Molecular Simulation of Gas Solubility in Nitrile Butadiene Rubber.
Khawaja, M; Sutton, A P; Mostofi, A A
2017-01-12
Molecular simulation is used to compute the solubility of small gases in nitrile butadiene rubber (NBR) with a Widom particle-insertion technique biased by local free volume. The convergence of the method is examined as a function of the number of snapshots upon which the insertions are performed and the number of insertions per snapshot and is compared to the convergence of the unbiased Widom insertion technique. The effect of varying the definition of local free volume is also investigated. The acrylonitrile content of the polymer is altered to examine its influence on the solubility of helium, CO 2 , and H 2 O, and the solubilities of polar gases are found to be enhanced relative to those of nonpolar gases, in qualitative agreement with experiment. To probe this phenomenon further, the solubilities are decomposed into contributions from the neighborhoods of different atoms, using a Voronoi cell construction, and a strong bias is found for CO 2 and H 2 O in particular to be situated near nitrogen sites in the elastomer. Temperature is shown to suppress the solubility of CO 2 and H 2 O but to increase that of helium. Increasing pressure is found to suppress the solubility of all gases but at different rates, according to a balance between their molecular sizes and electrostatic interactions with the polymer. These results are relevant to the use of NBR seals at elevated temperatures and pressures, such as in oil and gas wells.
Defining the free-energy landscape of curvature-inducing proteins on membrane bilayers
Tourdot, Richard W.; Ramakrishnan, N.; Radhakrishnan, Ravi
2015-01-01
Curvature-sensing and curvature-remodeling proteins, such as Amphiphysin, Epsin, and Exo70, are known to reshape cell membranes, and this remodeling event is essential for key biophysical processes such as tubulation, exocytosis, and endocytosis. Curvature-inducing proteins can act as curvature sensors; they aggregate to membrane regions matching their intrinsic curvature; as well as induce curvature in cell membranes to stabilize emergent high curvature, nonspherical, structures such as tubules, discs, and caveolae. A definitive understanding of the interplay between protein recruitment and migration, the evolution of membrane curvature, and membrane morphological transitions is emerging but remains incomplete. Here, within a continuum framework and using the machinery of Monte Carlo simulations, we introduce and compare three free-energy methods to delineate the free-energy landscape of curvature-inducing proteins on bilayer membranes. We demonstrate the utility of the Widom test particle (or field) insertion methodology in computing the excess chemical potentials associated with curvature-inducing proteins on the membrane—in particular, we use this method to track the onset of morphological transitions in the membrane at elevated protein densities. We validate this approach by comparing the results from the Widom method with those of thermodynamic integration and Bennett acceptance ratio methods. Furthermore, the predictions from the Widom method have been tested against analytical calculations of the excess chemical potential at infinite dilution. Our results are useful in precisely quantifying the free-energy landscape, and also in determining the phase boundaries associated with curvature-induction, curvature-sensing, and morphological transitions. This approach can be extended to studies exploring the role of thermal fluctuations and other external (control) variables, such as membrane excess area, in shaping curvature-mediated interactions on bilayer membranes. PMID:25215768
Defining the free-energy landscape of curvature-inducing proteins on membrane bilayers.
Tourdot, Richard W; Ramakrishnan, N; Radhakrishnan, Ravi
2014-08-01
Curvature-sensing and curvature-remodeling proteins, such as Amphiphysin, Epsin, and Exo70, are known to reshape cell membranes, and this remodeling event is essential for key biophysical processes such as tubulation, exocytosis, and endocytosis. Curvature-inducing proteins can act as curvature sensors; they aggregate to membrane regions matching their intrinsic curvature; as well as induce curvature in cell membranes to stabilize emergent high curvature, nonspherical, structures such as tubules, discs, and caveolae. A definitive understanding of the interplay between protein recruitment and migration, the evolution of membrane curvature, and membrane morphological transitions is emerging but remains incomplete. Here, within a continuum framework and using the machinery of Monte Carlo simulations, we introduce and compare three free-energy methods to delineate the free-energy landscape of curvature-inducing proteins on bilayer membranes. We demonstrate the utility of the Widom test particle (or field) insertion methodology in computing the excess chemical potentials associated with curvature-inducing proteins on the membrane-in particular, we use this method to track the onset of morphological transitions in the membrane at elevated protein densities. We validate this approach by comparing the results from the Widom method with those of thermodynamic integration and Bennett acceptance ratio methods. Furthermore, the predictions from the Widom method have been tested against analytical calculations of the excess chemical potential at infinite dilution. Our results are useful in precisely quantifying the free-energy landscape, and also in determining the phase boundaries associated with curvature-induction, curvature-sensing, and morphological transitions. This approach can be extended to studies exploring the role of thermal fluctuations and other external (control) variables, such as membrane excess area, in shaping curvature-mediated interactions on bilayer membranes.
Thermodynamic free energy methods to investigate shape transitions in bilayer membranes.
Ramakrishnan, N; Tourdot, Richard W; Radhakrishnan, Ravi
2016-06-01
The conformational free energy landscape of a system is a fundamental thermodynamic quantity of importance particularly in the study of soft matter and biological systems, in which the entropic contributions play a dominant role. While computational methods to delineate the free energy landscape are routinely used to analyze the relative stability of conformational states, to determine phase boundaries, and to compute ligand-receptor binding energies its use in problems involving the cell membrane is limited. Here, we present an overview of four different free energy methods to study morphological transitions in bilayer membranes, induced either by the action of curvature remodeling proteins or due to the application of external forces. Using a triangulated surface as a model for the cell membrane and using the framework of dynamical triangulation Monte Carlo, we have focused on the methods of Widom insertion, thermodynamic integration, Bennett acceptance scheme, and umbrella sampling and weighted histogram analysis. We have demonstrated how these methods can be employed in a variety of problems involving the cell membrane. Specifically, we have shown that the chemical potential, computed using Widom insertion, and the relative free energies, computed using thermodynamic integration and Bennett acceptance method, are excellent measures to study the transition from curvature sensing to curvature inducing behavior of membrane associated proteins. The umbrella sampling and WHAM analysis has been used to study the thermodynamics of tether formation in cell membranes and the quantitative predictions of the computational model are in excellent agreement with experimental measurements. Furthermore, we also present a method based on WHAM and thermodynamic integration to handle problems related to end-point-catastrophe that are common in most free energy methods.
NASA Astrophysics Data System (ADS)
Boda, Dezső; Giri, Janhavi; Henderson, Douglas; Eisenberg, Bob; Gillespie, Dirk
2011-02-01
The selectivity filter of the L-type calcium channel works as a Ca2 + binding site with a very large affinity for Ca2 + versus Na+. Ca2 + replaces half of the Na+ ions in the filter even when these ions are present in 1 μM and 30 mM concentrations in the bath, respectively. The energetics of this strong selectivity is analyzed in this paper. We use Widom's particle insertion method to compute the space-dependent profiles of excess chemical potential in our grand canonical Monte Carlo simulations. These profiles define the free-energy landscape for the various ions. Following Gillespie [Biophys. J. 94, 1169 (2008)], the difference of the excess chemical potentials for the two competing ions defines the advantage that one of the ions has over the other in the competition for space in the crowded selectivity filter. These advantages depend on ionic bath concentrations: the ion that is present in the bath in larger quantity (Na+) has the "number" advantage which is balanced by the free-energy advantage of the other ion (Ca2 +). The excess chemical potentials are decomposed into hard sphere exclusion and electrostatic components. The electrostatic terms correspond to interactions with the mean electric field produced by ions and induced charges as well to ionic correlations beyond the mean field description. Dielectrics are needed to produce micromolar Ca2 + versus Na+ selectivity in the L-type channel. We study the behavior of these terms with changes in bath concentrations of ions, charges, and diameters of ions, as well as geometrical parameters such as radius of the pore and the dielectric constant of the protein. Ion selectivity in calcium binding proteins probably has a similar mechanism.
Boda, Dezso; Giri, Janhavi; Henderson, Douglas; Eisenberg, Bob; Gillespie, Dirk
2011-02-07
The selectivity filter of the L-type calcium channel works as a Ca(2+) binding site with a very large affinity for Ca(2+) versus Na(+). Ca(2+) replaces half of the Na(+) ions in the filter even when these ions are present in 1 μM and 30 mM concentrations in the bath, respectively. The energetics of this strong selectivity is analyzed in this paper. We use Widom's particle insertion method to compute the space-dependent profiles of excess chemical potential in our grand canonical Monte Carlo simulations. These profiles define the free-energy landscape for the various ions. Following Gillespie [Biophys. J. 94, 1169 (2008)], the difference of the excess chemical potentials for the two competing ions defines the advantage that one of the ions has over the other in the competition for space in the crowded selectivity filter. These advantages depend on ionic bath concentrations: the ion that is present in the bath in larger quantity (Na(+)) has the "number" advantage which is balanced by the free-energy advantage of the other ion (Ca(2+)). The excess chemical potentials are decomposed into hard sphere exclusion and electrostatic components. The electrostatic terms correspond to interactions with the mean electric field produced by ions and induced charges as well to ionic correlations beyond the mean field description. Dielectrics are needed to produce micromolar Ca(2+) versus Na(+) selectivity in the L-type channel. We study the behavior of these terms with changes in bath concentrations of ions, charges, and diameters of ions, as well as geometrical parameters such as radius of the pore and the dielectric constant of the protein. Ion selectivity in calcium binding proteins probably has a similar mechanism.
A new potential for the numerical simulations of electrolyte solutions on a hypersphere
NASA Astrophysics Data System (ADS)
Caillol, Jean-Michel
1993-12-01
We propose a new way of performing numerical simulations of the restricted primitive model of electrolytes—and related models—on a hypersphere. In this new approach, the system is viewed as a single component fluid of charged bihard spheres constrained to move at the surface of a four dimensional sphere. A charged bihard sphere is defined as the rigid association of two antipodal charged hard spheres of opposite signs. These objects interact via a simple analytical potential obtained by solving the Poisson-Laplace equation on the hypersphere. This new technique of simulation enables a precise determination of the chemical potential of the charged species in the canonical ensemble by a straightforward application of Widom's insertion method. Comparisons with previous simulations demonstrate the efficiency and the reliability of the method.
Considering Horn's Parallel Analysis from a Random Matrix Theory Point of View.
Saccenti, Edoardo; Timmerman, Marieke E
2017-03-01
Horn's parallel analysis is a widely used method for assessing the number of principal components and common factors. We discuss the theoretical foundations of parallel analysis for principal components based on a covariance matrix by making use of arguments from random matrix theory. In particular, we show that (i) for the first component, parallel analysis is an inferential method equivalent to the Tracy-Widom test, (ii) its use to test high-order eigenvalues is equivalent to the use of the joint distribution of the eigenvalues, and thus should be discouraged, and (iii) a formal test for higher-order components can be obtained based on a Tracy-Widom approximation. We illustrate the performance of the two testing procedures using simulated data generated under both a principal component model and a common factors model. For the principal component model, the Tracy-Widom test performs consistently in all conditions, while parallel analysis shows unpredictable behavior for higher-order components. For the common factor model, including major and minor factors, both procedures are heuristic approaches, with variable performance. We conclude that the Tracy-Widom procedure is preferred over parallel analysis for statistically testing the number of principal components based on a covariance matrix.
On the Tracy-Widomβ Distribution for β=6
NASA Astrophysics Data System (ADS)
Grava, Tamara; Its, Alexander; Kapaev, Andrei; Mezzadri, Francesco
2016-11-01
We study the Tracy-Widom distribution function for Dyson's β-ensemble with β = 6. The starting point of our analysis is the recent work of I. Rumanov where he produces a Lax-pair representation for the Bloemendal-Virág equation. The latter is a linear PDE which describes the Tracy-Widom functions corresponding to general values of β. Using his Lax pair, Rumanov derives an explicit formula for the Tracy-Widom β=6 function in terms of the second Painlevé transcendent and the solution of an auxiliary ODE. Rumanov also shows that this formula allows him to derive formally the asymptotic expansion of the Tracy-Widom function. Our goal is to make Rumanov's approach and hence the asymptotic analysis it provides rigorous. In this paper, the first one in a sequel, we show that Rumanov's Lax-pair can be interpreted as a certain gauge transformation of the standard Lax pair for the second Painlevé equation. This gauge transformation though contains functional parameters which are defined via some auxiliary nonlinear ODE which is equivalent to the auxiliary ODE of Rumanov's formula. The gauge-interpretation of Rumanov's Lax-pair allows us to highlight the steps of the original Rumanov's method which needs rigorous justifications in order to make the method complete. We provide a rigorous justification of one of these steps. Namely, we prove that the Painlevé function involved in Rumanov's formula is indeed, as it has been suggested by Rumanov, the Hastings-McLeod solution of the second Painlevé equation. The key issue which we also discuss and which is still open is the question of integrability of the auxiliary ODE in Rumanov's formula. We note that this question is crucial for the rigorous asymptotic analysis of the Tracy-Widom function. We also notice that our work is a partial answer to one of the problems related to the β-ensembles formulated by Percy Deift during the June 2015 Montreal Conference on integrable systems.
Supercritical Anomalies and the Widom Line for the Isostructural Phase Transition in Solids
NASA Astrophysics Data System (ADS)
Tareyeva, E. E.; Fomin, Yu. D.; Tsiok, E. N.; Ryzhov, V. N.
2018-01-01
The representation of the Widom line as a line of maximums of the correlation length and a whole set of thermodynamic response functions above the critical point were introduced to describe anomalies observed in water above the hypothetical critical point of the liquid-liquid transition. The supercritical region for the gas-liquid transition was also described later in terms of the Widom line. It is natural to assume that an analogue of the Widom line also exists in the supercritical region for the first-order isostructural transition in crystals, which ends at a critical point. We use a simple semiphenomenological model, close in spirit the van der Waals theory, to study the properties of the new Widom line. We calculate the thermodynamic response functions above the critical point of the isostructural transition and find their maximums determining the Widom line position.
NASA Astrophysics Data System (ADS)
Ustinov, E. A.
2017-01-01
The paper aims at a comparison of techniques based on the kinetic Monte Carlo (kMC) and the conventional Metropolis Monte Carlo (MC) methods as applied to the hard-sphere (HS) fluid and solid. In the case of the kMC, an alternative representation of the chemical potential is explored [E. A. Ustinov and D. D. Do, J. Colloid Interface Sci. 366, 216 (2012)], which does not require any external procedure like the Widom test particle insertion method. A direct evaluation of the chemical potential of the fluid and solid without thermodynamic integration is achieved by molecular simulation in an elongated box with an external potential imposed on the system in order to reduce the particle density in the vicinity of the box ends. The existence of rarefied zones allows one to determine the chemical potential of the crystalline phase and substantially increases its accuracy for the disordered dense phase in the central zone of the simulation box. This method is applicable to both the Metropolis MC and the kMC, but in the latter case, the chemical potential is determined with higher accuracy at the same conditions and the number of MC steps. Thermodynamic functions of the disordered fluid and crystalline face-centered cubic (FCC) phase for the hard-sphere system have been evaluated with the kinetic MC and the standard MC coupled with the Widom procedure over a wide range of density. The melting transition parameters have been determined by the point of intersection of the pressure-chemical potential curves for the disordered HS fluid and FCC crystal using the Gibbs-Duhem equation as a constraint. A detailed thermodynamic analysis of the hard-sphere fluid has provided a rigorous verification of the approach, which can be extended to more complex systems.
Widom Delta of Supercritical Gas-Liquid Coexistence.
Ha, Min Young; Yoon, Tae Jun; Tlusty, Tsvi; Jho, Yongseok; Lee, Won Bo
2018-04-05
Density fluctuations and the Widom line are of great importance in understanding the critical phenomena and the behaviors of supercritical fluids (SCFs). We report on the direct classification of liquid-like and gas-like molecules coexisting in the SCF, identified by machine learning analysis on simulation data. The deltoid coexistence region encloses the Widom line and may therefore be termed the Widom delta. Number fractions of gas-like and liquid-like particles are found to undergo continuous transition across the delta, following a simplified two-state model. These fractions are closely related to the magnitude of supercritical anomaly, which originates from the fluctuation between the two types. This suggests a microscopic view of the SCF as a mixture of liquid-like and gas-like structures, providing an integrative explanation to the anomalous behaviors near the critical point and the Widom line.
Raman, Abhinav S; Li, Huiyong; Chiew, Y C
2018-01-07
Supercritical oxygen, a cryogenic fluid, is widely used as an oxidizer in jet propulsion systems and is therefore of paramount importance in gaining physical insights into processes such as transcritical and supercritical vaporization. It is well established in the scientific literature that the supercritical state is not homogeneous but, in fact, can be demarcated into regions with liquid-like and vapor-like properties, separated by the "Widom line." In this study, we identified the Widom line for oxygen, constituted by the loci of the extrema of thermodynamic response functions (heat capacity, volumetric thermal expansion coefficient, and isothermal compressibility) in the supercritical region, via atomistic molecular dynamics simulations. We found that the Widom lines derived from these response functions all coincide near the critical point until about 25 bars and 15-20 K, beyond which the isothermal compressibility line begins to deviate. We also obtained the crossover from liquid-like to vapor-like behavior of the translational diffusion coefficient, shear viscosity, and rotational relaxation time of supercritical oxygen. While the crossover of the translational diffusion coefficient and shear viscosity coincided with the Widom lines, the rotational relaxation time showed a crossover that was largely independent of the Widom line. Further, we characterized the clustering behavior and percolation transition of supercritical oxygen molecules, identified the percolation threshold based on the fractal dimension of the largest cluster and the probability of finding a cluster that spans the system in all three dimensions, and found that the locus of the percolation threshold also coincided with the isothermal compressibility Widom line. It is therefore clear that supercritical oxygen is far more complex than originally perceived and that the Widom line, dynamical crossovers, and percolation transitions serve as useful routes to better our understanding of the supercritical state.
NASA Astrophysics Data System (ADS)
Raman, Abhinav S.; Li, Huiyong; Chiew, Y. C.
2018-01-01
Supercritical oxygen, a cryogenic fluid, is widely used as an oxidizer in jet propulsion systems and is therefore of paramount importance in gaining physical insights into processes such as transcritical and supercritical vaporization. It is well established in the scientific literature that the supercritical state is not homogeneous but, in fact, can be demarcated into regions with liquid-like and vapor-like properties, separated by the "Widom line." In this study, we identified the Widom line for oxygen, constituted by the loci of the extrema of thermodynamic response functions (heat capacity, volumetric thermal expansion coefficient, and isothermal compressibility) in the supercritical region, via atomistic molecular dynamics simulations. We found that the Widom lines derived from these response functions all coincide near the critical point until about 25 bars and 15-20 K, beyond which the isothermal compressibility line begins to deviate. We also obtained the crossover from liquid-like to vapor-like behavior of the translational diffusion coefficient, shear viscosity, and rotational relaxation time of supercritical oxygen. While the crossover of the translational diffusion coefficient and shear viscosity coincided with the Widom lines, the rotational relaxation time showed a crossover that was largely independent of the Widom line. Further, we characterized the clustering behavior and percolation transition of supercritical oxygen molecules, identified the percolation threshold based on the fractal dimension of the largest cluster and the probability of finding a cluster that spans the system in all three dimensions, and found that the locus of the percolation threshold also coincided with the isothermal compressibility Widom line. It is therefore clear that supercritical oxygen is far more complex than originally perceived and that the Widom line, dynamical crossovers, and percolation transitions serve as useful routes to better our understanding of the supercritical state.
Similarity law for Widom lines and coexistence lines
NASA Astrophysics Data System (ADS)
Banuti, D. T.; Raju, M.; Ihme, M.
2017-05-01
The coexistence line of a fluid separates liquid and gaseous states at subcritical pressures, ending at the critical point. Only recently, it became clear that the supercritical state space can likewise be divided into regions with liquidlike and gaslike properties, separated by an extension to the coexistence line. This crossover line is commonly referred to as the Widom line, and is characterized by large changes in density or enthalpy, manifesting as maxima in the thermodynamic response functions. Thus, a reliable representation of the coexistence line and the Widom line is important for sub- and supercritical applications that depend on an accurate prediction of fluid properties. While it is known for subcritical pressures that nondimensionalization with the respective species critical pressures pcr and temperatures Tcr only collapses coexistence line data for simple fluids, this approach is used for Widom lines of all fluids. However, we show here that the Widom line does not adhere to the corresponding states principle, but instead to the extended corresponding states principle. We resolve this problem in two steps. First, we propose a Widom line functional based on the Clapeyron equation and derive an analytical, species specific expression for the only parameter from the Soave-Redlich-Kwong equation of state. This parameter is a function of the acentric factor ω and compares well with experimental data. Second, we introduce the scaled reduced pressure pr* to replace the previously used reduced pressure pr=p /pcr . We show that pr* is a function of the acentric factor only and can thus be readily determined from fluid property tables. It collapses both subcritical coexistence line and supercritical Widom line data over a wide range of species with acentric factors ranging from -0.38 (helium) to 0.34 (water), including alkanes up to n-hexane. By using pr*, the extended corresponding states principle can be applied within corresponding states principle formalism. Furthermore, pr* provides a theoretical foundation to compare Widom lines of different fluids.
Widom Lines in Binary Mixtures of Supercritical Fluids.
Raju, Muralikrishna; Banuti, Daniel T; Ma, Peter C; Ihme, Matthias
2017-06-08
Recent experiments on pure fluids have identified distinct liquid-like and gas-like regimes even under supercritical conditions. The supercritical liquid-gas transition is marked by maxima in response functions that define a line emanating from the critical point, referred to as Widom line. However, the structure of analogous state transitions in mixtures of supercritical fluids has not been determined, and it is not clear whether a Widom line can be identified for binary mixtures. Here, we present first evidence for the existence of multiple Widom lines in binary mixtures from molecular dynamics simulations. By considering mixtures of noble gases, we show that, depending on the phase behavior, mixtures transition from a liquid-like to a gas-like regime via distinctly different pathways, leading to phase relationships of surprising complexity and variety. Specifically, we show that miscible binary mixtures have behavior analogous to a pure fluid and the supercritical state space is characterized by a single liquid-gas transition. In contrast, immiscible binary mixture undergo a phase separation in which the clusters transition separately at different temperatures, resulting in multiple distinct Widom lines. The presence of this unique transition behavior emphasizes the complexity of the supercritical state to be expected in high-order mixtures of practical relevance.
NASA Astrophysics Data System (ADS)
Pipich, Vitaliy; Schwahn, Dietmar
2018-04-01
Thermal density fluctuations of supercritical CO2 were explored using small-angle neutron scattering (SANS), whose amplitude (susceptibility) and correlation length show the expected maximum at the Widom line. At low pressure, the susceptibility is in excellent agreement with the evaluated values on the basis of mass density measurements. At about 20 bar beyond the Widom line, SANS shows the formation of droplets accompanied by an enhanced number density of the supercritical fluid. The corresponding borderline is interpreted as a Frenkel line separating gas- and liquidlike regimes.
Pipich, Vitaliy; Schwahn, Dietmar
2018-04-06
Thermal density fluctuations of supercritical CO_{2} were explored using small-angle neutron scattering (SANS), whose amplitude (susceptibility) and correlation length show the expected maximum at the Widom line. At low pressure, the susceptibility is in excellent agreement with the evaluated values on the basis of mass density measurements. At about 20 bar beyond the Widom line, SANS shows the formation of droplets accompanied by an enhanced number density of the supercritical fluid. The corresponding borderline is interpreted as a Frenkel line separating gas- and liquidlike regimes.
Wang, Zhe; Liu, Kao-Hsiang; Le, Peisi; Li, Mingda; Chiang, Wei-Shan; Leão, Juscelino B; Copley, John R D; Tyagi, Madhusudan; Podlesnyak, Andrey; Kolesnikov, Alexander I; Mou, Chung-Yuan; Chen, Sow-Hsin
2014-06-13
The boson peak in deeply cooled water confined in nanopores is studied with inelastic neutron scattering. We show that in the (P, T) plane, the locus of the emergence of the boson peak is nearly parallel to the Widom line below ∼ 1600 bar. Above 1600 bar, the situation is different and from this difference the end pressure of the Widom line is estimated. The frequency and width of the boson peak correlate with the density of water, which suggests a method to distinguish the hypothetical "low-density liquid" and "high-density liquid" phases in deeply cooled water.
Infrared spectroscopic study of super-critical water across the Widom line
NASA Astrophysics Data System (ADS)
Samanta, Tuhin; Dutta, Rajesh; Biswas, Rajib; Bagchi, Biman
2018-06-01
When density is varied at a constant temperature just above the gas-liquid critical temperature, the system is found to exhibit large scale density fluctuations which are often rationalized in terms of crossing of a Widom line. We use the discrete variable representation (DVR) scheme to construct the spectroscopic maps for transition frequencies and transition dipoles, and obtain the infrared spectrum of the Osbnd H stretch in the said temperature-density region of the phase diagram. The infrared lineshape shows a crossover from Lorentzian to Gaussian as we approach the Widom line. The width of the lineshape displays a pronounced maximum.
Tourdot, Richard W; Ramakrishnan, N; Baumgart, Tobias; Radhakrishnan, Ravi
2015-10-01
We investigate the phenomenon of protein-induced tubulation of lipid bilayer membranes within a continuum framework using Monte Carlo simulations coupled with the Widom insertion technique to compute excess chemical potentials. Tubular morphologies are spontaneously formed when the density and the curvature-field strength of the membrane-bound proteins exceed their respective thresholds and this transition is marked by a sharp drop in the excess chemical potential. We find that the planar to tubular transition can be described by a micellar model and that the corresponding free-energy barrier increases with an increase in the curvature-field strength (i.e., of protein-membrane interactions) and also with an increase in membrane tension.
NASA Astrophysics Data System (ADS)
Bordonskii, G. S.; Gurulev, A. A.
2017-04-01
We have experimentally studied the thermal and microwave properties of a nanoporous medium (silica gel) with hydrogen-filled pores. On cooling down to about -45°C at atmospheric pressure, the system exhibited chemical transformations, a first-order phase transition with heat evolution, and a sharp change in the power of microwave radiation at 34 GHz transmitted through a sample. It is concluded that this point on the phase diagram corresponds to a point on the Widom line featuring sharp increase in fluctuations of the entropy and density of supercooled water formed during hydrogen interaction with the surface of pores in silica gel. These results confirm the existence of a second critical point of water, from which the Widom line originates.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Corradini, D.; Rovere, M.; Gallo, P., E-mail: gallop@fis.uniroma3.it
2015-09-21
In a previous study [Gallo et al., Nat. Commun. 5, 5806 (2014)], we have shown an important connection between thermodynamic and dynamical properties of water in the supercritical region. In particular, by analyzing the experimental viscosity and the diffusion coefficient obtained in simulations performed using the TIP4P/2005 model, we have found that the line of response function maxima in the one phase region, the Widom line, is connected to a crossover from a liquid-like to a gas-like behavior of the transport coefficients. This is in agreement with recent experiments concerning the dynamics of supercritical simple fluids. We here show howmore » different popular water models (TIP4P/2005, TIP4P, SPC/E, TIP5P, and TIP3P) perform in reproducing thermodynamic and dynamic experimental properties in the supercritical region. In particular, the comparison with experiments shows that all the analyzed models are able to qualitatively predict the dynamical crossover from a liquid-like to a gas-like behavior upon crossing the Widom line. Some of the models perform better in reproducing the pressure-temperature slope of the Widom line of supercritical water once a rigid shift of the phase diagram is applied to bring the critical points to coincide with the experimental ones.« less
NASA Astrophysics Data System (ADS)
Tennfors, Einar
2013-02-01
The present article is a critical comment on Widom and Larsens speculations concerning low-energy nuclear reactions (LENR) based on spontaneous collective motion of protons in a room temperature metallic hydride lattice producing oscillating electric fields that renormalize the electron self-energy, adding significantly to the effective electron mass and enabling production of low-energy neutrons. The frequency and mean proton displacement estimated on the basis of neutron scattering from protons in palladium and applied to the Widom and Larsens model of the proton oscillations yield an electron mass enhancement less than one percent, far below the threshold for the proposed neutron production and even farther below the mass enhancement obtained by Widom and Larsen assuming a high charge density. Neutrons are not stopped by the Coulomb barrier, but the energy required for the neutron production is not low.
Bonifácio, Rui P M F; Martins, Luís F G; McCabe, Clare; Filipe, Eduardo J M
2010-12-09
The solubility of xenon in liquid n-pentane and n-hexane has been studied experimentally, theoretically, and by computer simulation. Measurements of the solubility are reported for xenon + n-pentane as a function of temperature from 254 to 305 K. The uncertainty in the experimental data is less than 0.15%. The thermodynamic functions of solvation such as the standard Gibbs energy, enthalpy, and entropy of solvation have been calculated from Henry's law coefficients for xenon + n-pentane solutions and also for xenon + n-hexane, which were reported in previous work. The results provide a further example of the similarity between the xenon + n-alkane interaction and the n-alkane + n-alkane interactions. Using the SAFT-VR approach we were able to quantitatively predict the experimental solubility for xenon in n-pentane and semiquantitatively that of xenon in n-hexane using simple Lorentz-Berthelot combining rules to describe the unlikely interaction. Henry's constants at infinite dilution for xenon + n-pentane and xenon + n-hexane were also calculated by Monte Carlo simulation using a united atom force field to describe the n-alkane and the Widom test particle insertion method.
An extension of the Derrida-Lebowitz-Speer-Spohn equation
NASA Astrophysics Data System (ADS)
Bordenave, Charles; Germain, Pierre; Trogdon, Thomas
2015-12-01
We show how the derivation of the Derrida-Lebowitz-Speer-Spohn equation can be prolonged to obtain a new equation, generalizing the models obtained in the paper by these authors. We then investigate its properties from both an analytical and numerical perspective. Specifically, a numerical method is presented to approximate solutions of the prolonged equation. Using this method, we investigate the relationship between the solutions of the prolonged equation and the Tracy-Widom GOE distribution.
Methods for Melting Temperature Calculation
NASA Astrophysics Data System (ADS)
Hong, Qi-Jun
Melting temperature calculation has important applications in the theoretical study of phase diagrams and computational materials screenings. In this thesis, we present two new methods, i.e., the improved Widom's particle insertion method and the small-cell coexistence method, which we developed in order to capture melting temperatures both accurately and quickly. We propose a scheme that drastically improves the efficiency of Widom's particle insertion method by efficiently sampling cavities while calculating the integrals providing the chemical potentials of a physical system. This idea enables us to calculate chemical potentials of liquids directly from first-principles without the help of any reference system, which is necessary in the commonly used thermodynamic integration method. As an example, we apply our scheme, combined with the density functional formalism, to the calculation of the chemical potential of liquid copper. The calculated chemical potential is further used to locate the melting temperature. The calculated results closely agree with experiments. We propose the small-cell coexistence method based on the statistical analysis of small-size coexistence MD simulations. It eliminates the risk of a metastable superheated solid in the fast-heating method, while also significantly reducing the computer cost relative to the traditional large-scale coexistence method. Using empirical potentials, we validate the method and systematically study the finite-size effect on the calculated melting points. The method converges to the exact result in the limit of a large system size. An accuracy within 100 K in melting temperature is usually achieved when the simulation contains more than 100 atoms. DFT examples of Tantalum, high-pressure Sodium, and ionic material NaCl are shown to demonstrate the accuracy and flexibility of the method in its practical applications. The method serves as a promising approach for large-scale automated material screening in which the melting temperature is a design criterion. We present in detail two examples of refractory materials. First, we demonstrate how key material properties that provide guidance in the design of refractory materials can be accurately determined via ab initio thermodynamic calculations in conjunction with experimental techniques based on synchrotron X-ray diffraction and thermal analysis under laser-heated aerodynamic levitation. The properties considered include melting point, heat of fusion, heat capacity, thermal expansion coefficients, thermal stability, and sublattice disordering, as illustrated in a motivating example of lanthanum zirconate (La2Zr2O7). The close agreement with experiment in the known but structurally complex compound La2Zr 2O7 provides good indication that the computation methods described can be used within a computational screening framework to identify novel refractory materials. Second, we report an extensive investigation into the melting temperatures of the Hf-C and Hf-Ta-C systems using ab initio calculations. With melting points above 4000 K, hafnium carbide (HfC) and tantalum carbide (TaC) are among the most refractory binary compounds known to date. Their mixture, with a general formula TaxHf 1-xCy, is known to have a melting point of 4215 K at the composition Ta4HfC 5, which has long been considered as the highest melting temperature for any solid. Very few measurements of melting point in tantalum and hafnium carbides have been documented, because of the obvious experimental difficulties at extreme temperatures. The investigation lets us identify three major chemical factors that contribute to the high melting temperatures. Based on these three factors, we propose and explore a new class of materials, which, according to our ab initio calculations, may possess even higher melting temperatures than Ta-Hf-C. This example also demonstrates the feasibility of materials screening and discovery via ab initio calculations for the optimization of "higher-level" properties whose determination requires extensive sampling of atomic configuration space.
Fragile to strong crossover and Widom line in supercooled water: A comparative study
NASA Astrophysics Data System (ADS)
De Marzio, Margherita; Camisasca, Gaia; Rovere, Mauro; Gallo, Paola
2018-02-01
The aim of this paper is to discuss the relationship between the dynamics and thermodynamics of water in the supercooled region. Reviewed case studies comprehend bulk water simulated with the SPC/E, TIP4P and TIP4P/2005 potentials, water at protein interfaces, and water in solution with electrolytes. Upon supercooling, the fragile to strong crossover in the α-relaxation of water is found to occur when the Widom line emanating from the liquid-liquid critical point is crossed. This appears to be a general characteristic of supercooled water, not depending on the applied interaction potential and/or different local environments.
High-Throughput Characterization of Porous Materials Using Graphics Processing Units
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Jihan; Martin, Richard L.; Rübel, Oliver
We have developed a high-throughput graphics processing units (GPU) code that can characterize a large database of crystalline porous materials. In our algorithm, the GPU is utilized to accelerate energy grid calculations where the grid values represent interactions (i.e., Lennard-Jones + Coulomb potentials) between gas molecules (i.e., CHmore » $$_{4}$$ and CO$$_{2}$$) and material's framework atoms. Using a parallel flood fill CPU algorithm, inaccessible regions inside the framework structures are identified and blocked based on their energy profiles. Finally, we compute the Henry coefficients and heats of adsorption through statistical Widom insertion Monte Carlo moves in the domain restricted to the accessible space. The code offers significant speedup over a single core CPU code and allows us to characterize a set of porous materials at least an order of magnitude larger than ones considered in earlier studies. For structures selected from such a prescreening algorithm, full adsorption isotherms can be calculated by conducting multiple grand canonical Monte Carlo simulations concurrently within the GPU.« less
Mirzaeinia, Ali; Feyzi, Farzaneh; Hashemianzadeh, Seyed Majid
2017-12-07
Simple and accurate expressions are presented for the equation of state (EOS) and absolute Helmholtz free energy of a system composed of simple atomic particles interacting through the repulsive Lennard-Jones potential model in the fluid and solid phases. The introduced EOS has 17 and 22 coefficients for fluid and solid phases, respectively, which are regressed to the Monte Carlo (MC) simulation data over the reduced temperature range of 0.6≤T * ≤6.0 and the packing fraction range of 0.1 ≤ η ≤ 0.72. The average absolute relative percent deviation in fitting the EOS parameters to the MC data is 0.06 and 0.14 for the fluid and solid phases, respectively. The thermodynamic integration method is used to calculate the free energy using the MC simulation results. The Helmholtz free energy of the ideal gas is employed as the reference state for the fluid phase. For the solid phase, the values of the free energy at the reduced density equivalent to the close-packed of a hard sphere are used as the reference state. To check the validity of the predicted values of the Helmholtz free energy, the Widom particle insertion method and the Einstein crystal technique of Frenkel and Ladd are employed. The results obtained from the MC simulation approaches are well agreed to the EOS results, which show that the proposed model can reliably be utilized in the framework of thermodynamic theories.
NASA Astrophysics Data System (ADS)
Mirzaeinia, Ali; Feyzi, Farzaneh; Hashemianzadeh, Seyed Majid
2017-12-01
Simple and accurate expressions are presented for the equation of state (EOS) and absolute Helmholtz free energy of a system composed of simple atomic particles interacting through the repulsive Lennard-Jones potential model in the fluid and solid phases. The introduced EOS has 17 and 22 coefficients for fluid and solid phases, respectively, which are regressed to the Monte Carlo (MC) simulation data over the reduced temperature range of 0.6 ≤T*≤6.0 and the packing fraction range of 0.1 ≤ η ≤ 0.72. The average absolute relative percent deviation in fitting the EOS parameters to the MC data is 0.06 and 0.14 for the fluid and solid phases, respectively. The thermodynamic integration method is used to calculate the free energy using the MC simulation results. The Helmholtz free energy of the ideal gas is employed as the reference state for the fluid phase. For the solid phase, the values of the free energy at the reduced density equivalent to the close-packed of a hard sphere are used as the reference state. To check the validity of the predicted values of the Helmholtz free energy, the Widom particle insertion method and the Einstein crystal technique of Frenkel and Ladd are employed. The results obtained from the MC simulation approaches are well agreed to the EOS results, which show that the proposed model can reliably be utilized in the framework of thermodynamic theories.
Experimental Evidence of Low Density Liquid Water under Decompression
NASA Astrophysics Data System (ADS)
Shen, G.; Lin, C.; Sinogeikin, S. V.; Smith, J.
2017-12-01
Water is not only the most important substance for life, but also plays important roles in liquid science for its anomalous properties. It has been widely accepted that water's anomalies are not a result of simple thermal fluctuation, but are connected to the formation of various structural aggregates in the hydrogen bonding network. Among several proposed scenarios, one model of fluctuations between two different liquids has gradually gained traction. These two liquids are referred to as a low-density liquid (LDL) and a high-density liquid (HDL) with a coexistence line in the deeply supercooled regime at elevated pressure. The LDL-HDL transition ends with decreasing pressure at a liquid-liquid critical point (LLCP) with its Widom line extending to low pressures. Above the Widom line lies mostly HDL which is favored by entropy, while LDL, mostly lying below the Widom line, is favored by enthalpy in the tetrahedral hydrogen bonding network. The origin of water's anomalies can then be explained by the increase in structural fluctuations, as water is cooled down to deeply supercooled temperatures approaching the Widom line. Because both the LLCP and the LDL-HDL transition line lie in water's "no man's land" between the homogeneous nucleation temperature (TH, 232 K) and the crystallization temperature (TX, 150 K), the success of experiments exploring this region has been limited thus far. Using a rapid decompression technique integrated with in situ x-ray diffraction, we observe that a high-pressure ice phase transforms to a low-density noncrystalline (LDN) form upon rapid release of pressure at temperatures of 140-165K. The LDN subsequently crystallizes into ice-Ic through a diffusion-controlled process. The change in crystallization rate with temperature indicates that the LDN is a LDL with its tetrahedrally-coordinated network fully developed and clearly linked to low-density amorphous ices. The observation of the tetrahedral LDL supports the two-liquid model for water including the existence of a LLCP.
NASA Astrophysics Data System (ADS)
Errington, Jeffrey Richard
This work focuses on the development of intermolecular potential models for real fluids. United-atom models have been developed for both non-polar and polar fluids. The models have been optimized to the vapor-liquid coexistence properties. Histogram reweighting techniques were used to calculate phase behavior. The Hamiltonian scaling grand canonical Monte Carlo method was developed to enable the determination of thermodynamic properties of several related Hamiltonians from a single simulation. With this method, the phase behavior of variations of the Buckingham exponential-6 potential was determined. Reservoir grand canonical Monte Carlo simulations were developed to simulate molecules with complex architectures and/or stiff intramolecular constraints. The scheme is based on the creation of a reservoir of ideal chains from which structures are selected for insertion during a simulation. New intermolecular potential models have been developed for water, the n-alkane homologous series, benzene, cyclohexane, carbon dioxide, ammonia and methanol. The models utilize the Buckingham exponential-6 potential to model non-polar interactions and point charges to describe polar interactions. With the exception of water, the new models reproduce experimental saturated densities, vapor pressures and critical parameters to within a few percent. In the case of water, we found a set of parameters that describes the phase behavior better than other available point charge models while giving a reasonable description of the liquid structure. The mixture behavior of water-hydrocarbon mixtures has also been examined. The Henry's law constants of methane, ethane, benzene and cyclohexane in water were determined using Widom insertion and expanded ensemble techniques. In addition the high-pressure phase behavior of water-methane and water-ethane systems was studied using the Gibbs ensemble method. The results from this study indicate that it is possible to obtain a good description of the phase behavior of pure components using united-atom models. The mixture behavior of non-polar systems, including highly asymmetric components, was in good agreement with experiment. The calculations for the highly non-ideal water-hydrocarbon mixtures reproduced experimental behavior with varying degrees of success. The results indicate that multibody effects, such as polarizability, must be taken into account when modeling mixtures of polar and non-polar components.
Solid-liquid critical behavior of water in nanopores.
Mochizuki, Kenji; Koga, Kenichiro
2015-07-07
Nanoconfined liquid water can transform into low-dimensional ices whose crystalline structures are dissimilar to any bulk ices and whose melting point may significantly rise with reducing the pore size, as revealed by computer simulation and confirmed by experiment. One of the intriguing, and as yet unresolved, questions concerns the observation that the liquid water may transform into a low-dimensional ice either via a first-order phase change or without any discontinuity in thermodynamic and dynamic properties, which suggests the existence of solid-liquid critical points in this class of nanoconfined systems. Here we explore the phase behavior of a model of water in carbon nanotubes in the temperature-pressure-diameter space by molecular dynamics simulation and provide unambiguous evidence to support solid-liquid critical phenomena of nanoconfined water. Solid-liquid first-order phase boundaries are determined by tracing spontaneous phase separation at various temperatures. All of the boundaries eventually cease to exist at the critical points and there appear loci of response function maxima, or the Widom lines, extending to the supercritical region. The finite-size scaling analysis of the density distribution supports the presence of both first-order and continuous phase changes between solid and liquid. At around the Widom line, there are microscopic domains of two phases, and continuous solid-liquid phase changes occur in such a way that the domains of one phase grow and those of the other evanesce as the thermodynamic state departs from the Widom line.
NASA Astrophysics Data System (ADS)
Khawaja, Musab; Molinari, Nicola; Sutton, Adrian; Mostofi, Arash
In the oil and gas industry, elastomer seals play an important role in protecting sensitive monitoring equipment from contamination by gases - a problem that is exacerbated by the high pressures and temperatures found down-hole. The ability to predict and prevent such permeative failure has proved elusive to-date. Nitrile butadiene rubber (NBR) is a common choice of elastomer for seals due to its resistance to heat and fuels. In the conditions found in the well it readily absorbs small molecular weight gases. How this behaviour changes quantitatively for different gases as a function of temperature and pressure is not well-understood. In this work a series of fully atomistic simulations are performed to understand the effect of extreme conditions on gas solubility in NBR. Widom particle insertion is used to compute solubilities. The importance of sampling and allowing structural relaxation upon compression are highlighted, and qualitatively reasonable trends reproduced. Finally, while at STP it has previously been shown that the solubility of CO2 is higher than that of He in NBR, we observe that under the right circumstances it is possible to reverse this trend.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ni, Yicun; Skinner, J. L.
2016-06-07
Supercooled water exhibits many thermodynamic anomalies, and several scenarios have been proposed to interpret them, among which the liquid-liquid critical point (LLCP) hypothesis is the most commonly discussed. We investigated Widom lines and the LLCP of deeply supercooled water, by using molecular dynamics simulation with a newly reparameterized water model that explicitly includes three-body interactions. Seven isobars are studied from ambient pressure to 2.5 kbar, and Widom lines are identified by calculating maxima in the coefficient of thermal expansion and the isothermal compressibility (both with respect to temperature). From these data we estimate that the LLCP of the new watermore » model is at 180 K and 2.1 kbar. The oxygen radial distribution function is calculated along the 2 kbar isobar. It shows a steep change in the height of its second peak between 180 and 185 K, which indicates a transition between the high-density liquid and low-density liquid phases and which is consistent with the ascribed location of the critical point. The good agreement of the height of the second peak of the radial distribution function between simulation and experiment at 1 bar, as a function of temperature, supports the validity of the model. The location of the LLCP within the model is close to the kink in the experimental homogeneous nucleation line. We use existing experimental data to argue that the experimental LLCP is at 168 K and 1.95 kbar and speculate how this LLCP and its Widom line might be responsible for the kink in the homogeneous nucleation line.« less
Mallamace, Francesco; Corsaro, Carmelo; Mallamace, Domenico; ...
2015-12-05
The Boson peak (BP) of deeply cooled confined water is studied by using inelastic neutron scattering (INS) in a large interval of the (P, T) phase plane. By taking into account the different behavior of such a collective vibrational mode in both strong and fragile glasses as well as in glass-forming materials, we were able to determine the Widom line that characterizes supercooled bulk water within the frame of the liquid-liquid phase transition (LLPT) hypothesis. The peak frequency and width of the BP correlated with the water polymorphism of the LLPT scenario, allowing us to distinguish the “low-density liquid” (LDL)more » and “high-density liquid” (HDL) phases in deeply cooled bulk water.Moreover, the BP properties afford a further confirmation of theWidom line temperature T W as the (P, T) locus in which the local structure of water transforms from a predominately LDL form to a predominately HDL form.« less
NASA Astrophysics Data System (ADS)
Mallamace, Francesco; Corsaro, Carmelo; Mallamace, Domenico; Wang, Zhe; Chen, Sow-Hsin
2015-10-01
The Boson peak (BP) of deeply cooled confined water is studied by using inelastic neutron scattering (INS) in a large interval of the ( P, T) phase plane. By taking into account the different behavior of such a collective vibrational mode in both strong and fragile glasses as well as in glass-forming materials, we were able to determine the Widom line that characterizes supercooled bulk water within the frame of the liquid-liquid phase transition (LLPT) hypothesis. The peak frequency and width of the BP correlated with the water polymorphism of the LLPT scenario, allowing us to distinguish the "low-density liquid" (LDL) and "high-density liquid" (HDL) phases in deeply cooled bulk water.Moreover, the BP properties afford a further confirmation of theWidom line temperature T W as the ( P, T) locus in which the local structure of water transforms from a predominately LDL form to a predominately HDL form.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mallamace, Francesco; Corsaro, Carmelo; Mallamace, Domenico
The Boson peak (BP) of deeply cooled confined water is studied by using inelastic neutron scattering (INS) in a large interval of the (P, T) phase plane. By taking into account the different behavior of such a collective vibrational mode in both strong and fragile glasses as well as in glass-forming materials, we were able to determine the Widom line that characterizes supercooled bulk water within the frame of the liquid-liquid phase transition (LLPT) hypothesis. The peak frequency and width of the BP correlated with the water polymorphism of the LLPT scenario, allowing us to distinguish the “low-density liquid” (LDL)more » and “high-density liquid” (HDL) phases in deeply cooled bulk water.Moreover, the BP properties afford a further confirmation of theWidom line temperature T W as the (P, T) locus in which the local structure of water transforms from a predominately LDL form to a predominately HDL form.« less
Petit and grand ensemble Monte Carlo calculations of the thermodynamics of the lattice gas
DOE Office of Scientific and Technical Information (OSTI.GOV)
Murch, G.E.; Thorn, R.J.
1978-11-01
A direct Monte Carlo method for estimating the chemical potential in the petit canonical ensemble was applied to the simple cubic Ising-like lattice gas. The method is based on a simple relationship between the chemical potential and the potential energy distribution in a lattice gas at equilibrium as derived independently by Widom, and Jackson and Klein. Results are presented here for the chemical potential at various compositions and temperatures above and below the zero field ferromagnetic and antiferromagnetic critical points. The same lattice gas model was reconstructed in the form of a restricted grand canonical ensemble and results at severalmore » temperatures were compared with those from the petit canonical ensemble. The agreement was excellent in these cases.« less
Chemical potential of a test hard sphere of variable size in hard-sphere fluid mixtures.
Heyes, David M; Santos, Andrés
2018-06-07
A detailed comparison between the Boublík-Mansoori-Carnahan-Starling-Leland (BMCSL) equation of state of hard-sphere mixtures is made with Molecular Dynamics (MD) simulations of the same compositions. The Labík and Smith simulation technique [S. Labík and W. R. Smith, Mol. Simul. 12, 23-31 (1994)] was used to implement the Widom particle insertion method to calculate the excess chemical potential, βμ 0 ex , of a test particle of variable diameter, σ 0 , immersed in a hard-sphere fluid mixture with different compositions and values of the packing fraction, η. Use is made of the fact that the only polynomial representation of βμ 0 ex which is consistent with the limits σ 0 → 0 and σ 0 → ∞ has to be of the cubic form, i.e., c 0 (η)+c¯ 1 (η)σ 0 /M 1 +c¯ 2 (η)(σ 0 /M 1 ) 2 +c¯ 3 (η)(σ 0 /M 1 ) 3 , where M 1 is the first moment of the distribution. The first two coefficients, c 0 (η) and c¯ 1 (η), are known analytically, while c¯ 2 (η) and c¯ 3 (η) were obtained by fitting the MD data to this expression. This in turn provides a method to determine the excess free energy per particle, βa ex , in terms of c¯ 2 , c¯ 3 , and the compressibility factor, Z. Very good agreement between the BMCSL formulas and the MD data is found for βμ 0 ex , Z, and βa ex for binary mixtures and continuous particle size distributions with the top-hat analytic form. However, the BMCSL theory typically slightly underestimates the simulation values, especially for Z, differences which the Boublík-Carnahan-Starling-Kolafa formulas and an interpolation between two Percus-Yevick routes capture well in different ranges of the system parameter space.
Chemical potential of a test hard sphere of variable size in hard-sphere fluid mixtures
NASA Astrophysics Data System (ADS)
Heyes, David M.; Santos, Andrés
2018-06-01
A detailed comparison between the Boublík-Mansoori-Carnahan-Starling-Leland (BMCSL) equation of state of hard-sphere mixtures is made with Molecular Dynamics (MD) simulations of the same compositions. The Labík and Smith simulation technique [S. Labík and W. R. Smith, Mol. Simul. 12, 23-31 (1994)] was used to implement the Widom particle insertion method to calculate the excess chemical potential, β μ0ex, of a test particle of variable diameter, σ0, immersed in a hard-sphere fluid mixture with different compositions and values of the packing fraction, η. Use is made of the fact that the only polynomial representation of β μ0ex which is consistent with the limits σ0 → 0 and σ0 → ∞ has to be of the cubic form, i.e., c0(η ) +c¯ 1(η ) σ0/M1+c¯ 2(η ) (σ0/M1 ) 2+c¯ 3(η ) (σ0/M1 ) 3, where M1 is the first moment of the distribution. The first two coefficients, c0(η) and c¯ 1(η ) , are known analytically, while c¯ 2(η ) and c¯ 3(η ) were obtained by fitting the MD data to this expression. This in turn provides a method to determine the excess free energy per particle, βaex, in terms of c¯ 2, c¯ 3, and the compressibility factor, Z. Very good agreement between the BMCSL formulas and the MD data is found for β μ0ex, Z, and βaex for binary mixtures and continuous particle size distributions with the top-hat analytic form. However, the BMCSL theory typically slightly underestimates the simulation values, especially for Z, differences which the Boublík-Carnahan-Starling-Kolafa formulas and an interpolation between two Percus-Yevick routes capture well in different ranges of the system parameter space.
ERIC Educational Resources Information Center
Ryan, Joseph P.; Testa, Mark F.; Zhai, Fuhua
2008-01-01
Juvenile delinquency remains a significant problem for child welfare systems throughout the United States. Victims of child abuse and neglect are more likely relative to children in the general population to engage in delinquency (Ryan & Testa, 2005; Widom, 1989). Although the magnitude of this relationship is not fully understood (Zingraff,…
A globally accurate theory for a class of binary mixture models
NASA Astrophysics Data System (ADS)
Dickman, Adriana G.; Stell, G.
The self-consistent Ornstein-Zernike approximation results for the 3D Ising model are used to obtain phase diagrams for binary mixtures described by decorated models, yielding the plait point, binodals, and closed-loop coexistence curves for the models proposed by Widom, Clark, Neece, and Wheeler. The results are in good agreement with series expansions and experiments.
Communication: Diffusion constant in supercooled water as the Widom line is crossed in no man's land
NASA Astrophysics Data System (ADS)
Ni, Yicun; Hestand, Nicholas J.; Skinner, J. L.
2018-05-01
According to the liquid-liquid critical point (LLCP) hypothesis, there are two distinct phases of supercooled liquid water, namely, high-density liquid and low-density liquid, separated by a coexistence line that terminates in an LLCP. If the LLCP is real, it is located within No Man's Land (NML), the region of the metastable phase diagram that is difficult to access using conventional experimental techniques due to rapid homogeneous nucleation to the crystal. However, a recent ingenious experiment has enabled measurement of the diffusion constant deep inside NML. In the current communication, these recent measurements are compared, with good agreement, to the diffusion constant of E3B3 water, a classical water model that explicitly includes three-body interactions. The behavior of the diffusion constant as the system crosses the Widom line (the extension of the liquid-liquid coexistence line into the one-phase region) is analyzed to derive information about the presence and location of the LLCP. Calculations over a wide range of temperatures and pressures show that the new experimental measurements are consistent with an LLCP having a critical pressure of over 0.6 kbar.
A new variant of a scaling hypothesis and a fundamental equation of state based on it
NASA Astrophysics Data System (ADS)
Kudryavtseva, I. V.; Rykov, V. A.; Rykov, S. V.; Ustyuzhanin, E. E.
2018-01-01
This paper deals with a fundamental equation of state (FEOS) for substances. We have suggested a new method. It allows constructing FEOS that is based on the scaling theory of critical phenomena and describes thermodynamic properties related to liquid and gas phases of a substance in a wide range of the pressures and temperatures. In the framework of the methodological approach, we have provided: (i) a transition of FEOS in a virial equation of state in the low density region; (ii) a transition of FEOS in a Widom equation of state in the critical region. The method has been tested on the example of FEOS of R218. The area of applicability of FEOS is 0 < ρ/ρ c < 3.2 in the density and 133 < T < 440 K in the temperature. We have compared FEOS with some equations of state and discussed the results.
Molecular Simulations of Adsorption and Diffusion in Silicalite.
NASA Astrophysics Data System (ADS)
Snurr, Randall Quentin
The adsorption and diffusion of hydrocarbons in the zeolite silicalite have been studied using molecular simulations. The simulations use an atomistic description of zeolite/sorbate interactions and are based on principles of statistical mechanics. Emphasis was placed on developing new simulation techniques to allow complex systems relevant to industrial applications in catalysis and separations processes to be studied. Adsorption isotherms and heats of sorption for methane in silicalite were calculated from grand canonical Monte Carlo (GCMC) simulations and also from molecular dynamics (MD) simulations accompanied by Widom test particle insertions. Good agreement with experimental data from the literature was found. The adsorption thermodynamics of aromatic species in silicalite at low loading was predicted by direct evaluation of the configurational integrals. Good agreement with experiment was obtained for the Henry's constants and the heats of adsorption. Molecules were predicted to be localized in the channel intersections at low loading. At higher loading, conventional GCMC simulations were found to be infeasible. Several variations of the GCMC technique were developed incorporating biased insertion moves. These new techniques are much more efficient than conventional GCMC and allow for the prediction of adsorption isotherms of tightly-fitting aromatic molecules in silicalite. Our simulations when combined with experimental evidence of a phase change in the zeolite structure at intermediate loading provide an explanation of the characteristic steps seen in the experimental isotherms. A hierarchical atomistic/lattice model for studying these systems was also developed. The hierarchical model is more than an order of magnitude more efficient computationally than direct atomistic simulation. Diffusion of benzene in silicalite was studied using transition-state theory (TST). Such an approach overcomes the time-scale limitations of using MD simulations for studying sorbate dynamics. Predicted diffusion coefficients were found to be too low compared to experiment. This was attributed to the assumption of a rigid zeolite structure in the calculations and the use of a harmonic approximation for calculating the TST rate constants. Details of sorbate motion were also investigated.
A Short Note on the Scaling Function Constant Problem in the Two-Dimensional Ising Model
NASA Astrophysics Data System (ADS)
Bothner, Thomas
2018-02-01
We provide a simple derivation of the constant factor in the short-distance asymptotics of the tau-function associated with the 2-point function of the two-dimensional Ising model. This factor was first computed by Tracy (Commun Math Phys 142:297-311, 1991) via an exponential series expansion of the correlation function. Further simplifications in the analysis are due to Tracy and Widom (Commun Math Phys 190:697-721, 1998) using Fredholm determinant representations of the correlation function and Wiener-Hopf approximation results for the underlying resolvent operator. Our method relies on an action integral representation of the tau-function and asymptotic results for the underlying Painlevé-III transcendent from McCoy et al. (J Math Phys 18:1058-1092, 1977).
Bansal, Artee; Chapman, Walter G; Asthagiri, D
2017-09-28
We derive an expression for the chemical potential of an associating solute in a solvent relative to the value in a reference fluid using the quasichemical organization of the potential distribution theorem. The fraction of times the solute is not associated with the solvent, the monomer fraction, is expressed in terms of (a) the statistics of occupancy of the solvent around the solute in the reference fluid and (b) the Widom factors that arise because of turning on solute-solvent association. Assuming pair-additivity, we expand the Widom factor into a product of Mayer f-functions and the resulting expression is rearranged to reveal a form of the monomer fraction that is analogous to that used within the statistical associating fluid theory (SAFT). The present formulation avoids all graph-theoretic arguments and provides a fresh, more intuitive, perspective on Wertheim's theory and SAFT. Importantly, multi-body effects are transparently incorporated into the very foundations of the theory. We illustrate the generality of the present approach by considering examples of multiple solvent association to a colloid solute with bonding domains that range from a small patch on the sphere to a Janus particle to a solute whose entire surface is available for association.
NASA Astrophysics Data System (ADS)
Bansal, Artee; Chapman, Walter G.; Asthagiri, D.
2017-09-01
We derive an expression for the chemical potential of an associating solute in a solvent relative to the value in a reference fluid using the quasichemical organization of the potential distribution theorem. The fraction of times the solute is not associated with the solvent, the monomer fraction, is expressed in terms of (a) the statistics of occupancy of the solvent around the solute in the reference fluid and (b) the Widom factors that arise because of turning on solute-solvent association. Assuming pair-additivity, we expand the Widom factor into a product of Mayer f-functions and the resulting expression is rearranged to reveal a form of the monomer fraction that is analogous to that used within the statistical associating fluid theory (SAFT). The present formulation avoids all graph-theoretic arguments and provides a fresh, more intuitive, perspective on Wertheim's theory and SAFT. Importantly, multi-body effects are transparently incorporated into the very foundations of the theory. We illustrate the generality of the present approach by considering examples of multiple solvent association to a colloid solute with bonding domains that range from a small patch on the sphere to a Janus particle to a solute whose entire surface is available for association.
1991-02-01
1977; Robb 1982; Andelman et al. 1987; Widom 1984, 1986; De Gennes and Taupin 1982; Talmon and Prager 1977, 1978, 1982; Scriven 1976, 1977; Di Meglio...Dvolaitzky, and Taupin 1985; Chen et al. 1986; Borkovec et al. 1988; Lindman et al. 1980; Lichterfeld, Schemling, and Strey 1986; Kaler et al. 1983...rigidity of the surfactant film is reduced (Andelman et al. 1987; De Gennes and Taupin 1982; Di Meglio, Dvolaitzky, and Taupin 1985) and the surface
Critical behavior near the ferromagnetic phase transition in double perovskite Nd2NiMnO6
NASA Astrophysics Data System (ADS)
Ali, Anzar; Sharma, G.; Singh, Yogesh
2018-05-01
The knowledge of critical exponents plays a crucial role in trying to understand the interaction mechanism near a phase transition. In this report, we present a detailed study of the critical behaviour near the ferromagnetic (FM) transition (TC ˜ 193 K) in Nd2NiMnO6 using the temperature and magnetic field dependent isothermal magnetisation measurements. We used various analysis methods such as Arrott plot, modified Arrott plot, and Kouvel-Fisher plot to estimate the critical parameters. The magnetic critical parameters β = 0.49±0.02, γ = 1.05±0.04 and critical isothermal parameter δ = 3.05±0.02 are in excellent agreement with Widom scaling. The critical parameters analysis emphasizes that mean field interaction is the mechanism driving the FM transition in Nd2NiMnO6.
To cut or not to cut? Assessing the modular structure of brain networks.
Chang, Yu-Teng; Pantazis, Dimitrios; Leahy, Richard M
2014-05-01
A wealth of methods has been developed to identify natural divisions of brain networks into groups or modules, with one of the most prominent being modularity. Compared with the popularity of methods to detect community structure, only a few methods exist to statistically control for spurious modules, relying almost exclusively on resampling techniques. It is well known that even random networks can exhibit high modularity because of incidental concentration of edges, even though they have no underlying organizational structure. Consequently, interpretation of community structure is confounded by the lack of principled and computationally tractable approaches to statistically control for spurious modules. In this paper we show that the modularity of random networks follows a transformed version of the Tracy-Widom distribution, providing for the first time a link between module detection and random matrix theory. We compute parametric formulas for the distribution of modularity for random networks as a function of network size and edge variance, and show that we can efficiently control for false positives in brain and other real-world networks. Copyright © 2014 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hayashi, A.; Hashimoto, T.; Horibe, M.
The quantum color coding scheme proposed by Korff and Kempe [e-print quant-ph/0405086] is easily extended so that the color coding quantum system is allowed to be entangled with an extra auxiliary quantum system. It is shown that in the extended scheme we need only {approx}2{radical}(N) quantum colors to order N objects in large N limit, whereas {approx}N/e quantum colors are required in the original nonextended version. The maximum success probability has asymptotics expressed by the Tracy-Widom distribution of the largest eigenvalue of a random Gaussian unitary ensemble (GUE) matrix.
Finite-size effects in the short-time height distribution of the Kardar-Parisi-Zhang equation
NASA Astrophysics Data System (ADS)
Smith, Naftali R.; Meerson, Baruch; Sasorov, Pavel
2018-02-01
We use the optimal fluctuation method to evaluate the short-time probability distribution P(H, L, t) of height at a single point, H=h(x=0, t) , of the evolving Kardar-Parisi-Zhang (KPZ) interface h(x, t) on a ring of length 2L. The process starts from a flat interface. At short times typical (small) height fluctuations are unaffected by the KPZ nonlinearity and belong to the Edwards-Wilkinson universality class. The nonlinearity, however, strongly affects the (asymmetric) tails of P(H) . At large L/\\sqrt{t} the faster-decaying tail has a double structure: it is L-independent, -\\lnP˜≤ft\\vert H\\right\\vert 5/2/t1/2 , at intermediately large \\vert H\\vert , and L-dependent, -\\lnP˜ ≤ft\\vert H\\right\\vert 2L/t , at very large \\vert H\\vert . The transition between these two regimes is sharp and, in the large L/\\sqrt{t} limit, behaves as a fractional-order phase transition. The transition point H=Hc+ depends on L/\\sqrt{t} . At small L/\\sqrt{t} , the double structure of the faster tail disappears, and only the very large-H tail, -\\lnP˜ ≤ft\\vert H\\right\\vert 2L/t , is observed. The slower-decaying tail does not show any L-dependence at large L/\\sqrt{t} , where it coincides with the slower tail of the GOE Tracy-Widom distribution. At small L/\\sqrt{t} this tail also has a double structure. The transition between the two regimes occurs at a value of height H=Hc- which depends on L/\\sqrt{t} . At L/\\sqrt{t} \\to 0 the transition behaves as a mean-field-like second-order phase transition. At \\vert H\\vert <\\vert H_c-\\vert the slower tail behaves as -\\lnP˜ ≤ft\\vert H\\right\\vert 2L/t , whereas at \\vert H\\vert >\\vert H_c-\\vert it coincides with the slower tail of the GOE Tracy-Widom distribution.
Kim, Sung Jae; Kim, Sung Hwan; Kim, Young Hwan; Chun, Yong Min
2015-01-01
The authors have observed a failure to achieve secure fixation in elderly patients when inserting a half-pin at the anteromedial surface of the tibia. The purpose of this study was to compare two methods for inserting a half-pin at tibia diaphysis in elderly patients. Twenty cadaveric tibias were divided into Group C or V. A half-pin was inserted into the tibias of Group C via the conventional method, from the anteromedial surface to the interosseous border of the tibia diaphysis, and into the tibias of Group V via the vertical method, from the anterior border to the posterior surface at the same level. The maximum insertion torque was measured during the bicortical insertion with a torque driver. The thickness of the cortex was measured by micro-computed tomography. The relationship between the thickness of the cortex engaged and the insertion torque was investigated. The maximum insertion torque and the thickness of the cortex were significantly higher in Group V than Group C. Both groups exhibited a statistically significant linear correlation between torque and thickness by Spearman's rank correlation analysis. Half-pins inserted by the vertical method achieved purchase of more cortex than those inserted by the conventional method. Considering that cortical thickness and insertion torque in Group V were significantly greater than those in Group C, we suggest that the vertical method of half-pin insertion may be an alternative to the conventional method in elderly patients.
Critical scaling analysis for displacive-type organic ferroelectrics around ferroelectric transition
NASA Astrophysics Data System (ADS)
Ding, L. J.
2017-04-01
The critical scaling properties of displacive-type organic ferroelectrics, in which the ferroelectric-paraelectric transition is induced by spin-Peierls instability, are investigated by Green's function theory through the modified Arrott plot, critical isothermal and electrocaloric effect (ECE) analysis around the transition temperature TC. It is shown that the electric entropy change - ΔS follows a power-law dependence of electric field E : - ΔS ∼En with n satisfying the Franco equation n(TC) = 1 +(β - 1) /(β + γ) = 0.618, wherein the obtained critical exponents β = 0.440 and γ = 1.030 are not only corroborated by Kouvel-Fisher method, but also confirm the Widom critical relation δ = 1 + γ / β. The self-consistency and reliability of the obtained critical exponents are further verified by the scaling equations. Additionally, a universal curve of - ΔS is constructed with rescaling temperature and electric field, so that one can extrapolate the ECE in a certain temperature and electric field range, which would be helpful in designing controlled electric refrigeration devices.
Method Of Wire Insertion For Electric Machine Stators
Brown, David L; Stabel, Gerald R; Lawrence, Robert Anthony
2005-02-08
A method of inserting coils in slots of a stator is provided. The method includes interleaving a first set of first phase windings and a first set of second phase windings on an insertion tool. The method also includes activating the insertion tool to radially insert the first set of first phase windings and the first set of second phase windings in the slots of the stator. In one embodiment, interleaving the first set of first phase windings and the first set of second phase windings on the insertion tool includes forming the first set of first phase windings in first phase openings defined in the insertion tool, and forming the first set of second phase windings in second phase openings defined in the insertion tool.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mendl, Christian B.; Spohn, Herbert
The nonequilibrium dynamics of anharmonic chains is studied by imposing an initial domain-wall state, in which the two half lattices are prepared in equilibrium with distinct parameters. Here, we analyse the Riemann problem for the corresponding Euler equations and, in specific cases, compare with molecular dynamics. Additionally, the fluctuations of time-integrated currents are investigated. In analogy with the KPZ equation, their typical fluctuations should be of size t 1/3 and have a Tracy–Widom GUE distributed amplitude. The proper extension to anharmonic chains is explained and tested through molecular dynamics. Our results are calibrated against the stochastic LeRoux lattice gas.
Solid-like features in dense vapors near the fluid critical point
NASA Astrophysics Data System (ADS)
Ruppeiner, George; Dyjack, Nathan; McAloon, Abigail; Stoops, Jerry
2017-06-01
The phase diagram (pressure versus temperature) of the pure fluid is typically envisioned as being featureless apart from the presence of the liquid-vapor coexistence curve terminating at the critical point. However, a number of recent authors have proposed that this simple picture misses important features, such as the Widom line, the Fisher-Widom line, and the Frenkel line. In our paper, we discuss another way of augmenting the pure fluid phase diagram, lines of zero thermodynamic curvature R = 0 separating regimes of fluid solid-like behavior (R > 0) from gas-like or liquid-like behavior (R < 0). We systematically evaluate R for the 121 pure fluids in the NIST/REFPROP (version 9.1) fluid database near the saturated vapor line from the triple point to the critical point. Our specific goal was to identify regions of positive R abutting the saturated vapor line ("feature D"). We found the following: (i) 97/121 of the NIST/REFPROP fluids have feature D. (ii) The presence and character of feature D correlates with molecular complexity, taken to be the number of atoms Q per molecule. (iii) The solid-like properties of feature D might be attributable to a mesoscopic model based on correlations among coordinated spinning molecules, a model that might be testable with computer simulations. (iv) There are a number of correlations between thermodynamic quantities, including the acentric factor ω , but we found little explicit correlation between ω and the shape of a molecule. (v) Feature D seriously constrains the size of the asymptotic fluid critical point regime, possibly resolving a long-standing mystery about why these are so small. (vi) Feature D correlates roughly with regimes of anomalous sound propagation.
Alternative method for predicting optimal insertion depth of the laryngeal tube in children.
Kim, J T; Jeon, S Y; Kim, C S; Kim, S D; Kim, H S
2007-11-01
Little information is available about the accuracy of the teeth mark on the laryngeal tube (LT) as a guide to correct placement in children. The aim of this crossover study was to evaluate three methods for optimal insertion depth of the size (#) 2 tube in children weighing 12-25 kg. In 24 children, the LT #2 was consecutively inserted by three different methods: (A) until the thick teeth mark on the tube was aligned with the upper incisors, (B) until resistance was felt, and (C) by inserting to a depth, previously measured, of the curved distance between the cricoid cartilage and the upper incisor. In each case, the depth of insertion, the degree of effective ventilation, the presence of leakage, and the fibreoptic view were assessed. Insertion based on the teeth mark led to a shorter insertion depth and a greater incidence of inadequate ventilation compared with the other two methods. There was no difference in the adequacy of ventilation between methods B and C. The vocal cords were more easily identified with methods B (62.5%) and C (75%) than with method A (12.5%). Insertion of the LT #2 aligned with the teeth mark can result in a shallow insertion depth and inadequate ventilation. The measured distance from the cricoid cartilage to the upper incisor offers alternative guidance for correct LT insertion.
Comparison of success rates of orthodontic mini-screws by the insertion method.
Kim, Jung Suk; Choi, Seong Hwan; Cha, Sang Kwon; Kim, Jang Han; Lee, Hwa Jin; Yeom, Sang Seon; Hwang, Chung Ju
2012-10-01
The aim of this study was to compare the success rates of the manual and motor-driven mini-screw insertion methods according to age, gender, length of mini-screws, and insertion sites. We retrospectively reviewed 429 orthodontic mini-screw placements in 286 patients (102 in men and 327 in women) between 2005 and 2010 at private practice. Age, gender, mini-screw length, and insertion site were cross-tabulated against the insertion methods. The Cochran-Mantel-Haenszel test was performed to compare the success rates of the 2 insertion methods. The motor-driven method was used for 228 mini-screws and the manual method for the remaining 201 mini-screws. The success rates were similar in both men and women irrespective of the insertion method used. With respect to mini-screw length, no difference in success rates was found between motor and hand drivers for the 6-mm-long mini-screws (68.1% and 69.5% with the engine driver and hand driver, respectively). However, the 8-mm-long mini-screws exhibited significantly higher success rates (90.4%, p < 0.01) than did the 6-mm-long mini-screws when placed with the engine driver. The overall success rate was also significantly higher in the maxilla (p < 0.05) when the engine driver was used. Success rates were similar among all age groups regardless of the insertion method used. Taken together, the motor-driven insertion method can be helpful to get a higher success rate of orthodontic mini-screw placement.
Anomalous behavior of nonlinear refractive indexes of CO2 and Xe in supercritical states.
Mareev, Evgenii; Aleshkevich, Victor; Potemkin, Fedor; Bagratashvili, Victor; Minaev, Nikita; Gordienko, Vyacheslav
2018-05-14
Direct measurement of pressure dependent nonlinear refractive index of CO 2 and Xe in subcritical and supercritical states are reported. In the vicinity of the ridge (or the Widom line), corresponding to the maximum density fluctuations, the nonlinear refractive index reaches a maximum value (up to 4.8*10 -20 m 2 /W in CO 2 and 3.5*10 -20 m 2 /W in Xe). Anomalous behavior of the nonlinear refractive index in the vicinity of a ridge is caused by the cluster formation. That corresponds to the results of our theoretical assumption based on the modified Langevin theory.
Shocks, Rarefaction Waves, and Current Fluctuations for Anharmonic Chains
Mendl, Christian B.; Spohn, Herbert
2016-10-04
The nonequilibrium dynamics of anharmonic chains is studied by imposing an initial domain-wall state, in which the two half lattices are prepared in equilibrium with distinct parameters. Here, we analyse the Riemann problem for the corresponding Euler equations and, in specific cases, compare with molecular dynamics. Additionally, the fluctuations of time-integrated currents are investigated. In analogy with the KPZ equation, their typical fluctuations should be of size t 1/3 and have a Tracy–Widom GUE distributed amplitude. The proper extension to anharmonic chains is explained and tested through molecular dynamics. Our results are calibrated against the stochastic LeRoux lattice gas.
Ouchi, Kentaro; Sugiyama, Kazuna
2016-04-01
Incorrect endobronchial placement of the tracheal tube can lead to serious complications. Hence, it is necessary to determine the accuracy of tracheal tube positioning. Markers are included on tracheal tubes, in the process of their manufacture, as indicators of approximate intubation depth. In addition, continuous chest auscultation has been used for determining the proper position of the tube. We examined insertion depth using the cuff depth and continuous chest auscultation method (CC method), compared with insertion depth determined by the marker method, to assess the accuracy of these methods. After induction of anesthesia, tracheal intubation was performed in each patient. In the CC method, the depth of tube insertion was measured when the cuff had passed through the glottis, and again when breath sounds changed in quality; the depth of tube insertion was determined from these values. In the marker method, the depth of tube insertion was measured and determined when the marker of the tube had reached the glottis, using insertion depth according to the marker as an index. Insertion depth by the marker method was 26.6 ± 1.2 cm and by the CC method was 28.0 ± 1.2 cm (P < 0.0001). The CC method indicated a significantly greater depth than the marker method. This study determined the safe range of tracheal tube placement. Tube positions determined by the CC method were about 1 cm deeper than those determined by the marker. This information is important to prevent accidental one-lung ventilation and accidental extubation. UMIN No. UMIN000011375.
Zhao, Feng; Wang, Chuan; Fan, Yubo
2015-01-01
Wear of polyethylene (PE) tibial inserts is a significant cause of implant failure of total knee arthroplasty (TKA). PE inserts wear measurement and evaluation is the key in TKA researches. There are many methods to measure insert wear. Qualitative methods such as observation are used to determine the wear and its type. Quantitative methods such as gravimetric analysis, coordinate measuring machines (CMM) and micro-computed tomography (micro-CT) are used to measure the mass, volume and geometry of wear. In this paper, the principle, characteristics and research progress of main insert wear evaluation method were introduced and the problems and disadvantages were analyzed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Yu; Petrovic, C.
Some critical properties of the single-crystalline semiconducting ferromagnet Cr 2 Ge 2 Te 6 were investigated by bulk dc magnetization around the paramagnetic to ferromagnetic phase transition. Critical exponents β = 0.200 ± 0.003 with a critical temperature T c = 62.65 ± 0.07 K and γ = 1.28 ± 0.03 with T c = 62.75 ± 0.06 K are obtained by the Kouvel-Fisher method whereas δ = 7.96 ± 0.01 is obtained by a critical isotherm analysis at T c = 62.7 K. These critical exponents obey the Widom scaling relation δ = 1 + γ / β ,more » indicating self-consistency of the obtained values. Furthermore, with these critical exponents the isotherm M ( H ) curves below and above the critical temperatures collapse into two independent universal branches, obeying the single scaling equation m = f ± ( h ) , where m and h are renormalized magnetization and field, respectively. The determined exponents match well with those calculated from the results of the renormalization group approach for a two-dimensional Ising system coupled with a long-range interaction between spins decaying as J ( r ) ≈ r - ( d + σ ) with σ = 1.52 .« less
Methods for Using Durable Adhesively Bonded Joints for Sandwich Structures
NASA Technical Reports Server (NTRS)
Smeltzer, Stanley S., III (Inventor); Lundgren, Eric C. (Inventor)
2016-01-01
Systems, methods, and apparatus for increasing durability of adhesively bonded joints in a sandwich structure. Such systems, methods, and apparatus includes an first face sheet and an second face sheet as well as an insert structure, the insert structure having a first insert face sheet, a second insert face sheet, and an insert core material. In addition, sandwich core material is arranged between the first face sheet and the second face sheet. A primary bondline may be coupled to the face sheet(s) and the splice. Further, systems, methods, and apparatus of the present disclosure advantageously reduce the load, provide a redundant path, reduce structural fatigue, and/or increase fatigue life.
Systems, Apparatuses, and Methods for Using Durable Adhesively Bonded Joints for Sandwich Structures
NASA Technical Reports Server (NTRS)
Smeltzer, III, Stanley S. (Inventor); Lundgren, Eric C. (Inventor)
2014-01-01
Systems, methods, and apparatus for increasing durability of adhesively bonded joints in a sandwich structure. Such systems, methods, and apparatus includes an first face sheet and an second face sheet as well as an insert structure, the insert structure having a first insert face sheet, a second insert face sheet, and an insert core material. In addition, sandwich core material is arranged between the first face sheet and the second face sheet. A primary bondline may be coupled to the face sheet(s) and the splice. Further, systems, methods, and apparatus of the present disclosure advantageously reduce the load, provide a redundant path, reduce structural fatigue, and/or increase fatigue life.
Lu, Wenke; Zhu, Changchun
2011-11-01
The objective of this research was to investigate the possibility of compensating for the insertion losses of the wavelet inverse-transform processors using SAW devices. The motivation for this work was prompted by the processors which are of large insertion losses. In this paper, the insertion losses are the key problem of the wavelet inverse-transform processors using SAW devices. A novel compensation method of the insertion losses is achieved in this study. When the output ends of the wavelet inverse-transform processors are respectively connected to the amplifiers, their insertion losses can be compensated for. The bandwidths of the amplifiers and their adjustment method are also given in this paper. © 2011 American Institute of Physics
Sharifi, Maryam; Ghassemi, Amirreza; Bayani, Shahin
2015-01-01
Success of orthodontic miniscrews in providing stable anchorage is dependent on their stability. The purpose of this study was to assess the effect of insertion method and postinsertion time interval on the removal torque of miniscrews as an indicator of their stability. Seventy-two miniscrews (Jeil Medical) were inserted into the femoral bones of three male German Shepherd dogs and assigned to nine groups of eight miniscrews. Three insertion methods, including hand-driven, motor-driven with 5.0-Ncm insertion torque, and motor-driven with 20.0-Ncm insertion torque, were tested. Three time intervals of 0, 2, and 6 weeks between miniscrew insertion and removal were tested as well. Removal torque values were measured in newton centimeters by a removal torque tester (IMADA). Data were analyzed by one-way analysis of variance (ANOVA) followed by the Bonferroni post hoc test at a .05 level of significance. A miniscrew survival rate of 93% was observed in this study. The highest mean value of removal torque among the three postinsertion intervals (2.4 ± 0.59 Ncm) was obtained immediately after miniscrew insertion with a statistically significant difference from the other two time intervals (P < .001). Insertion were observed in this regard (P = .46). The stability of miniscrews was not affected by the insertion method. However, of the postinsertion time intervals, the highest removal torque values were obtained immediately after insertion.
Kardar-Parisi-Zhang universality in the phase distributions of one-dimensional exciton-polaritons
NASA Astrophysics Data System (ADS)
Squizzato, Davide; Canet, Léonie; Minguzzi, Anna
2018-05-01
Exciton-polaritons under driven-dissipative conditions exhibit a condensation transition that belongs to a different universality class from that of equilibrium Bose-Einstein condensates. By numerically solving the generalized Gross-Pitaevskii equation with realistic experimental parameters, we show that one-dimensional exciton-polaritons display fine features of Kardar-Parisi-Zhang (KPZ) dynamics. Beyond the scaling exponents, we show that their phase distribution follows the Tracy-Widom form predicted for KPZ growing interfaces. We moreover evidence a crossover to the stationary Baik-Rains statistics. We finally show that these features are unaffected on a certain timescale by the presence of a smooth disorder often present in experimental setups.
Exact Extremal Statistics in the Classical 1D Coulomb Gas
NASA Astrophysics Data System (ADS)
Dhar, Abhishek; Kundu, Anupam; Majumdar, Satya N.; Sabhapandit, Sanjib; Schehr, Grégory
2017-08-01
We consider a one-dimensional classical Coulomb gas of N -like charges in a harmonic potential—also known as the one-dimensional one-component plasma. We compute, analytically, the probability distribution of the position xmax of the rightmost charge in the limit of large N . We show that the typical fluctuations of xmax around its mean are described by a nontrivial scaling function, with asymmetric tails. This distribution is different from the Tracy-Widom distribution of xmax for Dyson's log gas. We also compute the large deviation functions of xmax explicitly and show that the system exhibits a third-order phase transition, as in the log gas. Our theoretical predictions are verified numerically.
Quantifying electrical impacts on redundant wire insertion in 7nm unidirectional designs
NASA Astrophysics Data System (ADS)
Mohyeldin, Ahmed; Schroeder, Uwe Paul; Srinivasan, Ramya; Narisetty, Haritez; Malik, Shobhit; Madhavan, Sriram
2017-04-01
In nano-meter scale Integrated Circuits, via fails due to random defects is a well-known yield detractor, and via redundancy insertion is a common method to help enhance semiconductors yield. For the case of Self Aligned Double Patterning (SADP), which might require unidirectional design layers as in the case of some advanced technology nodes, the conventional methods of inserting redundant vias don't work any longer. This is because adding redundant vias conventionally requires adding metal shapes in the non-preferred direction, which will violate the SADP design constraints in that case. Therefore, such metal layers fabricated using unidirectional SADP require an alternative method for providing the needed redundancy. This paper proposes a post-layout Design for Manufacturability (DFM) redundancy insertion method tailored for the design requirements introduced by unidirectional metal layers. The proposed method adds redundant wires in the preferred direction - after searching for nearby vacant routing tracks - in order to provide redundant paths for electrical signals. This method opportunistically adds robustness against failures due to silicon defects without impacting area or incurring new design rule violations. Implementation details of this redundancy insertion method will be explained in this paper. One known challenge with similar DFM layout fixing methods is the possible introduction of undesired electrical impact, causing other unintentional failures in design functionality. In this paper, a study is presented to quantify the electrical impacts of such redundancy insertion scheme and to examine if that electrical impact can be tolerated. The paper will show results to evaluate DFM insertion rates and corresponding electrical impact for a given design utilization and maximum inserted wire length. Parasitic extraction and static timing analysis results will be presented. A typical digital design implemented using GLOBALFOUNDRIES 7nm technology is used for demonstration. The provided results can help evaluate such extensive DFM insertion method from an electrical standpoint. Furthermore, the results could provide guidance on how to implement the proposed method of adding electrical redundancy such that intolerable electrical impacts could be avoided.
Insertion device and method for accurate and repeatable target insertion
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gubeli, III, Joseph F.; Shinn, Michelle D.; Bevins, Michael E.
The present invention discloses a device and a method for inserting and positioning a target within a free electron laser, particle accelerator, or other such device that generates or utilizes a beam of energy or particles. The system includes a three-point registration mechanism that insures angular and translational accuracy and repeatability of positioning upon multiple insertions within the same structure.
Thermostability analysis of line-tension-associated nucleation at a gas-liquid interface.
Singha, Sanat Kumar; Das, Prasanta Kumar; Maiti, Biswajit
2017-01-01
The influence of line tension on the thermostability of a droplet nucleated from an oversaturated vapor at the interface of the vapor and another immiscible liquid is investigated. Along with the condition of mechanical equilibrium, the notion of extremization of the reversible work of formation is considered to obtain the critical parameters related to heterogeneous nucleation. From the energetic formulation, the critical reversible work of formation is found to be greater than that of homogeneous nucleation for high value of the positive line tension. On the other hand, for high value of the negative line tension, the critical reversible work of formation becomes negative. Therefore, these thermodynamic instabilities under certain substrate wettability situations necessitate a free-energetics-based stability of the nucleated droplet, because the system energy is not minimized under these conditions. This thermostability is analogous to the transition-based stability proposed by Widom [B. Widom, J. Phys. Chem. 99, 2803 (1995)]10.1021/j100009a041 in the case of partial wetting phenomena along with the positive line tension. The thermostability analysis limits the domain of the solution space of the present critical-value problem as the thermodynamic transformation in connection with homogeneous and workless nucleation is considered. Within the stability range of the geometry-based wetting parameters, three limiting modes of nucleation, i.e., total-dewetting-related homogeneous nucleation, and total-wetting-associated and total-submergence-associated workless nucleation scenarios, are identified. Either of the two related limiting wetting scenarios of workless nucleation, namely, total wetting and total submergence, is found to be favorable depending on the geometry-based wetting conditions. The line-tension-associated nucleation on a liquid surface can be differentiated from that on a rigid substrate, as in the former, the stability based on mechanical equilibrium and a typical case of workless nucleation with complete submergence are observed.
A novel perfusion-based method for cochlear implant electrode insertion.
Kale, Sushrut; Cervantes, Vanessa M; Wu, Mailing R; Pisano, Dominic V; Sheth, Nakul; Olson, Elizabeth S
2014-08-01
A cochlear implant (CI) restores partial hearing to profoundly deaf individuals. CI electrodes are inserted manually in the cochlea and surgeons rely on tactile feedback from the implant to determine when to stop the insertion. This manual insertion method results in a large degree of variability in surgical outcomes and intra-cochlear trauma. Additionally, implants often span only the basal turn. In the present study we report on the development of a new method to assist CI electrode insertion. The design objectives are (1) an automated and standardized insertion technique across patients with (2) more apical insertion than is possible by the contemporary methods, while (3) minimizing insertion trauma. The method relies on a viscous fluid flow through the cochlea to carry the electrode array with it. A small cochleostomy (∼100-150 um in diameter) is made in scala vestibuli (SV) and the round window (RW) membrane is opened. A flow of diluted Sodium Hyaluronate (also known as Hyaluronic Acid, (HA)) is set up from the RW to the SV opening using a perfusion pump that sets up a unidirectional flow. Once the flow is established an implant is dropped into the ongoing flow. Here we present a proof-of-concept study where we used this technique to insert silicone implants all the way to the cochlear apex in rats and gerbils. In light-microscopic histology, the implantation occurred without cochlear trauma. To further assess the ototoxicity of the HA perfusion, we measured compound action potential (CAP) thresholds following the perfusion of HA, and found that the CAP thresholds were substantially elevated. Thus, at this point the method is promising, and requires further development to become clinically viable. Copyright © 2014 Elsevier B.V. All rights reserved.
Method of joining a vane cavity insert to a nozzle segment of a gas turbine
Burdgick, Steven Sebastian
2002-01-01
An insert containing apertures for impingement cooling a nozzle vane of a nozzle segment in a gas turbine is inserted into one end of the vane. The leading end of the insert is positioned slightly past a rib adjacent the opposite end of the vane through which the insert is inserted. The end of the insert is formed or swaged into conformance with the inner margin of the rib. The insert is then brazed or welded to the rib.
Redundant via insertion in self-aligned double patterning
NASA Astrophysics Data System (ADS)
Song, Youngsoo; Jung, Jinwook; Shin, Youngsoo
2017-03-01
Redundant via (RV) insertion is employed to enhance via manufacturability, and has been extensively studied. Self-aligned double patterning (SADP) process, brings a new challenge to RV insertion since newly created cut for each RV insertion has to be taken care of. Specifically, when a cut for RV, which we simply call RV-cut, is formed, cut conflict may occur with nearby line-end cuts, which results in a decrease in RV candidates. We introduce cut merging to reduce the number of cut conflicts; merged cuts are processed with stitch using litho-etch-litho-etch (LELE) multi-patterning method. In this paper, we propose a new RV insertion method with cut merging in SADP for the first time. In our experiments, a simple RV insertion yields 55.3% vias to receives RVs; our proposed method that considers cut merging increases that number to 69.6% on average of test circuits.
Statistical Mechanics: A Concise Introduction for Chemists (by Benjamin Widom)
NASA Astrophysics Data System (ADS)
Kovac, Jeffrey
2002-11-01
This book should be in the hands of everyone who teaches undergraduate physical chemistry to provide a model for what can be taught in that course beyond the material contained in the standard textbooks. Graduate students and faculty who need to learn statistical mechanics can hardly find a better introduction. Even those who regularly teach a graduate course in this area will get some new ideas and inspiration from one of the leading practitioners of the field. For completeness, I must add that the book has one weakness. Although there are excellent in-chapter exercises with solutions, there are no end-of-chapter problems. Since there are many sources of good problems, this is a minor flaw in an otherwise wonderful book.
Automatic insertion of simulated microcalcification clusters in a software breast phantom
NASA Astrophysics Data System (ADS)
Shankla, Varsha; Pokrajac, David D.; Weinstein, Susan P.; DeLeo, Michael; Tuite, Catherine; Roth, Robyn; Conant, Emily F.; Maidment, Andrew D.; Bakic, Predrag R.
2014-03-01
An automated method has been developed to insert realistic clusters of simulated microcalcifications (MCs) into computer models of breast anatomy. This algorithm has been developed as part of a virtual clinical trial (VCT) software pipeline, which includes the simulation of breast anatomy, mechanical compression, image acquisition, image processing, display and interpretation. An automated insertion method has value in VCTs involving large numbers of images. The insertion method was designed to support various insertion placement strategies, governed by probability distribution functions (pdf). The pdf can be predicated on histological or biological models of tumor growth, or estimated from the locations of actual calcification clusters. To validate the automated insertion method, a 2-AFC observer study was designed to compare two placement strategies, undirected and directed. The undirected strategy could place a MC cluster anywhere within the phantom volume. The directed strategy placed MC clusters within fibroglandular tissue on the assumption that calcifications originate from epithelial breast tissue. Three radiologists were asked to select between two simulated phantom images, one from each placement strategy. Furthermore, questions were posed to probe the rationale behind the observer's selection. The radiologists found the resulting cluster placement to be realistic in 92% of cases, validating the automated insertion method. There was a significant preference for the cluster to be positioned on a background of adipose or mixed adipose/fibroglandular tissues. Based upon these results, this automated lesion placement method will be included in our VCT simulation pipeline.
Critical behavior of quasi-two-dimensional semiconducting ferromagnet Cr 2 Ge 2 Te 6
Liu, Yu; Petrovic, C.
2017-08-03
Some critical properties of the single-crystalline semiconducting ferromagnet Cr 2 Ge 2 Te 6 were investigated by bulk dc magnetization around the paramagnetic to ferromagnetic phase transition. Critical exponents β = 0.200 ± 0.003 with a critical temperature T c = 62.65 ± 0.07 K and γ = 1.28 ± 0.03 with T c = 62.75 ± 0.06 K are obtained by the Kouvel-Fisher method whereas δ = 7.96 ± 0.01 is obtained by a critical isotherm analysis at T c = 62.7 K. These critical exponents obey the Widom scaling relation δ = 1 + γ / β ,more » indicating self-consistency of the obtained values. Furthermore, with these critical exponents the isotherm M ( H ) curves below and above the critical temperatures collapse into two independent universal branches, obeying the single scaling equation m = f ± ( h ) , where m and h are renormalized magnetization and field, respectively. The determined exponents match well with those calculated from the results of the renormalization group approach for a two-dimensional Ising system coupled with a long-range interaction between spins decaying as J ( r ) ≈ r - ( d + σ ) with σ = 1.52 .« less
Spectral gene set enrichment (SGSE).
Frost, H Robert; Li, Zhigang; Moore, Jason H
2015-03-03
Gene set testing is typically performed in a supervised context to quantify the association between groups of genes and a clinical phenotype. In many cases, however, a gene set-based interpretation of genomic data is desired in the absence of a phenotype variable. Although methods exist for unsupervised gene set testing, they predominantly compute enrichment relative to clusters of the genomic variables with performance strongly dependent on the clustering algorithm and number of clusters. We propose a novel method, spectral gene set enrichment (SGSE), for unsupervised competitive testing of the association between gene sets and empirical data sources. SGSE first computes the statistical association between gene sets and principal components (PCs) using our principal component gene set enrichment (PCGSE) method. The overall statistical association between each gene set and the spectral structure of the data is then computed by combining the PC-level p-values using the weighted Z-method with weights set to the PC variance scaled by Tracy-Widom test p-values. Using simulated data, we show that the SGSE algorithm can accurately recover spectral features from noisy data. To illustrate the utility of our method on real data, we demonstrate the superior performance of the SGSE method relative to standard cluster-based techniques for testing the association between MSigDB gene sets and the variance structure of microarray gene expression data. Unsupervised gene set testing can provide important information about the biological signal held in high-dimensional genomic data sets. Because it uses the association between gene sets and samples PCs to generate a measure of unsupervised enrichment, the SGSE method is independent of cluster or network creation algorithms and, most importantly, is able to utilize the statistical significance of PC eigenvalues to ignore elements of the data most likely to represent noise.
Bhattarai, Sushila; Alany, Raid G; Bunt, Craig R; Abdelkader, Hamdy; Rathbone, Michael J
2015-01-01
This manuscript reports (for the first time) on antibiotic-free polymeric inserts for the prevention and/or treatment of bovine mastitis. Polyethylene oxide (PEO)-based inserts were prepared using different concentrations of various hydrophilic polymers and water-soluble and water-insoluble drug-release-modifying excipients. A simple and scalable melt-extrusion method was employed to prepare the inserts. The prepared inserts were characterised for their dimension, rheological and mechanical properties. The in vitro release of a model bacteriostatic drug (salicylic acid) from the prepared inserts was studied to demonstrate the effectiveness and reproducibility of the melt-extrusion manufacturing method. Further, the in vitro stability of the inserts was evaluated using gel permeation chromatography (GPC) to monitor any change in molecular weight under real-time and accelerated storage conditions. The investigated inserts were stable at accelerated storage conditions over a period of 6 months. PEO inserts have the potential to serve a dual purpose, act as a physical barrier against pathogens invading the teat canal of cows and possibly control the release of a drug.
A proposed model membrane and test method for microneedle insertion studies.
Larrañeta, Eneko; Moore, Jessica; Vicente-Pérez, Eva M; González-Vázquez, Patricia; Lutton, Rebecca; Woolfson, A David; Donnelly, Ryan F
2014-09-10
A commercial polymeric film (Parafilm M(®), a blend of a hydrocarbon wax and a polyolefin) was evaluated as a model membrane for microneedle (MN) insertion studies. Polymeric MN arrays were inserted into Parafilm M(®) (PF) and also into excised neonatal porcine skin. Parafilm M(®) was folded before the insertions to closely approximate thickness of the excised skin. Insertion depths were evaluated using optical coherence tomography (OCT) using either a force applied by a Texture Analyser or by a group of human volunteers. The obtained insertion depths were, in general, slightly lower, especially for higher forces, for PF than for skin. However, this difference was not a large, being less than the 10% of the needle length. Therefore, all these data indicate that this model membrane could be a good alternative to biological tissue for MN insertion studies. As an alternative method to OCT, light microscopy was used to evaluate the insertion depths of MN in the model membrane. This provided a rapid, simple method to compare different MN formulations. The use of Parafilm M(®), in conjunction with a standardised force/time profile applied by a Texture Analyser, could provide the basis for a rapid MN quality control test suitable for in-process use. It could also be used as a comparative test of insertion efficiency between candidate MN formulations. Copyright © 2014 The Authors. Published by Elsevier B.V. All rights reserved.
Rossa, Carlos; Sloboda, Ron; Usmani, Nawaid; Tavakoli, Mahdi
2016-07-01
This paper proposes a method to predict the deflection of a flexible needle inserted into soft tissue based on the observation of deflection at a single point along the needle shaft. We model the needle-tissue as a discretized structure composed of several virtual, weightless, rigid links connected by virtual helical springs whose stiffness coefficient is found using a pattern search algorithm that only requires the force applied at the needle tip during insertion and the needle deflection measured at an arbitrary insertion depth. Needle tip deflections can then be predicted for different insertion depths. Verification of the proposed method in synthetic and biological tissue shows a deflection estimation error of [Formula: see text]2 mm for images acquired at 35 % or more of the maximum insertion depth, and decreases to 1 mm for images acquired closer to the final insertion depth. We also demonstrate the utility of the model for prostate brachytherapy, where in vivo needle deflection measurements obtained during early stages of insertion are used to predict the needle deflection further along the insertion process. The method can predict needle deflection based on the observation of deflection at a single point. The ultrasound probe can be maintained at the same position during insertion of the needle, which avoids complications of tissue deformation caused by the motion of the ultrasound probe.
Kuvaki, B; Küçükgüçlü, S; Iyilikçi, L; Tuncali, B E; Cinar, O
2008-10-01
We investigated whether insertion of the disposable Soft Seal laryngeal mask airway (SSLM) was successful without intra-oral digital manipulation. One hundred patients undergoing anaesthesia using the SSLM were randomly assigned into two groups. Insertion was performed by either a direct or a rotational technique, both without intra-oral digital manipulation. The primary outcome measure was successful insertion at first attempt. Other outcomes included insertion time, fibreoptic assessment of the airway view and airway morbidity. The first attempt success rate was higher (98%) with the direct technique than with the rotational technique (75%; p = 0.002) but insertion time was faster with the latter method (mean [range] 15 [8-50] s) than with the direct method (20 [8-56] s; p = 0.035). Fibreoptic assessment and airway morbidity were similar in both groups. We conclude that the SSLM can be successfully inserted without intra-oral digital manipulation.
Martin, Charles E; Fontaine, Lucien; Gardner, William H
2014-01-21
An electrochemical cell includes components that are welded from an external source after the components are assembled in a cell canister. The cell canister houses electrode tabs and a core insert. An end cap insert is disposed opposite the core insert. An external weld source, such as a laser beam, is applied to the end cap insert, such that the end cap insert, the electrode tabs, and the core insert are electrically coupled by a weld which extends from the end cap insert to the core insert.
Validation of a Projection-domain Insertion of Liver Lesions into CT Images
Chen, Baiyu; Ma, Chi; Leng, Shuai; Fidler, Jeff L.; Sheedy, Shannon P.; McCollough, Cynthia H.; Fletcher, Joel G.; Yu, Lifeng
2016-01-01
Rationale and Objectives The aim of this study was to validate a projection-domain lesion-insertion method with observer studies. Materials and Methods A total of 51 proven liver lesions were segmented from computed tomography images, forward projected, and inserted into patient projection data. The images containing inserted and real lesions were then reconstructed and examined in consensus by two radiologists. First, 102 lesions (51 original, 51 inserted) were viewed in a randomized, blinded fashion and scored from 1 (absolutely inserted) to 10 (absolutely real). Statistical tests were performed to compare the scores for inserted and real lesions. Subsequently, a two-alternative-forced-choice test was conducted, with lesions viewed in pairs (real vs. inserted) in a blinded fashion. The radiologists selected the inserted lesion and provided a confidence level of 1 (no confidence) to 5 (completely certain). The number of lesion pairs that were incorrectly classified was calculated. Results The scores for inserted and proven lesions had the same median (8) and similar interquartile ranges (inserted, 5.5–8; real, 6.5–8). The means scores were not significantly different between real and inserted lesions (P value = 0.17). The receiver operating characteristic curve was nearly diagonal, with an area under the curve of 0.58 ± 0.06. For the two-alternative-forced-choice study, the inserted lesions were incorrectly identified in 49% (25 out of 51) of pairs; radiologists were incorrect in 38% (3 out of 8) of pairs even when they felt very confident in identifying the inserted lesion (confidence level ≥4). Conclusions Radiologists could not distinguish between inserted and real lesions, thereby validating the lesion-insertion technique, which may be useful for conducting virtual clinical trials to optimize image quality and radiation dose. PMID:27432267
Insertion of lithium into electrochromic devices after completion
Berland, Brian Spencer; Lanning, Bruce Roy; Frey, Jonathan Mack; Barrett, Kathryn Suzanne; DuPont, Paul Damon; Schaller, Ronald William
2015-12-22
The present disclosure describes methods of inserting lithium into an electrochromic device after completion. In the disclosed methods, an ideal amount of lithium can be added post-fabrication to maximize or tailor the free lithium ion density of a layer or the coloration range of a device. Embodiments are directed towards a method to insert lithium into the main device layers of an electrochromic device as a post-processing step after the device has been manufactured. In an embodiment, the methods described are designed to maximize the coloration range while compensating for blind charge loss.
Kizaki, Seiichiro; Zou, Tingting; Li, Yue; Han, Yong-Woon; Suzuki, Yuki; Harada, Yoshie; Sugiyama, Hiroshi
2016-11-07
Tet (ten-eleven translocation) family proteins oxidize 5-methylcytosine (mC) to 5-hydroxymethylcytosine (hmC), 5-formylcytosine (fC), and 5-carboxycytosine (caC), and are suggested to be involved in the active DNA demethylation pathway. In this study, we reconstituted positioned mononucleosomes using CpG-methylated 382 bp DNA containing the Widom 601 sequence and recombinant histone octamer, and subjected the nucleosome to treatment with Tet1 protein. The sites of oxidized methylcytosine were identified by bisulfite sequencing. We found that, for the oxidation reaction, Tet1 protein prefers mCs located in the linker region of the nucleosome compared with those located in the core region. © 2016 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
Verification of Triple Modular Redundancy (TMR) Insertion for Reliable and Trusted Systems
NASA Technical Reports Server (NTRS)
Berg, Melanie; LaBel, Kenneth A.
2016-01-01
We propose a method for TMR insertion verification that satisfies the process for reliable and trusted systems. If a system is expected to be protected using TMR, improper insertion can jeopardize the reliability and security of the system. Due to the complexity of the verification process, there are currently no available techniques that can provide complete and reliable confirmation of TMR insertion. This manuscript addresses the challenge of confirming that TMR has been inserted without corruption of functionality and with correct application of the expected TMR topology. The proposed verification method combines the usage of existing formal analysis tools with a novel search-detect-and-verify tool. Field programmable gate array (FPGA),Triple Modular Redundancy (TMR),Verification, Trust, Reliability,
Hiraki, Takao; Kamegawa, Tetsushi; Matsuno, Takayuki; Sakurai, Jun; Kirita, Yasuzo; Matsuura, Ryutaro; Yamaguchi, Takuya; Sasaki, Takanori; Mitsuhashi, Toshiharu; Komaki, Toshiyuki; Masaoka, Yoshihisa; Matsui, Yusuke; Fujiwara, Hiroyasu; Iguchi, Toshihiro; Gobara, Hideo; Kanazawa, Susumu
2017-11-01
Purpose To evaluate the accuracy of the remote-controlled robotic computed tomography (CT)-guided needle insertion in phantom and animal experiments. Materials and Methods In a phantom experiment, 18 robotic and manual insertions each were performed with 19-gauge needles by using CT fluoroscopic guidance for the evaluation of the equivalence of accuracy of insertion between the two groups with a 1.0-mm margin. Needle insertion time, CT fluoroscopy time, and radiation exposure were compared by using the Student t test. The animal experiments were approved by the institutional animal care and use committee. In the animal experiment, five robotic insertions each were attempted toward targets in the liver, kidneys, lungs, and hip muscle of three swine by using 19-gauge or 17-gauge needles and by using conventional CT guidance. The feasibility, safety, and accuracy of robotic insertion were evaluated. Results The mean accuracies of robotic and manual insertion in phantoms were 1.6 and 1.4 mm, respectively. The 95% confidence interval of the mean difference was -0.3 to 0.6 mm. There were no significant differences in needle insertion time, CT fluoroscopy time, or radiation exposure to the phantom between the two methods. Effective dose to the physician during robotic insertion was always 0 μSv, while that during manual insertion was 5.7 μSv on average (P < .001). Robotic insertion was feasible in the animals, with an overall mean accuracy of 3.2 mm and three minor procedure-related complications. Conclusion Robotic insertion exhibited equivalent accuracy as manual insertion in phantoms, without radiation exposure to the physician. It was also found to be accurate in an in vivo procedure in animals. © RSNA, 2017 Online supplemental material is available for this article.
Method for improving the durability of ion insertion materials
Lee, Se-Hee; Tracy, C. Edwin; Cheong, Hyeonsik M.
2002-01-01
The invention provides a method of protecting an ion insertion material from the degradative effects of a liquid or gel-type electrolyte material by disposing a protective, solid ion conducting, electrically insulating, layer between the ion insertion layer and the liquid or gel-type electrolyte material. The invention further provides liquid or gel-type electrochemical cells having improved durability having a pair of electrodes, a pair of ion insertion layers sandwiched between the pair of electrodes, a pair of solid ion conducting layers sandwiched between the ion insertion layers, and a liquid or gel-type electrolyte material disposed between the solid ion conducting layers, where the solid ion conducting layer minimizes or prevents degradation of the faces of the ion insertion materials facing the liquid or gel-type electrolyte material. Electrochemical cells of this invention having increased durability include secondary lithium batteries and electrochromic devices.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hunt, J.G.; Jenkins, R.G.; White, A.M.
1963-03-01
A number of ceramics, metallic compounds, and ceramic-metal composites were successfully hot pressed into the shape of die inserts. Steels were extruded through several of these for the purpose of evaluating the materials or to study methods of supporting the die inserts. Refractory metal inserts were also used in similar tests. Hot pressed inserts consisting of 80 vo1% Al/sub 2/O/ sub 3/--10 vol% W and 80 vol% ThO/sub 2/--10 vol% W cracked but did not erode. Sintered molybdenum inserts flowed excessively, whereas sintered tungsten inserts flowed to a lesser degree. A hard die casing with a slight shrink fit appearsmore » to be the most satisfactory method of support. (auth)« less
Insertion of coherence requests for debugging a multiprocessor
Blumrich, Matthias A.; Salapura, Valentina
2010-02-23
A method and system are disclosed to insert coherence events in a multiprocessor computer system, and to present those coherence events to the processors of the multiprocessor computer system for analysis and debugging purposes. The coherence events are inserted in the computer system by adding one or more special insert registers. By writing into the insert registers, coherence events are inserted in the multiprocessor system as if they were generated by the normal coherence protocol. Once these coherence events are processed, the processing of coherence events can continue in the normal operation mode.
Metrology to quantify wear and creep of polyethylene tibial knee inserts.
Muratoglu, Orhun K; Perinchief, Rebecca S; Bragdon, Charles R; O'Connor, Daniel O; Konrad, Reto; Harris, William H
2003-05-01
Assessment of damage on articular surfaces of ultrahigh molecular weight polyethylene tibial knee inserts primarily has been limited to qualitative methods, such as visual observation and classification of features such as pitting, delamination, and subsurface cracking. Semiquantitative methods also have been proposed to determine the linear penetration and volume of the scar that forms on articular surfaces of tibial knee inserts. The current authors report a new metrologic method that uses a coordinate measuring machine to quantify the dimensions of this scar. The articular surface of the insert is digitized with the coordinate measuring machine before and after regular intervals of testing on a knee simulator. The volume and linear penetration of the scar are calculated by mathematically taking the difference between the digitized surface maps of the worn and unworn articular surfaces. Three conventional polyethylene tibial knee inserts of a posterior cruciate-sparing design were subjected to five million cycles of normal gait on a displacement-driven knee wear simulator in bovine serum. A metrologic method was used to calculate creep and wear contributions to the scar formation on each tibial plateau. Weight loss of the inserts was determined gravimetrically with the appropriate correction for fluid absorption. The total average wear volume was 43 +/- 9 and 41 +/- 4 mm3 measured by the metrologic and gravimetric methods, respectively. The wear rate averaged 8.3 +/- 0.9 and 8.5 +/- 1.6 mm3 per million cycles measured by the metrologic and gravimetric methods, respectively. These comparisons reflected strong agreement between the metrologic and gravimetric methods.
Tavakolian, Samira; Doulabi, Mahbobeh Ahmadi; Baghban, Alireza Akbarzade; Mortazavi, Alireza; Ghorbani, Maryam
2015-01-01
Introduction: Copper IUD is a long term and reversible contraception which equals tubal ligation in terms of sterilization. One of the barriers to using this contraception method is the fear and the pain associated with its insertion. Eutectic mixture of local anesthetics (EMLA) 5% is a local anesthetic that contains 25 mg lidocaine and 25 mg of prilocaine per gram. Application of topical analgesic cream to the cervix for laser surgery, hysteroscopy and hysterosalpingography is known Aims: this study aimed to determine the effect of EMLA on IUD insertion pain. Methods: This triple blind clinical trial was conducted on 92 women in a clinic in Hamedan in 2012. After applying the cream on the cervix, pain in three steps, after using Tenaculum, after inserting hystrometr and after inserting IUD and removing IUD insertion tube were assessed with visual analog scale and were compared in EMLA group and placebo group Statistical analysis used to determine and compare the pain of independent t tests, Mann-Whitney U test and repeated measures analysis of variance and chi-square tests to determine the homogeneity of variables and Fisher’s exact test was used Results: Insertion hystrometr was determined as the most painful IUD insertion. The mean pain at step 2 (inserting hystrometr) was (3/11±2/53) in EMLA group, (5/23±2/31) in placebo group. EMLA cream significantly reduced the pain after using tenaculum (P<0/001), pain inserting Hystrometr (P< 0/001) and pain at IUD insertion and removing insertion tube (P< 0/001) Conclusions: Topical Application of EMLA 5% cream as a topical anesthetic on the cervix before insertion IUD reduced the pain during this procedure. PMID:25946948
Insertable fluid flow passage bridgepiece and method
Jones, Daniel O.
2000-01-01
A fluid flow passage bridgepiece for insertion into an open-face fluid flow channel of a fluid flow plate is provided. The bridgepiece provides a sealed passage from a columnar fluid flow manifold to the flow channel, thereby preventing undesirable leakage into and out of the columnar fluid flow manifold. When deployed in the various fluid flow plates that are used in a Proton Exchange Membrane (PEM) fuel cell, bridgepieces of this invention prevent mixing of reactant gases, leakage of coolant or humidification water, and occlusion of the fluid flow channel by gasket material. The invention also provides a fluid flow plate assembly including an insertable bridgepiece, a fluid flow plate adapted for use with an insertable bridgepiece, and a method of manufacturing a fluid flow plate with an insertable fluid flow passage bridgepiece.
Finke, John M; Cheung, Margaret S; Onuchic, José N
2004-09-01
Modeling the structure of natively disordered peptides has proved difficult due to the lack of structural information on these peptides. In this work, we use a novel application of the host-guest method, combining folding theory with experiments, to model the structure of natively disordered polyglutamine peptides. Initially, a minimalist molecular model (C(alpha)C(beta)) of CI2 is developed with a structurally based potential and captures many of the folding properties of CI2 determined from experiments. Next, polyglutamine "guest" inserts of increasing length are introduced into the CI2 "host" model and the polyglutamine is modeled to match the resultant change in CI2 thermodynamic stability between simulations and experiments. The polyglutamine model that best mimics the experimental changes in CI2 thermodynamic stability has 1), a beta-strand dihedral preference and 2), an attractive energy between polyglutamine atoms 0.75-times the attractive energy between the CI2 host Go-contacts. When free-energy differences in the CI2 host-guest system are correctly modeled at varying lengths of polyglutamine guest inserts, the kinetic folding rates and structural perturbation of these CI2 insert mutants are also correctly captured in simulations without any additional parameter adjustment. In agreement with experiments, the residues showing structural perturbation are located in the immediate vicinity of the loop insert. The simulated polyglutamine loop insert predominantly adopts extended random coil conformations, a structural model consistent with low resolution experimental methods. The agreement between simulation and experimental CI2 folding rates, CI2 structural perturbation, and polyglutamine insert structure show that this host-guest method can select a physically realistic model for inserted polyglutamine. If other amyloid peptides can be inserted into stable protein hosts and the stabilities of these host-guest mutants determined, this novel host-guest method may prove useful to determine structural preferences of these intractable but biologically relevant protein fragments.
Method for introducing unidirectional nested deletions
Dunn, John J.; Quesada, Mark A.; Randesi, Matthew
2001-01-01
Disclosed is a method for the introduction of unidirectional deletions in a cloned DNA segment in the context of a cloning vector which contains an f1 endonuclease recognition sequence adjacent to the insertion site of the DNA segment. Also disclosed is a method for producing single-stranded DNA probes utilizing the same cloning vector. An optimal vector, PZIP is described. Methods for introducing unidirectional deletions into a terminal location of a cloned DNA sequence which is inserted into the vector of the present invention are also disclosed. These methods are useful for introducing deletions into either or both ends of a cloned DNA insert, for high throughput sequencing of any DNA of interest.
NASA Astrophysics Data System (ADS)
Korotkov, E. V.; Korotkova, M. A.
2017-01-01
The purpose of this study was to detect latent periodicity in the presence of deletions or insertions in the analyzed data, when the points of deletions or insertions are unknown. A mathematical method was developed to search for periodicity in the numerical series, using dynamic programming and random matrices. The developed method was applied to search for periodicity in the Euro/Dollar (Eu/) exchange rate, since 2001. The presence of periodicity within the period length equal to 24 h in the analyzed financial series was shown. Periodicity can be detected only with insertions and deletions. The results of this study show that periodicity phase shifts, depend on the observation time. The reasons for the existence of the periodicity in the financial ranks are discussed.
Mass-flow-rate-controlled fluid flow in nanochannels by particle insertion and deletion.
Barclay, Paul L; Lukes, Jennifer R
2016-12-01
A nonequilibrium molecular dynamics method to induce fluid flow in nanochannels, the insertion-deletion method (IDM), is introduced. IDM inserts and deletes particles within distinct regions in the domain, creating locally high and low pressures. The benefits of IDM are that it directly controls a physically meaningful quantity, the mass flow rate, allows for pressure and density gradients to develop in the direction of flow, and permits treatment of complex aperiodic geometries. Validation of IDM is performed, yielding good agreement with the analytical solution of Poiseuille flow in a planar channel. Comparison of IDM to existing methods indicates that it is best suited for gases, both because it intrinsically accounts for compressibility effects on the flow and because the computational cost of particle insertion is lowest for low-density fluids.
Descemet's Stripping Automated Endothelial Keratoplasty Tissue Insertion Devices
Khan, Salman Nasir; Shiakolas, Panos S.; Mootha, Venkateswara Vinod
2015-01-01
This review study provides information regarding the construction, design, and use of six commercially available endothelial allograft insertion devices applied for Descemet's stripping automated endothelial keratoplasty (DSAEK). We also highlight issues being faced in DSAEK and discuss the methods through which medical devices such as corneal inserters may alleviate these issues. Inserter selection is of high importance in the DSAEK procedure since overcoming the learning curve associated with the use of an insertion device is a time and energy consuming process. In the present review, allograft insertion devices were compared in terms of design, construction material, insertion technique, dimensions, incision requirements and endothelial cell loss to show their relative merits and capabilities based on available data in the literature. Moreover, the advantages/disadvantages of various insertion devices used for allograft insertion in DSAEK are reviewed and compared. The information presented in this review can be utilized for better selection of an insertion device for DSAEK. PMID:27051492
Jung, Kihwan; Kim, Hojong
2015-01-01
Background and Objectives To evaluate the relationship between age and anesthesia method used for tympanostomy tube insertion (TTI) and to provide evidence to guide the selection of an appropriate anesthesia method in children. Subjects and Methods We performed a retrospective review of children under 15 years of age who underwent tympanostomy tube insertion (n=159) or myringotomy alone (n=175) under local or general anesthesia by a single surgeon at a university-based, secondary care referral hospital. Epidermiologic data between local and general anesthesia groups as well as between TTI and myringotomy were analyzed. Medical costs were compared between local and general anesthesia groups. Results Children who received local anesthesia were significantly older than those who received general anesthesia. Unilateral tympanostomy tube insertion was performed more frequently under local anesthesia than bilateral. Logistic regression modeling showed that local anesthesia was more frequently applied in older children (odds ratio=1.041) and for unilateral tympanostomy tube insertion (odds ratio=8.990). The cut-off value of age for local anesthesia was roughly 5 years. Conclusions In a pediatric population at a single medical center, age and whether unilateral or bilateral procedures were required were important factors in selecting an anesthesia method for tympanostomy tube insertion. Our findings suggest that local anesthesia can be preferentially considered for children 5 years of age or older, especially in those with unilateral otitis media with effusion. PMID:26185791
Konstantinou, Evangelos A; Stafylarakis, Emmanuil; Kapritsou, Maria; Mitsos, Aristotelis P; Fotis, Theofanis G; Kiekkas, Panagiotis; Mariolis-Sapsakos, Theodoros; Argyras, Eriphyli; Nomikou, Irini Th; Dimitrakopoulos, Antonios
2012-09-01
Placement of peripherally inserted central catheters (PICCs), definitely offers a clear advantage over any other method regarding central venous catheterization. Its ultrasonographic orientation enhances significantly its accuracy, safety and efficacy, making this method extremely comfortable for the patient who can continue his or her therapy even in an outpatient basis. We present the first reported case of a PICCS insertion in Greece, which has been performed by a university-degree nurse. The aim of this review of literature was to present the evolution in nursing practice in Greece. A PICC was inserted in a 77-year-old male patient suffering from a recent chemical pneumonia with a history of Alzheimer's disease. A description of all the technical details of this insertion is reported, focusing on the pros and cons of the method and a thorough review of the history and advances in central venous catheterization throughout the years is also presented. PICCs provide long-term intravenous access and facilitate the delivery of extended antibiotic therapy, chemotherapy and total parenteral nutrition. We strongly believe that PICCs are the safest and most effective method of peripherally inserted central venous catheterization. Larger series are necessary to prove the above hypothesis, and they are under construction by our team. Copyright © 2012 Society for Vascular Nursing, Inc. Published by Mosby, Inc. All rights reserved.
Effect of shoe inserts on kinematics, center of pressure, and leg joint moments during running.
Nigg, Benno M; Stergiou, Pro; Cole, Gerald; Stefanyshyn, Darren; Mündermann, Anne; Humble, Neil
2003-02-01
The purposes of this project were to assess the effect of four different shoe inserts on the path of the center of pressure (COP), to quantify the effect of these inserts on selected knee joint moments during running, and to assess the potential of COP data to predict the effects of inserts/orthotics on knee joint moments. Kinematics for the lower extremities, resultant ankle and knee joint moments, and the path of the COP were collected from the right foot of 15 male subjects while running heel-toe with five different shoe inserts (full or half with 4.5-mm postings). Individual movement changes with respect to the neutral insert condition were typically small and not systematic. Significant changes for the path of the COP were registered only for the full lateral insert condition with an average shift toward the lateral side. The mediolateral shift of the COP was not consistent for the full medial and the two half-shoe inserts. The subject-specific reactions to the inserts' intervention in the corresponding knee joint moments were typically not consistent. Compared with the neutral insert condition, subjects showed increases or decreases of the knee joint moments. The correlation between the individual COP shifts and the resultant knee joint moment was generally small. The results of this study showed that subject-specific reactions to the tested inserts were often not as expected. Additionally, reactions were not consistent between the subjects. This result suggests that the prescription of inserts and/or orthotics is a difficult task and that methods must be developed to test and assess these effects. Such methods, however, are not currently available.
The Boson peak in supercooled water.
Kumar, Pradeep; Wikfeldt, K Thor; Schlesinger, Daniel; Pettersson, Lars G M; Stanley, H Eugene
2013-01-01
We perform extensive molecular dynamics simulations of the TIP4P/2005 model of water to investigate the origin of the Boson peak reported in experiments on supercooled water in nanoconfined pores, and in hydration water around proteins. We find that the onset of the Boson peak in supercooled bulk water coincides with the crossover to a predominantly low-density-like liquid below the Widom line TW. The frequency and onset temperature of the Boson peak in our simulations of bulk water agree well with the results from experiments on nanoconfined water. Our results suggest that the Boson peak in water is not an exclusive effect of confinement. We further find that, similar to other glass-forming liquids, the vibrational modes corresponding to the Boson peak are spatially extended and are related to transverse phonons found in the parent crystal, here ice Ih.
Critical behavior of the van der Waals bonded ferromagnet Fe3 -xGeTe2
NASA Astrophysics Data System (ADS)
Liu, Yu; Ivanovski, V. N.; Petrovic, C.
2017-10-01
The critical properties of the single-crystalline van der Waals bonded ferromagnet Fe3 -xGeTe2 were investigated by bulk dc magnetization around the paramagnetic to ferromagnetic (FM) phase transition. The Fe3 -xGeTe2 single crystals grown by self-flux method with Fe deficiency x ≈0.36 exhibit bulk FM ordering below Tc=152 K. The Mössbauer spectroscopy was used to provide information on defects and local atomic environment in such crystals. Critical exponents β =0.372 (4 ) with a critical temperature Tc=151.25 (5 ) K and γ =1.265 (15 ) with Tc=151.17 (12 ) K are obtained by the Kouvel-Fisher method, whereas δ =4.50 (1 ) is obtained by a critical isotherm analysis at Tc=151 K. These critical exponents obey the Widom scaling relation δ =1 +γ /β , indicating self-consistency of the obtained values. With these critical exponents the isotherm M (H ) curves below and above the critical temperatures collapse into two independent universal branches, obeying the single scaling equation m =f±(h ) , where m and h are renormalized magnetization and field, respectively. The exponents determined in this study are close to those calculated from the results of the renormalization group approach for a heuristic model of three-dimensional Heisenberg (d =3 ,n =3 ) spins coupled with the attractive long-range interactions between spins that decay as J (r ) ≈r-(3 +σ ) with σ =1.89 .
Prediction of the translocon-mediated membrane insertion free energies of protein sequences.
Park, Yungki; Helms, Volkhard
2008-05-15
Helical membrane proteins (HMPs) play crucial roles in a variety of cellular processes. Unlike water-soluble proteins, HMPs need not only to fold but also get inserted into the membrane to be fully functional. This process of membrane insertion is mediated by the translocon complex. Thus, it is of great interest to develop computational methods for predicting the translocon-mediated membrane insertion free energies of protein sequences. We have developed Membrane Insertion (MINS), a novel sequence-based computational method for predicting the membrane insertion free energies of protein sequences. A benchmark test gives a correlation coefficient of 0.74 between predicted and observed free energies for 357 known cases, which corresponds to a mean unsigned error of 0.41 kcal/mol. These results are significantly better than those obtained by traditional hydropathy analysis. Moreover, the ability of MINS to reasonably predict membrane insertion free energies of protein sequences allows for effective identification of transmembrane (TM) segments. Subsequently, MINS was applied to predict the membrane insertion free energies of 316 TM segments found in known structures. An in-depth analysis of the predicted free energies reveals a number of interesting findings about the biogenesis and structural stability of HMPs. A web server for MINS is available at http://service.bioinformatik.uni-saarland.de/mins
Technical Note: Computer-Manufactured Inserts for Prosthetic Sockets
Sanders, Joan E.; McLean, Jake B.; Cagle, John C.; Gardner, David W.; Allyn, Katheryn J.
2016-01-01
The objective of this research was to use computer-aided design software and a tabletop 3-D additive manufacturing system to design and fabricate custom plastic inserts for trans-tibial prosthesis users. Shape quality of inserts was tested right after they were inserted into participant’s test sockets and again after four weeks of wear. Inserts remained properly positioned and intact throughout testing. Right after insertion the inserts caused the socket to be slightly under-sized, by a mean of 0.11 mm, approximately 55% of the thickness of a nylon sheath. After four weeks of wear the under-sizing was less, averaging 0.03 mm, approximately 15% of the thickness of a nylon sheath. Thus the inserts settled into the sockets over time. If existing prosthetic design software packages were enhanced to conduct insert design and to automatically generate fabrication files for manufacturing, then computer manufactured inserts may offer advantages over traditional methods in terms of speed of fabrication, ease of design, modification, and record keeping. PMID:27212209
Membrane Topology and Insertion of Membrane Proteins: Search for Topogenic Signals
van Geest, Marleen; Lolkema, Juke S.
2000-01-01
Integral membrane proteins are found in all cellular membranes and carry out many of the functions that are essential to life. The membrane-embedded domains of integral membrane proteins are structurally quite simple, allowing the use of various prediction methods and biochemical methods to obtain structural information about membrane proteins. A critical step in the biosynthetic pathway leading to the folded protein in the membrane is its insertion into the lipid bilayer. Understanding of the fundamentals of the insertion and folding processes will significantly improve the methods used to predict the three-dimensional membrane protein structure from the amino acid sequence. In the first part of this review, biochemical approaches to elucidate membrane protein topology are reviewed and evaluated, and in the second part, the use of similar techniques to study membrane protein insertion is discussed. The latter studies search for signals in the polypeptide chain that direct the insertion process. Knowledge of the topogenic signals in the nascent chain of a membrane protein is essential for the evaluation of membrane topology studies. PMID:10704472
NASA Astrophysics Data System (ADS)
Derevianko, Andrei; Porsev, Sergey G.
2005-03-01
We consider evaluation of matrix elements with the coupled-cluster method. Such calculations formally involve infinite number of terms and we devise a method of partial summation (dressing) of the resulting series. Our formalism is built upon an expansion of the product C†C of cluster amplitudes C into a sum of n -body insertions. We consider two types of insertions: particle (hole) line insertion and two-particle (two-hole) random-phase-approximation-like insertion. We demonstrate how to “dress” these insertions and formulate iterative equations. We illustrate the dressing equations in the case when the cluster operator is truncated at single and double excitations. Using univalent systems as an example, we upgrade coupled-cluster diagrams for matrix elements with the dressed insertions and highlight a relation to pertinent fourth-order diagrams. We illustrate our formalism with relativistic calculations of the hyperfine constant A(6s) and the 6s1/2-6p1/2 electric-dipole transition amplitude for the Cs atom. Finally, we augment the truncated coupled-cluster calculations with otherwise omitted fourth order diagrams. The resulting analysis for Cs is complete through the fourth order of many-body perturbation theory and reveals an important role of triple and disconnected quadruple excitations.
Guo, Bingfu; Guo, Yong; Hong, Huilong; Qiu, Li-Juan
2016-01-01
Molecular characterization of sequence flanking exogenous fragment insertion is essential for safety assessment and labeling of genetically modified organism (GMO). In this study, the T-DNA insertion sites and flanking sequences were identified in two newly developed transgenic glyphosate-tolerant soybeans GE-J16 and ZH10-6 based on whole genome sequencing (WGS) method. More than 22.4 Gb sequence data (∼21 × coverage) for each line was generated on Illumina HiSeq 2500 platform. The junction reads mapped to boundaries of T-DNA and flanking sequences in these two events were identified by comparing all sequencing reads with soybean reference genome and sequence of transgenic vector. The putative insertion loci and flanking sequences were further confirmed by PCR amplification, Sanger sequencing, and co-segregation analysis. All these analyses supported that exogenous T-DNA fragments were integrated in positions of Chr19: 50543767-50543792 and Chr17: 7980527-7980541 in these two transgenic lines. Identification of genomic insertion sites of G2-EPSPS and GAT transgenes will facilitate the utilization of their glyphosate-tolerant traits in soybean breeding program. These results also demonstrated that WGS was a cost-effective and rapid method for identifying sites of T-DNA insertions and flanking sequences in soybean.
Methods and compositions for controlling gene expression by RNA processing
Doudna, Jennifer A.; Qi, Lei S.; Haurwitz, Rachel E.; Arkin, Adam P.
2017-08-29
The present disclosure provides nucleic acids encoding an RNA recognition sequence positioned proximal to an insertion site for the insertion of a sequence of interest; and host cells genetically modified with the nucleic acids. The present disclosure also provides methods of modifying the activity of a target RNA, and kits and compositions for carrying out the methods.
Kim, Hyung Suk; Lee, Byung Ki; Jung, Jin-Woo; Lee, Jung Keun; Byun, Seok-Soo; Lee, Sang Eun; Jeong, Chang Wook
2014-11-01
Double-J stent insertion has been generally performed during laparoscopic upper urinary tract (UUT) surgical procedures to prevent transient urinary tract obstruction and postoperative flank pain from ureteral edema and blood clots. Several restrictive conditions that make this procedure difficult and time consuming, however, include the coiled distal ends of the flexible Double-J stent and the limited bending angle of the laparoscopic instruments. To overcome these limitations, we devised a Double-J stent insertion method using the new J-tube technique. Between July 2011 and May 2013, Double-J stents were inserted using the J-tube technique in 33 patients who underwent a laparoscopic UUT surgical procedure by a single surgeon. The mean stent placement time was 4.8±2.7 minutes, and there were no intraoperative complications. In conclusion, the J-tube technique is a safe and time-saving method for Double-J stent insertion during laparoscopic surgical procedures.
Remote vacuum or pressure sealing device and method for critical isolated systems
Brock, James David [Newport News, VA; Keith, Christopher D [Newport News, VA
2012-07-10
A remote vacuum or pressure sealing apparatus and method for making a radiation tolerant, remotely prepared seal that maintains a vacuum or pressure tight seal throughout a wide temperature range. The remote sealing apparatus includes a fixed threaded sealing surface on an isolated system, a gasket, and an insert consisting of a plug with a protruding sample holder. An insert coupling device, provided for inserting samples within the isolated system, includes a threaded fastener for cooperating with the fixed threaded sealing surface on the isolated system. The insert coupling device includes a locating pin for azimuthal orientation, coupling pins, a tooted coaxial socket wrench, and an insert coupling actuator for actuating the coupling pins. The remote aspect of the sealing apparatus maintains the isolation of the system from the user's environment, safely preserving the user and the system from detrimental effect from each respectively.
Intelligent vision guide for automatic ventilation grommet insertion into the tympanic membrane.
Gao, Wenchao; Tan, Kok Kiong; Liang, Wenyu; Gan, Chee Wee; Lim, Hsueh Yee
2016-03-01
Otitis media with effusion is a worldwide ear disease. The current treatment is to surgically insert a ventilation grommet into the tympanic membrane. A robotic device allowing automatic grommet insertion has been designed in a previous study; however, the part of the membrane where the malleus bone is attached to the inner surface is to be avoided during the insertion process. This paper proposes a synergy of optical flow technique and a gradient vector flow active contours algorithm to achieve an online tracking of the malleus under endoscopic vision, to guide the working channel to move efficiently during the surgery. The proposed method shows a more stable and accurate tracking performance than the current tracking methods in preclinical tests. With satisfactory tracking results, vision guidance of a suitable insertion spot can be provided to the device to perform the surgery in an automatic way. Copyright © 2015 John Wiley & Sons, Ltd.
3D kinematics of mobile-bearing total knee arthroplasty using X-ray fluoroscopy.
Yamazaki, Takaharu; Futai, Kazuma; Tomita, Tetsuya; Sato, Yoshinobu; Yoshikawa, Hideki; Tamura, Shinichi; Sugamoto, Kazuomi
2015-04-01
Total knee arthroplasty (TKA) 3D kinematic analysis requires 2D/3D image registration of X-ray fluoroscopic images and a computer-aided design (CAD) model of the knee implant. However, these techniques cannot provide information on the radiolucent polyethylene insert, since the insert silhouette does not appear clearly in X-ray images. Therefore, it is difficult to obtain the 3D kinematics of the polyethylene insert, particularly the mobile-bearing insert. A technique for 3D kinematic analysis of a mobile-bearing insert used in TKA was developed using X-ray fluoroscopy. The method was tested and a clinical application was evaluated. Tantalum beads and a CAD model of the mobile-bearing TKA insert are used for 3D pose estimation of the mobile-bearing insert used in TKA using X-ray fluoroscopy. The insert model was created using four identical tantalum beads precisely located at known positions in a polyethylene insert using a specially designed insertion device. Finally, the 3D pose of the insert model was estimated using a feature-based 2D/3D registration technique, using the silhouette of beads in fluoroscopic images and the corresponding CAD insert model. In vitro testing for the repeatability of the positioning of the tantalum beads and computer simulations for 3D pose estimation of the mobile-bearing insert were performed. The pose estimation accuracy achieved was sufficient for analyzing mobile-bearing TKA kinematics (RMS error: within 1.0 mm and 1.0°, except for medial-lateral translation). In a clinical application, nine patients with mobile-bearing TKA were investigated and analyzed with respect to a deep knee bending motion. A 3D kinematic analysis technique was developed that enables accurate quantitative evaluation of mobile-bearing TKA kinematics. This method may be useful for improving implant design and optimizing TKA surgical techniques.
Verification of Triple Modular Redundancy Insertion for Reliable and Trusted Systems
NASA Technical Reports Server (NTRS)
Berg, Melanie; LaBel, Kenneth
2016-01-01
If a system is required to be protected using triple modular redundancy (TMR), improper insertion can jeopardize the reliability and security of the system. Due to the complexity of the verification process and the complexity of digital designs, there are currently no available techniques that can provide complete and reliable confirmation of TMR insertion. We propose a method for TMR insertion verification that satisfies the process for reliable and trusted systems.
High-Throughput Analysis of T-DNA Location and Structure Using Sequence Capture.
Inagaki, Soichi; Henry, Isabelle M; Lieberman, Meric C; Comai, Luca
2015-01-01
Agrobacterium-mediated transformation of plants with T-DNA is used both to introduce transgenes and for mutagenesis. Conventional approaches used to identify the genomic location and the structure of the inserted T-DNA are laborious and high-throughput methods using next-generation sequencing are being developed to address these problems. Here, we present a cost-effective approach that uses sequence capture targeted to the T-DNA borders to select genomic DNA fragments containing T-DNA-genome junctions, followed by Illumina sequencing to determine the location and junction structure of T-DNA insertions. Multiple probes can be mixed so that transgenic lines transformed with different T-DNA types can be processed simultaneously, using a simple, index-based pooling approach. We also developed a simple bioinformatic tool to find sequence read pairs that span the junction between the genome and T-DNA or any foreign DNA. We analyzed 29 transgenic lines of Arabidopsis thaliana, each containing inserts from 4 different T-DNA vectors. We determined the location of T-DNA insertions in 22 lines, 4 of which carried multiple insertion sites. Additionally, our analysis uncovered a high frequency of unconventional and complex T-DNA insertions, highlighting the needs for high-throughput methods for T-DNA localization and structural characterization. Transgene insertion events have to be fully characterized prior to use as commercial products. Our method greatly facilitates the first step of this characterization of transgenic plants by providing an efficient screen for the selection of promising lines.
Miremad, Seyed Milad; Shirani, Babak
2018-06-01
In this paper, effective energy of pulsed X-Ray emitted from a Mather-type plasma focus device in stored energy of 2.5 kJ with six different anode's insert materials was measured using radiographic method with attenuation filters. Since intensity and energy of X-ray beam were considerably changed with changing the insert material, the method was improved by using different filters simultaneously in all the experiments and selection of the best filter in each experiment according to the appropriate criteria. Effective energy of pulsed X-ray beam was measured 16, 28, 50, 51, 34 and 44 keV when aluminum, copper, zinc, tin, tungsten and lead were used as insert materials, and aluminum, copper, silver, silver, copper and lead were used as filters, respectively. Copyright © 2018 Elsevier Ltd. All rights reserved.
Automated model-based quantitative analysis of phantoms with spherical inserts in FDG PET scans.
Ulrich, Ethan J; Sunderland, John J; Smith, Brian J; Mohiuddin, Imran; Parkhurst, Jessica; Plichta, Kristin A; Buatti, John M; Beichel, Reinhard R
2018-01-01
Quality control plays an increasingly important role in quantitative PET imaging and is typically performed using phantoms. The purpose of this work was to develop and validate a fully automated analysis method for two common PET/CT quality assurance phantoms: the NEMA NU-2 IQ and SNMMI/CTN oncology phantom. The algorithm was designed to only utilize the PET scan to enable the analysis of phantoms with thin-walled inserts. We introduce a model-based method for automated analysis of phantoms with spherical inserts. Models are first constructed for each type of phantom to be analyzed. A robust insert detection algorithm uses the model to locate all inserts inside the phantom. First, candidates for inserts are detected using a scale-space detection approach. Second, candidates are given an initial label using a score-based optimization algorithm. Third, a robust model fitting step aligns the phantom model to the initial labeling and fixes incorrect labels. Finally, the detected insert locations are refined and measurements are taken for each insert and several background regions. In addition, an approach for automated selection of NEMA and CTN phantom models is presented. The method was evaluated on a diverse set of 15 NEMA and 20 CTN phantom PET/CT scans. NEMA phantoms were filled with radioactive tracer solution at 9.7:1 activity ratio over background, and CTN phantoms were filled with 4:1 and 2:1 activity ratio over background. For quantitative evaluation, an independent reference standard was generated by two experts using PET/CT scans of the phantoms. In addition, the automated approach was compared against manual analysis, which represents the current clinical standard approach, of the PET phantom scans by four experts. The automated analysis method successfully detected and measured all inserts in all test phantom scans. It is a deterministic algorithm (zero variability), and the insert detection RMS error (i.e., bias) was 0.97, 1.12, and 1.48 mm for phantom activity ratios 9.7:1, 4:1, and 2:1, respectively. For all phantoms and at all contrast ratios, the average RMS error was found to be significantly lower for the proposed automated method compared to the manual analysis of the phantom scans. The uptake measurements produced by the automated method showed high correlation with the independent reference standard (R 2 ≥ 0.9987). In addition, the average computing time for the automated method was 30.6 s and was found to be significantly lower (P ≪ 0.001) compared to manual analysis (mean: 247.8 s). The proposed automated approach was found to have less error when measured against the independent reference than the manual approach. It can be easily adapted to other phantoms with spherical inserts. In addition, it eliminates inter- and intraoperator variability in PET phantom analysis and is significantly more time efficient, and therefore, represents a promising approach to facilitate and simplify PET standardization and harmonization efforts. © 2017 American Association of Physicists in Medicine.
2013-01-01
Background Persistent infection of Penaeus stylirostris densovirus (PstDNV) (also called IHHNV) and its non-infectious inserts in the black tiger shrimp, Penaeus monodon (P. monodon) genome are commonly found without apparent disease. Here, we introduced the method of multiplex PCR in order to differentiate shrimp with viral inserts from ones with the infectious virus. The method allowed us to study the effect of pre-infection of IHHNV, in comparison to IHHNV inserts, on WSSV resistance in P. monodon. Results A multiplex PCR system was developed to amplify the entire IHHNV genome, ensuring the accurate diagnosis. Field samples containing IHHNV DNA templates as low as 20 pg or equivalent 150 viral copies can be detected by this method. By challenging the two groups of diagnosed shrimp with WSSV, we found that shrimp with IHHNV infection and those with viral inserts responded to WSSV differently. Considering cumulative mortality, average time to death of shrimp in IHHNV-infected group (day 14) was significantly delayed relative to that (day 10) of IHHNV-inserted group. Real-time PCR analysis of WSSV copy number indicated the lower amount of WSSV in the IHHNV-infected group than the virus-inserted group. The ratio of IHHNV: WSSV copy number in all determined IHHNV-infected samples ranged from approximately 4 to 300-fold. Conclusion The multiplex PCR assay developed herein proved optimal for convenient differentiation of shrimp specimens with real IHHNV infection and those with insert types. Diagnosed shrimp were also found to exhibit different WSSV tolerance. After exposed to WSSV, the naturally pre-infected IHHNV P. monodon were less susceptible to WSSV and, consequently, survived longer than the IHHNV-inserted shrimp. PMID:23414329
Design and evaluation of moxifloxacin hydrochloride ocular inserts.
Pawar, Pravin K; Katara, Rajesh; Majumdar, Dipak K
2012-03-01
The objective of the present investigation was to prepare and evaluate ocular inserts of moxifloxacin. An ocular insert was made from an aqueous dispersion of moxifloxacin, sodium alginate, polyvinyl alcohol, and dibutyl phthalate by the film casting method. The ocular insert (5.5 mm diameter) was cross-linked by CaCl2 and was coated with Eudragit S-100, RL-100, RS-100, E-100 or L-100. The in vitro drug drainage/permeation studies were carried out using an all-glass modified Franz diffusion cell. The drug concentration and mucoadhesion time of the ocular insert were found satisfactory. Cross-linking and coating with polymers extended the drainage from inserts. The cross-linked ocular insert coated with Eudragit RL-100 showed maximum drug permeation compared to other formulations.
Soares, Marcelo Bento; Bonaldo, Maria de Fatima
1998-01-01
This invention provides a method to normalize a cDNA library comprising: (a) constructing a directionally cloned library containing cDNA inserts wherein the insert is capable of being amplified by polymerase chain reaction; (b) converting a double-stranded cDNA library into single-stranded DNA circles; (c) generating single-stranded nucleic acid molecules complementary to the single-stranded DNA circles converted in step (b) by polymerase chain reaction with appropriate primers; (d) hybridizing the single-stranded DNA circles converted in step (b) with the complementary single-stranded nucleic acid molecules generated in step (c) to produce partial duplexes to an appropriate Cot; and (e) separating the unhybridized single-stranded DNA circles from the hybridized DNA circles, thereby generating a normalized cDNA library. This invention also provides a method to normalize a cDNA library wherein the generating of single-stranded nucleic acid molecules complementary to the single-stranded DNA circles converted in step (b) is by excising cDNA inserts from the double-stranded cDNA library; purifying the cDNA inserts from cloning vectors; and digesting the cDNA inserts with an exonuclease. This invention further provides a method to construct a subtractive cDNA library following the steps described above. This invention further provides normalized and/or subtractive cDNA libraries generated by the above methods.
Soares, M.B.; Fatima Bonaldo, M. de
1998-12-08
This invention provides a method to normalize a cDNA library comprising: (a) constructing a directionally cloned library containing cDNA inserts wherein the insert is capable of being amplified by polymerase chain reaction; (b) converting a double-stranded cDNA library into single-stranded DNA circles; (c) generating single-stranded nucleic acid molecules complementary to the single-stranded DNA circles converted in step (b) by polymerase chain reaction with appropriate primers; (d) hybridizing the single-stranded DNA circles converted in step (b) with the complementary single-stranded nucleic acid molecules generated in step (c) to produce partial duplexes to an appropriate Cot; and (e) separating the unhybridized single-stranded DNA circles from the hybridized DNA circles, thereby generating a normalized cDNA library. This invention also provides a method to normalize a cDNA library wherein the generating of single-stranded nucleic acid molecules complementary to the single-stranded DNA circles converted in step (b) is by excising cDNA inserts from the double-stranded cDNA library; purifying the cDNA inserts from cloning vectors; and digesting the cDNA inserts with an exonuclease. This invention further provides a method to construct a subtractive cDNA library following the steps described above. This invention further provides normalized and/or subtractive cDNA libraries generated by the above methods. 25 figs.
Bakker, Theo C M; Giger, Thomas; Frommen, Joachim G; Largiadèr, Carlo R
2017-08-01
There is a need for rapid and reliable molecular sexing of three-spined sticklebacks, Gasterosteus aculeatus, the supermodel species for evolutionary biology. A DNA region at the 5' end of the sex-linked microsatellite Gac4202 was sequenced for the X chromosome of six females and the Y chromosome of five males from three populations. The Y chromosome contained two large insertions, which did not recombine with the phenotype of sex in a cross of 322 individuals. Genetic variation (SNPs and indels) within the insertions was smaller than on flanking DNA sequences. Three molecular PCR-based sex tests were developed, in which the first, the second or both insertions were covered. In five European populations (from DE, CH, NL, GB) of three-spined sticklebacks, tests with both insertions combined showed two clearly separated bands on agarose minigels in males and one band in females. The tests with the separate insertions gave similar results. Thus, the new molecular sexing method gave rapid and reliable results for sexing three-spined sticklebacks and is an improvement and/or alternative to existing methods.
EUVL back-insertion layout optimization
NASA Astrophysics Data System (ADS)
Civay, D.; Laffosse, E.; Chesneau, A.
2018-03-01
Extreme ultraviolet lithography (EUVL) is targeted for front-up insertion at advanced technology nodes but will be evaluated for back insertion at more mature nodes. EUVL can put two or more mask levels back on one mask, depending upon what level(s) in the process insertion occurs. In this paper, layout optimization methods are discussed that can be implemented when EUVL back insertion is implemented. The layout optimizations can be focused on improving yield, reliability or density, depending upon the design needs. The proposed methodology modifies the original two or more colored layers and generates an optimized single color EUVL layout design.
2013-03-01
Weave Welding Method Wheel Assembly Wind Load Wind Loads Wind Uplift Resistance Wind Uplift Resistance Class Window Category Window Finish Window... wind - blast Elongation UFGS 2.1 percent Insert Value Visual Defects UFGS 2.1 n/a Insert Value ERDC/CERL CR-13-1 39 Attribute Source...Sustainability COBie Guide n/a insert reqts FRP Strengthening UFGS 1.2 n/a seismic - wind - blast Elongation UFGS 2.2 percent Insert Value Tensile
Ulrich, Alexander; Andersen, Kasper R.; Schwartz, Thomas U.
2012-01-01
We present a fast, reliable and inexpensive restriction-free cloning method for seamless DNA insertion into any plasmid without sequence limitation. Exponential megapriming PCR (EMP) cloning requires two consecutive PCR steps and can be carried out in one day. We show that EMP cloning has a higher efficiency than restriction-free (RF) cloning, especially for long inserts above 2.5 kb. EMP further enables simultaneous cloning of multiple inserts. PMID:23300917
Ulrich, Alexander; Andersen, Kasper R; Schwartz, Thomas U
2012-01-01
We present a fast, reliable and inexpensive restriction-free cloning method for seamless DNA insertion into any plasmid without sequence limitation. Exponential megapriming PCR (EMP) cloning requires two consecutive PCR steps and can be carried out in one day. We show that EMP cloning has a higher efficiency than restriction-free (RF) cloning, especially for long inserts above 2.5 kb. EMP further enables simultaneous cloning of multiple inserts.
Modified Peritoneal Dialysis Catheter Insertion: Comparison with a Conventional Method
Lee, Yong Kyu; Yang, Pil-Sung; Park, Kyoung Sook; Choi, Kyu Hun
2015-01-01
Purpose The conventional trocar and cannula method in peritoneal dialysis (PD) catheter insertion has its limitation in clinical setting. The aim of this study was to compare a modified method for percutaneous PD catheter insertion with the conventional method, and demonstrate advantages of the modified method. Materials and Methods Patients at a single center who had percutaneous PD catheters inserted by nephrologists from January 2006 until September 2012, using either a modified method (group M) or the conventional trocar and cannula method (group C), were retrospectively analyzed, in terms of baseline characteristics, complications experienced up to 3 months after the procedure, and the suitability of the procedure for patients. Results Group M included 82 subjects, while group C included 66 cases. The overall early complication rate in group M (1.2%) was significantly lower than that in group C (19.7%) (p<0.001). The catheter revision rate during timeframe for early complications was significantly lower in group M (0%) than in group C (6.1%) (p=0.024). When comparing Procedure time (1 h 3 min±16 min vs. 1 h 36 min±19 min, p<0.01), immediate post-procedural pain (2.43±1.80 vs. 3.14±2.07, p<0.05), and post-procedure days until ambulation (3.95±1.13 days vs. 6.17±1.34 days, p<0.01), group M was significantly lower than group C. There was no significant difference in total hospitalization period (14.71±7.05 days vs. 13.86±3.7 days). Conclusion Our modified PD catheter insertion method shows its advantages in early complication rate, early complications revision rate, and the patients' conveniences. PMID:26069120
The Direct Insertion of the ACL Carries More Load than the Indirect Insertion
Nawabi, Danyal H.; Tucker, Scott; Jones, Kristofer J.; Nguyen, Joseph; Wickiewicz, Thomas L.; Imhauser, Carl; Pearle, Andrew
2014-01-01
Objectives: Recent histological studies have shown that the ACL consists of two different structures: the direct and indirect insertions. The direct insertion is located along the lateral intercondylar ridge and the indirect insertion is ‘lower’ in the notch, adjacent to the posterior articular cartilage. The ‘lower’ position has become more popular for locating the femoral tunnel, as surgeons switch to the anteromedial (AM) portal drilling technique in order to place the graft in the region of the native footprint. However, a recent registry-based outcomes study has reported a 1.5 times higher graft failure rate for AM portal versus traditional transtibial techniques. The objective of this study was to investigate the load characteristics of the native ACL in the regions of the direct and indirect insertions. We hypothesized that the direct insertion would carry more load than the indirect insertion. Methods: Twelve cadaveric knees were mounted to a six degree of freedom robot equipped with a universal force-moment sensor. We simulated the Lachman and anterior drawer tests at 30oand 90o of flexion by applying a 134N anterior load, and the pivot shift test at 15o flexion by applying combined valgus (8Nm) and internal (4Nm) rotational moments. The kinematic pathway required to achieve these loading conditions was recorded for each intact knee. Using position control to repeat the loading paths, the robot recorded the loads for the ACL intact, ACL partially sectioned, and ACL completely sectioned states. Sectioning Protocol: The lateral intercondylar ridge and posterior articular margin was identified in each case. The 50% mark between this two areas was used to delineate the regions of the direct and indirect insertions (Fig. 1). Sectioning order was alternated between each cadaver. Footprint Digitization: The borders of the sectioned areas were digitized post-sectioning and mapped onto a computed tomography (CT) scan of each knee. The sectioning method was assessed under a blinded validation by experienced observers (TW, AP) who excluded two specimens that did not conform to the objective definitions of the sectioning method. Statistics: Loads were compared between direct and indirect locations at different flexion angles by conducting two-way repeated measures ANOVA models. Results: Under an anterior tibial load at 30o flexion, the direct insertion carried 83.9% (±7.2%) of the total ACL load compared to 16.1% (±7.2%) in the indirect insertion (p<0.001). The direct insertion also carried more load at 90o flexion (95.2% vs 4.8%; p<0.001). Under a combined rotatory load at 15o flexion, the direct insertion carried 84.2% (±4.2%)of the total ACL load compared to 15.8% (±4.2%) in the indirect insertion (p<0.001). Conclusion: The fibres in the direct insertion of the ACL carry more load than fibres in the indirect insertion. Previous studies have suggested that the direct insertion plays a major role in the mechanical link between the ACL and bone. With the current shift in emphasis towards anatomic ACL reconstruction, it may be beneficial to create the femoral tunnel within the direct insertion rather than ‘lower’ in the notch. Although further work is required in determining graft behaviour at the new insertions sites described in this study, our findings suggest that placing a graft in the region of the direct insertion may be an important consideration when adhering to the principles of anatomic ACL reconstruction.
Technical note: Computer-manufactured inserts for prosthetic sockets.
Sanders, Joan E; McLean, Jake B; Cagle, John C; Gardner, David W; Allyn, Katheryn J
2016-08-01
The objective of this research was to use computer-aided design software and a tabletop 3-D additive manufacturing system to design and fabricate custom plastic inserts for trans-tibial prosthesis users. Shape quality of inserts was tested right after they were inserted into participant's test sockets and again after four weeks of wear. Inserts remained properly positioned and intact throughout testing. Right after insertion the inserts caused the socket to be slightly under-sized, by a mean of 0.11mm, approximately 55% of the thickness of a nylon sheath. After four weeks of wear the under-sizing was less, averaging 0.03mm, approximately 15% of the thickness of a nylon sheath. Thus the inserts settled into the sockets over time. If existing prosthetic design software packages were enhanced to conduct insert design and to automatically generate fabrication files for manufacturing, then computer manufactured inserts may offer advantages over traditional methods in terms of speed of fabrication, ease of design, modification, and record keeping. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.
Lebard, David N; Matyushov, Dmitry V
2008-12-01
Molecular dynamics simulations have revealed a dramatic increase, with increasing temperature, of the amplitude of electrostatic fluctuations caused by water at the active site of metalloprotein plastocyanin. The increased breadth of electrostatic fluctuations, expressed in terms of the reorganization energy of changing the redox state of the protein, is related to the formation of the hydrophobic protein-water interface, allowing large-amplitude collective fluctuations of the water density in the protein's first solvation shell. On top of the monotonic increase of the reorganization energy with increasing temperature, we have observed a spike at approximately 220 K also accompanied by a significant slowing of the exponential collective Stokes shift dynamics. In contrast to the local density fluctuations of the hydration-shell waters, these spikes might be related to the global property of the water solvent crossing the Widom line or undergoing a weak first-order transition.
NASA Astrophysics Data System (ADS)
Ito, Yasufumi; Takeuchi, Kazumasa A.
2018-04-01
We study height fluctuations of interfaces in the (1 +1 ) -dimensional Kardar-Parisi-Zhang (KPZ) class, growing at different speeds in the left half and the right half of space. Carrying out simulations of the discrete polynuclear growth model with two different growth rates, combined with the standard setting for the droplet, flat, and stationary geometries, we find that the fluctuation properties at and near the boundary are described by the KPZ half-space problem developed in the theoretical literature. In particular, in the droplet case, the distribution at the boundary is given by the largest-eigenvalue distribution of random matrices in the Gaussian symplectic ensemble, often called the GSE Tracy-Widom distribution. We also characterize crossover from the full-space statistics to the half-space one, which arises when the difference between the two growth speeds is small.
High-throughput analysis of T-DNA location and structure using sequence capture
DOE Office of Scientific and Technical Information (OSTI.GOV)
Inagaki, Soichi; Henry, Isabelle M.; Lieberman, Meric C.
Agrobacterium-mediated transformation of plants with T-DNA is used both to introduce transgenes and for mutagenesis. Conventional approaches used to identify the genomic location and the structure of the inserted T-DNA are laborious and high-throughput methods using next-generation sequencing are being developed to address these problems. Here, we present a cost-effective approach that uses sequence capture targeted to the T-DNA borders to select genomic DNA fragments containing T-DNA—genome junctions, followed by Illumina sequencing to determine the location and junction structure of T-DNA insertions. Multiple probes can be mixed so that transgenic lines transformed with different T-DNA types can be processed simultaneously,more » using a simple, index-based pooling approach. We also developed a simple bioinformatic tool to find sequence read pairs that span the junction between the genome and T-DNA or any foreign DNA. We analyzed 29 transgenic lines of Arabidopsis thaliana, each containing inserts from 4 different T-DNA vectors. We determined the location of T-DNA insertions in 22 lines, 4 of which carried multiple insertion sites. Additionally, our analysis uncovered a high frequency of unconventional and complex T-DNA insertions, highlighting the needs for high-throughput methods for T-DNA localization and structural characterization. Transgene insertion events have to be fully characterized prior to use as commercial products. As a result, our method greatly facilitates the first step of this characterization of transgenic plants by providing an efficient screen for the selection of promising lines.« less
High-throughput analysis of T-DNA location and structure using sequence capture
Inagaki, Soichi; Henry, Isabelle M.; Lieberman, Meric C.; ...
2015-10-07
Agrobacterium-mediated transformation of plants with T-DNA is used both to introduce transgenes and for mutagenesis. Conventional approaches used to identify the genomic location and the structure of the inserted T-DNA are laborious and high-throughput methods using next-generation sequencing are being developed to address these problems. Here, we present a cost-effective approach that uses sequence capture targeted to the T-DNA borders to select genomic DNA fragments containing T-DNA—genome junctions, followed by Illumina sequencing to determine the location and junction structure of T-DNA insertions. Multiple probes can be mixed so that transgenic lines transformed with different T-DNA types can be processed simultaneously,more » using a simple, index-based pooling approach. We also developed a simple bioinformatic tool to find sequence read pairs that span the junction between the genome and T-DNA or any foreign DNA. We analyzed 29 transgenic lines of Arabidopsis thaliana, each containing inserts from 4 different T-DNA vectors. We determined the location of T-DNA insertions in 22 lines, 4 of which carried multiple insertion sites. Additionally, our analysis uncovered a high frequency of unconventional and complex T-DNA insertions, highlighting the needs for high-throughput methods for T-DNA localization and structural characterization. Transgene insertion events have to be fully characterized prior to use as commercial products. As a result, our method greatly facilitates the first step of this characterization of transgenic plants by providing an efficient screen for the selection of promising lines.« less
Kuhn, Alexandre; Ong, Yao Min; Quake, Stephen R; Burkholder, William F
2015-07-08
Like other structural variants, transposable element insertions can be highly polymorphic across individuals. Their functional impact, however, remains poorly understood. Current genome-wide approaches for genotyping insertion-site polymorphisms based on targeted or whole-genome sequencing remain very expensive and can lack accuracy, hence new large-scale genotyping methods are needed. We describe a high-throughput method for genotyping transposable element insertions and other types of structural variants that can be assayed by breakpoint PCR. The method relies on next-generation sequencing of multiplex, site-specific PCR amplification products and read count-based genotype calls. We show that this method is flexible, efficient (it does not require rounds of optimization), cost-effective and highly accurate. This method can benefit a wide range of applications from the routine genotyping of animal and plant populations to the functional study of structural variants in humans.
Gas turbine nozzle vane insert and methods of installation
Miller, William John; Predmore, Daniel Ross; Placko, James Michael
2002-01-01
A pair of hollow elongated insert bodies are disposed in one or more of the nozzle vane cavities of a nozzle stage of a gas turbine. Each insert body has an outer wall portion with apertures for impingement-cooling of nozzle wall portions in registration with the outer wall portion. The insert bodies are installed into the cavity separately and spreaders flex the bodies toward and to engage standoffs against wall portions of the nozzle whereby the designed impingement gap between the outer wall portions of the insert bodies and the nozzle wall portions is achieved. The spreaders are secured to the inner wall portions of the insert bodies and the bodies are secured to one another and to the nozzle vane by welding or brazing.
Harker, JO; Leung, JW; Siao-Salera, RM; Mann, SK; Ramirez, FC; Friedland, S; Amato, A; Radaelli, F; Paggi, S; Terruzzi, V; Hsieh, YH
2011-01-01
Introduction Variation in the outcomes in RcTs comparing water-related methods and air insufflation during the insertion phase of colonoscopy raises challenging questions regarding the approach. This report reviews the impact of water exchange on the variation in attenuation of pain during colonoscopy by water-related methods. Methods Medline (2008 to 2011) searches, abstracts of the 2011 Digestive Disease Week (DDW) and personal communications were considered to identify RcTs that compared water-related methods and air insufflation to aid insertion of the colonoscope. Results: Since 2008 nine published and one submitted RcTs and five abstracts of RcTs presented at the 2011 DDW have been identified. Thirteen RcTs (nine published, one submitted and one abstract, n=1850) described reduction of pain score during or after colonoscopy (eleven reported statistical significance); the remaining reports described lower doses of medication used, or lower proportion of patients experiencing severe pain in colonoscopy performed with water-related methods compared with air insufflation (Tables 1 and 2). The water-related methods notably differ in the timing of removal of the infused water - predominantly during insertion (water exchange) versus predominantly during withdrawal (water immersion). Use of water exchange was consistently associated with a greater attenuation of pain score in patients who did not receive full sedation (Table 3). Conclusion The comparative data reveal that a greater attenuation of pain was associated with water exchange than water immersion during insertion. The intriguing results should be subjected to further evaluation by additional RcTs to elucidate the mechanism of the pain-alleviating impact of the water method. PMID:22163081
Modified Peritoneal Dialysis Catheter Insertion: Comparison with a Conventional Method.
Lee, Yong Kyu; Yang, Pil-Sung; Park, Kyoung Sook; Choi, Kyu Hun; Kim, Beom Seok
2015-07-01
The conventional trocar and cannula method in peritoneal dialysis (PD) catheter insertion has its limitation in clinical setting. The aim of this study was to compare a modified method for percutaneous PD catheter insertion with the conventional method, and demonstrate advantages of the modified method. Patients at a single center who had percutaneous PD catheters inserted by nephrologists from January 2006 until September 2012, using either a modified method (group M) or the conventional trocar and cannula method (group C), were retrospectively analyzed, in terms of baseline characteristics, complications experienced up to 3 months after the procedure, and the suitability of the procedure for patients. Group M included 82 subjects, while group C included 66 cases. The overall early complication rate in group M (1.2%) was significantly lower than that in group C (19.7%) (p<0.001). The catheter revision rate during timeframe for early complications was significantly lower in group M (0%) than in group C (6.1%) (p=0.024). When comparing Procedure time (1 h 3 min±16 min vs. 1 h 36 min±19 min, p<0.01), immediate post-procedural pain (2.43±1.80 vs. 3.14±2.07, p<0.05), and post-procedure days until ambulation (3.95±1.13 days vs. 6.17±1.34 days, p<0.01), group M was significantly lower than group C. There was no significant difference in total hospitalization period (14.71±7.05 days vs. 13.86±3.7 days). Our modified PD catheter insertion method shows its advantages in early complication rate, early complications revision rate, and the patients' conveniences.
Validation of an improved abnormality insertion method for medical image perception investigations
NASA Astrophysics Data System (ADS)
Madsen, Mark T.; Durst, Gregory R.; Caldwell, Robert T.; Schartz, Kevin M.; Thompson, Brad H.; Berbaum, Kevin S.
2009-02-01
The ability to insert abnormalities in clinical tomographic images makes image perception studies with medical images practical. We describe a new insertion technique and its experimental validation that uses complementary image masks to select an abnormality from a library and place it at a desired location. The method was validated using a 4-alternative forced-choice experiment. For each case, four quadrants were simultaneously displayed consisting of 5 consecutive frames of a chest CT with a pulmonary nodule. One quadrant was unaltered, while the other 3 had the nodule from the unaltered quadrant artificially inserted. 26 different sets were generated and repeated with order scrambling for a total of 52 cases. The cases were viewed by radiology staff and residents who ranked each quadrant by realistic appearance. On average, the observers were able to correctly identify the unaltered quadrant in 42% of cases, and identify the unaltered quadrant both times it appeared in 25% of cases. Consensus, defined by a majority of readers, correctly identified the unaltered quadrant in only 29% of 52 cases. For repeats, the consensus observer successfully identified the unaltered quadrant only once. We conclude that the insertion method can be used to reliably place abnormalities in perception experiments.
Lesion insertion in the projection domain: Methods and initial results
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Baiyu; Leng, Shuai; Yu, Lifeng
2015-12-15
Purpose: To perform task-based image quality assessment in CT, it is desirable to have a large number of realistic patient images with known diagnostic truth. One effective way of achieving this objective is to create hybrid images that combine patient images with inserted lesions. Because conventional hybrid images generated in the image domain fails to reflect the impact of scan and reconstruction parameters on lesion appearance, this study explored a projection-domain approach. Methods: Lesions were segmented from patient images and forward projected to acquire lesion projections. The forward-projection geometry was designed according to a commercial CT scanner and accommodated bothmore » axial and helical modes with various focal spot movement patterns. The energy employed by the commercial CT scanner for beam hardening correction was measured and used for the forward projection. The lesion projections were inserted into patient projections decoded from commercial CT projection data. The combined projections were formatted to match those of commercial CT raw data, loaded onto a commercial CT scanner, and reconstructed to create the hybrid images. Two validations were performed. First, to validate the accuracy of the forward-projection geometry, images were reconstructed from the forward projections of a virtual ACR phantom and compared to physically acquired ACR phantom images in terms of CT number accuracy and high-contrast resolution. Second, to validate the realism of the lesion in hybrid images, liver lesions were segmented from patient images and inserted back into the same patients, each at a new location specified by a radiologist. The inserted lesions were compared to the original lesions and visually assessed for realism by two experienced radiologists in a blinded fashion. Results: For the validation of the forward-projection geometry, the images reconstructed from the forward projections of the virtual ACR phantom were consistent with the images physically acquired for the ACR phantom in terms of Hounsfield unit and high-contrast resolution. For the validation of the lesion realism, lesions of various types were successfully inserted, including well circumscribed and invasive lesions, homogeneous and heterogeneous lesions, high-contrast and low-contrast lesions, isolated and vessel-attached lesions, and small and large lesions. The two experienced radiologists who reviewed the original and inserted lesions could not identify the lesions that were inserted. The same lesion, when inserted into the projection domain and reconstructed with different parameters, demonstrated a parameter-dependent appearance. Conclusions: A framework has been developed for projection-domain insertion of lesions into commercial CT images, which can be potentially expanded to all geometries of CT scanners. Compared to conventional image-domain methods, the authors’ method reflected the impact of scan and reconstruction parameters on lesion appearance. Compared to prior projection-domain methods, the authors’ method has the potential to achieve higher anatomical complexity by employing clinical patient projections and real patient lesions.« less
Lesion insertion in the projection domain: Methods and initial results
Chen, Baiyu; Leng, Shuai; Yu, Lifeng; Yu, Zhicong; Ma, Chi; McCollough, Cynthia
2015-01-01
Purpose: To perform task-based image quality assessment in CT, it is desirable to have a large number of realistic patient images with known diagnostic truth. One effective way of achieving this objective is to create hybrid images that combine patient images with inserted lesions. Because conventional hybrid images generated in the image domain fails to reflect the impact of scan and reconstruction parameters on lesion appearance, this study explored a projection-domain approach. Methods: Lesions were segmented from patient images and forward projected to acquire lesion projections. The forward-projection geometry was designed according to a commercial CT scanner and accommodated both axial and helical modes with various focal spot movement patterns. The energy employed by the commercial CT scanner for beam hardening correction was measured and used for the forward projection. The lesion projections were inserted into patient projections decoded from commercial CT projection data. The combined projections were formatted to match those of commercial CT raw data, loaded onto a commercial CT scanner, and reconstructed to create the hybrid images. Two validations were performed. First, to validate the accuracy of the forward-projection geometry, images were reconstructed from the forward projections of a virtual ACR phantom and compared to physically acquired ACR phantom images in terms of CT number accuracy and high-contrast resolution. Second, to validate the realism of the lesion in hybrid images, liver lesions were segmented from patient images and inserted back into the same patients, each at a new location specified by a radiologist. The inserted lesions were compared to the original lesions and visually assessed for realism by two experienced radiologists in a blinded fashion. Results: For the validation of the forward-projection geometry, the images reconstructed from the forward projections of the virtual ACR phantom were consistent with the images physically acquired for the ACR phantom in terms of Hounsfield unit and high-contrast resolution. For the validation of the lesion realism, lesions of various types were successfully inserted, including well circumscribed and invasive lesions, homogeneous and heterogeneous lesions, high-contrast and low-contrast lesions, isolated and vessel-attached lesions, and small and large lesions. The two experienced radiologists who reviewed the original and inserted lesions could not identify the lesions that were inserted. The same lesion, when inserted into the projection domain and reconstructed with different parameters, demonstrated a parameter-dependent appearance. Conclusions: A framework has been developed for projection-domain insertion of lesions into commercial CT images, which can be potentially expanded to all geometries of CT scanners. Compared to conventional image-domain methods, the authors’ method reflected the impact of scan and reconstruction parameters on lesion appearance. Compared to prior projection-domain methods, the authors’ method has the potential to achieve higher anatomical complexity by employing clinical patient projections and real patient lesions. PMID:26632058
Rectal suppository insertion: the reliability of the evidence as a basis for nursing practice.
Bradshaw, Ann; Price, Lynda
2007-01-01
This paper considers the correct method for inserting a rectal suppository, both as a medication and also to achieve bowel evacuation. The aim is to find out whether the correct method is blunt end or pointed end foremost. It follows from a question raised by a third year student nurse. In the classroom, she had been taught that the correct method for the administration of a suppository for systemic absorption was to insert it blunt end foremost into the rectum. However, if the suppository was to be used for evacuant purposes, it should be given pointed end foremost. In clinical practice, however, she was told the suppository should always be inserted pointed end foremost in all cases, whatever the purpose. This article seeks to clarify the dilemma by examining the sources of evidence underpinning different methods for inserting a rectal suppository. Hence, the literature on the insertion of rectal suppositories was gathered as systematically as possible from medical journals and textbooks, nursing journals and textbooks and manufacturers' information to patients. Having gathered the literature, this was examined, appraised and critically analysed for rigour, coherence and reliability. The review of the literature appears to show that evidence adduced for inserting the suppository blunt end foremost derives from one study published in the Lancet in 1991, which challenged 'commonsense'. There did not appear to be other, more recent research. On the other hand, manufacturers' information to patients states generally that the suppository should be inserted pointed end foremost. This has direct relevance for the administration of suppositories and also raises questions as to how research may become integrated into healthcare practice without adequate justification. An article published in the Lancet in 1991 has had a fundamental effect on nursing practice, but has not been subject to scrutiny. The advice given in this Lancet article differs from that currently given by most manufacturers of suppositories, which involves the terms of their product licence. Hence, there is a potential for problems with legal liability should an untoward event arise. Inserting rectal suppositories, whether as a medication or to achieve bowel evacuation, is a very common healthcare practice. Currently, there is inconsistency and discrepancy in the correct method for this procedure in both nursing education and practice. This paper examines the reliability of existing evidence and shows the need for further work in order to provide a reliable evidence base for this commonplace clinical procedure.
A simple method of measuring the wear of explanted acetabular component inserts
Krakow, L.; Klockow, A.; Roehner, E.; Brodt, S.; Eijer, H.; Bossert, J.
2017-01-01
Objectives The determination of the volumetric polyethylene wear on explanted material requires complicated equipment, which is not available in many research institutions. Our aim in this study was to present and validate a method that only requires a set of polyetheretherketone balls and a laboratory balance to determine wear. Methods The insert to be measured was placed on a balance, and a ball of the appropriate diameter was inserted. The cavity remaining between the ball and insert caused by wear was filled with contrast medium and the weight of the contrast medium was recorded. The volume was calculated from the known density of the liquid. The precision, inter- and intraobserver reliability, were determined by four investigators on four days using nine inserts with specified wear (0.094 ml to 1.626 ml), and the intra-class correlation coefficient was calculated. The feasibility of using this method in routine clinical practice and the time required for measurement were tested on 84 explanted inserts by one investigator. Results In order to get the mean for all investigators and determinations, the deviation between the measured and specified wear was -0.08 ml (sd 0.12; -0.21 to 0.11). The interobserver reliability was 0.989 ml (95% confidence interval (CI) 0.964 to 0.997) and the intraobserver reliability was 0.941 for observer 1 (95% CI 0.846 to 0.985), 0.983 for observer 2 (95% CI 0.956 to 0.995), 0.939 for observer 3 (95% CI 0.855 to 0.984), and 0.934 for observer 4 (95% CI 0.790 to 0.984). The mean time required to examine the samples was two minutes (sd 2; 1 to 5). Conclusion The method presented here was shown to be sufficiently precise for many settings and is a cost-effective and quick method of determining the volumetric wear of explanted acetabular components. However, the measurement of wear for scientific purposes will probably continue to involve more accurate and dedicated laboratory equipment. Cite this article: L. Krakow, A. Klockow, E. Roehner, S. Brodt, H. Eijer, J. Bossert, G. Matziolis. A simple method of measuring the wear of explanted acetabular component inserts. Bone Joint Res 2017;6:530–534. DOI: 10.1302/2046-3758.69.BJR-2016-0249.R1 PMID:28899855
Kratchman, Louis B.; Schurzig, Daniel; McRackan, Theodore R.; Balachandran, Ramya; Noble, Jack H.; Webster, Robert J.; Labadie, Robert F.
2014-01-01
The current technique for cochlear implantation (CI) surgery requires a mastoidectomy to gain access to the cochlea for electrode array insertion. It has been shown that microstereotactic frames can enable an image-guided, minimally invasive approach to CI surgery called percutaneous cochlear implantation (PCI) that uses a single drill hole for electrode array insertion, avoiding a more invasive mastoidectomy. Current clinical methods for electrode array insertion are not compatible with PCI surgery because they require a mastoidectomy to access the cochlea; thus, we have developed a manually operated electrode array insertion tool that can be deployed through a PCI drill hole. The tool can be adjusted using a preoperative CT scan for accurate execution of the advance off-stylet (AOS) insertion technique and requires less skill to operate than is currently required to implant electrode arrays. We performed three cadaver insertion experiments using the AOS technique and determined that all insertions were successful using CT and microdissection. PMID:22851233
Vachhani, Raj; Patel, Toral; Centor, Robert M; Estrada, Carlos A
2017-01-01
Meta-analyses based on peer-reviewed publications report a sensitivity of approximately 85% for rapid antigen streptococcus tests to diagnose group A streptococcal (GAS) pharyngitis. Because these meta-analyses excluded package inserts, we examined the test characteristics of rapid antigen streptococcal tests and molecular methods that manufacturers report in their package inserts. We included tests available in the US market (Food and Drug Administration, period searched 1993-2015) and used package insert data to calculate pooled sensitivity and specificity. To examine quality, we used the Quality Assessment of Diagnostic Accuracy Studies-2. We excluded 26 tests having different trade names but identical methods and data. The study design was prospective in 41.7% (10 of 24). The pooled sensitivity of the most commonly used method, lateral flow/immunochromatographic, was 95% (95% confidence interval [CI] 94-96) and the pooled specificity was 98% (96-98); 7108 patients. The pooled sensitivity of the polymerase chain reaction or molecular methods was 98% (95% CI 96-98) and the pooled specificity was 96% (95% CI 95-97); 5685 patients. Package inserts include sponsored studies that overestimate the sensitivity of rapid tests to diagnose GAS pharyngitis by approximately 10%. Physicians should understand that package inserts overestimate diagnostic test utility; a negative test cannot be used to exclude GAS pharyngitis.
Fabrication of robust tooling for mass production of polymeric microfluidic devices
NASA Astrophysics Data System (ADS)
Fu, G.; Tor, S. B.; Loh, N. H.; Hardt, D. E.
2010-08-01
Polymer microfluidic devices are gaining popularity for bio-applications. In both commonly used methods for the fabrication of polymer microfluidic devices, i.e. injection molding and hot-embossing, the quality of a mold insert is of high importance. Micro powder injection molding (μPIM) provides a suitable option for metal mold insert fabrication. In this paper, two mold inserts with micro-features of different patterns and sizes were produced using 316L stainless steel powder and an in-house binder system. The mold inserts were successfully used to produce cyclic olefin copolymer (COC, trade name TOPAS) micromixer plates with micro-channels of widths 100 µm and 50 µm. Compared with CNC-machined hot work steel mold inserts, the quality of the micro-channels is better as far as geometrical quality and dimensional tolerance are concerned. However, surface finish and flatness of the μPIM mold inserts are inferior to those of CNC-machined mold inserts.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ferrero, A; Chen, B; Huang, A
Purpose: In order to investigate novel methods to more accurately estimate the mineral composition of kidney stones using dual energy CT, it is desirable to be able to combine digital stones of known composition with actual phantom and patient scan data. In this work, we developed and validated a method to insert digital kidney stones into projection data acquired on a dual-source, dual-energy CT system. Methods: Attenuation properties of stones of different mineral composition were computed using tabulated mass attenuation coefficients, the chemical formula for each stone type, and the effective beam energy at each evaluated tube potential. A previouslymore » developed method to insert lesions into x-ray CT projection data was extended to include simultaneous dual-energy CT projections acquired on a dual-source gantry (Siemens Somatom Flash). Digital stones were forward projected onto both detectors and the resulting projections added to the physically acquired sinogram data. To validate the accuracy of the technique, digital stones were inserted into different locations in the ACR CT accreditation phantom; low and high contrast resolution, CT number accuracy and noise properties were compared before and after stone insertion. The procedure was repeated for two dual-energy tube potential pairs in clinical use on the scanner, 80/Sn140 kV and 100/Sn140 kV, respectively. Results: The images reconstructed after the insertion of digital kidney stones were consistent with the images reconstructed from the scanner. The largest average CT number difference for the 4 insert in the CT number accuracy module of the phantom was 3 HU. Conclusion: A framework was developed and validated for the creation of digital kidney stones of known mineral composition, and their projection-domain insertion into commercial dual-source, dual-energy CT projection data. This will allow a systematic investigation of the impact of scan and reconstruction parameters on stone attenuation and dual-energy behavior under rigorously controlled conditions. Dr. McCollough receives research support from Siemens Healthcare.« less
Harker, JO; Leung, JW; Siao-Salera, RM; Mann, SK; Ramirez, FC; Friedland, S; Amato, A; Radaelli, F; Paggi, S; Terruzzi, V; Hsieh, YH
2011-01-01
Introduction Variation in outcomes in RcTs comparing water-related methods and air insufflation raises challenging questions regarding the new approach. This report reviews impact of water exchange - simultaneous infusion and removal of infused water during insertion on adenoma detection rate (ADR) defined as proportion of patients with a least one adenoma of any size. Methods Medline (2008–2011) searches, abstract of 2011 Digestive Disease Week (DDW) meeting and personal communications were considered to identify RcTs that compared water-related methods and air insufflation to aid insertion of colonoscope. Results Since 2008, eleven reports of RcTs (6 published, 1 submitted and 4 abstracts, n=1728) described ADR in patients randomized to be examined by air and water-related methods. The water-related methods differed in timing of removal of the infused water -predominantly during insertion (water exchange) (n=825) or predominantly during withdrawal (water immersion) (n=903). Water immersion was associated with both increases and decreases in ADR compared to respective air method patients and the net overall change (-7%) was significant. On the other hand water exchange was associated with increases in ADR consistently and the net changes (overall, 8%; proximal overall, 11%; and proximal <10 mm, 12%) were all significant. Conclusion Comparative data generated the hypothesis that significantly larger increases in overall and proximal colon ADRs were associated with water exchange than water immersion or air insufflation during insertion. The hypothesis should be evaluated by RCTs to elucidate the mechanism of water exchange on adenoma detection. PMID:22163082
Shielding methods of quasilaminar jets outflowing from plasma torch with interelectrode insert
NASA Astrophysics Data System (ADS)
Solonenko, O. P.; Smirnov, A. V.
2017-05-01
Investigations of two methods of protection against mixing of surrounding air atmosphere with the free lengthy jets outflowing at low Reynolds numbers from plasma torches with interelectrode insertion (IEI) were carried out. The offered methods allow to significantly reduce the mixing of oxygen with plasma jets that gives a possibility of synthesis, treatment and spraying of powder materials, as well as melting of coatings critical to oxidation.
Shiba, N; Kitaoka, H B; Cahalan, T D; Chao, E Y
1995-01-01
The efficacy of 3 shock-absorbing materials was compared by determining impact characteristics with a drop test method and also by testing the effect of each material when used as a shoe insert in 16 asymptomatic subjects. Peak vertical ground reaction force (F1, F2, F3) and temporal force factors (T1, T2, T3) were obtained with a force plate at a high-frequency sampling rate. Impact force, impact time, impact slope, and impact energy were determined. A standard weight was dropped from 3 heights on each material covering the force plate while reduction of peak force was compared. Impact force was attenuated most effectively by Insert 3 (polymeric foam rubber) and averaged 11% less than that in shoes without inserts. Impact time was increased for all 3 inserts. Impact slope and impact energy were reduced significantly in Insert 3. There was a significant difference in peak vertical force F1 for all 3 inserts, in vertical force F2 for Insert 2 (viscoelastic polymeric material), and in vertical force F3 for Insert 2. Drop-test studies showed that at all ball heights, the highest mean peak force was observed consistently in Insert 2.
Fracture of Reduced-Diameter Zirconia Dental Implants Following Repeated Insertion.
Karl, Matthias; Scherg, Stefan; Grobecker-Karl, Tanja
Achievement of high insertion torque values indicating good primary stability is a goal during dental implant placement. The objective of this study was to evaluate whether or not two-piece implants made from zirconia ceramic may be damaged as a result of torque application. A total of 10 two-piece zirconia implants were repeatedly inserted into polyurethane foam material with increasing density and decreasing osteotomy size. The insertion torque applied was measured, and implants were checked for fractures by applying the fluorescent penetrant method. Weibull probability of failure was calculated based on the recorded insertion torque values. Catastrophic failures could be seen in five of the implants from two different batches at insertion torques ranging from 46.0 to 70.5 Ncm, while the remaining implants (all belonging to one batch) survived. Weibull probability of failure seems to be low at the manufacturer-recommended maximum insertion torque of 35 Ncm. Chipping fractures at the thread tips as well as tool marks were the only otherwise observed irregularities. While high insertion torques may be desirable for immediate loading protocols, zirconia implants may fracture when manufacturer-recommended insertion torques are exceeded. Evaluating bone quality prior to implant insertion may be useful.
Critical behavior of the van der Waals bonded ferromagnet Fe 3 - x GeTe 2
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Yu; Ivanovski, V. N.; Petrovic, C.
The critical properties of the single-crystalline van der Waals bonded ferromagnet Fe 3-xGeTe 2 were investigated by bulk dc magnetization around the paramagnetic to ferromagnetic (FM) phase transition. The Fe 3-xGeTe 2 single crystals grown by self-flux method with Fe deficiency x ≈ 0.36 exhibit bulk FM ordering below T c = 152 K. The Mössbauer spectroscopy was used to provide information on defects and local atomic environment in such crystals. Critical exponents β = 0.372(4) with a critical temperature T c= 151.25(5) K and γ = 1.265(15) with T c = 151.17(12) K are obtained by the Kouvel-Fisher method,more » whereas δ = 4.50 ( 1 ) is obtained by a critical isotherm analysis at T c = 151 K. These critical exponents obey the Widom scaling relation δ = 1 + γ / β , indicating self-consistency of the obtained values. With these critical exponents the isotherm M(H) curves below and above the critical temperatures collapse into two independent universal branches, obeying the single scaling equation m = f±(h), where m and h are renormalized magnetization and field, respectively. The exponents determined in this study are close to those calculated from the results of the renormalization group approach for a heuristic model of three-dimensional Heisenberg (d = 3,n = 3) spins coupled with the attractive long-range interactions between spins that decay as J(r) ≈ r -(3+σ) with σ = 1.89.« less
Critical behavior of the van der Waals bonded ferromagnet Fe 3 - x GeTe 2
Liu, Yu; Ivanovski, V. N.; Petrovic, C.
2017-10-29
The critical properties of the single-crystalline van der Waals bonded ferromagnet Fe 3-xGeTe 2 were investigated by bulk dc magnetization around the paramagnetic to ferromagnetic (FM) phase transition. The Fe 3-xGeTe 2 single crystals grown by self-flux method with Fe deficiency x ≈ 0.36 exhibit bulk FM ordering below T c = 152 K. The Mössbauer spectroscopy was used to provide information on defects and local atomic environment in such crystals. Critical exponents β = 0.372(4) with a critical temperature T c= 151.25(5) K and γ = 1.265(15) with T c = 151.17(12) K are obtained by the Kouvel-Fisher method,more » whereas δ = 4.50 ( 1 ) is obtained by a critical isotherm analysis at T c = 151 K. These critical exponents obey the Widom scaling relation δ = 1 + γ / β , indicating self-consistency of the obtained values. With these critical exponents the isotherm M(H) curves below and above the critical temperatures collapse into two independent universal branches, obeying the single scaling equation m = f±(h), where m and h are renormalized magnetization and field, respectively. The exponents determined in this study are close to those calculated from the results of the renormalization group approach for a heuristic model of three-dimensional Heisenberg (d = 3,n = 3) spins coupled with the attractive long-range interactions between spins that decay as J(r) ≈ r -(3+σ) with σ = 1.89.« less
Preparation of high temperature gas-cooled reactor fuel element
Bradley, Ronnie A.; Sease, John D.
1976-01-01
This invention relates to a method for the preparation of high temperature gas-cooled reactor (HTGR) fuel elements wherein uncarbonized fuel rods are inserted in appropriate channels of an HTGR fuel element block and the entire block is inserted in an autoclave for in situ carbonization under high pressure. The method is particularly applicable to remote handling techniques.
Repairing Hard-to-Reach Cracks in Heat-Exchanger Tubes
NASA Technical Reports Server (NTRS)
Mills, R. C., Sr.; Duesberg, J.
1986-01-01
Inaccessible leaks repaired from accessible side of tube. Fish-Mouth insert placed in cut in leaky heat-exchanger tube. Insert welded or brazed to tube, and remaining open area of cut patched. Method developed for repairing leaks in nozzle coolant tubes of Space Shuttle main engine. Method also used on other types of tubular heat exchangers.
Perturbative Normal Form Theory for the 2D Random-Field Ising Model
NASA Astrophysics Data System (ADS)
Hayden, Lorien; Raju, Archishman; Sethna, James
Bifurcation theory is important to explain scaling in many systems. For the equilibrium random-field Ising model (RFIM) in 2D, the exponentially diverging correlation length can be derived directly from the RG flows which form a pitchfork bifurcation: dw/dl = -ɛ/2 w +w3 (Bray and Moore 1985). Our perturbative normal form theory (PNFT) predicts a term w5 to be critical in describing the behavior - it cannot be removed through an analytic change of coordinates. The new form of the correlation length produced has been observed to occur in leading order without explanation (Meinke and Middleton 2005). Performing simulations of the non-equilibrium RFIM on a Voronoi lattice uncovers a transcritical bifurcation of the form dw/dl = -ɛ/2 w +w2 + Bw3 . The RG flows determined by PNFT in this case lead directly to a form for the appropriate invariant scaling combination: s exp (- 1 / σνw) (1/w + B) C + B / σν . Using this scaling combination yields a collapse which was not possible to achieve using standard methods such as Widom scaling arguments. Further, the scaling extends over a decade in the magnitude of the disorder and explains behavior down to avalanche sizes of three, the edge of complexity. This material is based upon work supported by the National Science Foundation Graduate Research Fellowship under Grant No . DGE-1144153 and a Cornell Fellowship.
Sugawara, Taku; Higashiyama, Naoki; Kaneyama, Shuichi; Sumi, Masatoshi
2017-03-15
Prospective clinical trial of the screw insertion method for posterior C1-C2 fixation utilizing the patient-specific screw guide template technique. To evaluate the efficacy of this method for insertion of C1 lateral mass screws (LMS), C2 pedicle screws (PS), and C2 laminar screws (LS). Posterior C1LMS and C2PS fixation, also known as the Goel-Harms method, can achieve immediate rigid fixation and high fusion rate, but the screw insertion carries the risk of injury to neuronal and vascular structures. Dissection of venous plexus and C2 nerve root to confirm the insertion point of the C1LMS may also cause problems. We have developed an intraoperative screw guiding method using patient-specific laminar templates. Preoperative bone images of computed tomography (CT) were analyzed using three-dimensional (3D)/multiplanar imaging software to plan the trajectories of the screws. Plastic templates with screw guiding structures were created for each lamina using 3D design and printing technology. Three types of templates were made for precise multistep guidance, and all templates were specially designed to fit and lock on the lamina during the procedure. Surgery was performed using this patient-specific screw guide template system, and placement of the screws was postoperatively evaluated using CT. Twelve patients with C1-C2 instability were treated with a total of 48 screws (24 C1LMS, 20 C2PS, 4 C2LS). Intraoperatively, each template was found to exactly fit and lock on the lamina and screw insertion was completed successfully without dissection of the venous plexus and C2 nerve root. Postoperative CT showed no cortical violation by the screws, and mean deviation of the screws from the planned trajectories was 0.70 ± 0.42 mm. The multistep, patient-specific screw guide template system is useful for intraoperative screw navigation in posterior C1-C2 fixation. This simple and economical method can improve the accuracy of screw insertion, and reduce operation time and radiation exposure of posterior C1-C2 fixation surgery. 3.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yuan, Y; Chao, M; Sheu, R
2015-06-15
Purpose: To investigate the feasibility of using DIR to propagate the manually contoured rectum and bladder from the 1st insertion to the new CT images on subsequent insertions and evaluate the segmentation performance. Methods: Ten cervical cancer patients, who were treated by T&R brachytherapy in 3–4 insertions, were retrospectively collected. In each insertion, rectum and bladder were manually delineated on the planning CT by a physicist and verified by a radiation oncologist. Using VelocityAI (Velocity Medical Solutions, Atlanta, GA), a rigid registration was firstly employed to match the bony structures between the first insertion and each of the following insertions,more » then a multi-pass B-spine DIR was carried out to further map the sub volume that encompasses rectum and bladder. The resultant deformation fields propagated contours, and dice similarity coefficient (DSC) was used to quantitatively evaluate the agreement between the propagated contours and the manually-delineated organs. For the 3rd insertion, we also evaluated if the segmentation performance could be improved by propagating the contours from the most recent insertion, i.e., the 2nd insertion. Results: On average, the contour propagation took about 1 minute. The average and standard deviation of DSC over all insertions and patients was 0.67±0.10 (range: 0.44–0.81) for rectum, and 0.78±0.07 (range: 0.63–0.87) for bladder. For the 3rd insertion, propagating contours from the 2nd insertion could improve the segmentation performance in terms of DSC from 0.63±0.10 to 0.72±0.08 for rectum, and from 0.77±0.07 to 0.79±0.06 for bladder. A Wilcoxon signed rank test indicated that the improvement was statistically significant for rectum (p = 0.004). Conclusion: The preliminary results demonstrate that deformable image registration could efficiently and accurately propagate rectum and bladder contours between CT images in different T&R brachytherapy fractions. We are incorporating the propagated contours into our learning-based method to further segment these organs.« less
Ligand interaction scan: a general method for engineering ligand-sensitive protein alleles.
Erster, Oran; Eisenstein, Miriam; Liscovitch, Mordechai
2007-05-01
The ligand interaction scan (LIScan) method is a general procedure for engineering small molecule ligand-regulated forms of a protein that is complementary to other 'reverse' genetic and chemical-genetic methods for drug-target validation. It involves insertional mutagenesis by a chemical-genetic 'switch', comprising a genetically encoded peptide module that binds with high affinity to a small-molecule ligand. We demonstrated the method with TEM-1 beta-lactamase, using a tetracysteine hexapeptide insert and a biarsenical fluorescein ligand (FlAsH).
Quadros, Rolen M; Miura, Hiromi; Harms, Donald W; Akatsuka, Hisako; Sato, Takehito; Aida, Tomomi; Redder, Ronald; Richardson, Guy P; Inagaki, Yutaka; Sakai, Daisuke; Buckley, Shannon M; Seshacharyulu, Parthasarathy; Batra, Surinder K; Behlke, Mark A; Zeiner, Sarah A; Jacobi, Ashley M; Izu, Yayoi; Thoreson, Wallace B; Urness, Lisa D; Mansour, Suzanne L; Ohtsuka, Masato; Gurumurthy, Channabasavaiah B
2017-05-17
Conditional knockout mice and transgenic mice expressing recombinases, reporters, and inducible transcriptional activators are key for many genetic studies and comprise over 90% of mouse models created. Conditional knockout mice are generated using labor-intensive methods of homologous recombination in embryonic stem cells and are available for only ~25% of all mouse genes. Transgenic mice generated by random genomic insertion approaches pose problems of unreliable expression, and thus there is a need for targeted-insertion models. Although CRISPR-based strategies were reported to create conditional and targeted-insertion alleles via one-step delivery of targeting components directly to zygotes, these strategies are quite inefficient. Here we describe Easi-CRISPR (Efficient additions with ssDNA inserts-CRISPR), a targeting strategy in which long single-stranded DNA donors are injected with pre-assembled crRNA + tracrRNA + Cas9 ribonucleoprotein (ctRNP) complexes into mouse zygotes. We show for over a dozen loci that Easi-CRISPR generates correctly targeted conditional and insertion alleles in 8.5-100% of the resulting live offspring. Easi-CRISPR solves the major problem of animal genome engineering, namely the inefficiency of targeted DNA cassette insertion. The approach is robust, succeeding for all tested loci. It is versatile, generating both conditional and targeted insertion alleles. Finally, it is highly efficient, as treating an average of only 50 zygotes is sufficient to produce a correctly targeted allele in up to 100% of live offspring. Thus, Easi-CRISPR offers a comprehensive means of building large-scale Cre-LoxP animal resources.
METHOD FOR MAKING FUEL ELEMENTS
Kates, L.W.; Campbell, R.W.; Heartel, R.H.W.
1960-08-01
A method is given for making zirconium-clad uranium wire. A tube of zirconium is closed with a zirconium plug, after which a chilled uranium core is inserted in the tube to rest against the plug. Additional plugs and cores are inserted alternately as desired. The assembly is then sheathed with iron, hot worked to the desired size, and the iron sheath removed.
Method of modifying a volume mesh using sheet insertion
Borden, Michael J [Albuquerque, NM; Shepherd, Jason F [Albuquerque, NM
2006-08-29
A method and machine-readable medium provide a technique to modify a hexahedral finite element volume mesh using dual generation and sheet insertion. After generating a dual of a volume stack (mesh), a predetermined algorithm may be followed to modify (refine) the volume mesh of hexahedral elements. The predetermined algorithm may include the steps of locating a sheet of hexahedral mesh elements, determining a plurality of hexahedral elements within the sheet to refine, shrinking the plurality of elements, and inserting a new sheet of hexahedral elements adjacently to modify the volume mesh. Additionally, another predetermined algorithm using mesh cutting may be followed to modify a volume mesh.
NASA Astrophysics Data System (ADS)
Mercuri, F.; Caruso, G.; Orazi, N.; Zammit, U.; Cicero, C.; Colacicchi Alessandri, O.; Ferretti, M.; Paoloni, S.
2018-05-01
In this paper, a new method based on the use of infrared thermography is proposed for the characterization of repairs and inserted parts on ancient bronzes. In particular, the quality of the contact between different kind of insertions and the main body of bronze statues is investigated by analysing the heat conduction process occurring across the interface between them. The thermographic results have been used to establish the nature of these inserted elements and the way they have been coupled to the main body of the statue during and after the manufacturing process. A model for the heat conduction based on the numerical finite elements method has been applied to compare the obtained results to the theoretical predictions. Measurements have been first carried out on test samples and then in the field on the Boxer at Rest (Museo Nazionale Romano in Rome), a masterpiece of the Greek Statuary, which contains a large variety of inserted items and repairs which are typical of the manufacturing process of bronze artefacts in general.
2010-10-14
High-Resolution Functional Mapping of the Venezuelan Equine Encephalitis Virus Genome by Insertional Mutagenesis and Massively Parallel Sequencing...Venezuelan equine encephalitis virus (VEEV) genome. We initially used a capillary electrophoresis method to gain insight into the role of the VEEV...Smith JM, Schmaljohn CS (2010) High-Resolution Functional Mapping of the Venezuelan Equine Encephalitis Virus Genome by Insertional Mutagenesis and
Remanent dose rates around the collimators of the LHC beam cleaning insertions.
Brugger, M; Roesler, S
2005-01-01
The LHC will require an extremely powerful and unprecedented collimation system. As approximately 30% of the LHC beam is lost in the cleaning insertions, these will become some of the most radioactive locations around the entire LHC ring. Thus, remanent dose rates to be expected during later repair or maintenance interventions must be considered in the design phase itself. As a consequence, the beam cleaning insertions form a unique test bed for a recently developed approach to calculate remanent dose rates. A set of simulations, different in complexity, is used in order to evaluate methods for the estimation of remanent dose rates. The scope, as well as the restrictions, of the omega-factor method are shown and compared with the explicit simulation approach. The latter is then used to calculate remanent dose rates in the beam cleaning insertions. Furthermore, a detailed example for maintenance dose planning is given.
Morozumi, Takeya; Toki, Daisuke; Eguchi-Ogawa, Tomoko; Uenishi, Hirohide
2011-09-01
Large-scale cDNA-sequencing projects require an efficient strategy for mass sequencing. Here we describe a method for sequencing pooled cDNA clones using a combination of transposon insertion and Gateway technology. Our method reduces the number of shotgun clones that are unsuitable for reconstruction of cDNA sequences, and has the advantage of reducing the total costs of the sequencing project.
A novel scalable manufacturing process for the production of hydrogel-forming microneedle arrays.
Lutton, Rebecca E M; Larrañeta, Eneko; Kearney, Mary-Carmel; Boyd, Peter; Woolfson, A David; Donnelly, Ryan F
2015-10-15
A novel manufacturing process for fabricating microneedle arrays (MN) has been designed and evaluated. The prototype is able to successfully produce 14×14 MN arrays and is easily capable of scale-up, enabling the transition from laboratory to industry and subsequent commercialisation. The method requires the custom design of metal MN master templates to produce silicone MN moulds using an injection moulding process. The MN arrays produced using this novel method was compared with centrifugation, the traditional method of producing aqueous hydrogel-forming MN arrays. The results proved that there was negligible difference between either methods, with each producing MN arrays with comparable quality. Both types of MN arrays can be successfully inserted in a skin simulant. In both cases the insertion depth was approximately 60% of the needle length and the height reduction after insertion was in both cases approximately 3%. Copyright © 2015 Elsevier B.V. All rights reserved.
A novel scalable manufacturing process for the production of hydrogel-forming microneedle arrays
Lutton, Rebecca E.M.; Larrañeta, Eneko; Kearney, Mary-Carmel; Boyd, Peter; Woolfson, A.David; Donnelly, Ryan F.
2015-01-01
A novel manufacturing process for fabricating microneedle arrays (MN) has been designed and evaluated. The prototype is able to successfully produce 14 × 14 MN arrays and is easily capable of scale-up, enabling the transition from laboratory to industry and subsequent commercialisation. The method requires the custom design of metal MN master templates to produce silicone MN moulds using an injection moulding process. The MN arrays produced using this novel method was compared with centrifugation, the traditional method of producing aqueous hydrogel-forming MN arrays. The results proved that there was negligible difference between either methods, with each producing MN arrays with comparable quality. Both types of MN arrays can be successfully inserted in a skin simulant. In both cases the insertion depth was approximately 60% of the needle length and the height reduction after insertion was in both cases approximately 3%. PMID:26302858
Breaking the regioselectivity rule for acrylate insertion in the Mizoroki-Heck reaction.
Wucher, Philipp; Caporaso, Lucia; Roesle, Philipp; Ragone, Francesco; Cavallo, Luigi; Mecking, Stefan; Göttker-Schnetmann, Inigo
2011-05-31
In modern methods for the preparation of small molecules and polymers, the insertion of substrate carbon-carbon double bonds into metal-carbon bonds is a fundamental step of paramount importance. This issue is illustrated by Mizoroki-Heck coupling as the most prominent example in organic synthesis and also by catalytic insertion polymerization. For unsymmetric substrates H(2)C = CHX the regioselectivity of insertion is decisive for the nature of the product formed. Electron-deficient olefins insert selectively in a 2,1-fashion for electronic reasons. A means for controlling this regioselectivity is lacking to date. In a combined experimental and theoretical study, we now report that, by destabilizing the transition state of 2,1-insertion via steric interactions, the regioselectivity of methyl acrylate insertion into palladium-methyl and phenyl bonds can be inverted entirely to yield the opposite "regioirregular" products in stoichiometric reactions. Insights from these experiments will aid the rational design of complexes which enable a catalytic and regioirregular Mizoroki-Heck reaction of electron-deficient olefins.
Characterization of the NEXT Hollow Cathode Inserts After Long-Duration Testing
NASA Technical Reports Server (NTRS)
Mackey, J.; Shastry, R.; Soulas, G.
2017-01-01
Hollow dispenser cathode inserts are a critical element of electric propulsion systems, and should therefore be well understood during long term operation to ensure reliable system performance. This work destructively investigated cathode inserts from the NEXT long-duration test which demonstrated 51,184 hours of high-voltage operation, 918 kg of propellant throughput, and 35.5 MN-s of total impulse. The characterization methods used include scanning electron microscopy with energy dispersive spectroscopy and X-ray diffraction. Microscopy analysis has been performed on fractured surfaces, emission surfaces, and metallographically polished cross-sections of post-test inserts and unused inserts. Impregnate distribution, etch region thickness, impregnate chemical content, emission surface topography, and emission surface phase identification are the primary factors investigated.
ms2: A molecular simulation tool for thermodynamic properties
NASA Astrophysics Data System (ADS)
Deublein, Stephan; Eckl, Bernhard; Stoll, Jürgen; Lishchuk, Sergey V.; Guevara-Carrion, Gabriela; Glass, Colin W.; Merker, Thorsten; Bernreuther, Martin; Hasse, Hans; Vrabec, Jadran
2011-11-01
This work presents the molecular simulation program ms2 that is designed for the calculation of thermodynamic properties of bulk fluids in equilibrium consisting of small electro-neutral molecules. ms2 features the two main molecular simulation techniques, molecular dynamics (MD) and Monte-Carlo. It supports the calculation of vapor-liquid equilibria of pure fluids and multi-component mixtures described by rigid molecular models on the basis of the grand equilibrium method. Furthermore, it is capable of sampling various classical ensembles and yields numerous thermodynamic properties. To evaluate the chemical potential, Widom's test molecule method and gradual insertion are implemented. Transport properties are determined by equilibrium MD simulations following the Green-Kubo formalism. ms2 is designed to meet the requirements of academia and industry, particularly achieving short response times and straightforward handling. It is written in Fortran90 and optimized for a fast execution on a broad range of computer architectures, spanning from single processor PCs over PC-clusters and vector computers to high-end parallel machines. The standard Message Passing Interface (MPI) is used for parallelization and ms2 is therefore easily portable to different computing platforms. Feature tools facilitate the interaction with the code and the interpretation of input and output files. The accuracy and reliability of ms2 has been shown for a large variety of fluids in preceding work. Program summaryProgram title:ms2 Catalogue identifier: AEJF_v1_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/AEJF_v1_0.html Program obtainable from: CPC Program Library, Queen's University, Belfast, N. Ireland Licensing provisions: Special Licence supplied by the authors No. of lines in distributed program, including test data, etc.: 82 794 No. of bytes in distributed program, including test data, etc.: 793 705 Distribution format: tar.gz Programming language: Fortran90 Computer: The simulation tool ms2 is usable on a wide variety of platforms, from single processor machines over PC-clusters and vector computers to vector-parallel architectures. (Tested with Fortran compilers: gfortran, Intel, PathScale, Portland Group and Sun Studio.) Operating system: Unix/Linux, Windows Has the code been vectorized or parallelized?: Yes. Message Passing Interface (MPI) protocol Scalability. Excellent scalability up to 16 processors for molecular dynamics and >512 processors for Monte-Carlo simulations. RAM:ms2 runs on single processors with 512 MB RAM. The memory demand rises with increasing number of processors used per node and increasing number of molecules. Classification: 7.7, 7.9, 12 External routines: Message Passing Interface (MPI) Nature of problem: Calculation of application oriented thermodynamic properties for rigid electro-neutral molecules: vapor-liquid equilibria, thermal and caloric data as well as transport properties of pure fluids and multi-component mixtures. Solution method: Molecular dynamics, Monte-Carlo, various classical ensembles, grand equilibrium method, Green-Kubo formalism. Restrictions: No. The system size is user-defined. Typical problems addressed by ms2 can be solved by simulating systems containing typically 2000 molecules or less. Unusual features: Feature tools are available for creating input files, analyzing simulation results and visualizing molecular trajectories. Additional comments: Sample makefiles for multiple operation platforms are provided. Documentation is provided with the installation package and is available at http://www.ms-2.de. Running time: The running time of ms2 depends on the problem set, the system size and the number of processes used in the simulation. Running four processes on a "Nehalem" processor, simulations calculating VLE data take between two and twelve hours, calculating transport properties between six and 24 hours.
Ning, Shaoli; Zhao, Lihua; Xu, Lingjun; Huang, Yu; Pang, Yong; Huang, Dingjian
2016-01-01
To compare the effects between slow twisting needle insertion and tubing needle insertion. With cross-over design, 100 healthy young subjects (half male and half female) aged from 19 to 23 years were randomly divided into two groups by random digital table, 50 cases in each one. At the first stage, subjects in the group A were treated with slow twisting needle insertion while, subjects in,the group B were treated with tubing needle insertion. One week later, the procedure of second stage was performed alternately. The needle was inserted into Neiguan (PC 6) with two methods by one acupuncturist. The needle was retained for 5 min before removal. Five min before needle insertion as well as needle withdrawal and 30 min after needle withdrawal, ZXG-E automatic cardiovascular diagnostic apparatus was used to test cardiovascular function. At the tim of needle withdrawal, slow twisting needle insertion could improve effect work of kinetics (EWK), effective blood volume (BV) and reduce elastic expansion coefficient of blood vessel (FEK) and left ventricular spray blood impedance (VER), which was significantly different from tubing needle insertion (all P < 0.05). Thirty min after needle withdrawal, the differences of the indices of cardiovascular function between the two groups were not significant (all P > 0.05). The slow twisting needle insertion is significantly superior to tubing needle insertion on lowering vascular tension and VER, improving EWK and BV.
Rossa, Carlos; Lehmann, Thomas; Sloboda, Ronald; Usmani, Nawaid; Tavakoli, Mahdi
2017-08-01
Global modelling has traditionally been the approach taken to estimate needle deflection in soft tissue. In this paper, we propose a new method based on local data-driven modelling of needle deflection. External measurement of needle-tissue interactions is collected from several insertions in ex vivo tissue to form a cloud of data. Inputs to the system are the needle insertion depth, axial rotations, and the forces and torques measured at the needle base by a force sensor. When a new insertion is performed, the just-in-time learning method estimates the model outputs given the current inputs to the needle-tissue system and the historical database. The query is compared to every observation in the database and is given weights according to some similarity criteria. Only a subset of historical data that is most relevant to the query is selected and a local linear model is fit to the selected points to estimate the query output. The model outputs the 3D deflection of the needle tip and the needle insertion force. The proposed approach is validated in ex vivo multilayered biological tissue in different needle insertion scenarios. Experimental results in five different case studies indicate an accuracy in predicting needle deflection of 0.81 and 1.24 mm in the horizontal and vertical lanes, respectively, and an accuracy of 0.5 N in predicting the needle insertion force over 216 needle insertions.
Elazar, Assaf; Weinstein, Jonathan; Biran, Ido; Fridman, Yearit; Bibi, Eitan; Fleishman, Sarel Jacob
2016-01-29
Insertion of helix-forming segments into the membrane and their association determines the structure, function, and expression levels of all plasma membrane proteins. However, systematic and reliable quantification of membrane-protein energetics has been challenging. We developed a deep mutational scanning method to monitor the effects of hundreds of point mutations on helix insertion and self-association within the bacterial inner membrane. The assay quantifies insertion energetics for all natural amino acids at 27 positions across the membrane, revealing that the hydrophobicity of biological membranes is significantly higher than appreciated. We further quantitate the contributions to membrane-protein insertion from positively charged residues at the cytoplasm-membrane interface and reveal large and unanticipated differences among these residues. Finally, we derive comprehensive mutational landscapes in the membrane domains of Glycophorin A and the ErbB2 oncogene, and find that insertion and self-association are strongly coupled in receptor homodimers.
Method of creating a controlled interior surface configuration of passages within a substrate
Dembowski, Peter V.; Schilke, Peter W.
1983-01-01
A method of creating a controlled interior surface configuration of passages within a substrate, particularly cooling passages of nozzles or buckets of a gas turbine, involves the hot isostatic pressing of a leachable passage insert whose surface carries the female image of the desired interior surface configuration inside the substrate followed by leaching of the insert from the substrate.
Casanova, Fernando; Carney, Paul R; Sarntinoranont, Malisa
2014-11-30
Convection enhanced delivery (CED) infuses drugs directly into brain tissue. Needle insertion is required and results in tissue damage which can promote flowback along the needle track and improper targeting. The goal of this study was to evaluate friction stress (calculated from needle insertion force) as a measure of tissue contact and damage during needle insertion for varying insertion speeds. Forces and surface dimpling during needle insertion were measured in rat brain in vivo. Needle retraction forces were used to calculate friction stresses. These measures were compared to track damage from a previous study. Differences between brain tissues and soft hydrogels were evaluated for varying insertion speeds: 0.2, 2, and 10mm/s. In brain tissue, average insertion force and surface dimpling increased with increasing insertion speed. Average friction stress along the needle-tissue interface decreased with insertion speed (from 0.58 ± 0.27 to 0.16 ± 0.08 kPa). Friction stress varied between brain regions: cortex (0.227 ± 0.27 kPa), external capsule (0.222 ± 0.19 kPa), and CPu (0.383 ± 0.30 kPa). Hydrogels exhibited opposite trends for dimpling and friction stress with insertion speed. Previously, increasing needle damage with insertion speed has been measured with histological methods. Friction stress appears to decrease with increasing tissue damage and decreasing tissue contact, providing the potential for in vivo and real time evaluation along the needle track. Force derived friction stress decreased with increasing insertion speed and was smaller within white matter regions. Hydrogels exhibited opposite trends to brain tissue. Copyright © 2014 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Woodley-Cook, Joel, E-mail: jwoodleycook@gmail.com; Tarulli, Emidio; Tan, Kong T.
PurposePlacement of peritoneal ports has become a favorable technique for direct chemotherapy infusion in treating peritoneal metastases from ovarian cancer. We aim to outline an approach to the percutaneous insertion of peritoneal ports and to characterize success and complication rates compared to surgically inserted ports.Materials and MethodsRetrospective analysis was collected from 87 patients who had peritoneal port insertion (28 inserted surgically and 59 percutaneously) for treatment of peritoneal metastases from ovarian cancer from July 2004 to July 2014. Complications were classified according to the SIR Clinical Practice Guidelines as major or minor.ResultsTechnical success rates for surgically and percutaneously inserted portsmore » were 100 and 96.7 %, respectively (p = 0.44), with the two percutaneous failures successful at a later date. There were no major complications in either group. Minor complication rates for surgically versus percutaneously inserted ports were 46.4 versus 22.0 %, respectively (p = 0.02). The infection rate for surgically inserted versus percutaneously inserted ports was 14.3 and 0 %, respectively (p = 0.002). The relative risk of developing a complication from percutaneous peritoneal port insertion without ascites was 3.4 (p = 0.04). For percutaneously inserted ports, the mean in-room procedure time was 81 ± 1.3 min and mean fluoroscopy time was 5.0 ± 4.5 min.ConclusionPercutaneously inserted peritoneal ports are a safe alternative to surgically inserted ports, demonstrating similar technical success and lower complication rates.« less
Choe, Seungho; Hecht, Karen A.; Grabe, Michael
2008-01-01
Continuum electrostatic approaches have been extremely successful at describing the charged nature of soluble proteins and how they interact with binding partners. However, it is unclear whether continuum methods can be used to quantitatively understand the energetics of membrane protein insertion and stability. Recent translation experiments suggest that the energy required to insert charged peptides into membranes is much smaller than predicted by present continuum theories. Atomistic simulations have pointed to bilayer inhomogeneity and membrane deformation around buried charged groups as two critical features that are neglected in simpler models. Here, we develop a fully continuum method that circumvents both of these shortcomings by using elasticity theory to determine the shape of the deformed membrane and then subsequently uses this shape to carry out continuum electrostatics calculations. Our method does an excellent job of quantitatively matching results from detailed molecular dynamics simulations at a tiny fraction of the computational cost. We expect that this method will be ideal for studying large membrane protein complexes. PMID:18474636
Apparatus and method of inserting a microelectrode in body tissue or the like using vibration means
NASA Technical Reports Server (NTRS)
Feldstein, C.; Crawford, D. W.; Kanabus, E. W. (Inventor)
1979-01-01
An arrangement for and method of inserting a glass microelectrode having a tip in the micron range into body tissue is presented. The arrangement includes a microelectrode. The top of the microelectrode is attached to the diaphragm center of a first speaker. The microelectrode tip is brought into contact with the tissue by controlling a micromanipulator. Thereafter, an audio signal is applied to the speaker to cause the microelectrode to vibrate and thereby pierce the tissue surface without breaking the microelectrode tip. Thereafter, the tip is inserted into the tissue to the desired depth by operating the micromanipulator with the microelectrode in a vibratory or non-vibratory state.
Steinberg, Meyer; Manowitz, Bernard; Waide, Charles H.
1976-01-06
Method and apparatus for producing rockbolts in the roof of a subterranean cavity in which two components of an ambient temperature curable resin system are premixed and then inserted into a bore hole. The mixture is permitted to polymerize in situ and then the hardened material is cut off at the entrance to the hole leaving a hardened portion for insertion into the next hole as a precursor. In a preferred embodiment a flexible glass roving is employed to reinforce the material in the hole and a metal tube inserted to support the roving while it is fed into the hole and also to provide venting. The roving and tube is then cut off and left in the hole.
Apparatus and method for magnetically processing a specimen
Ludtka, Gerard M; Ludtka, Gail M; Wilgen, John B; Kisner, Roger A; Jaramillo, Roger A
2013-09-03
An apparatus for magnetically processing a specimen that couples high field strength magnetic fields with the magnetocaloric effect includes a high field strength magnet capable of generating a magnetic field of at least 1 Tesla and a magnetocaloric insert disposed within a bore of the high field strength magnet. A method for magnetically processing a specimen includes positioning a specimen adjacent to a magnetocaloric insert within a bore of a magnet and applying a high field strength magnetic field of at least 1 Tesla to the specimen and to the magnetocaloric insert. The temperature of the specimen changes during the application of the high field strength magnetic field due to the magnetocaloric effect.
Development and comparison of projection and image space 3D nodule insertion techniques
NASA Astrophysics Data System (ADS)
Robins, Marthony; Solomon, Justin; Sahbaee, Pooyan; Samei, Ehsan
2016-04-01
This study aimed to develop and compare two methods of inserting computerized virtual lesions into CT datasets. 24 physical (synthetic) nodules of three sizes and four morphologies were inserted into an anthropomorphic chest phantom (LUNGMAN, KYOTO KAGAKU). The phantom was scanned (Somatom Definition Flash, Siemens Healthcare) with and without nodules present, and images were reconstructed with filtered back projection and iterative reconstruction (SAFIRE) at 0.6 mm slice thickness using a standard thoracic CT protocol at multiple dose settings. Virtual 3D CAD models based on the physical nodules were virtually inserted (accounting for the system MTF) into the nodule-free CT data using two techniques. These techniques include projection-based and image-based insertion. Nodule volumes were estimated using a commercial segmentation tool (iNtuition, TeraRecon, Inc.). Differences were tested using paired t-tests and R2 goodness of fit between the virtually and physically inserted nodules. Both insertion techniques resulted in nodule volumes very similar to the real nodules (<3% difference) and in most cases the differences were not statistically significant. Also, R2 values were all <0.97 for both insertion techniques. These data imply that these techniques can confidently be used as a means of inserting virtual nodules in CT datasets. These techniques can be instrumental in building hybrid CT datasets composed of patient images with virtually inserted nodules.
Bending stiffness, torsional stability, and insertion force of cementless femoral stems.
Incavo, S J; Johnson, C C; Churchill, D L; Beynnon, B D
2001-04-01
In cementless total hip arthroplasty, increased femoral stem flexibility and decreased fracture propensity are desirable characteristics. The slotting and tapering of the stem have been introduced to achieve this. These features should not, however, be allowed to interfere with the ability of the distal stem to provide initial mechanical stability, especially under rotation. This study was done to investigate the ability of slotted and tapered stem designs to reduce stiffness and insertion force while still maintaining adequate torsional strength. The torsional strength, maximum insertion force, and insertional work of straight, slotted, and taper stems were measured by inserting each type into rigid polyurethane foam and torque testing to failure. Bending stiffness of each stem design was calculated using numerical methods. When compared to a straight stem, a unislot stem has similar torsional strength, maximum insertional force, and work of insertion. The bending stiffness is decreased by 19% to 82% depending on the bending direction. A trislot design decreased torque strength by 29%, maximal insertion force by 36%, and work by 11%. Bending stiffness was decreased by 74% and was not dependent on bending direction. A 0.5-mm taper decreased torque strength by 11% and insertional work by 14%. No difference was seen in maximum insertional force. We conclude that the design features studied (slots and taper) are effective in decreasing stem stiffness and reducing fracture propensity.
Histological Analysis of the Tibial Anterior Cruciate Ligament Insertion
Siebold, Rainer; Oka, Shinya; Traut, Ulrike; Schuhmacher, Peter; Kirsch, Joachim
2017-01-01
Objective: To describe the morphology of the tibial ACL insertion by histological assessment in the sagittal plane. Methods: For histology the native (undissected) tibial ACL insertion of 6 fresh-frozen cadaveric knees was cut into 4 sagittal sections parallel to the long axis of the medial tibial spine. The slices were stained with hematoxylin and eosin, Safranin O and Russell-Movat pentachrome. All slices were digitalized and analyzed at a magnification of ×20. Results: From medial to lateral the anterior-posterior lengths of the ACL insertion were an average of 10.2, 9.3, 7.6 and 5.8 mm. The anterior margin of the tibial ACL insertion raised from an anterior ridge. The most medial ACL fibers rose along with a peak of the anterior part of the medial tibial spine in which the direct insertion was adjacent to the articular cartilage. Parts of the bony insertions of the anterior and posterior horns of the lateral meniscus were in close contact to the lateral ACL insertion. A small fat pad was located just posterior to the tibial ACL insertion. There were no central or posterolateral inserting ACL fibers in the area intercondylaris anterior. Conclusion: The functional intraligamentous midsubstance ACL fibers arose from the most posterior part of its bony tibial insertion in a flat and “C-shape” way. The anterior border of this functional ACL started from a bony ‘anterior ridge’ and the medial border was along with a peak of the medial tibial spine.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Wenguang, E-mail: zhwg@sjtu.edu.cn; Ma, Yakun; Li, Zhengwei
Purpose: The application of neural probes in clinic has been challenged by probes’ short lifetime when implanted into brain tissue. The primary goal is to develop an evaluation system for testing brain tissue injury induced by neural probe’s insertion using microscope based digital image correlation method. Methods: A brain tissue phantom made of silicone rubber with speckle pattern on its surface was fabricated. To obtain the optimal speckle pattern, mean intensity gradient parameter was used for quality assessment. The designed testing system consists of three modules: (a) load module for simulating neural electrode implantation process; (b) data acquisition module tomore » capture micrographs of speckle pattern and to obtain reactive forces during the insertion of the probe; (c) postprocessing module for extracting tissue deformation information from the captured speckle patterns. On the basis of the evaluation system, the effects of probe wedge angle, insertion speed, and probe streamline on insertion induced tissue injury were investigated. Results: The optimal quality speckle pattern can be attained by the following fabrication parameters: spin coating rate—1000 r/min, silicone rubber component A: silicone rubber component B: softener: graphite = 5 ml: 5 ml: 2 ml: 0.6 g. The probe wedge angle has a significant effect on tissue injury. Compared to wedge angle 40° and 20°, maximum principal strain of 60° wedge angle was increased by 40.3% and 87.5%, respectively; compared with a relatively higher speed (500 μm/s), the maximum principle strain within the tissue induced by slow insertion speed (100 μm/s) was increased by 14.3%; insertion force required by probe with convex streamline was smaller than the force of traditional probe. Based on the experimental results, a novel neural probe that has a rounded tip covered by a biodegradable silk protein coating with convex streamline was proposed, which has both lower insertion and micromotion induced tissue injury. Conclusions: The established evaluation system has provided a simulation environment for testing brain tissue injury produced by various insertion conditions. At the same time, it eliminates the adverse effect of biological factors on tissue deformation during the experiment, improving the repeatability of measurement results. As a result, the evaluation system will provide support on novel neural probe design that can reduce the acute tissue injury during the implantation of the probe.« less
Yeo, Caitlin T; Ungi, Tamas; U-Thainual, Paweena; Lasso, Andras; McGraw, Robert C; Fichtinger, Gabor
2011-07-01
The purpose of this study was to determine if augmented reality image overlay and laser guidance systems can assist medical trainees in learning the correct placement of a needle for percutaneous facet joint injection. The Perk Station training suite was used to conduct and record the needle insertion procedures. A total of 40 volunteers were randomized into two groups of 20. 1) The Overlay group received a training session that consisted of four insertions with image and laser guidance, followed by two insertions with laser overlay only. 2) The Control group received a training session of six classical freehand insertions. Both groups then conducted two freehand insertions. The movement of the needle was tracked during the series of insertions. The final insertion procedure was assessed to determine if there was a benefit to the overlay method compared to the freehand insertions. The Overlay group had a better success rate (83.3% versus 68.4%, p=0.002), and potential for less tissue damage as measured by the amount of needle movement inside the phantom (3077.6 mm(2) versus 5607.9 mm(2) , p =0.01). These results suggest that an augmented reality overlay guidance system can assist medical trainees in acquiring technical competence in a percutaneous needle insertion procedure. © 2011 IEEE
Measurement of impulse peak insertion loss for four hearing protection devices in field conditions
Murphy, William J.; Flamme, Gregory A.; Meinke, Deanna K.; Sondergaard, Jacob; Finan, Donald S.; Lankford, James E.; Khan, Amir; Vernon, Julia; Stewart, Michael
2015-01-01
Objective In 2009, the U.S. Environmental Protection Agency (EPA) proposed an impulse noise reduction rating (NRR) for hearing protection devices based upon the impulse peak insertion loss (IPIL) methods in the ANSI S12.42-2010 standard. This study tests the ANSI S12.42 methods with a range of hearing protection devices measured in field conditions. Design The method utilizes an acoustic test fixture and three ranges for impulse levels: 130–134, 148–152, and 166–170 dB peak SPL. For this study, four different models of hearing protectors were tested: Bilsom 707 Impact II electronic earmuff, E·A·R Pod Express, E·A·R Combat Arms version 4, and the Etymotic Research, Inc. Electronic BlastPLG™ EB1. Study sample Five samples of each protector were fitted on the fixture or inserted in the fixture's ear canal five times for each impulse level. Impulses were generated by a 0.223 caliber rifle. Results The average IPILs increased with peak pressure and ranged between 20 and 38 dB. For some protectors, significant differences were observed across protector examples of the same model, and across insertions. Conclusions The EPA's proposed methods provide consistent and reproducible results. The proposed impulse NRR rating should utilize the minimum and maximum protection percentiles as determined by the ANSI S12.42-2010 methods. PMID:22176308
Instability of the insertional mutation in CftrTgH(neoim)Hgu cystic fibrosis mouse model
Charizopoulou, Nikoletta; Jansen, Silke; Dorsch, Martina; Stanke, Frauke; Dorin, Julia R; Hedrich, Hans-Jürgen; Tümmler, Burkhard
2004-01-01
Background A major boost to the cystic fibrosis disease research was given by the generation of various mouse models using gene targeting in embryonal stem cells. Moreover, the introduction of the same mutation on different inbred strains generating congenic strains facilitated the search for modifier genes. From the original CftrTgH(neoim)Hgu CF mouse model we have generated using strict brother × sister mating two inbred CftrTgH(neoim)Hgu mouse lines (CF/1 and CF/3). Thereafter, the insertional mutation was introgressed from CF/3 into three inbred backgrounds (C57BL/6, BALB/c, DBA/2J) generating congenic animals. In every backcross cycle germline transmission of the insertional mutation was monitored by direct probing the insertion via Southern RFLP. In order to bypass this time consuming procedure we devised an alternative PCR based protocol whereby mouse strains are differentiated at the Cftr locus by Cftr intragenic microsatellite genotypes that are tightly linked to the disrupted locus. Results Using this method we were able to identify animals carrying the insertional mutation based upon the differential haplotypic backgrounds of the three inbred strains and the mutant CftrTgH(neoim)Hgu at the Cftr locus. Moreover, this method facilitated the identification of the precise vector excision from the disrupted Cftr locus in two out of 57 typed animals. This reversion to wild type status took place without any loss of sequence revealing the instability of insertional mutations during the production of congenic animals. Conclusions We present intragenic microsatellite markers as a tool for fast and efficient identification of the introgressed locus of interest in the recipient strain during congenic animal breeding. Moreover, the same genotyping method allowed the identification of a vector excision event, posing questions on the stability of insertional mutations in mice. PMID:15102331
Park, Doori; Park, Su-Hyun; Ban, Yong Wook; Kim, Youn Shic; Park, Kyoung-Cheul; Kim, Nam-Soo; Kim, Ju-Kon; Choi, Ik-Young
2017-08-15
Genetically modified crops (GM crops) have been developed to improve the agricultural traits of modern crop cultivars. Safety assessments of GM crops are of paramount importance in research at developmental stages and before releasing transgenic plants into the marketplace. Sequencing technology is developing rapidly, with higher output and labor efficiencies, and will eventually replace existing methods for the molecular characterization of genetically modified organisms. To detect the transgenic insertion locations in the three GM rice gnomes, Illumina sequencing reads are mapped and classified to the rice genome and plasmid sequence. The both mapped reads are classified to characterize the junction site between plant and transgene sequence by sequence alignment. Herein, we present a next generation sequencing (NGS)-based molecular characterization method, using transgenic rice plants SNU-Bt9-5, SNU-Bt9-30, and SNU-Bt9-109. Specifically, using bioinformatics tools, we detected the precise insertion locations and copy numbers of transfer DNA, genetic rearrangements, and the absence of backbone sequences, which were equivalent to results obtained from Southern blot analyses. NGS methods have been suggested as an effective means of characterizing and detecting transgenic insertion locations in genomes. Our results demonstrate the use of a combination of NGS technology and bioinformatics approaches that offers cost- and time-effective methods for assessing the safety of transgenic plants.
Younger, Andrew K D; Su, Peter Y; Shepard, Andrea J; Udani, Shreya V; Cybulski, Thaddeus R; Tyo, Keith E J; Leonard, Joshua N
2018-02-01
Naturally evolved metabolite-responsive biosensors enable applications in metabolic engineering, ranging from screening large genetic libraries to dynamically regulating biosynthetic pathways. However, there are many metabolites for which a natural biosensor does not exist. To address this need, we developed a general method for converting metabolite-binding proteins into metabolite-responsive transcription factors-Biosensor Engineering by Random Domain Insertion (BERDI). This approach takes advantage of an in vitro transposon insertion reaction to generate all possible insertions of a DNA-binding domain into a metabolite-binding protein, followed by fluorescence activated cell sorting to isolate functional biosensors. To develop and evaluate the BERDI method, we generated a library of candidate biosensors in which a zinc finger DNA-binding domain was inserted into maltose binding protein, which served as a model well-studied metabolite-binding protein. Library diversity was characterized by several methods, a selection scheme was deployed, and ultimately several distinct and functional maltose-responsive transcriptional biosensors were identified. We hypothesize that the BERDI method comprises a generalizable strategy that may ultimately be applied to convert a wide range of metabolite-binding proteins into novel biosensors for applications in metabolic engineering and synthetic biology. © The Author(s) 2018. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
Kesler, Kyle; Dillon, Neal P; Fichera, Loris; Labadie, Robert F
2017-09-01
Objectives Document human motions associated with cochlear implant electrode insertion at different speeds and determine the lower limit of continuous insertion speed by a human. Study Design Observational. Setting Academic medical center. Subjects and Methods Cochlear implant forceps were coupled to a frame containing reflective fiducials, which enabled optical tracking of the forceps' tip position in real time. Otolaryngologists (n = 14) performed mock electrode insertions at different speeds based on recommendations from the literature: "fast" (96 mm/min), "stable" (as slow as possible without stopping), and "slow" (15 mm/min). For each insertion, the following metrics were calculated from the tracked position data: percentage of time at prescribed speed, percentage of time the surgeon stopped moving forward, and number of direction reversals (ie, going from forward to backward motion). Results Fast insertion trials resulted in better adherence to the prescribed speed (45.4% of the overall time), no motion interruptions, and no reversals, as compared with slow insertions (18.6% of time at prescribed speed, 15.7% stopped time, and an average of 18.6 reversals per trial). These differences were statistically significant for all metrics ( P < .01). The metrics for the fast and stable insertions were comparable; however, stable insertions were performed 44% slower on average. The mean stable insertion speed was 52 ± 19.3 mm/min. Conclusion Results indicate that continuous insertion of a cochlear implant electrode at 15 mm/min is not feasible for human operators. The lower limit of continuous forward insertion is 52 mm/min on average. Guidelines on manual insertion kinematics should consider this practical limit of human motion.
In-plane ultrasonic needle tracking using a fiber-optic hydrophone
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xia, Wenfeng, E-mail: wenfeng.xia@ucl.ac.uk; Desjardins, Adrien E.; Mari, Jean Martial
Purpose: Accurate and efficient guidance of needles to procedural targets is critically important during percutaneous interventional procedures. Ultrasound imaging is widely used for real-time image guidance in a variety of clinical contexts, but with this modality, uncertainties about the location of the needle tip within the image plane lead to significant complications. Whilst several methods have been proposed to improve the visibility of the needle, achieving accuracy and compatibility with current clinical practice is an ongoing challenge. In this paper, the authors present a method for directly visualizing the needle tip using an integrated fiber-optic ultrasound receiver in conjunction withmore » the imaging probe used to acquire B-mode ultrasound images. Methods: Needle visualization and ultrasound imaging were performed with a clinical ultrasound imaging system. A miniature fiber-optic ultrasound hydrophone was integrated into a 20 gauge injection needle tip to receive transmissions from individual transducer elements of the ultrasound imaging probe. The received signals were reconstructed to create an image of the needle tip. Ultrasound B-mode imaging was interleaved with needle tip imaging. A first set of measurements was acquired in water and tissue ex vivo with a wide range of insertion angles (15°–68°) to study the accuracy and sensitivity of the tracking method. A second set was acquired in an in vivo swine model, with needle insertions to the brachial plexus. A third set was acquired in an in vivo ovine model for fetal interventions, with insertions to different locations within the uterine cavity. Two linear ultrasound imaging probes were used: a 14–5 MHz probe for the first and second sets, and a 9–4 MHz probe for the third. Results: During insertions in tissue ex vivo and in vivo, the imaged needle tip had submillimeter axial and lateral dimensions. The signal-to-noise (SNR) of the needle tip was found to depend on the insertion angle. With the needle tip in water, the SNR of the needle tip varied with insertion angle, attaining values of 284 at 27° and 501 at 68°. In swine tissue ex vivo, the SNR decreased from 80 at 15° to 16 at 61°. In swine tissue in vivo, the SNR varied with depth, from 200 at 17.5 mm to 48 at 26 mm, with a constant insertion angle of 40°. In ovine tissue in vivo, within the uterine cavity, the SNR varied from 46.4 at 25 mm depth to 18.4 at 32 mm depth, with insertion angles in the range of 26°–65°. Conclusions: A fiber-optic ultrasound receiver integrated into the needle cannula in combination with single-element transmissions from the imaging probe allows for direct visualization of the needle tip within the ultrasound imaging plane. Visualization of the needle tip was achieved at depths and insertion angles that are encountered during nerve blocks and fetal interventions. The method presented in this paper has strong potential to improve the safety and efficiency of ultrasound-guided needle insertions.« less
Jia, Xianbo; Lin, Xinjian; Chen, Jichen
2017-11-02
Current genome walking methods are very time consuming, and many produce non-specific amplification products. To amplify the flanking sequences that are adjacent to Tn5 transposon insertion sites in Serratia marcescens FZSF02, we developed a genome walking method based on TAIL-PCR. This PCR method added a 20-cycle linear amplification step before the exponential amplification step to increase the concentration of the target sequences. Products of the linear amplification and the exponential amplification were diluted 100-fold to decrease the concentration of the templates that cause non-specific amplification. Fast DNA polymerase with a high extension speed was used in this method, and an amplification program was used to rapidly amplify long specific sequences. With this linear and exponential TAIL-PCR (LETAIL-PCR), we successfully obtained products larger than 2 kb from Tn5 transposon insertion mutant strains within 3 h. This method can be widely used in genome walking studies to amplify unknown sequences that are adjacent to known sequences.
2016-02-01
certification process. INTRODUCTION The ultrasonic inspection of aerospace composites has been demonstrated to be one of the most effective methods to...normal part conditions. Anomalous indications studied in this program include inserted materials, porosity, ply ‘laps and gaps’, and wrinkles . Inserted...partially scanned inserts at the radii. Wrinkles , laps and gaps have also been included in the truth table, but detection rates for these flaws are
Human Alu insertion polymorphisms in North African populations.
Cherni, Loth; Frigi, Sabeh; Ennafaa, Hajer; Mtiraoui, Nabil; Mahjoub, Touhami; Benammar-Elgaaied, Amel
2011-10-01
Several features make Alu insertions a powerful tool used in population genetic studies: the polymorphic nature of many Alu insertions, the stability of an Alu insertion event and, furthermore, the ancestral state of an Alu insertion is known to be the absence of the Alu element at a particular locus and the presence of an Alu insertion at the site that forward mutational change. This study analyses seven Alu insertion polymorphisms in a sample of 297 individuals from the autochthonous population of Tunisia (Thala, Smar, Zarzis, and Bou Salem) and Libya with the aim of studying their genetic structure with respect to the populations of North Africa, Western, Eastern and Central Europe. The comparative analyses carried out using the MDS and AMOVA methods reveal the existence of spatial heterogeneity, and identify four population groups. Study populations (Libya, Smar, Zarzis, and Bou Salem) are closest to North African populations whereas Thala is isolated and is closest to Western European populations. In conclusion, Results of the present study support the important role that migratory movements have played in the North African gene pool, at least since the Neolithic period.
Mitra, V; Hu, M; Majumdar, D; Krishnan, V; Chaudhury, B; Hancock, J; Dwarakanath, D
2017-03-01
Self-expandable metal stents are often used to treat obstructive large bowel cancers. This study assessed the safety and efficacy of colonic stent insertion carried out in a district general hospital. Methods A retrospective review was carried out between 1 January 2007 and 28 February 2014 to identify patients who underwent stent insertion for malignant colorectal obstruction. Results Seventy-five patients (median age 75.2 years, 70.6% male) with primary colorectal cancer underwent stent insertion - 53 underwent semi-elective self-expanded metal stent insertion (for subacute bowel obstruction) and 22 had emergency stent inserted (for acute bowel obstruction). The majority (88%) had self-expanded metal stents inserted for palliation. Technical and clinical success rates were 98.7% and 91.2%, respectively. One patient had stent-related perforation; there was no procedure-related mortality. Conclusion This study shows that self-expanded metal stent insertion in malignant colorectal obstruction is safe and effective and can be successfully delivered in a district general hospital with high technical and clinical success rates.
Implementation and Validation of an Impedance Eduction Technique
NASA Technical Reports Server (NTRS)
Watson, Willie R.; Jones, Michael G.; Gerhold, Carl H.
2011-01-01
Implementation of a pressure gradient method of impedance eduction in two NASA Langley flow ducts is described. The Grazing Flow Impedance Tube only supports plane-wave sources, while the Curved Duct Test Rig supports sources that contain higher-order modes. Multiple exercises are used to validate this new impedance eduction method. First, synthesized data for a hard wall insert and a conventional liner mounted in the Grazing Flow Impedance Tube are used as input to the two impedance eduction methods, the pressure gradient method and a previously validated wall pressure method. Comparisons between the two results are excellent. Next, data measured in the Grazing Flow Impedance Tube are used as input to both methods. Results from the two methods compare quite favorably for sufficiently low Mach numbers but this comparison degrades at Mach 0.5, especially when the hard wall insert is used. Finally, data measured with a hard wall insert mounted in the Curved Duct Test Rig are used as input to the pressure gradient method. Significant deviation from the known solution is observed, which is believed to be largely due to 3-D effects in this flow duct. Potential solutions to this issue are currently being explored.
High-precision simulation of the height distribution for the KPZ equation
NASA Astrophysics Data System (ADS)
Hartmann, Alexander K.; Le Doussal, Pierre; Majumdar, Satya N.; Rosso, Alberto; Schehr, Gregory
2018-03-01
The one-point distribution of the height for the continuum Kardar-Parisi-Zhang (KPZ) equation is determined numerically using the mapping to the directed polymer in a random potential at high temperature. Using an importance sampling approach, the distribution is obtained over a large range of values, down to a probability density as small as 10-1000 in the tails. Both short and long times are investigated and compared with recent analytical predictions for the large-deviation forms of the probability of rare fluctuations. At short times the agreement with the analytical expression is spectacular. We observe that the far left and right tails, with exponents 5/2 and 3/2, respectively, are preserved also in the region of long times. We present some evidence for the predicted non-trivial crossover in the left tail from the 5/2 tail exponent to the cubic tail of the Tracy-Widom distribution, although the details of the full scaling form remain beyond reach.
Phase transition in the parametric natural visibility graph.
Snarskii, A A; Bezsudnov, I V
2016-10-01
We investigate time series by mapping them to the complex networks using a parametric natural visibility graph (PNVG) algorithm that generates graphs depending on arbitrary continuous parameter-the angle of view. We study the behavior of the relative number of clusters in PNVG near the critical value of the angle of view. Artificial and experimental time series of different nature are used for numerical PNVG investigations to find critical exponents above and below the critical point as well as the exponent in the finite size scaling regime. Altogether, they allow us to find the critical exponent of the correlation length for PNVG. The set of calculated critical exponents satisfies the basic Widom relation. The PNVG is found to demonstrate scaling behavior. Our results reveal the similarity between the behavior of the relative number of clusters in PNVG and the order parameter in the second-order phase transitions theory. We show that the PNVG is another example of a system (in addition to magnetic, percolation, superconductivity, etc.) with observed second-order phase transition.
Log-Gamma Polymer Free Energy Fluctuations via a Fredholm Determinant Identity
NASA Astrophysics Data System (ADS)
Borodin, Alexei; Corwin, Ivan; Remenik, Daniel
2013-11-01
We prove that under n 1/3 scaling, the limiting distribution as n → ∞ of the free energy of Seppäläinen’s log-Gamma discrete directed polymer is GUE Tracy-Widom. The main technical innovation we provide is a general identity between a class of n-fold contour integrals and a class of Fredholm determinants. Applying this identity to the integral formula proved in Corwin et al. (Tropical combinatorics and Whittaker functions. http://arxiv.org/abs/1110.3489v3 [math.PR], 2012) for the Laplace transform of the log-Gamma polymer partition function, we arrive at a Fredholm determinant which lends itself to asymptotic analysis (and thus yields the free energy limit theorem). The Fredholm determinant was anticipated in Borodin and Corwin (Macdonald processes. http://arxiv.org/abs/1111.4408v3 [math.PR], 2012) via the formalism of Macdonald processes yet its rigorous proof was so far lacking because of the nontriviality of certain decay estimates required by that approach.
MINS2: revisiting the molecular code for transmembrane-helix recognition by the Sec61 translocon.
Park, Yungki; Helms, Volkhard
2008-08-15
To be fully functional, membrane proteins should not only fold, but also get inserted into the membrane, which is mediated by the Sec61 translocon. Recent experimental studies have attempted to elucidate how the Sec61 translocon accomplishes this delicate task by measuring the translocon-mediated membrane insertion free energies of 357 systematically designed peptides. On the basis of this data set, we have developed MINS2, a novel sequence-based computational method for predicting the membrane insertion free energies of protein sequences. A benchmark analysis of MINS2 shows that MINS2 signi.cantly outperforms previously proposed methods. Importantly, the application of MINS2 to known membrane protein structures shows that a better prediction of membrane insertion free energies does not lead to a better prediction of transmembrane segments of polytopic membrane proteins. A web server for MINS2 is publicly available at http://service.bioinformatik.uni-saarland.de/mins. Supplementary data are available at Bioinformatics online.
NASA Astrophysics Data System (ADS)
Khosla, Deepak; Huber, David J.; Martin, Kevin
2017-05-01
This paper† describes a technique in which we improve upon the prior performance of the Rapid Serial Visual Presentation (RSVP) EEG paradigm for image classification though the insertion of visual attention distracters and overall sequence reordering based upon the expected ratio of rare to common "events" in the environment and operational context. Inserting distracter images maintains the ratio of common events to rare events at an ideal level, maximizing the rare event detection via P300 EEG response to the RSVP stimuli. The method has two steps: first, we compute the optimal number of distracters needed for an RSVP stimuli based on the desired sequence length and expected number of targets and insert the distracters into the RSVP sequence, and then we reorder the RSVP sequence to maximize P300 detection. We show that by reducing the ratio of target events to nontarget events using this method, we can allow RSVP sequences with more targets without sacrificing area under the ROC curve (azimuth).
[Cochlear implantation through the middle fossa approach].
Szyfter, W; Colletti, V; Pruszewicz, A; Kopeć, T; Szymiec, E; Kawczyński, M; Karlik, M
2001-01-01
The inner part of cochlear implant is inserted into inner ear during surgery through mastoid and middle ear. It is a classical method, used in the majority cochlear centers in the world. This is not a suitable method in case of chronic otitis media and middle ear malformation. In these cases Colletti proposed the middle fossa approach and cochlear implant insertion omitting middle ear structures. In patient with bilateral chronic otitis media underwent a few ears operations without obtaining dry postoperative cavity. Cochlear implantation through the middle fossa approach was performed in this patient. The bone fenster was cut, temporal lobe was bent and petrosus pyramid upper surface was exposed. When the superficial petrosal greater nerve, facial nerve and arcuate eminence were localised, the cochlear was open in the basal turn and electrode were inserted. The patient achieves good results in the postoperative speech rehabilitation. It confirmed Colletti tesis that deeper electrode insertion in the cochlear implantation through the middle fossa approach enable use of low and middle frequencies, which are very important in speech understanding.
Highly Compact Circulators in Square-Lattice Photonic Crystal Waveguides
Jin, Xin; Ouyang, Zhengbiao; Wang, Qiong; Lin, Mi; Wen, Guohua; Wang, Jingjing
2014-01-01
We propose, demonstrate and investigate highly compact circulators with ultra-low insertion loss in square-lattice- square-rod-photonic-crystal waveguides. Only a single magneto- optical square rod is required to be inserted into the cross center of waveguides, making the structure very compact and ultra efficient. The square rods around the center defect rod are replaced by several right-angled-triangle rods, reducing the insertion loss further and promoting the isolations as well. By choosing a linear-dispersion region and considering the mode patterns in the square magneto-optical rod, the operating mechanism of the circulator is analyzed. By applying the finite-element method together with the Nelder-Mead optimization method, an extremely low insertion loss of 0.02 dB for the transmitted wave and ultra high isolation of 46 dB∼48 dB for the isolated port are obtained. The idea presented can be applied to build circulators in different wavebands, e.g., microwave or Tera-Hertz. PMID:25415417
Highly compact circulators in square-lattice photonic crystal waveguides.
Jin, Xin; Ouyang, Zhengbiao; Wang, Qiong; Lin, Mi; Wen, Guohua; Wang, Jingjing
2014-01-01
We propose, demonstrate and investigate highly compact circulators with ultra-low insertion loss in square-lattice- square-rod-photonic-crystal waveguides. Only a single magneto- optical square rod is required to be inserted into the cross center of waveguides, making the structure very compact and ultra efficient. The square rods around the center defect rod are replaced by several right-angled-triangle rods, reducing the insertion loss further and promoting the isolations as well. By choosing a linear-dispersion region and considering the mode patterns in the square magneto-optical rod, the operating mechanism of the circulator is analyzed. By applying the finite-element method together with the Nelder-Mead optimization method, an extremely low insertion loss of 0.02 dB for the transmitted wave and ultra high isolation of 46 dB∼48 dB for the isolated port are obtained. The idea presented can be applied to build circulators in different wavebands, e.g., microwave or Tera-Hertz.
Histological observation for needle-tissue interactions.
Nakagawa, Yoshiyuki; Koseki, Yoshihiko
2013-01-01
We histologically investigated tissue fractures and deformations caused by ex vivo needle insertions. The tissue was formalin-fixed while the needle remained in the tissue. Following removal of the needle, the tissue was microtomed, stained, and observed microscopically. This method enabled observations of cellular and tissular conditions where deformations caused by needle insertions were approximately preserved. For this study, our novel method presents preliminary findings related with tissue fractures and the orientation of needle blade relative to muscle fibers. When the needle blade was perpendicular to the muscle fiber, transfiber fractures and relatively large longitudinal deformations occurred. When the needle blade was parallel to the muscle fiber, interfiber fractures and relatively small longitudinal deformations occurred. This made a significant difference in the resistance force of the needle insertions.
Rigid spine reinforced polymer microelectrode array probe and method of fabrication
Tabada, Phillipe; Pannu, Satinderpall S
2014-05-27
A rigid spine-reinforced microelectrode array probe and fabrication method. The probe includes a flexible elongated probe body with conductive lines enclosed within a polymeric material. The conductive lines connect microelectrodes found near an insertion end of the probe to respective leads at a connector end of the probe. The probe also includes a rigid spine, such as made from titanium, fixedly attached to the probe body to structurally reinforce the probe body and enable the typically flexible probe body to penetrate and be inserted into tissue, such as neural tissue. By attaching or otherwise fabricating the rigid spine to connect to only an insertion section of the probe body, an integrally connected cable section of the probe body may remain flexible.
Linear motion device and method for inserting and withdrawing control rods
Smith, J.E.
Disclosed is a linear motion device and more specifically a control rod drive mechanism (CRDM) for inserting and withdrawing control rods into a reactor core. The CRDM and method disclosed is capable of independently and sequentially positioning two sets of control rods with a single motor stator and rotor. The CRDM disclosed can control more than one control rod lead screw without incurring a substantial increase in the size of the mechanism.
Correction of hypermobile flatfoot in children by molded insert.
Bordelon, R L
1980-11-01
One hundred feet in 50 children between the ages of 3 and 9 years with a diagnosis of idiopathic hypermobile flatfoot had a custom-molded insert ordered. A specific method of casting, correcting the various components of the deformity was utilized. An 1/8-inch polypropolene insert was fabricated from the positive cast. The insert was worn in leather shoes with a long counter, steel shank, and Thomas heel. The flatfoot was evaluated and classified by measurement of the talometatarsal angle on a standing lateral X-ray. The insert was fabricated so that the standing lateral talometatarsal angle was corrected to neutral with the insert on the foot and the foot in the shoe. The preliminary reports indicate that a correction can be obtained at the rate of 0.41 degrees per month or approximately 5 degrees per year. There was no significant loss of motion of the foot or the ankle. Perhaps this regimen may be utilized in those children with a hypermobile flatfoot for whom treatment is advised.
Characterization of GM events by insert knowledge adapted re-sequencing approaches
Yang, Litao; Wang, Congmao; Holst-Jensen, Arne; Morisset, Dany; Lin, Yongjun; Zhang, Dabing
2013-01-01
Detection methods and data from molecular characterization of genetically modified (GM) events are needed by stakeholders of public risk assessors and regulators. Generally, the molecular characteristics of GM events are incomprehensively revealed by current approaches and biased towards detecting transformation vector derived sequences. GM events are classified based on available knowledge of the sequences of vectors and inserts (insert knowledge). Herein we present three insert knowledge-adapted approaches for characterization GM events (TT51-1 and T1c-19 rice as examples) based on paired-end re-sequencing with the advantages of comprehensiveness, accuracy, and automation. The comprehensive molecular characteristics of two rice events were revealed with additional unintended insertions comparing with the results from PCR and Southern blotting. Comprehensive transgene characterization of TT51-1 and T1c-19 is shown to be independent of a priori knowledge of the insert and vector sequences employing the developed approaches. This provides an opportunity to identify and characterize also unknown GM events. PMID:24088728
Characterization of GM events by insert knowledge adapted re-sequencing approaches.
Yang, Litao; Wang, Congmao; Holst-Jensen, Arne; Morisset, Dany; Lin, Yongjun; Zhang, Dabing
2013-10-03
Detection methods and data from molecular characterization of genetically modified (GM) events are needed by stakeholders of public risk assessors and regulators. Generally, the molecular characteristics of GM events are incomprehensively revealed by current approaches and biased towards detecting transformation vector derived sequences. GM events are classified based on available knowledge of the sequences of vectors and inserts (insert knowledge). Herein we present three insert knowledge-adapted approaches for characterization GM events (TT51-1 and T1c-19 rice as examples) based on paired-end re-sequencing with the advantages of comprehensiveness, accuracy, and automation. The comprehensive molecular characteristics of two rice events were revealed with additional unintended insertions comparing with the results from PCR and Southern blotting. Comprehensive transgene characterization of TT51-1 and T1c-19 is shown to be independent of a priori knowledge of the insert and vector sequences employing the developed approaches. This provides an opportunity to identify and characterize also unknown GM events.
Human Lamina Cribrosa Insertion and Age
Sigal, Ian A.; Flanagan, John G.; Lathrop, Kira L.; Tertinegg, Inka; Bilonick, Richard
2012-01-01
Purpose. To test the hypothesis that in healthy human eyes the lamina cribrosa (LC) insertion into the pia mater increases with age. Methods. The optic nerve heads (ONHs) of donor eyes fixed at either 5 or 50 mm Hg of IOP were sectioned, stained, and imaged under bright- and dark-field conditions. A 3-dimensional (3D) model of each ONH was reconstructed. From the 3D models we measured the area of LC insertion into the peripapillary scleral flange and into the pia, and computed the total area of insertion and fraction of LC inserting into the pia. Linear mixed effect models were used to determine if the measurements were associated with age or IOP. Results. We analyzed 21 eyes from 11 individuals between 47 and 91 years old. The LC inserted into the pia in all eyes. The fraction of LC inserting into the pia (2.2%–29.6%) had a significant decrease with age (P = 0.049), which resulted from a nonsignificant increase in the total area of LC insertion (P = 0.41) and a nonsignificant decrease in the area of LC insertion into the pia (P = 0.55). None of the measures was associated with fixation IOP (P values 0.44–0.81). Differences between fellow eyes were smaller than differences between unrelated eyes. Conclusions. The LC insertion into the pia mater is common in middle-aged and older eyes, and does not increase with age. The biomechanical and vascular implications of the LC insertion into the pia mater are not well understood and should be investigated further. PMID:22956611
Ioannou, Christopher; Knight, Matthew; Daniele, Luca; Flueckiger, Lee; Tan, Ezekiel S L
2016-10-17
The objective of this study is to analyse the effectiveness of the surgical torque limiter during operative use. The study also investigates the potential differences in torque between hand and drill-based screw insertion into locking plates using a standardised torque limiter. Torque for both hand and power screw insertion was measured through a load cell, registering 6.66 points per second. This was performed in a controlled environment using synthetic bone, a locking plate and locking screws to simulate plate fixation. Screws were inserted by hand and by drill with torque values measured. The surgical torque limiter (1.5 Nm) was effective as the highest recorded reading in the study was 1.409 Nm. Comparatively, there is a statistically significant difference between screw insertion methods. Torque produced for manually driven screw insertion into locking plates was 1.289 Nm (95 % CI 1.269-1.308) with drill-powered screw insertion at 0.740 Nm (95 % CI 0.723-0.757). The surgical torque limiter proved to be effective as per product specifications. Screws inserted under power produce significantly less torque when compared to manual insertion by hand. This is likely related to the mechanism of the torque limiter when being used at higher speeds for which it was designed. We conclude that screws may be inserted using power to the plate with the addition of a torque limiter. It is recommended that all screws inserted by drill be hand tightened to achieve adequate torque values.
NASA Astrophysics Data System (ADS)
Sikarwar, Nidhi
The noise produced by the low bypass ratio turbofan engines used to power fighter aircraft is a problem for communities near military bases and for personnel working in close proximity to the aircraft. For example, carrier deck personnel are subject to noise exposure that can result in Noise-Induced Hearing Loss which in-turn results in over a billion dollars of disability payments by the Veterans Administration. Several methods have been proposed to reduce the jet noise at the source. These methods include microjet injection of air or water downstream of the jet exit, chevrons, and corrugated nozzle inserts. The last method involves the insertion of corrugated seals into the diverging section of a military-style convergent-divergent jet nozzle (to replace the existing seals). This has been shown to reduce both the broadband shock-associated noise as well as the mixing noise in the peak noise radiation direction. However, the original inserts were designed to be effective for a take-off condition where the jet is over-expanded. The nozzle performance would be expected to degrade at other conditions, such as in cruise at altitude. A new method has been proposed to achieve the same effects as corrugated seals, but using fluidic inserts. This involves injection of air, at relatively low pressures and total mass flow rates, into the diverging section of the nozzle. These fluidic inserts" deflect the flow in the same way as the mechanical inserts. The fluidic inserts represent an active control method, since the injectors can be modified or turned off depending on the jet operating conditions. Noise reductions in the peak noise direction of 5 to 6 dB have been achieved and broadband shock-associated noise is effectively suppressed. There are multiple parameters to be considered in the design of the fluidic inserts. This includes the number and location of the injectors and the pressures and mass flow rates to be used. These could be optimized on an ad hoc basis with multiple experiments or numerical simulations. Alternatively an inverse design method can be used. An adjoint optimization method can be used to achieve the optimum blowing rate. It is shown that the method works for both geometry optimization and active control of the flow in order to deflect the flow in desirable ways. An adjoint optimization method is described. It is used to determine the blowing distribution in the diverging section of a convergent-divergent nozzle that gives a desired pressure distribution in the nozzle. Both the direct and adjoint problems and their associated boundary conditions are developed. The adjoint method is used to determine the blowing distribution required to minimize the shock strength in the nozzle to achieve a known target pressure and to achieve close to an ideally expanded flow pressure. A multi-block structured solver is developed to calculate the flow solution and associated adjoint variables. Two and three-dimensional calculations are performed for internal and external of the nozzle domains. A two step MacCormack scheme based on predictor- corrector technique is was used for some calculations. The four and five stage Runge-Kutta schemes are also used to artificially march in time. A modified Runge-Kutta scheme is used to accelerate the convergence to a steady state. Second order artificial dissipation has been added to stabilize the calculations. The steepest decent method has been used for the optimization of the blowing velocity after the gradients of the cost function with respect to the blowing velocity are calculated using adjoint method. Several examples are given of the optimization of blowing using the adjoint method.
Kim, Jong-Hak; Lee, Jun Seop
2013-01-01
Background Continuous epidural anesthesia is useful for endoscopic urologic surgery, as mostly performed in the elderly patients. In such a case, it is necessary to obtain successful sacral anesthesia, and the insertion of epidural catheter in the caudad direction may be needed. However, continuous epidural catherization has been related to paresthesias. This study aimed to evaluate the effects of the direction of the catheter insertion on the incidence of paresthesias in the elderly patients. Methods Two hundred elderly patients scheduled for endoscopic urologic surgery were enrolled. The epidural catheter was inserted at L2-3, L3-4, and L4-5 using the Tuohy needle. In Group I (n = 100), the Tuohy needle with the bevel directed the cephalad during the catheter insertion. In Group II (n = 100), it directed the caudad. During the catheter insertion, an anesthesiologist evaluated the presence of paresthesias and the ease or difficulty during the catheter insertion. Results In Group I (n = 97), 15.5% of the patients had paresthesias versus 18.4% in Group II (n = 98), and there was no significant difference between the two groups. In paresthesia depending on the insertion site and the ease or difficulty during the catheter insertion, there were no significant differences between the two groups. Conclusions Our results concluded that the direction of epidural catheter insertion did not significantly influence the incidence of paresthesias in the elderly patients. PMID:23741568
Ono, Satoshi; Niimi, Keiko; Fujishiro, Mitsuhiro; Nakao, Tomoko; Suzuki, Kazushi; Ohike, Yumiko; Kodashima, Shinya; Yamamichi, Nobutake; Yamazaki, Tsutomu; Koike, Kazuhiko
2013-01-01
AIM: To evaluate the effects of choice of insertion route and ultrathin endoscope types. METHODS: This prospective study (January-June 2012) included 882 consecutive patients who underwent annual health checkups. Transnasal esophagogastroduodenoscopy (EGD) was performed in 503 patients and transoral EGD in 235 patients using six types of ultrathin endoscopes. Patients were given a choice of insertion route, either transoral or transnasal, prior to EGD examination. For transoral insertion, the endoscope was equipped with a thin-type mouthpiece and tongue depressor. Conscious sedation was not used for any patient. EGD-associated discomfort was assessed using a visual analog scale (VAS; no discomfort 0- maximum discomfort 10). RESULTS: Rates of preference for transnasal insertion were significantly higher in male (male/female 299/204 vs 118/117) and younger patients (56.8 ± 11.2 years vs 61.3 ± 13.0 years), although no significant difference was found in VAS scores between transoral and transnasal insertion (3.9 ± 2.3 vs 4.1 ± 2.5). Multivariate analysis revealed that gender, age, operator, and endoscope were independent significant predictors of VAS for transnasal insertion, although gender, age, and endoscope were those for transoral insertion. Further analysis revealed only the endoscopic flexibility index (EFI) as an independent significant predictor of VAS for transnasal insertion. Both EFI and tip diameter were independent significant predictors of VAS for transoral insertion. CONCLUSION: Flexibility of ultrathin endoscopes can be a predictor of EGD-associated discomfort, especially in transnasal insertion. PMID:23858379
Inserting new technology into small missions
NASA Technical Reports Server (NTRS)
Deutsch, L. J.
2001-01-01
Part of what makes small missions small is that they have less money. Executing missions at low cost implies extensive use of cost sharing with other missions or use of existing solutions. Luckily, there are methods for creating new technology and inserting it into faster-better-cheaper missions.
Harris, Chad T; Haw, Dustin W; Handler, William B; Chronik, Blaine A
2013-09-01
Eddy currents are generated in MR by the use of rapidly switched electromagnets, resulting in time varying and spatially varying magnetic fields that must be either minimized or corrected. This problem is further complicated when non-cylindrical insert magnets are used for specialized applications. Interruption of the coupling between an insert coil and the MR system is typically accomplished using active magnetic shielding. A new method of actively shielding insert gradient and shim coils of any surface geometry by use of the boundary element method for coil design with a minimum energy constraint is presented. This method was applied to shield x- and z-gradient coils for two separate cases: a traditional cylindrical primary gradient with cylindrical shield and, to demonstrate its versatility in surface geometry, the same cylindrical primary gradients with a rectangular box-shaped shield. For the cylindrical case this method produced shields that agreed with analytic solutions. For the second case, the rectangular box-shaped shields demonstrated very good shielding characteristics despite having a different geometry than the primary coils. Copyright © 2013 Elsevier Inc. All rights reserved.
Effects of Single P-Element Insertions on Bristle Number and Viability in Drosophila Melanogaster
Lyman, R. F.; Lawrence, F.; Nuzhdin, S. V.; Mackay, TFC.
1996-01-01
Single P-element mutagenesis was used to construct 1094 lines with P[lArB] inserts on all three major chromosomes in an isogenic background previously free of P elements. The effects of insertions on bristle number and on viability were assessed by comparison to 392 control lines. The variance and effects of P-element inserts on bristle number and viability were larger than those inferred from spontaneous mutations. The distributions of effects on bristle number were symmetrical and highly leptokurtic, such that a few inserts with large effects caused most of the increase in variance. The distribution of effects on viability were negatively skewed and platykurtic. On average, the effects of P-element insertions on bristle number were partly recessive and on viability were completely recessive. P-element inserts with large effects on bristle number tended to have reduced viability, but the correlation between the absolute value of the effects on bristle number and on viability was not strong. Fifty P-element inserts tagging quantitative trait loci (QTLs) with large effects on bristle number were mapped cytogenetically. Two P-element-induced scabrous alleles and five extramacrochaetae alleles were generated. Single P-element mutagenesis is a powerful method for identifying QTLs at the level of genetic locus. PMID:8722781
Effects of single P-element insertions on bristle number and viability in Drosophila melanogaster.
Lyman, R F; Lawrence, F; Nuzhdin, S V; Mackay, T F
1996-05-01
Single P-element mutagenesis was used to construct 1094 lines with P[lArB] inserts on all three major chromosomes in an isogenic background previously free of P elements. The effects of insertions on bristle number and on viability were assessed by comparison to 392 control lines. The variance and effects of P-element inserts on bristle number and viability were larger than those inferred from spontaneous mutations. The distributions of effects on bristle number were symmetrical and highly leptokurtic, such that a few inserts with large effects caused most of the increase in variance. The distribution of effects on viability were negatively skewed and platykurtic. On average, the effects of P-element insertions on bristle number were partly recessive and on viability were completely recessive. P-element inserts with large effects on bristle number tended to have reduced viability, but the correlation between the absolute value of the effects on bristle number and on viability was not strong. Fifty P-element inserts tagging quantitative trait loci (QTLs) with large effects on bristle number were mapped cytogenetically. Two P-element-induced scabrous alleles and five extramacrochaetae alleles were generated. Single P-element mutagenesis is a powerful method for identifying QTLs at the level of genetic locus.
Antegrade Ureteral Stenting is a Good Alternative for the Retrograde Approach
van der Meer, Rutger W.; Weltings, Saskia; van Erkel, Arian R.; Roshani, Hossain; Elzevier, Henk W.; van Dijk, Lukas C.; van Overhagen, Hans
2017-01-01
Background/Aims Double J (JJ) stents for treating obstructive ureteral pathology are generally inserted through a retrograde route with cystoscopic guidance. Antegrade percutaneous insertion using fluoroscopy can be performed alternatively but is less known. Indications, success rate and complications of antegrade ureteral stenting were evaluated. Methods Data of consecutive patients in which antegrade ureteral stenting was performed were retrospectively analysed using the radiology information system and patient records. Patient characteristics, details of the antegrade JJ stent insertion procedure and registered complications were collected. Furthermore, it was investigated if prior to the antegrade procedure a retrograde attempt for JJ stent insertion was performed. Results Total 130 attempts for antegrade JJ stent insertion were performed in 100 patients. A percutaneous nephrostomy catheter had already been placed in the majority of kidneys (n = 109) for initial treatment of hydronephrosis. Most prevelant indication for a JJ stent was obstructive ureteral pathology due to malignancy (n = 63). A JJ stent was successfully inserted in 125 of 130 procedures. In 21 cases, previous retrograde ureteral stenting had failed but, subsequent antegrade ureteral stenting was successful. There were 8 procedure related complications; 6 infections, 1 false tract and 1 malposition. Conclusion Antegrade percutaneous insertion of a JJ stent is a good alternative for retrograde insertion. PMID:28785193
Kim, Min-Soo; Lee, Jeong-Rim; Shin, Yang-Sik; Chung, Ji-Won; Lee, Kyu-Ho; Ahn, Ki Ryang
2014-03-01
This single-center, prospective, randomized, double-blind, 2-arm, parallel group comparison trial was performed to establish whether the adult-sized laryngeal mask airway (LMA) Classic (The Laryngeal Mask Company Ltd, Henley-on-Thames, UK) could be used safely without any consideration of cuff hyperinflation when a cuff of the LMA Classic was inflated using half the maximum inflation volume or the resting volume before insertion of device. Eighty patients aged 20 to 70 years scheduled for general anesthesia using the LMA Classic were included. Before insertion, the cuff was partially filled with half the maximum inflation volume in the half volume group or the resting volume created by opening the pilot balloon valve to equalize with atmospheric pressure in the resting volume group. Several parameters regarding insertion, intracuff pressure, airway leak pressure, and leakage volume/fraction were collected after LMA insertion. The LMA Classic with a partially inflated cuff was successfully inserted in all enrolled patients. Both groups had the same success rate of 95% at the first insertion attempt. The half volume group had a lower mean intracuff pressure compared with the resting volume group (54.5 ± 16.1 cm H2O vs 61.8 ± 16.1 cm H2O; P = .047). There was no difference in airway leak pressure or leakage volume/fraction between the 2 groups under mechanical ventilation. The partially inflated cuff method using half the maximum recommended inflation volume or the resting volume is feasible with the adult-sized LMA Classic, resulting in a high success rate of insertion and adequate range of intracuff pressures. Copyright © 2014 Elsevier Inc. All rights reserved.
Zhang, Zeng-yan; Ji, Te; Zhu, Zhi-yong; Zhao, Hong-wei; Chen, Min; Xiao, Ti-qiao; Guo, Zhi
2015-01-01
Terahertz radiation is an electromagnetic radiation in the range between millimeter waves and far infrared. Due to its low energy and non-ionizing characters, THz pulse imaging emerges as a novel tool in many fields, such as material, chemical, biological medicine, and food safety. Limited spatial resolution is a significant restricting factor of terahertz imaging technology. Near field imaging method was proposed to improve the spatial resolution of terahertz system. Submillimeter scale's spauial resolution can be achieved if the income source size is smaller than the wawelength of the incoming source and the source is very close to the sample. But many changes were needed to the traditional terahertz time domain spectroscopy system, and it's very complex to analyze sample's physical parameters through the terahertz signal. A method of inserting a pinhole upstream to the sample was first proposed in this article to improve the spatial resolution of traditional terahertz time domain spectroscopy system. The measured spatial resolution of terahertz time domain spectroscopy system by knife edge method can achieve spatial resolution curves. The moving stage distance between 10 % and 90 Yo of the maximum signals respectively was defined as the, spatial resolution of the system. Imaging spatial resolution of traditional terahertz time domain spectroscopy system was improved dramatically after inserted a pinhole with diameter 0. 5 mm, 2 mm upstream to the sample. Experimental results show that the spatial resolution has been improved from 1. 276 mm to 0. 774 mm, with the increment about 39 %. Though this simple method, the spatial resolution of traditional terahertz time domain spectroscopy system was increased from millimeter scale to submillimeter scale. A pinhole with diameter 1 mm on a polyethylene plate was taken as sample, to terahertz imaging study. The traditional terahertz time domain spectroscopy system and pinhole inserted terahertz time domain spectroscopy system were applied in the imaging experiment respectively. The relative THz-power loss imaging of samples were use in this article. This method generally delivers the best signal to noise ratio in loss images, dispersion effects are cancelled. Terahertz imaging results show that the sample's boundary was more distinct after inserting the pinhole in front of, sample. The results also conform that inserting pinhole in front of sample can improve the imaging spatial resolution effectively. The theoretical analyses of the method which improve the spatial resolution by inserting a pinhole in front of sample were given in this article. The analyses also indicate that the smaller the pinhole size, the longer spatial coherence length of the system, the better spatial resolution of the system. At the same time the terahertz signal will be reduced accordingly. All the experimental results and theoretical analyses indicate that the method of inserting a pinhole in front of sample can improve the spatial resolution of traditional terahertz time domain spectroscopy system effectively, and it will further expand the application of terahertz imaging technology.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-23
... of showerhead and hand-held showerhead; removal of body sprays from the proposed showerhead... standardized test method to be used when verifying the mechanical retention of a showerhead flow control insert... Faucets 1. Definitions 2. Test Procedure for Showerhead Flow Control Insert [[Page 62971
Method of making a non-lead hollow point bullet
Vaughn, Norman L.; Lowden, Richard A.
2003-10-07
The method of making a non-lead hollow point bullet has the steps of a) compressing an unsintered powdered metal composite core into a jacket, b) punching a hollow cavity tip portion into the core, c) seating an insert, the insert having a hollow point tip and a tail protrusion, on top of the core such that the tail protrusion couples with the hollow cavity tip portion, and d) swaging the open tip of the jacket.
Molecular simulation of simple fluids and polymers in nanoconfinement
NASA Astrophysics Data System (ADS)
Rasmussen, Christopher John
Prediction of phase behavior and transport properties of simple fluids and polymers confined to nanoscale pores is important to a wide range of chemical and biochemical engineering processes. A practical approach to investigate nanoscale systems is molecular simulation, specifically Monte Carlo (MC) methods. One of the most challenging problems is the need to calculate chemical potentials in simulated phases. Through the seminal work of Widom, practitioners have a powerful method for calculating chemical potentials. Yet, this method fails for dense and inhomogeneous systems, as well as for complex molecules such as polymers. In this dissertation, the gauge cell MC method, which had previously been successfully applied to confined simple fluids, was employed and extended to investigate nanoscale fluids in several key areas. Firstly, the process of cavitation (the formation and growth of bubbles) during desorption of fluids from nanopores was investigated. The dependence of cavitation pressure on pore size was determined with gauge cell MC calculations of the nucleation barriers correlated with experimental data. Additional computational studies elucidated the role of surface defects and pore connectivity in the formation of cavitation bubbles. Secondly, the gauge cell method was extended to polymers. The method was verified against the literature results and found significantly more efficient. It was used to examine adsorption of polymers in nanopores. These results were applied to model the dynamics of translocation, the act of a polymer threading through a small opening, which is implicated in drug packaging and delivery, and DNA sequencing. Translocation dynamics was studied as diffusion along the free energy landscape. Thirdly, we show how computer simulation of polymer adsorption could shed light on the specifics of polymer chromatography, which is a key tool for the analysis and purification of polymers. The quality of separation depends on the physico-chemical mechanisms of polymer/pore interaction. We considered liquid chromatography at critical conditions, and calculated the dependence of the partition coefficient on chain length. Finally, solvent-gradient chromatography was modeled using a statistical model of polymer adsorption. A model for predicting separation of complex polymers (with functional groups or copolymers) was developed for practical use in chromatographic separations.
Park, Seung Hyun; Lee, Kang Ju; Lee, JiYong; Yoon, Jae Hyoung; Jo, Dong Hyun; Kim, Jeong Hun; Kang, Keonwook; Ryu, WonHyoung
2016-10-15
The sclera provides the structural support of the eye and protects the intraocular contents. Since it covers a large portion of the eye surface and has relatively high permeability for most drugs, the sclera has been used as a major pathway for drug administration. Recently, microneedle (MN) technology has shown the possibility of highly local and minimally-invasive drug delivery to the eye by MN insertion through the sclera or the suprachoroidal space. Although ocular MN needs to be inserted through the sclera, there has been no systematic study to understand the mechanical properties of the sclera, which are important to design ocular MNs. In this study, we investigated a MN-based method to measure the puncture resistance and fracture toughness of the sclera. To reflect the conditions of MN insertion into the sclera, force-displacement curves obtained from MN-insertion tests were used to estimate the puncture resistance and fracture toughness of sclera tissue. To understand the effect of the insertion conditions, dependency of the mechanical properties on insertion speeds, pre-strain of the sclera, and MN sizes were analyzed and discussed. Measurement of mechanical property of soft biological tissue is challenging due to variations between tissue samples or lack of well-defined measurement techniques. Although non-invasive measurement techniques such as nano/micro indentation were employed to locally measure the elastic modulus of soft biological materials, mechanical properties such as puncture resistance or fracture toughness, which requires "invasive" measurement and is important for the application of "microneedles or hypodermic needles", has not been well studied. In this work, we report minimally-invasive measurement of puncture resistance and fracture toughness of sclera using a double MN insertion method. Parametric studies showed that use of MN proved to be advantageous because of minimally-invasive insertion into tissue as well as higher sensitivity to sub-tissue architecture during the measurement. Copyright © 2016 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Chandler, John E; Lee, Cameron M; Babchanik, Alexander P; Melville, C David; Saunders, Michael D; Seibel, Eric J
2012-01-01
Purpose Direct visualization of pancreatic ductal tissue is critical for early diagnosis of pancreatic diseases and for guiding therapeutic interventions. A novel, ultrathin (5 Fr) scanning fiber endoscope (SFE) with tip-bending capability has been developed specifically to achieve high resolution imaging as a pancreatoscope during endoscopic retrograde cholangiopancreatography (ERCP). This device has potential to dramatically improve both diagnostic and therapeutic capabilities during ERCP by providing direct video feedback and tool guidance to clinicians. Methods Invasiveness of the new tip-bending SFE was evaluated by a performance comparison to ERCP guide wires, which are routinely inserted into the pancreatic duct during ERCP. An in vitro test model with four force sensors embedded in a synthetic pancreas was designed to detect and compare the insertion forces for 0.89 mm and 0.53 mm diameter guide wires as well as the 1.7 mm diameter SFE. Insertions were performed through the working channel of a therapeutic duodenoscope for the two types of guide wires and using a statistically similar direct insertion method for comparison to the SFE. Results Analysis of the forces detected by the sensors showed the smaller diameter 0.53 mm wire produced significantly less average and maximum forces during insertion than the larger diameter 0.89 mm wire. With the use of tip-bending and optical visualization, the 1.7 mm diameter SFE produced significantly less average force during insertion than the 0.89 mm wire at every sensor, despite its larger size. It was further shown that the use of tip-bending with the SFE significantly reduced the forces at all sensors, compared to insertions when tip-bending was not used. Conclusion Combining high quality video imaging with two-axis tip-bending allows a larger diameter guide wire-style device to be inserted into the pancreatic duct during ERCP with improved capacity to perform diagnostics and therapy. PMID:23166452
Computerized planning of prostate cryosurgery using variable cryoprobe insertion depth.
Rossi, Michael R; Tanaka, Daigo; Shimada, Kenji; Rabin, Yoed
2010-02-01
The current study presents a computerized planning scheme for prostate cryosurgery using a variable insertion depth strategy. This study is a part of an ongoing effort to develop computerized tools for cryosurgery. Based on typical clinical practices, previous automated planning schemes have required that all cryoprobes be aligned at a single insertion depth. The current study investigates the benefit of removing this constraint, in comparison with results based on uniform insertion depth planning as well as the so-called "pullback procedure". Planning is based on the so-called "bubble-packing method", and its quality is evaluated with bioheat transfer simulations. This study is based on five 3D prostate models, reconstructed from ultrasound imaging, and cryoprobe active length in the range of 15-35 mm. The variable insertion depth technique is found to consistently provide superior results when compared to the other placement methods. Furthermore, it is shown that both the optimal active length and the optimal number of cryoprobes vary among prostate models, based on the size and shape of the target region. Due to its low computational cost, the new scheme can be used to determine the optimal cryoprobe layout for a given prostate model in real time. Copyright 2008 Elsevier Inc. All rights reserved.
Advantages and disadvantages of surgical placement of PD catheters with regard to other methods.
Stegmayr, B
2006-01-01
Peritoneal dialysis is underused for various reasons. One reason may be problems with insertion of catheters for access. Another reason is the delayed start (break-in period) of about 2 weeks after operation. This review describes various approaches to the insertion of a peritoneal dialysis catheter. The optimal conditions to strive for are given as is an overview of various techniques. This article favours surgical placement while others might prefer other techniques. Described is the use a 3-purse string suture technique that allows immediate start of dialysis after catheter insertion both for acute dialysis indications as well as for acute start in chronic dialysis patients. A key to lesser complications is to establish a team devoted to the insertions rather than to allow various physicians to perform insertions as a training procedure. An optimal access is one of the important life lines for these patients.
Double Internal Limiting Membrane Insertion for Macular Hole-Associated Retinal Detachment
Chen, San-Ni
2017-01-01
Purpose To describe a modified technique of internal limiting membrane (ILM) insertion for macular hole- (MH-) associated retinal detachment (RD) in highly myopic eyes. Methods Nine eyes underwent pars plana vitrectomy, cortical vitreous removal, and fovea-sparing ILM peeling. Double ILM insertion into the hole was performed with inverted perifoveal ILM and a free ILM flap followed by air-fluid exchange. Results Two of the 9 eyes had perifoveal ILM partially torn after cortical vitreous or epiretinal removal. All eyes had the ILM plug stabilized within the MH after double ILM insertion. Postoperatively, MH was sealed with the retina reattached in all the eyes. Conclusion Double ILM insertion may further secure the ILM flap in place in the eyes with MH-associated RD, especially in cases in which insufficient perifoveal ILM was left. This trial is registered with the clinical registration number Clinicaltrials.gov NCT03174639. PMID:28845304
Rectal suppository: commonsense and mode of insertion.
Abd-el-Maeboud, K H; el-Naggar, T; el-Hawi, E M; Mahmoud, S A; Abd-el-Hay, S
1991-09-28
Rectal suppository is a well-known form of medication and its use is increasing. The commonest shape is one with an apex (pointed end) tapering to a base (blunt end). Because of a general lack of information about mode of insertion, we asked 360 lay subjects (Egyptians and non-Egyptians) and 260 medical personnel (physicians, pharmacists, and nurses) by questionnaire which end they inserted foremost. Apart from 2 individuals, all subjects suggested insertion with the apex foremost. Commonsense was the most frequent basis for this practice (86.9% of lay subjects and 84.6% of medical personnel) followed by information from a relative, a friend, or medical personnel, or from study at medical school. Suppository insertion with the base or apex foremost was compared in 100 subjects (60 adults, 40 infants and children). Retention with the former method was more easily achieved in 98% of the cases, with no need to introduce a finger in the anal canal (1% vs 83%), and lower expulsion rate (0% vs 3%). The designer of the "torpedo-shaped" suppository suggested its insertion with apex foremost. Our data suggest that a suppository is better inserted with the base foremost. Reversed vermicular contractions or pressure gradient of the anal canal might press it inwards.
Dinesh Kumar, K. K.; Bhardwaj, Neerja; Yaddanapudi, Sandhya
2017-01-01
Background and Aims: It is not known whether trapezius squeeze test (TPZ) is a better clinical test than jaw thrust (JT) to assess laryngeal mask airway (LMA) insertion conditions in children under sevoflurane anesthesia. Material and Methods: After the Institutional Ethics Committee approval and written informed parental consent, 124 American Society of Anesthesiologists I and II children of 2–8 years of age undergoing minor surgical procedures were randomized into TPZ and JT groups. The children were induced with 8% sevoflurane in oxygen at a fresh gas flow of 4 L/min. TPZ or JT was performed after 1 min of start of sevoflurane and then every 20 s till the test was negative, when end-tidal (ET) sevoflurane concentration was noted. Classic LMA of requisite size was inserted by a blinded anesthetist and conditions at the insertion of LMA, insertion time, and the number of attempts of LMA insertion were recorded. Results: The mean LMA insertion time was significantly longer (P < 0.001) for TPZ (145 ± 28.7 sec) compared to JT group (111.8 ± 31.0 sec). ET sevoflurane concentration at the time of LMA insertion was comparable in the two groups. LMA insertion conditions were similar in the two groups. There was no difference between the two groups regarding total number of attempts of LMA insertion. Heart rate (HR) decreased in both groups after LMA insertion (P < 0.001) but TPZ group had significantly lower HR compared with the JT group up to 5 min after LMA insertion (P = 0.03). Conclusion: Both JT and TPZ are equivalent clinical indicators in predicting the optimal conditions of LMA insertion in spontaneously breathing children; however, it takes a longer time to achieve a negative TPZ squeeze test. PMID:28413275
Ober, Julian; Walker, Tilman; Bergdolt, Christian; Friedrich, Mirco; Müller-Stich, Beat Peter; Forchheim, Franziska; Fischer, Christian; Schmidmaier, Gerhard; Tanner, Michael C
2018-01-01
Background The insertion of a chest tube should be as quick and accurate as possible to maximize the benefit and minimize possible complications for the patient. Therefore, comprehensive training and assessment before an emergency situation are essential for proficiency in chest tube insertion. Serious games have become more prevalent in surgical training because they enable students to study and train a procedure independently, and errors made have no effect on patients. However, up-to-date evidence regarding the effect of serious games on performance in procedures in emergency medicine remains scarce. Objective The aim of this study was to investigate the serious gaming approach in teaching medical students an emergency procedure (chest tube insertion) using the app Touch Surgery and a modified objective structural assessment of technical skills (OSATS). Methods In a prospective, rater-blinded, randomized controlled trial, medical students were randomized into two groups: intervention group or control group. Touch Surgery has been established as an innovative and cost-free app for mobile devices. The fully automatic software enables users to train medical procedures and afterwards self-assess their training effort. The module chest tube insertion teaches each key step in the insertion of a chest tube and enables users the meticulous application of a chest tube. In contrast, the module “Thoracocentesis” discusses a basic thoracocentesis. All students attended a lecture regarding chest tube insertion (regular curriculum) and afterwards received a Touch Surgery training lesson: intervention group used the module chest tube insertion and the control group used Thoracocentesis as control training. Participants’ performance in chest tube insertion on a porcine model was rated on-site via blinded face-to-face rating and via video recordings using a modified OSATS tool. Afterwards, every participant received an individual questionnaire for self-evaluation. Here, trainees gave information about their individual training level, as well as previous experiences, gender, and hobbies. Primary end point was operative performance during chest tube insertion by direct observance. Results A total of 183 students enrolled, 116 students participated (63.4%), and 21 were excluded because of previous experiences in chest tube insertion. Students were randomized to the intervention group (49/95, 52%) and control group (46/95, 48%). The intervention group performed significantly better than the control group (Intervention group: 38.0 [I50=7.0] points; control group: 30.5 [I50=8.0] points; P<.001). The intervention group showed significantly improved economy of time and motion (P=.004), needed significantly less help (P<.001), and was more confident in handling of instruments (P<.001) than the control group. Conclusions The results from this study show that serious games are a valid and effective tool in education of operative performance in chest tube insertion. We believe that serious games should be implemented in the surgical curriculum, as well as residency programs, in addition to traditional learning methods. Trial Registration German Clinical Trials Register (DRKS) DRKS00009994; https://www.drks.de/drks_web/navigate.do?navigationId=trial.HTML&TRIAL_ID=DRKS00009994 (Archived by Webcite at http://www.webcitation.org/6ytWF1CWg) PMID:29784634
[Data Mining-revealed Characteristics of Clinical Application of Scalp Acupuncture].
Wang, Qiong; Xing, Hai-Jiao; Bao, Na; Kong, Ling-Juan; Jia, Ye-Juan; Yang, Ke; Sun, Yan-Hui; Wang, Jian-Ling; Shi, Jing; Li, Xiao-Feng; Xu, Jing; Zhang, Xuan-Ping; Zhang, Xin; Jia, Chun-Sheng; Li, Ren-Ling
2018-03-25
To explore the regularity and characteristics of clinical application of scalp acupuncture therapy for different types of clinical conditions so as to provide a reference for clinical practice. In the present study, "head acupuncture" and"scalp acupuncture" were used as the keywords to search papers and academic dissertations having definite standards for diagnosis and therapeutic effect assessment and published in journals and academic conferences collected in database China National Knowledge Internet(CNKI) from January 1 of 1959 to December 31 of 2016, followed by constructing a database after sorting, screening, recording, extracting, and statistical analysis by using a computer. Then, the data mining was conducted for summarizing the indications of disease categories, involved medical departments, needle-insertion methods, needle manipulation techniques, academic schools, and clinical efficacy of scalp acupuncture therapy. As a result, a total of 587 papers met our including criteria were analyzed. The scalp acupuncture therapy was widely employed in the treatment of various clinical conditions of different departments, with the application frequency being the internal medicine (438 times), surgery (75 times), pediatrics (44 times), etc. Of the indicated 102 types of clinical problems, 55 belong to the internal medicine, constituting of 53.92%, particularly the cerebral apoplexy and its sequelae with the top application frequency being 102 and 115 times, respectively. In terms of needle inserting methods mentioned in partial papers (most papers do not mention), fingernail-pressing-aided needle insertion, needle-twirling insertion, fingers-squeezed-needle insertion, particularly the swiftly rotating needle insertion and rapid needle-propelling insertion were most commonly used.Regarding the needle manipulation method, rapid needle twirling technique was frequently employed, usually at a frequency of approximately 200 times per min. In regard to the academic schools, JIAO Shun-fa's scalp acupuncture system was most frequently used, followed by the international standardized scalp acupuncture. The therapeutic effect of scalp acupuncture is effective in the treatment of different conditions of various departments, especially those of the dermatology and gynecology. Scalp acupuncture has superiority in the treatment disorders of the internal medicine and has been demonstrated to have positive effects for many types of problems, particularly for apoplexy and its sequelae. Rapid needle-propelling insertion and rapid needle-twirling technique are often employed.
Crockett, Amy H; Pickell, Lesley Bundon; Heberlein, Emily C; Billings, Deborah L; Mills, Benjie
2017-01-01
This study aims to document 6- and 12-month removal rates for women receiving the contraceptive implant inpatient postpartum versus those receiving the same contraceptive method during an outpatient visit, in a setting where postpartum inpatient long-acting reversible contraceptive (LARC) services (devices plus provider insertion costs) are reimbursed by Medicaid. We conducted a retrospective cohort study among Medicaid-enrolled women using medical record review for all women receiving the etonogestrel implant between July 1, 2007 and June 30, 2014. We compared the percentage of women with the implant removed at 6 and 12 months as well as reasons for early removal, for inpatient postpartum implant insertions vs. delayed postpartum or interval outpatient implant insertions. A total of 4% of women (34/776 insertions) had documented implant removal within 6 months post-insertion, with no difference between postpartum inpatient and outpatient (delayed postpartum or interval). A total of 12% (62/518 insertions) of women had documented implant removal within 12 months. A lower percentage of women with postpartum inpatient insertions had the implant removed at 12 months post-insertion, compared to outpatient insertions (7% vs. 14%, p=.04). After controlling for age, parity, race and body mass index, women with postpartum inpatient insertions were less likely to have the implant removed within 12 months (OR=0.44, 95% CI 0.20-0.97). The most commonly stated reason for removal was abnormal uterine bleeding, regardless of insertion timing. In a setting with a Medicaid policy that covers postpartum inpatient LARC insertion, a low percentage of women who received an implant immediately postpartum had it removed within 1 year of insertion. A Medicaid payment policy that removes institutional barriers to offering postpartum inpatient contraceptive implants to women free-of-charge may facilitate meeting women's desires and intentions to delay subsequent pregnancy, as evidenced by low removal rates up to 12 months post-insertion. Further research with women is needed to assess how these services meet their postpartum contraceptive needs and desires to postpone or prevent subsequent pregnancy. Copyright © 2016 Elsevier Inc. All rights reserved.
Oosthuizen, GV; Sartorius, B; Keene, C; Clarke, DL
2014-01-01
Introduction Intercostal chest drain (ICD) insertion is a commonly performed procedure in trauma and may be associated with significant morbidity. Methods This was a retrospective review of ICD complications in a major trauma service in South Africa over a four-year period from January 2010 to December 2013. Results A total of 1,050 ICDs were inserted in 1,006 patients, of which 91% were male. The median patient age was 24 years (interquartile range [IQR]: 20–29 years). There were 962 patients with unilateral ICDs and 44 with bilateral ICDs. Seventy-five per cent (758/1,006) sustained penetrating trauma and the remaining 25% (248/1006) sustained blunt trauma. Indications for ICD insertion were: haemopneumothorax (n=338), haemothorax (n=314), simple pneumothorax (n=265), tension pneumothorax (n=79) and open pneumothorax (n=54). Overall, 203 ICDs (19%) were associated with complications: 18% (36/203) were kinked, 18% (36/203) were inserted subcutaneously, 13% (27/203) were too shallow and in 7% (14/203) there was inadequate fixation resulting in dislodgement. Four patients (2%) sustained visceral injuries and two sustained vascular injuries. Forty-one per cent (83/203) were inserted outside the ‘triangle of safety’ but without visceral or vascular injuries. One patient had the ICD inserted on the wrong side. Junior doctors inserted 798 ICDs (76%) while senior doctors inserted 252 (24%). Junior doctors had a significantly higher complication rate (24%) compared with senior doctors (5%) (p<0.001). There was no mortality as a direct result of ICD insertion. Conclusions ICD insertion is associated with a high rate of complications. These complications are significantly higher when junior doctors perform the procedure. A multifaceted quality improvement programme is needed to improve the situation. PMID:25350185
Gira, Joseph P; Sampson, Reginald; Silverstein, Steven M; Walters, Thomas R; Metzinger, Jamie Lynne; Talamo, Jonathan H
2017-01-01
Purpose The purpose of this study is to evaluate the patient experience of sustained release dexamethasone intracanalicular insert (Dextenza™) following cataract surgery as part of a Phase III clinical trial program. Methods This cross-sectional, qualitative evaluation involved individual interviews lasting approximately 45 minutes. Patients from four US investigational study sites who had previously received an insert were enrolled. There were no predesignated end points; this was a qualitative survey seeking a deeper understanding of patient experience. Results Twenty-five patients were interviewed. Most patients (92%) reported the highest level of satisfaction grade with regard to overall product satisfaction. All patients described the insert as comfortable. Most patients (96%) described their overall experience with the insert as very convenient or extremely convenient. Twenty-two of 23 (96%) participants rated their experience with the insert as “very” or “extremely convenient”, compared to previous topical therapy, and 88% of patients stated that if they were to undergo cataract surgery again, they would request the insert. When asked if they would recommend the insert to family members or friends, 92% stated they would. The survey found that 84% of participants would be willing to pay more for the insert than for eye drop therapy. Conclusion The dexamethasone insert was found by patients to be highly favorable with regard to overall satisfaction, convenience, and comfort. The insert was well received and largely preferred over topical therapy alternatives following surgery. More extensive evaluation of the patient experience is warranted, and future studies should help inform design of the next generation of sustained release drug delivery systems. PMID:28331295
Continuous air monitor filter changeout apparatus
Rodgers, John C [Santa Fe, NM
2008-07-15
An apparatus and corresponding method for automatically changing out a filter cartridge in a continuous air monitor. The apparatus includes: a first container sized to hold filter cartridge replacements; a second container sized to hold used filter cartridges; a transport insert connectively attached to the first and second containers; a shuttle block, sized to hold the filter cartridges that is located within the transport insert; a transport driver mechanism means used to supply a motive force to move the shuttle block within the transport insert; and, a control means for operating the transport driver mechanism.
Implanon NXT: Expert tips for best-practice insertion and removal.
Pearson, Suzanne; Stewart, Mary; Bateson, Deborah
2017-03-01
The single rod etonogestrel contraceptive implant is available in Australia as Implanon NXT. It is a highly effective, long-acting reversible contraceptive method, which is suitable for most women across the reproductive lifespan. This article provides practical advice for clinicians who already insert and remove the contraceptive implant, as well as advice for those who have not yet acquired this procedural skill. Contraceptive implant procedures are usually performed in the general practice setting. Clinicians can support women in making an informed choice to have an implant by providing information about their benefits, side effects and risks, and timely access to insertion. Training in the procedures and compliance with procedural instructions are essential to minimise risks, including deep insertion and damage to neurovascular structures.
Fishtail on a line technique for capsular tension ring insertion.
Rixen, Jordan J; Oetting, Thomas A
2014-07-01
We describe a capsular tension ring (CTR) insertion technique that is a modification of the previously described fishtail technique. A suture line is used to pull the leading eyelet out through the main incision to form the fish configuration. Similar to the fishtail technique, this insertion technique minimizes the risk for zonular damage or a capsule tear because the CTR is not dialed into the capsular bag. The advantage of the suture line is that it prevents over bending of the CTR during insertion through the main incision, which can occur using the traditional fishtail technique. Neither author has a financial or proprietary interest in any material or method mentioned. Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Matsunaga, Taichi; Yamashita, Jun K
2014-02-07
Specific gene knockout and rescue experiments are powerful tools in developmental and stem cell biology. Nevertheless, the experiments require multiple steps of molecular manipulation for gene knockout and subsequent rescue procedures. Here we report an efficient and single step strategy to generate gene knockout-rescue system in pluripotent stem cells by promoter insertion with CRISPR/Cas9 genome editing technology. We inserted a tetracycline-regulated inducible gene promoter (tet-OFF/TRE-CMV) upstream of the endogenous promoter region of vascular endothelial growth factor receptor 2 (VEGFR2/Flk1) gene, an essential gene for endothelial cell (EC) differentiation, in mouse embryonic stem cells (ESCs) with homologous recombination. Both homo- and hetero-inserted clones were efficiently obtained through a simple selection with a drug-resistant gene. The insertion of TRE-CMV promoter disrupted endogenous Flk1 expression, resulting in null mutation in homo-inserted clones. When the inserted TRE-CMV promoter was activated with doxycycline (Dox) depletion, Flk1 expression was sufficiently recovered from the downstream genomic Flk1 gene. Whereas EC differentiation was almost completely perturbed in homo-inserted clones, Flk1 rescue with TRE-CMV promoter activation restored EC appearance, indicating that phenotypic changes in EC differentiation can be successfully reproduced with this knockout-rescue system. Thus, this promoter insertion strategy with CRISPR/Cas9 would be a novel attractive method for knockout-rescue experiments. Copyright © 2014 Elsevier Inc. All rights reserved.
Hartmann, Xavier H M; van der Linde, Peter; Homburg, Erik F G A; van Breemen, Lambert C A; de Jong, Arthur M; Luttge, Regina
2015-11-18
Arrays of microneedles (MNAs) are integrated in an out-of-plane fashion with a base plate and can serve as patches for the release of drugs and vaccines. We used soft-lithography and micromolding to manufacture ceramic nanoporous (np)MNAs. Failure modes of ceramic npMNAs are as yet poorly understood and the question remained: is our npMNA platform technology ready for microneedle (MN) assembly into patches? We investigated npMNAs by microindentation, yielding average crack fracture forces above the required insertion force for a single MN to penetrate human skin. We further developed a thumb pressure-actuated applicator-assisted npMNA insertion method, which enables anchoring of MNs in the skin by an adhesive in one handling step. Using a set of simple artificial skin models, we found a puncture efficiency of this insertion method a factor three times higher than by applying thumb pressure on the npMNA base plate directly. In addition, this new method facilitated zero MN-breakage due to a well-defined force distribution exerted onto the MNs and the closely surrounding area prior to bringing the adhesive into contact with the skin. Owing to the fact that such parameter space exists, we can conclude that npMNAs by soft lithography are a platform technology for MN assembly into a patch.
Zhang, Lijing; Cao, Hua; Zhang, Jiaxin; Yang, Chengli; Hu, Tingting; Li, Huili; Yang, Wu; He, Gu; Song, Xiangrong; Tong, Aiping; Guo, Gang; Li, Rui; Jiang, Yu; Liu, Jiyan; Cai, Lulu; Zheng, Yu
2017-02-01
Specific delivery of drugs to bone tissue is very challenging due to the architecture and structure of bone tissue. A seven-repeat sequence of aspartate, a representative bone-targeting oligopeptide, is preferentially used for targeted therapy for bone diseases. In this study, Asp7-cholesterol((Asp)7-CHOL) was synthesized and (Asp)7-CHOL-modified liposome loaded with doxorubicin (DOX) was successfully prepared using both pre-insertion (pre-L) and post-insertion (post-L) methods. The formulation was optimized according to particle size, zeta potential and the drug-loading efficiency of the liposome. In addition, the bone affinity of the (Asp)7-CHOL-modified liposome was evaluated using a hydroxyapatite (HA) absorption method. The results suggested that (Asp)7-CHOL-modified liposome show excellent HA absorption; pre-L showed slightly higher HA binding than post-L. However, post-L had a higher DOX entrapment efficiency than pre-L. In vivo imaging further demonstrated that pre-L showed a higher bone-targeting efficiency than post-L, which was consistent with in vitro results. In all, (Asp)7-CHOL-modified liposome showed excellent bone-targeting activity, suggesting their potential for use as a drug delivery system for bone disease-targeted therapies.
Impact of Ultrasound on Short Peripheral Intravenous Catheter Placement on Vein Thrombosis Risk.
Holder, Max R; Stutzman, Sonja E; Olson, DaiWai M
Approximately 90% of hospitalized patients have a short peripheral intravenous catheter (SPC) placed. Methods of inserting the catheter have evolved over time and now include the use of ultrasound (US)-guided procedures for placement. Little is known about the impact that US-guided procedures have on the vein. This study compared the rate of venous thrombosis in patients with and without US-guided catheter placement. This prospective, single-blind, observational study assessed for venous thrombosis in 153 veins from 135 patients. Veins were evaluated by a research nurse blinded to the method of placement between 48 and 72 hours after the SPC was placed. The Fisher exact test showed a significant difference between vessel compressibility and catheter insertion method (P = .0012). The proportion of noncompressible veins was significantly greater when US was used in comparison with freehand SPC insertion. The Mantel-Haenszel chi-square value of 10.34 (P = .0013) showed that US insertion technique is associated with a higher likelihood of noncompressible veins. This pilot study provides compelling evidence that the use of US to assist with catheter placement is associated with a higher rate of noncompressible veins at day 2 or 3. Further studies are needed with a larger sample to determine the generalizability of the results from this pilot study.
Word and frame synchronization with verification for PPM optical communications
NASA Technical Reports Server (NTRS)
Marshall, William K.
1986-01-01
A method for obtaining word and frame synchronization in pulse position modulated optical communication systems is described. The method uses a short sync sequence inserted at the beginning of each data frame and a verification procedure to distinguish between inserted and randomly occurring sequences at the receiver. This results in an easy to implement sync system which provides reliable synchronization even at high symbol error rates. Results are given for the application of this approach to a highly energy efficient 256-ary PPM test system.
Using Comprehensive Video-Module Instruction as an Alternative Approach for Teaching IUD Insertion.
Garcia-Rodriguez, Juan Antonio; Donnon, Tyrone
2016-01-01
Family medicine clinicians and residents have increasing educational and work demands that have made it difficult to provide and access training on specific procedures such as IUD insertion. The purpose of this study was to determine whether the use of video-module instruction could provide residents with the necessary knowledge and skills to perform an IUD insertion correctly when compared with the traditional form of instruction, which is a lecture-demonstration session provided by an academic gynecologist. Thirty-nine family medicine residents participated in the study during the induction period at the beginning of their residency program in July 2012 at the University of Calgary. A randomized, two group pretest/posttest experimental research design was used to compare the procedural knowledge and skills performance (posttest only) of residents trained using an alternative instructional intervention (video-module teaching) with the traditional lecture-demonstration approach to teaching IUD insertion. Both teaching methods were effective in providing procedural knowledge instruction, and the paired-samples t tests results were almost identical: t (37)=1.35. On the other hand, performance scores were significantly higher in the video-module group: t (37)=2.37, 95% CI (0.61, 8.00), with a mean difference in performance of 4.31. There were no significant differences in residents' satisfaction scores, and there was no correlation between the different scores and sex or age or between performance and level of satisfaction. This video-module instruction is an effective method to provide comprehensive IUD insertion training, and the psychomotor skills gain (performance component) was significantly higher than the traditional method of instruction.
Seligmann, Hervé
2018-05-01
Genetic codes mainly evolve by reassigning punctuation codons, starts and stops. Previous analyses assuming that undefined amino acids translate stops showed greater divergence between nuclear and mitochondrial genetic codes. Here, three independent methods converge on which amino acids translated stops at split between nuclear and mitochondrial genetic codes: (a) alignment-free genetic code comparisons inserting different amino acids at stops; (b) alignment-based blast analyses of hypothetical peptides translated from non-coding mitochondrial sequences, inserting different amino acids at stops; (c) biases in amino acid insertions at stops in proteomic data. Hence short-term protein evolution models reconstruct long-term genetic code evolution. Mitochondria reassign stops to amino acids otherwise inserted at stops by codon-anticodon mismatches (near-cognate tRNAs). Hence dual function (translation termination and translation by codon-anticodon mismatch) precedes mitochondrial reassignments of stops to amino acids. Stop ambiguity increases coded information, compensates endocellular mitogenome reduction. Mitochondrial codon reassignments might prevent viral infections. Copyright © 2018 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Kim, Hyun-Sil; Kim, Jae-Seung; Lee, Seong-Hyun; Seo, Yun-Ho
2014-12-01
Insertion loss prediction of large acoustical enclosures using Statistical Energy Analysis (SEA) method is presented. The SEA model consists of three elements: sound field inside the enclosure, vibration energy of the enclosure panel, and sound field outside the enclosure. It is assumed that the space surrounding the enclosure is sufficiently large so that there is no energy flow from the outside to the wall panel or to air cavity inside the enclosure. The comparison of the predicted insertion loss to the measured data for typical large acoustical enclosures shows good agreements. It is found that if the critical frequency of the wall panel falls above the frequency region of interest, insertion loss is dominated by the sound transmission loss of the wall panel and averaged sound absorption coefficient inside the enclosure. However, if the critical frequency of the wall panel falls into the frequency region of interest, acoustic power from the sound radiation by the wall panel must be added to the acoustic power from transmission through the panel.
Insertion of Vertically Aligned Nanowires into Living Cells by Inkjet Printing of Cells.
Lee, Donggyu; Lee, Daehee; Won, Yulim; Hong, Hyeonaug; Kim, Yongjae; Song, Hyunwoo; Pyun, Jae-Chul; Cho, Yong Soo; Ryu, Wonhyoung; Moon, Jooho
2016-03-01
Effective insertion of vertically aligned nanowires (NWs) into cells is critical for bioelectrical and biochemical devices, biological delivery systems, and photosynthetic bioenergy harvesting. However, accurate insertion of NWs into living cells using scalable processes has not yet been achieved. Here, NWs are inserted into living Chlamydomonas reinhardtii cells (Chlamy cells) via inkjet printing of the Chlamy cells, representing a low-cost and large-scale method for inserting NWs into living cells. Jetting conditions and printable bioink composed of living Chlamy cells are optimized to achieve stable jetting and precise ink deposition of bioink for indentation of NWs into Chlamy cells. Fluorescence confocal microscopy is used to verify the viability of Chlamy cells after inkjet printing. Simple mechanical considerations of the cell membrane and droplet kinetics are developed to control the jetting force to allow penetration of the NWs into cells. The results suggest that inkjet printing is an effective, controllable tool for stable insertion of NWs into cells with economic and scale-related advantages. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Effectiveness of electrocardiographic guidance in CVAD tip placement.
Walker, Graham; Chan, Raymond J; Alexandrou, Evan; Webster, Joan; Rickard, Claire
International standard practice for the correct confirmation of the central venous access device is the chest X-ray. The intracavitary electrocardiogram-based insertion method is radiation-free, and allows real-time placement verification, providing immediate treatment and reduced requirement for post-procedural repositioning. Relevant databases were searched for prospective randomised controlled trials (RCTs) or quasi RCTs that compared the effectiveness of electrocardiogram-guided catheter tip positioning with placement using surface-anatomy-guided insertion plus chest X-ray confirmation. The primary outcome was accurate catheter tip placement. Secondary outcomes included complications, patient satisfaction and costs. Five studies involving 729 participants were included. Electrocardiogram-guided insertion was more accurate than surface anatomy guided insertion (odds ratio: 8.3; 95% confidence interval (CI) 1.38; 50.07; p=0.02). There was a lack of reporting on complications, patient satisfaction and costs. The evidence suggests that intracavitary electrocardiogram-based positioning is superior to surface-anatomy-guided positioning of central venous access devices, leading to significantly more successful placements. This technique could potentially remove the requirement for post-procedural chest X-ray, especially during peripherally inserted central catheter (PICC) line insertion.
In vivo blunt-end cloning through CRISPR/Cas9-facilitated non-homologous end-joining
Geisinger, Jonathan M.; Turan, Sören; Hernandez, Sophia; Spector, Laura P.; Calos, Michele P.
2016-01-01
The CRISPR/Cas9 system facilitates precise DNA modifications by generating RNA-guided blunt-ended double-strand breaks. We demonstrate that guide RNA pairs generate deletions that are repaired with a high level of precision by non-homologous end-joining in mammalian cells. We present a method called knock-in blunt ligation for exploiting these breaks to insert exogenous PCR-generated sequences in a homology-independent manner without loss of additional nucleotides. This method is useful for making precise additions to the genome such as insertions of marker gene cassettes or functional elements, without the need for homology arms. We successfully utilized this method in human and mouse cells to insert fluorescent protein cassettes into various loci, with efficiencies up to 36% in HEK293 cells without selection. We also created versions of Cas9 fused to the FKBP12-L106P destabilization domain in an effort to improve Cas9 performance. Our in vivo blunt-end cloning method and destabilization-domain-fused Cas9 variant increase the repertoire of precision genome engineering approaches. PMID:26762978
NASA Technical Reports Server (NTRS)
Klos, Jacob; Palumbo, Daniel L.
2003-01-01
A method to intended for measurement of the insertion loss of an acoustic treatment applied to an aircraft fuselage in-situ is documented in this paper. Using this method, the performance of a treatment applied to a limited portion of an aircraft fuselage can be assessed even though the untreated fuselage also radiates into the cabin, corrupting the intensity measurement. This corrupting noise in the intensity measurement incoherent with the panel vibration of interest is removed by correlating the intensity to reference transducers such as accelerometers. Insertion loss of the acoustic treatments is estimated from the ratio of correlated intensity measurements with and without a treatment applied. In the case of turbulent boundary layer excitation of the fuselage, this technique can be used to assess the performance of noise control methods without requiring treatment of the entire fuselage. Several experimental studies and numerical simulations have been conducted, and results from three case studies are documented in this paper. Conclusions are drawn about the use of this method to study aircraft sidewall treatments.
Tarity, T David; Koch, Chelsea N; Burket, Jayme C; Wright, Timothy M; Westrich, Geoffrey H
2017-03-01
Adverse local tissue reaction formation has been suggested to occur with the Modular Dual Mobility (MDM) acetabular design. Few reports in the literature have evaluated fretting and corrosion damage between the acetabular shell and modular metal inserts in this modular system. We evaluated a series of 18 retrieved cobalt chromium MDM inserts for evidence of fretting and corrosion. We assessed the backsides of 18 MDM components for evidence of fretting and corrosion in polar and taper regions based on previously established methods. We collected and assessed 30 similarly designed modular inserts retrieved from metal-on-metal (MoM) total hip arthroplasties as a control. No specific pattern of fretting or corrosion was identified on the MDM inserts. Both fretting and corrosion were significantly greater in the MoM cohort than the MDM cohort, driven by higher fretting and corrosion scores in the engaged taper region of the MoM inserts. MoM components demonstrated more fretting and corrosion than MDM designs, specifically at the taper region, likely driven by differences in the taper engagement mechanism and geometry among the insert designs. The lack of significant fretting and corrosion observed in the MDM inserts are inconsistent with recent claims that this interface may produce clinically significant metallosis and adverse local tissue reactions. Copyright © 2016 Elsevier Inc. All rights reserved.
Rao, Anand R; Engh, Gerard A; Collier, Matthew B; Lounici, Smain
2002-10-01
Wear occurring at the interface between the polyethylene insert and metal baseplate of a modular tibial component has become an increasingly common finding at the time of revision total knee arthroplasty. Although this so-called backside wear on retrieved polyethylene inserts has been evaluated in prior studies, wear on retrieved metal baseplates has not been described, to our knowledge. The purposes of the present study were to characterize backside wear on retrieved polyethylene inserts and on the mating surfaces of their corresponding baseplates and to investigate if there is a relationship between backside wear and relative motion of the modular elements. Twenty-nine retrieved modular tibial components of twelve fixed-bearing designs were analyzed in vitro with regard to backside wear and relative motion between the polyethylene insert and the metal baseplate. We graded the backside of each polyethylene insert and the mating surface of the metal baseplate for wear with use of a scoring system that consisted of three modes of wear and three levels of severity of wear. Relative motion between the insert and the baseplate was measured in the transverse plane with use of a mechanical testing machine. These measurements were used to compute the insert motion index, which served to quantify unrestricted motion of the insert with respect to the baseplate. The mean insert motion index for the tibial components was 416 micro m (range, 104 micro m to 760 micro m). On a wear-grading scale ranging from 0 to 54 (with 0 indicating no wear), the mean backside wear score was 30 (range, 12 to 48) for the inserts and 28 (range, 7 to 51) for the baseplates. Insert motion was positively correlated with backside polyethylene wear (p = 0.003) and baseplate wear (p < 0.001). Baseplate wear was strongly correlated with backside polyethylene wear (p < 0.001). Backside wear was correlated with the relative motion between the polyethylene insert and the metal baseplate. New locking mechanism designs directed toward better methods of securing the polyethylene insert to the tibial tray are needed to minimize the generation of particulate wear debris at the modular interface.
Patel, Paras R.; Na, Kyounghwan; Zhang, Huanan; Kozai, Takashi D. Y.; Kotov, Nicholas A.; Yoon, Euisik; Chestek, Cynthia A.
2016-01-01
Objective Single carbon fiber electrodes (d=8.4 μm) insulated with parylene-c and functionalized with PEDOT:pTS have been shown to record single unit activity but manual implantation of these devices with forceps can be difficult. Without an improvement in the insertion method any increase in the channel count by fabricating carbon fiber arrays would be impractical. In this study, we utilize a water soluble coating and structural backbones that allow us to create, implant, and record from fully functionalized arrays of carbon fibers with ~150 μm pitch. Approach Two approaches were tested for the insertion of carbon fiber arrays. The first method used a PEG coating that temporarily stiffened the fibers while leaving a small portion at the tip exposed. The small exposed portion (500 μm – 1 mm) readily penetrated the brain allowing for an insertion that did not require the handling of each fiber by forceps. The second method involved the fabrication of silicon support structures with individual shanks spaced 150 μm apart. Each shank consisted of a small groove that held an individual carbon fiber. Main results Our results showed that the PEG coating allowed for the chronic implantation of carbon fiber arrays in 5 rats with unit activity detected at 31 days post-implant. The silicon support structures recorded single unit activity in 3 acute rat surgeries. In one of those surgeries a stacked device with 3 layers of silicon support structures and carbon fibers was built and shown to readily insert into the brain with unit activity on select sites. Significance From these studies we have found that carbon fibers spaced at ~150 μm readily insert into the brain. This greatly increases the recording density of chronic neural probes and paves the way for even higher density devices that have a minimal scarring response. PMID:26035638
Perez-Calatayud, Jose; Richart, Jose; Guirado, Damián; Pérez-García, Jordi; Rodríguez, Silvia; Santos, Manuel
2012-01-01
Purpose SeedSelectron® v1.26b (Nucletron BV, The Netherlands) is an afterloader system used in prostate interstitial permanent brachytherapy with I-125 selectSeed seeds. It contains a diode array to assay all implanted seeds. Only one or two seeds can be extracted during the surgical procedure and assayed using a well chamber to check the manufacturer air-kerma strength (SK) and to calibrate the diode array. Therefore, it is not feasible to assay 5–10% seeds as required by the AAPM-ESTRO. In this study, we present a practical solution of the SeedSelectron® users to fulfill the AAPM- ESTRO recommendations. Material and methods The method is based on: a) the SourceCheck® well ionization chamber (PTW, Germany) provided with a PTW insert; b) n = 10 selectSeed from the same batch and class as the seeds for the implant; c) the Nucletron insert to accommodate the n = 10 seeds on the SourceCheck® and to measure their averaged SK. Results for 56 implants have been studied comparing the SK value from the manufacturer with the one obtained with the n = 10 seeds using the Nucletron insert prior to the implant and with the SK of just one seed measured with the PTW insert during the implant. Results We are faced with SK deviation for individual seeds up to 7.8%. However, in the majority of cases SK is in agreement with the manufacturer value. With the method proposed using the Nucletron insert, the large deviations of SK are reduced and for 56 implants studied no deviation outside the range of the class were found. Conclusions The new Nucletron insert and the proposed procedure allow to evaluate the SK of the n = 10 seeds prior to the implant, fulfilling the AAPM-ESTRO recommendations. It has been adopted by Nucletron to be extended to seedSelectron® users under request. PMID:23346136
Mesarich, Carl H.; Rees-George, Jonathan; Gardner, Paul P.; Ghomi, Fatemeh Ashari; Gerth, Monica L.; Andersen, Mark T.; Rikkerink, Erik H. A.; Fineran, Peter C.
2017-01-01
Pseudomonas syringae pv. actinidiae (Psa), the causal agent of kiwifruit canker, is one of the most devastating plant diseases of recent times. We have generated two mini-Tn5-based random insertion libraries of Psa ICMP 18884. The first, a ‘phenotype of interest’ (POI) library, consists of 10,368 independent mutants gridded into 96-well plates. By replica plating onto selective media, the POI library was successfully screened for auxotrophic and motility mutants. Lipopolysaccharide (LPS) biosynthesis mutants with ‘Fuzzy-Spreader’-like morphologies were also identified through a visual screen. The second, a ‘mutant of interest’ (MOI) library, comprises around 96,000 independent mutants, also stored in 96-well plates, with approximately 200 individuals per well. The MOI library was sequenced on the Illumina MiSeq platform using Transposon-Directed Insertion site Sequencing (TraDIS) to map insertion sites onto the Psa genome. A grid-based PCR method was developed to recover individual mutants, and using this strategy, the MOI library was successfully screened for a putative LPS mutant not identified in the visual screen. The Psa chromosome and plasmid had 24,031 and 1,236 independent insertion events respectively, giving insertion frequencies of 3.65 and 16.6 per kb respectively. These data suggest that the MOI library is near saturation, with the theoretical probability of finding an insert in any one chromosomal gene estimated to be 97.5%. However, only 47% of chromosomal genes had insertions. This surprisingly low rate cannot be solely explained by the lack of insertions in essential genes, which would be expected to be around 5%. Strikingly, many accessory genes, including most of those encoding type III effectors, lacked insertions. In contrast, 94% of genes on the Psa plasmid had insertions, including for example, the type III effector HopAU1. These results suggest that some chromosomal sites are rendered inaccessible to transposon insertion, either by DNA-binding proteins or by the architecture of the nucleoid. PMID:28249011
Ninomiya, Koshi; Iwatsuki, Koichi; Ohnishi, Yu-Ichiro; Ohkawa, Toshika; Yoshimine, Toshiki
2016-10-01
Retrospective study. Cortical bone trajectory (CBT), a more medial-to-lateral and shorter path than the traditional one for spinal fusion, is thought to be effective for severely degenerated vertebrae because screws are primarily stabilized at the posterior elements. We evaluated the efficacy of this approach through in vivo insertional torque measurement. There has been only one prior in vivo study on CBT insertional torque. Between January 2013 and April 2014, a total of 22 patients underwent posterior lumbar fusion using the CBT technique. The maximum insertional torque, which covers the radial strength needed for insertion, was measured for 113 screws, 8 of which were inserted for L5 spondylolysis. The insertional torque for cases with (n=8) and without (n=31) spondylolysis of L5 were compared using one-way analysis of variance (ANOVA). To evaluate vertebral degeneration, we classified 53 vertebrae without spondylolysis by lumbar radiography using semiquantitative methods; the insertional torque for the 105 screws used was compared on the basis of this classification. Additionally, differences in insertional torque among cases grouped by age, sex, and lumbar level were evaluated for these 105 screws using ANOVA and the Tukey test. The mean insertional torque was significantly lower for patients with spondylolysis than for those without spondylolysis (4.25 vs. 8.24 in-lb). There were no statistical differences in insertional torque according to vertebral grading or level. The only significant difference in insertional torque between age and sex groups was in men <75 years and women ≥75 years (10 vs. 5.5 in-lb). Although CBT should be used with great caution in patient with lysis who are ≥75 years, it is well suited for dealing with severely degenerated vertebrae because the pars interarticularis plays a very important role in the implementation of this technique.
Method and apparatus for thermal processing of semiconductor substrates
Griffiths, Stewart K.; Nilson, Robert H.; Mattson, Brad S.; Savas, Stephen E.
2002-01-01
An improved apparatus and method for thermal processing of semiconductor wafers. The apparatus and method provide the temperature stability and uniformity of a conventional batch furnace as well as the processing speed and reduced time-at-temperature of a lamp-heated rapid thermal processor (RTP). Individual wafers are rapidly inserted into and withdrawn from a furnace cavity held at a nearly constant and isothermal temperature. The speeds of insertion and withdrawal are sufficiently large to limit thermal stresses and thereby reduce or prevent plastic deformation of the wafer as it enters and leaves the furnace. By processing the semiconductor wafer in a substantially isothermal cavity, the wafer temperature and spatial uniformity of the wafer temperature can be ensured by measuring and controlling only temperatures of the cavity walls. Further, peak power requirements are very small compared to lamp-heated RTPs because the cavity temperature is not cycled and the thermal mass of the cavity is relatively large. Increased speeds of insertion and/or removal may also be used with non-isothermal furnaces.
Method and apparatus for thermal processing of semiconductor substrates
Griffiths, Stewart K.; Nilson, Robert H.; Mattson, Brad S.; Savas, Stephen E.
2000-01-01
An improved apparatus and method for thermal processing of semiconductor wafers. The apparatus and method provide the temperature stability and uniformity of a conventional batch furnace as well as the processing speed and reduced time-at-temperature of a lamp-heated rapid thermal processor (RTP). Individual wafers are rapidly inserted into and withdrawn from a furnace cavity held at a nearly constant and isothermal temperature. The speeds of insertion and withdrawal are sufficiently large to limit thermal stresses and thereby reduce or prevent plastic deformation of the wafer as it enters and leaves the furnace. By processing the semiconductor wafer in a substantially isothermal cavity, the wafer temperature and spatial uniformity of the wafer temperature can be ensured by measuring and controlling only temperatures of the cavity walls. Further, peak power requirements are very small compared to lamp-heated RTPs because the cavity temperature is not cycled and the thermal mass of the cavity is relatively large. Increased speeds of insertion and/or removal may also be used with non-isothermal furnaces.
Combination therapy for male erectile dysfunction and urinary incontinence.
Zafirakis, Helen; Wang, Run; Westney, O Lenaine
2008-01-01
Urinary incontinence (UI) and erectile dysfunction (ED) are both very prevalent conditions. Insertion of an artificial urinary sphincter (AUS) and penile prosthesis (PP) is an effective and proven method of treatment for both conditions. With advancing age, as well as with increasing populations of patients radically treated for prostate cancer, the occurrence of both conditions found in the same patient is increasing. The purpose of this article was to analyze the available evidence for simultaneous surgical management of male ED and UI using prosthetic devices. The existing literature pertaining to dual implantation of AUS and PP was reviewed. The concomitant insertion of the PP with the male perineal sling was also considered. Concurrent ED and UI are increasingly seen in the post radical prostatectomy population, who are often younger and less willing to suffer with these conditions. Insertion of an AUS and PP, either simultaneously or as a two-stage procedure, appears to be a safe, efficacious and long-lasting method of treatment. The improvements in design of both the AUS and PP as well as the development of the single transverse scrotal incision have made simultaneous insertion of these prostheses possible. Dual implantation of the PP and male sling looks promising in a selected population. In conclusion, the insertion of the AUS and PP for the treatment of concurrent UI and ED is safe and effective. Simultaneous insertion of these prostheses in the same patient offers potential advantages in operative and recovery time and is associated with high patient satisfaction. Combination therapy should therefore be included in the arsenal of treatment of these conditions.
Intracochlear pressure transients during cochlear implant electrode insertion
Greene, Nathaniel T.; Mattingly, Jameson K.; Banakis Hartl, Renee M.; Tollin, Daniel J.; Cass, Stephen P.
2016-01-01
Hypothesis Cochlear implant (CI) electrode insertion into the round window induces pressure transients in the cochlear fluid comparable to high intensity sound transients. Background Many patients receiving a CI have some remaining functional hearing at low frequencies, thus devices and surgical techniques have been developed to utilize this residual hearing. To maintain functional acoustic hearing, it is important to retain function of any hair cells and auditory nerve fibers innervating the basilar membrane; however, in a subset of patients, residual low frequency hearing is lost following CI insertion. Here, we test the hypothesis that transient intracochlear pressure spikes are generated during CI electrode insertion, which could cause damage and compromise residual hearing. Methods Human cadaveric temporal bones were prepared with an extended facial recess. Pressures in the scala vestibuli (PSV) and tympani (PST) were measured with fiber-optic pressure sensors inserted into the cochlea near the oval and round windows while CI electrodes (five styles from two manufacturers) were inserted into the cochlea via a round window approach. Results PST tended to be larger in magnitude than PSV, consistent with electrode insertion into the scala tympani. CI electrode insertion produced a range of pressure transients in the cochlea that could occur alone or as part of a train of spikes with equivalent peak sound pressure levels in excess of 170dB SPL. Instances of pressure transients varied with electrode styles. Conclusions Results suggest electrode design, insertion mechanism, and surgical technique affect the magnitude and rate of intracochlear pressure transients during CI electrode insertion. Pressure transients showed intensities similar to those elicited by high level sounds and thus could cause damage to the basilar membrane and/or hair cells. PMID:27753703
Effect of Off-Axis Screw Insertion, Insertion Torque, and Plate Contouring on Locked Screw Strength
Gallagher, Bethany; Silva, Matthew J.; Ricci, William M.
2015-01-01
Objectives This study quantifies the effects of insertion torque, off-axis screw angulation, and plate contouring on the strength of locking plate constructs. Methods Groups of locking screws (n = 6–11 screws) were inserted at 50%, 100%, 150%, and 200% of the manufacturer-recommended torque (3.2 Nm) into locking compression plates at various angles: orthogonal (control), 5-degree angle off-axis, and 10-degree angle off-axis. Screws were loaded to failure by a transverse force (parallel to the plate) either in the same (“+”) or opposite direction (“−”) of the initial screw angulation. Separately, locking plates were bent to 5 and 10-degree angles, with the bend apex at a screw hole. Locking screws inserted orthogonally into the apex hole at 100% torque were loaded to failure. Results Orthogonal insertion resulted in the highest average load to failure, 2577 ± 141 N (range, 2413–2778 N), whereas any off-axis insertion significantly weakened constructs (165–1285 N, at 100% torque) (P < 0.05). For “+” loading, torque beyond 100% did not increase strength, but 50% torque reduced screw strength (P < 0.05). Loading in the “−” direction consistently resulted in higher strengths than “+” loading (P < 0.05). Plate contouring of 5-degree angle did not significantly change screw strength compared with straight plates but contouring of 10-degree angle significantly reduced load to failure (P < 0.05). Conclusions To maximize the screw plate interface strength, locking screws should be inserted without cross-threading. The mechanical stability of locked screws is significantly compromised by loose insertion, off-axis insertion, or severe distortion of the locking mechanism. PMID:24343255
Meirik, Olav; Brache, Vivian; Orawan, Kiriwat; Habib, Ndema Abu; Schmidt, Johannes; Ortayli, Nuriye; Culwell, Kelly; Jackson, Emily; Ali, Moazzam
2013-01-01
Comparative data on etonogestrel and two-rod levonorgestrel contraceptive implants are lacking. A multicenter, open, parallel-group trial with random allocation of implants was performed. For every second implant user, an age-matched woman choosing an intrauterine device (IUD) (TCu380A) was admitted. Methods and data on implant/IUD insertion and 6-week follow-up are reported. A total of 2008 women were randomized to an implant, and 974 women were enrolled in the IUD group. Results from 997 etonogestrel implant users, 997 levonorgestrel implant users and 971 IUD users were analyzed. In the etonogestrel and levonorgestrel groups, respectively, mean insertion durations were 51 (SD 50.2) s and 88 (SD 60.8) s; complication rates at insertion were 0.8% and 0.2%; and at follow-up, 27.2% and 26.7% of women, respectively, had signs or symptoms at the insertion site. At follow-up within 6 weeks after insertion, all implants were in situ, while 2.1% of IUDs were expelled. Performance of etonogestrel and levonorgestrel implants at insertion and within the first 6 weeks is similar. Short-term (6 weeks) continuation rates appear higher for implants than TCu380A. Copyright © 2013 Elsevier Inc. All rights reserved.
Surface Damage on Dental Implants with Release of Loose Particles after Insertion into Bone
Senna, Plinio; Del Bel Cury, Altair Antoninha; Kates, Stephen; Meirelles, Luiz
2015-01-01
Background Modern dental implants present surface features of distinct dimensions that can be damaged during the insertion procedure into bone. Purpose The aims of this study were (1) to quantify by means of roughness parameters the surface damage caused by the insertion procedure of dental implants and (2) to investigate the presence of loose particles at the interface. Materials and Methods Three groups of dental implants representing different surface topographies were inserted in fresh cow rib bone blocks. The surface roughness was characterized by interferometry on the same area before and after the insertion. SEM-BSD analysis was used to identify loose particles at the interface. Results The amplitude and hybrid roughness parameters of all three groups were lower after insertion. The surface presenting predominance of peaks (Ssk>0) associated to higher structures (height parameters) presented higher damage associated to more pronounced reduction of material volume. SEM-BSD images revealed loose titanium and aluminum particles at the interface mainly at the crestal cortical bone level. Conclusions Shearing forces during the insertion procedure alters the surface of dental implants. Loose metal particles can be generated at bone-implant interface especially around surfaces composed mainly by peaks and with increased height parameters. PMID:24283455
Evaluation of a high resolution silicon PET insert module
NASA Astrophysics Data System (ADS)
Grkovski, Milan; Brzezinski, Karol; Cindro, Vladimir; Clinthorne, Neal H.; Kagan, Harris; Lacasta, Carlos; Mikuž, Marko; Solaz, Carles; Studen, Andrej; Weilhammer, Peter; Žontar, Dejan
2015-07-01
Conventional PET systems can be augmented with additional detectors placed in close proximity of the region of interest. We developed a high resolution PET insert module to evaluate the added benefit of such a combination. The insert module consists of two back-to-back 1 mm thick silicon sensors, each segmented into 1040 1 mm2 pads arranged in a 40 by 26 array. A set of 16 VATAGP7.1 ASICs and a custom assembled data acquisition board were used to read out the signal from the insert module. Data were acquired in slice (2D) geometry with a Jaszczak phantom (rod diameters of 1.2-4.8 mm) filled with 18F-FDG and the images were reconstructed with ML-EM method. Both data with full and limited angular coverage from the insert module were considered and three types of coincidence events were combined. The ratio of high-resolution data that substantially improves quality of the reconstructed image for the region near the surface of the insert module was estimated to be about 4%. Results from our previous studies suggest that such ratio could be achieved at a moderate technological expense by using an equivalent of two insert modules (an effective sensor thickness of 4 mm).
Insertion and deletion mutagenesis of the human cytomegalovirus genome
DOE Office of Scientific and Technical Information (OSTI.GOV)
Spaete, R.R.; Mocarski, E.S.
1987-10-01
Studies on human cytomegalovirus (CMV) have been limited by a paucity of molecular genetic techniques available for manipulating the viral genome. The authors have developed methods for site-specific insertion and deletion mutagenesis of CMV utilizing a modified Escherichia coli lacZ gene as a genetic marker. The lacZ gene was placed under the control of the major ..beta.. gene regulatory signals and inserted into the viral genome by homologous recombination, disrupting one of two copies of this ..beta.. gene within the L-component repeats of CMV DNA. They observed high-level expression of ..beta..-galactosidase by the recombinant in a temporally authentic manner, withmore » levels of this enzyme approaching 1% of total protein in infected cells. Thus, CMV is an efficient vector for high-level expression of foreign gene products in human cells. Using back selection of lacZ-deficient virus in the presence of the chromogenic substrate 5-bromo-4-chloro-3-indolyl ..beta..-D-galactoside, they generated random endpoint deletion mutants. Analysis of these mutant revealed that CMV DNA sequences flanking the insert had been removed, thereby establishing this approach as a means of determining whether sequences flanking a lacZ insertion are dispensable for viral growth. In an initial test of the methods, they have shown that 7800 base pairs of one copy of L-component repeat sequences can be deleted without affecting viral growth in human fibroblasts.« less
Clinical effectiveness of lidocaine and benzocaine for topical anesthesia.
Rosa, A. L.; Sverzut, C. E.; Xavier, S. P.; Lavrador, M. A.
1999-01-01
The effectiveness of lidocaine and benzocaine in reducing pain produced by needle insertion into the palate was evaluated in a double-blind and placebo-controlled study using a more suitable method. Twenty subjects, 10 men and 10 women, submitted to 4 sessions in which they were randomly treated with 5% lidocaine, a placebo that tasted like lidocaine, 20% benzocaine, and a placebo that tasted like benzocaine. At each session, a 27-gauge needle was inserted into the palate twice, once before (baseline) and once after drug application for 1 minute. Immediately after each insertion, subjects indicated on a visual analog scale the pain intensity perceived. Lidocaine and benzocaine were equally efficient, and both were better than placebo in reducing pain caused by insertion of needles into the palate. PMID:11692349
Obstruction after Self-expanding Metallic Stents in Tuberculous Bronchial Stenosis
Kim, Won; Lee, Youg Chul; Rhee, Yang Keun
1995-01-01
Expandable metallic stents seemed to be a good method in tuberculous bronchial stenosis that does not respond to medical therapy. But there was no long-term follow-up study after stents insertion in tuberculous bronchial stenosis. We report a case of obstruction after successful Gianturco metallic stents insertion due to tuberculous bronchial stenosis. PMID:7542914
Jang, Hui Won; Kim, Yoon Nam; Nam, Chung Mo; Lee, Hyun Jung; Park, Soo Jung; Hong, Sung Pil; Kim, Tae Il; Kim, Won Ho; Cheon, Jae Hee
2012-12-01
We examined whether the insertion time for colonoscopies performed after left-sided resection was different in patients with a colostomy from that in patients without a colostomy and identified factors that could impact colonoscopy performance. We included consecutive patients who underwent colonoscopy between July 2005 and March 2011 after left-sided colorectal resection for colorectal cancer. We classified surgical methods according to the presence or absence of a colostomy and evaluated colonoscope insertion time retrospectively. Furthermore, we analyzed factors that might affect insertion time. A total of 1,041 patients underwent colonoscopy after left-sided colorectal resection during the study period. The colonoscopy completion rate was 98.6 %, and the mean insertion time was 6.1 ± 4.6 min (median 4.7 min, range 0.3-35.8 min). A shorter resection length of colon, the presence of a colostomy, and a lower endoscopist case volume were found to be independent factors associated with prolonged insertion time in patients with left-sided colorectal resection. Among experienced colonoscopists, no colonoscopy-associated or clinical factors were found to affect insertion time. However, a shorter resection length of colon, the presence of a colostomy, and poor bowel preparation were associated with prolonged insertion time among inexperienced endoscopists. We identified three factors that affect colonoscope insertion time after left-sided colorectal resection, including the presence of a colostomy. Inexperienced endoscopists were much more affected by the presence of a colostomy after left-sided colorectal resection. These findings have implications for the practice and teaching of colonoscopy after left-sided colorectal resection.
Forgie, Marie M; Greer, Danielle M; Kram, Jessica J F; Vander Wyst, Kiley B; Salvo, Nicole P; Siddiqui, Danish S
2016-03-01
Foley catheters are used for cervical ripening during induction of labor. Previous studies suggest that use of a stylette (a thin, rigid wire) to guide catheter insertion decreases insertion failure. However, stylette effects on insertion outcomes have been sparsely studied. The purpose of this study was to compare catheter insertion times, patient-assessed pain levels, and insertion failure rates between women who received a digitally placed Foley catheter for cervical ripening with the aid of a stylette and women who received the catheter without a stylette. We conducted a randomized clinical trial of women aged ≥ 18 years who presented for induction of labor. Inclusion criteria were singletons with intact membranes and cephalic presentation. Women received a computer-generated random assignment of a Foley catheter insertion with a stylette (treatment group, n = 62) or without a stylette (control group, n = 61). For all women, a standard insertion technique protocol was used. Three primary outcomes were of interest, including the following: (1) insertion time (total minutes to successful catheter placement), (2) patient-assessed pain level (0-10), and (3) failure rate of the randomly assigned insertion method. Treatment control differences were first examined using the Pearson's test of independence and the Student t test. Per outcome, we also constructed 4 regression models, each including the random effect of physician and fixed effects of stylette use with patient nulliparity, a history of vaginal delivery, cervical dilation at presentation, or postgraduate year of the performing resident physician. Women who received the Foley catheter with the stylette vs without the stylette did not differ by age, race/ethnicity, body mass index, or any of several other characteristics. Regression models revealed that insertion time, patient pain, and insertion failure were unrelated to stylette use, nulliparity, and history of vaginal delivery. However, overall insertion time and failure were significantly influenced by cervical dilation, with insertion time decreasing by 21% (95% confidence interval [CI], 5-34%) and odds of failure decreasing by 71% (odds ratio, 0.29; 95% CI, 0.10-0.86) per 1 cm dilation. Resident postgraduate year also significantly influenced insertion time, with greater time required of physicians with less experience. Mean insertion time was 51% (95% CI, 23-69%) shorter for fourth-year than second-year residents. Statistically nonsignificant but prominent patterns in outcomes were also observed, suggesting stylette use may lengthen the overall insertion procedure but minimize variability in pain levels and decrease insertion failure. The randomized trial suggests that, even after accounting for nulliparity, history of vaginal delivery, cervical dilation, and physician experience, Foley catheter insertions with and without a stylette are equivalent in insertion times, patient pain levels, and failure of catheter placement. Copyright © 2016 Elsevier Inc. All rights reserved.
Peritoneal Dialysis Catheter Insertion.
Crabtree, John H; Chow, Kai-Ming
2017-01-01
The success of peritoneal dialysis as renal-replacement therapy depends on a well-functioning peritoneal catheter. Knowledge of best practices in catheter insertion can minimize the risk of catheter complications that lead to peritoneal dialysis failure. The catheter placement procedure begins with preoperative assessment of the patient to determine the most appropriate catheter type, insertion site, and exit site location. Preoperative preparation of the patient is an instrumental step in facilitating the performance of the procedure, avoiding untoward events, and promoting the desired outcome. Catheter insertion methods include percutaneous needle-guidewire with or without image guidance, open surgical dissection, peritoneoscopic procedure, and surgical laparoscopy. The insertion technique used often depends on the geographic availability of material resources and local provider expertise in placing catheters. Independent of the catheter implantation approach, adherence to a number of universal details is required to ensure the best opportunity for creating a successful long-term peritoneal access. Finally, appropriate postoperative care and catheter break-in enables a smooth transition to dialysis therapy. Copyright © 2017 Elsevier Inc. All rights reserved.
Sultan, Torky; Khedr, Ayman E; Sayed, Mostafa
2013-01-01
NONE DECLARED Defect tracking systems play an important role in the software development organizations as they can store historical information about defects. There are many research in defect tracking models and systems to enhance their capabilities to be more specifically tracking, and were adopted with new technology. Furthermore, there are different studies in classifying bugs in a step by step method to have clear perception and applicable method in detecting such bugs. This paper shows a new proposed defect tracking model for the purpose of classifying the inserted defects reports in a step by step method for more enhancement of the software quality.
Measurement of food texture by an acoustic vibration method
NASA Astrophysics Data System (ADS)
Sakurai, Naoki; Taniwaki, Mitsuru; Iwatani, Shin-ichiro; Akimoto, Hidemi
2011-09-01
Food texture was measured by a new acoustic vibration method. A piezoelectric sensor sandwiched between a probe and piston was inserted into a food sample by delivery of silicon oil to a cylinder by a pump. Vibration emitted from the food sample on insertion of the probe was monitored by voltage outputs of the sensor. The voltage signals were passed through 19 half octave bands to calculate texture index for each band. The texture index was defined as vibration energy of the probe caused by the food rupture and/or breakage per unit time.
Method of using infrared radiation for assembling a first component with a second component
Sikka, Vinod K.; Whitson, Barry G.; Blue, Craig A.
1999-01-01
A method of assembling a first component for assembly with a second component involves a heating device which includes an enclosure having a cavity for inserting a first component. An array of infrared energy generators is disposed within the enclosure. At least a portion of the first component is inserted into the cavity, exposed to infrared energy and thereby heated to a temperature wherein the portion of the first component is sufficiently softened and/or expanded for assembly with a second component.
Hubbell, Joel M.; Sisson, James B.
2005-07-26
A method of inserting a tensiometer into a sample, comprises providing a drive probe configured to be engaged by direct push equipment; supporting a porous member from the drive probe; and driving the drive probe into the sample using a cone penetrometer. A tensiometer comprises a drive probe configured to be engaged by direct push equipment or a cone penetrometer; a porous member supported by the drive probe; and a pressure sensor in pressure sensing relation to the porous member.
Sonoembryological evaluations of the development of placenta previa and velamentous cord insertion.
Hasegawa, Junichi
2015-01-01
Longitudinal and cross-sectional investigations using ultrasound examinations during pregnancy can be used to clarify the mechanisms and pathophysiology of abnormal fetal and placental development. Such sonoembryological assessments are useful as a method for clarifying the etiology of disease. In the present review, we describe current knowledge based on our experience with applying sonoembryological methods to determine the developmental mechanisms of placenta previa and velamentous cord insertion. © 2014 The Author. Journal of Obstetrics and Gynaecology Research © 2014 Japan Society of Obstetrics and Gynecology.
Systems and methods for processing irradiation targets through a nuclear reactor
Dayal, Yogeshwar; Saito, Earl F.; Berger, John F.; Brittingham, Martin W.; Morales, Stephen K.; Hare, Jeffrey M.
2016-05-03
Apparatuses and methods produce radioisotopes in instrumentation tubes of operating commercial nuclear reactors. Irradiation targets may be inserted and removed from instrumentation tubes during operation and converted to radioisotopes otherwise unavailable during operation of commercial nuclear reactors. Example apparatuses may continuously insert, remove, and store irradiation targets to be converted to useable radioisotopes or other desired materials at several different origin and termination points accessible outside an access barrier such as a containment building, drywell wall, or other access restriction preventing access to instrumentation tubes during operation of the nuclear plant.
Rajic, Slobodan; Muhs, Jeffrey D.
1996-01-01
A fiber optic connector and method for connecting composite materials within which optical fibers are imbedded. The fiber optic connector includes a capillary tube for receiving optical fibers at opposing ends. The method involves inserting a first optical fiber into the capillary tube and imbedding the unit in the end of a softened composite material. The capillary tube is injected with a coupling medium which subsequently solidifies. The composite material is machined to a desired configuration. An external optical fiber is then inserted into the capillary tube after fluidizing the coupling medium, whereby the optical fibers are coupled.
Schödel, Petra; Proescholdt, Martin; Brawanski, Alexander; Bele, Sylvia; Schebesch, Karl-Michael
2012-04-01
Burr-hole trephine and insertion of an external ventricular drainage (EVD) is a common procedure in neurosurgical practice. In critically ill patients, the transport to the operating room, OR represents a major risk. Thus, the burr-hole trephine and implantation of an EVD is frequently performed on the Intensive Care Unit (ICU). Since 2004, we have applied two different procedures: the conventional method with a mechanical compressed air or an electric drill, and an alternative method with a manual twist drill, including fixation of the EVD in a skull screw (Bolt Kit, Raumedic AG, Germany). This study was designed to evaluate the outcome of both surgical procedures. In this retrospective analysis we included 166 consecutive patients with acute hydrocephalus due to intracranial hemorrhage that had been operated at our neurosurgical ICU in a six years interval. We reviewed the charts for gender and age, kind of surgical procedure, cerebrospinal fluid (CSF)-infections, duration of drainage, attempts of insertions, wound infections, misplacement rate, post-surgical hemorrhages, revisions, comorbidities and shunt-dependency. In 122 patients we applied the Bolt Kit System, in 44 patients the conventional method was performed. We found a significantly lower rate of CSF-infections and significantly fewer attempts of insertions in the Bolt Kit group (p = 0.002 and p = 0.001, respectively). The rate of wound infections, misplacement, revisions, shunt-dependency and the post-surgical hemorrhages did not differ significantly. Our data indicate that the manual drill and the skull screw are safe and feasible tools in the treatment of acute hydrocephalus. Presumably, the direct skin contact is causative for the higher rate of CSF-infections when the conventional method is performed. The skull screw guides the EVD into the ventricle without skin contact. The lower number of insertions needed may be due to the fact that the skull screw allows just one trajectory for the insertion of the EVD.
Carr, Peter J; Rippey, James C R; Cooke, Marie L; Bharat, Chrianna; Murray, Kevin; Higgins, Niall S; Foale, Aileen; Rickard, Claire M
2016-01-01
Introduction Peripheral intravenous cannula (PIVC) insertion is one of the most common clinical interventions performed in emergency care worldwide. However, factors associated with successful PIVC placement and maintenance are not well understood. This study seeks to determine the predictors of first time PIVC insertion success in emergency department (ED) and identify the rationale for removal of the ED inserted PIVC in patients admitted to the hospital ward. Reducing failed insertion attempts and improving peripheral intravenous cannulation practice could lead to better staff and patient experiences, as well as improving hospital efficiency. Methods and analysis We propose an observational cohort study of PIVC insertions in a patient population presenting to ED, with follow-up observation of the PIVC in subsequent admissions to the hospital ward. We will collect specific PIVC observational data such as; clinician factors, patient factors, device information and clinical practice variables. Trained researchers will gather ED PIVC insertion data to identify predictors of insertion success. In those admitted from the ED, we will determine the dwell time of the ED-inserted PIVC. Multivariate regression analyses will be used to identify factors associated with insertions success and PIVC failure and standard statistical validation techniques will be used to create and assess the effectiveness of a clinical predication rule. Ethics and dissemination The findings of our study will provide new evidence to improve insertion success rates in the ED setting and identify strategies to reduce premature device failure for patients admitted to hospital wards. Results will unravel a complexity of factors that contribute to unsuccessful PIVC attempts such as patient and clinician factors along with the products, technologies and infusates used. Trial registration number ACTRN12615000588594; Pre-results. PMID:26868942
Munteanu, O; Radulescu, L; Bodean, O; Cirstoiu, C; Secara, D; Cirstoiu, M
2013-01-01
Abstract Objective: This study was undertaken in order to determine if antibiotic prophylaxis is mandatory, after the insertion of levonorgestrel-releasing intrauterine system in order to decrease the risk of pelvic inflammatory disease. Materials and methods: We prospectively evaluated 44 patients, admitted in the Bucharest Emergency Hospital between the 1ⁱ of February 2012 and the 1ⁱ of October 2012, in whom the levonorgestrel-releasing intrauterine system was inserted. The patients enrolled were divided into two groups. In group A, a number of 22 patients, received, after the insertion of levonorgestrel-releasing intrauterine system, 875mg Amoxicillin Trihydrate + 125 mg Potassium Clavulanate, a dose every 12 hours for 5 days. Group B was represented by the other 22 patients who did not receive antibiotic prophylaxis. All patients were reevaluated at 4 and 12 weeks after the insertion of levonorgestrel-releasing intrauterine system. Results: During the first 4 weeks after the insertion of levonorgestrel-releasing intrauterine system only two patients, one from group A and one from group B were diagnosed with pelvic inflammatory disease. At a second follow up visit – 12 weeks after the insertion of levonorgestrel-releasing intrauterine system, no other patient was diagnosed with pelvic inflammatory disease. Conclusion: Antibiotic prophylaxis is not mandatory, after the insertion of levonorgestrel-releasing intrauterine system in order to decrease the risk of pelvic inflammatory disease. PMID:24868262
Schmidt, Nathan W.; Grigoryan, Gevorg
2017-01-01
Abstract Coiled‐coils are essential components of many protein complexes. First discovered in structural proteins such as keratins, they have since been found to figure largely in the assembly and dynamics required for diverse functions, including membrane fusion, signal transduction and motors. Coiled‐coils have a characteristic repeating seven‐residue geometric and sequence motif, which is sometimes interrupted by the insertion of one or more residues. Such insertions are often highly conserved and critical to interdomain communication in signaling proteins such as bacterial histidine kinases. Here we develop the “accommodation index” as a parameter that allows automatic detection and classification of insertions based on the three dimensional structure of a protein. This method allows precise identification of the type of insertion and the “accommodation length” over which the insertion is structurally accommodated. A simple theory is presented that predicts the structural perturbations of 1, 3, 4 residue insertions as a function of the length over which the insertion is accommodated. Analysis of experimental structures is in good agreement with theory, and shows that short accommodation lengths give rise to greater perturbation of helix packing angles, changes in local helical phase, and increased structural asymmetry relative to long accommodation lengths. Cytoplasmic domains of histidine kinases in different signaling states display large changes in their accommodation lengths, which can now be seen to underlie diverse structural transitions including symmetry/asymmetry and local variations in helical phase that accompany signal transduction. PMID:27977891
Deficiencies of product labeling directions for the preparation of radiopharmaceuticals.
Hung, Joseph C; Ponto, James A; Gadient, Katie R; Frie, Julia A; Aksamit, Carolyn M; Enquist, Cassandra L; Carrels, Katie E
2004-01-01
To identify potential deficiencies in product labeling (package insert) instructions for the preparation of radiopharmaceuticals. Preparation instructions, which include both reconstitution and quality control (QC) directions, as stated in the package inserts were evaluated for all commercially available reconstituted radiopharmaceuticals. Reviews of the package inserts were initially performed by each author, and then all identified deficiencies were compiled and evaluated by all authors. The preparation scenario for each package insert evaluated was based on a centralized nuclear pharmacy operation assuming typical support personnel, standard operating equipment, and workload. The instructions as stated in each package insert for the preparation (including QC) were rated as inadequate if a satisfactory preparation could not be prepared by a nuclear pharmacist or physician when instructions were followed exactly. Identified deficiencies in package insert instructions for the preparation of radiopharmaceuticals fell into the following five categories: (1) absent or incomplete directions (especially with regard to QC procedures); (2) restrictive directions (e.g., specific requirement to use designated needles, chromatography solvents, counting devices), (3) inconsistent directions (e.g., different reconstituted volumes for the same final drug product, unworkable expiration times); (4) impractical directions (e.g., unrealistically low reconstituted activity limits, dangerously high number of radiolabeled particles); and (5) vague directions (e.g., use of the words "should," "may," "recommend"). Manufacturers' directions for the preparation of radiopharmaceuticals often contain deficiencies and should be viewed as standard guidance rather than as requirements. Just as physicians are permitted to use U.S. Food and Drug Administration (FDA)-approved drugs for off-label indications, nuclear pharmacists should be allowed to use alternative methods for preparing radiopharmaceuticals, provided those methods have been validated to be as good as the stated directions and that the nuclear pharmacists do not engage in activities that fall outside the normal practice of pharmacy. Manufacturers, FDA, nuclear pharmacists, and nuclear physicians should work together to address identified deficiencies in package insert directions.
Degidi, Marco; Daprile, Giuseppe; Piattelli, Adriano
The aims of this study were to evaluate the ability of a stepped osteotomy to improve dental implant primary stability in low-density bone sites and to investigate possible correlations between primary stability parameters. The study was performed on fresh humid bovine bone classified as type III. The test group consisted of 30 Astra Tech EV implants inserted following the protocol provided by the manufacturer. The first control group consisted of 30 Astra Tech EV implants inserted in sites without the underpreparation of the apical portion. The second control group consisted of 30 Astra Tech TX implants inserted following the protocol provided by the manufacturer. Implant insertion was performed at the predetermined 30 rpm. The insertion torque data were recorded and exported as a curve; using a trapezoidal integration technique, the area underlying the curve was calculated: this area represents the variable torque work (VTW). Peak insertion torque (pIT) and resonance frequency analysis (RFA) were also recorded. A Mann-Whitney test showed that the mean VTW was significantly higher in the test group compared with the first control and second control groups; furthermore, statistical analysis showed that pIT also was significantly higher in the test group compared with the first and second control groups. Analyzing RFA values, only the difference between the test group and second control group showed statistical significance. Pearson correlation analysis showed a very strong positive correlation between pIT and VTW values in all groups; furthermore, it showed a positive correlation between pIT and RFA values and between VTW and RFA values only in the test group. Within the limitations of an in vitro study, the results show that stepped osteotomy can be a viable method to improve implant primary stability in low-density bone sites, and that, when a traditional osteotomy method is performed, RFA presents no correlation with pIT and VTW.
Perl, Jeffrey; Pierratos, Andreas; Kandasamy, Gokulan; McCormick, Brendan B; Quinn, Robert R; Jain, Arsh K; Huang, Anjie; Paterson, J Michael; Oliver, Matthew J
2015-02-01
The likelihood of peritoneal dialysis (PD) utilization following a PD catheter insertion attempt is poorly described. We explored the risk factors for PD nonuse, focusing on the method of PD catheter implantation. This population-based retrospective cohort study employed Ontario administrative health data to identify 3886 predialysis adults who had an incident PD catheter implantation between 2002 and 2010. The impact of the method of catheter implantation including open-surgical (open, n = 1884), surgical-laparoscopic (laparoscopic, n = 1154), nephrology-percutaneous (nephrology, n = 498) and radiology-percutaneous (radiology, n = 350) on rates of PD utilization (defined as four consecutive weeks of PD) was examined. Eighty-three percent of study patients received PD. After adjustment, relative to patients with openly inserted catheters, PD utilization was greater for those with nephrology-inserted catheters [adjusted hazard ratio (aHR) 1.59, 95% confidence interval (CI) 1.29-1.95] and similar for radiology-inserted catheters [aHR 1.16, 95% CI 0.94-1.43] or laparoscopic-inserted catheters [aHR 0.97 (95% CI 0.86-1.09)]. Among PD nonusers, death occurred in 10% of the open group, 6% of the laparoscopic group, 27% of the radiology group and in fewer than 3% of the nephrology group. Sixty-nine percent received hemodialysis in the open group, 63% in the laparoscopic group, 61% in the radiology group and 88% in the nephrology group. Those remaining predialysis comprised 12% of the open group, 22% of the laparoscopic group, 11% of the radiology group and <3% of the nephrology group. Nephrology insertion resulted in lower overall rates of PD nonuse, particularly due to death or remaining predialysis. Greater use may be related to insertion timing, technique or greater commitment on the part of nephrologists to the success of PD. © The Author 2014. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved.
Dynamic soft tissue deformation estimation based on energy analysis
NASA Astrophysics Data System (ADS)
Gao, Dedong; Lei, Yong; Yao, Bin
2016-10-01
The needle placement accuracy of millimeters is required in many needle-based surgeries. The tissue deformation, especially that occurring on the surface of organ tissue, affects the needle-targeting accuracy of both manual and robotic needle insertions. It is necessary to understand the mechanism of tissue deformation during needle insertion into soft tissue. In this paper, soft tissue surface deformation is investigated on the basis of continuum mechanics, where a geometry model is presented to quantitatively approximate the volume of tissue deformation. The energy-based method is presented to the dynamic process of needle insertion into soft tissue based on continuum mechanics, and the volume of the cone is exploited to quantitatively approximate the deformation on the surface of soft tissue. The external work is converted into potential, kinetic, dissipated, and strain energies during the dynamic rigid needle-tissue interactive process. The needle insertion experimental setup, consisting of a linear actuator, force sensor, needle, tissue container, and a light, is constructed while an image-based method for measuring the depth and radius of the soft tissue surface deformations is introduced to obtain the experimental data. The relationship between the changed volume of tissue deformation and the insertion parameters is created based on the law of conservation of energy, with the volume of tissue deformation having been obtained using image-based measurements. The experiments are performed on phantom specimens, and an energy-based analytical fitted model is presented to estimate the volume of tissue deformation. The experimental results show that the energy-based analytical fitted model can predict the volume of soft tissue deformation, and the root mean squared errors of the fitting model and experimental data are 0.61 and 0.25 at the velocities 2.50 mm/s and 5.00 mm/s. The estimating parameters of the soft tissue surface deformations are proven to be useful for compensating the needle-targeting error in the rigid needle insertion procedure, especially for percutaneous needle insertion into organs.
The Influence of Tactile Perception on Classification of Bone Tissue at Dental Implant Insertion.
Linck, Gláucia Kelly Silva Barbosa; Ferreira, Geovane Miranda; De Oliveira, Rubelisa Cândido Gomes; Lindh, Christina; Leles, Cláudio Rodrigues; Ribeiro-Rotta, Rejane Faria
2016-06-01
Various ways of using the Lekholm and Zarb (L&Z) classification have added to the lack of scientific evidence of the effectiveness of this clinical method in the evaluation of implant treatment. The study aims to assess subjective jawbone classifications in patients referred for implant treatment, using L&Z classification with and without surgeon's hand perception at implant insertion. The association between bone type classifications and quantitative parameters of primary implant stability was also assessed. One hundred thirty-five implants were inserted using conventional loading protocol. Three surgeons classified bone quality at implant sites using two methods: one based on periapical and panoramic images (modified L&Z) and one based on the same images associated with the surgeon's tactile perception during drilling (original L&Z). Peak insertion torque and implant stability quotient (ISQ) were recorded. The modified and original L&Z were strongly correlated (rho = 0.79; p < .001); Wilcoxon signed-rank test showed no significant difference in the distribution of bone type classification between pairs using the two methods (p = .538). Spearman correlation tested the association between primary stability parameters and bone type classifications (-0.34 to -0.57 [p < .001]). Tactile surgical perception has a minor influence on rating of subjective bone type for dental implant treatment using the L&Z classification. © 2015 Wiley Periodicals, Inc.
Repairing Fractured Bones by Use of Bioabsorbable Composites
NASA Technical Reports Server (NTRS)
Farley, Gary L.
2006-01-01
A proposed method of surgical repair of fractured bones would incorporate recent and future advances in the art of composite materials. The composite materials used in this method would be biocompatible and at least partly bioabsorbable: that is, during the healing process following surgery, they would be wholly or at least partly absorbed into the bones and other tissues in which they were implanted. Relative to the traditional method, the proposed method would involve less surgery, pose less of a risk of infection, provide for better transfer of loads across fracture sites, and thereby promote better healing while reducing the need for immobilization by casts and other external devices. One requirement that both the traditional and proposed methods must satisfy is to fix the multiple segments of a broken bone in the correct relative positions. Mechanical fixing techniques used in the traditional method include the use of plates spanning the fracture site and secured to the bone by screws, serving of wire along the bone across the fracture site, insertion of metallic intramedullary rods through the hollow portion of the fractured bone, and/or inserting transverse rods through the bone, muscle, and skin to stabilize the fractured members. After the bone heals, a second surgical operation is needed to remove the mechanical fixture(s). In the proposed method, there would be no need for a second surgical operation. The proposed method is based partly on the observation that in the fabrication of a structural member, it is generally more efficient and reliable to use multiple small fasteners to transfer load across a joint than to use a single or smaller number of larger fasteners, provided that the stress fields of neighboring small fasteners do not overlap or interact. Also, multiple smaller fasteners are more reliable than are larger and fewer fasteners. However, there is a trade-off between structural efficiency and the cost of insertion time and materials. The proposed method is further based partly on the conjecture that through-the-thickness reinforcements could be excellent for fixing bone segments for surgical repair. The through-the-thickness reinforcements would superficially resemble nails in both form and function. Denoted small-diameter rods (SDRs) to distinguish them from other narrow rods, these reinforcements would be shot or otherwise inserted through adjacent segments of fractured bone to fix them in their correct relative positions (see figure). Shot insertion would be effected by use an applicator that would amount to a miniaturized and highly refined version of the pneumatic guns often used in carpentry to drive nails and brads. The applicator, envisioned to be about the size of a ball-point-pen, would be driven by pressurized carbon dioxide. To further promote stabilization of the segments, layers of bone glue could be applied to the fracture surfaces prior to insertion of the SDRs. The bone glue could be therapeutically loaded with chemicals to promote growth of bone and fight infection
Method of fabricating a honeycomb structure
Holleran, Louis M.; Lipp, G. Daniel
1999-01-01
A method of fabricating a monolithic honeycomb structure product involves shaping a first mixture of raw materials and a binder into a green honeycomb, extruding a second mixture of raw materials and a binder into one or more green members that each define an opening extending longitudinally therethrough. The raw materials of the second mixture are compatible with the raw materials of the first mixture. The green honeycomb and member(s) are dried. The binders of the green honeycomb and member(s) are softened at the surfaces that are to be bonded. The green member(s) is inserted into the honeycomb and bonded to the honeycomb to form an assembly thereof, which is then dried and fired to form a unified monolithic honeycomb structure. The insertion is best carried out by mounting a member in the shape of a tube on a mandrel, and inserting the mandrel into the honeycomb opening to bond the tube to the honeycomb.
Method of fabricating a honeycomb structure
Holleran, L.M.; Lipp, G.D.
1999-08-03
A method of fabricating a monolithic honeycomb structure product involves shaping a first mixture of raw materials and a binder into a green honeycomb, extruding a second mixture of raw materials and a binder into one or more green members that each define an opening extending longitudinally therethrough. The raw materials of the second mixture are compatible with the raw materials of the first mixture. The green honeycomb and member(s) are dried. The binders of the green honeycomb and member(s) are softened at the surfaces that are to be bonded. The green member(s) is inserted into the honeycomb and bonded to the honeycomb to form an assembly thereof, which is then dried and fired to form a unified monolithic honeycomb structure. The insertion is best carried out by mounting a member in the shape of a tube on a mandrel, and inserting the mandrel into the honeycomb opening to bond the tube to the honeycomb. 7 figs.
Mahadevappa, Nagabhushana; Kochhar, Gaurav; Vilvapathy, Karthikeyan Senguttuvan; Dharwadkar, Sachin; Kumar, Sumit
2016-01-01
Objectives: To study retrospectively the frequency, demographic, phenomenological, and psychiatric profile in patients presented with self-insertion of foreign bodies in the lower genitourinary tract in our institute. Materials and Methods: From January 2009 to 2015, the records of patients admitted with self-insertion of foreign bodies into the lower urinary tract were analyzed retrospectively regarding demographic and phenomenological profile, the mode of presentation, diagnosis, management, complications, and possible contributing factors leading to the event. Results: Out of 17,978 inpatients, ten patients (0.055%) presented with foreign body insertion in the lower genitourinary tract in last 6 years. Mean age was 28.1 ± 13.9 (7–50) years. Objects used for insertion were varied from seeds, twigs to the electric wire. The contributing factors were lack of partner, misconception about masturbation, and underlying psychiatric illness. The presenting symptoms were pain and swelling of the penis, difficulty in voiding, and skin ulceration. The diagnosis was possible by simple observation in four patients, X-ray kidney, ureter, and bladder, and sonography of the pelvis in six patients. Five patients had endoscopic retrieval of foreign body, 2 had an open, suprapubic cystotomy, urethrotomy was needed in one patient, and forceps removal in two patients. There were no postoperative complications. Psychiatric profile was evaluated in nine patients. Conclusions: Foreign body insertion to lower urinary tract was rare. A main cause for insertion of foreign bodies was autoerotism, misconceptions regarding masturbation, and underlying psychiatric illness. In addition to suitable method of surgical removal, counseling and psychiatric evaluation are necessary to prevent recurrences or for early detection of psychiatric problems. PMID:27453657
"Turn-of-the-Nut" Method Is Not Appropriate for Use in Cancellous Bone.
Ryan, Melissa K; Mohtar, Aaron A; Costi, John J; Reynolds, Karen J
2015-11-01
The level to which bone screws are tightened is determined subjectively by the operating surgeon. It is likely that the tactile feedback that surgeons rely on is based on localized tissue yielding, which may predispose the screw-bone interface to failure. A limited number of studies have investigated the ratio between clinical tightening torque and stripping torque. The purpose of this study was to measure, for the first time, the ratio between yield torque (T yield) and stripping torque (T max) during screw insertion into the cancellous bone and to compare these torques with clinical levels of tightening reported in the literature. Additionally, a rotational limit was investigated as a potential end point for screw insertion in cancellous bone. A 6.5-mm outer diameter commercial cancellous bone screw was inserted into human femoral head specimens (n = 89). Screws were inserted to failure, while recording insertion torque, compression under the screw head, and rotation angle. The median, interquartile ranges, and coefficient of variation were calculated for each of the following parameters: T yield, T max, T yield/T max, slope, T plateau, and rotation angle. The median ratio of T yield/T max and rotation angle was 85.45% and 96.5 degrees, respectively. The coefficient of variation was greatest for the rotation angle compared with the ratio of T yield/T max (0.37 vs. 0.12). The detection of yield may be a more precise method than the rotation angle in cancellous bone; however, bone-screw constructs that exhibit a T yield close to T max may be more susceptible to stripping during insertion. Future work can identify factors that influence the ratio of T yield/T max may help to reduce the incidence of screw stripping.
Insertion of Ag atoms into layered MoO{sub 3} via a template route
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shao, Ke, E-mail: shaoke@szu.edu.cn; Wang, Hao
2012-11-15
Graphical abstract: PVP–Ag{sup +} complex self-assembled with inorganic (Mo{sub x}O{sub y}){sub ∞}{sup n−} chains into a layered hybrid, in which the PVP–Ag complex was intercalated between the (Mo{sub x}O{sub y}){sub ∞}{sup n−} layers. Calcinations of this hybrid at 500 °C lead to formation of Ag/MoO{sub 3} nanohybrid. By this method we have successfully inserted Ag atoms into the semiconductor MoO{sub 3} lattice. Display Omitted Highlights: ► We fabricated a PVP–Ag/polyoxomolybdate layered hybrid via in situ self-assembly. ► The PVP–Ag complex has been inserted between the molybdenum oxide layers. ► This layered hybrid transformed into Ag/MoO{sub 3} nanocomposite after calcinations. ►more » HR-TEM images show that Ag atoms of about 1 nm have been inserted in the MoO{sub 3} layers. -- Abstract: We report insertion of Ag atoms into layered MoO{sub 3} via an in situ template route. PVP–Ag{sup +} complex self-assembled with inorganic (Mo{sub x}O{sub y}){sub ∞}{sup n−} chains into a layered hybrid, in which the PVP–Ag complex was intercalated between the (Mo{sub x}O{sub y}){sub ∞}{sup n−} layers. Calcinations of this hybrid at 500 °C lead to formation of Ag/MoO{sub 3} hybrid, in which Ag nanoparticles of about 1 nm have been inserted between the MoO{sub 3} layers. By this method pillared MoO{sub 3} has been obtained very easily. We believe that this research opens new routes to fabricate novel intercalation compounds and metal/semiconductor nanohybrids via an efficient and green route.« less
Method of generating ploynucleotides encoding enhanced folding variants
Bradbury, Andrew M.; Kiss, Csaba; Waldo, Geoffrey S.
2017-05-02
The invention provides directed evolution methods for improving the folding, solubility and stability (including thermostability) characteristics of polypeptides. In one aspect, the invention provides a method for generating folding and stability-enhanced variants of proteins, including but not limited to fluorescent proteins, chromophoric proteins and enzymes. In another aspect, the invention provides methods for generating thermostable variants of a target protein or polypeptide via an internal destabilization baiting strategy. Internally destabilization a protein of interest is achieved by inserting a heterologous, folding-destabilizing sequence (folding interference domain) within DNA encoding the protein of interest, evolving the protein sequences adjacent to the heterologous insertion to overcome the destabilization (using any number of mutagenesis methods), thereby creating a library of variants. The variants in the library are expressed, and those with enhanced folding characteristics selected.
A stratified charge research engine and test stand were designed and built for this work. The primary goal of this project was to evaluate the feasibility of using a removal integral injector ignition source insert which allows a convenient method of charging the relative locat...
Inserting new technology into small missions
NASA Technical Reports Server (NTRS)
Deutsch, L. J.
2001-01-01
Part of what makes small missions small is that they have less money. Executing missions at low cost implies extensive use of cost sharing with other missions or use of existing solutions. However, in order to create many small missions, new technology must be developed, applied, and assimilated. Luckily, there are methods for creating new technology and inserting it into faster-better-cheaper (FBC) missions.
Hasan, S T; Shanahan, D A; Pridie, A K; Neal, D E
1996-01-01
A method is described for percutaneous localization of the sacral foramina, for neuromodulation of bladder function. We carried out an anatomical study of 5 male and 5 female human cadaver pelves. Using the described surface markings, needles were placed percutaneously into all sacral foramina from nine different angles. Paths of needle entry were studied by subsequent dissection. We observed that although it was possible to enter any sacral foramen at a wide range of insertion angles, the incidence of nerve root/vascular penetration increased with increasing angle of needle entry. Also, the incidence of nerve root penetration was higher with the medial approach compared with lateral entry. The insertion of a needle into the S1 foramen was associated with a higher incidence of nerve root penetration and presents a potential for arterial haemorrhage. On the other hand the smaller S3 and S4 nerve roots were surrounded by venous plexuses, presenting a potential source of venous haemorrhage during procedures. Our study suggests a new method for identifying the surface markings of sacral foramina and it describes the paths of inserted needles into the respective foramina. In addition, it has highlighted some potential risk factors secondary to needle insertion.
Xiao, Dinghua; Liu, Shaojun; Yan, Hanguang; Wang, Xiaoyan
2018-05-28
To explore the function of esophageal small balloon or papillary sphincter knife in the treatment of stent implantation for colorectal malignant obstruction, and to improve the success rate of colonic stent placement in such patients. Methods: A total of 49 patients with colorectal cancer complicated with almost complete obstruction or colorectal cancer were enrolled for this study. The esophageal small balloon or papillary sphincter knife was used in the guide wires. The guide wires gradually crossed the tumor gap and they were placed in the contralateral intestinal cavity with balloon progression. X-ray was then used to confirm whether the guide wire was inserted in the lesion intestinal cavity, and then the metal bare stent was inserted. Results: The guide wires was successfully inserted with conventional methods in these 49 cases, while they were also successfully placed the guide wire and the stent in the new way. Conclusion: For the patients with colorectal cancer complicated with complete obstruction or colorectal cancer located in obviously angled location, the use of esophageal small balloon or papillary sphincter knife can help the guide wire insert. They greatly improve the success rate of stent implantation.
Does Needle Rotation Improve Lesion Targeting?
Badaan, Shadi; Petrisor, Doru; Kim, Chunwoo; Mozer, Pierre; Mazilu, Dumitru; Gruionu, Lucian; Patriciu, Alex; Cleary, Kevin; Stoianovici, Dan
2011-01-01
Background Image-guided robots are manipulators that operate based on medical images. Perhaps the most common class of image-guided robots are robots for needle interventions. Typically, these robots actively position and/or orient a needle guide, but needle insertion is still done by the physician. While this arrangement may have safety advantages and keep the physician in control of needle insertion, actuated needle drivers can incorporate other useful features. Methods We first present a new needle driver that can actively insert and rotate a needle. With this device we investigate the use of needle rotation in controlled in-vitro experiments performed with a specially developed revolving needle driver. Results These experiments show that needle rotation can improve targeting and may reduce errors by as much as 70%. Conclusion The new needle driver provides a unique kinematic architecture that enables insertion with a compact mechanism. Perhaps the most interesting conclusion of the study is that lesions of soft tissue organs may not be perfectly targeted with a needle without using special techniques, either manually or with a robotic device. The results of this study show that needle rotation may be an effective method of reducing targeting errors. PMID:21360796
Swingle, Brian
2013-09-06
We compute the entanglement entropy of a wide class of models that may be characterized as describing matter coupled to gauge fields. Our principle result is an entanglement sum rule that states that the entropy of the full system is the sum of the entropies of the two components. In the context of the models we consider, this result applies to the full entropy, but more generally it is a statement about the additivity of universal terms in the entropy. Our proof simultaneously extends and simplifies previous arguments, with extensions including new models at zero temperature as well as the ability to treat finite temperature crossovers. We emphasize that while the additivity is an exact statement, each term in the sum may still be difficult to compute. Our results apply to a wide variety of phases including Fermi liquids, spin liquids, and some non-Fermi liquid metals. For example, we prove that our model of an interacting Fermi liquid has exactly the log violation of the area law for entanglement entropy predicted by the Widom formula in agreement with earlier arguments.
Wright, Emily M; Fagan, Abigail A
2013-05-01
Although the cycle of violence theory has received empirical support (Widom, 1989a, 1989b), in reality, not all victims of child physical abuse become involved in violence. Therefore, little is known regarding factors that may moderate the relationship between abuse and subsequent violence, particularly contextual circumstances. The current investigation used longitudinal data from 1,372 youth living in 79 neighborhoods who participated in the Project on Human Development in Chicago Neighborhoods (PHDCN), and it employed a multivariate, multilevel Rasch model to explore the degree to which neighborhood disadvantage and cultural norms attenuate or strengthen the abuse-violence relationship. The results indicate that the effect of child physical abuse on violence was weaker in more disadvantaged communities. Neighborhood cultural norms regarding tolerance for youth delinquency and fighting among family and friends did not moderate the child abuse-violence relationship, but each had a direct effect on violence, such that residence in neighborhoods more tolerant of delinquency and fighting increased the propensity for violence. These results suggest that the cycle of violence may be contextualized by neighborhood structural and cultural conditions.
The wasteland of random supergravities
NASA Astrophysics Data System (ADS)
Marsh, David; McAllister, Liam; Wrase, Timm
2012-03-01
We show that in a general {N} = {1} supergravity with N ≫ 1 scalar fields, an exponentially small fraction of the de Sitter critical points are metastable vacua. Taking the superpotential and Kähler potential to be random functions, we construct a random matrix model for the Hessian matrix, which is well-approximated by the sum of a Wigner matrix and two Wishart matrices. We compute the eigenvalue spectrum analytically from the free convolution of the constituent spectra and find that in typical configurations, a significant fraction of the eigenvalues are negative. Building on the Tracy-Widom law governing fluctuations of extreme eigenvalues, we determine the probability P of a large fluctuation in which all the eigenvalues become positive. Strong eigenvalue repulsion makes this extremely unlikely: we find P ∝ exp(- c N p ), with c, p being constants. For generic critical points we find p ≈ 1 .5, while for approximately-supersymmetric critical points, p ≈ 1 .3. Our results have significant implications for the counting of de Sitter vacua in string theory, but the number of vacua remains vast.
Liquid-liquid critical point in a simple analytical model of water.
Urbic, Tomaz
2016-10-01
A statistical model for a simple three-dimensional Mercedes-Benz model of water was used to study phase diagrams. This model on a simple level describes the thermal and volumetric properties of waterlike molecules. A molecule is presented as a soft sphere with four directions in which hydrogen bonds can be formed. Two neighboring waters can interact through a van der Waals interaction or an orientation-dependent hydrogen-bonding interaction. For pure water, we explored properties such as molar volume, density, heat capacity, thermal expansion coefficient, and isothermal compressibility and found that the volumetric and thermal properties follow the same trends with temperature as in real water and are in good general agreement with Monte Carlo simulations. The model exhibits also two critical points for liquid-gas transition and transition between low-density and high-density fluid. Coexistence curves and a Widom line for the maximum and minimum in thermal expansion coefficient divides the phase space of the model into three parts: in one part we have gas region, in the second a high-density liquid, and the third region contains low-density liquid.
Liquid-liquid critical point in a simple analytical model of water
NASA Astrophysics Data System (ADS)
Urbic, Tomaz
2016-10-01
A statistical model for a simple three-dimensional Mercedes-Benz model of water was used to study phase diagrams. This model on a simple level describes the thermal and volumetric properties of waterlike molecules. A molecule is presented as a soft sphere with four directions in which hydrogen bonds can be formed. Two neighboring waters can interact through a van der Waals interaction or an orientation-dependent hydrogen-bonding interaction. For pure water, we explored properties such as molar volume, density, heat capacity, thermal expansion coefficient, and isothermal compressibility and found that the volumetric and thermal properties follow the same trends with temperature as in real water and are in good general agreement with Monte Carlo simulations. The model exhibits also two critical points for liquid-gas transition and transition between low-density and high-density fluid. Coexistence curves and a Widom line for the maximum and minimum in thermal expansion coefficient divides the phase space of the model into three parts: in one part we have gas region, in the second a high-density liquid, and the third region contains low-density liquid.
WRIGHT, EMILY M.; FAGAN, ABIGAIL A.
2013-01-01
Although the cycle of violence theory has received empirical support (Widom, 1989a, 1989b), in reality, not all victims of child physical abuse become involved in violence. Therefore, little is known regarding factors that may moderate the relationship between abuse and subsequent violence, particularly contextual circumstances. The current investigation used longitudinal data from 1,372 youth living in 79 neighborhoods who participated in the Project on Human Development in Chicago Neighborhoods (PHDCN), and it employed a multivariate, multilevel Rasch model to explore the degree to which neighborhood disadvantage and cultural norms attenuate or strengthen the abuse–violence relationship. The results indicate that the effect of child physical abuse on violence was weaker in more disadvantaged communities. Neighborhood cultural norms regarding tolerance for youth delinquency and fighting among family and friends did not moderate the child abuse–violence relationship, but each had a direct effect on violence, such that residence in neighborhoods more tolerant of delinquency and fighting increased the propensity for violence. These results suggest that the cycle of violence may be contextualized by neighborhood structural and cultural conditions. PMID:25147403
Towards a microscopic description of the free-energy landscape of water.
Prada-Gracia, Diego; Shevchuk, Roman; Hamm, Peter; Rao, Francesco
2012-10-14
Free-energy landscape theory is often used to describe complex molecular systems. Here, a microscopic description of water structure and dynamics based on configuration-space-networks and molecular dynamics simulations of the TIP4P/2005 model is applied to investigate the free-energy landscape of water. The latter is built on top of a large set of water microstates describing the kinetic stability of local hydrogen-bond arrangements up to the second solvation shell. In temperature space, the landscape displays three different regimes. At around ambient conditions, the free-energy surface is characterized by many short-lived basins of attraction which are structurally well-defined (inhomogeneous regime). At lower temperatures instead, the liquid rapidly becomes homogeneous. In this regime, the free energy is funneled-like, with fully coordinated water arrangements at the bottom of the funnel. Finally, a third regime develops below the temperature of maximal compressibility (Widom line) where the funnel becomes steeper with few interconversions between microstates other than the fully coordinated ones. Our results present a way to manage the complexity of water structure and dynamics, connecting microscopic properties to its ensemble behavior.
Extreme statistics and index distribution in the classical 1d Coulomb gas
NASA Astrophysics Data System (ADS)
Dhar, Abhishek; Kundu, Anupam; Majumdar, Satya N.; Sabhapandit, Sanjib; Schehr, Grégory
2018-07-01
We consider a 1D gas of N charged particles confined by an external harmonic potential and interacting via the 1D Coulomb potential. For this system we show that in equilibrium the charges settle, on an average, uniformly and symmetrically on a finite region centred around the origin. We study the statistics of the position of the rightmost particle and show that the limiting distribution describing its typical fluctuations is different from the Tracy–Widom distribution found in the 1D log-gas. We also compute the large deviation functions which characterise the atypical fluctuations of far away from its mean value. In addition, we study the gap between the two rightmost particles as well as the index N + , i.e. the number of particles on the positive semi-axis. We compute the limiting distributions associated to the typical fluctuations of these observables as well as the corresponding large deviation functions. We provide numerical supports to our analytical predictions. Part of these results were announced in a recent letter, Dhar et al (2017 Phys. Rev. Lett. 119 060601).
Enhanced electrocaloric effect in displacive-type organic ferroelectrics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ding, L. J., E-mail: dinglinjie82@126.com; Zhong, Y.; Fan, S. W.
2015-08-07
We explore the intrinsic feature of electrocaloric effect (ECE) accompanied by ferroelectric (FE)-paraelectric (PE) transition for displacive-type organic ferroelectrics using Green's function theory. It is demonstrated that decreasing elastic constant K or increasing spin-lattice coupling λ can enhance the ECE, as well as polarization P and transition temperature T{sub C}. Indeed, one expects that the optimal operating temperature for solid-state refrigeration is around room temperature, at which the ECE achieves its maximum. As T{sub C} is tuned to ∼310 K, it presents larger ECE response and remanent polarization with lower coercive field for smaller K value, suggesting that well flexible displacive-typemore » organic ferroelectrics are excellent candidates both for electric cooling and data storage in the design of nonvolatile FE random-access memories. Furthermore, in an electric field, it provides a bridge between a Widom line that denotes FE-PE crossover above T{sub C} and a metaelectric transition line below T{sub C} that demonstrates an FE switching behavior with an antiparallel field.« less
Ker, Katharine; Tansley, Gavin; Beecher, Deirdre; Perner, Anders; Shakur, Haleema; Harris, Tim; Roberts, Ian
2015-02-26
Dehydration is an important cause of death in patients with Ebola virus disease (EVD). Parenteral fluids are often required in patients with fluid requirements in excess of their oral intake. The peripheral intravenous route is the most commonly used method of parenteral access, but inserting and maintaining an intravenous line can be challenging in the context of EVD. Therefore it is important to consider the advantages and disadvantages of different routes for achieving parenteral access (e.g. intravenous, intraosseous, subcutaneous and intraperitoneal). To compare the reliability, ease of use and speed of insertion of different parenteral access methods. We ran the search on 17 November 2014. We searched the Cochrane Injuries Group's Specialised Register, Cochrane Central Register of Controlled Trials (CENTRAL, The Cochrane Library), Ovid MEDLINE(R) In-Process & Other Non-Indexed Citations, Ovid MEDLINE(R) Daily, Ovid MEDLINE(R) and Ovid OLDMEDLINE(R), Embase Classic + Embase (OvidSP), CINAHL (EBSCOhost), clinicaltrials.gov and screened reference lists. Randomised controlled trials comparing different parenteral routes for the infusion of fluids or medication. Two review authors examined the titles and abstracts of records obtained by searching the electronic databases to determine eligibility. Two review authors extracted data from the included trials and assessed the risk of bias. Outcome measures of interest were success of insertion; time required for insertion; number of insertion attempts; number of dislodgements; time period with functional access; local site reactions; clinicians' perception of ease of administration; needlestick injury to healthcare workers; patients' discomfort; and mortality. For trials involving the administration of fluids we also collected data on the volume of fluid infused, changes in serum electrolytes and markers of renal function. We rated the quality of the evidence as 'high', 'moderate', 'low' or 'very low' according to the GRADE approach for the following outcomes: success of insertion, time required for insertion, number of dislodgements, volume of fluid infused and needlestick injuries. We included 17 trials involving 885 participants. Parenteral access was used to infuse fluids in 11 trials and medications in six trials. None of the trials involved patients with EVD. Intravenous and intraosseous access was compared in four trials; intravenous and subcutaneous access in 11; peripheral intravenous and intraperitoneal access in one; saphenous vein cutdown and intraosseous access in one; and intraperitoneal with subcutaneous access in one. All of the trials assessing the intravenous method involved peripheral intravenous access.We judged few trials to be at low risk of bias for any of the assessed domains.Compared to the intraosseous group, patients in the intravenous group were more likely to experience an insertion failure (risk ratio (RR) 3.89, 95% confidence interval (CI) 2.39 to 6.33; n = 242; GRADE rating: low). We did not pool data for time to insertion but estimates from the trials suggest that inserting intravenous access takes longer (GRADE rating: moderate). Clinicians judged the intravenous route to be easier to insert (RR 0.15, 95% CI 0.04 to 0.61; n = 182). A larger volume of fluids was infused via the intravenous route (GRADE rating: moderate). There was no evidence of a difference between the two routes for any other outcomes, including adverse events.Compared to the subcutaneous group, patients in the intravenous group were more likely to experience an insertion failure (RR 14.79, 95% CI 2.87 to 76.08; n = 238; GRADE rating: moderate) and dislodgement of the device (RR 3.78, 95% CI 1.16 to 12.34; n = 67; GRADE rating: low). Clinicians also judged the intravenous route as being more difficult to insert and patients were more likely to be agitated in the intravenous group. Patients in the intravenous group were more likely to develop a local infection and phlebitis, but were less likely to develop erythema, oedema or swelling than those in the subcutaneous group. A larger volume of fluids was infused into patients via the intravenous route. There was no evidence of a difference between the two routes for any other outcome.There were insufficient data to reliably determine if the risk of insertion failure differed between the saphenous vein cutdown (SVC) and intraosseous method (RR 4.00, 95% CI 0.51 to 31.13; GRADE rating: low). Insertion using SVC took longer than the intraosseous method (MD 219.60 seconds, 95% CI 135.44 to 303.76; GRADE rating: moderate). There were no data and therefore there was no evidence of a difference between the two routes for any other outcome.There were insufficient data to reliably determine the relative effects of intraperitoneal or central intravenous access relative to any other parenteral access method. There are several different ways of achieving parenteral access in patients who are unable meet their fluid requirements with oral intake alone. The quality of the evidence, as assessed using the GRADE criteria, is somewhat limited because of the lack of adequately powered trials at low risk of bias. However, we believe that there is sufficient evidence to draw the following conclusions: if peripheral intravenous access can be achieved easily, this allows infusion of larger volumes of fluid than other routes; but if this is not possible, the intraosseous and subcutaneous routes are viable alternatives. The subcutaneous route may be suitable for patients who are not severely dehydrated but in whom ongoing fluid losses cannot be met by oral intake.A film to accompany this review can be viewed here (http://youtu.be/ArVPzkf93ng).
Time- and Cost-Efficient Identification of T-DNA Insertion Sites through Targeted Genomic Sequencing
Lepage, Étienne; Zampini, Éric; Boyle, Brian; Brisson, Normand
2013-01-01
Forward genetic screens enable the unbiased identification of genes involved in biological processes. In Arabidopsis, several mutant collections are publicly available, which greatly facilitates such practice. Most of these collections were generated by agrotransformation of a T-DNA at random sites in the plant genome. However, precise mapping of T-DNA insertion sites in mutants isolated from such screens is a laborious and time-consuming task. Here we report a simple, low-cost and time efficient approach to precisely map T-DNA insertions simultaneously in many different mutants. By combining sequence capture, next-generation sequencing and 2D-PCR pooling, we developed a new method that allowed the rapid localization of T-DNA insertion sites in 55 out of 64 mutant plants isolated in a screen for gyrase inhibition hypersensitivity. PMID:23951038
Transmutation of a trans-series: the Gross-Witten-Wadia phase transition
NASA Astrophysics Data System (ADS)
Ahmed, Anees; Dunne, Gerald V.
2017-11-01
We study the change in the resurgent asymptotic properties of a trans-series in two parameters, a coupling g 2 and a gauge index N, as a system passes through a large N phase transition, using the universal example of the Gross-Witten-Wadia third-order phase transition in the unitary matrix model. This transition is well-studied in the immediate vicinity of the transition point, where it is characterized by a double-scaling limit Painlevé II equation, and also away from the transition point using the pre-string difference equation. Here we present a complementary analysis of the transition at all coupling and all finite N, in terms of a differential equation, using the explicit Tracy-Widom mapping of the Gross-Witten-Wadia partition function to a solution of a Painlevé III equation. This mapping provides a simple method to generate trans-series expansions in all parameter regimes, and to study their transmutation as the parameters are varied. For example, at any finite N the weak coupling expansion is divergent, with a non-perturbative trans-series completion; on the other hand, the strong coupling expansion is convergent, and yet there is still a non-perturbative trans-series completion. We show how the different instanton terms `condense' at the transition point to match with the double-scaling limit trans-series. We also define a uniform large N strong-coupling expansion (a non-linear analogue of uniform WKB), which is much more precise than the conventional large N expansion through the transition region, and apply it to the evaluation of Wilson loops.
Generalized theory of semiflexible polymers.
Wiggins, Paul A; Nelson, Philip C
2006-03-01
DNA bending on length scales shorter than a persistence length plays an integral role in the translation of genetic information from DNA to cellular function. Quantitative experimental studies of these biological systems have led to a renewed interest in the polymer mechanics relevant for describing the conformational free energy of DNA bending induced by protein-DNA complexes. Recent experimental results from DNA cyclization studies have cast doubt on the applicability of the canonical semiflexible polymer theory, the wormlike chain (WLC) model, to DNA bending on biologically relevant length scales. This paper develops a theory of the chain statistics of a class of generalized semiflexible polymer models. Our focus is on the theoretical development of these models and the calculation of experimental observables. To illustrate our methods, we focus on a specific, illustrative model of DNA bending. We show that the WLC model generically describes the long-length-scale chain statistics of semiflexible polymers, as predicted by renormalization group arguments. In particular, we show that either the WLC or our present model adequately describes force-extension, solution scattering, and long-contour-length cyclization experiments, regardless of the details of DNA bend elasticity. In contrast, experiments sensitive to short-length-scale chain behavior can in principle reveal dramatic departures from the linear elastic behavior assumed in the WLC model. We demonstrate this explicitly by showing that our toy model can reproduce the anomalously large short-contour-length cyclization factors recently measured by Cloutier and Widom. Finally, we discuss the applicability of these models to DNA chain statistics in the context of future experiments.
The association between cecal insertion time and colorectal neoplasm detection
2013-01-01
Background Information on the impact of cecal insertion time on colorectal neoplasm detection is limited. Our objective was to determine the association between cecal insertion time and colorectal neoplasm detection rate in colonoscopy screening. Methods We performed a cross-sectional study of 12,679 consecutive subjects aged 40–79 years undergoing screening colonoscopy in routine health check-ups at the Center for Health Promotion of the Samsung Medical Center from December 2007 to June 2009. Fixed effects logistic regression conditioning on colonoscopist was used to eliminate confounding due to differences in technical ability and other characteristics across colonoscopists. Results The mean cecal insertion time was 5.9 (SD, 4.4 minutes). We identified 4,249 (33.5%) participants with colorectal neoplasms, of whom 1,956 had small single adenomas (<5 mm), 595 had medium single adenomas (5–9 mm), and 1,699 had multiple adenomas or advanced colorectal neoplasms. The overall rates of colorectal neoplasm detection by quartiles of cecal insertion time were 36.8%, 33.4%, 32.7%, and 31.0%, respectively (p trend <0.001).The odds for small single colorectal adenoma detection was 16% lower (adjusted OR 0.84; 95% CI 0.71 to 0.99) in the fourth compared to the first quartile of insertion time (p trend 0.005). Insertion time was not associated with the detection rate of single adenomas ≥5 mm, multiple adenomas or advanced colorectal neoplasms. Conclusion Shorter insertion times were associated with increased rates of detection of small colorectal adenomas <5 mm. Cecal insertion time may be clinically relevant as missed small colorectal adenomas may progress to more advanced lesions. PMID:23915303
Evaluation of preferable insertion routes for esophagogastroduodenoscopy using ultrathin endoscopes
Ono, Satoshi; Niimi, Keiko; Fujishiro, Mitsuhiro; Takahashi, Yu; Sakaguchi, Yoshiki; Nakayama, Chiemi; Minatsuki, Chihiro; Matsuda, Rie; Hirayama-Asada, Itsuko; Tsuji, Yosuke; Mochizuki, Satoshi; Kodashima, Shinya; Yamamichi, Nobutake; Ozeki, Atsuko; Matsumoto, Lumine; Ohike, Yumiko; Yamazaki, Tsutomu; Koike, Kazuhiko
2014-01-01
AIM: To evaluate the discomfort associated with esophagogastroduodenoscopy (EGD) using an ultrathin endoscope through different insertion routes. METHODS: This study (January 2012-March 2013) included 1971 consecutive patients [male/female (M/F), 1158/813, 57.5 ± 11.9 years] who visited a single institute for annual health checkups. Transnasal EGD was performed in 1394 patients and transoral EGD in 577. EGD-associated discomfort was assessed using a visual analog scale score (VAS score: 0-10). RESULTS: Multivariate analysis revealed gender (M vs F: 4.02 ± 2.15 vs 5.06 ± 2.43) as the only independent predictor of the VAS score in 180 patients who underwent EGD for the first time; whereas it revealed gender (M vs F 3.60 ± 2.20 vs 4.84 ± 2.37), operator, age group (A: < 39 years; B: 40-49 years; C: 50-59 years; D: 60-69 years; E: > 70 years; A/B/C/D/E: 4.99 ± 2.32/4.34 ± 2.49/4.19 ± 2.31/3.99 ± 2.27/3.63 ± 2.31), and type of insertion as independent predictors in the remaining patients. Subanalysis for gender, age group, and insertion route revealed that the VAS score decreased with age regardless of gender and insertion route, was high in female patients regardless of age and insertion route, and was low in males aged over 60 years who underwent transoral insertion. CONCLUSION: Although comprehensive analysis revealed that the insertion route may not be an independent predictor of the VAS score, transoral insertion may reduce EGD-associated discomfort in elderly patients. PMID:24803817
Effects of insertion speed and trocar stiffness on the accuracy of needle position for brachytherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
McGill, Carl S.; Schwartz, Jonathon A.; Moore, Jason Z.
2012-04-15
Purpose: In prostate brachytherapy, accurate positioning of the needle tip to place radioactive seeds at its target site is critical for successful radiation treatment. During the procedure, needle deflection leads to seed misplacement and suboptimal radiation dose to cancerous cells. In practice, radiation oncologists commonly use high-speed hand needle insertion to minimize displacement of the prostate as well as the needle deflection. Effects of speed during needle insertion and stiffness of trocar (a solid rod inside the hollow cannula) on needle deflection are studied. Methods: Needle insertion experiments into phantom were performed using a 2{sup 2} factorial design (2 parametersmore » at 2 levels), with each condition having replicates. Analysis of the deflection data included calculating the average, standard deviation, and analysis of variance (ANOVA) to find significant single and two-way interaction factors. Results: The stiffer tungsten carbide trocar is effective in reducing the average and standard deviation of needle deflection. The fast insertion speed together with the stiffer trocar generated the smallest average and standard deviation for needle deflection for almost all cases. Conclusions: The combination of stiff tungsten carbide trocar and fast needle insertion speed are important to decreasing needle deflection. The knowledge gained from this study can be used to improve the accuracy of needle insertion during brachytherapy procedures.« less
Despott, Edward J; Murino, Alberto; Bourikas, Leonidas; Nakamura, Masanao; Ramachandra, Vino; Fraser, Chris
2015-05-01
Spiral enteroscopy is a recently introduced technology alternative to balloon-assisted enteroscopy for examination of the small bowel. To compare small bowel insertion depths and procedure duration by spiral enteroscopy and double-balloon enteroscopy performed in the same cohort of patients, in immediate succession, using the same method of insertion depth estimation. A prospective, back-to-back comparative study was performed in 15 patients. Spiral enteroscopy procedures were performed first and a tattoo was placed to mark the most distal point. Double-balloon enteroscopy passed the tattoo placed at spiral enteroscopy in 14/15 cases (93%). Median insertion depths for double-balloon enteroscopy and spiral enteroscopy were 265cm and 175cm, respectively (P=0.004). Median time to achieve maximal depth of insertion was significantly shorter for spiral enteroscopy compared with double-balloon enteroscopy (24min vs. 45min, respectively; P=0.0005). However, in 14 patients no differences were found in median time to reach the same insertion depth (P=0.28). Double-balloon enteroscopy achieved significantly greater small bowel insertion depth than spiral enteroscopy. Although overall double-balloon enteroscopy procedure duration was longer, the time taken to reach the same small bowel insertion depth by both spiral enteroscopy and double-balloon enteroscopy was similar. Copyright © 2015 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.
Stability of smooth and rough mini-implants: clinical and biomechanical evaluation - an in vivostudy
Vilani, Giselle Naback Lemes; Ruellas, Antônio Carlos de Oliveira; Elias, Carlos Nelson; Mattos, Cláudia Trindade
2015-01-01
Objective: To compare in vivo orthodontic mini-implants (MI) of smooth (machined) and rough (acid etched) surfaces, assessing primary and secondary stability. Methods: Thirty-six (36) MI were inserted in the mandibles of six (6) dogs. Each animal received six (6) MI. In the right hemiarch, three (3) MI without surface treatment (smooth) were inserted, whereas in the left hemiarch, another three (3) MI with acid etched surfaces (rough) were inserted. The two distal MI in each hemiarch received an immediate load of 1.0 N for 16 weeks, whereas the MI in the mesial extremity was not subject to loading. Stability was measured by insertion and removal torque, initial and final mobility and by inter mini-implant distance. Results: There was no statistical behavioral difference between smooth and rough MI. High insertion torque and reduced initial mobility were observed in all groups, as well as a reduction in removal torques in comparison with insertion torque. Rough MI presented higher removal torque and lower final mobility in comparison to smooth MI. MI did not remain static, with displacement of rough MI being smaller in comparison with smooth MI, but with no statistical difference. Conclusions: MI primary stability was greater than stability measured at removal. There was no difference in stability between smooth and rough MI when assessing mobility, displacement and insertion as well as removal torques. PMID:26560819
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gaede, S; Jordan, K; Western University, London, ON
Purpose: To present a customized programmable moving insert for the ArcCHECK™ phantom that can, in a single delivery, check both entrance dosimetry, while simultaneously verifying the delivery of respiratory-gated VMAT. Methods: The cylindrical motion phantom uses a computer-controlled stepping motor to move an insert inside a stationery sleeve. Insert motion is programmable and can include rotational motion in addition to linear motion along the axis of the cylinder. The sleeve fits securely in the bore of the ArcCHECK™. Interchangeable inserts, including an A1SL chamber, optically-stimulated luminescence dosimeters, radiochromic film, or 3D gels, allow this combination to be used for commissioning,more » routine quality assurance, and patient-specific dosimetric verification of respiratory-gated VMAT. Before clinical implementation, the effect of a moving insert on the ArcCHECK™ measurements was considered. First, the measured dose to the ArcCHECK™ containing multiple inserts in the static position was compared to the calculated dose during multiple VMAT treatment deliveries. Then, dose was measured under both sinusoidal and real-patient motion conditions to determine any effect of the moving inserts on the ArcCHECK™ measurements. Finally, dose was measured during gated VMAT delivery to the same inserts under the same motion conditions to examine any effect of various beam “on-and-off” and dose rate ramp “up-and-down”. Multiple comparisons between measured and calculated dose to different inserts were also considered. Results: The pass rate for the static delivery exceeded 98% for all measurements (3%/3mm), suggesting a valid setup for entrance dosimetry. The pass rate was not altered for any measurement delivered under motion conditions. A similar Result was observed under gated VMAT conditions, including agreement of measured and calculated dose to the various inserts. Conclusion: Incorporating a programmable moving insert within the ArcCHECK™ phantom provides an efficient verification of respiratory-gated VMAT delivery that is useful during commissioning, routine quality assurance, and patient-specific dose verification. Prototype phantom development and testing was performed in collaboration with Modus Medical Devices Inc. (London, ON). No financial support was granted.« less
Experimental investigation of the noise reduction of supersonic exhaust jets with fluidic inserts
NASA Astrophysics Data System (ADS)
Powers, Russell William Walter
The noise produced by the supersonic, high temperature jets that exhaust from military aircraft is becoming a hazard to naval personnel and a disturbance to communities near military bases. Methods to reduce the noise produced from these jets in a practical full-scale environment are difficult. The development and analysis of distributed nozzle blowing for the reduction of radiated noise from supersonic jets is described. Model scale experiments of jets that simulate the exhaust jets from typical low-bypass ratio military jet aircraft engines during takeoff are performed. Fluidic inserts are created that use distributed blowing in the divergent section of the nozzle to simulate mechanical, hardwall corrugations, while having the advantage of being an active control method. This research focuses on model scale experiments to better understand the fluidic insert noise reduction method. Distributed blowing within the divergent section of the military-style convergent divergent nozzle alters the shock structure of the jet in addition to creating streamwise vorticity for the reduction of mixing noise. Enhancements to the fluidic insert design have been performed along with experiments over a large number of injection parameters and core jet conditions. Primarily military-style round nozzles have been used, with preliminary measurements of hardwall corrugations and fluidic inserts in rectangular nozzle geometries also performed. It has been shown that the noise reduction of the fluidic inserts is most heavily dependent upon the momentum flux ratio between the injector and core jet. Maximum reductions of approximately 5.5 dB OASPL have been observed with practical mass flow rates and injection pressures. The first measurements with fluidic inserts in the presence of a forward flight stream have been performed. Optimal noise reduction occurs at similar injector parameters in the presence of forward flight. Fluidic inserts in the presence of a forward flight stream were observed to reduce the peak mixing noise below the already reduced levels by nearly 4 dB OASP and the broadband shock-associated noise by nearly 3 dB OASP. Unsteady velocity measurements are used to complement acoustic results of jets with fluidic inserts. Measured axial turbulence intensities and mean axial velocity are examined to illuminate the differences in the flow field from jets with fluidic inserts. Comparisons of laser Doppler measurements with RANS CFD simulations are shown with good agreement. Analysis of the effect of spatial turbulence on the measured quantities is performed. Experimental model scale measurements of jets with and without fluidic inserts over a simulated carrier deck are presented. The model carrier environment consists of a ground plane of adjustable distance below the jet, and a simulated jet blast deflector similar to those found in practice. Measurements are performed with far-field microphones, near-field microphones, and unsteady pressure sensors. The constructive and destructive interference that results from the interaction of the direct and reflected sound waves is observed and compared with results from free jets. The noise reduction of fluidic inserts in a realistic carrier deck environment with steering of the "quiet planes" is examined. The overall sound pressure level in heat-simulated jets is reduced by 3-5 dB depending on the specific angle and ground plane height. Jets impinging upon a modeled jet blast deflector are tested in addition to jets solely in the presence of the carrier deck. Observed modifications to the acoustic field from the presence of the jet blast deflector include downstream acoustic shielding and low frequency augmentation. The region of maximum noise radiation for heat-simulated jets from nozzles with fluidic inserts impinging on the jet blast deflector is reduced in overall sound pressure level by 4-7 dB. This region includes areas where aircraft carrier personnel are located. iv.
Identification of atypical ATRNL1 insertion to EML4-ALK fusion gene in NSCLC.
Robesova, Blanka; Bajerova, Monika; Hausnerova, Jitka; Skrickova, Jana; Tomiskova, Marcela; Dvorakova, Dana
2015-03-01
We herein present a rare case of an EML4-ALK positive patient. A 61-year-old man was diagnosed with locoregional non-small cell lung cancer (NSCLC). No EGFR mutations were detected, and therefore the ALK rearrangement was evaluated using immunohistochemistry (IHC), fluorescence in situ hybridization (FISH) and the reverse transcription PCR (RT-PCR) method for EML4-ALK. All methods showed a positive result and, therefore, the patient was treated with crizotinib with a good therapeutic response. However, a detailed RT-PCR analysis and sequencing revealed an unexpected 138 bp insertion of attractin-like 1 (ATRNL1) gene into the EML4-ALK fusion gene. In our case, the positive therapeutic response suggests that ATRNL1 insertion does not affect EML4-ALK's sensitivity to crizotinib. This case shows great EML4-ALK heterogeneity and also that basic detection methods (IHC, FISH) cannot fully specify ALK rearrangement but in many cases a full specification seems to be important for an effective TKI indication, and sequencing ALK variants might contribute to optimized patient selection. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Mucosal Perfusion Preservation by a Novel Shapeable Tissue Expander for Oral Reconstruction
Barwinska, Daria; Garner, John; Davidson, Darrell D.; Cook, Todd G.; Eckert, George J.; Tholpady, Sunil S.; March, Keith L.; Park, Kinam
2017-01-01
Background: There are few methods for expanding oral mucosa, and these often cause complications such as tissue necrosis and expander eruption. This study examines mucosal blood perfusion following insertion of a novel shapeable hydrogel tissue expander (HTE). The canine model used subgingival insertion of HTE following tooth extraction and alveolar bone reduction. The primary goal of this study was to gain understanding of epithelial perfusion and reparative responses of gingival mucosa during HTE expansion. Methods: Nine Beagle dogs underwent bilateral premolar maxillary and mandibular tooth extraction. Three to four months later, HTE-contoured inserts were implanted submucosally under the buccal surface of the alveolar ridge. After removal and following a 6- to 7-month period of healing, new HTE implants were inserted at the same sites. The area was assessed weekly for tissue perfusion and volume of expansion. Biopsies for histological analysis were performed at the time of expander removal. Results: Within 2 weeks following the second insertion, blood flow returned to baseline (defined as the values of perfusion measurements at the presurgery assessment) and remained normal until hydrogel full expansion and removal. Volume expansion analysis revealed that the hydrogel doubled in volume. Histological assessment showed no macrophage or inflammatory infiltration of the mucosa. No superficial fibrosis, decreased vascularity, or mucosal change was seen. Conclusion: Maintenance of adequate tissue perfusion is a clinically important aspect of tissue expander performance to reduce risk of device loss or injury to the patient, particularly for areas with a history of previous surgeries. PMID:28894668
Fully customized placement of orthodontic miniplates: a novel clinical technique
2014-01-01
Introduction The initial stability and survival rate of orthodontic mini-implants are highly dependent on the amount of cortical bone at their insertion site. In areas with limited bone availability, mini-plates are preferred to provide effective skeletal anchorage. The purpose of this paper was to present a new clinical technique for the insertion of mini-plates. Methods In order to apply this new technique, a cone-beam image of the insertion area is required. A software (Galaxy Sirona, Bensheim, Germany) is used to construct a three-dimensional image of the scanned area and to virtually determine the exact location of the mini-plate as well as the position of the fixation screws. A stereolithographic model (STL) is then created by means of a three-dimensional scanner. Prior to its surgical insertion, the bone plate is adapted to the stereo-lithographic model. Finally, a custom transfer jig is fabricated in order to assist with accurate placement of the mini-plate intra-operatively. Results The presented technique minimizes intra-operative decision making, because the final position of the bone plate is determined pre-surgically. This significantly reduces the duration of the surgical procedure and improves its outcome. Conclusions A novel method for surgical placement of orthodontic mini-plates is presented. The technique facilitates accurate adaptation of mini-plates and insertion of retaining surgical screws; thereby enabling clinicians to more confidently increase the use of bone plates, especially in anatomical areas where the success of non-osseointegrated mini-screws is less favorable. PMID:24886597
Treatment of Insertional Achilles Pathology With Dorsal Wedge Calcaneal Osteotomy in Athletes.
Georgiannos, Dimitrios; Lampridis, Vasilis; Vasiliadis, Angelos; Bisbinas, Ilias
2017-04-01
Insertional Achilles tendinopathy and retrocalcaneal bursitis is difficult to treat, and several operative techniques have been used after failure of conservative management. Dorsal wedge calcaneal osteotomy has been described for the treatment of insertional Achilles pathology. It was hypothesized that dorsal wedge calcaneal osteotomy would be an effective and safe method for the treatment of athletes with insertional Achilles pathology unrelieved by nonoperative measures. Fifty-two athletes (64 feet) who had painful Achilles tendon syndrome unrelieved by 6 months of nonoperative measures were treated surgically. Dorsally based wedge calcaneal osteotomy was performed through a lateral approach, and 2 staples were used for fixation. Patients were scored pre- and postoperatively with the American Orthopaedic Foot & Ankle Society (AOFAS) ankle-hindfoot and Victorian Institute of Sports of Australia-Achilles (VISA-A) scores. At a minimum follow-up of 3 years, the patients' AOFAS and VISA-A scores improved from 59.5 ± 15.0 and 65.9 ± 11.1 preoperatively to 95.7 ± 6.2 and 90.2 ± 8.4 postoperatively, respectively. Clinical results were considered excellent in 38 patients, good in 12 patients, and fair in 2 patients. Return to previous sports activity time was 21 (SD, 8.0) weeks. One patient necessitated a revision operation. Operative treatment of insertional Achilles pathology in athletes with dorsal closing wedge calcaneal osteotomy was a safe and effective method that allowed for a quicker return to previous level of sports activities compared with other techniques. Level IV, retrospective case series.
Microwave-assisted chemical insertion: a rapid technique for screening cathodes for Mg-ion batteries
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kaveevivitchai, Watchareeya; Huq, Ashfia; Manthiram, Arumugam
We report an ultrafast microwave-assisted solvothermal method for chemical insertion of Mg2+ ions into host materials using magnesium acetate [Mg(CH3COO)2] as a metal-ion source and diethylene glycol (DEG) as a reducing agent. For instance, up to 3 Mg ions per formula unit of a microporous host framework Mo2.5+yVO9+z could be inserted in as little as 30 min at 170–195 °C in air. This process is superior to the traditional method which involves the use of organometallic reagents, such as di-n-butylmagnesium [(C4H9)2Mg] and magnesium bis(2,6-di-tert-butylphenoxide) [Mg-(O-2,6-But2C6H3)2], and requires an inert atmosphere with extremely long reaction times. Considering the lack of robustmore » electrolytes for Mg-ion batteries, this facile approach can be readily used as a rapid screening technique to identify potential Mg-ion electrode hosts without the necessity of fabricating electrodes and assembling electrochemical cells. Due to the mild reaction conditions, the overall structure and morphology of the Mg-ion inserted products are maintained and the compounds can be used successfully as a cathode in Mg-ion batteries. The combined synchrotron X-ray and neutron diffraction Rietveld analysis reveals the structure of the Mg-inserted compounds and gives an insight into the interactions between the Mg ions and the open-tunnel host framework.« less
Circular permutant GFP insertion folding reporters
Waldo, Geoffrey S [Santa Fe, NM; Cabantous, Stephanie [Los Alamos, NM
2008-06-24
Provided are methods of assaying and improving protein folding using circular permutants of fluorescent proteins, including circular permutants of GFP variants and combinations thereof. The invention further provides various nucleic acid molecules and vectors incorporating such nucleic acid molecules, comprising polynucleotides encoding fluorescent protein circular permutants derived from superfolder GFP, which polynucleotides include an internal cloning site into which a heterologous polynucleotide may be inserted in-frame with the circular permutant coding sequence, and which when expressed are capable of reporting on the degree to which a polypeptide encoded by such an inserted heterologous polynucleotide is correctly folded by correlation with the degree of fluorescence exhibited.
Circular permutant GFP insertion folding reporters
Waldo, Geoffrey S; Cabantous, Stephanie
2013-02-12
Provided are methods of assaying and improving protein folding using circular permutants of fluorescent proteins, including circular permutants of GFP variants and combinations thereof. The invention further provides various nucleic acid molecules and vectors incorporating such nucleic acid molecules, comprising polynucleotides encoding fluorescent protein circular permutants derived from superfolder GFP, which polynucleotides include an internal cloning site into which a heterologous polynucleotide may be inserted in-frame with the circular permutant coding sequence, and which when expressed are capable of reporting on the degree to which a polypeptide encoded by such an inserted heterologous polynucleotide is correctly folded by correlation with the degree of fluorescence exhibited.
Circular permutant GFP insertion folding reporters
Waldo, Geoffrey S [Santa Fe, NM; Cabantous, Stephanie [Los Alamos, NM
2011-06-14
Provided are methods of assaying and improving protein folding using circular permutants of fluorescent proteins, including circular permutants of GFP variants and combinations thereof. The invention further provides various nucleic acid molecules and vectors incorporating such nucleic acid molecules, comprising polynucleotides encoding fluorescent protein circular permutants derived from superfolder GFP, which polynucleotides include an internal cloning site into which a heterologous polynucleotide may be inserted in-frame with the circular permutant coding sequence, and which when expressed are capable of reporting on the degree to which a polypeptide encoded by such an inserted heterologous polynucleotide is correctly folded by correlation with the degree of fluorescence exhibited.
Circular permutant GFP insertion folding reporters
Waldo, Geoffrey S.; Cabantous, Stephanie
2013-04-16
Provided are methods of assaying and improving protein folding using circular permutants of fluorescent proteins, including circular permutants of GFP variants and combinations thereof. The invention further provides various nucleic acid molecules and vectors incorporating such nucleic acid molecules, comprising polynucleotides encoding fluorescent protein circular permutants derived from superfolder GFP, which polynucleotides include an internal cloning site into which a heterologous polynucleotide may be inserted in-frame with the circular permutant coding sequence, and which when expressed are capable of reporting on the degree to which a polypeptide encoded by such an inserted heterologous polynucleotide is correctly folded by correlation with the degree of fluorescence exhibited.
Space Station racks weight and CG measurement using the rack insertion end-effector
NASA Technical Reports Server (NTRS)
Brewer, William V.
1994-01-01
The objective was to design a method to measure weight and center of gravity (C.G.) location for Space Station Modules by adding sensors to the existing Rack Insertion End Effector (RIEE). Accomplishments included alternative sensor placement schemes organized into categories. Vendors were queried for suitable sensor equipment recommendations. Inverse mathematical models for each category determine expected maximum sensor loads. Sensors are selected using these computations, yielding cost and accuracy data. Accuracy data for individual sensors are inserted into forward mathematical models to estimate the accuracy of an overall sensor scheme. Cost of the schemes can be estimated. Ease of implementation and operation are discussed.
NASA Astrophysics Data System (ADS)
Goss, Natasha R.; Mladenov, Natalie; Seibold, Christine M.; Chowanski, Kurt; Seitz, Leslie; Wellemeyer, T. Barret; Williams, Mark W.
2013-12-01
Atmospheric wet and dry deposition are important sources of carbon for remote alpine lakes and soils. The carbon inputs from dry deposition in alpine National Atmospheric Deposition Program (NADP) collectors, including aeolian dust and biological material, are not well constrained due to difficulties in retaining particulate matter in the collectors. Here, we developed and tested a marble insert for dry deposition collection at the Niwot Ridge Long Term Ecological Research Station (NWT LTER) Soddie site (3345 m) between 24 May and 8 November 2011. We conducted laboratory tests of the insert's effect on particulate matter (PM) mass and non-purgeable organic carbon (DOC) and found that the insert did not significantly change either measurement. Thus, the insert may enable dry deposition collection of PM and DOC at NADP sites. We then developed a method for enumerating the collected wet and dry deposition with the Flow Cytometer and Microscope (FlowCAM), a dynamic-image particle analysis tool. The FlowCAM has the potential to establish morphology, which affects particle settling and retention, through particle diameter and aspect ratio. Particle images were used to track the abundance of pollen grains over time. Qualitative image examination revealed that most particles were biological in nature, such as intact algal cells and pollen. Dry deposition loading to the Soddie site as determined by FlowCAM measurements was highly variable, ranging from 100 to >230 g ha-1 d-1 in June-August 2011 and peaking in late June. No significant difference in diameter or aspect ratio was found between wet and dry deposition, suggesting fundamental similarities between those deposition types. Although FlowCAM statistics and identification of particle types proved insightful, our total-particle enumeration method had a high variance and underestimated the total number of particles when compared to imaging of relatively large volumes (60-125 mL) from a single sample. We recommend use of the FlowCAM, especially for subclasses of particles, but in light of uncertainty in particle counts, believe that it should be paired with traditional methods such as microscopy in this stage of the technique's development. Analysis of well-mixed samples produced lower variability than settling methods used for algae samples. Use of the marble inserts in the dry deposition collector in the NADP context is recommended, and the implications of various particle counting and identification methods are explored.
METHOD AND APPARATUS FOR FABRICATING TUBULAR UNITS
Haldeman, G.W.
1959-02-24
A method and apparatus are described for fabricating tubular assemblies such as clad fuel elements for nuclear reactors. According to this method, a plurality of relatively short cylindrical slug-shaped members are inserted in an outer protective tubular jacket, and the assembly is passed through a reducing die to draw the outer tubular member into tight contact with the slug members, the slugs being automatically spaced with respect to each other and helium being inserted during the drawing operation to fill the spaces. The apparatus includes a pusher rod which functions to space the slugelements equidistantly by pushing on them in the direction of drawing but traveling at a slower rate than that of the tubular member.
Method and apparatus for duct sealing using a clog-resistant insertable injector
Wang, Duo; Modera, Mark P.
2010-12-14
A method for forming a duct access region through one side of a previously installed air duct, wherein the air duct has an air flow with an air flow direction by inserting an aerosol injector into a previously installed air duct through the access region. The aerosol injector includes a liquid tube having a liquid tube orifice for ejecting a liquid to be atomized; and a propellant cap. The method is accomplished by aligning the aerosol injector with the direction of air flow in the duct; activating an air flow within the duct; and spraying a sealant through the aerosol injector to seal the duct in the direction of the air flow.
Khedr, Ayman E.; Sayed, Mostafa
2013-01-01
CONFLICT OF INTEREST: NONE DECLARED Defect tracking systems play an important role in the software development organizations as they can store historical information about defects. There are many research in defect tracking models and systems to enhance their capabilities to be more specifically tracking, and were adopted with new technology. Furthermore, there are different studies in classifying bugs in a step by step method to have clear perception and applicable method in detecting such bugs. This paper shows a new proposed defect tracking model for the purpose of classifying the inserted defects reports in a step by step method for more enhancement of the software quality. PMID:24039334
Comparison of static and dynamic computer-assisted guidance methods in implantology.
Mischkowski, R A; Zinser, M J; Neugebauer, J; Kübler, A C; Zöller, J E
2006-01-01
The planning of dental implant position and its transfer to the operation site can be considered as one of the most important factors for the long-term success of implant-supported prosthetic and epithetic restorations. This study compares computer-assisted fabricated surgical templates as the static method with intro-operative image guided navigation as the dynamic method for transfer of three-dimensional pre-operative planning. For the static method, the systems Med3D, coDiagnostix/ gonyX, and SimPlant were used. For the dynamic method, the systems RoboDent und VectorVision2 were applied. A total of 746 implants were inserted between August 1999 and December 2005 in 206 patients. The static approach was used most frequently, accounting for 611 fixtures in 168 patients. The failure ratios within the first 6 months were 1.31% in the statically controlled insertion group compared to 2.96% in the dynamically controlled insertion group. Complications related to an incorrect position of the implants have not been observed so far in either group. All computer-assisted methods included in this study were successfully applied in a clinical setting after a certain start-up period. The indications for application of computer-assisted methods in implantology are currently given in difficult anatomical situations. Due to uncomplicated handling and low resource demands, the static template technique can be recommended as the method of choice for the majority of all cases falling into this category.
Temperature Rise in Kirschner Wires Inserted Using Two Drilling Methods: Forward and Oscillation.
Anderson, Scott Richard; Inceoglu, Serkan; Wongworawat, Montri D
2017-05-01
Kirschner wires (K-wires) are commonly used in orthopedic surgery. However, the loosening of the pins can lead to delayed or improper healing or infection. Wire loosening can occur by thermal necrosis that occurs due to heat produced during wire insertion. Although the parameters that affect temperature rise in cortical bone during wire insertion and drilling have been studied, the effect of drilling mode (oscillation versus forward) is unknown. The purpose of this study was to compare the temperature changes occurring in cortical bone during wire insertions by oscillating and forward drills. Our hypothesis is that oscillation drilling would produce less heat compared with forward drilling in K-wire insertion with 2 commonly used wire diameters. We drilled K-wires in a pig metacarpal model and measured the temperature rise between forward and oscillation drilling modes using diamond-tipped 0.062- and 0.045-inch-diameter K-wires. There were 20 holes drilled for each group (n = 20). The average temperature rise using the 0.062-inch K-wire under forward and oscillation insertion was 14.0 ± 5.5°C and 8.8 ± 2.6°C, respectively. For the 0.045-inch K-wire, under forward and oscillation insertion, the average temperature rise was 11.4 ± 2.6°C and 7.1 ± 1.9°C, respectively. The effects of the drilling mode and wire diameter on temperature rise were significant ( P < .05). In conclusion, the oscillation of K-wires during insertion causes a lower temperature rise when compared with forward drilling.
Hefny, Ashraf F; Kunhivalappil, Fathima T; Matev, Nikolay; Avila, Norman A; Bashir, Masoud O; Abu-Zidan, Fikri M
2018-01-01
INTRODUCTION Diagnoses of pneumothorax, especially occult pneumothorax, have increased as the use of computed tomography (CT) for imaging trauma patients becomes near-routine. However, the need for chest tube insertion remains controversial. We aimed to study the management of pneumothorax detected on CT among patients with blunt trauma, including the decision for tube thoracostomy, in a community-based hospital. METHODS Chest CT scans of patients with blunt trauma treated at Al Rahba Hospital, Abu Dhabi, United Arab Emirates, from October 2010 to October 2014 were retrospectively studied. Variables studied included demography, mechanism of injury, endotracheal intubation, pneumothorax volume, chest tube insertion, Injury Severity Score, hospital length of stay and mortality. RESULTS CT was performed in 703 patients with blunt trauma. Overall, pneumothorax was detected on CT for 74 (10.5%) patients. Among the 65 patients for whom pneumothorax was detected before chest tube insertion, 25 (38.5%) needed chest tube insertion, while 40 (61.5%) did not. Backward stepwise likelihood regression showed that independent factors that significantly predicted chest tube insertion were endotracheal intubation (p = 0.01), non-United Arab Emirates nationality (p = 0.01) and pneumothorax volume (p = 0.03). The receiver operating characteristic curve showed that the best pneumothorax volume that predicted chest tube insertion was 30 mL. CONCLUSION Chest tube was inserted in less than half of the patients with blunt trauma for whom pneumothorax was detected on CT. Pneumothorax volume should be considered in decision-making regarding chest tube insertion. Conservative treatment may be sufficient for pneumothorax of volume < 30 mL. PMID:28741012
Saracevic, Andrea; Simundic, Ana-Maria; Celap, Ivana; Luzanic, Valentina
2013-07-01
Rigat and colleagues were the first ones to develop a rapid PCR-based assay for identifying the angiotensin converting enzyme insertion/deletion (I/D) polymorphism. Due to a big difference between the length of the wild-type and mute alleles the PCR method is prone to mistyping because of preferential amplification of the D allele causing depicting I/D heterozygotes as D/D homozygotes. The aim of this study was to investigate whether this preferential amplification can be repressed by amplifying a longer DNA fragment in a so called Long PCR protocol. We also aimed to compare the results of genotyping using five different PCR protocols and to estimate the mistyping rate. The study included 200 samples which were genotyped using standard method used in our laboratory, a stepdown PCR, PCR protocol with the inclusion of 4 % DMSO, PCR with the use of insertion specific primers and new Long PCR method. The results of this study have shown that accurate ACE I/D polymorphism genotyping can be accomplished with the standard and the Long PCR method. Also, as of our results, accurate ACE I/D polymorphism genotyping can be accomplished regardless of the method used. Therefore, if the standard method is optimized more cautiously, accurate results can be obtained by this simple, inexpensive and rapid PCR protocol.
ERIC Educational Resources Information Center
Schneiderman, Deborah; Freihoefer, Kara
2012-01-01
Purpose: The purpose of this paper is to examine the integration of Okala curriculum into Interior Design coursework. Okala, as a teaching package, is utilized extensively in industrial design education. However, this study examines the expansion and insertion of Okala modules in an existing interior design curriculum. The Okala modules included…
Linear motion device and method for inserting and withdrawing control rods
Smith, Jay E.
1984-01-01
A linear motion device, more specifically a control rod drive mechanism (CRDM) for inserting and withdrawing control rods into a reactor core, is capable of independently and sequentially positioning two sets of control rods with a single motor stator and rotor. The CRDM disclosed can control more than one control rod lead screw without incurring a substantial increase in the size of the mechanism.
Technology Insertion for Recapitalization of Legacy Systems
2015-09-30
peened, and 4) an Abcite coating will be flame sprayed on the component. The ALCM program (B) has 1) evaluated data provided, 2) gathered questions...Report Technology Insertion for the Recapitalization of Legacy Systems Laser sintering, thermal spray and cold spray are additive manufacturing methods... coatings Need an experienced operator Requires a special spray booth to limit overspray and protect operator Requires primer or surface treatment
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-13
... hover, with litter doorpost removed is prohibited.'' This revision may be made by pen and ink changes... revision may be made by pen and ink changes, inserting a copy of this AD into the RFM, or inserting a copy... (817) 222-5961, for information about previously approved alternative methods of compliance. (c) The...
Franca, Juçara Ribeiro; Foureaux, Giselle; Fuscaldi, Leonardo Lima; Ribeiro, Tatiana Gomes; Rodrigues, Lívia Bomfim; Bravo, Renata; Castilho, Rachel Oliveira; Yoshida, Maria Irene; Cardoso, Valbert Nascimento; Fernandes, Simone Odília; Cronemberger, Sebastião; Ferreira, Anderson José; Faraco, André Augusto Gomes
2014-01-01
The purpose of the present study was to develop and assess a novel sustained-release drug delivery system of Bimatoprost (BIM). Chitosan polymeric inserts were prepared using the solvent casting method and characterized by swelling studies, infrared spectroscopy, differential scanning calorimetry, drug content, scanning electron microscopy and in vitro drug release. Biodistribution of 99mTc-BIM eye drops and 99mTc-BIM-loaded inserts, after ocular administration in Wistar rats, was accessed by ex vivo radiation counting. The inserts were evaluated for their therapeutic efficacy in glaucomatous Wistar rats. Glaucoma was induced by weekly intracameral injection of hyaluronic acid. BIM-loaded inserts (equivalent to 9.0 µg BIM) were administered once into conjunctival sac, after ocular hypertension confirmation. BIM eye drop was topically instilled in a second group of glaucomatous rats for 15 days days, while placebo inserts were administered once in a third group. An untreated glaucomatous group was used as control. Intraocular pressure (IOP) was monitored for four consecutive weeks after treatment began. At the end of the experiment, retinal ganglion cells and optic nerve head cupping were evaluated in the histological eye sections. Characterization results revealed that the drug physically interacted, but did not chemically react with the polymeric matrix. Inserts sustainedly released BIM in vitro during 8 hours. Biodistribution studies showed that the amount of 99mTc-BIM that remained in the eye was significantly lower after eye drop instillation than after chitosan insert implantation. BIM-loaded inserts lowered IOP for 4 weeks, after one application, while IOP values remained significantly high for the placebo and untreated groups. Eye drops were only effective during the daily treatment period. IOP results were reflected in RGC counting and optic nerve head cupping damage. BIM-loaded inserts provided sustained release of BIM and seem to be a promising system for glaucoma management. PMID:24788066
Finite element simulation of cutting grey iron HT250 by self-prepared Si3N4 ceramic insert
NASA Astrophysics Data System (ADS)
Wang, Bo; Wang, Li; Zhang, Enguang
2017-04-01
The finite element method has been able to simulate and solve practical machining problems, achieve the required accuracy and the highly reliability. In this paper, the simulation models based on the material properties of the self-prepared Si3N4 insert and HT250 were created. Using these models, the results of cutting force, cutting temperature and tool wear rate were obtained, and tool wear mode was predicted after cutting simulation. These approaches may develop as the new method for testing new cutting-tool materials, shortening development cycle and reducing the cost.
Compositions and methods for the expression of selenoproteins in eukaryotic cells
Gladyshev, Vadim [Lincoln, NE; Novoselov, Sergey [Puschino, RU
2012-09-25
Recombinant nucleic acid constructs for the efficient expression of eukaryotic selenoproteins and related methods for production of recombinant selenoproteins are provided. The nucleic acid constructs comprise novel selenocysteine insertion sequence (SECIS) elements. Certain novel SECIS elements of the invention contain non-canonical quartet sequences. Other novel SECIS elements provided by the invention are chimeric SECIS elements comprising a canonical SECIS element that contains a non-canonical quartet sequence and chimeric SECIS elements comprising a non-canonical SECIS element that contains a canonical quartet sequence. The novel SECIS elements of the invention facilitate the insertion of selenocysteine residues into recombinant polypeptides.
Rajic, S.; Muhs, J.D.
1996-10-22
A fiber optic connector and method for connecting composite materials within which optical fibers are imbedded are disclosed. The fiber optic connector includes a capillary tube for receiving optical fibers at opposing ends. The method involves inserting a first optical fiber into the capillary tube and imbedding the unit in the end of a softened composite material. The capillary tube is injected with a coupling medium which subsequently solidifies. The composite material is machined to a desired configuration. An external optical fiber is then inserted into the capillary tube after fluidizing the coupling medium, whereby the optical fibers are coupled. 3 figs.
NASA Technical Reports Server (NTRS)
Chaban, Galina M.
2005-01-01
Compounds formed by insertion of rare-gas atoms (Xe, Kr, and Ar) into glycine molecule are investigated using accurate ab initio computational methods. Identification of such insertion compounds may open new frontiers in the field of rare-gas chemistry, such as possible existence of biological molecules that include chemically bound rare gas atoms. The most stable glycine-Rg configuration is found to correspond to insertion of Rg atoms into the 0-H bond of glycine. These NH2CH2COORgH compounds are metastable , but separated by sizable potential barriers from the Rg + glycine dissociation products. Preliminary calculations show that NH2CH2COOXeH compound is energetically stable with respect to another (3-body) dissociation channel (NH2CH2COO + Rg + H), while the corresponding Ar species is not stable in this respect. The compound with the inserted Kr is a borderline case, with the 3-body dissociation products being close in energy to the NH2CH2COOKrH minimum.
Painless needle insertion in regional anesthesia of the eye.
Vaalamo, M O; Paloheimo, M P; Nikki, P H
1995-04-01
We examined a new technique of applying topical anesthetic with cotton tip sticks to the conjunctiva before needle insertion in regional anesthesia of the eye. Oxybuprocaine 0.4% and lidocaine 4% were compared with balanced salt solution (BSS) as topical anesthetics of the conjunctiva in Study 1. Ninety patients were randomly assigned into three groups (n = 30) to receive one of the three topical anesthetics in a double-blind manner. Pain of the needle insertions was measured with visual analog scale score (VAS) and quantitative surface electromography (qEMG). Both oxybuprocaine and lidocaine reduced pain significantly when compared to BSS. In Study 2, with healthy volunteers, we compared our previous practice of merely applying three consecutive drops of oxybuprocaine on the conjunctiva before needle insertions to the new technique of placing additional cotton tip sticks soaked in oxybuprocaine on the conjunctiva. We found the needle insertion virtually pain free when the cotton tip sticks were added to the topical anesthesia. The use of this simple method of topical anesthesia before the eye block increases patient comfort significantly.
Ladokhin, Alexey S.
2016-01-01
Experimental determination of the free energy stabilizing the structure of membrane proteins in their native lipid environment is undermined by a lack of appropriate methods and suitable model systems. Here, we demonstrate how fluorescence correlation spectroscopy can be used to characterize thermodynamics of pH-triggered bilayer insertion of nonconstitutive membrane proteins (e.g., bacterial toxins, colicins). The experimental design is guided by the appropriate thermodynamic scheme which considers two independent processes: pH-dependent formation of a membrane-competent form and its insertion into the lipid bilayer. Measurements of a model protein annexin B12 under conditions of lipid saturation demonstrate that protonation leading to the formation of the membrane-competent state occurs near membrane interface. Lipid titration experiments demonstrate that the free energy of transfer to the intermediate interfacial state is especially favorable, while the free energy of final insertion is modulated by interplay of hydrophobic and electrostatic interactions on the bilayer interface. The general principles of kinetic measurements along the insertion pathway containing interfacial intermediate are discussed and practical examples emphasizing appropriate fitting and normalization procedures are presented. PMID:21609856
Development of a reliable method to assess footwear comfort during running.
Mündermann, Anne; Nigg, Benno M; Stefanyshyn, Darren J; Humble, R Neil
2002-08-01
The purposes of this study were: (a) to determine whether subjects are able to distinguish between differences in footwear with respect to footwear comfort; and (b) to determine how reliably footwear comfort can be assessed using a visual analogue scale (VAS) and a protocol including a control condition during running. Intraclass correlation coefficients (ICCs) between comfort ratings for repeated conditions were high (ICC = 0.799). Differences in comfort ratings between the insert conditions were significant. A paired t-test revealed a significant difference in overall comfort ratings for the control insert when tested after the soft insert compared to when tested after the hard insert (P = 0.008). The results of this study showed that VASs provide a reliable measure to assess footwear comfort during running under the conditions that: (a) a control condition is included; and (b) the average comfort rating of sessions 4-6 is used. Copyright 2002 Elsevier Science B.V.
Method for Monitored Separation and Collection of Biological Materials
NASA Technical Reports Server (NTRS)
Fox, George Edward (Inventor); Jackson, George William (Inventor); Willson, Richard Coale (Inventor)
2014-01-01
A device for separating and purifying useful quantities of particles comprises: (a) an anolyte reservoir connected to an anode, the anolyte reservoir containing an electrophoresis buffer; (b) a catholyte reservoir connected to a cathode, the catholyte reservoir also containing the electrophoresis buffer; (c) a power supply connected to the anode and to the cathode; (d) a column having a first end inserted into the anolyte reservoir, a second end inserted into the catholyte reservoir, and containing a separation medium; (e) a light source; (f) a first optical fiber having a first fiber end inserted into the separation medium, and having a second fiber end connected to the light source; (g) a photo detector; (h) a second optical fiber having a third fiber end inserted into the separation medium, and having a fourth fiber end connected to the photo detector; and (i) an ion-exchange membrane in the anolyte reservoir.
NASA Astrophysics Data System (ADS)
Akim, E. L.; Zaslavsky, G. S.; Morskoy, I. M.; Ruzsky, E. G.; Stepaniants, V. A.; Tuchin, A. G.
2010-02-01
This paper is concerned with the problems of ballistics, navigation, and flight control of the space craft (SC) in the Phobos-Grunt mission. We consider an insertion into the Earth-Mars transfer trajectory, the Earth-Mars transfer, the strategy of corrections, and the accuracy of the insertion of the SC into Martian orbit. During the orbital maneuvering stage in the sphere of influence of Mars, we set up a scheme that allows for the insertion of the SC, with the prescribed accuracy, into a point 80-km above the Phobos surface over the theoretical landing area. We specify the sequence for a controlled landing and provide methods for solving the problems of navigation and control during a self-c ontained landing. We also consider the liftoff from Phobos, insertion into the parking orbit, and the Mars-Earth transfer.
Non-hydrolytic metal oxide films for perovskite halide overcoating and stabilization
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martinson, Alex B.; Kim, In Soo
A method of protecting a perovskite halide film from moisture and temperature includes positioning the perovskite halide film in a chamber. The chamber is maintained at a temperature of less than 200 degrees Celsius. An organo-metal compound is inserted into the chamber. A non-hydrolytic oxygen source is subsequently inserted into the chamber. The inserting of the organo-metal compound and subsequent inserting of the non-hydrolytic oxygen source into the chamber is repeated for a predetermined number of cycles. The non-hydrolytic oxygen source and the organo-metal compound interact in the chamber to deposit a non-hydrolytic metal oxide film on perovskite halide film.more » The non-hydrolytic metal oxide film protects the perovskite halide film from relative humidity of greater than 35% and a temperature of greater than 150 degrees Celsius, respectively.« less
Phylogenetic inference under varying proportions of indel-induced alignment gaps
Dwivedi, Bhakti; Gadagkar, Sudhindra R
2009-01-01
Background The effect of alignment gaps on phylogenetic accuracy has been the subject of numerous studies. In this study, we investigated the relationship between the total number of gapped sites and phylogenetic accuracy, when the gaps were introduced (by means of computer simulation) to reflect indel (insertion/deletion) events during the evolution of DNA sequences. The resulting (true) alignments were subjected to commonly used gap treatment and phylogenetic inference methods. Results (1) In general, there was a strong – almost deterministic – relationship between the amount of gap in the data and the level of phylogenetic accuracy when the alignments were very "gappy", (2) gaps resulting from deletions (as opposed to insertions) contributed more to the inaccuracy of phylogenetic inference, (3) the probabilistic methods (Bayesian, PhyML & "MLε, " a method implemented in DNAML in PHYLIP) performed better at most levels of gap percentage when compared to parsimony (MP) and distance (NJ) methods, with Bayesian analysis being clearly the best, (4) methods that treat gapped sites as missing data yielded less accurate trees when compared to those that attribute phylogenetic signal to the gapped sites (by coding them as binary character data – presence/absence, or as in the MLε method), and (5) in general, the accuracy of phylogenetic inference depended upon the amount of available data when the gaps resulted from mainly deletion events, and the amount of missing data when insertion events were equally likely to have caused the alignment gaps. Conclusion When gaps in an alignment are a consequence of indel events in the evolution of the sequences, the accuracy of phylogenetic analysis is likely to improve if: (1) alignment gaps are categorized as arising from insertion events or deletion events and then treated separately in the analysis, (2) the evolutionary signal provided by indels is harnessed in the phylogenetic analysis, and (3) methods that utilize the phylogenetic signal in indels are developed for distance methods too. When the true homology is known and the amount of gaps is 20 percent of the alignment length or less, the methods used in this study are likely to yield trees with 90–100 percent accuracy. PMID:19698168
Topology optimization of two-dimensional elastic wave barriers
NASA Astrophysics Data System (ADS)
Van hoorickx, C.; Sigmund, O.; Schevenels, M.; Lazarov, B. S.; Lombaert, G.
2016-08-01
Topology optimization is a method that optimally distributes material in a given design domain. In this paper, topology optimization is used to design two-dimensional wave barriers embedded in an elastic halfspace. First, harmonic vibration sources are considered, and stiffened material is inserted into a design domain situated between the source and the receiver to minimize wave transmission. At low frequencies, the stiffened material reflects and guides waves away from the surface. At high frequencies, destructive interference is obtained that leads to high values of the insertion loss. To handle harmonic sources at a frequency in a given range, a uniform reduction of the response over a frequency range is pursued. The minimal insertion loss over the frequency range of interest is maximized. The resulting design contains features at depth leading to a reduction of the insertion loss at the lowest frequencies and features close to the surface leading to a reduction at the highest frequencies. For broadband sources, the average insertion loss in a frequency range is optimized. This leads to designs that especially reduce the response at high frequencies. The designs optimized for the frequency averaged insertion loss are found to be sensitive to geometric imperfections. In order to obtain a robust design, a worst case approach is followed.
Seamless lesion insertion in digital mammography: methodology and reader study
NASA Astrophysics Data System (ADS)
Pezeshk, Aria; Petrick, Nicholas; Sahiner, Berkman
2016-03-01
Collection of large repositories of clinical images containing verified cancer locations is costly and time consuming due to difficulties associated with both the accumulation of data and establishment of the ground truth. This problem poses a significant challenge to the development of machine learning algorithms that require large amounts of data to properly train and avoid overfitting. In this paper we expand the methods in our previous publications by making several modifications that significantly increase the speed of our insertion algorithms, thereby allowing them to be used for inserting lesions that are much larger in size. These algorithms have been incorporated into an image composition tool that we have made publicly available. This tool allows users to modify or supplement existing datasets by seamlessly inserting a real breast mass or micro-calcification cluster extracted from a source digital mammogram into a different location on another mammogram. We demonstrate examples of the performance of this tool on clinical cases taken from the University of South Florida Digital Database for Screening Mammography (DDSM). Finally, we report the results of a reader study evaluating the realism of inserted lesions compared to clinical lesions. Analysis of the radiologist scores in the study using receiver operating characteristic (ROC) methodology indicates that inserted lesions cannot be reliably distinguished from clinical lesions.
Nawabi, Danyal H.; Imhauser, Carl; Tucker, Scott; Nguyen, Joseph; Wickiewicz, Thomas L.; Pearle, Andrew
2014-01-01
Objectives: Histological studies have shown that the ACL has a direct and indirect insertion on the femur [1]. The direct insertion is located along the lateral intercondylar ridge and the indirect insertion is located ‘lower’ on the lateral wall of the notch. The trend towards anatomic ACL reconstruction using the anteromedial (AM) portal technique has resulted in ‘lower’ non-isometric femoral tunnel positions and increased graft failures [2]. To our knowledge, the load transfer properties of the direct and indirect ACL insertions have not been studied. This information may help in understanding the increased failures reported with AM portal drilling. The purpose of this study was, 1) to compare the load transferred across the native ACL at the direct and indirect femoral insertions and, 2) to determine the strain behavior of ACL grafts placed at different tunnel locations within the direct and indirect insertions. Methods: Ten fresh-frozen cadaveric knees (mean age, 52.5 years; range, 29-65) were mounted to a six degree of freedom robot. A 134N anterior load at 30 and 90° flexion and a combined valgus (8Nm) and internal (4Nm) rotational moment at 15° flexion were applied. The ACL was subsequently sectioned at the femoral footprint by detaching either the direct or indirect insertion (partially sectioned state), followed by the remainder of the ACL (completely sectioned state) (Figure 1). The kinematics of the intact knee were replayed after each stage of sectioning to determine the loads transferred across the direct and indirect ACL fibers. Loads were expressed as a percentage of the total load borne by the ACL. Strain behaviour was tested by generating 3D models of the femur and tibia from CT scans of each knee. Three tunnel locations (anteromedial bundle [AM], center [C], posterolateral bundle [PL]) each were selected for the direct and indirect insertions and a virtual ACL graft was inserted. The isometry of the virtual graft was calculated through a flexion path of 0 to 90°. Results: Under an anterior tibial load at 30° flexion, the direct insertion carried 83.9% of the total ACL load compared to 16.1% in the indirect insertion (p<0.001). The direct insertion also carried more load at 90° flexion (95.2% vs 4.8%; p<0.001). Under a combined rotatory load at 15° flexion, the direct insertion carried 84.2% of the total ACL load compared to 15.8% in the indirect insertion (p<0.001). A virtual ACL graft placed at the AM position in the direct insertion demonstrated the best strain behaviour with a mean 10.9% change in length. This value was significantly lower (p<0.001) than the isometry at all 3 tunnel positions in the indirect insertion (AM = 18.5%; C = 24.9%; PL = 30.9%). Conclusion: Fibers in the direct insertion of the ACL carry more load than fibers in the indirect insertion. Virtual ACL grafts placed in the ‘higher’ direct location are more isometric than in the ‘lower’ indirect location during range of motion testing. Clinical Relevance: ‘Low’ ACL grafts in the indirect ACL insertion, resulting from AM portal drilling techniques, may experience higher loads in-vivo due to unfavorable biomechanics. With the current shift towards anatomic ACL reconstruction, it may be beneficial to create a ‘higher’ femoral tunnel within the direct insertion at the lateral intercondylar ridge. This position remains anatomical but may also be biomechanically favorable.
Precision grid and hand motion for accurate needle insertion in brachytherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
McGill, Carl S.; Schwartz, Jonathon A.; Moore, Jason Z.
2011-08-15
Purpose: In prostate brachytherapy, a grid is used to guide a needle tip toward a preplanned location within the tissue. During insertion, the needle deflects en route resulting in target misplacement. In this paper, 18-gauge needle insertion experiments into phantom were performed to test effects of three parameters, which include the clearance between the grid hole and needle, the thickness of the grid, and the needle insertion speed. Measurement apparatus that consisted of two datum surfaces and digital depth gauge was developed to quantify needle deflections. Methods: The gauge repeatability and reproducibility (GR and R) test was performed on themore » measurement apparatus, and it proved to be capable of measuring a 2 mm tolerance from the target. Replicated experiments were performed on a 2{sup 3} factorial design (three parameters at two levels) and analysis included averages and standard deviation along with an analysis of variance (ANOVA) to find significant single and two-way interaction factors. Results: Results showed that grid with tight clearance hole and slow needle speed increased precision and accuracy of needle insertion. The tight grid was vital to enhance precision and accuracy of needle insertion for both slow and fast insertion speed; additionally, at slow speed the tight, thick grid improved needle precision and accuracy. Conclusions: In summary, the tight grid is important, regardless of speed. The grid design, which shows the capability to reduce the needle deflection in brachytherapy procedures, can potentially be implemented in the brachytherapy procedure.« less
Hoskison, Emma; Mitchell, Scott; Coulson, Chris
2017-07-01
Cochlear implantation (CI) has developed from its origins in the 1980s. Initially, CI was for profound bilateral hearing impairment. However, candidacy for CI have become more widespread in recent years with unilateral implantation and an emphasis on hearing preservation. Evidence supports full electrode insertion in an atraumatic fashion into the scala tympani (ST) provides optimal hearing outcomes. The main aim of this systematic review was to elucidate the degree of trauma associated with CI insertion. A systematic literature search was undertaken using PubMed Medline. A grading system described by Eshraghi was used to classify cochlear trauma. Both radiological and histological studies were included. Twenty one papers were identified which were relevant to our search. In total, 653 implants were inserted and 115 (17.6%) showed evidence of trauma. The cochleas with trauma had basilar membrane elevation in 5.2%, ruptured in 5.2%, the electrode passed from the ST to the SV in 84.4% and there was grade 4 trauma in 5.2%. The studies used a variety of histological and radiological methods to assess for evidence of trauma in both cadaveric temporal bones and live recipients. Minimizing cochlear trauma during implant insertion is important to preserve residual hearing and optimize audiological performance. An overall 17.6% trauma rate suggests that CI insertion could be improved with more accurate and consistent electrode insertion such as in the form of robotic guidance. The correlation of cochlea trauma with post-operative hearing has yet to be determined.
The insertional history of an active family of L1 retrotransposons in humans.
Boissinot, Stéphane; Entezam, Ali; Young, Lynn; Munson, Peter J; Furano, Anthony V
2004-07-01
As humans contain a currently active L1 (LINE-1) non-LTR retrotransposon family (Ta-1), the human genome database likely provides only a partial picture of Ta-1-generated diversity. We used a non-biased method to clone Ta-1 retrotransposon-containing loci from representatives of four ethnic populations. We obtained 277 distinct Ta-1 loci and identified an additional 67 loci in the human genome database. This collection represents approximately 90% of the Ta-1 population in the individuals examined and is thus more representative of the insertional history of Ta-1 than the human genome database, which lacked approximately 40% of our cloned Ta-1 elements. As both polymorphic and fixed Ta-1 elements are as abundant in the GC-poor genomic regions as in ancestral L1 elements, the enrichment of L1 elements in GC-poor areas is likely due to insertional bias rather than selection. Although the chromosomal distribution of Ta-1 inserts is generally a function of chromosomal length and gene density, chromosome 4 significantly deviates from this pattern and has been much more hospitable to Ta-1 insertions than any other chromosome. Also, the intra-chromosomal distribution of Ta-1 elements is not uniform. Ta-1 elements tend to cluster, and the maximal gaps between Ta-1 inserts are larger than would be expected from a model of uniform random insertion. Copyright 2004 Cold Spring Harbor Laboratory Press ISSN
DOE Office of Scientific and Technical Information (OSTI.GOV)
Borot de Battisti, M; Maenhout, M; Lagendijk, J J W
Purpose: To develop a new method which adaptively determines the optimal needle insertion sequence for HDR prostate brachytherapy involving divergent needle-by-needle dose delivery by e.g. a robotic device. A needle insertion sequence is calculated at the beginning of the intervention and updated after each needle insertion with feedback on needle positioning errors. Methods: Needle positioning errors and anatomy changes may occur during HDR brachytherapy which can lead to errors in the delivered dose. A novel strategy was developed to calculate and update the needle sequence and the dose plan after each needle insertion with feedback on needle positioning errors. Themore » dose plan optimization was performed by numerical simulations. The proposed needle sequence determination optimizes the final dose distribution based on the dose coverage impact of each needle. This impact is predicted stochastically by needle insertion simulations. HDR procedures were simulated with varying number of needle insertions (4 to 12) using 11 patient MR data-sets with PTV, prostate, urethra, bladder and rectum delineated. Needle positioning errors were modeled by random normally distributed angulation errors (standard deviation of 3 mm at the needle’s tip). The final dose parameters were compared in the situations where the needle with the largest vs. the smallest dose coverage impact was selected at each insertion. Results: Over all scenarios, the percentage of clinically acceptable final dose distribution improved when the needle selected had the largest dose coverage impact (91%) compared to the smallest (88%). The differences were larger for few (4 to 6) needle insertions (maximum difference scenario: 79% vs. 60%). The computation time of the needle sequence optimization was below 60s. Conclusion: A new adaptive needle sequence determination for HDR prostate brachytherapy was developed. Coupled to adaptive planning, the selection of the needle with the largest dose coverage impact increases chances of reaching the clinical constraints. M. Borot de Battisti is funded by Philips Medical Systems Nederland B.V.; M. Moerland is principal investigator on a contract funded by Philips Medical Systems Nederland B.V.; G. Hautvast and D. Binnekamp are fulltime employees of Philips Medical Systems Nederland B.V.« less
Ohuchida, Kenoki; Moriyama, Taiki; Shindo, Koji; Manabe, Tatsuya; Ohtsuka, Takao; Shimizu, Shuji; Nakamura, Masafumi
2017-01-01
Background We previously reported the use of an inverted T-shaped method to obtain a suitable view for hand sewing to close the common entry hole when the linear stapler was fired for esophagojejunostomy after laparoscopic total gastrectomy (LTG). This conventional method involved insertion of the fixed cartridge fork to the Roux limb and the fine movable anvil fork to the esophagus to avoid perforation of the jejunum. However, insertion of the movable anvil fork to the esophagus during this procedure often requires us to strongly push down the main body of the stapler with the fixed cartridge fork to bring the direction of the anvil fork in line with the direction of the long axis of the esophagus while controlling the opening of the movable anvil fork. We therefore modified this complicated inverted T-shaped method using a linear stapler with a movable cartridge fork. This modified method involved insertion of the movable cartridge fork into the Roux limb followed by natural, easy insertion of the fixed anvil fork into the esophagus without controlling the opening of the movable cartridge fork. Methods We performed LTG in a total of 155 consecutive patients with gastric cancer from November 2007 to December 2015 in Kyushu University Hospital. After LTG, we performed the conventional inverted T-shaped method using a linear stapler with a fixed cartridge fork in 61 patients from November 2007 to July 2011 (fixed cartridge group). From August 2011, we used a linear stapler with a movable cartridge fork and performed the modified inverted T-shaped method in 94 patients (movable cartridge group). We herein compare the short-term outcomes in 94 cases of LTG using the modified method (movable cartridge fork) with those in 61 cases using the conventional method (fixed cartridge fork). Results We found no significant differences in the perioperative or postoperative events between the movable and fixed cartridge groups. One case of anastomotic leakage occurred in the fixed cartridge group, but no anastomotic leakage occurred in the movable cartridge group. Conclusions Although there were no remarkable differences in the short-term outcomes between the movable and fixed cartridge groups, we believe that the modified inverted T-shaped method is technically more feasible and reliable than the conventional method and will contribute to the improved safety of LTG. PMID:28616606
Chairside multi-unit restoration of a quadrant using the new Cerec 3D software.
Ender, A; Wiedhahn, K; Mörmann, W H
2003-01-01
The new Cerec 3D design software for inlays and partial and full crowns simplifies work when producing several restorations in one session. Quite significant progress has been achieved, in that the entire row of teeth of a quadrant can be acquired completely and displayed by successively overlapping optical impressions. The digital working model of a quadrant in which all preparations are acquired is the result. The restorations can be designed individually and inserted virtually. Thanks to virtual insertion, the proximal contacts to neighboring restorations can be designed perfectly and all restorations finally designed, milled, and inserted in one sitting. This method provides a significant rationalization effect.
Triple helix purification and sequencing
Wang, Renfeng; Smith, Lloyd M.; Tong, Xinchun E.
1995-01-01
Disclosed herein are methods, kits, and equipment for purifying single stranded circular DNA and then using the DNA for DNA sequencing purposes. Templates are provided with an insert having a hybridization region. An elongated oligonucleotide has two regions that are complementary to the insert and the oligo is bound to a magnetic anchor. The oligo hybridizes to the insert on two sides to form a stable triple helix complex. The anchor can then be used to drag the template out of solution using a magnet. The system can purify sequencing templates, and if desired the triple helix complex can be opened up to a double helix so that the oligonucleotide will act as a primer for further DNA synthesis.
Triple helix purification and sequencing
Wang, R.; Smith, L.M.; Tong, X.E.
1995-03-28
Disclosed herein are methods, kits, and equipment for purifying single stranded circular DNA and then using the DNA for DNA sequencing purposes. Templates are provided with an insert having a hybridization region. An elongated oligonucleotide has two regions that are complementary to the insert and the oligo is bound to a magnetic anchor. The oligo hybridizes to the insert on two sides to form a stable triple helix complex. The anchor can then be used to drag the template out of solution using a magnet. The system can purify sequencing templates, and if desired the triple helix complex can be opened up to a double helix so that the oligonucleotide will act as a primer for further DNA synthesis. 4 figures.
Nie, Xiao-wei; Sun, Li-jun; Hao, Yue-wen; Yang, Guang-xiao; Wang, Quan-ying
2011-03-01
To synthesize the minimal and artificial HRE, and to insert it into the anterior extremity of CMV promoter of a AAV plasmid, and then to construct the AAV regulated by hypoxic-responsive element which was introduced into 293 cell by method of Ca3(PO4)2 using three plasmids. Thus obtaining the adenoassociated virus vector regulated by hypoxic-responsive element was possibly used for gene therapy in ischemia angiocardiopathy and cerebrovascular disease. Artificially synthesize the 36 bp nucleotide sequences of four connection in series HIF-binding sites A/GCGTG(4×HBS)and a 35 bp nucleotide sequences spacing inserted into anterior extremity of CMV promoter TATA Box, then amplified by PCR. The cDNA fragment was confirmed to be right by DNA sequencing. Molecular biology routine method was used to construct a AAV vector regulated by minimal hypoxic-responsive element after the normal CMV promoter in AAV vector was replaced by the CMV promoter included minimal hypoxic-responsive element. Then, NT4-6His-PR39 fusogenic peptide was inserted into MCS of the plasmid, the recombinant AAV vector was obtained by three plasmid co-transfection in 293 cells, in which we can also investigate the expression of 6×His using immunochemistry in hypoxia environment. Artificial HRE was inserted into anterior extremity of CMV promoter and there was a correct spacing between the HRE and the TATA-box. The DNA sequencing and restriction enzyme digestion results indicated that the AAV regulated by hypoxic-responsive element was successfully constructed. Compared to the control group, the expressions of 6×His was significantly increased in the experimental groups in hypoxia environment, which confirmed that the AAV effectually regulated by the minimal HRE was inserted into anterior extremity of CMV promoter. The HRE is inserted into anterior extremity of CMV promoter to lack incision enzyme recognition site by PCR. And eukaryotic expression vector regulated by hypoxic-responsive is constructed. The AAV effectually regulated by the minimal HRE inserted into anterior extremity of CMV promoter. The vector is successfully constructed and it has important theoretical and practical value in the synteresis and therapy of ischemia angiocardiopathy and cerebrovascular disease.
Zhu, Yun J; Fitch, Maureen M M; Moore, Paul H
2006-01-01
Transgenic papaya plants were initially obtained using particle bombardment, a method having poor efficiency in producing intact, single-copy insertion of transgenes. Single-copy gene insertion was improved using Agrobacterium tumefaciens. With progress being made in genome sequencing and gene discovery, there is a need for more efficient methods of transformation in order to study the function of these genes. We describe a protocol for Agrobacterium-mediated transformation using carborundum-wounded papaya embryogenic calli. This method should lead to high-throughput transformation, which on average produced at least one plant that was positive in polymerase chain reaction (PCR), histochemical staining, or by Southern blot hybridization from 10 to 20% of the callus clusters that had been co-cultivated with Agrobacterium. Plants regenerated from the callus clusters in 9 to 13 mo.
Design of microstrip patch antennas using knowledge insertion through retraining
NASA Astrophysics Data System (ADS)
Divakar, T. V. S.; Sudhakar, A.
2018-04-01
The traditional way of analyzing/designing neural network is to collect experimental data and train neural network. Then, the trained neural network acts as global approximate function. The network is then used to calculate parameters for unknown configurations. The main drawback of this method is one does not have enough experimental data, cost of prototypes being a major factor [1-4]. Therefore, in this method the author collected training data from available approximate formulas with in full design range and trained the network with it. After successful training, the network is retrained with available measured results. This simple way inserts experimental knowledge into the network [5]. This method is tested for rectangular microstrip antenna and circular microstrip antenna.
Efficient Mutagenesis Independent of Ligation (EMILI).
Füzik, Tibor; Ulbrich, Pavel; Ruml, Tomáš
2014-11-01
Site-directed mutagenesis is one of the most widely used techniques in life sciences. Here we describe an improved and simplified method for introducing mutations at desired sites. It consists of an inverse PCR using a plasmid template and two partially complementary primers. The synthesis step is followed by annealing of the PCR product's sticky ends, which are generated by exonuclease digestion. This method is fast, extremely efficient and cost-effective. It can be used to introduce large insertions and deletions, but also for multiple point mutations in a single step. To show the principle and to prove the efficiency of the method, we present a series of basic mutations (insertions, deletions, point mutations) on pUC19 plasmid DNA. Copyright © 2014 Elsevier B.V. All rights reserved.
Fusion of electromagnetic trackers to improve needle deflection estimation: simulation study.
Sadjadi, Hossein; Hashtrudi-Zaad, Keyvan; Fichtinger, Gabor
2013-10-01
We present a needle deflection estimation method to anticipate needle bending during insertion into deformable tissue. Using limited additional sensory information, our approach reduces the estimation error caused by uncertainties inherent in the conventional needle deflection estimation methods. We use Kalman filters to combine a kinematic needle deflection model with the position measurements of the base and the tip of the needle taken by electromagnetic (EM) trackers. One EM tracker is installed on the needle base and estimates the needle tip position indirectly using the kinematic needle deflection model. Another EM tracker is installed on the needle tip and estimates the needle tip position through direct, but noisy measurements. Kalman filters are then employed to fuse these two estimates in real time and provide a reliable estimate of the needle tip position, with reduced variance in the estimation error. We implemented this method to compensate for needle deflection during simulated needle insertions and performed sensitivity analysis for various conditions. At an insertion depth of 150 mm, we observed needle tip estimation error reductions in the range of 28% (from 1.8 to 1.3 mm) to 74% (from 4.8 to 1.2 mm), which demonstrates the effectiveness of our method, offering a clinically practical solution.
The latest generation in flexible bronchoscopes: a description and evaluation.
Hsia, David W; Tanner, Nichole T; Shamblin, Clayton; Mehta, Hiren J; Silvestri, Gerard A; Musani, Ali I
2013-10-01
Since the introduction of the flexible bronchoscope over 50 years ago, bronchoscopists have seen vast improvement in the technology available for diagnostics and therapeutics in the bronchoscopy laboratory. We set forth to evaluate the latest evolution in flexible bronchoscopes with features designed to improve imaging and airway navigation. The BF-Q190, BF-H190, and/or BF-1TH190 bronchoscopes were evaluated prospectively in 105 patients undergoing bronchoscopy from November 2010 to August 2011 at 2 tertiary care centers in the United States. Data collected from each procedure included method of insertion, airway images, and therapeutic interventions. At the completion of the study, 10 bronchoscopists were surveyed using a 7-point Likert scale to identify the perceived benefits of the design. Insertion methods included nasal, oral, laryngeal mask airway or endotracheal tube, and tracheostomy. Procedures performed included bronchoalveolar lavage, endobronchial biopsy or brushing, transbronchial biopsy, transbronchial needle aspiration or injection, peripheral navigation, and large airway therapeutic interventions. Survey of bronchoscopists revealed that when compared with current bronchoscopes, the features rated as having the most significant impact on functionality are the 210-degree tip angulation (average 2.4/3) and rotational capability of the insertion tube (average 2.4/3). The new-generation flexible bronchoscope offers improvement in image quality, magnification options, unique insertion tube rotation, and an increased 210-degree distal tip angulation over currently available flexible bronchoscopes. The bronchoscopes are an overall improvement to the current generation of bronchoscopes. The increased tip angulation and novel rotating insertion tube add the most to improvement in functionality.
Ker, Katharine; Tansley, Gavin; Beecher, Deirdre; Perner, Anders; Shakur, Haleema; Harris, Tim; Roberts, Ian
2015-01-01
Background Dehydration is an important cause of death in patients with Ebola virus disease (EVD). Parenteral fluids are often required in patients with fluid requirements in excess of their oral intake. The peripheral intravenous route is the most commonly used method of parenteral access, but inserting and maintaining an intravenous line can be challenging in the context of EVD. Therefore it is important to consider the advantages and disadvantages of different routes for achieving parenteral access (e.g. intravenous, intraosseous, subcutaneous and intraperitoneal). Objectives To compare the reliability, ease of use and speed of insertion of different parenteral access methods. Search methods We ran the search on 17 November 2014. We searched the Cochrane Injuries Group's Specialised Register, Cochrane Central Register of Controlled Trials (CENTRAL, The Cochrane Library), Ovid MEDLINE(R) In-Process & Other Non-Indexed Citations, Ovid MEDLINE(R) Daily, Ovid MEDLINE(R) and Ovid OLDMEDLINE(R), Embase Classic + Embase (OvidSP), CINAHL (EBSCOhost), clinicaltrials.gov and screened reference lists. Selection criteria Randomised controlled trials comparing different parenteral routes for the infusion of fluids or medication. Data collection and analysis Two review authors examined the titles and abstracts of records obtained by searching the electronic databases to determine eligibility. Two review authors extracted data from the included trials and assessed the risk of bias. Outcome measures of interest were success of insertion; time required for insertion; number of insertion attempts; number of dislodgements; time period with functional access; local site reactions; clinicians' perception of ease of administration; needlestick injury to healthcare workers; patients' discomfort; and mortality. For trials involving the administration of fluids we also collected data on the volume of fluid infused, changes in serum electrolytes and markers of renal function. We rated the quality of the evidence as 'high', 'moderate', 'low' or 'very low' according to the GRADE approach for the following outcomes: success of insertion, time required for insertion, number of dislodgements, volume of fluid infused and needlestick injuries. Main results We included 17 trials involving 885 participants. Parenteral access was used to infuse fluids in 11 trials and medications in six trials. None of the trials involved patients with EVD. Intravenous and intraosseous access was compared in four trials; intravenous and subcutaneous access in 11; peripheral intravenous and intraperitoneal access in one; saphenous vein cutdown and intraosseous access in one; and intraperitoneal with subcutaneous access in one. All of the trials assessing the intravenous method involved peripheral intravenous access. We judged few trials to be at low risk of bias for any of the assessed domains. Compared to the intraosseous group, patients in the intravenous group were more likely to experience an insertion failure (risk ratio (RR) 3.89, 95% confidence interval (CI) 2.39 to 6.33; n = 242; GRADE rating: low). We did not pool data for time to insertion but estimates from the trials suggest that inserting intravenous access takes longer (GRADE rating: moderate). Clinicians judged the intravenous route to be easier to insert (RR 0.15, 95% CI 0.04 to 0.61; n = 182). A larger volume of fluids was infused via the intravenous route (GRADE rating: moderate). There was no evidence of a difference between the two routes for any other outcomes, including adverse events. Compared to the subcutaneous group, patients in the intravenous group were more likely to experience an insertion failure (RR 14.79, 95% CI 2.87 to 76.08; n = 238; GRADE rating: moderate) and dislodgement of the device (RR 3.78, 95% CI 1.16 to 12.34; n = 67; GRADE rating: low). Clinicians also judged the intravenous route as being more difficult to insert and patients were more likely to be agitated in the intravenous group. Patients in the intravenous group were more likely to develop a local infection and phlebitis, but were less likely to develop erythema, oedema or swelling than those in the subcutaneous group. A larger volume of fluids was infused into patients via the intravenous route. There was no evidence of a difference between the two routes for any other outcome. There were insufficient data to reliably determine if the risk of insertion failure differed between the saphenous vein cutdown (SVC) and intraosseous method (RR 4.00, 95% CI 0.51 to 31.13; GRADE rating: low). Insertion using SVC took longer than the intraosseous method (MD 219.60 seconds, 95% CI 135.44 to 303.76; GRADE rating: moderate). There were no data and therefore there was no evidence of a difference between the two routes for any other outcome. There were insufficient data to reliably determine the relative effects of intraperitoneal or central intravenous access relative to any other parenteral access method. Authors' conclusions There are several different ways of achieving parenteral access in patients who are unable meet their fluid requirements with oral intake alone. The quality of the evidence, as assessed using the GRADE criteria, is somewhat limited because of the lack of adequately powered trials at low risk of bias. However, we believe that there is sufficient evidence to draw the following conclusions: if peripheral intravenous access can be achieved easily, this allows infusion of larger volumes of fluid than other routes; but if this is not possible, the intraosseous and subcutaneous routes are viable alternatives. The subcutaneous route may be suitable for patients who are not severely dehydrated but in whom ongoing fluid losses cannot be met by oral intake. A film to accompany this review can be viewed here (http://youtu.be/ArVPzkf93ng). PLAIN LANGUAGE SUMMARY Comparison of the different ways of giving fluids to patients who cannot drink enough, such as patients with Ebola virus disease Background Many patients with Ebola virus disease (EVD) die because they are dehydrated. Patients with EVD often experience severe vomiting and diarrhoea, which causes them to lose fluids that are difficult to replace by drinking alone. It is possible to give fluids in ways that do not involve the digestive tract; this is known as parenteral access. This includes infusing fluids into a vein (intravenously), into bone marrow (intraosseously), into fatty tissue under the skin (subcutaneously) or into the abdominal space (intraperitoneally). Giving fluids intravenously is the usual method, but can be problematic in patients with EVD because starting intravenous fluids can be difficult in very dehydrated patients, and infection control practices may make maintaining the infusion challenging. It is therefore useful if those caring for patients with EVD know the advantages and disadvantages of the other ways to give fluids, so that they can decide which is the most suitable for their patients. Searches for trials We carried out searches for trials comparing different parenteral access methods on 17 November 2014. Trial characteristics We found 17 trials involving 885 participants. None involved patients with EVD. Fifteen trials involved patients who required parenteral access for the infusion of fluids or medicines and two trials assessed different methods under simulated conditions, such as on a training manikin. Many trials were of poor quality. Key results When the results of these trials were gathered together, they suggested that both the intraosseous and subcutaneous routes may be easier and quicker to insert into patients than the intravenous route, but more fluid can be given intravenously than by either the intraosseous or subcutaneous method. There has not been enough research into the intraperitoneal method to know how it compares to the other methods. Conclusions Healthcare workers caring for patients with EVD should be aware of the alternative ways of giving fluids. The trials we found were not of very high quality, therefore we need to be cautious when drawing conclusions based on their results. However, together they suggest if intravenous access can be achieved easily, then this should be used as it allows the infusion of larger volumes of fluid. However, if intravenous access is not possible, intraosseous and subcutaneous routes are alternatives that can be inserted quickly. Many of the trials conducted so far are of poor quality and none involved patients with EVD, therefore more trials should be carried out. A film to accompany this review can be viewed here. PMID:25914907
2009-01-01
Background Insertional mutagenesis is an effective method for functional genomic studies in various organisms. It can rapidly generate easily tractable mutations. A large-scale insertional mutagenesis with the piggyBac (PB) transposon is currently performed in mice at the Institute of Developmental Biology and Molecular Medicine (IDM), Fudan University in Shanghai, China. This project is carried out via collaborations among multiple groups overseeing interconnected experimental steps and generates a large volume of experimental data continuously. Therefore, the project calls for an efficient database system for recording, management, statistical analysis, and information exchange. Results This paper presents a database application called MP-PBmice (insertional mutation mapping system of PB Mutagenesis Information Center), which is developed to serve the on-going large-scale PB insertional mutagenesis project. A lightweight enterprise-level development framework Struts-Spring-Hibernate is used here to ensure constructive and flexible support to the application. The MP-PBmice database system has three major features: strict access-control, efficient workflow control, and good expandability. It supports the collaboration among different groups that enter data and exchange information on daily basis, and is capable of providing real time progress reports for the whole project. MP-PBmice can be easily adapted for other large-scale insertional mutation mapping projects and the source code of this software is freely available at http://www.idmshanghai.cn/PBmice. Conclusion MP-PBmice is a web-based application for large-scale insertional mutation mapping onto the mouse genome, implemented with the widely used framework Struts-Spring-Hibernate. This system is already in use by the on-going genome-wide PB insertional mutation mapping project at IDM, Fudan University. PMID:19958505
De Boo, Diederick W; Mott, Nigel; Tregaskis, Peter; Quach, Trung; Menahem, Solomon; Walker, Rowan G; Koukounaras, Jim
2015-12-01
Various methods of peritoneal dialysis (PD) catheter insertion are available. The purpose of this study was to evaluate a percutaneous insertion technique using ultrasound (US) and fluoroscopy performed under conscious sedation and as day case procedure. Data of 87 percutaneous inserted dialysis catheters were prospectively collected, including patients' age, gender, body mass index, history of previous abdominal surgery and cause of end stage renal failure. Length of hospital stay, early complications and time to first use were also recorded. Institutional review board approval was obtained. A 100% technical success rate was observed. Early complications included bleeding (n = 3), catheter dysfunction (n = 6), exit site infection (n = 1) and exit site leakage (n = 1). All cases of catheter dysfunction and one case of bleeding required surgical revision. Median time of follow-up was 18 months (range 3-35), and median time from insertion to first use was days 14 (1-47). Of the 82 patients who started dialysis, 20 (23%) ceased PD at some stage during follow-up. Most frequently encountered reasons include deteriorating patient cognitive or functional status (n = 5), successful transplant kidney (n = 4) and pleuro-peritoneal fistula (n = 4). Sixty-two (71%) PD catheter insertions were performed as day case. The remaining insertions were performed on patients already admitted to the hospital. Percutaneous insertion of dialysis catheter using US and fluoroscopy is not only safe but can be performed as day case procedure in most patients, even with a medical history of abdominal surgery and/or obesity. © 2015 The Royal Australian and New Zealand College of Radiologists.
[Reducing the Incidence of Phlebitis Related to Intravenous Injection in Pediatric Patients].
Cho, Yen-Hua; Yen, Li-Ling; Yu, Kai-Ling; Chang, Chun-Chu; Chen, Hsuen-Ling
2015-06-01
Peripheral venous catheter (PVC) is commonly used to provide nutrition and medicine to pediatric inpatients. Phlebitis is a common side effect of PVC insertion. Over 90% of pediatric patients in the paedi-atric medical ward at the Chang Gung Memorial Hospital (CGMH) receive PVC insertion, with an incident rate of phlebitis of 5.07%. Common cause factors of phlebitis are: insufficient sterilization time, inappropriate methods used to fix the PVC, the use of fixtures that loosen easily, high re-fix rates, and inadequate wound care after catheter removal. The purpose of this project was to reduce the incidence rate of PVC-insertion-related phlebitis in children from 5.07% to 2.5%. A one-week clinical observation identified the re-inserting / re-fixing of existing PVCs as the principal cause of phlebitis in the CGMH paediatric ward. Therefore, the researchers modified the catheter care bundle based on a review of the literature and the suggestions of clinical pediatric experts. Modifications included applying 2% chlorhexidine to sterilize the insertion site; using a new, non-woven fabric splint to fix the PVC site; providing cartoon-themed waterproof dressings for the first bath after the removal of the PVC; and setting standard operating procedures (SOPs) for PVC insertion and catheter removal. After applying these modifications, the incident rate of phlebitis in children with PVC insertions decreased from 5.07% to 2.08%. The application of 2% chlorhexidine reduces the waiting time for sterilization; the purpose-designed splint strengthens the fixation of the PVC; and the development of the SOPs for PVC insertion and post-removal catheter care reduces the risk of phlebitis. The combination of these strategies effectively reduces the incidence of phlebitis and improves the nursing care quality.
Rest Intervals Reduce the Number of Loading Bouts Required to Enhance Bone Formation
Srinivasan, Sundar; Ausk, Brandon J.; Bain, Steven D.; Gardiner, Edith M.; Kwon, Ronald Y.; Gross, Ted S.
2015-01-01
Purpose As our society becomes increasingly sedentary, compliance with exercise regimens that require numerous high-energy activities each week become less likely. Alternatively, given an osteogenic exercise intervention that required minimal effort, it is reasonable to presume that participation would be enhanced. Insertion of brief rest-intervals between each cycle of mechanical loading holds potential to achieve this result as substantial osteoblast function is activated by many fewer loading repetitions within each loading bout. Here, we examined the complementary hypothesis that the number of bouts/wk of rest-inserted loading could be reduced from 3/wk without loss of osteogenic efficacy. Methods We conducted a series of 3 wk in vivo experiments that non-invasively exposed the right tibiae of mice to either cyclic (1 Hz) or rest-inserted loading interventions and quantified osteoblast function via dynamic histomorphometry. Results While reducing loading bouts from 3/wk (i.e., 9 total bouts) to 1/wk (3 total bouts) effectively mitigated the osteogenic benefit of cyclic loading, the same reduction did not significantly reduce periosteal bone formation parameters induced by rest-inserted loading. The osteogenic response was robust to the timing of the rest-inserted loading bouts (3 bouts in the first week vs 1 bout/wk for three weeks). However, elimination of any single bout of the three 1/wk bouts mitigated the osteogenic response to rest-inserted loading. Finally, periosteal osteoblast function assessed after the 3 wk intervention was not sensitive to the timing or number of rest-inserted loading bouts. Conclusions We conclude that rest-inserted loading holds potential to retain the osteogenic benefits of mechanical loading with significantly reduced frequency of bouts of activity while also enabling greater flexibility in the timing of the activity. PMID:25207932
Easi-CRISPR for creating knock-in and conditional knockout mouse models using long ssDNA donors.
Miura, Hiromi; Quadros, Rolen M; Gurumurthy, Channabasavaiah B; Ohtsuka, Masato
2018-01-01
CRISPR/Cas9-based genome editing can easily generate knockout mouse models by disrupting the gene sequence, but its efficiency for creating models that require either insertion of exogenous DNA (knock-in) or replacement of genomic segments is very poor. The majority of mouse models used in research involve knock-in (reporters or recombinases) or gene replacement (e.g., conditional knockout alleles containing exons flanked by LoxP sites). A few methods for creating such models have been reported that use double-stranded DNA as donors, but their efficiency is typically 1-10% and therefore not suitable for routine use. We recently demonstrated that long single-stranded DNAs (ssDNAs) serve as very efficient donors, both for insertion and for gene replacement. We call this method efficient additions with ssDNA inserts-CRISPR (Easi-CRISPR) because it is a highly efficient technology (efficiency is typically 30-60% and reaches as high as 100% in some cases). The protocol takes ∼2 months to generate the founder mice.
Computerized tomography calibrator
NASA Technical Reports Server (NTRS)
Engel, Herbert P. (Inventor)
1991-01-01
A set of interchangeable pieces comprising a computerized tomography calibrator, and a method of use thereof, permits focusing of a computerized tomographic (CT) system. The interchangeable pieces include a plurality of nestable, generally planar mother rings, adapted for the receipt of planar inserts of predetermined sizes, and of predetermined material densities. The inserts further define openings therein for receipt of plural sub-inserts. All pieces are of known sizes and densities, permitting the assembling of different configurations of materials of known sizes and combinations of densities, for calibration (i.e., focusing) of a computerized tomographic system through variation of operating variables thereof. Rather than serving as a phanton, which is intended to be representative of a particular workpiece to be tested, the set of interchangeable pieces permits simple and easy standardized calibration of a CT system. The calibrator and its related method of use further includes use of air or of particular fluids for filling various openings, as part of a selected configuration of the set of pieces.
Phylogenetic Placement of Exact Amplicon Sequences Improves Associations with Clinical Information
McDonald, Daniel; Gonzalez, Antonio; Navas-Molina, Jose A.; Jiang, Lingjing; Xu, Zhenjiang Zech; Winker, Kevin; Kado, Deborah M.; Orwoll, Eric; Manary, Mark; Mirarab, Siavash
2018-01-01
ABSTRACT Recent algorithmic advances in amplicon-based microbiome studies enable the inference of exact amplicon sequence fragments. These new methods enable the investigation of sub-operational taxonomic units (sOTU) by removing erroneous sequences. However, short (e.g., 150-nucleotide [nt]) DNA sequence fragments do not contain sufficient phylogenetic signal to reproduce a reasonable tree, introducing a barrier in the utilization of critical phylogenetically aware metrics such as Faith’s PD or UniFrac. Although fragment insertion methods do exist, those methods have not been tested for sOTUs from high-throughput amplicon studies in insertions against a broad reference phylogeny. We benchmarked the SATé-enabled phylogenetic placement (SEPP) technique explicitly against 16S V4 sequence fragments and showed that it outperforms the conceptually problematic but often-used practice of reconstructing de novo phylogenies. In addition, we provide a BSD-licensed QIIME2 plugin (https://github.com/biocore/q2-fragment-insertion) for SEPP and integration into the microbial study management platform QIITA. IMPORTANCE The move from OTU-based to sOTU-based analysis, while providing additional resolution, also introduces computational challenges. We demonstrate that one popular method of dealing with sOTUs (building a de novo tree from the short sequences) can provide incorrect results in human gut metagenomic studies and show that phylogenetic placement of the new sequences with SEPP resolves this problem while also yielding other benefits over existing methods. PMID:29719869
The loss-of-allele assay for ES cell screening and mouse genotyping.
Frendewey, David; Chernomorsky, Rostislav; Esau, Lakeisha; Om, Jinsop; Xue, Yingzi; Murphy, Andrew J; Yancopoulos, George D; Valenzuela, David M
2010-01-01
Targeting vectors used to create directed mutations in mouse embryonic stem (ES) cells consist, in their simplest form, of a gene for drug selection flanked by mouse genomic sequences, the so-called homology arms that promote site-directed homologous recombination between the vector and the target gene. The VelociGene method for the creation of targeted mutations in ES cells employs targeting vectors, called BACVecs, that are based on bacterial artificial chromosomes. Compared with conventional short targeting vectors, BacVecs provide two major advantages: (1) their much larger homology arms promote high targeting efficiencies without the need for isogenicity or negative selection strategies; and (2) they enable deletions and insertions of up to 100kb in a single targeting event, making possible gene-ablating definitive null alleles and other large-scale genomic modifications. Because of their large arm sizes, however, BACVecs do not permit screening by conventional assays, such as long-range PCR or Southern blotting, that link the inserted targeting vector to the targeted locus. To exploit the advantages of BACVecs for gene targeting, we inverted the conventional screening logic in developing the loss-of-allele (LOA) assay, which quantifies the number of copies of the native locus to which the mutation was directed. In a correctly targeted ES cell clone, the LOA assay detects one of the two native alleles (for genes not on the X or Y chromosome), the other allele being disrupted by the targeted modification. We apply the same principle in reverse as a gain-of-allele assay to quantify the copy number of the inserted targeting vector. The LOA assay reveals a correctly targeted clone as having lost one copy of the native target gene and gained one copy of the drug resistance gene or other inserted marker. The combination of these quantitative assays makes LOA genotyping unequivocal and amenable to automated scoring. We use the quantitative polymerase chain reaction (qPCR) as our method of allele quantification, but any method that can reliably distinguish the difference between one and two copies of the target gene can be used to develop an LOA assay. We have designed qPCR LOA assays for deletions, insertions, point mutations, domain swaps, conditional, and humanized alleles and have used the insert assays to quantify the copy number of random insertion BAC transgenics. Because of its quantitative precision, specificity, and compatibility with high throughput robotic operations, the LOA assay eliminates bottlenecks in ES cell screening and mouse genotyping and facilitates maximal speed and throughput for knockout mouse production. Copyright (c) 2010 Elsevier Inc. All rights reserved.
Chen, Chao; Zhao, Xinqing; Jin, Yingyu; Zhao, Zongbao Kent; Suh, Joo-Won
2014-11-01
Bacterial artificial chromosomal (BAC) vectors are increasingly being used in cloning large DNA fragments containing complex biosynthetic pathways to facilitate heterologous production of microbial metabolites for drug development. To express inserted genes using Streptomyces species as the production hosts, an integration expression cassette is required to be inserted into the BAC vector, which includes genetic elements encoding a phage-specific attachment site, an integrase, an origin of transfer, a selection marker and a promoter. Due to the large sizes of DNA inserted into the BAC vectors, it is normally inefficient and time-consuming to assemble these fragments by routine PCR amplifications and restriction-ligations. Here we present a rapid method to insert fragments to construct BAC-based expression vectors. A DNA fragment of about 130 bp was designed, which contains upstream and downstream homologous sequences of both BAC vector and pIB139 plasmid carrying the whole integration expression cassette. In-Fusion cloning was performed using the designer DNA fragment to modify pIB139, followed by λ-RED-mediated recombination to obtain the BAC-based expression vector. We demonstrated the effectiveness of this method by rapid construction of a BAC-based expression vector with an insert of about 120 kb that contains the entire gene cluster for biosynthesis of immunosuppressant FK506. The empty BAC-based expression vector constructed in this study can be conveniently used for construction of BAC libraries using either microbial pure culture or environmental DNA, and the selected BAC clones can be directly used for heterologous expression. Alternatively, if a BAC library has already been constructed using a commercial BAC vector, the selected BAC vectors can be manipulated using the method described here to get the BAC-based expression vectors with desired gene clusters for heterologous expression. The rapid construction of a BAC-based expression vector facilitates heterologous expression of large gene clusters for drug discovery. Copyright © 2014 Elsevier Inc. All rights reserved.
Ohuchida, Kenoki; Nagai, Eishi; Moriyama, Taiki; Shindo, Koji; Manabe, Tatsuya; Ohtsuka, Takao; Shimizu, Shuji; Nakamura, Masafumi
2017-01-01
We previously reported the use of an inverted T-shaped method to obtain a suitable view for hand sewing to close the common entry hole when the linear stapler was fired for esophagojejunostomy after laparoscopic total gastrectomy (LTG). This conventional method involved insertion of the fixed cartridge fork to the Roux limb and the fine movable anvil fork to the esophagus to avoid perforation of the jejunum. However, insertion of the movable anvil fork to the esophagus during this procedure often requires us to strongly push down the main body of the stapler with the fixed cartridge fork to bring the direction of the anvil fork in line with the direction of the long axis of the esophagus while controlling the opening of the movable anvil fork. We therefore modified this complicated inverted T-shaped method using a linear stapler with a movable cartridge fork. This modified method involved insertion of the movable cartridge fork into the Roux limb followed by natural, easy insertion of the fixed anvil fork into the esophagus without controlling the opening of the movable cartridge fork. We performed LTG in a total of 155 consecutive patients with gastric cancer from November 2007 to December 2015 in Kyushu University Hospital. After LTG, we performed the conventional inverted T-shaped method using a linear stapler with a fixed cartridge fork in 61 patients from November 2007 to July 2011 (fixed cartridge group). From August 2011, we used a linear stapler with a movable cartridge fork and performed the modified inverted T-shaped method in 94 patients (movable cartridge group). We herein compare the short-term outcomes in 94 cases of LTG using the modified method (movable cartridge fork) with those in 61 cases using the conventional method (fixed cartridge fork). We found no significant differences in the perioperative or postoperative events between the movable and fixed cartridge groups. One case of anastomotic leakage occurred in the fixed cartridge group, but no anastomotic leakage occurred in the movable cartridge group. Although there were no remarkable differences in the short-term outcomes between the movable and fixed cartridge groups, we believe that the modified inverted T-shaped method is technically more feasible and reliable than the conventional method and will contribute to the improved safety of LTG.
NASA Astrophysics Data System (ADS)
Borot de Battisti, M.; de Senneville, B. Denis; Hautvast, G.; Binnekamp, D.; Lagendijk, J. J. W.; Maenhout, M.; Moerland, M. A.
2017-05-01
MR-guided high-dose-rate (HDR) brachytherapy has gained increasing interest as a treatment for patients with localized prostate cancer because of the superior value of MRI for tumor and surrounding tissues localization. To enable needle insertion into the prostate with the patient in the MR bore, a single needle MR-compatible robotic system involving needle-by-needle dose delivery has been developed at our institution. Throughout the intervention, dose delivery may be impaired by: (1) sub-optimal needle positioning caused by e.g. needle bending, (2) intra-operative internal organ motion such as prostate rotations or swelling, or intra-procedural rectum or bladder filling. This may result in failure to reach clinical constraints. To assess the first aforementioned challenge, a recent study from our research group demonstrated that the deposited dose may be greatly improved by real-time adaptive planning with feedback on the actual needle positioning. However, the needle insertion sequence is left to the doctor and therefore, this may result in sub-optimal dose delivery. In this manuscript, a new method is proposed to determine and update automatically the needle insertion sequence. This strategy is based on the determination of the most sensitive needle track. The sensitivity of a needle track is defined as its impact on the dose distribution in case of sub-optimal positioning. A stochastic criterion is thus presented to determine each needle track sensitivity based on needle insertion simulations. To assess the proposed sequencing strategy, HDR prostate brachytherapy was simulated on 11 patients with varying number of needle insertions. Sub-optimal needle positioning was simulated at each insertion (modeled by typical random angulation errors). In 91% of the scenarios, the dose distribution improved when the needle was inserted into the most compared to the least sensitive needle track. The computation time for sequencing was less than 6 s per needle track. The proposed needle insertion sequencing can therefore assist in delivering an optimal dose in HDR prostate brachytherapy.
Liu, Shaoli; Xia, Zeyang; Liu, Jianhua; Xu, Jing; Ren, He; Lu, Tong; Yang, Xiangdong
2016-01-01
The “robotic-assisted liver tumor coagulation therapy” (RALTCT) system is a promising candidate for large liver tumor treatment in terms of accuracy and speed. A prerequisite for effective therapy is accurate surgical planning. However, it is difficult for the surgeon to perform surgical planning manually due to the difficulties associated with robot-assisted large liver tumor therapy. These main difficulties include the following aspects: (1) multiple needles are needed to destroy the entire tumor, (2) the insertion trajectories of the needles should avoid the ribs, blood vessels, and other tissues and organs in the abdominal cavity, (3) the placement of multiple needles should avoid interference with each other, (4) an inserted needle will cause some deformation of liver, which will result in changes in subsequently inserted needles’ operating environment, and (5) the multiple needle-insertion trajectories should be consistent with the needle-driven robot’s movement characteristics. Thus, an effective multiple-needle surgical planning procedure is needed. To overcome these problems, we present an automatic multiple-needle surgical planning of optimal insertion trajectories to the targets, based on a mathematical description of all relevant structure surfaces. The method determines the analytical expression of boundaries of every needle “collision-free reachable workspace” (CFRW), which are the feasible insertion zones based on several constraints. Then, the optimal needle insertion trajectory within the optimization criteria will be chosen in the needle CFRW automatically. Also, the results can be visualized with our navigation system. In the simulation experiment, three needle-insertion trajectories were obtained successfully. In the in vitro experiment, the robot successfully achieved insertion of multiple needles. The proposed automatic multiple-needle surgical planning can improve the efficiency and safety of robot-assisted large liver tumor therapy, significantly reduce the surgeon’s workload, and is especially helpful for an inexperienced surgeon. The methodology should be easy to adapt in other body parts. PMID:26982341
Lester, Felicia; Kakaire, Othman; Byamugisha, Josaphat; Averbach, Sarah; Fortin, Jennifer; Maurer, Rie; Goldberg, Alisa
2015-03-01
To compare rates of Copper T380A intrauterine device (IUD) utilization and satisfaction with immediate versus delayed IUD insertion after cesarean delivery in Kampala, Uganda. This study was a randomized clinical trial of women undergoing cesarean section who desired an IUD in Kampala, Uganda. Participants were randomly assigned to IUD insertion at the time of cesarean delivery or 6weeks afterward. The primary outcome was IUD utilization at 6months after delivery. Among 68 women who underwent randomization, an IUD was inserted in 100% (34/34) of the women in the immediate insertion group and in 53% (18/34) in the delayed group. IUD use at 6 months was higher in the immediate insertion group (93% vs. 50% after delayed insertion; p<.0001). Infection and expulsion were rare and did not differ between groups. When we pooled both groups and looked at IUD users compared to nonusers, 91% (39/43) of IUD users were satisfied or very satisfied with their contraceptive method compared to 44% (11/25) of nonusers (p<.0001). Women who chose not to be in the study or had the IUD removed often did so because of perceived husband or community disapproval. The 6-month utilization of an IUD after immediate insertion was significantly higher than after delayed insertion without increased complications. Contraceptive satisfaction was significantly higher among IUD users than nonusers. Community and husband attitudes influence IUD utilization and continuation in Kampala, Uganda. This work is important because it shows the safety and efficacy of providing IUDs during cesarean section in a setting where access to any healthcare, including contraception, can be extremely limited outside of childbearing and the consequences of an unintended, closely spaced pregnancy after a cesarean section can be life threatening. Copyright © 2015 Elsevier Inc. All rights reserved.
de Souza, Marco Aurélio Martins; Geber, Selmo
2006-02-01
An intrauterine device (IUD) is one of the most frequently used methods of birth control around the world. Although a relationship between its use and menstrual disorders has been well documented, only a few studies have tried to show whether there are any vascular modifications. The aim of our study was to evaluate the influence of an IUD on uterine artery blood flow using Doppler assessment. A total of 100 patients selected for IUD use were prospectively evaluated with Doppler analysis before and 30 days after insertion. The resistive index (RI) and pulsatility index (PI) were used to evaluate uterine artery vascular resistance. Patients were allocated in 2 groups according to whether they were (group 2) or were not (group 1) lactating. The PI and RI of the patients in groups 1 and 2 before and after IUD insertion were not statistically significantly different (P = .298 and .23). When we compared uterine artery blood flow indices before and after IUD insertion for groups 1 and 2 separately, we observed in group 1 that the mean +/- SD PI values were 2.45 +/- 0.62 and 2.55 +/- 0.55 (P = .38) and the RI values were 0.87 +/- 0.08 and 0.87 +/- 0.06 (P = .88) before and after IUD insertion, respectively. In group 2, the PI values were 2.31 +/- 0.55 and 2.37 +/- 0.69 (P = .68) and the RI values were 0.85 +/- 0.07 and 0.86 +/- 0.07 (P = .44) before and after IUD insertion. Finally, we used the mean blood flow indices of the uterine arteries of all patients to compare the effect of IUD insertion. Results were also not statistically significant when we compared PI and RI before and after IUD insertion. The presence of an IUD does not interfere with the vascular resistance of the uterine arteries that can be shown by Doppler flow assessments 1 month after insertion.
42 CFR 414.313 - Initial method of payment.
Code of Federal Regulations, 2012 CFR
2012-10-01
...) Administration of hepatitis B vaccine. (c) Physician election of the initial method. (1) Each physician in a... examinations to review health status and treatment. (ii) Physician surgical services other than insertion of...
42 CFR 414.313 - Initial method of payment.
Code of Federal Regulations, 2014 CFR
2014-10-01
...) Administration of hepatitis B vaccine. (c) Physician election of the initial method. (1) Each physician in a... examinations to review health status and treatment. (ii) Physician surgical services other than insertion of...
Mobile element biology – new possibilities with high-throughput sequencing
Xing, Jinchuan; Witherspoon, David J.; Jorde, Lynn B.
2014-01-01
Mobile elements compose more than half of the human genome, but until recently their large-scale detection was time-consuming and challenging. With the development of new high-throughput sequencing technologies, the complete spectrum of mobile element variation in humans can now be identified and analyzed. Thousands of new mobile element insertions have been discovered, yielding new insights into mobile element biology, evolution, and genomic variation. We review several high-throughput methods, with an emphasis on techniques that specifically target mobile element insertions in humans, and we highlight recent applications of these methods in evolutionary studies and in the analysis of somatic alterations in human cancers. PMID:23312846
Method and device for supporting blood vessels during anastomosis
Doss, J.D.
1985-05-20
A device and method for preventing first and second severed blood vessels from collapsing during attachment to each other. The device comprises a dissolvable non-toxic stent that is sufficiently rigid to prevent the blood vessels from collapsing during anastomosis. The stent can be hollow or have passages to permit blood flow before it dissolves. A single stent can be inserted with an end in each of the two blood vessels or separate stents can be inserted into each blood vessel. The stent may include a therapeutically effective amount of a drug which is slowly released into the blood stream as the stent dissolves. 12 figs.
Automated location detection of injection site for preclinical stereotactic neurosurgery procedure
NASA Astrophysics Data System (ADS)
Abbaszadeh, Shiva; Wu, Hemmings C. H.
2017-03-01
Currently, during stereotactic neurosurgery procedures, the manual task of locating the proper area for needle insertion or implantation of electrode/cannula/optic fiber can be time consuming. The requirement of the task is to quickly and accurately find the location for insertion. In this study we investigate an automated method to locate the entry point of region of interest. This method leverages a digital image capture system, pattern recognition, and motorized stages. Template matching of known anatomical identifiable regions is used to find regions of interest (e.g. Bregma) in rodents. For our initial study, we tackle the problem of automatically detecting the entry point.
Toyama, H; Anthony, C; Lidstrom, M E
1998-09-01
Methylobacterium extorquens AM1 is a pink-pigmented facultative methylotroph which is widely used for analyzing pathways of C1 metabolism with biochemical and molecular biological techniques. To facilitate this approach, we have applied a new method to construct insertion or disruption mutants with drug resistance genes by electroporation. By using this method, mutants were obtained in four genes present in the mxa methylotrophy gene cluster for which the functions were unknown, mxaR, mxaS, mxaC and mxaD. These mutants were unable to grow on methanol except the mutant of mxaD, which showed reduced growth on methanol.
Task analysis method for procedural training curriculum development.
Riggle, Jakeb D; Wadman, Michael C; McCrory, Bernadette; Lowndes, Bethany R; Heald, Elizabeth A; Carstens, Patricia K; Hallbeck, M Susan
2014-06-01
A central venous catheter (CVC) is an important medical tool used in critical care and emergent situations. Integral to proper care in many circumstances, insertion of a CVC introduces the risk of central line-associated blood stream infections and mechanical adverse events; proper training is important for safe CVC insertion. Cognitive task analysis (CTA) methods have been successfully implemented in the medical field to improve the training of postgraduate medical trainees, but can be very time-consuming to complete and require a significant time commitment from many subject matter experts (SMEs). Many medical procedures such as CVC insertion are linear processes with well-documented procedural steps. These linear procedures may not require a traditional CTA to gather the information necessary to create a training curriculum. Accordingly, a novel, streamlined CTA method designed primarily to collect cognitive cues for linear procedures was developed to be used by medical professionals with minimal CTA training. This new CTA methodology required fewer trained personnel, fewer interview sessions, and less time commitment from SMEs than a traditional CTA. Based on this study, a streamlined CTA methodology can be used to efficiently gather cognitive information on linear medical procedures for the creation of resident training curricula and procedural skills assessments.
Limited Uptake of Planned Intrauterine Devices During the Postpartum Period.
Salcedo, Jennifer; Moniaga, Natalie; Harken, Tabetha
2015-08-01
The primary objective of this study was to determine the percentage of women with a documented plan for postpartum intrauterine device (IUD) insertion who had a device inserted within 8 weeks of delivery. The secondary objective was to determine factors associated with successful initiation of postpartum IUDs as planned. We conducted a retrospective chart review of women who had at least one prenatal visit and delivered a viable pregnancy at our academic medical center. Methods of planned and established postpartum contraceptive methods were recorded, as well as demographic information and documented reasons for failure to initiate planned intrauterine contraception. A total of 110 women planned postpartum IUD placement. Of these women, 84 (76%) presented for at least one postpartum appointment. Only 22.6% (95% confidence interval 13.7-31.5) of those presenting for postpartum follow-up underwent IUD placement within 8 weeks of delivery. Women planning postpartum IUD insertion were just as likely as women with no planned postpartum contraceptive method to fail to establish contraception within 8 weeks (P = 0.55). Failure to establish planned postpartum intrauterine contraception occurs frequently, even in a setting with a high rate of postpartum follow-up.
Assessment of shock wave lithotripters via cavitation potential
Iloreta, Jonathan I.; Zhou, Yufeng; Sankin, Georgy N.; Zhong, Pei; Szeri, Andrew J.
2008-01-01
A method to characterize shock wave lithotripters by examining the potential for cavitation associated with the lithotripter shock wave (LSW) has been developed. The method uses the maximum radius achieved by a bubble subjected to a LSW as a representation of the cavitation potential for that region in the lithotripter. It is found that the maximum radius is determined by the work done on a bubble by the LSW. The method is used to characterize two reflectors: an ellipsoidal reflector and an ellipsoidal reflector with an insert. The results show that the use of an insert reduced the −6 dB volume (with respect to peak positive pressure) from 1.6 to 0.4 cm3, the −6 dB volume (with respect to peak negative pressure) from 14.5 to 8.3 cm3, and reduced the volume characterized by high cavitation potential (i.e., regions characterized by bubbles with radii larger than 429 µm) from 103 to 26 cm3. Thus, the insert is an effective way to localize the potentially damaging effects of shock wave lithotripsy, and suggests an approach to optimize the shape of the reflector. PMID:19865493
Horng, Huann-Cheng; Yuan, Chiou-Chung; Chao, Kuan-Chong; Cheng, Ming-Huei; Wang, Peng-Hui
2007-06-01
To evaluate the efficacy and acceptability of the Port-A-Cath (PAC) insertion method with (conventional group as II) and without (modified group as I) the aid of intraoperative fluoroscopy or other localizing devices. A total of 158 women with various kinds of gynecological cancers warranting PAC insertion (n = 86 in group I and n = 72 in group II, respectively) were evaluated. Data for analyses included patient age, main disease, dislocation site, surgical time, complications, and catheter outcome. There was no statistical difference between the two groups in terms of age, main disease, complications, and the experiencing of patent catheters. However, appropriate positioning (100% in group I, and 82% in group II) in the superior vena cava (SVC) showed statistical differences between the two groups (P = 0.001). In addition, the surgical time in group I was statistically shorter than that in group II (P < 0.001). The modified method for inserting the PAC offered the following benefits: including avoiding X-ray exposure for both the operator and the patient, defining the appropriate position in the SVC, and less surgical time. (c) 2007 Wiley-Liss, Inc.
In vitro and in vivo mechanical stability of orthodontic mini-implants.
Cho, Il-Sik; Kim, Sung-Kyun; Chang, Young-Il; Baek, Seung-Hak
2012-07-01
To compare in vivo and in vitro mechanical stability of orthodontic mini-implants (OMIs) treated with a sandblasted, large-grit, and anodic-oxidation (SLAO) method vs those treated with a sandblasted, large-grit, and acid-etching (SLA) method. Fifty-four titanium OMIs (cylindrical shape, drill-free type; diameter = 1.45 mm, length = 8 mm, Biomaterials Korea Inc, Seoul, Korea) were allocated into control, SLA, and SLAO groups (N = 12 for in vivo and N = 6 for in vitro studies per group). In vitro study was carried out on a polyurethane foam bone block (Sawbones, Pacific Research Laboratories Inc, Vashon, Wash). In vivo study was performed in the tibias of Beagles (6 males, age = 1 year, weight = 10 to 13 kg; OMIs were removed at 8 weeks after installation). For insertion and removal of OMIs, the speed and maximum torque of the surgical engine were set to 30 rpm and 40 Ncm, respectively. Maximum torque (MT), total energy (TE), and near peak energy (NPE) during the insertion and removal procedures were statistically analyzed. In the in vitro study, although the control group had a higher insertion MT value than the SLA and SLAO groups (P < .01), no differences in insertion TE and NPE or in any of the removal variables were noted among the three groups. In the in vivo study, the control group exhibited higher values for all insertion variables compared with the SLA and SLAO groups (MT, P < .001; TE, P < .01; NPE, P < .001). Although no difference in removal TE and removal NPE was noted among the three groups, the SLAO group presented with a higher removal MT than the SLA and control groups (P < .001). SLAO treatment may be an effective tool in reducing insertion damage to surrounding tissue and improving the mechanical stability of OMIs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stromberg, Loreen R.; Hengartner, Nicolas W.; Swingle, Kirstie L.
Shiga toxin-producing Escherichia coli is an important cause of foodborne illness, with cases attributable to beef, fresh produce and other sources. Many serotypes of the pathogen cause disease, and differentiating one serotype from another requires specific identification of the O antigen located on the lipopolysaccharide (LPS) molecule. The amphiphilic structure of LPS poses a challenge when using classical detection methods, which do not take into account its lipoglycan biochemistry. Typically, detection of LPS requires heat or chemical treatment of samples and relies on bioactivity assays for the conserved lipid A portion of the molecule. Our goal was to develop assaysmore » to facilitate the direct and discriminative detection of the entire LPS molecule and its O antigen in complex matrices using minimal sample processing. To perform serogroup identification of LPS, we used a method called membrane insertion on a waveguide biosensor, and tested three serogroups of LPS. The membrane insertion technique allows for the hydrophobic association of LPS with a lipid bilayer, where the exposed O antigen can be targeted for specific detection. Samples of beef lysate were spiked with LPS to perform O antigen specific detection of LPS from E. coli O157. To validate assay performance, we evaluated the biophysical interactions of LPS with lipid bilayers both in- and outside of a flow cell using fluorescence microscopy and fluorescently doped lipids. Our results indicate that membrane insertion allows for the qualitative and reliable identification of amphiphilic LPS in complex samples like beef homogenates. In addition, we also demonstrated that LPS-induced hole formation does not occur under the conditions of the membrane insertion assays. Together, these findings describe for the first time the serogroup-specific detection of amphiphilic LPS in complex samples using a membrane insertion assay, and highlight the importance of LPS molecular conformations in detection architectures.« less
Stromberg, Loreen R.; Hengartner, Nicolas W.; Swingle, Kirstie L.; ...
2016-05-26
Shiga toxin-producing Escherichia coli is an important cause of foodborne illness, with cases attributable to beef, fresh produce and other sources. Many serotypes of the pathogen cause disease, and differentiating one serotype from another requires specific identification of the O antigen located on the lipopolysaccharide (LPS) molecule. The amphiphilic structure of LPS poses a challenge when using classical detection methods, which do not take into account its lipoglycan biochemistry. Typically, detection of LPS requires heat or chemical treatment of samples and relies on bioactivity assays for the conserved lipid A portion of the molecule. Our goal was to develop assaysmore » to facilitate the direct and discriminative detection of the entire LPS molecule and its O antigen in complex matrices using minimal sample processing. To perform serogroup identification of LPS, we used a method called membrane insertion on a waveguide biosensor, and tested three serogroups of LPS. The membrane insertion technique allows for the hydrophobic association of LPS with a lipid bilayer, where the exposed O antigen can be targeted for specific detection. Samples of beef lysate were spiked with LPS to perform O antigen specific detection of LPS from E. coli O157. To validate assay performance, we evaluated the biophysical interactions of LPS with lipid bilayers both in- and outside of a flow cell using fluorescence microscopy and fluorescently doped lipids. Our results indicate that membrane insertion allows for the qualitative and reliable identification of amphiphilic LPS in complex samples like beef homogenates. In addition, we also demonstrated that LPS-induced hole formation does not occur under the conditions of the membrane insertion assays. Together, these findings describe for the first time the serogroup-specific detection of amphiphilic LPS in complex samples using a membrane insertion assay, and highlight the importance of LPS molecular conformations in detection architectures.« less
Improved composite material and method for production of improved composite material
NASA Technical Reports Server (NTRS)
Farley, Gary L. (Inventor)
1994-01-01
A laminated composite material with improved interlaminar strength and damage tolerance having short rods distributed evenly throughout the composite material perpendicular to the laminae is introduced. Each rod is shorter than the thickness of the finished laminate, but several times as long as the thickness of each lamina. The laminate is made by inserting short rods in layers of prepreg material, and then stacking and curing prepreg material with rods inserted therethrough.
2017-03-03
biomechanical gait state changes within prolonged exercise or training events. II. MATERIAL AND METHODS A. Instrumented Insert Design We developed a...beginning and end of each data collection trial using a user interface designed specifically for this purpose in MATLAB. F. Calibration Proces:Static...consisted of walking for several minutes indoors (thin carpeted surface on concrete) and outdoors on several different surfaces ( pavement , gravel and
Inserting Agility in System Development
2012-07-01
Agile IT Acquisition, IT Box, Scrum Inserting Agility in System Development Matthew R. Kennedy and Lt Col Dan Ward, USAF With the fast-paced nature...1,700 individuals and 71 countries, found Scrum and eXtreme Programming to be the most widely followed method- ologies (VersionOne, 2007). Other...University http://www.dau.mil 259 Defense ARJ, July 2012, Vol. 19 No. 3 : 249–264 Scrum Scrum is a framework used for project management, which is
Adam, Ahmed
2017-01-01
Objective To describe a simple, novel method to achieve ureteric access in the Cohen crossed reimplanted ureter, which will allow retrograde working access via the conventional transurethral method. Materials and Methods Under cystoscopic vision, suprapubic needle puncture was performed. The needle was directed (bevel facing) towards the desired ureteric orifice (UO). A guidewire (with a floppy-tip) was then inserted into the suprapubic needle passing into the bladder, and then easily passed into the crossed-reimplanted UO. The distal end of the guidewire was then removed through the urethra with cystoscopic grasping forceps. The straightened ureter then easily facilitated ureteroscopy access, retrograde pyelogram studies, and JJ stent insertion in a conventional transurethral method. Results The UO and ureter were aligned in a more conventional orthotopic course, to allow for conventional transurethral working access. Conclusion A novel method to access the Cohen crossed reimplanted ureter was described. All previously published methods of accessing the crossed ureter were critically appraised. PMID:29463976
Mitochondrial DNA transfer to the nucleus generates extensive insertion site variation in maize.
Lough, Ashley N; Roark, Leah M; Kato, Akio; Ream, Thomas S; Lamb, Jonathan C; Birchler, James A; Newton, Kathleen J
2008-01-01
Mitochondrial DNA (mtDNA) insertions into nuclear chromosomes have been documented in a number of eukaryotes. We used fluorescence in situ hybridization (FISH) to examine the variation of mtDNA insertions in maize. Twenty overlapping cosmids, representing the 570-kb maize mitochondrial genome, were individually labeled and hybridized to root tip metaphase chromosomes from the B73 inbred line. A minimum of 15 mtDNA insertion sites on nine chromosomes were detectable using this method. One site near the centromere on chromosome arm 9L was identified by a majority of the cosmids. To examine variation in nuclear mitochondrial DNA sequences (NUMTs), a mixture of labeled cosmids was applied to chromosome spreads of ten diverse inbred lines: A188, A632, B37, B73, BMS, KYS, Mo17, Oh43, W22, and W23. The number of detectable NUMTs varied dramatically among the lines. None of the tested inbred lines other than B73 showed the strong hybridization signal on 9L, suggesting that there is a recent mtDNA insertion at this site in B73. Different sources of B73 and W23 were examined for NUMT variation within inbred lines. Differences were detectable, suggesting either that mtDNA is being incorporated or lost from the maize nuclear genome continuously. The results indicate that mtDNA insertions represent a major source of nuclear chromosomal variation.
Recent developments in turning hardened steels - A review
NASA Astrophysics Data System (ADS)
Sivaraman, V.; Prakash, S.
2017-05-01
Hard materials ranging from HRC 45 - 68 such as hardened AISI H13, AISI 4340, AISI 52100, D2 STL, D3 STEEL Steel etc., need super hard tool materials to machine. Turning of these hard materials is termed as hard turning. Hard turning makes possible direct machining of the hard materials and also eliminates the lubricant requirement and thus favoring dry machining. Hard turning is a finish turning process and hence conventional grinding is not required. Development of the new advanced super hard tool materials such as ceramic inserts, Cubic Boron Nitride, Polycrystalline Cubic Boron Nitride etc. enabled the turning of these materials. PVD and CVD methods of coating have made easier the production of single and multi layered coated tool inserts. Coatings of TiN, TiAlN, TiC, Al2O3, AlCrN over cemented carbide inserts has lead to the machining of difficult to machine materials. Advancement in the process of hard machining paved way for better surface finish, long tool life, reduced tool wear, cutting force and cutting temperatures. Micro and Nano coated carbide inserts, nanocomposite coated PCBN inserts, micro and nano CBN coated carbide inserts and similar developments have made machining of hardened steels much easier and economical. In this paper, broad literature review on turning of hardened steels including optimizing process parameters, cooling requirements, different tool materials etc., are done.
Kim, Junho; Maeng, Ju Heon; Lim, Jae Seok; Son, Hyeonju; Lee, Junehawk; Lee, Jeong Ho; Kim, Sangwoo
2016-10-15
Advances in sequencing technologies have remarkably lowered the detection limit of somatic variants to a low frequency. However, calling mutations at this range is still confounded by many factors including environmental contamination. Vector contamination is a continuously occurring issue and is especially problematic since vector inserts are hardly distinguishable from the sample sequences. Such inserts, which may harbor polymorphisms and engineered functional mutations, can result in calling false variants at corresponding sites. Numerous vector-screening methods have been developed, but none could handle contamination from inserts because they are focusing on vector backbone sequences alone. We developed a novel method-Vecuum-that identifies vector-originated reads and resultant false variants. Since vector inserts are generally constructed from intron-less cDNAs, Vecuum identifies vector-originated reads by inspecting the clipping patterns at exon junctions. False variant calls are further detected based on the biased distribution of mutant alleles to vector-originated reads. Tests on simulated and spike-in experimental data validated that Vecuum could detect 93% of vector contaminants and could remove up to 87% of variant-like false calls with 100% precision. Application to public sequence datasets demonstrated the utility of Vecuum in detecting false variants resulting from various types of external contamination. Java-based implementation of the method is available at http://vecuum.sourceforge.net/ CONTACT: swkim@yuhs.acSupplementary information: Supplementary data are available at Bioinformatics online. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
Thomson, Callum M; Esparon, Tom; Rea, Paul M; Jamal, Bilal
2016-10-01
The use of external fixation for intra-articular calcaneal fractures is increasing in popularity. Studies have shown fine wire and monoaxial external fixation to be a viable surgical alternative to more invasive methods of open reduction and internal fixation of the calcaneus. However, there is an absence of literature that quantifies the risk of pin insertion for monoaxial fixation. This study aimed to determine the safety of inserting monoaxial pins within the calcaneus to house the Orthofix Calcaneal Mini-Fixator. Five formalin embalmed cadaveric ankle and lower leg specimens were inserted with six monoaxial pins. Careful dissection then revealed the presence of the tendons of peroneus longus and brevis, the sural nerve and the small saphenous vein in relation to these pins. Measurements from each pin to each of these structures were made as the structures transected lines drawn from each pin to two palpable bony landmarks: the inferior tip of the lateral malleolus and the posterosuperior calcaneus. In doing this, the risk posed by each pin could be evaluated. We found that two particular pins, those used to hold the articular surface of the subtalar joint in a reduced position, posed a larger risk of injury to surrounding structures than the remaining pins. These findings therefore suggest that monoaxial fixation of the calcaneus using a six pin approach is a relatively safe method of rectifying calcaneal fractures and thus may serve as a welcome alternative to other methods of calcaneal fixation. Copyright © 2016 Elsevier Ltd. All rights reserved.
Acceptability of the vaginal contraceptive ring among adolescent women.
Terrell, Lekeisha R; Tanner, Amanda E; Hensel, Devon J; Blythe, Margaret J; Fortenberry, J Dennis
2011-08-01
Although underutilized, the vaginal contraceptive ring has several advantages over other contraceptive methods that could benefit adolescents. We examined factors that may influence willingness to try the vaginal ring including: sexual and contraceptive history, genital comfort, and vaginal ring characteristics. Cross sectional Midwestern adolescent health clinics Adolescent women (N = 200; 14-18 years; 89% African-American) INTERVENTIONS/MAIN OUTCOME MEASURES: All participants received education about the vaginal ring and viewed pictures demonstrating insertion; they then completed a visual/audio computer-assisted self interview. The primary outcome variable, willingness to try the vaginal ring, was a single Likert-scale item. Over half the participants reported knowledge of the vaginal ring with healthcare providers identified as the most important source of contraceptive information. Comfort with one's genitals, insertion and removal, using alternative methods of insertion, and knowing positive method characteristics were significantly associated with willingness to try the vaginal ring. A decreased willingness to try the vaginal ring was related to concerns of the ring getting lost inside or falling out of the vagina. Willingness to try the ring was associated with positive feelings about genitals (e.g., comfort with appearance, hygiene, function). Thus, to increase willingness to try the vaginal ring among adolescents, providers should make it common practice to discuss basic female reproductive anatomy, raise awareness about female genital health and address concerns about their genitals. Providers can offer alternative insertion techniques (e.g., gloves) to make use more accessible. These strategies may increase vaginal ring use among adolescents. 2011 North American Society for Pediatric and Adolescent Gynecology. Published by Elsevier Inc. All rights reserved.
Use of Medicare summary notice inserts to generate interest in the Medicare stop smoking program.
Maglione, Margaret; Larson, Carrie; Giannotti, Tierney; Lapin, Pauline
2007-01-01
Evaluations of outreach strategies that effectively and efficiently reach the senior population often go unreported. The Medicare Stop Smoking Program (MSSP) was a seven-state demonstration project funded by the Centers for Medicare and Medicaid Services. The 1-year recruitment plan for MSSP included a multifaceted paid media campaign; however, enrollment was slower than anticipated. The purpose of this substudy was to test the effects of including envelope-sized advertisement inserts with Medicare Summary Notices (MSNs) as a supplemental recruitment strategy. Information obtained from enrollees on where they had learned about the program as well as overall enrollment rates were analyzed and compared with the time periods during which the inserts were included in MSN mailings. Average call volume to the enrollment center increased by 65.7% in Alabama, the pilot state, and by more than 200% in the subsequent demonstration states. Despite the introduction of the MSN inserts late in the recruitment period, 32.2 % of the 7354 total enrollees stated that they learned about the project through the inserts. This recruitment method is highly recommended as a cost-effective way to reach the senior population.
Comparison of nine methods to estimate ear-canal stimulus levels
Souza, Natalie N.; Dhar, Sumitrajit; Neely, Stephen T.; Siegel, Jonathan H.
2014-01-01
The reliability of nine measures of the stimulus level in the human ear canal was compared by measuring the sensitivity of behavioral hearing thresholds to changes in the depth of insertion of an otoacoustic emission probe. Four measures were the ear-canal pressure, the eardrum pressure estimated from it and the pressure measured in an ear simulator with and without compensation for insertion depth. The remaining five quantities were derived from the ear-canal pressure and the Thévenin-equivalent source characteristics of the probe: Forward pressure, initial forward pressure, the pressure transmitted into the middle ear, eardrum sound pressure estimated by summing the magnitudes of the forward and reverse pressure (integrated pressure) and absorbed power. Two sets of behavioral thresholds were measured in 26 subjects from 0.125 to 20 kHz, with the probe inserted at relatively deep and shallow positions in the ear canal. The greatest dependence on insertion depth was for transmitted pressure and absorbed power. The measures with the least dependence on insertion depth throughout the frequency range (best performance) included the depth-compensated simulator, eardrum, forward, and integrated pressures. Among these, forward pressure is advantageous because it quantifies stimulus phase. PMID:25324079
Yamaguchi, Satoshi; Tsutsui, Kihei; Satake, Koji; Morikawa, Shigehiro; Shirai, Yoshiaki; Tanaka, Hiromi T
2014-10-01
Our goal was to develop a three-dimensional finite element model that enables dynamic analysis of needle insertion for soft materials. To demonstrate large deformation and fracture, we used the arbitrary Lagrangian-Eulerian (ALE) method for fluid analysis. We performed ALE-based finite element analysis for 3% agar gel and three types of copper needle with bevel tips. To evaluate simulation results, we compared the needle deflection and insertion force with corresponding experimental results acquired with a uniaxial manipulator. We studied the shear stress distribution of agar gel on various time scales. For 30°, 45°, and 60°, differences in deflections of each needle between both sets of results were 2.424, 2.981, and 3.737mm, respectively. For the insertion force, there was no significant difference for mismatching area error (p<0.05) between simulation and experimental results. Our results have the potential to be a stepping stone to develop pre-operative surgical planning to estimate an optimal needle insertion path for MR image-guided microwave coagulation therapy and for analyzing large deformation and fracture in biological tissues. Copyright © 2014 Elsevier Ltd. All rights reserved.
Ryu, Junghee; Oh, Ah Young; Baek, Ji-Seok; Kim, Jin-Hee; Park, Sang-Heon; Noh, Jae-Mun
2014-04-01
This study determined the dose of remifentanil to use during insertion of a Classic™ laryngeal mask airway (LMA, The Laryngeal Mask Co., Nicosia, Cyprus) in elderly patients during emergency airway management when combined with a single dose of propofol. Patients aged 65-80 years were enrolled. Anesthesia was induced with propofol 1 mg/kg, and then a blinded dose of remifentanil was infused over 30 s after confirming the patient's loss of consciousness. The dose of remifentanil was determined using Dixon's up-and-down method, starting at 0.5 µg/kg (a step size of 0.1 µg/kg). Insertion of the LMA was attempted 60 s after loss of consciousness. In total, 23 patients were recruited and the mean age ± standard deviation was 72 ± 3 years. The effective dose for successful LMA insertion in 50% of the patients (ED50) was 0.20 ± 0.05 µg/kg. No patient needed more than 0.3 µg/kg. Remifentanil 0.20 ± 0.05 µg/kg with propofol 1 mg/kg resulted in excellent LMA insertion in 50% of elderly patients without significant hemodynamic changes during emergency airway management.
NASA Astrophysics Data System (ADS)
Dmitriyeva, Olga; Hamm, Steven C.; Knies, David L.; Cantwell, Richard; McConnell, Matt
2018-05-01
Our previous work experimentally demonstrated the enhancement of electrochemical hydrogen insertion into palladium by modifying the chemical composition of the cathode surface with Pb, Pt and Bi, referred to as surface promoters. The experiment demonstrated that an optimal combination of the surface promoters led to an increase in hydrogen fugacity of more than three orders of magnitude, while maintaining the same current density. This manuscript discusses the application of Density Functional Theory (DFT) to elucidate the thermodynamics and kinetics of observed enhancement of electrochemical hydrogen insertion into palladium. We present theoretical simulations that: (1) establish the elevation of hydrogen's chemical potential on Pb and Bi surfaces to enhance hydrogen insertion, (2) confirm the increase of a Tafel activation barrier that results in a decrease of the reaction rate at the given hydrogen overpotential, and (3) explain why the surface promoter's coverage needs to be non-uniform, namely to allow hydrogen insertion into palladium bulk while simultaneously locking hydrogen below the surface (the corking effect). The discussed DFT-based method can be used for efficient scanning of different material configurations to design a highly effective hydrogen storage system.
Clark, Edward G; Paparello, James J; Wayne, Diane B; Edwards, Cedric; Hoar, Stephanie; McQuillan, Rory; Schachter, Michael E; Barsuk, Jeffrey H
2014-01-01
Simulation-based-mastery-learning (SBML) is an effective method to train nephrology fellows to competently insert temporary, non-tunneled hemodialysis catheters (NTHCs). Previous studies of SBML for NTHC-insertion have been conducted at a local level. Determine if SBML for NTHC-insertion can be effective when provided at a national continuing medical education (CME) meeting. Describe the correlation of demographic factors, prior experience with NTHC-insertion and procedural self-confidence with simulated performance of the procedure. Pre-test - post-test study. 2014 Canadian Society of Nephrology annual meeting. Nephrology fellows, internal medicine residents and medical students. Participants were surveyed regarding demographics, prior NTHC-insertion experience, procedural self-confidence and attitudes regarding the training they received. NTHC-insertion skills were assessed using a 28-item checklist. Participants underwent a pre-test of their NTHC-insertion skills at the internal jugular site using a realistic patient simulator and ultrasound machine. Participants then had a training session that included a didactic presentation and 2 hours of deliberate practice using the simulator. On the following day, trainees completed a post-test of their NTHC-insertion skills. All participants were required to meet or exceed a minimum passing score (MPS) previously set at 79%. Trainees who did not reach the MPS were required to perform more deliberate practice until the MPS was achieved. Twenty-two individuals participated in SBML training. None met or exceeded the MPS at baseline with a median checklist score of 20 (IQR, 7.25 to 21). Seventeen of 22 participants (77%) completed post-testing and improved their scores to a median of 27 (IQR, 26 to 28; p < 0.001). All met or exceeded the MPS on their first attempt. There were no significant correlations between demographics, prior experience or procedural self-confidence with pre-test performance. Small sample-size and self-selection of participants. Costs could limit the long-term feasibility of providing this type of training at a CME conference. Despite most participants reporting having previously inserted NTHCs in clinical practice, none met the MPS at baseline; this suggests their prior training may have been inadequate.
Bhattacharyya, Rahul; Ker, Andrew; Fogg, Quentin; Spencer, Simon J; Joseph, Jibu
2018-02-01
Incorrect femoral tunnel placement is the most common cause of graft failure during Anterior Cruciate Ligament (ACL) Reconstruction. A reliable landmark can minimize errors. To identify whether the Lateral Intercondylar Ridge (LIR) is a consistent anatomical structure and define its relationship with the femoral ACL insertion. Phase 1: we studied 23 femoral dry bone specimens macroscopically. Using a digital microscribe, the medial surface of the lateral femoral condyle was reconstructed (3D) to evaluate whether there was an identifiable bony ridge. Phase 2: 7 cadaveric specimens with intact soft tissues were dissected to identify the femoral ACL insertion. A 3D reconstruction of the femoral ACL insertion and the surface allowed us to define the relationship between the LIR and the ACL insertion. All specimens had a defined LIR on the medial surface of the lateral femoral condyle. The ridge was consistently located just anterior to the femoral ACL insertion. The ACL footprint was present in the depression between the ridge and the Inferior Articular Cartilage Margin (IACM). The mean distance from the midpoint of the IACM to the LIR was 10.1 mm. This is the first study to use the microscribe to digitally reconstruct the medial surface of the lateral femoral condyle. It shows that the LIR is a consistent anatomical structure that defines the anterior margin of the femoral ACL insertion, which guides femoral tunnel placement. Our findings support the ruler technique, which is a commonly used method for anatomic single bundle ACL reconstruction. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Bolzoni, Paolo; Somogyi, Gábor; Trócsányi, Zoltán
2011-01-01
We perform the integration of all iterated singly-unresolved subtraction terms, as defined in ref. [1], over the two-particle factorized phase space. We also sum over the unresolved parton flavours. The final result can be written as a convolution (in colour space) of the Born cross section and an insertion operator. We spell out the insertion operator in terms of 24 basic integrals that are defined explicitly. We compute the coefficients of the Laurent expansion of these integrals in two different ways, with the method of Mellin-Barnes representations and sector decomposition. Finally, we present the Laurent-expansion of the full insertion operator for the specific examples of electron-positron annihilation into two and three jets.
Haubruck, Patrick; Nickel, Felix; Ober, Julian; Walker, Tilman; Bergdolt, Christian; Friedrich, Mirco; Müller-Stich, Beat Peter; Forchheim, Franziska; Fischer, Christian; Schmidmaier, Gerhard; Tanner, Michael C
2018-05-21
The insertion of a chest tube should be as quick and accurate as possible to maximize the benefit and minimize possible complications for the patient. Therefore, comprehensive training and assessment before an emergency situation are essential for proficiency in chest tube insertion. Serious games have become more prevalent in surgical training because they enable students to study and train a procedure independently, and errors made have no effect on patients. However, up-to-date evidence regarding the effect of serious games on performance in procedures in emergency medicine remains scarce. The aim of this study was to investigate the serious gaming approach in teaching medical students an emergency procedure (chest tube insertion) using the app Touch Surgery and a modified objective structural assessment of technical skills (OSATS). In a prospective, rater-blinded, randomized controlled trial, medical students were randomized into two groups: intervention group or control group. Touch Surgery has been established as an innovative and cost-free app for mobile devices. The fully automatic software enables users to train medical procedures and afterwards self-assess their training effort. The module chest tube insertion teaches each key step in the insertion of a chest tube and enables users the meticulous application of a chest tube. In contrast, the module "Thoracocentesis" discusses a basic thoracocentesis. All students attended a lecture regarding chest tube insertion (regular curriculum) and afterwards received a Touch Surgery training lesson: intervention group used the module chest tube insertion and the control group used Thoracocentesis as control training. Participants' performance in chest tube insertion on a porcine model was rated on-site via blinded face-to-face rating and via video recordings using a modified OSATS tool. Afterwards, every participant received an individual questionnaire for self-evaluation. Here, trainees gave information about their individual training level, as well as previous experiences, gender, and hobbies. Primary end point was operative performance during chest tube insertion by direct observance. A total of 183 students enrolled, 116 students participated (63.4%), and 21 were excluded because of previous experiences in chest tube insertion. Students were randomized to the intervention group (49/95, 52%) and control group (46/95, 48%). The intervention group performed significantly better than the control group (Intervention group: 38.0 [I 50 =7.0] points; control group: 30.5 [I 50 =8.0] points; P<.001). The intervention group showed significantly improved economy of time and motion (P=.004), needed significantly less help (P<.001), and was more confident in handling of instruments (P<.001) than the control group. The results from this study show that serious games are a valid and effective tool in education of operative performance in chest tube insertion. We believe that serious games should be implemented in the surgical curriculum, as well as residency programs, in addition to traditional learning methods. German Clinical Trials Register (DRKS) DRKS00009994; https://www.drks.de/drks_web/navigate.do?navigationId=trial.HTML&TRIAL_ID=DRKS00009994 (Archived by Webcite at http://www.webcitation.org/6ytWF1CWg). ©Patrick Haubruck, Felix Nickel, Julian Ober, Tilman Walker, Christian Bergdolt, Mirco Friedrich, Beat Peter Müller-Stich, Franziska Forchheim, Christian Fischer, Gerhard Schmidmaier, Michael C Tanner. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 21.05.2018.
Internal carotid artery rupture caused by carotid shunt insertion
Illuminati, Giulio; Caliò, Francesco G.; Pizzardi, Giulia; Vietri, Francesco
2015-01-01
Introduction Shunting is a well-accepted method of maintaining cerebral perfusion during carotid endarterectomy (CEA). Nonetheless, shunt insertion may lead to complications including arterial dissection, embolization, and thrombosis. We present a complication of shunt insertion consisting of arterial wall rupture, not reported previously. Presentation of case A 78-year-old woman underwent CEA combined with coronary artery bypass grafting (CABG). At the time of shunt insertion an arterial rupture at the distal tip of the shunt was detected and was repaired via a small saphenous vein patch. Eversion CEA and subsequent CABG completed the procedure whose postoperative course was uneventful. Discussion Shunting during combined CEA-CABG may be advisable to assure cerebral protection from possible hypoperfusion due to potential hemodynamic instability of patients with severe coronary artery disease. Awareness and prompt management of possible shunt-related complications, including the newly reported one, may contribute to limiting their harmful effect. Conclusion Arterial wall rupture is a possible, previously not reported, shunt-related complication to be aware of when performing CEA. PMID:26255001
Seal welded cast iron nuclear waste container
Filippi, Arthur M.; Sprecace, Richard P.
1987-01-01
This invention identifies methods and articles designed to circumvent metallurgical problems associated with hermetically closing an all cast iron nuclear waste package by welding. It involves welding nickel-carbon alloy inserts which are bonded to the mating plug and main body components of the package. The welding inserts might be bonded in place during casting of the package components. When the waste package closure weld is made, the most severe thermal effects of the process are restricted to the nickel-carbon insert material which is far better able to accommodate them than is cast iron. Use of nickel-carbon weld inserts should eliminate any need for pre-weld and post-weld heat treatments which are a problem to apply to nuclear waste packages. Although the waste package closure weld approach described results in a dissimilar metal combination, the relative surface area of nickel-to-iron, their electrochemical relationship, and the presence of graphite in both materials will act to prevent any galvanic corrosion problem.
NASA Astrophysics Data System (ADS)
Vasu, M.; Shivananda, Nayaka H.
2018-04-01
EN47 steel samples are machined on a self-centered lathe using Chemical Vapor Deposition of coated TiCN/Al2O3/TiN and uncoated tungsten carbide tool inserts, with nose radius 0.8mm. Results are compared with each other and optimized using statistical tool. Input (cutting) parameters that are considered in this work are feed rate (f), cutting speed (Vc), and depth of cut (ap), the optimization criteria are based on the Taguchi (L9) orthogonal array. ANOVA method is adopted to evaluate the statistical significance and also percentage contribution for each model. Multiple response characteristics namely cutting force (Fz), tool tip temperature (T) and surface roughness (Ra) are evaluated. The results discovered that coated tool insert (TiCN/Al2O3/TiN) exhibits 1.27 and 1.29 times better than the uncoated tool insert for tool tip temperature and surface roughness respectively. A slight increase in cutting force was observed for coated tools.
Topology Trivialization and Large Deviations for the Minimum in the Simplest Random Optimization
NASA Astrophysics Data System (ADS)
Fyodorov, Yan V.; Le Doussal, Pierre
2014-01-01
Finding the global minimum of a cost function given by the sum of a quadratic and a linear form in N real variables over (N-1)-dimensional sphere is one of the simplest, yet paradigmatic problems in Optimization Theory known as the "trust region subproblem" or "constraint least square problem". When both terms in the cost function are random this amounts to studying the ground state energy of the simplest spherical spin glass in a random magnetic field. We first identify and study two distinct large-N scaling regimes in which the linear term (magnetic field) leads to a gradual topology trivialization, i.e. reduction in the total number {N}_{tot} of critical (stationary) points in the cost function landscape. In the first regime {N}_{tot} remains of the order N and the cost function (energy) has generically two almost degenerate minima with the Tracy-Widom (TW) statistics. In the second regime the number of critical points is of the order of unity with a finite probability for a single minimum. In that case the mean total number of extrema (minima and maxima) of the cost function is given by the Laplace transform of the TW density, and the distribution of the global minimum energy is expected to take a universal scaling form generalizing the TW law. Though the full form of that distribution is not yet known to us, one of its far tails can be inferred from the large deviation theory for the global minimum. In the rest of the paper we show how to use the replica method to obtain the probability density of the minimum energy in the large-deviation approximation by finding both the rate function and the leading pre-exponential factor.
Generic dynamical phase transition in one-dimensional bulk-driven lattice gases with exclusion
NASA Astrophysics Data System (ADS)
Lazarescu, Alexandre
2017-06-01
Dynamical phase transitions are crucial features of the fluctuations of statistical systems, corresponding to boundaries between qualitatively different mechanisms of maintaining unlikely values of dynamical observables over long periods of time. They manifest themselves in the form of non-analyticities in the large deviation function of those observables. In this paper, we look at bulk-driven exclusion processes with open boundaries. It is known that the standard asymmetric simple exclusion process exhibits a dynamical phase transition in the large deviations of the current of particles flowing through it. That phase transition has been described thanks to specific calculation methods relying on the model being exactly solvable, but more general methods have also been used to describe the extreme large deviations of that current, far from the phase transition. We extend those methods to a large class of models based on the ASEP, where we add arbitrary spatial inhomogeneities in the rates and short-range potentials between the particles. We show that, as for the regular ASEP, the large deviation function of the current scales differently with the size of the system if one considers very high or very low currents, pointing to the existence of a dynamical phase transition between those two regimes: high current large deviations are extensive in the system size, and the typical states associated to them are Coulomb gases, which are highly correlated; low current large deviations do not depend on the system size, and the typical states associated to them are anti-shocks, consistently with a hydrodynamic behaviour. Finally, we illustrate our results numerically on a simple example, and we interpret the transition in terms of the current pushing beyond its maximal hydrodynamic value, as well as relate it to the appearance of Tracy-Widom distributions in the relaxation statistics of such models. , which features invited work from the best early-career researchers working within the scope of J. Phys. A. This project is part of the Journal of Physics series’ 50th anniversary celebrations in 2017. Alexandre Lazarescu was selected by the Editorial Board of J. Phys. A as an Emerging Talent.
Electrical connector composite housing and method of making same
Silva, Frank A.
1979-01-01
A sleeve-like insert of conductive elastomeric material of a type which serves as an internal shield in electrical connectors for connecting high voltage cables has an end portion folded upon itself, the enfolded portion being substantially permanently retained in its desired position by allowing insulative elastomeric material to fill apertures in the end portion and become bonded thereto in a void free manner, during molding of an insulating outer sleeve-like jacket about the insert.
FABRICATION OF NEUTRON SOURCES
Birden, J.H.
1959-01-20
A method is presented for preparing a more efficient neutron source comprising inserting in a container a quantity of Po-210, inserting B powder coated with either Ag, Pt, or Ni. The container is sealed and then slowly heated to about 450 C to volatilize the Po and effect combination of the coated powder with the Po. The neutron flux emitted by the unit is moritored and the heating step is terminated when the flux reaches a maximum or selected level.
Frimodt-Møller, Jakob; Charbon, Godefroid; Krogfelt, Karen A; Løbner-Olesen, Anders
2017-09-11
The optimal chromosomal position(s) of a given DNA element was/were determined by transposon-mediated random insertion followed by fitness selection. In bacteria, the impact of the genetic context on the function of a genetic element can be difficult to assess. Several mechanisms, including topological effects, transcriptional interference from neighboring genes, and/or replication-associated gene dosage, may affect the function of a given genetic element. Here, we describe a method that permits the random integration of a DNA element into the chromosome of Escherichia coli and select the most favorable locations using a simple growth competition experiment. The method takes advantage of a well-described transposon-based system of random insertion, coupled with a selection of the fittest clone(s) by growth advantage, a procedure that is easily adjustable to experimental needs. The nature of the fittest clone(s) can be determined by whole-genome sequencing on a complex multi-clonal population or by easy gene walking for the rapid identification of selected clones. Here, the non-coding DNA region DARS2, which controls the initiation of chromosome replication in E. coli, was used as an example. The function of DARS2 is known to be affected by replication-associated gene dosage; the closer DARS2 gets to the origin of DNA replication, the more active it becomes. DARS2 was randomly inserted into the chromosome of a DARS2-deleted strain. The resultant clones containing individual insertions were pooled and competed against one another for hundreds of generations. Finally, the fittest clones were characterized and found to contain DARS2 inserted in close proximity to the original DARS2 location.
Virtual Reality simulator for dental anesthesia training in the inferior alveolar nerve block.
Corrêa, Cléber Gimenez; Machado, Maria Aparecida de Andrade Moreira; Ranzini, Edith; Tori, Romero; Nunes, Fátima de Lourdes Santos
2017-01-01
This study shows the development and validation of a dental anesthesia-training simulator, specifically for the inferior alveolar nerve block (IANB). The system developed provides the tactile sensation of inserting a real needle in a human patient, using Virtual Reality (VR) techniques and a haptic device that can provide a perceived force feedback in the needle insertion task during the anesthesia procedure. To simulate a realistic anesthesia procedure, a Carpule syringe was coupled to a haptic device. The Volere method was used to elicit requirements from users in the Dentistry area; Repeated Measures Two-Way ANOVA (Analysis of Variance), Tukey post-hoc test and averages for the results' analysis. A questionnaire-based subjective evaluation method was applied to collect information about the simulator, and 26 people participated in the experiments (12 beginners, 12 at intermediate level, and 2 experts). The questionnaire included profile, preferences (number of viewpoints, texture of the objects, and haptic device handler), as well as visual (appearance, scale, and position of objects) and haptic aspects (motion space, tactile sensation, and motion reproduction). The visual aspect was considered appropriate and the haptic feedback must be improved, which the users can do by calibrating the virtual tissues' resistance. The evaluation of visual aspects was influenced by the participants' experience, according to ANOVA test (F=15.6, p=0.0002, with p<0.01). The user preferences were the simulator with two viewpoints, objects with texture based on images and the device with a syringe coupled to it. The simulation was considered thoroughly satisfactory for the anesthesia training, considering the needle insertion task, which includes the correct insertion point and depth, as well as the perception of tissues resistances during the insertion.
Model-based assist feature insertion for sub-40nm memory device
NASA Astrophysics Data System (ADS)
Suh, Sungsoo; Lee, Suk-joo; Choi, Seong-woon; Lee, Sung-Woo; Park, Chan-hoon
2009-04-01
Many issues need to be resolved for a production-worthy model based assist feature insertion flow for single and double exposure patterning process to extend low k1 process at 193 nm immersion technology. Model based assist feature insertion is not trivial to implement either for single and double exposure patterning compared to rule based methods. As shown in Fig. 1, pixel based mask inversion technology in itself has difficulties in mask writing and inspection although it presents as one of key technology to extend single exposure for contact layer. Thus far, inversion technology is tried as a cooptimization of target mask to simultaneously generate optimized main and sub-resolution assists features for a desired process window. Alternatively, its technology can also be used to optimize for a target feature after an assist feature types are inserted in order to simplify the mask complexity. Simplification of inversion mask is one of major issue with applying inversion technology to device development even if a smaller mask feature can be fabricated since the mask writing time is also a major factor. As shown in Figure 2, mask writing time may be a limiting factor in determining whether or not an inversion solution is viable. It can be reasoned that increased number of shot counts relates to increase in margin for inversion methodology. On the other hand, there is a limit on how complex a mask can be in order to be production worthy. There is also source and mask co-optimization which influences the final mask patterns and assist feature sizes and positions for a given target. In this study, we will discuss assist feature insertion methods for sub 40-nm technology.
Numerical investigations of MRI RF field induced heating for external fixation devices
2013-01-01
Background The magnetic resonance imaging (MRI) radio frequency (RF) field induced heating on external fixation devices can be very high in the vicinity of device screws. Such induced RF heating is related to device constructs, device placements, as well as the device insertion depth into human subjects. In this study, computational modeling is performed to determine factors associated with such induced heating. Methods Numerical modeling, based on the finite-difference time-domain (FDTD) method, is used to evaluate the temperature rises near external device screw tips inside the ASTM phantom for both 1.5-T and 3-T MRI systems. The modeling approach consists of 1) the development of RF coils for 1.5-T and 3-T, 2) the electromagnetic simulations of energy deposition near the screw tips of external fixation devices, and 3) the thermal simulations of temperature rises near the tips of these devices. Results It is found that changing insertion depth and screw spacing could largely affect the heating of these devices. In 1.5-T MRI system, smaller insertion depth and larger pin spacing will lead to higher temperature rise. However, for 3-T MRI system, the relation is not very clear when insertion depth is larger than 5 cm or when pin spacing became larger than 20 cm. The effect of connection bar material on device heating is also studied and the heating mechanism of the device is analysed. Conclusions Numerical simulation is used to study RF heating for external fixation devices in both 1.5-T and 3-T MRI coils. Typically, shallower insertion depth and larger pin spacing with conductive bar lead to higher RF heating. The heating mechanism is explained using induced current along the device and power decay inside ASTM phantom. PMID:23394173
A novel method for percutaneous insertion of a right ventricular assist device.
Avgerinos, Dimitrios V; DeBois, William; Mongero, Linda; Krieger, Karl; Salemi, Arash
2013-06-01
Right heart failure is a rare but often fatal complication both in the pre- and postoperative setting. Right heart support with a ventricular assist device inserted in the operating room through median sternotomy can be a time-consuming procedure that requires a reoperation for removal. In cases of urgent need of right heart support, a percutaneous technique option may be of benefit. We present our initial experience with a percutaneously inserted right ventricular assist device (RVAD) in an elderly patient with severe right heart failure. An 81-year-old female patient underwent combined aortic and mitral valve replacement at our institution. During the first postoperative evening, the patient sustained sudden cardiovascular collapse and a bedside transesophageal echocardiogram revealed severe right heart failure. A coronary angiogram showed thrombosis of the right coronary artery, which was cleared with a suction device. As a result of the patient's critical condition, it was decided that an RVAD was needed as a bridge to recovery. The patient's condition improved significantly almost immediately. Her right heart function recovered over the next few days and the RVAD was removed at the bedside. She made a complete recovery and was discharged home. This patient is a prime example that a totally RVAD can be inserted in urgent situations easily and safely under fluoroscopic and echocardiographic guidance. More clinical experience with percutaneous RVADs is required to establish this technique as an alternative equivalent to the traditional open method. Right heart failure complicates many heart diseases both in the pre- and the postoperative setting. In cases of urgent need of right heart support, a percutaneous technique of a RVAD is needed for a successful outcome. We present our initial experience with a percutaneously inserted RVAD in an elderly patient with severe postoperative right heart failure.
Foot pressures during gait: a comparison of techniques for reducing pressure points.
Lawless, M W; Reveal, G T; Laughlin, R T
2001-07-01
Various methods have been used to redistribute plantar surface foot pressure in patients with foot ulcers. This study was conducted to determine the effectiveness of four modalities (fracture walker, fracture walker with insert, and open and closed toe total contact casts) in reducing plantar foot pressure. Ten healthy, normal volunteer subjects had an F-scan sensor (ultra thin shoe insert pressure monitor) placed under the right foot. They then ambulated on a flat surface, maintaining their normal gait. Dynamic plantar pressures were averaged over 10 steps at four different sites (plantar surface of great toe, first metatarsal head, base of fifth metatarsal, and plantar heel). All subjects repeated this sequence under five different testing conditions (barefoot, with a fracture walker, fracture walker with arch support insert, open and closed toe total contact cast). Each subject's barefoot pressures were then compared with the pressures during the different modalities. All four treatment modalities significantly reduced (p < 0.05) plantar pressure at the first metatarsal head (no method was superior). The fracture walker, fracture walker with insert, and open toe total contact cast significantly reduced pressure at the heel. Pressures at the base of the fifth metatarsal and great toe were not significantly reduced with any treatment form. The fracture walker, with and without arch support, and total contact cast can effectively reduce plantar pressure at the heel and first metatarsal head.
Santamaría-Arrieta, Gorka; Brizuela-Velasco, Aritza; Fernández-González, Felipe J.; Chávarri-Prado, David; Chento-Valiente, Yelko; Solaberrieta, Eneko; Diéguez-Pereira, Markel; Yurrebaso-Asúa, Jaime
2016-01-01
Background This study evaluated the influence of implant site preparation depth on primary stability measured by insertion torque and resonance frequency analysis (RFA). Material and Methods Thirty-two implant sites were prepared in eight veal rib blocks. Sixteen sites were prepared using the conventional drilling sequence recommended by the manufacturer to a working depth of 10mm. The remaining 16 sites were prepared using an oversize drilling technique (overpreparation) to a working depth of 12mm. Bone density was determined using cone beam computerized tomography (CBCT). The implants were placed and primary stability was measured by two methods: insertion torque (Ncm), and RFA (implant stability quotient [ISQ]). Results The highest torque values were achieved by the conventional drilling technique (10mm). The ANOVA test confirmed that there was a significant correlation between torque and drilling depth (p<0.05). However, no statistically significant differences were obtained between ISQ values at 10 or 12 mm drilling depths (p>0.05) at either measurement direction (cortical and medullar). No statistical relation between torque and ISQ values was identified, or between bone density and primary stability (p >0.05). Conclusions Vertical overpreparation of the implant bed will obtain lower insertion torque values, but does not produce statistically significant differences in ISQ values. Key words:Implant stability quotient, overdrilling, primary stability, resonance frequency analysis, torque. PMID:27398182
Deep Logic Networks: Inserting and Extracting Knowledge From Deep Belief Networks.
Tran, Son N; d'Avila Garcez, Artur S
2018-02-01
Developments in deep learning have seen the use of layerwise unsupervised learning combined with supervised learning for fine-tuning. With this layerwise approach, a deep network can be seen as a more modular system that lends itself well to learning representations. In this paper, we investigate whether such modularity can be useful to the insertion of background knowledge into deep networks, whether it can improve learning performance when it is available, and to the extraction of knowledge from trained deep networks, and whether it can offer a better understanding of the representations learned by such networks. To this end, we use a simple symbolic language-a set of logical rules that we call confidence rules-and show that it is suitable for the representation of quantitative reasoning in deep networks. We show by knowledge extraction that confidence rules can offer a low-cost representation for layerwise networks (or restricted Boltzmann machines). We also show that layerwise extraction can produce an improvement in the accuracy of deep belief networks. Furthermore, the proposed symbolic characterization of deep networks provides a novel method for the insertion of prior knowledge and training of deep networks. With the use of this method, a deep neural-symbolic system is proposed and evaluated, with the experimental results indicating that modularity through the use of confidence rules and knowledge insertion can be beneficial to network performance.
Imaging light responses of foveal ganglion cells in the living macaque eye.
Yin, Lu; Masella, Benjamin; Dalkara, Deniz; Zhang, Jie; Flannery, John G; Schaffer, David V; Williams, David R; Merigan, William H
2014-05-07
The fovea dominates primate vision, and its anatomy and perceptual abilities are well studied, but its physiology has been little explored because of limitations of current physiological methods. In this study, we adapted a novel in vivo imaging method, originally developed in mouse retina, to explore foveal physiology in the macaque, which permits the repeated imaging of the functional response of many retinal ganglion cells (RGCs) simultaneously. A genetically encoded calcium indicator, G-CaMP5, was inserted into foveal RGCs, followed by calcium imaging of the displacement of foveal RGCs from their receptive fields, and their intensity-response functions. The spatial offset of foveal RGCs from their cone inputs makes this method especially appropriate for fovea by permitting imaging of RGC responses without excessive light adaptation of cones. This new method will permit the tracking of visual development, progression of retinal disease, or therapeutic interventions, such as insertion of visual prostheses.
Theories of Variable Mass Particles and Low Energy Nuclear Phenomena
NASA Astrophysics Data System (ADS)
Davidson, Mark
2014-02-01
Variable particle masses have sometimes been invoked to explain observed anomalies in low energy nuclear reactions (LENR). Such behavior has never been observed directly, and is not considered possible in theoretical nuclear physics. Nevertheless, there are covariant off-mass-shell theories of relativistic particle dynamics, based on works by Fock, Stueckelberg, Feynman, Greenberger, Horwitz, and others. We review some of these and we also consider virtual particles that arise in conventional Feynman diagrams in relativistic field theories. Effective Lagrangian models incorporating variable mass particle theories might be useful in describing anomalous nuclear reactions by combining mass shifts together with resonant tunneling and other effects. A detailed model for resonant fusion in a deuterium molecule with off-shell deuterons and electrons is presented as an example. Experimental means of observing such off-shell behavior directly, if it exists, is proposed and described. Brief explanations for elemental transmutation and formation of micro-craters are also given, and an alternative mechanism for the mass shift in the Widom-Larsen theory is presented. If variable mass theories were to find experimental support from LENR, then they would undoubtedly have important implications for the foundations of quantum mechanics, and practical applications may arise.
Ryan, Joseph P; Testa, Mark F; Zhai, Fuhua
2008-01-01
Juvenile delinquency remains a significant problem for child welfare systems throughout the United States. Victims of child abuse and neglect are more likely relative to children in the general population to engage in delinquency (Ryan & Testa, 2005; Widom, 1989). Although the magnitude of this relationship is not fully understood (Zingraff, Leiter, Myers, & Johnsen, 1993), the risk of delinquency is particularly high for African American males, adolescents, and children in substitute care settings. Unfortunately little is known about the factors that connect the experiences of maltreatment and delinquency. This lack of knowledge makes it nearly impossible to decrease the risk of delinquency for children in foster care. To improve the understanding of juvenile delinquency in the child welfare system, the current study tests aspects of social control theory within the context of foster care. We focus specifically on the effects of foster parent-foster child attachment, commitment, and permanence. The results indicate that strong levels of attachment decrease the risk of delinquency for youth in foster care. Involvement with religious organizations also decreases the risk of delinquency. In contrast, perceptions of placement instability, placement with relatives, and school suspensions are associated with an increased risk of delinquency.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Renzhong; Sun, Gang; Xu, Limei, E-mail: limei.xu@pku.edu.cn
A group of materials including water and silicon exhibit many anomalous behaviors, e.g., density anomaly and diffusivity anomaly (increase upon compression). These materials are hypothesized to have a liquid-liquid phase transition (LLPT) and the critical fluctuation in the vicinity of the liquid-liquid critical point is considered as the origin of different anomalies. Liquid gallium was also reported to have a LLPT, yet whether it shows similar water-like anomalies is not yet studied. Using molecular dynamics simulations on a modified embedded-atom model, we study the thermodynamic, dynamic, and structural properties of liquid gallium as well as its LLPT. We find that,more » similar to water-like materials predicted to have the LLPT, gallium also shows different anomalous behaviors (e.g., density anomaly, diffusivity anomaly, and structural anomaly). We also find that its thermodynamic and structural response functions are continuous and show maxima in the supercritical region, the loci of which asymptotically approach to the other and merge to the Widom line. These phenomena are consistent with the supercritical phenomenon in a category of materials with a liquid-liquid critical point, which could be common features in most materials with a LLPT.« less
Dynamical properties of water-methanol solutions
NASA Astrophysics Data System (ADS)
Mallamace, Francesco; Corsaro, Carmelo; Mallamace, Domenico; Vasi, Cirino; Vasi, Sebastiano; Stanley, H. Eugene
2016-02-01
We study the relaxation times tα in the water-methanol system. We examine new data and data from the literature in the large temperature range 163 < T < 335 K obtained using different experimental techniques and focus on how tα affects the hydrogen bond structure of the system and the hydrophobicity of the alcohol methyl group. We examine the relaxation times at a fixed temperature as a function of the water molar fraction XW and observe two opposite behaviors in their curvature when the system moves from high to low T regimes. This behavior differs from that of an ideal solution in that it has excess values located at different molar fractions (XW = 0.5 for high T and 0.75 in the deep supercooled regime). We analyze the data and find that above a crossover temperature T ˜ 223 K, hydrophobicity plays a significant role and below it the water tetrahedral network dominates. This temperature is coincident with the fragile-to-strong dynamical crossover observed in confined water and supports the liquid-liquid phase transition hypothesis. At the same time, the reported data suggest that this crossover temperature (identified as the Widom line temperature) also depends on the alcohol concentration.
Tetrahedrality and hydrogen bonds in water
NASA Astrophysics Data System (ADS)
Székely, Eszter; Varga, Imre K.; Baranyai, András
2016-06-01
We carried out extensive calculations of liquid water at different temperatures and pressures using the BK3 model suggested recently [P. T. Kiss and A. Baranyai, J. Chem. Phys. 138, 204507 (2013)]. In particular, we were interested in undercooled regions to observe the propensity of water to form tetrahedral coordination of closest neighbors around a central molecule. We compared the found tetrahedral order with the number of hydrogen bonds and with the partial pair correlation functions unfolded as distributions of the closest, the second closest, etc. neighbors. We found that contrary to the number of hydrogen bonds, tetrahedrality changes substantially with state variables. Not only the number of tetrahedral arrangements increases with lowering the pressure, the density, and the temperature but the domain size of connecting tetrahedral structures as well. The difference in tetrahedrality is very pronounced between the two sides of the Widom line and even more so between the low density amorphous (LDA) and high density amorphous (HDA) phases. We observed that in liquid water and in HDA, the 5th water molecule, contrary to ice and LDA, is positioned between the first and the second coordination shell. We found no convincing evidence of structural heterogeneity or regions referring to structural transition.
Kinetics of diffusional droplet growth in a liquid/liquid two-phase system
NASA Technical Reports Server (NTRS)
Baird, James K.; Cain, Judith B.
1993-01-01
This report contains experimental results for the interdiffusion coefficient of the system, succinonitrile plus water, at a number of compositions and temperatures in the single phase region of the phase diagram. The concentration and temperature dependence of the measured diffusion coefficient has been analyzed in terms of Landau - Ginzburg theory, which assumes that the Gibb free energy is an analytic function of its variables, and can be expanded in a Taylor series about any point in the phase diagram. At most points in the single phase region this is adequate. Near the consolute point (critical point of solution), however, the free energy is non-analytic, and the Landau - Ginzburg theory fails. The solution to this problem dictates that the Landau - Ginzburg form of the free energy be replaced by Widom scaling functions with irrational values for the scaling exponents. As our measurements of the diffusion coefficient near the critical point reflect this non-analytic character, we are preparing for publication in a refereed journal a separate analysis of some of the data contained herein as well as some additional measurements we have just completed. When published, reprints of this article will be furnished to NASA.
Bilgehan, Fatma; Dilbaz, Berna; Karadag, Burak; Deveci, Canan Dura
2015-09-01
The aim of this study was to compare the safety, bleeding pattern, effects, side-effects, complications and 6-month continuity rates of levonorgestrel-bearing intrauterine system (LNG-IUS) with conventional copper intrauterine device (Cu-IUD) inserted immediately after voluntary termination of pregnancy up to 10 weeks of gestation. One hundred women who underwent voluntary pregnancy termination and preferred IUD insertion as a contraceptive method after counseling were enrolled. The patients were randomly allocated to Cu-IUD or LNG-IUS and followed up at 10 days, and at 1, 3 and 6 months. The expulsion rates, continuation rates, side-effects, and bleeding patterns were compared. Fifty women in the Cu-IUD group and 44 women in the LNG-IUS group were followed up. The continuity and expulsion rate for Cu-IUD and LNG-IUS at the end of 6 months was 74%, 12%, and 75%, 11.3%, respectively. In LNG-IUS users, the incidence of amenorrhea and the number of spotting days were higher and hemoglobin increased throughout the follow-up period. The side-effects related to both methods were not different from interval insertions. Immediate post-abortion intrauterine contraception with Cu-IUD or LNG-IUS is a safe, reliable method. The incidence of side-effects is similar, and there is only a slightly higher rate of expulsion but an acceptable rate of method continuation. © 2015 Japan Society of Obstetrics and Gynecology.
Recombinational Cloning Using Gateway and In-Fusion Cloning Schemes
Throop, Andrea L.; LaBaer, Joshua
2015-01-01
The comprehensive study of protein structure and function, or proteomics, depends on the obtainability of full-length cDNAs in species-specific expression vectors and subsequent functional analysis of the expressed protein. Recombinational cloning is a universal cloning technique based on site-specific recombination that is independent of the insert DNA sequence of interest, which differentiates this method from the classical restriction enzyme-based cloning methods. Recombinational cloning enables rapid and efficient parallel transfer of DNA inserts into multiple expression systems. This unit summarizes strategies for generating expression-ready clones using the most popular recombinational cloning technologies, including the commercially available Gateway® (Life Technologies) and In-Fusion® (Clontech) cloning technologies. PMID:25827088
Methods to Predict Stresses in Cutting Inserts Brazed Using Iron-Carbon Brazing Alloy
NASA Astrophysics Data System (ADS)
Konovodov, V. V.; Valentov, A. V.; Retuynskiy, O. Yu; Esekuev, Sh B.
2016-04-01
This work describes a method for predicting residual and operating stresses in a flat-form tool insert made of tungsten free carbides brazed using iron-carbon alloy. According to the studies’ results it is concluded that the recommendations relating to the limitation of a melting point of tool brazing alloys (950-1100°C according to different data) are connected with a negative impact on tools as a composite made of dissimilar materials rather than on hard alloys as a tool material. Due to the cooling process stresses inevitably occur in the brazed joint of dissimilar materials, and these stresses increase with the higher solidification temperature of the brazing alloy.
Method and apparatus for duct sealing using a clog-resistant insertable injector
Wang, Duo; Modera, Mark P.
2007-01-02
A clog-resistant injector spray nozzle allows relatively unobtrusive insertion through a small access aperture into existing ductwork in occupied buildings for atomized particulate sealing of a ductwork. The spray nozzle comprises an easily cleaned and easily replaced straight liquid tube whose liquid contents are principally propelled by a heated propellant gas, such as heated air. Heat transfer is minimized from the heated propellant gas to the liquid tube until they both exit the injector, thereby greatly reducing the likelihood of nozzle clogging. A method of duct sealing using particles driven by heated propellant gas is described, whereby duct-sealing operations become both faster, and commercially practicable in inhabited commercial and residential buildings.
Loeffler, Troy D; Sepehri, Aliasghar; Chen, Bin
2015-09-08
Reformulation of existing Monte Carlo algorithms used in the study of grand canonical systems has yielded massive improvements in efficiency. Here we present an energy biasing scheme designed to address targeting issues encountered in particle swap moves using sophisticated algorithms such as the Aggregation-Volume-Bias and Unbonding-Bonding methods. Specifically, this energy biasing scheme allows a particle to be inserted to (or removed from) a region that is more acceptable. As a result, this new method showed a several-fold increase in insertion/removal efficiency in addition to an accelerated rate of convergence for the thermodynamic properties of the system.
NASA Astrophysics Data System (ADS)
Rochman, Auliya Noor; Prasetyo, Hari; Nugroho, Munajat Tri
2017-06-01
Vehicle Routing Problem (VRP) often occurs when the manufacturers need to distribute their product to some customers/outlets. The distribution process is typically restricted by the capacity of the vehicle and the working hours at the distributor. This type of VRP is also known as Capacitated Vehicle Routing Problem with Time Windows (CVRPTW). A Biased Random Key Genetic Algorithm (BRKGA) was designed and coded in MATLAB to solve the CVRPTW case of soft drink distribution. The standard BRKGA was then modified by applying chromosome insertion into the initial population and defining chromosome gender for parent undergoing crossover operation. The performance of the established algorithms was then compared to a heuristic procedure for solving a soft drink distribution. Some findings are revealed (1) the total distribution cost of BRKGA with insertion (BRKGA-I) results in a cost saving of 39% compared to the total cost of heuristic method, (2) BRKGA with the gender selection (BRKGA-GS) could further improve the performance of the heuristic method. However, the BRKGA-GS tends to yield worse results compared to that obtained from the standard BRKGA.
Method to Reduce Target Motion Through Needle-Tissue Interactions.
Oldfield, Matthew J; Leibinger, Alexander; Seah, Tian En Timothy; Rodriguez Y Baena, Ferdinando
2015-11-01
During minimally invasive surgical procedures, it is often important to deliver needles to particular tissue volumes. Needles, when interacting with a substrate, cause deformation and target motion. To reduce reliance on compensatory intra-operative imaging, a needle design and novel delivery mechanism is proposed. Three-dimensional finite element simulations of a multi-segment needle inserted into a pre-existing crack are presented. The motion profiles of the needle segments are varied to identify methods that reduce target motion. Experiments are then performed by inserting a needle into a gelatine tissue phantom and measuring the internal target motion using digital image correlation. Simulations indicate that target motion is reduced when needle segments are stroked cyclically and utilise a small amount of retraction instead of being held stationary. Results are confirmed experimentally by statistically significant target motion reductions of more than 8% during cyclic strokes and 29% when also incorporating retraction, with the same net insertion speed. By using a multi-segment needle and taking advantage of frictional interactions on the needle surface, it is demonstrated that target motion ahead of an advancing needle can be substantially reduced.
Fabrication of a Micro-Needle Array Electrode by Thermal Drawing for Bio-Signals Monitoring
Ren, Lei; Jiang, Qing; Chen, Keyun; Chen, Zhipeng; Pan, Chengfeng; Jiang, Lelun
2016-01-01
A novel micro-needle array electrode (MAE) fabricated by thermal drawing and coated with Ti/Au film was proposed for bio-signals monitoring. A simple and effective setup was employed to form glassy-state poly (lactic-co-glycolic acid) (PLGA) into a micro-needle array (MA) by the thermal drawing method. The MA was composed of 6 × 6 micro-needles with an average height of about 500 μm. Electrode-skin interface impedance (EII) was recorded as the insertion force was applied on the MAE. The insertion process of the MAE was also simulated by the finite element method. Results showed that MAE could insert into skin with a relatively low compression force and maintain stable contact impedance between the MAE and skin. Bio-signals, including electromyography (EMG), electrocardiography (ECG), and electroencephalograph (EEG) were also collected. Test results showed that the MAE could record EMG, ECG, and EEG signals with good fidelity in shape and amplitude in comparison with the commercial Ag/AgCl electrodes, which proves that MAE is an alternative electrode for bio-signals monitoring. PMID:27322278
Fabrication of a Micro-Needle Array Electrode by Thermal Drawing for Bio-Signals Monitoring.
Ren, Lei; Jiang, Qing; Chen, Keyun; Chen, Zhipeng; Pan, Chengfeng; Jiang, Lelun
2016-06-17
A novel micro-needle array electrode (MAE) fabricated by thermal drawing and coated with Ti/Au film was proposed for bio-signals monitoring. A simple and effective setup was employed to form glassy-state poly (lactic-co-glycolic acid) (PLGA) into a micro-needle array (MA) by the thermal drawing method. The MA was composed of 6 × 6 micro-needles with an average height of about 500 μm. Electrode-skin interface impedance (EII) was recorded as the insertion force was applied on the MAE. The insertion process of the MAE was also simulated by the finite element method. Results showed that MAE could insert into skin with a relatively low compression force and maintain stable contact impedance between the MAE and skin. Bio-signals, including electromyography (EMG), electrocardiography (ECG), and electroencephalograph (EEG) were also collected. Test results showed that the MAE could record EMG, ECG, and EEG signals with good fidelity in shape and amplitude in comparison with the commercial Ag/AgCl electrodes, which proves that MAE is an alternative electrode for bio-signals monitoring.
NASA Astrophysics Data System (ADS)
Robins, Marthony; Solomon, Justin; Sahbaee, Pooyan; Sedlmair, Martin; Choudhury, Kingshuk Roy; Pezeshk, Aria; Sahiner, Berkman; Samei, Ehsan
2017-09-01
Virtual nodule insertion paves the way towards the development of standardized databases of hybrid CT images with known lesions. The purpose of this study was to assess three methods (an established and two newly developed techniques) for inserting virtual lung nodules into CT images. Assessment was done by comparing virtual nodule volume and shape to the CT-derived volume and shape of synthetic nodules. 24 synthetic nodules (three sizes, four morphologies, two repeats) were physically inserted into the lung cavity of an anthropomorphic chest phantom (KYOTO KAGAKU). The phantom was imaged with and without nodules on a commercial CT scanner (SOMATOM Definition Flash, Siemens) using a standard thoracic CT protocol at two dose levels (1.4 and 22 mGy CTDIvol). Raw projection data were saved and reconstructed with filtered back-projection and sinogram affirmed iterative reconstruction (SAFIRE, strength 5) at 0.6 mm slice thickness. Corresponding 3D idealized, virtual nodule models were co-registered with the CT images to determine each nodule’s location and orientation. Virtual nodules were voxelized, partial volume corrected, and inserted into nodule-free CT data (accounting for system imaging physics) using two methods: projection-based Technique A, and image-based Technique B. Also a third Technique C based on cropping a region of interest from the acquired image of the real nodule and blending it into the nodule-free image was tested. Nodule volumes were measured using a commercial segmentation tool (iNtuition, TeraRecon, Inc.) and deformation was assessed using the Hausdorff distance. Nodule volumes and deformations were compared between the idealized, CT-derived and virtual nodules using a linear mixed effects regression model which utilized the mean, standard deviation, and coefficient of variation (Mea{{n}RHD} , ST{{D}RHD} and C{{V}RHD}{) }~ of the regional Hausdorff distance. Overall, there was a close concordance between the volumes of the CT-derived and virtual nodules. Percent differences between them were less than 3% for all insertion techniques and were not statistically significant in most cases. Correlation coefficient values were greater than 0.97. The deformation according to the Hausdorff distance was also similar between the CT-derived and virtual nodules with minimal statistical significance in the (C{{V}RHD} ) for Techniques A, B, and C. This study shows that both projection-based and image-based nodule insertion techniques yield realistic nodule renderings with statistical similarity to the synthetic nodules with respect to nodule volume and deformation. These techniques could be used to create a database of hybrid CT images containing nodules of known size, location and morphology.
Robins, Marthony; Solomon, Justin; Sahbaee, Pooyan; Sedlmair, Martin; Choudhury, Kingshuk Roy; Pezeshk, Aria; Sahiner, Berkman; Samei, Ehsan
2017-01-01
Virtual nodule insertion paves the way towards the development of standardized databases of hybrid CT images with known lesions. The purpose of this study was to assess three methods (an established and two newly developed techniques) for inserting virtual lung nodules into CT images. Assessment was done by comparing virtual nodule volume and shape to the CT-derived volume and shape of synthetic nodules. 24 synthetic nodules (three sizes, four morphologies, two repeats) were physically inserted into the lung cavity of an anthropomorphic chest phantom (KYOTO KAGAKU). The phantom was imaged with and without nodules on a commercial CT scanner (SOMATOM Definition Flash, Siemens) using a standard thoracic CT protocol at two dose levels (1.4 and 22 mGy CTDIvol). Raw projection data were saved and reconstructed with filtered back-projection and sinogram affirmed iterative reconstruction (SAFIRE, strength 5) at 0.6 mm slice thickness. Corresponding 3D idealized, virtual nodule models were co-registered with the CT images to determine each nodule’s location and orientation. Virtual nodules were voxelized, partial volume corrected, and inserted into nodule-free CT data (accounting for system imaging physics) using two methods: projection-based Technique A, and image-based Technique B. Also a third Technique C based on cropping a region of interest from the acquired image of the real nodule and blending it into the nodule-free image was tested. Nodule volumes were measured using a commercial segmentation tool (iNtuition, TeraRecon, Inc.) and deformation was assessed using the Hausdorff distance. Nodule volumes and deformations were compared between the idealized, CT-derived and virtual nodules using a linear mixed effects regression model which utilized the mean, standard deviation, and coefficient of variation (MeanRHD, and STDRHD CVRHD) of the regional Hausdorff distance. Overall, there was a close concordance between the volumes of the CT-derived and virtual nodules. Percent differences between them were less than 3% for all insertion techniques and were not statistically significant in most cases. Correlation coefficient values were greater than 0.97. The deformation according to the Hausdorff distance was also similar between the CT-derived and virtual nodules with minimal statistical significance in the (CVRHD) for Techniques A, B, and C. This study shows that both projection-based and image-based nodule insertion techniques yield realistic nodule renderings with statistical similarity to the synthetic nodules with respect to nodule volume and deformation. These techniques could be used to create a database of hybrid CT images containing nodules of known size, location and morphology. PMID:28786399
Oguntunde, Olugbenga; Orobaton, Nosa; Otolorin, Emmanuel; Inuwa, Fatima; Alalade, Olubisi; Abegunde, Dele; Danladi, Saba’atu
2015-01-01
Background: Contraceptive use remains low in Nigeria, with only 11% of women reporting use of any modern method. Access to long-acting reversible contraceptives (LARCs) is constrained by a severe shortage of human resources. To assess feasibility of task shifting provision of implants, we trained community health extension workers (CHEWs) to insert and remove contraceptive implants in rural communities of Bauchi and Sokoto states in northern Nigeria. Methods: We conducted 2- to 3-week training sessions for 166 selected CHEWs from 82 facilities in Sokoto state (September 2013) and 84 health facilities in Bauchi state (December 2013). To assess feasibility of the task shifting approach, we conducted operations research using a pretest–posttest design using multiple sources of information, including surveys with 151 trained CHEWs (9% were lost to follow-up) and with 150 family planning clients; facility observations using supply checklists (N = 149); direct observation of counseling provided by CHEWs (N = 144) and of their clinical (N = 113) skills; as well as a review of service statistics (N = 151 health facilities). The endline assessment was conducted 6 months after the training in each state. Results: CHEWs inserted a total of 3,588 implants in 151 health facilities over a period of 6 months, generating 10,088 couple-years of protection (CYP). After practicing on anatomic arm models, most CHEWs achieved competency in implant insertions after insertions with 4–5 actual clients. Clinical observations revealed that CHEWs performed implant insertion tasks correctly 90% of the time or more for nearly all checklist items. The amount of information that CHEWs provided clients increased between baseline and endline, and over 95% of surveyed clients reported being satisfied with CHEWs’ services in both surveys. The study found that supervisors not only observed and corrected insertion skills, as needed, during supervisory visits but also encouraged CHEWs to conduct more community mobilization to generate client demand, thereby promoting access to quality services. CHEWs identified a lack of demand in the communities as the major barrier for providing services. Conclusion: With adequate training and supportive supervision, CHEWs in northern Nigeria can provide high-quality implant insertion services. If more CHEWs are trained to provide implants and greater community outreach is conducted to generate demand, uptake of LARCs in Nigeria may increase. PMID:26374800
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miller, Bethany H. T., E-mail: bmiller@doctors.org.uk; Griffiths, Ewen A., E-mail: Eagriffiths@doctors.org.uk; Pursnani, Kishore G., E-mail: Kish.Pursnani@lthtr.nhs.uk
2013-12-15
IntroductionSelf-expanding metallic stents (SEMS) are used to palliate malignant gastric outlet obstruction (GOO) and are useful in patients with limited life expectancy or severe medical comorbidity, which would preclude surgery. Stenting can be performed transorally or by a percutaneous transgastric technique. Our goal was to review the outcome of patients who underwent radiological SEMS insertion performed by a single consultant interventional radiologist. Methods: Patients were identified from a prospectively collected database held by one consultant radiologist. Data were retrieved from radiological reports, multidisciplinary team meetings, and the patients' case notes. Univariate survival analysis was performed. Results: Between December 2000 andmore » January 2011, 100 patients (63 males, 37 females) had 110 gastroduodenal stenting procedures. Median age was 73 (range 39-89) years. SEMS were inserted transorally (n = 66) or transgastrically (n = 44). Site of obstruction was the stomach (n = 37), duodenum (n = 50), gastric pull-up (n = 10), or gastroenterostomy (n = 13). Seven patients required biliary stents. Technical success was 86.4 %: 83.3 % for transoral insertion, 90.9 % for transgastric insertion. Eleven patients developed complications. Median GOO severity score: 1 pre-stenting, 2 post-stenting (p = 0.0001). Median survival was 54 (range 1-624) days. Post-stenting GOO severity score was predictive of survival (p = 0.0001). Conclusions: The technical success rate for insertion of palliative SEMS is high. Insertional technique can be tailored to the individual depending on the location of the tumor and whether it is possible to access the stomach percutaneously. Patients who have successful stenting and return to eating a soft/normal diet have a statistically significant increase in survival.« less
Donders, Gilbert Gerard Ghislain; Bellen, G; Ruban, Kateryna; Van Bulck, Ben
2018-03-01
Recurrent vulvovaginal infections are a frequent complaint in young women in need of contraception. However, the influence of the contraceptive method on the course of the disease is not well known. To investigate the influence of the levonorgestrel-releasing intrauterine-system (LNG-IUS) on the vaginal microflora. Short-term (3 months) and long-term (1 to 5 years) changes of vaginal microbiota were compared with pre-insertion values in 252 women presenting for LNG-IUS insertion. Detailed microscopy on vaginal fluid was used to define lactobacillary grades (LBGs), bacterial vaginosis (BV), aerobic vaginitis (AV) and the presence of Candida. Cultures for enteric aerobic bacteria and Candida were used to back up the microscopy findings. Fisher's test was used to compare vaginal microbiome changes pre- and post-insertion. Compared to the pre-insertion period, we found a temporary worsening in LBGs and increased rates of BV and AV after 3 months of LNG-IUS. After 1 and 5 years, however, these changes were reversed, with a complete restoration to pre-insertion levels. Candida increased significantly after long-term carriage of LNG-IUS compared to the period before insertion [OR 2.0 (CL951.1-3.5), P=0.017]. Short-term use of LNG-IUS temporarily decreases lactobacillary dominance, and increases LBG, AV and BV, but after 1 to 5 years these characteristics return to pre-insertion levels, reducing the risk of complications to baseline levels. Candida colonization, on the other hand, is twice as high after 1 to 5 years of LNG-IUS use, making it less indicated for long-term use in patients with or at risk for recurrent vulvovaginal candidosis.
Sánchez, Jorge; Sal y Rosas, Victor G.; Hughes, James P.; Baeten, Jared M.; Fuchs, Jonathan; Buchbinder, Susan P.; Koblin, Beryl A.; Casapia, Martín; Ortiz, Abner; Celum, Connie
2011-01-01
Objectives To assess the association between male circumcision, insertive anal sex practices, and HIV acquisition in a cohort of men who have sex with men (MSM). Methods Data were from 1824 HSV-2 seropositive, HIV seronegative MSM, 1362 (75%) from Peru and 462 (25%) from the US, who participated in a randomized placebo controlled trial of HSV-2 suppression for HIV prevention (HPTN 039). Circumcision status was determined by examination at enrollment. HIV testing was done every three months for up to 18 months. Partner-specific sexual behavior for up to the last three partners during the previous three months was analyzed. Results There was no significant association between male circumcision and HIV acquisition in univariate analysis (RR=0.84, 95% CI 0.50–1.42). In a pre-specified multivariate analysis that assumed a linear relationship between the proportion of insertive acts and effect of circumcision on HIV acquisition, the interaction between circumcision and proportion of insertive acts was not significant (p=0.11). In an exploratory analysis that categorized behavior with recent partners by proportion of insertive acts (<60% or ≥60% insertive acts), circumcision was associated with a non-statistically significant 69% reduction in the risk of HIV acquisition (RR=0.31, 95% CI 0.06–1.51) among men who reported ≥60% of insertive acts with recent male partners. Conclusion Circumcision does not have a significant protective effect against HIV acquisition among MSM from Peru and US, although there may be reduced risk for men who are primarily insertive with their male partners. This association needs to be investigated across diverse cohorts of MSM. PMID:21099672
Dietz, Aarno; Gazibegovic, Dzemal; Tervaniemi, Jyrki; Vartiainen, Veli-Matti; Löppönen, Heikki
2016-12-01
The aim of this study was to evaluate the insertion results and placement of the new Advanced Bionics HiFocus Mid-Scala (HFms) electrode array, inserted through the round window membrane, in eight fresh human temporal bones using cone beam computed tomography (CBCT). Pre- and post-insertion CBCT scans were registered to create a 3D reconstruction of the cochlea with the array inserted. With an image fusion technique both the bony edges of the cochlea and the electrode array in situ could accurately be determined, thus enabling to identify the exact position of the electrode array within the scala tympani. Vertical and horizontal scalar location was measured at four points along the cochlea base at an angular insertion depth of 90°, 180° and 270° and at electrode 16, the most basal electrode. Smooth insertion through the round window membrane was possible in all temporal bones. The imaging results showed that there were no dislocations from the scala tympani into the scala vestibule. The HFms electrode was positioned in the middle of the scala along the whole electrode array in three out of the eight bones and in 62 % of the individual locations measured along the base of the cochlea. In only one cochlea a close proximity of the electrode with the basilar membrane was observed, indicating possible contact with the basilar membrane. The results and assessments presented in this study appear to be highly accurate. Although a further validation including histopathology is needed, the image fusion technique described in this study represents currently the most accurate method for intracochlear electrode assessment obtainable with CBCT.
Zaballos, Matilde; Bastida, Emilia; Agustí, Salomé; Portas, Maite; Jiménez, Consuelo; López-Gil, Maite
2015-10-06
A new supraglottic device, the LMA-Supreme™, has recently become available for clinical use. Information on anaesthetic and co-adjuvant requirements for insertion of the LMA-Supreme™ is limited. The present study aimed to evaluate the optimal effect-site concentration of propofol in 50 % (EC50) of adults necessary for successful insertion of the LMA-Supreme™ and to examine remifentanil's effect on propofol requirements. Fifty-eight elective patients (aged 18-60 years; ASA (American Society Anaesthesiologists) physical status classification I and II) scheduled for day surgery were randomly assigned to one of two groups: propofol with saline or propofol with remifentanil. Anaesthesia was induced by target-controlled infusion according to predetermined effect-site concentrations of propofol and remifentanil (5 ng.mL(-1)). The EC50 was calculated using Dixon's up-and-down method. Ten minutes following drug administration, LMA-Supreme™ insertion was attempted without the use of muscle relaxant drugs. In the propofol + saline group, the EC50 of propofol required for LMA-Supreme™ insertion was 6.32 ± 0.67 μg.mL(-1) (95 % CI, 5.69-6.94 μg.mL(-1)). With the addition of remifentanil at an effect-site concentration of 5 ng.mL(-1), the EC50 of propofol required for LMA-Supreme™ insertion was 2.50 ± 0.80 μg.mL(-1) (95 % CI, 1.82-3.17 μg.mL(-1); p < 0.0001). The propofol requirement for smooth insertion of the LMA-Supreme™ was 60 % less when remifentanil (5 ng.mL(-1)) was co-administered. Identified as NCT01974648 at www.clinicaltrials.gov .
Large Genomic Fragment Deletions and Insertions in Mouse Using CRISPR/Cas9
Satheka, Achim Cchitvsanzwhoh; Togo, Jacques; An, Yao; Humphrey, Mabwi; Ban, Luying; Ji, Yan; Jin, Honghong; Feng, Xuechao; Zheng, Yaowu
2015-01-01
ZFN, TALENs and CRISPR/Cas9 system have been used to generate point mutations and large fragment deletions and insertions in genomic modifications. CRISPR/Cas9 system is the most flexible and fast developing technology that has been extensively used to make mutations in all kinds of organisms. However, the most mutations reported up to date are small insertions and deletions. In this report, CRISPR/Cas9 system was used to make large DNA fragment deletions and insertions, including entire Dip2a gene deletion, about 65kb in size, and β-galactosidase (lacZ) reporter gene insertion of larger than 5kb in mouse. About 11.8% (11/93) are positive for 65kb deletion from transfected and diluted ES clones. High targeting efficiencies in ES cells were also achieved with G418 selection, 46.2% (12/26) and 73.1% (19/26) for left and right arms respectively. Targeted large fragment deletion efficiency is about 21.4% of live pups or 6.0% of injected embryos. Targeted insertion of lacZ reporter with NEO cassette showed 27.1% (13/48) of targeting rate by ES cell transfection and 11.1% (2/18) by direct zygote injection. The procedures have bypassed in vitro transcription by directly co-injection of zygotes or co-transfection of embryonic stem cells with circular plasmid DNA. The methods are technically easy, time saving, and cost effective in generating mouse models and will certainly facilitate gene function studies. PMID:25803037
A virtual reality based simulator for learning nasogastric tube placement.
Choi, Kup-Sze; He, Xuejian; Chiang, Vico Chung-Lim; Deng, Zhaohong
2015-02-01
Nasogastric tube (NGT) placement is a common clinical procedure where a plastic tube is inserted into the stomach through the nostril for feeding or drainage. However, the placement is a blind process in which the tube may be mistakenly inserted into other locations, leading to unexpected complications or fatal incidents. The placement techniques are conventionally acquired by practising on unrealistic rubber mannequins or on humans. In this paper, a virtual reality based training simulation system is proposed to facilitate the training of NGT placement. It focuses on the simulation of tube insertion and the rendering of the feedback forces with a haptic device. A hybrid force model is developed to compute the forces analytically or numerically under different conditions, including the situations when the patient is swallowing or when the tube is buckled at the nostril. To ensure real-time interactive simulations, an offline simulation approach is adopted to obtain the relationship between the insertion depth and insertion force using a non-linear finite element method. The offline dataset is then used to generate real-time feedback forces by interpolation. The virtual training process is logged quantitatively with metrics that can be used for assessing objective performance and tracking progress. The system has been evaluated by nursing professionals. They found that the haptic feeling produced by the simulated forces is similar to their experience during real NGT insertion. The proposed system provides a new educational tool to enhance conventional training in NGT placement. Copyright © 2014 Elsevier Ltd. All rights reserved.
Occurence of adverse events due to continuous glucose monitoring.
Jadviscokova, Tereza; Fajkusova, Zuzana; Pallayova, Maria; Luza, Jiri; Kuzmina, Galina
2007-12-01
Continuous glucose monitoring (CGM) using transcutaneous sensors is becoming a sophisticated method to control and regulate glucose metabolism. The transcutaneous sensor of the CGM system (CGMS Medtronic Minimed, Northridge, CA, USA) is chosen to measure glucose concentration in interstitial fluid up to three days after insertion even though its function remains stable for a longer period. The question arises, which factors really limit the period of sensor insertion without unnecessary risk. The aim of this study was to assess any adverse events occurring in the course of 9 days after the sensor insertion. In a group of 22 healthy volunteers aged 21.8+/-1.30 y (mean +/- SE) a total of 26 sensors was inserted subcutaneously in gluteal or lumbar region for 9 days. Before insertion the site was sprayed with an antiseptic (Cutasept F, Bode Chemie, Hamburg, Germany). Local adverse reactions and disturbances in general condition were examined. In the course of 184 sensor-days, there were only minor local adverse events: hypersensitivity, itching, pain, redness, burning, subcutaneous hemorrhage. Additionally, sleep disturbances, attention deficits, problems related to the CGMS monitor, to adhesive tape and/or sensor were found. None of these resulted in sensor withdrawal. In 12 volunteers (55 %) no complications were observed. The sensor function measured according to electrical signals (ISIG) failed (always on day 1-2) in 4 cases (16 %). The present FDA approved 3-day insertion period for Medtronic transcutaneous sensor does not seem to limit its use and appears to be worth a careful revision.
Method and apparatus for assembling solid oxide fuel cells
Szreders, Bernard E.; Campanella, Nicholas
1989-01-01
A plurality of jet air tubes are supported and maintained in a spaced matrix array by a positioning/insertion assembly for insertion in respective tubes of a solid oxide fuel cell (SOFC) in the assembly of an SOFC module. The positioning/insertion assembly includes a plurality of generally planar, elongated, linear vanes which are pivotally mounted at each end thereof to a support frame. The vanes, which each include a plurality of spaced slots along the facing edges thereof, may be pivotally displaced from a generally vertical orientation, wherein each jet air tube is positioned within and engaged by the aligned slots of a plurality of paired upper and lower vanes to facilitate their insertion in respective aligned SOFC tubes arranged in a matrix array, to an inclined orientation, wherein the jet air tubes may be removed from the positioning/insertion assembly after being inserted in the SOFC tubes. A rectangular compression assembly of adjustable size is adapted to receive and squeeze a matrix of SOFC tubes so as to compress the inter-tube nickel felt conductive pads which provide series/parallel electrical connection between adjacent SOFCs, with a series of increasingly larger retainer frames used to maintain larger matrices of SOFC tubes in position. Expansion of the SOFC module housing at the high operating temperatures of the SOFC is accommodated by conductive, flexible, resilient expansion, connector bars which provide support and electrical coupling at the top and bottom of the SOFC module housing.
Suer, Berkay Tolga; Yaman, Zekai; Buyuksarac, Bora
2016-01-01
Fractal analysis is a mathematical method used to describe the internal architecture of complex structures such as trabecular bone. Fractal analysis of panoramic radiographs of implant recipient sites could help to predict the quality of the bone prior to implant placement. This study investigated the correlations between the fractal dimension values obtained from panoramic radiographs and the insertion torque and resonance frequency values of mandibular implants. Thirty patients who received a total of 55 implants of the same brand, diameter, and length in the mandibular premolar and molar regions were included in the study. The same surgical procedures were applied to each patient, and the insertion torque and resonance frequency values were recorded for each implant at the time of placement. The radiographic fractal dimensions of the alveolar bone in the implant recipient area were calculated from preoperative panoramic radiographs using a box-counting algorithm. The insertion torque and resonance frequency values were compared with the fractal dimension values using the Spearman test. All implants were successful, and none were lost during the follow-up period. Linear correlations were observed between the fractal dimension and resonance frequency, between the fractal dimension and insertion torque, and between resonance frequency and insertion torque. These results suggest that the noninvasive measurement of the fractal dimension from panoramic radiographs might help to predict the bone quality, and thus the primary stability of dental implants, before implant surgery.
IUD knowledge and experience among family medicine residents.
Schubert, Finn D; Herbitter, Cara; Fletcher, Jason; Gold, Marji
2015-06-01
The intrauterine device (IUD) is a highly effective contraceptive method with few contraindications; however, clinician lack of training in insertion and misconceptions about IUD risks are barriers to utilization. Previous research has shown gaps in IUD training in family medicine residency programs. An online survey addressing experience with IUD insertion, knowledge of patient eligibility and IUD risks, and intent to insert IUDs in practice was circulated to residents at 15 US family medicine residency programs. Programs were eligible to participate if they were receiving funding to enhance training in family planning and abortion care and interested in additional support to enhance IUD training. The overall response rate for the surveys was 76.1% (332/436). Experience with the levonorgestrel intrauterine system was more common than with the copper IUD. Residents performed well on knowledge questions, but many would not insert in common patient scenarios in which insertion was not contraindicated, including a history of sexually transmitted infection in the past 6 months (48.2% would not insert), a history of ectopic pregnancy (37.0%), no pap smear in the past year (30.7%), or if the patient was not in a monogamous relationship (29.2%). The vast majority of residents (88.7%) reported that they were likely or very likely to provide IUDs in their future family medicine practice. Although residents overwhelmingly expressed interest in providing IUDs after residency, our results suggest that additional clinical and didactic training is needed, particularly interventions targeted at dispelling misconceptions about patient eligibility for IUDs.
Kato, Hirokazu; Kondo, Motoharu; Imada, Hajime; Kuroda, Masahiro; Kamimura, Yoshitsugu; Saito, Kazuyuki; Kuroda, Kagayaki; Ito, Koichi; Takahashi, Hideaki; Matsuki, Hidetoshi
2013-05-01
This article is a redissemination of the previous Japanese Quality Assurance Guide guidelines. Specific absorption rate and temperature distribution were investigated with respect to various aspects including metallic implant size and shape, insertion site, insertion direction, blood flow and heating power, and simulated results were compared with adverse reactions of patients treated by radio frequency capacitive-type heating. Recommended guidelines for safe heating methods for patients with metallic implants are presented based on our findings.
Briggs, R J; Tykocinski, M; Saunders, E; Hellier, W; Dahm, M; Pyman, B; Clark, G M
2001-09-01
To review the mechanisms and nature of intracochlear damage associated with cochlear implant electrode array insertion, in particular, the various perimodiolar electrode designs. Make recommendations regarding surgical techniques for the Nucleus Contour electrode to ensure correct position and minimal insertion trauma. The potential advantages of increased modiolar proximity of intracochlear multichannel electrode arrays are a reduction in stimulation thresholds, an increase in dynamic range and more localized neural excitation. This may improve speech perception and reduce power consumption. These advantages may be negated if increased intracochlear damage results from the method used to position the electrodes close to the modiolus. A review of the University of Melbourne Department of Otolaryngology experience with temporal bone safety studies using the Nucleus standard straight electrode array and a variety of perimodiolar electrode array designs; comparison with temporal bone insertion studies from other centres and postmortem histopathology studies reported in the literature. Review of our initial clinical experience using the Nucleus Contour electrode array. The nature of intracochlear damage resulting from electrode insertion trauma ranges from minor, localized, spiral ligament tear to diffuse organ of Corti disruption and osseous spiral lamina fracture. The type of damage depends on the mechanical characteristics of the electrode array, the stiffness, curvature and size of the electrode in relation to the scala, and the surgical technique. The narrow, flexible, straight arrays are the least traumatic. Pre-curved or stiffer arrays are associated with an incidence of basilar membrane perforation. The cochleostomy must be correctly sited in relation to the round window to ensure scala tympani insertion. A cochleostomy anterior to the round window rather than inferior may lead to scala media or scala vestibuli insertion. Proximity of electrodes to the modiolus can be achieved without intracochlear damage provided the electrode array is a free fit within the scala, of appropriate size and shape, and accurate scala tympani insertion is performed.
Thrasher, James F.; Swayampakala, Kamala; Cummings, K. Michael; Hammond, David; Anshari, Dien; Krugman, Dean M.; Hardin, James W.
2016-01-01
Background In June 2012, Canada implemented new pictorial warnings on cigarette packages, along with package inserts with messages to promote response efficacy (i.e., perceived quitting benefits) and self-efficacy (i.e., confidence to quit). This study assessed smokers’ attention towards warnings and inserts and its relationship with efficacy beliefs, risk perceptions and cessation at follow-up. Methods Data were analysed in 2015 from a prospective online consumer panel of adult Canadian smokers surveyed every four months between September 2012 and September 2014. Generalized Estimating Equation models assessed associations between reading inserts, reading warnings and efficacy beliefs (self-efficacy, response efficacy), risk perceptions, quit attempts of any length, and sustained quit attempts (i.e., 30 days or more) at follow-up. Models adjusted for socio-demographics, smoking-related variables, and time-in-sample effects. Results Over the study period, reading warnings significantly decreased (p<0.0001) while reading inserts increased (p=0.004). More frequent reading of warnings was associated independently with stronger response efficacy (Boften/very often vs never=0.28, 95% CI: 0.11–0.46) and risk perceptions at follow-up (Boften/very often vs never=0.31, 95% CI: 0.06–0.56). More frequent reading of inserts was associated independently with stronger self-efficacy to quit at follow-up (Btwice or more vs none=0.30, 95% CI: 0.14–0.47), quit attempts (ORtwice or more vs none= 1.68, 95% CI: 1.28–2.19), and quit attempts lasting 30 days or longer (ORtwice or more vs none=1.48, 95% CI: 1.01 – 2.17). Conclusions More frequent reading of inserts was associated with self-efficacy to quit, quit attempts, and sustained quitting at follow-up, suggesting that inserts complement pictorial HWLs. PMID:26970037
Evaluation of a silicon photomultiplier PET insert for simultaneous PET and MR imaging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ko, Guen Bae; Kim, Kyeong Yun; Yoon, Hyun Suk
2016-01-15
Purpose: In this study, the authors present a silicon photomultiplier (SiPM)-based positron emission tomography (PET) insert dedicated to small animal imaging with high system performance and robustness to temperature change. Methods: The insert consists of 64 LYSO-SiPM detector blocks arranged in 4 rings of 16 detector blocks to yield a ring diameter of 64 mm and axial field of view of 55 mm. Each detector block consists of a 9 × 9 array of LYSO crystals (1.2 × 1.2 × 10 mm{sup 3}) and a monolithic 4 × 4 SiPM array. The temperature of each monolithic SiPM is monitored, andmore » the proper bias voltage is applied according to the temperature reading in real time to maintain uniform performance. The performance of this PET insert was characterized using National Electrical Manufacturers Association NU 4-2008 standards, and its feasibility was evaluated through in vivo mouse imaging studies. Results: The PET insert had a peak sensitivity of 3.4% and volumetric spatial resolutions of 1.92 (filtered back projection) and 0.53 (ordered subset expectation maximization) mm{sup 3} at center. The peak noise equivalent count rate and scatter fraction were 42.4 kcps at 15.08 MBq and 16.5%, respectively. By applying the real-time bias voltage adjustment, an energy resolution of 14.2% ± 0.3% was maintained and the count rate varied ≤1.2%, despite severe temperature changes (10–30 °C). The mouse imaging studies demonstrate that this PET insert can produce high-quality images useful for imaging studies on the small animals. Conclusions: The developed MR-compatible PET insert is designed for insertion into a narrow-bore magnetic resonance imaging scanner, and it provides excellent imaging performance for PET/MR preclinical studies.« less
Shin, Sung Joon; Lee, Ji-Ho; Lee, Jae Hyup
2017-07-01
A prospective, within-patient, left-right comparative study. To evaluate the efficacy of hydroxyapatite (HA) stick augmentation method by comparing the insertional torque of the pedicle screw in osteoporotic and nonosteoporotic patients. Unsatisfactory clinical outcomes after spine surgery in osteoporotic patients are related to pedicle screw loosening or pull-outs. HA, as a bone graft extender, has a possibility to enhance the fixation strength at the bone-screw interface. From November 2009 to December 2010, among patients who required bilateral pedicle screw fixation for lumbar spine surgery, 22 patients were enrolled, who recieved unilateral HA stick augmentation and completed intraoperative insertional torque measurement of each pedicle screws. On the basis of preoperative evaluation of bone mineral density, patients with osteoporosis had 2 HA sticks inserted unilaterally, and 1 stick for patients without osteoporosis. Pedicle screw loosening and pull-outs were assessed using 12-month postoperative CT scans and follow-up radiographs. Clinical evaluation was done preoperatively and at 1 year postoperatively, based on Visual Analog Scale score, Oswestry Disability Index, and Short Form-36 Health Survey. Regardless of bone mineral density, the average torque value of all pedicle screws with HA stick insertion (HA stick inserted group) was significantly higher than that of all pedicle screws without HA insertion (control group) (P<0.0001). Same results were seen in the HA stick inserted subgroups and the control subgroups within both of the osteoporosis group (P=0.009) and the nonosteoporosis group (P=0.0004). There was no statistically significant difference of the rate of pedicle screw loosening in between the HA stick inserted group and the control group. Clinical evaluation also showed no statistically significant difference in between patients with loosening and those without. The enhancement of initial pedicle screw fixation strength in osteoporotic patients can be achieved by HA stick augmentation.
Microleakage of Posterior Composite Restorations with Fiber Inserts Using two Adhesives after ging
Sharafeddin, F; Yousefi, H; Modiri, Sh; Tondari, A; Safaee Jahromi, SR
2013-01-01
Statement of Problem: Microleakage is one of the most frequent problems associated with resin composites, especially at the gingival margin of posterior restorations. Insertion of fibers in composite restorations can reduce the total amount of composite and help to decrease the shrinkage. Purpose: The aim of this study was to evaluate the effect of polyethylene fiber inserts on gingival microleakage of class II composite restorations using two different adhesive systems. Materials and Method: In this experimental study, class II cavities were prepared on 60 premolars. The gingival floor was located 1.0 mm below the CEJ. Dimension of each cavity were 3 mm buccolingually and 1.5 mm in axial depth. The specimens were divided into 4 groups according to the adhesive type and fiber insert (n=4). Single bond and Clearfill SE bond and Filtek p60 were used to restore the cavities. In groups without fiber inserts composite was adapted onto cavities using layering technique. For cavities with fiber inserts, 3 mm piece of fiber insert was placed onto the composite increment and cured. The specimens were stored in distilled water at 37oC for 6 months. All specimens were subjected to 3000 thermo-cycling. The tooth surfaces except for 1 mm around the restoration margins covered with two layers of nail varnish .The teeth were immersed in 2% Basic Fuchsin for 24 hours, then rinsed and sectioned mesiodistally. The microleakage was determined under a stereomicroscope (40X). Data were statistically analyzed by Kruskal-wallis and Mann-Whitney U tests (p< 0.05). Results: The Kruskal-Wallis test revealed no significant differences in mean microleakage scores among all groups (p= 0.281). Conclusion: Use of polyethylene fiber inserts and etch-and-rinse and self-etch adhesives had no effect on microleakage in class II resin composite restorations with gingival margins below the CEJ after 6- month water storage. PMID:24724129
Fu, Liezhen; Wen, Luan; Luu, Nga; Shi, Yun-Bo
2016-01-01
Genome editing with designer nucleases such as TALEN and CRISPR/Cas enzymes has broad applications. Delivery of these designer nucleases into organisms induces various genetic mutations including deletions, insertions and nucleotide substitutions. Characterizing those mutations is critical for evaluating the efficacy and specificity of targeted genome editing. While a number of methods have been developed to identify the mutations, none other than sequencing allows the identification of the most desired mutations, i.e., out-of-frame insertions/deletions that disrupt genes. Here we report a simple and efficient method to visualize and quantify the efficiency of genomic mutations induced by genome-editing. Our approach is based on the expression of a two-color fusion protein in a vector that allows the insertion of the edited region in the genome in between the two color moieties. We show that our approach not only easily identifies developing animals with desired mutations but also efficiently quantifies the mutation rate in vivo. Furthermore, by using LacZα and GFP as the color moieties, our approach can even eliminate the need for a fluorescent microscope, allowing the analysis with simple bright field visualization. Such an approach will greatly simplify the screen for effective genome-editing enzymes and identify the desired mutant cells/animals. PMID:27748423
SvABA: genome-wide detection of structural variants and indels by local assembly.
Wala, Jeremiah A; Bandopadhayay, Pratiti; Greenwald, Noah F; O'Rourke, Ryan; Sharpe, Ted; Stewart, Chip; Schumacher, Steve; Li, Yilong; Weischenfeldt, Joachim; Yao, Xiaotong; Nusbaum, Chad; Campbell, Peter; Getz, Gad; Meyerson, Matthew; Zhang, Cheng-Zhong; Imielinski, Marcin; Beroukhim, Rameen
2018-04-01
Structural variants (SVs), including small insertion and deletion variants (indels), are challenging to detect through standard alignment-based variant calling methods. Sequence assembly offers a powerful approach to identifying SVs, but is difficult to apply at scale genome-wide for SV detection due to its computational complexity and the difficulty of extracting SVs from assembly contigs. We describe SvABA, an efficient and accurate method for detecting SVs from short-read sequencing data using genome-wide local assembly with low memory and computing requirements. We evaluated SvABA's performance on the NA12878 human genome and in simulated and real cancer genomes. SvABA demonstrates superior sensitivity and specificity across a large spectrum of SVs and substantially improves detection performance for variants in the 20-300 bp range, compared with existing methods. SvABA also identifies complex somatic rearrangements with chains of short (<1000 bp) templated-sequence insertions copied from distant genomic regions. We applied SvABA to 344 cancer genomes from 11 cancer types and found that short templated-sequence insertions occur in ∼4% of all somatic rearrangements. Finally, we demonstrate that SvABA can identify sites of viral integration and cancer driver alterations containing medium-sized (50-300 bp) SVs. © 2018 Wala et al.; Published by Cold Spring Harbor Laboratory Press.
Garcia, Anthony R.; Johnston, Roger G.
2003-07-08
The present invention provides an apparatus and method whereby the reliability and tamper-resistance of tamper indicators can be improved. A flexible connector may be routed through a latch for an enclosure such as a door or container, and the free ends of the flexible connector may be passed through a first locking member and firmly attached to an insert through the use of one or more attachment members such as set screws. A second locking member may then be assembled in interlocking relation with the first locking member to form an interlocked assembly around the insert. The insert may have one or more sharp projections extending toward the first or second locking member so that any compressive force applied in an attempt to disassemble the interlocked assembly results in permanent, visible damage to the first or second locking member.
Vasilikostas, Georgios; Sanmugalingam, Nimalan; Khan, Omar; Reddy, Marcus; Groves, Chris; Wan, Andrew
2014-03-01
Endoscopic stenting is a relatively new technique for the treatment of post sleeve gastrectomy complications. Partially covered stents are used in this method to minimise the risk of migration but they are associated with difficulties with removal. Patients requiring emergency stenting following sleeve gastrectomy underwent insertion of a partially covered metallic stent. One month later, if the stent was not easily removable, a fully covered overlapping stent was inserted and the patient was readmitted 2 weeks later for removal of both stents. Four patients required stenting following sleeve gastrectomy leaks, and one patient required stenting for a stricture. In these cases, a 'stent in a stent' technique was used for removal. This technique allows the safe removal of partially covered stents inserted following sleeve gastrectomy complications.
Computer Modeling of Protocellular Functions: Peptide Insertion in Membranes
NASA Technical Reports Server (NTRS)
Rodriquez-Gomez, D.; Darve, E.; Pohorille, A.
2006-01-01
Lipid vesicles became the precursors to protocells by acquiring the capabilities needed to survive and reproduce. These include transport of ions, nutrients and waste products across cell walls and capture of energy and its conversion into a chemically usable form. In modem organisms these functions are carried out by membrane-bound proteins (about 30% of the genome codes for this kind of proteins). A number of properties of alpha-helical peptides suggest that their associations are excellent candidates for protobiological precursors of proteins. In particular, some simple a-helical peptides can aggregate spontaneously and form functional channels. This process can be described conceptually by a three-step thermodynamic cycle: 1 - folding of helices at the water-membrane interface, 2 - helix insertion into the lipid bilayer and 3 - specific interactions of these helices that result in functional tertiary structures. Although a crucial step, helix insertion has not been adequately studied because of the insolubility and aggregation of hydrophobic peptides. In this work, we use computer simulation methods (Molecular Dynamics) to characterize the energetics of helix insertion and we discuss its importance in an evolutionary context. Specifically, helices could self-assemble only if their interactions were sufficiently strong to compensate the unfavorable Free Energy of insertion of individual helices into membranes, providing a selection mechanism for protobiological evolution.
Çeçen, Kürşat; Ülker, Kahraman
2014-01-01
Objective. Management options of gestational hydronephrosis are based on the coexisting stone disease, pyelonephritis, and renal disease. However, the management option and its consequences in the absence of a coexisting disease state are not clear. In this study we aimed to compare the effectiveness of conservative treatment and double J insertion in symptomatic pure gestational hydronephrosis. Material and Methods. The data of the women with severe pure gestational hydronephrosis over a nine-year period was collected retrospectively. The included women were grouped into two according to receiving double J stent insertion or conservative treatments. Results. Double J insertion and conservative treatment groups included 24 and 29 women, respectively. Hydronephrosis was demonstrated on the right, left, or both kidneys in 37 (70%), 13 (24%), and 3 (6%) women, respectively. None of the participants gave birth prior to the 37th week. The demographics, initial pain scores, the severity of the hydronephrosis during first admission, and pain scores one week after the interventions did not differ significantly between groups (P > 0.05). Similarly, the rates of complications, postpartum pain scores, and permanent hydronephrosis did not differ between groups (P > 0.05). Conclusion. Double J insertion in symptomatic pure gestational hydronephrosis adds no benefit to conservative treatment. PMID:24574939
Postplacental or delayed levonorgestrel intrauterine device insertion and breastfeeding duration
Chen, Beatrice A.; Reeves, Matthew F.; Creinin, Mitchell D.; Schwarz, E. Bimla
2011-01-01
BACKGROUND The objective was to assess the effect of timing of postpartum levonorgestrel-releasing IUD insertion on breastfeeding continuation. STUDY DESIGN Women interested in using a levonorgestrel IUD postpartum were randomized to immediate postplacental insertion (postplacental group) or insertion 6–8 weeks after vaginal delivery (delayed group). Duration and exclusivity of breastfeeding were assessed at 6–8 weeks, 3 months, and 6 months postpartum. Only women who received an IUD were included in this analysis. RESULTS Breastfeeding was initiated by 32/50 (64%) of women receiving a postplacental IUD and 27/46 (58.7%) of women receiving a delayed IUD (p=0.59). More women in the delayed group compared to the postplacental group continued to breastfeed at 6–8 weeks (16/46 vs 15/50, p=0.62), 3 months (13/46 vs 7/50, p=0.13), and 6 months postpartum (11/46 vs 3/50, p=0.02). The results did not differ when only women who initiated breastfeeding or only primiparous women with no prior breastfeeding experience were analyzed. CONCLUSIONS Immediate postplacental insertion of the levonorgestrel IUD is associated with shorter duration of breastfeeding and less exclusive breastfeeding. Further studies are needed of the effects of early initiation of progestin-only methods on women’s lactation experience. PMID:22018124
Spectral analysis of hearing protector impulsive insertion loss.
Fackler, Cameron J; Berger, Elliott H; Murphy, William J; Stergar, Michael E
2017-01-01
To characterise the performance of hearing protection devices (HPDs) in impulsive-noise conditions and to compare various protection metrics between impulsive and steady-state noise sources with different characteristics. HPDs were measured per the impulsive test methods of ANSI/ASA S12.42- 2010 . Protectors were measured with impulses generated by both an acoustic shock tube and an AR-15 rifle. The measured data were analysed for impulse peak insertion loss (IPIL) and impulsive spectral insertion loss (ISIL). These impulsive measurements were compared to insertion loss measured with steady-state noise and with real-ear attenuation at threshold (REAT). Tested HPDs included a foam earplug, a level-dependent earplug and an electronic sound-restoration earmuff. IPIL for a given protector varied between measurements with the two impulse noise sources, but ISIL agreed between the two sources. The level-dependent earplug demonstrated level-dependent effects both in IPIL and ISIL. Steady-state insertion loss and REAT measurements tended to provide a conservative estimate of the impulsively-measured attenuation. Measurements of IPIL depend strongly on the source used to measure them, especially for HPDs with less attenuation at low frequencies. ISIL provides an alternative measurement of impulse protection and appears to be a more complete description of an HPD's performance.
Spectral analysis of hearing protector impulsive insertion loss
Fackler, Cameron J.; Berger, Elliott H.; Murphy, William J.; Stergar, Michael E.
2017-01-01
Objective To characterize the performance of hearing protection devices in impulsive-noise conditions and to compare various protection metrics between impulsive and steady-state noise sources with different characteristics. Design Hearing protectors were measured per the impulsive test methods of ANSI/ASA S12.42-2010. Protectors were measured with impulses generated by both an acoustic shock tube and an AR-15 rifle. The measured data were analyzed for impulse peak insertion loss (IPIL) and impulsive spectral insertion loss (ISIL). These impulsive measurements were compared to insertion loss measured with steady-state noise and with real-ear attenuation at threshold (REAT). Study Sample Tested devices included a foam earplug, a level-dependent earplug, and an electronic sound-restoration earmuff. Results IPIL for a given protector varied between measurements with the two impulse noise sources, but ISIL agreed between the two sources. The level-dependent earplug demonstrated level-dependent effects both in IPIL and ISIL. Steady-state insertion loss and REAT measurements tended to provide a conservative estimate of the impulsively-measured attenuation. Conclusions Measurements of IPIL depend strongly on the source used to measure them, especially for hearing protectors with less attenuation at low frequencies. ISIL provides an alternative measurement of impulse protection and appears to be a more complete description of an HPD’s performance. PMID:27885881
Blood, men and tears: keeping IUDs in place in Bangladesh.
Bradley, Janet E; Alam, Mahboob-E-; Shabnam, Fatema; Beattie, Tara S H
2009-06-01
The Intra-Uterine Device (IUD) is an effective method of contraception, but in Bangladesh is associated with high levels of discontinuation within the first year. This study involved data collection from a retrospective cohort of women who had an IUD inserted 12 months earlier. In the cohort, 330 women were interviewed to identify factors associated with discontinuation. Later, 20 women, of the 103 who reported discontinuing because of excessive menstrual bleeding, were interviewed again and in depth about these issues. Of 330 women who had an IUD inserted, 47.3% had discontinued use one year post-insertion. In univariate and multivariate analyses, IUD discontinuation was strongly associated with side-effects (heavier periods; abdominal pain) and spousal factors (not discussing IUD with husband pre-insertion), but not with service delivery factors. In-depth interviews with women who reported excessive blood loss as the main reason for discontinuation found a doubling of both menstrual days and blood loss after IUD insertion. In Bangladesh, women cannot pray, have sexual intercourse, perform household tasks or participate in community activities during menstruation. Thus, women with menstrual side-effects faced serious physical, social and psychological challenges that made continuation difficult. Among those who discontinued, spouses were generally unsupportive and sometimes abusive, particularly when not involved in the decision to use the IUD.
NASA Astrophysics Data System (ADS)
Adams, Jacob; Unterberg, Ezekial; Chrobak, Christopher; Stahl, Brian; Abrams, Tyler
2017-10-01
Continuing analysis of tungsten-coated inserts from the recent DIII-D Metal Rings Campaign utilizes a statistical approach to study carbon migration and deposition on W surfaces and to characterize the pre- versus post-exposure surface morphology. A TZM base was coated with W using both CVD and PVD and allowed for comparison between the two coating methods. The W inserts were positioned in the lower DIII-D divertor in both the upper (shelf) region and lower (floor) region and subjected to multiple plasma shots, primarily in H-mode. Currently, the post-exposure W inserts are being characterized using SEM/EDX to qualify the surface morphology and to quantify the surface chemical composition. In addition, profilometry is being used to measure the surface roughness of the inserts both before and after plasma exposure. Preliminary results suggest a correlation between the pre-exposure surface roughness and the level of carbon deposited on the surface. Furthermore, ongoing in-depth analysis may reveal insights into the formation mechanism of nanoscale bumps found in the carbon-rich regions of the W surfaces that have not yet been explained. Work supported in part by US DoE under the Science Undergraduate Laboratory Internship (SULI) program and under DE-FC02-04ER54698.
Placement of percutaneous transhepatic biliary stent using a silicone drain with channels
Yoshida, Hiroshi; Mamada, Yasuhiro; Taniai, Nobuhiko; Mineta, Sho; Mizuguchi, Yoshiaki; Kawano, Yoichi; Sasaki, Junpei; Nakamura, Yoshiharu; Aimoto, Takayuki; Tajiri, Takashi
2009-01-01
This report describes a method for percutaneous transhepatic biliary stenting with a BLAKE Silicone Drain, and discusses the usefulness of placement of the drain connected to a J-VAC Suction Reservoir for the treatment of stenotic hepaticojejunostomy. Percutaneous transhepatic biliary drainage was performed under ultrasonographic guidance in a patient with stenotic hepaticojejunostomy after hepatectomy for hepatic hilum malignancy. The technique used was as follows. After dilatation of the drainage root, an 11-Fr tube with several side holes was passed through the stenosis of the hepaticojejunostomy. A 10-Fr BLAKE Silicone Drain is flexible, which precludes one-step insertion. One week after insertion of the 11-Fr tube, a 0.035-inch guidewire was inserted into the tube. After removal of the 11-Fr tube, the guidewire was put into the channel of a 10-Fr BLAKE Silicone Drain. The drain was inserted into the jejunal limb through the intrahepatic bile duct and was connected to a J-VAC Suction Reservoir. Low-pressure continued suction was applied. Patients can be discharged after insertion of the 10-Fr BLAKE Silicone Drain connected to the J-VAC Suction Reservoir. Placement of a percutaneous transhepatic biliary stent using a 10-Fr BLAKE Silicone Drain connected to a J-VAC Suction Reservoir is useful for the treatment of stenotic hepaticojejunostomy. PMID:19725159
2012-01-01
Introduction Catheter-related bloodstream infections (CRBSIs) associated with short-term central venous catheters (CVCs) in intensive care unit (ICU) patients are a major clinical problem. Bacterial colonization of the skin at the CVC insertion site is an important etiologic factor for CRBSI. The aim of this study was to assess the efficacy of medical-grade honey in reducing bacterial skin colonization at insertion sites. Methods A prospective, single-center, open-label randomized controlled trial was performed at the ICU of a university hospital in The Netherlands to assess the efficacy of medical-grade honey to reduce skin colonization of insertion sites. Medical-grade honey was applied in addition to standard CVC-site dressing and disinfection with 0.5% chlorhexidine in 70% alcohol. Skin colonization was assessed on a daily basis before CVC-site disinfection. The primary end point was colonization of insertion sites with >100 colony-forming units at the last sampling before removal of the CVC or transfer of the patient from the ICU. Secondary end points were quantitative levels of colonization of the insertion sites and colonization of insertion sites stratified for CVC location. Results Colonization of insertion sites was not affected by the use of medical-grade honey, as 44 (34%) of 129 and 36 (34%) of 106 patients in the honey and standard care groups, respectively, had a positive skin culture (P = 0.98). Median levels of skin colonization at the last sampling were 1 (0 to 2.84) and 1 (0 to 2.70) log colony-forming units (CFUs)/swab for the honey and control groups, respectively (P = 0.94). Gender, days of CVC placement, CVC location, and CVC type were predictive for a positive skin culture. Correction for these variables did not change the effect of honey on skin-culture positivity. Conclusions Medical-grade honey does not affect colonization of the skin at CVC insertion sites in ICU patients when applied in addition to standard disinfection with 0.5% chlorhexidine in 70% alcohol. Trial registration Netherlands Trial Registry, NTR1652. PMID:23111148
A method for the imbibition and germination of wheat seeds in space
NASA Technical Reports Server (NTRS)
Levine, H. G.; Piastuch, W. C.; Sager, J. C. (Principal Investigator)
1999-01-01
A method was developed for the reliable germination in space of wheat seeds on porous tube nutrient delivery systems. Germination paper strips were loosely rolled into cylinders and two seeds inserted close to the outer edges of each cylinder. This configuration: 1) directed the emerging shoots upward and roots downward, 2) was efficient in wicking moisture from the porous tubes, and 3) provided open areas for oxygen diffusion. Cotton tufts were inserted into the bottom crevices of the cylinders to fix the seeds in a mid-level position and cylinders were then storable (indefinitely) prior to the preprogrammed (on-orbit) initiation of imbibition. This method extends both the upper and lower ends of acceptable moisture levels for successful seed germination, increasing the probability of success for spaceflight applications where moisture availability is more variable than on Earth.
Identification of genomic indels and structural variations using split reads
2011-01-01
Background Recent studies have demonstrated the genetic significance of insertions, deletions, and other more complex structural variants (SVs) in the human population. With the development of the next-generation sequencing technologies, high-throughput surveys of SVs on the whole-genome level have become possible. Here we present split-read identification, calibrated (SRiC), a sequence-based method for SV detection. Results We start by mapping each read to the reference genome in standard fashion using gapped alignment. Then to identify SVs, we score each of the many initial mappings with an assessment strategy designed to take into account both sequencing and alignment errors (e.g. scoring more highly events gapped in the center of a read). All current SV calling methods have multilevel biases in their identifications due to both experimental and computational limitations (e.g. calling more deletions than insertions). A key aspect of our approach is that we calibrate all our calls against synthetic data sets generated from simulations of high-throughput sequencing (with realistic error models). This allows us to calculate sensitivity and the positive predictive value under different parameter-value scenarios and for different classes of events (e.g. long deletions vs. short insertions). We run our calculations on representative data from the 1000 Genomes Project. Coupling the observed numbers of events on chromosome 1 with the calibrations gleaned from the simulations (for different length events) allows us to construct a relatively unbiased estimate for the total number of SVs in the human genome across a wide range of length scales. We estimate in particular that an individual genome contains ~670,000 indels/SVs. Conclusions Compared with the existing read-depth and read-pair approaches for SV identification, our method can pinpoint the exact breakpoints of SV events, reveal the actual sequence content of insertions, and cover the whole size spectrum for deletions. Moreover, with the advent of the third-generation sequencing technologies that produce longer reads, we expect our method to be even more useful. PMID:21787423
Mechanisms for sodium insertion in carbon materials
NASA Astrophysics Data System (ADS)
Stevens, David Andrew
2000-12-01
This thesis details the mechanisms for sodium insertion into different carbons using both electrochemical and vapour techniques. Room temperature electrochemical measurements were completed to examine the insertion and removal of sodium from soft (graphitizable) and nanoporous hard (non-graphitizable) carbons prepared by the heat treatment of organic precursors to a range of temperatures. The mechanisms identified from these studies were further investigated through a series of in situ x-ray scattering studies on operating electrochemical cells. The results obtained were then compared with x-ray scattering measurements on carbons after exposure to sodium vapour at 890C. This work is primarily driven by the aluminium industry's need to understand how sodium insertion causes carbon cathode blocks in aluminium reduction cells to swell. The results obtained are also of relevance to the lithium-ion battery field as they help to verify mechanisms proposed in the literature for lithium insertion into carbon hosts. Some carbons were also identified that could accommodate large amounts of sodium, making them attractive candidates for anodes in rechargeable sodium ion batteries. For soft carbons, the results showed that both sodium and lithium insert between approximately parallel carbon layers along the sloping voltage region of the electrochemical curves, increasing the average interlayer spacing. The sodium and lithium capacities decreased with increasing carbon heat treatment temperature. For the soft carbons studied, the sodium capacity was found to be consistently lower than the lithium capacity, implying that some lithium-accessible sites were unavailable for sodium insertion. The electrochemical profiles for the hard carbons also contained capacity along a sloping voltage region and, as with the soft carbons, this was shown to result from the insertion of sodium and lithium between approximately parallel carbon layers. In contrast to the soft carbons, however, the electrochemical profiles for the hard carbons also exhibited significant capacity along low voltage plateaus at chemical potentials close to the chemical potential of the metal. An in situ small angle x-ray scattering experimental method was therefore developed to examine changes in scattering from the nanopores during sodium and lithium insertion/removal. The results from this technique clearly showed that the low voltage plateau capacity resulted from the insertion of sodium and lithium into nanopores in the carbon.
COLLECTING URINE SAMPLES FROM YOUNG CHILDREN FOR PESTICIDE STUDIES
To estimate pesticide exposure for young children wearing diapers, a method for collecting urine samples for analysis of pesticide metabolites is needed. To find a practical method, two possibilities were investigated: (1) analysis of expressed urine from cotton diaper inserts ...
Method of inactivation of an end product of energy metabolism in Zymomonas mobilis
Zhang, Min [Lakewood, CO; Chou, Yat-Chen [Lakewood, CO
2008-05-20
The present invention briefly provides a method of site-specific insertion in Zymomonas, comprising, providing a Zymomonas gene fragment, interrupting a DNA sequence the fragment, and transforming the Zymomonas through homologous recombination with the interrupted fragment.
Methods for elimination of dampness in Building walls
NASA Astrophysics Data System (ADS)
Campian, Cristina; Pop, Maria
2016-06-01
Dampness elimination in building walls is a very sensitive problem, with high costs. Many methods are used, as: chemical method, electro osmotic method or physical method. The RECON method is a representative and a sustainable method in Romania. Italy has the most radical method from all methods. The technology consists in cutting the brick walls, insertion of a special plastic sheeting and injection of a pre-mixed anti-shrinking mortar.
Sabri, Suriana; Steen, Jennifer A; Bongers, Mareike; Nielsen, Lars K; Vickers, Claudia E
2013-06-24
Metabolic engineering projects often require integration of multiple genes in order to control the desired phenotype. However, this often requires iterative rounds of engineering because many current insertion approaches are limited by the size of the DNA that can be transferred onto the chromosome. Consequently, construction of highly engineered strains is very time-consuming. A lack of well-characterised insertion loci is also problematic. A series of knock-in/knock-out (KIKO) vectors was constructed for integration of large DNA sequences onto the E. coli chromosome at well-defined loci. The KIKO plasmids target three nonessential genes/operons as insertion sites: arsB (an arsenite transporter); lacZ (β-galactosidase); and rbsA-rbsR (a ribose metabolism operon). Two homologous 'arms' target each insertion locus; insertion is mediated by λ Red recombinase through these arms. Between the arms is a multiple cloning site for the introduction of exogenous sequences and an antibiotic resistance marker (either chloramphenicol or kanamycin) for selection of positive recombinants. The resistance marker can subsequently be removed by flippase-mediated recombination. The insertion cassette is flanked by hairpin loops to isolate it from the effects of external transcription at the integration locus. To characterize each target locus, a xylanase reporter gene (xynA) was integrated onto the chromosomes of E. coli strains W and K-12 using the KIKO vectors. Expression levels varied between loci, with the arsB locus consistently showing the highest level of expression. To demonstrate the simultaneous use of all three loci in one strain, xynA, green fluorescent protein (gfp) and a sucrose catabolic operon (cscAKB) were introduced into lacZ, arsB and rbsAR respectively, and shown to be functional. The KIKO plasmids are a useful tool for efficient integration of large DNA fragments (including multiple genes and pathways) into E. coli. Chromosomal insertion provides stable expression without the need for continuous antibiotic selection. Three non-essential loci have been characterised as insertion loci; combinatorial insertion at all three loci can be performed in one strain. The largest insertion at a single site described here was 5.4 kb; we have used this method in other studies to insert a total of 7.3 kb at one locus and 11.3 kb across two loci. These vectors are particularly useful for integration of multigene cassettes for metabolic engineering applications.
Sod, Gary A; Riggs, Laura M; Mitchell, Colin F; Hubert, Jeremy D; Martin, George S
2010-01-01
To compare in vitro monotonic biomechanical properties of an axial 3-hole, 4.5 mm narrow dynamic compression plate (DCP) using 5.5 mm cortical screws in conjunction with 2 abaxial transarticular 5.5 mm cortical screws inserted in lag fashion (DCP-TLS) with 3 parallel transarticular 5.5 mm cortical screws inserted in lag fashion (3-TLS) for the equine proximal interphalangeal (PIP) joint arthrodesis. Paired in vitro biomechanical testing of 2 methods of stabilizing cadaveric adult equine forelimb PIP joints. Cadaveric adult equine forelimbs (n=15 pairs). For each forelimb pair, 1 PIP joint was stabilized with an axial 3-hole narrow DCP (4.5 mm) using 5.5 mm cortical screws in conjunction with 2 abaxial transarticular 5.5 mm cortical screws inserted in lag fashion and 1 with 3 parallel transarticular 5.5 mm cortical screws inserted in lag fashion. Five matching pairs of constructs were tested in single cycle to failure under axial compression, 5 construct pairs were tested for cyclic fatigue under axial compression, and 5 construct pairs were tested in single cycle to failure under torsional loading. Mean values for each fixation method were compared using a paired t-test within each group with statistical significance set at P<.05. Mean yield load, yield stiffness, and failure load under axial compression and torsion, single cycle to failure, of the DCP-TLS fixation were significantly greater than those of the 3-TLS fixation. Mean cycles to failure in axial compression of the DCP-TLS fixation was significantly greater than that of the 3-TLS fixation. The DCP-TLS was superior to the 3-TLS in resisting the static overload forces and in resisting cyclic fatigue. The results of this in vitro study may provide information to aid in the selection of a treatment modality for arthrodesis of the equine PIP joint.
Efficient gene editing in Corynebacterium glutamicum using the CRISPR/Cas9 system.
Peng, Feng; Wang, Xinyue; Sun, Yang; Dong, Guibin; Yang, Yankun; Liu, Xiuxia; Bai, Zhonghu
2017-11-14
Corynebacterium glutamicum (C. glutamicum) has traditionally been used as a microbial cell factory for the industrial production of many amino acids and other industrially important commodities. C. glutamicum has recently been established as a host for recombinant protein expression; however, some intrinsic disadvantages could be improved by genetic modification. Gene editing techniques, such as deletion, insertion, or replacement, are important tools for modifying chromosomes. In this research, we report a CRISPR/Cas9 system in C. glutamicum for rapid and efficient genome editing, including gene deletion and insertion. The system consists of two plasmids: one containing a target-specific guide RNA and a homologous sequence to a target gene, the other expressing Cas9 protein. With high efficiency (up to 100%), this system was used to disrupt the porB, mepA, clpX and Ncgl0911 genes, which affect the ability to express proteins. The porB- and mepA-deletion strains had enhanced expression of green fluorescent protein, compared with the wild-type stain. This system can also be used to engineer point mutations and gene insertions. In this study, we adapted the CRISPR/Cas9 system from S. pyogens to gene deletion, point mutations and insertion in C. glutamicum. Compared with published genome modification methods, methods based on the CRISPR/Cas9 system can rapidly and efficiently achieve genome editing. Our research provides a powerful tool for facilitating the study of gene function, metabolic pathways, and enhanced productivity in C. glutamicum.
Goossens, Quentin; Leuridan, Steven; Henyš, Petr; Roosen, Jorg; Pastrav, Leonard; Mulier, Michiel; Desmet, Wim; Denis, Kathleen; Vander Sloten, Jos
2017-11-01
In cementless total hip arthroplasty (THA), the initial stability is obtained by press-fitting the implant in the bone to allow osseointegration for a long term secondary stability. However, finding the insertion endpoint that corresponds to a proper initial stability is currently based on the tactile and auditory experiences of the orthopedic surgeon, which can be challenging. This study presents a novel real-time method based on acoustic signals to monitor the acetabular implant fixation in cementless total hip arthroplasty. Twelve acoustic in vitro experiments were performed on three types of bone models; a simple bone block model, an artificial pelvic model and a cadaveric model. A custom made beam was screwed onto the implant which functioned as a sound enhancer and insertor. At each insertion step an acoustic measurement was performed. A significant acoustic resonance frequency shift was observed during the insertion process for the different bone models; 250 Hz (35%, second bending mode) to 180 Hz (13%, fourth bending mode) for the artificial bone block models and 120 Hz (11%, eighth bending mode) for the artificial pelvis model. No significant frequency shift was observed during the cadaveric experiment due to a lack of implant fixation in this model. This novel diagnostic method shows the potential of using acoustic signals to monitor the implant seating during insertion. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.
Rapid discrimination of sequences flanking and within T-DNA insertions in the Arabidopsis genome.
Ponce, M R; Quesada, V; Micol, J L
1998-05-01
An improvement to previous methods for recovering Arabidopsis thaliana genomic DNA flanking T-DNA insertions is presented that allows for the avoidance of some of the cloning difficulties caused by the concatameric nature of T-DNA inserts. The principle of the procedure is to categorize by size restriction fragments of mutant DNA, produced in separate digestions with NdeI and Bst1107I. Given that the sites for these two enzymes are contiguous within the pGV3850:1003 T-DNA construct, the restriction fragments obtained fall into two categories: those showing identical size in both digestions, which correspond to sequences internal to T-DNA concatamers; and those of different sizes, that contain the junctions between plant DNA and the T-DNA insert. Such a criterion makes it possible to easily distinguish the digestion products corresponding to internal T-DNA parts, which do not deserve further attention, and those which presumably include a segment of the locus of interest. Discrimination between restriction fragments of genomic mutant DNA can be made on rescued plasmids, inverse PCR amplification products or bands in a genomic blot.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Eu Hyun, E-mail: doorihyun6@gmail.com; Oh, Jung Suk; Chun, Ho Jong
PurposeThe study aimed to introduce a monorail technique to overcome difficult anatomical course via left internal jugular vein in implantable port insertion.MethodsFrom 2007 to 2016, a total of 9346 patients were referred for implantable port insertion in our interventional unit, among which 79 cases were requested to insert on the left side. Our monorail technique was applied only when the technical challenge of the catheter tip entering the azygos vein instead of the superior vena cava occurred (n = 7). The technique consists of puncturing at the distal tip of the port catheter with a 21-gauge micropuncture needle and advancing a 0.018-in.more » hair-wire to guide and provide support for pre-assembled port.ResultsThe monorail technique was performed in seven patients and all but one case were technically successful, showing a technical success rate of 85.7%. There were no immediate or delayed complications.ConclusionsThe monorail technique is helpful to overcome the difficult anatomical course via left internal jugular vein in implantable port insertion.« less
Investigation of AWG demultiplexer based SOI for CWDM application
NASA Astrophysics Data System (ADS)
Juhari, Nurjuliana; Susthitha Menon, P.; Shaari, Sahbudin; Annuar Ehsan, Abang
2017-11-01
9-channel Arrayed Waveguide Grating (AWG) demultiplexer for conventional and tapered structure were simulated using beam propagation method (BPM) with channel spacing of 20 nm. The AWG demultiplexer was design using high refractive index (n 3.47) material namely silicon-on-insulator (SOI) with rib waveguide structure. The characteristics of insertion loss, adjacent crosstalk and output spectrum response at central wavelength of 1.55 μm for both designs were compared and analyzed. The conventional AWG produced a minimum insertion loss of 6.64 dB whereas the tapered AWG design reduced the insertion loss by 2.66 dB. The lowest adjacent crosstalk value of -16.96 dB was obtained in the conventional AWG design and this was much smaller compared to the tapered AWG design where the lowest crosstalk value is -17.23 dB. Hence, a tapered AWG design significantly reduces the insertion loss but has a slightly higher adjacent crosstalk compared to the conventional AWG design. On the other hand, the output spectrum responses that are obtained from both designs were close to the Coarse Wavelength Division Multiplexing (CWDM) wavelength grid.