IDG - INTERACTIVE DIF GENERATOR
NASA Technical Reports Server (NTRS)
Preheim, L. E.
1994-01-01
The Interactive DIF Generator (IDG) utility is a tool used to generate and manipulate Directory Interchange Format files (DIF). Its purpose as a specialized text editor is to create and update DIF files which can be sent to NASA's Master Directory, also referred to as the International Global Change Directory at Goddard. Many government and university data systems use the Master Directory to advertise the availability of research data. The IDG interface consists of a set of four windows: (1) the IDG main window; (2) a text editing window; (3) a text formatting and validation window; and (4) a file viewing window. The IDG main window starts up the other windows and contains a list of valid keywords. The keywords are loaded from a user-designated file and selected keywords can be copied into any active editing window. Once activated, the editing window designates the file to be edited. Upon switching from the editing window to the formatting and validation window, the user has options for making simple changes to one or more files such as inserting tabs, aligning fields, and indenting groups. The viewing window is a scrollable read-only window that allows fast viewing of any text file. IDG is an interactive tool and requires a mouse or a trackball to operate. IDG uses the X Window System to build and manage its interactive forms, and also uses the Motif widget set and runs under Sun UNIX. IDG is written in C-language for Sun computers running SunOS. This package requires the X Window System, Version 11 Revision 4, with OSF/Motif 1.1. IDG requires 1.8Mb of hard disk space. The standard distribution medium for IDG is a .25 inch streaming magnetic tape cartridge in UNIX tar format. It is also available on a 3.5 inch diskette in UNIX tar format. The program was developed in 1991 and is a copyrighted work with all copyright vested in NASA. SunOS is a trademark of Sun Microsystems, Inc. X Window System is a trademark of Massachusetts Institute of Technology. OSF/Motif is a trademark of the Open Software Foundation, Inc. UNIX is a trademark of Bell Laboratories.
WinSCP for Windows File Transfers | High-Performance Computing | NREL
WinSCP for Windows File Transfers WinSCP for Windows File Transfers WinSCP for can used to securely transfer files between your local computer running Microsoft Windows and a remote computer running Linux
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-03
... Fund Phase I Auction (Auction 902); Short-Form Application Filing Window Rescheduled To Open on... rescheduling of the filing window for short-form applications and release an updated list of eligible areas for... Application Filing Window Rescheduled To Open on September 30, 2013 1. The Bureaus announce that the filing...
47 CFR 73.871 - Amendment of LPFM broadcast station applications.
Code of Federal Regulations, 2010 CFR
2010-10-01
... limitation during the pertinent filing window. (b) Amendments that would improve the comparative position of new and major change applications will not be accepted after the close of the pertinent filing window... the pertinent filing window. Subject to the provisions of this section, such amendments may be filed...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-31
... Qualifications Window (``TQ Window''). During the TQ Window, any Tribe or Tribal entity that could qualify to add... filed Form 301 application to be considered at this stage, then during the TQ Window the original Tribal... acceptable application is filed during the TQ Window, whether by the original Tribal allotment proponent...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-15
...) announce the rescheduling of Auction 902 and revise the dates and deadlines for the filing window for short...-auction deadlines for Auction 902. 2. The Auction 902 short-form application filing window opened at 12... short-form application (FCC Form 180) filing window will reopen on November 18, 2013, at 12:00 noon ET...
Object-oriented approach to fast display of electrophysiological data under MS-windows.
Marion-Poll, F
1995-12-01
Microcomputers provide neuroscientists an alternative to a host of laboratory equipment to record and analyze electrophysiological data. Object-oriented programming tools bring an essential link between custom needs for data acquisition and analysis with general software packages. In this paper, we outline the layout of basic objects that display and manipulate electrophysiological data files. Visual inspection of the recordings is a basic requirement of any data analysis software. We present an approach that allows flexible and fast display of large data sets. This approach involves constructing an intermediate representation of the data in order to lower the number of actual points displayed while preserving the aspect of the data. The second group of objects is related to the management of lists of data files. Typical experiments designed to test the biological activity of pharmacological products include scores of files. Data manipulation and analysis are facilitated by creating multi-document objects that include the names of all experiment files. Implementation steps of both objects are described for an MS-Windows hosted application.
The 60 Minute Network Security Guide (First Steps Towards a Secure Network Environment)
2001-10-16
default/ passwd file in UNIX. Administrators should obtain and run password-guessing programs (i.e., “John the Ripper,’’ “L0phtCrack,” and “Crack...system on which it is running, it is a good idea to transfer the encrypted passwords (the dumped SAM database for Windows and the /etc/ passwd and /etc...ownership by root and group sys. The /etc/ passwd file should have permissions 644 with owner root and group root. n Be cracked every month to find
Katzman, G L
2001-03-01
The goal of the project was to create a method by which an in-house digital teaching file could be constructed that was simple, inexpensive, independent of hypertext markup language (HTML) restrictions, and appears identical on multiple platforms. To accomplish this, Microsoft PowerPoint and Adobe Acrobat were used in succession to assemble digital teaching files in the Acrobat portable document file format. They were then verified to appear identically on computers running Windows, Macintosh Operating Systems (OS), and the Silicon Graphics Unix-based OS as either a free-standing file using Acrobat Reader software or from within a browser window using the Acrobat browser plug-in. This latter display method yields a file viewed through a browser window, yet remains independent of underlying HTML restrictions, which may confer an advantage over simple HTML teaching file construction. Thus, a hybrid of HTML-distributed Adobe Acrobat generated WWW documents may be a viable alternative for digital teaching file construction and distribution.
75 FR 27984 - Broadband Technology Opportunities Program
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-19
....: 0907141137-0222-10] RIN 0660-ZA28 Broadband Technology Opportunities Program AGENCY: National...; Reopening of Application Filing Window for Broadband Technology Opportunities Program Comprehensive... filing window for the Broadband Technology Opportunities Program (BTOP) that the agency established...
Interior, detail view of last original windows and filed in ...
Interior, detail view of last original windows and filed in wall arches, also concrete block wall of beryllum/uranium labs to left, looking southwest near center of west elevation, main building. - Watertown Arsenal, Building No. 312, Wooley Avenue, Watertown, Middlesex County, MA
Navigating the Internet: Evaluating Gopher Clients for Windows.
ERIC Educational Resources Information Center
Lonardo, Angela; And Others
1995-01-01
Identifies and discusses the criteria that end users might employ when evaluating a gopher client, particularly for the Windows environment. Topics include cost and availability, help features, functionality, viewing, searching, navigating, bookmarks, retrieving and displaying files, robustness, and gopher clients available via FTP (file transfer…
1988-05-12
the "load IC" menu option. A prompt will appear in the typescript window requesting the name of the knowledge base to be loaded. Enter...highlighted and then a prompt will appear in the typescript window. The prompt will be requesting the name of the file containing the message to be read in...the file name, the system will begin reading in the message. The listified message is echoed back in the typescript window. After that, the screen
Rootkit Detection Using a Cross-View Clean Boot Method
2013-03-01
FindNextFile: [2] Kernel32.dll 4. SSDTHooks r -- ... CALL NtQueryDirectoryFile 5. Code Patch ing - 6. Layered Driver 4 NtQueryDirectoryFile : 7...NTFS Driver 0 Volume Manger Disk Driver [2] I. Disk Driver r ! J IAT hooks take advantage of function calls in applications [13]. When an...f36e923898161fa7be50810288e2f48a 61 Appendix D: Windows Source Code Windows Batch File @echo o f f py thon walk . py pause shutdown − r − t 0 Walk.py in
Calibration of the Total and Static Pressure Transducers in the DSTO Transonic Wind Tunnel
2010-08-01
handled by the ActiveX control MSCOMM32.OCX which is not part of the Microsoft Windows operating system. It is, however, included as part of the...implemented new measures to register ActiveX controls in its Windows suite of operating systems, which has made the above file obsolete and it could no...longer be used if the Windows operating system were updated. If this is the case, then the new version of ActiveX control files can be installed using
PHREEQCI; a graphical user interface for the geochemical computer program PHREEQC
Charlton, Scott R.; Macklin, Clifford L.; Parkhurst, David L.
1997-01-01
PhreeqcI is a Windows-based graphical user interface for the geochemical computer program PHREEQC. PhreeqcI provides the capability to generate and edit input data files, run simulations, and view text files containing simulation results, all within the framework of a single interface. PHREEQC is a multipurpose geochemical program that can perform speciation, inverse, reaction-path, and 1D advective reaction-transport modeling. Interactive access to all of the capabilities of PHREEQC is available with PhreeqcI. The interface is written in Visual Basic and will run on personal computers under the Windows(3.1), Windows95, and WindowsNT operating systems.
SolTrace FAQs | Concentrating Solar Power | NREL
that should be noted: when using a cubic spline file to describe a surface, if that file contains a help for script functions? A: Yes, when typing a script function within the scripting window, as you results. When the limit is reached, SolTrace generates the following error message (Windows version; Mac
Kamauu, Aaron W C; DuVall, Scott L; Wiggins, Richard H; Avrin, David E
2008-09-01
In the creation of interesting radiological cases in a digital teaching file, it is necessary to adjust the window and level settings of an image to effectively display the educational focus. The web-based applet described in this paper presents an effective solution for real-time window and level adjustments without leaving the picture archiving and communications system workstation. Optimized images are created, as user-defined parameters are passed between the applet and a servlet on the Health Insurance Portability and Accountability Act-compliant teaching file server.
77 FR 1486 - Information Collections Being Reviewed by the Federal Communications Commission
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-10
... Commission will announce by Public Notice a Threshold Qualifications Window (``TQ Window''). During the TQ Window, any Tribe or Tribal entity that could qualify to add that particular Tribal Allotment may file an... considered at this stage, then during the TQ Window the original Tribal Allotment proponent must submit...
LACIE performance predictor final operational capability program description, volume 1
NASA Technical Reports Server (NTRS)
1976-01-01
The program EPHEMS computes the orbital parameters for up to two vehicles orbiting the earth for up to 549 days. The data represents a continuous swath about the earth, producing tables which can be used to determine when and if certain land segments will be covered. The program GRID processes NASA's climatology tape to obtain the weather indices along with associated latitudes and longitudes. The program LUMP takes substrata historical data and sample segment ID, crop window, crop window error and statistical data, checks for valid input parameters and generates the segment ID file, crop window file and the substrata historical file. Finally, the System Error Executive (SEE) Program checks YES error and truth data, CAMS error data, and signature extension data for validity and missing elements. A message is printed for each error found.
NASA Technical Reports Server (NTRS)
Santiago-Espada, Yamira; Myer, Robert R.; Latorella, Kara A.; Comstock, James R., Jr.
2011-01-01
The Multi-Attribute Task Battery (MAT Battery). is a computer-based task designed to evaluate operator performance and workload, has been redeveloped to operate in Windows XP Service Pack 3, Windows Vista and Windows 7 operating systems.MATB-II includes essentially the same tasks as the original MAT Battery, plus new configuration options including a graphical user interface for controlling modes of operation. MATB-II can be executed either in training or testing mode, as defined by the MATB-II configuration file. The configuration file also allows set up of the default timeouts for the tasks, the flow rates of the pumps and tank levels of the Resource Management (RESMAN) task. MATB-II comes with a default event file that an experimenter can modify and adapt
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-14
... Commission will announce by Public Notice a Threshold Qualifications Window (``TQ Window''). During the TQ Window, any Tribe or Tribal entity that could qualify to add that particular Tribal Allotment may file an... considered at this stage, then during the TQ Window the original Tribal Allotment proponent must submit...
Data Storage and Transfer | High-Performance Computing | NREL
High-Performance Computing (HPC) systems. Photo of computer server wiring and lights, blurred to show data. WinSCP for Windows File Transfers Use to transfer files from a local computer to a remote computer. Robinhood for File Management Use this tool to manage your data files on Peregrine. Best
VISUAL PLUMES CONCEPTS TO POTENTIALLY ADAPT OR ADOPT IN MODELING PLATFORMS SUCH AS VISJET
Windows-based programs share many familiar features and components. For example, file dialogue windows are familiar to most Windows-based personal computer users. Such program elements are desirable because the user is already familiar with how they function, obviating the need f...
47 CFR 73.870 - Processing of LPFM broadcast station applications.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Notice a window filing period for applications for new LPFM stations and major modifications in the... authorized LPFM stations will be accepted only during the appropriate window. Applications submitted prior to the window opening date identified in the Public Notice will be returned as premature. Applications...
Detecting Hardware-assisted Hypervisor Rootkits within Nested Virtualized Environments
2012-06-14
least the minimum required for the guest OS and click “Next”. For 64-bit Windows 7 the minimum required is 2048 MB (Figure 66). Figure 66. Memory...prompted for Memory, allocate at least the minimum required for the guest OS, for 64-bit Windows 7 the minimum required is 2048 MB (Figure 79...130 21. Within the virtual disk creation wizard, select VDI for the file type (Figure 81). Figure 81. Select File Type 22. Select Dynamically
Model Analyst’s Toolkit User Guide, Version 7.1.0
2015-08-01
Help > About) Environment details ( operating system ) metronome.log file, located in your MAT 7.1.0 installation folder Any log file that...requirements to run the Model Analyst’s Toolkit: Windows XP operating system (or higher) with Service Pack 2 and all critical Windows updates installed...application icon on your desktop Create a Quick Launch icon – Creates a MAT application icon on the taskbar for operating systems released
An Efficient Format for Nearly Constant-Time Access to Arbitrary Time Intervals in Large Trace Files
Chan, Anthony; Gropp, William; Lusk, Ewing
2008-01-01
A powerful method to aid in understanding the performance of parallel applications uses log or trace files containing time-stamped events and states (pairs of events). These trace files can be very large, often hundreds or even thousands of megabytes. Because of the cost of accessing and displaying such files, other methods are often used that reduce the size of the tracefiles at the cost of sacrificing detail or other information. This paper describes a hierarchical trace file format that provides for display of an arbitrary time window in a time independent of the total size of the file and roughlymore » proportional to the number of events within the time window. This format eliminates the need to sacrifice data to achieve a smaller trace file size (since storage is inexpensive, it is necessary only to make efficient use of bandwidth to that storage). The format can be used to organize a trace file or to create a separate file of annotations that may be used with conventional trace files. We present an analysis of the time to access all of the events relevant to an interval of time and we describe experiments demonstrating the performance of this file format.« less
lcps: Light curve pre-selection
NASA Astrophysics Data System (ADS)
Schlecker, Martin
2018-05-01
lcps searches for transit-like features (i.e., dips) in photometric data. Its main purpose is to restrict large sets of light curves to a number of files that show interesting behavior, such as drops in flux. While lcps is adaptable to any format of time series, its I/O module is designed specifically for photometry of the Kepler spacecraft. It extracts the pre-conditioned PDCSAP data from light curves files created by the standard Kepler pipeline. It can also handle csv-formatted ascii files. lcps uses a sliding window technique to compare a section of flux time series with its surroundings. A dip is detected if the flux within the window is lower than a threshold fraction of the surrounding fluxes.
Bulk Extractor 1.4 User’s Manual
2013-08-01
optimistically decompresses data in ZIP, GZIP, RAR, and Mi- crosoft’s Hibernation files. This has proven useful, for example, in recovering email...command line. Java 7 or above must be installed on the machine for the Bulk Extractor Viewer to run. Instructions on running bulk_extractor from the... Hibernation File Fragments (decompressed and processed, not carved) Subsection 4.6 winprefetch Windows Prefetch files, file fragments (processed
Volcanoes of the Wrangell Mountains and Cook Inlet region, Alaska: selected photographs
Neal, Christina A.; McGimsey, Robert G.; Diggles, Michael F.
2001-01-01
Alaska is home to more than 40 active volcanoes, many of which have erupted violently and repeatedly in the last 200 years. This CD-ROM contains 97 digitized color 35-mm images which represent a small fraction of thousands of photographs taken by Alaska Volcano Observatory scientists, other researchers, and private citizens. The photographs were selected to portray Alaska's volcanoes, to document recent eruptive activity, and to illustrate the range of volcanic phenomena observed in Alaska. These images are for use by the interested public, multimedia producers, desktop publishers, and the high-end printing industry. The digital images are stored in the 'images' folder and can be read across Macintosh, Windows, DOS, OS/2, SGI, and UNIX platforms with applications that can read JPG (JPEG - Joint Photographic Experts Group format) or PCD (Kodak's PhotoCD (YCC) format) files. Throughout this publication, the image numbers match among the file names, figure captions, thumbnail labels, and other references. Also included on this CD-ROM are Windows and Macintosh viewers and engines for keyword searches (Adobe Acrobat Reader with Search). At the time of this publication, Kodak's policy on the distribution of color-management files is still unresolved, and so none is included on this CD-ROM. However, using the Universal Ektachrome or Universal Kodachrome transforms found in your software will provide excellent color. In addition to PhotoCD (PCD) files, this CD-ROM contains large (14.2'x19.5') and small (4'x6') screen-resolution (72 dots per inch; dpi) images in JPEG format. These undergo downsizing and compression relative to the PhotoCD images.
Vali, Faisal S; Hsi, Alex; Cho, Paul; Parsai, Homayon; Garver, Elizabeth; Garza, Richard
2008-11-06
The Calypso 4D Localization System records prostate motion continuously during radiation treatment. It stores the data across thousands of Excel files. We developed Javascript (JScript) libraries for Windows Script Host (WSH) that use ActiveX Data Objects, OLE Automation and SQL to statistically analyze the data and display the results as a comprehensible Excel table. We then leveraged these libraries in other research to perform vector math on data spread across multiple access databases.
Excoffier, Laurent; Lischer, Heidi E L
2010-05-01
We present here a new version of the Arlequin program available under three different forms: a Windows graphical version (Winarl35), a console version of Arlequin (arlecore), and a specific console version to compute summary statistics (arlsumstat). The command-line versions run under both Linux and Windows. The main innovations of the new version include enhanced outputs in XML format, the possibility to embed graphics displaying computation results directly into output files, and the implementation of a new method to detect loci under selection from genome scans. Command-line versions are designed to handle large series of files, and arlsumstat can be used to generate summary statistics from simulated data sets within an Approximate Bayesian Computation framework. © 2010 Blackwell Publishing Ltd.
Converting laserdisc video to digital video: a demonstration project using brain animations.
Jao, C S; Hier, D B; Brint, S U
1995-01-01
Interactive laserdiscs are of limited value in large group learning situations due to the expense of establishing multiple workstations. The authors implemented an alternative to laserdisc video by using indexed digital video combined with an expert system. High-quality video was captured from a laserdisc player and combined with waveform audio into an audio-video-interleave (AVI) file format in the Microsoft Video-for-Windows environment (Microsoft Corp., Seattle, WA). With the use of an expert system, a knowledge-based computer program provided random access to these indexed AVI files. The program can be played on any multimedia computer without the need for laserdiscs. This system offers a high level of interactive video without the overhead and cost of a laserdisc player.
LLCEDATA and LLCECALC for Windows version 1.0, Volume 1: User`s manual
DOE Office of Scientific and Technical Information (OSTI.GOV)
McFadden, J.G.
LLCEDATA and LLCECALC for Windows are user-friendly computer software programs that work together to determine the proper waste designation, handling, and disposition requirements for Long Length Contaminated Equipment (LLCE). LLCEDATA reads from a variety of data bases to produce an equipment data file (EDF) that represents a snapshot of both the LLCE and the tank it originates from. LLCECALC reads the EDF and a gamma assay (AV2) file that is produced by the Flexible Receiver Gamma Energy Analysis System. LLCECALC performs corrections to the AV2 file as it is being read and characterizes the LLCE. Both programs produce a varietymore » of reports, including a characterization report and a status report. The status report documents each action taken by the user, LLCEDATA, and LLCECALC. Documentation for LLCEDATA and LLCECALC for Windows is available in three volumes. Volume 1 is a user`s manual, which is intended as a quick reference for both LLCEDATA and LLCECALC. Volume 2 is a technical manual, and Volume 3 is a software verification and validation document.« less
Air Traffic Complexity Measurement Environment (ACME): Software User's Guide
NASA Technical Reports Server (NTRS)
1996-01-01
A user's guide for the Air Traffic Complexity Measurement Environment (ACME) software is presented. The ACME consists of two major components, a complexity analysis tool and user interface. The Complexity Analysis Tool (CAT) analyzes complexity off-line, producing data files which may be examined interactively via the Complexity Data Analysis Tool (CDAT). The Complexity Analysis Tool is composed of three independently executing processes that communicate via PVM (Parallel Virtual Machine) and Unix sockets. The Runtime Data Management and Control process (RUNDMC) extracts flight plan and track information from a SAR input file, and sends the information to GARP (Generate Aircraft Routes Process) and CAT (Complexity Analysis Task). GARP in turn generates aircraft trajectories, which are utilized by CAT to calculate sector complexity. CAT writes flight plan, track and complexity data to an output file, which can be examined interactively. The Complexity Data Analysis Tool (CDAT) provides an interactive graphic environment for examining the complexity data produced by the Complexity Analysis Tool (CAT). CDAT can also play back track data extracted from System Analysis Recording (SAR) tapes. The CDAT user interface consists of a primary window, a controls window, and miscellaneous pop-ups. Aircraft track and position data is displayed in the main viewing area of the primary window. The controls window contains miscellaneous control and display items. Complexity data is displayed in pop-up windows. CDAT plays back sector complexity and aircraft track and position data as a function of time. Controls are provided to start and stop playback, adjust the playback rate, and reposition the display to a specified time.
Mars Reconnaissance Orbiter Uplink Analysis Tool
NASA Technical Reports Server (NTRS)
Khanampompan, Teerapat; Gladden, Roy; Fisher, Forest; Hwang, Pauline
2008-01-01
This software analyzes Mars Reconnaissance Orbiter (MRO) orbital geometry with respect to Mars Exploration Rover (MER) contact windows, and is the first tool of its kind designed specifically to support MRO-MER interface coordination. Prior to this automated tool, this analysis was done manually with Excel and the UNIX command line. In total, the process would take approximately 30 minutes for each analysis. The current automated analysis takes less than 30 seconds. This tool resides on the flight machine and uses a PHP interface that does the entire analysis of the input files and takes into account one-way light time from another input file. Input flies are copied over to the proper directories and are dynamically read into the tool s interface. The user can then choose the corresponding input files based on the time frame desired for analysis. After submission of the Web form, the tool merges the two files into a single, time-ordered listing of events for both spacecraft. The times are converted to the same reference time (Earth Transmit Time) by reading in a light time file and performing the calculations necessary to shift the time formats. The program also has the ability to vary the size of the keep-out window on the main page of the analysis tool by inputting a custom time for padding each MRO event time. The parameters on the form are read in and passed to the second page for analysis. Everything is fully coded in PHP and can be accessed by anyone with access to the machine via Web page. This uplink tool will continue to be used for the duration of the MER mission's needs for X-band uplinks. Future missions also can use the tools to check overflight times as well as potential site observation times. Adaptation of the input files to the proper format, and the window keep-out times, would allow for other analyses. Any operations task that uses the idea of keep-out windows will have a use for this program.
IVS Working Group 4: VLBI Data Structures
NASA Astrophysics Data System (ADS)
Gipson, J.
2012-12-01
I present an overview of the "openDB format" for storing, archiving, and processing VLBI data. In this scheme, most VLBI data is stored in NetCDF files. NetCDF has the advantage that there are interfaces to most common computer languages including Fortran, Fortran-90, C, C++, Perl, etc, and the most common operating systems including Linux, Windows, and Mac. The data files for a particular session are organized by special ASCII "wrapper" files which contain pointers to the data files. This allows great flexibility in the processing and analysis of VLBI data. For example it allows you to easily change subsets of the data used in the analysis such as troposphere modeling, ionospheric calibration, editing, and ambiguity resolution. It also allows for extending the types of data used, e.g., source maps. I present a roadmap to transition to this new format. The new format can already be used by VieVS and by the global mode of solve. There are plans in work for other software packages to be able to use the new format.
Context Switching with Multiple Register Windows: A RISC Performance Study
NASA Technical Reports Server (NTRS)
Konsek, Marion B.; Reed, Daniel A.; Watcharawittayakul, Wittaya
1987-01-01
Although previous studies have shown that a large file of overlapping register windows can greatly reduce procedure call/return overhead, the effects of register windows in a multiprogramming environment are poorly understood. This paper investigates the performance of multiprogrammed, reduced instruction set computers (RISCs) as a function of window management strategy. Using an analytic model that reflects context switch and procedure call overheads, we analyze the performance of simple, linearly self-recursive programs. For more complex programs, we present the results of a simulation study. These studies show that a simple strategy that saves all windows prior to a context switch, but restores only a single window following a context switch, performs near optimally.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Walkup, Elizabeth
This software is an analyzer for automated sandbox analysis of malware on the OS X operating system. It runs inside an OS X virtual machine to collect data about what happens when a given file is opened or run. As of August 2014, there was no sandbox software for Mac OS X malware, as it requires different methods from those used on the Windows OS (which most sandboxes are written for). This software adds OS X analysis capabilities to an existing open-source sandbox, Cuckoo Sandbox (http://cuckoosandbox.org/), which previously only worked for Windows. The analyzer itself can take many different typesmore » of files as input: the traditional Mach-O and FAT executables, .app files, zip files, Python scripts, Java archives, and web pages, as well as PDFs and other documents. While the file is running, the analyzer also simulates rudimentary human interaction with clicks and mouse movements in order to bypass the tests some malware use to see if they are being analyzed. The analyzer outputs several different kinds of data: function call traces, network captures, screenshots, and all created and modified files. This work also includes a static analysis Cuckoo module for Mach-O binary files. It extracts file structures, code library imports and exports, and signatures. This data can be used along with the analyzer results to create signatures for malware.« less
Analysts guide: TreeVal for Windows, Version 2.0.
R.D. Fight; J.T. Chmelik; E.A. Coulter
2001-01-01
TreeVal for Windows provides financial information and analysis to support silvicultural decisions in coast Douglas-fir (Pseudotsuga menziesii (Mirb.) Franco). It integrates the effect of growth and yield, management costs, harvesting costs, product and mill type, manufacturing costs, product prices, and product grade premiums. Output files from...
Improving the Taiwan Military’s Disaster Relief Response to Typhoons
2015-06-01
circulation, are mostly westbound. When they reach the vicinity of Taiwan or the Philippines , which are always at the edge of the Pacific subtropical high...files from the POM base case model, one set for each design point. To automate the process of running all the GAMS files, a Windows batch file ( BAT ...is used to call on GAMS to solve each version of the model. The BAT file creates a new directory for each run to hold output, and one of the outputs
SOSPEX, an interactive tool to explore SOFIA spectral cubes
NASA Astrophysics Data System (ADS)
Fadda, Dario; Chambers, Edward T.
2018-01-01
We present SOSPEX (SOFIA SPectral EXplorer), an interactive tool to visualize and analyze spectral cubes obtained with the FIFI-LS and GREAT instruments onboard the SOFIA Infrared Observatory. This software package is written in Python 3 and it is available either through Github or Anaconda.Through this GUI it is possible to explore directly the spectral cubes produced by the SOFIA pipeline and archived in the SOFIA Science Archive. Spectral cubes are visualized showing their spatial and spectral dimensions in two different windows. By selecting a part of the spectrum, the flux from the corresponding slice of the cube is visualized in the spatial window. On the other hand, it is possible to define apertures on the spatial window to show the corresponding spectral energy distribution in the spectral window.Flux isocontours can be overlapped to external images in the spatial window while line names, atmospheric transmission, or external spectra can be overplotted on the spectral window. Atmospheric models with specific parameters can be retrieved, compared to the spectra and applied to the uncorrected FIFI-LS cubes in the cases where the standard values give unsatisfactory results. Subcubes can be selected and saved as FITS files by cropping or cutting the original cubes. Lines and continuum can be fitted in the spectral window saving the results in Jyson files which can be reloaded later. Finally, in the case of spatially extended observations, it is possible to compute spectral momenta as a function of the position to obtain velocity dispersion maps or velocity diagrams.
NASA Technical Reports Server (NTRS)
Barry, Matthew R.
2006-01-01
The X-Windows Process Validation Table (PVT) Widget Class ( Class is used here in the object-oriented-programming sense of the word) was devised to simplify the task of implementing network registration services for Information Sharing Protocol (ISP) graphical-user-interface (GUI) computer programs. Heretofore, ISP PVT programming tasks have required many method calls to identify, query, and interpret the connections and messages exchanged between a client and a PVT server. Normally, programmers have utilized direct access to UNIX socket libraries to implement the PVT protocol queries, necessitating the use of many lines of source code to perform frequent tasks. Now, the X-Windows PVT Widget Class encapsulates ISP client server network registration management tasks within the framework of an X Windows widget. Use of the widget framework enables an X Windows GUI program to interact with PVT services in an abstract way and in the same manner as that of other graphical widgets, making it easier to program PVT clients. Wrapping the PVT services inside the widget framework enables a programmer to treat a PVT server interface as though it were a GUI. Moreover, an alternate subclass could implement another service in a widget of the same type. This program was written by Matthew R. Barry of United Space Alliance for Johnson Space Center. For further information, contact the Johnson Technology Transfer Office at (281) 483-3809. MSC-23582 Shuttle Data Center File- Processing Tool in Java A Java-language computer program has been written to facilitate mining of data in files in the Shuttle Data Center (SDC) archives. This program can be executed on a variety of workstations or via Web-browser programs. This program is partly similar to prior C-language programs used for the same purpose, while differing from those programs in that it exploits the platform-neutrality of Java in implementing several features that are important for analysis of large sets of time-series data. The program supports regular expression queries of SDC archive files, reads the files, interleaves the time-stamped samples according to a chosen output, then transforms the results into that format. A user can choose among a variety of output file formats that are useful for diverse purposes, including plotting, Markov modeling, multivariate density estimation, and wavelet multiresolution analysis, as well as for playback of data in support of simulation and testing.
ListingAnalyst: A program for analyzing the main output file from MODFLOW
Winston, Richard B.; Paulinski, Scott
2014-01-01
ListingAnalyst is a Windows® program for viewing the main output file from MODFLOW-2005, MODFLOW-NWT, or MODFLOW-LGR. It organizes and displays large files quickly without using excessive memory. The sections and subsections of the file are displayed in a tree-view control, which allows the user to navigate quickly to desired locations in the files. ListingAnalyst gathers error and warning messages scattered throughout the main output file and displays them all together in an error and a warning tab. A grid view displays tables in a readable format and allows the user to copy the table into a spreadsheet. The user can also search the file for terms of interest.
Alview: Portable Software for Viewing Sequence Reads in BAM Formatted Files.
Finney, Richard P; Chen, Qing-Rong; Nguyen, Cu V; Hsu, Chih Hao; Yan, Chunhua; Hu, Ying; Abawi, Massih; Bian, Xiaopeng; Meerzaman, Daoud M
2015-01-01
The name Alview is a contraction of the term Alignment Viewer. Alview is a compiled to native architecture software tool for visualizing the alignment of sequencing data. Inputs are files of short-read sequences aligned to a reference genome in the SAM/BAM format and files containing reference genome data. Outputs are visualizations of these aligned short reads. Alview is written in portable C with optional graphical user interface (GUI) code written in C, C++, and Objective-C. The application can run in three different ways: as a web server, as a command line tool, or as a native, GUI program. Alview is compatible with Microsoft Windows, Linux, and Apple OS X. It is available as a web demo at https://cgwb.nci.nih.gov/cgi-bin/alview. The source code and Windows/Mac/Linux executables are available via https://github.com/NCIP/alview.
LTCP 2D Graphical User Interface. Application Description and User's Guide
NASA Technical Reports Server (NTRS)
Ball, Robert; Navaz, Homayun K.
1996-01-01
A graphical user interface (GUI) written for NASA's LTCP (Liquid Thrust Chamber Performance) 2 dimensional computational fluid dynamic code is described. The GUI is written in C++ for a desktop personal computer running under a Microsoft Windows operating environment. Through the use of common and familiar dialog boxes, features, and tools, the user can easily and quickly create and modify input files for the LTCP code. In addition, old input files used with the LTCP code can be opened and modified using the GUI. The application is written in C++ for a desktop personal computer running under a Microsoft Windows operating environment. The program and its capabilities are presented, followed by a detailed description of each menu selection and the method of creating an input file for LTCP. A cross reference is included to help experienced users quickly find the variables which commonly need changes. Finally, the system requirements and installation instructions are provided.
Using Parameters of Dynamic Pulse Function for 3d Modeling in LOD3 Based on Random Textures
NASA Astrophysics Data System (ADS)
Alizadehashrafi, B.
2015-12-01
The pulse function (PF) is a technique based on procedural preprocessing system to generate a computerized virtual photo of the façade with in a fixed size square(Alizadehashrafi et al., 2009, Musliman et al., 2010). Dynamic Pulse Function (DPF) is an enhanced version of PF which can create the final photo, proportional to real geometry. This can avoid distortion while projecting the computerized photo on the generated 3D model(Alizadehashrafi and Rahman, 2013). The challenging issue that might be handled for having 3D model in LoD3 rather than LOD2, is the final aim that have been achieved in this paper. In the technique based DPF the geometries of the windows and doors are saved in an XML file schema which does not have any connections with the 3D model in LoD2 and CityGML format. In this research the parameters of Dynamic Pulse Functions are utilized via Ruby programming language in SketchUp Trimble to generate (exact position and deepness) the windows and doors automatically in LoD3 based on the same concept of DPF. The advantage of this technique is automatic generation of huge number of similar geometries e.g. windows by utilizing parameters of DPF along with defining entities and window layers. In case of converting the SKP file to CityGML via FME software or CityGML plugins the 3D model contains the semantic database about the entities and window layers which can connect the CityGML to MySQL(Alizadehashrafi and Baig, 2014). The concept behind DPF, is to use logical operations to project the texture on the background image which is dynamically proportional to real geometry. The process of projection is based on two vertical and horizontal dynamic pulses starting from upper-left corner of the background wall in down and right directions respectively based on image coordinate system. The logical one/zero on the intersections of two vertical and horizontal dynamic pulses projects/does not project the texture on the background image. It is possible to define priority for each layer. For instance the priority of the door layer can be higher than window layer which means that window texture cannot be projected on the door layer. Orthogonal and rectified perpendicular symmetric photos of the 3D objects that are proportional to the real façade geometry must be utilized for the generation of the output frame for DPF. The DPF produces very high quality and small data size of output image files in quite smaller dimension compare with the photorealistic texturing method. The disadvantage of DPF is its preprocessing method to generate output image file rather than online processing to generate the texture within the 3D environment such as CityGML. Furthermore the result of DPF can be utilized for 3D model in LOD2 rather than LOD3. In the current work the random textures of the window layers are created based on parameters of DPF within Ruby console of SketchUp Trimble to generate the deeper geometries of the windows and their exact position on the façade automatically along with random textures to increase Level of Realism (LoR)(Scarpino, 2010). As the output frame in DPF is proportional to real geometry (height and width of the façade) it is possible to query the XML database and convert them to units such as meter automatically. In this technique, the perpendicular terrestrial photo from the façade is rectified by employing projective transformation based on the frame which is in constrain proportion to real geometry. The rectified photos which are not suitable for texturing but necessary for measuring, can be resized in constrain proportion to real geometry before measuring process. Height and width of windows, doors, horizontal and vertical distance between windows from upper left corner of the photo dimensions of doors and windows are parameters that should be measured to run the program as a plugins in SketchUp Trimble. The system can use these parameters and texture file names and file paths to create the façade semi-automatically. To avoid leaning geometry the textures of windows, doors and etc, should be cropped and rectified from perpendicular photos, so that they can be used in the program to create the whole façade along with its geometries. Texture enhancement should be done in advance such as removing disturbing objects, exposure setting, left-right up-down transformation, and so on. In fact, the quality, small data size, scale and semantic database for each façade are the prominent advantages of this method.
76 FR 75898 - Sport Fishing and Boating Partnership Council
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-05
... following formats: One hard copy with original signature, and one electronic copy via email (acceptable file format: Adobe Acrobat PDF, WordPerfect, MS Word, MS PowerPoint, or Rich Text files in IBM-PC/Windows 98/2000/XP format). Please submit your statement to Douglas Hobbs, Council Coordinator (see FOR FURTHER...
Windows VPN Set Up | High-Performance Computing | NREL
it in your My Documents folder Configure the client software using that conf file Start the TEXT NEEDED Configure the Client Software Start the Endian Connect App. You'll configure the connection using the hpcvpn-win.conf file, uncheck the "save password" link, and add your UserID. Start
View_SPECPR: Software for Plotting Spectra (Installation Manual and User's Guide, Version 1.2)
Kokaly, Raymond F.
2008-01-01
This document describes procedures for installing and using the 'View_SPECPR' software system to plot spectra stored in SPECPR (SPECtrum Processing Routines) files. The View_SPECPR software is comprised of programs written in IDL (Interactive Data Language) that run within the ENVI (ENvironment for Visualizing Images) image processing system. SPECPR files are used by earth-remote-sensing scientists and planetary scientists for storing spectra collected by laboratory, field, and remote sensing instruments. A widely distributed SPECPR file is the U.S. Geological Survey (USGS) spectral library that contains thousands of spectra of minerals, vegetation, and man-made materials (Clark and others, 2007). SPECPR files contain reflectance data and associated wavelength and spectral resolution data, as well as meta-data on the time and date of collection and spectrometer settings. Furthermore, the SPECPR file automatically tracks changes to data records through its 'history' fields. For more details on the format and content of SPECPR files, see Clark (1993). For more details on ENVI, see ITT (2008). This program has been updated using an ENVI 4.5/IDL7.0 full license operating on a Windows XP operating system and requires the installation of the iTools components of IDL7.0; however, this program should work with full licenses on UNIX/LINUX systems. This software has not been tested with ENVI licenses on Windows Vista or Apple Operating Systems.
SUNREL FAQs | Buildings | NREL
or wind effects are modeled). This option is useful when modeling surfaces that do not see the sun fraction in the Walls section. The AMBIENT zone is useful for exterior walls that do no see the sun or have little effect from the sun. Q: How are glazing data files generated using Window 4.1 or Window 5.X? A
75 FR 47624 - Sport Fishing and Boating Partnership Council
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-06
... Coordinator in both of the following formats: One hard copy with original signature, and one electronic copy via e- mail (acceptable file format: Adobe Acrobat PDF, WordPerfect, MS Word, MS PowerPoint, or Rich Text files in IBM-PC/Windows 98/2000/XP format). In order to attend this meeting, you must register by...
BAOBAB: a Java editor for large phylogenetic trees.
Dutheil, J; Galtier, N
2002-06-01
BAOBAB is a Java user interface dedicated to viewing and editing large phylogenetic trees. Original features include: (i) a colour-mediated overview of magnified subtrees; (ii) copy/cut/paste of (sub)trees within or between windows; (iii) compressing/ uncompressing subtrees; and (iv) managing sequence files together with tree files. http://www.univ-montp2.fr/~genetix/.
A Study of Gaps in Cyber Defense Automation
2015-10-18
to lowercase. Next, the normalized file is tokenized using an n -length window. These n -tokens are then hashed into a Bloom filter for that file. In the...readily available to most developers. However, with a complexity of O(N2) where N is the number of files (or the number of functions if using function...that measure the impact of each feature on the website’s chances of becoming compromised, and the top N features are submitted to the classification
MAT - MULTI-ATTRIBUTE TASK BATTERY FOR HUMAN OPERATOR WORKLOAD AND STRATEGIC BEHAVIOR RESEARCH
NASA Technical Reports Server (NTRS)
Comstock, J. R.
1994-01-01
MAT, a Multi-Attribute Task battery, gives the researcher the capability of performing multi-task workload and performance experiments. The battery provides a benchmark set of tasks for use in a wide range of laboratory studies of operator performance and workload. MAT incorporates tasks analogous to activities that aircraft crew members perform in flight, while providing a high degree of experiment control, performance data on each subtask, and freedom to use non-pilot test subjects. The MAT battery primary display is composed of four separate task windows which are as follows: a monitoring task window which includes gauges and warning lights, a tracking task window for the demands of manual control, a communication task window to simulate air traffic control communications, and a resource management task window which permits maintaining target levels on a fuel management task. In addition, a scheduling task window gives the researcher information about future task demands. The battery also provides the option of manual or automated control of tasks. The task generates performance data for each subtask. The task battery may be paused and onscreen workload rating scales presented to the subject. The MAT battery was designed to use a serially linked second computer to generate the voice messages for the Communications task. The MATREMX program and support files, which are included in the MAT package, were designed to work with the Heath Voice Card (Model HV-2000, available through the Heath Company, Benton Harbor, Michigan 49022); however, the MATREMX program and support files may easily be modified to work with other voice synthesizer or digitizer cards. The MAT battery task computer may also be used independent of the voice computer if no computer synthesized voice messages are desired or if some other method of presenting auditory messages is devised. MAT is written in QuickBasic and assembly language for IBM PC series and compatible computers running MS-DOS. The code in MAT is written for Microsoft QuickBasic 4.5 and Microsoft Macro Assembler 5.1. This package requires a joystick and EGA or VGA color graphics. An 80286, 386, or 486 processor machine is highly recommended. The standard distribution medium for MAT is a 5.25 inch 360K MS-DOS format diskette. The files are compressed using the PKZIP file compression utility. PKUNZIP is included on the distribution diskette. MAT was developed in 1992. IBM PC is a registered trademark of International Business Machines. MS-DOS, Microsoft QuickBasic, and Microsoft Macro Assembler are registered trademarks of Microsoft Corporation. PKZIP and PKUNZIP are registered trademarks of PKWare, Inc.
Installation and management of the SPS and LEP control system computers
NASA Astrophysics Data System (ADS)
Bland, Alastair
1994-12-01
Control of the CERN SPS and LEP accelerators and service equipment on the two CERN main sites is performed via workstations, file servers, Process Control Assemblies (PCAs) and Device Stub Controllers (DSCs). This paper describes the methods and tools that have been developed to manage the file servers, PCAs and DSCs since the LEP startup in 1989. There are five operational DECstation 5000s used as file servers and boot servers for the PCAs and DSCs. The PCAs consist of 90 SCO Xenix 386 PCs, 40 LynxOS 486 PCs and more than 40 older NORD 100s. The DSCs consist of 90 OS-968030 VME crates and 10 LynxOS 68030 VME crates. In addition there are over 100 development systems. The controls group is responsible for installing the computers, starting all the user processes and ensuring that the computers and the processes run correctly. The operators in the SPS/LEP control room and the Services control room have a Motif-based X window program which gives them, in real time, the state of all the computers and allows them to solve problems or reboot them.
Umeda, Akira; Iwata, Yasushi; Okada, Yasumasa; Shimada, Megumi; Baba, Akiyasu; Minatogawa, Yasuyuki; Yamada, Takayasu; Chino, Masao; Watanabe, Takafumi; Akaishi, Makoto
2004-12-01
The high cost of digital echocardiographs and the large size of data files hinder the adoption of remote diagnosis of digitized echocardiography data. We have developed a low-cost digital filing system for echocardiography data. In this system, data from a conventional analog echocardiograph are captured using a personal computer (PC) equipped with an analog-to-digital converter board. Motion picture data are promptly compressed using a moving pictures expert group (MPEG) 4 codec. The digitized data with preliminary reports obtained in a rural hospital are then sent to cardiologists at distant urban general hospitals via the internet. The cardiologists can evaluate the data using widely available movie-viewing software (Windows Media Player). The diagnostic accuracy of this double-check system was confirmed by comparison with ordinary super-VHS videotapes. We have demonstrated that digitization of echocardiography data from a conventional analog echocardiograph and MPEG 4 compression can be performed using an ordinary PC-based system, and that this system enables highly efficient digital storage and remote diagnosis at low cost.
NASA Technical Reports Server (NTRS)
Allman, Mark; Ostermann, Shawn; Kruse, Hans
1996-01-01
In several experiments using NASA's Advanced Communications Technology Satellite (ACTS), investigators have reported disappointing throughput using the transmission control protocol/Internet protocol (TCP/IP) protocol suite over 1.536Mbit/sec (T1) satellite circuits. A detailed analysis of file transfer protocol (FTP) file transfers reveals that both the TCP window size and the TCP 'slow starter' algorithm contribute to the observed limits in throughput. In this paper we summarize the experimental and and theoretical analysis of the throughput limit imposed by TCP on the satellite circuit. We then discuss in detail the implementation of a multi-socket FTP, XFTP client and server. XFTP has been tested using the ACTS system. Finally, we discuss a preliminary set of tests on a link with non-zero bit error rates. XFTP shows promising performance under these conditions, suggesting the possibility that a multi-socket application may be less effected by bit errors than a single, large-window TCP connection.
Windows .NET Network Distributed Basic Local Alignment Search Toolkit (W.ND-BLAST)
Dowd, Scot E; Zaragoza, Joaquin; Rodriguez, Javier R; Oliver, Melvin J; Payton, Paxton R
2005-01-01
Background BLAST is one of the most common and useful tools for Genetic Research. This paper describes a software application we have termed Windows .NET Distributed Basic Local Alignment Search Toolkit (W.ND-BLAST), which enhances the BLAST utility by improving usability, fault recovery, and scalability in a Windows desktop environment. Our goal was to develop an easy to use, fault tolerant, high-throughput BLAST solution that incorporates a comprehensive BLAST result viewer with curation and annotation functionality. Results W.ND-BLAST is a comprehensive Windows-based software toolkit that targets researchers, including those with minimal computer skills, and provides the ability increase the performance of BLAST by distributing BLAST queries to any number of Windows based machines across local area networks (LAN). W.ND-BLAST provides intuitive Graphic User Interfaces (GUI) for BLAST database creation, BLAST execution, BLAST output evaluation and BLAST result exportation. This software also provides several layers of fault tolerance and fault recovery to prevent loss of data if nodes or master machines fail. This paper lays out the functionality of W.ND-BLAST. W.ND-BLAST displays close to 100% performance efficiency when distributing tasks to 12 remote computers of the same performance class. A high throughput BLAST job which took 662.68 minutes (11 hours) on one average machine was completed in 44.97 minutes when distributed to 17 nodes, which included lower performance class machines. Finally, there is a comprehensive high-throughput BLAST Output Viewer (BOV) and Annotation Engine components, which provides comprehensive exportation of BLAST hits to text files, annotated fasta files, tables, or association files. Conclusion W.ND-BLAST provides an interactive tool that allows scientists to easily utilizing their available computing resources for high throughput and comprehensive sequence analyses. The install package for W.ND-BLAST is freely downloadable from . With registration the software is free, installation, networking, and usage instructions are provided as well as a support forum. PMID:15819992
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fox, Kevin
The software provides a simple web api to allow users to request a time window where a file will not be removed from cache. HPSS provides the concept of a "purge lock". When a purge lock is set on a file, the file will not be removed from disk, entering tape only state. A lot of network file protocols assume a file is on disk so it is good to purge lock a file before transferring using one of those protocols. HPSS's purge lock system is very coarse grained though. A file is either purge locked or not. Nothing enforcesmore » quotas, timely unlocking of purge locks, or managing the races inherent with multiple users wanting to lock/unlock the same file. The Purge Lock Server lets you, through a simple REST API, specify a list of files to purge lock and an expire time, and the system will ensure things happen properly.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-03
... meeting. Written statements should be supplied to the DFO in the following formats: One hard copy with original signature and one electronic copy via e-mail (acceptable file format: Adobe Acrobat PDF, MS Word, WordPerfect, MS PowerPoint, or Rich Text files in IBM-PC/Windows 98/2000/XP format). Submitters are...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-25
... their consideration. Written statements should be supplied to the DFO in the following formats: one hard copy with original signature, and one electronic copy via e-mail (acceptable file format: Adobe Acrobat PDF, WordPerfect, MS Word, MS PowerPoint, or Rich Text files in IBM-PC/ Windows 98/2000/XP format...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-01-29
... statements should be supplied to the DFO in the following formats: one hard copy with original signature, and one electronic copy via e-mail (acceptable file format: Adobe Acrobat PDF, WordPerfect, MS Word, MS PowerPoint, or Rich Text files in IBM-PC/Windows 98/2000/XP format). Submitters are asked to provide...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-30
... should be supplied to the DFO in the following formats: One hard copy with original signature and one electronic copy via e-mail (acceptable file format: Adobe Acrobat PDF, MS Word, WordPerfect, MS PowerPoint, or Rich Text files in IBM-PC/Windows 98/2000/XP format). Submitters are asked to provide electronic...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-21
... be supplied to the DFO in the following formats: One hard copy with original signature, and one electronic copy via e-mail (acceptable file format: Adobe Acrobat PDF, WordPerfect, MS Word, MS PowerPoint, or Rich Text files in IBM-PC/ Windows 98/2000/XP format). Submitters are requested to provide two...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-30
... supplied to the DFO in the following formats: One hard copy with original signature, and one electronic copy via e-mail (acceptable file format: Adobe Acrobat PDF, WordPerfect, MS Word, MS PowerPoint, or Rich Text files in IBM-PC/ Windows 98/2000/XP format). Submitters are requested to provide two versions...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-01-11
... supplied to the DFO in the following formats: one hard copy with original signature and one electronic copy via e-mail (acceptable file format: Adobe Acrobat PDF, MS Word, WordPerfect, MS PowerPoint, or Rich Text files in IBM-PC/Windows 98/2000/XP format). Submitters are asked to provide versions of each...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-25
... statements should be supplied to the DFO in the following formats: One hard copy with original signature and one electronic copy via e-mail (acceptable file format: Adobe Acrobat PDF, WordPerfect, MS Word, MS PowerPoint, or Rich Text files in IBM-PC/Windows 98/2000/XP format). Submitters are requested to provide...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-08
.... Written statements should be supplied to the DFO in the following formats: one hard copy with original signature, and one electronic copy via e-mail (acceptable file format: Adobe Acrobat PDF, WordPerfect, MS Word, MS PowerPoint, or Rich Text files in IBM-PC/Windows 98/2000/XP format). Submitters are asked to...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-01
... their consideration. Written statements should be supplied to the DFO in the following formats: one hard copy with original signature, and one electronic copy via e-mail (acceptable file format: Adobe Acrobat PDF, WordPerfect, MS Word, MS PowerPoint, or Rich Text files in IBM-PC/ Windows 98/2000/XP format...
47 CFR 73.208 - Reference points and distance computations.
Code of Federal Regulations, 2011 CFR
2011-10-01
... SERVICES RADIO BROADCAST SERVICES FM Broadcast Stations § 73.208 Reference points and distance computations... filed no later than: (i) The last day of a filing window if the application is for a new FM facility or...(d) and 73.3573(e) if the application is for a new FM facility or a major change in the reserved band...
47 CFR 73.208 - Reference points and distance computations.
Code of Federal Regulations, 2010 CFR
2010-10-01
... SERVICES RADIO BROADCAST SERVICES FM Broadcast Stations § 73.208 Reference points and distance computations... filed no later than: (i) The last day of a filing window if the application is for a new FM facility or...(d) and 73.3573(e) if the application is for a new FM facility or a major change in the reserved band...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-21
.... The commenter also argues that, in the event that only one applicant places a bid on a permit, that...). The Commission makes no warranty whatsoever with respect to the FCC Auction System. In no event shall..., 2011 Short-Form Application (FCC Form 175) Filing Window Opens--January 31, 2011; 12 noon ET Short-Form...
LLCEDATA and LLCECALC for Windows version 1.0, Volume 3: Software verification and validation
DOE Office of Scientific and Technical Information (OSTI.GOV)
McFadden, J.G.
1998-09-04
LLCEDATA and LLCECALC for Windows are user-friendly computer software programs that work together to determine the proper waste designation, handling, and disposition requirements for Long Length Contaminated Equipment (LLCE). LLCEDATA reads from a variety of data bases to produce an equipment data file(EDF) that represents a snapshot of both the LLCE and the tank from which it originates. LLCECALC reads the EDF and the gamma assay file (AV2) that is produced by the flexible Receiver Gamma Energy Analysis System. LLCECALC performs corrections to the AV2 file as it is being read and characterizes the LLCE. Both programs produce a varietymore » of reports, including a characterization report and a status report. The status report documents each action taken by the user, LLCEDATA, and LLCECALC. Documentation for LLCEDATA and LLCECALC for Windows is available in three volumes. Volume 1 is a user`s manual, which is intended as a quick reference for both LLCEDATA and LLCECALC. Volume 2 is a technical manual, which discusses system limitations and provides recommendations to the LLCE process. Volume 3 documents LLCEDATA and LLCECALC`s verification and validation. Two of the three installation test cases, from Volume 1, are independently confirmed. Data bases used in LLCEDATA are verified and referenced. Both phases of LLCECALC process gamma and characterization, are extensively tested to verify that the methodology and algorithms used are correct.« less
Standards for efficient employment of wide-area motion imagery (WAMI) sensors
NASA Astrophysics Data System (ADS)
Randall, L. Scott; Maenner, Paul F.
2013-05-01
Airborne Wide Area Motion Imagery (WAMI) sensors provide the opportunity for continuous high-resolution surveillance of geographic areas covering tens of square kilometers. This is both a blessing and a curse. Data volumes from "gigapixel-class" WAMI sensors are orders of magnitude greater than for traditional "megapixel-class" video sensors. The amount of data greatly exceeds the capacities of downlinks to ground stations, and even if this were not true, the geographic coverage is too large for effective human monitoring. Although collected motion imagery is recorded on the platform, typically only small "windows" of the full field of view are transmitted to the ground; the full set of collected data can be retrieved from the recording device only after the mission has concluded. Thus, the WAMI environment presents several difficulties: (1) data is too massive for downlink; (2) human operator selection and control of the video windows may not be effective; (3) post-mission storage and dissemination may be limited by inefficient file formats; and (4) unique system implementation characteristics may thwart exploitation by available analysis tools. To address these issues, the National Geospatial-Intelligence Agency's Motion Imagery Standards Board (MISB) is developing relevant standard data exchange formats: (1) moving target indicator (MTI) and tracking metadata to support tipping and cueing of WAMI windows using "watch boxes" and "trip wires"; (2) control channel commands for positioning the windows within the full WAMI field of view; and (3) a full-field-of-view spatiotemporal tiled file format for efficient storage, retrieval, and dissemination. The authors previously provided an overview of this suite of standards. This paper describes the latest progress, with specific concentration on a detailed description of the spatiotemporal tiled file format.
Escott, Edward J; Rubinstein, David
2004-01-01
It is often necessary for radiologists to use digital images in presentations and conferences. Most imaging modalities produce images in the Digital Imaging and Communications in Medicine (DICOM) format. The image files tend to be large and thus cannot be directly imported into most presentation software, such as Microsoft PowerPoint; the large files also consume storage space. There are many free programs that allow viewing and processing of these files on a personal computer, including conversion to more common file formats such as the Joint Photographic Experts Group (JPEG) format. Free DICOM image viewing and processing software for computers running on the Microsoft Windows operating system has already been evaluated. However, many people use the Macintosh (Apple Computer) platform, and a number of programs are available for these users. The World Wide Web was searched for free DICOM image viewing or processing software that was designed for the Macintosh platform or is written in Java and is therefore platform independent. The features of these programs and their usability were evaluated. There are many free programs for the Macintosh platform that enable viewing and processing of DICOM images. (c) RSNA, 2004.
1990-12-01
keys 7 Executing PBPKSIM 10 Main Menu 12 File Selection 13 Data 13 simulation 13 All 14 sTatistics 14 Change directory 14 dos Shell 15 eXit 15 Data...the PBPKSIM program are based upon the window design seen here: TITLE I MENU BAR I INFORMATION LINE I I I IMIN DISPLAY AREAI1 1 I I I I I I I STATUS...AREAI Title shows the location of the program by supplying the name of the window being exeLuted. Menu Bar displays the other windows or other
Chow, James C.L.; Grigorov, Grigor N.; Yazdani, Nuri
2006-01-01
A custom‐made computer program, SWIMRT, to construct “multileaf collimator (MLC) machine” file for intensity‐modulated radiotherapy (IMRT) fluence maps was developed using MATLAB® and the sliding window algorithm. The user can either import a fluence map with a graphical file format created by an external treatment‐planning system such as Pinnacle3 or create his or her own fluence map using the matrix editor in the program. Through comprehensive calibrations of the dose and the dimension of the imported fluence field, the user can use associated image‐processing tools such as field resizing and edge trimming to modify the imported map. When the processed fluence map is suitable, a “MLC machine” file is generated for our Varian 21 EX linear accelerator with a 120‐leaf Millennium MLC. This machine file is transferred to the MLC console of the LINAC to control the continuous motions of the leaves during beam irradiation. An IMRT field is then irradiated with the 2D intensity profiles, and the irradiated profiles are compared to the imported or modified fluence map. This program was verified and tested using film dosimetry to address the following uncertainties: (1) the mechanical limitation due to the leaf width and maximum traveling speed, and (2) the dosimetric limitation due to the leaf leakage/transmission and penumbra effect. Because the fluence map can be edited, resized, and processed according to the requirement of a study, SWIMRT is essential in studying and investigating the IMRT technique using the sliding window algorithm. Using this program, future work on the algorithm may include redistributing the time space between segmental fields to enhance the fluence resolution, and readjusting the timing of each leaf during delivery to avoid small fields. Possible clinical utilities and examples for SWIMRT are given in this paper. PACS numbers: 87.53.Kn, 87.53.St, 87.53.Uv PMID:17533330
Configuration Management File Manager Developed for Numerical Propulsion System Simulation
NASA Technical Reports Server (NTRS)
Follen, Gregory J.
1997-01-01
One of the objectives of the High Performance Computing and Communication Project's (HPCCP) Numerical Propulsion System Simulation (NPSS) is to provide a common and consistent way to manage applications, data, and engine simulations. The NPSS Configuration Management (CM) File Manager integrated with the Common Desktop Environment (CDE) window management system provides a common look and feel for the configuration management of data, applications, and engine simulations for U.S. engine companies. In addition, CM File Manager provides tools to manage a simulation. Features include managing input files, output files, textual notes, and any other material normally associated with simulation. The CM File Manager includes a generic configuration management Application Program Interface (API) that can be adapted for the configuration management repositories of any U.S. engine company.
2013-11-01
may be considered moderately suspicious. [20, 21, 22 and 23] PID 1580 (jqs.exe) is using port 5152, a port associated to with Java Quick Starter [26...spoolsv.exe 0x01000000 True False True \\WINDOWS\\system32\\spoolsv.exe 1580 jqs.exe 0x00400000 True False True \\Program Files\\ Java \\jre6\\bin\\jqs.exe 1664...Files\\ Java \\ Java Update\\jusched.exe 1816 VMUpgradeHelp er 0x00400000 True False True \\Program Files\\VMware\\VMware Tools\\VMUpgradeHelper.exe 1872
DSN command system Mark III-78. [data processing
NASA Technical Reports Server (NTRS)
Stinnett, W. G.
1978-01-01
The Deep Space Network command Mark III-78 data processing system includes a capability for a store-and-forward handling method. The functions of (1) storing the command files at a Deep Space station; (2) attaching the files to a queue; and (3) radiating the commands to the spacecraft are straightforward. However, the total data processing capability is a result of assuming worst case, failure-recovery, or nonnominal operating conditions. Optional data processing functions include: file erase, clearing the queue, suspend radiation, command abort, resume command radiation, and close window time override.
PCDAQ, A Windows Based DAQ System
NASA Astrophysics Data System (ADS)
Hogan, Gary
1998-10-01
PCDAQ is a Windows NT based general DAQ/Analysis/Monte Carlo shell developed as part of the Proton Radiography project at LANL (Los Alamos National Laboratory). It has been adopted by experiments outside of the Proton Radiography project at Brookhaven National Laboratory (BNL) and at LANL. The program provides DAQ, Monte Carlo, and replay (disk file input) modes. Data can be read from hardware (CAMAC) or other programs (ActiveX servers). Future versions will read VME. User supplied data analysis routines can be written in Fortran, C++, or Visual Basic. Histogramming, testing, and plotting packages are provided. Histogram data can be exported to spreadsheets or analyzed in user supplied programs. Plots can be copied and pasted as bitmap objects into other Windows programs or printed. A text database keyed by the run number is provided. Extensive software control flags are provided so that the user can control the flow of data through the program. Control flags can be set either in script command files or interactively. The program can be remotely controlled and data accessed over the Internet through its ActiveX DCOM interface.
LACIE performance predictor final operational capability program description, volume 2
NASA Technical Reports Server (NTRS)
1976-01-01
Given the swath table files, the segment set for one country and cloud cover data, the SAGE program determines how many times and under what conditions each segment is accessed by satellites. The program writes a record for each segment on a data file which contains the pertinent acquisition data. The weather data file can also be generated from a NASA supplied tape. The Segment Acquisition Selector Program (SACS) selects data from the segment reference file based upon data input manually and from a crop window file. It writes the extracted data to a data acquisition file and prints two summary reports. The POUT program reads from associated LACIE files and produces printed reports. The major types of reports that can be produced are: (1) Substrate Reference Data Reports, (2) Population Mean, Standard Deviation and Histogram Reports, (3) Histograms of Monte Carlo Statistics Reports, and (4) Frequency of Sample Segment Acquisitions Reports.
FD_BH: a program for simulating electromagnetic waves from a borehole antenna
Ellefsen, Karl J.
2002-01-01
Program FD_BH is used to simulate the electromagnetic waves generated by an antenna in a borehole. The model representing the antenna may include metallic parts, a coaxial cable as a feed to the driving point, and resistive loading. The program is written in the C programming language, and the program has been tested on both the Windows and the UNIX operating systems. This Open-File Report describes • The contents and organization of the Zip file (section 2). • The program files, the installation of the program, the input files, and the execution of the program (section 3). • Address to which suggestions for improving the program may be sent (section 4).
Hybrid cryptosystem for image file using elgamal and double playfair cipher algorithm
NASA Astrophysics Data System (ADS)
Hardi, S. M.; Tarigan, J. T.; Safrina, N.
2018-03-01
In this paper, we present an implementation of an image file encryption using hybrid cryptography. We chose ElGamal algorithm to perform asymmetric encryption and Double Playfair for the symmetric encryption. Our objective is to show that these algorithms are capable to encrypt an image file with an acceptable running time and encrypted file size while maintaining the level of security. The application was built using C# programming language and ran as a stand alone desktop application under Windows Operating System. Our test shows that the system is capable to encrypt an image with a resolution of 500×500 to a size of 976 kilobytes with an acceptable running time.
Analysis towards VMEM File of a Suspended Virtual Machine
NASA Astrophysics Data System (ADS)
Song, Zheng; Jin, Bo; Sun, Yongqing
With the popularity of virtual machines, forensic investigators are challenged with more complicated situations, among which discovering the evidences in virtualized environment is of significant importance. This paper mainly analyzes the file suffixed with .vmem in VMware Workstation, which stores all pseudo-physical memory into an image. The internal file structure of .vmem file is studied and disclosed. Key information about processes and threads of a suspended virtual machine is revealed. Further investigation into the Windows XP SP3 heap contents is conducted and a proof-of-concept tool is provided. Different methods to obtain forensic memory images are introduced, with both advantages and limits analyzed. We conclude with an outlook.
An object oriented fully 3D tomography visual toolkit.
Agostinelli, S; Paoli, G
2001-04-01
In this paper we present a modern object oriented component object model (COMM) C + + toolkit dedicated to fully 3D cone-beam tomography. The toolkit allows the display and visual manipulation of analytical phantoms, projection sets and volumetric data through a standard Windows graphical user interface. Data input/output is performed using proprietary file formats but import/export of industry standard file formats, including raw binary, Windows bitmap and AVI, ACR/NEMA DICOMM 3 and NCSA HDF is available. At the time of writing built-in implemented data manipulators include a basic phantom ray-tracer and a Matrox Genesis frame grabbing facility. A COMM plug-in interface is provided for user-defined custom backprojector algorithms: a simple Feldkamp ActiveX control, including source code, is provided as an example; our fast Feldkamp plug-in is also available.
XpressWare Installation User guide
NASA Astrophysics Data System (ADS)
Duffey, K. P.
XpressWare is a set of X terminal software, released by Tektronix Inc, that accommodates the X Window system on a range of host computers. The software comprises boot files (the X server image), configuration files, fonts, and font tools to support the X terminal. The files can be installed on one host or distributed across multiple hosts The purpose of this guide is to present the system or network administrator with a step-by-step account of how to install XpressWare, and how subsequently to configure the X terminals appropriately for the environment in which they operate.
NASA Astrophysics Data System (ADS)
Umansky, Moti; Weihs, Daphne
2012-08-01
In many physical and biophysical studies, single-particle tracking is utilized to reveal interactions, diffusion coefficients, active modes of driving motion, dynamic local structure, micromechanics, and microrheology. The basic analysis applied to those data is to determine the time-dependent mean-square displacement (MSD) of particle trajectories and perform time- and ensemble-averaging of similar motions. The motion of particles typically exhibits time-dependent power-law scaling, and only trajectories with qualitatively and quantitatively comparable MSD should be ensembled. Ensemble averaging trajectories that arise from different mechanisms, e.g., actively driven and diffusive, is incorrect and can result inaccurate correlations between structure, mechanics, and activity. We have developed an algorithm to automatically and accurately determine power-law scaling of experimentally measured single-particle MSD. Trajectories can then categorized and grouped according to user defined cutoffs of time, amplitudes, scaling exponent values, or combinations. Power-law fits are then provided for each trajectory alongside categorized groups of trajectories, histograms of power laws, and the ensemble-averaged MSD of each group. The codes are designed to be easily incorporated into existing user codes. We expect that this algorithm and program will be invaluable to anyone performing single-particle tracking, be it in physical or biophysical systems. Catalogue identifier: AEMD_v1_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/AEMD_v1_0.html Program obtainable from: CPC Program Library, Queen's University, Belfast, N. Ireland Licensing provisions: Standard CPC licence, http://cpc.cs.qub.ac.uk/licence/licence.html No. of lines in distributed program, including test data, etc.: 25 892 No. of bytes in distributed program, including test data, etc.: 5 572 780 Distribution format: tar.gz Programming language: MATLAB (MathWorks Inc.) version 7.11 (2010b) or higher, program should also be backwards compatible. Symbolic Math Toolboxes (5.5) is required. The Curve Fitting Toolbox (3.0) is recommended. Computer: Tested on Windows only, yet should work on any computer running MATLAB. In Windows 7, should be used as administrator, if the user is not the administrator the program may not be able to save outputs and temporary outputs to all locations. Operating system: Any supporting MATLAB (MathWorks Inc.) v7.11 / 2010b or higher. Supplementary material: Sample output files (approx. 30 MBytes) are available. Classification: 12 External routines: Several MATLAB subfunctions (m-files), freely available on the web, were used as part of and included in, this code: count, NaN suite, parseArgs, roundsd, subaxis, wcov, wmean, and the executable pdfTK.exe. Nature of problem: In many physical and biophysical areas employing single-particle tracking, having the time-dependent power-laws governing the time-averaged meansquare displacement (MSD) of a single particle is crucial. Those power laws determine the mode-of-motion and hint at the underlying mechanisms driving motion. Accurate determination of the power laws that describe each trajectory will allow categorization into groups for further analysis of single trajectories or ensemble analysis, e.g. ensemble and time-averaged MSD. Solution method: The algorithm in the provided program automatically analyzes and fits time-dependent power laws to single particle trajectories, then group particles according to user defined cutoffs. It accepts time-dependent trajectories of several particles, each trajectory is run through the program, its time-averaged MSD is calculated, and power laws are determined in regions where the MSD is linear on a log-log scale. Our algorithm searches for high-curvature points in experimental data, here time-dependent MSD. Those serve as anchor points for determining the ranges of the power-law fits. Power-law scaling is then accurately determined and error estimations of the parameters and quality of fit are provided. After all single trajectory time-averaged MSDs are fit, we obtain cutoffs from the user to categorize and segment the power laws into groups; cutoff are either in exponents of the power laws, time of appearance of the fits, or both together. The trajectories are sorted according to the cutoffs and the time- and ensemble-averaged MSD of each group is provided, with histograms of the distributions of the exponents in each group. The program then allows the user to generate new trajectory files with trajectories segmented according to the determined groups, for any further required analysis. Additional comments: README file giving the names and a brief description of all the files that make-up the package and clear instructions on the installation and execution of the program is included in the distribution package. Running time: On an i5 Windows 7 machine with 4 GB RAM the automated parts of the run (excluding data loading and user input) take less than 45 minutes to analyze and save all stages for an 844 trajectory file, including optional PDF save. Trajectory length did not affect run time (tested up to 3600 frames/trajectory), which was on average 3.2±0.4 seconds per trajectory.
NASA TLX: software for assessing subjective mental workload.
Cao, Alex; Chintamani, Keshav K; Pandya, Abhilash K; Ellis, R Darin
2009-02-01
The NASA Task Load Index (TLX) is a popular technique for measuring subjective mental workload. It relies on a multidimensional construct to derive an overall workload score based on a weighted average of ratings on six subscales: mental demand, physical demand, temporal demand, performance, effort, and frustration level. A program for implementing a computerized version of the NASA TLX is described. The software version assists in simplifying collection, postprocessing, and storage of raw data. The program collects raw data from the subject and calculates the weighted (or unweighted) workload score, which is output to a text file. The program can also be tailored to a specific experiment using a simple input text file, if desired. The program was designed in Visual Studio 2005 and is capable of running on a Pocket PC with Windows CE or on a PC with Windows 2000 or higher. The NASA TLX program is available for free download.
Khomtchouk, Bohdan B; Van Booven, Derek J; Wahlestedt, Claes
2014-01-01
The graphical visualization of gene expression data using heatmaps has become an integral component of modern-day medical research. Heatmaps are used extensively to plot quantitative differences in gene expression levels, such as those measured with RNAseq and microarray experiments, to provide qualitative large-scale views of the transcriptonomic landscape. Creating high-quality heatmaps is a computationally intensive task, often requiring considerable programming experience, particularly for customizing features to a specific dataset at hand. Software to create publication-quality heatmaps is developed with the R programming language, C++ programming language, and OpenGL application programming interface (API) to create industry-grade high performance graphics. We create a graphical user interface (GUI) software package called HeatmapGenerator for Windows OS and Mac OS X as an intuitive, user-friendly alternative to researchers with minimal prior coding experience to allow them to create publication-quality heatmaps using R graphics without sacrificing their desired level of customization. The simplicity of HeatmapGenerator is that it only requires the user to upload a preformatted input file and download the publicly available R software language, among a few other operating system-specific requirements. Advanced features such as color, text labels, scaling, legend construction, and even database storage can be easily customized with no prior programming knowledge. We provide an intuitive and user-friendly software package, HeatmapGenerator, to create high-quality, customizable heatmaps generated using the high-resolution color graphics capabilities of R. The software is available for Microsoft Windows and Apple Mac OS X. HeatmapGenerator is released under the GNU General Public License and publicly available at: http://sourceforge.net/projects/heatmapgenerator/. The Mac OS X direct download is available at: http://sourceforge.net/projects/heatmapgenerator/files/HeatmapGenerator_MAC_OSX.tar.gz/download. The Windows OS direct download is available at: http://sourceforge.net/projects/heatmapgenerator/files/HeatmapGenerator_WINDOWS.zip/download.
A Study of Gaps in Cyber Defense Automation
2016-10-13
converting all characters to lowercase. Next, the normalized file is tokenized using an n -length window. These n -tokens are then hashed into a Bloom filter...expensive and not readily available to most developers. However, with a complexity of O(N2), where N is the number of files (or the number of...prioritized by statistics that measure the impact of each feature on the website’s chances of becoming compromised, and the top N features are submitted to
Health Physics Code System for Evaluating Accidents Involving Radioactive Materials.
DOE Office of Scientific and Technical Information (OSTI.GOV)
2014-10-01
Version 03 The HOTSPOT Health Physics codes were created to provide Health Physics personnel with a fast, field-portable calculational tool for evaluating accidents involving radioactive materials. HOTSPOT codes provide a first-order approximation of the radiation effects associated with the atmospheric release of radioactive materials. The developer's website is: http://www.llnl.gov/nhi/hotspot/. Four general programs, PLUME, EXPLOSION, FIRE, and RESUSPENSION, calculate a downwind assessment following the release of radioactive material resulting from a continuous or puff release, explosive release, fuel fire, or an area contamination event. Additional programs deal specifically with the release of plutonium, uranium, and tritium to expedite an initial assessmentmore » of accidents involving nuclear weapons. The FIDLER program can calibrate radiation survey instruments for ground survey measurements and initial screening of personnel for possible plutonium uptake in the lung. The HOTSPOT codes are fast, portable, easy to use, and fully documented in electronic help files. HOTSPOT supports color high resolution monitors and printers for concentration plots and contours. The codes have been extensively used by the DOS community since 1985. Tables and graphical output can be directed to the computer screen, printer, or a disk file. The graphical output consists of dose and ground contamination as a function of plume centerline downwind distance, and radiation dose and ground contamination contours. Users have the option of displaying scenario text on the plots. HOTSPOT 3.0.1 fixes three significant Windows 7 issues: Executable installed properly under "Program Files/HotSpot 3.0". Installation package now smaller: removed dependency on older Windows DLL files which previously needed to; Forms now properly scale based on DPI instead of font for users who change their screen resolution to something other than 100%. This is a more common feature in Windows 7; Windows installer was starting everytime most users started the program, even after HotSpot was already installed. Now, after the program is installed the installer may come up once for each new user but only the first time they run HotSpot on a particular machine. So no user should see the installer come up more than once over many uses; and GPS capability updated to directly use a serial port through a USB connection. Non-USB connections should still work. Fixed table output inconsistencies for fire scenarios.« less
Windows Instant Messaging App Forensics: Facebook and Skype as Case Studies
Yang, Teing Yee; Dehghantanha, Ali; Choo, Kim-Kwang Raymond; Muda, Zaiton
2016-01-01
Instant messaging (IM) has changed the way people communicate with each other. However, the interactive and instant nature of these applications (apps) made them an attractive choice for malicious cyber activities such as phishing. The forensic examination of IM apps for modern Windows 8.1 (or later) has been largely unexplored, as the platform is relatively new. In this paper, we seek to determine the data remnants from the use of two popular Windows Store application software for instant messaging, namely Facebook and Skype on a Windows 8.1 client machine. This research contributes to an in-depth understanding of the types of terrestrial artefacts that are likely to remain after the use of instant messaging services and application software on a contemporary Windows operating system. Potential artefacts detected during the research include data relating to the installation or uninstallation of the instant messaging application software, log-in and log-off information, contact lists, conversations, and transferred files. PMID:26982207
Windows Instant Messaging App Forensics: Facebook and Skype as Case Studies.
Yang, Teing Yee; Dehghantanha, Ali; Choo, Kim-Kwang Raymond; Muda, Zaiton
2016-01-01
Instant messaging (IM) has changed the way people communicate with each other. However, the interactive and instant nature of these applications (apps) made them an attractive choice for malicious cyber activities such as phishing. The forensic examination of IM apps for modern Windows 8.1 (or later) has been largely unexplored, as the platform is relatively new. In this paper, we seek to determine the data remnants from the use of two popular Windows Store application software for instant messaging, namely Facebook and Skype on a Windows 8.1 client machine. This research contributes to an in-depth understanding of the types of terrestrial artefacts that are likely to remain after the use of instant messaging services and application software on a contemporary Windows operating system. Potential artefacts detected during the research include data relating to the installation or uninstallation of the instant messaging application software, log-in and log-off information, contact lists, conversations, and transferred files.
Windowed multipole for cross section Doppler broadening
NASA Astrophysics Data System (ADS)
Josey, C.; Ducru, P.; Forget, B.; Smith, K.
2016-02-01
This paper presents an in-depth analysis on the accuracy and performance of the windowed multipole Doppler broadening method. The basic theory behind cross section data is described, along with the basic multipole formalism followed by the approximations leading to windowed multipole method and the algorithm used to efficiently evaluate Doppler broadened cross sections. The method is tested by simulating the BEAVRS benchmark with a windowed multipole library composed of 70 nuclides. Accuracy of the method is demonstrated on a single assembly case where total neutron production rates and 238U capture rates compare within 0.1% to ACE format files at the same temperature. With regards to performance, clock cycle counts and cache misses were measured for single temperature ACE table lookup and for windowed multipole. The windowed multipole method was found to require 39.6% more clock cycles to evaluate, translating to a 7.9% performance loss overall. However, the algorithm has significantly better last-level cache performance, with 3 fewer misses per evaluation, or a 65% reduction in last-level misses. This is due to the small memory footprint of the windowed multipole method and better memory access pattern of the algorithm.
2011 Joint Service Power Expo. Volume 2. Video Files
2011-05-05
Untitled Document 2011power.html[3/22/2016 1:21:48 PM] Files are in Adobe, AVCHD Video (.m2ts), .avi format, MPEG-4 Movie (.mp4), and Windows Media...Development, ABSL Power Solutions Inc. 12799 - “Utilization of a Ducted Wind Turbine in a Trailer -Mounted Renewable Energy Micro-grid”, Mr. Mark Matthews, VP...of Sales and Marketing, WindTamer Corporation and Mr. Adeeb Saba WindTamer MPEG-4 Movie (.mp4) SESSION 16 On-Board Vehicle Power (OBVP) 1
WPC North American Surface Analyses
window and is a pdf file (requires Adobe Acrobat Reader to view). Create a Surface Analysis Loop North U.S. (South) Alaska Gulf of Alaska Color on White Black and White Display Loop Loop the sea-level
NASA Astrophysics Data System (ADS)
Gipson, John
2011-07-01
I describe the proposed data structure for storing, archiving and processing VLBI data. In this scheme, most VLBI data is stored in NetCDF files. NetCDF has the advantage that there are interfaces to most common computer languages including Fortran, Fortran-90, C, C++, Perl, etc, and the most common operating systems including linux, Windows and Mac. The data files for a particular session are organized by special ASCII "wrapper" files which contain pointers to the data files. This allows great flexibility in the processing and analysis of VLBI data, and also allows for extending the types of data used, e.g., source maps. I discuss the use of the new format in calc/solve and other VLBI analysis packages. I also discuss plans for transitioning to the new structure.
VizieR Online Data Catalog: MALT-45, a 7mm survey of the southern Galaxy (Jordan+, 2015)
NASA Astrophysics Data System (ADS)
Jordan, C. H.; Walsh, A. J.; Lowe, V.; Voronkov, M. A.; Ellingsen, S. P.; Breen, S. L.; Purcell, C. R.; Barnes, P. J.; Burton, M. G.; Cunningham, M. R.; Hill, T.; Jackson, J. M.; Longmore, S. N.; Peretto, N.; Urquhart, J. S.
2018-03-01
MALT-45 is an untargeted Galactic plane survey for spectral lines which are commonly bright in star-forming regions at 45GHz (7mm waveband). We have so far observed 5 square degrees within the region bounded by 330°<=l<=335°, b=+/-0.5°. MALT-45 observations were conducted on the Australia Telescope Compact Array (ATCA), which provides 2x2048MHz broad-band continuum windows for observing. Section 1.1 discusses the primary lines surveyed, and their rest frequencies dictate the positions of the broad-band windows for MALT-45. Within the frequency ranges of the broad-band windows, we survey for 12 spectral lines. (2 data files).
1982-11-12
File 1/0 Prgram Invocation Other Access M and Control Services KAPSE/Host Interface most Operating System Peripherals/ 01 su ?eetworks 6282318-2 Figure 3...3.2.4.3.8.5 Transitory Windows The TRANSITORY flag is used to prevent permanent dependence on temporary windows created simply for focusing on a part of the...KAPSE/Tool interfaces in terms of these low-level host-independent interfaces. In addition, the KAPSE/Host interface packages prevent the application
Optical Transient Monitor (OTM) for BOOTES Project
NASA Astrophysics Data System (ADS)
Páta, P.; Bernas, M.; Castro-Tirado, A. J.; Hudec, R.
2003-04-01
The Optical Transient Monitor (OTM) is a software for control of three wide and ultra-wide filed cameras of BOOTES (Burst Observer and Optical Transient Exploring System) station. The OTM is a PC based and it is powerful tool for taking images from two SBIG CCD cameras in same time or from one camera only. The control program for BOOTES cameras is Windows 98 or MSDOS based. Now the version for Windows 2000 is prepared. There are five main supported modes of work. The OTM program could control cameras and evaluate image data without human interaction.
Phast4Windows: A 3D graphical user interface for the reactive-transport simulator PHAST
Charlton, Scott R.; Parkhurst, David L.
2013-01-01
Phast4Windows is a Windows® program for developing and running groundwater-flow and reactive-transport models with the PHAST simulator. This graphical user interface allows definition of grid-independent spatial distributions of model properties—the porous media properties, the initial head and chemistry conditions, boundary conditions, and locations of wells, rivers, drains, and accounting zones—and other parameters necessary for a simulation. Spatial data can be defined without reference to a grid by drawing, by point-by-point definitions, or by importing files, including ArcInfo® shape and raster files. All definitions can be inspected, edited, deleted, moved, copied, and switched from hidden to visible through the data tree of the interface. Model features are visualized in the main panel of the interface, so that it is possible to zoom, pan, and rotate features in three dimensions (3D). PHAST simulates single phase, constant density, saturated groundwater flow under confined or unconfined conditions. Reactions among multiple solutes include mineral equilibria, cation exchange, surface complexation, solid solutions, and general kinetic reactions. The interface can be used to develop and run simple or complex models, and is ideal for use in the classroom, for analysis of laboratory column experiments, and for development of field-scale simulations of geochemical processes and contaminant transport.
Joseph Carpue's file drawer experiment - A murder mystery from 1801.
Freshwater, M Felix
2015-12-01
Today unpublished or "file drawer" experiments are the impetus for trial registration and reporting of all results. In 1801, Joseph Carpue, the father of modern plastic surgery, did a file drawer experiment for Benjamin West, who was President of the Royal Academy of Arts. George III had commissioned West to create the largest stained glass window ever created whose theme, the Crucifixion, was based upon Michelangelo's drawing. Subsequently, West suffered a series of political, professional and economic setbacks. In the summer of 1801, West's project was delayed. By the fall, West hoped that independent scientific confirmation of his design could salvage the project. West approached Carpue who obtained a murderer's fresh corpse that he crucified and documented the results with plaster casts created by sculptor Thomas Banks. Carpue's experiment showed that West's window design wrongly depicted the Crucifixion because West had posed the hands and shoulders incorrectly. West died in 1820 without ever being associated with Carpue's experiment. Carpue's obituary in The Lancet in 1846 contained Carpue's handwritten note that described the experiment but not West's Royal commission. As no records or publications associate the cast with West project, this can be considered to be a file drawer experiment. After 1801, West made further drawings of the Crucifixion that showed the figures in the same position as the cast. Nineteenth century auction catalogues suggest that West made a corrected Crucifixion painting, but its current location remains a mystery.
NASA Technical Reports Server (NTRS)
Luo, Victor; Khanampornpan, Teerapat; Boehmer, Rudy A.; Kim, Rachel Y.
2011-01-01
This software graphically displays all pertinent information from a Predicted Events File (PEF) using the Java Swing framework, which allows for multi-platform support. The PEF is hard to weed through when looking for specific information and it is a desire for the MRO (Mars Reconn aissance Orbiter) Mission Planning & Sequencing Team (MPST) to have a different way to visualize the data. This tool will provide the team with a visual way of reviewing and error-checking the sequence product. The front end of the tool contains much of the aesthetically appealing material for viewing. The time stamp is displayed in the top left corner, and highlighted details are displayed in the bottom left corner. The time bar stretches along the top of the window, and the rest of the space is allotted for blocks and step functions. A preferences window is used to control the layout of the sections along with the ability to choose color and size of the blocks. Double-clicking on a block will show information contained within the block. Zooming into a certain level will graphically display that information as an overlay on the block itself. Other functions include using hotkeys to navigate, an option to jump to a specific time, enabling a vertical line, and double-clicking to zoom in/out. The back end involves a configuration file that allows a more experienced user to pre-define the structure of a block, a single event, or a step function. The individual will have to determine what information is important within each block and what actually defines the beginning and end of a block. This gives the user much more flexibility in terms of what the tool is searching for. In addition to the configurability, all the settings in the preferences window are saved in the configuration file as well
Integrated Structural Analysis and Test Program
NASA Technical Reports Server (NTRS)
Kaufman, Daniel
2005-01-01
An integrated structural-analysis and structure-testing computer program is being developed in order to: Automate repetitive processes in testing and analysis; Accelerate pre-test analysis; Accelerate reporting of tests; Facilitate planning of tests; Improve execution of tests; Create a vibration, acoustics, and shock test database; and Integrate analysis and test data. The software package includes modules pertaining to sinusoidal and random vibration, shock and time replication, acoustics, base-driven modal survey, and mass properties and static/dynamic balance. The program is commanded by use of ActiveX controls. There is minimal need to generate command lines. Analysis or test files are selected by opening a Windows Explorer display. After selecting the desired input file, the program goes to a so-called analysis data process or test data process, depending on the type of input data. The status of the process is given by a Windows status bar, and when processing is complete, the data are reported in graphical, tubular, and matrix form.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Curcija, Dragan Charlie; Zhu, Ling; Czarnecki, Stephen
WINDOW features include: - Microsoft Windows TM interface - algorithms for the calculation of total fenestration product U-values and Solar Heat Gain Coefficient consistent with ASHRAE SPC 142, ISO 15099, and the National Fenestration Rating Council - a Condensation Resistance Index in accordance with the NFRC 500 Standard - and integrated database of properties - imports data from other LBNL window analysis software: - Import THERM file into the Frame Library - Import records from IGDB and OPtics5 into the Glass Library for the optical properties of coated and uncoated glazings, laminates, and applied films. Program Capabilities WINDOW 7.2 offersmore » the following features: The ability to analyze products made from any combination of glazing layers, gas layers, frames, spacers, and dividers under any environmental conditions and at any tilt; The ability to model complex glazing systems such as venetian blinds and roller shades. Directly accessible libraries of window system components, (glazing systems, glazing layers, gas fills, frame and divider elements), and environmental conditions; The choice of working in English (IP), or Systeme International (SI) units; The ability to specify the dimensions and thermal properties of each frame element (header, sills, jamb, mullion) in a window; A multi-band (wavelength-by-wavelength) spectral model; A Glass Library which can access spectral data files for many common glazing materials from the Optics5database; A night-sky radiative model; A link with the DOE-2.1E and Energy Plus building energy analysis program. Performance Indices and Other Results For a user-defined fenestration system and user-defined environmental conditions, WINDOW calculates: The U-value, solar heat gain coefficient, shading coefficient, and visible transmittance for the complete window system; The U-value, solar heat gain coefficient, shading coefficient, and visible transmittance for the glazing system (center-of-glass values); The U-values of the frame and divider elements and corresponding edge-of-glass areas (based on generic correlations); The total solar and visible transmittance and reflectances of the glazing system. Color properties, i.e. L*, a*, and b* color coordinates, dominant wavelength, and purity for transmitted and reflected (outdoor) solar radiation; The damage-weighted transmittance of the glazing system between 0.3 an 0.38 microns; The angular dependence of the solar and visible transmittances, solar and visible reflectances, solar absorptance, and solar heat gain coefficient of the glazing system; The percent relative humidity of the inside and outside air for which condensation will occur on the interior and exterior glazing surfaces respectively; The center-of-glass temperature distribution.« less
Progress on China nuclear data processing code system
NASA Astrophysics Data System (ADS)
Liu, Ping; Wu, Xiaofei; Ge, Zhigang; Li, Songyang; Wu, Haicheng; Wen, Lili; Wang, Wenming; Zhang, Huanyu
2017-09-01
China is developing the nuclear data processing code Ruler, which can be used for producing multi-group cross sections and related quantities from evaluated nuclear data in the ENDF format [1]. The Ruler includes modules for reconstructing cross sections in all energy range, generating Doppler-broadened cross sections for given temperature, producing effective self-shielded cross sections in unresolved energy range, calculating scattering cross sections in thermal energy range, generating group cross sections and matrices, preparing WIMS-D format data files for the reactor physics code WIMS-D [2]. Programming language of the Ruler is Fortran-90. The Ruler is tested for 32-bit computers with Windows-XP and Linux operating systems. The verification of Ruler has been performed by comparison with calculation results obtained by the NJOY99 [3] processing code. The validation of Ruler has been performed by using WIMSD5B code.
Detection with Enhanced Energy Windowing Phase I Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bass, David A.; Enders, Alexander L.
2016-12-01
This document reviews the progress of Phase I of the Detection with Enhanced Energy Windowing (DEEW) project. The DEEW project is the implementation of software incorporating an algorithm which reviews data generated by radiation portal monitors and utilizes advanced and novel techniques for detecting radiological and fissile material while not alarming on Naturally Occurring Radioactive Material. Independent testing indicated that the Enhanced Energy Windowing algorithm showed promise at reducing the probability of alarm in the stream of commerce compared to existing algorithms and other developmental algorithms, while still maintaining adequate sensitivity to threats. This document contains a brief description ofmore » the project, instructions for setting up and running the applications, and guidance to help make reviewing the output files and source code easier.« less
An Evaluation of TCP with Larger Initial Windows
NASA Technical Reports Server (NTRS)
Allman, Mark; Hayes, Christopher; Ostermann, Shawn
1998-01-01
Transmission Control Protocol (TCP's) slow start algorithm gradually increases the amount of data a sender injects into the network, which prevents the sender from overwhelming the network with an inappropriately large burst of traffic. However, the slow start algorithm can make poor use of the available band-width for transfers which are small compared to the bandwidth-delay product of the link, such as file transfers up to few thousand characters over satellite links or even transfers of several hundred bytes over local area networks. This paper evaluates a proposed performance enhancement that raises the initial window used by TCP from 1 MSS-sized segment to roughly 4 KB. The paper evaluates the impact of using larger initial windows on TCP transfers over both the shared Internet and dialup modem links.
Graphical User Interface for the NASA FLOPS Aircraft Performance and Sizing Code
NASA Technical Reports Server (NTRS)
Lavelle, Thomas M.; Curlett, Brian P.
1994-01-01
XFLOPS is an X-Windows/Motif graphical user interface for the aircraft performance and sizing code FLOPS. This new interface simplifies entering data and analyzing results, thereby reducing analysis time and errors. Data entry is simpler because input windows are used for each of the FLOPS namelists. These windows contain fields to input the variable's values along with help information describing the variable's function. Analyzing results is simpler because output data are displayed rapidly. This is accomplished in two ways. First, because the output file has been indexed, users can view particular sections with the click of a mouse button. Second, because menu picks have been created, users can plot engine and aircraft performance data. In addition, XFLOPS has a built-in help system and complete on-line documentation for FLOPS.
Unobtrusive Social Network Data From Email
2008-12-01
PERSON Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std Z39-18 outlook archived files and stores that data into an SQL - database. Communication...Applications ( VBA ) program was installed on the personal computers (PC) of all participants, in the session window of their Microsoft Outlook. Details of
Development of a DICOM library
NASA Astrophysics Data System (ADS)
Kim, Dongsun; Shin, Dongkyu M.; Kim, Dongyoun M.
2001-08-01
Object-oriented DICOM decoding library was developed as a type of DLL for MS-Windows environment development. It supports all DICOM standard Transfer Syntaxes, multi-frame images, RLE decoding and window level adjusting. Image library for medical application was also developed as a type of DLL and ActiveX Control using proposed DICOM library. It supports display of DICOM image, cine mode and basic manipulations. For an application of a proposed image library, a couple of DICOM viewers were developed. One can be used as an off-line DICOM Workstation, and the other can be used for browsing the local DICOM files.
Stimulation at Desert Peak -modeling with the coupled THM code FEHM
kelkar, sharad
2013-04-30
Numerical modeling of the 2011 shear stimulation at the Desert Peak well 27-15. This submission contains the FEHM executable code for a 64-bit PC Windows-7 machine, and the input and output files for the results presented in the included paper from ARMA-213 meeting.
SnagIt, Version 6.1 For Windows
Don C. Bragg
2002-01-01
As with most other professions, ecology has become increasingly dependent on information technology and on the ability to service journals, scientists, resource managers, and the taxpaying public with digital files. Ecologists who once devoted their careers to field experimentation now find themselves scrambling to organize web sites and multimedia presentations, or...
Real time programming environment for Windows, Appendix A
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1998-04-05
This appendix contains all source code for the RTProE system. The following file contents are included: pdb.h; hgen.l; hgen.y; igen.l; igen.y; pdm.l; pdm.y; rtdata.l; rtdata.y; framegen.c; librt.c; librt.h; rtsched.c; build.tsh; sde.tcl; rtsched.def.
Fundamental study of compression for movie files of coronary angiography
NASA Astrophysics Data System (ADS)
Ando, Takekazu; Tsuchiya, Yuichiro; Kodera, Yoshie
2005-04-01
When network distribution of movie files was considered as reference, it could be useful that the lossy compression movie files which has small file size. We chouse three kinds of coronary stricture movies with different moving speed as an examination object; heart rate of slow, normal and fast movies. The movies of MPEG-1, DivX5.11, WMV9 (Windows Media Video 9), and WMV9-VCM (Windows Media Video 9-Video Compression Manager) were made from three kinds of AVI format movies with different moving speeds. Five kinds of movies that are four kinds of compression movies and non-compression AVI instead of the DICOM format were evaluated by Thurstone's method. The Evaluation factors of movies were determined as "sharpness, granularity, contrast, and comprehensive evaluation." In the virtual bradycardia movie, AVI was the best evaluation at all evaluation factors except the granularity. In the virtual normal movie, an excellent compression technique is different in all evaluation factors. In the virtual tachycardia movie, MPEG-1 was the best evaluation at all evaluation factors expects the contrast. There is a good compression form depending on the speed of movies because of the difference of compression algorithm. It is thought that it is an influence by the difference of the compression between frames. The compression algorithm for movie has the compression between the frames and the intra-frame compression. As the compression algorithm give the different influence to image by each compression method, it is necessary to examine the relation of the compression algorithm and our results.
Profex: a graphical user interface for the Rietveld refinement program BGMN.
Doebelin, Nicola; Kleeberg, Reinhard
2015-10-01
Profex is a graphical user interface for the Rietveld refinement program BGMN . Its interface focuses on preserving BGMN 's powerful and flexible scripting features by giving direct access to BGMN input files. Very efficient workflows for single or batch refinements are achieved by managing refinement control files and structure files, by providing dialogues and shortcuts for many operations, by performing operations in the background, and by providing import filters for CIF and XML crystal structure files. Refinement results can be easily exported for further processing. State-of-the-art graphical export of diffraction patterns to pixel and vector graphics formats allows the creation of publication-quality graphs with minimum effort. Profex reads and converts a variety of proprietary raw data formats and is thus largely instrument independent. Profex and BGMN are available under an open-source license for Windows, Linux and OS X operating systems.
Profex: a graphical user interface for the Rietveld refinement program BGMN
Doebelin, Nicola; Kleeberg, Reinhard
2015-01-01
Profex is a graphical user interface for the Rietveld refinement program BGMN. Its interface focuses on preserving BGMN’s powerful and flexible scripting features by giving direct access to BGMN input files. Very efficient workflows for single or batch refinements are achieved by managing refinement control files and structure files, by providing dialogues and shortcuts for many operations, by performing operations in the background, and by providing import filters for CIF and XML crystal structure files. Refinement results can be easily exported for further processing. State-of-the-art graphical export of diffraction patterns to pixel and vector graphics formats allows the creation of publication-quality graphs with minimum effort. Profex reads and converts a variety of proprietary raw data formats and is thus largely instrument independent. Profex and BGMN are available under an open-source license for Windows, Linux and OS X operating systems. PMID:26500466
Phast4Windows: a 3D graphical user interface for the reactive-transport simulator PHAST.
Charlton, Scott R; Parkhurst, David L
2013-01-01
Phast4Windows is a Windows® program for developing and running groundwater-flow and reactive-transport models with the PHAST simulator. This graphical user interface allows definition of grid-independent spatial distributions of model properties-the porous media properties, the initial head and chemistry conditions, boundary conditions, and locations of wells, rivers, drains, and accounting zones-and other parameters necessary for a simulation. Spatial data can be defined without reference to a grid by drawing, by point-by-point definitions, or by importing files, including ArcInfo® shape and raster files. All definitions can be inspected, edited, deleted, moved, copied, and switched from hidden to visible through the data tree of the interface. Model features are visualized in the main panel of the interface, so that it is possible to zoom, pan, and rotate features in three dimensions (3D). PHAST simulates single phase, constant density, saturated groundwater flow under confined or unconfined conditions. Reactions among multiple solutes include mineral equilibria, cation exchange, surface complexation, solid solutions, and general kinetic reactions. The interface can be used to develop and run simple or complex models, and is ideal for use in the classroom, for analysis of laboratory column experiments, and for development of field-scale simulations of geochemical processes and contaminant transport. Published 2012. This article is a U.S. Government work and is in the public domain in the USA.
User Interactive Software for Analysis of Human Physiological Data
NASA Technical Reports Server (NTRS)
Cowings, Patricia S.; Toscano, William; Taylor, Bruce C.; Acharya, Soumydipta
2006-01-01
Ambulatory physiological monitoring has been used to study human health and performance in space and in a variety of Earth-based environments (e.g., military aircraft, armored vehicles, small groups in isolation, and patients). Large, multi-channel data files are typically recorded in these environments, and these files often require the removal of contaminated data prior to processing and analyses. Physiological data processing can now be performed with user-friendly, interactive software developed by the Ames Psychophysiology Research Laboratory. This software, which runs on a Windows platform, contains various signal-processing routines for both time- and frequency- domain data analyses (e.g., peak detection, differentiation and integration, digital filtering, adaptive thresholds, Fast Fourier Transform power spectrum, auto-correlation, etc.). Data acquired with any ambulatory monitoring system that provides text or binary file format are easily imported to the processing software. The application provides a graphical user interface where one can manually select and correct data artifacts utilizing linear and zero interpolation and adding trigger points for missed peaks. Block and moving average routines are also provided for data reduction. Processed data in numeric and graphic format can be exported to Excel. This software, PostProc (for post-processing) requires the Dadisp engineering spreadsheet (DSP Development Corp), or equivalent, for implementation. Specific processing routines were written for electrocardiography, electroencephalography, electromyography, blood pressure, skin conductance level, impedance cardiography (cardiac output, stroke volume, thoracic fluid volume), temperature, and respiration
VizieR Online Data Catalog: Sgr B2(N) and Sgr B2(M) IRAM 30m line survey (Belloche+, 2013)
NASA Astrophysics Data System (ADS)
Belloche, A.; Mueller, H. S. P.; Menten, K. M.; Schilke, P.; Comito, C.
2013-08-01
The list of line identifications corresponding to the blue labels in Figs. 2 to 7 where the labels are often too crowded to be easily readable are available in ASCII format. The lists are split into six files, three for Sgr B2(N) and three for Sgr B2(M). For each source, there is one file per atmospheric window (3, 2, and 1mm). Each file is ordered by increasing frequency. The observed and synthetic spectra of Sgr B2(N) and Sgr B2(M) between 80 and 116GHz are available both in ASCII and FITS formats. The synthetic spectra were resampled to the same frequency channels as the observed spectra. The blanking value is -1000K for the ASCII files. There is one ASCII file per source. There are two FITS files per source, one for the observed spectrum and one for the synthetic spectrum. The intensities are in main-beam temperature scale in K. The blanking value is 42.75234K for the observed spectrum of SgrB2(N) and 53.96533K for the observed spectrum of SgrB2(M). (9 data files).
Determination of the optimal tolerance for MLC positioning in sliding window and VMAT techniques
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hernandez, V., E-mail: vhernandezmasgrau@gmail.com; Abella, R.; Calvo, J. F.
2015-04-15
Purpose: Several authors have recommended a 2 mm tolerance for multileaf collimator (MLC) positioning in sliding window treatments. In volumetric modulated arc therapy (VMAT) treatments, however, the optimal tolerance for MLC positioning remains unknown. In this paper, the authors present the results of a multicenter study to determine the optimal tolerance for both techniques. Methods: The procedure used is based on dynalog file analysis. The study was carried out using seven Varian linear accelerators from five different centers. Dynalogs were collected from over 100 000 clinical treatments and in-house software was used to compute the number of tolerance faults as amore » function of the user-defined tolerance. Thus, the optimal value for this tolerance, defined as the lowest achievable value, was investigated. Results: Dynalog files accurately predict the number of tolerance faults as a function of the tolerance value, especially for low fault incidences. All MLCs behaved similarly and the Millennium120 and the HD120 models yielded comparable results. In sliding window techniques, the number of beams with an incidence of hold-offs >1% rapidly decreases for a tolerance of 1.5 mm. In VMAT techniques, the number of tolerance faults sharply drops for tolerances around 2 mm. For a tolerance of 2.5 mm, less than 0.1% of the VMAT arcs presented tolerance faults. Conclusions: Dynalog analysis provides a feasible method for investigating the optimal tolerance for MLC positioning in dynamic fields. In sliding window treatments, the tolerance of 2 mm was found to be adequate, although it can be reduced to 1.5 mm. In VMAT treatments, the typically used 5 mm tolerance is excessively high. Instead, a tolerance of 2.5 mm is recommended.« less
VizieR Online Data Catalog: ALMA survey of Lupus protoplanetary disks. I. (Ansdell+, 2016)
NASA Astrophysics Data System (ADS)
Ansdell, M.; Williams, J. P.; van der Marel, N.; Carpenter, J. M.; Guidi, G.; Hogerheijde, M.; Mathews, G. S.; Manara, C. F.; Miotello, A.; Natta, A.; Oliveira, I.; Tazzari, M.; Testi, L.; van Dishoeck, E. F.; van Terwisga, S. E.
2016-11-01
Our ALMA Cycle 2 observations (Project ID: 2013.1.00220.S) were obtained on 2015 June 14 (AGK-type sources and unknown spectral types) and 2015 June 15 (M-type sources). The continuum spectral windows were centered on 328.3, 340.0, and 341.8GHz with bandwidths of 1.875, 0.938, and 1.875 GHz and channel widths of 15.625, 0.244, and 0.977MHz, respectively. The bandwidth-weighted mean continuum frequency was 335.8GHz (890um). The spectral setup included two windows covering the 13CO and C18O 3-2 transitions; these spectral windows were centered on 330.6 and 329.3GHz, respectively, with bandwidths of 58.594MHz, channel widths of 0.122MHz, and velocity resolutions of 0.11km/s. (3 data files).
Pulse-Echo Ultrasonic Imaging Method for Eliminating Sample Thickness Variation Effects
NASA Technical Reports Server (NTRS)
Roth, Don J. (Inventor)
1997-01-01
A pulse-echo, immersion method for ultrasonic evaluation of a material which accounts for and eliminates nonlevelness in the equipment set-up and sample thickness variation effects employs a single transducer and automatic scanning and digital imaging to obtain an image of a property of the material, such as pore fraction. The nonlevelness and thickness variation effects are accounted for by pre-scan adjustments of the time window to insure that the echoes received at each scan point are gated in the center of the window. This information is input into the scan file so that, during the automatic scanning for the material evaluation, each received echo is centered in its time window. A cross-correlation function calculates the velocity at each scan point, which is then proportionalized to a color or grey scale and displayed on a video screen.
Window Design Strategies to Conserve Energy. NBS Building Science Series 104.
ERIC Educational Resources Information Center
Hastings, S. Robert; Crenshaw, Richard W.
A multitude of design strategies are available to achieve energy-efficient windows. Opportunities for improving window performance fall into six groups: site, exterior appendages, frame, glazing, interior accessories, and building interior. Design strategies within these groups can improve one or more of the six energy functions of windows: solar…
Chen, Keguang; Lyu, Huiying; Xie, Youzhou; Yang, Lin; Zhang, Tianyu; Dai, Peidong
2016-03-01
To investigate whether differences existing in the distance between facial nerve (FN) and round window niche opening among congenital aural atresia (CAA), congenital aural stenosis (CAS) and a normal control group and to assess its effect on the round window implantation of vibrant soundbridge, CT images of 10 normal subjects (20 ears), 27 CAS patients (30 ears) and 25 CAA patients (30 ears) were analyzed. The distances from the central point of round window niche opening to the terminal point of the horizontal segment, the salient point of pyramidal segment, the beginning point of the vertical segment, and the vertical segment of the facial nerve (abbreviate as OA, OB, OC, OE, respectively) were calculated based on three-dimensional reconstruction using mimics software. The results suggested that the pyramidal segment of the FN was positioned more closely to round window niche opening in patients with both CAA and CAS groups than that in control group, whereas there was no significant difference between CAA and CAS group (P < 0.05). The vertical portion of the FN was positioned more closely to round window niche opening in the CAA group than those in both the CAS and control groups with statistical significance (P < 0.05). Furthermore, the vertical portion of the FN was positioned more closely to round window niche opening in the CAS group than that in control group (P < 0.05). In conclusion, the dislocation between facial nerve and round window niche in patients with congenital auditory canal malformations could have significant effects on the round window implantation of vibrant soundbridge. Moreover, three-dimensional measurements and assessments before surgery might be helpful for a safer surgical approach and implantation of vibrant soundbridge.
Shahi, Shahriar; Rahimi, Saeed; Shiezadeh, Vahab; Ashasi, Habib; Abdolrahimi, Majid; Foroughreyhani, Mohammad
2012-01-01
Aim: The aim of the present study was to electrochemically evaluate corrosion resistance of RaCe and Mtwo files after repeated sterilization and preparation procedures. Study Design: A total of 450 rotary files were used. In the working groups, 72 files from each file type were distributed into 4 groups. RaCe and Mtwo files were used to prepare one root canal of the mesial root of extracted human mandibular first molars. The procedure was repeated to prepare 2 to 8 canals. The following irrigation solutions were used: group 1, RaCe files with 2.5% NaOCl; group 2, RaCe files with normal saline; group 3, Mtwo files with 2.5% NaOCl; and group 4, Mtwo files with normal saline in the manner described. In autoclave groups, 72 files from each file type were evenly distributed into 2 groups. Files were used for a cycle of sterilization without the use of files for root canal preparation. Nine new unused files from each file type were used as controls. Then the instruments were sent for corrosion assessment. Mann-Whitney U and Wilcoxon tests were used for independent and dependent groups, respectively. Results: Statistical analysis indicated that there were significant differences in corrosion resistance of files associated with working and autoclave groups between RaCe and Mtwo file types (p<0.001). Conclusions: Corrosion resistance of #25, #30, and #35 Mtwo files is significantly higher than that in RaCe files with similar sizes. Key words:Corrosion, NiTi instruments, autoclave, RaCe, Mtwo. PMID:22143690
Nokleberg, Warren J.; Badarch, Gombosuren; Berzin, Nikolai A.; Diggles, Michael F.; Hwang, Duk-Hwan; Khanchuk, Alexander I.; Miller, Robert J.; Naumova, Vera V.; Obolensky, Alexander A.; Ogasawara, Masatsugu; Parfenov, Leonid M.; Prokopiev, Andrei V.; Rodionov, Sergey M.; Yan, Hongquan
2004-01-01
This is the online version of a CD-ROM publication. It contains all of the data that are on the disc but extra files have been removed: index files, software installers, and Windows autolaunch files. This publication contains a a series of files for Northeast Asia geodynamics, mineral deposit location, and metallogenic belt maps descriptions of map units and metallogenic belts, and stratigraphic columns. This region includes Eastern Siberia, Russian Far East, Mongolia, Northeast China, South Korea, and Japan. The files include: (1) a geodynamics map at a scale of 1:5,000,000; (2) page-size stratigraphic columns for major terranes; (3) a generalized geodynamics map at a scale of 1:15,000,000; (4) a mineral deposit location map at a scale of 1:7,500,000; (5) metallogenic belt maps at a scale of 1:15,000,000; (6) detailed descriptions of geologic units with references; (7) detailed descriptions of metallogenic belts with references; and (8) summary mineral deposit and metallogenic belt tables. The purpose of this publication is to provide high-quality, digital graphic files for maps and figures, and Word files for explanations, descriptions, and references to customers and users.
Bhattacharya, Anindya; De, Rajat K
2010-08-01
Distance based clustering algorithms can group genes that show similar expression values under multiple experimental conditions. They are unable to identify a group of genes that have similar pattern of variation in their expression values. Previously we developed an algorithm called divisive correlation clustering algorithm (DCCA) to tackle this situation, which is based on the concept of correlation clustering. But this algorithm may also fail for certain cases. In order to overcome these situations, we propose a new clustering algorithm, called average correlation clustering algorithm (ACCA), which is able to produce better clustering solution than that produced by some others. ACCA is able to find groups of genes having more common transcription factors and similar pattern of variation in their expression values. Moreover, ACCA is more efficient than DCCA with respect to the time of execution. Like DCCA, we use the concept of correlation clustering concept introduced by Bansal et al. ACCA uses the correlation matrix in such a way that all genes in a cluster have the highest average correlation values with the genes in that cluster. We have applied ACCA and some well-known conventional methods including DCCA to two artificial and nine gene expression datasets, and compared the performance of the algorithms. The clustering results of ACCA are found to be more significantly relevant to the biological annotations than those of the other methods. Analysis of the results show the superiority of ACCA over some others in determining a group of genes having more common transcription factors and with similar pattern of variation in their expression profiles. Availability of the software: The software has been developed using C and Visual Basic languages, and can be executed on the Microsoft Windows platforms. The software may be downloaded as a zip file from http://www.isical.ac.in/~rajat. Then it needs to be installed. Two word files (included in the zip file) need to be consulted before installation and execution of the software. Copyright 2010 Elsevier Inc. All rights reserved.
BamTools: a C++ API and toolkit for analyzing and managing BAM files.
Barnett, Derek W; Garrison, Erik K; Quinlan, Aaron R; Strömberg, Michael P; Marth, Gabor T
2011-06-15
Analysis of genomic sequencing data requires efficient, easy-to-use access to alignment results and flexible data management tools (e.g. filtering, merging, sorting, etc.). However, the enormous amount of data produced by current sequencing technologies is typically stored in compressed, binary formats that are not easily handled by the text-based parsers commonly used in bioinformatics research. We introduce a software suite for programmers and end users that facilitates research analysis and data management using BAM files. BamTools provides both the first C++ API publicly available for BAM file support as well as a command-line toolkit. BamTools was written in C++, and is supported on Linux, Mac OSX and MS Windows. Source code and documentation are freely available at http://github.org/pezmaster31/bamtools.
Magnesium Object Manager Sandbox, A More Effective Sandbox Method for Windows 7
2012-03-01
keys, synchronization primitives , etc.). The object body is specific to, and the same for, each object type; it contains information common to each...the Object Directory Specific Rights Synchronization Object (Event, Mutex, Semaphore , Timer) Synchronization objects allow multiple threads to... Synchronization Object Specific Rights . . . . . . . . . . . . . . . . . . . . . 19 2.5 File Object Specific Rights
The NIST Step Class Library (Step Into the Future)
1990-09-01
Figure 6. Excerpt from a STEP exclange file based on the Geometry model 1be NIST STEP Class Libary Page 13 An issue of concern in this...Scheifler, R., Gettys, J., and Newman, P., X Window System: C Library and Protocol Reference. Digital Press, Bedford, Mass, 1988. [Schenck90] Schenck, D
Diary of a Conversion--Lotus 1-2-3 to Symphony 1.1.
ERIC Educational Resources Information Center
Dunnewin, Larry
1986-01-01
Describes the uses of Lotus 1-2-3 (a spreadsheet-graphics-database program created by Lotus Development Corporation) and Symphony 1.1 (a refinement and expansion of Symphony 1.01 providing memory efficiency, speed, ease of use, greater file compatibility). Spreadsheet and graphics capabilities, the use of windows, database environment, and…
58. RSS Windows Editors: First Impressions
ERIC Educational Resources Information Center
Swettenham, Steve
2006-01-01
An RSS feed is a list of topics made available from a webpage via a standard XML file format known as RSS, an abbreviation of either Really Simple Syndication or Rich Site Summary (Wikipedia, 2006). The end-user subscribes to their favorite Internet content site via RSS-aware software. Once subscribed, announcements with appropriate links are…
BOREAS AFM-2 King Air 1994 Aircraft Flux and Moving Window Data
NASA Technical Reports Server (NTRS)
Kelly, Robert D.; Hall, Forrest G. (Editor); Newcomer, Jeffrey A. (Editor); Smith, David E. (Technical Monitor)
2000-01-01
The BOREAS AFM-2 team collected pass-by-pass fluxes (and many other statistics) for a large number of level (constant altitude), straight-line passes used in a variety of flight patterns. The data were collected by the University of Wyoming King Air in 1994 BOREAS IFCs 1-3. Most of these data were collected at 60-70 m above ground level, but a significant number of passes were also flown at various levels in the planetary boundary layer, up to about the inversion height. This documentation concerns only the data from the straight and level passes that are presented as original (over the NSA and SSA) and moving window values (over the Transect). Another archive of King Air data is also available, containing data from all the soundings flown by the King Air 1994 IFCs 1-3. The data are stored in tabular ASCII files. The data files are available on a CD-ROM (see document number 20010000884) or from the Oak Ridge National Laboratory (ORNL) Distributed Active Archive Center (DAAC).
VizieR Online Data Catalog: Interferometric CO obs. of 126 CALIFA galaxies (Bolatto+, 2017)
NASA Astrophysics Data System (ADS)
Bolatto, A. D.; Wong, T.; Utomo, D.; Blitz, L.; Vogel, S. N.; Sanchez, S. F.; Barrera-Ballesteros, J.; Cao, Y.; Colombo, D.; Dannerbauer, H.; Garcia-Benito, R.; Herrera-Camus, R.; Husemann, B.; Kalinova, V.; Leroy, A. K.; Leung, G.; Levy, R. C.; Mast, D.; Ostriker, E.; Rosolowsky, E.; Sandstrom, K. M.; Teuben, P.; van de Ven, G.; Walter, F.
2018-05-01
Observations of the original 177 CALIFA galaxies sample were conducted by CARMA's E-array in late 2014, integrating 40 minutes per galaxy. 125 galaxies were subsequently (from 2014 December to 2015 March) observed in the more extended D configuration, with an additional ~3.5hr of integration per target. The CARMA correlator was configured with five 250MHz windows covering the 12CO line with 3.4km/s resolution and a 3000km/s velocity range, and three 500MHz windows covering the 13CO line with 14.3km/s resolution and a 3800km/s velocity range. (3 data files).
Sandia Advanced MEMS Design Tools, Version 2.2.5
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yarberry, Victor; Allen, James; Lantz, Jeffery
2010-01-19
The Sandia National Laboratories Advanced MEMS Design Tools, Version 2.2.5, is a collection of menus, prototype drawings, and executables that provide significant productivity enhancements when using AutoCAD to design MEMS components. This release is designed for AutoCAD 2000i, 2002, or 2004 and is supported under Windows NT 4.0, Windows 2000, or XP. SUMMiT V (Sandia Ultra planar Multi level MEMS Technology) is a 5 level surface micromachine fabrication technology, which customers internal and external to Sandia can access to fabricate prototype MEMS devices. This CD contains an integrated set of electronic files that: a) Describe the SUMMiT V fabrication processmore » b) Facilitate the process of designing MEMS with the SUMMiT process (prototype file, Design Rule Checker, Standard Parts Library) New features in this version: AutoCAD 2004 support has been added. SafeExplode ? a new feature that explodes blocks without affecting polylines (avoids exploding polylines into objects that are ignored by the DRC and Visualization tools). Layer control menu ? a pull-down menu for selecting layers to isolate, freeze, or thaw. Updated tools: A check has been added to catch invalid block names. DRC features: Added username/password validation, added a method to update the user?s password. SNL_DRC_WIDTH ? a value to control the width of the DRC error lines. SNL_BIAS_VALUE ? a value use to offset selected geometry SNL_PROCESS_NAME ? a value to specify the process name Documentation changes: The documentation has been updated to include the new features. While there exist some files on the CD that are used in conjunction with software package AutoCAD, these files are not intended for use independent of the CD. Note that the customer must purchase his/her own copy of AutoCAD to use with these files.« less
Troise Rioda, W.; Nervetti, A.
2001-01-01
The well known complexity to collect the clinical data of patients and in particular in the area of rheumatology push us to develop a computerized clinical chart in order to facilitate the classification, evaluation and monitoring of these patients. The proposed computerized clinical chart is easy to use but at the same time is a very potent tool that allow the clinicians to organize the classic rheumatological pathologies as well as the more complexes or even rare. The proposed clinical chart is based on a relational database (FileMaker Pro 5.0v1) available for both the actual operative systems implemented on personal computers (Windows and Macintosh); this allow the full compatibility among the two systems, the possibility of exchanging data without any loss of information. The computerized clinical chart is structured on modules for specific pathologies and for homogeneous groups of illnesses. Basically the modules are defined correlated files of data for a specific pathology but that can be used also as a common pool for different pathologies. Our experience, based on ten years of use, indicates in the computerized rheumatological clinical chart an indispensable tool for rheumatologists with a real friendly use.
Updated System-Availability and Resource-Allocation Program
NASA Technical Reports Server (NTRS)
Viterna, Larry
2004-01-01
A second version of the Availability, Cost and Resource Allocation (ACARA) computer program has become available. The first version was reported in an earlier tech brief. To recapitulate: ACARA analyzes the availability, mean-time-between-failures of components, life-cycle costs, and scheduling of resources of a complex system of equipment. ACARA uses a statistical Monte Carlo method to simulate the failure and repair of components while complying with user-specified constraints on spare parts and resources. ACARA evaluates the performance of the system on the basis of a mathematical model developed from a block-diagram representation. The previous version utilized the MS-DOS operating system and could not be run by use of the most recent versions of the Windows operating system. The current version incorporates the algorithms of the previous version but is compatible with Windows and utilizes menus and a file-management approach typical of Windows-based software.
Pulse-echo ultrasonic imaging method for eliminating sample thickness variation effects
NASA Technical Reports Server (NTRS)
Roth, Don J. (Inventor)
1995-01-01
A pulse-echo, immersion method for ultrasonic evaluation of a material is discussed. It accounts for and eliminates nonlevelness in the equipment set-up and sample thickness variation effects employs a single transducer, automatic scanning and digital imaging to obtain an image of a property of the material, such as pore fraction. The nonlevelness and thickness variation effects are accounted for by pre-scan adjusments of the time window to insure that the echoes received at each scan point are gated in the center of the window. This information is input into the scan file so that, during the automatic scanning for the material evaluation, each received echo is centered in its time window. A cross-correlation function calculates the velocity at each scan point, which is then proportionalized to a color or grey scale and displayed on a video screen.
Commander Young removes CAP from FDF stowage locker on middeck
NASA Technical Reports Server (NTRS)
1981-01-01
Commander Young removes Crew Activity Plans (CAP) from Flight Data File (FD/FDF) modular stowage locker single tray assembly located in forward middeck locker MF28E. Window shade and filter kit on port side bulkhead and potable water tank on middeck floor appear in view. Photo was taken by Pilot Crippen with a 35mm camera.
43. Historic photo of Bruce Lundin posing in front of ...
43. Historic photo of Bruce Lundin posing in front of observation window in exhaust cone at base of test stand A in Building 202, September 1960. On file at NASA Plumbrook Research Center, Sandusky, Ohio. NASA photo number C-53170. - Rocket Engine Testing Facility, GRC Building No. 202, NASA Glenn Research Center, Cleveland, Cuyahoga County, OH
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-21
...] through Web CRD [System], by a Member immediately following the date of termination, but in no event later...) above, in the event that the Member learns of facts or circumstances causing any information set forth... through a window or by video monitor. The individual responsible for proctoring at each administration...
FRAN: financial ratio analysis and more (Version 2.0 for Windows)
Bruce G. Hansen; Arnold J., Jr. Palmer
1999-01-01
FRAN is a computer-based, stand-alone program designed to generate important financial and operating ratios from tax and wage forms filed with the Internal Revenue Service. FRAN generates standard profitability, financial/leverage, liquidity/solvency, and activity ratios, as well as unique measures of workforce and capital cost and acquisition. Information produced by...
Pilot Fullerton reviews FDF and TAGS printout on forward flight deck
NASA Technical Reports Server (NTRS)
1982-01-01
Pilot Fullerton, wearing communications kit assembly (ASSY) mini headset (HDST), reviews flight data file (FDF) checklist and text and graphics system (TAGS) printout (ticker tape) while in pilots ejection seat (S2). Pilot Station control panels F4, F7, F8, O3, window shade, and portable oxygen system (POS) assy appear in view.
NLEdit: A generic graphical user interface for Fortran programs
NASA Technical Reports Server (NTRS)
Curlett, Brian P.
1994-01-01
NLEdit is a generic graphical user interface for the preprocessing of Fortran namelist input files. The interface consists of a menu system, a message window, a help system, and data entry forms. A form is generated for each namelist. The form has an input field for each namelist variable along with a one-line description of that variable. Detailed help information, default values, and minimum and maximum allowable values can all be displayed via menu picks. Inputs are processed through a scientific calculator program that allows complex equations to be used instead of simple numeric inputs. A custom user interface is generated simply by entering information about the namelist input variables into an ASCII file. There is no need to learn a new graphics system or programming language. NLEdit can be used as a stand-alone program or as part of a larger graphical user interface. Although NLEdit is intended for files using namelist format, it can be easily modified to handle other file formats.
"Broken windows" and the risk of gonorrhea.
Cohen, D; Spear, S; Scribner, R; Kissinger, P; Mason, K; Wildgen, J
2000-01-01
OBJECTIVES: We examined the relationships between neighborhood conditions and gonorrhea. METHODS: We assessed 55 block groups by rating housing and street conditions. We mapped all cases of gonorrhea between 1994 and 1996 and calculated aggregated case rates by block group. We obtained public school inspection reports and assigned findings to the block groups served by the neighborhood schools. A "broken windows" index measured housing quality, abandoned cars, graffiti, trash, and public school deterioration. Using data from the 1990 census and 1995 updates, we determined the association between "broken windows," demographic characteristics, and gonorrhea rates. RESULTS: The broken windows index explained more of the variance in gonorrhea rates than did a poverty index measuring income, unemployment, and low education. In high-poverty neighborhoods, block groups with high broken windows scores had significantly higher gonorrhea rates than block groups with low broken windows scores (46.6 per 1000 vs 25.8 per 1000; P < .001). CONCLUSIONS: The robust association of deteriorated physical conditions of local neighborhoods with gonorrhea rates, independent of poverty, merits an intervention trial to test whether the environment has a causal role in influencing high-risk sexual behaviors. PMID:10667184
BamTools: a C++ API and toolkit for analyzing and managing BAM files
Barnett, Derek W.; Garrison, Erik K.; Quinlan, Aaron R.; Strömberg, Michael P.; Marth, Gabor T.
2011-01-01
Motivation: Analysis of genomic sequencing data requires efficient, easy-to-use access to alignment results and flexible data management tools (e.g. filtering, merging, sorting, etc.). However, the enormous amount of data produced by current sequencing technologies is typically stored in compressed, binary formats that are not easily handled by the text-based parsers commonly used in bioinformatics research. Results: We introduce a software suite for programmers and end users that facilitates research analysis and data management using BAM files. BamTools provides both the first C++ API publicly available for BAM file support as well as a command-line toolkit. Availability: BamTools was written in C++, and is supported on Linux, Mac OSX and MS Windows. Source code and documentation are freely available at http://github.org/pezmaster31/bamtools. Contact: barnetde@bc.edu PMID:21493652
BioVEC: a program for biomolecule visualization with ellipsoidal coarse-graining.
Abrahamsson, Erik; Plotkin, Steven S
2009-09-01
Biomolecule Visualization with Ellipsoidal Coarse-graining (BioVEC) is a tool for visualizing molecular dynamics simulation data while allowing coarse-grained residues to be rendered as ellipsoids. BioVEC reads in configuration files, which may be output from molecular dynamics simulations that include orientation output in either quaternion or ANISOU format, and can render frames of the trajectory in several common image formats for subsequent concatenation into a movie file. The BioVEC program is written in C++, uses the OpenGL API for rendering, and is open source. It is lightweight, allows for user-defined settings for and texture, and runs on either Windows or Linux platforms.
Li, Qinglin; Zhao, Meng; Wang, Xiaodan
2018-01-01
To compare the differences between the Kidney Disease Improving Global Outcomes (KDIGO) criteria of the 48-hour window and the 7-day window in the diagnosis of acute kidney injury (AKI) in very elderly patients, as well as the relationship between the 48-hour and 7-day windows for diagnosis and 90-day mortality. We retrospectively enrolled very elderly patients (≥75 years old) from the geriatrics department of the Chinese PLA General Hospital between January 2007 and December 2015. AKI patients were divided into 48-hour and 7-day groups by their diagnosis criteria. AKI patients were divided into survivor and nonsurvivor groups by their outcomes within 90 days after diagnosis of AKI. In total, 652 patients were included in the final analysis. The median age of the cohort was 87 (84-91) years, the majority (623, 95.6%) of whom were male. Of the 652 AKI patients, 334 cases (51.2%) were diagnosed with AKI by the 48-hour window for diagnosis, while 318 cases (48.8%) were by the 7-day window for diagnosis. The 90-day mortality was 42.5% in patients with 48-hour window AKI and 24.2% in patients with 7-day window AKI. Kaplan-Meier curves showed that 90-day mortality was lower in the 7-day window AKI group than in the 48-hour window AKI group (log rank: P <0.001). Multivariate analysis by the Cox model revealed that 48-hour window for diagnosis hazard ratio (HR=1.818; 95% CI: 1.256-2.631; P =0.002) was associated with higher 90-day mortality. The 90-day mortality was higher in 48-hour window AKI than in 7-day window AKI in very elderly patients. The 48-hour KDIGO window definition may be less sensitive. The 48-hour KDIGO window definition is significantly better correlated with subsequent mortality and is, therefore, still appropriate for clinical use. Finding early, sensitive biomarkers of kidney damage is a future direction of research.
Musale, P K; Mujawar, S A V
2014-04-01
This in vitro study aimed to evaluate the efficacy of rotary ProFile, ProTaper, Hero Shaper and K-files in shaping ability, cleaning efficacy, preparation time and instrument distortion in primary molars. Sixty extracted primary mandibular second molars were divided into four equal groups: Group I K-file, Group II ProFile, Group III ProTaper file and Group IV Hero Shaper file. The shaping ability was determined by comparing pre- and post-instrumentation CBCT scans and data analysed with SPSS program using the Chi-square test. Cleaning efficacy was evaluated by the degree of India ink removal from the canal walls under stereomicroscopy. Instrumentation times were calculated for each tooth and instrument distortion was visually checked and duly noted. The cleaning efficacy and instrumentation time were determined using ANOVA with Tukey's correction. Instrument distortion was analysed using Chi-square test. The canal taper was significantly more conical for rotary files as compared to K-files with Chi-square test (p < 0.05). Cleaning efficacy of rotary files with average scores (Groups II- 0.68, III- 0.48 and IV- 0.58) was significantly better than K-files (Group I- 0.93) (p < 0.05). Mean instrumentation time with K-file (20.7 min) was significantly higher than rotary files (Groups II 8.9, III 5.6, and IV 8.1 min) (p < 0.05). Instrument distortion was observed in Group I (4.3%), while none of the rotary files were distorted. Rotary files prepared more conical canals in primary teeth than manual instruments. Reduced preparation time with rotary files enhances patient cooperation especially in young children.
GoPhast: a graphical user interface for PHAST
Winston, Richard B.
2006-01-01
GoPhast is a graphical user interface (GUI) for the USGS model PHAST. PHAST simulates multicomponent, reactive solute transport in three-dimensional, saturated, ground-water flow systems. PHAST can model both equilibrium and kinetic geochemical reactions. PHAST is derived from HST3D (flow and transport) and PHREEQC (geochemical calculations). The flow and transport calculations are restricted to constant fluid density and constant temperature. The complexity of the input required by PHAST makes manual construction of its input files tedious and error-prone. GoPhast streamlines the creation of the input file and helps reduce errors. GoPhast allows the user to define the spatial input for the PHAST flow and transport data file by drawing points, lines, or polygons on top, front, and side views of the model domain. These objects can have up to two associated formulas that define their extent perpendicular to the view plane, allowing the objects to be three-dimensional. Formulas are also used to specify the values of spatial data (data sets) both globally and for individual objects. Objects can be used to specify the values of data sets independent of the spatial and temporal discretization of the model. Thus, the grid and simulation periods for the model can be changed without respecifying spatial data pertaining to the hydrogeologic framework and boundary conditions. This report describes the operation of GoPhast and demonstrates its use with examples. GoPhast runs on Windows 2000, Windows XP, and Linux operating systems.
Apple Macintosh programs for nucleic and protein sequence analyses.
Bellon, B
1988-01-01
This paper describes a package of programs for handling and analyzing nucleic acid and protein sequences using the Apple Macintosh microcomputer. There are three important features of these programs: first, because of the now classical Macintosh interface the programs can be easily used by persons with little or no computer experience. Second, it is possible to save all the data, written in an editable scrolling text window or drawn in a graphic window, as files that can be directly used either as word processing documents or as picture documents. Third, sequences can be easily exchanged with any other computer. The package is composed of thirteen programs, written in Pascal programming language. PMID:2832832
Overview of GSE as a multifunctional GUI
NASA Astrophysics Data System (ADS)
Kurtovich, Boyan; Malangone, Fabio; Voss, David L.; Carssow, Douglas B.; Fritz, Theodore A.; Mavretic, Anton
2009-08-01
Ground Support Equipment (GSE) [1] is a versatile and multifunctional graphical user interface (GUI) and a software/hardware platform. It is a custom-designed system executed in the LabVIEW programming language to serve as an instrument health monitor for the Loss Cone Imager (LCI) satellite project. GSE mimics the behavior of the onboard Experiment Computer System (ECS). Its functions comprise the measurement of voltage, current, and power, as well as acting as a safety mechanism in case of any anomalous condition (e.g., over-current and/or over-voltage situation). Individual log files record the sessions during which data is gathered and analyzed. Safety/warning alarm flags shall be 'visible' from any individual window/tab. Analog-to-Digital Conversion (ADC) particle group measurements will be displayed on six individual panels. GSE will be supplemented with a comprehensive user's manual for added clarity.
NASA Astrophysics Data System (ADS)
Verkaik, J.
2013-12-01
The Netherlands Hydrological Instrument (NHI) model predicts water demands in periods of drought, supporting the Dutch decision makers in taking operational as well as long-term decisions with respect to the water supply. Other applications of NHI are predicting fresh-salt interaction, nutrient loadings, and agriculture change. The NHI model consists of several coupled models: a saturated groundwater model (MODFLOW), an unsaturated groundwater model (MetaSWAP), a sub-catchment surface water model (MOZART), and a distribution network of surface waters model (DM/SOBEK). Each of these models requires specific, usually large, input data that may be the result of sophisticated schematization workflows. Input data can also be dependent on each other, for example, the precipitation data is input for the unsaturated zone model (cells) as well as for the surface water models (polygons). For efficient data management, we developed several Python tools such that the modeler or stakeholder can use the model in a user-friendly manner, and data is managed in a consistent, transparent and reproducible way. Two open source Python tools are presented here: the data version control module for the workflow manager VisTrails called FileSync, and the NHI model control script that uses FileSync. VisTrails is an open-source scientific workflow and provenance management system that provides support for simulations, data exploration and visualization. Since VisTrails does not directly support version control we developed a version control module called FileSync. With this generic module, the user can synchronize data from and to his workflow through a dialog window. The FileSync dialog calls the FileSync script that is command-line based and performs the actual data synchronization. This script allows the user to easily create a model repository, upload and download data, create releases and define scenarios. The data synchronization approach applied here differs from systems as Subversion or Git, since these systems do not perform well for large (binary) model data files. For this reason, a new concept of parameterization and data splitting has been implemented. Each file, or set of files, is uniquely labeled as a parameter, and for this parameter metadata is maintained by Subversion. The metadata data contains file hashes to identify data content and the location where the actual bulk data are stored that can be reached by FTP. The NHI model control script is a command-line driven Python script for pre-processing, running, and post-processing the NHI model and uses one single configuration file for all computational kernels. This configuration file is an easy-to-use, keyword-driven, Windows INI-file, having separate sections for all the kernels. It also includes a FileSync data section where the user can specify version controlled model data to be used as input. The NHI control script keeps all the data consistent during the pre-processing. Furthermore, this script is able to do model state handling when the NHI model is used for ensemble forecasting.
Ozgul, Betul Memis; Orhan, Kaan; Oz, Firdevs Tulga
2015-09-01
We investigated inhibition of lesion progression in artificial enamel lesions. Lesions were created on primary and permanent anterior teeth (n = 10 each) and were divided randomly into two groups with two windows: Group 1 (window A: resin infiltration; window B: negative control) and Group 2 (window A: resin infiltration + fluoride varnish; window B: fluoride varnish). After pH cycling, micro-computed tomography was used to analyze progression of lesion depth and changes in mineral density. Resin infiltration and resin infiltration + fluoride varnish significantly inhibited progression of lesion depth in primary teeth (P < 0.05). Inhibition of lesion depth progression in permanent teeth was significantly greater after treatment with resin infiltration + fluoride varnish than in the negative control (P < 0.05). Change in mineral density was smaller in the resin infiltration and resin infiltration + fluoride varnish groups; however, the difference was not significant for either group (P > 0.05). Resin infiltration is a promising method of inhibiting progression of caries lesions.
1992-04-01
megabytes greater than required to store the operating system and X-Windows. * CD-ROM Player. Standard CD-ROM player using ISO 9660 file format...CAVGERRO 235 .4596 . 8583 .0000 4.0000 42 CAVGFOUN 235 3.9362 .3700 .0000 4.0000 43 SlIT 235 172.3106 207.4205 .0000 1039.0000 44 S2T 235 122.0638
Banerjee, Shyamashree; Gupta, Parth Sarthi Sen; Nayek, Arnab; Das, Sunit; Sur, Vishma Pratap; Seth, Pratyay; Islam, Rifat Nawaz Ul; Bandyopadhyay, Amal K
2015-01-01
Automated genome sequencing procedure is enriching the sequence database very fast. To achieve a balance between the entry of sequences in the database and their analyses, efficient software is required. In this end PHYSICO2, compare to earlier PHYSICO and other public domain tools, is most efficient in that it i] extracts physicochemical, window-dependent and homologousposition-based-substitution (PWS) properties including positional and BLOCK-specific diversity and conservation, ii] provides users with optional-flexibility in setting relevant input-parameters, iii] helps users to prepare BLOCK-FASTA-file by the use of Automated Block Preparation Tool of the program, iv] performs fast, accurate and user-friendly analyses and v] redirects itemized outputs in excel format along with detailed methodology. The program package contains documentation describing application of methods. Overall the program acts as efficient PWS-analyzer and finds application in sequence-bioinformatics. PHYSICO2: is freely available at http://sourceforge.net/projects/physico2/ along with its documentation at https://sourceforge.net/projects/physico2/files/Documentation.pdf/download for all users.
Banerjee, Shyamashree; Gupta, Parth Sarthi Sen; Nayek, Arnab; Das, Sunit; Sur, Vishma Pratap; Seth, Pratyay; Islam, Rifat Nawaz Ul; Bandyopadhyay, Amal K
2015-01-01
Automated genome sequencing procedure is enriching the sequence database very fast. To achieve a balance between the entry of sequences in the database and their analyses, efficient software is required. In this end PHYSICO2, compare to earlier PHYSICO and other public domain tools, is most efficient in that it i] extracts physicochemical, window-dependent and homologousposition-based-substitution (PWS) properties including positional and BLOCK-specific diversity and conservation, ii] provides users with optional-flexibility in setting relevant input-parameters, iii] helps users to prepare BLOCK-FASTA-file by the use of Automated Block Preparation Tool of the program, iv] performs fast, accurate and user-friendly analyses and v] redirects itemized outputs in excel format along with detailed methodology. The program package contains documentation describing application of methods. Overall the program acts as efficient PWS-analyzer and finds application in sequence-bioinformatics. Availability PHYSICO2: is freely available at http://sourceforge.net/projects/physico2/ along with its documentation at https://sourceforge.net/projects/physico2/files/Documentation.pdf/download for all users. PMID:26339154
Chen, Keguang; Yin, Dongming; Lyu, Huiying; Yang, Lin; Zhang, Tianyu; Dai, Peidong
2016-01-01
With the aggravation of the external auditory canal malformation, the size of extra-niche fossa became smaller, providing concrete data and valuable information for the better design, selecting and safer implantation of the transducer in the area of round window niche. Three-dimensional measurements and assessments before surgery might be helpful for a safer surgical approach and implantation of a vibrant soundbridge. The aim of this study was to investigate whether differences exist in the morphology of the posterior tympanum related to the round window vibroplasty among congenital aural atresia (CAA), congenital aural stenosis (CAS), and a normal control group, and to analyze its effect on the round window implantation of vibrant soundbridge. CT images of 10 normal subjects (20 ears), 27 CAS patients (30 ears), and 25 CAA patients (30 ears) were analyzed. The depth and the size of outside fossa of round window niche related to the round window vibroplasty (extra-niche fossa)and the distances between the center of round window niche and extra-niche fossa were calculated based on three-dimensional reconstruction using mimics software. Finally, the data were analyzed statistically. The size of extra-niche fossa in the atresia group was smaller than in the stenosis group (p < 0.05); furthermore, the size of extra-niche fossa in the stenosis group was smaller than that of the control group (p < 0.05). There was no statistically significant difference of the depth of extra-niche fossa among different groups.
Seismic Canvas: Evolution as a Data Exploration and Analysis Tool
NASA Astrophysics Data System (ADS)
Kroeger, G. C.
2015-12-01
SeismicCanvas, originally developed as a prototype interactive waveform display and printing application for educational use has evolved to include significant data exploration and analysis functionality. The most recent version supports data import from a variety of standard file formats including SAC and mini-SEED, as well as search and download capabilities via IRIS/FDSN Web Services. Data processing tools now include removal of means and trends, interactive windowing, filtering, smoothing, tapering, resampling. Waveforms can be displayed in a free-form canvas or as a record section based on angular or great circle distance, azimuth or back azimuth. Integrated tau-p code allows the calculation and display of theoretical phase arrivals from a variety of radial Earth models. Waveforms can be aligned by absolute time, event time, picked or theoretical arrival times and can be stacked after alignment. Interactive measurements include means, amplitudes, time delays, ray parameters and apparent velocities. Interactive picking of an arbitrary list of seismic phases is supported. Bode plots of amplitude and phase spectra and spectrograms can be created from multiple seismograms or selected windows of seismograms. Direct printing is implemented on all supported platforms along with output of high-resolution pdf files. With these added capabilities, the application is now being used as a data exploration tool for research. Coded in C++ and using the cross-platform Qt framework, the most recent version is available as a 64-bit application for Windows 7-10, Mac OS X 10.6-10.11, and most distributions of Linux, and a 32-bit version for Windows XP and 7. With the latest improvements and refactoring of trace display classes, the 64-bit versions have been tested with over 250 million samples and remain responsive in interactive operations. The source code is available under a LPGLv3 license and both source and executables are available through the IRIS SeisCode repository.
Kasam, Swetha; Mariswamy, Annapoorna Ballagere
2016-06-01
Although success of endodontic therapy has significantly improved in the last few decades due to the introduction of novel materials and techniques, failures of endodontic therapy requiring re-treatment still comprise a significant percentage of patients requiring root canal treatment. To evaluate and compare the effective removal of gutta percha and sealer, amount of apical debris extrusion and time required for gutta percha removal using various endodontic files. Total 48 extracted mandibular premolars were mounted on acrylic blocks and endodontic procedure was carried out using size 40 K file and obturated using guttapercha and zinc oxide eugenol sealer. After one month storage, samples were decoronated, mounted on screw capped vials and subjected to removal of obturated material by four instruments: H files, safe sided H files, protaper universal retreatment rotary system and ultrasonic retreatment tip, grouped as 1, 2, 3, and 4 respectively. Only 2mm of obturated material from the coronal part was removed using no. 3 Gates Glidden drill, guttapercha was softened with a drop of xylene for 2 mins for each canal and retreatment was performed. The retreatment procedure was said to be complete when no visible debris were observed on the instrument flutes. The samples split into two halves and examined under stereomicroscope, photographed, assessed using AUTOCAD software and percentage of remaining filling material in coronal, middle, apical thirds of the canal was calculated in mm(2). Retreatment time was recorded in seconds and apically extruded debris was assessed by microbalance in grams for each tooth. The data was analyzed by using descriptive statistics, ANOVA and Scheffe's post hoc test through SPSS for windows (v 16.0). The ultrasonic retreatment tip had less percentage of residual guttapercha/sealer, shorter mean operating time and little apical extrusion with a significant difference (p<0.05) between the other groups. All techniques retained guttapercha/sealer remnants within the root canal. The ultrasonic retreatment tip proved to be an efficient method of removing obturated material. It was fastest with least apical debris extrusion.
Mariswamy, Annapoorna Ballagere
2016-01-01
Introduction Although success of endodontic therapy has significantly improved in the last few decades due to the introduction of novel materials and techniques, failures of endodontic therapy requiring re-treatment still comprise a significant percentage of patients requiring root canal treatment. Aim To evaluate and compare the effective removal of gutta percha and sealer, amount of apical debris extrusion and time required for gutta percha removal using various endodontic files. Materials and Methods Total 48 extracted mandibular premolars were mounted on acrylic blocks and endodontic procedure was carried out using size 40 K file and obturated using guttapercha and zinc oxide eugenol sealer. After one month storage, samples were decoronated, mounted on screw capped vials and subjected to removal of obturated material by four instruments: H files, safe sided H files, protaper universal retreatment rotary system and ultrasonic retreatment tip, grouped as 1, 2, 3, and 4 respectively. Only 2mm of obturated material from the coronal part was removed using no. 3 Gates Glidden drill, guttapercha was softened with a drop of xylene for 2 mins for each canal and retreatment was performed. The retreatment procedure was said to be complete when no visible debris were observed on the instrument flutes. The samples split into two halves and examined under stereomicroscope, photographed, assessed using AUTOCAD software and percentage of remaining filling material in coronal, middle, apical thirds of the canal was calculated in mm2. Retreatment time was recorded in seconds and apically extruded debris was assessed by microbalance in grams for each tooth. The data was analyzed by using descriptive statistics, ANOVA and Scheffe’s post hoc test through SPSS for windows (v 16.0). Results The ultrasonic retreatment tip had less percentage of residual guttapercha/sealer, shorter mean operating time and little apical extrusion with a significant difference (p<0.05) between the other groups. Conclusion All techniques retained guttapercha/sealer remnants within the root canal. The ultrasonic retreatment tip proved to be an efficient method of removing obturated material. It was fastest with least apical debris extrusion. PMID:27504397
NASA Astrophysics Data System (ADS)
Buxbaum, T. M.; Warnick, W. K.; Polly, B.; Hueffer, L. J.; Behr, S. A.
2006-12-01
The ARCUS Internet Media Archive (IMA) is a collection of photos, graphics, videos, and presentations about the Arctic that are shared through the Internet. It provides the arctic research community and the public at large with a centralized location where images and video pertaining to polar research can be browsed and retrieved for a variety of uses. The IMA currently contains almost 5,000 publicly accessible photos, including 3,000 photos from the National Science Foundation funded Teachers and Researchers Exploring and Collaborating (TREC) program, an educational research experience in which K-12 teachers participate in arctic research as a pathway to improving science education. The IMA also includes 360 video files, 260 audio files, and approximately 8,000 additional resources that are being prepared for public access. The contents of this archive are organized by file type, contributor's name, event, or by organization, with each photo or file accompanied by information on content, contributor source, and usage requirements. All the files are keyworded and all information, including file name and description, is completely searchable. ARCUS plans to continue to improve and expand the IMA with a particular focus on providing graphics depicting key arctic research results and findings as well as edited video archives of relevant scientific community meetings.
WORM - WINDOWED OBSERVATION OF RELATIVE MOTION
NASA Technical Reports Server (NTRS)
Bauer, F.
1994-01-01
The Windowed Observation of Relative Motion, WORM, program is primarily intended for the generation of simple X-Y plots from data created by other programs. It allows the user to label, zoom, and change the scale of various plots. Three dimensional contour and line plots are provided, although with more limited capabilities. The input data can be in binary or ASCII format, although all data must be in the same format. A great deal of control over the details of the plot is provided, such as gridding, size of tick marks, colors, log/semilog capability, time tagging, and multiple and phase plane plots. Many color and monochrome graphics terminals and hard copy printer/plotters are supported. The WORM executive commands, menu selections and macro files can be used to develop plots and tabular data, query the WORM Help library, retrieve data from input files, and invoke VAX DCL commands. WORM generated plots are displayed on local graphics terminals and can be copied using standard hard copy capabilities. Some of the graphics features of WORM include: zooming and dezooming various portions of the plot; plot documentation including curve labeling and function listing; multiple curves on the same plot; windowing of multiple plots and insets of the same plot; displaying a specific on a curve; and spinning the curve left, right, up, and down. WORM is written in PASCAL for interactive execution and has been implemented on a DEC VAX computer operating under VMS 4.7 with a virtual memory requirement of approximately 392K of 8 bit bytes. It uses the QPLOT device independent graphics library included with WORM. It was developed in 1988.
jsNMR: an embedded platform-independent NMR spectrum viewer.
Vosegaard, Thomas
2015-04-01
jsNMR is a lightweight NMR spectrum viewer written in JavaScript/HyperText Markup Language (HTML), which provides a cross-platform spectrum visualizer that runs on all computer architectures including mobile devices. Experimental (and simulated) datasets are easily opened in jsNMR by (i) drag and drop on a jsNMR browser window, (ii) by preparing a jsNMR file from the jsNMR web site, or (iii) by mailing the raw data to the jsNMR web portal. jsNMR embeds the original data in the HTML file, so a jsNMR file is a self-transforming dataset that may be exported to various formats, e.g. comma-separated values. The main applications of jsNMR are to provide easy access to NMR data without the need for dedicated software installed and to provide the possibility to visualize NMR spectra on web sites. Copyright © 2015 John Wiley & Sons, Ltd.
Ganguli, Sayak; Gupta, Manoj Kumar; Basu, Protip; Banik, Rahul; Singh, Pankaj Kumar; Vishal, Vineet; Bera, Abhisek Ranjan; Chakraborty, Hirak Jyoti; Das, Sasti Gopal
2014-01-01
With the advent of age of big data and advances in high throughput technology accessing data has become one of the most important step in the entire knowledge discovery process. Most users are not able to decipher the query result that is obtained when non specific keywords or a combination of keywords are used. Intelligent access to sequence and structure databases (IASSD) is a desktop application for windows operating system. It is written in Java and utilizes the web service description language (wsdl) files and Jar files of E-utilities of various databases such as National Centre for Biotechnology Information (NCBI) and Protein Data Bank (PDB). Apart from that IASSD allows the user to view protein structure using a JMOL application which supports conditional editing. The Jar file is freely available through e-mail from the corresponding author.
External-Compression Supersonic Inlet Design Code
NASA Technical Reports Server (NTRS)
Slater, John W.
2011-01-01
A computer code named SUPIN has been developed to perform aerodynamic design and analysis of external-compression, supersonic inlets. The baseline set of inlets include axisymmetric pitot, two-dimensional single-duct, axisymmetric outward-turning, and two-dimensional bifurcated-duct inlets. The aerodynamic methods are based on low-fidelity analytical and numerical procedures. The geometric methods are based on planar geometry elements. SUPIN has three modes of operation: 1) generate the inlet geometry from a explicit set of geometry information, 2) size and design the inlet geometry and analyze the aerodynamic performance, and 3) compute the aerodynamic performance of a specified inlet geometry. The aerodynamic performance quantities includes inlet flow rates, total pressure recovery, and drag. The geometry output from SUPIN includes inlet dimensions, cross-sectional areas, coordinates of planar profiles, and surface grids suitable for input to grid generators for analysis by computational fluid dynamics (CFD) methods. The input data file for SUPIN and the output file from SUPIN are text (ASCII) files. The surface grid files are output as formatted Plot3D or stereolithography (STL) files. SUPIN executes in batch mode and is available as a Microsoft Windows executable and Fortran95 source code with a makefile for Linux.
Distributing File-Based Data to Remote Sites Within the BABAR Collaboration
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gowdy, Stephen J.
BABAR [1] uses two formats for its data: Objectivity database and root [2] files. This poster concerns the distribution of the latter--for Objectivity data see [3]. The BABAR analysis data is stored in root files--one per physics run and analysis selection channel--maintained in a large directory tree. Currently BABAR has more than 4.5 TBytes in 200,000 root files. This data is (mostly) produced at SLAC, but is required for analysis at universities and research centers throughout the us and Europe. Two basic problems confront us when we seek to import bulk data from slac to an institute's local storage viamore » the network. We must determine which files must be imported (depending on the local site requirements and which files have already been imported), and we must make the optimum use of the network when transferring the data. Basic ftp-like tools (ftp, scp, etc) do not attempt to solve the first problem. More sophisticated tools like rsync [4], the widely-used mirror/synchronization program, compare local and remote file systems, checking for changes (based on file date, size and, if desired, an elaborate checksum) in order to only copy new or modified files. However rsync allows for only limited file selection. Also when, as in BABAR, an extremely large directory structure must be scanned, rsync can take several hours just to determine which files need to be copied. Although rsync (and scp) provides on-the-fly compression, it does not allow us to optimize the network transfer by using multiple streams, adjusting the tcp window size, or separating encrypted authentication from unencrypted data channels.« less
NetpathXL - An Excel Interface to the Program NETPATH
Parkhurst, David L.; Charlton, Scott R.
2008-01-01
NetpathXL is a revised version of NETPATH that runs under Windows? operating systems. NETPATH is a computer program that uses inverse geochemical modeling techniques to calculate net geochemical reactions that can account for changes in water composition between initial and final evolutionary waters in hydrologic systems. The inverse models also can account for the isotopic composition of waters and can be used to estimate radiocarbon ages of dissolved carbon in ground water. NETPATH relies on an auxiliary, database program, DB, to enter the chemical analyses and to perform speciation calculations that define total concentrations of elements, charge balance, and redox state of aqueous solutions that are then used in inverse modeling. Instead of DB, NetpathXL relies on Microsoft Excel? to enter the chemical analyses. The speciation calculation formerly included in DB is implemented within the program NetpathXL. A program DBXL can be used to translate files from the old DB format (.lon files) to NetpathXL spreadsheets, or to create new NetpathXL spreadsheets. Once users have a NetpathXL spreadsheet with the proper format, new spreadsheets can be generated by copying or saving NetpathXL spreadsheets. In addition, DBXL can convert NetpathXL spreadsheets to PHREEQC input files. New capabilities in PHREEQC (version 2.15) allow solution compositions to be written to a .lon file, and inverse models developed in PHREEQC to be written as NetpathXL .pat and model files. NetpathXL can open NetpathXL spreadsheets, NETPATH-format path files (.pat files), and NetpathXL-format path files (.pat files). Once the speciation calculations have been performed on a spreadsheet file or a .pat file has been opened, the NetpathXL calculation engine is identical to the original NETPATH. Development of models and viewing results in NetpathXL rely on keyboard entry as in NETPATH.
Aydin, Ugur; Karataslioglu, Emrah
2017-01-01
Canal transportation is a common sequel caused by rotary instruments. The purpose of the present study is to evaluate the degree of transportation after the use of Reciproc single-file instruments with or without glide path files. Thirty resin blocks with L-shaped canals were divided into three groups ( n = 10). Group 1 - canals were prepared with Reciproc-25 file. Group 2 - glide path file-G1 was used before Reciproc. Group 3 - glide path files-G1 and G2 were used before Reciproc. Pre- and post-instrumentation images were superimposed under microscope, and resin removed from the inner and outer surfaces of the root canal was calculated throughout 10 points. Statistical analysis was performed with Kruskal-Wallis test and post hoc Dunn test. For coronal and middle one-thirds, there was no significant difference among groups ( P > 0.05). For apical section, transportation of Group 1 was significantly higher than other groups ( P < 0.05). Using glide path files before Reciproc single-file system reduced the degree of apical canal transportation.
A land-surface Testbed for EOSDIS
NASA Technical Reports Server (NTRS)
Emery, William; Kelley, Tim
1994-01-01
The main objective of the Testbed project was to deliver satellite images via the Internet to scientific and educational users free of charge. The main method of operations was to store satellite images on a low cost tape library system, visually browse the raw satellite data, access the raw data filed, navigate the imagery through 'C' programming and X-Windows interface software, and deliver the finished image to the end user over the Internet by means of file transfer protocol methods. The conclusion is that the distribution of satellite imagery by means of the Internet is feasible, and the archiving of large data sets can be accomplished with low cost storage systems allowing multiple users.
Gross, Arnd; Ziepert, Marita; Scholz, Markus
2012-01-01
Analysis of clinical studies often necessitates multiple graphical representations of the results. Many professional software packages are available for this purpose. Most packages are either only commercially available or hard to use especially if one aims to generate or customize a huge number of similar graphical outputs. We developed a new, freely available software tool called KMWin (Kaplan-Meier for Windows) facilitating Kaplan-Meier survival time analysis. KMWin is based on the statistical software environment R and provides an easy to use graphical interface. Survival time data can be supplied as SPSS (sav), SAS export (xpt) or text file (dat), which is also a common export format of other applications such as Excel. Figures can directly be exported in any graphical file format supported by R. On the basis of a working example, we demonstrate how to use KMWin and present its main functions. We show how to control the interface, customize the graphical output, and analyse survival time data. A number of comparisons are performed between KMWin and SPSS regarding graphical output, statistical output, data management and development. Although the general functionality of SPSS is larger, KMWin comprises a number of features useful for survival time analysis in clinical trials and other applications. These are for example number of cases and number of cases under risk within the figure or provision of a queue system for repetitive analyses of updated data sets. Moreover, major adjustments of graphical settings can be performed easily on a single window. We conclude that our tool is well suited and convenient for repetitive analyses of survival time data. It can be used by non-statisticians and provides often used functions as well as functions which are not supplied by standard software packages. The software is routinely applied in several clinical study groups.
Gross, Arnd; Ziepert, Marita; Scholz, Markus
2012-01-01
Background Analysis of clinical studies often necessitates multiple graphical representations of the results. Many professional software packages are available for this purpose. Most packages are either only commercially available or hard to use especially if one aims to generate or customize a huge number of similar graphical outputs. We developed a new, freely available software tool called KMWin (Kaplan-Meier for Windows) facilitating Kaplan-Meier survival time analysis. KMWin is based on the statistical software environment R and provides an easy to use graphical interface. Survival time data can be supplied as SPSS (sav), SAS export (xpt) or text file (dat), which is also a common export format of other applications such as Excel. Figures can directly be exported in any graphical file format supported by R. Results On the basis of a working example, we demonstrate how to use KMWin and present its main functions. We show how to control the interface, customize the graphical output, and analyse survival time data. A number of comparisons are performed between KMWin and SPSS regarding graphical output, statistical output, data management and development. Although the general functionality of SPSS is larger, KMWin comprises a number of features useful for survival time analysis in clinical trials and other applications. These are for example number of cases and number of cases under risk within the figure or provision of a queue system for repetitive analyses of updated data sets. Moreover, major adjustments of graphical settings can be performed easily on a single window. Conclusions We conclude that our tool is well suited and convenient for repetitive analyses of survival time data. It can be used by non-statisticians and provides often used functions as well as functions which are not supplied by standard software packages. The software is routinely applied in several clinical study groups. PMID:22723912
Hosein, Riad B M; Mehta, Chetan; Stickley, John; Mcguirk, Simon P; Jones, Timothy J; Brawn, William J; Barron, David J
2007-11-01
A small sub-group of patients with hypoplastic left heart syndrome (HLHS) have normal-sized ascending aorta and arch. An alternative to the Norwood I procedure in these patients is the creation of an aorto-pulmonary (AP) window with a distal pulmonary artery band (PAB). We reviewed our experience with this technique and compared outcomes to the Norwood procedure for HLHS. All patients treated for HLHS in a single institution between 1992 and 2005 were analysed. This identified 13 patients treated with AP window and PAB compared to 333 patients undergoing stage I Norwood procedure. An unrestrictive AP window was created and the main PA was banded. Patient records and echocardiograms were analysed. Median follow-up was 10 (IQR 0-655) days and 100% complete. There were seven early deaths (54%) in the AP window group and two conversions to Norwood circulation. This was a significantly worse outcome than for the Norwood procedure over the same period, which had an early mortality of 29% (p=0.03). Kaplan-Meier actuarial analysis demonstrated a continued survival benefit of the Norwood group at 6 months (p=0.0005). Deaths were due to either low cardiac output syndrome (n=4) or sudden unheralded arrest (n=3). This occurred despite aortic cross-clamp and circulatory arrest times being significantly lower in the AP window group compared to the Norwood group (35+/-27 vs 55+/-16 min, p<0.01 and 16+/-29 vs 55+/-20 min, p<0.01, respectively). No differences in arterial saturations or systolic blood pressure existed between the groups, but diastolic blood pressure was significantly lower in the AP window group at 27+/-10 mmHg compared to 42+/-8 mmHg in the Norwood group (p=0.01) with evidence of flow reversal in the descending aorta. Differences in diastolic blood pressure between groups were abolished after conversion to stage II. Despite favourable anatomy and shorter ischaemic times, the AP window/PAB technique has a poor outcome compared to the Norwood procedure for HLHS. Low diastolic blood pressure with reversal of descending aortic flow in diastole was a feature of the AP window/PAB circulation. We recommend the Norwood procedure for these sub-types. This may have implications for newer 'hybrid' procedures for HLHS which create a similar palliative circulation.
PIV/HPIV Film Analysis Software Package
NASA Technical Reports Server (NTRS)
Blackshire, James L.
1997-01-01
A PIV/HPIV film analysis software system was developed that calculates the 2-dimensional spatial autocorrelations of subregions of Particle Image Velocimetry (PIV) or Holographic Particle Image Velocimetry (HPIV) film recordings. The software controls three hardware subsystems including (1) a Kodak Megaplus 1.4 camera and EPIX 4MEG framegrabber subsystem, (2) an IEEE/Unidex 11 precision motion control subsystem, and (3) an Alacron I860 array processor subsystem. The software runs on an IBM PC/AT host computer running either the Microsoft Windows 3.1 or Windows 95 operating system. It is capable of processing five PIV or HPIV displacement vectors per second, and is completely automated with the exception of user input to a configuration file prior to analysis execution for update of various system parameters.
Xie, Li-Hong; Tang, Jie; Miao, Wen-Jie; Tang, Xiang-Long; Li, Heng; Tang, An-Zhou
2018-06-01
We evaluated the risk of cochlear implantation through the round window membrane in the facial recess through a preoperative analysis of the angle between the facial nerve-round window and the cranial midline using high-resolution temporal bone CT. Temporal bone CT films of 176 patients with profound sensorineural hearing loss at our hospital from 2013 to 2015 were reviewed. The preoperative temporal bone CT scans of the patients were retrospectively analysed. The vertical distance (d value) from the leading edge of the facial nerve to the posterior wall of the external auditory canal and the angle (α value) between the line from the leading edge of the facial nerve to the midpoint of the round window membrane and the median sagittal line on the round window membrane plane were measured. Based on intraoperative observation, the round window membrane was divided into complete round window membrane exposure (group A), partial exposure (group B), and unexposed (group C) groups, and statistical analysis was performed. The α value could be effectively measured for all 176 patients (62.60 ± 7.12), and the d value could be effectively measured for 95 cases (5.53 ± 1.00). An analysis of the correlation between the α and d values of these 95 cases found a negative correlation. Of the 176 cases, one-way analysis of variance (ANOVA) showed that the differences among the groups were significant [P = 0.000 (< 0.05)]. The angle (α value) between the line connecting the leading edge of the facial nerve to the midpoint of the round window and the median sagittal line measured in preoperative CT scans was associated with the difficulty of intraoperatively exposing the round window membrane. When the α value was larger than a certain degree, the difficulty of exposing the round window membrane was increased. In such cases, the surgeon should fully expose the round window membrane during surgery, which could result decrease the likelihood of complications.
Platform for Postprocessing Waveform-Based NDE
NASA Technical Reports Server (NTRS)
Roth, Don
2008-01-01
Taking advantage of the similarities that exist among all waveform-based non-destructive evaluation (NDE) methods, a common software platform has been developed containing multiple- signal and image-processing techniques for waveforms and images. The NASA NDE Signal and Image Processing software has been developed using the latest versions of LabVIEW, and its associated Advanced Signal Processing and Vision Toolkits. The software is useable on a PC with Windows XP and Windows Vista. The software has been designed with a commercial grade interface in which two main windows, Waveform Window and Image Window, are displayed if the user chooses a waveform file to display. Within these two main windows, most actions are chosen through logically conceived run-time menus. The Waveform Window has plots for both the raw time-domain waves and their frequency- domain transformations (fast Fourier transform and power spectral density). The Image Window shows the C-scan image formed from information of the time-domain waveform (such as peak amplitude) or its frequency-domain transformation at each scan location. The user also has the ability to open an image, or series of images, or a simple set of X-Y paired data set in text format. Each of the Waveform and Image Windows contains menus from which to perform many user actions. An option exists to use raw waves obtained directly from scan, or waves after deconvolution if system wave response is provided. Two types of deconvolution, time-based subtraction or inverse-filter, can be performed to arrive at a deconvolved wave set. Additionally, the menu on the Waveform Window allows preprocessing of waveforms prior to image formation, scaling and display of waveforms, formation of different types of images (including non-standard types such as velocity), gating of portions of waves prior to image formation, and several other miscellaneous and specialized operations. The menu available on the Image Window allows many further image processing and analysis operations, some of which are found in commercially-available image-processing software programs (such as Adobe Photoshop), and some that are not (removing outliers, Bscan information, region-of-interest analysis, line profiles, and precision feature measurements).
ERIC Educational Resources Information Center
National Center for Education Statistics (ED), Washington, DC.
This CD-ROM contains a separate electronic codebook for each of the following National Center for Education Statistics data sets: (1) B94, Baccalaureate and Beyond 1993-94 (restricted); (2) B97, Baccalaureate and Beyond 1993-97 (restricted); (3) BP4, Beginning Postsecondary Students 1990-94 (restricted); (4) FAC, 1992-93 National Student of…
2015-06-01
National Instruments. The National Instruments DAQ is a full-featured PC running Windows 7. The DAQ, electromagnetic transmitter , and batteries for the... electromagnetic induction Environet Environet, Inc. ESTCP Environmental Security Technology Certification Program ftp file transfer protocol FUDS formerly used...capabilities of a currently available advanced electromagnetic induction sensor developed specifically for discrimination on real sites under operational
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-02
... Holder firm. Each FBW user has an FBW Login ID. The Exchange proposes to charge a Requesting TPH $100 per Login ID per month. There will be a cap of $2,000 per month for any Requesting TPH. Therefore, any TPH that requests access to the FBW Market Access Controls Window for more than 20 login IDs will not be...
CO2calc: A User-Friendly Seawater Carbon Calculator for Windows, Mac OS X, and iOS (iPhone)
Robbins, L.L.; Hansen, M.E.; Kleypas, J.A.; Meylan, S.C.
2010-01-01
A user-friendly, stand-alone application for the calculation of carbonate system parameters was developed by the U.S. Geological Survey Florida Shelf Ecosystems Response to Climate Change Project in response to its Ocean Acidification Task. The application, by Mark Hansen and Lisa Robbins, USGS St. Petersburg, FL, Joanie Kleypas, NCAR, Boulder, CO, and Stephan Meylan, Jacobs Technology, St. Petersburg, FL, is intended as a follow-on to CO2SYS, originally developed by Lewis and Wallace (1998) and later modified for Microsoft Excel? by Denis Pierrot (Pierrot and others, 2006). Besides eliminating the need for using Microsoft Excel on the host system, CO2calc offers several improvements on CO2SYS, including: An improved graphical user interface for data entry and results Additional calculations of air-sea CO2 fluxes (for surface water calculations) The ability to tag data with sample name, comments, date, time, and latitude/longitude The ability to use the system time and date and latitude/ longitude (automatic retrieval of latitude and longitude available on iPhone? 3, 3GS, 4, and Windows? hosts with an attached National Marine Electronics Association (NMEA)-enabled GPS) The ability to process multiple files in a batch processing mode An option to save sample information, data input, and calculated results as a comma-separated value (CSV) file for use with Microsoft Excel, ArcGIS,? or other applications An option to export points with geographic coordinates as a KMZ file for viewing and editing in Google EarthTM
Yakami, Masahiro; Ishizu, Koichi; Kubo, Takeshi; Okada, Tomohisa; Togashi, Kaori
2011-04-01
Thin-slice CT data, useful for clinical diagnosis and research, is now widely available but is typically discarded in many institutions, after a short period of time due to data storage capacity limitations. We designed and built a low-cost high-capacity Digital Imaging and COmmunication in Medicine (DICOM) storage system able to store thin-slice image data for years, using off-the-shelf consumer hardware components, such as a Macintosh computer, a Windows PC, and network-attached storage units. "Ordinary" hierarchical file systems, instead of a centralized data management system such as relational database, were adopted to manage patient DICOM files by arranging them in directories enabling quick and easy access to the DICOM files of each study by following the directory trees with Windows Explorer via study date and patient ID. Software used for this system was open-source OsiriX and additional programs we developed ourselves, both of which were freely available via the Internet. The initial cost of this system was about $3,600 with an incremental storage cost of about $900 per 1 terabyte (TB). This system has been running since 7th Feb 2008 with the data stored increasing at the rate of about 1.3 TB per month. Total data stored was 21.3 TB on 23rd June 2009. The maintenance workload was found to be about 30 to 60 min once every 2 weeks. In conclusion, this newly developed DICOM storage system is useful for research due to its cost-effectiveness, enormous capacity, high scalability, sufficient reliability, and easy data access.
Glnemo2: Interactive Visualization 3D Program
NASA Astrophysics Data System (ADS)
Lambert, Jean-Charles
2011-10-01
Glnemo2 is an interactive 3D visualization program developed in C++ using the OpenGL library and Nokia QT 4.X API. It displays in 3D the particles positions of the different components of an nbody snapshot. It quickly gives a lot of information about the data (shape, density area, formation of structures such as spirals, bars, or peanuts). It allows for in/out zooms, rotations, changes of scale, translations, selection of different groups of particles and plots in different blending colors. It can color particles according to their density or temperature, play with the density threshold, trace orbits, display different time steps, take automatic screenshots to make movies, select particles using the mouse, and fly over a simulation using a given camera path. All these features are accessible from a very intuitive graphic user interface. Glnemo2 supports a wide range of input file formats (Nemo, Gadget 1 and 2, phiGrape, Ramses, list of files, realtime gyrfalcON simulation) which are automatically detected at loading time without user intervention. Glnemo2 uses a plugin mechanism to load the data, so that it is easy to add a new file reader. It's powered by a 3D engine which uses the latest OpenGL technology, such as shaders (glsl), vertex buffer object, frame buffer object, and takes in account the power of the graphic card used in order to accelerate the rendering. With a fast GPU, millions of particles can be rendered in real time. Glnemo2 runs on Linux, Windows (using minGW compiler), and MaxOSX, thanks to the QT4API.
Jeevanandan, Ganesh; Thomas, Eapen
2018-01-01
This present study was conducted to analyze the volumetric change in the root canal space and instrumentation time between hand files, hand files in reciprocating motion, and three rotary files in primary molars. One hundred primary mandibular molars were randomly allotted to one of the five groups. Instrumentation was done using Group I; nickel-titanium (Ni-Ti) hand file, Group II; Ni-Ti hand files in reciprocating motion, Group III; Race rotary files, Group IV; prodesign pediatric rotary files, and Group V; ProTaper rotary files. The mean volumetric changes were assessed using pre- and post-operative spiral computed tomography scans. Instrumentation time was recorded. Statistical analysis to access intergroup comparison for mean canal volume and instrumentation time was done using Bonferroni-adjusted Mann-Whitney test and Mann-Whitney test, respectively. Intergroup comparison of mean canal volume showed statistically significant difference between Groups II versus IV, Groups III versus V, and Groups IV versus V. Intergroup comparison of mean instrumentation time showed statistically significant difference among all the groups except Groups IV versus V. Among the various instrumentation techniques available, rotary instrumentation is the considered to be the better instrumentation technique for canal preparation in primary teeth.
Three-Dimensional Audio Client Library
NASA Technical Reports Server (NTRS)
Rizzi, Stephen A.
2005-01-01
The Three-Dimensional Audio Client Library (3DAudio library) is a group of software routines written to facilitate development of both stand-alone (audio only) and immersive virtual-reality application programs that utilize three-dimensional audio displays. The library is intended to enable the development of three-dimensional audio client application programs by use of a code base common to multiple audio server computers. The 3DAudio library calls vendor-specific audio client libraries and currently supports the AuSIM Gold-Server and Lake Huron audio servers. 3DAudio library routines contain common functions for (1) initiation and termination of a client/audio server session, (2) configuration-file input, (3) positioning functions, (4) coordinate transformations, (5) audio transport functions, (6) rendering functions, (7) debugging functions, and (8) event-list-sequencing functions. The 3DAudio software is written in the C++ programming language and currently operates under the Linux, IRIX, and Windows operating systems.
PhamDB: a web-based application for building Phamerator databases.
Lamine, James G; DeJong, Randall J; Nelesen, Serita M
2016-07-01
PhamDB is a web application which creates databases of bacteriophage genes, grouped by gene similarity. It is backwards compatible with the existing Phamerator desktop software while providing an improved database creation workflow. Key features include a graphical user interface, validation of uploaded GenBank files, and abilities to import phages from existing databases, modify existing databases and queue multiple jobs. Source code and installation instructions for Linux, Windows and Mac OSX are freely available at https://github.com/jglamine/phage PhamDB is also distributed as a docker image which can be managed via Kitematic. This docker image contains the application and all third party software dependencies as a pre-configured system, and is freely available via the installation instructions provided. snelesen@calvin.edu. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
Çiçek, Ersan; Koçak, Mustafa Murat; Koçak, Sibel; Sağlam, Baran Can
2016-01-01
The type of instrument affects the amount of debris extruded. The aim of this study was to compare the effect of retreatment systems and supplementary file application on the amount of apical debris extrusion. Forty-eight extracted mandibular premolars with a single canal and similar length were selected. The root canals were prepared with the ProTaper Universal system with a torque-controlled engine. The root canals were dried and were obturated using Gutta-percha and sealer. The specimens were randomly divided into four equal groups according to the retreatment procedures (Group 1, Mtwo retreatment files; Group 2, Mtwo retreatment files + Mtwo rotary file #30 supplementary file; Group 3, ProTaper Universal retreatment (PTUR) files; and Group 4, PTUR files + ProTaper F3 supplementary file). The extruded debris during instrumentation were collected into preweighed Eppendorf tubes. The amount of apically extruded debris was calculated by subtracting the initial weight of the tube from the final weight. Three consecutive weights were obtained for each tube. No statistically significant difference was found in the amount of apically extruded debris between Groups 1 and 3 (P = 0.590). A significant difference was observed between Groups 1 and 2 (P < 0.05), and between Groups 3 and 4 (P < 0.05). The use of supplementary file significantly increased the amount of apically extruded debris.
Evaluation of a new filing system's ability to maintain canal morphology.
Thompson, Matthew; Sidow, Stephanie J; Lindsey, Kimberly; Chuang, Augustine; McPherson, James C
2014-06-01
The manufacturer of the Hyflex CM endodontic files claims the files remain centered within the canal, and if unwound during treatment, they will regain their original shape after sterilization. The purpose of this study was to evaluate and compare the canal centering ability of the Hyflex CM and the ProFile ISO filing systems after repeated uses in simulated canals, followed by autoclaving. Sixty acrylic blocks with a canal curvature of 45° were stained with methylene blue, photographed, and divided into 2 groups, H (Hyflex CM) and P (ProFile ISO). The groups were further subdivided into 3 subgroups: H1, H2, H3; P1, P2, P3 (n = 10). Groups H1 and P1 were instrumented to 40 (.04) with the respective file system. Used files were autoclaved for 26 minutes at 126°C. After sterilization, the files were used to instrument groups H2 and P2. The same sterilization and instrumentation procedure was repeated for groups H3 and P3. Post-instrumentation digital images were taken and superimposed over the pre-instrumentation images. Changes in the location of the center of the canal at predetermined reference points were recorded and compared within subgroups and between filing systems. Statistical differences in intergroup and intragroup transportation measures were analyzed by using the Kruskal-Wallis analysis of variance of ranks with the Bonferroni post hoc test. There was a difference between Hyflex CM and ProFile ISO groups, although it was not statistically significant. Intragroup differences for both Hyflex CM and ProFile ISO groups were not significant (P < .05). The Hyflex CM and ProFile ISO files equally maintained the original canal's morphology after 2 sterilization cycles. Published by Elsevier Inc.
Matwychuk, Michael J; Bowles, Walter R; McClanahan, Scott B; Hodges, Jim S; Pesun, Igor J
2007-07-01
The purpose of this study was to compare apical transportation, working-length changes, and instrumentation time by using nickel-titanium (Ni-Ti) rotary file systems (crown-down method) or stainless steel hand files (balanced-force technique) in mesiobuccal canals of extracted mandibular molars. The curvature of each canal was determined and teeth placed into three equivalent groups. Group 1 was instrumented with Sequence (Brasseler USA, Savannah, GA) rotary files, group 2 with Liberator (Miltex Inc, York, PA) rotary files, and group 3 with Flex-R (Union Broach, New York, NY) files. Pre- and postoperative radiographs were superimposed to measure loss of working length and apical transportation as shown by changes in radius of curvature and the long-axis canal angle. Sequence rotary files, Liberator rotary files, and Flex-R hand files had similar effects on apical canal transportation and changes in working length, with no significant differences detected among the 3 groups. Hand instrumentation times were longer than with either Ni-Ti rotary group, whereas the rotary NiTi groups had a higher incidence of fracture.
Effect of reciprocating file motion on microcrack formation in root canals: an SEM study.
Ashwinkumar, V; Krithikadatta, J; Surendran, S; Velmurugan, N
2014-07-01
To compare dentinal microcrack formation whilst using Ni-Ti hand K-files, ProTaper hand and rotary files and the WaveOne reciprocating file. One hundred and fifty mandibular first molars were selected. Thirty teeth were left unprepared and served as controls, and the remaining 120 teeth were divided into four groups. Ni-Ti hand K-files, ProTaper hand files, ProTaper rotary files and WaveOne Primary reciprocating files were used to prepare the mesial canals. Roots were then sectioned 3, 6 and 9 mm from the apex, and the cut surface was observed under scanning electron microscope (SEM) and checked for the presence of dentinal microcracks. The control and Ni-Ti hand K-files groups were not associated with microcracks. In roots prepared with ProTaper hand files, ProTaper rotary files and WaveOne Primary reciprocating files, dentinal microcracks were present. There was a significant difference between control/Ni-Ti hand K-files group and ProTaper hand files/ProTaper rotary files/WaveOne Primary reciprocating file group (P < 0.001) with ProTaper rotary files producing the most microcracks. No significant difference was observed between teeth prepared with ProTaper hand files and WaveOne Primary reciprocating files. ProTaper rotary files were associated with significantly more microcracks than ProTaper hand files and WaveOne Primary reciprocating files. Ni-Ti hand K-files did not produce microcracks at any levels inside the root canals. © 2013 International Endodontic Journal. Published by John Wiley & Sons Ltd.
Saha, Suparna Ganguly; Vijaywargiya, Neelam; Saxena, Divya; Saha, Mainak Kanti; Bharadwaj, Anuj; Dubey, Sandeep
2017-01-01
Introduction: To evaluate the incidence of microcrack formation canal preparation with two rotary nickel–titanium systems Mtwo and ProTaper Next along with the self-adjusting file system. Materials and Methods: One hundred and twenty mandibular premolar teeth were selected. Standardized access cavities were prepared and the canals were manually prepared up to size 20 after coronal preflaring. The teeth were divided into three experimental groups and one control group (n = 30). Group 1: The canals were prepared using Mtwo rotary files. Group 2: The canals were prepared with ProTaper Next files. Group 3: The canals were prepared with self-adjusting files. Group 4: The canals were unprepared and used as a control. The roots were sectioned horizontally 3, 6, and 9 mm from the apex and examined under a scanning electron microscope to check for the presence of microcracks. The Pearson's Chi-square test was applied. Results: The highest incidence of microcracks were associated with the ProTaper Next group, 80% (P = 0.00), followed by the Mtwo group, 70% (P = 0.000), and the least number of microcracks was noted in the self-adjusting file group, 10% (P = 0.068). No significant difference was found between the ProTaper Next and Mtwo groups (P = 0.368) while a significant difference was observed between the ProTaper Next and self-adjusting file groups (P = 0.000) as well as the Mtwo and self-adjusting file groups (P = 0.000). Conclusion: All nickel–titanium rotary instrument systems were associated with microcracks. However, the self-adjusting file system had significantly fewer microcracks when compared with the Mtwo and ProTaper Next. PMID:29386786
Saha, Suparna Ganguly; Vijaywargiya, Neelam; Saxena, Divya; Saha, Mainak Kanti; Bharadwaj, Anuj; Dubey, Sandeep
2017-01-01
To evaluate the incidence of microcrack formation canal preparation with two rotary nickel-titanium systems Mtwo and ProTaper Next along with the self-adjusting file system. One hundred and twenty mandibular premolar teeth were selected. Standardized access cavities were prepared and the canals were manually prepared up to size 20 after coronal preflaring. The teeth were divided into three experimental groups and one control group ( n = 30). Group 1: The canals were prepared using Mtwo rotary files. Group 2: The canals were prepared with ProTaper Next files. Group 3: The canals were prepared with self-adjusting files. Group 4: The canals were unprepared and used as a control. The roots were sectioned horizontally 3, 6, and 9 mm from the apex and examined under a scanning electron microscope to check for the presence of microcracks. The Pearson's Chi-square test was applied. The highest incidence of microcracks were associated with the ProTaper Next group, 80% ( P = 0.00), followed by the Mtwo group, 70% ( P = 0.000), and the least number of microcracks was noted in the self-adjusting file group, 10% ( P = 0.068). No significant difference was found between the ProTaper Next and Mtwo groups ( P = 0.368) while a significant difference was observed between the ProTaper Next and self-adjusting file groups ( P = 0.000) as well as the Mtwo and self-adjusting file groups ( P = 0.000). All nickel-titanium rotary instrument systems were associated with microcracks. However, the self-adjusting file system had significantly fewer microcracks when compared with the Mtwo and ProTaper Next.
Hilfer, Paul B; Bergeron, Brian E; Mayerchak, Michael J; Roberts, Howard W; Jeansonne, Billie G
2011-01-01
Novel nickel-titanium rotary files with proprietary manufacturing techniques have recently been marketed. The purpose of this study was to assess multiple autoclave cycle effects on cyclic fatigue of GT Series X files (Dentsply Tulsa Dental Specialties, Tulsa, OK) and Twisted Files (SybronEndo, Orange, CA) METHODS: A jig using a 5-mm radius curve with 90° of maximum file flexure was used to induce cyclic fatigue failure. Files (n = 10) representing each experimental group (GT Series X 20/.04 and 20/.06; Twisted Files 25/.04 and 25/.06) were first tested to establish baseline mean cycles to failure (MCF). Experimental groups (n = 20) were then cycled to 25% of the established baseline MCF and then autoclaved. Additional autoclaving was accomplished at 50% and 75% of MCF followed by continual testing until failure. Control groups (n = 20) underwent the same procedures except autoclaving was not accomplished. The GT Series X (20/.04 and 20/.06) files showed no significant difference (p = 0.918/p = 0.096) in MCF for experimental versus control files. Twisted Files (25/.04) showed no significant difference (p = 0.432) in MCF between experimental and control groups. However, the Twisted Files (25/.06) experimental group showed a significantly lower (p = 0.0175) MCF compared with the controls. Under the conditions of this evaluation, autoclave sterilization significantly decreased cyclic fatigue resistance of one of the four file groups tested. Repeated autoclaving significantly reduced the MCF of 25/.06 Twisted Files; however, 25/.04 Twisted Files and both GT Series X files tested were not significantly affected by the same conditions. Published by Elsevier Inc.
Harb, Francine; Hidalgo, Maria Paz; Martau, Betina
2015-04-01
The diurnal light cycle has a crucial influence on all life on earth. Unfortunately, modern society has modified this life-governing cycle by stressing maximum production and by giving insufficient attention to the ecological balance and homeostasis of the human metabolism. The aim of this study is to evaluate the effects of exposure or lack of exposure to natural light in a rest/activity rhythm on cortisol and melatonin levels, as well as on psychological variables in humans under natural conditions. This is a cross-sectional study. The subjects were allocated split into two groups according to their workspace (10 employees in the "with window" group and 10 in the "without window" group). All participants were women and wore anactigraph (Actiwatch 2, Philips Respironics), which measures activity and ambient light exposure, for seven days. Concentrations of melatonin and cortisol were measured from the saliva samples. Participants were instructed to collect saliva during the last day of use of the actigraph at 08:00 am, 4:00 pm and 10:00 pm. The subjects answered the Self-Reporting Questionnaire-20 (SRQ-20) to measure the presence of minor psychiatric disorders; the Montgomery-Asberg (MA) scale was used to measure depression symptoms, and the Pittsburgh Sleep Quality Index questionnaire (PSQI) was used to evaluate the quality of sleep. The Rayleigh analysis indicates that the two groups, "with window" an d "without window", exhibited similar activities and light acrophases. In relation to light exposure, the mesor was significantly higher (t = -2.651, p = 0.023) in t he "with window" group (191.04 ± 133.36) than in the "without window" group (73.8 ± 42.05). Additionally, the "with window" group presented the highest amplitude of light exposure (298.07 ± 222.97). Cortisol levels were significantly different between the groups at 10:00 pm (t = 3.009, p = 0.008; "without window" (4.01 ± 0.91) "with window" (3.10 ± 0.30)). In terms of the melatonin levels, the groups differed at two different times of day: 08:00 am (t = 2.593, p = 0.018) and 10:00 pm (t = -2.939, p = 0.009). The "with window" group had a lower melatonin level at 08:00 am (3.54 ± 0.60) but a higher level at 10:00 pm (24.74 ± 4.22) than the "without window" group. Higher cortisol levels were positively correlated with minor psychiatric disorders and depressive symptoms (MA) at 10:00 pm. Lower melatonin levels at 10:00 pm were correlated with depressive symptoms and poor quality of sleep (PSQI). Our study demonstrated that not only may light pollution affect human physiology but also lack of exposure to natural light is related to high levels of cortisol and lower levels of melatonin at night, and these, in turn, are related to depressive symptoms and poor quality of sleep.
Oval Window Size and Shape: a Micro-CT Anatomical Study With Considerations for Stapes Surgery.
Zdilla, Matthew J; Skrzat, Janusz; Kozerska, Magdalena; Leszczyński, Bartosz; Tarasiuk, Jacek; Wroński, Sebastian
2018-06-01
The oval window is an important structure with regard to stapes surgeries, including stapedotomy for the treatment of otosclerosis. Recent study of perioperative imaging of the oval window has revealed that oval window niche height can indicate both operative difficulty and subjective discomfort during otosclerosis surgery. With regard to shape, structures incorporated into the oval window niche, such as cartilage grafts, must be compatible with the shape of the oval window. Despite the clinical importance of the oval window, there is little information regarding its size and shape. This study assessed oval window size and shape via micro-computed tomography paired with modern morphometric methodology in the fetal, infant, child, and adult populations. Additionally, the study compared oval window size and shape between sexes and between left- and right-sided ears. No significant differences were found among traditional morphometric parameters among age groups, sides, or sexes. However, geometric morphometric methods revealed shape differences between age groups. Further, geometric morphometric methods provided the average oval window shape and most-likely shape variance. Beyond demonstrating oval window size and shape variation, the results of this report will aid in identifying patients among whom anatomical variation may contribute to surgical difficulty and surgeon discomfort, or otherwise warrant preoperative adaptations for the incorporation of materials into and around the oval window.
Using the Shuttle In Situ Window and Radiator Data for Meteoroid Measurements
NASA Technical Reports Server (NTRS)
Matney, Mark
2015-01-01
Every time NASA's Space Shuttle flew in orbit, it was exposed to the natural meteoroid and artificial debris environment. NASA Johnson Space Center maintains a database of impact cratering data of 60 Shuttle missions flown since the mid-1990's that were inspected after flight. These represent a total net exposure time to the space environment of 2 years. Impact damage was recorded on the windows and radiators, and in many cases information on the impactor material was determined by later analysis of the crater residue. This information was used to segregate damage caused by natural meteoroids and artificial space debris. The windows represent a total area of 3.565 sq m, and were capable of resolving craters down to about 10 micrometers in size. The radiators represent a total area of 119.26 sq m, and saw damage from objects up to approximately 1 mm in diameter. These data were used extensively in the development of NASA's ORDEM 3.0 Orbital Debris Environment Model, and gives a continuous picture of the orbital debris environment in material type and size ranging from about 10 micrometers to 1 mm. However, the meteoroid data from the Shuttles have never been fully analyzed. For the orbital debris work, special "as flown" files were created that tracked the pointing of the surface elements and their shadowing by structure (such as the ISS during docking). Unfortunately, such files for the meteoroid environment have not yet been created. This talk will introduce these unique impact data and describe how they were used for orbital debris measurements. We will then discuss some simple first-order analyses of the meteoroid data, and point the way for future analyses.
Visualization Development of the Ballistic Threat Geospatial Optimization
2015-07-01
topographic globes, Keyhole Markup Language (KML), and Collada files. World Wind gives the user the ability to import 3-D models and navigate...present. After the first person view window is closed , the images stored in memory are then converted to a QuickTime movie (.MOV). The video will be...processing unit HPC high-performance computing JOGL Java implementation of OpenGL KML Keyhole Markup Language NASA National Aeronautics and Space
MEA-Tools: an open source toolbox for the analysis of multi-electrode data with MATLAB.
Egert, U; Knott, Th; Schwarz, C; Nawrot, M; Brandt, A; Rotter, S; Diesmann, M
2002-05-30
Recent advances in electrophysiological techniques have created new tools for the acquisition and storage of neuronal activity recorded simultaneously with numerous electrodes. These techniques support the analysis of the function as well as the structure of individual electrogenic cells in the context of surrounding neuronal or cardiac network. Commercially available tools for the analysis of such data, however, cannot be easily adapted to newly emerging requirements for data analysis and visualization, and cross compatibility between them is limited. In this report we introduce a free open source toolbox called microelectrode array tools (MEA-Tools) for the analysis of multi-electrode data based on the common data analysis environment MATLAB (version 5.3-6.1, The Mathworks, Natick, MA). The toolbox itself is platform independent. The file interface currently supports files recorded with MCRack (Multi Channel Systems, Reutlingen, Germany) under Microsoft Windows 95, 98, NT, and 2000, but can be adapted to other data acquisition systems. Functions are controlled via command line input and graphical user interfaces, and support common requirements for the analysis of local field potentials, extracellular spike activity, and continuous recordings, in addition to supplementary data acquired by additional instruments, e.g. intracellular amplifiers. Data may be processed as continuous recordings or time windows triggered to some event.
Astrometrica: Astrometric data reduction of CCD images
NASA Astrophysics Data System (ADS)
Raab, Herbert
2012-03-01
Astrometrica is an interactive software tool for scientific grade astrometric data reduction of CCD images. The current version of the software is for the Windows 32bit operating system family. Astrometrica reads FITS (8, 16 and 32 bit integer files) and SBIG image files. The size of the images is limited only by available memory. It also offers automatic image calibration (Dark Frame and Flat Field correction), automatic reference star identification, automatic moving object detection and identification, and access to new-generation star catalogs (PPMXL, UCAC 3 and CMC-14), in addition to online help and other features. Astrometrica is shareware, available for use for a limited period of time (100 days) for free; special arrangements can be made for educational projects.
77 FR 15388 - Notice of Filing of Plats of Survey; Arizona
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-15
..., 2012, and officially filed January 31, 2012, for Group 1074, Arizona. This plat was prepared at the..., accepted January 26, 2012, and officially filed January 31, 2012, for Group 1074, Arizona. This plat was... 26, 2012, and officially filed January 31, 2012, for Group 1074, Arizona. This plat was prepared at...
77 FR 59692 - 2014 Diversity Immigrant Visa Program
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-28
... the E-DV system. The entry will not be accepted and must be resubmitted. Group or family photographs... must be in the Joint Photographic Experts Group (JPEG) format. Image File Size: The maximum file size...). Image File Format: The image must be in the Joint Photographic Experts Group (JPEG) format. Image File...
HST archive primer, version 4.1
NASA Technical Reports Server (NTRS)
Fruchter, A. (Editor); Baum, S. (Editor)
1994-01-01
This version of the HST Archive Primer provides the basic information a user needs to know to access the HST archive via StarView the new user interface to the archive. Using StarView, users can search for observations interest, find calibration reference files, and retrieve data from the archive. Both the terminal version of StarView and the X-windows version feature a name resolver which simplifies searches of the HST archive based on target name. In addition, the X-windows version of StarView allows preview of all public HST data; compressed versions of public images are displayed via SAOIMAGE, while spectra are plotted using the public plotting package, XMGR. Finally, the version of StarView described here features screens designed for observers preparing Cycle 5 HST proposals.
A Simple Compression Scheme Based on ASCII Value Differencing
NASA Astrophysics Data System (ADS)
Tommy; Siregar, Rosyidah; Lubis, Imran; Marwan E, Andi; Mahmud H, Amir; Harahap, Mawaddah
2018-04-01
ASCII characters have a different code representation where each character has a different numeric value between the characters to each other. The characters is usually used as a text message communication has the representation of a numeric code to each other or have a small difference. The value of the difference can be used as a substitution of the characters so it will generate a new message with a size that is a little more. This paper discusses the utilization value of the difference of characters ASCII in a message to a much simpler substitution by using a dynamic-sized window in order to obtain the difference from ASCII value contained on the window as the basis in determining the bit substitution on the file compression results.
Forensic Analysis of Windows Hosts Using UNIX-based Tools
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cory Altheide
2004-07-19
Many forensic examiners are introduced to UNIX-based forensic utilities when faced with investigating a UNIX-like operating system for the first time. They will use these utilities for this very specific task, because in many cases these tools are the only ones for the given job. For example, at the time of this writing, given a FreeBSD 5.x file system, the author's only choice is to use The Coroner's Toolkit running on FreeBSD 5.x. However, many of the same tools examiners use for the occasional UNIX-like system investigation are extremely capable when a Windows system is the target. Indeed, the Linuxmore » operating system itself can prove to be an extremely useful forensics platform with very little use of specialized forensics utilities at all.« less
Yu, Huajie; He, Danqing; Qiu, Lixin
2017-12-01
Maturation of the grafted volume after lateral sinus elevation is crucial for the long-term survival of dental implants. To compare endo-sinus histomorphometric bone formation between the solo- and two-window maxillary sinus augmentation techniques with or without membrane coverage for the rehabilitation of multiple missing posterior teeth. Patients with severely atrophic posterior maxillae were randomized to receive lateral sinus floor elevation via the solo-window technique with membrane coverage (Control Group) or the two-window technique without coverage (Test Group). Six months after surgery, bone core specimens harvested from the lateral aspect were histomorphometrically analyzed. Ten patients in each group underwent 21 maxillary sinus augmentations. Histomorphometric analysis revealed mean newly formed bone values of 26.08 ± 16.23% and 27.14 ± 18.11%, mean connective tissue values of 59.34 ± 12.42% and 50.03 ± 17.13%, and mean residual graft material values of 14.6 ± 14.56% and 22.78 ± 10.83% in the Test and Control Groups, respectively, with no significant differences. The two-window technique obtained comparative maturation of the grafted volume even without membrane coverage, and is a viable alternative for the rehabilitation of severely atrophic posterior maxillae with multiple missing posterior teeth. © 2017 Wiley Periodicals, Inc.
Software for Allocating Resources in the Deep Space Network
NASA Technical Reports Server (NTRS)
Wang, Yeou-Fang; Borden, Chester; Zendejas, Silvino; Baldwin, John
2003-01-01
TIGRAS 2.0 is a computer program designed to satisfy a need for improved means for analyzing the tracking demands of interplanetary space-flight missions upon the set of ground antenna resources of the Deep Space Network (DSN) and for allocating those resources. Written in Microsoft Visual C++, TIGRAS 2.0 provides a single rich graphical analysis environment for use by diverse DSN personnel, by connecting to various data sources (relational databases or files) based on the stages of the analyses being performed. Notable among the algorithms implemented by TIGRAS 2.0 are a DSN antenna-load-forecasting algorithm and a conflict-aware DSN schedule-generating algorithm. Computers running TIGRAS 2.0 can also be connected using SOAP/XML to a Web services server that provides analysis services via the World Wide Web. TIGRAS 2.0 supports multiple windows and multiple panes in each window for users to view and use information, all in the same environment, to eliminate repeated switching among various application programs and Web pages. TIGRAS 2.0 enables the use of multiple windows for various requirements, trajectory-based time intervals during which spacecraft are viewable, ground resources, forecasts, and schedules. Each window includes a time navigation pane, a selection pane, a graphical display pane, a list pane, and a statistics pane.
78 FR 44591 - Notice of Filing of Plats of Survey; Arizona
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-24
... East, accepted April 5, 2013, and officially filed April 9, 2013, for Group 1101, Arizona. This plat... officially filed April 9, 2013, for Group 1101, Arizona. This plat was prepared at the request of the United..., 2013, and officially filed April 9, 2013, for Group 1101, Arizona. This plat was prepared at the...
Taneja, Sonali; Kumari, Manju; Barua, Madhumita; Dudeja, Chetna; Malik, Meeta
2015-01-01
To compare the apical extrusion of Enterococcus faecalis after instrumentation with three different Ni-Ti rotary instruments- An in vitro study. In vitro study Methods and Material: Forty freshly extracted mandibular premolars were mounted in bacteria collection apparatus and root canals were contaminated with a suspension of Enterococcus faecalis. The contaminated teeth were divided into 4 groups of 10 teeth each according to rotary system used for instrumentation: Group1: Hyflex files, Group 2: GTX files, Group 3: Protaper files and Group 4: control group (no instrumentation). Bacteria extruded after preparations were collected into vials and microbiological samples were incubated in BHI broth for 24 hrs. The colony forming units were determined for each sample. Statistical analysis was done using one way ANOVA followed by post hoc independent " t" test. GTX files extruded least amount of bacteria followed by Hyflex files. Maximum extrusion of E. faecalis was seen in rotary Protaper group. Least amount of extrusion was seen with GTX files followed by Hyflex files and then rotary Protaper system.
Kfir, Anda; Moza-Levi, Rotem; Herteanu, Moran; Weissman, Amir; Wigler, Ronald
2018-03-01
The purpose of this study was to assess the amount of apically extruded debris during the preparation of oval canals with either a rotary file system supplemented by the XP-endo Finisher file or a full-sequence self-adjusting file (SAF) system. Sixty mandibular incisors were randomly assigned to two groups: group A: stage 1-glide path preparation with Pre-SAF instruments. Stage 2-cleaning and shaping with SAF. Group B: stage 1-glide path preparation with ProGlider file. Stage 2-cleaning and shaping with ProTaper Next system. Stage 3-Final cleaning with XP-endo Finisher file. The debris extruded during each of the stages was collected, and the debris weights were compared between the groups and between the stages within the groups using t tests with a significance level set at P < 0.05. The complete procedure for group B resulted in significantly more extruded debris compared to group A. There was no significant difference between the stages in group A, while there was a significant difference between stage 2 and stages 1 and 3 in group B, but no significant difference between stages 1 and 3. Both instrumentation protocols resulted in extruded debris. Rotary file followed by XP-endo Finisher file extruded significantly more debris than a full-sequence SAF system. Each stage, in either procedure, had its own contribution to the extrusion of debris. Final preparation with XP-endo Finisher file contributes to the total amount of extruded debris, but the clinical relevance of the relative difference in the amount of apically extruded debris remains unclear.
Karataşlıoglu, E; Aydın, U; Yıldırım, C
2018-02-01
The aim of this in vitro study was to compare the static cyclic fatigue resistance of thermal treated rotary files with a conventional nickel-titanium (NiTi) rotary file. Four groups of 60 rotary files with similar file dimensions, geometries, and motion were selected. Groups were set as HyFlex Group [controlled memory wire (CM-Wire)], ProfileVortex Group (M-Wire), Twisted File Group (R-Phase Wire), and OneShape Group (conventional NiTi wire)] and tested using a custom-made static cyclic fatigue testing apparatus. The fracture time and fragment length of the each file was also recorded. Statistical analysis was performed using one-way analysis of variance and Tukey's test at the 95% confidence level (P = 0.05). The HyFlex group had a significantly higher mean cyclic fatigue resistance than the other three groups (P < 0.001). The OneShape groups had the least fatigue resistance. CM-Wire alloy represented the best performance in cyclic fatigue resistance, and NiTi alloy in R-Phase had the second highest fatigue resistance. CM and R-Phase manufacturing technology processed to the conventional NiTi alloy enhance the cyclic fatigue resistance of files that have similar design and size. M-wire alloy did not show any superiority in cyclic fatigue resistance when compared with conventional NiTi wire.
Naumova, Vera V.; Patuk, Mikhail I.; Kapitanchuk, Marina Yu.; Nokleberg, Warren J.; Khanchuk, Alexander I.; Parfenov, Leonid M.; Rodionov, Sergey M.; Miller, Robert J.; Diggles, Michael F.
2006-01-01
This is the online version of a CD-ROM publication. It contains all of the data that are on the disc but extra files have been removed: index files, software installers, and Windows autolaunch files. The purpose of this publication is to provide a high-quality spatial data compilation (Geographical Information System or GIS) of geodynamic, mineral deposit, and metallogenic belt maps, and descriptive data for Northeast Asia for customers and users. This area consists of Eastern Siberia, Russian Far East, Mongolia, northern China, South Korea, and Japan. The GIS compilation contains integrated spatial data for: (1) a geodynamics map at a scale of 1:5,000,000; (2) a mineral deposit location map; (3) metallogenic belt maps; (4) detailed descriptions of geologic units, including tectonostratigraphic terranes, cratons, major melange zones, and overlap assemblages, with references; (5) detailed descriptions of metallogenic belts with references; (6) detailed mineral deposit descriptions with references; and (7) page-size stratigraphic columns for major terranes.
Biomechanical ToolKit: Open-source framework to visualize and process biomechanical data.
Barre, Arnaud; Armand, Stéphane
2014-04-01
C3D file format is widely used in the biomechanical field by companies and laboratories to store motion capture systems data. However, few software packages can visualize and modify the integrality of the data in the C3D file. Our objective was to develop an open-source and multi-platform framework to read, write, modify and visualize data from any motion analysis systems using standard (C3D) and proprietary file formats (used by many companies producing motion capture systems). The Biomechanical ToolKit (BTK) was developed to provide cost-effective and efficient tools for the biomechanical community to easily deal with motion analysis data. A large panel of operations is available to read, modify and process data through C++ API, bindings for high-level languages (Matlab, Octave, and Python), and standalone application (Mokka). All these tools are open-source and cross-platform and run on all major operating systems (Windows, Linux, MacOS X). Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Kakooei, Hossein; Shahtaheri, Seyed Jamaleddin; Karbasi, Hossein-Ali
2006-01-01
Evaluation of personal inhalation exposure to methylene diphenyl diisocyanate (MDI) among 39 employees, working in the window fixation and window glue processes in an automobile manufacturing company was performed. This study was conducted for both case and control groups. After sampling and sample preparation processes, MDI was determined with a UV-VIS spectrophotometer at 590 nm; the lung function was assessed with a digital spirometer, too. The average concentration of MDI in the window fixation, and window glue workplaces were 34.53 and 27.37 micro g/m3, respectively, which was lower than the threshold limit value (TLV) recommended by the American Conference of Governmental Industrial Hygienists (ACGIH) (51 micro g/m3). Respiratory symptoms in the exposed group were significantly different compared to the unexposed group (p < .05). Lung capacities in the case group were lower than in the control group (p < .05). Therefore, MDI can be easily measured making it possible to evaluate the adverse effects caused by occupational exposure.
Retrieving high-resolution images over the Internet from an anatomical image database
NASA Astrophysics Data System (ADS)
Strupp-Adams, Annette; Henderson, Earl
1999-12-01
The Visible Human Data set is an important contribution to the national collection of anatomical images. To enhance the availability of these images, the National Library of Medicine has supported the design and development of a prototype object-oriented image database which imports, stores, and distributes high resolution anatomical images in both pixel and voxel formats. One of the key database modules is its client-server Internet interface. This Web interface provides a query engine with retrieval access to high-resolution anatomical images that range in size from 100KB for browser viewable rendered images, to 1GB for anatomical structures in voxel file formats. The Web query and retrieval client-server system is composed of applet GUIs, servlets, and RMI application modules which communicate with each other to allow users to query for specific anatomical structures, and retrieve image data as well as associated anatomical images from the database. Selected images can be downloaded individually as single files via HTTP or downloaded in batch-mode over the Internet to the user's machine through an applet that uses Netscape's Object Signing mechanism. The image database uses ObjectDesign's object-oriented DBMS, ObjectStore that has a Java interface. The query and retrieval systems has been tested with a Java-CDE window system, and on the x86 architecture using Windows NT 4.0. This paper describes the Java applet client search engine that queries the database; the Java client module that enables users to view anatomical images online; the Java application server interface to the database which organizes data returned to the user, and its distribution engine that allow users to download image files individually and/or in batch-mode.
Priya, N Tulasi; Chandrasekhar, Veeramachaneni; Anita, S; Tummala, Muralidhar; Raj, T B Phanindhar; Badami, Vijetha; Kumar, Pradeep; Soujanya, E
2014-12-01
The purpose of this study was to compare the incidence of dentinal micro cracks after instrumentation with various types of NiTi files in rotary and reciprocating motion. One hundred human extracted mandibular central incisors were taken and divided into 10 groups (n=10 teeth per group). Group 1- No preparation, Group 2 - Hand instrumentation, Groups 3,4 - ProTaper files in rotary and reciprocating motion, Groups 5,6 - ProTaper Next files in rotary and reciprocating motion, Groups 7,8 - Oneshape files in rotary and reciprocating motion, Groups 9,10 - Reciproc files in rotary and reciprocating motion. Specimens were sectioned horizontally at 3,6 and 9 mm from the apex and dentinal micro cracks were observed under a stereomicroscope. There was a statistically significant difference between the groups (p<0.05). There were no significant differences in crack formation between the groups (Protaper Next - Rot, Protaper Next - Rec, Reciproc - Rec); (ProTaper - Rot, ProTaper - Rec, Oneshape - Rot), (Oneshape - Rot, Reciproc - Rot), (One shape Reciproc, Reciproc - Rec); (p >.05). Least cracks were seen in canals instrumented with Pro Taper Next files both in rotary and reciprocating motion. Full sequence rotary systems showed less cracks than single file systems and full sequence rotary systems showed less cracks in reciprocating motion than in rotary motion.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-02
... Window Division, Including On-Site Leased Workers of Nicolet Staffing, Hawkins, WI; Notice of Negative... imports of wood- and aluminum- clad windows and patio doors did not contribute to worker group separations... of wood- and aluminum-clad windows and patio doors during 2007, 2008, January through April 2008, and...
Yanagawa, Masahiro; Kusumoto, Masahiko; Johkoh, Takeshi; Noguchi, Masayuki; Minami, Yuko; Sakai, Fumikazu; Asamura, Hisao; Tomiyama, Noriyuki
2018-05-01
Measuring the size of invasiveness on computed tomography (CT) for the T descriptor size was deemed important in the 8th edition of the TNM lung cancer classification. We aimed to correlate the maximal dimensions of the solid portions using both lung and mediastinal window settings on CT imaging with the pathologic invasiveness (> 0.5 cm) in lung adenocarcinoma patients. The study population consisted of 378 patients with a histologic diagnosis of adenocarcinoma in situ (AIS), minimally invasive adenocarcinoma (MIA), invasive adenocarcinoma (IVA)-lepidic, IVA-acinar and/or IVA-papillary, and IVA-micropapillary and/or solid adenocarcinoma. A panel of 15 radiologists was divided into 2 groups (group A, 9 radiologists; and group B, 6 radiologists). The 2 groups independently measured the maximal and perpendicular dimensions of the solid components and entire tumors on the lung and mediastinal window settings. The solid proportion of nodule was calculated by dividing the solid portion size (lung and mediastinal window settings) by the nodule size (lung window setting). The maximal dimensions of the invasive focus were measured on the corresponding pathologic specimens by 2 pathologists. The solid proportion was larger in the following descending order: IVA-micropapillary and/or solid, IVA-acinar and/or papillary, IVA-lepidic, MIA, and AIS. For both groups A and B, a solid portion > 0.8 cm in the lung window setting or > 0.6 cm in the mediastinal window setting on CT was a significant indicator of pathologic invasiveness > 0.5 cm (P < .001; receiver operating characteristic analysis using Youden's index). A solid portion > 0.8 cm on the lung window setting or solid portion > 0.6 cm on the mediastinal window setting on CT predicts for histopathologic invasiveness to differentiate IVA from MIA and AIS. Copyright © 2017 The Author(s). Published by Elsevier Inc. All rights reserved.
Vorster, Martin; van der Vyver, Peet J; Paleker, Farzana
2018-05-01
The aim of this study was to compare the glide path preparation times of stainless steel hand files, PathFiles (Dentsply Sirona, Ballaigues, Switzerland), and the WaveOne Gold Glider (Dentsply Sirona). The preparation times for final root canal shaping with the Primary WaveOne Gold instrument in extracted human molar teeth with and without prior glide path preparation were also recorded and compared. Mesiobuccal canals of 60 extracted human mandibular molars (curvature angles between 25° and 35° and radii <10 mm) were selected and randomly divided into 4 groups with 15 canals each. Canals were negotiated to patency with a #8 K-file. Canal preparations were performed by a single operator using precurved #10-15-20 stainless steel manual K-files (the K-file group), a #10 stainless steel manual K-file followed by PathFiles #1-3 (the PathFile group), a #10 stainless steel manual K-file followed by WaveOne Gold Glider (the WaveOne Gold Glider group), or no further glide path preparation. Final canal preparation of all 60 canals was performed with the Primary WaveOne Gold instrument. Glide path and final preparation times were recorded. Glide path enlargement was statistically significantly fastest in the WaveOne Gold Glider group (19.7 ± 5.6 seconds) followed by the PathFile group (41.0 ± 6.8 seconds) and then the K-file group (81.2 ± 26.3 seconds) using analysis of variance (ANOVA) and Kruskal-Wallis tests (P < .0001). No statistically significant difference in the mean final preparation times was found among the WaveOne Gold Glider (23.1 ± 6.0 seconds), PathFile (24.4 ± 4.9 seconds), and K-file groups (27.2 ± 9.5 seconds). All 3 groups were statistically significantly faster than the no glide path preparation group (35.4 ± 10.2 seconds) using ANOVA (P = .0004) and Kruskal-Wallis tests (P = .0010). Preparation time with the Primary WaveOne Gold file was statistically significantly reduced when the file was used in combination with any of the glide path preparation techniques. The WaveOne Gold Glider performed statistically significantly faster in glide path preparation time than the other glide path preparation techniques. Copyright © 2018 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
User's manual for the Gaussian windows program
NASA Technical Reports Server (NTRS)
Jaeckel, Louis A.
1992-01-01
'Gaussian Windows' is a method for exploring a set of multivariate data, in order to estimate the shape of the underlying density function. The method can be used to find and describe structural features in the data. The method is described in two earlier papers. I assume that the reader has access to both of these papers, so I will not repeat material from them. The program described herein is written in BASIC and it runs on an IBM PC or PS/2 with the DOS 3.3 operating system. Although the program is slow and has limited memory space, it is adequate for experimenting with the method. Since it is written in BASIC, it is relatively easy to modify. The program and some related files are available on a 3-inch diskette. A listing of the program is also available. This user's manual explains the use of the program. First, it gives a brief tutorial, illustrating some of the program's features with a set of artificial data. Then, it describes the results displayed after the program does a Gaussian window, and it explains each of the items on the various menus.
Comparison between rotary and manual instrumentation in primary teeth.
Crespo, S; Cortes, O; Garcia, C; Perez, L
2008-01-01
The aim of this study was to compare the efficiency in both, preparation time and root canal shape, when using the Nickel Titanium (Ni-Ti) rotary and K-Files hand instrumentation on root canal preparation of single rooted primary teeth. Sixty single rooted primary teeth were selected and divided into two equal groups: Group (I) 30 teeth instrumented with manual K-files and group (II) 30 teeth instrumented with Ni-Ti rotary files (ProFile 0.04). Instrumentation times were calculated and root canal impressions were taken with light bodied silicone in order to evaluate the shape. The data was analyzed with SPSS program using the t-test and the Chi-square test to compare their means. The preparation time with group (I) K-files was significantly higher than in group (II) rotary files (ProFile 0.04), with a p= .005. The ProFile system showed a significantly more favorable canal taper when compared to the K-files system (P= .002). The use of rotary files in primary teeth has several advantages when compared with manual K files: the efficiency in both, preparation time and root canal shape. 1. A decreased working time, that helps maintain patient cooperation by diminishing the potential for tiredness. 2. The shape of the root canal is more conical, favoring a higher quality of the root canal filling, and increasing clinical success.
Wear of the Primary WaveOne single file when shaping vestibular root canals of first maxillary molar
Borie, Eduardo; Betancourt, Pablo; Aracena, Angella; Guzmán, Mario
2017-01-01
Background It is very important for a clinician to know the increased wear of mechanized files when establishing endodontic therapy. The aim of this study was to check the wear of the Primary WaveOne file upon shaping two, four and six maxillary molar vestibular canals. Material and Methods The deterioration of 40 files, divided into four groups, was evaluated microscopically: group 1, control (unused); group 2, two canals; group 3, four canals; and group 4, six canals. After instrumentation, the files were embedded in resin and sectioned at their apical third into three equal parts. To analyze the wear of edges in the different sections, AutoCAD software was used and analysis of variance (ANOVA) was then performed to compare the mean rake angles. Results The files with two and four uses showed slight wear, whereas those with six applications showed significant wear (p<0.05). Conclusions Primary WaveOne files can be used in up to four root canals without their edges losing effectiveness. Key words:Files wear, reciprocating motion, shaping capacity, WaveOne. PMID:28298976
Aracena, Daniel; Borie, Eduardo; Betancourt, Pablo; Aracena, Angella; Guzmán, Mario
2017-03-01
It is very important for a clinician to know the increased wear of mechanized files when establishing endodontic therapy. The aim of this study was to check the wear of the Primary WaveOne file upon shaping two, four and six maxillary molar vestibular canals. The deterioration of 40 files, divided into four groups, was evaluated microscopically: group 1, control (unused); group 2, two canals; group 3, four canals; and group 4, six canals. After instrumentation, the files were embedded in resin and sectioned at their apical third into three equal parts. To analyze the wear of edges in the different sections, AutoCAD software was used and analysis of variance (ANOVA) was then performed to compare the mean rake angles. The files with two and four uses showed slight wear, whereas those with six applications showed significant wear ( p <0.05). Primary WaveOne files can be used in up to four root canals without their edges losing effectiveness. Key words: Files wear, reciprocating motion, shaping capacity, WaveOne.
System Integration Issues in Digital Photogrammetric Mapping
1992-01-01
elevation models, and/or rectified imagery/ orthophotos . Imagery exported from the DSPW can be either in a tiled image format or standard raster format...data. In the near future, correlation using "window shaping" operations along with an iterative orthophoto refinements methodology (Norvelle, 1992) is...components of TIES. The IDS passes tiled image data and ASCII header data to the DSPW. The tiled image file contains only image data. The ASCII header
pick_xwell, a program for interactive picking of crosswell seismic and radar data
Ellefsen, K.J.
1999-01-01
travel times can be plotted on the computer screen or printed to a file in postscript format. The program is written in the IDL programming language, and it is executed, in command-line mode, within the IDL program. The IDL program must be run from an X-window terminal that is connected to a computer with the Unix operating system. The data must be in the SU format.
Integration of CW / Radionucleotide Detection Systems to the Fido XT Explosives Detector
2008-07-31
explosives detected by the Fido XT. Additionally, a platform for centralized storage and processing of Fido XT data files collected in house, targeted...fused silica glass wool (obtained from Restek). The fluorescent signal was easily washed out of the flow cell by a nominal amount of buffer...detector with supporting NRE was processed . The Interceptor components were configured to operate under a Windows CE processor environment, and to
MVC for Content Management on the Cloud
2011-09-01
Windows, Linux , MacOS, PalmOS and other customized ones (Qiu). Figure 20 illustrates implementation of MVC architecture. Qiu examines a “universal...Listing of Unzipped Text Document (From O’Reilly & Associates, Inc, 2005) Figure 37 shows the results of unzipping this file in Linux . The contents of the...ODF Adoption TC, and the ODF Alliance include members from Adobe, BBC, Bristol City Council, Bull, Corel, EDS, EMC, GNOME, IBM, Intel, KDE , MySQL
Digital Forensics Research: The Next 10 Years
2010-01-01
techniques were developed primarily for data recovery. For example, Wood et al. relate a story about two local data recovery experts working for 70 h to...recover the only copy of a highly fragmented database file inadvertently erased by a careless researcher (pp.123e124 Wood et al., 1987). By the late 1980s... Apple , Blackberry, Windows Mobile, Symbian), more than a dozen “proprietary” systems, and more than 100,000 downloadable applications. There are
Pilot Fullerton reviews FDF and TAGS printout on forward flight deck
1982-03-30
STS003-23-180 (22-30 March 1982) --- Astronaut Gordon Fullerton, STS-3 pilot, wearing communications kit assembly (ASSY) mini-headset (HDST), reviews flight data file (FDF) checklist and text and graphics system (TAGS) printout (ticker tape) while in pilots ejection seat (S2). Pilot station control panels F4, F7, F8, O3, window shade, and portable oxygen system (POS) assy appear in view. Photo credit: NASA
2007-09-01
before McNair, Wills, Stevens, and Maxfield arrived. Finding no way to open one of the renovated windows, Petrovich had picked up a nearby laser printer...force" Most of the columns in the collapsed zone had been destroyed and some of the remaining ones were " stripped and bowed, retaining little structural...Desks and filing cabinets were reduced to scrap metal. Asbestos lay exposed and lead paint peeled off walls. A layer of black soot cov- ered virtually
Ensuring a C2 Level of Trust and Interoperability in a Networked Windows NT Environment
1996-09-01
addition, it should be noted that the device drivers, microkernel , memory manager, and Hardware Abstraction Layer are all hardware dependent. a. The...Executive The executive is further divided into three conceptual layers which are referred to as-the Hardware Abstraction Layer (HAL), the Microkernel , and...Subsystem Executive Subsystems Manager I/O Manager Cache Manager File Systems Microkernel Device Driver Hardware Abstraction Layer F HARDWARE Figure 3
Entity Resolution Workflow Installation Process and User Guide
2013-07-01
Program Files\\PostgreSQL\\9.1\\data superuser ( postgres ), service account ( postgres ) password : "password" Port #: 5432 Add an environment variable...in this report. • Run the script found in <GG_HOME>\\ globalgraph-dist-1.4.6-final\\schema- ddl\\postgresSetup.bat. This script will set up Postgres ...Username: postgres DB Admin PWD: password GlobalGraph App User: gguser GlobalGraph App PWD: password • Restart the Postgres service using the Windows
cljam: a library for handling DNA sequence alignment/map (SAM) with parallel processing.
Takeuchi, Toshiki; Yamada, Atsuo; Aoki, Takashi; Nishimura, Kunihiro
2016-01-01
Next-generation sequencing can determine DNA bases and the results of sequence alignments are generally stored in files in the Sequence Alignment/Map (SAM) format and the compressed binary version (BAM) of it. SAMtools is a typical tool for dealing with files in the SAM/BAM format. SAMtools has various functions, including detection of variants, visualization of alignments, indexing, extraction of parts of the data and loci, and conversion of file formats. It is written in C and can execute fast. However, SAMtools requires an additional implementation to be used in parallel with, for example, OpenMP (Open Multi-Processing) libraries. For the accumulation of next-generation sequencing data, a simple parallelization program, which can support cloud and PC cluster environments, is required. We have developed cljam using the Clojure programming language, which simplifies parallel programming, to handle SAM/BAM data. Cljam can run in a Java runtime environment (e.g., Windows, Linux, Mac OS X) with Clojure. Cljam can process and analyze SAM/BAM files in parallel and at high speed. The execution time with cljam is almost the same as with SAMtools. The cljam code is written in Clojure and has fewer lines than other similar tools.
Co-PylotDB - A Python-Based Single-Window User Interface for Transmitting Information to a Database
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barnette, Daniel W.
2012-01-05
Co-PylotDB, written completely in Python, provides a user interface (UI) with which to select user and data file(s), directories, and file content, and provide or capture various other information for sending data collected from running any computer program to a pre-formatted database table for persistent storage. The interface allows the user to select input, output, make, source, executable, and qsub files. It also provides fields for specifying the machine name on which the software was run, capturing compile and execution lines, and listing relevant user comments. Data automatically captured by Co-PylotDB and sent to the database are user, current directory,more » local hostname, current date, and time of send. The UI provides fields for logging into a local or remote database server, specifying a database and a table, and sending the information to the selected database table. If a server is not available, the UI provides for saving the command that would have saved the information to a database table for either later submission or for sending via email to a collaborator who has access to the desired database.« less
NASA One-Dimensional Combustor Simulation--User Manual for S1D_ML
NASA Technical Reports Server (NTRS)
Stueber, Thomas J.; Paxson, Daniel E.
2014-01-01
The work presented in this paper is to promote research leading to a closed-loop control system to actively suppress thermo-acoustic instabilities. To serve as a model for such a closed-loop control system, a one-dimensional combustor simulation composed using MATLAB software tools has been written. This MATLAB based process is similar to a precursor one-dimensional combustor simulation that was formatted as FORTRAN 77 source code. The previous simulation process requires modification to the FORTRAN 77 source code, compiling, and linking when creating a new combustor simulation executable file. The MATLAB based simulation does not require making changes to the source code, recompiling, or linking. Furthermore, the MATLAB based simulation can be run from script files within the MATLAB environment or with a compiled copy of the executable file running in the Command Prompt window without requiring a licensed copy of MATLAB. This report presents a general simulation overview. Details regarding how to setup and initiate a simulation are also presented. Finally, the post-processing section describes the two types of files created while running the simulation and it also includes simulation results for a default simulation included with the source code.
Koc, Murat; Dalgic, Abdullah; Ozuer, Mehmet Ziya
2016-03-01
We conducted an animal experiment to investigate the effects of mechanical trauma to the round window with the placement of a model electrode inserted into the scala tympani on the cochlear reserve, and to determine the efficacy of topical steroids in preventing hearing loss in such a situation. Our subjects included 21 male Wistar albino rats that were assigned into three groups of 7 each. In all three groups, an initial mechanical injury to the round window was created. At that point, group 1 received no further treatment, group 2 received a dexamethasone injection into the cochlea, and group 3 underwent implantation of a multichannel cochlear implant guide followed by dexamethasone administration. After a few minutes, the round window opening was obliterated with muscle, and the incision was sutured with 4-0 Vicryl Rapide polyglactin in all 3 groups. Distortion-product otoacoustic emissions were obtained before and immediately after the surgical injury, and again on postoperative day 7. Mean signal/noise ratios (S/Ns) obtained at 2, 3, and 4 kHz were calculated, and datasets were compared with nonparametric statistical tests. We found that the early postoperative mean S/N values were significantly lower than the preoperative values in groups 1 and 2, but there was no difference between the mean preoperative values and those obtained on postoperative day 7 in those two groups. In group 3, there were statistically significant differences among the mean preoperative, early postoperative, and postoperative day 7 S/N values. We observed that an electrode insertion into the cochlea via the round window subsequent to mechanical trauma seemed to cause a progressive hearing loss. Therefore, we conclude that special care must be taken to avoid injury to the round window membrane during placement of a cochlear implant electrode, as well as during surgery for chronic otitis media.
Topcu, K Meltem; Karatas, Ertugrul; Ozsu, Damla; Ersoy, Ibrahim
2014-07-01
The aim of this study was to compare the canal debridement capabilities of three single file systems, ProTaper, and K-files in oval-shaped canals. Seventy-five extracted human mandibular central incisors with oval-shaped root canals were selected. A radiopaque contrast medium (Metapex; Meta Biomed Co. Ltd., Chungcheongbuk-do, Korea) was introduced into the canal systems and the self-adjusting file (SAF), WaveOne, Reciproc, ProTaper, and K-files were used for the instrumentation of the canals. The percentage of removed contrast medium was calculated using pre- and post-operative radiographs. An overall comparison between the groups revealed that the hand file (HF) and SAF groups presented the lowest percentage of removed contrast medium, whereas the WaveOne group showed the highest percentage (P < 0.001). The ProTaper group removed more contrast medium than the SAF and HF groups (P < 0.05). None of the instruments was able to remove the contrast medium completely. WaveOne performed significantly better than other groups.
Topcu, K. Meltem; Karatas, Ertugrul; Ozsu, Damla; Ersoy, Ibrahim
2014-01-01
Objectives: The aim of this study was to compare the canal debridement capabilities of three single file systems, ProTaper, and K-files in oval-shaped canals. Materials and Methods: Seventy-five extracted human mandibular central incisors with oval-shaped root canals were selected. A radiopaque contrast medium (Metapex; Meta Biomed Co. Ltd., Chungcheongbuk-do, Korea) was introduced into the canal systems and the self-adjusting file (SAF), WaveOne, Reciproc, ProTaper, and K-files were used for the instrumentation of the canals. The percentage of removed contrast medium was calculated using pre- and post-operative radiographs. Results: An overall comparison between the groups revealed that the hand file (HF) and SAF groups presented the lowest percentage of removed contrast medium, whereas the WaveOne group showed the highest percentage (P < 0.001). The ProTaper group removed more contrast medium than the SAF and HF groups (P < 0.05). Conclusions: None of the instruments was able to remove the contrast medium completely. WaveOne performed significantly better than other groups. PMID:25202211
Wang, Jing; Gao, Yan; Wang, Qing-shan; Zhang, Yan; Rong, Li; Wang, Jiu
2014-08-01
To evaluate the cleaning effect of the C-shaped canal treated by manual K file and ProTaper rotary endodontic file combined with ultrasonic cleaning, and find a better cleaning program for the C-shaped root canal. Fifty mandibular second molars were randomly divided into 5 groups: K file group, K file+ultrasonic rinsing group, ProTaper group, ProTaper+ultrasonic rinsing group and the control group. After initial shaping and cleaning, the mandibular second molars were soaked in formalin and stained. Under microscopy, the cleaning rate of necrotic tissue and cutting area were observed and analyzed. The data was processed with SPSS 17.0 software package. The cleaning rates of the treated groups were significantly higher than that of the control group (P<0.05); In each treatment group, the cleaning rate of the apex was significantly lower than that of the crown and central part (P<0.05); The cutting score of ProTaper+ultrasonic cleaning group was lower than that of the other treatment groups; The cutting score of the K file+ultrasonic rinsing group was significantly lower than that of the K file group (P<0.05); The cutting score and cleaning rate were negatively correlated (r=-0.712, P=0.000 ), the linear regression was the cleaning rate =98.325-4.325 × wall cutting score (R=0.454, P<0.05). In the process of shaping and cleaning of C-shaped canal, it is recommended that the ProTaper nickel-titanium rotary endodontic file should be chosen to clean the top of the taproot pipe and combined with ultrasonic rinsing to achieve better results.
Chandrasekar; Ebenezar, A V Rajesh; Kumar, Mohan; Sivakumar, A
2014-11-01
The aim of this study was to evaluate the efficacy of Protaper retreatment files in comparison with RaCe, K3 and H-files for removal of gutta-percha and apically extruded debris using volumetric analysis. Forty extracted single rooted maxillary incisor teeth with straight canals and mature apices were selected for the study. After access cavity preparation, apical patency was confirmed with a size 10 K-file extending 1mm beyond the point at which it was first visible at the apical end. Working lengths were determined with the use of size 15 K-file. The canals were prepared in a step-back technique and the master apical file was size 30 for all teeth. 3% sodium hypochlorite was used as an irrigant after each instrumentation. Before final rinse, size 20 K-file was passed 1mm beyond the apex to remove any dentinal shaving plugs and maintain the apical patency. Then the canals were dried with paper points. The root canal was filled using standard gutta-percha points and zinc oxide eugenol sealer under lateral condensation technique. The teeth were then randomly divided into four groups of ten teeth each based on the instrument used for gutta percha removal. All the rotary instruments used in this study were rotated at 300rpm. The instruments used were: Group 1 - RaCe Files, Group 2 - ProTaper retreatment Files, Group 3 - K3 Files and Group 4 - H Files. The volume of the obturating material was calculated before and after removal using volumetric analysis with spiral CT. The removal efficacy with each instrument was calculated and statistically analysed. The results of the study show that the ProTaper retreatment files (Group 2) (97.4%) showed the highest efficiency in the removal of obturating material, which was followed by RaCe (95.74%), K3 (92.86%) and H files (90.14%) with the efficiency in the decreasing order. Similarly the mean apical extrusion in H files (0.000 ± 0.002) was significantly lower than all the rotary instruments. However, the difference among the rotary files were not statistically significant (p>0.05). ProTaper retreatment files show significant difference over other groups in removal of obturating material and can be the system of choice in endodontic retreatment procedures.
SutraPrep, a pre-processor for SUTRA, a model for ground-water flow with solute or energy transport
Provost, Alden M.
2002-01-01
SutraPrep facilitates the creation of three-dimensional (3D) input datasets for the USGS ground-water flow and transport model SUTRA Version 2D3D.1. It is most useful for applications in which the geometry of the 3D model domain and the spatial distribution of physical properties and boundary conditions is relatively simple. SutraPrep can be used to create a SUTRA main input (?.inp?) file, an initial conditions (?.ics?) file, and a 3D plot of the finite-element mesh in Virtual Reality Modeling Language (VRML) format. Input and output are text-based. The code can be run on any platform that has a standard FORTRAN-90 compiler. Executable code is available for Microsoft Windows.
Comparison of Geometric Design of a Brand of Stainless Steel K-Files: An In Vitro Study.
Saeedullah, Maryam; Husain, Syed Wilayat
2018-04-01
The purpose of this experimental study was to determine the diametric variations of a brand of handheld stainless-steel K-files, acquired from different countries, in accordance with the available standards. 20 Mani stainless-steel K-files of identical size (ISO#25) were acquired from Pakistan and were designated as Group A while 20 Mani K-files were purchased from London, UK and designated as Group B. Files were assessed using profile projector Nikon B 24V. Data was statistically compared with ISO 3630:1 and ADA 101 by one sample T test. Significant difference was found between Groups A and B. Average discrepancy of Group A fell within the tolerance limit while that of Group B exceeded the limit. Findings in this study call attention towards adherence to the dimensional standards of stainless-steel endodontic files.
Wilson, Ander; Chiu, Yueh-Hsiu Mathilda; Hsu, Hsiao-Hsien Leon; Wright, Robert O; Wright, Rosalind J; Coull, Brent A
2017-07-01
Epidemiological research supports an association between maternal exposure to air pollution during pregnancy and adverse children's health outcomes. Advances in exposure assessment and statistics allow for estimation of both critical windows of vulnerability and exposure effect heterogeneity. Simultaneous estimation of windows of vulnerability and effect heterogeneity can be accomplished by fitting a distributed lag model (DLM) stratified by subgroup. However, this can provide an incomplete picture of how effects vary across subgroups because it does not allow for subgroups to have the same window but different within-window effects or to have different windows but the same within-window effect. Because the timing of some developmental processes are common across subpopulations of infants while for others the timing differs across subgroups, both scenarios are important to consider when evaluating health risks of prenatal exposures. We propose a new approach that partitions the DLM into a constrained functional predictor that estimates windows of vulnerability and a scalar effect representing the within-window effect directly. The proposed method allows for heterogeneity in only the window, only the within-window effect, or both. In a simulation study we show that a model assuming a shared component across groups results in lower bias and mean squared error for the estimated windows and effects when that component is in fact constant across groups. We apply the proposed method to estimate windows of vulnerability in the association between prenatal exposures to fine particulate matter and each of birth weight and asthma incidence, and estimate how these associations vary by sex and maternal obesity status in a Boston-area prospective pre-birth cohort study. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Katge, Farhin; Chimata, Vamsi Krishna; Poojari, Manohar; Shetty, Shilpa; Rusawat, Bhavesh
2016-01-01
The aim of this study was to compare the cleaning efficacy and instrumentation time between manual Hedstrom files (H-files) and rotary Mtwo files in primary molar root canals. A total of 90 primary root canals were selected using standardized radiographs. The canals were injected with India ink with 30 gauge insulin syringe and divided into three groups. Group I-30 root canals instrumented with H-files, group II-30 root canals instrumented with Mtwo files, and group III-control group in which no canal instrumentation was done. The teeth were cleared in various solutions and then observed under a stereomicroscope. No significant difference was seen in cleaning efficacy between H-files and Mtwo files in coronal, middle, and apical thirds of the root canal. The instrumentation time recorded for H-files (3.41 ± 0.38 minutes) was significantly less than that of Mtwo files (4.81 ± 0.52). Although there was no significant difference in cleaning capacity, further studies should be carried out using the single file systems. How to cite this article: Katge F, Chimata VK, Poojari M, Shetty S, Rusawat B. Comparison of cleaning Efficacy and Instrumentation Time between Rotary and Manual Instrumentation Techniques in Primary Teeth: An in vitro Study. Int J Clin Pediatr Dent 2016;9(2):124-127.
Development of EnergyPlus Utility to Batch Simulate Building Energy Performance on a National Scale
DOE Office of Scientific and Technical Information (OSTI.GOV)
Valencia, Jayson F.; Dirks, James A.
2008-08-29
EnergyPlus is a simulation program that requires a large number of details to fully define and model a building. Hundreds or even thousands of lines in a text file are needed to run the EnergyPlus simulation depending on the size of the building. To manually create these files is a time consuming process that would not be practical when trying to create input files for thousands of buildings needed to simulate national building energy performance. To streamline the process needed to create the input files for EnergyPlus, two methods were created to work in conjunction with the National Renewable Energymore » Laboratory (NREL) Preprocessor; this reduced the hundreds of inputs needed to define a building in EnergyPlus to a small set of high-level parameters. The first method uses Java routines to perform all of the preprocessing on a Windows machine while the second method carries out all of the preprocessing on the Linux cluster by using an in-house built utility called Generalized Parametrics (GPARM). A comma delimited (CSV) input file is created to define the high-level parameters for any number of buildings. Each method then takes this CSV file and uses the data entered for each parameter to populate an extensible markup language (XML) file used by the NREL Preprocessor to automatically prepare EnergyPlus input data files (idf) using automatic building routines and macro templates. Using a Linux utility called “make”, the idf files can then be automatically run through the Linux cluster and the desired data from each building can be aggregated into one table to be analyzed. Creating a large number of EnergyPlus input files results in the ability to batch simulate building energy performance and scale the result to national energy consumption estimates.« less
Iconic Meaning in Music: An Event-Related Potential Study.
Cai, Liman; Huang, Ping; Luo, Qiuling; Huang, Hong; Mo, Lei
2015-01-01
Although there has been extensive research on the processing of the emotional meaning of music, little is known about other aspects of listeners' experience of music. The present study investigated the neural correlates of the iconic meaning of music. Event-related potentials (ERP) were recorded while a group of 20 music majors and a group of 20 non-music majors performed a lexical decision task in the context of implicit musical iconic meaning priming. ERP analysis revealed a significant N400 effect of congruency in time window 260-510 ms following the onset of the target word only in the group of music majors. Time-course analysis using 50 ms windows indicated significant N400 effects both within the time window 410-460 ms and 460-510 ms for music majors, whereas only a partial N400 effect during time window 410-460 ms was observed for non-music majors. There was also a trend for the N400 effects in the music major group to be stronger than those in the non-major group in the sub-windows of 310-360 ms and 410-460 ms. Especially in the sub-window of 410-460 ms, the topographical map of the difference waveforms between congruent and incongruent conditions revealed different N400 distribution between groups; the effect was concentrated in bilateral frontal areas for music majors, but in central-parietal areas for non-music majors. These results imply probable neural mechanism differences underlying automatic iconic meaning priming of music. Our findings suggest that processing of the iconic meaning of music can be accomplished automatically and that musical training may facilitate the understanding of the iconic meaning of music.
Iconic Meaning in Music: An Event-Related Potential Study
Luo, Qiuling; Huang, Hong; Mo, Lei
2015-01-01
Although there has been extensive research on the processing of the emotional meaning of music, little is known about other aspects of listeners’ experience of music. The present study investigated the neural correlates of the iconic meaning of music. Event-related potentials (ERP) were recorded while a group of 20 music majors and a group of 20 non-music majors performed a lexical decision task in the context of implicit musical iconic meaning priming. ERP analysis revealed a significant N400 effect of congruency in time window 260-510 ms following the onset of the target word only in the group of music majors. Time-course analysis using 50 ms windows indicated significant N400 effects both within the time window 410-460 ms and 460-510 ms for music majors, whereas only a partial N400 effect during time window 410-460 ms was observed for non-music majors. There was also a trend for the N400 effects in the music major group to be stronger than those in the non-major group in the sub-windows of 310-360ms and 410-460ms. Especially in the sub-window of 410-460 ms, the topographical map of the difference waveforms between congruent and incongruent conditions revealed different N400 distribution between groups; the effect was concentrated in bilateral frontal areas for music majors, but in central-parietal areas for non-music majors. These results imply probable neural mechanism differences underlying automatic iconic meaning priming of music. Our findings suggest that processing of the iconic meaning of music can be accomplished automatically and that musical training may facilitate the understanding of the iconic meaning of music. PMID:26161561
75 FR 51258 - Combined Notice of Filings #1
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-19
... Group Maine, LLC submits tariff filing per 35.12: Constellation Energy Commodities Group Maine Baseline... 35.12: Luminant Energy Company LLC MBR Baseline to be effective 8/11/ 2010. Filed Date: 08/11/2010... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission Combined Notice of Filings 1 August 11...
Cyclic fatigue of three types of rotary nickel-titanium files in a dynamic model.
Yao, James H; Schwartz, Scott A; Beeson, Thomas J
2006-01-01
The cyclic fatigue resistance of three types of nickel-titanium rotary files was compared in a model using reciprocating axial movement. The influence of file size and taper was also investigated and fracture patterns were examined under SEM. The 10 experimental groups consisted of ProFiles, K3s, and RaCe files, size 25 in .04 and .06 tapers, as well as ProFiles and K3s, size 40 in .04 and .06 tapers. Each file was rotated freely at 300 rpm inside a stainless steel tube with a 60 degree and 5 mm radius of curvature. A continuous 3 mm oscillating axial motion was applied at 1 cycle per second by attaching an electric dental handpiece to the most inferior load cell of an Instron machine using a custom-made jig. The number of rotations to failure was determined and analyzed using analysis of variance and Tukey's post hoc tests. Overall, K3 25/.04 files were significantly more resistant to cyclic fatigue compared to any other group in this study. In the 25/.04 category, K3s were significantly more resistant to failure than ProFiles and RaCe files. Also in the same category, ProFiles significantly outlasted RaCe files. In the 25/.06 group, K3s and ProFiles were significantly more resistant to failure than RaCe files, but K3s were not significantly different than ProFiles. In the 40/.04 and 40/.06 groups, K3s were significantly more resistant to cyclic fatigue than ProFiles. SEM observations demonstrated mostly a ductile mode of fracture. The results suggest that different cross-sectional designs, diameters, and tapers all contribute to a nickel-titanium instrument's vulnerability to cyclic failure.
Interactive real-time media streaming with reliable communication
NASA Astrophysics Data System (ADS)
Pan, Xunyu; Free, Kevin M.
2014-02-01
Streaming media is a recent technique for delivering multimedia information from a source provider to an end- user over the Internet. The major advantage of this technique is that the media player can start playing a multimedia file even before the entire file is transmitted. Most streaming media applications are currently implemented based on the client-server architecture, where a server system hosts the media file and a client system connects to this server system to download the file. Although the client-server architecture is successful in many situations, it may not be ideal to rely on such a system to provide the streaming service as users may be required to register an account using personal information in order to use the service. This is troublesome if a user wishes to watch a movie simultaneously while interacting with a friend in another part of the world over the Internet. In this paper, we describe a new real-time media streaming application implemented on a peer-to-peer (P2P) architecture in order to overcome these challenges within a mobile environment. When using the peer-to-peer architecture, streaming media is shared directly between end-users, called peers, with minimal or no reliance on a dedicated server. Based on the proposed software pɛvμa (pronounced [revma]), named for the Greek word meaning stream, we can host a media file on any computer and directly stream it to a connected partner. To accomplish this, pɛvμa utilizes the Microsoft .NET Framework and Windows Presentation Framework, which are widely available on various types of windows-compatible personal computers and mobile devices. With specially designed multi-threaded algorithms, the application can stream HD video at speeds upwards of 20 Mbps using the User Datagram Protocol (UDP). Streaming and playback are handled using synchronized threads that communicate with one another once a connection is established. Alteration of playback, such as pausing playback or tracking to a different spot in the media file, will be reflected in all media streams. These techniques are designed to allow users at different locations to simultaneously view a full length HD video and interactively control the media streaming session. To create a sustainable media stream with high quality, our system supports UDP packet loss recovery at high transmission speed using custom File- Buffers. Traditional real-time streaming protocols such as Real-time Transport Protocol/RTP Control Protocol (RTP/RTCP) provide no such error recovery mechanism. Finally, the system also features an Instant Messenger that allows users to perform social interactions with one another while they enjoy a media file. The ultimate goal of the application is to offer users a hassle free way to watch a media file over long distances without having to upload any personal information into a third party database. Moreover, the users can communicate with each other and stream media directly from one mobile device to another while maintaining an independence from traditional sign up required by most streaming services.
Gonzalez-Ramella, O; Ortiz-Lazareno, P C; Jiménez-López, X; Gallegos-Castorena, S; Hernández-Flores, G; Medina-Barajas, F; Meza-Arroyo, J; Jave-Suárez, L F; Lerma-Díaz, J M; Sánchez-Zubieta, F; Bravo-Cuellar, A
2016-04-01
Pentoxifylline (PTX) has been shown to increase chemotherapy-induced apoptosis. A clinical trial was developed to evaluate the effect of the addition of PTX to the induction steroid window phase in children with acute lymphoblastic leukemia (ALL). Thirty-two children were enrolled on this study. Children with a new diagnosis of ALL were randomly assigned to receive prednisone (PRD) 40 mg/m(2)/day only during the 7-day treatment pre-phase (PRD group, 11 patients) or to receive PRD with PTX (10 mg/kg/day) (PTX group, 11 patients); the control group included children with normal bone marrow (10 patients). Bone marrow aspiration (BMA) was performed at diagnosis (day -7) in all groups, and at day 0 (end of PRD window) for patients with ALL (PRD and PTX groups). Apoptosis was evaluated by flow cytometry (FC) using Annexin V-fluorescein isothiocyanate (FITC)/propidium iodide (PI) stains. Statistical analysis was performed using the Mann-Whitney U test. Apoptotic index at day -7 was similar in all groups. However, at day 0 post-treatment, apoptosis was significantly higher in the PTX group than in the PRD group (p < 0.001). There were no serious adverse effects associated with PTX. PTX potentiates blast apoptosis induced by PRD in children with ALL during steroid window phase.
Plasma Interactions With Spacecraft (I)
2009-04-01
with the Windows, Red hat LINUX, and MacOS X environments. We wrote N2kScriptRunner, a C++ code that runs a Nascap-2k script outside of the Java ...console-based and with a Java interface), a stand alone program that reads and writes Nascap-2k database files. This program has proved invaluable...surface currents for DSX and prototyped it in Java . A description of the algorithm and the prototype implementation is in Section 3. 1.5. DSX
Data Link Test and Analysis System/ATCRBS Transponder Test System
1990-05-01
cc pcinit() pcinit.cc plotdato( plotdat. cc plotmsgo( sumscrn *cc plotqueo( sumscrn. cc pmsg () pmsg.cc pr_head() prhead.cc Virt init() print.cc pw...The code data from the Decode Status word from hardware. 2 a data-> wind nm - The reply window that this data came from. mvarms) NAME mparms - Modify...character is entered. m5sg() NAME pmsg - Print error message. Source file - pmsg.cc. FUNCTION CALL pmsg (ecode, str) int ecode; /* Error code */ char
Forensic Analysis of Window’s(Registered) Virtual Memory Incorporating the System’s Page-File
2008-12-01
Management and Budget, Paperwork Reduction Project (0704-0188) Washington DC 20503. 1. AGENCY USE ONLY (Leave blank) 2. REPORT DATE December...data in a meaningful way. One reason for this is how memory is managed by the operating system. Data belonging to one process can be distributed...way. One reason for this is how memory is managed by the operating system. Data belonging to one process can be distributed arbitrarily across
ImageJ: Image processing and analysis in Java
NASA Astrophysics Data System (ADS)
Rasband, W. S.
2012-06-01
ImageJ is a public domain Java image processing program inspired by NIH Image. It can display, edit, analyze, process, save and print 8-bit, 16-bit and 32-bit images. It can read many image formats including TIFF, GIF, JPEG, BMP, DICOM, FITS and "raw". It supports "stacks", a series of images that share a single window. It is multithreaded, so time-consuming operations such as image file reading can be performed in parallel with other operations.
A CMake-Based Cross Platform Build System for Tcl/Tk
2011-11-01
expressing the logic for generating user-installable packages of the finished package. While specific com- pilation instructions are typically unique to each...Windows com- pilation . This presented a difficulty for the BRL- CAD project in that neither of these systems inte- grated well with BRL-CAD’s own build...build files. 2. Implement enough of the Tcl/Tk–specific com- pilation macro logic in CMake to support build- 1Twylite’s Coffee project uses CMake to
CloudMC: a cloud computing application for Monte Carlo simulation.
Miras, H; Jiménez, R; Miras, C; Gomà, C
2013-04-21
This work presents CloudMC, a cloud computing application-developed in Windows Azure®, the platform of the Microsoft® cloud-for the parallelization of Monte Carlo simulations in a dynamic virtual cluster. CloudMC is a web application designed to be independent of the Monte Carlo code in which the simulations are based-the simulations just need to be of the form: input files → executable → output files. To study the performance of CloudMC in Windows Azure®, Monte Carlo simulations with penelope were performed on different instance (virtual machine) sizes, and for different number of instances. The instance size was found to have no effect on the simulation runtime. It was also found that the decrease in time with the number of instances followed Amdahl's law, with a slight deviation due to the increase in the fraction of non-parallelizable time with increasing number of instances. A simulation that would have required 30 h of CPU on a single instance was completed in 48.6 min when executed on 64 instances in parallel (speedup of 37 ×). Furthermore, the use of cloud computing for parallel computing offers some advantages over conventional clusters: high accessibility, scalability and pay per usage. Therefore, it is strongly believed that cloud computing will play an important role in making Monte Carlo dose calculation a reality in future clinical practice.
Lidierth, Malcolm
2005-02-15
This paper describes software that runs in the Spike2 for Windows environment and provides a versatile tool for generating stimuli during data acquisition from the 1401 family of interfaces (CED, UK). A graphical user interface (GUI) is used to provide dynamic control of stimulus timing. Both single stimuli and trains of stimuli can be generated. The pulse generation routines make use of programmable variables within the interface and allow these to be rapidly changed during an experiment. The routines therefore provide the ease-of-use associated with external, stand-alone pulse generators. Complex stimulus protocols can be loaded from an external text file and facilities are included to create these files through the GUI. The software consists of a Spike2 script that runs in the host PC, and accompanying routines written in the 1401 sequencer control code, that run in the 1401 interface. Handshaking between the PC and the interface card are built into the routines and provides for full integration of sampling, analysis and stimulus generation during an experiment. Control of the 1401 digital-to-analogue converters is also provided; this allows control of stimulus amplitude as well as timing and also provides a sample-hold feature that may be used to remove DC offsets and drift from recorded data.
EnviroAtlas - Austin, TX - Residents with Minimal Potential Window Views of Trees by Block Group
This EnviroAtlas dataset shows the total block group population and the percentage of the block group population that has little access to potential window views of trees at home. Having little potential access to window views of trees is defined as having no trees & forest land cover within 50 meters. The window views are considered potential because the procedure does not account for presence or directionality of windows in one's home. Forest is defined as Trees & Forest. This dataset was produced by the US EPA to support research and online mapping activities related to EnviroAtlas. EnviroAtlas (https://www.epa.gov/enviroatlas) allows the user to interact with a web-based, easy-to-use, mapping application to view and analyze multiple ecosystem services for the contiguous United States. The dataset is available as downloadable data (https://edg.epa.gov/data/Public/ORD/EnviroAtlas) or as an EnviroAtlas map service. Additional descriptive information about each attribute in this dataset can be found in its associated EnviroAtlas Fact Sheet (https://www.epa.gov/enviroatlas/enviroatlas-fact-sheets).
76 FR 66054 - Exelon Corporation Constellation Energy Group, Inc.; Notice of Filing
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-25
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. EC11-83-001] Exelon Corporation Constellation Energy Group, Inc.; Notice of Filing Take notice that, on October 11, 2011, Exelon Corporation and Constellation Energy Group, Inc. (Merger Applicants) submitted a filing styled as an answer in...
Zinge, Priyanka Ramdas; Patil, Jayaprakash
2017-01-01
The aim of this study is to evaluate and compare the effect of one shape, Neolix rotary single-file systems and WaveOne, Reciproc reciprocating single-file systems on pericervical dentin (PCD) using cone-beam computed tomography (CBCT). A total of 40 freshly extracted mandibular premolars were collected and divided into two groups, namely, Group A - Rotary: A 1 - Neolix and A 2 - OneShape and Group B - Reciprocating: B 1 - WaveOne and B 2 - Reciproc. Preoperative scans of each were taken followed by conventional access cavity preparation and working length determination with 10-k file. Instrumentation of the canal was done according to the respective file system, and postinstrumentation CBCT scans of teeth were obtained. 90 μm thick slices were obtained 4 mm apical and coronal to the cementoenamel junction. The PCD thickness was calculated as the shortest distance from the canal outline to the closest adjacent root surface, which was measured in four surfaces, i.e., facial, lingual, mesial, and distal for all the groups in the two obtained scans. There was no significant difference found between rotary single-file systems and reciprocating single-file systems in their effect on PCD, but in Group B 2 , there was most significant loss of tooth structure in the mesial, lingual, and distal surface ( P < 0.05). Reciproc single-file system removes more PCD as compared to other experimental groups, whereas Neolix single file system had the least effect on PCD.
Özkocak, I; Taşkan, M M; Gökt Rk, H; Aytac, F; Karaarslan, E Şirin
2015-01-01
The aim of this study is to evaluate increases in temperature on the external root surface during endodontic treatment with different rotary systems. Fifty human mandibular incisors with a single root canal were selected. All root canals were instrumented using a size 20 Hedstrom file, and the canals were irrigated with 5% sodium hypochlorite solution. The samples were randomly divided into the following three groups of 15 teeth: Group 1: The OneShape Endodontic File no.: 25; Group 2: The Reciproc Endodontic File no.: 25; Group 3: The WaveOne Endodontic File no.: 25. During the preparation, the temperature changes were measured in the middle third of the roots using a noncontact infrared thermometer. The temperature data were transferred from the thermometer to the computer and were observed graphically. Statistical analysis was performed using the Kruskal-Wallis analysis of variance at a significance level of 0.05. The increases in temperature caused by the OneShape file system were lower than those of the other files (P < 0.05). The WaveOne file showed the highest temperature increases. However, there were no significant differences between the Reciproc and WaveOne files. The single file rotary systems used in this study may be recommended for clinical use.
Hwang, Young-Hye; Bae, Kwang-Shik; Baek, Seung-Ho; Kum, Kee-Yeon; Lee, WooCheol; Shon, Won-Jun; Chang, Seok Woo
2014-08-01
This study used micro-computed tomographic imaging to compare the shaping ability of Mtwo (VDW, Munich, Germany), a conventional nickel-titanium file system, and Reciproc (VDW), a reciprocating file system morphologically similar to Mtwo. Root canal shaping was performed on the mesiobuccal and distobuccal canals of extracted maxillary molars. In the RR group (n = 15), Reciproc was used in a reciprocating motion (150° counterclockwise/30° clockwise, 300 rpm); in the MR group, Mtwo was used in a reciprocating motion (150° clockwise/30° counterclockwise, 300 rpm); and in the MC group, Mtwo was used in a continuous rotating motion (300 rpm). Micro-computed tomographic images taken before and after canal shaping were used to analyze canal volume change and the degree of transportation at the cervical, middle, and apical levels. The time required for canal shaping was recorded. Afterward, each file was analyzed using scanning electron microscopy. No statistically significant differences were found among the 3 groups in the time for canal shaping or canal volume change (P > .05). Transportation values of the RR and MR groups were not significantly different at any level. However, the transportation value of the MC group was significantly higher than both the RR and MR groups at the cervical and apical levels (P < .05). In the scanning electron microscopic analysis, file deformation was observed for 1 file in group RR (1/15), 3 files in group MR (3/15), and 5 files in group MC (5/15). In terms of shaping ability, Mtwo used in a reciprocating motion was not significantly different from the Reciproc system. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Apically extruded dentin debris by reciprocating single-file and multi-file rotary system.
De-Deus, Gustavo; Neves, Aline; Silva, Emmanuel João; Mendonça, Thais Accorsi; Lourenço, Caroline; Calixto, Camila; Lima, Edson Jorge Moreira
2015-03-01
This study aims to evaluate the apical extrusion of debris by the two reciprocating single-file systems: WaveOne and Reciproc. Conventional multi-file rotary system was used as a reference for comparison. The hypotheses tested were (i) the reciprocating single-file systems extrude more than conventional multi-file rotary system and (ii) the reciprocating single-file systems extrude similar amounts of dentin debris. After solid selection criteria, 80 mesial roots of lower molars were included in the present study. The use of four different instrumentation techniques resulted in four groups (n = 20): G1 (hand-file technique), G2 (ProTaper), G3 (WaveOne), and G4 (Reciproc). The apparatus used to evaluate the collection of apically extruded debris was typical double-chamber collector. Statistical analysis was performed for multiple comparisons. No significant difference was found in the amount of the debris extruded between the two reciprocating systems. In contrast, conventional multi-file rotary system group extruded significantly more debris than both reciprocating groups. Hand instrumentation group extruded significantly more debris than all other groups. The present results yielded favorable input for both reciprocation single-file systems, inasmuch as they showed an improved control of apically extruded debris. Apical extrusion of debris has been studied extensively because of its clinical relevance, particularly since it may cause flare-ups, originated by the introduction of bacteria, pulpal tissue, and irrigating solutions into the periapical tissues.
Carvalho, Maira de Souza; Junior, Emílio Carlos Sponchiado; Bitencourt Garrido, Angela Delfina; Roberti Garcia, Lucas da Fonseca; Franco Marques, André Augusto
2015-01-01
The aim of this study was to evaluate the cleaning effectiveness achieved with two reciprocating single-file systems in severely curved root canals: Reciproc and WaveOne. Twenty-five mesial roots of mandibular molars were randomly separated into two groups, according to the instrumentation system used. The negative control group consisted of five specimens that were not instrumented. The mesial canals (buccal and lingual) in Reciproc Group were instrumented with file R25 and the WaveOne group with the Primary file. The samples were submitted to histological processing and analyzed under a digital microscope. The WaveOne group presented a larger amount of debris than the Reciproc Group, however, without statistically significant difference (P > 0.05). A larger amount of debris in the control group was observed, with statistically significant difference to Reciproc and WaveOne groups (P < 0.05). The two reciprocating single-file instrumentation systems presented similar effectiveness for root canal cleaning.
Ebenezar, A.V. Rajesh; Kumar, Mohan; Sivakumar, A.
2014-01-01
Aim: The aim of this study was to evaluate the efficacy of Protaper retreatment files in comparison with RaCe, K3 and H-files for removal of gutta-percha and apically extruded debris using volumetric analysis. Materials and Methods: Forty extracted single rooted maxillary incisor teeth with straight canals and mature apices were selected for the study. After access cavity preparation, apical patency was confirmed with a size 10 K-file extending 1mm beyond the point at which it was first visible at the apical end. Working lengths were determined with the use of size 15 K-file. The canals were prepared in a step-back technique and the master apical file was size 30 for all teeth. 3% sodium hypochlorite was used as an irrigant after each instrumentation. Before final rinse, size 20 K-file was passed 1mm beyond the apex to remove any dentinal shaving plugs and maintain the apical patency. Then the canals were dried with paper points. The root canal was filled using standard gutta-percha points and zinc oxide eugenol sealer under lateral condensation technique. The teeth were then randomly divided into four groups of ten teeth each based on the instrument used for gutta percha removal. All the rotary instruments used in this study were rotated at 300rpm. The instruments used were: Group 1 – RaCe Files, Group 2 – ProTaper retreatment Files, Group 3 – K3 Files and Group 4 – H Files. The volume of the obturating material was calculated before and after removal using volumetric analysis with spiral CT. The removal efficacy with each instrument was calculated and statistically analysed. Results: The results of the study show that the ProTaper retreatment files (Group 2) (97.4%) showed the highest efficiency in the removal of obturating material, which was followed by RaCe (95.74%), K3 (92.86%) and H files (90.14%) with the efficiency in the decreasing order. Similarly the mean apical extrusion in H files (0.000 ± 0.002) was significantly lower than all the rotary instruments. However, the difference among the rotary files were not statistically significant (p>0.05). Conclusion: ProTaper retreatment files show significant difference over other groups in removal of obturating material and can be the system of choice in endodontic retreatment procedures. PMID:25584299
The Linux operating system: An introduction
NASA Technical Reports Server (NTRS)
Bokhari, Shahid H.
1995-01-01
Linux is a Unix-like operating system for Intel 386/486/Pentium based IBM-PCs and compatibles. The kernel of this operating system was written from scratch by Linus Torvalds and, although copyrighted by the author, may be freely distributed. A world-wide group has collaborated in developing Linux on the Internet. Linux can run the powerful set of compilers and programming tools of the Free Software Foundation, and XFree86, a port of the X Window System from MIT. Most capabilities associated with high performance workstations, such as networking, shared file systems, electronic mail, TeX, LaTeX, etc. are freely available for Linux. It can thus transform cheap IBM-PC compatible machines into Unix workstations with considerable capabilities. The author explains how Linux may be obtained, installed and networked. He also describes some interesting applications for Linux that are freely available. The enormous consumer market for IBM-PC compatible machines continually drives down prices of CPU chips, memory, hard disks, CDROMs, etc. Linux can convert such machines into powerful workstations that can be used for teaching, research and software development. For professionals who use Unix based workstations at work, Linux permits virtually identical working environments on their personal home machines. For cost conscious educational institutions Linux can create world-class computing environments from cheap, easily maintained, PC clones. Finally, for university students, it provides an essentially cost-free path away from DOS into the world of Unix and X Windows.
Basmaci, F; Oztan, M D; Kiyan, M
2013-09-01
To evaluate ex vivo the effectiveness of single-file instrumentation techniques compared with serial Ni-Ti rotary instrumentation with several irrigation regimens in reducing E. faecalis within root canals. A total of 81 extracted human mandibular premolar teeth with a single root canal were infected with E. faecalis before and after canal preparation. Samples were divided randomly into 9 groups, as follows: group 1-A: sterile phosphate-buffered saline + Self-adjusting file, group 1-B: 5% sodium hypochlorite + 15% EDTA + Self-adjusting file, group 1-C: 5% sodium hypochlorite + 7% maleic acid + Self-adjusting file, group 2-A: sterile phosphate-buffered saline + Reciproc (R25), group 2-B: 5% sodium hypochlorite + 15% EDTA + Reciproc (R25), group 2-C: 5% sodium hypochlorite + 7% maleic acid + Reciproc (R25), group 3-A: sterile phosphate-buffered saline + ProTaper, group 3-B: 5% sodium hypochlorite + 15% EDTA + ProTaper, group 3-C: 5% sodium hypochlorite + 7% maleic acid + ProTaper. anova was used to analyse statistically the differences in terms of reduction in colony counts between the groups, and Dunn's post hoc test was used for multiple comparisons. All techniques and irrigation regimens significantly reduced the number of bacterial cells in the root canal (P < 0.001). Comparisons amongst the groups revealed significant differences between group 1A (sterile phosphate-buffered saline + Self-adjusting file)/group 1B (5% sodium hypochlorite + 15% EDTA + Self-adjusting file) (P = 0.031), group 1A (sterile phosphate-buffered saline + Self-adjusting file)/group 2C (5% sodium hypochlorite + 7% maleic acid + Reciproc) (P = 0.003), group 2A (sterile phosphate-buffered saline + Reciproc)/group 3B (5% sodium hypochlorite + 15% EDTA + ProTaper) (P = 0.036), group 3B (5% sodium hypochlorite + 15% EDTA + ProTaper)/group 1A (sterile phosphate-buffered saline + Self-adjusting file) (P < 0.001), and group 3C (5% sodium hypochlorite + 7% maleic acid + ProTaper)/group 1A (sterile phosphate-buffered saline + Self-adjusting file) (P = 0.033). No significant differences in terms of reduction in microbial counts were observed between single-file techniques (SAF and Reciproc) and serial Ni-Ti instrumentation technique (ProTaper) in combination with irrigants. © 2013 International Endodontic Journal. Published by John Wiley & Sons Ltd.
Shivanand, Sunita; Patil, Chetan R; Thangala, Venugopal; Kumar, Pabbati Ravi; Sachdeva, Jyoti; Krishna, Akash
2013-05-01
To evaluate and compare the efficacy, cleaning ability of hand and two rotary systems in root canal retreatment. Sixty extracted premolars were retreated with following systems: Group -ProTaper Universal retreatment files, Group 2-ProFile system, Group 3-H-file. Specimens were split longitudinally and amount of remaining gutta-percha on the canal walls was assessed using direct visual scoring with the aid of stereomicroscope. Results were statistically analyzed using ANOVA test. Completely clean root canal walls were not achieved with any of the techniques investigated. However, all three systems proved to be effective for gutta-percha removal. Significant difference was found between ProTaper universal retreatment file and H-file, and also between ProFile and H-file. Under the conditions of the present study, ProTaper Universal retreatment files left significantly less guttapercha and sealer than ProFile and H-file. Rotary systems in combination with gutta-percha solvents can perform superiorly as compared to the time tested traditional hand instrumentation in root canal retreatment.
High performance solutions and data for nZEBs offices located in warm climates.
Congedo, Paolo Maria; Baglivo, Cristina; Zacà, Ilaria; D Agostino, Delia
2015-12-01
This data article contains eleven tables supporting the research article entitled: Cost-Optimal Design For Nearly Zero Energy Office Buildings Located In Warm Climates [1]. The data explain the procedure of minimum energy performance requirements presented by the European Directive (EPBD) [2] to establish several variants of energy efficiency measures with the integration of renewable energy sources in order to reach nZEBs (nearly zero energy buildings) by 2020. This files include the application of comparative methodological framework and give the cost-optimal solutions for non-residential building located in Southern Italy. The data describe office sector in which direct the current European policies and investments [3], [4]. In particular, the localization of the building, geometrical features, thermal properties of the envelope and technical systems for HVAC are reported in the first sections. Energy efficiency measures related to orientation, walls, windows, heating, cooling, dhw and RES are given in the second part of the group; this data article provides 256 combinations for a financial and macroeconomic analysis.
Cyclic fatigue resistance of four nickel-titanium rotary instruments: a comparative study.
Pedullà, Eugenio; Plotino, Gianluca; Grande, Nicola Maria; Pappalardo, Alfio; Rapisarda, Ernesto
2012-04-01
The aim of this study is to investigate cyclic fatigue resistance of four nickel - titanium rotary (NTR) instruments produced by a new method or traditional grinding processes. FOUR NTR INSTRUMENTS FROM DIFFERENT BRANDS WERE SELECTED: group 1. Twisted File produced by a new thermal treatment of nickel - titanium alloy; group 2. Revo S SU; group 3. Mtwo and group 4. BioRaCe BR3 produced by traditional grinding processes. A total of 80 instruments (20 for each group) were tested for cyclic fatigue resistance inside a curved artificial canal with a 60 degree angle of curvature and 5 mm radius of curvature. Time to fracture (TtF) from the start of the test until the moment of file breakage and the length of the fractured tip was recorded for each instrument. Means and standard deviations (SD) of TtF and fragment length were calculated. Data were subjected to one-way analysis of variance (ANOVA). Group 1 (Twisted File) showed the highest value of TtF means. Cyclic fatigue resistance of Twisted File and Mtwo was significantly higher than group 2 (Revo S SU) and 4 (BioRace BR3), while no significant differences were found between group 1 (Twisted File) and 3 (Mtwo) or group 2 (Revo S SU) and 4 (BioRaCe BR3). The cyclic fatigue resistance of Twisted File was significantly frigher than instruments produced with traditional grinding process except of Mtwo files.
Cyclic fatigue resistance of four nickel-titanium rotary instruments: a comparative study
Pedullà, Eugenio; Plotino, Gianluca; Grande, Nicola Maria; Pappalardo, Alfio; Rapisarda, Ernesto
2012-01-01
Summary Aims The aim of this study is to investigate cyclic fatigue resistance of four nickel – titanium rotary (NTR) instruments produced by a new method or traditional grinding processes. Methods Four NTR instruments from different brands were selected: group 1. Twisted File produced by a new thermal treatment of nickel – titanium alloy; group 2. Revo S SU; group 3. Mtwo and group 4. BioRaCe BR3 produced by traditional grinding processes. A total of 80 instruments (20 for each group) were tested for cyclic fatigue resistance inside a curved artificial canal with a 60 degree angle of curvature and 5 mm radius of curvature. Time to fracture (TtF) from the start of the test until the moment of file breakage and the length of the fractured tip was recorded for each instrument. Means and standard deviations (SD) of TtF and fragment length were calculated. Data were subjected to one-way analysis of variance (ANOVA). Results Group 1 (Twisted File) showed the highest value of TtF means. Cyclic fatigue resistance of Twisted File and Mtwo was significantly higher than group 2 (Revo S SU) and 4 (BioRace BR3), while no significant differences were found between group 1 (Twisted File) and 3 (Mtwo) or group 2 (Revo S SU) and 4 (BioRaCe BR3). Conclusions The cyclic fatigue resistance of Twisted File was significantly frigher than instruments produced with traditional grinding process except of Mtwo files. PMID:23087787
26 CFR 1.1502-75 - Filing of consolidated returns.
Code of Federal Regulations, 2013 CFR
2013-04-01
... first consolidated return year. A group which did not file a consolidated return for the immediately... regulations under section 1502. If a group wishes to exercise its privilege of filing a consolidated return... withdrawn after such last day (but the group may change the basis of its return at any time prior to such...
26 CFR 1.1502-75 - Filing of consolidated returns.
Code of Federal Regulations, 2011 CFR
2011-04-01
... first consolidated return year. A group which did not file a consolidated return for the immediately... regulations under section 1502. If a group wishes to exercise its privilege of filing a consolidated return... withdrawn after such last day (but the group may change the basis of its return at any time prior to such...
26 CFR 1.1502-75 - Filing of consolidated returns.
Code of Federal Regulations, 2014 CFR
2014-04-01
... first consolidated return year. A group which did not file a consolidated return for the immediately... regulations under section 1502. If a group wishes to exercise its privilege of filing a consolidated return... withdrawn after such last day (but the group may change the basis of its return at any time prior to such...
26 CFR 1.1502-75 - Filing of consolidated returns.
Code of Federal Regulations, 2012 CFR
2012-04-01
... first consolidated return year. A group which did not file a consolidated return for the immediately... regulations under section 1502. If a group wishes to exercise its privilege of filing a consolidated return... withdrawn after such last day (but the group may change the basis of its return at any time prior to such...
77 FR 64555 - Orphan Works and Mass Digitization
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-22
... owners for the project. In 2005, a group of authors and publishers filed a class action lawsuit in... F. Supp. 2d 666 (S.D.N.Y. 2011). A group of photographers and illustrators filed a related suit in... objections from various individual authors, groups, and foreign governments, the parties filed an amended...
Asheibi, Fatma; Qualtrough, Alison J E; Mellor, Anthony; Withers, Philip J; Lowe, Tristan
2014-01-01
This study compares the effectiveness of ProTaper rotary files with ProTaper retreatment and K-files in the removal of Resilon or gutta percha (GP) from canals filled either by cold lateral condensation or thermal obturation using micro-CT. Ninety-six teeth were prepared using ProTaper files and allocated into four groups (n=24): Group-1 was filled with GP/AH-Plus and Group-2 with Resilon/RealSeal using cold lateral condensation. Group-3 was filled with GP/AH-Plus and Group-4 with Resilon/RealSeal using System B and Obtura II. The roots were scanned by micro-CT. Each group was divided into two subgroups (n=12): A, retreated using ProTaper files and B, using ProTaper retreatment and K-files. The roots were scanned to calculate the volume of the remaining material. With thermal obturation, roots filled with Resilon had significantly more remaining material than GP. Obturation using thermal technique resulted in significantly less remaining material than cold condensation except Resilon retreated using ProTaper retreatment and K-files.
Comparison of working length control consistency between hand K-files and Mtwo NiTi rotary system.
Krajczár, Károly; Varga, Enikő; Marada, Gyula; Jeges, Sára; Tóth, Vilmos
2016-04-01
The purpose of this study was to investigate the consistency of working length control between hand instrumentation in comparison to engine driven Mtwo nickel-titanium rotary files. Forty extracted maxillary molars were selected and divided onto two parallel groups. The working lengths of the mesiobuccal root canals were estimated. The teeth were fixed in a phantom head. The root canal preparation was carried out group 1 (n=20) with hand K-files, (VDW, Munich, Germany) and group 2 (n=20) with Mtwo instruments (VDW, Munich, Germany). Vestibulo-oral and mesio-distal directional x-ray images were taken before the preparation with #10 K-file, inserted into the mesiobuccal root canal to the working length, and after preparation with #25, #30 and #40 files. Working lenght changes were detected with measurements between the radiological apex and the instrument tips. In the Mtwo group a difference in the working competency (p<0.05) could be noticed only in the vestibulo-oral direction from #10 to #40 file. The hand instrument group showed a significant difference in working length competency for each larger file size (p<0.05) (ANOVA). Regression analysis in the hand instrumentation group indicated a working length decrease with a mean of 0,2 mm after each consecutive file size (p<0.01). The outcome of our trial indicated a high consistency in working length control for root canal preparation under simulated clinical condition using Mtwo rotary files. Mtwo NiTi rotary file did therefore proved to be more accurate in comparison to the conventional hand instrumentation. Working length, Mtwo, nickel-titanium, hand preparation, engine driven preparation.
Comparison of working length control consistency between hand K-files and Mtwo NiTi rotary system
Krajczár, Károly; Varga, Enikő; Jeges, Sára; Tóth, Vilmos
2016-01-01
Background The purpose of this study was to investigate the consistency of working length control between hand instrumentation in comparison to engine driven Mtwo nickel-titanium rotary files. Material and Methods Forty extracted maxillary molars were selected and divided onto two parallel groups. The working lengths of the mesiobuccal root canals were estimated. The teeth were fixed in a phantom head. The root canal preparation was carried out group 1 (n=20) with hand K-files, (VDW, Munich, Germany) and group 2 (n=20) with Mtwo instruments (VDW, Munich, Germany). Vestibulo-oral and mesio-distal directional x-ray images were taken before the preparation with #10 K-file, inserted into the mesiobuccal root canal to the working length, and after preparation with #25, #30 and #40 files. Working lenght changes were detected with measurements between the radiological apex and the instrument tips. Results In the Mtwo group a difference in the working competency (p<0.05) could be noticed only in the vestibulo-oral direction from #10 to #40 file. The hand instrument group showed a significant difference in working length competency for each larger file size (p<0.05) (ANOVA). Regression analysis in the hand instrumentation group indicated a working length decrease with a mean of 0,2 mm after each consecutive file size (p<0.01). Conclusions The outcome of our trial indicated a high consistency in working length control for root canal preparation under simulated clinical condition using Mtwo rotary files. Mtwo NiTi rotary file did therefore proved to be more accurate in comparison to the conventional hand instrumentation. Key words:Working length, Mtwo, nickel-titanium, hand preparation, engine driven preparation. PMID:27034752
NASA Astrophysics Data System (ADS)
Buxbaum, T. M.; Warnick, W. K.; Polly, B.; Breen, K. J.
2007-12-01
The ARCUS Internet Media Archive (IMA) is a collection of photos, graphics, videos, and presentations about the Arctic and Antarctic that are shared through the Internet. It provides the polar research community and the public at large with a centralized location where images and video pertaining to polar research can be browsed and retrieved for a variety of uses. The IMA currently contains almost 6,500 publicly accessible photos, including 4,000 photos from the National Science Foundation (NSF) funded Teachers and Researchers Exploring and Collaborating (TREC) program, an educational research experience in which K-12 teachers participate in arctic research as a pathway to improving science education. The IMA is also the future home of all electronic media from the NSF funded PolarTREC program, a continuation of TREC that now takes place in both the Arctic and Antarctic. The IMA includes 450 video files, 270 audio files, nearly 100 graphics and logos, 28 presentations, and approximately 10,000 additional resources that are being prepared for public access. The contents of this archive are organized by file type, photographer's name, event, or by organization, with each photo or file accompanied by information on content, contributor source, and usage requirements. All the files are keyworded and all information, including file name and description, is completely searchable. ARCUS plans to continue to improve and expand the IMA with a particular focus on providing graphics depicting key arctic research results and findings as well as edited video archives of relevant scientific community meetings. To submit files or for more information and to view the ARCUS Internet Media Archive, please go to: http://media.arcus.org or email photo@arcus.org.
Khabiri, Masoud; Ebrahimi, Maziar; Saei, Mohammad Reza
2017-12-01
File fracture can interfere with cleaning and shaping of the canal and compromise periradicular healing. Autoclave sterilization may prone the files to fracture. The purpose of the present study was to determine the effect of autoclave sterilization on the cyclic fatigue resistance of Hero642 rotary instrument in two curvatures of 45 and 60 degrees. For this experimental in-vitro study, 90 Nickel-Titanium HERO 642 rotary files #30 with 0.06 taper were selected. They were divided into two groups (curvature of 45 and 60 degree) of 45 files. Each group was then subdivided into 3 subgroups; group I: no sterilization, group II: 5 cycles of sterilization and group III: 10 cycles of sterilization. Files were used in artificial canals until fracture. The cyclic fatigue was measured as the number of cycles before fracture. The data was statically analyzed by Student's t-test and two-way analysis of variance. There was a significant difference in cyclic fatigue of two curvature of 45 and 60 degrees ( p = 0.001). However, sterilization process has no significant effect on cyclic fatigue of HERO files ( p = 0.557). Sterilization had no effect on the cyclic fatigue of HERO 642 files when used in curvature of 45 or 60 degrees.
Pawar, Ajinkya M.; Pawar, Mansing; Kfir, Anda; Thakur, Bhagyashree; Mutha, Pooja; Banga, Kulwinder Singh
2017-01-01
Aim: The aim of this study was to test the effect of new protocol of glide path preparation by 20/0.04 rotary file on apical extrusion of debris when instrumenting fine curved mesial canals in mandibular molars with Self-adjusting File (SAF) and compare it to a glide path prepared by 20/0.02 hand K-file and rotary OneShape (OS) and reciprocating WaveOne (WO) file instrumentation. Materials and Methods: Sixty mandibular molars with curved mesial roots were selected and randomly divided into three groups (n = 20) for instrumentation. In two groups, glide path was prepared using 20/0.02 K-file for instrumentation by OS (size 25/0.06 taper) and WO (size 25/0.08 taper) files; in the remaining group, 20/0.04 rotary file was used for glide path preparation and instrumented by SAF (1.5 mm). The debris extruded during instrumentation was collected in preweighed Eppendorf tubes and stored in an incubator at 70°C for 5 days. Tubes containing the dry extruded debris were then weighed. One-way analysis of variance (ANOVA) was applied to the weights obtained, followed by Tukey's post hoc test for multiple comparison. Results: The mean debris (g) extruded apically was 0.000651 ± 0.000291, 0.000823 ± 0.000319, and 0.000473 ± 0.000238 for Group 1 (20/0.02 + OS), Group 2 (20/0.02 + WO), and Group 3 (20/0.04 + SAF), respectively. The groups exhibited a significant difference (P < 0.01; ANOVA). Group 3 resulted in least debris extrusion compared to Groups 1 and 2 (P < 0.01; Tukey's post hoc test). Conclusion: Glide path prepared to size 20/0.04 and SAF 1.5 mm instrumentation produce less debris in curved mesial canals of mandibular molars, compared to glide path established by 20/0.02 and instrumentation by OS and WO files. PMID:28855758
Kanaparthy, Aruna; Kanaparthy, Rosaiah
2016-05-01
Root canal treatment enjoys a high success rate all over the world and has saved billions of teeth from extraction. However, there are instances of failure, the main causes being insufficient cleaning and inadequate obturation. In such cases the most conservative treatment option would be non-surgical retreatment. It requires regaining access to the entire root canal system through removal of the original root canal filling thus permitting further cleaning and re- obturation. Removal of gutta-percha and sealer becomes a critical step to gain access to the root canal system, remove necrotic tissue debris, bacteria and infected dentin. To compare and evaluate the efficacy of manual hand Hedstrom files and two rotary retreatment file systems ProTaper Universal retreatment files and Mtwo(R) (retreatment) files in the removal of root canal filling material during root canal retreatment and the influence of the type of sealers zinc oxide eugenol and AH plus on the presence of remaining debris in the reinstrumented canals in the apical, middle and coronal third. Sixty single rooted human premolar teeth were divided into 3 Groups of 20 teeth each Group I (20 Teeth): prepared using hand K Files, Group II (20 Teeth): prepared using ProTaper rotary system and Group III (20 Teeth): prepared using Mtwo rotary system. In Groups- IA, IIA, IIIA: (10 teeth each) Obturation was done using Zinc Oxide Eugenol sealer and gutta percha. In Groups- IB, IIB, IIIB: (10 teeth each) obturation was done with AH Plus sealer and gutta percha. All the teeth were subjected to retreatment. Groups IA and IB with Hedstrom files, Groups IIA and IIB with ProTaper retreatment files and for Groups IIIA and IIIB with Mtwo retreatment Files. The roots were longitudinally split and were observed under a stereomicroscope for remaining amount of filling material on the canal walls. Statistical analysis was done using One-way ANOVA (Analysis of variance) test and Tukey HSD Test. Mtwo(R) files showed statistically significant difference in the removal of filling material in the apical third and ProTaper R in the coronal and apical thirds. Better cleaning efficacy was seen in canals obturated with zinc oxide eugenol sealer. Mtwo(R) files showed better removal of filling material than ProTaper R followed by Hedstrom files, even though there was no statistically significant difference. None of the instrument group showed complete removal of the filling material. It was easier to remove zinc oxide eugenol sealer than AH plus sealer.
NASA Technical Reports Server (NTRS)
Easley, Wesley C.
1991-01-01
Experiment critical use of RS-232 data busses in the Transport Systems Research Vehicle (TSRV) operated by the Advanced Transport Operating Systems Program Office at the NASA Langley Research Center has recently increased. Each application utilizes a number of nonidentical computer and peripheral configurations and requires task specific software development. To aid these development tasks, an IBM PC-based RS-232 bus monitoring system was produced. It can simultaneously monitor two communication ports of a PC or clone, including the nonstandard bus expansion of the TSRV Grid laptop computers. Display occurs in a separate window for each port's input with binary display being selectable. A number of other features including binary log files, screen capture to files, and a full range of communication parameters are provided.
VizieR Online Data Catalog: Spitzer photometric time series of HD 97658 (Van Grootel+, 2014)
NASA Astrophysics Data System (ADS)
Van Grootel, V.; Gillon, M.; Valencia, D.; Madhusudhan, N.; Dragomir, D.; Howe, A. R.; Burrows, A. S.; Demory, B.-O.; Deming, D.; Ehrenreich, D.; Lovis, C.; Mayor, M.; Pepe, F.; Queloz, D.; Scuflaire, R.; Seager, S.; Segransan, D.; Udry, S.
2017-07-01
We monitored HD 97658 with Spitzer's IRAC camera on 2013 August 10 from 13:01:00 to 18:27:00 UT, corresponding to a transit window as computed from the MOST transit ephemeris (Dragomir et al. 2013, J/ApJ/772/L2). These Spitzer data were acquired in the context of the Cycle 9 program 90072 (PI: M. Gillon) dedicated to the search for the transits of RV-detected low-mass planets. They consist of 2320 sets of 64 individual subarray images obtained at 4.5 μm with an integration time of 0.08 s. They are available on the Spitzer Heritage Archive database under the form of 2320 Basic Calibrated Data files calibrated by the standard Spitzer reduction pipeline (version S19.1.0). (1 data file).
SpaceHab 1 maintenance experiment
NASA Technical Reports Server (NTRS)
Bohannon, Jackie W.
1994-01-01
The SpaceHab 1 flight on STS-57 served as a test platform for evaluation of two space station payloads. The first payload evaluated a space station maintenance concept using a sweep signal generator and a 48-channel logic analyzer to perform fault detection and isolation. Crew procedures files, test setup diagram files, and software to configure the test equipment were created on the ground and uplinked on the astronauts' voice communication circuit to perform tests in flight. In order to use these files, the portable computer was operated in a multi-window configuration. The test data transmitted to the ground allowing the ground staff to identify the cause of the fault and provide the crew with the repair procedures and diagrams. The crew successfully repaired the system under test. The second payload investigated hand soldering and de-soldering of standard components on printed circuit (PC) boards in zero gravity. It also used a new type of intra-vehicular foot restraints which uses the neutral body posture in zero-g to provide retention of the crew without their conscious attention.
Geiss, Karla; Meyer, Martin
2013-09-01
Standardized mortality ratios and standardized incidence ratios are widely used in cohort studies to compare mortality or incidence in a study population to that in the general population on a age-time-specific basis, but their computation is not included in standard statistical software packages. Here we present a user-friendly Microsoft Windows program for computing standardized mortality ratios and standardized incidence ratios based on calculation of exact person-years at risk stratified by sex, age and calendar time. The program offers flexible import of different file formats for input data and easy handling of general population reference rate tables, such as mortality or incidence tables exported from cancer registry databases. The application of the program is illustrated with two examples using empirical data from the Bavarian Cancer Registry. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
The X-windows interactive navigation data editor
NASA Technical Reports Server (NTRS)
Rinker, G. C.
1992-01-01
A new computer program called the X-Windows Interactive Data Editor (XIDE) was developed and demonstrated as a prototype application for editing radio metric data in the orbit-determination process. The program runs on a variety of workstations and employs pull-down menus and graphical displays, which allow users to easily inspect and edit radio metric data in the orbit data files received from the Deep Space Network (DSN). The XIDE program is based on the Open Software Foundation OSF/Motif Graphical User Interface (GUI) and has proven to be an efficient tool for editing radio metric data in the navigation operations environment. It was adopted by the Magellan Navigation Team as their primary data-editing tool. Because the software was designed from the beginning to be portable, the prototype was successfully moved to new workstation environments. It was also itegrated into the design of the next-generation software tool for DSN multimission navigation interactive launch support.
Evaluation of apically extruded debris during root canal retreatment with several NiTi systems.
Dincer, A N; Er, O; Canakci, B C
2015-12-01
To compare the amount of debris extruded apically during root canal retreatment using ProTaper, Mtwo and Reciproc instruments with hand H-files. In total, 60 freshly extracted human mandibular incisor teeth were used. All root canals were prepared with a Reciproc R25 file than filled with Gutta-percha and AH Plus sealer using cold lateral condensation before being assigned randomly to four groups (n = 15 each). In group 1, root fillings were removed with the Protaper Universal retreatment system; ProTaper Universal F3 and F4 instruments were used for the final preparation. In group 2, root fillings were removed with the Mtwo retreatment system; Mtwo size 30, .06 taper, size 35, .06 taper and size 40, .06 taper files were used for the final preparation. In group 3, root fillings were removed with Reciproc R25 instruments; Reciproc R40 instruments were used for the final preparation. In group 4, the root fillings were removed with Gates Glidden burs and sizes 35, 30 and 25 H-files; for final preparation, a size 40 H-file was used. Glass vials were used for debris collection. The vials were weighed before and after Gutta-percha removal. Additionally, the times required for the retreatment procedures were recorded. Data were analysed statistically using one-way analysis of variance. The Reciproc system produced significantly smaller amounts of apical extruded debris than the other groups (P < 0.05). There was no significant difference between the Mtwo, H-file and ProTaper groups. The ProTaper and Reciproc groups required significantly less time than the Mtwo and H-file groups (P < 0.001). Use of the reciprocating single file system resulted in the extrusion of significantly less debris compared with the full-sequence rotary NiTi instruments and hand filing. Use of the ProTaper and Reciproc instruments required less time for retreatment procedures than use of the Mtwo or H-file. © 2014 International Endodontic Journal. Published by John Wiley & Sons Ltd.
Legato: Personal Computer Software for Analyzing Pressure-Sensitive Paint Data
NASA Technical Reports Server (NTRS)
Schairer, Edward T.
2001-01-01
'Legato' is personal computer software for analyzing radiometric pressure-sensitive paint (PSP) data. The software is written in the C programming language and executes under Windows 95/98/NT operating systems. It includes all operations normally required to convert pressure-paint image intensities to normalized pressure distributions mapped to physical coordinates of the test article. The program can analyze data from both single- and bi-luminophore paints and provides for both in situ and a priori paint calibration. In addition, there are functions for determining paint calibration coefficients from calibration-chamber data. The software is designed as a self-contained, interactive research tool that requires as input only the bare minimum of information needed to accomplish each function, e.g., images, model geometry, and paint calibration coefficients (for a priori calibration) or pressure-tap data (for in situ calibration). The program includes functions that can be used to generate needed model geometry files for simple model geometries (e.g., airfoils, trapezoidal wings, rotor blades) based on the model planform and airfoil section. All data files except images are in ASCII format and thus are easily created, read, and edited. The program does not use database files. This simplifies setup but makes the program inappropriate for analyzing massive amounts of data from production wind tunnels. Program output consists of Cartesian plots, false-colored real and virtual images, pressure distributions mapped to the surface of the model, assorted ASCII data files, and a text file of tabulated results. Graphical output is displayed on the computer screen and can be saved as publication-quality (PostScript) files.
76 FR 8375 - Notice of Filing of Plats of Survey; Arizona
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-14
... North, Range 30 East, accepted July 20, 2010, and officially filed July 23, 2010, for Group 1062... officially filed July 23, 2010, for Group 1062, Arizona. This plat was prepared at the request of the Bureau...
A prototype of a beam steering assistant tool for accelerator operations
DOE Office of Scientific and Technical Information (OSTI.GOV)
M. Bickley; P. Chevtsov
2006-10-24
The CEBAF accelerator provides nuclear physics experiments at Jefferson Lab with high quality electron beams. Three experimental end stations can simultaneously receive the beams with different energies and intensities. For each operational mode, the accelerator setup procedures are complicated and require very careful checking of beam spot sizes and positions on multiple beam viewers. To simplify these procedures and make them reproducible, a beam steering assistant GUI tool has been created. The tool is implemented as a multi-window control screen. The screen has an interactive graphical object window, which is an overlay on top of a digitized live video imagemore » from a beam viewer. It allows a user to easily create and edit any graphical objects consisting of text, ellipses, and lines, right above the live beam viewer image and then save them in a file that is called a beam steering template. The template can show, for example, the area within which the beam must always be on the viewer. Later, this template can be loaded in the interactive graphical object window to help accelerator operators steer the beam to the specified area on the viewer.« less
TIGER: Turbomachinery interactive grid generation
NASA Technical Reports Server (NTRS)
Soni, Bharat K.; Shih, Ming-Hsin; Janus, J. Mark
1992-01-01
A three dimensional, interactive grid generation code, TIGER, is being developed for analysis of flows around ducted or unducted propellers. TIGER is a customized grid generator that combines new technology with methods from general grid generation codes. The code generates multiple block, structured grids around multiple blade rows with a hub and shroud for either C grid or H grid topologies. The code is intended for use with a Euler/Navier-Stokes solver also being developed, but is general enough for use with other flow solvers. TIGER features a silicon graphics interactive graphics environment that displays a pop-up window, graphics window, and text window. The geometry is read as a discrete set of points with options for several industrial standard formats and NASA standard formats. Various splines are available for defining the surface geometries. Grid generation is done either interactively or through a batch mode operation using history files from a previously generated grid. The batch mode operation can be done either with a graphical display of the interactive session or with no graphics so that the code can be run on another computer system. Run time can be significantly reduced by running on a Cray-YMP.
PyCorrFit-generic data evaluation for fluorescence correlation spectroscopy.
Müller, Paul; Schwille, Petra; Weidemann, Thomas
2014-09-01
We present a graphical user interface (PyCorrFit) for the fitting of theoretical model functions to experimental data obtained by fluorescence correlation spectroscopy (FCS). The program supports many data file formats and features a set of tools specialized in FCS data evaluation. The Python source code is freely available for download from the PyCorrFit web page at http://pycorrfit.craban.de. We offer binaries for Ubuntu Linux, Mac OS X and Microsoft Windows. © The Author 2014. Published by Oxford University Press.
2010-09-01
differentiated between source codes and input/output files. The text makes references to a REMChlor-GoldSim model. The text also refers to the REMChlor...To the extent possible, the instructions should be accurate and precise. The documentation should differentiate between describing what is actually...Windows XP operating system Model Input Paran1eters. · n1e input parameters were identical to those utilized and reported by CDM (See Table .I .from
Schilling, Birgit; Gibson, Bradford W.; Hunter, Christie L.
2017-01-01
Data-independent acquisition is a powerful mass spectrometry technique that enables comprehensive MS and MS/MS analysis of all detectable species, providing an information rich data file that can be mined deeply. Here, we describe how to acquire high-quality SWATH® Acquisition data to be used for large quantitative proteomic studies. We specifically focus on using variable sized Q1 windows for acquisition of MS/MS data for generating higher specificity quantitative data. PMID:28188533
DOE Office of Scientific and Technical Information (OSTI.GOV)
Humphrey, Walter R.
CMS is a Windows application for tracking chemical inventories. Partners will use this application to record chemicals that are stored on their site and to perform periodic inventories of those chemicals. The application records information about stored chemicals from user input via the keyboard and barcode readers and stores that information into a single-file database (SQLite). A simple user login mechanism is used to control access to functions in the application. A user interface is provided that allows users to search the database and update data in the database.
2006-09-01
spiral development cycle involved transporting the software processes from a Windows XP / MATLAB environment to a Linux / C++ environment. This...tested on. Additionally, in the case of the GUMSTIX PC boards, the LINUX operating system is burned into the read-only memory. Lastly, both PC-104 and...both the real-time environment and the post-processed en - vironment. When the system operates in real-time mode, an output file is generated which
Data acquisition, processing and firing aid software for multichannel EMP simulation
NASA Astrophysics Data System (ADS)
Eumurian, Gregoire; Arbaud, Bruno
1986-08-01
Electromagnetic compatibility testing yields a large quantity of data for systematic analysis. An automated data acquisition system has been developed. It is based on standard EMP instrumentation which allows a pre-established program to be followed whilst orientating the measurements according to the results obtained. The system is controlled by a computer running interactive programs (multitask windows, scrollable menus, mouse, etc.) which handle the measurement channels, files, displays and process data in addition to providing an aid to firing.
26 CFR 1.562-3 - Distributions by a member of an affiliated group.
Code of Federal Regulations, 2011 CFR
2011-04-01
... Distributions by a member of an affiliated group. A personal holding company which files or is required to file a consolidated return with other members of an affiliated group may be required to file a separate personal holding company schedule by reason of the limitations and exceptions provided in section 542(b...
26 CFR 1.562-3 - Distributions by a member of an affiliated group.
Code of Federal Regulations, 2010 CFR
2010-04-01
... Distributions by a member of an affiliated group. A personal holding company which files or is required to file a consolidated return with other members of an affiliated group may be required to file a separate personal holding company schedule by reason of the limitations and exceptions provided in section 542(b...
Effects of leukocyte-platelet rich fibrin on postoperative complications of direct sinus lifting.
Gurler, Gokhan; Delilbasi, Cagri
2016-08-01
Blood products have been widely used in soft tissue and bone regeneration in oral and maxillofacial surgery. The purpose of this study is to evaluate the effects of leukocyte-platelet rich fibrin (L-PRF) following direct sinus lifting procedure. Twenty-eight patients were included in the study. Direct sinus lifting was performed via lateral window approach under conscious sedation and local anesthesia. Bony window and sinus floor elevation were performed using piezosurgery device. Two groups were formed. In the first group an allogenous bone graft and L-PRF mixture was used as grafting material. The L-PRF membrane was used to close the lateral window. In the second group, only allogenous bone was used for grafting and resorbable collagen membrane was used to close the lateral window. Pain, swelling, sleeping, eating, phonetics, activities of daily living, missed work days and soft tissue healing were evaluated postoperatively. Data of 24 patients were evaluated. Improvements were seen in the studied parameters in the L-PRF group; however, the difference was not significant between the two groups (P>0.05). The use of L-PRF and allogenous bone graft in combination with L-PRF membrane does not significantly improve postoperative complications following direct sinus lifting.
Chen, Keguang; Lyu, Huiying; Xie, Youzhou; Yang, Lin; Zhang, Tianyu; Dai, Peidong
2015-01-01
The aim of this study was to measure the round window niche (RWN) among congenital aural atresia (CAA), congenital aural stenosis (CAS) and control groups and to analyze whether differences exist between them. Computed tomography images of 10 normal subjects (20 ears), 27 CAS patients (30 ears) and 25 CAA patients (30 ears) were analyzed. We measured RWN on the basis of 3-dimensional reconstruction. The anterior wall length and the depth of RWN were smaller in control group than those in the CAS group; furthermore, the anterior wall length and the depth of RWN in CAS group were smaller than those in CAA group (P < 0.05). The posterior wall length of RWN was found smaller in the control group than that in both hCAS and CAA groups (P < 0.05). The superior and inferior wall lengths of RWN were found smaller in control group than those in the CAA group (P < 0.05). There were no statistically significant differences in the sizes of the round window membrane and niche opening or the angle between the plane of the RWN opening and the round window membrane plane among all groups. The RWN walls lengths and its depth tended to be longer with the aggravation of the aural malformations. Our calculation results may provide some information for a better design and a safer implantation of the floating mass transducer in the area of RWN.
Pawar, Ajinkya M; Thakur, Bhagyashree; Metzger, Zvi; Kfir, Anda; Pawar, Mansing
2016-01-01
Aim: The current ex vivo study compared the efficacy of removing root fillings using ProTaper retreatment files followed by either WaveOne reciprocating file or the Self-Adjusting File (SAF). Materials and Methods: Forty maxillary canines with single oval root canal were selected and sectioned to obtain 18-mm root segments. The root canals were instrumented with WaveOne primary files, followed by obturation using warm lateral compaction, and the sealer was allowed to fully set. The teeth were then divided into two equal groups (N = 20). Initial removal of the bulk of root filling material was performed with ProTaper retreatment files, followed by either WaveOne files (Group 1) or SAF (Group 2). Endosolv R was used as a gutta-percha softener. Preoperative and postoperative high-resolution cone-beam computed tomography (CBCT) was used to measure the volume of the root filling residue that was left after the procedure. Statistical analysis was performed using t-test. Results: The mean volume of root filling residue in Group 1 was 9.4 (±0.5) mm3, whereas in Group 2 the residue volume was 2.6 (±0.4) mm3, (P < 0.001; t-test). Conclusions: When SAF was used after ProTaper retreatment files, significantly less root filling residue was left in the canals compared to when WaveOne was used. PMID:26957798
The sterilization of endodontic hand files.
Hurtt, C A; Rossman, L E
1996-06-01
Several different methods of file sterilization were analyzed to determine the best method of providing complete file sterility, including the metal shaft and plastic handle. Six test groups of 15 files were studied using Bacillus stearothermophilus as the test organism. Groups were "sterilized" by glutaraldehyde immersion, steam autoclaving, and various techniques of salt sterilization. Only proper steam autoclaving reliably produced completely sterile instruments. Salt sterilization and glutaraldehyde solutions may not be adequate sterilization methods for endodontic hand files and should not be relied on to provide completely sterile instruments.
Mahesh, MC; Bhandary, Shreetha
2017-01-01
Introduction Stresses generated during root canal instrumentation have been reported to cause apical cracks. The smaller, less pronounced defects like cracks can later propagate into vertical root fracture, when the tooth is subjected to repeated stresses from endodontic or restorative procedures. Aim This study evaluated occurrence of apical cracks with stainless steel hand files, rotary NiTi RaCe and K3 files at two different instrumentation lengths. Materials and Methods In the present in vitro study, 60 mandibular premolars were mounted in resin blocks with simulated periodontal ligament. Apical 3 mm of the root surfaces were exposed and stained using India ink. Preoperative images of root apices were obtained at 100x using stereomicroscope. The teeth were divided into six groups of 10 each. First two groups were instrumented with stainless steel files, next two groups with rotary NiTi RaCe files and the last two groups with rotary NiTi K3 files. The instrumentation was carried out till the apical foramen (Working Length-WL) and 1 mm short of the apical foramen (WL-1) with each file system. After root canal instrumentation, postoperative images of root apices were obtained. Preoperative and postoperative images were compared and the occurrence of cracks was recorded. Descriptive statistical analysis and Chi-square tests were used to analyze the results. Results Apical root cracks were seen in 30%, 35% and 20% of teeth instrumented with K-files, RaCe files and K3 files respectively. There was no statistical significance among three instrumentation systems in the formation of apical cracks (p=0.563). Apical cracks were seen in 40% and 20% of teeth instrumented with K-files; 60% and 10% of teeth with RaCe files and 40% and 0% of teeth with K3 files at WL and WL-1 respectively. For groups instrumented with hand files there was no statistical significance in number of cracks at WL and WL-1 (p=0.628). But for teeth instrumented with RaCe files and K3 files significantly more number of cracks were seen at WL than WL-1 (p=0.057 for RaCe files and p=0.087 for K3 files). Conclusion There was no statistical significance between stainless steel hand files and rotary files in terms of crack formation. Instrumentation length had a significant effect on the formation of cracks when rotary files were used. Using rotary instruments 1 mm short of apical foramen caused lesser crack formation. But, there was no statistically significant difference in number of cracks formed with hand files at two instrumentation levels. PMID:28274036
Devale, Madhuri R; Mahesh, M C; Bhandary, Shreetha
2017-01-01
Stresses generated during root canal instrumentation have been reported to cause apical cracks. The smaller, less pronounced defects like cracks can later propagate into vertical root fracture, when the tooth is subjected to repeated stresses from endodontic or restorative procedures. This study evaluated occurrence of apical cracks with stainless steel hand files, rotary NiTi RaCe and K3 files at two different instrumentation lengths. In the present in vitro study, 60 mandibular premolars were mounted in resin blocks with simulated periodontal ligament. Apical 3 mm of the root surfaces were exposed and stained using India ink. Preoperative images of root apices were obtained at 100x using stereomicroscope. The teeth were divided into six groups of 10 each. First two groups were instrumented with stainless steel files, next two groups with rotary NiTi RaCe files and the last two groups with rotary NiTi K3 files. The instrumentation was carried out till the apical foramen (Working Length-WL) and 1 mm short of the apical foramen (WL-1) with each file system. After root canal instrumentation, postoperative images of root apices were obtained. Preoperative and postoperative images were compared and the occurrence of cracks was recorded. Descriptive statistical analysis and Chi-square tests were used to analyze the results. Apical root cracks were seen in 30%, 35% and 20% of teeth instrumented with K-files, RaCe files and K3 files respectively. There was no statistical significance among three instrumentation systems in the formation of apical cracks (p=0.563). Apical cracks were seen in 40% and 20% of teeth instrumented with K-files; 60% and 10% of teeth with RaCe files and 40% and 0% of teeth with K3 files at WL and WL-1 respectively. For groups instrumented with hand files there was no statistical significance in number of cracks at WL and WL-1 (p=0.628). But for teeth instrumented with RaCe files and K3 files significantly more number of cracks were seen at WL than WL-1 (p=0.057 for RaCe files and p=0.087 for K3 files). There was no statistical significance between stainless steel hand files and rotary files in terms of crack formation. Instrumentation length had a significant effect on the formation of cracks when rotary files were used. Using rotary instruments 1 mm short of apical foramen caused lesser crack formation. But, there was no statistically significant difference in number of cracks formed with hand files at two instrumentation levels.
Khabiri, Masoud; Ebrahimi, Maziar; Saei, Mohammad Reza
2017-01-01
Statement of the Problem: File fracture can interfere with cleaning and shaping of the canal and compromise periradicular healing. Autoclave sterilization may prone the files to fracture. Purpose: The purpose of the present study was to determine the effect of autoclave sterilization on the cyclic fatigue resistance of Hero642 rotary instrument in two curvatures of 45 and 60 degrees. Materials and Method: For this experimental in-vitro study, 90 Nickel-Titanium HERO 642 rotary files #30 with 0.06 taper were selected. They were divided into two groups (curvature of 45 and 60 degree) of 45 files. Each group was then subdivided into 3 subgroups; group I: no sterilization, group II: 5 cycles of sterilization and group III: 10 cycles of sterilization. Files were used in artificial canals until fracture. The cyclic fatigue was measured as the number of cycles before fracture. The data was statically analyzed by Student’s t-test and two-way analysis of variance. Results: There was a significant difference in cyclic fatigue of two curvature of 45 and 60 degrees (p= 0.001). However, sterilization process has no significant effect on cyclic fatigue of HERO files (p= 0.557). Conclusion: Sterilization had no effect on the cyclic fatigue of HERO 642 files when used in curvature of 45 or 60 degrees. PMID:29201971
Dagna, Alberto; El Abed, Rashid; Hussain, Sameeha; Abu-Tahun, Ibrahim H; Visai, Livia; Bertoglio, Federico; Bosco, Floriana; Beltrami, Riccardo; Poggio, Claudio; Kim, Hyeon-Cheol
2017-11-01
This study compared the amount of apically extruded bacteria during the glide-path preparation by using multi-file and single-file glide-path establishing nickel-titanium (NiTi) rotary systems. Sixty mandibular first molar teeth were used to prepare the test apparatus. They were decoronated, blocked into glass vials, sterilized in ethylene oxide gas, infected with a pure culture of Enterococcus faecalis, randomly assigned to 5 experimental groups, and then prepared using manual stainless-steel files (group KF) and glide-path establishing NiTi rotary files (group PF with PathFiles, group GF with G-Files, group PG with ProGlider, and group OG with One G). At the end of canal preparation, 0.01 mL NaCl solution was taken from the experimental vials. The suspension was plated on brain heart infusion agar and colonies of bacteria were counted, and the results were given as number of colony-forming units (CFU). The manual instrumentation technique tested in group KF extruded the highest number of bacteria compared to the other 4 groups ( p < 0.05). The 4 groups using rotary glide-path establishing instruments extruded similar amounts of bacteria. All glide-path establishment instrument systems tested caused a measurable apical extrusion of bacteria. The manual glide-path preparation showed the highest number of bacteria extruded compared to the other NiTi glide-path establishing instruments.
Subramaniam, Priya; Girish Babu, K L; Tabrez, T A
2016-01-01
The present SEM study was undertaken to evaluate the effect of root canal instrumentation using both manual and rotary files in the root canals of primary anterior teeth. Thirty freshly extracted primary maxillary incisors were divided into 3 groups of 10 teeth each. In Group I, root canals were instrumented with rotary NiTi files; in Group II, the root canals were instrumented using manual NiTi K files and; in Group III, manual instrumentation was done with stainless steel K files. Longitudinal sections were prepared and processed for observation under SEM at the coronal, middle and apical thirds. Scoring of smear layer was done according to Hulsmann and the data obtained was subjected to statistical analysis. Rotary files cleaned the coronal and middle thirds of root canals more effectively. Statistically there was no significant difference between the groups. Lowest score of 2.6 in the apical third of root canals was seen with hand NiTi files. Rotary instrumentation was as effective as manual instrumentation in removal of smear layer in the root canals of primary anterior teeth.
Collective operations in a file system based execution model
Shinde, Pravin; Van Hensbergen, Eric
2013-02-12
A mechanism is provided for group communications using a MULTI-PIPE synthetic file system. A master application creates a multi-pipe synthetic file in the MULTI-PIPE synthetic file system, the master application indicating a multi-pipe operation to be performed. The master application then writes a header-control block of the multi-pipe synthetic file specifying at least one of a multi-pipe synthetic file system name, a message type, a message size, a specific destination, or a specification of the multi-pipe operation. Any other application participating in the group communications then opens the same multi-pipe synthetic file. A MULTI-PIPE file system module then implements the multi-pipe operation as identified by the master application. The master application and the other applications then either read or write operation messages to the multi-pipe synthetic file and the MULTI-PIPE synthetic file system module performs appropriate actions.
Collective operations in a file system based execution model
Shinde, Pravin; Van Hensbergen, Eric
2013-02-19
A mechanism is provided for group communications using a MULTI-PIPE synthetic file system. A master application creates a multi-pipe synthetic file in the MULTI-PIPE synthetic file system, the master application indicating a multi-pipe operation to be performed. The master application then writes a header-control block of the multi-pipe synthetic file specifying at least one of a multi-pipe synthetic file system name, a message type, a message size, a specific destination, or a specification of the multi-pipe operation. Any other application participating in the group communications then opens the same multi-pipe synthetic file. A MULTI-PIPE file system module then implements the multi-pipe operation as identified by the master application. The master application and the other applications then either read or write operation messages to the multi-pipe synthetic file and the MULTI-PIPE synthetic file system module performs appropriate actions.
Code of Federal Regulations, 2010 CFR
2010-04-01
... on or before August 11, 1999. (2) In general. Affiliated group of corporations filing a consolidated... thereto. However, for taxable years prior to 1983, affiliated groups may have determined their overall... contained in §§ 1.904(f)-1 through 1.904(f)-6 are applicable to affiliated groups filing consolidated...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-01
... need to submit a photo for a child who is already a U.S. citizen or a Legal Permanent Resident. Group... Joint Photographic Experts Group (JPEG) format; it must have a maximum image file size of two hundred... (dpi); the image file format in Joint Photographic Experts Group (JPEG) format; the maximum image file...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-27
... already a U.S. citizen or a Lawful Permanent Resident, but you will not be penalized if you do. Group... specifications: Image File Format: The miage must be in the Joint Photographic Experts Group (JPEG) format. Image... in the Joint Photographic Experts Group (JPEG) format. Image File Size: The maximum image file size...
VizieR Online Data Catalog: Seven sdB eclipsing binaries data (Pulley+, 2018)
NASA Astrophysics Data System (ADS)
Pulley, D.; Faillace, G.; Smith, D.; Watkins, A.; von Harrach, S.
2017-11-01
File tablea1 contains a list of the observatories and equipment used by this group to gather the data. File tablea2 contains all the observations made by this group It contains timing filter and observatory data. File tablea3 contains a list of the systems studied in this paper with reference stars used in the analysis. (4 data files).
WINDOWS: a program for the analysis of spectral data foil activation measurements
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stallmann, F.W.; Eastham, J.F.; Kam, F.B.K.
The computer program WINDOWS together with its subroutines is described for the analysis of neutron spectral data foil activation measurements. In particular, the unfolding of the neutron differential spectrum, estimated windows and detector contributions, upper and lower bounds for an integral response, and group fluxes obtained from neutron transport calculations. 116 references. (JFP)
Ramazani, Nahid; Mohammadi, Abbas; Amirabadi, Foroogh; Ramazani, Mohsen; Ehsani, Farzane
2016-01-01
Background. Efficient canal preparation is the key to successful root canal treatment. This study aimed to assess the cleaning and shaping ability, preparation time and file deformation of rotary, reciprocating and manual instrumentation in canal preparation of primary molars. Methods. The mesiobuccal canals of 64 extracted primary mandibular second molars were injected with India ink. The samples were randomly divided into one control and three experimental groups. Experimental groups were instrumented with K-file, Mtwo in continuous rotation and Reciproc in reciprocating motion, respectively. The control group received no treatment. The files were discarded after four applications. Shaping ability was evaluated using CBCT. After clearing, ink removal was scored. Preparation time and file fracture or deformation was also recorded. Data were analyzed with SPSS 19 using chi-squared, Fisher's exact test, Kruskal-Wallis and post hoc tests at a significance level of 0.05. Results. Considering cleanliness, at coronal third Reciproc was better than K-file (P < 0.001), but not more effective than Mtwo (P = 0.080). Furthermore, Mtwo leaved the canal cleaner than K-file (P = 0.001). In the middle third, only Reciproc exhibited better cleaning efficacy than K-file (P = 0.005). In the apical third, no difference was detected between the groups (P = 0.794). Regarding shaping ability, no differences were found between Reciproc and Mtwo (P = 1.00). Meanwhile, both displayed better shaping efficacy than K-file (P < 0.05). Between each two groups, there were differences in preparation time (P < 0.05), with Reciproc being the fastest. No file failure occurred. Conclusion. Fast and sufficient cleaning and shaping could be achieved with Mtwo and especially with Reciproc.
Hamuro, Yoshitomo
2017-03-01
A new strategy to analyze amide hydrogen/deuterium exchange mass spectrometry (HDX-MS) data is proposed, utilizing a wider time window and isotope envelope analysis of each peptide. While most current scientific reports present HDX-MS data as a set of time-dependent deuteration levels of peptides, the ideal HDX-MS data presentation is a complete set of backbone amide hydrogen exchange rates. The ideal data set can provide single amide resolution, coverage of all exchange events, and the open/close ratio of each amide hydrogen in EX2 mechanism. Toward this goal, a typical HDX-MS protocol was modified in two aspects: measurement of a wider time window in HDX-MS experiments and deconvolution of isotope envelope of each peptide. Measurement of a wider time window enabled the observation of deuterium incorporation of most backbone amide hydrogens. Analysis of the isotope envelope instead of centroid value provides the deuterium distribution instead of the sum of deuteration levels in each peptide. A one-step, global-fitting algorithm optimized exchange rate and deuterium retention during the analysis of each amide hydrogen by fitting the deuterated isotope envelopes at all time points of all peptides in a region. Application of this strategy to cytochrome c yielded 97 out of 100 amide hydrogen exchange rates. A set of exchange rates determined by this approach is more appropriate for a patent or regulatory filing of a biopharmaceutical than a set of peptide deuteration levels obtained by a typical protocol. A wider time window of this method also eliminates false negatives in protein-ligand binding site identification. Graphical Abstract ᅟ.
NASA Astrophysics Data System (ADS)
Hamuro, Yoshitomo
2017-03-01
A new strategy to analyze amide hydrogen/deuterium exchange mass spectrometry (HDX-MS) data is proposed, utilizing a wider time window and isotope envelope analysis of each peptide. While most current scientific reports present HDX-MS data as a set of time-dependent deuteration levels of peptides, the ideal HDX-MS data presentation is a complete set of backbone amide hydrogen exchange rates. The ideal data set can provide single amide resolution, coverage of all exchange events, and the open/close ratio of each amide hydrogen in EX2 mechanism. Toward this goal, a typical HDX-MS protocol was modified in two aspects: measurement of a wider time window in HDX-MS experiments and deconvolution of isotope envelope of each peptide. Measurement of a wider time window enabled the observation of deuterium incorporation of most backbone amide hydrogens. Analysis of the isotope envelope instead of centroid value provides the deuterium distribution instead of the sum of deuteration levels in each peptide. A one-step, global-fitting algorithm optimized exchange rate and deuterium retention during the analysis of each amide hydrogen by fitting the deuterated isotope envelopes at all time points of all peptides in a region. Application of this strategy to cytochrome c yielded 97 out of 100 amide hydrogen exchange rates. A set of exchange rates determined by this approach is more appropriate for a patent or regulatory filing of a biopharmaceutical than a set of peptide deuteration levels obtained by a typical protocol. A wider time window of this method also eliminates false negatives in protein-ligand binding site identification.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morcos, M; Mitrou, E
2015-06-15
Purpose: Using Linac dynamic logs (Dynalogs) we evaluate the impact of a single failing MLC motor on the deliverability of an IMRT plan by assessing the recalculated dose volume histograms (DVHs) taking the delivered MLC positions and beam hold-offs into consideration. Methods: This is a retrospective study based on a deteriorating MLC motor (leaf 36B) which was observed to be failing via Dynalog analysis. To investigate further, Eclipse-importable MLC files were generated from Dynalogs to recalculate the actual delivered dose and to assess the clinical impact through DVHs. All deliveries were performed on a Varian 21EX linear accelerator equipped withmore » Millennium-120 MLC. The analysis of Dynalog files and subsequent conversion to Eclipse-importable MLC files were all performed by in-house programming in Python. Effects on plan DVH are presented in the following section on a particular brain-IMRT plan which was delivered with a failing MLC motor which was then replaced. Results: Global max dose increased by 13.5%, max dose to the brainstem PRV increased by 8.2%, max dose to the optic chiasm increased by 7.6%, max dose to optic nerve increased by 8.8% and the mean dose to the PTV increased by 7.9% when comparing the original plan to the fraction with the failing MLC motor. The reason the dose increased was due to the failure being on the B-bank which is the lagging side on a sliding window delivery, therefore any failures on this side will cause an over-irradiation as the B-bank leaves struggles to keep the window from growing. Conclusion: Our findings suggest that a single failing MLC motor may jeopardize the entire delivery. This may be due to the bad MLC motor drawing too much current causing all MLCs on the same bank to underperform. This hypothesis will be investigated in a future study.« less
Preparing PNNL Reports with LaTeX
DOE Office of Scientific and Technical Information (OSTI.GOV)
Waichler, Scott R.
2005-06-01
LaTeX is a mature document preparation system that is the standard in many scientific and academic workplaces. It has been used extensively by scattered individuals and research groups within PNNL for years, but until now there have been no centralized or lab-focused resources to help authors and editors. PNNL authors and editors can produce correctly formatted PNNL or PNWD reports using the LaTeX document preparation system and the available template files. Please visit the PNNL-LaTeX Project (http://stidev.pnl.gov/resources/latex/, inside the PNNL firewall) for additional information and files. In LaTeX, document content is maintained separately from document structure for the most part.more » This means that the author can easily produce the same content in different formats and, more importantly, can focus on the content and write it in a plain text file that doesn't go awry, is easily transferable, and won't become obsolete due to software changes. LaTeX produces the finest print quality output; its typesetting is noticeably better than that of MS Word. This is particularly true for mathematics, tables, and other types of special text. Other benefits of LaTeX: easy handling of large numbers of figures and tables; automatic and error-free captioning, citation, cross-referencing, hyperlinking, and indexing; excellent published and online documentation; free or low-cost distributions for Windows/Linux/Unix/Mac OS X. This document serves two purposes: (1) it provides instructions to produce reports formatted to PNNL requirements using LaTeX, and (2) the document itself is in the form of a PNNL report, providing examples of many solved formatting challenges. Authors can use this document or its skeleton version (with formatting examples removed) as the starting point for their own reports. The pnnreport.cls class file and pnnl.bst bibliography style file contain the required formatting specifications for reports to the Department of Energy. Options are also provided for formatting PNWD (non-1830) reports. This documentation and the referenced files are meant to provide a complete package of PNNL particulars for authors and editors who wish to prepare technical reports using LaTeX. The example material in this document was borrowed from real reports and edited for demonstration purposes. The subject matter content of the example material is not relevant here and generally does not make literal sense in the context of this document. Brackets ''[]'' are used to denote large blocks of example text. The PDF file for this report contains hyperlinks to facilitate navigation. Hyperlinks are provided for all cross-referenced material, including section headings, figures, tables, and references. Not all hyperlinks are colored but will be obvious when you move your mouse over them.« less
Apical extrusion of debris by supplementary files used for retreatment: An ex vivo comparative study
Pawar, Ajinkya M.; Pawar, Mansing; Metzger, Zvi; Thakur, Bhagyashree
2016-01-01
Aim: This study evaluated whether using supplementary files for removing root canal filling residues after ProTaper Universal Retreatment files (RFs) increased the debris extrusion apically. Materials and Methods: Eighty mandibular premolars with single root and canal were instrumented with ProTaper Universal rotary system (SX-F3) and obturated. The samples were divided randomly into four groups (n = 20). Group 1 served as a control; only ProTaper Universal RFs D1–D3 were used, and the extruded debris was weighed. Groups 2, 3, and 4 were the experimental groups, receiving a twofold retreatment protocol: Removal of the bulk, followed by the use of supplementary files. The bulk was removed by RFs, followed by the use of ProTaper NEXT (PTN), WaveOne (WO), and Self-Adjusting File (SAF) for removal of the remaining root filling residues. Debris extruded apically were weighed and compared to the control group. Statistical analysis was performed using one-way analysis of variance (ANOVA) and post hoc Tukey's test. Results: All the three experimental groups presented significant difference (P < .01). The post hoc Tukey's test confirmed that Group 4 (SAF) exhibited significantly less (P < .01) debris extrusion between the three groups tested. Conclusion: SAF results in less extrusion of debris when used as supplementary file to remove root-filling residues, compared to WO and PTN. PMID:27099416
Root Canal Cleaning Efficacy of Rotary and Hand Files Instrumentation in Primary Molars
Nazari Moghaddam, Kiumars; Mehran, Majid; Farajian Zadeh, Hamideh
2009-01-01
INTRODUCTION: Pulpectomy of primary teeth is commonly carried out with hand files and broaches; a tricky and time consuming procedure. The purpose of this in vitro study was to compare the cleaning efficacy and time taken for instrumentation of deciduous molars using hand K-files and Flex Master rotary system. MATERIALS AND METHODS: In this study, 68 canals of 23 extracted primary molars with at least two third intact roots and 7-12 mm length were selected. After preparing an access cavity, K-file size #15 was introduced into the root canal and India ink was injected with an insulin syringe. Sixty samples were randomly divided in to experimental groups in group I (n=30), root canals were prepared with hand K-files; in group II (n=30), rotary Flex Master files were used for instrumentation, and in group III 8 remained samples were considered as negative controls. After clearing and root sectioning, the removal of India ink from cervical, middle, and apical thirds was scored. Data was analyzed using student's T-test and Mann-Whitney U test. RESULTS: There was no significant difference between experimental groups cleaning efficacy at the cervical, middle and apical root canal thirds. Only the coronal third scored higher in the hand instrumented group (P<0.001). Instrumentation with Flex Master rotary files was significantly less time consuming (P<0.001). CONCLUSION: Although there was no difference in cleanliness efficacy at the apical and middle thirds, the coronal third was more effectively cleaned with hand files. Predictably, time efficiency was a significant advantage with rotary technique. PMID:23940486
The Interface Theory of Perception.
Hoffman, Donald D; Singh, Manish; Prakash, Chetan
2015-12-01
Perception is a product of evolution. Our perceptual systems, like our limbs and livers, have been shaped by natural selection. The effects of selection on perception can be studied using evolutionary games and genetic algorithms. To this end, we define and classify perceptual strategies and allow them to compete in evolutionary games in a variety of worlds with a variety of fitness functions. We find that veridical perceptions--strategies tuned to the true structure of the world--are routinely dominated by nonveridical strategies tuned to fitness. Veridical perceptions escape extinction only if fitness varies monotonically with truth. Thus, a perceptual strategy favored by selection is best thought of not as a window on truth but as akin to a windows interface of a PC. Just as the color and shape of an icon for a text file do not entail that the text file itself has a color or shape, so also our perceptions of space-time and objects do not entail (by the Invention of Space-Time Theorem) that objective reality has the structure of space-time and objects. An interface serves to guide useful actions, not to resemble truth. Indeed, an interface hides the truth; for someone editing a paper or photo, seeing transistors and firmware is an irrelevant hindrance. For the perceptions of H. sapiens, space-time is the desktop and physical objects are the icons. Our perceptions of space-time and objects have been shaped by natural selection to hide the truth and guide adaptive behaviors. Perception is an adaptive interface.
Ramezanali, Fatemeh; Afkhami, Farzaneh; Soleimani, Ali; Kharrazifard, Mohammad Javad; Rafiee, Farshid
2015-01-01
Pulpectomy is the preferred treatment for restorable primary teeth with symptomatic irreversible pulpitis or periradicular lesion. Considering the rather new application of rotary files for pulpectomy of primary teeth, the aim of this study was to compare the cleaning efficacy and instrumentation time of hand K-files and Mtwo rotary system for preparation of human primary molars. This experimental study was conducted on 100 extracted primary maxillary and mandibular intact molars with no resorption. Access cavities were prepared and India ink was injected into the root canal on a vibrator using an insulin syringe. Canals were then divided into 5 groups (n=20): in group I, canals were instrumented using K-files up to #25 for mesial and buccal canals and #30 for palatal and distal canals. In group II, canals were prepared using Mtwo rotary files (15/0.05, 20/0.06 and 25/0.06 for mesial and buccal canals and 15/0.05, 20/0.06, 25/0.06 and finally 30/0.05 for distal and palatal canals). In group III, root canals were only irrigated with saline. Groups IV and V were the positive and negative control groups, respectively. The time required for cleaning and preparation of the canals for each of the specimens in groups I, II and III was recorded. The mean score of cleanliness of Mtwo was not significantly different from K-file group (P>0.05). However the mean instrumentation time in Mtwo group was significantly shorter (P<0.001). Although there were no differences regarding the cleaning efficacy of either system, Mtwo rotary files were far more time efficient.
[Shaping ability of multi-taper nickel-titanium files in simulated resin curved root canal].
Luo, Hong-Xia; Huang, Ding-Ming; Jia, Liu-He; Luo, Shi-Gao; Gao, Xiao-Jie; Tan, Hong; Zhou, Xue-Dong
2006-08-01
To compare the shaping ability of ISO standard stainless steel K files and multi-taper ProTaper nickel-titanium files in simulated resin curved root canals. METHODS Thirty simulated resin root canals were randomly divided into three groups and prepared by stainless steel K files, hand ProTaper, rotary ProTaper, respectively. The amount of material removed from inner and outer wall and canal width after canal preparation was measured, while the canal curvature before and after canal preparation and canals aberrations were recorded. The stainless steel K files removed more material than hand ProTaper and rotary ProTaper at the outer side of apex and inner side of curvature (P < 0.05). The mean degree of straightening in stainless steel K files group was significantly bigger than in ProTaper group (P < 0.05). The canals prepared by ProTaper had no evident aberration. The shaping ability of ProTaper is better than stainless steel K files.
Proposed color workflow solution from mobile and website to printing
NASA Astrophysics Data System (ADS)
Qiao, Mu; Wyse, Terry
2015-03-01
With the recent introduction of mobile devices and development in client side application technologies, there is an explosion of the parameter matrix for color management: hardware platform (computer vs. mobile), operating system (Windows, Mac OS, Android, iOS), client application (Flesh, IE, Firefox, Safari, Chrome), and file format (JPEG, TIFF, PDF of various versions). In a modern digital print shop, multiple print solutions are used: digital presses, wide format inkjet, dye sublimation inkjet are used to produce a wide variety of customizable products from photo book, personalized greeting card, canvas, mobile phone case and more. In this paper, we outline a strategy spans from client side application, print file construction, to color setup on printer to manage consistency and also achieve what-you-see-is-what-you-get for customers who are using a wide variety of technologies in viewing and ordering product.
Web-based healthcare hand drawing management system.
Hsieh, Sheau-Ling; Weng, Yung-Ching; Chen, Chi-Huang; Hsu, Kai-Ping; Lin, Jeng-Wei; Lai, Feipei
2010-01-01
The paper addresses Medical Hand Drawing Management System architecture and implementation. In the system, we developed four modules: hand drawing management module; patient medical records query module; hand drawing editing and upload module; hand drawing query module. The system adapts windows-based applications and encompasses web pages by ASP.NET hosting mechanism under web services platforms. The hand drawings implemented as files are stored in a FTP server. The file names with associated data, e.g. patient identification, drawing physician, access rights, etc. are reposited in a database. The modules can be conveniently embedded, integrated into any system. Therefore, the system possesses the hand drawing features to support daily medical operations, effectively improve healthcare qualities as well. Moreover, the system includes the printing capability to achieve a complete, computerized medical document process. In summary, the system allows web-based applications to facilitate the graphic processes for healthcare operations.
A computer program (MACPUMP) for interactive aquifer-test analysis
Day-Lewis, F. D.; Person, M.A.; Konikow, Leonard F.
1995-01-01
This report introduces MACPUMP (Version 1.0), an aquifer-test-analysis package for use with Macintosh4 computers. The report outlines the input- data format, describes the solutions encoded in the program, explains the menu-items, and offers a tutorial illustrating the use of the program. The package reads list-directed aquifer-test data from a file, plots the data to the screen, generates and plots type curves for several different test conditions, and allows mouse-controlled curve matching. MACPUMP features pull-down menus, a simple text viewer for displaying data-files, and optional on-line help windows. This version includes the analytical solutions for nonleaky and leaky confined aquifers, using both type curves and straight-line methods, and for the analysis of single-well slug tests using type curves. An executable version of the code and sample input data sets are included on an accompanying floppy disk.
Remote Environmental Monitoring and Diagnostics in the Perishables Supply Chain - Phase 1
2011-12-12
The table below displays the raw data from the tests. Each cell contains a number between 0 and 5 corresponding to the number of successful...along with the raw temperature data to the email addresses specified in the configuration file. As mentioned previously, for the CAEN...the Intelleflex system. The user also has the option to save the data log, which contains the raw temperature data, to a file on the Windows
NASA Technical Reports Server (NTRS)
Banks, David C.
1994-01-01
This talk features two simple and useful tools for digital image processing in the UNIX environment. They are xv and pbmplus. The xv image viewer which runs under the X window system reads images in a number of different file formats and writes them out in different formats. The view area supports a pop-up control panel. The 'algorithms' menu lets you blur an image. The xv control panel also activates the color editor which displays the image's color map (if one exists). The xv image viewer is available through the internet. The pbmplus package is a set of tools designed to perform image processing from within a UNIX shell. The acronym 'pbm' stands for portable bit map. Like xv, the pbm plus tool can convert images from and to many different file formats. The source code and manual pages for pbmplus are also available through the internet. This software is in the public domain.
FLASH Interface; a GUI for managing runtime parameters in FLASH simulations
NASA Astrophysics Data System (ADS)
Walker, Christopher; Tzeferacos, Petros; Weide, Klaus; Lamb, Donald; Flocke, Norbert; Feister, Scott
2017-10-01
We present FLASH Interface, a novel graphical user interface (GUI) for managing runtime parameters in simulations performed with the FLASH code. FLASH Interface supports full text search of available parameters; provides descriptions of each parameter's role and function; allows for the filtering of parameters based on categories; performs input validation; and maintains all comments and non-parameter information already present in existing parameter files. The GUI can be used to edit existing parameter files or generate new ones. FLASH Interface is open source and was implemented with the Electron framework, making it available on Mac OSX, Windows, and Linux operating systems. The new interface lowers the entry barrier for new FLASH users and provides an easy-to-use tool for experienced FLASH simulators. U.S. Department of Energy (DOE), NNSA ASC/Alliances Center for Astrophysical Thermonuclear Flashes, U.S. DOE NNSA ASC through the Argonne Institute for Computing in Science, U.S. National Science Foundation.
UniGene Tabulator: a full parser for the UniGene format.
Lenzi, Luca; Frabetti, Flavia; Facchin, Federica; Casadei, Raffaella; Vitale, Lorenza; Canaider, Silvia; Carinci, Paolo; Zannotti, Maria; Strippoli, Pierluigi
2006-10-15
UniGene Tabulator 1.0 provides a solution for full parsing of UniGene flat file format; it implements a structured graphical representation of each data field present in UniGene following import into a common database managing system usable in a personal computer. This database includes related tables for sequence, protein similarity, sequence-tagged site (STS) and transcript map interval (TXMAP) data, plus a summary table where each record represents a UniGene cluster. UniGene Tabulator enables full local management of UniGene data, allowing parsing, querying, indexing, retrieving, exporting and analysis of UniGene data in a relational database form, usable on Macintosh (OS X 10.3.9 or later) and Windows (2000, with service pack 4, XP, with service pack 2 or later) operating systems-based computers. The current release, including both the FileMaker runtime applications, is freely available at http://apollo11.isto.unibo.it/software/
Govindaraju, Lavanya; Jeevanandan, Ganesh; Subramanian, Emg
2017-09-01
Pulp therapy in primary teeth has been performed using various instrumentation techniques. However, the conventional instrumentation technique used for root canal preparation in primary teeth is hand instrumentation. Various Nickel-Titanium (Ni-Ti) instruments are available to perform efficient root canal preparation in primary teeth. These Ni-Ti instruments has been designed to aid in better root canal preparation in permanent teeth but are rarely used in primary teeth. It is necessary to assess the feasibility of using these adult rotary files with a modified sequence in primary teeth. To compare the quality of obturation and instrumentation time during root canal preparation using hand files and modified rotary file systems in primary molars. Forty-five primary mandibular molars were randomly assigned to three experimental groups (n=15). Group I was instrumented using k-hand files, Group II with S2 ProTaper universal file and Group III with 0.25 tip 4% taper K3 rotary file. Standardized digital radiographs were taken before and after root canal instrumentation. Root canal preparation time was also recorded. Statistical analysis of the obtained data was done using SPSS Software version 17.0. An intergroup comparison of the instrumentation time and the quality of obturation was done using ANOVA and Chi-square test with the level of significance set at 0.05. No significant differences were noted with regard to the quality of obturation (p=0.791). However, a statistically significant difference was noted in the instrumentation time between the three groups (p<0.05). ProTaper rotary system had significantly lesser instrumentation time when compared to that of K3 rotary system and hand file system. The hand files, S2 ProTaper Universal and K3 0.25 tip 4% taper files systems performed similarly with respect to the quality of obturation. There was a significant difference in instrumentation time with manual instrumentation compared to the modified rotary file systems in primary teeth.
Reddy, J M V Raghavendra; Latha, Prasanna; Gowda, Basavana; Manvikar, Varadendra; Vijayalaxmi, D Benal; Ponangi, Kalyana Chakravarthi
2014-02-01
Predictable successful endodontic therapy depends on correct diagnosis, effective cleaning, shaping and disinfection of the root canals and adequate obturation. Irrigation serves as a flush to remove debris, tissue solvent and lubricant from the canal irregularities; however these irregularities can restrict the complete debridement of root canal by mechanical instrumentation.Various types of hand and rotary instruments are used for the preparation of the root canal system to obtain debris free canals. The purpose of this study was to evaluate the amount of smear layer and debris removal on canal walls following the using of manual Nickel-Titanium (NiTi) files compared with rotary ProTaperNiTi files using a Scanning Electron Microscope in two individual groups. A comparative study consisting of 50 subjects randomized into two groups - 25 subjects in Group A (manual) and 25 subjects in Group B (rotary) was undertaken to investigate and compare the effects of smear layer and debris between manual and rotary NiTi instruments. Chi square test was used to find the significance of smear layer and debris removal in the coronal, middle and apical between Group A and Group B. Both systems of Rotary ProTaperNiTi and manual NiTi files used in the present study, did not create completely clean root canals. Manual NiTi files produced significantly less smear layer and debris compared to Rotary ProTaperNiTi instruments. Rotary instruments were less time consuming when compared to manual instruments. Instrument separation was not found to be significant with both the groups. Both systems of Rotary ProTaperNiTi and manual NiTi files used did not produce completely clean root canals. Manual NiTi files produced significantly less smear layer and debris compared to Rotary protaper instruments. How to cite the article: Reddy JM, Latha P, Gowda B, Manvikar V, Vijayalaxmi DB, Ponangi KC. Smear layer and debris removal using manual Ni-Ti files compared with rotary Protaper Ni-Ti files - An In-Vitro SEM study. J Int Oral Health 2014;6(1):89-94.
Reddy, J M V Raghavendra; Latha, Prasanna; Gowda, Basavana; Manvikar, Varadendra; Vijayalaxmi, D Benal; Ponangi, Kalyana Chakravarthi
2014-01-01
Background: Predictable successful endodontic therapy depends on correct diagnosis, effective cleaning, shaping and disinfection of the root canals and adequate obturation. Irrigation serves as a flush to remove debris, tissue solvent and lubricant from the canal irregularities; however these irregularities can restrict the complete debridement of root canal by mechanical instrumentation.Various types of hand and rotary instruments are used for the preparation of the root canal system to obtain debris free canals. The purpose of this study was to evaluate the amount of smear layer and debris removal on canal walls following the using of manual Nickel-Titanium (NiTi) files compared with rotary ProTaperNiTi files using a Scanning Electron Microscope in two individual groups. Materials & Methods: A comparative study consisting of 50 subjects randomized into two groups – 25 subjects in Group A (manual) and 25 subjects in Group B (rotary) was undertaken to investigate and compare the effects of smear layer and debris between manual and rotary NiTi instruments. Chi square test was used to find the significance of smear layer and debris removal in the coronal, middle and apical between Group A and Group B. Results: Both systems of Rotary ProTaperNiTi and manual NiTi files used in the present study, did not create completely clean root canals. Manual NiTi files produced significantly less smear layer and debris compared to Rotary ProTaperNiTi instruments. Rotary instruments were less time consuming when compared to manual instruments. Instrument separation was not found to be significant with both the groups. Conclusions: Both systems of Rotary ProTaperNiTi and manual NiTi files used did not produce completely clean root canals. Manual NiTi files produced significantly less smear layer and debris compared to Rotary protaper instruments. How to cite the article: Reddy JM, Latha P, Gowda B, Manvikar V, Vijayalaxmi DB, Ponangi KC. Smear layer and debris removal using manual Ni-Ti files compared with rotary Protaper Ni-Ti files - An In-Vitro SEM study. J Int Oral Health 2014;6(1):89-94. PMID:24653610
Bond-selective imaging of deep tissue through the optical window between 1600 and 1850 nm.
Wang, Pu; Wang, Han-Wei; Sturek, Michael; Cheng, Ji-Xin
2012-01-01
We report the employment of an optical window between 1600 nm and 1850 nm for bond-selective deep tissue imaging through harmonic vibrational excitation and acoustic detection of resultant pressure waves. In this window where a local minimum of water absorption resides, we found a 5 times enhancement of photoacoustic signal by first overtone excitation of the methylene group CH(2) at 1730 nm, compared to the second overtone excitation at 1210 nm. The enhancement allows 3D mapping of intramuscular fat with improved contrast and of lipid deposition inside an atherosclerotic artery wall in the presence of blood. Moreover, lipid and protein are differentiated based on the first overtone absorption profiles of CH(2) and methyl group CH(3) in this window. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Yu, Huajie; Qiu, Lixin
2017-10-01
Implant failures are more common when multiple missing posterior teeth need lateral sinus floor elevation owing to inadequate tissue maturation after grafting. Effects of lateral window dimensions on vital bone formation have rarely been compared. To compare endo-sinus bone formation between two- and solo-window techniques to rehabilitate multiple missing posterior teeth that need substantial augmentation. Patients with severely atrophic posterior maxilla were randomized to receive lateral sinus floor elevation via solo or two bony windows. Bone core specimens harvested from lateral aspect of the augmentation sites were histomorphometrically analyzed. Proportions of mineralized bone (MB), bone substitute materials (BS), and nonmineralized tissue (NMT) were quantified. Twenty-one patients underwent 23 maxillary sinus augmentations. One patient in each group dropped out during the follow-up period. Lateral window dimensions were 81.65 ± 4.59 and 118.04 ± 19.53 mm 2 in the test and control groups, respectively. Histomorphometric analysis revealed mean MB of 42.32% ± 13.07% and 26.00% ± 15.23%, BS of 40.34% ± 9.52% and 60.03% ± 10.13%, and NMT of 18.14% ± 14.24% and 14.75% ± 10.38% in test and control groups, respectively, with significant differences. The two-window technique could facilitate faster maturation and consolidation of the grafted volume and is an effective alternative for rehabilitation of severely atrophic posterior maxilla with multiple missing posterior teeth. © 2017 Wiley Periodicals, Inc.
25. SECOND FLOOR EAST SIDE APARTMENT KITCHEN INTERIOR SHOWING GROUP ...
25. SECOND FLOOR EAST SIDE APARTMENT KITCHEN INTERIOR SHOWING GROUP OF THREE 6-LIGHT WOOD-FRAME CASEMENT WINDOWS OVER THE SINK, AND OPEN DOORWAY TO TOP OF EXTERIOR STAIR LANDING AND WALKWAY AT REAR OF HOUSE. WALKWAY IS VISIBLE THROUGH KITCHEN WINDOWS. VIEW TO SOUTH. - Lee Vining Creek Hydroelectric System, Triplex Cottage, Lee Vining Creek, Lee Vining, Mono County, CA
SU-F-T-295: MLCs Performance and Patient-Specific IMRT QA Using Log File Analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Osman, A; American University of Biuret Medical Center, Biuret; Maalej, N
2016-06-15
Purpose: To analyze the performance of the multi-leaf collimators (MLCs) from the log files recorded during the intensity modulated radiotherapy (IMRT) treatment and to construct the relative fluence maps and do the gamma analysis to compare the planned and executed MLCs movement. Methods: We developed a program to extract and analyze the data from dynamic log files (dynalog files) generated from sliding window IMRT delivery treatments. The program extracts the planned and executed (actual or delivered) MLCs movement, calculates and compares the relative planned and executed fluences. The fluence maps were used to perform the gamma analysis (with 3% dosemore » difference and 3 mm distance to agreement) for 3 IMR patients. We compared our gamma analysis results with those obtained from portal dose image prediction (PDIP) algorithm performed using the EPID. Results: For 3 different IMRT patient treatments, the maximum difference between the planned and the executed MCLs positions was 1.2 mm. The gamma analysis results of the planned and delivered fluences were in good agreement with the gamma analysis from portal dosimetry. The maximum difference for number of pixels passing the gamma criteria (3%/3mm) was 0.19% with respect to portal dosimetry results. Conclusion: MLC log files can be used to verify the performance of the MLCs. Patientspecific IMRT QA based on MLC movement log files gives similar results to EPID dosimetry results. This promising method for patient-specific IMRT QA is fast, does not require dose measurements in a phantom, can be done before the treatment and for every fraction, and significantly reduces the IMRT workload. The author would like to thank King Fahd University of petroleum and Minerals for the support.« less
Cleaning efficacy of reciprocal and rotary systems in the removal of root canal filling material
Koçak, Mustafa Murat; Koçak, Sibel; Türker, Sevinç Aktemur; Sağlam, Baran Can
2016-01-01
Aim: The aim of this study was to compare the efficacy of hand file, nickel titanium rotary instrument, and two reciprocating instruments for removing gutta-percha and sealer from the root canals. Materials and Methods: Eighty-eight mandibular premolar teeth were used. The root canals were shaped and filled with gutta-percha and a resin-based sealer. The specimens were divided into four groups according to the technique by which the root filling material was removed: Group 1 — Wave One; Group 2 — Reciproc; Group 3 — ProTaper; and Group 4 — Gates-Glidden burs and stainless steel hand file. Then teeth were split longitudinally and photographed. The images were transferred to a computer. The ratio of remaining filling material to the root canal periphery was calculated with the aid of ImageJ software. Statistical analysis was performed using Kruskal–Wallis and Mann–Whitney tests. Results: A significant difference was found among all groups (P < 0.001). The WaveOne group demonstrated significantly less remaining filling material. The greatest amount of filling material was found in specimens where gutta-percha was removed with Gates-Glidden burs and stainless steel hand file. Conclusion: The reciprocating files were found to be significantly more effective in removing the filling material from the canal walls compared to the rotational file and hand file. PMID:27099429
Effects of self-adjusting file, Mtwo, and ProTaper on the root canal wall.
Hin, Ellemieke S; Wu, Min-Kai; Wesselink, Paul R; Shemesh, Hagay
2013-02-01
The purpose of this ex vivo study was to observe the incidence of cracks in root dentin after root canal preparation with hand files, self-adjusting file (SAF), ProTaper, and Mtwo. One hundred extracted mandibular premolars with single canals were randomly selected. Two angulated radiographs were taken for each tooth, and the width of the canal was measured at 9 mm from the apex. Five groups of 20 teeth each were comparable in canal width. The control group was left unprepared. Four experimental groups were instrumented with hand files, ProTaper, Mtwo, and SAF. Roots were then sectioned horizontally and observed under a microscope. The presence of dentinal cracks and their location were noted. The difference between the experimental groups was analyzed with a χ(2) test. No cracks were observed in the control group. In the experimental groups, ProTaper, Mtwo, and SAF caused cracks in 35%, 25%, and 10% of teeth, respectively. The hand-file group did not show any dentinal cracks (P < .0001). ProTaper and Mtwo caused more cracks than hand files (P < .05), but SAF did not (P > .05). Instrumentation of root canals with SAF, Mtwo, and ProTaper could cause damage to root canal dentin. SAF has a tendency to cause less dentinal cracks as compared with ProTaper or Mtwo. Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Early Detection | Division of Cancer Prevention
[[{"fid":"171","view_mode":"default","fields":{"format":"default","field_file_image_alt_text[und][0][value]":"Early Detection Research Group Homepage Logo","field_file_image_title_text[und][0][value]":"Early Detection Research Group Homepage Logo","field_folder[und]":"15"},"type":"media","field_deltas":{"1":{"format":"default","field_file_image_alt_text[und][0][value]":"Early
Shahi, Shahriar; Yavari, Hamid R; Rahimi, Saeed; Reyhani, Mohammad F; Kamarroosta, Zahra; Abdolrahimi, Majid
2009-03-01
The aim of this study was to evaluate the effect of RaCe, FlexMaster and ProFile rotary instruments on smear layer formation by scanning electron microscopy. Eighty-four caries-free freshly extracted human single-rooted teeth were selected and divided into three groups, each containing 28 teeth. The teeth were instrumented with rotary instruments sequentially: Group A: ProFile Rotary Instruments; Group B: FlexMaster Rotary Instruments; and Group C: RaCe Rotary Instruments. Instrumentation was performed by the crown-down method and according to the manufacturer's instructions. The specimens were then examined with SEM according to Hülsmann's classification. One-way ANOVA and a post hoc Tukey test were used for statistical analysis. The results showed that there were no statistically significant differences among the three groups in the coronal third (P = 0.39), but at the apical and middle thirds there were statistically significant differences between the RaCe group and the other groups (P < 0.05). Smear layer in the RaCe group was less than that in the ProFile and FlexMaster groups, but the difference between the ProFile group and FlexMaster group was not statistically significant (P > 0.05). It was concluded that RaCe Rotary Instruments produce less smear layer than FlexMaster and ProFile Rotary Instruments.
Karanovic, Marinko; Muffels, Christopher T.; Tonkin, Matthew J.; Hunt, Randall J.
2012-01-01
Models of environmental systems have become increasingly complex, incorporating increasingly large numbers of parameters in an effort to represent physical processes on a scale approaching that at which they occur in nature. Consequently, the inverse problem of parameter estimation (specifically, model calibration) and subsequent uncertainty analysis have become increasingly computation-intensive endeavors. Fortunately, advances in computing have made computational power equivalent to that of dozens to hundreds of desktop computers accessible through a variety of alternate means: modelers have various possibilities, ranging from traditional Local Area Networks (LANs) to cloud computing. Commonly used parameter estimation software is well suited to take advantage of the availability of such increased computing power. Unfortunately, logistical issues become increasingly important as an increasing number and variety of computers are brought to bear on the inverse problem. To facilitate efficient access to disparate computer resources, the PESTCommander program documented herein has been developed to provide a Graphical User Interface (GUI) that facilitates the management of model files ("file management") and remote launching and termination of "slave" computers across a distributed network of computers ("run management"). In version 1.0 described here, PESTCommander can access and ascertain resources across traditional Windows LANs: however, the architecture of PESTCommander has been developed with the intent that future releases will be able to access computing resources (1) via trusted domains established in Wide Area Networks (WANs) in multiple remote locations and (2) via heterogeneous networks of Windows- and Unix-based operating systems. The design of PESTCommander also makes it suitable for extension to other computational resources, such as those that are available via cloud computing. Version 1.0 of PESTCommander was developed primarily to work with the parameter estimation software PEST; the discussion presented in this report focuses on the use of the PESTCommander together with Parallel PEST. However, PESTCommander can be used with a wide variety of programs and models that require management, distribution, and cleanup of files before or after model execution. In addition to its use with the Parallel PEST program suite, discussion is also included in this report regarding the use of PESTCommander with the Global Run Manager GENIE, which was developed simultaneously with PESTCommander.
Control algorithms for dynamic windows for residential buildings
Firlag, Szymon; Yazdanian, Mehrangiz; Curcija, Charlie; ...
2015-09-30
This study analyzes the influence of control algorithms for dynamic windows on energy consumption, number of hours of retracted shades during daylight and shade operations. Five different control algorithms - heating/cooling, simple rules, perfect citizen, heat flow and predictive weather were developed and compared. The performance of a typical residential building was modeled with EnergyPlus. The program Widow was used to generate a Bi-Directional Distribution Function (BSDF) for two window configurations. The BSDF was exported to EnergyPlus using the IDF file format. The EMS feature in EnergyPlus was used to develop custom control algorithms. The calculations were made for fourmore » locations with diverse climate. The results showed that: (a) use of automated shading with proposed control algorithms can reduce the site energy in the range of 11.6-13.0%; in regard to source (primary) energy in the range of 20.1-21.6%, (b) the differences between algorithms in regard to energy savings are not high, (c) the differences between algorithms in regard to number of hours of retracted shades are visible, (e) the control algorithms have a strong influence on shade operation and oscillation of shade can occur, (d) additional energy consumption caused by motor, sensors and a small microprocessor in the analyzed case is very small.« less
Yılmaz, K; Uslu, G; Özyürek, T
2018-02-13
To compare the effect of autoclave cycles on the surface topography and roughness of HyFlex CM and HyFlex EDM instruments using atomic force microscopy (AFM) analysis. Eight new files of each brand were subdivided into four subgroups (n = 2/each subgroup). One group was allocated as the control group and not subjected to autoclave sterilization. The other three groups were subjected to different numbers (1, 5, and 10) of autoclave sterilization cycles. After the cycle instruments were subjected to AFM analysis. Roughness average (Ra) and the root mean square (RMS) values were chosen to investigate the surface features of endodontic files. The data was analyzed using one-way ANOVA and post hoc Tamhane tests at 5% significant level. The lowest Ra and RMS values were observed in the HyFlex EDM files that served as the control and in those subjected to a single cycle of autoclave sterilization (P < 0.05). The highest Ra and RMS values were observed in the HyFlex CM and HyFlex EDM files that were subjected to 10 cycles of autoclave sterilization (P < 0.05). The surface roughness values of the HyFlex CM group showed a significant increase after ten autoclave cycles, whereas those of the HyFlex EDM group exhibited a significant change after five autoclave cycles (P < 0.05). Although the initial surface roughness values of the HyFlex EDM files were lower than those of the HyFlex CM files, the surface roughness values of the EDM files showed a statistically significant increase after 5 cycles of autoclave sterilization. In contrast, the surface roughness values of the HyFlex CM files did not increase until 10 cycles of autoclave sterilization. Present study indicated that autoclave sterilization negatively affected the surface roughness of the tested NiTi files.
Topçuoğlu, H S; Düzgün, S; Akpek, F; Topçuoğlu, G; Aktı, A
2016-06-01
To evaluate the effect of a glide path on the amount of apically extruded debris during canal preparation using single-file systems in curved canals. Ninety extracted mandibular molar teeth were randomly assigned to six groups (n = 15 for each group) for canal instrumentation. Endodontic access cavities were prepared in each tooth. In three of the six groups, a glide path was not created whereas a glide path was created using PathFile instruments on the mesial canals of all teeth in the remaining three groups. The mesial canals of the teeth were then instrumented with the following single-file instrument systems: WaveOne, Reciproc and OneShape. Debris extruded apically during instrumentation was collected into pre-weighed Eppendorf tubes. The tubes were then stored in an incubator at 70 °C for 5 days. The weight of the dry extruded debris was established by subtracting the pre-instrumentation and post-instrumentation weight of the Eppendorf tubes for each group. The data obtained were analysed using one-way analysis of variance (anova) and Tukey's post hoc tests. The OneShape file was associated with less debris extrusion than the Reciproc and WaveOne files when canal instrumentation was performed without a glide path (P < 0.05). However, no significant difference was found between the Reciproc and WaveOne files (P > 0.05). There was no significant difference amongst the OneShape, Reciproc and WaveOne files when a glide path was created before canal preparation in curved root canals (P > 0.05). All systems extruded significantly less debris in groups with a glide path than in groups without a glide path (P < 0.05). All instruments were associated with apical extrusion of debris. Creating a glide path prior to canal instrumentation reduced the amount of apically extruded debris in curved canals. © 2015 International Endodontic Journal. Published by John Wiley & Sons Ltd.
Agarwal, Rolly S; Agarwal, Jatin; Jain, Pradeep; Chandra, Anil
2015-05-01
The ability of an endodontic instrument to remain centered in the root canal system is one of the most important characteristic influencing the clinical performance of a particular file system. Thus, it is important to assess the canal centering ability of newly introduced single file systems before they can be considered a viable replacement of full-sequence rotary file systems. The aim of the study was to compare the canal transportation, centering ability, and time taken for preparation of curved root canals after instrumentation with single file systems One Shape and Wave One, using cone-beam computed tomography (CBCT). Sixty mesiobuccal canals of mandibular molars with an angle of curvature ranging from 20(o) to 35(o) were divided into three groups of 20 samples each: ProTaper PT (group I) - full-sequence rotary control group, OneShape OS (group II)- single file continuous rotation, WaveOne WO - single file reciprocal motion (group III). Pre instrumentation and post instrumentation three-dimensional CBCT images were obtained from root cross-sections at 3mm, 6mm and 9mm from the apex. Scanned images were then accessed to determine canal transportation and centering ability. The data collected were evaluated using one-way analysis of variance (ANOVA) with Tukey's honestly significant difference test. It was observed that there were no differences in the magnitude of transportation between the rotary instruments (p >0.05) at both 3mm as well as 6mm from the apex. At 9 mm from the apex, Group I PT showed significantly higher mean canal transportation and lower centering ability (0.19±0.08 and 0.39±0.16), as compared to Group II OS (0.12±0.07 and 0.54±0.24) and Group III WO (0.13±0.06 and 0.55±0.18) while the differences between OS and WO were not statistically significant. It was concluded that there was minor difference between the tested groups. Single file systems demonstrated average canal transportation and centering ability comparable to full sequence Protaper system in curved root canals.
77 FR 55225 - Notice of Filing of Plats of Survey; Arizona
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-07
..., accepted August 20, 2012, and officially filed August 23, 2012, for Group 1090, Arizona. This plat was... 1090, Arizona. This plat was prepared at the request of the Bureau of Indian Affairs, Western Regional... filed August 23, 2012, for Group 1090, Arizona. This plat was prepared at the request of the Bureau of...
75 FR 20623 - Notice of Filing of Plats of Survey; Arizona
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-20
... 22 West, accepted March 23, 2010, and officially filed March 25, 2010, for Group 1060, Arizona. This... \\1/4\\ of section 12, Township 11 South, Range 25 West, accepted March 2, 2010, and officially filed March 4, 2010, for Group 9104, Arizona. This plat was prepared at the request of the Bureau of Land...
Geminiani, Alessandro; Weitz, Daniel S; Ercoli, Carlo; Feng, Changyong; Caton, Jack G; Papadimitriou, Dimitrios E V
2015-04-01
Sonic instruments may reduce perforation rates of the schneiderian membrane during lateral window sinus augmentation procedures. This study compares the incidence of membrane perforations using a sonic handpiece with an oscillating diamond insert versus a turbine handpiece with a conventional rotary diamond stone during lateral window sinus augmentation procedures. A retrospective chart analysis identified all lateral window sinus augmentation procedures done during a defined period. Among these procedures, those performed with a sonic handpiece and an oscillating diamond insert (experimental) and those performed with a conventional turbine and rotary diamond stone (conventional) were selected for this study. Reported occurrences of sinus membrane perforations during preparation of the osteotomy and elevation of the sinus membrane, as well as postoperative complications, were recorded and compared between treatment groups. Ninety-three consecutive patients were identified for a total of 130 sinus augmentation procedures (51 conventional, 79 experimental). Schneiderian membrane perforations were noted during preparation of the lateral window osteotomy in 27.5% of the sinuses in the conventional group and 12.7% of sinuses in the experimental group. During membrane elevation, perforations were noted in 43.1% of the sinuses in the conventional group and 25.3% of sinuses in the experimental group. Both differences in perforation rates were statistically significant (p < .05). There was no statistically significant difference in postoperative complications. In this study, the use of a sonic instrument to prepare the lateral window osteotomy during sinus elevation procedures resulted in a reduced perforation rate of the Schneiderian membrane compared with the conventional turbine instrument. © 2013 Wiley Periodicals, Inc.
AlShwaimi, E
2018-01-01
To compare the cyclic fatigue properties of a novel file made using controlled memory Ni-Ti technology with those of files made from M-wire. Twelve files with similar cross-sectional geometry and tip size from each of the following groups were tested: Proflexendo made from CMT (PE; size 30 0.04; Nexden, Houston, Tx, USA), ProFile Vortex made from M-wire (PV; size 30 0.04; Dentsply Tulsa Dental, Tulsa, OK, USA) and ProTaper Universal made from regular alloy (PU; F3; Dentsply Tulsa Dental). A custom-made cyclic fatigue device was made to evaluate the total number of cycles to failure for each system. A scanning electron microscope (SEM) was used to examine the fractured surfaces of the fragments. The arithmetic means and standard deviations were calculated for the total number of cycles to failure. One-way analysis of variance was used to compare the mean cyclic failure amongst the three groups. Post hoc Tukey's test was performed to compare the difference of the means between the groups at a significance level of P < 0.05. Proflexendo had a significantly greater resistance to cyclic fatigue compared to other systems (P < 0.001). Proflexendo files were able to withstand 500% more cycles to fracture when compared to ProFile Vortex files. Manufacturing technique had a significant impact on the resistance to cyclic fatigue. Proflexendo files made from controlled memory Ni-Ti technology had the highest number of cycles to failure compared to ProFile Vortex made from M-wire files with similar taper and tip size. © 2017 International Endodontic Journal. Published by John Wiley & Sons Ltd.
Zhong, Zhentao; Yu, Yue; Jin, Shufang; Pan, Jinming
2018-01-01
The hatch window that varies from 24 to 48 h is known to influence post-hatch performance of chicks. A narrow hatch window is needed for commercial poultry industry to acquire a high level of uniformity of chick quality. Hatching synchronization observed in avian species presents possibilities in altering hatch window in artificial incubation. Layer eggs which were laid on the same day by a single breeder flock and stored for no more than two days started incubation 12 h apart to obtain developmental distinction. The eggs of different initial incubation time were mixed as rows adjacent to rows on day 12 of incubation. During the hatching period (since day 18), hatching time of individual eggs and hatch window were obtained by video recordings. Embryonic development (day 18 and 20) and post-hatch performance up to day 7 were measured. The manipulation of mixing eggs of different initial incubation time shortened the hatch window of late incubated eggs in the manipulated group by delaying the onset of hatching process, and improved the hatchability. Compared to the control groups, chick embryos or chicks in the egg redistribution group showed no significant difference in embryonic development and post-hatch performance up to day 7. We have demonstrated that eggs that were incubated with advanced eggs performed a narrow spread of hatch with higher hatchability, normal embryonic development as well as unaffected chick quality. This specific manipulation is applicable in industrial poultry production to shorten hatch window and improve the uniformity of chick quality.
Biometry | Division of Cancer Prevention
[[{"fid":"66","view_mode":"default","fields":{"format":"default","field_file_image_alt_text[und][0][value]":"Biometry Research Group Homepage Logo","field_file_image_title_text[und][0][value]":"Biometry Research Group Homepage Logo","field_folder[und]":"15"},"type":"media","attributes":{"alt":"Biometry Research Group Homepage Logo","title":"Biometry Research Group Homepage
[Symptoms of sick house syndrome and contributory factors; study of general dwellings in Hokkaido].
Saijo, Yasuaki; Reiko, Kishi; Sata, Fumihiro; Katakura, Yoko; Urashima, Yukio; Hatakeyama, Akiko; Mukaihara, Norihiko; Kobayashi, Satoshi; Jin, Kazuo; Iikura, Yoji
2002-11-01
The aim of this study was to clarify the "Sick House Syndrome" which has recently received increasing attention, and to investigate relationships between symptoms and the state of general dwellings in Hokkaido. Questionnaires were sent to residents in 1775 dwellings, mainly solitary houses built or remodeled within the past few years by 24 construction companies in Sapporo and its environs, and answers was received from 564. The questionnaires included queries about building structure and characteristics, the residents' habits in the home, and subjective symptoms. We requested one resident who had the most severe symptoms in the dwelling to answer a questionnaire about symptoms. We classified the symptoms into 11 categories, and selected those that developed or were aggravated after the building or remodeling. We defined dwellings in which inhabitants complained of one or more categories of symptoms as the group with sick-house-related disease (developed or aggravated group: DA group), and those in which the inhabitants complained of two or more symptoms as the group with sick house syndrome (more than one organic symptom group: MO group)". Associations between symptoms and dwellings were then studied. There were 201 dwellings for which residents complained of symptoms (37.2%). Of these, 94 were in the DA group (16.7%), and 57 (10.1%) in the MO group. The symptoms that developed or were aggravated after building or remodeling of the dwellings were throat, 7.1%, dermal, 6.9%, psychoneural, 5.3%, eye, 5.1%, and nasal problems, 4.1%. Unpleasant odors form furniture were significant in both groups (DA: crude odds ratio (OR) 2.66, MO: OR 3.24). Use of aromatics was significant in group DA (OR 1.78). Condensation on windows and mold growth in the dwellings were significant in both groups (condensation on windows; DA: OR 2.98, MO: OR 3.32, mold growth; DA: OR 3.11, MO: OR 3.24). In addition, the percentage of dwellings for which residents complained of symptoms increased with signs of dampness (condensation on windows and mold growth). On logistic regression analysis, condensation on windows and mold growth were significant in both groups, and unpleasant odors from furniture in the MO group. It is suggested that symptoms of sick house syndrome are associated with high humidity such as condensation on windows and mold growth, odors from furniture and use of aromatics.
SNP_tools: A compact tool package for analysis and conversion of genotype data for MS-Excel
Chen, Bowang; Wilkening, Stefan; Drechsel, Marion; Hemminki, Kari
2009-01-01
Background Single nucleotide polymorphism (SNP) genotyping is a major activity in biomedical research. Scientists prefer to have a facile access to the results which may require conversions between data formats. First hand SNP data is often entered in or saved in the MS-Excel format, but this software lacks genetic and epidemiological related functions. A general tool to do basic genetic and epidemiological analysis and data conversion for MS-Excel is needed. Findings The SNP_tools package is prepared as an add-in for MS-Excel. The code is written in Visual Basic for Application, embedded in the Microsoft Office package. This add-in is an easy to use tool for users with basic computer knowledge (and requirements for basic statistical analysis). Conclusion Our implementation for Microsoft Excel 2000-2007 in Microsoft Windows 2000, XP, Vista and Windows 7 beta can handle files in different formats and converts them into other formats. It is a free software. PMID:19852806
SNP_tools: A compact tool package for analysis and conversion of genotype data for MS-Excel.
Chen, Bowang; Wilkening, Stefan; Drechsel, Marion; Hemminki, Kari
2009-10-23
Single nucleotide polymorphism (SNP) genotyping is a major activity in biomedical research. Scientists prefer to have a facile access to the results which may require conversions between data formats. First hand SNP data is often entered in or saved in the MS-Excel format, but this software lacks genetic and epidemiological related functions. A general tool to do basic genetic and epidemiological analysis and data conversion for MS-Excel is needed. The SNP_tools package is prepared as an add-in for MS-Excel. The code is written in Visual Basic for Application, embedded in the Microsoft Office package. This add-in is an easy to use tool for users with basic computer knowledge (and requirements for basic statistical analysis). Our implementation for Microsoft Excel 2000-2007 in Microsoft Windows 2000, XP, Vista and Windows 7 beta can handle files in different formats and converts them into other formats. It is a free software.
Govindaraju, Lavanya; Jeevanandan, Ganesh; Subramanian, E M G
2017-01-01
In permanent dentition, different rotary systems are used for canal cleaning and shaping. Rotary instrumentation in pediatric dentistry is an emerging concept. A very few studies have compared the efficiency of rotary instrumentation for canal preparation in primary teeth. Hence, this study was performed to compare the obturation quality and instrumentation time of two rotary files systems - Protaper, Mtwo with hand files in primary molars. Forty-five primary mandibular molars were randomly allotted to one of the three groups. Instrumentation was done using K-files in Group 1; Protaper in Group 2; and Mtwo in Group 3. Instrumentation time was recorded. The canal filling quality was assessed as underfill, optimal fill, and overfill. Statistical analysis was done using Chi-square, ANOVA, and post hoc Tukey test. No significant difference was observed in the quality of obturation among three groups. Intergroup comparison of the instrumentation time showed a statistically significant difference between the three groups. The use of rotary instrumentation in primary teeth results in marked reduction in the instrumentation time and improves the quality of obturation.
Govindaraju, Lavanya; Subramanian, EMG
2017-01-01
Introduction Pulp therapy in primary teeth has been performed using various instrumentation techniques. However, the conventional instrumentation technique used for root canal preparation in primary teeth is hand instrumentation. Various Nickel-Titanium (Ni-Ti) instruments are available to perform efficient root canal preparation in primary teeth. These Ni-Ti instruments has been designed to aid in better root canal preparation in permanent teeth but are rarely used in primary teeth. It is necessary to assess the feasibility of using these adult rotary files with a modified sequence in primary teeth. Aim To compare the quality of obturation and instrumentation time during root canal preparation using hand files and modified rotary file systems in primary molars. Materials and Methods Forty-five primary mandibular molars were randomly assigned to three experimental groups (n=15). Group I was instrumented using k-hand files, Group II with S2 ProTaper universal file and Group III with 0.25 tip 4% taper K3 rotary file. Standardized digital radiographs were taken before and after root canal instrumentation. Root canal preparation time was also recorded. Statistical analysis of the obtained data was done using SPSS Software version 17.0. An intergroup comparison of the instrumentation time and the quality of obturation was done using ANOVA and Chi-square test with the level of significance set at 0.05. Results No significant differences were noted with regard to the quality of obturation (p=0.791). However, a statistically significant difference was noted in the instrumentation time between the three groups (p<0.05). ProTaper rotary system had significantly lesser instrumentation time when compared to that of K3 rotary system and hand file system. Conclusion The hand files, S2 ProTaper Universal and K3 0.25 tip 4% taper files systems performed similarly with respect to the quality of obturation. There was a significant difference in instrumentation time with manual instrumentation compared to the modified rotary file systems in primary teeth. PMID:29207834
Zand, Vahid; Mokhtari, Hadi; Reyhani, Mohammad-Frough; Nahavandizadeh, Neda; Azimi, Shahram
2017-11-01
The aim of the present study was to compare the amount of the smear layer remaining in prepared root canals with different protocols of Bio RaCe files and XP-endo Finisher file (XPF) in association with 17% EDTA and sodium hypochlorite solution. A total of 68 extracted single-rooted teeth were randomly divided into 4 experimental groups (n=14) and two control groups (n=6). The root canals were prepared with Bio RaCe files (FKG Dentaire, Switzerland) using the crown-down technique based on manufacturer's instructions and irrigated according to the following irrigation techniques: Group 1: XPF with 2 mL of 2.5% NaOCl for 1 minute. Group 2:, XPF with 1 mL of 17% EDTA for one minute. Group 3: XPF was used for 1 minute in association with normal saline solution. Group 4: XP-endo Finisher file for 30 seconds in association with 2.5% NaOCl and 17% EDTA for 30 seconds. The negative control group: NaOCl (2.5%) was used during root canal preparation, followed by irrigation with 17% EDTA at the end of root canal preparation. The positive control group: Normal saline solution was used for irrigation during root canal preparation. In all the groups, during preparation of the root canals with Bio RaCe file, 20 mL of 2.5% NaOCl was used for root canal irrigation and at the end of the procedural steps 20 mL of normal saline solution was used as a final irrigant. The samples were analyzed under SEM at ×1000‒2000 magnification and evaluated using Torabinejad scoring system. Data were analyzed with non-parametric Kruskal-Wallis test and post hoc Mann-Whitney U test, using SPSS. Statistical significant was defined at P <0.05. The results of the study showed the least amount of the smear layer at coronal, middle and apical thirds of the root canals in groups 2, which was not significantly different from the negative control group ( P <0.5). Under the limitations of the present study, use of a combination of NaOCl and EDTA in association with XPF exhibited the best efficacy for the removal of the smear layer. Key words: Smear layer, XP-endo Finisher file, EDTA, Sodium hypochlorite.
Investigation on the Frequency Allocation for Radio Astronomy at the L Band
NASA Astrophysics Data System (ADS)
Abidin, Z. Z.; Umar, R.; Ibrahim, Z. A.; Rosli, Z.; Asanok, K.; Gasiprong, N.
2013-09-01
In this paper, the frequency allocation reserved for radio astronomy in the L band set by the International Telecommunication Union (ITU), which is between 1400 and 1427 MHz, is reviewed. We argue that the nearby frequencies are still very important for radio astronomers on the ground by investigating radio objects (H i sources) around 1300-1500 MHz. The L-band window is separated into a group of four windows, namely 1400-1427 MHz (window A), 1380-1400 MHz (window B), 1350-1380 MHz (window C), and 1300-1350 MHz (window D). These windows are selected according to their redshifts from a rest frequency for hydrogen spectral line at 1420.4057 MHz. Radio objects up to z ≈ 0.1 or frequency down to 1300 MHz are examined. We argue that since window B has important radio objects within the four windows, this window should also be given to radio astronomy. They are galaxies, spiral galaxies, and galaxy clusters. This underlines the significance of window B for radio astronomers on the ground. By investigating the severeness of radio frequency interference (RFI) within these windows, we have determined that window B still has significant, consistent RFI. The main RFI sources in the four windows have also been identified. We also found that the Department of Civil Aviation of Malaysia is assigned a frequency range of 1215-1427 MHz, which is transmitted within the four windows and inside the protected frequency for radio astronomy. We also investigated the RFI in the four windows on proposed sites of future radio astronomy observatories in Malaysia and Thailand and found the two best sites as Universiti Pendidikan Sultan Idris (UPSI) and Ubon Ratchathani, respectively. It has also been determined that RFI in window B increases with population density.
The effect of thermal treatment on the resistance of nickel-titanium rotary files in cyclic fatigue.
Zinelis, Spiros; Darabara, Myrsini; Takase, Toshiyuki; Ogane, Kaoru; Papadimitriou, George D
2007-06-01
The purpose of this study was to determine the effect of various thermal treatments on the fatigue resistance of a nickel-titanium (NiTi) engine-driven endodontic file. Fifteen groups of 5 files each of ISO 30 and taper .04 were tested in this study. The cutting tip (5 mm from the end) of files from 14 groups were heat treated for 30 minutes in temperatures 250 degrees C, 300 degrees C, 350 degrees C, 375 degrees C, 400 degrees C, 410 degrees C, 420 degrees C, 425 degrees C, 430 degrees C, 440 degrees C, 450 degrees C, 475 degrees C, 500 degrees C, and 550 degrees C, respectively, while 1 group was used as reference. The files were placed in a device that allowed the instruments to be tested for rotating bending fatigue inside an artificial root canal. The number of rotations to breakage was recorded for each file. The mean values of all groups were statistically analyzed using 1-way analysis of variance and Student Newman Keuls multiple comparison test at alpha = .05. The 430 degrees C and 440 degrees C groups showed the highest values, with fatigue resistance decreasing for thermal treatment at lower and higher temperatures. This may be the result of metallurgical changes during annealing. Within the limitations of the low sample size and the specific instrument size tested, it appears that the appropriate thermal treatment may significantly increase the fatigue resistance of the NiTi file tested.
A Job Monitoring and Accounting Tool for the LSF Batch System
NASA Astrophysics Data System (ADS)
Sarkar, Subir; Taneja, Sonia
2011-12-01
This paper presents a web based job monitoring and group-and-user accounting tool for the LSF Batch System. The user oriented job monitoring displays a simple and compact quasi real-time overview of the batch farm for both local and Grid jobs. For Grid jobs the Distinguished Name (DN) of the Grid users is shown. The overview monitor provides the most up-to-date status of a batch farm at any time. The accounting tool works with the LSF accounting log files. The accounting information is shown for a few pre-defined time periods by default. However, one can also compute the same information for any arbitrary time window. The tool already proved to be an extremely useful means to validate more extensive accounting tools available in the Grid world. Several sites have already been using the present tool and more sites running the LSF batch system have shown interest. We shall discuss the various aspects that make the tool essential for site administrators and end-users alike and outline the current status of development as well as future plans.
Virtualizing Resources for the Application Services and Framework Team
NASA Technical Reports Server (NTRS)
Varner, Justin T.; Crawford, Linda K.
2010-01-01
Virtualization is an emerging technology that will undoubtedly have a major impact on the future of Information Technology. It allows for the centralization of resources in an enterprise system without the need to make any changes to the host operating system, file system, or registry. In turn, this significantly reduces cost and administration, and provides a much greater level of security, compatibility, and efficiency. This experiment examined the practicality, methodology, challenges, and benefits of implementing the technology for the Launch Control System (LCS), and more specifically the Application Services (AS) group of the National Aeronautics and Space Administration (NASA) at the Kennedy Space Center (KSC). In order to carry out this experiment, I used several tools from the virtualization company known as VMWare; these programs included VMWare ThinApp, VMWare Workstation, and VMWare ACE. Used in conjunction, these utilities provided the engine necessary to virtualize and deploy applications in a desktop environment on any Windows platform available. The results clearly show that virtualization is a viable technology that can, when implemented properly, dramatically cut costs, enhance stability and security, and provide easier management for administrators.
Hammad, Mohammad; Qualtrough, Alison; Silikas, Nick
2008-11-01
The aim of this study was to measure the remaining filling volume of different obturation materials from root-filled extracted teeth by using 2 removal techniques. Eighty single-rooted teeth were collected and decoronated, and the root canal was prepared by using the ProTaper nickel-titanium rotary files. The teeth were randomly allocated into 4 groups, and each group was obturated by using a different material. Group 1 was filled with gutta-percha and TubliSeal sealer, group 2 was filled with EndoRez points and EndoRez sealer, group 3 was filled with RealSeal points and RealSeal sealer, and Group 4 was filled with a gutta-percha point and GuttaFlow sealer. Teeth were scanned with a micro-computed tomography scan, and then root fillings were removed by using ProTaper retreatment files or hand K-files. Teeth were scanned again, and volume measurements were carried out with micro-computed tomography software. Statistical analysis showed significant differences between the 2 removal techniques for gutta-percha and for both techniques between gutta-percha and the other groups. The present study showed that all tested filling materials were not completely removed during retreatment by using hand or rotary files. Gutta-percha was more efficiently removed by using hand K-files.
Code of Federal Regulations, 2011 CFR
2011-04-01
...) [ ] Group, in accordance with § 240.13d-1(b)(1)(ii)(K). If filing as a non-U.S. institution in accordance... § 240.13d-1(b)(1)(ii)(K) and a member of the group is a non-U.S. institution eligible to file pursuant... group (a) (see instructions) (b) (3) SEC use only (4) Citizenship or place of organization Number of...
Code of Federal Regulations, 2012 CFR
2012-04-01
...) [ ] Group, in accordance with § 240.13d-1(b)(1)(ii)(K). If filing as a non-U.S. institution in accordance... a member of the group is a non-U.S. institution eligible to file pursuant to § 240.13d-1(b)(1)(ii)(J... No.___ (1) Names of reporting persons (2) Check the appropriate box if a member of a group (a) (see...
Code of Federal Regulations, 2010 CFR
2010-04-01
...) [ ] Group, in accordance with § 240.13d-1(b)(1)(ii)(K). If filing as a non-U.S. institution in accordance... § 240.13d-1(b)(1)(ii)(K) and a member of the group is a non-U.S. institution eligible to file pursuant... No.___ (1) Names of reporting persons (2) Check the appropriate box if a member of a group (a) (see...
Code of Federal Regulations, 2013 CFR
2013-04-01
...) [ ] Group, in accordance with § 240.13d-1(b)(1)(ii)(K). If filing as a non-U.S. institution in accordance... a member of the group is a non-U.S. institution eligible to file pursuant to § 240.13d-1(b)(1)(ii)(J... No.___ (1) Names of reporting persons (2) Check the appropriate box if a member of a group (a) (see...
Code of Federal Regulations, 2014 CFR
2014-04-01
...) [ ] Group, in accordance with § 240.13d-1(b)(1)(ii)(K). If filing as a non-U.S. institution in accordance... a member of the group is a non-U.S. institution eligible to file pursuant to § 240.13d-1(b)(1)(ii)(J... No.___ (1) Names of reporting persons (2) Check the appropriate box if a member of a group (a) (see...
Tambe, Varsha Harshal; Nagmode, Pradnya Sunil; Abraham, Sathish; Patait, Mahendra; Lahoti, Pratik Vinod; Jaju, Neha
2014-01-01
Aim: The aim of the present study was to compare the canal transportation and centering ability of Rotary ProTaper, One Shape and Wave One systems using cone beam computed tomography (CBCT) in curved root canals to find better instrumentation technique for maintaining root canal geometry. Materials and Methods: Total 30 freshly extracted premolars having curved root canals with at least 10 degrees of curvature were divided into three groups of 10 teeth each. All teeth were scanned by CBCT to determine the root canal shape before instrumentation. In Group 1, the canals were prepared with Rotary ProTaper files, in Group 2 the canals were prepared with One Shape files and in Group 3 canals were prepared with Wave One files. After preparation, post-instrumentation scan was performed. Pre-instrumentation and post-instrumentation images were obtained at three levels, 3 mm apical, 3 mm coronal and 8 mm apical above the apical foramen were compared using CBCT software. Amount of transportation and centering ability were assessed. The three groups were statistically compared with analysis of variance and Tukey honestly significant. Results: All instruments maintained the original canal curvature with significant differences between the different files. Data suggested that Wave One files presented the best outcomes for both the variables evaluated. Wave One files caused lesser transportation and remained better centered in the canal than One Shape and Rotary ProTaper files. Conclusion: The canal preparation with Wave One files showed lesser transportation and better centering ability than One Shape and ProTaper. PMID:25506145
Vadhana, Sekar; SaravanaKarthikeyan, Balasubramanian; Nandini, Suresh; Velmurugan, Natanasabapathy
2014-07-01
The purpose of this study was to evaluate and compare the cyclic fatigue resistance of RaCe (FKG Dentaire, La Chaux-de-Fonds, Switzerland) and Mtwo (VDW, Munich, Germany) rotary files in continuous rotation and reciprocating motion. A total of 60 new rotary Mtwo and RaCe files (ISO size = 25, taper = 0.06, length = 25 mm) were selected and randomly divided into 4 groups (n = 15 each): Mtc (Mtwo NiTi files in continuous rotation), Rc (RaCe NiTi files in continuous rotation), Mtr (Mtwo NiTi files in reciprocating motion), and Rr (RaCe NiTi files in reciprocating motion). A cyclic fatigue testing device was fabricated with a 60° angle of curvature and a 5-mm radius. All instruments were rotated or reciprocated until fracture occurred. The time taken for each instrument to fracture and the length of the broken fragments were recorded. All the fractured files were analyzed under a scanning electron microscope to detect the mode of fracture. The Kolmogorov-Smirnov test was used to assess the normality of samples distribution, and statistical analysis was performed using the independent sample t test. The time taken for the instruments of the Mtr and Rr groups to fail under cyclic loading was significantly longer compared with the Mtc and Rc groups (P < .001). Scanning electron microscopic observations showed that the instruments of all groups had undergone a ductile mode of fracture. The length of the fractured segments was between 5 and 6 mm, which was not statistically significant among the experimental groups. Mtwo and RaCe rotary instruments showed a significantly higher cyclic fatigue resistance in reciprocating motion compared with continuous rotation motion. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
[In vitro study of shaping ability of single-file techniques in curved canals].
Zeng, Yajie; Gu, Lisha; Cai, Yanling; Chen, Dian; Wei, Xi
2014-11-01
To compare the shaping quality in curved canals of two single-file technique systems with other two traditional full-sequential systems. Eighty mature molar canals with the curvature between 20 and 45 degrees were randomly divided into four groups. Specimens in each group were prepared to size 25 at working length using A (Reciproc), B (OneShape), C (MTwo) and D (Revo S), respectively. Each canal was scanned by micro-computed tomography before and after preparation. Parameters including changes in dentine volume, percentage of uninstrumented area, degree and tendency of transportation were analyzed. The operating time was also recorded. In full canal length, there was no difference in canal dentine removal, instrumented percentage and transportation degree among four groups (P > 0.05). In the apical 4 mm region, group A removed more dentine [(2.14±0.76) mm(2) of canal surface area and (0.38 ± 0.15) mm(3) of canal volume] than groups B and C(P < 0.05). At 1 mm level, median of transportation degree of group A was 0.05 (0.03)mm, which was smaller than other groups (P < 0.05). Groups A and B took (86.3±24.6) s and (85.9±21.3) s, while groups C and D took (147.4±28.3) s and (126.3±27.7) s srespectively to finish preparation. Single file techniques were significantly faster than the two full-sequential systems (P < 0.01). Compared with the continuous rotary systems, the reciprocating single-file system A showed better apical shaping ability. Both single-file techniques were more efficient than full-sequential systems for curved canal preparation. Single-file techniques appear to be the effective and efficient method for curved canal preparation.
Jain, Niharika; Pawar, Ajinkya M.; Ukey, Piyush D.; Jain, Prashant K.; Thakur, Bhagyashree; Gupta, Abhishek
2017-01-01
Objectives: To compare the relative axis modification and canal concentricity after glide path preparation with 20/0.02 hand K-file (NITIFLEX®) and 20/0.04 rotary file (HyFlex™ CM) with subsequent instrumentation with 1.5 mm self-adjusting file (SAF). Materials and Methods: One hundred and twenty ISO 15, 0.02 taper, Endo Training Blocks (Dentsply Maillefer, Ballaigues, Switzerland) were acquired and randomly divided into following two groups (n = 60): group 1, establishing glide path till 20/0.02 hand K-file (NITIFLEX®) followed by instrumentation with 1.5 mm SAF; and Group 2, establishing glide path till 20/0.04 rotary file (HyFlex™ CM) followed by instrumentation with 1.5 mm SAF. Pre- and post-instrumentation digital images were processed with MATLAB R 2013 software to identify the central axis, and then superimposed using digital imaging software (Picasa 3.0 software, Google Inc., California, USA) taking five landmarks as reference points. Student's t-test for pairwise comparisons was applied with the level of significance set at 0.05. Results: Training blocks instrumented with 20/0.04 rotary file and SAF were associated less deviation in canal axis (at all the five marked points), representing better canal concentricity compared to those, in which glide path was established by 20/0.02 hand K-files followed by SAF instrumentation. Conclusion: Canal geometry is better maintained after SAF instrumentation with a prior glide path established with 20/0.04 rotary file. PMID:28855752
Khalap, Neha Deepak; Hegde, Vibha; Kokate, Sharad
2015-01-01
Aim: To compare the fracture resistance exhibited by teeth after primary endodontic treatment and retreatment. Materials and Methods: One hundred freshly extracted human teeth were selected. 20 samples served as control (untreated). Eighty experimental samples were divided into two groups (n = 40) for instrumentation using rotary Protaper NEXT (PTN) or reciprocating WaveOne (WO) files and obturated using warm lateral compaction. Half of the samples (n = 20) from each group were subjected to a load. The remaining half were subjected to retreatment using Protaper universal retreatment files (RFs) followed by a file larger than the master apical file used in groups 1 and 2 and reobturated. Group A: Control, Group B: PTN + obturation, Group C: WO + obturation, Group D: RF + PTN + obturation and Group E: RF + WO + obturation. The retreatment specimens were also subjected to load and the readings acquired were statistically analyzed. Result: When compared between the groups, control group exhibited the highest fracture resistance (P < 0.01). When multiple tests were performed, Group E exhibited significantly less fracture resistance (P < 0.01). Conclusion: Endodontic treatment and retreatment both results in lowering the fracture resistance of a tooth. PMID:26752838
Khalap, Neha Deepak; Hegde, Vibha; Kokate, Sharad
2015-01-01
To compare the fracture resistance exhibited by teeth after primary endodontic treatment and retreatment. One hundred freshly extracted human teeth were selected. 20 samples served as control (untreated). Eighty experimental samples were divided into two groups (n = 40) for instrumentation using rotary Protaper NEXT (PTN) or reciprocating WaveOne (WO) files and obturated using warm lateral compaction. Half of the samples (n = 20) from each group were subjected to a load. The remaining half were subjected to retreatment using Protaper universal retreatment files (RFs) followed by a file larger than the master apical file used in groups 1 and 2 and reobturated. Group A: Control, Group B: PTN + obturation, Group C: WO + obturation, Group D: RF + PTN + obturation and Group E: RF + WO + obturation. The retreatment specimens were also subjected to load and the readings acquired were statistically analyzed. When compared between the groups, control group exhibited the highest fracture resistance (P < 0.01). When multiple tests were performed, Group E exhibited significantly less fracture resistance (P < 0.01). Endodontic treatment and retreatment both results in lowering the fracture resistance of a tooth.
NASA Astrophysics Data System (ADS)
Chang, C.; Li, M.; Yeh, G.
2010-12-01
The BIOGEOCHEM numerical model (Yeh and Fang, 2002; Fang et al., 2003) was developed with FORTRAN for simulating reaction-based geochemical and biochemical processes with mixed equilibrium and kinetic reactions in batch systems. A complete suite of reactions including aqueous complexation, adsorption/desorption, ion-exchange, redox, precipitation/dissolution, acid-base reactions, and microbial mediated reactions were embodied in this unique modeling tool. Any reaction can be treated as fast/equilibrium or slow/kinetic reaction. An equilibrium reaction is modeled with an implicit finite rate governed by a mass action equilibrium equation or by a user-specified algebraic equation. A kinetic reaction is modeled with an explicit finite rate with an elementary rate, microbial mediated enzymatic kinetics, or a user-specified rate equation. None of the existing models has encompassed this wide array of scopes. To ease the input/output learning curve using the unique feature of BIOGEOCHEM, an interactive graphic user interface was developed with the Microsoft Visual Studio and .Net tools. Several user-friendly features, such as pop-up help windows, typo warning messages, and on-screen input hints, were implemented, which are robust. All input data can be real-time viewed and automated to conform with the input file format of BIOGEOCHEM. A post-processor for graphic visualizations of simulated results was also embedded for immediate demonstrations. By following data input windows step by step, errorless BIOGEOCHEM input files can be created even if users have little prior experiences in FORTRAN. With this user-friendly interface, the time effort to conduct simulations with BIOGEOCHEM can be greatly reduced.
Garaizar, Pablo; Reips, Ulf-Dietrich
2015-09-01
DMDX is a software package for the experimental control and timing of stimulus display for Microsoft Windows systems. DMDX is reliable, flexible, millisecond accurate, and can be downloaded free of charge; therefore it has become very popular among experimental researchers. However, setting up a DMDX-based experiment is burdensome because of its command-based interface. Further, DMDX relies on RTF files in which parts of the stimuli, design, and procedure of an experiment are defined in a complicated (DMASTR-compatible) syntax. Other experiment software, such as E-Prime, Psychopy, and WEXTOR, became successful as a result of integrated visual authoring tools. Such an intuitive interface was lacking for DMDX. We therefore created and present here Visual DMDX (http://visualdmdx.com/), a HTML5-based web interface to set up experiments and export them to DMDX item files format in RTF. Visual DMDX offers most of the features available from the rich DMDX/DMASTR syntax, and it is a useful tool to support researchers who are new to DMDX. Both old and modern versions of DMDX syntax are supported. Further, with Visual DMDX, we go beyond DMDX by having added export to JSON (a versatile web format), easy backup, and a preview option for experiments. In two examples, one experiment each on lexical decision making and affective priming, we explain in a step-by-step fashion how to create experiments using Visual DMDX. We release Visual DMDX under an open-source license to foster collaboration in its continuous improvement.
Visual tool for estimating the fractal dimension of images
NASA Astrophysics Data System (ADS)
Grossu, I. V.; Besliu, C.; Rusu, M. V.; Jipa, Al.; Bordeianu, C. C.; Felea, D.
2009-10-01
This work presents a new Visual Basic 6.0 application for estimating the fractal dimension of images, based on an optimized version of the box-counting algorithm. Following the attempt to separate the real information from "noise", we considered also the family of all band-pass filters with the same band-width (specified as parameter). The fractal dimension can be thus represented as a function of the pixel color code. The program was used for the study of paintings cracks, as an additional tool which can help the critic to decide if an artistic work is original or not. Program summaryProgram title: Fractal Analysis v01 Catalogue identifier: AEEG_v1_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/AEEG_v1_0.html Program obtainable from: CPC Program Library, Queen's University, Belfast, N. Ireland Licensing provisions: Standard CPC licence, http://cpc.cs.qub.ac.uk/licence/licence.html No. of lines in distributed program, including test data, etc.: 29 690 No. of bytes in distributed program, including test data, etc.: 4 967 319 Distribution format: tar.gz Programming language: MS Visual Basic 6.0 Computer: PC Operating system: MS Windows 98 or later RAM: 30M Classification: 14 Nature of problem: Estimating the fractal dimension of images. Solution method: Optimized implementation of the box-counting algorithm. Use of a band-pass filter for separating the real information from "noise". User friendly graphical interface. Restrictions: Although various file-types can be used, the application was mainly conceived for the 8-bit grayscale, windows bitmap file format. Running time: In a first approximation, the algorithm is linear.
Giuliani, Valentina; Cocchetti, Roberto; Pagavino, Gabriella
2008-11-01
The aim of this study was to evaluate the efficacy of the ProTaper Universal System rotary retreatment system and of Profile 0.06 and hand instruments (K-file) in the removal of root filling materials. Forty-two extracted single-rooted anterior teeth were selected. The root canals were enlarged with nickel-titanium (NiTi) rotary files, filled with gutta-percha and sealer, and randomly divided into 3 experimental groups. The filling materials were removed with solvent in conjunction with one of the following devices and techniques: the ProTaper Universal System for retreatment, ProFile 0.06, and hand instruments (K-file). The roots were longitudinally sectioned, and the image of the root surface was photographed. The images were captured in JPEG format; the areas of the remaining filling materials and the time required for removing the gutta-percha and sealer were calculated by using the nonparametric one-way Kruskal-Wallis test and Tukey-Kramer tests, respectively. The group that showed better results for removing filling materials was the ProTaper Universal System for retreatment files, whereas the group of ProFile rotary instruments yielded better root canal cleanliness than the hand instruments, even though there was no statistically significant difference. The ProTaper Universal System for retreatment and ProFile rotary instruments worked significantly faster than the K-file. The ProTaper Universal System for retreatment files left cleaner root canal walls than the K-file hand instruments and the ProFile Rotary instruments, although none of the devices used guaranteed complete removal of the filling materials. The rotary NiTi system proved to be faster than hand instruments in removing root filling materials.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-16
... SECURITIES AND EXCHANGE COMMISSION [File No. 500-1] AIMS Worldwide, Inc., Apollo Capital Group, Inc., CommunitySouth Financial Corp., Last Mile Logistics Group, Inc., Made in America Entertainment... concerning the securities of Last Mile Logistics Group, Inc. because it has not filed any periodic reports...
Montironi, R; Thompson, D; Scarpelli, M; Bartels, H G; Hamilton, P W; Da Silva, V D; Sakr, W A; Weyn, B; Van Daele, A; Bartels, P H
2002-01-01
Objective: To describe practical experiences in the sharing of very large digital data bases of histopathological imagery via the Internet, by investigators working in Europe, North America, and South America. Materials: Experiences derived from medium power (sampling density 2.4 pixels/μm) and high power (6 pixels/μm) imagery of prostatic tissues, skin shave biopsies, breast lesions, endometrial sections, and colonic lesions. Most of the data included in this paper were from prostate. In particular, 1168 histological images of normal prostate, high grade prostatic intraepithelial neoplasia (PIN), and prostate cancer (PCa) were recorded, archived in an image format developed at the Optical Sciences Center (OSC), University of Arizona, and transmitted to Ancona, Italy, as JPEG (joint photographic experts group) files. Images were downloaded for review using the Internet application FTP (file transfer protocol). The images were then sent from Ancona to other laboratories for additional histopathological review and quantitative analyses. They were viewed using Adobe Photoshop, Paint Shop Pro, and Imaging for Windows. For karyometric analysis full resolution imagery was used, whereas histometric analyses were carried out on JPEG imagery also. Results: The three applications of the telecommunication system were remote histopathological assessment, remote data acquisition, and selection of material. Typical data volumes for each project ranged from 120 megabytes to one gigabyte, and transmission times were usually less than one hour. There were only negligible transmission errors, and no problem in efficient communication, although real time communication was an exception, because of the time zone differences. As far as the remote histopathological assessment of the prostate was concerned, agreement between the pathologist's electronic diagnosis and the diagnostic label applied to the images by the recording scientist was present in 96.6% of instances. When these images were forwarded to two pathologists, the level of concordance with the reviewing pathologist who originally downloaded the files from Tucson was as high as 97.2% and 98.0%. Initial results of studies made by researchers belonging to our group but located in others laboratories showed the feasibility of making quantitative analysis on the same images. Conclusions: These experiences show that diagnostic teleconsultation and quantitative image analyses via the Internet are not only feasible, but practical, and allow a close collaboration between researchers widely separated by geographical distance and analytical resources. PMID:12037030
Topçuoğlu, Hüseyin Sinan; Düzgün, Salih; Kesim, Bertan; Tuncay, Oznur
2014-07-01
The aim of this study was to determine the incidence of crack initiation and propagation in apical root dentin after retreatment procedures performed by using 2 rotary retreatment systems and hand files with additional instrumentation. Eighty extracted mandibular premolars with single canals were selected. One millimeter from the apex of each tooth was ground perpendicular to the long axis of the tooth, and the apical surface was polished. Twenty teeth served as the control group, and no preparation was performed. The remaining 60 teeth were prepared to size 35 with rotary files and filled with gutta-percha and AH Plus sealer. Specimens were then divided into 3 groups (n = 20), and retreatment procedures were performed with the following devices and techniques: ProTaper Universal retreatment files, Mtwo retreatment files, and hand files. After retreatment, the additional instrumentation was performed by using size 40 ProTaper, Mtwo, and hand files. Digital images of the apical root surface were recorded before preparation, after instrumentation, after filling, after retreatment, and after additional instrumentation. The images were then inspected for the presence of any new apical cracks and propagation. Data were analyzed with the logistic regression and Fisher exact tests. All experimental groups caused crack initiation and propagation after use of retreatment instruments. The ProTaper and Mtwo retreatment groups caused greater crack initiation and propagation than the hand instrument group (P < .05) after retreatment. Additional instrumentation with ProTaper and Mtwo instruments after the use of retreatment instruments caused crack initiation and propagation, whereas hand files caused neither crack initiation nor propagation (P < .05). This study showed that retreatment procedures and additional instrumentation after the use of retreatment files may cause crack initiation and propagation in apical dentin. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Takahashi, R; Kamima, T; Tachibana, H
2016-06-15
Purpose: To investigate the effect of the trajectory files from linear accelerator for Clarkson-based independent dose verification in IMRT and VMAT plans. Methods: A CT-based independent dose verification software (Simple MU Analysis: SMU, Triangle Products, Japan) with a Clarksonbased algorithm was modified to calculate dose using the trajectory log files. Eclipse with the three techniques of step and shoot (SS), sliding window (SW) and Rapid Arc (RA) was used as treatment planning system (TPS). In this study, clinically approved IMRT and VMAT plans for prostate and head and neck (HN) at two institutions were retrospectively analyzed to assess the dosemore » deviation between DICOM-RT plan (PL) and trajectory log file (TJ). An additional analysis was performed to evaluate MLC error detection capability of SMU when the trajectory log files was modified by adding systematic errors (0.2, 0.5, 1.0 mm) and random errors (5, 10, 30 mm) to actual MLC position. Results: The dose deviations for prostate and HN in the two sites were 0.0% and 0.0% in SS, 0.1±0.0%, 0.1±0.1% in SW and 0.6±0.5%, 0.7±0.9% in RA, respectively. The MLC error detection capability shows the plans for HN IMRT were the most sensitive and 0.2 mm of systematic error affected 0.7% dose deviation on average. Effect of the MLC random error did not affect dose error. Conclusion: The use of trajectory log files including actual information of MLC location, gantry angle, etc should be more effective for an independent verification. The tolerance level for the secondary check using the trajectory file may be similar to that of the verification using DICOM-RT plan file. From the view of the resolution of MLC positional error detection, the secondary check could detect the MLC position error corresponding to the treatment sites and techniques. This research is partially supported by Japan Agency for Medical Research and Development (AMED)« less
Zhou, Ruokun; Tseng, Chiao-Li; Huan, Tao; Li, Liang
2014-05-20
A chemical isotope labeling or isotope coded derivatization (ICD) metabolomics platform uses a chemical derivatization method to introduce a mass tag to all of the metabolites having a common functional group (e.g., amine), followed by LC-MS analysis of the labeled metabolites. To apply this platform to metabolomics studies involving quantitative analysis of different groups of samples, automated data processing is required. Herein, we report a data processing method based on the use of a mass spectral feature unique to the chemical labeling approach, i.e., any differential-isotope-labeled metabolites are detected as peak pairs with a fixed mass difference in a mass spectrum. A software tool, IsoMS, has been developed to process the raw data generated from one or multiple LC-MS runs by peak picking, peak pairing, peak-pair filtering, and peak-pair intensity ratio calculation. The same peak pairs detected from multiple samples are then aligned to produce a CSV file that contains the metabolite information and peak ratios relative to a control (e.g., a pooled sample). This file can be readily exported for further data and statistical analysis, which is illustrated in an example of comparing the metabolomes of human urine samples collected before and after drinking coffee. To demonstrate that this method is reliable for data processing, five (13)C2-/(12)C2-dansyl labeled metabolite standards were analyzed by LC-MS. IsoMS was able to detect these metabolites correctly. In addition, in the analysis of a (13)C2-/(12)C2-dansyl labeled human urine, IsoMS detected 2044 peak pairs, and manual inspection of these peak pairs found 90 false peak pairs, representing a false positive rate of 4.4%. IsoMS for Windows running R is freely available for noncommercial use from www.mycompoundid.org/IsoMS.
Farhad Mollashahi, Narges; Sohrabi, Mahdi; Farhad Mollashahi, Leila; Mehdizadeh, Mojdeh
2014-01-01
An overlooked but important part of successful root canal treatment is a straight-line access (SLA). The purpose of this in vitro study was to compare the efficacy of IntroFile and PreRaCe rotary instruments with Gates Glidden (GG) drills in gaining SLA by cone-beam computed tomography (CBCT). A total of forty five extracted mandibular first molars were selected and mounted in dental like arches. Subsequently, they were randomly classified into three groups (n=15). After preparation of a standard access cavity, orifices of the mesiobuccal canal was reached and a #10 file was inserted to explore the canals until the file tip was visible at the apex. Then, preoperative CBCT images were taken. SLA was gained in three groups; group 1, FlexMaster's IntroFile (FM); group 2, PreRaCe (RC) and group 3, GG. Again, the first binding file at the working length (WL) was placed in the canal and postoperative CBCT images in similar positions were taken. The pre/post operative morphology of the canal was evaluated for changes. Data was analyzed using the one-way ANOVA and post-hoc Bonferroni analysis. The average amount of reduction in coronal canal curvature in FM, RC and GG groups was 2.43±1.79, 3.17±2.05 and 8.7±3.45, respectively. This descending trend was statistically significant. The difference between pre/post SLA changes in FM and RC groups was significant compared to GG group, while there were no significant differences between RC and FM. GG drills produced extraordinary results in reducing coronal curvature of the canal and achieving SLA. They are also more effective than nickel-titanium (NiTi) rotary instruments in canals with coronal curvature.
Ghogre, Priyanka; Chourasia, Hemant Ramesh; Agarwal, Manish; Singh, M P; Gurav, Sandeep; Ghogre, Rahul
2015-01-01
The aim of this study was to evaluate the number of intracanal bacteria extruded apically during root canal preparation using rotary ProTaper, K3XF, twisted, and hand K-file system. Seventy extracted single-rooted human mandibular premolar teeth were used. Access cavities were prepared and the teeth were mounted in glass vials. Root canals were then contaminated with a pure culture of Enterococcus faecalis (ATCC 29212) and incubated at 37°C for 24 h. The contaminated roots were divided into four experimental groups of 15 teeth each and one control group of 10 teeth. Group 1: ProTaper; Group 2: K3XF; Group 3: Twisted file; Group 4: Hand K-file; Group 5: Control group. Bacteria extruded from the apical foramen during instrumentation were collected into vials. The microbiological samples were incubated in culture media for 24 h. Colonies of bacteria were counted and the results were given as number of colony-forming units (CFU)/ml. The obtained data were analyzed using the Kruskal-Wallis one-way analysis of variance and Mann-Whitney U-tests. There was a significant difference between the rotary and hand instrumentation system related to the apically extruded intracanal bacteria. Both the rotary and hand instrumentation systems extruded intracanal bacteria through the apical foramen. K3XF file system showed least bacterial extrusion amongst all instrumentation groups.
Nazari, Shahrzad; MirMotalebi, Farshid
2006-01-01
INTRODUCTION: The purpose of the present study was to quantify and compare the amount of extruded debris from apical foramen after instrumentation of the root canal system with hand and rotary instruments. MATERIALS AND METHODS: Root canals of forty five fresh extracted single rooted human teeth with mature apexes and less than 15 degree of root curvature were instrumented in group A with stainless steel K-Type files, in group B with rotary NiTi Flex Master files, and in group C with rotary NiTi ProTaper files and followed weighting the extruded debris by a digital scale to within 0.0001 gram accuracy. RESULTS: In all groups, the mean weight of extruded debris was not more than 5 mg (P=0.0l) and was ranked as: Group A>Group B>Group C. There were statistically significant differences among three groups (p=0.0l). The mean value of extruded debris in the ProTaper and Flex Master groups were 0.652 and 0.788 mg, respectively. CONCLUSION: The study revealed that the amount of extruded debris from the apical foramen was minimal when ProTaper files were used. PMID:24470804
Agarwal, Jatin; Jain, Pradeep; Chandra, Anil
2015-01-01
Background The ability of an endodontic instrument to remain centered in the root canal system is one of the most important characteristic influencing the clinical performance of a particular file system. Thus, it is important to assess the canal centering ability of newly introduced single file systems before they can be considered a viable replacement of full-sequence rotary file systems. Aim The aim of the study was to compare the canal transportation, centering ability, and time taken for preparation of curved root canals after instrumentation with single file systems One Shape and Wave One, using cone-beam computed tomography (CBCT). Materials and Methods Sixty mesiobuccal canals of mandibular molars with an angle of curvature ranging from 20o to 35o were divided into three groups of 20 samples each: ProTaper PT (group I) – full-sequence rotary control group, OneShape OS (group II)- single file continuous rotation, WaveOne WO – single file reciprocal motion (group III). Pre instrumentation and post instrumentation three-dimensional CBCT images were obtained from root cross-sections at 3mm, 6mm and 9mm from the apex. Scanned images were then accessed to determine canal transportation and centering ability. The data collected were evaluated using one-way analysis of variance (ANOVA) with Tukey’s honestly significant difference test. Results It was observed that there were no differences in the magnitude of transportation between the rotary instruments (p >0.05) at both 3mm as well as 6mm from the apex. At 9 mm from the apex, Group I PT showed significantly higher mean canal transportation and lower centering ability (0.19±0.08 and 0.39±0.16), as compared to Group II OS (0.12±0.07 and 0.54±0.24) and Group III WO (0.13±0.06 and 0.55±0.18) while the differences between OS and WO were not statistically significant Conclusion It was concluded that there was minor difference between the tested groups. Single file systems demonstrated average canal transportation and centering ability comparable to full sequence Protaper system in curved root canals. PMID:26155551
Cancer Biomarkers | Division of Cancer Prevention
[[{"fid":"175","view_mode":"default","fields":{"format":"default","field_file_image_alt_text[und][0][value]":"Cancer Biomarkers Research Group Homepage Logo","field_file_image_title_text[und][0][value]":"Cancer Biomarkers Research Group Homepage Logo","field_folder[und]":"15"},"type":"media","attributes":{"alt":"Cancer Biomarkers Research Group Homepage Logo","title":"Cancer
Mori, Shinichiro; Karube, Masataka; Yasuda, Shigeo; Yamamoto, Naoyoshi; Tsuji, Hiroshi; Kamada, Tadashi
2017-06-01
To explore the trade-off between dose assessment and imaging dose in respiratory gating with radiographic fluoroscopic imaging, we evaluated the relationship between dose assessment and fluoroscopic imaging dose in various gating windows, retrospectively. Four-dimensional (4D) CT images acquired for 10 patients with lung and liver tumours were used for 4D treatment planning for scanned carbon ion beam. Imaging dose from two oblique directions was calculated by the number of images multiplied by the air kerma per image. Necessary beam-on time was calculated from the treatment log file. Accumulated dose distribution was calculated. The gating window was defined as tumour position not respiratory phase and changed from 0-100% duty cycle on 4DCT. These metrics were individually evaluated for every case. For lung cases, sufficient dose conformation was achieved in respective gating windows [D 95 -clinical target volume (CTV) > 99%]. V 20 -lung values for 50%- and 30%-duty cycles were 2.5% and 6.0% of that for 100%-duty cycle. Maximum doses (cord/oesophagus) for 30%-duty cycle decreased 6.8%/7.4% to those for 100%-duty cycle. For liver cases, V 10 -liver values for 50%- and 30%-duty cycles were 9.4% and 12.8% of those for 100%-duty cycle, respectively. Maximum doses (cord/oesophagus) for 50%- and 30%-duty cycles also decreased 17.2%/19.3% and 24.6%/29.8% to those for 100%-duty cycle, respectively. Total imaging doses increased 43.5% and 115.8% for 50%- and 30%-duty cycles to that for the 100%-duty cycle. When normal tissue doses are below the tolerance level, the gating window should be expanded to minimize imaging dose and treatment time. Advances in knowledge: The skin dose from imaging might not be counterbalanced to the OAR dose; however, imaging dose is a particularly important factor.
Muon catalyzed fusion beam window mechanical strength testing and analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ware, A.G.; Zabriskie, J.M.
A thin aluminum window (0.127 mm (0.005-inch) thick x 146 mm (5 3/4-inch) diameter) of 2024-T6 alloy was modeled and analyzed using the ABAQUS non-linear finite element analysis code. A group of windows was fabricated, heat-treated and subsequently tested. Testing included both ultimate burst pressure and fatigue. Fatigue testing cycles involved ''oil-canning'' behavior representing vacuum purge and reversal to pressure. Test results are compared to predictions and the mode of failure is discussed. Operational requirements, based on the above analysis and correlational testing, for the actual beam windows are discussed. 1 ref., 3 figs.
2011-04-01
this limitation the length of the windows needs to be shortened. It is also leads to a narrower confidence interval, see Figure 2.9. 82 The " big ...least one event will occur within the window. The windows are then grouped in sets of two and the process is reapeated for a window size twice as big ...0 505 T. Fu 1 506 D. Walden 1 508 J. Brown 1 55 T.Applebee 0 55 M. Dipper 1 551 T. Smith I 551 C. Bassler 3 3 551 V. Belenky 1 551 W. Belknap
VizieR Online Data Catalog: Herschel nearby isolated low-mass clouds maps (Sadavoy+, 2018)
NASA Astrophysics Data System (ADS)
Sadavoy, S. I.; Keto, E.; Bourke, T. L.; Dunham, M. M.; Myers, P. C.; Stephens, I. W.; di, Francesco J.; Webb, K.; Stutz, A. M.; Launhardt, R.; Tobin, J. J.
2018-05-01
For all the sources listed in table1, maps of dust temperature and optical depth at 353GHz for all globules as fits files. For all the sources listed in table1, maps of dust temperature, optical depth at 353GHz, and corrected Herschel intensities are available as fits files. The intensity maps contain labels to indicate the reliability of their intensity corrections with Group A as the most reliable, Group B as somewhat reliable, and Group C as least reliable. See paper for details. (3 data files).
Mousavi, Sayed Ali; Kargar-Dehnavi, Vida; Mousavi, Sayed Amir
2012-01-01
Background: Nickel-titanium (Ni-Ti) rotary instrument files are important devices in Endodontics in root canal preparation. Ni-Ti file breakage is a critical and problematic issue and irrigation techniques were applied to decrease risk of file failure root. The aim of the present study was to compare the temperature gradient change of different irrigation solutions with Ni-Ti rotary instrument system during root canal preparation and also to define their effects on the file failure. Materials and Methods: A novel computerized instrumentation was utilized and thirty standard (ProFile #25/.04) files were divided into three groups and subjected to a filing in the root canal test. Changes in temperature on teeth under constant instrumental conditions with custom-designed computerized experimental apparatus were measured by using a temperature sensor bonded to the apical hole. A rotary instrument for canal preparation in three series of solution was used and the changes in temperature after each solution were compared. Finally, the file failure results were mentored according to each step of test. Comparisons were performed between group status clinically by using ANOVA (t) test, once the sample showed up normal and differences of P<0.01 were considered significant. All data collected were computerized and analyzed for frequency, distribution, and statistical description. Results: There was a decrease in the temperature of the instruments, which were immersed in 5% NaOCl, when compared with the water group (P<0.01). There was also a decrease in the temperature of the instruments immersed in water, when compared with the no solution group (P<0.01). Test results showed that sodium hypochlorite, water, or air of root canals does alter the properties of gradual temperature change and contributes to the failure of the instruments. Conclusion: By immersing the file in 5% NaOCl, the temperature gradient decreased and instrument failure was reduced. PMID:23087732
Arya, Ashtha; Bali, Dildeep; Grewal, Mandeep S
2011-07-01
To compare the cleaning efficiency of manual and rotary instrumentation in the apical third of the root canal system. In group 1 (n=10), instrumentation was performed with stainless steel K-file; in group 2 (n=10), it was done with hand ProTaper files; and in group 3 (n=10), instrumentation was done with ProTaper rotary. Distilled water was used for irrigation. The apical third was sectioned transversally and histologically processed. The cross sections were examined under optic microscope and debris was measured using Motic software. Instrumentation with stainless steel K-files showed minimum amount of debris, followed by ProTaper hand files, and rotary ProTaper files were least effective with maximum amount of debris; however, there were no significant differences between the three experimental groups. Both the manual and rotary instrumentation are relatively efficient in cleaning the apical third of the root canal system and the choice between manual and rotary instrumentation should depend on case to case basis.
Pawar, Ajinkya M.; Pawar, Mansing G.; Metzger, Zvi; Kokate, Sharad R.
2015-01-01
Aim: The present ex vivo study aimed to evaluate the debris extrusion after instrumenting the root canals by three different files systems. Materials and Methods: Sixty extracted human mandibular premolars with single canals were selected and randomly divided into three groups (n = 20) for instrumentation with three different files. Group 1: WaveOne (primary) single reciprocating file (WO; Dentsply Maillefer, Ballaigues, Switzerland) (25/08), Group 2: Self-adjusting file (SAF; ReDent-Nova, Ra’anana, Israel) (1.5 mm), and Group 3: ProTaper NEXT X1 and X2 (PTN; Dentsply Tulsa Dental, Tulsa, OK) (25/06). Debris extruding by instrumentation were collected into pre-weighed Eppendorf tubes. These tubes were then stored in an incubator at 70°C for 5 days. The tubes were then weighed to obtain the final weight, with the extruded debris. Statistical analysis for the debris extruded apically was performed using one-way analysis of variance and post hoc Tukey's test. Results: The statistical analysis showed a significant difference between all the three groups tested (P < 0.01). The following post hoc Tukey's test confirmed that Group 2 (SAF) exhibited significantly least (P < 0.01) debris extrusion between the three groups tested. Conclusions: The SAF resulted in significantly less extrusion of debris when compared to reciprocating WO and rotary PTN. PMID:25829683
FERMI/GLAST Integrated Trending and Plotting System Release 5.0
NASA Technical Reports Server (NTRS)
Ritter, Sheila; Brumer, Haim; Reitan, Denise
2012-01-01
An Integrated Trending and Plotting System (ITPS) is a trending, analysis, and plotting system used by space missions to determine performance and status of spacecraft and its instruments. ITPS supports several NASA mission operational control centers providing engineers, ground controllers, and scientists with access to the entire spacecraft telemetry data archive for the life of the mission, and includes a secure Web component for remote access. FERMI/GLAST ITPS Release 5.0 features include the option to display dates (yyyy/ddd) instead of orbit numbers along orbital Long-Term Trend (LTT) plot axis, the ability to save statistics from daily production plots as image files, and removal of redundant edit/create Input Definition File (IDF) screens. Other features are a fix to address invalid packet lengths, a change in naming convention of image files in order to use in script, the ability to save all ITPS plot images (from Windows or the Web) as GIF or PNG format, the ability to specify ymin and ymax on plots where previously only the desired range could be specified, Web interface capability to plot IDFs that contain out-oforder page and plot numbers, and a fix to change all default file names to show yyyydddhhmmss time stamps instead of hhmmssdddyyyy. A Web interface capability sorts files based on modification date (with newest one at top), and the statistics block can be displayed via a Web interface. Via the Web, users can graphically view the volume of telemetry data from each day contained in the ITPS archive in the Web digest. The ITPS could be also used in nonspace fields that need to plot data or trend data, including financial and banking systems, aviation and transportation systems, healthcare and educational systems, sales and marketing, and housing and construction.
Bumm, Klaus; Zheng, Mingzhong; Bailey, Clyde; Zhan, Fenghuang; Chiriva-Internati, M; Eddlemon, Paul; Terry, Julian; Barlogie, Bart; Shaughnessy, John D
2002-02-01
Clinical GeneOrganizer (CGO) is a novel windows-based archiving, organization and data mining software for the integration of gene expression profiling in clinical medicine. The program implements various user-friendly tools and extracts data for further statistical analysis. This software was written for Affymetrix GeneChip *.txt files, but can also be used for any other microarray-derived data. The MS-SQL server version acts as a data mart and links microarray data with clinical parameters of any other existing database and therefore represents a valuable tool for combining gene expression analysis and clinical disease characteristics.
IRiS: construction of ARG networks at genomic scales.
Javed, Asif; Pybus, Marc; Melé, Marta; Utro, Filippo; Bertranpetit, Jaume; Calafell, Francesc; Parida, Laxmi
2011-09-01
Given a set of extant haplotypes IRiS first detects high confidence recombination events in their shared genealogy. Next using the local sequence topology defined by each detected event, it integrates these recombinations into an ancestral recombination graph. While the current system has been calibrated for human population data, it is easily extendible to other species as well. IRiS (Identification of Recombinations in Sequences) binary files are available for non-commercial use in both Linux and Microsoft Windows, 32 and 64 bit environments from https://researcher.ibm.com/researcher/view_project.php?id = 2303 parida@us.ibm.com.
Import Manipulate Plot RELAP5/MOD3 Data
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jones, K. R.
1999-10-05
XMGR5 was derived from an XY plotting tool called ACE/gr, which is copyrighted by Paul J. Turner and in the public domain. The interactive version of ACE/GR is xmgr, and includes a graphical interface to the X-windows system. Enhancements to xmgr have been developed which import, manipualate, and plot data from RELAP/MOD3, MELCOR, FRAPCON, and SINDA codes, and NRC databank files. capabilities, include two-phase property table lookup functions, an equation interpreter, arithmetic library functions, and units conversion. Plot titles, labels, legends, and narrative can be displayed using Latin or Cyrillic alphabets.
VizieR Online Data Catalog: Spectral line survey of two LOSs (Armijos-Abendano+, 2015)
NASA Astrophysics Data System (ADS)
Armijos-Abendano, J.; Martin-Pintado, J.; Requena-Torres, M. A.; Martin, S.; Rodriguez-Franco, A.
2017-11-01
The observations were carried out with the 22-m Mopra radio telescope in November 2007. We used the dual 3-mm Monolithic Microwave Integrated Circuit (MMIC) receiver connected to the 8-GHz spectrometer, which provided a velocity resolution of ~0.9 km/s at 90 GHz. Spectra in two polarizations were observed simultaneously. Two frequency ranges in the 3-mm window were covered, ~77-93 GHz and ~105-113 GHz. The beam size of the telescope was 38 arcsec at 90 GHz and 30 arcsec at 115 GHz. (3 data files).
Toolkit for testing scientific CCD cameras
NASA Astrophysics Data System (ADS)
Uzycki, Janusz; Mankiewicz, Lech; Molak, Marcin; Wrochna, Grzegorz
2006-03-01
The CCD Toolkit (1) is a software tool for testing CCD cameras which allows to measure important characteristics of a camera like readout noise, total gain, dark current, 'hot' pixels, useful area, etc. The application makes a statistical analysis of images saved in files with FITS format, commonly used in astronomy. A graphical interface is based on the ROOT package, which offers high functionality and flexibility. The program was developed in a way to ensure future compatibility with different operating systems: Windows and Linux. The CCD Toolkit was created for the "Pie of the Sky" project collaboration (2).
Selective Window Application of Gentamicin+ Dexamethasone in Meniere's Disease.
Ardıç, Fazıl Necdet; Tümkaya, Funda; Aykal, Kamil; Çabuk, Burçin
2017-08-01
The purpose of the study is to prevent hearing loss when using intratympanic (IT) gentamicin for intractable Meniere's disease. It is a retrospective case review study. Twenty five patients who had definite Meniere's disease and had either selective window application or weekly IT gentamicin were included into the study. First group (selective) had dexamethasone on the round window and gentamicin on oval window during exploratory tympanotomy procedure. The second group had IT gentamicin at weekly intervals. The degree of caloric weakness (CW), average hearing level in low pitch (HLP) (250, 500, 1000, 2000 Hz) and high pitch (HHP) (4000, 6000, 8000 Hz) were compared before and after treatment. The need for further treatment was noted. In the first group, the average HLP was increased from 51.6±7dB to 52.2±5.6 dB. The average HHP was increased 41.96±20.2 dB to 47.2±18.3 dB after treatment. The CW changed from 37.6±23.9 % to 54.6±30.6 %. In the second group, the average HLP was increased from 56.3±10.5 dB to 61.65±18.3 dB. The average HHP was increased 59.05±17.4 dB to 69.4±21.98 dB after treatment. The CW changed from 45.8±22.3% to 71.53±29.63 %. Both methods had statisticaly significant increase in caloric weakness. But only IT gentamicin led a significant hearing loss in HHP. The use of dexamethasone and gentamycin via different windows in the middle ear is safe and effective method for Meniere's disease in the short term. Application of dexamethasone protects not only the hearing cells but vestibular cells also.
Animal model of cochlear third window in the scala vestibuli or scala tympani.
Attias, Joseph; Preis, Michal; Shemesh, Rafi; Hadar, Tuvia; Nageris, Ben I
2010-08-01
The auditory impact of a cochlear third window differs by its location in the scala vestibuli or scala tympani. Pathologic third window has been investigated primarily in the vestibular apparatus of animals and humans. Dehiscence of the superior semicircular canal is the clinical model. Fat sand rats (n = 11) have a unique inner-ear anatomy that allows easy surgical access. A window was drilled in the bony labyrinth over the scala vestibuli in 1 group (12 ears) and over the scala tympani in another (7 ears) while preserving the membranous labyrinth. Auditory brain stem responses to high- and low-frequency stimuli delivered by air and bone conduction were recorded before and after the procedure. Scala vestibuli group: preoperative air-conduction thresholds to clicks and tone-bursts averaged 8.3 and 9.6 dB, respectively, and bone-conduction thresholds, 4.6 and 3.3 dB, respectively; after fenestration, air-conduction thresholds averaged 40.4 and 41.8 dB, respectively, and bone-conduction thresholds, -1 and 5.6 dB, respectively. Scala tympani group: preoperative air-conduction thresholds to clicks and tone-bursts averaged 8.6 dB each, and bone-conduction thresholds, 7.9 dB and 7.1 dB, respectively; after fenestration, air-conduction thresholds averaged 11.4 and 9.3 dB, respectively, and bone-conduction thresholds, 9.3 and 4.2 dB, respectively. The changes in air- (p = 0.0001) and bone-conduction (p = 0.04) thresholds were statistically significant only in the scala vestibuli group. The presence of a cochlear third window over the scala vestibuli, but not over the scala tympani, causes a significant increase in air-conduction auditory thresholds. These results agree with the theoretic model and clinical findings and contribute to our understanding of vestibular dehiscence.
Predictability effect on N400 reflects the severity of reading comprehension deficits in aphasia.
Chang, Chih-Ting; Lee, Chia-Ying; Chou, Chia-Ju; Fuh, Jong-Ling; Wu, Hsin-Chi
2016-01-29
Predictability effect on N400, in which low predictability words elicited a larger N400 than high predictability words did over central to posterior electrodes, has been used to index difficulty of lexical retrieval and semantic integration of words in sentence comprehension. This study examined predictability effect on N400 in aphasic patients to determine if the properties of N400 are suited to indexing the severity of reading comprehension deficits. Patients with aphasia were divided into high and low ability groups based on scores on the reading comprehension subtest in the Chinese Concise Aphasia Test (CCAT). The two aphasia groups, a group of healthy elders who were age-matched to the aphasic participants, and a group of young adults, were requested to read sentences that either ended with highly predictable words or unexpected but plausible words, while undergoing electroencephalography (EEG). The young adult and healthy elderly groups exhibited the typical centro-parietal distributed effect of predictability on N400; however, healthy elders exhibited a reduced N400 effect in a delayed time window compared to the young adults. Compared with the elderly control, the high ability aphasia group exhibited a comparable N400 effect in a more restricted time window; by contrast, the low ability aphasia group exhibited a frontal distributed N400 in a much later time window (400-700 ms). These data suggest that the severity of reading comprehension deficits affects predictability effect on a set of N400 characteristics (i.e., amplitude, time window, and topographic distribution), which may be effective as ERP signatures in the evaluation of language recovery in aphasia. Copyright © 2015 Elsevier Ltd. All rights reserved.
Kubios HRV--heart rate variability analysis software.
Tarvainen, Mika P; Niskanen, Juha-Pekka; Lipponen, Jukka A; Ranta-Aho, Perttu O; Karjalainen, Pasi A
2014-01-01
Kubios HRV is an advanced and easy to use software for heart rate variability (HRV) analysis. The software supports several input data formats for electrocardiogram (ECG) data and beat-to-beat RR interval data. It includes an adaptive QRS detection algorithm and tools for artifact correction, trend removal and analysis sample selection. The software computes all the commonly used time-domain and frequency-domain HRV parameters and several nonlinear parameters. There are several adjustable analysis settings through which the analysis methods can be optimized for different data. The ECG derived respiratory frequency is also computed, which is important for reliable interpretation of the analysis results. The analysis results can be saved as an ASCII text file (easy to import into MS Excel or SPSS), Matlab MAT-file, or as a PDF report. The software is easy to use through its compact graphical user interface. The software is available free of charge for Windows and Linux operating systems at http://kubios.uef.fi. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Magnetic Field Experiment Data Analysis System
NASA Technical Reports Server (NTRS)
Holland, D. B.; Zanetti, L. J.; Suther, L. L.; Potemra, T. A.; Anderson, B. J.
1995-01-01
The Johns Hopkins University Applied Physics Laboratory (JHU/APL) Magnetic Field Experiment Data Analysis System (MFEDAS) has been developed to process and analyze satellite magnetic field experiment data from the TRIAD, MAGSAT, AMPTE/CCE, Viking, Polar BEAR, DMSP, HILAT, UARS, and Freja satellites. The MFEDAS provides extensive data management and analysis capabilities. The system is based on standard data structures and a standard user interface. The MFEDAS has two major elements: (1) a set of satellite unique telemetry processing programs for uniform and rapid conversion of the raw data to a standard format and (2) the program Magplot which has file handling, data analysis, and data display sections. This system is an example of software reuse, allowing new data sets and software extensions to be added in a cost effective and timely manner. Future additions to the system will include the addition of standard format file import routines, modification of the display routines to use a commercial graphics package based on X-Window protocols, and a generic utility for telemetry data access and conversion.
CFS MATLAB toolbox: An experiment builder for continuous flash suppression (CFS) task.
Nuutinen, Mikko; Mustonen, Terhi; Häkkinen, Jukka
2017-09-15
CFS toolbox is an open-source collection of MATLAB functions that utilizes PsychToolbox-3 (PTB-3). It is designed to allow a researcher to create and run continuous flash suppression experiments using a variety of experimental parameters (i.e., stimulus types and locations, noise characteristics, and experiment window settings). In a CFS experiment, one of the eyes at a time is presented with a dynamically changing noise pattern, while the other eye is concurrently presented with a static target stimulus, such as a Gabor patch. Due to the strong interocular suppression created by the dominant noise pattern mask, the target stimulus is rendered invisible for an extended duration. Very little knowledge of MATLAB is required for using the toolbox; experiments are generated by modifying csv files with the required parameters, and result data are output to text files for further analysis. The open-source code is available on the project page under a Creative Commons License ( http://www.mikkonuutinen.arkku.net/CFS_toolbox/ and https://bitbucket.org/mikkonuutinen/cfs_toolbox ).
AirShow 1.0 CFD Software Users' Guide
NASA Technical Reports Server (NTRS)
Mohler, Stanley R., Jr.
2005-01-01
AirShow is visualization post-processing software for Computational Fluid Dynamics (CFD). Upon reading binary PLOT3D grid and solution files into AirShow, the engineer can quickly see how hundreds of complex 3-D structured blocks are arranged and numbered. Additionally, chosen grid planes can be displayed and colored according to various aerodynamic flow quantities such as Mach number and pressure. The user may interactively rotate and translate the graphical objects using the mouse. The software source code was written in cross-platform Java, C++, and OpenGL, and runs on Unix, Linux, and Windows. The graphical user interface (GUI) was written using Java Swing. Java also provides multiple synchronized threads. The Java Native Interface (JNI) provides a bridge between the Java code and the C++ code where the PLOT3D files are read, the OpenGL graphics are rendered, and numerical calculations are performed. AirShow is easy to learn and simple to use. The source code is available for free from the NASA Technology Transfer and Partnership Office.
Operation and control software for APNEA
DOE Office of Scientific and Technical Information (OSTI.GOV)
McClelland, J.H.; Storm, B.H. Jr.; Ahearn, J.
1997-11-01
The human interface software for the Lockheed Martin Specialty Components (LMSC) Active/Passive Neutron Examination & Analysis System (APENA) provides a user friendly operating environment for the movement and analysis of waste drums. It is written in Microsoft Visual C++ on a Windows NT platform. Object oriented and multitasking techniques are used extensively to maximize the capability of the system. A waste drum is placed on a loading platform with a fork lift and then automatically moved into the APNEA chamber in preparation for analysis. A series of measurements is performed, controlled by menu commands to hardware components attached as peripheralmore » devices, in order to create data files for analysis. The analysis routines use the files to identify the pertinent radioactive characteristics of the drum, including the type, location, and quantity of fissionable material. At the completion of the measurement process, the drum is automatically unloaded and the data are archived in preparation for storage as part of the drum`s data signature. 3 figs.« less
Al-Shahi, R; Sadler, M; Rees, G; Bateman, D
2002-01-01
The growing use of email and the world wide web (WWW), by the public, academics, and clinicians—as well as the increasing availability of high quality information on the WWW—make a working knowledge of the internet important. Although this article aims to enhance readers' existing use of the internet and medical resources on the WWW, it is also intelligible to someone unfamiliar with the internet. A web browser is one of the central pieces of software in modern computing: it is a window on the WWW, file transfer protocol sites, networked newsgroups, and your own computer's files. Effective use of the internet for professional purposes requires an understanding of the best strategies to search the WWW and the mechanisms for ensuring secure data transfer, as well as a compendium of online resources including journals, textbooks, medical portals, and sites providing high quality patient information. This article summarises these resources, available to incorporate into your web browser as downloadable "Favorites" or "Bookmarks" from www.jnnp.com, where there are also freely accessible hypertext links to the recommended sites. PMID:12438460
Chemopreventive Agent Development | Division of Cancer Prevention
[[{"fid":"174","view_mode":"default","fields":{"format":"default","field_file_image_alt_text[und][0][value]":"Chemoprevenentive Agent Development Research Group Homepage Logo","field_file_image_title_text[und][0][value]":"Chemoprevenentive Agent Development Research Group Homepage
NASA Astrophysics Data System (ADS)
Skurat, V. E.
2017-10-01
A series of experiments was carried out previously on board of the International Space Station in `EXPOSE-R', a multi-user expose facility, provided by European Space Agency attached to the external surface of the Russian Segment. In one experiment, spores of microorganisms and species of higher plant seeds, in heat-sealed polymer bags were irradiated by solar radiation passed through MgF2 windows in a high space vacuum. After sample exposure, it was found that in many cases the inner surfaces of windows were contaminated. Analysis of the contamination revealed the presence of chemical groups CH2, CH3, NH, OH, C═O, Si-CH3 (Demets et al. in 2015). Their presence in deposits was explained by photofixation of gaseous precursors - some of the vapours of glues and additives in polymeric materials in the core facility of `Expose-R'. Carbon-, oxygen- and silicon-containing groups may be deposited from outer intrinsic atmosphere. This atmosphere is connected with sample compartments and core facility. However, the presence of NH groups on inner surfaces of windows was not expected. This paper shows that the process responsible for carbon-, nitrogen- and oxygen-containing group formation can be a photopolymerization of caprolactam, which is released from the outer Nylon 6 layer of polymer bags under Solar vacuum ultraviolet radiation.
De-Deus, Gustavo; Brandão, Maria Claudia; Barino, Bianca; Di Giorgi, Karina; Fidel, Rivail Antonio Sergio; Luna, Aderval Severino
2010-09-01
This study was designed to quantitatively evaluate the amount of dentin debris extruded from the apical foramen by comparing the conventional sequence of the ProTaper Universal nickel-titanium (NiTi) files with the single-file ProTaper F2 technique. Thirty mesial roots of lower molars were selected, and the use of different instrumentation techniques resulted in 3 groups (n=10 each). In G1, a crown-down hand-file technique was used, and in G2 conventional ProTaper Universal technique was used. In G3, ProTaper F2 file was used in a reciprocating motion. The apical finish preparation was equivalent to ISO size 25. An apparatus was used to evaluate the apically extruded debris. Statistical analysis was performed using 1-way analysis of variance and Tukey multiple comparisons. No significant difference was found in the amount of the debris extruded between the conventional sequence of the ProTaper Universal NiTi files and the single-file ProTaper F2 technique (P>.05). In contrast, the hand instrumentation group extruded significantly more debris than both NiTi groups (P<.05). The present results yielded favorable input for the F2 single-file technique in terms of apically extruded debris, inasmuch as it is the most simple and cost-effective instrumentation approach. Copyright (c) 2010 Mosby, Inc. All rights reserved.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-23
... under 10 CFR 2.315(c), must be filed in accordance with the NRC E-Filing rule (72 FR 49139, August 28, 2007). The E-Filing process requires participants to submit and serve all adjudicatory documents over... below. To comply with the procedural requirements of E-Filing, at least 10 days prior to the filing...
PR-EDB: Power Reactor Embrittlement Database - Version 3
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Jy-An John; Subramani, Ranjit
2008-03-01
The aging and degradation of light-water reactor pressure vessels is of particular concern because of their relevance to plant integrity and the magnitude of the expected irradiation embrittlement. The radiation embrittlement of reactor pressure vessel materials depends on many factors, such as neutron fluence, flux, and energy spectrum, irradiation temperature, and preirradiation material history and chemical compositions. These factors must be considered to reliably predict pressure vessel embrittlement and to ensure the safe operation of the reactor. Large amounts of data from surveillance capsules are needed to develop a generally applicable damage prediction model that can be used for industrymore » standards and regulatory guides. Furthermore, the investigations of regulatory issues such as vessel integrity over plant life, vessel failure, and sufficiency of current codes, Standard Review Plans (SRPs), and Guides for license renewal can be greatly expedited by the use of a well-designed computerized database. The Power Reactor Embrittlement Database (PR-EDB) is such a comprehensive collection of data for U.S. designed commercial nuclear reactors. The current version of the PR-EDB lists the test results of 104 heat-affected-zone (HAZ) materials, 115 weld materials, and 141 base materials, including 103 plates, 35 forgings, and 3 correlation monitor materials that were irradiated in 321 capsules from 106 commercial power reactors. The data files are given in dBASE format and can be accessed with any personal computer using the Windows operating system. "User-friendly" utility programs have been written to investigate radiation embrittlement using this database. Utility programs allow the user to retrieve, select and manipulate specific data, display data to the screen or printer, and fit and plot Charpy impact data. The PR-EDB Version 3.0 upgrades Version 2.0. The package was developed based on the Microsoft .NET framework technology and uses Microsoft Access for backend data storage, and Microsoft Excel for plotting graphs. This software package is compatible with Windows (98 or higher) and has been built with a highly versatile user interface. PR-EDB Version 3.0 also contains an "Evaluated Residual File" utility for generating the evaluated processed files used for radiation embrittlement study.« less
A Tale of Two Observing Systems: Interoperability in the World of Microsoft Windows
NASA Astrophysics Data System (ADS)
Babin, B. L.; Hu, L.
2008-12-01
Louisiana Universities Marine Consortium's (LUMCON) and Dauphin Island Sea Lab's (DISL) Environmental Monitoring System provide a unified coastal ocean observing system. These two systems are mirrored to maintain autonomy while offering an integrated data sharing environment. Both systems collect data via Campbell Scientific Data loggers, store the data in Microsoft SQL servers, and disseminate the data in real- time on the World Wide Web via Microsoft Internet Information Servers and Active Server Pages (ASP). The utilization of Microsoft Windows technologies presented many challenges to these observing systems as open source tools for interoperability grow. The current open source tools often require the installation of additional software. In order to make data available through common standards formats, "home grown" software has been developed. One example of this is the development of software to generate xml files for transmission to the National Data Buoy Center (NDBC). OOSTethys partners develop, test and implement easy-to-use, open-source, OGC-compliant software., and have created a working prototype of networked, semantically interoperable, real-time data systems. Partnering with OOSTethys, we are developing a cookbook to implement OGC web services. The implementation will be written in ASP, will run in a Microsoft operating system environment, and will serve data via Sensor Observation Services (SOS). This cookbook will give observing systems running Microsoft Windows the tools to easily participate in the Open Geospatial Consortium (OGC) Oceans Interoperability Experiment (OCEANS IE).
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-22
... treatment and meaningful involvement of any group, including minority and/or low-income populations, in the... potential environmental justice issues, the Agency seeks information on any groups or segments of the..., cucurbit group 9 at 0.4 ppm; and vegetable, fruiting group 8-10 at 1.3 ppm. An enforcement method for plant...
Subramaniam, Priya; Tabrez, T A; Babu, K L Girish
2013-01-01
To assess the microflora of root canals in primary molars following use of rotary NiTi files and conventional hand NiTi and stainless steel files. This randomized clinical trial consisted of a total of 60 first and second primary molars requiring root canal treatment, who were selected from children aged 5-9 years. Based on type of root canal instrumentation, the teeth were randomly assigned to three groups of twenty teeth each; Group A: Rotary NiTi files, Group B: Hand NiTi files and Group C: Hand stainless steel files. Following administration of local anesthesia, isolation with rubber dam was carried out. For the purpose of instrumentation and sampling, the palatal canal of maxillary molars and the distal canal of mandibular molars were selected. Prior to sampling, the orifices of other canals in these teeth were sealed, so as to prevent any contamination. Instrumentation was carried out in each group using respective instruments along with intermittent saline irrigation. Root canal samples were obtained both before and after instrumentation, using sterile absorbent paper points and transferred to a sterile vial with transport fluid. Serial dilutions were prepared and cultured on suitable agar media. Both aerobic and anaerobic microbial counts were made. Data obtained was subjected to statistical analysis using Wilcoxon signed rank test and one-way Analysis of variance. In all three groups, there was a significant reduction in both aerobic and anaerobic mean microbial count following root canal instrumentation. (p < 0.001). Rotary NiTi files were as efficient as conventional hand instruments in significantly reducing the root canal microflora.
Yılmaz, Koray; Özyürek, Taha
2017-04-01
The aim of this study was to compare the amount of debris extruded from the apex during retreatment procedures with ProTaper Next (PTN; Dentsply Maillefer, Ballaigues, Switzerland), Reciproc (RCP; VDW, Munich, Germany), and Twisted File Adaptive (TFA; SybronEndo, Orange, CA) files and the duration of these retreatment procedures. Ninety upper central incisor teeth were prepared and filled with gutta-percha and AH Plus sealer (Dentsply DeTrey, Konstanz, Germany) using the vertical compaction technique. The teeth were randomly divided into 3 groups of 30 for removal of the root filling material with PTN, RCP, and TFA files. The apically extruded debris was collected in preweighed Eppendorf tubes. The time for gutta-percha removal was recorded. Data were statistically analyzed using Kruskal-Wallis and 1-way analysis of variance tests. The amount of debris extruded was RPC > TFA > PTN, respectively. Compared with the PTN group, the amount of debris extruded in the RPC group was statistically significantly higher (P < .001). There was no statistically significant difference among the RCP, TFA, and PTN groups regarding the time for retreatment (P > .05). Within the limitations of this in vitro study, all groups were associated with debris extrusion from the apex. The RCP file system led to higher levels of apical extrusion in proportion to the PTN file system. In addition, there was no significant difference among groups in the duration of the retreatment procedures. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
4 CFR 21.1 - Filing a protest.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 4 Accounts 1 2010-01-01 2010-01-01 false Filing a protest. 21.1 Section 21.1 Accounts GOVERNMENT ACCOUNTABILITY OFFICE GENERAL PROCEDURES BID PROTEST REGULATIONS § 21.1 Filing a protest. (a) An interested party... 20548, Attention: Procurement Law Control Group. (c) A protest filed with GAO shall: (1) Include the...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-19
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. ER11-4657-001] Apple Group LLC; Supplemental Notice That Initial Market-Based Rate Filing Includes Request for Blanket Section 204 Authorization This is a supplemental notice in the above-referenced proceeding of Apple Group LLC...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-06
... proceeding of Discount Energy Group, LLC's application for market-based rate authority, with an accompanying... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. ER10-2803-000] Discount Energy Group, LLC; Supplemental Notice That Initial Market-Based Rate Filing Includes Request for Blanket...
Community Oncology and Prevention Trials | Division of Cancer Prevention
[[{"fid":"168","view_mode":"default","fields":{"format":"default","field_file_image_alt_text[und][0][value]":"Early Detection Research Group Homepage Image","field_file_image_title_text[und][0][value]":"Early Detection Research Group Homepage Image","field_folder[und]":"15"},"type":"media","attributes":{"alt":"Early Detection Research Group Homepage Image","title":"Early
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-12
... SECURITIES AND EXCHANGE COMMISSION [File No. 500-1] Dialpoint Communications Corp., Pacel Corp., Quantum Group, Inc. (The), and Tradequest International, Inc.; Order of Suspension of Trading September 8... securities of Quantum Group, Inc. (The) because it has not filed any periodic reports since the period ended...
Prostate and Urologic Cancer | Division of Cancer Prevention
[[{"fid":"183","view_mode":"default","fields":{"format":"default","field_file_image_alt_text[und][0][value]":"Prostate and Urologic Cancer Research Group Homepage Logo","field_file_image_title_text[und][0][value]":"Prostate and Urologic Cancer Research Group Homepage
77 FR 12323 - Notice of Filing of Plats of Survey; Arizona
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-29
..., 2012, for Group 1089, Arizona. This plat was prepared at the request of the Bureau of Indian Affairs... February 16, 2012, and officially filed February 22, 2012, for Group 1089, Arizona. This plat was prepared...
LAS - LAND ANALYSIS SYSTEM, VERSION 5.0
NASA Technical Reports Server (NTRS)
Pease, P. B.
1994-01-01
The Land Analysis System (LAS) is an image analysis system designed to manipulate and analyze digital data in raster format and provide the user with a wide spectrum of functions and statistical tools for analysis. LAS offers these features under VMS with optional image display capabilities for IVAS and other display devices as well as the X-Windows environment. LAS provides a flexible framework for algorithm development as well as for the processing and analysis of image data. Users may choose between mouse-driven commands or the traditional command line input mode. LAS functions include supervised and unsupervised image classification, film product generation, geometric registration, image repair, radiometric correction and image statistical analysis. Data files accepted by LAS include formats such as Multi-Spectral Scanner (MSS), Thematic Mapper (TM) and Advanced Very High Resolution Radiometer (AVHRR). The enhanced geometric registration package now includes both image to image and map to map transformations. The over 200 LAS functions fall into image processing scenario categories which include: arithmetic and logical functions, data transformations, fourier transforms, geometric registration, hard copy output, image restoration, intensity transformation, multispectral and statistical analysis, file transfer, tape profiling and file management among others. Internal improvements to the LAS code have eliminated the VAX VMS dependencies and improved overall system performance. The maximum LAS image size has been increased to 20,000 lines by 20,000 samples with a maximum of 256 bands per image. The catalog management system used in earlier versions of LAS has been replaced by a more streamlined and maintenance-free method of file management. This system is not dependent on VAX/VMS and relies on file naming conventions alone to allow the use of identical LAS file names on different operating systems. While the LAS code has been improved, the original capabilities of the system have been preserved. These include maintaining associated image history, session logging, and batch, asynchronous and interactive mode of operation. The LAS application programs are integrated under version 4.1 of an interface called the Transportable Applications Executive (TAE). TAE 4.1 has four modes of user interaction: menu, direct command, tutor (or help), and dynamic tutor. In addition TAE 4.1 allows the operation of LAS functions using mouse-driven commands under the TAE-Facelift environment provided with TAE 4.1. These modes of operation allow users, from the beginner to the expert, to exercise specific application options. LAS is written in C-language and FORTRAN 77 for use with DEC VAX computers running VMS with approximately 16Mb of physical memory. This program runs under TAE 4.1. Since TAE 4.1 is not a current version of TAE, TAE 4.1 is included within the LAS distribution. Approximately 130,000 blocks (65Mb) of disk storage space are necessary to store the source code and files generated by the installation procedure for LAS and 44,000 blocks (22Mb) of disk storage space are necessary for TAE 4.1 installation. The only other dependencies for LAS are the subroutine libraries for the specific display device(s) that will be used with LAS/DMS (e.g. X-Windows and/or IVAS). The standard distribution medium for LAS is a set of two 9track 6250 BPI magnetic tapes in DEC VAX BACKUP format. It is also available on a set of two TK50 tape cartridges in DEC VAX BACKUP format. This program was developed in 1986 and last updated in 1992.
A comparison of apical transportation between FlexMaster and Twisted Files rotary instruments.
Duran-Sindreu, Fernando; García, Marc; Olivieri, Juan Gonzalo; Mercadé, Montse; Morelló, Sergio; Roig, Miguel
2012-07-01
The aim of this study was to evaluate apical transportation in root canals after the use of Twisted Files (TF; SybronEndo, Orange, CA) and FlexMaster (VDW, Munich, Germany) #40/04 rotary files. A double-digital radiographic technique was used to compare apical transportation between the TF and FlexMaster systems. Each rotary system was used to instrument mesial canals from 80 extracted mandibular molars. The central axes of the file imaged before instrumentation (#15 K-file) and the master apical rotary file (#40/04) were superimposed digitally. AutoCAD 2008 (Autodesk Inc, San Rafael, CA) was used to measure apical transportation at 0.5 mm from the working length (WL). The data were analyzed using the Student's t test, and significance was set at P < .05. The mean amount of apical transportation at 0.5 mm from the WL was 0.17 ± 0.09 mm for the FlexMaster group and 0.19 ± 0.12 mm for the TF group. No statistically significant differences in apical transportation were found between the 2 groups. Under the conditions of the study, no statistically significant differences in apical transportation were observed between FlexMaster and TF rotary files. Copyright © 2012 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Cai, J-J; Tang, X-N; Ge, J-Y
2017-07-01
To investigate the effect of irrigation on the surface roughness and fatigue resistance of HyFlex and M3 controlled memory (CM) wire nickel-titanium instruments. Two new files of each brand were analysed by atomic force microscopy (AFM). Then, the instruments were dynamically immersed in either 5.25% sodium hypochlorite (NaOCl) or 17% ethylene diamine tetraacetic acid (EDTA) solution for 10 min, followed by AFM analysis. The roughness average (Ra) and root mean square (RMS) values were analysed statistically using an independent sample t-test. Then, 36 files of each brand were randomly assigned to three groups (n = 12). Group 1 (the control group) was composed of new instruments. Groups 2 and 3 were dynamically immersed in 5.25% NaOCl and 17% EDTA solutions for 10 min, respectively. The number of rotations to failure for various groups was analysed using the one-way analysis of variance software. For M3 files, the Ra and RMS values significantly increased (P < 0.05) after the immersion. For the HyFlex file, the Ra and RMS values significantly increased (P < 0.05) only in EDTA, but not (P > 0.05) NaOCl. The resistance to cyclic fatigue of both HyFlex and M3 files did not significantly decrease (P > 0.05) by immersing in 5.25% NaOCl and 17% EDTA solutions. Except the HyFlex files immersed in NaOCl, the surface roughness of other files exposed to irrigants increased. However, a change in the surface tomography of CM wire instruments caused by contact with irrigants for 10 min did not trigger a decrease in cyclic fatigue resistance. © 2016 International Endodontic Journal. Published by John Wiley & Sons Ltd.
Defining window-boundaries for genomic analyses using smoothing spline techniques
Beissinger, Timothy M.; Rosa, Guilherme J.M.; Kaeppler, Shawn M.; ...
2015-04-17
High-density genomic data is often analyzed by combining information over windows of adjacent markers. Interpretation of data grouped in windows versus at individual locations may increase statistical power, simplify computation, reduce sampling noise, and reduce the total number of tests performed. However, use of adjacent marker information can result in over- or under-smoothing, undesirable window boundary specifications, or highly correlated test statistics. We introduce a method for defining windows based on statistically guided breakpoints in the data, as a foundation for the analysis of multiple adjacent data points. This method involves first fitting a cubic smoothing spline to the datamore » and then identifying the inflection points of the fitted spline, which serve as the boundaries of adjacent windows. This technique does not require prior knowledge of linkage disequilibrium, and therefore can be applied to data collected from individual or pooled sequencing experiments. Moreover, in contrast to existing methods, an arbitrary choice of window size is not necessary, since these are determined empirically and allowed to vary along the genome.« less
Design and Verification of Critical Pressurised Windows for Manned Spaceflight
NASA Astrophysics Data System (ADS)
Lamoure, Richard; Busto, Lara; Novo, Francisco; Sinnema, Gerben; Leal, Mendes M.
2014-06-01
The Window Design for Manned Spaceflight (WDMS) project was tasked with establishing the state-of-art and explore possible improvements to the current structural integrity verification and fracture control methodologies for manned spacecraft windows.A critical review of the state-of-art in spacecraft window design, materials and verification practice was conducted. Shortcomings of the methodology in terms of analysis, inspection and testing were identified. Schemes for improving verification practices and reducing conservatism whilst maintaining the required safety levels were then proposed.An experimental materials characterisation programme was defined and carried out with the support of the 'Glass and Façade Technology Research Group', at the University of Cambridge. Results of the sample testing campaign were analysed, post-processed and subsequently applied to the design of a breadboard window demonstrator.Two Fused Silica glass window panes were procured and subjected to dedicated analyses, inspection and testing comprising both qualification and acceptance programmes specifically tailored to the objectives of the activity.Finally, main outcomes have been compiled into a Structural Verification Guide for Pressurised Windows in manned spacecraft, incorporating best practices and lessons learned throughout this project.
This workgroup report addresses the central question: what are the critical windows during development (pre-conception through puberty) when exposure to xenobiotics may have the greatest adverse impact on subsequent reproductive health. The reproductive system develops in stages...
Schirrmeister, Jörg F; Strohl, Christian; Altenburger, Markus J; Wrbas, Karl-Thomas; Hellwig, Elmar
2006-06-01
To compare the shaping ability and safety of engine-driven FlexMaster, GT Rotary, ProFile, ProTaper, and RaCe rotary instrumentation and Hedström hand instrumentation in simulated root canals. One hundred fifty simulated colored root canals with a curvature of 20 degrees and a radius of 10 mm were randomly distributed among 6 groups of 25 specimens each. After preparation to apical size 30 the area of remaining color on the canal wall indicating unprepared areas was measured in mm2 using image analyzer software. Specimens treated with RaCe left least areas of remaining color compared to all other groups (P < .001), followed by ProTaper. Preparation with ProFile left behind the highest amount of unprepared areas. The ProFile group revealed significantly more remaining color than ProTaper, GT Rotary, and FlexMaster (P < .05). Four FlexMaster files separated. RaCe rotary files were safe and more effective compared to the other instruments.
NWChem: A comprehensive and scalable open-source solution for large scale molecular simulations
NASA Astrophysics Data System (ADS)
Valiev, M.; Bylaska, E. J.; Govind, N.; Kowalski, K.; Straatsma, T. P.; Van Dam, H. J. J.; Wang, D.; Nieplocha, J.; Apra, E.; Windus, T. L.; de Jong, W. A.
2010-09-01
The latest release of NWChem delivers an open-source computational chemistry package with extensive capabilities for large scale simulations of chemical and biological systems. Utilizing a common computational framework, diverse theoretical descriptions can be used to provide the best solution for a given scientific problem. Scalable parallel implementations and modular software design enable efficient utilization of current computational architectures. This paper provides an overview of NWChem focusing primarily on the core theoretical modules provided by the code and their parallel performance. Program summaryProgram title: NWChem Catalogue identifier: AEGI_v1_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/AEGI_v1_0.html Program obtainable from: CPC Program Library, Queen's University, Belfast, N. Ireland Licensing provisions: Open Source Educational Community License No. of lines in distributed program, including test data, etc.: 11 709 543 No. of bytes in distributed program, including test data, etc.: 680 696 106 Distribution format: tar.gz Programming language: Fortran 77, C Computer: all Linux based workstations and parallel supercomputers, Windows and Apple machines Operating system: Linux, OS X, Windows Has the code been vectorised or parallelized?: Code is parallelized Classification: 2.1, 2.2, 3, 7.3, 7.7, 16.1, 16.2, 16.3, 16.10, 16.13 Nature of problem: Large-scale atomistic simulations of chemical and biological systems require efficient and reliable methods for ground and excited solutions of many-electron Hamiltonian, analysis of the potential energy surface, and dynamics. Solution method: Ground and excited solutions of many-electron Hamiltonian are obtained utilizing density-functional theory, many-body perturbation approach, and coupled cluster expansion. These solutions or a combination thereof with classical descriptions are then used to analyze potential energy surface and perform dynamical simulations. Additional comments: Full documentation is provided in the distribution file. This includes an INSTALL file giving details of how to build the package. A set of test runs is provided in the examples directory. The distribution file for this program is over 90 Mbytes and therefore is not delivered directly when download or Email is requested. Instead a html file giving details of how the program can be obtained is sent. Running time: Running time depends on the size of the chemical system, complexity of the method, number of cpu's and the computational task. It ranges from several seconds for serial DFT energy calculations on a few atoms to several hours for parallel coupled cluster energy calculations on tens of atoms or ab-initio molecular dynamics simulation on hundreds of atoms.
[Mechanical properties of nickel-titanium files following multiple heat sterilizations].
Testarelli, L; Gallottini, L; Gambarini, G
2003-04-01
The effect of cycles of sterilization procedures on nickel-titanium (NiTi) endodontic instruments is a serious concern for practitioners. There is no agreement in the literature whether these procedures could adversely affect the mechanical properties of endodontic files, and, consequently, increase the risk of intracanal failure. The purpose of this study was to evaluate the mechanichal resistance of Hero (MicroMega, Besancon, France) instruments, before and after sterilization procedures. Thirty 02, 04, 06 tapered Hero size 30 new instruments were chosen and divided into 3 groups. Group A (control) were tested according to ANSI/ADA Spec.no 28 for torsional resistance, angle of torque and angle at breakage (45 inverted exclamation mark ). Group B files were first sterilized with chemiclave for 10 cycles of 20 minutes at 124 inverted exclamation mark C and then tested as described above. Group C files were first sterilized with glass beads for 10 cycles of 20 sec. at 250 inverted exclamation mark C and then tested as described above. Data were collected and statistically analyzed (t-paired test). Differences among the 3 groups were statistically not significant for both tests. All data were well within Spec.no 28 standard values. From the results of the present study, we may conclude that repeated sterilization procedures do not adversely affect the mechanichal resistance of Hero files.
OpenStereo: Open Source, Cross-Platform Software for Structural Geology Analysis
NASA Astrophysics Data System (ADS)
Grohmann, C. H.; Campanha, G. A.
2010-12-01
Free and open source software (FOSS) are increasingly seen as synonyms of innovation and progress. Freedom to run, copy, distribute, study, change and improve the software (through access to the source code) assure a high level of positive feedback between users and developers, which results in stable, secure and constantly updated systems. Several software packages for structural geology analysis are available to the user, with commercial licenses or that can be downloaded at no cost from the Internet. Some provide basic tools of stereographic projections such as plotting poles, great circles, density contouring, eigenvector analysis, data rotation etc, while others perform more specific tasks, such as paleostress or geotechnical/rock stability analysis. This variety also means a wide range of data formating for input, Graphical User Interface (GUI) design and graphic export format. The majority of packages is built for MS-Windows and even though there are packages for the UNIX-based MacOS, there aren't native packages for *nix (UNIX, Linux, BSD etc) Operating Systems (OS), forcing the users to run these programs with emulators or virtual machines. Those limitations lead us to develop OpenStereo, an open source, cross-platform software for stereographic projections and structural geology. The software is written in Python, a high-level, cross-platform programming language and the GUI is designed with wxPython, which provide a consistent look regardless the OS. Numeric operations (like matrix and linear algebra) are performed with the Numpy module and all graphic capabilities are provided by the Matplolib library, including on-screen plotting and graphic exporting to common desktop formats (emf, eps, ps, pdf, png, svg). Data input is done with simple ASCII text files, with values of dip direction and dip/plunge separated by spaces, tabs or commas. The user can open multiple file at the same time (or the same file more than once), and overlay different elements of each dataset (poles, great circles etc). The GUI shows the opened files in a tree structure, similar to “layers” of many illustration software, where the vertical order of the files in the tree reflects the drawing order of the selected elements. At this stage, the software performs plotting operations of poles to planes, lineations, great circles, density contours and rose diagrams. A set of statistics is calculated for each file and its eigenvalues and eigenvectors are used to suggest if the data is clustered about a mean value or distributed along a girdle. Modified Flinn, Triangular and histograms plots are also available. Next step of development will focus on tools as merging and rotation of datasets, possibility to save 'projects' and paleostress analysis. In its current state, OpenStereo requires Python, wxPython, Numpy and Matplotlib installed in the system. We recommend installing PythonXY or the Enthought Python Distribution on MS-Windows and MacOS machines, since all dependencies are provided. Most Linux distributions provide an easy way to install all dependencies through software repositories. OpenStereo is released under the GNU General Public License. Programmers willing to contribute are encouraged to contact the authors directly. FAPESP Grant #09/17675-5
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-16
... link to log on and submit the intervention or protests. Persons unable to file electronically should... protest should file with the Federal Energy Regulatory Commission, 888 First Street NE., Washington, DC... service, persons with Internet access who will eFile a document and/or be listed as a contact for an...
Beam shaping for laser initiated optical primers
NASA Astrophysics Data System (ADS)
Lizotte, Todd E.
2008-08-01
Remington was one of the first firearm manufacturing companies to file a patent for laser initiated firearms, in 1969. Nearly 40 years later, the development of laser initiated firearms has not become a mainstream technology in the civilian market. Requiring a battery is definitely a short coming, so it is easy to see how such a concept would be problematic. Having a firearm operate reliably and the delivery of laser energy in an efficient manner to ignite the shock-sensitive explosive primer mixtures is a tall task indeed. There has been considerable research on optical element based methods of transferring or compressing laser energy to ignite primer charges, including windows, laser chip primers and various lens shaped windows to focus the laser energy. The focusing of laser light needs to achieve igniting temperatures upwards of >400°C. Many of the patent filings covering this type of technology discuss simple approaches where a single point of light might be sufficient to perform this task. Alternatively a multi-point method might provide better performance, especially for mission critical applications, such as precision military firearms. This paper covers initial design and performance test of the laser beam shaping optics to create simultaneous multiple point ignition locations and a circumferential intense ring for igniting primer charge compounds. A simple initial test of the ring beam shaping technique was evaluated on a standard large caliber primer to determine its effectiveness on igniting the primer material. Several tests were conducted to gauge the feasibility of laser beam shaping, including optic fabrication and mounting on a cartridge, optic durability and functional ignition performance. Initial data will be presented, including testing of optically elements and empirical primer ignition / burn analysis.
SGRAPH (SeismoGRAPHer): Seismic waveform analysis and integrated tools in seismology
NASA Astrophysics Data System (ADS)
Abdelwahed, Mohamed F.
2012-03-01
Although numerous seismological programs are currently available, most of them suffer from the inability to manipulate different data formats and the lack of embedded seismological tools. SeismoGRAPHer, or simply SGRAPH, is a new system for maintaining and analyzing seismic waveform data in a stand-alone, Windows-based application that manipulates a wide range of data formats. SGRAPH was intended to be a tool sufficient for performing basic waveform analysis and solving advanced seismological problems. The graphical user interface (GUI) utilities and the Windows functionalities, such as dialog boxes, menus, and toolbars, simplify the user interaction with the data. SGRAPH supports common data formats, such as SAC, SEED, GSE, ASCII, and Nanometrics Y-format, and provides the ability to solve many seismological problems with built-in inversion tools. Loaded traces are maintained, processed, plotted, and saved as SAC, ASCII, or PS (post script) file formats. SGRAPH includes Generalized Ray Theory (GRT), genetic algorithm (GA), least-square fitting, auto-picking, fast Fourier transforms (FFT), and many additional tools. This program provides rapid estimation of earthquake source parameters, location, attenuation, and focal mechanisms. Advanced waveform modeling techniques are provided for crustal structure and focal mechanism estimation. SGRAPH has been employed in the Egyptian National Seismic Network (ENSN) as a tool assisting with routine work and data analysis. More than 30 users have been using previous versions of SGRAPH in their research for more than 3 years. The main features of this application are ease of use, speed, small disk space requirements, and the absence of third-party developed components. Because of its architectural structure, SGRAPH can be interfaced with newly developed methods or applications in seismology. A complete setup file, including the SGRAPH package with the online user guide, is available.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-06
... SECURITIES AND EXCHANGE COMMISSION [File No. 500-1] Dijji Corp., Hydro Environmental Resources, Inc. (n/k/a EXIM Internet Group, Inc.), Hydrogen Power, Inc., and InsynQ, Inc.; Order of Suspension of... Environmental Resources, Inc. (n/k/a EXIM Internet Group, Inc.) because it has not filed any periodic reports...
76 FR 38681 - Notice of Filing of Plats of Survey; Arizona
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-01
..., for Group 1080, Arizona. This plat was prepared at the request of the Bureau of Indian Affairs, Navajo..., accepted April 20, 2011, and officially filed April 21, 2011, for Group 1080, Arizona. This plat was... March 31, 2011, for Group 1080, Arizona. This plat was prepared at the request of the Bureau of Indian...
Social Influences on User Behavior in Group Information Repositories
ERIC Educational Resources Information Center
Rader, Emilee Jeanne
2009-01-01
Group information repositories are systems for organizing and sharing files kept in a central location that all group members can access. These systems are often assumed to be tools for storage and control of files and their metadata, not tools for communication. The purpose of this research is to better understand user behavior in group…
Influence of cervical preflaring on apical file size determination.
Pecora, J D; Capelli, A; Guerisoli, D M Z; Spanó, J C E; Estrela, C
2005-07-01
To investigate the influence of cervical preflaring with different instruments (Gates-Glidden drills, Quantec Flare series instruments and LA Axxess burs) on the first file that binds at working length (WL) in maxillary central incisors. Forty human maxillary central incisors with complete root formation were used. After standard access cavities, a size 06 K-file was inserted into each canal until the apical foramen was reached. The WL was set 1 mm short of the apical foramen. Group 1 received the initial apical instrument without previous preflaring of the cervical and middle thirds of the root canal. Group 2 had the cervical and middle portion of the root canals enlarged with Gates-Glidden drills sizes 90, 110 and 130. Group 3 had the cervical and middle thirds of the root canals enlarged with nickel-titanium Quantec Flare series instruments. Titanium-nitrite treated, stainless steel LA Axxess burs were used for preflaring the cervical and middle portions of root canals from group 4. Each canal was sized using manual K-files, starting with size 08 files with passive movements until the WL was reached. File sizes were increased until a binding sensation was felt at the WL, and the instrument size was recorded for each tooth. The apical region was then observed under a stereoscopic magnifier, images were recorded digitally and the differences between root canal and maximum file diameters were evaluated for each sample. Significant differences were found between experimental groups regarding anatomical diameter at the WL and the first file to bind in the canal (P < 0.01, 95% confidence interval). The major discrepancy was found when no preflaring was performed (0.151 mm average). The LA Axxess burs produced the smallest differences between anatomical diameter and first file to bind (0.016 mm average). Gates-Glidden drills and Flare instruments were ranked in an intermediary position, with no statistically significant differences between them (0.093 mm average). The instrument binding technique for determining anatomical diameter at WL is not precise. Preflaring of the cervical and middle thirds of the root canal improved anatomical diameter determination; the instrument used for preflaring played a major role in determining the anatomical diameter at the WL. Canals preflared with LA Axxess burs created a more accurate relationship between file size and anatomical diameter.
Imura, N; Kato, A S; Hata, G I; Uemura, M; Toda, T; Weine, F
2000-07-01
The purpose of this study was to quantify the amount of remaining gutta-percha/scaler on the walls of root canals when two engine-driven instruments (Quantec and ProFile) and two hand instruments (K-file and Hedström file) were used to remove these materials. The amount of apically extruded debris and the time required for treatment were also recorded. One hundred extracted mandibular premolars were prepared using a modified step-back, flare technique and obturated with the lateral condensation technique. After repreparation with the test instruments, the specimens were cut transversally at the cervical, middle and apical thirds with steel discs and the three sections were split longitudinally. The amount of residual debris on the canal walls in each section was examined using a stereomicroscope. In all groups the cervical and middle thirds showed no debris. In the apical third, obturating material was observed in some specimens. No statistically significant difference was found between the two groups for incidence of debris, although the Hedström group showed a greater number of samples with remaining gutta-percha/sealer. When analysing dirty specimens only, there was a statistically significant difference between the four groups (P < 0.01) with the Hedström group having significantly less length of canal wall with remaining obturation material than the Quantec group. There was no significant difference amongst the groups for weight of extruded debris. However, there was a significant difference amongst the groups for mean treatment time with the Hedström file group requiring significantly less time than the Quantec group (P < 0.001); no significant differences were found between the other groups. Six instruments fractured in the Quantec group, four in the ProFile group, two in the Hedström group and two in the K-type group. The results showed that overall, all instruments may leave filling material inside the root canal. During retreatment there is a risk of instrument breakage, especially rotary instruments.
Arcjet exploratory tests of ARC optical window design for the AFE vehicle
NASA Technical Reports Server (NTRS)
Whiting, Ellis E.; Terrazas-Salinas, Imelda; Craig, Roger A.; Sobeck, Charles K.; Sarver, George L., III; Salerno, Louis J.; Love, Wendell; Maa, Scott; Covington, AL
1991-01-01
Tests were made in the 20 MW arc jet facility at the NASA ARC to determine the suitability of sapphire and fused silica as window materials for the Aeroassist Flight Experiment (AFE) entry vehicle. Twenty nine tests were made; 25 at a heating rate about 80 percent of that expected during the AFE entry and 4 at approximately the full, 100 percent AFE heating rate profile, that produces a temperature of about 2900 F on the surface of the tiles that protect the vehicle. These tests show that a conductively cooled window design using mechanical thermal contacts and sapphire is probably not practical. Cooling the window using mechanical thermal contacts produces thermal stresses in the sapphire that cause the window to crack. An insulated design using sapphire, that cools the window as little as possible, appears promising although some spectral data in the vacuum-ultra-violet (VUV) will be lost due to the high temperature reached by the sapphire. The surface of the insulated sapphire windows, tested at the 100 percent AFE heating rate, showed some slight ablation, and cracks appeared in two of three test windows. One small group of cracks were obviously caused by mechanical binding of the window in the assembly, which can be eliminated with improved design. Other cracks were long, straight, thin crystallographic cracks that have very little effect on the optical transmission of the window. Also, the windows did not fall apart along these crystallographic cracks when the windows were removed from their assemblies. Theoretical results from the thermal analysis computer program SINDA indicate that increasing the window thickness from 4 to 8 mm may enable surface ablation to be avoided. An insulated design using a fused silica window tested at the nominal AFE heating rate experienced severe ablation, thus fused silica is not considered to be an acceptable window material.
Xu, Yi-Hua; Manoharan, Herbert T; Pitot, Henry C
2007-09-01
The bisulfite genomic sequencing technique is one of the most widely used techniques to study sequence-specific DNA methylation because of its unambiguous ability to reveal DNA methylation status to the order of a single nucleotide. One characteristic feature of the bisulfite genomic sequencing technique is that a number of sample sequence files will be produced from a single DNA sample. The PCR products of bisulfite-treated DNA samples cannot be sequenced directly because they are heterogeneous in nature; therefore they should be cloned into suitable plasmids and then sequenced. This procedure generates an enormous number of sample DNA sequence files as well as adding extra bases belonging to the plasmids to the sequence, which will cause problems in the final sequence comparison. Finding the methylation status for each CpG in each sample sequence is not an easy job. As a result CpG PatternFinder was developed for this purpose. The main functions of the CpG PatternFinder are: (i) to analyze the reference sequence to obtain CpG and non-CpG-C residue position information. (ii) To tailor sample sequence files (delete insertions and mark deletions from the sample sequence files) based on a configuration of ClustalW multiple alignment. (iii) To align sample sequence files with a reference file to obtain bisulfite conversion efficiency and CpG methylation status. And, (iv) to produce graphics, highlighted aligned sequence text and a summary report which can be easily exported to Microsoft Office suite. CpG PatternFinder is designed to operate cooperatively with BioEdit, a freeware on the internet. It can handle up to 100 files of sample DNA sequences simultaneously, and the total CpG pattern analysis process can be finished in minutes. CpG PatternFinder is an ideal software tool for DNA methylation studies to determine the differential methylation pattern in a large number of individuals in a population. Previously we developed the CpG Analyzer program; CpG PatternFinder is our further effort to create software tools for DNA methylation studies.
Reddy, Narender; Admala, Shilpa Reddy; Dinapadu, Sainath; Pasari, Srikanth; Reddy, Manoranjan P; Rao, M S Rama
2013-07-01
To evaluate the efficacy and cleaning ability of Hedstrom files, and ProTaper retreatment instruments in removing gutta-percha from root canals with and without xylene as solvent. Sixty extracted single rooted human teeth were selected and decoronated, straight access established working length determined 1 mm short of canal, chemomechanical preparation done and obturated with guttapercha and AH plus sealer. Samples were stored for 1 week in humidifier divided into four groups of 15 teeth each. • Group I: Hedstrom files without xylene. • Group II: Hedstrom files with xylene. • Group III: ProTaper retreatment instruments without xylene. • Group IV: ProTaper retreatment instruments with xylene. and the following criteria were assessed - Time taken for initial plunge of instrument into guttapercha. - Time taken for complete removal of gutta-percha to reach working length - Ability of H files and ProTaper retreatment files with/ without xylene to remove gutta-percha in coronal, middle and apical 1/3 of canal. The teeth were grooved in labiolingual cross section, observed under a steromicroscope and scored according to gutta-percha debris left in the canal. Results were evaluated using ANOVA test and multiple comparisons done using Scheffe test. The least time to reach working length was found with group IV followed by groups III, II and group I respectively. Also the fastest way to remove maximum gutta-percha was group IV followed by groups III, II, and I respectively with a statistically significant difference among all groups. Apical 1/3 has more amount of remaining gutta-percha debris than middle and coronal 1/3 in all groups. The amount of gutta-percha debris in apical 1/3 was least in group IV followed by groups III, II and I respectively. The better performance of ProTaper rotary instruments has been attributed to their special flute design which tends to pull gutta-percha coronally directing it toward orifice. Also the movements of engine driven instruments produce frictional heat which plasticises gutta-percha and aids in easy removal. Apical third of root canals showed more guttapercha debris compared to coronal and middle 1/3 and has been attributed to the greater anatomic variability and difficulty of instrumentation in the apical area. The existence of deep groves and depressions on dentine walls in this apical 1/3 make them less instrumented areas as it did be difficult to direct the file against the extreme root canal wall. The fastest technique to remove gutta-percha and the shortest time to reach working length was observed with ProTaper retreatment instruments with xylene followed by ProTaper retreatment files without xylene and Hedstrom files without xylene. After instrumentation for removal of gutta-percha, apical third was found to have more debris compared to coronal and middle 1/3 of the root canal.
Kerzel, Dirk; Born, Sabine; Schönhammer, Josef
2012-12-01
A salient stimulus may interrupt visual search because of attentional capture. It has been shown that attentional capture occurs with a wide, but not with a small attentional window. We tested the hypothesis that capture depends more strongly on the shape of the attentional window than on its size. Search elements were arranged in two nested rings. The ring containing the search target remained fixed, while a salient color singleton occurred either in the same or in the other ring. We observed that color singletons only disrupted search when shown in the same ring as the search target. It is important to note that, when focusing on the outer array, which presumably required a larger attentional window, singletons on the inner array did not capture attention. In contrast to the original attentional window hypothesis, our results show that attentional capture does not always occur with a large attentional window. Rather, attention can be flexibly allocated to the set of relevant stimulus locations and attentional capture is confined to the attended locations. Further experiments showed that attention was allocated to search elements that were perceptually grouped into "whole" or "Gestalt"-like objects, which prevented attentional capture from nearby locations. However, when attention was allocated to noncontiguous locations that did not form a perceptual Gestalt, nearby locations elicited attentional capture. Perceptual grouping could be based on a combination of color and position, but not on color alone. Thus, the allocation of attention to Gestalt-like objects that were jointly defined by similarity and proximity prevented attentional capture from nearby locations.
Sekar, Vadhana; Kumar, Ranjith; Nandini, Suresh; Ballal, Suma; Velmurugan, Natanasabapathy
2016-01-01
The purpose of this study was to assess the role of cross section on cyclic fatigue resistance of One Shape, Revo-S SU, and Mtwo rotary files in continuous rotation and reciprocating motion in dynamic testing model. A total of 90 new rotary One Shape, Revo-S SU, and Mtwo files (ISO size 25, taper 0.06, length 25 mm) were subjected to continuous rotation or reciprocating motion. A cyclic fatigue testing device was fabricated with 60° angle of curvature and 5 mm radius. The dynamic testing of these files was performed using an electric motor which permitted the reproduction of pecking motion. All instruments were rotated or reciprocated until fracture occurred. The time taken for each instrument to fracture was recorded. All the fractured files were analyzed under a scanning electron microscope (SEM) to detect the mode of fracture. Statistical analysis was performed using one-way ANOVA, followed by Tukey's honestly significant difference post hoc test. The time taken for instruments in reciprocating motion to fail under cyclic loading was significantly longer when compared with groups in continuous rotary motion. There was a statistically significant difference between Mtwo rotary and the other two groups in both continuous and reciprocating motion. One Shape rotary files recorded significantly longer duration to fracture resistance when compared with Revo-S SU files in both continuous and reciprocating motion. SEM observations showed that the instruments of all groups had undergone a ductile mode of fracture. Reciprocating motion improved the cyclic fatigue resistance of all tested groups.
Sekar, Vadhana; Kumar, Ranjith; Nandini, Suresh; Ballal, Suma; Velmurugan, Natanasabapathy
2016-01-01
Objective: The purpose of this study was to assess the role of cross section on cyclic fatigue resistance of One Shape, Revo-S SU, and Mtwo rotary files in continuous rotation and reciprocating motion in dynamic testing model. Materials and Methods: A total of 90 new rotary One Shape, Revo-S SU, and Mtwo files (ISO size 25, taper 0.06, length 25 mm) were subjected to continuous rotation or reciprocating motion. A cyclic fatigue testing device was fabricated with 60° angle of curvature and 5 mm radius. The dynamic testing of these files was performed using an electric motor which permitted the reproduction of pecking motion. All instruments were rotated or reciprocated until fracture occurred. The time taken for each instrument to fracture was recorded. All the fractured files were analyzed under a scanning electron microscope (SEM) to detect the mode of fracture. Statistical analysis was performed using one-way ANOVA, followed by Tukey's honestly significant difference post hoc test. Results: The time taken for instruments in reciprocating motion to fail under cyclic loading was significantly longer when compared with groups in continuous rotary motion. There was a statistically significant difference between Mtwo rotary and the other two groups in both continuous and reciprocating motion. One Shape rotary files recorded significantly longer duration to fracture resistance when compared with Revo-S SU files in both continuous and reciprocating motion. SEM observations showed that the instruments of all groups had undergone a ductile mode of fracture. Conclusion: Reciprocating motion improved the cyclic fatigue resistance of all tested groups. PMID:28042272
Özyürek, Taha; Tek, Vildan; Yılmaz, Koray; Uslu, Gülşah
2017-11-01
To determine the incidence of crack formation and propagation in apical root dentin after retreatment procedures performed using ProTaper Universal Retreatment (PTR), Mtwo-R, ProTaper Next (PTN), and Twisted File Adaptive (TFA) systems. The study consisted of 120 extracted mandibular premolars. One millimeter from the apex of each tooth was ground perpendicular to the long axis of the tooth, and the apical surface was polished. Twenty teeth served as the negative control group. One hundred teeth were prepared, obturated, and then divided into 5 retreatment groups. The retreatment procedures were performed using the following files: PTR, Mtwo-R, PTN, TFA, and hand files. After filling material removal, apical enlargement was done using apical size 0.50 mm ProTaper Universal (PTU), Mtwo, PTN, TFA, and hand files. Digital images of the apical root surfaces were recorded before preparation, after preparation, after obturation, after filling removal, and after apical enlargement using a stereomicroscope. The images were then inspected for the presence of new apical cracks and crack propagation. Data were analyzed with χ 2 tests using SPSS 21.0 software. New cracks and crack propagation occurred in all the experimental groups during the retreatment process. Nickel-titanium rotary file systems caused significantly more apical crack formation and propagation than the hand files. The PTU system caused significantly more apical cracks than the other groups after the apical enlargement stage. This study showed that retreatment procedures and apical enlargement after the use of retreatment files can cause crack formation and propagation in apical dentin.
Implementation of EPICS based vacuum control system for variable energy cyclotron centre, Kolkata
NASA Astrophysics Data System (ADS)
Roy, Anindya; Bhole, R. B.; Nandy, Partha P.; Yadav, R. C.; Pal, Sarbajit; Roy, Amitava
2015-03-01
The vacuum system of the Room Temperature (K = 130) Cyclotron of Variable Energy Cyclotron Centre is comprised of vacuum systems of main machine and Beam Transport System. The vacuum control system is upgraded to a PLC based Automated system from the initial relay based Manual system. The supervisory control of the vacuum system is implemented in Experimental Physics and Industrial Control System (EPICS). An EPICS embedded ARM based vacuum gauge controller is developed to mitigate the requirement of vendor specific gauge controller for gauges and also for seamless integration of the gauge controllers with the control system. A set of MS-Windows ActiveX components with embedded EPICS Channel Access interface are developed to build operator interfaces with less complex programming and to incorporate typical Windows feature, e.g., user authentication, file handling, better fonts, colors, mouse actions etc. into the operator interfaces. The control parameters, monitoring parameters, and system interlocks of the system are archived in MySQL based EPICS MySQL Archiver developed indigenously. In this paper, we describe the architecture, the implementation details, and the performance of the system.
Simple proteomics data analysis in the object-oriented PowerShell.
Mohammed, Yassene; Palmblad, Magnus
2013-01-01
Scripting languages such as Perl and Python are appreciated for solving simple, everyday tasks in bioinformatics. A more recent, object-oriented command shell and scripting language, Windows PowerShell, has many attractive features: an object-oriented interactive command line, fluent navigation and manipulation of XML files, ability to consume Web services from the command line, consistent syntax and grammar, rich regular expressions, and advanced output formatting. The key difference between classical command shells and scripting languages, such as bash, and object-oriented ones, such as PowerShell, is that in the latter the result of a command is a structured object with inherited properties and methods rather than a simple stream of characters. Conveniently, PowerShell is included in all new releases of Microsoft Windows and therefore already installed on most computers in classrooms and teaching labs. In this chapter we demonstrate how PowerShell in particular allows easy interaction with mass spectrometry data in XML formats, connection to Web services for tools such as BLAST, and presentation of results as formatted text or graphics. These features make PowerShell much more than "yet another scripting language."
Software for Viewing Landsat Mosaic Images
NASA Technical Reports Server (NTRS)
Watts, Zack; Farve, Catharine L.; Harvey, Craig
2003-01-01
A Windows-based computer program has been written to enable novice users (especially educators and students) to view images of large areas of the Earth (e.g., the continental United States) generated from image data acquired in the Landsat observations performed circa the year 1990. The large-area images are constructed as mosaics from the original Landsat images, which were acquired in several wavelength bands and each of which spans an area (in effect, one tile of a mosaic) of .5 in latitude by .6 in longitude. Whereas the original Landsat data are registered on a universal transverse Mercator (UTM) grid, the program converts the UTM coordinates of a mouse pointer in the image to latitude and longitude, which are continuously updated and displayed as the pointer is moved. The mosaic image currently on display can be exported as a Windows bitmap file. Other images (e.g., of state boundaries or interstate highways) can be overlaid on Landsat mosaics. The program interacts with the user via standard toolbar, keyboard, and mouse user interfaces. The program is supplied on a compact disk along with tutorial and educational information.
Program Predicts Performance of Optical Parametric Oscillators
NASA Technical Reports Server (NTRS)
Cross, Patricia L.; Bowers, Mark
2006-01-01
A computer program predicts the performances of solid-state lasers that operate at wavelengths from ultraviolet through mid-infrared and that comprise various combinations of stable and unstable resonators, optical parametric oscillators (OPOs), and sum-frequency generators (SFGs), including second-harmonic generators (SHGs). The input to the program describes the signal, idler, and pump beams; the SFG and OPO crystals; and the laser geometry. The program calculates the electric fields of the idler, pump, and output beams at three locations (inside the laser resonator, just outside the input mirror, and just outside the output mirror) as functions of time for the duration of the pump beam. For each beam, the electric field is used to calculate the fluence at the output mirror, plus summary parameters that include the centroid location, the radius of curvature of the wavefront leaving through the output mirror, the location and size of the beam waist, and a quantity known, variously, as a propagation constant or beam-quality factor. The program provides a typical Windows interface for entering data and selecting files. The program can include as many as six plot windows, each containing four graphs.
Implementation of EPICS based vacuum control system for variable energy cyclotron centre, Kolkata.
Roy, Anindya; Bhole, R B; Nandy, Partha P; Yadav, R C; Pal, Sarbajit; Roy, Amitava
2015-03-01
The vacuum system of the Room Temperature (K = 130) Cyclotron of Variable Energy Cyclotron Centre is comprised of vacuum systems of main machine and Beam Transport System. The vacuum control system is upgraded to a PLC based Automated system from the initial relay based Manual system. The supervisory control of the vacuum system is implemented in Experimental Physics and Industrial Control System (EPICS). An EPICS embedded ARM based vacuum gauge controller is developed to mitigate the requirement of vendor specific gauge controller for gauges and also for seamless integration of the gauge controllers with the control system. A set of MS-Windows ActiveX components with embedded EPICS Channel Access interface are developed to build operator interfaces with less complex programming and to incorporate typical Windows feature, e.g., user authentication, file handling, better fonts, colors, mouse actions etc. into the operator interfaces. The control parameters, monitoring parameters, and system interlocks of the system are archived in MySQL based EPICS MySQL Archiver developed indigenously. In this paper, we describe the architecture, the implementation details, and the performance of the system.
Preliminary Geologic Map of the Topanga 7.5' Quadrangle, Southern California: A Digital Database
Yerkes, R.F.; Campbell, R.H.
1995-01-01
INTRODUCTION This Open-File report is a digital geologic map database. This pamphlet serves to introduce and describe the digital data. There is no paper map included in the Open-File report. This digital map database is compiled from previously published sources combined with some new mapping and modifications in nomenclature. The geologic map database delineates map units that are identified by general age and lithology following the stratigraphic nomenclature of the U. S. Geological Survey. For detailed descriptions of the units, their stratigraphic relations and sources of geologic mapping consult Yerkes and Campbell (1994). More specific information about the units may be available in the original sources. The content and character of the database and methods of obtaining it are described herein. The geologic map database itself, consisting of three ARC coverages and one base layer, can be obtained over the Internet or by magnetic tape copy as described below. The processes of extracting the geologic map database from the tar file, and importing the ARC export coverages (procedure described herein), will result in the creation of an ARC workspace (directory) called 'topnga.' The database was compiled using ARC/INFO version 7.0.3, a commercial Geographic Information System (Environmental Systems Research Institute, Redlands, California), with version 3.0 of the menu interface ALACARTE (Fitzgibbon and Wentworth, 1991, Fitzgibbon, 1991, Wentworth and Fitzgibbon, 1991). It is stored in uncompressed ARC export format (ARC/INFO version 7.x) in a compressed UNIX tar (tape archive) file. The tar file was compressed with gzip, and may be uncompressed with gzip, which is available free of charge via the Internet from the gzip Home Page (http://w3.teaser.fr/~jlgailly/gzip). A tar utility is required to extract the database from the tar file. This utility is included in most UNIX systems, and can be obtained free of charge via the Internet from Internet Literacy's Common Internet File Formats Webpage http://www.matisse.net/files/formats.html). ARC/INFO export files (files with the .e00 extension) can be converted into ARC/INFO coverages in ARC/INFO (see below) and can be read by some other Geographic Information Systems, such as MapInfo via ArcLink and ESRI's ArcView (version 1.0 for Windows 3.1 to 3.11 is available for free from ESRI's web site: http://www.esri.com). 1. Different base layer - The original digital database included separates clipped out of the Los Angeles 1:100,000 sheet. This release includes a vectorized scan of a scale-stable negative of the Topanga 7.5 minute quadrangle. 2. Map projection - The files in the original release were in polyconic projection. The projection used in this release is state plane, which allows for the tiling of adjacent quadrangles. 3. File compression - The files in the original release were compressed with UNIX compression. The files in this release are compressed with gzip.
American Telephone and Telegraph System V/MLS Release 1.1.2 Running on Unix System V Release 3.1.1
1989-10-18
Evaluation Report AT&T System V/MLS SYSTEM OVERVIEW what is specified in the /mls/ passwd file. For a complete description of how this works, see page 62...from the publicly readable files /etc/ passwd and /etclgroup, to the protected files /mlslpasswd and /mls/group. These protected files are ASCII...files which are referred to as "shadow files". October 18, 1989 62 Final Evaluation Report AT&T System V/MLS SYSTEM OVERVIEW Imls/ passwd contains the
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-10
... PHM Pulte Group Inc. Banking ETF. 300 XL XL Group Plc 350 HOT Starwood Hotels & Resorts Worldwide Inc... . Please include File Number SR-NYSEAmex-2010-73 on the subject line. Paper Comments Send paper comments in...
29 CFR 2560.502c-5 - Civil penalties under section 502(c)(5).
Code of Federal Regulations, 2011 CFR
2011-07-01
... Act) that is not a group health plan, and that provides benefits consisting of medical care (within... section 502(c)(5) of the Act for each failure or refusal to file a completed report required to be filed...). (2) For purposes of this section, a failure or refusal to file the report required to be filed under...
29 CFR 2560.502c-5 - Civil penalties under section 502(c)(5).
Code of Federal Regulations, 2010 CFR
2010-07-01
... Act) that is not a group health plan, and that provides benefits consisting of medical care (within... section 502(c)(5) of the Act for each failure or refusal to file a completed report required to be filed...). (2) For purposes of this section, a failure or refusal to file the report required to be filed under...
Topçuoğlu, Gamze; Topçuoğlu, Hüseyin Sinan; Akpek, Firdevs
2016-09-01
To assess the amount of debris extruded apically during root canal preparation using various nickel titanium instrumentation systems and hand files in primary molar teeth. Sixty extracted primary first mandibular molar human teeth were randomly assigned to four groups (n = 15 teeth for each group). The canals were then instrumented with the following instrument systems: Revo-S, Mtwo, ProTaper Next, and hand files. Apically extruded debris during instrumentation was collected into pre-weighed Eppendorf tubes. The Eppendorf tubes were then stored in an incubator at 70°C for 5 days. The weight of the dry extruded debris was established by subtracting the pre-instrumentation and post-instrumentation weight of the Eppendorf tubes for each group. The data were analyzed using one-way analysis of variance (anova) and Tukey's post hoc tests. ProTaper Next files were associated with less apically extruded debris than the Mtwo, Revo-S, and hand files (P < 0.05). Hand files extruded more debris than Mtwo and Revo-S instruments (P < 0.05), but there was no significant difference found between the Mtwo and Revo-S instruments (P > 0.05). All instruments were associated with apical extrusion of debris. ProTaper Next files caused less debris extrusion compared to the other systems used. © 2015 BSPD, IAPD and John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Özyürek, T; Uslu, G; Gündoğar, M; Yılmaz, K; Grande, N M; Plotino, G
2018-02-25
To compare the cyclic fatigue resistance and bending properties of R-Pilot and WaveOne Gold (WOG) Glider files, at intracanal temperature (35°C). Forty R-Pilot and 40 WOG Glider files were subjected to a cyclic fatigue resistance test (n = 20), calculating the time to fracture (TTF) in an artificial stainless steel canal. The length of the fractured file tips (FL) was also measured. The fracture surface of fragments was examined with a scanning electron microscope, and the cross-sectional area of the fractured surfaces was measured. Flexibility of the tested files (n = 20) was determined using 45° bending test. Data were analysed statistically using the Mann-Whitney U-test at 5% significance level. Time to fracture was significantly higher in the R-Pilot group compared to the WOG Glider (P < 0.05). There was no significant difference between groups for fracture length. The bending resistance of R-Pilot files was significantly greater than WOG Glider files (P < 0.05). A significant greater cyclic fatigue resistance was observed for R-Pilot files compared to WOG Glider instruments, although the bending resistance of WOG Glider files was lower. © 2018 International Endodontic Journal. Published by John Wiley & Sons Ltd.
Bürklein, S; Benten, S; Schäfer, E
2014-05-01
To assess in a laboratory setting the amount of apically extruded debris associated with different single-file nickel-titanium instrumentation systems compared to one multiple-file rotary system. Eighty human mandibular central incisors were randomly assigned to four groups (n = 20 teeth per group). The root canals were instrumented according to the manufacturers' instructions using the reciprocating single-file system Reciproc, the single-file rotary systems F360 and OneShape and the multiple-file rotary Mtwo instruments. The apically extruded debris was collected and dried in pre-weighed glass vials. The amount of debris was assessed with a micro balance and statistically analysed using anova and post hoc Student-Newman-Keuls test. The time required to prepare the canals with the different instruments was also recorded. Reciproc produced significantly more debris compared to all other systems (P < 0.05). No significant difference was noted between the two single-file rotary systems and the multiple-file rotary system (P > 0.05). Instrumentation with the three single-file systems was significantly faster than with Mtwo (P < 0.05). Under the condition of this study, all systems caused apical debris extrusion. Rotary instrumentation was associated with less debris extrusion compared to reciprocal instrumentation. © 2013 International Endodontic Journal. Published by John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Sordillo, Laura A.; Pu, Yang; Sordillo, P. P.; Budansky, Yury; Alfano, Robert R.
2014-03-01
Near-infrared (NIR) light in the wavelengths of 700 nm to 2,000 nm has three NIR optical, or therapeutic, windows, which allow for deeper depth penetration in scattering tissue media. Microfractures secondary to repetitive stress, particularly in the lower extremities, are an important problem for military recruits and athletes. They also frequently occur in the elderly, or in patients taking bisphosphonates or denosumab. Microfractures can be early predictors of a major bone fracture. Using the second and third NIR therapeutic windows, we investigated the results from images of chicken bone and human tibial bone with microfractures and non-displaced fractures with and without overlying tissues of various thicknesses. Images of bone with microfractures and non-displaced fractures with tissue show scattering photons in the third NIR window with wavelengths between 1,650 nm and 1,870 nm are diminished and absorption is increased slightly from and second NIR windows. Results from images of fractured bones show the attenuation length of light through tissue in the third optical window to be larger than in the second therapeutic window. Use of these windows may aid in the detection of bone microfractures, and thus reduce the incidence of major bone fracture in susceptible groups.
Spradley, James W; Eleazer, Paul D
2010-01-01
Three-dimensional cleaning of the root canal system along its basic shape is one of the main goals in endodontics. A sonic handpiece is a helpful adjunct that can aid in accomplishing this goal; however, its use has been limited due to the risk of transporting the apices' original position. Precurving sonic files may reduce transportation. For this study, 35 plastic blocks were randomly assigned to two groups, one of which (n = 16) was instrumented by nickel-titanium rotary files (to a size 40), while the second group (n = 18) was instrumented by a sonic handpiece with precurved files. Similar blocks were instrumented with noncurved sonic files and used as controls. Radiographs taken before and after instrumentation were compared. Of the 18 apices instrumented by the sonic handpiece with precurved files, seven were not transported. By comparison, 8 of the 16 apices instrumented by nickel-titanium files did not transport. When transportation did occur, it was less than 0.5 mm for either technique. The control blocks instrumented by the sonic handpiece with straight files were transported significantly. An ANOVA with a post hoc Tukey's test showed no statistically significant difference between the file systems. Based on the results, precurving sonic files to match the canal contour may allow for efficient cleaning without undue transportation.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-21
... SECURITIES AND EXCHANGE COMMISSION In the Matter of Cape Systems Group, Inc., Caribbean Cigar...., File No. 500-1; Order of Suspension of Trading October 19, 2010. It appears to the Securities and... Cape Systems Group, Inc. because it has not filed any periodic reports since the period ended December...
Johnson, M A; Primack, P D; Loushine, R J; Craft, D W
1997-01-01
Ninety-two new endodontic files were randomly assigned to five groups with varying parameters of contamination, cleaning method, and sterilization (steam or chemical). Files were instrumented in bovine teeth to accumulate debris and a known contaminant, Bacillus stearothermophilus. Positive controls produced growth on both T-soy agar plates and in T-soy broth. Negative controls and experimental files (some with heavy debris) failed to produce growth. The results showed that there was no significant difference between contaminated files that were not cleaned before sterilization and contaminated files that were cleaned before sterilization. Bioburden present on endodontic files does not appear to affect the sterilization process.
47 CFR 90.165 - Procedures for mutually exclusive applications.
Code of Federal Regulations, 2014 CFR
2014-10-01
..., the Commission may use competitive bidding, random selection, or comparative hearings, depending on... exclusive applications in a renewal filing group are designated for comparative consideration in a hearing... applications in the filing group for comparative consideration in a hearing. In this event, the result of the...
47 CFR 90.165 - Procedures for mutually exclusive applications.
Code of Federal Regulations, 2012 CFR
2012-10-01
..., the Commission may use competitive bidding, random selection, or comparative hearings, depending on... exclusive applications in a renewal filing group are designated for comparative consideration in a hearing... applications in the filing group for comparative consideration in a hearing. In this event, the result of the...
47 CFR 90.165 - Procedures for mutually exclusive applications.
Code of Federal Regulations, 2013 CFR
2013-10-01
..., the Commission may use competitive bidding, random selection, or comparative hearings, depending on... exclusive applications in a renewal filing group are designated for comparative consideration in a hearing... applications in the filing group for comparative consideration in a hearing. In this event, the result of the...
Grouping by proximity and the visual impression of approximate number in random dot arrays.
Im, Hee Yeon; Zhong, Sheng-Hua; Halberda, Justin
2016-09-01
We address the challenges of how to model human perceptual grouping in random dot arrays and how perceptual grouping affects human number estimation in these arrays. We introduce a modeling approach relying on a modified k-means clustering algorithm to formally describe human observers' grouping behavior. We found that a default grouping window size of approximately 4° of visual angle describes human grouping judgments across a range of random dot arrays (i.e., items within 4° are grouped together). This window size was highly consistent across observers and images, and was also stable across stimulus durations, suggesting that the k-means model captured a robust signature of perceptual grouping. Further, the k-means model outperformed other models (e.g., CODE) at describing human grouping behavior. Next, we found that the more the dots in a display are clustered together, the more human observers tend to underestimate the numerosity of the dots. We demonstrate that this effect is independent of density, and the modified k-means model can predict human observers' numerosity judgments and underestimation. Finally, we explored the robustness of the relationship between clustering and dot number underestimation and found that the effects of clustering remain, but are greatly reduced, when participants receive feedback on every trial. Together, this work suggests some promising avenues for formal models of human grouping behavior, and it highlights the importance of a 4° window of perceptual grouping. Lastly, it reveals a robust, somewhat plastic, relationship between perceptual grouping and number estimation. Copyright © 2015 Elsevier Ltd. All rights reserved.
Farid, Huma; Khan, Farhan Raza; Rahman, Munawar
2013-03-01
This study aimed to compare the frequency of ProTaper rotary instrument fracture with rotary (conventional) and hybrid (rotary and hand files) canal preparation techniques. Secondary objectives were to determine whether there was an association of ProTaper file fracture with the canal curvature and to compare the mean time required for canal preparation in the two techniques. An in vitro experiment was conducted on 216 buccal canals of extracted maxillary and mandibular first molars. After creating an access cavity and a glide path for each canal, a periapical radiograph was taken and the canal curvature was measured with Schneider's technique. The canals were then randomly divided into Group A (rotary technique) and Group B (hybrid technique). The length of ProTaper files were measured before and after each canal preparation. Time taken for each canal preparation was recorded. A total of seven ProTaper files fractured in Group A (P=0.014) in canals with a curvature >25 degrees (P<0.001). The mean time taken for preparation of the root canals was 104.04 sec (± 55.7 sec) in Group A versus 122.88 sec (± 41.67 sec) in Group B (P=0.007). In the teeth studied, the hybrid technique of root canal preparation with ProTaper rotary files, although time consuming, was safer in canals having a curvature greater than 25 degrees.
Topçuoğlu, H S; Üstün, Y; Akpek, F; Aktı, A; Topçuoğlu, G
2016-09-01
To evaluate the effect of coronal flaring on the amount of debris extruded apically during root canal preparation using the Reciproc, WaveOne (WO) and OneShape (OS) single-file systems. Ninety extracted single-rooted mandibular incisor teeth were randomly assigned to six groups (n = 15 for each group) for canal instrumentation. Endodontic access cavities were prepared in each tooth. In three of the six groups, coronal flaring was not performed; coronal flaring was performed with Gates-Glidden drills on all teeth in the remaining three groups. The canals were then instrumented with one or other of the following single-file instrument systems: Reciproc, WO and OS. Debris extruded apically during instrumentation was collected into pre-weighed Eppendorf tubes. The tubes were then stored in an incubator at 70 °C for 5 days. The weight of the dry extruded debris was established by subtracting the pre-instrumentation and post-instrumentation weight of the Eppendorf tubes for each group. Data were analysed using one-way analysis of variance (anova) and Tukey's post hoc tests (P = 0.05). Reciproc and WO files without coronal flaring produced significantly more debris compared with the other groups (P < 0.05). There was no significant difference in apical extrusion of debris amongst the other groups (P > 0.05). All single-file systems caused apical extrusion of debris. Performing coronal flaring prior to canal preparation reduced the amount of apically extruded debris when using Reciproc or WO systems. © 2015 International Endodontic Journal. Published by John Wiley & Sons Ltd.
VizieR Online Data Catalog: SDSS Stripe 82 VLA 1-2GHz survey (Heywood+, 2016)
NASA Astrophysics Data System (ADS)
Heywood, I.; Jarvis, M. J.; Baker, A. J.; Bannister, K. W.; Carvalho, C. S.; Hardcastle, M.; Hilton, M.; Moodley, K.; Smirnov, O. M.; Smith, D. J. B.; White, S. V.; Wollack, E. J.
2017-11-01
The data (Project code: 13B-272) were taken with the array in the CnB configuration. Standard wide-band mode was employed with the correlator splitting the 1-2GHz of frequency coverage into 16 spectral windows (SPWs) with 64x1MHz channels each, and an integration time per visibility point of 3s. A total of 1368 target pointings were scheduled, 608 and 760 in the eastern and western regions, respectively, coincident with the two eastern and western areas of the existing Hodge et al. (2011, Cat. J/AJ/142/3) data. (2 data files).
Molmil: a molecular viewer for the PDB and beyond.
Bekker, Gert-Jan; Nakamura, Haruki; Kinjo, Akira R
2016-01-01
We have developed a new platform-independent web-based molecular viewer using JavaScript and WebGL. The molecular viewer, Molmil, has been integrated into several services offered by Protein Data Bank Japan and can be easily extended with new functionality by third party developers. Furthermore, the viewer can be used to load files in various formats from the user's local hard drive without uploading the data to a server. Molmil is available for all platforms supporting WebGL (e.g. Windows, Linux, iOS, Android) from http://gjbekker.github.io/molmil/. The source code is available at http://github.com/gjbekker/molmil under the LGPLv3 licence.
VizieR Online Data Catalog: The second Konus-Wind short GRB catalog (Svinkin+, 2016)
NASA Astrophysics Data System (ADS)
Svinkin, D. S.; Frederiks, D. D.; Aptekar, R. L.; Golenetskii, S. V.; Pal'Shin, V. D.; Oleynik, P. P.; Tsvetkova, A. E.; Ulanov, M. V.; Cline, T. L.; Hurley, K.
2016-07-01
Between 1994 November and 2010 December, the Konus-Wind spectrometer (KW; see section 2 for details) detected 1939 GRBs in the triggered mode, 295 of which were classified as short-duration GRBs or short bursts with extended emission (EE). The count rates are recorded in three energy windows G1 (13-50keV), G2 (50-200keV), and G3 (200-760keV) with 2.944s time resolution. The catalog includes about twice the number of bursts as the first Konus catalog of short GRBs (Mazets et al. arXiv:astro-ph/0209219). (6 data files).
A low-cost universal cumulative gating circuit for small and large animal clinical imaging
NASA Astrophysics Data System (ADS)
Gioux, Sylvain; Frangioni, John V.
2008-02-01
Image-assisted diagnosis and therapy is becoming more commonplace in medicine. However, most imaging techniques suffer from voluntary or involuntary motion artifacts, especially cardiac and respiratory motions, which degrade image quality. Current software solutions either induce computational overhead or reject out-of-focus images after acquisition. In this study we demonstrate a hardware-only gating circuit that accepts multiple, pseudo-periodic signals and produces a single TTL (0-5 V) imaging window of accurate phase and period. The electronic circuit Gerber files described in this article and the list of components are available online at www.frangionilab.org.
VR Lab ISS Graphics Models Data Package
NASA Technical Reports Server (NTRS)
Paddock, Eddie; Homan, Dave; Bell, Brad; Miralles, Evely; Hoblit, Jeff
2016-01-01
All the ISS models are saved in AC3D model format which is a text based format that can be loaded into blender and exported to other formats from there including FBX. The models are saved in two different levels of detail, one being labeled "LOWRES" and the other labeled "HIRES". There are two ".str" files (HIRES _ scene _ load.str and LOWRES _ scene _ load.str) that give the hierarchical relationship of the different nodes and the models associated with each node for both the "HIRES" and "LOWRES" model sets. All the images used for texturing are stored in Windows ".bmp" format for easy importing.
[Glossary of terms used by radiologists in image processing].
Rolland, Y; Collorec, R; Bruno, A; Ramée, A; Morcet, N; Haigron, P
1995-01-01
We give the definition of 166 words used in image processing. Adaptivity, aliazing, analog-digital converter, analysis, approximation, arc, artifact, artificial intelligence, attribute, autocorrelation, bandwidth, boundary, brightness, calibration, class, classification, classify, centre, cluster, coding, color, compression, contrast, connectivity, convolution, correlation, data base, decision, decomposition, deconvolution, deduction, descriptor, detection, digitization, dilation, discontinuity, discretization, discrimination, disparity, display, distance, distorsion, distribution dynamic, edge, energy, enhancement, entropy, erosion, estimation, event, extrapolation, feature, file, filter, filter floaters, fitting, Fourier transform, frequency, fusion, fuzzy, Gaussian, gradient, graph, gray level, group, growing, histogram, Hough transform, Houndsfield, image, impulse response, inertia, intensity, interpolation, interpretation, invariance, isotropy, iterative, JPEG, knowledge base, label, laplacian, learning, least squares, likelihood, matching, Markov field, mask, matching, mathematical morphology, merge (to), MIP, median, minimization, model, moiré, moment, MPEG, neural network, neuron, node, noise, norm, normal, operator, optical system, optimization, orthogonal, parametric, pattern recognition, periodicity, photometry, pixel, polygon, polynomial, prediction, pulsation, pyramidal, quantization, raster, reconstruction, recursive, region, rendering, representation space, resolution, restoration, robustness, ROC, thinning, transform, sampling, saturation, scene analysis, segmentation, separable function, sequential, smoothing, spline, split (to), shape, threshold, tree, signal, speckle, spectrum, spline, stationarity, statistical, stochastic, structuring element, support, syntaxic, synthesis, texture, truncation, variance, vision, voxel, windowing.
Scarselli, A; Leva, A; Campo, G; Marconi, M; Nesti, M; Erba, P
2005-01-01
The Italian Institute for Occupational Prevention and Safety (ISPESL) carried out a register of enterprises operating in industry, services and agriculture sector to provide information on their location, economical activity and occupational data. This database has been built merging administrative files from the National Institute of Social Security (INPS) and the Computer Science Society of Italian Chambers of Commerce (InfoCamere). Enterprises have been classified by economic sector - in accordance with ISTAT (National Statistics Institute) "Ateco91" classification--and by accuracy level of the record linkage. In details, three different subsystems have been set up: (A) enterprises satisfying linkage; (B) enterprises in InfoCamere file not linked with INPS file; (C) enterprises in INPS file not linked with InfoCamere file. In the whole, 6.026.676 factories have been collected, of which 1.188.784 in group A, 4.543.091 in group B and 294.801 in group C. Establishing a database of information on industries may be useful to improve preventive programs and to plan health care surveillance systems.
Stereomicroscopic evaluation of dentinal defects induced by new rotary system: "ProTaper NEXT".
Shori, Deepa Deepak; Shenoi, Pratima Ramakrishna; Baig, Arshia R; Kubde, Rajesh; Makade, Chetana; Pandey, Swapnil
2015-01-01
The objective of this study was to evaluate dentinal defects formed by new rotary system - Protaper next™ (PTN). Sixty single-rooted premolars were selected. All specimens were decoronated and divided into four groups, each group having 15 specimens. Group I specimens were prepared by Hand K-files (Mani), Group II with ProTaper Universal (PT; Dentsply Maillefer), Group III with Hero Shaper (HS; Micro-Mega, Besancon, France), and Group IV with PTN (Dentsply Maillefer). Roots of each specimen were sectioned at 3, 6, and 9mm from the apex and were then viewed under a stereomicroscope to evaluate presence or absence of dentinal defects. In roots prepared with hand files (HFs) showed lowest percentage of dentinal defects (6.7%); whereas in roots prepared with PT, HS, and PTN it was 40, 66.7, and 26.7%, respectively. There was significant difference between the HS group and the PTN group (P < 0.05). All rotary files induced defects in root dentin, whereas the hand instruments induced minimal defects.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-30
... wide by 50 feet long by 30 feet deep; (3) the existing 50-foot-long by 20-foot-wide by 30-foot- deep... Commission's Web site ( http://www.ferc.gov/docs-filing/ferconline.asp ) under the ``eFiling'' link. For a... 20426. For more information on how to submit these types of filings please go to the Commission's Web...
Sikka, Kapil; Kairo, Arvind; Singh, Chirom Amit; Roy, T S; Lalwani, Sanjeev; Kumar, Rakesh; Thakar, Alok; Sharma, Suresh C
2017-09-01
To evaluate the extent of intracochlear damage by histologic assessment of cadaveric temporal bones after insertion of cochlear implants by: round window approach and cochleostomy approach. Cochlear implantation was performed by transmastoid facial recess approach in 10 human cadaveric temporal bones. In 5 temporal bones, electrode insertion was acheieved by round window approach and in the remaining 5 bones, by cochleostomy approach. The bones were fixed, decalcified, sectioned and studied histologically. Grading of insertion trauma was assessed. In the round window insertion group, 2 bones had to be excluded from the study: one was damaged during handling with electrode extrusion and another bone did not show any demonstrable identifiable cochlear structure. Out of the 3 temporal bones, a total of 35 sections were examined: 24 demonstrated normal cochlea, 4 had basilar membrane bulging and 7 had fracture of bony spiral lamina. In the cochleostomy group, histology of 2 bones had to be discarded due to lack of any identifiable inner ear structures. Out of the 3 bones studied, 18 sections were examined: only 3 were normal, 4 sections had some bulge in spiral lamina and 11 had fracture of bony spiral lamina. The fracture of spiral lamina and bulge of basement membrane proportion is relatively higher if we perform cochleostomy as compared to round window approach. Therefore, round window insertion is relatively less traumatic as compared to cochleostomy. However, our sample size was very small and a study with a larger sample is required to further validate these findings.
Jiam, Nicole T; Limb, Charles J
2016-09-01
To evaluate incidence of interscalar excursions between round window (RW) and cochleostomy approaches for cochlear implant (CI) insertion. This was a retrospective case-comparison. Flat-panel CT (FPCT) scans for 8 CI users with Med-El standard length electrode arrays were collected. Surgical technique was identified by a combination of operative notes and FPCT imaging. Four cochleae underwent round window insertion and 4 cochleae underwent cochleostomy approaches anterior and inferior to the round window. In our pilot study, cochleostomy approaches were associated with a higher likelihood of interscalar excursion. Within the cochleostomy group, we found 29% of electrode contacts (14 of 48 electrodes) to be outside the scala tympani. On the other hand, 8.5% of the electrode contacts (4 of 47 electrodes) in the round window insertion group were extra-scalar to the scala tympani. These displacements occurred at a mean angle of occurrence of 364° ± 133°, near the apex of the cochlea. Round window electrode displacements tend to localize at angle of occurrences of 400° or greater. Cochleostomy electrodes occurred at an angle of occurrence of 19°-490°. Currently, the optimal surgical approach for standard CI electrode insertion is highly debated, to a certain extent due to a lack of post-operative assessment of intracochlear electrode contact. Based on our preliminary findings, cochleostomy approach is associated with an increased likelihood of interscalar excursions, and these findings should be further evaluated with future prospective studies.
Topçuoğlu, Hüseyin Sinan; Düzgün, Salih; Akpek, Firdevs; Topçuoğlu, Gamze
2016-11-01
This study evaluated the effect of creating a glide path and apical preparation size on the incidence of apical cracks during canal preparation in mandibular molar teeth with curved canals. One hundred and forty extracted teeth were used. The teeth were randomly assigned to one control group or six experimental groups (n = 20 per group) for canal preparation. No preparation was performed on teeth in the control group. In three of the six experimental groups, a glide path was not created; a glide path was created on the curved mesial canals of all teeth in the remaining three experimental groups. All teeth in experimental groups were then instrumented with the following systems: Reciproc, WaveOne (WO), and ProTaper Next (PTN). Digital images of the apical root surfaces of these teeth were recorded before preparation, after instrumentation with size 25 files, and after instrumentation with size 40 files. The images were then inspected for the presence of any new apical cracks and propagation. There was no significant difference between the experimental groups during canal preparation using size 25 files (p > 0.05). Reciproc and WO caused more new apical cracks than did PTN during canal preparation using size 40 files (p < 0.05). However, canal preparation using size 40 files did not cause propagation of existing cracks (p > 0.05). Performing a glide path prior to canal preparation did not change the incidence of apical crack during preparation. Additionally, increasing apical preparation size may increase the incidence of apical crack during canal preparation. SCANNING 38:585-590, 2016. © 2016 Wiley Periodicals, Inc. © Wiley Periodicals, Inc.
Chen, Xiao-bo; Chen, Chen; Liang, Yu-hong
2016-02-18
To evaluate the efficacy and security of two type of rotary nickel titanium system (Twisted File and ProTaper Universal) for root canal preparation based on micro-computed tomography(micro-CT). Twenty extracted molars (including 62 canals) were divided into two experimental groups and were respectively instrumented using Twisted File rotary nickel titanium system (TF) and ProTaper Universal rotary nickel titanium system (PU) to #25/0.08 following recommended protocol. Time for root canal instrumentation (accumulation of time for every single file) was recorded. The 0-3 mm root surface from apex was observed under an optical stereomicroscope at 25 × magnification. The presence of crack line was noted. The root canals were scanned with micro-CT before and after root canal preparation. Three-dimensional shape images of canals were reconstructed, calculated and evaluated. The amount of canal central transportation of the two groups was calculated and compared. The shorter preparation time [(0.53 ± 0.14) min] was observed in TF group, while the preparation time of PU group was (2.06 ± 0.39) min (P<0.05). In mid-root level, TF group shaping resulted in less canal center transportation than PU group [(0.070 ± 0.056) mm vs. (0.097 ± 0.084) mm, P<0.05]. No instrument separation was observed in both the groups. Cracks were not found in both the groups either based in micro-CT images or observation under an optical stereomicroscope at 25 × magnification. Compared with ProTaper Universal, Twisted File took less time in root canal preparation and exhibited better shaping ability, and less canal transportation.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-23
... SECURITIES AND EXCHANGE COMMISSION [File No. 500-1] Aspen Group Resources Corp., Commercial Concepts, Inc., Desert Health Products, Inc., Equalnet Communications Corp., Geneva Steel Holdings Corp... securities of Commercial Concepts, Inc. because it has not filed any periodic reports since the period ended...
8 CFR 207.5 - Waiting lists and priority handling.
Code of Federal Regulations, 2010 CFR
2010-01-01
... REFUGEES § 207.5 Waiting lists and priority handling. Waiting lists are maintained for each designated refugee group of special humanitarian concern. Each applicant whose application is accepted for filing by... filing is the priority date for purposes of case control. Refugees or groups of refugees may be selected...
Gastrointestinal and Other Cancers | Division of Cancer Prevention
[[{"fid":"181","view_mode":"default","fields":{"format":"default","field_file_image_alt_text[und][0][value]":"Gastrointestinal and Other Cancers Research Group Homepage Logo","field_file_image_title_text[und][0][value]":"Gastrointestinal and Other Cancers Research Group Homepage Logo","field_folder[und]":"15"},"type":"media","attributes":{"alt":"Gastrointestinal and Other
A Personal Development File: Self-Development among Business Studies Students.
ERIC Educational Resources Information Center
Estienne, Marion
1991-01-01
The Personal Development File involved undergraduate business students in exploring the present, envisioning the future, and bridging the gap within the framework of a support group. However, many students opposed the behavioral and attitudinal objectives involved, and negative group interaction caused some students to withdraw from the project.…
Alves, Vanessa de Oliveira; Bueno, Carlos Eduardo da Silveira; Cunha, Rodrigo Sanches; Pinheiro, Sérgio Luiz; Fontana, Carlos Eduardo; de Martin, Alexandre Sigrist
2012-01-01
Nickel-titanium rotary instruments reduce procedural errors and the time required to finish root canal preparation. The goal of this study was to evaluate the occurrences of apical transportation and canal aberrations produced with different instruments used to create a glide path in the preparation of curved root canals, namely manual K-files (Dentsply Maillefer, Ballaigues, Switzerland) and PathFile (Dentsply Maillefer) and Mtwo (Sweden and Martina, Padua, Italy) nickel-titanium rotary files. The mesial canals of 45 mandibular first and second molars (with curvature angles between 25° and 35°) were selected for this study. The specimens were divided randomly into 3 groups with 15 canals each, and canal preparation was performed by an endodontist using #10-15-20 K-type stainless steel manual files (group M), #13-16-19 PathFile rotary instruments (group PF), and #10-15-20 Mtwo rotary instruments (group MT). The double digital radiograph technique was used, pre- and postinstrumentation, to assess whether apical transportation and/or aberration in root canal morphology occurred. The initial and final images of the central axis of the canals were compared by superimposition through computerized analysis and with the aid of magnification. The specimens were analyzed by 3 evaluators, whose calibration was checked using the Kendall agreement test. No apical transportation or aberration in root canal morphology occurred in any of the teeth; therefore, no statistical analysis was conducted. Neither the manual instruments nor the PathFile or Mtwo rotary instruments used to create a glide path had any influence on the occurrence of apical transportation or produced any canal aberration. Copyright © 2012 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Using Pop-Up Windows to Improve Multimedia Learning
ERIC Educational Resources Information Center
Erhel, S.; Jamet, E.
2006-01-01
The aim of the present study is to evaluate the effects on learning of the spatial integration of textual information incorporated into illustrations in the form of pop-up windows that are opened by the user. Three groups of students viewed illustrated texts depicting the functioning of the heart and the replication of the AIDS virus either with…