sulphurous water reduces spasticity and pain significantly and can help in treatment of post-stroke patients. PMID:25870474
L'vova, N V; Tupitsyna, Iu Iu; Badalov, N G; Krasnikov, V E; Lebedeva, O D
2013-01-01
The results of the study on the influence of carbon dioxide baths differing in the total mineralization levels on the clinical course of hypertensive disease associated with coronary heart disease and on various functional systems of the body. The data obtained provide an insight into the role of salt concentrations (10 and 20 g/l) in carbon dioxide bath water (1.2 g/l) applied for the traditional treatment of the patients with hypertensive disease associated with concomitant coronary heart disease and musculoskeletal pathology. Highly mineralized bath water has a greater influence on the functional state of the cardiovascular system by causing a more pronounced decrease in peripheral vascular resistance and hypotensive effect. Baths with a salt concentration of 20 g/l markedly reduced pain and had anti-inflammatory effect in the patients with pathology of support and locomotor organs.
The Total Exposure Model (TEM) uses deterministic and stochastic methods to estimate the exposure of a person performing daily activities of eating, drinking, showering, and bathing. There were 250 time histories generated, by subject with activities, for the three exposure ro...
Urban Sustainability and Public Health: Throwing the Bath Water Out and Not the Baby
NASA Technical Reports Server (NTRS)
Quattrochi, Dale A.
2009-01-01
This slide presentation reviews the affect of urbanization on community health. It exams urbanization trends in the Atlanta metro area and includes information on impervious surfaces, air quality, mitigation strategies, spatial growth modeling, land use, public health surveillance and different data collection methods.
Francy, Donna S.; Bertke, Erin E.; Finnegan, Dennis P.; Kephart, Christopher M.; Sheets, Rodney A.; Rhoades, John; Stumpe, Lester
2006-01-01
Source-tracking tools were used to identify potential sources of fecal contamination at two Lake Erie bathing beaches: an urban beach (Edgewater in Cleveland, Ohio) and a beach in a small city (Lakeshore in Ashtabula, Ohio). These tools included identifying spatial patterns of Escherichia coli (E. coli) concentrations in each area, determining weather patterns that caused elevated E. coli, and applying microbial source tracking (MST) techniques to specific sites. Three MST methods were used during this study: multiple antibiotic resistance (MAR) indexing of E. coli isolates and the presence of human-specific genetic markers within two types of bacteria, the genus Bacteroides and the species Enterococcus faecium. At Edgewater, sampling for E. coli was done during 2003-05 at bathing-area sites, at nearshore lake sites, and in shallow ground water in foreshore and backshore areas. Spatial sampling at nearshore lake sites showed that fecal contamination was most likely of local origin; E. coli concentrations near the mouths of rivers and outfalls remote to the beach were elevated (greater than 235 colony-forming units per 100 milliliters (CFU/100 mL)) but decreased along transport pathways to the beach. In addition, E. coli concentrations were generally highest in bathing-area samples collected at 1- and 2-foot water depths, midrange at 3-foot depths, and lowest in nearshore lake samples typically collected 150 feet from the shoreline. Elevated E. coli concentrations at bathing-area sites were generally associated with increased wave heights and rainfall, but not always. E. coli concentrations were often elevated in shallow ground-water samples, especially in samples collected less than 10 feet from the edge of water (near foreshore area). The interaction of shallow ground water and waves may be a mechanism of E. coli storage and accumulation in foreshore sands. Infiltration of bird feces through sand with surface water from rainfall and high waves may be concentrating E. coli in shallow ground water in foreshore and backshore sands. At Lakeshore, sampling for E. coli was done at bathing-area, nearshore lake, and parking-lot sites during 2004-05. Low concentrations of E. coli at nearshore lake sites furthest from the shoreline indicated that fecal contamination was most likely of local origin. High concentrations of E. coli in water and bed sediments at several nearshore lake sites showed that contamination was emanating from several points along the shoreline during wet and dry weather, including the boat ramp, an area near the pond drainage, and parking-lot sediments. Physical evidence confirmed that runoff from the parking lot leads to degradation of water quality at the beach. MST samples were collected to help interpret spatial findings and determine whether sources of fecal contamination were from wastewater or bird feces and if a human-specific marker was present. MAR indices were useful in distinguishing between bird feces and wastewater sources because they were about 10 times higher in the latter. The results from MAR indices agreed with results from the two human-specific markers in some but not all of the samples tested. Bacteroides and enterococci human-specific markers were found on one day at Edgewater and two days at Lakeshore. On three days at Edgewater and two days at Lakeshore, the MAR index indicated a mixed source, but neither marker was found in bathing-water samples; this may be because bacterial indicator concentrations were too low to detect a marker. Multiple tools are needed to help identify sources of fecal contamination at coastal beaches. Spatial sampling identified patterns in E. coli concentrations and yielded information on the physical pathways of contamination. MST methods provided information on whether the source was likely of human or nonhuman origin only; however, MST did not provide information on the pathways of contamination.
Mitchell, A.J.; Cole, Rebecca A.
2008-01-01
The faucet snail Bithynia tentaculata, a nonindigenous aquatic snail from Eurasia, was introduced into Lake Michigan in 1871 and has spread to the mid-Atlantic states, the Great Lakes region, Montana, and most recently, the Mississippi River. The faucet snail serves as intermediate host for several trematodes that have caused large-scale mortality among water birds, primarily in the Great Lakes region and Montana. It is important to limit the spread of the faucet snail; small fisheries equipment can serve as a method of snail distribution. Treatments with chemical disinfection, pH extremes, and heated water baths were tested to determine their effectiveness as a disinfectant for small fisheries equipment. Two treatments eliminated all test snails: (1) a 24-h exposure to Hydrothol 191 at a concentration of at least 20 mg/L and (2) a treatment with 50°C heated water for 1 min or longer. Faucet snails were highly resistant to ethanol, NaCl, formalin, Lysol, potassium permanganate, copper sulfate, Baquacil, Virkon, household bleach, and pH extremes (as low as 1 and as high as 13).
Figueras, M J; Inza, I; Polo, F; Guarro, J
1998-10-01
m-Enterococcus agar (m-Ent) has been generally considered the reference medium for faecal streptococci in bathing waters. However, it shows several shortcomings, and therefore it is important to test newly developed media that can guarantee more precise results. In this sense, the recently described oxolinic acid--esculin--azide agar medium (OAA) and m-enterococcus agar (m-Ent) were comparatively evaluated for the detection of faecal streptococci from seawater and fresh water. The OAA medium showed a significantly higher relative recovery percentage and specificity for both types of water than m-Ent. A similar spectrum of species was recorded from both media, Enterococcus faecium being predominant in fresh water and Enterococcus faecalis, in seawater. The superior performance of the OAA medium in both types of bathing waters, added to the fact that it does not require the use of complementary confirmative tests, makes this medium an excellent candidate to be employed for monitoring programmes.
Umbilical cord care in newborns
... the stump clean with gauze and water only. Sponge bathe the rest of your baby, as well. ... Neonatal care - umbilical cord Images Umbilical cord healing Sponge bath References Carlo WA, Ambalavanan N. The umbilicus. ...
Higgins, Trevor R; Climstein, Mike; Cameron, Melainie
2013-04-01
In team sports, a cycle of training, competition, and recovery occurs weekly during the competitive season. In this research, we evaluated hydrotherapy for recovery from a simulated game of rugby union tracked over a week of training. Twenty-four experienced male rugby union players (mean ± SD age 19.46 ± 0.82 years, weight 82.38 ± 11.12 kg, height 178.54 ± 5.75 cm) were randomly divided into 3 groups: cold water immersion (n = 8), contrast bath therapy (n = 8), and a control group (n = 8). The 2 forms of hydrotherapy were administered immediately after a simulated rugby game. Testing was conducted 1 hour before the game and at 5 intervals postgame: 1, 48, 72, 96, and 144 hours. Dependent variables included countermovement jump, 10- and 40-m sprints, sessional rating of perceived exertion (RPE), flexibility, thigh circumference, and self-reported delayed onset muscle soreness (DOMS). Significant differences in DOMS were found between the cold water immersion and contrast bath groups at 48 hours post intervention (p = 0.02), and between the control and contrast bath groups at 72 (p = 0.03) and 96 (p = 0.04) hours post intervention. Cold water immersion and contrast bath groups reported significantly different RPE at 72 hours (p = ?) and 96 hours post (p = 0.05) intervention. Athletes' perceptions of muscle soreness and sessional RPE scores for training were greater in the contrast bath group (20%) after the simulated game and throughout the training week. Although results from passive and power tests were inconclusive in determining whether cold water immersion or passive recovery was more effective in attenuating fatigue, results indicated contrast baths had little benefit in enhancing recovery during a cyclic week of rugby union.
Cercarial Dermatitis (Swimmer's Itch) FAQs
... the affected areas Bathe in Epsom salts or baking soda Soak in colloidal oatmeal baths Apply baking soda paste to the rash (made by stirring water into baking soda until it reaches a paste-like consistency) ...
Graczyk, Thaddeus K; Sunderland, Deirdre; Awantang, Grace N; Mashinski, Yessika; Lucy, Frances E; Graczyk, Zofi; Chomicz, Lidia; Breysse, Patrick N
2010-04-01
During summer months, samples of marine beach water were tested weekly for human waterborne pathogens in association with high and low bather numbers during weekends and weekdays, respectively. The numbers of bathers on weekends were significantly higher than on weekdays (P < 0.001), and this was associated with a significant (P < 0.04) increase in water turbidity. The proportion of water samples containing Cryptosporidium parvum, Giardia duodenalis, and Enterocytozoon bieneusi was significantly higher (P < 0.03) on weekends than on weekdays, and significantly (P < 0.01) correlated with enterococci counts. The concentration of all three waterborne pathogens was significantly correlated with bather density (P < 0.01). The study demonstrated that: (a) human pathogens were present in beach water on days deemed acceptable for bathing according to fecal bacterial standards; (b) enterococci count was a good indicator for the presence of Cryptosporidium, Giardia, and microsporidian spores in recreational marine beach water; (c) water should be tested for enterococci during times when bather numbers are high; (d) re-suspension of bottom sediments by bathers caused elevated levels of enterococci and waterborne parasites, thus bathers themselves can create a non-point source for water contamination; and (e) exposure to recreational bathing waters can play a role in epidemiology of microsporidiosis. In order to protect public health, it is recommended to: (a) prevent diapered children from entering beach water; (b) introduce bather number limits to recreational areas; (c) advise people with gastroenteritis to avoid bathing; and (d) use showers prior to and after bathing.
The oil-dispersion bath in anthroposophic medicine--an integrative review.
Büssing, Arndt; Cysarz, Dirk; Edelhäuser, Friedrich; Bornhöft, Gudrun; Matthiessen, Peter F; Ostermann, Thomas
2008-12-04
Anthroposophic medicine offers a variety of treatments, among others the oil-dispersion bath, developed in the 1930s by Werner Junge. Based on the phenomenon that oil and water do not mix and on recommendations of Rudolf Steiner, Junge developed a vortex mechanism which churns water and essential oils into a fine mist. The oil-covered droplets empty into a tub, where the patient immerses for 15-30 minutes. We review the current literature on oil-dispersion baths. The following databases were searched: Medline, Pubmed, Embase, AMED and CAMbase. The search terms were 'oil-dispersion bath' and 'oil bath', and their translations in German and French. An Internet search was also performed using Google Scholar, adding the search terms 'study' and 'case report' to the search terms above. Finally, we asked several experts for gray literature not listed in the above-mentioned databases. We included only articles which met the criterion of a clinical study or case report, and excluded theoretical contributions. Among several articles found in books, journals and other publications, we identified 1 prospective clinical study, 3 experimental studies (enrolling healthy individuals), 5 case reports, and 3 field-reports. In almost all cases, the studies described beneficial effects - although the methodological quality of most studies was weak. Main indications were internal/metabolic diseases and psychiatric/neurological disorders. Beyond the obvious beneficial effects of warm bathes on the subjective well-being, it remains to be clarified what the unique contribution of the distinct essential oils dispersed in the water can be. There is a lack of clinical studies exploring the efficacy of oil-dispersion baths. Such studies are recommended for the future.
Wither, A; Greaves, J; Dunhill, I; Wyer, M; Stapleton, C; Kay, D; Humphrey, N; Watkins, J; Francis, C; McDonald, A; Crowther, J
2005-01-01
Achieving compliance with the mandatory standards of the 1976 Bathing Water Directive (76/160/EEC) is required at all U.K. identified bathing waters. In recent years, the Fylde coast has been an area of significant investments in 'point source' control, which have not proven, in isolation, to satisfactorily achieve compliance with the mandatory, let alone the guide, levels of water quality in the Directive. The potential impact of riverine sources of pollution was first confirmed after a study in 1997. The completion of sewerage system enhancements offered the potential for the study of faecal indicator delivery from upstream sources comprising both point sources and diffuse agricultural sources. A research project to define these elements commenced in 2001. Initially, a desk study reported here, estimated the principal infrastructure contributions within the Ribble catchment. A second phase of this investigation has involved acquisition of empirical water quality and hydrological data from the catchment during the 2002 bathing season. These data have been used further to calibrate the 'budgets' and 'delivery' modelling and these data are still being analysed. This paper reports the initial desk study approach to faecal indicator budget estimation using available data from the sewerage infrastructure and catchment sources of faecal indicators.
Bougeard, M; Le Saux, J C; Jouan, M; Durand, G; Pommepuy, M
2010-01-01
The microbiological quality of waters in estuaries determines their acceptability for recreational uses. Microbiological contamination often results from urban wastewater discharges or non-point source pollution (manure spreading), and can cause bathing zones to be closed. European regulations (EC/7/2006) have proposed standards (500 E. coli/100 ml) for the acceptability areas for bathing. In this study, two models were associated to simulate contamination: SWAT on a catchment and MARS 2D in the downstream estuary. After river flow calibration and validation, two scenarios were simulated in SWAT, and E. coli fluxes obtained at the main outlet of the catchment were then introduced into MARS 2D to follow E. coli concentrations in the estuary. An annual evaluation of compliance to bathing area water quality standards was then calculated, linked with daily rainfall classes. Water quality in the estuary was below the standard on 13 days, including 5 days with rainfall superior to 10 mm, due to faecal contamination from soil leaching by rain, and 5 days with rainfall ranging from 0.1 to 5 mm/day, due to the high frequency of this level of rainfall. To conclude, this study allowed us to demonstrate the efficiency of models to gain a better understanding on water quality degradation factors.
Code of Federal Regulations, 2010 CFR
2010-01-01
... dipping it in a solution of 0.0625 percent tannic acid, followed by immersion in a water bath, then... tannic acid for 1 minute followed by immersion in a water bath, then immersing it for 1 minute in a... establishment: Crude carbolic acid; cresylic disinfectant; a formula consisting of 1 part FD&C green No. 3...
Code of Federal Regulations, 2011 CFR
2011-01-01
... dipping it in a solution of 0.0625 percent tannic acid, followed by immersion in a water bath, then... tannic acid for 1 minute followed by immersion in a water bath, then immersing it for 1 minute in a... establishment: Crude carbolic acid; cresylic disinfectant; a formula consisting of 1 part FD&C green No. 3...
75 FR 4618 - Office of Hazardous Materials Safety; Notice of Applications for Special Permit
Federal Register 2010, 2011, 2012, 2013, 2014
2010-01-28
... desired, include a self-addressed stamped postcard showing the special permit number. FOR FURTHER... lieu of the hot water bath test. (modes 1, 2, 3, 4, 5). 14954-N Zotos International, 49 CFR 173.306(a... lieu of the hot water bath test. (mode 1). 14956-N American Type Culture 49 CFR 173.196, 178.609 To...
Comparison of six extraction techniques for isolation of DNA from filamentous fungi.
van Burik, J A; Schreckhise, R W; White, T C; Bowden, R A; Myerson, D
1998-10-01
Filamentous fungi have a sturdy cell wall which is resistant to the usual DNA extraction procedures. We determined the DNA extraction procedure with the greatest yield of high quality fungal DNA and the least predilection for cross-contamination of equipment between specimens. Each of six extraction methods was performed using Aspergillus fumigatus hyphae. The six methods were: (1) glass bead pulverization with vortexing; (2) grinding with mortar and pestle followed by glass bead pulverization; (3) glass bead pulverization using 1% hydroxyacetyl trimethyl ammonium bromide (CTAB) buffer in a water bath sonicator; (4) water bath sonication in CTAB buffer; (5) grinding followed by incubation with CTAB; and (6) lyticase enzymatic cell lysis. Genomic DNA yields were measured by spectrophotometry and by visual reading of 2% agarose gels, with shearing assessed by the migration of the DNA on the gel. Genomic fungal DNA yields were highest for Method 1, followed by Methods 5 approximately = to 2 >3 approximately = to 4 approximately = to 6. Methods 2 and 5, both of which involved grinding with mortar and pestle, led to shearing of the genomic DNA in one of two trials each. We conclude that the use of glass beads with extended vortexing is optimal for extraction of microgramme amounts of DNA from filamentous fungal cultures.
Clinical and anti-aging effect of mud-bathing therapy for patients with fibromyalgia.
Maeda, Toyoki; Kudo, Yoshihiro; Horiuchi, Takahiko; Makino, Naoki
2017-12-06
Spa bathing is known as a medical treatment for certain diseases causing chronic pains. Spa water contains mineral components which lower the specific heat of the water, resulting in a higher efficiency to warm body-core temperature. This phenomenon yields pain-relieving effect for rheumatoid arthritis, low back pain, sciatic neuralgia, fibromyalgia, etc. Here we introduce medical and biological effects of mud-spa-bathing therapy for fibromyalgia other than pain relief, the changes of blood examination data, and the telomere length of circulating leukocytes. The enrolled 7 patients with fibromyalgia syndrome were hospitalized and were subject to daily mud bathing at 40 °C for 10 min for about a month. Then, their subjective pain was reduced to about a quarter in average. They also showed lowered serum triglyceride and C-reactive protein level, maintaining the levels of aspartate transaminase and creatine phosphokinase, and increases of the red blood cell count, the serum albumin level, and the serum LDL-cholesterol level in comparison with cases without mud-bathing therapy, suggesting that mud bathing prevents inflammation and muscle atrophy and improves nutritional condition in fibromyalgia. In addition, the analysis of telomere length of peripheral leukocytes revealed a trend of negative correlation between telomere shortening and laboratory data change of hemoglobin and serum albumin. These telomeric changes can be explained hypothetically by an effect of mud bathing extending life-span of circulating leukocytes.
Klemenkov, S V; Davydova, O B; Levitskiĭ, E F; Chashchin, N F; Sharova, O Ia; Kubushko, I V
1999-01-01
73 patients with ischemic heart disease (IHD) and stable angina pectoris of NYHA class I and II underwent balneotherapy. 43 of them took a course of sodium chloride baths, 30 control patients took common water baths. As shown by spiroveloergometry and Holter monitoring, sodium chloride baths are a good training modality in IHD patients. They enhance muscular performance and coronary heart reserve, reduce the mean 24-h number of ventricular extrasystoles by 49.9%, supraventricular extrasystoles by 57.5%.
The effectiveness of cooling conditions on temperature of canine EDTA whole blood samples
Sun, Xiaocun; Flatland, Bente
2016-01-01
Background Preanalytic factors such as time and temperature can have significant effects on laboratory test results. For example, ammonium concentration will increase 31% in blood samples stored at room temperature for 30 min before centrifugation. To reduce preanalytic error, blood samples may be placed in precooled tubes and chilled on ice or in ice water baths; however, the effectiveness of these modalities in cooling blood samples has not been formally evaluated. The purpose of this study was to evaluate the effectiveness of various cooling modalities on reducing temperature of EDTA whole blood samples. Methods Pooled samples of canine EDTA whole blood were divided into two aliquots. Saline was added to one aliquot to produce a packed cell volume (PCV) of 40% and to the second aliquot to produce a PCV of 20% (simulated anemia). Thirty samples from each aliquot were warmed to 37.7 °C and cooled in 2 ml allotments under one of three conditions: in ice, in ice after transfer to a precooled tube, or in an ice water bath. Temperature of each sample was recorded at one minute intervals for 15 min. Results Within treatment conditions, sample PCV had no significant effect on cooling. Cooling in ice water was significantly faster than cooling in ice only or transferring the sample to a precooled tube and cooling it on ice. Mean temperature of samples cooled in ice water was significantly lower at 15 min than mean temperatures of those cooled in ice, whether or not the tube was precooled. By 4 min, samples cooled in an ice water bath had reached mean temperatures less than 4 °C (refrigeration temperature), while samples cooled in other conditions remained above 4.0 °C for at least 11 min. For samples with a PCV of 40%, precooling the tube had no significant effect on rate of cooling on ice. For samples with a PCV of 20%, transfer to a precooled tube resulted in a significantly faster rate of cooling than direct placement of the warmed tube onto ice. Discussion Canine EDTA whole blood samples cool most rapidly and to a greater degree when placed in an ice-water bath rather than in ice. Samples stored on ice water can rapidly drop below normal refrigeration temperatures; this should be taken into consideration when using this cooling modality. PMID:27917319
Valizadeh, Leila; Seyyedrasooli, Alehe; Zamanazadeh, Vahid; Nasiri, Khadijeh
2015-01-01
Background: Sleep disorders are common mental disorders reported among the elderly in all countries, and with nonpharmacological interventions, they could be helped to improve their sleep quality. Objectives: The aim of this study was to compare the effects of two interventions, foot reflexology and foot bath, on sleep quality in elderly people. Patients and Methods: This three-group randomized clinical trial (two experimental groups and a control group) was conducted on 69 elderly men. The two experimental groups had reflexology (n = 23) and foot bath (n = 23) interventions for 6 weeks. The reflexology intervention was done in the mornings, once a week for ten minutes on each foot. The participants in the foot bath group were asked to soak their feet in 41°C to 42°C water one hour before sleeping. The pittsburgh sleep quality index (PSQI) was completed before and after the intervention through an interview process. Results: The results showed that the PSQI scores after intervention compared to before it in the reflexology and foot bath groups were statistically significant (P = 0.01 , P = 0.001); however, in the control group did not show a statistically significant difference (P = 0.14). In addition, the total score changes among the three groups were statistically significant (P = 0.01). Comparing the score changes of quality of sleep between the reflexology and foot bath groups showed that there was no significant difference in none of the components and the total score (P = 0.09). The two interventions had the same impact on the quality of sleep. Conclusions: It is suggested that the training of nonpharmacological methods to improve sleep quality such as reflexology and foot bath be included in the elderly health programs. In addition, it is recommended that the impact of these interventions on subjective sleep quality using polysomnographic recordings be explored in future research. PMID:26734475
Regenerating using aqueous cleaners with ozone and electrolysis
NASA Technical Reports Server (NTRS)
Mcginness, Michael P.
1994-01-01
A new process converts organic oil and grease contaminates in used water based cleaners into synthetic surfactants. This permits the continued use of a cleaning solution long after it would have been dumped using previously known methods. Since the organic soils are converted from contaminates to cleaning compounds the need for frequent bath dumps is totally eliminated. When cleaning solutions used in aqueous cleaning systems are exhausted and ready for disposal, they will always contain the contaminates removed from the cleaned parts and drag-in from prior cleaning steps. Even when the cleaner is biodegradable these contaminants will frequently cause the waste cleaning solution to be a hazardous waste. Chlorinated solvents are rapidly being replaced by aqueous cleaners to avoid the new ozone-depletion product-labeling-law. Many industry standard halocarbon based solvents are being completely phased out of production, and their prices have nearly tripled. Waste disposal costs and cradle-to-grave liability are also major concerns for industry today. This new process reduces the amount of water and chemicals needed to maintain the cleaning process. The cost of waste disposal is eliminated because the water and cleaning compounds are reused. Energy savings result by eliminating the need for energy currently used to produce and deliver fresh water and chemicals as well as the energy used to treat and destroy the waste from the existing cleaning processes. This process also allows the cleaning bath to be maintained at the peak performance of a new bath resulting in decreased cycle times and decreased energy consumption needed to clean the parts. This results in a more efficient and cost effective cleaning process.
NASA Astrophysics Data System (ADS)
Lee, Soomin; Fujimura, Hiroko; Shimomura, Yoshihiro; Katsuura, Tetsuo
2015-09-01
Recently, a growing number in Japan are switching to taking baths in the morning (morning bathing). However, the effects of the morning bathing on human physiological functions and work efficiency have not yet been revealed. Then, we hypothesized that the effect of morning bathing on physiological functions would be different from those of night bathing. In this study, we measured the physiological functions and work efficiency during the day following the morning bathing (7:10-7:20) including showering, mist sauna bathing, and no bathing as a control. Ten male healthy young adults participated in this study as the subjects. We evaluated the rectal temperature (Tre), skin temperature (Tsk), heart rate (HR), heart rate variability (HRV), blood pressure (BP), the relative power density of the alpha wave (α-wave ratio) of electroencephalogram, alpha attenuation coefficient (AAC), and the error rate of the task performance. As a result, we found that the HR after the mist sauna bathing was significantly lower than those after no bathing rest 3 (11:00). Furthermore, we verified that the α-wave ratio of the Pz after the mist sauna bathing was significantly lower than those after no bathing during the task 6 (15:00). On the other hand, the α-wave ratio of the Pz after the mist sauna bathing was significantly higher than those after showering during the rest 3 (11:00). Tsk after the mist sauna bathing was higher than those after the showering at 9:00 and 15:00. In addition, the error rate of the task performance after the mist sauna bathing was lower than those after no bathing and showering at 14:00. This study concludes that a morning mist sauna is safe and maintains both skin temperature compared to other bathing methods. Moreover, it is presumed that the morning mist sauna bathing improves work efficiency comparing other bathing methods during the task period of the day following the morning bathing.
Lee, Soomin; Fujimura, Hiroko; Shimomura, Yoshihiro; Katsuura, Tetsuo
2015-09-01
Recently, a growing number in Japan are switching to taking baths in the morning (morning bathing). However, the effects of the morning bathing on human physiological functions and work efficiency have not yet been revealed. Then, we hypothesized that the effect of morning bathing on physiological functions would be different from those of night bathing. In this study, we measured the physiological functions and work efficiency during the day following the morning bathing (7:10-7:20) including showering, mist sauna bathing, and no bathing as a control. Ten male healthy young adults participated in this study as the subjects. We evaluated the rectal temperature (Tre), skin temperature (Tsk), heart rate (HR), heart rate variability (HRV), blood pressure (BP), the relative power density of the alpha wave (α-wave ratio) of electroencephalogram, alpha attenuation coefficient (AAC), and the error rate of the task performance. As a result, we found that the HR after the mist sauna bathing was significantly lower than those after no bathing rest 3 (11:00). Furthermore, we verified that the α-wave ratio of the Pz after the mist sauna bathing was significantly lower than those after no bathing during the task 6 (15:00). On the other hand, the α-wave ratio of the Pz after the mist sauna bathing was significantly higher than those after showering during the rest 3 (11:00). Tsk after the mist sauna bathing was higher than those after the showering at 9:00 and 15:00. In addition, the error rate of the task performance after the mist sauna bathing was lower than those after no bathing and showering at 14:00. This study concludes that a morning mist sauna is safe and maintains both skin temperature compared to other bathing methods. Moreover, it is presumed that the morning mist sauna bathing improves work efficiency comparing other bathing methods during the task period of the day following the morning bathing.
Long, Blaine C; Jutte, Lisa S; Knight, Kenneth L
2010-01-01
Thermocouples and electrothermometers are used in therapeutic modality research. Until recently, researchers assumed that these instruments were valid and reliable. To examine 3 different thermocouple types in 5 degrees C, 15 degrees C, 18.4 degrees C, 25 degrees C, and 35 degrees C water baths. Randomized controlled trial. Therapeutic modality laboratory. Eighteen thermocouple leads were inserted through the wall of a foamed polystyrene cooler. The cooler was filled with water. Six thermocouples (2 of each model) were plugged into the 6 channels of the Datalogger and 6 randomly selected channels in the 2 Iso-Thermexes. A mercury thermometer was immersed into the water and was read every 10 seconds for 4 minutes during each of 6 trials. The entire process was repeated for each of 5 water bath temperatures (5 degrees C, 15 degrees C, 18.4 degrees C, 25 degrees C, 35 degrees C). Temperature and absolute temperature differences among 3 thermocouple types (IT-21, IT-18, PT-6) and 3 electrothermometers (Datalogger, Iso-Thermex calibrated from -50 degrees C to 50 degrees C, Iso-Thermex calibrated from -20 degrees C to 80 degrees C). Validity and reliability were dependent on thermocouple type, electrothermometer, and water bath temperature (P < .001; modified Levene P < .05). Statistically, the IT-18 and PT-6 thermocouples were not reliable in each electrothermometer; however, these differences were not practically different from each other. The PT-6 thermocouples were more valid than the IT-18s, and both thermocouple types were more valid than the IT-21s, regardless of water bath temperature (P < .001). The validity and reliability of thermocouples interfaced to an electrothermometer under experimental conditions should be tested before data collection. We also recommend that investigators report the validity, the reliability, and the calculated uncertainty (validity + reliability) of their temperature measurements for therapeutic modalities research. With this information, investigators and clinicians will be better able to interpret and compare results and conclusions.
Willerding, Linus; Limmer, Simone; Hossann, Martin; Zengerle, Anja; Wachholz, Kirsten; Ten Hagen, Timo L M; Koning, Gerben A; Sroka, Ronald; Lindner, Lars H; Peller, Michael
2016-01-28
Systemic chemotherapy of solid tumors could be enhanced by local hyperthermia (HT) in combination with thermosensitive liposomes (TSL) as drug carriers. In such an approach, effective HT of the tumor is considered essential for successful triggering local drug release and targeting of the drug to the tumor. To investigate the effect of HT method on the effectiveness of drug delivery, a novel laser-based HT device designed for the use in magnetic resonance imaging (MRI) was compared systematically with the frequently used cold light lamp and water bath HT. Long circulating phosphatidyldiglycerol-based TSL (DPPG2-TSL) with encapsulated doxorubicin (DOX) were used as drug carrier enabling intravascular drug release. Experiments were performed in male Brown Norway rats with a syngeneic soft tissue sarcoma (BN 175) located on both hind legs. One tumor was heated while the second tumor remained unheated as a reference. Six animals were investigated per HT method. DPPG2-TSL were injected i.v. at a stable tumor temperature above 40°C. Thereafter, temperature was maintained for 60min. Total DOX concentration in plasma, tumor tissue and muscle was determined post therapy by HPLC. Finally, the new laser-based device was tested in a MRI environment at 3T using DPPG2-TSL with encapsulated Gd-based contrast agent. All methods showed effective DOX delivery by TSL with 4.5-23.1ng/mg found in the heated tumors. In contrast, DOX concentration in the non-heated tumors was 0.5±0.1ng/mg. Independent of used HT methods, higher DOX levels were found in the smaller tumors. In comparison water bath induced lowest DOX delivery but still showing fourfold higher DOX concentrations compared to the non-heated tumors. With the laser-based applicator, a 13 fold higher DOX deposition was possible for large tumors and a 15 fold higher for the small tumors, respectively. Temperature gradients in the tumor tissue were higher with the laser and cold light lamp (-0.3°C/mm to -0.5°C/mm) compared to the water bath (-0.1°C/mm and -0.2°C/mm). Visualization of HT in the MRI demonstrated successful localized heating throughout the entire tumor volume by contrast agent release from DPPG2-TSL. In conclusion, HT triggered drug delivery by using DPPG2-TSL is a promising tool in chemotherapy but effectiveness markedly depended on the method of heating and also on tumor size. Local HT using a cold light lamp or the new laser applicator allowed more efficient drug delivery than using a regional water bath heating. MR-compatibility of the new applicator gives the opportunity for future experiments investing drug delivery in more detail by MRI at low technical efforts. Copyright © 2015 Elsevier B.V. All rights reserved.
Socioeconomic status and exposure to disinfection by-products in drinking water in Spain.
Castaño-Vinyals, Gemma; Cantor, Kenneth P; Villanueva, Cristina M; Tardon, Adonina; Garcia-Closas, Reina; Serra, Consol; Carrato, Alfredo; Malats, Núria; Rothman, Nathaniel; Silverman, Debra; Kogevinas, Manolis
2011-03-16
Disinfection by-products in drinking water are chemical contaminants that have been associated with cancer and other adverse effects. Exposure occurs from consumption of tap water, inhalation and dermal absorption. We determined the relationship between socioeconomic status and exposure to disinfection by-products in 1271 controls from a multicentric bladder cancer case-control study in Spain. Information on lifetime drinking water sources, swimming pool attendance, showering-bathing practices, and socioeconomic status (education, income) was collected through personal interviews. The most highly educated subjects consumed less tap water (57%) and more bottled water (33%) than illiterate subjects (69% and 17% respectively, p-value = 0.003). These differences became wider in recent time periods. The time spent bathing or showering was positively correlated with attained educational level (p < 0.001). Swimming pool attendance was more frequent among highly educated subjects compared to the illiterate (odds ratio = 3.4; 95% confidence interval 1.6-7.3). The most highly educated subjects were less exposed to chlorination by-products through ingestion but more exposed through dermal contact and inhalation in pools and showers/baths. Health risk perceptions and economic capacity may affect patterns of water consumption that can result in differences in exposure to water contaminants.
NASA Astrophysics Data System (ADS)
Iwase, Satoshi; Kawahara, Yuko; Nishimura, Naoki; Sugenoya, Junichi
2016-05-01
To examine the effects of micro mist sauna bathing, produced by water crushing method, we exposed ten male subjects to five cases of micro mist sauna, namely (1) room temperature (RT) 38 °C with 100 % (actually 91 %) relative humidity (RH), (2) RT 41.5 °C with 80 % (actually 81 %) RH, (3) RT 41.5 °C with 100 % (actually 96 %) RH, (4) RT 45.0 °C with 64 % (actually 61 %) RH, and (5) RT 45.0 °C with 100 % (actually 86 %) RH, and measured tympanic temperature, mean skin temperature, heart rate (HR), and cheek moisture content, as well as ratings of thermal and sweating sensation tympanic temperatures at RT 45 °C were significantly higher at 86 % RH than those at 61 % RH; however, those at RT 45 °C with 61 % RH were higher than those with 86 % RH during recovery. There were no significant differences at RT 41.5 °C between with 81 % RH and with 96 % RH. Mean skin temperature was the highest at RT 45 °C 86 % RH case, followed by at RT 41.5 °C 96 % RH, RT 45 °C 61 % RH, RT 41.5 °C 81 % RH, and finally at RT 38 °C 91 % RH. HR change showed the same order as for mean skin temperature. A significant difference in cheek moisture content was observed between RT 41.5 °C with 81 % RH and RT 45 °C with 86 % RH 10 min after the micro mist bathing. There were no significant differences between ratings of thermal sensation at RT 41.5 °C with 81 % RH and at RT 45 °C with 61 % RH and RT 45 °C with 61 % RH and RT 45 °C with 86 % RH. Between RT 45 °C with 86 % RH and RT 41.5 °C with 81 % RH, there was a tendency for interaction (0.05 < p < 0.1). Other cases showed significant higher ratings of thermal sensation at higher room temperature or higher relative humidity. The ratings of sweating sensation 10 min after the mist sauna bathing were significantly higher at higher RT and RH except between RT 41.5 °C 96 % RH and RT 45 °C 86 % RH which exhibited no significant difference. We concluded that the micro mist sauna produced by water crushing method induced more moderate and effective thermal effect during micro mist sauna bathing than the conventional mist sauna bathing. In addition, micro mist sauna is as effective for heating the human subjects as bathtub bathing as well as more moderate thermal and sweating sensations.
Francy, Donna S.; Gifford, Amie M.; Darner, Robert A.
2003-01-01
Results of studies during the recreational seasons of 2000 and 2001 strengthen the science that supports monitoring of our Nation?s beaches. Water and sediment samples were collected and analyzed for concentrations of Escherichia coli (E. coli). Ancillary water-quality and environmental data were collected or compiled to determine their relation to E. coli concentrations. Data were collected at three Lake Erie urban beaches (Edgewater, Villa Angela, and Huntington), two Lake Erie beaches in a less populated area (Mentor Headlands and Fairport Harbor), and one inland-lake beach (Mosquito Lake). The distribution of E. coli in water and sediments within the bathing area, outside the bathing area, and near the swash zone was investigated at the three Lake Erie urban beaches and at Mosquito Lake. (The swash zone is the zone that is alternately covered and exposed by waves.) Lake-bottom sediments from outside the bathing area were not significant deposition areas for E. coli. In contrast, interstitial water and subsurface sediments from near the swash zone were enriched with E. coli. For example, E. coli concentrations were as high as 100,000 colonies per 100 milliliters in some interstitial waters. Although there are no standards for E. coli in swash-zone materials, the high concentrations found at some locations warrant concern for public health. Studies were done at Mosquito Lake to identify sources of fecal contamination to the lake and bathing beach. Escherichia coli concentrations decreased with distance from a suspected source of fecal contamination that is north of the beach but increased at the bathing beach. This evidence indicated that elevated E. coli concentrations at the bathing beach are of local origin rather than from transport of bacteria from sites to the north. Samples collected from the three Lake Erie urban beaches and Mosquito Lake were analyzed to determine whether wastewater indicators could be used as surrogates for E. coli at bathing beaches. None of the concentrations of wastewater indicators of fecal contamination, including 3b-coprostanol and cholesterol, were significantly correlated (a=0.05) to concentrations of E. coli. Concentrations of the two compounds that were significantly correlated to E. coli were components of coal tar and asphalt, which are not necessarily indicative of fecal contamination. Data were collected to build on an earlier 1997 study to develop and test multiple-linear-regression models to predict E. coli concentrations using water-quality and environmental variables as explanatory variables. The probability of exceeding the single-sample bathing-water standard for E. coli (235 colonies per 100 milliliters) was used as the model output variable. Threshold probabilities for each model were established. Computed probabilities that are less than a threshold probability indicate that bacterial water quality is most likely acceptable. Computed probabilities equal to or above the threshold probability indicate that the water quality is most likely not acceptable and that a water-quality advisory may be needed. Models were developed at each beach, whenever possible, using combinations of 1997, 2000, and (or) 2001 data. The models developed and tested in this study were shown to be beach specific; that is, different explanatory variables were used to predict the probability of exceeding the standard at each beach. At Mentor Headlands and Fairport Harbor, models were not developed because water quality was generally good. At the three Lake Erie urban beaches, models were developed with variable lists that included the number of birds on the beach at the time of sampling, lake-current direction, wave height, turbidity, streamflow of a nearby river, and rainfall. The models for Huntington explained a larger percentage of the variability in E. coli concentrations than the models for Edgewater and Villa Angela. At Mosquito Lake, a model based on 2000 and 2001 data contained the
NASA Astrophysics Data System (ADS)
Shui, Lang; Cui, Zhixiang; Ma, Xiaodong; Jiang, Xu; Chen, Mao; Xiang, Yong; Zhao, Baojun
2018-05-01
The bottom-blown copper smelting furnace is a novel copper smelter developed in recent years. Many advantages of this furnace have been found, related to bath mixing behavior under its specific gas injection scheme. This study aims to use an oil-water double-phased laboratory-scale model to investigate the impact of industry-adjustable variables on bath mixing time, including lower layer thickness, gas flow rate, upper layer thickness and upper layer viscosity. Based on experimental results, an overall empirical relationship of mixing time in terms of these variables has been correlated, which provides the methodology for industry to optimize mass transfer in the furnace.
Lavender, Tina; Bedwell, Carol; Roberts, Stephen A; Hart, Anna; Turner, Mark A; Carter, Lesley-Anne; Cork, Michael J
2013-01-01
To examine the hypothesis that the use of a wash product formulated for newborn (<1 month of age) bathing is not inferior (no worse) to bathing with water only. Assessor-blinded, randomized, controlled, noninferiority trial. A teaching hospital in the Northwest of England and in participants' homes. Three-hundred-and-seven healthy, term infants recruited within 48 hours of birth. We compared bathing with a wash product (n = 159) to bathing with water alone (n = 148). The primary outcome was transepidermal water loss (TEWL) at 14 days postbirth; the predefined difference deemed to be unimportant was 1.2. Secondary outcomes comprised changes in stratum corneum hydration, skin surface pH, clinical observations of the skin, and maternal views. Complete TEWL data were obtained for 242 (78.8%) infants. Wash was noninferior to water alone in terms of TEWL (intention-to-treat analysis: 95% confidence interval [CI] for difference [wash-water, adjusted for family history of eczema, neonate state, and baseline] -1.24, 1.07; per protocol analysis: 95% CI -1.42, 1.09). No significant differences were found in secondary outcomes. We were unable to detect any differences between the newborn wash product and water. These findings provide reassurance to parents who choose to use the test newborn wash product or other technically equivalent cleansers and provide the evidence for health care professionals to support parental choice. © 2013 AWHONN, the Association of Women's Health, Obstetric and Neonatal Nurses.
Risk Levels of Toxic Cyanobacteria in Portuguese Recreational Freshwaters
Menezes, Carina; Dias, Elsa
2017-01-01
Portuguese freshwater reservoirs are important socio-economic resources, namely for recreational use. National legislation concerning bathing waters does not include mandatory levels or guidelines for cyanobacteria and cyanotoxins. This is an issue of concern since cyanotoxin-based evidence is insufficient to change the law, and the collection of scientific evidence has been hampered by the lack of regulatory levels for cyanotoxins in bathing waters. In this work, we evaluate the profile of cyanobacteria and microcystins (MC) in eight freshwater reservoirs from the center of Portugal, used for bathing/recreation, in order to determine the risk levels concerning toxic cyanobacteria occurrence. Three of the reservoirs did not pose a risk of MC contamination. However, two reservoirs presented a high risk in 7% of the samples according to the World Health Organization (WHO) guidelines for MC in bathing waters (above 20 µg/L). In the remaining three reservoirs, the risk concerning microcystins occurrence was low. However, they exhibited recurrent blooms and persistent contamination with MC up to 4 µg/L. Thus, the risk of exposure to MC and potential acute and/or chronic health outcomes should not be disregarded in these reservoirs. These results contribute to characterize the cyanobacterial blooms profile and to map the risk of toxic cyanobacteria and microcystins occurrence in Portuguese inland waters. PMID:29057822
Environmental geology of Bath, England
NASA Astrophysics Data System (ADS)
Kellaway, G. A.
1995-10-01
The hot springs of Bath, England, have been of importance to man for hundreds of years. It was a famous spa in Roman times. Subsequently, the springs were used during the 17th through the 20th centuries and extensive urban and commercial properties were developed at Bath using the water for medical and tourist-oriented activities. With urban and commercial development in the area, man's impact on the environment was substantial and typical environmental problems included pollution, land subsidence, or stability that effected construction, drainage, highways, and canals. During the growth of Bath in the 18th and 19th centuries these environmental problems were described by geologist William Smith and Joseph Townsend. Bath and vicinity provides a unique example of environmental geoscience.
Microbiological Analysis in Three Diverse Natural Geothermal Bathing Pools in Iceland
Thorolfsdottir, Berglind Osk Th.; Marteinsson, Viggo Thor
2013-01-01
Natural thermal bathing pools contain geothermal water that is very popular to bathe in but the water is not sterilized, irradiated or treated in any way. Increasing tourism in Iceland will lead to increasing numbers of bath guests, which can in turn affect the microbial flora in the pools and therefore user safety. Today, there is no legislation that applies to natural geothermal pools in Iceland, as the water is not used for consumption and the pools are not defined as public swimming pools. In this study, we conducted a microbiological analysis on three popular but different natural pools in Iceland, located at Lýsuhóll, Hveravellir and Landmannalaugar. Total bacterial counts were performed by flow cytometry, and with plate count at 22 °C, 37 °C and 50 °C. The presence of viable coliforms, Enterococcus spp. and pseudomonads were investigated by growth experiments on selective media. All samples were screened for noroviruses by real time PCR. The results indicate higher fecal contamination in the geothermal pools where the geothermal water flow was low and bathing guest count was high during the day. The number of cultivated Pseudomonas spp. was high (13,000–40,000 cfu/100 mL) in the natural pools, and several strains were isolated and classified as opportunistic pathogens. Norovirus was not detected in the three pools. DNA was extracted from one-liter samples in each pool and analyzed by partial 16S rRNA gene sequencing. Microbial diversity analysis revealed different microbial communities between the pools and they were primarily composed of alpha-, beta- and gammaproteobacteria. PMID:23493033
Bath Iron Works, CWA-01-2018-0033; EPCRA-01-2018-0034
Notice of Proposed Assessment of Class II Civil Penalty and Notice of Opportunity for a Hearing under Sections 309(g) of the Clean Water Act (CWA) for Bath Iron Works, CWA-01-2018-0033; EPCRA-01-2018-0034
Poberskaia, V A; Dement'eva, O I
1997-01-01
Children exposed to low-dose radiation are often treated in sanatoria with mineral baths. Of the latter balneoprocedures widely practiced are sodium chloride (SC) baths with mineralization 20-30 g/l. Mineralization 40 g/l is less frequently used. To specify changes in the function of cardiovascular system induced by SC baths of different concentration (40 versus 20 g/l) 131 senior schoolchildren exposed to low-dose radiation or other environmental pollutants were examined both after a single balneological procedure and after the course treatment (maximum 10 procedures). The baths lasted 8-15 min at water temperature 36-38 OC in a day intervals. The response was assessed by ECG, tetrapolar chest rheography, bicycle exercise. All the children had cardiovascular disorders of non-rheumatic origin. Therapeutic effect was more pronounced after baths with SC concentration 40 g/l. These baths are recommended for improvement of vegetative regulation of the heart, correction of hemodynamic defects. Baths with mineralization 20 g/l are better in upgrading function of the autonomic nervous system.
Carbonate ion-enriched hot spring water promotes skin wound healing in nude rats.
Liang, Jingyan; Kang, Dedong; Wang, Yingge; Yu, Ying; Fan, Jianglin; Takashi, En
2015-01-01
Hot spring or hot spa bathing (Onsen) is a traditional therapy for the treatment of certain ailments. There is a common belief that hot spring bathing has therapeutic effects for wound healing, yet the underlying molecular mechanisms remain unclear. To examine this hypothesis, we investigated the effects of Nagano hot spring water (rich in carbonate ion, 42°C) on the healing process of the skin using a nude rat skin wound model. We found that hot spring bathing led to an enhanced healing speed compared to both the unbathed and hot-water (42°C) control groups. Histologically, the hot spring water group showed increased vessel density and reduced inflammatory cells in the granulation tissue of the wound area. Real-time RT-PCR analysis along with zymography revealed that the wound area of the hot spring water group exhibited a higher expression of matrix metalloproteinases-2 and -9 compared to the two other control groups. Furthermore, we found that the enhanced wound healing process induced by the carbonate ion-enriched hot spring water was mediated by thermal insulation and moisture maintenance. Our results provide the evidence that carbonate ion-enriched hot spring water is beneficial for the treatment of skin wounds.
CFD Modeling of Swirl and Nonswirl Gas Injections into Liquid Baths Using Top Submerged Lances
NASA Astrophysics Data System (ADS)
Huda, Nazmul; Naser, J.; Brooks, G.; Reuter, M. A.; Matusewicz, R. W.
2010-02-01
Fluid flow phenomena in a cylindrical bath stirred by a top submerged lance (TSL) gas injection was investigated by using the computational fluid dynamic (CFD) modeling technique for an isothermal air-water system. The multiphase flow simulation, based on the Euler-Euler approach, elucidated the effect of swirl and nonswirl flow inside the bath. The effects of the lance submergence level and the air flow rate also were investigated. The simulation results for the velocity fields and the generation of turbulence in the bath were validated against existing experimental data from the previous water model experimental study by Morsi et al.[1] The model was extended to measure the degree of the splash generation for different liquid densities at certain heights above the free surface. The simulation results showed that the two-thirds lance submergence level provided better mixing and high liquid velocities for the generation of turbulence inside the water bath. However, it is also responsible for generating more splashes in the bath compared with the one-third lance submergence level. An approach generally used by heating, ventilation, and air conditioning (HVAC) system simulations was applied to predict the convective mixing phenomena. The simulation results for the air-water system showed that mean convective mixing for swirl flow is more than twice than that of nonswirl in close proximity to the lance. A semiempirical equation was proposed from the results of the present simulation to measure the vertical penetration distance of the air jet injected through the annulus of the lance in the cylindrical vessel of the model, which can be expressed as L_{va} = 0.275( {do - di } )Frm^{0.4745} . More work still needs to be done to predict the detail process kinetics in a real furnace by considering nonisothermal high-temperature systems with chemical reactions.
1989-07-01
enzyme in a 1.5 ml Eppendorf tube. Appropriate amounts of distilled water and 1OX buffer were added to give a total volume of 100 pl. Reaction...mixtures were incubated in a 370 C water bath for 2 to 15 h. Digests were heated at 650C for 10 minutes to stop reactions and then resolved on agarose gels...430 C water bath with shaking (160 rpm) for 4 hours. The culture was transferred in a similar manner three additional times. Following the fourth
Public Notice: Bath Iron Works, CWA-01-2018-0033; EPCRA-01-2018-0034
Notice of Proposed Assessment of Class II Civil Penalty and Notice of Opportunity for a Hearing under Sections 309(g) of the Clean Water Act (CWA) for Bath Iron Works, CWA-01-2018-0033; EPCRA-01-2018-0034
Method for the production of fabricated hollow microspheroids
Wickramanayake, Shan; Luebke, David R.
2015-06-09
The method relates to the fabrication of a polymer microspheres comprised of an asymmetric layer surrounding a hollow interior. The fabricated hollow microsphere is generated from a nascent hollow microsphere comprised of an inner core of core fluid surrounded by a dope layer of polymer dope, where the thickness of the dope layer is at least 10% and less than 50% of the diameter of the inner core. The nascent hollow microsphere is exposed to a gaseous environment, generating a vitrified hollow microsphere, which is subsequently immersed in a coagulation bath. Solvent exchange produces a fabricated hollow microsphere comprised of a densified outer skin surrounding a macroporous inner layer, which surrounds a hollow interior. In an embodiment, the polymer is a polyimide or a polyamide-imide, and the non-solvent in the core fluid and the coagulation bath is water. The fabricated hollow microspheres are particularly suited as solvent supports for gas separation processes.
Robinson, J.W.
1958-08-26
A method is presented for restoring the effectiveness of bronze coating baths used for hot dip coating of uranium. Such baths, containing a high proportion of copper, lose their ability to wet uranium surfaces after a period of use. The ability of such a bath to wet uranium can be restored by adding a small amount of metallic aluminum to the bath, and skimming the resultant hard alloy from the surface.
NASA Astrophysics Data System (ADS)
Shimodozono, Megumi; Matsumoto, Shuji; Ninomiya, Koji; Miyata, Ryuji; Ogata, Atsuko; Etoh, Seiji; Watanabe, Satoshi; Kawahira, Kazumi
2012-09-01
To preliminarily assess the acute effects of a single warm -water bath (WWB) on serum adipokine activity, we measured serum adiponectin, leptin and other metabolic profiles before, immediately after and 30 minutes after WWB in seven healthy male volunteers (mean age, 39.7 ± 6.0 years; mean body mass index, 21.6 ± 1.8 kg/m2). The subjects were immersed in tap water at 41°C for 10 minutes. Two weeks later, the same subjects underwent a single WWB with a bath additive that included inorganic salts and carbon dioxide (WWB with ISCO2) by the same protocol as for the first WWB. Leptin levels significantly increased immediately after WWB with tap water and ISCO2 (both P < 0.05), and remained significantly higher than those at baseline even 30 minutes after WWB with tap water ( P < 0.05). Adiponectin levels showed a slight, but not significant, increase both immediately after and 30 minutes after WWB with tap water or ISCO2. Some parameters, such as serum total cholesterol, red blood cell count, hemoglobin and hematocrit significantly increased immediately after WWB with tap water or ISCO2 (all P < 0.05), but they all returned to the baseline levels 30 minutes after bathing under both conditions. The sublingual temperature rose significantly after 10 minutes of WWB with tap water (0.96 ± 0.16°C relative to baseline, P < 0.01) and after the same duration of WWB with ISCO2 (1.24 ± 0.34°C relative to baseline, P < 0.01). These findings suggest that a single WWB at 41°C for 10 minutes may modulate leptin and adiponectin profiles in healthy men.
Special features of the technology of boronizing steel in a calcium chloride melt
NASA Astrophysics Data System (ADS)
Chernov, Ya. B.; Anfinogenov, A. I.; Veselov, I. N.
1999-12-01
A technology for hardening machine parts and tools by boronizing in molten calcium chloride with amorphous-boron powder in electrode salt baths has been developed with the aim of creating a closed cycle of utilizing the raw materials and the washing water. A process of boronizing that includes quenching and tempering of the boronized articles is described. The quenching medium is an ecologically safe and readily available aqueous solution of calcium chloride. The process envisages return of the melt components to the boronizing bath. Boronizing by the suggested method was tested for different classes of steel, namely, structural and tool steels for cold and hot deformation. The wear resistance of the boronized steels was studied.
2002-01-01
and water solubility, as well as low toxicity and the ability to be easily detected by analytical methods. It is the approved simulant used in CRDC... coliphage (ATCC 15597-B1), a bacterial virus known for its survival capacities in the environment, was used as a biological agent to challenge the...buffer (NDS) kept in a 35°C water bath until complete dissolution of the membranes. Dilutions of MS2 assays were made in sterile PBS. Serial dilutions of
Coconut and Salmonella Infection
Schaffner, Carl P.; Mosbach, Klaus; Bibit, Venuso C.; Watson, Colin H.
1967-01-01
Raw, unprocessed coconut supports the growth of salmonellae as well as that of other enteric bacteria, salmonellae being particularly resistant to subsequent desiccation. Original contamination is not due to carriers or to polluted water supplies, but to contact with bacteria-containing soils followed by dispersion via infected coconut milk and shells. Pasteurization of raw coconut meat in a water bath at 80 C for 8 to 10 min effectively killed such bacteria, did not injure the product, and provided a prophylactic method now widely used by the coconut industry. PMID:5340650
2005-01-01
Patients with chronic prostatitis complicated by sexual dysfunction took turpentine baths with yellow solution in concentration rising from 5 to 55 ml solution per 200 l water, temperature 35-40 degrees C, duration 5-16 min, daily, 12-15 procedures. Yellow turpentine baths raise efficacy of treatment of patients with copulative dysfunction to 64% due to intensive arterial blood inflow to the sexual organs including the cavernous bodies of the penis.
[Nursing measures against adverse reaction from anti-cancer chemotherapy].
Goto, Setsuko; Mori, Machiko; Fukaya, Youko; Nakamura, Keiko
2003-06-01
Combination chemotherapy for leukemia develops bone marrow suppression. Infection or hemorrhage disorders the treatment, and may influence the clinical result. The caring staff must understand the pathology of bone marrow suppression. Visitors observe the hospital rules. Foods are also limited, city water and uncooked foods are prohibited. To keep oral cavity clean, pretreatment of some decayed teeth, and frequent gargling with sterilized water are needed. Defecation control is important. Sitz bath or shower toilet is helpful. Hand cleaning is essential for before a meal, after defecation and after a going out. Bathing is fundamental to cleaning body. No bathing is dirty. Medical catheters are checked up every day. Thrombocytopenia(< 30,000/microliter) develops a spontaneous bleeding. Severe thrombocytopenia(< 10,000/microliter) does a fatal organ bleeding.
A rapid and efficient assay for extracting DNA from fungi
Griffin, Dale W.; Kellogg, C.A.; Peak, K.K.; Shinn, E.A.
2002-01-01
Aims: A method for the rapid extraction of fungal DNA from small quantities of tissue in a batch-processing format was investigated. Methods and Results: Tissue (< 3.0 mg) was scraped from freshly-grown fungal isolates. The tissue was suspended in buffer AP1 and subjected to seven rounds of freeze/thaw using a crushed dry ice/ethanol bath and a boiling water bath. After a 30 min boiling step, the tissue was quickly ground against the wall of the microfuge tube using a sterile pipette tip. The Qiagen DNeasy Plant Tissue Kit protocol was then used to purify the DNA for PCR/ sequencing applications. Conclusions: The method allowed batch DNA extraction from multiple fungal isolates using a simple yet rapid and reliable assay. Significance and Impact of the Study: Use of this assay will allow researchers to obtain DNA from fungi quickly for use in molecular assays that previously required specialized instrumentation, was time-consuming or was not conducive to batch processing.
Fabrication of CIGS Films by Electrodeposition Method for Photovoltaic Cells
NASA Astrophysics Data System (ADS)
Lee, Hyunju; Yoon, Hyukjoo; Ji, Changwook; Lee, Dongyun; Lee, Jae-Ho; Yun, Jae-Ho; Kim, Yangdo
2012-12-01
Cu(InGa)Se2 (CIGS) thin films were fabricated by electrochemical deposition in a single bath containing Cu, In, Ga, and Se ions. The electrolyte was prepared by dissolving CuCl2, InCl3, GaCl3, H2SeO3, and LiCl in deionized water. The potentiostatic deposition process was achieved by applying a voltage ranging from -0.5 V to -0.8 V versus Ag/AgCl. The effects of different chemical bath concentrations on the film composition and morphology were investigated. Stoichiometric CIGS film composition could be achieved by controlling the chemical compositions of the bath and the voltage. Gelatin was added to the solution to improve the surface and microstructures of the CIGS film. The as-deposited films were annealed at 500°C in Ar atmosphere for crystallization. The structural, morphological, and compositional properties of the CIGS thin films before and after annealing were examined by x-ray diffraction, scanning electron microscopy, and energy-dispersive spectroscopy. This study showed that the composition of the CIGS films is dependent on the bath concentration, whereas the applied potential had relatively less effect on the CIGS film composition. In addition, the use of gelatin helped in the fabrication of crack-free CIGS thin films with greatly improved surface morphology.
Tcaciuc, A Patricia; Apell, Jennifer N; Gschwend, Philip M
2015-12-01
Understanding the transfer of chemicals between passive samplers and water is essential for their use as monitoring devices of organic contaminants in surface waters. By applying Fick's second law to diffusion through the polymer and an aqueous boundary layer, the authors derived a mathematical model for the uptake of chemicals into a passive sampler from water, in finite and infinite bath conditions. The finite bath model performed well when applied to laboratory observations of sorption into polyethylene (PE) sheets for various chemicals (polycyclic aromatic hydrocarbons, polychlorinated biphenyls [PCBs], and dichlorodiphenyltrichloroethane [DDT]) and at varying turbulence levels. The authors used the infinite bath model to infer fractional equilibration of PCB and DDT analytes in field-deployed PE, and the results were nearly identical to those obtained using the sampling rate model. However, further comparison of the model and the sampling rate model revealed that the exchange of chemicals was inconsistent with the sampling rate model for partially or fully membrane-controlled transfer, which would be expected in turbulent conditions or when targeting compounds with small polymer diffusivities and small partition coefficients (e.g., phenols, some pesticides, and others). The model can be applied to other polymers besides PE as well as other chemicals and in any transfer regime (membrane, mixed, or water boundary layer-controlled). Lastly, the authors illustrate practical applications of this model such as improving passive sampler design and understanding the kinetics of passive dosing experiments. © 2015 SETAC.
Guo, Q; Piyasena, P; Mittal, G S; Si, W; Gong, J
2006-04-01
The effectiveness of radio frequency (RF) cooking on the inactivation of Escherichia coli in ground beef and its effect on the shelf stability of ground beef were investigated with a comparison to hot water-bath cooking. E. coli K12 was used as a target bacterium instead of E. coli O157:H7. The ground beef samples inoculated with E. coli K12 (ampr) were heated until the centre temperature of each sample reached 72 degrees C. These samples were then stored at 4 degrees C for up to 30 days. The enumeration of E. coli K12, background E. coli and coliform counts in ground beef samples was carried out for shelf-life study. Although both methods significantly reduced E. coli K12 (ampr), E. coli and coliform counts and extended the shelf-life, RF cooking had a shorter cooking time, and more uniform heating. Thus, RF cooking of meat has a high potential as a substitute for the hot water-bath cooking.
Effect of bathing on atopic dermatitis during the summer season
Kim, Hakyoung; Ban, Jeongsuk; Park, Mi-Ran; Kim, Do-Soo; Kim, Hye-Young; Han, Youngshin; Ahn, Kangmo
2012-01-01
Background There are little objective data regarding the optimal practice methods of bathing, although bathing and the use of moisturizers are the most important facets to atopic dermatitis (AD) management. Objective We performed this study to evaluate the effect of bathing on AD. Methods Ninety-six children with AD were enrolled during the summer season. Parents were educated to bathe them once daily with mildly acidic cleansers, and to apply emollients for 14 days. Parents recorded the frequency of bathing and skin symptoms in a diary. Scoring AD (SCORAD) scores were measured at the initial and follow-up visits. Patients were divided into two groups, based on the compliance of bathing; poor compliance was defined as ≥ 2 bathless days. Results There was an improvement of SCORAD score, itching, and insomnia in the good compliance group (all p < 0.001). The mean change in SCORAD score from the baseline at the follow-up visit was greater in the good compliance group than the poor compliance group (p = 0.038). Conclusion Daily bathing using weakly acidic syndets can reduce skin symptoms of pediatric AD during the summer season. PMID:23130333
Immunomodulation of Hyperthermia for Recurrent Prostate Cancer
2006-03-01
cells treated with Hyperthermia (HT). HT was administered either as incubation in a 43.7oC water bath or by High frequency focused ultrasound ( HIFU ...immunity and improve local and distant tumor regression. B. BODY B.1. HT induced by water bath (43.7C,1hr) in vivo was compared to HIFU in vivo... HIFU induces coagulative tissue necrosis in the focal zone by rapidly elevating tissue temperature in a short exposure (seconds) while keeping the
75 FR 65704 - Office of Hazardous Materials Safety; Notice of Application for Special Permits
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-26
... alternative method in lieu of the required hot water bath. (Modes 1, 2, 3, 4, 5). 15136-N Luxfer Gas Cylinders....205. sale and use of a non-DOT specification fully- wrapped carbon fiber composite cylinder with a seamless aluminum liner designed, manufactured and tested in accordance with ISO 11119 part 2. (Modes 1, 2...
DOT National Transportation Integrated Search
1971-01-01
Concomitant with the Research Council's studies of accelerated curing for strength testing, Subcommittee II-i of ASTM Committee C-9 was developing and refining accelerated methods for standardization. This development included a cooperative testing p...
[Pseudomonas folliculitis after spa bath exposure].
Uldall Pallesen, Kristine Appel; Andersen, Klaus Ejner; Mørtz, Charlotte Gotthard
2012-06-25
Pseudomonas aeruginosa is a rare cause of folliculitis. Pseudomonas folliculitis can develop after contact with contaminated water from swimming pools, hot tubs and spa baths. Systemic therapy may be indicated in patients with widespread lesions, systemic symptoms or in immunosuppressed patients. We describe a 23-year-old healthy woman who developed a pustular rash and general malaise after using a spa bath contaminated with Pseudomonas aeruginosa. Bacterial culture from a pustule confirmed Pseudomonas folliculitis and the patient was treated with ciprofloxacin with rapid good effect.
Liu, Hao; Zhu, Lili; Bai, Shuming; Shi, Qiang
2014-04-07
We investigated applications of the hierarchical equation of motion (HEOM) method to perform high order perturbation calculations of reduced quantum dynamics for a harmonic bath with arbitrary spectral densities. Three different schemes are used to decompose the bath spectral density into analytical forms that are suitable to the HEOM treatment: (1) The multiple Lorentzian mode model that can be obtained by numerically fitting the model spectral density. (2) The combined Debye and oscillatory Debye modes model that can be constructed by fitting the corresponding classical bath correlation function. (3) A new method that uses undamped harmonic oscillator modes explicitly in the HEOM formalism. Methods to extract system-bath correlations were investigated for the above bath decomposition schemes. We also show that HEOM in the undamped harmonic oscillator modes can give detailed information on the partial Wigner transform of the total density operator. Theoretical analysis and numerical simulations of the spin-Boson dynamics and the absorption line shape of molecular dimers show that the HEOM formalism for high order perturbations can serve as an important tool in studying the quantum dissipative dynamics in the intermediate coupling regime.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Hao; Zhu, Lili; Bai, Shuming
2014-04-07
We investigated applications of the hierarchical equation of motion (HEOM) method to perform high order perturbation calculations of reduced quantum dynamics for a harmonic bath with arbitrary spectral densities. Three different schemes are used to decompose the bath spectral density into analytical forms that are suitable to the HEOM treatment: (1) The multiple Lorentzian mode model that can be obtained by numerically fitting the model spectral density. (2) The combined Debye and oscillatory Debye modes model that can be constructed by fitting the corresponding classical bath correlation function. (3) A new method that uses undamped harmonic oscillator modes explicitly inmore » the HEOM formalism. Methods to extract system-bath correlations were investigated for the above bath decomposition schemes. We also show that HEOM in the undamped harmonic oscillator modes can give detailed information on the partial Wigner transform of the total density operator. Theoretical analysis and numerical simulations of the spin-Boson dynamics and the absorption line shape of molecular dimers show that the HEOM formalism for high order perturbations can serve as an important tool in studying the quantum dissipative dynamics in the intermediate coupling regime.« less
NASA Astrophysics Data System (ADS)
Sudibyo, Hermida, L.; Suwardi
2017-11-01
Tapioca waste water is very difficult to treat; hence many tapioca factories could not treat it well. One of method which able to overcome this problem is electrodeposition. This process has high performance when it conducted using batch recycle process and use aluminum bipolar electrode. However, the optimum operation conditions are having a significant effect in the tapioca wastewater treatment using bath recycle process. In this research, The Taguchi method was successfully applied to know the optimum condition and the interaction between parameters in electrocoagulation process. The results show that current density, conductivity, electrode distance, and pH have a significant effect on the turbidity removal of cassava starch waste water.
Leonard, Anne F C; Zhang, Lihong; Balfour, Andrew J; Garside, Ruth; Hawkey, Peter M; Murray, Aimee K; Ukoumunne, Obioha C; Gaze, William H
2018-05-01
Antibiotic-resistant bacteria (ARB) present a global public health problem. With numbers of community-acquired resistant infections increasing, understanding the mechanisms by which people are exposed to and colonised by ARB can help inform effective strategies to prevent their spread. The role natural environments play in this is poorly understood. This is the first study to combine surveillance of ARB in bathing waters, human exposure estimates and association between exposure and colonisation by ARB in water users. 97 bathing water samples from England and Wales were analysed for the proportion of E. coli harbouring bla CTX-M . These data were used to estimate the likelihood of water users ingesting bla CTX-M -bearing E. coli. Having identified surfers as being at risk of exposure to ARB, a cross-sectional study was conducted. Regular surfers and non-surfers were recruited to assess whether there is an association between surfing and gut colonisation by bla CTX-M- bearing E. coli. 11 of 97 bathing waters sampled were found to contain bla CTX-M -bearing E. coli. While the percentage of bla CTX-M -bearing E. coli in bathing waters was low (0.07%), water users are at risk of ingesting these ARB. It is estimated that over 2.5 million water sports sessions occurred in 2015 resulting in the ingestion of at least one bla CTX-M -bearing E. coli. In the epidemiological survey, 9/143 (6.3%) surfers were colonised by bla CTX-M -bearing E. coli, as compared to 2/130 (1.5%) of non-surfers (risk ratio=4.09, 95% CI 1.02 to 16.4, p=0.046). Surfers are at risk of exposure to and colonisation by clinically important antibiotic-resistant E. coli in coastal waters. Further research must be done on the role natural environments play in the transmission of ARB. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.
Iwase, Satoshi; Kawahara, Yuko; Nishimura, Naoki; Nishimura, Rumiko; Miwa, Chihiro; Kataoka, Yumiko; Kobayashi, Chihiro; Suzuki, Takahiro; Shigaraki, Masayuki; Maeda, Yoichi; Takada, Hiroki; Watanabe, Yoriko
2014-07-01
To reduce the risks of Japanese-style bathing, half-body bathing (HBLB) has been recommended in Japan, but discomfort due to the cold environment in winter prevents its widespread adoption. The development of the mist sauna, which causes a gradual core temperature rise with sufficient thermal comfort, has reduced the demerits of HBLB. We examined head-out 42 °C mist bathing with 38 °C HBLB up to the navel to see if it could improve thermal comfort without detracting from the merits of HBLB, with and without the effects of facial fanning (FF). The subjects were seven healthy males aged 22-25 years. The following bathing styles were provided: (1) HBLB-head-out half-body low bathing of 38 °C up to the navel (20 min); (2) HOMB-head-out mist bathing of 42 °C and HBLB of 38 °C (20 min); and (3) HOMBFF-HOMB with FF (20 min). HOMB raised the core temperature gradually. HOMBFF suppressed the core temperature rise in a similar fashion to HOMB. Increases in blood pressure and heart rate usually observed in Japanese traditional-style bathing were less marked in HOMBs with no significant difference with and without FF. The greatest body weight loss was observed after Japanese traditional-style bathing, with only one-third of this amount lost after mist bathing, and one-sixth after HBLB. HOMB increased thermal sensation, and FF also enhanced post-bathing invigoration. We conclude that HOMB reduces the risks of Japanese traditional style bathing by mitigating marked changes in the core temperature and hemodynamics, and FF provides thermal comfort and invigoration.
NASA Astrophysics Data System (ADS)
Iwase, Satoshi; Kawahara, Yuko; Nishimura, Naoki; Nishimura, Rumiko; Miwa, Chihiro; Kataoka, Yumiko; Kobayashi, Chihiro; Suzuki, Takahiro; Shigaraki, Masayuki; Maeda, Yoichi; Takada, Hiroki; Watanabe, Yoriko
2014-07-01
To reduce the risks of Japanese-style bathing, half-body bathing (HBLB) has been recommended in Japan, but discomfort due to the cold environment in winter prevents its widespread adoption. The development of the mist sauna, which causes a gradual core temperature rise with sufficient thermal comfort, has reduced the demerits of HBLB. We examined head-out 42 °C mist bathing with 38 °C HBLB up to the navel to see if it could improve thermal comfort without detracting from the merits of HBLB, with and without the effects of facial fanning (FF). The subjects were seven healthy males aged 22-25 years. The following bathing styles were provided: (1) HBLB—head-out half-body low bathing of 38 °C up to the navel (20 min); (2) HOMB—head-out mist bathing of 42 °C and HBLB of 38 °C (20 min); and (3) HOMBFF—HOMB with FF (20 min). HOMB raised the core temperature gradually. HOMBFF suppressed the core temperature rise in a similar fashion to HOMB. Increases in blood pressure and heart rate usually observed in Japanese traditional-style bathing were less marked in HOMBs with no significant difference with and without FF. The greatest body weight loss was observed after Japanese traditional-style bathing, with only one-third of this amount lost after mist bathing, and one-sixth after HBLB. HOMB increased thermal sensation, and FF also enhanced post-bathing invigoration. We conclude that HOMB reduces the risks of Japanese traditional style bathing by mitigating marked changes in the core temperature and hemodynamics, and FF provides thermal comfort and invigoration.
NASA Astrophysics Data System (ADS)
Wu, Xuelian; Zhang, Wuyi; Liu, Yanju; Leng, Jinsong
2007-07-01
Thermally activated shape memory polymers (SMPs) receive increasing attention in recent years. Different from those reported in the literature, in this paper we propose a new approach, i.e., using infrared light, for heating SMPs for shape recovery. We compare this approach with the traditional water bath method in terms of shape recovery speed in bending at both vacuum and no vacuum conditions. The results reveal that the shape recovery speed in infrared heating at vacuum condition is about eight times slower than that by hot water. However, the recovery time is more than doubled if without vacuum.
Nizamani, Sooraj; Kazi, Tasneem G; Afridi, Hassan I
2018-01-01
An efficient preconcentration technique based on ultrasonic-assisted ionic liquid-based dual microextraction (UA-ILDµE) method has been developed to preconcentrate the lead (Pb +2 ) in ground and stored rain water. In the current proposed method, Pb +2 was complexed with a chelating agent (dithizone), whereas an ionic liquid (1-butyl-3-methylimidazolium hexafluorophosphate) was used for extraction purpose. The ultrasonic irradiation and electrical shaking system were applied to enhance the dispersion and extraction of Pb +2 complex in aqueous samples. For second phase, dual microextraction (DµE phase), the enriched Pb +2 complex in ionic liquid, extracted back into the acidic aqueous solution and finally determined by flame atomic absorption spectrometry. Some major analytical parameters that influenced the extraction efficiency of developed method, such as pH, concentration of ligand, volume of ionic liquid and samples, time of shaking in thermostatic electrical shaker and ultrasonic bath, effect of back extracting HNO 3 volume, matrix effect, centrifugation time and rate were optimized. At the sample volume of 25mL, the calculated preconcentration factor was 62.2. The limit of detection of proposed procedure for Pb +2 ions was found to be 0.54μgL -1 . The validation of developed method was performed by the analysis of certified sample of water SRM 1643e and standard addition method in a real water sample. The extraction recovery of Pb +2 was enhanced≥2% with shaking time of 80s in ultrasonic bath as compared to used thermostatic electrical shaker, where for optimum recovery up to 10min was required. The developed procedure was successfully used for the enrichment of Pb +2 in ground and stored rain water (surface water) samples of an endemic region of Pakistan. The resulted data indicated that the ground water samples were highly contaminated with Pb +2 , while some of the surface water samples were also have higher values of Pb +2 than permissible limit of WHO. The concentration of Pb +2 in surface and ground water samples was found in the range of 17.5-24.5 and 25.6-99.1μgL - 1 respectively. Copyright © 2017 Elsevier B.V. All rights reserved.
Grantham, LeRoy F.
1979-01-01
An organic waste containing at least one element selected from the group consisting of strontium, cesium, iodine and ruthenium is treated to achieve a substantial reduction in the volume of the waste and provide for fixation of the selected element in an inert salt. The method of treatment comprises introducing the organic waste and a source of oxygen into a molten salt bath maintained at an elevated temperature to produce solid and gaseous reaction products. The gaseous reaction products comprise carbon dioxide and water vapor, and the solid reaction products comprise the inorganic ash constituents of the organic waste and the selected element which is retained in the molten salt. The molten salt bath comprises one or more alkali metal carbonates, and may optionally include from 1 to about 25 wt.% of an alkali metal sulfate.
Colonization of Legionella species in Turkish baths in hotels in Alanya, Turkey.
Erdogan, Haluk; Arslan, Hande
2015-05-01
This study evaluated the prevalence of Legionella species in water samples collected from Turkish baths in hotels in Alanya, Turkey, from August 2003 to September 2013. Water samples were collected in 100-mL sterile containers and then concentrated by filtration. Heat treatment was used to eliminate other microorganisms from the samples, which were then spread on Legionella-selective-buffered charcoal yeast extract alpha (BCYE-α) agar and on BCYE-α agar supplemented with glycine, vancomycin, polymyxin, and cycloheximide. Cysteine-dependent colonies were identified by latex agglutination. In total, 135 samples from 52 hotels with Turkish baths were evaluated. Legionella species were identified in 11/52 (21.2%) hotels and 18/135 (13.3%) samples. The most frequently isolated species was Legionella pneumophila, with most isolates belonging to serogroups 6 (55.6%) and 1 (22.2%). The colony count was <100 colony-forming units (CFU) mL(-1) in nine samples, from 100 to 1000 CFU mL(-1) in six samples, and >1000 CFU mL(-1) in three samples. These findings suggest that the hot water systems of Turkish baths in hotels must be viewed as a possible source of travel-associated Legionnaires' disease, and preventative measures should be put in place.
Jasper, Ahren W; Miller, James A; Klippenstein, Stephen J
2013-11-27
The low-pressure-limit unimolecular decomposition of methane, CH4 (+M) ⇆ CH3 + H (+M), is characterized via low-order moments of the total energy, E, and angular momentum, J, transferred due to collisions. The low-order moments are calculated using ensembles of classical trajectories, with new direct dynamics results for M = H2O and new results for M = O2 compared with previous results for several typical atomic (M = He, Ne, Ar, Kr) and diatomic (M = H2 and N2) bath gases and one polyatomic bath gas, M = CH4. The calculated moments are used to parametrize three different models of the energy transfer function, from which low-pressure-limit rate coefficients for dissociation, k0, are calculated. Both one-dimensional and two-dimensional collisional energy transfer models are considered. The collision efficiency for M = H2O relative to the other bath gases (defined as the ratio of low-pressure limit rate coefficients) is found to depend on temperature, with, e.g., k0(H2O)/k0(Ar) = 7 at 2000 K but only 3 at 300 K. We also consider the rotational collision efficiency of the various baths. Water is the only bath gas found to fully equilibrate rotations, and only at temperatures below 1000 K. At elevated temperatures, the kinetic effect of "weak-collider-in-J" collisions is found to be small. At room temperature, however, the use of an explicitly two-dimensional master equation model that includes weak-collider-in-J effects predicts smaller rate coefficients by 50% relative to the use of a statistical model for rotations. The accuracies of several methods for predicting relative collision efficiencies that do not require solving the master equation and that are based on the calculated low-order moments are tested. Troe's weak collider efficiency, βc, includes the effect of saturation of collision outcomes above threshold and accurately predicts the relative collision efficiencies of the nine baths. Finally, a brief discussion is presented of mechanistic details of the energy transfer process, as inferred from the trajectories.
Kawaguchi, Tomohiro; Arakawa, Kazuya; Nomura, Kazuhiro; Ogawa, Yoshikazu; Katori, Yukio; Tominaga, Teiji
2017-12-01
Endoscopic endonasal surgery, an innovative surgical technique, is used to approach sinus lesions, lesions of the skull base, and intradural tumors. The cooperation of experienced otolaryngologists and neurosurgeons is important to achieve safe and reliable surgical results. The bath plug closure method is a treatment option for patients with cerebrospinal fluid(CSF)leakage. Although it includes dural and/or intradural procedures, surgery tends to be performed by otolaryngologists because its indications, detailed maneuvers, and pitfalls are not well recognized by neurosurgeons. We reviewed the cases of patients with CSF leakage treated by using the bath plug closure method with an endoscopic endonasal approach at our institution. Three patients were treated using the bath plug closure method. CSF leakage was caused by a meningocele in two cases and trauma in one case. No postoperative intracranial complications or recurrence of CSF leakage were observed. The bath plug closure method is an effective treatment strategy and allows neurosurgeons to gain in-depth knowledge of the treatment options for CSF leakage by using an endoscopic endonasal approach.
[Interlaboratory Study on Evaporation Residue Test for Food Contact Products (Report 1)].
Ohno, Hiroyuki; Mutsuga, Motoh; Abe, Tomoyuki; Abe, Yutaka; Amano, Homare; Ishihara, Kinuyo; Ohsaka, Ikue; Ohno, Haruka; Ohno, Yuichiro; Ozaki, Asako; Kakihara, Yoshiteru; Kobayashi, Hisashi; Sakuragi, Hiroshi; Shibata, Hiroshi; Shirono, Katsuhiro; Sekido, Haruko; Takasaka, Noriko; Takenaka, Yu; Tajima, Yoshiyasu; Tanaka, Aoi; Tanaka, Hideyuki; Tonooka, Hiroyuki; Nakanishi, Toru; Nomura, Chie; Haneishi, Nahoko; Hayakawa, Masato; Miura, Toshihiko; Yamaguchi, Miku; Watanabe, Kazunari; Sato, Kyoko
2018-01-01
An interlaboratory study was performed to evaluate the equivalence between an official method and a modified method of evaporation residue test using three food-simulating solvents (water, 4% acetic acid and 20% ethanol), based on the Japanese Food Sanitation Law for food contact products. Twenty-three laboratories participated, and tested the evaporation residues of nine test solutions as blind duplicates. For evaporation, a water bath was used in the official method, and a hot plate in the modified method. In most laboratories, the test solutions were heated until just prior to evaporation to dryness, and then allowed to dry under residual heat. Statistical analysis revealed that there was no significant difference between the two methods, regardless of the heating equipment used. Accordingly, the modified method provides performance equal to the official method, and is available as an alternative method.
Acute response to hydrotherapy after a simulated game of rugby.
Higgins, Trevor R; Cameron, Melainie L; Climstein, Mike
2013-10-01
Despite lacking clear scientific evidence, hydrotherapies (water treatments) are accepted techniques to help team sport athletes recover from the physical effects of games. The purpose of this study was to assess the comparative effectiveness of cold water immersions (CWIs) and hot-and-cold contrast baths on athletes' recovery after a simulated game of rugby union. Twenty-four experienced, well-trained, male rugby union players were divided into 3 groups to receive recovery interventions: CWI for 1 group, contrast baths for a second group, and passive recovery for a third (control) group. Pregame and postgame measurements included a countermovement jump (normalized as a ratio to body weight), a sit-and-stretch flexibility test (centimeters), thigh circumference (to detect swelling; centimeters), and participants' perception of delayed-onset muscular soreness (DOMS, 100-mm visual analog scale). Statistical analysis included analysis of variance, and the calculation of omnibus effect sizes for each group ((Equation is included in full-text article.)) and the magnitudes of change within and between groups (Cohen's d). The participants in the contrast bath group reported statistically significantly greater measures of DOMS than participants in the control group did at 1 hour postintervention (p = 0.05, control group: d = 1.80; contrast bath: d = 4.75), and than participants in the CWI group did at 48 hours postintervention (p = 0.02, CWI: d = 1.17; contrast bath: d = 1.97). These findings provide modest evidence that contrast baths are a less effective strategy for recovery from rugby union than are CWI or passive recovery. Specifically, 2 × 5-minute CWI is superior to both contrasts baths and passive recovery in alleviating DOMS after exercise-induced muscle damage. Our recommendation for rugby union players aiming to attenuate the effects of DOMS postgames is to take 2 × 5-minute CWIs baths immediately after the game.
2014-01-01
Background Human health risk assessment from exposure to disinfection by-products (DBPs) during drinking and bathing water vary from country to country as per life expectancy, body mass index, water consumption pattern and individual concentration of DBPs component, etc. Methods Present study considered average direct water intake per person for adult males and females as 4 & 3 L/day, respectively as per Indian literature for risk evaluation from another component of pollutant. While other important factor like average life expectancy, body weight & body surface area for male and female were considered 64 & 67 years, 51.9 & 45.4 Kg and 1.54 & 1.38 m2 respectively as per Indian Council of Medical Research and WHO report. The corresponding lifetime cancer risk of the formed THMs to human beings was estimated by the USEPA and IRIS method as per Indian population. Results The total cancer risk reached 8.99 E-04 and 8.92 E-04 for males and females, respectively, the highest risk from THMs seems to be from the inhalation route followed by ingestion and dermal contacts. Conclusions The multipath way evaluations of lifetime cancer risks for THMs exposure through ingestion, dermal absorption, and inhalation exposure were examined at the highest degree of danger. Results reveals that water containing THMs of the selected water treatment plant of the eastern part of India was unsafe in terms of risk evaluation through inhalation and ingestion, while dermal route of risk was found very close to permissible limit of USEPA. Sensitivity analysis shows that every input parameter is sole responsible for total risk potential, whereas exposure duration playing important role for estimation of total risk. PMID:24872885
Quilliam, Richard S; Jamieson, Julie; Oliver, David M
2014-07-15
The revised Bathing Water Directive (rBWD) introduces more stringent standards for microbial water quality and promotes more pro-active management of the beach environment through the production of a bathing water profile (BWP). The aim of this study was to determine whether living seaweeds in the littoral zone are colonised by faecal indicator organisms (FIOs), and to quantify the survival dynamics of waterborne Escherichia coli in microcosms containing senescing seaweeds. Living seaweed (Fucus spiralis) was not associated with FIO colonisation, although could be providing a protected environment in the underlying sand. Senescing seaweeds enhanced waterborne E. coli survival compared to plastic debris, with the brown seaweed Laminaria saccharina facilitating greater E. coli persistence than either Chondrus crispus or Ulva lactuca. This has important implications for FIO survival on bathing beaches as the majority of beach-cast biomass is composed of brown seaweeds, which could support significant levels of FIOs. Copyright © 2014 Elsevier Ltd. All rights reserved.
40 CFR Appendix A-6 to Part 60 - Test Methods 16 through 18
Code of Federal Regulations, 2010 CFR
2010-07-01
... maintaining the probe, filter box, and connections at a temperature of at least 120 °C (248 °F). Moisture is... temperature is above 0 °C (32 °F). Alternatively, moisture may be eliminated by heating the sample line, and... (2 in.). Immerse the impingers in an ice water bath and maintain near 0 °C (32 °F). The scrubber...
40 CFR Appendix A-6 to Part 60 - Test Methods 16 through 18
Code of Federal Regulations, 2011 CFR
2011-07-01
... maintaining the probe, filter box, and connections at a temperature of at least 120 °C (248 °F). Moisture is... temperature is above 0 °C (32 °F). Alternatively, moisture may be eliminated by heating the sample line, and... (2 in.). Immerse the impingers in an ice water bath and maintain near 0 °C (32 °F). The scrubber...
Barnatskiĭ, V V
2009-01-01
A differential approach to the use of selected methods of radon therapy (including dry air and water baths with different radon concentrations) is proposed for the treatment of different nosological forms of seronegative spondyloarthritis taking into consideration their varying clinical manifestations (arthritis, enthesitis, spondylitis), the degree of general clinical activity, functional state, and severity of inflammation (based on laboratory analyses).
Special Advanced Studies for Pollution Prevention. Delivery Order 0058: The Monitor - Winter 2000
2001-04-01
Burning/Open Detonation of Energetic Materials ➨Emission factors from a draft EPA report are incorporated into the guidance Site Restoration ➨Method...Aqueous Cleaner Recycle System Microfiltration Removes oil/grease & TSS from alkaline and acid cleaning baths Commodore Separation Technologies, Inc... Microfiltration Removes all heavy metals from wastewater and recycles water Infinity Chemicals Group Infinity Prep-L Deoxidizing Chemical
Water-cooled probe technique for the study of freeze lining formation
NASA Astrophysics Data System (ADS)
Verscheure, Karel; Campforts, Mieke; Verhaeghe, Frederik; Boydens, Eddy; Blanpain, Bart; Wollants, Patrick; van Camp, Maurits
2006-12-01
Furnace protection by water-cooled freeze linings becomes increasingly important as the metal producing industry attempts to achieve higher process intensities. Systematic investigations of the growth and the resulting microstructure and compositional profile of freeze linings are necessary to understand the behavior of freeze linings, their relation with the industrial process, and their interaction with the wall cooling system. We have developed a technique based on the submergence of a water-cooled probe into a liquid slag bath. Freeze linings of two industrial nonferrous slags have been produced using this technique and their growth, microstructural, and compositional profiles as a function of submergence time were determined. Thermodynamic equilibrium for the investigated slag systems was calculated and compared with the observed microstructures. The freeze linings form in approximately 15 minutes. Close to the water cooling, the freeze linings are predominantly amorphous in structure. With increasing distance from the water cooling, the proportion of crystalline phases increases and bath material is entrapped in the microstructure. Cellular crystals are observed close to the bath. The freeze linings exhibit an approximate homogeneous composition. The results demonstrate that the technique is a successful tool in obtaining information on the growth, microstructure, and composition of freeze linings in industrial water-cooled furnaces.
Comparison of the susceptibility of four rainbow trout strains to cold-water disease.
Wagner, Eric J; Oplinger, Randall W
2014-09-01
Abstract Susceptibility to cold-water disease was compared among four strains of Rainbow Trout Oncorhynchus mykiss: Arlee strain from Ennis National Fish Hatchery, Montana (AL-EN), the Arlee strain from Jocko River Hatchery, Montana (AL-JR), a cold-water disease-resistant strain (WV), and the Harrison-Hofer strain (HH). Bacterial challenges were either by bath or intraperitoneal injection (50 μL of 0.65 optical density). Each strain was exposed at 75 d after hatch to either the CSF 259-93 (Idaho) or 09-104 isolate (Utah) of Flavobacterium psychrophilum. Injection controls received a phosphate-buffered saline (PBS) solution and bath controls were exposed to uninoculated sterile broth (tryptone yeast extract salts) mixed 1:1 with hatchery well water. For injected fish, the WV had significantly lower mortality (20.0-36.7%) than HH and AL-EN (76.7-96.7%) but did not significantly differ from AL-JR (46.7-56.7%). Injected fish had significantly higher mortality than bath-exposed fish. For bath-exposed fish, the WV had significantly lower mortality (0%) than the HH (10.0-26.7%), but both Arlee strains had intermediate mortality values (0-13.3%) that did not significantly differ from either the HH or WV strain. There were no significant differences between the two bacterial isolates, indicating similar virulence and similar resistance response of WV to another novel isolate of F. psychrophilum. Received November 5, 2013; accepted April 15, 2014.
Fujimoto, Sawako; Iwawaki, Yoko; Takishita, Yukie; Yamamoto, Yoko; Murota, Masako; Yoshioka, Saori; Hayano, Azusa; Hosokawa, Toyoshi; Yamanaka, Ryuya
2017-11-01
In palliative care hospitals in Japan, mechanical bathing is conducted to maintain cleanliness. However, the physiological and psychological influence of mechanical bathing on patients has not been sufficiently studied. The objective of this study was to assess, using physiological and psychological indices, the effects of mechanical bathing care for patients in the terminal stage of cancer. Mechanical bathing was performed using a Marine Court SB7000 in a supine or semi-seated position. The heart rate variability analysis method was used to measure autonomic nervous system function. The patients' state of anxiety was assessed using the State-Trait Anxiety Inventory (STAI), a psychological index, and patients' verbal responses were also collected after mechanical bathing. Twenty-four patients were enrolled in this study. Their sympathetic and parasympathetic nervous activity did not differ before and after bathing. A significant difference was found between pre- and post-bathing anxiety, as evaluated by STAI (P < 0.0001). In the patient's verbal responses that was collected, the most frequently mentioned descriptors were 'comfortable' and 'relaxed'. Patients were more relaxed after mechanical bathing according to STAI evaluation and their verbal responses. The findings suggest that the method of bathing used in this study is safe and pain-relieving for terminal stage cancer patients. It is thus possible to provide safe and comfortable care for terminal stage cancer patients using mechanical baths. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com
NASA Astrophysics Data System (ADS)
Ke, Yaling; Zhao, Yi
2018-04-01
The hierarchy of stochastic Schrödinger equation, previously developed under the unpolarised initial bath states, is extended in this paper for open quantum dynamics under polarised initial bath conditions. The method is proved to be a powerful tool in investigating quantum dynamics exposed to an ultraslow Ohmic bath, as in this case the hierarchical truncation level and the random sampling number can be kept at a relatively small extent. By systematically increasing the system-bath coupling strength, the symmetric Ohmic spin-boson dynamics is investigated at finite temperature, with a very small cut-off frequency. It is confirmed that the slow bath makes the system dynamics extremely sensitive to the initial bath conditions. The localisation tendency is stronger in the polarised initial bath conditions. Besides, the oscillatory coherent dynamics persists even when the system-bath coupling is very strong, in correspondence with what is found recently in the deep sub-Ohmic bath, where also the low-frequency modes dominate.
NASA Astrophysics Data System (ADS)
Sofiah, A. G. N.; Kananathan, J.; Samykano, M.; Ulakanathan, S.; Lah, N. A. C.; Harun, W. S. W.; Sudhakar, K.; Kadirgama, K.; Ngui, W. K.; Siregar, J. P.
2017-10-01
This paper investigates the influence of the electrolytic bath temperature on the morphology and physical properties of nickel (Ni) nanowires electrochemically deposited into the anodic alumina oxide porous membrane (AAO). The synthesis was performed using nickel sulfate hexahydrate (NiSO4.6H2O) and boric acid (H3BO3) as an electrolytic bath for the electrochemical deposition of Ni nanowires. During the experiment, the electrolyte bath temperature varied from 40°C, 80°C, and 120°C. After the electrochemical deposition process, AAO templates cleaned with distilled water preceding to dissolution in sodium hydroxide (NaOH) solution to obtain free-standing Ni nanowires. Field Emission Scanning Electron Microscopy (FESEM), Energy Dispersive Spectroscopy (EDX) and X-ray Diffraction (XRD) analysis were employed to characterize the morphology and physical properties of the synthesized Ni nanowires. Finding reveals the electrodeposition bath temperature significantly influences the morphology and physical properties of the synthesized Ni nanowires. Rougher surface texture, larger crystal size, and longer Ni nanowires obtained as the deposition bath temperature increased. From the physical properties properties analysis, it can be concluded that deposition bath temperature influence the physical properties of Ni nanowires.
Balcik-Canbolat, Cigdem; Sengezer, Cisel; Sakar, Hacer; Karagunduz, Ahmet; Keskinler, Bulent
2017-11-01
It has been recognized by the whole world that textile industry which produce large amounts of wastewater with strong color and toxic organic compounds is a major problematical industry requiring effective treatment solutions. In this study, reverse osmosis (RO) membranes were tested on biologically treated real dye bath wastewater with and without pretreatment by nanofiltration (NF) membrane to recovery. Also membrane fouling and reuse potential of membranes were investigated by multiple filtrations. Obtained results showed that only NF is not suitable to produce enough quality to reuse the wastewater in a textile industry as process water while RO provide successfully enough permeate quality. The results recommend that integrated NF/RO membrane process is able to reduce membrane fouling and allow long-term operation for real dye bath wastewater.
Study of different solutes for determination of neutron source strength based on the water bath
NASA Astrophysics Data System (ADS)
Khabaz, Rahim
2018-09-01
Time required for activation to saturation and background measurement is considered a limitation of strength determination of radionuclide neutron sources using manganese bath system (MBS). The objective of this research was to evaluate the other solutes based on water bath for presentation of the suitable replacement with MBS. With the aid Monte Carlo simulation, for three neutron sources, having different neutron spectra, immersed in six aqueous solutions, i.e., Na2SO4, VOSO4, MnSO4, Rh2(SO4)3, In2(SO4)3, I2O5, the correction factors in all nuclei of solutions for neutron losses with different process were obtained. The calculations results indicate that the Rh2(SO4)3 and VOSO4 are best options for replacing with MnSO4.
Processing of combined domestic bath and laundry waste waters for reuse as commode flushing water
NASA Technical Reports Server (NTRS)
Hypes, W. D.; Batten, C. E.; Wilkins, J. R.
1975-01-01
An experimental investigation of processes and system configurations for reclaiming combined bath and laundry waste waters for reuse as commode flush water was conducted. A 90-min recycle flow was effective in removing particulates and in improving other physical characteristics to the extent that the filtered water was subjectively acceptable for reuse. The addition of a charcoal filter resulted in noticeable improvements in color, turbidity, and suds elimination. Heating and chlorination of the waste waters were investigated for reducing total organism counts and eliminating coliform organisms. A temperature of 335.9 K (145 F) for 30 min and chlorine concentrations of 20 mg/l in the collection tank followed by 10 mg/l in the storage tank were determined to be adequate for this purpose. Water volume relationships and energy-use rates for the waste water reuse systems are also discussed.
Diamond, Jared M.
1966-01-01
1. The relation between osmotic gradient and rate of osmotic water flow has been measured in rabbit gall-bladder by a gravimetric procedure and by a rapid method based on streaming potentials. Streaming potentials were directly proportional to gravimetrically measured water fluxes. 2. As in many other tissues, water flow was found to vary with gradient in a markedly non-linear fashion. There was no consistent relation between the water permeability and either the direction or the rate of water flow. 3. Water flow in response to a given gradient decreased at higher osmolarities. The resistance to water flow increased linearly with osmolarity over the range 186-825 m-osM. 4. The resistance to water flow was the same when the gall-bladder separated any two bathing solutions with the same average osmolarity, regardless of the magnitude of the gradient. In other words, the rate of water flow is given by the expression (Om — Os)/[Ro′ + ½k′ (Om + Os)], where Ro′ and k′ are constants and Om and Os are the bathing solution osmolarities. 5. Of the theories advanced to explain non-linear osmosis in other tissues, flow-induced membrane deformations, unstirred layers, asymmetrical series-membrane effects, and non-osmotic effects of solutes could not explain the results. However, experimental measurements of water permeability as a function of osmolarity permitted quantitative reconstruction of the observed water flow—osmotic gradient curves. Hence non-linear osmosis in rabbit gall-bladder is due to a decrease in water permeability with increasing osmolarity. 6. The results suggest that aqueous channels in the cell membrane behave as osmometers, shrinking in concentrated solutions of impermeant molecules and thereby increasing membrane resistance to water flow. A mathematical formulation of such a membrane structure is offered. PMID:5945254
Environmental Consequences of Nanotechnologies: Nanoparticle Dispersion in Aqueous Media: SOP-T-1
2015-02-01
containing ice • Bath sonicator • Weighing dish (aluminum) • Stainless steel spatula • Analytical balance • Lab jack for lifting sample • Volumetric...balance and an aluminum dish, weigh an adequate mass of dry powder under a fume hood to achieve the desired concentration into ultrapure water (<T>, <R...0.025 0.5 0.05 1 0.5 10 1 20 2. Add ultra-pure water in a glass beaker with NP powder to /flask under fume hood (<T>, <R>). 3. Degas the bath
Chiang, Charles; Eichenfield, Lawrence F
2009-01-01
Standard recommendations for skin care for patients with atopic dermatitis stress the importance of skin hydration and the application of moisturizers. However, objective data to guide recommendations regarding the optimal practice methods of bathing and emollient application are scarce. This study quantified cutaneous hydration status after various combination bathing and moisturizing regimens. Four bathing/moisturizer regimens were evaluated in 10 subjects, five pediatric subjects with atopic dermatitis and five subjects with healthy skin. The regimens consisted of bathing alone without emollient application, bathing and immediate emollient application, bathing and delayed application, and emollient application alone. Each regimen was evaluated in all subjects, utilizing a crossover design. Skin hydration was assessed with standard capacitance measurements. In atopic dermatitis subjects, emollient alone yielded a significantly (p < 0.05) greater mean hydration over 90 minutes (206.2% baseline hydration) than bathing with immediate emollient (141.6%), bathing and delayed emollient (141%), and bathing alone (91.4%). The combination bathing and emollient application regimens demonstrated hydration values at 90 minutes not significantly greater than baseline. Atopic dermatitis subjects had a decreased mean hydration benefit compared with normal skin subjects. Bathing without moisturizer may compromise skin hydration. Bathing followed by moisturizer application provides modest hydration benefits, though less than that of simply applying moisturizer alone.
Bath-Ambience-A Mechatronic System for Assisting the Caregivers of Bedridden People.
Bezerra, Karolina; Machado, José; Carvalho, Vítor; Castro, Marcelo; Costa, Pedro; Matos, Demétrio; Soares, Filomena
2017-05-18
The health of older people is receiving special attention and dedication nowadays, with the aim of increasing their general wellbeing and quality of life. Studies into different aspects of the care of the elderly have found that emphasis should be given to solving problems related to bathing in different situations and environments. In particular, it is important to develop new assistive technologies to streamline and ease the burden of a caregiver's daily tasks. Generally-speaking, in the case of bedridden patients, bathing is typically carried out manually by a caregiver, using towels, sponges, and a water basin. Nevertheless, this apparently simple task needs some precautions in order to avoid the risk of microbial infections, falls and other injuries. With that in mind, this paper presents the design of a portable washing system, called Bath-Ambience, which enables bedridden patients to be bathed efficiently without having to be moved from their position. This portable system can be installed in different situations, both in a domestic setting, and in specialized institutions, and allows the caregiver to perform the bathing tasks without compromising health and safety, thereby making it possible to offer a comfortable and hygienic procedure to patients, improving their quality of life. This paper presents the design of the portable Bath-Ambience washing system, which provides efficient assistance for bathing bedridden patients without moving them to another place. This system is mainly dedicated for integration a smart home application in to allow bathing everywhere.
Bath-Ambience—A Mechatronic System for Assisting the Caregivers of Bedridden People
Bezerra, Karolina; Machado, José; Carvalho, Vítor; Castro, Marcelo; Costa, Pedro; Matos, Demétrio; Soares, Filomena
2017-01-01
The health of older people is receiving special attention and dedication nowadays, with the aim of increasing their general wellbeing and quality of life. Studies into different aspects of the care of the elderly have found that emphasis should be given to solving problems related to bathing in different situations and environments. In particular, it is important to develop new assistive technologies to streamline and ease the burden of a caregiver’s daily tasks. Generally-speaking, in the case of bedridden patients, bathing is typically carried out manually by a caregiver, using towels, sponges, and a water basin. Nevertheless, this apparently simple task needs some precautions in order to avoid the risk of microbial infections, falls and other injuries. With that in mind, this paper presents the design of a portable washing system, called Bath-Ambience, which enables bedridden patients to be bathed efficiently without having to be moved from their position. This portable system can be installed in different situations, both in a domestic setting, and in specialized institutions, and allows the caregiver to perform the bathing tasks without compromising health and safety, thereby making it possible to offer a comfortable and hygienic procedure to patients, improving their quality of life. This paper presents the design of the portable Bath-Ambience washing system, which provides efficient assistance for bathing bedridden patients without moving them to another place. This system is mainly dedicated for integration a smart home application in to allow bathing everywhere. PMID:28524114
Emergent transport in a many-body open system driven by interacting quantum baths
NASA Astrophysics Data System (ADS)
Reisons, Juris; Mascarenhas, Eduardo; Savona, Vincenzo
2017-10-01
We analyze an open many-body system that is strongly coupled at its boundaries to interacting quantum baths. We show that the two-body interactions inside the baths induce emergent phenomena in the spin transport. The system and baths are modeled as independent spin chains resulting in a global nonhomogeneous X X Z model. The evolution of the system-bath state is simulated using matrix-product-states methods. We present two phase transitions induced by bath interactions. For weak bath interactions we observe ballistic and insulating phases. However, for strong bath interactions a diffusive phase emerges with a distinct power-law decay of the time-dependent spin current Q ∝t-α . Furthermore, we investigate long-lasting current oscillations arising from the non-Markovian dynamics in the homogeneous case and find a sharp change in their frequency scaling coinciding with the triple point of the phase diagram.
Lee, Young Bok; Lee, Jun Young; Lee, Hye Jin; Yun, Seong Taek; Lee, Jong Tae; Kim, Hong Jig; Yu, Dong Soo
2014-01-01
Background Balneotherapy, although not a well-established dermatological treatment, is thought to have therapeutic properties for psoriasis and is used as an alternative treatment modality throughout the world. Objective To evaluate the mechanism underlying the therapeutic immunologic effects of thermomineral water. Methods A murine model of imiquimod-induced psoriasis-like skin inflammation was used for evaluating the therapeutic effects of balneotherapy with Hae-Un-Dae hot spring mineral water. The clinical improvements were evaluated by a dermatologist. Lesional cytokines, including interleukin (IL)-17A, IL-23, and IL-22, were quantitatively measured by real-time reverse transcriptase polymerase chain reaction. Serum levels of interferon-γ, IL-4, IL-5, and IL-17A were measured by enzyme-linked immunosorbent assay. T cell proportions in the spleen were evaluated by flow cytometry, and histopathological evaluation of the skin was also performed. Results The mineral water balneotherapy group showed faster improvement in skin erythema and scales than the distilled water bathing group. A substantial reduction was observed in the lesional mRNA levels of IL-17A and IL-23 in the mineral water group. Serum levels of IL-4 and IL-5 were significantly decreased in the mineral water group but not in the distilled water group. Normalized T cell proportions were observed after bathing. Conclusion Balneotherapy showed immunomodulatory effects in a psoriasis-like murine model. Balneotherapy suppressed lesional IL-23 and IL-17A, which are important cytokines in the pathogenesis of psoriasis. These results suggest that balneotherapy can be used as an effective and safe treatment for psoriasis. PMID:24882978
[Studies on GC fingerprint of volatile oil of Houttuynia cordata].
Yang, Bin; Wang, Ruo-Jing; Wang, Qian-Peng; Lu, Dong-Mei; Li, Hua; Xiao, Yong-Qing; Wang, Yong-Yan
2006-12-01
To establish a GC fingerprint of the volatile oil of Houttuynia cordata. The volatile oil was extracted from H. cordata by water stream distillation method, and analyzed by GC coupled with FID. 12 bathes of samples collected from different regions were analyzed; the GC fingerprint of the volatile oil of H. cordata was subsequently established. The established GC fingerprint can be used for the identification of H. cordata.
Experimental studies on islets isolation, purification and function in rats
Pang, Xinlu; Xue, Wujun; Feng, Xinshun; Tian, Xiaohui; Teng, Yan; Ding, Xiaoming; Pan, Xiaoming; Guo, Qi; He, Xiaoli
2015-01-01
To develop a simple and effective method of islet isolation and purification in rats. Collagenase P was injected into pancreatic duct followed by incubation in water bath to digest the pancreas and isolate islet, then discontinuous gravity gradient purification was used to purify the islet. The purified islets were identified by dithizone staining. The viability of islets was assessed by fluorescence staining of acridine orange (AO) and propidium iodide (PI). The function of purified islets was determined by glucose-stimulated insulin release test and transplantation of rat with streptozocin-induced diabetes. 738±193 islets were recovered after purification. The average purity was 77±13%, the viability of islets was more than 95%. When inspected by glucose stimulation, the secreted insulin concentration was 24.31±5.47 mIU/L when stimulated by low concentration glucose and 37.62±4.29 mIU/L by high concentration glucose. There was significant difference between the two phases (P<0.05). The blood sugar concentration recovered to normal level after two days in the animals with islet transplantation. In conclusion, islets can be procured with good function and shape by using the method of injecting collagenase into pancreatic duct followed by incubation in water bath and purification using discontinuous gravity gradient. PMID:26885021
Modular shipbuilding and its relevance to construction of nuclear power plants. Master's thesis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Seubert, T.W.
1988-05-01
The modern techniques of modular shipbuilding based on the Product Work Breakdown Structure as developed at the Ishikawajima-Harima Heavy Industries Co., Ltd. of Japan are examined and compared to conventional shipbuilding methods. The application of the Product Work Breakdown Structure in the building of the U.S. Navy's DDG-51 class ship at Bath Iron Works is described and compared to Japanese shipbuilding practices. Implementation of the Product Work Breakdown Structure at Avondale Shipyards, Incorporated is discussed and compared to Bath Iron Works shipbuilding practices. A proposed generic implementation of the Product Work Breakdown Structure to the modular construction of nuclear powermore » plants is described. Specific conclusions for the application of Product Work Breakdown Structure to the construction of a light water reactor nuclear power plant are discussed.« less
... Showering may help avoid possible recontamination in bath water. Change underwear and bed linen daily. This helps remove eggs. Launder in hot water. Wash bedsheets, nightclothes, underwear, washcloths and towels in ...
The effects of daily bathing on symptoms of patients with bronchial asthma
Arimoto, Yoshihito; Homma, Chie; Takeoka, Shinjiro; Fukusumi, Munehisa; Mouri, Atsuto; Hamamoto, Yoichiro
2016-01-01
Background The influence of bathing in asthma patients is not yet fully known. Objective We conducted an observational study to investigate changes in symptoms and their degree by bathing in asthmatic patients. Methods A questionnaire focusing on ever experienced bathing-induced symptom changes and their degree, as well as contributing factors, was designed and administered to asthmatic patients in the outpatient department of our institute between January 2012 and November 2013. Results Two hundred fifteen cases were recruited. In 60 cases (27.9%), asthmatic symptoms appeared, including 20 cases of chest discomfort (33.3%), 19 cases of cough (31.7%), and 21 cases of wheezing (35.0%). The triggering factors included vapor inhalation (32 cases, 53.3%), hydrostatic pressure on the thorax due to body immersion in the bathtub (26 cases, 43.3%), and sudden change of air temperature (16 cases, 26.7%). Thirty-eight cases (17.7%) experienced improvement in active asthmatic symptoms by bathing. Vapor inhalation was the most common contributing factor (34 cases, 89.5%), followed by warming of the whole body (13 cases, 34.2%). There was no relationship between asthma severity and the appearance of bathing-induced symptoms or improvement of active asthmatic symptoms by bathing. Conclusion The effects of bathing in asthmatic patients widely differed from patient to patient and their etiology includes several factors. For those who suffer from bathing-induced asthma symptoms, preventive methods, such as premedication with bronchodilators before bathing, should be established. This study is registered in the University Hospital Medical Information Network (UMIN) clinical trials registry in Japan with the registration number UMIN000015641. PMID:27141485
Sterk, Ankie; de Man, Heleen; Schijven, Jack F; de Nijs, Ton; de Roda Husman, Ana Maria
2016-11-15
Climate change is expected to influence infection risks while bathing downstream of sewage emissions from combined sewage overflows (CSOs) or waste water treatment plants (WWTPs) due to changes in pathogen influx, rising temperatures and changing flow rates of the receiving waters. In this study, climate change impacts on the surface water concentrations of Campylobacter, Cryptosporidium and norovirus originating from sewage were modelled. Quantitative microbial risk assessment (QMRA) was used to assess changes in risks of infection. In general, infection risks downstream of WWTPs are higher than downstream CSOs. Even though model outputs show an increase in CSO influxes, in combination with changes in pathogen survival, dilution within the sewage system and bathing behaviour, the effects on the infection risks are limited. However, a decrease in dilution capacity of surface waters could have significant impact on the infection risks of relatively stable pathogens like Cryptosporidium and norovirus. Overall, average risks are found to be higher downstream WWTPs compared to CSOs. Especially with regard to decreased flow rates, adaptation measures on treatment at WWTPs may be more beneficial for human health than decreasing CSO events. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
Valizadeh, Leila; Seyyedrasooli, Alehe; Zamanazadeh, Vahid; Nasiri, Khadijeh
2015-11-01
Sleep disorders are common mental disorders reported among the elderly in all countries, and with nonpharmacological interventions, they could be helped to improve their sleep quality. The aim of this study was to compare the effects of two interventions, foot reflexology and foot bath, on sleep quality in elderly people. This three-group randomized clinical trial (two experimental groups and a control group) was conducted on 69 elderly men. The two experimental groups had reflexology (n = 23) and foot bath (n = 23) interventions for 6 weeks. The reflexology intervention was done in the mornings, once a week for ten minutes on each foot. The participants in the foot bath group were asked to soak their feet in 41°C to 42°C water one hour before sleeping. The pittsburgh sleep quality index (PSQI) was completed before and after the intervention through an interview process. The results showed that the PSQI scores after intervention compared to before it in the reflexology and foot bath groups were statistically significant (P = 0.01 , P = 0.001); however, in the control group did not show a statistically significant difference (P = 0.14). In addition, the total score changes among the three groups were statistically significant (P = 0.01). Comparing the score changes of quality of sleep between the reflexology and foot bath groups showed that there was no significant difference in none of the components and the total score (P = 0.09). The two interventions had the same impact on the quality of sleep. It is suggested that the training of nonpharmacological methods to improve sleep quality such as reflexology and foot bath be included in the elderly health programs. In addition, it is recommended that the impact of these interventions on subjective sleep quality using polysomnographic recordings be explored in future research.
Elevated Bathing-Associated Disease Risks Despite Certified Water Quality: A Cohort Study
Papastergiou, Panagiotis; Mouchtouri, Varvara; Pinaka, Ourania; Katsiaflaka, Anna; Rachiotis, George; Hadjichristodoulou, Christos
2012-01-01
Bacteriological water quality criteria have been recommended to ensure bathers’ health. However, this risk-assessment approach is based mainly on routine measurements of fecal pollution indicator bacteria in seawater, and may not be adequate to protect bathers effectively. The aim of this study was to assess the risks of symptoms related to infectious diseases among bathers after exposure to seawater which was of excellent quality according to EU guidelines. This study is a cohort study recruiting bathers and non-bathers. Water samples were collected for estimating bacterial indicators. Univariable and multivariable analysis was performed to compare the risks of developing symptoms/diseases between bathers and non-bathers. A total of 3805 bathers and 572 non-bathers were included in the study. Water analysis results demonstrated excellent quality of bathing water. Significantly increased risks of symptoms related to gastrointestinal infections (OR = 3.60, 95% CI 1.28–10.13), respiratory infections (OR = 1.92, 95% CI 1.00–3.67), eye infections (OR = 2.43, 95% CI 1.27–4.63) and ear infections (OR = 17.21, 95% CI 2.42–122.34) were observed among bathers compared with non-bathers. Increased rates of medical consultation and medication use were also observed among bathers. There was evidence that bathers experienced increased morbidity compared with non-bathers though the bathing waters met bacteriological water quality criteria. These results suggest that risk assessments of recreational seawaters should not only focus on bacteriological water quality criteria. PMID:22754456
Lee, Young Bok; Kim, Su Jin; Park, Sae Mi; Lee, Kyung Ho; Han, Hyung Jin; Yu, Dong Soo; Woo, So Youn; Yun, Seong Taek; Hamm, Se-Yeong; Kim, Hong Jig; Kim, Jin-Wou
2016-04-01
Although the therapeutic mechanism of balneotherapy for atopic dermatitis has not been clarified, many atopic patients who visit thermomineral springs have shown clinical improvements. This study was aimed to evaluate the immunomodulatory effect of thermomineral water balneotherapy on the atopic dermatitis murine model. The oxazolone-induced atopic dermatitis murine model was used to evaluate the therapeutic effect of balneotherapy with Deokgu thermomineral water compared with distilled water. Histologic evaluation and confocal microscopic imaging were performed to analyze the lesional expression of cluster-of-differentiation (CD)4 and forkhead box p3 (Foxp3). Lesional mRNA expression of interleukin (IL) 33, thymic stromal lymphopoietin (TSLP), and Foxp3 was evaluated by real-time reverse transcription polymerase chain reaction. Compared with the distilled water bath group, confocal microscopic evaluation of CD4 and Foxp3 merged images showed increased expression of regulatory T cells in the thermomineral balneotherapy group. The lesional mRNA level of IL-33 showed a reduced trend in the thermomineral balneotherapy group, whereas the level of mRNA of Foxp3 was increased. TSLP showed a decreased trend in both distilled water and thermomineral water bath groups. There was a trend of reduced expression in lesional IL-33 mRNA but increased cell count of CD4(+) Foxp3(+) regulatory T cells in thermomineral balneotherapy compared with distilled water bath. Therefore, thermomineral balneotherapy can be an effective and safe adjuvant therapeutic option for atopic dermatitis.
Balneotherapy for osteoarthritis.
Verhagen, A P; Bierma-Zeinstra, S M A; Boers, M; Cardoso, J R; Lambeck, J; de Bie, R A; de Vet, H C W
2007-10-17
Balneotherapy (or spa therapy, mineral baths) for patients with arthritis is one of the oldest forms of therapy. One of the aims of balneotherapy is to soothe the pain and as a consequence to relieve patients' suffering and make them feel well. In this update we included one extra study. To assess the effectiveness of balneotherapy for patients with osteoarthritis (OA). We searched the following databases up to October 2006: EMBASE, PubMed, the Cochrane 'Rehabilitation and Related Therapies' Field database, PEDro, CENTRAL (Issue 3, 2006) and performed reference checking and communicated with authors to retrieve eligible studies. Randomised controlled trials (RCT) comparing balneotherapy with any intervention or no intervention. At least 90% of the patient population had to be diagnosed with OA. Two authors independently assessed quality and extracted data. Disagreements were solved by consensus. In the event of clinical heterogeneity or lack of data we refrained from statistical pooling. Seven trials (498 patients) were included in this review. Two studies compared spa-treatment with no treatment. One study evaluated baths as an add-on treatment to home exercises and another compared thermal water from Cserkeszölö with tap water (placebo). Three studies evaluated sulphur or Dead Sea baths with no treatment or mineral baths with tap water baths or no treatment. Only one of the trials performed an intention-to-treat analysis and two studies provided data to perform an intention-to-treat analysis ourselves. A 'quality of life' outcome was reported by one trial. We found: silver level evidence concerning the beneficial effects on pain, quality of life and analgesic intake of mineral baths compared to no treatment (SMD between 1.82 and 0.34). a statistically significant difference in pain and function of Dead Sea + sulphur versus no treatment, only at end of treatment (WMD 5.7, 95%CI 3.3 to 8.1), but not at 3 month follow-up (WMD 2.6, 95%CI -1.1 to 6.3). no statistically significant differences in pain or function at one or three months of Dead Sea baths versus no treatment (WMD 0.5, 95%CI -0.6 to 1.6) or at one or three months of sulphur baths versus no treatment (WMD 0.4, 95%CI -0.9 to 1.7). Adverse events were not measured in the included trials. We found silver level evidence (www.cochranemsk.org) concerning the beneficial effects of mineral baths compared to no treatment. Of all other balneological treatments no clear effects were found. However, the scientific evidence is weak because of the poor methodological quality and the absence of an adequate statistical analysis and data presentation. Therefore, the noted "positive findings" should be viewed with caution.
Keswani, Anisha; Oliver, David M; Gutierrez, Tony; Quilliam, Richard S
2016-07-01
Marine plastic debris is well characterized in terms of its ability to negatively impact terrestrial and marine environments, endanger coastal wildlife, and interfere with navigation, tourism and commercial fisheries. However, the impacts of potentially harmful microorganisms and pathogens colonising plastic litter are not well understood. The hard surface of plastics provides an ideal environment for opportunistic microbial colonisers to form biofilms and might offer a protective niche capable of supporting a diversity of different microorganisms, known as the "Plastisphere". This biotope could act as an important vector for the persistence and spread of pathogens, faecal indicator organisms (FIOs) and harmful algal bloom species (HABs) across beach and bathing environments. This review will focus on the existent knowledge and research gaps, and identify the possible consequences of plastic-associated microbes on human health, the spread of infectious diseases and bathing water quality. Copyright © 2016 Elsevier Ltd. All rights reserved.
Gel-Filled Holders For Ultrasonic Transducers
NASA Technical Reports Server (NTRS)
Companion, John A.
1992-01-01
In new technique, ultrasonic transducer embedded in rubbery, castable, low-loss gel to enable transducer to "look" into surface of test object or human body at any desired angle. Composed of solution of water and ethylene glycol in collagen matrix. Provides total contact of water bath, also used on bodies or objects too large for water baths, even if moving. Also provides look angles of poly(methyl methacrylate) angle block with potential of reduced acoustic impedance and refraction. Custom-tailored to task at hand, and gel sufficiently inexpensive to be discarded upon completion. Easy to couple ultrasound in and out of gel, minimizing losses and artifacts of other types of standoffs employed in ultrasonic testing.
Wash and Wean: Bathing Patients Undergoing Weaning Trials During Prolonged Mechanical Ventilation
Happ, Mary Beth; Tate, Judith A.; Swigart, Valerie A.; DiVirgilio-Thomas, Dana; Hoffman, Leslie A.
2010-01-01
BACKGROUND Bathing is a fundamental nursing care activity performed for or with the self-assistance of critically ill patients. Few studies address caregiver and/or patient-family perspectives about bathing activity during weaning from prolonged mechanical ventilation. OBJECTIVE To describe practices and beliefs about bathing patients during weaning from prolonged mechanical ventilation (PMV). METHODS Secondary analysis of qualitative data (observational field notes, interviews, and clinical record review) from a larger ethnographic study involving 30 patients weaning from PMV and the clinicians who cared for them using basic qualitative description. RESULTS Bathing, hygiene, and personal care were highly valued and equated with “good” nursing care by families and nurses. Nurses and respiratory therapists reported “working around” bath time and promoted conducting weaning trials before or after bathing. Patients were nevertheless bathed during weaning trials despite clinicians expressed concerns for energy conservation. Clinicians’ recognized individual patient response to bathing during PMV weaning trials. CONCLUSION Bathing is a central care activity for PMV patients and a component of daily work processes in the ICU. Bathing requires assessment of patient condition and activity tolerance and nurse-respiratory therapist negotiation and accommodation with respect to the initiation and/or continuation of PMV weaning trials during bathing. Further study is needed to validate the impact (or lack of impact) of various timing strategies for bathing PMV patients. PMID:20561877
Water-Based Peeling of Thin Hydrophobic Films
NASA Astrophysics Data System (ADS)
Khodaparast, Sepideh; Boulogne, François; Poulard, Christophe; Stone, Howard A.
2017-10-01
Inks of permanent markers and waterproof cosmetics create elastic thin films upon application on a surface. Such adhesive materials are deliberately designed to exhibit water-repellent behavior. Therefore, patterns made up of these inks become resistant to moisture and cannot be cleaned by water after drying. However, we show that sufficiently slow dipping of such elastic films, which are adhered to a substrate, into a bath of pure water allows for complete removal of the hydrophobic coatings. Upon dipping, the air-water interface in the bath forms a contact line on the substrate, which exerts a capillary-induced peeling force at the edge of the hydrophobic thin film. We highlight that this capillary peeling process is more effective at lower velocities of the air-liquid interface and lower viscosities. Capillary peeling not only removes such thin films from the substrate but also transfers them flawlessly onto the air-water interface.
Hashiguchi, Nobuko; Tochihara, Yutaka
2009-02-01
In the present study we investigated the effects of low relative humidity (RH) and high air velocity (VA) on physiological and subjective responses after bathing in order to present the evidence for required nursing intervention after bathing. Eight healthy male subjects participated in this experiment. There were four thermal conditions which combined RH (20% of 60%) and VA (low: less than 0.2 m/s or high: from 0.5 to 0.7 m/s). After taking a tub bath, subjects sat for 80 min in the test room under each condition. In addition, one condition under which the subjects were exposed to 20% RH and high VA condition for 80 min without bathing condition was conducted. A decrease in mean skin temperature (T sk), dryness of the skin and eyes were observed, though thermal comfort and warmth retained, due to spending time after bathing in a low RH and high VA environment, compared to the condition without bathing. Moreover, dryness of the skin, a decrease in hydration of the skin and an increase in transepidermal water loss (TEWL) after bathing were significantly affected by RH levels, on the other hand subjective coolness, discomfort and perception of dryness in the eye were significantly affected by VA levels. The decrease in T sk after bathing was significantly affected by both RH and VA. From our findings we concluded that low RH and high VA have negative effects on humans after bathing, for example a decrease in body temperature and dryness of the skin and eyes. Moreover, it was indicated that the negative effects could be kept to a minimum and thermal comfort remain higher, if RH and VA levels were controlled within the optimum ranges.
Dust-bathing behavior of laying hens in enriched colony housing systems and an aviary system
Louton, H.; Bergmann, S.; Reese, S.; Erhard, M. H.; Rauch, E.
2016-01-01
The dust-bathing behavior of Lohmann Selected Leghorn hens was compared in 4 enriched colony housing systems and in an aviary system. The enriched colony housing systems differed especially in the alignment and division of the functional areas dust bath, nest, and perches. Forty-eight-hour video recordings were performed at 3 time-points during the laying period, and focal animal sampling and behavior sampling methods were used to analyze the dust-bathing behavior. Focal animal data included the relative fractions of dust-bathing hens overall, of hens bathing in the dust-bath area, and of those bathing on the wire floor throughout the day. Behavior data included the number of dust-bathing bouts within a predefined time range, the duration of 1 bout, the number of and reasons for interruptions, and the number of and reasons for the termination of dust-bathing bouts. Results showed that the average duration of dust bathing varied between the 4 enriched colony housing systems compared with the aviary system. The duration of dust-bathing bouts was shorter than reported under natural conditions. A positive correlation between dust-bathing activity and size of the dust-bath area was observed. Frequently, dust baths were interrupted and terminated by disturbing influences such as pecking by other hens. This was especially observed in the enriched colony housing systems. In none of the observed systems, neither in the enriched colony housing nor in the aviary system, were all of the observed dust baths terminated “normally.” Dust bathing behavior on the wire mesh rather than in the provided dust-bath area generally was observed at different frequencies in all enriched colony housing systems during all observation periods, but never in the aviary system. The size and design of the dust-bath area influenced the prevalence of dust-bathing behavior in that small and subdivided dust-bath areas reduced the number of dust-bathing bouts but increased the incidence of sham dust bathing on the wire mesh. PMID:27044875
Human recreational exposure to antibiotic resistant bacteria in coastal bathing waters.
Leonard, Anne F C; Zhang, Lihong; Balfour, Andrew J; Garside, Ruth; Gaze, William H
2015-09-01
Infections caused by antibiotic resistant bacteria (ARB) are associated with poor health outcomes and are recognised globally as a serious health problem. Much research has been conducted on the transmission of ARB to humans. Yet the role the natural environment plays in the spread of ARB and antibiotic resistance genes is not well understood. Antibiotic resistant bacteria have been detected in natural aquatic environments, and ingestion of seawater during water sports is one route by which many people could be directly exposed. The aim was to estimate the prevalence of resistance to one clinically important class of antibiotics (third-generation cephalosporins (3GCs)) amongst Escherichia coli in coastal surface waters in England and Wales. Prevalence data was used to quantify ingestion of 3GC-resistant E. coli (3GCREC) by people participating in water sports in designated coastal bathing waters. A further aim was to use this value to derive a population-level estimate of exposure to these bacteria during recreational use of coastal waters in 2012. The prevalence of 3GC-resistance amongst E. coli isolated from coastal surface waters was estimated using culture-based methods. This was combined with the density of E. coli reported in designated coastal bathing waters along with estimations of the volumes of water ingested during various water sports reported in the literature to calculate the mean number of 3GCREC ingested during different water sports. 0.12% of E. coli isolated from surface waters were resistant to 3GCs. This value was used to estimate that in England and Wales over 6.3 million water sport sessions occurred in 2012 that resulted in the ingestion of at least one 3GCREC. Despite the low prevalence of resistance to 3GCs amongst E. coli in surface waters, there is an identifiable human exposure risk for water users, which varies with the type of water sport undertaken. The relative importance of this exposure is likely to be greater in areas where a large proportion of the population enjoys water sports. Millions of water sport sessions occurred in 2012 that were likely to have resulted in people ingesting E. coli resistant to a single class of antibiotics (3GCs). However, this is expected to be a significant underestimate of recreational exposure to all ARB in seawater. This is the first study to use volumes of water ingested during different water sports to estimate human exposure to ARB. Further work needs to be done to elucidate the health implications and clinical relevance of exposure to ARB in both marine and fresh waters in order to fully understand the risk to public health. Copyright © 2015 Elsevier Ltd. All rights reserved.
Salvaging and Conserving Water Damaged Photographic Materials
NASA Astrophysics Data System (ADS)
Suzuki, Ryuji
Degradation of water damaged photographic materials is discussed; the most vulnerable elements are gelatin layers and silver image. A simple and inexpensive chemical treatment is proposed, consisting of a bath containing a gelatin-protecting biocide and a silver image protecting agent. These ingredients were selected among those used in manufacturing of silver halide photographic emulsions or processing chemicals. Experiments confirmed that this treatment significantly reduced oxidative attacks to silver image and bacterial degradation of gelatin layers. The treated material was also stable under intense light fading test. Method of hardening gelatin to suppress swelling is also discussed.
Remote Sensing of Salinity: The Dielectric Constant of Sea Water
NASA Technical Reports Server (NTRS)
LeVine, David M.; Lang, R.; Utku, C.; Tarkocin, Y.
2011-01-01
Global monitoring of sea surface salinity from space requires an accurate model for the dielectric constant of sea water as a function of salinity and temperature to characterize the emissivity of the surface. Measurements are being made at 1.413 GHz, the center frequency of the Aquarius radiometers, using a resonant cavity and the perturbation method. The cavity is operated in a transmission mode and immersed in a liquid bath to control temperature. Multiple measurements are made at each temperature and salinity. Error budgets indicate a relative accuracy for both real and imaginary parts of the dielectric constant of about 1%.
Potential sources of bacteriological pollution for two bays with marinas in Trinidad.
Bullock, Christine Ann; Moonesar, Indar
2005-05-01
Welcome Bay and Chaguaramas Bay in the northwest peninsula of Trinidad contain large marinas and smaller sections of bathing beaches. Bacteriological surveys were conducted at both bays to assess water quality and to determine potential sources of pollution. These surveys were conducted during the wet season of 1996 and the dry season of 1997. Eleven sample stations were established at Welcome Bay and 12 at Chaguaramas Bay. Freshwater samples were collected from rivers and drains within the survey area. Marine water samples were collected from marinas, bathing beaches and inshore and outer areas at both bays. Five water samples were collected from each sampling station during the wet season of 1996 and six during the dry season of 1997. The membrane filter technique was used to determine faecal coliform and Escherichia coli levels in all samples. There was a seasonal effect on water quality, with significantly higher faecal coliform levels in the wet season, when water quality was not in compliance with international standards. This represents a potential health risk in bathing areas. Water quality was better at the outer area of both bays. Water quality at the inner bay areas was most likely adversely affected by land-based sources of pollution identified in this study. These sources include three drains and two rivers, which discharged into the bays. Yachts were apparently not a source of sewage pollution: there was no significant relationship between yacht number and faecal coliform levels.
Microbial detection method based on sensing molecular hydrogen
NASA Technical Reports Server (NTRS)
Wilkins, J. R.; Stoner, G. E.; Boykin, E. H.
1974-01-01
An approach involving the measurement of hydrogen evolution by test organisms was used to detect and enumerate various members of the Enterobacteriaceae group. The experimental setup for measuring hydrogen evolution consisted of a test tube containing two electrodes plus broth and organisms. The test tube was kept in a water bath at a temperature of 35 C. It is pointed out that the hydrogen-sensing method, coupled with the pressure transducer technique reported by Wilkins (1974) could be used in various experiments in which gas production by microorganisms is being measured.
Stress and Fatigue Management Using Balneotherapy in a Short-Time Randomized Controlled Trial.
Rapolienė, Lolita; Razbadauskas, Artūras; Sąlyga, Jonas; Martinkėnas, Arvydas
2016-01-01
Objective. To investigate the influence of high-salinity geothermal mineral water on stress and fatigue. Method. 180 seamen were randomized into three groups: geothermal (65), music (50), and control (65). The geothermal group was administered 108 g/L salinity geothermal water bath for 2 weeks five times a week. Primary outcome was effect on stress and fatigue. Secondary outcomes were the effect on cognitive function, mood, and pain. Results. The improvements after balneotherapy were a reduction in the number and intensity of stress-related symptoms, a reduction in pain and general, physical, and mental fatigue, and an improvement in stress-related symptoms management, mood, activation, motivation, and cognitive functions with effect size from 0.8 to 2.3. In the music therapy group, there were significant positive changes in the number of stress symptoms, intensity, mood, pain, and activity with the effect size of 0.4 to 1.1. The researchers did not observe any significant positive changes in the control group. The comparison between the groups showed that balneotherapy was superior to music therapy and no treatment group. Conclusions. Balneotherapy is beneficial for stress and fatigue reduction in comparison with music or no therapy group. Geothermal water baths have a potential as an efficient approach to diminish stress caused by working or living conditions.
Stress and Fatigue Management Using Balneotherapy in a Short-Time Randomized Controlled Trial
Razbadauskas, Artūras; Sąlyga, Jonas; Martinkėnas, Arvydas
2016-01-01
Objective. To investigate the influence of high-salinity geothermal mineral water on stress and fatigue. Method. 180 seamen were randomized into three groups: geothermal (65), music (50), and control (65). The geothermal group was administered 108 g/L salinity geothermal water bath for 2 weeks five times a week. Primary outcome was effect on stress and fatigue. Secondary outcomes were the effect on cognitive function, mood, and pain. Results. The improvements after balneotherapy were a reduction in the number and intensity of stress-related symptoms, a reduction in pain and general, physical, and mental fatigue, and an improvement in stress-related symptoms management, mood, activation, motivation, and cognitive functions with effect size from 0.8 to 2.3. In the music therapy group, there were significant positive changes in the number of stress symptoms, intensity, mood, pain, and activity with the effect size of 0.4 to 1.1. The researchers did not observe any significant positive changes in the control group. The comparison between the groups showed that balneotherapy was superior to music therapy and no treatment group. Conclusions. Balneotherapy is beneficial for stress and fatigue reduction in comparison with music or no therapy group. Geothermal water baths have a potential as an efficient approach to diminish stress caused by working or living conditions. PMID:27051455
Ahmed, S A; Hoque, B A; Mahmud, A
1998-09-01
Although Bangladesh has achieved remarkable success in extending the availability of hand pumped and piped water, unsafe water is still ingested. This brief study attempted to assess water management practices in rural and urban homes in Bangladesh so as to establish the routes by which unsafe water is ingested, to examine methods of collection and storage, and determine why unsafe water sources are used when unsafe supplies are available. Forty-eight rural and forty-five urban slum households were studied. Observations, interviews and water quality investigations were conducted. The results show that the respondents were aware that hand pump/tap water is safe and took care to use these safe sources for drinking purposes. However, they continued to use surface water for non-drinking activities such as bathing, washing and rinsing their mouths. Reasons were given that it was a traditional practice to bathe in surface water and was more enjoyable. One of the reasons given for not using hand pumped water to wash clothing and food was that such groundwater caused staining. Bacteriological results from such ingested water showed the quality, especially in rural areas, to be poor. Results also showed the internal surfaces of the base of storage containers to be heavily contaminated with bacteria. This showed that water that was safe when it was first drawn would became contaminated during storage. This study had a limited scope; much further research is needed to find what determines and how water becomes contaminated in containers. These factors include how to reduce contamination of water, in particular the relationship between growth of bacteria in stored water and the material from which the container is made and how to improve the overall quality of water. On the management side, studies could be conducted as to how to improve people's understanding of the use of water for domestic purposes and its safe management.
Coyer, Fiona M; O'Sullivan, Judy; Cadman, Nicola
2011-08-01
The provision of the patient bed-bath is a fundamental nursing care activity yet few quantitative data and no qualitative data are available on registered nurses' (RNs) clinical practice in this domain in the intensive care unit (ICU). The aim of this study was to describe ICU RNs current practice with respect to the timing, frequency and duration of the patient bed-bath and the cleansing and emollient agents used. The study utilised a two-phase sequential explanatory mixed method design. Phase one used a questionnaire to survey RNs and phase two employed semi-structured focus group (FG) interviews with RNs. Data was collected over 28 days across four Australian metropolitan ICUs. Ethical approval was granted from the relevant hospital and university human research ethics committees. RNs were asked to complete a questionnaire following each episode of care (i.e. bed-bath) and then to attend one of three FG interviews: RNs with less than 2 years ICU experience; RNs with 2-5 years ICU experience; and RNs with greater than 5 years ICU experience. During the 28-day study period the four ICUs had 77.25 beds open. In phase one a total of 539 questionnaires were returned, representing 30.5% of episodes of patient bed-baths (based on 1767 bed occupancy and one bed-bath per patient per day). In 349 bed-bath episodes 54.7% patients were mechanically ventilated. The bed-bath was given between 02.00 and 06.00h in 161 episodes (30%), took 15-30min to complete (n=195, 36.2%) and was completed within the last 8h in 304 episodes (56.8%). Cleansing agents used were predominantly pH balanced soap or liquid soap and water (n=379, 71%) in comparison to chlorhexidine impregnated sponges/cloths (n=86, 16.1%) or other agents such as pre-packaged washcloths (n=65, 12.2%). In 347 episodes (64.4%) emollients were not applied after the bed-bath. In phase two 12 FGs were conducted (three FGs at each ICU) with a total of 42 RN participants. Thematic analysis of FG transcripts across the three levels of RN ICU experience highlighted a transition of patient hygiene practice philosophy from shades of grey - falling in line for inexperienced clinicians to experienced clinicians concrete beliefs about patient bed-bath needs. This study identified variation in process and products used in patient hygiene practices in four ICUs. Further study to improve patient outcomes is required to determine the appropriate timing of patient hygiene activities and cleansing agents used to improve skin integrity. Copyright © 2010 Australian College of Critical Care Nurses Ltd. Published by Elsevier Ltd. All rights reserved.
Method for separating water soluble organics from a process stream by aqueous biphasic extraction
Chaiko, David J.; Mego, William A.
1999-01-01
A method for separating water-miscible organic species from a process stream by aqueous biphasic extraction is provided. An aqueous biphase system is generated by contacting a process stream comprised of water, salt, and organic species with an aqueous polymer solution. The organic species transfer from the salt-rich phase to the polymer-rich phase, and the phases are separated. Next, the polymer is recovered from the loaded polymer phase by selectively extracting the polymer into an organic phase at an elevated temperature, while the organic species remain in a substantially salt-free aqueous solution. Alternatively, the polymer is recovered from the loaded polymer by a temperature induced phase separation (cloud point extraction), whereby the polymer and the organic species separate into two distinct solutions. The method for separating water-miscible organic species is applicable to the treatment of industrial wastewater streams, including the extraction and recovery of complexed metal ions from salt solutions, organic contaminants from mineral processing streams, and colorants from spent dye baths.
[Magnetotherapy in the combined health resort-based treatment of irritated bowel syndrome].
Kaĭsinova, A S; Osipov, Iu S; Litvinova, M A; Prosol'chenko, A V
2011-01-01
The authors describe a combined method for the treatment of irritated bowel syndrome with the use of magnetotherapy, drinking mineral waters, and radon baths. It was shown that prescription of preformed physical factors improves the psycho-emotional status of the patients due to normalization of the motor-evacuative function of the gastrointestinal tract. The overall result of this therapeutic modality is the improvement of the quality of life of the patients.
Antimycobacterial potential of the juniper berry essential oil in tap water.
Peruč, Dolores; Gobin, Ivana; Abram, Maja; Broznić, Dalibor; Svalina, Tomislav; Štifter, Sanja; Staver, Mladenka Malenica; Tićac, Brigita
2018-03-01
Mycobacterium avium complex-related diseases are often associated with poorly maintained hot water systems. This calls for the development of new control strategies. The aim of this study was to investigate the activity of essential oils (EOs) from the Mediterranean plants, common juniper, immortelle, sage, lavandin, laurel, and white cedar against Mycobacterium avium ssp. avium, Mycobacterium intracellulare, and Mycobacterium gordonae in culturing broth and freshwater as their most common habitat. To do that, we developed a new method of water microdilution to determine their minimal effective concentrations (MEC). The most active EO was the one from the common juniper with the MEC of 1.6 mg mL-1. Gas chromatography / mass spectrometry the juniper EO identified monoterpenes (70.54 %) and sesquiterpenes (25.9 %) as dominant component groups. The main monoterpene hydrocarbons were α-pinene, sabinene, and β-pinene. The juniper EO significantly reduced the cell viability of M. intracellulare and M. gordonae at MEC, and of M. avium at 2xMEC. Microscopic analysis confirmed its inhibitory effect by revealing significant morphological changes in the cell membrane and cytoplasm of all three bacteria. The mode of action of the juniper EO on the cell membrane was confirmed by a marked leakage of intracellular material. Juniper EO has a great practical potential as a complementary or alternative water disinfectant in hot water systems such as baths, swimming pools, spa pools, hot tubs, or even foot baths/whirlpools.
Investigation of coercivity for electroplated Fe-Ni thick films
NASA Astrophysics Data System (ADS)
Yanai, T.; Eguchi, K.; Koda, K.; Kaji, J.; Aramaki, H.; Takashima, K.; Nakano, M.; Fukunaga, H.
2018-05-01
We have already reported Fe-Ni firms with good soft magnetic properties prepared by using an electroplating method. In our previous studies, we prepared the Fe-Ni films from citric-acid-based baths (CA-baths) and ammonium-chloride-based ones (AC-baths), and confirmed that the coercivity for the AC-baths was lower than that for the CA-baths. In the present study, we investigated reasons for the lower coercivity for the AC-baths to further improve the soft magnetic properties. From an observation of magnetic domains of the Fe22Ni78 films, we found that Fe22Ni78 film for AC-bath had a magnetic anisotropy in the width direction, and also found that the coercivity in the width direction was lower than the longitudinal one for the AC-bath. As an annealing for a stress relaxation in the films reduced the difference in the coercivity, we considered that the anisotropy is attributed to the magneto-elastic effect.
Karpukhin, I V; Li, A A; Gusev, M A
2009-01-01
The paper reports a review of up-to-date methods for the use of white turpentine bath emulsion and yellow turpentine solution in the treatment of chronic prostatitis complicated by excretory pathospermia. The results of bath therapy are presented. It is shown that the efficiency of white turpentine bath emulsion amounted to 69.7% compared with 88.3% in patients treated with the use of yellow turpentine solution.
Martínez-Reséndez, Michel Fernando; Garza-González, Elvira; Mendoza-Olazaran, Soraya; Herrera-Guerra, Alexis; Rodríguez-López, Juan Manuel; Pérez-Rodriguez, Edelmiro; Mercado-Longoria, Roberto; Camacho-Ortiz, Adrián
2014-07-01
Up to 25% of all nosocomial infections (NIs) develop in critically ill patients. Our objective was to evaluate chlorhexidine (CHX) bathing and hand hygiene (HH) compliance in the reduction of NIs in the intensive care unit. The study comprised three 6-month periods: preintervention (PIP; soap/water bathing), intervention (IP; bathing with CHX-impregnated wipes), and postintervention (PoIP; soap/water bathing). An HH program was implemented during the IP and PoIP. Primary outcomes were global and specific NI rates. A total of 1007 patients were included. Infection rates per 100 discharges were higher in the PIP compared with the IP and also higher in the PoIP compared with the IP (P = .0004 and .0109, respectively). Global infection rates per 1000 hospital-days were higher in the PIP than in the IP (P = .0268). The rates of ventilator-associated pneumonia (VAP) and catheter-associated urinary tract infection (CAUTI) were higher in the PIP than in the IP (P = .036 and .0001, respectively). Isolation of Acinetobacter baumannii from VAP specimens (P = .0204) and isolation of Candida spp from CAUTI specimens (P = .0005) decreased as well. The combined intervention reduced global and specific infection rates, including rates of VAP associated with A baumannii and CAUTI associated with Candida spp. Copyright © 2014 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.
Head-cloaca controlled current stunning: assessment of brain and heart activity and meat quality.
Lambooij, E; Reimert, H G M; Workel, L D; Hindle, V A
2012-01-01
1. Behavioural and neural responses of 65 broilers to head-to-cloaca electrical stunning were evaluated and meat quality was assessed on two groups of 25 broilers stunned either head to cloaca, or in a conventional water bath method. 2. On the EEG recordings, a general epileptiform insult was observed when applying a current of 100 mA (100 Hz) or 70 mA (70 Hz) for 1·5 s. This general epileptiform insult shows a tonic, clonic and exhaustion phase followed by spikes of alpha, beta, theta and delta waves with duration of on average 34 ± 12 s and 39 ± 23 s respectively. These birds may have been unconscious for 20 s or longer, according to the correlation dimension analyses. 3. The heart rate decreased significantly (P < 0·05) after stunning and recovered after 60 s. 4. Within a confidence limit of 95%, taking into account the number of animals with a reliable EEG, the chance of an effective stun of all broilers lies between 0·9 and 1·0 with a current of 70 mA (100 Hz for 1·5 s; n = 28) and with 100 mA (100 Hz for 1·5 s; n = 27). 5. The shear force of breast fillets was slightly lower (P < 0·01) 4 d post mortem compared with the conventional water bath stunned group (set at 100 mA, 100 Hz for 10 s). The percentage of fillets and legs without blood splashes was higher, and the percentage with severe blood splashes lower-to-none, for carcases stunned head-cloaca. 6. It can be concluded that broilers are effectively stunned with the head-cloaca method by using a controlled current of 70 mA or 100 mA for 1·5 s. The fillets and legs of bird stunned head-cloaca showed fewer blood splashes in the muscles compared with birds stunned in a conventional water bath.
Low-density microcellular foam and method of making same
Rinde, James A.
1977-01-01
Low-density microcellular foam having a cell size of not greater than 2 .mu.m and method of making by dissolving cellulose acetate in an acetone-based solvent, gelling the solution in a water bath maintained at 0.degree.-10.degree. C for a selected period of time to allow impurities to diffuse out, freezing the gel, and then freeze-drying wherein water and solvents sublime and the gel structure solidifies into low-density microcellular foam. The foam has a density of 0.065 to 0.6.times.10.sup.3 kg/m.sup.3 and cell size of about 0.3 to 2 .mu.m. The small cell size foam is particularly applicable for encapsulation of laser targets.
Method of making a cellulose acetate low density microcellular foam
Rinde, James A.
1978-01-01
Low-density microcellular foam having a cell size of not greater than 2 .mu.m and method of making by dissolving cellulose acetate in an acetone-based solvent, gelling the solution in a water bath maintained at 0-10.degree. C for a selected period of time to allow impurities to diffuse out, freezing the gel, and then freeze-drying wherein water and solvents sublime and the gel structure solidifies into low-density microcellular foam. The foam has a density of 0.065 to 0.6.times.10.sup.3 kg/m.sup.3 and cell size of about 0.3 to 2 .mu.m. The small cell size foam is particularly adaptable for encapsulation of laser targets.
A Third Generation Water Bath Based Blackbody Source
Fowler, Joel B.
1995-01-01
A third generation water bath based black-body source has been designed and constructed in the Radiometric Physics Division at the National Institute of Standards and Technology, Gaithersburg, MD. The goal of this work was to design a large aperture blackbody source with improved temporal stability and reproducibility compared with earlier designs, as well as improved ease of use. These blackbody sources operate in the 278 K to 353 K range with water temperature combined standard uncertainties of 3.5 mK to 7.8 mK. The calculated emissivity of these sources is 0.9997 with a relative standard uncertainty of 0.0003. With a 50 mm limiting aperture at the cavity; entrance, the emissivity increases to 0.99997. PMID:29151763
Maintenance and preservation of ectomycorrhizal and arbuscular mycorrhizal fungi.
Lalaymia, Ismahen; Cranenbrouck, Sylvie; Declerck, Stéphane
2014-07-01
Short- to long-term preservation of mycorrhizal fungi is essential for their in-depth study and, in the case of culture collections, for safeguarding their biodiversity. Many different maintenance/preservation methods have been developed in the last decades, from soil- and substrate-based maintenance to preservation methods that reduce (e.g., storage under water) or arrest (e.g., cryopreservation) growth and metabolism; all have advantages and disadvantages. In this review, the principal methods developed so far for ectomycorrhizal and arbuscular mycorrhizal fungi are reported and described given their distinct biology/ecology/evolutionary history. Factors that are the most important for their storage are presented and a protocol proposed which is applicable, although not generalizable, for the long-term preservation at ultra-low temperature of a large panel of these organisms. For ECM fungi, isolates should be grown on membranes or directly in cryovials until the late stationary growth phase. The recommended cryopreservation conditions are: a cryoprotectant of 10% glycerol, applied 1-2 h prior to cryopreservation, a slow cooling rate (1 °C min(-1)) until storage below -130 °C, and fast thawing by direct plunging in a water bath at 35-37 °C. For AMF, propagules (i.e., spores/colonized root pieces) isolated from cultures in the late or stationary phase of growth should be used and incorporated in a carrier (i.e., soil or alginate beads), preferably dried, before cryopreservation. For in vitro-cultured isolates, 0.5 M trehalose should be used as cryoprotectant, while isolates produced in vivo can be preserved in dried soil without cryoprotectant. A fast cryopreservation cooling rate should be used (direct immersion in liquid nitrogen or freezing at temperatures below -130 °C), as well as fast thawing by direct immersion in a water bath at 35 °C.
The effects of footbath on sleep among the older adults in nursing home: A quasi-experimental study.
Kim, Hyun-Joo; Lee, Yaelim; Sohng, Kyeong-Yae
2016-06-01
To examine the long-term effects of foot-bathing therapy, using different water temperatures, on the sleep quality of older adults living in nursing homes. A quasi-experimental study design with non-equivalent control group. Thirty participants were recruited from a nursing home in Gyeong-gi Province, South Korea. The participants were randomly assigned to experimental, placebo, and control groups. The foot-bathing therapy was performed for 30min daily for four weeks. Water at 40°C was used for the experimental group, while water at 36.5°C was used for the placebo group. The control group did not receive any intervention. The participants' sleep patterns (total sleep amount, sleep efficiency, and sleep latency) and sleep-disturbed behaviors were compared based on group, using actigraphy and a sleep disorder inventory. The total amount of sleep and sleep efficiency were significantly different for the experimental group, especially those with poor sleep quality. There were no differences in sleep latency or sleep-disturbed behaviors among the groups. The long-term effect of the therapy decreased in the third week of the therapy. Daily, 30-min foot-bathing therapy sessions with water at 40°C were effective in improving sleep quality for older adults. The therapy was more effective for participants with poor sleep quality at baseline assessment than those with relatively good sleep quality. The long-term effects of foot-bathing therapy decreased three weeks after initiation; therefore, it might be desirable to deliver the therapy for two weeks, pause it for a week, and then resume it. Copyright © 2016 Elsevier Ltd. All rights reserved.
The Mechanism of Isotonic Water Transport
Diamond, Jared M.
1964-01-01
The mechanism by which active solute transport causes water transport in isotonic proportions across epithelial membranes has been investigated. The principle of the experiments was to measure the osmolarity of the transported fluid when the osmolarity of the bathing solution was varied over an eightfold range by varying the NaCl concentration or by adding impermeant non-electrolytes. An in vitro preparation of rabbit gall bladder was suspended in moist oxygen without an outer bathing solution, and the pure transported fluid was collected as it dripped off the serosal surface. Under all conditions the transported fluid was found to approximate an NaCl solution isotonic to whatever bathing solution used. This finding means that the mechanism of isotonic water transport in the gall bladder is neither the double membrane effect nor co-diffusion but rather local osmosis. In other words, active NaCl transport maintains a locally high concentration of solute in some restricted space in the vicinity of the cell membrane, and water follows NaCl in response to this local osmotic gradient. An equation has been derived enabling one to calculate whether the passive water permeability of an organ is high enough to account for complete osmotic equilibration of actively transported solute. By application of this equation, water transport associated with active NaCl transport in the gall bladder cannot go through the channels for water flow under passive conditions, since these channels are grossly too impermeable. Furthermore, solute-linked water transport fails to produce the streaming potentials expected for water flow through these passive channels. Hence solute-linked water transport does not occur in the passive channels but instead involves special structures in the cell membrane, which remain to be identified. PMID:14212146
Nagy, Katalin; Berhés, István; Kovács, Tibor; Kávási, Norbert; Somlai, János; Bender, Tamás
2009-08-01
Radon bath is a well-established modality of balneotherapy for the management of degenerative musculoskeletal disorders. The present study was conducted to ascertain whether baths of relatively low (80 Bq/l) radon concentration have any influence on the functioning of the endocrine system. In the study, a non-randomized pilot study, 27 patients with degenerative musculoskeletal disorders received 30-min radon baths (of 31-32 degrees C temperature and 80 Bq/l average radon concentration) daily, for 15 days. Twenty-five patients with matching pathologies were subjected to balneotherapy according to the same protocol, using thermal water with negligible radon content (6 Bq/l). Serum thyroid stimulating hormone, prolactin, cortisol, adrenocorticotropic hormone, and dehydroepiandrosterone levels were measured before and after a balneotherapy course of 15 sessions. Comparison of the accumulated data using the Wilcoxon test did not reveal any significant difference between pre- and post-treatment values or between the two patient groups. It is noted that while the beneficial effects of balneotherapy with radon-containing water on degenerative disorders is widely known, only few data have been published in the literature on its effect on endocrine functions. The present study failed to demonstrate any substantial effect of thermal water with relatively low radon content on the functioning of the endocrine system.
NASA Astrophysics Data System (ADS)
Faka, M.; Christodoulou, S.; Abate, D.; Ioannou, C.; Hermon, S.
2017-08-01
Roman baths represented a popular social practice of everyday life, cited in numerous literary sources and testified by ample archaeological remains all over the Roman Empire. Although regional studies have contributed extensively to our knowledge about how baths functioned and what was their social role in various regions of the Mediterranean, their study in Cyprus is yet to be developed. Moreover, despite the increasing availability of devices and techniques for 3D documentation, various characteristics, especially in relation to the heating and water supply system of the baths, were omitted and were not properly and accurately documented. The pilot case study outlined in this paper presents the 3D documentation of the Roman bath, excavated in the 1950s, within the area of the Sanctuary of Apollo Hylates at Kourion (Limassol district). The creation of an accurate 3D model of the documented area through image and range based techniques combined with topographic data, allows the detailed analysis of architectural elements and their decorative features. At the same time, it enables accurate measurements of the site, which are used as input for the archaeological interpretation and virtual reconstruction of the original shape of the bath. In addition, this project aims to answer a number of archaeological research questions related to Roman baths such as their architectural features, function mode, and technological elements related to heating techniques.
Conjugate gradient heat bath for ill-conditioned actions.
Ceriotti, Michele; Bussi, Giovanni; Parrinello, Michele
2007-08-01
We present a method for performing sampling from a Boltzmann distribution of an ill-conditioned quadratic action. This method is based on heat-bath thermalization along a set of conjugate directions, generated via a conjugate-gradient procedure. The resulting scheme outperforms local updates for matrices with very high condition number, since it avoids the slowing down of modes with lower eigenvalue, and has some advantages over the global heat-bath approach, compared to which it is more stable and allows for more freedom in devising case-specific optimizations.
Acoustic bubble removal method
NASA Technical Reports Server (NTRS)
Trinh, E. H.; Elleman, D. D.; Wang, T. G. (Inventor)
1983-01-01
A method is described for removing bubbles from a liquid bath such as a bath of molten glass to be used for optical elements. Larger bubbles are first removed by applying acoustic energy resonant to a bath dimension to drive the larger bubbles toward a pressure well where the bubbles can coalesce and then be more easily removed. Thereafter, submillimeter bubbles are removed by applying acoustic energy of frequencies resonant to the small bubbles to oscillate them and thereby stir liquid immediately about the bubbles to facilitate their breakup and absorption into the liquid.
Comparison of urinary excretion of radon from the human body before and after radon bath therapy.
Kávási, Norbert; Kovács, Tibor; Somlai, János; Jobbágy, Viktor; Nagy, Katalin; Deák, Eszter; Berhés, István; Bender, Tamás; Ishikawa, Tetsuo; Tokonami, Shinji
2011-07-01
Theoretically, the human body absorbs radon through the lungs and the skin and excretes it through the lungs and the excretory organs during radon bath therapy. To check this theory, the radon concentrations in urine samples were compared before and after radon bath therapy. During the therapy, the geometric mean (GM) and the geometric standard deviation of the radon concentration in air and in the bath water were 979 Bq m(-3), 1.58 and 73.6 Bq dm(-3), 1.1, respectively. Since radon was detected in each urine sample (GM around 3.0 Bq dm(-3)), urinary excretion of radon was confirmed. The results of this study can neither reject nor confirm the hypothesis of radon absorption through the skin. A 15 times higher increment of inhaled radon level did not cause significant changes in radon of urine samples.
Ostoich, Marco; Aimo, Emilia; Fassina, Daniel; Barbaro, Jvan; Vazzoler, Marina; Soccorso, Corrado; Rossi, Chiara
2011-02-01
This paper presents a preliminary study of the water profile with reference to microbiological parameters, required by Directive 2006/07/EC (European Community 2006) concerning the management of bathing water quality, in the coastal belt of the Province of Venice (Italy, Northern Adriatic Sea). A historical database has been implemented with monitoring data for the period 2000-2006 (data on rivers, bathing and marine coastal waters and on the characterization of Wastewater Treatment Plant (WWTP) discharges) from the institutional activity of Veneto Regional Environmental Prevention and Protection Agency (ARPAV). An integrated areal analysis for the microbiological investigation of homogeneous stretches along the coast of the Province of Venice was performed for a preliminary characterization of the bathing water profile considering water quality status and existing pressure sources. ARPAV is the institutional body responsible for environmental monitoring and control activities. Data were produced from monitoring and controls made available by the Regional Environmental Informative System and extracted and elaborated for the period of interest (2000-2006). Sampling and analysis of microbiological parameters were executed following the official Italian methods in accordance with international procedures (APHA et al. 1998). For the purpose of this study, the coast was divided into eight stretches, which were considered to be homogeneous according to their physical and geographical characteristics. An ANOVA statistical assessment has been performed on stretches I, V and VIII. From the integrated areal analysis of microbiological parameters in the homogeneous stretches along the coast of all the investigated matrices, high mean levels of faecal contamination were found in some cases. The most critical situation amongst the stretches evaluated is to be found in stretch VIII-Ca' Roman, Sottomarina and Isola Verde shores (Southern part of the Province). These results can be widely attributed to pressure sources from the Brenta and Adige rivers, rather than to local contributions. Stretches VI and VII, which correspond to the area from Punta Sabbioni (Cavallino shore N-E) to the Pellestrina shore (S-W), present the best conditions for faecal contamination parameters (low pollution levels). These situations can probably be explained given that WWTPs 7 and 8 have two submarine outfalls at a distance of about 4 km from the coastline and therefore a discharge point which is distant from the bathing and marine coastal monitoring stations; there are also no river mouths in these two stretches. Due to lack of data, it was not possible to implement seasonal assessments. This study aimed to develop an integrated areal analysis for biological parameters along the coast over the period 2000-2006 for the identified homogeneous stretches in order to develop a preliminary approach for the characterization of the water profile, as requested by directive 2006/7/EC. From the integrated analysis of the stretches, it is evident that in some cases there are high levels of faecal contamination along the coast which can be caused by river flows which heavily condition the quality of coastal waters as verified with the statistical assessment. From the preliminary analysis, the submarine outfalls seem to be the best solution to guarantee good bathing water quality on the coast. Nevertheless, it must be observed that this solution cannot overlook the possible impact of the discharges on seawaters intended for a specific use, such as mussel farms with reference to coastal hydrodynamics. Therefore, a sound wastewater dispersion analysis on the discharges of the WWTPs for the identification of the interested area and the level of contamination must be performed; a modelling study on pollution dispersion is complementary to this study (Scroccaro et al. 2009). This analysis highlights the critical stretches as being numbers II and, above all, VIII with particular correlation with the main river mouths. Thus, it is evident that the issue of microbiological impact must be studied following a river basin approach according to the influence of river loads on coastal areas.
Quantitative method for measuring heat flux emitted from a cryogenic object
Duncan, Robert V.
1993-01-01
The present invention is a quantitative method for measuring the total heat flux, and of deriving the total power dissipation, of a heat-fluxing object which includes the steps of placing an electrical noise-emitting heat-fluxing object in a liquid helium bath and measuring the superfluid transition temperature of the bath. The temperature of the liquid helium bath is thereafter reduced until some measurable parameter, such as the electrical noise, exhibited by the heat-fluxing object or a temperature-dependent resistive thin film in intimate contact with the heat-fluxing object, becomes greatly reduced. The temperature of the liquid helum bath is measured at this point. The difference between the superfluid transition temperature of the liquid helium bath surrounding the heat-fluxing object, and the temperature of the liquid helium bath when the electrical noise emitted by the heat-fluxing object becomes greatly reduced, is determined. The total heat flux from the heat-fluxing object is determined as a function of this difference between these temperatures. In certain applications, the technique can be used to optimize thermal design parameters of cryogenic electronics, for example, Josephson junction and infra-red sensing devices.
Quantitative method for measuring heat flux emitted from a cryogenic object
Duncan, R.V.
1993-03-16
The present invention is a quantitative method for measuring the total heat flux, and of deriving the total power dissipation, of a heat-fluxing object which includes the steps of placing an electrical noise-emitting heat-fluxing object in a liquid helium bath and measuring the superfluid transition temperature of the bath. The temperature of the liquid helium bath is thereafter reduced until some measurable parameter, such as the electrical noise, exhibited by the heat-fluxing object or a temperature-dependent resistive thin film in intimate contact with the heat-fluxing object, becomes greatly reduced. The temperature of the liquid helum bath is measured at this point. The difference between the superfluid transition temperature of the liquid helium bath surrounding the heat-fluxing object, and the temperature of the liquid helium bath when the electrical noise emitted by the heat-fluxing object becomes greatly reduced, is determined. The total heat flux from the heat-fluxing object is determined as a function of this difference between these temperatures. In certain applications, the technique can be used to optimize thermal design parameters of cryogenic electronics, for example, Josephson junction and infrared sensing devices.
Wong, Su-ming; Ng, Ting Guan; Baba, Roshidah
2013-11-01
Staphylococcus aureus is frequently found in patients with atopic dermatitis (AD) and contributes to disease exacerbation. The objective of this study was to evaluate the efficacy and safety of bleach baths as an adjunctive treatment in AD patients. Patients between 2 and 30 years old with moderate to severe AD were enrolled in a prospective, randomized, placebo-controlled study. Patients soaked in diluted bleach or distilled water baths for 10 min, twice a week for 2 months. Efficacy assessments included the Eczema Area and Severity Index (EASI) scores and S. aureus density was determined using quantitative bacterial cultures. Patients in the treatment group showed significant reductions in EASI scores. A 41.9% reduction in S. aureus density from baseline was seen at 1 month further reducing to 53.3% at 2 months. Equal numbers of patients in both groups experienced mild side-effects. This study demonstrates that diluted bleach baths clinically improved AD in as little as 1 month. No patient withdrew from the treatment arm because of intolerance to the baths. © 2013 Japanese Dermatological Association.
Application of thermodynamics and Wagner model on two problems in continuous hot-dip galvanizing
NASA Astrophysics Data System (ADS)
Liu, Huachu; He, Yanlin; Li, Lin
2009-12-01
Firstly in this paper, the influence of H 2 and water vapor content on selective oxidation occurred in continuous hot-dip galvanizing has been studied by thermodynamics and Wagner model, then, the Gibbs energy of each possible aluminothermic reducing reaction in zinc bath was calculated in order to judge the possibility of these reactions. It was found that oxides' amounts and oxidation type were greatly related to the H 2 and water content in the annealing atmosphere. And from the view of thermodynamics, surface oxides (MnO, Cr 2O 3, SiO 2 etc.) can be reduced by the effective Al in Zn bath.
Xu, Li; Wu, Lin; Liu, Tingting; Xing, Wenrong; Cao, Xinsheng; Zhang, Shu; Su, Zongyi
2017-09-01
[Purpose] The aim of our study was to explore the changes in the blood of servicemen in sub-health conditions during a 21-day balneotherapy program. [Subjects and Methods] For this study, 129 servicemen in sub-health condition were recruited. The subjects were randomly divided into either the balneotherapy group (70) or the control group (59). Subjects in the balneotherapy group received whole-body immersion bath therapy in thermomineral water (30 min daily) for 21 days. Their blood samples were examined 1 day before and after balneotherapy. The parameters studied included mean corpuscular hemoglobin (MCH), mean corpuscular hemoglobin concentration (MCHC), white blood cell (WBC), lactic acid (LAC), alanine aminotransferase (ALT), glucose (GLU), and triglycerides (TG) levels. [Results] After 21 days of balneotherapy, MCH levels and MCHC increased significantly and WBC counts increased significantly. LAC levels decreased significantly. ALT, GLU, and TG levels decreased significantly. In the control group, there were no statistical differences before and after tap water baths following the same procedure. [Conclusion] A 21-day balneotherapy program significantly improved blood cell counts and blood biochemical indexes and reduced ponogen levels in servicemen in sub-health condition.
Benedé, Juan L; Chisvert, Alberto; Giokas, Dimosthenis L; Salvador, Amparo
2016-01-15
In this work, a new approach that combines the advantages of stir bar sorptive extraction (SBSE) and dispersive solid phase extraction (DSPE), i.e. stir bar sorptive-dispersive microextraction (SBSDµE), is employed as enrichment and clean-up technique for the sensitive determination of eight lipophilic UV filters in water samples. The extraction is accomplished using a neodymium stir bar magnetically coated with oleic acid-coated cobalt ferrite magnetic nanoparticles (MNPs) as sorbent material, which are detached and dispersed into the solution at high stirring rate. When stirring is stopped, MNPs are magnetically retrieved onto the stir bar, which is subjected to thermal desorption (TD) to release the analytes into the gas chromatography-mass spectrometry (GC-MS) system. The SBSDµE approach allows for lower extraction time than SBSE and easier post-extraction treatment than DSPE, while TD allows for an effective and solvent-free injection of the entire quantity of desorbed analytes into GC-MS, and thus achieving a high sensitivity. The main parameters involved in TD, as well as the extraction time, were evaluated. Under the optimized conditions, the method was successfully validated showing good linearity, limits of detection and quantification in the low ngL(-1) range and good intra- and inter-day repeatability (RSD<12%). This accurate and sensitive analytical method was applied to the determination of trace amounts of UV filters in three bathing water samples (river, sea and swimming pool) with satisfactory relative recovery values (80-116%). Copyright © 2015 Elsevier B.V. All rights reserved.
Installation Assessment of Frankford Arsenal.
1977-10-01
sulfate , sulfuric acid , ac ’solution 40 Hot water bath 41 Nickel plate Nickel sulfate and chloride sulfuric acid , acid ...solution 42 Chromium Copper plate Copper sulfate and sulfuric acid , acid solution 11-14 TABLE 11-2 (continued) Tank No. Plating Process Use Contents...46 Water rinse Water 47 Water rinse Water 48 Water rinse Water 49 Acid Chromic acid , acetic acid , nickel sulfate and sulfuric
PERFORMANCE OF RETENTION PONDS AND CONSTRUCTED WETLANDS FOR ATTENUATING BACTERIAL STRESSORS
Microbial contamination from fecal origins in stormwater runoff poses a risk to human health through the consumption of drinking water and recreational and bathing contact with surface waters. Indicator bacteria serve as the regulatory meter by which water quality is measured and...
Current Environmental Protection Agency (EPA) recommended microbiological monitoring practices for bathing beach water quality were suggested in 1968, as a part of the fecal coliform guideline developed by the Federal Water Pollution Control Administration. The guideline stated ...
Bath for electrolytic reduction of alumina and method therefor
Brown, Craig W.; Brooks, Richard J.; Frizzle, Patrick B.; Juric, Drago D.
2001-07-10
An electrolytic bath for use during the electrolytic reduction of alumina to aluminum. The bath comprises a molten electrolyte having the following ingredients: (a) AlF.sub.3 and at least one salt selected from the group consisting of NaF, KF, and LiF; and (b) about 0.004 wt. % to about 0.2 wt. %, based on total weight of the molten electrolyte, of at least one transition metal or at least one compound of the metal or both. The compound may be, for example, a fluoride, oxide, or carbonate. The metal can be nickel, iron, copper, cobalt, or molybdenum. The bath can be employed in a combination that includes a vessel for containing the bath and at least one non-consumable anode and at least one dimensionally stable cathode in the bath. Employing the bath of the present invention during electrolytic reduction of alumina to aluminum can improve the wetting of aluminum on a cathode by reducing or eliminating the formation of non-metallic deposits on the cathode.
Bushon, R.N.; Brady, A.M.; Likirdopulos, C.A.; Cireddu, J.V.
2009-01-01
Aims: The aim of this study was to examine a rapid method for detecting Escherichia coli and enterococci in recreational water. Methods and Results: Water samples were assayed for E. coli and enterococci by traditional and immunomagnetic separation/adenosine triphosphate (IMS/ATP) methods. Three sample treatments were evaluated for the IMS/ATP method: double filtration, single filtration, and direct analysis. Pearson's correlation analysis showed strong, significant, linear relations between IMS/ATP and traditional methods for all sample treatments; strongest linear correlations were with the direct analysis (r = 0.62 and 0.77 for E. coli and enterococci, respectively). Additionally, simple linear regression was used to estimate bacteria concentrations as a function of IMS/ATP results. The correct classification of water-quality criteria was 67% for E. coli and 80% for enterococci. Conclusions: The IMS/ATP method is a viable alternative to traditional methods for faecal-indicator bacteria. Significance and Impact of the Study: The IMS/ATP method addresses critical public health needs for the rapid detection of faecal-indicator contamination and has potential for satisfying US legislative mandates requiring methods to detect bathing water contamination in 2 h or less. Moreover, IMS/ATP equipment is considerably less costly and more portable than that for molecular methods, making the method suitable for field applications. ?? 2009 The Authors.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hsiang, J.-T., E-mail: cosmology@gmail.com; Department of Physics, National Dong Hwa University, Hualien 97401, Taiwan; Hu, B.L.
2015-11-15
The existence and uniqueness of a steady state for nonequilibrium systems (NESS) is a fundamental subject and a main theme of research in statistical mechanics for decades. For Gaussian systems, such as a chain of classical harmonic oscillators connected at each end to a heat bath, and for classical anharmonic oscillators under specified conditions, definitive answers exist in the form of proven theorems. Answering this question for quantum many-body systems poses a challenge for the present. In this work we address this issue by deriving the stochastic equations for the reduced system with self-consistent backaction from the two baths, calculatingmore » the energy flow from one bath to the chain to the other bath, and exhibiting a power balance relation in the total (chain + baths) system which testifies to the existence of a NESS in this system at late times. Its insensitivity to the initial conditions of the chain corroborates to its uniqueness. The functional method we adopt here entails the use of the influence functional, the coarse-grained and stochastic effective actions, from which one can derive the stochastic equations and calculate the average values of physical variables in open quantum systems. This involves both taking the expectation values of quantum operators of the system and the distributional averages of stochastic variables stemming from the coarse-grained environment. This method though formal in appearance is compact and complete. It can also easily accommodate perturbative techniques and diagrammatic methods from field theory. Taken all together it provides a solid platform for carrying out systematic investigations into the nonequilibrium dynamics of open quantum systems and quantum thermodynamics. -- Highlights: •Nonequilibrium steady state (NESS) for interacting quantum many-body systems. •Derivation of stochastic equations for quantum oscillator chain with two heat baths. •Explicit calculation of the energy flow from one bath to the chain to the other bath. •Power balance relation shows the existence of NESS insensitive to initial conditions. •Functional method as a viable platform for issues in quantum thermodynamics.« less
NASA Astrophysics Data System (ADS)
Iiyama, Junichi; Matsushita, Kensuke; Tanaka, Nobuyuki; Kawahira, Kazumi
2008-07-01
We have previously reported that thermal vasodilation following warm-water bathing and low-temperature sauna bathing (LTSB) at 60 °C for 15 min improves the cardiac function in patients with congestive heart failure. Through a comparative before-and-after study, we studied the hemodynamic and clinical effects of single exposure to LTSB in cerebral palsy (CP) patients who usually suffer from chilled extremities and low cardiac output. The study population comprised 16 patients ranging between 19 and 53 years with severe motor and intellectual disabilities. Noninvasive methods were used to estimate the systemic and peripheral circulatory changes before and after LTSB. Using blood flow velocity analysis, the pulsatile and resistive indexes of the peripheral arteries of the patients’ lower limbs were calculated. Following LTSB, the patients’ deep body temperature increased significantly by 1°C. Their heart rates increased and blood pressure decreased slightly. The total peripheral resistance decreased by 11%, and the cardiac output increased by 14%. There was significant improvement in the parameters that are indicative of the peripheral circulatory status, including the skin blood flow, blood flow velocity, pulsatile index, and resistive index. Numbness and chronic myalgia of the extremities decreased. There were no adverse side effects. Thus, it can be concluded that LTSB improves the peripheral circulation in CP patients.
Iiyama, Junichi; Matsushita, Kensuke; Tanaka, Nobuyuki; Kawahira, Kazumi
2008-07-01
We have previously reported that thermal vasodilation following warm-water bathing and low-temperature sauna bathing (LTSB) at 60 degrees C for 15 min improves the cardiac function in patients with congestive heart failure. Through a comparative before-and-after study, we studied the hemodynamic and clinical effects of single exposure to LTSB in cerebral palsy (CP) patients who usually suffer from chilled extremities and low cardiac output. The study population comprised 16 patients ranging between 19 and 53 years with severe motor and intellectual disabilities. Noninvasive methods were used to estimate the systemic and peripheral circulatory changes before and after LTSB. Using blood flow velocity analysis, the pulsatile and resistive indexes of the peripheral arteries of the patients' lower limbs were calculated. Following LTSB, the patients' deep body temperature increased significantly by 1 degrees C. Their heart rates increased and blood pressure decreased slightly. The total peripheral resistance decreased by 11%, and the cardiac output increased by 14%. There was significant improvement in the parameters that are indicative of the peripheral circulatory status, including the skin blood flow, blood flow velocity, pulsatile index, and resistive index. Numbness and chronic myalgia of the extremities decreased. There were no adverse side effects. Thus, it can be concluded that LTSB improves the peripheral circulation in CP patients.
Method of making foam-encapsulated laser targets
Rinde, James A.; Fulton, Fred J.
1977-01-01
Foam-encapsulated laser fusion targets are fabricated by suspending fusion fuel filled shells in a solution of cellulose acetate, extruding the suspension through a small orifice into a bath of ice water, soaking the thus formed shell containing cellulose acetate gel in the water to extract impurities, freezing the gel, and thereafter freeze-drying wherein water and solvents sublime and the gel structure solidifies into a low-density microcellular foam containing one or more encapsulated fuel-filled shells. The thus formed material is thereafter cut and mounted on a support to provide laser fusion targets containing a fuel-filled shell surrounded by foam having a thickness of 10 to 60 .mu.m, a cell size of less than 2 .mu.m, and density of 0.08 to 0.6.times.10.sup.3 kg/m.sup.3. Various configured foam-encapsulated targets capable of being made by the encapsulation method are illustrated.
Santos, M V; Zaritzky, N; Califano, A
2008-07-01
The presence of Escherichia coli is linked with sanitary deficiencies and undercooking of meat products. Recent studies have detected E. coli O157:H7 in black blood sausages. Minimum time-temperature specifications to kill the bacteria were obtained by numerical simulations of the microscopic heat conduction equation using the finite element method, and calculating the temperature profile of the sausage and the population of E. coli at the coldest point during heating. The model was validated by heating sausages in a water-bath. The effects of heat transfer coefficients and water temperatures on the required time to achieve an inactivation value (IV) of 12(log) are reported. Macroscopic heat balances were simultaneously solved to consider the temperature drop in the water batch as a function of the ratio between the mass of thermally treated sausage and the heat capacity of the system.
Evaluation of ultrasonic cavitation of metallic and non-metallic surfaces
NASA Technical Reports Server (NTRS)
Mehta, Narinder K.
1992-01-01
1,1,2 trichloro-1,2,2 trifluoro ethane (CFC-113) commercially known as Freon-113 is the primary test solvent used for validating the cleaned hardware at the Kennedy Space Center (KSC). Due to the ozone depletion problem, the current United States policy calls for the phase out of Freons by 1995. NASAs chlorofluorocarbon (CFC) replacement group at KSC has opted to use water as a replacement fluid for the validation process since water is non-toxic, inexpensive, and is environmentally friendly. The replacement validation method calls for the ultrasonification of the small parts with water at 52 C for a cycle or two of 10 min duration wash using commercial ultrasonic baths. In this project, experimental data was obtained to assess the applicability of the proposed validation method for any damage of the metallic and non-metallic surfaces resulting from ultrasonic cavitation.
Liao, Wen-Chun; Wang, Lee; Kuo, Ching-Pyng; Lo, Chyi; Chiu, Ming-Jang; Ting, Hua
2013-12-01
The decrease in core body temperature before sleep onset and during sleep is associated with dilation of peripheral blood vessels, which permits heat dissipation from the body core to the periphery. A lower core temperature coupled with a higher distal (hands and feet) temperature before sleep are associated with shorter sleep latency and better sleep quality. A warm footbath is thought to facilitate heat dissipation to improve sleep outcomes. This study examined the effect of a warm footbath (40°C water temperature, 20-min duration) on body temperature and sleep in older adults (≥55 years) with good and poor sleep. Two groups and an experimental crossover design was used. Forty-three adults responded to our flyer and 25 participants aged 59.8±3.7 years (poor sleeper with a Pittsburgh Sleep Quality Index score≥5=17; good sleepers with a Pittsburgh Sleep Quality Index score<5=8) completed this study. All participants had body temperatures (core, abdomen, and foot) and polysomnography recorded for 3 consecutive nights. The first night was for adaptation and sleep apnea screening. Participants were then randomly assigned to either the structured foot bathing first (second night) and non-bathing second (third night) condition or the non-bathing first (second night) and foot bathing second (third night) condition. A footbath before sleep significantly increased and retained foot temperatures in both good and poor sleepers. The pattern of core temperatures during foot bathing was gradually elevated (poor sleepers vs. good sleepers=+0.40±0.58°C vs. +0.66±0.17°C). There were no significant changes in polysomnographic sleep and perceived sleep quality between non-bathing and bathing nights for both groups. A footbath of 40°C water temperature and 20-min duration before sleep onset increases foot temperatures and distal-proximal skin temperature gradients to facilitate vessel dilatation and elevates core temperature to provide heat load to the body. This footbath does not alter sleep in older adults with good and poor sleep. Copyright © 2013 Elsevier Ltd. All rights reserved.
Thermal baths as quantum resources: more friends than foes?
NASA Astrophysics Data System (ADS)
Kurizki, Gershon; Shahmoon, Ephraim; Zwick, Analia
2015-12-01
In this article we argue that thermal reservoirs (baths) are potentially useful resources in processes involving atoms interacting with quantized electromagnetic fields and their applications to quantum technologies. One may try to suppress the bath effects by means of dynamical control, but such control does not always yield the desired results. We wish instead to take advantage of bath effects, that do not obliterate ‘quantumness’ in the system-bath compound. To this end, three possible approaches have been pursued by us. (i) Control of a quantum system faster than the correlation time of the bath to which it couples: such control allows us to reveal quasi-reversible/coherent dynamical phenomena of quantum open systems, manifest by the quantum Zeno or anti-Zeno effects (QZE or AZE, respectively). Dynamical control methods based on the QZE are aimed not only at protecting the quantumness of the system, but also diagnosing the bath spectra or transferring quantum information via noisy media. By contrast, AZE-based control is useful for fast cooling of thermalized quantum systems. (ii) Engineering the coupling of quantum systems to selected bath modes: this approach, based on field-atom coupling control in cavities, waveguides and photonic band structures, allows one to drastically enhance the strength and range of atom-atom coupling through the mediation of the selected bath modes. More dramatically, it allows us to achieve bath-induced entanglement that may appear paradoxical if one takes the conventional view that coupling to baths destroys quantumness. (iii) Engineering baths with appropriate non-flat spectra: this approach is a prerequisite for the construction of the simplest and most efficient quantum heat machines (engines and refrigerators). We may thus conclude that often thermal baths are ‘more friends than foes’ in quantum technologies.
Barnes, Rebecca K; Jepson, Marcus; Thomas, Clare; Jackson, Sue; Metcalfe, Chris; Kessler, David; Cramer, Helen
2018-06-01
The study aim was to assess implementation fidelity (i.e., adherence) to a talk-based primary care intervention using Conversation Analytic (CA) methods. The context was a UK feasibility trial where General Practitioners (GPs) were trained to use "BATHE" (Background,Affect,Trouble,Handling,Empathy) - a technique to screen for psychosocial issues during consultations - with frequently attending patients. 35 GPs received BATHE training between July-October 2015. 15 GPs across six practices self-selected to record a sample of their consultations with study patients at three and six months. 31 consultations were recorded. 21/26 patients in four intervention practices gave permission for analysis. The recordings were transcribed and initially coded for the presence or absence of the five BATHE components. CA methods were applied to assess delivery, focusing on position and composition of each component, and patients' responses. Initial coding showed most of the BATHE components to be present in most contacts. However the CA analysis revealed unplanned deviations in position and adaptations in composition. Frequently the intervention was initiated too early in the consultation, and the BATHE questions misunderstood by patients as pertaining to their presenting problems rather than the psychosocial context for their problems. Often these deviations resulted in reducing theoretical fidelity of the intervention as a whole. A CA approach enabled a dynamic assessment of the delivery and receipt of BATHE in situ revealing common pitfalls in delivery and provided valuable examples of more and less efficacious implementations. During the trial this evidence was used in top-up trainings to address problems in delivery and to improve GP engagement. Using CA methods enabled a more accurate assessment of implementation fidelity, a fuller description of the intervention itself, and enhanced resources for future training. When positioned appropriately, BATHE can be a useful tool for eliciting information about the wider context of the medical visit. Copyright © 2018 Elsevier Ltd. All rights reserved.
Thermal balneotherapy induces changes of the platelet serotonin transporter in healthy subjects.
Marazziti, Donatella; Baroni, Stefano; Giannaccini, Gino; Catena Dell'Osso, Mario; Consoli, Giorgio; Picchetti, Michela; Carlini, Marina; Massimetti, Gabriele; Provenzano, Serafina; Galassi, Antonio
2007-10-01
Although the beneficial effects of balneotherapy have been recognized since a long time, a few information is available on the biological mechanisms underlying them and the subjective feelings of increased well-being and mood. The links between the serotonin (5-HT) system and mood prompted us to investigate the 5-HT platelet transporter (SERT), which is considered a reliable, peripheral marker of the same structure present in presynaptic neurons, in 20 healthy volunteers before (t0) and 30 min after (t1) thermal balneotherapy with ozonized water of Montecatini spa, as compared with a similar group who underwent a bath in non-mineral water. The SERT was evaluated by means of the specific binding of (3)H-paroxetine ((3)H-Par) to platelet membranes. Equilibrium-saturation binding data, the maximal binding capacity (Bmax) and the dissociation constant (Kd), were obtained by means of the Scatchard analysis. The results showed that, while Bmax values did not change in both groups, the Kd values decreased significantly at t1 only in those subjects who bathed in ozonized water. The results of this study, while showing a decrease of the dissociation constant (Kd) which is the inverse of affinity constant, of (3)H-Par binding to SERT in all subjects after balneotherapy and not in those bathing in normal water, suggest that SERT modifications may be related to a specific effect of ozonized water and, perhaps, also to the increased sense of well-being.
PRETREATING THORIUM FOR ELECTROPLATING
Beach, J.G.; Schaer, G.R.
1959-07-28
A method is presented for pretreating a thorium surface prior to electroplating the surface. The pretreatment steps of the invention comprise cleaning by vapor blasting the surface, anodically pickling in a 5 to 15% by volume aqueous hydrochloric acid bath with a current of 125 to 250 amp/sq ft for 3 to 5 min at room temperature, chemically pickling the surface in a 5 to 15% by volume of aqueous sulfuric acid for 3 to 5 min at room temperature, and rinsing the surface with water.
1989-01-01
25 wt % Solid Sorbent Collection solution in water 1. Glass tubing (6.0 mm OD, (Aldrich G400-y or equivalent) 4.0 mm ID) 2. 2,4- Dinitrophenylhydrazine ... dinitrophenylhydrazine in boiling 4M HCI. When the DNPH has dissolved completely, cool the Folution in an ice bath. Collect the yellow crystalline precipitate... dinitrophenylhydrazine . Add the aldehyde in excess to assure that no underivatized DNPH remains. Extract the derivative with dichloromethane. Remove the
ANALYTICAL METHOD FOR THE ABSORPTIOMETRIC DETERMINATION OF BORON IN AMMONIA SOLUTION
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
1962-01-01
ABS>A weighed sample is evaporated to dryness with caustic soda solution on a water bath. The residue is dissolved by addlng a solution of curcumin in acetic acid. After adding a mixture of H/sub 2/SO/sub 4/ and acetic acid, the solution is allowed to stand at room temperature for 15 minutes. The solution is then diluted to 100 ml with ethanol, and a portion is filtered and measured absorptiometrically on the residue as the curcumin complex. (P.C.H.)
Quantitative nuclear magnetic resonance for additives determination in an electrolytic nickel bath.
Ostra, Miren; Ubide, Carlos; Vidal, Maider
2011-02-01
The use of proton nuclear magnetic resonance (¹H-NMR) for the quantitation of additives in a commercial electrolytic nickel bath (Supreme Plus Brilliant, Atotech formulation) is reported. A simple and quick method is described that needs only the separation of nickel ions by precipitation with NaOH. The four additives in the bath (A-5(2X), leveler; Supreme Plus Brightener (SPB); SA-1, leveler; NPA, wetting agent; all of them are commercial names from Atotech) can be quantified, whereas no other analytical methods have been found in the literature for SA-1 and NPA. Two calibration methods have been tried: integration of NMR signals with the use of a proper internal standard and partial least squares regression applied to the characteristic NMR peaks. The multivariate method was preferred because of accuracy and precision. Multivariate limits of detection of about 4 mL L⁻¹ A-5(2X), 0.4 mL L⁻¹ SPB, 0.2 mL L⁻¹ SA-1 and 0.6 mL L⁻¹ NPA were found. The dynamic ranges are suitable to follow the concentration of additives in the bath along electrodeposition. ¹H-NMR spectra provide evidence for SPB and SA-1 consumption (A-5(2X) and NPA keep unchanged along the process) and the growth of some products from SA-1 degradation can be followed. The method can, probably, be extended to other electrolytic nickel baths.
Hypothermic manipulation of bone cement can extend the handling time during vertebroplasty
2012-01-01
Background Polymethylmethacrylate (PMMA) is commonly used for clinical applications. However, the short handling time increases the probability of a surgeon missing the crucial period in which the cement maintains its ideal viscosity for a successful injection. The aim of this article was to illustrate the effects a reduction in temperature would have on the cement handling time during percutaneous vertebroplasty. Methods The injectability of bone cement was assessed using a cement compressor. By twisting the compressor, the piston transmits its axial load to the plunger, which then pumps the bone cement out. The experiments were categorized based on the different types of hypothermic manipulation that were used. In group I (room temperature, sham group), the syringes were kept at 22°C after mixing the bone cement. In group 2 (precooling the bone cement and the container), the PMMA powder and liquid, as well as the beaker, spatula, and syringe, were stored in the refrigerator (4°C) overnight before mixing. In group 3 (ice bath cooling), the syringes were immediately submerged in ice water after mixing the bone cement at room temperature. Results The average liquid time, paste time, and handling time were 5.1 ± 0.7, 3.4 ± 0.3, and 8.5 ± 0.8 min, respectively, for group 1; 9.4 ± 1.1, 5.8 ± 0.5, and 15.2 ± 1.2 min, respectively, for group 2; and 83.8 ± 5.2, 28.8 ± 6.9, and 112.5 ± 11.3 min, respectively, for group 3. The liquid and paste times could be increased through different cooling methods. In addition, the liquid time (i.e. waiting time) for ice bath cooling was longer than for that of the precooling method (p < 0.05). Conclusions Both precooling (i.e. lowering the initial temperature) and ice bath cooling (i.e. lowering the surrounding temperature) can effectively slow polymerization. Precooling is easy for clinical applications, while ice bath cooling might be more suitable for multiple-level vertebroplasty. Clinicians can take advantage of the improved injectability without any increased cost. PMID:23072273
Kulkarni, Vrushali M; Rathod, Virendra K
2014-03-01
The present work deals with the mapping of an ultrasonic bath for the maximum extraction of mangiferin from Mangifera indica leaves. I3(-) liberation experiments (chemical transformations) and extraction (physical transformations) were carried out at different locations in an ultrasonic bath and compared. The experimental findings indicated a similar trend in variation in an ultrasonic bath by both these methods. Various parameters such as position and depth of vessel in an ultrasonic bath, diameter and shape of a vessel, frequency and input power which affect the extraction yield have been studied in detail. Maximum yield of mangiferin obtained was approximately 31 mg/g at optimized parameters: distance of 2.54 cm above the bottom of the bath, 7 cm diameter of vessel, flat bottom vessel, 6.35 cm liquid height, 122 W input power and 25 kHz frequency. The present work indicates that the position and depth of vessel in an ultrasonic bath, diameter and shape of a vessel, frequency and input power have significant effect on the extraction yield. This work can be used as a base for all ultrasonic baths to obtain maximum efficiency for ultrasound assisted extraction. Copyright © 2013 Elsevier B.V. All rights reserved.
Bath for electrolytic reduction of alumina and method therefor
Brown, Craig W.; Brooks, Richard J.; Frizzle, Patrick B.; Juric, Drago D.
2002-11-26
An electrolytic bath for use during the electrolytic reduction of alumina to aluminum. The bath comprises a molten electrolyte having the following ingredients: (a) AlF.sub.3 and at least one salt selected from the group consisting of NaF, KF, and LiF; and (b) about 0.004 wt. % to about 0.2 wt. %, based on total weight of the molten electrolyte, of at least one transition metal or at least one compound of the metal or both. The compound may be, for example, a fluoride, oxide, or carbonate. The metal can be nickel, iron, copper, cobalt, or molybdenum. The bath can be employed in a combination that includes a vessel for containing the bath and at least one non-consumable anode and at least one dimensionally stable cathode in the bath. Employing the bath of the present invention during electrolytic reduction of alumina to aluminum can improve the wetting of aluminum on a cathode by reducing or eliminating the formation of non-metallic deposits on the cathode. Removing sulfur from the bath can also minimize cathode deposits. Aluminum formed on the cathode can be removed directly from the cathode.
Valente, Marta Sofia; Pedro, Paulo; Alonso, M Carmen; Borrego, Juan J; Dionísio, Lídia
2010-03-01
Monitoring the microbiological quality of water used for recreational activities is very important to human public health. Although the sanitary quality of recreational marine waters could be evaluated by standard methods, they are time-consuming and need confirmation. For these reasons, faster and more sensitive methods, such as the defined substrate-based technology, have been developed. In the present work, we have compared the standard method of membrane filtration using Tergitol-TTC agar for total coliforms and Escherichia coli, and Slanetz and Bartley agar for enterococci, and the IDEXX defined substrate technology for these faecal pollution indicators to determine the microbiological quality of natural recreational waters. ISO 17994:2004 standard was used to compare these methods. The IDEXX for total coliforms and E. coli, Colilert, showed higher values than those obtained by the standard method. Enterolert test, for the enumeration of enterococci, showed lower values when compared with the standard method. It may be concluded that more studies to evaluate the precision and accuracy of the rapid tests are required in order to apply them for routine monitoring of marine and freshwater recreational bathing areas. The main advantages of these methods are that they are more specific, feasible and simpler than the standard methodology.
"EPA'S NATIONAL BEACHES STUDY: HUNTINGTON BEACH, 2003"
The original U. S. Environmental Protection Agency (EPA) recreational water health studies, initiated in 1972 and completed in 1982, were designed to determine the relationship between swimming-associated gastroenteritis and the quality of the bathing water. However, these healt...
Microorganism Removal in Permeable Pavement Parking Lots ...
Three types of permeable pavements (pervious concrete, permeable interlocking concrete pavers, and porous asphalt) were monitored at the Edison Environmental Center in Edison, New Jersey for indicator organisms such as fecal coliform, enterococci, and E. coli. Results showed that porous asphalt had much lower concentration in monitored infiltrate compared to pervious concrete and permeable interlocking concrete pavers. Concentrations of monitored organisms in infiltrate from porous asphalt were consistently below the bathing water quality standard. Fecal coliform and enterococci exceeded bathing water quality standards more than 72% and 34% of the time for permeable interlocking concrete pavers and pervious concrete, respectively. Purpose is to evaluate the performance of permeable pavement in removing indicator organisms from infiltrating stormwater runoff.
Temperature uniformity in hyperthermal tumor therapy
NASA Technical Reports Server (NTRS)
Harrison, G. H.; Robinson, J. E.; Samaras, G. M.
1978-01-01
Mouse mammary tumors heated by water bath or by microwave-induced hyperthermia exhibit a response that varies sharply with treatment temperature; therefore, uniform heating of the tumor is essential to quantitate the biological response as a function of temperature. C3H tumors implanted on the mouse flank were easily heated to uniformities within 0.1 C by using water baths. Cold spots up to 1 C below the desired treatment temperature were observed in the same tumors implanted on the hind leg. These cold spots were attributed to cooling by major blood vessels near the tumor. In this case temperature uniformity was achieved by the deposition of 2450 MHz microwave energy into the tumor volume by using parallel-opposed applicators.
Björklund, Karin; Bondelind, Mia; Karlsson, Anna; Karlsson, Dick; Sokolova, Ekaterina
2018-02-01
The risk from chemical substances in surface waters is often increased during wet weather, due to surface runoff, combined sewer overflows (CSOs) and erosion of contaminated land. There are strong incentives to improve the quality of surface waters affected by human activities, not only from ecotoxicity and ecosystem health perspectives, but also for drinking water and recreational purposes. The aim of this study is to investigate the influence of urban stormwater discharges and CSOs on receiving water in the context of chemical health risks and recreational water quality. Transport of copper (Cu) and benzo[a]pyrene (BaP) in the Göta River (Sweden) was simulated using a hydrodynamic model. Within the 16 km modelled section, 35 CSO and 16 urban stormwater point discharges, as well as the effluent from a major wastewater treatment plant, were included. Pollutant concentrations in the river were simulated for two rain events and investigated at 13 suggested bathing sites. The simulations indicate that water quality guideline values for Cu are exceeded at several sites, and that stormwater discharges generally give rise to higher Cu and BaP concentrations than CSOs. Due to the location of point discharges and the river current inhibiting lateral mixing, the north shore of the river is better suited for bathing. Peak concentrations have a short duration; increased concentrations of the pollutants may however be present for several days after a rain event. Monitoring of river water quality indicates that simulated Cu and BaP concentrations are in the same order of magnitude as measured concentrations. It is concluded that hydrodynamic modelling is a useful tool for identifying suitable bathing sites in urban surface waters and areas of concern where mitigation measures should be implemented to improve water quality. Copyright © 2017 Elsevier Ltd. All rights reserved.
Song, Gang; Wang, Xinming; Chen, Diyun; Chen, Yongheng
2011-04-01
This study investigates the contribution of radon ((222)Rn)-bearing water to indoor (222)Rn in thermal baths. The (222)Rn concentrations in air were monitored in the bathroom and the bedroom. Particulate matter (PM, both PM(10) and PM(2.5)) and carbon dioxide (CO(2)) were also monitored with portable analyzers. The bathrooms were supplied with hot spring water containing 66-260 kBq m(-3) of (222)Rn. The results show that the spray of hot spring water from the bath spouts is the dominant mechanism by which (222)Rn is released into the air of the bathroom, and then it diffuses into the bedroom. Average (222)Rn level was 110-410% higher in the bedrooms and 510-1200% higher in the bathrooms compared to the corresponding average levels when there was no use of hot spring water. The indoor (222)Rn levels were influenced by the (222)Rn concentrations in the hot spring water and the bathing times. The average (222)Rn transfer coefficients from water to air were 6.2 × 10(-4)-4.1 × 10(-3). The 24-h average levels of CO(2) and PM(10) in the hotel rooms were 89% and 22% higher than the present Indoor Air Quality (IAQ) standard of China. The main particle pollutant in the hotel rooms was PM(2.5). Radon and PM(10) levels in some hotel rooms were at much higher concentrations than guideline levels, and thus the potential health risks to tourists and especially to the hotel workers should be of great concern, and measures should be taken to lower inhalation exposure to these air pollutants. Copyright © 2011 Elsevier Ltd. All rights reserved.
A critical evaluation of a flow cytometer used for detecting enterococci in recreational waters.
King, Dawn N; Brenner, Kristen P; Rodgers, Mark R
2007-06-01
The current U. S. Environmental Protection Agency-approved method for enterococci (Method 1600) in recreational water is a membrane filter (MF) method that takes 24 hours to obtain results. If the recreational water is not in compliance with the standard, the risk of exposure to enteric pathogens may occur before the water is identified as hazardous. Because flow cytometry combined with specific fluorescent antibodies has the potential to be used as a rapid detection method for microorganisms, this technology was evaluated as a rapid, same-day method to detect enterococci in bathing beach waters. The flow cytometer chosen for this study was a laser microbial detection system designed to detect labeled antibodies. A comparison of MF counts with flow cytometry counts of enterococci in phosphate buffer and sterile-filtered recreational water showed good agreement between the two methods. However, when flow cytometry was used, the counts were several orders of magnitude higher than the MF counts with no correlation to Enterococcus spike concentrations. The unspiked sample controls frequently had higher counts than the samples spiked with enterococci. Particles within the spiked water samples were probably counted as target cells by the flow cytometer because of autofluorescence or non-specific adsorption of antibody and carryover to subsequent samples. For these reasons, this technology may not be suitable for enterococci detection in recreational waters. Improvements in research and instrument design that will eliminate high background and carryover may make this a viable technology in the
2015-07-01
samples must be thoroughly degreased and dried to eliminate any outgassing from organic contamination and water. Samples can be cleaned ultrasonically ...in an ultrasonic bath for at least 10 minutes to ensure separation of particles (University of California, Riverside, n.d.). These solutions can...be further agitated in the ultrasonic bath to separate particles. It should be noted that excessive ultrasonic agitation can damage samples
NASA Astrophysics Data System (ADS)
Nyoka, M.; Akdogan, G.; Eric, R. H.; Sutcliffe, N.
2003-12-01
The process of mixing and solid-liquid mass transfer in a one-fifth scale water model of a 100-ton Creusot-Loire Uddeholm (CLU) converter was investigated. The modified Froude number was used to relate gas flow rates between the model and its protoype. The influences of gas flow rate between 0.010 and 0.018 m3/s and bath height from 0.50 to 0.70 m on mixing time were examined. The results indicated that mixing time decreased with increasing gas flow rate and increased with increasing bath height. The mixing time results were evaluated in terms of specific energy input and the following correlation was proposed for estimating mixing times in the model CLU converter: T mix=1.08Q -1.05 W 0.35, where Q (m3/s) is the gas flow rate and W (tons) is the model bath weight. Solid-liquid mass-transfer rates from benzoic acid specimens immersed in the gas-agitated liquid phase were assessed by a weight loss measurement technique. The calculated mass-transfer coefficients were highest at the bath surface reaching a value of 6.40 × 10-5 m/s in the sprout region. Mass-transfer coefficients and turbulence parameters decreased with depth, reaching minimum values at the bottom of the vessel.
Estimating heat tolerance of plants by ion leakage: a new method based on gradual heating.
Ilík, Petr; Špundová, Martina; Šicner, Michal; Melkovičová, Helena; Kučerová, Zuzana; Krchňák, Pavel; Fürst, Tomáš; Večeřová, Kristýna; Panzarová, Klára; Benediktyová, Zuzana; Trtílek, Martin
2018-05-01
Heat tolerance of plants related to cell membrane thermostability is commonly estimated via the measurement of ion leakage from plant segments after defined heat treatment. To compare heat tolerance of various plants, it is crucial to select suitable heating conditions. This selection is time-consuming and optimizing the conditions for all investigated plants may even be impossible. Another problem of the method is its tendency to overestimate basal heat tolerance. Here we present an improved ion leakage method, which does not suffer from these drawbacks. It is based on gradual heating of plant segments in a water bath or algal suspensions from room temperature up to 70-75°C. The electrical conductivity of the bath/suspension, which is measured continuously during heating, abruptly increases at a certain temperature T COND (within 55-70°C). The T COND value can be taken as a measure of cell membrane thermostability, representing the heat tolerance of plants/organisms. Higher T COND corresponds to higher heat tolerance (basal or acquired) connected to higher thermostability of the cell membrane, as evidenced by the common ion leakage method. The new method also enables determination of the thermostability of photochemical reactions in photosynthetic samples via the simultaneous measurement of Chl fluorescence. © 2018 The Authors. New Phytologist © 2018 New Phytologist Trust.
Method of freezing living cells and tissues with improved subsequent survival
Senkan, Selim M.; Hirsch, Gerald P.
1980-01-01
This invention relates to an improved method for freezing red blood cells, ther living cells, or tissues with improved subsequent survival, wherein constant-volume freezing is utilized that results in significantly improved survival compared with constant-pressure freezing; optimization is attainable through the use of different vessel geometries, cooling baths and warming baths, and sample concentrations.
Effects of vasopressin on the isolated perfused human collecting tubule.
Yanagawa, N; Trizna, W; Bar-Khayim, Y; Fine, L G
1981-05-01
Cortical collecting tubules (CCT) were dissected from the surviving normal tissue of human kidneys removed at operation for either carcinoma or calculus. These CCT's were perfused in vitro shortly after the nephrectomy was performed. Transtubular potential differences in different tubules varied from +3.2 to -2.0 mV and were reduced towards zero by lowering the temperature or by adding ouabain to the bath. In the absence of vasopressin, tubules were essentially impermeable to water with extremely low net water fluxes even in the presence of a transtubular osmotic gradient. Addition of vasopressin to the bath caused the transtubular osmotic water permeability coefficient to increase to values of 125, 175, and 155 X 10(-4) cm/sec in three tubules thus studied. These results demonstrate close similarities between the human CCT and the more extensively studied rabbit CCT.
Elahi, Ehsan; Zhang, Liqin; Abid, Muhammad; Javed, Muhammad Tariq; Xinru, Han
2017-03-01
The use of wastewater for rearing domestic animals is a common phenomenon in most of the developing countries like Pakistan that face a serious shortage of freshwater resources. However, most of the literature has only focused on the indirect effects of wastewater use on animal health or productivity, and literature on the direct effects of wastewater use is rare. Therefore, this study aims to investigate the direct and indirect effects of wastewater usage on the prevalence of animal diseases and animal health in Pakistan. The study is based on a household-level survey of 360 domestic water buffalo herds collected from 12 districts of Punjab Province, Pakistan. We tested the prevalence of the animal's diseases, animal's health, and wastewater-use preference with various econometric tools, such as the Poisson, negative binomial, and logistic regressions. The findings of the study show that the majority of the farmers use wastewater for buffalo bathing due to the shortage of freshwater resources. Results explore the prevalence of diseases such as clinical mastitis, tick infestation, and foot and mouth disease at the farm level significantly associated with buffalo bathing in the wastewater. Moreover, bathing in wastewater pre- and post-milking also plays a role in the occurrence of diseases. Particularly, if the buffalo's access to wastewater for bathing is within 60 min after milking, the probability of the animals being exposed to mastitis is higher. Furthermore, on investigation, a number of factors are found, such as the distance to the water source, power shortage, groundwater availability, and the education of farmers that influence farmers' behavior of letting their animals take a bath in wastewater. Moreover, the use of different preventive measures improves the animal's health.
Balneotherapy in treatment of spastic upper limb after stroke.
Erceg-Rukavina, Tatjana; Stefanovski, Mihajlo
2015-02-01
After stroke, spasticity is often the main problem that prevents functional recovery. Pain occurs in up to 70% of patients during the first year post-stroke. A total of 70 patients (30 female and 45 male) mean age (65.67) participated in prospective, controlled study. ischaemic stroke, developed spasticity of upper limb, post-stroke interval <6 months. contraindications for balneotherapy and inability to follow commands. Experimental group (Ex) (n=35) was treated with sulphurous baths (31°-33°C) and controlled group (Co) with taped water baths, during 21 days. All patients were additionally treated with kinesitherapy and cryotherapy. The outcome was evaluated using Modified Ashworth scale for spasticity and VAS scale for pain. The significance value was sat at p<0.05. To find out the effects of balneotherapy with sulphurous bath on spasticity and pain in affected upper limb. Reduction in tone of affected upper limb muscles was significant in Ex group (p<0.05). Pain decreased significantly in Ex-group (p<0.01). Our results show that balneotherapy with sulphurous water reduces spasticity and pain significantly and can help in treatment of post-stroke patients.
Chen, Lipeng; Gelin, Maxim F; Chernyak, Vladimir Y; Domcke, Wolfgang; Zhao, Yang
2016-12-16
The effect of a dissipative environment on the ultrafast nonadiabatic dynamics at conical intersections is analyzed for a two-state two-mode model chosen to represent the S 2 (ππ*)-S 1 (nπ*) conical intersection in pyrazine (the system) which is bilinearly coupled to infinitely many harmonic oscillators in thermal equilibrium (the bath). The system-bath coupling is modeled by the Drude spectral function. The equation of motion for the reduced density matrix of the system is solved numerically exactly with the hierarchy equation of motion method using graphics-processor-unit (GPU) technology. The simulations are valid for arbitrary strength of the system-bath coupling and arbitrary bath memory relaxation time. The present computational studies overcome the limitations of weak system-bath coupling and short memory relaxation time inherent in previous simulations based on multi-level Redfield theory [A. Kühl and W. Domcke, J. Chem. Phys. 2002, 116, 263]. Time evolutions of electronic state populations and time-dependent reduced probability densities of the coupling and tuning modes of the conical intersection have been obtained. It is found that even weak coupling to the bath effectively suppresses the irregular fluctuations of the electronic populations of the isolated two-mode conical intersection. While the population of the upper adiabatic electronic state (S 2 ) is very efficiently quenched by the system-bath coupling, the population of the diabatic ππ* electronic state exhibits long-lived oscillations driven by coherent motion of the tuning mode. Counterintuitively, the coupling to the bath can lead to an enhanced lifetime of the coherence of the tuning mode as a result of effective damping of the highly excited coupling mode, which reduces the strong mode-mode coupling inherent to the conical intersection. The present results extend previous studies of the dissipative dynamics at conical intersections to the nonperturbative regime of system-bath coupling. They pave the way for future first-principles simulations of femtosecond time-resolved four-wave-mixing spectra of chromophores in condensed phases which are nonperturbative in the system dynamics, the system-bath coupling as well as the field-matter coupling.
A maximum entropy thermodynamics of small systems.
Dixit, Purushottam D
2013-05-14
We present a maximum entropy approach to analyze the state space of a small system in contact with a large bath, e.g., a solvated macromolecular system. For the solute, the fluctuations around the mean values of observables are not negligible and the probability distribution P(r) of the state space depends on the intricate details of the interaction of the solute with the solvent. Here, we employ a superstatistical approach: P(r) is expressed as a marginal distribution summed over the variation in β, the inverse temperature of the solute. The joint distribution P(β, r) is estimated by maximizing its entropy. We also calculate the first order system-size corrections to the canonical ensemble description of the state space. We test the development on a simple harmonic oscillator interacting with two baths with very different chemical identities, viz., (a) Lennard-Jones particles and (b) water molecules. In both cases, our method captures the state space of the oscillator sufficiently well. Future directions and connections with traditional statistical mechanics are discussed.
Osmosis in Cortical Collecting Tubules
Schafer, James A.; Patlak, Clifford S.; Andreoli, Thomas E.
1974-01-01
This paper reports a theoretical analysis of osmotic transients and an experimental evaluation both of rapid time resolution of lumen to bath osmosis and of bidirectional steady-state osmosis in isolated rabbit cortical collecting tubules exposed to antidiuretic hormone (ADH). For the case of a membrane in series with unstirred layers, there may be considerable differences between initial and steady-state osmotic flows (i.e., the osmotic transient phenomenon), because the solute concentrations at the interfaces between membrane and unstirred layers may vary with time. A numerical solution of the equation of continuity provided a means for computing these time-dependent values, and, accordingly, the variation of osmotic flow with time for a given set of parameters including: Pf (cm s–1), the osmotic water permeability coefficient, the bulk phase solute concentrations, the unstirred layer thickness on either side of the membrane, and the fractional areas available for volume flow in the unstirred layers. The analyses provide a quantitative frame of reference for evaluating osmotic transients observed in epithelia in series with asymmetrical unstirred layers and indicate that, for such epithelia, Pf determinations from steady-state osmotic flows may result in gross underestimates of osmotic water permeability. In earlier studies, we suggested that the discrepancy between the ADH-dependent values of Pf and PDDw (cm s–1, diffusional water permeability coefficient) was the consequence of cellular constraints to diffusion. In the present experiments, no transients were detectable 20–30 s after initiating ADH-dependent lumen to bath osmosis; and steady-state ADH-dependent osmotic flows from bath to lumen and lumen to bath were linear and symmetrical. An evaluation of these data in terms of the analytical model indicates: First, cellular constraints to diffusion in cortical collecting tubules could be rationalized in terms of a 25-fold reduction in the area of the cell layer available for water transport, possibly due in part to transcellular shunting of osmotic flow; and second, such cellular constraints resulted in relatively small, approximately 15%, underestimates of Pf. PMID:4846767
Nanocomposite copolymer thin-film sensor for detection of escherichia coli
NASA Astrophysics Data System (ADS)
Mathur, Prafull; Misra, S. C. K.; Yadav, Maneesha; Bawa, S. S.; Gupta, A. K.
2006-01-01
The majority of human diseases associated with microbial contaminated water are infectious in nature and the associated pathogen includes bacteria, fungi, viruses and protozoa. Water contaminated with bacteria can cause a number of food-borne and water-borne diseases. The waterborne transmission is highly effective means of spreading infectious agents to a large portion of population; this includes water and milk too. Waterborne infections are recognized as resulting either from ingestion of contaminated water or ice, food items, which have, came into contact with microbial contaminated water (occurring through bathing and recreational activities) etc. The detection of E. coli in food and water is normally carried out by culturing methods, which normally take 3-6 days, These methods are complicated and time-consuming in spite of their correctness, and cannot easily meet inspection demands on E. coli. Hence, an establishment of rapid detection methods for E. coli is strongly required. We have developed highly sensitive and cost effective solid sate sensors prepared from vacuum evaporated thin films of nanocomposite copolymer detection of presence of E. coli vapors in the air within 20 seconds. These sensors operate at room temperature. The preparation, optical, electrical, and structural characterization and behavioral acceptance test on the microorganism sensing properties of these sensors are reported here.
Rapid and sensitive detection of canine parvovirus type 2 by recombinase polymerase amplification.
Wang, Jianchang; Liu, Libing; Li, Ruiwen; Wang, Jinfeng; Fu, Qi; Yuan, Wanzhe
2016-04-01
A novel recombinase polymerase amplification (RPA)-based method for detection of canine parvovirus type 2 (CPV-2) was developed. Sensitivity analysis showed that the detection limit of RPA was 10 copies of CPV-2 genomic DNA. RPA amplified both CPV-2a and -2b DNA but did not amplify the template of other important dog viruses (CCoV, PRV or CDV), demonstrating high specificity. The method was further validated with 57 canine fecal samples. An outstanding advantage of RPA is that it is an isothermal reaction and can be performed in a water bath, making RPA a potential alternative method for CPV-2 detection in resource-limited settings.
MUTAGENICITY AND MUTATION SPECTRA OF AIR AND WATER: ROLE OF GSST1-1 AND AKR GENOTYPES
Recent molecular epidemiology research confirms that an increased risk for bladder cancer is associated with dermal/inhalation exposure to chlorinated water (from bathing/showering and/or swimming), rather than to drinking the water, and that risk is enhanced in people carrying a...
Reproducible insulin secretion from isolated rat pancreas preparations using an organ bath.
Morita, Asuka; Ouchi, Motoshi; Terada, Misao; Kon, Hiroe; Kishimoto, Satoko; Satoh, Keitaro; Otani, Naoyuki; Hayashi, Keitaro; Fujita, Tomoe; Inoue, Ken-Ichi; Anzai, Naohiko
2018-02-09
Diabetes mellitus is a lifestyle-related disease that is characterized by inappropriate or diminished insulin secretion. Ex vivo pharmacological studies of hypoglycemic agents are often conducted using perfused pancreatic preparations. Pancreas preparations for organ bath experiments do not require cannulation and are therefore less complex than isolated perfused pancreas preparations. However, previous research has generated almost no data on insulin secretion from pancreas preparations using organ bath preparations. The purpose of this study was to investigate the applicability of isolated rat pancreas preparations using the organ bath technique in the quantitative analysis of insulin secretion from β-cells. We found that insulin secretion significantly declined during incubation in the organ bath, whereas it was maintained in the presence of 1 µM GLP-1. Conversely, amylase secretion exhibited a modest increase during incubation and was not altered in the presence of GLP-1. These results demonstrate that the pancreatic organ bath preparation is a sensitive and reproducible method for the ex vivo assessment of the pharmacological properties of hypoglycemic agents.
Spallation yield of neutrons produced in thick lead target bombarded with 250 MeV protons
NASA Astrophysics Data System (ADS)
Chen, L.; Ma, F.; Zhanga, X. Y.; Ju, Y. Q.; Zhang, H. B.; Ge, H. L.; Wang, J. G.; Zhou, B.; Li, Y. Y.; Xu, X. W.; Luo, P.; Yang, L.; Zhang, Y. B.; Li, J. Y.; Xu, J. K.; Liang, T. J.; Wang, S. L.; Yang, Y. W.; Gu, L.
2015-01-01
The neutron yield from thick target of Pb irradiated with 250 MeV protons has been studied experimentally. The neutron production was measured with the water-bath gold method. The thermal neutron distributions in the water were determined according to the measured activities of Au foils. Corresponding results calculated with the Monte Carlo code MCNPX were compared with the experimental data. It was found out that the Au foils with cadmium cover significantly changed the spacial distribution of the thermal neutron field. The corrected neutron yield was deduced to be 2.23 ± 0.19 n/proton by considering the influence of the Cd cover on the thermal neutron flux.
The USEPA Beaches Environmental Assessment and Coastal Health Act (BEACH Act) requires states to develop monitoring and notification programs for recreational waters using approved bacterial indicators. Implementation of an appropriate monitoring program can, under some circumsta...
METHOD OF APPLYING COPPER COATINGS TO URANIUM
Gray, A.G.
1959-07-14
A method is presented for protecting metallic uranium, which comprises anodic etching of the uranium in an aqueous phosphoric acid solution containing chloride ions, cleaning the etched uranium in aqueous nitric acid solution, promptly electro-plating the cleaned uranium in a copper electro-plating bath, and then electro-plating thereupon lead, tin, zinc, cadmium, chromium or nickel from an aqueous electro-plating bath.
NASA Astrophysics Data System (ADS)
Richter, Martin; Fingerhut, Benjamin P.
2017-06-01
The description of non-Markovian effects imposed by low frequency bath modes poses a persistent challenge for path integral based approaches like the iterative quasi-adiabatic propagator path integral (iQUAPI) method. We present a novel approximate method, termed mask assisted coarse graining of influence coefficients (MACGIC)-iQUAPI, that offers appealing computational savings due to substantial reduction of considered path segments for propagation. The method relies on an efficient path segment merging procedure via an intermediate coarse grained representation of Feynman-Vernon influence coefficients that exploits physical properties of system decoherence. The MACGIC-iQUAPI method allows us to access the regime of biological significant long-time bath memory on the order of hundred propagation time steps while retaining convergence to iQUAPI results. Numerical performance is demonstrated for a set of benchmark problems that cover bath assisted long range electron transfer, the transition from coherent to incoherent dynamics in a prototypical molecular dimer and excitation energy transfer in a 24-state model of the Fenna-Matthews-Olson trimer complex where in all cases excellent agreement with numerically exact reference data is obtained.
Characteristic functions of quantum heat with baths at different temperatures
NASA Astrophysics Data System (ADS)
Aurell, Erik
2018-06-01
This paper is about quantum heat defined as the change in energy of a bath during a process. The presentation takes into account recent developments in classical strong-coupling thermodynamics and addresses a version of quantum heat that satisfies quantum-classical correspondence. The characteristic function and the full counting statistics of quantum heat are shown to be formally similar. The paper further shows that the method can be extended to more than one bath, e.g., two baths at different temperatures, which opens up the prospect of studying correlations and heat flow. The paper extends earlier results on the expected quantum heat in the setting of one bath [E. Aurell and R. Eichhorn, New J. Phys. 17, 065007 (2015), 10.1088/1367-2630/17/6/065007; E. Aurell, Entropy 19, 595 (2017), 10.3390/e19110595].
Armenta, Roberto E; Burja, Adam; Radianingtyas, Helia; Barrow, Colin J
2006-12-27
A variety of techniques for extracting carotenoids from the marine Thraustochytrium sp. ONC-T18 was compared. Specifically, the organic solvents acetone, ethyl acetate, and petroleum ether were tested, along with direct and indirect ultrasonic assisted extraction (probe vs bath) methods. Techniques that used petroleum ether/acetone/water (15:75:10, v/v/v) with 3 h of agitation, or 5 min in an ultrasonic bath, produced the highest extraction yields of total carotenoids (29-30.5 microg g-1). Concentrations up to 11.5 microg g-1 of canthaxanthin and 17.5 microg g-1 of beta;-carotene were detected in extracts stored for 6 weeks. Astaxanthin and echinenone were also detected as minor compounds. Extracts with and without antioxidants showed similar carotenoid concentration profiles. However, total carotenoid concentrations were approximately 8% higher when antioxidants were used. Finally, an easy-to-perform and inexpensive method to detect co-enzymes in ONC-T18 was also developed using silica gel TLC plates. Five percent methanol in toluene as a mobile phase consistently eluted co-enzyme Q10 standards and could separate the co-enzyme fractions present in ONC-T18.
Hydromonochord: Visualizing String Vibration by Water Swirls
ERIC Educational Resources Information Center
Sommer, Wilfried; Meier-Boke, Ralf; Meinzer, Nicholas
2010-01-01
The hydromonochord is a horizontal vibrating string that just makes contact with the surface of a water bath. The motion of the string sets up a pattern of swirls on the surface of the water, thus complementing the usual pattern of nodes and antinodes. The device is based on the traditional monochord. A water basin (Fig. 1) has two slits in the…
Chou, Chung-Lin; Yu, Ming-Jiun; Kassai, Eliza M; Morris, Ryan G; Hoffert, Jason D; Wall, Susan M; Knepper, Mark A
2008-07-01
Collecting duct cells swell when exposed to arginine vasopressin (AVP) in the presence of a transepithelial osmolality gradient. We investigated the mechanisms of AVP-induced cell swelling in isolated, perfused rat inner medullary collecting ducts (IMCDs) using quantitative video microscopy and fluorescence-based measurements of transepithelial water transport. We tested the roles of transepithelial water flow, basolateral solute entry, and the cytoskeleton (actomyosin). When a transepithelial osmolality gradient was imposed by addition of NaCl to the bath, AVP significantly increased both water flux and cell height. When the osmolality gradient was imposed by addition of mannitol, AVP increased water flux but not cell height, suggesting that AVP-induced cell swelling requires a NaCl gradient and is not merely dependent on the associated water flux. Bumetanide (Na-K-2Cl cotransporter inhibitor) added to the bath markedly diminished the AVP-induced cell height increase. AVP-induced cell swelling was absent in IMCDs from NKCC1-knockout mice. In rat IMCDs, replacement of Na, K, or Cl in the peritubular bath caused significant cell shrinkage, consistent with a basolateral solute transport pathway dependent on all three ions. Immunocytochemistry using an antibody to NKCC1 confirmed basolateral expression in IMCD cells. The conventional nonmuscle myosin II inhibitor blebbistatin also diminished the AVP-induced cell height increase and cell shape change, consistent with a role for the actin cytoskeleton and myosin II. We conclude that the AVP-induced cell height increase is dependent on basolateral solute uptake via NKCC1 and changes in actin organization via myosin II, but is not dependent specifically on increased apical water entry.
Survey of Naegleria fowleri in geothermal recreational waters of Guadeloupe (French West Indies).
Moussa, Mirna; De Jonckheere, Johan F; Guerlotté, Jérôme; Richard, Vincent; Bastaraud, Alexandra; Romana, Marc; Talarmin, Antoine
2013-01-01
In 2008 a fatal case of primary amoebic meningoencephalitis, due to the amoeboflagellate Naegleria fowleri, occurred in Guadeloupe, French West Indies, after a child swam in a bath fed with geothermal water. In order to improve the knowledge on free-living amoebae in this tropical part of France, we investigated on a monthly basis, the presence of Naegleria spp. in the recreational baths, and stream waters which feed them. A total of 73 water samples, 48 sediments and 54 swabs samples were collected from 6 sampling points between June 2011 and July 2012. The water samples were filtered and the filters transferred to non-nutrient agar plates seeded with a heat-killed suspension of Escherichia coli while sediment and swab samples were placed directly on these plates. The plates were incubated at 44°C for the selective isolation of thermophilic Naegleria. To identify the Naegleria isolates the internal transcribed spacers, including the 5.8S rDNA, were amplified by polymerase chain reaction and the sequence of the PCR products was determined. Thermophilic amoebae were present at nearly all collection sites. The pathogenic N. fowleri was the most frequently encountered thermophilic species followed by N. lovaniensis. The concentration of N. fowleri was rather low in most water samples, ranging from 0 to 22 per liter. Sequencing revealed that all N. fowleri isolates belonged to a common Euro-American genotype, the same as detected in the human case in Guadeloupe. These investigations need to be continued in order to counsel the health authorities about prevention measures, because these recreational thermal baths are used daily by local people and tourists.
Survey of Naegleria fowleri in Geothermal Recreational Waters of Guadeloupe (French West Indies)
Moussa, Mirna; De Jonckheere, Johan F.; Guerlotté, Jérôme; Richard, Vincent; Bastaraud, Alexandra; Romana, Marc; Talarmin, Antoine
2013-01-01
In 2008 a fatal case of primary amoebic meningoencephalitis, due to the amoeboflagellate Naegleria fowleri, occurred in Guadeloupe, French West Indies, after a child swam in a bath fed with geothermal water. In order to improve the knowledge on free-living amoebae in this tropical part of France, we investigated on a monthly basis, the presence of Naegleria spp. in the recreational baths, and stream waters which feed them. A total of 73 water samples, 48 sediments and 54 swabs samples were collected from 6 sampling points between June 2011 and July 2012. The water samples were filtered and the filters transferred to non-nutrient agar plates seeded with a heat-killed suspension of Escherichia coli while sediment and swab samples were placed directly on these plates. The plates were incubated at 44°C for the selective isolation of thermophilic Naegleria. To identify the Naegleria isolates the internal transcribed spacers, including the 5.8S rDNA, were amplified by polymerase chain reaction and the sequence of the PCR products was determined. Thermophilic amoebae were present at nearly all collection sites. The pathogenic N. fowleri was the most frequently encountered thermophilic species followed by N. lovaniensis. The concentration of N. fowleri was rather low in most water samples, ranging from 0 to 22 per liter. Sequencing revealed that all N. fowleri isolates belonged to a common Euro-American genotype, the same as detected in the human case in Guadeloupe. These investigations need to be continued in order to counsel the health authorities about prevention measures, because these recreational thermal baths are used daily by local people and tourists. PMID:23349880
Xu, Li; Wu, Lin; Liu, Tingting; Xing, Wenrong; Cao, Xinsheng; Zhang, Shu; Su, Zongyi
2017-01-01
[Purpose] The aim of our study was to explore the changes in the blood of servicemen in sub-health conditions during a 21-day balneotherapy program. [Subjects and Methods] For this study, 129 servicemen in sub-health condition were recruited. The subjects were randomly divided into either the balneotherapy group (70) or the control group (59). Subjects in the balneotherapy group received whole-body immersion bath therapy in thermomineral water (30 min daily) for 21 days. Their blood samples were examined 1 day before and after balneotherapy. The parameters studied included mean corpuscular hemoglobin (MCH), mean corpuscular hemoglobin concentration (MCHC), white blood cell (WBC), lactic acid (LAC), alanine aminotransferase (ALT), glucose (GLU), and triglycerides (TG) levels. [Results] After 21 days of balneotherapy, MCH levels and MCHC increased significantly and WBC counts increased significantly. LAC levels decreased significantly. ALT, GLU, and TG levels decreased significantly. In the control group, there were no statistical differences before and after tap water baths following the same procedure. [Conclusion] A 21-day balneotherapy program significantly improved blood cell counts and blood biochemical indexes and reduced ponogen levels in servicemen in sub-health condition. PMID:28931990
Effects of microwaves on the colony-forming capacity of haemopoietic stem cells in mice.
Rotkovská, D; Vacek, A; Bartonícková, A
1987-01-01
A suspension of bone marrow cells from femurs of female (CBA X C57Bl)F1 mice was exposed to 2450 MHz CW microwaves in a specially designed waveguide exposure system. The temperature of the suspension rose, during exposure to microwaves, from 20 degrees C to 45 degrees C, and at an interval within 20 degrees C to 45 degrees C the number of haemopoietic stem cells (CFUs) was determined by the spleen exocolony method. The time of exposure of bone marrow cells to each temperature studied was 20 s. Control suspensions of bone marrow cells were exposed to a water bath temperature. There were no significant effects of the CFUs with the water bath temperature, while after exposure to microwaves the number of spleen colonies was elevated with a nadir at the temperature of 37 degrees C. With a microwave-induced increase of the temperature above 41 degrees C the number of CFUs in the bone marrow suspension decreased. The increase in the number of colonies was related to the rise in the seeding rate of the CFUs as well as to a rise in their proliferative activity, while the drop in the number of colonies was influenced also by heat-killing of the CFUs by microwave exposure.
Protein electron transfer: is biology (thermo)dynamic?
NASA Astrophysics Data System (ADS)
Matyushov, Dmitry V.
2015-12-01
Simple physical mechanisms are behind the flow of energy in all forms of life. Energy comes to living systems through electrons occupying high-energy states, either from food (respiratory chains) or from light (photosynthesis). This energy is transformed into the cross-membrane proton-motive force that eventually drives all biochemistry of the cell. Life’s ability to transfer electrons over large distances with nearly zero loss of free energy is puzzling and has not been accomplished in synthetic systems. The focus of this review is on how this energetic efficiency is realized. General physical mechanisms and interactions that allow proteins to fold into compact water-soluble structures are also responsible for a rugged landscape of energy states and a broad distribution of relaxation times. Specific to a protein as a fluctuating thermal bath is the protein-water interface, which is heterogeneous both dynamically and structurally. The spectrum of interfacial fluctuations is a consequence of protein’s elastic flexibility combined with a high density of surface charges polarizing water dipoles into surface nanodomains. Electrostatics is critical to the protein function and the relevant questions are: (i) What is the spectrum of interfacial electrostatic fluctuations? (ii) Does the interfacial biological water produce electrostatic signatures specific to proteins? (iii) How is protein-mediated chemistry affected by electrostatics? These questions connect the fluctuation spectrum to the dynamical control of chemical reactivity, i.e. the dependence of the activation free energy of the reaction on the dynamics of the bath. Ergodicity is often broken in protein-driven reactions and thermodynamic free energies become irrelevant. Continuous ergodicity breaking in a dense spectrum of relaxation times requires using dynamically restricted ensembles to calculate statistical averages. When applied to the calculation of the rates, this formalism leads to the nonergodic activated kinetics, which extends the transition-state theory to dynamically dispersive media. Releasing the grip of thermodynamics in kinetic calculations through nonergodicity provides the mechanism for an efficient optimization between reaction rates and the spectrum of relaxation times of the protein-water thermal bath. Bath dynamics, it appears, play as important role as the free energy in optimizing biology’s performance.
Jorge, Janaina Habib; Giampaolo, Eunice Teresinha; Vergani, Carlos Eduardo; Machado, Ana Lúcia; Pavarina, Ana Cláudia; Carlos, Iracilda Zeppone
2004-01-01
This study compared the effect of two postpolymerization heat treatments on the cytotoxicity of three denture base resins on L929 cells using 3H-thymidine incorporation and MTT assays. Sample disks of Lucitone 550, QC 20, and Acron MC resins were fabricated under aseptic conditions and stored in distilled water at 37 degrees C for 48 hours. Specimens were then divided into three groups: (1) heat treated in microwave oven for 3 minutes at 500 W; (2) heat treated in water bath at 55 degrees C for 60 minutes; and (3) no heat treatment. Eluates were prepared by placing three disks into a sterile glass vial with 9 mL of Eagle's medium and incubating at 37 degrees C for 24 hours. The cytotoxic effect from the eluates was evaluated using the 3H-thymidine incorporation and MTT assays, which reflect DNA synthesis levels and cell metabolism, respectively. The components leached from the resins were cytotoxic to L929 cells when 3H-thymidine incorporation assay was employed. In contrast, eluates from all resins revealed noncytotoxic effects as measured by MTT assay. For both MTT assay and 3H-thymidine incorporation, the heat treatments did not decrease the cytotoxicity of the materials tested. Resins were graded by 3H-thymidine incorporation assay as slightly cytotoxic and by MTT assay as noncytotoxic. Cytotoxicity of the denture base materials was not influenced by microwave or water bath heat treatment.
Deposition of radon progeny on skin surfaces and resulting radiation doses in radon therapy.
Tempfer, H; Hofmann, W; Schober, A; Lettner, H; Dinu, A L
2010-05-01
In the Gastein valley, Austria, radon-rich thermal water and air have been used for decades for the treatment of various diseases. To explore the exposure pathway of radon progeny adsorbed to the skin, progeny activities on the skin of patients exposed to thermal water (in a bathtub) and hot vapour (in a vapour chamber) were measured by alpha spectrometry. Average total alpha activities on the patients' skin varied from 1.2 to 4.1 Bq/cm(2) in the bathtub, and from 1.1 to 2.6 Bq/cm(2) in the vapour bath. Water pH-value and ion concentration did affect radon progeny adsorption on the skin, whereas skin greasiness and blood circulation did not. Measurements of the penetration of deposited radon progeny into the skin revealed a roughly exponential activity distribution in the upper layers of the skin. Based on the radon progeny surface activity concentrations and their depth distributions, equivalent doses to different layers of the skin, in particular to the Langerhans cells located in the epidermis, ranged from 0.12 mSv in the thermal bath to 0.33 mSv in the vapour bath, exceeding equivalent doses to the inner organs (kidneys) by inhaled radon and progeny by about a factor 3, except for the lung, which receives the highest doses via inhalation. These results suggest that radon progeny attachment on skin surfaces may play a major role in the dosimetry for both thermal water and hot vapour treatment schemes.
Odorless inhalant toxic encephalopathy in developing countries household: Gas geyser syndrome
Mehta, Anish; Mahale, Rohan; John, Aju Abraham; Abbas, Masoom Mirza; Javali, Mahendra; Acharya, Purushottam; Rangasetty, Srinivasa
2016-01-01
Background: Liquefied petroleum gas geysers are used very frequently for heating water in developing countries such as India. However, these gas geysers emit various toxic gases; one among them is colorless, odorless carbon monoxide (CO). In the past few years, there were reports of unexplained loss of consciousness in the bathroom. However, the exact cause for these episodes has been recognized as toxic encephalopathy due to toxic gases inhalation mainly CO. Objective: To analyze the clinical profile and outcome of patients brought with loss of consciousness in the bathroom while bathing using gas geyser. Materials and Methods: Case records of patients with the diagnosis of gas geyser syndrome from 2013 to 2015 were retrieved and analyzed. Twenty-four cases were identified and included in the study. This was a retrospective, descriptive study. Results: Twenty-four patients were brought to our Emergency Department with loss of consciousness in the bathroom while bathing. Twenty-one cases had loss of consciousness during bathing and recovered spontaneously. Two cases were found dead in the bathroom and were brought to the Department of Forensic Medicine for postmortem. One case was brought in deep altered state of consciousness and succumbed to illness within 1 week. Conclusion: Awareness regarding CO intoxication due to usage of ill-fitted, ill-ventilated gas geyser is necessary as they are entirely preventable conditions. PMID:27114653
THE EVOLUTION OF WATER QUALITY IN THE UNITED STATES - 1922-2003
The microbiological quality of recreational waters was first discussed in the United States as early as 1922 by the American Public Health Association's Committee on Bathing Beaches (APHA,1922) . The Committee surveyed 2000 physicians and state health officials inquiring about th...
Györy, A Z; Roby, H
1977-01-01
1. With the aid of micropuncture techniques, proximal tubular transepithelial concentration differences for Na (deltaC Na) and chloride (deltaC Cl) were measured in kidney cortex slices at bathing fluid Na concentrations from 10 to 400 m-mole. kg-1. Tissue content of water, Na and K was also measured in such slices. Under steady-state conditions of zero net flux of NaCl and water, deltaC Na represents the sum of active Na transport, factored by the tubular permeability coefficient added to a component of flux due to electrical forces. 2. The relation between bathing fluid Na concentraton and deltaC Na appeared sigmoid in form suggesting an allosteric mechanism for the transport step. 3. Transtubular potential difference, calculated from transepithelial Cl distribution ratios, did not appear constant at the various bathing fluid Na concentrations. Correcting for the effect of these potential differences on the value of each deltaC Na did not convert the sigmoid transport curve to a hyperbolic one, confirming the suggested allosteric nature of the active Na transport step. 4. Intracellular Na content varied linearly with bathing fluid Na concentrations implying free entry of this cation into the cell. This also suggests that the sigmoid transport curve is related to the properties of the active Na transport pump. PMID:856986
Code of Federal Regulations, 2014 CFR
2014-07-01
... means the water, solvent, or other chemical bath into which the polymer or prepolymer (partially reacted..., transportation, collection, concentration, and purification of organic solvents. It may include enclosures, hoods...
Code of Federal Regulations, 2010 CFR
2010-07-01
... means the water, solvent, or other chemical bath into which the polymer or prepolymer (partially reacted..., transportation, collection, concentration, and purification of organic solvents. It may include enclosures, hoods...
Code of Federal Regulations, 2013 CFR
2013-07-01
... means the water, solvent, or other chemical bath into which the polymer or prepolymer (partially reacted..., transportation, collection, concentration, and purification of organic solvents. It may include enclosures, hoods...
Code of Federal Regulations, 2012 CFR
2012-07-01
... means the water, solvent, or other chemical bath into which the polymer or prepolymer (partially reacted..., transportation, collection, concentration, and purification of organic solvents. It may include enclosures, hoods...
Code of Federal Regulations, 2011 CFR
2011-07-01
... means the water, solvent, or other chemical bath into which the polymer or prepolymer (partially reacted..., transportation, collection, concentration, and purification of organic solvents. It may include enclosures, hoods...
The United States Environmental Protection Agency (US EPA) and its predecessors have conducted three distinct series of epidemiological studies beginning in 1948 on the relationship between bathing water quality and swimmers' illnesses. Keeping pace with advances in microbial tec...
NASA Astrophysics Data System (ADS)
Kälsch, Julia; Pott, Leona L.; Takeda, Atsushi; Kumamoto, Hideo; Möllmann, Dorothe; Canbay, Ali; Sitek, Barbara; Baba, Hideo A.
2017-04-01
Beneficial effects of balneotherapy using naturally occurring carbonated water (CO2 enriched) have been known since the Middle Ages. Although this therapy is clinically applied for peripheral artery disease and skin disorder, the underlying mechanisms are not fully elucidated.
Microbial risk assessment with the OAEL approach at water abstraction points in rural Kenya
NASA Astrophysics Data System (ADS)
Yillia, Paul T.; Kreuzinger, Norbert; Mathooko, Jude M.; Ndomahina, Ernest T.
US-based models for recreational water quality were applied to characterize the potential health risk (PHR) of infection with gastroenteritis (GI) and highly credible gastroenteritis (HCGI) illnesses from single exposure at several water abstraction points (WAPs) along the Njoro River in rural Kenya. Ambient geometric mean densities of Escherichia coli (EC) and intestinal enterococci (IE) were generally high (2-4 log units of cfu/100 ml) and risk levels were grossly in excess of acceptable health risk (AHR) levels for bathing and drinking. PHR was 2-3 times higher with the Cabelli (IE) model (Equation (2)) compared to the US EPA (EC) model (Equation (1)). Risk levels varied among WAPs in concomitance to the spatial and seasonal variability of ambient EC and IE densities. With the Cabelli IE model, PHR of HCGI illness on single exposure to the dry weather 95th percentile IE density for bathing was 2.5% of the exposed population at Logoman compared to 5.2% at Turkana Flats, 4.9% at Kenyatta or Nessuit and 4.6%, 4.5% and 4.2% at Treetop, Segotik and Njoro Bridge, respectively. PHR was ⩾5% on exposure to the wet weather 95th percentile IE density at all WAPs, excepting Treetop with 4.3%. Relative risk levels increased by at least 30 and 70 times for GI and HCGI illnesses, respectively, from drinking (250 ml) raw stream water, rising erratically in wet weather by >80% of the dry weather risk at Logoman, >30% at Njoro Bridge and Kenyatta and 10-15% at Segotik, Nessuit and Turkana Flats. By stipulating freshwater bathing water quality guidelines of 126 and 33 cfu/100 ml for EC and IE, respectively, US, EPA upholds maximum AHR levels at 0.7% and 1.9% for EC and IE, respectively. Hence, reducing current PHR levels at the WAPs to the US, EPA bathing AHR levels would require at least 2-4 log reductions of IE and EC densities with even further log reductions to achieve the WHO recommended drinking water AHR level of 0.1%. This would necessitate specialized treatment, in particular point-of-use treatment at the household level, as well as the implementation of comprehensive catchment management measures to protect the stream and the WAPs.
Enns, D K; Crandall, P G; O'Bryan, C A; Griffis, C L; Martin, E M
2007-05-01
Americans consume almost 40 kg per capita of chicken each year. Increasing consumption of chicken surpassed pork in 1982 and beef in 1992. The objectives of this study were to examine the effectiveness of a novel, 2-step cooking method of grilling, slicing, vacuum packaging, and hot water pasteurization to inhibit the growth of Listeria monocytogenes in chicken breast meat. Because this study required the use of pilot plant scale pasteurization equipment, Listeria innocua M1, a nonpathogen with slightly greater heat resistance than L. monocytogenes, was used as a surrogate. We first examined the lethal effects of grilling on a boneless skinless chicken breast to mimic cross-contaminated, surface-inoculated Listeria. Searing produced a mean reduction of 2.5 log CFU/g of Listeria and a moisture loss of only 7% (w/w). A 2nd experiment studied the lethal effect of pasteurization of the sliced seared chicken breast. L. innocua M1 inoculated between the slices mimicked contamination in deep muscle. Pasteurization in a 71 degrees C bath (final internal temperature of 66 degrees C) gave an additional 2.3 log CFU/g reduction. L. innocua M1 did not show significant regrowth during a wk of refrigerated storage. The combined 2-step cooking method of searing and pasteurization gave a combined 4.8 log reduction in LI M1. In parallel tests a non-Listeria indicator, Corynebacterium glutamicum, inoculated between sliced, seared chicken, showed a 3 log reduction after pasteurization for 10 min in a 71 degrees C bath compared to 2.3 log reduction of Listeria. Corynebacterium regrowth occurred much faster than did L. innocua M1.
The effect of anthropogenic activities to the decrease of water quality
NASA Astrophysics Data System (ADS)
Sidabutar, N. V.; Namara, I.; Hartono, D. M.; Soesilo, T. E. B.
2017-05-01
The raw water in Jakarta is supplied from Jatiluhur Dam, which is distributed pass through West Tarum Canal with an open canal about 70 km long. This water quality does not meet the standard set by the government and heavily polluted by anthropogenic activities along its river. This research uses a quantitative research approach with the mix-method. This research did an in-depth interview with inhabitants along the riverbank about their daily activity. The water along the riverbank is polluted by anthropogenic activities, such as: first: domestic activities (washing, cooking, and bathing), second: littering into the river, and third: discharging waste water from households into the river. This present research measures water quality for parameters pH, temperature, Dissolved Oxygen (DO), Chemical Oxygen Demand (COD), Total Dissolved Solid (TDS), Total Suspended Solid (TSS), and Fecal coliform. In this social segment, it is shown that pH, DO, TDS and Fecal coliformin the downstream part are worse than in the upstream.
Dicks, Kristen V; Lofgren, Eric; Lewis, Sarah S; Moehring, Rebekah W; Sexton, Daniel J; Anderson, Deverick J
2016-07-01
OBJECTIVE To determine whether daily chlorhexidine gluconate (CHG) bathing of intensive care unit (ICU) patients leads to a decrease in hospital-acquired infections (HAIs), particularly infections caused by methicillin-resistant Staphylococcus aureus (MRSA) and vancomycin-resistant Enterococcus (VRE). DESIGN Interrupted time series analysis. SETTING The study included 33 community hospitals participating in the Duke Infection Control Outreach Network from January 2008 through December 2013. PARTICIPANTS All ICU patients at study hospitals during the study period. METHODS Of the 33 hospitals, 17 hospitals implemented CHG bathing during the study period, and 16 hospitals that did not perform CHG bathing served as controls. Primary pre-specified outcomes included ICU central-line-associated bloodstream infections (CLABSIs), primary bloodstream infections (BSI), ventilator-associated pneumonia (VAP), and catheter-associated urinary tract infections (CAUTIs). MRSA and VRE HAIs were also evaluated. RESULTS Chlorhexidine gluconate (CHG) bathing was associated with a significant downward trend in incidence rates of ICU CLABSI (incidence rate ratio [IRR], 0.96; 95% confidence interval [CI], 0.93-0.99), ICU primary BSI (IRR, 0.96; 95% CI, 0.94-0.99), VRE CLABSIs (IRR, 0.97; 95% CI, 0.97-0.98), and all combined VRE infections (IRR, 0.96; 95% CI, 0.93-1.00). No significant trend in MRSA infection incidence rates was identified prior to or following the implementation of CHG bathing. CONCLUSIONS In this multicenter, real-world analysis of the impact of CHG bathing, hospitals that implemented CHG bathing attained a decrease in ICU CLABSIs, ICU primary BSIs, and VRE CLABSIs. CHG bathing did not affect rates of specific or overall infections due to MRSA. Our findings support daily CHG bathing of ICU patients. Infect Control Hosp Epidemiol 2016;37:791-797.
Stewart, Heather; Noakes, David L. G.; Cogliati, Karen M.; Peterson, James T.; Iversen, Martin H.; Schreck, Carl B.
2016-01-01
Studies on hydromineral balance in fishes frequently employ measurements of electrolytes following euthanasia. We tested the effects of fresh- or salt-water euthanasia baths of tricaine mesylate (MS-222) on plasma magnesium (Mg2+) and sodium (Na+) ions, cortisoland osmolality in fish exposed to saltwater challenges, and the ion and steroid hormone fluctuations over time following euthanasia in juvenile spring Chinook salmon (Oncorhynchus tshawytscha). Salinity of the euthanasia bath affected plasma Mg2+ and Na+concentrations as well as osmolality, with higher concentrations in fish euthanized in saltwater. Time spent in the bath positively affected plasma Mg2+ and osmolality, negatively affected cortisol, and had no effect on Na+ concentrations. The difference of temporal trends in plasma Mg2+ and Na+ suggests that Mg2+ may be more sensitive to physiological changes and responds more rapidly than Na+. When electrolytes and cortisol are measured as endpoints after euthanasia, care needs to be taken relative to time after death and the salinity of the euthanasia bath.
Stewart, Heather A; Noakes, David L G; Cogliati, Karen M; Peterson, James T; Iversen, Martin H; Schreck, Carl B
2016-02-01
Studies on hydromineral balance in fishes frequently employ measurements of electrolytes following euthanasia. We tested the effects of fresh- or salt-water euthanasia baths of tricaine mesylate (MS-222) on plasma magnesium (Mg(2+)) and sodium (Na(+)) ions, cortisol and osmolality in fish exposed to saltwater challenges, and the ion and steroid hormone fluctuations over time following euthanasia in juvenile spring Chinook salmon (Oncorhynchus tshawytscha). Salinity of the euthanasia bath affected plasma Mg(2+) and Na(+) concentrations as well as osmolality, with higher concentrations in fish euthanized in saltwater. Time spent in the bath positively affected plasma Mg(2+) and osmolality, negatively affected cortisol, and had no effect on Na(+) concentrations. The difference of temporal trends in plasma Mg(2+) and Na(+) suggests that Mg(2+) may be more sensitive to physiological changes and responds more rapidly than Na(+). When electrolytes and cortisol are measured as endpoints after euthanasia, care needs to be taken relative to time after death and the salinity of the euthanasia bath. Copyright © 2015 Elsevier Inc. All rights reserved.
Coated Metal Articles and Method of Making
Boller, Ernest R.; Eubank, Lowell D.
2004-07-06
The method of protectively coating metallic uranium which comprises dipping the metallic uranium in a molten alloy comprising about 20-75% of copper and about 80-25% of tin, dipping the coated uranium promptly into molten tin, withdrawing it from the molten tin and removing excess molten metal, thereupon dipping it into a molten metal bath comprising aluminum until it is coated with this metal, then promptly withdrawing it from the bath.
Pharyngeal cavity and the gills are the target organ for the repellent action of pardaxin in shark.
Primor, N
1985-05-15
Pardaxin, an active principle of the repellent secretion of the Red Sea flatfish, Pardachirus marmoratus, elicited severe struggling, mouth paralysis, and transient increase in urea leakage from the gills only when administered to the medium bathing the shark's pharyngeal cavity and gills. An apparatus was constructed which prevents a mixing of the outflow from shark's gills with water bathing its surface skin. It is concluded that in sharks the gills and/or the pharyngeal cavity are the target organ for the repellent action of pardaxin.
Hypothermic manipulation of bone cement can extend the handling time during vertebroplasty.
Lai, Po-Liang; Tai, Ching-Lung; Chu, I-Ming; Fu, Tsai-Sheng; Chen, Lih-Huei; Chen, Wen-Jer
2012-10-16
Polymethylmethacrylate (PMMA) is commonly used for clinical applications. However, the short handling time increases the probability of a surgeon missing the crucial period in which the cement maintains its ideal viscosity for a successful injection. The aim of this article was to illustrate the effects a reduction in temperature would have on the cement handling time during percutaneous vertebroplasty. The injectability of bone cement was assessed using a cement compressor. By twisting the compressor, the piston transmits its axial load to the plunger, which then pumps the bone cement out. The experiments were categorized based on the different types of hypothermic manipulation that were used. In group I (room temperature, sham group), the syringes were kept at 22°C after mixing the bone cement. In group 2 (precooling the bone cement and the container), the PMMA powder and liquid, as well as the beaker, spatula, and syringe, were stored in the refrigerator (4°C) overnight before mixing. In group 3 (ice bath cooling), the syringes were immediately submerged in ice water after mixing the bone cement at room temperature. The average liquid time, paste time, and handling time were 5.1 ± 0.7, 3.4 ± 0.3, and 8.5 ± 0.8 min, respectively, for group 1; 9.4 ± 1.1, 5.8 ± 0.5, and 15.2 ± 1.2 min, respectively, for group 2; and 83.8 ± 5.2, 28.8 ± 6.9, and 112.5 ± 11.3 min, respectively, for group 3. The liquid and paste times could be increased through different cooling methods. In addition, the liquid time (i.e. waiting time) for ice bath cooling was longer than for that of the precooling method (p < 0.05). Both precooling (i.e. lowering the initial temperature) and ice bath cooling (i.e. lowering the surrounding temperature) can effectively slow polymerization. Precooling is easy for clinical applications, while ice bath cooling might be more suitable for multiple-level vertebroplasty. Clinicians can take advantage of the improved injectability without any increased cost.
... hot water soaks (sitz baths). Seek immediate medical attention Have someone drive you to urgent care or ... of Privacy Practices Notice of Nondiscrimination Manage Cookies Advertising Mayo Clinic is a not-for-profit organization ...
Natural Radionuclide Activity Concentrations In Spas Of Argentina
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gnoni, G.; Czerniczyniec, M.; Canoba, A.
2008-08-07
Geothermal waters have been used on a large scale for bathing, drinking and medical purposes. These waters can contain natural radionuclides that may increase the exposure to people. In this work the most important natural radionuclide activity concentrations in different thermal spas of Argentina were measured to characterize waters and to evaluate the exposure of workers and members of the public.
Isolated core vs. superficial cooling effects on virtual maze navigation.
Payne, Jennifer; Cheung, Stephen S
2007-07-01
Cold impairs cognitive performance and is a common occurrence in many survival situations. Altered behavior patterns due to impaired navigation abilities in cold environments are potential problems in lost-person situations. We investigated the separate effects of low core temperature and superficial cooling on a spatially demanding virtual navigation task. There were 12 healthy men who were passively cooled via 15 degrees C water immersion to a core temperature of 36.0 degrees C, then transferred to a warm (40 degrees C) water bath to eliminate superficial shivering while completing a series of 20 virtual computer mazes. In a control condition, subjects rested in a thermoneutral (approximately 35 degrees C) bath for a time-matched period before being transferred to a warm bath for testing. Superficial cooling and distraction were achieved by whole-body immersion in 35 degree water for a time-matched period, followed by lower leg immersion in 10 degree C water for the duration of the navigational tests. Mean completion time and mean error scores for the mazes were not significantly different (p > 0.05) across the core cooling (16.59 +/- 11.54 s, 0.91 +/- 1.86 errors), control (15.40 +/- 8.85 s, 0.82 +/- 1.76 errors), and superficial cooling (15.19 +/- 7.80 s, 0.77 +/- 1.40 errors) conditions. Separately reducing core temperature or increasing cold sensation in the lower extremities did not influence performance on virtual computer mazes, suggesting that navigation is more resistive to cooling than other, simpler cognitive tasks. Further research is warranted to explore navigational ability at progressively lower core and skin temperatures, and in different populations.
Preparation of 99mTc-TRODAT-1 with high labeling yield in boiling water bath: a new formulation.
Erfani, Mostafa; Shafiei, Mohammad
2014-04-01
A new formulation for preparation of (99m)Tc-labeled tropane derivative, (99m)Tc-TRODAT-1, which is useful as a potential CNS dopamine transporter imaging agent, was evaluated and characterized. Preparation of (99m)Tc-TRODAT-1 was attained previously by a formulation in which vial has to be autoclaved at 121 °C for 30 min. It is highly desirable to further improve the preparation method by developing a simplified one vial formulation which will be labeled in boiling water bath (95 °C) for 15 min and a high labeling yield will be achieved. A formulation contained 10 μg of TRODAT-1, 20 μg tricine, 40 μg SnCl2 and 20mg manitol was prepared. Labeling was performed at 95 °C for 15 min and radiochemical analysis involved ITLC and HPLC methods. The stability of radioconjugate was checked in the presence of human serum at 37 °C up to 24h. (99m)Tc-TRODAT-1 was prepared with a radiochemical purity of more than 95% and specific activity of 64.3 MBq/nmol. Biodistribution studies of this new formulation in rats revealed similar regional brain distribution as compared with those obtained with the previous preparation in which brain uptake was high in striatum and striatum to cerebellum ratio was high. Requiring no autoclave facility for labeling, this new formulation will significantly improve the using feasibility of this radiopharmaceutical in clinic. Copyright © 2014 Elsevier Inc. All rights reserved.
Evaluation of analytical techniques to determine AQUI-S® 20E (eugenol) concentrations in water
Meinertz, Jeffery R.; Hess, Karina R.
2014-01-01
There is a critical need in U.S. public aquaculture and fishery management programs for an immediate-release sedative, i.e. a compound that can be safely and effectively used to sedate fish and subsequently, allow for their immediate release. AQUI-S® 20E (10% active ingredient, eugenol; any use of trade, firm, or product names is for descriptive purposes only and does not imply endorsement by the U.S. Government) is being pursued for U.S. approval as an immediate-release sedative. As part of the approval process, data describing animal safety and efficacy are needed. Essential to conducting studies that generate those data, is a method to accurately and precisely determine AQUI-S® 20E concentrations in exposure baths. Spectrophotometric and solid phase extraction (SPE)–high pressure liquid chromatography (LC) methods were developed and evaluated as methods to determine AQUI-S® 20E (eugenol) concentrations in water, methods that could be applied to any situation where eugenol was being evaluated as a fish sedative. The spectrophotometric method was accurate and precise (accuracy, > 87%; precision, 86%; precision < 8.9 %CV) when determining eugenol concentrations in solutions of 50 to 1000 mg/L AQUI-S® 20E made with LC grade water and water with varying pH and hardness. The SPE–LC method was influenced to a lesser degree by the presence of fish feed indicating greater specificity for eugenol.
Tributsch, Helmut
2016-01-01
Simple Summary The once widespread bearded vulture (Gypaetus barbatus) has the habit of bathing its polluted feathers and skin in red iron oxide-ochre-tainted water puddles. Primitive man may have tried to find out why: ochre is active in sunlight producing aggressive chemical species. They can kill viruses and bacteria and convert smelly organic substances into volatile neutral carbon dioxide gas. There is consequently a sanitary reason for the vulture’s habit of bathing in red ochre mud and this explains why prehistoric people included ochre use into their habits and rituals. Abstract Since primordial times, vultures have been competing with man for animal carcasses. One of these vultures, the once widespread bearded vulture (Gypaetus barbatus), has the habit of bathing its polluted feathers and skin in red iron oxide - ochre - tainted water puddles. Why? Primitive man may have tried to find out and may have discovered its advantages. Red ochre, which has accompanied human rituals and everyday life for more than 100,000 years, is not just a simple red paint for decoration or a symbol for blood. As modern experiments demonstrate, it is active in sunlight producing aggressive chemical species. They can kill viruses and bacteria and convert smelly organic substances into volatile neutral carbon dioxide gas. In this way, ochre can in sunlight sterilize and clean the skin to provide health and comfort and make it scentless, a definitive advantage for nomadic meat hunters. This research thus also demonstrates a sanitary reason for the vulture’s habit of bathing in red ochre mud. Prehistoric people have therefore included ochre use into their rituals, especially into those in relation to birth and death. Significant ritual impulses during evolution of man may thus have developed bio-mimetically, inspired from the habits of a vulture. It is discussed how this health strategy could be developed to a modern standard helping to fight antibiotics-resistant bacteria in hospitals. PMID:26784238
Hosseinzadeh, Reza; Khorsandi, Khatereh; Hemmaty, Syavash
2013-01-01
Micelle/water mixed solutions of different surface active agents were studied for their effectiveness in the extraction of polyphenolic compounds from various varieties of apples from west Azerbaijan province in Iran. The total content of polyphenolic compound in fruit extracts were determined using ferrous tartrate and Folin–Ciocalteu assays methods and chromatographic methods and compared with theme. High performance liquid chromatography is one of the most common and important methods in biochemical compound identification. The effect of pH, ionic strength, surfactant type, surfactant concentration, extraction time and common organic solvent in the apple polyphenolics extractions was studied using HPLC-DAD. Mixtures of surfactants, water and methanol at various ratios were examined and micellar-water solutions of Brij surfactant showed the highest polyphenol extraction efficiency. Optimum conditions for the extraction of polyphenolic compounds from apple occurred at 7 mM Brij35, pH 3. Effect of ionic strength on extraction was determined and 2% (W/V) potassium Chloride was determined to be the optimum salt concentration. The procedure worked well with an ultrasound bath. Total antioxidant capacity also was determined in this study. The method can be safely scaled up for pharmaceutical applications. PMID:23472082
Design of an experimental apparatus for measurement of the surface tension of metastable fluids
NASA Astrophysics Data System (ADS)
Vinš, V.; Hrubý, J.; Hykl, J.; Blaha, J.; Šmíd, B.
2013-04-01
A unique experimental apparatus for measurement of the surface tension of aqueous mixtures has been designed, manufactured, and tested in our laboratory. The novelty of the setup is that it allows measurement of surface tension by two different methods: a modified capillary elevation method in a long vertical capillary tube and a method inspired by the approach of Hacker (National Advisory Committee for Aeronautics, Technical Note 2510, 1-20, 1951), i.e. in a short horizontal capillary tube. Functionality of all main components of the apparatus, e.g., glass chamber with the capillary tube, temperature control unit consisting of two thermostatic baths with special valves for rapid temperature jumps, helium distribution setup allowing pressure variation above the liquid meniscus inside the capillary tube, has been successfully tested. Preliminary results for the surface tension of the stable and metastable supercooled water measured by the capillary elevation method at atmospheric pressure are provided. The surface tension of water measured at temperatures between +26 °C and -11 °C is in good agreement with the extrapolated IAPWS correlation (IAPWS Release on Surface Tension of Ordinary Water Substance, September 1994); however it disagrees with data by Hacker.
Peng, Yu-Min; Wang, Jih-Wen; Liue, Chun-Ying; Yeh, Shinn-Horng
1994-01-01
A method for preparing silicon carbide particles dispersed in an electrolytic bath for composite electroplating of metals includes the steps of washing the silicon carbide particles with an organic solvent; washing the silicon carbide particles with an inorganic acid; grinding the silicon carbide particles; and heating the silicon carbide particles in a nickel-containing solution at a boiling temperature for a predetermined period of time.
NASA Astrophysics Data System (ADS)
Chien, Heng-Chieh; Chu, En-Ting; Hsieh, Huey-Lin; Huang, Jing-Yi; Wu, Sheng-Tsai; Dai, Ming-Ji; Liu, Chun-Kai; Yao, Da-Jeng
2013-07-01
We devised a novel method to evaluate the temperature-dependent effective properties of a thermoelectric module (TEM): Seebeck coefficient ( S m), internal electrical resistance ( R m), and thermal conductance ( K m). After calculation, the effective properties of the module are converted to the average material properties of a p- n thermoelectric pillar pair inside the module: Seebeck coefficient ( S TE), electrical resistivity ( ρ TE), and thermal conductivity ( k TE). For a commercial thermoelectric module (Altec 1091) chosen to verify the novel method, the measured S TE has a maximum value at bath temperature of 110°C; ρ TE shows a positive linear trend dependent on the bath temperature, and k TE increases slightly with increasing bath temperature. The results show the method to have satisfactory measurement performance in terms of practicability and reliability; the data for tests near 23°C agree with published values.
Evaluation of analytical techniques to determine AQUI-S(R) 20E (eugenol) concentrations in water
Meinertz, Jeffery R.; Hess, Karina R.
2013-01-01
There is a critical need in U.S. public aquaculture and fishery management programs for an immediate-release sedative, i.e. a compound that can be safely and effectively used to sedate fish and subsequently, allow for their immediate release. AQUI-S® 20E (10% active ingredient, eugenol; any use of trade, firm, or product names is for descriptive purposes only and does not imply endorsement by the U.S. Government) is being pursued for U.S. approval as an immediate-release sedative. As part of the approval process, data describing animal safety and efficacy are needed. Essential to conducting studies that generate those data, is a method to accurately and precisely determine AQUI-S® 20E concentrations in exposure baths. Spectrophotometric and solid phase extraction (SPE)–high pressure liquid chromatography (LC) methods were developed and evaluated as methods to determine AQUI-S® 20E (eugenol) concentrations in water, methods that could be applied to any situation where eugenol was being evaluated as a fish sedative. The spectrophotometric method was accurate and precise (accuracy, > 87%; precision, < 0.70 %CV) when determining eugenol concentrations in solutions of 50 to 1000 mg/L AQUI-S® 20E made with LC grade water and water with varying pH and hardness. The spectrophotometric method's accuracy was negatively affected when analyzing water containing fish feed. The SPE–LC method was also accurate and precise (accuracy > 86%; precision < 8.9 %CV) when determining eugenol concentrations in solutions of 50 to 1000 mg/L AQUI-S® 20E made with LC grade water and water with varying pH and hardness. The SPE–LC method was influenced to a lesser degree by the presence of fish feed indicating greater specificity for eugenol.
Ogai, K; Matsumoto, M; Aoki, M; Ota, R; Hashimoto, K; Wada, R; Kobayashi, M; Sugama, J
2017-11-01
Presently, skin-cleaning agents that claim to be removed by water or wiping alone are commercially available and have been used for the purpose of bed baths. However, there is a lack of knowledge on how water washing and wiping differently affect skin physiological functions or ceramide content. The aim of this study was to compare the effects of water washing and wiping on skin physiological functions and ceramide content. Three kinds of the cleaning agents with different removal techniques (ie, water washing and wiping) were used in this study. Skin physiological functions (ie, transepidermal water loss, skin hydration, and skin pH) and skin ceramide content were measured before and after seven consecutive days of the application of each cleaning agent. No significant differences in skin physiological functions or ceramide content were observed between water washing and wiping. Cleaning agents that claim to be removed by water washing or wiping do not affect skin physiological functions or ceramide content by either removal method. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Possibility of heat recovery from gray water in residential building
NASA Astrophysics Data System (ADS)
Mazur, Aleksandra; Słyś, Daniel
2017-12-01
Recovery of waste heat from gray water can be an interesting alternative to other energy saving systems in a building, including alternative energy sources. Mainly, due to a number of advantages including independence from weather conditions, small investment outlay, lack of user support, or a slight interference with the installation system. The purpose of this article is to present the financial effectiveness of installations which provide hot, usable water to a detached house, using a Drain Water Heat Recovery (DWHR) system depending on the number of system users and the various combinations of bathing time in the shower, which has an influence on the daily warm water demand in each of the considered options. The economic analysis of the adopted installation variants is based on the Life Cycle Cost (LCC) method, which is characterized by the fact that it also includes the operating costs in addition to the capital expenditure during the entire analysis period. For each case, the necessary devices were selected and the cost of their installation was estimated.
Validity, Reliability, and Inertia of Four Different Temperature Capsule Systems.
Bongers, Coen C W G; Daanen, Hein A M; Bogerd, Cornelis P; Hopman, Maria T E; Eijsvogels, Thijs M H
2018-01-01
Telemetric temperature capsule systems are wireless, relatively noninvasive, and easily applicable in field conditions and have therefore great advantages for monitoring core body temperature. However, the accuracy and responsiveness of available capsule systems have not been compared previously. Therefore, the aim of this study was to examine the validity, reliability, and inertia characteristics of four ingestible temperature capsule systems (i.e., CorTemp, e-Celsius, myTemp, and VitalSense). Ten temperature capsules were examined for each system in a temperature-controlled water bath during three trials. The water bath temperature gradually increased from 33°C to 44°C in trials 1 and 2 to assess the validity and reliability, and from 36°C to 42°C in trial 3 to assess the inertia characteristics of the temperature capsules. A systematic difference between capsule and water bath temperature was found for CorTemp (0.077°C ± 0.040°C), e-Celsius (-0.081°C ± 0.055°C), myTemp (-0.003°C ± 0.006°C), and VitalSense (-0.017°C ± 0.023°C; P < 0.010), with the lowest bias for the myTemp system (P < 0.001). A systematic difference was found between trial 1 and trial 2 for CorTemp (0.017°C ± 0.083°C; P = 0.030) and e-Celsius (-0.007°C ± 0.033°C; P = 0.019), whereas temperature values of myTemp (0.001°C ± 0.008°C) and VitalSense (0.002°C ± 0.014°C) did not differ (P > 0.05). Comparable inertia characteristics were found for CorTemp (25 ± 4 s), e-Celsius (21 ± 13 s), and myTemp (19 ± 2 s), whereas the VitalSense system responded more slowly (39 ± 6 s) to changes in water bath temperature (P < 0.001). Although differences in temperature and inertia were observed between capsule systems, an excellent validity, test-retest reliability, and inertia was found for each system between 36°C and 44°C after removal of outliers.
Han, Quan; Huo, Yanyan; Wu, Jiangyan; He, Yaping; Yang, Xiaohui; Yang, Longhu
2017-03-24
A highly sensitive method based on cloud point extraction (CPE) separation/preconcentration and graphite furnace atomic absorption spectrometry (GFAAS) detection has been developed for the determination of ultra-trace amounts of rhodium in water samples. A new reagent, 2-(5-iodo-2-pyridylazo)-5-dimethylaminoaniline (5-I-PADMA), was used as the chelating agent and the nonionic surfactant TritonX-114 was chosen as extractant. In a HAc-NaAc buffer solution at pH 5.5, Rh(III) reacts with 5-I-PADMA to form a stable chelate by heating in a boiling water bath for 10 min. Subsequently, the chelate is extracted into the surfactant phase and separated from bulk water. The factors affecting CPE were investigated. Under the optimized conditions, the calibration graph was linear in the range of 0.1-6.0 ng/mL, the detection limit was 0.023 ng/mL for rhodium and relative standard deviation was 3.67% ( c = 1.0 ng/mL, n = 11).The method has been applied to the determination of trace rhodium in water samples with satisfactory results.
[History of hot spring bath treatment in China].
Hao, Wanpeng; Wang, Xiaojun; Xiang, Yinghong; Gu Li, A Man; Li, Ming; Zhang, Xin
2011-07-01
As early as the 7th century B.C. (Western Zhou Dynasty), there is a recording as 'spring which contains sulfur could treat disease' on the Wentang Stele written by WANG Bao. Wenquan Fu written by ZHANG Heng in the Easten Han Dynasty also mentioned hot spring bath treatment. The distribution of hot springs in China has been summarized by LI Daoyuan in the Northern Wei Dynasty in his Shuijingzhu which recorded hot springs in 41 places and interpreted the definition of hot spring. Bencao Shiyi (by CHEN Cangqi, Tang Dynasty) discussed the formation of and indications for hot springs. HU Zai in the Song Dynasty pointed out distinguishing hot springs according to water quality in his book Yuyin Conghua. TANG Shenwei in the Song Dynasty noted in Jingshi Zhenglei Beiji Bencao that hot spring bath treatment should be combined with diet. Shiwu Bencao (Ming Dynasty) classified hot springs into sulfur springs, arsenicum springs, cinnabar springs, aluminite springs, etc. and pointed out their individual indications. Geologists did not start the work on distribution and water quality analysis of hot springs until the first half of the 20th century. There are 972 hot springs in Wenquan Jiyao (written by geologist ZHANG Hongzhao and published in 1956). In July 1982, the First National Geothermal Conference was held and it reported that there were more than 2600 hot springs in China. Since the second half of the 20th century, hot spring sanatoriums and rehabilitation centers have been established, which promoted the development of hot spring bath treatment.
Yamini, Yadollah; Saleh, Abolfazl
2013-07-01
An efficient method based on ultrasound-assisted emulsification microextraction followed by injection-port derivatization GC analysis was developed to determine 2,4-dichlorophenoxyacetic acid (2,4-D) and 4-chloro-2-methylphenoxyacetic acid (MCPA) in natural water samples. In this procedure, 12.5 μL of 1-undecanol was injected slowly into a 12 mL home-designed centrifuge glass vial containing an aqueous sample of the analytes located inside an ultrasonic water bath. The resulting emulsion was centrifuged, and 1 μL of the separated organic solvent together with 1 μL of the derivatization reagent were injected into a GC equipped with a flame ionization detector. Several factors that influence the derivatization and extraction were optimized. Under the optimal conditions, the LODs were 0.33 and 1.7 μg/L for MCPA and 2,4-D, respectively. Preconcentration factors of 670 and 836 were obtained for MCPA and 2,4-D, respectively. The precision of the proposed method was evaluated in terms of repeatability, which was <5.7% (n = 5). The applicability of the proposed method was evaluated by extraction and determination of chlorophenoxyacetic acids from some natural waters, which indicated that the matrices of natural waters have no significant effect on the extraction and derivatization efficiency of this method. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Freitas, Patrícia de; Marques, Silvia Rezende; Alves, Taisy Bezerra; Takahashi, Juliana; Kimura, Amélia Fumiko
2014-08-01
Objective To verify the effect of bathing on the body temperature of preterm infants (PTI). Method Systematic review conducted in the following bibliographic electronic sources: Biblioteca Virtual em Saúde/Lilacs (BVS), Cumulated Index of Nursing and Allied Health Literature (CINAHL), Cochrane Library, Google Scholar, PubMed, SCOPUS and Web of Science, using a combination of search terms, keywords and free terms. The review question was adjusted to the PICO acronym (Patient/population, Intervention, Control/comparative intervention, Outcome). The selected publications were evaluated according to levels of evidence and grades of recommendation for efficacy/effectiveness studies, as established by the Joanna Briggs Institute. Results Eight hundred and twenty four (824) publications were identified and four studies met the inclusion criteria, of which three analyzed the effect of sponge baths and the effect of immersion baths. Conclusion Sponge baths showed a statistically significant drop in body temperature, while in immersion baths the body temperature remained stable, although they studied late preterm infants.
Risk factors for seabather's eruption: a prospective cohort study.
Kumar, S; Hlady, W G; Malecki, J M
1997-01-01
OBJECTIVE: A prospective cohort study was performed to identify risk factors for seabather's eruption. METHODS: Study participants were recruited at four beaches in Palm Beach County, Florida, during three weekends of May and June 1993. Participants were interviewed by telephone after 48 hours regarding medical history, beach activities, development of rashes, and use of possible preventive measures. RESULTS: Seabather's eruption, defined by the occurrence of a rash within two days of exposure to seawater, was reported by 114 (16%) of 735 respondents. The strongest predictor of seabather's eruption was a past history of the condition. Children less than 16 years of age were also at increased risk, as were surfers. Showering with one's bathing suit off was a useful protective measure. CONCLUSION: The study's findings suggest that when the seasonal risk of seabather's eruption is present, children, people with a history of seabather's eruption, and surfers are at greatest risk. During the sea lice season, seabathers can minimize their risk by showering with their bathing suits off after seabathing. Length of the time spent in water was not significantly associated with seabather's eruption. PMID:9018290
Nikolopoulos, Dimitrios; Vogiannis, Efstratios; Petraki, Ermioni; Zisos, Athanasios; Louizi, Anna
2010-01-01
Radon and progeny ((218)Po, (214)Pb, (214)Bi and (214)Po) in thermal spas are well known radioactive pollutants identified for additional radiation burden of patients due to the activity concentration peaks which appear during bath treatment or due to drinking of waters of high radon content. This burden affects additionally the working personnel of the spas. The present paper has focused on the thermal spas of Loutraki (Attica-Greece). The aim was the investigation of the health impact for patients and working personnel due to radon and progeny. Attention has been paid to radon and progeny transient concentration peaks (for bath treatment) and to radon of thermal waters (both for bath treatment and drinking therapy). Designed experiments have been carried out, which included radon and progeny activity concentration measurements in thermal waters and ambient air. Additionally, published models for description of radon and progeny transient concentration peaks were employed. The models were based on physicochemical processes involved and employed non linear first order derivative mass balance differential equations which were solved numerically with the aid of specially developed computer codes. The collected measurements were analysed incorporating these models. Results were checked via non linear statistical tests. Predictions and measurements were found in close agreement. Non linear parameters were estimated. The models were employed for dosimetric estimations of patients and working personnel. The effective doses of patients receiving bath treatment were found low but not negligible. The corresponding doses to patients receiving potable treatment were found high but below the proposed international limits. It was found that the working personnel are exposed to considerable effective doses, however well below the acceptable limits for workers. It was concluded that treatment and working in the Loutraki spas leads to intense variations of radon and progeny and consequently additional health impact both to patients and working personnel.
NASA Astrophysics Data System (ADS)
Yanai, T.; Koda, K.; Eguchi, K.; Morimura, T.; Takashima, K.; Nakano, M.; Fukunaga, H.
2018-04-01
We have already reported Fe-Ni films with good soft magnetic properties prepared by using an electroplating method. In the present study, we employed an annealing for further improvement in soft magnetic properties of the electroplated Fe-Ni films. The annealing reduces the coercivity of the films, and the reduction rate of the coercivity depended on the Cl- ion concentration in the bath. The Fe22Ni78 films prepared in the plating bath with high Cl- ion concentration showed large reduction rate of the coercivity, and we found that the annealing is more effective for high Cl- ion concentration bath since much lower coercivity value can be obtained compared with that for low Cl- ion concentration one.
Development of Abnormality Detection System for Bathers using Ultrasonic Sensors
NASA Astrophysics Data System (ADS)
Ohnishi, Yosuke; Abe, Takehiko; Nambo, Hidetaka; Kimura, Haruhiko; Ogoshi, Yasuhiro
This paper proposes an abnormality detection system for bather sitting in bathtub. Increasing number of in-bathtub drowning accidents in Japan draws attention. Behind this large number of bathing accidents, Japan's unique social and cultural background come surface. For majority of people in Japan, bathing serves purpose in deep warming up of body, relax and enjoyable time. Therefore it is the custom for the Japanese to soak in bathtub. However overexposure to hot water may cause dizziness or fainting, which is possible to cause in-bathtub drowning. For drowning prevention, the system detects bather's abnormal state using an ultrasonic sensor array. The array, which has many ultrasonic sensors, is installed on the ceiling of bathroom above bathtub. The abnormality detection system uses the following two methods: posture detection and behavior detection. The function of posture detection is to estimate the risk of drowning by monitoring bather's posture. Meanwhile, the function of behavior detection is to estimate the risk of drowning by monitoring bather's behavior. By using these methods, the system detects bathers' different state from normal. As a result of experiment with a subject in the bathtub, the system was possible to detect abnormal state using subject's posture and behavior. Therefore the system is useful for monitoring bather to prevent drowning in bathtub.
Acoustic and thermal properties of tissue
NASA Astrophysics Data System (ADS)
Retat, L.; Rivens, I.; ter Haar, G. R.
2012-10-01
Differences in ultrasound (US) and thermal properties of abdominal soft tissues may affect the delivery of thermal therapies such as high intensity focused ultrasound and may provide a basis for US monitoring of such therapies. 21 rat livers were obtained, within one hour of surgical removal. For a single liver, 3 lobes were selected and each treated in one of 3 ways: maintained at room temperature, water bath heated to 50°C ± 1°C for 10 ± 0.5 minutes, or water bath heated to 60°C ± 1°C for 10 ± 0.6 minutes. The attenuation coefficient, speed of sound and thermal conductivity of fresh rat liver was measured. The attenuation coefficients and speed of sound were measured using the finite-amplitude insertion-substitution (FAIS) method. For each rat liver, the control and treated lobes were scanned using a pair of weakly focused 2.5 MHz Imasonic transducers over the range 1.8 to 3 MHz. The conductivity measurement apparatus was designed to provide one-dimensional heat flow through each specimen using a combination of insulation, heat source and heat sink. Using 35 MHz US images to determine the volume of air trapped in the system, the thermal conductivity was corrected using a simulation based on the Helmhotz bio-heat equation. The process of correlating these results with biological properties is discussed.
U.S. EPA guidance on the safety of surface waters for recreational use is currently based on epidemiological studies conducted in the 1980?s that demonstrated a strong positive correlation between bathing-associated illness rates and concentrations of culturable fecal indicator b...
46 CFR 110.15-1 - Definitions.
Code of Federal Regulations, 2014 CFR
2014-10-01
... salt water or a location on board which may be exposed to the corrosive effects of the cargo carried or... of the Coast Guard. Corrosion resistant material or finish means any material or finish that meets... store room; (3) A passageway adjacent to quarters; (4) A water closet without a shower or bath; (5) A...
46 CFR 110.15-1 - Definitions.
Code of Federal Regulations, 2013 CFR
2013-10-01
... salt water or a location on board which may be exposed to the corrosive effects of the cargo carried or... of the Coast Guard. Corrosion resistant material or finish means any material or finish that meets...) A dry store room; (3) A passageway adjacent to quarters; (4) A water closet without a shower or bath...
Rotation of melting ice disks due to melt fluid flow.
Dorbolo, S; Adami, N; Dubois, C; Caps, H; Vandewalle, N; Darbois-Texier, B
2016-03-01
We report experiments concerning the melting of ice disks (85 mm in diameter and 14 mm in height) at the surface of a thermalized water bath. During the melting, the ice disks undergo translational and rotational motions. In particular, the disks rotate. The rotation speed has been found to increase with the bath temperature. We investigated the flow under the bottom face of the ice disks by a particle image velocimetry technique. We find that the flow goes downwards and also rotates horizontally, so that a vertical vortex is generated under the ice disk. The proposed mechanism is the following. In the vicinity of the bottom face of the disk, the water eventually reaches the temperature of 4 °C for which the water density is maximum. The 4 °C water sinks and generates a downwards plume. The observed vertical vorticity results from the flow in the plume. Finally, by viscous entrainment, the horizontal rotation of the flow induces the solid rotation of the ice block. This mechanism seems generic: any vertical flow that generates a vortex will induce the rotation of a floating object.
Bailey, Rachel R.; Stuckey, Dianna R.; Norman, Bryan A.; Duggan, Andrew P.; Bacon, Kristina M.; Connor, Diana L.; Lee, Ingi; Muder, Robert R.; Lee, Bruce Y.
2012-01-01
OBJECTIVE To estimate the economic value of dispensing preoperative home-based chlorhexidine bathing cloth kits to orthopedic patients to prevent surgical site infection (SSI). METHODS A stochastic decision-analytic computer simulation model was developed from the hospital’s perspective depicting the decision of whether to dispense the kits preoperatively to orthopedic patients. We varied patient age, cloth cost, SSI-attributable excess length of stay, cost per bed-day, patient compliance with the regimen, and cloth antimicrobial efficacy to determine which variables were the most significant drivers of the model’s outcomes. RESULTS When all other variables remained at baseline and cloth efficacy was at least 50%, patient compliance only had to be half of baseline (baseline mean, 15.3%; range, 8.23%–20.0%) for chlorhexidine cloths to remain the dominant strategy (ie, less costly and providing better health outcomes). When cloth efficacy fell to 10%, 1.5 times the baseline bathing compliance also afforded dominance of the preoperative bath. CONCLUSIONS The results of our study favor the routine distribution of bathing kits. Even with low patient compliance and cloth efficacy values, distribution of bathing kits is an economically beneficial strategy for the prevention of SSI. PMID:21515977
Garnov, I O; Kuchin, A V; Loginova, T P; Varlamova, N G; Boiko, E R
2016-01-01
The baths with emulsified turpentine find the wide application in balneotherapy. They produce especially pronounced beneficial prophylactic effects in the patients presenting with microtrombosis and microvascular stasis. Moreover, these baths may be prescribed to improve microcirculation, increase the functional reserves and physical capacity in the athletes. At the same time, the current literature appears to contain no scientific publications on the application of emulsified turpentine baths for the restoration of the physical capacity of the professional ski runners. The lack of relevant information motivated the study reported in the present article. The main objective of the study involving 10 subjects was to evaluate the effectiveness of the modified emulsified turpentine baths as a method by which to restore and enhance the physical capacity of the professional cross-country skiers. The physical capacity of the athletes was evaluated from the results of the bicycle ergometer exercise test with the use of the «Oxycon Pro» system. The data obtained suggest that a course of the emulsified turpentine baths increases the activity of the cardiorespiratory system, improves the physical capacity, and enhances the functional reserves of the body in the anaerobic zone.
Isotopic effects in vibrational relaxation dynamics of H on a Si(100) surface
NASA Astrophysics Data System (ADS)
Bouakline, F.; Lorenz, U.; Melani, G.; Paramonov, G. K.; Saalfrank, P.
2017-10-01
In a recent paper [U. Lorenz and P. Saalfrank, Chem. Phys. 482, 69 (2017)], we proposed a robust scheme to set up a system-bath model Hamiltonian, describing the coupling of adsorbate vibrations (system) to surface phonons (bath), from first principles. The method is based on an embedded cluster approach, using orthogonal coordinates for system and bath modes, and an anharmonic phononic expansion of the system-bath interaction up to second order. In this contribution, we use this model Hamiltonian to calculate vibrational relaxation rates of H-Si and D-Si bending modes, coupled to a fully H(D)-covered Si(100)-( 2 × 1 ) surface, at zero temperature. The D-Si bending mode has an anharmonic frequency lying inside the bath frequency spectrum, whereas the H-Si bending mode frequency is outside the bath Debye band. Therefore, in the present calculations, we only take into account one-phonon system-bath couplings for the D-Si system and both one- and two-phonon interaction terms in the case of H-Si. The computation of vibrational lifetimes is performed with two different approaches, namely, Fermi's golden rule, and a generalized Bixon-Jortner model built in a restricted vibrational space of the adsorbate-surface zeroth-order Hamiltonian. For D-Si, the Bixon-Jortner Hamiltonian can be solved by exact diagonalization, serving as a benchmark, whereas for H-Si, an iterative scheme based on the recursive residue generation method is applied, with excellent convergence properties. We found that the lifetimes obtained with perturbation theory, albeit having almost the same order of magnitude—a few hundred fs for D-Si and a couple of ps for H-Si—, are strongly dependent on the discretized numerical representation of the bath spectral density. On the other hand, the Bixon-Jortner model is free of such numerical deficiencies, therefore providing better estimates of vibrational relaxation rates, at a very low computational cost. The results obtained with this model clearly show a net exponential decay of the time-dependent survival probability for the H-Si initial vibrational state, allowing an easy extraction of the bending mode "lifetime." This is in contrast with the D-Si system, whose survival probability exhibits a non-monotonic decay, making it difficult to define such a lifetime. This different behavior of the vibrational decay is rationalized in terms of the power spectrum of the adsorbate-surface system. In the case of D-Si, it consists of several, non-uniformly distributed peaks around the bending mode frequency, whereas the H-Si spectrum exhibits a single Lorentzian lineshape, whose width corresponds to the calculated lifetime. The present work gives some insight into mechanisms of vibration-phonon coupling at surfaces. It also serves as a benchmark for multidimensional system-bath quantum dynamics, for comparison with approximate schemes such as reduced, open-system density matrix theory (where the bath is traced out and a Liouville-von Neumann equation is solved) or approximate wavefunction methods to solve the combined system-bath Schrödinger equation.
Laser Initiated Ignition of Liquid Propellant
1991-01-31
containers held in a water bath of constant temperature 70*C. A larger vessel containing approximately 2ml of propellant was also heated in each experiment and...controller. A stirrer and forced water circulation ensured that all samples were kept at the same temperature. The water wai first heated to the final 5... electrolysed samples. 3 .. .. ....... ......................... volume of 10 ....... . 5 ....... I • . ... .. . .... .. ...... .. . . .. . . ... . .61.8 2 22i
Cooling of Water in a Flask: Convection Currents in a Fluid with a Density Maximum
ERIC Educational Resources Information Center
Velasco, S.; White, J. A.; Roman, F. L.
2010-01-01
The effect of density inversion on the convective flow of water in a spherical glass flask cooled with the help of an ice-water bath is shown. The experiment was carried out by temperature measurements (cooling curves) taken at three different heights along the vertical diameter of the flask. Flows inside the flask are visualized by seeding the…
NASA Astrophysics Data System (ADS)
Eskandari, Alireza; Abdizadeh, Hossein; Pourshaban, Erfan; Golobostanfard, Mohammad Reza
2018-01-01
Zinc oxide nanowires are considered as promising materials for wide range of optoelectrical and chemical devices, thanks to their desirable structural and optoelectrical properties. Over the past decade, chemical bath deposition (CBD) has been widely used to synthesize these nanostructures due to its low cost and controllability. Since improving the aspect ratio and length of nanowires is a vital issue in growing one-dimensional nanostructures, the influence of polyethyleneimine (PEI) as a complexing and chelating agent on the structural, morphological, and optoelectrical properties of ZnO nanowires has been studied in this report. As-grown ZnO nanowires synthesized by mixing deionized water, zinc acetate dihydrate, hexamethylenetetramine, and PEI were characterized with field emission scanning electron microscope (FESEM), X-ray diffractometer (XRD), and photoluminescence spectroscopy (PL). FESEM results unambiguously show that increasing PEI concentration (from 0 to 0.2 g in 50 ml DI water) reduces the diameter and density of nanowires from ˜120 to 56 nm and from ˜85% to 65%, respectively. Interestingly, although adding more PEI decreases nanowires diameter, over-increasing of PEI brings about an inappropriate nanostructures growth. Moreover, XRD patterns demonstrate that all the samples have wurtzite structure with a preferred orientation along c-axis which may be improved or deteriorated by adding PEI into the chemical bath. Accordingly, it is crucial to optimize the amount of PEI in CBD method. Near-band edge (NBE) region in PL spectrum also confirms wide bandgap of ZnO (˜3.3 eV). In addition, comparing the appearance of PEI free with PEI assisted solutions show a considerable difference in their colors, which may be attributed to the formation of new chemical compounds. Considering these results, PEI plays a couple of determining roles in synthesizing ZnO nanowires; making nanowires thinner, with selectively absorption to the non-polar, lateral facets of wurtzite lattice, and controlling deposition rate by forming the PEI-Zn2+-HCHO complex compounds.
NASA Technical Reports Server (NTRS)
Boehm, G.; Ekert, FR.
1988-01-01
According to current information, baths have a four-fold effect on the circulation: (1) Dilation or constriction is produced in the area of the blood vessels in the skin as a result of thermal, chemical or mechanical stimuli; (2) This reaction in the dermal vascular system produces a further effect on the central vessels in the extremities, the area of the splanchnicus, and other body cavities; (3) The reflect transposition of other organ systems, i.e., the respiratory organs, has a reaction on the circulation; and (4) The water pressure of the bath has a hydrostatic effect, i.e., on the one hand it empties peripheral veins more rapidly, and on the other it increases the intra-abdominal pressure and this reduces once again the circulation in the area of the splanchnicus.
2015-01-01
Spider silk has exceptional mechanical and biocompatibility properties. The goal of this study was optimization of the mechanical properties of synthetic spider silk thin films made from synthetic forms of MaSp1 and MaSp2, which compose the dragline silk of Nephila clavipes. We increased the mechanical stress of MaSp1 and 2 films solubilized in both HFIP and water by adding glutaraldehyde and then stretching them in an alcohol based stretch bath. This resulted in stresses as high as 206 MPa and elongations up to 35%, which is 4× higher than the as-poured controls. Films were analyzed using NMR, XRD, and Raman, which showed that the secondary structure after solubilization and film formation in as-poured films is mainly a helical conformation. After the post-pour stretch in a methanol/water bath, the MaSp proteins in both the HFIP and water-based films formed aligned β-sheets similar to those in spider silk fibers. PMID:25030809
Gan, Hongjian; He, Haiwen; Sato, Atsushi; Hatta, Hajime; Nakao, Miki; Somamoto, Tomonori
2015-04-01
Ulcer disease, caused by atypical Aeromonas salmonicida, is a serious concern in ornamental koi carp, because it induces skin ulceration, disfiguring ornamental fish and causing economic loses. The present study aimed to establish a novel prophylaxis with chicken egg yolk immunoglobulin, IgY, against ulcer disease and to assess its feasibility in the ornamental fish industry. Addition of egg yolk powder containing anti-A. salmonicida IgY to rearing water provided significant protection against an A. salmonicida bath infection, whereas administration of non-specific IgY did not. Consecutive immersion of fish into rearing water containing specific IgY completely prevented ulcer disease resulting from cohabitation infection, indicating that this prophylaxis could prevent infection from such type of contact. Thus, passive immunization induced by immersing fish into aquarium water containing specific IgY is a prospective prophylaxis against diseases caused by pathogens that invade the skin and gills. Copyright © 2015 Elsevier Ltd. All rights reserved.
An unusual pattern of decomposition associated with suicidal electrocution in a bath.
Fernando, Tarini; Winskog, Calle; Byard, Roger W
2013-07-01
A 51-year-old man was found dead face down and partially submerged in a bathtub alongside two hairdryers. The hairdryers had continued to work, as the victim had bypassed the electrical board of the house prior to dropping them into the water. This had resulted in death due to electrocution, with subsequent heating of the bath water causing marked putrefaction and softening of the immersed body parts. The back and feet, which were not submerged, were preserved. The degree of anterior decomposition was not in keeping with the postmortem interval; however, regional decomposition with sparing of the back and feet provided a clue at autopsy as to the sequence of events. Individuals with training in, or knowledge of, electrical circuitry are capable of modifying domestic wiring so that safety switches and/or fuses can be bypassed ensuring that electrical devices will continue to function even while under water. © 2013 American Academy of Forensic Sciences.
NASA Astrophysics Data System (ADS)
Ventorino, V.; Pepe, O.; Sannino, L.; Blaiotta, G.; Palomba, S.
2012-04-01
Built between the walls of Herculaneum excavations, one of the world's most important archaeological sites, and the sea in the early 1st cent. AD, the Suburban Bath is one of the best thermal complexes better preserved in ancient times. The entrance opens onto a large courtyard that leads into a hallway well lit by a skylight, impluvium, with a portrait of "Apollo". From this room you can access various parts of the thermae, all beautifully preserved. A single room, mostly occupied by the pool, serving both apodyterium (dressing room) that frigidarium. Among tepidarium and frigidarium there's a room elegantly decorated with stucco and marble. The vestibule opens to the right, through a corridor, onto a waiting room with a floor in signinum opus and into a praefurnium (oven for heating). A large pool of tepidarium, connected with laconicum, a small circular room for the baths sweat, is also present. The calidarium, as usual, has a small tank for hot water and a basin for washing in cold water. Behind the calidarium is the praefurnium, an environment with the boiler for heating the bath. Although the suburban baths are well preserved, unfortunately in you can observe the development of visible microbial coatings. During the biodeterioration process, secondary colonization of wall is due to heterotrophic bacteria and fungi that induce deterioration cause structural as well as aesthetic damage such as the discoloration of materials, the formation of crusts on surfaces and the loss of material. This investigation was carried out sampling the surfaces of walls of different rooms in the Suburban Thermae according to Italian legal procedures. Depending on the samples typology, sampling was carry out using sterile nitrocellulose membranes pressed on the surface of the walls, sterile swabs or with sterile tweezers by tearing out surface material. The samples were suspended in physiological solution and immediately refrigerated until analysis. Isolated colonies grown on PCA plates were purified in the same growth medium by streaking and differentiated by assessing their morphological (phase-contrast microscopy) and biochemical characteristics (Gram-stains KOH-lysis and catalase activity). Cultural-based method allow us to identify by 16S and 26S rRNA partial sequence analysis, heterotrophic bacteria belonging to different genera as Bacillus, Pseudomonas, Aeromonas and Microbacterium. By using this approach, Bacillus-related species (B. benzoevorans, B. megaterium and B. pumilis and B. megaterium/B. simplex group) as well as Aeromonas sobria/Aeromonas salmonicida/Aeromonas hydrophila group, Pseudomonas plecoglossicida and Microbacterium esteraromaticum were isolated in different sample points analysed. DGGE analysis of PCR amplified V3 region of rDNA from DNA directly recovered from samples of biofilms and patina, enabled identification of bacterial species not found using culturable technology, as those closest related to Aeromonas, Paenibacillus, Brevibacterium, Exiguobacterium, Microbacterium, Brevibacterium, Stenothophomonas and Streptomyces. Combination of culture-dependent and independent methods provide a better characterization of heterotrophic microbiota that colonize the surface of ancient decorated walls and can contribute to understand the potential of biodeterioration activity by heterotrophic microorganisms.
NASA Astrophysics Data System (ADS)
Sengupta, Srijan; Patra, Arghya; Jena, Sambedan; Das, Karabi; Das, Siddhartha
2018-03-01
In this study, the electrodeposition of nickel foam by dynamic hydrogen bubble-template method is optimized, and the effects of key deposition parameters (applied voltage and deposition time) and bath composition (concentration of Ni2+, pH of the bath, and roles of Cl- and SO4 2- ions) on pore size, distribution, and morphology and crystal structure are studied. Nickel deposit from 0.1 M NiCl2 bath concentration is able to produce the honeycomb-like structure with regular-sized holes. Honeycomb-like structure with cauliflower morphology is deposited at higher applied voltages of 7, 8, and 9 V; and a critical time (>3 minutes) is required for the development of the foamy structure. Compressive residual stresses are developed in the porous electrodeposits after 30 seconds of deposition time (-189.0 MPa), and the nature of the residual stress remains compressive upto 10 minutes of deposition time (-1098.6 MPa). Effect of pH is more pronounced in a chloride bath compared with a sulfate bath. The increasing nature of pore size in nickel electrodeposits plated from a chloride bath (varying from 21 to 48 μm), and the constant pore size (in the range of 22 to 24 μm) in deposits plated from a sulfate bath, can be ascribed to the striking difference in the magnitude of the corresponding current-time profiles.
Cholinergic urticaria with anaphylaxis: hazardous duty of a deployed US marine.
Handfield, Kent S; Dolan, Christopher K; Kaplan, Michael
2015-04-01
Cholinergic urticaria (CU) is triggered by a rise in body temperature and can be complicated by bronchial hyperresponsiveness and anaphylaxis. It primarily affects young adults who actively engage in strenuous exercise, such as servicemen and servicewomen. If the patient reports a history of wheezing or difficulty breathing with urticaria, a water challenge test in a warm bath can be performed to confirm the presence of anaphylaxis. The test should be conducted in an environment in which the patient's airway can be secured and epinephrine can be administered if necessary. Nonsedating antihistamines commonly are used to treat CU, but few other treatments have been thoroughly evaluated for cases that are refractory to antihistamines. We present the case of a 27-year-old US Marine with CU and anaphylaxis confirmed by a water challenge test in a warm bath.
Triggering Descending Pain Inhibition by Observing Ourselves or a Loved-One in Pain.
Gougeon, Véronique; Gaumond, Isabelle; Goffaux, Philippe; Potvin, Stéphane; Marchand, Serge
2016-03-01
Recent studies demonstrate that empathy-evoked brain responses include the activation of brainstem structures responsible for triggering descending pain inhibition. Unfortunately, direct evidence linking empathy for pain and descending inhibitory controls (conditioned pain modulation) is lacking. This study, therefore, aimed to determine if the observation of ourselves or a loved-one in pain could activate descending pain inhibition without exposure to a noxious stimulation; which is otherwise required. Descending pain inhibition was triggered by immersing the right arm of participants (15 heterosexual couples; mean age±SE: 28.89±2.14) in a bath of cold water. The effects of empathy on descending pain inhibition were observed by immersing the right arm of participants in a bath of lukewarm water while having them watch a video of either themselves or their spouse during a previous nociceptive immersion. Immersion of the arm in a bath of lukewarm water without empathic (video) observation was also included as a control condition. A strong inhibitory response activated by the mere observation of the video of themselves or their spouse in pain without a nociceptive conditioning stimulus. Associative statistics also showed that strong pain catastrophizing responses while watching the video resulted in stronger pain inhibition. Moreover, high levels of empathy were associated with stronger pain inhibition, but only for women. This study showed that observing someone in pain triggers descending pain inhibition. Results also demonstrate how empathy and gender are affecting pain modulation mechanisms.
Drinking water disinfection by-products and time to pregnancy.
MacLehose, Richard F; Savitz, David A; Herring, Amy H; Hartmann, Katherine E; Singer, Philip C; Weinberg, Howard S
2008-05-01
Laboratory evidence suggests tap water disinfection by-products (DBPs) could have an effect very early in pregnancy, typically before clinical detectability. Undetected early losses would be expected to increase the reported number of cycles to clinical pregnancy. We investigated the association between specific DBPs (trihalomethanes, haloacetic acids, brominated-trihalomethanes, brominated-haloacetic acids, total organic halides, and bromodichloromethane) and time to pregnancy among women who enrolled in a study of drinking water and reproductive outcomes. We quantified exposure to DBPs through concentrations in tap water, quantity ingested through drinking, quantity inhaled or absorbed while showering or bathing, and total integrated exposure. The effect of DBPs on time to pregnancy was estimated using a discrete time hazard model. Overall, we found no evidence of an increased time to pregnancy among women who were exposed to higher levels of DBPs. A modestly decreased time to pregnancy (ie, increased fecundability) was seen among those exposed to the highest level of ingested DBPs, but not for tap water concentration, the amount absorbed while showering or bathing, or the integrated exposure. Our findings extend those of a recently published study suggesting a lack of association between DBPs and pregnancy loss.
Shrestha, Sadhana; Haramoto, Eiji; Malla, Rabin; Nishida, Kei
2015-03-01
Shallow groundwater is the main water source among many alternatives in the Kathmandu Valley, Nepal, which has a rapidly growing population and intermittent piped water supply. Although human pathogens are detected in groundwater, its health effects are unclear. We estimated risk of diarrhoea from shallow groundwater use using quantitative microbial risk assessment. Escherichia coli, Giardia cyst and Cryptosporidium oocyst levels were analysed in dug and tube wells samples. E. coli concentrations were converted to those of enteropathogenic E. coli (EPEC). Risks from EPEC in dug wells and from Cryptosporidium and Giardia in both dug and tube wells were higher than the acceptable limit (<10⁻⁴ infections/person-year) for both drinking and bathing exposures. Risk from protozoan enteropathogens increased the total risk 10,000 times, indicating that ignoring protozoans could lead to serious risk underestimation. Bathing exposure considerably increased risk, indicating that it is an important pathway. Point-of-use (POU) water treatment decreased the risk six-fold and decreased risk overestimation. Because removal efficiency of POU water treatment has the largest impact on total risk, increasing the coverage and efficiency of POU water treatment could be a practical risk management strategy in the Kathmandu Valley and similar settings.
Radon in the Exhaled Air of Patients in Radon Therapy.
Lettner, Herbert; Hubmer, Alexander; Hofmann, Werner; Landrichinger, Julia; Gaisberger, Martin; Winkler-Heil, Renate
2017-11-01
In the Gastein valley, numerous facilities use radon for the treatment of various diseases either by exposure to radon in air or in radon rich thermal water. In this study, six test persons were exposed to radon thermal water in a bathtub and the time-dependent radon activity concentration in the exhaled air was recorded. At temperatures between 38°C and 40°C, the radon activity concentration in the water was about 900 kBq/m3 in a total volume of 600 l, where the patients were exposed for 20 min, while continuously sampling the exhaled air during the bathing and 20 min thereafter. After entering the bath, the exhaled radon activity concentration rapidly increased, reaching some kind of saturation after 20 min exposure. The radon activity concentration in the exhaled air was about 8000 Bq/m3 at the maximum, with higher concentrations for male test persons. The total radon transfer from water to the exhaled air was between 480 and 1000 Bq, which is equivalent to 0.08% and 0.2% of the radon in the water. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Mathematical and physical modeling of thermal stratification phenomena in steel ladles
NASA Astrophysics Data System (ADS)
Putan, V.; Vilceanu, L.; Socalici, A.; Putan, A.
2018-01-01
By means of CFD numerical modeling, a systematic analysis of the similarity between steel ladles and hot-water model regarding natural convection phenomena was studied. The key similarity criteria we found to be dependent on the dimensionless numbers Fr and βΔT. These similarity criteria suggested that hot-water models with scale in the range between 1/5 and 1/3 and using hot water with temperature of 45 °C or higher are appropriate for simulating natural convection in steel ladles. With this physical model, thermal stratification phenomena due to natural convection in steel ladles were investigated. By controlling the cooling intensity of water model to correspond to the heat loss rate of steel ladles, which is governed by Fr and βΔT, the temperature profiles measured in the water bath of the model were to deduce the extent of thermal stratification in liquid steel bath in the ladles. Comparisons between mathematically simulated temperature profiles in the prototype steel ladles and those physically simulated by scaling-up the measured temperatures profiles in the water model showed good agreement. This proved that it is feasible to use a 1/5 scale water model with 45 °C hot water to simulate natural convection in steel ladles. Therefore, besides mathematical CFD models, the physical hot-water model provided an additional means of studying fluid flow and heat transfer in steel ladles.
Effects of sonication radiation on oil recovery by ultrasonic waves stimulated water-flooding.
Mohammadian, Erfan; Junin, Radzuan; Rahmani, Omeid; Idris, Ahmad Kamal
2013-02-01
Due to partial understanding of mechanisms involved in application of ultrasonic waves as enhanced oil recovery method, series of straight (normal), and ultrasonic stimulated water-flooding experiments were conducted on a long unconsolidated sand pack using ultrasonic transducers. Kerosene, vaseline, and SAE-10 (engine oil) were used as non-wet phase in the system. In addition, a series of fluid flow and temperature rise experiments were conducted using ultrasonic bath in order to enhance the understanding about contributing mechanisms. 3-16% increase in the recovery of water-flooding was observed. Emulsification, viscosity reduction, and cavitation were identified as contributing mechanisms. The findings of this study are expected to increase the insight to involving mechanisms which lead to improving the recovery of oil as a result of application of ultrasound waves. Copyright © 2012 Elsevier B.V. All rights reserved.
Protective conversion coating on mixed-metal substrates and methods thereof
O'Keefe, Matthew J.; Maddela, Surender
2016-09-06
Mixed-metal automotive vehicle bodies-in-white comprising ferrous metal surfaces, zinc surfaces, aluminum alloy surfaces, and magnesium alloy surfaces are cleaned and immersed in an aqueous bath comprising an adhesion promoter and an aqueous electrocoat bath (the adhesion promoter may be in the electrocoat bath. The adhesion promoter, which may be a cerium salt, is selected to react with each metal in the body surfaces to form an oxide layer that provides corrosion resistance for the surface and adherence for the deposited polymeric paint coating. The body is cathodic in the electrocoat deposition.
Effect of bath temperature on surface morphology and photocatalytic activity of ZnO nanorods
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sriharan, N.; Senthil, T. S., E-mail: tssenthi@gmail.com; Muthukumarasamy, N.
2016-05-06
ZnO nanorods were prepared by using simple hydrothermal method using four different bath temperatures. All the prepared ZnO nanorods are annealed at 450°C and are characterized by using various techniques such as X-ray diffraction, UV spectra and scanning electron microscopy. Photocatalytic activity of the prepared ZnO nanorods is analyzed. A novel photocatalytic reactor designed with ZnO nanorods prepared at 90°C shows enhanced catalytic efficiency. The role of light irradiation time, bath temperature and surface morphology of the ZnO nanorods on the performance of photocatalytic reaction is analyzed.
Le Merrer, Marie; Clanet, Christophe; Quéré, David; Raphaël, Élie; Chevy, Frédéric
2011-01-01
We measure the deceleration of liquid nitrogen drops floating at the surface of a liquid bath. On water, the friction force is found to be about 10 to 100 times larger than on a solid substrate, which is shown to arise from wave resistance. We investigate the influence of the bath viscosity and show that the dissipation decreases as the viscosity is increased, owing to wave damping. The measured resistance is well predicted by a model imposing a vertical force (i.e., the drop weight) on a finite area, as long as the wake can be considered stationary. PMID:21876186
Rahmani, Ali; Naseri, Mahdi; Salaree, Mohammad Mahdi; Nehrir, Batool
2016-01-01
Introduction: Many patients in coronary care unit (CCU) suffer from decreased sleep quality caused by environmental and mental factors. This study compared the efficacy of foot reflexology massage, foot bath, and a combination of them on the quality of sleep of patients with acute coronary syndrome (ACS). Methods: This quasi-experimental study was implemented on ACS patients in Iran. Random sampling was used to divide the patients into four groups of 35 subjects. The groups were foot reflexology massage, foot bath, a combination of the two and the control group. Sleep quality was measured using the Veran Snyder-Halpern questionnaire. Data were analyzed by SPSS version 13. Results: The mean age of the four groups was 61.22 (11.67) years. The mean sleep disturbance in intervention groups (foot reflexology massage and foot bath groups) during the second and third nights was significantly less than before intervention. The results also showed a greater reduction in sleep disturbance in the combined group than in the other groups when compared to the control group. Conclusion: It can be concluded that the intervention of foot bath and massage are effective in reducing sleep disorders and there was a synergistic effect when used in combination. This complementary care method can be recommended to be implemented by CCU nurses. PMID:28032074
Rahmani, Ali; Naseri, Mahdi; Salaree, Mohammad Mahdi; Nehrir, Batool
2016-12-01
Introduction: Many patients in coronary care unit (CCU) suffer from decreased sleep quality caused by environmental and mental factors. This study compared the efficacy of foot reflexology massage, foot bath, and a combination of them on the quality of sleep of patients with acute coronary syndrome (ACS). Methods: This quasi-experimental study was implemented on ACS patients in Iran. Random sampling was used to divide the patients into four groups of 35 subjects. The groups were foot reflexology massage, foot bath, a combination of the two and the control group. Sleep quality was measured using the Veran Snyder-Halpern questionnaire. Data were analyzed by SPSS version 13. Results: The mean age of the four groups was 61.22 (11.67) years. The mean sleep disturbance in intervention groups (foot reflexology massage and foot bath groups) during the second and third nights was significantly less than before intervention. The results also showed a greater reduction in sleep disturbance in the combined group than in the other groups when compared to the control group. Conclusion: It can be concluded that the intervention of foot bath and massage are effective in reducing sleep disorders and there was a synergistic effect when used in combination. This complementary care method can be recommended to be implemented by CCU nurses.
Thermal care of newborns: drying and bathing practices in Malawi and Bangladesh
Khan, Shane M; Kim, Eunsoo Timothy; Singh, Kavita; Amouzou, Agbessi; Carvajal-Aguirre, Liliana
2018-01-01
Background Thermal care of newborns is one of the recommended strategies to reduce hypothermia, which contributes to neonatal morbidity and mortality. However, data on these two topics have not been collected at the national level in many surveys. In this study, we examine two elements of thermal care: drying and delayed bathing of newborns after birth with the objectives of examining how two countries collected such data and then looking at various associations of these outcomes with key characteristics. Further, we examine the data for potential data quality issues as this is one of the first times that such data are available at the national level. Methods We use data from two nationally-representative household surveys: the Malawi Multiple Indicator Cluster Survey 2014 and the Bangladesh Demographic and Health Survey 2014. We conduct descriptive analysis of the prevalence of these two newborn practices by various socio-demographic, economic and health indicators. Results Our results indicate high levels of immediate drying/drying within 1 hour in Malawi (87%). In Bangladesh, 84% were dried within the first 10 minutes of birth. Bathing practices varied in the two settings; in Malawi, only 26% were bathed after 24 hours but in Bangladesh, 87% were bathed after the same period. While in Bangladesh there were few newborns who were never bathed (less than 5%), in Malawi, over 10% were never bathed. Newborns delivered by a skilled provider tended to have better thermal care than those delivered by unskilled providers. Conclusion These findings reveal gaps in coverage of thermal care and indicate the need to further develop the role of unskilled providers who can give unspecialized care as a means to improve thermal care for newborns. Further work to harmonize data collection methods on these topics is needed to ensure comparable data across countries. PMID:29862028
NASA Astrophysics Data System (ADS)
Edwards, Devin T.; Takahashi, Susumu; Sherwin, Mark S.; Han, Songi
2012-10-01
At 8.5 T, the polarization of an ensemble of electron spins is essentially 100% at 2 K, and decreases to 30% at 20 K. The strong temperature dependence of the electron spin polarization between 2 and 20 K leads to the phenomenon of spin bath quenching: temporal fluctuations of the dipolar magnetic fields associated with the energy-conserving spin "flip-flop" process are quenched as the temperature of the spin bath is lowered to the point of nearly complete spin polarization. This work uses pulsed electron paramagnetic resonance (EPR) at 240 GHz to investigate the effects of spin bath quenching on the phase memory times (TM) of randomly-distributed ensembles of nitroxide molecules below 20 K at 8.5 T. For a given electron spin concentration, a characteristic, dipolar flip-flop rate (W) is extracted by fitting the temperature dependence of TM to a simple model of decoherence driven by the spin flip-flop process. In frozen solutions of 4-Amino-TEMPO, a stable nitroxide radical in a deuterated water-glass, a calibration is used to quantify average spin-spin distances as large as r¯=6.6 nm from the dipolar flip-flop rate. For longer distances, nuclear spin fluctuations, which are not frozen out, begin to dominate over the electron spin flip-flop processes, placing an effective ceiling on this method for nitroxide molecules. For a bulk solution with a three-dimensional distribution of nitroxide molecules at concentration n, we find W∝n∝1/r, which is consistent with magnetic dipolar spin interactions. Alternatively, we observe W∝n for nitroxides tethered to a quasi two-dimensional surface of large (Ø ˜ 200 nm), unilamellar, lipid vesicles, demonstrating that the quantification of spin bath quenching can also be used to discern the geometry of molecular assembly or organization.
Boros, Melinda; Benkó, Rita; Bölcskei, Kata; Szolcsányi, János; Barthó, Loránd; Pethő, Gábor
2013-12-01
The study aimed at validating an increasing-temperature water bath suitable for determining the noxious heat threshold for use in mice. The noxious heat threshold was determined by immersing the tail of the gently held awake mouse into a water container whose temperature was near-linearly increased at a rate of 24°C/min. until the animal withdrew its tail, that is, heating attained the noxious threshold. The effects of standard analgesic, neuroleptic and anxiolytic drugs were investigated in a parallel way on both the noxious heat threshold and the psychomotor activity assessed by the open field test. Morphine, diclofenac and metamizol (dipyrone) elevated the heat threshold of mice with minimum effective doses of 6, 30 and 1000 mg/kg i.p., respectively. These doses of morphine and diclofenac failed to induce any remarkable effect on psychomotor activity in the open field test while that of metamizol exerted a profound inhibition. The anxiolytic diazepam and the neuroleptic droperidol at doses evoking a mild and moderate, respectively, psychomotor inhibition failed to alter the heat threshold. Combination of a subliminal dose of morphine (regarding both antinociceptive and psychomotor inhibitory action) with diclofenac, metamizol, diazepam or droperidol at doses also subliminal regarding the thermal antinociceptive effect elevated the noxious heat threshold without major additional effects in the open field test. It is concluded that the increasing-temperature water bath is suitable for studying the thermal antinociceptive effects of morphine and diclofenac as well as the morphine-sparing action of diclofenac, metamizol, droperidol and diazepam. Behavioural testing is recommended when testing analgesics. © 2013 Nordic Pharmacological Society. Published by John Wiley & Sons Ltd.
Implementation of a Hydrotherapy Protocol to Improve Postpartum Pain Management.
Batten, Meghann; Stevenson, Eleanor; Zimmermann, Deb; Isaacs, Christine
2017-03-01
A growing number of women are seeking alternatives to traditional pharmacologic pain management during birth. While there has been an extensive array of nonpharmacologic options developed for labor, there are limited offerings in the postpartum period. The purpose of this quality improvement project was to implement a hydrotherapy protocol in the early postpartum period to improve pain management for women choosing a nonmedicated birth. The postpartum hydrotherapy protocol was initiated in a certified nurse-midwife (CNM) practice in an urban academic medical center. All women who met criteria were offered a 30-minute warm water immersion bath at one hour postpartum. Pain scores were assessed prior to the bath, at 15 minutes after onset, and again at the conclusion (30 minutes). Women who completed the bath were also asked to complete a brief survey on their experience with postpartum hydrotherapy. In women who used the bath (N = 45), there was a significant reduction in pain scores (P < .001) between the onset of the bath and scores at both 15 minutes and 30 minutes. There was no significant difference between pain scores at 15 minutes and 30 minutes (P = .97). Of those women who completed a survey (n = 43), 97.7% reported both that the bath reduced their pain and improved their birth experience. One hundred percent reported they would use it again in another birth. This project demonstrated successful implementation of a hydrotherapy protocol as an alternative or adjunct to medication for early postpartum pain management that significantly reduced pain and improved the birth experience for those who used it. It offers a nonpharmacologic alternative where there have traditionally been limited options. © 2017 by the American College of Nurse-Midwives.
High resolution projection micro stereolithography system and method
Spadaccini, Christopher M.; Farquar, George; Weisgraber, Todd; Gemberling, Steven; Fang, Nicholas; Xu, Jun; Alonso, Matthew; Lee, Howon
2016-11-15
A high-resolution P.mu.SL system and method incorporating one or more of the following features with a standard P.mu.SL system using a SLM projected digital image to form components in a stereolithographic bath: a far-field superlens for producing sub-diffraction-limited features, multiple spatial light modulators (SLM) to generate spatially-controlled three-dimensional interference holograms with nanoscale features, and the integration of microfluidic components into the resin bath of a P.mu.SL system to fabricate microstructures of different materials.
Short review on chemical bath deposition of thin film and characterization
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mugle, Dhananjay, E-mail: dhananjayforu@gmail.com; Jadhav, Ghanshyam, E-mail: ghjadhav@rediffmail.com
2016-05-06
This reviews the theory of early growth of the thin film using chemical deposition methods. In particular, it critically reviews the chemical bath deposition (CBD) method for preparation of thin films. The different techniques used for characterizations of the chemically films such as X-ray diffractometer (XRD), Scanning electron microscopy (SEM), Transmission electron microscopy (TEM), Electrical conductivity and Energy Dispersive Spectroscopy (EDS) are discussed. Survey shows the physical and chemical properties solely depend upon the time of deposition, temperature of deposition.
78 FR 12416 - Notice of Application for Special Permits
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-22
... submitted in triplicate. If confirmation of receipt of comments is desired, include a self-addressed stamped...-refillable aerosol containers which are not subject to the hot water bath test. (mode 1). [[Page 12417...
A novel tank for DI water reduction in MEMS manufacturing
NASA Astrophysics Data System (ADS)
Raccurt, O.; Tardif, F.; Kerber, L.; Lardin, T.; Vareine, T.
2003-05-01
A new rinsing process is proposed based on the conclusions obtained by simulations. It consists of a combination of piston flows and internal top-to-bottom recycling steps, which decreases the DI water consumption (and associated cost) for the same rinsing efficiency. This novel concept re-using the DI water in situ in the rinsing tank is demonstrated using an industrial bath recently proposed on the market.
USDA-ARS?s Scientific Manuscript database
The purpose of this study was to evaluate the effectiveness of extracting phenolic compounds and antioxidant activity from buckwheat with water, 50% aqueous ethanol, or 100% ethanol using microwave irradiation or a water bath for 15 min at various temperatures (23 – 150 °C). The phenolic content of...
[The changing position of balneo- and hydrotherapy in medicine].
Gömör, Béla
2013-12-01
Therapy with water has been known for thousands of years. Hot water bath was always pleasant for people. During the 19th century it was applied for the treatment of several diseases and modern medicine should not miss it. Today balneotherapy may help gymnastic procedures and it is commonly used in combination with other types of physiotherapy, too.
Do as the Romans: Construct an Aqueduct! Grades 6-8.
ERIC Educational Resources Information Center
Rushton, Erik; Ryan, Emily; Swift, Charles
In this activity, students work with specified materials to create aqueduct components to transport two liters of water across a short distance in the classroom. The goal is to build an aqueduct that will supply Aqueductis, a Roman city, with clean water for private homes, public baths, and glorious fountains. By introducing various ideas and…
Geothermal energy control system and method
Matthews, Hugh B.
1977-01-01
A geothermal energy transfer and utilization system makes use of thermal energy stored in hot solute-bearing well water to generate super-heated steam from an injected flow of clean water; the super-heated steam is then used for operating a turbine-driven pump at the well bottom for pumping the hot solute-bearing water at high pressure and in liquid state to the earth's surface, where it is used by transfer of its heat to a closed-loop boiler-turbine-alternator combination for the generation of electrical or other power. Residual concentrated solute-bearing water is pumped back into the earth. The clean cooled water is regenerated at the surface-located system and is returned to the deep well pumping system also for lubrication of a novel bearing arrangement supporting the turbine-driven pump system. The bearing system employs liquid lubricated thrust and radial bearings with all bearing surfaces bathed in clean water serving as a lubricant and maintained under pressure to prevent entry into the bearings of contaminated geothermal fluid, an auxiliary thrust ball bearing arrangement comes into operation when starting or stopping the pumping system.
Calibration and Field Deployment of the NSF G-V VCSEL Hygrometer
NASA Astrophysics Data System (ADS)
DiGangi, J. P.; O'Brien, A.; Diao, M.; Hamm, C.; Zhang, Q.; Beaton, S. P.; Zondlo, M. A.
2012-12-01
Cloud formation and dynamics have a significant influence on the Earth's radiative forcing budget, which illustrates the importance of clouds with respect to global climate. Therefore, an accurate understanding of the microscale processes dictating cloud formation is crucial for accurate computer modeling of global climate change. A critical tool for understanding these processes from an airborne platform is an instrument capable of measuring water vapor with both high accuracy and time, thus spatial, resolution. Our work focuses on an open-path, compact, vertical-cavity surface-emitting laser (VCSEL) absorption-based hygrometer, capable of 25 Hz temporal resolution, deployed on the NSF/NCAR Gulfstream-V aircraft platform. The open path nature of our instrument also helps to minimize sampling artifacts. We will discuss our efforts toward achieving within 5% accuracy over 5 orders of magnitude of water vapor concentrations. This involves an intercomparison of five independent calibration methods: ice surface saturators using an oil temperature bath, solvent slush baths (e.g. chloroform/LN2, water/ice), a research-grade frost point hygrometer, static pressure experiments, and Pt catalyzed hydrogen gas. This wide variety of available tools allows us to accurately constrain the calibrant water vapor concentrations both before and after the VCSEL hygrometer sampling chamber. For example, the mixing ratio as measured by research-grade frost point hygrometer after the VCSEL hygrometer agreed within 2% of the mixing ration expected from the water/ice bubbler source before the VCSEL over the temperature range -50°C to 20°C. Finally, due to the compact nature of our instrument, we are able to perform these calibrations simultaneously at the same temperatures (-80°C to 30°C) and pressures (150 mbar to 760 mbar) as sampled ambient air during a flight. This higher accuracy can significantly influence the science utilizing this data, which we will illustrate using preliminary data from our most recent field deployment, the NSF Deep Convective Clouds and Chemistry Experiment in May-June 2012
DOE Office of Scientific and Technical Information (OSTI.GOV)
Luijk, Peter van; Faber, Hette; Schippers, Jacobus M.
2009-07-15
Purpose: To assess in a rat model whether adding a subtolerance dose in a region adjacent to a high-dose irradiated subvolume of the parotid gland influences its response (bath-and-shower effect). Methods and Materials: Irradiation of the whole, cranial 50%, and/or the caudal 50% of the parotid glands of Wistar rats was performed using 150-MeV protons. To determine suitable (i.e., subtolerance) dose levels for a bath-dose, both whole parotid glands were irradiated with 5 to 25 Gy. Subsequently groups of Wistar rats received 30 Gy to the caudal 50% (shower) and 0 to 10 Gy to the cranial 50% (bath) ofmore » both parotid glands. Stimulated saliva flow rate (function) was measured before and up to 240 days after irradiation. Results: Irradiation of both glands up to a dose of 10 Gy did not result in late loss of function and is thus regarded subtolerance. Addition of a dose bath of 1 to 10 Gy to a high-dose in the caudal 50% of the glands resulted in enhanced function loss. Conclusion: Similar to the spinal cord, the parotid gland demonstrates a bath and shower effect, which may explain the less-than-expected sparing of function after IMRT.« less
Study on cryopreservation of Porphyra yezoensis conchocelis
NASA Astrophysics Data System (ADS)
Zhou, Wenjun; Li, Yun; Dai, Jixun
2007-07-01
Cryopreservation of Porphyra yezoensis conchocelis was conducted with cryoprotectants and a proposed pretreatment procedure and thawing methods explored. Six cryoprotectants combined by DMSO with ethylene glycol (EG), propylene glycol (PEG), sorbitol and sucrose were developed. The effect of prefreezing at -40°C or -20°C for different time durations was compared and the thawing methods were screened. It was shown that the cryoprotectant including 10% DMSO with 0.5 molL-1 sorbitol exhibited the optimal effect. The ideal pretreatment was that conchocelis segments were stayed for 20 min at -40°C before stored in liquid nitrogen, and 40°C water bath was proper for quick thawing. The highest recovery rate of cryopreserved P. yezoensis conchocelis reached 89.41%.
Total focusing method with correlation processing of antenna array signals
NASA Astrophysics Data System (ADS)
Kozhemyak, O. A.; Bortalevich, S. I.; Loginov, E. L.; Shinyakov, Y. A.; Sukhorukov, M. P.
2018-03-01
The article proposes a method of preliminary correlation processing of a complete set of antenna array signals used in the image reconstruction algorithm. The results of experimental studies of 3D reconstruction of various reflectors using and without correlation processing are presented in the article. Software ‘IDealSystem3D’ by IDeal-Technologies was used for experiments. Copper wires of different diameters located in a water bath were used as a reflector. The use of correlation processing makes it possible to obtain more accurate reconstruction of the image of the reflectors and to increase the signal-to-noise ratio. The experimental results were processed using an original program. This program allows varying the parameters of the antenna array and sampling frequency.
Study on the method of maintaining bathtub water temperature
NASA Astrophysics Data System (ADS)
Wang, Xiaoyan
2017-05-01
In order to make the water temperature constant and the spillage to its minimum, we use finite element method and grid transformation and have established an optimized model for people in the bathtub both in time and space, which is based on theories of heat convection and heat conduction and three-dimensional second-order equation. For the first question, we have worked out partial differential equations for three-dimensional heat convection. In the meantime, we also create an optimized temperature model in time and space by using initial conditions and boundary conditions. For the second question we have simulated the shape and volume of the tub and the human gestures in the tub based on the first question. As for the shape and volume of the tub, we draw conclusion that the tub whose surface area is little contains water with higher temperature. Thus, when we are designing bathtubs we can decrease the area so that we'll have less loss heat. For different gestures when people are bathing, we have found that gestures have no obvious influence on variations of water temperature. Finally, we did some simulating calculations, and did some analysis on precision and sensitivity
Meyers, Kathleen; Kaynak, Övgü; Bresani, Elena; Curtis, Brenda; McNamara, Ashley; Brownfield, Kristine; Kirby, Kimberly C.
2015-01-01
Background “Bath salts”, a derivative of cathinone, a naturally occurring beta-ketone amphetamine analogue found in the leaves of the khat (Catha edulis) plant, is a potent class of designer drugs associated with significant medical and psychiatric consequences. They are commonly used among 20 to 29 year olds, a group with easy access to the internet and an inclination to purchase online. Therefore, the internet has the potential to play a significant role in the distribution and associated consequences of these “legal highs”. Methods Google searches were used to determine bath salts availability on retail websites and how different search terms affected the proportion of retail websites obtained. Retail websites were reviewed by two independent raters who examined content with a focus on characteristics that increase the likelihood of online sales. Results Of the 250 websites found, 31 were unique retail websites. Most retail website hits resulted when a product name was used as the search term. The top three countries hosting retail websites were registered in the United States (n=14; 45%), Germany (n=7; 23%), and the United Kingdom (n=3; 10%). These online drug suppliers provided considerable information and purchasing choice about a variety of synthetic cathinones, legitimized their sites by using recognizable images, online chat features, and mainstream payment and shipping methods, and employed characteristics that promote online purchases. Conclusion Online designer drug suppliers use sophisticated methods to market unregulated products to consumers. The international community has taken diverse approaches to address designer drugs: legislative bans, harm reduction approaches, an interim regulated legal market. Multifaceted efforts that target bath salt users, suppliers, and emergency/poison control entities are critical to comprehensively address bath salt ingestion and its consequences. PMID:25641258
NASA Technical Reports Server (NTRS)
Deckman, G.; Rousseau, J. (Editor)
1973-01-01
The Wash Water Recovery System (WWRS) is intended for use in processing shower bath water onboard a spacecraft. The WWRS utilizes flash evaporation, vapor compression, and pyrolytic reaction to process the wash water to allow recovery of potable water. Wash water flashing and foaming characteristics, are evaluated physical properties, of concentrated wash water are determined, and a long term feasibility study on the system is performed. In addition, a computer analysis of the system and a detail design of a 10 lb/hr vortex-type water vapor compressor were completed. The computer analysis also sized remaining system components on the basis of the new vortex compressor design.
Apparatus and method for controlling plating uniformity
Hachman Jr., John T.; Kelly, James J.; West, Alan C.
2004-10-12
The use of an insulating shield for improving the current distribution in an electrochemical plating bath is disclosed. Numerical analysis is used to evaluate the influence of shield shape and position on plating uniformity. Simulation results are compared to experimental data for nickel deposition from a nickel--sulfamate bath. The shield is shown to improve the average current density at a plating surface.
NASA Astrophysics Data System (ADS)
Bai, Shengchi; Wang, Haifeng; Yang, Hui; Zhang, He; Guo, Xingzhong
2018-02-01
Silver nanowires (AgNWs)-polyurethane (PU) composite transparent conductive films were fabricated via transfer method using AgNWs conductive inks and polyurethane as starting materials, and the effects of post-treatments including heat treatment, NaCl solution bath and HCl solution bath for AgNWs film on the sheet resistance and transmittance of the composite films were respectively investigated in detail. AgNWs networks are uniformly embedded in the PU layer to improve the adhesion and reduce the surface roughness of AgNWs-PU composite films. Heat treatment can melt and weld the nanowires, and NaCl and HCl solution baths promote the dissolution and re-deposition of silver and the dissolving of the polymer, both which form conduction pathways and improve contact of AgNWs for reducing the sheet resistance. Smooth and flexible AgNWs-PU composite film with a transmittance of 85% and a sheet resistance of 15 Ω · sq‑1 is obtained after treated in 0.5 wt% HCl solution bath for 60 s, and the optoelectronic properties of the resultant composite film can maintain after 1000 cycles of bending and 100 days.
Method for regeneration of electroless nickel plating solution
Eisenmann, Erhard T.
1997-01-01
An electroless nickel(EN)/hypophosphite plating bath is provided employing acetic acid/acetate as a buffer and which is, as a result, capable of perpetual regeneration while avoiding the production of hazardous waste. A regeneration process is provided to process the spent EN plating bath solution. A concentrated starter and replenishment solution is provided for ease of operation of the plating bath. The regeneration process employs a chelating ion exchange system to remove nickel cations from spent EN plating solution. Phosphites are then removed from the solution by precipitation. The nickel cations are removed from the ion exchange system by elution with hypophosphorous acid and the nickel concentration of the eluate adjusted by addition of nickel salt. The treated solution and adjusted eluate are combined, stabilizer added, and the volume of resulting solution reduced by evaporation to form the bath starter and replenishing solution.
Method for regeneration of electroless nickel plating solution
Eisenmann, E.T.
1997-03-11
An electroless nickel(EN)/hypophosphite plating bath is provided employing acetic acid/acetate as a buffer and which is, as a result, capable of perpetual regeneration while avoiding the production of hazardous waste. A regeneration process is provided to process the spent EN plating bath solution. A concentrated starter and replenishment solution is provided for ease of operation of the plating bath. The regeneration process employs a chelating ion exchange system to remove nickel cations from spent EN plating solution. Phosphites are then removed from the solution by precipitation. The nickel cations are removed from the ion exchange system by elution with hypophosphorus acid and the nickel concentration of the eluate adjusted by addition of nickel salt. The treated solution and adjusted eluate are combined, stabilizer added, and the volume of resulting solution reduced by evaporation to form the bath starter and replenishing solution. 1 fig.
On the Growth of Ice in Aqueous Solutions Contained in Capillaries
NASA Astrophysics Data System (ADS)
Pruppracher, H. R.
1967-06-01
The growth rate of ice in supercooled water and in dilute aqueous solutions of various salts which dissociate in water into univalent ions was studied. The solutions contained in polyethylene tubes of small bore had concentrations between 10-6 and 10-1 moles liter-1 and were investigated at bath supercoolings between 1° and 15°C. The growth rate of ice which in pure water was found to vary approximately with the square of the bath supercooling was affected in a systematic manner by the type and concentration of the salt in solution. At salt concentrations smaller than 5 × 10-2 moles liter-1 most salts did not affect the growth rate. However, the fluorides were found to increase the growth rate over and above the one in pure water. At concentrations larger than 5 × 10-2 moles liter-1 all the salts reduced the growth rate of ice below the one in pure water. By comparing solutions of salts with common anion it was found that at a particular bath supercooling and salt concentration the growth rate of ice was reduced most in lithium solutions and least in cesium and ammonium solutions. By comparing solutions of salts with common cation it was found that the growth rate of ice was reduced most in fluoride solutions and least in bromide solutions. It was concluded that in solutions with salt concentrations larger than 5 × 10-2 moles liter-1 the rate of dissipation of latent heat which controls the growth rate of ice is affected in a systematic manner by the freezing point lowering effects which result from pure mass transfer conditions prevailing at the ice-solution interface of a stagnant system. Some features of the observed growth rates are discussed in terms of the effect of dissolved salts on the growth forms of ice in aqueous solutions.
Comparative study of the thermal properties of mud and peat solutions applied in clinical practice.
Beer, A M; Grozeva, A; Sagorchev, P; Lukanov, J
2003-11-01
Different peloids as e.g. mud and peat have been traditionally used for therapeutic purposes successfully, especially of there thermal actions. It was the aim of the experimental study to compare the thermal properties of two peloids, mud and peat, with a view to assessing their thermal effects when they are applied in clinical practice. The studies were carried out using peat of the marsh type of peats (Hochmoor), and curative Pomorie (Bulgaria) mud. As important parameters were determined the specific thermal capacity at constant pressure (Cp), the density of solutions (rho), the cooling rate (m), the coefficient of temperature transfer (a) of solutions and the coefficient of thermal conductivity (lambda) of solutions of peat and curative mud, compared to water bath. The comparative studies of the thermal properties of water and water solutions of peat and curative mud show that the thermal effect of the water bath is substantially smaller than that of the peat and mud applications. This difference is due to a greater extent to the high values of the dynamic viscosity, not allowing cooling by convection and protecting the surface of the skin upon applications of peloid solutions with a higher temperature.
Pseudomonas folliculitis in Arabian baths.
Molina-Leyva, Alejandro; Ruiz-Ruigomez, Maria
2013-07-14
A 35-year-old man presented with a painful cutaneous skin eruption that was localized on the upper trunk. He stated that the previous weekend he had attended an Arabian bath. The physical examination revealed multiple hair follicle-centered papulopustules surrounded by an erythematous halo. A clinical diagnosis of pseudomonas folliculitis was made and treatment was prescribed. Afterwards Pseudomonas aeruginosa was isolated from a pustule culture. Pseudomonas folliculitis is a bacterial infection of the hair follicles. The most common reservoirs include facilities with hot water and complex piping systems that are difficult to clean, such as hot tubs and bathtubs. Despite adequate or high chlorine levels, Pseudomonas aeruginosa can grow within a biofilm.
Heß, Stefanie; Lüddeke, Frauke; Gallert, Claudia
2016-10-01
Whereas the hygienic condition of drinking and bathing water by law must be monitored by culture-based methods, for quantification of microbes and antibiotic resistance in soil or the aquatic environment, often molecular genetic assays are used. For comparison of both methods, knowledge of their correlation is necessary. Therefore the population of total bacteria, Escherichia coli, enterococci and staphylococci during sewage treatment and in receiving river water was compared by agar plating and quantitative polymerase chain reaction (qPCR) assays. In parallel, all samples were investigated for clinically relevant antibiotic resistance genes. Whereas plating and qPCR data for total bacteria correlated well in sewage after primary treatment, qPCR data of river water indicated higher cell numbers for E. coli. It is unknown if these cells are 'only' not growing under standard conditions or if they are dead. Corresponding to the amount of non-culturable cells, the 'breakpoints' for monitoring water quality should be adapted. The abundances of clinically relevant antibiotic resistance genes in river water were in the same order of magnitude or even higher than in treated sewage. For estimation of the health risk it is important to investigate which species carry respective genes and whether these genes are disseminated via gene transfer.
Pseudomonas aeruginosa Dose-Response and Bathing Water Infection
Pseudomonas aeruginosa is the most commonly identified opportunistic pathogen associated with pool acquired bather disease. To better understand why this microorganism poses this protracted problem we recently appraised P. aeruginosa pool risk management. Much is known about the ...
ERIC Educational Resources Information Center
Lawrence, Allen
Tips are given here for energy conservation in the home. Included are heating and cooling houses, water heating, bathing, clothes washing and drying, cooking, refrigerating, dishwashing, lighting, and driving. Also included is a table of annual energy requirements of household electric appliances. (BB)
Dichromated-gelatin hologram process for improved optical quality
NASA Technical Reports Server (NTRS)
Stewart, W. C.
1975-01-01
Optical distortions are eliminated by use of wetting agency followed by sequential immersion in several alcohol-water baths of increasing alcohol concentration. Dehydration proceeds uniformly over surface of gelatin. Dried plate is free of optically-distorting thickness variations.
Concentration of Trichloroethylene in Breast Milk and Household Water from Nogales, Arizona
Beamer, Paloma I.; Luik, Catherine E.; Abrell, Leif; Campos, Swilma; Martínez, María Elena; Sáez, A. Eduardo
2013-01-01
The United States Environmental Protection Agency has identified quantification of trichloroethylene (TCE), an industrial solvent, in breast milk as a high priority need for risk assessment. Water and milk samples were collected from 20 households by a lactation consultant in Nogales, Arizona. Separate water samples (including tap, bottled and vending machine) were collected for all household uses: drinking, bathing, cooking, and laundry. A risk factor questionnaire was administered. Liquid-liquid extraction with diethyl ether was followed by GC-MS for TCE quantification in water. Breast milk underwent homogenization, lipid hydrolysis and centrifugation prior to extraction. The limit of detection was 1.5 ng/mL. TCE was detected in 7 of 20 mothers’ breast milk samples. The maximum concentration was 6 ng/mL. TCE concentration in breast milk was significantly correlated with the concentration in water used for bathing (ρ=0.59, p=0.008). Detection of TCE in breast milk was more likely if the infant had a body mass index <14 (RR=5.2, p=0.02). Based on average breast milk consumption, TCE intake for 5% of the infants may exceed the proposed US EPA Reference Dose. Results of this exploratory study warrant more in depth studies to understand risk of TCE exposures from breast milk intake. PMID:22827160
Chumngoen, Wanwisa; Chen, Hsin-Yi; Tan, Fa-Jui
2016-12-01
Under laboratory conditions, the qualities of boneless chicken breasts are commonly determined by placing them in a bag and cooking them in a water bath. The results are often applied as references for comparing the influences of cooking techniques. However, whether a sample cooked under this "laboratory" condition actually represents the meat cooked under the "real-life" condition in which meat is frequently cooked directly in water without packaging remains unclear. Whether the two cooking conditions lead to comparable results in meat quality should be determined. This study evaluated the influence of cooking conditions, including "placed-in-bag and cooked in a water bath (BC)" and "cooked directly in hot water (WC)" conditions, on the quality of chicken meat. The results reveal that BC samples had a longer cooking time. Deboned-and-skinless BC samples had a higher cooking loss and lower protein solubility (P < 0.01). BC samples with bone and skin had a higher lightness in both skin and muscle. No significant differences were observed in attributes, including shear force, collagen solubility, microstructures, redness, yellowness and descriptive sensory characteristics between treatments. Based on the results, considering the quality attributes that might be influenced, is critical when conducting relevant research. © 2016 Japanese Society of Animal Science.
[Homeopathy and structure of water: a physical model].
Kratky, K W
2004-02-01
Formerly, the author has suggested a relatively simple water model. There, the dynamical structure of a typical water cluster was investigated, being represented by the movement of a ball in an abstract energy landscape. Now the above-mentioned model is investigated in more detail to answer the following question: Are essential claims of homeopathy concerning potentiation (diluting and shaking) in agreement with science? Equations of motion are employed that represent vibrations of clusters. For the computer experiments, the formalism of Nosé-Hoover is used, the surrounding water being interpreted as a heat bath. Diluting corresponds to a shift of the energy landscape towards the pure solvent (water), shaking is accompanied by an increase of the contact to the heat bath. There is a tendency of the ball to be caught in local valleys of the energy landscape (metastable states) if the temperature is not too high and if the liquid is not shaken. Thus, even for a given landscape there are a variety of structures being durable for some time. The computer experiments suggest that the repeated process of potentiation eventually results in a specific metastable state of the pure solvent. The initial substance helps to obtain this goal, but is no longer necessary at last. Copyright 2004 S. Karger GmbH, Freiburg
Archaea S-layer nanotube from a "black smoker" in complex with cyclo-octasulfur (S8 ) rings.
McDougall, Matthew; Francisco, Olga; Harder-Viddal, Candice; Roshko, Roy; Meier, Markus; Stetefeld, Jörg
2017-12-01
Elemental sulfur exists primarily as an S80 ring and serves as terminal electron acceptor for a variety of sulfur-fermenting bacteria. Hyperthermophilic archaea from black smoker vents are an exciting research tool to advance our knowledge of sulfur respiration under extreme conditions. Here, we use a hybrid method approach to demonstrate that the proteinaceous cavities of the S-layer nanotube of the hyperthermophilic archaeon Staphylothermus marinus act as a storage reservoir for cyclo-octasulfur S8. Fully atomistic molecular dynamics (MD) simulations were performed and the method of multiconfigurational thermodynamic integration was employed to compute the absolute free energy for transferring a ring of elemental sulfur S8 from an aqueous bath into the largest hydrophobic cavity of a fragment of archaeal tetrabrachion. Comparisons with earlier MD studies of the free energy of hydration as a function of water occupancy in the same cavity of archaeal tetrabrachion show that the sulfur ring is energetically favored over water. © 2017 Wiley Periodicals, Inc.
Magnetic Catheter Manipulation in the Interventional MRI Environment
Wilson, Mark W.; Martin, Alastair B.; Lillaney, Prasheel; Losey, Aaron D.; Yee, Erin J.; Bernhardt, Anthony; Malba, Vincent; Evans, Lee; Sincic, Ryan; Saeed, Maythem; Arenson, Ronald L.; Hetts, Steven W.
2013-01-01
Purpose To evaluate deflection capability of a prototype endovascular catheter, which is remotely magnetically steerable, for use in the interventional MRI environment. Materials and Methods Copper coils were mounted on the tips of commercially available 2.3 – 3.0 Fr microcatheters. The coils were fabricated in a novel manner by plasma vapor deposition of a copper layer followed by laser lithography of the layer into coils. Orthogonal helical (solenoid) and saddle-shaped (Helmholtz) coils were mounted on a single catheter tip. Microcatheters were tested in water bath phantoms in a 1.5T clinical MRI scanner, with variable simultaneous currents applied to the coils. Catheter tip deflection was imaged in the axial plane utilizing a “real-time” steady-state free precession (SSFP) MRI sequence. Degree of deflection and catheter tip orientation were measured for each current application. Results The catheter tip was clearly visible in the longitudinal and axial planes. Magnetic field artifacts were visible when the orthogonal coils at the catheter tip were energized. Variable amounts of current applied to a single coil demonstrated consistent catheter deflection in all water bath experiments. Changing current polarity reversed the observed direction of deflection, whereas current applied to two different coils resulted in deflection represented by the composite vector of individual coil activations. Microcatheter navigation through the vascular phantom was successful through control of applied current to one or more coils. Conclusion Controlled catheter deflection is possible with laser lithographed multi-axis coil tipped catheters in the MRI environment. PMID:23707097
Anaerobic sequencing batch reactor in pilot scale for treatment of tofu industry wastewater
NASA Astrophysics Data System (ADS)
Rahayu, Suparni Setyowati; Purwanto, Budiyono
2015-12-01
The small industry of tofu production process releases the waste water without being processed first, and the wastewater is directly discharged into water. In this study, Anaerobic Sequencing Batch Reactor in Pilot Scale for Treatment of Tofu Industry was developed through an anaerobic process to produce biogas as one kind of environmentally friendly renewable energy which can be developed into the countryside. The purpose of this study was to examine the fundamental characteristics of organic matter elimination of industrial wastewater with small tofu effective method and utilize anaerobic active sludge with Anaerobic Sequencing Bath Reactor (ASBR) to get rural biogas as an energy source. The first factor is the amount of the active sludge concentration which functions as the decomposers of organic matter and controlling selectivity allowance to degrade organic matter. The second factor is that HRT is the average period required substrate to react with the bacteria in the Anaerobic Sequencing Bath Reactor (ASBR).The results of processing the waste of tofu production industry using ASBR reactor with active sludge additions as starter generates cumulative volume of 5814.4 mL at HRT 5 days so that in this study it is obtained the conversion 0.16 L of CH4/g COD and produce biogas containing of CH4: 81.23% and CO2: 16.12%. The wastewater treatment of tofu production using ASBR reactor is able to produce renewable energy that has economic value as well as environmentally friendly by nature.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rahayu, Suparni Setyowati, E-mail: suparnirahayu@yahoo.co.id; Department of Mechanical Engineering, State Polytechnic of Semarang, Semarang Indonesia; Purwanto,, E-mail: p.purwanto@che.undip.ac.id
The small industry of tofu production process releases the waste water without being processed first, and the wastewater is directly discharged into water. In this study, Anaerobic Sequencing Batch Reactor in Pilot Scale for Treatment of Tofu Industry was developed through an anaerobic process to produce biogas as one kind of environmentally friendly renewable energy which can be developed into the countryside. The purpose of this study was to examine the fundamental characteristics of organic matter elimination of industrial wastewater with small tofu effective method and utilize anaerobic active sludge with Anaerobic Sequencing Bath Reactor (ASBR) to get rural biogasmore » as an energy source. The first factor is the amount of the active sludge concentration which functions as the decomposers of organic matter and controlling selectivity allowance to degrade organic matter. The second factor is that HRT is the average period required substrate to react with the bacteria in the Anaerobic Sequencing Bath Reactor (ASBR).The results of processing the waste of tofu production industry using ASBR reactor with active sludge additions as starter generates cumulative volume of 5814.4 mL at HRT 5 days so that in this study it is obtained the conversion 0.16 L of CH{sub 4}/g COD and produce biogas containing of CH{sub 4}: 81.23% and CO{sub 2}: 16.12%. The wastewater treatment of tofu production using ASBR reactor is able to produce renewable energy that has economic value as well as environmentally friendly by nature.« less
Quality of Life of Psoriasis Patients before and after Balneo - or Balneophototherapy
Calza, Anna; Di Pietro, Cristina; Sampogna, Francesca; Abeni, Damiano
2009-01-01
Purpose An observational prospective study was conducted to study the effects of hypotonic spa-water baths and narrowband ultraviolet B therapy given alone or in combination for treatment of moderate-severe psoriasis. Materials and Methods Two treatments were analysed: 2 weeks of balneotherapy followed by ultraviolet-B (UVB) 311-nm phototherapy (BPT) or 2 weeks of daily bath treatments of Comano water alone (BT). One hundred and eleven adult patients with moderate to severe chronic plaque psoriasis were enrolled. Quality of life (QoL) questionnaires {36-item Short Form of the Medical Outcomes Study questionnaire (SF-36) and Skindex-29} were administered at baseline and 2 months from the end of therapy. The self-administered Psoriasis Area Severity Index (SAPASI), and the General Health Questionnaire (GHQ)-12 (to assess clinical severity and psychological distress, respectively) were also recorded at the same time-periods. Results SAPASI was significantly reduced from 15.2 to 8.7 in BPT group and 11.6 to 7.8 in BT. A decrease of greater than 50% after therapy in SAPASI_50 score was reached by 42% and 37% of patients in the BPT and BT groups, respectively. At follow-up, both groups had better scores on all SF-36 scales (with statistically significant improvement in social functioning and mental health in the BPT group) and in all Skindex-29 scales. A statistically significant reduction of GHQ-12 positive cases was observed in the BPT group. Conclusion Comano spa-water alone or in combination with phototherapy had beneficial therapeutic effects on patients with psoriasis. Although our observational study design prevents us from making meaningful comparisons between the 2 interventions, the combination of balneo and phototherapy seems to improve QoL and lessen clinical severity, and reduced the proportion of GHQ-12 positive cases. PMID:19430554
Texture related unusual phenomena in electrodeposition and vapor deposition
NASA Astrophysics Data System (ADS)
Lee, D. N.; Han, H. N.
2015-04-01
The tensile strength of electrodeposits generally decreases with increasing bath temperature because the grain size increases and the dislocation density decreases with increasing bath temperature. Therefore, discontinuities observed in the tensile strength vs. bath temperature curves in electrodeposition of copper are unusual. The tensile strength of electrodeposits generally increases with increasing cathode current density because the rate of nucleation in electrodeposits increases with increasing current density, which in turn gives rise to a decrease in the grain size and in turn an increase in the strength. Therefore, a decrease in the tensile strength of copper electrodeposits at a high current density is unusual. The grain size of vapor deposits is expected to decrease with decreasing substrate temperature. However, rf sputtered Co-Cr deposits showed that deposits formed on water-cooled polyimide substrates had a larger grain size than deposits formed on polyimide substrates at 200 °C. These unusual phenomena can be explained by the preferred growth model for deposition texture evolution.
Hydrogen peroxide measurements in recreational marine bathing waters in Southern California, USA.
Clark, Catherine D; De Bruyn, Warren J; Hirsch, Charlotte M; Jakubowski, Scott D
2010-04-01
Hydrogen peroxide (H(2)O(2)) was measured in the surf zone at 13 bathing beaches in Southern California, USA. Summer dry season concentrations averaged 122 +/- 38 nM with beaches with tide pools having lower levels (50-90 nM). No significant differences were observed for ebb waters at a salt marsh outlet vs. a beach (179 +/- 20 vs. 163 +/- 26 nM), and between ebb and flood tides at one site (171 +/- 24 vs. 146 +/- 42 nM). H(2)O(2) levels showed little annual variation. Diel cycling was followed over short (30 min; 24 h study) and long (d) time scales, with maximum afternoon concentration = 370 nM and estimated photochemical production rate of 44 nM h(-1). There was no correlation between the absorbance coefficient at 300 nm (used as a measure of chromophoric dissolved organic matter (CDOM) levels) and H(2)O(2). H(2)O(2) concentrations measured in this study are likely sufficient to inhibit fecal indicator bacteria in marine recreational waters through indirect photoinactivation. Copyright (c) 2009 Elsevier Ltd. All rights reserved.
Oillic, Samuel; Lemoine, Eric; Gros, Jean-Bernard; Kondjoyan, Alain
2011-07-01
Cooking loss kinetics were measured on cubes and parallelepipeds of beef Semimembranosus muscle ranging from 1 cm × 1 cm × 1 cm to 7 cm × 7 cm × 28 cm in size. The samples were water bath-heated at three different temperatures, i.e. 50°C, 70°C and 90°C, and for five different times. Temperatures were simulated to help interpret the results. Pre-freezing the sample, difference in ageing time, and in muscle fiber orientation had little influence on cooking losses. At longer treatment times, the effects of sample size disappeared and cooking losses depended only on the temperature. A selection of the tests was repeated on four other beef muscles and on veal, horse and lamb Semimembranosus muscle. Kinetics followed similar curves in all cases but resulted in different final water contents. The shape of the kinetics curves suggests first-order kinetics. Copyright © 2011 The American Meat Science Association. Published by Elsevier Ltd. All rights reserved.
Study of neutron spectra in a water bath from a Pb target irradiated by 250 MeV protons
NASA Astrophysics Data System (ADS)
Li, Yan-Yan; Zhang, Xue-Ying; Ju, Yong-Qin; Ma, Fei; Zhang, Hong-Bin; Chen, Liang; Ge, Hong-Lin; Wan, Bo; Luo, Peng; Zhou, Bin; Zhang, Yan-Bin; Li, Jian-Yang; Xu, Jun-Kui; Wang, Song-Lin; Yang, Yong-Wei; Yang, Lei
2015-04-01
Spallation neutrons were produced by the irradiation of Pb with 250 MeV protons. The Pb target was surrounded by water which was used to slow down the emitted neutrons. The moderated neutrons in the water bath were measured by using the resonance detectors of Au, Mn and In with a cadmium (Cd) cover. According to the measured activities of the foils, the neutron flux at different resonance energies were deduced and the epithermal neutron spectra were proposed. Corresponding results calculated with the Monte Carlo code MCNPX were compared with the experimental data to check the validity of the code. The comparison showed that the simulation could give a good prediction for the neutron spectra above 50 eV, while the finite thickness of the foils greatly effected the experimental data in low energy. It was also found that the resonance detectors themselves had great impact on the simulated energy spectra. Supported by National Natural Science Foundation and Strategic Priority Research Program of the Chinese Academy of Sciences (11305229, 11105186, 91226107, 91026009, XDA03030300)
Whole body cleaning agent containing N-acyltaurate
NASA Technical Reports Server (NTRS)
Lentsch, Steven E. (Inventor)
1992-01-01
The subject invention relates to a human cleansing agent particularly suitable for use in long duration spaceflight and to a method of bathing with the agent. The agent of the subject invention is in the form of a paste having a pH of 5.0 to 7.9 which comprises an acyltaurate, a skin conditioner, a hair conditioner, and a preservative. More specifically, it includes sodium N-coconut acid-N-methyl taurate, in combination with soybean lecithin, polyquaternium 16, and formalin. This particular combination satisfies the following objectives: (1) that it be usable with a minimum amount of water per shower (approximately 1 gallon); (2) that it be easily separated from the water for purposes of water reclamation; (3) that it be pH compatible with skin and hair; (4) that it rinse well in deionized water; (5) that it be mild to skin and eyes; (6) that it effectively clean both skin and hair; (7) that it be suitable for use in zero gravity; and (8) that it provide ease of combing of wet and dry hair. The method of the invention includes the steps of wetting the skin and hair with a small quantity of water, lathering the skin with the paste, rinsing the lather from the skin and hair with a small quantity of water to produce a rinse water containing the cleansing agent, defoaming the rinse water, and supplying the defoamed rinse water to a water reclamation unit for recycling the water. The novelty of the invention appears to lie in the particular formulation of the cleansing agent and its method of use which provide optimal results under the given constraints and objectives.
Systems and Methods for the Electrodeposition of a Nickel-cobalt Alloy
NASA Technical Reports Server (NTRS)
Ogozalek, Nance Jo (Inventor); Wistrand, Richard E. (Inventor)
2013-01-01
Systems and methods for electrodepositing a nickel-cobalt alloy using a rotating cylinder electrode assembly with a plating surface and an electrical contact. The assembly is placed within a plating bath and rotated while running a plating cycle. Nickel-cobalt alloy deposition is selectively controlled by controlling current density distribution and/or cobalt content in the plating bath while running the plating cycle to deposit an alloy of a desired yield strength onto the plating surface in a single plating cycle. In various embodiments, the rotating cylinder may be used as an insitu monitoring method to assist in obtaining the properties desired.
Yeboah-afari, A
1993-01-01
In Danchira village in Ghana for the last 5 years, women and children rise before dawn every day to fetch water from a tributary or the River Densu, which is 5 miles from the village. Diminished rainfall has dried the village's 3 ponds and bore-hole where the women and children used to fetch water. To exacerbate the water problem, the Ghana Water and Sewerage Corporation no longer comes to fill the huge water tank it brought to Danchira when water scarcity first occurred. The villagers could not afford to pay for the water. A 55-year-old mother of 5, Dede Aryehteye, takes her morning bath at the river. When she has dirty laundry, she cleans it in the river. She returns to the village around 8 am. She uses the next hour to filter the dark water 2 times with a device provided free of charge by the national Guinea Worm Eradication Programme to keep the larvae out of the water. Next she sort the water for 3 uses: drinking, household use, and evening bath. Dede then does other domestic chores. She would rather go to her cassava farm in the early morning when it is cool but has to fetch water instead. When she is not too tired and after finishing domestic chores, she goes to the farm. Water-fetching also exhausts the children and gets them to school rather late. Children make up the majority of the 500 people living in Danchira. Water scarcity forced most of the young villagers to flee to the cities. For example, Dede's 4 older children now live in Accra. The water scarcity keeps the farmers from growing maize, cassava, and vegetables.
Miranda, Renata Pinto Ribeiro; de Cássia Lopes Chaves, Érika; Silva Lima, Rogério; Braga, Cristiane Giffoni; Simões, Ivandira Anselmo Ribeiro; Fava, Silvana Maria Coelho Leite; Iunes, Denise Hollanda
2017-10-01
Simulation allows students to develop several skills during a bed bath that are difficult to teach only in traditional classroom lectures, such as problem-solving, student interactions with the simulator (patient), reasoning in clinical evaluations, evaluation of responses to interventions, teamwork, communication, security and privacy. This study aimed to evaluate the effectiveness of a simulated bed bath scenario on improving cognitive knowledge, practical performance and satisfaction among nursing students. Randomized controlled clinical trial. Nursing students that were in the fifth period from two educational institutions in Brazil. Nursing students (n=58). The data were collected using the assessments of cognitive knowledge, practical performance and satisfaction were made through a written test about bed baths, an Objective Structured Clinical Examination (OSCE) and a satisfaction questionnaire. We identified that the acquisition and assimilation of cognitive knowledge was significantly higher in the simulation group (p=0.001). The performance was similar in both groups regardless of the teaching strategy (p=0.435). At follow-up, the simulation group had significantly more satisfaction with the teaching method than the control group (p=0.007). The teaching strategy based on a simulated scenario of a bed bath proved to be effective for the acquisition of cognitive knowledge regarding bed baths in clinical practice and improved student satisfaction with the teaching process. Copyright © 2017 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Landgraf, J.; Kanitz, C.
2017-05-01
When a water drop falls on an oscillating soapy water surface it is observed that coalescence of the drop is inhibited because the drops are bouncing on the surface like on a trampoline. In our research we made experimental and theoretical investigations to an undeformable drop on a deformable bath. We described the vertical movement, predicted the critical bouncing threshold and also made experiments to the effects of an increased Weber number and the horizontal movement of the drop caused by a vertical movement.
Suay-Matallana, Ignacio
2016-07-01
This article considers how chemical analyses were employed not only to study and describe mineral waters, but also to promote new spas, and to reinforce the scientific authority of experts. Scientists, jointly with bath owners, visitors and local authorities, created a significant spa market by transforming rural spaces into social and economic sites. The paper analyses the role developed by the chemist Antonio Casares in the commodification of mineral water in mid-19(th) century Spain. His scientific publications and water analyses put a new economic value on some Spanish mineral waters and rural springs. First the paper explores the relationship between geographic factors, regulation, and spa development in 19(th) century Spain, and considers how scientific work improved the economy of some rural areas. Then the transformation of numerous country springs into spas, and the commodification of baths as places between science and leisure is examined. Finally the location of spas across the borders of medicine and chemistry is shown, together with the complex field operations required to study mineral waters. This paper reveals an intense circulation of knowledge between the field, laboratories and scientific publications, as well as the essential role developed by experts like Casares, who not only contributed to the study of rural springs but also to their economic transformation.
NASA Astrophysics Data System (ADS)
Harris, Margaret
2016-08-01
With its penchant for using centrifuges, water baths and other laboratory tools to whip up novel tastes and textures, modernist cuisine - also known as “molecular gastronomy” - has a reputation for complexity. In his book Molecular Gastronomy at Home, chef Jozef Youssef aims to change that.
Green Pharmacy & PharmEcovigilance: Prescribing and the Planet
Active pharmaceutical ingredients (APIs) are well documented as ubiquitous contaminants in the environment, especially in surface waters. Although their primary source is excretion and bathing, a secondary route by which many APIs enter the environment is disposal of unwanted, le...
75 FR 28850 - Office of Hazardous Materials Safety; Notice of Application for Special Permits
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-24
... comments is desired, include a self-addressed stamped postcard showing the special permit number. FOR... which have been subject to an automated pressure test on the line in lieu of the hot water bath test...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-21
... submitted in triplicate. If confirmation of receipt of comments is desired, include a self-addressed stamped..., marking, Company) Boston, MA. sale and use of certain aerosol containers subject to the hot water bath...
Vanden Heuvel, Amy; McDermott, Colleen; Pillsbury, Robert; Sandrin, Todd; Kinzelman, Julie; Ferguson, John; Sadowsky, Michael; Byappanahalli, Muruleedhara; Whitman, Richard; Kleinheinz, Gregory T
2010-01-01
A linkage between Cladophora mats and exceedances of recreational water quality criteria has been suggested, but not directly studied. This study investigates the spatial and temporal association between Escherichia coli concentrations within and near Cladophora mats at two northwestern Lake Michigan beaches in Door County, Wisconsin. Escherichia coli concentrations in water underlying mats were significantly greater than surrounding water (p < 0.001). Below mat E. coli increased as the stranded mats persisted at the beach swash zone. Water adjacent to Cladophora mats had lower E. coli concentrations, but surpassed EPA swimming criteria the majority of sampling days. A significant positive association was found between E. coli concentrations attached to Cladophora and in underlying water (p < 0.001). The attached E. coli likely acted as a reservoir for populating water underlying the mat. Fecal bacterial pathogens, however, could not be detected by microbiological culture methods either attached to mat biomass or in underlying water. Removal of Cladophora mats from beach areas may improve aesthetic and microbial water quality at affected beaches. These associations and potential natural growth of E. coli in bathing waters call into question the efficacy of using E. coli as a recreational water quality indicator of fecal contaminations.
Bliem, Rupert; Reischer, Georg; Linke, Rita; Farnleitner, Andreas; Kirschner, Alexander
2018-06-01
In recent years, global warming has led to a growing number of Vibrio cholerae infections in bathing water users in regions formerly unaffected by this pathogen. It is therefore of high importance to monitor V. cholerae in aquatic environments and to elucidate the main factors governing its prevalence and abundance. For this purpose, rapid and standardizable methods that can be performed by routine water laboratories are prerequisite. In this study, we applied a recently developed multiplex quantitative PCR (qPCR) strategy (i) to monitor the spatiotemporal variability of V. cholerae abundance in two small soda pools and a large lake that is intensively used for recreation and (ii) to elucidate the main factors driving V. cholerae dynamics in these environments. V. cholerae was detected with qPCR at high concentrations of up to 970,000 genomic units 100 ml -1 during the warm season, up to 2 orders of magnitude higher than values obtained by cultivation. An independent cytometric approach led to results comparable to qPCR data but with significantly more positive samples due to problems with DNA recovery for qPCR. Not a single sample was positive for toxigenic V. cholerae , indicating that only nontoxigenic V. cholerae (NTVC) was present. Temperature was the main predictor of NTVC abundance, but the quality and quantity of dissolved organic matter were also important environmental correlates. Based on this study, we recommend using the developed qPCR strategy for quantification of toxigenic and nontoxigenic V. cholerae in bathing waters with the need for improvements in DNA recovery. IMPORTANCE There is a definitive need for rapid and standardizable methods to quantify waterborne bacterial pathogens. Such methods have to be thoroughly tested for their applicability to environmental samples. In this study, we critically tested a recently developed multiplex qPCR strategy for its applicability to determine the spatiotemporal variability of V. cholerae abundance in lakes with a challenging water matrix. Several qPCR protocols for V. cholerae detection have been developed in the laboratory, but comprehensive studies on the application to environmental samples are extremely scarce. In our study, we demonstrate that our developed qPCR approach is a valuable tool but that there is a need for improvement in DNA recovery for complex water matrices. Furthermore, we found that nontoxigenic V. cholerae is present in very high numbers in the investigated ecosystems, while toxigenic V. cholerae is apparently absent. Such information is of importance for public health. Copyright © 2018 American Society for Microbiology.
NASA Astrophysics Data System (ADS)
Thoren, K. M.; Sinigalliano, C. D.
2016-02-01
Despite numerous cases of beach bacteria affecting millions of people worldwide, the persistence of the bacteria populations in coastal areas is still not well understood. The purpose of this study was to test the levels of persistence of Fecal Indicating Bacteria (FIB) of enterococci, Escherichia coli, and Human-source Bacteroidales, within the intertidal "swash zone" and the deeper waist zone in which people commonly bathe and play. In addition, the study sought to determine if these bacterial contaminants may also be found in aerosols at the beach. Measuring solar insolation in relation to bacterial persistence in seaweed wrack was used to determine if sunlight plays a role in modifying concentrations of FIB at the beach. Light intensity measured by a solar photometer and air quality measured by aerosol plate counts and qPCR Microbial Source Tracking (MST) was compared to varying locations where the beach samples were collected. Results from water samples demonstrate that bacteria measured using plate counts and qPCR were indeed higher within the swash zone than in the waist zone. This is in contrast with the way that the EPA currently measures and determines the public safety of beach waters. They commonly measure the waist zone, but disregard the swash zone. Results from beach bio-aerosol samples showed a wide variety of fungi and bacteria in the beach air, and qPCR MST analysis of these bio-aerosols showed the presence of FIBs such as enterococci on several of the aerosol collection plates. This emphasizes the need to collect samples from the entire beach instead of just measuring at an isolated area, and that exposure to microbial contaminants may include bathing water, beach sand, seaweed wrack, and bio-aerosols. Thus, the data reveals a potential way to identify harmful levels of bacteria and dangerous levels of poor air quality at recreational beaches. These results expound the need for broader assessment of potential beach contamination, not only the swimming water, but also the beach air, shoreline, and also varying depths of water, which can be extremely beneficial to reduce people's risk from microbial contamination exposure.
Basire, Marie; Borgis, Daniel; Vuilleumier, Rodolphe
2013-08-14
Langevin dynamics coupled to a quantum thermal bath (QTB) allows for the inclusion of vibrational quantum effects in molecular dynamics simulations at virtually no additional computer cost. We investigate here the ability of the QTB method to reproduce the quantum Wigner distribution of a variety of model potentials, designed to assess the performances and limits of the method. We further compute the infrared spectrum of a multidimensional model of proton transfer in the gas phase and in solution, using classical trajectories sampled initially from the Wigner distribution. It is shown that for this type of system involving large anharmonicities and strong nonlinear coupling to the environment, the quantum thermal bath is able to sample the Wigner distribution satisfactorily and to account for both zero point energy and tunneling effects. It leads to quantum time correlation functions having the correct short-time behavior, and the correct associated spectral frequencies, but that are slightly too overdamped. This is attributed to the classical propagation approximation rather than the generation of the quantized initial conditions themselves.
ZnO/CdS bi-layer nanostructures photoelectrode for dye-sensitized solar cells
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dalal, Paresh V., E-mail: paresh10dalal@gmail.com; Deshpande, Milind P., E-mail: vishwadeshpande@yahoo.co.in; Solanki, Bharat G., E-mail: bhrt.solanki17@gmail.com
2016-05-06
Simple chemical deposition method for the synthesis of ZnO/CdS bilayer photoelectrode on fluorine doped tin oxide (FTO) coated glass substrate in aqueous medium at low temperature (< 373K) is described. The different preparative parameters such as deposition time, bath temperature, concentration of precursor solution and, pH of the bath etc. were optimized. Nanograined ZnO was deposited on FTO coated glass substrates by dip-coating method, whereas CdS nanorods were successfully synthesized on pre-deposited ZnO film by Chemical Bath Deposition (CBD) method. The Photovoltaic properties of FTO/ZnO/CdS bilayer photo electrodes were also studied. A maximum short circuit current density of 9.1 mA cm-2more » and conversion efficiency 1.05% are observed for ZnO/CdS-10min. Layer, which supports fast electron injection kinetics due to hetero structured nanorod, while minimum values of 0.53mA cm-2 and 0.01% respectively are observed for only ZnO deposited layer.« less
Kulthanan, Kanokvalai; Varothai, Supenya
2013-01-01
Background Patients with atopic dermatitis (AD) have increased susceptibility to irritants. Some patients have questions about types of water for bathing or skin cleansing. Objective We studied the pH of water from various sources to give an overview for physicians to recommend patients with AD. Methods Water from various sources was collected for measurement of the pH using a pH meter and pH-indicator strips. Results Bottled drinking still water had pH between 6.9 and 7.5 while the sparkling type had pH between 4.9 and 5.5. Water derived from home water filters had an approximate pH of 7.5 as same as tap water. Swimming pool water had had pH between 7.2 and 7.5 while seawater had a pH of 8. Normal saline and distilled water had pH of 5.4 and 5.7, respectively. Facial mineral water had pH between 7.5 and 8, while facial makeup removing water had an acidic pH. Conclusion Normal saline, distilled water, bottled sparkling water and facial makeup removing water had similar pH to that of normal skin of normal people. However, other factors including benefits of mineral substances in the water in terms of bacteriostatic and anti-inflammation should be considered in the selection of cleansing water. PMID:23956962
The Epidemiology of Weil's Disease
Alston, J. M.; Brown, H. C.
1937-01-01
Adolf Weil defined the disease as a clinical entity in 1886, and Leptospira ictero-hæmorrhagiæ was found to be the causative organism in 1915 by Inada et al. in Japan, and confirmed by Hübener and Reiter in Germany. The infection has been found in most countries, and recently there has been a great increase in the number of instances reported. In most parts of the world rats and other small rodents harbour the organism and excrete it in the urine. This is almost always the direct or indirect source of infection of man, but natural infection of dogs and foxes takes place, and is at least a potential danger to human beings. Infection is usually related to occupation in coal-mines, field work of all sorts, sewers, fish-cleaning, and to bathing in fresh water. The organism quickly dies in an acid medium, in strong sunlight and in salt water. These facts accord with the presence of the disease in certain situations. The route of infection of man is usually by contact of the abraded or sodden skin with infected mud or water, but it may be by inhalation of water and by bites of rats, dogs, and ferrets. Men are much more exposed to infection than women, but in fish-cleaners the incidence is equal in the sexes. Children are sometimes infected by bathing and in houses. The incubation time may be four to nineteen days, and is usually seven to thirteen days. By serological methods many unjaundiced and subclinical infections can be detected among people who are often at risk, and these correct the rather high fatality rates which are derived from jaundiced cases only. During the last three and a half years 142 authenticated instances of the disease in an obvious clinical form have been reported in the British Isles. Twenty-one occupations or circumstances were involved, and the case fatality rate was 15 per cent. ImagesFig. 1Fig. 2Fig. 3 PMID:19991094
A Rapid and Low-Cost PCR Thermal Cycler for Low Resource Settings.
Wong, Grace; Wong, Isaac; Chan, Kamfai; Hsieh, Yicheng; Wong, Season
2015-01-01
Many modern molecular diagnostic assays targeting nucleic acids are typically confined to developed countries or to the national reference laboratories of developing-world countries. The ability to make technologies for the rapid diagnosis of infectious diseases broadly available in a portable, low-cost format would mark a revolutionary step forward in global health. Many molecular assays are also developed based on polymerase chain reactions (PCR), which require thermal cyclers that are relatively heavy (>20 pounds) and need continuous electrical power. The temperature ramping speed of most economical thermal cyclers are relatively slow (2 to 3 °C/s) so a polymerase chain reaction can take 1 to 2 hours. Most of all, these thermal cyclers are still too expensive ($2k to $4k) for low-resource setting uses. In this article, we demonstrate the development of a low-cost and rapid water bath based thermal cycler that does not require active temperature control or continuous power supply during PCR. This unit costs $130 to build using commercial off-the-shelf items. The use of two or three vacuum-insulated stainless-steel Thermos food jars containing heated water (for denaturation and annealing/extension steps) and a layer of oil on top of the water allow for significantly stabilized temperatures for PCR to take place. Using an Arduino-based microcontroller, we automate the "archaic" method of hand-transferring PCR tubes between water baths. We demonstrate that this innovative unit can deliver high speed PCR (17 s per PCR cycle) with the potential to go beyond the 1,522 bp long amplicons tested in this study and can amplify from templates down to at least 20 copies per reaction. The unit also accepts regular PCR tubes and glass capillary tubes. The PCR efficiency of our thermal cycler is not different from other commercial thermal cyclers. When combined with a rapid nucleic acid detection approach, the thermos thermal cycler (TTC) can enable on-site molecular diagnostics in low-resource settings.
Does access to open water affect the health of Pekin ducks (Anas platyrhynchos)?
O'Driscoll, K K M; Broom, D M
2011-02-01
Access to open water is considered good for the welfare of Pekin ducks. These studies investigated the effect that the type of water resource, provided over either straw bedding or a rubber mesh, had on measures of duck health. Pekin strain ducklings (n = 2,600) were managed in pens of 100 on straw over a solid concrete floor. In study 1, one of two water resources (nipple, n = 5 pens; wide-lip bell drinker, n = 5 pens), was located directly over the straw. In study 2, one of three water resources (narrow-lip bell drinker, n = 6 pens; trough, n = 5 pens; and bath, n = 5 pens) was located over a rubber mesh. On d 16, 24, 29, 35, and 43, (study 1) or d 21, 29, 35, and 43 posthatch (study 2), 10 birds were selected from each pen and weighed, and then feather hygiene, footpad dermatitis, eye health, gait score, and nostril condition scores were taken. Treatment had no effect on BW in either study, but in study 2, ducks in the open water treatments had higher scores (P < 0.001) than those in the narrow-lip bell drinker treatment by d 43. In study 1, treatment had no effect on hygiene scores, but scores increased over time (P < 0.001). In study 2, ducks in the narrow-lip bell drinker treatment were dirtier than those in the bath treatment (P = 0.01), with those in the trough treatment being intermediate. In both studies, ducks with bell drinkers had worse gait scores than those in the other treatments (study 1, P < 0.01; study 2, P < 0.05). Treatment had no effect on eye health scores. However, ducks were less likely to have dirty nostrils when provided with more open water resources in both studies (P < 0.01), or were less likely to have blocked nostrils in the trough and bath treatments than in the narrow-lip bell drinker treatment in study 2 (P = 0.01). Provision of open water, particularly over a properly constructed drainage area, improved some aspects of duck health (improved feather hygiene and BW, and fewer dirty and blocked nostrils). However, further work is needed to investigate these treatments on a commercial scale.
Brack, Paul; Dann, Sandie; Wijayantha, K. G. Upul; Adcock, Paul; Foster, Simon
2016-01-01
There is a growing research interest in the development of portable systems which can deliver hydrogen on-demand to proton exchange membrane (PEM) hydrogen fuel cells. Researchers seeking to develop such systems require a method of measuring the generated hydrogen. Herein, we describe a simple, low-cost, and robust method to measure the hydrogen generated from the reaction of solids with aqueous solutions. The reactions are conducted in a conventional one-necked round-bottomed flask placed in a temperature controlled water bath. The hydrogen generated from the reaction in the flask is channeled through tubing into a water-filled inverted measuring cylinder. The water displaced from the measuring cylinder by the incoming gas is diverted into a beaker on a balance. The balance is connected to a computer, and the change in the mass reading of the balance over time is recorded using data collection and spreadsheet software programs. The data can then be approximately corrected for water vapor using the method described herein, and parameters such as the total hydrogen yield, the hydrogen generation rate, and the induction period can also be deduced. The size of the measuring cylinder and the resolution of the balance can be changed to adapt the setup to different hydrogen volumes and flow rates. PMID:27584581
Code of Federal Regulations, 2010 CFR
2010-07-01
...) Showers shall be provided with both hot and cold water. (ii) At least one shower head shall be provided... urinal. (iv) An adequate supply of toilet paper shall be provided with each toilet. (v) Adequate...
Code of Federal Regulations, 2014 CFR
2014-07-01
...) Showers shall be provided with both hot and cold water. (ii) At least one shower head shall be provided... urinal. (iv) An adequate supply of toilet paper shall be provided with each toilet. (v) Adequate...
Code of Federal Regulations, 2012 CFR
2012-07-01
...) Showers shall be provided with both hot and cold water. (ii) At least one shower head shall be provided... urinal. (iv) An adequate supply of toilet paper shall be provided with each toilet. (v) Adequate...
Code of Federal Regulations, 2013 CFR
2013-07-01
...) Showers shall be provided with both hot and cold water. (ii) At least one shower head shall be provided... urinal. (iv) An adequate supply of toilet paper shall be provided with each toilet. (v) Adequate...
Code of Federal Regulations, 2011 CFR
2011-07-01
...) Showers shall be provided with both hot and cold water. (ii) At least one shower head shall be provided... urinal. (iv) An adequate supply of toilet paper shall be provided with each toilet. (v) Adequate...
KENTUCKY STRAIGHT PIPES REPORT, DECEMBER 2002
The poor sanitary conditions and water pollution problems EPA observed in the Kentucky counties of Harlan, Martin, Bath, and Montgomery were of the highest concern. The widespread scale of both the straight pipe issues as well as package plant wastewater problems present an envir...
RELATIONSHIP OF MICROBIAL INDICATORS TO HEALTH EFFECTS AT MARINE BATHING BEACHES
Finds are described from the second year of an epidemiological-microbiological study conducted at New York City beaches as part of the U.S. Environmental Protection Agency program to develop health effects-recreational water quality criteria. Symptomatology rates among swimmers (...
2007-03-01
standards. As such, the reservoir is to be maintained suitable for drinking, culinary , and food processing purposes, after conventional treatment; bathing...to the Montana/North Dakota state line. Both B-2 and B-3 waters are to be maintained suitable for drinking, culinary and food processing purposes...QUAL-W2 is a “state-of-the- art ” water quality model that can greatly facilitate addressing reservoir water quality management issues. CE-QUAL-W2 is a
Crowther, J; Kay, D; Wyer, M D
2001-12-01
This paper explores ways in which the analysis of microbial data from routine compliance monitoring, in combination with basic environmental data, can provide insight into the factors affecting faecal-indicator organism concentrations in coastal waters. In the case study presented, eight designated bathing waters on the Fylde coast are continuing to exhibit unreliable compliance with the Imperative standards for total coliform (TC) and faecal coliform (FC) concentrations specified in the EU Bathing Water Directive (76/160/EEC), despite significant reductions in geometric mean concentrations following recent major investment in the sewerage infrastructure. Faecal streptococci (FS) concentrations have remained high and have not been improved by the new sewerage schemes. The results suggest that, prior to the schemes, higher bacterial concentrations were strongly associated with rainfall; and sewage sources were important for TC and FC, but less important for FS, which may have been more strongly affected by diffuse catchment sources. In the post-schemes period, catchment sources appear to be of greater significance; rainfall remains as a significant, though less important, predictor; and tide height at time of sampling, together with variables such as sunshine and the proportion of onshore winds (which affect the survival and movement of bacteria that have already entered the coastal waters), assume greater significance. The approach used here provides a cost-effective management tool for the exploratory investigation of any monitoring point that is failing to meet recreational water quality standards.
Poklis, Justin L; Wolf, Carl E; ElJordi, Omar I; Liu, Kai; Zhang, Shijun; Poklis, Alphonse
2015-01-01
In recent years, a large number of designer drugs sold as "Bath Salts" have appeared on the market. In July of 2011, Raving Dragon Novelty Bath Salts was obtained over the Internet. This product became unavailable in October of that year coinciding with the DEA issuing a temporarily schedule of mephedrone, methylone, and MDPV. Four months later in February of 2012, a new product was released from the same company under the new name Raving Dragon Voodoo Dust. The contents of both products were identified using spectroscopy methods: nuclear magnetic resonance, infrared, UV-visible, tandem mass spectrometry, and high-resolution time-of-flight mass spectrometry. It was determined that Raving Dragon Novelty Bath Salts contained methylone. The replacement product Raving Dragon Voodoo Dust contained the unscheduled drug pentedrone. The Raving Dragon brand of products illustrates the rapid change of ingredients in these products to circumvent laws restricting availability, distribution, and use. © 2014 American Academy of Forensic Sciences.
Costa Dos Reis, Luciana; Vidal, Lorena; Canals, Antonio
2017-04-01
A fast, simple, economical, and environmentally friendly magnetic solid-phase extraction (MSPE) procedure has been developed to preconcentrate 2,4,6-trinitrotoluene (TNT) from water samples prior to determination by liquid chromatography-UV-Vis employing graphene oxide/Fe 3 O 4 nanocomposite as sorbent. The nanocomposite synthesis was investigated, and the MSPE was optimized by a multivariate approach. The optimum MSPE conditions were 40 mg of nanocomposite, 10 min of vortex extraction, 1 mL of acetonitrile as eluent, and 6 min of desorption in an ultrasonic bath. Under the optimized experimental conditions, the method was evaluated to obtain a preconcentration factor of 153. The linearity of the method was studied from 1 to 100 μg L -1 (N = 5), obtaining a correlation coefficient of 0.994. The relative standard deviation and limit of detection were found to be 12% (n = 6, 10 μg L -1 ) and 0.3 μg L -1 , respectively. The applicability of the method was investigated, analyzing three types of water samples (i.e., reservoir and drinking water and effluent wastewater) and recovery values ranged between 87 and 120% (50 μg L -1 spiking level), showing that the matrix had a negligible effect upon extraction. Finally, the semiquantitative Eco-Scale metrics confirmed the greenness of the developed method.
NASA Astrophysics Data System (ADS)
Lee, Sang Myung; Lee, Suk Kyu; Paik, Doo-Jin; Park, Joo Hyun
2017-04-01
The mechanism of iron dissolution and the effect of initial Fe content in a Zn bath on the dissolution rate of iron were investigated using a finger rotating method (FRM). When the initial iron content, [Fe]°, in the zinc bath was less than the solubility limit, the iron content in the zinc bath showed a rapid increase, whereas a moderate increase was observed when [Fe]° was close to the solubility limit. Based on Eisenberg's kinetic model, the mass transfer coefficient of iron in the present experimental condition was calculated to be k M = 1.2 × 10-5 m/s, which was similar to the results derived by Giorgi et al. under industrial practice conditions. A dissolution of iron occurred even when the initial iron content in the zinc bath was greater than the solubility limit, which was explained by the interfacial thermodynamics in conjunction with the morphology of the surface coating layer. By analyzing the diffraction patterns using TEM, the outermost dendritic-structured coating layer was confirmed as FeZn13 ( ζ). In order to satisfy the local equilibrium based on the Gibbs-Thomson equation, iron in the dendrite-structured phase spontaneously dissolved into the zinc bath, resulting in the enrichment of iron in front of the dendrite tip. Through the diffusion boundary layer in front of the dendritic-structured layer, dissolved Fe atoms diffused out and reacted with Zn and small amounts of Al, resulting in the formation of dross particles such as FeZn10Al x ( δ). It was experimentally confirmed that the smaller the difference between the initial iron content in the zinc bath and the iron solubility limit at a given temperature, the lower the number of formed dross particles.
Direct observation of hygiene in a Peruvian shantytown: not enough handwashing and too little water
Oswald, William E.; Hunter, Gabrielle C.; Lescano, Andres G.; Cabrera, Lilia; Leontsini, Elli; Pan, William K.; Soldan, Valerie Paz; Gilman, Robert H.
2014-01-01
Summary OBJECTIVE To document frequency of hygiene practices of mothers and children in a shantytown in Lima, Peru. METHODS Continuous monitoring over three 12-h sessions in households without in-house water connections to measure: (i) water and soap use of 32 mothers; (ii) frequency of interrupting faecal-hand contamination by washing; and (iii) the time until faecal-hand contamination became a possible transmission event. RESULTS During 1008 h of observation, 55% (65/119) of mothers’ and 69% (37/54) of children's faecal-hand contamination events were not followed within 15 min by handwashing or bathing. Nearly 40% (67/173) of faecal-hand contamination events became possible faecal-oral transmission events. There was no difference in the time-until-transmission between mothers and children (P = 0.43). Potential transmission of faecal material to food or mouth occurred in 64% of cases within 1 h of hand contamination. Mean water usage (6.5 l) was low compared to international disaster relief standards. CONCLUSIONS We observed low volumes of water usage, inadequate handwashing, and frequent opportunities for faecal contamination and possible transmission in this water-scarce community. PMID:19055623
Pasaoglu, Mehmet Emin; Guclu, Serkan; Koyuncu, Ismail
Polyethersulfone (PES)/polyacrylonitrile (PAN) membranes have been paid attention among membrane research subjects. However, very few studies are included in the literature. In our study, asymmetric ultrafiltration (UF) membranes were prepared from blends of PES/PAN with phase inversion method using water as coagulation bath. Polyvinylpyrrolidone (PVP) with Mw of 10,000 Da was used as pore former agent. N,N-dimethylformamide was used as solvent. The effects of different percentage of PVP and PES/PAN composition on morphology and water filtration properties were investigated. Membrane performances were examined using pure water and lake water filtration studies. Performances of pure water were less with the addition of PAN into the PES polymer casting solutions. However, long-term water filtration tests showed that PES/PAN blend membranes anti-fouling properties were much higher than the neat PES membranes. The contact angles of PES/PAN membranes were lower than neat PES membranes because of PAN addition in PES polymer casting solutions. Furthermore, it was found that PES/PAN blend UF membranes' dynamic mechanical analysis properties in terms of Young's modules were less than neat PES membrane because of decreasing amount of PES polymer.
Lv, Yu-Zhen; Li, Chao; Sun, Qian; Huang, Meng; Li, Cheng-Rong; Qi, Bo
2016-12-01
Dispersion stability of nanoparticles in the liquid media is of great importance to the utilization in practice. This study aims to investigate the effects of mechanical dispersion method on the dispersibility of functionalized TiO 2 nanoparticles in the transformer oil. Dispersion methods, including stirring, ultrasonic bath, and probe processes, were systematically tested to verify their versatility for preparing stable nanofluid. The test results reveal that the combination of ultrasonic bath process and stirring method has the best dispersion efficiency and the obtained nanofluid possesses the highest AC breakdown strength. Specifically, after aging for 168 h, the size of nanoparticles in the nanofluid prepared by the combination method has no obvious change, while those obtained by the other three paths are increased obviously.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1988-07-25
The Colbert Landfill NPL site is located about fifteen miles north of Spokane, Washington. Area ground water is contaminated with several volatile organic chemicals. The medium of most concern regarding potential health effects is the ground water. Potential exposure pathways include ingestion and inhalation of volatiles from contaminated ground water and dermal exposure to contaminated ground water. The susceptible populations are remedial workers performing well water sampling on-site and populations off-site utilizing contaminated wells at levels that are of a potential health concern, for drinking, bathing, and irrigation purposes.
Wilson, Jolaine M; Bunte, Ralph M; Carty, Anthony J
2009-11-01
Despite the progressively increasing use of zebrafish (Danio rerio) in research, the most humane method of euthanasia for these fish has not been determined. Contemporary guidance documents state that hypothermia is an unacceptable method of euthanasia. The goal of this study was to compare rapid cooling and tricaine methanesulfonate (MS222) for zebrafish euthanasia. Zebrafish (n = 46) were euthanized by immersion in either an ice-water (4 degrees C or less) bath or unbuffered MS222 solution (250 mg/L; 25 to 30 degrees C). Another cohort (n = 10) was exposed to buffered MS222 to determine whether the acidity of the water alone caused distress. The times from exposure until the animals became unable to swim, right themselves, and death were measured, and signs of distress were recorded. Fish then were placed in a 'recovery tank' of system water to verify that recovery did not occur. Tissues were examined histologically. The mean time for euthanasia was longer and the number of fish exhibiting signs of distress was greater for fish exposed to MS222 than those exposed to chilled water. In addition, 4 of the 23 fish exposed to MS222 regained consciousness in the recovery tank, whereas none of 23 fish exposed to chilled water recovered. No histopathologic changes or evidence of ice crystal formation were seen in either group. In light of the faster time to death and fewer signs of distress in zebrafish euthanized by rapid cooling, we advocate this method as a humane veterinary practice.
González-Sálamo, Javier; González-Curbelo, Miguel Ángel; Socas-Rodríguez, Bárbara; Hernández-Borges, Javier; Rodríguez-Delgado, Miguel Ángel
2018-06-01
A new hollow fiber liquid-phase microextraction (HF-LPME) method has been developed for the extraction of a group of phthalic acid esters (PAEs) of interest from different water samples prior to gas chromatography tandem mass spectrometry analysis. HF-LPME was carried out using 1-octanol as extraction solvent followed by a back extraction step with cyclohexane. The different parameters that affect HF-LPME such as sample pH, ionic strength, extraction time, stirring rate, extraction temperature and back extraction conditions were investigated. The optimized conditions involved the extraction of 10 mL of sample without pH adjustment or addition of salt during 75 min under a stirring of 850 rpm at 60 °C and subsequent desorption with 200 μL of cyclohexane for 10 min in an ultrasonic bath. The method was validated in terms of calibration and recovery studies using dibutyl phthalate-d 4 as internal standard. The developed procedure gave satisfactory recovery (74-120%) and relative standard deviation values (<20%) for the studied PAEs in mineral, tap, pond and waste water samples. Copyright © 2018 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Meng, Wei; Virkar, Anil V.
1999-12-01
A number of mixed perovskites of the types Ba2B‧B″O6 (BaB‧1/2B″1/2O3) and Ba3B*B″2O9 (BaB*1/3B″2/3O3) where B‧=Gd, La, Nd, Sm, or Y; B″=Nb and B*=Ca were synthesized by a conventional calcination process, as well as by the molten salt method. The former consists of calcining appropriate mixtures of oxide or carbonate precursors in air at elevated temperatures (∼1250°C). The latter method consists of adding appropriate mixtures of oxide or carbonate precursors to a molten salt bath at relatively low temperatures (on the order of 300 to 500°C) so that the requisite compound is formed by dissolution-reprecipitation. X-ray diffraction confirmed the formation of a single-phase perovskite in each case with calcination at 1250°C. In a molten salt bath, however, all except Ba2LaNbO6 and Ba2NdNbO6 formed the perovskite structure. On the contrary, powders of Ba2LaNbO6 and Ba2NdNbO6 formed by a high-temperature calcination process readily decomposed when introduced into the molten salt bath. The formation of the requisite perovskite at a temperature as low as 350°C in a molten salt suggests that: (a) The perovskite is stable at 350°C. (b) The molten salt exhibits sufficient precursor solubility for the dissolution-reprecipitation process to occur in a reasonable time. Similarly, the decomposition of Ba2LaNbO6 and Ba2NdNbO6 in a molten salt bath shows that these materials are thermodynamically unstable at the temperature of the molten salt bath.
NEUTRONIC REACTOR WITH ACCESSIBLE THIMBLE AND EMERGENCY COOLING FEATURES
McCorkle, W.H.
1960-02-23
BS>A safety system for a water-moderated reactor is described. The invention comprises a reservoir system for spraying the fuel elements within a fuel assembly with coolant and keeping them in a continuous bath even if the coolant moderator is lost from the reactor vessel. A reservoir gravity feeds one or more nozzels positioned within each fuel assembly which continually forces water past the fuel elements.
7. INTERIOR VIEW OF THE MESTA CAROUSEL PICKLER, A SERIES ...
7. INTERIOR VIEW OF THE MESTA CAROUSEL PICKLER, A SERIES OF ACID, WATER AND LIME BATHS WHICH REMOVE RUST AND SCALE FROM THE STEEL PLATE AND LUBRICATES PLATE FOR THE SHEARING PROCESS - LaBelle Iron Works, Thirtieth & Wood Streets, Wheeling, Ohio County, WV
ERIC Educational Resources Information Center
Walker, Jearl
1984-01-01
Discusses the physics behind making ice cream in a hand-cranked ice cream maker. Ingredients in the maker are cooled and hardened by a bath of ice, water, and rock salt. Several experiments to investigate the variables involved in preparing the ice cream (and related desserts) are included. (JN)
Staining human lymphocytes and onion root cell nuclei with madder root.
Cücer, N; Guler, N; Demirtas, H; Imamoğlu, N
2005-01-01
We performed staining experiments on cells using natural dyes and different mordants using techniques that are used for wool and silk dyeing. The natural dye sources were madder root, daisy, corn cockle and yellow weed. Ferrous sulfate, copper sulfate, potassium tartrate, urea, potassium aluminum sulfate and potassium dichromate were used as mordants. Distilled water, distilled water plus ethanol, heptane, and distilled water plus methanol were used as solvents. All dye-mordant-solvent combinations were studied at pH 2.4, 3.2 and 4.2. The generic staining procedure was to boil 5-10 onion roots or stimulated human lymphocyte (SHL) preparations in a dye bath on a hot plate. Cells were examined at every half hour. For multicolor staining, madder-dyed lymphocytes were decolorized, then stained with Giemsa. The AgNOR technique was performed following the decolorization of Giemsa stained lymphocytes. Good results were obtained for both onion root cells and lymphocytes that were boiled for 3 h in a dye bath that included 4 g madder root, 4 g ferrous sulfate as mordant in 50 ml of 1:1 (v/v) methanol:distilled water. The pH was adjusted to 4.2 with 6 ml acetic acid. We conclude that madder root has potential as an alternative dye for staining biological materials.
Reduced oxygenation at intermediate depths of the southwest Pacific during the last glacial maximum
NASA Astrophysics Data System (ADS)
Durand, Axel; Chase, Zanna; Noble, Taryn L.; Bostock, Helen; Jaccard, Samuel L.; Townsend, Ashley T.; Bindoff, Nathaniel L.; Neil, Helen; Jacobsen, Geraldine
2018-06-01
To investigate changes in oxygenation at intermediate depths in the southwest Pacific between the Last Glacial Maximum (LGM) and the Holocene, redox sensitive elements uranium and rhenium were measured in 12 sediment cores located on the Campbell and Challenger plateaux offshore from New Zealand. The core sites are currently bathed by Subantarctic Mode Water (SAMW), Antarctic Intermediate Water (AAIW) and Upper Circumpolar Deep Water (UCDW). The sedimentary distributions of authigenic uranium and rhenium reveal reduced oxygen content at intermediate depths (800-1500 m) during the LGM compared to the Holocene. In contrast, data from deeper waters (≥1500 m) indicate higher oxygen content during the LGM compared to the Holocene. These data, together with variations in benthic foraminiferal δ13C, are consistent with a shallower AAIW-UCDW boundary over the Campbell Plateau during the LGM. Whilst AAIW continued to bathe the intermediate depths (≤1500 m) of the Challenger Plateau during the LGM, the data suggest that the AAIW at these core sites contained less oxygen compared to the Holocene. These results are at odds with the general notion that AAIW was better oxygenated and expanded deeper during the LGM due to stronger westerlies and colder temperatures. These findings may be explained by an important change in AAIW formation and circulation.
Jutte, Lisa S; Long, Blaine C; Knight, Kenneth L
2010-01-01
Thermocouples' leads are often too short, necessitating the use of an extension lead. To determine if temperature measures were influenced by extension-lead use or lead temperature changes. Descriptive laboratory study. Laboratory. Experiment 1: 10 IT-21 thermocouples and 5 extension leads. Experiment 2: 5 IT-21 and PT-6 thermocouples. In experiment 1, temperature data were collected on 10 IT-21 thermocouples in a stable water bath with and without extension leads. In experiment 2, temperature data were collected on 5 IT-21 and PT-6 thermocouples in a stable water bath before, during, and after ice-pack application to extension leads. In experiment 1, extension leads did not influence IT-21 validity (P = .45) or reliability (P = .10). In experiment 2, postapplication IT-21 temperatures were greater than preapplication and application measures (P < .05). Extension leads had no influence on temperature measures. Ice application to leads may increase measurement error.
Teraki, Yuichi; Nakamura, Kaori
2015-01-01
Pseudomonas folliculitis (PF) is a community-acquired skin infection, which develops after exposure to contaminated water such as whirlpools, swimming pools, water slides and hot tubs. In Japan, this condition has been sporadically reported, often in association with bathing; however, the exact cause of PF in the Japanese population remains unclear. In this study, we retrospectively reviewed 10 patients with PF diagnosed at our dermatology clinic (two males and eight females). Four patients had recurrences over 1-3 years. Notably, eight of the 10 patients were rubbing their bodies with nylon towels or sponges placed in the bathrooms during bathing. Pseudomonas aeruginosa was isolated from the nylon towels used in two of the two patients examined. Discontinued use of nylon towels resulted in prompt resolution of PF and no recurrence in all cases. Our observation suggests that rubbing the skin with nylon towels contaminated with P. aeruginosa was a major cause of PF in a Japanese population. © 2014 Japanese Dermatological Association.
Balsari, Satchit; Greenough, P Gregg; Kazi, Dhruv; Heerboth, Aaron; Dwivedi, Shraddha; Leaning, Jennifer
2016-12-01
India's Kumbh Mela remains the world's largest and longest mass gathering. The 2013 event, where participants undertook a ritual bath, hosted over 70 million Hindu pilgrims during 55 days on a 1936 hectare flood plain at the confluence of the Yamuna and Ganga Rivers. On the holiest bathing days, the population surged. Unlike other religious, cultural, and sports mass gatherings, the Kumbh Mela's administration cannot estimate or limit the participant number. The event created serious and uncommon public health challenges: initiating crowd safety measures where population density and mobility directly contact flowing bodies of water; providing water, sanitation, and hygiene to a population that frequently defecates in the open; and establishing disease surveillance and resource use measures within a temporary health delivery system. We review the world's largest gathering by observing first-hand the public health challenges, plus the preparations for and responses to them. We recommend ways to improve preparedness.