Sample records for water disinfecting desinfection

  1. The effect of disinfectant solutions on the hardness of acrylic resin denture teeth.

    PubMed

    Pavarina, A C; Vergani, C E; Machado, A L; Giampaolo, E T; Teraoka, M T

    2003-07-01

    This investigation studied the effects of disinfectant solutions on the hardness of acrylic resin denture teeth. The occlusal surfaces of 64 resin denture teeth were ground flat with abrasives up to 400-grit silicon carbide paper. Measurements were made after polishing and after the specimens were stored in water at 37 degrees C for 48 h. The specimens were then divided into four groups and immersed in chemical disinfectants (4% chlorhexidine; 1% sodium hypochlorite and sodium perborate) for 10 min. The disinfection methods were performed twice to simulate clinical conditions and hardness measurements were made. Specimens tested as controls were immersed in water during the same disinfection time. Eight specimens were produced for each group. After desinfection procedures, testing of hardness was also performed after the samples were stored at 37 degrees C for 7, 30, 60, 90 and 120 days. Data were analysed using two-way analysis of variance (anova) and Tukey's test at 95% confidence level. According to the results, no significant differences were found between materials and immersion solutions (P > 0.05). However, a continuous decrease in hardness was noticed after ageing (P < 0.05). It was conclude that the surfaces of both acrylic resin denture teeth softened upon immersion in water regardless the disinfecting solution.

  2. Water disinfection agents and disinfection by-products

    NASA Astrophysics Data System (ADS)

    Ilavský, J.; Barloková, D.; Kapusta, O.; Kunštek, M.

    2017-10-01

    The aim of this work is to describe factors of water quality change in the distribution network and legislative requirements in Slovakia for disinfectants and disinfection byproducts (DBPs). In the experimental part, the time dependence of the application of the chlorine dioxide and sodium hypochlorite on the formation of some by-products of disinfection for drinking water from WTP Hriňová is studied. We monitored trihalomethanes, free chlorine, chlorine dioxide and chlorites.

  3. Health effects of drinking water disinfectants and disinfection by-products

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Condie, L.W.; Bercz, J.P.

    This paper summarizes toxicological studies conducted with drinking water disinfectants. Toxicological effects, which are associated with the disinfectants themselves as well as with the by-products formed when disinfectants react with organic material present in water, are considered. The health impact of chemical reactions occurring between residual disinfectants and nutrients in the gastrointestinal tract is also discussed. 40 references, 5 tables.

  4. DISINFECTION OF NEW WATER MAINS

    EPA Science Inventory

    The 'AWWA Standard for Disinfecting Water Mains' (AWWA C601-68) has fallen into disuse by a number of water utilities because of repeated bacteriological failures following initial disinfection with the recommended high-dose chlorination. Other methods of disinfection, including ...

  5. Emergency Disinfection of Drinking Water

    EPA Pesticide Factsheets

    How to boil and disinfect water to kill most disease-causing microorganisms during emergency situations where regular water service has been interrupted and local authorities recommend using only bottled water, boiled water, or disinfected water.

  6. Electrochemical alternatives for drinking water disinfection.

    PubMed

    Martínez-Huitle, Carlos A; Brillas, Enric

    2008-01-01

    Chlorination is the most common method worldwide for the disinfection of drinking water. However, the identification of potentially toxic products from this method has encouraged the development of alternative disinfection technologies. Among them, electrochemical disinfection has emerged as one of the more feasible alternatives to chlorination. This article reviews electrochemical systems that can contribute to drinking water disinfection and underscores the efficiency of recently developed diamond films in chlorine-free electrochemical systems.

  7. Review of water disinfection techniques

    NASA Technical Reports Server (NTRS)

    Colombo, Gerald V.; Sauer, Richard L.

    1987-01-01

    Throughout the history of manned space flight the supply of potable water to the astronauts has presented unique problems. Of particular concern has been the microbiological quality of the potable water. This has required the development of both preflight water system servicing procedures to disinfect the systems and inflight disinfectant addition and monitoring devices to ensure continuing microbiological control. The disinfectants successfully used to date have been aqueous chlorine or iodine. Because of special system limitations the use of iodine has been the most successful for inflight use and promises to be the agent most likely to be used in the future. Future spacecraft potable, hygiene, and experiment water systems will utilize recycled water. This will present special problems for water quality control. NASA is currently conducting research and development to solve these problems.

  8. Do prevailing XAD extraction methods used to generate extracts from disinfected water adequately link extract toxicology to disinfected water chemistry?

    EPA Science Inventory

    Motivation: It is common to use XAD resins to extract disinfection byproducts (DBPs) from disinfected water. The resulting extract is used in toxicological assays to study the effects of DBP mixtures and has been considered representative of the original disinfected water. Howeve...

  9. Silver disinfection in water distribution systems

    NASA Astrophysics Data System (ADS)

    Silvestry Rodriguez, Nadia

    Silver was evaluated as disinfectant to maintain water quality in water distribution system. It was used to inhibit growth of two opportunistic bacteria in planktonik form and in biofilm formation in Robbins devices with stainless steel and PVC surfaces. The results of this work show that silver is a potential secondary disinfectant to be used in water distribution systems.

  10. Proteobacteria become predominant during regrowth after water disinfection.

    PubMed

    Becerra-Castro, Cristina; Macedo, Gonçalo; Silva, Adrian M T; Manaia, Célia M; Nunes, Olga C

    2016-12-15

    Disinfection processes aim at reducing the number of viable cells through the generation of damages in different cellular structures and molecules. Since disinfection involves unspecific mechanisms, some microbial populations may be selected due to resilience to treatment and/or to high post-treatment fitness. In this study, the bacterial community composition of secondarily treated urban wastewater and of surface water collected in the intake area of a drinking water treatment plant was compared before and 3-days after disinfection with ultraviolet radiation, ozonation or photocatalytic ozonation. The aim was to assess the dynamics of the bacterial communities during regrowth after disinfection. In all the freshly collected samples, Proteobacteria and Bacteroidetes were the predominant phyla (40-50% and 20-30% of the reads, respectively). Surface water differed from wastewater mainly in the relative abundance of Actinobacteria (17% and <5% of the reads, respectively). After 3-days storage at light and room temperature, disinfected samples presented a shift of Gammaproteobacteria (from 8 to 10% to 33-65% of the reads) and Betaproteobacteria (from 14 to 20% to 31-37% of the reads), irrespective of the type of water and disinfection process used. Genera such as Pseudomonas, Acinetobacter or Rheinheimera presented a selective advantage after water disinfection. These variations were not observed in the non-disinfected controls. Given the ubiquity and genome plasticity of these bacteria, the results obtained suggest that disinfection processes may have implications on the microbiological quality of the disinfected water. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Disinfection of Contaminated Water by Using Solar Irradiation

    PubMed Central

    Caslake, Laurie F.; Connolly, Daniel J.; Menon, Vilas; Duncanson, Catriona M.; Rojas, Ricardo; Tavakoli, Javad

    2004-01-01

    Contaminated water causes an estimated 6 to 60 billion cases of gastrointestinal illness annually. The majority of these cases occur in rural areas of developing nations where the water supply remains polluted and adequate sanitation is unavailable. A portable, low-cost, and low-maintenance solar unit to disinfect unpotable water has been designed and tested. The solar disinfection unit was tested with both river water and partially processed water from two wastewater treatment plants. In less than 30 min in midday sunlight, the unit eradicated more than 4 log10 U (99.99%) of bacteria contained in highly contaminated water samples. The solar disinfection unit has been field tested by Centro Panamericano de Ingenieria Sanitaria y Ciencias del Ambiente in Lima, Peru. At moderate light intensity, the solar disinfection unit was capable of reducing the bacterial load in a controlled contaminated water sample by 4 log10 U and disinfected approximately 1 liter of water in 30 min. PMID:14766599

  12. Disinfection of contaminated water by using solar irradiation.

    PubMed

    Caslake, Laurie F; Connolly, Daniel J; Menon, Vilas; Duncanson, Catriona M; Rojas, Ricardo; Tavakoli, Javad

    2004-02-01

    Contaminated water causes an estimated 6 to 60 billion cases of gastrointestinal illness annually. The majority of these cases occur in rural areas of developing nations where the water supply remains polluted and adequate sanitation is unavailable. A portable, low-cost, and low-maintenance solar unit to disinfect unpotable water has been designed and tested. The solar disinfection unit was tested with both river water and partially processed water from two wastewater treatment plants. In less than 30 min in midday sunlight, the unit eradicated more than 4 log10 U (99.99%) of bacteria contained in highly contaminated water samples. The solar disinfection unit has been field tested by Centro Panamericano de Ingenieria Sanitaria y Ciencias del Ambiente in Lima, Peru. At moderate light intensity, the solar disinfection unit was capable of reducing the bacterial load in a controlled contaminated water sample by 4 log10 U and disinfected approximately 1 liter of water in 30 min.

  13. Recent advances in drinking water disinfection: successes and challenges.

    PubMed

    Ngwenya, Nonhlanhla; Ncube, Esper J; Parsons, James

    2013-01-01

    Drinking water is the most important single source of human exposure to gastroenteric diseases, mainly as a result of the ingestion of microbial contaminated water. Waterborne microbial agents that pose a health risk to humans include enteropathogenic bacteria, viruses, and protozoa. Therefore, properly assessing whether these hazardous agents enter drinking water supplies, and if they do, whether they are disinfected adequately, are undoubtedly aspects critical to protecting public health. As new pathogens emerge, monitoring for relevant indicator microorganisms (e.g., process microbial indicators, fecal indicators, and index and model organisms) is crucial to ensuring drinking water safety. Another crucially important step to maintaining public health is implementing Water Safety Plans (WSPs), as is recommended by the current WHO Guidelines for Drinking Water Quality. Good WSPs include creating health-based targets that aim to reduce microbial risks and adverse health effects to which a population is exposed through drinking water. The use of disinfectants to inactivate microbial pathogens in drinking water has played a central role in reducing the incidence of waterborne diseases and is considered to be among the most successful interventions for preserving and promoting public health. Chlorine-based disinfectants are the most commonly used disinfectants and are cheap and easy to use. Free chlorine is an effective disinfectant for bacteria and viruses; however, it is not always effective against C. parvum and G. lamblia. Another limitation of using chlorination is that it produces disinfection by-products (DBPs), which pose potential health risks of their own. Currently, most drinking water regulations aggressively address DBP problems in public water distribution systems. The DBPs of most concern include the trihalomethanes (THMs), the haloacetic acids (HAAs), bromate, and chlorite. However, in the latest edition of the WHO Guidelines for Drinking Water Quality

  14. UV disinfection in drinking water supplies.

    PubMed

    Hoyer, O

    2000-01-01

    UV disinfection has become a practical and safely validatable disinfection procedure by specifying the requirements for testing and monitoring in DVGW standard W 294. A standardized biodosimetric testing procedure and monitoring with standardized UV sensors is introduced and successfully applied. On-line monitoring of irradiance can be counterchecked with handheld reference sensors and makes it possible that UV systems can be used for drinking water disinfection with the same level of confidence and safety as is conventional chemical disinfection.

  15. Basic Information about Chloramines and Drinking Water Disinfection

    EPA Pesticide Factsheets

    Chloramines are disinfectants used to treat drinking water. Chloramines are most commonly formed when ammonia is added to chlorine to treat drinking water. Chloramines provide longer-lasting disinfection as the water moves through pipes to consumers.

  16. Intracellular mechanisms of solar water disinfection

    NASA Astrophysics Data System (ADS)

    Castro-Alférez, María; Polo-López, María Inmaculada; Fernández-Ibáñez, Pilar

    2016-12-01

    Solar water disinfection (SODIS) is a zero-cost intervention measure to disinfect drinking water in areas of poor access to improved water sources, used by more than 6 million people in the world. The bactericidal action of solar radiation in water has been widely proven, nevertheless the causes for this remain still unclear. Scientific literature points out that generation of reactive oxygen species (ROS) inside microorganisms promoted by solar light absorption is the main reason. For the first time, this work reports on the experimental measurement of accumulated intracellular ROS in E. coli during solar irradiation. For this experimental achievement, a modified protocol based on the fluorescent probe dichlorodihydrofluorescein diacetate (DCFH-DA), widely used for oxidative stress in eukaryotic cells, has been tested and validated for E. coli. Our results demonstrate that ROS and their accumulated oxidative damages at intracellular level are key in solar water disinfection.

  17. Intracellular mechanisms of solar water disinfection

    PubMed Central

    Castro-Alférez, María; Polo-López, María Inmaculada; Fernández-Ibáñez, Pilar

    2016-01-01

    Solar water disinfection (SODIS) is a zero-cost intervention measure to disinfect drinking water in areas of poor access to improved water sources, used by more than 6 million people in the world. The bactericidal action of solar radiation in water has been widely proven, nevertheless the causes for this remain still unclear. Scientific literature points out that generation of reactive oxygen species (ROS) inside microorganisms promoted by solar light absorption is the main reason. For the first time, this work reports on the experimental measurement of accumulated intracellular ROS in E. coli during solar irradiation. For this experimental achievement, a modified protocol based on the fluorescent probe dichlorodihydrofluorescein diacetate (DCFH-DA), widely used for oxidative stress in eukaryotic cells, has been tested and validated for E. coli. Our results demonstrate that ROS and their accumulated oxidative damages at intracellular level are key in solar water disinfection. PMID:27909341

  18. Intracellular mechanisms of solar water disinfection.

    PubMed

    Castro-Alférez, María; Polo-López, María Inmaculada; Fernández-Ibáñez, Pilar

    2016-12-02

    Solar water disinfection (SODIS) is a zero-cost intervention measure to disinfect drinking water in areas of poor access to improved water sources, used by more than 6 million people in the world. The bactericidal action of solar radiation in water has been widely proven, nevertheless the causes for this remain still unclear. Scientific literature points out that generation of reactive oxygen species (ROS) inside microorganisms promoted by solar light absorption is the main reason. For the first time, this work reports on the experimental measurement of accumulated intracellular ROS in E. coli during solar irradiation. For this experimental achievement, a modified protocol based on the fluorescent probe dichlorodihydrofluorescein diacetate (DCFH-DA), widely used for oxidative stress in eukaryotic cells, has been tested and validated for E. coli. Our results demonstrate that ROS and their accumulated oxidative damages at intracellular level are key in solar water disinfection.

  19. Studies on Disinfection By-Products and Drinking Water

    USGS Publications Warehouse

    Rostad, Colleen E.

    2007-01-01

    Drinking water is disinfected with chemicals to remove pathogens, such as Giardia and Cryptosproridium, and prevent waterborne diseases such as cholera and typhoid. During disinfection, by-products are formed at trace concentrations. Because some of these by-products are suspected carcinogens, drinking water utilities must maintain the effectiveness of the disinfection process while minimizing the formation of by-products.

  20. Impact of disinfection on drinking water biofilm bacterial community.

    PubMed

    Mi, Zilong; Dai, Yu; Xie, Shuguang; Chen, Chao; Zhang, Xiaojian

    2015-11-01

    Disinfectants are commonly applied to control the growth of microorganisms in drinking water distribution systems. However, the effect of disinfection on drinking water microbial community remains poorly understood. The present study investigated the impacts of different disinfectants (chlorine and chloramine) and dosages on biofilm bacterial community in bench-scale pipe section reactors. Illumina MiSeq sequencing illustrated that disinfection strategy could affect both bacterial diversity and community structure of drinking water biofilm. Proteobacteria tended to predominate in chloraminated drinking water biofilms, while Firmicutes in chlorinated and unchlorinated biofilms. The major proteobacterial groups were influenced by both disinfectant type and dosage. In addition, chloramination had a more profound impact on bacterial community than chlorination. Copyright © 2015. Published by Elsevier B.V.

  1. MUTAGENICITY OF DRINKING WATER FOLLOWING DISINFECTION

    EPA Science Inventory

    Many drinking water utilities in the USA are considering alternatives to chlorine for disinfection in order to comply with federal regulations regarding disinfection by-products. An evaluation is thus needed of the potential risks associated with the use of alternative disinfecta...

  2. Solar water disinfection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anderson, R.; Collier, R.

    Non-potable drinking water is a major problem for much of the world`s population. It has been estimated that from 15 to 20 million children under the age of 5 die from diarrheal conditions brought on by infected drinking water every year. This is equivalent to a fully-loaded DC-10 crashing every ten minutes of every day, 365 days a year. Heat is one of the most effective methods of disinfecting drinking water. Using conventional means of heating water (heating on an open-flamed stove) results in an extremely energy-intensive process. The main obstacle is that for areas of the world where potablemore » water is a problem, fuel supplies are either too expensive, not available, or the source of devastating environmental problems (deforestation). The apparatus described is a solar-powered water disinfection device that can overcome most if not all of the barriers that presently limit technological solutions to drinking water problems. It uses a parabolic trough solar concentrator with a receiver tube that is also a counterflow heat exchanger. The system is totally self-contained utilizing a photovoltaic-powered water pump, and a standard automotive thermostat for water flow control. The system is designed for simplicity, reliability and the incorporation of technology readily accessible in most areas of the world. Experiments at the Florida Solar Energy Center have demonstrated up to 2,500 liters of safe drinking water per day with 28 square meters of solar concentrator.« less

  3. Drinking Water Supply without Use of a Disinfectant

    NASA Astrophysics Data System (ADS)

    Rajnochova, Marketa; Tuhovcak, Ladislav; Rucka, Jan

    2018-02-01

    The paper focuses on the issue of drinking water supply without use of any disinfectants. Before the public water supply network operator begins to consider switching to operation without use of chemical disinfection, initial assessment should be made, whether or not the water supply system in question is suitable for this type of operation. The assessment is performed by applying the decision algorithm. The initial assessment is followed by another decision algorithm which serves for managing and controlling the process of switching to drinking water supply without use of a disinfectant. The paper also summarizes previous experience and knowledge of this way operated public water supply systems in the Czech Republic.

  4. DRINKING WATER DISINFECTION BY-PRODUCTS: WHAT IS KNOWN

    EPA Science Inventory

    Chlorine, ozone, chlorine dioxide, and chloramine are currently the major disinfectants being used to disinfect drinking water. Although the alternative disinfectants (ozone, chlorine dioxide, and chloramine) are increasing in popularity in the United States, chlorine is still us...

  5. Chlorine disinfection of grey water for reuse: effect of organics and particles.

    PubMed

    Winward, Gideon P; Avery, Lisa M; Stephenson, Tom; Jefferson, Bruce

    2008-01-01

    Adequate disinfection of grey water prior to reuse is important to prevent the potential transmission of disease-causing microorganisms. Chlorine is a widely utilised disinfectant and as such is a leading contender for disinfection of grey water intended for reuse. This study examined the impact of organics and particles on chlorine disinfection of grey water, measured by total coliform inactivation. The efficacy of disinfection was most closely linked with particle size. Larger particles shielded total coliforms from inactivation and disinfection efficacy decreased with increasing particle size. Blending to extract particle-associated coliforms (PACs) following chlorine disinfection revealed that up to 91% of total coliforms in chlorinated grey water were particle associated. The organic concentration of grey water affected chlorine demand but did not influence the disinfection resistance of total coliforms when a free chlorine residual was maintained. Implications for urban water reuse are discussed and it is recommended that grey water treatment systems target suspended solids removal to ensure removal of PACs prior to disinfection.

  6. MODELING DISINFECTANT RESIDUALS IN DRINKING-WATER STORAGE TANKS

    EPA Science Inventory

    The factors leading to the loss of disinfectant residual in well-mixed drinking-water storage tanks are studied. Equations relating disinfectant residual to the disinfectant's reation rate, the tank volume, and the fill and drain rates are presented. An analytical solution for ...

  7. Ultraviolet (UV) disinfection of grey water: particle size effects.

    PubMed

    Winward, G P; Avery, L M; Stephenson, T; Jefferson, B

    2008-02-01

    The impact of water quality on the ultraviolet (UV) disinfection of grey water was investigated with reference to urban water reuse. Direct UV disinfection of grey water did not meet the stringent California State Title 22 criteria for unrestricted urban water reuse due to the presence of particulate material ranging from < 1 to > or = 2000 microm in size. Grey water was manipulated by settling to produce fractions of varying particle size distributions and blending was employed post-disinfection to extract particle-associated coliforms (PACs). The efficacy of UV disinfection was found to be linked to the particle size of the grey water fractions. The larger particle size fractions with a mean particle size of 262 microm and above were observed to shield more coliforms from UV light than did the smaller particles with a mean particle size below 119 microm. Up to 70% of total coliforms in the larger particle size fractions were particle-associated following a UV dose (fluence) of 260 mJ.cm(-2) and would remain undetected by standard coliform enumeration techniques. Implications for urban water reuse are discussed and recommendations made for grey water treatment to ensure removal of particle-associated indicator bacteria and pathogens prior to UV disinfection.

  8. The Next Generation of Drinking Water Disinfection By-Products

    EPA Science Inventory

    The disinfection of drinking water has been rightly hailed as a public health triumph of the 20th century. Millions of people worldwide receive quality drinking water every day from their public water systems. However, chemical disinfection has also produced an unintended healt...

  9. Disinfection By-Products: Formation and Occurrence in Drinking Water

    EPA Science Inventory

    The disinfection of drinking water has been rightly hailed as a public health triumph of the twentieth century. Millions of people worldwide receive quality drinking water every day from their public water systems. However, chemical disinfection has also produced an unintended he...

  10. Survival of viral biowarfare agents in disinfected waters.

    PubMed

    Wade, Mary Margaret; Chambers, Amanda E; Insalaco, Joseph M; Zulich, Alan W

    2010-01-01

    Protecting civilian and military water supplies has received more attention since the United States began its war on terror in 2001. Both chlorine and bromine are used by branches of the U.S. military for disinfecting water supplies; however, limited data exists as to the effectiveness of these additives when used against viral biowarfare agents. The present study sought to evaluate the survival of selected viral biothreat agents in disinfected water. Disinfected water samples were spiked with vaccinia virus strain WR and Venezuelan equine encephalitis (VEE) virus strain TC-83 each separately to a final concentration of approximately 1 × 10(6) PFU/mL, and survival was assessed by plaque assay. Both viruses were inactivated by 1 mg/L free available chlorine (FAC) and 2mg/L total bromine within one hour. In conclusion, these results demonstrate that both chlorine and bromine are effective disinfectants against vaccinia virus and VEE strain TC-83 at the concentrations tested.

  11. Survival of Viral Biowarfare Agents in Disinfected Waters

    PubMed Central

    Wade, Mary Margaret; Chambers, Amanda E.; Insalaco, Joseph M.; Zulich, Alan W.

    2010-01-01

    Protecting civilian and military water supplies has received more attention since the United States began its war on terror in 2001. Both chlorine and bromine are used by branches of the U.S. military for disinfecting water supplies; however, limited data exists as to the effectiveness of these additives when used against viral biowarfare agents. The present study sought to evaluate the survival of selected viral biothreat agents in disinfected water. Disinfected water samples were spiked with vaccinia virus strain WR and Venezuelan equine encephalitis (VEE) virus strain TC-83 each separately to a final concentration of approximately 1 × 106 PFU/mL, and survival was assessed by plaque assay. Both viruses were inactivated by 1 mg/L free available chlorine (FAC) and 2mg/L total bromine within one hour. In conclusion, these results demonstrate that both chlorine and bromine are effective disinfectants against vaccinia virus and VEE strain TC-83 at the concentrations tested. PMID:21197430

  12. Ultraviolet disinfection of potable water

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wolfe, R.L.

    Because of upcoming surface and groundwater regulations regarding the control of microbiological and chemical contaminants, there is a need to evaluate the feasibility and effectiveness of ultraviolet (UV) radiation for primary disinfection of potable water supplies. Data is presented on microbicidal wavelengths of UV and distribution of energy output for low and medium-pressure arc lamps. Both systems were found to perform equally well for inactivating microorganisms, but each had distinct advantages in different applications. Approximate dosages for 90% inactivation of selected microorganisms by UV is presented in a table. Cost analysis for disinfection is presented in two tables as wellmore » as the advantages and disadvantages of UV disinfection. 38 refs.« less

  13. DISINFECTION OF WATER: DRINKING WATER, RECREATIONAL WATER, AND WASTEWATER

    EPA Science Inventory

    This chapter describes and categorizes the methodology used for disinfection of drinking water, recreational water and wastewater including wastewater sludges. It largely is a literature summary and references articles covering the years of 1939 through 1999, with a few reference...

  14. The disinfection of drinking water. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    The current status of theoretically possible methods for disinfecting drinking water is reviewed. The specific biocidal activity of each of the disinfectants is considered, as well as information (or lack of it) on the practical application and reliability of the methods.

  15. Ultraviolet (UV) Disinfection for Drinking Water Systems

    EPA Science Inventory

    UV disinfection is an effective process for inactivating many microbial pathogens in water with potential to serve as stand-alone treatment or in combination with other disinfectants. USEPA provided guidance on the validation of UV reactors nearly a decade ago. Since then, lesson...

  16. Effect of well disinfection on arsenic in ground water

    USGS Publications Warehouse

    Gotkowitz, M.; Ellickson, K.; Clary, A.; Bowman, G.; Standridge, J.; Sonzogni, W.

    2008-01-01

    Domestic water wells are routinely subjected to in situ chemical disinfection treatments to control nuisance or pathogenic bacteria. Most treatments are chlorine based and presumably cause strongly oxidizing conditions in the wellbore. Water resource managers in Wisconsin were concerned that such treatments might facilitate release of arsenic from sulfide minerals disseminated within a confined sandstone aquifer. To test this hypothesis, a well was subjected to four disinfection treatments over 9 months time. The first treatment consisted of routine pumping of the well without chemical disinfection; three subsequent treatments included chlorine disinfection and pumping. Pretreatment arsenic concentrations in well water ranged from 7.4 to 18 ??g/L. Elevated arsenic concentrations up to 57 ??g/L in the chemical treatment solutions purged from the well are attributed to the disintegration or dissolution of biofilms or scale. Following each of the four treatments, arsenic concentrations decreased to less than 10 ??g/L during a period of pumping. Arsenic concentrations generally returned to pretreatment levels under stagnant, nonpumping conditions imposed following each treatment. Populations of iron-oxidizing, heterotrophic, and sulfate-reducing bacteria decreased following chemical treatments but were never fully eradicated from the well. Strongly oxidizing conditions were induced by the chlorine-based disinfections, but the treatments did not result in sustained increases in well water arsenic. Results suggest that disruption of biofilm and mineral deposits in the well and the water distribution system in tandem with chlorine disinfection can improve water quality in this setting. ?? 2008 The Author(s).

  17. Selection criteria for water disinfection techniques in agricultural practices.

    PubMed

    Haute, Sam van; Sampers, Imca; Jacxsens, Liesbeth; Uyttendaele, Mieke

    2015-01-01

    This paper comprises a selection tool for water disinfection methods for fresh produce pre- and postharvest practices. A variety of water disinfection technologies is available on the market and no single technology is the best choice for all applications. It can be difficult for end users to choose the technology that is best fit for a specific application. Therefore, the different technologies were characterized in order to identify criteria that influence the suitability of a technology for pre- or postharvest applications. Introduced criteria were divided into three principal components: (i) criteria related to the technology and which relate to the disinfection efficiency, (ii) attention points for the management and proper operation, and (iii) necessities in order to sustain the operation with respect to the environment. The selection criteria may help the end user of the water disinfection technology to obtain a systematic insight into all relevant aspects to be considered for preliminary decision making on which technologies should be put to feasibility testing for water disinfection in pre- and postharvest practices of the fresh produce chain.

  18. OPTIMAL SCHEDULING OF BOOSTER DISINFECTION IN WATER DISTRIBUTION SYSTEMS

    EPA Science Inventory

    Booster disinfection is the addition of disinfectant at locations distributed throughout a water distribution system. Such a strategy can reduce the mass of disinfectant required to maintain a detectable residual at points of consumption in the distribution system, which may lea...

  19. IDENTIFICATION OF DISINFECTION BY-PRODUCTS IN SWIMMING POOL WATER

    EPA Science Inventory

    In order to kill harmful pathogens, swimming pool water is treated with a disinfectant, such as chlorine or ozone. One of the most commonly used disinfectants is stabilized chlorine (typically trichloro-S-triazinetrione). Trichloro-S-triazinetrione reacts in water to form one m...

  20. [Bacteriological evaluation of a procedure for disinfecting the Olympus GIF-D2 panendoscope].

    PubMed

    Ramírez Ramos, A; Domínguez, N; Makino, R; Barrera, C

    1980-01-01

    We have performed a total of 107 cultures from three critical areas of an Olympus Panendoscope Model GIF-D2 in order to evaluate bacteriologically cur system of desinfection of this endoscope. Samples were taken from the distal end, external surface and biopsy canal before and after an endoscopic examination was performed. The procedure of desinfection employed was as follows: washing of the distal end, external surface and biopsy canal with Hexaclorophel (Phisohex) diluted 50% with water and a second washing with tap water. In the middle of the study, we added a second washing of the biopsy canal with ten ml. of ether alcohol to allow for better drying. As a result of the present study we observed that in the distal end in 50% of the samples we encountered bacteria. Cultures of the external surface were positive in 20% of samples. The biopsy canal should be washed with ether alcohol to allow for complete drying, because when we did not use this method, Pseudomonas Aeruginosa was isolated. After this modification we did not isolate bacteria. The most frequent types of isolated bacteria were from the normal oropharyngeal flora. From the present study we can conclude that desinfection of the Panendespe with Hexaclorophen gives satisfactory results on the external surface of the endoscope. Biopsy canal requires additional washing with ether alcohol. However, both procedures do not assure a satisfactory desinfection of the distal end.

  1. Disinfection aboard cruise liners and naval units: formation of disinfection by-products using chlorine dioxide in different qualities of drinking water.

    PubMed

    Ufermann, Petra; Petersen, Hauke; Exner, Martin

    2011-12-01

    The world-wide deployment of cruise liners and naval units has caused an increased need for the disinfection of drinking water. The main cause for this is the unknown quality of drinking water in foreign harbours--besides the formation of bio-films due to the climatically disadvantageous conditions in the operational area. Water conduits on board are currently disinfected with calcium hypochlorite in case of microbiological contamination. Chemical and physical analyses after disinfection with calcium hypochlorite have shown that organic by-products consisting of trihalomethanes develop in considerable amounts during disinfection. Furthermore, the method is susceptible to handling errors and thus often leads to insufficient disinfection results. Hitherto, the use of other disinfection methods allowed by government regulations, especially chlorine dioxide, is not widely spread. Unlike disinfection with calcium hypochlorite, chlorine dioxide does not lead to the formation of trihalomethanes. Typical disinfection by-products (DBP) are the anions chlorite and chlorate, which are formed in oxidative processes. The formation conditions of these anions have not yet been elucidated. For this reason, the probability of the generation of inorganic by-products after disinfection with chlorine dioxide has been determined, and their occurrence in drinking water on board has been examined with respect to a possible correlation between water quality and the formation of chlorate and chlorite. Therefore, a chromatographic method was developed and validated in order to determine the periodical development of chlorate and chlorite from chorine dioxide in purified water at different pH-values as well as in actual drinking water samples from water conduits on board. The formation of the by-products chlorite and chlorate after disinfection with chlorine dioxide is influenced neither by pH-value nor by chemical properties of the disinfected water. Considering the examined conditions

  2. Factors affecting the water odor caused by chloramines during drinking water disinfection.

    PubMed

    Wang, An-Qi; Lin, Yi-Li; Xu, Bin; Hu, Chen-Yan; Gao, Ze-Chen; Liu, Zhi; Cao, Tong-Cheng; Gao, Nai-Yun

    2018-10-15

    Chloramine disinfection is one of the most common disinfection methods in drinking water treatment. In this study, the temporal variability of water odors during monochloramine auto-decomposition was investigated to elucidate the characteristics of odor problems caused by adopting chloramine disinfection in tap water. Odor intensities and dominant odorant contributions were determined using the flavor profile analysis (FPA) and odor active value (OAV), respectively. During auto-decomposition of monochloramine, Cl 2 /N molar ratio, pH, temperature, and the presence of NOM all affected odor intensity and odor temporal variation in drinking water. In general, decreasing pH from 8.5 to 6.0 led to increasing perceived odor intensity due to the formation of dichloramine. The major odorants responsible for chlorinous odor under acidic and non-acidic conditions were dichloramine and monochloramine, respectively. Chloraminated water with a Cl 2 /N molar ratio of 0.6 or NOM concentration <2 mg-C L -1 inhibited odor intensity. Furthermore, the influence of rechlorination on chlorinous odor intensity for chloraminated water should not be neglected. The results of this study will be beneficial for the control of chlorinous odors caused by chloramine disinfection in drinking water. Copyright © 2018 Elsevier B.V. All rights reserved.

  3. Solar disinfection of water for diarrhoeal prevention in southern India.

    PubMed

    Rose, A; Roy, S; Abraham, V; Holmgren, G; George, K; Balraj, V; Abraham, S; Muliyil, J; Joseph, A; Kang, G

    2006-02-01

    To evaluate the efficacy and acceptability of solar irradiation in the prevention of diarrhoeal morbidity in children under 5 years of age, in an urban slum in Vellore, Tamil Nadu. A total of 100 children were assigned to receive drinking water that had been subjected to solar disinfection in polyethylene terephthalate bottles. One hundred age and sex matched controls were also selected. Both groups were followed by weekly home visits for a period of six months for any diarrhoeal morbidity. At the end of the follow up period, the acceptability of the intervention was assessed by interviews, questionnaires, and focus group discussions. There was significant reduction in the incidence, duration, and severity of diarrhoea in children receiving solar disinfected water, despite 86% of the children drinking water other than that treated by the intervention. The incidence of diarrhoea in the intervention group was 1.7 per child-year, and among controls 2.7 per child-year, with an incidence rate ratio of 0.64 (95% CI -0.48 to 0.86). The risk of diarrhoea was reduced by 40% by using solar disinfection. In qualitative evaluation of acceptability, most women felt that solar disinfection was a feasible and sustainable method of disinfecting water. Solar disinfection of water is an inexpensive, effective, and acceptable method of increasing water safety in a resource limited environment, and can significantly decrease diarrhoeal morbidity in children.

  4. [Research development on disinfection technology for viruses in drinking water].

    PubMed

    Zhang, Yun; Zhang, Qiang; Liu, Yan; Dai, Ruihua; Liu, Xiang

    2010-09-01

    With the deterioration of water source pollution, the quality requirements for drinking water of countries will become stricter and stricter, and the microbe index has been one of the important aspects. The introduction of the virus index and the development of disinfection technology focusing on virus have significant importance for the improvement of the drinking water standards and for the protection of people health in every country. To be familiar with the domestic and abroad research development of the disinfection control technology focusing on virus provides certain theory guidance and technological support for continuously improving drinking water standard in our country and for establishing safer drinking water processing technologies. So, this article will comprehensively describes 4 aspects: resistance comparison of virus over every disinfection technology, influential factors of disinfection, research development of new technology, and the mechanisms.

  5. A review of heterogeneous photocatalysis for water and surface disinfection.

    PubMed

    Byrne, John Anthony; Dunlop, Patrick Stuart Morris; Hamilton, Jeremy William John; Fernández-Ibáñez, Pilar; Polo-López, Inmaculada; Sharma, Preetam Kumar; Vennard, Ashlene Sarah Margaret

    2015-03-30

    Photo-excitation of certain semiconductors can lead to the production of reactive oxygen species that can inactivate microorganisms. The mechanisms involved are reviewed, along with two important applications. The first is the use of photocatalysis to enhance the solar disinfection of water. It is estimated that 750 million people do not have accessed to an improved source for drinking and many more rely on sources that are not safe. If one can utilize photocatalysis to enhance the solar disinfection of water and provide an inexpensive, simple method of water disinfection, then it could help reduce the risk of waterborne disease. The second application is the use of photocatalytic coatings to combat healthcare associated infections. Two challenges are considered, i.e., the use of photocatalytic coatings to give "self-disinfecting" surfaces to reduce the risk of transmission of infection via environmental surfaces, and the use of photocatalytic coatings for the decontamination and disinfection of medical devices. In the final section, the development of novel photocatalytic materials for use in disinfection applications is reviewed, taking account of materials, developed for other photocatalytic applications, but which may be transferable for disinfection purposes.

  6. Sewage disinfection towards protection of drinking water resources.

    PubMed

    Kolch, A

    2000-01-01

    Wastewater applied in agriculture for irrigation could replace the use of natural drinking-water resources. With respect to high concentrations of human pathogens wastewater has to be disinfected prior to use. This paper introduces disinfection methods with emphasis on UV irradiation.

  7. Solar disinfection of water for diarrhoeal prevention in southern India

    PubMed Central

    Rose, A; Roy, S; Abraham, V; Holmgren, G; George, K; Balraj, V; Abraham, S; Muliyil, J; Joseph, A; Kang, G

    2006-01-01

    Aims To evaluate the efficacy and acceptability of solar irradiation in the prevention of diarrhoeal morbidity in children under 5 years of age, in an urban slum in Vellore, Tamil Nadu. Methods A total of 100 children were assigned to receive drinking water that had been subjected to solar disinfection in polyethylene terephthalate bottles. One hundred age and sex matched controls were also selected. Both groups were followed by weekly home visits for a period of six months for any diarrhoeal morbidity. At the end of the follow up period, the acceptability of the intervention was assessed by interviews, questionnaires, and focus group discussions. Results There was significant reduction in the incidence, duration, and severity of diarrhoea in children receiving solar disinfected water, despite 86% of the children drinking water other than that treated by the intervention. The incidence of diarrhoea in the intervention group was 1.7 per child‐year, and among controls 2.7 per child‐year, with an incidence rate ratio of 0.64 (95% CI −0.48 to 0.86). The risk of diarrhoea was reduced by 40% by using solar disinfection. In qualitative evaluation of acceptability, most women felt that solar disinfection was a feasible and sustainable method of disinfecting water. Conclusions Solar disinfection of water is an inexpensive, effective, and acceptable method of increasing water safety in a resource limited environment, and can significantly decrease diarrhoeal morbidity in children. PMID:16403847

  8. Water disinfection: microbes versus molecules - an introduction of issues

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fowle, J.R. III, Kopfler, F.C.

    If the chemicals used to rid drinking water of disease-causing microbes are themselves potentially harmful, is drinking water safe. What trade-offs are acceptable with respect to microbial versus chemical water quality. This conference deals with current thinking about these topics. The subjects discussed reflect the evolution of thinking, both scientifically and socially, about how best to supply the public with safe, pure potable water. The goal of this paper is to introduce the issues associated with disinfectants and disinfectant by-products in water. This will be done by presenting a historical overview of the use of chemical disinfectants to purify drinkingmore » water and the subsequent awareness of potential health concerns. Historically, the major health issue associated with water has been the demonstrated role that water has played in spreading infectious disease. Waterborne infectious agents remain in the environment, and new ones emerge through evolution of humans and microorganisms and because of changing exposure patterns.« less

  9. Toxic impact of bromide and iodide on drinking water disinfected with chlorine or chloramines.

    PubMed

    Yang, Yang; Komaki, Yukako; Kimura, Susana Y; Hu, Hong-Ying; Wagner, Elizabeth D; Mariñas, Benito J; Plewa, Michael J

    2014-10-21

    Disinfectants inactivate pathogens in source water; however, they also react with organic matter and bromide/iodide to form disinfection byproducts (DBPs). Although only a few DBP classes have been systematically analyzed for toxicity, iodinated and brominated DBPs tend to be the most toxic. The objectives of this research were (1) to determine if monochloramine (NH2Cl) disinfection generated drinking water with less toxicity than water disinfected with free chlorine (HOCl) and (2) to determine the impact of added bromide and iodide in conjunction with HOCl or NH2Cl disinfection on mammalian cell cytotoxicity and genomic DNA damage induction. Water disinfected with chlorine was less cytotoxic but more genotoxic than water disinfected with chloramine. For both disinfectants, the addition of Br(-) and I(-) increased cytotoxicity and genotoxicity with a greater response observed with NH2Cl disinfection. Both cytotoxicity and genotoxicity were highly correlated with TOBr and TOI. However, toxicity was weakly and inversely correlated with TOCl. Thus, the forcing agents for cytotoxicity and genotoxicity were the generation of brominated and iodinated DBPs rather than the formation of chlorinated DBPs. Disinfection practices need careful consideration especially when using source waters containing elevated bromide and iodide.

  10. MAMMALIAN CELL CYTOTOXICITY AND GENOTOXICITY OF NEW DRINKING WATER DISINFECTION BY-PRODUCTS

    EPA Science Inventory

    The disinfection of drinking water continues to protect the public health against acute disease. Drinking water disinfection by-products (DBPs) are formed by the reaction of a disinfectant with naturally occurring organic matter. Many DBPs are genotoxic and are implicated as huma...

  11. Recycled Water Poses Disinfectant Problem

    ERIC Educational Resources Information Center

    Chemical and Engineering News, 1973

    1973-01-01

    Discusses the possible health hazards resulting from released nucleic acid of inactivated viruses, chlorinated nonliving organic molecules, and overestimated reliability of waste treatment standards. Suggests the recycle system use a dual disinfectant such as chlorine and ozone in water treatment. (CC)

  12. Drinking Water Disinfection Byproducts (DBPs) and Human Health Effects: Multidisciplinary Challenges and Opportunities.

    PubMed

    Li, Xing-Fang; Mitch, William A

    2018-02-20

    While drinking water disinfection has effectively prevented waterborne diseases, an unintended consequence is the generation of disinfection byproducts (DBPs). Epidemiological studies have consistently observed an association between consumption of chlorinated drinking water with an increased risk of bladder cancer. Out of the >600 DBPs identified, regulations focus on a few classes, such as trihalomethanes (THMs), whose concentrations were hypothesized to correlate with the DBPs driving the toxicity of disinfected waters. However, the DBPs responsible for the bladder cancer association remain unclear. Utilities are switching away from a reliance on chlorination of pristine drinking water supplies to the application of new disinfectant combinations to waters impaired by wastewater effluents and algal blooms. In light of these changes in disinfection practice, this article discusses new approaches being taken by analytical chemists, engineers, toxicologists and epidemiologists to characterize the DBP classes driving disinfected water toxicity, and suggests that DBP exposure should be measured using other DBP classes in addition to THMs.

  13. Review of electrotechnologies used in the disinfection of water and wastewater

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    VandeVenter, L.W.

    This report provides an overview of the disinfection practices used in water and wastewater treatment. Chlorine historically has been the disinfectant of choice for both water and wastewater, but with increased research and more stringent regulations, other disinfectants, namely ozone and ultraviolet irradiation, are being considered. The report summarizes the present and future applications of these technologies and defines possible opportunities for Demand- Side Management (DSM).

  14. Ozone-initiated disinfection kinetics of Escherichia coli in water.

    PubMed

    Zuma, Favourite; Lin, Johnson; Jonnalagadda, Sreekanth B

    2009-01-01

    The effect of ozonation on the rate of disinfection of Escherichia coli was investigated as a function of ozone concentration, ozonation duration and flow rates. Ozone was generated in situ using Corona discharge method using compressed oxygen stream and depending on the oxygen flux the ozone concentrations ranged from 0.91-4.72 mg/L. The rate of disinfection of all the three microbes followed pseudo-first-order kinetics with respect to the microbe count and first order with respect to ozone concentration. The influence of pH and temperature the aqueous systems on the rate of ozone initiated disinfection of the microbe was investigated. The inactivation was faster at lower pH than at basic pH. Molecular ozone is found more effective in disinfection than hydroxyl radicals. Two reported mechanisms for antimicrobial activity of ozone in water systems from the literature are discussed. Based on the experimental findings a probable rate law and mechanism are proposed. Ozonation of natural waters significantly decreased the BOD levels of the control and microbe contaminated waters.

  15. Integrated Disinfection By-Products Mixtures Research: Disinfection of Drinking Waters by Chlorination and Ozonation/Postchlorination Treatment Scenarios

    EPA Science Inventory

    This article describes disinfection of the same source water by two commonly used disinfection treatment scenarios for purposes of subsequent concentration, chemical analysis, and toxicological evaluation. Accompanying articles in this issue of the Journal of Toxicology and Envir...

  16. Biological Treatment of Water Disinfection Byproducts using ...

    EPA Pesticide Factsheets

    Major disinfection by-products (DBPs) from the chlorination process of drinking water include trihalomethanes (THMs) and haloacetic acides (HAA5). THMs mainly consist of chloroform, and other harsh chemicals. Prolonged consumptions of drinking water containing high levels of THMs has been linked with diseases of the liver, kidneys, bladder, or central nervous system and may increase likelihood of cancer. A risk also exists for THMs exposure via inhalation while showering, bathing or washing clothes and dishes. Due to these risks, the U.S. EPA regulate THMs content in drinking water. This research investigates biological degradation of THM using chloroform as a model compound. The study aims to decrease possible risks of THMs through filtration. Throughout this year’s presentations, there is a common theme of health and safety concerns. UC researchers are working hard to clean water ways of naturally occurring contaminates as well as man-made toxins found in our waterways. The significance of these presentations translates into the promise of safer environments, and more importantly saved lives, as UC’s faculty continues to produce real-world solutions to problems threatening the world around us. A biotech process has been developed and demonstrated that effectively remove and treat volatile disinfection by-products from drinking water. The process strips low concentration disinfection by-products, such as trihalomethanes, that are formed during the chlori

  17. A pilot study of solar water disinfection in the wilderness setting.

    PubMed

    Tedeschi, Christopher M; Barsi, Christopher; Peterson, Shane E; Carey, Kevin M

    2014-09-01

    Solar disinfection of water has been shown to be an effective treatment method in the developing world, but not specifically in a wilderness or survival setting. The current study sought to evaluate the technique using materials typically available in a wilderness or backcountry environment. Untreated surface water from a stream in rural Costa Rica was disinfected using the solar disinfection (SODIS) method, using both standard containers as well as containers and materials more readily available to a wilderness traveler. Posttreatment samples using polyethylene terephthalate (PET) bottles, as well as Nalgene and Platypus water containers, showed similarly decreased levels of Escherichia coli and total coliforms. The SODIS technique may be applicable in the wilderness setting using tools commonly available in the backcountry. In this limited trial, specific types of containers common in wilderness settings demonstrated similar performance to the standard containers. With further study, solar disinfection in appropriate conditions may be included as a viable treatment option for wilderness water disinfection. Copyright © 2014 Wilderness Medical Society. Published by Elsevier Inc. All rights reserved.

  18. Occurrence and exposures to disinfectants and disinfection by-products

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cumming, R.B.; Jolley, R.L.

    1992-12-31

    Disinfection by-products are associated with all chemical disinfectants. The concentration and toxic nature of the disinfection byproducts (DBPs) is a direct function of the chemical nature of the disinfectant itself and/or of the chemical reactions of the disinfectant with reaction substrates in the water, especially organic constituents. A principal advantage of biological and physical water treatment processes, such as filtration, is the lack of chemical reactions producing disinfectant-related DBPs. The use of the highest quality source water available is important for minimization of DBP formation. In lieu of such high quality water, improvement of water quality by removal of DBPmore » precursors through filtration or other means before application of chemical disinfectants is important. Most, if not all, water treatment experts are aware of these simplistic axioms. In view of the increasing knowledge being developed concerning DBPs including the identification of ``new`` DBPs, prudence dictates minimization of DBP formation. Wholesome drinking water is perhaps the biggest economic bargain available to consumers. The cost-effectiveness of water quality improvement should be evaluated with that in mind.« less

  19. Occurrence and exposures to disinfectants and disinfection by-products

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cumming, R.B.; Jolley, R.L.

    1992-01-01

    Disinfection by-products are associated with all chemical disinfectants. The concentration and toxic nature of the disinfection byproducts (DBPs) is a direct function of the chemical nature of the disinfectant itself and/or of the chemical reactions of the disinfectant with reaction substrates in the water, especially organic constituents. A principal advantage of biological and physical water treatment processes, such as filtration, is the lack of chemical reactions producing disinfectant-related DBPs. The use of the highest quality source water available is important for minimization of DBP formation. In lieu of such high quality water, improvement of water quality by removal of DBPmore » precursors through filtration or other means before application of chemical disinfectants is important. Most, if not all, water treatment experts are aware of these simplistic axioms. In view of the increasing knowledge being developed concerning DBPs including the identification of new'' DBPs, prudence dictates minimization of DBP formation. Wholesome drinking water is perhaps the biggest economic bargain available to consumers. The cost-effectiveness of water quality improvement should be evaluated with that in mind.« less

  20. Nanowire-Modified Three-Dimensional Electrode Enabling Low-Voltage Electroporation for Water Disinfection.

    PubMed

    Huo, Zheng-Yang; Xie, Xing; Yu, Tong; Lu, Yun; Feng, Chao; Hu, Hong-Ying

    2016-07-19

    More than 10% of the people in the world still suffer from inadequate access to clean water. Traditional water disinfection methods (e.g., chlorination and ultraviolet radiation) include concerns about the formation of carcinogenic disinfection byproducts (DBPs), pathogen reactivation, and/or excessive energy consumption. Recently, a nanowire-assisted electroporation-disinfection method was introduced as an alternative. Here, we develop a new copper oxide nanowire (CuONW)-modified three-dimensional copper foam electrode using a facile thermal oxidation approach. An electroporation-disinfection cell (EDC) equipped with two such electrodes has achieved superior disinfection performance (>7 log removal and no detectable bacteria in the effluent). The disinfection mechanism of electroporation guarantees an exceedingly low operation voltage (1 V) and level of energy consumption (25 J L(-1)) with a short contact time (7 s). The low operation voltage avoids chlorine generation and thus reduces the potential of DBP formation. Because of irreversible electroporation damage on cell membranes, no regrowth and/or reactivation of bacteria occurs during storage after EDC treatment. Water disinfection using EDCs has great potential for practical applications.

  1. CHEMICAL AND BIOLOGICAL CHARACTERIZATION OF NEWLY DISCOVERED IODOACID DRINKING WATER DISINFECTION BYPRODUCTS

    EPA Science Inventory

    Iodoacid drinking water disinfection byproducts (DBPs) were recently uncovered in drinking water samples from source water with a high bromide/iodide concentration that was disinfected with chloramines. The purpose of this paper is to report the analytical chemical identification...

  2. Free Available Chlorine Disinfection Criteria for Fixed Army Installation Primary Drinking Water

    DTIC Science & Technology

    1981-12-01

    Buffered Water with Fuivic Acid (5 C.U.) at pH 9 and 60C ............................................ 6. FAC Disinfection of f 2 Coliphage in Buffered Water ...with and without 250 mg/L -Ca+ at pH 5, 7, and 9 and 6°C ............... 31 10. FAC Disinfection of f 2 Coliphage in Water Containing 5 NTU Bentonite2...rngi L Ca+ 2 at pH- 5, 7, and q and 60C ...... ........................ 34 13. FAC Disinfection of f 2 Coliphage in Borate-Buffered Water with 250 mg

  3. The Occurrence and Comparative Toxicity of Haloacetaldehyde Disinfection Byproducts in Drinking Water

    EPA Science Inventory

    The introduction of drinking water disinfection greatly reduced the incidence of waterborne diseases. However, the reaction between disinfectants and natural organic matter in the source water can lead to an unintended consequence, which is the formation of drinking water disinfe...

  4. Chloramination of Concentrated Drinking Water for Disinfection Byproduct Mixtures Creation- Indianapolis

    EPA Science Inventory

    Complex mixtures of disinfection by-products (DBPs) are formed when the disinfectant oxidizes constituents (e.g., natural organic matter (NOM) and organic pollutants) found in the source water. Since 1974, over 600 DBPs have been identified in drinking water. Despite intense iden...

  5. Solar disinfection of water reduces diarrhoeal disease: an update

    PubMed Central

    Conroy, R.; Meegan, M. E.; Joyce, T.; McGuigan, K.; Barnes, J.

    1999-01-01

    349 Maasai children younger than 6 years old were randomised by alternate household to drink water either left in plastic bottles exposed to sunlight on the roof of the house or kept indoors (control). The trial was run in Maasai by Maasai community elders. Children drinking solar disinfected water had a significantly lower risk of severe diarrhoeal disease over 8705 two weekly follow up visits; two week period prevalence was 48.8% compared with 58.1% in controls, corresponding to an attributable fraction of 16.0%. While this reduction is modest, it was sustained over a year in free living children. It confirms solar disinfection as effective in vivo as a free, low technology, point of consumption method of improving water quality. The continuing use of solar disinfection by the community underlines the value of community participation in research.

 PMID:10490440

  6. MUTAGENICITY AND DISINFECTION BY-PRODUCTS IN SURFACE DRINKING WATER DISINFECTED WITH PERACETIC ACID

    EPA Science Inventory

    The aims of this research were to study the influence of peracetic acid (PAA) on the formation of mutagens in surface waters used for human consumption and to assess its potential application for the disinfection of drinking water. The results obtained using PAA were compared to ...

  7. Comparative study of disinfectants for use in low-cost gravity driven household water purifiers.

    PubMed

    Patil, Rajshree A; Kausley, Shankar B; Balkunde, Pradeep L; Malhotra, Chetan P

    2013-09-01

    Point-of-use (POU) gravity-driven household water purifiers have been proven to be a simple, low-cost and effective intervention for reducing the impact of waterborne diseases in developing countries. The goal of this study was to compare commonly used water disinfectants for their feasibility of adoption in low-cost POU water purifiers. The potency of each candidate disinfectant was evaluated by conducting a batch disinfection study for estimating the concentration of disinfectant needed to inactivate a given concentration of the bacterial strain Escherichia coli ATCC 11229. Based on the concentration of disinfectant required, the size, weight and cost of a model purifier employing that disinfectant were estimated. Model purifiers based on different disinfectants were compared and disinfectants which resulted in the most safe, compact and inexpensive purifiers were identified. Purifiers based on bromine, tincture iodine, calcium hypochlorite and sodium dichloroisocyanurate were found to be most efficient, cost effective and compact with replacement parts costing US$3.60-6.00 for every 3,000 L of water purified and are thus expected to present the most attractive value proposition to end users.

  8. Disinfection by-products in baby lettuce irrigated with electrolysed water.

    PubMed

    López-Gálvez, Francisco; Andújar, Silvia; Marín, Alicia; Tudela, Juan A; Allende, Ana; Gil, María I

    2018-06-01

    Irrigation water disinfection reduces the microbial load but it might lead to the formation and accumulation of disinfection by-products (DBPs) in the crop. If DBPs are present in the irrigation water, they can accumulate in the crop, particularly after the regrowth, and be affected by the postharvest handling such as washing and storage. To evaluate the potential accumulation of DBPs, baby lettuce was grown using irrigation water treated with electrolysed water (EW) in a commercial greenhouse over three consecutive harvests and regrowths. The impact of postharvest practices such as washing and storage on DBP content was also assessed. Use of EW caused the accumulation of chlorates in irrigation water (0.02-0.14 mg L -1 ), and in the fresh produce (0.05-0.10 mg kg -1 ). On the other hand, the disinfection treatment had minor impact regarding the presence of trihalomethanes (THMs) in water (0.3-8.7 μg L -1 max), and in baby lettuce (0.3-2.9 μg kg -1 max). Disinfection of irrigation water with EW caused the accumulation of chlorates in the crop reaching levels higher than the current maximum residual limit established in the EU legislation for leafy greens. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  9. ALTERNATIVE DISINFECTANTS FOR DRINKING WATER TREATMENT

    EPA Science Inventory

    During a one-year study at Jefferson Parish, Louisiana the chemical, microbiological, and mutagenic effects of using the major drinking water disinfectants (chlorine, chlorine dioxide, chloramine, ozone) were evaluated. ests were performed on samples collected from various treatm...

  10. Occurrence assessment for disinfectants and disinfection by-products (phase 6A) in public drinking water. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    The EPA Office of Ground Water and Drinking Water is developing national primary drinking water regulations for disinfectant and disinfection by-product contaminants. Thirteen contaminants are being considered to be regulated under Phase 6. These contaminants, referred to as Phase 6a, are the subject of the report. The information is important for setting the Maximum Contaminant Level Goal for a contaminant. The exposure information also is used to estimate the baseline health impact assessment of current levels and for evaluation of the health benefits of the regulatory alternatives.

  11. Disinfection By-Products and Drinking Water Treatment

    EPA Science Inventory

    The disinfection of drinking water has been rightly hailed as a public health triumph of the 20th century. Before its widespread use, millions of people died from waterborne diseases. Now, people in developed nations receive quality drinking water every day from their public wa...

  12. Long-term effects of disinfectants on the community composition of drinking water biofilms.

    PubMed

    Roeder, Rosemarie S; Lenz, Johannes; Tarne, Peter; Gebel, Jürgen; Exner, Martin; Szewzyk, Ulrich

    2010-06-01

    Numerous investigations have demonstrated efficiencies of different disinfection methods, but until now only little is known about long-term effects on community compositions of drinking water biofilms. Changes in the community structure, especially regrowth of hygienically relevant microorganisms could be critical for the drinking water quality. In this study the long-term effect of disinfection methods on biofilm communities in drinking water systems was analysed. Old drinking water biofilms grown in silicone tubes were exposed to different preparations of disinfectants (free chlorine, chlorine dioxide, hydrogen peroxide combined with fruit acid, silver and silver with peracetic acid, respectively) and subsequently further exposed in the original drinking water. The comparison of the treated and regrown biofilm populations with untreated ones by the DNA-fingerprinting method denaturing gradient gel electrophoresis (DGGE) revealed a considerable population shift caused by the disinfectants. The disinfection methods induced a selection pressure on the biofilm populations depending on the composition and concentrations. The similarities between the treated and untreated biofilms were generally low. Compared to preparations with peracetic acid the disinfection with hydrogen peroxide and silver resulted in higher similarities of the treated and untreated biofilms, but the microbial diversity increased. It can be concluded that the disinfectants have a major impact on the drinking water biofilm communities and that possibly the intervention selects persisters and microorganisms, which can live on the residuals of the dead biofilm cells. For the evaluation of the efficiency of disinfection methods in drinking water installations it is necessary not only to consider reduction of certain bacteria but also to pay attention to the biofilm community. Copyright 2010 Elsevier GmbH. All rights reserved.

  13. ALTERNATIVE DISINFECTION FOR DRINKING WATER TREATMENT

    EPA Science Inventory

    During a one-yr study at Jefferson Parish, La., the chemical, microbiological, and mutagenic effects os using the major drinkgin water disinfectants (chlorine, chlorine dioxide, chloramine, ozone) were evaluated. Tests were performed on samples collected from various treatment s...

  14. Efficacy of detergent and water versus bleach for disinfection of direct contact ophthalmic lenses.

    PubMed

    Abbey, Ashkan M; Gregori, Ninel Z; Surapaneni, Krishna; Miller, Darlene

    2014-06-01

    Although manufacturers recommend cleaning ophthalmic lenses with detergent and water and then with a specific disinfectant, disinfectants are rarely used in ophthalmic practices. The aim of this pilot study was to evaluate the efficacy of detergent and water versus that of bleach, a recommended disinfectant, to eliminate common ocular bacteria and viruses from ophthalmic lenses. Three bacterial strains (Staphylococcus epidermidis, Corynebacterium straitum, and methicillin-resistant Staphylococcus aureus and 2 viral strains (adenovirus and herpes simplex virus [HSV] type-1) were individually inoculated onto 20 gonioscopy and laser lenses. The lenses were washed with detergent and water and then disinfected with 10% bleach. All the lenses were cultured after inoculation, after washing with detergent and water, and after disinfecting with the bleach. Bacterial cultures in thioglycollate broth were observed for 3 weeks, and viral cultures were observed for 2 weeks. The presence of viruses was also detected by multiplex polymerase chain reaction (PCR). All 20 lenses inoculated with S. epidermidis, C. straitum, adenovirus, and HSV-1 showed growth after inoculation but no growth after washing with detergent/water and after disinfecting with the bleach. All lenses showed positive HSV and adenovirus PCR results after inoculation and negative PCR results after washing with detergent/water and after disinfecting with bleach. All methicillin-resistant S. aureus-contaminated lenses showed growth after inoculation and no growth after washing with detergent and water. However, 1 lens showed positive growth after disinfecting with bleach. Cleaning with detergent and water seemed to effectively eliminate bacteria and viruses from the surface of contaminated ophthalmic lenses. Further studies are warranted to design practical disinfection protocols that minimize lens damage.

  15. Regenerable Iodine Water-Disinfection System

    NASA Technical Reports Server (NTRS)

    Sauer, Richard L.; Colombo, Gerald V.; Jolly, Clifford D.

    1994-01-01

    Iodinated resin bed for disinfecting water regenerated to extend useful life. Water flows through regeneration bed of crystalline iodine during regeneration. At other times, flow diverted around regeneration bed. Although regeneration cycle manually controlled readily automated to start and stop according to signals from concentration sensors. Further benefit of regeneration is bed provides highly concentrated biocide source when needed. Concentrated biocide used to superiodinate system after contamination from routine maintenance or unexpected introduction of large concentration of microbes.

  16. THE UPTAKE OF WATER DISINFECTION BY-PRODUCTS INTO FOODS DURING HOME PROCESSING

    EPA Science Inventory

    A variety of organic compounds in tap water are produced as a result of disinfection process. Use of chlorine-containing chemicals for disinfection produces many disinfection by-products (DBPs) including trihalomethanes, haloacetonitriles and haloacetic acid. Ozonation with secon...

  17. Chlorine dioxide water disinfection: a prospective epidemiology study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Michael, G.E.; Miday, R.K.; Bercz, J.P.

    An epidemiologic study of 198 persons exposed for 3 months to drinking water disinfected with chlorine dioxide was conducted in a rural village. A control population of 118 nonexposed persons was also studied. Pre-exposure hematologic and serum chemical parameters were compared with test results after 115 days of exposure. Chlorite ion levels in the water averaged approximately 5 ppM during the study period. Statistical analysis (ANOVA) of the data failed to identify any significant exposure-related effects. This study suggests that future evaluations of chlorine dioxide disinfection should be directed toward populations with potentially increased sensitivity to hemolytic agents.

  18. Oxidation of the antibacterial agent norfloxacin during sodium hypochlorite disinfection of marine culture water.

    PubMed

    Zhang, Yuanyuan; Rong, Chuan; Song, Yanqun; Wang, Yinghui; Pei, Jiying; Tang, Xinying; Zhang, Ruijie; Yu, Kefu

    2017-09-01

    Chlorination disinfection and antibiotic addition are two universal processes of marine culture. The generation of disinfection byproducts (DBPs) is unavoidable. Antibiotic residue not only pollutes water but also acts as a precursor to the production of new DBPs. The fate of antibiotic norfloxacin (NOR) in chlorination disinfection was investigated. It was observed that NOR could be oxidized by disinfection agent sodium hypochlorite, but the oxidation rate varied considerably with the type of disinfected water. For fresh water, marine culture water and sea water, the reaction rate constant was 0.066 min -1 , 0.466 min -1 and 1.241 min -1 , respectively. The difference was primarily attributed to the promotion role of bromide ions in seawater and marine culture water. Moreover, the bromide ions could result in the generation of brominated DBPs (Br-DBPs). The kinetics, products, reaction centers and mechanisms were investigated. The active site of NOR was found to be the N4 atom on piperazinyl in fresh water. During marine culture water and sea water disinfection, the carboxyl on NOR was oxidized and two Br-DBPs were formed. This was attributed to the lowering of the reaction's required activation energy when performed in the presence of bromide ions. The Br-DBPs were also confirmed in real shrimp pond brackish water. Quantitative structure activity relationships and the total organic halogen analysis showed that the DBPs in marine culture water possessed stronger toxicological properties than the DBPs in fresh water. The toxicity increase was attributed to the production of Br-DBPs in the disinfection process of marine culture water. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Feasibility of the silver-UV process for drinking water disinfection.

    PubMed

    Butkus, Michael A; Talbot, Mark; Labare, Michael P

    2005-12-01

    A synergistic effect between cationic silver and UV radiation (silver-UV disinfection) has been observed that can appreciably enhance inactivation of viruses. The purpose of this work was to assess the feasibility of this technique for drinking water disinfection and evaluate the effects of selected impurities, found in fresh water, and common parameters on inactivation of the coliphage MS-2 with the silver-UV process. Turbidity (kaolin), calcium hardness, carbonate alkalinity, and pH did not significantly degrade inactivation. Inactivation was reduced in the presence of chloride, at concentrations greater than 30 mg/L, and in water samples with UV-254 absorbance values greater than ca. 0.1 cm(-1). Inactivation of MS-2 with silver-UV disinfection was also reduced at high phosphate concentrations (above ca. 5 mM). Silver-UV inactivation of MS-2 increased with increases in temperature between 10 and 20 degrees C. Silver-UV inactivation of MS-2 was increased by greater than 1-log over UV alone, in two untreated fresh water sources, which indicates that silver-UV may be a viable treatment technology. An assessment of operation and management costs suggests that an increase in inactivation of MS-2 with silver-UV disinfection could be economically beneficial.

  20. DISINFECTION BY-PRODUCTS IN DRINKING WATER TREATMENT SYSTEMS

    EPA Science Inventory

    Due to concerns over trihalomethanes (THMs) and other halogenated by-products that can be formed during chlorination of drinking water, alternative disinfectants are being explored. Several drinking water treatment plants in the United States have altered their treatment methods...

  1. CHARACTERIZING TOXICOLOGICALLY IMPORTANT DRINKING WATER DISINFECTION BY-PRODUCTS

    EPA Science Inventory

    Due to concerns over trihalomethanes (THMs) and other halogenated by-products that can be formed during chlorination of drinking water, alternative disinfectants are being explored. Several drinking water treatment plants in the United States have altered their treatment methods...

  2. Static electricity powered copper oxide nanowire microbicidal electroporation for water disinfection.

    PubMed

    Liu, Chong; Xie, Xing; Zhao, Wenting; Yao, Jie; Kong, Desheng; Boehm, Alexandria B; Cui, Yi

    2014-10-08

    Safe water scarcity occurs mostly in developing regions that also suffer from energy shortages and infrastructure deficiencies. Low-cost and energy-efficient water disinfection methods have the potential to make great impacts on people in these regions. At the present time, most water disinfection methods being promoted to households in developing countries are aqueous chemical-reaction-based or filtration-based. Incorporating nanomaterials into these existing disinfection methods could improve the performance; however, the high cost of material synthesis and recovery as well as fouling and slow treatment speed is still limiting their application. Here, we demonstrate a novel flow device that enables fast water disinfection using one-dimensional copper oxide nanowire (CuONW) assisted electroporation powered by static electricity. Electroporation relies on a strong electric field to break down microorganism membranes and only consumes a very small amount of energy. Static electricity as the power source can be generated by an individual person's motion in a facile and low-cost manner, which ensures its application anywhere in the world. The CuONWs used were synthesized through a scalable one-step air oxidation of low-cost copper mesh. With a single filtration, we achieved complete disinfection of bacteria and viruses in both raw tap and lake water with a high flow rate of 3000 L/(h·m(2)), equivalent to only 1 s of contact time. Copper leaching from the nanowire mesh was minimal.

  3. Review of electrotechnologies used in the disinfection of water and wastewater. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    VandeVenter, L.W.

    This report provides an overview of the disinfection practices used in water and wastewater treatment. Chlorine historically has been the disinfectant of choice for both water and wastewater, but with increased research and more stringent regulations, other disinfectants, namely ozone and ultraviolet irradiation, are being considered. The report summarizes the present and future applications of these technologies and defines possible opportunities for Demand- Side Management (DSM).

  4. Drinking water and biofilm disinfection by Fenton-like reaction.

    PubMed

    Gosselin, F; Madeira, L M; Juhna, T; Block, J C

    2013-10-01

    A Fenton-like disinfection process was conducted with Fenton's reagent (H2O2) at pH 3 or 5 on autochthonous drinking water biofilms grown on corroded or non-corroded pipe material. The biofilm disinfection by Fenton-like oxidation was limited by the low content of iron and copper in the biomass grown on non-corroded plumbing. It was slightly improved by spiking the distribution system with some additional iron source (soluble iron II or ferrihydrite particles appeared as interesting candidates). However successful in situ disinfection of biofilms was only achieved in fully corroded cast iron pipes using H2O2 and adjusting the pH to 5. These new results provide additional support for the use of Fenton's processes for cleaning drinking water distribution systems contaminated with biological agents or organics. Copyright © 2013 Elsevier Ltd. All rights reserved.

  5. EVALUATION OF ON-SITE CHLORINE GENERATORS FOR THE DISINFECTION OF DRINKING WATER

    EPA Science Inventory

    Public Water Systems (PWSs) routinely use various forms of chlorine as the disinfectant of choice for the treatment of drinking water. Chlorine is a popular choice because it is a very effective disinfectant, it is inexpensive, and it is widely available in various forms to suit...

  6. 40 CFR 141.72 - Disinfection.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... PRIMARY DRINKING WATER REGULATIONS Filtration and Disinfection § 141.72 Disinfection. A public water... the direct influence of surface water and provides filtration treatment must provide disinfection...) Disinfection requirements for public water systems which provide filtration. Each public water system that...

  7. Peracetic acid in the disinfection of a hospital water system contaminated with Legionella species.

    PubMed

    Ditommaso, Savina; Biasin, Cinzia; Giacomuzzi, Monica; Zotti, Carla Maria; Cavanna, Alberto; Ruggenini Moiraghi, Angela

    2005-05-01

    To assess the efficacy of an alternative disinfection method for hospital water distribution systems contaminated with Legionella. Disinfection with peracetic acid was performed in a small hospital contaminated with L. pneumophila serotype 1. The disinfectant was used at concentrations of 50 ppm (first three surveillance phases) and 1,000 ppm (fourth surveillance phase) for 30 minutes. Environmental monitoring revealed that disinfection was maintained 1 week after treatment; however, levels of recontamination surpassing baseline values were detected after approximately 1 month. Comparison of water temperatures measured at the distal outlets showed a statistically significant association between temperature and bacterial load. The circulating water temperature was found to be lower in the two wards farthest away from the hot water production plant than in other wards. It was thought that the lower water temperature in the two wards promoted the bacterial growth even after disinfection. Peracetic acid may be useful in emergency situations, but does not provide definitive protection even if used monthly.

  8. Calibration and characterization of UV sensors for water disinfection

    NASA Astrophysics Data System (ADS)

    Larason, T.; Ohno, Y.

    2006-04-01

    The National Institute of Standards and Technology (NIST), USA is participating in a project with the American Water Works Association Research Foundation (AwwaRF) to develop new guidelines for ultraviolet (UV) sensor characteristics to monitor the performance of UV water disinfection plants. The current UV water disinfection standards, ÖNORM M5873-1 and M5873-2 (Austria) and DVGW W294 3 (Germany), on the requirements for UV sensors for low-pressure mercury (LPM) and medium-pressure mercury (MPM) lamp systems have been studied. Additionally, the characteristics of various types of UV sensors from several different commercial vendors have been measured and analysed. This information will aid in the development of new guidelines to address issues such as sensor requirements, calibration methods, uncertainty and traceability. Practical problems were found in the calibration methods and evaluation of spectral responsivity requirements for sensors designed for MPM lamp systems. To solve the problems, NIST is proposing an alternative sensor calibration method for MPM lamp systems. A future calibration service is described for UV sensors intended for low- and medium-pressure mercury lamp systems used in water disinfection applications.

  9. The Recreational Water Cycle: From Source Water to Tap Water to Spa and Swimming Pool Water: Effects of Disinfectants and Precursors and Implications for Exposure and Toxicity

    EPA Science Inventory

    The current study investigates the effect of different disinfection treatments on the disinfection by-products (DBPs) formed in finished drinking water vs. tap water vs. swimming pool water vs. spa waters. To this end, complete water pathway samples (untreated source waters ->fi...

  10. Disinfection of water in recirculating aquaculture systems with peracetic acid

    USDA-ARS?s Scientific Manuscript database

    Peracetic acid (PAA) has become a favoured alternative to chlorination in the disinfection of municipal waste water in recent years. It is also commonly used in the food industry as a disinfectant. Based on PAA concentration, the disulfide linkage in enzymes and proteins of microorganisms can be bro...

  11. Disinfection of bore well water with chlorine dioxide/sodium hypochlorite and hydrodynamic cavitation.

    PubMed

    Wang, Yifei; Jia, Aiyin; Wu, Yue; Wu, Chunde; Chen, Lijun

    2015-01-01

    The effect of hydrodynamic cavitation (HC) on potable water disinfection of chemicals was investigated. The bore well water was introduced into HC set-up to examine the effect of HC alone and combination of HC and chemicals such as chlorine dioxide and sodium hypochlorite. The effect of inlet pressure and geometrical parameters on disinfection was studied using HC alone and the results showed that increasing inlet pressure and using more and bigger holes of orifice plates can result in a higher disinfection rates. When HC was combined with chemicals, HC can reduce the doses of the chemicals and shorten the time of disinfection. It was also found that the decrease in bacteria concentration followed a first-order kinetic model. As for the experiment of combination of HC and sodium hypochlorite for disinfection, HC not only improves the disinfection rate but also degrades natural organic matter and chloroform. Compared with only sodium hypochlorite disinfection, combined processes get higher disinfection rate and lower production of chloroform, particularly the pretreatment with HC enhances the disinfection rate by 32% and there is a simultaneous reduction in production of chloroform by 39%.

  12. Regenerable Iodine Water-Disinfection System

    NASA Technical Reports Server (NTRS)

    Sauer, Richard L.; Colombo, Gerald V.; Jolly, Clifford D.

    1994-01-01

    Iodinated resin bed for disinfecting water regenerated to extend its useful life. Water flows through regeneration bed of crystalline iodine during regeneration. At other times, flow diverted around regeneration bed. Although regeneration cycle was manually controlled in demonstration, readily automated to start and stop according to signals and stop according to signals from concentration sensors. Further benefit of regeneration is that regeneration bed provides highly concentrated biocide source (200 mg/L) when needed. Concentrated biocide used to superiodinate system after contamination from routine maintenance or unexpected introduction of large concentration of microbes.

  13. IDENTIFICATION OF CHLORINE DIOXIDE AND CHLORAMINE DRINKING WATER DISINFECTION BY-PRODUCTS

    EPA Science Inventory

    Due to concern over the potential adverse health effects of trihalomethanes (THMs) and other chlorinated by-products in chlorinated drinking water, alternative disinfection methods are being explored. Chlorine dioxide and chloramine are two popular alternative disinfectants, with...

  14. Solar disinfection of drinking water protects against cholera in children under 6 years of age

    PubMed Central

    Conroy, R; Meegan, M; Joyce, T; McGuigan, K; Barnes, J

    2001-01-01

    BACKGROUND AND AIMS—We have previously reported a reduction in risk of diarrhoeal disease in children who used solar disinfected drinking water. A cholera epidemic, occurring in an area of Kenya in which a controlled trial of solar disinfection and diarrhoeal disease in children aged under 6 had recently finished, offered an opportunity to examine the protection offered by solar disinfection against cholera.
METHODS—In the original trial, all children aged under 6 in a Maasai community were randomised by household: in the solar disinfection arm, children drank water disinfected by leaving it on the roof in a clear plastic bottle, while controls drank water kept indoors. We revisited all households which had participated in the original trial.
RESULTS—There were 131 households in the trial area, of which 67 had been randomised to solar disinfection (a further 19 households had migrated as a result of severe drought). There was no significant difference in the risk of cholera in adults or in older children in households randomised to solar disinfection; however, there were only three cases of cholera in the 155 children aged under 6 years drinking solar disinfected water compared with 20 of 144controls.
CONCLUSIONS—Results confirm the usefulness of solar disinfection in reducing risk of water borne disease in children. Point of consumption solar disinfection can be done with minimal resources, which are readily available, and may be an important first line response to cholera outbreaks. Its potential in chorine resistant cholera merits further investigation.

 PMID:11567937

  15. Differential toxicity of drinking water disinfected with combinations of ultraviolet radiation and chlorine.

    PubMed

    Plewa, Michael J; Wagner, Elizabeth D; Metz, Deborah H; Kashinkunti, Ramesh; Jamriska, Katherine J; Meyer, Maria

    2012-07-17

    Alternative technologies to disinfect drinking water such as ultraviolet (UV) disinfection are becoming more widespread. The benefits of UV disinfection include reduced risk of microbial pathogens such as Cryptosporidium and reduced production of regulated drinking water disinfection byproducts (DBPs). The objective of this research was to determine if mammalian cell cytotoxicity and genotoxicity varied in response to different chlorination protocols with and without polychromatic medium pressure UV (MPUV) and monochromatic low pressure UV (LPUV) disinfection technologies. The specific aims were to analyze the mammalian cell cytotoxicity and genotoxicity of concentrated organic fractions from source water before and after chlorination and to determine the cytotoxicity and genotoxicity of the concentrated organic fractions from water samples treated with UV alone or UV before or after chlorination. Exposure of granular activated carbon-filtered Ohio River water to UV alone resulted in the lowest levels of mammalian cell cytotoxicity and genotoxicity. With combinations of UV and chlorine, the lowest levels of cytotoxicity and genotoxicity were observed with MPUV radiation. The best combined UV plus chlorine methodology that generated the lowest cytotoxicity and genotoxicity employed chlorination first followed by MPUV radiation. These data may prove important in the development of multibarrier methods of pathogen inactivation of drinking water, while limiting unintended toxic consequences.

  16. Genotoxicity of drinking water treated with different disinfectants and effects of disinfection conditions detected by umu-test.

    PubMed

    Nie, Xuebiao; Liu, Wenjun; Zhang, Liping; Liu, Qing

    2017-06-01

    The genotoxicity of drinking water treated with 6 disinfection methods and the effects of disinfection conditions were investigated using the umu-test. The pretreatment procedure of samples for the umu-test was optimized for drinking water analysis. The results of the umu-test were in good correlation with those of the Ames-test. The genotoxicity and production of haloacetic acids (HAAs) were the highest for chlorinated samples. UV+chloramination is the safest disinfection method from the aspects of genotoxicity, HAA production and inactivation effects. For chloramination, the effects of the mass ratio of Cl 2 to N of chloramine on genotoxicity were also studied. The changes of genotoxicity were different from those of HAA production, which implied that HAA production cannot represent the genotoxic potential of water. The genotoxicity per chlorine decay of chlorination and chloramination had similar trends, indicating that the reaction of organic matters and chlorine made a great contribution to the genotoxicity. The results of this study are of engineering significance for optimizing the operation of waterworks. Copyright © 2016. Published by Elsevier B.V.

  17. The halosol process for water disinfection and dehalogenation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Acra, A.; Jurdi, M.; Mu'allem, H.

    Substitution of chlorine and its derivatives as agents to disinfect water and wastewater effluents because of concern for the formation of the mutagenic and carcinogenic trihalomethanes (THM) may be a protracted endeavor. Excess chlorine residuals need to be controlled by dechlorinated agents, e.g., SO{sub 2}, to avoid esthetic objections voiced by consumers and the risk to aquatic environments. We focused on the phenomenon of photodecomposition and aqueons halogen solutions by sunlight. The halosol process, a batch system for solar dehalogenation, was developed into a flow-through system for the halosol disinfection of water. A prototype facility incorporated a solar reactor, throughmore » which chlorinated water flowed, made of borosilicate glass tube with a serpentine shape supported by a frame. Disinfection is induced by two cooperative biocidal agents (a halogen and sunlight) with sequential solar dehalogenation. An overall mean photodechlorination rate, K, of 0.238 m{sup 2}/W-h was obtained. The calculated solar UV-A fluence required to reduce the initial chlorine residuals by 90% and 99% was 9.65 and 19.30 W-h/m{sup 2}. The most effective photodechlorination components of sunlight were in the UV-A region of the spectrum: effectiveness decreased exponentially with wavelength.« less

  18. Methemoglobinemia in critically ill patients during extended hemodialysis and simultaneous disinfection of the hospital water supply

    PubMed Central

    2009-01-01

    Introduction To evaluate the cause of methemoglobinemia in patients undergoing extended daily hemodialysis/hemodiafiltration we analyzed the relationship between methemoglobinemia and the water disinfection schedule of the hospital. Methods We reviewed all arterial blood gas analyses, obtained over a one-year period, in patients undergoing extended hemodialysis/hemodiafiltration, and compared the methemoglobin concentrations obtained on the days when the water supply was disinfected, using a hydrogen peroxide/silver ion preparation, with data measured on disinfection-free days. Results The evaluation of 706 measurements revealed a maximum methemoglobin fraction of 1.0 (0.8; 1.2) % (median and 25th; 75th percentiles) during hemodialysis/hemodiafiltration on the disinfection-free days. The methemoglobin fraction increased to 5.9 (1.3; 8.4) % with a maximal value of 12.2% on the days of water disinfection (P < 0.001 compared to disinfection-free days). Spot checks on hydrogen peroxide concentrations in the water supply, the permeate, and the dialysate, using a semi-quantitative test, demonstrated levels between 10 and 25 mg/l during water disinfection. Conclusions Our results demonstrate that even a regular hospital water disinfection technique can be associated with significant methemoglobinemia during extended hemodialysis. Clinicians should be aware of this potential hazard. PMID:19821985

  19. High-performance, low-cost solar collectors for disinfection of contaminated water.

    PubMed

    Vidal, A; Diaz, A I

    2000-01-01

    Although the germicidal action of sunlight has long been recognized, its potential for practical applications has to be researched more thoroughly. This paper summarizes the progress made toward a commercially practical collector for solar disinfection applications. Nontracking compound parabolic collectors (CPCs), developed originally for capturing solar photons for thermal energy applications, were examined as potential solar photoreactors. A field demonstration of solar disinfection treatment using commercially manufactured solar reactors was conducted. Field tests showed successful destruction of Escherichia coli and Enterococcus faecalis and have provided data for full-scale design of water treatment systems. From above observations, a throughput value of 50 L/m2 h for the low-cost CPC reactor tested was estimated. For a 190 m3/d (0.05 MGD) facility, the estimated total costs for disinfection using UV-A is U.S. $0.19/m3 ($0.70/1000 gal). The use of near-UV sunlight to disinfect water supplies seems promising in rural communities of developing countries where treated water is unavailable.

  20. Toxicity evaluation of surface water treated with different disinfectants in HepG2 cells.

    PubMed

    Marabini, Laura; Frigerio, Silvia; Chiesara, Enzo; Radice, Sonia

    2006-01-01

    It is well known that water disinfection through chlorination causes the formation of a mixture of disinfection by-products (DBPs), many of which are genotoxic and carcinogenic. To demonstrate the formation of such compounds, a pilot water plant supplied with water from Lake Trasimeno was set up at the waterworks of Castiglione del Lago (PG, Italy). The disinfectants, continuously added to pre-filtered lake water flowing into three different basins, were sodium hypochlorite, chlorine dioxide and peracetic acid, an alternative disinfectant used until now for disinfecting waste waters, but not yet studied for a possible use in drinking water treatment. The aim of this study was to evaluate the formation during the disinfection processes of some toxic compounds that could explain the genotoxic effects of drinking waters. Differently treated waters were concentrated by solid-phase adsorption on silica C(18) columns and toxicity was assessed in a line of human hepatoma cells (HepG2), a metabolically competent cellular line very useful for human risk evaluation. The seasonal variability of the physical-chemical water characteristics (AOX, UV 254 nm, potential formation of THM, pH and temperature) made indispensable experimentation with water samples taken during the various seasons. Autumn waters cause greater toxicity compared to those of other seasons, in particular dilution of the concentrate at 0.5l equivalent of disinfected waters with chlorine dioxide and peracetic acid causes a 55% reduction in cellular vitality while the cellular vitality is over 80% with the all other water concentrates. Moreover it is very interesting underline that non-cytotoxic quantities of the autumnal water concentrates cause, after 2h treatment, a decrease in GSH and a statistically significant increase in oxygen radicals, while after prolonged treatment (24h) cause a GSH increase, without variations in the oxygen radical content. This phenomenon could be interpreted as the cellular

  1. An overview of water disinfection in developing countries and the potential for solar thermal water pasteurization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Burch, J.; Thomas, K.E.

    This study originated within the Solar Buildings Program at the U.S. Department of Energy. Its goal is to assess the potential for solar thermal water disinfection in developing countries. In order to assess solar thermal potential, the alternatives must be clearly understood and compared. The objectives of the study are to: (a) characterize the developing world disinfection needs and market; (b) identify competing technologies, both traditional and emerging; (c) analyze and characterize solar thermal pasteurization; (d) compare technologies on cost-effectiveness and appropriateness; and (e) identify research opportunities. Natural consequences of the study beyond these objectives include a broad knowledge ofmore » water disinfection problems and technologies, introduction of solar thermal pasteurization technologies to a broad audience, and general identification of disinfection opportunities for renewable technologies.« less

  2. Aggregation of Adenovirus 2 in Source Water and Impacts on Disinfection by Chlorine

    PubMed Central

    Cromeans, Theresa L.; Metcalfe, Maureen G.; Humphrey, Charles D.; Hill, Vincent R.

    2016-01-01

    It is generally accepted that viral particles in source water are likely to be found as aggregates attached to other particles. For this reason, it is important to investigate the disinfection efficacy of chlorine on aggregated viruses. A method to produce adenovirus particle aggregation was developed for this study. Negative stain electron microscopy was used to measure aggregation before and after addition of virus particles to surface water at different pH and specific conductance levels. The impact of aggregation on the efficacy of chlorine disinfection was also examined. Disinfection experiments with human adenovirus 2 (HAdV2) in source water were conducted using 0.2 mg/L free chlorine at 5 °C. Aggregation of HAdV2 in source water (≥3 aggregated particles) remained higher at higher specific conductance and pH levels. However, aggregation was highly variable, with the percentage of particles present in aggregates ranging from 43 to 71 %. Upon addition into source water, the aggregation percentage dropped dramatically. On average, chlorination CT values (chlorine concentration in mg/L × time in min) for 3-log10 inactivation of aggregated HAdV2 were up to three times higher than those for dispersed HAdV2, indicating that aggregation reduced the disinfection rate. This information can be used by water utilities and regulators to guide decision making regarding disinfection of viruses in water. PMID:26910058

  3. Effect of Disinfectants on Preventing the Cross-Contamination of Pathogens in Fresh Produce Washing Water

    PubMed Central

    Banach, Jennifer L.; Sampers, Imca; Van Haute, Sam; van der Fels-Klerx, H.J. (Ine)

    2015-01-01

    The potential cross-contamination of pathogens between clean and contaminated produce in the washing tank is highly dependent on the water quality. Process wash water disinfectants are applied to maintain the water quality during processing. The review examines the efficacy of process wash water disinfectants during produce processing with the aim to prevent cross-contamination of pathogens. Process wash water disinfection requires short contact times so microorganisms are rapidly inactivated. Free chlorine, chlorine dioxide, ozone, and peracetic acid were considered suitable disinfectants. A disinfectant’s reactivity with the organic matter will determine the disinfectant residual, which is of paramount importance for microbial inactivation and should be monitored in situ. Furthermore, the chemical and worker safety, and the legislative framework will determine the suitability of a disinfection technique. Current research often focuses on produce decontamination and to a lesser extent on preventing cross-contamination. Further research on a sanitizer’s efficacy in the washing water is recommended at the laboratory scale, in particular with experimental designs reflecting industrial conditions. Validation on the industrial scale is warranted to better understand the overall effects of a sanitizer. PMID:26213953

  4. Vulnerability of water distribution systems to pathogen intrusion: how effective is a disinfectant residual?

    PubMed

    Propato, Marco; Uber, James G

    2004-07-01

    Can the spread of infectious disease through water distribution systems be halted by a disinfectant residual? This question is overdue for an answer. Regulatory agencies and water utilities have long been concerned about accidental intrusions of pathogens into distribution system pipelines (i.e., cross-connections) and are increasingly concerned about deliberate pathogen contamination. Here, a simulation framework is developed and used to assess the vulnerability of a water system to microbiological contamination. The risk of delivering contaminated water to consumers is quantified by a network water quality model that includes disinfectant decay and disinfection kinetics. The framework is applied to two example networks under a worst-case deliberate intrusion scenario. Results show that the risk of consumer exposure is affected by the residual maintenance strategy employed. The common regulation that demands a "detectable" disinfectant residual may not provide effective consumer protection against microbial contamination. A chloramine residual, instead of free chlorine, may significantly weaken this final barrier against pathogen intrusions. Moreover, the addition of a booster station at storage tanks may improve consumer protection without requiring excessive disinfectant.

  5. Development of an Ultrasonic Resonator for Ballast Water Disinfection

    NASA Astrophysics Data System (ADS)

    Osman, Hafiiz; Lim, Fannon; Lucas, Margaret; Balasubramaniam, Prakash

    Ultrasonic disinfection involves the application of low-frequency acoustic energy in a water body to induce cavitation. The implosion of cavitation bubbles generates high speed microjets >1 km/s, intense shock wave >1 GPa, localized hot spots >1000 K, and free-radicals, resulting in cell rupture and death of micro-organisms and pathogens. Treatment of marine ballast water using power ultrasonics is an energy-intensive process. Compared with other physical treatment methods such as ultraviolet disinfection, ultrasonic disinfection require 2 to 3 orders of magnitude more energy to achieve similar rate of micro-organism mortality. Current technology limits the amount of acoustic energy that can be transferred per unit volume of fluid and presents challenges when it comes to high-flow applications. Significant advancements in ultrasonic processing technology are needed before ultrasound can be recognized as a viable alternative disinfection method. The ultrasonic resonator has been identified as one of the areas of improvement that can potentially contribute to the overall performance of an ultrasonic disinfection system. The present study focuses on the design of multiple-orifice resonators (MOR) for generating a well-distributed cavitation field. Results show that the MOR resonator offers significantly larger vibrational surface area to mass ratio. In addition, acoustic pressure measurements indicate that the MOR resonators are able to distribute the acoustic energy across a larger surface area, while generating 2-4 times higher pressures than existing ultrasonic probes.

  6. OCCURRENCE AND TOXICITY OF IODINATED DISINFECTION BY-PRODUCTS IN DRINKING WATER

    EPA Science Inventory

    As part of a recent Nationwide Disinfection By-Product (DBP) Occurrence Study, iodo-acids were identified for the first time as DBPs in drinking water disinfected with chloramines. The iodo-acids identified included iodoacetic acid, bromoiodoacetic acid, (E)-3-bromo-3-iodo-prope...

  7. Synergistic effect of solar radiation and solar heating to disinfect drinking water sources.

    PubMed

    Rijal, G K; Fujioka, R S

    2001-01-01

    Waterborne diseases are still common in developing countries as drinking water sources are contaminated and feasible means to reliably treat and disinfect these waters are not available. Many of these developing countries are in the tropical regions of the world where sunlight is plentiful. The objective of this study was to evaluate the effectiveness of combining solar radiation and solar heating to disinfect contaminated water using a modified Family Sol*Saver System (FSP). The non-UV transmittable cover sheet of the former FSP system was replaced with an UV transmittable plastic cover sheet to enable more wavelengths of sunlight to treat the water. Disinfection efficiency of both systems was evaluated based on reduction of the natural populations of faecal coliform, E. coli, enterococci, C. perfringens, total heterotrophic bacteria, hydrogen sulphide producing bacteria and FRNA virus. The results showed that under sunny and partly sunny conditions, water was heated to critical temperature (60 degrees C) in both the FSP systems inactivating more than 3 log (99.9%) of the concentrations of faecal coliform and E. coli to undetectable levels of < 1 CFU/100 mL within 2-5 h exposure to sunlight. However, under cloudy conditions, the two FSP systems did not reduce the concentrations of faecal indicator bacteria to levels of < 1 CFU/100 mL. Nonetheless, sufficient evidence was obtained to show that UV radiation of sunlight plus heat worked synergistically to enhance the inactivation of faecal indicator bacteria. The relative log removal of indicator microorganism in the FSP treated water was total heterotrophic bacteria < C. perfringens < F RNA virus < enterococci < E. coli < faecal coliform. In summary, time of exposure to heat and radiation effects of sunlight were important in disinfecting water by solar units. The data indicated that direct radiation of sunlight worked synergistically with solar heating of the water to disinfect the water. Thus, effective

  8. Corrosion control and disinfection studies in spacecraft water systems. [considering Saturn 5 orbital workshop

    NASA Technical Reports Server (NTRS)

    Shea, T. G.

    1974-01-01

    Disinfection and corrosion control in the water systems of the Saturn 5 Orbital Workshop Program are considered. Within this framework, the problem areas of concern are classified into four general areas: disinfection; corrosion; membrane-associated problems of disinfectant uptake and diffusion; and taste and odor problems arising from membrane-disinfectant interaction.

  9. Ultraviolet light-emitting diodes in water disinfection.

    PubMed

    Vilhunen, Sari; Särkkä, Heikki; Sillanpää, Mika

    2009-06-01

    The novel system of ultraviolet light-emitting diodes (UV LEDs) was studied in water disinfection. Conventional UV lamps, like mercury vapor lamp, consume much energy and are considered to be problem waste after use. UV LEDs are energy efficient and free of toxicants. This study showed the suitability of LEDs in disinfection and provided information of the effect of two emitted wavelengths and different test mediums to Escherichia coli destruction. Common laboratory strain of E. coli (K12) was used and the effects of two emitted wavelengths (269 and 276 nm) were investigated with two photolytic batch reactors both including ten LEDs. The effects of test medium were examined with ultrapure water, nutrient and water, and nutrient and water with humic acids. Efficiency of reactors was almost the same even though the one emitting higher wavelength had doubled optical power compared to the other. Therefore, the effect of wavelength was evident and the radiation emitted at 269 nm was more powerful. Also, the impact of background was studied and noticed to have only slight deteriorating effect. In the 5-min experiment, the bacterial reduction of three to four log colony-forming units (CFU) per cubic centimeter was achieved, in all cases. When turbidity of the test medium was greater, part of the UV radiation was spent on the absorption and reactions with extra substances on liquid. Humic acids can also coat the bacteria reducing the sensitivity of the cells to UV light. The lower wavelength was distinctly more efficient when the optical power is considered, even though the difference of wavelengths was small. The reason presumably is the greater absorption of DNA causing more efficient bacterial breakage. UV LEDs were efficient in E. coli destruction, even if LEDs were considered to have rather low optical power. The effect of wavelengths was noticeable but the test medium did not have much impact. This study found UV LEDs to be an optimal method for bacterial

  10. COMPONENT-BASED AND WHOLE-MIXTURE TECHNIQUES FOR ADDRESSING THE TOXICITY OF DRINKING-WATER DISINFECTION BY-PRODUCT MIXTURES

    EPA Science Inventory

    Chemical disinfection of water is of direct public health benefit as it results in decreased waterborne illness. The chemicals used to disinfect water react with naturally occurring organic matter, bromide and iodide in the source water, resulting in the formation of disinfection...

  11. Carbon nanoparticles for solar disinfection of water.

    PubMed

    Maddigpu, Pratap Reddy; Sawant, Bhairavi; Wanjari, Snehal; Goel, M D; Vione, Davide; Dhodapkar, Rita S; Rayalu, S

    2018-02-05

    The present manuscript deals with the application of carbon nano particles (CNP) and chitosan (CHIT) in the form of CHIT-CNP composite for the disinfection of water. The CHIT-CNP composite was prepared by the solution casting method and characterized by TEM, XRD and elemental analysis. In the present investigation we study the disinfection efficiency towards E. coli bacteria of both CNP and CHIT-CNP, under sunlight (SODIS) in identical experimental conditions. Both CNP and CHIT-CNP enhanced disinfection as compared to SODIS alone, and comparable performance was achieved when the same dose of CNP in the two materials was applied. However, the CHIT-CNP composite is in the form of a fabric and it is easier to use and handle as compared to the CNP powder, especially in rural and resource-constrained areas. Moreover the SODIS-CHIT-CNP setup, when used in a compound parabolic collector (CPC) reactor showed high bactericidal efficiency compared to SODIS alone, which is promising for practical applications. The disinfection potential of the CNP powder was compared with that of the well-known material TiO 2 Degussa P25 (DP 25 ): DP 25 gave 6-log kill of bacteria in 180min, whereas CNP produced 6-log kill in 150min. Copyright © 2017. Published by Elsevier B.V.

  12. Risk assessment of waste-water disinfection. Report for October 1979-January 1984

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hubly, D.; Chappell, W.; Lanning, J.

    A risk-assessment data base is presented for several waste-water disinfection alternatives, including chlorination, ozonation, chlorination/dechlorination, and ultraviolet radiation. The data base covers hazards and consequences related to onsite use and transportation of the disinfectants and ultimate disposal of disinfected effluents. A major segment of the data base deals with the effects of chlorination products in aquatic ecosystems. Energy consumption and cost analyses are also presented for chlorination and ozonation. Example risk calculations are presented for two hypothetical waste-water treatment plants. The usefulness of the data base for risk assessment is also discussed.

  13. [Complex technology for water and wastewater disinfection and its industrial realization in prototype unit].

    PubMed

    Arakcheev, E N; Brunman, V E; Brunman, M V; Konyashin, A V; Dyachenko, V A; Petkova, A P

    Usage of complex automated electrolysis unit for drinking water disinfection and wastewater oxidation and coagulation is scoped, its ecological and energy efficiency is shown. Properties of technological process of anolyte production using membrane electrolysis of brine for water disinfection in municipal pipelines and potassium ferrate production using electrochemical dissolution of iron anode in NaOH solution for usage in purification plants are listed. Construction of modules of industrial prototype for anolyte and ferrate production and applied aspects of automation of complex electrolysis unit are proved. Results of approbation of electrolytic potassium ferrate for drinking water disinfection and wastewater, rain water and environmental water oxidation and coagulation are shown.

  14. Aggregation of Adenovirus 2 in Source Water and Impacts on Disinfection by Chlorine.

    PubMed

    Kahler, Amy M; Cromeans, Theresa L; Metcalfe, Maureen G; Humphrey, Charles D; Hill, Vincent R

    2016-06-01

    It is generally accepted that viral particles in source water are likely to be found as aggregates attached to other particles. For this reason, it is important to investigate the disinfection efficacy of chlorine on aggregated viruses. A method to produce adenovirus particle aggregation was developed for this study. Negative stain electron microscopy was used to measure aggregation before and after addition of virus particles to surface water at different pH and specific conductance levels. The impact of aggregation on the efficacy of chlorine disinfection was also examined. Disinfection experiments with human adenovirus 2 (HAdV2) in source water were conducted using 0.2 mg/L free chlorine at 5 °C. Aggregation of HAdV2 in source water (≥3 aggregated particles) remained higher at higher specific conductance and pH levels. However, aggregation was highly variable, with the percentage of particles present in aggregates ranging from 43 to 71 %. Upon addition into source water, the aggregation percentage dropped dramatically. On average, chlorination CT values (chlorine concentration in mg/L × time in min) for 3-log10 inactivation of aggregated HAdV2 were up to three times higher than those for dispersed HAdV2, indicating that aggregation reduced the disinfection rate. This information can be used by water utilities and regulators to guide decision making regarding disinfection of viruses in water.

  15. Highly Bactericidal Macroporous Antimicrobial Polymeric Gel for Point-of-Use Water Disinfection.

    PubMed

    Kumar, Amit; Boyer, Cyrille; Nebhani, Leena; Wong, Edgar H H

    2018-05-21

    Access to clean and safe water supply remains inadequate in many developing countries. One of the key challenges is to remove pathogenic bacteria from the water supply via effective water disinfection technologies to prevent the spread of diseases and to ensure the safety of consumers. Herein, a highly effective point-of-use (on-demand) water disinfection technology, in the form of a polymeric scaffold called macroporous antimicrobial polymeric gel (MAPG), is demonstrated. MAPG is easy to fabricate, completely organic and possess inherent antimicrobial property which makes it non-reliant on inorganic compounds such as silver where the long-term toxicity remains unknown. MAPG is highly bactericidal and can disinfect bacteria-contaminated water (ca. 10 8  CFU mL -1 ) at a capacity of about >50 times the mass of the organic material used, inactivating >99% of both Gram-negative and Gram-positive bacteria including Escherichia coli, Vibrio cholerae and Staphylococcus aureus within 20 minutes of treatment. When fabricated in a syringe, MAPG eliminates E. coli from contaminated water source by >8.0 log 10 reduction in bacteria counts (i.e., no viable bacteria were detected after treatment), and the syringe can be reused multiple times without losing potency. The MAPG technology is not only restricted to water disinfection but may also be applicable in other bacteria inactivation applications.

  16. Evaluation of Electrochemically Generated Potable Water Disinfectants for Use on the International Space Station

    NASA Technical Reports Server (NTRS)

    Vega, Leticia; Aber, Gregory; Adam, Niklas; Clements, Anna; Modica, Catherine; Younker, Diane

    2011-01-01

    Microbial contamination and subsequent growth in spacecraft water systems are constant concerns for missions involving human crews. The current potable water disinfectant is iodine; however, with the end of the Space Shuttle program, there is a need to develop redundant biocide systems which are less dependent on hardware that would need to be launched on a regular basis. Three systems for electrochemical production of potable water disinfectants are being assessed for use on the International Space Station (ISS). Since there is a wide variability in the literature with regards to efficacy in both concentration and exposure time of these disinfectants, there is a need to establish baseline efficacy values. This paper describes a series of tests performed in order to establish optimal concentrations and exposure times for four disinfectants against single and mixed species planktonic and biofilm bacteria and to determine whether these electrochemical disinfection devices are able to produce a sufficient amount of chemical in both concentration and volume to act as a biocide for potable water on ISS.

  17. Assessment and management of the performance risk of a pilot reclaimed water disinfection process.

    PubMed

    Zhou, Guangyu; Zhao, Xinhua; Zhang, Lei; Wu, Qing

    2013-10-01

    Chlorination disinfection has been widely used in reclaimed water treatment plants to ensure water quality. In order to assess the downstream quality risk of a running reclaimed water disinfection process, a set of dynamic equations was developed to simulate reactions in the disinfection process concerning variables of bacteria, chemical oxygen demand (COD), ammonia and monochloramine. The model was calibrated by the observations obtained from a pilot disinfection process which was designed to simulate the actual process in a reclaimed water treatment plant. A Monte Carlo algorithm was applied to calculate the predictive effluent quality distributions that were used in the established hierarchical assessment system for the downstream quality risk, and the key factors affecting the downstream quality risk were defined using the Regional Sensitivity Analysis method. The results showed that the seasonal upstream quality variation caused considerable downstream quality risk; the effluent ammonia was significantly influenced by its upstream concentration; the upstream COD was a key factor determining the process effluent risk of bacterial, COD and residual disinfectant indexes; and lower COD and ammonia concentrations in the influent would mean better downstream quality.

  18. Vortex Stabilized Plasma for Rapid Water Disinfection & Pharmaceutical Degradation

    NASA Astrophysics Data System (ADS)

    Hershcovitch, Ady

    2016-10-01

    Good quality drinking water is dwindling for large segments of the world population. Aggravating the problem is proliferation of antibiotics in the water supply, which give rise to drug resistant pathogens. One option for water supply increase is recycling waste and polluted water by inexpensive, environmentally friendly methods. Presently disinfection uses chemicals and UV radiation. Chemicals are limited by residual toxicity, while UV consumes much electricity. Current methods can remove only certain classes of drugs due to their large variety of physical and chemical properties. Plasmas in water are very attractive for degrading all pharmaceuticals and deactivating pathogens: intense arc current can physically break up any molecular bonds. UV radiation, ozone, etc. generation inside the water volume disinfects. Present utilized plasmas: glow, pulsed arcs are not power efficient; vortex stabilized plasmas are power efficient that can advance water treatment state-of-the-art by orders of magnitude. Proposed techniquefeatures novel components facilitating large diameter vortex stabilized in-water arcs with optimized plasma parameters for maximal UV-C emission; and harvests hydrogen centered by the vortex.

  19. RESEARCH PLAN FOR MICROBIAL PATHOGENS AND DISINFECTION BY-PRODUCTS IN DRINKING WATER

    EPA Science Inventory

    This research plan was developed to describe research needed to support EPA's development of drinking water regulations concerning disinfectants, disinfection by-products (DBPs) and microbial pathogens, focusing on key scientific and technical information needed. The research pl...

  20. RESEARCH PLAN FOR MICROBIAL PATHOGENS AND DISINFECTION BY-PRODUCTS IN DRINKING WATER

    EPA Science Inventory

    This research plan was developed to describe research needed to support EPAs development of drinking water regulations concerning disinfectants, disinfection by-products (DBPs) and microbial pathogens, focusing on key scientific and technical information needed. The research plan...

  1. Evaluation of disinfective potential of reactivated free chlorine in pooled tap water by electrolysis.

    PubMed

    Nakajima, Norihito; Nakano, Takashi; Harada, Fumiue; Taniguchi, Hiromasa; Yokoyama, Isao; Hirose, Jun; Daikoku, Eriko; Sano, Kouichi

    2004-05-01

    Tap water is one of the causative factors of hospital infections. We examined the disinfective potential of electrolysis and mechanism of disinfection, and clarified the disinfective effect of electrolysis on tap water contaminated with bacteria, and discussed its clinical applications. Tap waters artificially contaminated with Pseudomonas aeruginosa, Escherichia coli, Legionella pneumophila, and Staphylococcus aureus could be sterilized by electrolysis at 20-30 mA for 5 min. A high-density suspension (10(6) CFU/ml) of a spore forming bacterium, Bacillus subtilis was not completely sterilized by electrolysis at 50 mA up to 30 min, but a low-density suspension (10(5) CFU/ml) was totally sterilized by electrolysis at 50 mA for 5 min. Electrolyzed P. aeruginosa changed morphologically, that is, there was bleb formation on the cell wall and irregular aggregation of cytoplasmic small granules. Moreover, cytoplasmic enzyme, nitrate reductase, was inactivated by the electrolysis. On the other hand, genomic DNA of the electrolyzed bacteria was not degenerated, therefore, their DNA polymerase activity was not completely inactivated. Consequently, the major agent in electrolysis for bactericidal action was considered to be free chlorine, and the possible bactericidal mechanism was by destruction of bacterial membranes, followed by the aggregation of peripheral cytoplasmic proteins. Electrolysis of tap water for both disinfecting contaminating bacteria and increasing the disinfectant capacity was considered effective with some limitations, particularly against high-density contamination by spore-forming bacteria. In clinical settings, electrolysis of tap water is considered effective to disinfect water for hand washing in operation theatres, and bathing water for immunocompromised hosts.

  2. Reduced Efficiency of Chlorine Disinfection of Naegleria fowleri in a Drinking Water Distribution Biofilm.

    PubMed

    Miller, Haylea C; Wylie, Jason; Dejean, Guillaume; Kaksonen, Anna H; Sutton, David; Braun, Kalan; Puzon, Geoffrey J

    2015-09-15

    Naegleria fowleri associated with biofilm and biological demand water (organic matter suspended in water that consumes disinfectants) sourced from operational drinking water distribution systems (DWDSs) had significantly increased resistance to chlorine disinfection. N. fowleri survived intermittent chlorine dosing of 0.6 mg/L for 7 days in a mixed biofilm from field and laboratory-cultured Escherichia coli strains. However, N. fowleri associated with an attached drinking water distribution biofilm survived more than 30 times (20 mg/L for 3 h) the recommended concentration of chlorine for drinking water. N. fowleri showed considerably more resistance to chlorine when associated with a real field biofilm compared to the mixed laboratory biofilm. This increased resistance is likely due to not only the consumption of disinfectants by the biofilm and the reduced disinfectant penetration into the biofilm but also the composition and microbial community of the biofilm itself. The increased diversity of the field biofilm community likely increased N. fowleri's resistance to chlorine disinfection compared to that of the laboratory-cultured biofilm. Previous research has been conducted in only laboratory scale models of DWDSs and laboratory-cultured biofilms. To the best of our knowledge, this is the first study demonstrating how N. fowleri can persist in a field drinking water distribution biofilm despite chlorination.

  3. Life Cycle Environmental Impacts of Disinfection Technologies Used in Small Drinking Water Systems.

    PubMed

    Jones, Christopher H; Shilling, Elizabeth G; Linden, Karl G; Cook, Sherri M

    2018-03-06

    Small drinking water systems serve a fifth of the U.S. population and rely heavily on disinfection. While chlorine disinfection is common, there is interest in minimizing chemical addition, especially due to carcinogenic disinfection byproducts and chlorine-resistant pathogens, by using ultraviolet technologies; however, the relative, broader environmental impacts of these technologies are not well established, especially in the context of small (<10 000 people) water systems. The objective of this study was to identify environmental trade-offs between chlorine and ultraviolet disinfection via comparative life cycle assessment. The functional unit was the production of 1 m 3 of drinking water to U.S. Treatment included cartridge filtration followed by either chlorine disinfection or ultraviolet disinfection with chlorine residual addition. Environmental performance was evaluated for various chlorine contact zone materials (plastic, concrete, steel), ultraviolet validation factors (1.2 to 4.4), and electricity sources (renewable; U.S. average, high, and low impact grids). Performance was also evaluated when filtration and chlorine residual were not required. From a life cycle assessment perspective, replacing chlorine with UV was preferred only in a limited number of cases (i.e., high pumping pressure but filtration is not required). In all others, chlorine was environmentally preferred, although some contact zone materials and energy sources had an impact on the comparison. Utilities can use these data to inform their disinfection technology selection and operation to minimize environmental and human health impacts.

  4. Rapid water disinfection over a Ag/AgBr/covalent triazine-based framework composite under visible light.

    PubMed

    Li, Liuyi; Li, Xiaofen; Cheng, Zhi; Bi, Jinhong; Liang, Shijing; Zhang, Zizhong; Yu, Yan; Wu, Ling

    2018-05-22

    Development of visible-light-induced and rapid water disinfection is of significant importance. Covalent triazine-based frameworks (CTFs) with pre-designable structures and favorable semiconductive behaviors hold great promise for photocatalytic water disinfection. Here, we report an Ag/AgBr/CTF composite with a layered structure, which serves as an efficient photocatalyst for rapid water disinfection. Water disinfection with >99.99% inactivation of Escherichia coli within 12 min was achieved by using a small amount of Ag/AgBr/CTF under visible light irradiation. The inactivation efficiency of Ag/AgBr/CTF was ∼10 times better than that of bare Ag/AgBr. Rapid water disinfection by the Ag/AgBr/CTF composite mainly results from the greatly improved generation of reactive oxygen species through the synergistic effects among the three components and the affinity of CTF to the cell wall of bacteria.

  5. Nano-silver in drinking water and drinking water sources: stability and influences on disinfection by-product formation.

    PubMed

    Tugulea, A-M; Bérubé, D; Giddings, M; Lemieux, F; Hnatiw, J; Priem, J; Avramescu, M-L

    2014-10-01

    Nano-silver is increasingly used in consumer products from washing machines and refrigerators to devices marketed for the disinfection of drinking water or recreational water. The nano-silver in these products may be released, ending up in surface water bodies which may be used as drinking water sources. Little information is available about the stability of the nano-silver in sources of drinking water, its fate during drinking water disinfection processes, and its interaction with disinfection agents and disinfection by-products (DBPs). This study aims to investigate the stability of nano-silver in drinking water sources and in the finished drinking water when chlorine and chloramines are used for disinfection and to observe changes in the composition of DBPs formed when nano-silver is present in the source water. A dispersion of nano-silver particles (10 nm; PVP-coated) was used to spike untreated Ottawa River water, treated Ottawa River water, organic-free water, and a groundwater at concentrations of 5 mg/L. The diluted dispersions were kept under stirred and non-stirred conditions for up to 9 months and analyzed weekly using UV absorption to assess the stability of the nano-silver particles. In a separate experiment, Ottawa River water containing nano-silver particles (at 0.1 and 1 mg/L concentration, respectively) was disinfected by adding sodium hypochlorite (a chlorinating agent) in sufficient amounts to maintain a free chlorine residual of approximately 0.4 mg/L after 24 h. The disinfected drinking water was then quenched with ascorbic acid and analyzed for 34 neutral DBPs (trihalomethanes, haloacetonitriles, haloacetaldehydes, 1,1 dichloro-2-propanone, 1,1,1 trichloro-2-propanone, chloropicrin, and cyanogen chloride). The results were compared to the profile of DBPs obtained under the same conditions in the absence of nano-silver and in the presence of an equivalent concentration of Ag(+) ions (as AgNO3). The stability of the nano-silver dispersions in

  6. Chloraminated Concentrated Drinking Water for Disinfection Byproduct Mixtures Research: Evaluating Free Chlorine Contact Times

    EPA Science Inventory

    Complex mixtures of disinfection by-products (DBPs) are formed when the disinfectant oxidizes constituents (e.g., natural organic matter (NOM) and organic pollutants) present in the source water. Since 1974, over 600 DBPs have been identified in drinking water, yet a large portio...

  7. Chloramination of Concentrated Drinking Water: Evaluation of Disinfection Byproduct Formation and Dosing Scenarios - Portland

    EPA Science Inventory

    Complex mixtures of disinfection by-products (DBPs) are formed when the disinfectant oxidizes constituents (e.g., natural organic matter (NOM) and organic pollutants) found in the source water. Since 1974, over 600 DBPs have been identified in drinking water. Despite intense iden...

  8. APPROACHING THE TOXICITY OF DISINFECTION BY-PRODUCTS IN DRINKING WATER AS A MIXTURE PROBLEM

    EPA Science Inventory

    Abstract
    Assessment of human health risk from exposure to disinfection by-products (DBPs) in drinking water is of concern because of the wide spread exposure of persons who use disinfected water. Taken as a body of literature, epidemiologic studies on chlorinated drinking ...

  9. Rapid water disinfection using vertically aligned MoS 2 nanofilms and visible light

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Chong; Kong, Desheng; Hsu, Po -Chun

    Here, solar energy is readily available in most climates and can be used for water purification. However, solar disinfection of drinking water (SODIS) mostly relies on ultraviolet light, which represents only 4% of total solar energy, and this leads to slow treatment speed. The development of new materials that can harvest visible light for water disinfection, and speed up solar water purification, is therefore highly desirable. Here, we show that few-layered vertically aligned MoS 2 (FLV-MoS 2) films can be used to harvest the whole spectrum of visible light (~ 50% of solar energy) and achieve highly efficient water disinfection.more » The bandgap of MoS 2 was increased from 1.3 eV to 1.55 eV by decreasing the domain size, which allowed the FLV-MoS 2 to generate reactive oxygen species (ROS) for bacterial inactivation in water. The FLV-MoS 2 showed ~15 times better log inactivation efficiency of indicator bacteria compared to bulk MoS 2, and much faster inactivation of bacteria under both visible light and sunlight illumination compared to widely used TiO 2. Moreover, by using a 5 nm copper film on top of the FLV-MoS 2 as a catalyst to facilitate electron-hole pair separation and promote the generation of ROS, the disinfection rate was further increased 6 fold. With our approach, we achieved water disinfection of >99.999% inactivation of bacteria in 20 minutes with a small amount of material (1.6 mg/L) under simulated visible light.« less

  10. Rapid water disinfection using vertically aligned MoS 2 nanofilms and visible light

    DOE PAGES

    Liu, Chong; Kong, Desheng; Hsu, Po -Chun; ...

    2016-08-15

    Here, solar energy is readily available in most climates and can be used for water purification. However, solar disinfection of drinking water (SODIS) mostly relies on ultraviolet light, which represents only 4% of total solar energy, and this leads to slow treatment speed. The development of new materials that can harvest visible light for water disinfection, and speed up solar water purification, is therefore highly desirable. Here, we show that few-layered vertically aligned MoS 2 (FLV-MoS 2) films can be used to harvest the whole spectrum of visible light (~ 50% of solar energy) and achieve highly efficient water disinfection.more » The bandgap of MoS 2 was increased from 1.3 eV to 1.55 eV by decreasing the domain size, which allowed the FLV-MoS 2 to generate reactive oxygen species (ROS) for bacterial inactivation in water. The FLV-MoS 2 showed ~15 times better log inactivation efficiency of indicator bacteria compared to bulk MoS 2, and much faster inactivation of bacteria under both visible light and sunlight illumination compared to widely used TiO 2. Moreover, by using a 5 nm copper film on top of the FLV-MoS 2 as a catalyst to facilitate electron-hole pair separation and promote the generation of ROS, the disinfection rate was further increased 6 fold. With our approach, we achieved water disinfection of >99.999% inactivation of bacteria in 20 minutes with a small amount of material (1.6 mg/L) under simulated visible light.« less

  11. A randomized controlled trial of household-based flocculant-disinfectant drinking water treatment for diarrhea prevention in rural Guatemala.

    PubMed

    Reller, Megan E; Mendoza, Carlos E; Lopez, M Beatriz; Alvarez, Maricruz; Hoekstra, Robert M; Olson, Christy A; Baier, Kathleen G; Keswick, Bruce H; Luby, Stephen P

    2003-10-01

    We conducted a study to determine if use of a new flocculant-disinfectant home water treatment reduced diarrhea. We randomly assigned 492 rural Guatemalan households to five different water treatment groups: flocculant-disinfectant, flocculant-disinfectant plus a customized vessel, bleach, bleach plus a vessel, and control. During one year of observation, residents of control households had 4.31 episodes of diarrhea per 100 person-weeks, whereas the incidence of diarrhea was 24% lower among residents of households receiving flocculant-disinfectant, 29% lower among those receiving flocculant-disinfectant plus vessel, 25% lower among those receiving bleach, and 12% lower among households receiving bleach plus vessel. In unannounced evaluations of home drinking water, free chlorine was detected in samples from 27% of flocculant-disinfectant households, 35% of flocculant-disinfectant plus vessel households, 35% of bleach households, and 43% of bleach plus vessel households. In a setting where diarrhea was a leading cause of death, intermittent use of home water treatment with flocculant-disinfectant decreased the incidence of diarrhea.

  12. Occurrence and Comparative Toxicity of Haloacetaldehyde Disinfection Byproducts in Drinking Water.

    PubMed

    Jeong, Clara H; Postigo, Cristina; Richardson, Susan D; Simmons, Jane Ellen; Kimura, Susana Y; Mariñas, Benito J; Barcelo, Damia; Liang, Pei; Wagner, Elizabeth D; Plewa, Michael J

    2015-12-01

    The introduction of drinking water disinfection greatly reduced waterborne diseases. However, the reaction between disinfectants and natural organic matter in the source water leads to an unintended consequence, the formation of drinking water disinfection byproducts (DBPs). The haloacetaldehydes (HALs) are the third largest group by weight of identified DBPs in drinking water. The primary objective of this study was to analyze the occurrence and comparative toxicity of the emerging HAL DBPs. A new HAL DBP, iodoacetaldehyde (IAL) was identified. This study provided the first systematic, quantitative comparison of HAL toxicity in Chinese hamster ovary cells. The rank order of HAL cytotoxicity is tribromoacetaldehyde (TBAL) ≈ chloroacetaldehyde (CAL) > dibromoacetaldehyde (DBAL) ≈ bromochloroacetaldehyde (BCAL) ≈ dibromochloroacetaldehyde (DBCAL) > IAL > bromoacetaldehyde (BAL) ≈ bromodichloroacetaldehyde (BDCAL) > dichloroacetaldehyde (DCAL) > trichloroacetaldehyde (TCAL). The HALs were highly cytotoxic compared to other DBP chemical classes. The rank order of HAL genotoxicity is DBAL > CAL ≈ DBCAL > TBAL ≈ BAL > BDCAL>BCAL ≈ DCAL>IAL. TCAL was not genotoxic. Because of their toxicity and abundance, further research is needed to investigate their mode of action to protect the public health and the environment.

  13. Field-testing UV disinfection of drinking water

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gadgil, A.; Drescher, A.; Greene, D.

    A recently invented device, ``UV Waterworks,`` uses ultraviolet (UV) light to disinfect drinking water. Its novel features are: low cost, robust design, rapid disinfection, low electricity use, low maintenance, high flow rate and ability to work with unpressurized water sources. The device could service a community of 1,000 persons, at an annual total cost of less than 10 US cents per person. UV Waterworks has been successfully tested in the laboratory. Limited field trials of an early version of the device were conducted in India in 1994--95. Insights from these trials led to the present design. Extended field trials ofmore » UV Waterworks, initiated in South Africa in February 1997, will be coordinated by the South African Center for Essential Community Services (SACECS), with technical and organizational support from Lawrence Berkeley National Laboratory(LBNL) and the Natural Resources Defense Council (both US). The first of the eight planned sites of the year long trial is an AIDS hospice near Durban. Durban metro Water and LBNL lab-tested a UV Waterworks unit prior to installing it at the hospice in August, 1997. The authors describe the field test plans and preliminary results from Durban.« less

  14. Pre-disinfection columns to improve the performance of the direct electro-disinfection of highly faecal-polluted surface water.

    PubMed

    Isidro, J; Llanos, J; Sáez, C; Lobato, J; Cañizares, P; Rodrigo, M A

    2018-09-15

    This work presents the design and evaluation of a new concept of pre-disinfection treatment that is especially suited for highly polluted surface water and is based on the combination of coagulation-flocculation, lamellar sedimentation and filtration into a single-column unit, in which the interconnection between treatments is an important part of the overall process. The new system, the so-called PREDICO (PRE-DIsinfection Column) system, was built with low-cost consumables from hardware stores (in order to promote in-house construction of the system in poor countries) and was tested with a mixture of 20% raw wastewater and 80% surface water (in order to simulate an extremely bad situation). The results confirmed that the PREDICO system helps to avoid fouling in later electro-disinfection processes and attains a remarkable degree of disinfection (3-4 log units), which supplements the removal of pathogens attained by the electrolytic cell (more than 4 log units). The most important sizing parameters for the PREDICO system are the surface loading rate (SLR) and the hydraulic residence time (HRT); SLR values under 20 cm min -1 and HRT values over 13.6 min in the PREDICO system are suitable to warrant efficient performance of the system. Copyright © 2018 Elsevier Ltd. All rights reserved.

  15. New Water Disinfection Technology for Earth and Space Applications as Part of the NPP Fellowship Research

    NASA Technical Reports Server (NTRS)

    SilvestryRodriquez, Nadia

    2010-01-01

    There is the need for a safe, low energy consuming and compact water disinfection technology to maintain water quality for human consumption. The design of the reactor should present no overheating and a constant temperature, with good electrical and optical performance for a UV water treatment system. The study assessed the use of UVA-LEDs to disinfectant water for MS2 Bacteriophage. The log reduction was sufficient to meet US EPA standards as a secondary disinfectant for maintaining water quality control. The study also explored possible inactivation of Pseudomonas aeruginosa and E. coli.

  16. Optimization of fixed titanium dioxide film on PET bottles and visual indicator for water disinfection

    NASA Astrophysics Data System (ADS)

    Heredia-Munoz, Manuel Antonio

    Water is perhaps the most important resource that sustains human life. According to the World Health Organization (WHO), almost two billion people do not have access to the required water that is needed to satisfy their daily needs and one billion do not have access to clean sources of water for consumption, most of them living in isolated and poor areas around the globe. Poor quality water increases the risk of cholera, typhoid fever and dysentery, and other water-borne illness making this problem a real crisis that humankind is facing. Several water disinfection technologies have been proposed as solutions for this problem. Solar water disinfection using TiO2 coated PET bottles was the alternative that is studied in this work. This technology does not only inactivate bacteria but also disintegrates organic chemicals that can be present in water. The objectives of this work address the optimization of the TiO 2 coated PET bottles technologies. The improvement on the bottle coating process, using two coats of 10% W/V of TiO2 in a solution of vinegar and sodium bicarbonate to form the TiO2 film, the use of a different indigo carmine (1.25 X 10-1mg/pill) concentration in the pill indicator of contamination, the increase of the disinfection rate through shaking the bottles, degradation under intermittent UV radiation and the effect of bottle size on photocatalytic water disinfection were among the most important findings. A new mathematical model that describes better photocatalytic water disinfection in TiO2 coated bottles and simulates water disinfection under different working conditions was another important achievement. These results can now be used to design a strategy for disseminating this technology in areas where it is required and, in that way, generate the greatest positive impact on the people needing safe drinking water.

  17. Evaluation of Electrochemically Generated Potable Water Disinfectants for Use on the International Space Station

    NASA Technical Reports Server (NTRS)

    Rodriquez, Branelle; Anderson, Molly; Adams, Niklas; Vega, Leticia; Botkin, Douglas

    2013-01-01

    Microbial contamination and subsequent growth in spacecraft water systems are constant concerns for missions involving human crews. The current potable water disinfectant for the International Space Station (ISS) is iodine; however, with the end of the Space Shuttle Program, there is a need to develop redundant biocide systems that do not require regular up-mass dependencies. Throughout the course of a year, four different electrochemical systems were investigated as a possible biocide for potable water on the ISS. Research has indicated that a wide variability exists with regards to efficacy in both concentration and exposure time of these disinfectants; therefore, baseline efficacy values were established. This paper describes a series of tests performed to establish optimal concentrations and exposure times for four disinfectants against single and mixed species planktonic and biofilm bacteria. Results of the testing determined whether these electrochemical disinfection systems are able to produce a sufficient amount of chemical in both concentration and volume to act as a biocide for potable water on the ISS.

  18. ORD RESEARCH PLAN FOR MICROBIAL PATHOGENS AND DISINFECTION BY-PRODUCTS IN DRINKING WATER

    EPA Science Inventory

    This research plan was developed to describe research needed to support EPAs development of drinking water regulations concerning disinfectants, disinfection by-products (DBPs) and microbial pathogens, focusing on key scientific and technical information needed. ...

  19. Use of iodine for water disinfection: iodine toxicity and maximum recommended dose.

    PubMed Central

    Backer, H; Hollowell, J

    2000-01-01

    Iodine is an effective, simple, and cost-efficient means of water disinfection for people who vacation, travel, or work in areas where municipal water treatment is not reliable. However, there is considerable controversy about the maximum safe iodine dose and duration of use when iodine is ingested in excess of the recommended daily dietary amount. The major health effect of concern with excess iodine ingestion is thyroid disorders, primarily hypothyroidism with or without iodine-induced goiter. A review of the human trials on the safety of iodine ingestion indicates that neither the maximum recommended dietary dose (2 mg/day) nor the maximum recommended duration of use (3 weeks) has a firm basis. Rather than a clear threshold response level or a linear and temporal dose-response relationship between iodine intake and thyroid function, there appears to be marked individual sensitivity, often resulting from unmasking of underlying thyroid disease. The use of iodine for water disinfection requires a risk-benefit decision based on iodine's benefit as a disinfectant and the changes it induces in thyroid physiology. By using appropriate disinfection techniques and monitoring thyroid function, most people can use iodine for water treatment over a prolonged period of time. PMID:10964787

  20. Solar water disinfection (SODIS): a review from bench-top to roof-top.

    PubMed

    McGuigan, Kevin G; Conroy, Ronán M; Mosler, Hans-Joachim; du Preez, Martella; Ubomba-Jaswa, Eunice; Fernandez-Ibañez, Pilar

    2012-10-15

    Solar water disinfection (SODIS) has been known for more than 30 years. The technique consists of placing water into transparent plastic or glass containers (normally 2L PET beverage bottles) which are then exposed to the sun. Exposure times vary from 6 to depending on the intensity of sunlight and sensitivity of the pathogens. Its germicidal effect is based on the combined effect of thermal heating of solar light and UV radiation. It has been repeatedly shown to be effective for eliminating microbial pathogens and reduce diarrhoeal morbidity including cholera. Since 1980 much research has been carried out to investigate the mechanisms of solar radiation induced cell death in water and possible enhancement technologies to make it faster and safer. Since SODIS is simple to use and inexpensive, the method has spread throughout the developing world and is in daily use in more than 50 countries in Asia, Latin America, and Africa. More than 5 million people disinfect their drinking water with the solar disinfection (SODIS) technique. This review attempts to revise all relevant knowledge about solar disinfection from microbiological issues, laboratory research, solar testing, up to and including real application studies, limitations, factors influencing adoption of the technique and health impact. Copyright © 2012 Elsevier B.V. All rights reserved.

  1. [Genotoxicity of drinking water during chlorine and chloramine disinfection and the influence of disinfection conditions using the umu-test].

    PubMed

    Liu, Qing; Zhang, Li-Ping; Liu, Wen-Jun; Nie, Xue-Biao; Zhang, Su-Xia; Zhang, Shun

    2010-01-01

    In this study, the effects of disinfectant dosage, reaction time and the ratio of Cl2 to N of disinfectant on genotoxicity of effluent of ozone-biological activated carbon (O3-BAC) during chlorine or chloramine disinfection were investigated using umu-test. It was found that, the genotoxicity of effluent of O3-BAC before disinfection ranged from 20-70 ng/L, and it increased after disinfection by chlorine or chloramines. With the same reaction time(24 h), genotoxicity after chlorination (40-95 ng/L) was higher than that after chloramination (20-40 ng/L) under same initial dosage. For chlorination, with initial dosage increasing from 0 mg/L to 10 mg/L, genotoxicity increased firstly, and got the maximum value at about 0.5-1 mg/L dosage, then decreased and got the minimum value at about 3-5 mg/L dosage, and finally increased again. For chloramination, genotoxicity didn't change that much. With the dosage of 3 mg/L and reaction time increasing from 0 h to 72 h, no matter for chlorine or chloramines disinfection, genotoxicity of effluent of O3-BAC both increased firstly, and got the maximum value at about 2 h, then decreased and got the minimum value at about 18 h, and finally increased again, and genotoxicity after chlorine disinfection (83-120 ng/L) was higher than that after chloramines disinfection (20-62 ng/L) under same reaction time. Further more, effects of the different ratios of Cl2 to N of disinfectant on genotoxicity of effluent of O3-BAC were also studied. Results of this study demonstrate that under test conditions, chloramine disinfection is safer than chlorine disinfection in the aspect of genotoxicity for drinking water, and the changes of genotoxicity are different from those of total HAAs.

  2. Rapid water disinfection using vertically aligned MoS2 nanofilms and visible light

    NASA Astrophysics Data System (ADS)

    Liu, Chong; Kong, Desheng; Hsu, Po-Chun; Yuan, Hongtao; Lee, Hyun-Wook; Liu, Yayuan; Wang, Haotian; Wang, Shuang; Yan, Kai; Lin, Dingchang; Maraccini, Peter A.; Parker, Kimberly M.; Boehm, Alexandria B.; Cui, Yi

    2016-12-01

    Solar energy is readily available in most climates and can be used for water purification. However, solar disinfection of drinking water mostly relies on ultraviolet light, which represents only 4% of the total solar energy, and this leads to a slow treatment speed. Therefore, the development of new materials that can harvest visible light for water disinfection, and so speed up solar water purification, is highly desirable. Here we show that few-layered vertically aligned MoS2 (FLV-MoS2) films can be used to harvest the whole spectrum of visible light (∼50% of solar energy) and achieve highly efficient water disinfection. The bandgap of MoS2 was increased from 1.3 to 1.55 eV by decreasing the domain size, which allowed the FLV-MoS2 to generate reactive oxygen species (ROS) for bacterial inactivation in the water. The FLV-MoS2 showed a ∼15 times better log inactivation efficiency of the indicator bacteria compared with that of bulk MoS2, and a much faster inactivation of bacteria under both visible light and sunlight illumination compared with the widely used TiO2. Moreover, by using a 5 nm copper film on top of the FLV-MoS2 as a catalyst to facilitate electron-hole pair separation and promote the generation of ROS, the disinfection rate was increased a further sixfold. With our approach, we achieved water disinfection of >99.999% inactivation of bacteria in 20 min with a small amount of material (1.6 mg l-1) under simulated visible light.

  3. Effects of Pumping and Well Disinfection on Arsenic Release to Well Water

    NASA Astrophysics Data System (ADS)

    Gotkowitz, M.; Shelobolina, E.; Roden, E. E.

    2007-12-01

    In areas of northeastern Wisconsin, arsenic-bearing sulfides and iron oxides are distributed throughout a sandstone aquifer used for domestic water supplies. Aqueous arsenic concentrations exceed 10 μg/L in approximately 20% of wells in this region. These wells are often subjected to in situ chlorine disinfection to control nuisance or pathogenic bacteria. Field-based experiments investigating the effects of pumping and well disinfection showed that under non-pumping conditions, the geochemical environment in a domestic well is strongly reducing. Aqueous arsenic ranged from 10 to 18 μg/L, and the number of all tested groups of microorganisms (As(III)-reducing, Fe(III)-reducing, sulfate-reducing, As(V)-oxidizing, and aerobic microorganisms) increased 0.3 to 2.4 orders of magnitude in the well water under non-pumping conditions. The diverse populations of anaerobic and aerobic microorganisms reflect the complexity of the borehole environment. The number of Fe(III)-reducing bacteria correlates with As(III) concentrations, suggesting that microbially- facilitated reduction of iron (hydr)oxides contributes to the relatively rapid rise in aqueous arsenic observed under non-pumping conditions. Pumping the well introduces up to 1 mg/L of oxygen into the well water. The change in redox imposed by pumping decreased the number of anaerobic As(III)-reducing, Fe(III)-reducing, and sulfate-reducing microorganisms by 1 to 1.7 orders of magnitude. Aqueous arsenic also decreased during pumping (<7 μg/L), indicating that low-arsenic groundwater recharges the well. Chlorine disinfection produced strongly oxidizing conditions in the well for one hour. Treatment reduced the numbers of all microorganisms tested, but the populations recovered within three weeks. This suggests that either fresh formation water re-inoculated the well or that biofilm and scale in the well harbored some microbes from the disinfectant. Post-disinfection arsenic concentrations were similar to those measured

  4. COMPARATIVE RISK DILEMNAS IN DRINKING WATER DISINFECTION [EDITORIAL

    EPA Science Inventory

    Disinfection of drinking water supplies has been one of the most succesful public health interventions of the twentieth century. It has virtually eliminated outbreaks of serious waterborne infectious diseases, such as cholera and typhoid. there are still, however, an average of...

  5. Can CabECO® technology be used for the disinfection of highly faecal-polluted surface water?

    PubMed

    Isidro, Julia; Llanos, Javier; Sáez, Cristina; Brackemeyer, Dirk; Cañizares, Pablo; Matthee, Thorsten; Rodrigo, Manuel A

    2018-06-18

    In this work, the disinfection of highly faecal-polluted surface water was studied using a new electrochemical cell (CabECO ® cell, manufactured by CONDIAS) specifically designed to produce ozone in water with very low conductivity. The disinfection tests were carried out in a discontinuous mode to evaluate the influence of the electrode current charge passed. The effect of the current density was also studied in order to optimize the disinfection conditions and to simultaneously prevent the formation of undesirable by-products (chlorates and perchlorates) during the electrolysis. The results demonstrate that this technology is robust and efficient, and it can suitably disinfect water. During electrolysis, the chloride contained in the water was oxidized to hypochlorite, and this compound was combined with ammonia to form chloramines. Both hypochlorite and chloramines (formed by the well-known break point reaction) promoted persistent disinfection and seemed to be mainly responsible for the disinfection attained during the electrochemical process. Chlorate and perchlorate could also be produced, although the low concentrations of chloride in the tested water made them irrelevant. The removal of the total organic carbon under the applied operating conditions was not very efficient (although it reached 50% in 2 h) and the production of trihalomethanes was very low, below 100 ppb for all tests. Copyright © 2018 Elsevier Ltd. All rights reserved.

  6. Testing the Carcinogenic Potential of Water Disinfectant Byproducts in a Human Colon Mucosal Culture System

    EPA Science Inventory

    Epidemiological studies have linked the consumption of disinfected surface waters to an increased risk of colorectal cancer. Approximately 600 disinfection byproducts (DBPs) have been identified for a number of disinfectants currently in use. An in-depth mechanism-based structure...

  7. DETERMINATION OF NEWLY IDENTIFIED DISINFECTION BY-PRODUCTS IN DRINKING WATER

    EPA Science Inventory

    The Metropolitan Water District of Southern California (MWDSC) is investigating the occurrence of 39 newly identified disinfection by-products (DBPs)-which were not included in the Information Collection Rule (ICR)-in drinking waters. Halomethanes (HMs), haloacetonitriles (HANs),...

  8. Water disinfection: A relationship between ozone and aldehyde production

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gilli, G.; Scursatone, E.; Palin, L.

    In the water potabilization plant of Turin city (Italy), the oxidation process is carried out with ozone. Due to its well-known insufficient performance, it is necessary to add alternative oxidants (hypochlorite ion and chlorine dioxide). In this paper, the authors discuss the formation of linear carbonyl groups during surface water treatment in Turni. The results obtained in the field confirm the synthesis of some aliphatic carbonyl compounds of low molecular weight. This phenomenon happens preeminently during the ozone disinfection process and, secondarily, during the other disinfection processes. Experimental results show that, in this last event, chlorine reacts with organic substances,more » and in a second moment, after organics consumption, if chlorine is still in a sufficient concentration, oxidizing them.« less

  9. Microbial disinfection of water with endotoxin degradation by photocatalysis using Ag@TiO2 core shell nanoparticles.

    PubMed

    S, Sreeja; K, Vidya Shetty

    2016-09-01

    The studies on photocatalytic disinfection of water contaminated with Escherichia coli using Ag core and TiO2 shell (Ag@TiO2) nanoparticles under UV irradiation showed that these nanoparticles are very efficient in water disinfection both in their free and immobilised form. Complete disinfection of 40 × 10(8) CFU/mL could be achieved in 60 min with 0.4 g/L catalyst loading and in 35 min with 1 g/L catalyst loading. Ag@TiO2 nanoparticles were found to be superior to TiO2 nanoparticles in photocatalytic disinfection of water. Kinetics of disinfection followed Chick's law, and the pseudo-first-order rate constant was 0.0168 min(-1) for a catalyst loading of 0.1 g/L. Disinfection of water and degradation of endotoxins (harmful disinfection residual) occurred simultaneously during photocatalysis thereby making the treated water safe for use. Endotoxin degradation showed a shifting order of kinetics. The rate of photocatalysis with nanoparticles immobilised in cellulose acetate film was marginally lower as compared to that of free nanoparticles. Negligible Ag ion leakage and re-growth of cells post-photo-catalytic treatment of water confirmed that complete disintegration of E. coli occurred during photocatalysis making the treated water safe for use. Therefore, Ag@TiO2 nanoparticles have a potential for large-scale application in drinking water treatment plants and household purification units.

  10. Stability and effectiveness of chlorine disinfectants in water distribution systems.

    PubMed

    Olivieri, V P; Snead, M C; Krusé, C W; Kawata, K

    1986-11-01

    A test system for water distribution was used to evaluate the stability and effectiveness of three residual disinfectants--free chlorine, combined chlorine, and chlorine dioxide--when challenged with a sewage contaminant. The test distribution system consisted of the street main and internal plumbing for two barracks at Fort George G. Meade, MD. To the existing pipe network, 152 m (500 ft) of 13-mm (0.5 in.) copper pipe were added for sampling, and 60 m (200 ft) of 2.54-cm (1.0 in.) plastic pipe were added for circulation. The levels of residual disinfectants tested were 0.2 mg/L and 1.0 mg/L as available chlorine. In the absence of a disinfectant residual, microorganisms in the sewage contaminant were consistently recovered at high levels. The presence of any disinfectant residual reduced the microorganism level and frequency of occurrence at the consumer's tap. Free chlorine was the most effective residual disinfectant and may serve as a marker or flag in the distribution network. Free chlorine and chlorine dioxide were the least stable in the pipe network. The loss of disinfectant in the pipe network followed first-order kinetics. The half-life determined in static tests for free chlorine, chlorine dioxide, and combined chlorine was 140, 93, and 1680 min.

  11. Stability and effectiveness of chlorine disinfectants in water distribution systems.

    PubMed Central

    Olivieri, V P; Snead, M C; Krusé, C W; Kawata, K

    1986-01-01

    A test system for water distribution was used to evaluate the stability and effectiveness of three residual disinfectants--free chlorine, combined chlorine, and chlorine dioxide--when challenged with a sewage contaminant. The test distribution system consisted of the street main and internal plumbing for two barracks at Fort George G. Meade, MD. To the existing pipe network, 152 m (500 ft) of 13-mm (0.5 in.) copper pipe were added for sampling, and 60 m (200 ft) of 2.54-cm (1.0 in.) plastic pipe were added for circulation. The levels of residual disinfectants tested were 0.2 mg/L and 1.0 mg/L as available chlorine. In the absence of a disinfectant residual, microorganisms in the sewage contaminant were consistently recovered at high levels. The presence of any disinfectant residual reduced the microorganism level and frequency of occurrence at the consumer's tap. Free chlorine was the most effective residual disinfectant and may serve as a marker or flag in the distribution network. Free chlorine and chlorine dioxide were the least stable in the pipe network. The loss of disinfectant in the pipe network followed first-order kinetics. The half-life determined in static tests for free chlorine, chlorine dioxide, and combined chlorine was 140, 93, and 1680 min. PMID:3028767

  12. Chlorine dioxide as a post-disinfectant for Dutch drinking water.

    PubMed

    Wondergem, E; van Dijk-Looijaard, A M

    1991-02-01

    Chlorine dioxide has some important advantages over chlorine with respect to water quality (no formation of trihalomethanes, no impairment of taste and no odor) and stability when used for oxidation/disinfection of drinking water. In this paper, results are presented of experiments into the consumption and reaction kinetics of chlorine dioxide in a number of (drinking) waters in The Netherlands. It was found that chlorine dioxide consumption is related to the dissolved oxygen content (DOC) of the water and the reaction time. Water samples from a plant that applied ozonation and activated carbon filtration had a very low chlorine dioxide consumption. Other water quality parameters, including pH and CO3(2-), did not have any influence on consumption. The temporary advised Dutch guidelines of 0.2 mg l-1 (dosage) is sufficient for activated carbon treated water. For other Dutch drinking waters, however, none of the 0.2 mg l-1 chlorine dioxide remained after a reaction time of 10 min, as was also found for the water of Dutch pumping stations where chlorine dioxide is at present used for disinfection.

  13. High-Performance Capacitive Deionization Disinfection of Water with Graphene Oxide-graft-Quaternized Chitosan Nanohybrid Electrode Coating.

    PubMed

    Wang, Yilei; El-Deen, Ahmed G; Li, Peng; Oh, Bernice H L; Guo, Zanru; Khin, Mya Mya; Vikhe, Yogesh S; Wang, Jing; Hu, Rebecca G; Boom, Remko M; Kline, Kimberly A; Becker, David L; Duan, Hongwei; Chan-Park, Mary B

    2015-10-27

    Water disinfection materials should ideally be broad-spectrum-active, nonleachable, and noncontaminating to the liquid needing sterilization. Herein, we demonstrate a high-performance capacitive deionization disinfection (CDID) electrode made by coating an activated carbon (AC) electrode with cationic nanohybrids of graphene oxide-graft-quaternized chitosan (GO-QC). Our GO-QC/AC CDID electrode can achieve at least 99.9999% killing (i.e., 6 log reduction) of Escherichia coli in water flowing continuously through the CDID cell. Without the GO-QC coating, the AC electrode alone cannot kill the bacteria and adsorbs a much smaller fraction (<82.8 ± 1.8%) of E. coli from the same biocontaminated water. Our CDID process consists of alternating cycles of water disinfection followed by electrode regeneration, each a few minutes duration, so that this water disinfection process can be continuous and it only needs a small electrode voltage (2 V). With a typical brackish water biocontamination (with 10(4) CFU mL(-1) bacteria), the GO-QC/AC electrodes can kill 99.99% of the E. coli in water for 5 h. The disinfecting GO-QC is securely attached on the AC electrode surface, so that it is noncontaminating to water, unlike many other chemicals used today. The GO-QC nanohybrids have excellent intrinsic antimicrobial properties in suspension form. Further, the GO component contributes toward the needed surface conductivity of the CDID electrode. This CDID process offers an economical method toward ultrafast, contaminant-free, and continuous killing of bacteria in biocontaminated water. The proposed strategy introduces a green in situ disinfectant approach for water purification.

  14. Innovative Approach to Validation of Ultraviolet (UV) Reactors for Disinfection in Drinking Water Systems - presentation

    EPA Science Inventory

    UV disinfection is an effective process for inactivating many microbial pathogens found in source waters with the potential as stand-alone treatment or in combination with other disinfectants. For surface and groundwater sourced drinking water applications, the U.S. Environmental...

  15. 40 CFR 141.72 - Disinfection.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 23 2014-07-01 2014-07-01 false Disinfection. 141.72 Section 141.72... PRIMARY DRINKING WATER REGULATIONS Filtration and Disinfection § 141.72 Disinfection. A public water... disinfection treatment specified in paragraph (a) of this section beginning December 30, 1991, unless the State...

  16. 40 CFR 141.72 - Disinfection.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 24 2012-07-01 2012-07-01 false Disinfection. 141.72 Section 141.72... PRIMARY DRINKING WATER REGULATIONS Filtration and Disinfection § 141.72 Disinfection. A public water... disinfection treatment specified in paragraph (a) of this section beginning December 30, 1991, unless the State...

  17. DRINKING WATER DISINFECTION BYPRODUCTS AND DURATION OF GESTATION

    EPA Science Inventory

    Recent studies of drinking water disinfection by-products (DBPs) suggest high exposure decreases risk of preterm birth. We examined this association with total trihalomethane (TTHM) and five haloacetic acids (HAA5) among 2,041 women in a prospective pregnancy study conducted from...

  18. Disinfection by-products in drinking water

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Craun, G.F.

    Many organic contaminants have been identified in drinking water, some of which are introduced during treatment. Whereas chlorination of drinking water prevents the transmission of infectious diseases, free chlorine can react with precursors in water, such as humic and fulvic acids, to produce halogenated and oxidized by-products. Many disinfection by-products have been detected, including haloketones, haloaldehydes, haloacids, haloacetonitrile, cyanogen chloride, chlorophenols, chloropicrin, and chlorinated hydroxyfuranones (i.e., MX and E-MX). A survey of 35 water facilities showed that trihalomethanes were the largest class of by-products (median 39 {mu}g/{ell}) and haloacetic acids the next most significant (median 19 {mu}g/{ell}). Cyanogen chloride wasmore » preferentially produced in chloraminated water supplies, and formaldehyde and acetaldehyde were identified as by-products of ozonation.« less

  19. Reducing diarrhoea in Guatemalan children: randomized controlled trial of flocculant-disinfectant for drinking-water.

    PubMed

    Chiller, Tom M; Mendoza, Carlos E; Lopez, M Beatriz; Alvarez, Maricruz; Hoekstra, Robert M; Keswick, Bruce H; Luby, Stephen P

    2006-01-01

    To examine the effect of a new point-of-use treatment for drinking-water, a commercially developed flocculant-disinfectant, on the prevalence of diarrhoea in children. We conducted a randomized controlled trial among 514 rural Guatemalan households, divided into 42 neighbourhood clusters, for 13 weeks, from 4 November 2002 through 31 January 2003. Clusters assigned to water treatment with the flocculant-disinfectant were compared with those using their usual water-handling practices. The longitudinal prevalence of diarrhoea was calculated as the proportion of total days with diarrhoea divided by the total number of days of observation. The prevalence of diarrhoea was compared using the Wilcoxon rank-sum test. The 1702 people in households receiving the disinfectant had a prevalence of diarrhoea that was 40% lower than that among the 1699 people using standard water-handling practices (0.9% versus 1.5%; P = 0.001). In households using the flocculant-disinfectant, children < 1 year of age had a 39% lower prevalence of diarrhoea than those in households using their standard practices (3.7% versus 6.0%; P = 0.005). In settings where families rarely treat drinking-water, we introduced a novel flocculant-disinfectant that reduced the longitudinal prevalence of diarrhoea, especially among children aged < 1 year, among whom diarrhoea has been strongly associated with mortality. Successful introduction and use of this product could contribute to preventing diarrhoeal disease globally.

  20. Why Do People Stop Treating Contaminated Drinking Water with Solar Water Disinfection (SODIS)?

    ERIC Educational Resources Information Center

    Tamas, Andrea; Mosler, Hans-Joachim

    2011-01-01

    Solar Water Disinfection (SODIS) is a simple method designed to treat microbiologically contaminated drinking water at household level. This article characterizes relapse behavior in comparison with continued SODIS use after a 7-month nonpromotion period. In addition, different subtypes among relapsers and continuers were assumed to diverge mainly…

  1. ANALYTICAL METHODS FOR WATER DISINFECTION BYPRODUCTS IN FOODS AND BEVERAGES

    EPA Science Inventory

    The determination of exposure to drinking water disinfection byproducts (DBPs) requires an understanding of how drinking water comes into contact with human through multiple pathways. In order to facilitate the investigation of human exposure to DBPs via foods and beverages, anal...

  2. Models for predicting disinfection byproduct (DBP) formation in drinking waters: a chronological review.

    PubMed

    Chowdhury, Shakhawat; Champagne, Pascale; McLellan, P James

    2009-07-01

    Disinfection for the supply of safe drinking water forms a variety of known and unknown byproducts through reactions between the disinfectants and natural organic matter. Chronic exposure to disinfection byproducts through the ingestion of drinking water, inhalation and dermal contact during regular indoor activities (e.g., showering, bathing, cooking) may pose cancer and non-cancer risks to human health. Since their discovery in drinking water in 1974, numerous studies have presented models to predict DBP formation in drinking water. To date, more than 48 scientific publications have reported 118 models to predict DBP formation in drinking waters. These models were developed through laboratory and field-scale experiments using raw, pretreated and synthetic waters. This paper aims to review DBP predictive models, analyze the model variables, assess the model advantages and limitations, and to determine their applicability to different water supply systems. The paper identifies the current challenges and future research needs to better control DBP formation. Finally, important directions for future research are recommended to protect human health and to follow the best management practices.

  3. Chlorine Disinfection of Atypical Mycobacteria Isolated from a Water Distribution System

    PubMed Central

    Le Dantec, Corinne; Duguet, Jean-Pierre; Montiel, Antoine; Dumoutier, Nadine; Dubrou, Sylvie; Vincent, Véronique

    2002-01-01

    We studied the resistance of various mycobacteria isolated from a water distribution system to chlorine. Chlorine disinfection efficiency is expressed as the coefficient of lethality (liters per minute per milligram) as follows: Mycobacterium fortuitum (0.02) > M. chelonae (0.03) > M. gordonae (0.09) > M. aurum (0.19). For a C · t value (product of the disinfectant concentration and contact time) of 60 mg · min · liter−1, frequently used in water treatment lines, chlorine disinfection inactivates over 4 log units of M. gordonae and 1.5 log units of M. fortuitum or M. chelonae. C · t values determined under similar conditions show that even the most susceptible species, M. aurum and M. gordonae, are 100 and 330 times more resistant to chlorine than Escherichia coli. We also investigated the effects of different parameters (medium, pH, and temperature) on chlorine disinfection in a chlorine-resistant M. gordonae model. Our experimental results follow the Arrhenius equation, allowing the inactivation rate to be predicted at different temperatures. Our results show that M. gordonae is more resistant to chlorine in low-nutrient media, such as those encountered in water, and that an increase in temperature (from 4°C to 25°C) and a decrease in pH result in better inactivation. PMID:11872446

  4. A comparison of disinfection by-products formation during sequential or simultaneous disinfection of surface waters with chlorine dioxide and chlor(am)ine.

    PubMed

    Shi, Yanwei; Ling, Wencui; Qiang, Zhimin

    2013-01-01

    The effect of chlorine dioxide (ClO2) oxidation on the formation of disinfection by-products (DBPs) during sequential (ClO2 pre-oxidation for 30 min) and simultaneous disinfection processes with free chlorine (FC) or monochloramine (MCA) was investigated. The formation of DBPs from synthetic humic acid (HA) water and three natural surface waters containing low bromide levels (11-27 microg/L) was comparatively examined in the FC-based (single FC, sequential ClO2-FC, and simultaneous ClO2/FC) and MCA-based (single MCA, ClO2-MCA, and ClO2/MCA) disinfection processes. The results showed that much more DBPs were formed from the synthetic HA water than from the three natural surface waters with comparative levels of dissolved organic carbon. In the FC-based processes, ClO2 oxidation could reduce trihalomethanes (THMs) by 27-35% and haloacetic acids (HAAs) by 14-22% in the three natural surface waters, but increased THMs by 19% and HAAs by 31% in the synthetic HA water after an FC contact time of 48 h. In the MCA-based processes, similar trends were observed although DBPs were produced at a much lower level. There was an insignificant difference in DBPs formation between the sequential and simultaneous processes. The presence of a high level of bromide (320 microg/L) remarkably promoted the DBPs formation in the FC-based processes. Therefore, the simultaneous disinfection process of ClO2/MCA is recommended particularly for waters with a high bromide level.

  5. Giardia cyst destruction: effectiveness of six small-quantity water disinfection methods.

    PubMed

    Jarroll, E L; Bingham, A K; Meyer, E A

    1980-01-01

    None of the available chemical methods for disinfecting drinking water has ever been tested for its ability to destory Giardia cysts. We tested the ability of six such methods to act against Giardia, using excystation as the criterion of viability. Two water qualities (cloudy and clear) and two temperatures (3 and 20 degrees C) were tested. At 20 degrees C, using cloudy and clear water, all of the method proved completely effective. However, at 3 degrees C, in cloudy water one method ("saturated" iodine) was less than completely effective, and in clear water four methods (bleach, Globaline, tincture of iodine and "saturated" iodine) failed to destory all of the cysts. The failure of these methods appears to be related to either an insufficient halogen residual or contact time. This study underlines the importance of considering water temperature when employing halogen disinfection methods.

  6. COMPONENT-BASED AND WHOLE-MIXTURE TECHNIQUES FOR ADDRESSING THE TOXICITY OF DRINKING WATER DISINFECTION BYPRODUCT MIXTURES

    EPA Science Inventory

    ABSTRACT

    Chemical disinfection of water is of direct public health benefit as it results in decreased waterborne illness. The chemicals used to disinfect water react with naturally occurring organic matter and bromide in the source water, resulting in the formation of a m...

  7. Disinfectant Penetration into Nitrifying Drinking Water Distribution System Biofilm Using Microelectrodes

    EPA Science Inventory

    Nitrification within drinking water distribution systems reduces water quality, causes difficulties maintaining adequate disinfectant residual, and poses public health concerns including exposure to nitrite, nitrate, and opportunistic pathogenic microorganisms. Monochloramine is...

  8. Effect of disinfectant, water age, and pipe materials on bacterial and eukaryotic community structure in drinking water biofilm.

    PubMed

    Wang, Hong; Masters, Sheldon; Edwards, Marc A; Falkinham, Joseph O; Pruden, Amy

    2014-01-01

    Availability of safe, pathogen-free drinking water is vital to public health; however, it is impossible to deliver sterile drinking water to consumers. Recent microbiome research is bringing new understanding to the true extent and diversity of microbes that inhabit water distribution systems. The purpose of this study was to determine how water chemistry in main distribution lines shape the microbiome in drinking water biofilms and to explore potential associations between opportunistic pathogens and indigenous drinking water microbes. Effects of disinfectant (chloramines, chlorine), water age (2.3 days, 5.7 days), and pipe material (cement, iron, PVC) were compared in parallel triplicate simulated water distribution systems. Pyrosequencing was employed to characterize bacteria and terminal restriction fragment polymorphism was used to profile both bacteria and eukaryotes inhabiting pipe biofilms. Disinfectant and water age were both observed to be strong factors in shaping bacterial and eukaryotic community structures. Pipe material only influenced the bacterial community structure (ANOSIM test, P < 0.05). Interactive effects of disinfectant, pipe material, and water age on both bacteria and eukaryotes were noted. Disinfectant concentration had the strongest effect on bacteria, while dissolved oxygen appeared to be a major driver for eukaryotes (BEST test). Several correlations of similarity metrics among populations of bacteria, eukaryotes, and opportunistic pathogens, as well as one significant association between mycobacterial and proteobacterial operational taxonomic units, provides insight into means by which manipulating the microbiome may lead to new avenues for limiting the growth of opportunistic pathogens (e.g., Legionella) or other nuisance organisms (e.g., nitrifiers).

  9. HUMAN EXPOSURE TO WATER DISINFECTION BY-PRODUCTS VIA FOODS AND BEVERAGES

    EPA Science Inventory

    The ingestion of tap water is a major route of exposure to water disinfection byproducts (DBPs), including haloacetonitriles, haloketones, and haloacetic acids. A potentially significant alternate route of exposure is through the consumption of beverages prepared with tap water ...

  10. Identifying Carcinogenic Potentials of Drinking Water Disinfection Byproducts using Normal Human Colonocyte Cultures

    EPA Science Inventory

    Epidemiological studies have linked the consumption of disinfected surface waters to an increased risk of colorectal cancer. Approximately 600 byproducts (DBPs) have been identified for the major disinfectants currently in use and represent less than half of the total organic car...

  11. Evaluation of Electrochemically Generated Potable Water Disinfectants for Use on the International Space Station

    NASA Technical Reports Server (NTRS)

    Rodriquez, Branelle; Anderson, Molly; Anderson, Molly; Adam, Niklas; Vega, Leticia; Modica, Catherine; Bodkin, Douglas

    2012-01-01

    Microbial contamination and subsequent growth in spacecraft water systems are constant concerns for missions involving human crews. The current potable water disinfectant for the International Space Station (ISS) is iodine; however, with the end of the Space Shuttle program, there is a need to develop redundant biocide systems that do not require regular up ]mass dependencies. Throughout the course of a year, four different electrochemical systems were investigated as a possible biocide for potable water on the ISS. Research has indicated that there is a wide variability with regards to efficacy in both concentration and exposure time of these disinfectants, therefore baseline efficacy values were established. This paper describes a series of tests performed in order to establish optimal concentrations and exposure times for four disinfectants against single and mixed species planktonic and biofilm bacteria. Results of the testing determined whether these electrochemical disinfection systems are able to produce a sufficient amount of chemical in both concentration and volume to act as a biocide for potable water on ISS.

  12. ANALYTICAL METHODS FOR WATER DISINFECTION BY-PRODUCTS IN FOODS AND BEVERAGES

    EPA Science Inventory

    The determination of exposure to drinking water disinfection byproducts (DBPs) requires an understanding of how drinking waters come into contact with the human through multiple pathways. The most significant pathway is the ingestion of drinking water. However, ingestion can oc...

  13. Tertiary treatment using microfiltration and UV disinfection for water reclamation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jolis, D.; Hirano, R.; Pitt, P.

    Microfiltration and UV disinfection are two alternative technologies for water reclamation. The results of a pilot study combining these two processes are presented. In addition to producing filtrate turbidites averaging 0.06 nephelometric turbidity units, microfiltration was an effective barrier to pathogens, demonstrating average log reductions of 4.5 for total coliforms and 2.9 for MS2 bacteriophage. Ultraviolet disinfection following microfiltration reliably met the California Wastewater Reclamation Criteria (Title 22) total coliform standard of 2.2 colony-forming units/100 mL at a UV dose of 450 J/m{sup 2}. The MS2 bacteriophage standard, which requires a 5-log reduction, was achieved by microfiltration and a UVmore » dose of 880 J/m{sup 2}. A model of the kinetics of inactivation of MS2 bacteriophage was used in further analysis of disinfection data. The model indicated that considerable backmixing occurred in the pilot UV disinfection unit, and observed UV doses could be reduced with improved hydraulics.« less

  14. Safety and durability of low-density polyethylene bags in solar water disinfection applications.

    PubMed

    Danwittayakul, Supamas; Songngam, Supachai; Fhulua, Tipawan; Muangkasem, Panida; Sukkasi, Sittha

    2017-08-01

    Solar water disinfection (SODIS) is a simple point-of-use process that uses sunlight to disinfect water for drinking. Polyethylene terephthalate (PET) bottles are typically used as water containers for SODIS, but a new SODIS container design has recently been developed with low-density polyethylene (LDPE) bags and can overcome the drawbacks of PET bottles. Two nesting layers of LDPE bags are used in the new design: the inner layer containing the water to be disinfected and the outer one creating air insulation to minimize heat loss from the water to the surroundings. This work investigated the degradation of LDPE bags used in the new design in actual SODIS conditions over a period of 12 weeks. The degradation of the LDPE bags was investigated weekly using a scanning electron microscope, Fourier transform infrared spectroscopy, ultraviolet-visible spectrophotometer, and tensile strength tester. It was found that the LDPE bags gradually degraded under the sunlight due to photo-oxidation reactions, especially in the outer bags, which were directly exposed to the sun and surroundings, leading to the reduction of light transmittance (by 11% at 300 nm) and tensile strength (by 33%). In addition, possible leaching of organic compounds into the water contained in the inner bags was examined using gas chromatography-mass spectrometer. 2,4-Di-tert-butylphenol was found in some SODIS water samples as well as the as-received water samples, in the concentration range of 1-4 μg/L, which passes the Environmental Protection Agency Drinking Water Guidance on Disinfection By-Products.

  15. Carbon nanotubes as antimicrobial agents for water disinfection and pathogen control.

    PubMed

    Liu, Dan; Mao, Yiqin; Ding, Lijun

    2018-04-01

    Waterborne diseases significantly affect human health and are responsible for high mortality rates worldwide. Antibiotics have been known for decades for treatment of bacterial strains and their overuse and irrational applications are causing increasing bacteria resistance. Therefore, there is a strong need to find alternative ways for efficient water disinfection and microbial control. Carbon nanotubes (CNTs) have demonstrated strong antimicrobial properties due to their remarkable structure. This paper reviews the antimicrobial properties of CNTs, discusses diverse mechanisms of action against microorganisms as well as their applicability for water disinfection and microbial control. Safety concerns, challenges of CNTs as antimicrobial agents and future opportunities for their application in the water remediation process are also highlighted.

  16. TRIBROMOPYRROLE, BROMINATED ACIDS, AND OTHER DISINFECTION BYPRODUCTS PRODUCED BY DISINFECTION OF DRINKING WATER RICH IN BROMIDE

    EPA Science Inventory

    Using gas chromatography/mass spectrometry (GC/MS), we investigated the formation of disinfection byproducts (DBPs) from high bromide waters (2 mg/L) treated with chlorine or chlorine dioxide used in combination with chlorine and chloramines. This study represents the first comp...

  17. OCCURRENCE AND TOXICITY OF IODO-ACID DISINFECTION BY-PRODUCTS IN CHLORAMINATED DRINKING WATER

    EPA Science Inventory

    As part of a recent Nationwide Disinfection By-Product (DBP) Occurrence Study, iodo-acids were identified for the first time as DBPs in drinking water disinfected with chloramines. The iodo-acids identified included iodoacetic acid (IAA), bromoiodoacetic acid, (E)-3-bromo-3-iodo...

  18. OCCURRENCE OF IODO-ACID AND IODO-THM DISINFECTION BY-PRODUCTS IN DRINKING WATER

    EPA Science Inventory

    As part of a recent Nationwide Disinfection By-product (DBP) Occurrence Study, iodo-acids were identified for the first time as DBPs in drinking water disinfected with chloramines. The iodo-acids identified included iodoacetic acid, bromoiodoacetic acid, (E)-3-bromo-3-iodo- prope...

  19. Biogenic Silver for Disinfection of Water Contaminated with Viruses▿

    PubMed Central

    De Gusseme, Bart; Sintubin, Liesje; Baert, Leen; Thibo, Ellen; Hennebel, Tom; Vermeulen, Griet; Uyttendaele, Mieke; Verstraete, Willy; Boon, Nico

    2010-01-01

    The presence of enteric viruses in drinking water is a potential health risk. Growing interest has arisen in nanometals for water disinfection, in particular the use of silver-based nanotechnology. In this study, Lactobacillus fermentum served as a reducing agent and bacterial carrier matrix for zerovalent silver nanoparticles, referred to as biogenic Ag0. The antiviral action of biogenic Ag0 was examined in water spiked with an Enterobacter aerogenes-infecting bacteriophage (UZ1). Addition of 5.4 mg liter−1 biogenic Ag0 caused a 4.0-log decrease of the phage after 1 h, whereas the use of chemically produced silver nanoparticles (nAg0) showed no inactivation within the same time frame. A control experiment with 5.4 mg liter−1 ionic Ag+ resulted in a similar inactivation after 5 h only. The antiviral properties of biogenic Ag0 were also demonstrated on the murine norovirus 1 (MNV-1), a model organism for human noroviruses. Biogenic Ag0 was applied to an electropositive cartridge filter (NanoCeram) to evaluate its capacity for continuous disinfection. Addition of 31.25 mg biogenic Ag0 m−2 on the filter (135 mg biogenic Ag0 kg−1 filter medium) caused a 3.8-log decline of the virus. In contrast, only a 1.5-log decrease could be obtained with the original filter. This is the first report to demonstrate the antiviral efficacy of extracellular biogenic Ag0 and its promising opportunities for continuous water disinfection. PMID:20038697

  20. Reducing diarrhoea in Guatemalan children: randomized controlled trial of flocculant-disinfectant for drinking-water.

    PubMed Central

    Chiller, Tom M.; Mendoza, Carlos E.; Lopez, M. Beatriz; Alvarez, Maricruz; Hoekstra, Robert M.; Keswick, Bruce H.; Luby, Stephen P.

    2006-01-01

    OBJECTIVE: To examine the effect of a new point-of-use treatment for drinking-water, a commercially developed flocculant-disinfectant, on the prevalence of diarrhoea in children. METHODS: We conducted a randomized controlled trial among 514 rural Guatemalan households, divided into 42 neighbourhood clusters, for 13 weeks, from 4 November 2002 through 31 January 2003. Clusters assigned to water treatment with the flocculant-disinfectant were compared with those using their usual water-handling practices. The longitudinal prevalence of diarrhoea was calculated as the proportion of total days with diarrhoea divided by the total number of days of observation. The prevalence of diarrhoea was compared using the Wilcoxon rank-sum test. FINDINGS: The 1702 people in households receiving the disinfectant had a prevalence of diarrhoea that was 40% lower than that among the 1699 people using standard water-handling practices (0.9% versus 1.5%; P = 0.001). In households using the flocculant-disinfectant, children < 1 year of age had a 39% lower prevalence of diarrhoea than those in households using their standard practices (3.7% versus 6.0%; P = 0.005). CONCLUSION: In settings where families rarely treat drinking-water, we introduced a novel flocculant-disinfectant that reduced the longitudinal prevalence of diarrhoea, especially among children aged < 1 year, among whom diarrhoea has been strongly associated with mortality. Successful introduction and use of this product could contribute to preventing diarrhoeal disease globally. PMID:16501712

  1. Can water disinfection prevent the transmission of infectious koi herpesvirus to naïve carp? - a case report.

    PubMed

    Bergmann, S M; Monro, E S; Kempter, J

    2017-07-01

    Hygienic measures such as disinfection are important tools for the maintenance of fish health in aquaculture. While little information is available on the disinfection of water intended for fish containment, Huwa-San ® , a disinfectant used in food and water industries, was used for daily treatment at concentrations of approximately 60 ppm over a total period of 3 months (experiment 1) with a 3-week treatment-free interval after 2 months (experiment 2). During this period, koi herpesvirus (KHV) was added to the water of two aquaria, one used as a normal contact control, the other one receiving daily water disinfectant treatments that prevented KHV infection of carp. In the second experiment, Huwa-San ® treatment was interrupted and KHV infection was prevalent. However, when naïve fish were introduced to the same aquarium after re-application of disinfectant, KHV could not be detected in those naïve fish. Whilst KHV could not be detected in samples where disinfectant had been applied, it was present in samples of naïve fish cohabiting with infection contact control animals which had undergone no disinfectant treatment over experiments 1 and 2. The results presented here show that water treatment with a disinfectant may prevent transmission of infectious KHV to naïve carp cohabited with infected carp. © 2016 John Wiley & Sons Ltd.

  2. Transformation of pharmaceuticals during oxidation/disinfection processes in drinking water treatment.

    PubMed

    Postigo, Cristina; Richardson, Susan D

    2014-08-30

    Pharmaceuticals are emerging contaminants of concern and are widespread in the environment. While the levels of these substances in finished drinking waters are generally considered too low for human health concern, there are now concerns about their disinfection by-products (DBPs) that can form during drinking water treatment, which in some cases have been proven to be more toxic than the parent compounds. The present manuscript reviews the transformation products of pharmaceuticals generated in water during different disinfection processes, i.e. chlorination, ozonation, chloramination, chlorine dioxide, UV, and UV/hydrogen peroxide, and the main reaction pathways taking place. Most of the findings considered for this review come from controlled laboratory studies involving reactions of pharmaceuticals with these oxidants used in drinking water treatment. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. Silver Ion Biocide Delivery System for Water Disinfection

    NASA Technical Reports Server (NTRS)

    Slote, Benjamin M.; Salley, Edward; Carr, Daniel; Kimble, Michael C.; Adam, Niklas

    2016-01-01

    U.S. space exploration missions have long considered returning to the Moon and exploration of Mars that challenge life support systems. For these long duration missions, there is interest in replacing the iodine water treatment system with ionic silver, a proven biocide. For long duration exploration missions, it is imperative that an effective biocide be used that prevents microbial growth, biofilm formation, and microbially induced corrosion in the water storage and distribution systems while minimizing logistical supply requirements associated with the biocide delivery system. Two biocide delivery systems have been developed that electrochemically produce silver ions for disinfecting water throughout the water storage and distribution system. One system uses a newly developed hybrid micro-filtration and ion-exchange membrane to produce an abundance of silver ions at the 1000 ppb level upstream in the water distribution system to prevent biofilm growth. This is followed by a downstream collection module that electrochemically removes these silver ions before the water is discharged. Another approach uses a membraneless reactor to produce a 1000 ppb silver ion concentration level that also has a mechanically driven electrode cleaning mechanism that removes oxide films ensuring long life operation. By maintaining a sufficiently high level of silver ions throughout the water storage and distribution system, biofilm formation is suppressed. This approach overcomes present concerns where spurious silver deposition occurs on the container and flow line surfaces thus lowering the silver ion concentration to unsatisfactory disinfection levels.

  4. Superabsorbent cryogels decorated with silver nanoparticles as a novel water technology for point-of-use disinfection.

    PubMed

    Loo, Siew-Leng; Fane, Anthony G; Lim, Teik-Thye; Krantz, William B; Liang, Yen-Nan; Liu, Xin; Hu, Xiao

    2013-08-20

    This paper reports the preparation of poly(sodium acrylate) (PSA) cryogels decorated with silver nanoparticles (AgNPs) for point-of-use (POU) water disinfection. The PSA/Ag cryogels combine the high porosity, excellent mechanical and water absorption properties of cryogels, and uniform dispersion of fine AgNPs on the cryogel pore surface for rapid disinfection with minimal Ag release (<100 μg L(-1)). They were used in a process that employed their ability to absorb water, which subsequently could be released via application of mild pressure. Their antibacterial performance was evaluated based on the disinfection efficacies of E. coli and B. subtilis . The PSA/Ag cryogels had excellent disinfection efficacies showing close to a 3 log reduction of viable bacteria after a brief 15 s contact time. They were highly reusable as there was no significant difference in the disinfection efficacies over five cycles of operation. The biocidal action of the PSA/Ag cryogels is believed to be dominated by surface-controlled mechanisms that are dependent on direct contact of the interface of PSA/Ag cryogels with the bacterial cells. The PSA/Ag cryogels are thought to offer a simpler approach for drinking water disinfection in disaster relief applications.

  5. Solar disinfection: an approach for low-cost household water treatment technology in Southwestern Ethiopia.

    PubMed

    Dessie, Awrajaw; Alemayehu, Esayas; Mekonen, Seblework; Legesse, Worku; Kloos, Helmut; Ambelu, Argaw

    2014-01-10

    Disinfection of contaminated water using solar radiation (SODIS) is known to inactivate bacteria. Its inactivation efficiency depends on local conditions where the disinfection is made. This study was aiming to test the efficiency of solar disinfection using different water parameters as low-cost household water treatment technology. Inactivation of microbes was tested using fecal coliform as test organism. The SODIS experiment was carried out at turbidity 2NTU, pH 7, and various water temperature (38.1°C, 41.8°C, 45.6°Cand 51.1°C) and solar intensities, using clear and black plastic bottles filled to different depths. The results show that the rate of microbial inactivation in relation to depth of water, turbidity, container type, intensity of light and color of container was statistically significant (p < 0.05). However, bottle placement, exposure and water pH were unrelated to microbial inactivation. Bacterial re-growth was not observed after solar disinfection. By adjusting the parameters, complete and irreversible fecal coliform inactivation was achieved within an exposure time of less than four hours in the areas where the solar irradiance is about 3.99 kW/m2 and above. Our results indicate that application of SODIS could play a significant role in the provision of safe water in rural communities of developing countries where there is ample sunshine, specifically in sub-Saharan African countries.

  6. Efficacy of Detergent and Water Versus Bleach for the Disinfection of Direct Contact Ophthalmic Lenses

    PubMed Central

    Abbey, Ashkan M.; Gregori, Ninel Z.; Surapaneni, Krishna; Miller, Darlene

    2014-01-01

    Purpose While manufacturers recommend cleaning ophthalmic lenses with detergent and water and then a specific disinfectant, disinfectants are rarely used in ophthalmic practices. The aim of this pilot study was to evaluate the efficacy of detergent and water versus bleach, a recommended disinfectant, to eliminate common ocular bacteria and viruses from ophthalmic lenses. Methods Three bacterial strains (Staphylococcus epidermidis, Corynebacterium straitum, and methicillin-resistant Staphylococcus aureus (MRSA) and two viral strains (adenovirus and herpes simplex virus (HSV) type-1) were individually inoculated to 20 gonioscopy and laser lenses. Lenses were washed with detergent and water and then disinfected with 10% bleach. All lenses were cultured after inoculation, after detergent and water, and after the bleach. Bacterial cultures in thioglycollate broth were observed for 3 weeks and viral cultures for 2 weeks. The presence of viruses was also detected by multiplex polymerase chain reaction (PCR). Results All 20 lenses inoculated with Staphylococcus epidermidis, Corynebacterium straitum, adenovirus, and HSV-1 showed growth after inoculation, but no growth after detergent/water and after the bleach. All lenses showed positive HSV and adenovirus PCR after inoculation and negative PCR after detergent/water and after bleach. All MRSA contaminated lenses showed growth after inoculation and no growth after detergent and water. However, one lens showed positive growth after bleach. Conclusions Cleaning with detergent and water appeared to effectively eliminate bacteria and viruses from the surface of contaminated ophthalmic lenses. Further studies are warranted to design practical disinfection protocols that minimize lens damage. PMID:24747806

  7. Formation of nitrogenous disinfection by-products in 10 chlorinated and chloraminated drinking water supply systems.

    PubMed

    Liew, Deborah; Linge, Kathryn L; Joll, Cynthia A

    2016-09-01

    The presence of nitrogenous disinfection by-products (N-DBPs) in drinking water supplies is a public health concern, particularly since some N-DBPs have been reported to be more toxic than the regulated trihalomethanes and haloacetic acids. In this paper, a comprehensive evaluation of the presence of N-DBPs in 10 drinking water supply systems in Western Australia is presented. A suite of 28 N-DBPs, including N-nitrosamines, haloacetonitriles (HANs), haloacetamides (HAAms) and halonitromethanes (HNMs), were measured and evaluated for relationships with bulk parameters in the waters before disinfection. A number of N-DBPs were frequently detected in disinfected waters, although at generally low concentrations (<10 ng/L for N-nitrosamines and <10 μg/L for other N-DBPs) and below health guideline values where they exist. While there were no clear relationships between N-DBP formation and organic nitrogen in the pre-disinfection water, N-DBP concentrations were significantly correlated with dissolved organic carbon (DOC) and ammonia, and these, in addition to high bromide in one of the waters, led to elevated concentrations of brominated HANs (26.6 μg/L of dibromoacetonitrile). There were significant differences in the occurrence of all classes of N-DBPs between chlorinated and chloraminated waters, except for HNMs, which were detected at relatively low concentrations in both water types. Trends observed in one large distribution system suggest that N-DBPs can continue to form or degrade within distribution systems, and redosing of disinfectant may cause further by-product formation.

  8. IDENTIFICATION OF NEW DISINFECTION BY-PRODUCTS IN DRINKING WATER

    EPA Science Inventory

    Due to concern over the potential adverse health effects of trihalomethanes (THMs) and other chlorinated by-products in chlorinated drinking water, alternative disinfectants are being explored. Ozone, chlorine dioxide, and chloramine are popular alternatives, as they produce low...

  9. Drinking water disinfection byproducts: review and approach to toxicity evaluation.

    PubMed

    Boorman, G A

    1999-02-01

    There is widespread potential for human exposure to disinfection byproducts (DBPs) in drinking water because everyone drinks, bathes, cooks, and cleans with water. The need for clean and safe water led the U.S. Congress to pass the Safe Drinking Water Act more than 20 years ago in 1974. In 1976, chloroform, a trihalomethane (THM) and a principal DBP, was shown to be carcinogenic in rodents. This prompted the U.S. Environmental Protection Agency (U.S. EPA) in 1979 to develop a drinking water rule that would provide guidance on the levels of THMs allowed in drinking water. Further concern was raised by epidemiology studies suggesting a weak association between the consumption of chlorinated drinking water and the occurrence of bladder, colon, and rectal cancer. In 1992 the U.S. EPA initiated a negotiated rulemaking to evaluate the need for additional controls for microbial pathogens and DBPs. The goal was to develop an approach that would reduce the level of exposure from disinfectants and DBPs without undermining the control of microbial pathogens. The product of these deliberations was a proposed stage 1 DBP rule. It was agreed that additional information was necessary on how to optimize the use of disinfectants while maintaining control of pathogens before further controls to reduce exposure beyond stage 1 were warranted. In response to this need, the U.S. EPA developed a 5-year research plan to support the development of the longer term rules to control microbial pathogens and DBPs. A considerable body of toxicologic data has been developed on DBPs that occur in the drinking water, but the main emphasis has been on THMs. Given the complexity of the problem and the need for additional data to support the drinking water DBP rules, the U.S. EPA, the National Institute of Environmental Health Sciences, and the U.S. Army are working together to develop a comprehensive biologic and mechanistic DBP database. Selected DBPs will be tested using 2-year toxicity and

  10. Effect of Disinfectant Exposure on Legionella pneumophila Associated with Simulated Drinking Water Biofilms: Release, Inactivation, and Infectivity.

    PubMed

    Shen, Yun; Huang, Conghui; Lin, Jie; Wu, Wenjing; Ashbolt, Nicholas J; Liu, Wen-Tso; Nguyen, Thanh H

    2017-02-21

    Legionella pneumophila, the most commonly identified causative agent in drinking water associated with disease outbreaks, can be harbored by and released from drinking water biofilms. In this study, the release of biofilm-associated L. pneumophila under simulated drinking water flow containing a disinfectant residual was examined. Meanwhile, the inactivation and infectivity (to amoebae) of the released L. pneumophila were studied. To simulate drinking water system conditions, biofilms were prepared under either disinfectant exposure (predisinfected biofilms) or disinfectant-free (untreated biofilms) conditions, respectively. For experiments with water flow containing a disinfectant to release the biofilm-associated L. pneumophila from these two types of biofilms, the L. pneumophila release kinetics values from predisinfected and untreated biofilms under flow condition were not statistically different (one-way ANOVA, p > 0.05). However, inactivation of the L. pneumophila released from predisinfected biofilms was 1-2 times higher and amoeba infectivity was 2-29 times lower than that from untreated biofilms. The higher disinfectant resistance of L. pneumophila released from untreated biofilms was presumably influenced by the detachment of a larger amount of biofilm material (determined by 16S rRNA qPCR) surrounding the released L. pneumophila. This study highlights the interaction among disinfectant residual, biofilms, and L. pneumophila, which provides guidelines to assess and control pathogen risk.

  11. Prevention of Cross-contamination Risk by Disinfection of Irreversible Hydrocolloid Impression Materials with Ozonated Water.

    PubMed

    Savabi, Omid; Nejatidanesh, Farahnaz; Bagheri, Kamran Poshang; Karimi, Leila; Savabi, Ghazal

    2018-01-01

    Disinfection of dental impression is mandatory for preventing the cross infection between dental staff and dental laboratory. Ozone as a disinfectant can be used in various ways in dentistry. The aim of this study was to evaluate the efficacy of ozonated water for disinfection of irreversible hydrocolloid impression materials and preventing cross-contamination. Thirty-two circular specimens (1 cm diameter and 2 mm thickness) of irreversible hydrocolloid impression material were made. Thirty specimens were contaminated with Pseudomonas aeruginosa (ATCC 27853), Staphylococcus aureus (ATCC 51299), and Candida albicans (PTCC 5027). Except control samples ( n = 2), the other specimens were immersed in ozonated water for 5 and 10 min (5 sample each group). Trypsin was used for separating microorganisms. Diluted microbial solution was analyzed microbiologically for colony-forming units (CFUs). Two-way repeated measure ANOVA and Scheffe post hoc test were used for data analysis (α = 0.05). The number of CFUs after disinfection with ozonated water was decreased significantly (11.84%, 61.55%, and 20.27% after 5 min and 11.03%, 14.50%, and 16.99% after 10 min for P. aeruginosa , S. aureus , and C. albicans , respectively) ( P < 0.001). Increasing the time of disinfection resulted in significant reduction in a number of S. aureus only ( P < 0.001) although they did not vanish microorganisms completely. Immersion of irreversible hydrocolloid impression material in ozonated water for 10 min will not lead to complete disinfection but decreases the microorganisms to a level that can prevent infection transmission.

  12. Efficacy of Various Chemical Disinfectants on Biofilms Formed in Spacecraft Potable Water System Component

    NASA Technical Reports Server (NTRS)

    Wong, Willy; Garcia, Veronica; Castro, Victoria; Ott, Mark; Duane

    2009-01-01

    As the provision of potable water is critical for successful habitation of the International Space Station (ISS), life support systems were installed in December 2008 to recycle both humidity from the atmosphere and urine to conserve available water in the vehicle. Pre-consumption testing from the dispensing needle at the Potable Water Dispenser (PWD) indicated that bacterial concentrations exceeded the current ISS specifications of 50 colony forming units (CFU) per ml. Subsequent investigations revealed that a corrugated stainless steel flex hose upstream of the dispensing needle in the PWD was filled with non-sterile water and left at room temperature for over one month before launch. To simulate biofilm formation that was suspected in the flight system, sterile flex hoses were seeded with a consortium of bacterial isolates previously recovered from other ISS water systems, which included Ralstonia pickettii, Burkholderia multivorans, Caulobacter vibrioides., and Cupriavidus pauculus. After 5 days of incubation, these hoses were challenged with various chemical disinfectants including hydrogen peroxide, colloidal silver, and buffered pH solutions to determine the ability of the disinfectants to decrease and maintain bacterial concentrations below ISS specifications. Disinfection efficacy over time was measured by collecting daily heterotrophic plate counts following exposure to the disinfectants. A single flush with either 6% hydrogen peroxide solution or a mixture of 3% hydrogen peroxide and 400 ppb colloidal silver effectively reduced the bacterial concentrations to less than 1 CFU/ml for a period of up to 2 months. Testing results indicated that hydrogen peroxide and mixtures of hydrogen peroxide and colloidal silver have tremendous potential as alternative disinfectants for ISS water systems.

  13. Spectral irradiance measurement and actinic radiometer calibration for UV water disinfection

    NASA Astrophysics Data System (ADS)

    Sperfeld, Peter; Barton, Bettina; Pape, Sven; Towara, Anna-Lena; Eggers, Jutta; Hopfenmüller, Gabriel

    2014-12-01

    In a joint project, sglux and PTB investigated and developed methods and equipment to measure the spectral and weighted irradiance of high-efficiency UV-C emitters used in water disinfection plants. A calibration facility was set up to calibrate the microbicidal irradiance responsivity of actinic radiometers with respect to the weighted spectral irradiance of specially selected low-pressure mercury and medium-pressure mercury UV lamps. To verify the calibration method and to perform on-site tests, spectral measurements were carried out directly at water disinfection plants in operation. The weighted microbicidal irradiance of the plants was calculated and compared to the measurements of various actinic radiometers.

  14. New formaldehyde base disinfectants.

    NASA Technical Reports Server (NTRS)

    Trujillo, R.; Lindell, K. F.

    1973-01-01

    Preparations of formaldehyde in various organic liquids - ethylene glycol, glycerol, and propylene glycol - serve as effective disinfectants towards microbial vegetative cells and spores. This disinfection is a temperature-dependent process and is manifest when these formaldehyde base disinfectants are dissolved in water. The irritating vapors associated with formaldehyde disinfection are not present in either of these new formaldehyde base disinfectants or in aqueous solutions of them.

  15. ANALYTICAL METHODS FOR WATER DISINFECTION BY-PRODUCTS IN FOODS AND BEVERAGES

    EPA Science Inventory

    The determination of exposure to drinking water disinfection byproducts (DBPs) requires an understanding of how drinking water comes in contact with humans through multiple pathways. In order to facilitate the investigation of human exposure to DBPs via foods and beverages, analy...

  16. Comparative Evaluation of Alternative Disinfectants for Drinking Water and Wastewater Treatment

    EPA Science Inventory

    The Water Supply and Water Resources Division (WSWRD) of the U.S. Environmental Protection Agency’s (EPA) National Risk Management Research Laboratory (NRMRL) initiated a research program to evaluate the performance of various disinfectants that could potentially be used in drink...

  17. Solar disinfection: an approach for low-cost household water treatment technology in Southwestern Ethiopia

    PubMed Central

    2014-01-01

    Disinfection of contaminated water using solar radiation (SODIS) is known to inactivate bacteria. Its inactivation efficiency depends on local conditions where the disinfection is made. This study was aiming to test the efficiency of solar disinfection using different water parameters as low-cost household water treatment technology. Inactivation of microbes was tested using fecal coliform as test organism. The SODIS experiment was carried out at turbidity 2NTU, pH 7, and various water temperature (38.1°C, 41.8°C, 45.6°Cand 51.1°C) and solar intensities, using clear and black plastic bottles filled to different depths. The results show that the rate of microbial inactivation in relation to depth of water, turbidity, container type, intensity of light and color of container was statistically significant (p < 0.05). However, bottle placement, exposure and water pH were unrelated to microbial inactivation. Bacterial re-growth was not observed after solar disinfection. By adjusting the parameters, complete and irreversible fecal coliform inactivation was achieved within an exposure time of less than four hours in the areas where the solar irradiance is about 3.99 kW/m2 and above. Our results indicate that application of SODIS could play a significant role in the provision of safe water in rural communities of developing countries where there is ample sunshine, specifically in sub-Saharan African countries. PMID:24410979

  18. The effect of chlorine and combined chlorine/UV treatment on coliphages in drinking water disinfection.

    PubMed

    Zyara, Alyaa M; Torvinen, Eila; Veijalainen, Anna-Maria; Heinonen-Tanski, Helvi

    2016-08-01

    Chlorine disinfection is a globally used method to ensure the safety of drinking water. However, it has not always been successful against viruses and, therefore, it is important to find new methods to disinfect water. Seventeen different coliphages were isolated from the treated municipal wastewater. These coliphages and MS2 were treated with different dosages of chlorine in drinking water, and a combined chlorine/ultraviolet irradiation treatment for the chlorine-resistant coliphages. Chlorine disinfection with 0.3-0.5 mg/L total chlorine (free Cl-dosage 0.12-0.21 mg/L) for 10 min achieved 2.5-5.7 Log10-reductions for 11 sensitive coliphages. The six most resistant coliphages showed no reduction with these chlorine concentrations. MS2 was intermediate in chlorine resistance, and thus it is not a good indicator for viruses in chlorine disinfection. In the combined treatment total chlorine of 0.05-0.25 mg/L (free Cl-dosage 0.02-0.08 mg/L) and ultraviolet irradiation (14-22 mWs/cm(2)) were more effective than chlorine alone, and 3-5 Log10-reductions were achieved for the chlorine-resistant strains. The chlorination efficiency could be increased by higher dosages and longer contact times, but this could increase the formation of disinfection by-products. Therefore, the combination treatment is a recommended disinfection method.

  19. OCCURRENCE OF IODO-ACID AND IODO-THM DISINFECTION BY-PRODUCTS IN CHLORAMINATED DRINKING WATER

    EPA Science Inventory

    As part of a recent Nationwide Disinfection By-Product (DBP) Occurrence Study, iodo-acids were identified for the first time as DBPs in drinking water disinfected with chloramines. The iodo-acids identified included iodoacetic acid, bromoiodoacetic acid, (E)-3-bromo-3-iodo-prope...

  20. Cryptosporidium-contaminated water disinfection by a novel Fenton process.

    PubMed

    Matavos-Aramyan, Sina; Moussavi, Mohsen; Matavos-Aramyan, Hedieh; Roozkhosh, Sara

    2017-05-01

    Three novel modified advanced oxidation process systems including ascorbic acid-, pro-oxidants- and ascorbic acid-pro-oxidants-modified Fenton system were utilized to study the disinfection efficiency on Cryptosporidium-contaminated drinking water samples. Different concentrations of divalent and trivalent iron ions, hydrogen peroxide, ascorbic acid and pro-oxidants at different exposure times were investigated. These novel systems were also compared to the classic Fenton system and to the control system which comprised of only hydrogen peroxide. The complete in vitro mechanism of the mentioned modified Fenton systems are also provided. The results pointed out that by considering the optimal parameter limitations, the ascorbic acid-modified Fenton system decreased the Cryptosporidium oocytes viability to 3.91%, while the pro-oxidant-modified and ascorbic acid-pro-oxidant-modified Fenton system achieved an oocytes viability equal to 1.66% and 0%, respectively. The efficiency of the classic Fenton at optimal condition was observed to be 20.12% of oocytes viability. The control system achieved 86.14% of oocytes viability. The optimum values of the operational parameters during this study are found to be 80mgL -1 for the divalent iron, 30mgL -1 for ascorbic acid, 30mmol for hydrogen peroxide, 25mgL -1 for pro-oxidants and an exposure time equal to 5min. The ascorbic acid-pro-oxidants-modified Fenton system achieved a promising complete water disinfection (0% viability) at the optimal conditions, leaving this method a feasible process for water disinfection or decontamination, even at industrial scales. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. The impact of iodinated X-ray contrast agents on formation and toxicity of disinfection by-products in drinking water.

    PubMed

    Jeong, Clara H; Machek, Edward J; Shakeri, Morteza; Duirk, Stephen E; Ternes, Thomas A; Richardson, Susan D; Wagner, Elizabeth D; Plewa, Michael J

    2017-08-01

    The presence of iodinated X-ray contrast media (ICM) in source waters is of high concern to public health because of their potential to generate highly toxic disinfection by-products (DBPs). The objective of this study was to determine the impact of ICM in source waters and the type of disinfectant on the overall toxicity of DBP mixtures and to determine which ICM and reaction conditions give rise to toxic by-products. Source waters collected from Akron, OH were treated with five different ICMs, including iopamidol, iopromide, iohexol, diatrizoate and iomeprol, with or without chlorine or chloramine disinfection. The reaction product mixtures were concentrated with XAD resins and the mammalian cell cytotoxicity and genotoxicity of the reaction mixture concentrates was measured. Water containing iopamidol generated an enhanced level of mammalian cell cytotoxicity and genotoxicity after disinfection. While chlorine disinfection with iopamidol resulted in the highest cytotoxicity overall, the relative iopamidol-mediated increase in toxicity was greater when chloramine was used as the disinfectant compared with chlorine. Four other ICMs (iopromide, iohexol, diatrizoate, and iomeprol) expressed some cytotoxicity over the control without any disinfection, and induced higher cytotoxicity when chlorinated. Only iohexol enhanced genotoxicity compared to the chlorinated source water. Copyright © 2017. Published by Elsevier B.V.

  2. DISINFECTION BYPRODUCTS IN DRINKING WATER [LETTER TO THE EDITOR

    EPA Science Inventory

    Comment on Professor Howard Weinberg's report on the analysis of potable water for disinfection byproducts.

    "I am unconvinced that it is necessary to identify and quantify each individual compound. Suppose we identify 1000 or 10,000 individual compounds, can we afford t...

  3. Sequential UV- and chlorine-based disinfection to mitigate Escherichia coli in drinking water biofilms.

    PubMed

    Murphy, H M; Payne, S J; Gagnon, G A

    2008-04-01

    This study was designed to examine the potential downstream benefits of sequential disinfection to control the persistence of Escherichia coli under conditions relevant to drinking water distribution systems. Eight annular reactors (four polycarbonate and four cast iron) were setup in parallel to address various factors that could influence biofilm growth in distribution systems. Eight reactors were treated with chlorine, chlorine dioxide and monochloramine alone or in combination with UV to examine the effects on Escherichia coli growth and persistence in both the effluent and biofilm. In general, UV-treated systems in combination with chlorine or chlorine dioxide and monochloramine achieved greater log reductions in both effluent and biofilm than systems treated with chlorine-based disinfectants alone. However, during UV-low chlorine disinfection, E. coli was found to persist at low levels, suggesting that the UV treatment had instigated an adaptive mutation. During UV-chlorine-dioxide treatment, the E. coli that was initially below the detection limit reappeared during a low level of disinfection (0.2 mg/L) in the cast iron systems. Chloramine was shown to be effective in disinfecting suspended E. coli in the effluent but was unable to reduce biofilm counts to below the detection limit. Issues such as repair mechanism of E. coli and nitrification could help explain some of these aberrations. Improved understanding of the ability of chlorine-based disinfectant in combination with UV to provide sufficient disinfection will ultimately effect in improved management and safety of drinking water.

  4. Seasonal evaluation of disinfection by-products throughout two full-scale drinking water treatment plants.

    PubMed

    Zhong, Xin; Cui, Chongwei; Yu, Shuili

    2017-07-01

    Carbonyl compounds can occur alpha-hydrogens or beta-diketones substitution reactions with disinfectants contributed to halogenated by-products formation. The objective of this research was to study the occurrence and fate of carbonyl compounds as ozonation by-products at two full-scale drinking water treatment plants (DWTPs) using different disinfectants for one year. The quality of the raw water used in both plants was varied according to the season. The higher carbonyl compounds concentrations were found in raw water in spring. Up to 15 (as the sum of both DWTPs) of the 24 carbonyl compounds selected for this work were found after disinfection. The dominant carbonyl compounds were formaldehyde, glyoxal, methyl-glyoxal, fumaric, benzoic, protocatechuic and 3-hydroxybenzoic acid at both DWTPs. In the following steps in each treatment plant, the concentration patterns of these carbonyl compounds differed depending on the type of disinfectant applied. Benzaldehyde was the only aromatic aldehyde detected after oxidation with ozone in spring. As compared with DWTP 1, five new carbonyl compounds were formed (crotonaldehyde, benzaldehyde, formic, oxalic and malonic acid) disinfection by ozone, and the levels of the carbonyl compounds increased. In addition, pre-ozonation (PO) and main ozonation (OZ) increased the levels of carbonyl compounds, however coagulation/flocculation (CF), sand filtration (SF) and granular activated carbon filtration (GAC) decreased the levels of carbonyl compounds. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Evaluation of an Innovative Approach to Validation of Ultraviolet (UV) Reactors for Disinfection in Drinking Water Systems

    EPA Science Inventory

    UV disinfection is an effective process for inactivating many microbial pathogens found in source waters with the potential as stand-alone treatment or in combination with other disinfectants. For surface and groundwater sourced drinking water applications, the U.S. Environmental...

  6. MASS SPECTROMETRY OF DRINKING WATER CONTAMINANTS: DISINFECTION BY-PRODUCTS AND THE US EPA CONTAMINANT CANDIDATE LIST COMPOUNDS

    EPA Science Inventory

    Disinfection by-products (DBPs) are the thousands of compounds created during the disinfection of drinking water. These compounds can create potential health risks, challenge drinking water treatment technology, and pose difficulties in their analysis. Research in the use of ga...

  7. Impact of chlorinated disinfection on copper corrosion in hot water systems

    NASA Astrophysics Data System (ADS)

    Montes, J. Castillo; Hamdani, F.; Creus, J.; Touzain, S.; Correc, O.

    2014-09-01

    In France, hot water quality control inside buildings is occasionally ensured by disinfection treatments using temperature increases or addition of sodium hypochlorite (between 0.5 ppm and 1 ppm residual free chlorine). This disinfectant is a strong oxidiser and it could interact with metallic pipes usually used in hot water systems. This work deals with the study of the impact of these treatments on the durability of copper pipes. The objective of this work was to investigate the influence of sodium hypochlorite concentration and temperature on the copper corrosion mechanism. Copper samples were tested under dynamic and static conditions of ageing with sodium hypochlorite solutions ranging from 0 to 100 ppm with temperature at 50 °C and 70 °C. The efficiency of a corrosion inhibitor was investigated in dynamic conditions. Visual observations and analytical analyses of the internal surface of samples was studied at different ageing duration. Corrosion products were characterised by X-ray diffraction and Raman spectroscopy. Temperature and disinfectant were found to considerably affect the copper corrosion mechanism. Surprisingly, the corrosiveness of the solution was higher at lower temperatures. The temperature influences the nature of corrosion products. The protection efficiency is then strongly depend on the nature of the corrosion products formed at the surface of copper samples exposed to the aggressive solutions containing different concentration of disinfectant.

  8. Relationship of drinking water disinfectants to plasma cholesterol and thyroid hormone levels in experimental studies.

    PubMed Central

    Revis, N W; McCauley, P; Bull, R; Holdsworth, G

    1986-01-01

    The effects of drinking water containing 2 or 15 ppm chlorine (pH 6.5 and 8.5), chlorine dioxide, and monochloramine on thyroid function and plasma cholesterol were studied because previous investigators have reported cardiovascular abnormalities in experimental animals exposed to chlorinated water. Plasma thyroxine (T4) levels, as compared to controls, were significantly decreased in pigeons fed a normal or high-cholesterol diet and drinking water containing these drinking water disinfectants at a concentration of 15 ppm (the exception was chlorine at pH 6.5) for 3 months. In most of the treatment groups, T4 levels were significantly lower following the exposure to drinking water containing the 2 ppm dose. Increases in plasma cholesterol were frequently observed in the groups with lower T4 levels. This association was most evident in pigeons fed the high-cholesterol diet and exposed to these disinfectants at a dose of 15 ppm. For example, after 3 months of exposure to deionized water or water containing 15 ppm monochloramine, plasma cholesterol was 1266 +/- 172 and 2049 +/- 212 mg/dl, respectively, a difference of 783 mg/dl. The factor(s) associated with the effect of these disinfectants on plasma T4 and cholesterol is not known. We suggest however that these effects are probably mediated by products formed when these disinfectants react with organic matter in the upper gastrointestinal tract. PMID:3456597

  9. Mass Spectrometry Identification of Toxicologically Important Drinking Water Disinfection By-Products

    EPA Science Inventory

    The disinfection of drinking water has been rightly hailed as a public health triumph of the 20th century. Before its widespread use, millions of people died from waterborne diseases. Now, people in developed nations receive quality drinking water every day from their public wate...

  10. Integrated Disinfection By-Products Mixtures Research: Concentration by Reverse Osmosis Membrane Techniques of Disinfection By-Products from Water Disinfected by Chlorination and Ozonation/Postchlorination

    EPA Science Inventory

    To conduct the health-effect studies described in subsequent articles in this series, concentrated aqueous mixtures of disinfection by-products were required for the two water treatment trains described in the preceding article (Miltner et al., 2008). To accomplish this, the fini...

  11. Comparison of Point-of-Use Technologies for Emergency Disinfection of Sewage-Contaminated Drinking Water

    PubMed Central

    McLennan, S. Devin; Peterson, Lauren A.; Rose, Joan B.

    2009-01-01

    Four point-of-use disinfection technologies for treating sewage-contaminated well water were compared. Three systems, based on flocculant-disinfectant packets and N-halamine chlorine and bromine contact disinfectants, provided a range of 4.0 to >6.6 log10 reductions (LR) of naturally occurring fecal indicator and heterotrophic bacteria and a range of 0.9 to >1.9 LR of coliphage. PMID:19767479

  12. ORD'S FOUR LAB STUDY: TOXICOLOGICAL AND CHEMICAL EVALUATION OF COMPLEX MIXTURES OF DRINKING WATER DISINFECTION BY-PRODUCTS

    EPA Science Inventory

    Disinfectants used in the production of drinking water react with naturally occurring organic and inorganic material in the source water to produce disinfection by-products (DBPs). Humans are exposed daily to a complex mixture of DBPs via oral, dermal, and inhalation routes. To ...

  13. CONTROL OF MICROBIAL CONTAMINANTS AND DISINFECTION BY-PRODUCTS IN DRINKING WATER: COST AND PERFORMANCE

    EPA Science Inventory

    The U.S. Environmental Protection Agency (U.S. EPA) is in the process of developing a sophisticated regulatory strategy in an attempt to balance the risks associated with disinfectants and disinfection by-products (D/DBP) in drinking water. A major aspect of this strategy is the...

  14. Silver nanoparticle-alginate composite beads for point-of-use drinking water disinfection.

    PubMed

    Lin, Shihong; Huang, Rixiang; Cheng, Yingwen; Liu, Jie; Lau, Boris L T; Wiesner, Mark R

    2013-08-01

    Silver nanoparticles (AgNPs)-alginate composite beads were synthesized using three different approaches as filler materials of packed columns for simultaneous filtration-disinfection as an alternative portable water treatment process. The prepared composite beads were packed into a column through which Escherichia coli containing water was filtered to evaluate the disinfection efficacy. Excellent disinfection performance (no detectable viable colony) was achieved with a hydraulic retention time (HRT) as short as 1 min (the shortest tested) with the SGR (Simultaneous-Gelation-Reduction) and AR (Adsorption-Reduction) beads that were prepared using in situ reduction of Ag(+). Comparatively, the SGR beads released significantly less Ag(+)/AgNPs than the AR beads did within the same HRT. From the results of this study it was identified that SGR may be the best choice among all three different synthesis approaches in that the SGR beads can achieve satisfactory bactericidal performance with a relatively low material consumption rate. Copyright © 2012 Elsevier Ltd. All rights reserved.

  15. Removal of bacteria, protozoa and viruses through a multiple-barrier household water disinfection system.

    PubMed

    Espinosa-García, A C; Díaz-Ávalos, C; Solano-Ortiz, R; Tapia-Palacios, M A; Vázquez-Salvador, N; Espinosa-García, S; Sarmiento-Silva, R E; Mazari-Hiriart, M

    2014-03-01

    Municipal water disinfection systems in some areas are not always able to meet water consumer needs, such as ensuring distributed water quality, because household water management can be a contributing factor in water re-contamination. This fact is related to the storage options that are common in places where water is scarce or is distributed over limited time periods. The aim of this study is to assess the removal capacity of a multiple-barrier water disinfection device for protozoa, bacteria, and viruses. Water samples were taken from households in Mexico City and spiked with a known amount of protozoa (Giardia cyst, Cryptosporidium oocyst), bacteria (Escherichia coli), and viruses (rotavirus, adenovirus, F-specific ribonucleic acid (FRNA) coliphage). Each inoculated sample was processed through a multiple-barrier device. The efficiency of the multiple-barrier device to remove E. coli was close to 100%, and more than 87% of Cryptosporidium oocysts and more than 98% of Giardia cysts were removed. Close to 100% of coliphages were removed, 99.6% of the adenovirus was removed, and the rotavirus was almost totally removed. An effect of site by zone was detected; this observation is important because the water characteristics could indicate the efficiency of the multiple-barrier disinfection device.

  16. Methodology for modeling the disinfection efficiency of fresh-cut leafy vegetables wash water applied on peracetic acid combined with lactic acid.

    PubMed

    Van Haute, S; López-Gálvez, F; Gómez-López, V M; Eriksson, Markus; Devlieghere, F; Allende, Ana; Sampers, I

    2015-09-02

    A methodology to i) assess the feasibility of water disinfection in fresh-cut leafy greens wash water and ii) to compare the disinfectant efficiency of water disinfectants was defined and applied for a combination of peracetic acid (PAA) and lactic acid (LA) and comparison with free chlorine was made. Standardized process water, a watery suspension of iceberg lettuce, was used for the experiments. First, the combination of PAA+LA was evaluated for water recycling. In this case disinfectant was added to standardized process water inoculated with Escherichia coli (E. coli) O157 (6logCFU/mL). Regression models were constructed based on the batch inactivation data and validated in industrial process water obtained from fresh-cut leafy green processing plants. The UV254(F) was the best indicator for PAA decay and as such for the E. coli O157 inactivation with PAA+LA. The disinfection efficiency of PAA+LA increased with decreasing pH. Furthermore, PAA+LA efficacy was assessed as a process water disinfectant to be used within the washing tank, using a dynamic washing process with continuous influx of E. coli O157 and organic matter in the washing tank. The process water contamination in the dynamic process was adequately estimated by the developed model that assumed that knowledge of the disinfectant residual was sufficient to estimate the microbial contamination, regardless the physicochemical load. Based on the obtained results, PAA+LA seems to be better suited than chlorine for disinfecting process wash water with a high organic load but a higher disinfectant residual is necessary due to the slower E. coli O157 inactivation kinetics when compared to chlorine. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Use of solar radiation for continuous water disinfection in isolated areas.

    PubMed

    Fabbricino, M; d'Antonio, L

    2012-01-01

    This study involved investigation of solar water disinfection in continuously working treatment plants with the aim of producing safe drinking water in isolated areas. Results were obtained from experimental work carried out on a pilot plant operating in different configurations. The use of a simple device to increase solar radiation intensity (solar concentrator) was tested, with results showing that it facilitated better performance. A comparison between transparent and black-painted glass reactors was also made, showing no difference between the two casings. Further, the effect of an increase in water temperature was analysed in detail. Temperature was found to play an important role in the disinfection process, even in cases of limited solar radiation intensities, although a synergistic effect of water heating and solar radiation for effective microbial inactivation was confirmed. Reactor design is also discussed, highlighting the importance of having a plug flow to avoid zones that do not contribute to the overall effectiveness of the process.

  18. IDENTIFICATION OF TI02/UV DISINFECTION BYPRODUCTS IN DRINKING WATER

    EPA Science Inventory

    Due to concern over the presence of trihalomethanes (THMs) and other chlorinated byproducts in chlorinated drinking water, alternative disinfection methods are being explored. One of the alternative treatment methods currently being evaluated for potential use with small systems ...

  19. Limnoithona sinensis as refuge for bacteria: protection from UV radiation and chlorine disinfection in drinking water treatment.

    PubMed

    Lin, Tao; Cai, Bo; Chen, Wei

    2014-11-01

    In this study, we tested the potential of Limnoithona sinensis to provide its attached bacteria refuge against disinfection. The experimental results indicated that in water devoid of zooplankton, both UV radiation and chlorine disinfection significantly decreased the viability of free-living bacteria. In the presence of L. sinensis, however, the attached bacteria could survive and rapidly recover from disinfection. This demonstrated that L. sinensis provided protection from external damage to various aquatic bacteria that were attached to its body. The surviving bacteria remained on L. sinensis after disinfection exposure, which enabled a rapid increase in the bacterial population followed by their subsequent release into the surrounding water. Compared with UV radiation, chlorine disinfection was more effective in terms of inactivating attached bacteria. Both UV radiation and chlorine disinfection had little effect in terms of preventing the spread of undesirable bacteria, due to the incomplete inactivation of the bacteria associated with L. sinensis.

  20. Chlorine disinfection of recreational water for Cryptosporidium parvum.

    PubMed Central

    Carpenter, C.; Fayer, R.; Trout, J.; Beach, M. J.

    1999-01-01

    We examined the effects of chlorine on oocyst viability, under the conditions of controlled pH and elevated calcium concentrations required for most community swimming pools. We found that fecal material may alter the Ct values (chlorine concentration in mg/L, multiplied by time in minutes) needed to disinfect swimming pools or other recreational water for Cryptosporidium parvum. PMID:10458969

  1. Mammalian Cell Cytotoxicity and Genotoxicity of the Haloacetic Acids, A Major Class of Drinking Water Disinfection By-Products

    EPA Science Inventory

    The haloacetic acids (HAAs) are disinfection by-products (DBPs) that are formed during the disinfection of drinking water, wastewaters and recreational pool waters. Currently, five HAAs [bromoacetic acid (BAA), dibromoacetic acid (DBAA), chloroacetic acid (CAA), dichloroacetic ac...

  2. Evaluation of bactericidal efficacy of silver ions on Escherichia coli for drinking water disinfection.

    PubMed

    Pathak, Satya P; Gopal, K

    2012-07-01

    The purpose of this study is the development of a suitable process for the disinfection of drinking water by evaluating bactericidal efficacy of silver ions from silver electrodes. A prototype of a silver ioniser with silver electrodes and control unit has been fabricated. Silver ions from silver electrodes in water samples were estimated with an atomic absorption spectrophotometer. A fresh culture of Escherichia coli (1.75 × 10(3) c.f.u./ml) was exposed to 1, 2, 5, 10 and 20 ppb of silver ions in 100 ml of autoclaved tap water for 60 min. The effect of different pH and temperatures on bactericidal efficacy was observed at constant silver ion concentration (5 ppb) and contact time of 30 min. The maximum bactericidal activity (100%) was observed at 20 ppb of silver ion concentration indicating total disinfection after 20 min while minimum bactericidal activity (25%) was observed after 10 min at 01 ppb of silver ions. Likewise, 100% bactericidal activity was noticed with 2, 5 and 10 ppb of silver ions after 60, 50 and 40 min, respectively. Bactericidal activity at pH 5, 6, 7, 8 and 9 was observed at 79.9%, 79.8%, 80.5%, 100% and 100%, respectively, whereas it was 80.4%, 88.3%, 100%, 100% and 100% at 10°C, 20°C, 30°C, 40°C and 50°C, respectively. The findings of this study revealed that very low concentrations of silver ions at pH 8-9 and temperature >20°C have bactericidal efficacy for total disinfection of drinking water. Silver ionisation is suitable for water disinfection and an appropriate alternative to chlorination which forms carcinogenic disinfection by-products.

  3. Evaluation of thirteen haloacetic acids and ten trihalomethanes formation by peracetic acid and chlorine drinking water disinfection.

    PubMed

    Xue, Runmiao; Shi, Honglan; Ma, Yinfa; Yang, John; Hua, Bin; Inniss, Enos C; Adams, Craig D; Eichholz, Todd

    2017-12-01

    Free chlorine is a commonly used disinfectant in drinking water treatment. However, disinfection by-products (DBPs) are formed during water disinfection. Haloacetic acids (HAAs) and trihalomethanes (THMs) are two major groups of DBPs. Iodo-HAAs and iodo-THMs (I-HAAs and I-THMs) are formed during the disinfection of the water containing high levels of iodide and are much more toxic than their chlorinated and brominated analogs. Peracetic acid (PAA) is a strong antimicrobial disinfectant that is expected to reduce the formation of HAAs and THMs during disinfection. In this study, the formations of thirteen HAAs and ten THMs, including the iodinated forms, have been investigated during PAA disinfection and chlorination as the comparison. The DBP formations under different iodide concentrations, pHs, and contact times were systematically investigated. Two types of commercial PAAs containing different concentrations of PAA and hydrogen peroxide (H 2 O 2 ) were studied. A solid-phase microextraction gas chromatography-mass spectrometry method was upgraded for THM analysis including I-THMs. HAAs were analyzed by following a recently developed high performance ion chromatography-tandem mass spectrometry method. Results show that the ratio of PAA and H 2 O 2 concentration significantly affect the formation of I-THMs and I-HAAs. During PAA disinfection with lower PAA than H 2 O 2 , no detectable levels of THMs and HAAs were observed. During PAA disinfection with higher PAA than H 2 O 2 , low levels of monoiodoacetic acid, diiodoacetic acid, and iodoform were formed, and these levels were enhanced with the increase of iodide concentration. No significant quantities of chloro- or bromo-THMs and HAAs were formed during PAA disinfection treatment. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. DISINFECTION BY-PRODUCTS AND OTHER EMERGING CONTAMINANTS IN DRINKING WATER

    EPA Science Inventory

    Although drinking water disinfection by-products (DBPs) have been studied for the last 30 years, significant, new concerns have arisen. These concerns include adverse reproductive and developmental effects recently observed in human populations, concerns that the types of cancer...

  5. Health research needed to resolve scientific issues surrounding drinking water disinfection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kleffman, D.

    Disinfection of drinking water will most likely continue in the United States in order to prevent exposure to microbial pathogens that can cause infectious disease. However, the emergence of concerns over possible toxicological effects, including cancer, mutagenicity, cardiovascular disease, and reproductive effects, may require that the disinfection techniques used in this country be altered or changed. First, the spectrum of possible health effects and the level of risk posed by exposure to chemicals in drinking water must be determined. This will require a continuing research program to develop the scientific data necessary to resolve these issues. In this paper, themore » authors discusses the microbiological, chemical, toxicological, and epidemiological research that is needed to address these issues.« less

  6. A pulsed light system for the disinfection of flow through water in the presence of inorganic contaminants.

    PubMed

    Garvey, Mary; Rowan, Neil

    2015-06-01

    The use of ultraviolet (UV) light for water disinfection has become increasingly popular due to on-going issues with drinking water and public health. Pulsed UV light has proved to be an effective form of inactivating a range of pathogens including parasite species. However, there are limited data available on the use of pulsed UV light for the disinfection of flowing water in the absence or presence of inorganic contaminants commonly found in water sources. Here, we report on the inactivation of test species including Bacillus endospores following pulsed UV treatment as a flow through system. Significant levels of inactivation were obtained for both retention times tested. The presence of inorganic contaminants iron and/or manganese did affect the rate of disinfection, predominantly resulting in an increase in the levels of inactivation at certain UV doses. The findings of this study suggest that pulsed UV light may provide a method of water disinfection as it successfully inactivated bacterial cells and bacterial endospores in the absence and presence of inorganic contaminants.

  7. Kinetic model of water disinfection using peracetic acid including synergistic effects.

    PubMed

    Flores, Marina J; Brandi, Rodolfo J; Cassano, Alberto E; Labas, Marisol D

    2016-01-01

    The disinfection efficiencies of a commercial mixture of peracetic acid against Escherichia coli were studied in laboratory scale experiments. The joint and separate action of two disinfectant agents, hydrogen peroxide and peracetic acid, were evaluated in order to observe synergistic effects. A kinetic model for each component of the mixture and for the commercial mixture was proposed. Through simple mathematical equations, the model describes different stages of attack by disinfectants during the inactivation process. Based on the experiments and the kinetic parameters obtained, it could be established that the efficiency of hydrogen peroxide was much lower than that of peracetic acid alone. However, the contribution of hydrogen peroxide was very important in the commercial mixture. It should be noted that this improvement occurred only after peracetic acid had initiated the attack on the cell. This synergistic effect was successfully explained by the proposed scheme and was verified by experimental results. Besides providing a clearer mechanistic understanding of water disinfection, such models may improve our ability to design reactors.

  8. [Combined use of active chlorine and coagulants for drinking water purification and disinfection].

    PubMed

    Rakhmanin, Iu A; Zholdakova, Z I; Poliakova, E E; Kir'ianova, L F; Miasnikov, I N; Tul'skaia, E A; Artemova, T Z; Ivanova, L V; Dmitrieva, R A; Doskina, T V

    2004-01-01

    The authors made an experimental study of the efficiency of water purification procedures based on the combined use of active chlorine and coagulants and hygienically evaluated the procedures. The study included the evaluation of water disinfection with various coagulants and active chlorine; the investigation of the processes of production of deleterious organic chlorine compounds; the assessment of the quality of water after its treatment. The coagulants representing aluminum polyoxychloride: RAX-10 (AQUA-AURATE 10) and RAX-18 (AQUA-AURATE 18), and aluminum sulfate, technically pure grade were tested. The treatment of river water with the coagulants RAX-10 and RAX-18, followed by precipitation, filtration, and chlorination under laboratory conditions, was shown to result in water disinfection to the levels complying with the requirements described in SanPiN 2.1.4.1074-01. RAX-18 showed the best disinfecting activity against total and heat-tolerant coliform bacteria, but also to the highly chlorine-resistant microrganisms--the spores of sulfite-reducing Clostridia, phages, and viruses. Since the coagulants have an increased sorptive capacity relative to humus and other organic substances, substitution of primary chlorination for coagulant treatment may induce a reduction in the risk of formation of oncogenically and mutagenically hazardous chlorinated hydrocarbons.

  9. Bench-Scale Evaluation of Peracetic Acid and Twin Oxide ™ as Disinfectants in Drinking Water

    EPA Science Inventory

    Chlorine is widely used as an inexpensive and potent disinfectant in the United States for drinking water. However, chlorine has the potential for forming carcinogenic and mutagenic disinfection by-products (DBPs). In this study, bench scale experiments were conducted at the U.S...

  10. Status report on analytical methods to support the disinfectant/disinfection by-products regulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1992-08-01

    The U.S. EPA is developng national regulations to control disinfectants and disinfection by-products in public drinking water supplies. Twelve disinfectants and disinfection by-products are identified for possible regulation under this rule. The document summarizes the analytical methods that EPA intends to propose as compliance monitoring methods. A discussion of surrogate measurements that are being considered for inclusion in the regulation is also provided.

  11. A NATIONWIDE DRINKING WATER DISINFECTION BY-PRODUCT OCCURRENCE STUDY - IDENTIFICATION OF NEW AND TOXICOLOGICALLY SIGNIFICANT COMPOUNDS WITH MASS SPECTROMETRY

    EPA Science Inventory

    Drinking water disinfection by-products (DBPs) are formed when disinfectants, such as chlorine, react with natural organic matter and bromide present in the water. Chloroform was the first DBP identified in drinking water (in 1974), and was subsequently shown (along with other t...

  12. Ozone Disinfection of Vibrio vulnificus in Shrimp Pond Water

    NASA Astrophysics Data System (ADS)

    Dyah Pita Rengga, Wara; Cahya Julyta Putri, Echa; Wulansarie, Ria; Suryanto, Agus

    2018-03-01

    One variety of shrimp, L.Vanamei, often uses brackish water during the operation in the shrimp pond. Chlorination and ultraviolet are usually used for disinfection of brackish water. However, it is ineffective and forms sediment in the water distribution. It can be a negative impact on the water quality cause a contamination on the shrimp, so the farmers might have loss of profit because Vibrio vulnificus causes infection and dead on the shrimp. It affects the safety of consumers and should be minimized. The purpose of this study is to reduce the number of V. vulnificus bacteria in the pond water. The water was put in the storage tanks then pumped to filter out the impurities of the water. Furthermore, the water set the flow rate in 1 LPM, 2 LPM, and 3 LPM. After that, the ozone was injected to the water flow to sterilize the V. vulnificus bacteria. Finally, the water was returned to the original tank. The water from the tank was taken through a valve and analyzed in 0, 3, 7, 12, 18, 24, 30 minutes. The sample was analyzed immediately using a Total Plate Count method to determine the number of V. vulnificus bacteria in the shrimp pond water. The flow rate shows that the longer time of ozone made a lower amount of Vibrio v. bacteria. In 2 LPM water, it shows the optimum results of V. vulnificus. bacteria reduction for 88.1% compared to the flow rate of 1 LPM and 3 LPM with the bacteria reduction of 68,8% and 70.6%. This study shows that the ozone with a flow rate of 2 LPM circulation is the most effective method to help reducing the number of V. vulnificus in brackish water distribution system in the shrimp environment and potentially as a disinfectant.

  13. Thermal disinfection of hotels, hospitals, and athletic venues hot water distribution systems contaminated by Legionella species.

    PubMed

    Mouchtouri, Varvara; Velonakis, Emmanuel; Hadjichristodoulou, Christos

    2007-11-01

    Legionella spp. (> or = 500 cfu liter(-1)) were detected in 92 of 497 water distribution systems (WDS) examined. Thermal disinfection was applied at 33 WDS. After the first and second application of the disinfection procedure, 15 (45.4%) and 3 (9%) positive for remedial actions WDS were found, respectively. Legionella pneumophila was more resistant to thermal disinfection than Legionella non-pneumophila spp. (relative risk [RR]=5.4, 95% confidence intervals [CI]=1-35). WDS of hotels with oil heater were more easily disinfected than those with electrical or solar heater (RR=0.4 95% CI=0.2-0.8). Thermal disinfection seems not to be efficient enough to eliminate legionellae, unless repeatedly applied and in combination with extended heat flushing, and faucets chlorine disinfection.

  14. Reduction of disinfection by-product precursors in reservoir water by coagulation and ultrafiltration.

    PubMed

    Wang, Feng; Gao, Baoyu; Ma, Defang; Yue, Qinyan; Li, Ruihua; Wang, Qianwen

    2016-11-01

    In this study, reservoir water intended for drinking water supply was treated by (i) ultrafiltration (UF) (ii) coagulation (CW) (iii) coagulation combined with ultrafiltration (CW-UF). To probe the influences of three treatment processes on disinfection byproduct (DBP) precursors in source water, the changes of dissolved organic matter (DOM) amounts and physicochemical properties, and disinfection byproduct (DBP) formation characteristics during chlorine disinfection were investigated. Both carbonaceous DBP (C-DBP) and nitrogenous DBP (N-DBP) formation and speciation were analyzed. The influence of chlorine dose, contact time on DBP formation and speciation were also studied to optimize the disinfection conditions to minimize the DBP formation. Compared with UF and CW alone, CW-UF improved the dissolved organic carbon (DOC) removal from about 20 % to 59 %. The three-dimensional excitation and emission matrix (3DEEM) fluorescence spectroscopy analysis showed that CW-UF had high removal efficiency in microbial products (Region IV), fulvic acid-like (Region III) and humic acid-like (Region V). The total C-DBP was determined by the formation of trihalomethanes and trichloromethane was the most abundant species (40 %). The most abundant N-DBP species was dichloroacetonitrile (32.5 %), followed by trichloroactetonitrile. CW-UF effectively reduced the risk of DBPs in drinking water supply by reducing 30.8 % and 16.9 % DBPs formation potential compared with UF and CW alone. Increasing contact time improved the yields of both C-DBPs and N-DBPs. Chlorine dosage had slight influence on DBP yield in this study.

  15. Formation of disinfection byproducts in typical Chinese drinking water.

    PubMed

    Liu, Wenbo; Zhao, Yanmei; Chow, Christopher W K; Wang, Dongsheng

    2011-01-01

    Eight typical drinking water supplies in China were selected in this study. Both source and tap water were used to investigate the occurrence of chlorinated disinfection byproducts (DBPs), and seasonal variation in the concentrations of trihalomethanes (THMs) of seven water sources was compared. The results showed that the pollution level for source water in China, as shown by DBP formation potential, was low. The most encountered DBPs were chloroform, dichloroacetic acid, trichloroacetic acid, and chlorodibromoacetic acid. The concentration of every THMs and haloacetic acid (HAA) compound was under the limit of standards for drinking water quality. The highest total THMs concentrations were detected in spring.

  16. Differential resistance of drinking water bacterial populations to monochloramine disinfection.

    PubMed

    Chiao, Tzu-Hsin; Clancy, Tara M; Pinto, Ameet; Xi, Chuanwu; Raskin, Lutgarde

    2014-04-01

    The impact of monochloramine disinfection on the complex bacterial community structure in drinking water systems was investigated using culture-dependent and culture-independent methods. Changes in viable bacterial diversity were monitored using culture-independent methods that distinguish between live and dead cells based on membrane integrity, providing a highly conservative measure of viability. Samples were collected from lab-scale and full-scale drinking water filters exposed to monochloramine for a range of contact times. Culture-independent detection of live cells was based on propidium monoazide (PMA) treatment to selectively remove DNA from membrane-compromised cells. Quantitative PCR (qPCR) and pyrosequencing of 16S rRNA genes was used to quantify the DNA of live bacteria and characterize the bacterial communities, respectively. The inactivation rate determined by the culture-independent PMA-qPCR method (1.5-log removal at 664 mg·min/L) was lower than the inactivation rate measured by the culture-based methods (4-log removal at 66 mg·min/L). Moreover, drastic changes in the live bacterial community structure were detected during monochloramine disinfection using PMA-pyrosequencing, while the community structure appeared to remain stable when pyrosequencing was performed on samples that were not subject to PMA treatment. Genera that increased in relative abundance during monochloramine treatment include Legionella, Escherichia, and Geobacter in the lab-scale system and Mycobacterium, Sphingomonas, and Coxiella in the full-scale system. These results demonstrate that bacterial populations in drinking water exhibit differential resistance to monochloramine, and that the disinfection process selects for resistant bacterial populations.

  17. Effects of Disinfectants in Water on Mir- and Earth-Grown Wheat

    NASA Technical Reports Server (NTRS)

    Campbell, William .F.; Bubenheim, D. L.; Bugbee, B.; Salisbury, F. B.; Bingham, G. E.; Levinskikh, M.; Sytchev, V. N.; Ivanova, I.; Chernova, L.; Podolsky, I.

    2002-01-01

    Iodine and silver fluoride are used to purify water onboard U. S. Shuttles and the Russian Space Station, Mir, respectively. In 1995, iodine-treated water, which ranged from 1.0-4.0 mg x kg(exp -1) with a mean of 2.9 mg x kg(exp -1), was applied to Super Dwarf wheat (Triticum aestivum L.) plants when Mir water (grey or tech grade) became scarce. The potential phytotoxicity of iodine on Super Dwarf wheat is an unknown. Since use of iodine-treated water was not part of the experiment, we sought to determine whether it accounted for the subsequent poor wheat seedling growth and floral development onboard the Mir. Super Dwarf wheat seeds were imbibed in iodine or silver fluoride concentrations of 0.0, 1.0, 2.0, 4.0, 8.0 or 16.0 mg x kg(exp -1) for 96 h at 4 C. Five seeds were then planted per 13.3 cm x 13.3 cm pots containing a granular clinoptilolite (Cp) zeolite (1 -2 mm dia.) and placed in Percival(TM) growth chambers programmed for 20/15 C and 18/6 h d/n regime. Plants were irrigated with distilled water, and Iodine- or silver fluoride-treated distilled water. In separate experiments, seeds were treated as above and germination and early seedling growth were determined by examining seedling responses to disinfectants in rolled paper towels. Silver fluoride had very little effect on wheat seed germination. By contrast, iodine reduced germination at all treatment levels. Seedlings exposed to 1.0, 2.0, and 4.0 mg x kg(exp -1) of iodine or silver fluoride levels exhibited a slight stimulation in shoot and root growth. Both disinfectants at 8 and 16 mg x kg(exp -1) showed significantly (p is less than or equal to 0.01) reduced seedling shoot and root lengths and fresh biomasses compared to the control and lower disinfectant levels. The number of spikelets per spike, florets per spikelet, seeds per spike and seed weight were also significantly reduced at the 8 and 16 mg x kg(exp -1) compared to the control and lower levels of disinfectant. Based on these ground

  18. Control of Legionella Contamination and Risk of Corrosion in Hospital Water Networks following Various Disinfection Procedures

    PubMed Central

    Ferranti, Greta; Mansi, Antonella; Marcelloni, Anna M.; Proietto, Anna R.; Saini, Navneet; Borella, Paola; Bargellini, Annalisa

    2016-01-01

    Physical and chemical disinfection methods have been proposed with the aim of controlling Legionella water contamination. To date, the most effective procedures for reducing bacterial contamination have not yet been defined. The aim of this study was to assess the long-term effectiveness of various disinfection procedures in order to reduce both culturable and nonculturable (NC) legionellae in different hospital water networks treated with heat, chlorine dioxide, monochloramine, and hydrogen peroxide. The temperature levels and biocide concentrations that proved to give reliable results were analyzed. In order to study the possible effects on the water pipes, we verified the extent of corrosion on experimental coupons after applying each method for 6 months. The percentage of positive points was at its lowest after treatment with monochloramine, followed by chlorine dioxide, hydrogen peroxide, and hyperthermia. Different selections of Legionella spp. were observed, as networks treated with chlorine-based disinfectants were contaminated mainly by Legionella pneumophila serogroup 1, hyperthermia was associated with serogroups 2 to 14, and hydrogen peroxide treatment was associated mainly with non-pneumophila species. NC cells were detected only in heat-treated waters, and also when the temperature was approximately 60°C. The corrosion rates of the coupons were within a satisfactory limit for water networks, but the morphologies differed. We confirm here that chemical disinfection controls Legionella colonization more effectively than hyperthermia does. Monochloramine was the most effective treatment, while hydrogen peroxide may be a promising alternative to chlorine-based disinfectants due to its ability to select for other, less virulent or nonpathogenic species. PMID:26969696

  19. Emerging nitrogenous disinfection byproducts: Transformation of the antidiabetic drug metformin during chlorine disinfection of water.

    PubMed

    Armbruster, Dominic; Happel, Oliver; Scheurer, Marco; Harms, Klaus; Schmidt, Torsten C; Brauch, Heinz-Jürgen

    2015-08-01

    As an environmental contaminant of anthropogenic origin metformin is present in the high ng/L- up to the low μg/L-range in most surface waters. Residues of metformin may lead to the formation of disinfection by-products during chlorine disinfection, when these waters are used for drinking water production. Investigations on the underlying chemical processes occurring during treatment of metformin with sodium hypochlorite in aqueous medium led to the discovery of two hitherto unknown transformation products. Both substances were isolated and characterized by HPLC-DAD, GC-MS, HPLC-ESI-TOF, (1)H-NMR and single-crystal X-ray structure determination. The immediate major chlorination product is a cyclic dehydro-1,2,4-triazole-derivate of intense yellow color (Y; C4H6ClN5). It is a solid chlorimine of limited stability. Rapid formation was observed between 10 °C and 30 °C, as well as between pH 3 and pH 11, in both ultrapure and tap water, even at trace quantities of reactants (ng/L-range for metformin, mg/L-range for free chlorine). While Y is degraded within a few hours to days in the presence of light, elevated temperature, organic solvents and matrix constituents within tap water, a secondary degradation product was discovered, which is stable and colorless (C; C4H6ClN3). This chloroorganic nitrile has a low photolysis rate in ambient day light, while being resistant to heat and not readily degraded in the presence of organic solvents or in the tap water matrix. In addition, the formation of ammonia, dimethylamine and N,N-dimethylguanidine was verified by cation exchange chromatography. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Sensitivity of free-living amoeba trophozoites and cysts to water disinfectants.

    PubMed

    Dupuy, Mathieu; Berne, Florence; Herbelin, Pascaline; Binet, Marie; Berthelot, Nelsie; Rodier, Marie-Hélène; Soreau, Sylvie; Héchard, Yann

    2014-03-01

    Free-living amoebae are naturally present in water. These protozoa could be pathogenic and could also shelter pathogenic bacteria. Thus, they are described as a potential hazard for health. Also, free-living amoebae have been described to be resistant to biocides, especially under their cyst resistant form. There are several studies on amoeba treatments but none of them compare sensitivity of trophozoites and cysts from different genus to various water disinfectants. In our study, we tested chlorine, monochloramine and chlorine dioxide on both cysts and trophozoites from three strains, belonging to the three main genera of free-living amoebae. The results show that, comparing cysts to trophozoites inactivation, only the Acanthamoeba cysts were highly more resistant to treatment than trophozoites. Comparison of the disinfectant efficiency led to conclude that chlorine dioxide was the most efficient treatment in our conditions and was particularly efficient against cysts. In conclusion, our results would help to adapt water treatments in order to target free-living amoebae in water networks. Copyright © 2013 Elsevier GmbH. All rights reserved.

  1. Removal of estrogens through water disinfection processes and formation of by-products.

    PubMed

    Pereira, Renata Oliveira; Postigo, Cristina; de Alda, Miren López; Daniel, Luiz Antonio; Barceló, Damià

    2011-02-01

    Estrogens constitute a recognized group of environmental emerging contaminants which have been proven to induce estrogenic effects in aquatic organisms exposed to them. Low removal efficiency in wastewater treatment plants results in the presence of this type of contaminants in surface waters and also even in finished drinking water. This manuscript reviews the environmental occurrence of natural (estrone, estradiol and estriol) and synthetic (ethynyl estradiol) estrogens in different water matrices (waste, surface, ground and drinking water), and their removal mainly via chemical oxidative processes. Oxidative treatments have been observed to be very efficient in eliminating estrogens present in water; however, disinfection by-products (DBPs) are generated during the process. Characterization of these DBPs is essential to assess the risk that drinking water may potentially pose to human health since these DBPs may also have endocrine disrupting properties. This manuscript reviews the DBPs generated during oxidative processes identified so far in the literature and the estrogenicity generated by the characterized DBPs and/or by the applied disinfection technology. Copyright © 2010 Elsevier Ltd. All rights reserved.

  2. [Disinfection efficiency of peracetic acid, alone and in combination with hypochlorite, against Mycobacterium avium in drinking water].

    PubMed

    Schiavano, G F; Sisti, M; De Santi, M; Brandi, G

    2006-01-01

    Peracetic acid (PAA) is a disinfectant with a wide spectrum of antimicrobial activity, but little is known about the feasibility of using it in the field of drinking water treatment. The aim of this study has been assess disinfectant efficacy of PAA, alone or in combination with hypochlorite, against M. avium in drinking water M. avium is a common opportunistic pathogen in immunocompromised subjects that is able to survive and grow in drinking water distribution systems. In this study PAA did not show appreciable activity against the greater number of tested strains (16/21) up to 5 ppm of PAA, a weak activity was seen on 4 strains, while a significant reduction in viable cells (about 50%) was seen only on 1 strain after 48 h of treatment with 5 ppm of PAA. We also evidenced that M. avium was unaffected by chlorine concentration usually present in drinking water distribution system. Finally, the combination of PAA and sodium hypochlorite did not promote enhanced antimicrobial efficacy respect to the single disinfectants. In conclusion, our result would indicate that PAA is an unlikely candidate for the disinfection of drinking water from M. avium and further strategies are required to eliminate M. avium from drinking water system.

  3. TIC-Tox: A preliminary discussion on identifying the forcing agents of DBP-mediated toxicity of disinfected water.

    PubMed

    Plewa, Michael J; Wagner, Elizabeth D; Richardson, Susan D

    2017-08-01

    The disinfection of drinking water is a major public health achievement; however, an unintended consequence of disinfection is the generation of disinfection by-products (DBPs). Many of the identified DBPs exhibit in vitro and in vivo toxicity, generate a diversity of adverse biological effects, and may be hazards to the public health and the environment. Only a few DBPs are regulated by several national and international agencies and it is not clear if these regulated DBPs are the forcing agents that drive the observed toxicity and their associated health effects. In this study, we combine analytical chemical and biological data to resolve the forcing agents associated with mammalian cell cytotoxicity of drinking water samples from three cities. These data suggest that the trihalomethanes (THMs) and haloacetic acids may be a small component of the overall cytotoxicity of the organic material isolated from disinfected drinking water. Chemical classes of nitrogen-containing DBPs, such as the haloacetonitriles and haloacetamides, appear to be the major forcing agents of toxicity in these samples. These findings may have important implications for the design of epidemiological studies that primarily rely on the levels of THMs to define DBP exposure among populations. The TIC-Tox approach constitutes a beginning step in the process of identifying the forcing agents of toxicity in disinfected water. Copyright © 2017. Published by Elsevier B.V.

  4. Formation and occurrence of new polar iodinated disinfection byproducts in drinking water.

    PubMed

    Pan, Yang; Li, Wenbin; An, Hao; Cui, Hao; Wang, Ying

    2016-02-01

    During drinking water disinfection, iodinated disinfection byproducts (I-DBPs) can be generated through reactions between iodide, disinfectants, and natural organic matter. Drinking water I-DBPs have been increasingly attracting attention as emerging organic pollutants as a result of their significantly higher toxicity and growth inhibition than their chloro- and bromo-analogues. In this study, by adopting ultra performance liquid chromatography/electrospray ionization-triple quadrupole mass spectrometry precursor ion scan, multiple reaction monitoring, and product ion scan analyses, 11 new polar I-DBPs with confirmed structures and eight new polar I-DBPs with proposed structures were detected in simulated drinking water samples. Chloramination of simulated raw waters containing natural organic matter with higher aromaticity produced higher levels of new phenolic I-DBPs. Formation of new polar I-DBPs and total organic iodine (TOI) was most favored in chloramination, followed by chlorine dioxide treatment, and relatively minor in chlorination. Lower pH in chloramination substantially enhanced the formation of new polar I-DBPs and TOI. NH2Cl and dissolved organic nitrogen could be important nitrogen sources and precursors for formation of the two new nitrogenous phenolic I-DBPs. Notably, in tap water samples collected from nine major cities located in the Yangtze River Delta region of China, seven of the 11 new polar I-DBPs with confirmed structures were detected at levels from 0.11 to 28 ng/L, and the two new nitrogenous phenolic I-DBPs were ubiquitous with concentrations from 0.12 to 24 ng/L, likely due to the relatively high dissolved organic nitrogen levels in regional source waters. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Quaternary ammonium compounds: an alternative disinfection method for fresh produce wash water.

    PubMed

    Chaidez, Cristobal; Lopez, Javier; Castro-del Campo, Nohelia

    2007-06-01

    Irrigation water can serve as a vehicle for transporting pathogenic microorganisms, and numerous cases of bacterial infections from consumption of irrigated fresh produce have been reported in recent years. Chlorine-based disinfectants applied when produce is packed are widely used to control microorganisms. When applied properly, the chlorine products are effective. However, hazardous disinfection breakdown products can be formed, and chlorine disinfectants have high oxidant activity that can affect produce quality and pose a risk to food handlers. Quaternary Ammonium Compounds (QACs) are a disinfectant alternative for the washing of fruits and vegetables. They can control a great number of microorganisms, have low toxicity when used at recommended doses, and are stable in storage. The purpose of this work was to assess the disinfectant activity of QACs against Escherichia coli and Staphylococcus aureus under worst-case and average-case turbidity conditions, (2 and 100 nephelometric units); two disinfectant concentrations (100 and 200 mg/L; and two contact times (30 and 120 seconds). Our research showed that QACs were effective against both bacteria. The percentage reduction of Escherichia coli was significantly higher in the less turbid solution (P = 0.027), while turbidity did not affect the reduction of Staphylococcus aureus (P > 0.05). E. coli was more resistant to QAC treatment than S. aureus. Based on the data obtained we can conclude that QACs could be an alternative in washing processes of fruits and vegetables.

  6. DISINFECTION BYPRODUCTS: THE NEXT GENERATION

    EPA Science Inventory

    Disinfection of drinking water is rightly hailed as a major public health triumph of the 20th Century. Before widespread disinfection of drinking water in the U.S. and Europe, millions of people died from infectious waterborne diseases, such as typhoid and cholera. The microbia...

  7. Exposure estimates to disinfection by-products of chlorinated drinking water.

    PubMed

    Weisel, C P; Kim, H; Haltmeier, P; Klotz, J B

    1999-02-01

    Exposure to disinfection by-products (DBPs) of drinking water is multiroute and occurs in households serviced by municipal water treatment facilities that disinfect the water as a necessary step to halt the spread of waterborne infectious diseases. Biomarkers of the two most abundant groups of DBPs of chlorination, exhaled breath levels of trihalomethanes (THMs) and urinary levels of two haloacetic acids, were compared to exposure estimates calculated from in-home tap water concentrations and responses to a questionnaire related to water usage. Background THM breath concentrations were uniformly low. Strong relationships were identified between the THM breath concentrations collected after a shower and both the THM water concentration and the THM exposure from a shower, after adjusting for the postshower delay time in collecting the breath sample. Urinary haloacetic acid excretion rates were not correlated to water concentrations. Urinary trichloroacetic acid excretion rates were correlated with ingestion exposure, and that correlation was stronger in a subset of individuals who consumed beverages primarily within their home where the concentration measurements were made. No correlation was observed between an average 48-hr exposure estimate and the urinary dichloroacetic acid excretion rate, presumably because of its short biological half-life. Valid biomarkers were identified for DBP exposures, but the time between the exposure and sample collection should be considered to account for different metabolic rates among the DBPs. Further, using water concentration as an exposure estimate can introduce misclassification of exposure for DBPs whose primary route is ingestion due to the great variability in the amount of water ingested across a population.

  8. Life cycle environmental and economic implications of small drinking water system upgrades to reduce disinfection byproducts.

    PubMed

    Mo, Weiwei; Cornejo, Pablo K; Malley, James P; Kane, Tyler E; Collins, M Robin

    2018-06-20

    Many of the small drinking water systems in the US that utilize simple filtration and chlorine disinfection or chlorine disinfection alone are facing disinfection byproduct (DBP) noncompliance issues, which need immediate upgrades. In this study, four potential upgrade scenarios, namely the GAC, ozone, UV30, and UV186 scenarios, were designed for a typical small drinking water systems and compared in terms of embodied energy, carbon footprint, and life cycle cost. These scenarios are designed to either reduce the amount of DBP precursors using granular activated carbon filtration (the GAC scenario) or ozonation (the ozone scenario), or replace the chlorine disinfection with the UV disinfection at different intensities followed by chloramination (the UV30 and UV186 scenarios). The UV30 scenario was found to have the lowest embodied energy (417 GJ/year) and life cycle cost ($0.25 million US dollars), while the GAC scenario has the lowest carbon footprint (21 Mg CO 2 e/year). The UV186 scenario consistently presents the highest environmental and economic impacts. The major contributors of the economic and environmental impacts of individual scenarios also differ. Energy and/or material consumptions during the operation phase dominate the environmental impacts of the four scenarios, while the infrastructure investments have a noticeable contribution to the economic costs. The results are sensitive to changes in water quality. An increase of raw water quality, i.e., an increase in organic precursor content, could potentially result in the ozone scenario being the least energy intensive scenario, while a decrease of water quality could greatly reduce the overall competitiveness of the GAC scenario. Copyright © 2018 Elsevier Ltd. All rights reserved.

  9. Control of Legionella Contamination and Risk of Corrosion in Hospital Water Networks following Various Disinfection Procedures.

    PubMed

    Marchesi, Isabella; Ferranti, Greta; Mansi, Antonella; Marcelloni, Anna M; Proietto, Anna R; Saini, Navneet; Borella, Paola; Bargellini, Annalisa

    2016-05-15

    Physical and chemical disinfection methods have been proposed with the aim of controlling Legionella water contamination. To date, the most effective procedures for reducing bacterial contamination have not yet been defined. The aim of this study was to assess the long-term effectiveness of various disinfection procedures in order to reduce both culturable and nonculturable (NC) legionellae in different hospital water networks treated with heat, chlorine dioxide, monochloramine, and hydrogen peroxide. The temperature levels and biocide concentrations that proved to give reliable results were analyzed. In order to study the possible effects on the water pipes, we verified the extent of corrosion on experimental coupons after applying each method for 6 months. The percentage of positive points was at its lowest after treatment with monochloramine, followed by chlorine dioxide, hydrogen peroxide, and hyperthermia. Different selections of Legionella spp. were observed, as networks treated with chlorine-based disinfectants were contaminated mainly by Legionella pneumophila serogroup 1, hyperthermia was associated with serogroups 2 to 14, and hydrogen peroxide treatment was associated mainly with non-pneumophila species. NC cells were detected only in heat-treated waters, and also when the temperature was approximately 60°C. The corrosion rates of the coupons were within a satisfactory limit for water networks, but the morphologies differed. We confirm here that chemical disinfection controls Legionella colonization more effectively than hyperthermia does. Monochloramine was the most effective treatment, while hydrogen peroxide may be a promising alternative to chlorine-based disinfectants due to its ability to select for other, less virulent or nonpathogenic species. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  10. Solar photolysis of soluble microbial products as precursors of disinfection by-products in surface water.

    PubMed

    Wu, Jie; Ye, Jian; Peng, Huanlong; Wu, Meirou; Shi, Weiwei; Liang, Yongmei; Liu, Wei

    2018-06-01

    In the Pearl River Delta area, the upstream municipal wastewater is commonly discharged into rivers which are a pivotal source of downstream drinking water. Solar irradiation transforms some of the dissolved organic matter discharged from the wastewater, also affecting the formation of disinfection by-products in subsequent drinking water treatment plants. The effect of simulated solar radiation on soluble microbial products extracted from activated sludge was documented in laboratory experiments. Irradiation was found to degrade macromolecules in the effluent, yielding smaller, more reactive intermediate species which reacted with chlorine or chloramine to form higher levels of noxious disinfection by-products. The soluble microbial products were found to be more active in formation of disinfection by-products regard than naturally-occurring organic matter. The results show that solar irradiation induced the formation of more trihalomethane (THMs), chloral hydrate (CH) and trichloronitromethane (TCNM), causing greater health risks for downstream drinking water. Copyright © 2018 Elsevier Ltd. All rights reserved.

  11. Rapid disinfection of E-Coliform contaminated water using WO3 semiconductor catalyst by laser-induced photo-catalytic process.

    PubMed

    Gondal, Mohammed A; Khalil, Amjad

    2008-04-01

    Laser-induced photo-catalysis process using WO(3) semiconductor catalyst was applied for the study of disinfection effectiveness of E-coliform-contaminated water. For this purpose, wastewater polluted with E-coliform bacteria was exposed to 355 nm UV radiations generated by third harmonic of Nd: YAG laser in special glass cell with and without WO(3) catalyst. E-Coliform quantification was performed by direct plating method to obtain the efficiency of each disinfection treatment. The dependence of disinfection process on laser irradiation energy, amount of catalyst and duration of laser irradiation was also investigated. The disinfection with WO(3) was quite efficient inactivating E-coliforms. For inactivation of E-coliforms, less than 8 minutes' laser irradiation was required, so that, the treated water complies with the microbial standards for drinking water. This study opens the possibility of application of this simple method in rural areas of developing countries using solar radiation.

  12. Alternative Electrode Materials and Ceramic Filter Minimize Disinfection Byproducts in Point-of-Use Electrochemical Water Treatment

    PubMed Central

    Yoon, Yeojoon; Jung, Youmi; Kwon, Minhwan; Cho, Eunha; Kang, Joon-Wun

    2013-01-01

    Abstract Effects of various electrodes and prefiltration to minimize disinfection byproducts (DBPs) in electrochemical water disinfection was evaluated. The target microorganism, Escherichia coli O157:H7, was effectively inactivated even applying a solar-charged storage battery for the electrolysis process. Extent of microbial inactivation decreased with lower water temperature and higher pH in the free chlorine disinfection system. The RuO2/Ti electrode was most efficient because it produced the lowest concentration of chlorate and the highest generation of free chlorine. Prefiltration using a ceramic filter inhibited formation of halogenated DBPs because it removed precursors of DBPs. For safe point-of-use water treatment, the use of a hybrid prefiltration stage with the electrolysis system is strongly recommended to reduce risks from DBPs. The system is particularly suited to use in developing regions. PMID:24381482

  13. SURVEY OF HALONITROMETHANES AND IODOMETHANES: DISINFECTION BY-PRODUCTS IN DRINKING WATER

    EPA Science Inventory

    This project involves the study of two classes of chemicals, halonitromethanes and iodomethanes, which have been found to be drinking water disinfection by-products (DBPs). Both have been predicted to have toxicity. In toxicity screening tests, bromonitromethanes have been shown ...

  14. Disinfection of waterborne viruses using silver nanoparticle-decorated silica hybrid composites in water environments.

    PubMed

    Park, SungJun; Ko, Young-Seon; Jung, Haeyong; Lee, Cheonghoon; Woo, Kyoungja; Ko, GwangPyo

    2018-06-01

    Silver nanoparticles (AgNPs) have been reported as an effective alternative for controlling a broad-spectrum of pathogenic viruses. We developed a micrometer-sized silica hybrid composite decorated with AgNPs (AgNP-SiO 2 ) to prevent the inherent aggregation of AgNPs, and facilitated their recovery from environmental media after use. The production process had a high-yield, and fabrication was cost-effective. We evaluated the antiviral capabilities of Ag30-SiO 2 particles against two model viruses, bacteriophage MS2 and murine norovirus (MNV), in four different types of water (deionized, tap, surface, and ground). MNV was more susceptible to Ag30-SiO 2 particles in all four types of water compared to MS2. Furthermore, several water-related factors, including temperature and organic matter content, were shown to affect the antimicrobial capabilities of Ag30-SiO 2 particles. The modified Hom model was the best-fit disinfection model for MNV disinfection in the different types of water. Additionally, this study demonstrated that the effects of a certain level of physical obstacles in water were negligible in regards to the use of Ag30-SiO 2 particles. Thus, effective use of AgNPs in water disinfection processes can be achieved using our novel hybrid composites to inactivate various waterborne viruses. Copyright © 2018 Elsevier B.V. All rights reserved.

  15. Quality and disinfection trials of consumption water in storage reservoirs for rural area in the Marrakech region (Assif El Mal).

    PubMed

    Aziz, Faissal; Mandi, Laila; Boussaid, Abdellatif; Boraam, Fatima; Ouazzani, Naaila

    2013-03-01

    Traditional reservoirs for water storage are important systems of water supply in rural areas of Morocco. These reservoirs are fed by rainwater and/or directly from rivers through open channels; the stored water is used without any treatment as drinking water by the surrounding population. The present study aimed to assess the physicochemical and bacteriological quality of stored water and the corresponding sediment in six traditional reservoirs (R1 to R6) located in the rural municipality of Assif El Mal. We tested two inexpensive methods of disinfecting the stored water: chlorination and solar disinfection in bottles. The results show a rise of organic and mineral concentrations. Regarding bacteriological quality, a critical contamination level was detected (8 × 10(5) CFU/100 ml in water and 9 × 10(7) CFU/g in sediment) according to the 2002 Moroccan Standards for drinking water (0 CFU/100 ml). In the disinfection tests, chlorine disinfection removed all studied germs after just 1 hour, and the solar exposure process removed the majority of bacteria (after 3 hours) except those with a resistant form (Clostridia).

  16. Use of peracetic acid to disinfect water: toxicity to fish

    USDA-ARS?s Scientific Manuscript database

    There has been strong interest in aquaculture for the use of peracetic acid (PAA) as a disinfectant to prevent freshwater fish pathogens. PAA is a stabilized mixture of acetic acid, hydrogen peroxide and water that does not leave dangerous residues in the environment when it breaks down as most com...

  17. Electrochemical disinfection of bacteria-laden water using antimony-doped tin-tungsten-oxide electrodes.

    PubMed

    Ghasemian, Saloumeh; Asadishad, Bahareh; Omanovic, Sasha; Tufenkji, Nathalie

    2017-12-01

    Electrochemical disinfection has been shown to be an efficient method with a shortrequired contact time for treatment of drinking water supplies, industrial raw water supplies, liquid foodstuffs, and wastewater effluents. In the present work, the electrochemical disinfection of saline water contaminated with bacteria was investigated in chloride-containing solutions using Sb-doped Sn 80% -W 20% -oxide anodes. The influence of current density, bacterial load, initial chloride concentration, solution pH, and the type of bacteria (E. coli D21, E. coli O157:H7, and E. faecalis) on disinfection efficacy was systematically examined. The impact of natural organic matter and a radical scavenger on the disinfection process was also examined. The electrochemical system was highly effective in bacterial inactivation for a 0.1 M NaCl solution contaminated with ∼10 7  CFU/mL bacteria by applying a current density ≥1 mA/cm 2 through the cell.100% inactivation of E. coli D21 was achieved with a contact time of less than 60 s and power consumption of 48 Wh/m 3 , by applying a current density of 6 mA/cm 2 in a 0.1 M NaCl solution contaminated with ∼10 7 CFU/mL. Reactive chlorine species as well as reactive oxygen species (e.g. hydroxyl radicals) generated in situ during the electrochemical process were determined to be responsible for inactivation of bacteria. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. THE TOXICOLOGY OF COMPLEX MIXTURES OF DISINFECTION BY-PRODUCTS

    EPA Science Inventory

    Chemical disinfection of water is a major public health advance that has decreased dramatically water-borne disease. Chemical disinfectants react with naturally occurring organic and inorganic matter in water to produce a wide variety of disinfection byproducts (DBPs). DBP num...

  19. UV/TiO2 photocatalytic disinfection of carbon-bacteria complexes in activated carbon-filtered water: Laboratory and pilot-scale investigation.

    PubMed

    Zhao, Jin Hui; Chen, Wei; Zhao, Yaqian; Liu, Cuiyun; Liu, Ranbin

    2015-01-01

    The occurrence of carbon-bacteria complexes in activated carbon filtered water has posed a public health problem regarding the biological safety of drinking water. The application of combined process of ultraviolet radiation and nanostructure titanium dioxide (UV/TiO2) photocatalysis for the disinfection of carbon-bacteria complexes were assessed in this study. Results showed that a 1.07 Lg disinfection rate can be achieved using a UV dose of 20 mJ cm(-2), while the optimal UV intensity was 0.01 mW cm(-2). Particle sizes ≥8 μm decreased the disinfection efficiency, whereas variation in particle number in activated carbon-filtered water did not significantly affect the disinfection efficiency. Photoreactivation ratio was reduced from 12.07% to 1.69% when the UV dose was increased from 5 mJ cm(-2) to 20 mJ cm(-2). Laboratory and on-site pilot-scale experiments have demonstrated that UV/TiO2 photocatalytic disinfection technology is capable of controlling the risk posed by carbon-bacteria complexes and securing drinking water safety.

  20. INVESTIGATION OF DISINFECTION BY-PRODUCTS IN DRINKING WATER USING SOLID-PHASE EXTRACTION AND GAS CHROMATOGRAPHY/MASS SPECTROMETRY

    EPA Science Inventory

    Disinfection by-products (DBPs) result from the interaction of natural organic matter and bromide with chemical disinfectants, such as chlorine, added to drinking water to inactivate disease-producing microorganisms. These DBPs are monitored and regulated because of their possibl...

  1. Non-PRASA Drinking Water Research on UV Disinfection in Puerto Rico

    EPA Science Inventory

    The U.S. EPA and InterAmerican University of San German worked with water treatment operators from Patillas, Puerto Rico on the installation, training and testing of pretreatment/UV disinfection systems in the communities of La Sofia and Apeadero. This presentation provides path...

  2. INTEGRATED TECHNOLOGY-BASED TOXICOLOGY STUDIES ON DRINKING WATER DISINFECTION BYPRODUCTS (DBPS)

    EPA Science Inventory

    DBPs are formed by reactions of chemical disinfectants with natural organic matter in the source water. Although more than 300 DBPs are known, many remain unidentified; for chlorination, known DBPs account for ~50% of the mass of total organic halide. Toxicological evaluation o...

  3. Effect of disinfectant, water age, and pipe material on occurrence and persistence of Legionella, mycobacteria, Pseudomonas aeruginosa, and two amoebas.

    PubMed

    Wang, Hong; Masters, Sheldon; Hong, Yanjuan; Stallings, Jonathan; Falkinham, Joseph O; Edwards, Marc A; Pruden, Amy

    2012-11-06

    Opportunistic pathogens represent a unique challenge because they establish and grow within drinking water systems, yet the factors stimulating their proliferation are largely unknown. The purpose of this study was to examine the influence of pipe materials, disinfectant type, and water age on occurrence and persistence of three opportunistic pathogens (Legionella pneumophila, Mycobacterium avium, and Pseudomonas aeruginosa), broader genera (Legionella and mycobacteria), and two amoeba hosts (Acanthamoeba spp. and Hartmanella vermiformis). Triplicate simulated distribution systems (SDSs) compared iron, cement, and PVC pipe materials fed either chlorinated or chloraminated tap water and were sampled at water ages ranging from 1 day to 5.7 days. Quantitative polymerase chain reaction quantified gene copies of target microorganisms in both biofilm and bulk water. Legionella, mycobacteria, P. aeruginosa, and both amoebas naturally colonized the six SDSs, but L. pneumophila and M. avium were not detected. Disinfectant type and dose was observed to have the strongest influence on the microbiota. Disinfectant decay was noted with water age, particularly in chloraminated SDSs (due to nitrification), generally resulting in increased microbial detection frequencies and densities with water age. The influence of pipe material became apparent at water ages corresponding to low disinfectant residual. Each target microbe appeared to display a distinct response to disinfectant type, pipe materials, water age, and their interactions. Differences between the first and the second samplings (e.g., appearance of Legionella, reduction in P. aeruginosa and Acanthamoeba) suggest a temporally dynamic drinking water microbial community.

  4. Ultraviolet disinfection of water for small water supplies

    NASA Astrophysics Data System (ADS)

    Carlson, D. A.; Seabloom, R. W.; Dewalle, F. B.; Wetzler, T. F.; Engeset, J.

    1985-07-01

    In the study ultraviolet radiation was considered as an alternative means of disinfection of small drinking water supplies. A major impetus for the study was the large increase in waterborne disease episodes in the United States whose etiologic agent, Giardia lamblia, was found to be highly resistant to conventional chlorination. While the germicidal effect of sunlight has long been known, it has been found that artificial UV radiation with a wavelength of 253.7 nm, can be produced by low pressure mercury vapor lamps. The inactivation of microorganisms by UV radiation is based upon photochemical reactions in DNA which result in errors in the coding system. Inactivation of microorganisms due to exposure to UV is proportional to the intensity multiplied by the time of exposure.

  5. Antimicrobial-Coated Granules for Disinfecting Water

    NASA Technical Reports Server (NTRS)

    Akse, James R.; Holtsnider, John T.; Kliestik, Helen

    2011-01-01

    Methods of preparing antimicrobialcoated granules for disinfecting flowing potable water have been developed. Like the methods reported in the immediately preceding article, these methods involve chemical preparation of substrate surfaces (in this case, the surfaces of granules) to enable attachment of antimicrobial molecules to the surfaces via covalent bonds. A variety of granular materials have been coated with a variety of antimicrobial agents that include antibiotics, bacteriocins, enzymes, bactericides, and fungicides. When employed in packed beds in flowing water, these antimicrobial-coated granules have been proven effective against gram-positive bacteria, gram-negative bacteria, fungi, and viruses. Composite beds, consisting of multiple layers containing different granular antimicrobial media, have proven particularly effective against a broad spectrum of microorganisms. These media have also proven effective in enhancing or potentiating the biocidal effects of in-line iodinated resins and of very low levels of dissolved elemental iodine.

  6. 40 CFR 141.172 - Disinfection profiling and benchmarking.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Enhanced Filtration and Disinfection-Systems Serving 10,000 or More People § 141.172 Disinfection profiling and benchmarking. (a... 40 Protection of Environment 22 2010-07-01 2010-07-01 false Disinfection profiling and...

  7. Disinfection of drain water of tomato by means of UV radiation and slow sand filtration in real greenhouse circumstances.

    PubMed

    De Rocker, E; Goen, K; Van Poucke, K

    2006-01-01

    The efficiency of the disinfection of drain water was tested at 11 greenhouses with tomato cultivation on rockwool substrate in Flanders (Belgium) by means of mycological analysis. In addition the presence of phytopathogenic fungi in the drain water was analysed at 2 supplementary greenhouses with recirculation without disinfection.

  8. MODELING CHLORINE DECAY AND THE FORMATION OF DISINFECTION BY-PRODUCTS (DBPS) IN DRINKING WATER

    EPA Science Inventory

    A major objective of drinking water treatment is to provide microbiologically safe drinking water. The combination of conventional drinking water treatment and disinfection has proved to be one of the major public health advances in modern times. In the US, chlorine is most often...

  9. Solar Disinfection Improves Drinking Water Quality to Prevent Diarrhea in Under-Five Children in Sikkim, India

    PubMed Central

    Rai, BB; Pal, Ranabir; Kar, Sumit; Tsering, Dechen C

    2010-01-01

    Background: Solar radiations improve the microbiological quality of water and offer a method for disinfection of drinking water that requires few resources and no expertise and may reduce the prevalence of diarrhea among under-five children. Aims and Objectives: To find out the reduction in the prevalence of diarrhea in the under-five children after consumption of potable water treated with solar disinfection method. Materials and Methods: This was a population-based interventional prospective study in the urban slum area of Mazegoan, Jorethang, south Sikkim, during the period 1st May 2007 to 30th November 2007 on 136 children in the under-five age group in 102 households selected by random sampling. Main outcome measure was the assessment of the reduction of the prevalence of diarrhea among under-five children after consumption of potable water treated with solar disinfection method practiced by the caregivers in the intervention group keeping water in polyethylene terephthalate (PET) bottles as directed by the investigators. The data were collected by the interview method using a pre-tested questionnaire prepared on the basis of socio-demographics and prevalence of diarrhea. The data were subjected to percentages and chi-square tests, which were used to find the significance. Results: After four weeks of intervention among the study group, the diarrhea prevalence was 7.69% among solar disinfection (SODIS) users, while 31.82% prevalence was observed among non-users in that period; the reduction in prevalence of diarrhea was 75.83%. After eight weeks of intervention, the prevalence of diarrhea was 7.58% among SODIS users and 31.43% among non-users; the reduction in diarrhea was 75.88% in the study group. The findings were found to be statistically significant. Conclusions: In our study, we observed that the prevalence of diarrhea decreased significantly after solar disinfection of water was practiced by the caregivers keeping potable water in PET bottles in the

  10. DEVELOPMENT OF A RESEARCH STRATEGY FOR INTEGRATED TECHNOLOGY-BASED-TOXICOLOGICAL AND CHEMICAL EVALUATION OF COMPLEX MIXTURES OF DRINKING WATER DISINFECTION BYPRODUCTS

    EPA Science Inventory


    Chemical disinfection of water is a major public health triumph of the 20th century. Dramatic decreases in both morbidity and mortality of water-borne diseases are a direct result of water disinfection. With these important public health benefits comes low-level, chronic ex...

  11. Study of Disinfectant Penetration in a Drinking Water Storage Tank Sediment Using Microelectrodes- Indianapolis

    EPA Science Inventory

    Sediment accumulation in water storage facilities causes water quality degradation issues, including enhanced biological growth and more rapid disinfectant decay. For chloramine systems, sediment may harbor nitrifying bacteria, feeding on ammonia from monochloramine decay and dem...

  12. Household Water Disinfection in Hurricane-Affected Communities of Louisiana: Implications for Disaster Preparedness for the General Public

    PubMed Central

    Ram, Pavani K.; Blanton, Elizabeth; Klinghoffer, Debra; Platek, Mary; Piper, Janet; Straif-Bourgeois, Susanne; Bonner, Matthew R.; Mintz, Eric D.

    2007-01-01

    Objectives. Thousands of Louisiana residents were asked to boil water because of widespread disruptions in electricity and natural gas services after Hurricane Rita. We sought to assess awareness of boil water orders and familiarity with household water disinfection techniques other than boiling. Methods. We conducted a cross-sectional survey in randomly selected mobile home communities in Louisiana. Results. We interviewed 196 respondents from 8 communities, which had boil water orders instituted. Of 97 who were home while communities were still under orders to boil water, 30 (31%) were aware of the orders and, of those, 24 (80%) said the orders were active while they were living at home; of the 24, 10 (42%) reported boiling water. Overall, 163 (83%) respondents were aware of a method of water disinfection at the household level: boiling (78%), chlorination (27%), and filtration (25%); 87% had a container of chlorine bleach at home. Conclusions. Few hurricane-affected respondents were aware of boil water orders and of alternate water disinfection techniques. Most had access to chlorine and could have practiced household chlorination if disruption in natural gas and electricity made boiling impossible. PMID:17413065

  13. Exposure estimates to disinfection by-products of chlorinated drinking water.

    PubMed Central

    Weisel, C P; Kim, H; Haltmeier, P; Klotz, J B

    1999-01-01

    Exposure to disinfection by-products (DBPs) of drinking water is multiroute and occurs in households serviced by municipal water treatment facilities that disinfect the water as a necessary step to halt the spread of waterborne infectious diseases. Biomarkers of the two most abundant groups of DBPs of chlorination, exhaled breath levels of trihalomethanes (THMs) and urinary levels of two haloacetic acids, were compared to exposure estimates calculated from in-home tap water concentrations and responses to a questionnaire related to water usage. Background THM breath concentrations were uniformly low. Strong relationships were identified between the THM breath concentrations collected after a shower and both the THM water concentration and the THM exposure from a shower, after adjusting for the postshower delay time in collecting the breath sample. Urinary haloacetic acid excretion rates were not correlated to water concentrations. Urinary trichloroacetic acid excretion rates were correlated with ingestion exposure, and that correlation was stronger in a subset of individuals who consumed beverages primarily within their home where the concentration measurements were made. No correlation was observed between an average 48-hr exposure estimate and the urinary dichloroacetic acid excretion rate, presumably because of its short biological half-life. Valid biomarkers were identified for DBP exposures, but the time between the exposure and sample collection should be considered to account for different metabolic rates among the DBPs. Further, using water concentration as an exposure estimate can introduce misclassification of exposure for DBPs whose primary route is ingestion due to the great variability in the amount of water ingested across a population. Images Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Figure 6 PMID:9924004

  14. THE ROLE OF GC/MS AND LC/MS IN THE DISCOVERY OF DRINKING WATER DISINFECTION BY-PRODUCTS

    EPA Science Inventory

    Gas chromatography/mass spectrometry (GC/MS) has played a pivotal role in the discovery of disinfection by-products (DBPs) in drinking water. DBPs are formed when disinfectants, such as chlorine, ozone, chlorine dioxide, or chloramine, react with natural organic matter in the ...

  15. THE ROLE OF GC-MS AND LC-MS IN THE DISCOVERY OF DRINKING WATER DISINFECTION BY-PRODUCTS

    EPA Science Inventory

    Gas chromatography-mass spectrometry (GC-MS) has played a pivotal role in the discovery of disinfection by-products (DBPs) in drinking water. DBPs are formed when disinfectants, such as chlorine, ozone, chlorine dioxide or chloramine, react with natural organic matter in the wate...

  16. Progressive Increase in Disinfection Byproducts and Mutagenicity from Sourceto Tap to Swimming Pool and Spa Water: Implications for Public Health

    EPA Science Inventory

    Pools and spas are enjoyed throughout the world for exercise and relaxation. However, there are no previous studies on the mutagenicity of disinfected spa (hot tub) waters or comprehensive identification of disinfection byproducts (DBPs) formed in spas. Using 28 water samples f...

  17. Demonstration of the Enhanced Disinfection of E. coli Water Contamination by Associated Solar Irradiation with Potassium Persulfate

    PubMed Central

    GHANIZADEH, Ghader; NASERI ARA, Ali; ESMAILI, Davoud; MASOUMBEIGI, Hossein

    2015-01-01

    Background: Tremendous amount of researches have investigated the issue of water photodisnfection. The aim of this research is to illustrate the influences of bacterial density, turbidity, exposure time and potassium persulfate (KPS) dosage on the efficacy of associated solar disinfection (SODIS) with KPS for E. coli (ATCC: 25922) eradication as an efficient and inexpensive process. Methods: Desired bacterial density and turbidity was achieved by spiking of 0.5 Mc Farland (1.5×108 cell/ml) and sterile soil slurry in 1 liter of the commercially bottled water. Results: The highest value of UVA solar irradiation measured at 13.30 p.m was 5510 μW/Cm2. Increase of bacterial density from 1000 to 1500 cell/ml led to an increase in disinfection lapse time, except in 2 mMol/l KPS. Spiking of 0.1 mMol/l of KPS was not effective; however, increase of KPS dosage from 0.1 mMol/l to 0.7, 1.5 and 2 mMol/l led to the enhancement of disinfection time from 4 h to 3 h and 1 h, respectively. For bacterial density of 1000 cell/ml, increasing KPS dosage up to 0.7 mMol/l had no improved effect; however, beyond this dosage the disinfection time decreased to 1 h. Without KPS and up to 150 NTU within 4 h exposure time, E. coli disinfection was completed. In 2 mMol/l KPS and 1000 and 1500 cell/ml, the 2 h contact time was sufficient up to 150 and 100 NTU, respectively; moreover, complete disinfection was not achieved at higher turbidity. Conclusion: Association of KPS with SODIS can lead to decreasing of water disinfection time. PMID:26576351

  18. Association between children's blood lead levels, lead service lines, and water disinfection, Washington, DC, 1998-2006.

    PubMed

    Brown, Mary Jean; Raymond, Jaime; Homa, David; Kennedy, Chinaro; Sinks, Thomas

    2011-01-01

    Evaluate the effect of changes in the water disinfection process, and presence of lead service lines (LSLs), on children's blood lead levels (BLLs) in Washington, DC. Three cross-sectional analyses examined the relationship of LSL and changes in water disinfectant with BLLs in children <6 years of age. The study population was derived from the DC Childhood Lead Poisoning Prevention Program blood lead surveillance system of children who were tested and whose blood lead test results were reported to the DC Health Department. The Washington, DC Water and Sewer Authority (WASA) provided information on LSLs. The final study population consisted of 63,854 children with validated addresses. Controlling for age of housing, LSL was an independent risk factor for BLLs ≥ 10 μg/dL, and ≥ 5 μg/dL even during time periods when water levels met the US Environmental Protection Agency (EPA) action level of 15 parts per billion (ppb). When chloramine alone was used to disinfect water, the risk for BLL in the highest quartile among children in homes with LSL was greater than when either chlorine or chloramine with orthophosphate was used. For children tested after LSLs in their houses were replaced, those with partially replaced LSL were >3 times as likely to have BLLs ≥ 10 μg/dL versus children who never had LSLs. LSLs were a risk factor for elevated BLLs even when WASA met the EPA water action level. Changes in water disinfection can enhance the effect of LSLs and increase lead exposure. Partially replacing LSLs may not decrease the risk of elevated BLLs associated with LSL exposure. Copyright © 2010 Elsevier Inc. All rights reserved.

  19. Evaluation of Surface Quality of Silicone Impression Materials after Disinfection with Ozone Water: An In vitro Study.

    PubMed

    Abinaya, K; Muthu Kumar, B; Ahila, S C

    2018-01-01

    To compare and evaluate the surface quality of silicone impression materials after ozone water disinfection. A total of 60 samples were prepared on a stainless steel die (American Dental Association specification no. 19 and International Standard of Organization - 4823). The samples were divided into four groups; each group contains 15 samples. Group A as control, Group B, C, and D disinfected with 2% glutaraldehyde, 5.25% sodium hypochlorite, and ozone water, respectively. The samples were made according to the manufacturer's instructions, and the samples were allowed to set in a thermostatically controlled water bath at 35°C ± 1°C and retrieved after 10 min. The surface qualities of the samples were measured in stereomicroscope with ×20 magnification. The data obtained were analyzed using Chi-square test, and the " P " value was calculated. The results showed that there were no differences in the surface quality among the Groups A, C, and D for addition silicone putty and light body and medium body impression materials than the Group B. This study concluded that ozone water disinfection showed least changes when compared to 5.25%sodium hypochloride and 2% glutaraldehyde disinfection for addition silicone putty , light body and medium body impression materials.

  20. IDENTIFICATION OF NEW DRINKING WATER DISINFECTION BY-PRODUCTS FORMED IN THE PRESENCE OF BROMIDE

    EPA Science Inventory

    Using a combination of mass spectrometry and infrared spectroscopy, disinfection by-products (DBPs) were identified in ozonated drinking water containing elevated bromide levels, and in ozonated water treated with secondary chlorine or chloramine. Only one brominated by-product-d...

  1. Type of disinfectant in drinking water and patterns of mortality in Massachusetts.

    PubMed Central

    Zierler, S; Danley, R A; Feingold, L

    1986-01-01

    Chlorination has been the major strategy for disinfection of drinking water in the United States. Concern about the potential health effects of the reaction by-products of chlorine has prompted use of alternative strategies. One such method is chloramination, a treatment process that does not appear to have carcinogenic by-products, but may have less potent biocidal activity than chlorination. We examined the patterns of mortality of residents in Massachusetts who died between 1969 and 1983 and lived in communities using drinking water that was disinfected either by chlorine or chloramine. Comparison of type of disinfectant among 51,645 cases of deaths due to selected cancer sites and 214,988 controls who died from cardiovascular, cerebrovascular, or pulmonary disease, or from lymphatic cancer showed small variation in the patterns of mortality. Bladder cancer was moderately associated with residence at death in a chlorinated community (mortality odds ratio = 1.7, 95% confidence interval = 1.3-2.2) in a logistic regression analysis using controls who died from lymphatic cancer. A slight excess of deaths from pneumonia and influenza was observed in communities whose residents drank chloraminated water compared to residents from chlorinated communities, as well as to all Massachusetts residents (standardized mortality ratio = 118, 95% confidence interval = 116-120 for chloraminated communities, and standardized mortality ratio = 98, 95% confidence interval = 95-100 for chlorinated communities). These results are intended to be preliminary and crude descriptions of the relationship under study.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:3816730

  2. The Next Generation of Disinfection By-Products

    EPA Science Inventory

    The disinfection of drinking water has been rightly hailed as a public health triumph of the 20th century. Millions of people worldwide receive quality drinking water every day from their public water systems. However, chemical disinfection has also produced an unintended health ...

  3. Biological Treatment of Water Disinfection Byproducts using Biotrickling Filter under Anaerobic Conditions

    EPA Science Inventory

    Presentation not available. Abstract provided. The chlorination of potable water leads to the formation of harmful disinfection byproducts (DBPs) such as trihalomethanes (THMs) and haloacetic acids (HAAs). Many of these compounds are volatile organic compounds (VOCs). DBPs may ...

  4. [Study on effect of 3 types of drinking water emergent disinfection models in flood/waterlog areas].

    PubMed

    Ban, Haiqun; Li, Jin; Li, Xinwu; Zhang, Liubo

    2010-09-01

    To establish 3 drinking water emergent disinfection processing models, separated medicate dispensing, specific duty medicate dispensing, and centralized filtering, in flood/waterlog areas, and compare the effects of these 3 models on the drinking water disinfection processing. From October to December, 2008, 18 villages were selected as the trial field in Yanglinwei town, Xiantao city, Hubei province, which were divided into three groups, separated medicate dispensing, specific duty medicate dispensing, and centralized filtering. Every 2 weeks, drinking water source water, yielding water of emergency central filtrate water equipment (ECFWE) and container water in the kitchen were sampled and microbe indices of the water sample, standard plate-count bacteria, total coliforms, thermotolerant coliform bacteria, Escherichia coli were measured. The microbe pollution of the water of these 3 water source groups are heavy, all failed. The eliminating rate of the standard plate-count bacteria of the drinking water emergent centralized processing equipment is 99.95%; those of the separate medicate dispensing, specific duty medicate dispensing and centralized filtering are 81.93%, 99.67%, and 98.28%, respectively. The passing rates of the microbe indice of the resident contained water are 13.33%, 70.00%, and 43.33%, respectively. The difference has statistical significance. The drinking water disinfection effects of the centralized filtering model and of the specific duty medicate dispensing model are better than that of the separated medicate dispensing model in the flood/waterlog areas.

  5. 40 CFR 141.543 - How is the disinfection benchmark calculated?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Enhanced Filtration and Disinfection-Systems Serving Fewer Than 10,000 People Disinfection Benchmark § 141.543 How is the disinfection... 40 Protection of Environment 22 2010-07-01 2010-07-01 false How is the disinfection benchmark...

  6. Assessing microbiological water quality in drinking water distribution systems with disinfectant residual using flow cytometry.

    PubMed

    Gillespie, Simon; Lipphaus, Patrick; Green, James; Parsons, Simon; Weir, Paul; Juskowiak, Kes; Jefferson, Bruce; Jarvis, Peter; Nocker, Andreas

    2014-11-15

    Flow cytometry (FCM) as a diagnostic tool for enumeration and characterization of microorganisms is rapidly gaining popularity and is increasingly applied in the water industry. In this study we applied the method to obtain a better understanding of total and intact cell concentrations in three different drinking water distribution systems (one using chlorine and two using chloramines as secondary disinfectants). Chloramine tended to result in lower proportions of intact cells than chlorine over a wider residual range, in agreement with existing knowledge that chloramine suppresses regrowth more efficiently. For chlorinated systems, free chlorine concentrations above 0.5 mg L(-1) were found to be associated with relatively low proportions of intact cells, whereas lower disinfectant levels could result in substantially higher percentages of intact cells. The threshold for chlorinated systems is in good agreement with guidelines from the World Health Organization. The fact that the vast majority of samples failing the regulatory coliform standard also showed elevated proportions of intact cells suggests that this parameter might be useful for evaluating risk of failure. Another interesting parameter for judging the microbiological status of water, the biological regrowth potential, greatly varied among different finished waters providing potential help for investment decisions. For its measurement, a simple method was introduced that can easily be performed by water utilities with FCM capability. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. IDENTIFICATION OF DRINKING WATER DISINFECTION BY-PRODUCTS FROM OZONE, CHLORINE DIOXIDE, CHLORAMINE, AND CHLORINE

    EPA Science Inventory

    Many drinking water treatment plants are currently using alternative disinfectants to treat drinking water, with ozone, chlorine dioxide, and chloramine being the most popular. However, compared to chlorine, which has been much more widely studied, there is little information abo...

  8. OXIDATIVE DNA DAMAGE AND REPAIR IN RATS TREATED WITH POTASSIUM BROMATE AND A MIXTUE OF DRINKING WATER DISINFECTION BY-PRODUCTS

    EPA Science Inventory

    Oxidative DNA Damage and Repair in Rats Treated with Potassium Bromate and a Mixture of Drinking Water Disinfection By-Products

    Public drinking water treated with chemical disint'ectants contains a complex mixture of disinfection by-products (D BPs). There is a need for m...

  9. OCCURRENCE, GENOTOXICITY, AND CARCINOGENICITY OF EMERGING DISINFECTION BY-PRODUCTS IN DRINKING WATER: A REVIEW AND ROADMAP FOR RESEARCH

    EPA Science Inventory

    Disinfection by-products (DBPs) are formed when disinfectants (chlorine, ozone, chlorine dioxide, or chloramines) react with naturally occurring organic matter, anthropogenic contaminants, bromide, and iodide during the production of drinking water. Here we review 30 years of re...

  10. [Study on pipe material's influence on chlorine dioxide drinking water disinfection].

    PubMed

    He, Tao; Yue, Yinling; Ling, Bo; Zhang, Lan

    2010-09-01

    To study the pipe material's influence on chlorine dioxide drinking water disinfection. 0.8 mg/L chlorine dioxide solution was injected into 5 kinds of pipes respectively, PPR, PVC-U, Steel with Zinc coating, copper and PE pipes. Dipped free from light for 48 hours and the concentrations of chlorine dioxide, chlorite and chlorate were tested from samples taken from each kind of pipe at 1, 2, 3, 4, 5, 6, 12, 24 and 48 hours respectively. Chlorine dioxides decay rates in the water dipping the pipes increase as the dipping time increases and the decay of chlorine dioxide mainly occurs within 6 hours after the dipping. But for different pipe, the influence of decay differs. The consumption of chlorine dioxide of the metal pipes is more than that of the plastic pipes. And with 2 hours after the dipping experiment begins, the concentrations of the chlorite of the copper pipe and of the steel with zinc coating pipe increase quickly and reach the maximum concentration. But then the chlorite concentration decreases greatly. After dipped 24 hours, the chlorite in the water in the pipe can not be detected. For other plastic piples, all the chlorite concentrations in the dipping water increase as the dipping time increase. Compared with the start of the dipping experiment, the chlorate concentration in the dipping water of each pipe has no obvious change. The material of the water transportation pipe does have influence on chlorine dioxide drinking water disinfection.

  11. Combined effects of coagulation and adsorption on ultrafiltration membrane fouling control and subsequent disinfection in drinking water treatment.

    PubMed

    Xing, Jiajian; Liang, Heng; Cheng, Xiaoxiang; Yang, Haiyan; Xu, Daliang; Gan, Zhendong; Luo, Xinsheng; Zhu, Xuewu; Li, Guibai

    2018-06-02

    This study investigated the combined effects of coagulation and powdered activated carbon (PAC) adsorption on ultrafiltration (UF) membrane fouling control and subsequent disinfection efficiency through filtration performance, dissolved organic carbon (DOC) removal, fluorescence excitation-emission matrix (EEM) spectroscopy, and disinfectant curve. The fouling behavior of UF membrane was comprehensively analyzed especially in terms of pollutant removal and fouling reversibility to understand the mechanism of fouling accumulation and disinfectant dose reduction. Pre-coagulation with or without adsorption both achieved remarkable effect of fouling mitigation and disinfection dose reduction. The two pretreatments were effective in total fouling control and pre-coagulation combined with PAC adsorption even decreased hydraulically irreversible fouling notably. Besides, pre-coagulation decreased residual disinfectant decline due to the removal of hydrophobic components of natural organic matters (NOM). Pre-coagulation combined with adsorption had a synergistic effect on further disinfectant decline rate reduction and decreased total disinfectant consumption due to additional removal of hydrophilic NOM by PAC adsorption. The disinfectant demand was further reduced after membrane. These results show that membrane fouling and disinfectant dose can be reduced in UF coupled with pretreatment, which could lead to the avoidance of excessive operation cost disinfectant dose for drinking water supply.

  12. The effect of inorganic precursors on disinfection byproduct formation during UV-chlorine/chloramine drinking water treatment.

    PubMed

    Lyon, Bonnie A; Dotson, Aaron D; Linden, Karl G; Weinberg, Howard S

    2012-10-01

    Ultraviolet (UV) disinfection is being increasingly used in drinking water treatment. It is important to understand how its application to different types of water may influence finished water quality, particularly as anthropogenic activity continues to impact the quality of source waters. The objective of this study was to evaluate the effect of inorganic precursors on the formation of regulated and unregulated disinfection byproducts (DBPs) during UV irradiation of surface waters when combined with chlorination or chloramination. Samples were collected from three drinking water utilities supplied by source waters with varying organic and inorganic precursor content. The filtered samples were treated in the laboratory with a range of UV doses delivered from low pressure (LP, UV output at 253.7 nm) and medium pressure (MP, polychromatic UV output 200-400 nm) mercury lamps followed by chlorination or chloramination, in the presence and absence of additional bromide and nitrate. The regulated trihalomethanes and haloacetic acids were not affected by UV pretreatment at disinfection doses (40-186 mJ/cm²). With higher doses (1000 mJ/cm²), trihalomethane formation was increased 30-40%. While most effects on DBPs were only observed with doses much higher than typically used for UV disinfection, there were some effects on unregulated DBPs at lower doses. In nitrate-spiked samples (1-10 mg N/L), chloropicrin formation doubled and increased three- to six-fold with 40 mJ/cm² MP UV followed by chloramination and chlorination, respectively. Bromopicrin formation was increased in samples containing bromide (0.5-1 mg/L) and nitrate (1-10 mg N/L) when pretreated with LP or MP UV (30-60% with 40 mJ/cm² LP UV and four- to ten-fold increase with 40 mJ/cm² MP UV, after subsequent chlorination). The formation of cyanogen chloride doubled and increased three-fold with MP UV doses of 186 and 1000 mJ/cm², respectively, when followed by chloramination in nitrate-spiked samples but

  13. Impact of wastewater infrastructure upgrades on the urban water cycle: Reduction in halogenated reaction byproducts following conversion from chlorine gas to ultraviolet light disinfection

    USGS Publications Warehouse

    Barber, Larry B.; Hladik, Michelle; Vajda, Alan M.; Fitzgerald, Kevin C.; Douville, Chris

    2015-01-01

    The municipal wastewater treatment facility (WWTF) infrastructure of the United States is being upgraded to expand capacity and improve treatment, which provides opportunities to assess the impact of full-scale operational changes on water quality. Many WWTFs disinfect their effluent prior to discharge using chlorine gas, which reacts with natural and synthetic organic matter to form halogenated disinfection byproducts (HDBPs). Because HDBPs are ubiquitous in chlorine-disinfected drinking water and have adverse human health implications, their concentrations are regulated in potable water supplies. Less is known about the formation and occurrence of HDBPs in disinfected WWTF effluents that are discharged to surface waters and become part of the de facto wastewater reuse cycle. This study investigated HDBPs in the urban water cycle from the stream source of the chlorinated municipal tap water that comprises the WWTF inflow, to the final WWTF effluent disinfection process before discharge back to the stream. The impact of conversion from chlorine-gas to low-pressure ultraviolet light (UV) disinfection at a full-scale (68,000 m3 d−1 design flow) WWTF on HDBP concentrations in the final effluent was assessed, as was transport and attenuation in the receiving stream. Nutrients and trace elements (boron, copper, and uranium) were used to characterize the different urban source waters, and indicated that the pre-upgrade and post-upgrade water chemistry was similar and insensitive to the disinfection process. Chlorinated tap water during the pre-upgrade and post-upgrade samplings contained 11 (mean total concentration = 2.7 μg L−1; n=5) and 10 HDBPs (mean total concentration = 4.5 μg L−1), respectively. Under chlorine-gas disinfection conditions 13 HDBPs (mean total concentration = 1.4 μg L−1) were detected in the WWTF effluent, whereas under UV disinfection conditions, only one HDBP was detected. The chlorinated WWTF effluent had greater relative

  14. Impact of wastewater infrastructure upgrades on the urban water cycle: Reduction in halogenated reaction byproducts following conversion from chlorine gas to ultraviolet light disinfection.

    PubMed

    Barber, Larry B; Hladik, Michelle L; Vajda, Alan M; Fitzgerald, Kevin C; Douville, Chris

    2015-10-01

    The municipal wastewater treatment facility (WWTF) infrastructure of the United States is being upgraded to expand capacity and improve treatment, which provides opportunities to assess the impact of full-scale operational changes on water quality. Many WWTFs disinfect their effluent prior to discharge using chlorine gas, which reacts with natural and synthetic organic matter to form halogenated disinfection byproducts (HDBPs). Because HDBPs are ubiquitous in chlorine-disinfected drinking water and have adverse human health implications, their concentrations are regulated in potable water supplies. Less is known about the formation and occurrence of HDBPs in disinfected WWTF effluents that are discharged to surface waters and become part of the de facto wastewater reuse cycle. This study investigated HDBPs in the urban water cycle from the stream source of the chlorinated municipal tap water that comprises the WWTF inflow, to the final WWTF effluent disinfection process before discharge back to the stream. The impact of conversion from chlorine-gas to low-pressure ultraviolet light (UV) disinfection at a full-scale (68,000 m(3) d(-1) design flow) WWTF on HDBP concentrations in the final effluent was assessed, as was transport and attenuation in the receiving stream. Nutrients and trace elements (boron, copper, and uranium) were used to characterize the different urban source waters, and indicated that the pre-upgrade and post-upgrade water chemistry was similar and insensitive to the disinfection process. Chlorinated tap water during the pre-upgrade and post-upgrade samplings contained 11 (mean total concentration=2.7 μg L(-1); n=5) and 10 HDBPs (mean total concentration=4.5 μg L(-1)), respectively. Under chlorine-gas disinfection conditions 13 HDBPs (mean total concentration=1.4 μg L(-1)) were detected in the WWTF effluent, whereas under UV disinfection conditions, only one HDBP was detected. The chlorinated WWTF effluent had greater relative proportions of

  15. Chemistry, Toxicity and Health Risk Assessment of Drinking Water Disinfection ByProducts

    EPA Science Inventory

    Disinfection byproducts (DBPs) are formed by the reaction of oxidizing chemicals (such as chlorine, ozone and chloramines) used to control waterborne pathogens with natural organic material and other substances in water. DBP mixture composition varies as a function of geographic ...

  16. 40 CFR 141.53 - Maximum contaminant level goals for disinfection byproducts.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... disinfection byproducts. 141.53 Section 141.53 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Maximum Contaminant Level... disinfection byproducts. MCLGs for the following disinfection byproducts are as indicated: Disinfection...

  17. Pilot Study for UVA-LED Disinfection of Escherichia coli in Water for Space and Earth Applications

    NASA Technical Reports Server (NTRS)

    Ragolta, Carolina

    2010-01-01

    To test the efficacy of UVA-LED disinfection, a solution of Escherichia coli was pumped through a modified drip flow reactor at a flow rate of 1 ml/min. The experiment was conducted in a controlled environment chamber to ensure that temperature did not cause disinfection. The reactor featured three wells with different treatments: UVA-LED irradiation, UVA-LEDs with Ti02, and UVA-LEDs with nanosilver. Samples from each well were taken throughout a 340 hour period, inactivated, assayed, and analyzed for E. coli disinfection. Results of the duplicate experiments indicated longer exposure times are needed for UVA-LED disinfection of E. coli in water. Further research would consider a longer sampling period and different test conditions, such as increased contact area and various flow rates.

  18. DEVELOPMENT OF A RESEARCH STRATEGY FOR INTEGRATED TECHNOLOGY-BASED TOXICOLOGICAL AND CHEMICAL EVALUATION OF COMPLEX MIXTURES OF DRINKING WATER DISINFECTION BYPRODUCTS

    EPA Science Inventory

    Chemical disinfection of water is a major public health triumph of the 20th century. Dramatic decreases in both morbidity and mortality of waterborne diseases are a direct result of water disinfection. With these important public health benefits comes low-level, chronic exposure ...

  19. REPRODUCTIVE AND DEVELOPMENTAL TOXICITY ASSOCIATED WITH DISINFECTION BY-PRODUCTS OF DRINKING WATER

    EPA Science Inventory

    Over the past decade many toxicologic studies have addressed the potential for disinfection byproducts of drinking water to elicit alterations on the reproductive system and fetal development.
    The types and designs of these studies vary considerably, but in general they can ...

  20. Do You Know What's in Your Drinking Water? Uncovering New Disinfection By-Products

    EPA Science Inventory

    Slide presentation on drinking water disinfection by-products. There is no abstract for this product. If further information is requested, please refer to the bibliographic citation and contact the person listed under Contact field.

  1. Organic chloramines in chlorine-based disinfected water systems: A critical review.

    PubMed

    How, Zuo Tong; Kristiana, Ina; Busetti, Francesco; Linge, Kathryn L; Joll, Cynthia A

    2017-08-01

    This paper is a critical review of current knowledge of organic chloramines in water systems, including their formation, stability, toxicity, analytical methods for detection, and their impact on drinking water treatment and quality. The term organic chloramines may refer to any halogenated organic compounds measured as part of combined chlorine (the difference between the measured free and total chlorine concentrations), and may include N-chloramines, N-chloramino acids, N-chloraldimines and N-chloramides. Organic chloramines can form when dissolved organic nitrogen or dissolved organic carbon react with either free chlorine or inorganic chloramines. They are potentially harmful to humans and may exist as an intermediate for other disinfection by-products. However, little information is available on the formation or occurrence of organic chloramines in water due to a number of challenges. One of the biggest challenges for the identification and quantification of organic chloramines in water systems is the lack of appropriate analytical methods. In addition, many of the organic chloramines that form during disinfection are unstable, which results in difficulties in sampling and detection. To date research has focussed on the study of organic monochloramines. However, given that breakpoint chlorination is commonly undertaken in water treatment systems, the formation of organic dichloramines should also be considered. Organic chloramines can be formed from many different precursors and pathways. Therefore, studying the occurrence of their precursors in water systems would enable better prediction and management of their formation. Copyright © 2017. Published by Elsevier B.V.

  2. Effect of Disinfectants on Glucose Monitors

    PubMed Central

    Mahoney, John J; Lim, Christine G

    2012-01-01

    Background Monitoring blood glucose levels is an integral part of routine diabetes management. To minimize the risk of transmission of bloodborne pathogens during monitoring, the Centers for Disease Control and Prevention (CDC) recommends that glucose meters be disinfected after each use whenever they are used to test multiple patients. The objective of this study is to assess the compatibility of some common disinfectants with certain blood glucose meter systems. Methods We tested six disinfectants for adverse impact on meter performance or the exterior meter surfaces. The disinfectants tested were 0.525% sodium hypochlorite, 20% 2-propanol and 10% ethanol, 17.2% isopropanol, 55% isopropanol, 70% isopropanol, and hydrogen peroxide. To assess meter performance, we tested OneTouch® Ultra® blood glucose monitoring systems with control solution before and after application of either water or disinfectant. To assess the effect on exterior meter surfaces, we performed a soaking test to simulate long-term exposure to disinfectant. Results Paired t-test results showed that the control solution data associated with disinfectant and with water application were not significantly different for each meter type. However, most of the meter types were adversely affected by hydrogen peroxide and/or by the higher concentrations of alcohol-based disinfectants. Conclusions Although none of the six disinfectants affected meter performance, hydrogen peroxide and isopropanol >20% adversely affected the exterior surfaces of the tested meters. When complying with CDC instructions for meter disinfection, users should use caution and choose disinfectants that have been validated by the meter manufacturer. PMID:22401326

  3. Effect of disinfectants on glucose monitors.

    PubMed

    Mahoney, John J; Lim, Christine G

    2012-01-01

    Monitoring blood glucose levels is an integral part of routine diabetes management. To minimize the risk of transmission of bloodborne pathogens during monitoring, the Centers for Disease Control and Prevention (CDC) recommends that glucose meters be disinfected after each use whenever they are used to test multiple patients. The objective of this study is to assess the compatibility of some common disinfectants with certain blood glucose meter systems. We tested six disinfectants for adverse impact on meter performance or the exterior meter surfaces. The disinfectants tested were 0.525% sodium hypochlorite, 20% 2-propanol and 10% ethanol, 17.2% isopropanol, 55% isopropanol, 70% isopropanol, and hydrogen peroxide. To assess meter performance, we tested OneTouch® Ultra® blood glucose monitoring systems with control solution before and after application of either water or disinfectant. To assess the effect on exterior meter surfaces, we performed a soaking test to simulate long-term exposure to disinfectant. Paired t-test results showed that the control solution data associated with disinfectant and with water application were not significantly different for each meter type. However, most of the meter types were adversely affected by hydrogen peroxide and/or by the higher concentrations of alcohol-based disinfectants. Although none of the six disinfectants affected meter performance, hydrogen peroxide and isopropanol >20% adversely affected the exterior surfaces of the tested meters. When complying with CDC instructions for meter disinfection, users should use caution and choose disinfectants that have been validated by the meter manufacturer. © 2012 Diabetes Technology Society.

  4. Bromination of Marine Dissolved Organic Matter following Full Scale Electrochemical Ballast Water Disinfection.

    PubMed

    Gonsior, Michael; Mitchelmore, Carys; Heyes, Andrew; Harir, Mourad; Richardson, Susan D; Petty, William Tyler; Wright, David A; Schmitt-Kopplin, Philippe

    2015-08-04

    An extensively diverse array of brominated disinfection byproducts (DBPs) were generated following electrochemical disinfection of natural coastal/estuarine water, which is one of the main treatment methods currently under consideration for ballast water treatment. Ultra-high-resolution mass spectrometry revealed 462 distinct brominated DBPs at a relative abundance in the mass spectra of more than 1%. A brominated DBP with a relative abundance of almost 22% was identified as 2,2,4-tribromo-5-hydroxy-4-cyclopentene-1,3-dione, which is an analogue to several previously described 2,2,4-trihalo-5-hydroxy-4-cyclopentene-1,3-diones in drinking water. Several other brominated molecular formulas matched those of other known brominated DBPs, such as dibromomethane, which could be generated by decarboxylation of dibromoacetic acid during ionization, dibromophenol, dibromopropanoic acid, dibromobutanoic acid, bromohydroxybenzoic acid, bromophenylacetic acid, bromooxopentenoic acid, and dibromopentenedioic acid. Via comparison to previously described chlorine-containing analogues, bromophenylacetic acid, dibromooxopentenoic acid, and dibromopentenedioic acid were also identified. A novel compound at a 4% relative abundance was identified as tribromoethenesulfonate. This compound has not been previously described as a DBP, and its core structure of tribromoethene has been demonstrated to show toxicological implications. Here we show that electrochemical disinfection, suggested as a candidate for successful ballast water treatment, caused considerable production of some previously characterized DBPs in addition to novel brominated DBPs, although several hundred compounds remain structurally uncharacterized. Our results clearly demonstrate that electrochemical and potentially direct chlorination of ballast water in estuarine and marine systems should be approached with caution and the concentrations, fate, and toxicity of DBP need to be further characterized.

  5. Microbiological effectiveness and cost of boiling to disinfect drinking water in rural Vietnam.

    PubMed

    Clasen, Thomas F; Thao, Do Hoang; Boisson, Sophie; Shipin, Oleg

    2008-06-15

    Despite certain shortcomings, boiling is still the most common means of treating water in the home and the benchmark against which alternative household-based disinfection and filtration methods must be measured. We assessed the microbiological effectiveness and cost of boiling among a vulnerable population relying on unimproved water sources and commonly practicing boiling as a means of disinfecting water. In a 12 week study among 50 households from a rural community in Vietnam, boiling was associated with a 97% reduction in geometric mean thermotolerant coliforms (TTCs) (p < 0.001). Despite high levels of faecal contamination in source water, 37% of stored water samples from self-reported boilers met the WHO standard for safe drinking water (0 TTC/100 mL), and 38.3% fell within the low risk category (1--10 TTC/100 mL). Nevertheless, 60.5% of stored drinking water samples were positive for TTC, with 22.2% falling into the medium risk category (11--100 TTC/100 mL). The estimated cost of wood used to boil water was US$ 0.272 per month for wood collectors and US$ 1.68 per month for wood purchasers, representing approximately 0.48% to 1.04%, respectively, of the average monthly income of participating households.

  6. Culture-dependent enumeration methods failed to simultaneously detect disinfectant-injured and genetically modified Escherichia coli in drinking water.

    PubMed

    Li, Jing; Liu, Lu; Yang, Dong; Liu, Wei-Li; Shen, Zhi-Qiang; Qu, Hong-Mei; Qiu, Zhi-Gang; Hou, Ai-Ming; Wang, Da-Ning; Ding, Chen-Shi; Li, Jun-Wen; Guo, Jian-Hua; Jin, Min

    2017-05-24

    Underestimation of Escherichia coli in drinking water, an indicator microorganism of sanitary risk, may result in potential risks of waterborne diseases. However, the detection of disinfectant-injured or genetically modified (GM) E. coli has been largely overlooked so far. To evaluate the accuracy of culture-dependent enumeration with regard to disinfectant-injured and GM E. coli, chlorine- or ozone-injured wild-type (WT) and GM E. coli were prepared and characterized. Then, water samples contaminated with these E. coli strains were assayed by four widely used methods, including lactose tryptose broth-based multiple-tube fermentation (MTF), m-endo-based membrane filtration method (MFM), an enzyme substrate test (EST) known as Colilert, and Petrifilm-based testing slip method (TSM). It was found that MTF was the most effective method to detect disinfectant-injured WT E. coli (with 76.9% trials detecting all these bacteria), while this method could not effectively detect GM E. coli (with uninjured bacteria undetectable and a maximal detection rate of 21.5% for the injured). The EST was the only method which enabled considerable enumeration of uninjured GM E. coli, with a detection rate of over 93%. However, the detection rate declined to lower than 45.4% once the GM E. coli was injured by disinfectants. The MFM was invalid for both disinfectant-injured and GM E. coli. This is the first study to report the failure of these commonly used enumeration methods to simultaneously detect disinfectant-injured and GM E. coli. Thus, it highlights the urgent requirement for the development of a more accurate and versatile enumeration method which allows the detection of disinfectant-injured and GM E. coli on the assessment of microbial quality of drinking water.

  7. Point-of-use water disinfection using ultraviolet and visible light-emitting diodes.

    PubMed

    Lui, Gough Yumu; Roser, David; Corkish, Richard; Ashbolt, Nicholas J; Stuetz, Richard

    2016-05-15

    Improvements in point-of-use (POU) drinking water disinfection technologies for remote and regional communities are urgently needed. Conceptually, UV-C light-emitting diodes (LEDs) overcome many drawbacks of low-pressure mercury tube based UV devices, and UV-A or visible light LEDs also show potential. To realistically evaluate the promise of LED disinfection, our study assessed the performance of a model 1.3 L reactor, similar in size to solar disinfection bottles. In all, 12 different commercial or semi-commercial LED arrays (270-740 nm) were compared for their ability to inactivate Escherichia coli K12 ATCC W3110 and Enterococcus faecalis ATCC 19433 over 6h. Five log10 and greater reductions were consistently achieved using the 270, 365, 385 and 405 nm arrays. The output of the 310 nm array was insufficient for useful disinfection while 430 and 455 nm performance was marginal (≈ 4.2 and 2.3-log10s E. coli and E. faecalis over the 6h). No significant disinfection was observed with the 525, 590, 623, 660 and 740 nm arrays. Delays in log-phase inactivation of E. coli were observed, particularly with UV-A wavelengths. The radiation doses required for >3-log10 reduction of E. coli and E. faecalis differed by 10 fold at 270 nm but only 1.5-2.5 fold at 365-455 nm. Action spectra, consistent with the literature, were observed with both indicators. The design process revealed cost and technical constraints pertaining to LED electrical efficiency, availability and lifetime. We concluded that POU LED disinfection using existing LED technology is already technically possible. UV-C LEDs offer speed and energy demand advantages, while UV-A/violet units are safer. Both approaches still require further costing and engineering development. Our study provides data needed for such work. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. [Improvement of effectivity of photo disinfection of water from bacterial contaminants in the presence of heterogeneous sensitizers based on phthalocyanines grafted to aminopropyl silicagel].

    PubMed

    Maksimkina, T N; Artemova, T Z; Kuznetsova, N A; Sinitsyna, O O; Gipp, E K; Zagaĭnova, A V; Butorina, N N; Iuzhakova, O A; Krasniak, A V

    2012-01-01

    The possibility of using 12 heterogeneous sensitizers (HS) based on phthalocyanines covalently grafted to aminopropyl silicagel for disinfection of water from bacteria has been studied. For reliable water quality control the technique of performing bacteriological analysis in the presence of HS beads in the sample has been elaborated. The conditions increasing the efficiency of photo disinfection in the presence of HS were studied. Algorithm for estimation of photo disinfectant effect of HS against bacteria was substantiated. Obtained data confirm the perspective of further studies on the substantiation of the possibility of the application of HS for water disinfection.

  9. Biological efficacy and toxic effect of emergency water disinfection process based on advanced oxidation technology.

    PubMed

    Tian, Yiping; Yuan, Xiaoli; Xu, Shujing; Li, Rihong; Zhou, Xinying; Zhang, Zhitao

    2015-12-01

    An innovative and removable water treatment system consisted of strong electric field discharge and hydrodynamic cavitation based on advanced oxidation technologies was developed for reactive free radicals producing and waterborne pathogens eliminating in the present study. The biological efficacy and toxic effects of this advanced oxidation system were evaluated during water disinfection treatments. Bench tests were carried out with synthetic microbial-contaminated water, as well as source water in rainy season from a reservoir of Dalian city (Liaoning Province, China). Results showed that high inactivation efficiency of Escherichia coli (>5 log) could be obtained for synthetic contaminated water at a low concentration (0.5-0.7 mg L(-1)) of total oxidants in 3-10 s. The numbers of wild total bacteria (108 × 10(3) CFU mL(-1)) and total coliforms (260 × 10(2) MPN 100 mL(-1)) in source water greatly reduced to 50 and 0 CFU mL(-1) respectively after treated by the advanced oxidation system, which meet the microbiological standards of drinking water, and especially that the inactivation efficiency of total coliforms could reach 100%. Meanwhile, source water qualities were greatly improved during the disinfection processes. The values of UV254 in particular were significantly reduced (60-80%) by reactive free radicals. Moreover, the concentrations of possible disinfection by-products (formaldehyde and bromide) in treated water were lower than detection limits, indicating that there was no harmful effect on water after the treatments. These investigations are helpful for the ecotoxicological studies of advanced oxidation system in the treatments of chemical polluted water or waste water. The findings of this work suggest that the developed water treatment system is ideal in the acute phases of emergencies, which also could offer additional advantages over a wide range of applications in water pollution control.

  10. Silver nanowire-carbon fiber cloth nanocomposites synthesized by UV curing adhesive for electrochemical point-of-use water disinfection.

    PubMed

    Hong, Xuesen; Wen, Junjie; Xiong, Xuhua; Hu, Yongyou

    2016-07-01

    Novel silver nanowire (AgNW) - carbon fiber cloth (CC) nanocomposites were synthesized by a rapid and facile method. Acting as filter in an electrical gravity filtration device, the AgNW-CC nanocomposites were applied to electrochemical point-of-use water disinfection. AgNW-CC nanocomposites were characterized by FESEM, XRD, and FTIR. Their disinfection performance toward Escherichia coli and bacteriophage MS2 was evaluated by inhibition zone tests, optical density growth curve tests, and flow tests. The results showed that complex 3D AgNW networks with controllable silver release (<100 ppb) were fabricated on CC by using UV curing adhesive. AgNW-CC nanocomposites exhibited excellent intrinsic antibacterial activities against E. coli. The concentration of AgNWs and UV adhesive controlled the released silver and hence led to the change in antibacterial activity. The external electric field significantly enhanced the disinfection efficiency of AgNW-CC nanocomposites. Over 99.999% removal of E. coli and MS2 could be achieved. More complex AgNW networks contributed to higher disinfection efficiency under 10 V and 10(6) CFU (PFU) mL(-1) of microorganism. UV adhesive could keep the disinfection performance from being affected by flow rate. The convenient synthesis and outstanding disinfection performance offer AgNW-CC nanocomposites opportunities in the application of electrochemical point-of-use drinking water disinfection. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Pulsed-Plasma Disinfection of Water Containing Escherichia coli

    NASA Astrophysics Data System (ADS)

    Satoh, Kohki; MacGregor, Scott J.; Anderson, John G.; Woolsey, Gerry A.; Fouracre, R. Anthony

    2007-03-01

    The disinfection of water containing the microorganism, Escherichia coli (E. coli) by exposure to a pulsed-discharge plasma generated above the water using a multineedle electrode (plasma-exposure treatment), and by sparging the off-gas of the pulsed plasma into the water (off-gas-sparging treatment), is performed in the ambient gases of air, oxygen, and nitrogen. For the off-gas-sparging treatment, bactericidal action is observed only when oxygen is used as the ambient gas, and ozone is found to generate the bactericidal action. For the plasma-exposure treatment, the density of E. coli bacteria decreases exponentially with plasma-exposure time for all the ambient gases. It may be concluded that the main contributors to E. coli inactivation are particle species produced by the pulsed plasma. For the ambient gases of air and nitrogen, the influence of acidification of the water in the system, as a result of pulsed-plasma exposure, may also contribute to the decay of E. coli density.

  12. ASSESSMENT OF HUMAN DIETARY INGESTION EXPOSURES TO WATER DISINFECTION BYPRODUCTS VIA FOOD

    EPA Science Inventory

    The overall objective of this research is to estimate the magnitude of exposure to disinfection byproducts (DBPs) in drinking water via their ingestion after uptake into food during cooking. It has been shown in our laboratory that foods can become contaminated with chemicals in ...

  13. Disinfection by-products (DBPs) in drinking water and predictive models for their occurrence: a review.

    PubMed

    Sadiq, Rehan; Rodriguez, Manuel J

    2004-04-05

    Disinfection for drinking water reduces the risk of pathogenic infection but may pose chemical threat to human health due to disinfection residues and their by-products (DBPs) when the organic and inorganic precursors are present in water. More than 250 DBPs have been identified, but the behavioural profile of only approximately 20 DBPs are adequately known. In the last 2 decades, many modelling attempts have been made to predict the occurrence of DBPs in drinking water. Models have been developed based on data generated in laboratory-scaled and field-scaled investigations. The objective of this paper is to review DBPs predictive models, identify their advantages and limitations, and examine their potential applications as decision-making tools for water treatment analysis, epidemiological studies and regulatory concerns. The paper concludes with a discussion about the future research needs in this area.

  14. Human cell toxicogenomic analysis of bromoacetic acid: a regulated drinking water disinfection by-product.

    PubMed

    Muellner, Mark G; Attene-Ramos, Matias S; Hudson, Matthew E; Wagner, Elizabeth D; Plewa, Michael J

    2010-04-01

    The disinfection of drinking water is a major achievement in protecting the public health. However, current disinfection methods also generate disinfection by-products (DBPs). Many DBPs are cytotoxic, genotoxic, teratogenic, and carcinogenic and represent an important class of environmentally hazardous chemicals that may carry long-term human health implications. The objective of this research was to integrate in vitro toxicology with focused toxicogenomic analysis of the regulated DBP, bromoacetic acid (BAA) and to evaluate modulation of gene expression involved in DNA damage/repair and toxic responses, with nontransformed human cells. We generated transcriptome profiles for 168 genes with 30 min and 4 hr exposure times that did not induce acute cytotoxicity. Using qRT-PCR gene arrays, the levels of 25 transcripts were modulated to a statistically significant degree in response to a 30 min treatment with BAA (16 transcripts upregulated and nine downregulated). The largest changes were observed for RAD9A and BRCA1. The majority of the altered transcript profiles are genes involved in DNA repair, especially the repair of double strand DNA breaks, and in cell cycle regulation. With 4 hr of treatment the expression of 28 genes was modulated (12 upregulated and 16 downregulated); the largest fold changes were in HMOX1 and FMO1. This work represents the first nontransformed human cell toxicogenomic study with a regulated drinking water disinfection by-product. These data implicate double strand DNA breaks as a feature of BAA exposure. Future toxicogenomic studies of DBPs will further strengthen our limited knowledge in this growing area of drinking water research. Copyright 2009 Wiley-Liss, Inc.

  15. A Toxicological Perspective on Disinfection ByProducts

    EPA Science Inventory

    Disinfection of water is essential for reduction of microbes harmful to human health and chemical disinfection is considered one of the major public health triumphs of the 20th Century. An unintended consequence of disinfection with oxidizing chemicals is formation of disinfectio...

  16. Progressive Increase in Disinfection By-products and Mutagenicity from Source to Tap to Swimming Pool and Spa Water: Impact of Human Use

    EPA Science Inventory

    Pools and spas are enjoyed throughout the world for exercise and relaxation. However, there are no previous studies on mutagenicity of disinfected spa (hot tub) waters or comprehensive identification of disinfection byproducts (DBPs) formed in spas. Using 28 water samples from ...

  17. Socioeconomic status and exposure to disinfection by-products in drinking water in Spain.

    PubMed

    Castaño-Vinyals, Gemma; Cantor, Kenneth P; Villanueva, Cristina M; Tardon, Adonina; Garcia-Closas, Reina; Serra, Consol; Carrato, Alfredo; Malats, Núria; Rothman, Nathaniel; Silverman, Debra; Kogevinas, Manolis

    2011-03-16

    Disinfection by-products in drinking water are chemical contaminants that have been associated with cancer and other adverse effects. Exposure occurs from consumption of tap water, inhalation and dermal absorption. We determined the relationship between socioeconomic status and exposure to disinfection by-products in 1271 controls from a multicentric bladder cancer case-control study in Spain. Information on lifetime drinking water sources, swimming pool attendance, showering-bathing practices, and socioeconomic status (education, income) was collected through personal interviews. The most highly educated subjects consumed less tap water (57%) and more bottled water (33%) than illiterate subjects (69% and 17% respectively, p-value = 0.003). These differences became wider in recent time periods. The time spent bathing or showering was positively correlated with attained educational level (p < 0.001). Swimming pool attendance was more frequent among highly educated subjects compared to the illiterate (odds ratio = 3.4; 95% confidence interval 1.6-7.3). The most highly educated subjects were less exposed to chlorination by-products through ingestion but more exposed through dermal contact and inhalation in pools and showers/baths. Health risk perceptions and economic capacity may affect patterns of water consumption that can result in differences in exposure to water contaminants.

  18. USING MEMBRANES TO CONCENTRATE DISINFECTION BYPRODUCTS FOR SUBSEQUENT HEALTH EFFECTS STUDIES

    EPA Science Inventory

    Chemical disinfection of water is a major public health advance that has decreased dramatically water-borne disease. Disinfecting agents react with naturally occurring organic and inorganic matter in water to produce a wide variety of disinfection byproducts (DBPs). Although mo...

  19. Long-term effects of hospital water network disinfection on Legionella and other waterborne bacteria in an Italian university hospital.

    PubMed

    Casini, Beatrice; Buzzigoli, Andrea; Cristina, Maria Luisa; Spagnolo, Anna Maria; Del Giudice, Pietro; Brusaferro, Silvio; Poscia, Andrea; Moscato, Umberto; Valentini, Paola; Baggiani, Angelo; Privitera, Gaetano

    2014-03-01

    Legionella control still remains a critical issue in healthcare settings where the preferred approach to health risk assessment and management is to develop a water safety plan. We report the experience of a university hospital, where a water safety plan has been applied since 2002, and the results obtained with the application of different methods for disinfecting hot water distribution systems in order to provide guidance for the management of water risk. The disinfection procedures included continuous chlorination with chlorine dioxide (0.4-0.6 mg/L in recirculation loops) reinforced by endpoint filtration in critical areas and a water treatment based on monochloramine (2-3 mg/L). Real-time polymerase chain reaction and a new immunoseparation and adenosine triphosphate bioluminescence analysis were applied in environmental monitoring. After 9 years, the integrated disinfection-filtration strategy significantly reduced positive sites by 55% and the mean count by 78% (P < .05); however, the high costs and the occurrence of a chlorine-tolerant clone belonging to Legionella pneumophila ST269 prompted us to test a new disinfectant. The shift to monochloramine allowed us to eliminate planktonic Legionella and did not require additional endpoint filtration; however, nontuberculous mycobacteria were isolated more frequently as long as the monochloramine concentration was 2 mg/L; their cultivability was never regained by increasing the concentration up to 3 mg/L. Any disinfection method needs to be adjusted/fine-tuned in individual hospitals in order to maintain satisfactory results over time, and only a locally adapted evidence-based approach allows assessment of the efficacy and disadvantages of the control measures.

  20. 17β-estradiol as precursors of Cl/Br-DBPs in the disinfection process of different water samples.

    PubMed

    Shao, Yanan; Pan, Zihan; Rong, Chuan; Wang, Yinghui; Zhu, Hongxiang; Zhang, Yuanyuan; Yu, Kefu

    2018-05-21

    During chlorine disinfection process, reactions between the disinfectant and 17β-estradiol (E2) lead to the formation of halogenated disinfection byproducts (DBPs) which can be a risk to both ecosystem and human health. The degradation and transformation products of E2 in sodium hypochlorite (NaClO) disinfection processes of different water samples were investigated. The reaction kinetics research showed that the degradation rates of E2 were considerably dependent on the initial pH value and the types of water samples. In fresh water, synthetic marine aquaculture water and seawater, the reaction rate constant was 0.133 min -1 , 2.067 min -1 and 2.592 min -1 , respectively. The reasons for the above phenomena may be due to the different concentrations of bromide ions (Br - ) in these three water samples which could promote the reaction between NaClO and E2. Furthermore, Br - could also cause the formation of brominated DBPs (Br-DBPs). The main DBPs, reaction centers and conceivable reaction pathways were explored. Seven halogenated DBPs have been observed including three chlorinated DBPs (Cl-DBPs) and four Br-DBPs. The active sites of E2 were found to be the pentabasic cyclic ring and the ortho position of the phenol moiety as well as C9-C10 position. The identified Cl/Br-DBPs were also confirmed in actual marine aquaculture water from a shrimp pond. The comparison of bio-concentration factors (BCF) values based on calculation of EPI-suite showed that the toxicities of the Br-DBPs were stronger than that of their chloride analogues. The absorbable organic halogens (AOX) analysis also suggested that the DBPs produced in the marine aquaculture water were more toxic than that in the fresh water system. Copyright © 2018 Elsevier Ltd. All rights reserved.

  1. EFFECTS OF 20 WEEK EXPOSURES IN FEMALE SPRAGUE-DAWLEY (S-D) RATS TO DIBROMOACETIC ACID, A DRINKING WATER DISINFECTANT BY-PRODUCT

    EPA Science Inventory

    Effects of 20 week exposures in female Sprague-Dawley (S-D) rats to the drinking water disinfection by-product dibromoacetic acid. A S Murr and J M Goldman, Endocrinol. Br., RTD, NHEERL, ORD, US EPA, Res. Tri. Pk, NC. Sponsor: Audrey Cummings

    The drinking water disinfect...

  2. EFFECTS OF 20 WEEK EXPOSURES IN FEMALE SPRAGUE-DAWLEY (S-D) RATS TO THE DRINKING WATER DISINFECTION BY-PRODUCT DIBROMOACETIC ACID

    EPA Science Inventory

    Effects of 20 week exposures in female Sprague-Dawley (S-D) rats to the drinking water disinfection by-product dibromoacetic acid. A S Murr and J M Goldman, Endocrinol. Br., RTD, NHEERL, ORD, US EPA, Res. Tri. Pk, NC. Sponsor: Audrey Cummings

    The drinking water disinfect...

  3. Drinking water biofilms on copper and stainless steel exhibit specific molecular responses towards different disinfection regimes at waterworks.

    PubMed

    Jungfer, Christina; Friedrich, Frank; Varela Villarreal, Jessica; Brändle, Katharina; Gross, Hans-Jürgen; Obst, Ursula; Schwartz, Thomas

    2013-09-01

    Biofilms growing on copper and stainless steel substrata in natural drinking water were investigated. A modular pilot-scale distribution facility was installed at four waterworks using different raw waters and disinfection regimes. Three-month-old biofilms were analysed using molecular biology and microscopy methods. High total cell numbers, low counts of actively respiring cells and low numbers of cultivable bacteria indicated the high abundance of viable but not cultivable bacteria in the biofilms. The expression of the recA SOS responsive gene was detected and underlined the presence of transcriptionally active bacteria within the biofilms. This effect was most evident after UV disinfection, UV oxidation and UV disinfection with increased turbidity at waterworks compared to chemically treated and non-disinfected systems. Furthermore, live/dead staining techniques and environmental scanning electron microscopy imaging revealed the presence of living and intact bacteria in biofilms on copper substrata. Cluster analyses of DGGE profiles demonstrated differences in the composition of biofilms on copper and steel materials.

  4. ULTRAVIOLET DISINFECTION STUDIES WITH CCL LISTED MICROORGANISMS

    EPA Science Inventory

    Resistance to ultraviolet (UV) disinfection is an essential aspect regarding all microbial groups listed on the CCL. The U.S. drinking water industry is interested in including UV light treatment as an amendment to conventional treatment for disinfecting water supplies. UV disi...

  5. Effect of iodine disinfectant source and water quality parameters on soluble iodine speciation

    NASA Technical Reports Server (NTRS)

    Silverstein, Joann; Hurst, Charles; Barkley, Robert; Dunham, Andrew

    1993-01-01

    Investigations of iodine species distribution of various aqueous solutions of iodine disinfectants and water from equilibrated suspensions of triodide and pentaiodide resins were done at the University of Colorado for the Center for Space Environmental Health during 1992 and 1993. Direct measurements of three individual iodine species: I(-), I2 and I3(-), were made. In addition three measures of total titratable iodine species were used. It has been found that I2 and I3(-) solutions produce a significant fraction of the non-disinfecting species iodine I(-), ranging from 50 to 80% of added iodine, respectively, at pH values of approximately 5. Correspondingly, I2 solutions produce more than twice the concentration of disinfecting iodine species per mass iodine dose than I3(-) solutions. Both I(-) and I2 species were found in aqeuous extracts of pentaiodide resin, although no soluble species were detected with triiodide resin.

  6. INTEGRATED DISINFECTION BYPRODUCTS MIXTURES RESEARCH: COMPREHENSIVE CHARACTERIZATION OF WATER CONCENTRATES PREPARED FROM CHLORINATED AND OZONATED/POSTCHLORINATED DRINKING WATER

    EPA Science Inventory

    This article describes the disinfection byproduct (DBP) characterization portion of a series of experiments designed for comprehensive chemical and toxicological evaluation of two drinking water concentrates containing highly complex mixtures of DBP. This project, called the Four...

  7. Silver-based Antibacterial Surfaces for Drinking Water Disinfection - An overview

    EPA Science Inventory

    Risks associated with current disinfection techniques, including the formation of disinfection by-products and multi-drug resistant bacterial species, have prompted the exploration of advanced disinfection methods. One such technique employs silver nanoparticles incorporation on ...

  8. Evidence of arsenic release promoted by disinfection by-products within drinking-water distribution systems.

    PubMed

    Andra, Syam S; Makris, Konstantinos C; Botsaris, George; Charisiadis, Pantelis; Kalyvas, Harris; Costa, Costas N

    2014-02-15

    Changes in disinfectant type could trigger a cascade of reactions releasing pipe-anchored metals/metalloids into finished water. However, the effect of pre-formed disinfection by-products on the release of sorbed contaminants (arsenic-As in particular) from drinking water distribution system pipe scales remains unexplored. A bench-scale study using a factorial experimental design was performed to evaluate the independent and interaction effects of trihalomethanes (TTHM) and haloacetic acids (HAA) on arsenic (As) release from either scales-only or scale-biofilm conglomerates (SBC) both anchored on asbestos/cement pipe coupons. A model biofilm (Pseudomonas aeruginosa) was allowed to grow on select pipe coupons prior experimentation. Either TTHM or HAA individual dosing did not promote As release from either scales only or SBC, detecting <6 μg AsL(-1) in finished water. In the case of scales-only coupons, the combination of the highest spike level of TTHM and HAA significantly (p<0.001) increased dissolved and total As concentrations to levels up to 16 and 95 μg L(-1), respectively. Similar treatments in the presence of biofilm (SBC) resulted in significant (p<0.001) increase in dissolved and total recoverable As up to 20 and 47 μg L(-1), respectively, exceeding the regulatory As limit. Whether or not, our laboratory-based results truly represent mechanisms operating in disinfected finished water in pipe networks remains to be investigated in the field. Copyright © 2013 Elsevier B.V. All rights reserved.

  9. Effect of drinking water disinfection by-products in human peripheral blood lymphocytes and sperm.

    PubMed

    Ali, Aftab; Kurzawa-Zegota, Malgorzata; Najafzadeh, Mojgan; Gopalan, Rajendran C; Plewa, Michael J; Anderson, Diana

    2014-12-01

    Drinking water disinfection by-products (DBPs) are generated by the chemical disinfection of water and may pose hazards to public health. Two major classes of DBPs are found in finished drinking water: haloacetic acids (HAAs) and trihalomethanes (THMs). HAAs are formed following disinfection with chlorine, which reacts with iodide and bromide in the water. Previously the HAAs were shown to be cytotoxic, genotoxic, mutagenic, teratogenic and carcinogenic. To determine the effect of HAAs in human somatic and germ cells and whether oxidative stress is involved in genotoxic action. In the present study both somatic and germ cells have been examined as peripheral blood lymphocytes and sperm. The effects of three HAA compounds: iodoacetic acid (IAA), bromoacetic acid (BAA) and chloroacetic acid (CAA) were investigated. After determining appropriate concentration responses, oxygen radical involvement with the antioxidants, butylated hydroxanisole (BHA) and the enzyme catalase, were investigated in the single cell gel electrophoresis (Comet) assay under alkaline conditions, >pH 13 and the micronucleus assay. In the Comet assay, BHA and catalase were able to reduce DNA damage in each cell type compared to HAA alone. In the micronucleus assay, micronuclei (MNi) were found in peripheral lymphocytes exposed to all three HAAs and catalase and BHA were in general, able to reduce MNi induction, suggesting oxygen radicals play a role in both assays. These observations are of concern to public health since both human somatic and germ cells show similar genotoxic responses. Copyright © 2014. Published by Elsevier B.V.

  10. Disinfection of Spacecraft Potable Water Systems by Photocatalytic Oxidation Using UV-A Light Emitting Diodes

    NASA Technical Reports Server (NTRS)

    Birmele, Michele N.; O'Neal, Jeremy A.; Roberts, Michael S.

    2011-01-01

    Ultraviolet (UV) light has long been used in terrestrial water treatment systems for photodisinfection and the removal of organic compounds by several processes including photoadsorption, photolysis, and photocatalytic oxidation/reduction. Despite its effectiveness for water treatment, UV has not been explored for spacecraft applications because of concerns about the safety and reliability of mercury-containing UV lamps. However, recent advances in ultraviolet light emitting diodes (UV LEDs) have enabled the utilization of nanomaterials that possess the appropriate optical properties for the manufacture of LEDs capable of producing monochromatic light at germicidal wavelengths. This report describes the testing of a commercial-off-the-shelf, high power Nichia UV-A LED (250mW A365nnJ for the excitation of titanium dioxide as a point-of-use (POD) disinfection device in a potable water system. The combination of an immobilized, high surface area photocatalyst with a UV-A LED is promising for potable water system disinfection since toxic chemicals and resupply requirements are reduced. No additional consumables like chemical biocides, absorption columns, or filters are required to disinfect and/or remove potentially toxic disinfectants from the potable water prior to use. Experiments were conducted in a static test stand consisting of a polypropylene microtiter plate containing 3mm glass balls coated with titanium dioxide. Wells filled with water were exposed to ultraviolet light from an actively-cooled UV-A LED positioned above each well and inoculated with six individual challenge microorganisms recovered from the International Space Station (ISS): Burkholderia cepacia, Cupriavidus metallidurans, Methylobacterium fujisawaense, Pseudomonas aeruginosa, Sphingomonas paucimobilis and Wautersia basilensis. Exposure to the Nichia UV-A LED with photocatalytic oxidation resulted in a complete (>7-log) reduction of each challenge bacteria population in <180 minutes of contact

  11. Response of Simulated Drinking Water Biofilm Mechanical and Structural Properties to Long-Term Disinfectant Exposure.

    PubMed

    Shen, Yun; Huang, Conghui; Monroy, Guillermo L; Janjaroen, Dao; Derlon, Nicolas; Lin, Jie; Espinosa-Marzal, Rosa; Morgenroth, Eberhard; Boppart, Stephen A; Ashbolt, Nicholas J; Liu, Wen-Tso; Nguyen, Thanh H

    2016-02-16

    Mechanical and structural properties of biofilms influence the accumulation and release of pathogens in drinking water distribution systems (DWDS). Thus, understanding how long-term residual disinfectants exposure affects biofilm mechanical and structural properties is a necessary aspect for pathogen risk assessment and control. In this study, elastic modulus and structure of groundwater biofilms was monitored by atomic force microscopy (AFM) and optical coherence tomography (OCT) during three months of exposure to monochloramine or free chlorine. After the first month of disinfectant exposure, the mean stiffness of monochloramine- or free-chlorine-treated biofilms was 4 to 9 times higher than those before treatment. Meanwhile, the biofilm thickness decreased from 120 ± 8 μm to 93 ± 6-107 ± 11 μm. The increased surface stiffness and decreased biofilm thickness within the first month of disinfectant exposure was presumably due to the consumption of biomass. However, by the second to third month during disinfectant exposure, the biofilm mean stiffness showed a 2- to 4-fold decrease, and the biofilm thickness increased to 110 ± 7-129 ± 8 μm, suggesting that the biofilms adapted to disinfectant exposure. After three months of the disinfectant exposure process, the disinfected biofilms showed 2-5 times higher mean stiffness (as determined by AFM) and 6-13-fold higher ratios of protein over polysaccharide, as determined by differential staining and confocal laser scanning microscopy (CLSM), than the nondisinfected groundwater biofilms. However, the disinfected biofilms and nondisinfected biofilms showed statistically similar thicknesses (t test, p > 0.05), suggesting that long-term disinfection may not significantly remove net biomass. This study showed how biofilm mechanical and structural properties vary in response to a complex DWDS environment, which will contribute to further research on the risk assessment and control of biofilm-associated-pathogens in DWDS.

  12. Drowning in Disinfection Byproducts? Swimming Pool Water Quality

    EPA Science Inventory

    Disinfection is mandatory for swimming pools, because transmission of disease by bacteria, virus and protozoa is the most significant health issue. However another issue arises, and care should be taken to minimize the risks from disinfection by-products (DBPs). Public pools are ...

  13. Evaluation of the efficiency of the photo Fenton disinfection of natural drinking water source during the rainy season in the Sahelian region.

    PubMed

    Ndounla, J; Pulgarin, C

    2014-09-15

    The photo-disinfection of water from two different wells (W1, pH: 4.6-5.1 ± 0.02) and (W2 pH: 5.6-5.7 ± 0.02) was carried out during the rainy season at Ouagadougou-Burkina Faso, West Africa. The weather variation during the rainy season significantly affects the photo-disinfection processes (solar disinfection and photo-Fenton). The dilution of the water by rainwater highly affected the chemical composition of the wells' water used in this study; very low iron contents Compared to the ones recorded during the dry season were recorded in all water samples. Both photo-disinfection processes were used to treat 25 L of water in a compound parabolic collector (CPC). None of them have shown the total inactivation of both wild enteric bacteria strains (total coliforms/E. coli and Salmonella spp.) involved in the treatment. However, the total coliforms/E. coli strains were totally inactivated during the exposure under most of the photo-Fenton treatment. Also, the remaining strains, especially those of Salmonella spp. were achieved during the subsequent 24h of dark storage under the action of the Fenton process. Under uniquely solar radiation, total inactivation was recorded only in the total coliforms/E. coli strains. The impact of the available irradiance on the efficiency of the photo-Fenton disinfection of natural water was highlighted during the exposure under high intermittent solar radiation. The impact of the HCO3(-) concentration of both wells' water on the evolution of the pH during the photo-disinfection was recorded. Drastic decrease was noticed after the initial fast increase in presence of low HCO3(-) concentration while a steady state was observed after the increase in presence of higher concentration. The redox activities of the nitrogen components of the water during both photo-disinfection processes have led to increased concentration of nitrite in all the cases and variations were noticed in that of nitrate and ammonia. Copyright © 2014 Elsevier B

  14. Disinfection of Vegetative Cells of Bacillus anthracis

    DTIC Science & Technology

    2016-03-01

    1. INTRODUCTION Disinfection of Bacillus anthracis spores in drinking water is well documented in peer-reviewed literature (Adcock et al., 2004... Disinfection kinetics of vegetative cells of Bacillus anthracis in water with free available chlorine ([FAC] 2 mg/L) and monochloramine ([MC] 2 mg/L) were...anthracis. Bacillus anthracis cells Drinking water Chlorine demand-free (CDF

  15. The study of interrelationship between raw water quality parameters, chlorine demand and the formation of disinfection by-products

    NASA Astrophysics Data System (ADS)

    Abdullah, Md. Pauzi; Yee, Lim Fang; Ata, Sadia; Abdullah, Abass; Ishak, Basar; Abidin, Khairul Nidzham Zainal

    Disinfection is the most crucial process in the treatment of drinking water supply and is the final barrier against bacteriological impurities in drinking water. Chlorine is the primary disinfectant used in the drinking water treatment process throughout Malaysia. However, the occurrence of various disinfection by-products such as trihalomethanes (THM) and haloacetic acids created a major issue on the potential health hazards which may pose adverse health effects in both human and animals. To simulate real water treatment conditions and to represent the conditions inherent in a tropical country, this study was performed at an urbanized water treatment plant with a daily production of about 549,000 m 3 of treated water. The purpose of this work is to examine the relationship between the water quality parameters in the raw water with chlorine demand and the formation of disinfection by-products. This study also investigated the possibility of the statistical model applications for the prediction of chlorine demand and the THM formation. Two models were developed to estimate the chlorine demand and the THM formation. For the statistical evaluation, correlation and simple linear regression analysis were conducted using SPSS. The results of Kolmogorov-Smirnov test for the estimation of goodness-of-fit of the dependent variables of the models to the normal distribution showed that all the dependent variables followed the normal distribution at significance level of 0.05. Good linear correlations were observed between the independent parameters and formation of THM and the chlorine demand. This study also revealed that ammonia and the specific ultraviolet absorbent (SUVA) were the function of chlorine consumption in the treatment process. Chlorine dosage and SUVA increase the yield of THM. Chlorine demand and THM formation was moderately sensitive, but significant to the pH. The level of significance ( α) for the statistical tests and the inclusion of a variable in the

  16. DISINFECTION

    EPA Science Inventory

    The primary goal of the disinfection process in drinking water treatment is the inactivation of microbial pathogens. These pathogens comprise a diverse group of organisms which serve as the etiological agents of waterborne disease. Included in this group are bacterial, viral and ...

  17. A new silver based composite material for SPA water disinfection.

    PubMed

    Tartanson, M A; Soussan, L; Rivallin, M; Chis, C; Penaranda, D; Lapergue, R; Calmels, P; Faur, C

    2014-10-15

    A new composite material based on alumina (Al2O3) modified by two surface nanocoatings - titanium dioxide (TiO2) and silver (Ag) - was studied for spa water disinfection. Regarding the most common microorganisms in bathing waters, two non-pathogenic bacteria Escherichia coli (Gram-negative) and Staphylococcus epidermidis (Gram positive) were selected as surrogates for bacterial contamination. The bactericidal properties of the Al2O3-TiO2-Ag material were demonstrated under various operating conditions encountered in spa water (temperature: 22-37 °C, presence of salt: CaCO3 or CaCl2, high oxygen content, etc.). Total removal of 10(8) CFU mL(-1) of bacteria was obtained in less than 10 min with 16 g L(-1) of material. Best results were observed for both conditions: a temperature of 37 °C and under aerobic condition; this latest favouring Reactive Oxygen Species (ROS) generation. The CaCO3 salt had no impact on the bactericidal activity of the composite material and CaCl2 considerably stabilized the silver desorption from the material surface thanks to the formation of AgCl precipitate. Preliminary tests of the Al2O3-TiO2-Ag bactericidal behaviour in a continuous water flow confirmed that 2 g L(-1) of material eliminated more than 90% of a 2.0 × 10(8) CFU mL(-1) bacterial mixture after one water treatment recycle and reached the disinfection standard recommended by EPA (coliform removal = 6 log) within 22 h. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. Decontamination formulations for disinfection and sterilization

    DOEpatents

    Tucker, Mark D.; Engler, Daniel E.

    2007-09-18

    Aqueous decontamination formulations that neutralize biological pathogens for disinfection and sterilization applications. Examples of suitable applications include disinfection of food processing equipment, disinfection of areas containing livestock, mold remediation, sterilization of medical instruments and direct disinfection of food surfaces, such as beef carcasses. The formulations include at least one reactive compound, bleaching activator, inorganic base, and water. The formulations can be packaged as a two-part kit system, and can have a pH value in the range of 7-8.

  19. Selective Photocatalytic Disinfection by Coupling StrepMiniSog to the Antibody Catalyzed Water Oxidation Pathway

    PubMed Central

    2016-01-01

    For several decades reactive oxygen species have been applied to water quality engineering and efficient disinfection strategies; however, these methods are limited by disinfection byproduct and catalyst-derived toxicity concerns which could be improved by selectively targeting contaminants of interest. Here we present a targeted photocatalytic system based on the fusion protein StrepMiniSOG that uses light within the visible spectrum to produce reactive oxygen species at a greater efficiency than current photosensitizers, allowing for shorter irradiation times from a fully biodegradable photocatalyst. The StrepMiniSOG photodisinfection system is unable to cross cell membranes and like other consumed proteins, can be degraded by endogenous digestive enzymes in the human gut, thereby reducing the consumption risks typically associated with other disinfection agents. We demonstrate specific, multi-log removal of Listeria monocytogenes from a mixed population of bacteria, establishing the StrepMiniSOG disinfection system as a valuable tool for targeted pathogen removal, while maintaining existing microbial biodiversity. PMID:27617441

  20. Selective Photocatalytic Disinfection by Coupling StrepMiniSog to the Antibody Catalyzed Water Oxidation Pathway.

    PubMed

    Wurtzler, Elizabeth M; Wendell, David

    2016-01-01

    For several decades reactive oxygen species have been applied to water quality engineering and efficient disinfection strategies; however, these methods are limited by disinfection byproduct and catalyst-derived toxicity concerns which could be improved by selectively targeting contaminants of interest. Here we present a targeted photocatalytic system based on the fusion protein StrepMiniSOG that uses light within the visible spectrum to produce reactive oxygen species at a greater efficiency than current photosensitizers, allowing for shorter irradiation times from a fully biodegradable photocatalyst. The StrepMiniSOG photodisinfection system is unable to cross cell membranes and like other consumed proteins, can be degraded by endogenous digestive enzymes in the human gut, thereby reducing the consumption risks typically associated with other disinfection agents. We demonstrate specific, multi-log removal of Listeria monocytogenes from a mixed population of bacteria, establishing the StrepMiniSOG disinfection system as a valuable tool for targeted pathogen removal, while maintaining existing microbial biodiversity.

  1. Disinfection and reduction of organic load of sewage water by electron beam radiation

    NASA Astrophysics Data System (ADS)

    Maruthi, Y. Avasn; Das, N. Lakshmana; Hossain, Kaizar; Sarma, K. S. S.; Rawat, K. P.; Sabharwal, S.

    2011-09-01

    The efficacy of electron beam radiation for the disinfection and reduction of organic load of sewage water was assessed with ILU-6 Accelerator at Radiation Technology Development Division of the Bhabha Atomic Research Centre, Mumbai India. The current problem on environmental health in relation to water pollution insists for the safe disposal of sewage water. In general, sewage water comprises heterogeneous organic based chemicals as well as pathogens. EB treatment of the wastewater has found to be very effective in reducing the pathogens as well as organic load. EB dose of 1.5 kGy was sufficient for complete elimination of total coli forms. The experimental results elucidated the reduction of biological oxygen demand—BOD (35 and 51.7%) in both inlet and outlet sewage samples. Similarly reduction of chemical oxygen demand—COD was observed (37.54 and 52.32%) in both sewage samples with respect to increase in irradiation doses (0.45-6 kGy). The present study demonstrated the potential of ionizing radiation for disinfection of sewage and to increase the water quality of the wastewater by decreasing BOD and COD. So, the irradiation sewage water can find its application either in agriculture for irrigation, in industry for cooling purpose and some selected domestic purposes.

  2. Reduction of Norwalk Virus, Poliovirus 1, and Bacteriophage MS2 by Ozone Disinfection of Water

    PubMed Central

    Shin, Gwy-Am; Sobsey, Mark D.

    2003-01-01

    Norwalk virus and other human caliciviruses (noroviruses) are major agents of gastroenteritis, and water is a major route of their transmission. In an effort to control Norwalk virus in drinking water, Norwalk virus reduction by bench-scale ozone disinfection was determined using quantitative reverse transcription (RT)-PCR for virus assays. Two other enteric viruses, poliovirus 1 and coliphage MS2, were included for comparison, and their reductions were assayed by infectivity assays as well as by RT-PCR. Virus reductions by ozone were determined using a dose of 0.37 mg of ozone/liter at pH 7 and 5°C for up to 5 min. Based on two RT-PCR assays, the reductions of Norwalk virus were >3 log10 within a contact time of 10 s, and these were similar to the reductions of the other two viruses determined by the same assay methods. Also, the virus reductions detected by RT-PCR assays were similar to those detected by infectivity assays, indicating that the RT-PCR assay is a reliable surrogate assay for both culturable and nonculturable viruses disinfected with ozone. Overall, the results of this study indicate that Norwalk virus as well as other enteric viruses can be reduced rapidly and extensively by ozone disinfection and that RT-PCR is a useful surrogate assay for both culturable and nonculturable viruses disinfected with ozone. PMID:12839770

  3. Reduction of Norwalk virus, poliovirus 1, and bacteriophage MS2 by ozone disinfection of water.

    PubMed

    Shin, Gwy-Am; Sobsey, Mark D

    2003-07-01

    Norwalk virus and other human caliciviruses (noroviruses) are major agents of gastroenteritis, and water is a major route of their transmission. In an effort to control Norwalk virus in drinking water, Norwalk virus reduction by bench-scale ozone disinfection was determined using quantitative reverse transcription (RT)-PCR for virus assays. Two other enteric viruses, poliovirus 1 and coliphage MS2, were included for comparison, and their reductions were assayed by infectivity assays as well as by RT-PCR. Virus reductions by ozone were determined using a dose of 0.37 mg of ozone/liter at pH 7 and 5 degrees C for up to 5 min. Based on two RT-PCR assays, the reductions of Norwalk virus were >3 log(10) within a contact time of 10 s, and these were similar to the reductions of the other two viruses determined by the same assay methods. Also, the virus reductions detected by RT-PCR assays were similar to those detected by infectivity assays, indicating that the RT-PCR assay is a reliable surrogate assay for both culturable and nonculturable viruses disinfected with ozone. Overall, the results of this study indicate that Norwalk virus as well as other enteric viruses can be reduced rapidly and extensively by ozone disinfection and that RT-PCR is a useful surrogate assay for both culturable and nonculturable viruses disinfected with ozone.

  4. Comet assay and micronucleus test in circulating erythrocytes of Cyprinus carpio specimens exposed in situ to lake waters treated with disinfectants for potabilization.

    PubMed

    Buschini, A; Martino, A; Gustavino, B; Monfrinotti, M; Poli, P; Rossi, C; Santoro, M; Dörr, A J M; Rizzoni, M

    2004-02-14

    The detection of a possible genotoxic effect of surface water treated with disinfectants for potabilization is the aim of the present work. The Comet assay and the micronucleus test were applied in circulating erythrocytes of Cyprinus carpio. Young specimens (20-30 g) were exposed in experimental basins, built within the potabilization plant of Castiglione del Lago (Perugia, Italy). In this plant the water of the Trasimeno Lake is treated and disinfected for potabilization before it is distributed to the people in the net of drinkable water. A continuous flow of water at a constant rate was supplied to basins; the water was continuously treated at a constant concentration with one of the three tested disinfectants (sodium hypochlorite, peracetic acid and chloride dioxide), one control basin being supplied with untreated water. Three sampling campaigns were performed: October 2000, February 2001 and June 2001. Repeated blood samplings through intracardiac punctures allowed to follow the same fish populations after different exposure times: before introduction of the disinfectant, and 10 or 20 days afterwards. An additional blood sampling was performed 3 h after addition of the disinfectant in other, simultaneously exposed, fish populations. Genotoxic damage was shown in fish exposed to water disinfected with sodium hypochlorite and chloride dioxide. The Comet assay showed an immediate response, i.e. DNA damage that was induced directly in circulating erythrocytes, whereas micronuclei reached their highest frequencies at later sampling times, when a genotoxic damage in stem cells of the cephalic kidney is expressed in circulating erythrocytes. The quality of the untreated surface water seems to be the most important parameter for the long-term DNA damage in circulating erythrocytes.

  5. Evaluation of the Solar Water Disinfection Method Using an Ultraviolet Measurement Device

    NASA Astrophysics Data System (ADS)

    Leung, H.

    2015-12-01

    Drinking water security is a growing problem for the population of planet Earth. According to WHO, more than 750 million people on our planet lack access to safe drinking water, resulting in approximately 502,000 diarrhoea deaths in 2012. In order to solve this problem, the Swiss water research institute, Eawag, has developed a method of solar water disinfection, called, "SODIS" The theory of SODIS is simple to understand: a clear plastic bottle filled with water is placed under full sunlight for at least 6 hours. The ultraviolet radiation kills the pathogens in the water, making the originally contaminated water safe for drinking. In order to improve this method, Helioz, an Austrian social enterprise, has created the WADI, a UV measurement device which determines when water is safe for drinking using the SODIS method. When using the WADI, the device should be placed under the sun and surrounded with bottles of water that need to be decontaminated. There is a UV sensor on the WADI, and since the bottles of water and the WADI will have equal exposure to sunlight, the WADI will be able to measure the impact of the sunlight on the contaminated water. This experiment tests the accuracy of the WADI device regarding the time interval needed for contaminated water to be disinfected. The experiment involves using the SODIS method to purify bottles of water contaminated with controlled samples of E. coli. Samples of the water are taken at different time intervals, and the E. coli levels are determined by growing the bacteria from the water samples on agar plates. Ultimately, this helps determine when the water is safe for drinking, and are compared against the WADI's measurements to test the reliability of the device.

  6. [Water disinfection by the combined exposure to super-high frequency energy and available chlorine produced during water electrolysis].

    PubMed

    Klimarev, S I; Siniak, Iu E

    2014-01-01

    The article reports the results of studying the effects on polluted water of SHF-energy together with the residual free (active) chlorine as a by-product of electrolysis action on dissolved chlorine-containing salts. Purpose of the studies was to evaluate input of these elements to the water disinfection effect. The synergy was found to kill microorganisms without impacts on the physicochemical properties of processed water or nutrient medium; therefore, it can be used for water treatment, and cultivation of microorganisms in microbiology.

  7. Solar disinfection of drinking water contained in transparent plastic bottles: characterizing the bacterial inactivation process.

    PubMed

    McGuigan, K G; Joyce, T M; Conroy, R M; Gillespie, J B; Elmore-Meegan, M

    1998-06-01

    A series of experiments is reported to identify and characterize the inactivation process in operation when drinking water, heavily contaminated with a Kenyan isolate of Escherichia coli, is stored in transparent plastic bottles that are then exposed to sunlight. The roles of optical and thermal inactivation mechanisms are studied in detail by simulating conditions of optical irradiance, water turbidity and temperature, which were recorded during a series of solar disinfection measurements carried out in the Kenyan Rift Valley. Optical inactivation effects are observed even in highly turbid water (200 ntu) and at low irradiances of only 10 mW cm-2. Thermal inactivation is found to be important only at water temperatures above 45 degrees C, at which point strong synergy between optical and thermal inactivation processes is observed. The results confirm that, where strong sunshine is available, solar disinfection of drinking water is an effective, low cost method for improving water quality and may be of particular use to refugee camps in disaster areas. Strategies for improving bacterial inactivation are discussed.

  8. A novel strategy for water disinfection with a AgNPs/gelatin sponge filter.

    PubMed

    Wei, Feng; Zhao, Xiaole; Li, Chao; Han, Xiaojun

    2018-05-05

    Disinfection of bacteria in water with sustainable and energy-efficient methods is still a great challenge. Herein, a novel gelatin sponge with embedded AgNPs is fabricated via freeze-drying using gelatin as the reducing agent to synthesize AgNPs in situ. UV-vis spectroscopy, HRTEM, XRD, and XPS characterization prove the formation of AgNPs with an average size of 8.55 ± 0.35 nm. TEM and SEM images confirm the even distribution of AgNPs throughout the AgNPs/gelatin sponges. The composite sponge has a low bulk density of 20 ± 3.5 mg/cm 3 and a pore size of 6.2 ± 1.5 μm. The AgNPs/gelatin sponges exhibit excellent antibacterial performance to E. coli in water, probably by destroying their cell membranes. The porous AgNPs/gelatin composite sponges are promising filter materials for water disinfection. The removal rate of AgNPs/gelatin composite sponges on E. coli reached almost 100%. Graphical abstract ᅟ.

  9. Comparative genotoxicity of nitrosamine drinking water disinfection byproducts in Salmonella and mammalian cells.

    PubMed

    Wagner, Elizabeth D; Hsu, Kang-Mei; Lagunas, Angelica; Mitch, William A; Plewa, Michael J

    2012-01-24

    Nitrosamine water disinfection byproducts (DBPs) are an emerging class of non-halogenated, nitrogen-containing water contaminants. Five nitrosamine DBPs were analyzed for genotoxicity (N-nitrosodimethylamine (NDMA), N-nitrosopiperidine (NPIP), N-nitrosopyrrolidine (NPYR), N-nitrosomorpholine (NMOR) and N-nitrosodiphenylamine (NDPhA). Using Salmonella typhimurium strain YG7108 the descending rank order of mutagenicity was NDMA>NPIP>NMOR>NPYR; NDPhA was not mutagenic. We developed and calibrated an exogenous S9 mix that was highly effective in activating NDMA in Chinese hamster ovary (CHO) cells using the SCGE (Comet) assay. The descending rank order for genotoxicity was NDMA>NPIP>NMOR. NDPhA was genotoxic only at one concentration and NPYR was not genotoxic. The genotoxic potencies in S. typhimurium and CHO cells were highly correlated. Based on their comparative genotoxicity attention should be focused on the generation and occurrence of NDMA, NPIP and NMOR. Current drinking water disinfection processes may need to be modified such that the generation of nitrosamine DBPs is effectively limited in order to protect the environment and the public health. © 2011 Elsevier B.V. All rights reserved.

  10. Elimination of disinfection byproduct formation potential in reclaimed water during solar light irradiation.

    PubMed

    Qian-Yuan, Wu; Chao, Li; Ye, Du; Wen-Long, Wang; Huang, Huang; Hong-Ying, Hu

    2016-05-15

    Ecological storage of reclaimed water in ponds and lakes is widely applied in water reuse. During reclaimed water storage, solar light can degrade pollutants and improve water quality. This study investigated the effects of solar light irradiation on the disinfection byproduct formation potential in reclaimed water, including haloacetonitriles (HANs), trichloronitromethane (TCNM), trihalomethanes (THMs), haloketones (HKs) and chloral hydrate (CH). Natural solar light significantly decreased the formation potential of HANs, TCNM, and HKs in reclaimed water, but had a limited effect on the formation potential of THMs and CH. Ultraviolet (UV) light in solar radiation played a dominant role in the decrease of the formation potential of HANs, TCNM and HKs. Among the disinfection byproducts, the removal kinetic constant of dichloroacetonitrile (DCAN) with irradiation dose was much larger than those for dichloropropanone (1,1-DCP), trichloropropanone (1,1,1-TCP) and TCNM. During solar irradiation, fluorescence spectra intensities of reclaimed water also decreased significantly. The removal of tyrosine (Tyr)-like and tryptophan (Trp)-like protein fluorescence spectra intensity volumes was correlated to the decrease in DCAN formation potential. Solar irradiation was demonstrated to degrade Trp, Tyr and their DCAN formation potential. The photolysis products of Trp after solar irradiation were detected as kynurenine and tryptamine, which had chloroform, CH and DCAN formation potential lower than those of Trp. Copyright © 2016. Published by Elsevier Ltd.

  11. The potential of solar water disinfection as a household water treatment method in peri-urban Zimbabwe

    NASA Astrophysics Data System (ADS)

    Murinda, Sharon; Kraemer, Silvie

    The potential for reducing diarrhoea morbidity and improving the health status of children in developing countries using solar water disinfection (SODIS) has been demonstrated in past research. A baseline survey was conducted to explore the feasibility and necessity of introducing SODIS in peri-urban communities of Zimbabwe. The survey sought to establish drinking water quality in these areas and to determine the health and hygiene beliefs as well as practices related to water handling in the household. Microbiological water quality tests and personal interviews were carried out in Epworth township and Hopley farm, two peri-urban areas near the capital of Zimbabwe, Harare. These two areas are among the poorest settlements around Harare with 80% of inhabitants being informal settlers. Community meetings were held to introduce solar water disinfection prior to the survey. This was followed by administration of questionnaires, which aimed to investigate whether the community had ever heard about SODIS, whether they were practicing it, other means that were being used to treat drinking water as well as health and hygiene beliefs and practices. It was found out that most households cannot afford basic water treatment like boiling as firewood is expensive. People generally reported that the water was not palatable due to objectionable odour and taste. Microbiological water quality tests proved that drinking water was contaminated in both areas, which makes the water unsafe for drinking and shows the necessity of treatment. Although the majority of people interviewed had not heard of SODIS prior to the interview, attitudes towards its introduction were very positive and the intention to do SODIS in the future was high. Amongst the ones who had heard about SODIS before the study, usage was high. Plastic PET bottles, which were used for the SODIS experiments are currently unavailable and this has been identified as a potential hindrance to the successful implementation of

  12. Bioanalytical assessment of the formation of disinfection byproducts in a drinking water treatment plant.

    PubMed

    Neale, Peta A; Antony, Alice; Bartkow, Michael E; Farré, Maria José; Heitz, Anna; Kristiana, Ina; Tang, Janet Y M; Escher, Beate I

    2012-09-18

    Disinfection of drinking water is the most successful measure to reduce water-borne diseases and protect health. However, disinfection byproducts (DBPs) formed from the reaction of disinfectants such as chlorine and monochloramine with organic matter may cause bladder cancer and other adverse health effects. In this study the formation of DBPs through a full-scale water treatment plant serving a metropolitan area in Australia was assessed using in vitro bioanalytical tools, as well as through quantification of halogen-specific adsorbable organic halogens (AOXs), characterization of organic matter, and analytical quantification of selected regulated and emerging DBPs. The water treatment train consisted of coagulation, sand filtration, chlorination, addition of lime and fluoride, storage, and chloramination. Nonspecific toxicity peaked midway through the treatment train after the chlorination and storage steps. The dissolved organic matter concentration decreased after the coagulation step and then essentially remained constant during the treatment train. Concentrations of AOXs increased upon initial chlorination and continued to increase through the plant, probably due to increased chlorine contact time. Most of the quantified DBPs followed a trend similar to that of AOXs, with maximum concentrations observed in the final treated water after chloramination. The mostly chlorinated and brominated DBPs formed during treatment also caused reactive toxicity to increase after chlorination. Both genotoxicity with and without metabolic activation and the induction of the oxidative stress response pathway showed the same pattern as the nonspecific toxicity, with a maximum activity midway through the treatment train. Although measured effects cannot be directly translated to adverse health outcomes, this study demonstrates the applicability of bioanalytical tools to investigate DBP formation in a drinking water treatment plant, despite bioassays and sample preparation not

  13. MUTAGENICITY IN SALMONELLA AND DNA DAMAGE IN THE CHO/COMET ASSAY INDUCED BY NITROHALOMETHANES, A NOVEL CLASS OF DRINKING WATER DISINFECTION BY-PRODUCTS

    EPA Science Inventory

    Mutagenicity in Salmonella and DNA Damage in the CHO/Comet Assay Induced by Nitrohalomethanes, a Novel Class of Drinking Water Disinfection By-Products.

    Halomethanes are a class of drinking water disinfection by-products (DBPs) whose genotoxicity has been studied extensi...

  14. Disparity in disinfection byproducts concentration between hot and cold tap water.

    PubMed

    Liu, Boning; Reckhow, David A

    2015-03-01

    The quality of water entering a distribution system may differ substantially from the quality at the point of exposure to the consumer. This study investigated temporal variations in the levels of regulated and non-regulated disinfection byproducts (DBPs) in cold and hot tap water in a home on a medium-sized municipal water system. In addition, samples were collected directly from the water plant with some being held in accordance with a simulated distribution system (SDS) test protocol. The location for this work was a system in western Massachusetts, USA that uses free chlorine as a final disinfectant. Very little short term variability of DBPs at the point of entry (POE) was observed. The concentration of DBPs in the time-variable SDS test was similar to concentrations in the cold water tap. For most DBPs, the concentrations continued to increase as the cold water tap sample was held for the time-variable SDS incubation period. However, the impact of heating on DBP levels was compound specific. For example, the concentrations of trihalomethanes (THMs), dichloroacetic acid (DCAA) and chloropicrin (CP) were substantially higher in the hot water tap than in the cold water time-variable SDS samples. In contrast, the concentration of trichloroacetic acid (TCAA) was lower in the heated hot tap water, but about equal to that observed in the cold tap water. The situation was more pronounced for dichloroacetonitrile (DCAN), bromodichloroacetic acid (BDCAA), bromochloroacetic acid (BCAA) and 1,1,1-trichloropropanone (TCP), which all showed lower concentrations in the hot water then in either of the cold water samples (instantaneous or time-variable SDS). The latter was viewed as a clear indication of thermally-induced decomposition. The ratio of unknown total organic halide (UTOX) to TOX was substantially lower in the hot tap water as the THM to TOX ratio became correspondingly larger. The results of this study show that DBP exposure in the home is not well represented by

  15. Predictive model for disinfection by-product in Alexandria drinking water, northern west of Egypt.

    PubMed

    Abdullah, Ali M; Hussona, Salah El-dien

    2013-10-01

    Chlorine has been utilized in the early stages of water treatment processes as disinfectant. Disinfection for drinking water reduces the risk of pathogenic infection but may pose a chemical threat to human health due to disinfection residues and their by-products (DBP) when the organic and inorganic precursors are present in water. In the last two decades, many modeling attempts have been made to predict the occurrence of DBP in drinking water. Models have been developed based on data generated in laboratory-scale and field-scale investigations. The objective of this paper is to develop a predictive model for DBP formation in the Alexandria governorate located at the northern west of Egypt based on field-scale investigations as well as laboratory-controlled experimentations. The present study showed that the correlation coefficient between trihalomethanes (THM) predicted and THM measured was R (2)=0.88 and the minimum deviation percentage between THM predicted and THM measured was 0.8 %, the maximum deviation percentage was 89.3 %, and the average deviation was 17.8 %, while the correlation coefficient between dichloroacetic acid (DCAA) predicted and DCAA measured was R (2)=0.98 and the minimum deviation percentage between DCAA predicted and DCAA measured was 1.3 %, the maximum deviation percentage was 47.2 %, and the average deviation was 16.6 %. In addition, the correlation coefficient between trichloroacetic acid (TCAA) predicted and TCAA measured was R (2)=0.98 and the minimum deviation percentage between TCAA predicted and TCAA measured was 4.9 %, the maximum deviation percentage was 43.0 %, and the average deviation was 16.0 %.

  16. Disinfection.

    ERIC Educational Resources Information Center

    Gould, J. P.; Haas, C. N.

    1978-01-01

    Presents a literature review of wastewater disinfection for 1978. This review covers areas such as: (1) mechanisms of inactivation of negative microorganisms by chlorine and ozone; and (2) the effects of various treatment on over-all water quality. A list of 61 references is also presented. (HM)

  17. Minimizing Dissolved Silica to Reduce Ash Content in Reconstituted Waters Used in Disinfection Byproduct Health Effects Research

    EPA Science Inventory

    Previous health effects research used chlorinated, concentrated natural organic matter (NOM) solutions to create whole mixtures of disinfection byproducts (DBPs). Ohio River water was used as the source water to provide the background NOM matrix. Concentrated river water was coll...

  18. What’s in the Pool? A Comprehensive Identification of Disinfection By-products and Assessment of Mutagenicity of Chlorinated and Brominated Swimming Pool Water

    PubMed Central

    Richardson, Susan D.; DeMarini, David M.; Kogevinas, Manolis; Fernandez, Pilar; Marco, Esther; Lourencetti, Carolina; Ballesté, Clara; Heederik, Dick; Meliefste, Kees; McKague, A. Bruce; Marcos, Ricard; Font-Ribera, Laia; Grimalt, Joan O.; Villanueva, Cristina M.

    2010-01-01

    Background Swimming pool disinfectants and disinfection by-products (DBPs) have been linked to human health effects, including asthma and bladder cancer, but no studies have provided a comprehensive identification of DBPs in the water and related that to mutagenicity. Objectives We performed a comprehensive identification of DBPs and disinfectant species in waters from public swimming pools in Barcelona, Catalonia, Spain, that disinfect with either chlorine or bromine and we determined the mutagenicity of the waters to compare with the analytical results. Methods We used gas chromatography/mass spectrometry (GC/MS) to measure trihalomethanes in water, GC with electron capture detection for air, low- and high-resolution GC/MS to comprehensively identify DBPs, photometry to measure disinfectant species (free chlorine, monochloroamine, dichloramine, and trichloramine) in the waters, and an ion chromatography method to measure trichloramine in air. We assessed mutagenicity with the Salmonella mutagenicity assay. Results We identified > 100 DBPs, including many nitrogen-containing DBPs that were likely formed from nitrogen-containing precursors from human inputs, such as urine, sweat, and skin cells. Many DBPs were new and have not been reported previously in either swimming pool or drinking waters. Bromoform levels were greater in brominated than in chlorinated pool waters, but we also identified many brominated DBPs in the chlorinated waters. The pool waters were mutagenic at levels similar to that of drinking water (~ 1,200 revertants/L-equivalents in strain TA100–S9 mix). Conclusions This study identified many new DBPs not identified previously in swimming pool or drinking water and found that swimming pool waters are as mutagenic as typical drinking waters. PMID:20833605

  19. 40 CFR 141.541 - What are significant changes to disinfection practice?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... disinfection practice? 141.541 Section 141.541 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Enhanced Filtration and Disinfection-Systems Serving Fewer Than 10,000 People Disinfection Benchmark § 141.541 What are significant...

  20. IODO-ACID DISINFECTION BY-PRODUCTS IN DRINKING WATER: DOES LC/ESI-MS/MS OFFER AN ADVANTAGE OVER GC/NCI-MS?

    EPA Science Inventory

    As part of a recent Nationwide Disinfection By-Product (DBP) Occurrence Study, iodo-acids were identified for the first time as DBPs in drinking water disinfected with chloramines. The iodo-acids identified included iodoacetic acid, bromoiodoacetic acid, (E)-3-bromo-3-iodo-prope...

  1. Synthesis and characterization of alginate beads encapsulated zinc oxide nanoparticles for bacteria disinfection in water.

    PubMed

    Motshekga, Sarah Constance; Sinha Ray, Suprakas; Maity, Arjun

    2018-02-15

    The use of polymer nanocomposites as novel materials for water remediation has emerged as a promising alternative for disinfection of bacteria contaminated water. Sodium alginate, a natural biopolymer has been investigated in this study by encapsulating antimicrobial zinc oxide nanoparticles supported bentonite. The confirmation of the alginate nanocomposites was done by use of TEM, SEM-EDS and XRD. The antimicrobial activity of the alginate nanocomposites was investigated by batch studies using surface water and synthetic bacteria contaminated water containing Staphylococcus aureus. The effect of nanocomposite amount and initial bacteria concentration has been studied. The inactivation results indicated that the nanocomposite effectively inactivated bacteria in both the synthetic and surface water. With an amount of 0.5 g of the nanocomposites, no bacteria was observed in the water after 70 min of contact time with initial bacteria concentration of 200 cfu/ml for synthetic water and within a min, no bacteria was observed in the water for surface water. It is worth noting that 200 cfu/ml is the bacteria concentration range in which environmental water is likely to contain. Therefore, the results of this study have indicated that the alginate nanocomposites can be deemed as a potential antimicrobial agent for water disinfection. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Use of reflectors to enhance the synergistic effects of solar heating and solar wavelengths to disinfect drinking water sources.

    PubMed

    Rijal, G K; Fujioka, R S

    2003-01-01

    Aluminum reflectors were added to solar units designed to inactivate faecal microorganisms (faecal coliform, E. coli, enterococci, FRNA coliphage, C. perfringens) in stream water and diluted sewage by the two mechanisms (solar heat, solar UV) known to inactivate microorganisms. During sunny conditions, solar units with and without reflectors inactivated E. coli to <1 CFU/100 ml to meet drinking water standards. Solar units with reflectors disinfected the water sooner by increasing the water temperature by 8-10 degrees C to 64-75 degrees C. However, FRNA coliphages were still detected in these samples, indicating that this treatment may not inactivate pathogenic human enteric viruses. During cloudy conditions, reflectors only increased the water temperature by 3-4 degrees C to a maximum of 43-49 degrees C and E. coli was not completely inactivated. Under sunny and cloudy conditions, the UV wavelengths of sunlight worked synergistically with increasing water temperatures and were able to disinfect microorganisms at temperatures (45-56 degrees C), which were not effective in inactivating microorganisms. Relative resistance to the solar disinfecting effects were C. perfringens > FRNA coliphages > enterococci > E. coli > faecal coliform.

  3. Attitudinal and Relational Factors Predicting the Use of Solar Water Disinfection: A Field Study in Nicaragua

    ERIC Educational Resources Information Center

    Altherr, Anne-Marie; Mosler, Hans-Joachim; Tobias, Robert; Butera, Fabrizio

    2008-01-01

    Solar water disinfection (SODIS) is an uncomplicated and cheap technology providing individuals with safe drinking water by exposing water-filled plastic bottles to sunlight for 6 hours to kill waterborne pathogens. Two communities were visited, and 81 families (40 SODIS users and 41 nonusers) were interviewed. The relationship between several…

  4. Medical effects of iodine disinfection products in spacecraft water

    NASA Technical Reports Server (NTRS)

    Sauer, Richard L.; Janik, Daniel S.; Thorstenson, Yvonne R.

    1987-01-01

    Various iodination products (IDPs), including iodinated and iodine-induced new compounds, will be present in the iodine-disinfected water that is expected to be used by crews on the NASA Space Station and on long duration missions. The metabolic intermediaries created by such a process may be more important to crew health than the parent IDPs, and reclamation and recycling may be expected to produce additional products. These medical effects may be expressed in crews as hypersensitivity, allergic, acute toxic, and chronic toxic reactions, as well as modifications of immune system response.

  5. PRELIMINARY SCREENING FOR THE POTENTIAL OF DRINKING WATER DISINFECTION BYPRODUCTS TO ALTER MALE REPRODUCTION

    EPA Science Inventory

    There is increasing epidemiologic interest in the role drinking water disinfection byproducts (DBPS) may play in adverse reproductive outcomes such as inability to conceive, spontaneous abortion, and low birth weight. nfortunately, few studies have attempted to determine whether ...

  6. Wetlands receiving water treated with coagulants improve water quality by removing dissolved organic carbon and disinfection byproduct precursors.

    PubMed

    Hansen, Angela M; Kraus, Tamara E C; Bachand, Sandra M; Horwath, William R; Bachand, Philip A M

    2018-05-01

    Constructed wetlands are used worldwide to improve water quality while also providing critical wetland habitat. However, wetlands have the potential to negatively impact drinking water quality by exporting dissolved organic carbon (DOC) that upon disinfection can form disinfection byproducts (DBPs) like trihalomethanes (THMs) and haloacetic acids (HAAs). We used a replicated field-scale study located on organic rich soils in California's Sacramento-San Joaquin Delta to test whether constructed flow-through wetlands which receive water high in DOC that is treated with either iron- or aluminum-based coagulants can improve water quality with respect to DBP formation. Coagulation alone removed DOC (66-77%) and THM (67-70%) precursors, and was even more effective at removing HAA precursors (77-90%). Passage of water through the wetlands increased DOC concentrations (1.5-7.5mgL -1 ), particularly during the warmer summer months, thereby reversing some of the benefits from coagulant addition. Despite this addition, water exiting the wetlands treated with coagulants had lower DOC and DBP precursor concentrations relative to untreated source water. Benefits of the coagulation-wetland systems were greatest during the winter months (approx. 50-70% reduction in DOC and DBP precursor concentrations) when inflow water DOC concentrations were higher and wetland DOC production was lower. Optical properties suggest DOC in this system is predominantly comprised of high molecular weight, aromatic compounds, likely derived from degraded peat soils. Published by Elsevier B.V.

  7. 40 CFR 141.64 - Maximum contaminant levels for disinfection byproducts.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... disinfection byproducts. 141.64 Section 141.64 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS National Primary Drinking... source water: Disinfection byproduct Best available technology Total trihalomethanes (TTHM) and...

  8. Demonstration tests of irrigation water disinfection with chlorine dioxide in open field cultivation of baby spinach.

    PubMed

    López-Gálvez, Francisco; Gil, Maria I; Meireles, Ana; Truchado, Pilar; Allende, Ana

    2018-06-01

    Treatments for the disinfection of irrigation water have to be evaluated by demonstration tests carried out under commercial settings taking into account not only their antimicrobial activity but also the potential phytotoxic effects on the crop. The consequences of the treatment of irrigation water with chlorine dioxide (ClO 2 ) used for sprinkler irrigation of baby spinach in two commercial agricultural fields was assessed. Residual ClO 2 levels at the sprinklers in the treated field were always below 1 mg L -1 . ClO 2 treatment provoked limited but statistically significant reductions in culturable Escherichia coli counts (0.2-0.3 log reductions), but not in the viable E. coli counts in water, suggesting the presence of viable but non-culturable cells (VBNC). Although disinfected irrigation water did not have an impact on the microbial loads of Enterobacteriaceae nor on the quality characteristics of baby spinach, it caused the accumulation of chlorates (up to 0.99 mg kg -1 in plants) and the reduction of the photosynthetic efficiency of baby spinach. Low concentrations of ClO 2 are effective in reducing the culturable E. coli present in irrigation water but it might induce the VBNC state. Presence of disinfection by-products and their accumulation in the crop must be considered to adjust doses in order to avoid crop damage and chemical safety risks. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  9. IDENTIFICATION OF CHLORINE DIOXIDE DRINKING WATER DISINFECTION BY-PRODUCTS FORMED AT HIGH BROMIDE LEVELS

    EPA Science Inventory

    Due to concern over the potential adverse health effects of trihalomethanes (THMs), haloacetic acids, and other chlorinated by-products in chlorinated drinking water, alternative disinfection methods are being explored. Chlorine dioxide is a popular alternative, with over 500 dri...

  10. Determination of several common disinfection by-products in frozen foods.

    PubMed

    Cardador, Maria Jose; Gallego, Mercedes

    2018-01-01

    Disinfected water and/or disinfectants are commonly used by the freezing industry in such processes as sanitising, washing, blanching, cooling and transporting the final product. For this reason, disinfection by-products (DBPs) can be expected in frozen foods. This study focused on the presence of DBPs in a wide variety of frozen vegetables, meats and fish. For this purpose, the 14 halogenated DBPs more prevalent in disinfected water were selected (four trihalomethanes, seven haloacetic acids, two haloacetonitriles and trichloronitromethane). Up to seven DBPs were found in vegetables, whereas only four DBPs were present in meats and fish, and at lower concentrations, since their contact with disinfected water is lower than in frozen vegetables. It is important to emphasise that trichloronitromethane (the most abundant nitrogenous DBP in disinfected water) was found for the first time in foods. Finally, it was concluded that the freezing process can keep the compounds stable longer than other preservation processes (viz. sanitising, canning) and, therefore, frozen foods present higher DBP concentrations than other food categories (minimally processed vegetables, or canned vegetables and meats).

  11. Effect of peracetic acid, ultraviolet radiation, nanofiltration-chlorine in the disinfection of a non conventional source of water (Tula Valley).

    PubMed

    Trujillo, J; Barrios, J A; Jimenez, B

    2008-01-01

    Water supply for human consumption requires certain quality that reduces health risks to consumers. In this sense, the process of disinfection plays an important role in the elimination of pathogenic microorganisms. Even though chlorination is the most applied process based on its effectiveness and cost, its application is being questioned considering the formation of disinfection by-products (DBPs). Therefore, alternative disinfectants are being evaluated and some treatment processes have been proposed to remove DBPs precursors (organic matter. This paper reports the results of disinfection of a non conventional source of water (aquifer recharged unintentionally with raw wastewater) with peracetic acid (PAA) and ultraviolet radiation (UV) as well as nanofiltration (NF) followed by chlorination to produce safe drinking water. The results showed that a dose of 2 mg/L PAA was needed to eliminate total and faecal coliforms. For UV light, a dose of 12.40 mWs/cm2 reduced total and faecal coliforms below the detection limit. On the other hand, chlorine demand of water before NF was 1.1-1.3 mg/L with a trihalomethane formation potential (THMFP) of 118.62 microg/L, in contrast with chlorination after NF where the demand was 0.5 mg/L and THMFP of 17.64 microg/L. The recommended scheme is nanofiltration + chlorination.

  12. The Occurrence and Toxicity of Disinfection Byproducts in European Drinking Waters in Relation with the HIWATE Epidemiology Study

    PubMed Central

    Jeong, Clara H.; Wagner, Elizabeth D.; Siebert, Vincent R.; Anduri, Sridevi; Richardson, Susan D.; Daiber, Eric J.; McKague, A. Bruce; Kogevinas, Manolis; Villanueva, Cristina M.; Goslan, Emma H.; Luo, Wentai; Isabelle, Lorne M.; Pankow, James F.; Grazuleviciene, Regina; Cordier, Sylvaine; Edwards, Susan C.; Righi, Elena; Nieuwenhuijsen, Mark J.; Plewa, Michael J.

    2012-01-01

    The HIWATE (Health Impacts of long-term exposure to disinfection byproducts in drinking WATEr) project was a systematic analysis that combined the epidemiology on adverse pregnancy outcomes and other health effects with long term exposure to low levels of drinking water disinfection byproducts (DBPs) in the European Union. The present study focused on the relationship of the occurrence and concentration of DBPs with in vitro mammalian cell toxicity. Eleven drinking water samples were collected from 5 European countries. Each sampling location corresponded with an epidemiological study for the HIWATE program. Over 90 DBPs were identified; the range in the number of DBPs and their levels reflected the diverse collection sites, different disinfection processes, and the different characteristics of the source waters. For each sampling site, chronic mammalian cell cytotoxicity correlated highly with the numbers of DBPs identified and the levels of DBP chemical classes. Although there was a clear difference in the genotoxic responses among the drinking waters, these data did not correlate as well with the chemical analyses. Thus, the agents responsible for the genomic DNA damage observed in the HIWATE samples may be due to unresolved associations of combinations of identified DBPs, unknown emerging DBPs that were not identified, or other toxic water contaminants. This study represents the first to integrate quantitative in vitro toxicological data with analytical chemistry and human epidemiologic outcomes for drinking water DBPs. PMID:22958121

  13. Genotoxicity of Disinfection By-products: Comparison to Carcinogenicity

    EPA Science Inventory

    Disinfection by-products (DBPs) can be formed when water is disinfected by various agents such as chlorine, ozone, or chloramines. Among the >600 DBPs identified in drinking water, 11 are regulated by the U.S. Environmental Protection Agency, and another ~70 DBPs that occur at s...

  14. ANIMAL MODELS FOR STUDYING MISCARRIAGE: ILLUSTRATION WITH STUDY OF DRINKING WATER DISINFECTION BY-PRODUCTS

    EPA Science Inventory

    Animal models for studying miscarriage: Illustration with study of drinking water disinfection by-products
    Authors & affiliations:
    Narotsky1, M.G. and S. Bielmeier Laffan2.
    1Reproductive Toxicology Division, NHEERL, ORD, U.S. Environmental Protection Agency, Research Tri...

  15. HALONITROMETHANE DRINKING WATER DISINFECTION BY-PRODUCTS: CHEMICAL CHARACTERIZATION AND MAMMALIAN CELL CYTOTOXICITY AND GENOTOXICITY

    EPA Science Inventory

    Halonitromethanes are drinking water disinfection by-products that have recently received a high priority for health effects research from the U.S. Environmental Protection Agency. Our purpose was to identify and synthesize where necessary the mixed halonitromethanes and to deter...

  16. 40 CFR 141.540 - Who has to develop a disinfection benchmark?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Enhanced Filtration and Disinfection-Systems Serving Fewer Than 10,000 People Disinfection Benchmark § 141.540 Who has to develop a... 40 Protection of Environment 22 2010-07-01 2010-07-01 false Who has to develop a disinfection...

  17. Do Iodine Contrast Media Compounds Used for Medical Imaging Contribute to the Formation of Iodinated Disinfection By-Products in Drinking Water?

    EPA Science Inventory

    Iodinated disinfection byproducts (DBPs) have recently gained attention due to their cyto- and genotoxicity and increased formation in drinking water treated with chloramine, which has become an increasingly popular disinfectant in the United States. One of these—iodoacetic acid...

  18. Genotoxicity of the disinfection by-products resulting from peracetic acid- or hypochlorite-disinfected sewage wastewater.

    PubMed

    Crebelli, R; Conti, L; Monarca, S; Feretti, D; Zerbini, I; Zani, C; Veschetti, E; Cutilli, D; Ottaviani, M

    2005-03-01

    Wastewater disinfection is routinely carried out to prevent the spread of human pathogens present in wastewater effluents. To this aim, chemical and physical treatments are applied to the effluents before their emission in water bodies. In this study, the influence of two widely used disinfectants, peracetic acid (PAA) and sodium hypochlorite (NaClO), on the formation of mutagenic by-products was investigated. Wastewater samples were collected before and after disinfection, in winter and in summer, at a pilot plant installed in a municipal wastewater-treatment plant. Samples were adsorbed using silica C18 cartridges and the concentrates were tested for mutagenicity in the Salmonella typhimurium reversion test with strains TA98 and TA100. Non-concentrated water samples were tested with two plant genotoxicity assays (the Allium cepa root anaphase aberration test and the Tradescantia/micronucleus test). Mutagenicity assays in bacteria and in Tradescantia showed borderline mutagenicity in some of the wastewater samples, independent of the disinfection procedure applied. Negative results were obtained in the A. cepa anaphase aberration test. These results indicate that, in the conditions applied, wastewater disinfection with PAA and NaClO does not lead to the formation of significant amounts of genotoxic by-products.

  19. Monohaloacetic acid drinking water disinfection by-products inhibit follicle growth and steroidogenesis in mouse ovarian antral follicles in vitro.

    PubMed

    Jeong, Clara H; Gao, Liying; Dettro, Tyler; Wagner, Elizabeth D; Ricke, William A; Plewa, Michael J; Flaws, Jodi A

    2016-07-01

    Water disinfection greatly reduced the incidence of waterborne diseases, but the reaction between disinfectants and natural organic matter in water leads to the formation of drinking water disinfection by-products (DBPs). DBPs have been shown to be toxic, but their effects on the ovary are not well defined. This study tested the hypothesis that monohalogenated DBPs (chloroacetic acid, CAA; bromoacetic acid, BAA; iodoacetic acid, IAA) inhibit antral follicle growth and steroidogenesis in mouse ovarian follicles. Antral follicles were isolated and cultured with either vehicle or DBPs (0.25-1.00mM of CAA; 2-15μM of BAA or IAA) for 48 and 96h. Follicle growth was measured every 24h and the media were analyzed for estradiol levels at 96h. Exposure to DBPs significantly inhibited antral follicle growth and reduced estradiol levels compared to controls. These data demonstrate that DBP exposure caused ovarian toxicity in vitro. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Monohaloacetic acid drinking water disinfection by-products inhibit follicle growth and steroidogenesis in mouse ovarian antral follicles in vitro

    PubMed Central

    Jeong, Clara H.; Gao, Liying; Dettro, Tyler; Wagner, Elizabeth D.; Ricke, William A.; Plewa, Michael J.; Flaws, Jodi A.

    2016-01-01

    Water disinfection greatly reduced the incidence of waterborne diseases, but the reaction between disinfectants and natural organic matter in water leads to the formation of drinking water disinfection by-products (DBPs). DBPs have been shown to be toxic, but their effects on the ovary are not well defined. This study tested the hypothesis that monohalogenated DBPs (chloroacetic acid, CAA; bromoacetic acid, BAA; iodoacetic acid, IAA) inhibit antral follicle growth and steroidogenesis in mouse ovarian follicles. Antral follicles were isolated and cultured with either vehicle or DBPs (0.25–1.00 mM of CAA; 2–15 µM of BAA or IAA) for 48 and 96 h. Follicle growth was measured every 24 h and the media were analyzed for estradiol levels at 96 h. Exposure to DBPs significantly inhibited antral follicle growth and reduced estradiol levels compared to controls. These data demonstrate that DBP exposure caused ovarian toxicity in vitro. PMID:27151372

  1. Impulse powerful UV-radiation source pumped by the sublight ionization waves for the bacteriological disinfection of water

    NASA Astrophysics Data System (ADS)

    Filiouguine, Igor V.; Kostiouchenko, S. V.; Koudryavtsev, N. N.; Vasilyak, Leonid M.; Yakimenko, A. V.

    1993-11-01

    The bacteriological disinfective action of UV-radiation is well known. The pioneer work on UV-radiation used for bacteriological disinfection of waste water was made in 1910. Because of the high cost and low living time of the UV-radiation sources, the alternative technique for waste water purification by chlorine introducing was spread out. During the second stage of the UV purification development, beginning in approximately 1970, the interest for bacteriological cleaning of water, increased again. Two reasons were responsible for this event: first, the significant improvement of technology and design of UV-bacteriological purificators, and second, recognition of the serious danger of chlorine compounds introduced into water under purification because of the toxicity of these compounds. Further investigations gave excellent results in the creation and industrial applications of UV- bacteriological purificators. Now we can see a rapid development of industrial technology in UV-purification of drinking and waste waters.

  2. TOXICOLOGIC AND CHEMICAL EVALUATION OF ALTERNATIVE DISINFECTION TREATMENT SCENARIOS

    EPA Science Inventory

    More than 500 disinfecting byproducts have been identified. They result from the reaction of the disinfectants with the natural organic matter present in source waters. The concentrations and bromo/chloro speciation of these disinfection byproducts (DBPs) are influenced by source...

  3. MUTAGENICITY IN SALMONELLA OF HALONITROMETHANES: A RECENTLY RECOGNIZED CLASS OF DISINFECTION BY-PRODUCTS IN DRINKING WATER

    EPA Science Inventory

    Halonitromethanes (HNMs) are a recently identified class of disinfection by-products in drinking water. They include chloronitromethane (CHN), dichloronitromethane (DCNM), trichloronitromethane (TCNM), bromonitromethane (BNM), dibromonitromethane (DBNM), tribromonitromethane (TBN...

  4. Disinfection of the Water Borne Pathogens Escherichia coli and Staphylococcus aureus by Solar Photocatalysis Using Sonochemically Synthesized Reusable Ag@ZnO Core-Shell Nanoparticles.

    PubMed

    Das, Sourav; Ranjana, Neha; Misra, Ananyo Jyoti; Suar, Mrutyunjay; Mishra, Amrita; Tamhankar, Ashok J; Lundborg, Cecilia Stålsby; Tripathy, Suraj K

    2017-07-10

    Water borne pathogens present a threat to human health and their disinfection from water poses a challenge, prompting the search for newer methods and newer materials. Disinfection of the Gram-negative bacterium Escherichia coli and the Gram-positive coccal bacterium Staphylococcus aureus in an aqueous matrix was achieved within 60 and 90 min, respectively, at 35 °C using solar-photocatalysis mediated by sonochemically synthesized Ag@ZnO core-shell nanoparticles. The efficiency of the process increased with the increase in temperature and at 55 °C the disinfection for the two bacteria could be achieved in 45 and 60 min, respectively. A new ultrasound-assisted chemical precipitation technique was used for the synthesis of Ag@ZnO core-shell nanoparticles. The characteristics of the synthesized material were established using physical techniques. The material remained stable even at 400 °C. Disinfection efficiency of the Ag@ZnO core-shell nanoparticles was confirmed in the case of real world samples of pond, river, municipal tap water and was found to be better than that of pure ZnO and TiO₂ (Degussa P25). When the nanoparticle- based catalyst was recycled and reused for subsequent disinfection experiments, its efficiency did not change remarkably, even after three cycles. The sonochemically synthesized Ag@ZnO core-shell nanoparticles thus have a good potential for application in solar photocatalytic disinfection of water borne pathogens.

  5. Comparison of media for enumeration of coliform bacteria and Escherichia coli in non-disinfected water.

    PubMed

    Pitkänen, Tarja; Paakkari, Piia; Miettinen, Ilkka T; Heinonen-Tanski, Helvi; Paulin, Lars; Hänninen, Marja-Liisa

    2007-03-01

    In this work alternative media for detection and enumeration of E. coli and coliform bacteria were compared to the reference method ISO 9308-1 (LTTC) using non-disinfected water samples with background flora. The alternative media included LES Endo agar medium (LES Endo), Colilert-18 with 51-well Quanti-tray (Colilert), Chromocult Coliform agar (CC), Harlequin E. coli/Coliform medium (HECM) and Chromogenic Escherichia coli/Coliform medium (CECM). A total of 110 samples of groundwater, bathing water and spiked water was used. Our results revealed that confirmation of coliform bacteria counts is necessary, not only on lactose-based LTTC and LES Endo media, but also on the chromogenic agar media tested, due to the growth of oxidase positive colonies. LTTC and CC media also allowed the growth of some morphologically typical coliform colonies containing gram-positive bacteria. The recovery of coliform bacteria was lower on LES Endo than on LTTC. In most cases Colilert, CC, HECM and CECM gave higher coliform counts than LTTC. The use of the LTTC medium led to higher E. coli counts than obtained with any of the alternative mediums. There are three explanations for this: (1) high sensitivity of LTTC, (2) false positives on LTTC or (3) false negatives especially with Colilert, but also with chromogenic agar media. Although LTTC was found to be a very sensitive medium, the high degree of background growth of non-disinfected waters disturbed substantially the use of it. In conclusion, our results suggest that Colilert, CC and CECM are potential alternative media for detection of coliform bacteria and E. coli from non-disinfected water.

  6. Evaluation of Filtration and UV Disinfection for Inactivation of Viruses in Non-Community Water Systems in Minnesota

    EPA Science Inventory

    This study evaluated filtration and disinfection processes for removal and inactivation of pathogens in non-community water systems (NCWS) in two surface water supplies. Pretreatment systems included 1) pressure sand filtration, and 2) granular activated carbon adsorption, and 3...

  7. EPIDEMIOLOGIC STUDIES OF DISINFECTANTS AND DISINFECTANT BY-PRODUCTS

    EPA Science Inventory

    This article provides a review of the epidemiologic evidence for human health effects that may be associated with the disinfection of drinking water. An epidemiologic study attempts to link human health effects with exposure to a specific agent (e.g., DBCM), agents (e.g., THMs or...

  8. New chlorinated amphetamine-type-stimulants disinfection-by-products formed during drinking water treatment.

    PubMed

    Huerta-Fontela, Maria; Pineda, Oriol; Ventura, Francesc; Galceran, Maria Teresa

    2012-06-15

    Previous studies have demonstrated high removal rates of amphetamine-type-stimulants (ATSs) through conventional drinking water treatments; however the behaviour of these compounds through disinfection steps and their transformation into disinfection-by-products (DBPs) is still unknown. In this work, for the first time, the reactivity of some ATSs such as amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine (MDA), 3,4-methylenedioxymethamphetamine (MDMA) and 3,4-methylenedioxyethylamphetamine (MDEA) with chlorine has been investigated under simulated and real drinking water treatment conditions in order to evaluate their ability to give rise to transformation products. Two new DBPs from these illicit drugs have been found. A common chlorinated-by-product (3-chlorobenzo)-1,3-dioxole, was identified for both MDA and MDEA while for MDMA, 3-chlorocatechol was found. The presence of these DBPs in water samples collected through drinking water treatment was studied in order to evaluate their formation under real conditions. Both compounds were generated through treatment from raw river water samples containing ATSs at concentration levels ranging from 1 to 15 ng/L for MDA and from 2.3 to 78 ng/L for MDMA. One of them, (3-chlorobenzo)-1,3-dioxole, found after the first chlorination step, was eliminated after ozone and GAC treatment while the MDMA DBP mainly generated after the postchlorination step, showed to be recalcitrant and it was found in final treated waters at concentrations ranging from 0.5 to 5.8 ng/L. Copyright © 2012 Elsevier Ltd. All rights reserved.

  9. UV disinfection for reuse applications in North America.

    PubMed

    Sakamoto, G; Schwartzel, D; Tomowich, D

    2001-01-01

    In an effort to conserve and protect limited water resources, the States of Florida and California have actively promoted wastewater reclamation and have implemented comprehensive regulations covering a range of reuse applications. Florida has a semi-tropical climate with heavy summer rains that are lost due to run off and evaporation. Much of California is arid and suffers periodic droughts, low annual rainfall and depleted ground water supplies. The high population density combined with heavy irrigation demands has depleted ground water supplies resulting in salt-water intrusion. During the past decade, Florida reuse sites have increased dramatically from 118 to 444 plants representing a total flow capacity of 826 MGD. California presently has over 250 plants producing 1 BGD with a projected increase of 160 sites over the next 20 years. To prevent the transmission of waterborne diseases, disinfection of reclaimed water is controlled by stringent regulations. Many states regulate wastewater treatment processes, nutrient removal, final effluent quality and disinfection criteria based upon the specific reuse application. As a rule, the resulting effluents have low turbidity and suspended solids. For such effluents, UV technology can economically achieve the most stringent disinfection targets that are required by the States of California and Florida for restricted and unrestricted reuse. This paper compares UV disinfection for wastewater reuse sites in California and Florida and discusses the effect of effluent quality on UV disinfection.

  10. Peracetic acid for secondary effluent disinfection: a comprehensive performance assessment.

    PubMed

    Antonelli, M; Turolla, A; Mezzanotte, V; Nurizzo, C

    2013-01-01

    The paper is a review of previous research on secondary effluent disinfection by peracetic acid (PAA) integrated with new data about the effect of a preliminary flash-mixing step. The process was studied at bench and pilot scale to assess its performance for discharge in surface water and agricultural reuse (target microorganisms: Escherichia coli and faecal coliform bacteria). The purposes of the research were: (1) determining PAA decay and disinfection kinetics as a function of operating parameters, (2) evaluating PAA suitability as a disinfectant, (3) assessing long-term disinfection efficiency, (4) investigating disinfected effluent biological toxicity on some aquatic indicator organisms (Vibrio fischeri, Daphnia magna and Selenastrum capricornutum), (5) comparing PAA with conventional disinfectants (sodium hypochlorite, UV irradiation). PAA disinfection was capable of complying with Italian regulations on reuse (10 CFU/100 mL for E. coli) and was competitive with benchmarks. No regrowth phenomena were observed, as long as needed for agricultural reuse (29 h after disinfection), even at negligible concentrations of residual disinfectant. The toxic effect of PAA on the aquatic environment was due to the residual disinfectant in the water, rather than to chemical modification of the effluent.

  11. Reproductive toxicity of a mixture of regulated drinking-water disinfection by-products in a multigenerational rat bioassay

    EPA Science Inventory

    BACKGROUND:Trihalomethanes (THMs) and haloaretic acids (HAAs) are regulated disinfection by-products (DBPs); their joint reproductive toxicity in drinking water is unknown.OBJECTIVE: We aimed to evaluate a drinking water mixture of the four regulated THMs and five regulated HAAs ...

  12. Shift in the Microbial Ecology of a Hospital Hot Water System following the Introduction of an On-Site Monochloramine Disinfection System

    PubMed Central

    Baron, Julianne L.; Vikram, Amit; Duda, Scott; Stout, Janet E.; Bibby, Kyle

    2014-01-01

    Drinking water distribution systems, including premise plumbing, contain a diverse microbiological community that may include opportunistic pathogens. On-site supplemental disinfection systems have been proposed as a control method for opportunistic pathogens in premise plumbing. The majority of on-site disinfection systems to date have been installed in hospitals due to the high concentration of opportunistic pathogen susceptible occupants. The installation of on-site supplemental disinfection systems in hospitals allows for evaluation of the impact of on-site disinfection systems on drinking water system microbial ecology prior to widespread application. This study evaluated the impact of supplemental monochloramine on the microbial ecology of a hospital’s hot water system. Samples were taken three months and immediately prior to monochloramine treatment and monthly for the first six months of treatment, and all samples were subjected to high throughput Illumina 16S rRNA region sequencing. The microbial community composition of monochloramine treated samples was dramatically different than the baseline months. There was an immediate shift towards decreased relative abundance of Betaproteobacteria, and increased relative abundance of Firmicutes, Alphaproteobacteria, Gammaproteobacteria, Cyanobacteria and Actinobacteria. Following treatment, microbial populations grouped by sampling location rather than sampling time. Over the course of treatment the relative abundance of certain genera containing opportunistic pathogens and genera containing denitrifying bacteria increased. The results demonstrate the driving influence of supplemental disinfection on premise plumbing microbial ecology and suggest the value of further investigation into the overall effects of premise plumbing disinfection strategies on microbial ecology and not solely specific target microorganisms. PMID:25033448

  13. Shift in the microbial ecology of a hospital hot water system following the introduction of an on-site monochloramine disinfection system.

    PubMed

    Baron, Julianne L; Vikram, Amit; Duda, Scott; Stout, Janet E; Bibby, Kyle

    2014-01-01

    Drinking water distribution systems, including premise plumbing, contain a diverse microbiological community that may include opportunistic pathogens. On-site supplemental disinfection systems have been proposed as a control method for opportunistic pathogens in premise plumbing. The majority of on-site disinfection systems to date have been installed in hospitals due to the high concentration of opportunistic pathogen susceptible occupants. The installation of on-site supplemental disinfection systems in hospitals allows for evaluation of the impact of on-site disinfection systems on drinking water system microbial ecology prior to widespread application. This study evaluated the impact of supplemental monochloramine on the microbial ecology of a hospital's hot water system. Samples were taken three months and immediately prior to monochloramine treatment and monthly for the first six months of treatment, and all samples were subjected to high throughput Illumina 16S rRNA region sequencing. The microbial community composition of monochloramine treated samples was dramatically different than the baseline months. There was an immediate shift towards decreased relative abundance of Betaproteobacteria, and increased relative abundance of Firmicutes, Alphaproteobacteria, Gammaproteobacteria, Cyanobacteria and Actinobacteria. Following treatment, microbial populations grouped by sampling location rather than sampling time. Over the course of treatment the relative abundance of certain genera containing opportunistic pathogens and genera containing denitrifying bacteria increased. The results demonstrate the driving influence of supplemental disinfection on premise plumbing microbial ecology and suggest the value of further investigation into the overall effects of premise plumbing disinfection strategies on microbial ecology and not solely specific target microorganisms.

  14. Use of household bleach for emergency disinfection of drinking water.

    PubMed

    Elmaksoud, Sherif Abd; Patel, Nikita; Maxwell, Sherri L; Sifuentes, Laura Y; Gerba, Charles P

    2014-05-01

    Household bleach is typically used as a disinfectant for water in times of emergencies and by those engaging in recreational activities such as camping or rafting. The Centers for Disease Control and Prevention recommend a concentration of free chlorine of 1 mg/L for 30 minutes, or about 0.75 mL (1/8 teaspoon) of household bleach per gallon of water. The goal of the study described in this article was to assess two household bleach products to kill waterborne bacteria and viruses using the test procedures in the U.S. Environmental Protection Agency's Guide Standard and Protocol for Testing Microbiological Purifiers. Bleach was found to meet these requirements in waters of low turbidity and organic matter. While the test bacterium was reduced by six logs in high turbid and organic-laden waters, the test viruses were reduced only by one-half to one log. In such waters greater chlorine doses or contact times are needed to achieve greater reduction of viruses.

  15. Microbial contamination and disinfection methods of pacifiers.

    PubMed

    Nelson-Filho, Paulo; Louvain, Márcia Costa; Macari, Soraia; Lucisano, Marília Pacífico; Silva, Raquel Assed Bezerra da; Queiroz, Alexandra Mussolino de; Gaton-Hernández, Patrícia; Silva, Léa Assed Bezerra da

    2015-10-01

    To evaluate the microbial contamination of pacifiers by Mutans Streptococci(MS) and the efficacy of different methods for their disinfection. Twenty-eight children were assigned to a 4-stage changeover system with a 1-week interval. In each stage, children received a new pacifier and the parents were instructed to maintain their normal habits for 1 week. After this time, the pacifiers were subjected to the following 4 disinfection methods: spraying with 0.12% chlorhexidine solution, Brushtox or sterile tap water, and immersion in boiling tap water for 15 minutes. Microbiological culture for MS and Scanning Electron Microscopy (SEM) were performed. The results were analyzed statistically by Friedman's non-parametric test (a=0.05). The 0.12% chlorhexidine spray was statistically similar to the boiling water (p>0.05) and more effective than the Brushtox spray and control (p<0.05). The analysis of SEM showed the formation of a cariogenic biofilm in all groups with positive culture. Pacifiers become contaminated by MS after their use by children and should be disinfected routinely. Spraying with a 0.12% chlorhexidine solution and immersion in boiling water promoted better disinfection of the pacifiers compared with a commercial antiseptic toothbrush cleanser (Brushtox).

  16. Formation and Occurrence of Disinfection By-Products

    EPA Science Inventory

    Disinfection by-products (DBPs) are formed when disinfectants such as chlorine, ozone, chlorine dioxide, or chloramines react with naturally occurring organic matter, anthropogenic contaminants, bromide, and iodide during the production of drinking water. There is concern about D...

  17. Occurrence of carboxylic acids in different steps of two drinking-water treatment plants using different disinfectants.

    PubMed

    Jurado-Sánchez, Beatriz; Ballesteros, Evaristo; Gallego, Mercedes

    2014-03-15

    The occurrence of 35 aliphatic and aromatic carboxylic acids within two full scale drinking-water treatment plants was evaluated for the first time in this research. At the intake of each plant (raw water), the occurrence of carboxylic acids varied according to the quality of the water source although in both cases 13 acids were detected at average concentrations of 6.9 and 4.7 μg/L (in winter). In the following steps in each treatment plant, the concentration patterns of these compounds differed depending on the type of disinfectant applied. Thus, after disinfection by chloramination, the levels of the acids remained almost constant (average concentration, 6.3 μg/L) and four new acids were formed (butyric, 2-methylbutyric, 3-hydroxybenzoic and 2-nitrobenzoic) at low levels (1.1-5 μg/L). When ozonation/chlorination was used, the total concentration of the carboxylic acids in the raw water sample (4.7 μg/L) increased up to 6 times (average concentration, 26.3 μg/L) after disinfection and 6 new acids (mainly aromatic) were produced at high levels (3.5-100 μg/L). Seasonal variations of the carboxylic acids under study showed that in both plants, maximum levels of all the analytes were reached in the coldest months (autumn and winter), aromatic acids only being found in those seasons. Copyright © 2013 Elsevier Ltd. All rights reserved.

  18. Numerical study of the effects of lamp configuration and reactor wall roughness in an open channel water disinfection UV reactor.

    PubMed

    Sultan, Tipu

    2016-07-01

    This article describes the assessment of a numerical procedure used to determine the UV lamp configuration and surface roughness effects on an open channel water disinfection UV reactor. The performance of the open channel water disinfection UV reactor was numerically analyzed on the basis of the performance indictor reduction equivalent dose (RED). The RED values were calculated as a function of the Reynolds number to monitor the performance. The flow through the open channel UV reactor was modelled using a k-ε model with scalable wall function, a discrete ordinate (DO) model for fluence rate calculation, a volume of fluid (VOF) model to locate the unknown free surface, a discrete phase model (DPM) to track the pathogen transport, and a modified law of the wall to incorporate the reactor wall roughness effects. The performance analysis was carried out using commercial CFD software (ANSYS Fluent 15.0). Four case studies were analyzed based on open channel UV reactor type (horizontal and vertical) and lamp configuration (parallel and staggered). The results show that lamp configuration can play an important role in the performance of an open channel water disinfection UV reactor. The effects of the reactor wall roughness were Reynolds number dependent. The proposed methodology is useful for performance optimization of an open channel water disinfection UV reactor. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. IDENTIFICATION OF NEW DRINKING WATER DISINFECTION BY-PRODUCTS FROM OZONE, CHLORINE DIOXIDE, CHLORAMINE, AND CHLORINE

    EPA Science Inventory

    Due to concern over the potential adverse health effects of trihalomethanes (THMs) and other chlorinated by-products in chlorinated drinking water, alternative disinfection methods are being explored. Ozone, chlorine dioxide, and chloramine are currently popular alternatives to ...

  20. Virus disinfection in water by biogenic silver immobilized in polyvinylidene fluoride membranes.

    PubMed

    De Gusseme, Bart; Hennebel, Tom; Christiaens, Eline; Saveyn, Hans; Verbeken, Kim; Fitts, Jeffrey P; Boon, Nico; Verstraete, Willy

    2011-02-01

    The development of innovative water disinfection strategies is of utmost importance to prevent outbreaks of waterborne diseases related to poor treatment of (drinking) water. Recently, the association of silver nanoparticles with the bacterial cell surface of Lactobacillus fermentum (referred to as biogenic silver or bio-Ag(0)) has been reported to exhibit antiviral properties. The microscale bacterial carrier matrix serves as a scaffold for Ag(0) particles, preventing aggregation during encapsulation. In this study, bio-Ag(0) was immobilized in different microporous PVDF membranes using two different pre-treatments of bio-Ag(0) and the immersion-precipitation method. Inactivation of UZ1 bacteriophages using these membranes was successfully demonstrated and was most probably related to the slow release of Ag(+) from the membranes. At least a 3.4 log decrease of viruses was achieved by application of a membrane containing 2500 mg bio-Ag(0)(powder) m(-2) in a submerged plate membrane reactor operated at a flux of 3.1 L m(-2) h(-1). Upon startup, the silver concentration in the effluent initially increased to 271 μg L(-1) but after filtration of 31 L m(-2), the concentration approached the drinking water limit ( = 100 μg L(-1)). A virus decline of more than 3 log was achieved at a membrane flux of 75 L m(-2) h(-1), showing the potential of this membrane technology for water disinfection on small scale. © 2010 Elsevier Ltd. All rights reserved.

  1. Cyto- and genotoxic profile of groundwater used as drinking water supply before and after disinfection.

    PubMed

    Pellacani, C; Cassoni, F; Bocchi, C; Martino, A; Pinto, G; Fontana, F; Furlini, M; Buschini, A

    2016-12-01

    The assessment of the toxicological properties of raw groundwater may be useful to predict the type and quality of tap water. Contaminants in groundwater are known to be able to affect the disinfection process, resulting in the formation of substances that are cytotoxic and/or genotoxic. Though the European directive (98/83/EC, which establishes maximum levels for contaminants in raw water (RW)) provides threshold levels for acute exposure to toxic compounds, the law does not take into account chronic exposure at low doses of pollutants present in complex mixture. The purpose of this study was to evaluate the cyto- and genotoxic load in the groundwater of two water treatment plants in Northern Italy. Water samples induced cytotoxic effects, mainly observed when human cells were treated with RW. Moreover, results indicated that the disinfection process reduced cell toxicity, independent of the biocidal used. The induction of genotoxic effects was found, in particular, when the micronucleus assay was carried out on raw groundwater. These results suggest that it is important to include bio-toxicological assays as additional parameters in water quality monitoring programs, as their use would allow the evaluation of the potential risk of groundwater for humans.

  2. Effect of iodine disinfection products on higher plants

    NASA Technical Reports Server (NTRS)

    Janik, D.; Macler, B.; Macelroy, R. D.; Thorstenson, Y.; Sauer, R.

    1989-01-01

    Iodine is used to disinfect potable water on United States spacecraft. Iodinated potable water will likely be used to grow plants in space. Little is known about the effects of iodine disinfection products on plants. Seeds of select higher plants were germinated in water iodinated using the Shuttle Microbial Check Valve, and water to which measured amounts of iodine was added. Percent germination was decreased in seeds of most species germinated in iodinated water. Beans were most affected. Germination rates, determined from germination half-times, were decreased for beans germinated in iodinated water, and water to which iodide was added. Development was retarded and rootlets were conspicuously absent in bean and several other plant species germinated in iodinated water. Iodide alone did not elicit these responses. Clearly iodine disinfection products can affect higher plants. These effects must be carefully considered for plant experimentation and cultivation in space, and in design and testing of closed environmental life support systems.

  3. APPLICATION OF SOLID PHASE MICROEXTRACTION GC/MS TO THE CHARACTERIZATION OF HYDROPHILIC DISINFECTION BY-PRODUCTS IN WATER

    EPA Science Inventory

    The U.S. Environmental Protection Agency has given high priority to research aimed at developing methods to extract hydrophilic disinfection by-products (DBPs) from drinking water. Public water supplies are treated with a variety of chemicals aimed at reducing or eliminating inf...

  4. [Testing the efficacy of disinfectants during drinking water treatment. A new experimental set-up at the German EPA (Umweltbundesamt - UBA)].

    PubMed

    Grützmacher, G; Bartel, H; Althoff, H W; Clemen, S

    2007-03-01

    A set-up for experiments in the flow-through mode was constructed in order to test the efficacy of substances used for disinfecting water during drinking water treatment. A flow-through mode - in contrast to experiments under stationary conditions (so-called batch experiments) - was chosen, because this experimental design allows experiments to be carried out under constant conditions for an extended time (up to one week) and because efficacy testing is possible repeatedly, simultaneously and under exactly the same conditions for short (about 0.5 min) and also longer (about 47 min) contact times. With this experimental design the effect of biofilms along the inner pipe surfaces can be included in the observations. The construction of the experimental set-up is based on experience with laboratory flow-through systems that were installed by the UBA's drinking water department (formerly Institute for Water-, Soil- and Air Hygiene (WaBoLu) Institute) for testing disinfection with chlorine. In the first step, a test pipe for the simulation of a water works situation was installed. Water of different qualities can be mixed in large volumes beforehand so that the experimental procedure can be run with constant water quality for a minimum of one week. The kinetics of the disinfection reaction can be observed by extracting samples from eight sampling ports situated along the test pipe. In order to assign exact residence times to each of the sampling ports, tracer experiments were performed prior to testing disinfectant efficacy. This paper gives the technical details of the experimental set-up and presents the results of the tracer experiments to provide an introduction with respect to its potential.

  5. Haloacetic Acid Water Disinfection Byproducts Affect Pyruvate Dehydrogenase Activity and Disrupt Cellular Metabolism.

    PubMed

    Dad, Azra; Jeong, Clara H; Wagner, Elizabeth D; Plewa, Michael J

    2018-02-06

    The disinfection of drinking water has been a major public health achievement. However, haloacetic acids (HAAs), generated as byproducts of water disinfection, are cytotoxic, genotoxic, mutagenic, carcinogenic, and teratogenic. Previous studies of monoHAA-induced genotoxicity and cell stress demonstrated that the toxicity was due to inhibition of glyceraldehyde-3-phosphate dehydrogenase (GAPDH), leading to disruption of cellular metabolism and energy homeostasis. DiHAAs and triHAAs are also produced during water disinfection, and whether they share mechanisms of action with monoHAAs is unknown. In this study, we evaluated the effects of mono-, di-, and tri-HAAs on cellular GAPDH enzyme kinetics, cellular ATP levels, and pyruvate dehydrogenase complex (PDC) activity. Here, treatments conducted in Chinese hamster ovary (CHO) cells revealed differences among mono-, di-, and triHAAs in their molecular targets. The monoHAAs, iodoacetic acid and bromoacetic acid, were the strongest inhibitors of GAPDH and greatly reduced cellular ATP levels. Chloroacetic acid, diHAAs, and triHAAs were weaker inhibitors of GAPDH and some increased the levels of cellular ATP. HAAs also affected PDC activity, with most HAAs activating PDC. The primary finding of this work is that mono- versus multi-HAAs address different molecular targets, and the results are generally consistent with a model in which monoHAAs activate the PDC through GAPDH inhibition-mediated disruption in cellular metabolites, including altering ATP-to-ADP and NADH-to-NAD ratios. The monoHAA-mediated reduction in cellular metabolites results in accelerated PDC activity by way of metabolite-ratio-dependent PDC regulation. DiHAAs and triHAAs are weaker inhibitors of GAPDH, but many also increase cellular ATP levels, and we suggest that they increase PDC activity by inhibiting pyruvate dehydrogenase kinase.

  6. A novel gravity-driven nanofibrous membrane for point-of-use water disinfection: polydopamine-induced in situ silver incorporation.

    PubMed

    Wang, Jianqiang; Wu, Yichao; Yang, Zhe; Guo, Hao; Cao, Bin; Tang, Chuyang Y

    2017-05-24

    We report a facile method for preparing silver-loaded membranes for point-of-use disinfection and disaster relief applications. A bio-inspired material, polydopamine, was coated onto a highly porous nanofibrous polyacrylonitrile substrate. We then take advantage of the redox properties of polydopamine to form silver nanoparticles in situ. These nanoparticles were uniformly distributed on the surface of nanofibers with no apparent agglomeration at a silver loading up to 4.36 wt.% (cPAN-Ag1.5). The silver-incorporated membrane cPAN-Ag1.5 achieved a high pure water flux of 130 Lm -2 h -1 at 10-cm water head, demonstrating the feasibility of energy-efficient gravity-driven filtration and eliminating the need for electrical power. The strong anti-bacterial activity and high physical rejection of the membrane led to an excellent disinfection power, with no viable bacterial cells detected in its permeate water. The membrane exhibited >7 log reduction for E. coli and >6 log reduction for B. subtilis. The strategy reported here provides an efficient and green route to synthesize point-of-use membranes. Combining their excellent permeability and disinfection effectiveness, these membranes offer an ideal solution to water supply in disaster-affected areas.

  7. OCCURRENCE OF IODO-ACID AND IODO-THM DISINFECTION BY-PRODUCTS IN CHLORAMINATED DRINKING WATER

    EPA Science Inventory

    Iodo-acids were recently identified for the first time as DBPs in drinking water disinfected with chloramines. The iodo-acids identified included iodoacetic acid (IAA), bromoiodoacetic acid, (E)-3-bromo-3-iodo-propenoic acid, (Z)-3-bromo-3-iodo-propenoic acid, and (E)-2-iodo-3...

  8. Disinfection of the Water Borne Pathogens Escherichia coli and Staphylococcus aureus by Solar Photocatalysis Using Sonochemically Synthesized Reusable Ag@ZnO Core-Shell Nanoparticles

    PubMed Central

    Das, Sourav; Ranjana, Neha; Misra, Ananyo Jyoti; Suar, Mrutyunjay; Mishra, Amrita; Tripathy, Suraj K.

    2017-01-01

    Water borne pathogens present a threat to human health and their disinfection from water poses a challenge, prompting the search for newer methods and newer materials. Disinfection of the Gram-negative bacterium Escherichia coli and the Gram-positive coccal bacterium Staphylococcus aureus in an aqueous matrix was achieved within 60 and 90 min, respectively, at 35 °C using solar-photocatalysis mediated by sonochemically synthesized Ag@ZnO core-shell nanoparticles. The efficiency of the process increased with the increase in temperature and at 55 °C the disinfection for the two bacteria could be achieved in 45 and 60 min, respectively. A new ultrasound-assisted chemical precipitation technique was used for the synthesis of Ag@ZnO core-shell nanoparticles. The characteristics of the synthesized material were established using physical techniques. The material remained stable even at 400 °C. Disinfection efficiency of the Ag@ZnO core-shell nanoparticles was confirmed in the case of real world samples of pond, river, municipal tap water and was found to be better than that of pure ZnO and TiO2 (Degussa P25). When the nanoparticle- based catalyst was recycled and reused for subsequent disinfection experiments, its efficiency did not change remarkably, even after three cycles. The sonochemically synthesized Ag@ZnO core-shell nanoparticles thus have a good potential for application in solar photocatalytic disinfection of water borne pathogens. PMID:28698514

  9. Evaluation of Disinfection Byproducts formed from the Chlorination of Lyophilized and Reconstituted NOM Concentrate from a Drinking Water Source

    EPA Science Inventory

    Drinking water treatment and disinfection byproduct (DBP) research can be complicated by difficulties in shipping large water quantities and NOM geographical and temporal variability. Access to a drinking water representative, shelf-stable, concentrated NOM source would solve th...

  10. POWDERED ACTIVATED CARBON FROM NORTH DAKOTA LIGNITE: AN OPTION FOR DISINFECTION BY-PRODUCT CONTROL IN WATER TREATMENT PLANTS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Daniel J. Stepan; Thomas A. Moe; Melanie D. Hetland

    New federal drinking water regulations have been promulgated to restrict the levels of disinfection by-products (DBPs) in finished public water supplies. DBPs are suspected carcinogens and are formed when organic material is partially oxidized by disinfectants commonly used in the water treatment industry. Additional federal mandates are expected in the near future that will further affect public water suppliers with respect to DBPs. Powdered activated carbon (PAC) has traditionally been used by the water treatment industry for the removal of compounds contributing to taste and odor problems. PAC also has the potential to remove naturally occurring organic matter (NOM) frommore » raw waters prior to disinfection, thus controlling the formation of regulated DBPs. Many small water systems are currently using PAC for taste and odor control and have the potential to use PAC for controlling DBPs. This project, a cooperative effort between the Energy & Environmental Research Center (EERC), the Grand Forks Water Treatment Plant, and the University of North Dakota Department of Civil Engineering, consists of several interrelated tasks. The objective of the research was to evaluate a cost-effective PAC produced from North Dakota lignite for removing NOM from water and reducing trihalomethane formation potential. The research approach was to develop a statistically valid testing protocol that can be used to compare dose-response relationships between North Dakota lignite-derived PAC and commercially available PAC products. A statistical analysis was performed to determine whether significant correlations exist between operating conditions, water properties, PAC properties, and dose-response behavior. Pertinent physical and chemical properties were also measured for each of the waters and each of the PACs.« less

  11. Bacterial community changes in copper and PEX drinking water pipeline biofilms under extra disinfection and magnetic water treatment.

    PubMed

    Inkinen, J; Jayaprakash, B; Ahonen, M; Pitkänen, T; Mäkinen, R; Pursiainen, A; Santo Domingo, J W; Salonen, H; Elk, M; Keinänen-Toivola, M M

    2018-02-01

    To study the stability of biofilms and water quality in pilot scale drinking water copper and PEX pipes in changing conditions (extra disinfection, magnetic water treatment, MWT). Next-generation sequencing (NGS) of 16S ribosomal RNA genes (rDNA) to describe total bacterial community and ribosomal RNA (rRNA) to describe active bacterial members in addition to traditional microbiological methods were applied. Biofilms from control copper and PEX pipes shared same most abundant bacteria (Methylobacterium spp., Sphingomonas spp., Zymomonas spp.) and average species diversities (Shannon 3·8-4·2) in rDNA and rRNA libraries, whereas few of the taxa differed by their abundance such as lower total Mycobacterium spp. occurrence in copper (<0·02%) to PEX (<0·2%) pipes. Extra disinfection (total chlorine increase from c. 0·5 to 1 mg l -1 ) affected total and active population in biofilms seen as decrease in many bacterial species and diversity (Shannon 2·7, P < 0·01, rRNA) and increase in Sphingomonas spp. as compared to control samples. Furthermore, extra-disinfected copper and PEX samples formed separate clusters in unweighted non-metric multidimensional scaling plot (rRNA) similarly to MWT-treated biofilms of copper (but not PEX) pipes that instead showed higher species diversity (Shannon 4·8, P < 0·05 interaction). Minor chlorine dose addition increased selection pressure and many species were sensitive to chlorination. Pipe material seemed to affect mycobacteria occurrence, and bacterial communities with MWT in copper but not in PEX pipes. This study using rRNA showed that chlorination affects especially active fraction of bacterial communities. Copper and PEX differed by the occurrence of some bacterial members despite similar community profiles. © 2017 The Society for Applied Microbiology.

  12. The Health Effects of Chlorine Dioxide as a Disinfectant in Potable Water: A Literature Survey

    ERIC Educational Resources Information Center

    Calabrese, Edward J.; And Others

    1978-01-01

    The use of chlorine dioxide as a disinfectant in water is being considered by the EPA. This article presents a summary of the known published reports concerning health effects of chlorine dioxide on animal and human populations. (Author/MA)

  13. EVALUATING IN VITRO INFECTIVITY FOR MEASURING UV DISINFECTION OF CRYPTOSPORIDIUM PARVUM OOCYSTS IN FINISHED WATER

    EPA Science Inventory

    UV technology to inactivate Cryptosporidium parvum oocysts has become well established in the US. The challenge now is to effectively demonstrate UV reactor performance and disinfection capacity with various finished water matrices and under different operational conditions. In s...

  14. Reducing the chlorine dioxide demand in final disinfection of drinking water treatment plants using activated carbon.

    PubMed

    Sorlini, Sabrina; Biasibetti, Michela; Collivignarelli, Maria Cristina; Crotti, Barbara Marianna

    2015-01-01

    Chlorine dioxide is one of the most widely employed chemicals in the disinfection process of a drinking water treatment plant (DWTP). The aim of this work was to evaluate the influence of the adsorption process with granular activated carbon (GAC) on the chlorine dioxide consumption in final oxidation/disinfection. A first series of tests was performed at the laboratory scale employing water samples collected at the outlet of the DWTP sand filter of Cremona (Italy). The adsorption process in batch conditions with seven different types of GAC was studied. A second series of tests was performed on water samples collected at the outlet of four GAC columns installed at the outlet of the DWTP sand filter. The results showed that the best chlorine dioxide demand (ClO2-D) reduction yields are equal to 60-80% and are achieved in the first 30 min after ClO2 addition, during the first 16 days of the column operation using a mineral, coal-based, mesoporous GAC. Therefore, this carbon removes organic compounds that are more rapidly reactive with ClO2. Moreover, a good correlation was found between the ClO2-D and UV absorbance at wavelength 254 nm using mineral carbons; therefore, the use of a mineral mesoporous GAC is an effective solution to control the high ClO2-D in the disinfection stage of a DWTP.

  15. Genotoxic and clastogenic effects of monohaloacetic acid drinking water disinfection by-products in primary human lymphocytes.

    PubMed

    Escobar-Hoyos, Luisa F; Hoyos-Giraldo, Luz Stella; Londoño-Velasco, Elizabeth; Reyes-Carvajal, Ingrid; Saavedra-Trujillo, Diana; Carvajal-Varona, Silvio; Sánchez-Gómez, Adalberto; Wagner, Elizabeth D; Plewa, Michael J

    2013-06-15

    The haloacetic acids (HAAs) are the second-most prevalent class of drinking water disinfection by-products formed by chemical disinfectants. Previous studies have determined DNA damage and repair of HAA-induced lesions in mammalian and human cell lines; however, little is known of the genomic DNA and chromosome damage induced by these compounds in primary human cells. The aim of this study was to evaluate the genotoxic and clastogenic effects of the monoHAA disinfection by-products in primary human lymphocytes. All monoHAAs were genotoxic in primary human lymphocytes, the rank order of genotoxicity and cytotoxicity was IAA > BAA > CAA. After 6 h of repair time, only 50% of the DNA damage (maximum decrease in DNA damage) was repaired compared to the control. This demonstrates that primary human lymphocytes are less efficient in repairing the induced damage by monoHAAs than previous studies with mammalian cell lines. In addition, the monoHAAs induced an increase in the chromosome aberration frequency as a measurement of the clastogenic effect of these compounds. These results coupled with genomic technologies in primary human cells and other mammalian non-cancerous cell lines may lead to the identification of biomarkers that may be employed in feedback loops to aid water chemists and engineers in the overall goal of producing safer drinking water. Copyright © 2013 Elsevier Ltd. All rights reserved.

  16. 40 CFR 141.530 - What is a disinfection profile and who must develop one?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Enhanced Filtration and Disinfection-Systems Serving Fewer Than 10,000 People Disinfection Profile § 141.530 What is a disinfection... 40 Protection of Environment 22 2010-07-01 2010-07-01 false What is a disinfection profile and who...

  17. Identification of tobacco-specific nitrosamines as disinfection byproducts in chloraminated water.

    PubMed

    Wu, Minghuo; Qian, Yichao; Boyd, Jessica M; Leavey, Shannon; Hrudey, Steve E; Krasner, Stuart W; Li, Xing-Fang

    2014-01-01

    Tobacco-specific nitrosamines (TSNAs) exist in environmental waters; however, it is unknown whether TSNAs can be produced during water disinfection. Here we report on the investigation and evidence of TSNAs as a new class of disinfection byproducts (DBPs). Using five common TSNAs, including (methylnitrosamino)-1-(3-pyridyl)-1-butanone (NNK) and 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanol (NNAL) as the targets, we first developed a solid phase extraction (SPE) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) method capable of rapidly determining these TSNAs at levels as low as 0.02 ng/L in treated water. Using this highly sensitive method, we investigated the occurrence and formation potential (FP) (precursor test conducted in the presence of chloramines) of TSNAs in treated water from two wastewater treatment plants (WWTPs) and seven drinking water treatment plants (DWTPs). NNAL was detected in the FP samples, but not in the samples before the FP test, confirming NNAL as a DBP. NNK was detected in the treated wastewater before the FP test, but its concentration increased significantly after chloramination in two of three tests. Thus, NNK could be a DBP and/or a contaminant in wastewater. Moreover, these TSNAs were detected in FP tests of wastewater-impacted DWTP plant influents in 9 of 11 samples. However, TSNAs were not detected at full-scale DWTPs, except for at one DWTP with high ammonia where breakpoint chlorination was not achieved. The concentration of the sum of five TSNAs (0.3 ng/L) was 100-fold lower than NDMA, suggesting that TSNAs have a minor contribution to total nitrosamines in water. We examined several factors in the treatment process and found that chlorine or ozone may destroy TSNA precursors and granular activated carbon (GAC) treatment may remove the precursors. Further research is warranted into the efficiency of these processes at different DWTPs using sources of varying water quality.

  18. Inactivation, reactivation and regrowth of indigenous bacteria in reclaimed water after chlorine disinfection of a municipal wastewater treatment plant.

    PubMed

    Li, Dan; Zeng, Siyu; Gu, April Z; He, Miao; Shi, Hanchang

    2013-07-01

    Disinfection of reclaimed water prior to reuse is important to prevent the transmission of pathogens. Chlorine is a widely utilized disinfectant and as such is a leading contender for disinfection of reclaimed water. To understand the risks of chlorination resulting from the potential selection of pathogenic bacteria, the inactivation, reactivation and regrowth rates of indigenous bacteria were investigated in reclaimed water after chlorine disinfection. Inactivation of total coliforms, Enterococcus and Salmonella showed linear correlations, with constants of 0.1384, 0.1624 and 0.057 L/(mg.min) and R2 of 0.7617, 0.8316 and 0.845, respectively. However, inactivation of total viable cells by measurement of metabolic activity typically showed a linear correlation at lower chlorine dose (0-22 (mg-min)/L), and a trailing region with chlorine dose increasing from 22 to 69 (mg.min)/L. Reactivation and regrowth of bacteria were most likely to occur after exposure to lower chlorine doses, and extents of reactivation decreased gradually with increasing chlorine dose. In contrast to total coliforms and Enterococcus, Salmonella had a high level of regrowth and reactivation, and still had 2% regrowth even after chlorination of 69 (mg.min)/L and 24 hr storage. The bacterial compositions were also significantly altered by chlorination and storage of reclaimed water, and the ratio of Salmonella was significantly increased from 0.001% to 0.045% after chlorination of 69 (mg.min)/L and 24 hr storage. These trends indicated that chlorination contributes to the selection of chlorine-resistant pathogenic bacteria, and regrowth of pathogenic bacteria after chlorination in reclaimed water with a long retention time could threaten public health security during wastewater reuse.

  19. DISINFECTION BY-PRODUCTS OF HEALTH CONCERN IN DRINKING WATER: RESULTS OF A NATIONWIDE OCCURRENCE STUDY

    EPA Science Inventory

    Drinking water disinfection by-products (DBPs) are of concern because some epidemiologic studies have shown that some DBPs are associated with cancer or adverse reproductive/developmental effects in human populations, and other studies have shown that certain DBPs cause similar h...

  20. Suitability of electrolyzed oxidizing water for the disinfection of hard surfaces and equipment in radiology.

    PubMed

    Pintaric, Robert; Matela, Joze; Pintaric, Stefan

    2015-01-01

    Hospitals are faced with increasingly resistant strains of micro-organisms. When it comes to disinfection, individual parts of electronic equipment of angiology diagnostics such as patient couches of computer tomography (CT) and magnetic resonance imaging (MRI) scanners prove to be very hard to disinfect. Disinfectants of choice are therefore expected to possess properties such as rapid, residue-free action without any damaging effect on the sensitive electronic equipment. This paper discusses the use of the neutral electrolyzed oxidizing water (EOW) as a biocide for the disinfection of diagnostic rooms and equipment. The CT and MRI rooms were aerosolized with EOW using aerosolization device. The presence of micro-organisms before and after the aerosolization was recorded with the help of sedimentation and cyclone air sampling. Total body count (TBC) was evaluated in absolute and log values. The number of micro-organisms in hospital rooms was low as expected. Nevertheless, a possible TBC reduction between 78.99-92.50% or 50.50-70.60% in log values was recorded. The research has shown that the use of EOW for the air and hard surface disinfection can considerably reduce the presence of micro-organisms and consequently the possibility of hospital infections. It has also demonstrated that the sedimentation procedure is insufficient for the TBC determination. The use of Biocide aerosolization proved to be efficient and safe in all applied ways. Also, no eventual damage to exposed devices or staff was recorded.

  1. Nanodetection of the disinfection by-products on GC-MS techniques

    NASA Astrophysics Data System (ADS)

    Ristoiu, Dumitru; Haydee, Melinda; Ristoiu, Tania

    2009-01-01

    Exposures to disinfection by-products (DBPs) in residential drinking water occur through multiple routes and vary across the population because of differences in the amount and ways people use water. Municipal water in the Romania is disinfected, with chlorine being the most common disinfectant agent. Disinfection of water, in additional to having the benefit of destroying microbes that can transmit diseases, has the drawback of producing a series of compounds known as disinfection by-products (DBPs). Chlorination produces many compounds containing chlorine and/or bromine, some of which have been shown to be carcinogenic, mutagenic, and/or teratogenic in animal studies. The most abundant class of DBPs that result from chlorination of drinking water are trihalomethanes (THMs) - chloroform (CHCl3), dichlorobromomethane (CHCl2Br), dibromochloromethane (CHBr2Cl) and bromoform (CHBr3). The most predominant THM species was CHCl3 and it highest concentration was 85•106 ng/m3. The others THMs compounds concentration were lower, between 65•104 ng/m3 and 12•106 ng/m3. THMs compounds were analyzed on gas chromatography coupled with mass spectrometer detector (GC-MS) and head space technique (HS) was used for all analysis.

  2. Disinfection by-products and microbial contamination in the treatment of pool water with granular activated carbon.

    PubMed

    Uhl, W; Hartmann, C

    2005-01-01

    For swimming pools, it is generally agreed that free chlorine levels have to be maintained to guarantee adequate disinfection. Recommended free chlorine levels can vary between 0.3 and 0.6 mg/L in Germany and up to 3 mg/L in other countries. Bathers introduce considerable amounts of organic matter, mainly in the form of such as urine and sweat, into the pool water. As a consequence, disinfection byproducts (DBPs) are formed. Regulations in Germany recommend levels of combined chlorine of less than 0.2 mg/L and levels of trihalomethanes (THMs) of less than 20 microg/L. Haloacetic acids (HAAs), haloacetonitriles (HANs), chloropicrin and chloral hydrate are also detected in considerable amounts. However, these compounds are not regulated yet. Swimming pool staff and swimmers, especially athletes, are primarily exposed to these byproducts by inhalation and/or dermal uptake. In Germany, new regulations for swimming pool water treatment generally require the use of activated carbon. In this project, three different types of granular activated carbon (GAC) (one standard GAC, two catalytic GACs) are compared for their long time behaviour in pool water treatment. In a pilot plant operated with real swimming pool water, production and removal of disinfection byproducts (THMs, HAAs, AOXs), of biodegradable substances (AOC), of bacteria (Pseudomonas aeruginosa, Legionella, coliforms, HPC) as well as the removal of chlorine and chloramines are monitored as function of GAC bed depth. Combined chlorine penetrates deeper in the filter bed than free chlorine does. However, both, free and combined chlorine removal efficiencies decrease over the time of filter operation. The decreases of removal efficiencies are also observed for parameters such as dissolved organic carbon, spectral absorption coefficient, adsorbable organic carbon and most of the disinfection byproducts. However, THMs, especially chloroform are produced in the filter bed. The GAC beds were contaminated microbially

  3. What's in The Pool? A Comprehensive Identification Of Disinfection By-Products and Assessment of Mutagenicity of Chlorinated and Brominated Swimming Pool Water

    EPA Science Inventory

    Swimming pool disinfectants and disinfection by-products (DBPs) have been linked to human health effects, including asthma and bladder cancer, but no studies have provided a comprehensive identification of DBPs in the water and related that to mutagenicity. We performed a compreh...

  4. Disinfection of bacteriophage MS2 by copper in water.

    PubMed

    Armstrong, Andrew M; Sobsey, Mark D; Casanova, Lisa M

    2017-09-01

    Households that lack piped water supply are often forced to meet water needs by storing in the home, leaving water vulnerable to contamination by viruses. Storage in copper containers can potentially prevent this type of contamination, but the inactivation kinetics of viruses by copper need to be described to make appropriate storage recommendations. This work characterized inactivation kinetics of bacteriophage MS2 as a surrogate for enteric viruses by dissolved ionic copper in water. Reduction of MS2 increased with increasing doses of copper. At 0.3 mg/L, there was a 1.8-log 10 reduction of MS2 within 6 h. At 1 and 3 mg/L, 2-2.5 log 10 inactivation could be achieved between 6 and 24 h. Parameters for the Chick-Watson, Hom, and One Hit-Two Population models of inactivation were calculated and evaluated, all of which demonstrated strong goodness-of-fit and predictability at various contact times. Copper inactivates MS2 under controlled conditions at doses between 0.3 and 3 mg/L. Although requiring longer contact times than conventional disinfectants, it is a candidate for improving the safety of stored drinking water.

  5. Genotoxic properties of haloacetonitriles: drinking water by-products of chlorine disinfection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Daniel, F.B.; Schenck, K.M.; Mattox, J.K.

    Chlorinated and brominated haloacetonitriles (HAN), known drinking water contaminants which form during chlorine disinfection, were investigated for genotoxic activity. The HAN produced DNA strand breaks in cultured human lymphoblastic (CCRF-CEM) cells, bound to the nucleophilic trapping agent 4-(p-nitrobenzyl)pyridine and formed a covalent bond to polyadenylic acid in a cell-free reaction system. Thus, we have demonstrated that these chemicals are genotoxic, which would indicate a potential for carcinogenic activity and for human health hazard.

  6. The present status of research on the disinfection of drinking water in the USSR

    PubMed Central

    Čerkinskij, S. N.; Trahtman, N.

    1972-01-01

    The article reviews recent research in the USSR aimed at evaluating methods of disinfecting drinking water and at elucidating the mechanisms involved. The use of chlorine, ozone, and gamma rays is discussed, as are their advantages and disadvantages and their effects on Enterobacteriaceae and on enteroviruses. PMID:4537489

  7. Facile preparation of silver nanoparticle decorated chitosan cryogels for point-of-use water disinfection.

    PubMed

    Fan, Meikun; Gong, Lin; Huang, Yuting; Wang, Dongmei; Gong, Zhengjun

    2018-02-01

    In this study, silver nanoparticle decorated chitosan (CS/Ag NP) cryogels were fabricated through a simple freeze-drying process for point-of-use (POU) water disinfection. The CS/Ag NP cryogels showed high porosity, good mechanical properties, an excellent water absorption capability, and most importantly, an efficient bactericidal feature. The absorption capacity for water was found to be 47g/g, approximately 90% of which was recovered by simple squeezing. Three different sizes of Ag NPs were compared regarding their bactericidal capability against both Escherichia coli (E. coli) and Bacillus subtilis (B. subtilis). Under optimum conditions, a 3 log reduction of bacteria was observed by holding the bacteria suspension (10 8 colony forming units (cfu)/mL) in the cryogels for 5min. Reduction was further increased to a 4 log when the contact time was doubled. The silver content in the cryogels was found to only be 7.5mg/g. Furthermore, the total Ag in processed water was found to only be 22μg/L, half of the safety limit set by China (<50μg/L). The bactericidal effectiveness of the material for real surface water samples was also demonstrated by treating water samples with different water quality matrices, including lake water and sewage water samples. In all three treated lake water samples, both the total bacteria and E. coli met the regulations for drinking water in China (<100cfu/mL for total bacteria and negative for E. coli). CS/Ag NP cryogels can be used for drinking water disinfection during disaster relief and in contingency water supply applications. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Assessing point-of-use ultraviolet disinfection for safe water in urban developing communities.

    PubMed

    Barstow, Christina K; Dotson, Aaron D; Linden, Karl G

    2014-12-01

    Residents of urban developing communities often have a tap in their home providing treated and sometimes filtered water but its microbial quality cannot be guaranteed. Point-of-use (POU) disinfection systems can provide safe drinking water to the millions who lack access to clean water in urban communities. While many POU systems exist, there are several concerns that can lead to low user acceptability, including low flow rate, taste and odor issues, high cost, recontamination, and ineffectiveness at treating common pathogens. An ultraviolet (UV) POU system was constructed utilizing developing community-appropriate materials and simple construction techniques based around an inexpensive low-wattage, low pressure UV bulb. The system was tested at the bench scale to characterize its hydrodynamic properties and microbial disinfection efficacy. Hydraulically the system most closely resembled a plug flow reactor with minor short-circuiting. The system was challenge tested and validated for a UV fluence of 50 mJ/cm(2) and greater, over varying flow rates and UV transmittances, corresponding to a greater than 4 log reduction of most pathogenic bacteria, viruses, and protozoa of public health concern. This study presents the designed system and testing results to demonstrate the potential architecture of a low-cost, open-source UV system for further prototyping and field-testing.

  9. Relationship between antibiotic- and disinfectant-resistance profiles in bacteria harvested from tap water.

    PubMed

    Khan, Sadia; Beattie, Tara K; Knapp, Charles W

    2016-06-01

    Chlorination is commonly used to control levels of bacteria in drinking water; however, viable bacteria may remain due to chlorine resistance. What is concerning is that surviving bacteria, due to co-selection factors, may also have increased resistance to common antibiotics. This would pose a public health risk as it could link resistant bacteria in the natural environment to human population. Here, we investigated the relationship between chlorine- and antibiotic-resistances by harvesting 148 surviving bacteria from chlorinated drinking-water systems and compared their susceptibilities against chlorine disinfectants and antibiotics. Twenty-two genera were isolated, including members of Paenibacillus, Burkholderia, Escherichia, Sphingomonas and Dermacoccus species. Weak (but significant) correlations were found between chlorine-tolerance and minimum inhibitory concentrations against the antibiotics tetracycline, sulfamethoxazole and amoxicillin, but not against ciprofloxacin; this suggest that chlorine-tolerant bacteria are more likely to also be antibiotic resistant. Further, antibiotic-resistant bacteria survived longer than antibiotic-sensitive organisms when exposed to free chlorine in a contact-time assay; however, there were little differences in susceptibility when exposed to monochloramine. Irrespective of antibiotic-resistance, spore-forming bacteria had higher tolerance against disinfection compounds. The presence of chlorine-resistant bacteria surviving in drinking-water systems may carry additional risk of antibiotic resistance. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. 76 FR 39092 - Agency Information Collection Activities; Proposed Collection; Comment Request; Disinfectants...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-05

    ...; Disinfectants/Disinfection Byproducts, Chemical and Radionuclides; Microbial; and Public Water System...://www.epa.gov/epahome/dockets.htm . FOR FURTHER INFORMATION CONTACT: Matthew Reed, Drinking Water Protection Division, Office of Ground Water and Drinking Water, (4606M), Environmental Protection Agency...

  11. Visible-light-driven, water-surface-floating antimicrobials developed from graphitic carbon nitride and expanded perlite for water disinfection.

    PubMed

    Zhang, Chi; Li, Yi; Shuai, Danmeng; Zhang, Wenlong; Niu, Lihua; Wang, Longfei; Zhang, Huanjun

    2018-05-28

    Waterborne pathogens, especially bacteria and viruses, pose significant health risks to the public, calling for the development of a sustainable, efficient, and robust disinfection strategy with reduced energy footprint and minimized byproduct formation. Here, we developed a sustainable photocatalytic composite for antimicrobial applications by integrating visible-light-responsive graphitic carbon nitride (g-C 3 N 4 ) with low-density porous expanded perlite (EP) mineral, and g-C 3 N 4 /EP-520 showed a high specific surface area of 45.3 m 2 /g and optimum performance for disinfection. g-C 3 N 4 /EP-520 achieved 8-log inactivation of E. coli and MS2 under 180 and 240 min visible-light irradiation without stirring, respectively. Water quality parameters were found to influence the disinfection performance of g-C 3 N 4 /EP-520: MS2 inactivation was promoted with the increase of dissolved oxygen (DO), proton concentration, salinity (NaCl), and hardness (Ca 2+ ). Importantly, g-C 3 N 4 /EP-520 could fully inactivate MS2 in a real source water sample with prolonged light irradiation, and negligible activity loss was observed in recycle use, demonstrating its viability and robustness for waterborne pathogen removal. Antimicrobial mechanisms of g-C 3 N 4 /EP-520 were systemically evaluated by radical scavenger addition, and revealed that the inactivation behavior was dependent on the type of microorganisms. Microscopic analyses confirmed that the destruction of bacterial cells and viral particles, leading to the inactivation of microorganisms. Copyright © 2018 Elsevier Ltd. All rights reserved.

  12. MULTISPECTRAL IDENTIFICATION OF CHLORINE DIOXIDE DISINFECTION BYPRODUCTS IN DRINKING WATER

    EPA Science Inventory

    This paper discusses the identification of organic disinfection byproducts (DBPs) at a pilot plant in Evansville, IN, which uses chlorine dioxide as a primary disinfectant. Unconventional multispectral identification techniques (gas chromatography combined with high- and low reso...

  13. Microbial contamination and disinfection methods of pacifiers

    PubMed Central

    NELSON, Paulo; LOUVAIN, Márcia Costa; MACARI, Soraia; LUCISANO, Marília Pacífico; da SILVA, Raquel Assed Bezerra; de QUEIROZ, Alexandra Mussolino; GATON-HERNÁNDEZ, Patrícia; da SILVA, Léa Assed Bezerra

    2015-01-01

    Objectives To evaluate the microbial contamination of pacifiers by Mutans Streptococci (MS) and the efficacy of different methods for their disinfection. Methods Twenty-eight children were assigned to a 4-stage changeover system with a 1-week interval. In each stage, children received a new pacifier and the parents were instructed to maintain their normal habits for 1 week. After this time, the pacifiers were subjected to the following 4 disinfection methods: spraying with 0.12% chlorhexidine solution, Brushtox® or sterile tap water, and immersion in boiling tap water for 15 minutes. Microbiological culture for MS and Scanning Electron Microscopy (SEM) were performed. The results were analyzed statistically by Friedman’s non-parametric test (a=0.05). Results The 0.12% chlorhexidine spray was statistically similar to the boiling water (p>0.05) and more effective than the Brushtox® spray and control (p<0.05). The analysis of SEM showed the formation of a cariogenic biofilm in all groups with positive culture. Conclusions Pacifiers become contaminated by MS after their use by children and should be disinfected routinely. Spraying with a 0.12% chlorhexidine solution and immersion in boiling water promoted better disinfection of the pacifiers compared with a commercial antiseptic toothbrush cleanser (Brushtox®). PMID:26537723

  14. [Decontamination of dental unit waterlines using disinfectants and filters].

    PubMed

    Monarca, S; Garusi, G; Gigola, P; Spampinato, L; Zani, C; Sapelli, P L

    2002-10-01

    Bacterial contamination of the dental unit water system can become a health problem for patients, particularly if they are immunodepressed. The present study has had the purpose of evaluating the effectiveness of methods of chemical decontamination using different disinfectants (peracetic acid, hydrogen peroxide, silver salts, chloramine T, glutaraldehyde T4) and methods of physical decontamination using synthetic membranes for the filtration of water. A preliminary removal procedure of the biofilm present in the waterline has been followed in a dental unit prepared on purpose for the research; subsequently different 2-week long maintenance procedures were applied using disinfectants injected by a pump and finally the bacterial contamination of the water flowing from the waterline was evaluated. The physical decontamination was performed using 0.22 mm membrane filters, which have been installed also in another dental unit, and the filtered water was analyzed to detect bacterial contamination. The preliminary procedure of biofilm removal succeeded obtaining germ-free water. Among the disinfectants used for the maintenance of the water quality only glutaraldehyde T4 was able to reduce the bacterial contamination under the limit suggested by the ADA. The membrane filter system was not able to purify the water, but when a disinfectant (peracetic acid) was used in the last part of the waterline good results were obtained. At present no decontamination system of dental waterline is available, and glutaraldehyde T4 seems to be the best disinfectant only if integrated with periodic biofilm removal for the maintenance of the water quality.

  15. Reproductive and developmental effects of disinfection by-products in drinking water.

    PubMed Central

    Reif, J S; Hatch, M C; Bracken, M; Holmes, L B; Schwetz, B A; Singer, P C

    1996-01-01

    Recent epidemiologic studies have reported associations between the consumption of chlorinated drinking water and reproductive and developmental effects. Here we review the available epidemiologic data, assess the hazard potential posed by exposure to disinfection by-products, identify critical data gaps, and offer recommendations for further research. The epidemiologic evidence supporting associations between exposure to water disinfection by-products (DBPs) and adverse pregnancy outcomes is sparse, and positive findings should be interpreted cautiously. The methods used during the early stages of research in this area have been diverse. Variability in exposure assessment and endpoints makes it difficult to synthesize or combine the available data. Exposure misclassification and unmeasured confounding may have lead to bias in risk estimation. Future studies of reproductive outcome and exposure to chlorinated water should use improved methods for exposure assessment to 1) assure selection of appropriate exposure markers, 2) assess seasonal and annual fluctuations in DBPs, 3) assess variability within the distribution system, and 4) assess exposure through multiple routes such as bathing and showering, as well as consumption. Population-based studies should be conducted to evaluate male and female fertility, conception delay, growth retardation, and specific birth defects. The reproductive and developmental effects of exposure to DBPs could be efficiently explored in ongoing investigations by incorporating valid exposure markers and relevant questionnaire information. Future studies should make use of naturally occurring variability in the concentrations of DBPs and may incorporate biomarkers of exposure and effect in their design. Epidemiologic investigations should be conducted in parallel with laboratory-based and animal studies in a coordinated, multidisciplinary approach. PMID:8930546

  16. Process Requirements for Achieving Full-Flow Disinfection of Recirculating Water Using Ozonation and UV Irradiation

    USDA-ARS?s Scientific Manuscript database

    A continuous water disinfection process can be used to prevent the introduction and accumulation of obligate and opportunistic fish pathogens in recirculating aquaculture systems (RAS), especially during a disease outbreak when the causative agent would otherwise proliferate within the system. To p...

  17. Virus Disinfection in Water by Biogenic Silver Immobilized in Polyvinylidene Fluoride Membranes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    B De Gusseme; T Hennebel; E Christiaens

    The development of innovative water disinfection strategies is of utmost importance to prevent outbreaks of waterborne diseases related to poor treatment of (drinking) water. Recently, the association of silver nanoparticles with the bacterial cell surface of Lactobacillus fermentum (referred to as biogenic silver or bio-Ag{sup 0}) has been reported to exhibit antiviral properties. The microscale bacterial carrier matrix serves as a scaffold for Ag{sup 0} particles, preventing aggregation during encapsulation. In this study, bio-Ag{sup 0} was immobilized in different microporous PVDF membranes using two different pre-treatments of bio-Ag{sup 0} and the immersion-precipitation method. Inactivation of UZ1 bacteriophages using these membranesmore » was successfully demonstrated and was most probably related to the slow release of Ag{sup +} from the membranes. At least a 3.4 log decrease of viruses was achieved by application of a membrane containing 2500 mg bio-Ag{sup 0}{sub powder} m{sup -2} in a submerged plate membrane reactor operated at a flux of 3.1 L m{sup -2} h{sup -1}. Upon startup, the silver concentration in the effluent initially increased to 271 {mu}g L{sub -1} but after filtration of 31 L m{sup -2}, the concentration approached the drinking water limit (= 100 {mu}g L{sup -1}). A virus decline of more than 3 log was achieved at a membrane flux of 75 L m{sup -2} h{sup -1}, showing the potential of this membrane technology for water disinfection on small scale.« less

  18. 40 CFR 141.533 - What data must my system collect to calculate a disinfection profile?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... at each residual disinfectant concentration sampling point during peak hourly flow; (b) If your system uses chlorine, the pH of the disinfected water at each residual disinfectant concentration...; and (d) The residual disinfectant concentration(s) (“C”) of the water before or at the first customer...

  19. 40 CFR 141.533 - What data must my system collect to calculate a disinfection profile?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... at each residual disinfectant concentration sampling point during peak hourly flow; (b) If your system uses chlorine, the pH of the disinfected water at each residual disinfectant concentration...; and (d) The residual disinfectant concentration(s) (“C”) of the water before or at the first customer...

  20. 40 CFR 141.533 - What data must my system collect to calculate a disinfection profile?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... at each residual disinfectant concentration sampling point during peak hourly flow; (b) If your system uses chlorine, the pH of the disinfected water at each residual disinfectant concentration...; and (d) The residual disinfectant concentration(s) (“C”) of the water before or at the first customer...

  1. 40 CFR 141.533 - What data must my system collect to calculate a disinfection profile?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... at each residual disinfectant concentration sampling point during peak hourly flow; (b) If your system uses chlorine, the pH of the disinfected water at each residual disinfectant concentration...; and (d) The residual disinfectant concentration(s) (“C”) of the water before or at the first customer...

  2. CHRONIC EXPOSURE TO DIBROMOACETIC ACID, A WATER DISINFECTION BY-PRODUCT, DIMINISHES PRIMORDIAL FOLLICLES IN THE RABBIT

    EPA Science Inventory

    Exposure to dibromoacetic acid (DBA), a commonly occurring water disinfection by-product, has detrimental effects on spermatogenesis and fertility in rats and rabbits. Despite indications of important reproductive consequences of DBA exposure in males, reproductive sequelae follo...

  3. 40 CFR 141.540 - Who has to develop a disinfection benchmark?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Enhanced Filtration and... significant change to your disinfection practice. Your system must consult with the State for approval before you can implement a significant disinfection practice change. ...

  4. RECOVERY OF MUTAGENICITY FROM DISINFECTED WATER SAMPLES BY XAD RESIN ADSORPTION COMPARED TO REVERSE OSMOSIS

    EPA Science Inventory

    the presence of a complex misture of disinfection byproducts in drinking waters continues to cause concern over the potential long-term health effects of exposure to these compounds. Most of these compounds are present at ug/L levels or less. Consequently, some method of concentr...

  5. Comparison of permanganate preoxidation and preozonation on algae containing water: cell integrity, characteristics, and chlorinated disinfection byproduct formation.

    PubMed

    Xie, Pengchao; Ma, Jun; Fang, Jingyun; Guan, Yinghong; Yue, Siyang; Li, Xuchun; Chen, Liwei

    2013-12-17

    Aqueous suspensions of Microcystis aeruginosa were preoxidized with either ozone or permanganate and then subjected to chlorination under conditions simulating drinking water purification. The impacts of the two oxidants on the algal cells and on the subsequent production of dissolved organic matter and disinfection byproducts were investigated. Preozonation dramatically increased disinfection byproduct formation during chlorination, especially the formation of haloaldehydes, haloacetonitriles, and halonitromethanes. Preoxidation with permanganate had much less effect on disinfection byproduct formation. Preozonation destroyed algal cell walls and cell membranes to release intracellular organic matter (IOM), and less than 2.0% integrated cells were left after preozonation with the dosage as low as 0.4 mg/L. Preoxidation with permanganate mainly released organic matter adsorbed on the cells' surface without causing any damage to the cells' integrity, so the increase in byproduct formation was much less. More organic nitrogen and lower molecular weight precursors were produced in a dissolved phase after preozonation than permanganate preoxidation, which contributes to the significant increase of disinfection byproducts after preozonation. The results suggest that permanganate is a better choice than ozone for controlling algae derived pollutants and disinfection byproducts.

  6. Evaluation of Disinfection Byproducts Formed from the Chlorination of Lyophilized and Reconstituted NOM Concentrate from a Drinking Water Source - Poster

    EPA Science Inventory

    Drinking water treatment and disinfection byproduct (DBP) research can be complicated by difficulties in shipping large water quantities and NOM geographical and temporal variability. Access to a drinking water representative, shelf-stable, concentrated NOM source would solve th...

  7. Innovative Plasma Disinfection Technique with the Reduced-pH Method and the Plasma-Treated Water (PTW) -Safety and Powerful Disinfection with Cryopreserved PTW-

    NASA Astrophysics Data System (ADS)

    Kitano, Katsuhisa; Ikawa, Satoshi; Nakashima, Yoichi; Tani, Atsushi; Yokoyama, Takashi; Ohshima, Tomoko

    2015-09-01

    Among the applications of the plasma disinfection to human body, plasma sterilization in liquid is crucial. We found that the plasma-treated water (PTW) has strong bactericidal activity under low pH condition and the half-lives of its activity depend on temperature. Lower temperature brings longer half-life and the bactericidal activity of PTW can be kept by cryopreservation. These physicochemical properties were in accordance with Arrhenius equation both in liquid and solid states. From the experimental results of ESR (Electron Spin Resonance) measurement of O2-in liquid against PTW with spin trapping method, half-lives of PTW were also in accordance with Arrhenius equation. It suggests that high concentration PTW as integrated value can be achieved by cooling of plasma apparatus. Pure PTW has disinfection power of 22 log reduction (B. subtilis). This corresponds to 65% H2O2, 14% hypochlorous acid and 0.33% peracetic acid, which are deadly poison for human. On the other hand, PTW is deactivated soon at body temperature. This indicates that toxicity to human body seems to be low. PTW, which is a sort of indirect plasma exposure, with pH and temperature controls could be applied for safety and powerful disinfection. MEXT (15H03583, 23340176, 25108505). NCCE (23-A-15).

  8. Simultaneous control of microorganisms and disinfection by-products by sequential chlorination.

    PubMed

    Chen, Chao; Zhang, Xiao-Jian; He, Wen-Jie; Han, Hong-Da

    2007-04-01

    To introduce a new sequential chlorination disinfection process in which short-term free chlorine and chloramine are sequentially added. Pilot tests of this sequential chlorination were carried out in a drinking water plant. The sequential chlorination disinfection process had the same or better efficiency on microbe (including virus) inactivation compared with the free chlorine disinfection process. There seemed to be some synergetic disinfection effect between free chlorine and monochloramine because they attacked different targets. The sequential chlorination disinfection process resulted in 35.7%-77.0% TTHM formation and 36.6%-54.8% THAA5 formation less than the free chlorination process. The poorer the water quality was, the more advantage the sequential chlorination disinfection had over the free chlorination. This process takes advantages of free chlorine's quick inactivation of microorganisms and chloramine's low disinfection by-product (DBP) yield and long-term residual effect, allowing simultaneous control of microbes and DBPs in an effective and economic way.

  9. What’s in the Pool? A Comprehensive Identification of Disinfection By-Products and Assessment of Mutagenicity of Chlorinated and Brominated Swimming Pool Water

    EPA Science Inventory

    Swimming pool disinfectants and disinfection by-products (DBPs) have been linked to human health effects, including asthma and bladder cancer, but no studies have provided a comprehensive identification of DBPs in pool water and related those DBPs to the mutagenicity of pool wate...

  10. Drinking water disinfection by-products and time to pregnancy.

    PubMed

    MacLehose, Richard F; Savitz, David A; Herring, Amy H; Hartmann, Katherine E; Singer, Philip C; Weinberg, Howard S

    2008-05-01

    Laboratory evidence suggests tap water disinfection by-products (DBPs) could have an effect very early in pregnancy, typically before clinical detectability. Undetected early losses would be expected to increase the reported number of cycles to clinical pregnancy. We investigated the association between specific DBPs (trihalomethanes, haloacetic acids, brominated-trihalomethanes, brominated-haloacetic acids, total organic halides, and bromodichloromethane) and time to pregnancy among women who enrolled in a study of drinking water and reproductive outcomes. We quantified exposure to DBPs through concentrations in tap water, quantity ingested through drinking, quantity inhaled or absorbed while showering or bathing, and total integrated exposure. The effect of DBPs on time to pregnancy was estimated using a discrete time hazard model. Overall, we found no evidence of an increased time to pregnancy among women who were exposed to higher levels of DBPs. A modestly decreased time to pregnancy (ie, increased fecundability) was seen among those exposed to the highest level of ingested DBPs, but not for tap water concentration, the amount absorbed while showering or bathing, or the integrated exposure. Our findings extend those of a recently published study suggesting a lack of association between DBPs and pregnancy loss.

  11. Analysis, Occurrence and Toxicity of Haloacetaldehydes in Drinking Waters: Iodacetaldehyde as an Emerging Disinfection ByProduct.

    EPA Science Inventory

    Chlorinated and brominated haloacetaldehydes (HALs) are consideredthe 3rd largest class of disinfection by-products (DBPs) by weight. The iodinatedHAL, iodoacetaldehyde, has been recently reported as an emerging DBP infinished drinking waters. Overall, iodinated DBPs, e.g., iodoa...

  12. Disinfectant and antimicrobial susceptibility profiles of Salmonella strains from feedlot water-sprinkled cattle: hides and feces

    USDA-ARS?s Scientific Manuscript database

    The disinfectant and antimicrobial susceptibility profiles of 145 Salmonella strains obtained from feedlot water sprinkled cattle were determined. A low prevalence of antimicrobial resistance (AMR) was observed; resistance was primarily observed to streptomycin (29.7%) and sulfamethoxazole (8.3%). ...

  13. IDENTIFICATION OF PROTEINS INVOLVED IN TESTICULAR TOXICITY INDUCED BY HALOACID BY-PRODUCTS OF DRINKING WATER DISINFECTION

    EPA Science Inventory

    Dibromoacetic acid (DBA), a prevalent disinfection by-product in drinking water, perturbs spermiogenesis in adult rats suggesting that Sertoli-germ cell communication is compromised. When isolated seminiferous tubules from rats exposed to DBA in vivo were cultured, quantitative a...

  14. Assessment of reproductive effects on complex mixtures of disinfection by-products in a multigenerational rat bioassay of drinking water concentrates

    EPA Science Inventory

    To address concerns raised by epidemiology studies, we conducted a multigenerational reproductive toxicity study in rats using a “whole” mixture of drinking water disinfection by-products (DBPs). Raw water was concentrated ~130 fold, chlorinated, and provided as drinking water to...

  15. Disinfection of human enteric viruses in water by copper and silver in combination with low levels of chlorine.

    PubMed Central

    Abad, F X; Pintó, R M; Diez, J M; Bosch, A

    1994-01-01

    The efficacy of copper and silver ions, in combination with low levels of free chlorine (FC), was evaluated for the disinfection of hepatitis A virus (HAV), human rotavirus (HRV), human adenovirus, and poliovirus (PV) in water. HAV and HRV showed little inactivation in all conditions. PV showed more than a 4 log10 titer reduction in the presence of copper and silver combined with 0.5 mg of FC per liter or in the presence of 1 mg of FC per liter alone. Human adenovirus persisted longer than PV with the same treatments, although it persisted significantly less than HRV or HAV. The addition of 700 micrograms of copper and 70 micrograms of silver per liter did not enhance the inactivation rates after the exposure to 0.5 or 0.2 mg of FC per liter, although on some occasions it produced a level of inactivation similar to that induced by a higher dose of FC alone. Virus aggregates were observed in the presence of copper and silver ions, although not in the presence of FC alone. Our data indicate that the use of copper and silver ions in water systems may not provide a reliable alternative to high levels of FC for the disinfection of viral pathogens. Gene probe-based procedures were not adequate to monitor the presence of infectious HAV after disinfection. PV does not appear to be an adequate model viral strain to be used in disinfection studies. Bacteroides fragilis bacteriophages were consistently more resistant to disinfection than PV, suggesting that they would be more suitable indicators, although they survived significantly less than HAV or HRV. Images PMID:8074518

  16. Efficacy of uv irradiation in the microbial disinfection of marine mammal water

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Spotte, S.; Buck, J.D.

    A study was made on the efficacy of a commercial ultraviolet (UV) sterilizer in reducing the number of bacteria and yeasts in a saline, closed-system marine mammal complex. UV irradiation was effective in lowering bacterial counts in the effluent of the unit (greater than 75% reduction), but bacteria in more remote parts of the water system reached levels equal to or greater than pre-UV counts. Yeast reduction was considerably less, and a trend similar to that of the bacteria was observed in remote sections of the water system. It is concluded that UV irradiation is of limited value in themore » disinfection of marine mammal water. Factors contributing to the poor performance of the sterilizer were the long recycle time of the water and lack of a residual effect.« less

  17. Comparison of cleaning efficacy between in-use disinfectant and electrolysed water in an English residential care home.

    PubMed

    Meakin, N S; Bowman, C; Lewis, M R; Dancer, S J

    2012-02-01

    Infection control in hospitals and care homes remains a key issue. They are regularly inspected regarding standards of hygiene, but visual assessment does not necessarily correlate with microbial cleanliness. Pathogens can persist in the inanimate environment for extended periods of time. This prospective study compared the effectiveness of a novel sanitizer containing electrolysed water, in which the active ingredient is stabilized hypochlorous acid (Aqualution™), with the effectiveness of the quaternary ammonium disinfectant in current use for microbial removal from hand-touch surfaces in a care home. The study had a two-period crossover design. Five surfaces were cleaned daily over a four-week period, with screening swabs taken before and after cleaning. Swabs were cultured in order to compare levels of surface microbial contamination [colony-forming units (cfu)/cm(2)] before and after cleaning with each product. Cleaning with electrolysed water reduced the mean surface bacterial load from 2.6 [interquartile range (IQR) 0.30-30.40] cfu/cm(2) to 0.10 (IQR 0.10-1.40) cfu/cm(2) [mean log(10) reduction factor 1.042, 95% confidence interval (CI) 0.79-1.30]. Cleaning with the in-use quaternary ammonium disinfectant increased the bacterial load from 0.90 (IQR 0.10-8.50) cfu/cm(2) to 93.30 (IQR 9.85-363.65) cfu/cm(2) (mean log(10) reduction -1.499, 95% CI -1.87 to -1.12) (P < 0.0001). Using two proposed benchmark standards for surface microbial levels in hospitals, electrolysed water resulted in a higher 'pass rate' than the in-use quaternary ammonium disinfectant (80-86% vs 15-21%, P < 0.0001). Electrolysed water exerts a more effective bacterial kill than the in-use quaternary ammonium disinfectant, which suggests that it may be useful as a surface sanitizer in environments such as care homes. Copyright © 2011 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  18. OXIDATIVE DNA DAMAGE FROM POTASSIUM BROMATE EXPOSURE IN LONG-EVANS RATS IS NOT ENHANCED BY A MIXTURE OF DRINKING WATER DISINFECTION BY-PRODUCTS

    EPA Science Inventory

    Public drinking water treated with chemical disinfectants contains a complex mixture of disinfection by-products (DBPs) for which the relative toxicity of the mixtures needs to be characterized to accurately assess risk. Potassium bromate (KBrO3) is a by-product from ozonation of...

  19. Drugs, diagnostic agents and disinfectants in wastewater and water--a review.

    PubMed

    Kümmerer, K

    2000-01-01

    After administration pharmaceuticals are excreted by the patients into the aquatic environment via wastewater. Unused medications are sometimes disposed of in drains. The drugs may enter the aquatic environment and eventually reach drinking water, if they are not biodegraded or eliminated during sewage treatment. Additionally, antibiotics and disinfectants are assumed to disturb the wastewater treatment process and the microbial ecology in surface waters. Furthermore, resistant bacteria may be selected in the aeration tanks of sewage treatment plants by the antibiotic substances present. Since the 1980s, data on the occurrence of pharmaceuticals in natural surface waters and the effluents of sewage treatment plants have been reported. More recently, pharmaceuticals have been detected in ground and drinking water. However, only little is known about the risk imposed on humans by pharmaceuticals and their metabolites in surface and drinking water. An overview of input, occurrence, elimination (e.g. biodegradability) and possible effects of different pharmaceutical groups such as anti-tumour drugs, antibiotics and contrast media as well as AOX resulting from hospitals effluent input into sewage water and surface water is presented.

  20. CONDUCTING A RISK ASSESSMENT OF MIXTURES OF DISINFECTION BY-PRODUCTS (DBPS) FOR DRINKING WATER TREATMENT SYSTEMS

    EPA Science Inventory

    The risk assessment of disinfection by-product (DBP) mixtures in drinking water is an important issue in environmental health. To generate improved assessments of DBP mixture health risk, EPA scientists have explored a number of novel approaches to generating realistic, central ...

  1. Nanosilver as a disinfectant in dental unit waterlines ...

    EPA Pesticide Factsheets

    Dental unit water lines (DUWL) are susceptible to biofilm development and bacterial growth leading to water contamination, causing health and ecological effects. This study monitors the interactions between a commonly used nanosilver disinfectant (ASAP-AGX-32, an antimicrobial cleaner for dental units, 0.0032% Ag) and biofilm development in DUWL. To simulate the disinfection scenario, an in-house DUWL model was assembled and biofilm accumulation was allowed. Subsequent to biofilm development, the disinfection process was performed according to the manufacturer's instructions. The pristine nanosilver particles in the cleaner measured between 3 and 5 nm in diameter and were surrounded by a stabilizing polymer. However, the polymeric stabilizing agent diminished over the disinfection process, initiating partial AgNPs aggregation. Furthermore, surface speciation of the pristine AgNPs were identified as primarily AgO, and after the disinfection process, transformations to AgCl were observed. The physicochemical characteristics of AgNPs are known to govern their fate, and transport and environmental implications. Hence, knowledge of the AgNPs characteristics after the disinfection process (usage scenario) is of significance. This study demonstrates the adsorption of AgNPs onto biofilm surfaces and, therefore, will assist in illustration of the toxicity mechanisms of AgNPs to bacteria and biofilms. This work can be an initial step in better understanding how

  2. On the factors influencing the performance of solar reactors for water disinfection with photosensitized singlet oxygen.

    PubMed

    Manjón, Francisco; Villén, Laura; García-Fresnadillo, David; Orellana, Guillermo

    2008-01-01

    Two solar reactors based on compound parabolic collectors (CPCs) were optimized for water disinfection by photosensitized singlet oxygen (1O2) production in the heterogeneous phase. Sensitizing materials containing Ru(II) complexes immobilized on porous silicone were produced, photochemically characterized, and successfully tested for the inactivation of up to 10(4) CFU mL(-1) of waterborne Escherichia coli (gram-negative) or Enterococcus faecalis (gram-positive) bacteria. The main factors determining the performance of the solar reactors are the type of photosensitizing material, the sensitizer loading, the CPC collector geometry (fin- vs coaxial-type), the fluid rheology, and the balance between concurrent photothermal--photolytic and 1O2 effects on the microorganisms' inactivation. In this way, at the 40 degrees N latitude of Spain, water can be disinfected on a sunny day (0.6-0.8 MJ m(-2) L(-1) accumulated solar radiation dose in the 360-700 nm range, typically 5-6 h of sunlight) with a fin-type reactor containing 0.6 m2 of photosensitizing material saturated with tris(4,7-diphenyl-1,10-phenanthroline)ruthenium(II) (ca. 2.0 g m(-2)). The optimum rheological conditions require laminar-to-transitional water flow in both prototypes. The fin-type system showed better inactivation efficiency than the coaxial reactor due to a more important photolytic contribution. The durability of the sensitizing materials was tested and the operational lifetime of the photocatalyst is at least three months without any reduction in the bacteria inactivation efficiency. Solar water disinfection with 1O2-generating films is demonstrated to be an effective technique for use in isolated regions of developing countries with high yearly average sunshine.

  3. Quality of tomato slices disinfected with ozonated water.

    PubMed

    Aguayo, Encarna; Escalona, Víctor; Silveira, Ana Cecilia; Artés, Francisco

    2014-04-01

    Fresh-cut industry needs novel disinfectant to replace the use of chlorine. Ozone is one of the most powerful oxidizing agents and is applied in gaseous or aqueous form for sanitation purposes. However, the strong oxidative effect could affect the nutritional and sensorial quality, in particular, when time of washing is extended. For that reason, the overall impact of ozonated water (0.4 mg/L) dipping applied during 1, 3 and 5 min compared to control washed in water during 5 min was studied in tomato slices stored during 14 days at 5 . According to the results, ozonated water treatment of 3 min achieved the best firmness retention, microbial quality (mesophilic, psychrotrophic and yeas load) and reduced the consumption of fructose and glucose. The use of ozonated water did not affect the total acidity, pH, total solid soluble, organic acid as ascorbic, fumaric or succinic acid and the sensorial parameters, which were only affected by storage time. However, the poor appearance, aroma and overall quality obtained in all treatments prevented shelf life of 14 days and the quality at acceptable levels was established in 10 days at 5 . It is recommended to wash tomato slices with 0.4 mg/L ozonated water for 3 min only. Extending treatment duration did not improve the microbiological quality, possibly due to the extra time permitting the ozone to react with other components of the fruit tissue, undermining the antimicrobial benefits.

  4. Frequency of use controls chemical leaching from drinking-water containers subject to disinfection.

    PubMed

    Andra, Syam S; Makris, Konstantinos C; Shine, James P

    2011-12-15

    Microbial-, and chemical-based burden of disease associated with lack of access to safe water continues to primarily impact developing countries. Cost-effective health risk-mitigating measures, such as of solar disinfection applied to microbial-contaminated water stored in plastic bottles have been increasingly tested in developing countries adversely impacted by epidemic water-borne diseases. Public health concerns associated with chemical leaching from water packaging materials led us to investigate the magnitude and variability of antimony (Sb) and bromine (Br) leaching from reused plastic containers (polyethylene terephthalate, PET; and polycarbonate, PC) subject to UV and/or temperature-driven disinfection. The overall objective of this study was to determine the main and interactive effects of temperature, UV exposure duration, and frequency of bottle reuse on the extent of leaching of Sb and Br from plastic bottles into water. Regardless of UV exposure duration, frequency of reuse (up to 27 times) was the major factor that linearly increased Sb leaching from PET bottles at all temperatures tested (13-47 °C). Leached Sb concentrations (∼360 ng L(-1)) from the highly reused (27 times) PET bottles (minimal Sb leaching from PC bottles, <15 ng L(-1)) did not pose a serious risk to human health according to current daily Sb acceptable intake estimates. Leached Br concentrations from both PET and PC containers (up to ∼15 μg L(-1)) did not pose a consumer health risk either, however, no acceptable daily dose estimates exist for oral ingestion of organo-brominated, or other plasticizers/additives compounds if they were to be found in bottled water at much lower concentrations. Additional research on potential leaching of organic chemicals from water packaging materials is deemed necessary under relevant environmental conditions. Copyright © 2011 Elsevier Ltd. All rights reserved.

  5. Toxicity of drinking water disinfection byproducts: cell cycle alterations induced by the monohaloacetonitriles.

    PubMed

    Komaki, Yukako; Mariñas, Benito J; Plewa, Michael J

    2014-10-07

    Haloacetonitriles (HANs) are a chemical class of drinking water disinfection byproducts (DBPs) that form from reactions between disinfectants and nitrogen-containing precursors, the latter more prevalent in water sources impacted by algae bloom and municipal wastewater effluent discharge. HANs, previously demonstrated to be genotoxic, were investigated for their effects on the mammalian cell cycle. Treating Chinese hamster ovary (CHO) cells with monoHANs followed by the release from the chemical treatment resulted in the accumulation of abnormally high DNA content in cells over time (hyperploid). The potency for the cell cycle alteration followed the order: iodoacetonitrile (IAN) > bromoacetonitrile (BAN) ≫ chloroacetonitrile (CAN). Exposure to 6 μM IAN, 12 μM BAN and 900 μM CAN after 26 h post-treatment incubation resulted in DNA repair; however, subsequent cell cycle alteration effects were observed. Cell proliferation of HAN-treated cells was suppressed for as long as 43 to 52 h. Enlarged cell size was observed after 52 h post-treatment incubation without the induction of cytotoxicity. The HAN-mediated cell cycle alteration was mitosis- and proliferation-dependent, which suggests that HAN treatment induced mitosis override, and that HAN-treated cells proceeded into S phase and directly into the next cell cycle. Cells with multiples genomes would result in aneuploidy (state of abnormal chromosome number and DNA content) at the next mitosis since extra centrosomes could compromise the assembly of bipolar spindles. There is accumulating evidence of a transient tetraploid state proceeding to aneuploidy in cancer progression. Biological self-defense systems to ensure genomic stability and to eliminate tetraploid cells exist in eukaryotic cells. A key tumor suppressor gene, p53, is oftentimes mutated in various types of human cancer. It is possible that HAN disruption of the normal cell cycle and the generation of aberrant cells with an abnormal number of

  6. AN INTEGRATED RESEARCH AGENDA TO EVALUATE TAP WATER DISINFECTION BYPRODUCTS AND HUMAN HEALTH: PART 1

    EPA Science Inventory

    An Integrated Research Agenda to Evaluate Tap Water Disinfection Byproducts and Human Health: Part I

    Michele Lynberg1, David Ashley 2, Pauline Mendola3, J. R. Nuckols4, Kenneth Cantor5, Benjamin Blount 2, Philip Singer6, Charles Wilkes7, Lorraine Backer1, and Peter Langlo...

  7. RECOVERY OF MUTAGENICITY FROM DISINFECTED WATER BY XAD RESIN ADSORPTION COMPARED TO REVERSE OSMOSIS

    EPA Science Inventory

    Recovery of Mutagenicity from Disinfected Water Samples by XAD Resin Adsorption Compared to Reverse Osmosis

    K. M. Schenck1, T. F. Speth1, R. J. Miltner1, M. Sivaganesan1 and J. E. Simmons2

    1U.S. EPA, Office of Research and Development, NRMRL
    2U.S. EPA, Office of...

  8. EMERGING DISINFECTION BY-PRODUCTS OF TOXICOLOGICAL INTEREST: RESULTS OF A NATIONWIDE OCCURRENCE STUDY

    EPA Science Inventory

    The Safe Drinking Water Act and Amendments requires that EPA address disinfection by-products (DBPs) in drinking water. DBPs are formed when a disinfectant (such as chlorine) reacts with organic matter and/or bromide naturally present in source waters. Drinking water disinfecti...

  9. Hepatitis A Virus Disinfection in Water by Solar Photo-Fenton Systems.

    PubMed

    Polo, David; García-Fernández, Irene; Fernández-Ibañez, Pilar; Romalde, Jesús L

    2018-06-01

    This study evaluates and compares the effectiveness of solar photo-Fenton systems for the inactivation of hepatitis A virus (HAV) in water. The effect of solar irradiance, dark- Fenton reaction and three different reactant concentrations (2.5/5, 5/10 and 10/20 mg/L of Fe 2+ /H 2 O 2 ) on the photo-Fenton process were tested in glass bottle reactors (200 mL) during 6 h under natural sunlight. Disinfection kinetics were determined both by RT-qPCR and infectivity assays. Mean water temperatures ranged from 25 to 27.3 °C, with a maximum local noon UV irradiances of 22.36 W/m 2 . Photo-Fenton systems yielded increased viral reduction rates in comparison with the isolated effect under the Fenton reaction in darkness (negligible viral reduction) or the solar radiation (0.25 Log of RNA reduction). With the highest concentration employed (10-20 mg/L Fe 2+ -H 2 O 2 ), an average RNA reduction rate of ~ 1.8 Log (initial concentration of 10 5 pfu/mL) and a reduction of 80% in the infectivity capacity were reached. Results showed a strong synergistic effect between Fe 2+ /H 2 O 2 and sunlight, demonstrating that significant disinfection rates of HAV under photo-Fenton systems may occur with relatively higher efficiency at middle environmental temperatures and without the need for an energy-intensive light source.

  10. 40 CFR 141.541 - What are significant changes to disinfection practice?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 24 2012-07-01 2012-07-01 false What are significant changes to... (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Enhanced Filtration and... changes to disinfection practice? Significant changes to disinfection practice include: (a) Changes to the...

  11. 40 CFR 141.541 - What are significant changes to disinfection practice?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 23 2014-07-01 2014-07-01 false What are significant changes to... (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Enhanced Filtration and... changes to disinfection practice? Significant changes to disinfection practice include: (a) Changes to the...

  12. 40 CFR 141.541 - What are significant changes to disinfection practice?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 24 2013-07-01 2013-07-01 false What are significant changes to... (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Enhanced Filtration and... changes to disinfection practice? Significant changes to disinfection practice include: (a) Changes to the...

  13. 40 CFR 141.541 - What are significant changes to disinfection practice?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 23 2011-07-01 2011-07-01 false What are significant changes to... (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Enhanced Filtration and... changes to disinfection practice? Significant changes to disinfection practice include: (a) Changes to the...

  14. OVERVIEW OF RESEARCH ON DEFINED AND COMPLEX MIXTURES OF DISINFECTION BYPRODUCTS

    EPA Science Inventory

    Decreased morbidity and mortality from water-borne diseases are a direct result of water disinfection. Concurrent with these important public health benefits is low-level, chronic exposure to a very large number of disinfection byproducts (DBPs), chemicals formed as a result of ...

  15. Compliance Determination for Inactivation Requirements of the National Primary Drinking Water Regulations when a Public Water Systems Uses Dichlor and Trichlor for Primary Disinfection

    EPA Pesticide Factsheets

    This memorandum has been developed to assist SDWA primacy agencies (EPA Regions, states and territories) when considering inactivation/disinfection compliance requirements for those water systems that choose to use Dichlor or Trichlor.

  16. Survival of the faucet snail after chemical disinfection, pH extremes, and heated water bath treatments

    USGS Publications Warehouse

    Mitchell, A.J.; Cole, Rebecca A.

    2008-01-01

    The faucet snail Bithynia tentaculata, a nonindigenous aquatic snail from Eurasia, was introduced into Lake Michigan in 1871 and has spread to the mid-Atlantic states, the Great Lakes region, Montana, and most recently, the Mississippi River. The faucet snail serves as intermediate host for several trematodes that have caused large-scale mortality among water birds, primarily in the Great Lakes region and Montana. It is important to limit the spread of the faucet snail; small fisheries equipment can serve as a method of snail distribution. Treatments with chemical disinfection, pH extremes, and heated water baths were tested to determine their effectiveness as a disinfectant for small fisheries equipment. Two treatments eliminated all test snails: (1) a 24-h exposure to Hydrothol 191 at a concentration of at least 20 mg/L and (2) a treatment with 50°C heated water for 1 min or longer. Faucet snails were highly resistant to ethanol, NaCl, formalin, Lysol, potassium permanganate, copper sulfate, Baquacil, Virkon, household bleach, and pH extremes (as low as 1 and as high as 13).

  17. THE COMBINED CARCINOGENIC RISK FOR EXPOSURE TO MIXTURES OF DRINKING WATER DISINFECTION BY-PRODUCTS MAY BE LESS THAN ADDITIVE

    EPA Science Inventory

    The Combined Carcinogenic Risk for Exposure to Mixtures of Drinking Water Disinfection By-Products May be Less Than Additive

    Risk assessment methods for chemical mixtures in drinking water are not well defined. Current default risk assessments for chemical mixtures assume...

  18. Assessing exposure in epidemiologic studies to disinfection by-products in drinking water: report from an international workshop.

    PubMed Central

    Arbuckle, Tye E; Hrudey, Steve E; Krasner, Stuart W; Nuckols, Jay R; Richardson, Susan D; Singer, Philip; Mendola, Pauline; Dodds, Linda; Weisel, Clifford; Ashley, David L; Froese, Kenneth L; Pegram, Rex A; Schultz, Irvin R; Reif, John; Bachand, Annette M; Benoit, Frank M; Lynberg, Michele; Poole, Charles; Waller, Kirsten

    2002-01-01

    The inability to accurately assess exposure has been one of the major shortcomings of epidemiologic studies of disinfection by-products (DBPs) in drinking water. A number of contributing factors include a) limited information on the identity, occurrence, toxicity, and pharmacokinetics of the many DBPs that can be formed from chlorine, chloramine, ozone, and chlorine dioxide disinfection; b) the complex chemical interrelationships between DBPs and other parameters within a municipal water distribution system; and c) difficulties obtaining accurate and reliable information on personal activity and water consumption patterns. In May 2000, an international workshop was held to bring together various disciplines to develop better approaches for measuring DBP exposure for epidemiologic studies. The workshop reached consensus about the clear need to involve relevant disciplines (e.g., chemists, engineers, toxicologists, biostatisticians and epidemiologists) as partners in developing epidemiologic studies of DBPs in drinking water. The workshop concluded that greater collaboration of epidemiologists with water utilities and regulators should be encouraged in order to make regulatory monitoring data more useful for epidemiologic studies. Similarly, exposure classification categories in epidemiologic studies should be chosen to make results useful for regulatory or policy decision making. PMID:11834463

  19. 40 CFR 141.72 - Disinfection.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... serves water to the public. Water in the distribution system with a heterotrophic bacteria concentration... heterotrophic bacteria plate count (HPC) is measured; c=number of instances where the residual disinfectant... system with a heterotrophic bacteria concentration less than or equal to 500/ml, measured as...

  20. 40 CFR 141.72 - Disinfection.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... serves water to the public. Water in the distribution system with a heterotrophic bacteria concentration... heterotrophic bacteria plate count (HPC) is measured; c=number of instances where the residual disinfectant... system with a heterotrophic bacteria concentration less than or equal to 500/ml, measured as...

  1. Achieving long-term use of solar water disinfection in Zimbabwe.

    PubMed

    Mosler, H-J; Kraemer, S M; Johnston, R B

    2013-01-01

    To use a psychological theory of behavioural change to measure and interpret the effectiveness of different promotional strategies for achieving long-term usage of a household water treatment and safe storage (HWTS) system in peri-urban Zimbabwe. Solar disinfection (SODIS) was introduced into five peri-urban communities near Harare, Zimbabwe. Six different interventions were developed and were applied in four communities in different combinations, with the fifth remaining as a control area where no interventions were implemented. Throughout the 26 months of the study nine longitudinal panel surveys were conducted in which SODIS usage was estimated using three separate metrics: reported, calculated, and observed. A total of 1551 people were interviewed. The three indicators of SODIS usage broadly agreed with one another. By any measure, the most effective intervention was household visits by trained promoters in combination with persuasion. Households which received household visits maintained SODIS usage rates of 65% or more, even six months after the cessation of all promotional activities. Households receiving other interventions were significantly less effective. Interventions like prompts or public commitment after the application of household visits were effective at maintaining good practices once these were established. Household promotion in combination with persuasion appears more effective than other approaches, especially when followed with interventions targeting the maintenance of the new behaviour. With this intervention it is possible that around 65% of the households continue to use solar water disinfection (SODIS) more than two years after the initial promotion, and six months after the end of all interventions. Copyright © 2012 The Royal Society for Public Health. Published by Elsevier Ltd. All rights reserved.

  2. TOXICITY-BASED IDENTIFICATION OF DRINKING WATER DISINFECTION BY-PRODUCTS USING LC/MS AND LC/MS/MS

    EPA Science Inventory

    The goal of this research is to use a bio-assay directed approach to focus identification work on the most toxicologically important disinfection by-products. To this end, drinking water is being collected from full-scale treatment plants that use chlorine, ozone, chlorine dioxi...

  3. TOXICITY-BASED IDENTIFICATION OF DRINKING WATER DISINFECTION BY-PRODUCTS USING ESI-MS AND ESI-MS/MS

    EPA Science Inventory

    The goal of this research is to use a bio-assay directed approach to focus identification work on the most toxicologically important disinfection by-products. To this end, drinking water is being collected from full-scale treatment plants that use chlorine, ozone, chlorine dioxi...

  4. Effects of thermal treatment on halogenated disinfection by-products in drinking water.

    PubMed

    Wu, W W; Benjamin, M M; Korshin, G V

    2001-10-01

    The influence of heating or boiling on the formation and behavior of disinfection by-products (DBPs) was investigated in DBP-spiked reagent water, municipal tap water, and synthetic water containing chlorinated aquatic humic substances. Thermal cleavage of larger halogenated species leads to both formation of smaller chlorinated molecules (including THMs and HAAs) and dechlorination of organics. In parallel with their formation from larger molecules, THMs can be volatilized, and this latter process dominates the change in their concentration when water is boiled. HAAs are not volatile, but they can be destroyed by chemical reactions at elevated temperatures, with the net effect being loss of trihalogenated HAAs and either formation or loss of less chlorinated HAAs. Although other identifiable DBPs can be generated at slightly elevated temperatures, in most cases their concentrations decline dramatically when the solution is heated.

  5. MULTISPECTRAL IDENTIFICATION OF CHLORINE DIOXIDE DISINFECTION BY-PRODUCTS IN DRINKING WATER

    EPA Science Inventory

    This paper discusses the identification of organic disinfection by-products (DBPs) at a pilot plant in Evansville, Indiana, that uses chlorine dioxide as a primary disinfectant. nconventional multispectral identification techniques (gas chromatography combined with high and low r...

  6. 40 CFR 141.533 - What data must my system collect to calculate a disinfection profile?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... calculate a disinfection profile? 141.533 Section 141.533 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Enhanced Filtration and Disinfection-Systems Serving Fewer Than 10,000 People Disinfection Profile § 141.533 What data...

  7. GESTATIONAL AND LACTATIONAL EFFECTS IN RATS OF SODIUM, SULFATE, AND CONCENTRATED DISINFECTION BY-PRODUCTS IN DRINKING WATER

    EPA Science Inventory

    Epidemiological and animal toxicity studies have raised concerns regarding possible adverse health effects of disinfection by-products (DBPs) in drinking water (DW). Because many DBPs are unidentified, we sought to evaluate DW concentrates. In preparation for a multigenerational ...

  8. Disinfection Byproduct Formation in Reverse-Osmosis Concentrated and Lyophilized Natural Organic Matter from a Drinking Water Source

    EPA Science Inventory

    Drinking water treatment and disinfection byproduct (DBP) research can be complicated by natural organic matter (NOM) temporal variability. NOM preservation by lyophilization (freeze-drying) has been long practiced to address this issue; however, its applicability for drinking wa...

  9. Gestational and lactational effects in rats of sodium, sulfate, and concentrated disinfection by-products in drinking water

    EPA Science Inventory

    Epidemiological and animal toxicity studies have raised concerns regarding possible adverse health effects of disinfection by-products (DBPs) in drinking water (DW). Because many DBPs are unidentified, we sought to evaluate DW concentrates. In preparation for a multigenerational ...

  10. Community challenges when using large plastic bottles for Solar Energy Disinfection of Water (SODIS).

    PubMed

    Borde, Preeti; Elmusharaf, Khalifa; McGuigan, Kevin G; Keogh, Michael B

    2016-09-05

    Communities living in developing countries as well as populations affected by natural or man-made disasters can be left at great risk from water related diseases, especially those spread through the faecal-oral route. Conventional water treatments such as boiling and chlorination can be effective but may prove costly for impoverished communities. Solar water disinfection (SODIS) has been shown to be a cheap and effective way for communities to treat their water. The exposure to sunlight is typically carried out in small volume plastic beverage bottles (up to 2 l). Given the water requirements of consumption and basic personal hygiene, this may not always meet the needs of communities. Recent work has shown 19-L plastic water dispenser containers to be effective SODIS reactors, comparable in efficacy to PET bottles. In this paper we outline the need for studying SODIS in large volumes and discuss 4 main associated challenges. Apart from clean water needed for consumption, access to adequate water is essential for sanitation and hygiene. Contamination of treated water through unwashed hands or vessels contributes heavily to the spread of water borne pathogens in communities. Traditional water treatments such as boiling and chlorination can be effective but may prove financially burdensome for low income communities. SODIS in large vessels could be used as a simple method to meet water requirements in low income and disaster affected populations. However, there have been some concerns associated with the conventional SODIS method; we identify the main ones to be: (1) cold or cloudy weather; (2) the fear of leaching in plastic bottles; (3) water turbidity, and; (4) community acceptance. The application of SODIS in large bottles like WDCs has the potential to be an efficient and cost effective method of disinfecting water, either for consumption until more rigorous water treatments can be put in place, or for sanitation and hygiene to curb the spread of fecal

  11. Multi-functional magnetic water purifier for disinfection and removal of dyes and metal ions with superior reusability.

    PubMed

    Wu, Yao; Chen, Lei; Long, Xuwei; Zhang, Xiaolin; Pan, Bingcai; Qian, Jieshu

    2018-04-05

    It is of great practical importance but rarely reported to design a multifunctional scavenger for water purification. In this study, we describe a sophisticated preparation of an inorganic/organic composite sample for the simultaneous removal of anionic dyes and metal ions, as well as disinfection. The sample has a stable structure formed by the covalent connection between a magnetic silica (MS) core and a polyethylenimine derived quaternary ammonium compound (QAC) corona. We characterized the sample in details by SEM, TEM, EDX, FT-IR, XRD, TGA, VSM, and zeta potential. Our QAC-MS sample exhibited superior performance and reusability in the disinfection and adsorption experiments towards acid fuchsin and Cu 2+ . With the virtue of easy separation from solution, our sample should be an ideal candidate for water purification application. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. DEVELOPMENT OF A NOVEL METHOD FOR ANALYSIS OF TRANSCRIPTIONAL CHANGES IN TRANSITIONAL EPITHELIUM FROM URINARY BLADDERS OF RATS EXPOSED TO DRINKING WATER DISINFECTION BY-PRODUCTS

    EPA Science Inventory


    Development of a Novel Method for Analysis of Transcriptional Changes in Transitional Epithelium from Urinary Bladders of Rats Exposed to Drinking Water Disinfection By- products.

    Epidemiologic studies in human populations that drink chemically disinfected drinking wa...

  13. Electrochemical disinfection of coliform and Escherichia coli for drinking water treatment by electrolysis method using carbon as an electrode

    NASA Astrophysics Data System (ADS)

    Riyanto; Agustiningsih, W. A.

    2018-04-01

    Disinfection of coliform and E. Coli in water has been performed by electrolysis using carbon electrodes. Carbon electrodes were used as an anode and cathode with a purity of 98.31% based on SEM-EDS analysis. This study was conducted using electrolysis powered by electric field using carbon electrode as the anode and cathode. Electrolysis method was carried out using variations of time (30, 60, 90, 120 minutes at a voltage of 5 V) and voltage (5, 10, 15, 20 V for 30 minutes) to determine the effect of the disinfection of the bacteria. The results showed the number of coliform and E. coli in water before and after electrolysis was 190 and 22 MPN/100 mL, respectively. The standards quality of drinking water No. 492/Menkes/Per/IV/2010 requires the zero content of coliform and E. Coli. Electrolysis with the variation of time and potential can reduce the number of coliforms and E. Coli but was not in accordance with the standards. The effect of hydrogen peroxide (H2O2) to the electrochemical disinfection was determined using UV-Vis spectrophotometer. The levels of H2O2 formed increased as soon after the duration of electrolysis voltage but was not a significant influence to the mortality of coliform and E.coli.

  14. Research Issues Underlying the Four-Lab Study: Integrated Disinfection Byproducts Mixtures Research

    EPA Science Inventory

    Chemical disinfection of drinking water is a major public health triumph of the 20th century, resulting in significant decreases in morbidity and mortality from waterborne diseases. Disinfection byproducts (DBPs) are chemicals formed by the reaction of oxidizing disinfectants wi...

  15. Component-Based and Whole-Mixture Techniques for Addressing the Toxicity Of Drinking-Water Disinfection By-Product Mixtures

    EPA Science Inventory

    To conduct the health-effect studies described in subsequent articles, concentrated aqueous mixtures of disinfection byproducts were required for the two separate treatment trains described in the preceding article. To accomplish this, the finished drinking waters from each trea...

  16. Drinking Water Disinfection By-products, Genetic Polymorphisms, and Birth Outcomes in a European Mother-Child Cohort Study.

    PubMed

    Kogevinas, Manolis; Bustamante, Mariona; Gracia-Lavedán, Esther; Ballester, Ferran; Cordier, Sylvaine; Costet, Nathalie; Espinosa, Ana; Grazuleviciene, Regina; Danileviciute, Asta; Ibarluzea, Jesus; Karadanelli, Maria; Krasner, Stuart; Patelarou, Evridiki; Stephanou, Euripides; Tardón, Adonina; Toledano, Mireille B; Wright, John; Villanueva, Cristina M; Nieuwenhuijsen, Mark

    2016-11-01

    We examined the association between exposure during pregnancy to trihalomethanes, the most common water disinfection by-products, and birth outcomes in a European cohort study (Health Impacts of Long-Term Exposure to Disinfection By-Products in Drinking Water). We took into account exposure through different water uses, measures of water toxicity, and genetic susceptibility. We enrolled 14,005 mothers (2002-2010) and their children from France, Greece, Lithuania, Spain, and the UK. Information on lifestyle- and water-related activities was recorded. We ascertained residential concentrations of trihalomethanes through regulatory records and ad hoc sampling campaigns and estimated route-specific trihalomethane uptake by trimester and for whole pregnancy. We examined single nucleotide polymorphisms and copy number variants in disinfection by-product metabolizing genes in nested case-control studies. Average levels of trihalomethanes ranged from around 10 μg/L to above the regulatory limits in the EU of 100 μg/L between centers. There was no association between birth weight and total trihalomethane exposure during pregnancy (β = 2.2 g in birth weight per 10 μg/L of trihalomethane, 95% confidence interval = 3.3, 7.6). Birth weight was not associated with exposure through different routes or with specific trihalomethane species. Exposure to trihalomethanes was not associated with low birth weight (odds ratio [OR] per 10 μg/L = 1.02, 95% confidence interval = 0.95, 1.10), small-for-gestational age (OR = 0.99, 0.94, 1.03) and preterm births (OR = 0.98, 0.9, 1.05). We found no gene-environment interactions for mother or child polymorphisms in relation to preterm birth or small-for-gestational age. In this large European study, we found no association between birth outcomes and trihalomethane exposures during pregnancy in the total population or in potentially genetically susceptible subgroups. (See video abstract at http://links.lww.com/EDE/B104.).

  17. Optimum Disinfection Properties and Commercially Available Disinfectants

    DTIC Science & Technology

    1989-07-01

    organic constituents that display a chlorine demand.) d. Upon addition to water, the agent should dissolve quickly and release its active ingredient(s...trione pH dependence alkaline pH favored Temperature dependence high at low residual Palatability Taste and odor claimed to be lartgly absent Color...CryptosgortdLjM at various temperature and pH levels. 2. A field procedwu for masueing disinfectant residual is ".eded for chlorin dioaide. 3. Stability

  18. Novel AgNWs-PAN/TPU membrane for point-of-use drinking water electrochemical disinfection.

    PubMed

    Tan, Xiaojun; Chen, Chao; Hu, Yongyou; Wen, Junjie; Qin, Yanzhe; Cheng, Jianhua; Chen, Yuancai

    2018-10-01

    The safety of drinking water remains a major challenge in developing countries and point-of-use (POU) drinking water treatment device plays an important role in decentralised drinking water safety. In this study, a novel material, i.e. a silver nanowires-polyacrylonitrile/thermoplastic polyurethane (AgNWs-PAN/TPU) composite membrane, was fabricated via electrospinning and vacuum filtration deposition. Morphological and structural characterisation showed that the PAN/TPU fibres had uniform diameters and enhanced mechanical properties. When added to these fibres, the AgNWs formed a highly conductive network with good physical stability and low silver ion leaching (<100 ppb). A POU device equipped with a AgNWs-PAN/TPU membrane displayed complete removal of 10 5  CFU/mL bacteria, which were inactivated by silver ions released from the AgNWs within 6 h. Furthermore, under a voltage of 1.5 V, the bacteria were completely inactivated within 20-25 min. Inactivation efficiency in 5 mM NaCl solution was higher than those in Na 2 SO 4 and NaNO 3 solutions. We concluded that a strong electric field was formed at the AgNW tips. Additionally, silver ions and chlorine compounds worked synergistically in the disinfection process. This study provides a scientific basis for research and development of silver nanocomposite membranes, with high mechanical strength and high conductivity, for POU drinking water disinfection. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. Novel Electrokinetic Microfluidic Detector for Evaluating Effectiveness of Microalgae Disinfection in Ship Ballast Water

    PubMed Central

    Maw, Myint Myint; Wang, Junsheng; Li, Fabo; Jiang, Jinhu; Song, Younan; Pan, Xinxiang

    2015-01-01

    Ship ballast water treatment methods face many technical challenges. The effectiveness of every treatment method usually is evaluated by using large scale equipment and a large volume of samples, which involves time-consuming, laborious, and complex operations. This paper reports the development of a novel, simple and fast platform of methodology in evaluating the efficiency and the best parameters for ballast water treatment systems, particularly in chemical disinfection. In this study, a microfluidic chip with six sample wells and a waste well was designed, where sample transportation was controlled by electrokinetic flow. The performance of this microfluidic platform was evaluated by detecting the disinfection of Dunaliella salina (D. salina) algae in ballast water treated by sodium hypochlorite (NaClO) solution. Light-induced chlorophyll fluorescence (LICF) intensity was used to determine the viability of microalgae cells in the system, which can be operated automatically with the dimension of the detector as small as 50 mm × 24 mm × 5 mm. The 40 µL volume of sample solution was used for each treatment condition test and the validity of detection can be accomplished within about five min. The results show that the viability of microalgae cells under different treatment conditions can be determined accurately and further optimal treatment conditions including concentrations of NaClO and treatment time can also be obtained. These results can provide accurate evaluation and optimal parameters for ballast water treatment methods. PMID:26516836

  20. Case study approach to modeling historical disinfection by-product exposure in Iowa drinking waters.

    PubMed

    Krasner, Stuart W; Cantor, Kenneth P; Weyer, Peter J; Hildesheim, Mariana; Amy, Gary

    2017-08-01

    In the 1980s, a case-control epidemiologic study was conducted in Iowa (USA) to analyze the association between exposure to disinfection by-products (DBPs) and bladder cancer risk. Trihalomethanes (THMs), the most commonly measured and dominant class of DBPs in drinking water, served as a primary metric and surrogate for the full DBP mixture. Average THM exposure was calculated, based on rough estimates of past levels in Iowa. To reduce misclassification, a follow-up study was undertaken to improve estimates of past THM levels and to re-evaluate their association with cancer risk. In addition, the risk associated with haloacetic acids, another class of DBPs, was examined. In the original analysis, surface water treatment plants were assigned one of two possible THM levels depending on the point of chlorination. The re-assessment considered each utility treating surface or groundwater on a case-by-case basis. Multiple treatment/disinfection scenarios and water quality parameters were considered with actual DBP measurements to develop estimates of past levels. The highest annual average THM level in the re-analysis was 156μg/L compared to 74μg/L for the original analysis. This allowed the analysis of subjects exposed at higher levels (>96μg/L). The re-analysis established a new approach, based on case studies and an understanding of the water quality and operational parameters that impact DBP formation, for determining historical exposure. Copyright © 2017. Published by Elsevier B.V.