Sample records for wear simulator study

  1. Influence of hip joint simulator design and mechanics on the wear and creep of metal-on-polyethylene bearings

    PubMed Central

    Ali, Murat; Al-Hajjar, Mazen; Partridge, Susan; Williams, Sophie; Fisher, John; Jennings, Louise M

    2016-01-01

    Hip joint simulators are used extensively for preclinical testing of hip replacements. The variation in simulator design and test conditions used worldwide can affect the tribological performance of polyethylene. The aim of this study was to assess the effects of simulator mechanics and design on the wear and creep of ultra-high-molecular-weight polyethylene. In the first part of this study, an electromechanical simulator and pneumatic simulator were used to compare the wear and creep of metal-on-polyethylene components under the same standard gait conditions. In the second part of the study, the same electromechanical hip joint simulator was used to investigate the influence of kinematics on wear. Higher wear rates and penetration depths were observed from the electromechanical simulator compared with the pneumatic simulator. When adduction/abduction was introduced to the gait cycle, there was no significant difference in wear with that obtained under the gait cycle condition without adduction/abduction. This study confirmed the influence of hip simulator design and loading conditions on the wear of polyethylene, and therefore direct comparisons of absolute wear rates between different hip joint simulators should be avoided. This study also confirmed that the resulting wear path was the governing factor in obtaining clinically relevant wear rates, and this can be achieved with either two axes or three axes of rotations. However, three axes of rotation (with the inclusion of adduction/abduction) more closely replicate clinical conditions and should therefore be the design approach for newly developed hip joint simulators used for preclinical testing. PMID:27160559

  2. Influence of hip joint simulator design and mechanics on the wear and creep of metal-on-polyethylene bearings.

    PubMed

    Ali, Murat; Al-Hajjar, Mazen; Partridge, Susan; Williams, Sophie; Fisher, John; Jennings, Louise M

    2016-05-01

    Hip joint simulators are used extensively for preclinical testing of hip replacements. The variation in simulator design and test conditions used worldwide can affect the tribological performance of polyethylene. The aim of this study was to assess the effects of simulator mechanics and design on the wear and creep of ultra-high-molecular-weight polyethylene. In the first part of this study, an electromechanical simulator and pneumatic simulator were used to compare the wear and creep of metal-on-polyethylene components under the same standard gait conditions. In the second part of the study, the same electromechanical hip joint simulator was used to investigate the influence of kinematics on wear. Higher wear rates and penetration depths were observed from the electromechanical simulator compared with the pneumatic simulator. When adduction/abduction was introduced to the gait cycle, there was no significant difference in wear with that obtained under the gait cycle condition without adduction/abduction. This study confirmed the influence of hip simulator design and loading conditions on the wear of polyethylene, and therefore direct comparisons of absolute wear rates between different hip joint simulators should be avoided. This study also confirmed that the resulting wear path was the governing factor in obtaining clinically relevant wear rates, and this can be achieved with either two axes or three axes of rotations. However, three axes of rotation (with the inclusion of adduction/abduction) more closely replicate clinical conditions and should therefore be the design approach for newly developed hip joint simulators used for preclinical testing. © IMechE 2016.

  3. Can physical joint simulators be used to anticipate clinical wear problems of new joint replacement implants prior to market release?

    PubMed

    Medley, John B

    2016-05-01

    One of the most important mandates of physical joint simulators is to provide test results that allow the implant manufacturer to anticipate and perhaps avoid clinical wear problems with their new products. This is best done before market release. This study gives four steps to follow in conducting such wear simulator testing. Two major examples involving hip wear simulators are discussed in which attempts had been made to predict clinical wear performance prior to market release. The second one, involving the DePuy ASR implant systems, is chosen for more extensive treatment by making it an illustrative example to explore whether wear simulator testing can anticipate clinical wear problems. It is concluded that hip wear simulator testing did provide data in the academic literature that indicated some risk of clinical wear problems prior to market release of the ASR implant systems. This supports the idea that physical joint simulators have an important role in the pre-market testing of new joint replacement implants. © IMechE 2016.

  4. Wear Distribution Detection of Knee Joint Prostheses by Means of 3D Optical Scanners

    PubMed Central

    Affatato, Saverio; Valigi, Maria Cristina; Logozzo, Silvia

    2017-01-01

    The objective of this study was to examine total knee polyethylene inserts from in vitro simulation to evaluate and display—using a 3D optical scanner—wear patterns and wear rates of inserts exposed to wear by means of simulators. Various sets of tibial inserts have been reconstructed by using optical scanners. With this in mind, the wear behavior of fixed and mobile bearing polyethylene knee configurations was investigated using a knee wear joint simulator. After the completion of the wear test, the polyethylene menisci were analyzed by an innovative 3D optical scanners in order to evaluate the 3D wear distribution on the prosthesis surface. This study implemented a new procedure for evaluating polyethylene bearings of joint prostheses obtained after in vitro wear tests and the proposed new approach allowed quantification of the contact zone on the geometry of total knee prostheses. The results of the present study showed that mobile TKPs (total knee prosthesis) have lower wear resistance with respect to fixed TKPs. PMID:28772725

  5. A comprehensive combined experimental and computational framework for pre-clinical wear simulation of total knee replacements.

    PubMed

    Abdelgaied, A; Fisher, J; Jennings, L M

    2018-02-01

    A more robust pre-clinical wear simulation framework is required in order to simulate wider and higher ranges of activities, observed in different patient populations such as younger more active patients. Such a framework will help to understand and address the reported higher failure rates for younger and more active patients (National_Joint_Registry, 2016). The current study has developed and validated a comprehensive combined experimental and computational framework for pre-clinical wear simulation of total knee replacements (TKR). The input mechanical (elastic modulus and Poisson's ratio) and wear parameters of the moderately cross-linked ultra-high molecular weight polyethylene (UHMWPE) bearing material were independently measured from experimental studies under realistic test conditions, similar to the loading conditions found in the total knee replacements. The wear predictions from the computational wear simulation were validated against the direct experimental wear measurements for size 3 Sigma curved total knee replacements (DePuy, UK) in an independent experimental wear simulation study under three different daily activities; walking, deep squat, and stairs ascending kinematic conditions. The measured compressive mechanical properties of the moderately cross-linked UHMWPE material were more than 20% lower than that reported in the literature under tensile test conditions. The pin-on-plate wear coefficient of moderately cross-linked UHMWPE was significantly dependant of the contact stress and the degree of cross-shear at the articulating surfaces. The computational wear predictions for the TKR from the current framework were consistent and in a good agreement with the independent full TKR experimental wear simulation measurements, with 0.94 coefficient of determination of the framework. In addition, the comprehensive combined experimental and computational framework was able to explain the complex experimental wear trends from the three different daily activities investigated. Therefore, such a framework can be adopted as a pre-clinical simulation approach to optimise different designs, materials, as well as patient's specific total knee replacements for a range of activities. Copyright © 2017. Published by Elsevier Ltd.

  6. Tribological Properties of AlCrCuFeNi2 High-Entropy Alloy in Different Conditions

    NASA Astrophysics Data System (ADS)

    Liu, Yong; Ma, Shengguo; Gao, Michael C.; Zhang, Chuan; Zhang, Teng; Yang, Huijun; Wang, Zhihua; Qiao, Junwei

    2016-07-01

    In order to understand the environmental effect on the mechanical behavior of high-entropy alloys, the tribological properties of AlCrCuFeNi2 are studied systematically in dry, simulated rainwater, and deionized water conditions against the Si3N4 ceramic ball at a series of different normal loads. The present study shows that both the friction and wear rate in simulated rainwater are the lowest. The simulated rainwater plays a significant role in the tribological behavior with the effect of forming passive film, lubricating, cooling, cleaning, and corrosion. The wear mechanism in simulated rainwater is mainly adhesive wear accompanied by abrasive wear as well as corrosive wear. In contrast, those in dry condition and deionized water are abrasive wear, adhesive wear, and surface plastic deformation. Oxidation contributes to the wear behavior in dry condition but is prevented in liquid condition. In addition, the phase diagram of Al x CrCuFeNi2 is predicted using CALPHAD modeling, which is in good agreement with the literature report and the present study.

  7. 3D FEM Simulation of Flank Wear in Turning

    NASA Astrophysics Data System (ADS)

    Attanasio, Aldo; Ceretti, Elisabetta; Giardini, Claudio

    2011-05-01

    This work deals with tool wear simulation. Studying the influence of tool wear on tool life, tool substitution policy and influence on final part quality, surface integrity, cutting forces and power consumption it is important to reduce the global process costs. Adhesion, abrasion, erosion, diffusion, corrosion and fracture are some of the phenomena responsible of the tool wear depending on the selected cutting parameters: cutting velocity, feed rate, depth of cut, …. In some cases these wear mechanisms are described by analytical models as a function of process variables (temperature, pressure and sliding velocity along the cutting surface). These analytical models are suitable to be implemented in FEM codes and they can be utilized to simulate the tool wear. In the present paper a commercial 3D FEM software has been customized to simulate the tool wear during turning operations when cutting AISI 1045 carbon steel with uncoated tungsten carbide tip. The FEM software was improved by means of a suitable subroutine able to modify the tool geometry on the basis of the estimated tool wear as the simulation goes on. Since for the considered couple of tool-workpiece material the main phenomena generating wear are the abrasive and the diffusive ones, the tool wear model implemented into the subroutine was obtained as combination between the Usui's and the Takeyama and Murata's models. A comparison between experimental and simulated flank tool wear curves is reported demonstrating that it is possible to simulate the tool wear development.

  8. Effect of motion inputs on the wear prediction of artificial hip joints

    PubMed Central

    Liu, Feng; Fisher, John; Jin, Zhongmin

    2013-01-01

    Hip joint simulators have been largely used to assess the wear performance of joint implants. Due to the complexity of joint movement, the motion mechanism adopted in simulators varies. The motion condition is particularly important for ultra-high molecular weight polyethylene (UHMWPE) since polyethylene wear can be substantially increased by the bearing cross-shear motion. Computational wear modelling has been improved recently for the conventional UHMWPE used in total hip joint replacements. A new polyethylene wear law is an explicit function of the contact area of the bearing and the sliding distance, and the effect of multidirectional motion on wear has been quantified by a factor, cross-shear ratio. In this study, the full simulated walking cycle condition based on a walking measurement and two simplified motions, including the ISO standard motion and a simplified ProSim hip simulator motion, were considered as the inputs for wear modelling based on the improved wear model. Both the full simulation and simplified motions generated the comparable multidirectional motion required to reproduce the physiological wear of the bearing in vivo. The predicted volumetric wear of the ProSim simulator motion and the ISO motion conditions for the walking cycle were 13% and 4% lower, respectively, than that of the measured walking condition. The maximum linear wear depths were almost the same, and the areas of the wear depth distribution were 13% and 7% lower for the ProSim simulator and the ISO condition, respectively, compared with that of the measured walking cycle motion condition. PMID:25540472

  9. Wear simulation of resin composites and the relationship to clinical wear.

    PubMed

    Barkmeier, Wayne W; Latta, Mark A; Erickson, Robert L; Wilwerding, Terry M

    2008-01-01

    This study used a new generalized wear model to examine the relationship between wear simulation and the clinical wear of two resin composites. Ten specimens each of P50 and Z100, were subjected to 100,000, 400,000 and 800,000 cycles in a spring-loaded piston-type wear simulator. Wear was generated using flat, cylindrically-shaped stainless steel antagonists on the resin composites, which were placed in custom stainless steel fixtures. A slurry of polymethyl methacrylate beads was used as the abrasive media. Wear was determined using profilometry, and the parameters examined included volume loss (mm3), maximum depth (microm), mean maximum depth (microm) and mean depth (microm). Statistical analysis of the laboratory wear data using ANOVA and Tukey's post hoc test showed a significant difference (p<0.05) for wear between the two materials and the number of cycles. Mean maximum wear (microm) values (100K--P50--11.5 +/- 1.8; Z100--4.9 +/- 1.0; 400K--P50--17.2 +/- 2.7; Z100--6.0 +/- 1.7; 800K--P50--20.5 +/- 4.6; Z100--9.6 +/- 2.5) were used for comparisons with clinical data. Previous clinical studies of P50 and Z100 were used to examine the relationship between laboratory and clinical wear. Linear regression analysis was used to predict laboratory and clinical wear rates. The laboratory wear rate for P50 was 1.3 microm/100K cycles and the rate for Z100 was 0.7 microm/100K cycles. The clinical wear rates for P50 and Z100 were 8.3 microm/year and 4.0 microm/year, respectively. The ratio of wear rates of P50 to Z100 for wear simulation was 1.9 and the ratio of P50 to Z100 for clinical rates was 2.1. These ratios showed good agreement between the relative wear rates of laboratory and clinical wear. For the two composite materials examined, this new simulation model appears to be effective for evaluating the relative wear of resin composites.

  10. A hip joint simulator study using new and physiologically scratched femoral heads with ultra-high molecular weight polyethylene acetabular cups.

    PubMed

    Barbour, P S; Stone, M H; Fisher, J

    2000-01-01

    This study validates a hip joint simulator configuration as compared with other machines and clinical wear rates using smooth metal and ceramic femoral heads and ultra-high molecular weight polyethylene (UHMWPE) acetabular cups. Secondly the wear rate of UHMWPE cups is measured in the simulator with deliberately scratched cobalt-chrome heads to represent the type of mild and severe scratch damage found on retrieved heads. Finally, the scratching processes are described and the resulting scratches compared with those found in retrieved cobalt-chrome heads. For smooth cobalt-chrome and zirconia heads the wear rates were found to be statistically similar to other simulator machines and within the normal range found from clinical studies. An increased wear rate was found with cobalt-chrome heads scratched using either the diamond stylus or the bead cobalt-chrome but the greatest increase was with the diamond scratched heads which generated scratches of similar dimensions to those on retrieved heads. A greater than twofold increase in wear rate is reported for these heads when compared with smooth heads. This increased wear rate is, however, still within the limits of data from clinical wear studies.

  11. The influence of simulator input conditions on the wear of total knee replacements: An experimental and computational study

    PubMed Central

    Brockett, Claire L; Abdelgaied, Abdellatif; Haythornthwaite, Tony; Hardaker, Catherine; Fisher, John; Jennings, Louise M

    2016-01-01

    Advancements in knee replacement design, material and sterilisation processes have provided improved clinical results. However, surface wear of the polyethylene leading to osteolysis is still considered the longer-term risk factor. Experimental wear simulation is an established method for evaluating the wear performance of total joint replacements. The aim of this study was to investigate the influence of simulation input conditions, specifically input kinematic magnitudes, waveforms and directions of motion and position of the femoral centre of rotation, on the wear performance of a fixed-bearing total knee replacement through a combined experimental and computational approach. Studies were completed using conventional and moderately cross-linked polyethylene to determine whether the influence of these simulation input conditions varied with material. The position of the femoral centre of rotation and the input kinematics were shown to have a significant influence on the wear rates. Similar trends were shown for both the conventional and moderately cross-linked polyethylene materials, although lower wear rates were found for the moderately cross-linked polyethylene due to the higher level of cross-linking. The most important factor influencing the wear was the position of the relative contact point at the femoral component and tibial insert interface. This was dependent on the combination of input displacement magnitudes, waveforms, direction of motion and femoral centre of rotation. This study provides further evidence that in order to study variables such as design and material in total knee replacement, it is important to carefully control knee simulation conditions. This can be more effectively achieved through the use of displacement control simulation. PMID:27160561

  12. Generation of a large volume of clinically relevant nanometre-sized ultra-high-molecular-weight polyethylene wear particles for cell culture studies

    PubMed Central

    Ingham, Eileen; Fisher, John; Tipper, Joanne L

    2014-01-01

    It has recently been shown that the wear of ultra-high-molecular-weight polyethylene in hip and knee prostheses leads to the generation of nanometre-sized particles, in addition to micron-sized particles. The biological activity of nanometre-sized ultra-high-molecular-weight polyethylene wear particles has not, however, previously been studied due to difficulties in generating sufficient volumes of nanometre-sized ultra-high-molecular-weight polyethylene wear particles suitable for cell culture studies. In this study, wear simulation methods were investigated to generate a large volume of endotoxin-free clinically relevant nanometre-sized ultra-high-molecular-weight polyethylene wear particles. Both single-station and six-station multidirectional pin-on-plate wear simulators were used to generate ultra-high-molecular-weight polyethylene wear particles under sterile and non-sterile conditions. Microbial contamination and endotoxin levels in the lubricants were determined. The results indicated that microbial contamination was absent and endotoxin levels were low and within acceptable limits for the pharmaceutical industry, when a six-station pin-on-plate wear simulator was used to generate ultra-high-molecular-weight polyethylene wear particles in a non-sterile environment. Different pore-sized polycarbonate filters were investigated to isolate nanometre-sized ultra-high-molecular-weight polyethylene wear particles from the wear test lubricants. The use of the filter sequence of 10, 1, 0.1, 0.1 and 0.015 µm pore sizes allowed successful isolation of ultra-high-molecular-weight polyethylene wear particles with a size range of < 100 nm, which was suitable for cell culture studies. PMID:24658586

  13. Generation of a large volume of clinically relevant nanometre-sized ultra-high-molecular-weight polyethylene wear particles for cell culture studies.

    PubMed

    Liu, Aiqin; Ingham, Eileen; Fisher, John; Tipper, Joanne L

    2014-04-01

    It has recently been shown that the wear of ultra-high-molecular-weight polyethylene in hip and knee prostheses leads to the generation of nanometre-sized particles, in addition to micron-sized particles. The biological activity of nanometre-sized ultra-high-molecular-weight polyethylene wear particles has not, however, previously been studied due to difficulties in generating sufficient volumes of nanometre-sized ultra-high-molecular-weight polyethylene wear particles suitable for cell culture studies. In this study, wear simulation methods were investigated to generate a large volume of endotoxin-free clinically relevant nanometre-sized ultra-high-molecular-weight polyethylene wear particles. Both single-station and six-station multidirectional pin-on-plate wear simulators were used to generate ultra-high-molecular-weight polyethylene wear particles under sterile and non-sterile conditions. Microbial contamination and endotoxin levels in the lubricants were determined. The results indicated that microbial contamination was absent and endotoxin levels were low and within acceptable limits for the pharmaceutical industry, when a six-station pin-on-plate wear simulator was used to generate ultra-high-molecular-weight polyethylene wear particles in a non-sterile environment. Different pore-sized polycarbonate filters were investigated to isolate nanometre-sized ultra-high-molecular-weight polyethylene wear particles from the wear test lubricants. The use of the filter sequence of 10, 1, 0.1, 0.1 and 0.015 µm pore sizes allowed successful isolation of ultra-high-molecular-weight polyethylene wear particles with a size range of < 100 nm, which was suitable for cell culture studies.

  14. Influence of Thermal Cycling on Flexural Properties and Simulated Wear of Computer-aided Design/Computer-aided Manufacturing Resin Composites.

    PubMed

    Tsujimoto, A; Barkmeier, W W; Takamizawa, T; Latta, M A; Miyazaki, M

    The purpose of this study was to evaluate the influence of thermal cycling on the flexural properties and simulated wear of computer-aided design/computer-aided manufacturing (CAD/CAM) resin composites. The six CAD/CAM resin composites used in this study were 1) Lava Ultimate CAD/CAM Restorative (LU); 2) Paradigm MZ100 (PM); 3) CERASMART (CS); 4) Shofu Block HC (SB); 5) KATANA AVENCIA Block (KA); and 6) VITA ENAMIC (VE). Specimens were divided randomly into two groups, one of which was stored in distilled water for 24 hours, and the other of which was subjected to 10,000 thermal cycles. For each material, 15 specimens from each group were used to determine the flexural strength and modulus according to ISO 6872, and 20 specimens from each group were used to examine wear using a localized wear simulation model. The test materials were subjected to a wear challenge of 400,000 cycles in a Leinfelder-Suzuki device (Alabama machine). The materials were placed in custom-cylinder stainless steel fixtures, and simulated localized wear was generated using a stainless steel ball bearing (r=2.387 mm) antagonist in a water slurry of polymethyl methacrylate beads. Simulated wear was determined using a noncontact profilometer (Proscan 2100) with Proscan and AnSur 3D software. The two-way analysis of variance of flexural properties and simulated wear of CAD/CAM resin composites revealed that material type and thermal cycling had a significant influence (p<0.05), but there was no significant interaction (p>0.05) between the two factors. The flexural properties and maximum depth of wear facets of CAD/CAM resin composite were different (p<0.05) depending on the material, and their values were influenced (p>0.05) by thermal cycling, except in the case of VE. The volume losses in wear facets on LU, PM, and SB after 10,000 thermal cycles were significantly higher (p<0.05) than those after 24 hours of water storage, unlike CS, KA, and VE. The results of this study indicate that the flexural properties and simulated wear of CAD/CAM resin composites are different depending on the material. In addition, the flexural properties and simulated wear of CAD/CAM resin composites are influenced by thermal cycling.

  15. Wear simulation of apex seal in rotary engine under mixed lubrication

    NASA Astrophysics Data System (ADS)

    Jiang, Hanying; Zuo, Zhengxing; Liu, Jinxiang

    2018-05-01

    In this work, the wear of apex seal's running face under mixed lubrication is studied. Numerical simulation is carried out by employing the couple model of Reynolds equation, Greenwood and Tripp model and Archard's wear law. The simulation is performed both for one circle and multi circle. In the multi circle simulation, the change of contact position due to wear is considered. A method that is able to find the new contact position based on the updated apex seal's contour profile is proposed, validated and used. The result of multi circle simulation indicates that contact position changes obviously around the maximum swing angles both on leading and trailing sides with the increase number of circles. The wear depth distribution becomes more uniform with the increase of operation circle number.

  16. Computational Wear Simulation of Patellofemoral Articular Cartilage during In Vitro Testing

    PubMed Central

    Li, Lingmin; Patil, Shantanu; Steklov, Nick; Bae, Won; Temple-Wong, Michele; D'Lima, Darryl D.; Sah, Robert L.; Fregly, Benjamin J.

    2011-01-01

    Though changes in normal joint motions and loads (e.g., following anterior cruciate ligament injury) contribute to the development of knee osteoarthritis, the precise mechanism by which these changes induce osteoarthritis remains unknown. As a first step toward identifying this mechanism, this study evaluates computational wear simulations of a patellofemoral joint specimen wear tested on a knee simulator machine. A multi-body dynamic model of the specimen mounted in the simulator machine was constructed in commercial computer-aided engineering software. A custom elastic foundation contact model was used to calculate contact pressures and wear on the femoral and patellar articular surfaces using geometry created from laser scan and MR data. Two different wear simulation approaches were investigated – one that wore the surface geometries gradually over a sequence of 10 one-cycle dynamic simulations (termed the “progressive” approach), and one that wore the surface geometries abruptly using results from a single one-cycle dynamic simulation (termed the “non-progressive” approach). The progressive approach with laser scan geometry reproduced the experimentally measured wear depths and areas for both the femur and patella. The less costly non-progressive approach predicted deeper wear depths, especially on the patella, but had little influence on predicted wear areas. Use of MR data for creating the articular and subchondral bone geometry altered wear depth and area predictions by at most 13%. These results suggest that MR-derived geometry may be sufficient for simulating articular cartilage wear in vivo and that a progressive simulation approach may be needed for the patella and tibia since both remain in continuous contact with the femur. PMID:21453922

  17. Computational wear simulation of patellofemoral articular cartilage during in vitro testing.

    PubMed

    Li, Lingmin; Patil, Shantanu; Steklov, Nick; Bae, Won; Temple-Wong, Michele; D'Lima, Darryl D; Sah, Robert L; Fregly, Benjamin J

    2011-05-17

    Though changes in normal joint motions and loads (e.g., following anterior cruciate ligament injury) contribute to the development of knee osteoarthritis, the precise mechanism by which these changes induce osteoarthritis remains unknown. As a first step toward identifying this mechanism, this study evaluates computational wear simulations of a patellofemoral joint specimen wear tested on a knee simulator machine. A multibody dynamic model of the specimen mounted in the simulator machine was constructed in commercial computer-aided engineering software. A custom elastic foundation contact model was used to calculate contact pressures and wear on the femoral and patellar articular surfaces using geometry created from laser scan and MR data. Two different wear simulation approaches were investigated--one that wore the surface geometries gradually over a sequence of 10 one-cycle dynamic simulations (termed the "progressive" approach), and one that wore the surface geometries abruptly using results from a single one-cycle dynamic simulation (termed the "non-progressive" approach). The progressive approach with laser scan geometry reproduced the experimentally measured wear depths and areas for both the femur and patella. The less costly non-progressive approach predicted deeper wear depths, especially on the patella, but had little influence on predicted wear areas. Use of MR data for creating the articular and subchondral bone geometry altered wear depth and area predictions by at most 13%. These results suggest that MR-derived geometry may be sufficient for simulating articular cartilage wear in vivo and that a progressive simulation approach may be needed for the patella and tibia since both remain in continuous contact with the femur. Copyright © 2011 Elsevier Ltd. All rights reserved.

  18. How to qualify and validate wear simulation devices and methods.

    PubMed

    Heintze, S D

    2006-08-01

    The clinical significance of increased wear can mainly be attributed to impaired aesthetic appearance and/or functional restrictions. Little is known about the systemic effects of swallowed or inhaled worn particles that derive from restorations. As wear measurements in vivo are complicated and time-consuming, wear simulation devices and methods had been developed without, however, systematically looking at the factors that influence important wear parameters. Wear simulation devices shall simulate processes that occur in the oral cavity during mastication, namely force, force profile, contact time, sliding movement, clearance of worn material, etc. Different devices that use different force actuator principles are available. Those with the highest citation frequency in the literature are - in descending order - the Alabama, ACTA, OHSU, Zurich and MTS wear simulators. When following the FDA guidelines on good laboratory practice (GLP) only the expensive MTS wear simulator is a qualified machine to test wear in vitro; the force exerted by the hydraulic actuator is controlled and regulated during all movements of the stylus. All the other simulators lack control and regulation of force development during dynamic loading of the flat specimens. This may be an explanation for the high coefficient of variation of the results in some wear simulators (28-40%) and the poor reproducibility of wear results if dental databases are searched for wear results of specific dental materials (difference of 22-72% for the same material). As most of the machines are not qualifiable, wear methods applying the machine may have a sound concept but cannot be validated. Only with the MTS method have wear parameters and influencing factors been documented and verified. A good compromise with regard to costs, practicability and robustness is the Willytec chewing simulator, which uses weights as force actuator and step motors for vertical and lateral movements. The Ivoclar wear method run on the Willytec machine shows a mean coefficient of variation in vertical wear of 12%. Force measurements have revealed that in the beginning of the stylus/specimen contact phase the force impulse is 3-4 times higher during dynamic loading than during static loading. When correlating material properties to the wear results of 23 composite resins subjected to the Ivoclar method, some parameters could be identified and incorporated into a wear formula to predict wear with the Ivoclar method. A round robin test evaluating the wear of ten dental materials with five wear simulation methods showed that the results were not comparable, as all methods follow different wear testing concepts. All wear methods lack the evidence of their clinical relevance because prospective studies correlating in vitro with long-term in vivo results with identical materials are not available. For direct restorative materials, amalgam seems to be a realistic reference material. For indirect, namely crown and bridge materials, low strength ceramic is appropriate.

  19. Wear Behavior of an Unstable Knee: Stabilization via Implant Design?

    PubMed Central

    Reinders, Jörn; Kretzer, Jan Philippe

    2014-01-01

    Background. Wear-related failures and instabilities are frequent failure mechanisms of total knee replacements. High-conforming designs may provide additional stability for the joint. This study analyzes the effects of a ligamentous insufficiency on the stability and the wear behavior of a high-conforming knee design. Methods. Two simulator wear tests were performed on a high-conforming total knee replacement design. In the first, a ligamentous-stable knee replacement with a sacrificed anterior cruciate ligament was simulated. In the second, a ligamentous-unstable knee with additionally insufficient posterior cruciate ligament and medial collateral ligament was simulated. Wear was determined gravimetrically and wear particles were analyzed. Implant kinematics was recorded during simulation. Results. Significantly higher wear rates (P ≤ 0.001) were observed for the unstable knee (14.58 ± 0.56 mg/106 cycles) compared to the stable knee (7.97 ± 0.87 mg/106 cycles). A higher number of wear particles with only small differences in wear particle characteristics were observed. Under unstable knee conditions, kinematics increased significantly for translations and rotations (P ≤ 0.01). This increase was mainly attributed to higher tibial posterior translation and internal rotations. Conclusion. Higher kinematics under unstable test conditions is a result of insufficient stabilization via implant design. Due to the higher kinematics, increased wear was observed in this study. PMID:25276820

  20. Wear simulation of total knee prostheses using load and kinematics waveforms from stair climbing.

    PubMed

    Abdel-Jaber, Sami; Belvedere, Claudio; Leardini, Alberto; Affatato, Saverio

    2015-11-05

    Knee wear simulators are meant to perform load cycles on knee implants under physiological conditions, matching exactly, if possible, those experienced at the replaced joint during daily living activities. Unfortunately, only conditions of low demanding level walking, specified in ISO-14243, are used conventionally during such tests. A recent study has provided a consistent knee kinematic and load data-set measured during stair climbing in patients implanted with a specific modern total knee prosthesis design. In the present study, wear simulation tests were performed for the first time using this data-set on the same prosthesis design. It was hypothesised that more demanding tasks would result in wear rates that differ from those observed in retrievals. Four prostheses for total knee arthroplasty were tested using a displacement-controlled knee wear simulator for two million cycles at 1.1 Hz, under kinematics and load conditions typical of stair climbing. After simulation, the corresponding damage scars on the bearings were qualified and compared with equivalent explanted prostheses. An average mass loss of 20.2±1.5 mg was found. Scanning digital microscopy revealed similar features, though the explant had a greater variety of damage modes, including a high prevalence of adhesive wear damage and burnishing in the overall articulating surface. This study confirmed that the results from wear simulation machines are strongly affected by kinematics and loads applied during simulations. Based on the present results for the full understanding of the current clinical failure of knee implants, a more comprehensive series of conditions are necessary for equivalent simulations in vitro. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Simulated studies of wear and friction in total hip prosthesis components with various ball sizes and surface finishes

    NASA Technical Reports Server (NTRS)

    Swikert, M. A.; Johnson, R. L.

    1976-01-01

    Experiments were conducted on a newly designed total hip joint simulator. The apparatus closely simulates the complex motions and loads of the human hip in normal walking. The wear and friction of presently used appliance configurations and materials were determined. A surface treatment of the metal femoral ball specimens was applied to influence wear. The results of the investigation indicate that wear can be reduced by mechanical treatment of metal femoral ball surfaces. A metallographic examination and surface roughness measurements were made.

  2. 3D Simulation Modeling of the Tooth Wear Process.

    PubMed

    Dai, Ning; Hu, Jian; Liu, Hao

    2015-01-01

    Severe tooth wear is the most common non-caries dental disease, and it can seriously affect oral health. Studying the tooth wear process is time-consuming and difficult, and technological tools are frequently lacking. This paper presents a novel method of digital simulation modeling that represents a new way to study tooth wear. First, a feature extraction algorithm is used to obtain anatomical feature points of the tooth without attrition. Second, after the alignment of non-attrition areas, the initial homogeneous surface is generated by means of the RBF (Radial Basic Function) implicit surface and then deformed to the final homogeneous by the contraction and bounding algorithm. Finally, the method of bilinear interpolation based on Laplacian coordinates between tooth with attrition and without attrition is used to inversely reconstruct the sequence of changes of the 3D tooth morphology during gradual tooth wear process. This method can also be used to generate a process simulation of nonlinear tooth wear by means of fitting an attrition curve to the statistical data of attrition index in a certain region. The effectiveness and efficiency of the attrition simulation algorithm are verified through experimental simulation.

  3. 3D Simulation Modeling of the Tooth Wear Process

    PubMed Central

    Dai, Ning; Hu, Jian; Liu, Hao

    2015-01-01

    Severe tooth wear is the most common non-caries dental disease, and it can seriously affect oral health. Studying the tooth wear process is time-consuming and difficult, and technological tools are frequently lacking. This paper presents a novel method of digital simulation modeling that represents a new way to study tooth wear. First, a feature extraction algorithm is used to obtain anatomical feature points of the tooth without attrition. Second, after the alignment of non-attrition areas, the initial homogeneous surface is generated by means of the RBF (Radial Basic Function) implicit surface and then deformed to the final homogeneous by the contraction and bounding algorithm. Finally, the method of bilinear interpolation based on Laplacian coordinates between tooth with attrition and without attrition is used to inversely reconstruct the sequence of changes of the 3D tooth morphology during gradual tooth wear process. This method can also be used to generate a process simulation of nonlinear tooth wear by means of fitting an attrition curve to the statistical data of attrition index in a certain region. The effectiveness and efficiency of the attrition simulation algorithm are verified through experimental simulation. PMID:26241942

  4. Type of motion and lubricant in wear simulation of polyethylene acetabular cup.

    PubMed

    Saikko, V; Ahlroos, T

    1999-01-01

    The wear of ultra-high molecular weight polyethylene, the most commonly used bearing material in prosthetic joints, is often substantial, posing a significant clinical problem. For a long time, there has been a need for simple but still realistic wear test devices for prosthetic joint materials. The wear factors produced by earlier reciprocating and unidirectionally rotating wear test devices for polyethylene are typically two orders of magnitude too low, both in water and in serum lubrication. Wear is negligible even under multidirectional motion in water. A twelve-station, circularly translating pin-on-disc (CTPOD) device and a modification of the established biaxial rocking motion hip joint simulator were built. With these simple and inexpensive devices, and with the established three-axis hip joint simulator, realistic wear simulation was achieved. This was due to serum lubrication and to the fact that the direction of sliding constantly changed relative to the polyethylene specimen. The type and magnitude of load was found to be less important. The CTPOD tests showed that the subsurface brittle region, which results from gamma irradiation sterilization of polyethylene in air, has poor wear resistance. Phospholipid and soy protein lubrication resulted in unrealistic wear. The introduction of devices like CTPOD may boost wear studies, rendering them feasible without heavy investment.

  5. Improved single- and multi-contact life-time testing of dental restorative materials using key characteristics of the human masticatory system and a force/position-controlled robotic dental wear simulator.

    PubMed

    Raabe, D; Harrison, A; Ireland, A; Alemzadeh, K; Sandy, J; Dogramadzi, S; Melhuish, C; Burgess, S

    2012-03-01

    This paper presents a new in vitro wear simulator based on spatial parallel kinematics and a biologically inspired implicit force/position hybrid controller to replicate chewing movements and dental wear formations on dental components, such as crowns, bridges or a full set of teeth. The human mandible, guided by passive structures such as posterior teeth and the two temporomandibular joints, moves with up to 6 degrees of freedom (DOF) in Cartesian space. The currently available wear simulators lack the ability to perform these chewing movements. In many cases, their lack of sufficient DOF enables them only to replicate the sliding motion of a single occlusal contact point by neglecting rotational movements and the motion along one Cartesian axis. The motion and forces of more than one occlusal contact points cannot accurately be replicated by these instruments. Furthermore, the majority of wear simulators are unable to control simultaneously the main wear-affecting parameters, considering abrasive mechanical wear, which are the occlusal sliding motion and bite forces in the constraint contact phase of the human chewing cycle. It has been shown that such discrepancies between the true in vivo and the simulated in vitro condition influence the outcome and the quality of wear studies. This can be improved by implementing biological features of the human masticatory system such as tooth compliance realized through the passive action of the periodontal ligament and active bite force control realized though the central nervous system using feedback from periodontal preceptors. The simulator described in this paper can be used for single- and multi-occlusal contact testing due to its kinematics and ability to exactly replicate human translational and rotational mandibular movements with up to 6 DOF without neglecting movements along or around the three Cartesian axes. Recorded human mandibular motion and occlusal force data are the reference inputs of the simulator. Experimental studies of wear using this simulator demonstrate that integrating the biological feature of combined force/position hybrid control in dental material testing improves the linearity and reduces the variability of results. In addition, it has been shown that present biaxially operated dental wear simulators are likely to provide misleading results in comparative in vitro/in vivo one-contact studies due to neglecting the occlusal sliding motion in one plane which could introduce an error of up to 49% since occlusal sliding motion D and volumetric wear loss V(loss) are proportional.

  6. Preferential superior surface motion in wear simulations of the Charité total disc replacement.

    PubMed

    Goreham-Voss, Curtis M; Vicars, Rachel; Hall, Richard M; Brown, Thomas D

    2012-06-01

    Laboratory wear simulations of the dual-bearing surface Charité total disc replacement (TDR) are complicated by the non-specificity of the device's center of rotation (CoR). Previous studies have suggested that articulation of the Charité preferentially occurs at the superior-bearing surface, although it is not clear how sensitive this phenomenon is to lubrication conditions or CoR location. In this study, a computational wear model is used to study the articulation kinematics and wear of the Charité TDR. Implant wear was found to be insensitive to the CoR location, although seemingly non-physiologic endplate motion can result. Articulation and wear were biased significantly to the superior-bearing surface, even in the presence of significant perturbations of loading and friction. The computational wear model provides novel insight into the mechanics and wear of the Charité TDR, allowing for better interpretation of in vivo results, and giving useful insight for designing future laboratory physical tests.

  7. Study on biocompatibility, tribological property and wear debris characterization of ultra-low-wear polyethylene as artificial joint materials.

    PubMed

    Bian, Yan-Yan; Zhou, Lei; Zhou, Gang; Jin, Zhong-Min; Xin, Shi-Xuan; Hua, Zi-Kai; Weng, Xi-Sheng

    2018-06-01

    Ultra-low-wear polyethylene (ULWPE) is a new type polyethylene made by experts who are from China petrochemical research institute, which is easy to process and implant. Preliminary test showed it was more resistant to wear than that of Ultra-high-molecular weight polyethylene (UHMWPE). The purpose of the research is to study biocompatibility, bio-tribological properties and debris characterization of ULWPE. Cytotoxicity test, hemolysis test, acute/chronic toxicity and muscular implantation test were conducted according to national standard GB/T-16886/ISO-10993 for evaluation requirements of medical surgical implants. We obtained that this novel material had good biocompatibility and biological safety. The wear performance of ULWPE and UHMWPE was evaluated in a pin-on-disc (POD) wear tester within two million cycles and a knee wear simulator within six million cycles. We found that the ULWPE was higher abrasion resistance than the UHMWPE, the wear rate of ULWPE by POD test and knee wear simulator was 0.4 mg/10 6 cycles and (16.9 ± 1.8)mg/10 6 cycles respectively, while that of UHMWPE was 1.8 mg/10 6 cycles and (24.6 ± 2.4)mg/10 6 cycles. The morphology of wear debris is also an important factor to evaluate artificial joint materials, this study showed that the ULWPE wear debris gotten from the simulator had various different shapes, including spherical, block, tear, etc. The morphology of worn surface and wear debris analysis showed that wear mechanisms of ULWPE were adhesion wear, abrasive wear and fatigue wear and other wear forms, which were consistent with that of UHMWPE. Thus we conclude that ULWPE is expected to be a lifetime implantation of artificial joint. Copyright © 2018 Elsevier Ltd. All rights reserved.

  8. Biotribological evaluation of artificial disc arthroplasty devices: influence of loading and kinematic patterns during in vitro wear simulation.

    PubMed

    Grupp, Thomas M; Yue, James J; Garcia, Rolando; Basson, Janet; Schwiesau, Jens; Fritz, Bernhard; Blömer, Wilhelm

    2009-01-01

    Wear simulation is an essential pre-clinical method to predict the mid- and long-term clinical wear behavior of newly introduced devices for total disc arthroplasty. The main requirement of a suitable method for spinal wear simulation has to be the ability to distinguish between design concepts and allow for a direct comparison of predicate devices. The objective of our study was to investigate the influence of loading and kinematic patterns based on two different protocols for spinal wear simulation (ISO/FDIS 18192-1 (2006) and ASTM F2423-05). In vitro wear simulation was performed with six activ L lumbar artificial disc devices (Aesculap Tuttlingen, Germany). The applied kinematic pattern of movement was multidirectional for ISO (elliptic track) and unidirectional with a curvilinear shape for ASTM. Testing was done for 10 million cycles in the ISO loading mode and afterwards with the same specimens for 5 million cycles according to the ASTM protocol with a customized six-station servohydraulic spinal wear simulator (EndoLab Thansau, Germany). Gravimetrical and geometrical wear assessment, a slide track analysis correlated to an optical surface characterization, and an estimation of particle size and morphology were performed. The gravimetric wear rate for the first 10 million cycles was ISO(initial) = 2.7 +/- 0.3 mg/million cycles. During the ASTM test period (10-15 million cycles) a gravimetric wear rate of 0.14 +/- 0.06 mg/million cycles was estimated. The wear rates between the ISO and ASTM driven simulations differ substantially (approximately 20-fold) and statistical analysis demonstrates a significant difference (p < 0.001) between the test groups. The main explanation of divergency between ISO and ASTM driven wear simulations is the multidirectional pattern of movement described in the ISO document resulting in a cross-shear stress on the polyethylene material. Due to previous retrieval observations, it seems to be very unlikely that a lumbar artificial disc is loaded with a linear wear path.Testing according to ASTM F2423-05 with pure unidirectional motion does not reflect the kinematics of TDA patients' daily activities. Based on our findings it seems to be more reliable to predict the clinical wear behavior of an artificial disc replacement using the ISO/FDIS 18192-1 method.

  9. Biotribological evaluation of artificial disc arthroplasty devices: influence of loading and kinematic patterns during in vitro wear simulation

    PubMed Central

    Yue, James J.; Garcia, Rolando; Basson, Janet; Schwiesau, Jens; Fritz, Bernhard; Blömer, Wilhelm

    2008-01-01

    Wear simulation is an essential pre-clinical method to predict the mid- and long-term clinical wear behavior of newly introduced devices for total disc arthroplasty. The main requirement of a suitable method for spinal wear simulation has to be the ability to distinguish between design concepts and allow for a direct comparison of predicate devices. The objective of our study was to investigate the influence of loading and kinematic patterns based on two different protocols for spinal wear simulation (ISO/FDIS 18192-1 (2006) and ASTM F2423-05). In vitro wear simulation was performed with six activ® L lumbar artificial disc devices (Aesculap Tuttlingen, Germany). The applied kinematic pattern of movement was multidirectional for ISO (elliptic track) and unidirectional with a curvilinear shape for ASTM. Testing was done for 10 million cycles in the ISO loading mode and afterwards with the same specimens for 5 million cycles according to the ASTM protocol with a customized six-station servohydraulic spinal wear simulator (EndoLab Thansau, Germany). Gravimetrical and geometrical wear assessment, a slide track analysis correlated to an optical surface characterization, and an estimation of particle size and morphology were performed. The gravimetric wear rate for the first 10 million cycles was ISOinitial = 2.7 ± 0.3 mg/million cycles. During the ASTM test period (10–15 million cycles) a gravimetric wear rate of 0.14 ± 0.06 mg/million cycles was estimated. The wear rates between the ISO and ASTM driven simulations differ substantially (approximately 20-fold) and statistical analysis demonstrates a significant difference (p < 0.001) between the test groups. The main explanation of divergency between ISO and ASTM driven wear simulations is the multidirectional pattern of movement described in the ISO document resulting in a cross-shear stress on the polyethylene material. Due to previous retrieval observations, it seems to be very unlikely that a lumbar artificial disc is loaded with a linear wear path.Testing according to ASTM F2423-05 with pure unidirectional motion does not reflect the kinematics of TDA patients‘ daily activities. Based on our findings it seems to be more reliable to predict the clinical wear behavior of an artificial disc replacement using the ISO/FDIS 18192-1 method. PMID:19050942

  10. Wear Characteristics and Volume Loss of CAD/CAM Ceramic Materials.

    PubMed

    Zurek, Alec D; Alfaro, Maria F; Wee, Alvin G; Yuan, Judy Chia-Chun; Barao, Valentim A; Mathew, Mathew T; Sukotjo, Cortino

    2018-03-06

    In the field of prosthodontics, patients often require complex and extensive restorative care. This can involve the use of dental restorations to restore teeth on both the maxillary and mandibular arch. Current literature has evaluated the wear properties of different dental ceramics against enamel, but studies regarding dental ceramics opposing one another are limited. The purpose of this study was to assess the wear potential and wear behavior of CAD/CAM zirconia (ZR) and lithium disilicate (LD) materials against a similar ceramic material, and how the surface finish of these dental ceramics might affect patterns of wear. Using a sphere-on-plate tribometer system, different surface finishes (glazed-G and glazed then polished-GP) of ZR and LD were evaluated following wear simulation. Artificial saliva of physiologic pH was used as a lubricant during wear simulation at 37°C. The coefficient of friction (COF) was calculated during the wear simulation. After wear simulation was complete, volume loss, surface roughness, and surface characterization of the specimens were analyzed using white-light interferometry and scanning electron microscopy (SEM). Statistical significance between materials and surface finish was established with two-way ANOVA and Bonferroni post hoc test (α = 0.05). Based on the 2-way ANOVA, material (p = 0.002) significantly affected the COF. LD showed a higher COF (p = 0.002) than ZR. Material (p < 0.001) and surface finish (p = 0.004) significantly affected the surface roughness inside the scar. ZR had significantly lower surface roughness compared to LD (p < 0.001). For outside scar, surface finish (p < 0.001) significantly affected the surface roughness. Polished specimens showed significantly higher roughness compared to glazed specimens for both inside (p = 0.004) and outside scar (p < 0.001). For volume loss, material (p < 0.001) and the interaction between material and surface finish (p < 0.001) were statistically significant. LD had higher volume loss than ZR (p < 0.001). For both glazed and polished finished, LD-G and LD-GP had significantly higher volume loss than ZR-G (p = 0.028), and ZR-GP (p < 0.001), respectively. SEM analysis indicated particle build-up and a grooving mechanism of wear for the LD-GP specimens. This suggested a three-body wear phenomenon occurring for LD-GP specimens, which was not visible in SEM imaging for other specimen types. This study demonstrated the resistance to wear and low abrasiveness of ZR when compared to LD in a simulated masticatory environment. This can be best explained by the increased strength of ZR, and the introduction of three-body wear to LD specimens from the accumulation of embedded wear debris onto its surface. Wear data and comparison of SEM images following wear simulation confirmed this interpretation. © 2018 by the American College of Prosthodontists.

  11. Mechanical modelling of tooth wear

    PubMed Central

    Kallonen, Aki

    2016-01-01

    Different diets wear teeth in different ways and generate distinguishable wear and microwear patterns that have long been the basis of palaeodiet reconstructions. Little experimental research has been performed to study them together. Here, we show that an artificial mechanical masticator, a chewing machine, occluding real horse teeth in continuous simulated chewing (of 100 000 chewing cycles) is capable of replicating microscopic wear features and gross wear on teeth that resemble wear in specimens collected from nature. Simulating pure attrition (chewing without food) and four plant material diets of different abrasives content (at n = 5 tooth pairs per group), we detected differences in microscopic wear features by stereomicroscopy of the chewing surface in the number and quality of pits and scratches that were not always as expected. Using computed tomography scanning in one tooth per diet, absolute wear was quantified as the mean height change after the simulated chewing. Absolute wear increased with diet abrasiveness, originating from phytoliths and grit. In combination, our findings highlight that differences in actual dental tissue loss can occur at similar microwear patterns, cautioning against a direct transformation of microwear results into predictions about diet or tooth wear rate. PMID:27411727

  12. A hip joint simulator study using simplified loading and motion cycles generating physiological wear paths and rates.

    PubMed

    Barbour, P S; Stone, M H; Fisher, J

    1999-01-01

    In some designs of hip joint simulator the cost of building a highly complex machine has been offset with the requirement for a large number of test stations. The application of the wear results generated by these machines depends on their ability to reproduce physiological wear rates and processes. In this study a hip joint simulator has been shown to reproduce physiological wear using only one load vector and two degrees of motion with simplified input cycles. The actual path of points on the femoral head relative to the acetabular cup were calculated and compared for physiological and simplified input cycles. The in vitro wear rates were found to be highly dependent on the shape of these paths and similarities could be drawn between the shape of the physiological paths and the simplified elliptical paths.

  13. Simulation of wear in overhead current collection systems

    NASA Astrophysics Data System (ADS)

    Klapas, D.; Benson, F. A.; Hackam, R.

    1985-09-01

    Apparatus have been designed to simulate the wear from conductors in a railway current collection system. The main features of the wear machine include a continuous monitoring of the strip wear, strip traversing, and dwell-time test facilities for the investigation of oxidational wear on a copper disk, simulating the contact wire. Disk wear is measured in situ by the spherical indentations method. Typical results of the specific wear rate are also presented to demonstrate the capability of the apparatus.

  14. Tribological Properties of Ti-Based Alloys in a Simulated Bone-Implant Interface with Ringer's Solution at Fretting Contacts

    PubMed Central

    Ramos-Saenz, C.R.; Sundaram, P.A.; Diffoot-Carlo, N.

    2010-01-01

    The wear properties of oxidized and non-oxidized gamma-TiAl (a potential biomaterial) as well as Ti-6Al-4V and CP-Ti disks were studied and characterized by means of standard wear tests using a custom made bone pin arrangement. The Ti-base disks were oxidized in air at 500°C and 800°C for one hour. The tribological properties of the oxides formed over the disks were studied using a linear reciprocating wear testing machine under both dry and simulated biological conditions using Ringer's solution. Loss of metal oxide and coefficient of friction values were determined from the wear testing. From the results, abrasion and adhesion were the primary wear mechanisms in each of the three alloy-bone pairs. Specifically, the oxide formed on gamma-TiAl possessed the highest COF and wear resistance of the three materials which were studied. Also, as expected, bone wears down faster than the Ti-base metal oxide. PMID:20826360

  15. Degradation of experimental composite materials and in vitro wear simulation

    NASA Astrophysics Data System (ADS)

    Givan, Daniel Allen

    2001-12-01

    The material, mechanical, and clinical aspects of surface degradation of resin composite dental restorative materials by in vitro wear simulation continues to be an area of active research. To investigate wear mechanisms, a series of experimental resin composites with variable and controlled filler particle shape and loading were studied by in vitro wear simulation. The current investigation utilized a simulation that isolated the wear environment, entrapped high and low modulus debris, and evaluated the process including machine and fluid flow dynamics. The degradation was significantly affected by filler particle shape and less by particle loading. The spherical particle composites demonstrated wear loss profiles suggesting an optimized filler loading may exist. This was also demonstrated by the trends in the mechanical properties. Very little difference in magnitude was noted for the wear of irregular particle composites as a function of particulate size; and as a group they were more wear resistant than spherical particle composites. This was the result of different mechanisms of wear that were correlated with the three-dimensional particle shape. The abrasive effects of the aggregate particles and the polymeric stabilization of the irregular shape versus the destabilization and "plucking" of the spherical particles resulted in an unprotected matrix that accounted for significantly greater wear of spherical composite. A model and analysis was developed to explain the events associated with the progressive material wear loss. The initial phase was explained by fatigue-assisted microcracking and loss of material segments in a zone of high stress immediately beneath a point of high stress contact. The early phase was characterized by the development of a small facet primarily by fatigue-assisted microcracking. Although the translation effects were minimal, some three-body and initial two-body wear events were also present. In the late phases, the abrasive effects of the debris aggregate predominated the wear process. The non-linear rate of wear loss was accelerated as the facet deepened. Physical effects, such as thermal fatigue, and chemical effects were less important but contributed to the degradation process. This study provides new insight into the role(s) of high modulus third body debris in the wear of dental composites.

  16. Study on the Effect of Diamond Grain Size on Wear of Polycrystalline Diamond Compact Cutter

    NASA Astrophysics Data System (ADS)

    Abdul-Rani, A. M.; Che Sidid, Adib Akmal Bin; Adzis, Azri Hamim Ab

    2018-03-01

    Drilling operation is one of the most crucial step in oil and gas industry as it proves the availability of oil and gas under the ground. Polycrystalline Diamond Compact (PDC) bit is a type of bit which is gaining popularity due to its high Rate of Penetration (ROP). However, PDC bit can easily wear off especially when drilling hard rock. The purpose of this study is to identify the relationship between the grain sizes of the diamond and wear rate of the PDC cutter using simulation-based study with FEA software (ABAQUS). The wear rates of a PDC cutter with a different diamond grain sizes were calculated from simulated cuttings of cutters against granite. The result of this study shows that the smaller the diamond grain size, the higher the wear resistivity of PDC cutter.

  17. The influence of kinematic conditions and design on the wear of patella-femoral replacements

    PubMed Central

    Maiti, Raman; Fisher, John; Rowley, Liam

    2014-01-01

    The success rate of patella-femoral arthroplasty varies between 44% and 90% in 17 years of follow-up. Several studies have been performed previously for assessing the surface wear in the patella-femoral joint. However, they have not included all six degrees of freedom. The aim of this study was to develop a six-axis patella-femoral joint simulator to assess the wear rate for two patellae designs (round and oval dome) at different kinematic conditions. An increase in patellar rotation from 1° to 4° led to a significantly (p<0.049) increased wear rate of round dome from 8.6 mm3/million cycles to 12.3 mm3/million cycles. The wear rate for oval dome increased from 6.3 mm3/million cycles to 14.5 mm3/million cycles. However, the increase was nonsignificant (p>0.08). The increase in wear rate was likely due to the higher cross shear. A decrease in patellar medial lateral displacement from passive to constrained resulted in a nonsignificant reduction in wear (p>0.06). There was no significant difference in wear rate between the two patellae designs (p>0.28). The volumetric wear under all conditions was positively correlated with the level of passive patellar tilt (rho>0.8). This is the first report of preclinical wear simulation of patella-femoral joint in a six-axis simulator under different kinematic conditions. PMID:24477888

  18. Localized and generalized simulated wear of resin composites.

    PubMed

    Barkmeier, W W; Takamizawa, T; Erickson, R L; Tsujimoto, A; Latta, M; Miyazaki, M

    2015-01-01

    A laboratory study was conducted to examine the wear of resin composite materials using both a localized and generalized wear simulation model. Twenty specimens each of seven resin composites (Esthet•X HD [HD], Filtek Supreme Ultra [SU], Herculite Ultra [HU], SonicFill [SF], Tetric EvoCeram Bulk Fill [TB], Venus Diamond [VD], and Z100 Restorative [Z]) were subjected to a wear challenge of 400,000 cycles for both localized and generalized wear in a Leinfelder-Suzuki wear simulator (Alabama machine). The materials were placed in custom cylinder-shaped stainless steel fixtures. A stainless steel ball bearing (r=2.387 mm) was used as the antagonist for localized wear, and a stainless steel, cylindrical antagonist with a flat tip was used for generalized wear. A water slurry of polymethylmethacrylate (PMMA) beads was used as the abrasive media. A noncontact profilometer (Proscan 2100) with Proscan software was used to digitize the surface contours of the pretest and posttest specimens. AnSur 3D software was used for wear assessment. For localized testing, maximum facet depth (μm) and volume loss (mm(3)) were used to compare the materials. The mean depth of the facet surface (μm) and volume loss (mm(3)) were used for comparison of the generalized wear specimens. A one-way analysis of variance (ANOVA) and Tukey post hoc test were used for data analysis of volume loss for both localized and generalized wear, maximum facet depth for localized wear, and mean depth of the facet for generalized wear. The results for localized wear simulation were as follows [mean (standard deviation)]: maximum facet depth (μm)--Z, 59.5 (14.7); HU, 99.3 (16.3); SU, 102.8 (13.8); HD, 110.2 (13.3); VD, 114.0 (10.3); TB, 125.5 (12.1); SF, 195.9 (16.9); volume loss (mm(3))--Z, 0.013 (0.002); SU, 0.026 (0.006); HU, 0.043 (0.008); VD, 0.057 (0.009); HD, 0.058 (0.014); TB, 0.061 (0.010); SF, 0.135 (0.024). Generalized wear simulation results were as follows: mean depth of facet (μm)--Z, 9.3 (3.4); SU, 12.8 (3.1); HU, 15.6 (3.2); TB, 19.2 (4.8); HD, 26.8 (6.5); VD, 29.1 (5.5); SF, 35.6 (8.4); volume loss (mm(3))--Z, 0.132 (0.049); SU, 0.0179 (0.042); HU, 0.224 (0.044); TB, 0.274 (0.065); HD, 0.386 (0.101); VD, 0.417 (0.076); SF, 0.505 (0.105). The ANOVA showed a significant difference among materials (p<0.001) for facet depth and volume loss for both localized and generalized wear. The post hoc test revealed differences (p<0.05) in localized and generalized wear values among the seven resin composites examined in this study. The findings provide valuable information regarding the relative wear characteristics of the materials in this study.

  19. Analysis of the kinematics of different hip simulators used to study wear of candidate materials for the articulation of total hip arthroplasties.

    PubMed

    Ramamurti, B S; Estok, D M; Jasty, M; Harris, W H

    1998-05-01

    We developed an analytical technique to determine the paths traced by specific points on the femoral head against the acetabulum in the human hip joint during gait. The purpose of the study was to apply this technique to the mechanical hip simulators chosen to conduct wear tests on polymeric acetabular liners used in total hip replacements. These simulators differ from one another in the type of motion produced, apart from other variables such as type of lubricant and head position. Due to the variation in the kinematics between the machines, the paths traced by the points on the femoral head against the acetabular liner ranged from simple linear traces to figure-8 loops and quasi-elliptical paths during a single simulator cycle. The distances traveled by these points during the same period also varied appreciably among the different hip simulator designs. These results are important when combined with other studies that have shown that kinematics can play an important role in the outcome of in vitro wear experiments. The kinematic differences quantified in this study can partially explain the substantial differences in wear data reported from different simulator designs and also underscore the usefulness of the technique described in this study in judging the results from different hip simulator experiments.

  20. Potential countersample materials for in vitro simulation wear testing.

    PubMed

    Shortall, Adrian C; Hu, Xiao Q; Marquis, Peter M

    2002-05-01

    Any laboratory investigation of the wear resistance of dental materials needs to consider oral conditions so that in vitro wear results can be correlated with in vivo findings. The choice of the countersample is a critical factor in establishing the pattern of tribological wear and in achieving an efficient in vitro wear testing system. This research investigated the wear behavior and surface characteristics associated with three candidate countersample materials used for in vitro wear testing in order to identify a possible suitable substitute for human dental enamel. Three candidate materials, stainless steel, steatite and dental porcelain were evaluated and compared to human enamel. A variety of factors including hardness, wear surface evolution and frictional coefficients were considered, relative to the tribology of the in vivo situation. The results suggested that the dental porcelain investigated bore the closest similarity to human enamel of the materials investigated. Assessment of potential countersample materials should be based on the essential tribological simulation supported by investigations of mechanical, chemical and structural properties. The selected dental porcelain had the best simulating ability among the three selected countersample materials and this class of material may be considered as a possible countersample material for in vitro wear test purposes. Further studies are required, employing a wider range of dental ceramics, in order to optimise the choice of countersample material for standardized in vitro wear testing.

  1. Performance of Plasma Sprayed Al2O3 Coating in Bio-Simulated Environment

    NASA Astrophysics Data System (ADS)

    Yıldız, F.; Yetim, A. F.; Alsaran, A.; Çelik, A.

    2014-01-01

    Alumina coatings deposited on the surface of stainless steel 316L by the method of plasma spraying are studied. Tests for wear and corrosion are preformed in Ringer's solution simulating a human body environment. The structure, microhardness, wear resistance and corrosion resistance of the steel are determined with and without a coating. Deposition of a coating onto the stainless steel is shown to be an effective means for protecting implants from corrosion and wear.

  2. Estimation of wear in total hip replacement using a ten station hip simulator.

    PubMed

    Brummitt, K; Hardaker, C S

    1996-01-01

    The results of hip simulator tests on a total of 16 total hip joints, all of them 22.25 mm Charnley designs, are presented. Wear at up to 6.75 million cycles was assessed by using a coordinate measuring machine. The results gave good agreement with clinical estimates of wear rate on the same design of joint replacement from a number of sources. Good agreement was also obtained when comparison was made with the published results from more sophisticated simulators. The major source of variation in the results was found to occur in the first million cycles where creep predominates. The results of this study support the use of this type of simplified simulator for estimating wear in a total hip prosthesis. The capability to test a significant number of joints simultaneously may make this mechanism preferable to more complex machines in many cases.

  3. Wear resistance of four types of vacuum-formed retainer materials: a laboratory study.

    PubMed

    Raja, Taiyub A; Littlewood, Simon J; Munyombwe, Theresa; Bubb, Nigel L

    2014-07-01

    To investigate the resistance to wear of four different vacuum-formed retainer (VFR) materials: Essix C+, Essix ACE, Duran, and Tru-Tain. Essix C+ is a polypropylene polymer; the other materials are polyethylene co-polymers. The study was undertaken at the Leeds Dental Institute, Leeds, UK, with 26 samples in each group. The specimens were vacuum-formed according to the manufacturers' guidelines, and a custom-made wear-simulation machine was used to conduct the test. Each specimen was subjected to 1000 cycles of the wear simulation, with steatite balls as the antagonist material. The resistance to wear of the VFR materials was evaluated by measuring the maximum wear depth using noncontact, three-dimensional surface profilometry. The wear depth was given in micrometers. The median wear depth was 63.20 µm for the Essix C+ group, 7.88 µm for the Essix ACE group, 9.75 µm for the Duran group, and 12.08 µm for the Tru-Tain group. The Kruskal-Wallis test to compare the four VFR materials detected a statistically significant difference between the groups (P < .001). Comparisons of the groups using the Mann-Whitney U-test demonstrated that the Essix C+ group had significantly greater wear than the other three groups (P < .001). There was no statistically significant difference in median wear depth between the two groups with the least amount of wear-the Essix ACE and Duran groups. Under the standardized conditions of this laboratory study, the three polyethylene co-polymer materials-Essix ACE, Duran, and Tru-Tain-exhibited significantly less wear than the polypropylene material, Essix C+.

  4. Micro X-Ray Computed Tomography Mass Loss Assessment of Different UHMWPE: A Hip Joint Simulator Study on Standard vs. Cross-Linked Polyethylene

    PubMed Central

    Zanini, Filippo; Carmignato, Simone

    2017-01-01

    More than 60.000 hip arthroplasty are performed every year in Italy. Although Ultra-High-Molecular-Weight-Polyethylene remains the most used material as acetabular cup, wear of this material induces over time in vivo a foreign-body response and consequently osteolysis, pain, and the need of implant revision. Furthermore, oxidative wear of the polyethylene provoke several and severe failures. To solve these problems, highly cross-linked polyethylene and Vitamin-E-stabilized polyethylene were introduced in the last years. In in vitro experiments, various efforts have been made to compare the wear behavior of standard PE and vitamin-E infused liners. In this study we compared the in vitro wear behavior of two different configurations of cross-linked polyethylene (with and without the add of Vitamin E) vs. the standard polyethylene acetabular cups. The aim of the present study was to validate a micro X-ray computed tomography technique to assess the wear of different commercially available, polyethylene’s acetabular cups after wear simulation; in particular, the gravimetric method was used to provide reference wear values. The agreement between the two methods is documented in this paper. PMID:28107468

  5. Studies of worn surfaces by relocation profilometry

    NASA Astrophysics Data System (ADS)

    Rîpă, M.; Iliuță, V.

    2018-01-01

    By relocation profilometry, a series of surface profiles can be recorded from the same track on a specimen. These techniques are used for monitoring specific particular points on the surface subjected to wear processes, in a more accurate manner as comparing to those involving average statistical information for surface. The method is providing a much more significant information about the surface, in a more efficient way, assuring that the same unworn investigated surface is studied after wear test. The studied roughness digital profiles were obtained before and after the testing of rolling/sliding line contacts, characteristic for spur gears, which has been simulated on SAE sets, with a two rollers test machine. The acquisition of the relocated profiles is performed on the same generatrix of the roller, before and after wear testing. To correlate the unworn and worn profiles, a spheroconical indentation was created on the circumferential surface of the disk, in the zone of the tested roller that remain unworn during the test. Measuring changes of the profiles by relocation techniques, two methods for wear assessment are presented: linear wear estimation by simulating the profile wearing and estimation of the volume wear.

  6. Wear Scar Similarities between Retrieved and Simulator-Tested Polyethylene TKR Components: An Artificial Neural Network Approach

    PubMed Central

    2016-01-01

    The aim of this study was to determine how representative wear scars of simulator-tested polyethylene (PE) inserts compare with retrieved PE inserts from total knee replacement (TKR). By means of a nonparametric self-organizing feature map (SOFM), wear scar images of 21 postmortem- and 54 revision-retrieved components were compared with six simulator-tested components that were tested either in displacement or in load control according to ISO protocols. The SOFM network was then trained with the wear scar images of postmortem-retrieved components since those are considered well-functioning at the time of retrieval. Based on this training process, eleven clusters were established, suggesting considerable variability among wear scars despite an uncomplicated loading history inside their hosts. The remaining components (revision-retrieved and simulator-tested) were then assigned to these established clusters. Six out of five simulator components were clustered together, suggesting that the network was able to identify similarities in loading history. However, the simulator-tested components ended up in a cluster at the fringe of the map containing only 10.8% of retrieved components. This may suggest that current ISO testing protocols were not fully representative of this TKR population, and protocols that better resemble patients' gait after TKR containing activities other than walking may be warranted. PMID:27597955

  7. Wear-screening and joint simulation studies vs. materials selection and prosthesis design.

    PubMed

    Clarke, I C

    1982-01-01

    Satisfactory friction and wear performance of orthomedic biomaterials is an essential criterion for both hemiarthroplasty and total joint replacements. This report will chart the clinical historical experience of candidate biomaterials with their wear resistance and compare/contrast these data to experimental test predictions. The latter review will encompass publications dealing with both joint simulators and the more basic friction and wear screening devices. Special consideration will be given to the adequacy of the test protocol, the design of the experimental machines, and the accuracy of the measurement techniques. The discussion will then center on clinical reality vs. experimental adequacy and summarize current developments.

  8. Switch Panel wear loading - a parametric study regarding governing train operational factors

    NASA Astrophysics Data System (ADS)

    Hiensch, E. J. M.; Burgelman, N.

    2017-09-01

    The acting forces and resulting material degradation at the running surfaces of wheels and rail are determined by vehicle, track, interface and operational characteristics. To effectively manage the experienced wear, plastic deformation and crack development at wheels and rail, the interaction between vehicle and track demands a system approach both in maintenance and in design. This requires insight into the impact of train operational parameters on rail- and wheel degradation, in particular at switches and crossings due to the complex dynamic behaviour of a railway vehicle at a turnout. A parametric study was carried out by means of vehicle-track simulations within the VAMPIRE® multibody simulation software, performing a sensitivity analysis regarding operational factors and their impact on expected switch panel wear loading. Additionally, theoretical concepts were cross-checked with operational practices by means of a case study in response to a dramatic change in lateral rail wear development at specific switches in Dutch track. Data from train operation, track maintenance and track inspection were analysed, providing further insight into the operational dependencies. From the simulations performed in this study, it was found that switch rail lateral wear loading at the diverging route of a 1:9 type turnout is significantly influenced by the level of wheel-rail friction and to a lesser extent by the direction of travel (facing or trailing). The influence of other investigated parameters, being vehicle speed, traction, gauge widening and track layout is found to be small. Findings from the case study further confirm the simulation outcome. This research clearly demonstrates the contribution flange lubrication can have in preventing abnormal lateral wear at locations where the wheel-rail interface is heavily loaded.

  9. Engineering of a multi-station shoulder simulator.

    PubMed

    Smith, Simon L; Li, Lisa; Joyce, Thomas J

    2016-05-01

    This work aimed to engineer a multi-station shoulder simulator in order to wear test shoulder prostheses using recognized shoulder activities of daily living. A bespoke simulator was designed, built and subject to commissioning trials before a first wear test was conducted. Five JRI Orthopaedics Reverse Shoulder VAIOS 42 mm prostheses were tested for 2.0 million cycles and a mean wear rate and standard deviation of 14.2 ± 2.1 mm(3)/10(6) cycles measured for the polymeric glenoid components. This result when adjusted for prostheses diameters and test conditions showed excellent agreement with results from hip simulator studies of similar materials in a lubricant of bovine serum. The Newcastle Shoulder Simulator is the first multi-station shoulder simulator capable of applying physiological motion and loading for typical activities of daily living. © IMechE 2016.

  10. In-silico wear prediction for knee replacements--methodology and corroboration.

    PubMed

    Strickland, M A; Taylor, M

    2009-07-22

    The capability to predict in-vivo wear of knee replacements is a valuable pre-clinical analysis tool for implant designers. Traditionally, time-consuming experimental tests provided the principal means of investigating wear. Today, computational models offer an alternative. However, the validity of these models has not been demonstrated across a range of designs and test conditions, and several different formulas are in contention for estimating wear rates, limiting confidence in the predictive power of these in-silico models. This study collates and retrospectively simulates a wide range of experimental wear tests using fast rigid-body computational models with extant wear prediction algorithms, to assess the performance of current in-silico wear prediction tools. The number of tests corroborated gives a broader, more general assessment of the performance of these wear-prediction tools, and provides better estimates of the wear 'constants' used in computational models. High-speed rigid-body modelling allows a range of alternative algorithms to be evaluated. Whilst most cross-shear (CS)-based models perform comparably, the 'A/A+B' wear model appears to offer the best predictive power amongst existing wear algorithms. However, the range and variability of experimental data leaves considerable uncertainty in the results. More experimental data with reduced variability and more detailed reporting of studies will be necessary to corroborate these models with greater confidence. With simulation times reduced to only a few minutes, these models are ideally suited to large-volume 'design of experiment' or probabilistic studies (which are essential if pre-clinical assessment tools are to begin addressing the degree of variation observed clinically and in explanted components).

  11. In-situ electrochemical study of interaction of tribology and corrosion in artificial hip prosthesis simulators.

    PubMed

    Yan, Yu; Dowson, Duncan; Neville, Anne

    2013-02-01

    The second generation Metal-on-Metal (MoM) hip replacements have been considered as an alternative to commonly used Polyethylene-on-Metal (PoM) joint prostheses due to polyethylene wear debris induced osteolysis. However, the role of corrosion and the biofilm formed under tribological contact are still not fully understood. Enhanced metal ion concentrations have been reported widely from hair, blood and urine samples of patients who received metal hip replacements and in isolated cases when abnormally high levels have caused adverse local tissue reactions. An understanding of the origin of metal ions is really important in order to design alloys for reduced ion release. Reciprocating pin-on-plate wear tester is a standard instrument to assess the interaction of corrosion and wear. However, more realistic hip simulator can provide a better understanding of tribocorrosion process for hip implants. It is very important to instrument the conventional hip simulator to enable electrochemical measurements. In this study, simple reciprocating pin-on-plate wear tests and hip simulator tests were compared. It was found that metal ions originated from two sources: (a) a depassivation of the contacting surfaces due to tribology (rubbing) and (b) corrosion of nano-sized wear particles generated from the contacting surfaces. Copyright © 2012 Elsevier Ltd. All rights reserved.

  12. CR TKA UHMWPE wear tested after artificial aging of the vitamin E treated gliding component by simulating daily patient activities.

    PubMed

    Schwiesau, Jens; Fritz, Bernhard; Kutzner, Ines; Bergmann, Georg; Grupp, Thomas M

    2014-01-01

    The wear behaviour of total knee arthroplasty (TKA) is dominated by two wear mechanisms: the abrasive wear and the delamination of the gliding components, where the second is strongly linked to aging processes and stress concentration in the material. The addition of vitamin E to the bulk material is a potential way to reduce the aging processes. This study evaluates the wear behaviour and delamination susceptibility of the gliding components of a vitamin E blended, ultra-high molecular weight polyethylene (UHMWPE) cruciate retaining (CR) total knee arthroplasty. Daily activities such as level walking, ascending and descending stairs, bending of the knee, and sitting and rising from a chair were simulated with a data set received from an instrumented knee prosthesis. After 5 million test cycles no structural failure of the gliding components was observed. The wear rate was with 5.62 ± 0.53 mg/million cycles falling within the limit of previous reports for established wear test methods.

  13. CR TKA UHMWPE Wear Tested after Artificial Aging of the Vitamin E Treated Gliding Component by Simulating Daily Patient Activities

    PubMed Central

    Schwiesau, Jens; Fritz, Bernhard; Kutzner, Ines; Bergmann, Georg; Grupp, Thomas M.

    2014-01-01

    The wear behaviour of total knee arthroplasty (TKA) is dominated by two wear mechanisms: the abrasive wear and the delamination of the gliding components, where the second is strongly linked to aging processes and stress concentration in the material. The addition of vitamin E to the bulk material is a potential way to reduce the aging processes. This study evaluates the wear behaviour and delamination susceptibility of the gliding components of a vitamin E blended, ultra-high molecular weight polyethylene (UHMWPE) cruciate retaining (CR) total knee arthroplasty. Daily activities such as level walking, ascending and descending stairs, bending of the knee, and sitting and rising from a chair were simulated with a data set received from an instrumented knee prosthesis. After 5 million test cycles no structural failure of the gliding components was observed. The wear rate was with 5.62 ± 0.53 mg/million cycles falling within the limit of previous reports for established wear test methods. PMID:25506594

  14. Wear of ultra-high molecular weight polyethylene against damaged and undamaged stainless steel and diamond-like carbon-coated counterfaces.

    PubMed

    Firkins, P; Hailey, J L; Fisher, J; Lettington, A H; Butter, R

    1998-10-01

    The wear of ultra-high molecular weight polyethylene (UHMWPE) in artificial joints and the resulting wear debris-induced osteolysis remains a major clinical concern in the orthopaedic sector. Third-body damage of metallic femoral heads is often cited as a cause of accelerated polyethylene wear, and the use of ceramic femoral heads in the hip is gaining increasing favour. In the knee prostheses and for smaller diameter femoral heads, the application of hard surface coatings, such as diamond-like carbon, is receiving considerable attention. However, to date, there has been little or no investigation of the tribology of these coatings in simulated biological environments. In this study, diamond-like carbon (DLC) has been compared to stainless steel in its undamaged form and following simulated third-body damage. The wear of UHMWPE was found to be similar when sliding against undamaged DLC and stainless steel counterfaces. DLC was found to be much more damage resistant than DLC. Under test conditions that simulate third-body damage to the femoral head, the wear of UHMWPE was seven times lower against DLC than against stainless steel (P < 0.05). The study shows DLC has considerable potential as a femoral bearing surface in artificial joints.

  15. On the debris-level origins of adhesive wear

    NASA Astrophysics Data System (ADS)

    Aghababaei, Ramin; Warner, Derek H.; Molinari, Jean-François

    2017-07-01

    Every contacting surface inevitably experiences wear. Predicting the exact amount of material loss due to wear relies on empirical data and cannot be obtained from any physical model. Here, we analyze and quantify wear at the most fundamental level, i.e., wear debris particles. Our simulations show that the asperity junction size dictates the debris volume, revealing the origins of the long-standing hypothesized correlation between the wear volume and the real contact area. No correlation, however, is found between the debris volume and the normal applied force at the debris level. Alternatively, we show that the junction size controls the tangential force and sliding distance such that their product, i.e., the tangential work, is always proportional to the debris volume, with a proportionality constant of 1 over the junction shear strength. This study provides an estimation of the debris volume without any empirical factor, resulting in a wear coefficient of unity at the debris level. Discrepant microscopic and macroscopic wear observations and models are then contextualized on the basis of this understanding. This finding offers a way to characterize the wear volume in atomistic simulations and atomic force microscope wear experiments. It also provides a fundamental basis for predicting the wear coefficient for sliding rough contacts, given the statistics of junction clusters sizes.

  16. On the debris-level origins of adhesive wear.

    PubMed

    Aghababaei, Ramin; Warner, Derek H; Molinari, Jean-François

    2017-07-25

    Every contacting surface inevitably experiences wear. Predicting the exact amount of material loss due to wear relies on empirical data and cannot be obtained from any physical model. Here, we analyze and quantify wear at the most fundamental level, i.e., wear debris particles. Our simulations show that the asperity junction size dictates the debris volume, revealing the origins of the long-standing hypothesized correlation between the wear volume and the real contact area. No correlation, however, is found between the debris volume and the normal applied force at the debris level. Alternatively, we show that the junction size controls the tangential force and sliding distance such that their product, i.e., the tangential work, is always proportional to the debris volume, with a proportionality constant of 1 over the junction shear strength. This study provides an estimation of the debris volume without any empirical factor, resulting in a wear coefficient of unity at the debris level. Discrepant microscopic and macroscopic wear observations and models are then contextualized on the basis of this understanding. This finding offers a way to characterize the wear volume in atomistic simulations and atomic force microscope wear experiments. It also provides a fundamental basis for predicting the wear coefficient for sliding rough contacts, given the statistics of junction clusters sizes.

  17. On the debris-level origins of adhesive wear

    PubMed Central

    Warner, Derek H.; Molinari, Jean-François

    2017-01-01

    Every contacting surface inevitably experiences wear. Predicting the exact amount of material loss due to wear relies on empirical data and cannot be obtained from any physical model. Here, we analyze and quantify wear at the most fundamental level, i.e., wear debris particles. Our simulations show that the asperity junction size dictates the debris volume, revealing the origins of the long-standing hypothesized correlation between the wear volume and the real contact area. No correlation, however, is found between the debris volume and the normal applied force at the debris level. Alternatively, we show that the junction size controls the tangential force and sliding distance such that their product, i.e., the tangential work, is always proportional to the debris volume, with a proportionality constant of 1 over the junction shear strength. This study provides an estimation of the debris volume without any empirical factor, resulting in a wear coefficient of unity at the debris level. Discrepant microscopic and macroscopic wear observations and models are then contextualized on the basis of this understanding. This finding offers a way to characterize the wear volume in atomistic simulations and atomic force microscope wear experiments. It also provides a fundamental basis for predicting the wear coefficient for sliding rough contacts, given the statistics of junction clusters sizes. PMID:28696291

  18. An in vitro assessment of the effect of load and pH on wear between opposing enamel and dentine surfaces.

    PubMed

    Ranjitkar, Sarbin; Kaidonis, John A; Townsend, Grant C; Vu, Anh M; Richards, Lindsay C

    2008-11-01

    Previous in vitro studies have described the wear characteristics of specimens in which enamel has been opposed to enamel and dentine opposed to dentine. The aim of this study was to assess the characteristics of wear between specimens in which enamel was opposed to dentine at loads simulating attrition and at pH values simulating different erosive environments. It was hypothesized that enamel would wear more slowly than dentine under all conditions. Opposing enamel and dentine specimens from 57 human third molar teeth were worn in electromechanical machines with various loads (32, 62 and 100 N) and lubricants (pH 1.2, 3.0 and 6.1). Tooth wear was quantified by measuring reduction in dentine volume over time using a 3D profilometer. Qualitative assessment was also carried out using scanning electron microscopy. Dentine wear increased with increasing load, and dentine wear was faster at pH 1.2 than at pH 3.0 or 6.1 for all loads tested. Interestingly, enamel wore more rapidly than dentine at pH 1.2 under all loads. At pH values of 3.0 and 6.1, enamel wear rates were not measurably different from zero and they were less than wear rates for opposing dentine specimens at all loads. Micrographic assessment showed extensive surface destruction of dentine wear facets due to erosion at pH 1.2. Dentine wear facets were smoother at pH 3.0 that at pH 6.1. When enamel wears against dentine in an acidic environment enamel will wear more rapidly at very low pH, while under less acid conditions dentine will wear faster than enamel.

  19. Study on torsional fretting wear behavior of a ball-on-socket contact configuration simulating an artificial cervical disk.

    PubMed

    Wang, Song; Wang, Fei; Liao, Zhenhua; Wang, Qingliang; Liu, Yuhong; Liu, Weiqiang

    2015-10-01

    A ball-on-socket contact configuration was designed to simulate an artificial cervical disk in structure. UHMWPE (ultra high molecular weight polyethylene) hot pressed by powders and Ti6Al4V alloy were selected as the material combination of ball and socket. The socket surface was coated by a ~500 nm C-DLC (carbon ion implantation-diamond like carbon) mixed layer to improve its surface nano hardness and wear resistance. The torsional fretting wear behavior of the ball-on-socket model was tested at different angular displacements under 25% bovine serum lubrication with an axial force of 100 N to obtain more realistic results with that in vivo. The fretting running regimes and wear damage characteristics as well as wear mechanisms for both ball and socket were studied based on 2D (two dimension) optical microscope, SEM (scanning electron microscope) and 3D (three dimension) profiles. With the increase of angular displacement amplitude from 1° to 7°, three types of T-θ (Torsional torque-angular displacement amplitude) curves (i.e., linear, elliptical and parallelogram loops) corresponding to running regimes of PSR (partial slip regime), MR (mixed regime) and SR (slip regime) were observed and analyzed. Both the central region and the edge zone of the ball and socket were damaged. The worn surfaces were characterized by wear scratches and wear debris. In addition, more severe wear damage and more wear debris appeared on the central region of the socket at higher angular displacement amplitude. The dominant damage mechanism was a mix of surface scratch, adhesive wear and abrasive wear for the UHMWPE ball while that for the coated socket was abrasive wear by PE particles and some polishing and rolling process on the raised overgrown DLC grains. The frictional kinetic behavior, wear type, damage region and damage mechanism for the ball-on-socket model revealed significant differences with those of a ball-on-flat contact while showing better consistency with that of in vitro cervical prosthesis simulations according to the literature. Copyright © 2015. Published by Elsevier B.V.

  20. Effect of acetabular cup abduction angle on wear of ultrahigh-molecular-weight polyethylene in hip simulator testing.

    PubMed

    Korduba, Laryssa A; Essner, Aaron; Pivec, Robert; Lancin, Perry; Mont, Michael A; Wang, Aiguo; Delanois, Ronald E

    2014-10-01

    The effect of acetabular component positioning on the wear rates of metal-on-polyethylene articulations has not been extensively studied. Placement of acetabular cups at abduction angles of more than 40° has been noted as a possible reason for early failure caused by increased wear. We conducted a study to evaluate the effects of different acetabular cup abduction angles on polyethylene wear rate, wear area, contact pressure, and contact area. Our in vitro study used a hip joint simulator and finite element analysis to assess the effects of cup orientation at 4 angles (0°, 40°, 50°, 70°) on wear and contact properties. Polyethylene bearings with 28-mm cobalt-chrome femoral heads were cycled in an environment mimicking in vivo joint fluid to determine the volumetric wear rate after 10 million cycles. Contact pressure and contact area for each cup abduction angle were assessed using finite element analysis. Results were correlated with cup abduction angles to determine if there were any differences among the 4 groups. The inverse relationship between volumetric wear rate and acetabular cup inclination angle demonstrated less wear with steeper cup angles. The largest abduction angle (70°) had the lowest contact area, largest contact pressure, and smallest head coverage. Conversely, the smallest abduction angle (0°) had the most wear and most head coverage. Polyethylene wear after total hip arthroplasty is a major cause of osteolysis and aseptic loosening, which may lead to premature implant failure. Several studies have found that high wear rates for cups oriented at steep angles contributed to their failure. Our data demonstrated that larger cup abduction angles were associated with lower, not higher, wear. However, this potentially "protective" effect is likely counteracted by other complications of steep cup angles, including impingement, instability, and edge loading. These factors may be more relevant in explaining why implants fail at a higher rate if cups are oriented at more than 40° of abduction.

  1. Cross-Shear Implementation in Sliding-Distance-Coupled Finite Element Analysis of Wear in Metal-on-Polyethylene Total Joint Arthroplasty: Intervertebral Total Disc Replacement as an Illustrative Application

    PubMed Central

    Goreham-Voss, Curtis M.; Hyde, Philip J.; Hall, Richard M.; Fisher, John; Brown, Thomas D.

    2010-01-01

    Computational simulations of wear of orthopaedic total joint replacement implants have proven to valuably complement laboratory physical simulators, for pre-clinical estimation of abrasive/adhesive wear propensity. This class of numerical formulations has primarily involved implementation of the Archard/Lancaster relationship, with local wear computed as the product of (finite element) contact stress, sliding speed, and a bearing-couple-dependent wear factor. The present study introduces an augmentation, whereby the influence of interface cross-shearing motion transverse to the prevailing molecular orientation of the polyethylene articular surface is taken into account in assigning the instantaneous local wear factor. The formulation augment is implemented within a widely-utilized commercial finite element software environment (ABAQUS). Using a contemporary metal-on-polyethylene total disc replacement (ProDisc-L) as an illustrative implant, physically validated computational results are presented to document the role of cross-shearing effects in alternative laboratory consensus testing protocols. Going forward, this formulation permits systematically accounting for cross-shear effects in parametric computational wear studies of metal-on-polyethylene joint replacements, heretofore a substantial limitation of such analyses. PMID:20399432

  2. Validation of a 3D CT method for measurement of linear wear of acetabular cups.

    PubMed

    Jedenmalm, Anneli; Nilsson, Fritjof; Noz, Marilyn E; Green, Douglas D; Gedde, Ulf W; Clarke, Ian C; Stark, Andreas; Maguire, Gerald Q; Zeleznik, Michael P; Olivecrona, Henrik

    2011-02-01

    We evaluated the accuracy and repeatability of a 3D method for polyethylene acetabular cup wear measurements using computed tomography (CT). We propose that the method be used for clinical in vivo assessment of wear in acetabular cups. Ultra-high molecular weight polyethylene cups with a titanium mesh molded on the outside were subjected to wear using a hip simulator. Before and after wear, they were (1) imaged with a CT scanner using a phantom model device, (2) measured using a coordinate measurement machine (CMM), and (3) weighed. CMM was used as the reference method for measurement of femoral head penetration into the cup and for comparison with CT, and gravimetric measurements were used as a reference for both CT and CMM. Femoral head penetration and wear vector angle were studied. The head diameters were also measured with both CMM and CT. The repeatability of the method proposed was evaluated with two repeated measurements using different positions of the phantom in the CT scanner. The accuracy of the 3D CT method for evaluation of linear wear was 0.51 mm and the repeatability was 0.39 mm. Repeatability for wear vector angle was 17°. This study of metal-meshed hip-simulated acetabular cups shows that CT has the capacity for reliable measurement of linear wear of acetabular cups at a clinically relevant level of accuracy.

  3. Backside Wear Analysis of Retrieved Acetabular Liners with a Press-Fit Locking Mechanism in Comparison to Wear Simulation In Vitro.

    PubMed

    Puente Reyna, Ana Laura; Jäger, Marcus; Floerkemeier, Thilo; Frecher, Sven; Delank, Karl-Stefan; Schilling, Christoph; Grupp, Thomas M

    2016-01-01

    Backside wear due to micromotion and poor conformity between the liner and its titanium alloy shell may contribute to the high rates of retroacetabular osteolysis and consequent aseptic loosening. The purpose of our study was to understand the wear process on the backside of polyethylene liners from two acetabular cup systems, whose locking mechanism is based on a press-fit cone in combination with a rough titanium conical inner surface on the fixation area. A direct comparison between in vitro wear simulator tests (equivalent to 3 years of use) and retrieved liners (average 13.1 months in situ) was done in order to evaluate the backside wear characteristics and behavior of these systems. Similar wear scores between in vitro tested and retrieved liners were observed. The results showed that this locking mechanism did not significantly produce wear marks at the backside of the polyethylene liners due to micromotion. In all the analyzed liners, the most common wear modes observed were small scratches at the cranial fixation zone directly below the rough titanium inner surface of the shell. It was concluded that most of the wear marks were produced during the insertion and removal of the liner, rather than during its time in situ.

  4. Definition and evaluation of testing scenarios for knee wear simulation under conditions of highly demanding daily activities.

    PubMed

    Schwiesau, Jens; Schilling, Carolin; Kaddick, Christian; Utzschneider, Sandra; Jansson, Volkmar; Fritz, Bernhard; Blömer, Wilhelm; Grupp, Thomas M

    2013-05-01

    The objective of our study was the definition of testing scenarios for knee wear simulation under various highly demanding daily activities of patients after total knee arthroplasty. This was mainly based on a review of published data on knee kinematics and kinetics followed by the evaluation of the accuracy and precision of a new experimental setup. We combined tibio-femoral load and kinematic data reported in the literature to develop deep squatting loading profiles for simulator input. A servo-hydraulic knee wear simulator was customised with a capability of a maximum flexion of 120°, a tibio-femoral load of 5000N, an anterior-posterior (AP) shear force of ±1000N and an internal-external (IE) rotational torque of ±50Nm to simulate highly demanding patient activities. During the evaluation of the newly configurated simulator the ability of the test machine to apply the required load and torque profiles and the flexion kinematics in a precise manner was examined by nominal-actual profile comparisons monitored periodically during subsequent knee wear simulation. For the flexion kinematics under displacement control a delayed actuator response of approximately 0.05s was inevitable due to the inertia of masses in movement of the coupled knee wear stations 1-3 during all applied activities. The axial load and IE torque is applied in an effective manner without substantial deviations between nominal and actual load and torque profiles. During the first third of the motion cycle a marked deviation between nominal and actual AP shear load profiles has to be noticed but without any expected measurable effect on the latter wear simulation due to the fact that the load values are well within the peak magnitude of the nominal load amplitude. In conclusion the described testing method will be an important tool to have more realistic knee wear simulations based on load conditions of the knee joint during activities of daily living. Copyright © 2012 IPEM. Published by Elsevier Ltd. All rights reserved.

  5. Wear of human enamel: a quantitative in vitro assessment.

    PubMed

    Kaidonis, J A; Richards, L C; Townsend, G C; Tansley, G D

    1998-12-01

    Many factors influence the extent and rate at which enamel wears. Clinical studies in humans are limited by difficulties in the accurate quantification of intra-oral wear and by a lack of control over the oral environment. The purpose of this study was to determine the wear characteristics of human dental enamel under controlled experimental conditions. An electro-mechanical tooth wear machine, in which opposing enamel surfaces of sectioned, extracted teeth were worn under various conditions, was used to simulate tooth grinding or bruxism. Enamel surface wear was quantified by weight to an accuracy of 0.1 mg, with water uptake and loss controlled. The variables considered included the structure and hardness of enamel, facet area, duration of tooth contact, relative speed of opposing surfaces, temperature, load, pH, and the nature of the lubricant. Enamel wear under non-lubricated conditions increased with increasing load over the range of 1.7 to 16.2 kg. The addition of a liquid lubricant (pH = 7) reduced enamel wear up to 6.7 kg, but when the load increased above this threshold, the rate of wear increased dramatically. With the viscosity of the lubricant constant and pH = 3, the rate of wear was further reduced to less than 10% of the non-lubricated rate at 9.95 kg, after which the rate again increased substantially. Under more extreme conditions (pH = 1.2, simulating gastric acids), the wear was excessive under all experimental loads. When saliva was used as a lubricant, the amount of wear was relatively low at 9.95 kg, but rapid wear occurred at 14.2 kg and above. These results indicate that under non-lubricated conditions, enamel wear remains low at high loads due to the dry-lubricating capabilities of fine enamel powder. Under lubricated conditions, low loads with an acidic lubricant lead to little enamel wear, whereas very low pH results in a high rate of wear under all loads.

  6. Wear resistance of ductile irons

    NASA Astrophysics Data System (ADS)

    Lerner, Y. S.

    1994-06-01

    This study was undertaken to evaluate the wear resistance of different grades of ductile iron as alterna-tives to high- tensile- strength alloyed and inoculated gray irons and bronzes for machine- tool and high-pressure hydraulic components. Special test methods were employed to simulate typical conditions of reciprocating sliding wear with and without abrasive- contaminated lubricant for machine and press guideways. Quantitative relationships were established among wear rate, microstructure and micro-hardness of structural constituents, and nodule size of ductile iron. The frictional wear resistance of duc-tile iron as a bearing material was tested with hardened steel shafts using standard test techniques under continuous rotating movement with lubricant. Lubricated sliding wear tests on specimens and compo-nents for hydraulic equipment and apparatus were carried out on a special rig with reciprocating motion, simulating the working conditions in a piston/cylinder unit in a pressure range from 5 to 32 MPa. Rig and field tests on machine- tool components and units and on hydraulic parts have confirmed the test data.

  7. Predicting knee replacement damage in a simulator machine using a computational model with a consistent wear factor.

    PubMed

    Zhao, Dong; Sakoda, Hideyuki; Sawyer, W Gregory; Banks, Scott A; Fregly, Benjamin J

    2008-02-01

    Wear of ultrahigh molecular weight polyethylene remains a primary factor limiting the longevity of total knee replacements (TKRs). However, wear testing on a simulator machine is time consuming and expensive, making it impractical for iterative design purposes. The objectives of this paper were first, to evaluate whether a computational model using a wear factor consistent with the TKR material pair can predict accurate TKR damage measured in a simulator machine, and second, to investigate how choice of surface evolution method (fixed or variable step) and material model (linear or nonlinear) affect the prediction. An iterative computational damage model was constructed for a commercial knee implant in an AMTI simulator machine. The damage model combined a dynamic contact model with a surface evolution model to predict how wear plus creep progressively alter tibial insert geometry over multiple simulations. The computational framework was validated by predicting wear in a cylinder-on-plate system for which an analytical solution was derived. The implant damage model was evaluated for 5 million cycles of simulated gait using damage measurements made on the same implant in an AMTI machine. Using a pin-on-plate wear factor for the same material pair as the implant, the model predicted tibial insert wear volume to within 2% error and damage depths and areas to within 18% and 10% error, respectively. Choice of material model had little influence, while inclusion of surface evolution affected damage depth and area but not wear volume predictions. Surface evolution method was important only during the initial cycles, where variable step was needed to capture rapid geometry changes due to the creep. Overall, our results indicate that accurate TKR damage predictions can be made with a computational model using a constant wear factor obtained from pin-on-plate tests for the same material pair, and furthermore, that surface evolution method matters only during the initial "break in" period of the simulation.

  8. Importance of preclinical evaluation of wear in hip implant designs using simulator machines.

    PubMed

    Trommer, Rafael Mello; Maru, Márcia Marie

    2017-01-01

    Total hip arthroplasty (THA) is a surgical procedure that involves the replacement of the damaged joint of the hip by an artificial device. Despite the recognized clinical success of hip implants, wear of the articulating surfaces remains as one of the critical issues influencing performance. Common material combinations used in hip designs comprise metal-on-polymer (MoP), ceramic-on-polymer (CoP), metal-on-metal (MoM), and ceramic-on-ceramic (CoC). However, when the design of the hip implant is concerned besides the materials used, several parameters can influence its wear performance. In this scenario, where the safety and efficacy for the patient are the main issues, it is fundamental to evaluate and predict the wear rate of the hip implant design before its use in THA. This is one of the issues that should be taken into account in the preclinical evaluation step of the product, in which simulated laboratory tests are necessary. However, it is fundamental that the applied motions and loads can reproduce the wear mechanisms physiologically observed in the patient. To replicate the in vivo angular displacements and loadings, special machines known as joint simulators are employed. This article focuses on the main characteristics related to the wear simulation of hip implants using mechanical simulators, giving information to surgeons, researchers, regulatory bodies, etc., about the importance of preclinical wear evaluation. A critical analysis is performed on the differences in the principles of operation of simulators and their effects on the final results, and about future trends in wear simulation.

  9. Study on Abrasive Wear of Brake Pad in the Large-megawatt Wind Turbine Brake Based on Deform Software

    NASA Astrophysics Data System (ADS)

    Zhang, Shengfang; Hao, Qiang; Sha, Zhihua; Yin, Jian; Ma, Fujian; Liu, Yu

    2017-12-01

    For the friction and wear issues of brake pads in the large-megawatt wind turbine brake during braking, this paper established the micro finite element model of abrasive wear by using Deform-2D software. Based on abrasive wear theory and considered the variation of the velocity and load in the micro friction and wear process, the Archard wear calculation model is developed. The influence rules of relative sliding velocity and friction coefficient in the brake pad and disc is analysed. The simulation results showed that as the relative sliding velocity increases, the wear will be more serious, while the larger friction coefficient lowered the contact pressure which released the wear of the brake pad.

  10. Analysis of particle size to erosion wear of sliding sleeve ball seat based on fluent software

    NASA Astrophysics Data System (ADS)

    Ding, Kun; Yin, Hongcheng; Wan, Bingqian; Cheng, Hao; Xiang, Lu; Li, Jianmin

    2017-04-01

    The fracturing has become the most offensive stimulation treatment in the low permeability reservoir. But, as the construction displacement and sand dosage of overlong horizontal well were increased continuously, the erosion wear of ball seat of pitching sliding sleeve was increasingly serious, which might lead to the failure of opening the sliding sleeve. In the existing literature, there were many researches on the erosion wear of liquid-solid two-phase flow in the diameter of sudden expansion pipe, but the influence of solid particle with mixed particle size to the erosion wear was not considered. This paper studied the erosion wear of ball seat according to the mixed proppant with different particle sizes, and carried out the numerical simulation with Fluent software with the Euler two-fluid theory. The results showed that: the erosion wear rate of ball seat is in inversely proportional to the particle size of proppant; the erosion wear rate of ball seat is different when the volume fraction of proppant with different particle sizes is changed; and for the mixed proppant of which the particle size is 0.3mm and 0.8mm, the erosion wear rate of ball seat is minimum when the volume fraction of proppant, of which the particle size is 0.3mm, is about 20%. The simulated result contributed to the deep study on erosion wear law of solid particle, and meanwhile, provided a certain reference basis for the selection of staged fracturing material of horizontal well.

  11. Validation of a 3D CT method for measurement of linear wear of acetabular cups

    PubMed Central

    2011-01-01

    Background We evaluated the accuracy and repeatability of a 3D method for polyethylene acetabular cup wear measurements using computed tomography (CT). We propose that the method be used for clinical in vivo assessment of wear in acetabular cups. Material and methods Ultra-high molecular weight polyethylene cups with a titanium mesh molded on the outside were subjected to wear using a hip simulator. Before and after wear, they were (1) imaged with a CT scanner using a phantom model device, (2) measured using a coordinate measurement machine (CMM), and (3) weighed. CMM was used as the reference method for measurement of femoral head penetration into the cup and for comparison with CT, and gravimetric measurements were used as a reference for both CT and CMM. Femoral head penetration and wear vector angle were studied. The head diameters were also measured with both CMM and CT. The repeatability of the method proposed was evaluated with two repeated measurements using different positions of the phantom in the CT scanner. Results The accuracy of the 3D CT method for evaluation of linear wear was 0.51 mm and the repeatability was 0.39 mm. Repeatability for wear vector angle was 17°. Interpretation This study of metal-meshed hip-simulated acetabular cups shows that CT has the capacity for reliable measurement of linear wear of acetabular cups at a clinically relevant level of accuracy. PMID:21281259

  12. The Interaction of the Space Shuttle Launch and Entry Suits and Sustained Weightless on Astronaut Egress Locomotion

    NASA Technical Reports Server (NTRS)

    Greenisen, M. C.; Bishop, P. A.; Sothmann, M.

    2008-01-01

    The purpose of this study was to determine the consequences of extended periods of weightlessness during space missions on astronauts f ability to perform a simulated contingency egress while wearing either of the Launch and Entry suits immediately after space flight. In our previous lab-based study of simulated contingency egress, we found only 4 of 12 non-astronauts wearing the Launch and Entry Suit (LES) successfully completed the simulated egress. However, 4 of 4 of the previous failures (when tested wearing the LES), were then successful in completing the test wearing the Advanced Crew Escape Suit (ACES). Therefore, this study tested 21 Astronaut Volunteers wearing either the LES or ACES while performing a simulated egress on a treadmill (TM) onboard the Crew Transportation Vehicle immediately after space flight at either the Kennedy Space Center or Edwards AFB. Astronauts walked for 400 meters at 1.6m/sec with g-suit inflation level set to preflight testing levels, visor down, breathing from the suit emergency O2 supply. Metabolic, heartrate, and perceived exertion data were collected during these post-flight tests. Exactly the same preflight simulated egress tests on a TM were performed in the lab at NASA/JSC by each crewmember at L-60. Preflight testing found 2 of the 21 crewmembers were unable to complete the simulated contingency egress. Postflight, 9 crew (8 ACES, 1 LES) completed the simulated contingency egress of 400 meters at 1.6m/sec. and 12 failed to meet that standard (7 ACES, 5 LES). Preflight physiological response tests failed to identify crew capable of performing the egress vs. those who failed. However, 18 of the 21 crew did make at least 2.67 minutes into the postflight egress testing. At that point in time, heartrate was higher (P <=.20) for the failures compared to the finishers. These findings indicate that NASA fs switch to the ACES for space flight crews should be expedited.

  13. Influence of switches and crossings on wheel profile evolution in freight vehicles

    NASA Astrophysics Data System (ADS)

    Casanueva, Carlos; Doulgerakis, Emmanouil; Jönsson, Per-Anders; Stichel, Sebastian

    2014-05-01

    Wheel reprofiling costs for freight vehicles are a major issue in Sweden, reducing the profitability of freight traffic operations and therefore hindering the modal shift needed for achieving reduced emissions. In order to understand the damage modes in freight vehicles, uniform wear prediction with Archard's wear law has been studied in a two-axle timber transport wagon, and simulation results have been compared to measurements. Challenges of wheel wear prediction in freight wagons are discussed, including the influence of block brakes and switches and crossings. The latter have a major influence on the profile evolution of this case study, so specific simulations are performed and a thorough discussion is carried out.

  14. The in vitro wear behavior of experimental resin-based composites derived from a commercial formulation.

    PubMed

    Finlay, Nessa; Hahnel, Sebastian; Dowling, Adam H; Fleming, Garry J P

    2013-04-01

    To investigate the short- and long-term in vitro wear resistance of experimental resin-based composites (RBCs) derived from a commercial formulation. Six experimental RBCs were manufactured by manipulating the monomeric resin composition and the filler characteristics of Grandio (Voco GmbH, Cuxhaven, Germany). The Oregon Health Sciences University (OHSU) oral wear simulator was used in the presence of a food-like slurry to simulate three-body abrasion and attrition wear for 50,000, 150,000 and 300,000 cycles. A three-dimensional image of each wear facet was created and the total volumetric wear (mm(3)) and maximum wear depth (μm) were quantified for the RBC and antagonist. Statistical analyses of the total volumetric wear and maximum wear depth data (two- and one-way analyses of variance (ANOVA), with Tukey's post hoc tests where required) and regression analyses, were conducted at p=0.05. Two-way ANOVAs identified a significant effect of RBC material×wear cycles, RBC material and wear cycles (all p<0.0001). Regression analyses showed significant increases in the total volumetric wear (p≤0.001) and maximum wear depth data (p≤0.004) for all RBCs with increasing wear cycles. Differences between all RBC materials were evident after ≥150,000 wear cycles and antagonist wear provided valuable information to support the experimental findings. Wear simulating machines can provide an indication of the clinical performance but clinical performance is multi-factorial and wear is only a single facet. Employing experimental RBCs provided by a dental manufacturer rather than using self-manufactured RBCs or dental products provides increased experimental control by limiting the variables involved. Copyright © 2013 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  15. [An experimental study of the wear behavior of dental feldspathic glass-ceramic and lithium disilicate glass-ceramic].

    PubMed

    Tian, Bei-min; Zhang, Shao-feng; He, Lin; Guo, Jia-wen; Yu, Jin-tao; Wu, Xiao-hong

    2013-11-01

    To investigate the tribology characteristics of two ceramic materials in vitro:feldspathic glass-ceramic (veneer porcelain) and lithium disilicate glass-ceramic (heat-pressed ceramic), and to evaluate the wear resistance of different ceramic materials from the dynamic chewing perspective. Wear tests were performed in simulated oral environment with stainless steel ball antagonists (r = 3 mm), veneer porcelain (CERAMCO 3) and heat-pressed ceramic (IPS e.max Press HT type) in the chewing simulator. The tribological tests were carried out under artificial saliva lubrication condition in room temperature with a vertical load of 10 N for 1.2×10(6) cycles (f = 1.5 Hz, uniform circular motion, revolving speed = 90 r/min, radius = 0.5 mm). The wear volumes were measured using three-dimensional profiling, and surface microscopic morphology were observed using scanning electron microscopy at time point of 200 000, 400 000, 600 000, 800 000, 1 000 000, and 1 200 000 cycles. In a simulated oral environment, the wear rates of veneer porcelain were (0.001 20 ± 0.00 018) , (0.000 10 ± 0.000 03) , (0.000 50 ± 0.000 05), (0.000 10 ± 0.000 02) , (0.004 10 ± 0.000 38) , and (0.019 00 ± 0.003 53) (×10(-4) mm(3)/cycles) at 200 000, 400 000, 600 000, 800 000, 1 000 000, 1 200 000 cycles. The wear rates of heat-pressed ceramic were (0.139 50 ± 0.030 94), (0.124 40 ± 0.031 20), (0.054 80 ± 0.005 38), (0.038 80 ± 0.006 10), (0.011 10 ± 0.003 75), (0.198 90 ± 0.045 80) (×10(-4) mm(3)/cycles) at 200 000, 400 000, 600 000, 800 000, 1 000 000, 1 200 000 cycles. Three stages were observed in the wear loss process of the two materials: running-in stage, steady wear stage and severe wear stage. In running-in and steady wear stage, the shallow wear tracks of veneer porcelain were produced by the fatigue effect.While in severe wear stage, the wear tracks turned into ploughing. In running-in stage, the surface of heat-pressed ceramic was characterized by dense and shallow ploughing. In steady wear stage, the wear tracks turned into flake peeling produced by fatigue effect. At last, the whole layer was worn off by the effects of ploughing. In a simulated oral environment, the wear rate and wear loss of heat-pressed ceramic are greater than that of veneer porcelain.

  16. Micro-wear features on unique 100-Mrad cups: two retrieved cups compared to hip simulator wear study.

    PubMed

    Yamamoto, Kengo; Masaoka, Toshinori; Manaka, Masakazu; Oonishi, Hironobu; Clarke, Ian; Shoji, Hiromu; Kawanabe, Keiichi; Imakiire, Atsuhiro

    2004-04-01

    We studied the micro-wear phenomena of unique, extensively cross-linked polyethylene cups (cross-linked with 1,000 kGy-irradiation) that had been used briefly in Japan. Two retrievals (at 15 years) came from the Japanese "SOM" hip system (implanted 1971-78). These were compared to a set of 0 kGy and 500-1,500 kGy cups run in our hip simulator. The polyethylene cups that had not been cross-linked had the greatest wear. The worn areas had a burnished appearance and were clearly separated from the unworn region by a distinct ridge-line. The worn areas had lost all machine tracks, showed a large amount of UHMWPE 'flow', and long PE fibrils. The associated surface rippling was degraded. These features were considered synonymous with severe polyethylene wear. In contrast, the worn areas in the very cross-linked cups had a visibly matte surface and no ridge-line. Micro-examination showed that the machine tracks were still present. Ripple formations were less obvious than in the cups that were not cross-linked, polyethylene surface fibrils were scarcer and all the fibrils were much smaller than in the cups that were not crosslinked. Our two retrieved cups and the simulator cups confirmed the greater wear-resistance of very cross-linked polyethylene. It should also be noted that the SOM cup design and processing were unique and differed greatly from that of modern polyethylene cups.

  17. The effect of 'running-in' on the tribology and surface morphology of metal-on-metal Birmingham hip resurfacing device in simulator studies.

    PubMed

    Vassiliou, K; Elfick, A P D; Scholes, S C; Unsworth, A

    2006-02-01

    It is well documented that hard bearing combinations show a running-in phenomenon in vitro and there is also some evidence of this from retrieval studies. In order to investigate this phenomenon, five Birmingham hip resurfacing devices were tested in a hip wear simulator. One of these (joint 1) was also tested in a friction simulator before, during, and after the wear test and surface analysis was conducted throughout portions of the testing. The wear showed the classical running in with the wear rate falling from 1.84 mm3 per 10(6) cycles for the first 10(6) cycles of testing to 0.24 mm3 per 10(6) cycles over the final 2 x 10(6) cycles of testing. The friction tests suggested boundary lubrication initially, but at 1 x 10(6) cycles a mixed lubrication regime was evident. By 2 x 10(6) cycles the classical Stribeck curve had formed, indicating a considerable contribution from the fluid film at higher viscosities. This continued to be evident at both 3 x 10(6) and 5 x 10(6) cycles. The surface study complements these findings.

  18. Mechanism-Based FE Simulation of Tool Wear in Diamond Drilling of SiCp/Al Composites.

    PubMed

    Xiang, Junfeng; Pang, Siqin; Xie, Lijing; Gao, Feinong; Hu, Xin; Yi, Jie; Hu, Fang

    2018-02-07

    The aim of this work is to analyze the micro mechanisms underlying the wear of macroscale tools during diamond machining of SiC p /Al6063 composites and to develop the mechanism-based diamond wear model in relation to the dominant wear behaviors. During drilling, high volume fraction SiC p /Al6063 composites containing Cu, the dominant wear mechanisms of diamond tool involve thermodynamically activated physicochemical wear due to diamond-graphite transformation catalyzed by Cu in air atmosphere and mechanically driven abrasive wear due to high-frequency scrape of hard SiC reinforcement on tool surface. An analytical diamond wear model, coupling Usui abrasive wear model and Arrhenius extended graphitization wear model was proposed and implemented through a user-defined subroutine for tool wear estimates. Tool wear estimate in diamond drilling of SiC p /Al6063 composites was achieved by incorporating the combined abrasive-chemical tool wear subroutine into the coupled thermomechanical FE model of 3D drilling. The developed drilling FE model for reproducing diamond tool wear was validated for feasibility and reliability by comparing numerically simulated tool wear morphology and experimentally observed results after drilling a hole using brazed polycrystalline diamond (PCD) and chemical vapor deposition (CVD) diamond coated tools. A fairly good agreement of experimental and simulated results in cutting forces, chip and tool wear morphologies demonstrates that the developed 3D drilling FE model, combined with a subroutine for diamond tool wear estimate can provide a more accurate analysis not only in cutting forces and chip shape but also in tool wear behavior during drilling SiC p /Al6063 composites. Once validated and calibrated, the developed diamond tool wear model in conjunction with other machining FE models can be easily extended to the investigation of tool wear evolution with various diamond tool geometries and other machining processes in cutting different workpiece materials.

  19. Mechanism-Based FE Simulation of Tool Wear in Diamond Drilling of SiCp/Al Composites

    PubMed Central

    Xiang, Junfeng; Pang, Siqin; Xie, Lijing; Gao, Feinong; Hu, Xin; Yi, Jie; Hu, Fang

    2018-01-01

    The aim of this work is to analyze the micro mechanisms underlying the wear of macroscale tools during diamond machining of SiCp/Al6063 composites and to develop the mechanism-based diamond wear model in relation to the dominant wear behaviors. During drilling, high volume fraction SiCp/Al6063 composites containing Cu, the dominant wear mechanisms of diamond tool involve thermodynamically activated physicochemical wear due to diamond-graphite transformation catalyzed by Cu in air atmosphere and mechanically driven abrasive wear due to high-frequency scrape of hard SiC reinforcement on tool surface. An analytical diamond wear model, coupling Usui abrasive wear model and Arrhenius extended graphitization wear model was proposed and implemented through a user-defined subroutine for tool wear estimates. Tool wear estimate in diamond drilling of SiCp/Al6063 composites was achieved by incorporating the combined abrasive-chemical tool wear subroutine into the coupled thermomechanical FE model of 3D drilling. The developed drilling FE model for reproducing diamond tool wear was validated for feasibility and reliability by comparing numerically simulated tool wear morphology and experimentally observed results after drilling a hole using brazed polycrystalline diamond (PCD) and chemical vapor deposition (CVD) diamond coated tools. A fairly good agreement of experimental and simulated results in cutting forces, chip and tool wear morphologies demonstrates that the developed 3D drilling FE model, combined with a subroutine for diamond tool wear estimate can provide a more accurate analysis not only in cutting forces and chip shape but also in tool wear behavior during drilling SiCp/Al6063 composites. Once validated and calibrated, the developed diamond tool wear model in conjunction with other machining FE models can be easily extended to the investigation of tool wear evolution with various diamond tool geometries and other machining processes in cutting different workpiece materials. PMID:29414839

  20. Effect of wear on the burst strength of l-80 steel casing

    NASA Astrophysics Data System (ADS)

    Irawan, S.; Bharadwaj, A. M.; Temesgen, B.; Karuppanan, S.; Abdullah, M. Z. B.

    2015-12-01

    Casing wear has recently become one of the areas of research interest in the oil and gas industry especially in extended reach well drilling. The burst strength of a worn out casing is one of the significantly affected mechanical properties and is yet an area where less research is done The most commonly used equations to calculate the resulting burst strength after wear are Barlow, the initial yield burst, the full yield burst and the rupture burst equations. The objective of this study was to estimate casing burst strength after wear through Finite Element Analysis (FEA). It included calculation and comparison of the different theoretical bursts pressures with the simulation results along with effect of different wear shapes on L-80 casing material. The von Misses stress was used in the estimation of the burst pressure. The result obtained shows that the casing burst strength decreases as the wear percentage increases. Moreover, the burst strength value of the casing obtained from the FEA has a higher value compared to the theoretical burst strength values. Casing with crescent shaped wear give the highest burst strength value when simulated under nonlinear analysis.

  1. A new method for shape and texture classification of orthopedic wear nanoparticles.

    PubMed

    Zhang, Dongning; Page, Janet R; Kavanaugh, Aaron E; Billi, Fabrizio

    2012-09-27

    Detailed morphologic analysis of particles produced during wear of orthopedic implants is important in determining a correlation among material, wear, and biological effects. However, the use of simple shape descriptors is insufficient to categorize the data and to compare the nature of wear particles generated by different implants. An approach based on Discrete Fourier Transform (DFT) is presented for describing particle shape and surface texture. Four metal-on-metal bearing couples were tested in an orbital wear simulator under standard and adverse (steep-angled cups) wear simulator conditions. Digitized Scanning Electron Microscope (SEM) images of the wear particles were imported into MATLAB to carry out Fourier descriptor calculations via a specifically developed algorithm. The descriptors were then used for studying particle characteristics (shape and texture) as well as for cluster classification. Analysis of the particles demonstrated the validity of the proposed model by showing that steep-angle Co-Cr wear particles were more asymmetric, compressed, extended, triangular, square, and roughened at 3 Mc than after 0.25 Mc. In contrast, particles from standard angle samples were only more compressed and extended after 3 Mc compared to 0.25 Mc. Cluster analysis revealed that the 0.25 Mc steep-angle particle distribution was a subset of the 3 Mc distribution.

  2. Wheel life prediction model - an alternative to the FASTSIM algorithm for RCF

    NASA Astrophysics Data System (ADS)

    Hossein-Nia, Saeed; Sichani, Matin Sh.; Stichel, Sebastian; Casanueva, Carlos

    2018-07-01

    In this article, a wheel life prediction model considering wear and rolling contact fatigue (RCF) is developed and applied to a heavy-haul locomotive. For wear calculations, a methodology based on Archard's wear calculation theory is used. The simulated wear depth is compared with profile measurements within 100,000 km. For RCF, a shakedown-based theory is applied locally, using the FaStrip algorithm to estimate the tangential stresses instead of FASTSIM. The differences between the two algorithms on damage prediction models are studied. The running distance between the two reprofiling due to RCF is estimated based on a Wöhler-like relationship developed from laboratory test results from the literature and the Palmgren-Miner rule. The simulated crack locations and their angles are compared with a five-year field study. Calculations to study the effects of electro-dynamic braking, track gauge, harder wheel material and the increase of axle load on the wheel life are also carried out.

  3. The design and development of a triaxial wear-testing joint simulator.

    PubMed

    Green, A S; O'Connell, M K; Lyons, A S; James, S P

    1999-01-01

    Most of the existing wear testers created to wear test total hip replacements, specifically the acetabular component, are designed to exert only an axial force and provide rotation in a close approximation of the actual femoral movement. The Rocky Mountain Joint Simulator was designed to exert three orthogonal forces and provide rotations about the X-, Y- and Z-axes to more closely simulate the physiological forces and motions found in the human gait cycle. The RMJS was also designed with adaptability for other joints, such as knees or canine hips, through the use of hydraulics and a computer-programmable control system. Such adaptability and functionality allows the researcher to more closely model a gait cycle, thereby obtaining wear patterns that resemble those found in retrieved implants more closely than existing simulators. Research is ongoing into the tuning and evaluation of the machine and preliminary acetabular component wear test results will be presented at the conference.

  4. Increased conformity offers diminishing returns for reducing total knee replacement wear.

    PubMed

    Fregly, Benjamin J; Marquez-Barrientos, Carlos; Banks, Scott A; DesJardins, John D

    2010-02-01

    Wear remains a significant problem limiting the lifespan of total knee replacements (TKRs). Though increased conformity between TKR components has the potential to decrease wear, the optimal amount and planes of conformity have not been investigated. Furthermore, differing conformities in the medial and lateral compartments may provide designers the opportunity to address both wear and kinematic design goals simultaneously. This study used a computational model of a Stanmore knee simulator machine and a previously validated wear model to investigate this issue for simulated gait. TKR geometries with different amounts and planes of conformity on the medial and lateral sides were created and tested in two phases. The first phase utilized a wide range of sagittal and coronal conformity combinations to blanket a physically realistic design space. The second phase performed a focused investigation of the conformity conditions from the first phase to which predicted wear volume was sensitive. For the first phase, sagittal but not coronal conformity was found to have a significant effect on predicted wear volume. For the second phase, increased sagittal conformity was found to decrease predicted wear volume in a nonlinear fashion, with reductions gradually diminishing as conformity increased. These results suggest that TKR geometric design efforts aimed at minimizing wear should focus on sagittal rather than coronal conformity and that at least moderate sagittal conformity is desirable in both compartments.

  5. Critical length scale controls adhesive wear mechanisms

    PubMed Central

    Aghababaei, Ramin; Warner, Derek H.; Molinari, Jean-Francois

    2016-01-01

    The adhesive wear process remains one of the least understood areas of mechanics. While it has long been established that adhesive wear is a direct result of contacting surface asperities, an agreed upon understanding of how contacting asperities lead to wear debris particle has remained elusive. This has restricted adhesive wear prediction to empirical models with limited transferability. Here we show that discrepant observations and predictions of two distinct adhesive wear mechanisms can be reconciled into a unified framework. Using atomistic simulations with model interatomic potentials, we reveal a transition in the asperity wear mechanism when contact junctions fall below a critical length scale. A simple analytic model is formulated to predict the transition in both the simulation results and experiments. This new understanding may help expand use of computer modelling to explore adhesive wear processes and to advance physics-based wear laws without empirical coefficients. PMID:27264270

  6. Evaluation of composite wear with a new multi-mode oral wear simulator.

    PubMed

    Condon, J R; Ferracane, J L

    1996-07-01

    The goals of this study were to develop a machine which simultaneously produces wear through the two main oral wear mechanisms of abrasion and attrition by the action of an enamel antagonist and to compare the results obtained for dental composites using this machine to those obtained from clinical studies and other in vitro studies. The accuracy of this new wear tester was determined by examining 11 commercial composite filling materials and 1 amalgam. Specimens were subjected to three-body abrasion and attrition wear for 50,000 cycles. Profilometry was used to quantitate wear of the composites. Linear regression analysis was used to correlate the results to those obtained from clinical studies, as well as from other in vitro wear testers. The area of enamel wear was also determined by image analysis. The SEM was used to evaluate the wear surfaces. The lowest abrasion wear was recorded for the amalgam and for the microfill and smaller-particle composites. Attrition wear was enhanced for the microfill composites and one small-particle hybrid. There was a strong correlation between the results obtained with the new wear tester and those obtained in the clinical trials cited in the literature. Wear of the enamel antagonist was the greatest for the composites with the largest particle sizes. The wear tester showed a reasonable correlation with other wear-producing machines. A new wear tester developed to evaluate and discriminate abrasion and attrition wear provided results similar to those reported in the literature for a variety of commercial composites. The new machine is capable of characterizing the behavior of a material in multiple wear modes simultaneously with one simple, realistic test.

  7. A comparative study of sliding wear of nonmetallic dental restorative materials with emphasis on micromechanical wear mechanisms.

    PubMed

    Dupriez, Nataliya Deyneka; von Koeckritz, Ann-Kristin; Kunzelmann, Karl-Heinz

    2015-05-01

    The purpose of this study is to investigate the in vitro tribological behavior of modern nonmetallic restorative materials. Specimen prepared of IPS e.max Press lithium disilicate glass ceramic, IPS Empress Esthetic leucite-reinforced glass ceramic, Everest ZS Blanks yttria-stabilized zirconia and Lava Ultimate composite were subjected to wear using a wear machine designed to simulate occlusal loads. The wear of the investigated materials and antagonists were evaluated by a three-dimensional surface scanner. The quantitative wear test results were used to compare and rank the materials. Specimens were divided into two groups with steatite and alumina antagonists. For each antagonist material an analysis of variance was applied. As a post hoc test of the significant differences, Tukey's honest significant difference test was used. With steatite antagonist: wear of zirconia < wear of leucite-reinforced ceramic < wear of lithium disilicate ceramic < wear of Lava Ultimate composite. No significant wear difference was found for steatite antagonist. The wear of IPS e.max Press and Lava Ultimate against hard alumina was found to be twice lower as compared to their wear when opposing to steatite. The differences were associated with materials mechanical properties (hardness and fracture toughness) and with materials microstructure. Wear mechanisms are discussed. © 2014 Wiley Periodicals, Inc.

  8. Comparative abrasive wear resistance and surface analysis of dental resin-based materials

    PubMed Central

    Nayyer, Maleeha; Zahid, Shahreen; Hassan, Syed Hammad; Mian, Salman Aziz; Mehmood, Sana; Khan, Haroon Ahmed; Kaleem, Muhammad; Zafar, Muhammad Sohail; Khan, Abdul Samad

    2018-01-01

    Objective: The objective of this study was to assess the surface properties (microhardness and wear resistance) of various composites and compomer materials. In addition, the methodologies used for assessing wear resistance were compared. Materials and Methods: This study was conducted using restorative material (Filtek Z250, Filtek Z350, QuiXfil, SureFil SDR, and Dyract XP) to assess wear resistance. A custom-made toothbrush simulator was employed for wear testing. Before and after wear resistance, structural, surface, and physical properties were assessed using various techniques. Results: Structural changes and mass loss were observed after treatment, whereas no significant difference in terms of microhardness was observed. The correlation between atomic force microscopy (AFM) and profilometer and between wear resistance and filler volume was highly significant. The correlation between wear resistance and microhardness were insignificant. Conclusions: The AFM presented higher precision compared to optical profilometers at a nanoscale level, but both methods can be used in tandem for a more detailed and precise roughness analysis. PMID:29657526

  9. Wear of dental tissues and materials.

    PubMed

    Craig, R G; Powers, J M

    1976-06-01

    Wear may result from physiological or pathological conditions and may be desirable, as in the reduction of an overcontoured restoration, or undesirable as in the production of cervical abrasion cavities. A variety of methods, including clinical testing, the use of wear machines and the measurement of related properties such as hardness or coefficient of friction have been used to investigate wear of tooth tissue and of dental materials. Because these methods may not reveal the nature of the wear process recent work has been directed to the study of surface failure resulting from a single sliding contact. Many clinical studies have been conducted but they are time consuming and difficult to quantify, nor do they allow of evaluation of different parameters contributing to the wear. Laboratory simulation of wear has been shown to be valuable in comparing materials of the same group but between-group comparisons may give anomalous results. The most rewarding studies have been those using a single or small number of passes of a suitable abrading point over the material since these permit determination of the actual process by which wear is produced.

  10. Influence of conformity on the wear of total knee replacement: An experimental study

    PubMed Central

    Brockett, Claire L; Carbone, Silvia; Fisher, John; Jennings, Louise M

    2017-01-01

    Wear of total knee replacement continues to be a significant factor influencing the clinical longevity of implants. Historically, failure due to delamination and fatigue directed design towards more conforming inserts to reduce contact stress. As new generations of more oxidatively stable polyethylene have been developed, more flexibility in bearing design has been introduced. The aim of this study was to investigate the effect of insert conformity on the wear performance of a fixed bearing total knee replacement through experimental simulation. Two geometries of insert were studied under standard gait conditions. There was a significant reduction in wear with reducing implant conformity. This study has demonstrated that bearing conformity has a significant impact on the wear performance of a fixed bearing total knee replacement, providing opportunities to improve clinical performance through enhanced material and design selection. PMID:29251167

  11. Nanoclay-Reinforced Glass-Ionomer Cements: In Vitro Wear Evaluation and Comparison by Two Wear-Test Methods

    PubMed Central

    Fareed, Muhammad A.; Stamboulis, Artemis

    2017-01-01

    Glass ionomer cement (GIC) represents a major transformation in restorative dentistry. Wear of dental restoratives is a common phenomenon and the determination of the wear resistance of direct-restorative materials is a challenging task. The aim of this paper was to evaluate the wear resistance of novel glass ionomer cement by two wear-test methods and to compare the two wear methods.The wear resistance of a conventional glass ionomer cement (HiFi Advanced Health Care Kent, UK) and cements modified by including various percentages of nanoclays (1, 2 and 4 wt %) was measured by a reciprocating wear test (ball-on-flat) and Oregon Health and Sciences University’s (OHSU) wear simulator. The OHSU wear simulation subjected the cement specimens to three wear mechanisms, namely abrasion, three-body abrasion and attrition using a steatite antagonist. The abrasion wear resulted in material loss from GIC specimen as the steatite antagonist forced through the exposed glass particles when it travelled along the sliding path.The hardness of specimens was measured by the Vickers hardness test. The results of reciprocation wear test showed that HiFi-1 resulted in the lowest wear volume 4.90 (0.60) mm3 (p < 0.05), but there was no significant difference (p > 0.05) in the wear volume in comparison to HiFi, HiFi-2 and HiFi-4. Similarly, the results of OHSU wear simulator showed that the total wear volume of HiFi-4 1.49 (0.24) was higher than HiFi-1 and HiFi-2. However, no significant difference (p > 0.05) was found in the OHSU total wear volume in GICs after nanoclay incorporation. The Vickers hardness (HV) of the nanoclay-reinforced cements was measured between 62 and 89 HV. Nanoclay addition at a higher concentration (4%) resulted in higher wear volume and wear depth. The total wear volumes were less dependent upon abrasion volume and attrition volume. The total wear depths were strongly influenced by attrition depth and to some extent by abrasion depth. The addition of nanoclay in higher wt % to HiFi did not result in significant improvement in wear resistance and hardness. Nonetheless, wear is a very complex phenomenon because it is sensitive to a wide number of factors that do not necessarily act in the same way when compared using different parameters. PMID:29563434

  12. Corrosion-wear of β-Ti alloy TMZF (Ti-12Mo-6Zr-2Fe) in simulated body fluid.

    PubMed

    Yang, Xueyuan; Hutchinson, Christopher R

    2016-09-15

    Titanium alloys are popular metallic implant materials for use in total hip replacements. Although, α+β titanium alloys such as Ti-6Al-4V have been the most commonly used alloys, the high Young's modulus (∼110GPa) leads to an undesirable stress shielding effect. An alternative is to use β titanium alloys that exhibit a significantly lower Young's modulus (∼70GPa). Femoral stems made of a β titanium alloy known as TMZF (Ti-12Mo-6Zr-2Fe (wt.%)) have been used as part of modular hip replacements since the early 2000's but these were recalled in 2011 by the US Food & Drug Administration (FDA) due to unacceptable levels of 'wear debris'. The wear was caused by small relative movement of the stem and neck at the junction where they fit together in the modular hip replacement design. In this study, the corrosion and wear properties of the TMZF alloy were investigated in simulated body fluid to identify the reason for the wear debris generation. Ti64 was used as a control for comparison. It is shown that the interaction between the surfaces of Ti64 and TMZF with simulated body fluid is very similar, both from the point of view of the products formed and the kinetics of the reaction. The dry wear behaviour of TMZF is also close to that of Ti64 and consistent with expectations based on Archard's law for abrasive wear. However, wear of Ti64 and TMZF in simulated body fluid show contrasting behaviours. A type of time-dependent wear test is used to examine the synergy between corrosion and wear of TMZF and Ti64. It is shown that the wear of TMZF accelerated rapidly in SBF whereas that of Ti64 is reduced. The critical role of the strain hardening capacity of the two materials and its role in helping the surface resist abrasion by hydroxyapatite particles formed as a result of the reaction with the SBF is discussed and recommendations are made for modifications that could be made to the TMZF alloy to improve the corrosion-wear response. TMZF is a low modulus β-Ti alloy that has been used as the femoral stem in the Stryker modular design total hip replacement. It went into service in the early 2000's but was recalled by the FDA in 2011 due to unacceptable levels of wear debris released in the body which led to adverse physiological reactions. A large number of these implants remain in patients today. In this contribution, we investigate the corrosion (interaction of the alloy with simulated body fluid (SBF)), dry wear and then corrosion-wear in SBF to identify the origin of the unacceptable levels of wear that led to the FDA recall of this material. We use Ti-6Al-4V as a control and demonstrate that the reaction between Ti64 and TMZF with SBF is very similar in terms of both products formed and kinetics. We also show that the dry wear behaviour of TMZF is very similar to that of Ti64 and exactly as should be expected for the hardness of this material. However, the wear behaviours of TMZF and Ti64 are completed different in SBF and wear of TMZF is significantly accelerated in SBF. A type of time-dependent wear test is used to demonstrate the synergy between corrosion and wear and the key role of the strain hardening capacity (or lack thereof in the case of β-Ti) is discussed. Copyright © 2016 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  13. Wear Improvement of Tools in the Cold Forging Process for Long Hex Flange Nuts.

    PubMed

    Hsia, Shao-Yi; Shih, Po-Yueh

    2015-09-25

    Cold forging has played a critical role in fasteners and has been widely used in automotive production, manufacturing, aviation and 3C (Computer, Communication, and Consumer electronics). Despite its extensive use in fastener forming and die design, operator experience and trial and error make it subjective and unreliable owing to the difficulty of controlling the development schedule. This study used finite element analysis to establish and simulate wear in automotive repair fastener manufacturing dies based on actual process conditions. The places on a die that wore most quickly were forecast, with the stress levels obtained being substituted into the Archard equation to calculate die wear. A 19.87% improvement in wear optimization occurred by applying the Taguchi quality method to the new design. Additionally, a comparison of actual manufacturing data to simulations revealed a nut forging size error within 2%, thereby demonstrating the accuracy of this theoretical analysis. Finally, SEM micrographs of the worn surfaces on the upper punch indicate that the primary wear mechanism on the cold forging die for long hex flange nuts was adhesive wear. The results can simplify the development schedule, reduce the number of trials and further enhance production quality and die life.

  14. Wear Improvement of Tools in the Cold Forging Process for Long Hex Flange Nuts

    PubMed Central

    Hsia, Shao-Yi; Shih, Po-Yueh

    2015-01-01

    Cold forging has played a critical role in fasteners and has been widely used in automotive production, manufacturing, aviation and 3C (Computer, Communication, and Consumer electronics). Despite its extensive use in fastener forming and die design, operator experience and trial and error make it subjective and unreliable owing to the difficulty of controlling the development schedule. This study used finite element analysis to establish and simulate wear in automotive repair fastener manufacturing dies based on actual process conditions. The places on a die that wore most quickly were forecast, with the stress levels obtained being substituted into the Archard equation to calculate die wear. A 19.87% improvement in wear optimization occurred by applying the Taguchi quality method to the new design. Additionally, a comparison of actual manufacturing data to simulations revealed a nut forging size error within 2%, thereby demonstrating the accuracy of this theoretical analysis. Finally, SEM micrographs of the worn surfaces on the upper punch indicate that the primary wear mechanism on the cold forging die for long hex flange nuts was adhesive wear. The results can simplify the development schedule, reduce the number of trials and further enhance production quality and die life. PMID:28793589

  15. A novel method for isolation and recovery of ceramic nanoparticles and metal wear debris from serum lubricants at ultra-low wear rates.

    PubMed

    Lal, S; Hall, R M; Tipper, J L

    2016-09-15

    Ceramics have been used to deliver significant improvements in the wear properties of orthopaedic bearing materials, which has made it challenging to isolate wear debris from simulator lubricants. Ceramics such as silicon nitride, as well as ceramic-like surface coatings on metal substrates have been explored as potential alternatives to conventional implant materials. Current isolation methods were designed for isolating conventional metal, UHMWPE and ceramic wear debris. In this paper, we describe a methodology for isolation and recovery of ceramic or ceramic-like coating particles and metal wear particles from serum lubricants under ultra-low and low wear performance. Enzymatic digestion was used to digest the serum proteins and sodium polytungstate was used as a novel density gradient medium to isolate particles from proteins and other contaminants by ultracentrifugation. This method demonstrated over 80% recovery of particles and did not alter the size or morphology of ceramic and metal particles during the isolation process. Improvements in resistance to wear and mechanical damage of the articulating surfaces have a large influence on longevity and reliability of joint replacement devices. Modern ceramics have demonstrated ultra-low wear rates for hard-on-hard total hip replacements. Generation of very low concentrations of wear debris in simulator lubricants has made it challenging to isolate the particles for characterisation and further analysis. We have introduced a novel method to isolate ceramic and metal particles from serum-based lubricants using enzymatic digestion and novel sodium polytungstate gradients. This is the first study to demonstrate the recovery of ceramic and metal particles from serum lubricants at lowest detectable in vitro wear rates reported in literature. Copyright © 2016. Published by Elsevier Ltd.

  16. The Wear Behavior of Textured Steel Sliding against Polymers

    PubMed Central

    Wang, Meiling; Zhang, Changtao; Wang, Xiaolei

    2017-01-01

    Artificially fabricated surface textures can significantly improve the friction and wear resistance of a tribological contact. Recently, this surface texturing technique has been applied to polymer materials to improve their tribological performance. However, the wear behavior of textured tribo-pairs made of steel and polymer materials has been less thoroughly investigated and is not well understood; thus, it needs further research. The aim of this study is to investigate the wear properties of tribological contacts made of textured stainless steel against polymer surfaces. Three polymer materials were selected in this study, namely, ultrahigh molecular weight polyethylene (UHMWPE), polyoxymethylene (POM) and (polyetheretherketone) PEEK. Wear tests were operated through a ring-on-plane mode. The results revealed that the texture features and material properties affected the wear rates and friction coefficients of the textured tribo-pairs. In general, PEEK/textured steel achieved the lowest wear rate among the three types of tribo-pairs investigated. Energy dispersive x-ray spectroscopy (EDX) analysis revealed that the elements of C and O on the contacting counterfaces varied with texture features and indicated different wear behavior. Experimental and simulated results showed differences in the stress distribution around the dimple edge, which may influence wear performance. Wear debris with different surface morphologies were found for tribo-pairs with varying texture features. This study has increased the understanding of the wear behavior of tribo-pairs between textured stainless steel and polymer materials. PMID:28772688

  17. Study on the extrusion of nickel-based spark plug electrodes by numerical simulation

    NASA Astrophysics Data System (ADS)

    Saby, Q.; Courbon, C.; Salvatore, F.; Fabre, D.; Romeyer, F.

    2018-05-01

    Interest in metal forming simulation has grown rapidly during the last decades and is now well established even in industry. It provides a flexible and relatively cheap method to perform sensitivity analyses, getting a better insight into the forming process and use it as an optimisation tool. As far as wear is concerned, numerical simulation can be seen as a relevant approach to assess the thermomechanical loadings applied to the active die surface and therefore predict their wear behaviour. In this study, a Finite-Element (FE) based model has been developed in order to investigate the cold forming process of a nickel-based sparkplug electrode. A fully thermo-mechanically coupled implicit formulation has been used in order to model the forward extrusion step with a special emphasis on the contact conditions at the workpiece-die interface. Contact pressure, relative sliding velocity and temperature profiles have been extracted versus time and qualitatively compared to the wear phenomena observed on the worn production dies.

  18. Unicompartmental knee prostheses: in vitro wear assessment of the menisci tibial insert after two different fixation methods

    NASA Astrophysics Data System (ADS)

    Affatato, S.; Spinelli, M.; Zavalloni, M.; Carmignato, S.; Lopomo, N.; Marcacci, M.; Viceconti, M.

    2008-10-01

    Knee osteoarthritis is a complex clinical scenario where many biological and mechanical factors influence the severity of articular degenerative changes. Minimally invasive knee prosthetic surgery, with only a compartment replacement (unicompartmental knee replacement), might be a good compromise between osteotomy and total knee prosthesis. The focus of this study was to develop and validate a protocol to assess the fixation method of the femoral components in mechanical simulation, for pre-clinical validation; the wear behaviour of two different fixation frames was quantified and compared. In particular, two different wear tests were conducted using the same knee simulator, the same load profiles and the same kinematics; two different fixation methods were applied to the femoral sleds (synthetic femur and metal block). Surface characterization on both articulating bearings was performed by a roughness measuring machine and coordinate measuring machine. The wear produced by the tibial inserts using the synthetic femur was considerably higher than the wear registered by the metal-block holder. Roughness measurements on femoral sleds showed a limited number of scratches with high Rt values for the metal-block set-up; the damaged surface broadened in the case of femoral condyles and tibial inserts mounted on composite bone, but lower Rt and linear penetration values were measured. The two holding frames showed different wear activities as a consequence of dissimilar dynamic performance. Further observations should be made in vivo to prove the actual importance of synthetic bone simulations and specific material behaviour.

  19. Tribological investigations of the load, temperature, and time dependence of wear in sliding contact.

    PubMed

    Marko, Matthew David; Kyle, Jonathan P; Wang, Yuanyuan Sabrina; Terrell, Elon J

    2017-01-01

    An effort was made to study and characterize the evolution of transient tribological wear in the presence of sliding contact. Sliding contact is often characterized experimentally via the standard ASTM D4172 four-ball test, and these tests were conducted for varying times ranging from 10 seconds to 1 hour, as well as at varying temperatures and loads. A numerical model was developed to simulate the evolution of wear in the elastohydrodynamic regime. This model uses the results of a Monte Carlo study to develop novel empirical equations for wear rate as a function of asperity height and lubricant thickness; these equations closely represented the experimental data and successfully modeled the sliding contact.

  20. Analysis about diamond tool wear in nano-metric cutting of single crystal silicon using molecular dynamics method

    NASA Astrophysics Data System (ADS)

    Wang, Zhiguo; Liang, Yingchun; Chen, Mingjun; Tong, Zhen; Chen, Jiaxuan

    2010-10-01

    Tool wear not only changes its geometry accuracy and integrity, but also decrease machining precision and surface integrity of workpiece that affect using performance and service life of workpiece in ultra-precision machining. Scholars made a lot of experimental researches and stimulant analyses, but there is a great difference on the wear mechanism, especially on the nano-scale wear mechanism. In this paper, the three-dimensional simulation model is built to simulate nano-metric cutting of a single crystal silicon with a non-rigid right-angle diamond tool with 0 rake angle and 0 clearance angle by the molecular dynamics (MD) simulation approach, which is used to investigate the diamond tool wear during the nano-metric cutting process. A Tersoff potential is employed for the interaction between carbon-carbon atoms, silicon-silicon atoms and carbon-silicon atoms. The tool gets the high alternating shear stress, the tool wear firstly presents at the cutting edge where intension is low. At the corner the tool is splitted along the {1 1 1} crystal plane, which forms the tipping. The wear at the flank face is the structure transformation of diamond that the diamond structure transforms into the sheet graphite structure. Owing to the tool wear the cutting force increases.

  1. A comparison between electromechanical and pneumatic-controlled knee simulators for the investigation of wear of total knee replacements.

    PubMed

    Abdelgaied, Abdellatif; Fisher, John; Jennings, Louise M

    2017-07-01

    More robust preclinical experimental wear simulation methods are required in order to simulate a wider range of activities, observed in different patient populations such as younger more active patients, as well as to fully meet and be capable of going well beyond the existing requirements of the relevant international standards. A new six-station electromechanically driven simulator (Simulation Solutions, UK) with five fully independently controlled axes of articulation for each station, capable of replicating deep knee bending as well as other adverse conditions, which can be operated in either force or displacement control with improved input kinematic following, has been developed to meet these requirements. This study investigated the wear of a fixed-bearing total knee replacement using this electromechanically driven fully independent knee simulator and compared it to previous data from a predominantly pneumatically controlled simulator in which each station was not fully independently controlled. In addition, the kinematic performance and the repeatability of the simulators have been investigated and compared to the international standard requirements. The wear rates from the electromechanical and pneumatic knee simulators were not significantly different, with wear rates of 2.6 ± 0.9 and 2.7 ± 0.9 mm 3 /million cycles (MC; mean ± 95% confidence interval, p = 0.99) and 5.4 ± 1.4 and 6.7 ± 1.5 mm 3 /MC (mean ± 95 confidence interval, p = 0.54) from the electromechanical and pneumatic simulators under intermediate levels (maximum 5 mm) and high levels (maximum 10 mm) of anterior-posterior displacements, respectively. However, the output kinematic profiles of the control system, which drive the motion of the simulator, followed the input kinematic profiles more closely on the electromechanical simulator than the pneumatic simulator. In addition, the electromechanical simulator was capable of following kinematic and loading input cycles within the tolerances of the international standard requirements (ISO 14243-3). The new-generation electromechanical knee simulator with fully independent control has the potential to be used for a much wider range of kinematic conditions, including high-flexion and other severe conditions, due to its improved capability and performance in comparison to the previously used pneumatic-controlled simulators.

  2. A comparison between electromechanical and pneumatic-controlled knee simulators for the investigation of wear of total knee replacements

    PubMed Central

    Abdelgaied, Abdellatif; Fisher, John; Jennings, Louise M

    2017-01-01

    More robust preclinical experimental wear simulation methods are required in order to simulate a wider range of activities, observed in different patient populations such as younger more active patients, as well as to fully meet and be capable of going well beyond the existing requirements of the relevant international standards. A new six-station electromechanically driven simulator (Simulation Solutions, UK) with five fully independently controlled axes of articulation for each station, capable of replicating deep knee bending as well as other adverse conditions, which can be operated in either force or displacement control with improved input kinematic following, has been developed to meet these requirements. This study investigated the wear of a fixed-bearing total knee replacement using this electromechanically driven fully independent knee simulator and compared it to previous data from a predominantly pneumatically controlled simulator in which each station was not fully independently controlled. In addition, the kinematic performance and the repeatability of the simulators have been investigated and compared to the international standard requirements. The wear rates from the electromechanical and pneumatic knee simulators were not significantly different, with wear rates of 2.6 ± 0.9 and 2.7 ± 0.9 mm3/million cycles (MC; mean ± 95% confidence interval, p = 0.99) and 5.4 ± 1.4 and 6.7 ± 1.5 mm3/MC (mean ± 95 confidence interval, p = 0.54) from the electromechanical and pneumatic simulators under intermediate levels (maximum 5 mm) and high levels (maximum 10 mm) of anterior–posterior displacements, respectively. However, the output kinematic profiles of the control system, which drive the motion of the simulator, followed the input kinematic profiles more closely on the electromechanical simulator than the pneumatic simulator. In addition, the electromechanical simulator was capable of following kinematic and loading input cycles within the tolerances of the international standard requirements (ISO 14243-3). The new-generation electromechanical knee simulator with fully independent control has the potential to be used for a much wider range of kinematic conditions, including high-flexion and other severe conditions, due to its improved capability and performance in comparison to the previously used pneumatic-controlled simulators. PMID:28661228

  3. Deformation of the Durom Acetabular Component and Its Impact on Tribology in a Cadaveric Model—A Simulator Study

    PubMed Central

    Gu, Yanqing; Wang, Qing; Cui, Weiding; Fan, Weimin

    2012-01-01

    Background Recent studies have shown that the acetabular component frequently becomes deformed during press-fit insertion. The aim of this study was to explore the deformation of the Durom cup after implantation and to clarify the impact of deformation on wear and ion release of the Durom large head metal-on-metal (MOM) total hips in simulators. Methods Six Durom cups impacted into reamed acetabula of fresh cadavers were used as the experimental group and another 6 size-paired intact Durom cups constituted the control group. All 12 Durom MOM total hips were put through a 3 million cycle (MC) wear test in simulators. Results The 6 cups in the experimental group were all deformed, with a mean deformation of 41.78±8.86 µm. The average volumetric wear rate in the experimental group and in the control group in the first million cycle was 6.65±0.29 mm3/MC and 0.89±0.04 mm3/MC (t = 48.43, p = 0.000). The ion levels of Cr and Co in the experimental group were also higher than those in the control group before 2.0 MC. However there was no difference in the ion levels between 2.0 and 3.0 MC. Conclusions This finding implies that the non-modular acetabular component of Durom total hip prosthesis is likely to become deformed during press-fit insertion, and that the deformation will result in increased volumetric wear and increased ion release. Clinical Relevance This study was determined to explore the deformation of the Durom cup after implantation and to clarify the impact of deformation on wear and ion release of the prosthesis. Deformation of the cup after implantation increases the wear of MOM bearings and the resulting ion levels. The clinical use of the Durom large head prosthesis should be with great care. PMID:23144694

  4. Deformation of the Durom acetabular component and its impact on tribology in a cadaveric model--a simulator study.

    PubMed

    Liu, Feng; Chen, Zhefeng; Gu, Yanqing; Wang, Qing; Cui, Weiding; Fan, Weimin

    2012-01-01

    Recent studies have shown that the acetabular component frequently becomes deformed during press-fit insertion. The aim of this study was to explore the deformation of the Durom cup after implantation and to clarify the impact of deformation on wear and ion release of the Durom large head metal-on-metal (MOM) total hips in simulators. Six Durom cups impacted into reamed acetabula of fresh cadavers were used as the experimental group and another 6 size-paired intact Durom cups constituted the control group. All 12 Durom MOM total hips were put through a 3 million cycle (MC) wear test in simulators. The 6 cups in the experimental group were all deformed, with a mean deformation of 41.78 ± 8.86 µm. The average volumetric wear rate in the experimental group and in the control group in the first million cycle was 6.65 ± 0.29 mm(3)/MC and 0.89 ± 0.04 mm(3)/MC (t = 48.43, p = 0.000). The ion levels of Cr and Co in the experimental group were also higher than those in the control group before 2.0 MC. However there was no difference in the ion levels between 2.0 and 3.0 MC. This finding implies that the non-modular acetabular component of Durom total hip prosthesis is likely to become deformed during press-fit insertion, and that the deformation will result in increased volumetric wear and increased ion release. This study was determined to explore the deformation of the Durom cup after implantation and to clarify the impact of deformation on wear and ion release of the prosthesis. Deformation of the cup after implantation increases the wear of MOM bearings and the resulting ion levels. The clinical use of the Durom large head prosthesis should be with great care.

  5. Asperity-Level Origins of Transition from Mild to Severe Wear

    NASA Astrophysics Data System (ADS)

    Aghababaei, Ramin; Brink, Tobias; Molinari, Jean-François

    2018-05-01

    Wear is the inevitable damage process of surfaces during sliding contact. According to the well-known Archard's wear law, the wear volume scales with the real contact area and as a result is proportional to the load. Decades of wear experiments, however, show that this relation only holds up to a certain load limit, above which the linearity is broken and a transition from mild to severe wear occurs. We investigate the microscopic origins of this breakdown and the corresponding wear transition at the asperity level. Our atomistic simulations reveal that the interaction between subsurface stress fields of neighboring contact spots promotes the transition from mild to severe wear. The results show that this interaction triggers the deep propagation of subsurface cracks and the eventual formation of large debris particles, with a size corresponding to the apparent contact area of neighboring contact spots. This observation explains the breakdown of the linear relation between the wear volume and the normal load in the severe wear regime. This new understanding highlights the critical importance of studying contact beyond the elastic limit and single-asperity models.

  6. Special cluster issue on tribocorrosion of dental materials

    NASA Astrophysics Data System (ADS)

    Mathew, Mathew T.; Stack, Margaret M.

    2013-10-01

    Tribocorrosion affects all walks of life from oil and gas conversion to biomedical materials. Wear can interact with corrosion to enhance it or impede it; conversely, corrosion can enhance or impede wear. The understanding of the interactions between physical and chemical phenomena has been greatly assisted by electrochemical and microscopic techniques. In dentistry, it is well recognized that erosion due to dissolution (a term physicists use to denote wear) of enamel can result in tooth decay; however, the effects of the oral environment, i.e. pH levels, electrochemical potential and any interactions due to the forces involved in chewing are not well understood. This special cluster issue includes investigations on the fundamentals of wear-corrosion interactions involved in simulated oral environments, including candidate dental implant and veneer materials. The issue commences with a fundamental study of titanium implants and this is followed by an analysis of the behaviour of commonly used temporomandibular devices in a synovial fluid-like environment. The analysis of tribocorrosion mechanisms of Ti6Al4V biomedical alloys in artificial saliva with different pHs is addressed and is followed by a paper on fretting wear, on hydroxyapatite-titanium composites in simulated body fluid, supplemented with protein (bovine serum albumin). The effects of acid treatments on tooth enamel, and as a surface engineering technique for dental implants, are investigated in two further contributions. An analysis of the physiological parameters of intraoral wear is addressed; this is followed by a study of candidate dental materials in common beverages such as tea and coffee with varying acidity and viscosity and the use of wear maps to identify the safety zones for prediction of material degradation in such conditions. Hence, the special cluster issue consists of a range of tribocorrosion contributions involving many aspects of dental tribocorrosion, from analysis of physiological approaches and tissue engineering to studying of the effects of the environments encountered in clinical practice and management which lead to tooth decay. A wide range of analytical techniques and tribocorrosion experimental approaches is used to simulate, assess and model the synergistic interactions of wear and corrosion, many of them leading to new insights. We hope it will lead to increased awareness of tribocorrosion phenomena for researchers and dental clinicians alike and 'food for thought' for further studies in this field.

  7. Simple geometry tribological study of osteochondral graft implantation in the knee.

    PubMed

    Bowland, Philippa; Ingham, Eileen; Fisher, John; Jennings, Louise M

    2018-03-01

    Robust preclinical test methods involving tribological simulations are required to investigate and understand the tribological function of osteochondral repair interventions in natural knee tissues. The aim of this study was to investigate the effects of osteochondral allograft implantation on the local tribology (friction, surface damage, wear and deformation) of the tissues in the natural knee joint using a simple geometry, reciprocating pin-on-plate friction simulator. In addition, the study aimed to assess the ability of osteochondral grafts to restore a low surface damage, deformation and wear articulation when compared to the native state. A method was developed to characterise and quantify surface damage wear and deformation of the opposing cartilage-bone pin surface using a non-contacting optical profiler (Alicona Infinite Focus). Porcine 12 mm diameter cartilage-bone pins were reciprocated against bovine cartilage-bone plates that had 6 mm diameter osteochondral allografts, cartilage defects or stainless steel pins (positive controls) inserted centrally. Increased levels of surface damage with changes in geometry were not associated with significant increases in the coefficient of dynamic friction. Significant damage to the opposing cartilage surface was observed in the positive control groups. Cartilage damage, deformation and wear (as measured by change in geometry) in the xenograft (2.4 mm 3 ) and cartilage defect (0.99 mm 3 ) groups were low and not significantly different (p > 0.05) compared to the negative control in either group. The study demonstrated the potential of osteochondral grafts to restore the congruent articular surface and biphasic tribology of the natural joint. An optical method has been developed to characterise cartilage wear, damage and deformation that can be applied to the tribological assessment of osteochondral grafts in a whole natural knee joint simulation model.

  8. Simple geometry tribological study of osteochondral graft implantation in the knee

    PubMed Central

    Bowland, Philippa; Ingham, Eileen; Fisher, John; Jennings, Louise M

    2018-01-01

    Robust preclinical test methods involving tribological simulations are required to investigate and understand the tribological function of osteochondral repair interventions in natural knee tissues. The aim of this study was to investigate the effects of osteochondral allograft implantation on the local tribology (friction, surface damage, wear and deformation) of the tissues in the natural knee joint using a simple geometry, reciprocating pin-on-plate friction simulator. In addition, the study aimed to assess the ability of osteochondral grafts to restore a low surface damage, deformation and wear articulation when compared to the native state. A method was developed to characterise and quantify surface damage wear and deformation of the opposing cartilage-bone pin surface using a non-contacting optical profiler (Alicona Infinite Focus). Porcine 12 mm diameter cartilage-bone pins were reciprocated against bovine cartilage-bone plates that had 6 mm diameter osteochondral allografts, cartilage defects or stainless steel pins (positive controls) inserted centrally. Increased levels of surface damage with changes in geometry were not associated with significant increases in the coefficient of dynamic friction. Significant damage to the opposing cartilage surface was observed in the positive control groups. Cartilage damage, deformation and wear (as measured by change in geometry) in the xenograft (2.4 mm3) and cartilage defect (0.99 mm3) groups were low and not significantly different (p > 0.05) compared to the negative control in either group. The study demonstrated the potential of osteochondral grafts to restore the congruent articular surface and biphasic tribology of the natural joint. An optical method has been developed to characterise cartilage wear, damage and deformation that can be applied to the tribological assessment of osteochondral grafts in a whole natural knee joint simulation model. PMID:29375001

  9. PMMA Third-Body Wear after Unicondylar Knee Arthroplasty Decuples the UHMWPE Wear Particle Generation In Vitro

    PubMed Central

    Paulus, Alexander Christoph; Franke, Manja; Kraxenberger, Michael; Schröder, Christian; Jansson, Volkmar

    2015-01-01

    Introduction. Overlooked polymethylmethacrylate after unicondylar knee arthroplasty can be a potential problem, since this might influence the generated wear particle size and morphology. The aim of this study was the analysis of polyethylene wear in a knee wear simulator for changes in size, morphology, and particle number after the addition of third-bodies. Material and Methods. Fixed bearing unicondylar knee prostheses (UKA) were tested in a knee simulator for 5.0 million cycles. Following bone particles were added for 1.5 million cycles, followed by 1.5 million cycles with PMMA particles. A particle analysis by scanning electron microscopy of the lubricant after the cycles was performed. Size and morphology of the generated wear were characterized. Further, the number of particles per 1 million cycles was calculated for each group. Results. The particles of all groups were similar in size and shape. The number of particles in the PMMA group showed 10-fold higher values than in the bone and control group (PMMA: 10.251 × 1012; bone: 1.145 × 1012; control: 1.804 × 1012). Conclusion. The addition of bone or PMMA particles in terms of a third-body wear results in no change of particle size and morphology. PMMA third-bodies generated tenfold elevated particle numbers. This could favor an early aseptic loosening. PMID:25866795

  10. Numerical and experimental investigations for the evaluation of the wear coefficient of reverse total shoulder prostheses.

    PubMed

    Mattei, Lorenza; Di Puccio, Francesca; Joyce, Thomas J; Ciulli, Enrico

    2015-03-01

    In the present study, numerical and experimental wear investigations on reverse total shoulder arthroplasties (RTSAs) were combined in order to estimate specific wear coefficients, currently not available in the literature. A wear model previously developed by the authors for metal-on-plastic hip implants was adapted to RTSAs and applied in a double direction: firstly, to evaluate specific wear coefficients for RTSAs from experimental results and secondly, to predict wear distribution. In both cases, the Archard wear law (AR) and the wear law of UHMWPE (PE) were considered, assuming four different k functions. The results indicated that both the wear laws predict higher wear coefficients for RTSA with respect to hip implants, particularly the AR law, with k values higher than twofold the hip ones. Such differences can significantly affect predictive wear model results for RTSA, when non-specific wear coefficients are used. Moreover, the wear maps simulated with the two laws are markedly different, although providing the same wear volume. A higher wear depth (+51%) is obtained with the AR law, located at the dome of the cup, while with the PE law the most worn region is close to the edge. Taking advantage of the linear trend of experimental volume losses, the wear coefficients obtained with the AR law should be valid despite having neglected the geometry update in the model. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. The influence of malalignment and ageing following sterilisation by gamma irradiation in an inert atmosphere on the wear of ultra-high-molecular-weight polyethylene in patellofemoral replacements

    PubMed Central

    Maiti, Raman; Cowie, Raelene M; Fisher, John; Jennings, Louise M

    2017-01-01

    Complications of patellofemoral arthroplasty often occur soon after implantation and, as well as other factors, can be due to the design of the implant or its surgical positioning. A number of studies have previously considered the wear of ultra-high-molecular-weight polyethylene patellae following suboptimal implantation; however, studies have primarily been carried out under a limited number of degrees of freedom. The aim of this study was to develop a protocol to assess the wear of patellae under a malaligned condition in a six-axis patellofemoral joint simulator. The malalignment protocol hindered the tracking of the patella centrally in the trochlear groove and imparted a constant 5° external rotation (tilt) on the patella button. Following 3 million cycles of wear simulation, this condition had no influence on the wear of ultra-high-molecular-weight polyethylene patellae aged for 4 years compared to well-positioned non-aged implants (p > 0.05). However, under the malaligned condition, ultra-high-molecular-weight polyethylene patellae aged 8–10 years after unpacking (following sterilisation by gamma irradiation in an inert atmosphere) and worn ultra-high-molecular-weight polyethylene components also aged 4 years after unpacking (following the same sterilisation process) exhibited a high rate of wear. Fatigue failure due to elevated contact stress led to delamination of the ultra-high-molecular-weight polyethylene and in some cases complete failure of the patellae. The results suggest that suboptimal tracking of the patella in the trochlear groove and tilt of the patella button could have a significant effect on the wear of ultra-high-molecular-weight polyethylene and could lead to implant failure. PMID:28661229

  12. The influence of malalignment and ageing following sterilisation by gamma irradiation in an inert atmosphere on the wear of ultra-high-molecular-weight polyethylene in patellofemoral replacements.

    PubMed

    Maiti, Raman; Cowie, Raelene M; Fisher, John; Jennings, Louise M

    2017-07-01

    Complications of patellofemoral arthroplasty often occur soon after implantation and, as well as other factors, can be due to the design of the implant or its surgical positioning. A number of studies have previously considered the wear of ultra-high-molecular-weight polyethylene patellae following suboptimal implantation; however, studies have primarily been carried out under a limited number of degrees of freedom. The aim of this study was to develop a protocol to assess the wear of patellae under a malaligned condition in a six-axis patellofemoral joint simulator. The malalignment protocol hindered the tracking of the patella centrally in the trochlear groove and imparted a constant 5° external rotation (tilt) on the patella button. Following 3 million cycles of wear simulation, this condition had no influence on the wear of ultra-high-molecular-weight polyethylene patellae aged for 4 years compared to well-positioned non-aged implants (p > 0.05). However, under the malaligned condition, ultra-high-molecular-weight polyethylene patellae aged 8-10 years after unpacking (following sterilisation by gamma irradiation in an inert atmosphere) and worn ultra-high-molecular-weight polyethylene components also aged 4 years after unpacking (following the same sterilisation process) exhibited a high rate of wear. Fatigue failure due to elevated contact stress led to delamination of the ultra-high-molecular-weight polyethylene and in some cases complete failure of the patellae. The results suggest that suboptimal tracking of the patella in the trochlear groove and tilt of the patella button could have a significant effect on the wear of ultra-high-molecular-weight polyethylene and could lead to implant failure.

  13. Quantification of Wear and Deformation in Different Configurations of Polyethylene Acetabular Cups Using Micro X-ray Computed Tomography

    PubMed Central

    Affatato, Saverio; Zanini, Filippo; Carmignato, Simone

    2017-01-01

    Wear is currently quantified as mass loss of the bearing materials measured using gravimetric methods. However, this method does not provide other information, such as volumetric loss or surface deviation. In this work, we validated a technique to quantify polyethylene wear in three different batches of ultrahigh-molecular-polyethylene acetabular cups used for hip implants using nondestructive microcomputed tomography. Three different configurations of polyethylene acetabular cups, previously tested under the ISO 14242 parameters, were tested on a hip simulator for an additional 2 million cycles using a modified ISO 14242 load waveform. In this context, a new approach was proposed in order to simulate, on a hip joint simulator, high-demand activities. In addition, the effects of these activities were analyzed in terms of wear and deformations of those polyethylenes by means of gravimetric method and micro X-ray computed tomography. In particular, while the gravimetric method was used for weight loss assessment, microcomputed tomography allowed for acquisition of additional quantitative information about the evolution of local wear and deformation through three-dimensional surface deviation maps for the entire cups’ surface. Experimental results showed that the wear and deformation behavior of these materials change according to different mechanical simulations. PMID:28772616

  14. PEEK-OPTIMA™ as an alternative to cobalt chrome in the femoral component of total knee replacement: A preliminary study

    PubMed Central

    Cowie, Raelene M; Briscoe, Adam; Fisher, John; Jennings, Louise M

    2016-01-01

    PEEK-OPTIMA™ (Invibio Ltd, UK) has been considered as an alternative joint arthroplasty bearing material due to its favourable mechanical properties and the biocompatibility of its wear debris. In this study, the potential to use injection moulded PEEK-OPTIMA™ as an alternative to cobalt chrome in the femoral component of a total knee replacement was investigated in terms of its wear performance. Experimental wear simulation of three cobalt chrome and three PEEK-OPTIMA™ femoral components articulating against all-polyethylene tibial components was carried out under two kinematic conditions: 3 million cycles under intermediate kinematics (maximum anterior-posterior displacement of 5 mm) followed by 3 million cycles under high kinematic conditions (anterior-posterior displacement 10 mm). The wear of the GUR1020 ultra-high-molecular-weight polyethylene tibial components was assessed by gravimetric analysis; for both material combinations under each kinematic condition, the mean wear rates were low, that is, below 5 mm3/million cycles. Specifically, under intermediate kinematic conditions, the wear rate of the ultra-high-molecular-weight polyethylene tibial components was 0.96 ± 2.26 mm3/million cycles and 2.44 ± 0.78 mm3/million cycle against cobalt chrome and PEEK-OPTIMA™ implants, respectively (p = 0.06); under high kinematic conditions, the wear rates were 2.23 ± 1.85 mm3/million cycles and 4.44 ± 2.35 mm3/million cycles, respectively (p = 0.03). Following wear simulation, scratches were apparent on the surface of the PEEK-OPTIMA™ femoral components. The surface topography of the femoral components was assessed using contacting profilometry and showed a statistically significant increase in measured surface roughness of the PEEK-OPTIMA™ femoral components compared to the cobalt chrome implants. However, this did not appear to influence the wear rate, which remained linear over the duration of the study. These preliminary findings showed that PEEK-OPTIMA™ gives promise as an alternative bearing material to cobalt chrome alloy in the femoral component of a total knee replacement with respect to wear performance. PMID:27637723

  15. Quantification of the effect of cross-shear and applied nominal contact pressure on the wear of moderately cross-linked polyethylene.

    PubMed

    Abdelgaied, Abdellatif; Brockett, Claire L; Liu, Feng; Jennings, Louise M; Fisher, John; Jin, Zhongmin

    2013-01-01

    Polyethylene wear is a great concern in total joint replacement. It is now considered a major limiting factor to the long life of such prostheses. Cross-linking has been introduced to reduce the wear of ultra-high-molecular-weight polyethylene (UHMWPE). Computational models have been used extensively for wear prediction and optimization of artificial knee designs. However, in order to be independent and have general applicability and predictability, computational wear models should be based on inputs from independent experimentally determined wear parameters (wear factors or wear coefficients). The objective of this study was to investigate moderately cross-linked UHMWPE, using a multidirectional pin-on-plate wear test machine, under a wide range of applied nominal contact pressure (from 1 to 11 MPa) and under five different kinematic inputs, varying from a purely linear track to a maximum rotation of +/- 55 degrees. A computational model, based on a direct simulation of the multidirectional pin-on-plate wear tester, was developed to quantify the degree of cross-shear (CS) of the polyethylene pins articulating against the metallic plates. The moderately cross-linked UHMWPE showed wear factors less than half of that reported in the literature for, the conventional UHMWPE, under the same loading and kinematic inputs. In addition, under high applied nominal contact stress, the moderately crosslinked UHMWPE wear showed lower dependence on the degree of CS compared to that under low applied nominal contact stress. The calculated wear coefficients were found to be independent of the applied nominal contact stress, in contrast to the wear factors that were shown to be highly pressure dependent. This study provided independent wear data for inputs into computational models for moderately cross-linked polyethylene and supported the application of wear coefficient-based computational wear models.

  16. How do gait frequency and serum-replacement interval affect polyethylene wear in knee-wear simulator tests?

    PubMed

    Reinders, Jörn; Sonntag, Robert; Kretzer, Jan Philippe

    2014-11-01

    Polyethylene wear (PE) is known to be a limiting factor in total joint replacements. However, a standardized wear test (e.g. ISO standard) can only replicate the complex in vivo loading condition in a simplified form. In this study, two different parameters were analyzed: (a) Bovine serum, as a substitute for synovial fluid, is typically replaced every 500,000 cycles. However, a continuous regeneration takes place in vivo. How does serum-replacement interval affect the wear rate of total knee replacements? (b) Patients with an artificial joint show reduced gait frequencies compared to standardized testing. What is the influence of a reduced frequency? Three knee wear tests were run: (a) reference test (ISO), (b) testing with a shortened lubricant replacement interval, (c) testing with reduced frequency. The wear behavior was determined based on gravimetric measurements and wear particle analysis. The results showed that the reduced test frequency only had a small effect on wear behavior. Testing with 1 Hz frequency is therefore a valid method for wear testing. However, testing with a shortened replacement interval nearly doubled the wear rate. Wear particle analysis revealed only small differences in wear particle size between the different tests. Wear particles were not linearly released within one replacement interval. The ISO standard should be revised to address the marked effects of lubricant replacement interval on wear rate.

  17. Correction of radiographic measurements of acetabular cup wear for variations in pelvis orientation.

    PubMed

    Derbyshire, Brian

    2018-03-01

    Radiographic measurement of two-dimensional acetabular cup wear is usually carried out on a series of follow-up radiographs of the patient's pelvis. Since the orientation of the pelvis might not be consistent at every X-ray examination, the resulting change in view of the wear plane introduces error into the linear wear measurement. This effect is amplified on some designs of cup in which the centre of the socket is several millimetres below the centre of the cup or circular wire marker. This study describes the formulation of a mathematical method to correct radiographic wear measurements for changes in pelvis orientation. A mathematical simulation of changes in cup orientation and wear vectors caused by pelvic tilt was used to confirm that the formulae corrected the wear exactly if the radiographic plane of the reference radiograph was parallel to the true plane of wear. An error analysis showed that even when the true wear plane was not parallel to the reference radiographic plane, the formulae could still provide a useful correction. A published correction formula was found to be ineffective.

  18. Correction of radiographic measurements of acetabular cup wear for variations in pelvis orientation

    PubMed Central

    Derbyshire, Brian

    2018-01-01

    Radiographic measurement of two-dimensional acetabular cup wear is usually carried out on a series of follow-up radiographs of the patient’s pelvis. Since the orientation of the pelvis might not be consistent at every X-ray examination, the resulting change in view of the wear plane introduces error into the linear wear measurement. This effect is amplified on some designs of cup in which the centre of the socket is several millimetres below the centre of the cup or circular wire marker. This study describes the formulation of a mathematical method to correct radiographic wear measurements for changes in pelvis orientation. A mathematical simulation of changes in cup orientation and wear vectors caused by pelvic tilt was used to confirm that the formulae corrected the wear exactly if the radiographic plane of the reference radiograph was parallel to the true plane of wear. An error analysis showed that even when the true wear plane was not parallel to the reference radiographic plane, the formulae could still provide a useful correction. A published correction formula was found to be ineffective. PMID:29473454

  19. Influence of the antagonist material on the wear of different composites using two different wear simulation methods.

    PubMed

    Heintze, S D; Zellweger, G; Cavalleri, A; Ferracane, J

    2006-02-01

    The aim of the study was to evaluate two ceramic materials as possible substitutes for enamel using two wear simulation methods, and to compare both methods with regard to the wear results for different materials. Flat specimens (OHSU n=6, Ivoclar n=8) of one compomer and three composite materials (Dyract AP, Tetric Ceram, Z250, experimental composite) were fabricated and subjected to wear using two different wear testing methods and two pressable ceramic materials as stylus (Empress, experimental ceramic). For the OHSU method, enamel styli of the same dimensions as the ceramic stylus were fabricated additionally. Both wear testing methods differ with regard to loading force, lateral movement of stylus, stylus dimension, number of cycles, thermocycling and abrasive medium. In the OHSU method, the wear facets (mean vertical loss) were measured using a contact profilometer, while in the Ivoclar method (maximal vertical loss) a laser scanner was used for this purpose. Additionally, the vertical loss of the ceramic stylus was quantified for the Ivoclar method. The results obtained from each method were compared by ANOVA and Tukey's test (p<0.05). To compare both wear methods, the log-transformed data were used to establish relative ranks between material/stylus combinations and assessed by applying the Pearson correlation coefficient. The experimental ceramic material generated significantly less wear in Tetric Ceram and Z250 specimens compared to the Empress stylus in the Ivoclar method, whereas with the OHSU method, no difference between the two ceramic antagonists was found with regard to abrasion or attrition. The wear generated by the enamel stylus was not statistically different from that generated by the other two ceramic materials in the OHSU method. With the Ivoclar method, wear of the ceramic stylus was only statistically different when in contact with Tetric Ceram. There was a close correlation between the attrition wear of the OHSU and the wear of the Ivoclar method (Pearson coefficient 0.83, p=0.01). Pressable ceramic materials can be used as a substitute for enamel in wear testing machines. However, material ranking may be affected by the type of ceramic material chosen. The attrition wear of the OHSU method was comparable with the wear generated with the Ivoclar method.

  20. A study on die wear model of warm and hot forgings

    NASA Astrophysics Data System (ADS)

    Kang, J. H.; Park, I. W.; Jae, J. S.; Kang, S. S.

    1998-05-01

    Factors influencing service lives of tools in warm and hot forging processes are wear, mechanical fatigue, plastic deformation and thermal fatigue, etc. Wear is the predominant factor for tool failure among these. To predict tool life by wear, Archard's model where hardness is considered as constant or function of temperature is generally applied. Usually hardness of die is a function of not only temperature but operating time of die. To consider softening of die by repeated operation it is necessary to express hardness of die by a function of temperature and time. In this study wear coefficients were measured for various temperatures and heat treatment for H13 tool steel. Also by experiment of reheating of die, die softening curves were obtained. From experimental results, relationships between tempering parameters and hardness were established to investigate effects of hardness decrease by the effect of temperatures and time. Finally modified Archard's wear model in which hardness is considered to be a function of main tempering curve was proposed. And finite element analyses were conducted by adopting suggested wear model. By comparisons of simulations and real profiles of worn die, proposed wear model was verified.

  1. Enamel Microcracks Induced by Simulated Occlusal Wear in Mature, Immature, and Deciduous Teeth

    PubMed Central

    Ijbara, Manhal; Tabata, Makoto J.; Wada, Junichiro; Miyashin, Michiyo

    2018-01-01

    Enamel wear, which is inevitable due to the process of mastication, is a process in which the microcracking of enamel occurs due to the surface contacting very small hard particles. When these particles slide on enamel, a combined process of microcutting and microcracking in the surface and subsurface of the enamel takes place. The aim of this study was to detect microscopic differences in the microcrack behavior by subjecting enamel specimens derived from different age groups (immature open-apex premolars, mature closed-apex premolars, and deciduous molars) to cycles of simulated impact and sliding wear testing under controlled conditions. Our findings indicated that the characteristics of the microcracks, including the length, depth, count, orientation, and relation to microstructures differed among the study groups. The differences between the surface and subsurface microcrack characteristics were most notable in the enamel of deciduous molars followed by immature premolars and mature premolars whereby deciduous enamel suffered numerous, extensive, and branched microcracks. Within the limitations of this study, it was concluded that enamel surface and subsurface microcracks characteristics are dependent on the posteruptive age with deciduous enamel being the least resistant to wear based on the microcrack behavior as compared to permanent enamel. PMID:29850534

  2. Applicability of out-of-pile fretting wear tests to in-reactor fretting wear-induced failure time prediction

    NASA Astrophysics Data System (ADS)

    Kim, Kyu-Tae

    2013-02-01

    In order to investigate whether or not the grid-to-rod fretting wear-induced fuel failure will occur for newly developed spacer grid spring designs for the fuel lifetime, out-of-pile fretting wear tests with one or two fuel assemblies are to be performed. In this study, the out-of-pile fretting wear tests were performed in order to compare the potential for wear-induced fuel failure in two newly-developed, Korean PWR spacer grid designs. Lasting 20 days, the tests simulated maximum grid-to-rod gap conditions and the worst flow induced vibration effects that might take place over the fuel life time. The fuel rod perforation times calculated from the out-of-pile tests are greater than 1933 days for 2 μm oxidized fuel rods with a 100 μm grid-to-rod gap, whereas those estimated from in-reactor fretting wear failure database may be about in the range of between 60 and 100 days. This large discrepancy in fuel rod perforation may occur due to irradiation-induced cladding oxide microstructure changes on the one hand and a temperature gradient-induced hydrogen content profile across the cladding metal region on the other hand, which may accelerate brittleness in the grid-contacting cladding oxide and metal regions during the reactor operation. A three-phase grid-to-rod fretting wear model is proposed to simulate in-reactor fretting wear progress into the cladding, considering the microstructure changes of the cladding oxide and the hydrogen content profile across the cladding metal region combined with the temperature gradient. The out-of-pile tests cannot be directly applicable to the prediction of in-reactor fretting wear-induced cladding perforations but they can be used only for evaluating a relative wear resistance of one grid design against the other grid design.

  3. Numerical study of the influence of the thickness and roughness of TiN coatings on their wear in scratch testing

    NASA Astrophysics Data System (ADS)

    Eremina, G. M.; Smolin, A. Yu.

    2017-12-01

    One of the mostly used and complicated surgical operations on large human joints is total hip replacement. An endoprosthesis is chosen individually for each person on the basis of his anatomical features and physical activity. However, such an important factor affecting the durability of an endoprosthesis as wear in the head-acetabular cup friction pair is still poorly understood, and it is taken into account only qualitatively. The determining role in wear belongs to the structure of the surface layers and coatings of the friction pair. The mechanical and structural characteristics of the coating largely depend on the method of its application. In this paper, to study the tribological characteristics of the coating material of the friction pair, we use computer simulation of scratch testing. The simulations are performed with the application of the method of movable cellular automata. The model specimens correspond to real coatings manufactured under different treatment conditions (deposition temperature and time). The analysis of the simulation results allows one to choose the optimal regime corresponding to the maximum hardness of coatings or adhesive strength.

  4. Influence of filler loading on the two-body wear of a dental composite.

    PubMed

    Hu, X; Marquis, P M; Shortall, A C

    2003-07-01

    The purpose of the study was to explore the fundamental wear behaviour of a dental composite with different filler loadings under two-body wear conditions. The parent resin and filler components were mixed according to different weight ratios to produce experimental composites with filler loadings ranging from 20 to 87.5% by weight. A two-body wear test was conducted on the experimental composites using a wear-testing machine. The machine was designed to simulate the impact of the direct cyclic masticatory loading that occurs in the occlusal contact area in vivo. The results showed that there was little increase in the rate of wear with filler loadings below 60 wt%, but a sharp increase between 80 and 87.5 wt% in filler loading. Wide striations and bulk loss of material were apparent on the wear surfaces at higher filler loadings. Coefficients of friction increased with filler loading and followed the increase in rate of wear loss closely. It was concluded that, under two-body wear conditions, addition of high levels of filler particles into the resin matrix could reduce the wear resistance of dental composites. This finding may help when designing future dental composites for use in particular clinical settings.

  5. Abrasion and deformed layer formation of manganese-zinc ferrite in sliding contact with lapping tapes

    NASA Technical Reports Server (NTRS)

    Miyoshi, K.; Buckley, D. H.; Tanaka, K.

    1986-01-01

    Wear experiments were conducted using replication electron microscopy and reflection electron diffraction to study abrasion and the deformed layers produced in single-crystal Mn-Zn ferrite simulated heads during contact with lapping tapes. The crystaline state of the head is changed drastically during the abrasion process. Crystalline states ranging from nearly amorphous to highly textured polycrystalline can be produced on the wear surface of a single-crystal Mn-Zn ferrite head. The total thickness of the deformed layer was approximately 0.8 microns. This thickness increased as the load and abrasive grit size increased. The anisotropic wear of the ferrite was found to be inversely proportional to the hardness of the wear surface. The wear was lower in the order 211 111 10 0110. The wear of the ferrite increased markedly with an increase in sliding velocity and abrasive grit size.

  6. Evaluation of a new methodology to simulate damage and wear of polyethylene hip replacements subjected to edge loading in hip simulator testing.

    PubMed

    Partridge, Susan; Tipper, Joanne L; Al-Hajjar, Mazen; Isaac, Graham H; Fisher, John; Williams, Sophie

    2018-05-01

    Wear and fatigue of polyethylene acetabular cups have been reported to play a role in the failure of total hip replacements. Hip simulator testing under a wide range of clinically relevant loading conditions is important. Edge loading of hip replacements can occur following impingement under extreme activities and can also occur during normal gait, where there is an offset deficiency and/or joint laxity. This study evaluated a hip simulator method that assessed wear and damage in polyethylene acetabular liners that were subjected to edge loading. The liners tested to evaluate the method were a currently manufactured crosslinked polyethylene acetabular liner and an aged conventional polyethylene acetabular liner. The acetabular liners were tested for 5 million standard walking cycles and following this 5 million walking cycles with edge loading. Edge loading conditions represented a separation of the centers of rotation of the femoral head and the acetabular liner during the swing phase, leading to loading of the liner rim on heel strike. Rim damage and cracking was observed in the aged conventional polyethylene liner. Steady-state wear rates assessed gravimetrically were lower under edge loading compared to standard loading. This study supports previous clinical findings that edge loading may cause rim cracking in liners, where component positioning is suboptimal or where material degradation is present. The simulation method developed has the potential to be used in the future to test the effect of aging and different levels of severity of edge loading on a range of cross-linked polyethylene materials. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 1456-1462, 2018. © 2017 Wiley Periodicals, Inc.

  7. A rolling-gliding wear simulator for the investigation of tribological material pairings for application in total knee arthroplasty.

    PubMed

    Richter, Berna I; Ostermeier, Sven; Turger, Anke; Denkena, Berend; Hurschler, Christof

    2010-06-15

    Material wear testing is an important technique in the development and evaluation of materials for use in implant for total knee arthroplasty. Since a knee joint induces a complex rolling-gliding movement, standardised material wear testing devices such as Pin-on-Disc or Ring-on-Disc testers are suitable to only a limited extent because they generate pure gliding motion only. A rolling-gliding wear simulator was thus designed, constructed and implemented, which simulates and reproduces the rolling-gliding movement and loading of the knee joint on specimens of simplified geometry. The technical concept was to run a base-plate, representing the tibia plateau, against a pivoted cylindrical counter-body, representing one femur condyle under an axial load. A rolling movement occurs as a result of the friction and pure gliding is induced by limiting the rotation of the cylindrical counter-body. The set up also enables simplified specimens handling and removal for gravimetrical wear measurements. Long-term wear tests and gravimetrical wear measurements were carried out on the well known material pairings: cobalt chrome-polyethylene, ceramic-polyethylene and ceramic-ceramic, over three million motion cycles to allow material comparisons to be made. The observed differences in wear rates between cobalt-chrome on polyethylene and ceramic on polyethylene pairings were similar to the differences of published data for existing material-pairings. Test results on ceramic-ceramic pairings of different frontal-plane geometry and surface roughness displayed low wear rates and no fracture failures. The presented set up is able to simulate the rolling-gliding movement of the knee joint, is easy to use, and requires a minimum of user intervention or monitoring. It is suitable for long-term testing, and therefore a useful tool for the investigation of new and promising materials which are of interest for application in knee joint replacement implants.

  8. A rolling-gliding wear simulator for the investigation of tribological material pairings for application in total knee arthroplasty

    PubMed Central

    2010-01-01

    Background Material wear testing is an important technique in the development and evaluation of materials for use in implant for total knee arthroplasty. Since a knee joint induces a complex rolling-gliding movement, standardised material wear testing devices such as Pin-on-Disc or Ring-on-Disc testers are suitable to only a limited extent because they generate pure gliding motion only. Methods A rolling-gliding wear simulator was thus designed, constructed and implemented, which simulates and reproduces the rolling-gliding movement and loading of the knee joint on specimens of simplified geometry. The technical concept was to run a base-plate, representing the tibia plateau, against a pivoted cylindrical counter-body, representing one femur condyle under an axial load. A rolling movement occurs as a result of the friction and pure gliding is induced by limiting the rotation of the cylindrical counter-body. The set up also enables simplified specimens handling and removal for gravimetrical wear measurements. Long-term wear tests and gravimetrical wear measurements were carried out on the well known material pairings: cobalt chrome-polyethylene, ceramic-polyethylene and ceramic-ceramic, over three million motion cycles to allow material comparisons to be made. Results The observed differences in wear rates between cobalt-chrome on polyethylene and ceramic on polyethylene pairings were similar to the differences of published data for existing material-pairings. Test results on ceramic-ceramic pairings of different frontal-plane geometry and surface roughness displayed low wear rates and no fracture failures. Conclusions The presented set up is able to simulate the rolling-gliding movement of the knee joint, is easy to use, and requires a minimum of user intervention or monitoring. It is suitable for long-term testing, and therefore a useful tool for the investigation of new and promising materials which are of interest for application in knee joint replacement implants. PMID:20550669

  9. Friction-Testing Machine

    NASA Technical Reports Server (NTRS)

    Benz, F. J.; Dixon, D. S.; Shaw, R. C.

    1986-01-01

    Testing machine evaluates wear and ignition characteristics of materials in rubbing contact. Offers advantages over other laboratory methods of measuring wear because it simulates operating conditions under which material will actually be used. Machine used to determine wear characteristics, rank and select materials for service with such active oxidizers as oxygen, halogens, and oxides of nitrogen, measure wear characteristics, and determine coefficients of friction.

  10. Simulator trials to determine the wear of the combination aluminium oxide ceramic-carbon fibre reinforced plastic (CFRP) used as an insert in a hip socket.

    PubMed

    Scheller, G; Schwarz, M; Früh, H J; Jani, L

    1999-01-01

    Hip simulator trials were conducted to determine the initial wear between alumina femoral heads and carbon fibre reinforced plastic (CFRP, CAPROMAN) insert in a titanium socket. A force of 2500 N and a frequency of 0.857 H were applied. Using surface and sphericity measurement techniques, the amount of wear was determined. After 500,000 cycles, the centre of the head had moved by 10 microm into the insert, and the average radius increased by 2 microm. After 1 million cycles, the additional changes were less than 1 microm. Based on an examination of retrieved implants (wear rate: 6.1 microm/year) and based on the simulator results, the combination alumina-CFRP inserts could be approved for total hip replacement.

  11. Effect of progressive wear on the contact mechanics of hip replacements--does the realistic surface profile matter?

    PubMed

    Wang, Ling; Yang, Wenjian; Peng, Xifeng; Li, Dichen; Dong, Shuangpeng; Zhang, Shu; Zhu, Jinyu; Jin, Zhongmin

    2015-04-13

    The contact mechanics of artificial metal-on-polyethylene hip joints are believed to affect the lubrication, wear and friction of the articulating surfaces and may lead to the joint loosening. Finite element analysis has been widely used for contact mechanics studies and good agreements have been achieved with current experimental data; however, most studies were carried out with idealist spherical geometries of the hip prostheses rather than the realistic worn surfaces, either for simplification reason or lacking of worn surface profile. In this study, the worn surfaces of the samples from various stages of hip simulator testing (0 to 5 million cycles) were reconstructed as solid models and were applied in the contact mechanics study. The simulator testing results suggested that the center of the head has various departure value from that of the cup and the value of the departure varies with progressively increased wear. This finding was adopted into the finite element study for better evaluation accuracy. Results indicated that the realistic model provided different evaluation from that of the ideal spherical model. Moreover, with the progressively increased wear, large increase of the contact pressure (from 12 to 31 MPa) was predicted on the articulating surface, and the predicted maximum von Mises stress was increased from 7.47 to 13.26 MPa, indicating the marked effect of the worn surface profiles on the contact mechanics of the joint. This study seeks to emphasize the importance of realistic worn surface profile of the acetabular cup especially following large wear volume. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Effect of size and dimensional tolerance of reverse total shoulder arthroplasty on wear: An in-silico study.

    PubMed

    Mattei, Lorenza; Di Puccio, Francesca; Joyce, Thomas J; Ciulli, Enrico

    2016-08-01

    Although huge research efforts have been devoted to wear analysis of ultra-high molecular weight polyethylene (UHMWPE) in hip and knee implants, shoulder prostheses have been studied only marginally. Recently, the authors presented a numerical wear model of reverse total shoulder arthroplasties (RTSAs), and its application for estimating the wear coefficient k from experimental data according to different wear laws. In this study, such model and k expressions are exploited to investigate the sensitivity of UHMWPE wear to implant size and dimensional tolerance. A set of 10 different geometries was analysed, considering nominal diameters in the range 36-42mm, available on the market, and a cup dimensional tolerance of +0.2, -0.0mm (resulting in a diametrical clearance ranging between 0.04-0.24mm), estimated from measurements on RTSAs. Since the most reliable wear law and wear coefficient k for UHMWPE are still controversial in the literature, both the Archard law (AR) and the wear law of UHMWPE (PE), as well as four different k expressions were considered, carrying out a total of 40 simulations. Results showed that the wear volume increases with the implant size and decreases with the dimensional tolerance for both the wear laws. Interestingly, different trends were obtained for the maximum wear depth vs. clearance: the best performing implants should have a high conformity according to the AR law but low conformity for the PE law. However, according to both laws, wear is highly affected by both implant size and dimensional tolerance, although it is much more sensitive to the latter, with up to a twofold variation of wear predicted. Indeed, dimensional tolerance directly alters the clearance, and therefore the lubrication and contact pressure distribution in the implant. Rather surprisingly the role of dimensional tolerance has been completely disregarded in the literature, as well as in the standards. Furthermore, this study notes some important issues for future work, such as the validation of wear laws and predictive wear models and the sensitivity of k to implant geometry. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Design study of shaft face seal with self-acting lift augmentation. 5: Performance in simulated gas turbine engine operation

    NASA Technical Reports Server (NTRS)

    Ludwig, L. P.; Johnson, R. L.

    1971-01-01

    The feasibility and the noncontact operation of the self-acting seal was demonstrated over a range of simulated gas turbine engine conditions from 200 to 500 ft/sec sliding speed. Sealed pressure differentials were 50 to 300 psi and sealed temperatures were 150 to 1200 F. Low leakage (about 1/10 that of conventional labyrinth seals) was exhibited in two endurance runs (200 and 338 hr) at 400 ft/sec, 200 psi and 1000 F (gas temperature). For these endurance runs, the self-acting pad wear was less than 3.8 micrometers (0.00015 in.); this low wear was attributed to the noncontact operation of the primary seal. Operating problems identified were fretting wear of the secondary seal and erosion of the primary seal by hard particles.

  14. Astronaut Bonnie Dunbar wearing extravehicular mobility unit

    NASA Technical Reports Server (NTRS)

    1985-01-01

    Astronaut Bonnie J. Dunbar, wearing an extravehicular mobility unit (EMU), is about to be submerged in the weightless environment training facility (WETF) to simulate a contingency extravehicular activity (EVA) for STS 61-A. In this portrait view, Dunbar is not wearing a helmet.

  15. Flank wears Simulation by using back propagation neural network when cutting hardened H-13 steel in CNC End Milling

    NASA Astrophysics Data System (ADS)

    Hazza, Muataz Hazza F. Al; Adesta, Erry Y. T.; Riza, Muhammad

    2013-12-01

    High speed milling has many advantages such as higher removal rate and high productivity. However, higher cutting speed increase the flank wear rate and thus reducing the cutting tool life. Therefore estimating and predicting the flank wear length in early stages reduces the risk of unaccepted tooling cost. This research presents a neural network model for predicting and simulating the flank wear in the CNC end milling process. A set of sparse experimental data for finish end milling on AISI H13 at hardness of 48 HRC have been conducted to measure the flank wear length. Then the measured data have been used to train the developed neural network model. Artificial neural network (ANN) was applied to predict the flank wear length. The neural network contains twenty hidden layer with feed forward back propagation hierarchical. The neural network has been designed with MATLAB Neural Network Toolbox. The results show a high correlation between the predicted and the observed flank wear which indicates the validity of the models.

  16. Astronaut James Buchli wearing extravehicular mobility unit

    NASA Technical Reports Server (NTRS)

    1985-01-01

    Astronaut James F. Buchli, wearing an extravehicular mobility unit (EMU), is about to be submerged in the weightless environment training facility (WETF) to simulate a contingency extravehicular activity (EVA) for STS 61-A. In this portrait view, Buchli is wearing a communications carrier assembly (CCA).

  17. Molecular dynamics simulation investigations of atomic-scale wear

    NASA Astrophysics Data System (ADS)

    Shao, Yuchong; Falk, Michael

    2013-03-01

    Frictional running-in and material transfer in wear take place at the micro- and nano-scale but the fundamental physics remain poorly understood. Here we intend to investigate wear and running-in phenomena in silicon based materials, which are widely utilized in micro/nano electromechanical systems(MEMS/NEMS). We use an atomic force microscopy (AFM) model composed of a crystalline silicon tip and substrate coated with native oxide layers. Molecular dynamics simulation has been performed over a range of temperatures, external loads and slip rates. Results show that adhesive wear takes place across the interface in an atom-by-atom fashion which remodels the tip leading to a final steady state. We quantify the rate of material transfer as a function of the coverage of non-bridging oxygen (NBO) atoms, which has a pronounced change of the system's tribological and wear behaviors. A constitutive rate and state model is proposed to predict the evolution of frictional strength and wear. This work is supported by the National Science Foundation under Award No. 0926111.

  18. Laser surface modification of Ti--6Al--4V: wear and corrosion characterization in simulated biofluid.

    PubMed

    Singh, Raghuvir; Kurella, A; Dahotre, Narendra B

    2006-07-01

    Laser surface melting (LSM) of Ti-6Al-4V is performed in argon to improve its properties, such as microstructure, corrosion, and wear for biomedical applications. Corrosion behavior is investigated by conducting electrochemical polarization experiments in simulated body fluid (Ringer's solution) at 37 C. Wear properties are evaluated in Ringer's solution using pin-on-disc apparatus at a slow speed. Untreated Ti-6Al-4V contains alpha+beta phase. After laser surface melting, it transforms to acicular alpha embedded in the prior beta matrix. Grain growth in the range of 65-89 microm with increase in laser power from 800 to 1500 W due to increase in associated temperature is observed. The hardness of as-laserprocessed Ti-6Al-4V alloy is more (275-297 HV) than that of the untreated alloy (254 HV). Passivation currents are significantly reduced to < 4.3 microA/cm2 after laser treatment compared to untreated Ti-6Al-4V (approximately 12 microA/cm2). The wear resistance of laser-treated Ti-6Al-4V in simulated body fluid is enhanced compared to that of the untreated one. It is the highest for the one that is processed at a laser power of 800 W. Typical micro-cutting features of abrasive wear is the prominent mechanism of wear in both untreated and as-laser-treated Ti-6Al-4V. Fragmentation of wear debris assisted by microcracking was responsible for mass loss during the wear of untreated Ti-6Al-4V in Ringer's solution.

  19. Numerical prediction of rail roughness growth on tangent railway tracks

    NASA Astrophysics Data System (ADS)

    Nielsen, J. C. O.

    2003-10-01

    Growth of railhead roughness (irregularities, waviness) is predicted through numerical simulation of dynamic train-track interaction on tangent track. The hypothesis is that wear is caused by longitudinal slip due to driven wheelsets, and that wear is proportional to the longitudinal frictional power in the contact patch. Emanating from an initial roughness spectrum corresponding to a new or a recent ground rail, an initial roughness profile is determined. Wheel-rail contact forces, creepages and wear for one wheelset passage are calculated in relation to location along a discretely supported track model. The calculated wear is scaled by a chosen number of wheelset passages, and is then added to the initial roughness profile. Field observations of rail corrugation on a Dutch track are used to validate the simulation model. Results from the simulations predict a large roughness growth rate for wavelengths around 30-40 mm. The large growth in this wavelength interval is explained by a low track receptance near the sleepers around the pinned-pinned resonance frequency, in combination with a large number of driven passenger wheelset passages at uniform speed. The agreement between simulations and field measurements is good with respect to dominating roughness wavelength and annual wear rate. Remedies for reducing roughness growth are discussed.

  20. Impact wear behavior of human tooth enamel under simulated chewing conditions.

    PubMed

    Zheng, Jing; Zeng, Yangyang; Wen, Jian; Zheng, Liang; Zhou, Zhongrong

    2016-09-01

    Previous studies mostly focused on the sliding wear behavior of human teeth, and little effort has been made so far to study the impact wear of human teeth. The objective of this study was to investigate the impact wear process and mechanism of human tooth enamel and the influence of water content within enamel. In this paper, the impact wear behaviors of fresh and dried human tooth enamel against SiC ceramic have been investigated using a specially designed impact test machine. Tests lasting up to 5×10(3), 5×10(4), 2.5×10(5), 5.5×10(5), 8×10(5) and 1×10(6) cycles were conducted, respectively. Results showed that for the fresh enamel, the surface damage was dominated by plastic deformation at the early stage of impact wear. Iridescent rings appeared around the impact mark as a result of the accumulation and spread of plastic deformation. As the impact wear progressed, delamination occurred on the surface of enamel, and thus the iridescent rings gradually disappeared. Wear loss increased rapidly with the increase of impact cycles. When a wear particle layer was formed on the enamel surface, the wear rate decreased. It was found that the surface hardness of enamel increased with the impact cycles, and no cracks appeared on the cross section of wear scar. Compared with the fresh enamel, the fracture toughness of dried enamel decreased, and thus there were microcracks appearing on the cross section of wear scar. More obvious delamination occurred on the worn surface of dried enamel, and no iridescent rings were observed. The wear loss of dried enamel was higher than that of fresh enamel. In summary, the impact wear behavior of sound human tooth enamel was metal-like to some degree, and no subsurface cracking occurred. The water content within enamel could increase its fracture toughness and protect the surface from impact wear. The wear mechanism of human tooth enamel is determined by its microstructure. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Microtomography evaluation of dental tissue wear surface induced by in vitro simulated chewing cycles on human and composite teeth.

    PubMed

    Bedini, Rossella; Pecci, Raffaella; Notarangelo, Gianluca; Zuppante, Francesca; Persico, Salvatore; Di Carlo, Fabio

    2012-01-01

    In this study a 3D microtomography display of tooth surfaces after in vitro dental wear tests has been obtained. Natural teeth have been compared with prosthetic teeth, manufactured by three different polyceramic composite materials. The prosthetic dental element samples, similar to molars, have been placed in opposition to human teeth extracted by paradontology diseases. After microtomography analysis, samples have been subjected to in vitro fatigue test cycles by servo-hydraulic mechanical testing machine. After the fatigue test, each sample has been subjected again to microtomography analysis to obtain volumetric value changes and dental wear surface images. Wear surface images were obtained by 3D reconstruction software and volumetric value changes were measured by CT analyser software. The aim of this work has been to show the potential of microtomography technique to display very clear and reliable wear surface images. Microtomography analysis methods to evaluate volumetric value changes have been used to quantify dental tissue and composite material wear.

  2. Three-body wear of resin denture teeth with and without nanofillers.

    PubMed

    Stober, Thomas; Henninger, Moritz; Schmitter, Marc; Pritsch, Maria; Rammelsberg, Peter

    2010-02-01

    The wear behavior of newly developed denture teeth with nanofillers may be different from teeth with other chemical formulations. The purpose of this study was to examine the 3-body wear resistance of 11 different commercially available resin denture teeth. The materials tested were conventional (SR Orthotyp PE, Orthognath) and cross-linked acrylic resin teeth without inorganic fillers (Premium 8, SR Postaris DCL, Trubyte Portrait, Artiplus), composite resin teeth with inorganic fillers (SR Orthosit PE, Vitapan), and composite resin teeth (experimental materials) with inorganic nanofillers (NC Veracia Posterior, e-Ha, Mondial). Human enamel and a ceramic denture tooth (Lumin Vacuum) were used as reference materials. The 3-body wear test was performed in a wear machine developed by the Academic Center for Dentistry Amsterdam (ACTA), with millet suspension acting as an abrasive medium (n=10, test load: 15 N, slip rate: 20%, number of cycles: 100,000). Wear was determined with the aid of a profilometer. Data were analyzed with the Kruskal-Wallis test and Mann-Whitney U test using the closed testing approach (significance level for familywise error rate, alpha=.05). None of the acrylic and composite resin materials tested in this study demonstrated the 3-body wear resistance of ceramic teeth or human enamel. Teeth with inorganic fillers demonstrated significantly lower wear values than conventional or cross-linked acrylic resin teeth without fillers. Composite resin teeth with traditional fillers showed significantly lower wear than composite resin teeth with nanofillers. Denture teeth with and without inorganic fillers differed significantly with regard to the degree of wear generated in the ACTA wear simulator. The incorporation of nanofillers did not improve the wear resistance compared to teeth with traditional fillers.

  3. "Kicking Up Some Dust": An Experimental Investigation Relating Lunar Dust Erosive Wear to Solar Power Loss

    NASA Technical Reports Server (NTRS)

    Mpagazehe, Jeremiah N.; Street, Kenneth W., Jr.; Delgado, Irebert R.; Higgs, C. Fred, III

    2013-01-01

    The exhaust from retrograde rockets fired by spacecraft landing on the Moon can accelerate lunar dust particles to high velocities. Information obtained from NASA's Apollo 12 mission confirmed that these high-speed dust particles can erode nearby structures. This erosive wear damage can affect the performance of optical components such as solar concentrators. Solar concentrators are objects which collect sunlight over large areas and focus the light into smaller areas for purposes such as heating and energy production. In this work, laboratory-scale solar concentrators were constructed and subjected to erosive wear by the JSC-1AF lunar dust simulant. The concentrators were focused on a photovoltaic cell and the degradation in electrical power due to the erosive wear was measured. It was observed that even moderate exposure to erosive wear from lunar dust simulant resulted in a 40 percent reduction in power production from the solar concentrators.

  4. Heart rate and pulmonary function while wearing the launch-entry crew escape suit (LES) during + Gx acceleration and simulated Shuttle launch

    NASA Technical Reports Server (NTRS)

    Krutz, Robert W., Jr.; Bagian, James P.; Burton, Russell R.; Meeker, Larry J.

    1990-01-01

    Space shuttle crewmembers have been equipped with a launch-entry crew escape system (LES) since the Challenger accident in 1986. Some crewmembers, wearing the new pressure suit, have reported breathing difficulties and increased effort to achieve the desired range of motion. This study was conducted to quantify the reported increased physical workloads and breathing difficulty associated with wearing the LES. Both veteran astronauts and centrifuge panel members were exposed to various + Gx profiles (including simulated shuttle launch) + Gx on the USAF School of Aerospace Medicine (USAFSAM) human-use centrifuge. Maximum heart rate data showed no increased workload associated with arm and head movement in the LES when compared to the flight suit/helmet ensemble (LEH). However, the LES did impose a significant increase in breathing difficulty beginning at +2.5 Gx which was demonstrated by a decrease in forced vital capacity and subjected questionnaries.

  5. Simulation of automotive wrist pin joint and tribological studies of tin coated Al-Si alloy, metal matrix composites and nitrogen ceramics under mixed lubrication

    NASA Astrophysics Data System (ADS)

    Wang, Qian

    Development of automotive engines with high power output demands the application of high strength materials with good tribological properties. Metal matrix composites (MMC's) and some nitrogen ceramics are of interest to replace some conventional materials in the piston/pin/connecting rod design. A simulation study has been developed to explore the possibility to employ MMC's as bearing materials and ceramics as journal materials, and to investigate the related wear mechanisms and the possible journal bearing failure mechanisms. Conventional tin coated Al-Si alloy (Al-Si/Sn) have been studied for the base line information. A mixed lubrication model for journal bearing with a soft coating has been developed and applied to the contact and temperature analysis of the Al-Si/Sn bearing. Experimental studies were performed to reveal the bearing friction and wear behavior. Tin coating exhibited great a advantage in friction reduction, however, it suffered significant wear through pitting and debonding. When the tin wore out, the Al-Si/steel contact experienced higher friction. A cast and P/M MMC's in the lubricated contact with case hardened steel and ceramic journals were studied experimentally. Without sufficient material removal in the conformal contact situation, MMC bearings in the MMC/steel pairs gained weight due to iron transfer and surface tribochemical reactions with the lubricant additives and contact failure occurred. However, the MMC/ceramic contacts demonstrated promising tribological behavior with low friction and high wear resistance, and should be considered for new journal bearing design. Ceramics are wear resistant. Ceramic surface roughness is very crucial when the journals are in contact with the tin coated bearings. In contact with MMC bearings, ceramic surface quality and fracture toughness seem to play some important roles in affecting the friction coefficient. The wear of silicon nitride and beta sialon (A) journals is pitting due to grain boundary fracture and grain pull-out.

  6. Wear resistance of poly(2-methacryloyloxyethyl phosphorylcholine)-grafted carbon fiber reinforced poly(ether ether ketone) liners against metal and ceramic femoral heads.

    PubMed

    Yamane, Shihori; Kyomoto, Masayuki; Moro, Toru; Hashimoto, Masami; Takatori, Yoshio; Tanaka, Sakae; Ishihara, Kazuhiko

    2018-04-01

    Younger, active patients who undergo total hip arthroplasty (THA) have increasing needs for wider range of motion and improved stability of the joint. Therefore, bearing materials having not only higher wear resistance but also mechanical strength are required. Carbon fiber-reinforced poly(ether ether ketone) (CFR-PEEK) is known as a super engineering plastic that has great mechanical strength. In this study, we focused on poly(2-methacryloyloxyethyl phosphorylcholine) (PMPC)-grafted CFR-PEEK and investigated the effects of PMPC grafting and the femoral heads materials on the wear properties of CFR-PEEK liners. Compared with untreated CFR-PEEK, the PMPC-grafted CFR-PEEK surface revealed higher wettability and lower friction properties under aqueous circumstances. In the hip simulator wear test, wear particles generated from the PMPC-grafted CFR-PEEK liners were fewer than those of the untreated CFR-PEEK liners. There were no significant differences in the size and the morphology of the wear particles between the differences of PMPC-grafting and the counter femoral heads. Zirconia-toughened alumina (ZTA) femoral heads had significantly smoother surfaces compared to cobalt-chromium-molybdenum alloy femoral heads after the hip simulator test. Thus, we conclude that the bearing combination of the PMPC-grafted CFR-PEEK liner and ZTA head is expected to be a lifelong bearing interface in THA. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 1028-1037, 2018. © 2017 Wiley Periodicals, Inc.

  7. Studies of friction and wear characteristics of various wires for wire-brush skids

    NASA Technical Reports Server (NTRS)

    Dreher, R. C.

    1977-01-01

    The friction and wear characteristics of 22 types and sizes of wires for potential use in wire-brush skids were studied. These characteristics were determined by placing brushes made from candidate wires on a belt sander whose moving belt simulated landing roll-out distance. At the same time, the drag force and wear behavior were monitored. Data were obtained over distances up to 3048 m (10,000 ft) at preselected bearing pressures of 172 to 1034 kPa (25 to 150 psi). In general, the friction coefficient developed by the candidate wires was found to be independent of bearing pressure and ranged between 0.4 and 0.6 under the test conditions of this investigation. The friction coefficient was not degraded when the surface was wetted and appears to be independent of wire diameter except perhaps when wire size is relatively large compared with the surface asperities. Generally, the high friction demonstrated by the soft materials was accompanied by high wear rates; conversely, the hard materials provided greater wear resistance but offered lower friction. For all test wires, the wear was shown to increase with increasing bearing pressure, in general, for the same bearing pressure, wear increased with increasing wire diameter and decreased when the surface was wetted.

  8. Influence of pH, bleaching agents, and acid etching on surface wear of bovine enamel

    PubMed Central

    Soares, Ana Flávia; Bombonatti, Juliana Fraga Soares; Alencar, Marina Studart; Consolmagno, Elaine Cristina; Honório, Heitor Marques; Mondelli, Rafael Francisco Lia

    2016-01-01

    ABSTRACT Development of new materials for tooth bleaching justifies the need for studies to evaluate the changes in the enamel surface caused by different bleaching protocols. Objective The aim of this study was to evaluate the bovine dental enamel wear in function of different bleaching gel protocols, acid etching and pH variation. Material and Methods Sixty fragments of bovine teeth were cut, obtaining a control and test areas. In the test area, one half received etching followed by a bleaching gel application, and the other half, only the bleaching gel. The fragments were randomly divided into six groups (n=10), each one received one bleaching session with five hydrogen peroxide gel applications of 8 min, activated with hybrid light, diode laser/blue LED (HL) or diode laser/violet LED (VHL) (experimental): Control (C); 35% Total Blanc Office (TBO35HL); 35% Lase Peroxide Sensy (LPS35HL); 25% Lase Peroxide Sensy II (LPS25HL); 15% Lase Peroxide Lite (LPL15HL); and 10% hydrogen peroxide (experimental) (EXP10VHL). pH values were determined by a pHmeter at the initial and final time periods. Specimens were stored, subjected to simulated brushing cycles, and the superficial wear was determined (μm). ANOVA and Tukey´s tests were applied (α=0.05). Results The pH showed a slight decrease, except for Group LPL15HL. Group LPS25HL showed the highest degree of wear, with and without etching. Conclusion There was a decrease from the initial to the final pH. Different bleaching gels were able to increase the surface wear values after simulated brushing. Acid etching before bleaching increased surface wear values in all groups. PMID:27008254

  9. Influence of pH, bleaching agents, and acid etching on surface wear of bovine enamel.

    PubMed

    Soares, Ana Flávia; Bombonatti, Juliana Fraga Soares; Alencar, Marina Studart; Consolmagno, Elaine Cristina; Honório, Heitor Marques; Mondelli, Rafael Francisco Lia

    2016-01-01

    Development of new materials for tooth bleaching justifies the need for studies to evaluate the changes in the enamel surface caused by different bleaching protocols. The aim of this study was to evaluate the bovine dental enamel wear in function of different bleaching gel protocols, acid etching and pH variation. Sixty fragments of bovine teeth were cut, obtaining a control and test areas. In the test area, one half received etching followed by a bleaching gel application, and the other half, only the bleaching gel. The fragments were randomly divided into six groups (n=10), each one received one bleaching session with five hydrogen peroxide gel applications of 8 min, activated with hybrid light, diode laser/blue LED (HL) or diode laser/violet LED (VHL) (experimental): Control (C); 35% Total Blanc Office (TBO35HL); 35% Lase Peroxide Sensy (LPS35HL); 25% Lase Peroxide Sensy II (LPS25HL); 15% Lase Peroxide Lite (LPL15HL); and 10% hydrogen peroxide (experimental) (EXP10VHL). pH values were determined by a pHmeter at the initial and final time periods. Specimens were stored, subjected to simulated brushing cycles, and the superficial wear was determined (μm). ANOVA and Tukey´s tests were applied (α=0.05). The pH showed a slight decrease, except for Group LPL15HL. Group LPS25HL showed the highest degree of wear, with and without etching. There was a decrease from the initial to the final pH. Different bleaching gels were able to increase the surface wear values after simulated brushing. Acid etching before bleaching increased surface wear values in all groups.

  10. Wear model simulating clinical abrasion on composite filling materials.

    PubMed

    Johnsen, Gaute Floer; Taxt-Lamolle, Sébastien F; Haugen, Håvard J

    2011-01-01

    The aim of this study was to establish a wear model for testing composite filling materials with abrasion properties closer to a clinical situation. In addition, the model was used to evaluate the effect of filler volume and particle size on surface roughness and wear resistance. Each incisor tooth was prepared with nine identical standardized cavities with respect to depth, diameter, and angle. Generic composite of 3 different filler volumes and 3 different particle sizes held together with the same resin were randomly filled in respective cavities. A multidirectional wet-grinder with molar cusps as antagonist wore the surface of the incisors containing the composite fillings in a bath of human saliva at a constant temperature of 37°C. The present study suggests that the most wear resistant filling materials should consist of medium filling content (75%) and that particles size is not as critical as earlier reported.

  11. Impact Fretting Wear Behavior of Alloy 690 Tubes in Dry and Deionized Water Conditions

    NASA Astrophysics Data System (ADS)

    Cai, Zhen-Bing; Peng, Jin-Fang; Qian, Hao; Tang, Li-Chen; Zhu, Min-Hao

    2017-07-01

    The impact fretting wear has largely occurred at nuclear power device induced by the flow-induced vibration, and it will take potential hazards to the service of the equipment. However, the present study focuses on the tangential fretting wear of alloy 690 tubes. Research on impact fretting wear of alloy 690 tubes is limited and the related research is imminent. Therefore, impact fretting wear behavior of alloy 690 tubes against 304 stainless steels is investigated. Deionized water is used to simulate the flow environment of the equipment, and the dry environment is used for comparison. Varied analytical techniques are employed to characterize the wear and tribochemical behavior during impact fretting wear. Characterization results indicate that cracks occur at high impact load in both water and dry equipment; however, the water as a medium can significantly delay the cracking time. The crack propagation behavior shows a jagged shape in the water, but crack extended disorderly in dry equipment because the water changed the stress distribution and retarded the friction heat during the wear process. The SEM and XPS analysis shows that the main failure mechanisms of the tube under impact fretting are fatigue wear and friction oxidation. The effect of medium(water) on fretting wear is revealed, which plays a potential and promising role in the service of nuclear power device and other flow equipments.

  12. Tribology and wear of metal-on-metal hip prostheses: influence of cup angle and head position.

    PubMed

    Williams, Sophie; Leslie, Ian; Isaac, Graham; Jin, Zhongmin; Ingham, Eileen; Fisher, John

    2008-08-01

    Clinical studies have indicated that the angular position of the acetabular cup may influence wear in metal-on-metal total hip bearings. A high cup angle in comparison to the anatomical position may lead to the head being constrained by the superior lateral surface and rim of the cup, thus potentially changing the location of the contact zone between the head and the cup. The aim of this study was to test the hypothesis that both a steep cup angle and a lateralized position of the head can increase head contact on the superior rim of the cup, with the consequence of increased wear. Hip-joint simulator studies of metal-on-metal bearings were undertaken with cup angles of 45 degrees and 55 degrees . The femoral head was either aligned to the center of the cup or placed in a position of microlateralization. Wear was measured gravimetrically over 5 million cycles. A steep cup angle of 55 degrees showed significantly higher long-term steady-state wear than a standard cup angle of 45 degrees (p < 0.01). The difference was fivefold. Microlateralization of the head resulted in a fivefold increase in steady-state wear compared with a centralized head. The combination of a steep cup angle and a microlateralized head increased the steady-state wear rate by tenfold compared with a standard cup angle with a centralized head. These studies support the hypothesis that both an increased cup angle and a lateral head position increase wear in metal-on-metal hip prostheses.

  13. A combined experimental and finite element approach to analyse the fretting mechanism of the head-stem taper junction in total hip replacement.

    PubMed

    Bitter, Thom; Khan, Imran; Marriott, Tim; Lovelady, Elaine; Verdonschot, Nico; Janssen, Dennis

    2017-09-01

    Fretting corrosion at the taper interface of modular hip implants has been implicated as a possible cause of implant failure. This study was set up to gain more insight in the taper mechanics that lead to fretting corrosion. The objectives of this study therefore were (1) to select experimental loading conditions to reproduce clinically relevant fretting corrosion features observed in retrieved components, (2) to develop a finite element model consistent with the fretting experiments and (3) to apply more complicated loading conditions of activities of daily living to the finite element model to study the taper mechanics. The experiments showed similar wear patterns on the taper surface as observed in retrievals. The finite element wear score based on Archard's law did not correlate well with the amount of material loss measured in the experiments. However, similar patterns were observed between the simulated micromotions and the experimental wear measurements. Although the finite element model could not be validated, the loading conditions based on activities of daily living demonstrate the importance of assembly load on the wear potential. These findings suggest that finite element models that do not incorporate geometry updates to account for wear loss may not be appropriate to predict wear volumes of taper connections.

  14. Technical note: Comparison of metal-on-metal hip simulator wear measured by gravimetric, CMM and optical profiling methods

    NASA Astrophysics Data System (ADS)

    Alberts, L. Russell; Martinez-Nogues, Vanesa; Baker Cook, Richard; Maul, Christian; Bills, Paul; Racasan, R.; Stolz, Martin; Wood, Robert J. K.

    2018-03-01

    Simulation of wear in artificial joint implants is critical for evaluating implant designs and materials. Traditional protocols employ the gravimetric method to determine the loss of material by measuring the weight of the implant components before and after various test intervals and after the completed test. However, the gravimetric method cannot identify the location, area coverage or maximum depth of the wear and it has difficulties with proportionally small weight changes in relatively heavy implants. In this study, we compare the gravimetric method with two geometric surface methods; an optical light method (RedLux) and a coordinate measuring method (CMM). We tested ten Adept hips in a simulator for 2 million cycles (MC). Gravimetric and optical methods were performed at 0.33, 0.66, 1.00, 1.33 and 2 MC. CMM measurements were done before and after the test. A high correlation was found between the gravimetric and optical methods for both heads (R 2  =  0.997) and for cups (R 2  =  0.96). Both geometric methods (optical and CMM) measured more volume loss than the gravimetric method (for the heads, p  =  0.004 (optical) and p  =  0.08 (CMM); for the cups p  =  0.01 (optical) and p  =  0.003 (CMM)). Two cups recorded negative wear at 2 MC by the gravimetric method but none did by either the optical method or by CMM. The geometric methods were prone to confounding factors such as surface deformation and the gravimetric method could be confounded by protein absorption and backside wear. Both of the geometric methods were able to show the location, area covered and depth of the wear on the bearing surfaces, and track their changes during the test run; providing significant advantages to solely using the gravimetric method.

  15. Accelerated degradation of polyetheretherketone and its composites in the deep sea

    NASA Astrophysics Data System (ADS)

    Liu, Hao; Wang, Jianzhang; Jiang, Pengfei; Yan, Fengyuan

    2018-04-01

    The performance of polymer composites in seawater, under high hydrostatic pressure (typically few tens of MPa), for simulating exposures at great depths in seas and oceans, has been little studied. In this paper, polyetheretherketone (PEEK) and its composites reinforced by carbon fibres and glass fibres were prepared. The seawater environment with different seawater hydrostatic pressure ranging from normal pressure to 40 MPa was simulated with special equipment, in which the seawater absorption and wear behaviour of PEEK and PEEK-based composites were examined in situ. The effects of seawater hydrostatic pressure on the mechanical properties, wear resistance and microstructure of PEEK and its composites were focused on. The results showed that seawater absorption of PEEK and its composites were greatly accelerated by increased hydrostatic pressure in the deep sea. Affected by seawater absorption, both for neat PEEK and composites, the degradation on mechanical properties, wear resistance and crystallinity were induced, the degree of which was increasingly serious with the increase of hydrostatic pressure of seawater environment. There existed a good correlation in an identical form of exponential function between the wear rate and the seawater hydrostatic pressure. Moreover, the corresponding mechanisms of the effects of deep-sea hydrostatic pressure were also discussed.

  16. Fretting wear behaviors of a dual-cooled nuclear fuel rod under a simulated rod vibration

    NASA Astrophysics Data System (ADS)

    Lee, Young-Ho; Kim, Hyung-Kyu; Kang, Heung-Seok; Yoon, Kyung-Ho; Kim, Jae-Yong; Lee, Kang-Hee

    2012-06-01

    Recently, a dual-cooled fuel (i.e., annular fuel) that is compatible with current operating PWR plants has been proposed in order to realize both a considerable amount of power uprating and an increase of safety margins. As the design concept should be compatible with current operating PWR plants, however, it shows a narrow gap between the fuel rods when compared with current solid nuclear fuel arrays and needs to modify the spacer grid shapes and their positions. In this study, fretting wear tests have been performed to evaluate the wear resistance of a dual-cooled fuel by using a proposed spring and dimple of spacer grids that have a cantilever type and hemispherical shape, respectively. As a result, the wear volume of the spring specimen gradually increases as the contact condition is changed from a certain gap, just contact to positive force. However, in the dimple specimen, just contact condition shows a large wear volume. In addition, a circular rod motion at upper region of contact surface is gradually increased and its diametric size depends on the wear depth increase. Based on the test results, the fretting wear resistance of the proposed spring and dimple is analyzed by comparing the wear measurement results and rod motion in detail.

  17. Control of brushing variables for the in vitro assessment of toothpaste abrasivity using a novel laboratory model.

    PubMed

    Parry, Jason; Harrington, Edward; Rees, Gareth D; McNab, Rod; Smith, Anthony J

    2008-02-01

    Design and construct a tooth-brushing simulator incorporating control of brushing variables including brushing force, speed and temperature, thereby facilitating greater understanding of their importance in toothpaste abrasion testing methodologies. A thermostable orbital shaker was selected as a base unit and 16- and 24-specimen brushing rigs were constructed to fit inside, consisting of: a square bath partitioned horizontally to provide brushing channels, specimen holders for 25 mm diameter mounted specimens to fit the brushing channels and individually weighted brushing arms, able to support four toothbrush holders suspended over the brushing channels. Brush head holders consisted of individually weighted blocks of Delrin, or PTFE onto which toothbrush heads were fixed. Investigating effects of key design criteria involved measuring abrasion depths of polished human enamel and dentine. The brushing simulator demonstrated good reproducibility of abrasion on enamel and dentine across consecutive brushing procedures. Varying brushing parameters had a significant impact on wear results: increased brushing force demonstrated a trend towards increased wear, with increased reproducibility for greater abrasion levels, highlighting the importance of achieving sufficient wear to optimise accuracy; increasing brushing temperature demonstrated increased enamel abrasion for silica and calcium carbonate systems, which may be related to slurry viscosities and particle suspension; varying brushing speed showed a small effect on abrasion of enamel at lower brushing speed, which may indicate the importance of maintenance of the abrasive in suspension. Adjusting key brushing variables significantly affected wear behaviour. The brushing simulator design provides a valuable model system for in vitro assessment of toothpaste abrasivity and the influence of variables in a controlled manner. Control of these variables will allow more reproducible study of in vitro tooth wear processes.

  18. Understanding the differences between the wear of metal-on-metal and ceramic-on-metal total hip replacements.

    PubMed

    Figueiredo-Pina, C G; Yan, Y; Neville, A; Fisher, J

    2008-04-01

    Hip simulator studies have been carried out extensively to understand and test artificial hip implants in vitro as an efficient alternative to obtaining long-term results in vivo. Recent studies have shown that a ceramic-on-metal material combination lowers the wear by up to 100 times in comparison with a typical metal-on-metal design. The reason for this reduction remains unclear and for this reason this study has undertaken simple tribometer tests to understand the fundamental material loss mechanisms in two material combinations: metal-on-metal and ceramic-on-ceramic. A simple-configuration reciprocating pin-on-plate wear study was performed under open-circuit potential (OCP) and with applied cathodic protection (CP) in a serum solution using two tribological couples: firstly, cobalt-chromium (Co-Cr) pins against Co-Cr plates; secondly, Co-Cr pins against alumina (Al2O3) plates. The pin and plate surfaces prior to and after testing were examined by profilometry and scanning electron microscopy. The results showed a marked reduction in wear when CP was applied, indicating that total material degradation under the OCP condition was attributed to corrosion processes. The substitution of the Co-Cr pin with an Al2O3 plate also resulted in a dramatic reduction in wear, probably due to the reduction in the corrosion-wear interactions between the tribological pair.

  19. Reduced wear of enamel with novel fine and nano-scale leucite glass-ceramics.

    PubMed

    Theocharopoulos, Antonios; Chen, Xiaohui; Hill, Robert; Cattell, Michael J

    2013-06-01

    Leucite glass-ceramics used to produce all-ceramic restorations can suffer from brittle fracture and wear the opposing teeth. High strength and fine crystal sized leucite glass-ceramics have recently been reported. The objective of this study is to investigate whether fine and nano-scale leucite glass-ceramics with minimal matrix microcracking are associated with a reduction in in vitro tooth wear. Human molar cusps (n=12) were wear tested using a Bionix-858 testing machine (300,000 simulated masticatory cycles) against experimental fine crystal sized (FS), nano-scale crystal sized (NS) leucite glass-ceramics and a commercial leucite glass-ceramic (Ceramco-3, Dentsply, USA). Wear was imaged using Secondary Electron Imaging (SEI) and quantified using white-light profilometry. Both experimental groups were found to produce significantly (p<0.05) less volume and mean-height tooth loss compared to Ceramco-3. The NS group had significantly (p<0.05) less tooth mean-height loss and less combined (tooth and ceramic) loss than the FS group. Increased waviness and damage was observed on the wear surfaces of the Ceramco-3 glass-ceramic disc/tooth group in comparison to the experimental groups. This was also indicated by higher surface roughness values for the Ceramco-3 glass-ceramic disc/tooth group. Fine and nano-sized leucite glass-ceramics produced a reduction in in vitro tooth wear. The high strength low wear materials of this study may help address the many problems associated with tooth enamel wear and restoration failure. Copyright © 2013 Elsevier Ltd. All rights reserved.

  20. Wear Behaviours and Oxidation Effects on Different UHMWPE Acetabular Cups Using a Hip Joint Simulator

    PubMed Central

    Jaber, Sami Abdel; Merola, Massimiliano

    2018-01-01

    Given the long-term problem of polyethylene wear, medical interest in the new improved cross-linked polyethylene (XLPE), with or without the adding of vitamin E, has risen. The main aim of this study is to gain further insights into the mutual effects of radiation cross-linking and addition of vitamin E on the wear performance of ultra-high-molecular-weight polyethylene (UHMWPE). We tested four different batches of polyethylene (namely, a standard one, a vitamin E-stabilized, and two cross-linked) in a hip joint simulator for five million cycles where bovine calf serum was used as lubricant. The acetabular cups were then analyzed using a confocal profilometer to characterize the surface topography. Moreover; the cups were analyzed by using Fourier Transformed Infrared Spectroscopy and Differential Scanning Calorimetry in order to assess the chemical characteristics of the pristine materials. Comparing the different cups’ configuration, mass loss was found to be higher for standard polyethylene than for the other combinations. Mass loss negatively correlated to the cross-link density of the polyethylenes. None of the tested formulations showed evidence of oxidative degradation. We found no correlation between roughness parameters and wear. Furthermore, we found significantly differences in the wear behavior of all the acetabular cups. XLPEs exhibited lower weight loss, which has potential for reduced wear and decreased osteolysis. However, surface topography revealed smoother surfaces of the standard and vitamin E stabilized polyethylene than on the cross-linked samples. This observation suggests incipient crack generations on the rough and scratched surfaces of the cross-linked polyethylene liners. PMID:29547536

  1. Effect of consolidation on adhesive and abrasive wear of ultra high molecular weight polyethylene.

    PubMed

    Gul, Rizwan M; McGarry, Frederick J; Bragdon, Charles R; Muratoglu, Orhun K; Harris, William H

    2003-08-01

    Total hip replacement (THR) is widely performed to recover hip joint functions lost by trauma or disease and to relieve pain. The major cause of failure in THR is the wear of the ultra high molecular weight polyethylene (UHMWPE) component. The dominant wear mechanism in THR occurs through adhesion and abrasion. While poor consolidation of UHMWPE is known to increase the incidence of a different damage mode, delamination, which is the dominant wear mechanism in tibial inserts but uncommon in THR, the effect of consolidation on adhesive and abrasive wear of UHMWPE is not clear. In this study UHMWPE resin was subjected to hot isostatic pressing under a pressure of 138MPa at different temperatures (210 degrees C, 250 degrees C, and 300 degrees C) to achieve varying degrees of consolidation. The extent of consolidation was determined by optical microscopy using thin sections, and by scanning electron microscopy using cryofractured and solvent etched specimens. Wear behavior of the samples with varying degree of consolidation was determined using a bi-directional pin-on-disc machine simulating conditions in a hip joint. Increasing the processing temperature decreased the incidence of fusion defects and particle boundaries reflecting the powder flakes of the virgin resin, improving the consolidation. However, the bi-directional pin-on-disc wear rate did not change with the processing temperature, indicating that adhesive and abrasive wear is independent of the extent of consolidation in the range of parameters studied here.

  2. [Effect of surface modification using laser on wear resistance of titanium].

    PubMed

    Sato, Yohei

    2005-02-01

    Severe wear of cast commercial pure (CP) titanium teeth was observed in a clinical survey. This study evaluated the wear resistance of cast CP titanium and titanium alloy teeth after the surface was modified using laser technology. Teeth patterns were duplicated from artificial first molars (Livdent FB30, GC, Japan). All teeth specimens were cast with CP Ti grade 3 (T-Alloy H, GC) and Ti-6Al-7Nb (T-Alloy Tough, GC). After the occlusal surface was blasted with Al(2)O(3), the occlusal contact points were modified using a laser (Neo laser L, Girrbach, Germany) at the following irradiation conditions (voltage: 260 V; pulse: 7 ms; focus: 1.5 mm). These parameters were determined by preliminary study. As a control, Type IV gold alloy (PGA-3, Ishifuku, Japan) was also cast conventionally. Both maxillary and mandibular teeth were worn using an in vitro two-body wear testing apparatus that simulated chewing function (60 strokes/min; grinding distance: 2 mm under flowing water). Wear resistance was assessed as volume loss (mm(3)) at 5 kgf (grinding force) after 50,000 strokes. The results (n=5) were analyzed by ANOVA/Scheffé's test (alpha=0.05). The gold alloy showed the best wear resistance of all the metals tested. Of all the titanium specimens tested, the modified surface indicated significantly greater wear resistance than did conventional titanium teeth without surface modification (p<0.05). Wear resistance was increased by modification of the surface using a laser. If severe wear of titanium teeth was observed clinically, little wear occurred when the occlusal facets were irradiated using a laser.

  3. GMT azimuth bogie wheel-rail interface wear study

    NASA Astrophysics Data System (ADS)

    Teran, Jose; Lindh, Cory; Morgan, Chris; Manuel, Eric; Bigelow, Bruce C.; Burgett, William S.

    2016-07-01

    Performance of the GMT azimuth drive system is vital for the operation of the telescope and, as such, all components subject to wear at the drive interface merit a high level of scrutiny for achieving a proper balance between capital costs, maintenance costs, and the risk for downtime during planned and unplanned maintenance or replacement procedures. Of particular importance is the interface between the azimuth wheels and rail, as usage frequency is high, the full weight of the enclosure must be transferred through small patches of contact, and replacement of the rail would pose a greater logistical challenge than the replacement of smaller components such as bearings and gearmotors. This study investigates tradeoffs between various wheel-rail and roller-track interfaces, including performance, complexity, and anticipated wear considerations. First, a survey of railway and overhead crane industry literature is performed and general detailing recommendations are made to minimize wear and the risk of rolling contact fatigue. Second, Adams/VI-Rail is used to simulate lifetime wear of four specific configurations under consideration for the GMT azimuth wheel-rail interface; all studied configurations are shown to be viable, and their relative merits are discussed.

  4. The effects of artificial wing wear on the flight capacity of the honey bee Apis mellifera.

    PubMed

    Vance, Jason T; Roberts, Stephen P

    2014-06-01

    The wings of bees and other insects accumulate permanent wear, which increases the rate of mortality and impacts foraging behavior, presumably due to effects on flight performance. In this study, we investigated how experimental wing wear affects flight performance in honey bees. Variable density gases and high-speed videography were used to determine the maximum hovering flight capacity and wing kinematics of bees from three treatment groups: no wing wear, symmetric and asymmetric wing wear. Wing wear was simulated by clipping the distal-trailing edge of one or both of the wings. Across all bees from treatment groups combined, wingbeat frequency was inversely related to wing area. During hovering in air, bees with symmetric and asymmetric wing wear responded kinematically so as to produce wingtip velocities similar to those bees with no wing wear. However, maximal hovering flight capacity (revealed during flight in hypodense gases) decreased in direct proportion to wing area and inversely to wing asymmetry. Bees with reduced wing area and high asymmetry produced lower maximum wingtip velocity than bees with intact or symmetric wings, which caused a greater impairment in maximal flight capacity. These results demonstrate that the magnitude and type of wing wear affects maximal aerodynamic power production and, likely, the control of hovering flight. Wing wear reduces aerodynamic reserve capacity and, subsequently, the capacity for flight behaviors such as load carriage, maneuverability, and evading predators. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. Fractionation and characterization of particles simulating wear of total joint replacement (TJR) following ASTM standards.

    PubMed

    Saha, Subrata; Musib, Mrinal

    2011-01-01

    Reactions of bone cells to orthopedic wear debris produced by the articulating motion of total joint replacements (TJRs) are largely responsible for the long-term failure of such replacements. Metal and polyethylene (PE) wear particles isolated from fluids from total joint simulators, as well as particles that are fabricated by other methods, are widely used to study such in vitro cellular response. Prior investigations have revealed that cellular response to wear debris depends on the size, shape, and dose of the particles. Hence, to have a better understanding of the wear-mediated osteolytic process it is important that these particles are well characterized and clinically relevant, both qualitatively, and quantitatively. In this study we have fractionated both ultra-high molecular weight polyethylene (UHMWPE) and Ti particles, into micron (1.0-10.0 μm), submicron (0.2-1.0 μm), and nanoparticle (0.01-0.2 μm) fractions, and characterized them based on the following size-shape descriptors as put forth in ASTM F1877: i) equivalent circle diameter (ECD), ii) aspect ratio (AR), iii) elongation (E), iv) roundness (R), and v) form factor (FF). The mean (± SD) ECDs (in μm) for micron, submicron, and nanoparticles of UHMWPE were 1.652 ± 0.553, 0.270 ± 0.180, and 0.061 ± 0.035, respectively, and for Ti were 1.894 ± 0.667, 0.278 ± 0.180, and 0.055 ± 0.029, respectively. The values for other descriptors were similar (no statistically significant difference). The nanofraction particles were found to be more sphere-like (higher R and FF values, and lower E and AR values) as compared to larger particles. Future experiments will involve use of these well characterized particles for in vitro studies.

  6. Development of high gradient magnetic separation system for removing the metallic wear debris to be present in highly viscous fluid

    NASA Astrophysics Data System (ADS)

    Hayashi, S.; Mishima, F.; Akiyama, Y.; Nishijima, S.

    2010-11-01

    In the industrial plants processing highly viscous fluid such as foods or industrial materials, there is an issue of contamination by metallic wear debris originating from pipe of manufacturing line. It is necessary to remove the metallic wear debris in highly viscous fluid, since these debris causes quality loss. In this study, we developed a high gradient magnetic separation system by using superconducting magnet to remove the metallic wear debris. The particle trajectory simulation and the magnetic separation experiment were conducted with polyvinyl alcohol as a model material. As a result, ca. 100% and 92.2% of the separation efficiency was achieved respectively for the highly viscous fluid of 1 Pa s and 6 Pa s in viscosity, with 14 and 30 mesh magnetic filters.

  7. Friction measurement in a hip wear simulator.

    PubMed

    Saikko, Vesa

    2016-05-01

    A torque measurement system was added to a widely used hip wear simulator, the biaxial rocking motion device. With the rotary transducer, the frictional torque about the drive axis of the biaxial rocking motion mechanism was measured. The principle of measuring the torque about the vertical axis above the prosthetic joint, used earlier in commercial biaxial rocking motion simulators, was shown to sense only a minor part of the total frictional torque. With the present method, the total frictional torque of the prosthetic hip was measured. This was shown to consist of the torques about the vertical axis above the joint and about the leaning axis. Femoral heads made from different materials were run against conventional and crosslinked polyethylene acetabular cups in serum lubrication. Regarding the femoral head material and the type of polyethylene, there were no categorical differences in frictional torque with the exception of zirconia heads, with which the lowest values were obtained. Diamond-like carbon coating of the CoCr femoral head did not reduce friction. The friction factor was found to always decrease with increasing load. High wear could increase the frictional torque by 75%. With the present system, friction can be continuously recorded during long wear tests, so the effect of wear on friction with different prosthetic hips can be evaluated. © IMechE 2016.

  8. Effects of Heat Treatment on Corrosion and Wear Behaviors of Mg-6Gd-2Zn-0.4Zr Alloy in Simulated Body Fluid

    NASA Astrophysics Data System (ADS)

    Zhao, Li; Chen, Wei; Dai, Jianwei; Wang, Zhangzhong; Zhang, Xiaobo

    2017-11-01

    Mg-6Gd-2Zn-0.4Zr (wt.%, GZ62K) alloy was processed by solution treatment under different temperatures. The microstructure, hardness, corrosion and wear behaviors in simulated body fluid (SBF) have been studied. The results indicate that the (Mg, Zn)3Gd phase decreases, the precipitated phases gradually increase, and the long-period stacking ordered structure disappears with the increase of solution temperature. The alloy has better corrosion resistance after solution treatment, and that solution treated at 490 °C for 12 h shows the best corrosion resistance. The friction coefficient of the alloy under dry sliding condition decreases slightly, but the mass loss increases with increasing the solution temperature. The alloy solution treated at 460 °C for 12 h exhibits the lowest friction coefficient and mass loss in SBF, and it also has the best wear resistance under dry sliding condition.

  9. Influence of polishing on surface roughness following toothbrushing wear of composite resins.

    PubMed

    Dalla-Vecchia, Karine Battestin; Taborda, Talita Damas; Stona, Deborah; Pressi, Heloísa; Burnett Júnior, Luiz Henrique; Rodrigues-Junior, Sinval Adalberto

    2017-01-01

    This study aimed to evaluate the influence of different polishing systems on the surface roughness of composite resins following procedures to simulate the effects of toothbrushing over time. Four currently available commercial composites were used to make 128 cylindrical specimens. The specimens were randomly allocated to polishing with a 1-step polisher or 1 of 3 multistep polishers (n = 8 per group). The baseline surface roughness was measured, and the specimens were submitted to 5000, 10,000, and 20,000 brushing cycles to represent toothbrushing throughout 6, 12, and 24 months, respectively. Results showed that surface roughness was influenced by the type of composite and polishing system and was not influenced by the simulated toothbrushing time. However, the surface roughness, as challenged by toothbrushing wear, was affected by the interaction among the composite, the polisher, and the toothbrushing time. The 1-step polisher produced the highest surface roughness and influenced toothbrushing wear resistance of some composites.

  10. Investigation of the performance of articular cartilage and synthetic biomaterials in multi-directional sliding motion as in orthopedic implants

    NASA Astrophysics Data System (ADS)

    Schwartz, Christian John

    The performance of several synthetic biomaterials and bovine articular cartilage were investigated in terms of their suitability for use as articulating surfaces in artificial joints. The Dual-Axis Wear Simulator (DAWS), a wear testing machine that simulates conditions in a synovial joint, was designed and fabricated to enable investigators to measure the wear of such materials in multi-directional sliding while immersed in a bovine serum lubricant solution. This machine was used initially to determine the wear mechanisms and wear amounts of ultra-high molecular weight polyethylene (UHMWPE), polytetrafluoroethylene (PTFE), polyoxymethylene (POM), and the compliant elastomer Pellethane(TM) 2363-80A. It was found that the compliant material produced lower wear. Dynamic mechanical analysis was used to determine that bovine articular cartilage had a very significant amount of viscoelasticity to support static loads and damp impact loads. Furthermore, the use of a compliant counterface led to lower wear in the cartilage as compared to a rigid counterface. Pt-Zr quasicrystals were used as fillers in UHMWPE, and the wear, stiffness, and impact toughness of the filled polymer were shown to be comparable or better than those of UHMWPE that had been irradiation crosslinked. Crosslinked UHMWPE was investigated for its susceptibility to oxidative degradation and increased wear. It was found that thermal stabilization of the polymer could be eliminated if a mild amount crosslinking was used. Furthermore, there was no degradation in wear resistance of mildly crosslinked and non-stabilized UHMWPE even after accelerated aging. Based on the results of this work and lessons learned about compliance and wear resistance, blends were produced by using surface-activated UHMWPE particles as fillers in elastomeric PUR. The blends showed better wear resistance than UHMWPE, as well as increased stiffness and damping over PUR. The results of this work indicated that there is great potential for the development of new biomaterials and materials treatment methods to produce more durable articulating components in artificial joints.

  11. Improving Tribological Properties of Multialkylated Cyclopentanes under Simulated Space Environment: Two Feasible Approaches.

    PubMed

    Fan, Xiaoqiang; Wang, Liping; Li, Wen; Wan, Shanhong

    2015-07-08

    Space mechanisms require multialkylated cyclopentanes (MACs) more lubricious, more reliable, more durable, and better adaptive to harsh space environments. In this study, two kinds of additives were added into MACs for improving the tribological properties under simulated space environments: (a) solid nanoparticles (tungsten disulfide (WS2), tungsten trioxide (WO3), lanthanum oxide (La2O3), and lanthanum trifluoride (LaF3)) for steel/steel contacts; (b) liquid additives like zinc dialkyldithiophosphate (ZDDP) and molybdenum dialkyldithiocarbamate (MoDTC) for steel/steel and steel/diamond-like carbon (DLC) contacts. The results show that, under harsh simulated space environments, addition of the solid nanoparticles into MACs allows the wear to be reduced by up to one order magnitude, while liquid additives simultaneously reduce friction and wear by 80% and 93%, respectively. Friction mechanisms were proposed according to surface/interface analysis techniques, such as X-ray photoelectron spectroscopy (XPS) and time-of-flight secondary ion mass spectroscopy (TOF-SIMS). The role of solid nanoparticles in reducing friction and wear mainly depends on their surface enhancement effect, and the liquid additives are attributed to the formation of tribochemical reaction film derived from ZDDP and MoDTC on the sliding surfaces.

  12. Corrosion and wear behaviors of boronized AISI 316L stainless steel

    NASA Astrophysics Data System (ADS)

    Kayali, Yusuf; Büyüksaǧiş, Aysel; Yalçin, Yılmaz

    2013-09-01

    In this study, the effects of a boronizing treatment on the corrosion and wear behaviors of AISI 316L austenitic stainless steel (AISI 316L) were examined. The corrosion behavior of the boronized samples was studied via electrochemical methods in a simulation body fluid (SBF) and the wear behavior was examined using the ball-on-disk wear method. It was observed that the boride layer that formed on the AISI 316L surface had a flat and smooth morphology. Furthermore, X-ray diffraction analyses show that the boride layer contained FeB, Fe2B, CrB, Cr2B, NiB, and Ni2B phases. Boride layer thickness increased with an increasing boronizing temperature and time. The boronizing treatment also increased the surface hardness of the AISI 316L. Although there was no positive effect of the coating on the corrosion resistance in the SBF medium. Furthermore, a decrease in the friction coefficient was recorded for the boronized AISI 316L. As the boronizing temperature increased, the wear rate decreased in both dry and wet mediums. As a result, the boronizing treatment contributed positively to the wear resistance by increasing the surface hardness and by decreasing the friction coefficient of the AISI 316L.

  13. Finite element simulation of cutting grey iron HT250 by self-prepared Si3N4 ceramic insert

    NASA Astrophysics Data System (ADS)

    Wang, Bo; Wang, Li; Zhang, Enguang

    2017-04-01

    The finite element method has been able to simulate and solve practical machining problems, achieve the required accuracy and the highly reliability. In this paper, the simulation models based on the material properties of the self-prepared Si3N4 insert and HT250 were created. Using these models, the results of cutting force, cutting temperature and tool wear rate were obtained, and tool wear mode was predicted after cutting simulation. These approaches may develop as the new method for testing new cutting-tool materials, shortening development cycle and reducing the cost.

  14. The wear of cross-linked polyethylene against itself.

    PubMed

    Joyce, T J; Ash, H E; Unsworth, A

    1996-01-01

    Cross-linked polyethylene (XLPE) may have an application as a material for an all-plastic surface replacement finger joint. It is inexpensive, biocompatible and can be injection-moulded into the complex shapes that are found on the ends of the finger bones. Further, the cross-linking of polyethylene has significantly improved its mechanical properties. Therefore, the opportunity exists for an all-XLPE joint, and so the wear characteristics of XLPE sliding against itself have been investigated. Wear tests were carried out on both reciprocating pin-on-plate machines and a finger function simulator. The reciprocating pin-on-plate machines had pins loaded at 10 N and 40 N. All pin-on-plate tests show wear factors from the plates very much greater than those of the pins. After 349 km of sliding, a mean wear factor of 0.46 x 10(-6) mm3/N m was found for the plates compared with 0.021 x 10(-6) mm3/N m for the pins. A fatigue mechanism may be causing this phenomenon of greater plate wear. Tests using the finger function simulator give an average wear rate of 0.22 x 10(-6) mm3/N m after 368 km. This sliding distance is equivalent to 12.5 years of use in vivo. The wear factors found were comparable with those of ultra-high molecular weight polyethylene (UHMWPE) against a metallic counterface and, therefore, as the loads across the finger joint are much less than those across the knee or the hip, it is probable that an all-XLPE finger joint will be viable from a wear point of view.

  15. Influences of die channel angles on microstructures and wear behaviors of AZ61 wrought magnesium alloy fabricated by extrusion-shear process

    NASA Astrophysics Data System (ADS)

    Hu, Hong-J.; Sun, Z.; Ou, Z.-W.

    2016-12-01

    Extrusion-shear (ES) process for magnesium alloy is a newly developed plastic deformation process, and ES process combines direct extrusion and two steps of ECAE (equal channel angular extrusion). To investigate the effects of the die channel angles on the microstructures and wear behaviors of AZ61 wrought magnesium alloy, the samples used in this study were fabricated by ES process with different die channel angles (120° and 135°). The microstructures of the samples were characterized by optical microscopy (OM), X-ray diffraction (XRD) and (SEM). The cumulative strains in the ES process were predicted by approaches of numerical simulation and theoretical calculation. To characterize the wear resistance of the samples, pin-on-disk tests under dry sliding conditions with various normal loads and reciprocating frequencies were conducted. To define the wear mechanisms of AZ61 magnesium alloy, the worn surfaces after wear tests were analyzed by SEM and energy-dispersive X-ray spectrometer (EDS). Based on the results obtained, die channel angles have significant influences on the grain refinements and wear behaviors of the samples. Decreasing channel angles of the ES die will not only refine the microstructures of magnesium alloys effectively and improve their harnesses, but also improve their wear resistance as decreasing channel angles results in higher friction coefficients and wear rates. With the increase in applied loads and frequencies, wear mechanisms change from mild wear (adhesion, abrasion and oxidation) to severe wear (delamination, plastic deformation and melting). In summary, the wear resistance of ES-processed AZ61 magnesium alloy could be improved by decreasing channel angles of ES dies.

  16. Large-eddy simulation, fuel rod vibration and grid-to-rod fretting in pressurized water reactors

    DOE PAGES

    Christon, Mark A.; Lu, Roger; Bakosi, Jozsef; ...

    2016-10-01

    Grid-to-rod fretting (GTRF) in pressurized water reactors is a flow-induced vibration phenomenon that results in wear and fretting of the cladding material on fuel rods. GTRF is responsible for over 70% of the fuel failures in pressurized water reactors in the United States. Predicting the GTRF wear and concomitant interval between failures is important because of the large costs associated with reactor shutdown and replacement of fuel rod assemblies. The GTRF-induced wear process involves turbulent flow, mechanical vibration, tribology, and time-varying irradiated material properties in complex fuel assembly geometries. This paper presents a new approach for predicting GTRF induced fuelmore » rod wear that uses high-resolution implicit large-eddy simulation to drive nonlinear transient dynamics computations. The GTRF fluid–structure problem is separated into the simulation of the turbulent flow field in the complex-geometry fuel-rod bundles using implicit large-eddy simulation, the calculation of statistics of the resulting fluctuating structural forces, and the nonlinear transient dynamics analysis of the fuel rod. Ultimately, the methods developed here, can be used, in conjunction with operational management, to improve reactor core designs in which fuel rod failures are minimized or potentially eliminated. Furthermore, robustness of the behavior of both the structural forces computed from the turbulent flow simulations and the results from the transient dynamics analyses highlight the progress made towards achieving a predictive simulation capability for the GTRF problem.« less

  17. Large-eddy simulation, fuel rod vibration and grid-to-rod fretting in pressurized water reactors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Christon, Mark A.; Lu, Roger; Bakosi, Jozsef

    Grid-to-rod fretting (GTRF) in pressurized water reactors is a flow-induced vibration phenomenon that results in wear and fretting of the cladding material on fuel rods. GTRF is responsible for over 70% of the fuel failures in pressurized water reactors in the United States. Predicting the GTRF wear and concomitant interval between failures is important because of the large costs associated with reactor shutdown and replacement of fuel rod assemblies. The GTRF-induced wear process involves turbulent flow, mechanical vibration, tribology, and time-varying irradiated material properties in complex fuel assembly geometries. This paper presents a new approach for predicting GTRF induced fuelmore » rod wear that uses high-resolution implicit large-eddy simulation to drive nonlinear transient dynamics computations. The GTRF fluid–structure problem is separated into the simulation of the turbulent flow field in the complex-geometry fuel-rod bundles using implicit large-eddy simulation, the calculation of statistics of the resulting fluctuating structural forces, and the nonlinear transient dynamics analysis of the fuel rod. Ultimately, the methods developed here, can be used, in conjunction with operational management, to improve reactor core designs in which fuel rod failures are minimized or potentially eliminated. Furthermore, robustness of the behavior of both the structural forces computed from the turbulent flow simulations and the results from the transient dynamics analyses highlight the progress made towards achieving a predictive simulation capability for the GTRF problem.« less

  18. The High performance of nanocrystalline CVD diamond coated hip joints in wear simulator test.

    PubMed

    Maru, M M; Amaral, M; Rodrigues, S P; Santos, R; Gouvea, C P; Archanjo, B S; Trommer, R M; Oliveira, F J; Silva, R F; Achete, C A

    2015-09-01

    The superior biotribological performance of nanocrystalline diamond (NCD) coatings grown by a chemical vapor deposition (CVD) method was already shown to demonstrate high wear resistance in ball on plate experiments under physiological liquid lubrication. However, tests with a close-to-real approach were missing and this constitutes the aim of the present work. Hip joint wear simulator tests were performed with cups and heads made of silicon nitride coated with NCD of ~10 μm in thickness. Five million testing cycles (Mc) were run, which represent nearly five years of hip joint implant activity in a patient. For the wear analysis, gravimetry, profilometry, scanning electron microscopy and Raman spectroscopy techniques were used. After 0.5 Mc of wear test, truncation of the protruded regions of the NCD film happened as a result of a fine-scale abrasive wear mechanism, evolving to extensive plateau regions and highly polished surface condition (Ra<10nm). Such surface modification took place without any catastrophic features as cracking, grain pullouts or delamination of the coatings. A steady state volumetric wear rate of 0.02 mm(3)/Mc, equivalent to a linear wear of 0.27 μm/Mc favorably compares with the best performance reported in the literature for the fourth generation alumina ceramic (0.05 mm(3)/Mc). Also, squeaking, quite common phenomenon in hard-on-hard systems, was absent in the present all-NCD system. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. A hip wear simulator with 100 test stations.

    PubMed

    Saikko, V

    2005-09-01

    A novel high-capacity hip wear simulator of the pin-on-disc type was designed, built, and validated. This so-called Super-CTPOD (circularly translating pin-on-disc) device has as many as 100 separate test stations, being an advanced version of the previously validated 12-station CTPOD. A validity test was done so that in all stations the specimens and the test conditions were as similar as possible. Hence, for the first time in this field, an adequate number of similar tests was done for a proper statistical analysis of wear data. The pins were conventional, gamma-sterilized ultra-high molecular weight polyethylene, and the discs were polished CoCr. The lubricant was diluted calf serum and the test length 3 million cycles. In the course of the test, the pins became highly polished, whereas the discs remained practically unchanged. The majority of the polyethylene wear particles were rounded, with a mean diameter of 0.25 microm. The 100 wear factor values computed from the 100 steady state wear rate values of the pins were normally distributed, the mean +/- 95 per cent confidence interval being 1.63 +/- 0.017 x 10(-6) mm3 /N m. The standard deviation was 5.4 per cent of the mean. There were no outliers. The wear mechanisms and the wear factor agreed well with clinical findings. Altogether, the Super-CTPOD test system was shown to be a unique combination of validity, low variation, capacity, efficiency, reliability, productivity, economy, ease of operation, and compact size.

  20. Effect of ion implantation on the tribology of metal-on-metal hip prostheses.

    PubMed

    Bowsher, John G; Hussain, Azad; Williams, Paul; Nevelos, Jim; Shelton, Julia C

    2004-12-01

    Nitrogen ion implantation (which considerably hardens the surface of the bearing) may represent one possible method of reducing the wear of metal-on-metal (MOM) hip bearings. Currently there are no ion-implanted MOM bearings used clinically. Therefore a physiological hip simulator test was undertaken using standard test conditions, and the results compared to previous studies using the same methods. N2-ion implantation of high carbon cast Co-Cr-Mo-on-Co-Cr-Mo hip prostheses increased wear by 2-fold during the aggressive running-in phase compared to untreated bearing surfaces, plus showing no wear reductions during steady-state conditions. Although 2 specimens were considered in the current study, it would appear that ion implantation has no clinical benefit for MOM.

  1. Finite Element Analysis Of Influence Of Flank Wear Evolution On Forces In Orthogonal Cutting Of 42CrMo4 Steel

    NASA Astrophysics Data System (ADS)

    Madajewski, Marek; Nowakowski, Zbigniew

    2017-01-01

    This paper presents analysis of flank wear influence on forces in orthogonal turning of 42CrMo4 steel and evaluates capacity of finite element model to provide such force values. Data about magnitude of feed and cutting force were obtained from measurements with force tensiometer in experimental test as well as from finite element analysis of chip formation process in ABAQUS/Explicit software. For studies an insert with complex rake face was selected and flank wear was simulated by grinding operation on its flank face. The aim of grinding inset surface was to obtain even flat wear along cutting edge, which after the measurement could be modeled with CAD program and applied in FE analysis for selected range of wear width. By comparing both sets of force values as function of flank wear in given cutting conditions FEA model was validated and it was established that it can be applied to analyze other physical aspects of machining. Force analysis found that progression of wear causes increase in cutting force magnitude and steep boost to feed force magnitude. Analysis of Fc/Ff force ratio revealed that flank wear has significant impact on resultant force in orthogonal cutting and magnitude of this force components in cutting and feed direction. Surge in force values can result in transfer of substantial loads to machine-tool interface.

  2. Contact of dual mobility implants: effects of cup wear and inclination.

    PubMed

    Uddin, M S

    2015-01-01

    Cup wear and inclination on the pelvic bone are significant factors, which change the contact of the articulating surfaces, thus, impacting the long-term performance of hip implants. This paper presents a finite element (FE) analysis of the contact of the dual mobility implants under the influence of cup wear and inclination. A 3D FE model of the implant was developed with the application of equivalent physiological loading and boundary conditions. Effects of cup inclination angle ranging from 45° to 60° and the wear depth ranging from 0 to 2.46 mm equivalent to up to 30 years of the implant's life on the contact pressure and von Mises stress were investigated. Simulation results show that the contact pressure and von Mises stress decrease significantly with a modest wear depth and remains quite in-sensitive to the cup inclination angle and wear depth up to 1.64 mm. With wear depth further up to 2.46 mm, the cup thickness (i.e. cup thinning on worn region) may be more predominant than increasing of contact area between the cup and the head. The wear on the inner surface of the cup is found to rule out the overall contact pressure and stress in the implant. Furthermore, individual and combined effects of both important parameters are analysed and discussed with respect to available clinical/laboratory studies.

  3. Fretting wear study of surface modified Ni-Ti shape memory alloy.

    PubMed

    Tan, L; Crone, W C; Sridharan, K

    2002-05-01

    A combination of shape memory characteristics, pseudoelasticity, and good damping properties make near-equiatomic nickel-titanium (Ni-Ti) alloy a desirable candidate material for certain biomedical device applications. The alloy has moderately good wear resistance, however, further improvements in this regard would be beneficial from the perspective of reducing wear debris generation, improving biocompatibility, and preventing failure during service. Fretting wear tests of Ni-Ti in both austenitic and martensitic microstructural conditions were performed with the goal of simulating wear which medical devices such as stents may experience during surgical implantation or service. The tests were performed using a stainless steel stylus counter-wearing surface under dry conditions and also with artificial plasma containing 80 g/L albumen protein as lubricant. Additionally, the research explores the feasibility of surface modification by sequential ion implantation with argon and oxygen to enhance the wear characteristics of the Ni-Ti alloy. Each of these implantations was performed to a dose of 3 x 10(17) atom/cm(2) and an energy of 50 kV, using the plasma source ion implantation process. Improvements in wear resistance were observed for the austenitic samples implanted with argon and oxygen. Ion implantation with argon also reduced the surface Ni content with respect to Ti due to differential sputtering rates of the two elements, an effect that points toward improved biocompatibility.

  4. Tribology and total hip joint replacement: current concepts in mechanical simulation.

    PubMed

    Affatato, S; Spinelli, M; Zavalloni, M; Mazzega-Fabbro, C; Viceconti, M

    2008-12-01

    Interest in the rheology and effects of interacting surfaces is as ancient as man. This subject can be represented by a recently coined word: tribology. This term is derived from the Greek word "tribos" and means the "science of rubbing". Friction, lubrication, and wear mechanism in the common English language means the precise field of interest of tribology. Wear of total hip prosthesis is a significant clinical problem that involves, nowadays, a too high a number of patients. In order to acquire further knowledge on the tribological phenomena that involve hip prosthesis wear tests are conducted on employed materials to extend lifetime of orthopaedic implants. The most basic type of test device is the material wear machine, however, a more advanced one may more accurately reproduce some of the in vivo conditions. Typically, these apparatus are called simulators, and, while there is no absolute definition of a joint simulator, its description as a mechanical rig used to test a joint replacement, under conditions approximating those occurring in the human body, is acceptable. Simulator tests, moreover, can be used to conduct accelerated protocols that replicate/simulate particularly extreme conditions, thus establishing the limits of performance for the material. Simulators vary in their level of sophistication and the international literature reveals many interpretations of the design of machines used for joint replacement testing. This paper aims to review the current state of the art of the hip joint simulators worldwide. This is specified through a schematic overview by describing, in particular, constructive solutions adopted to reproduce in vivo conditions. An exhaustive commentary on the evolution and actually existing simulation standards is proposed by the authors. The need of a shared protocol among research laboratories all over the world could lead to a consensus conference.

  5. Wear studies of all UHMWPE couples under various bio-tribological conditions.

    PubMed

    Joyce, T J; Unsworth, A

    2004-01-01

    Wear tests were undertaken in which ultra high molecular weight polyethylene (UHMWPE) was rubbed against itself. Tests primarily employed a pin-on-plate wear test machine, with distilled water, Ringer solution and dilute bovine serum being used as the lubricants. Loads of 10N and 40N were employed, and some test pins had a rotational motion added. In all cases wear was high, with mean wear factors of up to 91 10 -6 mm3/Nm being measured, but the addition of rotation reduced the amount of material worn from the test plates. In the presence of bovine serum and under reciprocation only, pin wear was relatively low. With bovine serum as the lubricant, total mean wear factors for the UHMWPE couples were calculated to be in the range of 35 to 58 10-6mm3/Nm. Therefore the pin-on-plate tests showed that the choice of lubricant as well as the motion applied to the test pin had a significant influence on the wear volumes measured. A two-piece UHMWPE 'prosthesis' with matching hemispherical faces was fabricated and tested on a finger simulator. Distilled water was used as the lubricant and wear factors were found to be greater for the metacarpal component, 21 10 -6mm3/Nm, than the phalangeal component, 3 10-6mm3/Nm, after ten million cycles of testing. This result paralleled the greater wear seen by the plate than by the pin in the pin-on-plate tests under reciprocating motion. (Journal of Applied Biomaterials & Biomechanics 2004; 2: 29-34).

  6. Accelerated degradation of polyetheretherketone and its composites in the deep sea

    PubMed Central

    Wang, Jianzhang; Jiang, Pengfei; Yan, Fengyuan

    2018-01-01

    The performance of polymer composites in seawater, under high hydrostatic pressure (typically few tens of MPa), for simulating exposures at great depths in seas and oceans, has been little studied. In this paper, polyetheretherketone (PEEK) and its composites reinforced by carbon fibres and glass fibres were prepared. The seawater environment with different seawater hydrostatic pressure ranging from normal pressure to 40 MPa was simulated with special equipment, in which the seawater absorption and wear behaviour of PEEK and PEEK-based composites were examined in situ. The effects of seawater hydrostatic pressure on the mechanical properties, wear resistance and microstructure of PEEK and its composites were focused on. The results showed that seawater absorption of PEEK and its composites were greatly accelerated by increased hydrostatic pressure in the deep sea. Affected by seawater absorption, both for neat PEEK and composites, the degradation on mechanical properties, wear resistance and crystallinity were induced, the degree of which was increasingly serious with the increase of hydrostatic pressure of seawater environment. There existed a good correlation in an identical form of exponential function between the wear rate and the seawater hydrostatic pressure. Moreover, the corresponding mechanisms of the effects of deep-sea hydrostatic pressure were also discussed. PMID:29765645

  7. Accelerated degradation of polyetheretherketone and its composites in the deep sea.

    PubMed

    Liu, Hao; Wang, Jianzhang; Jiang, Pengfei; Yan, Fengyuan

    2018-04-01

    The performance of polymer composites in seawater, under high hydrostatic pressure (typically few tens of MPa), for simulating exposures at great depths in seas and oceans, has been little studied. In this paper, polyetheretherketone (PEEK) and its composites reinforced by carbon fibres and glass fibres were prepared. The seawater environment with different seawater hydrostatic pressure ranging from normal pressure to 40 MPa was simulated with special equipment, in which the seawater absorption and wear behaviour of PEEK and PEEK-based composites were examined in situ . The effects of seawater hydrostatic pressure on the mechanical properties, wear resistance and microstructure of PEEK and its composites were focused on. The results showed that seawater absorption of PEEK and its composites were greatly accelerated by increased hydrostatic pressure in the deep sea. Affected by seawater absorption, both for neat PEEK and composites, the degradation on mechanical properties, wear resistance and crystallinity were induced, the degree of which was increasingly serious with the increase of hydrostatic pressure of seawater environment. There existed a good correlation in an identical form of exponential function between the wear rate and the seawater hydrostatic pressure. Moreover, the corresponding mechanisms of the effects of deep-sea hydrostatic pressure were also discussed.

  8. Abrasive wear of resin composites as related to finishing and polishing procedures.

    PubMed

    Turssi, Cecilia P; Ferracane, Jack L; Serra, Mônica C

    2005-07-01

    Finishing and polishing procedures may cause topographical changes and introduce subsurface microcracks in dental composite restoratives. Since both of these effects may contribute toward the kinetics of wear, the purpose of this study was to assess and correlate the wear and surface roughness of minifilled and nanofilled composites finished and polished by different methods. Specimens (n=10) made of a minifilled and a nanofilled composite were finished and polished with one of the four sequences: (1) tungsten carbide burs plus Al(2)O(3)-impregnated brush (CbBr) or (2) tungsten carbide burs plus diamond-impregnated cup (CbCp), (3) diamond burs plus brush (DmBr) or (4) diamond burs plus cup (DmCp). As a control, abrasive papers were used. After surface roughness had been quantified, three-body abrasion was simulated using the OHSU wear machine. The wear facets were then scanned to measure wear depth and post-testing roughness. All sets of data were subjected to ANOVA and Tukey's tests (alpha=0.05). Pearson's correlation test was applied to check for the existence of a relationship between pre-testing roughness and wear. Significantly smoother surfaces were attained with the sequences CbBr and CbCp, whereas DmCp yielded the roughest surface. Regardless of the finishing/polishing technique, the nanofilled composite exhibited the lowest pre-testing roughness and wear. There was no correlation between the surface roughness achieved after finishing/polishing procedures and wear (p=0.3899). Nano-sized materials may have improved abrasive wear resistance over minifilled composites. The absence of correlation between wear and surface roughness produced by different finishing/polishing methods suggests that the latter negligibly influences material loss due to three-body abrasion.

  9. Patterned CoCrMo and Al2 O3 surfaces for reduced free wear debris in artificial joint arthroplasty.

    PubMed

    Tarabolsi, Mohamad; Klassen, Thomas; Mantwill, Frank; Gärtner, Frank; Siegel, Frank; Schulz, Arndt-Peter

    2013-12-01

    Surface wear of corresponding tribological pairings is still a major problem in the application of artificial joint surgery. This study aims at developing wear reduced surfaces to utilize them in total joint arthroplasty. Using a pico-second laser, samples of medical CoCrMo metal alloy and Al2 O3 ceramic were patterned by laser material removal. The subsequent tribological investigations employed a ring-on-disc method. The results showed that those samples with modified surfaces show less mass or volume loss than those with a regular, smooth surface. Using calf serum as lubricating medium, the volume loss of the structured CoCrMo samples was eight times lower than that of regular samples. By structuring Al2 O3 surfaces, the wear volume could be reduced by 4.5 times. The results demonstrate that defined surface channels or pits enable the local sedimentation of wear debris. Thus, the amount of free debris could be reduced. Fewer abrasives in the lubricated so-called three-body-wear between the contact surfaces should result in less surface damage. Apart from direct influences on the wear behavior, less amounts of free debris of artificial joints should also be beneficial for avoiding undesired reactions with the surrounding soft tissues. The results from this study are very promising. Future investigations should involve the use of simulators meeting the natural conditions in the joint and in vivo studies with living organisms. Copyright © 2013 Wiley Periodicals, Inc., a Wiley Company.

  10. Wear of the Charité® lumbar intervertebral disc replacement investigated using an electro-mechanical spine simulator

    PubMed Central

    Moghadas, Parshia; Shepherd, Duncan ET; Hukins, David WL

    2015-01-01

    The Charité® lumbar intervertebral disc replacement was subjected to wear testing in an electro-mechanical spine simulator. Sinusoidally varying compression (0.6–2 kN, frequency 2 Hz), rotation (±2°, frequency 1 Hz), flexion–extension (6° to −3°, frequency 1 Hz) and lateral bending (±2°, frequency 1 Hz) were applied out of phase to specimens immersed in diluted calf serum at 37 °C. The mass of the ultra-high-molecular weight polyethylene component of the device was measured at intervals of 0.5, 1, 2, 3, 4 and 5 million cycles; its volume was also measured by micro-computed tomography. Total mass and volume losses were 60.3 ± 4.6 mg (mean ± standard deviation) and 64.6 ± 6.0 mm3. Corresponding wear rates were 12.0 ± 1.4 mg per million cycles and 12.8 ± 1.2 mm3 per million cycles; the rate of loss of volume corresponds to a mass loss of 11.9 ± 1.1 mg per million cycles, that is, the two sets of measurements of wear agree closely. Wear rates also agree closely with measurements made in another laboratory using the same protocol but using a conventional mechanical spine simulator. PMID:25834002

  11. Simultaneous measurement of friction and wear in hip simulators.

    PubMed

    Haider, Hani; Weisenburger, Joel N; Garvin, Kevin L

    2016-05-01

    We propose and have evaluated a method to measure hip friction during wear testing on a popular multi-station hip simulator. A 6-degree-of-freedom load cell underneath the specimen sensed forces and torques during implant wear testing of simulated walking. This included internal-external and adduction-abduction rotations which are often neglected during friction testing on pendulum-type machines. Robust mathematical analysis and data processing provided friction estimates in three simultaneous orthogonal rotations, over extended multi-million cycle wear tests. We tested various bearing couples including metal-on-plastic, ceramic-on-plastic, and metal-on-metal material couples. In one test series, new and intentionally scratched CoCrMo 40-mm-diameter femoral heads were tested against conventional ultrahigh-molecular-weight polyethylene, highly cross-linked, and highly cross-linked with vitamin E versions. The scratching significantly increased friction and doubled the wear of all groups. Before scratching, friction levels for the aforementioned plastic groups were 0.056 ± 0.0060, 0.062 ± 0.0080, and 0.070 ± 0.0045, respectively, but after scratching increased to 0.088 ± 0.018, 0.076 ± 0.0066, and 0.082 ± 0.0049, respectively, all statistically significant increases (p = 0.00059, 0.00005, 0.0115, respectively). In another test series of 44-mm femoral head diameter hips, metal-on-plastic hips with conventional ultrahigh-molecular-weight polyethylene showed the lowest friction at 0.045 ± 0.0085, followed by highly cross-linked with 0.046 ± 0.0035 (not significantly different). In a ceramic-on-plastic design with conventional ultrahigh-molecular-weight polyethylene, higher friction 0.079 ± 0.0070 was measured likely due to that ceramic surface being rougher than usual. Metal-on-metal hips were compared without and with a TiN coating, resulting in 0.049 ± 0.014 and 0.097 ± 0.020 friction factors, respectively (statistically significant, p < 0.001), and the coating wore away on all coated hips eventually. Higher friction mostly correlated with higher wear or damage to femoral heads or implant coatings, except for the highly cross-linked wear resistant ultrahigh-molecular-weight polyethylene which had slightly higher friction, confirming the same finding in other independent studies. This type of friction measurements can help screen for clamping and elevated wear of metal-on-metal and resurfacing total hip replacements, surgical malpositioning, and abraded and otherwise damaged surfaces. © IMechE 2016.

  12. Biomechanical properties of polymer-infiltrated ceramic crowns on one-piece zirconia implants after long-term chewing simulation.

    PubMed

    Baumgart, Pia; Kirsten, Holger; Haak, Rainer; Olms, Constanze

    2018-05-23

    Implant and superstructure provide a complex system, which has to withstand oral conditions. Concerning the brittleness of many ceramics, fractures are a greatly feared issue. Therefore, polymer-infiltrated ceramic networks (PICNs) were developed. Because of its low Young's modulus and high elastic modulus, the PICN crown on a one-piece zirconia implant might absorb forces to prevent the system from fracturing in order to sustain oral forces. Recommendations for the material of superstructure on zirconia implants are lacking, and only one study investigates PICN crowns on these types of implants. Accordingly, this study aimed to examine PICN crowns on one-piece zirconia implants regarding bond strength and surface wear after long-term chewing simulation (CS). Twenty-five hybrid ceramic crowns (Vita Enamic, Vita Zahnfabrik) were produced using computer-aided design/computer-aided manufacturing (CAD/CAM) technology and adhesively bonded (RelyX™ Ultimate, 3M ESPE) to zirconia implants. Twenty of the specimens underwent simultaneous mechanical loading and thermocycling simulating a 5-year clinical situation (SD Mechatronik GmbH). Wear depth and wear volume, based on X-ray micro-computed tomography volume scans (Skyscan 1172-100-50, Bruker) before and after CS, were evaluated. All crowns were removed from the implants using a universal testing machine (Z010, Zwick GmbH&Co.KG). Subsequently, luting agent was light microscopically localized (Stemi 2000-C, Zeiss). With a scanning electron microscope (SEM, Phenom™ G2 pro, Phenom World), the area of abrasion was assessed. 1. After CS, none of the tested crowns were fractured or loosened. 2. The maximum vertical wear after CS was M = 0.31 ± 0.04 mm (mean ± standard deviation), and the surface wear was M = 0.74 ± 0.23 mm 3 . 3. The pull-off tests revealed a 1.8 times higher bond strength of the control group compared to the experimental group (t(23) = 8.69, p < 0.001). 4. Luting agent was mostly located in the crowns, not on the implants. 5. The area of abrasion showed avulsion and a rough surface. PICN on one-piece zirconia implants showed high bond strength and high wear after CS.

  13. Estimation of tool wear compensation during micro-electro-discharge machining of silicon using process simulation

    NASA Astrophysics Data System (ADS)

    Muralidhara, .; Vasa, Nilesh J.; Singaperumal, M.

    2010-02-01

    A micro-electro-discharge machine (Micro EDM) was developed incorporating a piezoactuated direct drive tool feed mechanism for micromachining of Silicon using a copper tool. Tool and workpiece materials are removed during Micro EDM process which demand for a tool wear compensation technique to reach the specified depth of machining on the workpiece. An in-situ axial tool wear and machining depth measurement system is developed to investigate axial wear ratio variations with machining depth. Stepwise micromachining experiments on silicon wafer were performed to investigate the variations in the silicon removal and tool wear depths with increase in tool feed. Based on these experimental data, a tool wear compensation method is proposed to reach the desired depth of micromachining on silicon using copper tool. Micromachining experiments are performed with the proposed tool wear compensation method and a maximum workpiece machining depth variation of 6% was observed.

  14. Effect of power toothbrushing on simulated wear of dental cement margins.

    PubMed

    Black, Marsha A; Bayne, Stephen C; Peterson, Charlotte A

    2007-01-01

    Power toothbrushes (PTBs), in combination with abrasive dentifrices, may encourage wear of dental cements at crown margins. The objective of this in vitro simulation was to control the clinical variables associated with PTB use and measure the potential side effects of PTBs with mild and abrasive dentifrices. Four PTBs ( Braun-Oral-B-Professional Care at 150 g brushing force, Sonicare-Elite at 90 g, Colgate-Actibrush at 200 g and Crest-Spinbrush-Pro at 250 g) and 2 dentifrices mixed 1:1 with tap water (Mild= Colgate-Total, Colgate-Palmolive; Abrasive= Close-up, Chesebrough-Ponds) versus tap water alone (control) were used to abrade 2 cements (Fleck's Mizzy Zinc Phosphate [ZP]; 3M-ESPE Unicem universal cement [UC]) using cement-filled slots (160 m wide) cut into wear-resistant ceramic blocks. A custom fixture controlled PTB/block alignment, PTB loads, and other testing variables. Wear was measured (3 profilometer traces/slot, 5 slots/block/group, baseline to 5-year differences) and analyzed (3-way ANOVA, p < or = 0.05, Bonferroni). Wear for ZP was much greater than UC (p<0.05) for all 4 PTBs and both dentifrices. Brushing with water showed no effects (p<0.05). Cement-PTB-dentifrice interactions did occur. Only minor differences occurred among PTBs. Pooled 5y-wear levels for ZP for both dentifrices approximately 21 microm /5y) were similar to values for current-day posterior composite materials. Combinations of PTBs with mild and abrasive dentifrices produced significant wear with ZP but not UC; thus, resin-composite cements seem to represent a better choice for wear resistance.

  15. Wear characteristics of current aesthetic dental restorative CAD/CAM materials: two-body wear, gloss retention, roughness and Martens hardness.

    PubMed

    Mörmann, Werner H; Stawarczyk, Bogna; Ender, Andreas; Sener, Beatrice; Attin, Thomas; Mehl, Albert

    2013-04-01

    This study determined the two-body wear and toothbrushing wear parameters, including gloss and roughness measurements and additionally Martens hardness, of nine aesthetic CAD/CAM materials, one direct resin-based nanocomposite plus that of human enamel as a control group. Two-body wear was investigated in a computer-controlled chewing simulator (1.2 million loadings, 49N at 1.7Hz; 3000 thermocycles 5/50°C). Each of the 11 groups consisted of 12 specimens and 12 enamel antagonists. Quantitative analysis of wear was carried out with a 3D-surface analyser. Gloss and roughness measurements were evaluated using a glossmeter and an inductive surface profilometer before and after abrasive toothbrushing of machine-polished specimens. Additionally Martens hardness was measured. Statistically significant differences were calculated with one-way ANOVA (analysis of variance). Statistically significant differences were found for two-body wear, gloss, surface roughness and hardness. Zirconium dioxide ceramics showed no material wear and low wear of the enamel antagonist. Two-body wear of CAD/CAM-silicate and -lithium disilicate ceramics, -hybrid ceramics and -nanocomposite as well as direct nanocomposite did not differ significantly from that of human enamel. Temporary polymers showed significantly higher material wear than permanent materials. Abrasive toothbrushing significantly reduced gloss and increased roughness of all materials except zirconium dioxide ceramics. Gloss retention was highest with zirconium dioxide ceramics, silicate ceramics, hybrid ceramics and nanocomposites. Temporary polymers showed least gloss retention. Martens hardness differed significantly among ceramics, between ceramics and composites, and between resin composites and acrylic block materials as well. All permanent aesthetic CAD/CAM block materials tested behave similarly or better with respect to two-body wear and toothbrushing wear than human enamel, which is not true for temporary polymer CAD/CAM block materials. Ceramics show the best gloss retention compared to hybrid ceramics, composites and acrylic polymers. Copyright © 2013 Elsevier Ltd. All rights reserved.

  16. Tribological assessment of a flexible carbon-fibre-reinforced poly(ether-ether-ketone) acetabular cup articulating against an alumina femoral head.

    PubMed

    Scholes, S C; Inman, I A; Unsworth, A; Jones, E

    2008-04-01

    New material combinations have been introduced as the bearing surfaces of hip prostheses in an attempt to prolong their life by overcoming the problems of failure due to wear-particle-induced osteolysis. This will hopefully reduce the need for revision surgery. The study detailed here used a hip simulator to assess the volumetric wear rates of large-diameter carbon-fibre-reinforced pitch-based poly(ether-ether-ketone) (CFR-PEEK) acetabular cups articulating against alumina femoral heads. The joints were tested for 25 x 10(6) cycles. Friction tests were also performed on these joints to determine the lubrication regime under which they operate. The average volumetric wear rate of the CFR-PEEK acetabular component of 54 mm diameter was 1.16 mm(3)/10(6) cycles, compared with 38.6 mm(3)/10(6) cycles for an ultra-high-molecular-weight polyethylene acetabular component of 28 mm diameter worn against a ceramic head. This extremely low wear rate was sustained over 25 x 10(6) cycles (the equivalent of up to approximately 25 years in vivo). The frictional studies showed that the joints worked under the mixed-boundary lubrication regime. The low wear produced by these joints showed that this novel joint couple offers low wear rates and therefore may be an alternative material choice for the reduction of osteolysis.

  17. Characterization of ion beam modified ceramic wear surfaces using Auger electron spectroscopy

    NASA Technical Reports Server (NTRS)

    Wei, W.; Lankford, J.

    1987-01-01

    An investigation of the surface chemistry and morphology of the wear surfaces of ceramic material surfaces modified by ion beam mixing has been conducted using Auger electron spectroscopy and secondary electron microscopy. Studies have been conducted on ceramic/ceramic friction and wear couples made up of TiC and NiMo-bonded TiC cermet pins run against Si3N4 and partially stabilized zirconia disc surfaces modified by the ion beam mixing of titanium and nickel, as well as ummodified ceramic/ceramic couples in order to determine the types of surface changes leading to the improved friction and wear behavior of the surface modified ceramics in simulated diesel environments. The results of the surface analyses indicate that the formation of a lubricating oxide layer of titanium and nickel, is responsible for the improvement in ceramic friction and wear behavior. The beneficial effect of this oxide layer depends on several factors, including the adherence of the surface modified layer or subsequently formed oxide layer to the disc substrate, the substrate materials, the conditions of ion beam mixing, and the environmental conditions.

  18. How can the pressure in anti-embolism stockings be maintained during use? Laboratory evaluation of simulated 'wear' and different reconditioning protocols.

    PubMed

    Macintyre, Lisa; Stewart, Hazel; Rae, Michelle

    2016-12-01

    Deep vein thrombosis is a major global health issue, responsible for thousands of deaths each year. While thrombi can form under a variety of circumstances, lack of mobility significantly increases risk and therefore non-ambulant patients are frequently fitted with anti-embolism stockings on admission to hospital, to aid blood flow, prevent pooling and thus clotting. Anti-embolism stockings are the most widely used non-invasive medical device on the market and are believed to reduce the risk of deep vein thrombosis by 40%. Despite their widespread use in hospitals world-wide, there is remarkably little research addressing their use or reconditioning and a wide variety of different reconditioning protocols are used in hospitals. The objective of this study was to establish the impact of different wear and reconditioning protocols on the pressure delivering ability of anti-embolism stockings. A laboratory investigation was undertaken to evaluate the pressure delivering ability of 2 major global brands of anti-embolism stockings over 5-8days of simulated wear (extension on static cylinders) and 4 different reconditioning protocols. 1 set of samples was continuously 'worn' for 8days without reconditioning, 1 set of samples was 'worn' for 5days with a day of relaxation between each day of 'wear', 1 set was 'hand washed' and 1 set was machine washed and then allowed to relax between each day of 'wear'. The pressure was measured at the beginning and end of each period of 'wear'. This study was undertaken in a conditioned textile testing laboratory that complies with BS EN ISO 139:2005+A1:2011. The pressure exerted by anti-embolism stockings reduced by between 15 and 24% after 24h of wear, it reduced by between 21 and 32% when worn continuously for 8days. Allowing stockings to rest for a day between days of wear allowed them to recover slightly but this recovery was only temporary. Washing stockings regenerated their pressure delivering potential significantly and machine washing allowed some to recover to exert more pressure than they had when new. Different brands of anti-embolism stockings exert different pressures on the same size of leg, when correctly fitted. The pressure exerted by anti-embolism stockings decreases with use but the correct pressure gradient is maintained if correctly fitted. Washing stockings after 24h of wear is effective in restoring their pressure delivering abilities and in some cases can surpass their 'as new' pressure delivering ability. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Tribological measurements on a Charnley-type artificial hip joint

    NASA Technical Reports Server (NTRS)

    Jones, W. R., Jr.

    1983-01-01

    A total hip simulator was used to determine the friction and wear properties of Charnley-type (316L stainless steel balls and sterile ultrahigh molecular weight polyethylene cups) hip prostheses. Three different sets of specimens were tested to 395,000, 101,500 and 233,000 walking cycles, respectively. All tests were run unlubricated, at ambient conditions (22 to 26 C, 30 to 50 percent relative humidity), at 30 walking cycles per minute, under a dynamic load simulating walking. Polyethylene cup wear rates ranged from 1.4 to 39 ten billions cu m which corresponds to dimensional losses of 4.0 to 11 microns per year. Although these wear rates are lower than those obtained from other hip simulators and from in vivo X-ray measurements, they are comparable when taking run-in and plastic deformation into account. Maximum tangential friction forces ranged from 93 to 129 N under variable load (267 to 3090 N range) and from 93 to 143 N under a static load of 3090 N. A portion of one test 250,000 walking cycles) run under dry air ( 1 percent relative humidity) yielded a wear rate almost 6 times greater than that obtained under wet air ( 70 percent relative humidity) conditions.

  20. [Surface roughness and gloss of novel flowable composites after polishing and simulated brushing wear].

    PubMed

    Wang, R L; Yuan, C Y; Pan, Y X; Tian, F C; Wang, Z H; Wang, X Y

    2017-04-09

    Objective: To investigate surface properties of novel flowable composites after polishing and simulated brushing wear, compared to their pasty counterpart. Methods: Composites employed in this study were: three flowable composites (A1: Clearfil Majesty ES Flow; B1: Beautifil Flow Plus F00; C1: Filtek Bulk Fill) and three paste composites (A2: Clearfil Majesty; B2: Beautifil; C2: Filtek Z350. Eleven disk-shaped specimens were made for each material. The specimens were cured, then subjected to sandpaper finishing for 20 s, one-step polishing for 30 s, finally subjected to simulated brushing for 10 000 cycles. Surface roughness and glossiness were measured before finishing, after finishing, after polishing, after 5 000 brushing cycles and after 10 000 brushing cycles, respectively. Data obtained were analyzed using two-way ANOVA method. Scanning electron microscope was employed to examine the microscopic appearance of each material. Results: Surface roughness (0.11~0.22 μm) and glossiness (74.25~86.48 GU) of each material were similar after one-step polishing. After brushing simulation, roughness increased significantly and glossiness decreased significantly for each material ( P< 0.05). Group A1 presented the best gloss ([50.68±1.58] GU) after final wear ( P< 0.05). Flowable composites of group A1 and B1 tested in the present setup showed better surface properties compared to their pasty counterpart (group A2 and B2). Conclusions: Within the limit of this study, flowable composites tested in the present research can obtain similar surface polish or even better than the paste composite counterpart.

  1. Development of friction and wear full-scale testing for TKR prostheses with reliable low cost apparatus

    NASA Astrophysics Data System (ADS)

    Suwandi, Agri; Soemardi, Tresna P.; Kiswanto, Gandjar; Kusumaningsih, Widjajalaksmi; I. Gusti Agung I. G., W.

    2018-02-01

    Prostheses products must undergo simulation and physical testing, before clinical testing. Finite element method is a preliminary simulation for in vivo test. The method visualizes the magnitude of the compressive force and the critical location of the Total Knee Replacement (TKR) prostheses design. In vitro testing is classified as physical testing for prostheses product. The test is conducted to evaluate the potential failure of the product and the characteristics of the prostheses TKR material. Friction and wear testing are part of the in vivo test. Motion of knee joints, which results in the phenomena of extension and deflection in the femoral and tibia insert, is represented by friction and wear testing. Friction and wear tests aim to obtain an approximate lifetime in normal and extreme load patterns as characterized by the shape of the friction surface area. The lifetime estimation requires friction and wear full-scale testing equipments for TKR prostheses products. These are necessary in obtaining initial data on potential product failures and characterizing of the material based on the ASTM F2724-08 standards. Based on the testing result and statistical analysis data, the average wear rate value per year is 2.19 × 10-3 mg/MC, with a 10 % safety limit of volume and 14,400 cycles times, for 15 hours moving nonstop then the prediction of wear life of the component tibia insert is ± 10 years.

  2. Wear studies on plasma-sprayed Al2O3 and 8mole% of Yttrium-stabilized ZrO2 composite coating on biomedical Ti-6Al-4V alloy for orthopedic joint application

    PubMed Central

    Ganapathy, Perumal; Manivasagam, Geetha; Rajamanickam, Asokamani; Natarajan, Alagumurthi

    2015-01-01

    This paper presents the wear characteristics of the composite ceramic coating made with Al2O3-40wt%8YSZ on the biomedical grade Ti-6Al-4V alloy (grade 5) used for total joint prosthetic components, with the aim of improving their tribological behavior. The coatings were deposited using a plasma spraying technique, and optimization of plasma parameters was performed using response surface methodology to obtain dense coating. The tribological behaviors of the coated and uncoated substrates were evaluated using a ball-on-plate sliding wear tester at 37°C in simulated body-fluid conditions. The microstructure of both the titanium alloy and coated specimen were examined using an optical microscope and scanning electron microscope. The hardness of the plasma-sprayed alumina–zirconia composite coatings was 2.5 times higher than that of the Ti-6Al-4V alloy, while the wear rate of Ti-6Al-4V alloy was 253 times higher than that of the composite-coated Ti-6Al-4V alloy. The superior wear resistance of the alumina–zirconia coated alloy is attributed to its enhanced hardness and intersplat bonding strength. Wear-track examination showed that the predominant wear mechanism of Ti-6Al-4V alloy was abrasive and adhesive wear, whereas, in the case of alumina–zirconia composite coated alloy, the wear was dominated by microchipping and microcracking. PMID:26491323

  3. The effect of CPP-ACP on enamel wear under severe erosive conditions.

    PubMed

    Ranjitkar, Sarbin; Kaidonis, John A; Richards, Lindsay C; Townsend, Grant C

    2009-06-01

    In addition to its role as a remineralizing agent in preventing dental caries, recent evidence has shown that casein phosphopeptide-amorphous calcium phosphate (CPP-ACP) can protect teeth against erosion. The aim of this study was to determine whether CPP-ACP could reduce enamel wear rates under severe erosive conditions simulating heavy attrition and gastric regurgitation. Enamel specimens were subjected to 10,000 wear cycles at a load of 100 N and pH 1.2 in a tooth wear machine. The machine was stopped every 2 min (160 cycles), and CPP-ACP in the form of a paste was applied for 5 min in experimental group 1. A paste with the same formulation but without CPP-ACP was applied in experimental group 2. No paste was applied in the control group. A linear mixed model analysis indicated that the mean wear rates in experimental group 1 (0.44+/-0.05 mm(3) per 1000 cycles) and in experimental group 2 (0.63+/-0.06 mm(3) per 1000 cycles) were significantly lower than that in the control group (0.92+/-0.11 mm(3) per 1000 cycles) (p<0.05). The mean wear rate in experimental group 1 was also lower than that in experimental group 2 (p<0.05). Wear facets in experimental groups 1 and 2 were noted to be smoother and more polished than those in the control group. Both remineralizing and lubricating properties of the paste containing CPP-ACP appear to contribute to wear reduction in enamel. These findings may lead to new strategies for the clinical management of tooth wear.

  4. The John Charnley Award: an accurate and sensitive method to separate, display, and characterize wear debris: part 1: polyethylene particles.

    PubMed

    Billi, Fabrizio; Benya, Paul; Kavanaugh, Aaron; Adams, John; Ebramzadeh, Edward; McKellop, Harry

    2012-02-01

    Numerous studies indicate highly crosslinked polyethylenes reduce the wear debris volume generated by hip arthroplasty acetabular liners. This, in turns, requires new methods to isolate and characterize them. We describe a method for extracting polyethylene wear particles from bovine serum typically used in wear tests and for characterizing their size, distribution, and morphology. Serum proteins were completely digested using an optimized enzymatic digestion method that prevented the loss of the smallest particles and minimized their clumping. Density-gradient ultracentrifugation was designed to remove contaminants and recover the particles without filtration, depositing them directly onto a silicon wafer. This provided uniform distribution of the particles and high contrast against the background, facilitating accurate, automated, morphometric image analysis. The accuracy and precision of the new protocol were assessed by recovering and characterizing particles from wear tests of three types of polyethylene acetabular cups (no crosslinking and 5 Mrads and 7.5 Mrads of gamma irradiation crosslinking). The new method demonstrated important differences in the particle size distributions and morphologic parameters among the three types of polyethylene that could not be detected using prior isolation methods. The new protocol overcomes a number of limitations, such as loss of nanometer-sized particles and artifactual clumping, among others. The analysis of polyethylene wear particles produced in joint simulator wear tests of prosthetic joints is a key tool to identify the wear mechanisms that produce the particles and predict and evaluate their effects on periprosthetic tissues.

  5. Advances in tribological testing of artificial joint biomaterials using multidirectional pin-on-disk testers

    PubMed Central

    Baykal, D.; Siskey, R.S.; Haider, H.; Saikko, V.; Ahlroos, T.; Kurtz, S.M.

    2013-01-01

    The introduction of numerous formulations of Ultra-high molecular weight polyethylene (UHMWPE), which is widely used as a bearing material in orthopedic implants, necessitated screening of bearing couples to identify promising iterations for expensive joint simulations. Pin-on-disk (POD) testers capable of multidirectional sliding can correctly rank formulations of UHMWPE with respect to their predictive in vivo wear behavior. However, there are still uncertainties regarding POD test parameters for facilitating clinically relevant wear mechanisms of UHMWPE. Studies on the development of POD testing were briefly summarized. We systematically reviewed wear rate data of UHMWPE generated by POD testers. To determine if POD testing was capable of correctly ranking bearings and if test parameters outlined in ASTM F732 enabled differentiation between wear behavior of various formulations, mean wear rates of non-irradiated, conventional (25–50 kGy) and highly crosslinked (≥90 kGy) UHMWPE were grouped and compared. The mean wear rates of non-irradiated, conventional and highly crosslinked UHMWPEs were 7.03, 5.39 and 0.67 mm3/MC. Based on studies that complied with the guidelines of ASTM F732, the mean wear rates of non-irradiated, conventional and highly crosslinked UHMWPEs were 0.32, 0.21 and 0.04 mm3/km, respectively. In both sets of results, the mean wear rate of highly crosslinked UHMPWE was smaller than both conventional and non-irradiated UHMWPEs (p<0.05). Thus, POD testers can compare highly crosslinked and conventional UHMWPEs despite different test parameters. Narrowing the allowable range for standardized test parameters could improve sensitivity of multi-axial testers in correctly ranking materials. PMID:23831149

  6. Deformation effect simulation and optimization for double front axle steering mechanism

    NASA Astrophysics Data System (ADS)

    Wu, Jungang; Zhang, Siqin; Yang, Qinglong

    2013-03-01

    This paper research on tire wear problem of heavy vehicles with Double Front Axle Steering Mechanism from the flexible effect of Steering Mechanism, and proposes a structural optimization method which use both traditional static structural theory and dynamic structure theory - Equivalent Static Load (ESL) method to optimize key parts. The good simulated and test results show this method has high engineering practice and reference value for tire wear problem of Double Front Axle Steering Mechanism design.

  7. Effect of wear of bearing surfaces on elastohydrodynamic lubrication of metal-on-metal hip implants.

    PubMed

    Liu, F; Jin, Z M; Hirt, F; Rieker, C; Roberts, P; Grigoris, P

    2005-09-01

    The effect of geometry change of the bearing surfaces owing to wear on the elastohydrodynamic lubrication (EHL) of metal-on-metal (MOM) hip bearings has been investigated theoretically in the present study. A particular MOM Metasul bearing (Zimmer GmbH) was considered, and was tested in a hip simulator using diluted bovine serum. The geometry of the worn bearing surface was measured using a coordinate measuring machine (CMM) and was modelled theoretically on the assumption of spherical geometries determined from the maximum linear wear depth and the angle of the worn region. Both the CMM measurement and the theoretical calculation were directly incorporated into the elastohydrodynamic lubrication analysis. It was found that the geometry of the original machined bearing surfaces, particularly of the femoral head with its out-of-roundness, could lead to a large reduction in the predicted lubricant film thickness and an increase in pressure. However, these non-spherical deviations can be expected to be smoothed out quickly during the initial running-in period. For a given worn bearing surface, the predicted lubricant film thickness and pressure distribution, based on CMM measurement, were found to be in good overall agreement with those obtained with the theoretical model based on the maximum linear wear depth and the angle of the worn region. The gradual increase in linear wear during the running-in period resulted in an improvement in the conformity and consequently an increase in the predicted lubricant film thickness and a decrease in the pressure. For the Metasul bearing tested in an AMTI hip simulator, a maximum total linear wear depth of approximately 13 microm was measured after 1 million cycles and remained unchanged up to 5 million cycles. This resulted in a threefold increase in the predicted average lubricant film thickness. Consequently, it was possible for the Metasul bearing to achieve a fluid film lubrication regime during this period, and this was consistent with the minimal wear observed between 1 and 5 million cycles. However, under adverse in vivo conditions associated with start-up and stopping and depleted lubrication, wear of the bearing surfaces can still occur. An increase in the wear depth beyond a certain limit was shown to lead to the constriction of the lubricant film around the edge of the contact conjunction and consequently to a decrease in the lubricant film thickness. Continuous cycles of a running-in wear period followed by a steady state wear period may be inevitable in MOM hip implants. This highlights the importance of minimizing the wear in these devices during the initial running-in period, particularly from design and manufacturing points of view.

  8. Lunar Dust Simulant in Mechanical Component Testing - Paradigm and Practicality

    NASA Technical Reports Server (NTRS)

    Jett, T.; Street, K.; Abel, P.; Richmond, R.

    2008-01-01

    Due to the uniquely harsh lunar surface environment, terrestrial test activities may not adequately represent abrasive wear by lunar dust likely to be experienced in mechanical systems used in lunar exploration. Testing to identify potential moving mechanism problems has recently begun within the NASA Engineering and Safety Center Mechanical Systems Lunar Dust Assessment activity in coordination with the Exploration Technology and Development Program Dust Management Project, and these complimentary efforts will be described. Specific concerns about differences between simulant and lunar dust, and procedures for mechanical component testing with lunar simulant will be considered. In preparing for long term operations within a dusty lunar environment, the three fundamental approaches to keeping mechanical equipment functioning are dust avoidance, dust removal, and dust tolerance, with some combination of the three likely to be found in most engineering designs. Methods to exclude dust from contact with mechanical components would constitute mitigation by dust avoidance, so testing seals for dust exclusion efficacy as a function of particle size provides useful information for mechanism design. Dust of particle size less than a micron is not well documented for impact on lunar mechanical components. Therefore, creating a standardized lunar dust simulant in the particulate size range of ca. 0.1 to 1.0 micrometer is useful for testing effects on mechanical components such as bearings, gears, seals, bushings, and other moving mechanical assemblies. Approaching actual wear testing of mechanical components, it is beneficial to first establish relative wear rates caused by dust on commonly used mechanical component materials. The wear mode due to dust within mechanical components, such as abrasion caused by dust in grease(s), needs to be considered, as well as the effects of vacuum, lunar thermal cycle, and electrostatics on wear rate.

  9. Tribological investigation of novel HDPE-HAp-Al2O3 hybrid biocomposites against steel under dry and simulated body fluid condition.

    PubMed

    Nath, Shekhar; Bodhak, Subhadip; Basu, Bikramjit

    2007-10-01

    Among various biocompatible polymers, polyethylene based materials have received wider attention because of its excellent stability in body fluid, inertness, and easy formability. Attempts have been made to improve their physical properties (modulus/strength) to enable them to be used as load bearing hard tissue replacement applications. Among such attempts, high density polyethylene (HDPE)-hydroxyapatite (HAp) composite (HAPEX), has already been developed for total hip replacement (THR) acetabular cup and low load bearing bone tissue replacement. In the present work, alumina has been added as a partial replacement of HAp phase to improve the mechanical and tribological properties of the HAPEX composite. In an attempt to assess the suitability of the developed composite in THR application, the tribological properties against steel counterbody under both in air and simulated body fluid (SBF), have been investigated and efforts have been made to understand the wear mechanisms. The fretting wear study indicates the possibility of achieving extremely low COF (Coefficient of Friction approximately 0.09) as well as higher wear resistance (order of 10(-6) mm(3)/N m) with the newly developed composites in SBF. A low wear depth of approximately 4.6-5.3 microm is recorded, irrespective of fretting environment. The implication of the work is that optimal and combined addition of bioactive and bioinert ceramic filler to HDPE can provide a good opportunity to obtain hybrid biocomposites with better combination of physical properties (modulus, hardness) as well as low friction and high wear resistance.

  10. Friction and wear of carbon-graphite materials for high-energy brakes

    NASA Technical Reports Server (NTRS)

    Bill, R. C.

    1978-01-01

    Caliper type brake simulation experiments were conducted on seven different carbon graphite materials formulations against a steel disk material and against a carbon graphite disk material. The effects of binder level, boron carbide (B4C) additions, SiC additions, graphite fiber additions, and graphite cloth reinforcement on friction and wear behavior were investigated. Reductions in binder level, additions of B4C, and additions of SiC each resulted in increased wear. The wear rate was not affected by the addition of graphite fibers. Transition to severe wear and high friction was observed in the case of graphite-cloth-reinforced carbon sliding against a disk of similar composition. The transition was related to the disruption of a continuous graphite shear film that must form on the sliding surfaces if low wear is to occur.

  11. Wear properties of dental ceramics and porcelains compared with human enamel.

    PubMed

    D'Arcangelo, Camillo; Vanini, Lorenzo; Rondoni, Giuseppe D; De Angelis, Francesco

    2016-03-01

    Contemporary pressable and computer-aided design/manufacturing (CAD/CAM) ceramics exhibit good mechanical and esthetic properties. Their wear resistance compared with human enamel and traditional gold based alloys needs to be better investigated. The purpose of this in vitro study was to compare the 2-body wear resistance of human enamel, gold alloy, and 5 different dental ceramics, including a recently introduced zirconia-reinforced lithium silicate ceramic (Celtra Duo). Cylindrical specimens were fabricated from a Type III gold alloy (Aurocast8), 2 hot pressed ceramics (Imagine PressX, IPS e.max Press), 2 CAD/CAM ceramics (IPS e.max CAD, Celtra Duo), and a CAD/CAM feldspathic porcelain (Vitablocs Mark II) (n=10). Celtra Duo was tested both soon after grinding and after a subsequent glaze firing cycle. Ten flat human enamel specimens were used as the control group. All specimens were subjected to a 2-body wear test in a dual axis mastication simulator for 120000 loading cycles against yttria stabilized tetragonal zirconia polycrystal cusps. The wear resistance was analyzed by measuring the vertical substance loss (mm) and the volume loss (mm(3)). Antagonist wear (mm) was also recorded. Data were statistically analyzed with 1-way ANOVA tests (α=.05). The wear depth (0.223 mm) of gold alloy was the closest to that of human enamel (0.217 mm), with no significant difference (P>.05). The greatest wear was recorded on the milled Celtra Duo (wear depth=0.320 mm), which appeared significantly less wear resistant than gold alloy or human enamel (P<.05). The milled and not glazed Celtra Duo showed a small but significantly increased wear depth compared with Aurocast8 and human enamel. Wear depth and volumetric loss for the glaze-fired Celtra Duo and for the other tested ceramics did not statistically differ in comparison with the human enamel. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  12. Orbital transfer rocket engine technology program: Soft wear ring seal technology

    NASA Technical Reports Server (NTRS)

    Lariviere, Brian W.

    1992-01-01

    Liquid oxygen (LOX) compatibility tests, including autogenous ignition, promoted ignition, LOX impact tests, and friction and wear tests on different PV products were conducted for several polymer materials as verification for the implementation of soft wear ring seals in advanced rocket engine turbopumps. Thermoplastics, polyimide based materials, and polyimide-imide base materials were compared for oxygen compatibility, specific wear coefficient, wear debris production, and heat dissipation mechanisms. A thermal model was generated that simulated the frictional heating input and calculated the surface temperature and temperature distribution within the seal. The predictions were compared against measured values. Heat loads in the model were varied to better match the test data and determine the difference between the measured and the calculated coefficients of friction.

  13. Atomic insight into tribochemical wear mechanism of silicon at the Si/SiO2 interface in aqueous environment: Molecular dynamics simulations using ReaxFF reactive force field

    NASA Astrophysics Data System (ADS)

    Wen, Jialin; Ma, Tianbao; Zhang, Weiwei; Psofogiannakis, George; van Duin, Adri C. T.; Chen, Lei; Qian, Linmao; Hu, Yuanzhong; Lu, Xinchun

    2016-12-01

    In this work, the atomic mechanism of tribochemical wear of silicon at the Si/SiO2 interface in aqueous environment was investigated using ReaxFF molecular dynamics (MD) simulations. Two types of Si atom removal pathways were detected in the wear process. The first is caused by the destruction of stretched Si-O-Si bonds on the Si substrate surface and is assisted by the attachment of H atoms on the bridging oxygen atoms of the bonds. The other is caused by the rupture of Si-Si bonds in the stretched Si-Si-O-Si bond chains at the interface. Both pathways effectively remove Si atoms from the silicon surface via interfacial Si-O-Si bridge bonds. Our simulations also demonstrate that higher pressures applied to the silica phase can cause more Si atoms to be removed due to the formation of increased numbers of interfacial Si-O-Si bridge bonds. Besides, water plays a dual role in the wear mechanism, by oxidizing the Si substrate surface as well as by preventing the close contact of the surfaces. This work shows that the removal of Si atoms from the substrate is a result of both chemical reaction and mechanical effects and contributes to the understanding of tribochemical wear behavior in the microelectromechanical systems (MEMS) and Si chemical mechanical polishing (CMP) process.

  14. Using a surrogate contact pair to evaluate polyethylene wear in prosthetic knee joints.

    PubMed

    Sanders, Anthony P; Lockard, Carly A; Weisenburger, Joel N; Haider, Hani; Raeymaekers, Bart

    2016-01-01

    With recent improvements to the properties of ultra-high molecular weight polyethylene (UHMWPE) used in joint replacements, prosthetic knee and hip longevity may extend beyond two decades. However, it is difficult and costly to replicate such a long in vivo lifetime using clinically relevant in vitro wear testing approaches such as walking gait joint simulators. We advance a wear test intermediate in complexity between pin-on-disk and knee joint simulator tests. The test uses a surrogate contact pair, consisting of a surrogate femoral and tibial specimen that replicate the contact mechanics of any full-scale knee condyle contact pair. The method is implemented in a standard multi-directional pin-on-disk wear test machine, and we demonstrate its application via a two-million-cycle wear test of three different UHMWPE formulations. Further, we demonstrate the use of digital photography and image processing to accurately quantify fatigue damage based on the reduced transmission of light through a damage area in a UHMWPE specimen. The surrogate contact pairs replicate the knee condyle contact areas within -3% to +12%. The gravimetric wear test results reflect the dose of crosslinking radiation applied to the UHMWPE: 35 kGy yielded a wear rate of 7.4 mg/Mcycles, 55 kGy yielded 1.0 mg/Mcycles, and 75 kGy (applied to a 0.1% vitamin E stabilized UHMWPE) yielded 1.5 mg/Mcycles. A precursor to spalling fatigue is observed and precisely measured in the radiation-sterilized (35 kGy) and aged UHMWPE specimen. The presented techniques can be used to evaluate the high-cycle fatigue performance of arbitrary knee condyle contact pairs under design-specific contact stresses, using existing wear test machines. This makes the techniques more economical and well-suited to standardized comparative testing. © 2015 Wiley Periodicals, Inc.

  15. A new method to make 2-D wear measurements less sensitive to projection differences of cemented THAs.

    PubMed

    The, Bertram; Flivik, Gunnar; Diercks, Ron L; Verdonschot, Nico

    2008-03-01

    Wear curves from individual patients often show unexplained irregular wear curves or impossible values (negative wear). We postulated errors of two-dimensional wear measurements are mainly the result of radiographic projection differences. We tested a new method that makes two-dimensional wear measurements less sensitive for radiograph projection differences of cemented THAs. The measurement errors that occur when radiographically projecting a three-dimensional THA were modeled. Based on the model, we developed a method to reduce the errors, thus approximating three-dimensional linear wear values, which are less sensitive for projection differences. An error analysis was performed by virtually simulating 144 wear measurements under varying conditions with and without application of the correction: the mean absolute error was reduced from 1.8 mm (range, 0-4.51 mm) to 0.11 mm (range, 0-0.27 mm). For clinical validation, radiostereometric analysis was performed on 47 patients to determine the true wear at 1, 2, and 5 years. Subsequently, wear was measured on conventional radiographs with and without the correction: the overall occurrence of errors greater than 0.2 mm was reduced from 35% to 15%. Wear measurements are less sensitive to differences in two-dimensional projection of the THA when using the correction method.

  16. Dual mobility hip arthroplasty wear measurement: Experimental accuracy assessment using radiostereometric analysis (RSA).

    PubMed

    Pineau, V; Lebel, B; Gouzy, S; Dutheil, J-J; Vielpeau, C

    2010-10-01

    The use of dual mobility cups is an effective method to prevent dislocations. However, the specific design of these implants can raise the suspicion of increased wear and subsequent periprosthetic osteolysis. Using radiostereometric analysis (RSA), migration of the femoral head inside the cup of a dual mobility implant can be defined to apprehend polyethylene wear rate. The study aimed to establish the precision of RSA measurement of femoral head migration in the cup of a dual mobility implant, and its intra- and interobserver variability. A total hip prosthesis phantom was implanted and placed under weight loading conditions in a simulator. Model-based RSA measurement of implant penetration involved specially machined polyethylene liners with increasing concentric wear (no wear, then 0.25, 0.5 and 0.75mm). Three examiners, blinded to the level of wear, analyzed (10 times) the radiostereometric films of the four liners. There was one experienced, one trained, and one inexperienced examiner. Statistical analysis measured the accuracy, precision, and intra- and interobserver variability by calculating Root Mean Square Error (RMSE), Concordance Correlation Coefficient (CCC), Intra Class correlation Coefficient (ICC), and Bland-Altman plots. Our protocol, that used a simple geometric model rather than the manufacturer's CAD files, showed precision of 0.072mm and accuracy of 0.034mm, comparable with machining tolerances with low variability. Correlation between wear measurement and true value was excellent with a CCC of 0.9772. Intraobserver reproducibility was very good with an ICC of 0.9856, 0.9883 and 0.9842, respectively for examiners 1, 2 and 3. Interobserver reproducibility was excellent with a CCC of 0.9818 between examiners 2 and 1, and 0.9713 between examiners 3 and 1. Quantification of wear is indispensable for the surveillance of dual mobility implants. This in vitro study validates our measurement method. Our results, and comparison with other studies using different measurement technologies (RSA, standard radiographs, Martell method) make model-based RSA the reference method for measuring the wear of total hip prostheses in vivo. Level 3. Prospective diagnostic study. Copyright © 2010 Elsevier Masson SAS. All rights reserved.

  17. Impact of tool wear on cross wedge rolling process stability and on product quality

    NASA Astrophysics Data System (ADS)

    Gutierrez, Catalina; Langlois, Laurent; Baudouin, Cyrille; Bigot, Régis; Fremeaux, Eric

    2017-10-01

    Cross wedge rolling (CWR) is a metal forming process used in the automotive industry. One of its applications is in the manufacturing process of connecting rods. CWR transforms a cylindrical billet into a complex axisymmetrical shape with an accurate distribution of material. This preform is forged into shape in a forging die. In order to improve CWR tool lifecycle and product quality it is essential to understand tool wear evolution and the physical phenomena that change on the CWR process due to the resulting geometry of the tool when undergoing tool wear. In order to understand CWR tool wear behavior, numerical simulations are necessary. Nevertheless, if the simulations are performed with the CAD geometry of the tool, results are limited. To solve this difficulty, two numerical simulations with FORGE® were performed using the real geometry of the tools (both up and lower roll) at two different states: (1) before starting lifecycle and (2) end of lifecycle. The tools were 3D measured with ATOS triple scan by GOM® using optical 3D measuring techniques. The result was a high-resolution point cloud of the entire geometry of the tool. Each 3D point cloud was digitalized and converted into a STL format. The geometry of the tools in a STL format was input for the 3D simulations. Both simulations were compared. Defects of products obtained in simulation were compared to main defects of products found industrially. Two main defects are: (a) surface defects on the preform that are not fixed in the die forging operation; and (b) Preform bent (no longer straight), with two possible impacts: on the one hand that the robot cannot grab it to take it to the forging stage; on the other hand, an unfilled section in the forging operation.

  18. Wearing a Wetsuit Alters Upper Extremity Motion during Simulated Surfboard Paddling

    PubMed Central

    Nessler, J. A.; Silvas, M.; Carpenter, S.; Newcomer, S. C.

    2015-01-01

    Surfers often wear wetsuits while paddling in the ocean. This neoprene covering may be beneficial to upper extremity movement by helping to improve proprioceptive acuity, or it may be detrimental by providing increased resistance. The purpose of this study was to evaluate the effects of wearing a wetsuit on muscle activation, upper extremity motion, heart rate, and oxygen consumption during simulated surfboard paddling in the laboratory. Twelve male, recreational surfers performed two paddling trials at a constant workload on a swim bench ergometer both with and without a wetsuit. Kinematic data and EMG were acquired from the right arm via motion capture, and oxygen consumption and heart rate were recorded with a metabolic cart and heart rate monitor. Wearing a wetsuit had no significant effect on oxygen consumption or heart rate. A significant increase in EMG activation was observed for the middle deltoid but not for any of the other shoulder muscle evaluated. Finally, approximate entropy and estimates of the maximum Lyapunov exponent increased significantly for vertical trajectory of the right wrist (i.e. stroke height) when a wetsuit was worn. These results suggest that a 2mm wetsuit has little effect on the energy cost of paddling at lower workloads but does affect arm motion. These changes may be the result of enhanced proprioceptive acuity due to mechanical compression from the wetsuit. PMID:26551321

  19. Quantification of in vitro wear of a synthetic meniscus implant using gravimetric and micro-CT measurements.

    PubMed

    Elsner, Jonathan J; Shemesh, Maoz; Shefy-Peleg, Adaya; Gabet, Yankel; Zylberberg, Eyal; Linder-Ganz, Eran

    2015-09-01

    A synthetic meniscus implant was recently developed for the treatment of patients with mild to moderate osteoarthritis with knee pain associated with medial joint overload. The implant is distinctively different from most orthopedic implants in its pliable construction, and non-anchored design, which enables implantation through a mini-arthrotomy without disruption to the bone, cartilage, and ligaments. Due to these features, it is important to show that the material and design can withstand knee joint conditions. This study evaluated the long-term performance of this device by simulating loading for a total of 5 million gait cycles (Mc), corresponding to approximately five years of service in-vivo. All five implants remained in good condition and did not dislodge from the joint space during the simulation. Mild abrasion was detected by electron microscopy, but µ-CT scans of the implants confirmed that the damage was confined to the superficial surfaces. The average gravimetric wear rate was 14.5 mg/Mc, whereas volumetric changes in reconstructed µ-CT scans point to an average wear rate of 15.76 mm(3)/Mc (18.8 mg/Mc). Particles isolated from the lubricant had average diameter of 15 µm. The wear performance of this polycarbonate-urethane meniscus implant concept under ISO-14243 loading conditions is encouraging. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Phenomenological modeling of abradable wear in turbomachines

    NASA Astrophysics Data System (ADS)

    Berthoul, Bérenger; Batailly, Alain; Stainier, Laurent; Legrand, Mathias; Cartraud, Patrice

    2018-01-01

    Abradable materials are widely used as coatings within compressor and turbine stages of modern aircraft engines in order to reduce operating blade-tip/casing clearances and thus maximize energy efficiency. However, rubbing occurrences between blade tips and coating liners may lead to high blade vibratory levels and endanger their structural integrity through fatigue mechanisms. Accordingly, there is a need for a better comprehension of the physical phenomena at play and for an accurate modeling of the interaction, in order to predict potentially unsafe events. To this end, this work introduces a phenomenological model of the abradable coating removal based on phenomena reported in the literature and accounting for key frictional and wear mechanisms including plasticity at junctions, ploughing, micro-rupture and machining. It is implemented within an in-house software solution dedicated to the prediction of full three-dimensional blade/abradable coating interactions within an aircraft engine low pressure compressor. Two case studies are considered. The first one compares the results of an experimental abradable test rig and its simulation. The second one deals with the simulation of interactions in a complete low-pressure compressor. The consistency of the model with experimental observations is underlined, and the impact of material parameter variations on the interaction and wear behavior of the blade is discussed. It is found that even though wear patterns are remarkably robust, results are significantly influenced by abradable coating material properties.

  1. Tribological performance of the biological components of synovial fluid in artificial joint implants

    NASA Astrophysics Data System (ADS)

    Ghosh, Subir; Choudhury, Dipankar; Roy, Taposh; Moradi, Ali; Masjuki, H. H.; Pingguan-Murphy, Belinda

    2015-08-01

    The concentration of biological components of synovial fluid (such as albumin, globulin, hyaluronic acid, and lubricin) varies between healthy persons and osteoarthritis (OA) patients. The aim of the present study is to compare the effects of such variation on tribological performance in a simulated hip joint model. The study was carried out experimentally by utilizing a pin-on-disk simulator on ceramic-on-ceramic (CoC) and ceramic-on-polyethylene (CoP) hip joint implants. The experimental results show that both friction and wear of artificial joints fluctuate with the concentration level of biological components. Moreover, the performance also varies between material combinations. Wear debris sizes and shapes produced by ceramic and polyethylene were diverse. We conclude that the biological components of synovial fluid and their concentrations should be considered in order to select an artificial hip joint to best suit that patient.

  2. Multidirectional wear and impact-to-wear tests of phospholipid-polymer-grafted and vitamin E-blended crosslinked polyethylene: a pilot study.

    PubMed

    Kyomoto, Masayuki; Moro, Toru; Takatori, Yoshio; Tanaka, Sakae; Ishihara, Kazuhiko

    2015-03-01

    Modifying the surface and substrate of a crosslinked polyethylene (CLPE) liner may be beneficial for high wear resistance as well as high oxidative stability and excellent mechanical properties, which would be useful in contributing to the long-term performance of orthopaedic bearings. A grafted poly(2-methacryloyloxyethyl phosphorylcholine) (PMPC) layer on a vitamin E-blended crosslinked PE (HD-CLPE[VE]) surface may provide hydrophilicity and lubricity without compromising the oxidative stability or mechanical properties. (1) Will the modifications (PMPC grafting and vitamin E blending) affect the lubrication characteristics of the CLPE surface? (2) Will the modifications affect wear resistance? (3) Will the modifications affect fatigue resistance? We investigated the effects of surface and substrate modifications (PMPC grafting and vitamin E blending) on the wear and fatigue fracture of thin CLPE samples. For each of the untreated and PMPC-grafted CLPE surfaces with and without vitamin E blended (four groups), wettability and lubricity surface analyses were conducted as well as multidirectional wear and impact-to-wear tests using a pin-on-disk testing machine. The water wettability and lubricity (CLPE [mean ± 95% confidence interval]: 23.2° ± 1.8°, 0.005 ± 0.001; HD-CLPE[VE]: 26.0° ± 2.3°, 0.009 ± 0.003) of the PMPC-grafted surfaces were greater (p < 0.001) than that (CLPE: 90.3° ± 1.2°, 0.067 ± 0.015; HD-CLPE[VE]: 90.8° ± 2.0°, 0.063 ± 0.008) of the untreated surface regardless of vitamin E additives. It was observed that the PMPC grafting (CLPE: 0.23 ± 0.06 mg; HD-CLPE[VE]: 0.05 ± 0.10 mg) was associated with reduced gravimetric wear (CLPE: 0.53 ± 0.08 mg, p = 0.004 HD-CLPE[VE]: 0.23 ± 0.07 mg, p = 0.038) in the multidirectional wear test. The PMPC-grafted surface characteristics did not appear to affect the impact fatigue resistance regardless of vitamin E blending. PMPC grafting improved the surface hydrophilicity and lubricity, and it reduced the gravimetric wear in terms of multidirectional sliding. It did not result in differences in terms of the impact-to-unidirectional sliding regardless of vitamin E blending. Further research is needed to evaluate the wear resistance of PMPC-grafted HD-CLPE(VE) in long-term hip simulator tests under normal and severe conditions, which may offer useful clues to the possible performance of these materials in vivo. Our preliminary in vitro findings suggest that some improvement in the wear performance of crosslinked polyethylene acetabular liners in total hip arthroplasty could be obtained using PMPC grafting. Further research is needed to evaluate the wear resistance of PMPC-grafted HD-CLPE(VE) in long-term hip simulator tests under normal and severe conditions, which may offer useful clues to the possible performance of these materials in vivo.

  3. Exploring student nurses' attitudes towards those who are obese and whether these attitudes change following a simulated activity.

    PubMed

    Hunter, Janet; Rawlings-Anderson, Karen; Lindsay, Tracy; Bowden, Tracey; Aitken, Leanne M

    2018-06-01

    As the prevalence of obesity increases worldwide the field of bariatric medicine has emerged, focussing on the causes, prevention and treatment of obesity. People who are obese regularly face bias from healthcare professionals, which can negativity impact on care delivery and patient outcomes. The introduction of bariatric empathy suits into simulated practice may enable student nurses to appreciate the needs of, and influence their attitudes towards, obese people. The aim of this study was to explore student nurses' attitudes towards those who are obese and whether these attitudes change following a simulated activity. A mixed methods study incorporating a pre-post design. A UK university which provides pre-registration nursing education. Nursing students in part 1 (n = 39) and part 2 (n = 29) in adult and mental health fields. Part 1 and 2 nursing students completed the "Nurses' attitudes towards obesity and obese patients scale" (NATOOPS) questionnaire. Part 2 students also took part in a simulation activity while wearing a bariatric empathy suit and completed the NATOOPS questionnaire again immediately after the simulation activity. Students who wore the empathy suits were invited to a focus group. Part 1 students reported poorer attitudes on the NATOOPS scale than Part 2 students. After wearing the bariatric empathy suits students reported changed attitudes on the NATOOPS in three areas: response to obese patients, characteristics of obese patients and supportive roles in caring for obese patients. Five themes emerged from the focus groups related to physical and psychological impact of the suits; thinking differently; simulation as a learning experience and challenges and recommendations. Following a structured educational experience student nurses' attitudes were more positive towards obese patients. The characteristics of the educational activity that appeared to influence student nurses' attitudes was related to the "lived experience" of wearing bariatric empathy suits. Copyright © 2018 Elsevier Ltd. All rights reserved.

  4. Wear resistance of hydrophobic surfaces

    NASA Astrophysics Data System (ADS)

    Martinez, MA; Abenojar, J.; Pantoja, M.; López de Armentia, S.

    2017-05-01

    Nature has been an inspiration source to develop artificial hydrophobic surfaces. During the latest years the development of hydrophobic surfaces has been widely researched due to their numerous ranges of industrial applications. Industrially the use of hydrophobic surfaces is being highly demanded. This is why many companies develop hydrophobic products to repel water, in order to be used as coatings. Moreover, these coating should have the appropriated mechanical properties and wear resistance. In this work wear study of a hydrophobic coating on glass is carried out. Hydrophobic product used was Sika Crystal Dry by Sika S.A.U. (Alcobendas, Spain). This product is currently used on car windshield. To calculate wear resistance, pin-on-disk tests were carried out in dry and water conditions. The test parameters were rate, load and sliding distance, which were fixed to 60 rpm, 5 N and 1000 m respectively. A chamois was used as pin. It allows to simulate a real use. The friction coefficient and loss weight were compared to determinate coating resistance

  5. Effect of the environment on wear ranking and corrosion of biomedical CoCrMo alloys.

    PubMed

    Muñoz, A Igual; Mischler, S

    2011-03-01

    The corrosion behaviour and the wear ranking of biomedical high carbon (HC) and low carbon (LC) CoCrMo alloys sliding against an alumina ball in four different simulated body fluids [NaCl and phosphate buffered solutions (PBS) with and without albumin] has been analyzed by tribocorrosion and electrochemical techniques. The effects of alloy and of albumin on corrosion depend on the base electrolyte: differences between LC and HC alloy were only observed in NaCl solutions but not in PBS. Albumin increased significantly corrosion of both alloys in PBS solutions while its effect in NaCl was smaller. The wear ranking of the HC and LC alloys also depends on the environment. In the present study, HC CoCrMo alloy had lower wear resistance in NaCl and PBS + albumin than the LC alloy, while no differences between both alloys were found in the other solutions. This was attributed to surface chemical effects affecting third body behaviour.

  6. Modeling of complex wear behavior associated with grid-to-rod fretting in light water nuclear reactors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Blau, P. J.; Qu, J.; Lu, R.

    One significant concern in the operation of light water nuclear reactors is the fretting wear damage to fuel cladding from flow-induced vibrations. For years, research on the grid-to-rod fretting (GTRF) phenomena has been underway in countries where nuclear power production is a significant industry. Under the auspices of the U.S. Department of Energy Consortium for Advanced Simulation of Light Water Reactors, an effort has been underway to develop and test an engineering wear model for zirconium alloy fuel rod cladding against a supporting grid. Furthermore, the multi-stage model accounts for oxide layers and wear rate transitions. Our paper describes themore » basis for a GTRF engineering wear model, the physical significance of the wear factor it contains, and recent progress toward model validation based on a fretting wear testing apparatus that accounts for coolant temperature, pressure, and the presence of periodic impacts (gaps) in grid/rod contact.« less

  7. Modeling of complex wear behavior associated with grid-to-rod fretting in light water nuclear reactors

    DOE PAGES

    Blau, P. J.; Qu, J.; Lu, R.

    2016-09-21

    One significant concern in the operation of light water nuclear reactors is the fretting wear damage to fuel cladding from flow-induced vibrations. For years, research on the grid-to-rod fretting (GTRF) phenomena has been underway in countries where nuclear power production is a significant industry. Under the auspices of the U.S. Department of Energy Consortium for Advanced Simulation of Light Water Reactors, an effort has been underway to develop and test an engineering wear model for zirconium alloy fuel rod cladding against a supporting grid. Furthermore, the multi-stage model accounts for oxide layers and wear rate transitions. Our paper describes themore » basis for a GTRF engineering wear model, the physical significance of the wear factor it contains, and recent progress toward model validation based on a fretting wear testing apparatus that accounts for coolant temperature, pressure, and the presence of periodic impacts (gaps) in grid/rod contact.« less

  8. Validation of Accelerometer-Based Energy Expenditure Prediction Models in Structured and Simulated Free-Living Settings

    ERIC Educational Resources Information Center

    Montoye, Alexander H. K.; Conger, Scott A.; Connolly, Christopher P.; Imboden, Mary T.; Nelson, M. Benjamin; Bock, Josh M.; Kaminsky, Leonard A.

    2017-01-01

    This study compared accuracy of energy expenditure (EE) prediction models from accelerometer data collected in structured and simulated free-living settings. Twenty-four adults (mean age 45.8 years, 50% female) performed two sessions of 11 to 21 activities, wearing four ActiGraph GT9X Link activity monitors (right hip, ankle, both wrists) and a…

  9. Friction and wear of carbon-graphite materials for high energy brakes

    NASA Technical Reports Server (NTRS)

    Bill, R. C.

    1975-01-01

    Caliper-type brakes simulation experiments were conducted on seven different carbon-graphite material formulations against a steel disk material and against a carbon-graphite disk material. The effects of binder level, boron carbide (B4C) additions, graphite fiber additions, and graphite cloth reinforcement on friction and wear behavior were investigated. Reductions in binder level and additions of B4C each resulted in increased wear. The wear rate was not affected by the addition of graphite fibers. Transition to severe wear and high friction was observed in the case of graphite-cloth-reinforced carbon sliding against a disk of similar composition. This transition was related to the disruption of a continuous graphite shear film that must form on the sliding surfaces if low wear is to occur. The exposure of the fiber structure of the cloth constituent is believed to play a role in the shear film disruption.

  10. Simulation of enamel wear for reconstruction of diet and feeding behavior in fossil animals: A micromechanics approach.

    PubMed

    Constantino, Paul J; Borrero-Lopez, Oscar; Pajares, Antonia; Lawn, Brian R

    2016-01-01

    The deformation and wear events that underlie microwear and macrowear signals commonly used for dietary reconstruction in fossil animals can be replicated and quantified by controlled laboratory tests on extracted tooth specimens in conjunction with fundamental micromechanics analysis. Key variables governing wear relations include angularity, stiffness (modulus), and size of the contacting particle, along with material properties of enamel. Both axial and sliding contacts can result in the removal of tooth enamel. The degree of removal, characterized by a "wear coefficient," varies strongly with particle content at the occlusal interface. Conditions leading to a transition from mild to severe wear are discussed. Measurements of wear traces can provide information about contact force and particle shape. The potential utility of the micromechanics methodology as an adjunct for investigating tooth durability and reconstructing diet is explored. © 2015 WILEY Periodicals, Inc.

  11. Preliminary Assessment of Seals for Dust Mitigation of Mechanical Components for Lunar Surface Systems

    NASA Technical Reports Server (NTRS)

    Delgado, Irebert R.; Handschuh, Michael J.

    2010-01-01

    Component tests were conducted on spring-loaded Teflon seals to determine their performance in keeping lunar simulant out of mechanical component gearbox, motor, and bearing housings. Baseline tests were run in a dry-room without simulant for 10,000 cycles to determine wear effects of the seal against either anodized aluminum or stainless steel shafts. Repeat tests were conducted using lunar simulants JSC-1A and LHT-2M. Finally, tests were conducted with and without simulant in vacuum at ambient temperature. Preliminary results indicate minimal seal and shaft wear through 10,000 cycles, and more importantly, no simulant was observed to pass through the seal-shaft interface. Future endurance tests are planned at relevant NASA Lunar Surface System architecture shaft sizes and operating conditions.

  12. Retention and wear behaviors of two implant overdenture stud-type attachments at different implant angulations.

    PubMed

    Choi, Jae-Won; Bae, Ji-Hyeon; Jeong, Chang-Mo; Huh, Jung-Bo

    2017-05-01

    Implant angulation should be considered when selecting an attachment. Some in vitro studies have investigated the relationship between implant angulation and changes in the retention force of the stud attachment, but few studies have evaluated the effect of cyclic loading and repeated cycles of insertion and removal on the stud attachment. The purpose of this in vitro study was to evaluate the effects of implant angulation on the retentive characteristics of overdentures with 2 different stud attachments, an experimental system and O-rings in red and orange, after cyclic loading and repeated insertion and removal cycles. The canine region of a mandibular experimental model was fitted with 2 implant fixtures with 2 different stud attachment systems at implant angulations of 0, 15, or 30 degrees. A mastication simulator was used to simulate cyclic loading, and a universal testing machine was used to evaluate retentive force changes after repeated insertion and removal cycles. To simulate the numbers of mastication and insertion and removal cycles per annum, 400000 cyclic loadings and 1080 insertion and removal cycles were performed. Wear patterns and attachment surface deformations were evaluated by scanning electron microscopy. Data were analyzed using the Kruskal-Wallis test, Mann-Whitney U test with Bonferroni correction (α=.05/3=.017), and the paired-sample Student t test (α=.05). When retentive forces before and after testing were compared, O-ring showed significant retention loss at all implant angulations (P<.001). In contrast, the experimental system showed little retention loss in the 0- and 15-degree models (P>.05), whereas the 30-degree model showed a significant increase in retentive force (P=.001). At all implant angulations, retention loss increased significantly for the orange O-ring, followed by the red O-ring, and the experimental system (P<.001). Scanning electron microscopy analysis showed more intense wear in the matrix than the patrix (abutment that matches to matrix) and more severe wear and deformation of the O-ring rubber matrix than of the experimental zirconia ball. Upon completion of the experiment, wear and deformation were found for all attachment systems. Even when implants are not installed in parallel, the experimental system can be used without involving great loss of retention. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  13. Multi-objective optimization of swash plate forging process parameters for the die wear/service life improvement

    NASA Astrophysics Data System (ADS)

    Hu, X. F.; Wang, L. G.; Wu, H.; Liu, S. S.

    2017-12-01

    For the forging process of the swash plate, the author designed a kind of multi-index orthogonal experiment. Based on the Archard wear model, the influences of billet temperature, die temperature, forming speed, top die hardness and friction coefficient on forming load and die wear were numerically simulated by DEFORM software. Through the analysis of experimental results, the best forging process parameters were optimized and determined, which could effectively reduce the die wear and prolong the die service life. It is significant to increase the practical production of enterprise, especially to reduce the production cost and to promote enterprise profit.

  14. Wear of primary teeth caused by opposed all-ceramic or stainless steel crowns

    PubMed Central

    Bae, Ik-Hyun; Noh, Tae-Hwan; Ju, Sung-Won; Lee, Tae-Kyoung; Ahn, Jin-Soo; Jeong, Tae-Sung

    2016-01-01

    PURPOSE This study was conducted to evaluate the effects of full-coverage all-ceramic zirconia, lithium disilicate glass-ceramic, leucite glass-ceramic, or stainless steel crowns on antagonistic primary tooth wear. MATERIALS AND METHODS There were four study groups: the stainless steel (Steel) group, the leucite glass-ceramic (Leucite) group, the lithium disilicate glass-ceramic (Lithium) group, and the monolithic zirconia (Zirconia) group. Ten flat crown specimens were prepared per group; opposing teeth were prepared using primary canines. A wear test was conducted over 100,000 chewing cycles using a dual-axis chewing simulator and a 50 N masticating force, and wear losses of antagonistic teeth and restorative materials were calculated using a three-dimensional profiling system and an electronic scale, respectively. Statistical significance was determined using One-way ANOVA and Tukey's test (P<.05). RESULTS The Leucite group (2.670±1.471 mm3) showed the greatest amount of antagonist tooth wear, followed by in decreasing order by the Lithium (2.042±0.696 mm3), Zirconia (1.426±0.477 mm3), and Steel groups (0.397±0.192 mm3). Mean volume losses in the Leucite and Lithium groups were significantly greater than in the Steel group (P<.05). No significant difference was observed between mean volume losses in the Zirconia and Steel groups (P>.05). CONCLUSION Leucite glass-ceramic and lithium disilicate glass-ceramic cause more primary tooth wear than stainless steel or zirconia. PMID:26949487

  15. A Multidirectional Tribo-System: Wear of UHMWPE under Sliding, Rolling, and Rotation

    NASA Astrophysics Data System (ADS)

    Patten, Elias Wolfgang

    Total knee replacements (TKR) have become a successful surgical procedure for addressing end-stage osteoarthritis, with ultra-high molecular weight polyethylene and cobalt chrome alloy (UHMWPE/Co-Cr) serving as the bearing materials of choice for decades. However, more than 10% of TKRs fail and require revision surgery. The predominant challenge with UHMWPE is the particulate debris generated through wear-mediated processes; wear debris from the UHMWPE tibial bearing surface leading to loosening is still the main cause for post-fifth-year revisions. UHMWPE wear in hip arthroplasty has been linked to microstructural evolution at the surface from multidirectional sliding in the hip joint but little is known about how the microstructure responds to clinically relevant sliding conditions in the knee. This is likely because wear tests are typically performed under basic motion parameters with simplified geometry (pin-on-disk tests) while the knee has more complex kinematics: it is neither a ball-and-socket joint nor a simple hinge joint, but has 2D sliding, rolling/slip motion, and rotation. There is also disagreement over how to best quantify cross-shear and how to model how much wear it will cause. A custom multidirectional tribo-system was used to investigate the individual and combined effects of the different motions in TKR: 2D sliding, rolling, and rotation, for a total of eight separate kinematic conditions. The trends in wear rates and wear factors for these different motions were compared with many different definitions for magnitudes and ratios of cross-shear. Additionally, the wear surfaces were examined for wear mechanism and the microstructural changes in lamellae orientation for the different motions were analyzed. To mimic the tribological conditions of a condyle in a TKR, polished Co-Cr spheres were articulated against flat, smooth UHMWPE disks with physiologically relevant loading, speed, and lubrication conditions. The motion parameters were selected based on the lowest and highest reasonable amounts of cross-shear that each motion type would generate during a realistic gait cycle: a reciprocating line or a "figure 8" with a 15° crossing angle, no rolling or a 0.4 slide-to-roll ratio, and no rotation or a 1°/mm of rotation. The amount of wear was measured with optical profilometry of the cross-section at the middle of the wear scar, after allowing for a resting period for the material creep to recover. To calculate the amount of cross-shear at this cross-section, the sliding interface was simulated with a computer Matlab model. Multiple definitions of cross-shear were used, including the traditional, cycle-based approaches and newer, memory-based approaches. The wear surfaces were examined using optical microscopy and scanning electron microscopy (SEM). The lamellar microstructure at the wear surface and below the wear surface was examined using an oxidizing etch to remove the amorphous phase. The remaining lamellae were imaged using SEM and their orientations and alignment was quantified using an image analysis program. Wear factors were between 0.3 and 8.7 µm2/(Nm/mm), significantly increasing with motion complexity and cross-shear, with the "figure 8" sliding path having the greatest effect. Volumetric wear rates correlated linearly with the total amount of cross-shear, while wear factors correlated linearly with ratios of cross-shear. The best predictors of the wear factor were the normalized crossing intensity and normalized, memory-based cross-shear ratios, with R2 values of 0.98 and 0.97, although many of the cross-shear ratios also had a good linear fits with wear factor. The kinematic parameters in this experiment did not differentiate the various cross-shear parameters enough to conclusively determine which are most appropriate, although some have a stronger theoretical foundation than others. SEM analysis of the wear scar surface revealed slight scratching and instances of rippling and surface cracking perpendicular to the primary sliding directions. These are consistent with abrasive wear, plastic flow and adhesive wear, and fatigue wear mechanisms reported in other in vitro and in vivo wear studies. The orientations of the lamellae at the wear surfaces were not discernibly different from the lamellae of an unworn section of the disk surface. Similarly, the near-surface regions of the disk cross-section were not discernibly different from the subsurface regions. Previous studies have demonstrated orientation of the microstructure during wear using transmission electron microscopy, X-ray scattering, and Fourier transform infrared spectroscopy techniques, and such methods may be necessary for texture characterization. These results demonstrate that knee kinematics have a significant effect on the cross-shear and wear of UHMWPE and should not be neglected when designing TKR. A better theoretical understanding of how kinematics contribute to wear can lead to better UHMWPE formulations, improved computer simulations of wear, and optimized TKR designs with longer life-spans.

  16. Short-term corneal changes with gas-permeable contact lens wear in keratoconus subjects: a comparison of two fitting approaches.

    PubMed

    Romero-Jiménez, Miguel; Santodomingo-Rubido, Jacinto; Flores-Rodríguez, Patricia; González-Méijome, Jose-Manuel

    2015-01-01

    To evaluate changes in anterior corneal topography and higher-order aberrations (HOA) after 14-days of rigid gas-permeable (RGP) contact lens (CL) wear in keratoconus subjects comparing two different fitting approaches. Thirty-one keratoconus subjects (50 eyes) without previous history of CL wear were recruited for the study. Subjects were randomly fitted to either an apical-touch or three-point-touch fitting approach. The lens' back optic zone radius (BOZR) was 0.4mm and 0.1mm flatter than the first definite apical clearance lens, respectively. Differences between the baseline and post-CL wear for steepest, flattest and average corneal power (ACP) readings, central corneal astigmatism (CCA), maximum tangential curvature (KTag), anterior corneal surface asphericity, anterior corneal surface HOA and thinnest corneal thickness measured with Pentacam were compared. A statistically significant flattening was found over time on the flattest and steepest simulated keratometry and ACP in apical-touch group (all p<0.01). A statistically significant reduction in KTag was found in both groups after contact lens wear (all p<0.05). Significant reduction was found over time in CCA (p=0.001) and anterior corneal asphericity in both groups (p<0.001). Thickness at the thinnest corneal point increased significantly after CL wear (p<0.0001). Coma-like and total HOA root mean square (RMS) error were significantly reduced following CL wearing in both fitting approaches (all p<0.05). Short-term rigid gas-permeable CL wear flattens the anterior cornea, increases the thinnest corneal thickness and reduces anterior surface HOA in keratoconus subjects. Apical-touch was associated with greater corneal flattening in comparison to three-point-touch lens wear. Copyright © 2014 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  17. Wear of ceramic and antagonist--a systematic evaluation of influencing factors in vitro.

    PubMed

    Heintze, S D; Cavalleri, A; Forjanic, M; Zellweger, G; Rousson, V

    2008-04-01

    (1) To systematically review the existing literature on in vitro assessments of antagonist wear of ceramic materials; (2) To systematically evaluate possible influencing factors on material and antagonist wear of ceramic specimens. The database MEDLINE was searched with the terms "enamel," "wear" and "antagonist." The selected studies were analyzed with regard to wear parameters, type of antagonist and outcome. In the laboratory study, three ceramic materials were selected with different compositions and physical properties: IPS d.SIGN low-fusing metal ceramic, IPS Empress leucite ceramic, e.max Press lithium disilicate ceramic. These materials were subjected to the Ivoclar wear method (Willytec chewing simulator, 120,000cycles, 5kg weight) by systematically modifying the following variables which resulted in 36 tests with 8 specimens in each group: (1) configuration (flat, crown specimen), (2) surface treatment (polish, glaze), (3) type of antagonist (ceramic, two types of enamel stylus). Furthermore, the enamel styluses were cut to measure the enamel thickness and cusp width. Wear of both the material and the antagonist was quantified by scanning plaster replicas of the specimens with a laser scanner (etkon es1) and matching baseline and follow-up data with the Match 3D software (Willytec). The data were log-transformed to stabilize the variance and achieve near normality. To test the influence of specific test parameters, a four-way ANOVA with post hoc tests and Bonferroni correction was applied. The systematic review revealed 20 in vitro studies in which a material and the antagonist wear of the same material was examined. However, the results were inconsistent mainly due to the fact that the test parameters differed widely. Most studies used prepared enamel from extracted molars as the antagonist and flat polished ceramic specimens. The test chamber was filled with water and some sort of sliding movement was integrated in the wear generating process. However, there was a huge variation in relation to the applied force, the used force actuator, the number of cycles, and the frequency of cycles per time as well as the number of specimens. The results of the systematic laboratory tests revealed that the following factors strongly influence the wear: configuration (more material wear of flat versus crown specimens), surface treatment (more antagonist wear of glazed versus polished specimens), the antagonist system (more material wear and less antagonist wear for ceramic stylus versus enamel stylus), and enamel thickness (less wear for thicker enamel). Material wear was not very much different between the materials. However, e.max Press generally caused more antagonist wear than the other two materials, which were quite similar. However, the main influencing factors did not yield consistent results for all the subgroups and there was a huge variability of results within the subgroups especially in those groups that used enamel as antagonist. As far as consistency and correlation with clinical studies is concerned, the set-up that consists of unprepared enamel of molar cusps against glazed crowns seems to be the most appropriate method to evaluate a ceramic material with regard to antagonist wear. However, due to the high variability of results large sample sizes are necessary to differentiate between materials, which calls the whole in vitro approach into question.

  18. A study of energy-size relationship and wear rate in a lab-scale high pressure grinding rolls unit

    NASA Astrophysics Data System (ADS)

    Rashidi Dashtbayaz, Samira

    This study is focused on two independent topics of energy-size relationship and wear-rate measurements on a lab-scale high pressure grinding rolls (HPGR). The first part of this study has been aimed to investigate the influence of the operating parameters and the feed characteristics on the particle-bed breakage using four different ore samples in a 200 mm x 100 mm lab-scale HPGR. Additionally, multistage grinding, scale-up from a lab-scale HPGR, and prediction of the particle size distributions have been studied in detail. The results obtained from energy-size relationship studies help with better understanding of the factors contributing to more energy-efficient grinding. It will be shown that the energy efficiency of the two configurations of locked-cycle and open multipass is completely dependent on the ore properties. A test procedure to produce the scale-up data is presented. The comparison of the scale-up factors between the data obtained on the University of Utah lab-scale HPGR and the industrial machine at the Newmont Boddington plant confirmed the applicability of lab-scale machines for trade-off studies. The population balance model for the simulation of product size distributions has shown to work well with the breakage function estimated through tests performed on the HPGR at high rotational speed. Selection function has been estimated by back calculation of population balance model with the help of the experimental data. This is considered to be a major step towards advancing current research on the simulation of particle size distribution by using the HPGR machine for determining the breakage function. Developing a technique/setup to measure the wear rate of the HPGR rolls' surface is the objective of the second topic of this dissertation. A mockup was initially designed to assess the application of the linear displacement sensors for measuring the rolls' weight loss. Upon the analysis of that technique and considering the corresponding sources of errors, the application of the 2D distance measurement sensors was studied to directly determine the wear rate on the lab-sale HPGR roll. Results obtained from various grinding tests revealed that the operating variations were beyond the expected wear rate. Based on the valuable outcomes from the two mentioned experimental designs, a cup-disc arrangement similar to piston-die apparatus was developed to indirectly measure the wear rate on the HPGR roll. The preliminary outputs proved to be promising for further investigation into the development of this method in order to relate the measured data on the cup-disc apparatus to the actual wear rate on the HPGR rolls.

  19. Studies on the Biotribological and Biological Behavior of Thermally Oxidized Ti6Al4V for Use in Artificial Cervical Disk

    NASA Astrophysics Data System (ADS)

    Wang, Song; Li, Junhui; Lu, Junzhe; Tyagi, Rajnesh; Liao, Zhenhua; Feng, Pingfa; Liu, Weiqiang

    2017-05-01

    The artificial cervical disk was simplified and considered as a ball-on-socket model with the material configuration of ultra-high molecular weight polyethylene and Ti6Al4V (PE-on-TC4). In order to improve the wear resistance, an optimized thermal oxidation (TO) coating was applied on TC4 component. The long-term wear behavior of the model was assessed in vitro using a wear simulator under 10 million cycles (MC) testing intervals. The biological behavior was investigated by bone marrow-derived mesenchymal stem cells (BMSCs) cell attachment and cell viability/proliferation assays, respectively. The total average wear rate for PE/TC4 pair was found to be 0.81 mg/MC, whereas the same was about 0.96 mg/MC for PE/TO pair. The wear rate of the metal has been neglected in comparison with that of the mating polymer. PE component was found to suffer severe damage characterized by scratches, fatigue cracks and arc-shaped wear grooves on the edge zone of ball. The dominant wear mechanism was abrasion for metal component while the dominant failure mechanism was a mix of plowing, fatigue and plastic deformation for polymer component. TO coating improved the cell attachment property of TC4, and the cell viability results were also quite good. TO coating protected TC4 from being plowed and avoided the release of toxic metal ions. However, this intensified the wear of PE component. Considering the biotribological and biological behavior in totality, TO coating could still be promising when applied in articulation surfaces.

  20. Localized wear of compomer restorative materials.

    PubMed

    Latta, M A; Barkmeier, W W; Wilwerding, T M; Blake, S M

    2001-08-01

    To determine and compare the localized wear of six compomer restorative materials. Ten specimens of Dyract, Dyract AP, F2000, Compoglass F, Elan and Hytac were prepared in a custom fixture and polished. A pretest surface profile was generated using an MTS 3-D surface profilometer and the specimens were subjected to 400,000 cycles in a Leinfelder wear machine equipped with a conical stylus tip to simulate localized wear. A post-test profile was generated and the before and after profiles were fitted and analyzed using AnSur 3-D software. The total volume loss and depth of the wear facet on each specimen was calculated and statistical analysis was accomplished (ANOVA and Tukey's test). Volume loss (mm3) was as follows: F2000, 0.027 +/- 0.002; Hytac, 0.007 +/- 0.023; Elan, 0.054 +/- 0.013; Compoglass F, 0.135 +/- 0.006; Dyract AP, 0.135 +/- 0.023; Dyract, 0.185 +/- 0.032. Maximum depth of the wear facets (microm) was as follows: F2000, 112.2 +/- 10.2; Hytac, 132.8 +/- 9.3; Elan, 144.3 +/- 23. 1; Compoglass F, 168.3 +/- 13.0; Dyract AP, 194.0 +/- 19.7; Dyract, 220.6 +/- 15.8. There was not a difference (P > 0.05) in volumetric loss between F2000 and Hytac or between Hytac and Elan. The volume loss and maximum depth of the wear facets of F2000, Hytac and Elan was significantly less (P< 0.05) than Compoglass F, Dyract AP and Dyract The results of this study indicate that there are significant differences in the in vitro wear rates of compomer materials.

  1. Aircrew Eye/Respiratory Protection (AERP): 16-Hour Extended Wear Evaluation of Chemical Protective Equipment.

    DTIC Science & Technology

    1994-02-01

    Respiratory Protection (AERP) and associated clothing and equipment. Two subjects each carried out simulated tanker/transport and fighter/attack scenarios. No...AD A277 288 N•.• AL-TP-1 993-0014 ý’vI~~I~ 11~ II~I AIRCREW EYE/ RESPIRATORY PROTECTION (AERP): 16-HOUR EXTENDED WEAR EVALUATION OF R CHEMICAL...S. FUNDING NUMBERS ’Aircrew Eye/ Respiratory Protection (AERP): 16-Hour Extended PE - 62202F Wear Evaluation of Chemical Protective Equipment PR

  2. Finite Element Simulation Methods for Dry Sliding Wear

    DTIC Science & Technology

    2008-03-27

    effects of wear only occur on a microscopic level (3; 14; 17). A third reason that wear is not well understood is that it involves many different...material or one with a higher coefficient of friction there will be more of a problem with high pressure points. A third possibility is to spread the...For the local model the rail is modeled as a deformable body , and a small, 1 mm, square is taken from the slipper as the submodel. 5.2 The Global

  3. Macro- and microtopographical examination and quantification of CAD-CAM composite resin 2- and 3-body wear.

    PubMed

    Stöckl, Carolin; Hampe, Rüdiger; Stawarczyk, Bogna; Haerst, Miriam; Roos, Malgorzata

    2018-04-05

    The selection of an appropriate restorative material based on wear behavior is important for the long-term success of a dental restoration. For computer-aided design and computer-aided manufacturing (CAD-CAM) composite resins, information about their wear resistance and wear mechanism is scarce. The purpose of this in vitro study was to compare the 2- and 3-body wear of CAD-CAM composite resins with that of lithium disilicate ceramic and to develop analysis software. Flat specimens were prepared from the following CAD-CAM composite resins: Cerasmart (CS), SHOFU Block HC (SH), Katana Avencia (KA), Brilliant Crios (BC), an experimental composite resin (EXP), and lithium disilicate ceramic IPS e.max CAD (REF). The specimens underwent 2-body wear (50 N, 5/55°C, 400 000 cycles) opposed by human enamel antagonists. Specimen wheels were prepared with each material on each wheel for 3-body wear with a millet slurry (15 N, 15% slip, 200 000 cycles). All specimens were digitized by using a dedicated laser scanner. Analysis software was developed to calculate macrotopographical examination of volume loss. The microtopography of the surfaces was examined by using scanning electron microscopy. For data analysis, the Kruskal-Wallis test with the Tukey-Kramer post hoc test and the 1-sample Wilcoxon test were used (α=.05). After 2-body wear simulation, SH and KA presented higher volume loss than the other CAD-CAM materials. For 3-body wear, REF had lower volume loss than CS, SH, or BC. In addition, BC led to higher volume loss than EXP. The patterns of 2- and 3-body wear were different. The ceramic showed good global wear resistance. The volume loss of the CAD-CAM composite resins differed and depended on the material. The 2- and 3-body wear test methods tended to differ with regard to volume loss. Examination of the worn surfaces revealed different mechanisms acting in 2- and 3-body wear test. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  4. 3D finite element modeling of sliding wear

    NASA Astrophysics Data System (ADS)

    Buentello Hernandez, Rodolfo G.

    Wear is defined as "the removal of material volume through some mechanical process between two surfaces". There are many mechanical situations that can induce wear and each can involve many wear mechanisms. This research focuses on the mechanical wear due to dry sliding between two surfaces. Currently there is a need to identify and compare materials that would endure sliding wear under severe conditions such as high velocities. The high costs associated with the field experimentation of systems subject to high-speed sliding, has prevented the collection of the necessary data required to fully characterize this phenomena. Simulating wear through Finite Elements (FE) would enable its prediction under different scenarios and would reduce experimentation costs. In the aerospace, automotive and weapon industries such a model can aid in material selection, design and/or testing of systems subjected to wear in bearings, gears, brakes, gun barrels, slippers, locomotive wheels, or even rocket test tracks. The 3D wear model presented in this dissertation allows one to reasonably predict high-speed sliding mechanical wear between two materials. The model predictions are reasonable, when compared against those measured on a sled slipper traveling over the Holloman High Speed Tests Track. This slipper traveled a distance of 5,816 meters in 8.14 seconds and reached a maximum velocity of 1,530 m/s.

  5. Investigation of wear land and rate of locally made HSS cutting tool

    NASA Astrophysics Data System (ADS)

    Afolalu, S. A.; Abioye, A. A.; Dirisu, J. O.; Okokpujie, I. P.; Ajayi, O. O.; Adetunji, O. R.

    2018-04-01

    Production technology and machining are inseparable with cutting operation playing important roles. Investigation of wear land and rate of cutting tool developed locally (C=0.56%) with an HSS cutting tool (C=0.65%) as a control was carried out. Wear rate test was carried out using Rotopol -V and Impact tester. The samples (12) of locally made cutting tools and one (1) sample of a control HSS cutting tool were weighed to get the initial weight and grit was fixed at a point for the sample to revolve at a specific time of 10 mins interval. Approach of macro transfer particles that involved mechanism of abrasion and adhesion which was termed as mechanical wear to handle abrasion adhesion processes was used in developing equation for growth wear at flank. It was observed from the wear test that best minimum wear rate of 1.09 × 10-8 and 2.053 × 10-8 for the tools developed and control were measured. MATLAB was used to simulate the wear land and rate under different conditions. Validated results of both the experimental and modeling showed that cutting speed has effect on wear rate while cutting time has predicted measure on wear land. Both experimental and modeling result showed best performances of tools developed over the control.

  6. Failure Mechanisms of the Protective Coatings for the Hot Stamping Applications

    NASA Astrophysics Data System (ADS)

    Zhao, Chen

    In the present study, four different nitriding techniques were carried on the ductile irons NAAMS-D6510 and cast steels NAAMS-S0050A, which are widely used stamping die materials; duplex treatments (PVD CrN coating+nitriding) were carried on H13 steels, which are common inserts for the hot stamping dies. Inclined impact-sliding wear tests were performed on the nitriding cases under simulated stamping conditions. Surface profilometer, scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS) and X-ray photoelectron spectroscopy (XPS) were used to investigate the wear and failure mechanisms of the protective coatings. It was found that the nitrided ductile iron samples performed better than the nitrided cast steel specimens. High temperature inclined impact-sliding wear tests were carried out on the CrN coatings. It was found that the coating performed better at elevated temperature. XPS analysis indicated the top surface layer (about 3-4nm) of the coating was oxidized at 400 °C and formed a Cr2O3 protective film. The in-situ formation of the thin Cr2O3 protective layer likely led to the change of wear mechanisms from severe adhesive failure to mild abrasive wear.

  7. Development of a wear model for the wheel profile optimisation on railway vehicles

    NASA Astrophysics Data System (ADS)

    Ignesti, M.; Innocenti, A.; Marini, L.; Meli, E.; Rindi, A.

    2013-09-01

    The modelling and the reduction of wear due to wheel-rail interaction is a fundamental aspect in the railway field, mainly correlated to safety, maintenance interventions and costs. In this work, the authors present two innovative wheel profiles, specifically designed with the aim of improving the wear and stability behaviour of the standard ORE S1002 wheel profile matched with the UIC60 rail profile canted at 1/20 rad, which represents the wheel-rail combination adopted in the Italian railway line. The two wheel profiles, conventionally named CD1 and DR2, have been developed by the authors in collaboration with Trenitalia S.p.A. The CD1 profile has been designed with the purpose of spreading the contact points in the flange zone on a larger area in order to reduce wear phenomena and having a constant equivalent conicity for small lateral displacements of the wheelset with respect to the centred position in the track. The DR2 wheel profile is instead designed to guarantee the same kinematic characteristics of the matching formed by ORE S1002 wheel profile and UIC60 rail profile with laying angle α p equal to 1/40 rad, widely common in European railways and characterised by good performances in both wear and kinematic behaviour. The evolution of wheel profiles due to wear has been evaluated through a wear model developed and validated by the authors in previous works. The wear model comprises two mutually interactive units: a vehicle model for the dynamic simulations and a model for the wear assessment. The whole model is based on a discrete process: each discrete step consists in one dynamic simulation and one profile update by means of the wear model while, within the discrete step, the profiles are supposed to be constant. The choice of an appropriate step is crucial in terms of precision and computational effort: the particular strategy adopted in the current work has been chosen for its capacity in representing the nonlinear wear evolution and for the low computational time required. In the present research, the investigated trainset is the passenger vehicle ALSTOM ALn 501 'Minuetto', which is usually equipped with the standard ORE S1002 wheel profile in Italian railways. The entire model has been simulated on a virtual track specifically developed to represent a statistical description of the whole Italian line. The data necessary to build the virtual track and the vehicle model were provided by Trenitalia S.p.A. and Rete Ferroviaria Italiana. The CD1 and DR2 wheel profiles, matched to the UIC60 rail with cant 1/20 rad, have shown a good behaviour in terms of wear resistance if compared with the old ORE S1002 wheel profile, consequently assuring a more uniform distribution of the removed material and a prolongation of the mean time between two subsequent re-profiling interventions.

  8. Development and validation of a wear model for the analysis of the wheel profile evolution in railway vehicles

    NASA Astrophysics Data System (ADS)

    Auciello, J.; Ignesti, M.; Malvezzi, M.; Meli, E.; Rindi, A.

    2012-11-01

    The numerical wheel wear prediction in railway applications is of great importance for different aspects, such as the safety against vehicle instability and derailment, the planning of wheelset maintenance interventions and the design of an optimal wheel profile from the wear point of view. For these reasons, this paper presents a complete model aimed at the evaluation of the wheel wear and the wheel profile evolution by means of dynamic simulations, organised in two parts which interact with each other mutually: a vehicle's dynamic model and a model for the wear estimation. The first is a 3D multibody model of a railway vehicle implemented in SIMPACK™, a commercial software for the analysis of mechanical systems, where the wheel-rail interaction is entrusted to a C/C++user routine external to SIMPACK, in which the global contact model is implemented. In this regard, the research on the contact points between the wheel and the rail is based on an innovative algorithm developed by the authors in previous works, while normal and tangential forces in the contact patches are calculated according to Hertz's theory and Kalker's global theory, respectively. Due to the numerical efficiency of the global contact model, the multibody vehicle and the contact model interact directly online during the dynamic simulations. The second is the wear model, written in the MATLAB® environment, mainly based on an experimental relationship between the frictional power developed at the wheel-rail interface and the amount of material removed by wear. Starting from a few outputs of the multibody simulations (position of contact points, contact forces and rigid creepages), it evaluates the local variables, such as the contact pressures and local creepages, using a local contact model (Kalker's FASTSIM algorithm). These data are then passed to another subsystem which evaluates, by means of the considered experimental relationship, both the material to be removed and its distribution along the wheel profile, obtaining the correspondent worn wheel geometry. The wheel wear evolution is reproduced by dividing the overall chosen mileage to be simulated in discrete spatial steps: at each step, the dynamic simulations are performed by means of the 3D multibody model keeping the wheel profile constant, while the wheel geometry is updated through the wear model only at the end of the discrete step. Thus, the two parts of the whole model work alternately until the completion of the whole established mileage. Clearly, the choice of an appropriate step length is one of the most important aspects of the procedure and it directly affects the result accuracy and the required computational time to complete the analysis. The whole model has been validated using experimental data relative to tests performed with the ALn 501 'Minuetto' vehicle in service on the Aosta-Pre Saint Didier track; this work has been carried out thanks to a collaboration with Trenitalia S.p.A and Rete Ferroviaria Italiana, which have provided the necessary technical data and experimental results.

  9. Experimental assessment of precision and accuracy of radiostereometric analysis for the determination of polyethylene wear in a total hip replacement model.

    PubMed

    Bragdon, Charles R; Malchau, Henrik; Yuan, Xunhua; Perinchief, Rebecca; Kärrholm, Johan; Börlin, Niclas; Estok, Daniel M; Harris, William H

    2002-07-01

    The purpose of this study was to develop and test a phantom model based on actual total hip replacement (THR) components to simulate the true penetration of the femoral head resulting from polyethylene wear. This model was used to study both the accuracy and the precision of radiostereometric analysis, RSA, in measuring wear. We also used this model to evaluate optimum tantalum bead configuration for this particular cup design when used in a clinical setting. A physical model of a total hip replacement (a phantom) was constructed which could simulate progressive, three-dimensional (3-D) penetration of the femoral head into the polyethylene component of a THR. Using a coordinate measuring machine (CMM) the positioning of the femoral head using the phantom was measured to be accurate to within 7 microm. The accuracy and precision of an RSA analysis system was determined from five repeat examinations of the phantom using various experimental set-ups of the phantom. The accuracy of the radiostereometric analysis, in this optimal experimental set-up studied was 33 microm for the medial direction, 22 microm for the superior direction, 86 microm for the posterior direction and 55 microm for the resultant 3-D vector length. The corresponding precision at the 95% confidence interval of the test results for repositioning the phantom five times, measured 8.4 microm for the medial direction, 5.5 microm for the superior direction, 16.0 microm for the posterior direction, and 13.5 microm for the resultant 3-D vector length. This in vitro model is proposed as a useful tool for developing a standard for the evaluation of radiostereometric and other radiographic methods used to measure in vivo wear.

  10. Wear resistance and compression strength of ceramics tested in fluoride environments.

    PubMed

    Theodoro, Guilherme Teixeira; Fiorin, Lívia; Moris, Izabela Cristina Maurício; Rodrigues, Renata Cristina Silveira; Ribeiro, Ricardo Faria; Faria, Adriana Cláudia Lapria

    2017-01-01

    Dental ceramics have been widely used because of aesthetic, but wear is still questioned. There are relates that ceramic surface is prone to degradation by acidulated fluoride, that can increase wear rates. The aim of this study was to evaluate the effect of neutral and acidulated fluoride gel, used as preventive agents for professional use, at wear and compression strength of dental ceramics IPS e.max ZirPress (ZIR), IPS Empress Esthetic (EMP) e IPS Inline POM (POM). For this, 30 crowns and 30 disks were obtained by heat-pressing. Crowns and disks were submitted to two-body wear test at machine of mechanical loading, simulating occlusion, lateral movement and disocclusion. It was performed 300,000 cycles at 1Hz frequency under 20N load, to simulate 1 year of mastication. Samples were totally immersed during the test and were divided into three groups according to the gel used for immersion (n=10): control, neutral (sodium fluoride 2%) and acidulated (acidulated phosphate fluoride 1.23%). Samples (crowns and disks) were analyzed for vertical height loss after the test using, respectively, profile projector and stereomicroscope. Roughness of worn surface of crowns and disks was evaluated by laser confocal microscopy. Data of height loss and roughness were evaluated by two-way ANOVA and Bonferroni's test. A crown/disk of each group was analyzed by scanning electronic microscopy. After wear resistance tests, crowns were cemented to their abutments and submitted to compressive load at 30° angulation and 1mm/min speed. Type of failures was compared by qui-square test. Ceramic EMP worn less while ZIR worn more. Control gel worn more at crowns while acidulated gel worn more at disks. Surface roughness of samples tested at acidulated gel was significantly lower. Type of failures found at compression resistance tests was affected by ceramic type, but not by gel used. The results suggest that ceramic and fluoride gel affect wear and roughness of worn surface while type of failure is only affected by ceramic. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Wear of two pit and fissure sealants in contact with primary teeth

    PubMed Central

    Galo, Rodrigo; Contente, Marta Maria Martins Giamatei; Borsatto, Maria Cristina

    2014-01-01

    Objectives: Wear simulations may provide an indication of the clinical performance of pit-and-fissure sealants when associated with primary teeth as counterbody, restricting the involved variables. The aim of this study was to evaluate wear of dental materials used as pit-and-fissure sealants in contact with primary teeth. Materials and Methods: A resinous sealant (Fluroshield®) and a resin-modified glass ionomer cement (Vitremer®) were selected in a post-plate design, using as counterbody primary tooth pins (4 × 4 × 2 mm) at 3 and 10 N vertical load, 1 Hz frequency, 900 wear cycles in artificial saliva (n = 15). Attrition coefficient values were obtained and the material and primary tooth volumes were analyzed. Data were analyzed statistically by ANOVA and Duncan's test (P < 0.05). Results: Fluroshield® presented the highest attrition coefficient values for the 3 N but these values decreased significantly for the 10 N load. The means for volume loss (3 mm) of the different samples after the wear test were not statistically different for the materials. The volume loss values for the primary teeth were statistically different and there was an increase in volume loss with the increase of the load applied in the wear tests. Conclusions: Differences were also observed with regard to the surface deformation characteristics. The wear rates of primary tooth enamel vary according to the type of material and the load applied during mastication. PMID:24966777

  12. Wear performance of neat and vitamin E blended highly cross-linked PE under severe conditions: The combined effect of accelerated ageing and third body particles during wear test.

    PubMed

    Affatato, Saverio; De Mattia, Jonathan Salvatore; Bracco, Pierangiola; Pavoni, Eleonora; Taddei, Paola

    2016-12-01

    The objective of this study is to evaluate the effects of third-body particles on the in vitro wear behaviour of three different sets of polyethylene acetabular cups after prolonged testing in a hip simulator and accelerated ageing. Vitamin E-blended, cross-linked polyethylene (XLPE_VE), cross-linked polyethylene (XLPE) and conventional polyethylene (STD_PE) acetabular cups were simulator tested for two million cycles under severe conditions (i.e. by adding third-body particles to the bovine calf serum lubricant). Micro-Fourier Transform Infrared and micro-Raman spectroscopic analyses, differential scanning calorimetry, and crosslink density measurements were used to characterize the samples at a molecular level. The STD_PE cups had twice mass loss than the XLPE_VE components and four times than the XLPE samples; statistically significant differences were found between the mass losses of the three sets of cups. The observed wear trend was justified on the basis of the differences in cross-link density among the samples (XLPE>XLPE_VE>STD_PE). FTIR crystallinity profiles, bulk DSC crystallinity and surface micro-Raman crystallinity seemed to have a similar behaviour upon testing: all of them (as well as the all-trans and ortho-trans contents) revealed the most significant changes in XLPE and XLPE_VE samples. The more severe third-body wear testing conditions determined more noticeable changes in all spectroscopic markers with respect to previous tests. Unexpectedly, traces of bulk oxidation were found in both STD_PE (unirradiated) and XLPE (remelting-stabilized), which were expected to be stable to oxidation; on the contrary, XLPE_VE demonstrated a high oxidative stability in the present, highly demanding conditions. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. WEAR PROMOTED IN THE APICAL THIRD OF SIMULATED CANALS AFTER INSTRUMENTATION WITH PROTAPER UNIVERSAL SYSTEM

    PubMed Central

    da Silva, Kathrein Tapia; Grazziotin-Soares, Renata; Limongi, Orlando; Irala, Luis Eduardo Duarte; Salles, Alexandre Azevedo

    2009-01-01

    Objective: This study evaluated the wear in the apical third of simulate canals after preparation with ProTaper Universal Rotary System. Material and Methods: 24 sets of instruments were used in 24 simulated canals in transparent epoxy resin blocks with degree of curvature of either 20°or 40°. The canals were photographed preoperatively and after preparation of the apical stop with ProTaper F3, F4 and F5 instruments. The initial and final images were exported to Adobe Photoshop® software and superimposed to detect the root canal wall differences (in mm) between them, in two points located 1 (A) and 5 (B) mm from the point where the working length was established. Data were subjected to analysis of variance to verify the existence of interaction among the factors: canal curvature, instrument size and curve location. Significant level was set at 5%. Results: Regardless of the location and the canal curvature, F4 and F5 instruments produced the greatest wear (p<0.05). Conclusions: There was a deviation from the original pathway towards the outside of the root curvature in both analyzed points. All instruments produced canal transportation, but the F4 and F5 instruments produced more than the other instruments, and should thus be used with care in curved canals. PMID:19936533

  14. Energy and wear optimisation of train longitudinal dynamics and of traction and braking systems

    NASA Astrophysics Data System (ADS)

    Conti, R.; Galardi, E.; Meli, E.; Nocciolini, D.; Pugi, L.; Rindi, A.

    2015-05-01

    Traction and braking systems deeply affect longitudinal train dynamics, especially when an extensive blending phase among different pneumatic, electric and magnetic devices is required. The energy and wear optimisation of longitudinal vehicle dynamics has a crucial economic impact and involves several engineering problems such as wear of braking friction components, energy efficiency, thermal load on components, level of safety under degraded or adhesion conditions (often constrained by the current regulation in force on signalling or other safety-related subsystem). In fact, the application of energy storage systems can lead to an efficiency improvement of at least 10% while, as regards the wear reduction, the improvement due to distributed traction systems and to optimised traction devices can be quantified in about 50%. In this work, an innovative integrated procedure is proposed by the authors to optimise longitudinal train dynamics and traction and braking manoeuvres in terms of both energy and wear. The new approach has been applied to existing test cases and validated with experimental data provided by Breda and, for some components and their homologation process, the results of experimental activities derive from cooperation performed with relevant industrial partners such as Trenitalia and Italcertifer. In particular, simulation results are referred to the simulation tests performed on a high-speed train (Ansaldo Breda Emu V250) and on a tram (Ansaldo Breda Sirio Tram). The proposed approach is based on a modular simulation platform in which the sub-models corresponding to different subsystems can be easily customised, depending on the considered application, on the availability of technical data and on the homologation process of different components.

  15. Recoil-Implantation Of Multiple Radioisotopes Towards Wear Rate Measurements And Particle Tracing In Prosthetic Joints

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Warner, Jacob A.; Timmers, Heiko; Smith, Paul N.

    2011-06-01

    This study demonstrates a new method of radioisotope labeling of ultra-high molecular weight polyethylene inserts in prosthetic joints for wear studies. The radioisotopes {sup 97}Ru, {sup 100}Pd, {sup 100}Rh, and {sup 101m}Rh are produced in fusion evaporation reactions induced by {sup 12}C ions in a {sup 92}Zr target foil. The fusion products recoil-implant into ultra-high molecular weight polyethylene plugs, machined to fit into the surface of the inserts. During laboratory simulations of the joint motion, a wear rate of the labeled polyethylene may be measured and the pathways of wear debris particles can be traced by detecting characteristic gamma-rays. Themore » concentration profiles of the radioisotopes extend effectively uniformly from the polyethylene surface to a depth of about 4 {mu}m. The multiplicity of labeling and the use of several gamma-ray lines aids with avoiding systematic measurement uncertainties. Two polyethylene plugs were labeled and one was fitted into the surface of the tibial insert of a knee prosthesis, which had been worn in. Actuation over close to 100,000 cycles with a 900 N axial load and a 24 deg. flexion angle removed (14{+-}1)% of the gamma-ray activity from the plug. Most of this activity dispersed into the serum lubricant identifying this as the important debris pathway. Less than 1% activity was transferred to the femoral component of the prosthesis and the measured activity on the tibial tray was insignificant. Assuming uniform wear across the superior surface of the insert, a wear rate of (12{+-}3) mm{sup 3}/Megacycle was determined. This is consistent with wear rate measurements under similar conditions using other techniques.« less

  16. Evaluation of tilting disc valves after fatigue life testing: preliminary results within a comparison program.

    PubMed

    Barbaro, V; Boccanera, G; Daniele, C; Grigioni, M; Palombo, A

    1995-09-01

    A fatigue life test, by accelerating the beat rate, simulates several years of virtual life of a prosthetic heart valve in a short period of time. The correlation between the in vivo life of a valve and in vitro testing expectations is as yet not well established, but reproducible test conditions yield precious information about wear and failure. The paper reports a qualitative analysis of mechanical valve wear as part of a comparison program designed to investigate the significance of fatigue testing with the ultimate aim of defining standard guidelines for these type of tests. Two tilting disc valves (29 mm) were subjected to 16 years of fatigue life simulated by means of a Rowan Ash fatigue tester (accelerated rate of 1,200 bpm). Fatigue-induced effects on valve disc and ring surfaces were observed under a monitor microscope to identify wear sites and patterns. A high speed cinematographic system was used to investigate the mechanisms responsible for the wear (wear modes). Valve closure was inspected at a 6,000 frame/s rate. Because of disc rotation during the tilting movement, the points of contact between disc and ring are distributed all around the disc edge but focally on the ring. On both sides of the disc, the surfaces present ring-like concentric grooves. After 16 years of fatigue life the valves showed neither severe wear nor alteration of their fluidodynamic behavior in the pulsatile flow test.

  17. Developing acceptance limits for measured bearing wear of the Space Shuttle Main Engine high pressure oxidizer turbopump

    NASA Technical Reports Server (NTRS)

    Genge, Gary G.

    1991-01-01

    The probabilistic design approach currently receiving attention for structural failure modes has been adapted for obtaining measured bearing wear limits in the Space Shuttle Main Engine high-pressure oxidizer turbopump. With the development of the shaft microtravel measurements to determine bearing health, an acceptance limit was neeed that protects against all known faiure modes yet is not overly conservative. This acceptance criteria limit has been successfully determined using probabilistic descriptions of preflight hardware geometry, empirical bearing wear data, mission requirements, and measurement tool precision as an input for a Monte Carlo simulation. The result of the simulation is a frequency distribution of failures as a function of preflight acceptance limits. When the distribution is converted into a reliability curve, a conscious risk management decision is made concerning the acceptance limit.

  18. Applicability of Macroscopic Wear and Friction Laws on the Atomic Length Scale.

    PubMed

    Eder, S J; Feldbauer, G; Bianchi, D; Cihak-Bayr, U; Betz, G; Vernes, A

    2015-07-10

    Using molecular dynamics, we simulate the abrasion process of an atomically rough Fe surface with multiple hard abrasive particles. By quantifying the nanoscopic wear depth in a time-resolved fashion, we show that Barwell's macroscopic wear law can be applied at the atomic scale. We find that in this multiasperity contact system, the Bowden-Tabor term, which describes the friction force as a function of the real nanoscopic contact area, can predict the kinetic friction even when wear is involved. From this the Derjaguin-Amontons-Coulomb friction law can be recovered, since we observe a linear dependence of the contact area on the applied load in accordance with Greenwood-Williamson contact mechanics.

  19. An in vitro investigation of wear resistance and hardness of composite resins.

    PubMed

    Cao, Liqun; Zhao, Xinyi; Gong, Xu; Zhao, Shouliang

    2013-01-01

    The aim of the present study was to investigate the wear resistance and hardness of five kinds of composite resins. Sixty-five specimens were fabricated with one nano-hybrid (Charisma Diamond), two micro-hybrid (3MZ250, Clearfil AP-X) and two packable (3MP60, Surefil) composite resins, according to a randomized complete block design (n=13, 8 for wear test; 5 for hardness test). The composites were filled in a rectangular mold, and light polymerization. After storage in 37°C deionized water for 24h, all specimens were tested with a custom-made toothbrush machine with a stainless-steel ball as antagonist (3N loads, 1Hz, 6×10(5) cycles) immersed in calcium fluoride slurry. Wear volume, hardness and surface structure of each tested material was examined by a three-dimensional non-contact optical profilometer, Vickers indentation technique and scanning electron microscope. The volume loss ranked from least to most as follows: Charisma Diamond, P60, Z250, Clearfil AP-X and Surefil. Regarding hardness, the rank from highest to lowest as follows: Clearfil AP-X, P60, Surefil, Z250, Charisma Diamond. The interactions between wear resistance and microhardness were not significant. The custom-made machine is considered suitable to simulate sliding of an antagonist cusp on an opposing occlusal composite restoration. Nanofilled composite may have superior wear compared to other composite resins.

  20. Wear of enamel and veneering ceramics after laboratory and chairside finishing procedures.

    PubMed

    Magne, P; Oh, W S; Pintado, M R; DeLong, R

    1999-12-01

    This in vitro study compared the wear of enamel against 3 types of ceramics with high esthetic potential (designed for layering techniques): feldspathic porcelain (Creation), aluminous porcelain (Vitadur alpha), and low-fusing glass (Duceram-LFC). Laboratory finishing (glazing/polishing) and chairside polishing with a Dialite kit were simulated to compare their respective effects on wear. Tooth-material specimen pairs were placed in an artificial mouth using closed-loop servohydraulics. Constant masticatory parameters (13.5 N occlusal force, 0.62 mm lateral excursion; 0.23 second cuspal contact time) were maintained for 300, 000 cycles at a rate of 4 Hz. The occlusal surface of each pair was mapped and digitally recorded before and after each masticatory test. Quantitative changes were measured in terms of depth and volume of wear. Quantitative wear characteristics were assessed by SEM. Significant differences were observed (2-factor ANOVA, P <.05). Duceram-LFC generated increased volume loss of enamel (0.197 mm(3)) compared with Creation (0.135 mm(3)) and Vitadur alpha (0.153 mm(3)). Creation exhibited the lowest ceramic wear and lowest combined volume loss (0.260 mm(3); the sum of the data for enamel and the opposing material) compared with Duceram-LFC (0.363 mm(3)) and Vitadur alpha (0.333 mm(3)). The most significant differences among materials were observed in volume loss, not in depth of wear. For all 3 ceramic systems, qualitative SEM evaluation revealed an abrasive type of wear. Wear characteristics of chairside polished specimens were similar to those of laboratory finished specimens (glazed and polished). Duceram-LFC was the most abrasive ceramic for the antagonistic tooth. Creation ceramic was the least abrasive material and most resistant to wear. Defects, brittleness, and the possibly insufficient toughness of LFC may explain its increased abrasiveness. Laboratory and chairside finishing procedures generated similar results.

  1. Tribological characterisation of Zr-based bulk metallic glass in simulated physiological media

    NASA Astrophysics Data System (ADS)

    Chen, Q.; Chan, K. C.; Liu, L.

    2011-10-01

    Due to their excellent wear resistant properties and high strength, as well as a low Young's modulus, Zr-based bulk metallic glasses (BMGs) are potentially suitable biomaterials for low-friction arthroplasty. The wear characteristics of the Zr60.14Cu22.31Fe4.85Al9.7Ag3 bulk amorphous alloy against ultra-high-molecular-weight polyethylene (UHMWPE) compared to a CoCrMo/UHMWPE combination were investigated in two different wear screening test devices, reciprocating and unidirectional. Hank's solution and sterile calf bovine serum were selected as the lubricant fluid media. It was found that different fluid media had insignificant effect on polyethylene wear against BMG counterfaces. The wear behaviour obtained on both test devices demonstrated that Zr-based BMG achieved UHMWPE counterface wear rates superior to conventional cast CoCrMo alloy, where the wear rate of UHMWPE is decreased by over 20 times. The tribological performance of these joints is superior to that of conventional metal-on-polymer designs. Contact angle measurements suggested that the advantage of BMG over a CoCrMo alloy counterface is attributed to its highly hydrophilic surfaces.

  2. Quantification of in vitro produced wear sites on composite resins using contact profilometry and CCD microscopy: a methodological investigation.

    PubMed

    Koottathape, Natthavoot; Takahashi, Hidekazu; Finger, Wernerj; Kanehira, Masafumi; Iwasaki, Naohiko; Aoyagi, Yujin

    2012-06-01

    Although attritive and abrasive wear of recent composite resins has been substantially reduced, in vitro wear testing with reasonably simulating devices and quantitative determination of resulting wear is still needed. Three-dimensional scanning methods are frequently used for this purpose. The aim of this trial was to compare maximum depth of wear and volume loss of composite samples, evaluated with a contact profilometer and a non-contact CCD camera imaging system, respectively. Twenty-three random composite specimens with wear traces produced in a ball-on-disc sliding device, using poppy seed slurry and PMMA suspension as third-body media, were evaluated with the contact profilometer (TalyScan 150, Taylor Hobson LTD, Leicester, UK) and with the digital CCD microscope (VHX1000, KEYENCE, Osaka, Japan). The target parameters were maximum depth of the wear and volume loss.Results - The individual time of measurement needed with the non-contact CCD method was almost three hours less than that with the contact method. Both, maximum depth of wear and volume loss data, recorded with the two methods were linearly correlated (r(2) > 0.97; p < 0.01). The contact scanning method and the non-contact CCD method are equally suitable for determination of maximum depth of wear and volume loss of abraded composite resins.

  3. Wear Resistance Increase by Friction Stir Processing for Partial Magnesium Replacement in Aluminium Alloys

    NASA Astrophysics Data System (ADS)

    Balos, Sebastian; Labus Zlatanovic, Danka; Janjatovic, Petar; Dramicanin, Miroslav; Rajnovic, Dragan; Sidjanin, Leposava

    2018-03-01

    In this paper, the influence of friction stir processing (FSP) was evaluated as a way of increasing mechanical properties and a way of replacing the magnesium content in aluminium alloys. FSP was done on AA5754 H111 aluminium alloy, containing 3 % Mg, by using various types of tools and different welding speeds, rotational speeds and tilt angles. Wear test was done against SiC abrasive papers. SiC was used to simulate extreme abrasive wear conditions. The wear test was done on untreated AA5754 specimens, processed AA5754 specimens and untreated AA5083 H111 specimens, the latter containing 4.5 % Mg. AA5083 was chosen as an alternative to AA5754, but with a significantly higher Mg content. Base material microhardness was 60 HV1 and 80 HV1 for AA5754 and AA5083 alloys respectively. To find the effect of FSP on AA5754 alloy, microstructures were studied, mainly grain size in the stir zone. It was found, that an elevated processing and rotational speed, without tilt angle and the tool without a reservoir resulted in an increase in hardness of the AA5754 to 70 HV1, but with the occurrence of tunneling defect and the wear rate of 79.3 mg. Lower FSP parameters and a tilted tool with a reservoir resulted in microhardness of 68 HV1 and wear rate of 68.2 mg without tunneling. These wear values are lower than those obtained with unmodified Al-alloys: AA5754 97.2 mg and AA5083 86.3 mg. An increased wear resistance can be attributed to the combined effect of grain boundary strengthening mechanism and solid solution strengthening, versus only the latter in untreated alloys.

  4. EFFECT OF DIFFERENT PROPHYLAXIS METHODS ON SOUND AND DEMINERALIZED ENAMEL

    PubMed Central

    Honório, Heitor Marques; Rios, Daniela; Abdo, Ruy César Camargo; Machado, Maria Aparecida de Andrade Moreira

    2006-01-01

    Considering the importance of professional plaque control for caries prevention, this study comprised an in vitro evaluation of wear by two prophylaxis methods (sodium bicarbonate jet – Profident and pumice and brush) on sound bovine enamel and with artificial carious lesions. Sixty enamel fragments were employed (4x4mm), which were divided into 4 groups: GI – 15 sound blocks treated with pumice and brush; GII – 15 sound blocks treated with Profident; GIII – 15 demineralized blocks treated with pumice and brush, and GIV – 15 demineralized blocks treated with Profident. In the fragments of Groups III and IV, artificial carious lesions were simulated by immersion in 0.05M acetic acid solution 50% saturated with bovine enamel powder at 37oC for 16h. The specimens were submitted to the prophylactic treatments for 10 seconds. Wear analysis was performed by profilometer and revealed the following results: 0.91μm – GI; 0.42μm – GII; 1.6μm – GIII, and 0.94μm – GIV. The two-way ANOVA and Tukey's test (p<0.05) revealed significant difference between all groups. Scanning electron microscopy images were employed to illustrate the wear pattern, with observation of larger alteration on the demineralized enamel surface (GIII; GIV), round-shaped wear on GI and GIII and blasted aspect on GII and GIV. The study indicated that the demineralized enamel presented more wear than the sound enamel, and the brush led to larger wear when compared to Profident. PMID:19089042

  5. Micro-scale abrasive wear behavior of medical implant material Ti-25Nb-3Mo-3Zr-2Sn alloy on various friction pairs.

    PubMed

    Wang, Zhenguo; Huang, Weijiu; Ma, Yanlong

    2014-09-01

    The micro-scale abrasion behaviors of surgical implant materials have often been reported in the literature. However, little work has been reported on the micro-scale abrasive wear behavior of Ti-25Nb-3Mo-3Zr-2Sn (TLM) titanium alloy in simulated body fluids, especially with respect to friction pairs. Therefore, a TE66 Micro-Scale Abrasion Tester was used to study the micro-scale abrasive wear behavior of the TLM alloy. This study covers the friction coefficient and wear loss of the TLM alloy induced by various friction pairs. Different friction pairs comprised of ZrO2, Si3N4 and Al2O3 ceramic balls with 25.4mm diameters were employed. The micro-scale abrasive wear mechanisms and synergistic effect between corrosion and micro-abrasion of the TLM alloy were investigated under various wear-corrosion conditions employing an abrasive, comprised of SiC (3.5 ± 0.5 μm), in two test solutions, Hanks' solution and distilled water. Before the test, the specimens were heat treated at 760°C/1.0/AC+550°C/6.0/AC. It was discovered that the friction coefficient values of the TLM alloy are larger than those in distilled water regardless of friction pairs used, because of the corrosive Hanks' solution. It was also found that the value of the friction coefficient was volatile at the beginning of wear testing, and it became more stable with further experiments. Because the ceramic balls have different properties, especially with respect to the Vickers hardness (Hv), the wear loss of the TLM alloy increased as the ball hardness increased. In addition, the wear loss of the TLM alloy in Hanks' solution was greater than that in distilled water, and this was due to the synergistic effect of micro-abrasion and corrosion, and this micro-abrasion played a leading role in the wear process. The micro-scale abrasive wear mechanism of the TLM alloy gradually changed from two-body to mixed abrasion and then to three-body abrasion as the Vickers hardness of the balls increased. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Enhancement of the Wear Particle Monitoring Capability of Oil Debris Sensors Using a Maximal Overlap Discrete Wavelet Transform with Optimal Decomposition Depth

    PubMed Central

    Li, Chuan; Peng, Juan; Liang, Ming

    2014-01-01

    Oil debris sensors are effective tools to monitor wear particles in lubricants. For in situ applications, surrounding noise and vibration interferences often distort the oil debris signature of the sensor. Hence extracting oil debris signatures from sensor signals is a challenging task for wear particle monitoring. In this paper we employ the maximal overlap discrete wavelet transform (MODWT) with optimal decomposition depth to enhance the wear particle monitoring capability. The sensor signal is decomposed by the MODWT into different depths for detecting the wear particle existence. To extract the authentic particle signature with minimal distortion, the root mean square deviation of kurtosis value of the segmented signal residue is adopted as a criterion to obtain the optimal decomposition depth for the MODWT. The proposed approach is evaluated using both simulated and experimental wear particles. The results show that the present method can improve the oil debris monitoring capability without structural upgrade requirements. PMID:24686730

  7. Enhancement of the wear particle monitoring capability of oil debris sensors using a maximal overlap discrete wavelet transform with optimal decomposition depth.

    PubMed

    Li, Chuan; Peng, Juan; Liang, Ming

    2014-03-28

    Oil debris sensors are effective tools to monitor wear particles in lubricants. For in situ applications, surrounding noise and vibration interferences often distort the oil debris signature of the sensor. Hence extracting oil debris signatures from sensor signals is a challenging task for wear particle monitoring. In this paper we employ the maximal overlap discrete wavelet transform (MODWT) with optimal decomposition depth to enhance the wear particle monitoring capability. The sensor signal is decomposed by the MODWT into different depths for detecting the wear particle existence. To extract the authentic particle signature with minimal distortion, the root mean square deviation of kurtosis value of the segmented signal residue is adopted as a criterion to obtain the optimal decomposition depth for the MODWT. The proposed approach is evaluated using both simulated and experimental wear particles. The results show that the present method can improve the oil debris monitoring capability without structural upgrade requirements.

  8. Superior accuracy of model-based radiostereometric analysis for measurement of polyethylene wear

    PubMed Central

    Stilling, M.; Kold, S.; de Raedt, S.; Andersen, N. T.; Rahbek, O.; Søballe, K.

    2012-01-01

    Objectives The accuracy and precision of two new methods of model-based radiostereometric analysis (RSA) were hypothesised to be superior to a plain radiograph method in the assessment of polyethylene (PE) wear. Methods A phantom device was constructed to simulate three-dimensional (3D) PE wear. Images were obtained consecutively for each simulated wear position for each modality. Three commercially available packages were evaluated: model-based RSA using laser-scanned cup models (MB-RSA), model-based RSA using computer-generated elementary geometrical shape models (EGS-RSA), and PolyWare. Precision (95% repeatability limits) and accuracy (Root Mean Square Errors) for two-dimensional (2D) and 3D wear measurements were assessed. Results The precision for 2D wear measures was 0.078 mm, 0.102 mm, and 0.076 mm for EGS-RSA, MB-RSA, and PolyWare, respectively. For the 3D wear measures the precision was 0.185 mm, 0.189 mm, and 0.244 mm for EGS-RSA, MB-RSA, and PolyWare respectively. Repeatability was similar for all methods within the same dimension, when compared between 2D and 3D (all p > 0.28). For the 2D RSA methods, accuracy was below 0.055 mm and at least 0.335 mm for PolyWare. For 3D measurements, accuracy was 0.1 mm, 0.2 mm, and 0.3 mm for EGS-RSA, MB-RSA and PolyWare respectively. PolyWare was less accurate compared with RSA methods (p = 0.036). No difference was observed between the RSA methods (p = 0.10). Conclusions For all methods, precision and accuracy were better in 2D, with RSA methods being superior in accuracy. Although less accurate and precise, 3D RSA defines the clinically relevant wear pattern (multidirectional). PolyWare is a good and low-cost alternative to RSA, despite being less accurate and requiring a larger sample size. PMID:23610688

  9. Titanium carbide nanoparticles reinforcing nickel matrix for improving nanohardness and fretting wear properties in wet conditions

    NASA Astrophysics Data System (ADS)

    Dănăilă, Eliza; Benea, Lidia; Caron, Nadège; Raquet, Olivier

    2016-09-01

    In this study Ni/nano-TiC functional composite coatings were produced by electro-codeposition of TiC nanoparticles (50 nm mean diameter) with nickel on 304L stainless steel support. Coatings were obtained from a Watts classical solution in which TiC nanoparticles were added. The surface morphology, chemical composition, structure, roughness and thickness, were evaluated in relation to the effect of TiC nanoparticles incorporation into Ni matrix. It was found that incorporation of TiC nanoparticles into the nickel matrix produces morphological changes in the deposit and increases the roughness. The fretting wear behavior in wet conditions of the obtained coatings was evaluated on a ball-on-plate configuration. To evaluate the wet fretting wear (tribocorrosion) behavior the open circuit potential was measured before, during and after the fretting tests at room temperature in the solution that simulates the primary water circuit of Pressurized Water Reactors. The results show that Ni/nano-TiC composite coatings exhibited a low friction coefficient, high nanohardness and fretting wear resistance in wet conditions compared with pure Ni coatings.

  10. Compressor seal rub energetics study

    NASA Technical Reports Server (NTRS)

    Laverty, W. F.

    1978-01-01

    The rub mechanics of compressor abradable blade tip seals at simulated engine conditions were investigated. Twelve statistically planned, instrumented rub tests were conducted with titanium blades and Feltmetal fibermetal rubstrips. The tests were conducted with single stationary blades rubbing against seal material bonded to rotating test disks. The instantaneous rub torque, speed, incursion rate and blade temperatures were continuously measured and recorded. Basic rub parameters (incursion rate, rub depth, abradable density, blade thickness and rub velocity) were varied to determine the effects on rub energy and heat split between the blade, rubstrip surface and rub debris. The test data was reduced, energies were determined and statistical analyses were completed to determine the primary and interactive effects. Wear surface morphology, profile measurements and metallographic analysis were used to determine wear, glazing, melting and material transfer. The rub energies for these tests were most significantly affected by the incursion rate while rub velocity and blade thickness were of secondary importance. The ratios of blade wear to seal wear were representative of those experienced in engine operation of these seal system materials.

  11. Resistance to abrasion of extrinsic porcelain esthetic characterization techniques.

    PubMed

    Chi, Woo J; Browning, William; Looney, Stephen; Mackert, J Rodway; Windhorn, Richard J; Rueggeberg, Frederick

    2017-01-01

    A novel esthetic porcelain characterization technique involves mixing an appropriate amount of ceramic colorants with clear, low-fusing porcelain (LFP), applying the mixture on the external surfaces, and firing the combined components onto the surface of restorations in a porcelain oven. This method may provide better esthetic qualities and toothbrush abrasion resistance compared to the conventional techniques of applying color-corrective porcelain colorants alone, or applying a clear glaze layer over the colorants. However, there is no scientific literature to support this claim. This research evaluated toothbrush abrasion resistance of a novel porcelain esthetic characterization technique by subjecting specimens to various durations of simulated toothbrush abrasion. The results were compared to those obtained using the conventional characterization techniques of colorant application only or colorant followed by placement of a clear over-glaze. Four experimental groups, all of which were a leucite reinforced ceramic of E TC1 (Vita A1) shade, were prepared and fired in a porcelain oven according to the manufacturer's instructions. Group S (stain only) was characterized by application of surface colorants to provide a definitive shade of Vita A3.5. Group GS (glaze over stain) was characterized by application of a layer of glaze over the existing colorant layer as used for Group S. Group SL (stain+LFP) was characterized by application of a mixture of colorants and clear low-fusing add-on porcelain to provide a definitive shade of Vita A3.5. Group C (Control) was used as a control without any surface characterization. The 4 groups were subjected to mechanical toothbrushing using a 1:1 water-to-toothpaste solution for a simulated duration of 32 years of clinical use. The amount of wear was measured at time intervals simulating every 4 years of toothbrushing. These parameters were evaluated longitudinally for all groups as well as compared at similar time points among groups. In this study, the novel external characterization technique (stain+LFP: Group SL) did not significantly enhance the wear resistance against toothbrush abrasion. Instead, the average wear of the applied extrinsic porcelain was 2 to 3 times more than Group S (stain only) and Group GS (glaze over stain). Application of a glaze layer over the colorants (Group GS) showed a significant improvement on wear resistance. Despite its superior physical properties, the leucite reinforced ceramic core (Group C) showed 2 to 4 times more wear when compared with other test groups. A conventional external esthetic characterization technique of applying a glaze layer over the colorants (Group GS) significantly enhanced the surface wear resistance to toothbrush abrasion when compared with other techniques involving application of colorants only (Group S) or mixture of colorant and LFP (Group SL). The underlying core ceramic had significantly less wear resistance compared with all externally characterized specimens. The novel esthetic characterization technique showed more wear and less color stability, and is thus not advocated as the "best" method for surface characterization. Application of a glaze layer provides a more wear-resistant surface from toothbrush abrasion when adjusting or extrinsically characterizing leucite reinforced ceramic restorations. Without the glaze layer, the restoration is subjected to a 2 to 4 times faster rate and amount of wear leading to possible shade mismatch.

  12. Piloting Augmented Reality Technology to Enhance Realism in Clinical Simulation.

    PubMed

    Vaughn, Jacqueline; Lister, Michael; Shaw, Ryan J

    2016-09-01

    We describe a pilot study that incorporated an innovative hybrid simulation designed to increase the perception of realism in a high-fidelity simulation. Prelicensure students (N = 12) cared for a manikin in a simulation lab scenario wearing Google Glass, a wearable head device that projected video into the students' field of vision. Students reported that the simulation gave them confidence that they were developing skills and knowledge to perform necessary tasks in a clinical setting and that they met the learning objectives of the simulation. The video combined visual images and cues seen in a real patient and created a sense of realism the manikin alone could not provide.

  13. Erosive Wear Characterization of Materials for Lunar Construction

    NASA Technical Reports Server (NTRS)

    Mpagazehe, Jeremiah N.; Street, Kenneth W., Jr.; Delgado, Irebert R.; Higgs, C. Fred, III

    2012-01-01

    NASA s Apollo missions revealed that exhaust from the retrorockets of landing spacecraft may act to significantly accelerate lunar dust on the surface of the Moon. A recent study by Immer et al. (C. Immer, P.T. Metzger, P.E. Hintze, A. Nick, and R. Horan, Apollo 12 Lunar Module exhaust plume impingement on Lunar Surveyor III, Icarus, Vol. 211, pp. 1089-1102, 2011) investigated coupons returned to Earth from the Surveyor III lunar probe which were subjected to lunar dust impingement by the Apollo 12 Lunar Module landing. Their study revealed that even with indirect impingement, the spacecraft sustained erosive damage from the fast-moving lunar dust particles. In this work, results are presented from a series of erosive wear experiments performed on 6061 Aluminum using the JSC-1AF lunar dust simulant. Optical profilometry was used to investigate the surface after the erosion process. It was found that even short durations of lunar dust simulant impacting at low velocities produced substantial changes in the surface.

  14. c-axis preferential orientation of hydroxyapatite accounts for the high wear resistance of the teeth of black carp (Mylopharyngodon piceus)

    PubMed Central

    Fu, Jimin; He, Chong; Xia, Biao; Li, Yan; Feng, Qiong; Yin, Qifang; Shi, Xinghua; Feng, Xue; Wang, Hongtao; Yao, Haimin

    2016-01-01

    Biological armors such as mollusk shells have long been recognized and studied for their values in inspiring novel designs of engineering materials with higher toughness and strength. However, no material is invincible and biological armors also have their rivals. In this paper, our attention is focused on the teeth of black carp (Mylopharyngodon piceus) which is a predator of shelled mollusks like snails and mussels. Nanoscratching test on the enameloid, the outermost layer of the teeth, indicates that the natural occlusal surface (OS) has much higher wear resistance compared to the other sections. Subsequent X-ray diffraction analysis reveals that the hydroxyapatite (HAp) crystallites in the vicinity of OS possess c-axis preferential orientation. The superior wear resistance of black carp teeth is attributed to the c-axis preferential orientation of HAp near the OS since the (001) surface of HAp crystal, which is perpendicular to the c-axis, exhibits much better wear resistance compared to the other surfaces as demonstrated by the molecular dynamics simulation. Our results not only shed light on the origin of the good wear resistance exhibited by the black carp teeth but are of great value to the design of engineering materials with better abrasion resistance. PMID:27001150

  15. Cornering and wear characteristics of the Space Shuttle Orbiter nose-gear tire

    NASA Technical Reports Server (NTRS)

    Davis, Pamela A.; Stubbs, Sandy M.; Vogler, William A.

    1989-01-01

    Tests of the Space Shuttle Orbiter nose-gear tire have been completed at NASA Langley's Aircraft Landing Dynamics Facility. The purpose of these tests was to determine the cornering and wear characteristics of the Space Shuttle Orbiter nose-gear tire under realistic operating conditions. The tire was tested on a simulated Kennedy Space Center runway surface at speeds from 100 to 180 kts. The results of these tests defined the cornering characteristics which included side forces and associated side force friction coefficient over a range of yaw angles from 0 deg to 12 deg. Wear characteristics were defined by tire tread and cord wear over a yaw angle range of 0 deg to 4 deg under dry and wet runway conditions. Wear characteristics were also defined for a 15 kt crosswind landing with two blown right main-gear tires and nose-gear steering engaged.

  16. Effects of crystal refining on wear behaviors and mechanical properties of lithium disilicate glass-ceramics.

    PubMed

    Zhang, Zhenzhen; Guo, Jiawen; Sun, Yali; Tian, Beimin; Zheng, Xiaojuan; Zhou, Ming; He, Lin; Zhang, Shaofeng

    2018-05-01

    The purpose of this study is to improve wear resistance and mechanical properties of lithium disilicate glass-ceramics by refining their crystal sizes. After lithium disilicate glass-ceramics (LD) were melted to form precursory glass blocks, bar (N = 40, n = 10) and plate (N = 32, n = 8) specimens were prepared. According to the differential scanning calorimetry (DSC) of precursory glass, specimens G1-G4 were designed to form lithium disilicate glass-ceramics with different crystal sizes using a two-step thermal treatment. In the meantime, heat-pressed lithium disilicate glass-ceramics (GC-P) and original ingots (GC-O) were used as control groups. Glass-ceramics were characterized using X-ray diffraction (XRD) and were tested using flexural strength test, nanoindentation test and toughness measurements. The plate specimens were dynamically loaded in a chewing simulator with 350 N up to 2.4 × 10 6 loading cycles. The wear analysis of glass-ceramics was performed using a 3D profilometer after every 300,000 wear cycles. Wear morphologies and microstructures were analyzed by scanning electron microscopy (SEM). One-way analysis of variance (ANOVA) was used to analyze the data. Multiple pairwise comparisons of means were performed by Tukey's post-hoc test. Materials with different crystal sizes (p < 0.05) exhibited different properties. Specifically, G3 with medium-sized crystals presented the highest flexural strength, hardness, elastic modulus and fracture toughness. G1 and G2 with small-sized crystals showed lower flexural strength, whereas G4, GC-P, and GC-O with large-sized crystals exhibited lower hardness and elastic modulus. The wear behaviors of all six groups showed running-in wear stage and steady wear stage. G3 showed the best wear resistance while GC-P and GC-O exhibited the highest wear volume loss. After crystal refining, lithium disilicate glass-ceramic with medium-sized crystals showed the highest wear resistance and mechanical properties. Copyright © 2018 Elsevier Ltd. All rights reserved.

  17. Shuttle landing runway modification to improve tire spin-up wear performance

    NASA Technical Reports Server (NTRS)

    Daugherty, Robert H.; Yager, Thomas J.; Stubbs, Sandy M.

    1988-01-01

    This paper presents the results of a series of tire spin-up wear tests on a simulated Kennedy Space Center (KSC) runway that were carried out to investigate the tire wear problem for Space Shuttle landings on the KSC runway and to test several modifications of the runway surface designed to alleviate the problem. It was found that the runway surface produced by a concrete smoothing machine using cutters spaced one and three-quarters blades per centimeter provided adequate wet cornering while limiting spin-up wear. Based on the test results, the KSC runway was smoothed for about 1066 m at each end, leaving the original high friction surface, for better wet steering and braking, in the 2438-m central section.

  18. Surface roughness model based on force sensors for the prediction of the tool wear.

    PubMed

    de Agustina, Beatriz; Rubio, Eva María; Sebastián, Miguel Ángel

    2014-04-04

    In this study, a methodology has been developed with the objective of evaluating the surface roughness obtained during turning processes by measuring the signals detected by a force sensor under the same cutting conditions. In this way, the surface quality achieved along the process is correlated to several parameters of the cutting forces (thrust forces, feed forces and cutting forces), so the effect that the tool wear causes on the surface roughness is evaluated. In a first step, the best cutting conditions (cutting parameters and radius of tool) for a certain quality surface requirement were found for pieces of UNS A97075. Next, with this selection a model of surface roughness based on the cutting forces was developed for different states of wear that simulate the behaviour of the tool throughout its life. The validation of this model reveals that it was effective for approximately 70% of the surface roughness values obtained.

  19. Effect of SnO2/SiO2 nano particle dispersant on the performance characteristic of complex multi-doped composite coating produced through electrodeposition on oil and gas storage tap

    NASA Astrophysics Data System (ADS)

    Anawe, P. A. L.; Fayomi, O. S. I.; Ayoola, A. A.; Popoola, A. P. I.

    2018-06-01

    The effect of SnO2/SiO2 nano particle dispersant on the performance characteristic of complex zinc multi-doped composite coating produced through electrodeposition is studied. The degradation behaviour in term of wear and chemical corrosion activities were considered as a major factor in service. The wear mass loss was carried out with the help of reciprocating tester. The electrochemical corrosion characteristics were investigated using linear polarization technique in 3.5% simulated sodium chloride media. The outcome of the analysis shows that the developed coating was seen to provide a sound anti wear characteristics in its multidoped state. The corrosion resistance properties were observed to be massive compared to the binary based sample. It is expected that this characteristic will impact on the performance life span of storage tap in oil and gas.

  20. Improvement in the assessment of wear of total knee replacements using coordinate-measuring machine techniques.

    PubMed

    Blunt, L A; Bills, P J; Jiang, X-Q; Chakrabarty, G

    2008-04-01

    Total joint replacement is one of the most common elective surgical procedures performed worldwide, with an estimate of 1.5x 10(6) operations performed annually. Currently joint replacements are expected to function for 10-15 years; however, with an increase in life expectancy, and a greater call for knee replacement due to increased activity levels, there is a requirement to improve their function to offer longer-term improved quality of life for patients. Wear analysis of total joint replacements has long been an important means in determining failure mechanisms and improving longevity of these devices. The effectiveness of the coordinate-measuring machine (CMM) technique for assessing volumetric material loss during simulated life testing of a replacement knee joint has been proved previously by the present authors. The purpose of the current work is to present an improvement to this method for situations where no pre-wear data are available. To validate the method, simulator tests were run and gravimetric measurements taken throughout the test, such that the components measured had a known wear value. The implications of the results are then discussed in terms of assessment of joint functionality and development of standardized CMM-based product standards. The method was then expanded to allow assessment of clinically retrieved bearings so as to ascertain a measure of true clinical wear.

  1. Polyurethane as a potential knee hemiarthroplasty biomaterial: an in-vitro simulation of its tribological performance.

    PubMed

    Luo, Y; McCann, L; Ingham, E; Jin, Z-M; Ge, S; Fisher, J

    2010-01-01

    Hemiarthroplasty is an attractive alternative to total joint replacement for the young active patient, when only one side of the synovial joint is damaged. In the development of a hemiarthroplasty prosthesis, a comprehensive understanding of the tribology of both the natural joint and the hemireplaced joint is necessary. The objectives of this study were to investigate the tribological response of polyurethane (PU) as a potential hemiarthroplasty material. Bovine medial compartmental knees were tested in a Prosim pendulum friction simulator, which applied physiologically relevant loading and motion. The healthy medial compartment was investigated as a negative control; a stainless steel hemiarthroplasty was investigated as a positive control; and three PU hemiarthroplasty plates of different moduli (1.4 MPa, 6.5 MPa, and 22 MPa) were also investigated. Using the lower-modulus PU caused reduced levels of contact stress and friction shear stress, which resulted in reduced levels of opposing cartilage wear. The two PU bearings with the lowest moduli demonstrated a similar tribological performance to the negative control. The higher-modulus PU (22 MPa) did demonstrate higher levels of friction shear stress, and wear resulted on the opposing cartilage, although not as severe as the wear from the stainless steel group. This study supports the use of compliant PU designs in future tribological experiments and hemiarthroplasty design applications.

  2. Influence of different toothpaste abrasives on the bristle end-rounding quality of toothbrushes.

    PubMed

    de Oliveira, G J P L; de Aveiro, J M; Pavone, C; Marcantonio, R A C

    2015-02-01

    To evaluate the influence of different toothpaste abrasives on the bristle wear and bristle tip morphology of toothbrushes with different degrees of hardness. Ninety samples of bovine incisor teeth were used in this study. The samples were randomly divided into three groups according to the bristle hardness of the toothbrush used: soft bristles (S); extra-soft bristles (ES); hard bristles (H). The toothbrushes of each group were randomly divided into six subgroups with five toothbrushes each, according to the abrasive of the toothpaste used in the simulation: Negative control (distilled water); toothpaste 1 (silica); toothpaste 2 (hydrated silica); toothpaste 3 (calcium carbonate, calcium bicarbonate and silica); toothpaste 4 (tetrapotassium pyrophosphate, silica and titanium dioxide); toothpaste 5 (calcium carbonate). The samples were placed in a toothbrushing simulating machine that simulating three months of brushing. The toothbrush bristles were evaluated by the bristle wear index, and the bristle tips morphology was evaluated by the bristle tip morphology index. The ES brush presented the highest bristle wear among the toothbrushes. Additionally, the S brushes showed better morphology of the bristles followed by ES and H brushes. The type of abrasive only influenced the bristle tip morphology of the ES brushes. The toothpaste 3 induced the worse bristle tip morphology than all the other toothpastes. Different abrasives have influence only on the bristle tip morphology of the ES brushes. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. Simulation of long-term fatigue damage in bioprosthetic heart valves: effects of leaflet and stent elastic properties

    PubMed Central

    Martin, Caitlin

    2014-01-01

    One of the major failure modes of bioprosthetic heart valves (BHVs) is noncalcific structural deterioration due to fatigue of the tissue leaflets; yet, the mechanisms of fatigue are not well understood. BHV durability is primarily assessed based on visual inspection of the leaflets following accelerated wear testing. In this study, we developed a computational framework to simulate BHV leaflet fatigue, which is both efficient and quantitative, making it an attractive alternative to traditional accelerated wear testing. We utilize a phenomenological soft tissue fatigue damage model developed previously to describe the stress softening and permanent set of the glutaraldehyde-treated bovine pericardium leaflets in BHVs subjected to cyclic loading. A parametric study was conducted to determine the effects of altered leaflet and stent elastic properties on the fatigue of the leaflets. The simulation results show that heterogeneity of the leaflet elastic properties, poor leaflet coaptation, and little stent-tip deflection may accelerate leaflet fatigue, which agrees with clinical findings. Therefore, the developed framework may be an invaluable tool for evaluating leaflet durability in new tissue valve designs, including traditional BHVs as well as new transcatheter valves. PMID:24092257

  4. Investigation of the Effect of Tool Edge Geometry upon Cutting Variables, Tool Wear and Burr Formation Using Finite Element Simulation — A Progress Report

    NASA Astrophysics Data System (ADS)

    Sartkulvanich, Partchapol; Al-Zkeri, Ibrahim; Yen, Yung-Chang; Altan, Taylan

    2004-06-01

    This paper summarizes some of the progress made on FEM simulations of metal cutting processes conducted at the Engineering Research Center (ERC/NSM). Presented research focuses on the performance of various cutting edge geometries (hone and chamfer edges) for different tool materials and specifically on: 1) the effect of round and chamfer edge geometries on the cutting variables in machining carbon steels and 2) the effect of the edge hone size upon the flank wear and burr formation behavior in face milling of A356-T6 aluminum alloy. In the second task, an innovative design of edge preparation with varying hone size around the tool nose is also explored using FEM. In order to model three-dimensional conventional turning and face milling with two-dimensional orthogonal cutting simulations, 2D simulation cross-sections consisting of the cutting speed direction and chip flow direction are selected at different locations along the tool nose radius. Then the geometries of the hone and chamfer edges and their associated tool angles as well as uncut chip thickness are determined on these planes and employed in cutting simulations. The chip flow direction on the tool rake face are obtained by examining the wear grooves on the experimental inserts or estimated by using Oxley's approximation theory of oblique cutting. Simulation results are compared with the available experimental results (e.g. cutting forces) both qualitatively and quantitatively.

  5. Wear versus Thickness and Other Features of 5-Mrad Crosslinked UHMWPE Acetabular Liners

    PubMed Central

    Shen, Fu-Wen; Lu, Zhen

    2010-01-01

    Background The low wear rates of crosslinked polyethylenes provide the potential to use larger diameters to resist dislocation. However, this requires the use of thinner liners in the acetabular component, with concern that higher contact stresses will increase wear, offsetting the benefits of the crosslinking. Questions/purposes We asked the following questions: Is the wear of conventional and crosslinked polyethylene liners affected by ball diameter, rigidity of backing, and liner thickness? Are the stresses in the liner affected by thickness? Methods Wear rates were measured in a hip simulator and stresses were calculated using finite element modeling. Results Without crosslinking, the wear rate was 4% to 10% greater with a 36-mm diameter than a 28-mm diameter. With crosslinking, wear was 9% lower with a 36-mm diameter without metal backing and 4% greater with metal backing. Reducing the thickness from 6 mm to 3 mm increased the contact stress by 46%, but the wear rate decreased by 19%. Conclusions The reduction in wear with 5 Mrad of crosslinking was not offset by increasing the diameter from 28 mm to 36 mm or by using a liner as thin as 3 mm. Clinical Relevance The results indicate, for a properly positioned 5-Mrad crosslinked acetabular component and within the range of dimensions evaluated, neither wear nor stresses in the polyethylene are limiting factors in the use of larger-diameter, thinner cups to resist dislocation. PMID:20848244

  6. Wear-caused deflection evolution of a slide rail, considering linear and non-linear wear models

    NASA Astrophysics Data System (ADS)

    Kim, Dongwook; Quagliato, Luca; Park, Donghwi; Murugesan, Mohanraj; Kim, Naksoo; Hong, Seokmoo

    2017-05-01

    The research presented in this paper details an experimental-numerical approach for the quantitative correlation between wear and end-point deflection in a slide rail. Focusing the attention on slide rail utilized in white-goods applications, the aim is to evaluate the number of cycles the slide rail can operate, under different load conditions, before it should be replaced due to unacceptable end-point deflection. In this paper, two formulations are utilized to describe the wear: Archard model for the linear wear and Lemaitre damage model for the nonlinear wear. The linear wear gradually reduces the surface of the slide rail whereas the nonlinear one accounts for the surface element deletion (i.e. due to pitting). To determine the constants to use in the wear models, simple tension test and sliding wear test, by utilizing a designed and developed experiment machine, have been carried out. A full slide rail model simulation has been implemented in ABAQUS including both linear and non-linear wear models and the results have been compared with those of the real rails under different load condition, provided by the rail manufacturer. The comparison between numerically estimated and real rail results proved the reliability of the developed numerical model, limiting the error in a ±10% range. The proposed approach allows predicting the displacement vs cycle curves, parametrized for different loads and, based on a chosen failure criterion, to predict the lifetime of the rail.

  7. An in vitro investigation of wear resistance and hardness of composite resins

    PubMed Central

    Cao, Liqun; Zhao, Xinyi; Gong, Xu; Zhao, Shouliang

    2013-01-01

    Purpose: The aim of the present study was to investigate the wear resistance and hardness of five kinds of composite resins. Materials and Methods: Sixty-five specimens were fabricated with one nano-hybrid (Charisma Diamond), two micro-hybrid (3MZ250, Clearfil AP-X) and two packable (3MP60, Surefil) composite resins, according to a randomized complete block design (n=13, 8 for wear test; 5 for hardness test). The composites were filled in a rectangular mold, and light polymerization. After storage in 37°C deionized water for 24h, all specimens were tested with a custom-made toothbrush machine with a stainless-steel ball as antagonist (3N loads, 1Hz, 6×105 cycles) immersed in calcium fluoride slurry. Wear volume, hardness and surface structure of each tested material was examined by a three-dimensional non-contact optical profilometer, Vickers indentation technique and scanning electron microscope. Results: The volume loss ranked from least to most as follows: Charisma Diamond, P60, Z250, Clearfil AP-X and Surefil. Regarding hardness, the rank from highest to lowest as follows: Clearfil AP-X, P60, Surefil, Z250, Charisma Diamond. The interactions between wear resistance and microhardness were not significant. Conclusions: The custom-made machine is considered suitable to simulate sliding of an antagonist cusp on an opposing occlusal composite restoration. Nanofilled composite may have superior wear compared to other composite resins. PMID:23844265

  8. Views of STS-4 crew during a training session in the SMS

    NASA Technical Reports Server (NTRS)

    1982-01-01

    Views of STS-4 crew during a training session in the Shuttle Mission Simulator (SMS). Astronaut Henry W. Hartsfield, Jr., STS-4 pilot, takes part in training session wearing an ejection/escape (EES) spacesuit and helmet (31368); Astronaut Thomas K. (Ken) Mattingly, II., STS-4 crew commander, takes part in training session wearing an ejection/escape suit (31369).

  9. Effects of bionic units on the fatigue wear of gray cast iron surface with different shapes and distributions

    NASA Astrophysics Data System (ADS)

    Chen, Zhi-kai; Lu, Shu-chao; Song, Xi-bin; Zhang, Haifeng; Yang, Wan-shi; Zhou, Hong

    2015-03-01

    To improve the fatigue wear resistance of gray cast iron (GCI), GCI samples were modified by a laser to imitate the unique structure of some soil animals alternating between soft and hard phases; the hard phase resists the deformation and the soft phase releases the deformation. Using the self-controlled fatigue wear test method, the fatigue wear behaviors of treated and untreated samples were investigated and compared experimentally. The results show that the bionic non-smooth surface obtains a beneficial effect on improving the fatigue wear resistance of a sample, and the fatigue wear resistance of the bionic sample assembled with reticulate units (60°+0°), whose mass loss was reduced by 62%, was superior to the others. Meanwhile, a finite element (FE) was used to simulate the compression and the distributions of strain and stress on the non-smooth surface was inferred. From these results, we understood that the functions of the bionic unit such as reducing strain and stress, and also obstructing the closure and propagation of cracks were the main reasons for improving the fatigue wear property of GCI.

  10. Scanning Electron Microscopy and Energy-Dispersive X-Ray Spectroscopy as a Valuable Tool to Investigate the Ultra-High-Molecular-Weight Polyethylene Wear Mechanisms and Debris in Hip Implants.

    PubMed

    Schappo, Henrique; Gindri, Izabelle M; Cubillos, Patrícia O; Maru, Marcia M; Salmoria, Gean V; Roesler, Carlos R M

    2018-01-01

    The use of scanning electron microscopy (SEM) and energy-dispersive spectrometry (EDS) was investigated to understand the wear mechanisms from a metal-on-polyethylene bearing couple. Morphological features of femoral head acetabular liner, and isolated particles resulting from hip wear testing were evaluated. EDS was proposed to investigate the polymeric nature of the particles isolated from the wear testing. In this work, 28-mm conventional ultra-high-molecular-weight polyethylene acetabular liners paired with metallic heads were tested in a hip wear simulator over 2 million cycles. SEM-EDS was employed to investigate wear mechanisms on hip implant components and associated wear debris. SEM showed worn surfaces for both hip components, and a significant volume of ultra-high-molecular-weight polyethylene wear particles resulting from hip wear testing. Particles were classified into 3 groups, which were then correlated to wear mechanisms. Group I had particles with smooth surfaces, group II consisted of particles with rough surfaces, and group III comprised aggregate-like particles. Group I EDS revealed that particles from groups I and II had a high C/O ratio raising a concern about the particle source. On the other hand, particles from group III had a low C/O ratio, supporting the hypothesis that they resulted from the wear of acetabular liner. Most of particles identified in group III were in the biologically active size range (0.3 to 20 μm). The use of optical and electron microscopy enabled the morphological characterization of worn surfaces and wear debris, while EDS was essential to elucidate the chemical composition of isolated debris. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Toothbrush abrasion, simulated tongue friction and attrition of eroded bovine enamel in vitro.

    PubMed

    Vieira, A; Overweg, E; Ruben, J L; Huysmans, M C D N J M

    2006-05-01

    Enamel erosion results in the formation of a softened layer that is susceptible to disruption by mechanical factors such as brushing abrasion, tongue friction and attrition. The aim of this study was to investigate the individual contribution of those mechanical insults to the enamel loss caused by dental erosion. Forty two bovine enamel samples were randomly divided into seven groups (n=6 per group) that were submitted to 3cycles of one of the following regimes: erosion and remineralization (er/remin); toothbrush abrasion and remineralization (abr/remin); erosion, toothbrush abrasion and remineralization (er/abr/remin); attrition and remineralization (at/remin); erosion, attrition and remineralization (er/at/remin); simulated tongue friction and remineralization (tg/remin); erosion, simulated tongue friction and remineralization (er/tg/remin). Erosion took place in a demineralization solution (50mM citric acid, pH 3) for 10min under agitation. Brushing abrasion, tongue friction and attrition were simulated for 1min using a home-made wear device. Remineralization was carried out in artificial saliva for 2h. Enamel loss was quantified using optical profilometry. One-way ANOVA indicated a significant difference between the amounts of enamel lost due to the different wear regimes (p

  12. Dynamic simulation of the effect of soft toric contact lenses movement on retinal image quality.

    PubMed

    Niu, Yafei; Sarver, Edwin J; Stevenson, Scott B; Marsack, Jason D; Parker, Katrina E; Applegate, Raymond A

    2008-04-01

    To report the development of a tool designed to dynamically simulate the effect of soft toric contact lens movement on retinal image quality, initial findings on three eyes, and the next steps to be taken to improve the utility of the tool. Three eyes of two subjects wearing soft toric contact lenses were cyclopleged with 1% cyclopentolate and 2.5% phenylephrine. Four hundred wavefront aberration measurements over a 5-mm pupil were recorded during soft contact lens wear at 30 Hz using a complete ophthalmic analysis system aberrometer. Each wavefront error measurement was input into Visual Optics Laboratory (version 7.15, Sarver and Associates, Inc.) to generate a retinal simulation of a high contrast log MAR visual acuity chart. The individual simulations were combined into a single dynamic movie using a custom MatLab PsychToolbox program. Visual acuity was measured for each eye reading the movie with best cycloplegic spectacle correction through a 3-mm artificial pupil to minimize the influence of the eyes' uncorrected aberrations. Comparison of the simulated acuity was made to values recorded while the subject read unaberrated charts with contact lenses through a 5-mm artificial pupil. For one study eye, average acuity was the same as the natural contact lens viewing condition. For the other two study eyes visual acuity of the best simulation was more than one line worse than natural viewing conditions. Dynamic simulation of retinal image quality, although not yet perfect, is a promising technique for visually illustrating the optical effects on image quality because of the movements of alignment-sensitive corrections.

  13. Heat strain evaluation of overt and covert body armour in a hot and humid environment.

    PubMed

    Pyke, Andrew J; Costello, Joseph T; Stewart, Ian B

    2015-03-01

    The aim of this study was to elucidate the thermophysiological effects of wearing lightweight non-military overt and covert personal body armour (PBA) in a hot and humid environment. Eight healthy males walked on a treadmill for 120 min at 22% of their heart rate reserve in a climate chamber simulating 31 °C (60%RH) wearing either no armour (control), overt or covert PBA in addition to a security guard uniform, in a randomised controlled crossover design. No significant difference between conditions at the end of each trial was observed in core temperature, heart rate or skin temperature (P > 0.05). Covert PBA produced a significantly greater amount of body mass change (-1.81 ± 0.44%) compared to control (-1.07 ± 0.38%, P = 0.009) and overt conditions (-1.27 ± 0.44%, P = 0.025). Although a greater change in body mass was observed after the covert PBA trial; based on the physiological outcome measures recorded, the heat strain encountered while wearing lightweight, non-military overt or covert PBA was negligible compared to no PBA. The wearing of bullet proof vests or body armour is a requirement of personnel engaged in a wide range of occupations including police, security, customs and even journalists in theatres of war. This randomised controlled crossover study is the first to examine the thermophysiological effects of wearing lightweight non-military overt and covert personal body armour (PBA) in a hot and humid environment. We conclude that the heat strain encountered while wearing both overt and covert lightweight, non-military PBA was negligible compared to no PBA. Copyright © 2014 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  14. Does cyclic stress and accelerated ageing influence the wear behavior of highly crosslinked polyethylene?

    PubMed

    Affatato, Saverio; De Mattia, Jonathan Salvatore; Bracco, Pierangiola; Pavoni, Eleonora; Taddei, Paola

    2016-06-01

    First-generation (irradiated and remelted or annealed) and second-generation (irradiated and vitamin E blended or doped) highly crosslinked polyethylenes were introduced in the last decade to solve the problems of wear and osteolysis. In this study, the influence of the Vitamin-E addition on crosslinked polyethylene (XLPE_VE) was evaluated by comparing the in vitro wear behavior of crosslinked polyethylene (XLPE) versus Vitamin-E blended polyethylene XLPE and conventional ultra-high molecular weight polyethylene (STD_PE) acetabular cups, after accelerated ageing according to ASTM F2003-02 (70.0±0.1°C, pure oxygen at 5bar for 14 days). The test was performed using a hip joint simulator run for two millions cycles, under bovine calf serum as lubricant. Mass loss was found to decrease along the series XLPE_VE>STD_PE>XLPE, although no statistically significant differences were found between the mass losses of the three sets of cups. Micro-Raman spectroscopy was used to investigate at a molecular level the morphology changes induced by wear. The spectroscopic analyses showed that the accelerated ageing determined different wear mechanisms and molecular rearrangements during testing with regards to the changes in both the chain orientation and the distribution of the all-trans sequences within the orthorhombic, amorphous and third phases. The results of the present study showed that the addition of vitamin E was not effective to improve the gravimetric wear of PE after accelerated ageing. However, from a molecular point of view, the XLPE_VE acetabular cups tested after accelerated ageing appeared definitely less damaged than the STD_PE ones and comparable to XLPE samples. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. Views of STS-5 crew during a training session in the SMS

    NASA Technical Reports Server (NTRS)

    1982-01-01

    Views of STS-5 crew during a training session in the Shuttle Mission Simulator (SMS). Astronaut Robert F. Overmyer, STS-5 pilot, participates in training session wearing a communications kit assembly (ASSY). He is dressed in regular flight suit and is studying flight documentation.

  16. Integrated experimental and theoretical approach for corrosion and wear evaluation of laser surface nitrided, Ti-6Al-4V biomaterial in physiological solution.

    PubMed

    Vora, Hitesh D; Shanker Rajamure, Ravi; Dahotre, Sanket N; Ho, Yee-Hsien; Banerjee, Rajarshi; Dahotre, Narendra B

    2014-09-01

    A laser based surface nitriding process was adopted to further enhance the osseo-integration, corrosion resistance, and tribological properties of the commonly used bioimplant alloy, Ti-6Al-4V. Earlier preliminary osteoblast, electrochemical, and corrosive wear studies of laser nitrided titanium in simulated body fluid clearly revealed improvement of cell adhesion as well as enhancement in corrosion and wear resistance but mostly lacked the in-depth fundamental understanding behind these improvements. Therefore, a novel integrated experimental and theoretical approach were implemented to understand the physical phenomena behind the improvements and establish the property-structure-processing correlation of nitrided surface. The first principle and thermodynamic calculations were employed to understand the thermodynamic, electronic, and elastic properties of TiN for enthalpy of formation, Gibbs free energy, density of states, and elastic properties of TiN were investigated. Additionally, open circuit potential and cyclic potentio-dynamic polarization tests were carried out in simulated body fluid to evaluate the corrosion resistance that in turn linked with the experimentally measured and computationally predicted surface energies of TiN. From these results, it is concluded that the enhancement in the corrosion resistance after laser nitriding is mainly attributed to the presence of covalent bonding via hybridization among Ti (p) and N (d) orbitals. Furthermore, mechanical properties, such as, Poisson׳s ratio, stiffness, Pugh׳s ductility criteria, and Vicker׳s hardness, predicted from first principle calculations were also correlated to the increase in wear resistance of TiN. All the above factors together seem to have contributed to significant improvement in both wear and corrosion performance of nitride surface compared to the bare Ti-6Al-4V in physiological environment indicating its suitability for bioimplant applications. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. An in vitro simulation model to assess the severity of edge loading and wear, due to variations in component positioning in hip joint replacements.

    PubMed

    O'Dwyer Lancaster-Jones, O; Williams, S; Jennings, L M; Thompson, J; Isaac, G H; Fisher, J; Al-Hajjar, M

    2017-09-23

    The aim of this study was to develop a preclinical in vitro method to predict the occurrence and severity of edge loading condition associated with the dynamic separation of the centres of the head and cup (in the absence of impingement) for variations in surgical positioning of the cup. Specifically, this study investigated the effect of both the variations in the medial-lateral translational mismatch between the centres of the femoral head and acetabular cup and the variations in the cup inclination angles on the occurrence and magnitude of the dynamic separation, the severity of edge loading, and the wear rate of ceramic-on-ceramic hip replacement bearings in a multi-station hip joint simulator during a walking gait cycle. An increased mismatch between the centres of rotation of the femoral head and acetabular cup resulted in an increased level of dynamic separation and an increase in the severity of edge loading condition which led to increased wear rate in ceramic-on-ceramic bearings. Additionally for a given translational mismatch, an increase in the cup inclination angle gave rise to increased dynamic separation, worst edge loading conditions, and increased wear. To reduce the occurrence and severity of edge loading, the relative positions (the mismatch) of the centres of rotation of the head and the cup should be considered alongside the rotational position of the acetabular cup. This study has considered the combination of mechanical and tribological factors for the first time in the medial-lateral axis only, involving one rotational angle (inclination) and one translational mismatch. © 2017 The Authors Journal of Biomedical Materials Research Part B: Applied Biomaterials Published by Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2017. © 2017 The Authors Journal of Biomedical Materials Research Part B: Applied Biomaterials Published by Wiley Periodicals, Inc.

  18. Analysis of the Effects of Surface Pitting and Wear on the Vibrations of a Gear Transmission System

    NASA Technical Reports Server (NTRS)

    Choy, F. K.; Polyshchuk, V.; Zakrajsek, J. J.; Handschuh, R. F.; Townsend, D. P.

    1994-01-01

    A comprehensive procedure to simulate and analyze the vibrations in a gear transmission system with surface pitting, 'wear' and partial tooth fracture of the gear teeth is presented. An analytical model was developed where the effects of surface pitting and wear of the gear tooth were simulated by phase and magnitude changes in the gear mesh stiffness. Changes in the gear mesh stiffness were incorporated into each gear-shaft model during the global dynamic simulation of the system. The overall dynamics of the system were evaluated by solving for the transient dynamics of each shaft system simultaneously with the vibration of the gearbox structure. In order to reduce the number of degrees-of-freedom in the system, a modal synthesis procedure was used in the global transient dynamic analysis of the overall transmission system. An FFT procedure was used to transform the averaged time signal into the frequency domain for signature analysis. In addition, the Wigner-Ville distribution was also introduced to examine the gear vibration in the joint time frequency domain for vibration pattern recognition. Experimental results obtained from a gear fatigue test rig at NASA Lewis Research Center were used to evaluate the analytical model.

  19. Development of chair-side evaluation system of swallowing discomfort of denture wearers

    NASA Astrophysics Data System (ADS)

    Matsumoto, Keisuke; Ikuta, Ryuhei; Kataoka, Kanako; Ono, Yumie; Tamaki, Katsushi

    2018-02-01

    We investigated the appropriate hemodynamic parameters of functional near-infrared spectroscopy (fNIRS) to best differentiate the discomfort intensity related to swallowing in healthy subjects wearing different types of simulated dentures. Thirty-one subjects performed 4 sessions of water-swallowing task in a sitting position without or with wearing any one of the 3 simulated dentures under continuous fNIRS monitoring of the prefrontal cortex. The simulated dentures were consisted of a flat maxillary palatal bar and bilateral support attachment to the teeth and gum. The palatal bar positions were arranged along with the anterior, middle, or posterior areas of the upper jaw. The cumulative values of oxyhemoglobin and deoxyhemoglobin concentration changes were calculated for periods of 5 - 10 s from completion of swallowing. Subjective rating of swallowing-discomfort was the lowest without wearing denture and increased along with the palatal bar position placed from anterior to posterior. Cumulated deoxyhemoglobin signals calculated for 10 s post-swallowing event in the left frontopolar prefrontal cortex showed the best correlation with the subjective rating of discomfort in swallowing with dentures. These neurological signatures would be beneficial to detect swallowing discomfort in elderly denture wearers who have difficulty in communicating with dentists.

  20. In Vitro Wear Resistance of Nano-Hybrid Composite Denture Teeth.

    PubMed

    Munshi, Nabeel; Rosenblum, Marc; Jiang, Shuying; Flinton, Robert

    2017-04-01

    To evaluate the wear resistance of nano-hybrid composite denture teeth as compared to two commonly used denture teeth: interpenetrating polymer network (IPN) and double crosslinking polymethylmethacrylate (PMMA) denture teeth. 18 styli and 18 disk specimens were prepared from the three denture tooth materials: nano-hybrid composite, IPN, and double crosslinking PMMA. The specimens were mounted in a two-body wear testing machine to simulate chewing in the complete denture. The amount of wear from the styli specimens were measured before and after using a digital micrometer, and the depth of the wear track from the disk specimens was measured using a noncontact 3D optical profilometer. The total wear from each denture tooth group was compared using one-way ANOVA with a 0.05 significance level. A Tukey post hoc test was used to determine differences between the three groups. The mean total wear in the nano-hybrid composite teeth group was 1.16 mm, SD = 0.5 mm, statistically significantly higher (p ≤ 0.0001) than the IPN (mean = 0.13 mm, SD = 0.05) and double crosslinking PMMA tooth groups (mean = 0.31 mm, SD = 0.19). There was no statistically significant difference between IPN denture teeth and double crosslinking PMMA denture teeth in the amount of wear. Nano-hybrid composite denture teeth exhibited statistically significantly more wear than the IPN and double crosslinking PMMA denture teeth. © 2015 by the American College of Prosthodontists.

  1. Estimation of appropriate lubricating film thickness in ceramic-on-ceramic hip prostheses

    NASA Astrophysics Data System (ADS)

    Tauviqirrahman, M.; Muchammad, Bayuseno, A. P.; Ismail, R.; Saputra, E.; Jamari, J.

    2016-04-01

    Artificial hip prostheses, consisting of femoral head and acetabular cup are widely used and have affected the lives of many people.However, the primary issue associated with the long term performance of hip prostheses is loosening induced by excessive wear during daily activity. Therefore, an effective lubrication is necessary to significantly decrease the wear. To help understand the lubricating performance of such typical hip joint prostheses, in the present paper a hydrodynamic lubrication model based on Reynolds equationwas introduced. The material pairs of ceramic acetabular cup against ceramic femoral head was investegated.The main aim of this study is to investigate of the effect of loading on the formation of lubricating film thickness.The model of a ball-in-socket configuration was considered assuming that the cup was stationary while the ball was to rotate at a steady angular velocityvarying loads.Based on simulation result, it was found that to promote fluid film lubrication and prevent the contacting components leading to wear, the film thickness of lubricant should be determined carefully based on the load applied. This finding may have useful implication in predicting the failure of lubricating synovial fluid film and wear generation in hip prostheses.

  2. Polycyclic aromatic hydrocarbons, elemental and organic carbon emissions from tire-wear.

    PubMed

    Aatmeeyata; Sharma, Mukesh

    2010-09-15

    Tire-wear is an important source of PAHs, elemental carbon (EC) and organic carbon (OC). The emissions of these pollutants have been studied in an experimental set-up, simulating a realistic road-tire interaction (summer tire-concrete road). The large particle non-exhaust emissions (LPNE; diameter greater than 10 microm) have been evaluated over 14,500 km run of the tire. An increasing linear trend with cumulative km run was observed for emissions of PAHs and carbon. Amongst PAHs in LPNE, pyrene has been observed to be the highest (30+/-4 mg kg(-1)) followed by benzo[ghi]perylene (17+/-2 mg kg(-1)). Different fractions of EC-OC for tire-wear have been analyzed, and unlike exhaust emissions, EC1 was observed to be 99% of EC whereas more than 70% of the OC was the high temperature carbon (OC3 and OC4). The overall emission factors (mass tire(-1) km(-1)) for PAHs, EC and OC from tire-wear are 378 ng tire(-1) km(-1), 1.46 mg tire(-1) km(-1) and 2.37 mg tire(-1) km(-1) for small cars. Copyright 2010 Elsevier B.V. All rights reserved.

  3. Wear resistance and mechanisms of composite hardfacings at abrasive impact erosion wear

    NASA Astrophysics Data System (ADS)

    Surzhenkov, A.; Viljus, M.; Simson, T.; Tarbe, R.; Saarna, M.; Casesnoves, F.

    2017-05-01

    Tungsten carbide based hardmetal containing sprayed and melted composite hardfacings are prospective for protection against abrasive wear. For selection of abrasive wear resistant hardfacings under intensive impact wear conditions, both mechanical properties (hardness, fracture toughness, etc.) and abrasive wear conditions (type of abrasive, impact velocity, etc.) should be considered. This study focuses on the wear (wear rate and mechanisms) of thick metal-matrix composite hardfacings with hardmetal (WC-Co) reinforcement produced by powder metallurgy technology. The influence of the hardmetal reinforcement type on the wear resistance at different abrasive impact erosion wear (AIEW) conditions was studied. An optimal reinforcement for various wear conditions is described. Based on wear mechanism studies, a mathematical model for wear prediction was drafted.

  4. Wear of liquid nitrogen-cooled 440C bearing steels in an oxygen environment

    NASA Technical Reports Server (NTRS)

    Chaudhuri, Dilip K.; Verma, Ravi

    1988-01-01

    This paper presents up-to-date findings of the research being conducted to understand the mechanism of sliding wear in unlubricated 440C bearing steels under oxidative conditions. A sliding wear test rig has been designed and built with a cylinder-on-flat geometry. The equipment is capable of testing specimens under high axial loads and sliding speeds in a simulated LOX environment. Samples of 440C steel, quenched and tempered to a hardness of Rc 56, were tested under a load of 890 N and a sliding speed of 2.05 m/sec for total sliding distances of up to 5.54 km. Flash temperatures during these tests were measured with an IR camera and a fast digital recorder. Microstructural and microanalytical data from the worn surfaces and the debris particles are analyzed extensively, along with wear rates, flash temperatures, surface profiles, hardnesses, and residual stresses, in the context of oxidation and wear theories.

  5. The influence of dental alloys on three-body wear of human enamel and dentin in an inlay-like situation.

    PubMed

    Graf, K; Johnson, G H; Mehl, A; Rammelsberg, P

    2002-01-01

    This in vitro study evaluated the effect of metal alloys on three-body wear resistance of enamel and dentin, and vice versa. Three-body wear of human enamel, dentin, a soft gold alloy (BiOcclus Inlay), a CoCr alloy (Remanium 2000), a resin cement (Variolink II) and a zinc oxide phosphate cement (Harvard) was investigated using the ACTA-machine. Sample chambers of eight sample wheels were prepared with pure materials or combinations of human tooth substance, alloys and cement, simulating an inlay-like situation. After 100,000 and 200,000 cycles in a millet suspension with a spring force of 20 N, the amount of abraded material was profilometrically measured and evaluated by 3D surface data analysis. After 200,000 cycles, the materials demonstrated a mean loss of 0.41 microm for CoCr, 51 microm for gold, 57 microm for enamel, 164 microm for dentin, 79 microm for Variolink and 369 microm for Harvard. Using ANOVA and the Games-Howell-test, resin cement, enamel and gold were a subset not shown to differ, as was zinc phosphate cement and dentin. CoCr demonstrated the least wear and differed significantly from all materials. Enamel wear was significantly reduced in mixed chambers with CoCr, and gold after 200,000 cycles compared to enamel in pure chambers. In summary, a soft gold alloy can be recommended for inlays when considering three-body abrasion since the wear rate of the "soft" gold alloy corresponded to that of human enamel.

  6. Effectiveness of a novel mobile health education intervention (Peek) on spectacle wear among children in India: study protocol for a randomized controlled trial.

    PubMed

    Morjaria, Priya; Bastawrous, Andrew; Murthy, Gudlavalleti Venkata Satyanarayana; Evans, Jennifer; Gilbert, Clare

    2017-04-08

    Uncorrected refractive errors are the commonest cause of visual loss in children despite spectacle correction being highly cost-effective. Many affected children do not benefit from correction as a high proportion do not wear their spectacles. Reasons for non-wear include parental attitudes, overprescribing and children being teased/bullied. Most school programmes do not provide health education for affected children, their peers, teachers or parents. The Portable Eye Examination Kit (Peek) will be used in this study. Peek has applications for measuring visual acuity with software for data entry and sending automated messages to inform providers and parents. Peek also has an application which simulates the visual blur of uncorrected refractive error (SightSim). The hypothesis is that higher proportion of children with uncorrected refractive errors in schools allocated to the Peek educational package will wear their spectacles 3-4 months after they are dispensed, and a higher proportion of children identified with other eye conditions will access services, compared with schools receiving standard school screening. Cluster randomized, double-masked trial of children with and without uncorrected refractive errors or other eye conditions. Government schools in Hyderabad, India will be allocated to intervention (Peek) or comparator (standard programme) arms before vision screening. In the intervention arm Peek will be used for vision screening, SightSim images will be used in classroom teaching and will be taken home by children, and voice messages will be sent to parents of children requiring spectacles or referral. In both arms the same criteria for recruitment, prescribing and dispensing spectacles will be used. After 3-4 months children dispensed spectacles will be followed up to assess spectacle wear, and uptake of referrals will be ascertained. The cost of developing and delivering the Peek package will be assessed. The cost per child wearing their spectacles or accessing services will be compared. Educating parents, teachers and children about refractive errors and the importance of wearing spectacles has the potential to increase spectacle wear amongst children. Innovative, potentially scalable mobile technology (Peek) will be used to screen, provide health education, track spectacle wear and adherence to follow-up amongst children referred. Controlled-Trials.com, ISRCTN78134921 . Registered on 29 June 2016.

  7. Investigations of the effects of particle properties on the wear resistance of the particle reinforced composites using a novel wear model

    NASA Astrophysics Data System (ADS)

    Prabhu, T. Ram

    2016-08-01

    A wear model is developed based on the discrete lattice spring-mass approach to study the effects of particle volume fraction, size, and stiffness on the wear resistance of particle reinforced composites. To study these effects, we have considered three volume fractions (10%, 20% and 30%), two sizes (10 × 10 and 4 × 4 sites), and two different stiffness of particles embedded in the matrix in a regular pattern. In this model, we have discretized the composite system (400 × 100 sites) into the lumped masses connected with interaction spring elements in two dimensions. The interaction elements are assumed as linear elastic and ideal plastic under applied forces. Each mass is connected to its first and second nearest neighbors by springs. The matrix and particles sites are differentiated by choosing the different stiffness values. The counter surface is simulated as a rigid body that moves on the composite material at a constant sliding speed along the horizontal direction. The governing equations are formed by equating the spring force between the pair of sites given by Hooke’s law plus external contact forces and the force due to the motion of the site given by the equation of motion. The equations are solved for the plastic strain accumulated in the springs using an explicit time stepping procedure based on a finite difference form of the above equations. If the total strain accumulated in the spring elements connected to a lump mass site exceeds the failure strain, the springs are considered to be broken, and the mass site is removed or worn away from the lattice and accounts as a wear loss. The model predicts that (i) increasing volume fraction, reducing particle size and increasing particle stiffness enhance the wear resistance of the particle reinforced composites, (ii) the particle stiffness is the most significant factor affecting the wear resistance of the composites, and (iii) the wear resistance reduced above the critical volume fraction (Vc), and Vc increases with increasing particle size. Finally, we have qualitatively compared the model results with our previously published experimental results to prove the effectiveness of the model to analysis the complex wear systems.

  8. Fault Wear by Damage Evolution During Steady-State Slip

    NASA Astrophysics Data System (ADS)

    Lyakhovsky, Vladimir; Sagy, Amir; Boneh, Yuval; Reches, Ze'ev

    2014-11-01

    Slip along faults generates wear products such as gouge layers and cataclasite zones that range in thickness from sub-millimeter to tens of meters. The properties of these zones apparently control fault strength and slip stability. Here we present a new model of wear in a three-body configuration that utilizes the damage rheology approach and considers the process as a microfracturing or damage front propagating from the gouge zone into the solid rock. The derivations for steady-state conditions lead to a scaling relation for the damage front velocity considered as the wear-rate. The model predicts that the wear-rate is a function of the shear-stress and may vanish when the shear-stress drops below the microfracturing strength of the fault host rock. The simulated results successfully fit the measured friction and wear during shear experiments along faults made of carbonate and tonalite. The model is also valid for relatively large confining pressures, small damage-induced change of the bulk modulus and significant degradation of the shear modulus, which are assumed for seismogenic zones of earthquake faults. The presented formulation indicates that wear dynamics in brittle materials in general and in natural faults in particular can be understood by the concept of a "propagating damage front" and the evolution of a third-body layer.

  9. Tribological Behavior of Plasma-Sprayed Al2O3-20 wt.%TiO2 Coating

    NASA Astrophysics Data System (ADS)

    Cui, Shiyu; Miao, Qiang; Liang, Wenping; Zhang, Zhigang; Xu, Yi; Ren, Beilei

    2017-05-01

    Al2O3-20 wt.% TiO2 ceramic coatings were deposited on the surface of Grade D steel by plasma spraying of commercially available powders. The phases and the microstructures of the coatings were investigated by x-ray diffraction and scanning electron microscopy, respectively. The Al2O3-20 wt.% TiO2 composite coating exhibited a typical inter-lamellar structure consisting of the γ-Al2O3 and the Al2TiO5 phases. The dry sliding wear behavior of the coating was examined at 20 °C using a ball-on-disk wear tester. The plasma-sprayed coating showed a low wear rate ( 4.5 × 10-6 mm3 N-1 m-1), which was <2% of that of the matrix ( 283.3 × 10-6 mm3 N-1 m-1), under a load of 15 N. In addition, the tribological behavior of the plasma-sprayed coating was analyzed by examining the microstructure after the wear tests. It was found that delamination of the Al2TiO5 phase was the main cause of the wear during the sliding wear tests. A suitable model was used to simulate the wear mechanism of the coating.

  10. Radiostethoscopes: an innovative solution for auscultation while wearing protective gear.

    PubMed

    Candiotti, Keith A; Rodriguez, Yiliam; Curia, Luciana; Saltzman, Bruce; Shekhter, Ilya; Rosen, Lisa; Birnbach, David J

    2011-01-01

    To demonstrate a radiostethoscope that could be modified and successfully used while wearing protective gear to solve the problem of auscultation in a hazardous material or infectious disease setting. This study was a randomized, prospective, and blinded investigation. The study was conducted at the University of Miami-Jackson Memorial Hospital Center for Patient Safety. Two blinded anesthesiologists using a radiostethoscope performed a total of 100 assessments (50 each) to evaluate endotracheal tube position on a human patient simulator (HPS). Each lung of the HPS was ventilated separately using a double lumen tube. Four ventilation patterns (ie, right lung ventilation only; left lung ventilation only; ventilation of both lungs; and an esophageal intubation or no breath sounds) were simulated. The ventilation pattern was determined randomly and participants were blinded. An Ambu-Bag was used for ventilation. An assistant moved the radiostethoscope to the right and left lung fields and then to the abdomen of the HPS while ventilating. Subjects had to identify the ventilation pattern after listening to all three locations. A third member of the research team collected responses. Each subject, who wore both types of respirator (positive and negative), performed a total of 25 trials. Participants later compared the two types of respirators and their ability to auscultate for breath sounds. Subjects were able to verify the correct ventilation pattern in all attempts (100 percent). Radiostethoscopes appear to provide a viable solution for the problem of patient auscultation while wearing protective gear.

  11. Gas Gun Studies of Interface Wear Effects

    NASA Astrophysics Data System (ADS)

    Jackson, Tyler; Kennedy, Greg; Thadhani, Naresh

    2011-06-01

    The characteristics of interface wear were studied by performing gas gun experiments at velocities up to 1 km/s. The approach involved developing coefficients of constitutive strength models for Al 6061 and OFHC-Cu, then using those to design die geometry for interface wear gas gun experiments. Taylor rod-on-anvil impact experiments were performed to obtain coefficients of the Johnson-Cook constitutive strength model by correlating experimentally obtained deformed states of impacted samples with those predicted using ANSYS AUTODYN hydrocode. Simulations were used with validated strength models to design geometry involving acceleration of Al rods through a copper concentric cylindrical angular extrusion die. Experiments were conducted using 7.62 mm and 80 mm diameter gas guns. Differences in the microstructure of the interface layer and microhardness values illustrate that stress-strain conditions produced during acceleration of Al through the hollow concentric copper die, at velocities less than 800 m/s, result in formation of a layer via solid state alloying due to severe plastic deformation, while higher velocities produce an interface layer consisting of melted and re-solidified aluminum.

  12. The effects of wearing Passenger Protective Breathing Equipment on evacuation times through type III and type IV emergency aircraft exits in clear air and smoke.

    DOT National Transportation Integrated Search

    1989-11-01

    The effects of Passenger Protective Breathing Equipment (PPBE) on the time required for simulated emergency evacuations through Type III and Type IV overwing aircraft exits were studied in two quasi-independent experiments, one in clear air and anoth...

  13. Automation of wear analysis for large caliber weapons

    NASA Astrophysics Data System (ADS)

    Salafia, Dominick; DeLeon, Norberto L.; Outlaw, James F.

    1999-12-01

    As part of the Test and Evaluation Command (TECOM) the Metrology and Simulation Division (MT-MS) at the U.S. Army Yuma Proving Ground (USAYPG) has the mission to measure and record the wear effects of conventional and experimental munitions on large caliber weapons. The primary objective is to ensure that the weapon to be fired will safely meet the mission requirements for the quantity and energy of the munitions under live fire testing. Currently, there are two criteria used to "deadline" a weapon. One is the actual physical wear tolerance. The other relates to the energy (zone) expended by the round and the subsequent fatigue induced in the microstructure of the gun tube. The latter is referred to as the Equivalent Full Charge (EFC) for the particular round. In order to maximize safety and reduce the time required to manually search records for the appropriate level of useful life, the Measurements and Simulation Branch of MT-MS at USAYPG has made use of the installation network such that critical information may be accessed from the local area network or the Internet. An electronic database has been constructed and the query routines have been written so that systems test personnel, test directors (TD), and other government organizations may conduct a search for a particular weapon. The user may enter specifications such as percent physical life, percent EFC life, caliber, model, modifications, and serial number or any combination thereof. This paper is intended to inform the engineering and scientific community, engaged in weapons performance evaluation using simulations and field testing, of the existence of wear analysis automation for large caliber weapons.

  14. STS-26 MS Nelson on fixed based (FB) shuttle mission simulator (SMS) middeck

    NASA Technical Reports Server (NTRS)

    1988-01-01

    STS-26 Discovery, Orbiter Vehicle (OV) 103, Mission Specialist (MS) George D. Nelson trains on the middeck of the fixed based (FB) shuttle mission simulator (SMS). Nelson, wearing communications assembly headset, adjusts camera mounting bracket.

  15. A novel tribological study on DLC-coated micro-dimpled orthopedics implant interface.

    PubMed

    Choudhury, Dipankar; Urban, Filip; Vrbka, Martin; Hartl, Martin; Krupka, Ivan

    2015-05-01

    This study investigates a tribological performance of diamond like carbon (DLC) coated micro dimpled prosthesis heads against ceramic cups in a novel pendulum hip joint simulator. The simulator enables determining friction coefficient and viscous effects of a concave shaped specimen interface (conformal contact). Two types of DLC such as hydrogenated amorphous carbon (a-C:H) and tetrahedral amorphous carbon (Ta-C) and one set of micro dimple (diameter of 300µm, depth of 70µm, and pitch of 900µm) were fabricated on metallic prosthesis heads. The experiment results reveal a significant friction coefficient reduction to the 'dimpled a-C:H/ceramic' prosthesis compared to a 'Metal (CoCr)/ceramic' prosthesis because of their improved material and surface properties and viscous effect. The post-experiment surface analysis displays that the dimpled a-C:H yielded a minor change in the surface roughness, and generated a larger sizes of wear debris (40-200nm sized, equivalent diameter), a size which could be certainly stored in the dimple, thus likely to reducing their possible third body abrasive wear rate. Thus, dimpled a:C-H can be used as a 'metal on ceramic hip joint interface', whereas the simulator can be utilized as an advanced bio-tribometer. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. Surface Roughness Model Based on Force Sensors for the Prediction of the Tool Wear

    PubMed Central

    de Agustina, Beatriz; Rubio, Eva María; Sebastián, Miguel Ángel

    2014-01-01

    In this study, a methodology has been developed with the objective of evaluating the surface roughness obtained during turning processes by measuring the signals detected by a force sensor under the same cutting conditions. In this way, the surface quality achieved along the process is correlated to several parameters of the cutting forces (thrust forces, feed forces and cutting forces), so the effect that the tool wear causes on the surface roughness is evaluated. In a first step, the best cutting conditions (cutting parameters and radius of tool) for a certain quality surface requirement were found for pieces of UNS A97075. Next, with this selection a model of surface roughness based on the cutting forces was developed for different states of wear that simulate the behaviour of the tool throughout its life. The validation of this model reveals that it was effective for approximately 70% of the surface roughness values obtained. PMID:24714391

  17. Origins of Folding Instabilities on Polycrystalline Metal Surfaces

    NASA Astrophysics Data System (ADS)

    Beckmann, N.; Romero, P. A.; Linsler, D.; Dienwiebel, M.; Stolz, U.; Moseler, M.; Gumbsch, P.

    2014-12-01

    Wear and removal of material from polycrystalline metal surfaces is inherently connected to plastic flow. Here, plowing-induced unconstrained surface plastic flow on a nanocrystalline copper surface has been studied by massive molecular dynamics simulations and atomic force microscopy scratch experiments. In agreement with experimental findings, bulges in front of a model asperity develop into vortexlike fold patterns that mark the disruption of laminar flow. We identify dislocation-mediated plastic flow in grains with suitably oriented slip systems as the basic mechanism of bulging and fold formation. The observed folding can be fundamentally explained by the inhomogeneity of plasticity on polycrystalline surfaces which favors bulge formation on grains with suitably oriented slip system. This process is clearly distinct from Kelvin-Helmholtz instabilities in fluids, which have been previously suggested to resemble the formed surface fold patterns. The generated prow grows into a rough chip with stratified lamellae that are identified as the precursors of wear debris. Our findings demonstrate the importance of surface texture and grain structure engineering to achieve ultralow wear in metals.

  18. Dr. von Braun Tries Out the Neutral Buoyancy Simulator (NBS)

    NASA Technical Reports Server (NTRS)

    1967-01-01

    Marshall Space Flight Center (MSFC) Director, Dr. von Braun, is shown leaving the suiting-up van wearing a pressure suit prepared for a tryout in the MSFC Neutral Buoyancy Simulator (NBS). Weighted to a neutrally buoyant condition, Dr. von Braun was able to perform tasks underwater which simulated weightless conditions found in space.

  19. Development of superconducting high gradient magnetic separation system for highly viscous fluid for practical use

    NASA Astrophysics Data System (ADS)

    Hayashi, S.; Mishima, F.; Akiyama, Y.; Nishijima, S.

    2011-11-01

    In the industrial plants processing highly viscous fluid such as foods or industrial products, it is necessary to remove the metallic wear debris originating from pipe in manufacturing line which triggers quality loss. In this study, we developed a high gradient magnetic separation (HGMS) system which consists of superconducting magnet to remove the metallic wear debris. The magnetic separation experiment and the particle trajectory simulation were conducted with polyvinyl alcohol (PVA) as a model material (viscosity coefficient was 10 Pa s, which is 10,000 times higher than that in water). In order to develop a magnetic separation system for practical use, the particle trajectory simulation by using solenoidal superconducting magnet was conducted, and the possibility of the magnetic separation for removing ferromagnetic stainless steel (SUS) particles in highly viscous fluid of 10 Pa s was indicated. Based on the results, the number of filters to obtain required separation efficiency was examined to design the practical separation system.

  20. Wear behaviour of the couple polyethylene Ti6Al4V: Effects of the metallic surface preparation and nitrogen implantation

    NASA Astrophysics Data System (ADS)

    Martinella, R.; Giovanardi, S.; Palombarini, G.; Corchia, M.; Delogu, P.; Giorgi, R.; Tosello, C.

    The wear behaviour improvement of the tribological couple Ti6Al4V-UHMWPE is of great interest to the medical field. Wear tests were carried out in water on a reciprocating UHMWPE annulus on implanted Ti6Al4V disc tribotestcr, with loads and velocities simulating those of hip joints. A comparison of wear behaviours was also carried out between untreated Ti6Al4V samples and Ti6Al4V subjected to a special lapping procedure. UHMWPE worn against ion-implanted and especially lapped Ti alloy showed the lowest wear rate, while, the highest (about one order of magnitude) was shown by the UHMWPE against untreated Ti6Al4V samples. XPS and AES surface analyses were carried out on metallic discs to examine the chemical composition of the surface before wear tests. Moreover depth distribution of nitrogen in implanted samples was determined using the same techniques. SEM observations displayed a polyethylene transfer film on all metallic surfaces, particularly on untreated Ti6Al4V samples. A discussion about uselessness of more conventional surface treatments for the Ti alloy is also reported.

  1. A Novel Method to Assess Wear Rates of Retrieved Tibial Inserts Following in-vivo Use

    NASA Astrophysics Data System (ADS)

    Paniogue, Tanille J.

    Ultra-high molecular weight polyethylene (UHMWPE) on cobalt chrome is the bearing couple of choice for total knee arthroplasty. The number of patients undergoing total knee arthroplasty has been steadily growing and is projected to continue increasing rapidly in the near future. Many of these patients are younger and more active and therefore need a longer lasting device. However, many of these devices fail prematurely and often the primary reason for failure and ultimately revision is due to wear related issues. Therefore, examining how wear rates of the UHMWPE tibial insert change during in-vivo use can help elucidate the mechanisms of accelerated wear and hopefully aid in finding solutions to combat wear related failures. Different crosslinking treatments have been employed by manufacturers to improve wear resistance of the polyethylene. While this has been shown to be an effective way to reduce wear, crosslinking has led to other issues such as oxidative instability and a decline in mechanical properties. The purpose of this body of work is to examine how changes in oxidation, after in-vivo use, affect wear resistance. A novel testing method was developed to test the native articular surface from retrieved tibial inserts in a laboratory Pin-on-Disk (POD) simulator. The method was validated using short-duration implant articular surfaces and non-articular control pins. In the absence of high surface oxidation or severe surface damage, the articular surface pins had comparable steady state wear rates to their bulk counterparts. Tests of devices with longer in-vivo service show chemical changes consistent with a free-radical mediated oxidation mechanism. Tribological assessment of the articular surfaces shows increasing wear rates as a function of oxidation. While this relationship has been hypothesized in the literature, these experiments represent the first physical demonstration of the phenomenon. The wear mechanism is further explored through infrared spectroscopy, assessment of the wear scar, and documentation of evolution of the contact surfaces in the articulation.

  2. Friction and wear properties of novel HDPE--HAp--Al2O3 biocomposites against alumina counterface.

    PubMed

    Bodhak, Subhadip; Nath, Shekhar; Basu, Bikramjit

    2009-03-01

    In an effort to enhance physical properties of biopolymers (high-density polyethylene, HDPE) in terms of elastic modulus and hardness, various ceramic fillers, like alumina (Al2O3) and hydroxyapatite (HAp) are added, and therefore it is essential to assess the friction and wear resistance properties of HDPE biocomposites. In this perspective, HDPE composites with varying ceramic filler content (upto 40 vol%) were fabricated under the optimal compression molding conditions and their friction and wear properties were evaluated against Al2O3 at fretting contacts. All the experiments were conducted at a load of 10 N for duration of 100,000 cycles in both dry as well as simulated body fluid (SBF). Such planned set of experiments has been designed to address three important issues: (a) whether the improvement in physical properties (hardness, E-modulus) will lead to corresponding improvement in friction and wear properties; (b) whether the fretting in SBF will provide sufficient lubrication in order to considerably enhance the tribological properties, as compared to that in ambient conditions; and (c) whether the generation of wear debris particles be reduced for various compositionally modified polymer composites, in comparison to unreinforced HDPE. The experimental results indicate the possibility of achieving extremely low coefficient of friction (COF approximately 0.047) as well as higher wear resistance (wear rate in the order of approximately 10(-7) mm3 N(-1) m(-1)) with the newly developed composites in SBF. A low wear depth of 3.5-4 microm is recorded, irrespective of fretting environment. Much effort has been put forward to correlate the friction and wear mechanisms with abrasion, adhesion, and wear debris formation.

  3. High frequency circular translation pin-on-disk method for accelerated wear testing of ultrahigh molecular weight polyethylene as a bearing material in total hip arthroplasty.

    PubMed

    Saikko, Vesa

    2015-01-21

    The temporal change of the direction of sliding relative to the ultrahigh molecular weight polyethylene (UHMWPE) component of prosthetic joints is known to be of crucial importance with respect to wear. One complete revolution of the resultant friction vector is commonly called a wear cycle. It was hypothesized that in order to accelerate the wear test, the cycle frequency may be substantially increased if the circumference of the slide track is reduced in proportion, and still the wear mechanisms remain realistic and no overheating takes place. This requires an additional slow motion mechanism with which the lubrication of the contact is maintained and wear particles are conveyed away from the contact. A three-station, dual motion high frequency circular translation pin-on-disk (HF-CTPOD) device with a relative cycle frequency of 25.3 Hz and an average sliding velocity of 27.4 mm/s was designed. The pins circularly translated at high frequency (1.0 mm per cycle, 24.8 Hz, clockwise), and the disks at low frequency (31.4mm per cycle, 0.5 Hz, counter-clockwise). In a 22 million cycle (10 day) test, the wear rate of conventional gamma-sterilized UHMWPE pins against polished CoCr disks in diluted serum was 1.8 mg per 24 h, which was six times higher than that in the established 1 Hz CTPOD device. The wear mechanisms were similar. Burnishing of the pin was the predominant feature. No overheating took place. With the dual motion HF-CTPOD method, the wear testing of UHMWPE as a bearing material in total hip arthroplasty can be substantially accelerated without concerns of the validity of the wear simulation. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. Eddy current NDE performance demonstrations using simulation tools

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maurice, L.; Costan, V.; Guillot, E.

    2013-01-25

    To carry out performance demonstrations of the Eddy-Current NDE processes applied on French nuclear power plants, EDF studies the possibility of using simulation tools as an alternative to measurements on steam generator tube mocks-up. This paper focuses on the strategy led by EDF to assess and use code{sub C}armel3D and Civa, on the case of Eddy-Current NDE on wears problem which may appear in the U-shape region of steam generator tubes due to the rubbing of anti-vibration bars.

  5. Computational wear assessment of hard on hard hip implants subject to physically demanding tasks.

    PubMed

    Nithyaprakash, R; Shankar, S; Uddin, M S

    2018-05-01

    Hip implants subject to gait loading due to occupational activities are potentially prone to failures such as osteolysis and aseptic loosening, causing painful revision surgeries. Highly risky gait activities such as carrying a load, stairs up or down and ladder up or down may cause excessive loading at the hip joint, resulting in generation of wear and related debris. Estimation of wear under the above gait activities is thus crucial to design and develop a new and improved implant component. With this motivation, this paper presents an assessment of wear generation of PCD-on-PCD (poly crystalline diamond) hip implants using finite element (FE) analysis. Three-dimensional (3D) FE model of hip implant along with peak gait and peak flexion angle for each activity was used to estimate wear of PCD for 10 million cycles. The maximum and minimum initial contact pressures of 206.19 MPa and 151.89 MPa were obtained for carrying load of 40 kg and sitting down or getting up activity. The simulation results obtained from finite element model also revealed that the maximum linear wear of 0.585 μm occurred for the patients frequently involved in sitting down or getting up gait activity and maximum volumetric wear of 0.025 mm 3 for ladder up gait activity. The stair down activity showed the least linear and volumetric wear of 0.158 μm and 0.008 mm 3 , respectively, at the end of 10 million cycles. Graphical abstract Computational wear assessment of hip implants subjected to physically demanding tasks.

  6. Simulation of router action on a lathe to test the cutting tool performance in edge-trimming of graphite/epoxy composite

    NASA Astrophysics Data System (ADS)

    Ramulu, M.; Rogers, E.

    1994-04-01

    The predominant machining application with graphite/epoxy composite materials in aerospace industry is peripheral trimming. The computer numerically controlled (CNC) high speed routers required to do edge trimming work are generally scheduled for production work in industry and are not available for extensive cutter testing. Therefore, an experimental method of simulating the conditions of periphery trim using a lathe is developed in this paper. The validity of the test technique will be demonstrated by conducting carbide tool wear tests under dry cutting conditions. The experimental results will be analyzed to characterize the wear behavior of carbide cutting tools in machining the composite materials.

  7. Biotribology of Cartilage Wear in Knee and Hip Joints Review of Recent Developments

    NASA Astrophysics Data System (ADS)

    Gulsen, Akdogan; Merve, Goncu; Meltem, Parlak

    2018-01-01

    Nowadays, the problem of wear in the knee and hip joints is an important issue that concerns many people and still requires new solutions. In recent years, researchers dealing with knee and hip articular cartilage erosion continue to investigate the subject in terms of biotribology. In this study, recent developments and studies in this relevant area are been examined. By using the basic principles of tribology, useful new methods that can be used in the field of biotribology can be produced. Artificial joints designed using various materials such as metals, ceramics, polymers and composites are still being studied. New studies in this area will affect the development of implant technology. Different alloys or composites are currently being tested for new implant designs. Moving implants with a risk of wear are tested in laboratory conditions in simulator devices before they are used in the human body. Major topics such as nanotechnology, tissue engineering, orthopedics, tribology, biotribology, lubrication, organ transplantation and artificial organs, which are still important today, will be useful in the search for finding suitable solutions in the future in biotribological studies. This review article aims to provide an overview of in-vitro studies at the theoretical and laboratory conditions that must be performed prior to clinical investigation.

  8. Comparison of the wear and flexural characteristics of flowable resin composites for posterior lesions.

    PubMed

    Sumino, Natsu; Tsubota, Keishi; Takamizawa, Toshiki; Shiratsuchi, Koji; Miyazaki, Masashi; Latta, Mark A

    2013-01-01

    To determine the localized wear and flexural properties of flowable resin composites for posterior lesions compared with universal resin composites produced by the same manufacturers. Ten specimens of each of three flowable resins, G-ænial Universal Flo, G-ænial Flo and Clearfil Majesty Flow, and the corresponding resin composite materials, Kalore and Clearfil Majesty Esthetics, were prepared in custom fixtures and subjected to 400,000 wear machine cycles to simulate localized wear. The total maximum depth and volume loss of the wear facets was calculated for each specimen using a profilometer. A three-point bending test was performed to determine the flexural strength, modulus of elasticity and resilience. Values were statistically compared using one-way analysis of variance (ANOVA) followed by Tukey's Honestly Significant Difference (HSD) test. The wear depth ranged from 58.3-126.9 m and the volumetric loss ranged from 0.019-0.049 mm(3), with significant differences observed between restorative materials. The wear depth of G-ænial Universal Flo was significantly smaller than those of the other resin composites tested. The flexural strengths and elastic modulus ranged from 90.5-135.1 MPa and from 4.7-7.6 GPa, respectively. A significantly greater flexural strength and higher elastic modulus was found for G-ænial Universal Flo than the other composites. The wear and mechanical properties of the flowable resin composites tested suggested improved performance compared with universal resin composites.

  9. Thermo-Mechanical Effect on Poly Crystalline Boron Nitride Tool Life During Friction Stir Welding (Dwell Period)

    NASA Astrophysics Data System (ADS)

    Almoussawi, M.; Smith, A. J.

    2018-05-01

    Poly Crystalline Boron Nitride (PCBN) tool wear during the friction stir welding of high melting alloys is an obstacle to commercialize the process. This work simulates the friction stir welding process and tool wear during the plunge/dwell period of 14.8 mm EH46 thick plate steel. The Computational Fluid Dynamic (CFD) model was used for simulation and the wear of the tool is estimated from temperatures and shear stress profile on the tool surface. Two sets of tool rotational speeds were applied including 120 and 200 RPM. Seven plunge/dwell samples were prepared using PCBN FSW tool, six thermocouples were also embedded around each plunge/dwell case in order to record the temperatures during the welding process. Infinite focus microscopy technique was used to create macrographs for each case. The CFD result has been shown that a shear layer around the tool shoulder and probe-side denoted as thermo-mechanical affected zone (TMAZ) was formed and its size increase with tool rotational speed increase. Maximum peak temperature was also found to increase with tool rotational speed increase. PCBN tool wear under shoulder was found to increase with tool rotational speed increase as a result of tool's binder softening after reaching to a peak temperature exceeds 1250 °C. Tool wear also found to increase at probe-side bottom as a result of high shear stress associated with the decrease in the tool rotational speed. The amount of BN particles revealed by SEM in the TMAZ were compared with the CFD model.

  10. Metrology to quantify wear and creep of polyethylene tibial knee inserts.

    PubMed

    Muratoglu, Orhun K; Perinchief, Rebecca S; Bragdon, Charles R; O'Connor, Daniel O; Konrad, Reto; Harris, William H

    2003-05-01

    Assessment of damage on articular surfaces of ultrahigh molecular weight polyethylene tibial knee inserts primarily has been limited to qualitative methods, such as visual observation and classification of features such as pitting, delamination, and subsurface cracking. Semiquantitative methods also have been proposed to determine the linear penetration and volume of the scar that forms on articular surfaces of tibial knee inserts. The current authors report a new metrologic method that uses a coordinate measuring machine to quantify the dimensions of this scar. The articular surface of the insert is digitized with the coordinate measuring machine before and after regular intervals of testing on a knee simulator. The volume and linear penetration of the scar are calculated by mathematically taking the difference between the digitized surface maps of the worn and unworn articular surfaces. Three conventional polyethylene tibial knee inserts of a posterior cruciate-sparing design were subjected to five million cycles of normal gait on a displacement-driven knee wear simulator in bovine serum. A metrologic method was used to calculate creep and wear contributions to the scar formation on each tibial plateau. Weight loss of the inserts was determined gravimetrically with the appropriate correction for fluid absorption. The total average wear volume was 43 +/- 9 and 41 +/- 4 mm3 measured by the metrologic and gravimetric methods, respectively. The wear rate averaged 8.3 +/- 0.9 and 8.5 +/- 1.6 mm3 per million cycles measured by the metrologic and gravimetric methods, respectively. These comparisons reflected strong agreement between the metrologic and gravimetric methods.

  11. Are PEEK-on-Ceramic Bearings an Option for Total Disc Arthroplasty? An In Vitro Tribology Study.

    PubMed

    Siskey, Ryan; Ciccarelli, Lauren; Lui, Melissa K C; Kurtz, Steven M

    2016-11-01

    Most contemporary total disc replacements (TDRs) use conventional orthopaedic bearing couples such as ultrahigh-molecular-weight polyethylene (polyethylene) and cobalt-chromium (CoCr). Cervical total disc replacements incorporating polyetheretherketone (PEEK) bearings (specifically PEEK-on-PEEK bearings) have been previously investigated, but little is known about PEEK-on-ceramic bearings for TDR. (1) What is the tribologic behavior of a PEEK-on-ceramic bearing for cervical TDR under idealized, clean wear test conditions? (2) How does the PEEK-on-ceramic design perform under impingement conditions? (3) How is the PEEK-on-ceramic bearing affected by abrasive wear? (4) Is the particle morphology from PEEK-on-ceramic bearings for TDRs affected by adverse wear scenarios? PEEK-on-ceramic cervical TDR bearings were subjected to a 10 million cycle ideal wear test based on ASTM F2423 and ISO 181912-1 using a six-station spine wear simulator (MTS, Eden Prairie, MN, USA) with 5 g/L bovine serum concentration at 23° ± 2° C (ambient temperature). Validated 1 million cycle impingement and 5 million cycle abrasive tests were conducted on the PEEK-on-ceramic bearings based, in part, on retrieval analysis of a comparable bearing design as well as finite element analyses. The ceramic-on-PEEK couple was characterized for damage modes, mass and volume loss, and penetration and the lubricant was subjected to particle analysis. The resulting mass wear rate, volumetric wear rate, based on material density, and particle analysis were compared with clinically available cervical disc bearing couples. The three modes of wear (idealized, impingement, and abrasive) resulted in mean mass wear rates of 0.9 ± 0.2 mg/MC, 1.9 ± 0.5 mg/MC, and 2.8 ± 0.6 mg/MC, respectively. The mass wear rates were converted to volumetric wear rates using density and found to be 0.7 ± 0.1 mm 3 /MC, 1.5 ± 0.4 mm 3 /MC, and 2.1 ± 0.5 mm 3 /MC, respectively. During each test, the PEEK endplates were the primary sources of wear and demonstrated an abrasive wear mechanism. Under idealized and impingement conditions, the ceramic core also demonstrated slight polishing of the articulating surface but the change in mass was unmeasurable. During abrasive testing, the titanium transfer on the core was shown to polish over 5 MC of testing. In all cases and consistent with previous studies of other PEEK bearing couples, the particle size was primarily < 2 µm and morphology was smooth and spheroidal. Overall, the idealized PEEK-on-ceramic wear rate (0.7 ± 0.1 mm 3 /MC) appears comparable to the published wear rates for other polymer-on-hard bearing couples (0.3-6.7 mm 3 /MC) and within the range of 0.2 to 1.9 mm 3 /MC reported for PEEK-on-PEEK cervical disc designs. The particles, based on size and morphology, also suggest the wear mechanism is comparable between the PEEK-on-ceramic couple and other polymer-on-ceramic orthopaedic couples. The PEEK-on-ceramic bearing considered in this study is a novel bearing couple for use in total disc arthroplasty devices and will require clinical evaluation to fully assess the bearing couple and total disc design. However, the wear rates under idealized and adverse conditions, and particle size and morphology, suggest that PEEK-on-ceramic bearings may be a reasonable alternative to polyethylene-on-CoCr and metal-on-metal bearings currently used in cervical TDRs.

  12. A probabilistic-based approach to monitoring tool wear state and assessing its effect on workpiece quality in nickel-based alloys

    NASA Astrophysics Data System (ADS)

    Akhavan Niaki, Farbod

    The objective of this research is first to investigate the applicability and advantage of statistical state estimation methods for predicting tool wear in machining nickel-based superalloys over deterministic methods, and second to study the effects of cutting tool wear on the quality of the part. Nickel-based superalloys are among those classes of materials that are known as hard-to-machine alloys. These materials exhibit a unique combination of maintaining their strength at high temperature and have high resistance to corrosion and creep. These unique characteristics make them an ideal candidate for harsh environments like combustion chambers of gas turbines. However, the same characteristics that make nickel-based alloys suitable for aggressive conditions introduce difficulties when machining them. High strength and low thermal conductivity accelerate the cutting tool wear and increase the possibility of the in-process tool breakage. A blunt tool nominally deteriorates the surface integrity and damages quality of the machined part by inducing high tensile residual stresses, generating micro-cracks, altering the microstructure or leaving a poor roughness profile behind. As a consequence in this case, the expensive superalloy would have to be scrapped. The current dominant solution for industry is to sacrifice the productivity rate by replacing the tool in the early stages of its life or to choose conservative cutting conditions in order to lower the wear rate and preserve workpiece quality. Thus, monitoring the state of the cutting tool and estimating its effects on part quality is a critical task for increasing productivity and profitability in machining superalloys. This work aims to first introduce a probabilistic-based framework for estimating tool wear in milling and turning of superalloys and second to study the detrimental effects of functional state of the cutting tool in terms of wear and wear rate on part quality. In the milling operation, the mechanisms of tool failure were first identified and, based on the rapid catastrophic failure of the tool, a Bayesian inference method (i.e., Markov Chain Monte Carlo, MCMC) was used for parameter calibration of tool wear using a power mechanistic model. The calibrated model was then used in the state space probabilistic framework of a Kalman filter to estimate the tool flank wear. Furthermore, an on-machine laser measuring system was utilized and fused into the Kalman filter to improve the estimation accuracy. In the turning operation the behavior of progressive wear was investigated as well. Due to the nonlinear nature of wear in turning, an extended Kalman filter was designed for tracking progressive wear, and the results of the probabilistic-based method were compared with a deterministic technique, where significant improvement (more than 60% increase in estimation accuracy) was achieved. To fulfill the second objective of this research in understanding the underlying effects of wear on part quality in cutting nickel-based superalloys, a comprehensive study on surface roughness, dimensional integrity and residual stress was conducted. The estimated results derived from a probabilistic filter were used for finding the proper correlations between wear, surface roughness and dimensional integrity, along with a finite element simulation for predicting the residual stress profile for sharp and worn cutting tool conditions. The output of this research provides the essential information on condition monitoring of the tool and its effects on product quality. The low-cost Hall effect sensor used in this work to capture spindle power in the context of the stochastic filter can effectively estimate tool wear in both milling and turning operations, while the estimated wear can be used to generate knowledge of the state of workpiece surface integrity. Therefore the true functionality and efficiency of the tool in superalloy machining can be evaluated without additional high-cost sensing.

  13. The friction and wear of carbon-carbon composites for aircraft brakes

    NASA Astrophysics Data System (ADS)

    Hutton, Toby

    Many carbon-carbon composite aircraft brakes encounter high wear rates during low energy braking operations. The work presented in this thesis addresses this issue, but it also elucidates the microstructural changes and wear mechanisms that take place in these materials during all braking conditions encountered by aircraft brakes. A variety of investigations were conducted using friction and wear testing, as well as examination of wear surfaces and wear debris using OM, SEM, X-RD, TGA and Density Gradient Separation (DOS). Friction and wear tests were conducted on a PAN fibre/CVI matrix carbon-carbon composite (Dunlop) and a pitch fibre/Resin-CVI matrix carbon-carbon composite (Bendix). Extensive testing was undertaken on the Dunlop composites to asses the effects of composite architecture, fibre orientation and heat treatment temperatures on friction and wear. Other friction and wear tests, conducted on the base Dunlop composite, were used to investigate the relative influences of temperature and sliding speed. It was found that the effect of temperature was dominant over composite architecture, fibre orientation and sliding speed in governing the friction and wear performance of the Dunlop composites. The development of bulk temperatures in excess of 110 C by frictional heating resulted in smooth friction and a low wear rate. Reducing heat treatment temperature also reduced the thermal conductivity producing high interface temperatures, low smooth friction coefficients and low wear rates under low energy braking conditions. However, this was at the expense of high oxidative wear rates under higher energy braking conditions. The Bendix composites had lower thermal conductivities than the fully heat treated Dunlop composite and exhibited similar friction and wear behaviour to Dunlop composites heat treated to lower temperatures. Examination of the wear surfaces using OM and SEM revealed particulate or Type I surface debris on wear surfaces tested under low energy conditions. Type I debris was stable on the wear surfaces to a temperature of 110C, after which it was gradually converted to film material or Type II surface debris by the action of heat and shear. Type I debris was associated with high erratic friction coefficients (ja.=0.55- 0.65) and high wear rates (~ 8 mg/min), whereas. Type II debris was associated low smooth friction (|LI=0.35-0.45) and low wear rates (~ 4 mg/min). Analysis of the wear debris produced from testing on large dynamometers under the simulated conditions of taxiing and landing indicated that the structure of the wear debris became highly disordered as a result of the wear process. However, evidence from XRD, TGA and DGS suggested that, under very high energy conditions, such as those encountered in a rejected take off (RTO), the wear debris was partially regraphitised at the wear face by the action of heat and shear. The results from analysis of the wear surfaces and the wear debris supported the theory that a regenerative process or friction film formation, delamination and repair operated on the wear surfaces of these brake materials.

  14. STS-31 Pilot Bolden with beverages on the FB-SMS middeck during JSC training

    NASA Technical Reports Server (NTRS)

    1988-01-01

    STS-31 Pilot Charles F. Bolden holds three beverage containers while in front of the galley on the middeck of the fixed based (FB) shuttle mission simulator (SMS) during a training simulation at JSC's Mission Simulation and Training Facility Bldg 5. From the middeck, Bolden, wearing lightweight headset, simulates a communications link with ground controllers and fellow crewmembers.

  15. Carbon-based tribofilms from lubricating oils

    NASA Astrophysics Data System (ADS)

    Erdemir, Ali; Ramirez, Giovanni; Eryilmaz, Osman L.; Narayanan, Badri; Liao, Yifeng; Kamath, Ganesh; Sankaranarayanan, Subramanian K. R. S.

    2016-08-01

    Moving mechanical interfaces are commonly lubricated and separated by a combination of fluid films and solid ‘tribofilms’, which together ensure easy slippage and long wear life. The efficacy of the fluid film is governed by the viscosity of the base oil in the lubricant; the efficacy of the solid tribofilm, which is produced as a result of sliding contact between moving parts, relies upon the effectiveness of the lubricant’s anti-wear additive (typically zinc dialkyldithiophosphate). Minimizing friction and wear continues to be a challenge, and recent efforts have focused on enhancing the anti-friction and anti-wear properties of lubricants by incorporating inorganic nanoparticles and ionic liquids. Here, we describe the in operando formation of carbon-based tribofilms via dissociative extraction from base-oil molecules on catalytically active, sliding nanometre-scale crystalline surfaces, enabling base oils to provide not only the fluid but also the solid tribofilm. We study nanocrystalline catalytic coatings composed of nitrides of either molybdenum or vanadium, containing either copper or nickel catalysts, respectively. Structurally, the resulting tribofilms are similar to diamond-like carbon. Ball-on-disk tests at contact pressures of 1.3 gigapascals reveal that these tribofilms nearly eliminate wear, and provide lower friction than tribofilms formed with zinc dialkyldithiophosphate. Reactive and ab initio molecular-dynamics simulations show that the catalytic action of the coatings facilitates dehydrogenation of linear olefins in the lubricating oil and random scission of their carbon-carbon backbones; the products recombine to nucleate and grow a compact, amorphous lubricating tribofilm.

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Erdemir, Ali; Ramirez, Giovanni; Eryilmaz, Osman L.

    Moving mechanical interfaces are commonly lubricated and separated by a combination of fluid films and solid 'tribofilms', which together ensure easy slippage and long wear life(1). The efficacy of the fluid film is governed by the viscosity of the base oil in the lubricant; the efficacy of the solid tribofilm, which is produced as a result of sliding contact between moving parts, relies upon the effectiveness of the lubricant's anti-wear additive (typically zinc dialkyldithiophosphate)(2). Minimizing friction and wear continues to be a challenge, and recent efforts have focused on enhancing the anti-friction and anti-wear properties of lubricants by incorporating inorganicmore » nanoparticles and ionic liquids(3,4). Here, we describe the in operando formation of carbon-based tribofilms via dissociative extraction from base-oil molecules on catalytically active, sliding nanometre-scale crystalline surfaces, enabling base oils to provide not only the fluid but also the solid tribofilm. We study nanocrystalline catalytic coatings composed of nitrides of either molybdenum or vanadium, containing either copper or nickel catalysts, respectively. Structurally, the resulting tribofilms are similar to diamond-like carbon(5). Ball-on-disk tests at contact pressures of 1.3 gigapascals reveal that these tribofilms nearly eliminate wear, and provide lower friction than tribofilms formed with zinc dialkyldithiophosphate. Reactive and ab initio molecular-dynamics simulations show that the catalytic action of the coatings facilitates dehydrogenation of linear olefins in the lubricating oil and random scission of their carbon-carbon backbones; the products recombine to nucleate and grow a compact, amorphous lubricating tribofilm.« less

  17. Real-time and accurate rail wear measurement method and experimental analysis.

    PubMed

    Liu, Zhen; Li, Fengjiao; Huang, Bangkui; Zhang, Guangjun

    2014-08-01

    When a train is running on uneven or curved rails, it generates violent vibrations on the rails. As a result, the light plane of the single-line structured light vision sensor is not vertical, causing errors in rail wear measurements (referred to as vibration errors in this paper). To avoid vibration errors, a novel rail wear measurement method is introduced in this paper, which involves three main steps. First, a multi-line structured light vision sensor (which has at least two linear laser projectors) projects a stripe-shaped light onto the inside of the rail. Second, the central points of the light stripes in the image are extracted quickly, and the three-dimensional profile of the rail is obtained based on the mathematical model of the structured light vision sensor. Then, the obtained rail profile is transformed from the measurement coordinate frame (MCF) to the standard rail coordinate frame (RCF) by taking the three-dimensional profile of the measured rail waist as the datum. Finally, rail wear constraint points are adopted to simplify the location of the rail wear points, and the profile composed of the rail wear points are compared with the standard rail profile in RCF to determine the rail wear. Both real data experiments and simulation experiments show that the vibration errors can be eliminated when the proposed method is used.

  18. Comparison of the cytotoxicity of clinically relevant cobalt-chromium and alumina ceramic wear particles in vitro.

    PubMed

    Germain, M A; Hatton, A; Williams, S; Matthews, J B; Stone, M H; Fisher, J; Ingham, E

    2003-02-01

    Concern over polyethylene wear particle induced aseptic loosening of metal-on-polyethylene hip prostheses has led to renewed interest in alternative materials such as metal-on-metal and alumina ceramic-on-alumina ceramic for total hip replacement. This study compared the effects of clinically relevant cobalt-chromium and alumina ceramic wear particles on the viability of U937 histiocytes and L929 fibroblasts in vitro. Clinically relevant cobalt-chromium wear particles were generated using a flat pin-on-plate tribometer. The mean size of the clinically relevant metal particles was 29.5+/-6.3 nm (range 5-200 nm). Clinically relevant alumina ceramic particles were generated in the Leeds MkII anatomical hip simulator from a Mittelmieier prosthesis using micro-separation motion. This produced particles with a bimodal size distribution. The majority (98%) of the clinically relevant alumina ceramic wear debris was 5-20 nm in size. The cytotoxicity of the clinically relevant wear particles was compared to commercially available cobalt-chromium (9.87 microm+/-5.67) and alumina ceramic (0.503+/-0.19 microm) particles. The effects of the particles on the cells over a 5 day period at different particle volume (microm(3)) to cell number ratios were tested and viability determined using ATP-Lite(TM). Clinically relevant cobalt-chromium particles 50 and 5 microm(3) per cell reduced the viability of U937 cells by 97% and 42% and reduced the viability of L929 cells by 95% and 73%, respectively. At 50 microm(3) per cell, the clinically relevant ceramic particles reduced U937 cell viability by 18%. None of the other concentrations of the clinically relevant particles were toxic. The commercial cobalt-chromium and alumina particles did not affect the viability of either the U937 histiocytes or the L929 fibroblasts.Thus at equivalent particle volumes the clinically relevant cobalt-chromium particles were more toxic then the alumina ceramic particles. This study has emphasised the fact that the nature, size and volume of particles are important in assessing biological effects of wear debris on cells in vitro.

  19. Elucidation of atomic scale mechanisms for polytetrafluoroethylene tribology using molecular dynamics simulation

    NASA Astrophysics Data System (ADS)

    Barry, Peter R.

    Polytetrafluoroethylene (PTFE) is a polymer that has been widely exploited commercially as a result of its low friction, 'non-stick' properties. The polymer has found usage as 'non-stick,' chemically resistant coatings for bearings, valves, rollers and pipe linings with applications in industries ranging from food and chemical processing to construction, automotive and aerospace. The major drawback of PTFE in low friction applications involves its excessive wear rate. For decades, scientists and engineers have sought to improve the polymer's wear resistance while maintaining its low sliding friction by reinforcing the polymer matrix with a host of filler materials ranging from fibril to particulate. In this study, a different approach is taken in which the atomic scale phenomena between two crystalline PTFE surfaces in sliding contact are examined. The goal is to obtain atomic-level insights into PTFE's low friction and high wear rate to aid in the designing of effective polymer based tribological composites for extreme condition applications. To accomplish this, several tribological conditions were varied. These included sliding direction of the two polymer surfaces with respect to their chain alignment, sliding velocity, degree of crystalline phase rigidity, interfacial contact pressure, sample temperature and the presence of fluorocarbon fluids between the two crystalline PTFE surfaces. From these studies, it was found that crystalline PTFE-PTFE sliding demonstrates friction anisotropy. Low friction and molecular wear was observed when sliding in the direction of the chain alignment with high friction and wear behavior dominating when sliding in a direction perpendicular to the chain alignment. For the range of cross-link density (average linear density of 6.2 to 11.1 A) and sliding rate (5 m/s to 20 m/s) explored, a significant change in friction behavior or wear mechanisms was not observed. Under conditions of increased normal load or low temperature however, the frictional force increased linearly. Additionally, the inclusion of fluorocarbon molecular fluids at the sliding interface between the two crystalline PTFE surfaces resulted in a significant decrease in both the friction and wear of the surfaces.

  20. A study of the transient performance of annular hydrostatic journal bearings in liquid oxygen

    NASA Astrophysics Data System (ADS)

    Scharrer, J. K.; Tellier, J. G.; Hibbs, R. I.

    1992-07-01

    A test apparatus was used to simulate a cryogenic turbopump start transient in order to determine the liftoff and touchdown speed and amount of wear of an annular hydrostatic bearing in liquid oxygen. The bearing was made of sterling silver and the journal made of Inconel 718. The target application of this configuration is the pump end bearing of the Space Shuttle Main Engine High Pressure Liquid Oxygen Turbopump. Sixty-one transient cycles were performed in liquid oxygen with an additional three tests in liquid nitrogen to certify the test facility and configuration. The bearing showed no appreciable wear during the testing, and the results indicate that the performance of the bearing was not significantly degraded during the testing.

  1. STS-49 crew in JSC's FB Shuttle Mission Simulator (SMS) during simulation

    NASA Technical Reports Server (NTRS)

    1992-01-01

    STS-49 Endeavour, Orbiter Vehicle (OV) 105, crewmembers participate in a simulation in JSC's Fixed Base (FB) Shuttle Mission Simulator (SMS) located in the Mission Simulation and Training Facility Bldg 5. Wearing launch and entry suits (LESs) and launch and entry helmets (LEH) and seated on the FB-SMS middeck are (left to right) Mission Specialist (MS) Thomas D. Akers, MS Kathryn C. Thornton, and MS Pierre J. Thuot.

  2. Development of aircraft brake materials. [evaluation of metal and ceramic materials in sliding tests simulation of aircraft braking

    NASA Technical Reports Server (NTRS)

    Ho, T. L.; Peterson, M. B.

    1974-01-01

    The requirements of brake materials were outlined and a survey made to select materials to meet the needs of high temperature brakes. A number of metals and ceramic materials were selected and evaluated in sliding tests which simulated aircraft braking. Nickel, molybdenum tungsten, Zr02, high temperature cements and carbons were tested. Additives were then incorporated into these materials to optimize their wear or strength behavior with particular emphasis on nickel and molybdenum base materials and a high temperature potassium silicate cement. Optimum materials were developed which improved wear behavior over conventional brake materials in the simulated test. The best materials are a nickel, aluminum oxide, lead tungstate composition containing graphite or molybdenum disulphite; a molybdenum base material containing LPA100 (an intermetallic compound of cobalt, molybdenum, and silicon); and a carbon material (P5).

  3. STS-47 Commander Gibson and MS Apt in JSC WETF for bailout exercises

    NASA Technical Reports Server (NTRS)

    1992-01-01

    STS-47 Endeavour, Orbiter Vehicle (OV) 105, Commander Robert L. Gibson, wearing launch and entry suit (LES) and launch and entry helmet (LEH), listens to instructions before participating in launch emergency egress (bailout) exercises in JSC's Weightless Environment Trainining Facility (WETF) Bldg 29. Mission Specialist (MS) Jerome Apt, wearing LES and LES parachute, is seen in the background. This exercise is conducted in the WETF pool to simulate a water landing.

  4. A rolling-sliding bench test for investigating rear axle lubrication

    DOE PAGES

    Stump, Benjamin C.; Zhou, Yan; Viola, Michael B.; ...

    2018-02-07

    An automotive rear axle is composed of a set of hypoid gears, whose contact surfaces experience a complex combination of rolling contact fatigue damage and sliding wear. Full-scale rear axle dynamometer tests are used in the industry for efficiency and durability assessment. Here, this study developed a bench-scale rolling-sliding test protocol by simulating the contact pressure, oil temperature, and lubrication regime experienced in a dynamometer duty cycle test. Initial bench results have demonstrated the ability of generating both rolling contact-induced micropitting and sliding wear and the feasibility of investigating the impact of slide-to-roll ratio, surface roughness, test duration, and oilmore » temperature on the friction behavior, vibration noise, and surface damage. Finally, this bench test will allow studying candidate rear axle lubricants and materials under relevant conditions.« less

  5. Numerical analysis and experimental studies on solenoid common rail diesel injector with worn control valve

    NASA Astrophysics Data System (ADS)

    Krivtsov, S. N.; Yakimov, I. V.; Ozornin, S. P.

    2018-03-01

    A mathematical model of a solenoid common rail fuel injector was developed. Its difference from existing models is control valve wear simulation. A common rail injector of 0445110376 Series (Cummins ISf 2.8 Diesel engine) produced by Bosch Company was used as a research object. Injector parameters (fuel delivery and back leakage) were determined by calculation and experimental methods. GT-Suite model average R2 is 0.93 which means that it predicts the injection rate shape very accurately (nominal and marginal technical conditions of an injector). Numerical analysis and experimental studies showed that control valve wear increases back leakage and fuel delivery (especially at 160 MPa). The regression models for determining fuel delivery and back leakage effects on fuel pressure and energizing time were developed (for nominal and marginal technical conditions).

  6. A rolling-sliding bench test for investigating rear axle lubrication

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stump, Benjamin C.; Zhou, Yan; Viola, Michael B.

    An automotive rear axle is composed of a set of hypoid gears, whose contact surfaces experience a complex combination of rolling contact fatigue damage and sliding wear. Full-scale rear axle dynamometer tests are used in the industry for efficiency and durability assessment. Here, this study developed a bench-scale rolling-sliding test protocol by simulating the contact pressure, oil temperature, and lubrication regime experienced in a dynamometer duty cycle test. Initial bench results have demonstrated the ability of generating both rolling contact-induced micropitting and sliding wear and the feasibility of investigating the impact of slide-to-roll ratio, surface roughness, test duration, and oilmore » temperature on the friction behavior, vibration noise, and surface damage. Finally, this bench test will allow studying candidate rear axle lubricants and materials under relevant conditions.« less

  7. Effect of Laser Remelting on Friction-Wear Behaviors of Cold Sprayed Al Coatings in 3.5% NaCl Solution

    PubMed Central

    Jing, Zhang; Dejun, Kong

    2018-01-01

    A cold sprayed Al coating on S355 structural steel was processed using a laser remelting (LR). The surface and cross-section morphologies, chemical compositions, and phases of as-obtained Al coating before and after LR were analyzed using a scanning electronic microscope (SEM), energy dispersive spectrometer (EDS), and X-ray diffractometer (XRD), respectively, and their hardness was measured using a micro-hardness tester. The friction-wear behaviors of Al coating before and after LR in 3.5% NaCl solution were conducted to simulate the sand and gravel scouring on its surface in seawater, the effects of wear loads and speeds on the tribological properties of Al coating were analyzed, and the wear mechanisms under different wear loads and speeds were also discussed. The results show that the Al coating after LR is primarily composed of an Al phase and its hardness is 104.66 HV, increasing 54.70 HV than the cold sprayed Al coating. The average coefficient of friction (COF) of cold sprayed Al coating at the wear load of 0.5, 1.0 and 1.5 N is 0.285, 0.239, and 0.435, respectively, while that after LR is 0.243, 0.227, and 0.327, respectively, decreased by 14.73%, 5.02% and 24.83% compared to the cold sprayed Al coating. The wear rate of cold sprayed Al coating at the wear load of 0.5, 1.0 and 1.5 N is 1.60 × 10−4, 2.36 × 10−4, and 2.40 × 10−4 mm3/m·N, respectively, while that after LR is 1.59 × 10−4, 1.70 × 10−4, and 1.94 × 10–4 mm3/m·N, respectively, decreased by 1%, 32%, and 23%, respectively, indicating that LR has high anti-friction performance. Under the wear load action of 1.0 N, the average COF of laser remelted Al coating at the wear speeds of 300, 400 and 500 times/min is 0.294, 0.279, and 0.239, respectively, and the corresponding wear rate is 1.06 × 10−4, 1.24 × 10−4, and 1.70 × 10−4 mm3/m·N, respectively. The wear mechanism of cold sprayed Al coating is primarily corrosion wear at the loads of 0.5 and 1.0 N, and that at the load of 1.5 N is abrasive wear and fatigue wear; while that after LR is abrasive wear and fatigue wear, with no corrosion wear, showing that LR improves its corrosion and wear resistance. PMID:29439485

  8. Effect of Laser Remelting on Friction-Wear Behaviors of Cold Sprayed Al Coatings in 3.5% NaCl Solution.

    PubMed

    Jing, Zhang; Dejun, Kong

    2018-02-11

    A cold sprayed Al coating on S355 structural steel was processed using a laser remelting (LR). The surface and cross-section morphologies, chemical compositions, and phases of as-obtained Al coating before and after LR were analyzed using a scanning electronic microscope (SEM), energy dispersive spectrometer (EDS), and X-ray diffractometer (XRD), respectively, and their hardness was measured using a micro-hardness tester. The friction-wear behaviors of Al coating before and after LR in 3.5% NaCl solution were conducted to simulate the sand and gravel scouring on its surface in seawater, the effects of wear loads and speeds on the tribological properties of Al coating were analyzed, and the wear mechanisms under different wear loads and speeds were also discussed. The results show that the Al coating after LR is primarily composed of an Al phase and its hardness is 104.66 HV, increasing 54.70 HV than the cold sprayed Al coating. The average coefficient of friction (COF) of cold sprayed Al coating at the wear load of 0.5, 1.0 and 1.5 N is 0.285, 0.239, and 0.435, respectively, while that after LR is 0.243, 0.227, and 0.327, respectively, decreased by 14.73%, 5.02% and 24.83% compared to the cold sprayed Al coating. The wear rate of cold sprayed Al coating at the wear load of 0.5, 1.0 and 1.5 N is 1.60 × 10 -4 , 2.36 × 10 -4 , and 2.40 × 10 -4 mm³/m·N, respectively, while that after LR is 1.59 × 10 -4 , 1.70 × 10 -4 , and 1.94 × 10 -4 mm³/m·N, respectively, decreased by 1%, 32%, and 23%, respectively, indicating that LR has high anti-friction performance. Under the wear load action of 1.0 N, the average COF of laser remelted Al coating at the wear speeds of 300, 400 and 500 times/min is 0.294, 0.279, and 0.239, respectively, and the corresponding wear rate is 1.06 × 10 -4 , 1.24 × 10 -4 , and 1.70 × 10 -4 mm³/m·N, respectively. The wear mechanism of cold sprayed Al coating is primarily corrosion wear at the loads of 0.5 and 1.0 N, and that at the load of 1.5 N is abrasive wear and fatigue wear; while that after LR is abrasive wear and fatigue wear, with no corrosion wear, showing that LR improves its corrosion and wear resistance.

  9. Characterization and tribology of PEG-like coatings on UHMWPE for total hip replacements.

    PubMed

    Kane, Sheryl R; Ashby, Paul D; Pruitt, Lisa A

    2010-03-15

    A crosslinked hydrogel coating similar to poly(ethylene glycol) (PEG) was covalently bonded to the surface of ultrahigh molecular weight polyethylene (UHMWPE) to improve the lubricity and wear resistance of the UHWMPE for use in total joint replacements. The chemistry, hydrophilicity, and protein adsorption resistance of the coatings were determined, and the wear behavior of the PEG-like coating was examined by two methods: pin-on-disk tribometry to evaluate macroscale behavior, and atomic force microscopy (AFM) to simulate asperity wear. As expected, the coating was found to be highly PEG-like, with approximately 83% ether content by x-ray photoelectron spectroscopy and more hydrophilic and resistant to protein adsorption than uncoated UHMWPE. Pin-on-disk testing showed that the PEG-like coating could survive 3 MPa of contact pressure, comparable to that experienced by total hip replacements. AFM nanoscratching experiments uncovered three damage mechanisms for the coatings: adhesion/microfracture, pure adhesion, and delamination. The latter two mechanisms appear to correlate well with wear patterns induced by pin-on-disk testing and evaluated by attenuated total reflection Fourier transform infrared spectroscopy mapping. Understanding the mechanisms by which the PEG-like coatings wear is critical for improving the behavior of subsequent generations of wear-resistant hydrogel coatings. (c) 2009 Wiley Periodicals, Inc.

  10. The effect of firefighter protective garments, self-contained breathing apparatus and exertion in the heat on postural sway.

    PubMed

    White, Scott C; Hostler, David

    2017-08-01

    Fire suppression wearing thermal protective clothing (TPC) and self-contained breathing apparatus (SCBA) challenges a firefighter's balance and may explain firefighter falls. Postural control based on force plate centre of pressure (COP) was compared for healthy subjects wearing TPC and SCBA before and after 20 min of heavy physical exertion in hot conditions. Baseline measures with and without TPC and SCBA (two different SCBA cylinder masses) were compared before and after exertion that included elements of fire suppression activities in an environmental chamber. COP excursion and variability increased with exertion for TPC and SCBA conditions compared to non-stressed conditions. The two different cylinder masses had no significant effect. Wearing TPC and SCBA when physically stressed in a hot environment increases postural sway and exacerbates postural control. Subjects compensated for the extra mass and adjusted to control postural sway with the addition of TPC and SCBA, but the stress protocol amplified these adjustments. Practitioner Summary: Firefighters wear thermal protective clothing (TPC) and self-contained breathing apparatus (SCBA) when heat-stressed and fatigued. Wearing TPC and SCBA was found to negatively impact balance when stressed, but not for non-stressed or two different sized SCBA tanks. Simulating fire-ground conditions wearing TPC and SCBA should be considered for improving balance.

  11. Visual attention on a respiratory function monitor during simulated neonatal resuscitation: an eye-tracking study.

    PubMed

    Katz, Trixie A; Weinberg, Danielle D; Fishman, Claire E; Nadkarni, Vinay; Tremoulet, Patrice; Te Pas, Arjan B; Sarcevic, Aleksandra; Foglia, Elizabeth E

    2018-06-14

    A respiratory function monitor (RFM) may improve positive pressure ventilation (PPV) technique, but many providers do not use RFM data appropriately during delivery room resuscitation. We sought to use eye-tracking technology to identify RFM parameters that neonatal providers view most commonly during simulated PPV. Mixed methods study. Neonatal providers performed RFM-guided PPV on a neonatal manikin while wearing eye-tracking glasses to quantify visual attention on displayed RFM parameters (ie, exhaled tidal volume, flow, leak). Participants subsequently provided qualitative feedback on the eye-tracking glasses. Level 3 academic neonatal intensive care unit. Twenty neonatal resuscitation providers. Visual attention: overall gaze sample percentage; total gaze duration, visit count and average visit duration for each displayed RFM parameter. Qualitative feedback: willingness to wear eye-tracking glasses during clinical resuscitation. Twenty providers participated in this study. The mean gaze sample captured wa s 93% (SD 4%). Exhaled tidal volume waveform was the RFM parameter with the highest total gaze duration (median 23%, IQR 13-51%), highest visit count (median 5.17 per 10 s, IQR 2.82-6.16) and longest visit duration (median 0.48 s, IQR 0.38-0.81 s). All participants were willing to wear the glasses during clinical resuscitation. Wearable eye-tracking technology is feasible to identify gaze fixation on the RFM display and is well accepted by providers. Neonatal providers look at exhaled tidal volume more than any other RFM parameter. Future applications of eye-tracking technology include use during clinical resuscitation. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  12. Rolling Contact Fatigue and Wear Behavior of High-Performance Railway Wheel Steels Under Various Rolling-Sliding Contact Conditions

    NASA Astrophysics Data System (ADS)

    Faccoli, Michela; Petrogalli, Candida; Lancini, Matteo; Ghidini, Andrea; Mazzù, Angelo

    2017-07-01

    An experimental investigation was carried out to study and compare the response to cyclic loading of the high-performance railway wheel steels ER8 EN13262 and SUPERLOS®. Rolling contact tests were performed with the same contact pressure, rolling speed and sliding/rolling ratio, varying the lubrication regime to simulate different climatic conditions. The samples, machined out of wheel rims at two depths within the reprofiling layer, were coupled with UIC 900A rail steel samples. The wear rates, friction coefficients and hardness were correlated with the deformation beneath the contact surface. The crack morphology was studied, and the damage mechanisms were identified. The distribution of crack length and depth at the end of the dry tests was analyzed to quantify the damage. The main difference between the steels lies in the response of the external samples to dry contact: SUPERLOS® is subjected to a higher wear and lower friction coefficient than ER8, and this reduces the density of surface cracks that can propagate under wet contact conditions. The analysis of feedback data from in-service wheels confirmed the experimental results.

  13. STS-26 MS Lounge in fixed based (FB) shuttle mission simulator (SMS)

    NASA Technical Reports Server (NTRS)

    1988-01-01

    STS-26 Discovery, Orbiter Vehicle (OV) 103, Mission Specialist (MS) John M. Lounge, wearing comunications kit assembly headset and crouched on the aft flight deck, performs checklist inspection during training session. The STS-26 crew is training in the fixed base (FB) shuttle mission simulator (SMS) located in JSC Mission Simulation and Training Facility Bldg 5.

  14. Shielding Effect of Lead Glasses on Radiologists' Eye Lens Exposure in Interventional Procedures.

    PubMed

    Hu, Panpan; Kong, Yan; Chen, Bo; Liu, Qianqian; Zhuo, Weihai; Liu, Haikuan

    2017-04-20

    To study the shielding effect of radiologists' eye lens with lead glasses of different equivalent thicknesses and sizes in interventional radiology procedures. Using the human voxel phantom with a more accurate model of the eye and MCNPX software, eye lens doses of the radiologists who wearing different kinds of lead glasses were simulated, different beam projections were taken into consideration during the simulation. Measurements were also performed with the physical model to verify simulation results. Simulation results showed that the eye lens doses were reduced by a factor from 3 to 9 when wearing a 20 cm2-sized lead glasses with the equivalent thickness ranging from 0.1 to 1.0 mm Pb. The increase of dose reduction factor (DRF) was not significant whenever increase the lead equivalent of glasses of which larger than 0.35 mm. Furthermore, the DRF was proportional to the size of glass lens from 6 to 30 cm2 with the same lead equivalent. The simulation results were in well agreements with the measured ones. For more reasonable and effective protection of the eye lens of interventional radiologists, a pair of glasses with a lead equivalent of 0.5 mm Pb and large-sized (at least 27 cm2 per glass) lens are recommended. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  15. Experimental Measurement of the Static Coefficient of Friction at the Ti-Ti Taper Connection in Total Hip Arthroplasty.

    PubMed

    Bitter, T; Khan, I; Marriott, T; Schreurs, B W; Verdonschot, N; Janssen, D

    2016-03-01

    The modular taper junction in total hip replacements has been implicated as a possible source of wear. The finite-element (FE) method can be used to study the wear potential at the taper junction. For such simulations it is important to implement representative contact parameters, in order to achieve accurate results. One of the main parameters in FE simulations is the coefficient of friction. However, in current literature, there is quite a wide spread in coefficient of friction values (0.15 - 0.8), which has a significant effect on the outcome of the FE simulations. Therefore, to obtain more accurate results, one should use a coefficient of friction that is determined for the specific material couple being analyzed. In this study, the static coefficient of friction was determined for two types of titanium-on-titanium stem-adaptor couples, using actual cut-outs of the final implants, to ensure that the coefficient of friction was determined consistently for the actual implant material and surface finish characteristics. Two types of tapers were examined, Biomet type-1 and 12/14, where type-1 has a polished surface finish and the 12/14 is a microgrooved system. We found static coefficients of friction of 0.19 and 0.29 for the 12/14 and type-1 stem-adaptor couples, respectively.

  16. Wear Mechanism Maps for Magnesium Alloy AM60 and Composite AM60-9% (Al2O3)f

    NASA Astrophysics Data System (ADS)

    Ullah Khan, Muhammad Zafar

    The purpose of this work was to study the tribological behaviour of squeeze cast Mg alloy AM60 and its composite AM60-9% (Al2O3) f. Dry sliding wear tests were performed on specimens of these materials using a block-on-ring tribometer which was equipped with a COF and temperature measurement system. Wear, COF and temperature maps were constructed to illustrate the effect of temperature and COF on the wear behaviour of the Mg alloy and it's composite. Four wear regimes namely low, mild, transient and severe wear were identified. The transition from mild to severe wear regime was found to be dependent on the bulk temperature of the specimen. Oxidational wear prevailed in low and mild wear whereas plastic deformation induced wear and melt wear controlled the wear rates in transient and severe wear regimes, respectively. This study shows that the incorporation of Al2O3 fibres in AM60 alloy improved the wear resistance of the resulting composite by delaying the transition from mild to severe wear.

  17. The Effects of Fatal Vision Goggles on Drinking and Driving Intentions in College Students

    ERIC Educational Resources Information Center

    Hennessy, Dwight A.; Lanni-Manley, Elizabeth; Maiorana, Nicole

    2006-01-01

    The present study was designed to examine the effectiveness of Fatal Vision Goggles in reducing intentions to drink and drive. Participants performed a field sobriety task and drove in a traffic simulator while wearing the goggles. A regression analysis was performed in order to predict changes in intentions to drink and drive, using typical…

  18. Astronaut Sam Gemar, wearing EMU, prepares for training in WETF

    NASA Image and Video Library

    1987-03-01

    S87-26630 (March 1987) --- Astronaut Charles D. (Sam) Gemar, wearing a training version of the Extravehicular Mobility Unit (EMU) space suit, prepares to be emersed in the 25-ft. deep waters of the Weightless Environment Training Facility (WET-F) at the Johnson Space Center (JSC). Once underwater, Gemar was able to achieve a neutrally buoyant state and to simulate the floating type activities of an astronaut in microgravity. Gemar began training as an astronaut candidate in the summer of 1985.

  19. Fabrication and wear test of a continuous fiber/particulate composite total surface hip replacement

    NASA Technical Reports Server (NTRS)

    Roberts, J. C.; Ling, F. F.; Jones, W. R., Jr.

    1981-01-01

    Continuous fiber woven E-glass composite femoral shells having the ame elastic properties as bone were fabricated. The shells were then encrusted with filled epoxy wear resistant coatings and run dry against ultrahigh molecular weight polyethylene acetabular cups in 42,000 and 250,000 cycle were tests on a total hip simulator. The tribological characteristics of these shells atriculating with the acetabular cups are comparable to a vitallium bal articulating with an ultrahigh molecular weight polyethylene cup.

  20. STS-32 MS Dunbar wearing LES prepares for WETF water egress training

    NASA Technical Reports Server (NTRS)

    1989-01-01

    STS-32 Mission Specialist (MS) Bonnie J. Dunbar, wearing a launch and entry suit (LES), orange parachute harness and life vest, is briefed on emergency egress procedures in JSC's Weightless Environment Training Facility (WETF) Bldg 29. During the exercises the crew practiced the procedures to follow in the event of an emergency aboard the Space Shuttle and familiarized themselves with post-Challenger pole system of emergency egress. The crewmembers will simulate parachuting into water by using the WETF's nearby 25 ft deep pool.

  1. Effects of EVA gloves on grip strength and fatigue under low temperature and low pressure.

    PubMed

    Tian, Yinsheng; Ding, Li; Liu, Heqing; Li, Yan; Li, Deyu; Wang, Li

    2016-03-01

    To study the effects of wearing extravehicular activity (EVA) gloves on grip strength and fatigue in low temperature, low pressure and mixing of two factors (low temperature and low pressure). The maximum grip strength and fatigue tests were performed with 10 healthy male subjects wearing gloves in a variety of simulated environments. The data was analysed using the normalization method. The results showed that wearing gloves significantly affected the maximum grip strength and fatigue. Pressure (29.6, 39.2 kPa) had more influence on the maximum grip compared with control group while low temperatures (-50, -90, -110 °C) had no influence on grip but affected fatigue dramatically. The results also showed that the maximum grip strength and fatigue were influenced significantly in a compound environment. Space environment remarkably reduced strength and endurance of the astronauts. However, the effects brought by the compound environment cannot be understood as the superimposition of low temperature and pressure effects. Copyright © 2015 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  2. Experimental study of modification mechanism at a wear-resistant surfacing

    NASA Astrophysics Data System (ADS)

    Dema, R. R.; Amirov, R. N.; Kalugina, O. B.

    2018-01-01

    In the study, a simulation of the crystallization process was carried out for the deposition of the near-eutectic structure alloys with inoculants presence in order to reveal the regularities of the inoculant effect and parameters of the process mode simulating surfacing on the structure of the crystallization front and on the nucleation rate and kinetics of growth of equiaxed crystallites of primary phases occurring in the volume of the melt. The simulation technique of primary crystallization of alloys similar to eutectic alloys in the presence of modifiers is offered. The possibility of fully eutectic structure during surfacing of nominal hypereutectic alloys of type white cast irons in wide range of deviations from the nominal composition is revealed.

  3. Optical coherence tomography applied to the evaluation of wear of composite resin for posterior teeth

    NASA Astrophysics Data System (ADS)

    Mota, Cláudia C. B. O.; Guerra, Bruna A.; Machado, Brena S. A.; Cabral, Adolfo J.; Gomes, Anderson S. L.

    2015-06-01

    Resin composites are widely used as restorative materials due to their excellent aesthetical and mechanical properties. Posterior teeth are constantly submitted to occlusal stress and upon restoration require more resistant resins. The aim of this study was to analyze in vitro the wear suffered over time by restorations in resin composite in posterior teeth, by Optical Coherence Tomography (OCT). 30 molars had occlusal cavities prepared and were randomly divided into three groups (n=10) and restored with resin composite: G1: Filtek P90 (3M/ESPE), G2: Tetric N-Ceram (Ivoclar Vivadent); G3: Filtek P60 (3M/ESPE). Specimens were subjected to initial analysis by OCT (OCP930SR, Thorlabs, axial resolution 6.2 μm) and stereoscopic microscope. Specimens were submitted to thermocycling (500 cycles, 5-55 °C) and subjected to simulated wear through a machine chewing movements (Wear Machine WM001), projecting four years of use. After mechanical cycles, the specimens were submitted to a second evaluation by the OCT and stereoscopic microscopy. As a result, it was observed that 90% of the restorations of both groups had fractures and/or points of stress concentration, considered niches for early dissemination of new fracture lines. It was also found that G1 and G2 had more points of stress concentration, whereas G3 had a higher incidence of fracture lines already propagated. It was concluded that the G3 showed more brittle behavior at the masticatory wear when compared to G1 and G2.

  4. Advanced ceramic material for high temperature turbine tip seals

    NASA Technical Reports Server (NTRS)

    Solomon, N. G.; Vogan, J. W.

    1978-01-01

    Ceramic material systems are being considered for potential use as turbine blade tip gas path seals at temperatures up to 1370 1/4 C. Silicon carbide and silicon nitride structures were selected for study since an initial analysis of the problem gave these materials the greatest potential for development into a successful materials system. Segments of silicon nitride and silicon carbide materials over a range of densities, processed by various methods, a honeycomb structure of silicon nitride and ceramic blade tip inserts fabricated from both materials by hot pressing were tested singly and in combination. The evaluations included wear under simulated engine blade tip rub conditions, thermal stability, impact resistance, machinability, hot gas erosion and feasibility of fabrication into engine components. The silicon nitride honeycomb and low-density silicon carbide using a selected grain size distribution gave the most promising results as rub-tolerant shroud liners. Ceramic blade tip inserts made from hot-pressed silicon nitride gave excellent test results. Their behavior closely simulated metal tips. Wear was similar to that of metals but reduced by a factor of six.

  5. Simulation in Training Workshop 2012

    DTIC Science & Technology

    2013-06-01

    17. Hanson, J ., Wearing, A., Smith, G, Nguyen, T ., Goodburn, D., & Davis, S. (2012). Military Meta-Cognitive Profiles (MMCPs) and more effective...the Mawson Centre in Adelaide, South Australia. UNCLASSIFIED DSTO-GD-0754 UNCLASSIFIED 2 2.1 Opening Remarks The workshop commenced with the...Reviews of simulation-based training and education 1. Belanich, J ., Mullin, L.N., & Dressel, J.D. (2004). Symposium on PC-based Simulations and

  6. Dr. von Braun Tries Out the Neutral Buoyancy Simulator (NBS)

    NASA Technical Reports Server (NTRS)

    1967-01-01

    Astronaut L. Gordon Cooper checks the neck ring of a space suit worn by Marshall Space Flight Center (MSFC) Director, Dr. von Braun before he submerges into the water of the MSFC Neutral Buoyancy Simulator (NBS). Wearing a pressurized suit and weighted to a neutrally buoyant condition, Dr. von Braun was able to perform tasks underwater which simulated weightless conditions found in space.

  7. STS-41 MS Akers assisted by technician on SMS middeck at JSC

    NASA Technical Reports Server (NTRS)

    1990-01-01

    STS-41 Mission Specialist (MS) Thomas D. Akers, wearing launch and entry suit (LES) and launch and entry helmet (LEH), is assisted by a technician on the middeck of JSC's Shuttle Mission Simulator (SMS). Akers seated in the mission specialists chairis participating in a simulation of mission events. The SMS is located in JSC's Mission Simulation and Training Facility Bldg 5.

  8. Linking Microstructural Evolution and Tribology in Metallic Contacts

    NASA Astrophysics Data System (ADS)

    Chandross, Michael; Cheng, Shengfeng; Argibay, Nicolas

    Tribologists rely on phenomenological models to describe the seemingly disjointed steady-state regimes of metal wear. Pure metals such as gold - frequently used in electrical contacts - exhibit high friction and wear. In contrast, nanocrystalline metals often show much lower friction and wear. The engineering community has generally used a phenomenological connection between hardness and friction/wear to explain this macroscale response and guide designs. We present results of recent simulations and experiments that demonstrate a general framework for connecting materials properties (i.e. microstructural evolution) to tribological response. We present evidence that competition between grain refinement (from cold working), grain coarsening (from stress-induced grain growth), and wear (delamination and plowing) can be used to describe transient and steady state tribological behavior of metals, alloys and composites. We explore the seemingly disjointed steady-state friction regimes of metals and alloys, with a goal of elucidating the structure-property relationships, allowing for the engineering of tribological materials and contacts based on the kinetics of grain boundary motion. Sandia National Laboratories is a multi-program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000.

  9. Quantification of the Effect of Cross-shear on the Wear of Conventional and Highly Cross-linked UHMWPE

    PubMed Central

    Kang, Lu; Galvin, Alison L.; Brown, Thomas D.; Jin, Zhongmin; Fisher, John

    2008-01-01

    A computational model has been developed to quantify the degree of cross-shear of a polyethylene pin articulating against a metallic plate, based on the direct simulation of a multidirectional pin-on-plate wear machine. The principal molecular orientation (PMO) was determined for each polymer site. The frictional work in the direction perpendicular to the PMO was assumed to produce the greatest orientation softening (Wang et al., 1997). The cross-shear ratio (CS) was defined as the frictional work perpendicular to the PMO direction, divided by the total frictional work. Cross-shear on the pin contact surface was location-specific, and of continuously changing magnitude because the direction of frictional force continuously changed due to pin rotation. The polymer pin motion was varied from a purely linear track (CS=0) up to a maximum rotation of ±55° (CS=0.254). The relationship between wear factors (K) measured experimentally and theoretically predicted CS was defined using logarithmic functions for both conventional and highly cross-linked UHMWPE. Cross-shear increased the apparent wear factor for both polyethylenes by more than 5-fold compared to unidirectional wear. PMID:17936763

  10. Wear-Out Sensitivity Analysis Project Abstract

    NASA Technical Reports Server (NTRS)

    Harris, Adam

    2015-01-01

    During the course of the Summer 2015 internship session, I worked in the Reliability and Maintainability group of the ISS Safety and Mission Assurance department. My project was a statistical analysis of how sensitive ORU's (Orbital Replacement Units) are to a reliability parameter called the wear-out characteristic. The intended goal of this was to determine a worst case scenario of how many spares would be needed if multiple systems started exhibiting wear-out characteristics simultaneously. The goal was also to determine which parts would be most likely to do so. In order to do this, my duties were to take historical data of operational times and failure times of these ORU's and use them to build predictive models of failure using probability distribution functions, mainly the Weibull distribution. Then, I ran Monte Carlo Simulations to see how an entire population of these components would perform. From here, my final duty was to vary the wear-out characteristic from the intrinsic value, to extremely high wear-out values and determine how much the probability of sufficiency of the population would shift. This was done for around 30 different ORU populations on board the ISS.

  11. Mechanical properties of nitrogen-rich surface layers on SS304 treated by plasma immersion ion implantation

    NASA Astrophysics Data System (ADS)

    Fernandes, B. B.; Mändl, S.; Oliveira, R. M.; Ueda, M.

    2014-08-01

    The formation of hard and wear resistant surface regions for austenitic stainless steel through different nitriding and nitrogen implantation processes at intermediate temperatures is an established technology. As the inserted nitrogen remains in solid solution, an expanded austenite phase is formed, accounting for these surface improvements. However, experiments on long-term behavior and exact wear processes within the expanded austenite layer are still missing. Here, the modified layers were produced using plasma immersion ion implantation with nitrogen gas and had a thickness of up to 4 μm, depending on the processing temperature. Thicker layers or those with higher surface nitrogen contents presented better wear resistance, according to detailed microscopic investigation on abrasion, plastic deformation, cracking and redeposition of material inside the wear tracks. At the same time, cyclic fatigue testing employing a nanoindenter equipped with a diamond ball was carried out at different absolute loads and relative unloadings. As the stress distribution between the modified layer and the substrate changes with increasing load, additional simulations were performed for obtaining these complex stress distributions. While high nitrogen concentration and/or thicker layers improve the wear resistance and hardness, these modifications simultaneously reduce the surface fatigue resistance.

  12. Surface property modification of silicon

    NASA Technical Reports Server (NTRS)

    Danyluk, S.

    1984-01-01

    The main emphasis of this work has been to determine the wear rate of silicon in fluid environments and the parameters that influence wear. Three tests were carried out on single crystal Czochralski silicon wafers: circular and linear multiple-scratch tests in fluids by a pyramidal diamond simulated fixed-particle abrasion; microhardness and three-point bend tests were used to determine the hardness and fracture toughness of abraded silicon and the extent of damage induced by abrasion. The wear rate of (100) and (111) n and p-type single crystal Cz silicon abraded by a pyramidal diamond in ethanol, methanol, acetone and de-ionized water was determined by measuring the cross-sectional areas of grooves of the circular and linear multiple-scratch tests. The wear rate depends on the loads on the diamond and is highest for ethanol and lowest for de-ionized water. The surface morphology of the grooves showed lateral and median cracks as well as a plastically deformed region. The hardness and fracture toughness are critical parameters that influence the wear rate. Microhardness tests were conducted to determine the hardness as influenced by fluids. Median cracks and the damage zone surrounding the indentations were also related to the fluid properties.

  13. A hierarchy of computationally derived surgical and patient influences on metal on metal press-fit acetabular cup failure.

    PubMed

    Clarke, S G; Phillips, A T M; Bull, A M J; Cobb, J P

    2012-06-01

    The impact of anatomical variation and surgical error on excessive wear and loosening of the acetabular component of large diameter metal-on-metal hip arthroplasties was measured using a multi-factorial analysis through 112 different simulations. Each surgical scenario was subject to eight different daily loading activities using finite element analysis. Excessive wear appears to be predominantly dependent on cup orientation, with inclination error having a higher influence than version error, according to the study findings. Acetabular cup loosening, as inferred from initial implant stability, appears to depend predominantly on factors concerning the area of cup-bone contact, specifically the level of cup seating achieved and the individual patient's anatomy. The extent of press fit obtained at time of surgery did not appear to influence either mechanism of failure in this study. Copyright © 2012 Elsevier Ltd. All rights reserved.

  14. Space Shuttle Body Flap Actuator Bearing Testing for NASA Return to Flight

    NASA Technical Reports Server (NTRS)

    Jet, Timothy R.; Predmore, Roamer E.; Dube, Michael; Jones, William R., Jr.

    2006-01-01

    The Space Shuttle body flap (BF) is located beneath the main engine nozzles and is required for proper aerodynamic control during orbital descent. The body flap is controlled by four actuators connected by a common shaft and driven by the hydraulic power drive unit. Inspection of the actuators during refurbishment revealed three shaft bearings with unexpected damage. One was coated with black oxide on the balls and race wear surfaces, a second contained a relatively deep wear scar, and the third with scratches and an aluminum particle in the wear track. A shaft bearing life test program was initiated to measure the wear life and explain the 5.08-micrometer wear scar. A tribological analysis was conducted to demonstrate that the black oxide coated wear surfaces did not damage the bearing, interfere with the lubrication, or cause severe bearing wear. Pre-damaged (equivalent of 30 missions), commercial equivalent bearings and previously flown shaft bearings were tested at axial loads, speeds, and temperatures seen during flight operations. These bearing were successfully life tested at 60 C for 24 hours or 90 flights. With a safety factor of 4X, the bearings were qualified for 22 flights when only a maximum of 12 flights are expected. Additional testing at 23 C was performed to determine the lubricant life and to further understand the mechanism that caused the blackened balls. Test results indicating bearing life was shortened at a lower temperature surprised the investigators. Start\\Stop bearing testing that closely simulates mission profile was conducted at 23 C. Results of this testing showed lubricant life of 12 flights including a safety factor of four. Additional testing with bearings that have the equivalent of 30 missions of damage is being tested at 23 C. These tests are being performed over the Shuttle load profile to demonstrate the residual bearing life in the actuators exceeds 12 missions. Testing showed that the end of the shaft bearing life was characterized by bearing temperature rise, preload drop, and the onset of a severe wear bearing failure mechanism. The severe wear failure mechanism is characterized by rough wear scars, extensive bearing wear and steel transfer between the balls and the races.

  15. Role of EVA viscoelastic properties in the protective performance of a sport shoe: computational studies.

    PubMed

    Even-Tzur, Nurit; Weisz, Ety; Hirsch-Falk, Yifat; Gefen, Amit

    2006-01-01

    Modern sport shoes are designed to attenuate mechanical stress waves, mainly through deformation of the viscoelastic midsole which is typically made of ethylene vinyl acetate (EVA) foam. Shock absorption is obtained by flow of air through interconnected air cells in the EVA during shoe deformation under body-weight. However, when the shoe is overused and air cells collapse or thickness of the EVA is reduced, shock absorption capacity may be affected, and this may contribute to running injuries. Using lumped system and finite element models, we studied heel pad stresses and strains during heel-strike in running, considering the viscoelastic constitutive behavior of both the heel pad and EVA midsole. In particular, we simulated wear cases of the EVA, manifested in the modeling by reduced foam thickness, increased elastic stiffness, and shorter stress relaxation with respect to new shoe conditions. Simulations showed that heel pad stresses and strains were sensitive to viscous damping of the EVA. Wear of the EVA consistently increased heel pad stresses, and reduced EVA thickness was the most influential factor, e.g., for a 50% reduction in thickness, peak heel pad stress increased by 19%. We conclude that modeling of the heel-shoe interaction should consider the viscoelastic properties of the tissue and shoe components, and the age of the studied shoe.

  16. Effect of different dental ceramic systems on the wear of human enamel: An in vitro study.

    PubMed

    Zandparsa, Roya; El Huni, Rabie M; Hirayama, Hiroshi; Johnson, Marc I

    2016-02-01

    The wear of tooth structure opposing different advanced dental ceramic systems requires investigation. The purpose of this in vitro study was to compare the wear of advanced ceramic systems against human enamel antagonists. Four ceramic systems (IPS e.max Press, IPS e.max CAD, Noritake Super Porcelain EX-3, and LAVA Plus Zirconia) and 1 control group containing human enamel specimens were used in this study (n = 12). All specimens were fabricated as disks 11 mm in diameter and 3 mm thick. The mesiopalatal cusps of the maxillary third molars were prepared to serve as the enamel styluses. All specimens were embedded individually in 25 mm(3) autopolymerizing acrylic resin blocks. Wear was measured with a cyclic loading machine and a newly designed wear simulator. All enamel styluses (cusps) were scanned using the Activity 880 digital scanner (SmartOptics). Data from the base line and follow-up scans were collected and compared with Qualify 2012 3-dimensional (3D) and 2D digital inspection software (Geomagic), which aligned the models and detected the geometric changes and the wear caused by the antagonist specimen. One-way ANOVA was used to analyze the collected data. After 125,000 bidirectional loading cycles, the mean loss of opposing enamel volume for the enamel disks in the control group was 37.08 μm(3), the lowest mean value for IPS e.max Press system was 39.75 μm(3); 40.58 μm(3) for IPS e.max CAD; 45.08 μm(3) for Noritake Super Porcelain EX-3 system; and 48.66 μm(3) for the Lava Plus Zirconia system. No statically significant differences were found among the groups in opposing enamel volume loss (P=.225) or opposing enamel height loss (P=.149). In terms of opposing enamel height loss, Lava Plus Zirconia system showed the lowest mean value of 27.5 μm. The mean value for the IPS e.max CAD system was 27.91 μm; 29.08 μm for the control enamel; 33.25 μm for the IPS e.max Press system; and 34.75 μm for the Noritake Super Porcelain EX-3 system. Within the limitations of this in vitro study, no differences were found in the linear and volumetric reduction of enamel cusps abraded against enamel disks and all other ceramic specimens. All ceramic systems exhibited high durability and were wear-friendly to opposing enamel. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  17. STS-8 crewmembers during shuttle mission simulation training

    NASA Technical Reports Server (NTRS)

    1983-01-01

    Astronauts Guion S. Bluford, right, and Daniel C. Brandenstein man their respective Challenger entry and ascent stations in the Shutle Mission Simulator (SMS) at JSC. Brandenstein is in the pilot's station, while Bluford, a mission specialist, occupies one of the two aft flight deck seats. Both are wearing civilian clothes for this training exercise.

  18. Tribological characterisation of UHMWPE used in dual mobility total hip prosthesis

    NASA Astrophysics Data System (ADS)

    Essefi, I.; Hakkouna, H.; Ouenzerfi, G.; Mollon, G.; Hamza, S.; Renault, E.; Berthier, Y.; Trunfio-Sfarghiu, A.-M.

    2016-08-01

    Total hip arthroplasty represents an effective solution for bone and joint diseases. Nevertheless, the hip prosthesis has a limited lifetime, in the average around fifteen years. Their improvement, especially their dual mobility is the objective of this study. Therefore, our strategy is focused on improving the material by comparing three types of polyethylene to determine the best one from a friction mechanism and wear rate minimization standpoint. A dual mobility hip prosthesis, containing a two-sided steel and cobalt chrome cup, was tested with a TORNIER hip joint simulator in calf serum. The rubbed surfaces were characterized using scanning electron microscopy (SEM), contact angle measurements, atomic force microscopy (AFM) and confocal fluorescence microscopy. All these multiscale characterization techniques (from nanoscale to millimeter and micro- scale) showed that the velocity accommodation mechanism is different from one type of polyethylene to another. The wear in the case of standard polyethylene was noticeable and the particles were large and scattered between the surface of polyethylene, the surface of the cup and in the calf serum. For the crosslinked polyethylene, the particles coming from the wear, were not as large, but they were spread the same way as the first case. Even though it shares the same accommodation principle on the detachment of the material with the crosslinked polyethylene the wear particles for the crosslinked vitaminized polyethylene were large and they were only found on the surface of the polyethylene.

  19. Simulation of tibial counterface wear in mobile bearing knees with uncoated and ADLC coated surfaces.

    PubMed

    Jones, V C; Barton, D C; Auger, D D; Hardaker, C; Stone, M H; Fisher, J

    2001-01-01

    A multidirectional pin-on-plate reciprocating machine was used to compare the wear performance of UHMWPE sliding against cast cobalt chrome (CoCr) plates that were either untreated or coated with Amorphous Diamond Like Carbon (ADLC). The test conditions were based on a 1/5 scale model representative of in vivo motion at the tibial counterfaces of unconstrained mobile bearing knees. The average +/- STERR wear rates were 13.78+/-1.06 mm3/Mcycles for the ADLC counterfaces and 0.504+/-0.12 mm3/Mcycles for the control CoCr counterfaces. All of the pins run on the ADLC counterfaces exhibited the same patterns of blistering along the central axis, and severe abrasion elsewhere to the extent that all of the original machining marks were removed after just one week of testing. The average value of friction coefficient was 0.24 for the ADLC counterfaces and 0.073 for the control CoCr counterfaces. The factor of 3.5 increase was statistically significant at p < 0.05. In the tribological evaluation of ADLC coatings for tibial trays in mobile bearing knees, this study shows that this specific Physical Vapour Deposition (PVD) ADLC showed significantly poorer frictional and wear performance than uncoated surfaces which was sufficient to negate any potential benefits of improved resistance to third body damage.

  20. Modelling fire-fighter responses to exercise and asymmetric infrared radiation using a dynamic multi-mode model of human physiology and results from the sweating agile thermal manikin.

    PubMed

    Richards, M G M; Fiala, D

    2004-09-01

    In this study, predicted dynamic physiological responses are compared with wear trials results for firefighter suits: impermeable (A), semi-permeable (B) and permeable (C), and underwear. Wear trials consisted of three rest phases and two moderate work phases, with a frontal infrared (IR) radiation exposure of 500 W/m2 for the last 15 min of each work phase. Simulations were performed by detailed modelling of the experimental boundary conditions, including the inhomogeneous IR radiation combined with clothing properties for still and walking conditions measured using the Sweating Agile thermal Manikin. Accounting for the effect of sweat gland activity suppression with increased skin wettedness, the predicted total moisture loss was insignificantly different (P<0.05) from the wear trial value for suits B and C but was 37% too high for suit A. Predicted evolution of core, mean skin and local skin temperatures agreed well with the wear trial results for all clothing. Root mean square deviations ranged from 0.11 degrees C to 0.26 degrees C for core temperatures and from 0.28 degrees C to 0.38 degrees C for mean skin temperatures, which where typically lower than the experimental error. Transient thermodynamic processes occurring within suit A may account for the delayed/reduced fall in core temperature following exercise.

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhu, Bo; Zhao, Hongwei, E-mail: hwzhao@jlu.edu.cn, E-mail: khl69@163.com; Zhao, Dan

    It has always been a critical issue to understand the material removal behavior of Vibration-Assisted Machining (VAM), especially on atomic level. To find out the effects of vibration frequency on material removal response, a three-dimensional molecular dynamics (MD) model has been established in this research to investigate the effects of scratched groove, crystal defects on the surface quality, comparing with the Von Mises shear strain and tangential force in simulations during nano-scratching process. Comparisons are made among the results of simulations from different vibration frequency with the same scratching feed, depth, amplitude and crystal orientation. Copper potential in this simulationmore » is Embedded-Atom Method (EAM) potential. Interaction between copper and carbon atoms is Morse potential. Simulational results show that higher frequency can make groove smoother. Simulation with high frequency creates more dislocations to improve the machinability of copper specimen. The changing frequency does not have evident effects on Von Mises shear strain. Higher frequency can decrease the tangential force to reduce the consumption of cutting energy and tool wear. In conclusion, higher vibration frequency in VAM on mono-crystalline copper has positive effects on surface finish, machinablility and tool wear reduction.« less

  2. Rapid Analyses of Polyetheretherketone Wear Characteristics by Accelerated Wear Testing with Microfabricated Surfaces for Artificial Joint Systems

    PubMed Central

    Kuo, Chien-Wei

    2017-01-01

    Wear particle-induced biological responses are the major factors resulting in the loosening and then failure of total joint arthroplasties. It is feasible to improve the lubrication and reduce the wear of artificial joint system. Polyetheretherketone (PEEK) is considered as a potential bearing material due to its mechanical characteristics of resistance to fatigue strain. The PEEK wear particles have been indicated to be involved in biological responses in vitro, and further studies regarding the wear phenomena and wear particle generation are needed. In this study, we have established an accelerated wear testing system with microfabricated surfaces. Various contact pressures and lubricants have been utilized in the accelerated wear tests. Our results showed that increasing contact pressure resulted in an increase of wear particle sizes and wear rate, and the size of PEEK wear particles can be controlled by the feature size of microfabricated surfaces. These results provided the information rapidly about factors that affect the morphology and amount of PEEK wear particles and can be applied in the future for application of PEEK on the biological articulation system. PMID:29230411

  3. Rapid Analyses of Polyetheretherketone Wear Characteristics by Accelerated Wear Testing with Microfabricated Surfaces for Artificial Joint Systems.

    PubMed

    Su, Chen-Ying; Kuo, Chien-Wei; Fang, Hsu-Wei

    2017-01-01

    Wear particle-induced biological responses are the major factors resulting in the loosening and then failure of total joint arthroplasties. It is feasible to improve the lubrication and reduce the wear of artificial joint system. Polyetheretherketone (PEEK) is considered as a potential bearing material due to its mechanical characteristics of resistance to fatigue strain. The PEEK wear particles have been indicated to be involved in biological responses in vitro, and further studies regarding the wear phenomena and wear particle generation are needed. In this study, we have established an accelerated wear testing system with microfabricated surfaces. Various contact pressures and lubricants have been utilized in the accelerated wear tests. Our results showed that increasing contact pressure resulted in an increase of wear particle sizes and wear rate, and the size of PEEK wear particles can be controlled by the feature size of microfabricated surfaces. These results provided the information rapidly about factors that affect the morphology and amount of PEEK wear particles and can be applied in the future for application of PEEK on the biological articulation system.

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Panwar, Ranvir Singh, E-mail: ranvir.panwar@thapar.edu; Pandey, O.P., E-mail: oppandey@thapar.edu

    Particulate reinforced aluminum metal matrix composite is in high demand in automobile industry where the operational conditions vary from low to high temperature. In order to understand the wear mode at elevated temperature, this study was planned. For this purpose we developed a metal matrix composite containing aluminum alloy (LM13) as matrix and zircon sand as particulate reinforcement by stir casting process. Different amounts of zircon sand (5, 10, 15 and 20 wt.%) were incorporated in the matrix to study the effect of reinforcement on the wear resistance. Dispersion of zircon sand particles in the matrix was confirmed by usingmore » optical microscopy. Sliding wear tests were done to study the durability of the composite with respect to the base alloy. The effects of load and temperature on wear behavior from room temperature to 300 Degree-Sign C were studied to understand the wear mechanism deeply. Surface morphology of the worn surfaces after the wear tests as well as wear debris was observed under scanning electron microscope. Mild to severe wear transition was noticed in tests at high temperature and high load. However, there is interesting change in wear behavior of the composite near the critical temperature of the composite. All the observed behavior has been explained with reference to the observed microstructure of the wear track and debris. - Highlights: Black-Right-Pointing-Pointer Good interfacial bonding between zircon sand particles and Al matrix was observed. Black-Right-Pointing-Pointer The effect of temperature on the wear behavior of LM13/Zr composites was studied. Black-Right-Pointing-Pointer Wear resistance of the composite was improved with addition of zircon sand. Black-Right-Pointing-Pointer Transition temperature from mild to severe wear also improved in composite. Black-Right-Pointing-Pointer SEM analysis of the tracks and debris was done to establish wear mechanism.« less

  5. Development of helicopter transmission seals, task 2

    NASA Technical Reports Server (NTRS)

    Hayden, T. S.; Keller, C. H., Jr.

    1973-01-01

    High speed helicopter transmission seal concepts were designed, fabricated and tested. The concepts were a dual element split ring seal and a circumferential seal. The tests were performed in a rig using an actual input quill assembly. The test conditions were selected to simulate transmission operation and were 230 F oil temperature, and a sliding speed of 9400 ft/min. The split ring seal exhibited gross leakage and was considered unsatisfactory, while the circumferential seal leakage was less than 1 c.c./hour; this leakage is within acceptable limits. The circumferential seal wear was only to .0005 inches during a 100 hour run (40 starts and stops). During a 40 hour contamination test (mesh silica flour) the seal total wear was a maximum of .004 inches. This wear is considered acceptable.

  6. Abrasion Testing of Candidate Outer Layer Fabrics for Lunar EVA Space Suits

    NASA Technical Reports Server (NTRS)

    Mitchell, Kathryn

    2009-01-01

    During the Apollo program, the space suit outer layer fabrics were severely abraded after just a few Extravehicular Activities (EVAs). For example, the Apollo 12 commander reported abrasive wear on the boots, which penetrated the outer layer fabric into the thermal protection layers after less than eight hours of surface operations. Current plans for the Constellation Space Suit Element require the space suits to support hundreds of hours of EVA on the Lunar surface, creating a challenge for space suit designers to utilize materials advances made over the last forty years and improve upon the space suit fabrics used in the Apollo program. A test methodology has been developed by the NASA Johnson Space Center Crew and Thermal Systems Division for establishing comparative abrasion wear characteristics between various candidate space suit outer layer fabrics. The abrasion test method incorporates a large rotary drum tumbler with rocks and loose lunar simulant material to induce abrasion in fabric test cylinder elements, representative of what might occur during long term planetary surface EVAs. Preliminary materials screening activities were conducted to determine the degree of wear on representative space suit outer layer materials and the corresponding dust permeation encountered between subsequent sub-layers of thermal protective materials when exposed to a simulated worst case eight hour EVA. The test method was used to provide a preliminary evaluation of four candidate outer layer fabrics for future planetary surface space suit applications. This paper provides a review of previous abrasion studies on space suit fabrics, details the methodologies used for abrasion testing in this particular study, shares the results of the testing, and provides recommendations for future work.

  7. In vitro investigation of the performance of different restorative materials under cast circumferential clasps for removable dental prostheses.

    PubMed

    Pospiech, Peter; Nagel, Florian; Gebhart, Florian; Nothdurft, Frank P; Mitov, Gergo

    2012-12-01

    The objective of this in vitro study was to investigate the behavior of different composite restorative materials under the load of cast circumferential clasps for removable dental prostheses (RDPs). In 60 human molars, standardized mesial-occlusal-distal cavities were prepared. The cavities were restored with the following materials: Definite, Tetric Ceram, SureFil, Heliomolar RO, Ariston pHc, and Oralloy, and provided with a rest seat. The rest seats were subjected to 5,000 cycles of thermal cycling and 1,200,000 masticatory cycles in a mastication simulator via cobalt-chromium circumferential clasps cast to standardized frameworks in a laboratory model designed to simulate the biomechanics of a free-end denture base. Fracture analysis of the restorations was performed by light microscopy. Before and after loading, material wear was measured with a 3D-laser scanner, and an analysis of the marginal quality was performed in an SEM at ×200 applying the replica technique. No significant differences in the fracture behavior among the composite materials were found; the amalgam control group showed a significantly higher fracture resistance. Regarding the wear of the materials, the composites Definite and SureFil exhibited a behavior similar to that of amalgam. The other composites demonstrated higher wear rates. The initial marginal quality was significantly worse for Ariston pHc. The marginal adaptation decreased significantly after thermal and mechanical loading for Definite and Ariston pHc. In terms of the investigated aspects of mechanical performance, the tested composites seemed to be inferior to amalgam. Further clinical studies are needed to evaluate the ability of composite restorations to provide support for RDP clasps. The use of composites as direct restoration materials should be avoided in teeth, which serve as abutments for clasp-retained RDPs.

  8. Abrasion Testing of Candidate Outer Layer Fabrics for Lunar EVA Space Suits

    NASA Technical Reports Server (NTRS)

    Mitchell, Kathryn C.

    2010-01-01

    During the Apollo program, the space suit outer layer fabrics were badly abraded after just a few Extravehicular Activities (EVAs). For example, the Apollo 12 commander reported abrasive wear on the boots, which penetrated the outer layer fabric into the thermal protection layers after less than eight hours of surface operations. Current plans for the Constellation Space Suit Element require the space suits to support hundreds of hours of EVA on the Lunar surface, creating a challenge for space suit designers to utilize materials advances made over the last forty years and improve upon the space suit fabrics used in the Apollo program. A test methodology has been developed by the NASA Johnson Space Center Crew and Thermal Systems Division for establishing comparative abrasion wear characteristics between various candidate space suit outer layer fabrics. The abrasion test method incorporates a large rotary drum tumbler with rocks and loose lunar simulant material to induce abrasion in fabric test cylinder elements, representative of what might occur during long term planetary surface EVAs. Preliminary materials screening activities were conducted to determine the degree of wear on representative space suit outer layer materials and the corresponding dust permeation encountered between subsequent sub -layers of thermal protective materials when exposed to a simulated worst case eight hour EVA. The test method was used to provide a preliminary evaluation of four candidate outer layer fabrics for future planetary surface space suit applications. This Paper provides a review of previous abrasion studies on space suit fabrics, details the methodologies used for abrasion testing in this particular study, and shares the results and conclusions of the testing.

  9. Permethrin exposure from fabric-treated military uniforms under different wear-time scenarios.

    PubMed

    Proctor, Susan P; Maule, Alexis L; Heaton, Kristin J; Adam, Gina E

    2014-11-01

    The objective of the project was to ascertain whether urinary biomarkers of permethrin exposure are detected after wearing post-tailored, fabric-treated military uniforms under two different wear-time exposure scenarios. Study A occurred over 3.5 days and involved six participants wearing treated uniforms continuously for 30-32 h. Urine collection occurred at scheduled time points before, during, and after wearing the uniform. Study B, conducted over 19 days, included 11 participants wearing treated uniforms for 3 consecutive days, 8 h each day (with urine collection before, during, and after wear). Urinary biomarkers of permethrin (3-phenoxybenzoic acid (3PBA), cis- 2,2-(dichlorovinyl)-2,2-dimethylcyclopropane-1-carboxylic acid (cDCCA), trans- 2,2-(dichlorovinyl)-2,2-dimethylcyclopropane-1-carboxylic acid (tDCCA)) were detected during and after wear. Biomarker detection generally occurred over the 10- to 12-h period after putting on the uniform and subsided 24 h following uniform removal (in both Study A and B scenarios). Those wearing permethrin-treated uniforms under the longer wear-time scenario (Study A) excreted significantly higher cumulative mean levels compared with those in Study B (3.29 times higher for 3PBA and 2.23 times higher for the sum of c/tDCCA (P≤0.001)). Findings suggest that wearing permethrin-treated clothing does increase absorbed, internal dose levels of permethrin above population levels and is significantly related to wear-time duration.

  10. Clinical Biomechanics of Wear in Total Hip Arthroplasty

    PubMed Central

    Callaghan, John J; Pedersen, Douglas R; Johnston, Richard C; Brown, Thomas D

    2003-01-01

    Complementary clinical and laboratory studies were performed to identify variables associated with polyethylene wear following total hip replacement, and to elucidate the mechanisms responsible for accelerated wear in the total hip arthroplasty construct. Observational cohort studies were performed using a prospective clinical database of more than 4000 consecutive primary total hip arthroplasties performed by a single surgeon, to identify wear-related variables. These variables included head size, acetabular/femoral component impingement, and third body debris. Novel digital edge detection techniques were developed and employed to accurately measure wear, and to determine the relationships of head size and third body debris to acceleration of wear. A novel slidingdistance-coupled finite element model was formulated and employed to examine the mechanisms responsible for wear. The long-term cohort studies demonstrated smaller head sizes to be associated with less wear. Third body debris generated from cable fretting was associated with an increase in wear, osteolysis, and acetabular loosening, especially with larger head sizes. The sliding-distance-coupled finite element model replicated the wear rates occurring in vitro and in vivo, demonstrating the importance of sliding distance on polyethylene wear following total hip arthroplasty. It also demonstrated substantial increases in wear associated with femoral head scratching from third body debris. Further extension of the finite element formulation demonstrated the potential for acetabular component rim damage from impingement wear, and the enhanced potential for third body ingress to the bearing surface with larger head sizes. Edge detection wear measurement techniques demonstrated that early wear rates were predictive of long-term wear rates. These complementary clinical and laboratory investigations have provided insight into 1) the significance of sliding distance and physiologic loci of motion as contributing factors in minimizing wear, 2) the deleterious effects of third body particulates in accelerating wear, 3) the potential for, and factors related to, impingement wear, and 4) the potential advantages and compromises related to the use of larger head sizes in the bearing surface construct. PMID:14575243

  11. Does impaction of titanium-coated interbody fusion cages into the disc space cause wear debris or delamination?

    PubMed

    Kienle, Annette; Graf, Nicolas; Wilke, Hans-Joachim

    2016-02-01

    A large number of interbody fusion cages are made of polyetheretherketone (PEEK). To improve bone on-growth, some are coated with a thin layer of titanium. This coating may fail when subjected to shear loading. The purpose of this testing was to investigate whether impaction of titanium-coated PEEK cages into the disc space can result in wear or delamination of the coating, and whether titanium cages with subtractive surface etching (no coating) are less susceptible to such failure. A biomechanical study was carried out to simulate the impaction process in clinical practice and to evaluate if wear or delamination may result from impaction. Two groups of posterior lumbar interbody fusion cages with a similar geometry were tested: n=6 titanium-coated PEEK and n=6 surface-etched titanium cages. The cages were impacted into the space in between two vertebral body substitutes (polyurethane foam blocks). The two vertebral body substitutes were fixed in a device, through which a standardized axial preload of 390 N was applied. The anterior tip of the cage was positioned at the posterior border of the space between the two vertebral body substitutes. The cages were then inserted using a drop weight with a mass representative of a surgical hammer. The drop weight impacted the insertion instrument at a maximum speed of about 2.6 m/s, which is in the range of the impaction speed in vivo. This was repeated until the cages were fully inserted. The wear particles were captured and analyzed according to the pertinent standards. The surface-etched titanium cages did not show any signs of wear debris or surface damage. In contrast, the titanium-coated PEEK cages resulted in detached wear particles of different sizes (1-191 µm). Over 50% of these particles had a size <10 µm. In median, on 26% of the implants' teeth, the coating was abraded. Full delamination was not observed. In contrast to the surface-etched implants, the titanium-coated PEEK implants lost some coating material. This was visible to the naked eye. More than half of all particles were of a size range that allows phagocytosis. This study shows that titanium-coated implants are susceptible to impaction-related wear debris. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  12. In vivo contact kinematics and contact forces of the knee after total knee arthroplasty during dynamic weight-bearing activities.

    PubMed

    Varadarajan, Kartik M; Moynihan, Angela L; D'Lima, Darryl; Colwell, Clifford W; Li, Guoan

    2008-07-19

    Analysis of polyethylene component wear and implant loosening in total knee arthroplasty (TKA) requires precise knowledge of in vivo articular motion and loading conditions. This study presents a simultaneous in vivo measurement of tibiofemoral articular contact forces and contact kinematics in three TKA patients. These measurements were accomplished via a dual fluoroscopic imaging system and instrumented tibial implants, during dynamic single leg lunge and chair rising-sitting. The measured forces and contact locations were also used to determine mediolateral distribution of axial contact forces. Contact kinematics data showed a medial pivot during flexion of the knee, for all patients in the study. Average axial forces were higher for lunge compared to chair rising-sitting (224% vs. 187% body weight). In this study, we measured peak anteroposterior and mediolateral forces averaging 13.3% BW during lunge and 18.5% BW during chair rising-sitting. Mediolateral distributions of axial contact force were both patient and activity specific. All patients showed equitable medial-lateral loading during lunge but greater loads at the lateral compartment during chair rising-sitting. The results of this study may enable more accurate reproduction of in vivo loads and articular motion patterns in wear simulators and finite element models. This in turn may help advance our understanding of factors limiting longevity of TKA implants, such as aseptic loosening and polyethylene component wear, and enable improved TKA designs.

  13. Wear resistance of thick diamond like carbon coatings against polymeric materials used in single screw plasticizing technology

    NASA Astrophysics Data System (ADS)

    Zitzenbacher, G.; Liu, K.; Forsich, C.; Heim, D.

    2015-05-01

    Wear on the screw and barrel surface accompany polymer single screw plasticizing technology from the beginning. In general, wear on screws can be reduced by using nitrided steel surfaces, fused armour alloys on the screw flights and coatings. However, DLC-coatings (Diamond Like Carbon) comprise a number of interesting properties such as a high hardness, a low coefficient of friction and an excellent corrosion resistance due to their amorphous structure. The wear resistance of about 50 µm thick DLC-coatings against polyamide 6.6, polybutylene terephthalate and polypropylene is investigated in this paper. The tribology in the solids conveying zone of a single screw extruder until the beginning of melting is evaluated using a pin on disc tribometer and a so called screw tribometer. The polymeric pins are pressed against coated metal samples using the pin on disc tribometer and the tests are carried out at a defined normal force and sliding velocity. The screw tribometer is used to perform tribological experiments between polymer pellets and rotating coated metal shafts simulating the extruder screw. Long term experiments were performed to evaluate the wear resistance of the DLC-coating. A reduction of the coefficient of friction can be observed after a frictional distance of about 20 kilometers using glass fibre reinforced polymeric materials. This reduction is independent on the polymer and accompanied by a black layer on the wear surface of the polymeric pins. The DLC-coated metal samples show an up to 16 µm deep wear track after the 100 kilometer test period against the glass fiber filled materials only.

  14. STS-44 Atlantis, OV-104, MS Musgrave on FB-SMS middeck during JSC training

    NASA Technical Reports Server (NTRS)

    1991-01-01

    STS-44 Atlantis, Orbiter Vehicle (OV) 104, Mission Specialist (MS) F. Story Musgrave, wearing lightweight headset (HDST), adjusts controls on communications module mounted on a middeck overhead panel. Musgrave is on the middeck of the Fixed Base (FB) Shuttle Mission Simulator (SMS) located in JSC's Mission Simulation and Training Facility Bldg 5. The STS-44 crewmembers are participating in a flight simulation.

  15. Discontinuation of orthokeratology on eyeball elongation (DOEE).

    PubMed

    Cho, P; Cheung, S W

    2017-04-01

    To evaluate and compare changes in axial elongation, over a 14-month period, in subjects who discontinued and then resumed ortho-k lens wear with those who continued to wear their lenses or spectacles following a 2-year myopia control study. This single masked, prospective study recruited subjects who had just completed a 2-year myopia control study. Ortho-k subjects were classified as Group OKc, in which subjects continued ortho-k lens wear for the duration of the study; or Group OKd in which subjects discontinued lens wear for seven months and wore single-vision spectacles (Phase I) and then resumed ortho-k lens wear for another seven months (Phase II). Spectacle-wearing control subjects from the initial myopia control study continued wearing spectacles as control subjects. Axial lengths were measured at scheduled visits using the IOLMaster. Thirteen, 16, and 15 Control, OKc, and OKd subjects, aged 8-14 years, respectively completed the study. Significant increase in axial elongation was found in OKd subjects only in Phase I but not in Phase II. On resuming lens wear, in Phase II, the rate of axial elongation was no longer significantly different from those of the Control or OKc subjects. Stopping ortho-k lens wear at or before the age of 14 years led to a more rapid increase in axial length; comparable to those wearing spectacles during the initial 2-year myopia control study, but greater than the Control and OKc group in this study. Axial elongation slowed again with resumed lens wear after six months. Copyright © 2016 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  16. Influence of third-body particles originating from bone void fillers on the wear of ultra-high-molecular-weight polyethylene

    PubMed Central

    Cowie, Raelene M; Carbone, Silvia; Aiken, Sean; Cooper, John J; Jennings, Louise M

    2016-01-01

    Calcium sulfate bone void fillers are increasingly being used for dead space management in infected arthroplasty revision surgery. The presence of these materials as loose beads close to the bearing surfaces of joint replacements gives the potential for them to enter the joint becoming trapped between the articulating surfaces; the resulting damage to cobalt chrome counterfaces and the subsequent wear of ultra-high-molecular-weight polyethylene is unknown. In this study, third-body damage to cobalt chrome counterfaces was simulated using particles of the calcium sulfate bone void fillers Stimulan® (Biocomposites Ltd., Keele, UK) and Osteoset® (Wright Medical Technology, TN, USA) using a bespoke rig. Scratches on the cobalt chrome plates were quantified in terms of their density and mean lip height, and the damage caused by the bone void fillers was compared to that caused by particles of SmartSet GMV PMMA bone cement (DePuy Synthes, IN, USA). The surface damage from Stimulan® was below the resolution of the analysis technique used; SmartSet GMV caused 0.19 scratches/mm with a mean lip height of 0.03 µm; Osteoset® led to a significantly higher number (1.62 scratches/mm) of scratches with a higher mean lip height (0.04 µm). Wear tests of ultra-high-molecular-weight polyethylene were carried out in a six-station multi-axial pin on plate reciprocating rig against the damaged plates and compared to negative (highly polished) and positive control plates damaged with a diamond stylus (2 µm lip height). The wear of ultra-high-molecular-weight polyethylene was shown to be similar against the negative control plates and those damaged with third-body particles; there was a significantly higher (p < 0.001) rate of ultra-high-molecular-weight polyethylene wear against the positive control plates. This study showed that bone void fillers of similar composition can cause varying damage to cobalt chrome counterfaces. However, the lip heights of the scratches were not of sufficient magnitude to increase the wear of ultra-high-molecular-weight polyethylene above that of the negative controls. PMID:27312481

  17. Compatibility of the totally replaced hip. Reduction of wear by amorphous diamond coating.

    PubMed

    Santavirta, Seppo

    2003-12-01

    Particulate wear debris in totally replaced hips causes adverse local host reactions. The extreme form of such a reaction, aggressive granulomatosis, was found to be a distinct condition and different from simple aseptic loosening. Reactive and adaptive tissues around the totally replaced hip were made of proliferation of local fibroblast like cells and activated macrophages. Methylmethacrylate and high-molecular-weight polyethylene were shown to be essentially immunologically inert implant materials, but in small particulate form functioned as cellular irritants initiating local biological reactions leading to loosening of the implants. Chromium-cobalt-molybdenum is the most popular metallic implant material; it is hard and tough, and the bearings of this metal are partially self-polishing. In total hip implants, prerequisites for longevity of the replaced hip are good biocompatibility of the materials and sufficient tribological properties of the bearings. The third key issue is that the bearing must minimize frictional shear at the prosthetic bone-implant interface to be compatible with long-term survival. Some of the approaches to meet these demands are alumina-on-alumina and metal-on-metal designs, as well as the use of highly crosslinked polyethylene for the acetabular component. In order to avoid the wear-based deleterious properties of the conventional total hip prosthesis materials or coatings, the present work included biological and tribological testing of amorphous diamond. Previous experiments had demonstrated that a high adhesion of tetrahedral amorphous carbon coatings to a substrate can be achieved by using mixing layers or interlayers. Amorphous diamond was found to be biologically inert, and simulator testing indicated excellent wear properties for conventional total hip prostheses, in which either the ball or both bearing surfaces were coated with hydrogen-free tetrahedral amorphous diamond films. Simulator testing with such total hip prostheses showed no measurable wear or detectable delamination after 15,000,000 test cycles corresponding to 15 years of clinical use. The present work clearly shows that wear is one of the basic problems with totally replaced hips. Diamond coating of the bearing surfaces appears to be an attractive solution to improve longevity of the totally replaced hip.

  18. Microstructure, mechanical and fretting wear properties of TiC-stainless steel composites

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Akhtar, F.; Department of Metallurgical and Materials Engineering, University of Engineering and Technology, Lahore; Guo, S.J.

    2008-01-15

    This study deals with the processing, microstructure, and wear behavior of TiC-reinforced stainless steel matrix composites, containing 50 to 70 wt.% TiC. Powder technology was used to successfully fabricate the composites. The microstructure of the composite was characterized by scanning electron microscopy. The microstructural study revealed that the TiC particles were distributed uniformly in the steel matrix phase. Interface debonding and microcracks were not observed in the composite. The composite hardness increased with TiC content. The fretting wear resistance of the composites was studied against high speed steel. The wear mechanisms are discussed by means of microscopical observations on themore » worn surfaces. The wear was severe at higher wear loads and lower TiC content. Microplowing of the stainless steel matrix was found to be the dominant wear mechanism. Heavy microplowing and rapid removal of material from the wear surface was observed at high wear load. The variation of wear loss with volume fraction and mean free path of the binder phase is also reported.« less

  19. Wear mechanisms and improvements of wear resistance in cobalt-chromium alloy femoral components in artificial total knee joints

    NASA Astrophysics Data System (ADS)

    Que, Like

    Wear is one of the major causes of artificial total knee arthroplasty (TKA) failure. Wear debris can cause adverse reactions to the surrounding tissue which can ultimately lead to loosening of the prosthesis. The wear behavior of UHMWPE tibial components have been studied extensively, but relatively little attention has been paid to the CoCrMo femoral component. The goal of the present study was to investigate the wear mechanisms of CoCrMo femoral components, to study the effect of CoCrMo alloy surface roughness on the wear of UHMWPE, and to determine the effect of heat treatments on the wear resistance of the CoCrMo implant alloys. The surface roughness of twenty-seven retrieved CoCrMo femoral components was analyzed. A multiple station wear testing machine and a wear fixture attached to an MTS 858 bionix system were built and used for in vitro wear studies of the CoCrMo/UHMWPE bearing couple. Solution and aging treatments were applied to the CoCrMo alloys. A white light interference surface profilometer (WLISP) and a scanning electron microscope (SEM) were used to measure the surface roughness and to study wear mechanisms of CoCrMo alloy. An optical microscope was used for alloy microstructure study. X-ray diffraction tests were performed to identify alloy phase transformation after aging. The micro-structure, hardness, and wear resistance of the alloys were studied. Surface roughness was used to quantify alloy wear, and the minimum number of surface roughness measurements required to obtain a reliable and repeatable characterization of surface roughness for a worn alloy surface was determined. The surfaces of the retrieved CoCrMo femoral components appeared to be damaged by metal particles embedded in the UHMWPE tibial component and metal-on-metal wear due to UHMWPE tibial component through-wear. Surface roughness of the femoral components was not correlated with patient age, weight, sex, or length of implantation. In vitro wear tests showed that when the CoCrMo alloy surface roughness was higher than 0.022 mum Ra (surface roughness average), UHMWPE wear increased with increasing CoCrMo alloy surface roughness. Bone and poly(methyl methacrylate) (PMMA) bone cement abrasive particles created scratches on the alloy via a ploughing mechanism, and resulted in significantly rougher surfaces than controls without particles (P < 0.01). Solution treatments at 1230sp°C and 1245sp°C reduced the hardness and wear resistance of the as-cast F75 CoCrMo alloy. Aging at 700sp°C caused recrystallization of the forged F799 alloy and improved wear resistance. Thermo-mechanical treatments have the potential to increase the lifetime of artificial joints by increasing the wear resistance of CoCrMo components.

  20. Tribological characteristics of a composite total-surface hip replacement

    NASA Technical Reports Server (NTRS)

    Jones, W. R., Jr.; Roberts, J. C.; Ling, F. F.

    1982-01-01

    Continuous fiber, woven E glass composite femoral shells having the same elastic properties as bone were fabricated. The shells were then encrusted with filled epoxy wear resistant coatings and run dry against ultrahigh molecular weight polyethylene acetabular cups in 42,000 and 250,000 cycle wear tests on a total hip simulator. The tribological characteristics of these continuous fiber particulate composite femoral shells articulating with ultrahigh molecular weight polyethylene acetabular cups were comparable to those of a vitallium ball articulating with an ultrahigh molecular weight polyethylene acetabular cup.

  1. Numerical Simulation of Wear in a C/C Composite Multidisk Clutch (Preprint)

    DTIC Science & Technology

    2009-04-01

    subroutine FRIC, in the commercial finite element software ( ABAQUS , 6.5-1, Pawtucket, RI) [25], to calculate the local wear depth increment (decrease in...temperature continuity and the heat balance conditions must be satisfied. The subroutine FRIC in ABAQUS code [25] is called only when the contact point is...0.33, thermal expansion coefficients αr = 0.31x10-6/K, αz = 0.29x10-6/K, friction coefficient µ = 0.20, heat convection coefficient h = 100 W/m2K

  2. Dental wear quantity and direction in Chalcolithic and Medieval populations from southwest France.

    PubMed

    Grimoud, Anne-Marie; Gibbon, Victoria E

    2017-01-01

    The aim of this study was to verify if dental wear changed due to the dietary shift between the Chalcolithic and Middle Ages from relatively hard and fibrous foods to soft cooked cereals. This was accomplished by comparing dental wear quantity and direction between people from two archaeological sites, Les Treilles during the Chalcolithic (mixed subsistence farmers) and Marsan from the Middle Ages (agriculturalists) in southwest France. The materials studied include 65 mandibles, 32 from Les Treilles and 33 from Marsan; 549 teeth were studied. The results show statistically significant difference in wear quantity and direction, the Chalcolithic population (Les Treilles) had the greatest levels of wear in a mainly oblique direction, with the anterior teeth heavily affected by wear. Comparatively, the Medieval sample (Marsan) had lesser levels of wear in a mainly horizontal direction, and the most heavily worn teeth were the molars and incisors. The quantity of wear seems to correlate well with changes in diet, the high level of wear on the anterior teeth in the Chalcolithic sample corresponds with the consumption of a mixed diet of fibrous and tough foods. At Marsan, the lower wear quantity was likely due to a diet of soft boiled cereals, requiring less mastication. However, wear direction appears dependent on several factors and may correlate with more mixed subsistence practices. This study demonstrates the need for additional research into the complex actions of mastication and its effect on dental wear, as well as standardised methodology for the examination of dental wear in archaeological samples. Copyright © 2016 Elsevier GmbH. All rights reserved.

  3. STS-27 Atlantis - OV-104, Commander Gibson on SMS forward flight deck

    NASA Image and Video Library

    1988-02-03

    STS-27 Atlantis, Orbiter Vehicle (OV) 104, Commander Robert L. Gibson, wearing flight coveralls and communications kit assembly, sits at commanders station controls on JSC shuttle mission simulator (SMS) forward flight deck during training session. Gibson looks at crewmember on aft flight deck. SMS is located in the Mission Simulation and Training Facility Bldg 5.

  4. Mechanical properties and bio-tribological behaviors of novel beta-Zr-type Zr-Al-Fe-Nb alloys for biomedical applications.

    PubMed

    Hua, Nengbin; Chen, Wenzhe; Zhang, Lei; Li, Guanghui; Liao, Zhenlong; Lin, Yan

    2017-07-01

    The present study prepares novel Zr 70+x Al 5 Fe 15-x Nb 10 (x=0, 5) alloys by arc-melting for potential biomedical application. The mechanical properties and bio-tribological behaviors of the Zr-based alloys are evaluated and compared with biomedical pure Zr. The as-prepared alloys exhibit a microstructure containing a micrometer-sized dendritic beta-Zr phase dispersed in a Zr 2 Fe-typed matrix. It is found that increasing the content of Zr is favorable for the mechanical compatibility with a combination of low Young's modulus, large plasticity, and high compressive strength. The wear resistance of the Zr-Al-Fe-Nb alloys in air and phosphate buffer saline (PBS) solution is superior to that of pure Zr. The wear mechanism of Zr-based alloys sliding in air is controlled by oxidation and abrasive wear whereas that sliding in PBS is controlled by synergistic effects of the abrasive and corrosive wear. Electrochemical measurements demonstrate that the Zr-based alloys are corrosion resistant in PBS. Their bio-corrosion resistance is improved with the increase in Zr content, which is attributed to the enrichment in Zr and decrease in Al concentration in the surface passive film of alloys. The Zr 75 Al 5 Fe 10 Nb 10 exhibits the best corrosion resistance in PBS, which contributes to its superior wear resistance in a simulated body environment. The combination of good mechanical properties, corrosion resistance, and biotribological behaviors of the Zr-Al-Fe-Nb alloys offers them potential advantages in biomedical applications. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Wear Properties of ECAP-Processed AM80 Magnesium Alloy

    NASA Astrophysics Data System (ADS)

    Gopi, K. R.; Shivananda Nayaka, H.; Sahu, Sandeep

    2017-07-01

    AM80 magnesium alloy was subjected to equal-channel angular pressing (ECAP), and microstructural evolution was studied using scanning electron microscope (SEM). Grain size was found to decrease up to 3 µm after four passes. An increase in number of ECAP passes led to a corresponding increase in hardness of the processed samples. Unprocessed and ECAP-processed samples were subjected to wear test using pin-on-disk wear test machine to study the wear behavior. Effects of varying loads (30 and 40 N) with sliding distances (2500 and 5000 m) were studied. The results showed reduction in wear mass loss for the ECAP-processed samples in comparison with unprocessed condition. Coefficient of friction (COF) was studied for different loads, and improvement in COF values was observed for ECAP-processed samples compared to unprocessed condition. Worn surfaces were studied using SEM and energy-dispersive x-ray spectrometer, and they exhibited plastic deformation, delamination, plowing, wear debris and oxidation in the sliding direction. X-ray diffraction analysis was conducted on the worn surfaces to identify the phases. It revealed the presence of magnesium oxide and magnesium aluminum oxide which led to oxidation wear in the sliding direction. Wear mechanism was found to be abrasive and oxidation wear.

  6. Wear and Corrosion Interactions at the Titanium/Zirconia Interface: Dental Implant Application.

    PubMed

    Sikora, Craig L; Alfaro, Maria F; Yuan, Judy Chia-Chun; Barao, Valentim A; Sukotjo, Cortino; Mathew, Mathew T

    2018-03-09

    Dental implants have been shown to have predictable success, but esthetic complications often arise. To reduce tissue shadowing from titanium, zirconia abutments may be used; however, the literature suggests that the use of zirconia leads to greater destruction of the implant interface that may result in biological complications such as titanium tattoos and heavy metal toxicity. Previous studies have examined the mechanical aspects of this implant/abutment relationship, but they have not accounted for the corrosive degradation that also takes place in the dynamic environment of the oral cavity. This study investigated the combined effect of both wear and corrosion on the materials at the implant and abutment interface. Using a simulated oral tribocorrosive environment, titanium (Ti) and zirconia (Zr) abutment materials were slid against titanium and Roxolid implant alloys. The four couplings (Ti/Ti, Ti/Rox, Zr/Ti, Zr/Rox) were selected for the tribocorrosion tests (N = 3). The testing was conducted for 25K cycles, and the coefficient of friction (CoF) and voltage evolution were recorded simultaneously. Following the tribocorrosion assays, the wear volume loss was calculated, and surface characterization was performed. Statistical analysis was completed using a one-way ANOVA followed by post-hoc Bonferroni comparisons. Zr/Ti groups had the highest CoF (1.1647), and Ti/Ti had the lowest (0.5033). The Zr/Ti coupling generated significantly more mechanical damage than the Ti/Ti group (p = 0.021). From the corrosion aspect, the Ti/Ti groups had the highest voltage drop (0.802 V), indicating greater corrosion susceptibility. In comparison, the Zr/Roxolid group had the lowest voltage drop (0.628 V) and significantly less electrochemical degradation (p = 0.019). Overall, the Ti/Ti group had the largest wear volume loss (15.1 × 10 7 μm 3 ), while the Zr/Ti group had the least volume loss (2.26 × 10 7 μm 3 ). Both zirconia couplings had significantly less wear volume than the titanium couplings (p < 0.001). This study highlights the synergistic interaction between wear and corrosion, which occurs when masticatory forces combine with the salivary environment of the oral cavity. Overall, the zirconia groups outperformed the titanium groups. In fact, the titanium groups generated 5 to 6 times more wear to the implant alloys as compared with the zirconia counterparts. The best performing group was Zr/Ti, and the worst performing group was Ti/Ti. © 2018 by the American College of Prosthodontists.

  7. A novel recession rate physics methodology for space applications at CIRA by means of CIRCE radioactive beam tracers

    NASA Astrophysics Data System (ADS)

    De Cesare, M.; Di Leva, A.; Del Vecchio, A.; Gialanella, L.

    2018-03-01

    Thermal protection systems (TPSs) of spacecrafts, either for single use or reusable, experience wear by ablation and erosion, due to the high heat fluxes during a re-entry phase in the atmosphere. The determination of the wear rate is a crucial point, which is presently mainly possible in aerospace on-ground measurements by means of invasive diagnostics. The purpose of this paper is to present novel contactless, online, high-sensitivity and non-intrusive diagnostics for wear measurements based on radioactive tracers. We propose the technique for future on-ground experiments that might later be developed to perform in-flight TPSs monitoring, thus significantly increasing the safety of the aerospace vehicles. The basic ideas of the method, its sensitivity investigated by GEANT4 simulations, and the future experimental validation are outlined.

  8. Investigation of wear resistance of polyurethanes in abrasive soil mass

    NASA Astrophysics Data System (ADS)

    Napiórkowski, Jerzy; Ligier, Krzysztof

    2018-04-01

    This paper presents a comparative study of polyurethane wear in different abrasive soil masses. Two types of polyurethanes of various chemical compositions and untreated 38GSA steel were tested, the latter being used as a reference standard. The study was conducted in natural soil mass at a "rotating bowl" stand. Relative wear resistance was determined from measurements of mass wear for the materials under study. The condition of the surface of the materials under wear test was analysed.

  9. Dynamic SEM wear studies of tungsten carbide cermets. [friction and wear experiments

    NASA Technical Reports Server (NTRS)

    Brainard, W. A.; Buckley, D. H.

    1975-01-01

    Dynamic friction and wear experiments were conducted in a scanning electron microscope. The wear behavior of pure tungsten carbide and composite with 6 and 15 weight percent cobalt binder was examined, and etching of the binder was done to selectively determine the role of the binder in the wear process. Dynamic experiments were conducted as the tungsten carbide (WC) and bonded WC cermet surfaces were transversed by a 50 micron radiused diamond stylus. These studies show that the predominant wear process in WC is fracture initiated by plastic deformation, and the wear of the etched cermets is similar to pure WC. The presence of the cobalt binder reduces both friction and wear. The cementing action of the cobalt reduces granular separation, and promotes a dense polished layer because of its low shear strength film-forming properties. The wear debris generated from unetched surface is approximately the same composition as the bulk.

  10. Anti-wear Mechanism Analysis of Nano-CaCO3 Additives

    NASA Astrophysics Data System (ADS)

    Xu, Zhen; Sun, Junfeng

    2018-06-01

    In this paper, the wear test was carried on with cylinder piston by the wear test device, receiving the results of the piston ring wear and abrasive characteristics by monitoring the wear process, the thesis analysis and put forward the nano-CaCO3 lubricating oil additive anti wear mechanism by the ferrography analysis technology, and provide the technical reference for the relevant measures to reduce wear and the friction, and provide reference value for further study on the related theories of reducing wear and reducing friction.

  11. "Why Does Wearing a Yellow Bib Make Us Different"?: A Case Study of Explaining Discrimination in a West of Scotland Secondary (High) School

    ERIC Educational Resources Information Center

    Maitles, Henry; McKelvie, Erin

    2010-01-01

    This paper reports on and discusses one Scottish secondary school's attempts to develop an understanding of discrimination and prejudice with S1 (Year 7 in England) pupils using a simulation based on a truncated version of Jane Elliott's "Blue Eyes/Brown Eyes" experiment of the 1960s. The research questions were: (1) Did the pupils learn…

  12. Wear Characteristics of Ni-Based Hardfacing Alloy Deposited on Stainless Steel Substrate by Laser Cladding

    NASA Astrophysics Data System (ADS)

    Awasthi, Reena; Limaye, P. K.; Kumar, Santosh; Kushwaha, Ram P.; Viswanadham, C. S.; Srivastava, Dinesh; Soni, N. L.; Patel, R. J.; Dey, G. K.

    2015-03-01

    In this study, dry sliding wear characteristics of the Ni-based hardfacing alloy (Ni-Mo-Cr-Si) deposited on stainless steel SS316L substrate by laser cladding have been presented. Dry sliding wear behavior of the laser clad layer was evaluated against two different counter bodies, AISI 52100 chromium steel (~850 VHN) and tungsten carbide ball (~2200 VHN) to study both adhesive and abrasive wear characteristics, in comparison with the substrate SS316L using ball on plate reciprocating wear tester. The wear resistance was evaluated as a function of load and sliding speed for a constant sliding amplitude and sliding distance. The wear mechanisms were studied on the basis of wear surface morphology and microchemical analysis of the wear track using SEM-EDS. Laser clad layer of Ni-Mo-Cr-Si on SS316L exhibited much higher hardness (~700 VHN) than that of substrate SS316L (~200 VHN). The laser clad layer exhibited higher wear resistance as compared to SS316L substrate while sliding against both the counterparts. However, the improvement in the wear resistance of the clad layer as compared to the substrate was much higher while sliding against AISI 52100 chromium steel than that while sliding against WC, at the same contact stress intensity.

  13. STS-29 Commander Coats in JSC fixed base (FB) shuttle mission simulator (SMS)

    NASA Technical Reports Server (NTRS)

    1986-01-01

    STS-29 Discovery, Orbiter Vehicle (OV) 103, Commander Michael L. Coats sits at commanders station forward flight deck controls in JSC fixed base (FB) shuttle mission simulator (SMS). Coats, wearing communications kit assembly headset and flight coveralls, looks away from forward control panels to aft flight deck. Pilots station seat back appears in foreground. FB-SMS is located in JSC Mission Simulation and Training Facility Bldg 5.

  14. STS-26 Commander Hauck in fixed based (FB) shuttle mission simulator (SMS)

    NASA Technical Reports Server (NTRS)

    1988-01-01

    STS-26 Discovery, Orbiter Vehicle (OV) 103, Commander Frederick H. Hauck, wearing comunications kit assembly headset and seated in the commanders seat on forward flight deck, looks over his shoulder toward the aft flight deck. A flight data file (FDF) notebook rests on his lap. The STS-26 crew is training in the fixed base (FB) shuttle mission simulator (SMS) located in JSC Mission Simulation and Training Facility Bldg 5.

  15. Modelling of Tool Wear and Residual Stress during Machining of AISI H13 Tool Steel

    NASA Astrophysics Data System (ADS)

    Outeiro, José C.; Umbrello, Domenico; Pina, José C.; Rizzuti, Stefania

    2007-05-01

    Residual stresses can enhance or impair the ability of a component to withstand loading conditions in service (fatigue, creep, stress corrosion cracking, etc.), depending on their nature: compressive or tensile, respectively. This poses enormous problems in structural assembly as this affects the structural integrity of the whole part. In addition, tool wear issues are of critical importance in manufacturing since these affect component quality, tool life and machining cost. Therefore, prediction and control of both tool wear and the residual stresses in machining are absolutely necessary. In this work, a two-dimensional Finite Element model using an implicit Lagrangian formulation with an automatic remeshing was applied to simulate the orthogonal cutting process of AISI H13 tool steel. To validate such model the predicted and experimentally measured chip geometry, cutting forces, temperatures, tool wear and residual stresses on the machined affected layers were compared. The proposed FE model allowed us to investigate the influence of tool geometry, cutting regime parameters and tool wear on residual stress distribution in the machined surface and subsurface of AISI H13 tool steel. The obtained results permit to conclude that in order to reduce the magnitude of surface residual stresses, the cutting speed should be increased, the uncut chip thickness (or feed) should be reduced and machining with honed tools having large cutting edge radii produce better results than chamfered tools. Moreover, increasing tool wear increases the magnitude of surface residual stresses.

  16. Comparability of clinical wear measurements by optical 3D laser scanning in two different centers.

    PubMed

    Stober, Thomas; Heuschmid, Navina; Zellweger, Gaby; Rousson, Valentin; Rues, Stefan; Heintze, Siegward D

    2014-05-01

    The purpose of this study was to compare the use of different variables to measure the clinical wear of two denture tooth materials in two analysis centers. Twelve edentulous patients were provided with full dentures. Two different denture tooth materials (experimental material and control) were placed randomly in accordance with the split-mouth design. For wear measurements, impressions were made after an adjustment phase of 1-2 weeks and after 6, 12, 18, and 24 months. The occlusal wear of the posterior denture teeth of 11 subjects was assessed in two study centers by use of plaster replicas and 3D laser-scanning methods. In both centers sequential scans of the occlusal surfaces were digitized and superimposed. Wear was described by use of four different variables. Statistical analysis was performed after log-transformation of the wear data by use of the Pearson and Lin correlation and by use of a mixed linear model. Mean occlusal vertical wear of the denture teeth after 24 months was between 120μm and 212μm, depending on wear variable and material. For three of the four variables, wear of the experimental material was statistically significantly less than that of the control. Comparison of the two study centers, however, revealed correlation of the wear variables was only moderate whereas strong correlation was observed among the different wear variables evaluated by each center. Moderate correlation was observed for clinical wear measurements by optical 3D laser scanning in two different study centers. For the two denture tooth materials, wear measurements limited to the attrition zones led to the same qualitative assessment. Copyright © 2014 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  17. Wear of sharp aggregates in a rotating drum

    NASA Astrophysics Data System (ADS)

    Deiros Quintanilla, Ivan; Combe, Gaël; Emeriault, Fabrice; Toni, Jean-Benoît; Voivret, Charles; Ferellec, Jean François

    2017-06-01

    Aggregates constituting ballast layer wear due to the continuous passage of trains and during the necessary maintenance operations of the track. In order to develop efficient solutions for ballasted tracks design and maintenance, a proper knowledge of the degradation laws of ballast grains is needed. In tribology, the amount of wear due to friction when two surfaces are in contact is classically predicted by Archard's equation. However, due to the continuous evolution of grain angularity and roughness, at the macro-scale wear coefficient cannot be assumed to remain constant, but will depend on the state of degradation of the grain surface. In order to adjust the model to this particular case, the Micro-Deval Attrition test is used. The rotating drum is stopped at intermediate stages and the amount of generated fine particles is measured. Thus the curve of mass loss along time is built. These results are then linked to Archard's model using the values of contact forces and relative displacements extracted from discrete element simulations. Finally, a morphology analysis is performed tracking shape and roughness parameters at different stages of degradation using X-ray tomography and a laser profilometer.

  18. Electrochemical corrosion, wear and cell behavior of ZrO2/TiO2 alloyed layer on Ti-6Al-4V.

    PubMed

    Li, Jianfang; He, Xiaojing; Zhang, Guannan; Hang, Ruiqiang; Huang, Xiaobo; Tang, Bin; Zhang, Xiangyu

    2018-06-01

    Ti-6Al-4V (TC4) has received increasing attention as biomaterial but also raised concerns about the long-term safety of releasing of metal ions and poor wear resistance. In this work, an ZrO 2 /TiO 2 alloyed layer was prepared on TC4 by plasma surface alloying with Zr and subsequently annealed in the air for improved corrosion and wear resistant. To assess the corrosion performance of the alloyed layer, the specimens were measured by open circuit potential, electrochemical impedance spectroscopy and potentiodynamic polarization in simulated body fluid solution. The result shows that the ZrO 2 /TiO 2 alloyed layer exhibits strikingly high polarization resistance, wide passive region and very low current density, indicating the excellent corrosion resistance. The layer also displays significant improvement of wear resistance. Furthermore, the alloyed layer restricts cell adhesion and spreading. We infer that the ZrO 2 /TiO 2 alloyed layer might be potentially useful implanted devices such as biosensors, bioelectronics or drug delivery devices. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. Improving tribological properties of Ti-5Zr-3Sn-5Mo-15Nb alloy by double glow plasma surface alloying

    NASA Astrophysics Data System (ADS)

    Guo, Lili; Qin, Lin; Kong, Fanyou; Yi, Hong; Tang, Bin

    2016-12-01

    Molybdenum, an alloying element, was deposited and diffused on Ti-5Zr-3Sn-5Mo-15Nb (TLM) substrate by double glow plasma surface alloying technology at 900, 950 and 1000 °C. The microstructure, composition distribution and micro-hardness of the Mo modified layers were analyzed. Contact angles on deionized water and wear behaviors of the samples against corundum balls in simulated human body fluids were investigated. Results show that the surface microhardness is significantly enhanced after alloying and increases with treated temperature rising, and the contact angles are lowered to some extent. More importantly, compared to as-received TLM alloy, the Mo modified samples, especially the one treated at 1000 °C, exhibit the significant improvement of tribological properties in reciprocating wear tests, with lower specific wear rate and friction coefficient. To conclude, Mo alloying treatment is an effective approach to obtain excellent comprehensive properties including optimal wear resistance and improved wettability, which ensure the lasting and safety application for titanium alloys as the biomedical implants.

  20. Microstructure analysis and wear behavior of titanium cermet femoral head with hard TiC layer.

    PubMed

    Luo, Yong; Ge, Shirong; Liu, Hongtao; Jin, Zhongmin

    2009-12-11

    Titanium cermet was successfully synthesized and formed a thin gradient titanium carbide coating on the surface of Ti6Al4V alloy by using a novel sequential carburization under high temperature, while the titanium cermet femoral head was produced. The titanium cermet phase and surface topography were characterized with X-ray diffraction (XRD) and backscattered electron imaging (BSE). And then the wear behavior of titanium cermet femoral head was investigated by using CUMT II artificial joint hip simulator. The surface characterization indicates that carbon effectively diffused into the titanium alloys and formed a hard TiC layer on the Ti6Al4V alloys surface with a micro-porous structure. The artificial hip joint experimental results show that titanium cermet femoral head could not only improve the wear resistance of artificial femoral head, but also decrease the wear of UHMWPE joint cup. In addition, the carburized titanium alloy femoral head could effectively control the UHMWPE debris distribution, and increase the size of UHMWPE debris. All of the results suggest that titanium cermet is a prospective femoral head material in artificial joint.

  1. Bedrock erosion by sliding wear in channelized granular flow

    NASA Astrophysics Data System (ADS)

    Hung, C. Y.; Stark, C. P.; Capart, H.; Smith, B.; Maia, H. T.; Li, L.; Reitz, M. D.

    2014-12-01

    Boundary forces generated by debris flows can be powerful enough to erode bedrock and cause considerable damage to infrastructure during runout. Bedrock wear can be separated into impact and sliding wear processes. Here we focus on sliding wear. We have conducted experiments with a 40-cm-diameter grainflow-generating rotating drum designed to simulate dry channelized debris flows. To generate sliding erosion, we placed a 20-cm-diameter bedrock plate axially on the back wall of the drum. The rotating drum was half filled with 2.3-mm-diameter grains, which formed a thin grain-avalanching layer with peak flow speed and depth close to the drum axis. The whole experimental apparatus was placed on a 100g-ton geotechnical centrifuge and, in order to scale up the stress level, spun to a range of effective gravity levels. Rates and patterns of erosion of the bedrock plate were mapped after each experiment using 3d micro-photogrammetry. High-speed video and particle tracking were employed to measure granular flow dynamics. The resulting data for granular velocities and flow geometry were used to estimate impulse exchanges and forces on the bedrock plate. To address some of the complexities of granular flow under variable gravity levels, we developed a continuum model framed around a GDR MiDi rheology. This model allowed us to scale up boundary forcing while maintaining the same granular flow regime, and helped us to understand important aspects of the flow dynamics including e.g. fluxes of momentum and kinetic energy. In order to understand the detailed processes of boundary forcing, we performed numerical simulations with a new contact dynamics model. This model confirmed key aspects of our continuum model and provided information on second-order behavior such as fluctuations in the forces acting on the wall. By combining these measurements and theoretical analyses, we have developed and calibrated a constitutive model for sliding wear that is a threshold function of granular velocity and stress.

  2. Nanocrystalline diamond thin films on titanium-6 aluminum-4 vanadium alloy temporomandibular joint prosthesis simulants by microwave plasma chemical vapor deposition

    NASA Astrophysics Data System (ADS)

    Fries, Marc Douglas

    A course of research has been performed to assess the suitability of nanocrystal-line diamond (NCD) films on Ti-6Al-4V alloy as wear-resistant coatings in biomedical implant use. A series of temporomandibular (TMJ) joint condyle simulants were polished and acid-passivated as per ASTM F86 standard for surface preparation of implants. A 3-mum-thick coating of NCD film was deposited by microwave plasma chemical vapor deposition (MPCVD) over the hemispherical articulation surfaces of the simulants. Plasma chemistry conditions were measured and monitored by optical emission spectroscopy (OES), using hydrogen as a relative standard. The films consist of diamond grains around 20 nm in diameter embedded in an amorphous carbon matrix, free of any detectable film stress gradient. Hardness averages 65 GPa and modulus measures 600 GPa at a depth of 250 nm into the film surface. A diffuse film/substrate boundary produces a minimal film adhesion toughness (GammaC) of 158 J/m2. The mean RMS roughness is 14.6 +/- 4.2 nm, with an average peak roughness of 82.6 +/- 65.9 nm. Examination of the surface morphology reveals a porous, dendritic surface. Wear testing resulted in two failed condylar coatings out of three tests. No macroscopic delamination was found on any sample, but micron-scale film pieces broke away, exposing the substrate. Electrochemical corrosion testing shows a seven-fold reduction in corrosion rate with the application of an NCD coating as opposed to polished, passivated Ti-6Al-4V, producing a corrosion rate comparable to wrought Co-Cr-Mo. In vivo biocompatibility testing indicates that implanted NCD films did not elicit an immune response in the rabbit model, and osteointegration was apparent for both compact and trabecular bone on both NCD film and bare Ti-6Al-4V. Overall, NCD thin film material is reasonably smooth, biocompatible, and very well adhered. Wear testing indicates that this material is unacceptable for use in demanding TMJ applications without improvements to wear resistance behavior. Identified problems include high surface roughness due to an inadequate seeding procedure and a porous film surface. It is believed that these problems can be solved by future research, in which case NCD thin films should prove to-be well-suited as wear resistant coatings in biomedical applications.

  3. Comparison of wear between occlusal splint materials and resin composite materials.

    PubMed

    Reyes-Sevilla, M; Kuijs, R H; Werner, A; Kleverlaan, C J; Lobbezoo, F

    2018-07-01

    Tooth wear in bruxing patients often results in a need for treatment with composite restorations. In some cases, bruxing patients receive an occlusal splint as a protective means as well. However, the wear between these opposing materials has not been investigated yet. The aim of this in vitro study was to assess the wear of different splint materials against resin composite materials. A two-body wear test was conducted using the ACTA wear machine. The materials selected for this study were three composites used for direct restorations (Filtek Z250, CLEARFIL AP-X, and Filtek Supreme XT) and four occlusal splints materials, viz. a polyamide resin (ThermoSens) an conventional (hand-processed), milled and printed polymethylmethacrylate (PMMA). As antagonistic materials, stainless steel, Filtek Supreme XT and CLEARFIL AP-X were used. The wear rate of the seven materials was determined after 200 000 cycles, using a profilometry. The rates were analysed using two-way ANOVA and post hoc Tukey's tests. The wear rates were significantly higher for the conventional and milled PMMA materials than for all other materials (P < .001). The wear rates of printed PMMA and the polyamide resin were comparable to composite wear rates. The antagonist materials have minor or no influence on the amount of wear of the various splint materials (P < .001). In conclusion, different splint materials yielded different wear rates for all antagonist materials tested. Keeping in mind that this study is an experimental in vitro study, this finding enables practitioners to choose the splint material necessary according to their patients' needs. © 2018 John Wiley & Sons Ltd.

  4. An analysis of contact stiffness between a finger and an object when wearing an air-cushioned glove: the effects of the air pressure.

    PubMed

    Wu, John Z; Wimer, Bryan M; Welcome, Daniel E; Dong, Ren G

    2012-04-01

    Air-cushioned gloves have the advantages of lighter weight, lower cost, and unique mechanical performance, compared to gloves made of conventional engineering materials. The goal of this study is to analyze the contact interaction between fingers and object when wearing an air-cushioned glove. The contact interactions between the the fingertip and air bubbles, which is considered as a cell of a typical air-cushioned glove, has been analyzed theoretically. Two-dimensional finite element models were developed for the analysis. The fingertip model was assumed to be composed of skin layers, subcutaneous tissue, bone, and nail. The air bubbles were modeled as air sealed in the container of nonelastic membrane. We simulated two common scenarios: a fingertip in contact with one single air bubble and with two air cushion bubbles simultaneously. Our simulation results indicated that the internal air pressure can modulate the fingertip-object contact characteristics. The contact stiffness reaches a minimum when the initial air pressure is equal to 1.3 and 1.05 times of the atmosphere pressure for the single air bubble and the double air bubble contact, respectively. Furthermore, the simulation results indicate that the double air bubble contact will result in smaller volumetric tissue strain than the single air bubble contact for the same force. Published by Elsevier Ltd.

  5. Wear behaviors of pure aluminum and extruded aluminum alloy (AA2024-T4) under variable vertical loads and linear speeds

    NASA Astrophysics Data System (ADS)

    Jung, Jeki; Oak, Jeong-Jung; Kim, Yong-Hwan; Cho, Yi Je; Park, Yong Ho

    2017-11-01

    The aim of this study was to investigate the transition of wear behavior for pure aluminum and extruded aluminum alloy 2024-T4 (AA2024-T4). The wear test was carried using a ball-on-disc wear testing machine at various vertical loads and linear speeds. The transition of wear behaviors was analyzed based on the microstructure, wear tracks, wear cross-section, and wear debris. The critical wear rates for each material are occurred at lower linear speed for each vertical load. The transition of wear behavior was observed in which abrasion wears with the generation of an oxide layer, fracture of oxide layer, adhesion wear, severe adhesion wear, and the generation of seizure occurred in sequence. In case of the pure aluminum, the change of wear debris occurred in the order of blocky, flake, and needle-like debris. Cutting chip, flake-like, and coarse flake-like debris was occurred in sequence for the extruded AA2024-T4. The transition in the wear behavior of extruded AA2024-T4 occurred slower than in pure aluminum.

  6. Effect of bionic coupling units' forms on wear resistance of gray cast iron under dry linear reciprocating sliding condition

    NASA Astrophysics Data System (ADS)

    Pang, Zuobo; Zhou, Hong; Xie, Guofeng; Cong, Dalong; Meng, Chao; Ren, Luquan

    2015-07-01

    In order to get close to the wear form of guide rails, the homemade linear reciprocating wear testing machine was used for the wear test. In order to improve the wear-resistance of gray cast iron guide rail, bionic coupling units of different forms were manufactured by a laser. Wear behavior of gray-cast-iron with bionic-coupling units has been studied under dry sliding condition at room temperature using the wear testing machine. The wear resistance was evaluated by means of weight loss measurement and wear morphology. The results indicated that bionic coupling unit could improve the wear resistance of gray cast iron. The wear resistance of gray cast iron with reticulation bionic coupling unit is the best. When the load and speed changed, reticulation bionic coupling unit still has excellent performance in improving the wear resistance of gray cast iron.

  7. The Prevalence of Tooth Wear in the Dutch Adult Population

    PubMed Central

    Wetselaar, Peter; Vermaire, Jan H.; Visscher, Corine M.; Lobbezoo, Frank; Schuller, Annemarie A.

    2016-01-01

    This study aimed to assess the prevalence of tooth wear in different age groups of the Dutch adult population and to determine this tooth wear distribution by gender, socioeconomic class, and type of teeth. Results were compared with the outcomes of a previous study in a comparable population. As part of a comprehensive investigation of the oral health of the general Dutch adult population in 2013, tooth wear was assessed among 1,125 subjects in the city of ‘s-Hertogenbosch. The data collected were subjected to stratified analysis by 5 age groups (25-34, 35-44, 45-54, 55-64, and 65-74 years), gender, socioeconomic class, and type of teeth. Tooth wear was assessed using a 5-point ordinal occlusal/incisal grading scale. The number of teeth affected was higher in older age groups. Men showed more tooth wear than women, and subjects with low socioeconomic status (low SES) showed on average higher scores than those with high SES. Tooth wear prevalence found in this study was higher in all age groups than in the previous study. The present study found prevalences of 13% for mild tooth wear and 80% for moderate tooth wear, leading to the conclusion that these are common conditions in the Dutch adult population. Severe tooth wear (prevalence 6%) may however be characterized as rare. A tendency was found for there to be more tooth wear in older age groups, in men as compared with women, in persons with lower SES, and in the present survey as compared with the previous one. PMID:27694757

  8. The Prevalence of Tooth Wear in the Dutch Adult Population.

    PubMed

    Wetselaar, Peter; Vermaire, Jan H; Visscher, Corine M; Lobbezoo, Frank; Schuller, Annemarie A

    2016-01-01

    This study aimed to assess the prevalence of tooth wear in different age groups of the Dutch adult population and to determine this tooth wear distribution by gender, socioeconomic class, and type of teeth. Results were compared with the outcomes of a previous study in a comparable population. As part of a comprehensive investigation of the oral health of the general Dutch adult population in 2013, tooth wear was assessed among 1,125 subjects in the city of 's-Hertogenbosch. The data collected were subjected to stratified analysis by 5 age groups (25-34, 35-44, 45-54, 55-64, and 65-74 years), gender, socioeconomic class, and type of teeth. Tooth wear was assessed using a 5-point ordinal occlusal/incisal grading scale. The number of teeth affected was higher in older age groups. Men showed more tooth wear than women, and subjects with low socioeconomic status (low SES) showed on average higher scores than those with high SES. Tooth wear prevalence found in this study was higher in all age groups than in the previous study. The present study found prevalences of 13% for mild tooth wear and 80% for moderate tooth wear, leading to the conclusion that these are common conditions in the Dutch adult population. Severe tooth wear (prevalence 6%) may however be characterized as rare. A tendency was found for there to be more tooth wear in older age groups, in men as compared with women, in persons with lower SES, and in the present survey as compared with the previous one. © 2016 S. Karger AG, Basel.

  9. A comparison of different types of hazardous material respirators available to anesthesiologists.

    PubMed

    Candiotti, Keith A; Rodriguez, Yiliam; Shekhter, Ilya; Castillo-Pedraza, Catalina; Rosen, Lisa Forman; Arheart, Kristopher L; Birnbach, David J

    2012-01-01

    Despite anesthesiology personnel involvement in initial treatment of patients exposed to potentially lethal agents, less than 40 percent of US anesthesiology training programs conduct training to manage these patients.(1) No previous studies have evaluated performance of anesthesiologists wearing protective gear. The authors compared the performance of anesthesiologists intubating a high-fidelity mannequin while wearing either a powered air-purifying respirator (PAPR) or a negative pressure respirator (NPR). Twenty participants practiced intubations on a high-fidelity simulator until comfortable. Each subject performed 10 repetitions, initially without any gear, then while wearing a protective suit, gloves, and respirator. The order of gear use was randomized and all subjects used both devices. Time for task completion were recorded, and at the end of the trial, subjects were asked to rate their comfort with the equipment. After controlling for other variables, overall statistically slower total performance times were observed with use of the PAPR when compared to the control arm and use of the NPR (p 5 0.01 and p < 0.007, respectively). Of the total 90 intubations, only one proved to be esophageal and initially undetected. The use of an NPR or PAPR does not preclude an anesthesiologist from successfully intubating, but practice is necessary. The slightly better performance with the NPR is weighed against the improved comfort of the PAPR and the fact that PAPR users could wear eyeglasses. Neither type of gear allowed the users to auscultate the lung fields to confirm correct endotracheal tube placement.

  10. Evidence for the dissolution of molybdenum during tribocorrosion of CoCrMo hip implants in the presence of serum protein.

    PubMed

    Simoes, Thiago A; Bryant, Michael G; Brown, Andy P; Milne, Steven J; Ryan, Mary; Neville, Anne; Brydson, Rik

    2016-11-01

    We have characterized CoCrMo, Metal-on-Metal (MoM) implant, wear debris particles and their dissolution following cycling in a hip simulator, and have related the results to the tribocorrosion of synthetic wear debris produced by milling CoCrMo powders in solutions representative of environments in the human body. Importantly, we have employed a modified ICP-MS sample preparation procedure to measure the release of ions from CoCrMo alloys during wear simulation in different media; this involved use of nano-porous ultrafilters which allowed complete separation of particles from free ions and complexes in solution. As a result, we present a new perspective on the release of metal ions and formation of metal complexes from CoCrMo implants. The new methodology enables the mass balance of ions relative to complexes and particles during tribocorrosion in hip simulators to be determined. A much higher release of molybdenum ions relative to cobalt and chromium has been measured. The molybdenum dissolution was enhanced by the presence of bovine serum albumin (BSA), possibly due to the formation of metal-protein complexes. Overall, we believe that the results could have significant implications for the analysis and interpretation of metal ion levels in fluids extracted from hip arthroplasty patients; we suggest that metal levels, including molybdenum, be analysed in these fluids using the protocol described here. We have developed an important new protocol for the analysis of metal ion levels in fluids extracted from hip implant patients and also hip simulators. Using this procedure, we present a new perspective on the release of metal ions from CoCrMo alloy implants, revealing significantly lower levels of metal ion release during tribocorrosion in hip simulators than previously thought, combined with the release of much higher percentages of molybdenum ions relative to cobalt and chromium. This work is of relevance, both from the perspective of the fundamental science and study of metal-protein interactions, enabling understanding of the ongoing problem associated with the biotribocorrosion and the link to inflammation associated with Metal-on-Metal (MoM) hip implants made from CoCrMo alloys. Copyright © 2016 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  11. Steady-state wear and friction in boundary lubrication studies

    NASA Technical Reports Server (NTRS)

    Loomis, W. R.; Jones, W. R., Jr.

    1980-01-01

    A friction and wear study was made at 20 C to obtain improved reproducibility and reliability in boundary lubrication testing. Ester-base and C-ether-base fluids were used to lubricate a pure iron rider in sliding contact with a rotating M-50 steel disk in a friction and wear apparatus. Conditions included loads of 1/2 and 1 kg and sliding velocities of 3.6 to 18.2 m/min in a dry air atmosphere and stepwise time intervals from 1 to 250 min for wear measurements. The wear rate results were compared with those from previous studies where a single 25 min test period was used. Satisfactory test conditions for studying friction and wear in boundary lubrication for this apparatus were found to be 1 kg load; sliding velocities of 7.1 to 9.1 m/min (50 rpm disk speed); and use of a time stepwise test procedure. Highly reproducible steady-state wear rates and steady-state friction coefficients were determined under boundary conditions. Wear rates and coefficients of friction were constant following initially high values during run-in periods.

  12. X-ray photoelectron spectroscopic study of surface chemistry of dibenzyl-disulfide on steel under mild and severe wear conditions

    NASA Technical Reports Server (NTRS)

    Wheeler, D. R.

    1977-01-01

    Wear tests were performed on 304 stainless steel lubricated with pure mineral oil with and without dibenzyl-disulfide. Both mild and severe wear were observed. The type of wear was distinguished by a marked change in wear rate, friction coefficient, and wear scar appearance. The chemical composition of the wear scar surface was examined with X-ray photoelectron spectroscopy in conjunction with argon ion sputter etching. In severe wear scars, a sulfide was formed at the expense of the normal oxide layer. In mild wear scars, there were only superficial sulfur compounds, but there was a substantial increase in the oxide thickness.

  13. Optimization of pulsed DC PACVD parameters: Toward reducing wear rate of the DLC films

    NASA Astrophysics Data System (ADS)

    Ebrahimi, Mansoureh; Mahboubi, Farzad; Naimi-Jamal, M. Reza

    2016-12-01

    The effect of pulsed direct current (DC) plasma-assisted chemical vapor deposition (PACVD) parameters such as temperature, duty cycle, hydrogen flow, and argon/CH4 flow ratio on the wear behavior and wear durability of the diamond-like carbon (DLC) films was studied by using response surface methodology (RSM). DLC films were deposited on nitrocarburized AISI 4140 steel. Wear rate and wear durability of the DLC films were examined with the pin-on-disk method. Field emission scanning electron microscopy, Raman spectroscopy, and nanoindentation techniques were used for studying wear mechanisms, chemical structure, and hardness of the DLC films. RSM results show that duty cycle is one of the important parameters that affect the wear rate of the DLC samples. The wear rate of the samples deposited with a duty cycle of >75% decreases with an increase in the argon/CH4 ratio. In contrast, for a duty cycle of <65%, the wear rate increases with an increase in the argon/CH4 ratio. The wear durability of the DLC samples increases with an increase in the duty cycle, hydrogen flow, and argon/CH4 flow ratio at the deposition temperature between 85 °C and 110 °C. Oxidation, fatigue, abrasive wear, and graphitization are the wear mechanisms observed on the wear scar of the DLC samples deposited with the optimum deposition conditions.

  14. Wear rate optimization of Al/SiCnp/e-glass fibre hybrid metal matrix composites using Taguchi method and genetic algorithm and development of wear model using artificial neural networks

    NASA Astrophysics Data System (ADS)

    Bongale, Arunkumar M.; Kumar, Satish; Sachit, T. S.; Jadhav, Priya

    2018-03-01

    Studies on wear properties of Aluminium based hybrid nano composite materials, processed through powder metallurgy technique, are reported in the present study. Silicon Carbide nano particles and E-glass fibre are reinforced in pure aluminium matrix to fabricate hybrid nano composite material samples. Pin-on-Disc wear testing equipment is used to evaluate dry sliding wear properties of the composite samples. The tests were conducted following the Taguchi’s Design of Experiments method. Signal-to-Noise ratio analysis and Analysis of Variance are carried out on the test data to find out the influence of test parameters on the wear rate. Scanning Electron Microscopic analysis and Energy Dispersive x-ray analysis are conducted on the worn surfaces to find out the wear mechanisms responsible for wear of the composites. Multiple linear regression analysis and Genetic Algorithm techniques are employed for optimization of wear test parameters to yield minimum wear of the composite samples. Finally, a wear model is built by the application of Artificial Neural Networks to predict the wear rate of the composite material, under different testing conditions. The predicted values of wear rate are found to be very close to the experimental values with a deviation in the range of 0.15% to 8.09%.

  15. The effect of Tricresyl-Phosphate (TCP) as an additive on wear of Iron (Fe)

    NASA Technical Reports Server (NTRS)

    Ghose, Hiren M.; Ferrante, John; Honecy, Frank C.

    1987-01-01

    The effect of tricresyl phosphate (TCP) as an antiwear additive in lubricant trimethyol propane triheptanoate (TMPTH) was investigated. The objective was to examine step loading wear by use of surface analysis, wetting, and chemical bonding changes in the lubricant. The investigation consisted of steploading wear studies by a pin or disk tribometer, the effects on wear related to wetting by contact angle and surface tension measurements of various liquid systems, the chemical bonding changes between lubricant and TCP chromatographic analysis, and by determining the reaction between the TCP and metal surfaces through wear scar analysis by Auger emission spectroscopy (AES). The steploading curve for the base fluid alone shows rapid increase of wear rate with load. The steploading curve for the base fluid in presence of 4.25 percent by volume TCP under dry air purge has shown a great reduction of wear rate with all loads studied. It has also been found that the addition of 4.25 percent by volume TCP plus 0.33 percent by volume water to the base lubricant under N2 purge also greatly reduces the wear rate with all loads studied. AES surface analysis reveals a phosphate type wear resistant film, which greatly increases load-bearing capacity, formed on the iron disk. Preliminary chromatographic studies suggest that this film forms either because of ester oxidation or TCP degradation. Wetting studies show direct correlation between the spreading coefficient and the wear rate.

  16. Study of Abrasive Wear Volume Map for PTFE and PTFE Composites

    NASA Astrophysics Data System (ADS)

    Unal, H.; Sen, U.; Mimaroglu, A.

    2007-11-01

    The potential of this work is based on consideration of wear volume map for the evaluation of abrasive wear performance of polytetrafluoroethylene (PTFE) and PTFE composites. The fillers used in the composite are 25% bronze, 35% graphite and 17% glass fibre glass (GFR). The influence of filler materials, abrasion surface roughness and applied load values on abrasive wear performance of PTFE and PTFE composites were studied and evaluated. Experimental abrasive wear tests were carried out at atmospheric condition on pin-on-disc wear tribometer. Tests were performed under 4, 6, 8 and 10 N load values, travelling speed of 1 m/sec and abrasion surface roughness values of 5, 20 and 45 µm. Wear volume maps were obtained and the results showed that the lowest wear volume rate for PTFE is reached using GFR filler. Furthermore, the results also showed that the higher is the applied load and the roughness of the abrasion surface, the higher is the wear rate. Finally it is also concluded that abrasive wear process mechanism include ploughing and cutting mechanisms.

  17. STS-26 Commander Hauck in fixed based (FB) shuttle mission simulator (SMS)

    NASA Technical Reports Server (NTRS)

    1988-01-01

    STS-26 Discovery, Orbiter Vehicle (OV) 103, Commander Frederick H. Hauck, wearing comunications kit assembly headset, checks control panel data while seated in the commanders seat on forward flight deck. A flight data file (FDF) notebook rests on his lap. A portable computer (laptop) is positioned on the center console. The STS-26 crew is training in the fixed base (FB) shuttle mission simulator (SMS) located in JSC Mission Simulation and Training Facility Bldg 5.

  18. Surface Design and Engineering Toward Wear-Resistant, Self-Lubricating Diamond Films and Coatings

    NASA Technical Reports Server (NTRS)

    Miyoshi, Kazuhisa

    1999-01-01

    The tribological properties of chemical-vapor-deposited (CVD) diamond films vary with the environment, possessing a Jekyll-and-Hyde character. CVD diamond has low coefficient of friction and high wear resistance in air but high coefficient of friction and low wear resistance in vacuum. Improving the tribological functionality of materials (such as achieving low friction and good wear resistance) was an aim of this investigation. Three studies on the surface design, surface engineering, and tribology of CVD diamond have shown that its friction and wear are significantly reduced in ultrahigh vacuum. The main criteria for judging whether diamond films are an effective wear-resistant, self-lubricating material were coefficient of friction and wear rate, which must be less than 0.1 and on the order of 10(exp 6) cu mm/N(dot)m, respectively. In the first study the presence of a thin film (less than 1 micron thick) of amorphous, nondiamond carbon (hydrogenated carbon, also called diamondlike carbon or DLC) on CVD diamond greatly decreased the coefficient of friction and the wear rate. Therefore, a thin DLC film on CVD diamond can be an effective wear-resistant, lubricating coating in ultrahigh vacuum. In the second study the presence of an amorphous, nondiamond carbon surface layer formed on CVD diamond by ion implantation significantly reduced the coefficient of friction and the wear rate in ultrahigh vacuum. Therefore, such surface layers are acceptable for effective self-lubricating, wear-resistant applications of CVD diamond. In the third study CVD diamond in contact with cubic boron nitride exhibited low coefficient of friction in ultra high vacuum. Therefore, this materials combination can provide an effective self-lubricating, wear-resistant couple in ultrahigh vacuum.

  19. EqualWrites: Reducing Intra-set Write Variations for Enhancing Lifetime of Non-volatile Caches

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mittal, Sparsh; Vetter, Jeffrey S.

    Driven by the trends of increasing core-count and bandwidth-wall problem, the size of last level caches (LLCs) has greatly increased and hence, the researchers have explored non-volatile memories (NVMs) which provide high density and consume low-leakage power. Since NVMs have low write-endurance and the existing cache management policies are write variation-unaware, effective wear-leveling techniques are required for achieving reasonable cache lifetimes using NVMs. We present EqualWrites, a technique for mitigating intra-set write variation. In this paper, our technique works by recording the number of writes on a block and changing the cache-block location of a hot data-item to redirect themore » future writes to a cold block to achieve wear-leveling. Simulation experiments have been performed using an x86-64 simulator and benchmarks from SPEC06 and HPC (high-performance computing) field. The results show that for single, dual and quad-core system configurations, EqualWrites improves cache lifetime by 6.31X, 8.74X and 10.54X, respectively. In addition, its implementation overhead is very small and it provides larger improvement in lifetime than three other intra-set wear-leveling techniques and a cache replacement policy.« less

  20. EqualWrites: Reducing Intra-set Write Variations for Enhancing Lifetime of Non-volatile Caches

    DOE PAGES

    Mittal, Sparsh; Vetter, Jeffrey S.

    2015-01-29

    Driven by the trends of increasing core-count and bandwidth-wall problem, the size of last level caches (LLCs) has greatly increased and hence, the researchers have explored non-volatile memories (NVMs) which provide high density and consume low-leakage power. Since NVMs have low write-endurance and the existing cache management policies are write variation-unaware, effective wear-leveling techniques are required for achieving reasonable cache lifetimes using NVMs. We present EqualWrites, a technique for mitigating intra-set write variation. In this paper, our technique works by recording the number of writes on a block and changing the cache-block location of a hot data-item to redirect themore » future writes to a cold block to achieve wear-leveling. Simulation experiments have been performed using an x86-64 simulator and benchmarks from SPEC06 and HPC (high-performance computing) field. The results show that for single, dual and quad-core system configurations, EqualWrites improves cache lifetime by 6.31X, 8.74X and 10.54X, respectively. In addition, its implementation overhead is very small and it provides larger improvement in lifetime than three other intra-set wear-leveling techniques and a cache replacement policy.« less

  1. Wear and microhardness of different resin composite materials.

    PubMed

    Say, Esra Can; Civelek, Arzu; Nobecourt, Alain; Ersoy, Mustafa; Guleryuz, Canan

    2003-01-01

    This study determined the three-body abrasive wear resistance of two packable composites (P-60; Solitaire 2), an ion-releasing composite (Ariston AT), a hybrid composite (Tetric Ceram) and an ormocer (Admira). The study also looked at the correlation between wear resistance and hardness of the composites. Three-body wear testing was performed using an ACTA wear machine with 15 N contact force using millet seed as the third body. Wear depth (microm) was measured by profilometry after 200,000 cycles. The hardness test was performed using a digital microhardness tester (load: 500 g; dwell time: 15 seconds). The data were analyzed by using Kruskal Wallis (p < 0.05). There were statistically significant differences among the three body abrasive wear of the composites. The ranking from least to most were as follows: Filtek P-60 < Solitaire 2 < Ariston AT < Tetric Ceram < Admira. Filtek P-60 showed the highest microhardness value. No other significant differences in hardness were observed among the different resin composites (P-60 > AristonAT = Tetric Ceram = Solitaire 2 = Admira). The results of this study indicate that there are significant differences in the wear resistance of the resin composites. The correlation between hardness and wear was significant with a correlation coefficient of r:-0.91. A significant negative correlation exists between hardness and three-body wear of resin composites.

  2. STS-26 MS Lounge floats in life raft during JSC WETF exercises

    NASA Technical Reports Server (NTRS)

    1988-01-01

    STS-26 Discovery, Orbiter Vehicle (OV) 103, Mission Specialist (MS) John M. Lounge, wearing the newly designed launch and entry suit (LES), floats in single-occupant life raft in JSC Weightless Environment Training Facility (WETF) Bldg 29 pool. Lounge pulls cord on life raft and enlists the aid of a SCUBA-equipped diver. The simulation of the escape and rescue operations utilized the crew escape system (CES) pole method of egress from the Space Shuttle. Lounge is wearing gear like that each STS-26 crewmember and subsequent crews will carry onboard during launch.

  3. A New Tribological Test for Candidate Brush Seal Materials Evaluation

    NASA Technical Reports Server (NTRS)

    Fellenstein, James A.; Dellacorte, Christopher

    1994-01-01

    A new tribological test for candidate brush seal materials evaluation has been developed. The sliding contact between the brush seal wires and their mating counterface journal is simulated by testing a small tuft of wire against the outside diameter of a high speed rotating shaft. The test configuration is similar to a standard block on ring geometry. The new tester provides the capability to measure both the friction and wear of candidate wire and counterface materials under controlled loading conditions in the gram to kilogram range. A wide test condition latitude of speeds (1 to 27 m/s), temperatures (25 to 700 C), and loads (0.5 to 10 N) enables the simulation of many of the important tribological parameters found in turbine engine brush seals. This paper describes the new test rig and specimen configuration and presents initial data for candidate seal materials comparing tuft test results and wear surface morphology to field tested seal components.

  4. Computational homogenisation for thermoviscoplasticity: application to thermally sprayed coatings

    NASA Astrophysics Data System (ADS)

    Berthelsen, Rolf; Denzer, Ralf; Oppermann, Philip; Menzel, Andreas

    2017-11-01

    Metal forming processes require wear-resistant tool surfaces in order to ensure a long life cycle of the expensive tools together with a constant high quality of the produced components. Thermal spraying is a relatively widely applied coating technique for the deposit of wear protection coatings. During these coating processes, heterogeneous coatings are deployed at high temperatures followed by quenching where residual stresses occur which strongly influence the performance of the coated tools. The objective of this article is to discuss and apply a thermo-mechanically coupled simulation framework which captures the heterogeneity of the deposited coating material. Therefore, a two-scale finite element framework for the solution of nonlinear thermo-mechanically coupled problems is elaborated and applied to the simulation of thermoviscoplastic material behaviour including nonlinear thermal softening in a geometrically linearised setting. The finite element framework and material model is demonstrated by means of numerical examples.

  5. Application to recognition of ferrography image with fractal neural network

    NASA Astrophysics Data System (ADS)

    Tian, Xianzhong; Hu, Tongsen; Zhang, Jian

    2005-10-01

    Because wear particles have fractal characteristics, it is necessary that adding fractal parameters to studying wear particles and diagnosing machine troubles. This paper discusses fractal parameters of wear particles, presents arithmetic calculating fractal dimension, and constructs a fractal neural network which can recognize wear particles image. It is proved by experiments that this fractal neural network can recognize some characteristics of wear particles image, and can also classify wear types.

  6. Hollow Cathode Assembly Development for the HERMeS Hall Thruster

    NASA Technical Reports Server (NTRS)

    Sarver-Verhey, Timothy R.; Kamhawi, Hani; Goebel, Dan M.; Polk, James E.; Peterson, Peter Y.; Robinson, Dale A.

    2016-01-01

    To support the operation of the HERMeS 12.5 kW Hall Thruster for NASA's Asteroid Redirect Robotic Mission, hollow cathodes using emitters based on barium oxide impregnate and lanthanum hexaboride are being evaluated through wear-testing, performance characterization, plasma modeling, and assessment of system implementation concerns. This paper will present the development approach used to assess the cathode emitter options. A 2,000-hour wear-test of development model barium-oxide-based (BaO) hollow cathode is being performed as part of the development plan. The cathode was operated with an anode that simulates the HERMeS hall thruster operating environment. Cathode discharge performance has been stable with the device accumulating 740 hours at the time of this report. Cathode operation (i.e. discharge voltage and orifice temperature) was repeatable during period variation of discharge current and flow rate. The details of the cathode assembly operation during the wear-test will be presented.

  7. Cornering and wear behavior of the Space Shuttle Orbiter main gear tire

    NASA Technical Reports Server (NTRS)

    Daugherty, Robert H.; Stubbs, Sandy M.

    1987-01-01

    One of the factors needed to describe the handling characteristics of the Space Shuttle Orbiter during the landing rollout is the response of the vehicle's tires to variations in load and yaw angle. An experimental investigation of the cornering characteristics of the Orbiter main gear tires was conducted at the NASA Langley Research Center Aircraft Landing Dynamics Facility. This investigation compliments earlier work done to define the Orbiter nose tire cornering characteristics. In the investigation, the effects of load and yaw angle were evaluated by measuring parameters such as side load and drag load, and obtaining measurements of aligning torque. Because the tire must operate on an extremely rough runway at the Shuttle Landing Facility at Kennedy Space Center (KSC), tests were also conducted to describe the wear behavior of the tire under various conditions on a simulated KSC runway surface. Mathematical models for both the cornering and the wear behavior are discussed.

  8. Influence of water-miscible cutting fluid on tool wear behavior of various coated high-speed steel tools in hobbing

    NASA Astrophysics Data System (ADS)

    Sato, Yuta; Matsuoka, Hironori; Kubo, Akio; Ono, Hajime; Ryu, Takahiro; Qiu, Hua; Nakae, Takashi; Shuto, Shuichi; Watanabe, Suguru; Anan, Ruito

    2017-04-01

    This paper deals with the influence of water-miscible cutting fluid on tool life (flank wear) compared with that with dry cutting and water-insoluble cutting oil in hobbing. Experiments were conducted by simulating hobbing by fly tool cutting on a milling machine. The following results were clarified. (1) The water-miscible cutting fluid used in the test prolongs the tool life for TiN-, TiAlN-, TiSiN- and AlCrSiN-coated tools in comparison with that obtained by dry cutting and water-insoluble cutting oil. (2) It was presumed that the tool wear decreases and the tool life is improved by the lubrication effect of the synthetic lubrication additive, mineral oil and sulfuric EP additive contained in the water-miscible cutting fluid, and also by the cooling effect.

  9. Tribology Study of High-Technological Composite Coatings Applied Using High Velocity Oxy-Fuel

    NASA Astrophysics Data System (ADS)

    Kandeva, M.; Grozdanova, T.; Karastoyanov, D.; Ivanov, Pl; Kalichin, Zh

    2018-01-01

    In the work are studied the differential parameters of wear and wear resistance of high-tech composite coatings of powder superalloys with nickel matrix, WC-12Co and mixed compositions. Coatings were created and applied to a substrate of steel with a different flame velocity - 700 m/s and 1000 m/s without preheating the substrate and with preheating the substrate to 650° C. The wear is carried out with a "thumb-disk" tribotester under dry surface friction with fixed black corundum abrasive particles. Comparative results were obtained for the microstructure and texture of the pre- and post- friction coating, the porosity, roughness, hardness, the dependence of mass wear, the speed and wear intensity and the wear resistance of the coatings on the number of friction cycles. Influence of the flame rate and substrate temperature on wear resistance and differential wear parameters has been determined.

  10. Dynamic SEM wear studies of tungsten carbide cermets

    NASA Technical Reports Server (NTRS)

    Brainard, W. A.; Buckley, D. H.

    1975-01-01

    Dynamic friction and wear experiments were conducted in a scanning electron microscope. The wear behavior of pure tungsten carbide and composite with 6 and 15 weight percent cobalt binder was examined. Etching of the binder was done to selectively determine the role of the binder in the wear process. Dynamic experiments were conducted as the WC and bonded WC cermet surfaces were transversed by a 50 micron radiused diamond stylus. These studies show that the predominant wear process in WC is fracture initiated by plastic deformation. The wear of the etched cermets is similar to pure WC. The presence of the cobalt binder reduces both friction and wear. The cementing action of the cobalt reduces granular separation and promotes a dense polished layer because of its low shear strength film-forming properties. The wear debris generated from unetched surface is approximately the same composition as the bulk.

  11. Ten-year in vivo wear measurement of a fully congruent mobile bearing unicompartmental knee arthroplasty.

    PubMed

    Price, A J; Short, A; Kellett, C; Beard, D; Gill, H; Pandit, H; Dodd, C A F; Murray, D W

    2005-11-01

    Polyethylene particulate wear debris continues to be implicated in the aetiology of aseptic loosening following knee arthroplasty. The Oxford unicompartmental knee arthroplasty employs a spherical femoral component and a fully congruous meniscal bearing to increase contact area and theoretically reduce the potential for polyethylene wear. This study measures the in vivo ten-year linear wear of the device, using a roentgenstereophotogrammetric technique. In this in vivo study, seven medial Oxford unicompartmental prostheses, which had been implanted ten years previously were studied. Stereo pairs of radiographs were acquired for each patient and the films were analysed using a roentgen stereophotogrammetric analysis calibration and a computer-aided design model silhouette-fitting technique. Penetration of the femoral component into the original volume of the bearing was our estimate of linear wear. In addition, eight control patients were examined less than three weeks post-insertion of an Oxford prosthesis, where no wear would be expected. The control group showed no measured wear and suggested a system accuracy of 0.1 mm. At ten years, the mean linear wear rate was 0.02 mm/year. The results from this in vivo study confirm that the device has low ten-year linear wear in clinical practice. This may offer the device a survival advantage in the long term.

  12. Personal, social, and environmental factors associated with lifejacket wear in adults and children: A systematic literature review

    PubMed Central

    Demant, Daniel; Hagger, Martin S.; Hamilton, Kyra

    2018-01-01

    Objective Drowning claims 7% of the global burden of injury-related deaths. Lifejackets are routinely recommended as a drowning prevention strategy; however, a review of related factors regarding lifejacket wear has not previously been investigated. Methods This systematic review examined literature published from inception to December 2016 in English and German languages. The personal, social, and environmental factors associated with lifejacket wear among adults and children were investigated, a quantitative evaluation of the results undertaken, and gaps in the literature identified. Results Twenty studies, with sample sizes of studies ranging between 20 and 482,331, were identified. Fifty-five percent were cross-sectional studies. All studies were scored IV or V on the Australian National Health and Medical Research Council (NHMRC) grading system indicating mostly descriptive and cross-sectional levels of evidence. Factors associated with increased wear included age (mostly children), gender (mostly female), boat type (non-motorised), boat size (small boats), role modelling (children influenced by adult lifejacket wear), and activity (water-skiing, fishing). Factors not associated or inconsistent with lifejacket wear included education, household income, ethnicity, boating ability, confidence in lifejackets, waterway type, and weather and water conditions. Factors associated with reduced lifejacket wear included adults, males, discomfort, cost and accessibility, consumption of alcohol, and swimming ability. Three studies evaluated the impact of interventions. Conclusion This review identified factors associated with both increased and decreased lifejacket wear. Future research should address the motivational factors associated with individuals’ decisions to wear or not wear lifejackets. This, combined with further research on the evaluation of interventions designed to increase lifejacket wear, will enhance the evidence base to support future drowning prevention interventions. PMID:29718971

  13. Tooth wear in the elderly population in South East Local Government area in Ibadan, Nigeria.

    PubMed

    Taiwo, J O; Ogunyinka, A; Onyeaso, C O; Dosumu, O O

    2005-12-01

    It is the aim of this study to determine the pattern and degree of tooth wear in the elderly population in the South East Local Government Area in Ibadan. The study was carried out on 690 elderly individuals who were 65 years old and above, living in various wards in South East Local Government Area, in Ibadan. A multistage sampling technique was used to select elderly individuals for the study. Two interviewers, 2-record clerks and 2 examiners were trained for the study and the examiners were calibrated. The index of Eccles J.D was used to determine the severity of tooth wear. The results highlight the high prevalence of tooth wear, mainly attrition in the elderly in this local government area. Six hundred and forty (92.8%) of the elderly had tooth wear. Of these 58.59% were males and 41.41% females. Attrition was observed in 618 (89.6%) elderly individuals. The mandible exhibited a higher prevalence of tooth wear than the maxilla and was statistically significant. Severe tooth wear was observed in only 5.74% of the teeth whilst moderate and mild tooth wear were observed in 26.91% and 30.88% respectively. Unlike the Western European countries, attrition being the most common type of tooth wear in these elderly individuals suggests that the aetiological factors responsible for tooth wear are different. Common habits such as crushing of bones and chewing of sticks for routine oral hygiene care could be contributing factors to tooth wear in this environment.

  14. In-volume structuring of a bilayered polymer foil using direct laser interference patterning

    NASA Astrophysics Data System (ADS)

    Rößler, Florian; Günther, Katja; Lasagni, Andrés F.

    2018-05-01

    Periodic surface patterns can provide materials with special optical properties, which are usable in decorative or security applications. However, they can be sensitive to contact wear and thus their lifetime and functionality are limited. This study describes the use of direct laser interference patterning for structuring a multilayered polymer film at its interface creating periodic in-volume structures which are resistant to contact wear. The spatial period of the structures are varied in the range of 1.0 μm to 2.0 μm in order to produce decorative elements. The pattern formation at the interface is explained using cross sectional observations and a thermal simulation of the temperature evolution during the laser treatment at the interface. Both, the diffraction efficiency and direct transmission are characterized by light intensity measurements to describe the optical behavior of the produced periodic structures and a decorative application example is presented.

  15. Reciprocating sliding wear evaluation of a polymeric/coating tribological system

    NASA Astrophysics Data System (ADS)

    Braza, J. F.; Furst, R. E.

    1993-04-01

    Reciprocating screening tests aimed at simulating a control bearing in a contaminated environment to discern the optimum polymeric/coating combination are described. The polymeric/coating systems were compared with the wear of a baseline phenolic impregnated polytetrafluoroethylene (PTFE) polyester woven fabric composite against an uncoated stainless steel substrate. The polymeric composites under consideration include a polyamide-imide (PAI), a polybenzimidazole, and an injection-moldable PEEK. Results indicate that the system of either PEEK or PAI with an E-Ni-PTFE- or TiN-coated substrate produced the best tribological system. These two composites also exhibited a significant improvement over the baseline fabric when tested against the high-velocity oxygen-fuel thermal spray coating. To discern better the optimum polymeric composite/coating system, full-scale testing must be conducted to study system dynamics, vibrations, counterface hardness and roughness, temperature, external environment and application specific conditions.

  16. The use of analytical surface tools in the fundamental study of wear. [atomic nature of wear

    NASA Technical Reports Server (NTRS)

    Buckley, D. H.

    1977-01-01

    Various techniques and surface tools available for the study of the atomic nature of the wear of materials are reviewed These include chemical etching, x-ray diffraction, electron diffraction, scanning electron microscopy, low-energy electron diffraction, Auger emission spectroscopy analysis, electron spectroscopy for chemical analysis, field ion microscopy, and the atom probe. Properties of the surface and wear surface regions which affect wear, such as surface energy, crystal structure, crystallographic orientation, mode of dislocation behavior, and cohesive binding, are discussed. A number of mechanisms involved in the generation of wear particles are identified with the aid of the aforementioned tools.

  17. [Comparison of in vivo characteristics of polyethylene wear particles produced by a metal and a ceramic femoral component in total knee replacement].

    PubMed

    Veigl, D; Vavřík, P; Pokorný, D; Slouf, M; Pavlova, E; Landor, I

    2011-01-01

    The aim of the study was to evaluate in vivo and compare, in terms of the quality and number of ultra high-molecular polyethylene (UHMWPE) wear particles, total knee replacements of identical construction differing only in the material used for femoral component production, i.e., CoCrMo alloy or ZrO2 ceramics. Samples of peri-prosthetic granuloma tissue were collected in two patients with total knee replacement suffering from implant migration, who were matched in relevant characteristics. The primary knee replacement in Patient 1 with a CoCrMo femoral component was done 7.2 years and in Patient 2 with a ZrO2 implant 6.8 years before this assessment. The polyethylene wear-induced granuloma was analysed by the MORF method enabling us to assess the shape and size of wear debris and the IRc method for assessment of particle concentration. In the granuloma tissue samples of Patient 1, on the average, particles were 0.30 mm in size and their relative volume was 0.19. In the Patient 2 tissue samples, the average size of particles was 0.33 mm and their relative volume was 0.26. There was no significant difference in either particle morphology or their concentration in the granuloma tissue between the two patients. One of the options of how to reduce the production of polyethylene wear particles is to improve the tribological properties of contacting surfaces in total knee replacement by substituting a cobalt-chrome femoral component with a zirconia ceramic femoral component. The previous in vitro testing carried out with a mechanical simulator under conditions approaching real weight-bearing in the human body did show a nearly three-fold decrease in the number of UHMWPE wear particles in zirconia components. The evaluation of granuloma tissue induced by the activity of a real prosthetic joint for nearly seven years, however, did not reveal any great difference in either quality or quantity of polyethylene debris between the two replacements. The difference of surface roughness between CoCrMo (Ra = 0.05) and ZrO2 (Ra = 0.02) components did not play any role in in vivo conditions. CONCLUSIONS In accordance with a previous clinical study, this evaluation of the quality and quantity of UHMWPE wear particles produced by a ceramic femoral component in vivo failed to demonstrate any advantage of zirconia ceramic components over the cobalt-chrome femoral components so far used.

  18. Sliding wear and friction behaviour of zircaloy-4 in water

    NASA Astrophysics Data System (ADS)

    Sharma, Garima; Limaye, P. K.; Jadhav, D. T.

    2009-11-01

    In water cooled nuclear reactors, the sliding of fuel bundles in fuel channel handling system can lead to severe wear and it is an important topic to study. In the present study, sliding wear behaviour of zircaloy-4 was investigated in water (pH ˜ 10.5) using ball-on-plate sliding wear tester. Sliding wear resistance zircaloy-4 against SS 316 was examined at room temperature. Sliding wear tests were carried out at different load and sliding frequencies. The coefficient of friction of zircaloy-4 was also measured during each tests and it was found to decrease slightly with the increase in applied load. The micro-mechanisms responsible for wear in zircaloy-4 were identified to be microcutting, micropitting and microcracking of deformed subsurface zones in water.

  19. A study of the wear behaviour of ion implanted pure iron

    NASA Astrophysics Data System (ADS)

    Goode, P. D.; Peacock, A. T.; Asher, J.

    1983-05-01

    The technique of Thin Layer Activation (TLA) has been used to monitor disc wear in pin-on-disc wear tests. By simultaneously monitoring the pin wear the relationship between the wear rates of the two components of the wear couple has been studied. Tests were carried out using untreated pins wearing against ion implanted and untreated pure iron discs. The ratio of pin/disc volumetric wear rates was found to be constant in tests with unimplanted discs. In the implanted case the ratio was 8 initially, rising to the unimplatned value of 24 by a sliding distance of 25 km. The relationship between pin and disc wear after nitrogen implantation of the disc was approximately independent of dose between values of 7×10 16 and 1.2×10 18 N atoms cm -2. The actual wear rates of both pin and disc were significantly lower after implantation with the greater effects being observed om the unimplanted pin. The effects are explained in terms of the model of oxidative wear. In the unimplanted case the high pin wear relative to disc wear is considered to result from the higher mean temperature of pin asperities. Implantation appears to alter the mean asperity temperatures in such a way as to reduce the oxidation rate of the pin preferentially. Alternatively the effect of the implantation could be to reduce the critical thickness for removal of oxide formed on disc asperities.

  20. In vitro wear of new indirect resin composites.

    PubMed

    Jain, V; Platt, J A; Moore, B K; Borges, G A

    2009-01-01

    This in vitro study evaluated the toothbrush abrasion wear, three-body Alabama wear and two-body pin-on-disc wear of four commercial indirect resin composites. Enamel shades of Radica (R), Sculpture Plus (S), Belleglass-NG (B) and Gradia Indirect (G) were used. For measuring wear due to toothbrush abrasion, six specimens of each group were fabricated, then brushed in a toothbrush abrasion machine for 20,000 cycles. Material loss was determined by weighing and conversion to volume loss. Three-body wear was measured on six samples for each group using an Alabama-type wear testing machine for 400,000 cycles. Wear depth was measured with a contact profilometer. For two-body wear, five disc specimens were prepared and tested in a two-body wear-testing machine against hydroxypatite sliders for 25,000 cycles. Data were analyzed with one-way analysis of variance (ANOVA) and Tukey test (alpha=0.05). Wear was the highest in Sculpture Plus by all three methods tested and the lowest wear was observed in Belleglass-NG. No statistical difference in wear was noted from Radica.

  1. A comparative study of progressive wear of four dental monolithic, veneered glass-ceramics.

    PubMed

    Zhang, Zhenzhen; Yi, Yuanping; Wang, Xuesong; Guo, Jiawen; Li, Ding; He, Lin; Zhang, Shaofeng

    2017-10-01

    This study evaluated the wear performance and wear mechanisms of four dental glass-ceramics, based on the microstructure and mechanical properties in the progressive wear process. Bar (N = 40, n = 10) and disk (N = 32, n = 8) specimens were prepared from (A) lithium disilicate glass-ceramic (LD), (B) leucite reinforced glass-ceramic (LEU), (C) feldspathic glass-ceramic (FEL), and (D) fluorapatite glass-ceramic (FLU). The bar specimens were tested for three-point flexural strength, hardness, fracture toughness and elastic modulus. The disk specimens paired with steatite antagonists were tested in a pin-on-disk tribometer with 10N up to 1000,000 wear cycles. The wear analysis of glass-ceramics was performed using a 3D profilometer after every 200,000 wear cycles. Wear loss of steatite antagonists was calculated by measuring the weight and density using sensitive balance and Archimedes' method. Wear morphologies and microstructures were analyzed by scanning electron microscopy (SEM). The crystalline phase compositions were determined using X-ray diffraction (XRD). One-way analysis of variance (ANOVA) was used to analyze the data. Multiple pair-wise comparison of means was performed by Tukey's post-hoc test. LD showed the highest fracture toughness, flexural strength, elastic modulus and crystallinity, followed by LEU and FEL, and FLU showed the lowest. However, the hardness of LD was lower than all the other three types of ceramics. For steatite antagonists, LD produced the least wear loss of antagonist, followed by LEU and FEL, and FLU had the most wear loss. For glass-ceramic materials, LD exhibited similar wear loss as LEU, but more than FLU and FEL did. Moreover, fracture occurred on the wear surface of FLU. In the progressive wear process, veneering porcelains showed better wear resistance but fluorapatite veneering porcelains appeared fracture surface. Monolithic lithium disilicate glass-ceramics with higher mechanical properties showed more wear loss, however, they did not fracture and produced less wear loss of antagonists. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Tibial interface wear in retrieved total knee components and correlations with modular insert motion.

    PubMed

    Rao, Anand R; Engh, Gerard A; Collier, Matthew B; Lounici, Smain

    2002-10-01

    Wear occurring at the interface between the polyethylene insert and metal baseplate of a modular tibial component has become an increasingly common finding at the time of revision total knee arthroplasty. Although this so-called backside wear on retrieved polyethylene inserts has been evaluated in prior studies, wear on retrieved metal baseplates has not been described, to our knowledge. The purposes of the present study were to characterize backside wear on retrieved polyethylene inserts and on the mating surfaces of their corresponding baseplates and to investigate if there is a relationship between backside wear and relative motion of the modular elements. Twenty-nine retrieved modular tibial components of twelve fixed-bearing designs were analyzed in vitro with regard to backside wear and relative motion between the polyethylene insert and the metal baseplate. We graded the backside of each polyethylene insert and the mating surface of the metal baseplate for wear with use of a scoring system that consisted of three modes of wear and three levels of severity of wear. Relative motion between the insert and the baseplate was measured in the transverse plane with use of a mechanical testing machine. These measurements were used to compute the insert motion index, which served to quantify unrestricted motion of the insert with respect to the baseplate. The mean insert motion index for the tibial components was 416 micro m (range, 104 micro m to 760 micro m). On a wear-grading scale ranging from 0 to 54 (with 0 indicating no wear), the mean backside wear score was 30 (range, 12 to 48) for the inserts and 28 (range, 7 to 51) for the baseplates. Insert motion was positively correlated with backside polyethylene wear (p = 0.003) and baseplate wear (p < 0.001). Baseplate wear was strongly correlated with backside polyethylene wear (p < 0.001). Backside wear was correlated with the relative motion between the polyethylene insert and the metal baseplate. New locking mechanism designs directed toward better methods of securing the polyethylene insert to the tibial tray are needed to minimize the generation of particulate wear debris at the modular interface.

  3. Astronaut Neil Armstrong during thermovacuum training

    NASA Image and Video Library

    1969-05-07

    Astronaut Neil A. Armstrong, commander of the Apollo 11 lunar landing mission, is photographed during thermovacuum training in Chamber B of the Space Environment Simulation Laboratory, Building 32, Manned Spacecraft Center. He is wearing an Extravehicular Mobility Unit. The training simulated lunar surface vacuum and thermal conditions during astronaut operations outside the Lunar Module on the moon's surface. The mirror was used to reflect solar light.

  4. STS-26 Pilot Covey floats in life raft during JSC WETF exercises

    NASA Technical Reports Server (NTRS)

    1988-01-01

    STS-26 Discovery, Orbiter Vehicle (OV) 103, Pilot Richard O. Covey, wearing newly designed launch and entry suit (LES), floats in single-occupant life raft during simulations in the JSC Weightless Environment Training Facility Bldg 29 pool. During the simulation of escape and rescue operations, the crew escape system (CES) pole mode of egress from the Space Shuttle was utilized.

  5. Acceleration endurance with pressure breathing during G with and without a counterpressure vest.

    PubMed

    Walker, Thomas B; Dart, Todd; Morgan, Thomas R; Balldin, Ulf I

    2014-04-01

    The purpose of this study was to test whether pressure breathing during G (PBC) without a counterpressure vest negatively influences G endurance or increases breathing fatigue during extended duration high-G exposures. While using PBG, 10 subjects underwent 2 trials of +3 Gz exposures: once when wearing a counterpressure vest and once without. The exposures consisted of a relaxed, gradual G onset run until peripheral or central light loss, a straining rapid onset GC run to +6 Gz for 15 s, and a simulated aerial combat maneuver (SACM) G profile consisting of 10-s periods varying between +5 Gz and +9 Gz, during which subjects executed a hand-eye tracking task. The SACM endpoint was light loss or exhaustion. Subjects provided ratings of subjective effort and discomfort after the SACM. Significant differences were found between the vest and no-vest conditions for only 3 of 19 measures: heart rate under G and two measures of tracking ability. The vast majority of data indicated no difference between the vest and no-vest conditions for performance under G. This experiment supports previous studies and expands those previous results by increasing the duration of PBG exposure shown to not be influenced by wearing of the vest. We conclude that there is likely no practical advantage to wearing a counterpressure vest during PBG.

  6. Hybrid Nanoparticles as Oil Lubricant Additives for Friction and Wear Reduction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhao, Bin; Dai, Sheng; Qu, Jun

    A new class of organic-inorganic/metallic hybrid nanoparticles (NPs), including oil-soluble polymer brush-grafted metal oxide NPs and organic-modified metallic NPs, was developed and used as oil lubricant additives for friction and wear reduction to improve engine energy efficiency. The tribological properties of these hybrid NPs in polyalphaolefin (PAO) base oil were investigated by high contact stress ball-on-flat reciprocating sliding tribological tests at 100 oC. Using surface-initiated “living”/controlled radical polymerization from initiator- or chain transfer agent-functionalized metal oxide (silica and titania) NPs, we synthesized a series of hairy NPs and systematically studied the effects of molecular weight and chemical composition of graftedmore » polymer brushes on oil dispersibility, stability, and lubrication properties of hairy NPs in PAO. In addition, several types of organic-modified metallic NPs, including silver and palladium NPs, were synthesized by using thiol compounds and ionic liquids (ILs) as ligands. Significant reductions in friction (up to 40%) and wear volume (up to 90%) were achieved by using PAO mixed with hairy NPs or organic-modified metal NPs compared to PAO base oil. Moreover, a positive effect on lubricating performance was observed when oil-soluble hairy silica NPs and an IL were used simultaneously as additives for PAO for friction reduction. The lubrication mechanisms of these hybrid NPs were elucidated by both experimental and simulation studies.« less

  7. Effect of Interviewer's Eyeglasses on Compliance with a Face-to-Face Survey Request and Perception of the Interviewer

    ERIC Educational Resources Information Center

    Guéguen, Nicolas; Martin, Angélique

    2017-01-01

    Several studies have shown that people photographed wearing eyeglasses were perceived more positively as to intelligence and honesty. However, the effect of wearing glasses on behavior and in real face-to-face relationships has never been examined. In two studies, interviewers wearing or not wearing eyeglasses were instructed to ask people in the…

  8. Advanced Clothing Studies

    NASA Technical Reports Server (NTRS)

    Orndoff, Evelyne; Poritz, Darwin

    2014-01-01

    All human space missions require significant logistical mass and volume that add an unprecedented burden on longduration missions beyond low-Earth orbit. For these missions with limited cleaning resources, a new wardrobe must be developed to reduce this logistical burden by reducing clothing mass and extending clothing wear. The present studies have been undertaken, for the first time, to measure length of wear and to assess the acceptance of such extended wear. Garments in these studies are commercially available exercise T-shirts and shorts, routine-wear T-shirts, and longsleeved pullover shirts. Fabric composition (cotton, polyester, light-weight, superfine Merino wool, modacrylic, cotton/rayon, polyester/Cocona, modacrylic/Xstatic, modacrylic/rayon, modacrylic/lyocell/aramid), construction (open knit, tight knit, open weave, tight weave), and finishing treatment (none, quaternary ammonium salt) are the independent variables. Eleven studies are reported here: five studies of exercise T-shirts, three of exercise shorts, two of routine wear Tshirts, and one of shirts used as sleep-wear. All studies are conducted in a climate-controlled environment, similar to a space vehicle's. For exercise clothing, study participants wear the garments during aerobic exercise. For routine wear clothing, study participants wear the T-shirts daily in an office or laboratory. Daily questionnaires collected data on ordinal preferences of nine sensory elements and on reason for retiring a used garment. Study 1 compares knitted cotton, polyester, and Merino exercise T-shirts (61 participants), study 2, knitted polyester, modacrylic, and polyester/Cocona exercise T-shirts (40 participants), study 3, cotton and polyester exercise shorts, knitted and woven (70 participants), all three using factorial experimental designs with and without a finishing treatment, conducted at the Johnson Space Center, sharing study participants. Study 4 compares knitted polyester and ZQ Merino exercise T-shirts, study 5, knitted ZQ Merino and modacrylic routine-wear T-shirts, with study 6 using only knitted polyester exercise shorts. No finishing treatment is used. Studies 4 and 5 use cross-over experimental designs, and all three studies were conducted aboard the ISS with six crew. Studies 4 and 6 were repeated on the ground with the same participants to learn if perception was affected microgravity. Study 7 is a longer-term, single-blind panel study of knitted routine-wear undershirts with at least 12 participants to assess tolerance to Merino by comparing it with a cotton/rayon blends, using a cross-over design, eliminating carryover effects with wash-out periods between shirts.

  9. Wear characteristics of bonded solid film lubricant under high load condition

    NASA Technical Reports Server (NTRS)

    Hiraoka, Naofumi; Sasaki, Akira; Kawashima, Noritsugu; Honda, Toshio

    1991-01-01

    Wear properties of phenolic resin bonded molybdenum disulfide film lubricant were studied. In-vacuo journal bearing tests were performed to evaluate the wear-life of this film lubricant. The wear-life depends on substrate materials and on sliding velocity. Pretreated substrate surfaces were examined to reveal the reasons for these results. Additionally, investigations on film wear mechanisms were made.

  10. Detailed study of oxidation/wear mechanism in lox turbopump bearings

    NASA Technical Reports Server (NTRS)

    Chase, T. J.; Mccarty, J. P.

    1993-01-01

    Wear of 440C angular contact ball bearings of the phase 2 high pressure oxygen turbopump (HPOTP) of the space shuttle main engine (SSME) has been studied by means of various advanced nondestructive techniques (NDT) and modeled with reference to all known material, design, and operation variables. Three modes dominating the wear scenario were found to be the adhesive/sheer peeling (ASP), oxidation, and abrasion. Bearing wear was modeled in terms of the three modes. Lacking a comprehensive theory of rolling contact wear to date, each mode is modeled after well-established theories of sliding wear, while sliding velocity and distance are related to microsliding in ball-to-ring contacts. Microsliding, stress, temperature, and other contact variables are evaluated with analytical software packages of SHABERTH(TM)/SINDA(TM) and ADORE(TM). Empirical constants for the models are derived from NIST experiments by applying the models to the NIST wear data. The bearing wear model so established precisely predicts quite well the average ball wear rate for the HPOTP bearings. The wear rate has been statistically determined for the entire population of flight and development bearings based on Rocketdyne records to date. Numerous illustrations are given.

  11. The production and tribology of hard facing coatings for agricultural applications

    NASA Astrophysics Data System (ADS)

    Roffey, Paul

    Abrasive wear is a significant issue in many industries but is of particular significance in agriculture. This research is being carried out due to the demand for a hard wearing, economical coating for use in the agricultural industry.A primary objective has been to review and develop an in depth understanding of the type of wear suffered by metal shares in agricultural soils. The affect of soil properties and abrasive wear environments on the amount of wear that occurs, and the way in which material properties can be used to reduce or prevent this has also been investigated. A review of the diverse range of soil properties, such as the mineral content, moisture content, soils strengths has been carried out in order to create an appropriate wear test procedure.The coatings developed for testing were modifications to an existing powder metallurgy coating. The modifications were made by the addition of selected hard phases to the powder prior to sintering. The resulting materials were characterised in terms of sinterability, hardness and abrasive wear resistance. Prior to commencing this work little or no data existed on the wear performance of the pre-existing coating. Wear resistance has been measured using a fixed ball micro-scale abrasive wear test (also known as the ball-cratering wear test) with SiC and SiO2 abrasives and also using a modified version of the ASTM G65 abrasive wear test which allowed testing in dry and wet modes. Limited field trials were performed to determine the abrasive wear resistance in real soil. Results from wear testing have determined that the optimum modification to the coating can improve performance compared to the unmodified coating.Detailed scanning electron microscopy (SEM) has been performed on the wear scars and has revealed the resultant wear mechanisms and role that the hard phase additions play in improving the wear resistance. The influence of the hard phase addition on the microstructure has also been studied.The wear volume and corresponding wear coefficient from laboratory studies have been used to determine the optimum level of addition that can be added to produce an improved wear resistance. The results show the optimum hard phase addition to be 100mum WC/W[2]C particles at around 10wt.% with 15 mum WC at 5wt.% also providing improved wear resistance.

  12. Thermomechanical Contact Phenomena and Wear of Sliding Components

    DTIC Science & Technology

    1989-07-31

    seals. Many of those methods were used in this study. • • I I i II I I I I I I I l1 2. METHDS Sliding wear tests were conducted on Inconel 625 seal rings...wear. These coatings have been used successfully in reducing the wear of machine tools , aircraft and automobile engine parts, etc. It is only recently...scanning electron microscopy were tools employed to determine the wear behavior and wear mechanism associated with the various chromium carbide and tungsten

  13. Gravimetric wear analysis and particulate characterization of bilateral facet-augmentation system--PercuDyn™.

    PubMed

    Bhattacharya, Sanghita; Nayak, Aniruddh; Goel, Vijay K; Warren, Chris; Schlaegle, Steve; Ferrara, Lisa

    2010-01-01

    Dynamic stabilization systems are emerging as an alternative to fusion instrumentation. However, cyclic loading and micro-motion at various interfaces may produce wear debris leading to adverse tissue reactions such as osteolysis. Ten million cycles of wear test was performed for PercuDyn™ in axial rotation and the wear profile and the wear rate was mapped. A validation study was undertaken to assess the efficiency of wear debris collection which accounted for experimental errors. The mean wear debris measured at the end of 10 million cycles was 4.01 mg, based on the worst-case recovery rate of 68.2%. Approximately 40% of the particulates were less than 5 μm; 92% less than 10 μm. About 43% of particulates were spherical in shape, 27% particulates were ellipsoidal and the remaining particles were of irregular shapes. The PercuDyn™ exhibited an average polymeric wear rate of 0.4 mg/million cycles; substantially less than the literature derived studies for other motion preservation devices like the Bryan disc and Charité disc. Wear debris size and shape were also similar to these devices.

  14. Prevalence and Indicators of Tooth Wear among Chinese Adults

    PubMed Central

    Wei, Zhao; Du, Yangge; Zhang, Jing; Tai, Baojun

    2016-01-01

    Numerous epidemiological studies have focused on the prevalence and related indicators of tooth wear. However, no sufficient studies have been conducted with Chinese adults. The purpose of this study was to assess the prevalence of tooth wear and identify related indicators among adults aged 36 to 74 years in Wuhan City, P.R. China. A cross-sectional and analytic study was conducted with 720 participants, aged 35–49 yrs and 50–74 yrs, in 2014. Each age group included 360 participants, of which 50% were males and 50% were females. All participants completed a questionnaire before examination. Tooth wear was assessed using the modified Basic Erosive Wear Examination (BEWE) index. The data were analyzed using the chi-square test and binary logistic regression analysis. The prevalence of tooth wear was 67.5% and 100% in the 35–49 and 50–74 age groups, respectively. The prevalence of dentin exposure was 64.7% and 98.3%, respectively. A significantly higher prevalence of tooth wear and dentin exposure was found in the 50–74 yr group than in the 35–49 yr group (p < 0.05). Critical indicators of tooth wear and dentin exposure included high frequency of acidic drinks and foods consumption, low socio-economic status, and unilateral chewing. The frequency of changing toothbrushes and the habit of drinking water during meals were associated with tooth wear. In addition, the usage of hard-bristle toothbrushes and consuming vitamin C and aspirin were found to be linked with dentin exposure. In conclusion, the prevalence of tooth wear and dentin exposure observed in Chinese adults was high, and the results revealed an association between tooth wear and socio-behavioral risk indicators. PMID:27583435

  15. Scanning-electron-microscope used in real-time study of friction and wear

    NASA Technical Reports Server (NTRS)

    Brainard, W. A.; Buckley, D. H.

    1975-01-01

    Small friction and wear apparatus built directly into scanning-electron-microscope provides both dynamic observation and microscopic view of wear process. Friction and wear tests conducted using this system have indicated that considerable information can readily be gained.

  16. Tooth wear prevention: a quantitative and qualitative in vitro study.

    PubMed

    Kaidonis, J A; Gratiaen, J; Bhatia, N; Richards, L C; Townsend, G C

    2003-03-01

    Management of tooth wear from grinding presents a significant clinical challenge. Acrylic nightguards are often used to protect the teeth, but many patients still grind with these appliances. This study aimed to test the effectiveness of three lubricants in reducing enamel wear by using an electro-mechanical machine under controlled conditions, with a view to undertaking a subsequent longitudinal clinical study. Sectioned tooth specimens were worn against each other under different loads and with the addition of three different lubricants: calcium fluoride (CaF) powder, olive-oil, and a combination of calcium fluoride with olive-oil in the form of a slurry. Wear rates of enamel only were quantified by weighing the specimens, and resin replicas of the worn tooth surfaces were made for examination under a scanning electron microscope. All three lubricants reduced the amount of enamel wear significantly compared with wearing specimens without adding lubricants. Wear rate was influenced by the type of lubricant and the load applied. Wear rates were significantly less for olive-oil and the olive-oil/CaF slurry compared with CaF alone. The microwear detail differed between the three lubricants. This study has shown that enamel wear can be reduced using dry or wet lubricants between opposing teeth that are worn under controlled conditions. Further research is required to clarify their possible clinical applications.

  17. Time series analysis of tool wear in sheet metal stamping using acoustic emission

    NASA Astrophysics Data System (ADS)

    Vignesh Shanbhag, V.; Pereira, P. Michael; Rolfe, F. Bernard; Arunachalam, N.

    2017-09-01

    Galling is an adhesive wear mode that often affects the lifespan of stamping tools. Since stamping tools represent significant economic cost, even a slight improvement in maintenance cost is of high importance for the stamping industry. In other manufacturing industries, online tool condition monitoring has been used to prevent tool wear-related failure. However, monitoring the acoustic emission signal from a stamping process is a non-trivial task since the acoustic emission signal is non-stationary and non-transient. There have been numerous studies examining acoustic emissions in sheet metal stamping. However, very few have focused in detail on how the signals change as wear on the tool surface progresses prior to failure. In this study, time domain analysis was applied to the acoustic emission signals to extract features related to tool wear. To understand the wear progression, accelerated stamping tests were performed using a semi-industrial stamping setup which can perform clamping, piercing, stamping in a single cycle. The time domain features related to stamping were computed for the acoustic emissions signal of each part. The sidewalls of the stamped parts were scanned using an optical profilometer to obtain profiles of the worn part, and they were qualitatively correlated to that of the acoustic emissions signal. Based on the wear behaviour, the wear data can be divided into three stages: - In the first stage, no wear is observed, in the second stage, adhesive wear is likely to occur, and in the third stage severe abrasive plus adhesive wear is likely to occur. Scanning electron microscopy showed the formation of lumps on the stamping tool, which represents galling behavior. Correlation between the time domain features of the acoustic emissions signal and the wear progression identified in this study lays the basis for tool diagnostics in stamping industry.

  18. Study of Tool Wear Mechanisms and Mathematical Modeling of Flank Wear During Machining of Ti Alloy (Ti6Al4V)

    NASA Astrophysics Data System (ADS)

    Chetan; Narasimhulu, A.; Ghosh, S.; Rao, P. V.

    2015-07-01

    Machinability of titanium is poor due to its low thermal conductivity and high chemical affinity. Lower thermal conductivity of titanium alloy is undesirable on the part of cutting tool causing extensive tool wear. The main task of this work is to predict the various wear mechanisms involved during machining of Ti alloy (Ti6Al4V) and to formulate an analytical mathematical tool wear model for the same. It has been found from various experiments that adhesive and diffusion wear are the dominating wear during machining of Ti alloy with PVD coated tungsten carbide tool. It is also clear from the experiments that the tool wear increases with the increase in cutting parameters like speed, feed and depth of cut. The wear model was validated by carrying out dry machining of Ti alloy at suitable cutting conditions. It has been found that the wear model is able to predict the flank wear suitably under gentle cutting conditions.

  19. Effect of short LED lamp exposure on wear resistance, residual monomer and degree of conversion for Filtek Z250 and Tetric EvoCeram composites.

    PubMed

    Kopperud, Hilde M; Johnsen, Gaute F; Lamolle, Sébastien; Kleven, Inger S; Wellendorf, Hanne; Haugen, Håvard J

    2013-08-01

    The latest LED dental curing devices claim sufficient curing of restorative materials with short curing times. This study evaluates mechanical and chemical properties as a function of curing time of two commercial composite filling materials cured with three different LED lamps. The composites were Filtek Z250 (3M ESPE) and Tetric EvoCeram (Ivoclar Vivadent) and the LED curing devices were bluephase 16i (Ivoclar Vivadent), L.E.Demetron II (Kerr) and Mini L.E.D. (Satelec). Control samples were cured with a QTH-lamp (VCL 400, Kerr). The wear resistance after simulated tooth brushing, degree of conversion, curing depth, and amounts of residual monomers were measured after different curing times. The results of this study show that short curing time with high-intensity LEDs may influence the bulk properties of the materials, resulting in lower curing depth and increased residual monomer content. The measured surface properties of the materials, degree of conversion and wear resistance, were not affected by short curing times to the same extent. This study demonstrates that reduced exposure time with high intensity LEDs can result in composite restorations with inferior curing depth and increased leaching of monomers. Dentists are recommended to use sufficient curing times even with high intensity LEDs to ensure adequate curing and minimize the risk of monomer leaching. Copyright © 2013 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  20. Double gloves: a randomized trial to evaluate a simple strategy to reduce contamination in the operating room.

    PubMed

    Birnbach, David J; Rosen, Lisa F; Fitzpatrick, Maureen; Carling, Philip; Arheart, Kristopher L; Munoz-Price, L Silvia

    2015-04-01

    Oral flora, blood-borne pathogens, and bacterial contamination pose a direct risk of infection to patients and health care workers. We conducted a study in a simulated operating room using a newly validated technology to determine whether the use of 2 sets of gloves, with the outer set removed immediately after endotracheal intubation, may reduce this risk. Forty-one anesthesiology residents (PGY 2-4) were enrolled in a study consisting of individual or group simulation sessions. On entry to the simulated operating room, the residents were asked to perform an anesthetic induction and tracheal intubation timed to approximately 6 minutes; they were unaware of the study design. Of the 22 simulation sessions, 11 were conducted with the intubating resident wearing single gloves, and 11 with the intubating resident using double gloves with the outer pair removed after verified intubation. Before the start of the scenario, we coated the lips and inside of the mouth of the mannequin with a fluorescent marking gel as a surrogate pathogen. After the simulation, an observer examined 40 different sites using a handheld ultraviolet light in the operating room to determine the transfer of surrogate pathogens to the patient and the patient's environment. Residents who wore double gloves were instructed by a confederate nurse to remove the outer set immediately after completion of the intubation. Forty sites of potential intraoperative pathogen spread were identified and assigned a score. The difference in the rate of contamination between anesthesiology residents who wore single gloves versus those with double gloves was clinically and statistically significant. The number of sites that were contaminated in the operating room when the intubating resident wore single gloves was 20.3 ± 1.4 (mean ± SE); the number of contaminated sites when residents wore double gloves was 5.0 ± 0.7 (P < 0.001). The results of this study suggest that when an anesthesiologist wears 2 sets of gloves during laryngoscopy and intubation and then removes the outer set immediately after intubation, the contamination of the intraoperative environment is dramatically reduced.

  1. Wear Debris Characterization and Corresponding Biological Response: Artificial Hip and Knee Joints

    PubMed Central

    Nine, Md J.; Choudhury, Dipankar; Hee, Ay Ching; Mootanah, Rajshree; Osman, Noor Azuan Abu

    2014-01-01

    Wear debris, of deferent sizes, shapes and quantities, generated in artificial hip and knees is largely confined to the bone and joint interface. This debris interacts with periprosthetic tissue and may cause aseptic loosening. The purpose of this review is to summarize and collate findings of the recent demonstrations on debris characterization and their biological response that influences the occurrence in implant migration. A systematic review of peer-reviewed literature is performed, based on inclusion and exclusion criteria addressing mainly debris isolation, characterization, and biologic responses. Results show that debris characterization largely depends on their appropriate and accurate isolation protocol. The particles are found to be non-uniform in size and non-homogeneously distributed into the periprosthetic tissues. In addition, the sizes, shapes, and volumes of the particles are influenced by the types of joints, bearing geometry, material combination, and lubricant. Phagocytosis of wear debris is size dependent; high doses of submicron-sized particles induce significant level of secretion of bone resorbing factors. However, articles on wear debris from engineered surfaces (patterned and coated) are lacking. The findings suggest considering debris morphology as an important parameter to evaluate joint simulator and newly developed implant materials. PMID:28788496

  2. [Which hip articulation bearing for which patient? : Tribology of the future].

    PubMed

    Morlock, M M; Bishop, N; Kaddick, C

    2011-12-01

    Replacement of the hip joint has become an exceptionally successful procedure since the inauguration of the low friction principle by Charnley. Aseptic osteolysis and joint dislocation have been addressed by the development of wear-optimized materials and the introduction of larger heads. As an increase in head diameter against polyethylene causes wear increase, larger hard-on-hard bearings were introduced, which exhibit reduced wear and reduced dislocation risk with increasing head diameter. These findings were derived from standard simulator testing, not sufficiently considering the risk of fluid film breakdown under adverse conditions, which can cause a dramatic increase in wear and friction proportional to the head diameter. Such adverse conditions can occur clinically in patients due to several factors and have caused the presently observed unexpected problems with these new designs. Standardized preclinical testing has to be viewed as a minimum requirement but certainly not as a guarantee for the clinical success of new materials and designs even if the testing is adapted to the current patient requirements, which is presently not the case. The future of tribology lies in the prevention of adverse conditions in patients, the improvement and optimized use of proven existing materials and not in the use of new materials.

  3. The Tribological Properties of Several Silahydrocarbons for Use in Space Mechanisms

    NASA Technical Reports Server (NTRS)

    Jones, W. R., Jr.; Jansen, M. J.; Gschwender, L. J.; Snyder, C. E., Jr.; Sharma, S. K.; Predmore, R. E.; Dube, M. J.

    2001-01-01

    Silahydrocarbons are members of a relatively new class of liquid lubricants with great potential for use in space mechanisms. They are unimolecular species consisting of silicon, carbon, and hydrogen. They possess unique wear, viscosity, and volatility properties while retaining the ability to solubilize conventional additives. The tribological properties of several members of this class, including tri, tetra- and penta-compounds, are presented. These properties include: viscosity-temperature (ASTM D446), viscosity-pressure coefficient, vapor pressure, volatility, lubricant lifetimes, traction, reciprocating and four ball wear rates and bearing performance. Lubricant lifetimes were determined using a vacuum ball bearing simulator, the spiral orbit tribometer (SOT). Wear was measured using a Cameron Plint reciprocating tribometer and wear rates with a vacuum four ball tribometer. Conventional viscometry was used for viscosity-temperature measurements and a Knudsen cell for vapor pressure. Vacuum Thermogravimetric Analysis (TGA) was also used for volatility measurements. Pressure viscosity coefficients (a values) were estimated from EHL (elastohydrodynamic lubrication) film thickness measurements. Traction coefficients were measured with a twin disk traction rig. Bearing tests were performed in a vacuum bearing test facility. These properties are compared to existing state-of-the-art space lubricants.

  4. Tooth wear and wear investigations in dentistry.

    PubMed

    Lee, A; He, L H; Lyons, K; Swain, M V

    2012-03-01

    Tooth wear has been recognised as a major problem in dentistry. Epidemiological studies have reported an increasing prevalence of tooth wear and general dental practitioners see a greater number of patients seeking treatment with worn dentition. Although the dental literature contains numerous publications related to management and rehabilitation of tooth wear of varying aetiologies, our understanding of the aetiology and pathogenesis of tooth wear is still limited. The wear behaviour of dental biomaterials has also been extensively researched to improve our understanding of the underlying mechanisms and for the development of restorative materials with good wear resistance. The complex nature of tooth wear indicates challenges for conducting in vitro and in vivo wear investigations and a clear correlation between in vitro and in vivo data has not been established. The objective was to critically review the peer reviewed English-language literature pertaining to prevalence and aetiology of tooth wear and wear investigations in dentistry identified through a Medline search engine combined with hand-searching of the relevant literature, covering the period between 1960 and 2011. © 2011 Blackwell Publishing Ltd.

  5. How Does Wear Rate Compare in Well-functioning Total Hip and Knee Replacements? A Postmortem Polyethylene Liner Study.

    PubMed

    Pourzal, Robin; Knowlton, Christopher B; Hall, Deborah J; Laurent, Michel P; Urban, Robert M; Wimmer, Markus A

    2016-08-01

    The longevity of total hip (THR) and knee replacements (TKR) that used historical bearing materials of gamma-in-air sterilized UHMWPE was affected more by osteolysis in THRs than in TKRs, although osteolysis remains a concern in TKRs. Therefore, the study of polyethylene wear is still of interest for the knee, particularly because few studies have investigated volumetric material loss in tibial knee inserts. For this study, a unique collection of autopsy-retrieved TKR and THR components that were well-functioning at the time of retrieval was used to compare volumetric wear differences between hip and knee polyethylene components made from identical material. The following questions were addressed: (1) How much did the hip liners wear and what wear patterns did they exhibit? (2) How much did the knee inserts wear and what wear patterns did they exhibit? (3) What is the ratio between TKR and THR wear after controlling for implantation time and patient age? We compared 23 THR components (Harris-Galante [HG] and HG II) and 20 TKR components (Miller-Galante [MG II]) that were retrieved postmortem. The components were made from the same polyethylene formulation and with similar manufacturing and sterilization (gamma-in-air) processes. Twenty-one patients (12 males, nine females) had THRs and 16 (four males, 12 females) had TKRs. Patients who had TKRs had an older (p = 0.001) average age than patients who had THRs (age, 75 years; SD, 10, versus 66 years; SD, 12, respectively). Only well-functioning components were included in this study. Therefore, implants retrieved postmortem from physically active patients and implanted for at least 2 years were considered. In addition, only normally wearing TKR components were considered, ie, those with fatigue wear (delamination) were excluded. The wear volume of each component was measured using metrology. For the tibial inserts an autonomous mathematic reconstruction method was used for quantification. The acetabular liners of the THR group had a wear rate of 38 mm(3) per year (95% CI, 29-47 mm(3)/year). Excluding patients with low-activity, the wear rate was 47 mm(3) per year (95% CI, 37-56 mm(3)/year). The wear rate of normally wearing tibial inserts was 17 mm(3) per year (95% CI, -6 to 40 mm(3)/year). After controlling for the relevant confounding variable of age, we found a TKR/THR wear rate ratio of 0.5 (95% CI, 0.29-0.77) at 70 years of age with a slightly increasing difference with increasing age. Excluding delamination, TKRs exhibited lower articular wear rates than THRs for historical polyethylene in these two unique cohorts of postmortem retrievals. The lower TKR wear rate is in line with the lower incidence of osteolysis in TKRs compared with THRs.

  6. Study of Two-Body Wear Performance of Dental Materials.

    PubMed

    Hu, Xin; Zhang, Qian; Ning, Jia; Wu, Wenmeng; Li, Changyi

    2018-06-01

    The purpose of this study was to evaluate the two-body wear resistances of natural enamel and four dental materials in vitro. The testing machine was modified to form a type of pin-on-disk wear test apparatus. Four dental material specimens (Au-Pd alloy, Ag-Pd alloy, FiltekTMP60 and FiltekTMZ350 composite resins) and enamel were used as the pins, and a steatite ceramic grinding wheel was used as the abrasive counter face. The wear volume loss and the rigidity value was measured. The worn surface and the element analysis of the debris were analyzed. The wear volume loss of Au-Pd alloy and its steatite antagonists were the nearest to those of the dental enamel. SEM microphotographs showed that, the main wear mechanism of the dental materials was abrasive and adhesive wear. Au-Pd alloy had good wear resistance and was more suitable for dental applications than other three dental materials. Copyright © 2017 National Medical Association. Published by Elsevier Inc. All rights reserved.

  7. Effect of Tape Burnishing and Drive Use on Head Wear in Rotary Tape Drives

    NASA Astrophysics Data System (ADS)

    Bhushan, Bharat; Anderson, Reid M.; Koinkar, Vilas N.

    Three types of 12.7-mm wide metal particle tapes were studied. One of the tapes was calendered, whereas the other two tapes were additionally burnished one or two times using a proprietary process. Each type of tape was studied after 100 passes in the BetaCam SP drive and also in the virgin (0 pass) state. It was reported that in the case of the unburnished tape, head wear was high in the first pass and decreased during use. However, head wear for the double burnished tape was low for the first pass and increased during use. Whereas in the single burnished tape, head wear was low in the first pass and remained low. The objective of this study is to understand the mechanisms for loss and growth of head wear by correlating the surface characteristics of the tapes to head wear rate and to determine the changes in the surface characteristics occurring from 0 to 100 passes in the drive. It was found that summit density, mean and rms summit height, and mean and rms summit curvature correlate well to the head wear data. During manufacture and use in the drive, as the summit density, mean and rms summit height, and mean and rms summit curvature decrease, the head wear rate decreases. The mechanism for head wear is the initial ploughing of dense, sharp and high tape asperities into the surface of the head material resulting in a high head wear rate and a high coefficient of friction. Double burnishing during manufacturing removes high asperities, thus making the tape very smooth and possibly results in high adhesion and head wear growth with use. Chemical changes of the tape surface during double burnishing (not part of this study) also may be responsible for head wear growth during use.

  8. Polyethylene wear in Oxford unicompartmental knee replacement: a retrieval study of 47 bearings.

    PubMed

    Kendrick, B J L; Longino, D; Pandit, H; Svard, U; Gill, H S; Dodd, C A F; Murray, D W; Price, A J

    2010-03-01

    The Oxford Unicompartmental Knee replacement (UKR) was introduced as a design to reduce polyethylene wear. There has been one previous retrieval study involving this implant, which reported very low rates of wear in some specimens but abnormal patterns of wear in others. There has been no further investigation of these abnormal patterns. The bearings were retrieved from 47 patients who had received a medial Oxford UKR for anteromedial osteoarthritis of the knee. None had been studied previously. The mean time to revision was 8.4 years (sd 4.1), with 20 having been implanted for over ten years. The macroscopic pattern of polyethylene wear and the linear penetration were recorded for each bearing. The mean rate of linear penetration was 0.07 mm/year. The patterns of wear fell into three categories, each with a different rate of linear penetration; 1) no abnormal macroscopic wear and a normal articular surface, n = 16 (linear penetration rate = 0.01 mm/year); 2) abnormal macroscopic wear and normal articular surfaces with extra-articular impingement, n = 16 (linear penetration rate = 0.05 mm/year); 3) abnormal macroscopic wear and abnormal articular surfaces with intra-articular impingement +/- signs of non-congruous articulation, n = 15 (linear penetration rate = 0.12 mm/year). The differences in linear penetration rate were statistically significant (p < 0.001). These results show that very low rates of polyethylene wear are possible if the device functions normally. However, if the bearing displays suboptimal function (extra-articular, intra-articular impingement or incongruous articulation) the rates of wear increase significantly.

  9. Grid-to-rod flow-induced impact study for PWR fuel in reactor

    DOE PAGES

    Jiang, Hao; Qu, Jun; Lu, Roger Y.; ...

    2016-06-10

    The source for grid-to-rod fretting in a pressurized water nuclear reactor (PWR) is the dynamic contact impact from hydraulic flow-induced fuel assembly vibration. In order to support grid-to-rod fretting wear mitigation research, finite element analysis (FEA) was used to evaluate the hydraulic flow-induced impact intensity between the fuel rods and the spacer grids. Three-dimensional FEA models, with detailed geometries of the dimple and spring of the actual spacer grids along with fuel rods, were developed for flow impact simulation. The grid-to-rod dynamic impact simulation provided insights of the contact phenomena at grid-rod interface. Finally, it is an essential and effectivemore » way to evaluate contact forces and provide guidance for simulative bench fretting-impact tests.« less

  10. Materials Test Program, Contact Power Collection for High Speed Tracked Vehicles

    DOT National Transportation Integrated Search

    1971-01-01

    A test program is defined for determining the failure modes and wear characteristics for brushes used to collect electrical power from the wayside for high speed tracked vehicles. Simulation of running conditions and the necessary instrumentation for...

  11. CobraPLA Insertion by anesthetists and non-anesthetists wearing unconventional protective gear: a prospective study in humans.

    PubMed

    Ben-Abraham, Ron; Flaishon, Ron; Sotman, Alexander; Ekstein, Perla; Ezri, Tiberiu; Ogorek, Daniel; Weinbroum, Avi A

    2008-07-01

    The threat of a mass casualty unconventional attack has challenged the medical community to devise means for providing rapid and reliable emergent airway control under chaotic conditions by inexperienced medical personnel dressed in self protective gear. Since endotracheal intubation may not be feasible under those conditions, other extraglottic devices should be considered. We assessed the performance of anesthesia and non-anesthesia residents in inserting the CobraPLA, a supraglottic airway device, on consecutive anesthetized patients, to assess its potential use under simulated conditions. Anesthesia and non-anesthesia residents wearing either surgical scrubs or complete anti-chemical gear inserted the CobraPLA in anesthetized patients. If post-trial positive pressure ventilation via the CobraPLA was unsuccessful, an LMA or endotracheal tube was inserted in its stead. It took anesthesia residents 57+/-23 sec and 43+/-13 sec (P<0.05) to place the CobraPLA while wearing anti-chemical gear and surgical scrubs, respectively. Non-anesthesia residents wearing anti-chemical gear performed worse than anesthetists in their first insertion (73+/-9 sec, P<0.05), but after the brief training period they performed as well as their colleagues anesthetists (58+/-10 sec, P=NS). Post-trial, twenty-one CobraPLA (42%) leaked, preventing adequate positive-pressure ventilation: 13 devices (26% of the total) required replacements. Anti-chemical protective gear slowed the insertion of the CobraPLA by anesthetists, and more so by other residents inexperienced in airway management. In 26% of the cases CobraPLA was inadequate for positive pressure ventilation.

  12. Tribocorrosion behavior of biofunctional titanium oxide films produced by micro-arc oxidation: Synergism and mechanisms.

    PubMed

    Marques, Isabella da Silva Vieira; Alfaro, Maria Fernanda; Cruz, Nilson Cristino da; Mesquita, Marcelo Ferraz; Takoudis, Christos; Sukotjo, Cortino; Mathew, Mathew T; Barão, Valentim Adelino Ricardo

    2016-07-01

    Dental implants, inserted into the oral cavity, are subjected to a synergistic interaction of wear and corrosion (tribocorrosion), which may lead to implant failures. The objective of this study was to investigate the tribocorrosion behavior of Ti oxide films produced by micro-arc oxidation (MAO) under oral environment simulation. MAO was conducted under different conditions as electrolyte composition: Ca/P (0.3M/0.02M or 0.1M/0.03M) incorporated with/without Ag (0.62g/L) or Si (0.04M); and treatment duration (5 and 10min). Non-coated and sandblasted samples were used as controls. The surfaces morphology, topography and chemical composition were assessed to understand surface properties. ANOVA and Tukey׳s HSD tests were used (α=0.05). Biofunctional porous oxide layers were obtained. Higher Ca/P produced larger porous and harder coatings when compared to non-coated group (p<0.001), due to the presence of rutile crystalline structure. The total mass loss (Kwc), which includes mass loss due to wear (Kw) and that due to corrosion (Kc) were determined. The dominant wear regime was found for higher Ca/P groups (Kc/Kw≈0.05) and a mechanism of wear-corrosion for controls and lower Ca/P groups (Kc/Kw≈0.11). The group treated for 10min and enriched with Ag presented the lowest Kwc (p<0.05). Overall, MAO process was able to produce biofunctional oxide films with improved surface features, working as tribocorrosion resistant surfaces. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Effect of spherical Au nanoparticles on nanofriction and wear reduction in dry and liquid environments

    PubMed Central

    Maharaj, Dave

    2012-01-01

    Summary Nano-object additives are used in tribological applications as well as in various applications in liquids requiring controlled manipulation and targeting. On the macroscale, nanoparticles in solids and liquids have been shown to reduce friction and wear. On the nanoscale, atomic force microscopy (AFM) studies have been performed in single- and multiple-nanoparticle contact, in dry environments, to characterize friction forces and wear. However, limited studies in submerged liquid environments have been performed and further studies are needed. In this paper, spherical Au nanoparticles were studied for their effect on friction and wear under dry conditions and submerged in water. In single-nanoparticle contact, individual nanoparticles, deposited on silicon, were manipulated with a sharp tip and the friction force was determined. Multiple-nanoparticle contact sliding experiments were performed on nanoparticle-coated silicon with a glass sphere. Wear tests were performed on the nanoscale with AFM as well as on the macroscale by using a ball-on-flat tribometer to relate friction and wear reduction on the nanoscale and macroscale. Results indicate that the addition of Au nanoparticles reduces friction and wear. PMID:23213639

  14. Development of horizontal tooth wear in maxillary anterior teeth from five to 18 years of age.

    PubMed

    Nyström, M; Könönen, M; Alaluusua, S; Evälahti, M; Vartiovaara, J

    1990-11-01

    Sizes of horizontal wear facets of maxillary anterior teeth were studied longitudinally from the primary dentition at age five to the young adult dentition at the age of 18 years. By a planimetric method, we calculated the wear areas on dental casts taken at the ages of five, ten, 14, and 18 years from the dentition of 39 healthy, orthodontically untreated subjects with good morphological occlusion. For young adults, we also studied the association between the amount of wear and reported parafunctions, maximal bite force, salivary buffer capacity, salivary flow rate, and some cephalometric variables. Size of wear facets on all anterior teeth increased with age. Significant correlations were found between the total wear areas of the six anterior primary teeth at five years of age and those of their permanent successors at age 14 (r = 0.44) and 18 (r = 0.39). For an individual, tooth wear at five years of age was, however, of low predictive value for tooth wear in young adulthood, whereas tooth wear at 14 years of age predicted it well (r = 0.89). Highest correlations between tooth wear and background factors at 18 years of age were found for maximal anterior bite force (r = 0.44) and for the size of the gonial angle (r = -0.31). Wear of anterior teeth was not associated with reported parafunctions in young adulthood.

  15. Investigations of wear particles and selected cytokines in human osteoarthritic knee joints.

    PubMed

    Wang, Meiling; Ketheesan, Natkunam; Peng, Zhongxiao

    2014-11-01

    Inflammation of the synovial membrane (synovitis) is considered to drive the process that leads to osteoarthritis. However, the relationships between the mediators of inflammation and the properties of wear particles are not fully understood. In this study, the levels of IL-6 and IL-8 were assessed in different grades of osteoarthritis to determine whether their concentrations in the synovial fluid correlate with specific characteristics of wear particles. This study has found that the size, adhesion and nano-surface roughness of wear particles have medium strong to strong correlations with IL-6 and IL-8. This study provided evidence that the characteristics of wear particles contain valuable information for grading the disease process and the need for further evaluation of the association of properties of wear particles and the inflammatory process. © IMechE 2014.

  16. Effect of initial contact surface condition on the friction and wear properties of bearing steel in cyclic reciprocating sliding contact

    NASA Astrophysics Data System (ADS)

    Tanaka, Y.; Endo, M.; Moriyama, S.

    2017-05-01

    Delamination failure is one of the most important engineering problems. This failure can frequently be detrimental to rolling contact machine elements such as bearings, gear wheels, etc. This phenomenon, called rolling contact fatigue, has a close relationship not only with opening-mode but also with shear-mode fatigue crack growth. The crack face interference is known to significantly affect the shear-mode fatigue crack propagation and its threshold behavior. Quantitative investigation on friction and wear at fatigue crack faces in the material is essentially impossible. Previously, thus, a novel ring-on-ring test by making use of fatigue testing machine was proposed to simulate a cyclic reciprocating sliding contact of crack surfaces. However, this test procedure had some problems. For instance, in order to achieve the uniform contact at the start of test, the rubbing of specimens must be conducted in advance. By this treatment, the specimen surfaces were already damaged before the test. In this study, an improvement of experimental method was made to perform the test using the damage-free specimens. The friction and wear properties for heat-treated high carbon-chromium bearing steel were investigated with this new method and the results were compared to the results obtained by using the initially damaged specimens.

  17. Effect of Deformation Mode on the Wear Behavior of NiTi Shape Memory Alloys

    NASA Astrophysics Data System (ADS)

    Yan, Lina; Liu, Yong

    2016-06-01

    Owing to good biocompatibility, good fatigue resistance, and excellent superelasticity, various types of bio-medical devices based on NiTi shape memory alloy (SMA) have been developed. Due to the complexity in deformation mode in service, for example NiTi implants, accurate assessment/prediction of the surface wear process is difficult. This study aims at providing a further insight into the effect of deformation mode on the wear behavior of NiTi SMA. In the present study, two types of wear testing modes were used, namely sliding wear mode and reciprocating wear mode, to investigate the effect of deformation mode on the wear behavior of NiTi SMA in both martensitic and austenitic states. It was found that, when in martensitic state and under high applied loads, sliding wear mode resulted in more surface damage as compared to that under reciprocating wear mode. When in austenitic state, although similar trends in the coefficient of friction were observed, the coefficient of friction and surface damage in general is less under reciprocating mode than under sliding mode. These observations were further discussed in terms of different deformation mechanisms involved in the wear tests, in particular, the reversibility of martensite variant reorientation and stress-induced phase transformation, respectively.

  18. Experimental prediction of tube support interaction characteristics in steam generators: Volume 2, Westinghouse Model 51 flow entrance region: Topical report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Haslinger, K.H.

    Tube-to-tube support interaction characterisitics were determined experimentally on a single tube, multi-span geometry, representative of the Westinghouse Model 51 steam generator economizer design. Results, in part, became input for an autoclave type wear test program on steam generator tubes, performed by Kraftwerk Union (KWU). More importantly, the test data reported here have been used to validate two analytical wear prediction codes; the WECAN code, which was developed by Westinghouse, and the ABAQUS code which has been enhanced for EPRI by Foster Wheeler to enable simulation of gap conditions (including fluid film effects) for various support geometries.

  19. Tribochemical wear of single crystal aluminum in NaCl solution studied by atomic force microscopy

    NASA Astrophysics Data System (ADS)

    Cai, M.; Langford, S. C.; Dickinson, J. T.

    2011-09-01

    We report a systematic study of chemically enhanced wear of single crystal aluminum surfaces in aqueous solutions using an environmentally equipped atomic force microscope (AFM). The experiments were conducted by using a standard Si3N4 AFM tip to apply a localized force on a polished, single crystal aluminum (110) surface. Most measurements were performed in 0.5 M NaCl solution. We show the effect of applied force, number of scans, chemical solution, and temperature on the chemical-mechanical wear of aluminum on the nanometer scale. Aggressive chemical environments significantly enhance the wear of aluminum relative to scanning in dry air. Quantitative measurements show that the wear volume increases in proportion to the square root of force and the number of scans (or time). Arrhenius plots of wear volume versus temperature are consistent with an activation energy of 31 kJ/mol for scanning in 0.5 M NaCl. The wear of the AFM tip and the aluminum substrate is explained in terms of the synergistic surface chemical reactions and mechanical action of the tip. We compare these results to previous studies of AFM wear of silicate glass.

  20. Experimental wear behavioral studies of as-cast and 5 hr homogenized Al25Mg2Si2Cu4Ni alloy at constant load based on taguchi method

    NASA Astrophysics Data System (ADS)

    Harlapur, M. D.; Mallapur, D. G.; Udupa, K. Rajendra

    2018-04-01

    In the present study, an experimental study of the volumetric wear behaviour of Aluminium (Al-25Mg2Si2Cu4Ni) alloy in as cast and 5Hr homogenized with T6 heat treatment is carried out at constant load. The Pin on disc apparatus was used to carry out the sliding wear test. Taguchi method based on L-16 orthogonal array was employed to evaluate the data on the wear behavior. Signal-to-noise ratio among the objective of smaller the better and mean of means results were used. General regression model is obtained by correlation. Lastly confirmation test was completed to compose a comparison between the experimental results foreseen from the mention correlation. The mathematical model reveals the load has maximum contribution on the wear rate compared to speed. Scanning Electron Microscope was used to analyze the worn-out wear surfaces. Wear results show that 5Hr homogenized Al-25Mg2Si2Cu4Ni alloy samples with T6 treated had better volumetric wear resistance as compared to as cast samples.

Top