Water immersion decreases sympathetic skin response during color–word Stroop test
Yamazaki, Yudai; Takahashi, Akari; Uetake, Yoshihito; Nakano, Saki; Iguchi, Kaho; Baba, Yasuhiro; Nara, Rio; Shimoyama, Yoshimitsu
2017-01-01
Water immersion alters the autonomic nervous system (ANS) response in humans. The effect of water immersion on executive function and ANS responses related to executive function tasks was unknown. Therefore, this study aimed to determine whether water immersion alters ANS response during executive tasks. Fourteen healthy participants performed color–word-matching Stroop tasks before and after non-immersion and water immersion intervention for 15 min in separate sessions. The Stroop task-related skin conductance response (SCR) was measured during every task. In addition, the skin conductance level (SCL) and electrocardiograph signals were measured over the course of the experimental procedure. The main findings of the present study were as follows: 1) water immersion decreased the executive task-related sympathetic nervous response, but did not affect executive function as evaluated by Stroop tasks, and 2) decreased SCL induced by water immersion was maintained for at least 15 min after water immersion. In conclusion, the present results suggest that water immersion decreases the sympathetic skin response during the color–word Stroop test without altering executive performance. PMID:28742137
Water immersion decreases sympathetic skin response during color-word Stroop test.
Sato, Daisuke; Yamazaki, Yudai; Takahashi, Akari; Uetake, Yoshihito; Nakano, Saki; Iguchi, Kaho; Baba, Yasuhiro; Nara, Rio; Shimoyama, Yoshimitsu
2017-01-01
Water immersion alters the autonomic nervous system (ANS) response in humans. The effect of water immersion on executive function and ANS responses related to executive function tasks was unknown. Therefore, this study aimed to determine whether water immersion alters ANS response during executive tasks. Fourteen healthy participants performed color-word-matching Stroop tasks before and after non-immersion and water immersion intervention for 15 min in separate sessions. The Stroop task-related skin conductance response (SCR) was measured during every task. In addition, the skin conductance level (SCL) and electrocardiograph signals were measured over the course of the experimental procedure. The main findings of the present study were as follows: 1) water immersion decreased the executive task-related sympathetic nervous response, but did not affect executive function as evaluated by Stroop tasks, and 2) decreased SCL induced by water immersion was maintained for at least 15 min after water immersion. In conclusion, the present results suggest that water immersion decreases the sympathetic skin response during the color-word Stroop test without altering executive performance.
Synthetic sea water - An improved stress corrosion test medium for aluminum alloys
NASA Technical Reports Server (NTRS)
Humphries, T. S.; Nelson, E. E.
1973-01-01
A major problem in evaluating the stress corrosion cracking resistance of aluminum alloys by alternate immersion in 3.5 percent salt (NaCl) water is excessive pitting corrosion. Several methods were examined to eliminate this problem and to find an improved accelerated test medium. These included the addition of chromate inhibitors, surface treatment of specimens, and immersion in synthetic sea water. The results indicate that alternate immersion in synthetic sea water is a very promising stress corrosion test medium. Neither chromate inhibitors nor surface treatment (anodize and alodine) of the aluminum specimens improved the performance of alternate immersion in 3.5 percent salt water sufficiently to be classified as an effective stress corrosion test method.
Suizu, K; Harada, N
2005-05-01
To compare effects of waterproof covering on finger skin temperature (FST) and subjective hand pain during immersion tests using cold water at 10 degrees C, 12 degrees C and 15 degrees C. In the (Draft International Standard) of the International Organization for Standardization (ISO/DIS 14835-1), a water temperature of 12 degrees C and use of water covering are proposed. Six healthy male subjects took part in the immersion tests and immersed both hands into water at 10 degrees C, 12 degrees C and 15 degrees C for 5 min, repeatedly, with waterproof covering (polyethylene gloves) or without (bare hands). The FST data from middle fingers and subjective pain scores for hand pain were analyzed. Furthermore, the test with water at 12 degrees C was repeated to assess the repeatability of the test. The glove and water temperature factors for FST were significant at every minute from 1 min during immersion up to 2 min after recovery, showing higher values for waterproof covering than for bare hands and showing lowest values for water temperature of 10 degrees C and highest for 15 degrees C. The glove and water temperature factors for subjective pain score were significant at the 1-min and 2-min points during immersion, showing lower scores for waterproof covering than for bare hands and showing highest scores for water temperature of 10 degrees C and lowest for 15 degrees C. The results of the first and second tests using water of 12 degrees C showed no systematic difference in FST and hand pain between the tests, with a few exceptions. Subjective pain during the cold immersion test with polyethylene gloves and water at 12 degrees C can be reduced, while the differences in FST between water temperatures of 10 degrees C and 12 degrees C were small or not apparent at some points during immersion and recovery. The test also seems to be suitable for repeatability. Further investigation on hand-arm vibration syndrome (HAVS) patients to validate the use of the immersion test with gloves to obtain sufficient data for diagnostic value is required.
Influence of water immersion on the mechanical properties of fiber posts.
Komada, Wataru; Inagaki, Tasuku; Ueda, Yoji; Omori, Satoshi; Hosaka, Keiichi; Tagami, Junji; Miura, Hiroyuki
2017-01-01
The purpose of this study was to evaluate the influence of water immersion on the mechanical properties of three kinds of glass fiber posts and the fracture resistance of structures using resin composites with glass fiber posts. Each post was divided into three groups; a control group and two water immersion groups (30 and 90 days). Flexural strength was determined by three-point bending test. Each structure was divided into two groups; a control group and a water immersion group for 30 days. The fracture strength of structures was determined by a static loading test. In the flexural strength, two kinds of post in water immersion groups showed lower values than control groups. In the fracture strength, two kinds of structures in water immersion group showed lower values than control groups. The prefabricated glass fiber posts and structures using resin composites with glass fiber posts were affected by water immersion. Copyright © 2016 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.
Into hot water head first: distribution of intentional and unintentional immersion burns.
Daria, Sonya; Sugar, Naomi F; Feldman, Kenneth W; Boos, Stephen C; Benton, Scott A; Ornstein, Amy
2004-05-01
Experience with several, previously unreported, intentional face-first immersion burns led us to evaluate the distribution of inflicted and unintentional immersion scald burns in a hospital series. (1) Authors' clinical and legal practices; (2) Burn center at regional Level 1 trauma hospital. : (1) Case series of face-first, inflicted immersion burn victims; (2) Consecutive hospitalized scald burn victims younger than 5 years old, 1/3/1996 to 3/25/2000. (1) Individual case reports; (2) Retrospective records review. Simple descriptive statistics, Fisher Exact test and t test. (1) Six cases of inflicted head and neck immersion injury are described. Four were tap water and 2 food/drink scalds. (2) 22/195 hospitalized victims had sustained immersion burns, 13 from tap water and 9 from other fluids. Six (46%) tap water immersions and no (0%) other immersions had inflicted injuries (P = 0.05). Two of the tap water immersions and one other source immersion included burning of the head and neck. Of these, one tap water immersion, but no other immersion, was inflicted. In no patients were head and neck injuries the sole or predominant site of scalding. In all, 9 children sustained inflicted scalds. Bilateral lower extremity tap water immersion scalds occurred in 100% (6/6) of abusive and 29% (2/7) of unintentional injuries (P = 0.02). Buttock and perineal injuries occurred in 67% (4/6) inflicted versus 29% (2/7) unintentional tap water immersion scalds (P = 0.28). Other fluids caused bilateral lower extremity immersion burns in 3/9 (33 %) unintentionally injured patients, but no abused children (NS). Craniofacial immersion injury, although seen by the authors in legal cases, is infrequent. It was present incidentally in one inflicted tap water burn in the consecutive hospital series. This series affirms the predominance of bilateral lower extremity burns in inflicted tap water immersions. Buttock/perineal immersions were more common with abuse than with unintentional injury.
Bonding capacity of the GFRP-S on strengthened RC beams after sea water immersion
NASA Astrophysics Data System (ADS)
Sultan, Mufti Amir; Djamaluddin, Rudy
2017-11-01
Construction of concrete structures that located in extreme environments are such as coastal areas will result in decreased strength or even the damage of the structures. As well know, chloride contained in sea water is responsible for strength reduction or structure fail were hence maintenance and repairs on concrete structure urgently needed. One popular method of structural improvements which under investigation is to use the material Glass Fibre Reinforced Polymer which has one of the advantages such as corrosion resistance. This research will be conducted experimental studies to investigate the bonding capacity behavior of reinforced concrete beams with reinforcement GFRP-S immersed in sea water using immersion time of one month, three months, six months and twelve months. Test specimen consists of 12 pieces of reinforced concrete beams with dimensions (150x200x3000) mm that had been reinforced with GFRP-S in the area of bending, the beam without immersion (B0), immersion one month (B1), three months (B3), six months (B6) and twelve months (B12). Test specimen were cured for 28 days before the application of the GFRP sheet. Test specimen B1, B3, B6 and B12 that have been immersed in sea water pool with a immersion time each 1, 3, 6 and 12 months. The test specimen without immersion test by providing a static load until it reaches the failure, to record data during the test strain gauge mounted on the surface of the specimen and the GFRP to collect the strain value. From the research it obvious that there is a decrease bonding capacity on specimens immersed for one month, three months, six months and twelve months against the test object without immersion of 8.85%; 8.89%; 9.33% and 11.04%.
46 CFR 160.037-4 - Approval and production tests.
Code of Federal Regulations, 2013 CFR
2013-10-01
... signal plus packaging in a sealed plastic waterproof bag, the 24-hour water immersion conditioning will... discontinued production line. (2) Inspections and tests by the manufacturer. The manufacturer's quality control...: (i) Conditioning of test specimens—water resistance. Immerse specimen horizontally with uppermost...
46 CFR 160.037-4 - Approval and production tests.
Code of Federal Regulations, 2012 CFR
2012-10-01
... signal plus packaging in a sealed plastic waterproof bag, the 24-hour water immersion conditioning will... discontinued production line. (2) Inspections and tests by the manufacturer. The manufacturer's quality control...: (i) Conditioning of test specimens—water resistance. Immerse specimen horizontally with uppermost...
46 CFR 160.037-4 - Approval and production tests.
Code of Federal Regulations, 2014 CFR
2014-10-01
... signal plus packaging in a sealed plastic waterproof bag, the 24-hour water immersion conditioning will... discontinued production line. (2) Inspections and tests by the manufacturer. The manufacturer's quality control...: (i) Conditioning of test specimens—water resistance. Immerse specimen horizontally with uppermost...
Deconditioning-induced exercise responses as influenced by heat acclimation
NASA Technical Reports Server (NTRS)
Shvartz, E.; Bhattacharya, A.; Sperinde, S. J.; Brock, P. J.; Sciaraffa, D.; Haines, R. F.; Greenleaf, J. E.
1979-01-01
A study to determine the effect of heat acclimation and physical training in temperate conditions on changes in exercise tolerance following water-immersion deconditioning is presented. Five young men were tested on a bicycle ergometer before and after heat acclimation and after water immersion. The subjects and the experimental procedure, heat acclimation and exercise training, water immersion, and exercise tolerance are discussed. Heat acclimation resulted in the usual decreases in exercise heart rate and rectal temperature and an increase in sweat rate. Water immersion resulted in substantial diuresis despite water consumed. The results show that heat acclimation provides an effective method of preventing the adverse effects of water-immersion deconditioning on exercise tolerance.
Assessment of Marine Coatings at a Central California Static Immersion Test Site
2016-10-27
VA 220600-6218 RE: Contract Number N00014-15-1-2321 Assessment of Marine Coatings at a Central California Static Immersion Test Site Principal...Technical Report 05/01/2015 - 07/29/2016 Assessment of Marine Coatings at a Central California Static Immersion Test Site Dean E. Wendt Cal Poly...to test the relationships between the recruitment of fouling organisms to intersite panels and water quality parameters. The static immersion site
Influence of a peracetic acid-based immersion on indirect composite resin.
Samuel, Susana Maria Werner; Fracaro, Gisele Baggio; Collares, Fabrício Mezzomo; Leitune, Vicente Castelo Branco; Campregher, Ulisses Bastos
2011-06-01
The aim of this study was to evaluate the influence of immersion in a 0.2% peracetic acid-based disinfectant on the three-point flexural strength, water sorption and water solubility of an indirect composite resin. Specimens were produced according to ISO 4049:2000 specifications and were divided in two groups: Control group, with no disinfection and Disinfected group, with three 10 min immersions in the peracetic acid intercalated with 10 min immersions in sterile distilled water. All evaluations were conducted in compliance with ISO specifications. Three-point flexural strength, water sorption and solubility of indirect composite resin before and after immersion showed no statistical significant differences (p > 0.05) and met ISO standard requirements. Immersion in peracetic acid solution showed no influence in indirect composite resin tested properties.
Degradation of partially immersed glass: A new perspective
NASA Astrophysics Data System (ADS)
Chinnam, R. K.; Fossati, P. C. M.; Lee, W. E.
2018-05-01
The International Simple Glass (ISG) is a six-component borosilicate glass which was developed as a reference for international collaborative studies on high level nuclear waste encapsulation. Its corrosion behaviour is typically examined when it is immersed in a leaching solution, or when it is exposed to water vapour. In this study, an alternative situation is considered in which the glass is only partially immersed for 7 weeks at a temperature of 90 °C. In this case, half of the glass sample is directly in the solution itself, and the other half is in contact with a water film formed by condensation of water vapour that evaporated from the solution. This results in a different degradation behaviour compared to standard tests in which the material is fully immersed. In particular, whilst in standard tests the system reaches a steady state with a very low alteration rate thanks to the formation of a protective gel layer, in partially-immersed tests this steady state could not be reached because of the continuous alteration from the condensate water film. The constant input of ions from the emerged part of the sample caused a supersaturation of the solution, which resulted in early precipitation of secondary crystalline phases. This setup mimics storage conditions once small amounts of water have entered a glass waste form containing canister. It offers a more realistic outlook of corrosion mechanisms happening in such situations than standard fully-immersed corrosion tests.
Macedo, Christiane S G; Alonso, Carolina S; Liporaci, Rogério F; Vieira, Fernando; Guirro, Rinaldo R J
2014-01-01
Cryotherapy has been associated with a significant decrease in nerve conduction velocity and muscle contraction with possible effects on exercise and physical training. To quantify the electromyographic response of the lateral gastrocnemius, tibialis anterior, fibularis longus, rectus femoris and gluteus medius to ankle inversion following cold water immersion. The peak values of the root mean square (RMS) were obtained from 35 healthy and active university subjects after the use of a tilt platform to force the ankle into 30° of inversion before, immediately after, and 10, 20, and 30 minutes after water immersion at 4±2°C, for 20 minutes. The Shapiro-Wilk test, repeated measures analysis, Bonferroni's post-hoc, and linear regression analysis provided the results. Peak RMS was significantly lower at all times after cold water immersion, with residual effect of up to 30 minutes, when compared to pre-immersion for all muscles, except for immediate post-immersion for the gluteus medius. After cold water immersion of the ankle, special care should be taken in activities that require greater neuromuscular control.
Sasaki, Hirono; Hamanaka, Ippei; Takahashi, Yutaka; Kawaguchi, Tomohiro
2016-01-01
The purpose of this study was to investigate the effect of long-term water immersion or thermal shock on the mechanical properties of high-impact acrylic denture base resins. Two high-impact acrylic denture base resins were selected for the study. Specimens of each denture base material tested were fabricated according to the manufacturers' instructions (n=10). The flexural strength at the proportional limit, the elastic modulus and the impact strength of the specimens were evaluated. The flexural strength at the proportional limit of the high-impact acrylic denture base resins did not change after six months' water immersion or thermocycling 50,000 times. The elastic moduli of the high-impact acrylic denture base resins significantly increased after six months' water immersion or thermocycling 50,000 times. The impact strengths of the high-impact acrylic denture base resins significantly decreased after water immersion or thermocycling as described above.
Effect of longitudinal physical training and water immersion on orthostatic tolerance in men
NASA Technical Reports Server (NTRS)
Greenleaf, J. E.; Dunn, E. R.; Nesvig, C.; Keil, L. C.; Harrison, M. H.
1988-01-01
The effect of six months of moderately intense aerobic training on 60-deg head-up tilt tolerance was assessed before and after 6 hrs of water-immersion deconditioning by comparing the orthostatic and fluid-electrolyte-endocrine responses of five male subjects before and after these tests. It was found that six months of training has no significant effect on 60-deg head-up tilt tolerance. Thus, during pretraining, the water immersion tilt-tolerance was found to decrease from about 74 min before to 34 min after water immersion, while during posttraining, water immersion tilt tolerance decreased from 74 min to 44 min. Fluid-electrolyte-endocrine responses were also essentially the same during all four tilts. Plasma volume decreased by 9.0 to 12.6 percent; plasma sodium and osmotic concentrations were unchanged; and serum protein and plasma renin activity increased.
Rehman, Abdur; Amin, Faiza; Abbas, Muhammad
2014-11-01
To examine the effect of distilled water, artificial saliva and ethanol on the tensile strength of direct tooth-coloured restorative material. The study was conducted at Dr. Ishrat ul Ebad Khan Institute of Oral Health Sciences, Dow University of Health Sciences (DUHS), Karachi, from April 2011 to September 2012. The testing was performed at the Pakistan Council of Scientific and Industrial Research (PCSIR) laboratories. Two composite resins Filtek Z250 and Spectrum TPH were tested. Specimens (13 mm x 3 mm x 2 mm) of each material were prepared in the stainless steel mould according to the manufacturers' instructions and distributed into 3 equal groups: one immersed in distilled water, the other in artificial saliva, and the last one in ethanol for 24 hours. Tensile strength was determined after 24 hours in universal Instron Testing Machine. There were 72 specimens in all; 36 (50%) each for Filtek Z250 and Spectrum TPH. The three sub-groups in each case had 12 (33.3%) specimens. For the Filtek Z250, there was no statistically significant difference between immersion in distilled water and artificial saliva, but the ethanol group presented lower tensile strength (p<0.05). For the Spectrum TPH, samples immersed in ethanol and artificial saliva presented lower tensile strength compared to distilled water (p<0.05). The tested composite resins were affected by the immersion media and adversely affected the mechanical properties of composite resins.
Optimization of Energy Consumption and Mass Transfer Parameters in a Surface Aeration Vessel.
Mohammadpour, A; AkhavanBehabadi, M A; Ebrahimzadeh, M; Raisee, M; MajdiNasab, A R; Nosrati, M; Mousavi, S M
2016-04-01
This paper reports tests on a lab-scale surface aeration vessel was equipped with a Rushton turbine to examine its performance in terms of standard aeration efficiency (SAE), mixing time, and void fraction characteristics. These characteristics were investigated by tests using variations of rotor speed, impeller immersion depth, and water level. Results showed that variation of impeller immersion depth had a greater effect on the SAE compared to variation of water level. Moreover, the SAE increased with rotor speeds up to about 150 to 200 rpm and then decreased. In addition, void fraction improved by impeller immersion depth and rotor speed enhancement; however, mixing time and power number were reduced as rotor speed increased. According to the response surface methodology statistical optimizations, optimum values for rotor speed, impeller immersion depth, and water level were 168.90 rpm, 25 mm, and 30 cm, respectively, to achieve the maximum value of SAE.
Giesbrecht, Gordon G; Jamieson, Christopher; Cahill, Farrell
2007-06-01
Firefighters experience significant heat stress while working with heavy gear in a hot, humid environment. This study compared the cooling effectiveness of immersing the forearms and hands in 10 and 20 degrees C water. Six men (33 +/- 10 yr; 180 +/- 4 cm; 78 +/- 9 kg; 19 +/- 5% body fat) wore firefighter 'turn-out gear' (heavy clothing and breathing apparatus weighing 27 kg) in a protocol including three 20-min exercise bouts (step test, 78 W, 40 degrees C air, 40% RH) each followed by a 20-min rest/cooling (21 degrees C air); i.e., 60 min of exercise, 60 min of cooling. Turn-out gear was removed during rest/cooling periods and subjects either rested (Control), immersed their hands in 10 or 20 degrees C water (H-10, H-20), or immersed their hands and forearms in 10 or 20 degrees C water (HF-10, HF-20). In 20 degrees C water, hand immersion did not reduce core temperature compared with Control; however, including forearm immersion decreased core temperature below Control values after both the second and final exercise periods (p < 0.001). In 10 degrees C water, adding forearm with hand immersion produced a lower core temperature (0.8 degrees C above baseline) than all other conditions (1.1 to 1.4 degrees C above baseline) after the final exercise period (p < 0.001). Sweat loss during Control (1458 g) was greater than all active cooling protocols (1146 g) (p < 0.001), which were not different from each other. Hand and forearm immersion in cool water is simple, reduces heat strain, and may increase work performance in a hot, humid environment. With 20 degrees C water, forearms should be immersed with the hands to be effective. At lower water temperatures, forearm and/or hand immersion will be effective, although forearm immersion will decrease core temperature further.
NEPPELENBROEK, Karin Hermana; KUROISHI, Eduardo; HOTTA, Juliana; MARQUES, Vinicius Rizzo; MOFFA, Eduardo Buozi; SOARES, Simone; URBAN, Vanessa Migliorini
2015-01-01
Objective To evaluate the effect of staining beverages (coffee, orange juice, and red wine) on the Vickers hardness and surface roughness of the base (BL) and enamel (EL) layers of improved artificial teeth (Vivodent and Trilux). Material and Methods Specimens (n=8) were stored in distilled water at 37°C for 24 h and then submitted to the tests. Afterwards, specimens were immersed in one of the staining solutions or distilled water (control) at 37°C, and the tests were also performed after 15 and 30 days of immersion. Data were analyzed using 3-way ANOVA and Tukey’s test (α=0.05). Results Vivodent teeth exhibited a continuous decrease (p<0.0005) in hardness of both layers for up to 30 days of immersion in all solutions. For Trilux teeth, similar results were found for the EL (p<0.004), and the BL showed a decrease in hardness after 15 days of immersion (p<0.01). At the end of 30 days, this reduction was not observed for coffee and water (p>0.15), but red wine and orange juice continuously reduced hardness values (p<0.0004). Red wine caused the most significant hardness changes, followed by orange juice, coffee, and water (p<0.006). No significant differences in roughness were observed for both layers of the teeth during the immersion period, despite the beverage (p>0.06). Conclusions Hardness of the two brands of acrylic teeth was reduced by all staining beverages, mainly for red wine. Roughness of both layers of the teeth was not affected by long-term immersion in the beverages. PMID:26398509
The role of nervus intermedius in side specific nasal responses.
Nichani, J R; Malik, V; Woolford, T J; Ramsden, R T; Homer, J J
2010-03-02
Nervus intermedius (NI) dysfunction is common in patients who have had vestibular schwannoma (VS) surgery. Such patients have a unilateral parasympathetic-denervated nasal cavity. A number of side-specific nasal reflexes have been demonstrated in normal individuals, including hand cold-water immersion. It is not understood whether these reflexes have parasympathetic or sympathic efferent pathways. We aimed to evaluate the side specific nasal reflex to cold-water immersion in post-operative VS patients with NI dysfunction, in order to determine the nature of the efferent pathway of these reflexes. Side specific responses to cold-water immersion were tested by acoustic rhinometry in 10 normal individuals and 18 patients with NI dysfunction (proven by Schirmer s test) after VS surgery. A consistent pattern of ipsilateral congestion and contralateral decongestion after the cold-water immersion was seen in normal individuals (p smaller than 0.001). We found no consistent response in VS patients both ipsilateral and contralateral to the side of NI dysfunction. We confirm the consistent side-specific nasal reflexes to cold-water hand immersion in normal individuals. This is disturbed in patients with NI dysfunction. We have also shown unexpectantly that the contralateral side-specific reflex is disturbed in these patients. These data suggest that the reflex is parasympathetic and crosses the midline.
Breath-hold times in air compared to breath-hold times during cold water immersions.
Taber, Michael J; MacKinnon, Scott N; Power, Jonathan; Walker, Robert
2015-02-01
Given the effects of cold water immersion on breath-hold (BH) capabilities, a practical training exercise was developed for military/paramilitary personnel completing a helicopter underwater egress training (HUET) program. The exercise was designed to provide firsth and experience of the effects of cold water exposure on BH time. After completing the required HUET, 47 subjects completed two BH testing sessions as well as a short questionnaire. The first BH was completed while standing on the pool deck. The second BH was completed while fully immersed (face down) in 2-3°C water. There were 40 of the volunteers who also breathed from an emergency breathing system (EBS) while in the cold water. Results demonstrated that BH capabilities in cold water were significantly lower than those in ambient air. A significant correlation was also found between BH in air and the difference in cold water vs. air BH capabilities, which suggests that subjects who can hold their breath the longest in air experienced the greatest decrease in BH when immersed. Results indicate that 92% of the subjects reported that the practical cold water immersion exercise had a high value. Finally, 58% of those who used the EBS reported that it was harder to breathe in cold water than while in the training pool (approximately 22°C). The BH times for this group were similar to those reported in previous cold water immersion studies. Based on the questionnaire results, it is possible, when carefully applied, to include a practical cold water immersion exercise into existing HUET programs.
46 CFR 160.171-17 - Approval testing for adult size immersion suit.
Code of Federal Regulations, 2013 CFR
2013-10-01
... equivalent synthetic socks; (v) Work shoes, if the suit is designed for shoes to be worn inside. (2) Test... Approval testing for adult size immersion suit. Caution: During each of the in-water tests prescribed in... if the oversize adult suit is of the same design as the adult suit except for extra material to...
Stocks, J M; Patterson, M J; Hyde, D E; Jenkins, A B; Mittleman, K D; Taylor, N A S
2004-06-01
We investigated the impact of cold-water acclimation on whole-body fluid regulation using tracer-dilution methods to differentiate between the intracellular and extracellular fluid compartments. Seven euhydrated males [age 24.7 (8.7) years, mass 74.4 (6.4) kg, height 176.8 (7.8) cm, sum of eight skinfolds 107.4 (20.4) mm; mean (SD)] participated in a 14-day cold-water acclimation protocol, with 60-min resting cold-water stress tests [CWST; 18.1 (0.1) degrees C] on days 1, 8 and 15, and 90-min resting cold-water immersions [18.4 (0.4) degrees C] on intervening days. Subjects were immersed to the 4th intercostal space. Intracellular and extracellular fluid compartments, and plasma protein, electrolyte and hormone concentrations were investigated. During the first CWST, the intracellular fluid (5.5%) and plasma volumes were reduced (6.1%), while the interstitial fluid volume was simultaneously expanded (5.4%). This pattern was replicated on days 8 and 15, but did not differ significantly among test days. Acclimation did not produce significant changes in the pre-immersion distribution of total body water, or changes in plasma osmolality, total protein, electrolyte, atrial natriuretic peptide or aldosterone concentrations. Furthermore, a 14-day cold-water acclimation regimen did not elicit significant changes in body-fluid distribution, urine production, or the concentrations of plasma protein, electrolytes or the fluid-regulatory hormones. While acclimation trends were not evident, we have confirmed that fluid from extravascular cells is displaced into the interstitium during acute cold-water immersion, both before and after cold acclimation.
Comparison of the Effect of two Denture Cleansers on Tensile bond Strength of a Denture Liner.
Farzin, M; Bahrani, F; Adelpour, E
2013-09-01
One of the most clinical challenging issues in prosthodontics is debonding of soft liners from the denture base. The aim of this study was to evaluate and compare tensile bond strength between soft liner and heat-cured acrylic resin when immersed in two different types of denture cleanser and distilled water, at different period of times. In this experimental in vivo study, 238 heat-cured acrylic blocks were made. A soft liner was embedded between the acrylic blocks. Samples were divided into four groups: 17 samples were in the control group and were not soaked in any solution .The remaining samples were divided into 3 groups (Distilled water, Calgon and Fittydent). Each group was then subdivided into two subcategories, regarding the immersion time variable; 15 and 45 minutes. All samples were placed in tension force and tensile bond strength was recorded with the testing machine. One- way ANOVA and Tucky HSD post-hoc test were adopted to analyze the yielded data (α> 0.05). Specimens which were immersed in two denture cleansers (Fittydent and Calgon) and in distilled water showed significant difference (p= 0.001) in bonding strength when compared to the control group. The subjects immersed in denture cleanser solutions and distilled water did not reveal any significant difference (p= 0.90). For all groups; most of the bonding failures (72%) were cohesive type. The effect of the denture cleansers and distilled water on the bond strength was not statistically different; however, the difference was significant between the immersed groups with the non-immersed group. Moreover, type of the denture cleanser did not show any effect on the tensile strength. The tensile strength increases with time of immersion.
Blood volume reduction counteracts fluid shifts in water immersion
NASA Technical Reports Server (NTRS)
Simanonok, Karl E.; Bernauer, Edmund
1993-01-01
Six healthy men were bled by 15 percent of their total blood volume (TBV) before 7 h of seated water immersion, to test the hypothesis that some of the major physiological responses to an expansion of central blood volume can be counteracted by prior reduction of TBV. Subjects were their own controls under two conditions: seated dry in air and seated immersed to the suprasternal notch in water. Immersion without prior reduction of TBV Wet Control (WC) caused a statistically significant 22-percent increase in cardiac output (CO), 368-percent increase in urine production, and 200-percent increase in sodium excretion relative to dry control (DC) sessions. When TBV was reduced before immersion, CO was the same as during DC sessions; however there were significant increases above DC in urine flow (+73 percent) and sodium excretion (+120 percent), although they were significantly reduced from WC values. Potassium excretion was similar during DC and WC sessions, but was significantly increased (+75 percent) when subjects were immersed after 15-percent reduction of TBV.
Chow, Gary C C; Yam, Timothy T T; Chung, Joanne W Y; Fong, Shirley S M
2017-02-01
This single-blinded, three-armed randomized controlled trial aimed to compare the effects of postexercise ice-water immersion (IWI), room-temperature water immersion (RWI), and no water immersion on the balance performance and knee joint proprioception of amateur rugby players. Fifty-three eligible amateur rugby players (mean age ± standard deviation: 21.6 ± 2.9 years) were randomly assigned to the IWI group (5.3 °C), RWI group (25.0 °C), or the no immersion control group. The participants in each group underwent the same fatigue protocol followed by their allocated recovery intervention, which lasted for 1 minute. Measurements were taken before and after the fatigue-recovery intervention. The primary outcomes were the sensory organization test (SOT) composite equilibrium score (ES) and the condition-specific ES, which were measured using a computerized dynamic posturography machine. The secondary outcome was the knee joint repositioning error. Two-way repeated measures analysis of variance was used to test the effect of water immersion on each outcome variable. There were no significant within- and between-group differences in the SOT composite ESs or the condition-specific ESs. However, there was a group-by-time interaction effect on the knee joint repositioning error. It seems that participants in the RWI group had lower errors over time, but those in the IWI and control groups had increased errors over time. The RWI group had significantly lower error score than the IWI group at postintervention. One minute of postexercise IWI or RWI did not impair rugby players' sensory organization of balance control. RWI had a less detrimental effect on knee joint proprioception to IWI at postintervention.
Chow, Gary C.C.; Yam, Timothy T.T.; Chung, Joanne W.Y.; Fong, Shirley S.M.
2017-01-01
Abstract Background: This single-blinded, three-armed randomized controlled trial aimed to compare the effects of postexercise ice-water immersion (IWI), room-temperature water immersion (RWI), and no water immersion on the balance performance and knee joint proprioception of amateur rugby players. Methods: Fifty-three eligible amateur rugby players (mean age ± standard deviation: 21.6 ± 2.9 years) were randomly assigned to the IWI group (5.3 °C), RWI group (25.0 °C), or the no immersion control group. The participants in each group underwent the same fatigue protocol followed by their allocated recovery intervention, which lasted for 1 minute. Measurements were taken before and after the fatigue-recovery intervention. The primary outcomes were the sensory organization test (SOT) composite equilibrium score (ES) and the condition-specific ES, which were measured using a computerized dynamic posturography machine. The secondary outcome was the knee joint repositioning error. Two-way repeated measures analysis of variance was used to test the effect of water immersion on each outcome variable. Results: There were no significant within- and between-group differences in the SOT composite ESs or the condition-specific ESs. However, there was a group-by-time interaction effect on the knee joint repositioning error. It seems that participants in the RWI group had lower errors over time, but those in the IWI and control groups had increased errors over time. The RWI group had significantly lower error score than the IWI group at postintervention. Conclusion: One minute of postexercise IWI or RWI did not impair rugby players’ sensory organization of balance control. RWI had a less detrimental effect on knee joint proprioception to IWI at postintervention. PMID:28207546
Armstrong, John W; Follett, Peter A
2007-08-01
Immersion of litchi fruit in 49 degrees C water for 20 min followed by hydrocooling in ambient (24 +/- 4 degrees C) temperature water for 20 min was tested as a quarantine treatment against potential infestations of Mediterranean fruit fly, Ceratitis capitata (Wiedemann); and oriental fruit fly, Bactrocera dorsalis Hendel, eggs or larvae in Hawaiian litchi, Litchi chinensis Sonnerat. The 49 degrees C hot-water immersion of litchi provided probit 9 (99.9968% mortality with >95% confidence) quarantine security against eggs and first instars. There were no survivors from 15,000 each feeding and nonfeeding Mediterranean fruit fly or oriental fruit fly third instars immersed in a computer-controlled water bath that simulated the litchi seed-surface temperature profile during the 49 degrees C hot-water immersion treatment. Litchi served as the model for longan, Dimocarpus longan Lour., a closely related fruit that is smaller and also has commercial potential for Hawaii. Modified fruit infestation and holding techniques used to obtain adequate estimated treated populations from poor host fruit, such as litchi and longan, are described. Data from these experiments were used to obtain approval of a hot-water immersion quarantine treatment against fruit flies for litchi and longan exported from Hawaii to the U.S. mainland.
Macedo, Christiane de Souza Guerino; Vicente, Rafael Chagas; Cesário, Mauricio Donini; Guirro, Rinaldo Roberto de Jesus
2016-01-01
The purpose of this study was to evaluate the effects of cold-water immersion on the electromyographic (EMG) response of the lower limb and balance during unipodal jump landing. The evaluation comprised 40 individuals (20 basketball players and 20 non-athletes). The EMG response in the lateral gastrocnemius, tibialis anterior, fibular longus, rectus femoris, hamstring and gluteus medius; amplitude and mean speed of the centre of pressure, flight time and ground reaction force (GRF) were analysed. All volunteers remained for 20 min with their ankle immersed in cold-water, and were re-evaluated immediately post and after 10, 20 and 30 min of reheating. The Shapiro-Wilk test, Friedman test and Dunn's post test (P < 0.05) were used. The EMG response values decreased for the lateral gastrocnemius, tibialis anterior, fibular longus and rectus femoris of both athletes and non-athletes (P < 0.05). The comparison between the groups showed that the EMG response was lower for the athletes. Lower jump flight time and GRF, greater amplitude and mean speed of centre of pressure were predominant in the athletes. Cold-water immersion decreased the EMG activity of the lower limb, flight time and GRF and increased the amplitude and mean speed of centre of pressure.
The effect of ethnicity on the vascular responses to cold exposure of the extremities.
Maley, Matthew J; Eglin, Clare M; House, James R; Tipton, Michael J
2014-11-01
Cold injuries are more prevalent in individuals of African descent (AFD). Therefore, we investigated the effect of extremity cooling on skin blood flow (SkBF) and temperature (T sk) between ethnic groups. Thirty males [10 Caucasian (CAU), 10 Asian (ASN), 10 AFD] undertook three tests in 30 °C air whilst digit T sk and SkBF were measured: (i) vasomotor threshold (VT) test--arm immersed in 35 °C water progressively cooled to 10 °C and rewarmed to 35 °C to identify vasoconstriction and vasodilatation; (ii) cold-induced vasodilatation (CIVD) test--hand immersed in 8 °C water for 30 min followed by spontaneous warming; (iii) cold sensitivity (CS) test--foot immersed in 15 °C water for 2 min followed by spontaneous warming. Cold sensory thresholds of the forearm and finger were also assessed. In the VT test, vasoconstriction and vasodilatation occurred at a warmer finger T sk in AFD during cooling [21.2 (4.4) vs. 17.0 (3.1) °C, P = 0.034] and warming [22.0 (7.9) vs. 12.1 (4.1) °C, P = 0.002] compared with CAU. In the CIVD test, average SkBF during immersion was greater in CAU [42 (24) %] than ASN [25 (8) %, P = 0.036] and AFD [24 (13) %, P = 0.023]. Following immersion, SkBF was higher and rewarming faster in CAU [3.2 (0.4) °C min(-1)] compared with AFD [2.5 (0.7) °C min(-1), P = 0.037], but neither group differed from ASN [3.0 (0.6) °C min(-1)]. Responses to the CS test and cold sensory thresholds were similar between groups. AFD experienced a more intense protracted finger vasoconstriction than CAU during hand immersion, whilst ASN experienced an intermediate response. This greater sensitivity to cold may explain why AFD are more susceptible to cold injuries.
Hybrid water immersion simulation of manual IVA performance in weightlessness
NASA Technical Reports Server (NTRS)
Loats, H. L., Jr.; Mattingly, G. S.
1971-01-01
A description is given of the development, tests, and analysis of a manual simulator. The simulator was developed to test mass handling and translation under weightlessness conditions by a test subject. The system is composed of a hybrid simulator with a combination of water immersion and mechanical, Peter Pan, simulation. The concept operates on the equivalence principle, with the subject and the cargo remaining quasi-stationary. Movement is effected through a moving device controlled through force by the subject. Motion response is determined through computations of the inertial movement under such conditions.
Clements, Julie M.; Casa, Douglas J.; Knight, J. Chad; McClung, Joseph M.; Blake, Alan S.; Meenen, Paula M.; Gilmer, Allison M.; Caldwell, Kellie A.
2002-01-01
Objective: To assess whether ice-water immersion or cold-water immersion is the more effective treatment for rapidly cooling hyperthermic runners. Design and Setting: 17 heat-acclimated highly trained distance runners (age = 28 ± 2 years, height = 180 ± 2 cm, weight = 68.5 ± 2.1 kg, body fat = 11.2 ± 1.3%, training volume = 89 ± 10 km/wk) completed a hilly trail run (approximately 19 km and 86 minutes) in the heat (wet-bulb globe temperature = 27 ± 1°C) at an individually selected “comfortable” pace on 3 occasions 1 week apart. The random, crossover design included (1) distance run, then 12 minutes of ice-water immersion (5.15 ± 0.20°C), (2) distance run, then 12 minutes of cold-water immersion (14.03 ± 0.28°C), or (3) distance run, then 12 minutes of mock immersion (no water, air temperature = 28.88 ± 0.76°C). Measurements: Each subject was immersed from the shoulders to the hip joints for 12 minutes in a tub. Three minutes elapsed between the distance run and the start of immersion. Rectal temperature was recorded at the start of immersion, at each minute of immersion, and 3, 6, 10, and 15 minutes postimmersion. No rehydration occurred during any trial. Results: Length of distance run, time to complete distance run, rectal temperature, and percentage of dehydration after distance run were similar (P > .05) among all trials, as was the wet-bulb globe temperature. No differences (P > .05) for cooling rates were found when comparing ice-water immersion, cold-water immersion, and mock immersion at the start of immersion to 4 minutes, 4 to 8 minutes, and the start of immersion to 8 minutes. Ice-water immersion and cold-water immersion cooling rates were similar (P > .05) to each other and greater (P < .05) than mock immersion at 8 to 12 minutes, the start of immersion to 10 minutes, and the start of immersion to every other time point thereafter. Rectal temperatures were similar (P > .05) between ice-water immersion and cold-water immersion at the completion of immersion and 15 minutes postimmersion, but ice-water immersion rectal temperatures were less (P < .05) than cold-water immersion at 6 and 10 minutes postimmersion. Conclusions: Cooling rates were nearly identical between ice-water immersion and cold-water immersion, while both were 38% more effective in cooling after 12 minutes of immersion than the mock-immersion trial. Given the similarities in cooling rates and rectal temperatures between ice-water immersion and cold-water immersion, either mode of cooling is recommended for treating the hyperthermic individual. PMID:12937427
Lockhart, Tamara L; Jamieson, Christopher P; Steinman, Alan M; Giesbrecht, Gordon G
2005-10-01
Personal floatation devices (PFDs) differ in whether they maintain the head out of the water or allow the dorsum of the head to be immersed. Partial head submersion may hasten systemic cooling, incapacitation, and death in cold water. Six healthy male volunteers (mean age = 26.8 yr; height = 184 cm; weight = 81 kg; body fat = 20%) were immersed in 10 degrees C water for 65 min, or until core temperature = 34 degrees C, under three conditions: PFD#1 maintained the head and upper chest out of the water; PFD#2 allowed the dorsal head and whole body to be immersed; and an insulated drysuit (control) allowed the dorsal head to be immersed. Mental performance tests included: logic reasoning test; Stroop word-color test; digit symbol coding; backward digit span; and paced auditory serial addition test (PASAT). Core cooling was significantly faster for PFD#2 (2.8 +/- 1.6 degrees C x h(-1)) than for PFD#1 (1.5 +/- 0.7 degrees C x h(-1)) or for the drysuit (0.4 +/- 0.2 degrees C x h(-1)). Although no statistically significant effects on cognitive performance were noted for the individual PFDs and drysuit, when analyzed as a group, four of the tests of cognitive performance (Stroop word-color, digit symbol coding, backward digit span, and PASAT) showed significant correlations between decreasing core temperature to 34 degrees C and diminished cognitive performance. Performance in more complicated mental tasks was adversely affected as core temperature decreased to 34 degrees C. The PFD that kept the head and upper chest out of the water preserved body heat and mental performance better than the PFD that produced horizontal flotation.
NASA Astrophysics Data System (ADS)
Mostavi, Amir; Tehrani, N.; Kamali, N.; Ozevin, D.; Chi, S. W.; Indacochea, J. E.
2017-02-01
This article investigates water coupled nonlinear ultrasonic method to measure the dislocation density in aluminum 1100 specimens. The different levels of dislocation densities are introduced to the samples by applying different levels of plastic strains by tensile loading. The ultrasonic testing includes 2.25 MHz transducer as transmitter and 5.0 MHz transducer as receiver in an immersion tank. The results of immersion experiments are compared with oil-coupled experiments. While water has significant nonlinearity within itself, the immersion ultrasound results agree with the literature of oil coupled ultrasound results of the specimens that the nonlinearity coefficient increases with the increase of dislocation density in aluminum.
The effect of disinfectant solutions on the hardness of acrylic resin denture teeth.
Pavarina, A C; Vergani, C E; Machado, A L; Giampaolo, E T; Teraoka, M T
2003-07-01
This investigation studied the effects of disinfectant solutions on the hardness of acrylic resin denture teeth. The occlusal surfaces of 64 resin denture teeth were ground flat with abrasives up to 400-grit silicon carbide paper. Measurements were made after polishing and after the specimens were stored in water at 37 degrees C for 48 h. The specimens were then divided into four groups and immersed in chemical disinfectants (4% chlorhexidine; 1% sodium hypochlorite and sodium perborate) for 10 min. The disinfection methods were performed twice to simulate clinical conditions and hardness measurements were made. Specimens tested as controls were immersed in water during the same disinfection time. Eight specimens were produced for each group. After desinfection procedures, testing of hardness was also performed after the samples were stored at 37 degrees C for 7, 30, 60, 90 and 120 days. Data were analysed using two-way analysis of variance (anova) and Tukey's test at 95% confidence level. According to the results, no significant differences were found between materials and immersion solutions (P > 0.05). However, a continuous decrease in hardness was noticed after ageing (P < 0.05). It was conclude that the surfaces of both acrylic resin denture teeth softened upon immersion in water regardless the disinfecting solution.
Effects of water immersion to the neck on pulmonary circulation and tissue volume in man
NASA Technical Reports Server (NTRS)
Begin, R.; Epstein, M.; Sackner, M. A.; Levinson, R.; Dougherty, R.; Duncan, D.
1976-01-01
A rapid noninvasive breathing method is used to obtain serial measurements of the pulmonary capillary blood flow, diffusing capacity per unit of alveolar volume, combined pulmonary tissue plus capillary volume, functional residual capacity, and oxygen consumption in five normal subjects undergoing 6 h of sitting, 4 h of sitting while immersed to the neck in thermoneutral water, and 4 h of lying in thermoneutral water to the neck. The rebreathing method employed a test gas mixture containing 0.5% C2H2, 0.3% C(18)O, 10% He, 21% O2, and balance N2. It is shown that immersion to the neck in the seated posture results in significant increases in sodium excretion cardiac output, and diffusing capacity per unit of alveolar volume. The pulmonary tissue plus capillary volume did not change, demonstrating that the central vascular engorgement induced by water immersion is not accompanied by significant extravasation of fluid into the pulmonary interstitial space.
Schmid, Jean‐Paul; Noveanu, Markus; Morger, Cyrill; Gaillet, Raymond; Capoferri, Mauro; Anderegg, Matthias; Saner, Hugo
2007-01-01
Background Whole‐body water immersion leads to a significant shift of blood from the periphery to the intrathoracic circulation, followed by an increase in central venous pressure and heart volume. In patients with severely reduced left ventricular function, this hydrostatically induced volume shift might overstrain the cardiovascular adaptive mechanisms and lead to cardiac decompensation. Aim To assess the haemodynamic response to water immersion, gymnastics and swimming in patients with chronic heart failure (CHF). Methods 10 patients with compensated CHF (62.9 (6.3) years, ejection fraction 31.5% (4.1%), peak oxygen consumption (V̇o2) 19.4 (2.8) ml/kg/min), 10 patients with coronary artery disease (CAD) but preserved left ventricular function (57.2 (5.6) years, ejection fraction 63.9% (5.5%), peak V̇o2 28 (6.3) ml/kg/min), and 10 healthy controls (32.8 (7.2) years, peak V̇o2 45.6 (6) ml/kg/min) were examined. Haemodynamic response to thermoneutral (32°C) water immersion and exercise was measured using a non‐invasive foreign gas rebreathing method during stepwise water immersion, water gymnastics and swimming. Results Water immersion up to the chest increased cardiac index by 19% in controls, by 21% in patients with CAD and by 16% in patients with CHF. Although some patients with CHF showed a decrease of stroke volume during immersion, all subjects were able to increase cardiac index (by 87% in healthy subjects, by 77% in patients with CAD and by 53% in patients with CHF). V̇o2 during swimming was 9.7 (3.3) ml/kg/min in patients with CHF, 12.4 (3.5) ml/kg/min in patients with CAD and 13.9 (4) ml/kg/min in controls. Conclusions Patients with severely reduced left ventricular function but stable clinical conditions and a minimal peak V̇o2 of at least 15 ml/kg/min during a symptom‐limited exercise stress test tolerate water immersion and swimming in thermoneutral water well. Although cardiac index and V̇o2 are lower than in patients with CAD with preserved left ventricular function and controls, these patients are able to increase cardiac index adequately during water immersion and swimming. PMID:17164483
Shul'zhenko, E B; Kozlova, V G; Kurdin, K A; Iarov, A S; Plokhova, V G
1983-01-01
Orthostatic tolerance after 7-day dry immersion and head-to-feet acceleration was investigated on test subjects with and without an antigravity suit of bladderless type. With the suit on, the 20 min tilt test at 70 degrees prior to immersion induced less marked changes than without the suit. When the suit was on, cardiovascular reactions to tilt tests after immersion and acceleration improved. The maximum heart rate decreased from 135 +/- 4 to 101 +/- 5 beats/min (p less than 0.01), minimum stroke volume increased from 29 +/- 2 to 41 +/- 3 ml (p less than 0.05), and pulse pressure grew. Thus, an antigravity suit may help increase initial orthostatic tolerance and maintain it after the combined effect of simulated hypogravity and acceleration.
Sugahara, K; Eguchi, M
2012-03-01
We investigated the induction of protective immunity against bacterial cold-water disease (BCWD) caused by Flavobacterium psychrophilum by warmed water treatment in ayu (Plecoglossus altivelis). Fish were immersed in a live bacterial suspension (10⁷ CFU mL⁻¹) for 30 min and placed in 700 L concrete tanks. The 28 °C warmed water treatment lasted 3 days and began 1, 6, and 24 h after immersion in the live bacterial suspension. A naïve control fish group was immersed in a sterilized modified Cytophaga (MCY) broth instead of the bacterial suspension. Fourteen days after the immersion, agglutination antibody titers against F. psychrophilum were measured by using micro-titer methods. Fish were then exposed to a bacterial bath to infect them with live F. psychrophilum, and cumulative mortality was monitored. Fish treated with warmed water at 1, 6, and 24 h after immersion in the live bacterial suspension had cumulative mortalities of 36%, 30%, and 18%, respectively, all of which were significantly lower than the cumulative mortality of the naïve control fish (90%). Treated fish also showed high antibody titers against F. psychrophilum in agglutination tests. These results demonstrate that warmed water treatment could not only cure BCWD but also immunize the fish against the causative agent F. psychrophilum. Copyright © 2011 Elsevier Ltd. All rights reserved.
Executive Functions of Divers Are Selectively Impaired at 20-Meter Water Depth.
Steinberg, Fabian; Doppelmayr, Michael
2017-01-01
Moving and acting underwater within recreational or occupational activities require intact executive functions, since they subserve higher cognitive functions such as successful self-regulation, coping with novel situations, and decision making; all of which could be influenced by nitrogen narcosis due to elevated partial pressure under water. However, specific executive functions that could provide a differentiated view on humans' cognitive performance ability have not yet been systematically analyzed in full-water immersion, which is a research gap addressed within this approach to contribute to a better understanding of nitrogen narcosis. In this study, 20 young, healthy, and certified recreational divers participated and performed three different executive-function tests: the Stroop test (Inhibition), the Number/Letter test (Task switching), the 2-back test (Updating/Working memory), and a simple reaction time test (Psychomotor performance). These tests were performed once on land, at 5-meter (m) water depth, and at 20-meter (m) water depth of an indoor diving facility in standardized test conditions (26°C in all water depths). A water-proofed and fully operational tablet computer was used to present visual stimuli and to register reaction times. Performance of the simple reaction time test was not different between underwater and land testing, suggesting that reaction times were not biased by the utilization of the tablet in water immersion. Executive functions were not affected by the shallow water immersion of 5-m water depth. However, performance scores in 20-m water depth revealed a decreased performance in the incongruent test condition (i.e., an index of inhibitory control ability) of the Stroop test, while all other tests were unaffected. Even though only one out of the three tested cognitive domains was affected, the impairment of inhibitory control ability even in relatively shallow water of 20-m is a critical component that should be considered for diver's safety, since inhibition is required in self-control requiring situations where impulsive and automatic behavior must be inhibited. Our interpretation of these selective impairments is based on a discussion suggesting that different neural networks within the central nervous system, which process specific executive functions, are affected differently by nitrogen narcosis.
NASA Technical Reports Server (NTRS)
Matsnev, E. I.; Shulzhenko, Y. B.
1981-01-01
Two male volunteers were kept hypokinetic in the immersion and physiological parameters were evaluated following the experiment. Prophylactic measures (g-forces, physical exercises, and supplementary salt and water) were applied daily. Caloric and equilibrium tests were utilized to evaluate the physiological responses. The functional changes observed after the 56 day immersion were found to be of a moderate type which normalized quite quickly.
46 CFR 160.171-17 - Approval testing for adult size immersion suit.
Code of Federal Regulations, 2014 CFR
2014-10-01
... height of 4.5 m (15 ft.) above the water surface. Each subject must be able to assume a face up stable... being immersed in water at 5 °C (41 °F) for a period of one hour, each subject must be able to pick up a 9.5 mm (3/8 in.) diameter wooden pencil from a flat hard surfaced table using only one hand. Still...
46 CFR 160.171-17 - Approval testing for adult size immersion suit.
Code of Federal Regulations, 2012 CFR
2012-10-01
... height of 4.5 m (15 ft.) above the water surface. Each subject must be able to assume a face up stable... being immersed in water at 5 °C (41 °F) for a period of one hour, each subject must be able to pick up a 9.5 mm (3/8 in.) diameter wooden pencil from a flat hard surfaced table using only one hand. Still...
de Oliveira, Daniel Luiz; Smiderle, Oscar Jose; Paulino, Pollyana Priscila Schuertz; Souza, Aline das Graças
2016-12-01
Acacia is an important forest species of rapid growth whose seeds have tegument dormancy. In this work it was intended to characterize water absorption pattern after seed dormancy break, and to determine the amount of water, container size and the need of breaking the tegument dormancy, as to perform electrical conductivity test in small and large seeds of Acacia mangium (Fabaceae). The seeds were collected from 10, 8 and 6 years old trees established in poor yielding-capacity soils on savannah areas of Roraima, Brazil; seeds were classified in six lots concerning to seed size and tree age. Germination tests (50 seeds and four replications per lot) were carried out on germitest® paper maintained on gerbox at 25 °C. Imbibition was verified by seed weighing at different times (0, 2, 5, 8, 12, 16, 24, 36, 48, 60, 72, 84, 96 and 120 hours). The electrical conductivity test consisted of three experiments, distinguished by the amount of water used and by the container size in which seeds were immersed. Seeds of A. mangium coming from 10 years old trees presented increased germination percent and germination speed than seeds of six-year old trees. Small seeds presented increased in electrical conductivity and water absorption until 120 hours when compared to large seeds. The immersion of seeds of A. mangium in 40 mL of distilled water into 180 mL plastic containers, after dormancy break, it is indicated for the determination of electrical conductivity test. The ratio of electrolytes by seed mass, after 24 hours of immersion in water, turns electrical conductivity test more accurate concerning A. mangium seeds.
Erdemir, Ugur; Yildiz, Esra; Eren, Meltem Mert; Ozel, Sevda
2012-01-01
The purpose of this study was to evaluate the effect of sports and energy drinks on the surface hardness of different restorative materials over a 6-month period. Forty-two disk-shaped specimens were prepared for each of the four restorative materials tested: Compoglass F, Filtek Z250, Filtek Supreme, and Premise. Specimens were immersed for 2 min daily, up to 6 months, in six storage solutions (n=7 per material for each solution): distilled water, Powerade, Gatorade, X-IR, Burn, and Red Bull. Surface hardness was measured at baseline, after 1 week, 1 month, and 6 months. Data were analyzed statistically using repeated measures ANOVA followed by the Bonferroni test for multiple comparisons (α=0.05). Surface hardness of the restorative materials was significantly affected by both immersion solution and immersion period (p<0.001). All tested solutions induced significant reduction in surface hardness of the restorative materials over a 6-month immersion period.
Castellani, John W; O'Brien, Catherine; Tikuisis, Peter; Sils, Ingrid V; Xu, Xiaojiang
2007-12-01
Cold thermoregulatory models (CTM) have primarily been developed to predict core temperature (T(core)) responses during sedentary immersion. Few studies have examined their efficacy to predict T(core) during exercise cold exposure. The purpose of this study was to compare observed T(core) responses during exercise in cold water with the predicted T(core) from a three-cylinder (3-CTM) and a six-cylinder (6-CTM) model, adjusted to include heat production from exercise. A matrix of two metabolic rates (0.44 and 0.88 m/s walking), two water temperatures (10 and 15 degrees C), and two immersion depths (chest and waist) were used to elicit different rates of T(core) changes. Root mean square deviation (RMSD) and nonparametric Bland-Altman tests were used to test for acceptable model predictions. Using the RMSD criterion, the 3-CTM did not fit the observed data in any trial, whereas the 6-CTM fit the data (RMSD less than standard deviation) in four of eight trials. In general, the 3-CTM predicted a rapid decline in core temperature followed by a plateau. For the 6-CTM, the predicted T(core) appeared relatively tight during the early part of immersion, but was much lower during the latter portions of immersion, accounting for the nonagreement between RMSD and SD values. The 6-CTM was rerun with no adjustment for exercise metabolism, and core temperature and heat loss predictions were tighter. In summary, this study demonstrated that both thermoregulatory models designed for sedentary cold exposure, currently, cannot be extended for use during partial immersion exercise in cold water. Algorithms need to be developed to better predict heat loss during exercise in cold water.
Distortion of calculated whole-body hematocrit during lower-body immersion in water.
Knight, D R; Santoro, T; Bondi, K R
1986-11-01
We found a difference between the venous hematocrits of immersed and nonimmersed arms during immersion of the lower body in cold water but not during a comparable exposure to warm water. Fourteen healthy men were exposed to three different experimental conditions: arm immersion, body immersion, and control. The men always sat upright while both upper extremities hung vertically at their sides. During arm immersion, one forearm was completely immersed for 30 min in either cold water (28 degrees C, n = 7) or warm water (38 degrees C, n = 7). This cold-warm water protocol was repeated on separate days for exposure to the remaining conditions of body immersion (immersion of 1 forearm and all tissues below the xiphoid process) and control (no immersion). Blood samples were simultaneously drawn from cannulated veins in both antecubital fossae. Hematocrit difference (Hct diff) was measured by subtracting the nonimmersed forearm's hematocrit (Hct dry) from the immersed forearm's hematocrit (Hct wet). Hct diff was approximately zero when the men were exposed to the control condition and body immersion in warm water. In the remaining conditions, Hct wet dropped below Hct dry (P less than 0.01, 3-way analysis of variance). The decrements of Hct diff showed there were differences between venous hematocrits in immersed and nonimmersed regions of the body, indicating that changes of the whole-body hematocrit cannot be calculated from a large-vessel hematocrit soon after immersing the lower body in cold water.
Brzezinski Sinai, Isaac; Lior, Yotam; Brzezinski Sinai, Noa; Harari, Marco; Liberty, Idit F
2016-02-01
Body immersion in plain water or mineral water induces significant and unique physiological changes in most body systems. In a previous pilot study, a significant reduction in blood glucose levels among diabetes mellitus (DM) patients was found following a single immersion in Dead Sea water but not after immersion in plain water. To study the immediate and long term effects of immersion in mineral water for five consecutive days on blood glucose in patients with type 2 DM. A total of 34 patients with type 2 DM were divided into 2 groups: The first immersed in a plain water pool and the second immersed in a Dead Sea water pool; both pools were warmed to a temperature of 35°C. Immersions for 20 minutes occurred twice daily: two hours after breakfast and before dinner. Seven samples of capillary blood glucose levels were taken: fasting, before and after every immersion, prior to lunch and before bedtime. Hemoglobin A1C (HbA1c) was taken prior to the study and a re-check was conducted during the 12 weeks following the study. Blood glucose levels significantly decreased immediately after immersion both in Dead Sea water and plain water compared to their values prior to immersion (p<0.001). No significant difference was noted between both types of water. A decrease in fasting glucose levels was observed only in the group immersed in Dead Sea water when compared to plain water (6.83±5.68 mg/dl versus 4.37±1.79 respectively and the difference was close to statistical significance (p=0.071. There were no changes in HbA1c levels. Immersion for 20 minutes in water (Dead Sea or plain water) at a temperature of 35°C induced an immediate reduction in glucose levels in patients with type 2 DM.
Reduction in predicted survival times in cold water due to wind and waves.
Power, Jonathan; Simões Ré, António; Barwood, Martin; Tikuisis, Peter; Tipton, Michael
2015-07-01
Recent marine accidents have called into question the level of protection provided by immersion suits in real (harsh) life situations. Two immersion suit studies, one dry and the other with 500 mL of water underneath the suit, were conducted in cold water with 10-12 males in each to test body heat loss under three environmental conditions: calm, as mandated for immersion suit certification, and two combinations of wind plus waves to simulate conditions typically found offshore. In both studies mean skin heat loss was higher in wind and waves vs. calm; deep body temperature and oxygen consumption were not different. Mean survival time predictions exceeded 36 h for all conditions in the first study but were markedly less in the second in both calm and wind and waves. Immersion suit protection and consequential predicted survival times under realistic environmental conditions and with leakage are reduced relative to calm conditions. Copyright © 2015. Published by Elsevier Ltd.
NASA Technical Reports Server (NTRS)
Schnitzer, Emanuel
1953-01-01
A theoretical method is derived for the determination of the motions and loads during chine-immersed water landings of prismatic bodies. This method makes use of a variation of two-dimensional deflected water mass over the complete range of immersion, modified by a correction for three-dimensional flow. Equations are simplified through omission of the term proportional to the acceleration of the deflected mass for use in calculation of loads on hulls having moderate and heavy beam loading. The effects of water rise at the keel are included in these equations. In order to make a direct comparison of theory with experiment, a modification of the equations was made to include the effect of finite test-carriage mass. A simple method of computation which can be applied without reading the body of this report is presented as an appendix along with the required theoretical plots for determination of loads and motions in chine-immersed landings.
A technique for fast and accurate measurement of hand volumes using Archimedes' principle.
Hughes, S; Lau, J
2008-03-01
A new technique for measuring hand volumes using Archimedes principle is described. The technique involves the immersion of a hand in a water container placed on an electronic balance. The volume is given by the change in weight divided by the density of water. This technique was compared with the more conventional technique of immersing an object in a container with an overflow spout and collecting and weighing the volume of overflow water. The hand volume of two subjects was measured. Hand volumes were 494 +/- 6 ml and 312 +/- 7 ml for the immersion method and 476 +/- 14 ml and 302 +/- 8 ml for the overflow method for the two subjects respectively. Using plastic test objects, the mean difference between the actual and measured volume was -0.3% and 2.0% for the immersion and overflow techniques respectively. This study shows that hand volumes can be obtained more quickly than the overflow method. The technique could find an application in clinics where frequent hand volumes are required.
1966-01-01
simulating zero-gravity performance of an astronaut in a pressurized spacesuit by complete water immersion has been developed and inves- tigated. The...critical operational characteristics relating to space- craft and spacesuit design under conditions of zero gravity. In addition, the physical...the legs of the suit and are contained by insulated flight boots . The Mark IV suit used in the tests is shown in figure 1. 3 Pressure-Suit
Higgins, Trevor R; Climstein, Mike; Cameron, Melainie
2013-04-01
In team sports, a cycle of training, competition, and recovery occurs weekly during the competitive season. In this research, we evaluated hydrotherapy for recovery from a simulated game of rugby union tracked over a week of training. Twenty-four experienced male rugby union players (mean ± SD age 19.46 ± 0.82 years, weight 82.38 ± 11.12 kg, height 178.54 ± 5.75 cm) were randomly divided into 3 groups: cold water immersion (n = 8), contrast bath therapy (n = 8), and a control group (n = 8). The 2 forms of hydrotherapy were administered immediately after a simulated rugby game. Testing was conducted 1 hour before the game and at 5 intervals postgame: 1, 48, 72, 96, and 144 hours. Dependent variables included countermovement jump, 10- and 40-m sprints, sessional rating of perceived exertion (RPE), flexibility, thigh circumference, and self-reported delayed onset muscle soreness (DOMS). Significant differences in DOMS were found between the cold water immersion and contrast bath groups at 48 hours post intervention (p = 0.02), and between the control and contrast bath groups at 72 (p = 0.03) and 96 (p = 0.04) hours post intervention. Cold water immersion and contrast bath groups reported significantly different RPE at 72 hours (p = ?) and 96 hours post (p = 0.05) intervention. Athletes' perceptions of muscle soreness and sessional RPE scores for training were greater in the contrast bath group (20%) after the simulated game and throughout the training week. Although results from passive and power tests were inconclusive in determining whether cold water immersion or passive recovery was more effective in attenuating fatigue, results indicated contrast baths had little benefit in enhancing recovery during a cyclic week of rugby union.
Guzman, Marco; Laukkanen, Anne-Maria; Traser, Louisa; Geneid, Ahmed; Richter, Bernhard; Muñoz, Daniel; Echternach, Matthias
2017-10-01
This study investigated the influence of tube phonation into water on vocal fold vibration. Eight participants were analyzed via high-speed digital imaging while phonating into a silicon tube with the free end submerged into water. Two test sequences were studied: (1) phonation pre, during, and post tube submerged 5 cm into water; and (2) phonation into tube submerged 5 cm, 10 cm, and 18 cm into water. Several glottal area parameters were calculated using phonovibrograms. The results showed individual differences. However, certain trends were possible to identify based on similar results found for the majority of participants. Amplitude-to-length ratio, harmonic-to-noise ratio, and spectral flatness (derived from glottal area) decreased for all tube immersion depths, while glottal closing quotient increased for 10 cm immersion and contact quotient for 18 cm immersion. Closed quotient decreased during phonation into the tube at 5 cm depth, and jitter decreased during and after it. Results suggest that the depth of tube submersion appears to have an effect on phonation. Shallow immersion seems to promote smoother and more stable phonation, while deeper immersion may involve increased respiratory and glottal effort to compensate for the increased supraglottal resistance. This disparity, which is dependent upon the degree of flow resistance, should be considered when choosing treatment exercises for patients with various diagnoses, namely hyperfunctional or hypofunctional dysphonia.
Lipid-induced thermogenesis is up-regulated by the first cold-water immersions in juvenile penguins.
Teulier, Loïc; Rey, Benjamin; Tornos, Jérémy; Le Coadic, Marion; Monternier, Pierre-Axel; Bourguignon, Aurore; Dolmazon, Virginie; Romestaing, Caroline; Rouanet, Jean-Louis; Duchamp, Claude; Roussel, Damien
2016-07-01
The passage from shore to marine life is a critical step in the development of juvenile penguins and is characterized by a fuel selection towards lipid oxidation concomitant to an enhancement of lipid-induced thermogenesis. However, mechanisms of such thermogenic improvement at fledging remain undefined. We used two different groups of pre-fledging king penguins (Aptenodytes patagonicus) to investigate the specific contribution of cold exposure during water immersion to lipid metabolism. Terrestrial penguins that had never been immersed in cold water were compared with experimentally cold-water immersed juveniles. Experimentally immersed penguins underwent ten successive immersions at approximately 9-10 °C for 5 h over 3 weeks. We evaluated adaptive thermogenesis by measuring body temperature, metabolic rate and shivering activity in fully immersed penguins exposed to water temperatures ranging from 12 to 29 °C. Both never-immersed and experimentally immersed penguins were able to maintain their homeothermy in cold water, exhibiting similar thermogenic activity. In vivo, perfusion of lipid emulsion at thermoneutrality induced a twofold larger calorigenic response in experimentally immersed than in never-immersed birds. In vitro, the respiratory rates and the oxidative phosphorylation efficiency of isolated muscle mitochondria were not improved with cold-water immersions. The present study shows that acclimation to cold water only partially reproduced the fuel selection towards lipid oxidation that characterizes penguin acclimatization to marine life.
An investigation on mechanical properties of steel fibre reinforced for underwater welded joint
NASA Astrophysics Data System (ADS)
Navin, K.; Zakaria, M. S.; Zairi, S.
2017-09-01
Underwater pipelines are always exposed to water and have a high tendency to have corrosion especially on the welded joint. This research is about using fiber glass as steel fiber to coat the welded joint to determine the effectiveness in corrosion prevention of the welded joint. Number of coating is varied to determine the better number coating to coat the pipeline. Few samples were left without immersion in salt water and few samples are immersed into salt water with same salinity as sea water. The material sample is prepared in dog bone shape to enable to be used in Universal Tensile Machine (UTM). The material prepared is left immersed for recommended time and tested in Universal Tensile Machine. Upon analyzing the result, the result is used to determine the breakage point whether broken on the welded joint or different place and also the suitable number of coating to be used.
Acute vascular effects of carbonated warm water lower leg immersion in healthy young adults.
Ogoh, Shigehiko; Nagaoka, Ryohei; Mizuno, Takamasa; Kimura, Shohei; Shidahara, Yasuhiro; Ishii, Tomomi; Kudoh, Michinari; Iwamoto, Erika
2016-12-01
Endothelial dysfunction is associated with increased cardiovascular mortality and morbidity; however, this dysfunction may be ameliorated by several therapies. For example, it has been reported that heat-induced increases in blood flow and shear stress enhance endothelium-mediated vasodilator function. Under these backgrounds, we expect that carbon dioxide (CO 2 )-rich water-induced increase in skin blood flow improves endothelium-mediated vasodilation with less heat stress. To test our hypothesis, we measured flow-mediated dilation (FMD) before and after acute immersion of the lower legs and feet in mild warm (38°C) normal or CO 2 -rich tap water (1000 ppm) for 20 min in 12 subjects. Acute immersion of the lower legs and feet in mild warm CO 2 -rich water increased FMD (P < 0.01) despite the lack of change in this parameter upon mild warm normal water immersion. In addition, FMD was positively correlated with change in skin blood flow regardless of conditions (P < 0.01), indicating that an increase in skin blood flow improves endothelial-mediated vasodilator function. Importantly, the temperature of normal tap water must reach approximately 43°C to achieve the same skin blood flow level as that obtained during mild warm CO 2 -rich water immersion (38°C). These findings suggest that CO 2 -rich water-induced large increases in skin blood flow may improve endothelial-mediated vasodilator function while causing less heat stress. © 2016 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of The Physiological Society and the American Physiological Society.
Chandu, G S; Asnani, Pooja; Gupta, Siddarth; Faisal Khan, Mohd.
2015-01-01
Background: Use of alkaline peroxide denture cleanser with different temperature of water could cause a change in surface hardness of the acrylic denture and also has a bleaching effect. The purpose of the study was to determine the effect of increased water content during thermal cycling of hot water-treated acrylic on the surface hardness of acrylic denture base when compared to warm water treated acrylic. And to compare the bleaching effect of alkaline peroxide solution on the acrylic denture base on hot water and warm water treated acrylic. Materials and Methods: Forty samples (10 mm × 10 mm × 2.5 mm) were prepared. After the calculation of the initial hardness 40 samples, each was randomly assigned to two groups. Group A: 20 samples were immersed in 250 ml of warm distilled water at 40°C with alkaline peroxide tablet. Group B: 20 samples were immersed in 250 ml of hot distilled water at 100°C with alkaline peroxide tablet. The surface hardness of each test sample was obtained using the digital hardness testing machine recording the Rockwell hardness number before the beginning of the soaking cycles and after completion of 30 soak cycles and compared. Values were analyzed using paired t-test. Five samples from the Group A and five samples from Group B were put side by side and photographed using a Nikon D 40 digital SLR Camera and the photographs were examined visually to assess the change in color. Results: Acrylic samples immersed in hot water showed a statistically significant decrease of 5.8% in surface hardness. And those immersed in warm water showed a statistically insignificant increase of 0.67% in surface hardness. Samples from the two groups showed clinically insignificant difference in color when compared to each other on examination of the photographs. Conclusion: Thermocycling of the acrylic resin at different water bath temperature at 40°C and 100°C showed significant changes in the surface hardness. PMID:25954074
Skin oxygen tension is improved by immersion in oxygen-enriched water.
Reading, S A; Yeomans, M; Levesque, C
2013-12-01
The perceived health and physiologic functioning of skin depends on adequate oxygen availability. Economical and easily used therapeutic approaches to increase skin oxygenation could improve the subjective appearance of the skin as well as support the management of some cutaneous conditions related to chronic hypoxic ischaemia (e.g. ulcerative wounds). We have tested the hypothesis that the O2 partial pressure of skin (PskO2 ) increases during immersion in water enriched with high levels of dissolved oxygen. A commercially available device was used to produce water containing 45 to 65 mg L(-1) of dissolved O2 . Young adults (YA; n = 7), older adults (OA; n = 13) and older adults with diabetes (OAD; n = 11) completed different experiments that required them to immerse their feet in tap water (<2 mg L(-1) of O2 ; control) or O2 -enriched water (O2 -H2 O; experimental) for 30 min. Transcutaneous oximetry was used to measure PskO2 for 20 min pre- and post-immersion. Pre-immersion mean (standard deviation) PskO2 on the plantar surface of the big toe was 75 (10), 67 (10) and 65 (10) mmHg in YA, OA and OAD, respectively. Post-immersion PskO2 was 244 (25), 193 (28) and 205 (28) mmHg for the same groups. We also show that post-immersion PskO2 varies by location and with advancing age. Water is an effective vehicle for transporting dissolved O2 across the skin surface and could be used as a basis for development of economical therapeutic approaches that improve skin oxygen tension to support skin health and function. © 2013 Society of Cosmetic Scientists and the Société Française de Cosmétologie.
Physiology of Fluid and Electrolyte Responses During Inactivity: Water Immersion and Bed Rest
NASA Technical Reports Server (NTRS)
Greenleaf, John E.
1984-01-01
This manuscript emphasizes the physiology of fluid-electrolyte-hormonal responses during the prolonged inactivity of bed rest and water immersion. An understanding of the total mechanism of adaptation (deconditioning) should provide more insight into the conditioning process. Findings that need to be confirmed during bed rest and immersion are: (1) the volume and tissues of origin of fluid shifted to the thorax and head; (2) interstitial fluid pressure changes in muscle and subcutaneous tissue, particularly during immersion; and (3) the composition of the incoming presumably interstitial fluid that contributes to the early hypervolemia. Better resolution of the time course and source of the diuretic fluid is needed. Important data will be forthcoming when hypotheses are tested involving the probable action of the emerging diuretic and natriuretic hormones, between themselves and among vasopressin and aldosterone, on diuresis and blood pressure control.
An evaluation of hand immersion for rewarming individuals cooled by immersion in cold water.
Cahill, C J; Balmi, P J; Tipton, M J
1995-05-01
The hypothesis that hypothermic individuals can be actively rewarmed in the field by immersion of the extremities in hot water was investigated. Three techniques for rewarming subjects with lowered deep body temperatures were compared: a) whole body immersion to the neck in water at 40 degrees C; b) immersion of two hands plus forearms only in water at 42 degrees C; and c) passive rewarming. The suggestion that the fall in deep body temperature resulting from immersion to the neck in water at 15 degrees C could be arrested by immersing both arms in water at 42 degrees C was also investigated. Results indicated that immersion to the neck in hot water was clearly the most effective rewarming technique. No significant difference (p > 0.05) was observed in the deep body temperature response during passive rewarming or during immersion of both hands and forearms in water at 42 degrees C. In the later condition some increase in peripheral blood flow to the hands may have occurred and resulted in a heat input of approximately 12 W, but any benefit from this was negated by an associated significant decrease (p > 0.05) in intrinsic heat production. Immersing the arms in hot water during immersion to the neck in cold water appeared to accelerate rather than decelerate the rate of fall of deep body temperature. We concluded that hand rewarming, although theoretically attractive, is ineffective in practice and could be detrimental in some circumstances, by suppressing intrinsic heat production or precipitating rewarming collapse.
Effect of Children's Drinks on Color Stability of Different Dental Composites: An in vitro Study.
Habib, Ahmed Nour El-Din Ahmed; Abdelmoniem, Soad Abdelmoniem; Mahmoud, Sara Ahmed
To assess the effect of four different children's drinks on color stability of resin dental composites. A total of one hundred and twenty specimens were prepared from Grandio SO, Filtek Z350 XT and Filtek Z250 XT (forty specimens each). Specimens were thermocycled, then each group was further subdivided into four subgroups (n=10) according to the immersion media which were chocolate milk, mango juice, orange fizzy drink, and water (control). The initial color parameters of each specimen were recorded before immersion (baseline) and color change values were recorded three and seven days after immersion in each solution using a digital spectrophotometer. Atomic force microscope was used to measure the surface roughness in randomly selected samples after one week immersion in children's drinks. All the children's drinks produced color changes in the examined resin dental composites, yet there was no statistical significant difference between the effects of tested drinks on the color changes (mean ΔE) of the three different dental composites (P>0.05). All tested children's drinks caused clinically unacceptable color changes of the tested resin dental composites. Immersion in chocolate milk and orange fizzy led to the highest color changes in the tested resin dental composites.
Effect of repeated immersion solution cycles on the color stability of denture tooth acrylic resins
da SILVA, Paulo Maurício Batista; ACOSTA, Emílio José Tabaré Rodríguez; JACOBINA, Matheus; PINTO, Luciana de Rezende; PORTO, Vinícius Carvalho
2011-01-01
Objective Chemical solutions have been widely used for disinfection of dentures, but their effect on color stability of denture tooth acrylic resins after repeated procedures is still unclear. The aim of this in vitro study was to evaluate whether repeated cycles of chemical disinfectants affected the color stability of two denture tooth acrylic resins. Material and Methods Sixty disc-shaped specimens (40 mm x 3 mm) were fabricated from two different brands (Artiplus and Trilux) of denture tooth acrylic resin. The specimens from each brand (n=30) were randomly divided into 6 groups (n=5) and immersed in the following solutions: distilled water (control group) and 5 disinfecting solutions (1% sodium hypochlorite, 2% sodium hypochlorite, 5.25% sodium hypochlorite, 2% glutaraldehyde, and 4% chlorhexidine gluconate). Tooth color measurements were made by spectrophotometry. Before disinfection, the initial color of each tooth was recorded. Further color measurements were determined after subjecting the specimens to 7, 21, 30, 45, 60, and 90 immersion cycles in each tested solution. Color differences (ΔE*) were determined using the CIE L*a*b* color system. Data were analyzed using two-way repeated measures analysis of variance (ANOVA) followed by Tukey tests. The significance level was set at 5%. Results There were statistically significant differences in ΔE* among the 5 disinfectants and water during the 90 cycles of immersion for both denture tooth acrylic resins. Distilled water promoted the greatest color change in both denture tooth acrylic resins, nevertheless none of tested disinfectants promoted ΔE* values higher than 1.0 on these acrylic materials during the 90 cycles of disinfection. Conclusions Repeated immersion cycles in disinfecting solutions alter ∆E* values, however these values do not compromise the color of the tested denture tooth acrylic resins because they are imperceptible to the human eye. PMID:22230997
Al Haddad, Hani; Laursen, Paul B; Chollet, Didier; Lemaitre, Frédéric; Ahmaidi, Saïd; Buchheit, Martin
2010-08-25
This study aimed to investigate the effect of cold and thermoneutral water immersion on post-exercise parasympathetic reactivation, inferred from heart rate (HR) recovery (HRR) and HR variability (HRV) indices. Twelve men performed, on three separate occasions, an intermittent exercise bout (all-out 30-s Wingate test, 5 min seated recovery, followed by 5 min of submaximal running exercise), randomly followed by 5 min of passive (seated) recovery under either cold (CWI), thermoneutral water immersion (TWI) or control (CON) conditions. HRR indices (e.g., heart beats recovered in the first minute after exercise cessation, HRR(60)(s)) and vagal-related HRV indices (i.e., natural logarithm of the square root of the mean of the sum of the squares of differences between adjacent normal R-R intervals (Ln rMSSD)) were calculated for the three recovery conditions. HRR(60)(s) was faster in water immersion compared with CON conditions [30+/-9 beats min(-)(1) for CON vs. 43+/- 10 beats min(-)(1) for TWI (P=0.003) and 40+/-13 beats min(-)(1) for CWI (P=0.017)], while no difference was found between CWI and TWI (P=0.763). Ln rMSSD was higher in CWI (2.32+/-0.67 ms) compared with CON (1.98+/-0.74 ms, P=0.05) and TWI (2.01+/-0.61 ms, P=0.08; aES=1.07) conditions, with no difference between CON and TWI (P=0.964). Water immersion is a simple and efficient means of immediately triggering post-exercise parasympathetic activity, with colder immersion temperatures likely to be more effective at increasing parasympathetic activity. Copyright 2010 Elsevier B.V. All rights reserved.
Hypervolemia and plasma vasopressin response during water immersion in men
NASA Technical Reports Server (NTRS)
Greenleaf, J. E.; Morse, J. T.; Barnes, P. R.; Silver, J.; Keil, L. C.
1983-01-01
Immersion studies were performed on seven mildly dehydrated male subjects to examine the effect of suppression of plasma vasopressin (PVP) on diuresis in water immersion. The water was kept at close to 34.5 C and the subjects remained in the water for 4 hr after sitting for 2 hr. Na and K levels in the serum and urine were analyzed, as were osmolality, red blood cell count, renin activity, total protein, albumin amounts, hematocrit, and hemoglobin. Plasma volume was monitored from samples drawn at specified intervals during immersion. The plasma volume increased significantly 30 min after immersion, but no PVP was observed. The dehydration induced elevated serum osmotic concentrations. It is concluded that the hydration condition before immersion and the volume of fluid intake during immersion affects the hemodilution during immersion.
Effects of four recovery methods on repeated maximal rock climbing performance.
Heyman, Elsa; DE Geus, Bas; Mertens, Inge; Meeusen, Romain
2009-06-01
Considering the development of rock climbing as a competitive sport, we aimed at investigating the influence of four recovery methods on subsequent maximal climbing performance. In a randomly assigned crossover design, 13 female well-trained climbers (27.1 +/- 8.9 yr) came to the climbing center on four occasions separated by 1 wk. On each occasion, they had to perform two climbing tests (C1 and C2) until volitional exhaustion on a prepracticed route (overhanging wall, level 6b). These two tests were separated by 20 min of recovery. Four recovery methods were used in randomized order: passive recovery, active recovery (cycle ergometer, 30-40 W), electromyostimulation on the forearm muscles (bisymmetric TENS current), or cold water immersion of the forearms and arms (three periods of 5 min at 15 +/- 1 degrees C). Climbing tests' performance was reflected by the number of arm movements and climb duration. Using active recovery and cold water immersion, performance at C2 was maintained in comparison with C1, whereas C2 performance was impaired compared with C1 (P< 0.01) using electromyostimulation and passive recovery (recovery method-by-climb interaction, P < 0.05). Blood lactate decreased during recovery, with the greatest decrease occurring during active recovery (time-by-recovery method interaction, P < 0.001). Arms and forearms' skin temperatures were lower throughout the cold water immersion compared with the other three methods (P < 0.001). Active recovery and cold water immersion are two means of preserving performance when repeating acute exhausting climbing trails in female climbers. These positive effects are accompanied by a greater lactate removal and a decrease in subcutaneous tissues temperatures, respectively.
Kahanov, Leamor; Eberman, Lindsey E; Wasik, Mitchell; Alvey, Thurman
2012-01-01
To describe a case of exertional rhabdomyolysis in a collegiate American football player after preventive coldwater immersion. A healthy man (19 years old) participated in full-contact football practice followed by conditioning (2.5 hours). After practice, he entered a coach-mandated postpractice cold-water immersion and had no signs of heat illness before developing leg cramps, for which he presented to the athletic training staff. After 10 minutes of repeated stretching, massage, and replacement of electrolyte-filled fluids, he was transported to the emergency room. Laboratory tests indicated a creatine kinase (CK) level of 2545 IU/L (normal range, 45-260 IU/L), CK-myoglobin fraction of 8.5 ng/mL (normal < 6.7 ng/mL), and CK-myoglobin relative index of 30% (normal range, 25%-30%). Myoglobin was measured at 499 ng/mL (normal = 80 ng/mL). The attending physician treated the athlete with intravenous fluids. Exercise-associated muscle cramps, dehydration, exertional rhabdomyolysis. The patient was treated with rest and rehydration. One week after the incident, he began biking and swimming. Eighteen days later, the patient continued to demonstrate elevated CK levels (527 IU/L) but described no other symptoms and was allowed to return to football practice as tolerated. Two months after the incident, his CK level remained high (1900 IU/L). The athlete demonstrated no signs of heat illness upon entering the cold-water immersion but experienced severe leg cramping after immersion, resulting in a diagnosis of exertional rhabdomyolysis. Previously described cases have not linked cold-water immersion with the pathogenesis of rhabdomyolysis. In this football player, CK levels appeared to be a poor indicator of rhabdomyolysis. Our patient demonstrated no other signs of the illness weeks after the incident, yet his elevated CK levels persisted. Cold-water immersion immediately after exercise should be monitored by the athletic training staff and may not be appropriate to prevent muscle damage, given the lack of supporting evidence.
Water Plume Temperature Measurements by an Unmanned Aerial System (UAS)
DeMario, Anthony; Lopez, Pete; Plewka, Eli; Wix, Ryan; Xia, Hai; Zamora, Emily; Gessler, Dan; Yalin, Azer P.
2017-01-01
We report on the development and testing of a proof of principle water temperature measurement system deployed on an unmanned aerial system (UAS), for field measurements of thermal discharges into water. The primary elements of the system include a quad-copter UAS to which has been integrated, for the first time, both a thermal imaging infrared (IR) camera and an immersible probe that can be dipped below the water surface to obtain vertical water temperature profiles. The IR camera is used to take images of the overall water surface to geo-locate the plume, while the immersible probe provides quantitative temperature depth profiles at specific locations. The full system has been tested including the navigation of the UAS, its ability to safely carry the sensor payload, and the performance of both the IR camera and the temperature probe. Finally, the UAS sensor system was successfully deployed in a pilot field study at a coal burning power plant, and obtained images and temperature profiles of the thermal effluent. PMID:28178215
Water Plume Temperature Measurements by an Unmanned Aerial System (UAS).
DeMario, Anthony; Lopez, Pete; Plewka, Eli; Wix, Ryan; Xia, Hai; Zamora, Emily; Gessler, Dan; Yalin, Azer P
2017-02-07
We report on the development and testing of a proof of principle water temperature measurement system deployed on an unmanned aerial system (UAS), for field measurements of thermal discharges into water. The primary elements of the system include a quad-copter UAS to which has been integrated, for the first time, both a thermal imaging infrared (IR) camera and an immersible probe that can be dipped below the water surface to obtain vertical water temperature profiles. The IR camera is used to take images of the overall water surface to geo-locate the plume, while the immersible probe provides quantitative temperature depth profiles at specific locations. The full system has been tested including the navigation of the UAS, its ability to safely carry the sensor payload, and the performance of both the IR camera and the temperature probe. Finally, the UAS sensor system was successfully deployed in a pilot field study at a coal burning power plant, and obtained images and temperature profiles of the thermal effluent.
Barwood, Martin J; Corbett, Jo; Tipton, Mike; Wagstaff, Christopher; Massey, Heather
2017-05-15
Accidental cold-water immersion (CWI) triggers the life-threatening cold shock response (CSR) which is a precursor to sudden death on immersion. One practical means of reducing the CSR is to induce an habituation by undergoing repeated short CWIs. Habituation of the CSR is known to be partially reversed by the concomitant experience of acute anxiety, raising the possibility that repeated anxiety could prevent CSR habituation; we tested this hypothesis. Sixteen participants (12 male, 4 female) completed seven, seven-minute immersions in to cold water (15°C). Immersion one acted as a control (CON1). During immersions two to five, which would ordinarily induce an habituation, anxiety levels were repeatedly increased (CWI-ANX rep ) by deception and a demanding mathematical task. Immersions six and seven were counter-balanced with another high anxiety condition (CWI-ANX rep ) or a further control (CON2). Anxiety (20cm visual analogue scale) and cardiorespiratory responses (cardiac frequency [f c ], respiratory frequency [f R ], tidal volume [V T ], minute ventilation [V̇ E ]) were measured. Comparisons were made between experimental immersions (CON1, final CWI-ANX rep , CON2), across habituation immersions and with data from a previous study. Anxiety levels were sustained at a similar level throughout the experimental and habituation immersions (mean [SD] CON1: 7.0 [4.0] cm; CON2: 5.8 [5.2] cm cf CWI-ANX rep : 7.3 [5.5] cm; p>0.05). This culminated in failure of the CSR to habituate even when anxiety levels were not manipulated (i.e. CON2). These data were different (p<0.05) to previous studies where anxiety levels were allowed to fall across habituation immersions and the CSR consequently habituated. Repeated anxiety prevented CSR habituation. A protective strategy that includes inducing habituation for those at risk should include techniques to lower anxiety associated with the immersion event or habituation may not be beneficial in the emergency scenario. Copyright © 2017 Elsevier Inc. All rights reserved.
Haghgou, Hamid R; Haghgoo, Roza; Asdollah, Fatemah Molla
2016-01-01
The consumption of carbonated beverages is one of the etiological factors that cause dental erosion. The purpose of this research was to compare changes in the microhardness of permanent and primary teeth after immersion in two types of carbonated beverages. This investigation was done on 30 healthy permanent molars and 30 healthy primary canines. Each group of primary and permanent teeth was subdivided into three groups of 10 teeth. The teeth was immersed in 40 ml of each of the three beverages for 5 min. One subgroup was immersed in water (as a control). The next was immersed in Lemon Delster and the last subgroup was immersed in Coca-Cola. The microhardness of enamel was measured using the Vickers method before and after immersion. Finally, the data was analyzed by paired t-test, one-way analysis of variance, and t-test. Microhardness reduction in the primary teeth was significant in both the Lemon Delster and Coca-Cola groups (P < 0.05). This reduction was also statistically significant in the permanent teeth (P < 0.05). A comparison of the enamel changes in the primary teeth with permanent teeth after immersion in both beverages showed a greater microhardness reduction in the primary teeth in both the experimental groups. Coca-Cola and Lemon Delster caused a significant reduction of microhardness in tooth enamel. This reduction was greater in primary teeth than in permanent teeth, and was also greater after immersion in Coca-Cola than after immersion in Lemon Delster.
Whole body cooling by immersion in water at moderate temperatures.
Marino, F; Booth, J
1998-06-01
This study investigated the potential use of whole body cooling by water immersion for lowering body temperatures prior to endurance exercise. Rectal temperature (Tre), mean skin temperature (Tsk), oxygen consumption (VO2), and ventilation (VE) were measured in 7 male and 3 female subjects who were immersed in a water bath for up to 60 min. Initial water temperature was 28.8+/-1.5 degrees C and decreased to 23.8+/-1.1 degrees C by the end of immersion. Pre-immersion Tre of 37.34+/-0.36 degrees C was not altered by 60 min water immersion but decreased to 36.64+/-0.34 degrees C at 3 min post immersion (p < 0.01). Tsk decreased from 33.23+/-1.4 degrees C to 26.95+/-1.8 degrees C (p < 0.01) at the end of immersion. Reductions in Tre and Tsk resulted in reduced body heat content (Hc) of approximately 545 kJ (p < 0.01) at the end of immersion. VO2 and VE increased from pre-immersion values of 0.34+/-0.08 L x min(-1) and 6.2+/-1.4 L x min(-1) to 0.54+/-0.09 L x min(-) and 11.5+/-5.4 L x min(-1) at the end of immersion, respectively. Heart rate remained unchanged throughout immersion. These results indicate that whole body immersion in moderately cold water temperatures is an effective cooling maneuver for lowering body temperatures and body Hc in the absence of severe physiological responses generally associated with sudden cold stress.
Caldwell, Joanne N; van den Heuvel, Anne M J; Kerry, Pete; Clark, Mitchell J; Peoples, Gregory E; Taylor, Nigel A S
2018-04-01
What is the central question of this study? Does the cold-water immersion (14°C) of profoundly hyperthermic individuals induce reductions in cutaneous and limb blood flow of sufficient magnitude to impair heat loss relative to the size of the thermal gradient? What is the main finding and its importance? The temperate-water cooling (26°C) of profoundly hyperthermic individuals was found to be rapid and reproducible. A vascular mechanism accounted for that outcome, with temperature-dependent differences in cutaneous and limb blood flows observed during cooling. Decisions relating to cooling strategies must be based upon deep-body temperature measurements that have response dynamics consistent with the urgency for cooling. Physiologically trivial time differences for cooling the intrathoracic viscera of hyperthermic individuals have been reported between cold- and temperate-water immersion treatments. One explanation for that observation is reduced convective heat delivery to the skin during cold immersion, and this study was designed to test both the validity of that observation, and its underlying hypothesis. Eight healthy men participated in four head-out water immersions: two when normothermic, and two after exercise-induced, moderate-to-profound hyperthermia. Two water temperatures were used within each thermal state: temperate (26°C) and cold (14°C). Tissue temperatures were measured at three deep-body sites (oesophagus, auditory canal and rectum) and eight skin surfaces, with cutaneous vascular responses simultaneously evaluated from both forearms (laser-Doppler flowmetry and venous-occlusion plethysmography). During the cold immersion of normothermic individuals, oesophageal temperature decreased relative to baseline (-0.31°C over 20 min; P < 0.05), whilst rectal temperature increased (0.20°C; P < 0.05). When rendered hyperthermic, oesophageal (-0.75°C) and rectal temperatures decreased (-0.05°C) during the transition period (<8.5 min, mostly in air at 22°C), with the former dropping to 37.5°C only 54 s faster when immersed in cold rather than in temperate water (P < 0.05). Minimal cutaneous vasoconstriction occurred during either normothermic immersion, whereas pronounced constriction was evident during both immersions when subjects were hyperthermic, with the colder water eliciting a greater vascular response (P < 0.05). It was concluded that the rapid intrathoracic cooling of asymptomatic, hyperthermic individuals in temperate water was a reproducible phenomenon, with slower than expected cooling in cold water brought about by stronger cutaneous vasoconstriction that reduced convective heat delivery to the periphery. © 2018 The Authors. Experimental Physiology © 2018 The Physiological Society.
Temperature-induced changes in neuromuscular function: central and peripheral mechanisms.
Goodman, D; Hancock, P A; Runnings, D W; Brown, S L
1984-10-01
Three series of experimental tests were conducted on subjects under both elevated and depressed thermal conditions. Tripartite series consisted of whole-body immersion excepting the head, whole-body immersion excepting the head and response limb, and immersion of the discrete-response limb. Measures of physiological and behavioural responses were made at sequential .4 degrees C changes during whole-body immersions and approximately 5 degrees C changes of water temperature during the immersion of a limb only. Results suggested that velocity of nerve conduction decreased with thermal depression. Premotor, motor, simple, and choice reaction times varied differentially as a function of the hot and cold conditions. Implications of these differential effects on neuromuscular function are examined with respect to person-machine performance in artificially induced or naturally occurring extremes of ambient temperature.
Effect of cold-water immersion on skeletal muscle contractile properties in soccer players.
García-Manso, Juan Manuel; Rodríguez-Matoso, Darío; Rodríguez-Ruiz, David; Sarmiento, Samuel; de Saa, Yves; Calderón, Javier
2011-05-01
This study was designed to analyze changes in muscle response after cold-water immersion. The vastus lateralis of the dominant leg was analyzed in 12 professional soccer players from the Spanish 2nd Division B using tensiomyography, before and after four cold-water immersions at 4°C lasting 4 mins each. Core temperature, skin temperature, and heart rate were monitored. A significant interaction (P ≤ 0.05) was found in muscle deformation between control conditions (5.12 ± 2.27 mm) and (1) immersion 3 (3.64 ± 2.27 mm) and (2) immersion 4 (3.38 ± 1.34 mm). A steady decrease was also observed in response velocity (immersion 1, -7.3%; immersion 2, -25.9%; immersion 3, -30.0%; immersion 4, -36.6%) and contraction velocity (immersion 1, -11.5%; immersion 2, -22.1%; immersion 3, -35.0%; immersion 4, -41.9%), with statistically significant differences (P ≤ 0.05) in relation to the reference values commencing with the third immersion. No significant differences were found between control conditions in subsequent exposures to cold water for the values of response time and contraction time. Sustained time and reaction time showed an increase during repeated exposures and with longer exposure time, although the increase was not statistically significant. This study shows that repeated cold-water immersions (4 × 4 mins at 4°C) cause considerable alterations to muscle behavior. These alterations significantly affect the state of muscles and their response capacity, particularly in relation to muscle stiffness and muscle contraction velocity.
Lee, Elaine C; Watson, Greig; Casa, Douglas; Armstrong, Lawrence E; Kraemer, William; Vingren, Jakob L; Spiering, Barry A; Maresh, Carl M
2012-01-01
Cold-water immersion is the criterion standard for treatment of exertional heat illness. Cryotherapy and water immersion also have been explored as ergogenic or recovery aids. The kinetics of inflammatory markers, such as interleukin-6 (IL-6), during cold-water immersion have not been characterized. To characterize serum IL-6 responses to water immersion at 2 temperatures and, therefore, to initiate further research into the multidimensional benefits of immersion and the evidence-based selection of specific, optimal immersion conditions by athletic trainers. Controlled laboratory study. Human performance laboratory Patients or Other Participants: Eight college-aged men (age = 22 ± 3 years, height = 1.76 ± 0.08 m, mass = 77.14 ± 9.77 kg, body fat = 10% ± 3%, and maximal oxygen consumption = 50.48 ± 4.75 mL·kg(-1) min(-1)). Participants were assigned randomly to receive either cold (11.70°C ± 2.02°C, n = 4) or warm (23.50°C ± 1.00°C, n = 4) water-bath conditions after exercise in the heat (temperature = 37°C, relative humidity = 52%) for 90 minutes or until volitional cessation. Whole-body cooling rates were greater in the cold water-bath condition for the first 6 minutes of water immersion, but during the 90-minute, postexercise recovery, participants in the warm and cold water-bath conditions experienced similar overall whole-body cooling. Heart rate responses were similar for both groups. Participants in the cold water-bath condition experienced an overall slight increase (30.54% ± 77.37%) in IL-6 concentration, and participants in the warm water-bath condition experienced an overall decrease (-69.76% ± 15.23%). We have provided seed evidence that cold-water immersion is related to subtle IL-6 increases from postexercise values and that warmer water-bath temperatures might dampen this increase. Further research will elucidate any anti-inflammatory benefit associated with water-immersion treatment and possible multidimensional uses of cooling therapies.
NASA Astrophysics Data System (ADS)
Hugues, Jonathan; Andrieu, Eric; Blanc, Christine; Cloué, Jean-Marc
The electrochemical behavior of alloy 718 in a chloride-containing boric acid solution was studied to determine the influence of chloride ions as contaminants of pool water of nuclear power plants on the corrosion behavior of the alloy. Experiments were performed at 20°C and 60°C with chloride concentrations from 1.5 to 15 000 ppm, using stationary measurements i.e. OCP versus time measurements and plotting of current-potential curves. After the electrochemical tests, the samples were observed using optical microscopy. Immersion tests in chloride-containing boric acid solutions were also carried out: samples were immersed for a time as long as 17 weeks at open circuit potential and their residual mechanical properties were measured. Results showed that, whatever the chloride concentration, there was no corrosion for samples immersed at open circuit potential. However, when the samples were polarized at high potentials, intergranular corrosion might be observed in occluded zones.
Water immersion in preeclampsia.
Elvan-Taşpinar, Ayten; Franx, Arie; Delprat, Constance C; Bruinse, Hein W; Koomans, Hein A
2006-12-01
Preeclampsia is associated with profound vasoconstriction in most organ systems and reduced plasma volume. Because water immersion produces a marked central redistribution of blood volume and suppresses the renin-angiotensin system response and sympathetic activity, we hypothesized that water immersion might be useful in the treatment of preeclampsia. The effects of thermoneutral water immersion for 3 hours on central and peripheral hemodynamics were evaluated in 7 preeclamptic patients, 7 normal pregnant control patients, and 7 nonpregnant women. Finger plethysmography was used to determine hemodynamic measurements (cardiac output and total peripheral resistance), and forearm blood flow was measured by strain gauge plethysmography. Postischemic hyperemia was used to determine endothelium-dependent vasodilation. Analysis was by analysis of variance for repeated measurements. During water immersion cardiac output increased while diastolic blood pressure and heart rate decreased, although systolic blood pressure remained unchanged in each group. Forearm blood flow increased significantly in the normal pregnant and preeclamptic subjects. Total peripheral resistance decreased in all groups, but values in preeclamptic patients remained above those of normotensive pregnant women. Water immersion had no effect on endothelium-dependent vasodilation in the preeclamptic group, and most hemodynamic changes that were observed reversed to baseline within 2 hours of completion of the procedure. Although water immersion results in hemodynamic alterations in a manner that is theoretically therapeutic for women with preeclampsia, the effect was limited and short-lived. In addition water immersion had no effect on endothelium-dependent vasodilation in women with preeclampsia. The therapeutic potential for water immersion in preeclampsia appears to be limited.
Kahanov, Leamor; Eberman, Lindsey E.; Wasik, Mitchell; Alvey, Thurman
2012-01-01
Objective: To describe a case of exertional rhabdomyolysis in a collegiate American football player after preventive cold-water immersion. Background: A healthy man (19 years old) participated in full-contact football practice followed by conditioning (2.5 hours). After practice, he entered a coach-mandated post-practice cold-water immersion and had no signs of heat illness before developing leg cramps, for which he presented to the athletic training staff. After 10 minutes of repeated stretching, massage, and replacement of electrolyte-filled fluids, he was transported to the emergency room. Laboratory tests indicated a creatine kinase (CK) level of 2545 IU/L (normal range, 45–260 IU/L), CK-myoglobin fraction of 8.5 ng/mL (normal < 6.7 ng/mL), and CK-myoglobin relative index of 30% (normal range, 25%– 30%). Myoglobin was measured at 499 ng/mL (normal = 80 ng/mL). The attending physician treated the athlete with intravenous fluids. Differential Diagnosis: Exercise-associated muscle cramps, dehydration, exertional rhabdomyolysis. Treatment: The patient was treated with rest and rehydration. One week after the incident, he began biking and swimming. Eighteen days later, the patient continued to demonstrate elevated CK levels (527 IU/L) but described no other symptoms and was allowed to return to football practice as tolerated. Two months after the incident, his CK level remained high (1900 IU/L). Uniqueness: The athlete demonstrated no signs of heat illness upon entering the cold-water immersion but experienced severe leg cramping after immersion, resulting in a diagnosis of exertional rhabdomyolysis. Previously described cases have not linked cold-water immersion with the pathogenesis of rhabdomyolysis. Conclusions: In this football player, CK levels appeared to be a poor indicator of rhabdomyolysis. Our patient demonstrated no other signs of the illness weeks after the incident, yet his elevated CK levels persisted. Cold-water immersion immediately after exercise should be monitored by the athletic training staff and may not be appropriate to prevent muscle damage, given the lack of supporting evidence. PMID:22488291
NASA Technical Reports Server (NTRS)
Greenleaf, J. E.; Simanonok, K.; Bernauer, E. M.; Wade, C. E.; Keil, L. C.
1992-01-01
The purpose of this research was to test the hypotesis that a reduction in blood volume would attenuate or eliminate immersion-induced increases in cardiac output (Q(sub co)) and urine excretion, and to investigate accompanying vasoactive and fluid-electrolyte hormonal responses. Eight men (19-23 yr) were supine during a 2-hr control period in air, and then sat for 5-hr test periods in air at 20 C (dry control, DC); water at 34.5 C (wet control, WC); and water (34.5 C) after hemorrhage (WH) of 14.8 plus or minus 0.3 percent of their blood volume. Blood volume was -11.6 plus or minus 0.6 percent at immersion (time 0). Mean (bar-X hrs 1-5) Q(sub co) was unchanged in WC (5.3 plus or minus 0.01 l/min) and in WH (4.5 plus or minus 0.1 l/min), but decreased (P less than 0.05) in DC to 3.6 plus or minus 0.1 l/min. Mean urine excretion rates were 1.0 plus or minus 0.2 ml/min for DC and 1.1 plus or minus 0.2 ml/min for WH; both were lower (P less than 0.05) than that for WC of 2.0 plus or minus 0.4 ml/min. Plasma (Na+) and (Osm) were unchanged in all experiments. Mean plasma vasopressin (PVP) (bar-X hrs 1-5) was 1.1 plus or minus 0.1 pg/ml in WC, and higher (P less than 0.05) in DC (2.1 plus or minus 0.2 pg/ml)and WH (2.1 plus or minus 0.1 pg/ml); it was unchanged during air and water test periods. Thus, hemorrhage attenuated the immersion-induced increase in Q(sub co), eliminated the WC diuresis, maintained plasma renin activity and PVP at DC levels and did not change immersion-induced aldosterone suppression; the osmotic diuresis during control immersion is apparently not due to either aldosterone suppression or vasopressin suppression.
Screening of lipid composition for scalable fabrication of solvent free lipid microarrays
NASA Astrophysics Data System (ADS)
Ghazanfari, Lida; Lenhert, Steven
2016-12-01
Liquid microdroplet arrays on surfaces are a promising approach to the miniaturization of laboratory processes such as high throughput screening. The fluid nature of these droplets poses unique challenges and opportunities in their fabrication and application, particularly for the scalable integration of multiple materials over large areas and immersion into cell culture solution. Here we use pin spotting and nanointaglio printing to screen a library of lipids and their mixtures for their compatibility with these fabrication processes, as well as stability upon immersion into aqueous solution. More than 200 combinations of natural and synthetic oils composed of fatty acids, triglycerides, and hydrocarbons were tested for their pin-spotting and nanointaglio print quality and their ability to contain the fluorescent compound TRITC upon immersion in water. A combination of castor oil and hexanoic acid at the ratio of 1:1 (w/w) was found optimal for producing reproducible patterns that are stable upon immersion into water. This method is capable of large scale nano-materials integration.
Arterial and intraocular pressure changes after a single-session hot-water immersion.
Findikoglu, Gulin; Cetin, Ebru Nevin; Sarsan, Ayse; Senol, Hande; Yildirim, Cem; Ardic, Fusun
2015-01-01
The aim of this study is to investigate the effect of head-out hot-water immersion on the intraocular pressure (IOP) of healthy subjects and investigate whether this intervention alters cardiovascular and microcirculatory responses. METHODs: 16 male and 18 female healthy young adults were immersed in 39 degrees C water up to shoulder level for 20 minutes. Blood pressure (BP), heart rate (HR) and IOP were measured pre-immersion, post-immersion and five minutes after immersion on the same day. Tono-Pen was used to measure IOP. Mean arterial blood pressure (MAP), systolic pressure rate product (S-PRP), diastolic pressure rate product (D-PRP), pulse pressure (PP), mean ocular perfusion pressure (mean-OPP), systolic ocular perfusion pressure (S-OPP) and diastolic ocular perfusion pressure (D-OPP) were calculated. Systolic BP (SBP), diastolic BP (DBP), MAP, IOP, S-OPP, D-OPP and mean-OPP decreased; HR increased five minutes after immersion in the pool and post-immersion out of the pool significantly, compared to pre-immersion data (p < 0.05). HR, S-PRP and D-PRP measured five minutes after immersion were significantly higher from post-immersion (p < 0.05). PP and S-OPP were significantly different five minutes after immersion compared to pre-immersion. There was no statistically significant correlation between IOP and SBP, DBP, MAP, S-PRP, D-PRP, PP, S-OPP, D-OPP, or mean-OPP (p > 0.05). Physiological hemodynamic response to single head-out hot-water immersion caused a statistically significant decrease in IOP. Preliminary results could help to clarify vascular reactions and IOP changes during hot-water immersion that might be potentially therapeutic in glaucoma patients.
The adhesive strength and initial viscosity of denture adhesives.
Han, Jian-Min; Hong, Guang; Dilinuer, Maimaitishawuti; Lin, Hong; Zheng, Gang; Wang, Xin-Zhi; Sasaki, Keiichi
2014-11-01
To examine the initial viscosity and adhesive strength of modern denture adhesives in vitro. Three cream-type denture adhesives (Poligrip S, Corect Cream, Liodent Cream; PGS, CRC, LDC) and three powder-type denture adhesives (Poligrip Powder, New Faston, Zanfton; PGP, FSN, ZFN) were used in this study. The initial viscosity was measured using a controlled-stress rheometer. The adhesive strength was measured according to ISO-10873 recommended procedures. All data were analyzed independently by one-way analysis of variance combined with a Student-Newman-Keuls multiple comparison test at a 5% level of significance. The initial viscosity of all the cream-type denture adhesives was lower than the powder-type adhesives. Before immersion in water, all the powder-type adhesives exhibited higher adhesive strength than the cream-type adhesives. However, the adhesive strength of cream-type denture adhesives increased significantly and exceeded the powder-type denture adhesives after immersion in water. For powder-type adhesives, the adhesive strength significantly decreased after immersion in water for 60 min, while the adhesive strength of the cream-type adhesives significantly decreased after immersion in water for 180 min. Cream-type denture adhesives have lower initial viscosity and higher adhesive strength than powder type adhesives, which may offer better manipulation properties and greater efficacy during application.
Cronin, N.J.; Valtonen, A.M.; Waller, B.; Pöyhönen, T.; Avela, J.
2016-01-01
Background: Reflex excitability is increased in hemiplegic patients compared to healthy controls. One challenge of stroke rehabilitation is to decrease the effects of hyperreflexia, which may be possible with water immersion. Methods/Aims: The present study examined the effects of acute water immersion on electrically-evoked Hmax:Mmax ratios (a measure of reflex excitability) in 7 hyperreflexive hemiplegic patients and 7 age-matched healthy people. Hmax:Mmax ratios were measured from soleus on dry land (L1), immediately after (W1) and 5 minutes after immersion (W5), and again after five minutes on land (L5). Results: Water immersion led to an acute increase in Hmax:Mmax ratio in both groups. However, after returning to dry land, there was a non-significant decrease in the Hmax:Mmax ratio of 8% in the hemiplegic group and 10% in healthy controls compared to pre-immersion values. Interpretation: A short period of water immersion can decrease peripheral reflex excitability after returning to dry land in both healthy controls and post-stroke patients, although longer immersion periods may be required for sustainable effects. Water immersion may offer promise as a low-risk, non-invasive and non-pharmaceutical method of decreasing hyperreflexivity, and could thus support aquatic rehabilitation following stroke. PMID:26944824
Cronin, N J; Valtonen, A M; Waller, B; Pöyhönen, T; Avela, J
2016-03-01
Reflex excitability is increased in hemiplegic patients compared to healthy controls. One challenge of stroke rehabilitation is to decrease the effects of hyperreflexia, which may be possible with water immersion. Methods/Aims: The present study examined the effects of acute water immersion on electrically-evoked Hmax:Mmax ratios (a measure of reflex excitability) in 7 hyperreflexive hemiplegic patients and 7 age-matched healthy people. Hmax:Mmax ratios were measured from soleus on dry land (L1), immediately after (W1) and 5 minutes after immersion (W5), and again after five minutes on land (L5). Water immersion led to an acute increase in Hmax:Mmax ratio in both groups. However, after returning to dry land, there was a non-significant decrease in the Hmax:Mmax ratio of 8% in the hemiplegic group and 10% in healthy controls compared to pre-immersion values. A short period of water immersion can decrease peripheral reflex excitability after returning to dry land in both healthy controls and post-stroke patients, although longer immersion periods may be required for sustainable effects. Water immersion may offer promise as a low-risk, non-invasive and non-pharmaceutical method of decreasing hyperreflexivity, and could thus support aquatic rehabilitation following stroke.
Manzanilla-Granados, Héctor M; Saint-Martín, Humberto; Fuentes-Azcatl, Raúl; Alejandre, José
2015-07-02
The solubility of NaCl, an equilibrium between a saturated solution of ions and a solid with a crystalline structure, was obtained from molecular dynamics simulations using the SPC/E and TIP4P-Ew water models. Four initial setups on supersaturated systems were tested on sodium chloride (NaCl) solutions to determine the equilibrium conditions and computational performance: (1) an ionic solution confined between two crystal plates of periodic NaCl, (2) a solution with all the ions initially distributed randomly, (3) a nanocrystal immersed in pure water, and (4) a nanocrystal immersed in an ionic solution. In some cases, the equilibration of the system can take several microseconds. The results from this work showed that the solubility of NaCl was the same, within simulation error, for the four setups, and in agreement with previously reported values from simulations with the setup (1). The system of a nanocrystal immersed in supersaturated solution was found to equilibrate faster than others. In agreement with laser-Doppler droplet measurements, at equilibrium with the solution the crystals in all the setups had a slight positive charge.
Optical and color stabilities of paint-on resins for shade modification of restorative resins.
Arikawa, Hiroyuki; Kanie, Takahito; Fujii, Koichi; Ban, Seiji; Homma, Tetsuya; Takahashi, Hideo
2004-06-01
The purpose of this study was to examine the optical and color stabilities of the paint-on resin used for shade modification of restorative resins. Three shades of paint-on resin and two crown and bridge resins were used. The light transmittance characteristics of the materials during accelerated aging tests such as water immersion, toothbrush abrasion, ultraviolet (UV) light irradiation, and staining tests were measured. Discolorations of materials resulting from tests were also determined. There were no significant effects of water immersion, toothbrush abrasion and UV light irradiation on the light transmittance and visible color change of paint-on resins, whereas the staining tests significantly decreased the light transmittance and increased color change of the translucent shades of materials. Our results indicate that the paint-on resins exhibit stable optical properties and color appearance, which are at least as good as the crown and bridge resins.
Cold-water immersion (cryotherapy) for preventing and treating muscle soreness after exercise.
Bleakley, Chris; McDonough, Suzanne; Gardner, Evie; Baxter, G David; Hopkins, J Ty; Davison, Gareth W
2012-02-15
Many strategies are in use with the intention of preventing or minimising delayed onset muscle soreness and fatigue after exercise. Cold-water immersion, in water temperatures of less than 15°C, is currently one of the most popular interventional strategies used after exercise. To determine the effects of cold-water immersion in the management of muscle soreness after exercise. In February 2010, we searched the Cochrane Bone, Joint and Muscle Trauma Group Specialised Register, the Cochrane Central Register of Controlled Trials (The Cochrane Library (2010, Issue 1), MEDLINE, EMBASE, Cumulative Index to Nursing and Allied Health (CINAHL), British Nursing Index and archive (BNI), and the Physiotherapy Evidence Database (PEDro). We also searched the reference lists of articles, handsearched journals and conference proceedings and contacted experts.In November 2011, we updated the searches of CENTRAL (2011, Issue 4), MEDLINE (up to November Week 3 2011), EMBASE (to 2011 Week 46) and CINAHL (to 28 November 2011) to check for more recent publications. Randomised and quasi-randomised trials comparing the effect of using cold-water immersion after exercise with: passive intervention (rest/no intervention), contrast immersion, warm-water immersion, active recovery, compression, or a different duration/dosage of cold-water immersion. Primary outcomes were pain (muscle soreness) or tenderness (pain on palpation), and subjective recovery (return to previous activities without signs or symptoms). Three authors independently evaluated study quality and extracted data. Some of the data were obtained following author correspondence or extracted from graphs in the trial reports. Where possible, data were pooled using the fixed-effect model. Seventeen small trials were included, involving a total of 366 participants. Study quality was low. The temperature, duration and frequency of cold-water immersion varied between the different trials as did the exercises and settings. The majority of studies failed to report active surveillance of pre-defined adverse events.Fourteen studies compared cold-water immersion with passive intervention. Pooled results for muscle soreness showed statistically significant effects in favour of cold-water immersion after exercise at 24 hour (standardised mean difference (SMD) -0.55, 95% CI -0.84 to -0.27; 10 trials), 48 hour (SMD -0.66, 95% CI -0.97 to -0.35; 8 trials), 72 hour (SMD -0.93; 95% CI -1.36 to -0.51; 4 trials) and 96 hour (SMD -0.58; 95% CI -1.00 to -0.16; 5 trials) follow-ups. These results were heterogeneous. Exploratory subgroup analyses showed that studies using cross-over designs or running based exercises showed significantly larger effects in favour of cold-water immersion. Pooled results from two studies found cold-water immersion groups had significantly lower ratings of fatigue (MD -1.70; 95% CI -2.49 to -0.90; 10 units scale, best to worst), and potentially improved ratings of physical recovery (MD 0.97; 95% CI -0.10 to 2.05; 10 units scale, worst to best) immediately after the end of cold-water immersion.Five studies compared cold-water with contrast immersion. Pooled data for pain showed no evidence of differences between the two groups at four follow-up times (immediately, 24, 48 and 72 hours after treatment). Similar findings for pooled analyses at 24, 48 and 72 hour follow-ups applied to the four studies comparing cold-water with warm-water immersion. Single trials only compared cold-water immersion with respectively active recovery, compression and a second dose of cold-water immersion at 24 hours. There was some evidence that cold-water immersion reduces delayed onset muscle soreness after exercise compared with passive interventions involving rest or no intervention. There was insufficient evidence to conclude on other outcomes or for other comparisons. The majority of trials did not undertake active surveillance of pre-defined adverse events. High quality, well reported research in this area is required.
Haghgou, Hamid R.; Haghgoo, Roza; Asdollah, Fatemah Molla
2016-01-01
Objectives: The consumption of carbonated beverages is one of the etiological factors that cause dental erosion. The purpose of this research was to compare changes in the microhardness of permanent and primary teeth after immersion in two types of carbonated beverages. Materials and Methods: This investigation was done on 30 healthy permanent molars and 30 healthy primary canines. Each group of primary and permanent teeth was subdivided into three groups of 10 teeth. The teeth was immersed in 40 ml of each of the three beverages for 5 min. One subgroup was immersed in water (as a control). The next was immersed in Lemon Delster and the last subgroup was immersed in Coca-Cola. The microhardness of enamel was measured using the Vickers method before and after immersion. Finally, the data was analyzed by paired t-test, one-way analysis of variance, and t-test. Results: Microhardness reduction in the primary teeth was significant in both the Lemon Delster and Coca-Cola groups (P < 0.05). This reduction was also statistically significant in the permanent teeth (P < 0.05). A comparison of the enamel changes in the primary teeth with permanent teeth after immersion in both beverages showed a greater microhardness reduction in the primary teeth in both the experimental groups. Conclusions: Coca-Cola and Lemon Delster caused a significant reduction of microhardness in tooth enamel. This reduction was greater in primary teeth than in permanent teeth, and was also greater after immersion in Coca-Cola than after immersion in Lemon Delster. PMID:27583223
NASA Astrophysics Data System (ADS)
Yang, Se-fei; Wen, Ying; Yi, Pan; Xiao, Kui; Dong, Chao-fang
2017-11-01
The effects of chitosan inhibitor on the corrosion behavior of 2205 duplex stainless steel were studied by electrochemical measurements, immersion tests, and stereology microscopy. The influences of immersion time, temperature, and chitosan concentration on the corrosion inhibition performance of chitosan were investigated. The optimum parameters of water-soluble chitosan on the corrosion inhibition performance of 2205 duplex stainless steel were also determined. The water-soluble chitosan showed excellent corrosion inhibition performance on the 2205 duplex stainless steel. Polarization curves demonstrated that chitosan acted as a mixed-type inhibitor. When the stainless steel specimen was immersed in the 0.2 g/L chitosan solution for 4 h, a dense and uniform adsorption film covered the sample surface and the inhibition efficiency (IE) reached its maximum value. Moreover, temperature was found to strongly influence the corrosion inhibition of chitosan; the inhibition efficiency gradually decreased with increasing temperature. The 2205 duplex stainless steel specimen immersed in 0.4 g/L water-soluble chitosan at 30°C displayed the best corrosion inhibition among the investigated specimens. Moreover, chitosan decreased the corrosion rate of the 2205 duplex stainless steel in an FeCl3 solution.
Human thermal responses during leg-only exercise in cold water.
Golden, F S; Tipton, M J
1987-10-01
1. Exercise during immersion in cold water has been reported by several authors to accelerate the rate of fall of core temperature when compared with rates seen during static immersion. The nature of the exercise performed, however, has always been whole-body in nature. 2. In the present investigation fifteen subjects performed leg exercise throughout a 40 min head-out immersion in water at 15 degrees C. The responses obtained were compared with those seen when the subjects performed an identical static immersion. 3. Aural and rectal temperatures were found to fall by greater amounts during static immersion. 4. It is concluded that 'the type of exercise performed' should be included in the list of factors which affect core temperature during cold water immersion.
Lee, Elaine C.; Watson, Greig; Casa, Douglas; Armstrong, Lawrence E.; Kraemer, William; Vingren, Jakob L.; Spiering, Barry A.; Maresh, Carl M.
2012-01-01
Context Cold-water immersion is the criterion standard for treatment of exertional heat illness. Cryotherapy and water immersion also have been explored as ergogenic or recovery aids. The kinetics of inflammatory markers, such as interleukin-6 (IL-6), during cold-water immersion have not been characterized. Objective To characterize serum IL-6 responses to water immersion at 2 temperatures and, therefore, to initiate further research into the multidimensional benefits of immersion and the evidence-based selection of specific, optimal immersion conditions by athletic trainers. Design Controlled laboratory study. Setting Human performance laboratory Patients or Other Participants Eight college-aged men (age = 22 ± 3 years, height = 1.76 ± 0.08 m, mass = 77.14 ± 9.77 kg, body fat = 10% ± 3%, and maximal oxygen consumption = 50.48 ± 4.75 mL·kg−1·min−1). Main Outcome Measures Participants were assigned randomly to receive either cold (11.70°C ± 2.02°C, n = 4) or warm (23.50°C ± 1.00°C, n = 4) water-bath conditions after exercise in the heat (temperature = 37°C, relative humidity = 52%) for 90 minutes or until volitional cessation. Results Whole-body cooling rates were greater in the cold water-bath condition for the first 6 minutes of water immersion, but during the 90-minute, postexercise recovery, participants in the warm and cold water-bath conditions experienced similar overall whole-body cooling. Heart rate responses were similar for both groups. Participants in the cold water-bath condition experienced an overall slight increase (30.54% ± 77.37%) in IL-6 concentration, and participants in the warm water-bath condition experienced an overall decrease (−69.76% ± 15.23%). Conclusions We have provided seed evidence that cold-water immersion is related to subtle IL-6 increases from postexercise values and that warmer water-bath temperatures might dampen this increase. Further research will elucidate any anti-inflammatory benefit associated with water-immersion treatment and possible multidimensional uses of cooling therapies. PMID:23182014
Water immersion recovery for athletes: effect on exercise performance and practical recommendations.
Versey, Nathan G; Halson, Shona L; Dawson, Brian T
2013-11-01
Water immersion is increasingly being used by elite athletes seeking to minimize fatigue and accelerate post-exercise recovery. Accelerated short-term (hours to days) recovery may improve competition performance, allow greater training loads or enhance the effect of a given training load. However, the optimal water immersion protocols to assist short-term recovery of performance still remain unclear. This article will review the water immersion recovery protocols investigated in the literature, their effects on performance recovery, briefly outline the potential mechanisms involved and provide practical recommendations for their use by athletes. For the purposes of this review, water immersion has been divided into four techniques according to water temperature: cold water immersion (CWI; ≤20 °C), hot water immersion (HWI; ≥36 °C), contrast water therapy (CWT; alternating CWI and HWI) and thermoneutral water immersion (TWI; >20 to <36 °C). Numerous articles have reported that CWI can enhance recovery of performance in a variety of sports, with immersion in 10-15 °C water for 5-15 min duration appearing to be most effective at accelerating performance recovery. However, the optimal CWI duration may depend on the water temperature, and the time between CWI and the subsequent exercise bout appears to influence the effect on performance. The few studies examining the effect of post-exercise HWI on subsequent performance have reported conflicting findings; therefore the effect of HWI on performance recovery is unclear. CWT is most likely to enhance performance recovery when equal time is spent in hot and cold water, individual immersion durations are short (~1 min) and the total immersion duration is up to approximately 15 min. A dose-response relationship between CWT duration and recovery of exercise performance is unlikely to exist. Some articles that have reported CWT to not enhance performance recovery have had methodological issues, such as failing to detect a decrease in performance in control trials, not performing full-body immersion, or using hot showers instead of pools. TWI has been investigated as both a control to determine the effect of water temperature on performance recovery, and as an intervention itself. However, due to conflicting findings it is uncertain whether TWI improves recovery of subsequent exercise performance. Both CWI and CWT appear likely to assist recovery of exercise performance more than HWI and TWI; however, it is unclear which technique is most effective. While the literature on the use of water immersion for recovery of exercise performance is increasing, further research is required to obtain a more complete understanding of the effects on performance.
The effect of head-down tilt and water immersion on intracranial pressure in nonhuman primates
NASA Technical Reports Server (NTRS)
Keil, Lanny C.; Mckeever, Kenneth H.; Skidmore, Michael G.; Hines, John; Severs, Walter B.
1992-01-01
Intracranial pressure (ICP) is investigated in primates during and after -6-deg head-down tilt (HDT) and immersion in water to examine the effects of the headward fluid shift related to spaceflight. Following the HDT the primates are subjected to head-out thermoneutral water immersion, and the ICP is subsequently measured. ICP is found to increase from 3.8 +/- 1.1 to 5.3 +/- 1.3 mm Hg during the horizontal control period. ICP stabilizes at -6.3 +/- 1.3 mm Hg and then increases to -2.2 +/- 1.9 mm Hg during partial immersion, and ICP subsequently returns to preimmersion levels after immersion. These data indicate that exposure to HDT or water immersion lead to an early sharp increase in ICP, and water immersion alone leads to higher ICP levels. A significant conclusion of the work is that the ICP did not approach pathological levels, and this finding is relevant to human spaceflight research.
Physiological response to water immersion: a method for sport recovery?
Wilcock, Ian M; Cronin, John B; Hing, Wayne A
2006-01-01
Recovery from exercise can be an important factor in performance during repeated bouts of exercise. In a tournament situation, where athletes may compete numerous times over a few days, enhancing recovery may provide a competitive advantage. One method that is gaining popularity as a means to enhance post-game or post-training recovery is immersion in water. Much of the literature on the ability of water immersion as a means to improve athletic recovery appears to be based on anecdotal information, with limited research on actual performance change. Water immersion may cause physiological changes within the body that could improve recovery from exercise. These physiological changes include intracellular-intravascular fluid shifts, reduction of muscle oedema and increased cardiac output (without increasing energy expenditure), which increases blood flow and possible nutrient and waste transportation through the body. Also, there may be a psychological benefit to athletes with a reduced cessation of fatigue during immersion. Water temperature alters the physiological response to immersion and cool to thermoneutral temperatures may provide the best range for recovery. Further performance-orientated research is required to determine whether water immersion is beneficial to athletes.
NASA Astrophysics Data System (ADS)
Dev, Pravin J.; Shanmugam, P.
2016-05-01
Underwater radiometers are generally calibrated in air using a standard source. The immersion factors are required for these radiometers to account for the change in the in-water measurements with respect to in-air due to the different refractive index of the medium. The immersion factors previously determined for RAMSES series of commercial radiometers manufactured by TriOS are applicable to clear oceanic waters. In typical inland and turbid productive coastal waters, these experimentally determined immersion factors yield significantly large errors in water-leaving radiances (Lw) and hence remote sensing reflectances (Rrs). To overcome this limitation, a semi-analytical method with based on the refractive index approximation is proposed in this study, with the aim of obtaining reliable Lw and Rrs from RAMSES radiometers for turbid and productive waters within coastal and inland water environments. We also briefly show the variation of pure water immersion factors (Ifw) and newly derived If on Lw and Rrs for clear and turbid waters. The remnant problems other than the immersion factor coefficients such as transmission, air-water and water-air Fresnel's reflectances are also discussed.
Voluntary respiratory control and cerebral blood flow velocity upon ice-water immersion.
Mantoni, Teit; Rasmussen, Jakob Højlund; Belhage, Bo; Pott, Frank Christian
2008-08-01
In non-habituated subjects, cold-shock response to cold-water immersion causes rapid reduction in cerebral blood flow velocity (approximately 50%) due to hyperventilation, increasing risk of syncope, aspiration, and drowning. Adaptation to the response is possible, but requires several cold immersions. This study examines whether thorough instruction enables non-habituated persons to attenuate the ventilatory component of cold-shock response. There were nine volunteers (four women) who were lowered into a 0 degrees C immersion tank for 60 s. Middle cerebral artery mean velocity (CBFV) was measured together with ventilatory parameters and heart rate before, during, and after immersion. Within seconds after immersion in ice-water, heart rate increased significantly from 95 +/- 8 to 126 +/- 7 bpm (mean +/- SEM). Immersion was associated with an elevation in respiratory rate (from 12 +/- 3 to 21 +/- 5 breaths, min(-1)) and tidal volume (1022 +/- 142 to 1992 +/- 253 ml). Though end-tidal carbon dioxide tension decreased from 4.9 +/- 0.13 to 3.9 +/- 0.21 kPa, CBFV was insignificantly reduced by 7 +/- 4% during immersion with a brief nadir of 21 +/- 4%. Even without prior cold-water experience, subjects were able to suppress reflex hyperventilation following ice-water immersion, maintaining the cerebral blood flow velocity at a level not associated with impaired consciousness. This study implies that those susceptible to accidental cold-water immersion could benefit from education in cold-shock response and the possibility of reducing the ventilatory response voluntarily.
ERDEMİR, Ugur; YİLDİZ, Esra; EREN, Meltem Mert; OZEL, Sevda
2013-01-01
Objectives: This study evaluated the effect of sports and energy drinks on the surface hardness of different composite resin restorative materials over a 1-month period. Material and Methods: A total of 168 specimens: Compoglass F, Filtek Z250, Filtek Supreme, and Premise were prepared using a customized cylindrical metal mould and they were divided into six groups (N=42; n=7 per group). For the control groups, the specimens were stored in distilled water for 24 hours at 37º C and the water was renewed daily. For the experimental groups, the specimens were immersed in 5 mL of one of the following test solutions: Powerade, Gatorade, X-IR, Burn, and Red Bull, for two minutes daily for up to a 1-month test period and all the solutions were refreshed daily. Surface hardness was measured using a Vickers hardness measuring instrument at baseline, after 1-week and 1-month. Data were statistically analyzed using Multivariate repeated measure ANOVA and Bonferroni's multiple comparison tests (α=0.05). Results: Multivariate repeated measures ANOVA revealed that there were statistically significant differences in the hardness of the restorative materials in different immersion times (p<0.001) in different solutions (p<0.001). The effect of different solutions on the surface hardness values of the restorative materials was tested using Bonferroni's multiple comparison tests, and it was observed that specimens stored in distilled water demonstrated statistically significant lower mean surface hardness reductions when compared to the specimens immersed in sports and energy drinks after a 1-month evaluation period (p<0.001). The compomer was the most affected by an acidic environment, whereas the composite resin materials were the least affected materials. Conclusions: The effect of sports and energy drinks on the surface hardness of a restorative material depends on the duration of exposure time, and the composition of the material. PMID:23739850
Effect of hydration on plasma volume and endocrine responses to water immersion
NASA Technical Reports Server (NTRS)
Harrison, M. H.; Keil, L. C.; Wade, C. A.; Silver, J. E.; Geelen, G.
1986-01-01
The effect of hydration status on early endocrine responses and on osmotic and intravascular volume changes during immersion was determined in humans undergoing successive periods of dehydration, immersion, rehydration, and immersion. Immersion caused an isotonic expansion of plasma volume, as well as suppression of plasma renin activity and aldosterone, which all occurred independently of hydration status. On the other hand, the concentration of plasma vasopressin (PVP) was found to decrease during dehydrated immersion, but not during rehydrated immersion. It is concluded that plasma tonicity is not a factor influencing PVP suppression during water immersion.
Using heart rate to prescribe physical exercise during head-out water immersion.
Kruel, Luiz F M; Peyré-Tartaruga, Leonardo A; Coertjens, Marcelo; Dias, Adriana B C; Da Silva, Rafael C; Rangel, Antônio C B
2014-01-01
The purpose of this study was to compare and correlate the effect of age group, sex, depth of water immersion, and the heart rate (HR) assessed out of the water on the HR behavior in individuals subjected to head-out water immersion. A total of 395 healthy individuals of both sexes, aged between 07 and 75 years, underwent vertical head-out water immersion. Heart rate was assessed out of the water in the supine and orthostatic (OHR) positions and at immersion depths corresponding to the ankle, knee, hip, umbilicus, xiphoid process, acromion, neck, and also the neck with the arms out of the water. The formula (ΔHR = OHR - HR immersion depth) was used to calculate the reduction in HR at each immersion depth. No age-based or sex-based differences in HR were found. The greater the depth of the water, the greater was the decrease in HR (p < 0.05); however, no differences were found between the HR values obtained below the depth corresponding to the umbilicus. Similarly, there was a significant relationship between OHR and ΔHR measured at levels below the depth corresponding to the umbilicus (e.g., xiphoid process level: r = 0.62; p < 0.05). Therefore, this study suggests to appropriately prescribe the intensity of water-based exercise intensity performed during vertical immersion: OHR should be measured before the individual entering the aquatic environment; ΔHR should be measured according to the depth at which exercise is to be performed, and we suggest an adaptation to Karvonen's HRmax prediction formula (predicted HRmax: 220 - age - ΔHR) to prescribe and control the intensity of the exercise performed during vertical immersion.
Influence of cold water immersion on limb and cutaneous blood flow at rest.
Gregson, Warren; Black, Mark A; Jones, Helen; Milson, Jordon; Morton, James; Dawson, Brian; Atkinson, Greg; Green, Daniel J
2011-06-01
Cold water immersion reduces exercise-induced muscle damage. Benefits may partly arise from a decline in limb blood flow; however, no study has comprehensively investigated the influence of different degrees of cooling undertaken via cold water immersion on limb blood flow responses. To determine the influence of cold (8°C) and cool (22°C) water immersion on lower limb and cutaneous blood flow. Controlled laboratory study. Nine men were placed in a semireclined position and lowered into 8°C or 22°C water to the iliac crest for two 5-minute periods interspersed with 2 minutes of nonimmersion. Rectal and thigh skin temperature, deep and superficial muscle temperature, heart rate, mean arterial pressure, thigh cutaneous blood velocity (laser Doppler), and superficial femoral artery blood flow (duplex ultrasound) were measured during immersion and for 30 minutes after immersion. Indices of vascular conductance were calculated (flux and blood flow/mean arterial pressure). Reductions in rectal temperature (8°C, 0.2° ± 0.1°C; 22°C, 0.1° ± 0.1°C) and thigh skin temperature (8°C, 6.2° ± 0.5°C; 22°C, 3.2° ± 0.2°C) were greater in 8°C water than in 22°C (P < .01). Femoral artery conductance was reduced to a similar extent immediately after immersion (~30%) and 30 minutes after immersion (~40%) under both conditions (P < .01). In contrast, there was less thigh cutaneous vasoconstriction during and after immersion in 8°C water compared with 22°C (P = .01). These data suggest that immersion at both temperatures resulted in similar whole limb blood flow but, paradoxically, more blood was distributed to the skin in the colder water. This suggests that colder temperatures may be associated with reduced muscle blood flow, which could provide an explanation for the benefits of cold water immersion in alleviating exercise-induced muscle damage in sports and athletic contexts. Colder water temperatures may be more effective in the treatment of exercise-induced muscle damage and injury rehabilitation because of greater reductions in muscle blood flow.
Cain, Christine L; Mauldin, Elizabeth A
2015-03-01
To describe clinical and histopathologic features of furunculosis in dogs following water immersion or exposure to grooming products. Retrospective case series. 22 dogs with skin lesions consistent with furunculosis and a history of water immersion or grooming prior to onset. Procedures-Information collected from the medical records of affected dogs included signalment, clinical signs, bathing or grooming procedure, diagnostic tests, treatment, and outcome. German Shepherd Dogs (4/22 [18%]) and Labrador Retrievers (4/22 [18%]) were most commonly affected. Skin lesions, particularly hemorrhagic pustules and crusts, were dorsally located in all dogs and occurred a median of 2 days (range, 1 to 7 days) following water immersion or exposure to grooming products. Twenty (91%) dogs were bathed at home or at a commercial grooming facility prior to lesion onset; 1 dog developed skin lesions following hydrotherapy on an underwater treadmill, and 1 dog developed peri-incisional skin lesions after surgery. Lethargy, signs of neck or back pain, and fever were common clinical signs. Pseudomonas aeruginosa was the most common bacterial isolate from dogs with bacteriologic culture performed on skin samples (10/14). The main histologic feature was acute follicular rupture in the superficial dermis with suppurative inflammation and dermal hemorrhage. Systemic antimicrobial treatment, particularly oral administration of fluoroquinolones, resulted in excellent clinical response in 16 of 22 (73%) dogs. Acute-onset furunculosis with characteristic clinical and histopathologic features in dogs following water immersion or exposure to grooming products was described. Knowledge of the historical and clinical features of this syndrome is essential for accurate diagnosis and appropriate treatment of affected dogs.
Comparison of water immersion and saline infusion as a means of inducing volume expansion in man
NASA Technical Reports Server (NTRS)
Epstein, M.; Pins, D. S.; Arrington, R.; Denunzio, A. G.; Engstrom, R.
1975-01-01
The study compares the natriuresis induced by head-out water immersion to that of a standard saline infusion and assesses the relative effectiveness of these two techniques as volume determinants of renal sodium and water handling in humans in a seated posture. The data obtained show that the volume stimulus of immersion is identical to that of standard saline-induced extracellular fluid volume expansion (ECVE) in normal seated subjects. The ability of head-out water immersion to induce a natriuresis without a concomitant increase in total blood volume and with a decrease in body weight suggests that water immersion may be preferred as an investigative tool for assessing the effects of ECVE in man.
McAdams, Wm.A.; Foss, M.H.
1958-08-12
A method of testing containers for leaks is described, particularly the testing of containers or cans in which the uranium slugs for nuelear reactors are jacketed. This method involves the immersion of the can in water under l50 pounds of pressure, then removing, drying, and coating the can with anhydrous copper sulfate. Amy water absorbed by the can under pressure will exude and discolor the copper sulfate in the area about the leak.
Tipton, M J; Eglin, C M; Golden, F S
1998-10-15
1. The initial respiratory and cardiac responses to cold water immersion are thought to be responsible for a significant number of open water deaths each year. Previous research has demonstrated that the magnitude of these responses can be reduced by repeated immersions in cold waterwhether the site of habituation is central or peripheral. 2. Two groups of subjects undertook two 3 min head-out immersions in stirred water at 10 C of the right-hand side of the body (R). Between these two immersions (3 whole days) the control group (n = 7) were not exposed to cold water, but the habituation group (n = 8) undertook a further six 3 min head-out immersions in stirred water at 10 C of the left-hand side of the body (L). 3. Repeated L immersions reduced (P < 0.01) the heart rate, respiratory frequency and volume responses. During the second R immersion a reduction (P < 0.05) in the magnitude of the responses evoked was seen in the habituation group but not in the control group, despite both groups having identical skin temperature profiles. 4. It is concluded that the mechanisms involved in producing habituation of the initial responses are located more centrally than the peripheral receptors.
Motion sickness increases the risk of accidental hypothermia.
Nobel, Gerard; Eiken, Ola; Tribukait, Arne; Kölegård, Roger; Mekjavic, Igor B
2006-09-01
Motion sickness (MS) has been found to increase body-core cooling during immersion in 28 degrees C water, an effect ascribed to attenuation of the cold-induced peripheral vasoconstriction (Mekjavic et al. in J Physiol 535(2):619-623, 2001). The present study tested the hypothesis that a more profound cold stimulus would override the MS effect on peripheral vasoconstriction and hence on the core cooling rate. Eleven healthy subjects underwent two separate head-out immersions in 15 degrees C water. In the control trial (CN), subjects were immersed after baseline measurements. In the MS-trial, subjects were rendered motion sick prior to immersion, by using a rotating chair in combination with a regimen of standardized head movements. During immersion in the MS-trial, subjects were exposed to an optokinetic stimulus (rotating drum). At 5-min intervals subjects rated their temperature perception, thermal comfort and MS discomfort. During immersion mean skin temperature, rectal temperature, the difference in temperature between the non-immersed right forearm and 3rd finger of the right hand (DeltaTff), oxygen uptake and heart rate were recorded. In the MS-trial, rectal temperature decreased substantially faster (33%, P < 0.01). Also, the DeltaTff response, an index of peripheral vasomotor tone, as well as the oxygen uptake, indicative of the shivering response, were significantly attenuated (P < 0.01 and P < 0.001, respectively) by MS. Thus, MS may predispose individuals to hypothermia by enhancing heat loss and attenuating heat production. This might have significant implications for survival in maritime accidents.
Transformational Play as a Curricular Scaffold: Using Videogames to Support Science Education
NASA Astrophysics Data System (ADS)
Barab, Sasha A.; Scott, Brianna; Siyahhan, Sinem; Goldstone, Robert; Ingram-Goble, Adam; Zuiker, Steven J.; Warren, Scott
2009-08-01
Drawing on game-design principles and an underlying situated theoretical perspective, we developed and researched a 3D game-based curriculum designed to teach water quality concepts. We compared undergraduate student dyads assigned randomly to four different instructional design conditions where the content had increasingly level of contextualization: (a) expository textbook condition, (b) simplistic framing condition, (c) immersive world condition, and (d) a single-user immersive world condition. Results indicated that the immersive-world dyad and immersive-world single user conditions performed significantly better than the electronic textbook group on standardized items. The immersive-world dyad condition also performed significantly better than either the expository textbook or the descriptive framing condition on a performance-based transfer task, and performed significantly better than the expository textbook condition on standardized test items. Implications for science education, and consistent with the goals of this special issue, are that immersive game-based learning environments provide a powerful new form of curriculum for teaching and learning science.
Siegel, Rodney; Maté, Joseph; Watson, Greig; Nosaka, Kazunori; Laursen, Paul B
2012-01-01
The purpose of this study was to compare the effects of pre-exercise ice slurry ingestion and cold water immersion on submaximal running time in the heat. On three separate occasions, eight males ran to exhaustion at their first ventilatory threshold in the heat (34.0 ± 0.1 ° C, 52 ± 3% relative humidity) following one of three 30 min pre-exercise manoeuvres: (1) ice slurry ingestion; (2) cold water immersion; or (3) warm fluid ingestion (control). Running time was longer following cold water immersion (56.8 ± 5.6 min; P = 0.008) and ice slurry ingestion (52.7 ± 8.4 min; P = 0.005) compared with control (46.7 ± 7.2 min), but not significantly different between cold water immersion and ice slurry ingestion (P = 0.335). During exercise, rectal temperature was lower with cold water immersion from 15 and 20 min into exercise compared with control and ice slurry ingestion, respectively, and remained lower until 40 min (P = 0.001). At exhaustion rectal temperature was significantly higher following ice slurry ingestion (39.76 ± 0.36 ° C) compared with control (39.48 ± 0.36 ° C; P = 0.042) and tended to be higher than cold water immersion (39.48 ± 0.34 ° C; P = 0.065). As run times were similar between conditions, ice slurry ingestion may be a comparable form of pre-cooling to cold water immersion.
Intrapericardial denervation: Responses to water immersion in rhesus monkeys
NASA Technical Reports Server (NTRS)
McKeever, Kenneth H.; Keil, Lanny C.; Sandler, Harold
1995-01-01
Eleven anesthetized rhesus monkeys were used to study cardiovascular, renal, and endocrine alterations associated with 120 min of head-out water immersion. Five animals underwent complete intrapericardial denervation using the Randall technique, while the remaining six monkeys served as intact controls. Each animal was chronically instrumented with an electromagnetic flow probe on the ascending aorta, a strain gauge pressure transducer implanted in the apex of the left ventricle (LV), and electrocardiogram leads anchored to the chest wall and LV. During immersion, LV end-diastolic pressure, urine flow, glomerular filtration rate, sodium excretion, and circulating atrial natriuretic peptide (ANP) each increased (P less than 0.05) for intact and denervated monkeys. There were no alterations in free water clearance in either group during immersion, yet fractional excretion of free water increased (P less than 0.05) in the intact monkeys. Plasma renin activity (PRA) decreased (P less than 0.05) during immersion in intact monkeys but not the denervated animals. Plasma vasopressin (PVP) concentration decreased (P less than 0.05) during the first 30 min of immersion in both groups but was not distinguishable from control by 60 min of immersion in denervated monkeys. These data demonstrate that complete cardiac denervation does not block the rise in plasma ANP or prevent the natriuresis associated with head-out water immersion. The suppression of PVP during the first minutes of immersion after complete cardiac denervation suggests that extracardiac sensing mechanisms associated with the induced fluid shifts may be responsible for the findings. water immersion; natriuresis; vasopressin; eardiae denervation; monkey
Seacoast stress corrosion cracking of aluminum alloys
NASA Technical Reports Server (NTRS)
Humphries, T. S.; Nelson, E. E.
1981-01-01
The stress corrosion cracking resistance of high strength, wrought aluminum alloys in a seacoast atmosphere was investigated and the results were compared with those obtained in laboratory tests. Round tensile specimens taken from the short transverse grain direction of aluminum plate and stressed up to 100 percent of their yield strengths were exposed to the seacoast and to alternate immersion in salt water and synthetic seawater. Maximum exposure periods of one year at the seacoast, 0.3 or 0.7 of a month for alternate immersion in salt water, and three months for synthetic seawater were indicated for aluminum alloys to avoid false indications of stress corrosion cracking failure resulting from pitting. Correlation of the results was very good among the three test media using the selected exposure periods. It is concluded that either of the laboratory test media is suitable for evaluating the stress corrosion cracking performance of aluminum alloys in seacoast atmosphere.
Narrow band imaging combined with water immersion technique in the diagnosis of celiac disease.
Valitutti, Francesco; Oliva, Salvatore; Iorfida, Donatella; Aloi, Marina; Gatti, Silvia; Trovato, Chiara Maria; Montuori, Monica; Tiberti, Antonio; Cucchiara, Salvatore; Di Nardo, Giovanni
2014-12-01
The "multiple-biopsy" approach both in duodenum and bulb is the best strategy to confirm the diagnosis of celiac disease; however, this increases the invasiveness of the procedure itself and is time-consuming. To evaluate the diagnostic yield of a single biopsy guided by narrow-band imaging combined with water immersion technique in paediatric patients. Prospective assessment of the diagnostic accuracy of narrow-band imaging/water immersion technique-driven biopsy approach versus standard protocol in suspected celiac disease. The experimental approach correctly diagnosed 35/40 children with celiac disease, with an overall diagnostic sensitivity of 87.5% (95% CI: 77.3-97.7). An altered pattern of narrow-band imaging/water immersion technique endoscopic visualization was significantly associated with villous atrophy at guided biopsy (Spearman Rho 0.637, p<0.001). Concordance of narrow-band imaging/water immersion technique endoscopic assessments was high between two operators (K: 0.884). The experimental protocol was highly timesaving compared to the standard protocol. An altered narrow-band imaging/water immersion technique pattern coupled with high anti-transglutaminase antibodies could allow a single guided biopsy to diagnose celiac disease. When no altered mucosal pattern is visible even by narrow-band imaging/water immersion technique, multiple bulbar and duodenal biopsies should be obtained. Copyright © 2014. Published by Elsevier Ltd.
High-rate lithium thionyl chloride cells
NASA Technical Reports Server (NTRS)
Goebel, F.
1982-01-01
A high-rate C cell with disc electrodes was developed to demonstrate current rates which are comparable to other primary systems. The tests performed established the limits of abuse beyond which the cell becomes hazardous. Tests include: impact, shock, and vibration tests; temperature cycling; and salt water immersion of fresh cells.
Karaman, Emel; Tuncer, Duygu; Firat, Esra; Ozdemir, Oguz Suleyman; Karahan, Sevilay
2014-05-01
To investigate the influence of different staining beverages on color stability, surface roughness and microhardness of silorane and methacrylate-based composite resins. Three different composite resins (Filtek Silorane, Filtek P60, Filtek Supreme XT) were tested. Thirty cylindrical specimens (10 × 2 mm) per material were prepared and polished with a series of aluminum-oxide polishing disks. Each group was then randomly subdivided into three groups according to the test beverages: distilled water (control), cola and coffee. The samples were immersed into different beverages for 15 days. Color, surface roughness and microhardness values were measured by a spectrophotometer, prophylometer and Vickers hardness device respectively, at baseline and after 15 days. The data were subjected to statistical analysis. Immersion in coffee resulted in a significant discoloration for all the composites tested, although the color change was lower in Filtek Silorane than that of MBCs (p < 0.05). All the composites tested showed similar surface roughness changes after immersion in different beverages (p > 0.05). Besides coffee caused more roughness change than others. Immersion in coffee caused highest microhardness change in Filtek Supreme XT (p < 0.05). Cola and coffee altered, to some degree, the color, surface roughness and/or microhardness of the tested resin composites, depending on the characteristics of the materials.
Whole body immersion and hydromineral homeostasis: effect of water temperature.
Jimenez, Chantal; Regnard, Jacques; Robinet, Claude; Mourot, Laurent; Gomez-Merino, Danielle; Chennaoui, Mounir; Jammes, Yves; Dumoulin, Gilles; Desruelle, Anne-Virginie; Melin, Bruno
2010-01-01
This experiment was designed to assess the effects of prolonged whole body immersion (WBI) in thermoneutral and cold conditions on plasma volume and hydromineral homeostasis.10 navy "combat swimmers" performed three static 6-h immersions at 34 degrees C (T34), 18 degrees C (T18) and 10 degrees C (T10). Rectal temperature, plasma volume (PV) changes, plasma proteins, plasma and urine ions, plasma osmolality, renin, aldosterone and antidiuretic hormone (ADH) were measured. Results show that compared to pre-immersion levels, PV decreased throughout WBI sessions, the changes being markedly accentuated in cold conditions. At the end of WBI, maximal PV variations were -6.9% at T34, -14.3% at T18, and -16.3% at T10. Plasma osmolality did not change during and after T34 immersion, while hyperosmolality was present at the end of T18 immersion and began after only 1 h of T10 immersion. In the three temperature conditions, significant losses of water (1.6-1.7 l) and salt (6-8 g) occurred and were associated with similar increases in osmolar and free water clearances. Furthermore, T18 and T10 immersions increased the glomerular filtration rate. There was little or no change in plasma renin and ADH, while the plasma level of aldosterone decreased equally in the three temperature conditions. In conclusion, our data indicate that cold water hastened PV changes induced by immersion, and increased the glomerular filtration rate, causing larger accumulated water losses. The iso-osmotic hypovolemia may impede the resumption of baseline fluid balance. Results are very similar to those repeatedly described by various authors during head-out water immersion.
Rotating shell eggs immersed in hot water for the purpose of pasteurization
USDA-ARS?s Scientific Manuscript database
Pasteurization of shell eggs for inactivation of Salmonella using hot water immersion can be used to improve their safety. The rotation of a shell egg immersed in hot water has previously been simulated by computational fluid dynamics (CFD); however, experimental data to verify the results do not ex...
Follett, P A; Sanxter, S S
2001-10-01
We determined whether immersion in 49 degrees C water for 20 min, a quarantine treatment developed for disinfestation of fruit flies in lychee, Litchi chinensis Sonn., and longan, Dimocarpus longan (Lourd.) Steud., exported from Hawaii, would also disinfest fruit of two species of Cryptophlebia. The pattern of tolerance to heat in Cryptophlebia illepida (Butler) was generally eggs < neonates < early instars = late instars < pupae. No C. illepida survived immersion for 16 or 20 min. Late fourth and fifth instars were determined to be the most tolerant stage that occurs in harvested fruit. Late instars of Cryptophlebia ombrodelta (Lower) were more tolerant of hot-water immersion than those of C. illepida, but no C. ombrodelta late instars survived immersion for 16 or 20 min. The hot water immersion quarantine treatment for fruit flies should effectively disinfest lychees and longans of any Cryptophlebia.
NASA Astrophysics Data System (ADS)
Favre, Audrey
Rubber composites are widely used in several engineering fields, such as automotive, and more recently for inflatable dams and other innovative underwater applications. These rubber materials are composed by an elastomeric matrix while the reinforcing phase is a synthetic fabric. Since these components are expected to operate several years in water environment, their durability must be guaranteed. The use of rubber materials immersed in water is not new, in fact, these materials have been studied for almost one century. However, the knowledge on reinforced rubber composites immersed several years in water is still limited. In this work, investigations on reinforced rubbers were carried out in the framework of a research project in partnership with Alstom and Hydro-Quebec. The objective of this study was to identify rubber composites that could be used under water for long periods. Various rubber composites with ethylene-propylene-diene monomer (EPDM), silicone, EPDM/silicone and polychloroprene (Neoprene) matrices reinforced with E-glass fabric were studied. Thus, these materials were exposed to an accelerated ageing at 85 °C underwater for periods varying from 14 to 365 days. For comparison purposes, they were also immersed and aged one year at room temperature (21 °C). The impact of accelerated aging was estimated through three different characterization methods. Scanning electron microscopy (SEM) was first used to assess the quality of fiber-matrix interface. Then, water absorption tests were performed to quantify the rate of water absorption during immersion. Finally the evolution of the mechanical properties was followed by the determination of Young's modulus (E) and ultimate stress (sigmau) using a dedicated traction test. This analysis allowed to point out that the quality of the fiber-matrix interface was the main factor influencing the drop of the mechanical properties and their durability. Moreover, it was noticed that this interface could be improved by using appropriate coupling agent as confirmed by the silicone composite with treated fabric. It was also observed that fiber-matrix interface could be a place where high stresses were localized because of differential swelling leading to an important loss of mechanical properties. The results revealed very different behaviors from one composite to another. The accelerated aging of EPDM/silicone and Neoprene composites led to a rapid diminution of mechanical properties in only 14 days. Conversely, silicone composites showed a 20 % increase of mechanical properties after 75 days of immersion. EPDM composites exhibited an important variability from one sample to another. It can be concluded from this study that composites made from silicone matrix with treated E-glass result in a better durability underwater. Keywords: composite elastomer, accelerated ageing, immersion in the water
Porosity of temporary denture soft liners containing antifungal agents.
Lima, Jozely Francisca Mello; Maciel, Janaína Gomes; Hotta, Juliana; Vizoto, Ana Carolina Pero; Honório, Heitor Marques; Urban, Vanessa Migliorini; Neppelenbroek, Karin Hermana
2016-01-01
To evaluate the porosity of a tissue conditioner (Softone) and a temporary resilient liner (Trusoft) modified by minimum inhibitory concentrations (MICs) of antifungal agents for Candida albicans biofilm. The porosity was measured by water absorption, based on exclusion of the plasticizer effect. Initially, it was determined by sorption isotherms that the adequate storage solution for specimens (65×10×3.3 mm) of both materials was 50% anhydrous calcium chloride (S50). Then, the porosity factor (PF) was calculated for the study groups (n=10) formed by specimens without (control) or with drug incorporation at MICs (nystatin: Ny-0.032 g, chlorhexidine diacetate: Chx-0.064 g, or ketoconazole: Ke-0.128 g each per gram of soft liner powder) after storage in distilled water or S50 for 24 h, seven and 14 d. Data were statistically analyzed by 4-way repeated measures ANOVA and Tukey's test (α=.05). Ke resulted in no significant changes in PF for both liners in water over 14 days (p>0.05). Compared with the controls, Softone and Trusoft PFs were increased at 14-day water immersion only after addition of Ny and Chx, and Chx, respectively (p<0.05). Both materials showed no significant changes in PF in up to 14 days of S50 immersion, compared with the controls (p>0.05). In all experimental conditions, Softone and Trusoft PFs were significantly lower when immersed in S50 compared with distilled water (p<0.05). The addition of antifungals at MICs resulted in no harmful effects for the porosity of both temporary soft liners in different periods of water immersion, except for Chx and Ny in Softone and Chx in Trusoft at 14 days. No deleterious effect was observed for the porosity of both soft liners modified by the drugs at MICs over 14 days of S50 immersion.
Effect of a 5-min cold-water immersion recovery on exercise performance in the heat.
Peiffer, J J; Abbiss, C R; Watson, G; Nosaka, K; Laursen, P B
2010-05-01
This study examined the effect of a 5-min cold-water immersion (14 degrees C) recovery intervention on repeated cycling performance in the heat. 10 male cyclists performed two bouts of a 25-min constant-paced (254 (22) W) cycling session followed by a 4-km time trial in hot conditions (35 degrees C, 40% relative humidity). The two bouts were separated by either 15 min of seated recovery in the heat (control) or the same condition with 5-min cold-water immersion (5th-10th minute), using a counterbalanced cross-over design (CP(1)TT(1) --> CWI or CON --> CP(2)TT(2)). Rectal temperature was measured immediately before and after both the constant-paced sessions and 4-km timed trials. Cycling economy and Vo(2) were measured during the constant-paced sessions, and the average power output and completion times were recorded for each time trial. Compared with control, rectal temperature was significantly lower (0.5 (0.4) degrees C) in cold-water immersion before CP(2) until the end of the second 4-km timed trial. However, the increase in rectal temperature (0.5 (0.2) degrees C) during CP(2) was not significantly different between conditions. During the second 4-km timed trial, power output was significantly greater in cold-water immersion (327.9 (55.7) W) compared with control (288.0 (58.8) W), leading to a faster completion time in cold-water immersion (6.1 (0.3) min) compared with control (6.4 (0.5) min). Economy and Vo(2) were not influenced by the cold-water immersion recovery intervention. 5-min cold-water immersion recovery significantly lowered rectal temperature and maintained endurance performance during subsequent high-intensity exercise. These data indicate that repeated exercise performance in heat may be improved when a short period of cold-water immersion is applied during the recovery period.
Barwood, Martin J; Burrows, Holly; Cessford, Jess; Goodall, Stuart
2016-02-01
Accidental cold-water immersion (CWI) evokes the life threatening cold shock response (CSR) which increases the risk of drowning. Consequently, the safety behaviour selected is critical in determining survival; the present advice is to 'float first' and remain stationary (i.e. rest). We examined whether leg only exercise (i.e., treading water; 'CWI-Kick') immediately on CWI could reduce the symptoms of the CSR, offset the reduction in cerebral blood flow that is known to occur and reduce the CSR's symptoms of breathlessness. We also examined whether perceptual responses instinctive to accidental CWI were exacerbated by this alternative behaviour. We contrasted CWI-Kick to a 'CWI-Rest' condition and a thermoneutral control (35°C); 'TN-Rest'. Seventeen participants were tested (9 males, 8 females). All immersions were standardised; water temperature in cold conditions (i.e., 12°C) was matched ±/0.5°C within participant. Middle cerebral artery blood flow velocity (MCAv) and cardiorespiratory responses were measured along with thermal perception (sensation and comfort) and dyspnoea. Data were analysed using repeated measures ANOVA (alpha level of 0.05). MCAv was significantly reduced in CWI-Rest (-6 (9)%; 1st minute of immersion) but was offset by leg only exercise immediately on cold water entry; CWI-Kick MCAv was never different to TN-Rest (-3 (16)% cf. 5 (4)%). All CWI cardiorespiratory and perceptual responses were different to TN-Rest but were not exacerbated by leg only exercise. Treading water may aid survival by offsetting the reduction in brain blood flow velocity without changing the instinctive behavioural response (i.e. perceptions). "Float first - and kick for your life" would be a suitable amendment to the water safety advice. Copyright © 2015 Elsevier Inc. All rights reserved.
Thermal Interface Evaluation of Heat Transfer from a Pumped Loop to Titanium-Water Thermosyphons
NASA Technical Reports Server (NTRS)
Jaworske, Donald A.; Sanzi, James L.; Gibson, Marc A.; Sechkar, Edward A.
2009-01-01
Titanium-water thermosyphons are being considered for use in the heat rejection system for lunar outpost fission surface power. Key to their use is heat transfer between a closed loop heat source and the heat pipe evaporators. This work describes laboratory testing of several interfaces that were evaluated for their thermal performance characteristics, in the temperature range of 350 to 400 K, utilizing a water closed loop heat source and multiple thermosyphon evaporator geometries. A gas gap calorimeter was used to measure heat flow at steady state. Thermocouples in the closed loop heat source and on the evaporator were used to measure thermal conductance. The interfaces were in two generic categories, those immersed in the water closed loop heat source and those clamped to the water closed loop heat source with differing thermal conductive agents. In general, immersed evaporators showed better overall performance than their clamped counterparts. Selected clamped evaporator geometries offered promise.
Severin, Anna C; Burkett, Brendan J; McKean, Mark R; Wiegand, Aaron N; Sayers, Mark G L
2017-01-01
Aquatic exercises can be used in clinical and sporting disciplines for both rehabilitation and sports training. However, there is limited knowledge on the influence of water immersion on the kinematics of exercises commonly used in rehabilitation and fitness programs. The aim of this study was to use inertial sensors to quantify differences in kinematics and movement variability of bodyweight squats, split squats, and single-leg squats performed on dry land and whilst immersed to the level of the greater trochanter. During two separate testing sessions, 25 active healthy university students (22.3±2.9 yr.) performed ten repetitions of each exercise, whilst tri-axial inertial sensors (100 Hz) recorded their trunk and lower body kinematics. Repeated-measures statistics tested for differences in segment orientation and speed, movement variability, and waveform patterns between environments, while coefficient of variance was used to assess differences in movement variability. Between-environment differences in segment orientation and speed were portrayed by plotting the mean difference ±95% confidence intervals (CI) throughout the tasks. The results showed that the depth of the squat and split squat were unaffected by the changed environment while water immersion allowed for a deeper single leg squat. The different environments had significant effects on the sagittal plane orientations and speeds for all segments. Water immersion increased the degree of movement variability of the segments in all exercises, except for the shank in the frontal plane, which showed more variability on land. Without compromising movement depth, the aquatic environment induces more upright trunk and shank postures during squats and split squats. The aquatic environment allows for increased squat depth during the single-leg squat, and increased shank motions in the frontal plane. Our observations therefore support the use of water-based squat tasks for rehabilitation as they appear to improve the technique without compromising movement depth.
2017-01-01
Aquatic exercises can be used in clinical and sporting disciplines for both rehabilitation and sports training. However, there is limited knowledge on the influence of water immersion on the kinematics of exercises commonly used in rehabilitation and fitness programs. The aim of this study was to use inertial sensors to quantify differences in kinematics and movement variability of bodyweight squats, split squats, and single-leg squats performed on dry land and whilst immersed to the level of the greater trochanter. During two separate testing sessions, 25 active healthy university students (22.3±2.9 yr.) performed ten repetitions of each exercise, whilst tri-axial inertial sensors (100 Hz) recorded their trunk and lower body kinematics. Repeated-measures statistics tested for differences in segment orientation and speed, movement variability, and waveform patterns between environments, while coefficient of variance was used to assess differences in movement variability. Between-environment differences in segment orientation and speed were portrayed by plotting the mean difference ±95% confidence intervals (CI) throughout the tasks. The results showed that the depth of the squat and split squat were unaffected by the changed environment while water immersion allowed for a deeper single leg squat. The different environments had significant effects on the sagittal plane orientations and speeds for all segments. Water immersion increased the degree of movement variability of the segments in all exercises, except for the shank in the frontal plane, which showed more variability on land. Without compromising movement depth, the aquatic environment induces more upright trunk and shank postures during squats and split squats. The aquatic environment allows for increased squat depth during the single-leg squat, and increased shank motions in the frontal plane. Our observations therefore support the use of water-based squat tasks for rehabilitation as they appear to improve the technique without compromising movement depth. PMID:28767683
Optimizing Cold Water Immersion for Exercise-Induced Hyperthermia: A Meta-analysis.
Zhang, Yang; Davis, Jon-Kyle; Casa, Douglas J; Bishop, Phillip A
2015-11-01
Cold water immersion (CWI) provides rapid cooling in events of exertional heat stroke. Optimal procedures for CWI in the field are not well established. This meta-analysis aimed to provide structured analysis of the effectiveness of CWI on the cooling rate in healthy adults subjected to exercise-induced hyperthermia. An electronic search (December 2014) was conducted using the PubMed and Web of Science. The mean difference of the cooling rate between CWI and passive recovery was calculated. Pooled analyses were based on a random-effects model. Sources of heterogeneity were identified through a mixed-effects model Q statistic. Inferential statistics aggregated the CWI cooling rate for extrapolation. Nineteen studies qualified for inclusion. Results demonstrate CWI elicited a significant effect: mean difference, 0.03°C·min(-1); 95% confidence interval, 0.03-0.04°C·min(-1). A conservative, observed estimate of the CWI cooling rate was 0.08°C·min(-1) across various conditions. CWI cooled individuals twice as fast as passive recovery. Subgroup analyses revealed that cooling was more effective (Q test P < 0.10) when preimmersion core temperature ≥38.6°C, immersion water temperature ≤10°C, ambient temperature ≥20°C, immersion duration ≤10 min, and using torso plus limbs immersion. There is insufficient evidence of effect using forearms/hands CWI for rapid cooling: mean difference, 0.01°C·min(-1); 95% confidence interval, -0.01°C·min(-1) to 0.04°C·min(-1). A combined data summary, pertaining to 607 subjects from 29 relevant studies, was presented for referencing the weighted cooling rate and recovery time, aiming for practitioners to better plan emergency procedures. An optimal procedure for yielding high cooling rates is proposed. Using prompt vigorous CWI should be encouraged for treating exercise-induced hyperthermia whenever possible, using cold water temperature (approximately 10°C) and maximizing body surface contact (whole-body immersion).
Zhang, Dongliang; Cao, Yanfei; Ma, Chengye; Chen, Shanfeng; Li, Hongjun
2017-03-29
There is a paradox when incorporating enzyme into an edible chitosan film that chitosan is dissolved in acid solution and enzyme activity is maintained under mild conditions. A method for maintaining the pH of the chitosan solution at 4-6 to prepare a chitosan film containing β-cyclodextrin, resveratrol-β-cyclodextrin inclusion (RCI), was developed, using glucamylase and acetic acid. A considerable amount of resveratrol was released by the glucamylase-incorporated film within 15 days, and the maximum amount released was 46% of the total resveratrol content. The highest resveratrol release ratio (released resveratrol/total resveratrol) was obtained in the film with 6 mL of RCI. Scratches and spores were generated on the surface of the glucamylase-added film immersed in water (GAFW) for 7 days because of β-cyclodextrin hydrolysis during film drying and water immersion. RCI and β-cyclodextrin were extruded from the film surface and formed teardrops, which were erased by water on the GAFW surface but appeared on the glucamylase-added film without water immersion (GAF). The bubbles generated by the reaction of acetic acid and residual sodium bicarbonate were observed in both glucamylase-free films immersed in water (GFFW) for 7 days and without water immersion (GFF). The FT-IR spectra illustrated that the covalent bond was not generated during water immersion and β-cyclodextrin hydrolysis. The crystal structure of chitosan was destroyed by water immersion and β-cyclodextrin hydrolysis, resulting in the lowest chitosan crystallization peak at 22°. The increasing of water holding capacity determined by EDX presented the following order: GAF, GFFW, GFF, and GAFW.
Garcia, Mauricio Koprowski; Rizzo, Limanara; Yazbek-Júnior, Paulo; Yutiyama, Daniela; Silva, Fabiola Jomar da; Matheus, Denise; Mastrocolla, Luiz Eduardo; Massad, Eduardo
2017-11-01
To compare responses to a cardiopulmonary exercise test on land versus on an underwater treadmill, to assess the cardiorespiratory performance of coronary artery disease patients while immersed in warm water and to compare with the performance of healthy individuals. The sample population consisted of 40 subjects, which included 20 coronary artery disease patients aged 63.7±8.89 years old, functional class I and II, according to the New York Hearth Association, and 20 healthy subjects aged 64.7±7.09 years old. The statistical significances were calculated through an ANOVA test with a (1 - β) power of 0.861. ClinicalTrials.gov: NCT00989248 (22). Significant differences were uncovered in coronary artery disease group regarding the variables heart beats (HB), (p>0.01), oxygen consumption (VO2), (p>0.01) and carbon dioxide production (VCO2) (p<0.01). Also, for the same group, in relation to the environment, water versus on land for HB, VO2, VCO2 and oxygen for each heart beat (VO2/HB) all of than (p<0.01). The stages for data collected featured the subject's performance throughout the experiment, and within the given context, variables rating of perceived exertion (RPE), HB, VO2, VCO2 and VO2/HB (p<0.01) showed significant interactions between test stages and environment. Additionally, there was a significant interaction between the etiology and the test stages for the variables HB, VO2 and VCO2 (p<0.01). Electrocardiographic changes compatible with myocardial ischemia or arrhythmia were not observed. The subjects exhibited lower scores on Borg's perceived exertion scale in the water than at every one of the test stages on land (p<0.01). This study show that a cardiopulmonary exercise test can be safely conducted in subjects in immersion and that the procedures, resources and equipment used yielded replicable and reliable data. Significant differences observed in water versus on land allow us to conclude that coronary artery disease patients are able to do physical exercise in water and that the physiological effects of immersion do not present any risk for such patients, as exercise was well tolerated by all subjects.
Beyer, Jessica; Moy, Philip; De Stasio, Bart
2011-01-01
Transport of aquatic invasive species (AIS) by boats traveling up rivers and streams is an important mechanism of secondary spread of AIS into watersheds. Because physical barriers to AIS movement also prevent navigation, alternate methods for preventing spread are necessary while allowing upstream navigation. One promising approach is to lift boats over physical barriers and then use hot water immersion to kill AIS attached to the hull, motor, or fishing gear. However, few data have been published on the acute upper thermal tolerance limits of potential invaders treated in this manner. To test the potential effectiveness of this approach for a planned boat lift on the Fox River of northeastern WI, USA, acute upper thermal limits were determined for three AIS, adult zebra mussels (Dreissena polymorpha), quagga mussels (Dreissena rostriformis bugensis), and spiny water fleas (Bythotrephes longimanus) from the local area employing temperatures from 32 to 54°C and immersion times from 1 to 20 min. Mortality was determined after immersion followed by a 20-min recovery period. Immersion at 43°C for at least 5 min was required to ensure 100% mortality for all three species, but due to variability in the response by Bythotrephes a 10 min immersion would be more reliable. Overall there were no significant differences between the three species in acute upper thermal limits. Heated water can be an efficient, environmentally sound, and cost effective method of controlling AIS potentially transferred by boats, and our results should have both specific and wide-ranging applications in the prevention of the spread of aquatic invasive species.
Effect of water-based recovery on blood lactate removal after high-intensity exercise.
Lucertini, Francesco; Gervasi, Marco; D'Amen, Giancarlo; Sisti, Davide; Rocchi, Marco Bruno Luigi; Stocchi, Vilberto; Benelli, Piero
2017-01-01
This study assessed the effectiveness of water immersion to the shoulders in enhancing blood lactate removal during active and passive recovery after short-duration high-intensity exercise. Seventeen cyclists underwent active water- and land-based recoveries and passive water and land-based recoveries. The recovery conditions lasted 31 minutes each and started after the identification of each cyclist's blood lactate accumulation peak, induced by a 30-second all-out sprint on a cycle ergometer. Active recoveries were performed on a cycle ergometer at 70% of the oxygen consumption corresponding to the lactate threshold (the control for the intensity was oxygen consumption), while passive recoveries were performed with subjects at rest and seated on the cycle ergometer. Blood lactate concentration was measured 8 times during each recovery condition and lactate clearance was modeled over a negative exponential function using non-linear regression. Actual active recovery intensity was compared to the target intensity (one sample t-test) and passive recovery intensities were compared between environments (paired sample t-tests). Non-linear regression parameters (coefficients of the exponential decay of lactate; predicted resting lactates; predicted delta decreases in lactate) were compared between environments (linear mixed model analyses for repeated measures) separately for the active and passive recovery modes. Active recovery intensities did not differ significantly from the target oxygen consumption, whereas passive recovery resulted in a slightly lower oxygen consumption when performed while immersed in water rather than on land. The exponential decay of blood lactate was not significantly different in water- or land-based recoveries in either active or passive recovery conditions. In conclusion, water immersion at 29°C would not appear to be an effective practice for improving post-exercise lactate removal in either the active or passive recovery modes.
Early Fluid and Protein Shifts in Men During Water Immersion
NASA Technical Reports Server (NTRS)
Hinghofer-Szalkay, H.; Harrison, M. H.; Greenleaf, J. E.
1987-01-01
High precision blood and plasma densitometry was used to measure transvascular fluid shifts during water immersion to the neck. Six men (28-49 years) undertook 30 min of standing immersion in water at 35.0 +/- 0.2 C; immersion was preceded by 30 min control standing in air at 28 +/- 1 C. Blood was sampled from an antecubital catheter for determination of Blood Density (BD), Plasma Density (PD), Haematocrit (Ht), total Plasma Protein Concentration (PPC), and Plasma Albumin Concentration (PAC). Compared to control, significant decreases (p less than 0.01) in all these measures were observed after 20 min immersion. At 30 min, plasma volume had increased by 11.0 +/- 2.8%; the average density of the fluid shifted from extravascular fluid into the vascular compartment was 1006.3 g/l; albumin moved with the fluid and its albumin concentration was about one-third of the plasma protein concentration during early immersion. These calculations are based on the assumption that the F-cell ratio remained unchanged. No changes in erythrocyte water content during immersion were found. Thus, immersion-induced haemodilution is probably accompanied by protein (mainly albumin) augmentation which accompanies the intra-vascular fluid shift.
Aoun, Georges; Cassia, Antoine; Berberi, Antoine
2015-06-01
Effective denture hygiene is important for patients suffering from denture stomatitis (DS). This study aimed to evaluate the efficacy of a solution containing 0.12% chlorhexidine (CHX) digluconate and 0.05% cetylpyridinium chloride (CPC) in eliminating Candida albicans colonizing dentures. Forty denture wearers (11 men, 29 women; age range 40 to 80 years) with clinical evidence of DS were randomly divided into two groups, one test and one control. The dentures of the test group were treated by immersion in a solution of 0.12% CHX and 0.05% CPC while those of the control group were immersed in distilled water. Swabs were collected from the fitting surfaces of the upper dentures prior and post cleaner use and examined mycologically. Reduction in the number of colony-forming units (CFU) of Candida albicans after immersion of the dentures in a solution of 0.12% CHX and 0.05% CPC was significantly greater than that of the control group. A solution of 0.12% CHX and 0.05% CPC tested as a product of disinfection of the acrylic dentures showed significant results after immersion of 8 night hours for 4 days.
9 CFR 325.13 - Denaturing procedures.
Code of Federal Regulations, 2012 CFR
2012-01-01
... water, 40 parts liquid detergent, and 40 parts oil of citronella, or other proprietary substance... immersion in a water bath, then immersing it for 1 minute in a solution of 0.022 percent FD&C yellow No. 5... immersion in a water bath, then dipping it in a solution of 0.0625 percent ferric acid; and (5) When meat...
9 CFR 325.13 - Denaturing procedures.
Code of Federal Regulations, 2013 CFR
2013-01-01
... water, 40 parts liquid detergent, and 40 parts oil of citronella, or other proprietary substance... immersion in a water bath, then immersing it for 1 minute in a solution of 0.022 percent FD&C yellow No. 5... immersion in a water bath, then dipping it in a solution of 0.0625 percent ferric acid; and (5) When meat...
9 CFR 325.13 - Denaturing procedures.
Code of Federal Regulations, 2014 CFR
2014-01-01
... water, 40 parts liquid detergent, and 40 parts oil of citronella, or other proprietary substance... immersion in a water bath, then immersing it for 1 minute in a solution of 0.022 percent FD&C yellow No. 5... immersion in a water bath, then dipping it in a solution of 0.0625 percent ferric acid; and (5) When meat...
Cold Stress and the Cold Pressor Test
ERIC Educational Resources Information Center
Silverthorn, Dee U.; Michael, Joel
2013-01-01
Temperature and other environmental stressors are known to affect blood pressure and heart rate. In this activity, students perform the cold pressor test, demonstrating increased blood pressure during a 1- to 2-min immersion of one hand in ice water. The cold pressor test is used clinically to evaluate autonomic and left ventricular function. This…
Intrapericardial Denervation: Responses to Water Immersion in Rhesus Monkeys
NASA Technical Reports Server (NTRS)
McKeever, Kenneth H.; Keil, Lanny C.; Sandler, Harold
1995-01-01
Eleven anesthetized rhesus monkeys were used to study cardiovascular, renal, and endocrine alterations associated with 120 min of head-out water immersion. Five animals underwent complete intrapericardial denervation using the Randall technique, while the remaining six monkeys served as intact controls. Each animal was chronically instrumented with an electromagnetic flow probe on the ascending aorta, a strain gauge pressure transducer implanted in the apex of the left ventricle (LV), and electrocardiogram leads anchored to the chest wall and LV. During immersion, LV end-diastolic pressure, urine flow, glomerular filtration rate, sodium excretion, and circulating atrial natriuretic peptide (ANP) each increased (P less than 0.05) for intact and denervated monkeys. There were no alterations in free water clearance in either group during immersion, yet fractional excretion of free water increased (P less than 0.05) in the intact monkeys. Plasma renin activity (PRA) decreased (P less than 0.05) during immersion in intact monkeys but not the denervated animals. Plasma vasopressin (PVP) concentration decreased (P less than 0.05) during the first 30 min of immersion in both groups but was not distinguishable from control by 60 min of immersion in denervated monkeys. These data demonstrate that complete cardiac denervation does not block the rise in plasma ANP or prevent the natriuresis associated with head-out water immersion. The suppression of PVP during the first minutes of immersion after complete cardiac denervation suggests that extracardiac sensing mechanisms associated with the induced fluid shifts may be responsible for the findings.
Acute whole-body cooling for exercise-induced hyperthermia: a systematic review.
McDermott, Brendon P; Casa, Douglas J; Ganio, Matthew S; Lopez, Rebecca M; Yeargin, Susan W; Armstrong, Lawrence E; Maresh, Carl M
2009-01-01
To assess existing original research addressing the efficiency of whole-body cooling modalities in the treatment of exertional hyperthermia. During April 2007, we searched MEDLINE, EMBASE, Scopus, SportDiscus, CINAHL, and Cochrane Reviews databases as well as ProQuest for theses and dissertations to identify research studies evaluating whole-body cooling treatments without limits. Key words were cooling, cryotherapy, water immersion, cold-water immersion, ice-water immersion, icing, fanning, bath, baths, cooling modality, heat illness, heat illnesses, exertional heatstroke, exertional heat stroke, heat exhaustion, hyperthermia, hyperthermic, hyperpyrexia, exercise, exertion, running, football, military, runners, marathoner, physical activity, marathoning, soccer, and tennis. Two independent reviewers graded each study on the Physiotherapy Evidence Database (PEDro) scale. Seven of 89 research articles met all inclusion criteria and a minimum score of 4 out of 10 on the PEDro scale. After an extensive and critical review of the available research on whole-body cooling for the treatment of exertional hyperthermia, we concluded that ice-water immersion provides the most efficient cooling. Further research comparing whole-body cooling modalities is needed to identify other acceptable means. When ice-water immersion is not possible, continual dousing with water combined with fanning the patient is an alternative method until more advanced cooling means can be used. Until future investigators identify other acceptable whole-body cooling modalities for exercise-induced hyperthermia, ice-water immersion and cold-water immersion are the methods proven to have the fastest cooling rates.
Kumar, M. Senthil; Ajay, R.; Miskeen Sahib, S. A.; Chittrarasu, M.; Navarasu, M.; Ragavendran, N.; Burhanuddin Mohammed, Omar Farooq
2017-01-01
Purpose of the Study: The aim of the study was to evaluate the difference in the color of microhybrid (MH) and nanofilled (NF) composite resins after 24 and 48 h in beverages such as red wine (RW), Coca-Cola, and distilled water. The specific objective of this study was to investigate the cumulative effect of the colorant solutions on the dental composites. Materials and Methods: MH and NF composite resins (A2 shade) were used in this current study. Sixty disk-shaped material specimens (10 mm in diameter × 2 mm in thickness) were prepared using a fiber mold (ring), with the desired dimensions. The specimen surfaces were polished using super-snap polishing system. Sixty specimens were divided into two groups of 30 each (Group I: MH resin composite; Group II: NF resin composite). Both the groups divided into six subgroups (Subgroup I: RW for 24 h [RW-24]; Subgroup II: RW for 48 h; Subgroup III: Coca-Cola for 24 h [CC-24]; Subgroup IV: Coca-Cola for 48 h [CC-48]; Subgroup V: Distilled water for 24 h [DW-24]; Subgroup VI: Distilled water for 48 h [DW-48]). All the samples were immersed in respective drinks for a period of 24 h, and color differences were measured using ultraviolet spectrophotometer. Once again, all the samples were immersed for another 24 h in the same drinks. After 48 h, the color change of the samples was measured. Measurements were made according to the CIE L × a × b × color space relative to the CIE standard illuminant D65. The color changes of the specimens were evaluated using the following formula: Statistical analysis was performed. The data were analyzed using the one-way ANOVA and t-test at a significance level of 0.05. Conclusion: Color stability of MH composite resin was found to be inferior than the NF resin composite irrespective of immersion medium and time. In RW, the color change observed was maximum for both composite resins followed by Coca-Cola. Immersing the resin composites in distilled water for 24 and 48 h had negligible color change. A 48-h immersion of both composite resins in all three immersion mediums showed greater color change than 24 h immersion. PMID:29284957
Kumar, M Senthil; Ajay, R; Miskeen Sahib, S A; Chittrarasu, M; Navarasu, M; Ragavendran, N; Burhanuddin Mohammed, Omar Farooq
2017-11-01
The aim of the study was to evaluate the difference in the color of microhybrid (MH) and nanofilled (NF) composite resins after 24 and 48 h in beverages such as red wine (RW), Coca-Cola, and distilled water. The specific objective of this study was to investigate the cumulative effect of the colorant solutions on the dental composites. MH and NF composite resins (A2 shade) were used in this current study. Sixty disk-shaped material specimens (10 mm in diameter × 2 mm in thickness) were prepared using a fiber mold (ring), with the desired dimensions. The specimen surfaces were polished using super-snap polishing system. Sixty specimens were divided into two groups of 30 each (Group I: MH resin composite; Group II: NF resin composite). Both the groups divided into six subgroups (Subgroup I: RW for 24 h [RW-24]; Subgroup II: RW for 48 h; Subgroup III: Coca-Cola for 24 h [CC-24]; Subgroup IV: Coca-Cola for 48 h [CC-48]; Subgroup V: Distilled water for 24 h [DW-24]; Subgroup VI: Distilled water for 48 h [DW-48]). All the samples were immersed in respective drinks for a period of 24 h, and color differences were measured using ultraviolet spectrophotometer. Once again, all the samples were immersed for another 24 h in the same drinks. After 48 h, the color change of the samples was measured. Measurements were made according to the CIE L × a × b × color space relative to the CIE standard illuminant D65. The color changes of the specimens were evaluated using the following formula: Statistical analysis was performed. The data were analyzed using the one-way ANOVA and t -test at a significance level of 0.05. Color stability of MH composite resin was found to be inferior than the NF resin composite irrespective of immersion medium and time. In RW, the color change observed was maximum for both composite resins followed by Coca-Cola. Immersing the resin composites in distilled water for 24 and 48 h had negligible color change. A 48-h immersion of both composite resins in all three immersion mediums showed greater color change than 24 h immersion.
Sea water Corrosion of Nickel based Plasma Spray Coating
NASA Astrophysics Data System (ADS)
Parida, M.; Nanda, S. P.; Bhuyan, S. K.; Mishra, S. C.
2018-03-01
Different types of erosion resistant coatings are applied/deposited on aero components, depending on the operating/working temperatures. Nickel based coating are applied on the air craft (compressor) components, which can sustain up to working temperature of 650°C. In the present investigation, to improve the compatibility between substrate (i.e. the machine component) and the top coat, application of bond coat is there. The application of Nickel based coating by thermal plasma spray technique has proven to be a satisfactory means of producing acceptable sealing surface with excellent abradability. Before the corrosion study, coated sample is subjected to hardness, thickness and porosity testing. Hence the result is being evaluated. The corrosion behavior of coating was studied by sea water immersion with a time period of 16 weeks. It is observed that, up to 9 weeks increase in weight of coating occurs in a sharp trend and then takes a decreasing trend. The weight gain of the samples has varied from 37.23% (with one week immersion in sea water) to a maximum of about 64.36% for six weeks immersion. Coating morphology and composition analysis of the coatings are studied using SEM and EDS. This behavior shows adsorption/deposition of the foreign particles with polygonal shape on the coating surface by sea water interaction. Foreign particles with polygonal shape deposited on the coating and with increase in immersion/treatment time, washing out of the deposited materials starts, which reflects the decreasing trend of weight gain of the specimen.
Scott, Chris G; Ducharme, Michel B; Haman, François; Kenny, Glen P
2004-11-01
We examined the effect of prior heating, by exercise and warm-water immersion, on core cooling rates in individuals rendered mildly hypothermic by immersion in cold water. There were seven male subjects who were randomly assigned to one of three groups: 1) seated rest for 15 min (control); 2) cycling ergometry for 15 min at 70% Vo2 peak (active warming); or 3) immersion in a circulated bath at 40 degrees C to an esophageal temperature (Tes) similar to that at the end of exercise (passive warming). Subjects were then immersed in 7 degrees C water to a Tes of 34.5 degrees C. Initial Tes cooling rates (initial approximately 6 min cooling) differed significantly among the treatment conditions (0.074 +/- 0.045, 0.129 +/- 0.076, and 0.348 +/- 0.117 degrees C x min(-1) for control, active, and passive warming conditions, respectively); however, secondary cooling rates (rates following initial approximately 6 min cooling to the end of immersion) were not different between treatments (average of 0.102 +/- 0.085 degrees C x min(-1)). Overall Tes cooling rates during the full immersion period differed significantly and were 0.067 +/- 0.047, 0.085 +/- 0.045, and 0.209 +/- 0.131 degrees C x min(-1) for control, active, and passive warming, respectively. These results suggest that prior warming by both active and, to a greater extent, passive warming, may predispose a person to greater heat loss and to experience a larger decline in core temperature when subsequently exposed to cold water. Thus, functional time and possibly survival time could be reduced when cold water immersion is preceded by whole-body passive warming, and to a lesser degree by active warming.
Changes in Landing Mechanics after Cold-Water Immersion
ERIC Educational Resources Information Center
Wang, He; Toner, Michael M.; Lemonda, Thomas J.; Zohar, Mor
2010-01-01
The purpose of this study was to investigate the influence of cold-water immersion on kinematics and kinetics during a drop-landing task. On four separate occasions, 9 men performed drop-landings from a 0.6-m platform to a force platform following 30-min immersion to the hip-joint in thermoneutral water (control; 34 [degrees]C) and in cold water…
Code of Federal Regulations, 2013 CFR
2013-01-01
... coloring, 40 parts water, 40 parts liquid detergent, and 40 parts oil of citronella, or other proprietary... dipping it in a solution of 0.0625 percent tannic acid, followed by immersion in a water bath, then... tannic acid for 1 minute followed by immersion in a water bath, then immersing it for 1 minute in a...
Code of Federal Regulations, 2014 CFR
2014-01-01
... coloring, 40 parts water, 40 parts liquid detergent, and 40 parts oil of citronella, or other proprietary... dipping it in a solution of 0.0625 percent tannic acid, followed by immersion in a water bath, then... tannic acid for 1 minute followed by immersion in a water bath, then immersing it for 1 minute in a...
Code of Federal Regulations, 2012 CFR
2012-01-01
... coloring, 40 parts water, 40 parts liquid detergent, and 40 parts oil of citronella, or other proprietary... dipping it in a solution of 0.0625 percent tannic acid, followed by immersion in a water bath, then... tannic acid for 1 minute followed by immersion in a water bath, then immersing it for 1 minute in a...
Sharan, Smitha; Kavitha, H R; Konde, Harish; Kalahasti, Deepthi
2012-05-01
To evaluate the effect of chemical disinfectant on the transverse strength of heat-polymerized acrylic resins subjected to mechanical and chemical polishing. A total of 256 rectangular specimens (65 * 10 * 3 mm) 128 per resin (Lucitone-199 and Acralyn-H) were fabricated. One side of each specimen was not polished and the other was either mechanically (n = 96) or chemically (n = 96) polished and immersed for 10, 30 and 60 minutes in 2% alkaline glutaraldehyde. Mechanically polished (n = 32) and chemically polished (n = 32) control specimens were immersed only in distilled water. The transverse strength (N/mm(2)) was tested for failure in a universal testing machine, at a crosshead speed of 5 mm/min. Data were statistically analyzed using 2-way ANOVA and Student t-test. chemical polishing resulted in significantly lower transverse strength values than mechanical polishing. Lucitone- 199 resin demonstrated the highest overall transverse strength for the materials tested. Heat-polymerized acrylic resins either mechanically or chemically polished, did not demonstrate significant changes in transverse strength during immersion in the disinfecting solution tested, regardless of time of immersion. Lucitone-199 resin demonstrated the highest overall transverse strength for the materials tested and significantly stronger than Acralyn-H with either type of polishing following immersion in 2% alkaline glutaraldehyde. There is a concern that immersion in chemical solutions often used for cleansing and disinfection of prostheses may undermine the strength and structure of denture base resins. In this study it was observed that, the transverse strength of samples of Lucitone-199 was higher than that of the samples of Acralyn-H. The chances of fracture of the denture made of Lucitone-199 are less than that of dentures made of Acralyn-H. The chemically polished dentures may be more prone to fracture than mechanically polished dentures.
Berry, Z Carter; Smith, William K
2013-11-01
Climate warming predicts changes to the frequency and height of cloud-immersion events in mountain communities. Threatened southern Appalachian spruce-fir forests have been suggested to persist because of frequent periods of cloud immersion. These relic forests exist on only seven mountaintop areas, grow only above ca. 1,500 m elevation (maximum 2,037 m), and harbor the endemic Abies fraseri. To predict future distribution, we examined the ecophysiological effects of cloud immersion on saplings of A. fraseri and Picea rubens at their upper and lower elevational limits. Leaf photosynthesis, conductance, transpiration, xylem water potentials, and general abiotic variables were measured simultaneously on individuals at the top (1,960 m) and bottom (1,510 m) of their elevation limits on numerous clear and cloud-immersed days throughout the growing season. The high elevation sites had 1.5 as many cloud-immersed days (75 % of days) as the low elevation sites (56 % of days). Cloud immersion resulted in higher photosynthesis, leaf conductance, and xylem water potentials, particularly during afternoon measurements. Leaf conductance remained higher throughout the day with corresponding increases in photosynthesis and transpiration, despite low photon flux density levels, leading to an increase in water potentials from morning to afternoon. The endemic A. fraseri had a greater response in carbon gain and water balance in response to cloud immersion. Climate models predict warmer temperatures with a decrease in the frequency of cloud immersion for this region, leading to an environment on these peaks similar to elevations where spruce-fir communities currently do not exist. Because spruce-fir communities may rely on cloud immersion for improved carbon gain and water conservation, an upslope shift is likely if cloud ceilings rise. Their ultimate survival will likely depend on the magnitude of changes in cloud regimes.
Panariello, Beatriz Helena Dias; Izumida, Fernanda Emiko; Moffa, Eduardo Buozi; Pavarina, Ana Claudia; Jorge, Janaina Habib; Giampaolo, Eunice Teresinha
2015-06-01
To investigate the cumulative effects of brushing (B) or immersion (I), using different cleansing agents, on the surface roughness, hardness and color stability of a heat-polymerized denture resin, Lucitone 550 (L), and a hard chairside reline resin, Tokuyama Rebase Fast II (T). A total of 316 specimens (10 x 2 mm) were fabricated. The specimens (n = 9) were divided into brushing or immersion groups according to the following agents: dentifrice/distilled water (D), 1% sodium hypochlorite (NaOCl), Corega Tabs (Pb), 1% chlorhexidine gluconate (Chx), and 0.2% peracetic acid (Ac). Brushing and immersion were tested independently. Assays were performed after 1, 3, 21, 45 and 90 brushing cycles or immersion of 10 seconds each. Data were evaluated statistically by repeated measures ANOVA. Tukey's honestly significant difference (HSD) post-hoc test was used to determine differences between means (α = 0.05). For L there was no statistically significant difference in roughness, except a significant decrease in roughness by brushing with D. T showed a significant effect on the roughness after 90 immersions with Ac. Hardness values decreased for L when specimens were immersed or brushed in NaOCl and Pb. The hardness of T decreased with increases in the repetitions (immersion or brushing), regardless of the cleaning method. Values of color stability for L resin showed significant color change after brushing with and immersion in Ac and Pb. Brushing with D exhibited a higher incidence of color change. For T there were no significant differences between cleaning agents and repetitions in immersion. A color change was noted after three brushings with the Ac, Chx, and D. Brushing with dentifrice decreased roughness of L. Immersion in or brushing with NaOCl and Pb decreased the hardness of L. For T, hardness decreased with increases in immersions or brushing. Color changes after the immersion in or brushing with cleaning agents were clinically acceptable according to National Bureau of Standards parameters for both resins.
Effects of vasopressin administration on diuresis of water immersion in normal humans
NASA Technical Reports Server (NTRS)
Epstein, M.; Denunzio, A. G.; Loutzenhiser, R. D.
1981-01-01
The influence of vasopressin suppression on the diuresis encountered during water immersion is investigated in studies on normal humans immersed to the neck. Six hydrated male subjects were studied on two occasions while undergoing 6 h of immersion without or during the administration of aqueous vasopressin for the initial 4 h. Neck immersion is found to result in a significant increase in urinary flow rate beginning in the first hour and persisting throughout the immersion. The administration of vasopressin markedly attenuated the diuretic response throughout the period of infusion, while cessation of vasopressin administration during the final 2 h of immersion resulted in a marked offset of the antidiuresis. Results thus support the view that the suppression of antidiuretic hormone contributes to the immersion diuresis of hydrated subjects.
Alterations in acid-base homeostasis during water immersion in normal man
NASA Technical Reports Server (NTRS)
Epstein, M.; Schneider, N. S.; Vaamonde, C. A.
1974-01-01
The effects of water immersion on renal bicarbonate and acid excretion were assessed in 10 normal male subjects. Immersion resulted in a highly significant progressive increase in the rate of sodium and bicarbonate excretion, and in urine pH. Immersion was also associated with a significant increase in urine P-CO2; this increase presupposes a maintained rate of hydrogen secretion in the distal tubular segment. The rapidity of onset of the bicarbonaturia (2 hrs of immersion) and the concomitant increase in urinary P-CO2 suggest that enhanced bicarbonate excretion of immersion cannot be completely accounted for by immersion-induced suppression of aldosterone, and that the natriuresis and bicarbonaturia of immersion is mediated in part by an increased proximal rejection of sodium and bicarbonate.
Body cooling in human males by cold-water immersion after vigorous exercise.
McDonald, A; Goode, R C; Livingstone, S D; Duffin, J
1984-03-01
Five male subjects were immersed to neck level in a whole-body water calorimeter (water temperature 19 degrees C) on two occasions. One immersion was preceded by 30 min of exercise on a treadmill at 80% of the subjects' maximum heart rate, while the other was preceded by no exercise (control). Ventilation, oxygen consumption, hand-grip strength, and heat loss (measured by calorimetry) results showed no significant differences between resting and exercise trials. Minute ventilation and oxygen consumption increased during the immersion but the magnitude of the increase varied among subjects. There was a significant decrease is isometric hand-grip strength after 30 min of immersion. Rectal temperatures fell faster (0.031 degree C +/- 0.004 degree C/min) for exercised subjects than for controls (0.019 degree C +/- 0.005 degree C/min) between 10 and 45 min of immersion (P less than 0.01). It appears that vigorous preimmersion exercise may shorten survival time in cold water due to an increase in cooling rate.
Gagnon, Dominique D; Pretorius, Thea; McDonald, Gerren; Kenny, Glen P; Giesbrecht, Gordon G
2013-06-01
Facial cooling can regulate reflexes of the dive response whereas further body cooling generally induces the cold-shock response. We examined the cardiovascular and ventilatory parameters of these responses during 3-min immersions of the head dorsum, face, and whole head in 17 degrees C water while breathing was maintained. From a horizontal position, the head was inserted into a temperature controlled immersion tank in which the water level could be changed rapidly. On four occasions, either the head dorsum, face or whole head (prone and supine) were exposed to water. Mean decrease in heart rate (14%) and increases in systolic (9%) and diastolic (5%) blood pressures were seen during immersion. Relative mean finger skin blood flow had an early transient decrease (31%) for 90 s and then returned to baseline values. A strong transient increase was seen in minute ventilation (92%) at 20 s of immersion via tidal volume (85%). There were no consistent differences between the head dorsum, face, and whole head for all variables in response to immersion. The cold-shock response (increased minute ventilation and tidal volume) predominated over the dive response in the initial moments of immersion only. The order of emergence of these responses provides further recommendation to avoid head submersion upon cold water entry. It is important to protect the face, with a facemask, and the head dorsum, with an insulative hood, in cold water.
Heydorn, S; Menné, T; Andersen, K E; Bruze, M; Svedman, C; Basketter, D; Johansen, J D
2003-06-01
Recently, we showed that 10 x 2% of consecutively patch-tested hand eczema patients had a positive patch test to a selection of fragrances containing fragrances relevant to hand exposure. In this study, we used repeated skin exposure to a patch test-positive fragrance allergen in patients previously diagnosed with hand eczema to explore whether immersion of fingers in a solution with or without the patch-test-positive fragrance allergen would cause or exacerbate hand eczema on the exposed finger. The study was double blinded and randomized. All participants had a positive patch test to either hydroxycitronellal or Lyral (hydroxyisohexyl 3-cyclohexene carboxaldehyde). Each participant immersed a finger from each hand, once a day, in a solution containing the fragrance allergen or placebo. During the first 2 weeks, the concentration of fragrance allergen in the solution was low (approximately 10 p.p.m.), whilst during the following 2 weeks, the concentration was relatively high (approximately 250 p.p.m.), imitating real-life exposure to a household product like dishwashing liquid diluted in water and the undiluted product, respectively. Evaluation was made using a clinical scale and laser Doppler flow meter. 3 of 15 hand eczema patients developed eczema on the finger immersed in the fragrance-containing solution, 3 of 15 on the placebo finger and 3 of 15 on both fingers. Using this experimental exposure model simulating real-life exposure, we found no association between immersion of a finger in a solution containing fragrance and development of clinically visible eczema on the finger in 15 participants previously diagnosed with hand eczema and with a positive patch test to the fragrance in question.
Cooper, Megan; McCutcheon, Helen; Warland, Jane
2017-10-01
Accessibility of water immersion for labour and/or birth is often dependent on the care provider and also the policies/guidelines that underpin practice. With little high quality research about the safety and practicality of water immersion, particularly for birth, policies/guidelines informing the practice may lack the evidence necessary to ensure practitioner confidence surrounding the option thereby limiting accessibility and women's autonomy. The aims of the study were to determine how water immersion policies and/or guidelines are informed, who interprets the evidence to inform policies/guidelines and to what extent the policy/guideline facilitates the option for labour and birth. Phase one of a three-phase mixed-methods study critically analysed 25 Australian water immersion policies/guidelines using critical discourse analysis. Policies/guidelines pertaining to the practice of water immersion reflect subjective opinions and views of the current literature base in favour of the risk-focused obstetric and biomedical discursive practices. Written with hegemonic influence, policies and guidelines impact on the autonomy of both women and practitioners. Policies and guidelines pertaining to water immersion, particularly for birth reflect opinion and varied interpretations of the current literature base. A degree of hegemonic influence was noted prompting recommendations for future maternity care policy and guidelines'. The Human Research Ethics Committee of the University of South Australia approved the research. Copyright © 2017 Australian College of Midwives. Published by Elsevier Ltd. All rights reserved.
Sackett, James R; Schlader, Zachary J; O'Leary, Morgan C; Chapman, Christopher L; Johnson, Blair D
2018-05-01
What is the central question of the study? Is central chemosensitivity blunted during thermoneutral head-out water immersion in healthy humans? What is the main finding and its importance? Central chemosensitivity is augmented during thermoneutral head-out water immersion in healthy men and women. Thus, we suggest that the central chemoreceptors do not contribute to CO 2 retention during head-out water immersion. Carbon dioxide retention occurs during water immersion. Therefore, we tested the hypothesis that central chemosensitivity to hypercapnia is blunted during 2 h of thermoneutral head-out water immersion (HOWI) in healthy young adults. Twenty-six participants (age 22 ± 2 years; body mass index 24 ± 3 kg m -2 ; 14 women) participated in two experimental visits: a HOWI visit (HOWI) and a dry time-control visit (Control). Central chemosensitivity was assessed via a rebreathing test at baseline, 10, 60, 90 and 120 min and after HOWI and Control. End-tidal CO 2 tension (P ET ,CO2), minute ventilation, blood pressure and heart rate were recorded continuously. The P ET ,CO2 increased from baseline throughout HOWI (peak increase at 120 min 2 ± 2 mmHg; P < 0.001), and the change in P ET ,CO2 was greater throughout HOWI than Control (P < 0.001). The change in minute and alveolar ventilation was not different throughout time (P ≥ 0.173) or between conditions (P ≥ 0.052). Central chemosensitivity was greater than at baseline throughout HOWI (peak increase 0.74 ± 1.01 l min -1 mmHg -1 at 120 min; P < 0.001), and the change in central chemosensitivity was greater throughout HOWI than Control (P ≤ 0.006). We also divided the cohort into tertiles based on baseline central chemosensitivity (i.e. Low, Intermediate and High) and compared Low versus High during HOWI. Low demonstrated an increase in P ET ,CO2 starting at 10 min (2 ± 3 mmHg; P < 0.001), whereas High did not exhibit an increase in P ET ,CO2 until 60 min (2 ± 2 mmHg; P = 0.018). These data indicate that CO 2 retention occurs throughout HOWI despite augmented central chemosensitivity and that having a high baseline central chemosensitivity might delay the onset of CO 2 retention. © 2018 The Authors. Experimental Physiology © 2018 The Physiological Society.
Heat Acclimation and Water-Immersion Deconditioning: Responses to Exercise
NASA Technical Reports Server (NTRS)
Shvartz, E.; Bhattacharya, A.; Sperinde, S. J.; Brock, P. J.; Sciaraffa, D.; Haines, R. F.; Greenleaf, J. E.
1977-01-01
Simulated subgravity conditions, such as bed rest and water immersion, cause a decrease in a acceleration tolerance (3, 4), tilt tolerance (3, 9, 10), work capacity (5, 7), and plasma volume (1, 8-10). Moderate exercise training performed during bed rest (4) and prior to water immersion (5) provides some protection against the adverse effects of deconditioning, but the relationship between exercise and changes due to deconditioning remains unclear. Heat acclimation increases plasma and interstitial volumes, total body water, stroke volume (11), and tilt tolerance (6) and may, therefore, be a more efficient method of ameliorating deconditioning than physical training alone. The present study was undertaken to determine the effects of heat acclimation and moderate physical training, performed in cool conditions, on water-immersion deconditioning.
A study on hardness behavior of geopolymer paste in different condition
NASA Astrophysics Data System (ADS)
Zainal, Farah Farhana; Hussin, Kamarudin; Rahmat, Azmi; Abdullah, Mohd Mustafa Al Bakri; Shamsudin, Shaiful Rizam
2016-07-01
This study has been conducted to understand the hardness behavior of geopolymer paste in different conditions; with and without being immersed in water. Geopolymer paste has been used nowadays as an alternative way to reduce global warming pollution by carbon dioxide (CO2) released to the air caused from the production of Ordinary Portland Cement (OPC). Geopolymer has many advantages such as high compressive strength, lower water absorption and lower porosity. Geopolymer paste in this study was made from a mixture of fly ash and alkaline activators. The alkaline activators that have been used were sodium hydroxide (NaOH) solution and sodium silicate (Na2SiO3) solution. Then the mixture was allowed to harden for 24hrs at ambient temperature and then placed in the oven for 24hrs with 60°C for the curing process. The hardness testing was conducted after a few months when the samples already achieved the optimum design. The samples were divided to two conditions; without immersion which was placed at ambient temperature (S1) and immersed in water for one week (S2). The samples then are divided into two at the center and testing was conducted into 4 parts which are part 1, part 2, part 3 and part 4. Various methods of non-destructively testing concrete and mortar have been in use for many years such as Vickers hardness test, Rockwell hardness test, Brinell hardness test and many more. The Rockwell hardness test method as defined in ASTM E-18 is the most commonly used hardness test method which is also used in this study. From the results, S1 has higher hardness value than S2 for all parts with the maximum value of S1 is 118.6 and the minimum value is 71.8. The maximum value of S2 is 114.4 and the minimum value is 0. The central part of the geopolymer paste also showed greater hardness values than the edge area of the samples.
Renal and cardiovascular responses to water immersion in trained runners and swimmers
NASA Technical Reports Server (NTRS)
Convertino, V. A.; Tatro, D. L.; Rogan, R. B.
1993-01-01
The purpose of this study was to determine if fluid-electrolyte, renal, hormonal, and cardiovascular responses during and after multi-hour water immersion were associated with aerobic training. Additionally, we compared these responses in those who trained in a hypogravic versus a 1-g environment. Seventeen men comprised three similarly aged groups: six long-distance runners, five competitive swimmers, and six untrained control subjects. Each subject underwent 5 h of immersion in water [mean (SE)] 36.0 (0.5) degrees C to the neck. Immediately before and at each hour of immersion, blood and urine samples were collected and analyzed for sodium (Na), potassium, osmolality, and creatinine (Cr). Plasma antidiuretic hormone and aldosterone were also measured. Hematocrits were used to calculate relative changes in plasma volume (% delta Vpl). Heart rate response to submaximal cycle ergometer exercise (35% peak oxygen uptake) was measured before and after water immersion. Water immersion induced significant increases in urine flow, Na clearance (CNa), and a 3-5% decrease in Vpl. Urine flow during immersion was greater (P < 0.05) in runners [2.4 (0.4) ml.min-1] compared to controls [1.3 (0.1) ml.min-1]. However, % delta Vpl, CCr, CNa and CH2O during immersion were not different (P > 0.05) between runners, swimmers, and controls. After 5 h of immersion, there was an increase (P < 0.05) in submaximal exercise heart rate of 9 (3) and 10 (3) beats.min-1 in both runners and controls, respectively, but no change (P > 0.05) was observed in swimmers.(ABSTRACT TRUNCATED AT 250 WORDS).
de Brito Fontana, Heiliane; Ruschel, Caroline; Dell'Antonio, Elisa; Haupenthal, Alessandro; Pereira, Gustavo Soares; Roesler, Helio
2018-04-01
The aim of this study was to analyze the effect of cadence, immersion level as well as body density on the vertical component (Fy max ) of ground reaction force (GRF) during stationary running (SR). In a controlled, laboratory study, thirty-two subjects ran at a wide range of cadences (85-210 steps/min) in water, immersed to the hip and to the chest, and on dry land. Fy max. was verified by a waterproof force measurement system and predicted based on a statistical model including cadence, immersion ratio and body density. The effect of cadence was shown to depend on the environment: while Fy max increases linearly with increasing cadence on land; in water, Fy max reaches a plateau at both hip and chest immersions. All factors analyzed, cadence, immersion level and body density affected Fy max significantly, with immersion (aquatic × land environment) showing the greatest effect. In water, different cadences may lead to bigger changes in Fy max than the changes obtained by moving subjects from hip to chest immersion. A regression model able to predict 69% of Fy max variability in water was proposed and validated. Cadence, Immersion and body density affect Fy max in a significant and non-independent way. Besides a model of potential use in the prescription of stationary running in water, our analysis provides insights into the different responses of GRF to changes in exercise parameters between land and aquatic environment. Copyright © 2018 Elsevier B.V. All rights reserved.
Effect of segmental, localized lower limb cooling on dynamic balance.
Montgomery, Roger E; Hartley, Geoffrey L; Tyler, Christopher J; Cheung, Stephen S
2015-01-01
This study aimed to determine the effect of cooling progressively greater portions of the lower extremities on dynamic balance and neuromuscular activation. Ten healthy males (22.8 ± 3.4 yr, 76.5 ± 9.1 kg) performed one room air temperature control (22.4°C ± 0.8°C) and three trials of cold water immersion at 12°C (lateral malleolus, ankle; lateral femoral epicondyle, knee; anterior superior iliac spine, hip) for 10 min before performing a unipedal balance test (Star Excursion Balance Test (SEBT)) with their dominant limb. Muscle activation of the vastus lateralis, biceps femoris, tibialis anterior, and lateral gastrocnemius was measured with surface EMG during the SEBT. Core temperature remained euthermic throughout all trials. Gastrocnemius temperature decreased from control (30.4°C ± 0.5°C) with knee (23.7°C ± 1.7°C) and hip immersion (22.4°C ± 1.0°C), whereas vastus lateralis temperature decreased from control (33.7°C ± 1.7°C) with hip immersion (27.3°C ± 2.0°C) (P < 0.01 for all comparisons). Cold water immersion influenced mean anterior and posterior reach distance on the SEBT in a dose-dependent fashion. Compared with those in control, mean anterior and posterior SEBT reach distances were not decreased with ankle (-1.38% and -0.74%, respectively) and knee immersion (-2.48% and -2.74%), whereas hip immersion significantly reduced SEBT by 4.73% and 4.05% (P < 0.05, d = 0.52-0.58). Muscle activation was largely unaffected as the lower extremities were cooled, with only the lateral gastrocnemius during the anterior SEBT approaching a decrease (P = 0.059). Cooling larger portions of the lower extremities progressively affect dynamic balance, and thermal protection strategies should focus on maintaining temperature in the large muscle mass of the thigh.
Gounder, Revathy; Vikas, B. V. J.
2016-01-01
Objective: To evaluate and compare the effect of 0.5% chlorhexidine gluconate, 1% sodium hypochlorite, and 2% glutaraldehyde by immersion and spray atomization technique on the linear dimensional stability of Jet bite, Aluwax and Ramitec interocclusal recording materials. Materials and Methods: Three representative materials: Jet bite (addition silicone), Aluwax and Ramitec (polyether) were mixed according to manufacturer's instructions and then specimens were prepared according to the specifications of ISO 4823. All the specimens except the control (distilled water) were treated with disinfectant solutions (0.5% chlorhexidine gluconate, 1% sodium hypochlorite, and 2% glutaraldehyde) for 30 and 60 min (n = 10) by spray and immersion technique. Once removed from the solutions, the test samples were washed in water for 15 s, dried and measured after 24 h 3 times using a measuring microscope with an accuracy of 0.0001 mm. Two-way ANOVA and Tukey's test with significance level of 5% were used to assess the statistical data (α = 0.05). Result: All groups showed no significant difference statistically, in linear dimension when disinfected for 30 min by spray or immersion technique. Polyether had significantly higher dimensional variation when immersed in sodium hypochlorite for 60 min. Addition silicone showed the least dimensional change which ranged from 0.024% to 0.05%, followed by polyether from 0.004% to 0.171% and Aluwax from 0.146% to 0.228%. Conclusion: To preserve the dimensions and surface of the recording materials and effective microbial elimination, restrictions should be applied in the method of disinfection and time duration. However, using the disinfectants either by spray or immersion technique, the dimensional change was <0.5% which was not clinically significant according to the American Dental Association specification no. 19 criteria within the first 24 h. PMID:27011733
Prolonged whole body immersion in cold water: hormonal and metabolic changes.
Smith, D J; Deuster, P A; Ryan, C J; Doubt, T J
1990-03-01
To characterize metabolic and hormonal responses during prolonged whole body immersion, 16 divers wearing dry suits completed four immersions in 5 degrees C water during each of two 5-day air saturation dives at 6.1 meters of sea water. One immersion began in the AM (1000 h) and one began in the PM (2200 h) to evaluate diurnal variations. Venous blood samples were obtained before and after completion of each immersion. Cortisol and ACTH levels demonstrated diurnal variation, with larger increases occurring after PM immersions. A greater than three-fold postimmersion increase occurred in norepinephrine (NE). There were significant increases in triiodothyronine (T3) uptake and epinephrine, but no change in T3, thyroxine, thyrotrophic hormone, and dopamine. Postimmersion free fatty acid levels increased 409% from preimmersion levels; glucose levels declined, and lactate increased significantly. Only changes in NE correlated significantly with changes in rectal temperature. In summary, when subjects are immersed in cold water for prolonged periods, with a slow rate of body cooling afforded by thermal protection and intermittent exercise, hormonal and metabolic changes occur that are similar in direction and magnitude to short-duration unprotected exposures. Except for cortisol and ACTH, none of the other measured variables exhibited diurnal alterations.
Thermal effects of dorsal head immersion in cold water on nonshivering humans.
Giesbrecht, Gordon G; Lockhart, Tamara L; Bristow, Gerald K; Steinman, Allan M
2005-11-01
Personal floatation devices maintain either a semirecumbent flotation posture with the head and upper chest out of the water or a horizontal flotation posture with the dorsal head and whole body immersed. The contribution of dorsal head and upper chest immersion to core cooling in cold water was isolated when the confounding effect of shivering heat production was inhibited with meperidine (Demerol, 2.5 mg/kg). Six male volunteers were immersed four times for up to 60 min, or until esophageal temperature = 34 degrees C. An insulated hoodless dry suit or two different personal floatation devices were used to create four conditions: 1) body insulated, head out; 2) body insulated, dorsal head immersed; 3) body exposed, head (and upper chest) out; and 4) body exposed, dorsal head (and upper chest) immersed. When the body was insulated, dorsal head immersion did not affect core cooling rate (1.1 degrees C/h) compared with head-out conditions (0.7 degrees C/h). When the body was exposed, however, the rate of core cooling increased by 40% from 3.6 degrees C/h with the head out to 5.0 degrees C/h with the dorsal head and upper chest immersed (P < 0.01). Heat loss from the dorsal head and upper chest was approximately proportional to the extra surface area that was immersed (approximately 10%). The exaggerated core cooling during dorsal head immersion (40% increase) may result from the extra heat loss affecting a smaller thermal core due to intense thermal stimulation of the body and head and resultant peripheral vasoconstriction. Dorsal head and upper chest immersion in cold water increases the rate of core cooling and decreases potential survival time.
NASA Astrophysics Data System (ADS)
Rohleder, N.; Wirth, D.; Fraßl, W.; Kowoll, R.; Schlemmer, M.; Vogler, S.; Kirsch, K. A.; Kirschbaum, C.; Gunga, H.-C.
2005-08-01
Limited data are available on the response of stress systems to microgravity. Increased activity of stress systems is reported during space flight, but unchanged or decreased activity during simulated microgravity. We here investigated the impact of head-out water immersion on the activity of the hypothalamus-pituitary-adrenal (HPA) axis and the sympathetic-adrenal-medullary (SAM) system.Eight healthy young men were exposed to a six-hour water immersion in a thermo neutral bath and a control condition. Saliva samples were taken before, during, and after interventions to assess cortisol as an index for HPA axis activity, and salivary α-amylase as an index for SAM system activity.Cortisol levels uniformly decreased during both conditions. Amylase levels increased during both conditions, but were significantly lower during the first half of water immersion compared to the control condition.In conclusion, the HPA axis is not influenced by simulated microgravity, while SAM system activity shows initial decreases during water immersion.
2016-04-01
Gerard Chaney, and Charles Pergantis Weapons and Materials Research Directorate, ARL Coatings, Corrosion, and Engineered Polymers Branch (CCEPB...SUBJECT TERMS single lap joint, adhesive, sample preparation, testing, database, metadata, material pedigree, ISO 16. SECURITY CLASSIFICATION OF: 17...temperature/water immersion conditioning test for lap-joint test specimens using the test tubes and convection oven method
Behavior of pure gallium in water and various saline solutions.
Horasawa, N; Nakajima, H; Takahashi, S; Okabe, T
1997-12-01
This study investigated the chemical stability of pure gallium in water and saline solutions in order to obtain fundamental knowledge about the corrosion mechanism of gallium-based alloys. A pure gallium plate (99.999%) was suspended in 50 mL of deionized water, 0.01%, 0.1% or 1% NaCl solution at 24 +/- 2 degrees C for 1, 7, or 28 days. The amounts of gallium released into the solutions were determined by atomic absorption spectrophotometry. The surfaces of the specimens were examined after immersion by x-ray diffractometry (XRD) and x-ray photoelectron spectroscopy (XPS). In the solutions containing 0.1% or more NaCl, the release of gallium ions into the solution was lowered when compared to deionized water after 28-day immersion. Gallium oxide monohydroxide was found by XRD on the specimens immersed in deionized water after 28-day immersion. XPS indicated the formation of gallium oxide/hydroxide on the specimens immersed in water or 0.01% NaCl solution. The chemical stability of pure solid gallium was strongly affected by the presence of Cl- ions in the aqueous solution.
Fluid shifts and endocrine responses during chair rest and water immersion in man
NASA Technical Reports Server (NTRS)
Greenleaf, J. E.; Shvartz, E.; Kravik, S.; Keil, L. C.
1980-01-01
The effects of external water pressure on intercompartmental fluid volume shifts and endocrine responses in man are investigated. Extracellular fluid volumes and plasma and urine electrolyte and endocrine responses of four male subjects were measured during eight hours of head-out water immersion and 16 hours of recovery bed rest and compared to responses obtained during eight hours of chair rest and 16 hours of bed rest without external hydrostatic pressure obtained in the same subjects five months later. Immersion is found to result in a substantial diuresis with respect to chair rest, accounted for by decreases in extracellular volume. A negative water balance during immersion and a positive water balance during chair rest were observed to be accompanied by a shift of extracellular volume to the intracellular compartment, as well as the suppression of plasma arginine vasopressin and renin activities in both regimes. The vasopressin and renin activity decreases are attributed to the increased central blood volume, and half of the plasma loss in immersed subjects is attributed to the effects of external water pressure.
Radtke, Thomas; Poerschke, Daniel; Wilhelm, Matthias; Trachsel, Lukas D; Tschanz, Hansueli; Matter, Friederike; Jauslin, Daniel; Saner, Hugo; Schmid, Jean-Paul
2016-04-01
The haemodynamic response to Finnish sauna and subsequent cold-water immersion in heart failure patients is unknown. Haemodynamic response to two consecutive Finnish sauna (80℃) exposures, followed by a final head-out cold-water immersion (12℃) was measured in 37 male participants: chronic heart failure (n = 12, 61.8 ± 9.2 years), coronary artery disease (n = 13, 61.2 ± 10.6 years) and control subjects (n = 12, 60.9 ± 8.9 years). Cardiac output was measured non-invasively with an inert gas rebreathing method prior to and immediately after the first sauna exposure and after cold-water immersion, respectively. Blood pressure was measured before, twice during and after sauna. The autonomic nervous system was assessed by power spectral analysis of heart rate variability. Total power, low-frequency and high-frequency components were evaluated. The low frequency/high frequency ratio was used as a marker of sympathovagal balance. Sauna and cold-water immersion were well tolerated by all subjects. Cardiac output and heart rate significantly increased in all groups after sauna and cold-water immersion (p < 0.05), except for coronary artery disease patients after sauna exposure. Systolic blood pressure during sauna decreased significantly in all groups with a nadir after 6 min (all p < 0.05). Cold-water immersion significantly increased systolic blood pressure in all groups (p < 0.05). No change in the low/high frequency ratio was found in chronic heart failure patients. In coronary artery disease patients and controls a prolonged increase in low frequency/high frequency ratio was observed after the first sauna exposure. Acute exposure to Finnish sauna and cold-water immersion causes haemodynamic alterations in chronic heart failure patients similarly to control subjects and in particular did not provoke an excessive increase in adrenergic activity or complex arrhythmias. © The European Society of Cardiology 2015.
Gradual surface degradation of restorative materials by acidic agents.
Hengtrakool, Chanothai; Kukiattrakoon, Boonlert; Kedjarune-Leggat, Ureporn
2011-01-01
The aim of this study was to investigate the effect of acidic agents on surface roughness and characteristics of four restorative materials. Fifty-two discs were created from each restorative material: metal-reinforced glass ionomer cement (Ketac-S), resin-modified glass ionomer cement (Fuji II LC), resin composite (Filtek Z250), and amalgam (Valiant-PhD); each disc was 12 mm in diameter and 2.5 mm thick. The specimens were divided into four subgroups (n=13) and immersed for 168 hours in four storage media: deionized water (control); citrate buffer solution; green mango juice; and pineapple juice. Surface roughness measurements were performed with a profilometer, both before and after storage media immersion. Surface characteristics were examined using scanning electron microscopy (SEM). Statistical significance among each group was analyzed using two-way repeated ANOVA and Tukey's tests. Ketac-S demonstrated the highest roughness changes after immersion in acidic agents (p<0.05), followed by Fuji II LC. Valiant-PhD and Filtek Z250 illustrated some minor changes over 168 hours. The mango juice produced the greatest degradation effect of all materials tested (p<0.05). SEM photographs demonstrated gradual surface changes of all materials tested after immersions. Of the materials evaluated, amalgam and resin composite may be the most suitable for restorations for patients with tooth surface loss.
Aoun, Georges; Saadeh, Maria; Berberi, Antoine
2015-08-01
Denture hygiene is an important factor in the prevention and treatment of denture stomatitis (DS). This study aimed to evaluate the efficacy of two different mouthwashes (chlorhexidine digluconate 0.12% and hexetidine 0.1%) in eliminating Candida albicans on dentures. A total of 60 denture wearers (20 men, 40 women; age range 40-80 years) with clinical evidence of DS were randomly divided into 2 test groups and 1 control group. The dentures of each test group were treated by immersion in one of the two mouthwashes while those of the control group were immersed in distilled water. Swab samples from the palatal surfaces of the upper dentures were collected before and after of cleaner use and examined mycologically. Reduction in the number of colony-forming units of Candida albicans after immersion of the dentures with chlorhexidine digluconate 0.12% was significantly greater than that of the group using hexetidine 0.1% and those of the control group. Hexetidine 0.1% solution tested for the first time as a product of disinfection of the acrylic dentures showed average results after immersion of 8 night hours for 4 days and was less effective than chlorhexidine digluconate 0.12%.
Influence of cold-water immersion on limb blood flow after resistance exercise.
Mawhinney, Chris; Jones, Helen; Low, David A; Green, Daniel J; Howatson, Glyn; Gregson, Warren
2017-06-01
This study determined the influence of cold (8°C) and cool (22°C) water immersion on lower limb and cutaneous blood flow following resistance exercise. Twelve males completed 4 sets of 10-repetition maximum squat exercise and were then immersed, semi-reclined, into 8°C or 22°C water for 10-min, or rested in a seated position (control) in a randomized order on different days. Rectal and thigh skin temperature, muscle temperature, thigh and calf skin blood flow and superficial femoral artery blood flow were measured before and after immersion. Indices of vascular conductance were calculated (flux and blood flow/mean arterial pressure). The colder water reduced thigh skin temperature and deep muscle temperature to the greatest extent (P < .001). Reductions in rectal temperature were similar (0.2-0.4°C) in all three trials (P = .69). Femoral artery conductance was similar after immersion in both cooling conditions, with both conditions significantly lower (55%) than the control post-immersion (P < .01). Similarly, there was greater thigh and calf cutaneous vasoconstriction (40-50%) after immersion in both cooling conditions, relative to the control (P < .01), with no difference between cooling conditions. These findings suggest that cold and cool water similarly reduce femoral artery and cutaneous blood flow responses but not muscle temperature following resistance exercise.
16 CFR 1203.13 - Test schedule.
Code of Federal Regulations, 2014 CFR
2014-01-01
... helmets, as designated in Table 1203.13, shall be tested for peripheral vision in accordance with § 1203... conditioned in the ambient, high temperature, low temperature, and water immersion environments as follows: helmets 1 and 5—ambient; helmets 2 and 7—high temperature; helmets 3 and 6—low temperature; and helmets 4...
16 CFR § 1203.13 - Test schedule.
Code of Federal Regulations, 2013 CFR
2013-01-01
... helmets, as designated in Table 1203.13, shall be tested for peripheral vision in accordance with § 1203... conditioned in the ambient, high temperature, low temperature, and water immersion environments as follows: helmets 1 and 5—ambient; helmets 2 and 7—high temperature; helmets 3 and 6—low temperature; and helmets 4...
16 CFR 1203.13 - Test schedule.
Code of Federal Regulations, 2011 CFR
2011-01-01
... helmets, as designated in Table 1203.13, shall be tested for peripheral vision in accordance with § 1203... conditioned in the ambient, high temperature, low temperature, and water immersion environments as follows: helmets 1 and 5—ambient; helmets 2 and 7—high temperature; helmets 3 and 6—low temperature; and helmets 4...
Water immersion and its computer simulation as analogs of weightlessness
NASA Technical Reports Server (NTRS)
Leonard, J. I.
1982-01-01
Experimental studies and computer simulations of water immersion are summarized and discussed with regard to their utility as analogs of weightlessness. Emphasis is placed on describing and interpreting the renal, endocrine, fluid, and circulatory changes that take place during immersion. A mathematical model, based on concepts of fluid volume regulation, is shown to be well suited to simulate the dynamic responses to water immersion. Further, it is shown that such a model provides a means to study specific mechanisms and pathways involved in the immersion response. A number of hypotheses are evaluated with the model related to the effects of dehydration, venous pressure disturbances, the control of ADH, and changes in plasma-interstitial volume. By inference, it is suggested that most of the model's responses to water immersion are plausible predictions of the acute changes expected, but not yet measured, during space flight. One important prediction of the model is that previous attempts to measure a diuresis during space flight failed because astronauts may have been dehydrated and urine samples were pooled over 24-hour periods.
Yu, Ya-Jen; Hearon, Keith; Wilson, Thomas S; Maitland, Duncan J
2011-08-01
The effect of moisture absorption on the glass transition temperature (T(g)) and stress/strain behavior of network polyurethane shape memory polymer (SMP) foams has been investigated. With our ultimate goal of engineering polyurethane SMP foams for use in blood contacting environments, we have investigated the effects of moisture exposure on the physical properties of polyurethane foams. To our best knowledge, this study is the first to investigate the effects of moisture absorption at varying humidity levels (non-immersion and immersion) on the physical properties of polyurethane SMP foams. The SMP foams were exposed to differing humidity levels for varying lengths of time, and they exhibited a maximum water uptake of 8.0% (by mass) after exposure to 100% relative humidity for 96 h. Differential scanning calorimetry results demonstrated that water absorption significantly decreased the T(g) of the foam, with a maximum water uptake shifting the T(g) from 67 °C to 5 °C. Samples that were immersed in water for 96 h and immediately subjected to tensile testing exhibited 100% increases in failure strains and 500% decreases in failure stresses; however, in all cases of time and humidity exposure, the plasticization effect was reversible upon placing moisture-saturated samples in 40% humidity environments for 24 h.
Yu, Ya-Jen; Hearon, Keith; Wilson, Thomas S.; Maitland, Duncan J.
2011-01-01
The effect of moisture absorption on the glass transition temperature (Tg) and stress/strain behavior of network polyurethane shape memory polymer (SMP) foams has been investigated. With our ultimate goal of engineering polyurethane SMP foams for use in blood contacting environments, we have investigated the effects of moisture exposure on the physical properties of polyurethane foams. To our best knowledge, this study is the first to investigate the effects of moisture absorption at varying humidity levels (non-immersion and immersion) on the physical properties of polyurethane SMP foams. The SMP foams were exposed to differing humidity levels for varying lengths of time, and they exhibited a maximum water uptake of 8.0% (by mass) after exposure to 100% relative humidity for 96 h. Differential scanning calorimetry results demonstrated that water absorption significantly decreased the Tg of the foam, with a maximum water uptake shifting the Tg from 67 °C to 5 °C. Samples that were immersed in water for 96 h and immediately subjected to tensile testing exhibited 100% increases in failure strains and 500% decreases in failure stresses; however, in all cases of time and humidity exposure, the plasticization effect was reversible upon placing moisture-saturated samples in 40% humidity environments for 24 h. PMID:21949469
NASA Astrophysics Data System (ADS)
Yu, Ya-Jen; Hearon, Keith; Wilson, Thomas S.; Maitland, Duncan J.
2011-08-01
The effect of moisture absorption on the glass transition temperature (Tg) and the stress/strain behavior of network polyurethane shape memory polymer (SMP) foams has been investigated. With our ultimate goal of engineering polyurethane SMP foams for use in blood-contacting environments, we have investigated the effects of moisture exposure on the physical properties of polyurethane foams. To the best of our knowledge, this study is the first to investigate the effects of moisture absorption at varying humidity levels (non-immersion and immersion) on the physical properties of polyurethane SMP foams. The SMP foams were exposed to differing humidity levels for varying lengths of time, and they exhibited a maximum water uptake of 8.0% (by mass) after exposure to 100% relative humidity for 96 h. Differential scanning calorimetry results demonstrated that water absorption significantly decreased the Tg of the foam, with a maximum water uptake shifting the Tg from 67 to 5 °C. Samples that were immersed in water for 96 h and immediately subjected to tensile testing exhibited 100% increases in failure strains and 500% decreases in failure stresses; however, in all cases of time and humidity exposure, the plasticization effect was reversible upon placing moisture-saturated samples in 40% humidity environments for 24 h.
Hundt, Matthias; Schreiber, Benjamin; Eckmann, Reiner; Lunestad, Bjørn Tore; Wünneman, Hannah; Schulz, Ralf
2016-02-01
Marking of fish otoliths with oxytetracycline and tetracycline is a widely used method to evaluate the effectiveness of stocking operations. Available protocols for the labeling of fish specify a number of factors influencing mark quality and potential risk for fish during marking. This study investigates the influence of water hardness on mortality of freshwater fish during marking with OTC. In order to pursue this question complexation of OTC with Mg(2+) and Ca(2+) cations was measured spectrophotometrically. Furthermore, zebrafish (Danio rerio) were immersed in OTC solutions (1200 mg/L; 48 h immersion) combined with varying levels of water hardness (5.5, 15.5, 25.5, 32.5°dH). The amount of OTC-Mg-Ca-complexes was positively correlated to water hardness. Moreover, it could be demonstrated that mortality of zebrafish during marking varied as a factor of water hardness. Highest mortalities occurred at the lowest (5.5°dH) and the highest (32.5°dH) tested levels during marking with OTC.
Sugajima, Y; Mitarai, G; Koeda, M; Moritani, T
1996-06-01
The effect of whole body water immersion on the recruitment order of hip flexor motor units was investigated in 11 male subjects. Intramuscular spike potentials were recorded, with fine bipolar wire electrodes, from the iliopsoas, the sartorius, the rectus femoris and the tensor fasciae latae during voluntary isometric contraction while the subjects were standing erect with the hip on the test side flexed to 60 degrees and the knee flexed to 120 degrees . Data were analysed by measuring the recruitment threshold in slow ramp contraction and by a computer-aided amplitude-frequency histogram of the spike potentials during short sustained contraction. The motor units were classified as low-amplitude units if they delivered spike potentials of less than 0.5 mV and high-amplitude units if the spike potentials exceeded 0.5 mV. In the ramp experiments, exposure to water immersion gave rise to a sudden increase in the recruitment thresholds of the low-amplitude units in all muscles, while in the recruitment thresholds of the high-amplitude units, the alterations differed among the muscles. The thresholds in the rectus femoris and tensor fasciae latae increased in the same direction as those of the low-amplitude units, while those in the iliopsoas and sartorius decreased in the opposite direction. The amplitude-frequency histograms clearly indicated that these different alterations occurred in all subjects, without exception. We concluded that unloading induced by water immersion changed the recruitment order of motor units during isometric contraction in the iliopsoas and sartorius, facilitating the recruitment of their larger motor units.
Porosity of temporary denture soft liners containing antifungal agents
Lima, Jozely Francisca Mello; Maciel, Janaína Gomes; Hotta, Juliana; Vizoto, Ana Carolina Pero; Honório, Heitor Marques; Urban, Vanessa Migliorini; Neppelenbroek, Karin Hermana
2016-01-01
ABSTRACT Incorporation of antifungals in temporary denture soft liners has been recommended for denture stomatitis treatment; however, it may affect their properties. Objective: To evaluate the porosity of a tissue conditioner (Softone) and a temporary resilient liner (Trusoft) modified by minimum inhibitory concentrations (MICs) of antifungal agents for Candida albicans biofilm. Material and Methods: The porosity was measured by water absorption, based on exclusion of the plasticizer effect. Initially, it was determined by sorption isotherms that the adequate storage solution for specimens (65×10×3.3 mm) of both materials was 50% anhydrous calcium chloride (S50). Then, the porosity factor (PF) was calculated for the study groups (n=10) formed by specimens without (control) or with drug incorporation at MICs (nystatin: Ny-0.032 g, chlorhexidine diacetate: Chx-0.064 g, or ketoconazole: Ke-0.128 g each per gram of soft liner powder) after storage in distilled water or S50 for 24 h, seven and 14 d. Data were statistically analyzed by 4-way repeated measures ANOVA and Tukey's test (α=.05). Results: Ke resulted in no significant changes in PF for both liners in water over 14 days (p>0.05). Compared with the controls, Softone and Trusoft PFs were increased at 14-day water immersion only after addition of Ny and Chx, and Chx, respectively (p<0.05). Both materials showed no significant changes in PF in up to 14 days of S50 immersion, compared with the controls (p>0.05). In all experimental conditions, Softone and Trusoft PFs were significantly lower when immersed in S50 compared with distilled water (p<0.05). Conclusions: The addition of antifungals at MICs resulted in no harmful effects for the porosity of both temporary soft liners in different periods of water immersion, except for Chx and Ny in Softone and Chx in Trusoft at 14 days. No deleterious effect was observed for the porosity of both soft liners modified by the drugs at MICs over 14 days of S50 immersion. PMID:27812615
Taenzler, Janina; Gale, Boyd; Zschiesche, Eva; Roepke, Rainer K A; Heckeroth, Anja R
2016-05-31
Fluralaner spot-on solution provides immediate and persistent efficacy against tick and flea infestations in dogs and cats for 12-weeks following topical administration. The active ingredient fluralaner is distributed systemically following transdermal absorption. Therefore, this study tested the hypothesis whether water-immersion or shampooing of dogs following administration of fluralaner spot-on solution has an impact on subsequent tick and flea efficacy. Thirty-two Beagle dogs were allocated to four study groups of 8 dogs each. On day 0, dogs in the 2 treatment groups received topical administration of fluralaner (Bravecto™ spot-on solution) according to label instructions. Dogs in the 2 corresponding control groups remained untreated. On days 3, 21, 49, and 77 dogs in one treatment group and control group were water-immersed for 2-5 min, while dogs in the other treatment group and control group were shampooed 6-8 min with a commercial foaming micro-emulsion, unscented product. On days 4, 28, 56, and 84 all dogs were co-infested with 50 ± 2 female and 10 ± 2 male Ixodes ricinus and 100 ± 4 Ctenocephalides felis, with tick and flea removal and counts 48 ± 2 h post-infestation. Efficacy against ticks and fleas was calculated for each assessment time point. No treatment-related adverse event was observed in any of the 16 dogs treated with fluralaner spot-on solution during the study. Efficacy against ticks at each assessment time point was between 99.7 and 100 % in the water-immersed group and between 99.2 and 100 % in the shampooed group. Efficacy against fleas was 100 % at each assessment time point as well in the water-immersed as the shampooed group. Tick and flea reduction in both treatment groups was significant at all assessment time points (p < 0.0001). Neither water-immersion nor shampooing after single topical administration of fluralaner spot-on solution had an impact on the excellent tick and flea efficacy over the 12-week recommended re-treatment interval.
Influence of pyridostigmine bromide on human thermoregulation during cold-water immersion
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cadarette, B.S.; Prusaczyk, W.K.; Sawka, M.N.
1991-03-11
This study examined the effects of an oral 30 mg dose of pyridostigmine bromide (PYR) on thermoregulatory and physiological responses during cold stress. Six men were immersed in chilled stirred water for up to 180 minutes; once 2 hours following ingestion of PYR and once 2 hours following ingestion of a placebo (CON). With PYR, mean ({plus minus} SD) red blood cell cholinesterase inhibition was 33 ({plus minus}12)% at 110 minutes post-ingestion. Cholinesterase inhibition was negatively related to lean body mass. Abdominal discomfort caused termination in 3 of 6 PYR experiments ({bar X} immersion time = 117 min) but inmore » no CON experiments ({bar X} immersion time = 142 min, p > 0.05). During immersion, metabolic rate increased significantly over pre-immersion levels, and increased with duration of immersion, but did not differ between conditions. PYR had no significant effect on rectal temperature, mean body temperature, thermal sensation, heart rate, or plasma cortisol concentration. It was concluded that a 30 mg dose of PYR does not increase susceptibility to hypothermia in humans immersed in cold-water; however, in combination with cold-stress, PYR may result in marked abdominal cramping and limit cold tolerance.« less
Isolated core vs. superficial cooling effects on virtual maze navigation.
Payne, Jennifer; Cheung, Stephen S
2007-07-01
Cold impairs cognitive performance and is a common occurrence in many survival situations. Altered behavior patterns due to impaired navigation abilities in cold environments are potential problems in lost-person situations. We investigated the separate effects of low core temperature and superficial cooling on a spatially demanding virtual navigation task. There were 12 healthy men who were passively cooled via 15 degrees C water immersion to a core temperature of 36.0 degrees C, then transferred to a warm (40 degrees C) water bath to eliminate superficial shivering while completing a series of 20 virtual computer mazes. In a control condition, subjects rested in a thermoneutral (approximately 35 degrees C) bath for a time-matched period before being transferred to a warm bath for testing. Superficial cooling and distraction were achieved by whole-body immersion in 35 degree water for a time-matched period, followed by lower leg immersion in 10 degree C water for the duration of the navigational tests. Mean completion time and mean error scores for the mazes were not significantly different (p > 0.05) across the core cooling (16.59 +/- 11.54 s, 0.91 +/- 1.86 errors), control (15.40 +/- 8.85 s, 0.82 +/- 1.76 errors), and superficial cooling (15.19 +/- 7.80 s, 0.77 +/- 1.40 errors) conditions. Separately reducing core temperature or increasing cold sensation in the lower extremities did not influence performance on virtual computer mazes, suggesting that navigation is more resistive to cooling than other, simpler cognitive tasks. Further research is warranted to explore navigational ability at progressively lower core and skin temperatures, and in different populations.
46 CFR 160.171-17 - Approval testing for adult size immersion suit.
Code of Federal Regulations, 2010 CFR
2010-10-01
..., except that each subject in the impact test described in § 160.171-17(c)(11) must not use more than one... test described in § 160.171-17(d). (c) Mobility and flotation tests. The mobility and flotation... equipment. The test must be conducted in calm water with a temperature between 0 °C (32 °F) and 2 °C (35.6...
46 CFR 160.171-17 - Approval testing for adult size immersion suit.
Code of Federal Regulations, 2011 CFR
2011-10-01
..., except that each subject in the impact test described in § 160.171-17(c)(11) must not use more than one... test described in § 160.171-17(d). (c) Mobility and flotation tests. The mobility and flotation... equipment. The test must be conducted in calm water with a temperature between 0 °C (32 °F) and 2 °C (35.6...
Pros and Cons of Using Water Immersion to Simulate Physiological Responses to Microgravity
NASA Technical Reports Server (NTRS)
Greenleaf, J. E.; Tomko, David L. (Technical Monitor)
1995-01-01
Head-out water immersion (HOI) has been employed as a remedial treatment for various ills and ailments for many millennia, and total body immersion even longer as protective encapsulation for the mammalian fetus. Two discrete differences between stimuli induced by true microgravity (10(exp -4) g) and HOI are readily apparent. External water pressure on the skin and accompanying negative pressure breathing cause blood to shift headward. Secondly, the gravitational force is ever present during immersion and microgravity, but its effect is essentially neutralized during Earth orbital flight. Thus, the physiological responses to immersion should not be expected to match those during microgravity. Immersion has been used mainly to study and understand kidney function and associated cardiovascular responses for control of body fluid volume and osmotic content, with some application to and simulation of microgravity responses. There is a plethora of data from human HOI studies, but relatively few controlled data from microgravity studies. In general, it appears that physiological responses occur more quickly with water immersion than in microgravity, but this may be due to less rigorous control (voluntary and involuntary) of the preflight state of crew members. The central venous pressure-vasopressin (Gauer-Henry) reflex control for fluid balance may not be of prime importance in microgravity. Gross functions such as reduced body weight and water, level of hypovolemia, decreased isokinetic strength, and lower nitrogen balance found during immersion are qualitatively similar in microgravity, but the mechanisms controlling these and other functions are, for the most part, unclear. Only acquisition of data from well-controlled microgravity experiments will resolve this discrepancy.
Vanderlei, Franciele M; de Albuquerque, Maíra C; de Almeida, Aline C; Machado, Aryane F; Netto, Jayme; Pastre, Carlos M
2017-10-01
Cold water immersion (CWI) is a commonly used recuperative strategy. However there is a lack of standardization of protocols considering the duration and temperature of application of the technique and the stress model. Therefore it is important to study the issue of dose response in a specific stress model. Thus the objective was to analyze and compare the effects of CWI during intense post-exercise recovery using different durations and temperatures of immersion. One hundred and five male individuals were divided into five groups: one control group (CG) and four recovery groups (G1: 5' at 9±1 °C; G2: 5' at 14±1 °C; G3: 15' at 9±1 °C; G4: 15' at 14±1 °C). The volunteers were submitted to an exhaustion protocol that consisted of a jump program and the Wingate Test. Immediately after the exhaustion protocol, the volunteers were directed to a tank with water and ice, where they were immersed for the recovery procedure, during which blood samples were collected for later lactate and creatine kinase (CK) analysis. Variables were collected prior to the exercise and 24, 48, 72, and 96 hours after its completion. For the CK concentration, 15 minutes at 14 °C was the best intervention option, considering the values at 72 hours after exercise, while for the moment of peak lactate an advantage was observed for immersion for 5 minutes at 14 °C. Regarding the perception of recovery, CWI for 5 minutes at 14 °C performed better long-term, from the time of the intervention to 96 hours post-exercise. For pain, no form of immersion responded better than the CG at the immediately post-intervention moment. There were no differences in behavior between the CWI intervention groups for the outcomes studied.
Habituation of the cold shock response may include a significant perceptual component.
Barwood, Martin J; Corbett, Jo; Wagstaff, Christopher R D
2014-02-01
Accidental immersion in cold water is a risk factor for many occupations. Habituation to cold-water immersion (CWI) is one practical means of reducing the cold shock response (CSR) on immersion. We investigated whether repeated thermoneutral water immersion (TWI) induced a perceptual habituation (i.e., could lessen perceived threat and anxiety) and consequently reduce the CSR on subsequent CWI. There were 12 subjects who completed seven 7-min head-out immersions. Immersions one and seven were CWls [15.0 (0.1) degrees C], and immersions two to six were TWI [34.9 (0.10) degrees C]. Anxiety 120-cm visual analogue scale) and the cardiorespiratory responses [heart rate (f(C)), respiratory frequency (f(R)), tidal volume (V(T)), and minute ventilation (V(E))] to immersion were measured throughout. Data were compared within subject between conditions using ANOVA to an alpha level of 0.05. Acute anxiety was significantly reduced after repeated exposure to the immersion scenario (i.e., TWI): CWI-1: 6.3 (4.4) cm; and CWI-2: 4.5 (4.0) cm [condition mean (SD)]. These differences did not influence the peak in the CSR. The f(C), f(R), and V(E) responses were similar between CWI-1 and CWI-2. V(T) response was significantly lower in CWI-2; mean (SD) across the immersion: CWI-1 1.27 (0.17) vs. CWI-2 1.11 0.21 L. Repeated TWI lessened the anxiety associated with CWI (perceptual habituation). This had a negligible effect on the primary components of the CSR, but did lower VT, which may reduce the volume of any aspirated water in an emergency situation. Reducing the threat appraisal of an environmental stressor may be a useful biproduct of survival training, thereby minimizing psychophysiological strain.
Effects of immersion water temperature on whole-body fluid distribution in humans.
Stocks, J M; Patterson, M J; Hyde, D E; Jenkins, A B; Mittleman, K D; Taylor, N A S
2004-09-01
In this study, we quantified acute changes in the intracellular and extracellular fluid compartments during upright neutral- and cold-water immersion. We hypothesized that, during short-term cold immersion, fluid shifts would be wholly restricted to the extracellular space. Seven males were immersed 30 days apart: control (33.3 degrees SD 0.6 degrees C); and cold (18.1 degrees SD 0.3 degrees C). Posture was controlled for 4 h prior to a 60-min seated immersion. Significant reductions in terminal oesophageal (36.9 degrees +/- 0.1 degrees -36.3 degrees +/- 0.1 degrees C) and mean skin temperatures (30.3 degrees +/- 0.3 degrees -23.0 degrees +/- 0.3 degrees C) were observed during the cold, but not the control immersion. Both immersions elicited a reduction in intracellular fluid [20.17 +/- 6.02 mL kg(-1) (control) vs. 22.72 +/- 9.90 mL kg(-1)], while total body water (TBW) remained stable. However, significant plasma volume (PV) divergence was apparent between the trials at 60 min [12.5 +/- 1.0% (control) vs. 6.1 +/- 3.1%; P < 0.05], along with a significant haemodilution in the control state (P < 0.05). Plasma atrial natriuretic peptide concentration increased from 18.0 +/- 1.6 to 58.7 +/- 15.1 ng L(-1) (P < 0.05) during cold immersion, consistent with its role in PV regulation. We observed that, regardless of the direction of the PV change, both upright immersions elicited reductions in intracellular fluid. These observations have two implications. First, one cannot assume that PV changes reflect those of the entire extracellular compartment. Second, since immersion also increases interstitial fluid pressure, fluid leaving the interstitium must have been rapidly replaced by intracellular water.
Garcia, Mauricio Koprowski; Rizzo, Limanara; Yazbek-Júnior, Paulo; Yutiyama, Daniela; da Silva, Fabiola Jomar; Matheus, Denise; Mastrocolla, Luiz Eduardo; Massad, Eduardo
2017-01-01
OBJECTIVE: To compare responses to a cardiopulmonary exercise test on land versus on an underwater treadmill, to assess the cardiorespiratory performance of coronary artery disease patients while immersed in warm water and to compare with the performance of healthy individuals. METHODS: The sample population consisted of 40 subjects, which included 20 coronary artery disease patients aged 63.7±8.89 years old, functional class I and II, according to the New York Hearth Association, and 20 healthy subjects aged 64.7±7.09 years old. The statistical significances were calculated through an ANOVA test with a (1 - β) power of 0.861. ClinicalTrials.gov: NCT00989248 (22). RESULTS: Significant differences were uncovered in coronary artery disease group regarding the variables heart beats (HB), (p>0.01), oxygen consumption (VO2), (p>0.01) and carbon dioxide production (VCO2) (p<0.01). Also, for the same group, in relation to the environment, water versus on land for HB, VO2, VCO2 and oxygen for each heart beat (VO2/HB) all of than (p<0.01). The stages for data collected featured the subject’s performance throughout the experiment, and within the given context, variables rating of perceived exertion (RPE), HB, VO2, VCO2 and VO2/HB (p<0.01) showed significant interactions between test stages and environment. Additionally, there was a significant interaction between the etiology and the test stages for the variables HB, VO2 and VCO2 (p<0.01). Electrocardiographic changes compatible with myocardial ischemia or arrhythmia were not observed. The subjects exhibited lower scores on Borg’s perceived exertion scale in the water than at every one of the test stages on land (p<0.01). CONCLUSION: This study show that a cardiopulmonary exercise test can be safely conducted in subjects in immersion and that the procedures, resources and equipment used yielded replicable and reliable data. Significant differences observed in water versus on land allow us to conclude that coronary artery disease patients are able to do physical exercise in water and that the physiological effects of immersion do not present any risk for such patients, as exercise was well tolerated by all subjects. PMID:29236912
McCarthy, Avina; Mulligan, James; Egaña, Mikel
2016-11-01
A brief cold water immersion between 2 continuous high-intensity exercise bouts improves the performance of the latter compared with passive recovery in the heat. We investigated if this effect is apparent in normothermic conditions (∼19 °C), employing an intermittent high-intensity exercise designed to reflect the work performed at the high-intensity domain in team sports. Fifteen young active men completed 2 exhaustive cycling protocols (Ex1 and Ex2: 12 min at 85% ventilatory threshold (VT) and then an intermittent exercise alternating 30-s at 40% peak power (P peak ) and 30 s at 90% P peak to exhaustion) separated by 15 min of (i) passive rest, (ii) 5-min cold-water immersion at 8 °C, and (iii) 10-min cold-water immersion at 8 °C. Core temperature, heart rate, rates of perceived exertion, and oxygen uptake kinetics were not different during Ex1 among conditions. Time to failure during the intermittent exercise was significantly (P < 0.05) longer during Ex2 following the 5- and 10-min cold-water immersions (7.2 ± 3.5 min and 7.3 ± 3.3 min, respectively) compared with passive rest (5.8 ± 3.1 min). Core temperature, heart rate, and rates of perceived exertion were significantly (P < 0.05) lower during most periods of Ex2 after both cold-water immersions compared with passive rest. The time constant of phase II oxygen uptake response during the 85% VT bout of Ex2 was not different among the 3 conditions. A postexercise, 5- to 10-min cold-water immersion increases subsequent intermittent high-intensity exercise compared with passive rest in normothermia due, at least in part, to reductions in core temperature, circulatory strain, and effort perception.
Cooper, Megan; Warland, Jane; McCutcheon, Helen
2018-06-01
There is little published research that has examined practitioners' views and experiences of pain relieving measures commonly used during labour and birth, particularly for non-pharmacological measures such as water immersion. Furthermore, there is minimal published research examining the process of policy and guideline development, that is, the translation of published research to usable practice guidance. The aims of phase three of a larger study were to explore midwives knowledge, experiences and support for the option of water immersion for labour and birth in practice and their involvement, if any, in development of policy and guidelines pertaining to the option. Phase three of a three phased mixed methods study included a web based survey of 234 Australian midwives who had facilitated and/or been involved in the development of policies and/or guidelines relating to the practice of water immersion. Midwives who participated in this study were supportive of both water immersion for labour and birth reiterating documented benefits of reduced pain, maternal relaxation and a positive birth experience. The most significant concerns were maternal collapse, the difficulty of estimating blood loss and postpartum haemorrhage whilst barriers included lack of accredited staff, lifting equipment and negative attitudes. Midwives indicated that policy/guideline documents limited their ability to facilitate water immersion and did not always to support women's informed choice. Midwives who participated in this study supported the practice of water immersion reiterating the benefits documented in the literature and minimal risk to the woman and baby. The Human Research Ethics Committee of the University of South Australia approved the research. Copyright © 2017 Australian College of Midwives. Published by Elsevier Ltd. All rights reserved.
Haupenthal, Alessandro; Fontana, Heiliane de Brito; Ruschel, Caroline; dos Santos, Daniela Pacheco; Roesler, Helio
2013-07-01
To analyze the effect of depth of immersion, running speed and gender on ground reaction forces during water running. Controlled laboratory study. Twenty adults (ten male and ten female) participated by running at two levels of immersion (hip and chest) and two speed conditions (slow and fast). Data were collected using an underwater force platform. The following variables were analyzed: vertical force peak (Fy), loading rate (LR) and anterior force peak (Fx anterior). Three-factor mixed ANOVA was used to analyze data. Significant effects of immersion level, speed and gender on Fy were observed, without interaction between factors. Fy was greater when females ran fast at the hip level. There was a significant increase in LR with a reduction in the level of immersion regardless of the speed and gender. No effect of speed or gender on LR was observed. Regarding Fx anterior, significant interaction between speed and immersion level was found: in the slow condition, participants presented greater values at chest immersion, whereas, during the fast running condition, greater values were observed at hip level. The effect of gender was only significant during fast water running, with Fx anterior being greater in the men group. Increasing speed raised Fx anterior significantly irrespective of the level of immersion and gender. The magnitude of ground reaction forces during shallow water running are affected by immersion level, running speed and gender and, for this reason, these factors should be taken into account during exercise prescription. Copyright © 2012 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
Environmental test program for superconducting materials and devices
NASA Technical Reports Server (NTRS)
Haertling, Gene; Randolph, Henry; Hsi, Chi-Shiung; Verbelyi, Darren
1991-01-01
This report is divided into two parts. The first dealing with work involved with Clemson University and the second with the results from Westinghouse/Savannah River. Both areas of work involved low noise, low thermal conductivity superconducting grounding links used in the NASA-sponsored Spectroscopy of the Atmosphere using Far Infrared Emission (SAFIRE) Project. Clemson prepared the links from YBa2Cu3O(7-x) superconductor tape that was mounted on a printed circuit board and encapsulated with epoxy resin. The Clemson program includes temperature vs. resistance, liquid nitrogen immersion, water immersion, thermal cycling, humidity, and radiation testing. The evaluation of the links under a long term environmental test program is described. The Savannah River program includes gamma irradiation, vibration, and long-term evaluation. The progress made in these evaluations is discussed.
An investigation on defect-generation conditions in immersion lithography
NASA Astrophysics Data System (ADS)
Tomita, Tadatoshi; Shimoaoki, Takeshi; Enomoto, Masashi; Kyoda, Hideharu; Kitano, Junichi; Suganaga, Toshifumi
2006-03-01
As a powerful candidate for a lithography technique that can accommodate the scaling-down of semiconductors, 193-nm immersion lithography-which realizes a high numerical aperture (NA) and uses deionized water as the medium between the lens and wafer in the exposure system-has been developing at a rapid pace and has reached the stage of practical application. In regards to defects that are a cause for concern in the case of 193-nm immersion lithography, however, many components are still unclear and many problems remain to be solved. It has been pointed out, for example, that in the case of 193-nm immersion lithography, immersion of the resist film in deionized water during exposure causes infiltration of moisture into the resist film, internal components of the resist dissolve into the deionized water, and residual water generated during exposure affects post-processing. Moreover, to prevent this influence of directly immersing the resist in de-ionized water, application of a protective film is regarded as effective. However, even if such a film is applied, it is still highly likely that the above-mentioned defects will still occur. Accordingly, to reduce these defects, it is essential to identify the typical defects occurring in 193-nm immersion lithography and to understand the condition for generation of defects by using some kinds of protective films and resist materials. Furthermore, from now onwards, with further scaling down of semiconductors, it is important to maintain a clear understanding of the relation between defect-generation conditions and critical dimensions (CD). Aiming to extract typical defects occurring in 193-nm immersion lithography, the authors carried out a comparative study with dry exposure lithography, thereby confirming several typical defects associated with immersion lithography. We then investigated the conditions for generation of defects in the case of some kinds of protective films. In addition to that, by investigating the defect-generation conditions and comparing the classification data between wet and dry exposure, we were able to determine the origin of each particular defect involved in immersion lithography. Furthermore, the comparison of CD for wet and dry processing could indicate the future defectivity levels to be expected with shrinking immersion process critical dimensions.
Water immersion during labor and birth: is there an extra cost for hospitals?
Poder, Thomas G
2017-06-01
Water immersion during labor and birth is growing in popularity, and many hospitals are now considering offering this service to laboring women. Some advantages of water immersion are demonstrated, but others remain uncertain, and particularly, few studies have examined the financial impact of such a device on hospitals. This study simulated what could be the extra cost of water immersion for hospitals. Clinical outcomes were drawn from the results of systematic reviews already published, and cost units were those used in the Quebec health network. A decision tree was used with microsimulations of representative laboring women. Sensitivity analyses were performed as regards analgesic use and labor duration. Microsimulations indicated an extra cost between $166.41 and $274.76 (2014 Canadian dollars) for each laboring woman as regards the scenario considered. The average extra cost was $221.12 (95% confidence interval, 219.97-222.28). While water immersion allows better clinical outcomes, implementation and other costs are higher than the savings generated, which leads to a small extra cost to allow women to potentially have more relaxation and less pain. © 2016 John Wiley & Sons, Ltd.
NASA Astrophysics Data System (ADS)
Raya, Indah; Ramdani, Nurfika; Karim, Abd.; Muin, Musrizal
2018-03-01
Research of modifying particle board has been prepared by mixing of pinus merkusii sawdust and rice husk, where used of adhesive base on Boiled Soybean Water (BSW) has been done. The research utilize the rise husk and sawdust pines mixed, and used of a renewable and environmental adhesive to replace the toxic and carcinogenic one. The testing of adhesive included are; colour, pH, solid contain, gelatination time, density and viscosity. Result showed yellowish colour, 10 of pH, 44.70 % of solid contained, 56.29 minutes of gelatination time, and 1.1656 g/cm3 and 182.4387 cP of viscocity respectively. While the particle boards testing include are density, moisture, immersion, thickness, Modulus of Rapture (MOR) and Modulus of Elasticity (MOE). The particle board best ratio it was 1:4 (Rice husk: pinus merkusii sawdust). Result of each parameter are, 0.7735 g/cm3 of density, 5.79 % of moisture, however the immersion for 2 hours is 26.90 % and immersion for 24 hours is 39.77 %, 101.1592 kg/cm2 of MOR and 18,248.3063 kg/cm2of MOE. The summary, the adhesive based on SNI 06-4567-1998 and the particle board based on SNI 03-2105-1996
Thermal insulation and body temperature wearing a thermal swimsuit during water immersion.
Wakabayashi, Hitoshi; Hanai, Atsuko; Yokoyama, Shintaro; Nomura, Takeo
2006-09-01
This study evaluated the effects of a thermal swimsuit on body temperatures, thermoregulatory responses and thermal insulation during 60 min water immersion at rest. Ten healthy male subjects wearing either thermal swimsuits or normal swimsuits were immersed in water (26 degrees C or 29 degrees C). Esophageal temperature, skin temperatures and oxygen consumption were measured during the experiments. Metabolic heat production was calculated from oxygen consumption. Heat loss from skin to the water was calculated from the metabolic heat production and the change in mean body temperature during water immersion. Total insulation and tissue insulation were estimated by dividing the temperature difference between the esophagus and the water or the esophagus and the skin with heat loss from the skin. Esophageal temperature with a thermal swimsuit was higher than that with a normal swimsuit at the end of immersion in both water temperature conditions (p<0.05). Oxygen consumption, metabolic heat production and heat loss from the skin were less with the thermal swimsuit than with a normal swimsuit in both water temperatures (p<0.05). Total insulation with the thermal swimsuit was higher than that with a normal swimsuit due to insulation of the suit at both water temperatures (p<0.05). Tissue insulation was similar in all four conditions, but significantly higher with the thermal swimsuit in both water temperature conditions (p<0.05), perhaps due to of the attenuation of shivering during immersion with a thermal swimsuit. A thermal swimsuit can increase total insulation and reduce heat loss from the skin. Therefore, subjects with thermal swimsuits can maintain higher body temperatures than with a normal swimsuit and reduce shivering thermo-genesis.
Effect of cavity preparation on the flexural strengths of acrylic resin repairs
ELHADIRY, Safa Salim; YUNUS, Norsiah; ARIFFIN, Yusnidar Tajul
2010-01-01
Objective To investigate the effect of cavity preparation on the flexural strength of heat-curing denture resin when repaired with an auto-curing resin. Material and methods Ninety-six rectangular specimens (64x10x2.5 mm) prepared from heat-curing denture base resin (Meliodent) were randomly divided into four groups before repair. One group was left intact as control. Each repair specimen was sectioned into two; one group was repaired using the conventional repair method (Group 1). Two groups had an additional transverse cavity (2x3.5x21.5 mm) prepared prior to the repair; one repaired with (Group 2) and one without glass-fiber reinforcement (Group 3). A three-point flexural bending test according to the ISO 1567:1999 specification8 for denture base polymers was carried out on all groups after 1, 7 and 30 days of water immersion. Statistical analysis was carried out using two-way ANOVA, Kruskal Wallis and post-hoc Mann Whitney tests. Results The highest flexural strength was observed in the control group. Control and conventional repairs group (Group 1) showed reduction in the flexural strength 30 days after water immersion. No significant change in the strength was observed for Groups 2 and 3 where the repair joints were similarly prepared with additional transverse cavity. Conclusion Repaired specimens showed lower flexural strength values than intact heat-curing resin. Cavity preparation had no significant effect on the flexural strength of repair with water immersion. PMID:21308283
Change in muzzle velocity due to freezing and water immersion of .22, long rifle, K.F. cartridges.
Jauhari, M; Chatterjee, S M; Ghosh, P K
1975-01-01
A study of change in muzzle velocity due to freezing and water immersion of .22, long rifle, K. F. cartridges has been presented. A statistical criterion has been formulated to ascertain whether or not a cartridge undergoes a change in muzzle velocity due to a particular treatment. The muzzle velocity data of .22, long rifle, K. F. cartridges, obtained by an electronic timer before and after the various treatments, have been analyzed in the light of this criterion. These cartridges have generally been found to suffer considerable loss in muzzle velocity when immersed in water for three weeks and also when immersed in water for three days and simultaneously cooled to 0 degrees C. The forensic significance of this loss in muzzle velocity has been discussed.
Roberts, Llion A.; Figueiredo, Vandre C.; Egner, Ingrid; Krog, Simone; Aas, Sigve N.; Suzuki, Katsuhiko; Markworth, James F.; Coombes, Jeff S.; Cameron‐Smith, David; Raastad, Truls
2016-01-01
Key points Cold water immersion and active recovery are common post‐exercise recovery treatments. A key assumption about the benefits of cold water immersion is that it reduces inflammation in skeletal muscle. However, no data are available from humans to support this notion.We compared the effects of cold water immersion and active recovery on inflammatory and cellular stress responses in skeletal muscle from exercise‐trained men 2, 24 and 48 h during recovery after acute resistance exercise.Exercise led to the infiltration of inflammatory cells, with increased mRNA expression of pro‐inflammatory cytokines and neurotrophins, and the subcellular translocation of heat shock proteins in muscle. These responses did not differ significantly between cold water immersion and active recovery.Our results suggest that cold water immersion is no more effective than active recovery for minimizing the inflammatory and stress responses in muscle after resistance exercise. Abstract Cold water immersion and active recovery are common post‐exercise recovery treatments. However, little is known about whether these treatments influence inflammation and cellular stress in human skeletal muscle after exercise. We compared the effects of cold water immersion versus active recovery on inflammatory cells, pro‐inflammatory cytokines, neurotrophins and heat shock proteins (HSPs) in skeletal muscle after intense resistance exercise. Nine active men performed unilateral lower‐body resistance exercise on separate days, at least 1 week apart. On one day, they immersed their lower body in cold water (10°C) for 10 min after exercise. On the other day, they cycled at a low intensity for 10 min after exercise. Muscle biopsies were collected from the exercised leg before, 2, 24 and 48 h after exercise in both trials. Exercise increased intramuscular neutrophil and macrophage counts, MAC1 and CD163 mRNA expression (P < 0.05). Exercise also increased IL1β, TNF, IL6, CCL2, CCL4, CXCL2, IL8 and LIF mRNA expression (P < 0.05). As evidence of hyperalgesia, the expression of NGF and GDNF mRNA increased after exercise (P < 0.05). The cytosolic protein content of αB‐crystallin and HSP70 decreased after exercise (P < 0.05). This response was accompanied by increases in the cytoskeletal protein content of αB‐crystallin and the percentage of type II fibres stained for αB‐crystallin. Changes in inflammatory cells, cytokines, neurotrophins and HSPs did not differ significantly between the recovery treatments. These findings indicate that cold water immersion is no more effective than active recovery for reducing inflammation or cellular stress in muscle after a bout of resistance exercise. PMID:27704555
Peake, Jonathan M; Roberts, Llion A; Figueiredo, Vandre C; Egner, Ingrid; Krog, Simone; Aas, Sigve N; Suzuki, Katsuhiko; Markworth, James F; Coombes, Jeff S; Cameron-Smith, David; Raastad, Truls
2017-02-01
Cold water immersion and active recovery are common post-exercise recovery treatments. A key assumption about the benefits of cold water immersion is that it reduces inflammation in skeletal muscle. However, no data are available from humans to support this notion. We compared the effects of cold water immersion and active recovery on inflammatory and cellular stress responses in skeletal muscle from exercise-trained men 2, 24 and 48 h during recovery after acute resistance exercise. Exercise led to the infiltration of inflammatory cells, with increased mRNA expression of pro-inflammatory cytokines and neurotrophins, and the subcellular translocation of heat shock proteins in muscle. These responses did not differ significantly between cold water immersion and active recovery. Our results suggest that cold water immersion is no more effective than active recovery for minimizing the inflammatory and stress responses in muscle after resistance exercise. Cold water immersion and active recovery are common post-exercise recovery treatments. However, little is known about whether these treatments influence inflammation and cellular stress in human skeletal muscle after exercise. We compared the effects of cold water immersion versus active recovery on inflammatory cells, pro-inflammatory cytokines, neurotrophins and heat shock proteins (HSPs) in skeletal muscle after intense resistance exercise. Nine active men performed unilateral lower-body resistance exercise on separate days, at least 1 week apart. On one day, they immersed their lower body in cold water (10°C) for 10 min after exercise. On the other day, they cycled at a low intensity for 10 min after exercise. Muscle biopsies were collected from the exercised leg before, 2, 24 and 48 h after exercise in both trials. Exercise increased intramuscular neutrophil and macrophage counts, MAC1 and CD163 mRNA expression (P < 0.05). Exercise also increased IL1β, TNF, IL6, CCL2, CCL4, CXCL2, IL8 and LIF mRNA expression (P < 0.05). As evidence of hyperalgesia, the expression of NGF and GDNF mRNA increased after exercise (P < 0.05). The cytosolic protein content of αB-crystallin and HSP70 decreased after exercise (P < 0.05). This response was accompanied by increases in the cytoskeletal protein content of αB-crystallin and the percentage of type II fibres stained for αB-crystallin. Changes in inflammatory cells, cytokines, neurotrophins and HSPs did not differ significantly between the recovery treatments. These findings indicate that cold water immersion is no more effective than active recovery for reducing inflammation or cellular stress in muscle after a bout of resistance exercise. © 2016 The Authors. The Journal of Physiology © 2016 The Physiological Society.
Code of Federal Regulations, 2010 CFR
2010-01-01
... dipping it in a solution of 0.0625 percent tannic acid, followed by immersion in a water bath, then... tannic acid for 1 minute followed by immersion in a water bath, then immersing it for 1 minute in a... establishment: Crude carbolic acid; cresylic disinfectant; a formula consisting of 1 part FD&C green No. 3...
Code of Federal Regulations, 2011 CFR
2011-01-01
... dipping it in a solution of 0.0625 percent tannic acid, followed by immersion in a water bath, then... tannic acid for 1 minute followed by immersion in a water bath, then immersing it for 1 minute in a... establishment: Crude carbolic acid; cresylic disinfectant; a formula consisting of 1 part FD&C green No. 3...
Suppression of ADH during water immersion in normal man. [antidiuretic hormone
NASA Technical Reports Server (NTRS)
Epstein, M.; Pins, D. S.; Miller, M.
1975-01-01
A study was undertaken to ascertain whether diuresis induced by immersion is medicated by an inhibition of ADH. Immersion resulted in a progressive decrease in ADH excretion from 80.1 + or - 7 (SEM) to 37.3 + or - 6.3 microU/min (P less than 0.025). Cessation of immersion was associated with a marked increase in ADH from 37.3 + or - 6.3 microU/min to 176.6 + or - 72.6 microU/min during the recovery hour (P less than 0.05). Concomitant with these changes, urine osmolality decreased significantly beginning as early as the initial hour of immersion from 1044 + or - 36 to 542 + or - 66 mosmol/kg H2O during the final hour of immersion (P less than 0.001). These findings are consistent with the earlier suggestion that suppression of ADH release contributes to enhanced free water clearance in hydrated subjects undergoing immersion.
Impact of bleaching agents on water sorption and solubility of resin luting cements.
Torabi Ardakani, Mahshid; Atashkar, Berivan; Bagheri, Rafat; Burrow, Michael F
2017-08-01
The aim of the present study was to evaluate the effect of distilled water and home and office bleaching agents on the sorption and solubility of resin luting cements. A total of 18 disc-shaped specimens were prepared from each of four resin cements: G-CEM LinkAce, Panavia F, Rely X Unicem, and seT. Specimens were cured according to the manufacturers' instructions and randomly divided into three groups of six, where they were treated with either an office or home bleaching agent or immersed in distilled water (control). Water sorption and solubility were measured by weighing the specimens before and after immersion and desiccation. Data were analyzed using Pearson correlation coefficient, two-way analysis of variance (ANOVA) and Tukey's test. There was a significant, positive correlation between sorption and solubility. Two-way anova showed significant differences among all resin cements tested for either sorption or solubility. Water sorption and solubility of all cements were affected significantly by office bleaching, and even more by home bleaching agents. Sorption and solubility behavior of the studied cements were highly correlated and significantly affected by applying either office or home bleaching agents; seT showed the highest sorption and solubility, whereas Rely X Unicem revealed the lowest. © 2016 John Wiley & Sons Australia, Ltd.
Arocha, Mariana A; Basilio, Juan; Llopis, Jaume; Di Bella, Enrico; Roig, Miguel; Ardu, Stefano; Mayoral, Juan R
2014-07-01
The aim of this study was to determine, by using a spectrophotometer device, the colour stainability of two indirect CAD/CAM processed composites in comparison with two conventionally laboratory-processed composites after being immersed 4 weeks in staining solutions such as coffee, black tea and red wine, using distilled water as control group. Two indirect CAD/CAM composites (Lava Ultimate and Paradigm MZ100) and two conventionally laboratory-processed composites (SR Adoro and Premise Indirect) of shade A2 were selected (160 disc samples). Colour stainability was measured after 4 weeks of immersion in three staining solutions (black tea, coffee, red wine) and distilled water. Specimen's colour was measured each week by means of a spectrophotometer (CIE L*a*b* system). Statistical analysis was carried out performing repeated ANOVA measurements and Tukey's HSD test to evaluate differences in ΔE00 measurements between groups; the interactions among composites, staining solutions and time duration were also evaluated. All materials showed significant discoloration (p<0.01) when compared to control group. The highest ΔE00 observed was with red wine, whereas black tea showed the lowest one. Indirect laboratory-processed resin composites showed the highest colour stability compared with CAD/CAM resin blocks. CAD/CAM processed composites immersed in staining solutions showed lower colour stability when compared to conventionally laboratory-processed resin composites. The demand for CAD/CAM restorations has been increasing; however, colour stainability for such material has been insufficiently studied. Moreover, this has not been performed comparing CAD/CAM processed composites versus laboratory-processed indirect composites by immersing in staining solutions for long immersion periods. Copyright © 2014 Elsevier Ltd. All rights reserved.
Code of Federal Regulations, 2014 CFR
2014-10-01
... designed to prevent shock upon entering cold water and lessen the effect of hypothermia (extreme body heat loss due to immersion in cold water). Immersion suits approved under this subpart will meet the...
Code of Federal Regulations, 2010 CFR
2010-10-01
... designed to prevent shock upon entering cold water and lessen the effect of hypothermia (extreme body heat loss due to immersion in cold water). Immersion suits approved under this subpart will meet the...
Stress corrosion cracking evaluation of martensitic precipitation hardening stainless steels
NASA Technical Reports Server (NTRS)
Humphries, T. S.; Nelson, E. E.
1980-01-01
The resistance of the martensitic precipitation hardening stainless steels PH13-8Mo, 15-5PH, and 17-4PH to stress corrosion cracking was investigated. Round tensile and c-ring type specimens taken from several heats of the three alloys were stressed up to 100 percent of their yield strengths and exposed to alternate immersion in salt water, to salt spray, and to a seacoast environment. The results indicate that 15-5PH is highly resistant to stress corrosion cracking in conditions H1000 and H1050 and is moderately resistant in condition H900. The stress corrosion cracking resistance of PH13-8Mo and 17-4PH stainless steels in conditions H1000 and H1050 was sensitive to mill heats and ranged from low to high among the several heats included in the tests. Based on a comparison with data from seacoast environmental tests, it is apparent that alternate immersion in 3.5 percent salt water is not a suitable medium for accelerated stress corrosion testing of these pH stainless steels.
Warm immersion recovery test in assessment of diabetic neuropathy--a proof of concept study.
Bharara, Manish; Viswanathan, Vijay; Cobb, Jonathan E
2008-10-01
The aim of this article was to present results of warm immersion recovery test in the diabetic foot with neuropathy using a liquid crystal-based contact thermography system. It is intended to provide a 'proof of concept' for promoting the role of supplementary thermal assessment techniques and evidence-based diagnosis of diabetic neuropathy. A total of 81 subjects from the outpatient department of MV Hospital for Diabetes, India, were assessed using a liquid crystal thermography system. Each subject was assigned to one of three study groups, that is diabetic neuropathy, diabetic non neuropathy and non diabetic healthy. The room temperature and humidity were consistently maintained at 24 degrees C and less than 50%, respectively, with air conditioning. The right foot for each subject was located on the measurement platform after warm immersion in water at 37 degrees C. Whole-field thermal images of the plantar foot were recorded for 10 minutes. Local measurements at the most prevalent sites of ulceration, that is metatarsal heads, great toe and heel, show highest temperature deficit after recovery for diabetic neuropathy group. The findings of the current study support the ones of a previous study by the authors, which used cold immersion recovery test for the neuropathic assessment of the diabetic foot. A temperature deficit between the recovery and the baseline temperature for the neuropathic group suggests degeneration of thermoreceptors. Thermal stimulus tests can be useful to validate the nutritional deficits' (during plantar loading and thermal stimulus) contribution in foot ulceration.
Committee Opinion No. 679: Immersion in Water During Labor and Delivery.
2016-11-01
Immersion in water during labor or delivery has been popularized over the past several decades. The prevalence of this practice in the United States is uncertain because it has not been studied in births outside of the home and birth centers, and the data are not recorded on birth certificates. Among randomized controlled trials included in a 2009 Cochrane systematic review that addressed immersion in the first stage of labor, results were inconsistent with regard to maternal benefits. Neither the Cochrane systematic review nor any individual trials included in that review reported any benefit to the newborn from maternal immersion during labor or delivery. Immersion in water during the first stage of labor may be associated with shorter labor and decreased use of spinal and epidural analgesia and may be offered to healthy women with uncomplicated pregnancies between 37 0/7 weeks and 41 6/7 weeks of gestation. There are insufficient data on which to draw conclusions regarding the relative benefits and risks of immersion in water during the second stage of labor and delivery. Therefore, until such data are available, it is the recommendation of the American College of Obstetricians and Gynecologists that birth occur on land, not in water. A woman who requests to give birth while submerged in water should be informed that the maternal and perinatal benefits and risks of this choice have not been studied sufficiently to either support or discourage her request. Facilities that plan to offer immersion during labor and delivery need to establish rigorous protocols for candidate selection; maintenance and cleaning of tubs and pools; infection control procedures, including standard precautions and personal protective equipment for health care personnel; monitoring of women and fetuses at appropriate intervals while immersed; and moving women from tubs if urgent maternal or fetal concerns or complications develop.
Benfield, Rebecca D.; Hortobágyi, Tibor; Tanner, Charles J.; Swanson, Melvin; Heitkemper, Margaret M.; Newton, Edward R.
2013-01-01
Background Hydrotherapy (immersion, or bathing) is used worldwide to promote relaxation and decrease parturient anxiety and pain in labor, but the psychophysiological effects of this intervention remain obscure. Design A pre-test post-test design with repeated measures was used to examine the effects of hydrotherapy on maternal anxiety and pain, neuroendocrine responses, plasma volume shift and uterine contractions during labor. Correlations among variables were examined at three time points (pre-immersion and twice during hydrotherapy). Methods Eleven term women (mean age 24.5 years) in spontaneous labor were immersed to the xiphoid in 37°C water for 1 hr. Blood samples and measures of anxiety and pain were obtained under dry baseline conditions and repeated at 15 and 45 min of hydrotherapy. Uterine contractions were monitored telemetrically. Results Hydrotherapy was associated with decreases in anxiety, vasopressin and oxytocin levels at 15 and 45 min (all p < .05). There were no significant differences between pre-immersion and immersion pain or cortisol levels. Pain decreased more for women with high baseline pain than for women with low baseline levels at 15 and 45 min. Cortisol levels decreased twice as much at 15 min of hydrotherapy for women with high baseline pain as for those with low baseline pain. Beta-endorphin levels increased at 15 min but did not differ between baseline and 45 min. During immersion, uterine-contraction frequency decreased. A positive plasma volume shift at 15 min was correlated with contraction duration. Conclusions Hydrotherapy during labor affects neuroendocrine responses that modify psychophysiological processes. PMID:20453024
Heat transfer coefficient: Medivance Arctic Sun Temperature Management System vs. water immersion.
English, M J; Hemmerling, T M
2008-07-01
To improve heat transfer, the Medivance Arctic Sun Temperature Management System (Medivance, Inc., Louisville, CO, USA) features an adhesive, water-conditioned, highly conductive hydrogel pad for intimate skin contact. This study measured and compared the heat transfer coefficient (h), i.e. heat transfer efficiency, of this pad (hPAD), in a heated model and in nine volunteers' thighs; and of 10 degrees C water (hWATER) in 33 head-out immersions by 11 volunteers. Volunteer studies had ethical approval and written informed consent. Calibrated heat flux transducers measured heat flux (W m-2). Temperature gradient (DeltaT) was measured between skin and pad or water temperatures. Temperature gradient was changed through the pad's water temperature controller or by skin cooling on immersion. The heat transfer coefficient is the slope of W m-2/DeltaT: its unit is W m-2 degrees C-1. Average with (95% CI) was: model, hPAD = 110.4 (107.8-113.1), R2 = 0.99, n = 45; volunteers, hPAD = 109.8 (95.5-124.1), R2 = 0.83, n = 51; and water immersion, hWATER = 107.1 (98.1-116), R2 = 0.86, n = 94. The heat transfer coefficient for the pad was the same in the model and volunteers, and equivalent to hWATER. Therefore, for the same DeltaT and heat transfer area, the Arctic Sun's heat transfer rate would equal water immersion. This has important implications for body cooling/rewarming rates.
33 CFR 150.518 - What are the inspection requirements for work vests and immersion suits?
Code of Federal Regulations, 2013 CFR
2013-07-01
... requirements for work vests and immersion suits? 150.518 Section 150.518 Navigation and Navigable Waters COAST... vests and immersion suits? (a) All work vests and immersion suits must be inspected by the owner or... a work vest or immersion suit is inspected and is in serviceable condition, then it may remain in...
33 CFR 150.518 - What are the inspection requirements for work vests and immersion suits?
Code of Federal Regulations, 2012 CFR
2012-07-01
... requirements for work vests and immersion suits? 150.518 Section 150.518 Navigation and Navigable Waters COAST... vests and immersion suits? (a) All work vests and immersion suits must be inspected by the owner or... a work vest or immersion suit is inspected and is in serviceable condition, then it may remain in...
33 CFR 150.518 - What are the inspection requirements for work vests and immersion suits?
Code of Federal Regulations, 2010 CFR
2010-07-01
... requirements for work vests and immersion suits? 150.518 Section 150.518 Navigation and Navigable Waters COAST... vests and immersion suits? (a) All work vests and immersion suits must be inspected by the owner or... a work vest or immersion suit is inspected and is in serviceable condition, then it may remain in...
33 CFR 150.518 - What are the inspection requirements for work vests and immersion suits?
Code of Federal Regulations, 2011 CFR
2011-07-01
... requirements for work vests and immersion suits? 150.518 Section 150.518 Navigation and Navigable Waters COAST... vests and immersion suits? (a) All work vests and immersion suits must be inspected by the owner or... a work vest or immersion suit is inspected and is in serviceable condition, then it may remain in...
33 CFR 150.518 - What are the inspection requirements for work vests and immersion suits?
Code of Federal Regulations, 2014 CFR
2014-07-01
... requirements for work vests and immersion suits? 150.518 Section 150.518 Navigation and Navigable Waters COAST... vests and immersion suits? (a) All work vests and immersion suits must be inspected by the owner or... a work vest or immersion suit is inspected and is in serviceable condition, then it may remain in...
Bural, Canan; Aktaş, Esin; Deniz, Günnur; Ünlüçerçi, Yeşim; Kızılcan, Nilgün; Bayraktar, Gülsen
2011-11-01
This study evaluated the effect of post-polymerization heat-treatments on degree of conversion (DC), residual methyl methacrylate concentration (MMA(r)) and in vitro cytotoxicity of autopolymerizing acrylic repair resin. A total of 336 specimens were prepared by bench- and hydroflask-curing and subjected to post-polymerization heat-treatments: a) water immersion at 60°C for 30 min, b) microwaving at 500 W for 3 min, c) combined use of water immersion and microwaving d) no treatment (as control). Specimens were eluted in cell culture medium for 1, 2, 5 and 7 days. DC and MMA(r) in eluates were measured by FTIR spectrometry and HPLC, respectively. In vitro cytotoxicity of eluates on L-929 fibroblasts was determined by XTT assay. Data were statistically analyzed with Dunn's multiple comparison and Pearson correlation tests (p≤0.05). DC was highest (99.9%) in bench- and hydroflask-cured groups which were subjected to water immersion. At all elution periods, MMA(r) was detected in eluates of all treatment groups and were higher in bench-cured groups than hydro-flask cured groups. Cell proliferation values indicated slightly cytotoxic effect throughout 7 days; regardless of the curing method or post-polymerization treatment. The correlation between MMA(r) and cell proliferation was negative after elution of 1, 2, 5 days and was only statistically significant (p<0.05) at 5 days. At elution of 7 days, the correlation was positive with no significance. Post-polymerization heat-treatment of autopolymerizing acrylic repair resin by immersion in water at 60°C for 30 min is clinically recommended to improve the DC while reducing the leaching residual MMA. Copyright © 2011 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Water Immersion Affects Episodic Memory and Postural Control in Healthy Older Adults.
Bressel, Eadric; Louder, Talin J; Raikes, Adam C; Alphonsa, Sushma; Kyvelidou, Anastasia
2018-05-04
Previous research has reported that younger adults make fewer cognitive errors on an auditory vigilance task while in chest-deep water compared with on land. The purpose of this study was to extend this previous work to include older adults and to examine the effect of environment (water vs land) on linear and nonlinear measures of postural control under single- and dual-task conditions. Twenty-one older adult participants (age = 71.6 ± 8.34 years) performed a cognitive (auditory vigilance) and motor (standing balance) task separately and simultaneously on land and in chest-deep water. Listening errors (n = count) from the auditory vigilance test and sample entropy (SampEn), center of pressure area, and velocity for the balance test served as dependent measures. Environment (land vs water) and task (single vs dual) comparisons were made with a Wilcoxon matched-pair test. Listening errors were 111% greater during land than during water environments (single-task = 4.0 ± 3.5 vs 1.9 ± 1.7; P = .03). Conversely, SampEn values were 100% greater during water than during land environments (single-task = 0.04 ± 0.01 vs 0.02 ± 0.01; P < .001). Center of pressure area and velocity followed a similar trend to SampEn with respect to environment differences, and none of the measures were different between single- and dual-task conditions (P > .05). The findings of this study expand current support for the potential use of partial aquatic immersion as a viable method for challenging both cognitive and motor abilities in older adults.
Optimized water vapor permeability of sodium alginate films using response surface methodology
NASA Astrophysics Data System (ADS)
Zhang, Qing; Xu, Jiachao; Gao, Xin; Fu, Xiaoting
2013-11-01
The water vapor permeability (WVP) of films is important when developing pharmaceutical applications. Films are frequently used as coatings, and as such directly influence the quality of the medicine. The optimization of processing conditions for sodium alginate films was investigated using response surface methodology. Single-factor tests and Box-Behnken experimental design were employed. WVP was selected as the response variable, and the operating parameters for the single-factor tests were sodium alginate concentration, carboxymethyl cellulose (CMC) concentration and CaCl2 solution immersion time. The coefficient of determination ( R 2) was 0.97, indicating statistical significance. A minimal WVP of 0.389 8 g·mm/(m2·h·kPa) was achieved under the optimum conditions. These were found to be a sodium alginate concentration, CMC concentration and CaCl2 solution immersion time at 8.04%, 0.13%, and 12 min, respectively. This provides a reference for potential applications in manufacturing film-coated hard capsule shells.
Immersion lithography: its history, current status and future prospects
NASA Astrophysics Data System (ADS)
Owa, Soichi; Nagasaka, Hiroyuki
2008-11-01
Since the 1980's, immersion exposure has been proposed several times. At the end of 1990's, however, these concepts were almost forgotten because other technologies, such as electron beam projection, EUVL, and 157 nm were believed to be more promising than immersion exposures. The current work in immersion lithography started in 2001 with the report of Switkes and Rothschild. Although their first proposal was at 157 nm wavelength, their report in the following year on 193 nm immersion with purified water turned out to be the turning point for the introduction of water-based 193 nm immersion lithography. In February, 2003, positive feasibility study results of 193 nm immersion were presented at the SPIE microlithography conference. Since then, the development of 193 nm immersion exposure tools accelerated. Currently (year 2008), multiple hyper NA (NA>1.0) scanners are generating mass production 45 nm half pitch devices in semiconductor manufacturing factories. As a future extension, high index immersion was studied over the past few years, but material development lagged more than expected, which resulted in the cancellation of high index immersion plans at scanner makers. Instead, double patterning, double dipole exposure, and customized illuminations techniques are expected as techniques to extend immersion for the 32 nm node and beyond.
Prolonged whole-body cold water immersion: fluid and ion shifts.
Deuster, P A; Smith, D J; Smoak, B L; Montgomery, L C; Singh, A; Doubt, T J
1989-01-01
To characterize fluid and ion shifts during prolonged whole-body immersion, 16 divers wearing dry suits completed four whole-body immersions in 5 degrees C water during each of two 5-day air saturation dives at 6.1 msw. One immersion was conducted at 1000 (AM) and one at 2200 (PM) so that diurnal variations could be evaluated. Fifty-four hours separated the immersions, which lasted up to 6 h; 9 days separated each air saturation dive. Blood was collected before and after immersion; urine was collected for 12 h before, during, and after immersion for a total of 24 h. Plasma volume decreased significantly and to the same extent (approximately 17%) during both AM and PM immersions. Urine flow increased by 236.1 +/- 38.7 and 296.3 +/- 52.0%, urinary excretion of Na increased by 290.4 +/- 89.0 and 329.5 +/- 77.0%, K by 245.0 +/- 73.4 and 215.5 +/- 44.6%, Ca by 211.0 +/- 31.4 and 241.1 +/- 50.4%, Mg by 201.4 +/- 45.9 and 165.3 +/- 287%, and Zn by 427.8 +/- 93.7 and 301.9 +/- 75.4% during AM and PM immersions, respectively, compared with preimmersion. Urine flow and K excretion were significantly higher during the AM than PM. In summary, when subjects are immersed in cold water for prolonged periods, combined with a slow rate of body cooling afforded by thermal protection and enforced intermittent exercise, there is diuresis, decreased plasma volume, and increased excretions of Na, K, Ca, Mg, and Zn.
Performance Test on Polymer Waste Form - 12137
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Se Yup
Polymer solidification was attempted to produce stable waste form for the boric acid concentrates and the dewatered spent resins. The polymer mixture was directly injected into the mold or drum which was packed with the boric acid concentrates and the dewatered spent resins, respectively. The waste form was produced by entirely curing the polymer mixture. A series of performance tests was conducted including compressive strength test, water immersion test, leach test, thermal stability test, irradiation stability test and biodegradation stability test for the polymer waste forms. From the results of the performance tests for the polymer waste forms, it ismore » believed that the polymer waste form is very stable and can satisfy the acceptance criteria for permanent disposal. At present, performance tests with full scale polymer waste forms are being carried out in order to obtain qualification certificate by the regulatory institute in Korea. Polymer waste forms were prepared with the surrogate of boric acid concentrates and the surrogate of spent ion exchange resins respectively. Waste forms were also made in lab scale and in full scale. Lab. scale waste forms were directly subjected to a series of the performance tests. In the case of full scale waste form, the test specimens for the performance test were taken from a part of waste form by coring. A series of performance tests was conducted including compressive strength test, thermal stability test, irradiation stability test and biodegradation stability test, water immersion test, leach test, and free standing water for the polymer waste forms. In addition, a fire resistance test was performed on the waste forms by the requirement of the regulatory institute in Korea. Every polymer waste forms containing the boric acid concentrates and the spent ion exchange resins had exhibited excellent structural integrity of more than 27.58 MPa (4,000 psi) of compressive strength. On thermal stability testing, biodegradation testing and water immersion testing, no degradation was observed in the waste forms. Also, by measuring the compressive strength after these tests, it was confirmed that the structural integrity was still retained. A leach test was performed by using non radioactive cobalt, cesium and strontium. The leaching of cobalt, cesium and strontium from the polymer waste forms was very low. Also, the polymer waste forms were found to possess adequate fire resistance. From the results of the performance tests, it is believed that the polymer waste form is very stable and can satisfy the acceptance criteria for permanent disposal. At present, Performance tests with full scale polymer waste forms are on-going in order to obtain qualification certificate by the regulatory institute in Korea. (authors)« less
NASA Astrophysics Data System (ADS)
Sugiman, Gozali, M. Hulaifi; Setyawan, Paryanto Dwi
2016-03-01
Glass fiber reinforced polymer has been widely used in chemical industry and transportation due to lightweight and cost effective manufacturing. However due to the ability to absorb water from the environment, the durability issue is of interest for up to days. This paper investigated the water uptake and the effect of absorbed water on the tensile properties and the translaminar fracture toughness of glass fiber reinforced unsaturated polyester composites (GFRP) aged in distilled and salt water up to 30 days at a temperature of 50°C. It has been shown that GFRP absorbed more water in distilled water than in salt water. In distilled water, the tensile strength of GFRP tends to decrease steeply at 7 days and then slightly recovered for further immersion time. In salt water, the tensile strength tends to decrease continually up to 30 days immersion. The translaminar fracture toughness of GFRP aged in both distilled and salt-water shows the similar behavior. The translaminar fracture toughness increases after 7 days immersion and then tends to decrease beyond that immersion time. In the existence of ionics content in salt water, it causes more detrimental effect on the mechanical properties of fiberglass/unsaturated polyester composites compared to that of distilled water.
Loading forces in shallow water running in two levels of immersion.
Haupenthal, Alessandro; Ruschel, Caroline; Hubert, Marcel; de Brito Fontana, Heiliane; Roesler, Helio
2010-07-01
To analyse the vertical and anteroposterior components of the ground reaction force during shallow water running at 2 levels of immersion. Twenty-two healthy adults with no gait disorders, who were familiar with aquatic exercises. Subjects performed 6 trials of water running at a self-selected speed in chest and hip immersion. Force data were collected through an underwater force plate and running speed was measured with a photocell timing light system. Analysis of covariance was used for data analysis. Vertical forces corresponded to 0.80 and 0.98 times the subject's body weight at the chest and hip level, respectively. Anteroposterior forces corresponded to 0.26 and 0.31 times the subject's body weight at the chest and hip level, respectively. As the water level decreased the subjects ran faster. No significant differences were found for the force values between the immersions, probably due to variability in speed, which was self-selected. When thinking about load values in water running professionals should consider not only the immersion level, but also the speed, as it can affect the force components, mainly the anteroposterior one. Quantitative data on this subject could help professionals to conduct safer aqua-tic rehabilitation and physical conditioning protocols.
Neppelenbroek, Karin Hermana; Kurokawa, Luciana Ayumi; Procópio, Andréa Lemos Falcão; Pegoraro, Thiago Amadei; Hotta, Juliana; Mello Lima, Jozely Francisca; Urban, Vanessa Migliorini
2015-01-01
To evaluate the effect of successive cycles of disinfection in different denture cleansers on the surface roughness and the Vickers hardness of two layers of acrylic resin (base-BL and enamel-EL) of two commercial cross-linked artificial teeth. The occlusal surfaces of 60 acrylic resin denture posterior teeth (Trilux-TLX and SR Orthosit PE-SRO) embedded in autopolymerizing acrylic resin were ground fat with 1200-grit silicon carbide paper. Specimens were stored in distilled water at 37°C and then submitted to the microhardness (VHN) and roughness (μm) tests. Specimens were stored in distilled water at 37°C for 90 days and submitted to 720 disinfection cycles in sodium hypochlorite at 0.5%, 30% vinegar solution or distilled water (control). Afterward, micro-hardness and roughness tests were again performed. Data were analyzed using two-way ANOVA and Tukey's test (α=0.05). Hypochlorite immersion decreased the hardness of BL and EL of SRO teeth, with an average reduction of 10.11% (p<0.008). TLX teeth demonstrated a hardness reduction of 28.96% of both layers for all solutions including water (p<0.0000). The roughness of both teeth was not affected by denture cleansers (p>0.37). Hypochlorite promoted deleterious effects on the hardness of both layers of the artificial teeth tested. Immersion in vinegar and water also resulted in reduction of hardness of TLX teeth. The surface hardness of the different layers of cross-linked artificial teeth can be altered by daily disinfection in denture cleansers commonly indicated for removable dentures.
Reinhardt, Keith; Smith, William K
2008-11-01
The red spruce-Fraser fir ecosystem [Picea rubens Sarg.-Abies fraseri (Pursh) Poir.] of the southern Appalachian mountains, USA, is a temperate zone cloud forest immersed in clouds for 30-40% of a typical summer day, and experiencing immersion on about 65% of all days annually. We compared the microclimate, photosynthetic gas exchange, and water relations of Fraser fir trees in open areas during cloud-immersed, low-cloud, or sunny periods. In contrast to sunny periods, cloud immersion reduced instantaneous sunlight irradiance by 10-50%, and midday atmospheric vapor pressure deficit (VPD) was 85% lower. Needle surfaces were wet for up to 16 h per day during cloud-immersed days compared to <1 h for clear days. Shoot-level light-saturated photosynthesis (A (sat)) on both cloud-immersed (16.0 micromol m(-2) s(-1)) and low-cloud (17.9 micromol m(-2) s(-1)) days was greater than A (sat) on sunny days (14.4 micromol m(-2) s(-1)). Daily mean A was lowest on cloud-immersed days due to reduced sunlight levels, while leaf conductance (g) was significantly higher, with a mean value of 0.30 mol m(-2) s(-1). These g values were greater than commonly reported for conifer tree species with needle-like leaves, and declined exponentially with increasing leaf-to-air VPD. Daily mean transpiration (E) on immersed days was 43 and 20% lower compared to sunny and low-cloud days, respectively. As a result, daily mean water use efficiency (A/E) was lowest on cloud-immersed days due to light limitation of A, and high humidity resulted in greater uncoupling of A from g. Thus, substantial differences in photosynthetic CO2 uptake, and corresponding water relations, were strongly associated with cloud conditions that occur over substantial periods of the summer growth season.
Rizzetti, Danize Aparecida; Quadros, Janayna Rodembuch Borba; Ribeiro, Bruna Esmerio; Callegaro, Letícia; Veppo, Aline Arebalo; Wiggers, Giulia Alessandra; Peçanha, Franck Maciel
2017-01-01
ABSTRACT Objective: To determine whether different levels of CPAP improve the lung volumes and capacities of healthy subjects immersed in water. Methods: This was a randomized clinical trial, conducted between April and June of 2016, involving healthy female volunteers who were using oral contraceptives. Three 20-min immersion protocols were applied: control (no CPAP); CPAP5 (CPAP at 5 cmH2O); and CPAP10 (CPAP at 10 cmH2O). We evaluated HR, SpO2, FVC, FEV1, the FEV1/FVC ratio, peak expiratory flow rate (PEFR), and FEF25-75%) at three time points: pre-immersion; 10 min after immersion; and 10 min after the end of each protocol. Results: We evaluated 13 healthy volunteers. The CPAP10 protocol reversed the restrictive pattern of lung function induced by immersion in water, maintaining pulmonary volumes and capacities for a longer period than did the CPAP5 protocol. Conclusions: When the hemodynamic change causing a persistent lung disorder, only the application of higher positive pressures is effective in maintaining long-term improvements in the pulmonary profile. PMID:29340488
Rizzetti, Danize Aparecida; Quadros, Janayna Rodembuch Borba; Ribeiro, Bruna Esmerio; Callegaro, Letícia; Veppo, Aline Arebalo; Wiggers, Giulia Alessandra; Peçanha, Franck Maciel
2017-01-01
To determine whether different levels of CPAP improve the lung volumes and capacities of healthy subjects immersed in water. This was a randomized clinical trial, conducted between April and June of 2016, involving healthy female volunteers who were using oral contraceptives. Three 20-min immersion protocols were applied: control (no CPAP); CPAP5 (CPAP at 5 cmH2O); and CPAP10 (CPAP at 10 cmH2O). We evaluated HR, SpO2, FVC, FEV1, the FEV1/FVC ratio, peak expiratory flow rate (PEFR), and FEF25-75%) at three time points: pre-immersion; 10 min after immersion; and 10 min after the end of each protocol. We evaluated 13 healthy volunteers. The CPAP10 protocol reversed the restrictive pattern of lung function induced by immersion in water, maintaining pulmonary volumes and capacities for a longer period than did the CPAP5 protocol. When the hemodynamic change causing a persistent lung disorder, only the application of higher positive pressures is effective in maintaining long-term improvements in the pulmonary profile.
NASA Technical Reports Server (NTRS)
Wingard, Charles D.
2003-01-01
In the International Space Station (ISS), astronauts will convert urine into potable water with the Urine Processor Assembly (UPA) by a distillation process. The urine is pre-treated, containing flush water and stabilizers. About 2.5% solids in the urine are concentrated up to 16% brine through distillation. Dynamic mechanical analysis (DMA) in the stress relaxation mode was primarily used to test 15 polymeric UPA materials for compatibility with the pre-treated and brine solutions. There were concerns that chromium trioxide (CrO3), a stabilizer not in the original pre-treat formulation for similar compatibility testing in 2000, could have an adverse effect on these polymers. DMA testing is partially complete for polymeric material samples immersed in the two solutions at room temperature for as long as 200 days. By comparing each material (conditioned and virgin), the stress relaxation modulus (E) was determined for short-term use and predicted for as long as a 10-year use in space. Such a delta E showed a decrease of as much as 79% for a Nylon material, but an increase as much as 454% for a polysulfone material, with increasing immersion time.
Severin, Anna C; Burkett, Brendan J; McKean, Mark R; Wiegand, Aaron N; Sayers, Mark G L
2017-01-01
The presence of pain during movement typically results in changes in technique. However, the physical properties of water, such as flotation, means that water-based exercise may not only reduce compensatory movement patterns but also allow pain sufferers to complete exercises that they are unable to perform on land. The purpose of this study was to assess bilateral kinematics during double-leg squats and single-leg squats on land and in water in individuals with unilateral anterior knee pain. A secondary aim was to quantify bilateral asymmetry in both environments in affected and unaffected individuals using a symmetry index. Twenty individuals with unilateral knee pain and twenty healthy, matched controls performed body weight double- and single-leg squats in both environments while inertial sensors (100 Hz) recorded trunk and lower body kinematics. Repeated-measures statistics tested for environmental effects on movement depths and peak angles within the anterior knee pain group. Differences in their inter-limb symmetry in each environments was compared to the control group using analysis of variance tests. Water immersion allowed for greater movement depths during both exercises (double-leg squat: +7 cm, p = 0.032, single-leg squat: +9 cm, p = 0.002) for the knee pain group. The double-leg squat was symmetrical on land but water immersion revealed asymmetries in the lower body frontal plane movements. The single-leg squat revealed decreased hip flexion and frontal plane shank motions on the affected limb in both environments. Water immersion also affected the degree of lower limb asymmetry in both groups, with differences also showing between groups. Individuals with anterior knee pain achieved increased squat depth during both exercises whilst in water. Kinematic differences between the affected and unaffected limbs were often increased in water. Individuals with unilateral anterior knee pain appear to utilise different kinematics in the affected and unaffected limb in both environments.
Water immersion in neonatal bereavement photography.
Duffey, Heather
2014-01-01
Water immersion in neonatal bereavement photography is a new technique intended to enhance the quality of the photographs provided to families following their loss. Water immersion appears to be most helpful following a second trimester fetal demise. This technique can be used by nurses, professional photographers and others in addition to more traditional neonatal bereavement photography. It does not require special skills or equipment and can be implemented in virtually any perinatal setting. The enhanced quality of photographs produced with this method can potentially provide a source of comfort to grieving families. © 2014 AWHONN.
NASA Technical Reports Server (NTRS)
Epstein, M.
1975-01-01
The effects of water immersion on acid-base homeostasis were investigated under carefully controlled conditions. Studies of renal acidification were carried out on seven healthy male subjects, each consuming a diet containing 150 meq sodium and 100 meq potassium. Control and immersion studies were carried out on each subject on the fourth and sixth days, respectively, of dietary equilibration, by which time all subjects had achieved sodium balance. The experimental protocols on study days were similar (except for the amount of water administered).
Code of Federal Regulations, 2010 CFR
2010-01-01
... specified temperature for a specific time period to kill targeted pests. Vapor heat. Heated air saturated with water vapor and used to raise the temperature of a commodity to a required point for a specific... products. Hot water immersion dip. Complete immersion of a commodity in heated water to raise the...
Ground Reaction Force and Cadence during Stationary Running Sprint in Water and on Land.
Fontana, H de Brito; Ruschel, C; Haupenthal, A; Hubert, M; Roesler, H
2015-06-01
This study was aimed at analyzing the cadence (Cadmax) and the peak vertical ground reaction force (Fymax) during stationary running sprint on dry land and at hip and chest level of water immersion. We hypothesized that both Fymax and Cadmax depend on the level of immersion and that differences in Cadmax between immersions do not affect Fymax during stationary sprint. 32 subjects performed the exercise at maximum cadence at each immersion level and data were collected with force plates. The results show that Cadmax and Fymax decrease 17 and 58% from dry land to chest immersion respectively, with no effect of cadence on Fymax. While previous studies have shown similar neuromuscular responses between aquatic and on land stationary sprint, our results emphasize the differences in Fymax between environments and levels of immersion. Additionally, the characteristics of this exercise permit maximum movement speed in water to be close to the maximum speed on dry land. The valuable combination of reduced risk of orthopedic trauma with similar neuromuscular responses is provided by the stationary sprint exercise in water. The results of this study support the rationale behind the prescription of stationary sprinting in sports training sessions as well as rehabilitation programs. © Georg Thieme Verlag KG Stuttgart · New York.
The effect of aging on the fracture toughness of esthetic restorative materials.
Bagheri, Rafat; Azar, Mohammad R; Tyas, Martin J; Burrow, Michael F
2010-06-01
To compare the fracture toughness (KIc) of tooth-colored restorative materials based on a four-point bending; to assess the effect of distilled water and a resin surface sealant (G-Coat Plus) on the resistance of the materials to fracture. Specimens were prepared from six materials: Quix Fil; Dyract (Dentsply), Freedom (SDI), Fuji VII (GC), Fuji IX (GC); Fuji II LC (GC). Fuji II LC and Fuji IX were tested both with and without applying G-Coat Plus (GC). The specimens were divided into the three groups which were conditioned in distilled water at 37 degrees C for 48 hours, 4 and 8 weeks. The specimens were loaded in a four-point bending test using a universal testing machine. The maximum load to specimen failure was recorded and the fracture toughness calculated. There were significant differences among most of the materials (P < 0.001). Quix Fil had the highest mean KIc value and Fuji VII the lowest. Immersion in distilled water for the resin composite and polyacid-modified resin composites caused a significant decrease in KIc as the time interval increased. For glass-ionomer cements, KIc decreased significantly after 4 weeks, and after 8 weeks immersion slightly increased. G-Coat Plus affected Fuji II LC positively while it had no effect on the Fuji IX.
Cardiac output variations in supine resting subjects during head-out cold water immersion.
Vogelaere, P; Deklunder, G; Lecroart, J
1995-08-01
Five men, aged 31.2 years (SD 2.3), under semi-nude conditions and resting in a dorsal reclining position, were exposed to thermoneutral air for 30 min, followed immediately by a cold water (15 degrees C) immersion for 60 min. Cardiac output was measured using a dual-beam Doppler flow meter. During immersion in cold water, cardiac frequency (fc) showed an initial bradycardia. The lowest values were reached at about 10 min after immersion, 58.3 (SD 2.5) to 48.3 (SD 7.8) beats min-1 (P < 0.05). By the 20th min of exposure, fc had gradually risen to 70.0 beats min-1 (SD 6.6, P < 0.05). This change could be due to the inhibition of the initial vagal reflex by increased catecholamine concentration. Stroke volume (Vs) was significantly increased (P < 0.05) during the whole cold immersion period. Cardiac output, increased from 3.57 (SD 0.50) to 6.26 (SD 1.33) l min-1 (P < 0.05) and its change with time was a function of both Vs and fc. On the other hand, systolic flow acceleration was unchanged during the period of immersion. The changes in the respiratory variables (ventilation, oxygen uptake, carbon dioxide output and respiratory exchange ratio) during immersion showed an initial hyperventilation followed, as immersion proceeded, by a slower metabolic increase due to shivering.
Cardiac output variations in supine resting subjects during head-out cold water immersion
NASA Astrophysics Data System (ADS)
Vogelaere, P.; Deklunder, G.; Lecroart, J.
1995-03-01
Five men, aged 31.2 years (SD 2.3), under semi-nude conditions and resting in a dorsal reclining position, were exposed to thermoneutral air for 30 min, followed immediately by a cold water (15°C) immersion for 60 min. Cardiac output was measured using a dualbeam Doppler flow meter. During immersion in cold water, cardiac frequency ( f c) showed an initial bradycardia. The lowest values were reached at about 10 min after immersion, 58.3 (SD 2.5) to 48.3 (SD 7.8) beats min-1 ( P < 0.05). By the 20th min of exposure, f c had gradually risen to 70.0 beats min-1 (SD 6.6, P < 0.05). This change could be due to the inhibition of the initial vagal reflex by increased catecholamine concentration. Stroke volume ( V s) was significantly increased ( P < 0.05) during the whole cold immersion period. Cardiac output, increased from 3.57 (SD 0.50) to 6.26 (SD 1.33)1 min-1 ( P < 0.05) and its change with time was a function of both V s and f c. On the other hand, systolic flow acceleration was unchanged during the period of immersion. The changes in the respiratory variables (ventilation, oxygen uptake, carbon dioxide output and respiratory exchange ratio) during immersion showed an initial hyperventilation followed, as immersion proceeded, by a slower metabolic increase due to shivering.
Uragami, Tadashi; Banno, Masashi; Miyata, Takashi
2015-12-10
To obtain high dehydration membranes for an ethanol/water azeotrope, dried blend membranes prepared from mixtures of sodium alginate (Alg-Na) and sodium deoxyribonucleate (DNA-Na) were cross-linked by immersing in a methanol solution of CaCl2 or MaCl2. In the dehydration of an ethanol/water azeotropic mixture by pervaporation, the effects of immersion time in methanol solution of CaCl2 or MaCl2 on the permeation rate and water/ethanol selectivity through Alg-DNA/Ca(2+) and Alg-DNA/Mg(2+) cross-linked membranes were investigated. Alg-DNA/Mg(2+) cross-linked membrane immersed for 12h in methanol solution of MaCl2 exhibited the highest water/ethanol selectivity. This results from depressed swelling of the membranes by formation of a cross-linked structure. However, excess immersion in solution containing cross-linker led to an increase in the hydrophobicity of cross-linked membrane. Therefore, the water/ethanol selectivity of Alg-DNA/Mg(2+) cross-linked membranes with an excess immersion in cross-linking solution was lowered. The relationship between the structure of Alg-DNA/Ca(2+) and Alg-DNA/Mg(2+) cross-linked membranes and their permeation and separation characteristics during pervaporation of an ethanol/water azeotropic mixture is discussed in detail. Copyright © 2015 Elsevier Ltd. All rights reserved.
The substitution of sand filtration by immersed-UF for surface water treatment: pilot-scale studies.
Lihua, Sun; Xing, Li; Guoyu, Zhang; Jie, Chen; Zhe, Xu; Guibai, Li
2009-01-01
The newly issued National Drinking Water Standard required that turbidity should be lower than 1 NTU, and the substitution of sand filtration by immersed ultrafiltration (immersed-UF) is feasible to achieve the standard. This study aimed to optimise the operational processes (i.e. aeration, backwashing) through pilot scale studies, to control membrane fouling while treating the sedimentation effluent. Results indicated that the immersed-UF was promising to treat the sedimentation effluent. The turbidity was below 0.10 NTU, bacteria and E. coli were not detected in the permeate water. The intermittent filtration with aeration is beneficial to inhibit membrane fouling. The critical aeration intensity is observed to be 60.0 m(3) m(-2) h(-1). At this aeration intensity, the decline rate of permeate flux in one period of backwashing was 1.94% and 7.03% for intermittent filtration and sustained filtration respectively. The different membrane backwashing methods (i.e. aeration 1.5 min, synchronous aeration and water backwashing 2 min, water backwashing 1.5 min; synchronous aeration and water backwashing 3 min, water backwashing 2 min; aeration 3 min, single water backwashing 2 min; synchronous aeration and water backwashing 5 min; single water backwashing 5 min) on the recovery of permeate flux were compared, indicating that the synchronous aeration and water backwashing exhibited best potential for permeate flux recovery. The optimal intensity of water backwashing is shown to be 90.0 L m(-2) h(-1). When the actual water intensity was below or exceeded the value, the recovery rate of permeate flux would be reduced. Additionally, the average operating cost for the immersed UF membrane, including the power, the chemical cleaning reagents, and membrane modules replacement, was about 0.31 RMB/m(3).
NASA Astrophysics Data System (ADS)
Picazo-Bueno, José Ángel; Cojoc, Dan; Torre, Vincent; Micó, Vicente
2017-07-01
We present the combination of a single-shot water-immersion digital holographic microscopy with broadband illumination for simultaneous visualization of coherent and incoherent images using microbeads and different biosamples.
Hemodynamic and thermoregulatory responses to lower body water immersion.
Muller, Matthew D; Kim, Cihul-Ho; Seo, Yongsuk; Ryan, Edward J; Glickman, Ellen L
2012-10-01
Lower body water immersion (LBWI) is experienced in the marine industry but the physiological responses to LBWI are unclear. The purpose of the current experiment was to test the effects of water temperature and immersion duration on rectal temperature, heart rate, stroke volume, blood pressure, metabolic rate, and thermal sensation in healthy subjects. Nine young men underwent two 60-min trials of seated LBWI to the iliac crest in a counterbalanced fashion. On one occasion, the water was 35 degrees C (LBWI-Neutral) and on the other it was 13 degrees C (LBWI-Cold); the upper body remained thermoneutral and dry throughout. As expected, exposure to cold water reduced mean skin temperature and individuals reported cold thermal sensation. Mean arterial pressure was significantly higher at 60 min of LBWI-Cold (86 +/- 7 mmHg) compared to LBWI-Neutral (76 +/- 5 mmHg) while heart rate tended to be lower. The change in rectal temperature from baseline to 30 min of LBWI-Cold (delta = -0.01 +/- 0.21degrees C) was significantly smaller than the change in T(re) from 30 to 60 min of LBWI-Cold (delta = -0.46 +/- 0.16 degrees C). Despite this accelerated drop in core temperature during minutes 30-60, metabolic rate did not increase significantly. LBWI-Cold reduces core temperature and increases arterial blood pressure via an increase in total peripheral resistance. This experimental model may help scientists better understand the body during cold stress. Further, people who are occupationally exposed to cold water (when the torso, hands, and arms remain thermoneutral) may be at increased risk for hypothermia.
Lewis, Lucy; Hauck, Yvonne L; Butt, Janice; Western, Chloe; Overing, Helen; Poletti, Corrinne; Priest, Jessica; Hudd, Dawn; Thomson, Brooke
2018-06-19
There is limited research examining midwives' education, knowledge and practice around immersion in water for labour or birth. Our aim was to address this gap in evidence and build knowledge around this important topic. This mixed method study was performed in two phases, between August and December 2016, in the birth centre of a tertiary public maternity hospital in Western Australia. Phase one utilised a cross sectional design to examine perceptions of education, knowledge and practice around immersion in water for labour or birth through a questionnaire. Phase two employed a qualitative descriptive design and focus groups to explore what midwives enjoyed about caring for women who labour or birth in water and the challenges midwives experienced with waterbirth. Frequency distributions were employed for quantitative data. Thematic analysis was undertaken to extract common themes from focus group transcripts. The majority (85%; 29 of 34) of midwives surveyed returned a questionnaire. Results from phase one confirmed that following training, 93% (27 of 29) of midwives felt equipped to facilitate waterbirth and the mean waterbirths required to facilitate confidence was seven. Midwives were confident caring for women in water during the first, second and third stage of labour and enjoyed facilitating water immersion for labour and birth. Finally, responses to labour and birth scenarios indicated midwives were practicing according to state-wide clinical guidance. Phase two included two focus groups of seven and five midwives. Exploration of what midwives enjoyed about caring for women who used water immersion revealed three themes: instinctive birthing; woman-centred atmosphere; and undisturbed space. Exploration of the challenges experienced with waterbirth revealed two themes: learning through reflection and facilities required to support waterbirth. This research contributes to the growing knowledge base examining midwives' education, knowledge and practice around immersion in water for labour or birth. It also highlights the importance of exploring what immersion in water for labour and birth offers midwives, as this research suggests they are integral to sustaining waterbirth as an option for low risk women.
To cool, but not too cool: that is the question--immersion cooling for hyperthermia.
Taylor, Nigel A S; Caldwell, Joanne N; Van den Heuvel, Anne M J; Patterson, Mark J
2008-11-01
Patient cooling time can impact upon the prognosis of heat illness. Although ice-cold-water immersion will rapidly extract heat, access to ice or cold water may be limited in hot climates. Indeed, some have concerns regarding the sudden cold-water immersion of hyperthermic individuals, whereas others believe that cutaneous vasoconstriction may reduce convective heat transfer from the core. It was hypothesized that warmer immersion temperatures, which induce less powerful vasoconstriction, may still facilitate rapid cooling in hyperthermic individuals. Eight males participated in three trials and were heated to an esophageal temperature of 39.5 degrees C by exercising in the heat (36 degrees C, 50% relative humidity) while wearing a water-perfusion garment (40 degrees C). Subjects were cooled using each of the following methods: air (20-22 degrees C), cold-water immersion (14 degrees C), and temperate-water immersion (26 degrees C). The time to reach an esophageal temperature of 37.5 degrees C averaged 22.81 min (air), 2.16 min (cold), and 2.91 min (temperate). Whereas each of the between-trial comparisons was statistically significant (P < 0.05), cooling in temperate water took only marginally longer than that in cold water, and one cannot imagine that the 45-s cooling time difference would have any meaningful physiological or clinical implications. It is assumed that this rapid heat loss was due to a less powerful peripheral vasoconstrictor response, with central heat being more rapidly transported to the skin surface for dissipation. Although the core-to-water thermal gradient was much smaller with temperate-water cooling, greater skin and deeper tissue blood flows would support a superior convective heat delivery. Thus, a sustained physiological mechanism (blood flow) appears to have countered a less powerful thermal gradient, resulting in clinically insignificant differences in heat extraction between the cold and temperate cooling trials.
Vermeirssen, Etiënne L M; Campiche, Sophie; Dietschweiler, Conrad; Werner, Inge; Burkhardt, Michael
2018-05-22
To protect house façades from fouling by microorganisms, biocides can be added to a render or paint before it is applied. During driving rain events, these biocides gradually leach out and have the potential to pollute soil or aquatic ecosystems. We studied the leaching behaviour of biocides and toxicity of leachates from renders with either free or encapsulated biocides. Both render types contained equal amounts of terbutryn, 2-octyl-3(2H)-isothiazolinone (OIT) and 4,5-dichloro-2-n-octyl-4-isothiazolino-3-one (DCOIT). Leachate samples were generated over nine immersion cycles according to a European standard and biocides were quantified. The first and ninth samples were tested using bioassays with algae, bacteria and water flea, the first sample with earthworms and springtails. Encapsulation reduced leaching of terbutryn, OIT and DCOIT four-, 17-, and 27-fold. For aquatic organisms, the toxicity of water from render containing encapsulated biocides was always lower than that of render with free biocides. Furthermore, toxicity decreased four- to five-fold over the nine immersion cycles. Inhibition of photosynthesis was the most sensitive endpoint, followed by algal growth rate, bacterial bioluminescence and water flea reproduction. Toxicity to algae was explained by terbutryn and toxicity to bacteria by OIT. None of the samples affected soil organisms. Results demonstrate that combining standardised leaching tests with standardised bioassays is a promising approach to evaluate the ecotoxicity of biocides that leach from façade renders. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
The effect of different beverages on the color and translucency of flowable composites.
Karadas, Muhammet
2016-11-01
This study examined the changes in color and translucency of flowable composites after immersion in different beverages. Thirty composite samples were prepared from four flowable composites (G-aenial Universal Flo, Filtek Ultimate, Esthelite Flow Quick, and Clearfil Majesty ES Flow) and a microhybrid composite (Filtek Z-250) and stored in distilled water at 37°C for 24 h. The samples were randomly divided into seven groups and then immersed in different beverages (Red Bull, coffee, black tea, Pepsi Cola, orange juice, and distilled water) for 7 days. The CIE L*a*b* values of each sample were measured against white and black backgrounds using a spectrophotometer before and after immersion. Data were analyzed using two-way analysis of variance and Tukey's post-hoc test (p < 0.05). The color changes were significantly different among the composite materials after immersion in beverages (p < 0.05). Filtek Ultimate and Esthelite Flow Quick exhibited less discoloration than did G-aenial Universal Flo and Clearfil Majesty ES Flow. No significant difference was found between Filtek Z-250 and either Filtek Ultimate or Esthelite Flow Quick (p > 0.05). Among the beverages, black tea and coffee caused the highest discoloration of all the materials. Immersion in coffee and black tea resulted in the highest negative changes in the translucency of the materials. The degree of discoloration for the composite resins depended on the material used and drinking beverage. SCANNING 38:701-709, 2016. © 2016 Wiley Periodicals, Inc. © Wiley Periodicals, Inc.
Mousavi, Sayed Ali; Kargar-Dehnavi, Vida; Mousavi, Sayed Amir
2012-01-01
Background: Nickel-titanium (Ni-Ti) rotary instrument files are important devices in Endodontics in root canal preparation. Ni-Ti file breakage is a critical and problematic issue and irrigation techniques were applied to decrease risk of file failure root. The aim of the present study was to compare the temperature gradient change of different irrigation solutions with Ni-Ti rotary instrument system during root canal preparation and also to define their effects on the file failure. Materials and Methods: A novel computerized instrumentation was utilized and thirty standard (ProFile #25/.04) files were divided into three groups and subjected to a filing in the root canal test. Changes in temperature on teeth under constant instrumental conditions with custom-designed computerized experimental apparatus were measured by using a temperature sensor bonded to the apical hole. A rotary instrument for canal preparation in three series of solution was used and the changes in temperature after each solution were compared. Finally, the file failure results were mentored according to each step of test. Comparisons were performed between group status clinically by using ANOVA (t) test, once the sample showed up normal and differences of P<0.01 were considered significant. All data collected were computerized and analyzed for frequency, distribution, and statistical description. Results: There was a decrease in the temperature of the instruments, which were immersed in 5% NaOCl, when compared with the water group (P<0.01). There was also a decrease in the temperature of the instruments immersed in water, when compared with the no solution group (P<0.01). Test results showed that sodium hypochlorite, water, or air of root canals does alter the properties of gradual temperature change and contributes to the failure of the instruments. Conclusion: By immersing the file in 5% NaOCl, the temperature gradient decreased and instrument failure was reduced. PMID:23087732
Vieira, A; Siqueira, A F; Ferreira-Junior, J B; do Carmo, J; Durigan, J L Q; Blazevich, A; Bottaro, M
2016-11-01
This study investigated the effects of 5 and 15°C cold-water immersion on recovery from exercise resulting in exercise-induced muscle damage. 42 college-aged men performed 5×20 drop-jumps and were randomly allocated into one of 3 groups: (1) 5°C; (2) 15°C; or (3) control. After exercise, individuals from the cold-water immersion groups had their lower limbs immerged in iced water for 20 min. Isometric knee extensor torque, countermovement jump, muscle soreness, and creatine kinase were measured before, immediately after, 24, 48, 72, 96 and 168 h post-exercise. There was no between-group difference in isometric strength recovery (p=0.73). However, countermovement jump recovered quicker in cold-water immersion groups compared to control group (p<0.05). Countermovement jump returned to baseline after 72 h in 15°C, 5°C group recovered after 96 h and control did not recovered at any time point measured. Also, creatine kinase returned to baseline at 72 h and remained stable for all remaining measurements for 15°C group, whereas remained elevated past 168 h in both 5°C and control groups. There was a trend toward lower muscle soreness (p=0.06) in 15°C group compared to control at 24 h post-exercise. The result suggests that cold-water immersion promote recovery of stretch-shortening cycle performance, but not influence the recovery of maximal contractile force. Immersion at warmer temperature may be more effective than colder temperatures promoting recovery from strenuous exercise. © Georg Thieme Verlag KG Stuttgart · New York.
Truxton, Tyler T; Miller, Kevin C
2017-09-01
Clinical Scenario: Exertional heat stroke (EHS) is a medical emergency which, if left untreated, can result in death. The standard of care for EHS patients includes confirmation of hyperthermia via rectal temperature (T rec ) and then immediate cold-water immersion (CWI). While CWI is the fastest way to reduce T rec , it may be difficult to lower and maintain water bath temperature in the recommended ranges (1.7°C-15°C [35°F-59°F]) because of limited access to ice and/or the bath being exposed to high ambient temperatures for long periods of time. Determining if T rec cooling rates are acceptable (ie, >0.08°C/min) when significantly hyperthermic humans are immersed in temperate water (ie, ≥20°C [68°F]) has applications for how EHS patients are treated in the field. Are T rec cooling rates acceptable (≥0.08°C/min) when significantly hyperthermic humans are immersed in temperate water? T rec cooling rates of hyperthermic humans immersed in temperate water (≥20°C [68°F]) ranged from 0.06°C/min to 0.19°C/min. The average T rec cooling rate for all examined studies was 0.11±0.06°C/min. Clinical Bottom Line: Temperature water immersion (TWI) provides acceptable (ie, >0.08°C/min) T rec cooling rates for hyperthermic humans post-exercise. However, CWI cooling rates are higher and should be used if feasible (eg, access to ice, shaded treatment areas). Strength of Recommendation: The majority of evidence (eg, Level 2 studies with PEDro scores ≥5) suggests TWI provides acceptable, though not ideal, T rec cooling. If possible, CWI should be used instead of TWI in EHS scenarios.
Sustaining dry surfaces under water
Jones, Paul R.; Hao, Xiuqing; Cruz-Chu, Eduardo R.; Rykaczewski, Konrad; Nandy, Krishanu; Schutzius, Thomas M.; Varanasi, Kripa K.; Megaridis, Constantine M.; Walther, Jens H.; Koumoutsakos, Petros; Espinosa, Horacio D.; Patankar, Neelesh A.
2015-01-01
Rough surfaces immersed under water remain practically dry if the liquid-solid contact is on roughness peaks, while the roughness valleys are filled with gas. Mechanisms that prevent water from invading the valleys are well studied. However, to remain practically dry under water, additional mechanisms need consideration. This is because trapped gas (e.g. air) in the roughness valleys can dissolve into the water pool, leading to invasion. Additionally, water vapor can also occupy the roughness valleys of immersed surfaces. If water vapor condenses, that too leads to invasion. These effects have not been investigated, and are critically important to maintain surfaces dry under water. In this work, we identify the critical roughness scale, below which it is possible to sustain the vapor phase of water and/or trapped gases in roughness valleys – thus keeping the immersed surface dry. Theoretical predictions are consistent with molecular dynamics simulations and experiments. PMID:26282732
The effects of cold immersion and hand protection on grip strength.
Vincent, M J; Tipton, M J
1988-08-01
The maximal voluntary grip strength (MVGS) of male volunteers was examined following a series of five intermittent 2 min cold water (5 degrees C) immersions of the unprotected hand or forearm. MVGS changes due to wearing a protective glove were also investigated. The surface electrical activity over the hand flexor muscles was recorded, as was the skin temperature of the hand and forearm. MVGS decreased significantly (p less than 0.01) following hand immersions (16%) and forearm immersion (13%). The majority of these reductions occurred during the first 2-min period of immersion. The effect of wearing a glove after unprotected hand cooling also produced significant (p less than 0.01) MVGS reductions which averaged 14%. These reductions were in addition to those caused by hand cooling. We conclude that both hand and forearm protection are important for the maintenance of hand-grip strength following cold water immersion.
Zhao, Yun; Xiao, Mei; Tang, Fei; Tang, Wan; Yin, Heng; Sun, Guo-Qiang; Lin, Yin; Zhou, Yong; Luo, Yan; Li, Lu-Man; Tan, Zhi-Hua
2017-10-01
Water immersion delivery is a non-pharmacological approach to ease labor pain. This paper aims to investigate the effect of water immersion delivery on increasing strength of pelvic floor muscle (PFM) and relieving pelvic floor disorders (PFDs) during postpartum period. A total of 2749 vaginal-delivery primiparas in postpartum 6-8 weeks were selected as research objects. Based on the modes of delivery, 600 patients were assigned into water immersion delivery group, 2149 were assigned into conventional delivery group. The scales of PFM strength and pelvic organ prolapsed (POP) were determined by specially trained personnel using digital palpation, and the symptoms of stress urinary incontinence (SUI) were investigated by questionnaire survey. The weak PFM strength was improved by doing Kegel exercise at home for 6-8 weeks. We found that ①The rate of episiotomy in water immersion delivery group was 77.50% (465/600), which was lower than that in conventional delivery group (84.69%, 1820/2149) (P < .01); The primiparas without having an episiotomy have higher PFM strength than those having an episiotomy for both groups (P < .01). ②There was a negative correlation between the scale of PFM strength and SUI or POP, wherein the r-values were -0.135 and -0.435, respectively (P < .01). ③The rate of SUI was 6.50% (39/600) in water immersion delivery group and 6.89% (148/2149) in the conventional delivery group, wherein the intergroup difference was not significant (P > .05); ④The rates of vaginal wall prolapsed and uterus prolapsed were 29.83% (179/600) and 2.83% (17/600) in water immersion delivery group and 30.95% (665/2149) and 4.37% (94/2149) in the conventional delivery group, wherein the intergroup difference was not significant (P > .05). ⑤After Kegel exercise, the strength of PFM was promoted (P < .01). Water immersion delivery has been proved to a beneficial alternative method for conventional delivery method. This delivery mode is associated with fewer episiotomy rate, and avoiding episiotomy is beneficial for maintaining PFM strength of women in postpartum 6-8 weeks. The strength of PFM during postpartum period can be improved by doing Kegel exercise at home.
Zhao, Yun; Xiao, Mei; Tang, Fei; Tang, Wan; Yin, Heng; Sun, Guo-Qiang; Lin, Yin; Zhou, Yong; Luo, Yan; Li, Lu-Man; Tan, Zhi-Hua
2017-01-01
Abstract Background: Water immersion delivery is a non-pharmacological approach to ease labor pain. This paper aims to investigate the effect of water immersion delivery on increasing strength of pelvic floor muscle (PFM) and relieving pelvic floor disorders (PFDs) during postpartum period. Methods: A total of 2749 vaginal-delivery primiparas in postpartum 6-8 weeks were selected as research objects. Based on the modes of delivery, 600 patients were assigned into water immersion delivery group, 2149 were assigned into conventional delivery group. The scales of PFM strength and pelvic organ prolapsed (POP) were determined by specially trained personnel using digital palpation, and the symptoms of stress urinary incontinence (SUI) were investigated by questionnaire survey. The weak PFM strength was improved by doing Kegel exercise at home for 6-8 weeks. Results: We found that ①The rate of episiotomy in water immersion delivery group was 77.50% (465/600), which was lower than that in conventional delivery group (84.69%, 1820/2149) (P < .01); The primiparas without having an episiotomy have higher PFM strength than those having an episiotomy for both groups (P < .01). ②There was a negative correlation between the scale of PFM strength and SUI or POP, wherein the r-values were −0.135 and −0.435, respectively (P < .01). ③The rate of SUI was 6.50% (39/600) in water immersion delivery group and 6.89% (148/2149) in the conventional delivery group, wherein the intergroup difference was not significant (P > .05); ④The rates of vaginal wall prolapsed and uterus prolapsed were 29.83% (179/600) and 2.83% (17/600) in water immersion delivery group and 30.95% (665/2149) and 4.37% (94/2149) in the conventional delivery group, wherein the intergroup difference was not significant (P > .05). ⑤After Kegel exercise, the strength of PFM was promoted (P < .01). Conclusion: Water immersion delivery has been proved to a beneficial alternative method for conventional delivery method. This delivery mode is associated with fewer episiotomy rate, and avoiding episiotomy is beneficial for maintaining PFM strength of women in postpartum 6-8 weeks. The strength of PFM during postpartum period can be improved by doing Kegel exercise at home. PMID:29019880
Physiological responses to prolonged bed rest and fluid immersion in humans
NASA Technical Reports Server (NTRS)
Greenleaf, J. E.
1984-01-01
For many centuries, physicians have used prolonged rest in bed and immersion in water in the treatment of ailments and disease. Both treatments have positive remedial effects. However, adverse physiological responses become evident when patients return to their normal daily activities. The present investigation is concerned with an analysis of the physiological changes during bed rest and the effects produced by water immersion. It is found that abrupt changes in body position related to bed rest cause acute changes in fluid compartment volumes. Attention is given to fluid shifts and body composition, renal function and diuresis, calcium and phosphorus metabolism, and orthostatic tolerance. In a discussion of water immersion, fluid shifts are considered along with cardiovascular-respiratory responses, renal function, and natriuretic and diuretic factors.
NASA Astrophysics Data System (ADS)
Schlagenhauf, Lukas; Kianfar, Bahareh; Buerki-Thurnherr, Tina; Kuo, Yu-Ying; Wichser, Adrian; Nüesch, Frank; Wick, Peter; Wang, Jing
2015-11-01
Weathering processes can influence the surface properties of composites with incorporated nanoparticles. These changes may affect the release behavior of nanoparticles when an abrasion process is applied. Therefore, the influence of two different weathering processes, immersion in water and exposure to UV light, on the properties of abraded particles from a carbon nanotube (CNT)/epoxy nanocomposite was investigated. The investigation included the measurement of the weathering impact on the surface chemistry of the exposed samples, the particle size of abraded particles, the quantity of exposed CNTs in the respirable part of the abraded particles, and the toxicity of abraded particles, measured by in vitro toxicity tests using the THP-1 monocyte-derived macrophages. The results showed that weathering by immersion in water had no influence on the properties of abraded particles. The exposure to UV light caused a degradation of the epoxy on the surface, followed by delamination of an approx. 2.5 μm thick layer. An increased quantity of exposed CNTs in abraded particles was not found; on the contrary, longer UV exposure times decreased the released fraction of CNTs from 0.6% to 0.4%. The toxicity tests revealed that abraded particles from the nanocomposites did not induce additional acute cytotoxic effects compared to particles from the neat epoxy.Weathering processes can influence the surface properties of composites with incorporated nanoparticles. These changes may affect the release behavior of nanoparticles when an abrasion process is applied. Therefore, the influence of two different weathering processes, immersion in water and exposure to UV light, on the properties of abraded particles from a carbon nanotube (CNT)/epoxy nanocomposite was investigated. The investigation included the measurement of the weathering impact on the surface chemistry of the exposed samples, the particle size of abraded particles, the quantity of exposed CNTs in the respirable part of the abraded particles, and the toxicity of abraded particles, measured by in vitro toxicity tests using the THP-1 monocyte-derived macrophages. The results showed that weathering by immersion in water had no influence on the properties of abraded particles. The exposure to UV light caused a degradation of the epoxy on the surface, followed by delamination of an approx. 2.5 μm thick layer. An increased quantity of exposed CNTs in abraded particles was not found; on the contrary, longer UV exposure times decreased the released fraction of CNTs from 0.6% to 0.4%. The toxicity tests revealed that abraded particles from the nanocomposites did not induce additional acute cytotoxic effects compared to particles from the neat epoxy. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr05387k
1983-06-01
NOTES 19. KEY WORDS (Continue on reveree side if necesaary and Identify by block number) Neoprene Synthetic Liners TCE, XR-5, EPDM Hypalon Compatibility...CPE, Hypalon , XR-5, HDPE, Neoprene, and EPDM ) were immersed in TNT, RDX, and TCE solutions for I week. Liner and test .*. method selection and data...Mean Weight Change Values - EPDM /Neoprene Group 57 Unexposed and in Distilled Water 7 Mean Weight Change Values - PVC Group in Distilled 58 Water and in
Thomas, Kate N; van Rij, André M; Lucas, Samuel J E; Cotter, James D
2017-03-01
Passive heat induces beneficial perfusion profiles, provides substantive cardiovascular strain, and reduces blood pressure, thereby holding potential for healthy and cardiovascular disease populations. The aim of this study was to assess acute responses to passive heat via lower-limb, hot-water immersion in patients with peripheral arterial disease (PAD) and healthy, elderly controls. Eleven patients with PAD (age 71 ± 6 yr, 7 male, 4 female) and 10 controls (age 72 ± 7 yr, 8 male, 2 female) underwent hot-water immersion (30-min waist-level immersion in 42.1 ± 0.6°C water). Before, during, and following immersion, brachial and popliteal artery diameter, blood flow, and shear stress were assessed using duplex ultrasound. Lower-limb perfusion was measured also using venous occlusion plethysmography and near-infrared spectroscopy. During immersion, shear rate increased ( P < 0.0001) comparably between groups in the popliteal artery (controls: +183 ± 26%; PAD: +258 ± 54%) and brachial artery (controls: +117 ± 24%; PAD: +107 ± 32%). Lower-limb blood flow increased significantly in both groups, as measured from duplex ultrasound (>200%), plethysmography (>100%), and spectroscopy, while central and peripheral pulse-wave velocity decreased in both groups. Mean arterial blood pressure was reduced by 22 ± 9 mmHg (main effect P < 0.0001, interaction P = 0.60) during immersion, and remained 7 ± 7 mmHg lower 3 h afterward. In PAD, popliteal shear profiles and claudication both compared favorably with those measured immediately following symptom-limited walking. A 30-min hot-water immersion is a practical means of delivering heat therapy to PAD patients and healthy, elderly individuals to induce appreciable systemic (chronotropic and blood pressure lowering) and hemodynamic (upper and lower-limb perfusion and shear rate increases) responses. Copyright © 2017 the American Physiological Society.
Effect of long-time immersion of soft denture liners in water on viscoelastic properties.
Iwasaki, Naohiko; Yamaki, Chisato; Takahashi, Hidekazu; Oki, Meiko; Suzuki, Tetsuya
2017-09-26
Aim of this study was to investigate the effect of long-time immersion of soft denture liners in 37°C water on viscoelastic properties. Six silicone-based and two acrylic resin-based soft denture liners were selected. Cylindrical specimens were stored in distilled water at 37°C for 6 months. Viscoelastic properties, which were instantaneous and delayed elastic displacements, viscous flow, and residual displacement, were determined using a creep meter, and analyzed with 2-way analysis of variance and Tukey's comparison (α=0.05). Viscoelastic properties and their time-dependent changes were varied among materials examined. The observed viscoelastic properties of three from six silicone-based liners did not significantly change after 6-month immersion, but those of two acrylic resin-based liners significantly changed with the increase of immersion time. However, the sum of initial instantaneous elastic displacement and delayed elastic displacement of two acrylic resin-based liners during 6-month immersion changed less than 10%, which might indicate clinically sufficient elastic performance.
NASA Astrophysics Data System (ADS)
Xu, Wenhua; Wang, Zhenyu; Han, En-Hou; Liu, Chunbo
2017-12-01
The failure behavior for two kinds of phenolic-epoxy/tetraglycidyl metaxylediamine composite coatings in 60 °C borax aqueous solution was evaluated using electrochemical methods (EIS) combined with scanning electron microscopy, confocal laser scanning microscope, water immersion test, and Raman spectrum. The main focus was on the effect of curing agent on the corrosion protection of coatings. Results revealed that the coating cured by phenolic modified aromatic amine possessed more compact cross-linked structure, better wet adhesion, lower water absorption (0.064 mg h-1 cm-2) and its impedance values was closed to 108 Ω cm2 after immersion for 576 h, while the coating cured by modified aromatic ring aliphatic amine was lower than 105 Ω cm2. The corrosion mechanism of the two coatings is discussed.
Neuromuscular function during knee extension exercise after cold water immersion.
Wakabayashi, Hitoshi; Wijayanto, Titis; Tochihara, Yutaka
2017-06-23
Human adaptability to cold environment has been focused on in the physiological anthropology and related research area. Concerning the human acclimatization process in the natural climate, it is necessary to conduct a research assessing comprehensive effect of cold environment and physical activities in cold. This study investigated the effect of cold water immersion on the exercise performance and neuromuscular function during maximal and submaximal isometric knee extension. Nine healthy males participated in this study. They performed maximal and submaximal (20, 40, and 60% maximal load) isometric knee extension pre- and post-immersion in 23, 26, and 34 °C water. The muscle activity of the rectus femoris (RF) and vastus lateralis (VL) was measured using surface electromyography (EMG). The percentages of the maximum voluntary contraction (%MVC) and mean power frequency (MPF) of EMG data were analyzed. The post-immersion maximal force was significantly lower in 23 °C than in 26 and 34 °C conditions (P < 0.05). The post-immersion %MVC of RF was significantly higher than pre-immersion during 60% maximal exercise in 23 and 26 °C conditions (P < 0.05). In the VL, the post-immersion %MVC was significantly higher than pre-immersion in 23 and 26 °C conditions during 20% maximal exercise and in 26 °C at 40 and 60% maximal intensities (P < 0.05). The post-immersion %MVC of VL was significantly higher in 26 °C than in 34 °C at 20 and 60% maximal load (P < 0.05). The post-immersion MPF of RF during 20% maximal intensity was significantly lower in 23 °C than in 26 and 34 °C conditions (P < 0.05), and significantly different between three water temperature conditions at 40 and 60% maximal intensities (P < 0.05). The post-immersion MPF of VL during three submaximal trials were significantly lower in 23 and 26 °C than in 34 °C conditions (P < 0.05). The lower shift of EMG frequency would be connected with the decrease in the nerve and muscle fibers conduction velocity. To compensate for the impairment of each muscle fibers function, more muscle fibers might be recruited to maintain the working load. This might result in the greater amplitude of EMG after the cold immersion.
Surface interactions between silica particles and water and organic solvents
DOE Office of Scientific and Technical Information (OSTI.GOV)
Douillard, J.M.; Elwafir, M.; Partyka, S.
1994-04-01
A silica sample has been studied by vapor adsorption and by microcalorimetric methods. The combination of these two methods in the case of water allows one to calculate all the thermodynamic terms related to the adhesion on this silica. Adhesion between silica and miscellaneous solvents has been studied by immersion microcalorimetry. The silica is slightly hydrophobic, but the enthalpy of immersion into water is the most energetic one of all the solvents studied. It appears a clear graduation of the enthalpies of immersion due to the presence of delocalized electrons in the studied solvents.
Chaou, Chung-Hsien; Chen, Chian-Kuang; Chen, Jih-Chang; Chiu, Te-Fa; Lin, Chih-Chuan
2009-08-01
To compare the effectiveness of ice packs and hot water immersion for the treatment of centipede envenomations. Sixty patients envenomated by centipedes were randomized into three groups and were treated with ice packs, hot water immersion, or analgesia injection. The visual analog score (VAS) for pain was measured before the treatment and 15 min afterward. Demographic data and data on local and systemic effects after centipede bites were collected. The VAS scores and the pain decrease (DeltaVAS) were compared between the three groups. All patients suffered from pain at the affected sites; other local effects included redness (n = 49, 81.7%), swelling (n = 32, 53.3%), heat (n = 14, 23.3%), itchiness (n = 5, 8.3), and bullae formation (n = 3, 5.0%). Rare systemic effects were reported. All three groups had similar VAS scores before and after treatment. They also had similar effectiveness in reducing pain caused by centipedes bites (DeltaVAS = 2.55 +/- 1.88, 2.33 +/- 1.78, and 1.55 +/- 1.68, with ice packs, analgesia, and hot water immersion, respectively, p = 0.165). Ice packs, hot water immersion, and analgesics all improved the pain from centipede envenomation. Ice pack treatment is a safe, inexpensive, and non-invasive method for pre-hospital management in patients with centipede envenomation.
Lohitha, K; Prakash, M; Gopinadh, A; Sai Sankar, A J; Sandeep, C H; Sreedevi, B
2016-01-01
Regular usage of denture cleansers is recommended in complete denture wearers for effective plaque control, and these cleansers alter the physical properties of acrylic resin over a period of time. Thus, an in vitro study was carried out to assess the effect of denture cleansers on the color stability of heat-cure denture base resin. The aim of the present study was to evaluate the effect of commercially available fast-acting denture cleansers on the color stability of heat-cure denture base resin at different time intervals. Thirty-six heat-cure acrylic resin (Ivoclar Triplex Hot-V) specimens are randomly allocated into four groups - Group A (distilled water as control); Group B (polident - 3 min); Group C (fixodent scope plus); and Group D (stain away plus) comprising of nine samples each. After recording the baseline values, the specimens were immersed in their respective cleansing solutions for a prescribed time interval. This procedure was repeated daily, and the color change (ΔE) was evaluated after 90 and 180 days interval using a colorimeter in a standard "Commission International de l'Eclairage" color system. Paired t -test and Dunnett's T3 test. All the groups exhibited a variable color change (ΔE) for an immersion period of 90 days. However, significant color differences ( P = 0.001) were noticed among the test groups after 180 days. The color change of denture base resin was greater for Group D followed by Groups B, C, and A respectively after 180 days of immersion. The ΔE values of all test groups increased with time.
NASA Astrophysics Data System (ADS)
Han, Guangdong; Lu, Zhanpeng; Ru, Xiangkun; Chen, Junjie; Xiao, Qian; Tian, Yongwu
2015-12-01
The oxidation behavior of 316L stainless steel specimens after emery paper grounding, mechanical polishing, and electropolishing were investigated in simulated pressurized water reactor primary water at 310 °C for 120 and 500 h. Electropolishing afforded improved oxidation resistance especially during the early immersion stages. Duplex oxide films comprising a coarse Fe-rich outer layer and a fine Cr-rich inner layer formed on all specimens after 500 h of immersion. Only a compact layer was observed on the electropolished specimen after 120 h of immersion. The enrichment of chromium in the electropolished layer contributed to the passivity and protectiveness of the specimen.
Barwood, Martin J.; Corbett, Jo; Massey, Heather; McMorris, Terry; Tipton, Mike; Wagstaff, Christopher R. D.
2018-01-01
Introduction: Drowning is a leading cause of accidental death. In cold-water, sudden skin cooling triggers the life-threatening cold shock response (CSR). The CSR comprises tachycardia, peripheral vasoconstriction, hypertension, inspiratory gasp, and hyperventilation with the hyperventilatory component inducing hypocapnia and increasing risk of aspirating water to the lungs. Some CSR components can be reduced by habituation (i.e., reduced response to stimulus of same magnitude) induced by 3–5 short cold-water immersions (CWI). However, high levels of acute anxiety, a plausible emotion on CWI: magnifies the CSR in unhabituated participants, reverses habituated components of the CSR and prevents/delays habituation when high levels of anxiety are experienced concurrent to immersions suggesting anxiety is integral to the CSR. Purpose: To examine the predictive relationship that prior ratings of acute anxiety have with the CSR. Secondly, to examine whether anxiety ratings correlated with components of the CSR during immersion before and after induction of habituation. Methods: Forty-eight unhabituated participants completed one (CON1) 7-min immersion in to cold water (15°C). Of that cohort, twenty-five completed four further CWIs that would ordinarily induce CSR habituation. They then completed two counter-balanced immersions where anxiety levels were increased (CWI-ANX) or were not manipulated (CON2). Acute anxiety and the cardiorespiratory responses (cardiac frequency [fc], respiratory frequency [fR], tidal volume [VT], minute ventilation [E]) were measured. Multiple regression was used to identify components of the CSR from the most life-threatening period of immersion (1st minute) predicted by the anxiety rating prior to immersion. Relationships between anxiety rating and CSR components during immersion were assessed by correlation. Results: Anxiety rating predicted the fc component of the CSR in unhabituated participants (CON1; p < 0.05, r = 0.536, r2= 0.190). After habituation immersions (i.e., cohort 2), anxiety rating predicted the fR component of the CSR when anxiety levels were lowered (CON2; p < 0.05, r = 0.566, r2= 0.320) but predicted the fc component of the CSR (p < 0.05, r = 0.518, r2= 0.197) when anxiety was increased suggesting different drivers of the CSR when anxiety levels were manipulated; correlation data supported these relationships. Discussion: Acute anxiety is integral to the CSR before and after habituation. We offer a new integrated model including neuroanatomical, perceptual and attentional components of the CSR to explain these data. PMID:29695988
Barwood, Martin J; Corbett, Jo; Massey, Heather; McMorris, Terry; Tipton, Mike; Wagstaff, Christopher R D
2018-01-01
Introduction: Drowning is a leading cause of accidental death. In cold-water, sudden skin cooling triggers the life-threatening cold shock response (CSR). The CSR comprises tachycardia, peripheral vasoconstriction, hypertension, inspiratory gasp, and hyperventilation with the hyperventilatory component inducing hypocapnia and increasing risk of aspirating water to the lungs. Some CSR components can be reduced by habituation (i.e., reduced response to stimulus of same magnitude) induced by 3-5 short cold-water immersions (CWI). However, high levels of acute anxiety, a plausible emotion on CWI: magnifies the CSR in unhabituated participants, reverses habituated components of the CSR and prevents/delays habituation when high levels of anxiety are experienced concurrent to immersions suggesting anxiety is integral to the CSR. Purpose: To examine the predictive relationship that prior ratings of acute anxiety have with the CSR. Secondly, to examine whether anxiety ratings correlated with components of the CSR during immersion before and after induction of habituation. Methods: Forty-eight unhabituated participants completed one (CON1) 7-min immersion in to cold water (15°C). Of that cohort, twenty-five completed four further CWIs that would ordinarily induce CSR habituation. They then completed two counter-balanced immersions where anxiety levels were increased (CWI-ANX) or were not manipulated (CON2). Acute anxiety and the cardiorespiratory responses (cardiac frequency [ f c ], respiratory frequency [ f R ], tidal volume [ V T ], minute ventilation [ E ]) were measured. Multiple regression was used to identify components of the CSR from the most life-threatening period of immersion (1 st minute) predicted by the anxiety rating prior to immersion. Relationships between anxiety rating and CSR components during immersion were assessed by correlation. Results: Anxiety rating predicted the f c component of the CSR in unhabituated participants (CON1; p < 0.05, r = 0.536, r 2 = 0.190). After habituation immersions (i.e., cohort 2), anxiety rating predicted the f R component of the CSR when anxiety levels were lowered (CON2; p < 0.05, r = 0.566, r 2 = 0.320) but predicted the f c component of the CSR ( p < 0.05, r = 0.518, r 2 = 0.197) when anxiety was increased suggesting different drivers of the CSR when anxiety levels were manipulated; correlation data supported these relationships. Discussion: Acute anxiety is integral to the CSR before and after habituation. We offer a new integrated model including neuroanatomical, perceptual and attentional components of the CSR to explain these data.
Chaidez, Cristobal; Lopez, Javier; Vidales, Juan; Campo, Nohelia Castro-Del
2007-08-01
The purpose of this study was to compare chlorinated and ozonated water in reducing Salmonella typhimurium inoculated onto fresh ripe tomatoes. Surface-inoculated tomatoes were immersed/sprayed with chlorinated (200 mg l(-1)) and ozonated water (1 and 2 mg l(-1)) under 2 and 100 nefelometric turbidity units (NTU). Contact times were 120 and 30 s for immersing and spraying applications, respectively. Immersing in chlorinated water and low turbidity resulted in the most effective application with 3.61 log(10) bacterial reduction, while 1 and 2 mg l(-1) of ozone reduced 2.32 and 2.53 log(10), respectively. High turbidity and chlorine reduced the bacterial counts by 3.39 log(10), while 1 and 2 mg l(-1) of ozonated water and low turbidity reduced the bacteria by 1.48 and 1.92 log(10), respectively. Spraying chlorinated water reduced bacteria by 3 log(10), and ozonated water at 1 and 2 mg l(-1) reduced counts by 1.84 and 2.40 log(10), respectively. No statistical differences were found between chlorine and ozone (2 mg l(-1)) during spraying applications (p < 0.05). The use of ozonated water both in immersing and spraying applications is suggested when water turbidity remains low.
Microstructural Changes Due to Alkali-Silica Reaction during Standard Mortar Test
Shin, Jun-Ho; Struble, Leslie J.; Kirkpatrick, R. James
2015-01-01
The microstructural development of mortar bars with silica glass aggregate undergoing alkali-silica reaction (ASR) under the conditions of American Society for Testing and Materials (ASTM) Standard Test C1260 was analyzed using scanning electron microscopy and qualitative X-ray microanalysis. Cracking in the aggregate, the hydrated paste, and the paste-aggregate interface was important in the development of the microstructure. Cracks were characterized according to their location, their relationship to other cracks, and whether they are filled with ASR gel. Expansion of the bars was approximately 1% at 12 days and 2% at 53 days. They fell apart by 63 days. The bars contained two zones, an inner region that was undergoing ASR and an outer and much more highly damaged zone that extended further inward over time. Evidence of ASR was present even during the period when specimens were immersed in water, prior to immersion in NaOH solution. PMID:28793711
Microstructural Changes Due to Alkali-Silica Reaction during Standard Mortar Test
Shin, Jun-Ho; Struble, Leslie; Kirkpatrick, R.
2015-12-01
The microstructural development of mortar bars with silica glass aggregate undergoing alkali-silica reaction (ASR) under the conditions of American Society for Testing and Materials (ASTM) Standard Test C1260 was analyzed using scanning electron microscopy and qualitative X-ray microanalysis. Cracking in the aggregate, the hydrated paste, and the paste-aggregate interface was important in the development of the microstructure. Cracks were characterized according to their location, their relationship to other cracks, and whether they are filled with ASR gel. Expansion of the bars was approximately 1% at 12 days and 2% at 53 days. They fell apart by 63 days. The barsmore » contained two zones, an inner region that was undergoing ASR and an outer and much more highly damaged zone that extended further inward over time. Evidence of ASR was present even during the period when specimens were immersed in water, prior to immersion in NaOH solution.« less
Microstructural Changes Due to Alkali-Silica Reaction during Standard Mortar Test.
Shin, Jun-Ho; Struble, Leslie J; Kirkpatrick, R James
2015-12-02
The microstructural development of mortar bars with silica glass aggregate undergoing alkali-silica reaction (ASR) under the conditions of American Society for Testing and Materials (ASTM) Standard Test C1260 was analyzed using scanning electron microscopy and qualitative X-ray microanalysis. Cracking in the aggregate, the hydrated paste, and the paste-aggregate interface was important in the development of the microstructure. Cracks were characterized according to their location, their relationship to other cracks, and whether they are filled with ASR gel. Expansion of the bars was approximately 1% at 12 days and 2% at 53 days. They fell apart by 63 days. The bars contained two zones, an inner region that was undergoing ASR and an outer and much more highly damaged zone that extended further inward over time. Evidence of ASR was present even during the period when specimens were immersed in water, prior to immersion in NaOH solution.
Further damage induced by water in micro-indentations in phosphate laser glass
NASA Astrophysics Data System (ADS)
Yu, Jiaxin; Jian, Qingyun; Yuan, Weifeng; Gu, Bin; Ji, Fang; Huang, Wen
2014-02-01
Using a microhardness tester, artificial flaws were made by micro-indentation in N31 Nd-doped phosphate laser glass. Indentation fracture toughness, KIC, was estimated as 0.45-0.53 MPa m1/2 from these indentations. The glasses with indentations were then immersed in ultrapure water to investigate further water-induced damage of these indentations. Stress-enhanced hydrolysis leads to the propagations of radial crack, lateral cracks and microcracks in the subsurface. These crack propagations therefore cause deformation in subsurface to form annular reflections regions around the indentations and further material collapse within imprints. After the residual stresses are exhausted, the leaching plays a more dominated role in glass corrosion in the further immersion. After immersion, the material structure slackens around micro-indentation, which decreases the contact stiffness and results in a lower nano-hardness. For the surface far away from flaws, water immersion presents a weak effect on the near-surface mechanical since the matrix leaching in phosphate glass restricts the formation of hydration layer. During first 20 min immersion, due to higher chemical activity and lower fracture toughness, the radial cracks show a faster propagation in phosphate glass compared with that in K9 silicate glass. For further immersion, crack healing occurs in silicate glass but not in phosphate glass. Analysis shows that the formation of hydration layer on crack walls plays an important role in crack healing in glasses.
Dry coupling for whole-body small-animal photoacoustic computed tomography
NASA Astrophysics Data System (ADS)
Yeh, Chenghung; Li, Lei; Zhu, Liren; Xia, Jun; Li, Chiye; Chen, Wanyi; Garcia-Uribe, Alejandro; Maslov, Konstantin I.; Wang, Lihong V.
2017-04-01
We have enhanced photoacoustic computed tomography with dry acoustic coupling that eliminates water immersion anxiety and wrinkling of the animal and facilitates incorporating complementary modalities and procedures. The dry acoustic coupler is made of a tubular elastic membrane enclosed by a closed transparent water tank. The tubular membrane ensures water-free contact with the animal, and the closed water tank allows pressurization for animal stabilization. The dry coupler was tested using a whole-body small-animal ring-shaped photoacoustic computed tomography system. Dry coupling was found to provide image quality comparable to that of conventional water coupling.
Kohli, Shivani; Bhatia, Shekhar
2015-01-01
Proper function, esthetics, and cost are the prime factors to be considered while selecting bridge veneering materials. The purpose of the study is to evaluate color durability of acrylic veneer materials after immersion in common beverages at different time intervals. Spectrophotometer was used for taking color measurements based on the transmission of light through the specimens made of the selected materials which were Tooth moulding powder (DPI) and Acrylux (Ruthinium). Thirty specimens of standardized dimensions were prepared from each material. The specimens were divided into three groups of 10 each. One group of each material was immersed in tea (TajMahal) and another group of each material in cola (Pepsi) as the staining solutions. The remaining group of 10 from each material served as control and was stored in distilled water. Color measurements were obtained pre-immersion, and after 1, 15, and 30 days of immersion. Tooth moulding powder displayed better color durability than Acrylux over the 1 month immersion period in both staining solutions. Tea resulted in more discoloration compared to cola (Pepsi). The difference in the color durability of Acrylux and Tooth moulding powder may be attributed to the differences in the composition of tested resin veneering materials, i.e. their polar properties, which contribute to the absorption of staining solution, and the different brands and the strengths of the solutions.
The physiological response to cold-water immersion following a mixed martial arts training session.
Lindsay, Angus; Carr, Sam; Cross, Sean; Petersen, Carl; Lewis, John G; Gieseg, Steven P
2017-05-01
Combative sport is one of the most physically intense forms of exercise, yet the effect of recovery interventions has been largely unexplored. We investigated the effect of cold-water immersion on structural, inflammatory, and physiological stress biomarkers following a mixed martial arts (MMA) contest preparation training session in comparison with passive recovery. Semiprofessional MMA competitors (n = 15) were randomly assigned to a cold-water immersion (15 min at 10 °C) or passive recovery protocol (ambient air) completed immediately following a contest preparation training session. Markers of muscle damage (urinary myoglobin), inflammation/oxidative stress (urinary neopterin + total neopterin (neopterin + 7,8-dihydroneopterin)), and hypothalamic-pituitary axis (HPA) activation (saliva cortisol) were determined before, immediately after, and 1, 2, and 24 h postsession. Ratings of perceived soreness and fatigue, counter movement jump, and gastrointestinal temperature were also measured. Concentrations of all biomarkers increased significantly (p < 0.05) postsession. Cold water immersion attenuated increases in urinary neopterin (p < 0.05, d = 0.58), total neopterin (p < 0.05, d = 0.89), and saliva cortisol after 2 h (p < 0.05, d = 0.68) and urinary neopterin again at 24 h (p < 0.01, d = 0.57) in comparison with passive recovery. Perceived soreness, fatigue, and gastrointestinal temperatures were also lower for the cold-water immersion group at several time points postsession whilst counter movement jump did not differ. Combative sport athletes who are subjected to impact-induced stress may benefit from immediate cold-water immersion as a simple recovery intervention that reduces delayed onset muscle soreness as well as macrophage and HPA activation whilst not impairing functional performance.
NASA Astrophysics Data System (ADS)
Bilgunde, Prathamesh N.; Bond, Leonard J.
2018-04-01
Ultrasonic imaging is a key enabling technology required for in-service inspection of advanced sodium fast reactors at the hot stand-by operating mode (˜250C). Current work presents development of a single element, 2.4MHz, planar, ultrasonic immersion transducer for a potential application in ranging, inspection and imaging of the reactor components. The prototype immersion transducer is first tested in water for three thermal cycles up to 92C. The transducer is further evaluated for four thermal cycles in silicone oil, with total seven thermal cycles that exceeded operation period of 21 hours. Moreover, the preliminary data acquired for speed of sound in silicone oil indicates 24% reduction from 22C to 142C. Sensitivity of the ultrasonic transducer is also measured as a function of temperature and demonstrates the effect of multiple thermal cycles on the transducer components.
Pathogenesis of sudden death following water immersion (immersion syndrome)
NASA Technical Reports Server (NTRS)
Buhring, M.; Spies, H. F.
1981-01-01
Sympathetic activity under cold stress is investigated. Predominantly vagal cardio-depressive reflexes are discussed besides currently known mechanisms of sudden death after water immersion. Pronounced circulatory centralization in diving animals as well as following exposure in cold water indicates additional sympathetic activity. In cold water baths of 15 C, measurements indicate an increase in plasma catecholamine levels by more than 300 percent. This may lead to cardiac arrhythmias by the following mechanisms: cold water essentially induces sinus bradycardia; brady-and tachycardiarrhythmias may supervene as secondary complications; sinusbradycardia may be enhanced by sympathetic hypertonus. Furthermore, ectopic dysrhythmias are liable to be induced by the strictly sympathetic innervation of the ventricle. Myocardial ischemia following a rise in peripheral blood pressure constitutes another arrhythmogenic factor. Some of these reactions are enhanced by alcohol intoxication.
Ethanol postpolymerization treatment for improving the biocompatibility of acrylic reline resins.
Neves, Cristina B; Lopes, Luís P; Ferrão, Helena F; Miranda, Joana P; Castro, Matilde F; Bettencourt, Ana F
2013-01-01
To evaluate the effect of postpolymerization treatment based on ethanol-aqueous solutions on the residual monomer (RM) content, flexural strength, microhardness, and cytotoxicity of hard chairside reline resins (Kooliner, Ufi Gel Hard). After polymerization, specimens were immersed in water, 20%, 50%, or 70% ethanol solutions at 23°C or 55°C for 10 minutes. Controls were left untreated. HPLC was used for the determination of RM content. Specimens were submitted to Vickers microhardness and 3-point loading flexural strength tests. Cytotoxicity of resin eluates was determined on human fibroblasts by assessing cellular mitochondrial function and lactate dehydrogenase release. Higher concentrations of ethanol promoted lower RM content at 55°C in both materials. The mechanical properties were maintained after 50% and 20% ethanol treatments in Kooliner and Ufi Gel Hard, respectively. Specimens submitted to those treatments showed significant reduction on cytotoxicity compared to immersion in hot water, the treatment of choice in the recent literature. Immersion of relined dentures in specific ethanol solutions at 55°C for 10 minutes can be considered an effective postpolymerization treatment contributing to increase materials biocompatibility. The proposed protocol is expeditious and easy to achieve with simple equipment in a dental office.
7 CFR 305.22 - Hot water immersion treatment schedules.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 5 2010-01-01 2010-01-01 false Hot water immersion treatment schedules. 305.22 Section 305.22 Agriculture Regulations of the Department of Agriculture (Continued) ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE PHYTOSANITARY TREATMENTS Heat Treatments § 305.22...
Cardiovascular response to apneic immersion in cool and warm water
NASA Technical Reports Server (NTRS)
Folinsbee, L.
1974-01-01
The influence of prior exposure to cool water and the influence of lung volume on the responses to breath holding were examined. The bradycardia and vasoconstriction that occur during breath-hold diving in man are apparently the resultant of stimuli from apnea, relative expansion of the thorax, lung volume, esophageal pressure, face immersion, and thermal receptor stimulation. It is concluded that the bradycardia and vasoconstriction associated with breath holding during body immersion are not attenuated by a preexisting bradycardia and vasoconstriction due to cold.
1985-06-01
34 insulated garments excluded cold-water entry, tightness-of-fit was not an important factor in thermal performance. The "dry" garments in this study were...Supplemertary Notes I 16. Abstruct The puirpose of this study was to caopare the protection against immersion hypothermia provided by various types of Coat...survival tize pro ons fron calmr-veter studies . 17. Key Words 18. Distribution Statement Hypothermia Rough water Immersion Protective clothing Sea
Thomas, Kate N; van Rij, André M; Lucas, Samuel J E; Gray, Andrew R; Cotter, James D
2016-01-01
Exercise induces arterial flow patterns that promote functional and structural adaptations, improving functional capacity and reducing cardiovascular risk. While heat is produced by exercise, local and whole-body passive heating have recently been shown to generate favorable flow profiles and associated vascular adaptations in the upper limb. Flow responses to acute heating in the lower limbs have not yet been assessed, or directly compared to exercise, and other cardiovascular effects of lower-limb heating have not been fully characterized. Lower-limb heating by hot-water immersion (30 min at 42°C, to the waist) was compared to matched-duration treadmill running (65-75% age-predicted heart rate maximum) in 10 healthy, young adult volunteers. Superficial femoral artery shear rate assessed immediately upon completion was increased to a greater extent following immersion (mean ± SD: immersion +252 ± 137% vs. exercise +155 ± 69%, interaction: p = 0.032), while superficial femoral artery flow-mediated dilation was unchanged in either intervention. Immersion increased heart rate to a lower peak than during exercise (immersion +38 ± 3 beats·min -1 vs. exercise +87 ± 3 beats·min -1 , interaction: p < 0.001), whereas only immersion reduced mean arterial pressure after exposure (-8 ± 3 mmHg, p = 0.012). Core temperature increased twice as much during immersion as exercise (+1.3 ± 0.4°C vs. +0.6 ± 0.4°C, p < 0.001). These data indicate that acute lower-limb hot-water immersion has potential to induce favorable shear stress patterns and cardiovascular responses within vessels prone to atherosclerosis. Whether repetition of lower-limb heating has long-term beneficial effects in such vasculature remains unexplored.
Habituation of the metabolic and ventilatory responses to cold-water immersion in humans.
Tipton, Michael J; Wakabayashi, Hitoshi; Barwood, Martin J; Eglin, Clare M; Mekjavic, Igor B; Taylor, Nigel A S
2013-01-01
An experiment was undertaken to answer long-standing questions concerning the nature of metabolic habituation in repeatedly cooled humans. It was hypothesised that repeated skin and deep-body cooling would produce such a habituation that would be specific to the magnitude of the cooling experienced, and that skin cooling alone would dampen the cold-shock but not the metabolic response to cold-water immersion. Twenty-one male participants were divided into three groups, each of which completed two experimental immersions in 12°C water, lasting until either rectal temperature fell to 35°C or 90min had elapsed. Between these two immersions, the control group avoided cold exposures, whilst two experimental groups completed five additional immersions (12°C). One experimental group repeatedly immersed for 45min in average, resulting in deep-body (1.18°C) and skin temperature reductions. The immersions in the second experimental group were designed to result only in skin temperature reductions, and lasted only 5min. Only the deep-body cooling group displayed a significantly blunted metabolic response during the second experimental immersion until rectal temperature decreased by 1.18°C, but no habituation was observed when they were cooled further. The skin cooling group showed a significant habituation in the ventilatory response during the initial 5min of the second experimental immersion, but no alteration in the metabolic response. It is concluded that repeated falls of skin and deep-body temperature can habituate the metabolic response, which shows tissue temperature specificity. However, skin temperature cooling only will lower the cold-shock response, but appears not to elicit an alteration in the metabolic response. Copyright © 2012 Elsevier Ltd. All rights reserved.
POP, SILVIA IZABELLA; DUDESCU, MIRCEA; MERIE, VIOLETA VALENTINA; PACURAR, MARIANA; BRATU, CRISTINA DANA
2017-01-01
Background and aims This experimental study mainly aims at comparing the most important mechanical properties of the new orthodontic archwires, those immersed in fluorinated solution, the as-retrieved ones and the intra-oral used ones. Methods A total of 270 arch wires were tested, using tensile testing and three-point bending tests. The tested archwires were made of Stainless Steel, Nickel Titanium, Beta-Titanium and physiognomic covered Nickel Titanium. The tested archwires were subjected to three types of treatments: immersion into fluorinated solution, immersion into carbonated drinks and intra-oral use. Results The immersion caused variations of the activation and deactivation forces of all arch wires. The most affected arch wires, in terms of bending characteristics, were the intra-oral used ones. Conclusions The alteration of mechanical properties of the orthodontic arch wires by their immersion into fluorinated solutions and soft drinks could not be statistically demonstrated. PMID:28781528
46 CFR 160.171-19 - Approval testing for child size immersion suit.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 6 2012-10-01 2012-10-01 false Approval testing for child size immersion suit. 160.171... Approval testing for child size immersion suit. A child size suit must pass the following tests: (a) The stability test prescribed in § 160.171-17(c)(8), except that only six children need be used as test subjects...
46 CFR 160.171-19 - Approval testing for child size immersion suit.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 6 2010-10-01 2010-10-01 false Approval testing for child size immersion suit. 160.171... Approval testing for child size immersion suit. A child size suit must pass the following tests: (a) The stability test prescribed in § 160.171-17(c)(8), except that only six children need be used as test subjects...
46 CFR 160.171-19 - Approval testing for child size immersion suit.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 6 2013-10-01 2013-10-01 false Approval testing for child size immersion suit. 160.171... Approval testing for child size immersion suit. A child size suit must pass the following tests: (a) The stability test prescribed in § 160.171-17(c)(8), except that only six children need be used as test subjects...
46 CFR 160.171-19 - Approval testing for child size immersion suit.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 6 2011-10-01 2011-10-01 false Approval testing for child size immersion suit. 160.171... Approval testing for child size immersion suit. A child size suit must pass the following tests: (a) The stability test prescribed in § 160.171-17(c)(8), except that only six children need be used as test subjects...
46 CFR 160.171-19 - Approval testing for child size immersion suit.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 6 2014-10-01 2014-10-01 false Approval testing for child size immersion suit. 160.171... Approval testing for child size immersion suit. A child size suit must pass the following tests: (a) The stability test prescribed in § 160.171-17(c)(8), except that only six children need be used as test subjects...
Jaramillo Mejía, Santiago; Albertó, Edgardo
2013-01-01
The oyster mushroom, Pleurotus ostreatus, is cultivated worldwide. It is one of the most appreciated mushrooms due to its high nutritional value. Immersion of the substrate in hot water is one of the most popular and worldwide treatment used for mushroom farmers. It is cheap and easy to implement. To compare the yields obtained during mushroom production of P. ostreatus using different pre-treatments (immersion in hot water, sterilization by steam and the use of fungicide) to determine if they influence mushroom crop. Four different treatments of substrate (wheat straw) were carried out: (i) immersion in hot water (IHW); (ii) steam sterilization; (iii) chemical; and (iv) untreated. The residual water from the IHW treatment was used to evaluate the mycelium growth and the production of P. ostreatus. Carbendazim treatment produced highest yields (BE: 106.93%) while IHW produced the lowest BE with 75.83%. Sugars, N, P, K and Ca were found in residual water of IHW treatment. The residual water increased the mycelium growth but did not increase yields. We have proved that IHW treatment of substrate reduced yields at least 20% when compared with other straw treatments such as steam, chemical or untreated wheat straw. Nutrients like sugars, proteins and minerals were found in the residual water extract which is the resultant water where the immersion treatment is carried out. The loss of these nutrients would be the cause of yield decrease. Alternative methods to the use of IHW as treatment of the substrate should be considered to reduce economical loss. Copyright © 2012 Revista Iberoamericana de Micología. Published by Elsevier Espana. All rights reserved.
Effect of dehydration on thirst and drinking during immersion in men
NASA Technical Reports Server (NTRS)
Sagawa, S.; Miki, K.; Tajima, F.; Tanaka, H.; Choi, J. K.; Keil, L. C.; Shiraki, K.; Greenleaf, J. E.
1992-01-01
The effect of water immersion on voluntary water intake, subjective evaluations of thirst and gastrointestinal state, and associated fluid-electrolyte and hormonal interaction were investigated. Eight men (19-25 yrs of age) were immersed to the neck while sitting for three hours at 34.5 C or in air at 28 C when euhydrated and hypohydrated by 3.6 percent body weight loss. Within the first ten minutes of immersion the significant reduction in drinking in the hypo-H2O experiment was associated with unchanged plasma Na(+), plasma osmolality, heart rates, and mean arterial pressures. Different responses increased cardiac output, plasma volume, and atrial natriuretic peptides and decreased plasma renin activity and arginine vasopressin. It is concluded that the extracellular pathway, as opposed to the osmotic pathway, appears to be the major mechanism for immersion-induced suppression of drinking.
Slime Analysis of Painted Steel Panels Immersed in Biscayne Bay, Miami Beach, Florida.
1981-03-30
site ploratory tests on materials under consideration for water. Since the sample panels are curved to fit the heat exchangers was undertaken to... tested in this program were standard and experimental Navy materials and a selection of proprietary coatings supplied by coinrcial manufacturers. Navy...of marine microbial slime fouling filims. Application Is described to fouling of metal heat exchanger pipe in the Ocean Thermal Enrgy Conversion
NASA Astrophysics Data System (ADS)
Shimonishi, Y.; Zhang, T.; Johnson, P.; Imanishi, N.; Hirano, A.; Takeda, Y.; Yamamoto, O.; Sammes, N.
The stability of a NASICON-type lithium ion conducting solid electrolyte, Li 1+ x+ yTi 2- xAl xP 3- ySi yO 12 (LTAP), in acetic acid and formic acid solutions was examined. XRD patterns of the LTAP powders immersed in 100% acetic acid and formic acid at 50 °C for 4 months showed no change as compared to the pristine LTAP. However, the electrical conductivity of LTAP drastically decreased. On the other hand, no significant electrical conductivity change of LTAP immersed in lithium formate saturated formic acid-water solution was observed, and the electrical conductivity of LTAP immersed in lithium acetate saturated acetic acid-water increased. Cyclic voltammogram tests suggested that acetic acid was stable up to a high potential, but formic acid decomposed under the decomposition potential of water. The acetic acid solution was considered to be a candidate for the active material in the air electrode of lithium-air rechargeable batteries. The cell reaction was considered as 2Li + 2 CH 3COOH + 1/2O 2 = 2CH 3COOLi + H 2O. The energy density of this lithium-air system is calculated to be 1477 Wh kg -1 from the weights of Li and CH 3COOH, and an observed open-circuit voltage of 3.69 V.
46 CFR 160.021-4 - Approval and production tests.
Code of Federal Regulations, 2010 CFR
2010-10-01
... by the manufacturer to correct the problem. Samples from the rejected lot must be retested in order...-resistant coating on the signal plus packaging in a sealed plastic waterproof bag, the 24-hour water immersion conditioning will be conducted while the signal is in the sealed plastic waterproof bag and will...
46 CFR 160.021-4 - Approval and production tests.
Code of Federal Regulations, 2011 CFR
2011-10-01
... by the manufacturer to correct the problem. Samples from the rejected lot must be retested in order...-resistant coating on the signal plus packaging in a sealed plastic waterproof bag, the 24-hour water immersion conditioning will be conducted while the signal is in the sealed plastic waterproof bag and will...
46 CFR 160.037-4 - Approval and production tests.
Code of Federal Regulations, 2010 CFR
2010-10-01
... by the manufacturer to correct the problem. Samples from the rejected lot must be retested in order... signal plus packaging in a sealed plastic waterproof bag, the 24-hour water immersion conditioning will be conducted while the signal is in the sealed plastic waterproof bag and will be followed by an...
46 CFR 160.037-4 - Approval and production tests.
Code of Federal Regulations, 2011 CFR
2011-10-01
... by the manufacturer to correct the problem. Samples from the rejected lot must be retested in order... signal plus packaging in a sealed plastic waterproof bag, the 24-hour water immersion conditioning will be conducted while the signal is in the sealed plastic waterproof bag and will be followed by an...
Investigation of EBT3 radiochromic film's response to humidity.
León-Marroquín, Elsa Y; Lárraga-Gutiérrez, José M; Herrera-González, J Alfredo; Camacho-López, Miguel A; Villarreal Barajas, José E; García-Garduño, Olivia A
2018-05-01
The aim of this work is to investigate the effects of immersing EBT3 radiochromic film in water and to evaluate its contribution to the total uncertainty in dose determination. We used 3 cm × 3 cm EBT3 radiochromic films irradiated in the range of 0-70 Gy to study the impact of water immersion on the change in net optical density. These films were placed in a water container for a period of 24 h. The net optical density was measured before (0 h) and after of the immersion in water (1, 3, 6, 12, 18, and 24 h). The absorbance spectrum of the EBT3 radiochromic film was measured at 0 h and 24 h after immersion in water. The uncertainty in dose determination due to the effects of keeping the EBT3 radiochromic film submerged in water at 0, 1, and 24 h were recorded in the red, green, and blue channels. We observed an increase in the net optical density as an effect on the film due to its immersion in water. The penetration of the water at the edges of the radiochromic film was observed to be a function of time during which the film remained in the water. On the other hand, the penetration of water at the edges of the film was found to be independent of irradiation dose. EBT3 radiochromic film is found more resistant to water penetration through the edges than its predecessors. However, there is evidence that suggest that liquid water damage the Nylon cover layer of the film by changing its optical properties. Therefore, it is recommended to build a new calibration curve for radiochromic films for a specific situation involving dose measurements in liquid water. © 2018 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.
Study on Surface Permeability of Concrete under Immersion
Liu, Jun; Xing, Feng; Dong, Biqin; Ma, Hongyan; Pan, Dong
2014-01-01
In this paper, concrete specimens are immersed in ultrapure water, to study the evolutions of surface permeability, pore structure and paste microstructure following the prolonging of immersion period. According to the results, after 30-day immersion, the surface permeability of concrete becomes higher as compared with the value before immersion. However, further immersion makes the surface permeability decrease, so that the value measured after 150-day immersion is only half that measured after 30-day immersion. The early increase in surface permeability should be mainly attributed to the leaching of calcium hydroxide, while the later decrease to the refinement of pore structure due to hydration. The two effects work simultaneously and compete throughout the immersion period. The proposed mechanisms get support from microscopic measurements and observations. PMID:28788490
Method and apparatus for measuring surface contour on parts with elevated temperatures
Horvath, Mark S.; Nance, Roy A.; Cohen, George H.; Fodor, George
1991-01-01
The invention is directed to a method and apparatus for measuring the surface contour of a test piece, such as the bow of a radioactive fuel rod, which is completely immersed in water. The invention utilizes ultrasonic technology and is capable of measuring surface contours of test pieces which are at a higher temperature than the surrounding water. The presence of a test piece at a higher temperature adversely affects the distance measurements by causing thermal variations in the water near the surface of the test piece. The contour measurements depend upon a constant temperature of the water in the path of the ultrasonic wave to provide a constant acoustical velocity (the measurement is made by the time of flight measurement for an ultrasonic wave). Therefore, any variations of water temperature near the surface will introduce errors degrading the measurement. The present invention overcomes these problems by assuring that the supply of water through which the ultrasonic waves travel is at a predetermined and constant temperature.
[Water immersion as an anti-g protection for pilot. Pro et contra].
Barer, A S
2007-01-01
In the period of 1988 - 1990 the ZVEZDA Aerospace medicine Department fulfilled comprehensive physiological investigations in order to assess the prospects for water immersion as an anti-g gear for pilots of high-maneuver aircraft. Both dry and open water immersion methods were used. More than 150 centrifuge runs were conducted to define limits for the acceleration value and time of 9-g tolerance. Volunteered subjects in the pilot's posture were inclined at 35 degrees and 55 degrees to the total inertial force vector. The obvious subjective discomfort felt during acceleration and absence of clinical aftereffect were qualified as a positive outcome. The subjects were ready for repeated runs even after a very brief repose. The main impediment to the professional anti-g use of immersion is visual disorders which in this case are not predictors of coming loss of consciousness and attributed to alterations in regional hemodynamics. The authors assert that there is a good reason to continue search for implementation of the immersion principle in g-protection of pilots to reduce the rate of professional pathologies and to intensify flights.
Probability of survival during accidental immersion in cold water.
Wissler, Eugene H
2003-01-01
Estimating the probability of survival during accidental immersion in cold water presents formidable challenges for both theoreticians and empirics. A number of theoretical models have been developed assuming that death occurs when the central body temperature, computed using a mathematical model, falls to a certain level. This paper describes a different theoretical approach to estimating the probability of survival. The human thermal model developed by Wissler is used to compute the central temperature during immersion in cold water. Simultaneously, a survival probability function is computed by solving a differential equation that defines how the probability of survival decreases with increasing time. The survival equation assumes that the probability of occurrence of a fatal event increases as the victim's central temperature decreases. Generally accepted views of the medical consequences of hypothermia and published reports of various accidents provide information useful for defining a "fatality function" that increases exponentially with decreasing central temperature. The particular function suggested in this paper yields a relationship between immersion time for 10% probability of survival and water temperature that agrees very well with Molnar's empirical observations based on World War II data. The method presented in this paper circumvents a serious difficulty with most previous models--that one's ability to survive immersion in cold water is determined almost exclusively by the ability to maintain a high level of shivering metabolism.
Exercise thermoregulation in men after 6 hours of immersion
NASA Technical Reports Server (NTRS)
Greenleaf, J. E.; Spaul, W. A.; Kravik, S. E.; Wong, N.; Elder, C. A.
1985-01-01
The present investigation is concerned with thermoregulation at rest and during exercise after water-immersion deconditioning, giving particular attention to the effects of fluid shifts and negative water balance on sweat rate and rectal temperature. Six healthy males 20-35 years old were used in the experiments. Rectal and mean skin temperature, skin heat conductance, heart rate, and total body sweat rate were measured during 70 min of supine leg exercise at 50 percent of peak O2 uptake. The data were taken after a 6-h control period in air and after immersion to the neck in water (34.5 C) for 6 h after overnight food and fluid restriction. Attention is given to end exercise heart rates and data during exercise. The obtained results suggest that, compared with control responses, the equilibrium level of core temperature during submaximal exercise is regulated at a higher level after immersion.
Kjeld, Thomas; Pott, Frank C; Secher, Niels H
2009-04-01
The diving response is initiated by apnea and facial immersion in cold water and includes, besides bradycardia, peripheral vasoconstriction, while cerebral perfusion may be enhanced. This study evaluated whether facial immersion in 10 degrees C water has an independent influence on cerebral perfusion evaluated as the middle cerebral artery mean flow velocity (MCA V(mean)) during exercise in nine male subjects. At rest, a breath hold of maximum duration increased the arterial carbon dioxide tension (Pa(CO(2))) from 4.2 to 6.7 kPa and MCA V(mean) from 37 to 103 cm/s (mean; approximately 178%; P < 0.001). Similarly, during 100-W exercise, a breath hold increased Pa(CO(2)) from 5.9 to 8.2 kPa (P < 0.001) and MCA V(mean) from 55 to 113 cm/s ( approximately 105%), and facial immersion further increased MCA V(mean) to 122 cm/s ( approximately 88%; both P < 0.001). MCA V(mean) also increased during 180-W exercise (from 47 to 53 cm/s), and this increment became larger with facial immersion (76 cm/s, approximately 62%; P < 0.001), although Pa(CO(2)) did not significantly change. These results indicate that a breath hold diverts blood toward the brain with a >100% increase in MCA V(mean), largely because Pa(CO(2)) increases, but the increase in MCA V(mean) becomes larger when combined with facial immersion in cold water independent of Pa(CO(2)).
Internalization of Listeria monocytogenes in cantaloupes during dump tank washing and hydrocooling.
Macarisin, Dumitru; Wooten, Anna; De Jesus, Antonio; Hur, Minji; Bae, Seonjae; Patel, Jitendra; Evans, Peter; Brown, Eric; Hammack, Thomas; Chen, Yi
2017-09-18
Recent listeriosis outbreaks and recalls associated with cantaloupes urge for studies to understand the mechanisms of cantaloupe contamination by Listeria monocytogenes. Postharvest practices such as washing and hydrocooling were suggested to facilitate the contamination of fresh fruits by human pathogens. This study assessed the potential of L. monocytogenes internalization into cantaloupes during dump tank washing and immersion-type hydrocooling in water contaminated with L. monocytogenes. The effect of cantaloupe cultivar, water temperature, and harvesting technique on L. monocytogenes internalization was also evaluated. Full slip (cantaloupe without any residual stem) Western and Eastern cultivar cantaloupes were pre-warmed to 42°C (to imitate peak-high field temperatures of freshly harvested cantaloupes) and then immersed in water at 6°C and 18°C containing 4 and 6logCFU/ml of L. monocytogenes. Clipped (cantaloupe with short stem residues obtained by clipping the stem at harvest) Western and Eastern cantaloupes were pre-warmed to 42°C and then immersed in water at 6°C containing 6logCFU/ml of L. monocytogenes. Additionally, full slip and clipped Western cantaloupes were equilibrated to 18°C and then immersed in water at 18°C containing 6logCFU/ml of L. monocytogenes (isothermal immersion without temperature differential). Water containing L. monocytogenes infiltrated both full slip and clipped cantaloupes through the stems/stem scars and was then distributed along the vascular system in hypodermal mesocarp reaching the calyx area of the fruit. The current study demonstrated that, under experimental conditions, L. monocytogenes can internalize into cantaloupes during immersion in water contaminated by L. monocytogenes, both in the presence and absence of temperature differential, and that temperature differential moderately enhanced the internalization of L. monocytogenes. The incidence and levels of L. monocytogenes internalized in the middle-mesocarp were significantly affected by harvesting technique but not by cantaloupe cultivar. Published by Elsevier B.V.
USDA-ARS?s Scientific Manuscript database
The effects of scalding water temperature and immersion time on impact to poultry processing wastewater (PPW) loading were evaluated following the slaughter of commercially raised broilers. Based on previous research, the hypothesis was that immersion time would have a significant impact on PPW load...
Inactivation of salmonella in shell eggs by hot water immersion and its effect on quality
USDA-ARS?s Scientific Manuscript database
Thermal inactivation kinetics of heat resistant strains of Salmonella Enteritidis in shell eggs processed by hot water immersion were determined, and the effects of the processing on egg quality were evaluated. Shell eggs were inoculated with a composite of heat resistant Salmonella Enteritidis (SE)...
Effect of gender, cadence, and water immersion on ground reaction forces during stationary running.
de Brito Fontana, Heiliane; Haupenthal, Alessandro; Ruschel, Caroline; Hubert, Marcel; Ridehalgh, Colette; Roesler, Helio
2012-05-01
Controlled laboratory study. To analyze the vertical and anteroposterior components of the ground reaction force during stationary running performed in water and on dry land, focusing on the effect of gender, level of immersion, and cadence. Stationary running, as a fundamental component of aquatic rehabilitation and training protocols, is little explored in the literature with regard to biomechanical variables, which makes it difficult to determine and control the mechanical load acting on the individuals. Twenty-two subjects performed 1 minute of stationary running on land, immersed to the hip, and immersed to the chest at 3 different cadences: 90 steps per minute, 110 steps per minute, and 130 steps per minute. Force data were acquired with a force plate, and the variables were vertical peak (Fy), loading rate (LR), anterior peak (Fx anterior), and posterior peak (Fx posterior). Data were normalized to subjects' body weight (BW) and analyzed using repeated-measures analysis of variance. Fy ranged from 0.98 to 2.11 BW, LR ranged from 5.38 to 11.52 BW/s, Fx anterior ranged from 0.07 to 0.14 BW, and Fx posterior ranged from 0.06 to 0.09 BW. The gender factor had no effect on the variables analyzed. A significant interaction between level of immersion and cadence was observed for Fy, Fx anterior, and Fx posterior. On dry land, Fy increased with increasing cadence, whereas in water this effect was seen only between 90 steps per minute and the 2 higher cadences. The higher the level of immersion, the lower the magnitude of Fy. LR was reduced under both water conditions and increased with increasing cadence, regardless of the level of immersion. Ground reaction forces during stationary running are similar between genders. Fy and LR are lower in water, though the values are increased at higher cadences.
Immersion Suit Flotation Testing REACT Report
2016-08-01
wind-generated motion, we used a 75-pound, pyramid anchor , with 20 feet of 3/8 inch mooring chain. As with the ballasted mannequin, the team fully...everything, packed it and shipped it to JMTF Mobile where the team would reassemble the gear for in-water deployment. This included both 75-pound anchors ...first mooring on the ramp, put the tethered buoy in the water, then put the anchor over the side, allowing the chain to run free. Next, the team
Kitchens, Michael; Owens, Barry M
2007-01-01
This study evaluated the effect of carbonated and non-carbonated beverages, bottled and tap water, on the erosive potential of dental enamel with and without fluoride varnish protection. Beverages used in this study included: Coca Cola Classic, Diet Coke, Gatorade sports drink, Red Bull high-energy drink, Starbucks Frappuccino coffee drink, Dasani water (bottled), and tap water (control). Enamel surfaces were coated with Cavity Shield 5% sodium fluoride treatment varnish. Twenty-eight previously extracted human posterior teeth free of hypocalcification and caries were used in this study. The coronal portion of each tooth was removed and then sectioned transverse from the buccal to lingual surface using a diamond coated saw blade. The crown sections were embedded in acrylic resin blocks leaving the enamel surfaces exposed. The enamel surfaces were polished using 600 to 2000 grit abrasive paper and diamond paste. Test specimens were randomly distributed to seven beverage groups and comprised 4 specimens per group. Two specimens per beverage group were treated with a fluoride varnish while 2 specimens did not receive fluoride coating. Surface roughness (profilometer) readings were performed at baseline (prior to fluoride treatment and immersion in the beverage) and again, following immersion for 14 days (24 hours/day). The test beverages were changed daily and the enamel specimens were immersed at 37 degrees C. Surface roughness data was evaluated using multiple factor ANOVA at a significance level of p<0.05. Results showed that Coca-Cola Classic, Gatorade and Red Bull with/without fluoride revealed the highest post-treatment surface roughness measurements. Coca-Cola Classic, Diet Coke, Gatorade, and Red Bull all showed significantly higher post treatment readings than StarBucks coffee, Dasani water, and tap water. Fluoride varnish was not a significant impact factor; however, beverage (type) and exposure time were significant impact variables. Both carbonated and non-carbonated beverages displayed a significant erosive effect on dental enamel; however, fluoride varnish treatments did not demonstrate a significant protective influence on enamel surfaces.
Cold immersion recovery responses in the diabetic foot with neuropathy.
Bharara, Manish; Viswanathan, Vijay; Cobb, Jonathan E
2008-10-01
The aim of this article was to investigate the effectiveness of testing cold immersion recovery responses in the diabetic foot with neuropathy using a contact thermography system based on thermochromic liquid crystals. A total of 81 subjects with no history of diabetic foot ulceration were assigned to neuropathy, non neuropathy and healthy groups. Each group received prior verbal and written description of the test objectives and subsequently underwent a comprehensive foot care examination. The room temperature and humidity were consistently maintained at 24 degrees C and less than 50%, respectively, with air conditioning. The right foot for each subject was located on the measurement platform after cold immersion in water at 18-20 degrees C. Whole-field thermal images of the plantar foot were recorded for 10 minutes. Patients with diabetes with neuropathy show the highest 'delta temperature', that is difference between the temperature after 10-minute recovery period and baseline temperature measured independently at all the three sites tested, that is first metatarsal head (MTH), second MTH and heel. This clinical study showed for the first time the evidence of poor recovery times for the diabetic foot with neuropathy when assessing the foot under load. A temperature deficit (because of poor recovery to baseline temperature) suggests degeneration of thermoreceptors, leading to diminished hypothalamus-mediated activity in the diabetic neuropathic group.
Immersion diuresis without expected suppression of vasopressin
NASA Technical Reports Server (NTRS)
Keil, L. C.; Silver, J. E.; Wong, N.; Spaul, W. A.; Greenleaf, J. E.; Kravik, S. E.
1984-01-01
There is a shift of blood from the lower parts of the body to the thoracic circulation during bed rest, water immersion, and presumably during weightlessness. On earth, this central fluid shift is associated with a profound diuresis. However, the mechanism involved is not yet well understood. The present investigation is concerned with measurements regarding the plasma vasopressin, fluid, electrolyte, and plasma renin activity (PRA) responses in subjects with normal preimmersion plasma vasopressin (PVP) concentration. In the conducted experiments, PRA was suppressed significantly at 30 min of immersion and had declined by 74 percent by the end of the experiment. On the basis of previously obtained results, it appears that sodium excretion during immersion may be independent of aldosterone action. Experimental results indicate that PVP is not suppressed by water immersion in normally hydrated subjects and that other factors may be responsible for the diuresis.
Gibson, William; Moss, Penny; Cheng, Tak Ho; Garnier, Alexandre; Wright, Anthony; Wand, Benedict M
2018-03-01
Many factors interact to influence threat perception and the subsequent experience of pain. This study investigated the effect of observing pain (extrinsic threat) and intrinsic threat of pain to oneself on pressure pain threshold (PPT). Forty socially connected pairs of healthy volunteers were threat-primed and randomly allocated to experimental or control roles. An experimental pain modulation paradigm was applied, with non-nociceptive threat cues used as conditioning stimuli. In substudy 1, the extrinsic threat to the experimental participant was observation of the control partner in pain. The control participant underwent hand immersion in noxious and non-noxious water baths in randomized order. Change in the observing participant's PPT from baseline to mid- and postimmersion was calculated. A significant interaction was found for PPT between conditions and test time (F 2,78 = 24.9, P < .005). PPT increased by 23.6% ± 19.3% between baseline and during hand immersion (F 1,39 = 43.7, P < .005). Substudy 2 investigated threat of imminent pain to self. After a 15-minute break, the experimental participant's PPT was retested ("baseline 2"). Threat was primed by suggestion of whole arm immersion in an icier, larger water bath. PPT was tested immediately before anticipated arm immersion, after which the experiment ended. A significant increase in PPT between "baseline 2" and "pre-immersion" was seen (t = -7.6, P = .005), a pain modulatory effect of 25.8 ± 20.7%. Extrinsic and intrinsic threat of pain, in the absence of any afferent input therefore influences pain modulation. This may need to be considered in studies that use noxious afferent input with populations who show dysfunctional pain modulation. The effect on endogenous analgesia of observing another's pain and of threat of pain to oneself was investigated. Extrinsic as well as intrinsic threat cues, in the absence of any afferent input, increased pain thresholds, suggesting that mere threat of pain may initiate analgesic effects in traditional noxious experimental paradigms. Copyright © 2017 The American Pain Society. Published by Elsevier Inc. All rights reserved.
USDA-ARS?s Scientific Manuscript database
When dried organisms are immersed in water, rapid imbibition may cause severe damage to plasma membranes; in unicellular organisms, such damage is usually lethal. This study investigated effects of pre-immersion moisture levels and immersion temperature on imbibitional damage in three insect pathoge...
Estimation of regional cutaneous cold sensitivity by analysis of the gasping response.
Burke, W E; Mekjavić, I B
1991-11-01
Regional cutaneous sensitivity to cooling was assessed in males by separately immersing four discrete skin regions in cold water (15 degrees C) during head-out immersion. The response measured was gasping at the onset of immersion; the gasping response appears to be the result of a nonthermoregulatory neurogenic drive from cutaneous cold receptors. Subjects of similar body proportions wore a neoprene "dry" suit modified to allow exposure to the water of either the arms, upper torso, lower torso, or legs, while keeping the unexposed skin regions thermoneutral. Each subject was immersed to the sternal notch in all four conditions of partial exposure plus one condition of whole body exposure. The five cold water conditions were matched by control immersions in lukewarm (34 degrees C) water, and trials were randomized. The magnitude of the gasping response was determined by mouth occlusion pressure (P0.1). For each subject, P0.1 values for the 1st min of immersion were integrated, and control trial values, although minimal, were subtracted from their cold water counterpart to account for any gasping due to the experimental design. Results were averaged and showed that the highest P0.1 values were elicited from whole body exposure, followed in descending order by exposures of the upper torso, legs, lower torso, and arms. Correction of the P0.1 response for differences in exposed surface area (A) and cooling stimulus (delta T) between regions gave a cold sensitivity index [CSI, P0.1/(A.delta T)] for each region and showed that the index for the upper torso was significantly higher than that for the arms or legs; no significant difference was observed between the indexes for the upper and lower torso.(ABSTRACT TRUNCATED AT 250 WORDS)
Khomenok, Gennadi A; Hadid, Amir; Preiss-Bloom, Orahn; Yanovich, Ran; Erlich, Tomer; Ron-Tal, Osnat; Peled, Amir; Epstein, Yoram; Moran, Daniel S
2008-09-01
The current study examines the use of hand immersion in cold water to alleviate physiological strain caused by exercising in a hot climate while wearing NBC protective garments. Seventeen heat acclimated subjects wearing a semi-permeable NBC protective garment and a light bulletproof vest were exposed to a 125 min exercise-heat stress (35 degrees C, 50% RH; 5 km/h, 5% incline). The heat stress exposure routine included 5 min rest in the chamber followed by two 50:10 min work-rest cycles. During the control trial (CO), there was no intervention, whilst in the intervention condition the subjects immersed their hands and forearms in a 10 degrees C water bath (HI). The results demonstrated that hand immersion in cold water significantly reduced physiological strain. In the CO exposure during the first and second resting periods, the average rectal temperature (T (re)) practically did not decrease. With hand immersion, the mean (SD) T (re) decreased by 0.45 (0.05 degrees C) and 0.48 degrees C (0.06 degrees C) during the first and second rest periods respectively (P < 0.005). Significant decreases in skin temperature, sweat rate, heart rate, and heat storage was also noted in the HI vs. the CO trials. Tolerance time in the HI exposure were longer than in the CO exposure (only 12 subjects in the CO trial endured the entire heat exposure session, as opposed to all 17 subjects in the HI group). It is concluded that hand immersion in cold water for 10 min is an effective method for decreasing the physiological strain caused by exercising under heat stress while wearing NBC protective garments. The method is convenient, simple, and allows longer working periods in hot or contaminated areas with shorter resting periods.
Influence of Water Solute Exposure on the Chemical Evolution and Rheological Properties of Asphalt.
Pang, Ling; Zhang, Xuemei; Wu, Shaopeng; Ye, Yong; Li, Yuanyuan
2018-06-11
The properties of asphalt pavement are damaged under the effects of moisture. The pH value and salt concentration of water are the key factors that affect the chemical and rheological properties of asphalt during moisture damage. Four kinds of water solutions, including distilled water, an acidic solution, alkaline solution and saline solution were used to investigate the effects of aqueous solute compositions on the chemical and rheological properties of asphalt. Thin-layer chromatography with flame ionization detection (TLC-FID), Fourier transform infrared (FTIR) spectroscopy and dynamic shear rheometer (DSR) were applied to investigate the components, chemistry and rheology characteristics of asphalt specimens before and after water solute exposure. The experimental results show that moisture damage of asphalt is not only associated with an oxidation process between asphalt with oxygen, but it is also highly dependent on some compounds of asphalt dissolving and being removed in the water solutions. In detail, after immersion in water solute, the fraction of saturates, aromatics and resins in asphalt binders decreased, while asphaltenes increased; an increase in the carbonyl and sulphoxide indices, and a decrease in the butadiene index were also found from the FTIR analyzer test. The rheological properties of asphalt are sensitive to water solute immersing. The addition of aqueous solutes causes more serious moisture damage on asphalt binders, with the pH11 solution presenting as the most destructive during water solute exposure.
Surface roughness of orthodontic band cements with different compositions
van de SANDE, Françoise Hélène; da SILVA, Adriana Fernandes; MICHELON, Douver; PIVA, Evandro; CENCI, Maximiliano Sérgio; DEMARCO, Flávio Fernando
2011-01-01
Objectives The present study evaluated comparatively the surface roughness of four orthodontic band cements after storage in various solutions. Material and Methods eight standardized cylinders were made from 4 materials: zinc phosphate cement (ZP), compomer (C), resin-modified glass ionomer cement (RMGIC) and resin cement (RC). Specimens were stored for 24 h in deionized water and immersed in saline (pH 7.0) or 0.1 M lactic acid solution (pH 4.0) for 15 days. Surface roughness readings were taken with a profilometer (Surfcorder SE1200) before and after the storage period. Data were analyzed by two-way ANOVA and Tukey's test (comparison among cements and storage solutions) or paired t-test (comparison before and after the storage period) at 5% significance level. Results The values for average surface roughness were statistically different (p<0.001) among cements at both baseline and after storage. The roughness values of cements in a decreasing order were ZP>RMGIC>C>R (p<0.001). After 15 days, immersion in lactic acid solution resulted in the highest surface roughness for all cements (p<0.05), except for the RC group (p>0.05). Compared to the current threshold (0.2 µm) related to biofilm accumulation, both RC and C remained below the threshold, even after acidic challenge by immersion in lactic acid solution. Conclusions Storage time and immersion in lactic acid solution increased the surface roughness of the majority of the tested cements. RC presented the smoothest surface and it was not influenced by storage conditions. PMID:21625737
Schlagenhauf, Lukas; Kianfar, Bahareh; Buerki-Thurnherr, Tina; Kuo, Yu-Ying; Wichser, Adrian; Nüesch, Frank; Wick, Peter; Wang, Jing
2015-11-28
Weathering processes can influence the surface properties of composites with incorporated nanoparticles. These changes may affect the release behavior of nanoparticles when an abrasion process is applied. Therefore, the influence of two different weathering processes, immersion in water and exposure to UV light, on the properties of abraded particles from a carbon nanotube (CNT)/epoxy nanocomposite was investigated. The investigation included the measurement of the weathering impact on the surface chemistry of the exposed samples, the particle size of abraded particles, the quantity of exposed CNTs in the respirable part of the abraded particles, and the toxicity of abraded particles, measured by in vitro toxicity tests using the THP-1 monocyte-derived macrophages. The results showed that weathering by immersion in water had no influence on the properties of abraded particles. The exposure to UV light caused a degradation of the epoxy on the surface, followed by delamination of an approx. 2.5 μm thick layer. An increased quantity of exposed CNTs in abraded particles was not found; on the contrary, longer UV exposure times decreased the released fraction of CNTs from 0.6% to 0.4%. The toxicity tests revealed that abraded particles from the nanocomposites did not induce additional acute cytotoxic effects compared to particles from the neat epoxy.
Heated Debates: Hot-Water Immersion or Ice Packs as First Aid for Cnidarian Envenomations?
Wilcox, Christie L; Yanagihara, Angel A
2016-04-01
Cnidarian envenomations are an important public health problem, responsible for more deaths than shark attacks annually. For this reason, optimization of first-aid care is essential. According to the published literature, cnidarian venoms and toxins are heat labile at temperatures safe for human application, which supports the use of hot-water immersion of the sting area(s). However, ice packs are often recommended and used by emergency personnel. After conducting a systematic review of the evidence for the use of heat or ice in the treatment of cnidarian envenomations, we conclude that the majority of studies to date support the use of hot-water immersion for pain relief and improved health outcomes.
Water absorption behaviour of hybrid interwoven cellulosic fibre composites
NASA Astrophysics Data System (ADS)
Maslinda, A. B.; Majid, M. S. Abdul; Ridzuan, M. J. M.; Syayuthi, AR. A.
2017-10-01
The present paper investigated the water absorption behaviour of hybrid interwoven cellulosic fibre composites. Hybrid composites consisting of interwoven kenaf/jute and kenaf/hemp yarns were prepared by an infusion manufacturing technique that used epoxy as the polymer matrix. Water absorption test was conducted as elucidated in ASTM D570 standard by immersing the composite samples in tap water at room temperature until reaching their water content saturation point. For each composite type, average from five samples was recorded and the percentage of water uptake against the square root of time was plotted. As the effect of hybridization, the water uptake, diffusion and permeability coefficient of the hybrid composites were lesser than the individual woven composites.
Ventilation-perfusion relationships in the lung during head-out water immersion
NASA Technical Reports Server (NTRS)
Derion, Toniann; Guy, Harold J. B.; Tsukimoto, Koichi; Schaffartzik, Walter; Prediletto, Renato; Poole, David C.; Knight, Douglas R.; Wagner, Peter D.
1992-01-01
Mechanisms of altered pulmonary gas exchange during water immersion were studied in 12 normal males: 6 young (aged 20-29) and 6 older (aged 40-45). It is concluded that, in young subjects with closing volume (CV) less than expiratory reserve volume (ERV), gas exchange was enhanced during immersion, because normal ventilation-perfusion relations were preserved, and by mass balance, the ventilation/O2 uptake changes elevated arterial P(O2). In older males with CV greater than ERV and 52 percent of tidal volume below CV, immersion-induced airways closure during tidal breathing was associated with minimally increased shunt that did not significantly impair gas exchange. It is suggested that airways closure of this degree is of little importance to gas exchange.
Characterization of Thermal and Mechanical Impact on Aluminum Honeycomb Structures
NASA Technical Reports Server (NTRS)
Robinson, Christen M.
2013-01-01
This study supports NASA Kennedy Space Center's research in the area of intelligent thermal management systems and multifunctional thermal systems. This project addresses the evaluation of the mechanical and thermal properties of metallic cellular solid (MCS) materials; those that are lightweight; high strength, tunable, multifunctional and affordable. A portion of the work includes understanding the mechanical properties of honeycomb structured cellular solids upon impact testing under ambient, water-immersed, liquid nitrogen-cooled, and liquid nitrogen-immersed conditions. Additionally, this study will address characterization techniques of the aluminum honeycomb's ability to resist multiple high-rate loadings or impacts in varying environmental conditions, using various techniques for the quantitative and qualitative determination for commercial applicability.
Guimarães, Bruno Martini; Tartari, Talita; Marciano, Marina Angélica; Vivan, Rodrigo Ricci; Mondeli, Rafael Francisco Lia; Camilleri, Josette; Duarte, Marco Antonio Hungaro
2015-06-01
Discoloration of mineral trioxide aggregate (MTA) can be exacerbated by the interaction of the cement with body fluids such as blood. This study aimed to analyze the color alteration, chemical characteristics, and radiopacity of MTA manipulated with 2 different vehicles after immersion in blood or distilled water (DW). MTA mixed with 100% DW or 80% DW/20% propylene glycol (PG) as vehicles were placed into rubber rings and incubated at 37°C and 100% relative humidity until set. Color assessment and scanning electron microscopy/energy-dispersive spectroscopy analysis were performed after setting and repeated after 7, 15, and 30 days after immersion in blood and DW. Statistical analysis for color alteration and radiopacity was performed using nonparametric Kruskal-Wallis and Dunn tests (P < .05). When 80% DW/20% PG was used as the vehicle, significantly lower color alterations were observed for all time periods compared with 100% DW when immersed in blood (P < .05). All surfaces displayed morphologic changes after immersion in both media because of loss of bismuth. A decrease in radiopacity was observed over time in all groups, with a statistically significant difference after 30 days for groups DW immersed in blood and 80% DW/20% immersed in both media (P < .05). The ratio of 80% DW/20% PG as a vehicle for MTA results in a lower color alteration when in contact with blood. Copyright © 2015 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Tian, Kuo; Benson, Craig H.; Tinjum, James M.; ...
2017-06-01
Antioxidant depletion was evaluated in high-density polyethylene (HDPE) geomembrane (GM) coupons immersed in radioactive synthetic leachate (RSL) representative of leachate in low-level radioactive waste (LLW) disposal facilities operated by the U.S. Department of Energy’s environmental restoration programs. Depletion was assessed at four temperatures (25, 50, 70, and 90°C). Comparative tests were conducted with nonradioactive synthetic leachate (NSL) having the same chemistry as RSL, except radionuclides were excluded. Control tests were conducted with deionized (DI) water. One-sided exposure tests were also conducted with the HDPE GM in RSL at 70 and 90°C. Specimens were removed periodically and tested to determine antioxidantmore » depletion, melt flow index (MFI), crystallinity, and stress crack resistance. Standard and high-pressure oxidative induction time (OIT) tests were conducted to measure antioxidant depletion. Antioxidant depletion rates in RSL were only slightly greater than those in NSL, indicating that radionuclides in the LLW leachate had only minor effect on antioxidant depletion. Antioxidant depletion in RSL and NSL occurred 1.1–1.9 times faster than in DI water. Antioxidant depletion in HDPE GMs exposed to RSL and NSL at 90°C was complete after 12 months. MFI decreased systematically after 15 months of immersion, which is indicative of crosslinking due to oxidation. Crystallinity also decreased slightly after 12 months, whereas stress crack resistance (SCR) showed no trend over the immersion period. Arrhenius modeling was used to extrapolate the laboratory data at elevated temperatures to a typical LLWliner at 15°C. Predicted time for antioxidant depletion for a 2-mm-thick HDPE GM in a composite liner in contact with LLW leachate is estimated to be 730 years. The total service life of HDPE GMs in contact with LLWleachate is estimated to be at least 1975 years.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tian, Kuo; Benson, Craig H.; Tinjum, James M.
Antioxidant depletion was evaluated in high-density polyethylene (HDPE) geomembrane (GM) coupons immersed in radioactive synthetic leachate (RSL) representative of leachate in low-level radioactive waste (LLW) disposal facilities operated by the U.S. Department of Energy’s environmental restoration programs. Depletion was assessed at four temperatures (25, 50, 70, and 90°C). Comparative tests were conducted with nonradioactive synthetic leachate (NSL) having the same chemistry as RSL, except radionuclides were excluded. Control tests were conducted with deionized (DI) water. One-sided exposure tests were also conducted with the HDPE GM in RSL at 70 and 90°C. Specimens were removed periodically and tested to determine antioxidantmore » depletion, melt flow index (MFI), crystallinity, and stress crack resistance. Standard and high-pressure oxidative induction time (OIT) tests were conducted to measure antioxidant depletion. Antioxidant depletion rates in RSL were only slightly greater than those in NSL, indicating that radionuclides in the LLW leachate had only minor effect on antioxidant depletion. Antioxidant depletion in RSL and NSL occurred 1.1–1.9 times faster than in DI water. Antioxidant depletion in HDPE GMs exposed to RSL and NSL at 90°C was complete after 12 months. MFI decreased systematically after 15 months of immersion, which is indicative of crosslinking due to oxidation. Crystallinity also decreased slightly after 12 months, whereas stress crack resistance (SCR) showed no trend over the immersion period. Arrhenius modeling was used to extrapolate the laboratory data at elevated temperatures to a typical LLWliner at 15°C. Predicted time for antioxidant depletion for a 2-mm-thick HDPE GM in a composite liner in contact with LLW leachate is estimated to be 730 years. The total service life of HDPE GMs in contact with LLWleachate is estimated to be at least 1975 years.« less
Macdermid, Paul W; Wharton, Josh; Schill, Carina; Fink, Philip W
2017-07-01
The purpose of this study was to compare impact loading, kinematic and physiological responses to three different immersion depths (mid-shin, mid-thigh, and xiphoid process) while running at the same speed on a water based treadmill. Participants (N=8) ran on a water treadmill at three depths for 3min. Tri-axial accelerometers were used to identify running dynamics plus measures associated with impact loading rates, while heart rate data were logged to indicate physiological demand. Participants had greater peak impact accelerations (p<0.01), greater impact loading rates (p<0.0001), greater stride frequency (p<0.05), shorter stride length (p<0.01), and greater rate of acceleration development at toe-off (p<0.0001) for the mid-shin and mid-thigh compared to running immersed to the xiphoid process. Physiological effort determined by heart rate was also significantly less (p<0.0001) when running immersed to the xiphoid process. Water immersed treadmill running above the waistline alters kinematics of gait, reduces variables associated with impact, while decreasing physiological demand compared to depths below the waistline. Copyright © 2017 Elsevier B.V. All rights reserved.
Inherent work suit buoyancy distribution: effects on lifejacket self-righting performance.
Barwood, Martin J; Long, Geoffrey M; Lunt, Heather; Tipton, Michael J
2014-09-01
Accidental immersion in cold water is an occupational risk. Work suits and life jackets (LJ) should work effectively in combination to keep the airway clear of the water (freeboard) and enable self-righting. We hypothesized that inherent buoyancy, in the suit or LJ, would be beneficial for enabling freeboard, but its distribution may influence LJ self-righting. Six participants consented to complete nine immersions. Suits and LJ tested were: flotation suit (FLOAT; 85 N inherent buoyancy); oilskins 1 (OS-1) and 2 (OS-2), both with no inherent buoyancy; LJs (inherent buoyancy/buoyancy after inflation/total buoyancy), LJ-1 50/150/200 N, LJ-2 0/290/290 N, LJ-3 80/190/270 N. Once dressed, the subject entered an immersion pool where uninflated freeboard, self-righting performance, and inflated freeboard were measured. Data were compared using Friedman's test to the 0.05 alpha level. All suits and LJs enabled uninflated and inflated freeboard, but differences were seen between the suits and LJs. Self-righting was achieved on 43 of 54 occasions, irrespective of suit or LJ. On all occasions that self-righting was not achieved, this occurred in an LJ that included inherent buoyancy (11/54 occasions). Of these 11 failures, 8 occurred (73% of occasions) when the FLOAT suit was being worn. LJs that included inherent buoyancy, that are certified as effective on their own, worked less effectively from the perspective of self-righting in combination with a work suit that also included inherent buoyancy. Equipment that is approved for use in the workplace should be tested in combination to ensure adequate performance in an emergency scenario.
Electrodermal Activity Is Sensitive to Cognitive Stress under Water.
Posada-Quintero, Hugo F; Florian, John P; Orjuela-Cañón, Alvaro D; Chon, Ki H
2017-01-01
When divers are at depth in water, the high pressure and low temperature alone can cause severe stress, challenging the human physiological control systems. The addition of cognitive stress, for example during a military mission, exacerbates the challenge. In these conditions, humans are more susceptible to autonomic imbalance. Reliable tools for the assessment of the autonomic nervous system (ANS) could be used as indicators of the relative degree of stress a diver is experiencing, which could reveal heightened risk during a mission. Electrodermal activity (EDA), a measure of the changes in conductance at the skin surface due to sweat production, is considered a promising alternative for the non-invasive assessment of sympathetic control of the ANS. EDA is sensitive to stress of many kinds. Therefore, as a first step, we tested the sensitivity of EDA, in the time and frequency domains, specifically to cognitive stress during water immersion of the subject (albeit with their measurement finger dry for safety). The data from 14 volunteer subjects were used from the experiment. After a 4-min adjustment and baseline period after being immersed in water, subjects underwent the Stroop task, which is known to induce cognitive stress. The time-domain indices of EDA, skin conductance level (SCL) and non-specific skin conductance responses (NS.SCRs), did not change during cognitive stress, compared to baseline measurements. Frequency-domain indices of EDA, EDASymp (based on power spectral analysis) and TVSymp (based on time-frequency analysis), did significantly change during cognitive stress. This leads to the conclusion that EDA, assessed by spectral analysis, is sensitive to cognitive stress in water-immersed subjects, and can potentially be used to detect cognitive stress in divers.
Gagnon, Daniel; Lemire, Bruno B.; Casa, Douglas J.; Kenny, Glen P.
2010-01-01
Abstract Context: Cold-water immersion is recommended for the immediate field treatment of exertional heat stroke. However, concerns exist over potential overcooling of hyperthermic individuals during cold-water immersion. Objective: To evaluate the recommendation that removing previously hyperthermic individuals from a cold-water bath at a rectal temperature (Tre) of 38.6°C would attenuate overcooling. Design: Controlled laboratory study. Setting: University research laboratory. Patients or Other Participants: Participants included 6 men and 4 women (age = 22 ± 3 years, height = 172 ± 10 cm, mass = 67.8 ± 10.7 kg, body fat percentage = 17.1% ± 4.5%, maximum oxygen consumption = 59.3 ± 8.7 mL·kg−1·min−1). Intervention(s): After exercising at an ambient temperature of 40.0°C for 38.5 ± 9.4 minutes, until Tre reached 39.5°C, participants were immersed in a 2.0°C circulated water bath until Tre decreased to either 37.5°C or 38.6°C. Subsequently, participants were removed from the water bath and recovered for 20 minutes at an ambient temperature of 25°C. Main Outcome Measure(s): Rectal and esophageal temperatures were measured continuously during the immersion and recovery periods. Results: Because of the experimental design, the overall time of immersion was greater during the 37.5°C trial (16.6 ± 5.7 minutes) than the 38.6°C trial (8.8 ± 2.6 minutes) (t9 = −4.740, P = .001). During the recovery period after cold-water immersion, both rectal (F1,9 = 50.540, P < .001) and esophageal (F1,6 = 20.365, P = .007) temperatures remained greater in the 38.6°C trial than in the 37.5°C trial. This was evidenced by low points of 36.47°C ± 0.70°C and 37.19°C ± 0.71°C for rectal temperature (t9 = 2.975, P = .016) and of 35.67°C ± 1.27°C and 36.72°C ± 0.95°C for esophageal temperature (t6 = 3.963, P = .007) during the recovery period of the 37.5°C and 38.6°C trials, respectively. Conclusions: Immersion for approximately 9 minutes to a rectal temperature cooling limit of 38.6°C negated any risk associated with overcooling hyperthermic individuals when they were immersed in 2°C water. PMID:20831387
Colavolpe, María Belén; Mejía, Santiago Jaramillo; Albertó, Edgardo
2014-01-01
Trichoderma spp is the cause of the green mold disease in mushroom cultivation production. Many disinfection treatments are commonly applied to lignocellulose substrates to prevent contamination. Mushroom growers are usually worried about the contaminations that may occur after these treatments during handling or spawning. The aim of this paper is to estimate the growth of the green mold Trichoderma sp on lignocellulose substrates after different disinfection treatments to know which of them is more effective to avoid contamination during spawning phase. Three different treatments were assayed: sterilization (121 °C), immersion in hot water (60 and 80 °C), and immersion in alkalinized water. Wheat straw, wheat seeds and Eucalyptus or Populus sawdust were used separately as substrates. After the disinfection treatments, bagged substrates were sprayed with 3 mL of suspension of conidia of Trichoderma sp (10(5) conidia/mL) and then separately spawned with Pleurotus ostreatus or Gymnopilus pampeanus. The growth of Trichoderma sp was evaluated based on a qualitative scale. Trichoderma sp could not grow on non-sterilized substrates. Immersions in hot water treatments and immersion in alkalinized water were also unfavorable treatments for its growth. Co- cultivation with mushrooms favored Trichoderma sp growth. Mushroom cultivation disinfection treatments of lignocellulose substrates influence on the growth of Trichoderma sp when contaminations occur during spawning phase. The immersion in hot water at 60 °C for 30 min or in alkalinized water for 36 h, are treatments which better reduced the contaminations with Trichoderma sp during spawning phase for the cultivation of lignicolous species.
Colavolpe, María Belén; Mejía, Santiago Jaramillo; Albertó, Edgardo
2014-01-01
Trichoderma spp is the cause of the green mold disease in mushroom cultivation production. Many disinfection treatments are commonly applied to lignocellulose substrates to prevent contamination. Mushroom growers are usually worried about the contaminations that may occur after these treatments during handling or spawning. The aim of this paper is to estimate the growth of the green mold Trichoderma sp on lignocellulose substrates after different disinfection treatments to know which of them is more effective to avoid contamination during spawning phase. Three different treatments were assayed: sterilization (121 °C), immersion in hot water (60 and 80 °C), and immersion in alkalinized water. Wheat straw, wheat seeds and Eucalyptus or Populus sawdust were used separately as substrates. After the disinfection treatments, bagged substrates were sprayed with 3 mL of suspension of conidia of Trichoderma sp (105 conidia/mL) and then separately spawned with Pleurotus ostreatus or Gymnopilus pampeanus. The growth of Trichoderma sp was evaluated based on a qualitative scale. Trichoderma sp could not grow on non-sterilized substrates. Immersions in hot water treatments and immersion in alkalinized water were also unfavorable treatments for its growth. Co- cultivation with mushrooms favored Trichoderma sp growth. Mushroom cultivation disinfection treatments of lignocellulose substrates influence on the growth of Trichoderma sp when contaminations occur during spawning phase. The immersion in hot water at 60 °C for 30 min or in alkalinized water for 36 h, are treatments which better reduced the contaminations with Trichoderma sp during spawning phase for the cultivation of lignicolous species. PMID:25763030
Water immersion facility general description, spacecraft design division, crew station branch
NASA Technical Reports Server (NTRS)
1978-01-01
The Water Immersion Facility provides an accurate, safe, neutral buoyancy simulation of zero gravity conditions for development of equipment and procedures, and the training of crews. A detailed description is given of some of the following systems: (1) water tank and support equipment; (2) communications systems; (3) environmental control and liquid cooled garment system (EcS/LCG); (4) closed circuit television system; and (5) medical support system.
NASA Technical Reports Server (NTRS)
Tanimoto, E. Y.
1981-01-01
The periodic testing and evaluation of graphite/epoxy and Kevlar/epoxy material systems after subjecting test specimens to prolonged exposure to several laboratory-controlled environments deemed typical of normal aircraft operations is discussed. It is noted that specimen immersion in water or water-based fluids resulted in the greatest effect on the mechanical properties tested. Also, the environmental fluids showed a tendency to affect Kevlar/epoxy systems at an earlier exposure period than the graphite/epoxy systems. Results also indicate mechanical property strength retention generally being lower for the Kevlar/epoxy systems when compared to the corresponding graphite/epoxy systems in similar environments, after prolonged exposure.
Dehghan, Mojdeh; Vieira Ozorio, Jose Estevam; Chanin, Simon; Tantbirojn, Daranee; Versluis, Antheunis; Garcia-Godoy, Franklin
2017-01-01
Tooth erosion from an acidic insult may be exacerbated by toothbrushing. The purposes of this study were to develop an in vitro methodology to measure enamel loss after brushing immediately following an acidic episode and to investigate the effect of brushing with an anti-erosive toothpaste. The null hypotheses tested were that tooth erosion after brushing with the toothpaste would not be different from brushing with water and that a 1-hour delay before brushing would not reduce tooth erosion. Forty bovine enamel slabs were embedded, polished, and subjected to baseline profilometry. Specimens were bathed in hydrochloric acid for 10 minutes to simulate stomach acid exposure before post-acid profilometry. Toothbrushing was then simulated with a cross-brushing machine and followed by postbrushing profilometry. Group 1 was brushed with water; group 2 was brushed with a 50:50 toothpaste-water slurry; and groups 3 and 4 were immersed in artificial saliva for 1 hour before brushing with water or the toothpaste slurry, respectively. The depth of enamel loss was analyzed and compared using 1-way analysis of variance and post hoc testing (α = 0.05). Greater enamel loss was measured in groups brushed with toothpaste than in groups brushed with water. One-hour immersion in artificial saliva significantly reduced enamel loss when teeth were brushed with water (group 3; P < 0.05) but not with toothpaste (group 4). This study established a protocol for measuring enamel loss resulting from erosion followed by toothbrush abrasion. The results confirmed the abrasive action of toothpaste on acid-softened enamel.
Water absorption characteristic of interlocking compressed earth brick units
NASA Astrophysics Data System (ADS)
Bakar, B. H. Abu; Saari, S.; Surip, N. A.
2017-10-01
This study aims to investigate the water absorption characteristic of interlocking compressed earth brick (ICEB) units. Apart from compressive strength, water absorption is an important property in masonry. This property can affect the quality of the brick itself and the bond strength between the brick and mortar in masonry structures and can result in reducing its strength properties. The units were tested for 24 h water absorption and 5 h boiling water absorption. A total of 170 ICEB units from four ICEB types underwent both tests. For the 24 h water absorption, the ICEB units were dried in the oven for 24 h and then cooled before being weighed. Thereafter, each brick was immersed in water for 24 h and weighed. The same specimens used for the 24 h water absorption test were re-used for the 5 h boiling water absorption test. After completing the 24 h water absorption test, the brick was boiled for 5-hours and weighed. The highest water absorption for the ICEBs in the 24-hour water absorption and 5 h boiling water absorption tests are 15.09% and 17.18%, respectively. The half brick has the highest water absorption (15.87%), whereas the beam brick has the lowest (13.20%). The water absorption of an ICEB unit is higher than that of normal bricks, although the water absorption of the former remains below the maximum rate of the brick water absorption (21%).
Effects of catechin-enriched ion beverage intake on thermoregulatory function in a hot environment.
Nishimura, Rumiko; Nishimura, Naoki; Iwase, Satoshi; Takeshita, Masao; Katashima, Mitsuhiro; Katsuragi, Yoshihisa; Sato, Motohiko
2018-04-23
We examined the effect of intake of a catechin-enriched ion beverage (Cat-I) on the thermoregulatory response in a hot environment. Eight healthy men were exposed to a hot environment for 90 min at an ambient temperature of 35 °C (relative humidity: 75%) combined with lower leg water immersion at 40 °C. At that time, either Cat-I, an ion beverage (Ion), or mineral water (Placebo) was consumed at three points: (1) at the start of lower leg immersion, (2) at 30 min after immersion, and (3) at 60 min after immersion. In all conditions, tympanic temperature (Tty) increased gradually during lower leg water immersion. However, the rate of increase of Tty tended to be suppressed after 30 min. The effect of drinking Cat-I had a limited detection period of approximately 60-70 min, and the rate of sweating was clearly increased with Cat-I compared with Ion and Placebo. Cat-I also tended to decrease the body temperature threshold at which sweating was induced compared with Ion or Placebo. These findings suggest that Cat-I efficiently suppressed the increase of body temperature in a hot environment.
Effect of season on peripheral resistance to localised cold stress
NASA Astrophysics Data System (ADS)
Tanaka, M.; Harimura, Y.; Tochihara, Y.; Yamazaki, S.; Ohnaka, T.; Matsui, J.; Yoshida, K.
1984-03-01
This study was carried out to determine the effect that seasonal changes have on the effect of localised cold stress on peripheral temperatures using the foot immersion method with a cold water bath. The subjects were six males and four females. The data were obtained in April, July, October and January. Skin temperature of the right index finger, the forehead, the arm, the cheek, the second toe and the instep were measured before, during and after the immersion of the feet in water at 15°C for 10 mins, as well as oxygen consumption before immersion of the feet. The average finger temperature was highest during foot immersion in the summer, next highest in the winter, then spring, and the lowest during foot immersion in the autumn. The finger temperatures during the pre-immersion period in the autumn tended to be lower than in other seasons. The finger temperatures during the pre-immersion period affected the temperature change of the finger during the immersion period. The rate of increase of the toe temperature and the foot temperature during post-immersion in the summer and the spring were greater than those in the autumn and winter. Oxygen consumption during the pre-immersion period in the autumn was significantly lower than in the other seasons (p<0.001 or 0.010). Cooling the feet caused no significant changes in the temperatures the cheek, forehead or forearm. The cheek temperature in the summer and autumn was cooler than corresponding temperatures taken in the winter and spring.
Cardiovascular response during submaximal underwater treadmill exercise in stroke patients.
Yoo, Jeehyun; Lim, Kil-Byung; Lee, Hong-Jae; Kwon, Yong-Geol
2014-10-01
To evaluate the cardiovascular response during head-out water immersion, underwater treadmill gait, and land treadmill gait in stroke patients. Ten stroke patients were recruited for underwater and land treadmill gait sessions. Each session was 40 minutes long; 5 minutes for standing rest on land, 5 minutes for standing rest in water or on treadmill, 20 minutes for treadmill walking in water or on land, 5 minutes for standing rest in water or on treadmill, and 5 minutes for standing rest on land. Blood pressure (BP) and heart rate (HR) were measured during each session. In order to estimate the cardiovascular workload and myocardial oxygen demand, the rate pressure product (RPP) value was calculated by multiplying systolic BP (SBP) by HR. SBP, DBP, mean BP (mBP), and RPP decreased significantly after water immersion, but HR was unchanged. During underwater and land treadmill gait, SBP, mBP, DBP, RPP, and HR increased. However, the mean maximum increases in BP, HR and RPP of underwater treadmill walking were significantly lower than that of land treadmill walking. Stroke patients showed different cardiovascular responses during water immersion and underwater gait as opposed to standing and treadmill-walking on land. Water immersion and aquatic treadmill gait may reduce the workload of the cardiovascular system. This study suggested that underwater treadmill may be a safe and useful option for cardiovascular fitness and early ambulation in stroke rehabilitation.
Effect of fluoride sodium mouthwash solutions on cpTI: evaluation of physicochemical properties.
Toniollo, Marcelo Bighetti; Galo, Rodrigo; Macedo, Ana Paula; Rodrigues, Renata Cristina Silveira; Ribeiro, Ricardo Faria; Mattos, Maria da Gloria Chiarello de
2012-01-01
The effects of fluoride, which is present in different oral hygiene products, deserve more investigation because little is known about their impact on the surface of titanium, which is largely used in Implantology. This study evaluated the surface of commercially pure titanium (cpTi) after exposure to different concentrations of sodium fluoride (NaF). The hypothesis tested in this study was that different concentrations of NaF applied at different time intervals can affect the titanium surface in different ways. The treatments resulted in the following groups: GA (control): immersion in distilled water; GB: immersion in 0.05% NaF for 3 min daily; GC: immersion in 0.2% NaF for 3 min daily; GD: immersion in 0.05% NaF for 3 min every 2 weeks; and GE: immersion in 0.2% NaF for 3 min every 2 weeks. The experiment lasted 60 days. Roughness was measured initially and every 15 days subsequently up to 60 days. After 60 days, corrosion analysis and anodic polarization were done. The samples were examined by scanning electron microscopy (SEM). The roughness data were analyzed by ANOVA and there was no significant difference among groups and among time intervals. The corrosion data (i(corr)) were analyzed by the Mann-Whitney test, and significant differences were found between GA and GC, GB and GC, GC and GD, GC and GE. SEM micrographs showed that the titanium surface exposed to NaF presented corrosion that varied with the different concentrations. This study suggests that the use of 0.05% NaF solution on cpTi is safe, whereas the 0.2% NaF solution should be carefully evaluated with regard to its daily use.
Microbial contamination and disinfection methods of pacifiers.
Nelson-Filho, Paulo; Louvain, Márcia Costa; Macari, Soraia; Lucisano, Marília Pacífico; Silva, Raquel Assed Bezerra da; Queiroz, Alexandra Mussolino de; Gaton-Hernández, Patrícia; Silva, Léa Assed Bezerra da
2015-10-01
To evaluate the microbial contamination of pacifiers by Mutans Streptococci(MS) and the efficacy of different methods for their disinfection. Twenty-eight children were assigned to a 4-stage changeover system with a 1-week interval. In each stage, children received a new pacifier and the parents were instructed to maintain their normal habits for 1 week. After this time, the pacifiers were subjected to the following 4 disinfection methods: spraying with 0.12% chlorhexidine solution, Brushtox or sterile tap water, and immersion in boiling tap water for 15 minutes. Microbiological culture for MS and Scanning Electron Microscopy (SEM) were performed. The results were analyzed statistically by Friedman's non-parametric test (a=0.05). The 0.12% chlorhexidine spray was statistically similar to the boiling water (p>0.05) and more effective than the Brushtox spray and control (p<0.05). The analysis of SEM showed the formation of a cariogenic biofilm in all groups with positive culture. Pacifiers become contaminated by MS after their use by children and should be disinfected routinely. Spraying with a 0.12% chlorhexidine solution and immersion in boiling water promoted better disinfection of the pacifiers compared with a commercial antiseptic toothbrush cleanser (Brushtox).
NASA Astrophysics Data System (ADS)
Wang, Jian-Neng; Jan, Chen-Han; Tang, Jaw-Luen; Wu, Wei-Te; Chen, Der-Cheng; Chen, Chien-Hsing; Syu, Jial-Yan; Luo, Ching-Ying
2011-12-01
This paper presents the development and assessment of a liquid level sensor using long-period fiber grating (LPFG) technology and Shewhart control charts. The 22-mm LPFGs were fabricated with the point-by-point CO2 laser engraving method. This sensor was designed in such a way that it could be moved up and down with a position controller. The experimental section covered LPFG position sensing test, liquid level detection capacity and reliability measurements, and sensing resolution evaluation. LPFG position sensing test was studied and confirmed by the resonance wavelength shifts which were significantly generated when 75% of the LPFG was immersed in water. There were ten groups of different liquid level capacity testing and each group underwent ten repeated measurements. Based on Shewhart control charts including an X-bar chart, s chart, and R chart, the results showed all measurands within the upper and lower control limits. This sensor was reliable and the liquid level could be measured at least 1000 mm. The transmission loss versus the percent of immersion of the LPFG sensor for water and green tea was used to study the sensing resolution. The findings show the LPFG-based liquid sensor had at least 1000-mm level measurement capacity and about 2-mm resolution.
Correlation of Wissler Human Thermal Model Blood Flow and Shiver Algorithms
NASA Technical Reports Server (NTRS)
Bue, Grant; Makinen, Janice; Cognata, Thomas
2010-01-01
The Wissler Human Thermal Model (WHTM) is a thermal math model of the human body that has been widely used to predict the human thermoregulatory response to a variety of cold and hot environments. The model has been shown to predict core temperature and skin temperatures higher and lower, respectively, than in tests of subjects in crew escape suit working in a controlled hot environments. Conversely the model predicts core temperature and skin temperatures lower and higher, respectively, than in tests of lightly clad subjects immersed in cold water conditions. The blood flow algorithms of the model has been investigated to allow for more and less flow, respectively, for the cold and hot case. These changes in the model have yielded better correlation of skin and core temperatures in the cold and hot cases. The algorithm for onset of shiver did not need to be modified to achieve good agreement in cold immersion simulations
Ethanol Postpolymerization Treatment for Improving the Biocompatibility of Acrylic Reline Resins
Neves, Cristina B.; Lopes, Luís P.; Ferrão, Helena F.; Miranda, Joana P.; Castro, Matilde F.; Bettencourt, Ana F.
2013-01-01
Objective. To evaluate the effect of postpolymerization treatment based on ethanol-aqueous solutions on the residual monomer (RM) content, flexural strength, microhardness, and cytotoxicity of hard chairside reline resins (Kooliner, Ufi Gel Hard). Methods. After polymerization, specimens were immersed in water, 20%, 50%, or 70% ethanol solutions at 23°C or 55°C for 10 minutes. Controls were left untreated. HPLC was used for the determination of RM content. Specimens were submitted to Vickers microhardness and 3-point loading flexural strength tests. Cytotoxicity of resin eluates was determined on human fibroblasts by assessing cellular mitochondrial function and lactate dehydrogenase release. Results. Higher concentrations of ethanol promoted lower RM content at 55°C in both materials. The mechanical properties were maintained after 50% and 20% ethanol treatments in Kooliner and Ufi Gel Hard, respectively. Specimens submitted to those treatments showed significant reduction on cytotoxicity compared to immersion in hot water, the treatment of choice in the recent literature. Significance. Immersion of relined dentures in specific ethanol solutions at 55°C for 10 minutes can be considered an effective postpolymerization treatment contributing to increase materials biocompatibility. The proposed protocol is expeditious and easy to achieve with simple equipment in a dental office. PMID:23971038
Yamamoto, S; Han, L; Noiri, Y; Okiji, T
2017-12-01
To evaluate the Ca 2+ -releasing, alkalizing and apatite-like surface precipitate-forming abilities of a prototype tricalcium silicate cement, which was mainly composed of synthetically prepared tricalcium silicate and zirconium oxide radiopacifier. The prototype tricalcium silicate cement, white ProRoot MTA (WMTA) and TheraCal LC (a light-cured resin-modified calcium silicate-filled material) were examined. The chemical compositions were analysed with a wavelength-dispersive X-ray spectroscopy electron probe microanalyser with an image observation function (SEM-EPMA). The pH and Ca 2+ concentrations of water in which the set materials had been immersed were measured, and the latter was assessed with the EDTA titration method. The surface precipitates formed on the materials immersed in phosphate-buffered saline (PBS) were analysed with SEM-EPMA and X-ray diffraction (XRD). Kruskal-Wallis tests followed by Mann-Whitney U-test with Bonferroni correction were used for statistical analysis (α = 0.05). The prototype cement contained Ca, Si and Zr as major elemental constituents, whereas it did not contain some metal elements that were detected in the other materials. The Ca 2+ concentrations and pH of the immersion water samples exhibited the following order: WMTA = prototype cement > TheraCal LC (P < 0.05). All three materials produced Ca- and P-containing surface precipitates after PBS immersion, and the precipitates produced by TheraCal LC displayed lower Ca/P ratios than those formed by the other materials. XRD peaks corresponding to hydroxyapatite were detected in the precipitates produced by the prototype cement and WMTA. The prototype tricalcium silicate cement exhibited similar Ca 2+ -releasing, alkalizing and apatite-like precipitate-forming abilities to WMTA. The Ca 2+ -releasing, alkalizing and apatite-like precipitate-forming abilities of TheraCal LC were lower than those of the other materials. © 2016 International Endodontic Journal. Published by John Wiley & Sons Ltd.
Do drowning and anoxia kill head lice?
Candy, Kerdalidec; Brun, Sophie; Nicolas, Patrick; Durand, Rémy; Charrel, Remi N; Izri, Arezki
2018-01-01
Chemical, physical, and mechanical methods are used to control human lice. Attempts have been made to eradicate head lice Pediculus humanus capitis by hot air, soaking in various fluids or asphyxiation using occlusive treatments. In this study, we assessed the maximum time that head lice can survive anoxia (oxygen deprivation) and their ability to survive prolonged water immersion. We also observed the ingress of fluids across louse tracheae and spiracle characteristics contrasting with those described in the literature. We showed that 100% of lice can withstand 8 h of anoxia and 12.2% survived 14 h of anoxia; survival was 48.9% in the untreated control group at 14 h. However, all lice had died following 16 h of anoxia. In contrast, the survival rate of water-immersed lice was significantly higher when compared with non-immersed lice after 6 h (100% vs. 76.6%, p = 0.0037), and 24 h (50.9% vs. 15.9%, p = 0.0003). Although water-immersed lice did not close their spiracles, water did not penetrate into the respiratory system. In contrast, immersion in colored dimeticone/cyclomethicone or colored ethanol resulted in penetration through the spiracles and spreading to the entire respiratory system within 30 min, leading to death in 100% of the lice. © K. Candy et al., published by EDP Sciences, 2018.
Heated Debates: Hot-Water Immersion or Ice Packs as First Aid for Cnidarian Envenomations?
Wilcox, Christie L.; Yanagihara, Angel A.
2016-01-01
Cnidarian envenomations are an important public health problem, responsible for more deaths than shark attacks annually. For this reason, optimization of first-aid care is essential. According to the published literature, cnidarian venoms and toxins are heat labile at temperatures safe for human application, which supports the use of hot-water immersion of the sting area(s). However, ice packs are often recommended and used by emergency personnel. After conducting a systematic review of the evidence for the use of heat or ice in the treatment of cnidarian envenomations, we conclude that the majority of studies to date support the use of hot-water immersion for pain relief and improved health outcomes. PMID:27043628
Cobo Molinos, Antonio; Abriouel, Hikmate; Ben Omar, Nabil; Valdivia, Eva; Lucas López, Rosario; Maqueda, Mercedes; Cañamero, Magdalena Martínez; Gálvez, Antonio
2005-01-01
The effect of immersion solutions containing enterocin AS-48 alone or in combination with chemical preservatives on survival and proliferation of Listeria monocytogenes CECT 4032 inoculated on fresh alfalfa sprouts, soybean sprouts, and green asparagus was tested. Immersion treatments (5 min at room temperature) with AS-48 solutions (25 μg/ml) reduced listeria counts of artificially contaminated alfalfa and soybean sprouts by approximately 2.0 to 2.4 log CFU/g compared to a control immersion treatment in distilled water. The same bacteriocin immersion treatment applied on green asparagus had a very limited effect. During storage of vegetable samples treated with immersion solutions of 12.5 and 25 μg of AS-48/ml, viable listeria counts were reduced below detection limits at days 1 to 7 for alfalfa and soybean sprouts at 6 and 15°C, as well as green asparagus at 15°C. Only a limited inhibition of listeria proliferation was detected during storage of bacteriocin-treated alfalfa sprouts and green asparagus at 22°C. Treatment with solutions containing AS-48 plus lactic acid, sodium lactate, sodium nitrite, sodium nitrate, trisodium phosphate, trisodium trimetaphosphate, sodium thiosulphate, n-propyl p-hydroxybenzoate, p-hydoxybenzoic acid methyl ester, hexadecylpyridinium chloride, peracetic acid, or sodium hypochlorite reduced viable counts of listeria below detection limits (by approximately 2.6 to 2.7 log CFU/g) upon application of the immersion treatment and/or further storage for 24 h, depending of the chemical preservative concentration. Significant increases of antimicrobial activity were also detected for AS-48 plus potassium permanganate and in some combinations with acetic acid, citric acid, sodium propionate, and potassium sorbate. PMID:16332751
Alberton Da Silva, Victória; Alberton Da Silva, Simone; Pecho, Oscar E; Bacchi, Atais
2018-06-19
The aim of this study was to evaluate the color stability of two resin-based composites photo-activated by two light curing units (LCU) with different irradiances. Hundred disc-shaped specimens (2-mm thick) of a nanofilled (FZ- Filtek TM Z350 XT, 3M ESPE) and a microhybrid (ED-Empress ® Direct, Ivoclar Vivadent) composites were photo-activated with two LCU: Valo ® Cordless, Ultradent (VA-1800 mW/cm 2 ) or Radii-cal, SDI (RA-900 mW/cm 2 ). Samples (n = 5) were immersed during 12 days in distilled water (WT), orange juice (OJ), red wine (RW), coffee (CF), or Brazilian tea (BT). CIELAB coordinates were obtained using a spectrophotometer (Easyshade 4.0, Vita Zahnfabrik) before (T 0 ) and after (T 1 ) immersion. CIEDE2000 color difference (ΔE 00 ) and whiteness index for dentistry (WI D ) were calculated. Data was analyzed by two-way ANOVA and Tukey's test (α = 0.05%). FZ light-activated by VA showed higher L* and WI D values (T 0 ) and lower ΔE 00 values after immersion in WT, OJ, and RW. However, there was no effect of both factors on ΔE 00 when samples were immersed in BT and CF. ED light-activated by RA showed significant higher C* values (p ≤ .05). The nanofilled composite photo-activated with higher irradiance showed greater L* and WI D values and better color stability. However, all samples immersed in colored beverages showed ΔE 00 values above the acceptability threshold. Initial color of resin-based composites can change after immersion in staining beverages. However, the best color stability was obtained by the nanocomposite photo-activated by a light-curing unit of higher irradiance. © 2018 Wiley Periodicals, Inc.
Fernandes, Flavio H C N; Orsi, Iara A; Villabona, Camilo A
2013-03-01
This study evaluated the surface roughness (Ra) and color stability of acrylic resin colors (Lucitone 550, QC-20 and Vipi-Wave) used for fabricating bases for complete, removable dentures, overdentures and prosthetic protocol after immersion in chemical disinfectants (1% sodium hypochlorite and 2% peracetic acid) for 30 and 60 minutes. Sixty specimens were made of each commercial brand of resin composite, and divided into 2 groups according to the chemical disinfectants. Specimens had undergone the finishing and polishing procedures, the initial color and roughness measurements were taken (t=0), and after this, ten test specimens of each commercial brand of resin composite were immersed in sodium hypochlorite and ten in peracetic acid, for 30 and 60 minutes, with measurements being taken after each immersion period. These data were submitted to statistical analysis. There was evidence of an increase in Ra after 30 minutes immersion in the disinfectants in all the resins, with QC-20 presenting the highest Ra values, and Vipi-Wave the lowest. After 60 minutes immersion in the disinfectants all the resins presented statistically significant color alteration. Disinfection with 1% sodium hypochlorite and peracetic acid altered the properties of roughness and color of the resins. © 2012 The Gerodontology Society and John Wiley & Sons A/S.
Influence of ozone and paracetic acid disinfection on adhesion of resilient liners to acrylic resin.
Ekren, Orhun; Ozkomur, Ahmet
2016-08-01
The aim of this study was to evaluate the effect of paracetic acid (PAA) and ozone disinfection on the tensile bond strength (TBS) of silicone-based resilient liners to acrylic resins. One hundred and twenty dumbbell shaped heat-polymerized acrylic resins were prepared. From the mid segment of the specimens, 3 mm of acrylic were grinded off and separated parts were reattached by resilient liners. The specimens were divided into 2 control (control1, control7) and 4 test groups of PAA and ozone disinfection (PAA1, PAA7, ozone1 and ozone7; n=10). While control groups were immersed in distilled water for 10 min (control1) and 7 days (control7), test groups were subjected to PAA (16 g/L) or ozone rich water (4 mg/L) for 1 cycle (10 min for PAA and 60 min for ozone) per day for 7 days prior to tensile tests. Measurements of the TBS were analyzed using 3-way ANOVA and Tukey's HSD test. Adhesive strength of Mollosil decreased significantly by application of ozone disinfection. PAA disinfection had no negative effect on the TBS values of Mollosil and Molloplast B to acrylic resin. Single application of ozone disinfection did not have any negative effect on TBS values of Molloplast B, but prolonged exposure to ozone decreased its adhesive strength. The adhesion of resilient liners to acrylic was not adversely affected by PAA disinfection. Immersion in ozonated water significantly decreased TBS of Mollosil. Prolonged exposure to ozone negatively affects adhesion of Molloplast B to denture base materials.
Permeation Properties and Pore Structure of Surface Layer of Fly Ash Concrete
Liu, Jun; Qiu, Qiwen; Xing, Feng; Pan, Dong
2014-01-01
This paper presents an experimental study on the nature of permeation properties and pore structure of concrete surface layers containing fly ash. Concretes containing different dosages of fly ash as a replacement for cement (15% and 30% by weight of total cement materials, respectively) were investigated. Concrete without any fly ash added was also employed as the reference specimen. Laboratory tests were conducted to determine the surface layer properties of concrete including chloride transport, apparent water permeability and pore structure. The results demonstrate that incorporation of fly ash, for the early test period, promotes the chloride ingress at the surface layer of concrete but substituting proportions of fly ash may have little impact on it. With the process of chloride immersion, the chloride concentration at the surface layer of concrete with or without fly ash was found to be nearly the same. In addition, it is suggested that the water permeability at the concrete surface area is closely related to the fly ash contents as well as the chloride exposure time. Pore structure was characterized by means of mercury intrusion porosimetry (MIP) test and the scanning electron microscopy (SEM) images. The modification of pore structure of concrete submersed in distilled water is determined by the pozzolanic reaction of fly ash and the calcium leaching effect. The pozzolanic reaction was more dominant at the immersion time of 180 days while the calcium leaching effect became more evident after 270 days. PMID:28788677
Traynor, Robyn; MacDermid, Joy C
2008-09-01
Intolerance to the cold is common following peripheral nerve injury and surgery of the upper extremity. Despite its prevalence, the exact pathophysiology and natural history of this condition are not well understood. Subjective, self-report questionnaires have been created and validated as reliable measures of post-traumatic cold intolerance. The difficulty currently lies in assigning an objective measure to this predominantly subjective phenomenon. The present study evaluated the test-retest reliability of a proposed objective measure of cold intolerance, the Immersion in Cold-water Evaluation (ICE), and its correlation with subjective measures in healthy control subjects. Two age groups were also compared to investigate the effect of age on cold intolerance and temperature recovery. On two separate testing days, subjects completed three health-related questionnaires and submersed their dominant hands in cold water. The temperature of their second and fifth digits was monitored during recovery. Both the objective cold-provocation testing and the subjective self-report questionnaires were highly reliable albeit not significantly correlated. No significant temperature recovery trend was noted between the age groups. Post-traumatic cold intolerance is postulated to have both a vascular and neural etiology among other contributing causes. The protocol studied here was centered predominantly on the former etiology, examining peripheral blood flow and associated temperature recovery. This study established ICE as a reliable means to objectively measure cold response, supplementing information provided by previously validated self-report methods.
Cadoni, Sergio; Falt, Přemysl; Rondonotti, Emanuele; Radaelli, Franco; Fojtik, Petr; Gallittu, Paolo; Liggi, Mauro; Amato, Arnaldo; Paggi, Silvia; Smajstrla, Vit; Urban, Ondřej; Erriu, Matteo; Koo, Malcolm; Leung, Felix W
2017-05-01
Background and study aims Single-center studies, which were retrospective and/or involved unblinded colonoscopists, have suggested that water exchange, but not water immersion, compared with air insufflation significantly increases the adenoma detection rate (ADR), particularly in the proximal and right colon. Head-to-head comparison of the three techniques with ADR as primary outcome and blinded colonoscopists has not been reported to date. In a randomized controlled trial with blinded colonoscopists, we aimed to evaluate the impact of the three insertion techniques on ADR. Patients and methods A total of 1224 patients aged 50 - 70 years (672 males) and undergoing screening colonoscopy were randomized 1:1:1 to water exchange, water immersion, or air insufflation. Split-dose bowel preparation was adopted to optimize colon cleansing. After the cecum had been reached, a second colonoscopist who was blinded to the insertion technique performed the withdrawal. The primary outcome was overall ADR according to the three insertion techniques (water exchange, water immersion, and air insufflation). Secondary outcomes were other pertinent overall and right colon procedure-related measures. Results Baseline characteristics of the three groups were comparable. Compared with air insufflation, water exchange achieved a significantly higher overall ADR (49.3 %, 95 % confidence interval [CI] 44.3 % - 54.2 % vs. 40.4 % 95 %CI 35.6 % - 45.3 %; P = 0.03); water exchange showed comparable overall ADR vs. water immersion (43.4 %, 95 %CI 38.5 % - 48.3 %; P = 0.28). In the right colon, water exchange achieved a higher ADR than air insufflation (24.0 %, 95 %CI 20.0 % - 28.5 % vs. 16.9 %, 95 %CI 13.4 % - 20.9 %; P = 0.04) and a higher advanced ADR (6.1 %, 95 %CI 4.0 % - 9.0 % vs. 2.5 %, 95 %CI 1.2 % - 4.6 %; P = 0.03). Compared with air insufflation, the mean number of adenomas per procedure was significantly higher with water exchange ( P = 0.04). Water exchange achieved the highest cleanliness scores (overall and in the right colon). These variables were comparable between water immersion and air insufflation. Conclusions The design with blinded observers strengthens the validity of the observation that water exchange, but not water immersion, can achieve significantly higher adenoma detection than air insufflation. Based on this evidence, the use of water exchange should be encouraged.Trial registered at ClinicalTrials.gov (NCT02041507). © Georg Thieme Verlag KG Stuttgart · New York.
Brophy-Williams, Ned; Landers, Grant; Wallman, Karen
2011-01-01
The purpose of the study was to determine the effects of cold water immersion (CWI) performed immediately or 3 h after a high intensity interval exercise session (HIIS) on next-day exercise performance. Eight male athletes performed three HIIS at 90%VO2max velocity followed by either a passive recovery (CON), CWI performed immediately post-exercise (CWI(0)) or CWI performed 3 h post-exercise (CWI(3)). Recovery trials were performed in a counter balanced manner. Participants then returned 24 h later and completed a muscle soreness and a totally quality recovery perception (TQRP) questionnaire, which was then followed by the Yoyo Intermittent Recovery Test [level 1] (YRT). Venous blood samples were collected pre-HIIS and pre-YRT to determine C-Reactive Protein (CRP) levels. Significantly more shuttles were performed during the YRT following CWI(0) compared to the CON trial (p=0.017, ES = 0. 8), while differences between the CWI(3) and the CON trials approached significance (p = 0.058, ES = 0.5). Performance on the YRT between the CWI(0) and CWI(3) trials were similar (p = 0.147, ES = 0. 3). Qualitative analyses demonstrated a 98% and 92% likely beneficial effect of CWI(0) and CWI(3) on next day performance, compared to CON, respectively, while CWI(0) resulted in a 79% likely benefit when compared to CWI(3). CRP values were significantly lower pre-YRT, compared to baseline, following CWI(0) (p = 0.0.36) and CWI(3) (p = 0.045), but were similar for CON (p = 0.157). Muscle soreness scores were similar between trials (p = 1.10), while TQRP scores were significantly lower for CON compared to CWI(0) (p = 0.002 ) and CWI(3) (p = 0.024). Immediate CWI resulted in superior next-day YRT performance compared to CON, while delayed (3 h) CWI was also likely to be beneficial. Qualitative analyses suggested that CWI(0) resulted in better performance than CWI(3). These results are important for athletes who do not have immediate access to CWI following exercise. Key pointsPerformance of cold water immersion as a recovery procedure following exercise is better than performing no recovery procedureAthletes, coaches and sport trainers should implement cold water immersion post-exercise irrespective of the time of administration.Where possible, cold water immersion should be performed immediately post-exercise to gain maximal recovery benefits.
Crampton, D; Egaña, M; Donne, B; Warmington, S A
2014-08-01
Sprint (high-intensity) exercise performance is reduced when immediately preceded by cold water immersion (CWI). We aimed to investigate whether this performance effect could be attenuated by combining an active recovery (arm exercise) with hip-level CWI, and whether this attenuation may be related to an effect on core temperature (Tcore ). Participants (n = 8) completed three Wingate tests before (Ex1) and after (Ex2) four different 30-min recovery interventions: CWI at 15 °C (CW15), arm exercise during CWI at 15 °C (CW15+AE), arm exercise during thermoneutral immersion at 34 °C (TW34+AE) and non-immersed arm exercise (AE). After AE and TW34+AE, performance during Ex2 was not different from Ex1; while after CW15+AE and CW15, performance was reduced by 4.9% and 7.6%, respectively. Arm exercise maintained Tcore during recovery in CW15+AE, while it declined to a larger extent upon commencement of Ex2 (-0.9 °C) when compared with CW15 (-0.6 °C). This suggests similar leg muscle cooling during recovery in CW15 and CW15+AE. Without any other significant effects (e.g., on blood lactate), these data suggest that the improvement in sprint performance following an active CWI recovery, over CWI alone, may be related to maintained Tcore and its effect on neurophysiological mechanisms that drive muscle activation, but not by reduced muscle cooling. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Effects of menthol application on the skin during prolonged immersion in cool and cold water.
Botonis, P G; Kounalakis, S N; Cherouveim, E D; Koskolou, M D; Geladas, N D
2018-03-01
The aim of the study was to compare the effect of skin surface menthol application on rectal temperature (Tre) during prolonged immersion in cool and cold water. We hypothesized that menthol application would lead to a slower Tre decline due to the reduced heat loss as a consequence of the menthol-induced vasoconstriction and that this effect would be attenuated during cold-water immersion. Six male subjects were immersed for 55 minutes in stirred cool (24°C) or cold (14°C) water immediately after attaining a Tre of 38°C by cycling at 60% of maximum heart rate on two occasions: without (ΝM) and with (M) whole-body skin application of menthol cream. Tre, the proximal-distal skin temperature gradient, and oxygen uptake were continuously measured. ANOVA with repeated measures was employed to detect differences among variables. Significance level was set at 0.05. The area under the curve for Tre was calculated and was greater in 24°C M (-1.81 ± 8.22 a.u) compared to 24°C NM (-27.09 ± 19.09 a.u., P = .03, r = .90), 14°C NM (-18.08 ± 10.85 a.u., P = .03, r = .90), and 14°C M (-11.71 ± 12.58 a.u, P = .05, r = .81). In cool water, oxygen uptake and local vasoconstriction were increased (P ≤ .05) by 39 ± 25% and 56 ± 37%, respectively, with menthol compared to ΝM, while no differences were observed in cold water. Menthol application on the skin before prolonged immersion reduces heat loss resulting in a blunted Tre decline. However, such a response is less obvious at 14°C water immersion, possibly because high-threshold cold-sensitive fibers are already maximally recruited and the majority of cold receptors saturated. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Effect of mouthwash and accelerated aging on the color stability of esthetic restorative materials.
Lee, Y K; El Zawahry, M; Noaman, K M; Powers, J M
2000-06-01
To evaluate the color stability of esthetic restorative materials after immersion in mouthwashes and accelerated aging. Compomers and resin-based composites (RBC) were measured at baseline and repeatedly after immersion in three kinds of mouthwash (Listerine, Peridex, Rembrandt Age Defying) for 24 hrs and 7 days, and after aging for 150 kJ/m2. Color was measured according to CIE L*a*b* color scale on a reflection spectrophotometer. After immersion for 7 days, the mouthwash groups did not produce significantly higher color changes than the distilled water group, except with some mouthwashes used with Tetric-Ceram. After immersion for 7 days and aging for 150 kJ/m2, the mouthwash groups did not produce significantly higher color changes than the distilled water group. Aging in weathering chamber produced color change (deltaE*) of 1.1-3.9, which was mainly influenced by the material. With some exceptions, the color changes from immersion of the RBCs and compomers in mouthwashes were not perceptible (deltaE*<3.3).
Influence of cold-water immersion on limb and cutaneous blood flow after exercise.
Mawhinney, Chris; Jones, Helen; Joo, Chang Hwa; Low, David A; Green, Daniel J; Gregson, Warren
2013-12-01
This study aimed to determine the influence of cold (8°C) and cool (22°C) water immersion on femoral artery and cutaneous blood flow after exercise. Twelve men completed a continuous cycle exercise protocol at 70% peak oxygen uptake until a core temperature of 38°C was attained. Subjects were then immersed semireclined into 8°C or 22°C water to the iliac crest for 10 min or rested. Rectal and thigh skin temperature, deep and superficial muscle temperature, thigh and calf skin blood flow (laser Doppler flowmetry), and superficial femoral artery blood flow (duplex ultrasound) were measured before and up to 30 min after immersion. Indices of vascular conductance were calculated (flux and blood flow/mean arterial pressure). Reductions in rectal temperature were similar (0.6°C-0.7°C) in all three trials (P = 0.38). The mean ± SD thigh skin temperature during recovery was 25.4°C ± 3.8°C in the 8°C trial, which was lower than the 28.2°C ± 1.4°C and 33.78°C ± 1.0°C in the 22°C and control trials, respectively (P < 0.001). Recovery muscle temperature was also lowest in the 8°C trial (P < 0.01). Femoral artery conductance was similar after immersion in both cooling conditions and was lower (∼55%) compared with the control condition 30 min after immersion (P < 0.01). Similarly, there was greater thigh (P < 0.01) and calf (P < 0.05) cutaneous vasoconstriction during and after immersion in both cooling conditions relative to the control condition. Colder water temperatures may be more effective in the treatment of exercise-induced muscle damage and injury rehabilitation by virtue of greater reductions in muscle temperature and not muscle blood flow.
Thermal comfort following immersion.
Guéritée, Julien; Redortier, Bernard; House, James R; Tipton, Michael J
2015-02-01
Unlike thermal comfort in air, little research has been undertaken exploring thermal comfort around water sports. We investigated the impact of swimming and cooling in air after swimming on thermal comfort. After 10 min of swimming-and-resting cycles in 28°C water, volunteers wearing two types of garments or in swim briefs, faced winds in 24°C air, at rest or when stepping. Thermal comfort was significantly higher during swimming than resting. Post-immersion, following maximum discomfort, in 45 of 65 tests thermal comfort improved although mean skin temperature was still cooling (0.26 [SD 0.19] °C·min(-1) - max was 0.89°C·min(-1)). When thermal comfort was re-established mean skin temperature was lower than at maximal discomfort in 39 of 54 tests (0.81 [SD 0.58] °C - max difference was 2.68°C). The reduction in thermal discomfort in this scenario could be due to the adaptation of thermoreceptors, or to reductions in cooling rates to levels where discomfort was less stimulated. The relief from the recent discomfort may explain why, later, thermal comfort returned to initial levels in spite of poorer thermal profiles. Copyright © 2014 Elsevier Inc. All rights reserved.
Hypothermic general cold adaptation induced by local cold acclimation.
Savourey, G; Barnavol, B; Caravel, J P; Feuerstein, C; Bittel, J H
1996-01-01
To study relationships between local cold adaptation of the lower limbs and general cold adaptation, eight subjects were submitted both to a cold foot test (CFT, 5 degrees C water immersion, 5 min) and to a whole-body standard cold air test (SCAT, 1 degree C, 2 h, nude at rest) before and after a local cold acclimation (LCA) of the lower limbs effected by repeated cold water immersions. The LCA induced a local cold adaptation confirmed by higher skin temperatures of the lower limbs during CFT and a hypothermic insulative general cold adaptation (decreased rectal temperature and mean skin temperature P < 0.05) without a change either in metabolic heat production or in lower limb skin temperatures during SCAT after LCA. It was concluded that local cold adaptation was related to the habituation process confirmed by decreased plasma concentrations of noradrenaline (NA) during LCA (P < 0.05). However, the hypothermic insulative general cold adaptation was unrelated either to local cold adaptation or to the habituation process, because an increased NA during SCAT after LCA (P < 0.05) was observed but was rather related to a "T3 polar syndrome" occurring during LCA.
Ishizaki, Takahiro; Sakamoto, Michiru
2011-03-15
The design of color-tuned magnesium alloy with anticorrosive properties and damping capacity was created by means of a simple and inexpensive method. The vertically self-aligned nano- and microsheets were formed on magnesium alloy AZ31 by a chemical-free immersion process in ultrapure water at a temperature of 120 °C, resulting in the color expression. The color changed from silver with metallic luster to some specific colors such as orange, green, and orchid, depending on the immersion time. The color-tuned magnesium alloy showed anticorrosive performance and damping capacity. In addition, the colored surface with minute surface textures was modified with n-octadecyltrimethoxysilane (ODS), leading to the formation of color-tuned superhydrophobic surfaces. The corrosion resistance of the color-tuned superhydrophobic magnesium alloy was also investigated using electrochemical potentiodynamic measurements. Moreover, the color-tuned superhydrophobic magnesium alloy showed high hydrophobicity not just for pure water but also for corrosive liquids, such as acidic, basic, and some aqueous salt solutions. In addition, the American Society for Testing and Materials (ASTM) standard D 3359-02 cross cut tape test was performed to investigate the adhesion of the color-tuned superhydrophobic film to the magnesium alloy surface.
Isolated effects of peripheral arm and central body cooling on arm performance.
Giesbrecht, G G; Wu, M P; White, M D; Johnston, C E; Bristow, G K
1995-10-01
Whole body cooling impairs manual arm performance. The independent contributions of local (peripheral) and/or whole body (central) cooling are not known. Therefore, a protocol was developed in which the arm and the rest of the body could be independently cooled. Biceps temperature (Tmus), at a depth of 20 mm, and esophageal temperature (Tes) were measured. Six subjects were immersed to the clavicles in a tank (body tank) of water under 3 conditions: 1) cold body-cold arm (CB-CA); 2) warm body-cold arm (WB-CA); and 3) cold body-warm arm (CB-WA). In the latter two conditions, subjects placed their dominant arm in a separate (arm) tank. Water temperature (Tw) in each tank was independently controlled. In conditions requiring cold body and/or cold arm, Tw in the appropriate tanks was 8 degrees C. In conditions requiring warm body and/or warm arm, Tw in the appropriate tanks was adjusted between 29 and 38 degrees C to maintain body/arm temperature at baseline values. A battery of 6 tests, requiring fine or gross motor movements, were performed immediately before immersion and after 15, 45, and 70 minutes of immersion. In CB-CA, Tes decreased from an average of 37.2 to 35.6 degrees C and Tmus decreased from 34.6 to 22.0 degrees C. In WB-CA, Tmus decreased to 18.1 degrees C (Tes = 37.1 degrees C), and in CB-WA, Tes decreased to 35.8 degrees C (Tmus = 34.5 degrees C). By the end of immersion, there were significant decrements (43-85%) in the performance of all tests in CB-CA and WB-CA (p < 0.0002); scores for each test were similar in these two conditions. There was no significant change in scores throughout the CB-WA condition. In both conditions with arm cooling (i.e., WB-CA and CB-CA), Tmus accounted for 85-98% of the variance in all tests. When the core was cooled in the CB-WA condition, Tes was significantly correlated to scores in only two tests (accounted for 90 and 93% of the variance) although the actual effect was small. In the CB-CA condition, partial correlations indicated that Tes accounted for 4-10% of the variance in scores of 4 tests. We conclude that cooling of the body and/or the arm elicits large decrements in finger, hand and arm performance. The decrements are due almost entirely to the local effects of arm tissue cooling.
NASA Astrophysics Data System (ADS)
Hiranuma, N.; Augustin-Bauditz, S.; Bingemer, H.; Budke, C.; Curtius, J.; Danielczok, A.; Diehl, K.; Dreischmeier, K.; Ebert, M.; Frank, F.; Hoffmann, N.; Kandler, K.; Kiselev, A.; Koop, T.; Leisner, T.; Möhler, O.; Nillius, B.; Peckhaus, A.; Rose, D.; Weinbruch, S.; Wex, H.; Boose, Y.; DeMott, P. J.; Hader, J. D.; Hill, T. C. J.; Kanji, Z. A.; Kulkarni, G.; Levin, E. J. T.; McCluskey, C. S.; Murakami, M.; Murray, B. J.; Niedermeier, D.; Petters, M. D.; O'Sullivan, D.; Saito, A.; Schill, G. P.; Tajiri, T.; Tolbert, M. A.; Welti, A.; Whale, T. F.; Wright, T. P.; Yamashita, K.
2015-03-01
Immersion freezing is the most relevant heterogeneous ice nucleation mechanism through which ice crystals are formed in mixed-phase clouds. In recent years, an increasing number of laboratory experiments utilizing a variety of instruments have examined immersion freezing activity of atmospherically relevant ice-nucleating particles. However, an intercomparison of these laboratory results is a difficult task because investigators have used different ice nucleation (IN) measurement methods to produce these results. A remaining challenge is to explore the sensitivity and accuracy of these techniques and to understand how the IN results are potentially influenced or biased by experimental parameters associated with these techniques. Within the framework of INUIT (Ice Nuclei Research Unit), we distributed an illite-rich sample (illite NX) as a representative surrogate for atmospheric mineral dust particles to investigators to perform immersion freezing experiments using different IN measurement methods and to obtain IN data as a function of particle concentration, temperature (T), cooling rate and nucleation time. A total of 17 measurement methods were involved in the data intercomparison. Experiments with seven instruments started with the test sample pre-suspended in water before cooling, while 10 other instruments employed water vapor condensation onto dry-dispersed particles followed by immersion freezing. The resulting comprehensive immersion freezing data set was evaluated using the ice nucleation active surface-site density, ns, to develop a representative ns(T) spectrum that spans a wide temperature range (-37 °C < T < -11 °C) and covers 9 orders of magnitude in ns. In general, the 17 immersion freezing measurement techniques deviate, within a range of about 8 °C in terms of temperature, by 3 orders of magnitude with respect to ns. In addition, we show evidence that the immersion freezing efficiency expressed in ns of illite NX particles is relatively independent of droplet size, particle mass in suspension, particle size and cooling rate during freezing. A strong temperature dependence and weak time and size dependence of the immersion freezing efficiency of illite-rich clay mineral particles enabled the ns parameterization solely as a function of temperature. We also characterized the ns(T) spectra and identified a section with a steep slope between -20 and -27 °C, where a large fraction of active sites of our test dust may trigger immersion freezing. This slope was followed by a region with a gentler slope at temperatures below -27 °C. While the agreement between different instruments was reasonable below ~ -27 °C, there seemed to be a different trend in the temperature-dependent ice nucleation activity from the suspension and dry-dispersed particle measurements for this mineral dust, in particular at higher temperatures. For instance, the ice nucleation activity expressed in ns was smaller for the average of the wet suspended samples and higher for the average of the dry-dispersed aerosol samples between about -27 and -18 °C. Only instruments making measurements with wet suspended samples were able to measure ice nucleation above -18 °C. A possible explanation for the deviation between -27 and -18 °C is discussed. Multiple exponential distribution fits in both linear and log space for both specific surface area-based ns(T) and geometric surface area-based ns(T) are provided. These new fits, constrained by using identical reference samples, will help to compare IN measurement methods that are not included in the present study and IN data from future IN instruments.
NASA Astrophysics Data System (ADS)
Hiranuma, N.; Augustin-Bauditz, S.; Bingemer, H.; Budke, C.; Curtius, J.; Danielczok, A.; Diehl, K.; Dreischmeier, K.; Ebert, M.; Frank, F.; Hoffmann, N.; Kandler, K.; Kiselev, A.; Koop, T.; Leisner, T.; Möhler, O.; Nillius, B.; Peckhaus, A.; Rose, D.; Weinbruch, S.; Wex, H.; Boose, Y.; DeMott, P. J.; Hader, J. D.; Hill, T. C. J.; Kanji, Z. A.; Kulkarni, G.; Levin, E. J. T.; McCluskey, C. S.; Murakami, M.; Murray, B. J.; Niedermeier, D.; Petters, M. D.; O'Sullivan, D.; Saito, A.; Schill, G. P.; Tajiri, T.; Tolbert, M. A.; Welti, A.; Whale, T. F.; Wright, T. P.; Yamashita, K.
2014-08-01
Immersion freezing is the most relevant heterogeneous ice nucleation mechanism through which ice crystals are formed in mixed-phase clouds. In recent years, an increasing number of laboratory experiments utilizing a variety of instruments have examined immersion freezing activity of atmospherically relevant ice nucleating particles (INPs). However, an inter-comparison of these laboratory results is a difficult task because investigators have used different ice nucleation (IN) measurement methods to produce these results. A remaining challenge is to explore the sensitivity and accuracy of these techniques and to understand how the IN results are potentially influenced or biased by experimental parameters associated with these techniques. Within the framework of INUIT (Ice Nucleation research UnIT), we distributed an illite rich sample (illite NX) as a representative surrogate for atmospheric mineral dust particles to investigators to perform immersion freezing experiments using different IN measurement methods and to obtain IN data as a function of particle concentration, temperature (T), cooling rate and nucleation time. Seventeen measurement methods were involved in the data inter-comparison. Experiments with seven instruments started with the test sample pre-suspended in water before cooling, while ten other instruments employed water vapor condensation onto dry-dispersed particles followed by immersion freezing. The resulting comprehensive immersion freezing dataset was evaluated using the ice nucleation active surface-site density (ns) to develop a representative ns(T) spectrum that spans a wide temperature range (-37 °C < T < -11 °C) and covers nine orders of magnitude in ns. Our inter-comparison results revealed a discrepancy between suspension and dry-dispersed particle measurements for this mineral dust. While the agreement was good below ~ -26 °C, the ice nucleation activity, expressed in ns, was smaller for the wet suspended samples and higher for the dry-dispersed aerosol samples between about -26 and -18 °C. Only instruments making measurement techniques with wet suspended samples were able to measure ice nucleation above -18 °C. A possible explanation for the deviation between -26 and -18 °C is discussed. In general, the seventeen immersion freezing measurement techniques deviate, within the range of about 7 °C in terms of temperature, by three orders of magnitude with respect to ns. In addition, we show evidence that the immersion freezing efficiency (i.e., ns) of illite NX particles is relatively independent on droplet size, particle mass in suspension, particle size and cooling rate during freezing. A strong temperature-dependence and weak time- and size-dependence of immersion freezing efficiency of illite-rich clay mineral particles enabled the ns parameterization solely as a function of temperature. We also characterized the ns (T) spectra, and identified a section with a steep slope between -20 and -27 °C, where a large fraction of active sites of our test dust may trigger immersion freezing. This slope was followed by a region with a gentler slope at temperatures below -27 °C. A multiple exponential distribution fit is expressed as ns(T) = exp(23.82 × exp(-exp(0.16 × (T + 17.49))) + 1.39) based on the specific surface area and ns(T) = exp(25.75 × exp(-exp(0.13 × (T + 17.17))) + 3.34) based on the geometric area (ns and T in m-2 and °C, respectively). These new fits, constrained by using an identical reference samples, will help to compare IN measurement methods that are not included in the present study and, thereby, IN data from future IN instruments.
Sveälv, Bente Grüner; Täng, Margareta Scharin; Cider, Åsa
2012-01-01
Hydrotherapy (exercise in warm water) is considered to be a safe and beneficial method to use in the rehabilitation of stable heart failure patients, but there is little information on the effect of the increased venous return and enhanced preload in elderly patients with biventricular heart failure. We present a case of an elderly man who was recruited to participate in a hydrotherapy study. We compared echocardiographic data during warm water immersion with land measurements, and observed increases in stroke volume from 32 mL (land) to 42 mL (water), left ventricular ejection fraction from 22% to 24%, left ventricular systolic velocity from 4.8 cm/s to 5.0 cm/s and left atrioventricular plane displacement from 2.1 mm to 2.2 mm. By contrast, right ventricular systolic velocity decreased from 11.2 cm/s to 8.4 cm/s and right atrioventricular plane displacement from 8.1 mm to 4.7 mm. The tricuspid pressure gradient rose from 18 mmHg on land to 50 mmHg during warm water immersion. Thus, although left ventricular systolic function was relatively unaffected during warm water immersion, we observed a decrease in right ventricular function with an augmented right ventricular pressure. We recommend further investigations to observe the cardiac effect of warm water immersion on patients with biventricular systolic heart failure and at risk of elevated right ventricular pressure. PMID:23341846
Discoloration of various CAD/CAM blocks after immersion in coffee.
Lauvahutanon, Sasipin; Shiozawa, Maho; Takahashi, Hidekazu; Iwasaki, Naohiko; Oki, Meiko; Finger, Werner J; Arksornnukit, Mansuang
2017-02-01
This study evaluated color differences (Δ E s) and translucency parameter changes (Δ TP s) of various computer-aided design/computer-aided manufacturing (CAD/CAM) blocks after immersion in coffee. Eight CAD/CAM blocks and four restorative composite resins were evaluated. The CIE L * a * b * values of 2.0 mm thick disk-shaped specimens were measured using the spectrophotometer on white and black backgrounds ( n = 6). The Δ E s and Δ TP s of one day, one week, and one month immersion in coffee or water were calculated. The values of each material were analyzed by two-way ANOVA and Tukey's multiple comparisons (α = 0.05). The Δ E s after prophylaxis paste polishing of 1 month coffee immersion specimens, water sorption and solubility were also evaluated. After one month in coffee, Δ E s of CAD/CAM composite resin blocks and restorative composites ranged from 1.6 to 3.7 and from 2.1 to 7.9, respectively, and Δ TP s decreased. The ANOVA of Δ E s and Δ TP s revealed significant differences in two main factors, immersion periods and media, and their interaction except for Δ E s of TEL (Telio CAD, Ivoclar Vivadent). The Δ E s significantly decreased after prophylaxis polishing except GRA (Gradia Block, GC). There was no significant correlation between Δ E s and water sorption or solubility in water. The Δ E s of CAD/CAM blocks after immersion in coffee varied among products and were comparable to those of restorative composite resins. The discoloration of CAD/CAM composite resin blocks could be effectively removed with prophylaxis paste polishing, while that of some restorative composites could not be removed.
Mechanism of Thirst Attenuation During Head-Out Water Immersion in Men
NASA Technical Reports Server (NTRS)
Wada, F.; Sagawa, S.; Miki, K.; Nagaya, K.; Nakamitsu, S.; Shiraki, K.; Greenleaf, J. E.
1994-01-01
The purpose was to determine whether extracellular volume or osmolality was the major contributing factor for reduction of thirst in air and head-out water immersion in hypohydrated subjects. Eight males (19 - 25 yr) were subjected to thermoneutral immersion and thermoneutral air under two hydration conditions without further drinking: euhydration in water (Eu-H2O) and euhydration in air, and hypohydration in water (Hypo-H2O) and hypohydration in air (3.7% wt loss after exercise in heat). The increased thirst sensation with Hypo-H2O decreased (P less than 0.05) within 10 min of immersion and continued thereafter. Mean plasma osmolality (288 +/- 1 mosmol/kg H2O) and sodium (140 +/- 1 meq/1) remained elevated, and plasma volume increased by 4.2 +/- 1.0% (P less than 0.05) throughout Hypo-H2O. A sustained increase (P less than 0.05) in stroke volume accompanied the prompt and sustained decrease in plasma renin activity and sustained increase (P less than 0.05) in plasma atrial natriuretic peptide during Eu-H2O and Hypo-H2O. Plasma vasopressin decreased from 5.3 +/- 0.7 to 2.9 +/- 0.5 pg/ml (P less than 0.05) during Hypo-H2O but was unchanged in Eu-H2O. These findings suggest a sustained stimulation of the atrial baroreceptors and reduction of a dipsogenic stimulus without major alterations of extracellular osmolality in Hypo-H2O. Thus it appears that vascular volume induced stimuli of cardiopulmonary baroreceptors play a more important role than extracellular osmolality in reducing thirst sensations during immersion in hypohydrated subjects. Thus the purpose for this study was to determine the relative importance of volume and osmotic stimuli, and associated hormonal interaction, for attenuation of thirst during immersion.
Corrosion behavior and microhardness of three amalgams.
Patsurakos, A; Moberg, L E
1988-08-01
The marginal microhardness of three different types of amalgam was tested after 2 months' immersion in an aqueous solution of NaCl (85 mM) and phosphates (Na2HPO4 100 mM and NaH2PO4 100 mM). Amalgams immersed in distilled water were used as controls. The microhardness tests were conducted at a distance of 50 micron from the margins and at the bulk of each specimen. The solutions were analyzed for Sn, Cu, Zn, Ag, and Hg by means of atomic absorption spectrophotometry (AAS). A statistically significant reduction in the marginal microhardness after immersion in the test solution was found for the conventional and the high-Cu single composition amalgam but not for the high-Cu blended amalgam. SEM-examination of cross-sections of the amalgams revealed small areas of subsurface grain boundary corrosion, no deeper than 10 micron for all the amalgams. The SEM-examination of the specimens and AAS analysis of the solutions indicated that the reduction in marginal microhardness was attributed mainly to corrosion of the Cu-rich phases for the high-Cu single composition amalgam and to corrosion of the gamma 2 phase for the conventional amalgam. The phosphates reduced the corrosion of the amalgams in the presence of NaCl. It is concluded that the marginal strength of dental amalgams in a corrosive environment is largely dependent upon their corrosion resistance.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-01-06
... barriers would affect a human body if immersed in the water. The NEDU final report concluded that the possible effects to a human body if immersed in the water include paralysis of body muscles, inability to... body of your document so that we can contact you if we have questions regarding your submission. To...
Neppelenbroek, Karin Hermana; Urban, Vanessa Migliorini; de Oliveira, Denise Gusmão; Porto, Vinícius Carvalho; Almilhatti, Hercules Jorge; Campanha, Nara Hellen
2016-01-01
Background: Detachment of denture acrylic resin artificial teeth from denture base resin is one of the most common problems presented by denture wearers. Purpose: This study investigated the shear bond strength (SBS) and fracture type of bonding interface of two commercial acrylic teeth (Vipi Dent Plus e Biolux) to two denture base resins (Vipi Cril e Lucitone 550) after immersion in potentially chromogenic beverages (coffee, cola soft drink, and red wine) or control solution (distilled water). Materials and Methods: Maxillary central incisor acrylic teeth were placed at 45° to denture base resin and submitted to short polymerization cycle according to manufacturers. Specimens were divided according to the combination tooth/resin/solution (n = 8) and submitted to bond strength tests in a universal testing machine MTS-810 (0.5 mm/min). Subsequently, fracture area was analyzed by stereomicroscope at a magnification of ×10 and categorized into adhesive, cohesive, or mixed failure. Results: The bond strength of teeth/denture base resins interface was not significantly affected by tested solutions (P > 0.087), except for Biolux teeth immersed in coffee (P < 0.01). In all conditions, the Vipi Dent Plus teeth showed higher bond strength to Lucitone and Vipi Cril resins when compared to Biolux teeth (P < 0.003). All specimens’ failure modes were cohesive. Conclusions: The SBS of acrylic teeth to denture base resins was not generally influenced by immersion in the tested staining beverages. PMID:27621547
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Yuxin; Wen, Wenhui; Wang, Kai
2016-01-11
1700-nm window has been demonstrated to be a promising excitation window for deep-tissue multiphoton microscopy (MPM). Long working-distance water immersion objective lenses are typically used for deep-tissue imaging. However, absorption due to immersion water at 1700 nm is still high and leads to dramatic decrease in signals. In this paper, we demonstrate measurement of absorption spectrum of deuterium oxide (D{sub 2}O) from 1200 nm to 2600 nm, covering the three low water-absorption windows potentially applicable for deep-tissue imaging (1300 nm, 1700 nm, and 2200 nm). We apply this measured result to signal enhancement in MPM at the 1700-nm window. Compared with water immersion, D{sub 2}O immersionmore » enhances signal levels in second-harmonic generation imaging, 3-photon fluorescence imaging, and third-harmonic generation imaging by 8.1, 24.8, and 24.7 times with 1662-nm excitation, in good agreement with theoretical calculation based on our absorption measurement. This suggests D{sub 2}O a promising immersion medium for deep-tissue imaging.« less
Venkitanarayanan, K S; Ezeike, G O; Hung, Y C; Doyle, M P
1999-08-01
One milliliter of culture containing a five-strain mixture of Escherichia coli O157:H7 (approximately 10(10) CFU) was inoculated on a 100-cm2 area marked on unscarred cutting boards. Following inoculation, the boards were air-dried under a laminar flow hood for 1 h, immersed in 2 liters of electrolyzed oxidizing water or sterile deionized water at 23 degrees C or 35 degrees C for 10 or 20 min; 45 degrees C for 5 or 10 min; or 55 degrees C for 5 min. After each temperature-time combination, the surviving population of the pathogen on cutting boards and in soaking water was determined. Soaking of inoculated cutting boards in electrolyzed oxidizing water reduced E. coli O157:H7 populations by > or = 5.0 log CFU/100 cm2 on cutting boards. However, immersion of cutting boards in deionized water decreased the pathogen count only by 1.0 to 1.5 log CFU/100 cm2. Treatment of cutting boards inoculated with Listeria monocytogenes in electrolyzed oxidizing water at selected temperature-time combinations (23 degrees C for 20 min, 35 degrees C for 10 min, and 45 degrees C for 10 min) substantially reduced the populations of L. monocytogenes in comparison to the counts recovered from the boards immersed in deionized water. E. coli O157:H7 and L. monocytogenes were not detected in electrolyzed oxidizing water after soaking treatment, whereas the pathogens survived in the deionized water used for soaking the cutting boards. This study revealed that immersion of kitchen cutting boards in electrolyzed oxidizing water could be used as an effective method for inactivating foodborne pathogens on smooth, plastic cutting boards.
Influence of investment, disinfection, and storage on the microhardness of ocular resins.
Goiato, Marcelo Coelho; dos Santos, Daniela Micheline; Gennari-Filho, Humberto; Zavanelli, Adriana Cristina; Dekon, Stefan Fiuza de Carvalho; Mancuso, Daniela Nardi
2009-01-01
The longevity of an ocular prosthesis is directly related to the resistance to erosion of its material. The purpose of this study was to evaluate the effects of chemical disinfection and the method of investment on the microhardness of ocular prosthesis acrylic resin. Thirty-two test specimen investments were obtained in two silicones. A segment was cut in each test specimen, and each specimen was fixed in an acrylic disk. The specimens were then polished and submitted to the first microhardness test before immersion in distilled water and incubation for 2 months. During this 2-month period, the specimens were immersed in a water bath at 37 degrees C and were disinfected daily; half were disinfected with neutral soap and the other half were disinfected with 4% chlorhexidine gluconate. After the storage phase and disinfection, a second microhardness test was performed. The surface microhardness values for the acrylic resins were submitted to ANOVA, followed by the Tukey test. The disinfection and the period of storage did not statistically influence the surface microhardness of the acrylic resin, independent of the method of investment of the specimens (Zetalabor or Vipi Sil). The investment of specimens with Zetalabor silicone presented a greater surface hardness, independent of the type of disinfection and the period of storage. Based on these results, we suggest that the microhardness of the resin evaluated was not influenced by the method of disinfection or the time of storage used and was affected only by the investment material.
NASA Astrophysics Data System (ADS)
Julia, J. E.; Hernández, L.; Martínez-Cuenca, R.; Hibiki, T.; Mondragón, R.; Segarra, C.; Jarque, J. C.
2012-11-01
Forced convective heat transfer coefficient and pressure drop of SiO2- and Al2O3-water nanofluids were characterized. The experimental facility was composed of thermal-hydraulic loop with a tank with an immersed heater, a centrifugal pump, a bypass with a globe valve, an electromagnetic flow-meter, a 18 kW in-line pre-heater, a test section with band heaters, a differential pressure transducer and a heat exchanger. The test section consists of a 1000 mm long aluminium pipe with an inner diameter of 31.2 mm. Eighteen band heaters were placed all along the test section in order to provide a uniform heat flux. Heat transfer coefficient was calculated measuring fluid temperature using immersed thermocouples (Pt100) placed at both ends of the test section and surface thermocouples in 10 axial locations along the test section (Pt1000). The measurements have been performed for different nanoparticles (Al2O3 and SiO2 with primary size of 11 nm and 12 nm, respectively), volume concentrations (1% v., 5% v.), and flow rates (3 103Re<105). Maximum heat transfer coefficient enhancement (300%) and pressure drop penalty (1000%) is obtained with 5% v. SiO2 nanofluid. Existing correlations can predict, at least in a first approximation, the heat transfer coefficient and pressure drop of nanofluids if thermal conductivity, viscosity and specific heat were properly modelled.
Keith Reinhardt; William K. Smith
2010-01-01
The red spruce-Fraser fir ecosystem (Picea rubens Sarg.-Abies fraseri [Pursh] Poir.) of the southern Appalachian mountains is a temperate zone cloud forest immersed in clouds for 30 to 40 percent of a typical summer day, and experiencing immersion on about 65 percent of all days annually. We compared the microclimate,...
Daniel M. Johnson; William K. Smith
2008-01-01
The high altitude spruce-fir (Abies fraseri (Pursh) Poiret.-Picea rubens Sarg.) forests of the southern Appalachian Mountains, USA, experience frequent cloud immersion. Recent studies indicate that cloud bases may have risen over the past 30 years, resulting in less frequent forest cloud immersion, and that further increases in...
Guillén, Sofía; Mir-Bel, Jorge; Oria, Rosa; Salvador, María L
2017-02-15
Colour, pigments, total phenolic content and antioxidant activity were investigated in artichokes, green beans, broccoli and carrots cooked under different conditions. Domestic induction hobs with temperature control were used to evaluate the effect of boiling, sous-vide cooking and water immersion cooking at temperatures below 100°C on the properties of each vegetable. Sous-vide cooking preserved chlorophyll, carotenoids, phenolic content and antioxidant activity to a greater extent than boiling for all of the vegetables tested and retained colour better, as determined by a(∗). A reduction of only 10-15°C in the cooking temperature was enough to improve the properties of the samples cooked by water immersion, except for green beans. Artichokes and carrots suffered pronounced losses of antioxidant activity during boiling (17.0 and 9.2% retention, respectively), but the stability of this parameter significantly increased with sous-vide cooking (84.9 and 55.3% retention, respectively). Copyright © 2016 Elsevier Ltd. All rights reserved.
The Effects of Multiple Cold Water Immersions on Indices of Muscle Damage
Goodall, Stuart; Howatson, Glyn
2008-01-01
The aim of this investigation was to elucidate the efficacy of repeated cold water immersions (CWI) in the recovery of exercise induced muscle damage. A randomised group consisting of eighteen males, mean ± s age, height and body mass were 24 ± 5 years, 1.82 ± 0.06 m and 85.7 ± 16.6 kg respectively, completed a bout of 100 drop jumps. Following the bout of damaging exercise, participants were randomly but equally assigned to either a 12 min CWI (15 ± 1 °C; n = 9) group who experienced immersions immediately post-exercise and every 24 h thereafter for the following 3 days, or a control group (no treatment; n = 9). Maximal voluntary contraction (MVC) of the knee extensors, creatine kinase activity (CK), muscle soreness (DOMS), range of motion (ROM) and limb girth were measured pre-exercise and then for the following 96 h at 24 h increments. In addition MVC was also recorded immediately post-exercise. Significant time effects were seen for MVC, CK, DOMS and limb girth (p < 0.05) indicating muscle damage was evident, however there was no group effect or interaction observed showing that CWI did not attenuate any of the dependent variables (p > 0.05). These results suggest that repeated CWI do not enhance recovery from a bout of damaging eccentric contractions. Key pointsCryotherapy, particularly cold water immersions are one of the most common interventions used in order to enhance recovery post-exercise.There is little empirical evidence demonstrating benefits from cold water immersions. Research evidence is equivocal, probably due to methodological inconsistencies.Our results show that the cryotherapy administered did not attenuate any markers of EIMD or enhance the recovery of function.We conclude that repeated cold water immersions are ineffective in the recovery from heavy plyometric exercise and suggest athletes and coaches should use caution before using this intervention as a recovery strategy PMID:24149455
Immersion in water in labour and birth
Cluett, Elizabeth R; Burns, Ethel
2014-01-01
Background Enthusiasts suggest that labouring in water and waterbirth increase maternal relaxation, reduce analgesia requirements and promote a midwifery model of care. Critics cite the risk of neonatal water inhalation and maternal/neonatal infection. Objectives To assess the evidence from randomised controlled trials about immersion in water during labour and waterbirth on maternal, fetal, neonatal and caregiver outcomes. Search methods We searched the Cochrane Pregnancy and Childbirth Group’s Trials Register (30 June 2011) and reference lists of retrieved studies. Selection criteria Randomised controlled trials comparing immersion in any bath tub/pool with no immersion, or other non-pharmacological forms of pain management during labour and/or birth, in women during labour who were considered to be at low risk of complications, as defined by the researchers. Data collection and analysis We assessed trial eligibility and quality and extracted data independently. One review author entered data and the other checked for accuracy. Main results This review includes 12 trials (3243 women): eight related to just the first stage of labour: one to early versus late immersion in the first stage of labour; two to the first and second stages; and another to the second stage only. We identified no trials evaluating different baths/pools, or the management of third stage of labour. Results for the first stage of labour showed there was a significant reduction in the epidural/spinal/paracervical analgesia/anaesthesia rate amongst women allocated to water immersion compared to controls (478/1254 versus 529/1245; risk ratio (RR) 0.90; 95% confidence interval (CI) 0.82 to 0.99, six trials). There was also a reduction in duration of the first stage of labour (mean difference −32.4 minutes; 95% CI −58.7 to −6.13). There was no difference in assisted vaginal deliveries (RR 0.86; 95% CI 0.71 to 1.05, seven trials), caesarean sections (RR 1.21; 95% CI 0.87 to 1.68, eight trials), use of oxytocin infusion (RR 0.64; 95%CI 0.32 to 1.28,five trials), perineal trauma or maternal infection. There were no differences for Apgar score less than seven at five minutes (RR 1.58; 95% CI 0.63 to 3.93, five trials), neonatal unit admissions (RR 1.06; 95% CI 0.71 to 1.57, three trials), or neonatal infection rates (RR 2.00; 95% CI 0.50 to 7.94, five trials). Of the three trials that compared water immersion during the second stage with no immersion, one trial showed a significantly higher level of satisfaction with the birth experience (RR 0.24; 95% CI 0.07 to 0.80). A lack of data for some comparisons prevented robust conclusions. Further research is needed. Authors’ conclusions Evidence suggests that water immersion during the first stage of labour reduces the use of epidural/spinal analgesia and duration of the first stage of labour. There is limited information for other outcomes related to water use during the first and second stages of labour, due to intervention and outcome variability. There is no evidence of increased adverse effects to the fetus/neonate or woman from labouring in water or waterbirth. However, the studies are very variable and considerable heterogeneity was detected for some outcomes. Further research is needed. PMID:19370552
Breath-hold time during cold water immersion: effects of habituation with psychological training.
Barwood, Martin J; Datta, Avijit K; Thelwell, Richard C; Tipton, Michael J
2007-11-01
The loss of the conscious control of respiration on whole body cold water immersion (CWI) can result in the aspiration of water and drowning. Repeated CWI reduces the respiratory drive evoked by CWI and should prolong breath-hold time on CWI (BHmax(CWI)). Psychological skills training (PST) can also increase BHmax(CWI) by improving the ability of individuals to consciously suppress the drive to breathe. This study tested the hypothesis that combining PST and repeated CWI would extend BHmax(CWI) beyond that seen following only repeated CWI. There were 20 male subjects who completed two 2.5-min, head-out breath-hold CWI (BH1 and BH2) in water at 12 degrees C. Following BH1, subjects were matched on BHmax(CWI) and allocated to a habituation (HAB) group or a habituation plus PST group (H+PST). Between BH1 and BH2 both experimental groups undertook five 2.5-min CWI on separate days, during which they breathed freely. The H+PST also received psychological training to help tolerate cold and suppress the drive to breathe on immersion to extend BHmax(CWI). During BH1, mean BHmax(CWI) (+/- SD) in the HAB group was 22.00 (10.33) s and 22.38 (10.65) s in the H+PST. After the five free-breathing CWI, both groups had a longer BHmax(CWI) in BH2. The HAB group improved by 14.13 (20.21) s, an increase of 73%. H+PST improved by 26.86 (24.70) s, a 120% increase. No significant differences were identified between the groups. Habituation significantly increases BHmax on CWI, the addition of PST did not result in statistically significant improvements in BHmax(CWI), but may have practical significance.
Influence of temperature on Cole-Cole dielectric model of oil-immersed bushing
NASA Astrophysics Data System (ADS)
Wang, K.; Chen, X. J.; Xu, X. W.; Liu, G. Q.; Zou, D. X.; Liu, W. D.
2017-07-01
In this paper, 72.5 kV oil-immersed bushing was produced in laboratory. The frequency-domain dielectric response tests of oil-immersed bushings were carried out at different test temperatures. The experimental data were fitted by using the modified double relaxation Cole-Cole dielectric model. The influence of temperature variation on the dielectric response test of the oil-immersed bushing and the Cole-Cole dielectric model parameters were analysed. The results showed that with the increase of the test temperature, the spectrum of the real and imaginary of the complex permittivity are shifted to the high frequency direction; the parameters of the dielectric model are significantly affected by temperature.
Almeida, Aline C; Machado, Aryane F; Albuquerque, Maíra C; Netto, Lara M; Vanderlei, Franciele M; Vanderlei, Luiz Carlos M; Junior, Jayme Netto; Pastre, Carlos M
2016-08-01
The aim of the present study was to investigate the effects of cold water immersion during post-exercise recovery, with different durations and temperatures, on heart rate variability indices. Hundred participants performed a protocol of jumps and a Wingate test, and immediately afterwards were immersed in cold water, according to the characteristics of each group (CG: control; G1: 5' at 9±1°C; G2: 5' at 14±1°C; G3: 15' at 9±1°C; G4: 15' at 14±1°C). Analyses were performed at baseline, during the CWI recuperative technique (TRec) and 20, 30, 40, 50 and 60min post-exercise. The average HRV indices of all RR-intervals in each analysis period (MeanRR), standard deviation of normal RR-intervals (SDNN), square root of the mean of the sum of the squares of differences between adjacent RR-intervals (RMSSD), spectral components of very low frequency (VLF), low frequency (LF) and high frequency (HF), scatter of points perpendicular to the line of identity of the Poincaré Plot (SD1) and scatter points along the line of identity (SD2) were assessed. Mean RR, VLF and LF presented an anticipated return to baseline values at all the intervention groups, but the same was observed for SDNN and SD2 only in the immersion for 15min at 14°C group (G4). In addition, G4 presented higher values when compared to CG. These findings demonstrate that if the purpose of the recovery process is restoration of cardiac autonomic modulation, the technique is recommended, specifically for 15min at 14°C. Copyright © 2015 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Cui, Mingjun; Ren, Siming; Chen, Jia; Liu, Shuan; Zhang, Guangan; Zhao, Haichao; Wang, Liping; Xue, Qunji
2017-03-01
Homogenous dispersion of hexagonal boron nitride (h-BN) nanosheets in solvents or in the polymer matrix is crucial to initiate their many applications. Here, homogeneous dispersion of hexagonal boron nitride (h-BN) in epoxy matrix was achieved with a water-soluble carboxylated aniline trimer derivative (CAT-) as a dispersant, which was attributed to the strong π-π interaction between h-BN and CAT-, as proved by Raman and UV-vis spectra. Transmission electron microscopy (TEM) analysis confirmed a random dispersion of h-BN nanosheets in the waterborne epoxy coatings. The deterioration process of water-borne epoxy coating with and without h-BN nanosheets during the long-term immersion in 3.5 wt% NaCl solution was investigated by electrochemical measurements and water absorption test. Results implied that the introduction of well dispersed h-BN nanosheets into waterborne epoxy system remarkably improved the corrosion protection performance to substrate. Moreover, 1 wt% BN/EP composite coated substrate exhibited higher impedance modulus (1.3 × 106 Ω cm2) and lower water absorption (4%) than those of pure waterborne epoxy coating coated electrode after long-term immersion in 3.5 wt% NaCl solution, demonstrating its superior anticorrosive performance. This enhanced anticorrosive performance was mainly ascribed to the improved water barrier property of epoxy coating via incorporating homogeneously dispersed h-BN nanosheets.
Newport, Matthew; Grayson, Alan
2012-10-01
A short cut review was carried out to establish whether whole body ice immersion was an effective way of cooling in patients presenting with heat stroke. One systematic review and three studies were directly relevant to the question. The author, date and country of publication, patient group studied, study type, relevant outcomes, results and study weaknesses of these papers are tabulated. The clinical bottom line was that immersion in ice-water was the most effective modality of lowering core body temperature in exertional heatstroke and shivering and vasoconstriction concerns were unfounded.
Heats of immersion of titania powders in primer solutions
NASA Technical Reports Server (NTRS)
Siriwardane, R.; Wightman, J. P.
1983-01-01
The oxide layer present on titanium alloys can play an important role in determining the strength and durability of adhesive bonds. Here, three titania powders in different crystalline phases, rutile-R1, anatase-A1, and anatase-A2, are characterized by several techniques. These include microelectrophoresis, X-ray diffractometry, surface area pore volume analysis, X-ray photoelectron spectroscopy, and measurements of the heats of immersion. Of the three powders, R1 has the highest heat of immersion in water, while the interaction between water and A1 powder is low. Experimental data also suggest a specific preferential interaction of polyphenylquinoxaline with anatase.
Aquatic therapies in patients with compromised left ventricular function and heart failure.
Meyer, Katharina; Leblanc, Marie-Claude
2008-01-01
With water immersion, gravity is partly eliminated, and the water exerts a pressure on the body surface. Consequently there is a blood volume shift from the periphery to the central circulation, resulting in marked volume loading of the thorax and heart. This paper presents a selection of published literature on water immersion, balneotherapy, aqua exercises, and swimming, in patients with left ventricular dysfunction (LVD) and/or stable chronic heart failure (CHF). Based on exploratory studies, central hemodynamic and neurohumoral responses of aquatic therapies will be illustrated. Major findings are: 1. In LVD and CHF, a positive effect of therapeutic warm-water tub bathing has been observed, which is assumed to be from afterload reduction due to peripheral vasodilatation caused by the warm water. 2. In coronary patients with LVD, at low-level water cycling the heart is working more efficiently than at lowlevel cycling outside of water. 3. In patients with previous extensive myocardial infarction, upright immersion to the neck resulted in temporary pathological increases in mean pulmonary artery pressure (mPAP) and mean pulmonary capillary pressures (mPCP). 4. Additionally, during slow swimming (20-25m/min) the mPAP and/or PCP were higher than during supine cycling outside water at a 100W load. 5. In CHF patients, neck- deep immersion resulted in a decrease or no change in stroke volume. 6. Although patients are hemodynamically compromised, they usually maintain a feeling of well-being during aquatic therapy. Based on these findings, clinical indications for aquatic therapies are proposed and ideas are presented to provoke further research.
The impact of contextualization on immersion in healthcare simulation.
Engström, Henrik; Andersson Hagiwara, Magnus; Backlund, Per; Lebram, Mikael; Lundberg, Lars; Johannesson, Mikael; Sterner, Anders; Maurin Söderholm, Hanna
2016-01-01
The aim of this paper is to explore how contextualization of a healthcare simulation scenarios impacts immersion, by using a novel objective instrument, the Immersion Score Rating Instrument. This instrument consists of 10 triggers that indicate reduced or enhanced immersion among participants in a simulation scenario. Triggers refer to events such as jumps in time or space (sign of reduced immersion) and natural interaction with the manikin (sign of enhanced immersion) and can be used to calculate an immersion score. An experiment using a randomized controlled crossover design was conducted to compare immersion between two simulation training conditions for prehospital care: one basic and one contextualized. The Immersion Score Rating Instrument was used to compare the total immersion score for the whole scenario, the immersion score for individual mission phases, and to analyze differences in trigger occurrences. A paired t test was used to test for significance. The comparison shows that the overall immersion score for the simulation was higher in the contextualized condition. The average immersion score was 2.17 (sd = 1.67) in the contextualized condition and -0.77 (sd = 2.01) in the basic condition ( p < .001). The immersion score was significantly higher in the contextualized condition in five out of six mission phases. Events that might be disruptive for the simulation participants' immersion, such as interventions of the instructor and illogical jumps in time or space, are present to a higher degree in the basic scenario condition; while events that signal enhanced immersion, such as natural interaction with the manikin, are more frequently observed in the contextualized condition. The results suggest that contextualization of simulation training with respect to increased equipment and environmental fidelity as well as functional task alignment might affect immersion positively and thus contribute to an improved training experience.
Publications - GMC 430 | Alaska Division of Geological & Geophysical
: Formation hardness of Hemlock Formation cores after immersion in water and oil based fracturing fluids; and mechanics: Formation hardness of Hemlock Formation cores after immersion in water and oil based fracturing Surveys Skip to content State of Alaska myAlaska My Government Resident Business in Alaska
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-25
... current from the barriers would affect a human body if immersed in the water. The NEDU final report concluded that the possible effects to a human body if immersed in the water include paralysis of body... address, an e-mail address, or a telephone number in the body of your document so that we can contact you...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-02
... current from the barriers would affect a human body if immersed in the water. The NEDU final report concluded that the possible effects to a human body if immersed in the water include paralysis of body..., an e-mail address, or a telephone number in the body of your document so that we can contact you if...
BULEM, Üreyen Kaya; KECECI, Ayse Diljin; GULDAS, Hilmi Egemen
2013-01-01
NiTi instruments have a high risk of separation due to torsional or flexural fatigue (cyclic fatigue). Chemomechanical preparation, cleaning procedures, chemical disinfection and sterilization cause the corrosion of endodontic instruments that may weaken the fracture resistance of the instruments. Objective To assess the effects of NaOCl immersion and autoclave sterilization on the cyclic fatigue resistance of ProFile, FlexMaster, Mtwo and TwistedFiles NiTi instruments (tip size 25, 0.06 taper, n=160). Material and Methods The instruments (n=10 for each subgroup) were dynamically immersed in NaOCl; immersed in NaOCl and sterilized in one autoclave cycle; 5 cycles immersed in NaOCl and sterilized in autoclave and not immersed in NaOCl and not sterilized (control group). Dynamic cyclic fatigue resistance was tested. The number of cycles to failure (NCF) were statistically analyzed (P<0.05). Results Kruskall-Wallis test indicated significant differences among the tested instruments in terms of NCF (P=0.000). The mean NCF of Mtwo (556.75) was higher than that of the Twisted File, Flexmaster and ProFile, 483.1, 376.12, 365.25, respectively. NaOCl immersion and autoclave sterilization have no effect on the NCF values of the tested instruments (P>.05). Conclusions Cyclic fatigue resistance of the tested NiTi instruments cannot be adversely affected by NaOCl immersion and autoclave sterilization. Production process (TwistedFiles) or design (Twisted Files, FlexMaster, Mtwo and ProFile) of the instruments can influence their cyclic fatigue resistance. PMID:24473715
Analogs of microgravity: head-down tilt and water immersion.
Watenpaugh, Donald E
2016-04-15
This article briefly reviews the fidelity of ground-based methods used to simulate human existence in weightlessness (spaceflight). These methods include horizontal bed rest (BR), head-down tilt bed rest (HDT), head-out water immersion (WI), and head-out dry immersion (DI; immersion with an impermeable elastic cloth barrier between subject and water). Among these, HDT has become by far the most commonly used method, especially for longer studies. DI is less common but well accepted for long-duration studies. Very few studies exist that attempt to validate a specific simulation mode against actual microgravity. Many fundamental physical, and thus physiological, differences exist between microgravity and our methods to simulate it, and between the different methods. Also, although weightlessness is the salient feature of spaceflight, several ancillary factors of space travel complicate Earth-based simulation. In spite of these discrepancies and complications, the analogs duplicate many responses to 0 G reasonably well. As we learn more about responses to microgravity and spaceflight, investigators will continue to fine-tune simulation methods to optimize accuracy and applicability. Copyright © 2016 the American Physiological Society.
A Theory of Immersion Freezing
NASA Technical Reports Server (NTRS)
Barahona, Donifan
2017-01-01
Immersion freezing is likely involved in the initiation of precipitation and determines to large extent the phase partitioning in convective clouds. Theoretical models commonly used to describe immersion freezing in atmospheric models are based on the classical nucleation theory which however neglects important interactions near the immersed particle that may affect nucleation rates. This work introduces a new theory of immersion freezing based on two premises. First, immersion ice nucleation is mediated by the modification of the properties of water near the particle-liquid interface, rather than by the geometry of the ice germ. Second, the same mechanism that leads to the decrease in the work of germ formation also decreases the mobility of water molecules near the immersed particle. These two premises allow establishing general thermodynamic constraints to the ice nucleation rate. Analysis of the new theory shows that active sites likely trigger ice nucleation, but they do not control the overall nucleation rate nor the probability of freezing. It also suggests that materials with different ice nucleation efficiency may exhibit similar freezing temperatures under similar conditions but differ in their sensitivity to particle surface area and cooling rate. Predicted nucleation rates show good agreement with observations for a diverse set of materials including dust, black carbon and bacterial ice nucleating particles. The application of the new theory within the NASA Global Earth System Model (GEOS-5) is also discussed.
Berglin, Mattias; Wynne, Kenneth J; Gatenholm, Paul
2003-01-15
Surface properties of pristine and water-aged polymeric films made of alpha,omega-dihydroxypoly(dimethylsiloxane) (PDMS) cross-linked with (heptadecafluoro-1,1,2,2-tetrahydrodecyl)triethoxysilane (FTEOS17) or tetraethoxysilane (TEOS) were investigated. The FTEOS17-cured coatings showed stable advancing and receding contact angles over a period of 3 months of water exposure, compared to a 70 degrees decrease in receding contact angle for the TEOS-cured coatings. After immersion in water, hydroxyl groups were detected on the TEOS-cured coatings with attenuated total reflection infrared spectroscopy (ATR-FT/IR). Tapping-mode atomic force microscopy (TM-AFM) on pristine FTEOS17-cured coatings showed surfaces topologies ranging from smooth and featureless to topologically complex, depending on FTEOS17 concentration. The fluorinated coatings showed a stable surface morphology after water immersion, which we believe is due to the formation of a fluorinated siliceous phase that prevented the surface reconstruction, water penetration, and hydrolysis. The smooth pristine TEOS-cured coatings showed an increased roughness with cracks and erosion pits present on the surface after water immersion.
Daniel M. Johnson; William K. Smith
2008-01-01
The high altitude spruce-fir (Abies fraseri (Pursh) Poiret.-Picea rubens Sarg.) forests of the southern Appalachian Mountains, USA, experience frequent cloud immersion. Recent studies indicate that cloud bases may have risen over the past 30 years, resulting in less frequent forest cloud immersion, and that further increases in cloud base height are...
The influence of digit size and proportions on dexterity during cold exposure.
Payne, Stephanie; Macintosh, Alison; Stock, Jay
2018-04-20
The current study investigated whether size and proportions of the hands and digits affect dexterity during severe cold exposure. As wide hands are known to lose less heat than narrow hands, and narrow digits are associated with greater dexterity, this study aimed to test whether there was a direct trade-off between dexterity and thermoregulation that shapes hand morphology. Participants (25 women, 15 men) carried out the Purdue Pegboard test before and after a 3-min ice-water immersion of the hand. Their hand length, hand width, digit lengths, and digit widths were measured using standard anthropometric methods. Wide first and third digits associated with significantly reduced dexterity after immersion relative to individuals with narrower first and third digits. Second digit width positively correlated with average digit temperature after immersion. Hand length and hand width did not influence dexterity. The current study suggests that digit width influences dexterity in cold conditions, reflecting patterns found at room temperature. Hand and digit morphology may be the product of two significant constraints on the hand: dexterity and thermoregulation. In cold conditions, hand morphology appears to be predominantly constrained by thermal stress, at the expense of dexterity. This may have important implications for interpreting the morphology of extinct and extant hominins. © 2018 Wiley Periodicals, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ohta, Shinichi, E-mail: junryuhei@yahoo.co.jp; Nitta, Norihisa; Sonoda, Akinaga
2010-08-15
This study was designed to evaluate the optimal conditions for binding cisplatin and porous gelatin particles (PGPs) and to establish in vivo drug release pharmacokinetics. PGPs were immersed in cisplatin solutions under different conditions: concentration, immersion time, and temperature. Thereafter, PGPs were washed in distilled water to remove uncombined cisplatin and were then freeze-dried. The platinum concentration (PC) in the PGPs was then measured. For the in vivo release test, 50 mg/kg of the cisplatin-conjugated PGPs was implanted subcutaneously in the abdominal region of two rabbits. PCs in the blood were measured at different time intervals. PCs significantly increased inmore » direct proportion to the concentration and immersion time (p < 0.01). Although PC increased at higher solution temperature, it was not a linear progression. For the in vivo release test, platinum was released from cisplatin-conjugated PGPs after 1 day, and the peak PC was confirmed 2 days after implantation. Platinum in the blood was detected until 7 days after implantation in one rabbit and 15 days after administration in the other rabbit. Platinum binding with PGPs increased with a higher concentration of cisplatin solution at a higher temperature over a longer duration of time. Release of cisplatin from cisplatin-conjugated PGPs was confirmed in vivo.« less
Owens, Barry M; Kitchens, Michael
2007-11-01
Using scanning electron and light microscopy, this study qualitatively evaluated the erosive potential of carbonated cola beverages as well as sports and high-energy drinks on enamel surface substrate. Beverages used in this study included: Coca Cola Classic, Diet Coke, Gatorade sports drink, Red Bull high-energy drink, and tap water (control). Extracted human permanent molars free of hypocalcification and/or caries were used in this study. The coronal portion of each tooth was removed and sectioned longitudinally from the buccal to the lingual surface. The crown sections were embedded in acrylic resin, leaving the enamel surfaces exposed. Following finishing and polishing of all surfaces, one side was covered with red nail varnish while the remaining side was exposed to individual beverage immersion for 14 days, 24 hours per day, at 37 degrees C. The specimens were evaluated for enamel surface changes using scanning electron and light microscopy. Enamel specimens exhibited visual surface changes following immersion in the test beverages with Red Bull and Gatorade revealing the most striking surface morphological changes. Specimens subjected to Coca Cola Classic and Diet Coke immersion also displayed irregular post-treatment surface morphology. As verified by microscopic evaluation, all test beverages displayed enamel dissolution in the following order: Red Bull>Gatorade>Coca-Cola Classic>Diet Coke.
40 CFR Appendix A-6 to Part 60 - Test Methods 16 through 18
Code of Federal Regulations, 2010 CFR
2010-07-01
... maintaining the probe, filter box, and connections at a temperature of at least 120 °C (248 °F). Moisture is... temperature is above 0 °C (32 °F). Alternatively, moisture may be eliminated by heating the sample line, and... (2 in.). Immerse the impingers in an ice water bath and maintain near 0 °C (32 °F). The scrubber...
40 CFR Appendix A-6 to Part 60 - Test Methods 16 through 18
Code of Federal Regulations, 2011 CFR
2011-07-01
... maintaining the probe, filter box, and connections at a temperature of at least 120 °C (248 °F). Moisture is... temperature is above 0 °C (32 °F). Alternatively, moisture may be eliminated by heating the sample line, and... (2 in.). Immerse the impingers in an ice water bath and maintain near 0 °C (32 °F). The scrubber...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jenner, Elliot; Barbier, Charlotte N; D'Urso, Brian R
Robust and easily produced Superhydrophobic surfaces are of great interest for mechanical applications, including drag reduction and MEMS. We produce novel superhydrophobic surfaces with several different coatings and tested the durability of each of these coatings with respect to long term immersion in water in order to determine the most long-lasting surface preparation. A pair of combinations of spin on polymers, surface features, and adhesion promoters was found that provide long term durability.
21 CFR 173.375 - Cetylpyridinium chloride.
Code of Federal Regulations, 2014 CFR
2014-04-01
... aqueous solution applied to raw poultry carcasses prior to immersion in a chiller, at a level not to... immersion in a chiller, the treatment will be followed by a potable water rinse of the carcass. [72 FR 67576...
Enhancing Pre-Service Teachers' Awareness to Pupils' Test-Anxiety with 3D Immersive Simulation
ERIC Educational Resources Information Center
Passig, David; Moshe, Ronit
2008-01-01
This study investigated whether participating in a 3D immersive virtual reality world simulating the experience of test-anxiety would affect preservice teachers' awareness to the phenomenon. Ninety subjects participated in this study, and were divided into three groups. The experimental group experienced a 3D immersive simulation which made…
Thermal, cardiac and adrenergic responses to repeated local cooling.
Janský, L; Matousková, E; Vávra, V; Vybíral, S; Janský, P; Jandová, D; Knízková, I; Kunc, P
2006-01-01
The aim of this study was to ascertain whether repeated local cooling induces the same or different adaptational responses as repeated whole body cooling. Repeated cooling of the legs (immersion into 12 degrees C water up to the knees for 30 min, 20 times during 4 weeks = local cold adaptation - LCA) attenuated the initial increase in heart rate and blood pressure currently observed in control subjects immersed in cold water up to the knees. After LCA the initial skin temperature decrease tended to be lower, indicating reduced vasoconstriction. Heart rate and systolic blood pressure appeared to be generally lower during rest and during the time course of cooling in LCA humans, when compared to controls. All these changes seem to indicate attenuation of the sympathetic tone. In contrast, the sustained skin temperature in different areas of the body (finger, palm, forearm, thigh, chest) appeared to be generally lower in LCA subjects than in controls (except for temperatures on the forehead). Plasma levels of catecholamines (measured 20 and 40 min after the onset of cooling) were also not influenced by local cold adaptation. Locally cold adapted subjects, when exposed to whole body cold water immersion test, showed no change in the threshold temperature for induction of cold thermogenesis. This indicates that the hypothermic type of cold adaptation, typically occurring after systemic cold adaptation, does not appear after local cold adaptation of the intensity used. It is concluded that in humans the cold adaptation due to repeated local cooling of legs induces different physiological changes than systemic cold adaptation.
Effect of Water Immersion on Dual-task Performance: Implications for Aquatic Therapy.
Schaefer, Sydney Y; Louder, Talin J; Foster, Shayla; Bressel, Eadric
2016-09-01
Much is known about cardiovascular and biomechanical responses to exercise during water immersion, yet an understanding of the higher-order neural responses to water immersion is unclear. The purpose of this study was to compare cognitive and motor performance between land and water environments using a dual-task paradigm, which served as an indirect measure of cortical processing. A quasi-experimental crossover research design is used. Twenty-two healthy participants (age = 24.3 ± 5.24 years) and a single-case patient (age = 73) with mild cognitive impairment performed a cognitive (auditory vigilance) and motor (standing balance) task separately (single-task condition) and simultaneously (dual-task condition) on land and in chest-deep water. Listening errors from the auditory vigilance task and centre of pressure (CoP) area for the balance task measured cognitive and motor performance, respectively. Listening errors for the single-task and dual-task conditions were 42% and 45% lower for the water than land condition, respectively (effect size [ES] = 0.38 and 0.55). CoP area for the single-task and dual-task conditions, however, were 115% and 164% lower on land than in water, respectively, and were lower (≈8-33%) when balancing concurrently with the auditory vigilance task compared with balancing alone, regardless of environment (ES = 0.23-1.7). This trend was consistent for the single-case patient. Participants tended to make fewer 'cognitive' errors while immersed chest-deep in water than on land. These same participants also tended to display less postural sway under dual-task conditions, but more in water than on land. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
He, Pingping; Poon, Chi Sun, E-mail: cecspoon@polyu.edu.hk; Tsang, Daniel C.W.
This paper presents a study on the use of pulverized fuel ash (PFA) to improve the water resistance of magnesium oxychloride cement (MOC). Strength retention coefficients and volume stability were tested to evaluate the water resistance of MOC, in which the addition of PFA resulted in a remarkable improvement. The characterization of hydration products before and after water immersion was carried out using quantitative X-ray diffraction (QXRD), thermogravimetric (TG), Fourier-transformed infrared spectroscopy (FTIR) and scanning electron microscope (SEM). With the Q-XRD analysis, it was shown that the addition of PFA could result in the great increase of the amount ofmore » amorphous phase during air curing. This amorphous gel was identified as a mixture of magnesium-chloride-silicate-hydrate gel (M-Cl-S-H gel) and magnesium-chloride-hydrate gel (M-Cl-H gel) by elemental mapping scanning. It suggested that PFA could not only react with MOC to form M-Cl-S-H gel, but also change the morphology of magnesium oxychloride. The generation of insoluble M-Cl-S-H gel and M-Cl-H gel and densification of the microstructure contributed to the improvement of the water resistance of MOC. The MOC mortar expanded during air curing due to the hydration of excess MgO. Water immersion led to more expansion of MOC mortar as a result of the continuously hydration of excess MgO and the formation of Mg(OH){sub 2}. Adding PFA could increase the expansion of MOC mortar during air curing, which may because the amorphous gel could remain more water and benefit to the hydration of MgO. While, the addition of PFA could decrease the expansion of cement mortar during water immersion perhaps due to the reduction of the content of excess MgO and the insoluble amorphous-gel-layer that protect the MgO from hydration. Moreover, CO{sub 2} curing could further improve the performance of the PFA-blended MOC due to the formation of a higher content of amorphous gel.« less
Biodegradable magnesium-hydroxyapatite metal matrix composites.
Witte, Frank; Feyerabend, Frank; Maier, Petra; Fischer, Jens; Störmer, Michael; Blawert, Carsten; Dietzel, Wolfgang; Hort, Norbert
2007-04-01
Recent studies indicate that there is a high demand to design magnesium alloys with adjustable corrosion rates and suitable mechanical properties. An approach to this challenge might be the application of metal matrix composite (MMC) based on magnesium alloys. In this study, a MMC made of magnesium alloy AZ91D as a matrix and hydroxyapatite (HA) particles as reinforcements have been investigated in vitro for mechanical, corrosive and cytocompatible properties. The mechanical properties of the MMC-HA were adjustable by the choice of HA particle size and distribution. Corrosion tests revealed that HA particles stabilised the corrosion rate and exhibited more uniform corrosion attack in artificial sea water and cell solutions. The phase identification showed that all samples contained hcp-Mg, Mg(17)Al(12), and HA before and after immersion. After immersion in artificial sea water CaCO3 was found on MMC-HA surfaces, while no formation of CaCO3 was found after immersion in cell solutions with and without proteins. Co-cultivation of MMC-HA with human bone derived cells (HBDC), cells of an osteoblasts lineage (MG-63) and cells of a macrophage lineage (RAW264.7) revealed that RAW264.7, MG-63 and HBDC adhere, proliferate and survive on the corroding surfaces of MMC-HA. In summary, biodegradable MMC-HA are cytocompatible biomaterials with adjustable mechanical and corrosive properties.
Microbial contamination and disinfection methods of pacifiers
NELSON, Paulo; LOUVAIN, Márcia Costa; MACARI, Soraia; LUCISANO, Marília Pacífico; da SILVA, Raquel Assed Bezerra; de QUEIROZ, Alexandra Mussolino; GATON-HERNÁNDEZ, Patrícia; da SILVA, Léa Assed Bezerra
2015-01-01
Objectives To evaluate the microbial contamination of pacifiers by Mutans Streptococci (MS) and the efficacy of different methods for their disinfection. Methods Twenty-eight children were assigned to a 4-stage changeover system with a 1-week interval. In each stage, children received a new pacifier and the parents were instructed to maintain their normal habits for 1 week. After this time, the pacifiers were subjected to the following 4 disinfection methods: spraying with 0.12% chlorhexidine solution, Brushtox® or sterile tap water, and immersion in boiling tap water for 15 minutes. Microbiological culture for MS and Scanning Electron Microscopy (SEM) were performed. The results were analyzed statistically by Friedman’s non-parametric test (a=0.05). Results The 0.12% chlorhexidine spray was statistically similar to the boiling water (p>0.05) and more effective than the Brushtox® spray and control (p<0.05). The analysis of SEM showed the formation of a cariogenic biofilm in all groups with positive culture. Conclusions Pacifiers become contaminated by MS after their use by children and should be disinfected routinely. Spraying with a 0.12% chlorhexidine solution and immersion in boiling water promoted better disinfection of the pacifiers compared with a commercial antiseptic toothbrush cleanser (Brushtox®). PMID:26537723
2012-01-01
Cyprinid herpesvirus 3 (CyHV-3), also known as Koi herpesvirus, is the etiological agent of a mortal disease in common and koi carp. Recently, we investigated the entry of CyHV-3 in carp using bioluminescence imaging and a CyHV-3 recombinant strain expressing luciferase (LUC). We demonstrated that the skin is the major portal of entry after inoculation of carp by immersion in water containing CyHV-3. While this model of infection mimics some natural conditions in which infection takes place, other epidemiological conditions could favour entry of virus through the digestive tract. Here, we investigated whether ingestion of infectious materials mediates CyHV-3 entry through the digestive tract. Carp were fed with materials contaminated with the CyHV-3 LUC recombinant (oral contamination) or immersed in water containing the virus (contamination by immersion). Bioluminescence imaging analyses performed at different times post-infection led to the following observations: (i) the pharyngeal periodontal mucosa is the major portal of entry after oral contamination, while the skin is the major portal of entry after contamination by immersion. (ii) Both modes of inoculation led to the spreading of the infection to the various organs tested. However, the timing and the sequence in which some of the organs turned positive were different between the two modes of inoculation. Finally, we compared the disease induced by the two inoculation modes. They led to comparable clinical signs and mortality rate. The results of the present study suggest that, based on epidemiological conditions, CyHV-3 can enter carp either by skin or periodontal pharyngeal mucosal infection. PMID:22276598
Three dimensional live-cell STED microscopy at increased depth using a water immersion objective
NASA Astrophysics Data System (ADS)
Heine, Jörn; Wurm, Christian A.; Keller-Findeisen, Jan; Schönle, Andreas; Harke, Benjamin; Reuss, Matthias; Winter, Franziska R.; Donnert, Gerald
2018-05-01
Modern fluorescence superresolution microscopes are capable of imaging living cells on the nanometer scale. One of those techniques is stimulated emission depletion (STED) which increases the microscope's resolution many times in the lateral and the axial directions. To achieve these high resolutions not only close to the coverslip but also at greater depths, the choice of objective becomes crucial. Oil immersion objectives have frequently been used for STED imaging since their high numerical aperture (NA) leads to high spatial resolutions. But during live-cell imaging, especially at great penetration depths, these objectives have a distinct disadvantage. The refractive index mismatch between the immersion oil and the usually aqueous embedding media of living specimens results in unwanted spherical aberrations. These aberrations distort the point spread functions (PSFs). Notably, during z- and 3D-STED imaging, the resolution increase along the optical axis is majorly hampered if at all possible. To overcome this limitation, we here use a water immersion objective in combination with a spatial light modulator for z-STED measurements of living samples at great depths. This compact design allows for switching between objectives without having to adapt the STED beam path and enables on the fly alterations of the STED PSF to correct for aberrations. Furthermore, we derive the influence of the NA on the axial STED resolution theoretically and experimentally. We show under live-cell imaging conditions that a water immersion objective leads to far superior results than an oil immersion objective at penetration depths of 5-180 μm.
NASA Technical Reports Server (NTRS)
Wingard, C. D.
2015-01-01
On International Space Station (ISS), the Urine Processor Assembly (UPA) converts human urine and flush water into potable water. The urine is acid-pretreated primarily to control microbial growth. In recent years, the sulfuric acid (H2SO4) pretreatment was believed to be largely responsible for producing salt crystals capable of plugging filters in UPA components and significantly reducing the percentage of water recovery from urine. In 2012, ISS management decided to change the acid pretreatment for urine from sulfuric to phosphoric with the goal of eliminating or minimizing formation of salt crystals. In 2013-2014, as part of the qualification of the phosphoric acid (H3PO4) formulation, samples of 12 nonmetallic materials used in UPA components were immersed for up to one year in pretreated urine and brine solutions made with the new H3PO4 formulation. Dynamic mechanical analysis (DMA) was used to measure modulus (stiffness) of the immersed samples compared to virgin control samples. Such compatibility data obtained by DMA for the H3PO4-based solutions were compared to DMA data obtained for the H2SO4-based solutions in 2002-2003.
Mahboub, Farhang; Salehsaber, Fariba; Parnia, Fereydoon; Gharekhani, Vahedeh; Kananizadeh, Yousef; Taghizadeh, Mahsa
2017-01-01
Background. The aim of the present study was to evaluate the effect of Corega and 2.5% sodium hypochlorite cleansing agents on the shear and tensile bond strengths of GC soft liner to denture base. Methods. A total of 144 samples (72 samples for tensile and 72 for shear bond strength evaluations) were prepared. The samples in each group were subdivided into three subgroups in terms of the cleansing agent used (2.5% sodium hypochlorite, Corega and distilled water [control group]). All the samples were stored in distilled water, during which each sample was immersed for 15 minutes daily in sodium hypochlorite or Corega solutions. After 20 days the tensile and shear bond strengths were determined using a universal testing machine. In addition, a stereomicroscope was used to evaluate fracture modes. Data were analyzed with one-way ANOVA, using SPSS 16. Results. The results of post hoc Tukey tests showed significant differences in the mean tensile and shear bond strength values between the sodium hypochlorite group with Corega and control groups (P=0.001 for comparison of tensile bond strengths between the sodium hypochlorite and control groups, and P<0.001 for the comparison of tensile bond strengths between the sodium hypochlorite and Corega groups and the shear bond strengths between the sodium hypochlorite and Corega groups, and sodium hypochlorite and control groups).The majority of failures were cohesive in the control and Corega groups and cohesive/adhesive in the sodium hypochlorite group. Conclusion. Immersion of soft liners in Corega will result in longevity of soft liners compared to immersion in sodium hypochlorite solution and sodium hypochlorite solution significantly decreased the tensile and shear bond strengths compared to the control and Corega groups.
Mahboub, Farhang; Salehsaber, Fariba; Parnia, Fereydoon; Gharekhani, Vahedeh; Kananizadeh, Yousef; Taghizadeh, Mahsa
2017-01-01
Background. The aim of the present study was to evaluate the effect of Corega and 2.5% sodium hypochlorite cleansing agents on the shear and tensile bond strengths of GC soft liner to denture base. Methods. A total of 144 samples (72 samples for tensile and 72 for shear bond strength evaluations) were prepared. The samples in each group were subdivided into three subgroups in terms of the cleansing agent used (2.5% sodium hypochlorite, Corega and distilled water [control group]). All the samples were stored in distilled water, during which each sample was immersed for 15 minutes daily in sodium hypochlorite or Corega solutions. After 20 days the tensile and shear bond strengths were determined using a universal testing machine. In addition, a stereomicroscope was used to evaluate fracture modes. Data were analyzed with one-way ANOVA, using SPSS 16. Results. The results of post hoc Tukey tests showed significant differences in the mean tensile and shear bond strength values between the sodium hypochlorite group with Corega and control groups (P=0.001 for comparison of tensile bond strengths between the sodium hypochlorite and control groups, and P<0.001 for the comparison of tensile bond strengths between the sodium hypochlorite and Corega groups and the shear bond strengths between the sodium hypochlorite and Corega groups, and sodium hypochlorite and control groups).The majority of failures were cohesive in the control and Corega groups and cohesive/adhesive in the sodium hypochlorite group. Conclusion. Immersion of soft liners in Corega will result in longevity of soft liners compared to immersion in sodium hypochlorite solution and sodium hypochlorite solution significantly decreased the tensile and shear bond strengths compared to the control and Corega groups. PMID:29184635
Lack of diurnal effects on periodic exercise during prolonged cold water immersion.
Doubt, T J; Smith, D J
1990-03-01
Diurnal effects on periodic exercise were examined in 8 male divers wearing passive thermal protection during whole body immersions in 5 degrees C water for periods of up to 6 h. Studies were done during the course of 5-day air saturation dives at a depth of 1.61 ATA, with immersions beginning at 1000 h (AM) and 2200 h (PM). During each hour of immersion, leg exercise was done for 3 min each at workloads of 50, 70, and 90 W. Heart rate (HR) at each workload increased uniformly with immersion time, without a change in slope of HR vs. workload. No AM or PM differences occurred. AM resting VO2 increased linearly, and to the same extent as PM, with exposure time. VO2 at 50 W also increased at the same rate as resting values. VO2 at 70 and 90 W were similar for AM and PM and did not vary significantly during the 6-h immersions. Temporal increases in exercise HR may reflect cardiac compensation of diminished plasma volume. Workloads greater than or equal to 70 W generate enough metabolic heat in this specific condition to meet the thermogenic requirement. Lack of diurnal effects on exercise variables may be due to environmental conditions suppressing circadian rhythms.
Brearley, Matt; Walker, Anthony
2015-01-01
Rapidly cooling firefighters post emergency response is likely to increase the operational effectiveness of fire services during prolonged incidents. A variety of techniques have therefore been examined to return firefighters core body temperature to safe levels prior to fire scene re-entry or redeployment. The recommendation of forearm immersion (HFI) in cold water by the National Fire and Protection Association preceded implementation of this active cooling modality by a number of fire services in North America, South East Asia and Australia. The vascularity of the hands and forearms may expedite body heat removal, however, immersion of the torso, pelvis and/or lower body, otherwise known as multi-segment immersion (MSI), exposes a greater proportion of the body surface to water than HFI, potentially increasing the rates of cooling conferred. Therefore, this review sought to establish the efficacy of HFI and MSI to rapidly reduce firefighters core body temperature to safe working levels during rest periods. A total of 38 studies with 55 treatments (43 MSI, 12 HFI) were reviewed. The core body temperature cooling rates conferred by MSI were generally classified as ideal (n = 23) with a range of ~0.01 to 0.35 °C min(-1). In contrast, all HFI treatments resulted in unacceptably slow core body temperature cooling rates (~0.01 to 0.05 °C min(-1)). Based upon the extensive field of research supporting immersion of large body surface areas and comparable logistics of establishing HFI or MSI, it is recommended that fire and rescue management reassess their approach to fireground rehabilitation of responders. Specifically, we question the use of HFI to rapidly lower firefighter core body temperature during rest periods. By utilising MSI to restore firefighter Tc to safe working levels, fire and rescue services would adopt an evidence based approach to maintaining operational capability during arduous, sustained responses. While the optimal MSI protocol will be determined by the specifics of an individual response, maximising the body surface area immersed in circulated water of up to 26 °C for 15 min is likely to return firefighter Tc to safe working levels during rest periods. Utilising cooler water temperatures will expedite Tc cooling and minimise immersion duration.
Effects of menthol application on the skin during prolonged immersion in swimmers and controls.
Botonis, P G; Geladas, N D; Kounalakis, S N; Cherouveim, E D; Koskolou, M D
2017-12-01
We hypothesized that menthol application on the skin would enhance vasoconstriction of subjects immersed in cool water, which would reduce heat loss and rectal temperature (Tre) cooling rate. Furthermore, it was hypothesized that this effect would be greater in individuals acclimatized to immersion in 24 °C water, such as swimmers. Seven swimmers (SW) and seven physical education students (CON) cycled at 60% VO 2 max until Tre attained 38 °C, and were then immediately immersed in stirred water maintained at 24 °C on two occasions: without (NM) and with (M; 4.6 g per 100 mL of water) whole-body skin application of menthol cream. Heart rate, Tre, proximal-distal skin temperature gradient, oxygen uptake (VO 2 ), electromyographic activity (EMG), and thermal sensation were measured. Tre reduction was similar among SW and CON in NM and CON in M (-0.71±0.31 °C in average), while it was smaller for SW in M (-0.37±0.18 °C, P < 0.01). VO 2 and heart rate were greater in M compared with NM condition (P = 0.01). SW in M exhibited a shift of the threshold for shivering, as reflected in increased VO 2 and EMG activity, toward a higher Tre compared with the other trials. Menthol application on the skin before immersion reduces heat loss, but defends Tre decline more effectively in swimmers than in non-swimmers. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Mechanism of thirst attenuation during head-out water immersion in men
NASA Technical Reports Server (NTRS)
Wada, F.; Sagawa, S.; Miki, K.; Nagaya, K.; Nakamitsu, S.; Shiraki, K.; Greenleaf, J. E.
1995-01-01
The purpose was to determine whether extracellular volume or osmolality was the major contributing factor for reduction of thirst in air and head-out water immersion in hypohydrated subjects. Eight males (19-25 yr) were subjected to thermoneutral immersion and thermoneutral air under two hydration conditions without further drinking: euhydration in water (Eu-H2O) and euhydration in air, and hypohydration in water (Hypo-H2O) and hypohydration in air (3.7% wt loss after exercise in heat). The increased thirst sensation with Hypo-H2O decreased (P < 0.05) within 10 min of immersion and continued thereafter. Mean plasma osmolality (288 +/- 1 mosmol/kgH2O) and sodium (140 +/- 1 meq/l) remained elevated, and plasma volume increased by 4.2 +/- 1.0% (P < 0.05) throughout Hypo-H2O. A sustained increase (P < 0.05) in stroke volume accompanied the prompt and sustained decrease in plasma renin activity and sustained increase (P < 0.05) in plasma atrial natriuretic peptide during Eu-H2O and Hypo-H2O. Plasma vasopressin decreased from 5.3 +/- 0.7 to 2.9 +/- 0.5 pg/ml (P < 0.05) during Hypo-H2O but was unchanged in Eu-H2O. These findings suggest a sustained stimulation of the atrial baroreceptors and reduction of a dipsogenic stimulus without major alterations of extracellular osmolality in Hypo-H2O. Thus it appears that vascular volume-induced stimuli of cardiopulmonary baroreceptors play a more important role than extracellular osmolality in reducing thirst sensations during immersion in hypohydrated subjects.
Immersion in water during labour and birth.
Cluett, Elizabeth R; Burns, Ethel; Cuthbert, Anna
2018-05-16
Water immersion during labour and birth is increasingly popular and is becoming widely accepted across many countries, and particularly in midwifery-led care settings. However, there are concerns around neonatal water inhalation, increased requirement for admission to neonatal intensive care unit (NICU), maternal and/or neonatal infection, and obstetric anal sphincter injuries (OASIS). This is an update of a review last published in 2011. To assess the effects of water immersion during labour and/or birth (first, second and third stage of labour) on women and their infants. We searched Cochrane Pregnancy and Childbirth's Trials Register, ClinicalTrials.gov and the WHO International Clinical Trials Registry Platform (ICTRP) (18 July 2017), and reference lists of retrieved trials. We included randomised controlled trials (RCTs) comparing water immersion with no immersion, or other non-pharmacological forms of pain management during labour and/or birth in healthy low-risk women at term gestation with a singleton fetus. Quasi-RCTs and cluster-RCTs were eligible for inclusion but none were identified. Cross-over trials were not eligible for inclusion. Two review authors independently assessed trials for inclusion and risk of bias, extracted data and checked them for accuracy. Two review authors assessed the quality of the evidence using the GRADE approach. This review includes 15 trials conducted between 1990 and 2015 (3663 women): eight involved water immersion during the first stage of labour; two during the second stage only; four during the first and second stages of labour, and one comparing early versus late immersion during the first stage of labour. No trials evaluated different baths/pools, or third-stage labour management. All trials were undertaken in a hospital labour ward setting, with a varying degree of medical intervention considered as routine practice. No study was carried out in a midwifery-led care setting. Most trial authors did not specify the parity of women. Trials were subject to varying degrees of bias: the intervention could not be blinded and there was a lack of information about randomisation, and whether analyses were undertaken by intention-to-treat.Immersion in water versus no immersion (first stage of labour)There is probably little or no difference in spontaneous vaginal birth between immersion and no immersion (82% versus 83%; risk ratio (RR) 1.01, 95% confidence interval (CI) 0.97 to 1.04; 6 trials; 2559 women; moderate-quality evidence); instrumental vaginal birth (14% versus 12%; RR 0.86, 95% CI 0.70 to 1.05; 6 trials; 2559 women; low-quality evidence); and caesarean section (4% versus 5%; RR 1.27, 95% CI 0.91 to 1.79; 7 trials; 2652 women; low-quality evidence). There is insufficient evidence to determine the effect of immersion on estimated blood loss (mean difference (MD) -14.33 mL, 95% CI -63.03 to 34.37; 2 trials; 153 women; very low-quality evidence) and third- or fourth-degree tears (3% versus 3%; RR 1.36, 95% CI 0.85 to 2.18; 4 trials; 2341 women; moderate-quality evidence). There was a small reduction in the risk of using regional analgesia for women allocated to water immersion from 43% to 39% (RR 0.91, 95% CI 0.83 to 0.99; 5 trials; 2439 women; moderate-quality evidence). Perinatal deaths were not reported, and there is insufficient evidence to determine the impact on neonatal intensive care unit (NICU) admissions (6% versus 8%; average RR 1.30, 95% CI 0.42 to 3.97; 2 trials; 1511 infants; I² = 36%; low-quality evidence), or on neonatal infection rates (1% versus 1%; RR 2.00, 95% CI 0.50 to 7.94; 5 trials; 1295 infants; very low-quality evidence).Immersion in water versus no immersion (second stage of labour)There were no clear differences between groups for spontaneous vaginal birth (97% versus 99%; RR 1.02, 95% CI 0.96 to 1.08; 120 women; 1 trial; low-quality evidence); instrumental vaginal birth (2% versus 2%; RR 1.00, 95% CI 0.06 to 15.62; 1 trial; 120 women; very low-quality evidence); caesarean section (2% versus 1%; RR 0.33, 95% CI 0.01 to 8.02; 1 trial; 120 women; very low-quality evidence), and NICU admissions (11% versus 9%; RR 0.78, 95% CI 0.38 to 1.59; 2 trials; 291 women; very low-quality evidence). Use of regional analgesia was not relevant to the second stage of labour. Third- or fourth-degree tears, and estimated blood loss were not reported in either trial. No trial reported neonatal infection but did report neonatal temperature less than 36.2°C at birth (9% versus 9%; RR 0.98, 95% CI 0.30 to 3.20; 1 trial; 109 infants; very low-quality evidence), greater than 37.5°C at birth (6% versus 15%; RR 2.62, 95% CI 0.73 to 9.35; 1 trial; 109 infants; very low-quality evidence), and fever reported in first week (5% versus 2%; RR 0.53, 95% CI 0.10 to 2.82; 1 trial; 171 infants; very low-quality evidence), with no clear effect between groups being observed. One perinatal death occurred in the immersion group in one trial (RR 3.00, 95% CI 0.12 to 72.20; 1 trial; 120 infants; very low-quality evidence). The infant was born to a mother with HIV and the cause of death was deemed to be intrauterine infection.There is no evidence of increased adverse effects to the baby or woman from either the first or second stage of labour.Only one trial (200 women) compared early and late entry into the water and there were insufficient data to show any clear differences. In healthy women at low risk of complications there is moderate to low-quality evidence that water immersion during the first stage of labour probably has little effect on mode of birth or perineal trauma, but may reduce the use of regional analgesia. The evidence for immersion during the second stage of labour is limited and does not show clear differences on maternal or neonatal outcomes intensive care. There is no evidence of increased adverse effects to the fetus/neonate or woman from labouring or giving birth in water. Available evidence is limited by clinical variability and heterogeneity across trials, and no trial has been conducted in a midwifery-led setting.
Laonapakul, Teerawat; Rakngarm Nimkerdphol, Achariya; Otsuka, Yuichi; Mutoh, Yoshiharu
2012-11-01
Four point bending tests with acoustic emission (AE) monitoring were conducted for evaluating failure behavior of the plasma-sprayed hydroxyapatite (HAp) top coat on commercially pure titanium (cp-Ti) plate with and without mixed HAp/Ti bond coat. Effect of immersion in simulated body fluid (SBF) on failure behavior of the coated specimen was also investigated by immersing the specimen in SBF. The AE patterns obtained from the bending test of the HAp coating specimens after a week immersion in SBF clearly showed the earlier stage of delamination and spallation of the coating layer compared to those without immersion in SBF. It was also found that the bond coating improved failure resistance of the HAp coating specimen compared to that without the bond coat. Four point bend fatigue tests under ambient and SBF environments were also conducted with AE monitoring during the entire fatigue test for investigating the influence of SBF environment on fatigue failure behavior of the HAp coating specimen with the mixed HAp/Ti bond coat. The specimens tested at a stress amplitude of 120 MPa under both ambient and SBF environments could survive up to 10⁷ cycles without spallation of HAp coating layer. The specimens tested under SBF environment and those tested under ambient environment after immersion in SBF showed shorter fatigue life compared to those tested under ambient environment without SBF immersion. Micro-cracks nucleated in the coating layer in the early stage of fatigue life and then propagated into the cp-Ti substrate in the intermediate stage, which unstably propagated to failure in the final stage. It was found from the XRD analysis that the dissolution of the co-existing phases and the precipitation of the HAp phase were taken place during immersion in SBF. During this process, the co-existing phases disappeared from the coating layer and the HAp phase fully occupied the coating layer. The degradation of bending strength and fatigue life of the HAp coating specimens tested under SBF environment would be induced by dissolution of the co-existing phases from the coating layer during immersion in SBF. Copyright © 2012 Elsevier Ltd. All rights reserved.
The ALIVE Project: Astronomy Learning in Immersive Virtual Environments
NASA Astrophysics Data System (ADS)
Yu, K. C.; Sahami, K.; Denn, G.
2008-06-01
The Astronomy Learning in Immersive Virtual Environments (ALIVE) project seeks to discover learning modes and optimal teaching strategies using immersive virtual environments (VEs). VEs are computer-generated, three-dimensional environments that can be navigated to provide multiple perspectives. Immersive VEs provide the additional benefit of surrounding a viewer with the simulated reality. ALIVE evaluates the incorporation of an interactive, real-time ``virtual universe'' into formal college astronomy education. In the experiment, pre-course, post-course, and curriculum tests will be used to determine the efficacy of immersive visualizations presented in a digital planetarium versus the same visual simulations in the non-immersive setting of a normal classroom, as well as a control case using traditional classroom multimedia. To normalize for inter-instructor variability, each ALIVE instructor will teach at least one of each class in each of the three test groups.
Chromium(III) and chromium(VI) release from leather during 8 months of simulated use
Lidén, Carola
2016-01-01
Summary Background Chromium (Cr) release from Cr‐tanned leather articles is a major cause of Cr contact dermatitis. It has been suggested that Cr(VI) release from leather is not necessarily an intrinsic property of the leather, but is strongly dependent on environmental conditions. Objectives To test this hypothesis for long‐term (8 months) simulated use. Materials and methods The release of total Cr and Cr(VI) from Cr‐tanned, unfinished leather was analysed in subsequent phosphate buffer (pH 8.0) immersions for a period of 7.5 months. The effect of combined ultraviolet treatment and alkaline solution (pH 12.1) was tested. Dry storage [20% relative humidity (RH)] was maintained between immersions. Atomic absorption spectroscopy, X‐ray fluorescence and diphenylcarbazide tests were used. Results Cr(VI) release was dependent on previous dry storage or alkaline treatment, but not on duration or number of previous immersions. Cr(III) release decreased with time. Fifty‐two percent of the total Cr released during the last immersion period was Cr(VI). Cr(VI) release exceeded 9 mg/kg in all immersion periods except in the first 10‐day immersion (2.6 mg/kg). Conclusions Cr(VI) release is primarily determined by environmental factors (RH prior to immersion, solution pH, and antioxidant content). The RH should be kept low prior to testing Cr(VI) release from leather. PMID:27144948
NASA Astrophysics Data System (ADS)
Sari, Shaimah Rinda; Sari, Eli Novita; Rizky, Yoel; Sulistijono, Triana, Yunita
2018-05-01
This research studied the inhibition of corrosion by bawang dayak leaves extract (EleutherineamericanaMerr.) on API 5L steel in brine water environment (3.5% NaCl). The inhibitor was extracted using maceration process from bawang dayak leaves that was cultivated in Paser District, East Kalimantan. The test of antioxidant activity showed that bawang dayak leaves extract is a very powerful antioxidant with IC50 value of 27.30204. The results from FTIR test show the presence of electronegative atoms and double bonds of the alkenes groups that provide the potential of the extract as a corrosion inhibitor. Efficiency of inhibition reached up to 93.158% for the addition of inhibitor with 300 ppm concentration and 20 days of immersion time. This inhibitory behavior is also supported by polarization measurements where the lowest corrosion rate of 0.00128 mm/year is obtained at the same concentration and immersion time.
AN OSMOTIC SYSTEM WITHIN THE CYTOPLASM OF CELLS
Opie, Eugene L.
1948-01-01
The cytoplasm of cells of the liver and of the kidney is in large part occupied by bodies which respond to the water content of these cells and are modified by dissolved substances in the surrounding fluid or by physical change such as freezing. These bodies, in part mitochondria but designated more broadly cytochondria, constitute an osmotic system within the cytoplasm of cells. When the specific gravity of liver or kidney tissue is used as an index of changes in the water content of tissue, swelling of cytochondria in general follows the intake of water but this relation may be modified by a variety of conditions. When liver that has been frozen and thawed is immersed in water, cytochondria become swollen though the containing cells diminish in size. Solutions of sodium and of potassium chloride isotonic with blood plasma cause delayed swelling of cells and cytochondria, greater with the potassium salt; solutions of calcium chloride of equal molar concentration cause immediate swelling of cells and cytochondria. The basophile material of the cytoplasm (ribonucleic acid and related substances) and the material that gives to mitochondria their characteristic stain are removed by immersion in water but their disappearance is retarded by isotonic solutions of sodium or of potassium chloride and further delayed by hypertonic solutions. When the intensity of staining reactions is diminished by the partial loss of basophile substance or of the distinctive mitochondrial material, these are found at the surfaces of the cytoplasmic bodies, held perhaps by adsorption. When water, isotonic solutions of sodium chloride, or Ringer's solution comes into contact with immersed liver, they remove basophile and mitochondrial material from a superficial zone and substances with similar staining reactions appear in the cytoplasm of cells at a deeper level. Osmotic changes in the cytoplasmic bodies may be reversible. When liver tissue which has been for a short time immersed in water is transferred to a solution that is approximately isotonic in relation to blood plasma, swollen cytochondria return in part or completely to their former size; but with continued immersion in water, this reversibility becomes increasingly less complete. PMID:18912893
Effects of water-aging on self-healing dental composite containing microcapsules.
Wu, Junling; Weir, Michael D; Melo, Mary Anne S; Strassler, Howard E; Xu, Hockin H K
2016-04-01
The objectives of this study were to develop a self-healing dental composite containing poly(urea-formaldehyde) (PUF) shells with triethylene glycol dimethacrylate (TEGDMA) and N,N-dihydroxyethyl-p-toluidine (DHEPT) as healing liquid, and to investigate the mechanical properties of the composite and its self-healing efficacy after water-aging for 6 months. PUF microspheres were synthesized encapsulating a TEGDMA-DHEPT healing liquid. Composite containing 30% of a resin matrix and 70% of glass fillers by mass was incorporated with 0%, 2.5%, 5%, 7.5% and 10% of microcapsules. A flexural test was used to measure flexural strength and elastic modulus. A single edge V-notched beam method was used to measure fracture toughness (KIC) and self-healing efficacy. Specimens were water-aged at 37 °C for 1 day to 6 months and then tested for self-healing. Fractured specimens were healed while being immersed in water to examine self-healing efficacy, in comparison with that in air. Incorporation of up to 7.5% of microcapsules into the resin composite achieved effective self-healing, without adverse effects on the virgin mechanical properties of the composite (p>0.1). An excellent self-healing efficacy of 64-77% recovery was obtained (mean±sd; n=6). Six months of water-aging did not decrease the self-healing efficacy compared to 1 day (p>0.1). Exposure to water did not decrease the healing efficacy, compared to that healed in air (p>0.1). A composite was developed with excellent self-healing efficacy even while being immersed in water. The self-healing efficacy did not decrease with increasing water-aging time for 6 months. The novel self-healing composite may be promising for dental applications to heal cracks, resist fracture, and increase the durability and longevity. Copyright © 2016 Elsevier Ltd. All rights reserved.
Effects of water-aging on self-healing dental composite containing microcapsules
Wu, Junling; Weir, Michael D.; Melo, Mary Anne S.; Strassler, Howard E.; Xu, Hockin H. K.
2016-01-01
Objectives The objectives of this study were to develop a self-healing dental composite containing poly(urea-formaldehyde) (PUF) shells with triethylene glycol dimethacrylate (TEGDMA) and N,N-dihydroxyethyl-p-toluidine (DHEPT) as healing liquid, and to investigate the mechanical properties of the composite and its self-healing efficacy after water-aging for 6 months. Methods PUF microspheres were synthesized encapsulating a TEGDMA-DHEPT healing liquid. Composite containing 30% of a resin matrix and 70% of glass fillers by mass was incorporated with 0%, 2.5%, 5%, 7.5% and 10% of microcapsules. A flexural test was used to measure flexural strength and elastic modulus. A single edge V-notched beam method was used to measure fracture toughness (KIC) and self-healing efficacy. Specimens were water-aged at 37 °C for 1 d to 6 months and then tested for self-healing. Fractured specimens were healed while being immersed in water to examine self-healing efficacy, in comparison with that in air. Results Incorporation of up to 7.5% of microcapsules into the resin composite achieved effective self-healing, without adverse effects on the virgin mechanical properties of the composite (p > 0.1). An excellent self-healing efficacy of 64%–77% recovery was obtained (mean ± sd; n = 6). Six months of water-aging did not decrease the self-healing efficacy compared to 1 d (p > 0.1). Exposure to water did not decrease the healing efficacy, compared to that healed in air (p > 0.1). Conclusions A composite was developed with excellent self-healing efficacy even while being immersed in water. The self-healing efficacy did not decrease with increasing water-aging time for 6 months. Clinical significance The novel self-healing composite may be promising for dental applications to heal cracks, resist fracture, and increase the durability and longevity. PMID:26808158
Laupu, W; Brimacombe, J
2007-08-01
We tested the hypothesis that supplementary cleaning using potassium permanganate 8 mg.l(-1) eliminates protein deposits from the reusable metallic and synthetic rubber airway equipment. Twenty Macintosh laryngoscope blades (surgical steel), 20 pairs of Magill's forceps (surgical steel) and 20 Guedel airways (synthetic rubber) were allocated to two groups for supplementary cleaning. In group A, the device was immersed in potassium permanganate 8 mg.l(-1). In group B (controls), the device was immersed in sterile water. The devices were then immersed in a protein staining solution, rinsed and the severity of staining was scored. In addition, the devices were inspected for tissue and then tested for occult blood. Protein contamination was lower in the potassium permanganate group for all devices (each device: p < 0.0001). There was no staining detected in the permanganate group. In the permanganate group, dried tissue was detected in the teeth of one pair of forceps, which was not detected following supplementary cleaning. Additionally, occult blood was detected on two pairs of forceps and a laryngoscope blade, which was not detected following supplementary cleaning. In the control group, no tissue was detected but one pair of forceps and two laryngoscope blades tested positive for occult blood before and after supplementary cleaning. We conclude that supplementary cleaning using potassium permanganate 8 mg.l(-1) eliminates protein deposits from re-usable metallic and synthetic rubber airway equipment.
Mechanisms of Resistance in Microbial Spores
1990-12-20
solids (and water) content by immersion refractometry . Heat-activated spores of Bacillus stearotherrnophilus were found to be separable into two...incrC· ment of bacterial cells, enabling determination of their solids content by immersion refractometry . The results agreed well with values for
Pedroso, Lauana Borges; Barreto, Luma Franciélle Cabreira; Miotti, Leonardo Lamberti; Nicoloso, Gabriel Ferreira; Durand, Leticia Brandão
2016-01-01
This study evaluated the influence of surface sealants on the color stability of 2 different composite resins after immersion in coffee. Four groups were created (n = 10): microhybrid composite, microhybrid with surface sealant, nanofilled composite, and nanofilled composite with surface sealant. Half of the specimens of each group were immersed in distilled water and half were immersed in coffee for 48 hours. Color was measured before and after immersion. Groups with surface sealants presented less color variation when compared with the groups without surface sealants. The nanofilled resin specimens presented the greatest color variation within the groups without sealant. The surface sealant positively influenced the color stability of composite resin specimens immersed in coffee. When surface sealant was not applied, the microhybrid specimens had better color stability than the nanofilled.
Theoretical Properties of Acoustical Speckle Interferometry.
1980-09-01
an obvious one , since it was first performed in the acoustical holography. An acoustical speckle interferometry study has been demonstrated to be a...experiments in which pulses were used to study the propagation of the circumferential waves on aluminum cylinders immersed in water. In 1969, Bunney...destructive Testing SB. ABTRACT aCdo as revers. NW ass a" Id by block numb") Acoustical speckle interferometry is based locally on the elastodynamic response
Nitrogen Uptake During Air Diving
1994-03-10
of Naval Research D T IC Submitted by: ELECTE F G Hall Hypo/ Hyperbaric Center MAR2 3 199411 Duke University Medical Center D FDurham, North Carolina...physiological responses to the stresses of hypo/ hyperbaric exposure. While the evidence suggests that decompression pain is associated with small volumes of N2 in...one year of testing as per protocol for exposure to hyperbaric pressure. Body fat measurements were performed by water immersion which incorporated
Evaluation of sanitizers for inactivating Salmonella on in-shell pecans and pecan nutmeats.
Beuchat, Larry R; Mann, David A; Alali, Walid Q
2012-11-01
Chlorine, organic acids, and water extracts of inedible pecan components were tested for effectiveness in killing Salmonella on pecans. In-shell pecans and nutmeats (U.S. Department of Agriculture medium pieces) were immersion inoculated with a mixture of five Salmonella serotypes, dried to 3.7% moisture, and stored at 4°C for 3 to 6 weeks. In-shell nuts were immersed in chlorinated water (200, 400, and 1,000 μg/ml), lactic acid (0.5, 1, and 2%), and levulinic acid (0.5, 1, and 2%) with and without 0.05% sodium dodecyl sulfate (SDS), and a mixed peroxyacid sanitizer (Tsunami 200, 40 μg/ml) for up to 20 min at 21°C. The rate of reduction of free chlorine in conditioning water decreased as the ratio of in-shell nuts/water was increased. The rate of reduction was more rapid when nuts were not precleaned before treatment. The initial population of Salmonella on in-shell nuts (5.9 to 6.3 log CFU/g) was reduced by 2.8 log CFU/g after treating with chlorinated water (1,000 μg/ml). Treatment with 2% lactic acid plus SDS or 2% levulinic acid plus SDS reduced the pathogen by 3.7 and 3.4 log CFU/g, respectively. Lactic and levulinic acids (2%) without SDS were less effective (3.3- and 2.1-log CFU/g reductions, respectively) than acids with SDS. Treatment with Tsunami 200 resulted in a 2.4-log CFU/g reduction. In-shell nuts and nutmeats were immersed in water extracts of ground pecan shucks (hulls), shells, a mixture of shells and pith, and pith. The general order of lethality of extracts to Salmonella was shuck < shell-pith ≤ shell ≤ pith < chlorine (400 μg/ml) and shuck < shell ≤ pith = shell-pith < chlorine (400 μg/ml). Results emphasize the importance of removing soil and dust on in-shell pecans before conditioning in chlorinated water and the need for sanitizers with increased effectiveness in killing Salmonella on pecans.
Vetrano, Stephen J; Lebowitz, Jeffery B; Marcus, Steven
2002-11-01
Lionfish (Pterois volitans) are venomous fish most often found as aquarium pets throughout the United States. Lionfish envenomations frequently occur on the upper extremities, with pain as the predominant symptom. Immersing the injured part in warm (45 degrees C) water is considered the first and foremost important treatment as it is reported to relieve pain and inactivate the venom. Other methods of analgesia are discussed. We present a case of lionfish envenomation that failed to respond to warm water immersion.
Adepoju, Mary A; Omitoyin, Bamidele O; Mohan, Chitradurga O; Zynudheen, Aliyam A
2017-05-01
The difference in the heating penetration characteristics of product processed in retort by steam-air application and water immersion was studied. Fresh milkfish ( Chanos chanos ) packed in dry pack and in oil medium, both in flexible pouches, was thermal processed to minimum F 0 value of 7.77 at 121.1°C. Heat penetration values were recorded for each minute of processing with the aid Ellab (TM 9608, Denmark) temperature recorder. Retort come up time to achieve 121.1°C was observed to be less in steam-air which invariably led to a lower Ball's process time (B) and the total process time (T) observed in steam-air as compared to water immersion. Obtained data were plotted on a semi-logarithmic paper with temperature deficit on x -axis against time on the y -axis.
Roberts, Llion A; Raastad, Truls; Markworth, James F; Figueiredo, Vandre C; Egner, Ingrid M; Shield, Anthony; Cameron-Smith, David; Coombes, Jeff S; Peake, Jonathan M
2015-01-01
Abstract We investigated functional, morphological and molecular adaptations to strength training exercise and cold water immersion (CWI) through two separate studies. In one study, 21 physically active men strength trained for 12 weeks (2 days per week), with either 10 min of CWI or active recovery (ACT) after each training session. Strength and muscle mass increased more in the ACT group than in the CWI group (P < 0.05). Isokinetic work (19%), type II muscle fibre cross-sectional area (17%) and the number of myonuclei per fibre (26%) increased in the ACT group (all P < 0.05), but not the CWI group. In another study, nine active men performed a bout of single-leg strength exercises on separate days, followed by CWI or ACT. Muscle biopsies were collected before and 2, 24 and 48 h after exercise. The number of satellite cells expressing neural cell adhesion molecule (NCAM) (10−30%) and paired box protein (Pax7) (20−50%) increased 24–48 h after exercise with ACT. The number of NCAM+ satellite cells increased 48 h after exercise with CWI. NCAM+- and Pax7+-positive satellite cell numbers were greater after ACT than after CWI (P < 0.05). Phosphorylation of p70S6 kinaseThr421/Ser424 increased after exercise in both conditions but was greater after ACT (P < 0.05). These data suggest that CWI attenuates the acute changes in satellite cell numbers and activity of kinases that regulate muscle hypertrophy, which may translate to smaller long-term training gains in muscle strength and hypertrophy. The use of CWI as a regular post-exercise recovery strategy should be reconsidered. Key points Cold water immersion is a popular strategy to recover from exercise. However, whether regular cold water immersion influences muscle adaptations to strength training is not well understood. We compared the effects of cold water immersion and active recovery on changes in muscle mass and strength after 12 weeks of strength training. We also examined the effects of these two treatments on hypertrophy signalling pathways and satellite cell activity in skeletal muscle after acute strength exercise. Cold water immersion attenuated long term gains in muscle mass and strength. It also blunted the activation of key proteins and satellite cells in skeletal muscle up to 2 days after strength exercise. Individuals who use strength training to improve athletic performance, recover from injury or maintain their health should therefore reconsider whether to use cold water immersion as an adjuvant to their training. PMID:26174323
Investigation of melamine derived quaternary as ammonium salt potential shale inhibitor
NASA Astrophysics Data System (ADS)
Yu, Hongjiang; Hu, Weimin; Guo, Gang; Huang, Lei; Li, Lili; Gu, Xuefan; Zhang, Zhifang; Zhang, Jie; Chen, Gang
2017-06-01
Melamine, sodium chloroacetate and sodium hydroxide were used as raw materials to synthesize a kind of neutral quaternary ammonium salt (NQAS) as potential clay swelling inhibitor and water-based drilling fluid additive, and the reaction conditions were screened based on the linear expansion rate of bentonite. The inhibitive properties of NQASs were investigated by various methods, including montmorillonite (MMT) linear expansion test, mud ball immersing test, particle distribution measurement, thermogravimetric analysis and scanning electron microscopy etc. The results indicate that NQAS can inhibit expansion and dispersion of clay in water effectively. At the same condition, the bentonite linear expansion rate in NQAS-6 solution is much lower than those of others, and the hydration expansion degree of the mud ball in 0.5% NQAS-6 solution is appreciably weaker than the control test. The compatibility test indicates NQAS-6 could be compatible with the conventional additives in water-based drilling fluids, and the temperature resistance of modified starch was improved effectively. Meanwhile, the inhibitive mechanism was discussed through the particle distribution measurement.
Nondestructive Biophysical Probes of the Basis and Mechanism of Resistance in Microbial Spores.
1983-05-10
correlated with their water content, wet density, and protoplast/sporoplast volume ratio; (2) photometric immersion refractometry was used to show that the...immersion refractometry was used to determine if dehydration of the protoplast accounts for sporal resistance to heat. These and other approaches...in above). c. Gerhardt, P., T.C. Beaman, T.R. Corner, J.T. Greenamayer and L.S. Tisa. 1981. Photometric immersion Refractometry of Bacterial Spores
Birth, Bath, and Beyond: The Science and Safety of Water Immersion During Labor and Birth
Harper, Barbara
2014-01-01
The 2014 objection to birth in water voiced by both the American Academy of Pediatrics and the American College of Obstetricians and Gynecologists (ACOG) in ACOG Bulletin #594 on immersion in water during labor and birth is nothing new. The Committee on Fetus and Newborn published the very same opinion in 2005, based on a case report that was published in 2002 in the journal Pediatrics. What has changed since 2002 is a growing body of evidence that reports on the safety and efficacy of labor and birth in water. This article reviews the retrospective literature on water birth and explains newborn physiology and the protective mechanisms that prevent babies from breathing during a birth in water. PMID:25364216
Thermodynamic and Dynamic Aspects of Ice Nucleation
NASA Technical Reports Server (NTRS)
Barahona, Donifan
2018-01-01
It is known that ice nucleating particles (INP) immersed within supercooled droplets promote the formation of ice. Common theoretical models used to represent this process assume that the immersed particle lowers the work of ice nucleation without significantly affecting the dynamics of water in the vicinity of the particle. This is contrary to evidence showing that immersed surfaces significantly affect the viscosity and diffusivity of vicinal water. To study how this may affect ice formation this work introduces a model linking the ice nucleation rate to the modification of the dynamics and thermodynamics of vicinal water by immersed particles. It is shown that INP that significantly reduce the work of ice nucleation also pose strong limitations to the growth of the nascent ice germs. This leads to the onset of a new ice nucleation regime, called spinodal ice nucleation, where the dynamics of ice germ growth instead of the ice germ size determines the nucleation rate. Nucleation in this regime is characterized by an enhanced sensitivity to particle area and cooling rate. Comparison of the predicted ice nucleation rate against experimental measurements for a diverse set of species relevant to cloud formation suggests that spinodal ice nucleation may be common in nature.
Mechanical parameters and flight phase characteristics in aquatic plyometric jumping.
Louder, Talin J; Searle, Cade J; Bressel, Eadric
2016-09-01
Plyometric jumping is a commonly prescribed method of training focused on the development of reactive strength and high-velocity concentric power. Literature suggests that aquatic plyometric training may be a low-impact, effective supplement to land-based training. The purpose of the present study was to quantify acute, biomechanical characteristics of the take-off and flight phase for plyometric movements performed in the water. Kinetic force platform data from 12 young, male adults were collected for counter-movement jumps performed on land and in water at two different immersion depths. The specificity of jumps between environmental conditions was assessed using kinetic measures, temporal characteristics, and an assessment of the statistical relationship between take-off velocity and time in the air. Greater peak mechanical power was observed for jumps performed in the water, and was influenced by immersion depth. Additionally, the data suggest that, in the water, the statistical relationship between take-off velocity and time in air is quadratic. Results highlight the potential application of aquatic plyometric training as a cross-training tool for improving mechanical power and suggest that water immersion depth and fluid drag play key roles in the specificity of the take-off phase for jumping movements performed in the water.
Crippen, pilot for STS-1, during a training session
1978-03-22
S79-25014 (13 Dec. 1978) --- Astronaut Robert L. Crippen, pilot of the first space shuttle orbital flight test (STS-1), eases into a water immersion facility (WIF) during a training session in the Johnson Space Center?s training and test facility (Bldg. 260). The WIF affords one of two ways to simulate the feeling of weightlessness experienced during space extravehicular activity (EVA), the other being inside aircraft flying a parabolic curve. Crippen will be joined by astronaut John W. Young, commander for the STS-1 flight. Photo credit: NASA
Analgesic and antipyretic effects of Sansevieria trifasciata leaves.
Anbu, Jeba Sunilson J; Jayaraj, P; Varatharajan, R; Thomas, John; Jisha, James; Muthappan, M
2009-07-03
The ethanol and water extracts of Sansevieria trifasciata leaves showed dose-dependent and significant (P < 0.05) increase in pain threshold in tail-immersion test. Moreover, both the extracts (100 - 200 mg/kg) exhibited a dose-dependent inhibition of writhing and also showed a significant (P < 0.001) inhibition of both phases of the formalin pain test. The ethanol extract (200 mg/kg) significantly (P < 0.01) reversed yeast-induced fever. Preliminary phytochemical screening of the extracts showed the presence of alkaloids, flavonoids, saponins, glycosides, terpenoids, tannins, proteins and carbohydrates.
Hatim, Nadira A; Al-Tahho, Omar Zeno
2013-09-01
Evaluation of the effect of different beverages (tea with sugar, coffee with sugar, and Pepsi), and immersion time cycles (2, 4, and 12 weeks) on color change property, and dimensional change of Vertex Dental BV, Netherlands heat cured acrylic resin, recently modified Vertex Dental BV, Netherlands heat cured acrylic resin with additive (20 % banana oil), and Valplast(®) flexible resin (FR) denture base materials by using artificial saliva cycle. The total samples of this study for color, and dimensional changes were 360 samples, divided into three groups according to the type of the material, Vertex Dental BV, Netherlands heat cured acrylic resin, modified heat cured acrylic resin (Vertex with additive 20 % banana oil), and Valplast(®) FR groups, each group contains 120 samples. The thermal cycling used in this study was as follows: The samples were incubated in distilled water at 37 ± 1 °C for 2 days for conditioning. Then, the samples were immersed in beverage solutions for 10 min daily at 50 ± 1 °C temperature for tea, and coffee with sugar, while for Pepsi at 20 ± 1 °C. Then, the samples were immersed in artificial saliva at 37 ± 1 °C for 5 h, and 10 min. This cycle was repeated three times daily, and then the samples were immersed in distilled water at 22 ± 2 °C room temperature for 8 h at night. This cycle was repeated for 2, 4, and 12 weeks. At the end of each time period, the immersed samples were tested to evaluate the color change property. Descriptive statistics, ANOVA, and Duncan's multiple range tests were used to analyze the collected data. The results of this study showed that, in comparison between the materials at different times for colors L*a*b* properties, there were significant differences at P ≤ 0.05 except in color b* at 12 weeks, which showed no significant difference at P > 0.05 between materials. And there was a significant difference in dimensional change at P > 0.05 for different beverages, and times of immersion. The largest color, and dimensional changes were observed in the Valplast(®) FR, whereas tea was found to be the most chromatic agent, and showed unaccepted color change (ΔE ≤ 3.7) in vitro study as compared with coffee, Pepsi, and artificial saliva solutions.
[Disintegration of visible light-cured composite resins caused by long-term water immersion].
Hino, T; Arai, K
1989-05-01
The purpose of this study is to clarify a cause of disintegration of composite resins by long-term immersion in distilled water. Three kinds of visible light-cured composite resins (Heliosit, Plurafil Super and Visio Dispers) and one conventional composite resin (Clearfil F II) were prepared as the specimens with a 20 mm diameter and 1 mm thickness. These specimens were immersed in distilled water at 37 +/- 1 degree C for 3 years. These specimens were analysed and observed by a comprehensive multi analyzer and scanning electron microscope. The other hand residues in distilled water were analysed by infrared (IR) and nuclear magnetic resonance (NMR) spectrometers. The surface layer of all four composite resins showed signs of disintegration. The composite resins with abundant dissolved substances had disintegrated markedly, and such disintegration occurred deep inside the specimens. In IR and 1H-NMR spectra of dissolved substances, two visible light-cured composite resins (Heliosit and Plurafil Super) could be detected unreacted monomers, but one visible light-cured composite resin (Visio Dispers) and one conventional composite resin (Clearfil F II) could not be detected them. In 1H-NMR spectra of dissolved substances of all four composite resins, new signals not composed originally were observed. The progress of disintegration were demonstrated clearly. The dissolved substances were shown as the disintegrated substance between resin matrixs and silane coupling agents. It is suggested that the disintegration of composite resins by long-term water immersion is derived from hydrolysis.
Tomlinson, John J.
2006-04-18
A water-heating dehumidifier includes a refrigerant loop including a compressor, at least one condenser, an expansion device and an evaporator including an evaporator fan. The condenser includes a water inlet and a water outlet for flowing water therethrough or proximate thereto, or is affixed to the tank or immersed into the tank to effect water heating without flowing water. The immersed condenser design includes a self-insulated capillary tube expansion device for simplicity and high efficiency. In a water heating mode air is drawn by the evaporator fan across the evaporator to produce cooled and dehumidified air and heat taken from the air is absorbed by the refrigerant at the evaporator and is pumped to the condenser, where water is heated. When the tank of water heater is full of hot water or a humidistat set point is reached, the water-heating dehumidifier can switch to run as a dehumidifier.
46 CFR 160.171-25 - Production testing.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 6 2010-10-01 2010-10-01 false Production testing. 160.171-25 Section 160.171-25...: SPECIFICATIONS AND APPROVAL LIFESAVING EQUIPMENT Immersion Suits § 160.171-25 Production testing. (a) Immersion suit production testing is conducted under the procedures in this section and subpart 159.007 of this...
Relationship between mechanical properties of one-step self-etch adhesives and water sorption.
Hosaka, Keiichi; Nakajima, Masatoshi; Takahashi, Masahiro; Itoh, Shima; Ikeda, Masaomi; Tagami, Junji; Pashley, David H
2010-04-01
The purpose of this study was to evaluate the relationship between changes in the modulus of elasticity and ultimate tensile strength of one-step self-etch adhesives, and their degree of water sorption. Five one-step self-etch adhesives, Xeno IV (Dentsply Caulk), G Bond (GC Corp.), Clearfil S3 Bond (Kuraray Medical Inc.), Bond Force (Tokuyama Dental Corp.), and One-Up Bond F Plus (Tokuyama Dental Corp.) were used. Ten dumbelled-shaped polymers of each adhesive were used to obtain the modulus of elasticity by the three-point flexural bending test and the ultimate tensile strength by microtensile testing. The modulus of elasticity and the ultimate tensile strength were measured in both dry and wet conditions before/after immersion in water for 24h. Water sorption was measured, using a modification of the ISO-4049 standard. Each result of the modulus of elasticity and ultimate tensile strength was statistically analyzed using a two-way ANOVA and the result of water sorption was statistically analyzed using a one-way ANOVA. Regression analyses were used to determine the correlations between the modulus of elasticity and the ultimate tensile strength in dry or wet states, and also the percent decrease in these properties before/after immersion of water vs. water sorption. In the dry state, the moduli of elasticity of the five adhesive polymers varied from 948 to 1530 MPa, while the ultimate tensile strengths varied from 24.4 to 61.5 MPa. The wet specimens gave much lower moduli of elasticity (from 584 to 1073 MPa) and ultimate tensile strengths (from 16.5 to 35.0 MPa). Water sorption varied from 32.1 to 105.8 g mm(-3). The moduli of elasticity and ultimate tensile strengths of the adhesives fell significantly after water-storage. Water sorption depended on the constituents of the adhesive systems. The percent decreases in the ultimate tensile strengths of the adhesives were related to water sorption, while the percent reductions in the moduli of elasticity of the adhesives were not related to water sorption. Copyright (c) 2009 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Characterization of renal response to prolonged immersion in normal man
NASA Technical Reports Server (NTRS)
Epstein, M.; Denunzio, A. G.; Ramachandran, M.
1980-01-01
?jDuring the initial phase of space flight, there is a translocation of fluid from the lower parts of the body to the central vascular compartment with a resultant natriuresis, diuresis, and weight loss. Because water immersion is regarded as an appropriate model for studying the redistribution of fluid that occurs in weightlessness, an immersion study of relatively prolonged duration was carried out in order to characterize the temporal profile of the renal adaptation to central hypervolemia. Twelve normal male subjects underwent an immersion study of 8-h duration in the sodium-replete state. Immersion resulted in marked natriuresis and diuresis which were sustained throughout the immersion period. The failure of that natriuresis and diuresis of immersion to abate or cease despite marked extracellular fluid volume contraction as evidenced by a mean weight loss of -2.2 + or - 0.3 kg suggests that central blood volume was not restored to normal and that some degree of central hypervolemia probably persisted.
NASA Astrophysics Data System (ADS)
Eyu, Gaius Debi; Will, Geoffrey; Dekkers, Willem; MacLeod, Jennifer
2015-12-01
The influence of fluid flow, surface roughness and immersion time on the electrochemical behaviour of carbon steel in coal seam gas produced water under static and hydrodynamic conditions has been studied. The disc electrode surface morphology before and after the corrosion test was characterized using scanning electron microscopy (SEM). The corrosion product was examined using X-ray photoelectron spectroscopy (XPS) and X-ray diffractometry (XRD).The results show that the anodic current density increased with increasing surface roughness and consequently a decrease in corrosion surface resistance. Under dynamic flow conditions, the corrosion rate increased with increasing rotating speed due to the high mass transfer coefficient and formation of non-protective akaganeite β-FeO(OH) and goethite α-FeO(OH) corrosion scale at the electrode surface. The corrosion rate was lowest at 0 rpm. The corrosion rate decreased in both static and dynamic conditions with increasing immersion time. The decrease in corrosion rate is attributed to the deposition of corrosion products on the electrode surface. SEM results revealed that the rougher surface exhibited a great tendency toward pitting corrosion.
Evaluation of the stress corrosion cracking resistance of several high strength low alloy steels
NASA Technical Reports Server (NTRS)
Humphries, T. S.; Nelson, E. E.
1980-01-01
The stress corrosion cracking resistance was studied for high strength alloy steels 4130, 4340, for H-11 at selected strength levels, and for D6AC and HY140 at a single strength. Round tensile and C-ring type specimens were stressed up to 100 percent of their yield strengths and exposed to alternate immersion in salt water, salt spray, the atmosphere at Marshall Space Flight Center, and the seacoast at Kennedy Space Center. Under the test conditions, 4130 and 4340 steels heat treated to a tensile strength of 1240 MPa (180 ksi), H-11 and D6AC heat treated to a tensile strength of 1450 MPa (210 ksi), and HY140 (1020 MPa, 148 ksi) are resistant to stress corrosion cracking because failures were not encountered at stress levels up to 75 percent of their yield strengths. A maximum exposure period of one month for alternate immersion in salt water or salt spray and three months for seacoast is indicated for alloy steel to avoid false indications of stress corrosion cracking because of failure resulting from severe pitting.
Corbeil, Serge; McColl, Kenneth A; Williams, Lynette M; Mohammad, Ilhan; Hyatt, Alexander D; Crameri, Sandra G; Fegan, Mark; Crane, Mark St J
2012-05-01
In late 2005, acute mortalities occurred in abalone on farms located in Victoria, Australia. Disease was associated with infection by an abalone herpes virus (AbHV). Subsequently, starting in 2006, the disease (abalone viral ganglioneuritis; AVG) was discovered in wild abalone in Victorian open waters. Currently, it continues to spread, albeit at a slow rate, along the Victorian coast-line. Here, we report on experimental transmission trials that were carried out by immersion using water into which diseased abalone had shed infectious viral particles. At various time points following exposure, naïve abalone were assessed by an AbHV-specific real-time PCR and histological analyses including in situ hybridization (ISH). Results demonstrated that while exposed abalone began displaying clinical signs of the disease from 60 hours post exposure (hpe), they tested positive for the presence of viral DNA at 36 hpe. Of further interest, the AbHV DNA probe used in the ISH assay detected the virus as early as 48 hpe. Crown Copyright © 2012. Published by Elsevier B.V. All rights reserved.
Cardiovascular reflexes during rest and exercise modified by gravitational stresses
NASA Astrophysics Data System (ADS)
Bonde-petersen, Flemming
The hypotheses tested were whether variations in central venous pressure via the low pressure baroreceptors would take over or modify the arterial baroreceptor function, and further to which extent local and "whole body" hydrostatic stresses influence blood flow distribution. We investigated total forearm and skin blood flow (venous occlusion plethysmography and 133-Xe clearance) and cardiac output (rebreathing method) among other parameters. Hypo-and hypergravitational stresses were simulated by LBNP, LBPP, water immersion and lowering of the arm. The changes in flow distribution in the arm were ascribed to arterial baroreceptor function and not to low pressure baroreceptor activity. The enhancement of venous return during water immersion increased exercise tolerance during heat stress presumably due both to increased stroke volume and decreased venous pooling. The response to sustained handgrip exercise during LBNP and LBPP was not different from control measurements and the effects explained by arterial baroreceptor function. Application of exercise and local hydrostatic stresses in combination with gravitational stresses represent an interesting model for further study of the mechanisms behind the distribution of cardiac output to the peripheral organs.
NASA Astrophysics Data System (ADS)
Ru, Xiangkun; Lu, Zhanpeng; Chen, Junjie; Han, Guangdong; Zhang, Jinlong; Hu, Pengfei; Liang, Xue
2017-12-01
The iron content in Ni-Cr-xFe (x = 0-9 at.%) alloys strongly affected the properties of oxide films after 978 h of immersion in the simulated PWR primary water environment at 310 °C. Increasing the iron content in the alloys increased the amount of iron-bearing polyhedral spinel oxide particles in the outer oxide layer and increased the local oxidation penetrations into the alloy matrix from the chromium-rich inner oxide layer. The effects of iron content in the alloys on the oxide film properties after 500 h of immersion were less significant than those after 978 h. Iron content increased, and chromium content decreased, in the outer oxide layer with increasing iron content in the alloys. Increasing the immersion time facilitated the formation of the local oxidation penetrations along the matrix/film interface and the nickel-bearing spinel oxides in the outer oxide layer.
Physiologic responses to water immersion in man: A compendium of research
NASA Technical Reports Server (NTRS)
Kollias, J.; Vanderveer, D.; Dorchak, K. J.; Greenleaf, J. E.
1976-01-01
A total of 221 reports published through December 1973 in the area of physiologic responses to water immersion in man were summarized. The author's abstract or summary was used whenever possible. Otherwise, a detailed annotation was provided under the subheadings: (1) purpose, (2) procedures and methods, (3) results, and (4) conclusions. The annotations are in alphabetical order by first author; author and subject indexes are included. Additional references are provided in the selected bibliography.
Stark, Lloyd R; McLetchie, D Nicholas; Greenwood, Joshua L; Eppley, Sarah M
2016-05-01
Free-living sperm of mosses are known to be partially desiccation tolerant. We hypothesized that mature moss antheridia should also tolerate desiccation and that rehydration to partial turgor (prehydration) or rehydration to full turgor (rehydration) before immersion in water is required for full recovery from any damaging effects of prior desiccation. Bryum argenteum (silvery-thread moss) was grown in continuous culture for several months, produced mature perigonia (clusters of antheridia), and these were subjected to a slow rate of drying (∼36 h from full turgor to desiccation) and equilibration with 50% relative humidity. Perigonia were prehydrated (exposed to a saturated atmosphere) or rehydrated (planted upright in saturated media) for 0, 45, 90, 135, 180, and 1440 min, then immersed in sterile water. Time to first sperm mass release, number of antheridia releasing sperm masses, and the integrity of the first sperm mass released were assessed. Rehydration of dried antheridia for at least 3 h before immersion in water resulted in antheridia functioning similar to control undried antheridia. Compared with rehydration, prehydration was not effective in the recovery of antheridia from desiccation. For the first time, moss antheridia are shown to be fully desiccation tolerant at a functional level, capable of releasing fully functional sperm following a slow drying event provided the antheridia are allowed to rehydrate at least 3 h before immersion in water. © 2016 Botanical Society of America.
NASA Technical Reports Server (NTRS)
Greenleaf, J. E.; Silverstein, L.; Bliss, J.; Langenheim, V.; Rosson, H.; Chao, C.
1982-01-01
Water immersion and prolonged bed rest reproduce nearly all the physiological responses observed in astronauts in the weightless state. Related to actual weightlessness, given responses tend to occur sooner in immersion and later in bed rest. Much research was conducted on humans using these two techniques, especially by Russian scientists. Abstracts and annotations of reports that appeared in the literature from January 1974 through December 1980 are compiled and discussed.
Florian, John P; Simmons, Erin E; Chon, Ki H; Faes, Luca; Shykoff, Barbara E
2013-11-01
The physiological responses to water immersion (WI) are known; however, the responses to stress following WI are poorly characterized. Ten healthy men were exposed to three physiological stressors before and after a 6-h resting WI (32-33°C): 1) a 2-min cold pressor test, 2) a static handgrip test to fatigue at 40% of maximum strength followed by postexercise muscle ischemia in the exercising forearm, and 3) a 15-min 70° head-up-tilt (HUT) test. Heart rate (HR), systolic and diastolic blood pressure (SBP and DBP), cardiac output (Q), limb blood flow (BF), stroke volume (SV), systemic and calf or forearm vascular resistance (SVR and CVR or FVR), baroreflex sensitivity (BRS), and HR variability (HRV) frequency-domain variables [low-frequency (LF), high-frequency (HF), and normalized (n)] were measured. Cold pressor test showed lower HR, SBP, SV, Q, calf BF, LFnHRV, and LF/HFHRV and higher CVR and HFnHRV after than before WI (P < 0.05). Handgrip test showed no effect of WI on maximum strength and endurance and lower HR, SBP, SV, Q, and calf BF and higher SVR and CVR after than before WI (P < 0.05). During postexercise muscle ischemia, HFnHRV increased from baseline after WI only, and LFnHRV was lower after than before WI (P < 0.05). HUT test showed lower SBP, DBP, SV, forearm BF, and BRS and higher HR, FVR, LF/HFHRV, and LFnHRV after than before WI (P < 0.05). The changes suggest differential activation/depression during cold pressor and handgrip (reduced sympathetic/elevated parasympathetic) and HUT (elevated sympathetic/reduced parasympathetic) following 6 h of WI.
Chromium(III) and chromium(VI) release from leather during 8 months of simulated use.
Hedberg, Yolanda S; Lidén, Carola
2016-08-01
Chromium (Cr) release from Cr-tanned leather articles is a major cause of Cr contact dermatitis. It has been suggested that Cr(VI) release from leather is not necessarily an intrinsic property of the leather, but is strongly dependent on environmental conditions. To test this hypothesis for long-term (8 months) simulated use. The release of total Cr and Cr(VI) from Cr-tanned, unfinished leather was analysed in subsequent phosphate buffer (pH 8.0) immersions for a period of 7.5 months. The effect of combined ultraviolet treatment and alkaline solution (pH 12.1) was tested. Dry storage [20% relative humidity (RH)] was maintained between immersions. Atomic absorption spectroscopy, X-ray fluorescence and diphenylcarbazide tests were used. Cr(VI) release was dependent on previous dry storage or alkaline treatment, but not on duration or number of previous immersions. Cr(III) release decreased with time. Fifty-two percent of the total Cr released during the last immersion period was Cr(VI). Cr(VI) release exceeded 9 mg/kg in all immersion periods except in the first 10-day immersion (2.6 mg/kg). Cr(VI) release is primarily determined by environmental factors (RH prior to immersion, solution pH, and antioxidant content). The RH should be kept low prior to testing Cr(VI) release from leather. © 2016 The Authors. Contact Dermatitis published by John Wiley & Sons Ltd.
Saito, Kayo; Hayakawa, Tohru; Kawabata, Rihito; Meguro, Daijiro; Kasai, Kazutaka
2009-03-01
To assess the antibacterial activity and cytotoxicity of an orthodontic bonding material containing an antibacterial agent. Superbond C&B (4-methacryloxyethyl trimellitate anhydride/methyl methacrylate-tri-n-butyl borane [4-META/MMA-TBB]) resin was mixed with benzalkonium chloride (BAC) to obtain final BAC concentrations of 0.25%, 0.75%, 1.25%, 1.75%, 2.5%, and 5.0% (wt/ wt). Antibacterial activity against Streptococcus mutans and Streptococcus sobrinus was evaluated by soaking the BAC-resin in distilled water at 37 degrees C for periods of 30, 90, and 180 days. Antibacterial activity of the BAC-resin was measured by the disk diffusion method, and the inhibition zone around each sample was measured and recorded. For evaluation of cytotoxicity, BAC-resin samples were put into cell culture inserts placed above human gingival cells and were incubated at 37 degrees C for 1, 3, and 6 days. Cytotoxicity was assessed with a tetrazolium bromide reduction assay. The antibacterial activity of BAC-incorporated resin samples decreased significantly after immersion in water for 180 days, regardless of BAC concentration. The antibacterial activity of nonimmersed resin containing 0.25% or 1.75% BAC was comparable with that of 5.0% BAC-resin immersed for 180 days. In cytotoxicity tests, most cells died when exposed to resins containing 1.75%, 2.5%, and 5% BAC. No difference was observed between resins containing 0.25% and 0.75% BAC at 1, 3, and 6 days of culture. The addition of BAC to 4-META/MMA-TBB resin confers an antibacterial effect even after immersion in water, and 4-META/MMA-TBB resin containing 0.25% to 0.75% BAC has no significant cytotoxic effect.
NASA Astrophysics Data System (ADS)
Chakraverty, A. P.
2017-02-01
Glass fibre reinforced epoxy (GRE) composite meet several degrading agents like moisture and temperature while its use in real time applications in civil infrastructures. Keeping this in mind, the short beam shear (SBS) specimens of GRE composite were exposed to such laboratory created stringent environment as a combination of moisture and elevated temperature for several periods. The environments are as: immersion in distilled water coupled with 65oC as hydrothermal conditioning and an ambience containing 95% relative humidity at 60oC as hygrothermal conditioning. Moisture treated SBS specimens were subjected to 3-point bend test to reveal inter laminar shear strength (ILSS), stress/strain at rupture and modulus values with periods of exposures. The concerned sample suffered 23% of degradation in ILSS values after 120 days of hydrothermal immersion and 25% after 90 days of hygrothermal conditioning. Samples at some optimum exposing conditions of both the exposures are thermally characterized by adopting differential scanning calorimetry (DSC) test. Glass transition temperature (Tg) of such representing samples were determined from the DSC thermograms. About 8 % reduction in Tg values was observed for the GRE composite sample, expectedly, due to moisture induced matrix plasticization and swelling. The fractographs as obtained through scanning electron microscope (SEM) revealed some causes of failures indicating the prime modes of failure of the treated GRE samples with optimum duration of both the exposures.
Giti, Rashin; Vojdani, Mahroo; Abduo, Jaafar; Bagheri, Rafat
2016-06-01
Structural integrity and dimensional stability are the key factors that determine the clinical success and durability of luting cements in the oral cavity. Sorption and solubility of self-adhesive resin luting cements in food-simulating solutions has not been studied sufficiently. This study aimed to compare the sorption and solubility of 2 conventional and 2 self-adhesive resin-based luting cements immersed in four different storage media. A total of 32 disc-shaped specimens were prepared from each of four resin luting cements; seT (SDI), Panavia F (Kuraray), Clearfil SA Cement (Kuraray), and Choice 2 (Bisco). Eight specimens of each material were immersed in all tested solutions including n-heptane 97%, distilled water, apple juice, or Listerine mouth wash. Sorption and solubility were measured by weighing the specimens before and after immersion and desiccation. Data were analyzed by SPSS version 18, using two-way ANOVA and Tukey's HSD test with p≤ 0.05 set as the level of significance. There was a statistically significant interaction between the materials and solutions. The effect of media on the sorption and solubility was material-dependent. While seT showed the highest values of the sorption in almost all solutions, Choice 2 showed the least values of sorption and solubility. Immersion in apple juice caused more sorption than other solutions (p≤ 0.05). The sorption and solubility behavior of the studied cements were significantly affected by their composition and the storage media. The more hydrophobic materials with higher filler content like Choice 2 resin cement showed the least sorption and solubility. Due to their lower sorption and solubility, these types of resin-based luting cements are recommended to be used clinically.
A method for quantifying cloud immersion in a tropical mountain forest using time-lapse photography
Bassiouni, Maoya; Scholl, Martha A.; Torres-Sanchez, Angel J.; Murphy, Sheila F.
2017-01-01
Quantifying the frequency, duration, and elevation range of fog or cloud immersion is essential to estimate cloud water deposition in water budgets and to understand the ecohydrology of cloud forests. The goal of this study was to develop a low-cost and high spatial-coverage method to detect occurrence of cloud immersion within a mountain cloud forest by using time-lapse photography. Trail cameras and temperature/relative humidity sensors were deployed at five sites covering the elevation range from the assumed lifting condensation level to the mountain peaks in the Luquillo Mountains of Puerto Rico. Cloud-sensitive image characteristics (contrast, the coefficient of variation and the entropy of pixel luminance, and image colorfulness) were used with a k-means clustering approach to accurately detect cloud-immersed conditions in a time series of images from March 2014 to May 2016. Images provided hydrologically meaningful cloud-immersion information while temperature-relative humidity data were used to refine the image analysis using dew point information and provided temperature gradients along the elevation transect. Validation of the image processing method with human-judgment based classification generally indicated greater than 90% accuracy. Cloud-immersion frequency averaged 80% at sites above 900 m during nighttime hours and 49% during daytime hours, and was consistent with diurnal patterns of cloud immersion measured in a previous study. Results for the 617 m site demonstrated that cloud immersion in the Luquillo Mountains rarely occurs at the previously-reported cloud base elevation of about 600 m (11% during nighttime hours and 5% during daytime hours). The framework presented in this paper will be used to monitor at a low cost and high spatial resolution the long-term variability of cloud-immersion patterns in the Luquillo Mountains, and can be applied to ecohydrology research at other cloud-forest sites or in coastal ecosystems with advective sea fog.
Inactivation of Salmonella in Shell Eggs by Hot Water Immersion and Its Effect on Quality.
Geveke, David J; Gurtler, Joshua B; Jones, Deana R; Bigley, Andrew B W
2016-03-01
Thermal inactivation kinetics of heat resistant strains of Salmonella Enteritidis in shell eggs processed by hot water immersion were determined and the effects of the processing on egg quality were evaluated. Shell eggs were inoculated with a composite of heat resistant Salmonella Enteritidis (SE) strains PT8 C405, 2 (FSIS #OB030832), and 6 (FSIS #OB040159). Eggs were immersed in a circulating hot water bath for various times and temperatures. Come-up time of the coldest location within the egg was 21 min. SE was reduced by 4.5 log at both hot water immersion treatments of 56.7 C for 60 min and 55.6 °C for 100 min. Decimal reduction times (D-values) at 54.4, 55.6, and 56.7 °C were 51.8, 14.6, and 9.33 min, respectively. The z-value was 3.07 °C. Following treatments that resulted in a 4.5 log reduction (56.7 °C/60 min and 55.6 °C/100 min), the surviving population of SE remained static during 4 wk of refrigerated storage. After processing under conditions resulting in 4.5 log reductions, the Haugh unit and albumen height significantly increased (P < 0.01) and yolk index significantly decreased (P < 0.05). The shell dynamic stiffness significantly increased (P < 0.05), while static compression shell strength showed no significant difference (P < 0.05). Vitelline membrane strength significantly increased (P < 0.05); although, no significant difference (P < 0.05) was observed in vitelline membrane elasticity. In summary, the hot water immersion process inactivated heat resistant SE in shell eggs by 4.5 log, but also significantly affected several egg quality characteristics. Published 2016. This article is a U.S. Government work and is in the public domain in the USA.
Otani, Hidenori; Kaya, Mitsuharu; Tamaki, Akira; Watson, Phillip
2017-01-01
This study investigated the effects of exposure to pre-exercise heat stress and mental fatigue on endurance exercise capacity in a hot environment. Eight volunteers completed four cycle exercise trials at 80% maximum oxygen uptake until exhaustion in an environmental chamber maintained at 30 °C and 50% relative humidity. The four trials required them to complete a 90 min pre-exercise routine of either a seated rest (CON), a prolonged demanding cognitive task to induce mental fatigue (MF), warm water immersion at 40 °C during the last 30 min to induce increasing core temperature (WI), or a prolonged demanding cognitive task and warm water immersion at 40 °C during the last 30 min (MF + WI). Core temperature when starting exercise was higher following warm water immersion (~38 °C; WI and MF + WI) than with no water immersion (~36.8 °C; CON and MF, P < 0.001). Self-reported mental fatigue when commencing exercise was higher following cognitive task (MF and MF + WI) than with no cognitive task (CON and WI; P < 0.05). Exercise time to exhaustion was reduced by warm water immersion (P < 0.001) and cognitive task (P < 0.05). Compared with CON (18 ± 7 min), exercise duration reduced 0.8, 26.6 and 46.3% in MF (17 ± 7 min), WI (12 ± 5 min) and MF + WI (9 ± 3 min), respectively. This study demonstrates that endurance exercise capacity in a hot environment is impaired by either exposure to pre-exercise heat stress or mental fatigue, and this response is synergistically increased during combined exposure to them.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hiranuma, Naruki; Augustin-Bauditz, Stefanie; Bingemer, Heinz
Immersion freezing is the most relevant heterogeneous ice nucleation mechanism through which ice crystals are formed in mixed-phase clouds. In recent years, an increasing number of laboratory experiments utilizing a variety of instruments have examined immersion freezing activity of atmospherically relevant ice-nucleating particles. However, an intercomparison of these laboratory results is a difficult task because investigators have used different ice nucleation (IN) measurement methods to produce these results. A remaining challenge is to explore the sensitivity and accuracy of these techniques and to understand how the IN results are potentially influenced or biased by experimental parameters associated with these techniques.more » Within the framework of INUIT (Ice Nuclei Research Unit), we distributed an illite-rich sample (illite NX) as a representative surrogate for atmospheric mineral dust particles to investigators to perform immersion freezing experiments using different IN measurement methods and to obtain IN data as a function of particle concentration, temperature ( T), cooling rate and nucleation time. A total of 17 measurement methods were involved in the data intercomparison. Experiments with seven instruments started with the test sample pre-suspended in water before cooling, while 10 other instruments employed water vapor condensation onto dry-dispersed particles followed by immersion freezing. The resulting comprehensive immersion freezing data set was evaluated using the ice nucleation active surface-site density, n s, to develop a representative n s( T) spectrum that spans a wide temperature range (-37 °C < T < -11 °C) and covers 9 orders of magnitude in n s. In general, the 17 immersion freezing measurement techniques deviate, within a range of about 8 °C in terms of temperature, by 3 orders of magnitude with respect to n s. In addition, we show evidence that the immersion freezing efficiency expressed in n s of illite NX particles is relatively independent of droplet size, particle mass in suspension, particle size and cooling rate during freezing. A strong temperature dependence and weak time and size dependence of the immersion freezing efficiency of illite-rich clay mineral particles enabled the n s parameterization solely as a function of temperature. We also characterized the n s( T) spectra and identified a section with a steep slope between -20 and -27 °C, where a large fraction of active sites of our test dust may trigger immersion freezing. This slope was followed by a region with a gentler slope at temperatures below -27 °C. While the agreement between different instruments was reasonable below ~ -27 °C, there seemed to be a different trend in the temperature-dependent ice nucleation activity from the suspension and dry-dispersed particle measurements for this mineral dust, in particular at higher temperatures. For instance, the ice nucleation activity expressed in n s was smaller for the average of the wet suspended samples and higher for the average of the dry-dispersed aerosol samples between about -27 and -18 °C. Only instruments making measurements with wet suspended samples were able to measure ice nucleation above -18 °C. A possible explanation for the deviation between -27 and -18 °C is discussed. Multiple exponential distribution fits in both linear and log space for both specific surface area-based n s( T) and geometric surface area-based n s( T) are provided. These new fits, constrained by using identical reference samples, will help to compare IN measurement methods that are not included in the present study and IN data from future IN instruments.« less
Hiranuma, Naruki; Augustin-Bauditz, Stefanie; Bingemer, Heinz; ...
2015-03-06
Immersion freezing is the most relevant heterogeneous ice nucleation mechanism through which ice crystals are formed in mixed-phase clouds. In recent years, an increasing number of laboratory experiments utilizing a variety of instruments have examined immersion freezing activity of atmospherically relevant ice-nucleating particles. However, an intercomparison of these laboratory results is a difficult task because investigators have used different ice nucleation (IN) measurement methods to produce these results. A remaining challenge is to explore the sensitivity and accuracy of these techniques and to understand how the IN results are potentially influenced or biased by experimental parameters associated with these techniques.more » Within the framework of INUIT (Ice Nuclei Research Unit), we distributed an illite-rich sample (illite NX) as a representative surrogate for atmospheric mineral dust particles to investigators to perform immersion freezing experiments using different IN measurement methods and to obtain IN data as a function of particle concentration, temperature ( T), cooling rate and nucleation time. A total of 17 measurement methods were involved in the data intercomparison. Experiments with seven instruments started with the test sample pre-suspended in water before cooling, while 10 other instruments employed water vapor condensation onto dry-dispersed particles followed by immersion freezing. The resulting comprehensive immersion freezing data set was evaluated using the ice nucleation active surface-site density, n s, to develop a representative n s( T) spectrum that spans a wide temperature range (-37 °C < T < -11 °C) and covers 9 orders of magnitude in n s. In general, the 17 immersion freezing measurement techniques deviate, within a range of about 8 °C in terms of temperature, by 3 orders of magnitude with respect to n s. In addition, we show evidence that the immersion freezing efficiency expressed in n s of illite NX particles is relatively independent of droplet size, particle mass in suspension, particle size and cooling rate during freezing. A strong temperature dependence and weak time and size dependence of the immersion freezing efficiency of illite-rich clay mineral particles enabled the n s parameterization solely as a function of temperature. We also characterized the n s( T) spectra and identified a section with a steep slope between -20 and -27 °C, where a large fraction of active sites of our test dust may trigger immersion freezing. This slope was followed by a region with a gentler slope at temperatures below -27 °C. While the agreement between different instruments was reasonable below ~ -27 °C, there seemed to be a different trend in the temperature-dependent ice nucleation activity from the suspension and dry-dispersed particle measurements for this mineral dust, in particular at higher temperatures. For instance, the ice nucleation activity expressed in n s was smaller for the average of the wet suspended samples and higher for the average of the dry-dispersed aerosol samples between about -27 and -18 °C. Only instruments making measurements with wet suspended samples were able to measure ice nucleation above -18 °C. A possible explanation for the deviation between -27 and -18 °C is discussed. Multiple exponential distribution fits in both linear and log space for both specific surface area-based n s( T) and geometric surface area-based n s( T) are provided. These new fits, constrained by using identical reference samples, will help to compare IN measurement methods that are not included in the present study and IN data from future IN instruments.« less
Chao, Keh-Ping; Wang, Ping; Wang, Ya-Ting
2007-04-02
The chemical resistance of eight organic solvents in high density polyethylene (HDPE) geomembrane has been investigated using the ASTM F739 permeation method and the immersion test at different temperatures. The diffusion of the experimental organic solvents in HDPE geomembrane was non-Fickian kinetic, and the solubility coefficients can be consistent with the solubility parameter theory. The diffusion coefficients and solubility coefficients determined by the ASTM F739 method were significantly correlated to the immersion tests (p<0.001). The steady state permeation rates also showed a good agreement between ASTM F739 and immersion experiments (r(2)=0.973, p<0.001). Using a one-dimensional diffusion equation based on Fick's second law, the diffusion and solubility coefficients obtained by immersion test resulted in over estimates of the ASTM F739 permeation results. The modeling results indicated that the diffusion and solubility coefficients should be obtained using ASTM F739 method which closely simulates the practical application of HDPE as barriers in the field.
ECG during helicopter underwater escape training.
Tipton, Michael J; Gibbs, Peter; Brooks, Chris; Roiz de Sa, Dan; Reilly, Tara J
2010-04-01
Coincidental stimulation of the sympathetic and parasympathetic nervous system can cause "autonomic conflict" and consequent cardiac arrhythmias. The present study tested the hypotheses that: 1) cardiac arrhythmias would be seen in those undertaking helicopter underwater escape training (HUET); 2) the occurrence of arrhythmias in individuals could be predicted; and 3) the heart rate response to HUET would habituate with repeated runs. There were 26 male volunteers who each undertook 5 HUET submersions into water at 29.5 degrees C, with each run separated by 10 min. Each submersion included a 3-min, 40-s pre-submersion period, a 10-s submersion, and 40-s post-submersion period. Participants wore a three-lead telemetric ECG system beneath an immersion suit and underclothing. Skin temperature was measured in one participant. Each participant undertook tests to establish their autonomic function, including heart rate variability, face immersion, cold pressor test, and aerobic capacity assessment. The heart rate response to HUET was reduced by the fourth run when compared to the first run. Across all runs, 32 cardiac arrhythmias were identified (25%) in 22 different participants; all but 6 of the arrhythmias occurred just after submersion. Only aerobic fitness appeared inversely associated with the occurrence of arrhythmias. The heart rate response to HUET habituates. HUET produces cardiac arrhythmias; these are asymptomatic and probably of little clinical significance in young, fit individuals. It remains to be seen if this is the case with either an older, less fit cohort of people or in those undertaking longer breath holds in colder water.
Plasma-activated water: a new and effective alternative for duodenoscope reprocessing.
Bălan, Gheorghe G; Roşca, Irina; Ursu, Elena-Laura; Doroftei, Florica; Bostănaru, Andra-Cristina; Hnatiuc, Eugen; Năstasă, Valentin; Şandru, Vasile; Ştefănescu, Gabriela; Trifan, Anca; Mareş, Mihai
2018-01-01
Duodenoscopes have been widely used for both diagnostic and therapeutic endoscopic retrograde cholangiopancreatography procedures. Numerous outbreaks of duodenoscope-associated infections involving multidrug-resistant bacteria have recently been reported. Plasma activated water (PAW) has been widely considered an effective agent for surface decontamination and is increasingly used for disinfection of medical equipment. The aim of this study was to evaluate whether the duodenoscopes currently on market are suited for the repeated use of PAW and to test the efficacy of PAW for their disinfection. In order to evaluate the disinfection efficacy and the required time of contact, the duodenoscope samples were contaminated by immersing them in fasted-state simulated intestinal fluid containing Escherichia coli , Klebsiella pneumoniae , Acinetobacter baumannii , and Pseudomonas aeruginosa , prior to PAW exposure. In order to test the duodenoscope polymer compatibility with PAW, a challenge test was conducted by immersing the samples in PAW for 30 minutes daily for 45 consecutive days. Significant reductions in bacterial populations were achieved after 30 minutes of PAW treatment, indicating a high-level disinfection. Atomic force microscopy and scanning electron microscopy were used to demonstrate that repeated PAW treatment of duodenoscope coating polymer samples did not result in significant differences in morphological surface between the treated and untreated samples. Energy-dispersive X-ray spectroscopy analysis also showed no significant differences between the elemental composition of the duodenoscope coating polymer samples before and after repeated PAW treatment. Considering these preliminary results, PAW could be considered as a new alternative for duodenoscope reprocessing.
Borges, Ab; Caneppele, Tmf; Luz, M; Pucci, Cr; Torres, Crg
2014-01-01
PURPOSE : The aim of this study was to investigate the staining behavior of demineralized enamel infiltrated by low-viscosity resin. METHODS AND MATERIALS : Bovine enamel/dentin cylindrical samples (3 × 2 mm) were assigned into four groups (n=45) according to the enamel treatment: sound enamel (control), demineralization + artificial saliva, demineralization + daily application of 0.05% NaF, demineralization + resin infiltration (Icon, DMG). Artificial white spot lesions were produced in groups with demineralization. After the treatments, color was assessed by spectrophotometry, using the CIE L*a*b* system. The specimens (n=15) were then immersed in deionized water, red wine, or coffee for 10 minutes daily for eight days. Color was measured again, and the specimens were repolished with sandpaper discs. The final color was assessed. Data were analyzed by two-way analysis of variance and Tukey tests (α=0.05). A paired t-test was used for comparison between staining and repolishing conditions. RESULTS : There were significant differences for surface treatment and dye after staining and repolishing. Immersion in wine and coffee resulted in significantly increased color alteration (ΔE) compared with water (p=0.001). The resin-infiltrated group exhibited the highest staining values (p=0.001). The repolishing procedures resulted in significantly decreased color change. The exposure of specimens to colored solutions resulted in significant color alteration. The demineralized enamel treated with resin infiltration showed significantly higher staining than all other tested groups; however, the repolishing of the specimens minimized the staining effect.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wester, R.C.; Maibach, H.I.
1998-06-01
'The purpose of this study is to determine the bioavailability of organic solvents following dermal exposures to contaminated soil and water. Breath analysis is being used to obtain real-time measurements of volatile organics in expired air following exposure in rats and humans. Rhesus monkeys will be used as surrogates for humans in benzene exposures. The exhaled breath data is being analyzed using physiologically based pharmacokinetic (PBPK) models to determine the dermal bioavailability of organic solvents under realistic exposure conditions. The end product of this research will be a tested framework for the rapid screening of real and potential exposures whilemore » simultaneously developing physiologically based pharmacokinetic (PBPK) models to comprehensively evaluate and compare exposures to organics from either contaminated soil or water. This report summarizes work 7 months into a 3-year project. Method development has produced systems for solvent exposure from soil and water which mimic actual exposure, and for which animals and human volunteers can be safely tested. Soil exposure is generally open to the air (working the soil) while water exposure is generally immersion. For 6--8 hour test exposure, a patch has been developed where soil is contained against the skin by a non-occlusive membrane, while simultaneously allowing volatilization of test solvent to the environment (activated charcoal). The water counterpart is an occlusive glass culture dish, sealed to skin with silicone adhesive. Shorter term exposure is done by one hand immersion in a bucket containing circulating water or soil, the volunteer instructed to move fingers through the water or soil. Human volunteers and animals breathe fresh air via a new breath-inlet system that allows for continuous real-time analysis of undiluted exhaled air. The air supply system is self-contained and separated from the exposure solvent-laden environment. The system uses a Teledyne 3DQ Discovery ion trap mass spectrometer (MS/MS) equipped with an atmospheric sampling glow discharge ionization source (ASGDI). The MS/MS system provides an appraisal of individual chemical components in the breath stream in the single-digit parts-per-billion (ppb) detectable range for each of the compounds proposed for study, while maintaining linearity of response over a wide dynamic range.'« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ionita, G.; Stefanescu, I.
The nature and performance of our patented catalysts, with platinum on carbon and polytetrafluorethylene [Pt/C/PTFE] and platinum on styrenedivynilbenzene and polystyrene [Pt/STB/PS], used in a water-hydrogen isotope exchange process are presented. The behaviour of the two catalysts in tritiated water was tested by determining their physical and structural characteristics as well as the catalytic activity before and after immersion in tritiated water. The test results emphasized that the two catalysts are highly active in the hydrogen - water vapor (H{sub 2(g)}-H{sub 2}O{sub (v)}) isotopic exchange and highly stable to tritium radiation. It was discovered that Pt/SDB/PS catalyst proved to bemore » quite unstable in the hydrogen- water vapor - water (H{sub 2(g)}-H{sub 2}O{sub (v)}-H{sub 2}O{sub (1)}) isotopic exchange, while the Pt/C/PTFE catalyst was highly stable. Thus, the Pt/C/PTFE catalyst was chosen for hydrogen isotope separation by liquid hydrogen cryogenic distillation combined with water - hydrogen isotopic exchange in a demonstration scale plant. 5 refs., 8 figs., 2 tabs.« less
Pre-breakdown phenomena and discharges in a gas-liquid system
NASA Astrophysics Data System (ADS)
Tereshonok, D. V.; Babaeva, N. Yu; Naidis, G. V.; Panov, V. A.; Smirnov, B. M.; Son, E. E.
2018-04-01
In this paper, we investigate pre-breakdown and breakdown phenomena in gas-liquid systems. Cavitation void formation and breakdown in bubbles immersed in liquids are studied numerically, while complete breakdown of bubbled water is studied in experiments. It is shown that taking into account the dependence of water dielectric constant on electric field strength plays the same important role for cavitation void appearance under the action of electrostriction forces as the voltage rise time. It is also shown that the initial stage of breakdown in deformed bubbles immersed in liquid strongly depends on spatial orientation of the bubbles relative to the external electric field. The effect of immersed microbubbles, distributed in bulk water, on breakdown time and voltage is studied experimentally. At the breakdown voltage, the slow ‘thermal’ mechanism is changed by the fast ‘streamer-leader’ showing a decrease in breakdown time by two orders of magnitude by introducing microbubbles (0.1% of volumetric gas content) into the water. In addition, the plasma channel is found to pass between nearby microbubbles, exhibiting some ‘guidance’ effect.
Flores, Diego Rafael Martins; Brasil, Carla Cristina Bauermann; Campagnol, Paulo Cezar Bastianello; Jacob-Lopes, Eduardo; Zepka, Leila Queiroz; Wagner, Roger; Menezes, Cristiano Ragagnin; Barin, Juliano Smanioto; Flores, Erico Marlon Moraes; Cichoski, Alexandre José
2018-07-01
The initial objective of the study was to evaluate different operation modes (sweep and normal) and frequencies (25 and 130 kHz) of ultrasound in pre-chilling of breast chicken cylinders (BCC) immersed in water at 10 °C during 10 min. The second objective was to study the effect of the immersion time (5, 10, 15, 20, and 30 min) using the best operation mode and frequency obtained in the pre-chilling of the BCC in water at 10 °C. Pre-chilling was evaluated in both stages by infrared thermography, and the percentages of water absorption were determined in the second stage. The application of US at 130 kHz and normal operation mode provided a reduction of temperature on the surface of BBC higher (≈19.6%) than untreated samples. Also, compared to control, the US-treated samples in these conditions presented a more uniform cooling rate (≈22.3%) and higher water absorption (≈113%). Copyright © 2018 Elsevier Ltd. All rights reserved.
Wigner, E.P.; Ohlinger, L.A.; Young, G.J.; Weinberg, A.M.
1957-10-22
A reactor which utilizes fissionable fuel elements in rod form immersed in a moderator or heavy water and a means of circulating the heavy water so that it may also function as a coolant to remove the heat generated by the fission of the fuel are described. In this design, the clad fuel elements are held in vertical tubes immersed in heavy water in a tank. The water is circulated in a closed system by entering near the tops of the tubes, passing downward through the tubes over the fuel elements and out into the tank, where it is drawn off at the bottom, passed through heat exchangers to give up its heat and then returned to the tops of the tubes for recirculation.
Prediction of mechanical property loss in polyamide during immersion in sea water
NASA Astrophysics Data System (ADS)
Le Gac, Pierre Yves; Arhant, Mael; Le Gall, Maelenn; Burtin, Christian; Davies, Peter
2016-05-01
It is well known that the water absorption in polyamide leads to a large reduction in the mechanical properties of the polymer, which is induced by the plasticization of the amorphous phase. However, predicting such a loss in a marine environment is not straightforward, especially when thick samples are considered. This study presents a modeling study of the water absorption in polyamide 6 based on the free volume theory. Using this modeling coupled with a description of the stress yield changes with Tg, it is possible to predict the long term behavior of thick samples when immersed in sea water. Reliability of the prediction is checked by a comparison with experimental results.
An Application of Cartesian-Grid and Volume-of-Fluid Methods to Numerical Ship Hydrodynamics
2007-10-01
water-particle ve- locity is discontinuous across the air-water interface, and where CiEA is the Levi - Civita function. rj is the moment the vertical...methods and volume-of- immersed- body and volume-of-fluid (VOF) methods. fluid methods is used to simulate breaking waves around The governing equations are...of a ship hull is used as input to automat- body -fitted grids. The sole geometric input into NFA ically generate an immersed-boundary representation of
Strategies for Providing Low-Cost Water Immersion Therapy With Limited Resources.
Brickhouse, Brenda; Isaacs, Christine; Batten, Meghann; Price, Amber
At our university-affiliated medical center, a major renovation of the women's health and birthing unit resulted in the temporary loss of the permanent tub used for water immersion therapy during labor. Because 40 percent of the women in the nurse-midwifery practice utilize hydrotherapy, we undertook a rigorous search for an interim solution. We developed a safe and cost-effective strategy that can be easily replicated and utilized by others to provide hydrotherapy for laboring women. © 2015 AWHONN.
Wolf, M B; Garner, R P
1997-01-01
A model was developed of transient changes in metabolic heat production and core temperature for humans subjected to cold conditions. It was modified to predict thermal effects of the upper parts of the body being sprayed with water from a system designed to reduce the smoke effects of an airplane fire. Temperature changes were computed at 25 body segments in response to water immersion, cold-air exposure, and windy conditions. Inputs to the temperature controller were: (a) temperature change signals from skin segments and (b) an integrated signal of the product of skin and head-core (hypothalamic) temperature changes. The controller stimulated changes in blood flow to skin and muscle and heat production by shivering. Two controller parameters were adjusted to obtain good predictions of temperature and heat-production experimental data in head-out, water-immersion (0 degree-28 degrees C) studies in humans. A water layer on the skin whose thickness decreased transiently due to evaporation was added to describe the effects of the water-spray system. Because the layer evaporated rapidly in a very cold and windy environment, its additional cooling effect over a 60-min exposure period was minimal. The largest additional decrease in rectal temperature due to the water layer was < 1 degree C, which was in normal conditions where total decreases were small.
Granot, Michal; Weissman-Fogel, Irit; Crispel, Yonathan; Pud, Dorit; Granovsky, Yelena; Sprecher, Elliot; Yarnitsky, David
2008-05-01
Descending modulation of pain can be demonstrated psychophysically by dual pain stimulation. This study evaluates in 31 healthy subjects the association between parameters of the conditioning stimulus, gender and personality, and the endogenous analgesia (EA) extent assessed by diffuse noxious inhibitory control (DNIC) paradigm. Contact heat pain was applied as the test stimulus to the non-dominant forearm, with stimulation temperature at a psychophysical intensity score of 60 on a 0-100 numerical pain scale. The conditioning stimulus was a 60s immersion of the dominant hand in cold (12, 15, 18 degrees C), hot (44 and 46.5 degrees C), or skin temperature (33 degrees C) water. The test stimulus was repeated on the non-dominant hand during the last 30s of the conditioning immersion. EA extent was calculated as the difference between pain scores of the two test stimuli. State and trait anxiety and pain catastrophizing scores were assessed prior to stimulation. EA was induced only for the pain-generating conditioning stimuli at 46.5 degrees C (p=0.011) and 12 degrees C (p=0.003). EA was independent of conditioning pain modality, or personality, but a significant gender effect was found, with greater EA response in males. Importantly, pain scores of the conditioning stimuli were not correlated with EA extent. The latter is based on both our study population, and on additional 82 patients, who participated in another study, in which EA was induced by immersion at 46.5 degrees C. DNIC testing, thus, seems to be relatively independent of the stimulation conditions, making it an easy to apply tool, suitable for wide range applications in pain psychophysics.
Savabi, Omid; Nejatidanesh, Farahnaz; Bagheri, Kamran Poshang; Karimi, Leila; Savabi, Ghazal
2018-01-01
Disinfection of dental impression is mandatory for preventing the cross infection between dental staff and dental laboratory. Ozone as a disinfectant can be used in various ways in dentistry. The aim of this study was to evaluate the efficacy of ozonated water for disinfection of irreversible hydrocolloid impression materials and preventing cross-contamination. Thirty-two circular specimens (1 cm diameter and 2 mm thickness) of irreversible hydrocolloid impression material were made. Thirty specimens were contaminated with Pseudomonas aeruginosa (ATCC 27853), Staphylococcus aureus (ATCC 51299), and Candida albicans (PTCC 5027). Except control samples ( n = 2), the other specimens were immersed in ozonated water for 5 and 10 min (5 sample each group). Trypsin was used for separating microorganisms. Diluted microbial solution was analyzed microbiologically for colony-forming units (CFUs). Two-way repeated measure ANOVA and Scheffe post hoc test were used for data analysis (α = 0.05). The number of CFUs after disinfection with ozonated water was decreased significantly (11.84%, 61.55%, and 20.27% after 5 min and 11.03%, 14.50%, and 16.99% after 10 min for P. aeruginosa , S. aureus , and C. albicans , respectively) ( P < 0.001). Increasing the time of disinfection resulted in significant reduction in a number of S. aureus only ( P < 0.001) although they did not vanish microorganisms completely. Immersion of irreversible hydrocolloid impression material in ozonated water for 10 min will not lead to complete disinfection but decreases the microorganisms to a level that can prevent infection transmission.
Sheikh-Al-Eslamian, Seyedeh Mahsa; Hasani, Elham; Abrandabadi, Ahmad Najafi
2016-01-01
We aimed to evaluate the color stability of bulk-fill and conventional composite resin with respect to thickness and storage media. Twenty specimens of a conventional composite resin (6 mm diameter and 2 mm thick) and 40 specimens of the bulk-fill Tetric EvoCeram composite resin at two different thicknesses (6 mm diameter and 2 mm thick or 4 mm thick, n = 20) were prepared. The specimens were stored in distilled water during the study period (28 d). Half of the specimens were remained in distilled water and the other half were immersed in coffee solution 20 min/d and kept in distilled water between the cycles. Color changes (ΔE) were measured using the CIE L ⁎ a ⁎ b ⁎ color space and a digital imaging system at 1, 7, 14, and 28 days of storage. Data were analyzed using Two-way ANOVA and Tukey's HSD post hoc test (P < 0.05). Composite resins showed significant increase in color changes by time (bulk-fill > conventional; P < 0.001). Coffee exhibited significantly more staining susceptibility than that of distilled water (P < 0.001). There was greater color changes with increasing the increment thickness, which was significant at 14 (P < 0.001) and 28 d (P < 0.01). Color change of bulk-fill composite resin was greater than that of the conventional one after coffee staining and is also a function of increment thicknesses. PMID:27403163
Effects of water immersion on renal hemodynamics in normal man
NASA Technical Reports Server (NTRS)
Epstein, M.; Levinson, R.; Loutzenhiser, R.
1976-01-01
The present study was undertaken to delineate the effects of water immersion to the neck (NI) on renal plasma flow and glomerular filtration rate as assessed by the clearance of p-aminohippuric acid (PAH) and inulin, respectively. Nine normal male subjects were studied on two occasions, control and NI. The conditions of seated posture and time of day were identical. Immersion did not alter either clearance at a time when sodium excretion was increasing markedly. The constancy of PAH clearance during NI suggests that renal blood flow is unaltered and that the natriuresis of NI is mediated independently of alterations in overall renal perfusion. The sluggish decline of a natriuresis during recovery is consistent with the presence of a humoral factor contributing to the encountered natriuresis.
Spina, Denis Roberto Falcão; Grossi, João Ricardo Almeida; Cunali, Rafael Schlögel; Baratto Filho, Flares; da Cunha, Leonardo Fernandes; Gonzaga, Carla Castiglia; Correr, Gisele Maria
2015-01-01
The aim of this study was to evaluate the discoloration effects of water, cola-based soft drink, coffee, and wine on resin composites used in restorative dentistry and the possibility of removing the stain with chair side manual polishing. The A2 shade of three materials was tested. Disc specimens were prepared. A spectrophotometer was used to measure the baseline CIE-Lab color parameters of each material (n=10) 24 hours after sample preparation. Samples were then immersed in a cola-based soft drink, coffee, or wine for 1 hour every day, for 30 days. For the remaining hours, the specimens were stored in distilled water. In the control group, the specimens were immersed in water for the whole period. The color differences (ΔE) were calculated after 7 and 30 days of storage, and after polishing with coarse Sof-Lex discs, and analyzed by two-way ANOVA with repeated measures and Tukey's HSD test (α=0.05). Luna presented higher ΔE values (3.41)a followed by Durafill (2.82)b and Herculite (2.24)c. For the drink solutions, ΔE values were higher for wine (4.40)a followed by coffee (2.59)b and for cola-based soft drink (2.23)c and water (2.13)c which were statistically similar. For time, ΔE values were higher for 30 days (3.97)a and then for 7 days (2.48)b and after polishing (2.04)c. The results indicate that color stability is material dependent. The types of drinks that patients consume also influence the color stability of restorative materials. PMID:27347551
Guevara-López, Uriah; Gutiérrez-Sougarret, Bernardo; López-Pavón, Lucy; Aldrete, J Antonio; Tamayo-Valenzuela, Antonio
2004-01-01
Neuropathic pain results from injury or impairment of the nervous system manifested by pain syndrome. Experimental models have been used to study its effects and how to suppress these. Tricyclic antidepressants (TCA) and anticonvulsant (AC) have been used for treatment. To evaluate the antihyperanalgesic efficiency of intraperitoneal (IP) chlorimipramine (CIP) vs IP phenytoine (DFH) for induced neuropathic pain in an experimental animal model. After making a surgical ligature of the sciatic nerve in the right leg of 18 male rats, the time of withdrawal of both claws immersed in hot (45 degrees C) and cold water (10 degrees C) was measured during a four week period before and after IP CIP, DFH, or placebo administered in a double blind study. Significant statistical differences were observed in the time of withdrawal with CIP as compared with DFH and when both groups were compared with placebo (as tested by the paw immersion in hot water). When the thermal stimulus was cold water, an increase of the time of withdrawal was seen with DFH. These findings suggest that CIP and FS are both effective in the treatment of neuropathic pain in an animal model, as well as for the treatment of secondary hiperalgesia.
Lorenzon, S; Giulianini, P G; Martinis, M; Ferrero, E A
2007-05-01
Homarus americanus is an important commercial species that can survive 2-3 days out of water if kept cool and humid. Once caught for commercial purpose and shipped around the world, a lobster is likely to be subjected to a number of stressors, including emersion and air exposure, hypoxia, temperature changes and handling. This study focused on the effect of transport stress and specifically at different animal body temperature (6 and 15 degrees C) and air exposure during commercial transport and recovery process in water. Animals were monitored, by hemolymph bleeding, at different times: 0 h (arrival time at plant) 3 h, 12 h, 24 h and 96 h after immersion in the stocking tank with a water temperature of 6.5+/-1.5 degrees C. We analysed the effects by testing some physiological variables of the hemolymph: glucose, cHH, lactate, total protein, cholesterol, triglycerides, chloride and calcium concentration, pH and density. All these variables appeared to be influenced negatively by high temperature both in average of alteration from the physiological value and in recovering time. Blood glucose, lactate, total protein, cholesterol were significantly higher in the group with high body temperature compared to those with low temperature until 96 h after immersion in the recovery tank.
NASA Astrophysics Data System (ADS)
Fernandez-Saldivar, J.; Culfaz, F.; Angli, N.; Bhatti, I.; Lobb, D.; Baister, G.; Touzet, B.; Desserouer, F.; Guldimann, B.
2017-11-01
New immersed grating technology is needed particularly for use in imaging spectrometers that will be used in sensing the atmosphere O2A spectral band (750nm - 775 nm) at spectral resolution in the order of 0.1 nm whilst ensuring a high efficiency and maintaining low stray light. In this work, the efficiency, dispersion and stray light performance of an immersed grating are tested and compared to analytical models. The grating consists of an ion-beam etched grating in a fused-silica substrate of 120 mm x 120mm immersed on to a prism of the same material. It is designed to obtain dispersions > 0.30°/nm-1 in air and >70% efficiency. The optical performance of the immersed grating is modelled and methods to measure its wavefront, efficiency, dispersion and scattered radiance are described. The optical setup allows the measurement of an 80mm beam diameter to derive the bidirectional scatter distribution function (BSDF) from the immersed grating from a minimum angle of 0.1° from the diffracted beam with angular resolution of 0.05°. Different configurations of the setup allow the efficiency and dispersion measurements using a tuneable laser in the 750nm-775nm range. The results from the tests are discussed with the suitability of the immersed gratings in mind for future space based instruments for atmospheric monitoring.
Persistence of immersed blood and hair DNA: A preliminary study based on casework.
Frippiat, Christophe; Gastaldi, Agathe; Van Grunderbeeck, Séverine
2017-10-01
In some cases, evidence is collected from rivers, canals, lakes or sink pipes. To determine the utility of analyzing these samples and for cases in which DNA was recovered from submerged bulletproof vest parts, we evaluated the time necessary to degrade the blood and, subsequently, DNA on bulletproof vests. In a second experiment, also based on cases, blood was diluted in water from a kitchen sink pipe and incubated at room temperature for different times. Subsequently, DNA quality was assessed. In a parallel experiment, hair roots were incubated in spring water for different time periods. This study demonstrates that after one week of immersion of the bulletproof vest parts in a canal only one sample from more than 100 samples gave a partial genetic profile. No genetic profile were obtained for the 99 other samples. After one month immersion and despite the finding that blood remained detectable on bulletproof vest parts, no genetic profile was obtained for all samples using the classical STR approach. For longer immersion times, no genetic profiles were obtained. In sink pipe water, an incubation time of 72 h (h) was necessary before significant blood degradation occurred. Nevertheless, high inter-sample variability was observed. This high variability may be explained by the variability of water composition coming from nine different sink pipes. For hair root cells incubated in water, we observed that more than 90% of the DNA was degraded after 72 h. Copyright © 2017 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.
The interplays among technology and content, immersant and VE
NASA Astrophysics Data System (ADS)
Song, Meehae; Gromala, Diane; Shaw, Chris; Barnes, Steven J.
2010-01-01
The research program aims to explore and examine the fine balance necessary for maintaining the interplays between technology and the immersant, including identifying qualities that contribute to creating and maintaining a sense of "presence" and "immersion" in an immersive virtual reality (IVR) experience. Building upon and extending previous work, we compare sitting meditation with walking meditation in a virtual environment (VE). The Virtual Meditative Walk, a new work-in-progress, integrates VR and biofeedback technologies with a self-directed, uni-directional treadmill. As immersants learn how to meditate while walking, robust, real-time biofeedback technology continuously measures breathing, skin conductance and heart rate. The physiological states of the immersant will in turn affect the audio and stereoscopic visual media through shutter glasses. We plan to test the potential benefits and limitations of this physically active form of meditation with data from a sitting form of meditation. A mixed-methods approach to testing user outcomes parallels the knowledge bases of the collaborative team: a physician, computer scientists and artists.
Bleakley, Chris M; Davison, Gareth W
2010-02-01
Cold-water immersion (CWI) is a popular recovery intervention after exercise. The scientific rationale is not clear, and there are no clear guidelines for its use. The aim of this review was to study the physiological and biochemical effect of short periods of CWI. A computer-based literature search, citation tracking and related articles searches were undertaken. Primary research studies using healthy human participants, immersed in cold water (<15 degrees C), for 5 min durations or less were included. Data were extracted on body temperature, cardiovascular, respiratory and biochemical response. 16 studies were included. Sample size was restricted, and there was a large degree of study heterogeneity. CWI was associated with an increase in heart rate, blood pressure, respiratory minute volume and metabolism. Decreases in end tidal carbon dioxide partial pressure and a decrease in cerebral blood flow were also reported. There was evidence of increases in peripheral catecholamine concentration, oxidative stress and a possible increase in free-radical-species formation. The magnitude of these responses may be attenuated with acclimatisation. CWI induces significant physiological and biochemical changes to the body. Much of this evidence is derived from full body immersions using resting healthy participants. The physiological and biochemical rationale for using short periods of CWI in sports recovery still remains unclear.
Story Immersion in a Health Videogame for Childhood Obesity Prevention.
Lu, Amy Shirong; Thompson, Debbe; Baranowski, Janice; Buday, Richard; Baranowski, Tom
2012-02-15
Stories can serve as powerful tools for health interventions. Story immersion refers to the experience of being absorbed in a story. This is among the first studies to analyze story immersion's role in health videogames among children by addressing two main questions: Will children be more immersed when the main characters are similar to them? Do increased levels of immersion relate to more positive health outcomes? Eighty-seven 10-12-year-old African-American, Caucasian, and Hispanic children from Houston, TX, played a health videogame, "Escape from Diab" (Archimage, Houston, TX), featuring a protagonist with both African-American and Hispanic phenotypic features. Children's demographic information, immersion, and health outcomes (i.e., preference, motivation, and self-efficacy) were recorded and then correlated and analyzed. African-American and Hispanic participants reported higher immersion scores than Caucasian participants ( P = 0.01). Story immersion correlated positively ( P values < 0.03) with an increase in Fruit and Vegetable Preference ( r = 0.27), Intrinsic Motivation for Water ( r = 0.29), Vegetable Self-Efficacy ( r = 0.24), and Physical Activity Self-Efficacy ( r = 0.32). Ethnic similarity between videogame characters and players enhanced immersion and several health outcomes. Effectively embedding characters with similar phenotypic features to the target population in interactive health videogame narratives may be important when motivating children to adopt obesity prevention behaviors.
Common toads (Bufo arenarum) learn to anticipate and avoid hypertonic saline solutions.
Daneri, M Florencia; Papini, Mauricio R; Muzio, Rubén N
2007-11-01
Toads (Bufo arenarum) were exposed to pairings between immersion in a neutral saline solution (i.e., one that caused no significant variation in fluid balance), followed by immersion in a highly hypertonic saline solution (i.e., one that caused water loss). In Experiment 1, solutions were presented in a Pavlovian conditioning arrangement. A group receiving a single neutral-highly hypertonic pairing per day exhibited a greater conditioned increase in heart rate than groups receiving either the same solutions in an explicitly unpaired fashion, or just the neutral solution. Paired toads also showed a greater ability to compensate for water loss across trials than that of the explicitly unpaired group. Using the same reinforcers and a similar apparatus, Experiment 2 demonstrated that toads learn a one-way avoidance response motivated by immersion in the highly hypertonic solution. Cardiac and avoidance conditioning are elements of an adaptive system for confronting aversive situations involving loss of water balance. Copyright 2007 APA.
Gan, Hongjian; He, Haiwen; Sato, Atsushi; Hatta, Hajime; Nakao, Miki; Somamoto, Tomonori
2015-04-01
Ulcer disease, caused by atypical Aeromonas salmonicida, is a serious concern in ornamental koi carp, because it induces skin ulceration, disfiguring ornamental fish and causing economic loses. The present study aimed to establish a novel prophylaxis with chicken egg yolk immunoglobulin, IgY, against ulcer disease and to assess its feasibility in the ornamental fish industry. Addition of egg yolk powder containing anti-A. salmonicida IgY to rearing water provided significant protection against an A. salmonicida bath infection, whereas administration of non-specific IgY did not. Consecutive immersion of fish into rearing water containing specific IgY completely prevented ulcer disease resulting from cohabitation infection, indicating that this prophylaxis could prevent infection from such type of contact. Thus, passive immunization induced by immersing fish into aquarium water containing specific IgY is a prospective prophylaxis against diseases caused by pathogens that invade the skin and gills. Copyright © 2015 Elsevier Ltd. All rights reserved.
Immersion Condensation on Oil-Infused Heterogeneous Surfaces for Enhanced Heat Transfer
Xiao, Rong; Miljkovic, Nenad; Enright, Ryan; Wang, Evelyn N.
2013-01-01
Enhancing condensation heat transfer is important for broad applications from power generation to water harvesting systems. Significant efforts have focused on easy removal of the condensate, yet the other desired properties of low contact angles and high nucleation densities for high heat transfer performance have been typically neglected. In this work, we demonstrate immersion condensation on oil-infused micro and nanostructured surfaces with heterogeneous coatings, where water droplets nucleate immersed within the oil. The combination of surface energy heterogeneity, reduced oil-water interfacial energy, and surface structuring enabled drastically increased nucleation densities while maintaining easy condensate removal and low contact angles. Accordingly, on oil-infused heterogeneous nanostructured copper oxide surfaces, we demonstrated approximately 100% increase in heat transfer coefficient compared to state-of-the-art dropwise condensation surfaces in the presence of non-condensable gases. This work offers a distinct approach utilizing surface chemistry and structuring together with liquid-infusion for enhanced condensation heat transfer. PMID:23759735
NASA Astrophysics Data System (ADS)
Mobin, M.; Alam, R.; Aslam, J.
2016-07-01
A copolymer of aniline (AN) and o-anisidine (OA), Poly(AN-co-OA) and its nanocomposite with ZnO nanoparticles, Poly(AN-co-OA)/ZnO were synthesized by chemical oxidative polymerization using ammonium persulfate as an oxidant in hydrochloric acid medium. The synthesized compounds were characterized using FTIR, XRD, SEM-EDS, TEM, and electrical conductivity techniques. The copolymer and nanocomposite were separately dissolved in N-methyl-2-pyrrolidone and were casted on low-carbon steel specimens using 10% epoxy resin as a binder. The anticorrosive properties of the coatings were studied in different corrosive environments such as 0.1 M HCl, 5% NaCl solution, and distilled water at a temperature of 30 °C by conducting corrosion tests which include immersion test, open circuit potential measurements, potentiodynamic polarization measurements, and atmospheric exposure test. The surface morphology of the coatings prior to and after one-month immersion in corrosive solution was evaluated using SEM. It was observed that the nanocomposite coating exhibited higher corrosion resistance and provided better barrier properties in comparison with copolymer coating. The presence of ZnO nanoparticles improved the anticorrosion properties of copolymer coating in all corrosive media subjected to investigation.
de Oliveira, Ana Luísa Botta Martins; Botta, Ana Carolina; Campos, Juliana Álvares Duarte Bonini; Garcia, Patrícia Petromilli Nordi Sasso
2014-08-01
This study evaluated the influence of fluoride mouth rinses and repolishing on the superficial morphology and color stability of nanofilled resin. About 150 specimens were prepared and polished using aluminum oxide discs for 15 s with a pressure of 2 kg. The experimental groups were divided according to the immersion medium (artificial saliva, 0.5% sodium fluoride, Fluordent Reach, Oral B, Fluorgard) and repolishing procedure (without and with). The specimens were continuously immersed for 1 week. Thereafter, half of each sample was repolished. A color reading was performed after 24 h of immersion in the artificial saliva baseline, after continuous immersion, and after repolishing. The superficial morphology was examined using scanning electron microscopy (SEM) in a qualitative way. Color change (∆E) data were submitted to a mixed analysis of variance using a Shapiro-Wilk test (p>0.05 for the different immersion media) and Sidak's test (p<0.05 for the differences between groups). In the interaction between the repolishing and the immersion media, Fluorgard showed a statistical difference between the ∆E values with and without repolishing (p<0.0001). On the SEM observations, both Fluordent Reach and Fluorgard caused degradation of the superficial resinous matrix of the composite after continuous immersion. This matrix was removed after repolishing.
Harker, JO; Leung, JW; Siao-Salera, RM; Mann, SK; Ramirez, FC; Friedland, S; Amato, A; Radaelli, F; Paggi, S; Terruzzi, V; Hsieh, YH
2011-01-01
Introduction Variation in outcomes in RcTs comparing water-related methods and air insufflation raises challenging questions regarding the new approach. This report reviews impact of water exchange - simultaneous infusion and removal of infused water during insertion on adenoma detection rate (ADR) defined as proportion of patients with a least one adenoma of any size. Methods Medline (2008–2011) searches, abstract of 2011 Digestive Disease Week (DDW) meeting and personal communications were considered to identify RcTs that compared water-related methods and air insufflation to aid insertion of colonoscope. Results Since 2008, eleven reports of RcTs (6 published, 1 submitted and 4 abstracts, n=1728) described ADR in patients randomized to be examined by air and water-related methods. The water-related methods differed in timing of removal of the infused water -predominantly during insertion (water exchange) (n=825) or predominantly during withdrawal (water immersion) (n=903). Water immersion was associated with both increases and decreases in ADR compared to respective air method patients and the net overall change (-7%) was significant. On the other hand water exchange was associated with increases in ADR consistently and the net changes (overall, 8%; proximal overall, 11%; and proximal <10 mm, 12%) were all significant. Conclusion Comparative data generated the hypothesis that significantly larger increases in overall and proximal colon ADRs were associated with water exchange than water immersion or air insufflation during insertion. The hypothesis should be evaluated by RCTs to elucidate the mechanism of water exchange on adenoma detection. PMID:22163082