Surface sampling for endotoxin assessment using electrostatic wiping cloths.
Thorne, Peter S; Metwali, Nervana; Avol, Ed; McConnell, Rob S
2005-07-01
Much of the cost of exposure assessment for studies of residential cohorts is in scheduling and travel time for field staff. One way to reduce costs is to simplify methods such that subjects can sample their own residence. Analysis of settled dust is being widely used for assessment of exposures to allergens, lead and pesticides and can also be used for endotoxins. While vacuum sampling is the most common surface sampling method, wipe sampling has the advantage that it can be readily performed by the resident when convenient and samples can then be mailed to researchers. Thus, we evaluated the feasibility of wipe sampling for endotoxin environmental assessment using electrostatic wipes with or without the use of disposable examination gloves. Multiple lots of six types of commercial wipes and eight types of gloves were extracted and analyzed for endotoxin content using the kinetic chromogenic Limulus amebocyte lysate assay. Wipes were compared across brands, between lots, within lots, between pairs depending on proximity to cardboard packaging, and in wipe tests with or without gloves. Collected dust samples of known concentration were also tested in spiking assays for endotoxin recovery. The most striking finding was the high variability of endotoxin contamination of both wipes and gloves across brands and between various lots. The content of endotoxin in unused gloves ranged from <1.5 to 5810 endotoxin units (EU). The range for unused wipes was 3.6-87.8 EU. Surfaces of equal loading and area were sampled using three types of cloths that had low initial endotoxin contamination. The cloths were very good at collecting dust and endotoxin could be assayed from aqueous extracts of the wipes. Samples collected using cloths with bare washed hands yielded higher endotoxin loading per mass of collected dust versus samples collected wearing endotoxin-free gloves. This demonstrated additional endotoxin loading from the subject's hand. This study shows that wipe sampling while wearing medical gloves can be an effective method for collecting and assessing endotoxin on surfaces, so long as each lot of wipes and gloves have been tested and determined to be low in endotoxin.
A LITERATURE REVIEW OF WIPE SAMPLING METHODS ...
Wipe sampling is an important technique for the estimation of contaminant deposition in buildings, homes, or outdoor surfaces as a source of possible human exposure. Numerousmethods of wipe sampling exist, and each method has its own specification for the type of wipe, wetting solvent, and determinative step to be used, depending upon the contaminant of concern. The objective of this report is to concisely summarize the findings of a literature review that was conducted to identify the state-of-the-art wipe sampling techniques for a target list of compounds. This report describes the methods used to perform the literature review; a brief review of wipe sampling techniques in general; an analysis of physical and chemical properties of each target analyte; an analysis of wipe sampling techniques for the target analyte list; and asummary of the wipe sampling techniques for the target analyte list, including existing data gaps. In general, no overwhelming consensus can be drawn from the current literature on how to collect a wipe sample for the chemical warfare agents, organophosphate pesticides, and other toxic industrial chemicals of interest to this study. Different methods, media, and wetting solvents have been recommended and used by various groups and different studies. For many of the compounds of interest, no specific wipe sampling methodology has been established for their collection. Before a wipe sampling method (or methods) can be established for the co
This SOP describes the method for collection of the food preparation surface wipe samples for the measurement of persistent organic pollutants (POP). This method uses a wipe to collect POP residues from a surface where a study participant prepares food the most often (i.e., kitch...
U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--PESTICIDES IN DERMAL ANALYTICAL RESULTS
The Pesticides in Dermal Wipes data set contains analytical results for measurements of up to 8 pesticides in 86 dermal wipe samples over 86 households. Each sample was collected from the primary respondent within each household. The Dermal/Pesticide hand wipe was collected 7 d...
NHEXAS PHASE I MARYLAND STUDY--PESTICIDES IN DERMAL WIPES ANALYTICAL RESULTS
The Pesticides in Dermal Wipe Samples data set contains analytical results for measurements of up to 8 pesticides in 40 dermal wipe samples over 40 households. Each sample was collected from the primary respondent within each household. The sampling period occurred on the last ...
The purpose of this SOP is to describe the procedures for collecting surface wipe samples inside a home for analysis of either metals or pesticides. This procedure covers the preparation of the surface wipe material and field activities. This protocol was followed to ensure con...
NHEXAS PHASE I MARYLAND STUDY--METALS IN DERMAL WIPES ANALYTICAL RESULTS
The Metals in Dermal Wipe Samples data set contains analytical results for measurements of up to 4 metals in 343 dermal wipe samples over 80 households. Each sample was collected from the primary respondent within each household. The sampling period occurred on the first day of...
Efficiency of wipe sampling on hard surfaces for pesticides and PCB residues in dust.
Cettier, Joane; Bayle, Marie-Laure; Béranger, Rémi; Billoir, Elise; Nuckols, John R; Combourieu, Bruno; Fervers, Béatrice
2015-02-01
Pesticides and polychlorinated biphenyls (PCBs) are commonly found in house dust and have been described as a valuable matrix to assess indoor pesticide and PCB contamination. The aim of this study was to assess the efficiency and precision of cellulose wipe for collecting 48 pesticides, eight PCBs, and one synergist at environmental concentrations. First, the efficiency and repeatability of wipe collection were determined for pesticide and PCB residues that were directly spiked onto three types of household floors (tile, laminate, and hardwood). Second, synthetic dust was used to assess the capacity of the wipe to collect dust. Third, we assessed the efficiency and repeatability of wipe collection of pesticides and PCB residues that was spiked onto synthetic dust and then applied to tile. In the first experiment, the overall collection efficiency was highest on tile (38%) and laminate (40%) compared to hardwood (34%), p<0.001. The second experiment confirmed that cellulose wipes can efficiently collect dust (82% collection efficiency). The third experiment showed that the overall collection efficiency was higher in the presence of dust (72% vs. 38% without dust, p<0.001). Furthermore, the mean repeatability also improved when compounds were spiked onto dust (<30% for the majority of compounds). To our knowledge, this is the first study to assess the efficiency of wipes as a sampling method using a large number of compounds at environmental concentrations and synthetic dust. Cellulose wipes appear to be efficient to sample the pesticides and PCBs that adsorb onto dust on smooth and hard surfaces. Copyright © 2014 Elsevier B.V. All rights reserved.
The purpose of this SOP is to describe the procedures for collecting surface wipe samples inside a home for analysis of either metals or pesticides. This procedure covers the preparation of the surface wipe material and field activities. This protocol was followed to ensure con...
The purpose of this SOP is to describe the procedures for collecting a dermal wipe sample from a participant's hands for the measurement of pesticide or metal residues on the skin. This procedure covers the preparation of the dermal wipe material and field activities. This prot...
NHEXAS PHASE I ARIZONA STUDY--METALS IN DERMAL WIPES ANALYTICAL RESULTS
The Metals in Dermal Wipes data set contains analytical results for measurements of up to 11 metals in 179 dermal wipe samples over 179 households. Each sample was collected from the primary respondent within each household during Stage III of the NHEXAS study. The sampling per...
Ceballos, Diana; King, Bradley; Beaucham, Catherine; Brueck, Scott E.
2015-01-01
Closed-face 37-millimeter (mm) polystyrene cassettes are often used for exposure monitoring of metal particulates. Several methods have been proposed to account for the wall loss in air sampling cassettes, including rinsing, wiping, within-cassette dissolution, and an internal capsule fused to the filter that could be digested with the filter. Until internal capsules replace filters, other methods for assessing wall losses may be considered. To determine if rinsing and wiping or wiping alone is adequate to determine wall losses on cassettes, we collected 54 full-shift area air samples at a battery recycling facility. We collected six replicate samples at three locations within the facility for 3 consecutive days. The wall losses of three replicate cassettes from each day-location were analyzed following a rinse and two consecutive wipes. The wall losses of the other three replicates from each day-location were analyzed following two consecutive wipes only. Mixed-cellulose ester membrane filter, rinse, and wipes were analyzed separately following NIOSH Method 7303. We found an average of 29% (range: 8%–54%) recovered lead from the cassette walls for all samples. We also found that rinsing prior to wiping the interior cassette walls did not substantially improve recovery of wall losses compared to wiping alone. A rinse plus one wipe recovered on average 23% (range: 13%–33%) of the lead, while one wipe alone recovered on average 21% (range: 16%–22%). Similarly we determined that a second wipe did not provide substantial additional recovery of lead (average: 4%, range: 0.4%–19%) compared to the first wipe disregarding the rinse (average: 18%, range: 4%–39%). We concluded that when an internal capsule is not used, wall losses of lead dust in air sampling cassettes can be adequately recovered by wiping the internal wall surfaces of the cassette with a single wipe. PMID:26125330
The purpose of this SOP is to describe the procedures for collecting a dermal wipe sample from a participant's hands for the measurement of pesticide or metal residues on the skin. This procedure covers the preparation of the dermal wipe material and field activities. This prot...
Colling Wipe Samples for VX Analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Koester, C; Hoppes, W G
2010-02-11
This standard operating procedure (SOP) provides uniform procedures for the collection of wipe samples of VX residues from surfaces. Personnel may use this procedure to collect and handle wipe samples in the field. Various surfaces, including building materials (wood, metal, tile, vinyl, etc.) and equipment, may be sampled based on this procedure. The purpose of such sampling is to determine whether or not the relevant surfaces are contaminated, to determine the extent of their contamination, to evaluate the effectiveness of decontamination procedures, and to determine the amount of contaminant that might present as a contact hazard.
NHEXAS PHASE I ARIZONA STUDY--PESTICIDES IN DERMAL WIPES ANALYTICAL RESULTS
The Pesticides in Dermal Wipes data set contains analytical results for measurements of up to 3 pesticides in 177 dermal wipe samples over 177 households. Each sample was collected from the primary respondent within each household during Stage III of the NHEXAS study. The Derma...
Estimating dermal transfer from PCB-contaminated porous surfaces.
Slayton, T M; Valberg, P A; Wait, A D
1998-06-01
Health risks posed by dermal contact with PCB-contaminated porous surfaces have not been directly demonstrated and are difficult to estimate indirectly. Surface contamination by organic compounds is commonly assessed by collecting wipe samples with hexane as the solvent. However, for porous surfaces, hexane wipe characterization is of limited direct use when estimating potential human exposure. Particularly for porous surfaces, the relationship between the amount of organic material collected by hexane and the amount actually picked up by, for example, a person's hand touch is unknown. To better mimic PCB pickup by casual hand contact with contaminated concrete surfaces, we used alternate solvents and wipe application methods that more closely mimic casual dermal contact. Our sampling results were compared to PCB pickup using hexane-wetted wipes and the standard rubbing protocol. Dry and oil-wetted samples, applied without rubbing, picked up less than 1% of the PCBs picked up by the standard hexane procedure; with rubbing, they picked up about 2%. Without rubbing, saline-wetted wipes picked up 2.5%; with rubbing, they picked up about 12%. While the nature of dermal contact with a contaminated surface cannot be perfectly reproduced with a wipe sample, our results with alternate wiping solvents and rubbing methods more closely mimic hand contact than the standard hexane wipe protocol. The relative pickup estimates presented in this paper can be used in conjunction with site-specific PCB hexane wipe results to estimate dermal pickup rates at sites with PCB-contaminated concrete.
Goeman, Valerie R; Tinkler, Stacy H; Hammac, G Kenitra; Ruple, Audrey
2018-04-01
Environmental surveillance for Salmonella enterica can be used for early detection of contamination; thus routine sampling is an integral component of infection control programs in hospital environments. At the Purdue University Veterinary Teaching Hospital (PUVTH), the technique regularly employed in the large animal hospital for sample collection uses sterile gauze sponges for environmental sampling, which has proven labor-intensive and time-consuming. Alternative sampling methods use Swiffer brand electrostatic wipes for environmental sample collection, which are reportedly effective and efficient. It was hypothesized that use of Swiffer wipes for sample collection would be more efficient and less costly than the use of gauze sponges. A head-to-head comparison between the 2 sampling methods was conducted in the PUVTH large animal hospital and relative agreement, cost-effectiveness, and sampling efficiency were compared. There was fair agreement in culture results between the 2 sampling methods, but Swiffer wipes required less time and less physical effort to collect samples and were more cost-effective.
Lab Analysis of Dust Wipe Samples
Dust wipe samples collected on residential properties near the fenceline of KCBX North and South Terminals in Chicago, which store and handle pet coke, were analyzed for polycyclic aromatic hydrocarbons (PAHs) and trace metals and minerals.
Comparison of Wipe Materials and Wetting Agents for Pesticide Residue Collection from Hard Surfaces
Deziel, Nicole C.; Viet, Susan M.; Rogers, John W.; Camann, David E.; Marker, David A.; Heikkinen, Maire S. A.; Yau, Alice Y.; Stout, Daniel M.; Dellarco, Michael
2011-01-01
Different wipe materials and wetting agents have been used to collect pesticide residues from surfaces, but little is known about their comparability. To inform the selection of a wipe for the National Children’s Study, the analytical feasibility, collection efficiency, and precision of Twillwipes wetted with isopropanol (TI), Ghost Wipes (GW), and Twillwipes wetted with water (TW), and were evaluated. Wipe samples were collected from stainless steel surfaces spiked with high and low concentrations of 27 insecticides, including organochlorines, organophosphates, and pyrethroids. Samples were analyzed by GC/MS/SIM. No analytical interferences were observed for any of the wipes. The mean percent collection efficiencies across all pesticides for the TI, GW, and TW were 69.3%, 31.1%, and 10.3% at the high concentration, respectively, and 55.6%, 22.5%, and 6.9% at the low concentration, respectively. The collection efficiencies of the TI were significantly greater than that of GW or TW (p<0.0001). Collection efficiency also differed significantly by pesticide (p<0.0001) and spike concentration (p<0.0001). The pooled coefficients of variation (CVs) of the collection efficiencies for the TI, GW, and TW at high concentration were 0.08, 0.17, and 0.24, respectively. The pooled CV of the collection efficiencies for the TI, GW, and TW at low concentration were 0.15, 0.19, and 0.36, respectively. The TI had significantly lower CVs than either of the other two wipes (p=0.0008). Though the TI was superior in terms of both accuracy and precision, it requires multiple preparation steps, which could lead to operational challenges in a large-scale study. PMID:21816452
40 CFR 761.243 - Standard wipe sample method and size.
Code of Federal Regulations, 2010 CFR
2010-07-01
..., AND USE PROHIBITIONS Determining a PCB Concentration for Purposes of Abandonment or Disposal of Natural Gas Pipeline: Selecting Sample Sites, Collecting Surface Samples, and Analyzing Standard PCB Wipe.../Rinse Cleanup as Recommended by the Environmental Protection Agency PCB Spill Cleanup Policy,” dated...
Bennett, D. H.; Moran, R. E.; Wu, X. (May); Tulve, N. S.; Clifton, M. S.; Colón, M.; Weathers, W.; Sjödin, A.; Jones, R.; Hertz-Picciotto, I.
2016-01-01
Polybrominated diphenyl ethers (PBDEs) are used as flame retardants in furniture foam, electronics, and other home furnishings. A field study was conducted that enrolled 139 households from California, which has had more stringent flame retardant requirements than other countries and areas. The study collected passive air, floor and indoor window surface wipes, and dust samples (investigator collected using an HVS3 and vacuum cleaner) in each home. PentaBDE and BDE209 were detected in the majority of the dust samples and many floor wipe samples, but the detection in air and window wipe samples was relatively low. Concentrations of each PBDE congener in different indoor environmental media were moderately correlated, with correlation coefficients ranging between 0.42 and 0.68. Correlation coefficients with blood levels were up to 0.65 and varied between environmental media and age group. Both investigator-collected dust and floor wipes were correlated with serum levels for a wide range of congeners. These two sample types also had a relatively high fraction of samples with adequate mass for reliable quantification. In 42 homes, PBDE levels measured in the same environmental media in the same home 1 year apart were statistically correlated (correlation coefficients: 0.57–0.90), with the exception of BDE209 which was not well correlated longitudinally. PMID:24832910
Associations between PBDEs in Office Air, Dust, and Surface Wipes
Watkins, Deborah J.; McClean, Michael D.; Fraser, Alicia J.; Weinberg, Janice; Stapleton, Heather M.; Webster, Thomas F.
2013-01-01
Increased use of flame-retardants in office furniture may increase exposure to PBDEs in the office environment. However, partitioning of PBDEs within the office environment is not well understood. Our objectives were to examine relationships between concurrent measures of PBDEs in office air, floor dust, and surface wipes. We collected air, dust, and surface wipe samples from 31 offices in Boston, MA. Correlation and linear regression were used to evaluate associations between variables. Geometric mean (GM) concentrations of individual BDE congeners in air and congener specific octanol-air partition coefficients (Koa) were used to predict GM concentrations in dust and surface wipes and compared to the measured concentrations. GM concentrations of PentaBDEs in office air, dust, and surface wipes were 472 pg/m3, 2411 ng/g, and 77 pg/cm2, respectively. BDE209 was detected in 100% of dust samples (GM=4202 ng/g), 93% of surface wipes (GM=125 pg/cm2), and 39% of air samples. PentaBDEs in dust and air were moderately correlated with each other (r=0.60, p=0.0003), as well as with PentaBDEs in surface wipes (r=0.51, p=0.003 for both dust and air). BDE209 in dust was correlated with BDE209 in surface wipes (r=0.69, p=0.007). Building (three categories) and PentaBDEs in dust were independent predictors of PentaBDEs in both air and surface wipes, together explaining 50% (p=0.0009) and 48% (p=0.001) of the variation respectively. Predicted and measured concentrations of individual BDE congeners were highly correlated in dust (r=0.98, p<0.0001) and surface wipes (r=0.94, p=002). BDE209 provided an interesting test of this equilibrium partitioning model as it is a low volatility compound. Associations between PentaBDEs in multiple sampling media suggest that collecting dust or surface wipes may be a convenient method of characterizing exposure in the indoor environment. The volatility of individual congeners, as well as physical characteristics of the indoor environment, influence relationships between PBDEs in air, dust, and surface wipes. PMID:23797055
Bennett, D H; Moran, R E; Wu, X May; Tulve, N S; Clifton, M S; Colón, M; Weathers, W; Sjödin, A; Jones, R; Hertz-Picciotto, I
2015-04-01
Polybrominated diphenyl ethers (PBDEs) are used as flame retardants in furniture foam, electronics, and other home furnishings. A field study was conducted that enrolled 139 households from California, which has had more stringent flame retardant requirements than other countries and areas. The study collected passive air, floor and indoor window surface wipes, and dust samples (investigator collected using an HVS3 and vacuum cleaner) in each home. PentaBDE and BDE209 were detected in the majority of the dust samples and many floor wipe samples, but the detection in air and window wipe samples was relatively low. Concentrations of each PBDE congener in different indoor environmental media were moderately correlated, with correlation coefficients ranging between 0.42 and 0.68. Correlation coefficients with blood levels were up to 0.65 and varied between environmental media and age group. Both investigator-collected dust and floor wipes were correlated with serum levels for a wide range of congeners. These two sample types also had a relatively high fraction of samples with adequate mass for reliable quantification. In 42 homes, PBDE levels measured in the same environmental media in the same home 1 year apart were statistically correlated (correlation coefficients: 0.57-0.90), with the exception of BDE209 which was not well correlated longitudinally. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--METALS IN DERMAL ANALYTICAL RESULTS
The Metals in Dermal Wipes data set contains analytical results for measurements of up to 11 metals in 86 dermal wipe samples over 86 households. Each sample was collected from the primary respondent within each household. The sampling period occurred on the first day of the fi...
40 CFR 761.310 - Collecting the sample.
Code of Federal Regulations, 2013 CFR
2013-07-01
... standard wipe test as defined in § 761.123 to sample one 10 centimeter by 10 centimeter square (100 cm2) area to represent surface area PCB concentrations of each square meter or fraction of a square meter of... wipe test, only sample the entire area, rather than 10 centimeter by 10 centimeter squares. ...
40 CFR 761.310 - Collecting the sample.
Code of Federal Regulations, 2011 CFR
2011-07-01
... standard wipe test as defined in § 761.123 to sample one 10 centimeter by 10 centimeter square (100 cm2) area to represent surface area PCB concentrations of each square meter or fraction of a square meter of... wipe test, only sample the entire area, rather than 10 centimeter by 10 centimeter squares. ...
40 CFR 761.310 - Collecting the sample.
Code of Federal Regulations, 2014 CFR
2014-07-01
... standard wipe test as defined in § 761.123 to sample one 10 centimeter by 10 centimeter square (100 cm2) area to represent surface area PCB concentrations of each square meter or fraction of a square meter of... wipe test, only sample the entire area, rather than 10 centimeter by 10 centimeter squares. ...
40 CFR 761.310 - Collecting the sample.
Code of Federal Regulations, 2012 CFR
2012-07-01
... standard wipe test as defined in § 761.123 to sample one 10 centimeter by 10 centimeter square (100 cm2) area to represent surface area PCB concentrations of each square meter or fraction of a square meter of... wipe test, only sample the entire area, rather than 10 centimeter by 10 centimeter squares. ...
40 CFR 761.310 - Collecting the sample.
Code of Federal Regulations, 2010 CFR
2010-07-01
... standard wipe test as defined in § 761.123 to sample one 10 centimeter by 10 centimeter square (100 cm2) area to represent surface area PCB concentrations of each square meter or fraction of a square meter of... wipe test, only sample the entire area, rather than 10 centimeter by 10 centimeter squares. ...
Brown, Gary S.; Betty, Rita G.; Brockmann, John E.; Lucero, Daniel A.; Souza, Caroline A.; Walsh, Kathryn S.; Boucher, Raymond M.; Tezak, Mathew; Wilson, Mollye C.; Rudolph, Todd
2007-01-01
Polyester-rayon blend wipes were evaluated for efficiency of extraction and recovery of powdered Bacillus atrophaeus spores from stainless steel and painted wallboard surfaces. Method limits of detection were also estimated for both surfaces. The observed mean efficiency of polyester-rayon blend wipe recovery from stainless steel was 0.35 with a standard deviation of ±0.12, and for painted wallboard it was 0.29 with a standard deviation of ±0.15. Evaluation of a sonication extraction method for the polyester-rayon blend wipes produced a mean extraction efficiency of 0.93 with a standard deviation of ±0.09. Wipe recovery quantitative limits of detection were estimated at 90 CFU per unit of stainless steel sample area and 105 CFU per unit of painted wallboard sample area. The method recovery efficiency and limits of detection established in this work provide useful guidance for the planning of incident response environmental sampling following the release of a biological agent such as Bacillus anthracis. PMID:17122390
Brown, Gary S; Betty, Rita G; Brockmann, John E; Lucero, Daniel A; Souza, Caroline A; Walsh, Kathryn S; Boucher, Raymond M; Tezak, Mathew; Wilson, Mollye C; Rudolph, Todd
2007-02-01
Polyester-rayon blend wipes were evaluated for efficiency of extraction and recovery of powdered Bacillus atrophaeus spores from stainless steel and painted wallboard surfaces. Method limits of detection were also estimated for both surfaces. The observed mean efficiency of polyester-rayon blend wipe recovery from stainless steel was 0.35 with a standard deviation of +/-0.12, and for painted wallboard it was 0.29 with a standard deviation of +/-0.15. Evaluation of a sonication extraction method for the polyester-rayon blend wipes produced a mean extraction efficiency of 0.93 with a standard deviation of +/-0.09. Wipe recovery quantitative limits of detection were estimated at 90 CFU per unit of stainless steel sample area and 105 CFU per unit of painted wallboard sample area. The method recovery efficiency and limits of detection established in this work provide useful guidance for the planning of incident response environmental sampling following the release of a biological agent such as Bacillus anthracis.
On wiping the interior walls of 37-mm closed-face cassettes: an OSHA perspective.
Hendricks, Warren; Stones, Fern; Lillquist, Dean
2009-12-01
As early as 1976, Occupational Safety and Health Administration (OSHA) methods for analyzing metal samples collected using 37-mm polystyrene closed-face cassettes specified that any loose dust be transferred from the cassette to the digestion vessel, that the cassette be rinsed, and that, if necessary, the cassette be wiped out to help ensure that all particles that enter the cassette are included along with the filter as part of the sample for analysis. OSHA analytical methods for metal analysis were recently revised to explicitly require cassette wiping for all metal samples. This change was based on policy that any material entering the collection device constitutes part of the sample and on OSHA Salt Lake Technical Center research showing that invisible residue on the cassette walls can significantly contribute to the total sample results reported. OSHA procedures are consistent with guidance given in the NIOSH Manual of Analytical Methods. This guidance concludes that internal deposits in sampling cassettes should be included in the analysis and that one way to accomplish this would be to wipe or wash the internal surfaces of the cassette and include the material along with the filter for analysis.
EVALUATING COMMERCIALLY AVAILABLE DERMAL ...
As the Human Exposure Program focuses on the exposure of children to pesticides, there are concerns about the effect, or perceived effect, of components of the sampling procedure on the health and well-being of the infant and the ability to collect pesticide residues. One concern involves the materials in wipes used to collect pesticide residues or other contact materials on the skin. In recent studies (e.g., National Human Exposure Assessment Survey; NHEXAS), isopropyl alcohol has been used as a solvent in conjunction with a cloth wipe to obtain samples from the hands of adults and children. Although isopropyl alcohol is generally considered innocuous, the use of commercially available products could eliminate concerns about exposure to alcohol. A few studies have evaluated the potential of commercially available baby wipes to collect personal exposure samples for metals research, but not for the area of pesticide research (Millson et al., 1994; Campbell et al., 1993; Lichtenwalner et al., 1993). Therefore, there is a need to evaluate the potential for using commercially available baby wipes for collecting pesticide samples from skin and other surfaces. Another concern involves establishing a convenient and safe method for assessing overall dermal exposure for children, especially for those in crawling stage. One route that the U .S. Environmental Protection Agency (EPA) would like to investigate is the use of cotton body suits (infant sleepers) as an indicator
Hammond, Duane; Garcia, Alberto; Feng, H Amy
2011-07-01
A utility-scale wind turbine blade manufacturing plant requested assistance from the National Institute for Occupational Safety and Health (NIOSH) in controlling worker exposures to styrene at a plant that produced 37 and 42 m long fiber-reinforced wind turbine blades. The plant requested NIOSH assistance because previous air sampling conducted by the company indicated concerns about peak styrene concentrations when workers entered the confined space inside of the wind turbine blade. NIOSH researchers conducted two site visits and collected personal breathing zone and area air samples while workers performed the wind turbine blade manufacturing tasks of vacuum-assisted resin transfer molding (VARTM), gelcoating, glue wiping, and installing the safety platform. All samples were collected during the course of normal employee work activities and analyzed for styrene using NIOSH Method 1501. All sampling was task based since full-shift sampling from a prior Occupational Safety and Health Administration (OSHA) compliance inspection did not show any exposures to styrene above the OSHA permissible exposure limit. During the initial NIOSH site visit, 67 personal breathing zone and 18 area air samples were collected while workers performed tasks of VARTM, gelcoating, glue wipe, and installation of a safety platform. After the initial site visit, the company made changes to the glue wipe task that eliminated the need for workers to enter the confined space inside of the wind turbine blade. During the follow-up site visit, 12 personal breathing zone and 8 area air samples were collected from workers performing the modified glue wipe task. During the initial site visit, the geometric means of the personal breathing zone styrene air samples were 1.8 p.p.m. (n = 21) for workers performing the VARTM task, 68 p.p.m. (n = 5) for workers installing a safety platform, and 340 p.p.m. (n = 14) for workers performing the glue wipe task, where n is the number of workers sampled for a given mean result. Gelcoating workers included job categories of millers, gelcoat machine operators, and gelcoaters. Geometric mean personal breathing zone styrene air samples were 150 p.p.m. (n = 6) for millers, 87 p.p.m. (n = 2) for the gelcoat machine operators, and 66 p.p.m. (n = 19) for gelcoaters. The geometric mean of the personal breathing zone styrene air samples from the glue wipe task measured during the follow-up site visit was 31 p.p.m. (n = 12). The closed molding VARTM process was very effective at controlling worker exposures to styrene. Personal breathing zone styrene air samples were reduced by an order of magnitude after changes were made to the glue wipe task. The company used chemical substitution to eliminate styrene exposure during the installation of the safety platform. Recommendations were provided to reduce styrene concentrations during gelcoating.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sterling, D.A.; Roegner, K.C.; Lewis, R.D.
Childhood exposure to lead has been demonstrated to result in health effects and lead-contaminated household dust is a primary exposure source. There is a need to establish reliable methods for sampling surfaces to determine levels of lead contamination. Three vacuums (HVS3, GS80, and MVM) and one wipe method were evaluated for the collection of household floor dust under field sampling conditions within a Superfund site and demographically similar control area. Side-by-side floor samples were taken from three locations within 41 randomly selected households between August and September 1995: a child's bedroom, primary play area, and primary entrance. Analysis was performedmore » to assess the relative collection performance of each sampler, spatial distribution of lead within a household, and correlation of lead loading with observed blood lead level, and to determine if discrete or composites samples were more predictive of blood lead levels. Approximately 90% of the floor surfaces were carpeted. The rank order of sampling methods from greatest to lowest collection efficiency was HVS3 > G80 > wipe > MVM. The HVS3 had the highest level of precision (CV = 0.05), with the GS80 and wipe precisions 0.48 and 0.053, respectively.« less
Hines, Cynthia J; Christianson, Annette L; Jackson, Matthew V; Ye, Xiaoyun; Pretty, Jack R; Arnold, James E; Calafat, Antonia M
2018-06-13
Exposure to bisphenol A (BPA) can be assessed using external and internal exposure measures. We examined the relationship between two measures of external BPA exposure (air and hand-wipe samples) and one of internal exposure (total BPA in urine) for a group of US manufacturing workers. During 2013-2014, we recruited 78 workers from six US companies that made BPA or made products with BPA. We quantified BPA in seven urine samples, two full-shift air samples and in pre- and end-shift hand-wipe samples collected from workers over 2 consecutive days. We examined correlations between creatinine-corrected urinary concentrations of total BPA (total BPACR) and BPA levels in air and hand wipes using Pearson's correlation coefficient. We also applied mixed-effects regression models to examine the relationship between total BPACR with BPA in air (urine~air model) and with BPA in end-shift hand wipes (urine~hand model), separately and together (urine~air+hand model), after adjusting for covariates. End-shift total BPACR strongly correlated with BPA in air (rp = 0.79, P < 0.0001) and nearly as strongly with BPA in end-shift hand wipes (rp = 0.75, P < 0.0001). In mixed-effect models, BPA air concentration and end-shift hand-wipe BPA level were significantly and positively associated with end-shift total BPACR (P < 0.0001 each). We found a significant effect of the Day 1 BPA air concentration on Day 2 total BPACR (P = 0.0104). When BPA air concentration and end-shift hand-wipe BPA level were in the same model, the air concentration (P < 0.0001) was more significant than the hand-wipe level (P = 0.0106). BPA levels in air and end-shift hand wipes strongly correlated with total BPACR, suggesting that both inhalation and dermal contract were likely exposure routes; however, inhalation, on average, appeared to be a more dominant exposure route than dermal contact for these manufacturing workers.
Lessons learned from surface wipe sampling for lead in three workplaces.
Beaucham, Catherine; Ceballos, Diana; King, Bradley
2017-08-01
Surface wipe sampling in the occupational environment is a technique widely used by industrial hygienists. Although several organizations have promulgated standards for sampling lead and other metals, uncertainty still exists when trying to determine an appropriate wipe sampling strategy and how to interpret sampling results. Investigators from the National Institute for Occupational Safety and Health (NIOSH) Health Hazard Evaluation Program have used surface wipe sampling as part of their exposure assessment sampling strategies in a wide range of workplaces. This article discusses wipe sampling for measuring lead on surfaces in three facilities: (1) a battery recycling facility; (2) a firing range and gun store; and (3) an electronic scrap recycling facility. We summarize our findings from the facilities and what we learned by integrating wipe sampling into our sampling plan. Wiping sampling demonstrated lead in non-production surfaces in all three workplaces and that the potential that employees were taking lead home to their families existed. We also found that the presence of metals such as tin can interfere with the colorimetric results. We also discuss the advantages and disadvantages of colorimetric analysis of surface wipe samples and the challenges we faced when interpreting wipe sampling results.
Comparison of sampling methods used for MRSA-classification of herds with breeding pigs.
Broens, E M; Graat, E A M; Engel, B; van Oosterom, R A A; van de Giessen, A W; van der Wolf, P J
2011-01-27
Since the first report on methicillin resistant Staphylococcus aureus (MRSA) CC398 in pigs, several countries have determined the prevalence of MRSA-positive pig herds using different sampling and laboratory techniques. The objective of the study was to compare three sampling methods for MRSA-classification of herds. Therefore, nasal swabs of pigs and environmental wipes were collected from 147 herds with breeding pigs. Per herd, laboratory examination was done on 10 pools of 6 nasal swabs (NASAL), 5 single environmental wipes (ENVSINGLE) and one pool of 5 environmental wipes (ENVPOOL). Large differences in apparent prevalence of MRSA-positive herds between methods were found: 19.1% for ENVPOOL, 53.1% for ENVSINGLE, and 70.8% for NASAL. Pairwise comparisons of methods resulted in relative sensitivities of 26.9% (ENVPOOL vs. NASAL), 34.6% (ENVPOOL vs. ENVSINGLE), and 72.1% (ENVSINGLE vs. NASAL) with relative specificities of respectively 100%, 98.6% and 93.0%. Cohen's kappa was respectively 0.18, 0.32 and 0.55, thus varying between very poor and moderate agreement. Examination of environmental wipes is an easy and non-invasive method to classify herds for MRSA. The number of environmental wipes needed depends on e.g. required detection limits and within-herd prevalence. In low prevalent herds (e.g. herds with <3 positive pools of nasal swabs), 25 single environmental wipes are required to be 90% sure that MRSA is detected at a detection limit similar to analyzing 10 pools of nasal swabs. Individual analysis of environmental wipes is highly recommended, as pooling 5 environmental samples resulted in a substantial reduction of the apparent prevalence. Copyright © 2010 Elsevier B.V. All rights reserved.
Hart, Julie F; Spear, Terry M; Ward, Tony J; Baldwin, Caitlan E; Salo, Marissa N; Elashheb, Mohamed I
2009-01-01
Amphibole asbestos (AA) has been detected on the surface of tree bark in forests neighboring an abandoned vermiculite mine near Libby, Montana. In the present study, simulations were performed to assess potential AA exposure associated with United States Department of Agriculture Forest Service (FS) occupational activities. Bark samples were collected prior, and personal breathing zone (PBZ) and Tyvek clothing wipe samples were collected during and immediately after trials that simulated FS activities. Transmission electron microscopy (TEM) analyses revealed AA bark concentrations up to 15 million structures per square centimeter (s/cm(2)). AA was detected in 25% of the PBZ TEM samples. AA was detected on wipe samples collected from all activities evaluated. This research demonstrates the potential for airborne exposure and transport of AA in the Kootenai National Forest. These findings are especially relevant to those that work in the area and to the general public who may conduct recreational activities.
Comparative Evaluation of Vacuum-based Surface Sampling ...
Journal Article Following a biological contamination incident, collection of surface samples is necessary to determine the extent and level of contamination, and to deem an area safe for reentry upon decontamination. Current sampling strategies targeting Bacillus anthracis spores prescribe vacuum-based methods for rough and/or porous surfaces. In this study, four commonly-used B. anthracis spore sampling devices (vacuum socks, 37 mm 0.8 µm MCE filter cassettes, 37 mm 0.3 µm PTFE filter cassettes, and 3MTM forensic filters) were comparatively evaluated for their ability to recover surface-associated spores. The vacuum sock device was evaluated at two sampling speeds (slow and fast), resulting in five total methods evaluated. Aerosolized spores (~105 cm-2) of a surrogate Bacillus species (Bacillus atrophaeus) were allowed to settle onto three material types (concrete, carpet, and upholstery). Ten replicate samples were collected using each vacuum method, from each of the three material types. In addition, stainless steel (i.e., nonporous) surfaces inoculated simultaneously were sampled with pre-moistened wipes. Recoveries from wipes of steel surfaces were utilized to verify the inoculum, and to normalize vacuum-based recoveries across trials. Recovery (CFU cm-2) and relative recovery (vacuum recovery/wipe recovery) were determined for each method and material type. Relative recoveries were compared by one-way and three-way ANOVA. Data analysis by one-
A "clean-catch" urine sample is performed by collecting the sample of urine in midstream. Men or boys should wipe clean the head ... water and rinse well. A small amount of urine should initially fall into the toilet bowl before ...
Gulson, Brian; Korsch, Michael; Bradshaw, Anthony
2016-01-01
Concerns have been expressed that dust from the minerals processing facilities at Karumba Queensland Australia have resulted in elevated lead (Pb) concentrations in rain water tanks. The ores derived from the Century mine some 304 km from the port. High precision Pb isotopic measurements on environmental samples have been undertaken to evaluate the source of Pb in rainwaters and acid digests from roof wipes and gutter wipes. There does not appear to be any relationship between sample location and the processing facility but samples from the area subject to the prevailing winds show the highest contribution of Century Pb. All gutter wipes (82 to 1270 µg Pb/wipe) have contributions of Century ore ranging from 87% to 96%. The contribution of Century ore to five roof wipes (22 to 88 µg Pb/wipe) ranges from 89% to 97% and in the other two samples there is a mix of Century and Broken Hill Pb. Three of the seven rainwater have contributions of Century ore Pb ranging from 33% to 75%. Two of the other four rainwater samples have the highest water Pb concentrations of 88 and 100 µg/L and their isotopic data show Broken Hill Pb contributions ranging from 77% to 80%. The source of the Broken Hill Pb is probably from the galvanized roofing material and/or brass fittings in the rainwater tanks. The discrimination between various sources is only detectable using high precision 204Pb-based isotopic ratios and not the now common inductively coupled plasma mass spectrometry (ICP-MS ) data presentations of the higher abundance isotopes 208Pb, 207Pb and 206Pb. Isotopic results for the waters demonstrate that apportioning blame where there is an obvious point source may not always be the correct conclusion. Nevertheless the isotopic data for the gutter wipes indicates that there was widespread contamination from the processing facilities throughout the town. PMID:26907319
Gulson, Brian; Korsch, Michael; Bradshaw, Anthony
2016-02-22
Concerns have been expressed that dust from the minerals processing facilities at Karumba Queensland Australia have resulted in elevated lead (Pb) concentrations in rain water tanks. The ores derived from the Century mine some 304 km from the port. High precision Pb isotopic measurements on environmental samples have been undertaken to evaluate the source of Pb in rainwaters and acid digests from roof wipes and gutter wipes. There does not appear to be any relationship between sample location and the processing facility but samples from the area subject to the prevailing winds show the highest contribution of Century Pb. All gutter wipes (82 to 1270 µg Pb/wipe) have contributions of Century ore ranging from 87% to 96%. The contribution of Century ore to five roof wipes (22 to 88 µg Pb/wipe) ranges from 89% to 97% and in the other two samples there is a mix of Century and Broken Hill Pb. Three of the seven rainwater have contributions of Century ore Pb ranging from 33% to 75%. Two of the other four rainwater samples have the highest water Pb concentrations of 88 and 100 µg/L and their isotopic data show Broken Hill Pb contributions ranging from 77% to 80%. The source of the Broken Hill Pb is probably from the galvanized roofing material and/or brass fittings in the rainwater tanks. The discrimination between various sources is only detectable using high precision (204)Pb-based isotopic ratios and not the now common inductively coupled plasma mass spectrometry (ICP-MS ) data presentations of the higher abundance isotopes (208)Pb, (207)Pb and (206)Pb. Isotopic results for the waters demonstrate that apportioning blame where there is an obvious point source may not always be the correct conclusion. Nevertheless the isotopic data for the gutter wipes indicates that there was widespread contamination from the processing facilities throughout the town.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Paik, Samuel Y.; Epperson, Patrick M.; Kasper, Kenneth M.
Here, this article presents air and surface sampling data collected over the first two years since beryllium was introduced as a target material at the National Ignition Facility. Over this time, 101 experiments with beryllium-containing targets were executed. The data provides an assessment of current conditions in the facility and a baseline for future impacts as new, reduced regulatory limits for beryllium are being proposed by both the Occupational Safety and Health Administration and Department of Energy. This study also investigates how beryllium deposits onto exposed surfaces as a result of x-ray vaporization and the effectiveness of simple decontamination measuresmore » in reducing the amount of removable beryllium from a surface. Based on 1,961 surface wipe samples collected from entrant components (equipment directly exposed to target debris) and their surrounding work areas during routine reconfiguration activities, only one result was above the beryllium release limit of 0.2 µg/100 cm 2 and 27 results were above the analytical reporting limit of 0.01 µg/100 cm 2, for a beryllium detection rate of 1.4%. Surface wipe samples collected from the internal walls of the NIF target chamber, however, showed higher levels of beryllium, with beryllium detected on 73% and 87% of the samples during the first and second target chamber entries (performed annually), respectively, with 23% of the samples above the beryllium release limit during the second target chamber entry. The analysis of a target chamber wall panel exposed during the first 30 beryllium-containing experiments (cumulatively) indicated that 87% of the beryllium contamination remains fixed onto the surface after wet wiping the surface and 92% of the non-fixed contamination was removed by decontaminating the surface using a dry wipe followed by a wet wipe. Personal airborne exposures assessed during access to entrant components and during target chamber entry indicated that airborne beryllium was not present in workers' breathing zones. Finally, all the data thus far have shown that beryllium has been effectively managed to prevent exposures to workers during routine and non-routine work.« less
Paik, Samuel Y; Epperson, Patrick M; Kasper, Kenneth M
2017-06-01
This article presents air and surface sampling data collected over the first two years since beryllium was introduced as a target material at the National Ignition Facility. Over this time, 101 experiments with beryllium-containing targets were executed. The data provides an assessment of current conditions in the facility and a baseline for future impacts as new, reduced regulatory limits for beryllium are being proposed by both the Occupational Safety and Health Administration and Department of Energy. This study also investigates how beryllium deposits onto exposed surfaces as a result of x-ray vaporization and the effectiveness of simple decontamination measures in reducing the amount of removable beryllium from a surface. Based on 1,961 surface wipe samples collected from entrant components (equipment directly exposed to target debris) and their surrounding work areas during routine reconfiguration activities, only one result was above the beryllium release limit of 0.2 µg/100 cm 2 and 27 results were above the analytical reporting limit of 0.01 µg/100 cm 2 , for a beryllium detection rate of 1.4%. Surface wipe samples collected from the internal walls of the NIF target chamber, however, showed higher levels of beryllium, with beryllium detected on 73% and 87% of the samples during the first and second target chamber entries (performed annually), respectively, with 23% of the samples above the beryllium release limit during the second target chamber entry. The analysis of a target chamber wall panel exposed during the first 30 beryllium-containing experiments (cumulatively) indicated that 87% of the beryllium contamination remains fixed onto the surface after wet wiping the surface and 92% of the non-fixed contamination was removed by decontaminating the surface using a dry wipe followed by a wet wipe. Personal airborne exposures assessed during access to entrant components and during target chamber entry indicated that airborne beryllium was not present in workers' breathing zones. All the data thus far have shown that beryllium has been effectively managed to prevent exposures to workers during routine and non-routine work.
Paik, Samuel Y.; Epperson, Patrick M.; Kasper, Kenneth M.
2017-02-28
Here, this article presents air and surface sampling data collected over the first two years since beryllium was introduced as a target material at the National Ignition Facility. Over this time, 101 experiments with beryllium-containing targets were executed. The data provides an assessment of current conditions in the facility and a baseline for future impacts as new, reduced regulatory limits for beryllium are being proposed by both the Occupational Safety and Health Administration and Department of Energy. This study also investigates how beryllium deposits onto exposed surfaces as a result of x-ray vaporization and the effectiveness of simple decontamination measuresmore » in reducing the amount of removable beryllium from a surface. Based on 1,961 surface wipe samples collected from entrant components (equipment directly exposed to target debris) and their surrounding work areas during routine reconfiguration activities, only one result was above the beryllium release limit of 0.2 µg/100 cm 2 and 27 results were above the analytical reporting limit of 0.01 µg/100 cm 2, for a beryllium detection rate of 1.4%. Surface wipe samples collected from the internal walls of the NIF target chamber, however, showed higher levels of beryllium, with beryllium detected on 73% and 87% of the samples during the first and second target chamber entries (performed annually), respectively, with 23% of the samples above the beryllium release limit during the second target chamber entry. The analysis of a target chamber wall panel exposed during the first 30 beryllium-containing experiments (cumulatively) indicated that 87% of the beryllium contamination remains fixed onto the surface after wet wiping the surface and 92% of the non-fixed contamination was removed by decontaminating the surface using a dry wipe followed by a wet wipe. Personal airborne exposures assessed during access to entrant components and during target chamber entry indicated that airborne beryllium was not present in workers' breathing zones. Finally, all the data thus far have shown that beryllium has been effectively managed to prevent exposures to workers during routine and non-routine work.« less
Utility of snout wipe samples for influenza A virus surveillance in exhibition swine populations
Edwards, Jody L; Nelson, Sarah W; Workman, Jeffrey D; Slemons, Richard D; Szablewski, Christine M; Nolting, Jacqueline M; Bowman, Andrew S
2014-01-01
Background Sporadic influenza A virus (IAV) outbreaks in humans and swine have resulted from commingling of large numbers of people and pigs at agricultural fairs in the United States. Current antemortem IAV surveillance strategies in swine require collecting nasal swabs, which entails restraining pigs with snares. Restraint is labor-intensive for samplers, stressful for pigs, and displeasing to onlookers because pigs often resist and vocalize. Objective To evaluate the utility of snout wipes in exhibition swine as a method to make IAV surveillance efforts less intrusive, less labor-intensive, and more widely accepted among pig owners and exhibition officials. Methods Three materials (rayon/polyester gauze, cotton gauze, and Swiffer® Sweeper dry cloths) were inoculated with IAV, and viral recoveries from these materials were quantified using qRT-PCR and TCID50 assays. In a field trial, paired cotton gauze snout wipes and gold standard polyester-tipped nasal swabs were collected from 553 pigs representing 29 agricultural fairs and the qualitative results of rRT-PCR and viral isolation were compared. Results and Conclusions Viral recoveries from potential snout wipe materials ranged from 0·26 to 1·59 log10 TCID50/ml less than that of the positive control in which no substrate was included; rayon/polyester gauze performed significantly worse than the other materials. In the field, snout wipes and nasal swabs had high levels of agreement for both rRT-PCR detection and virus isolation. Although further investigation and refinement of the sampling method is needed, results indicate that snout wipes will facilitate convenient and undisruptive IAV surveillance in pigs at agricultural fairs. PMID:25043408
Comparison of Wipe Materials and Wetting Agents for Pesticide Residue Collection from Hard Surfaces
Different wipe materials and wetting agents have been used to collect pesticide residues from surfaces, but little is known about their comparability. To inform the selection of a wipe for the National Children's Study, the analytical feasibility, collection efficiency, and preci...
2008 Homeland Security S and T Stakeholders Conference West volume 2 Monday
2008-01-16
per collection and pressure to be applied, etc. . - Enviromental effects; dry vs. wet surface (vs. type of sample swipe), clean vs. dirty surfaces...selection of collection via low volume or high volume sampling, distance to suspect item critical, etc. - Enviromental effects; temperature (range of...selection of material, collection via hand wiping or sampling wand, area per collection and pressure to be applied, etc. . - Enviromental effects; dry
Sterling, D A; Lewis, R D; Luke, D A; Shadel, B N
2000-06-01
Dust wipe samples collected in the field were tested by nondestructive X-ray fluorescence (XRF) followed by laboratory analysis with flame atomic absorption spectrophotometry (FAAS). Data were analyzed for precision and accuracy of measurement. Replicate samples with the XRF show high precision with an intraclass correlation coefficient (ICC) of 0.97 (P<0.0001) and an overall coefficient of variation of 11.6%. Paired comparison indicates no statistical difference (P=0.272) between XRF and FAAS analysis. Paired samples are highly correlated with an R(2) ranging between 0.89 for samples that contain paint chips and 0.93 for samples that do not contain paint chips. The ICC for absolute agreement between XRF and laboratory results was 0.95 (P<0.0001). The relative error over the concentration range of 25 to 14,200 microgram Pb is -12% (95% CI, -18 to -5). The XRF appears to be an excellent method for rapid on-site evaluation of dust wipes for clearance and risk assessment purposes, although there are indications of some confounding when paint chips are present. Copyright 2000 Academic Press.
Siani, Harsha; Wesgate, Rebecca; Maillard, Jean-Yves
2018-05-11
Antimicrobial wipes are increasingly used in health care settings. This study evaluates, in a clinical setting, the efficacy of sporicidal wipes versus a cloth soaked in a 1,000 ppm chlorine solution. A double-crossover study was performed on 2 different surgical and cardiovascular wards in a 1,000-bed teaching hospital over 29 weeks. The intervention period that consisted of surface decontamination with the preimpregnated wipe or cloth soaked in chlorine followed a 5-week baseline assessment of microbial bioburden on surfaces. Environmental samples from 11 surfaces were analyzed weekly for their microbial content. A total of 1,566 environmental samples and 1,591 ATP swabs were analyzed during the trial. Overall, there were significant differences in the recovery of total aerobic bacteria (P < .001), total anaerobic bacteria (P < .001), and ATP measurement (P < .001) between wards and between the different parts of the crossover study. Generally, the use of wipes produced the largest reduction in the total aerobic and anaerobic counts when compared with the baseline data or the use of 1,000 ppm chlorine. Collectively, the introduction of training plus daily wipe disinfection significantly reduced multidrug-resistant organisms recovered from surfaces. Reversion to using 1,000 ppm chlorine resulted in the number of sites positive for multidrug-resistant organisms rising again. This double-crossover study is the first controlled field trial comparison of using preimpregnated wipes versus cotton cloth dipped into a bucket of hypochlorite to decrease surface microbial bioburden. The results demonstrate the superiority of the preimpregnated wipes in significantly decreasing microbial bioburden from high-touch surfaces. Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
Wipe sampling is an important technique for the estimation of contaminant deposition in buildings, homes, or outdoor surfaces as a source of possible human exposure. Numerous
methods of wipe sampling exist, and each method has its own specification for the type of wipe, we...
40 CFR 761.250 - Sample site selection for pipeline section abandonment.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Sample site selection for pipeline... Disposal of Natural Gas Pipeline: Selecting Sample Sites, Collecting Surface Samples, and Analyzing Standard PCB Wipe Samples § 761.250 Sample site selection for pipeline section abandonment. This procedure...
40 CFR 761.250 - Sample site selection for pipeline section abandonment.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 31 2011-07-01 2011-07-01 false Sample site selection for pipeline... Disposal of Natural Gas Pipeline: Selecting Sample Sites, Collecting Surface Samples, and Analyzing Standard PCB Wipe Samples § 761.250 Sample site selection for pipeline section abandonment. This procedure...
Cavana, Paola; Peano, Andrea; Petit, Jean-Yanique; Tizzani, Paolo; Perrot, Sébastien; Bensignor, Emmanuel; Guillot, Jacques
2015-08-01
Wipes containing chlorhexidine and azole derivates have been recommended for veterinary use. No study has been published about their activity against Malassezia pachydermatis. To evaluate the in vivo and in vitro activity of wipes soaked in a chlorhexidine, climbazole and Tris-EDTA solution against Malassezia pachydermatis. Five research colony shar-pei dogs. Wipes were applied once daily onto the left axilla, left groin and perianal area (protocol A), and twice daily on the right axilla, right groin and umbilical region (protocol B) for 3 days. In vivo activity was evaluated by quantifying Malassezia colonies through contact plates on the selected body areas before and after wipe application. The activity of the solution in which the wipes were soaked was assessed in vitro by contact tests following the European Standard UNI EN 1275 guidelines. Samples collected after wipe application showed a significant and rapid reduction of Malassezia yeast CFU. No significant difference in the Malassezia reduction was found between protocols A and B. In vitro assay showed 100% activity against Malassezia yeasts after a 15 min contact time with the wipe solution. Wipes containing chlorhexidine, climbazole and Tris-EDTA substantially reduced the M. pachydermatis population on the skin of dogs. The results, although this was an uncontrolled study performed on a small number of dogs, suggest that these wipes may be useful for topical therapy of Malassezia dermatitis involving the lips, paws, perianal area and skin folds. © 2015 ESVD and ACVD.
Miyake, Tomohiro; Iwamoto, Takuya; Tanimura, Manabu; Okuda, Masahiro
2013-12-01
In spite of current recommended safe handling procedures, the potential for the exposure of healthcare providers to hazardous drugs exists in the workplace. A reliance on biological safety cabinets to provide total protection against the exposure to hazardous drugs is insufficient. Preventing workplace contamination is the best strategy to minimize cytotoxic drug exposure in healthcare providers. This study was conducted to compare surface contamination and personnel exposure to cyclophosphamide before and after the implementation of a closed-system drug transfer device, PhaSeal, under the influence of cleaning according to the Japanese guidelines. Personnel exposure was evaluated by collecting 24 h urine samples from 4 pharmacists. Surface contamination was assessed by the wiping test. Four of 6 wipe samples collected before PhaSeal indicated a detectable level of cyclophosphamide. About 7 months after the initiation of PhaSeal, only one of 6 wipe samples indicated a detectable level of cyclophosphamide. Although all 4 employees who provided urine samples had positive results for the urinary excretion of cyclophosphamide before PhaSeal, these levels returned to minimal levels in 2 pharmacists after PhaSeal. In combination with the biological safety cabinet and cleaning according to the Japanese guidelines, PhaSeal further reduces surface contamination and healthcare providers exposure to cyclophosphamide to almost undetectable levels.
Quintana, Penelope J E; Matt, Georg E; Chatfield, Dale; Zakarian, Joy M; Fortmann, Addie L; Hoh, Eunha
2013-09-01
Secondhand smoke contains a mixture of pollutants that can persist in air, dust, and on surfaces for months or longer. This persistent residue is known as thirdhand smoke (THS). Here, we detail a simple method of wipe sampling for nicotine as a marker of accumulated THS on surfaces. We analyzed findings from 5 real-world studies to investigate the performance of wipe sampling for nicotine on surfaces in homes, cars, and hotels in relation to smoking behavior and smoking restrictions. The intraclass correlation coefficient for side-by-side samples was 0.91 (95% CI: 0.87-0.94). Wipe sampling for nicotine reliably distinguished between private homes, private cars, rental cars, and hotels with and without smoking bans and was significantly positively correlated with other measures of tobacco smoke contamination such as air and dust nicotine. The sensitivity and specificity of possible threshold values (0.1, 1, and 10 μg/m(2)) were evaluated for distinguishing between nonsmoking and smoking environments. Sensitivity was highest at a threshold of 0.1 μg/m(2), with 74%-100% of smoker environments showing nicotine levels above threshold. Specificity was highest at a threshold of 10 μg/m(2), with 81%-100% of nonsmoker environments showing nicotine levels below threshold. The optimal threshold will depend on the desired balance of sensitivity and specificity and on the types of smoking and nonsmoking environments. Surface wipe sampling for nicotine is a reliable, valid, and relatively simple collection method to quantify THS contamination on surfaces across a wide range of field settings and to distinguish between nonsmoking and smoking environments.
40 CFR 761.253 - Chemical analysis.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Chemical analysis. 761.253 Section 761.253 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT... Sample Sites, Collecting Surface Samples, and Analyzing Standard PCB Wipe Samples § 761.253 Chemical...
40 CFR 761.253 - Chemical analysis.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 31 2011-07-01 2011-07-01 false Chemical analysis. 761.253 Section 761.253 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT... Sample Sites, Collecting Surface Samples, and Analyzing Standard PCB Wipe Samples § 761.253 Chemical...
40 CFR 761.253 - Chemical analysis.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 31 2014-07-01 2014-07-01 false Chemical analysis. 761.253 Section 761.253 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT... Sample Sites, Collecting Surface Samples, and Analyzing Standard PCB Wipe Samples § 761.253 Chemical...
40 CFR 761.253 - Chemical analysis.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 32 2013-07-01 2013-07-01 false Chemical analysis. 761.253 Section 761.253 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT... Sample Sites, Collecting Surface Samples, and Analyzing Standard PCB Wipe Samples § 761.253 Chemical...
40 CFR 761.253 - Chemical analysis.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 32 2012-07-01 2012-07-01 false Chemical analysis. 761.253 Section 761.253 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT... Sample Sites, Collecting Surface Samples, and Analyzing Standard PCB Wipe Samples § 761.253 Chemical...
40 CFR 761.257 - Determining the regulatory status of sampled pipe.
Code of Federal Regulations, 2010 CFR
2010-07-01
... COMMERCE, AND USE PROHIBITIONS Determining a PCB Concentration for Purposes of Abandonment or Disposal of Natural Gas Pipeline: Selecting Sample Sites, Collecting Surface Samples, and Analyzing Standard PCB Wipe... disposal of a pipe segment that has been sampled, the sample results for that segment determines its PCB...
Connor, Thomas H; Smith, Jerome P
2016-09-01
At the present time, the method of choice to determine surface contamination of the workplace with antineoplastic and other hazardous drugs is surface wipe sampling and subsequent sample analysis with a variety of analytical techniques. The purpose of this article is to review current methodology for determining the level of surface contamination with hazardous drugs in healthcare settings and to discuss recent advances in this area. In addition it will provide some guidance for conducting surface wipe sampling and sample analysis for these drugs in healthcare settings. Published studies on the use of wipe sampling to measure hazardous drugs on surfaces in healthcare settings drugs were reviewed. These studies include the use of well-documented chromatographic techniques for sample analysis in addition to newly evolving technology that provides rapid analysis of specific antineoplastic. Methodology for the analysis of surface wipe samples for hazardous drugs are reviewed, including the purposes, technical factors, sampling strategy, materials required, and limitations. The use of lateral flow immunoassay (LFIA) and fluorescence covalent microbead immunosorbent assay (FCMIA) for surface wipe sample evaluation is also discussed. Current recommendations are that all healthc a re settings where antineoplastic and other hazardous drugs are handled include surface wipe sampling as part of a comprehensive hazardous drug-safe handling program. Surface wipe sampling may be used as a method to characterize potential occupational dermal exposure risk and to evaluate the effectiveness of implemented controls and the overall safety program. New technology, although currently limited in scope, may make wipe sampling for hazardous drugs more routine, less costly, and provide a shorter response time than classical analytical techniques now in use.
40 CFR 761.240 - Scope and definitions.
Code of Federal Regulations, 2014 CFR
2014-07-01
...: Selecting Sample Sites, Collecting Surface Samples, and Analyzing Standard PCB Wipe Samples § 761.240 Scope and definitions. (a) Use these procedures to select surface sampling sites for natural gas pipe to determine its PCB surface concentration for abandonment-in-place or removal and disposal off-site in...
40 CFR 761.240 - Scope and definitions.
Code of Federal Regulations, 2011 CFR
2011-07-01
...: Selecting Sample Sites, Collecting Surface Samples, and Analyzing Standard PCB Wipe Samples § 761.240 Scope and definitions. (a) Use these procedures to select surface sampling sites for natural gas pipe to determine its PCB surface concentration for abandonment-in-place or removal and disposal off-site in...
40 CFR 761.240 - Scope and definitions.
Code of Federal Regulations, 2012 CFR
2012-07-01
...: Selecting Sample Sites, Collecting Surface Samples, and Analyzing Standard PCB Wipe Samples § 761.240 Scope and definitions. (a) Use these procedures to select surface sampling sites for natural gas pipe to determine its PCB surface concentration for abandonment-in-place or removal and disposal off-site in...
40 CFR 761.240 - Scope and definitions.
Code of Federal Regulations, 2013 CFR
2013-07-01
...: Selecting Sample Sites, Collecting Surface Samples, and Analyzing Standard PCB Wipe Samples § 761.240 Scope and definitions. (a) Use these procedures to select surface sampling sites for natural gas pipe to determine its PCB surface concentration for abandonment-in-place or removal and disposal off-site in...
Forbes, Thomas P; Sisco, Edward; Staymates, Matthew
2018-05-07
Infrared thermal desorption (IRTD) was coupled with direct analysis in real time mass spectrometry (DART-MS) for the detection of both inorganic and organic explosives from wipe collected samples. This platform generated discrete and rapid heating rates that allowed volatile and semivolatile organic explosives to thermally desorb at relatively lower temperatures, while still achieving elevated temperatures required to desorb nonvolatile inorganic oxidizer-based explosives. IRTD-DART-MS demonstrated the thermal desorption and detection of refractory potassium chlorate and potassium perchlorate oxidizers, compounds difficult to desorb with traditional moderate-temperature resistance-based thermal desorbers. Nanogram to sub-nanogram sensitivities were established for analysis of a range of organic and inorganic oxidizer-based explosive compounds, with further enhancement limited by the thermal properties of the most common commercial wipe materials. Detailed investigations and high-speed visualization revealed conduction from the heated glass-mica base plate as the dominant process for heating of the wipe and analyte materials, resulting in thermal desorption through boiling, aerosolization, and vaporization of samples. The thermal desorption and ionization characteristics of the IRTD-DART technique resulted in optimal sensitivity for the formation of nitrate adducts with both organic and inorganic species. The IRTD-DART-MS coupling and IRTD in general offer promising explosive detection capabilities to the defense, security, and law enforcement arenas.
Galea, Karen S; Mueller, Will; Arfaj, Ayman M; Llamas, Jose L; Buick, Jennifer; Todd, David; McGonagle, Carolyn
2018-05-21
Crude oil may cause adverse dermal effects therefore dermal exposure is an exposure route of concern. Galea et al. (2014b) reported on a study comparing recovery (wipe) and interception (cotton glove) dermal sampling methods. The authors concluded that both methods were suitable for assessing dermal exposure to oil-based drilling fluids and crude oil but that glove samplers may overestimate the amount of fluid transferred to the skin. We describe a study which aimed to further evaluate the wipe sampling method to assess dermal exposure to crude oil, with this assessment including extended sample storage periods and sampling efficiency tests being undertaken at environmental conditions to mimic those typical of outdoor conditions in Saudi Arabia. The wipe sampling method was then used to assess the laboratory technicians' actual exposure to crude oil during typical petroleum laboratory tasks. Overall, acceptable storage efficiencies up to 54 days were reported with results suggesting storage stability over time. Sampling efficiencies were also reported to be satisfactory at both ambient and elevated temperature and relative humidity environmental conditions for surrogate skin spiked with known masses of crude oil and left up to 4 h prior to wiping, though there was an indication of reduced sampling efficiency over time. Nineteen petroleum laboratory technicians provided a total of 35 pre- and 35 post-activity paired hand wipe samples. Ninety-three percent of the pre-exposure paired hand wipes were less than the analytical limit of detection (LOD), whereas 46% of the post-activity paired hand wipes were less than the LOD. The geometric mean paired post-activity wipe sample measurement was 3.09 µg cm-2 (range 1.76-35.4 µg cm-2). It was considered that dermal exposure most frequently occurred through direct contact with the crude oil (emission) or via deposition. The findings of this study suggest that the wipe sampling method is satisfactory in quantifying laboratory technicians' dermal exposure to crude oil. It is therefore considered that this wipe sampling method may be suitable to quantify dermal exposure to crude oil for other petroleum workers.
Sampling scheme for pyrethroids on multiple surfaces on commercial aircrafts.
Mohan, Krishnan R; Weisel, Clifford P
2010-06-01
A wipe sampler for the collection of permethrin from soft and hard surfaces has been developed for use in aircraft. "Disinsection" or application of pesticides, predominantly pyrethrods, inside commercial aircraft is routinely required by some countries and is done on an as-needed basis by airlines resulting in potential pesticide dermal and inhalation exposures to the crew and passengers. A wipe method using filter paper and water was evaluated for both soft and hard aircraft surfaces. Permethrin was analyzed by GC/MS after its ultrasonication extraction from the sampling medium into hexane and volume reduction. Recoveries, based on spraying known levels of permethrin, were 80-100% from table trays, seat handles and rugs; and 40-50% from seat cushions. The wipe sampler is easy to use, requires minimum training, is compatible with the regulations on what can be brought through security for use on commercial aircraft, and readily adaptable for use in residential and other settings.
40 CFR 761.247 - Sample site selection for pipe segment removal.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Natural Gas Pipeline: Selecting Sample Sites, Collecting Surface Samples, and Analyzing Standard PCB Wipe Samples § 761.247 Sample site selection for pipe segment removal. (a) General. (1) Select the pipe... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Sample site selection for pipe segment...
40 CFR 761.247 - Sample site selection for pipe segment removal.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 31 2011-07-01 2011-07-01 false Sample site selection for pipe segment... Natural Gas Pipeline: Selecting Sample Sites, Collecting Surface Samples, and Analyzing Standard PCB Wipe Samples § 761.247 Sample site selection for pipe segment removal. (a) General. (1) Select the pipe...
Wille, Sarah M R; Di Fazio, Vincent; Toennes, Stefan W; van Wel, Janelle H P; Ramaekers, Johannes G; Samyn, Nele
2015-03-01
Oral fluid (OF) is potentially useful to detect driving under the influence of drugs because of its ease of sampling. While cannabis is the most prevalent drug in Europe, sensitivity issues for Δ(9) -tetrahydrocannabinol (THC) screening and problems during OF collection are observed. The ability of a recently improved OF screening device - the DrugWipe5S(®) , to detect recent THC use in chronic cannabis smokers, was studied. Ten subjects participated in a double-blind placebo-controlled study. The subjects smoked two subsequent doses of THC; 300 µg/kg and 150 µg/kg with a pause of 75 min using a Volcano vapourizer. DrugWipe5S(®) screening and OF collection using the Quantisal™ device were performed at baseline, 5 min after each administration and 80 min after the last inhalation. Blood samples were drawn simultaneously. The screening devices (n = 80) were evaluated visually after 8 min, while the corresponding OF and serum samples were analyzed respectively with ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) or gas chromatography-mass spectrometry (GC-MS). Neat OF THC concentrations ranged from 12 361 ng/g 5 min after smoking down to 34 ng/g 80 min later. Under placebo conditions, a median THC concentration of 8 ng/g OF (0-746 ng/g) and < 1 ng/ mL serum (0-7.8 ng/mL) was observed. The DrugWipe5S(®) was positive just after smoking (90%); however, sensitivity rapidly decreased within 1.5 h (50%). Sensitivity of DrugWipe5S(®) should be improved. As chronic cannabis users have high residual THC concentrations in their serum and OF, confirmation cut-offs should be set according to the aim of detecting recent drug use or establishing zero tolerance. Copyright © 2014 John Wiley & Sons, Ltd.
As the Human Exposure Program focuses on the exposure of children to pesticides, there are concerns about the effect, or perceived effect, of components of the sampling procedure on the health and well-being of the infant and the ability to collect pesticide residues.
One...
40 CFR 761.240 - Scope and definitions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... PROHIBITIONS Determining a PCB Concentration for Purposes of Abandonment or Disposal of Natural Gas Pipeline: Selecting Sample Sites, Collecting Surface Samples, and Analyzing Standard PCB Wipe Samples § 761.240 Scope... determine its PCB surface concentration for abandonment-in-place or removal and disposal off-site in...
RELATIONSHIPS OF METALS IN FLOOR DUST AND ON THE HANDS OF TODDLERS
Toddlers are characterized by their frequent hand-to-mouth activity and exploratory behavior. This puts them at risk for exposure to environmental contaminants. Wipe samples are traditionally used to collect dust samples in homes. The assumption is that dust samples are indicativ...
Genital region cleansing wipes: Effects on urine culture contamination.
Selek, Mehmet Burak; Bektöre, Bayhan; Sezer, Ogün; Kula Atik, Tuğba; Baylan, Orhan; Özyurt, Mustafa
2017-01-30
Urine culture is the gold standard test for revealing the microbial agent causing urinary tract infection (UTI). Culture results are affected by sampling techniques; improper sampling leads to contamination of urine and thus contamination of the culture with urogenital flora. We aimed to evaluate the effect of urogenital cleansing, performed with chlorhexidine-containing genital region cleansing wipes (GRCW) on contamination rates. A total of 2,665 patients with UTI-related complaints and with urine culture requests from various outpatient clinics were enrolled in the study. Of the patients, 1,609 in the experimental group used GRCW before sampling, while 1,046 in the control group did not use any wipes. The contamination rate in the experimental group patients was 7.7%, while it was 15.8% in the control group. Contamination rates were significantly higher in the control group than in the experimental group for both women and men. Contamination rates for children and adults were also significantly lower in the experimental group than in the control group. Our study, conducted in a large population, showed that the use of chlorhexidine-containing cleansing wipes significantly reduced urine culture contamination rates in both genders, in both child and adult age groups. Using GRCW, collection of urine after urogenital area cleansing will decrease the contamination problem.
Surface wipe sampling is a frequently used technique for measuring persistent pollutants in residential environments. One characteristic of this form of sampling is the need to extract the entire wipe sample to achieve adequate sensitivity and to ensure representativeness. Most s...
NASA Astrophysics Data System (ADS)
Chen, F.; La Duc, M. T.; Baker, A.; Koukol, R.; Barengoltz, J.; Kern, R.; Venkateswaran, K.
2001-12-01
Europa has attracted much attention as evidence suggests the presence of a liquid ocean beneath this Jupiter moon's frozen crust. Such an environment might be conducive to the origins of life. Since robotic exploration of Europa is being planned, it becomes crucial to prepare for bio-burden reduction of hardware assembled for Europa missions to avoid contamination of Europa's pristine environment. In this study, we examined the microbial diversity of samples collected from two flight-ready circuit boards and their assembly facility. Also, because Jupiter's strong radiation environment may be able to reduce the viable microbial contamination on flight components, we have also studied the effects of radiation on microbial communities found to be associated with the space-flight hardware and/or present in the assembly facility. Surface samples thought to be representative of considerable human contact were collected from two circuit boards and various locations within the assembly facility using polyester swabs (swab samples). Likewise, sterile wipes were used to sample a shelf above the workstation where the circuit boards were assembled and the floor of the facility (wipe samples). The swab and wipe samples were pooled separately and divided into two halves, one of which was irradiated with 1Mrad gamma radiation for 5.5 hours, the other was not irradiated. About 1.2x104 and 6x104 CFUs/m2 cultivable microbes were detected in the swab and wipe samples, respectively. Radiation proved effective in inhibiting the growth of most microbes. Further characterization of the bacterial colonies observed in the irradiated swab and wipe samples is necessary to determine the degree of the radiation resistance. The16S rDNA sequence analysis of the cultivable microbes indicated that the assembly facility consists mostly of the members of actinobacteria, corynebacteria and pseudomonads. However, the swab samples that include the circuit boards were predominantly populated with Bacillus and Staphylococcus. Molecular microbial diversity was also studied by cloning the 16S rDNA PCR fragment from the samples. The non-irradiated swab samples were largely populated by species of Exiguobacter and Bacillus whereas the irradiated swab samples were dominated by Bacillus and E. coli. Radiation damage of microorganisms was also investigated by epifluorescence microscopy. In summary, our study has shown that gamma radiation can inhibit the growth of most of the cultivable microbes, but preliminary results suggest that radiation such as this has little adverse effect on the DNA molecules of these microorganisms.
Ďurč, Pavol; Foret, František; Pokojová, Eva; Homola, Lukáš; Skřičková, Jana; Herout, Vladimír; Dastych, Milan; Vinohradská, Hana; Kubáň, Petr
2017-05-01
A new approach for sweat analysis used in cystic fibrosis (CF) diagnosis is proposed. It consists of a noninvasive skin-wipe sampling followed by analysis of target ions using capillary electrophoresis with contactless conductometric detection (C4D). The skin-wipe sampling consists of wiping a defined skin area with precleaned cotton swab moistened with 100 μL deionized water. The skin-wipe sample is then extracted for 3 min into 400 μL deionized water, and the extract is analyzed directly. The developed sampling method is cheap, simple, fast, and painless, and can replace the conventional pilocarpine-induced sweat chloride test commonly applied in CF diagnosis. The aqueous extract of the skin-wipe sample content is analyzed simultaneously by capillary electrophoresis with contactless conductometric detection using a double opposite end injection. A 20 mmol/L L-histidine/2-(N-morpholino)ethanesulfonic acid and 2 mmol/L 18-crown-6 at pH 6 electrolyte can separate all the major ions in less than 7 min. Skin-wipe sample extracts from 30 study participants-ten adult patients with CF (25-50 years old), ten pediatric patients with CF (1-15 years old), and ten healthy control individuals (1-18 years old)-were obtained and analyzed. From the analyzed ions in all samples, a significant difference between chloride and potassium concentrations was found in the CF patients and healthy controls. We propose the use of the Cl - /K + ratio rather than the absolute Cl - concentration and a cutoff value of 4 in skin-wipe sample extracts as an alternative to the conventional sweat chloride analysis. The proposed Cl - /K + ion ratio proved to be a more reliable indicator, is independent of the patient's age, and allows better differentiation between non-CF individuals and CF patients having intermediate values on the Cl - sweat test. Figure New approach for cystic fibrosis diagnosis based on skin-wipe sampling of forearm and analysis of ionic content (Cl - /K + ratio) in skin-wipe extracts by capillary electrophoresis with contactless conductometric detection.
Sampling scheme for pyrethroids on multiple surfaces on commercial aircrafts
MOHAN, KRISHNAN R.; WEISEL, CLIFFORD P.
2015-01-01
A wipe sampler for the collection of permethrin from soft and hard surfaces has been developed for use in aircraft. “Disinsection” or application of pesticides, predominantly pyrethrods, inside commercial aircraft is routinely required by some countries and is done on an as-needed basis by airlines resulting in potential pesticide dermal and inhalation exposures to the crew and passengers. A wipe method using filter paper and water was evaluated for both soft and hard aircraft surfaces. Permethrin was analyzed by GC/MS after its ultrasonication extraction from the sampling medium into hexane and volume reduction. Recoveries, based on spraying known levels of permethrin, were 80–100% from table trays, seat handles and rugs; and 40–50% from seat cushions. The wipe sampler is easy to use, requires minimum training, is compatible with the regulations on what can be brought through security for use on commercial aircraft, and readily adaptable for use in residential and other settings. PMID:19756041
The method for extracting and preparing a dermal or surface wipe sample for analysis of acidic persistent organic pollutants is summarized in this standard operating procedure. It covers the extraction and concentration of samples that are to be analyzed by gas chromatography/mas...
The purpose of this SOP is to describe the procedures for extracting and preparing a sill surface wipe sample for gas chromatography/mass spectrometry (GC/MS) analysis of pesticides. This procedure is also used for the pre-shipment analysis of sill wipe samples for materials sui...
Chemicals are dispersed by numerous accidental, deliberate, or weather-related events. Often, rapid analyses are desired to identify dispersed chemicals and to delineate areas of contamination. Hundreds of wipe samples might be collected from outdoor surfaces or building interi...
Forbes, Thomas P; Staymates, Matthew; Sisco, Edward
2017-08-07
Wipe collected analytes were thermally desorbed using broad spectrum near infrared heating for mass spectrometric detection. Employing a twin tube filament-based infrared emitter, rapid and efficiently powered thermal desorption and detection of nanogram levels of explosives and narcotics was demonstrated. The infrared thermal desorption (IRTD) platform developed here used multi-mode heating (direct radiation and secondary conduction from substrate and subsequent convection from air) and a temperature ramp to efficiently desorb analytes with vapor pressures across eight orders of magnitude. The wipe substrate experienced heating rates up to (85 ± 2) °C s -1 with a time constant of (3.9 ± 0.2) s for 100% power emission. The detection of trace analytes was also demonstrated from complex mixtures, including plastic-bonded explosives and exogenous narcotics, explosives, and metabolites from collected artificial latent fingerprints. Manipulation of the emission power and duration directly controlled the heating rate and maximum temperature, enabling differential thermal desorption and a level of upstream separation for enhanced specificity. Transitioning from 100% power and 5 s emission duration to 25% power and 30 s emission enabled an order of magnitude increase in the temporal separation (single seconds to tens of seconds) of the desorption of volatile and semi-volatile species within a collected fingerprint. This mode of operation reduced local gas-phase concentrations, reducing matrix effects experienced with high concentration mixtures. IRTD provides a unique platform for the desorption of trace analytes from wipe collections, an area of importance to the security sector, transportation agencies, and customs and border protection.
Van Nimmen, Nadine F J; Veulemans, Hendrik A F
2004-05-07
A highly sensitive gas chromatographic-mass spectrometric (GC-MS) analytical method for the determination of the opioid narcotics fentanyl, alfentanil, and sufentanil in industrial hygiene personal air samples and surface contamination wipes was developed and comprehensively validated. Sample preparation involved a single step extraction of the samples with methanol, fortified with a fixed amount of the penta-deuterated analogues of the opioid narcotics as internal standard. The GC-MS analytical procedure using selected ion monitoring (SIM) was shown to be highly selective. Linearity was shown for levels of extracted wipe and air samples corresponding to at least 0.1-2 times their surface contamination limit (SCL) and accordingly to 0.1-2 times their time weighted average occupational exposure limit (OEL-TWA) based on a full shift 9601 air sample. Extraction recoveries were determined for spiked air samples and surface wipes and were found to be quantitative for both sampling media in the entire range studied. The air sampling method's limit of detection (LOD) was determined to be 0.4 ng per sample for fentanyl and sufentanil and 1.6 ng per sample for alfentanil, corresponding to less than 1% of their individual OEL for a full shift air sample (9601). The limit of quantification (LOQ) was found to be 1.4, 1.2, and 5.0 ng per filter for fentanyl, sufentanil, and alfentanil, respectively. The wipe sampling method had LODs of 4 ng per wipe for fentanyl and sufentanil and 16 ng per wipe for alfentanil and LOQs of respectively, 14, 12, and 50 ng per wipe. The analytical intra-assay precision of the air sampling and wipe sampling method, defined as the coefficient of variation on the analytical result of six replicate spiked media was below 10 and 5%, respectively, for all opioids at all spike levels. Accuracy expressed as relative error was determined to be below 10%, except for alfentanil at the lowest spike level (-13.1%). The stability of the opioids during simulated air sampling was investigated. For fentanyl and sufentanil a quantitative recovery was observed at all spike levels, while for alfentanil recoveries ranged from 60.3 to 85.4%. When spiked air samples were stored at ambient temperature and at -15 degrees C quantitative recovery was found for fentanyl and sufentanil after 7 and 14 days. For alfentanil a slight loss seemed to occur upon storage during 7 days, being more explicit after 14 days. Ambient storage of spiked wipes seemed to lead to significant losses of all opioids studied, yielding recoveries of 37.7-88.3%. Upon storage of similar wipes at -15 degrees C a significantly higher recovery was found ranging from 77.3 to 88.3%. The developed analytical and sampling procedures have been recently applied in an explorative field study of which the results of surface contamination wipe sampling are presented in this paper. To our knowledge, this is the first study addressing the development and validation of analytical procedures for the assessment of external occupational exposure to potent opioid narcotics.
Bartel, Sylvia B; Tyler, Timothy G; Power, Luci A
2018-02-15
Results of a study to evaluate the effectiveness of a recently introduced closed system drug-transfer device (CSTD) in reducing surface contamination during compounding and simulated administration of antineoplastic hazardous drugs (AHDs) are reported. Wipe samples were collected from 6 predetermined surfaces in compounding and infusion areas of 13 U.S. cancer centers to establish preexisting levels of surface contamination by 2 marker AHDs (cyclophosphamide and fluorouracil). Stainless steel templates were placed over the 6 previously sampled surfaces, and the marker drugs were compounded and infused per a specific protocol using all components of the CSTD. Wipe samples were collected from the templates after completion of tasks and analyzed for both marker AHDs. Aggregated results of wipe sampling to detect preexisting contamination at the 13 study sites showed that overall, 66.7% of samples (104 of 156) had detectable levels of at least 1 marker AHD; subsequent testing after CSTD use per protocol found a sample contamination rate of 5.8% (9 of 156 samples). In the administration areas alone, the rate of preexisting contamination was 78% (61 of 78 samples); with use of the CSTD protocol, the contamination rate was 2.6%. Twenty-six participants rated the CSTD for ease of use, with 100% indicating that they were satisfied or extremely satisfied. A study involving a rigorous protocol and 13 cancer centers across the United States demonstrated that the CSTD reduced surface contamination by cyclophosphamide and fluorouracil during compounding and simulated administration. Participants reported that the CSTD was easy to use. Copyright © 2018 by the American Society of Health-System Pharmacists, Inc. All rights reserved.
Yoshida, Jin; Koda, Shigeki; Nishida, Shozo; Yoshida, Toshiaki; Miyajima, Keiko; Kumagai, Shinji
2011-03-01
The aim of the present study was to evaluate the measurement of contamination by antineoplastic drugs for safer handling of such drugs by medical workers. We investigated the relationship between the contamination level of antineoplastic drugs and the conditions of their handling. Air samples and wipe samples were collected from equipment in the preparation rooms of five hospitals (hospitals A-E). These samples were subjected to measurement of the amounts of cyclophosphamide (CPA), fluorouracil (5FU), gemcitabine (GEM), and platinum-containing drugs (Pt). Twenty-four-hour urine samples were collected from the pharmacists who handled or audited, the antineoplastic drugs were analyzed for CPA and Pt. Pt was detected from air samples inside BSC in hospital B. Antineoplastic drugs were detected from wipe samples of the BSC in hospitals A, B, D, and E and of other equipment in the preparation rooms in hospitals A, B, C, and D. Cyclophosphamide and 5FU were detected from wipe samples of the air-conditioner filter in hospital A, and CPA was detected from that in hospital D. Cyclophosphamide was detected from urine samples of workers in hospitals B, D, and E. The contamination level of antineoplastic drugs was suggested to be related with the amount of drugs handled, cleaning methods of the equipment, and the skill level of the technique of maintaining negative pressure inside a vial. In order to reduce the contamination and exposure to antineoplastic drugs in the hospital work environment very close to zero, comprehensive safety precautions, including adequate mixing and cleaning methods was required in addition to BSC and closed system device.
An inexpensive autosampler for a DART/TOFMS provides mass spectra from analytes absorbed on 76 cotton swab, wipe samples in 7.5 min. A field sample carrier simplifies sample collection and provides swabs nearly ready for analysis to the lab. Applications of the high throughput pr...
40 CFR 761.306 - Sampling 1 meter square surfaces by random selection of halves.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 31 2014-07-01 2014-07-01 false Sampling 1 meter square surfaces by...(b)(3) § 761.306 Sampling 1 meter square surfaces by random selection of halves. (a) Divide each 1 meter square portion where it is necessary to collect a surface wipe test sample into two equal (or as...
40 CFR 761.306 - Sampling 1 meter square surfaces by random selection of halves.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 32 2013-07-01 2013-07-01 false Sampling 1 meter square surfaces by...(b)(3) § 761.306 Sampling 1 meter square surfaces by random selection of halves. (a) Divide each 1 meter square portion where it is necessary to collect a surface wipe test sample into two equal (or as...
40 CFR 761.306 - Sampling 1 meter square surfaces by random selection of halves.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 32 2012-07-01 2012-07-01 false Sampling 1 meter square surfaces by...(b)(3) § 761.306 Sampling 1 meter square surfaces by random selection of halves. (a) Divide each 1 meter square portion where it is necessary to collect a surface wipe test sample into two equal (or as...
40 CFR 761.306 - Sampling 1 meter square surfaces by random selection of halves.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 31 2011-07-01 2011-07-01 false Sampling 1 meter square surfaces by...(b)(3) § 761.306 Sampling 1 meter square surfaces by random selection of halves. (a) Divide each 1 meter square portion where it is necessary to collect a surface wipe test sample into two equal (or as...
40 CFR 761.306 - Sampling 1 meter square surfaces by random selection of halves.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Sampling 1 meter square surfaces by...(b)(3) § 761.306 Sampling 1 meter square surfaces by random selection of halves. (a) Divide each 1 meter square portion where it is necessary to collect a surface wipe test sample into two equal (or as...
Fent, Kenneth W; Alexander, Barbara; Roberts, Jennifer; Robertson, Shirley; Toennis, Christine; Sammons, Deborah; Bertke, Stephen; Kerber, Steve; Smith, Denise; Horn, Gavin
2017-10-01
Firefighters' skin may be exposed to chemicals via permeation/penetration of combustion byproducts through or around personal protective equipment (PPE) or from the cross-transfer of contaminants on PPE to the skin. Additionally, volatile contaminants can evaporate from PPE following a response and be inhaled by firefighters. Using polycyclic aromatic hydrocarbons (PAHs) and volatile organic compounds (VOCs) as respective markers for non-volatile and volatile substances, we investigated the contamination of firefighters' turnout gear and skin following controlled residential fire responses. Participants were grouped into three crews of twelve firefighters. Each crew was deployed to a fire scenario (one per day, four total) and then paired up to complete six fireground job assignments. Wipe sampling of the exterior of the turnout gear was conducted pre- and post-fire. Wipe samples were also collected from a subset of the gear after field decontamination. VOCs off-gassing from gear were also measured pre-fire, post-fire, and post-decon. Wipe sampling of the firefighters' hands and neck was conducted pre- and post-fire. Additional wipes were collected after cleaning neck skin. PAH levels on turnout gear increased after each response and were greatest for gear worn by firefighters assigned to fire attack and to search and rescue activities. Field decontamination using dish soap, water, and scrubbing was able to reduce PAH contamination on turnout jackets by a median of 85%. Off-gassing VOC levels increased post-fire and then decreased 17-36 min later regardless of whether field decontamination was performed. Median post-fire PAH levels on the neck were near or below the limit of detection (< 24 micrograms per square meter [µg/m 2 ]) for all positions. For firefighters assigned to attack, search, and outside ventilation, the 75 th percentile values on the neck were 152, 71.7, and 39.3 µg/m 2 , respectively. Firefighters assigned to attack and search had higher post-fire median hand contamination (135 and 226 µg/m 2 , respectively) than other positions (< 10.5 µg/m 2 ). Cleansing wipes were able to reduce PAH contamination on neck skin by a median of 54%.
Sample collection of virulent and non-virulent B. anthracis and Y. pestis for bioforensics analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hong-geller, Elizabeth; Valdez, Yolanda E; Shou, Yulin
2009-01-01
Validated sample collection methods are needed for recovery of microbial evidence in the event of accidental or intentional release of biological agents into the environment. To address this need, we evaluated the sample recovery efficiencies of two collection methods -- swabs and wipes -- for both non-virulent and virulent strains of B. anthracis and Y. pestis from four types of non-porous surfaces: two hydrophilic surfaces, stainless steel and glass, and two hydrophobic surfaces, vinyl and plastic. Sample recovery was quantified using Real-time qPCR to assay for intact DNA signatures. We found no consistent difference in collection efficiency between swabs ormore » wipes. Furthermore, collection efficiency was more surface-dependent for virulent strains than non-virulent strains. For the two non-virulent strains, B. anthracis Sterne and Y. pestis A1122, collection efficiency was approximately 100% and 1 %, respectively, from all four surfaces. In contrast, recovery of B. anthracis Ames spores and Y. pestis C092 from vinyl and plastic was generally lower compared to collection from glass or stainless steel, suggesting that surface hydrophobicity may playa role in the strength of pathogen adhesion. The surface-dependent collection efficiencies observed with the virulent strains may arise from strain-specific expression of capsular material or other cell surface receptors that alter cell adhesion to specific surfaces. These findings contribute to validation of standard bioforensics procedures and emphasize the importance of specific strain and surface interactions in pathogen detection.« less
Hong-Geller, E; Valdez, Y E; Shou, Y; Yoshida, T M; Marrone, B L; Dunbar, J M
2010-04-01
We will validate sample collection methods for recovery of microbial evidence in the event of accidental or intentional release of biological agents into the environment. We evaluated the sample recovery efficiencies of two collection methods - swabs and wipes - for both nonvirulent and virulent strains of Bacillus anthracis and Yersinia pestis from four types of nonporous surfaces: two hydrophilic surfaces, stainless steel and glass, and two hydrophobic surfaces, vinyl and plastic. Sample recovery was quantified using real-time qPCR to assay for intact DNA signatures. We found no consistent difference in collection efficiency between swabs or wipes. Furthermore, collection efficiency was more surface-dependent for virulent strains than nonvirulent strains. For the two nonvirulent strains, collection efficiency was similar between all four surfaces, albeit B. anthracis Sterne exhibited higher levels of recovery compared to Y. pestis A1122. In contrast, recovery of B. anthracis Ames spores and Y. pestis CO92 from the hydrophilic glass or stainless steel surfaces was generally more efficient compared to collection from the hydrophobic vinyl and plastic surfaces. Our results suggest that surface hydrophobicity may play a role in the strength of pathogen adhesion. The surface-dependent collection efficiencies observed with the virulent strains may arise from strain-specific expression of capsular material or other cell surface receptors that alter cell adhesion to specific surfaces. These findings contribute to the validation of standard bioforensics procedures and emphasize the importance of specific strain and surface interactions in pathogen detection.
EPA collected ambient air samples in lower Manhattan for about nine months following the September 11, 2001 (9/11) World Trade Center (WTC) attacks. Measurements were made of a host of airborne contaminants including volatile organic compounds (VOCs), polycyclic aromatic hydroca...
This SOP summarizes the method for extracting and preparing a hard floor surface wipe or food preparation surface wipe sample for analysis of neutral persistent organic. It covers the extraction and concentration of samples that are to be analyzed by gas chromatography/mass spect...
The purpose of this SOP is to describe procedures for extracting and preparing a dermal wipe sample for GC/MS analysis of pesticides. This procedure was followed to ensure consistent data retrieval during the Arizona NHEXAS project and the "Border" study. Keywords: dermal wipe;...
The purpose of this SOP is to describe procedures for extracting and preparing a dermal wipe sample for GC/MS analysis of pesticides. This procedure was followed to ensure consistent data retrieval during the Arizona NHEXAS project and the Border study. Keywords: dermal wipe; p...
Morgan, Marsha K.
2012-01-01
Pyrethroid insecticides are frequently used to control insects in residential and agriculture settings in the United States and worldwide. As a result, children can be potentially exposed to pyrethroid residues in food and at home. This review summarizes data reported in 15 published articles from observational exposure measurement studies conducted from 1999 to present that examined children’s (5 months to 17 years of age) exposures to pyrethroids in media including floor wipes, floor dust, food, air, and/or urine collected at homes in the United States. At least seven different pyrethroids were detected in wipe, dust, solid food, and indoor air samples. Permethrin was the most frequently detected (>50%) pyrethroid in these media, followed by cypermethrin (wipes, dust, and food). 3-phenoxybenzoic acid (3-PBA), a urinary metabolite of several pyrethroids, was the most frequently (≥67%) detected pyrethroid biomarker. Results across studies indicate that these children were likely exposed to several pyrethroids, but primarily to permethrin and cypermethrin, from several sources including food, dust, and/or on surfaces at residences. Dietary ingestion followed by nondietary ingestion were the dominate exposure routes for these children, except in homes with frequent pesticide applications (dermal followed by dietary ingestion). Urinary 3-PBA concentration data confirm that the majority of the children sampled were exposed to one or more pyrethroids. PMID:23066409
Lutz, J K; Crawford, J; Hoet, A E; Wilkins, J R; Lee, J
2013-07-01
To evaluate the performance of four sampling methods [contact plates, electrostatic wipes (wipe), swabs and a novel roller sampler] for recovery of Staphylococcus aureus from a stainless steel surface. Stainless steel test plates were inoculated with Staph. aureus, dried for 24 h and sampled using each of the four methods. Samples were either incubated directly (roller, contact plate) or processed using elution and membrane filtration (swab, wipe). Performance was assessed by calculating the apparent sampling efficiency (ASE), analytical sensitivity (Sn) and percentage of replications with positive growth. The wipe demonstrated the best performance across all inoculating concentrations (ASE(48 h) = 18%; Sn(48 h) = 7 CFU per 100 cm(2)). The swab performed well when corrected for area actually sampled (ASE(48 h) = 24%; Sn(48 h) = 76 CFU per 100 cm(2)). Of the contact-based methods, the newly developed roller sampler outperformed the contact plate (roller: ASE(48 h) = 10%; Sn(48 h) = 17 CFU per 100 cm(2); contact plate: ASE(48 h) = 0·04%; Sn(48 h) = 1412 CFU per 100 cm(2)); both contact samplers performed better at higher inoculating concentrations (6E3 CFU per 100 cm(2) for the roller and 6E6 CFU per 100 cm(2) for the contact plate). Overall, the electrostatic wipe produced the highest number of replications resulting in positive growth (74%(24 h), 91%(48 h)). This study demonstrates that selection of the sampling method must be carefully considered, given that different methods have varying performance. This is the first study assessing static wipes for sampling and one that uses a more real-world-relevant 24-h drying time. The results help with infection control, and environmental health professionals choose better sampling methodologies. Journal of Applied Microbiology © 2013 The Society for Applied Microbiology.
A MULTI-RESIDUE METHOD FOR THE ANALYSIS OF INSECTICIDES COLLECTED ON COTTON SURFACE WIPES
A method was developed for the extraction, clean-up, and analysis of multiple pesticides from cotton wipe media used in human exposure studies to collect residues from residential hard surfaces. Measurements of pesticides are critical for estimating dermal and indirect ingestion ...
Facilities Management Guide for Asbestos and Lead
2004-11-01
equipment such as HEPA filtered power tools, portable welding exhaust systems, and paint removal equipment when work disturbs lead. Do not dry sweep ...sampling and analysis of [______] paint bulk and wipe samples by atomic absorption spectrophotometry (AA) or anodic stripping voltametry (ASV...analysis. e. All bulk (destructive) collected for lead shall be analyzed by atomic absorption spectrophotometry (AA) or anodic stripping voltametry
Monitoring Indoor Exposure to Organophosphate Flame Retardants: Hand Wipes and House Dust
Hoffman, Kate; Garantziotis, Stavros; Birnbaum, Linda S.
2014-01-01
Background: Organophosphate flame retardants (PFRs) are becoming popular replacements for the phased-out polybrominated diphenyl ether (PBDE) mixtures, and they are now commonly detected in indoor environments. However, little is known about human exposure to PFRs because they cannot be easily measured in blood or serum. Objectives: To investigate relationships between the home environment and internal exposure, we assessed associations between two PFRs, tris(1,3-dichloropropyl) phosphate (TDCIPP) and triphenyl phosphate (TPHP), in paired hand wipe and dust samples and concentrations of their metabolites in urine samples (n = 53). We also assessed short-term variation in urinary metabolite concentrations (n = 11 participants; n = 49 samples). Methods: Adult volunteers in North Carolina, USA, completed questionnaires and provided urine, hand wipe, and household dust samples. PFRs and PBDEs were measured in hand wipes and dust, and bis(1,3-dichloropropyl) phosphate (BDCIPP) and diphenyl phosphate (DPHP), metabolites of TDCIPP and TPHP, were measured in urine. Results: TDCIPP and TPHP were detected frequently in hand wipes and dust (> 86.8%), with geometric mean concentrations exceeding those of PBDEs. Unlike PBDEs, dust TDCIPP and TPHP levels were not associated with hand wipes. However, hand wipe levels were associated with urinary metabolites. Participants with the highest hand wipe TPHP mass, for instance, had DPHP levels 2.42 times those of participants with the lowest levels (95% CI: 1.23, 4.77). Women had higher levels of DPHP, but not BDCIPP. BDCIPP and DPHP concentrations were moderately to strongly reliable over 5 consecutive days (intraclass correlation coefficients of 0.81 and 0.51, respectively). Conclusions: PFR exposures are widespread, and hand-to-mouth contact or dermal absorption may be important pathways of exposure. Citation: Hoffman K, Garantziotis S, Birnbaum LS, Stapleton HM. 2015. Monitoring indoor exposure to organophosphate flame retardants: hand wipes and house dust. Environ Health Perspect 123:160–165; http://dx.doi.org/10.1289/ehp.1408669 PMID:25343780
A Study on the Reliability of an On-Site Oral Fluid Drug Test in a Recreational Context
Gentili, Stefano; Tittarelli, Roberta; Mannocchi, Giulio
2016-01-01
The reliability of DrugWipe 5A on site test for principal drugs of abuse (cannabis, amphetamines, cocaine, and opiates) detection in oral fluid was assessed by comparing the on-site results with headspace solid-phase microextraction (HS-SPME) gas chromatography-mass spectrometry (GC-MS) analysis on samples extracted by the device collection pad. Oral fluid samples were collected at recreational settings (e.g., discos, pubs, and music bars) of Rome metropolitan area. Eighty-three club goers underwent the on-site drug screening test with one device. Independently from the result obtained, a second device was used just to collect another oral fluid sample subsequently extracted and analyzed in the laboratory following HS-SPME procedure, gas chromatographic separation by a capillary column, and MS detection by electron impact ionization. DrugWipe 5A on-site test showed 54 samples (65.1%) positive to one or more drugs of abuse, whereas 75 samples (90.4%) tested positive for one or more substances following GC-MS assay. Comparing the obtained results, the device showed sensitivity, specificity, and accuracy around 80% for amphetamines class. Sensitivity (67 and 50%) was obtained for cocaine and opiates, while both sensitivity and accuracy were unsuccessful (29 and 53%, resp.) for cannabis, underlying the limitation of the device for this latter drug class. PMID:27610266
Emery, R J
1997-03-01
Institutional radiation safety programs routinely use wipe test sampling and liquid scintillation counting analysis to indicate the presence of removable radioactive contamination. Significant volumes of liquid waste can be generated by such surveillance activities, and the subsequent disposal of these materials can sometimes be difficult and costly. In settings where large numbers of negative results are regularly obtained, the limited grouping of samples for analysis based on expected value statistical techniques is possible. To demonstrate the plausibility of the approach, single wipe samples exposed to varying amounts of contamination were analyzed concurrently with nine non-contaminated samples. Although the sample grouping inevitably leads to increased quenching with liquid scintillation counting systems, the effect did not impact the ability to detect removable contamination in amounts well below recommended action levels. Opportunities to further improve this cost effective semi-quantitative screening procedure are described, including improvements in sample collection procedures, enhancing sample-counting media contact through mixing and extending elution periods, increasing sample counting times, and adjusting institutional action levels.
Assessment of skin exposure to nickel, chromium and cobalt by acid wipe sampling and ICP-MS.
Lidén, Carola; Skare, Lizbet; Lind, Birger; Nise, Gun; Vahter, Marie
2006-05-01
There is a great need to accurately assess skin exposure to contact allergens. We have developed a technique for assessment of skin exposure to nickel, chromium and cobalt using acid wipe sampling by cellulose wipes with 1% nitric acid. Chemical analysis was performed by inductively coupled plasma mass spectrometry (ICP-MS). The recovery of nickel, chromium and cobalt from arms and palms was 93%. The analytical result is expressed in terms of mass per unit area (microg/cm(2)). The developed acid wipe sampling technique is suitable for determination of nickel, chromium and cobalt deposited on the skin. The technique may be used in workplace studies, in studies of individuals in the general population, in dermatitis patients, in identification of risk groups, as well as in developing preventive strategies and in follow-up after intervention.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Piepel, Gregory F.; Amidan, Brett G.; Krauter, Paula
2011-05-01
Two concerns were raised by the Government Accountability Office following the 2001 building contaminations via letters containing Bacillus anthracis (BA). These included the: 1) lack of validated sampling methods, and 2) need to use statistical sampling to quantify the confidence of no contamination when all samples have negative results. Critical to addressing these concerns is quantifying the false negative rate (FNR). The FNR may depend on the 1) method of contaminant deposition, 2) surface concentration of the contaminant, 3) surface material being sampled, 4) sample collection method, 5) sample storage/transportation conditions, 6) sample processing method, and 7) sample analytical method.more » A review of the literature found 17 laboratory studies that focused on swab, wipe, or vacuum samples collected from a variety of surface materials contaminated by BA or a surrogate, and used culture methods to determine the surface contaminant concentration. These studies quantified performance of the sampling and analysis methods in terms of recovery efficiency (RE) and not FNR (which left a major gap in available information). Quantifying the FNR under a variety of conditions is a key aspect of validating sample and analysis methods, and also for calculating the confidence in characterization or clearance decisions based on a statistical sampling plan. A laboratory study was planned to partially fill the gap in FNR results. This report documents the experimental design developed by Pacific Northwest National Laboratory and Sandia National Laboratories (SNL) for a sponge-wipe method. The testing was performed by SNL and is now completed. The study investigated the effects on key response variables from six surface materials contaminated with eight surface concentrations of a BA surrogate (Bacillus atrophaeus). The key response variables include measures of the contamination on test coupons of surface materials tested, contamination recovered from coupons by sponge-wipe samples, RE, and FNR. The experimental design involves 16 test runs, performed in two blocks of eight runs. Three surface materials (stainless steel, vinyl tile, and ceramic tile) were tested in the first block, while three other surface materials (plastic, painted wood paneling, and faux leather) were tested in the second block. The eight surface concentrations of the surrogate were randomly assigned to test runs within each block. Some of the concentrations were very low and presented challenges for deposition, sampling, and analysis. However, such tests are needed to investigate RE and FNR over the full range of concentrations of interest. In each run, there were 10 test coupons of each of the three surface materials. A positive control sample was generated at the same time as each test sample. The positive control results will be used to 1) calculate RE values for the wipe sampling and analysis method, and 2) fit RE- and FNR-concentration equations, for each of the six surface materials. Data analyses will support 1) estimating the FNR for each combination of contaminant concentration and surface material, 2) estimating the surface concentrations and their uncertainties of the contaminant for each combination of concentration and surface material, 3) estimating RE (%) and their uncertainties for each combination of contaminant concentration and surface material, 4) fitting FNR-concentration and RE-concentration equations for each of the six surface materials, 5) assessing goodness-of-fit of the equations, and 6) quantifying the uncertainty in FNR and RE predictions made with the fitted equations.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Piepel, Gregory F.; Amidan, Brett G.; Krauter, Paula
2010-12-16
Two concerns were raised by the Government Accountability Office following the 2001 building contaminations via letters containing Bacillus anthracis (BA). These included the: 1) lack of validated sampling methods, and 2) need to use statistical sampling to quantify the confidence of no contamination when all samples have negative results. Critical to addressing these concerns is quantifying the probability of correct detection (PCD) (or equivalently the false negative rate FNR = 1 - PCD). The PCD/FNR may depend on the 1) method of contaminant deposition, 2) surface concentration of the contaminant, 3) surface material being sampled, 4) sample collection method, 5)more » sample storage/transportation conditions, 6) sample processing method, and 7) sample analytical method. A review of the literature found 17 laboratory studies that focused on swab, wipe, or vacuum samples collected from a variety of surface materials contaminated by BA or a surrogate, and used culture methods to determine the surface contaminant concentration. These studies quantified performance of the sampling and analysis methods in terms of recovery efficiency (RE) and not PCD/FNR (which left a major gap in available information). Quantifying the PCD/FNR under a variety of conditions is a key aspect of validating sample and analysis methods, and also for calculating the confidence in characterization or clearance decisions based on a statistical sampling plan. A laboratory study was planned to partially fill the gap in PCD/FNR results. This report documents the experimental design developed by Pacific Northwest National Laboratory and Sandia National Laboratories (SNL) for a sponge-wipe method. The study will investigate the effects on key response variables from six surface materials contaminated with eight surface concentrations of a BA surrogate (Bacillus atrophaeus). The key response variables include measures of the contamination on test coupons of surface materials tested, contamination recovered from coupons by sponge-wipe samples, RE, and PCD/FNR. The experimental design involves 16 test runs, to be performed in two blocks of eight runs. Three surface materials (stainless steel, vinyl tile, and ceramic tile) were tested in the first block, while three other surface materials (plastic, painted wood paneling, and faux leather) will be tested in the second block. The eight surface concentrations of the surrogate were randomly assigned to test runs within each block. Some of the concentrations will be very low and may present challenges for deposition, sampling, and analysis. However, such tests are needed to investigate RE and PCD/FNR over the full range of concentrations of interest. In each run, there will be 10 test coupons of each of the three surface materials. A positive control sample will be generated prior to each test sample. The positive control results will be used to 1) calculate RE values for the wipe sampling and analysis method, and 2) fit RE- and PCD-concentration equations, for each of the six surface materials. Data analyses will support 1) estimating the PCD for each combination of contaminant concentration and surface material, 2) estimating the surface concentrations and their uncertainties of the contaminant for each combination of concentration and surface material, 3) estimating RE (%) and their uncertainties for each combination of contaminant concentration and surface material, 4) fitting PCD-concentration and RE-concentration equations for each of the six surface materials, 5) assessing goodness-of-fit of the equations, and 6) quantifying the uncertainty in PCD and RE predictions made with the fitted equations.« less
Willison, Stuart A
2015-01-20
The persistence of chemical warfare nerve agent degradation analytes on surfaces is important, from indicating the presence of nerve agent on a surface to guiding environmental restoration of a site after a release. Persistence was investigated for several chemical warfare nerve agent degradation analytes on indoor surfaces and presents an approach for wipe sampling of surfaces, followed by wipe extraction and liquid chromatography-tandem mass spectrometry detection. Commercially available wipe materials were investigated to determine optimal wipe recoveries. Tested surfaces included porous/permeable (vinyl tile, painted drywall, and wood) and largely nonporous/impermeable (laminate, galvanized steel, and glass) surfaces. Wipe extracts were analyzed by ultrahigh performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). UPLC provides a separation of targeted degradation analytes in addition to being nearly four times faster than high-performance liquid chromatography, allowing for greater throughput after a large-scale contamination incident and subsequent remediation events. Percent recoveries from nonporous/impermeable surfaces were 60-103% for isopropyl methylphosphonate (IMPA), GB degradate; 61-91% for ethyl methylphosphonate (EMPA), VX degradate; and 60-98% for pinacolyl methylphosphonate (PMPA), GD degradate. Recovery efficiencies for methyl phosphonate (MPA), nerve agent degradate, and ethylhydrogen dimethylphosphonate (EHDMAP), GA degradate, were lower, perhaps due to matrix effects. Diisopropyl methylphosphonate, GB impurity, was not recovered from surfaces. The resulting detection limits for wipe extracts were 0.065 ng/cm(2) for IMPA, 0.079 ng/cm(2) for MPA, 0.040 ng/cm(2) for EMPA, 0.078 ng/cm(2) for EHDMAP, and 0.013 ng/cm(2) for PMPA. The data indicate that laboratories may hold wipe samples for up to 30 days prior to analysis. Target analytes were observed to persist on surfaces for at least 6 weeks.
Calfee, M. Worth; Tufts, Jenia; Meyer, Kathryn; McConkey, Katrina; Mickelsen, Leroy; Rose, Laura; Dowell, Chad; Delaney, Lisa; Weber, Angela; Morse, Stephen; Chaitram, Jasmine; Gray, Marshall
2016-01-01
Sample collection procedures and primary receptacle (sample container and bag) decontamination methods should prevent contaminant transfer between contaminated and non-contaminated surfaces and areas during bio-incident operations. Cross-contamination of personnel, equipment, or sample containers may result in the exfiltration of biological agent from the exclusion (hot) zone and have unintended negative consequences on response resources, activities and outcomes. The current study was designed to: (1) evaluate currently recommended sample collection and packaging procedures to identify procedural steps that may increase the likelihood of spore exfiltration or contaminant transfer; (2) evaluate the efficacy of currently recommended primary receptacle decontamination procedures; and (3) evaluate the efficacy of outer packaging decontamination methods. Wet- and dry-deposited fluorescent tracer powder was used in contaminant transfer tests to qualitatively evaluate the currently-recommended sample collection procedures. Bacillus atrophaeus spores, a surrogate for Bacillus anthracis, were used to evaluate the efficacy of spray- and wipe-based decontamination procedures. Both decontamination procedures were quantitatively evaluated on three types of sample packaging materials (corrugated fiberboard, polystyrene foam, and polyethylene plastic), and two contamination mechanisms (wet or dry inoculums). Contaminant transfer results suggested that size-appropriate gloves should be worn by personnel, templates should not be taped to or removed from surfaces, and primary receptacles should be selected carefully. The decontamination tests indicated that wipe-based decontamination procedures may be more effective than spray-based procedures; efficacy was not influenced by material type but was affected by the inoculation method. Incomplete surface decontamination was observed in all tests with dry inoculums. This study provides a foundation for optimizing current B. anthracis response procedures to minimize contaminant exfiltration. PMID:27362274
Calfee, M Worth; Tufts, Jenia; Meyer, Kathryn; McConkey, Katrina; Mickelsen, Leroy; Rose, Laura; Dowell, Chad; Delaney, Lisa; Weber, Angela; Morse, Stephen; Chaitram, Jasmine; Gray, Marshall
2016-12-01
Sample collection procedures and primary receptacle (sample container and bag) decontamination methods should prevent contaminant transfer between contaminated and non-contaminated surfaces and areas during bio-incident operations. Cross-contamination of personnel, equipment, or sample containers may result in the exfiltration of biological agent from the exclusion (hot) zone and have unintended negative consequences on response resources, activities and outcomes. The current study was designed to: (1) evaluate currently recommended sample collection and packaging procedures to identify procedural steps that may increase the likelihood of spore exfiltration or contaminant transfer; (2) evaluate the efficacy of currently recommended primary receptacle decontamination procedures; and (3) evaluate the efficacy of outer packaging decontamination methods. Wet- and dry-deposited fluorescent tracer powder was used in contaminant transfer tests to qualitatively evaluate the currently-recommended sample collection procedures. Bacillus atrophaeus spores, a surrogate for Bacillus anthracis, were used to evaluate the efficacy of spray- and wipe-based decontamination procedures. Both decontamination procedures were quantitatively evaluated on three types of sample packaging materials (corrugated fiberboard, polystyrene foam, and polyethylene plastic), and two contamination mechanisms (wet or dry inoculums). Contaminant transfer results suggested that size-appropriate gloves should be worn by personnel, templates should not be taped to or removed from surfaces, and primary receptacles should be selected carefully. The decontamination tests indicated that wipe-based decontamination procedures may be more effective than spray-based procedures; efficacy was not influenced by material type but was affected by the inoculation method. Incomplete surface decontamination was observed in all tests with dry inoculums. This study provides a foundation for optimizing current B. anthracis response procedures to minimize contaminant exfiltration.
The method for extracting and preparing a dermal (hand) wipe sample for analysis of neutral persistent organic pollutants is summarized in this SOP. It covers the extraction and concentration of samples that are to be analyzed by gas chromatography/mass spectrometry.
Estill, Cheryl Fairfield; Baron, Paul A.; Beard, Jeremy K.; Hein, Misty J.; Larsen, Lloyd D.; Rose, Laura; Schaefer, Frank W.; Noble-Wang, Judith; Hodges, Lisa; Lindquist, H. D. Alan; Deye, Gregory J.; Arduino, Matthew J.
2009-01-01
After the 2001 anthrax incidents, surface sampling techniques for biological agents were found to be inadequately validated, especially at low surface loadings. We aerosolized Bacillus anthracis Sterne spores within a chamber to achieve very low surface loading (ca. 3, 30, and 200 CFU per 100 cm2). Steel and carpet coupons seeded in the chamber were sampled with swab (103 cm2) or wipe or vacuum (929 cm2) surface sampling methods and analyzed at three laboratories. Agar settle plates (60 cm2) were the reference for determining recovery efficiency (RE). The minimum estimated surface concentrations to achieve a 95% response rate based on probit regression were 190, 15, and 44 CFU/100 cm2 for sampling steel surfaces and 40, 9.2, and 28 CFU/100 cm2 for sampling carpet surfaces with swab, wipe, and vacuum methods, respectively; however, these results should be cautiously interpreted because of high observed variability. Mean REs at the highest surface loading were 5.0%, 18%, and 3.7% on steel and 12%, 23%, and 4.7% on carpet for the swab, wipe, and vacuum methods, respectively. Precision (coefficient of variation) was poor at the lower surface concentrations but improved with increasing surface concentration. The best precision was obtained with wipe samples on carpet, achieving 38% at the highest surface concentration. The wipe sampling method detected B. anthracis at lower estimated surface concentrations and had higher RE and better precision than the other methods. These results may guide investigators to more meaningfully conduct environmental sampling, quantify contamination levels, and conduct risk assessment for humans. PMID:19429546
Estill, Cheryl Fairfield; Baron, Paul A; Beard, Jeremy K; Hein, Misty J; Larsen, Lloyd D; Rose, Laura; Schaefer, Frank W; Noble-Wang, Judith; Hodges, Lisa; Lindquist, H D Alan; Deye, Gregory J; Arduino, Matthew J
2009-07-01
After the 2001 anthrax incidents, surface sampling techniques for biological agents were found to be inadequately validated, especially at low surface loadings. We aerosolized Bacillus anthracis Sterne spores within a chamber to achieve very low surface loading (ca. 3, 30, and 200 CFU per 100 cm(2)). Steel and carpet coupons seeded in the chamber were sampled with swab (103 cm(2)) or wipe or vacuum (929 cm(2)) surface sampling methods and analyzed at three laboratories. Agar settle plates (60 cm(2)) were the reference for determining recovery efficiency (RE). The minimum estimated surface concentrations to achieve a 95% response rate based on probit regression were 190, 15, and 44 CFU/100 cm(2) for sampling steel surfaces and 40, 9.2, and 28 CFU/100 cm(2) for sampling carpet surfaces with swab, wipe, and vacuum methods, respectively; however, these results should be cautiously interpreted because of high observed variability. Mean REs at the highest surface loading were 5.0%, 18%, and 3.7% on steel and 12%, 23%, and 4.7% on carpet for the swab, wipe, and vacuum methods, respectively. Precision (coefficient of variation) was poor at the lower surface concentrations but improved with increasing surface concentration. The best precision was obtained with wipe samples on carpet, achieving 38% at the highest surface concentration. The wipe sampling method detected B. anthracis at lower estimated surface concentrations and had higher RE and better precision than the other methods. These results may guide investigators to more meaningfully conduct environmental sampling, quantify contamination levels, and conduct risk assessment for humans.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Que Hee, S.S.; Peace, B.; Clark, C.S.
Efficient sampling methods to recover lead-containing house dust and hand dust have been evolved so that sufficient lead is collected for analysis and to ensure that correlational analyses linking these two parameters to blood lead are not dependent on the efficiency of sampling. Precise collection of loose house dust from a 1-unit area (484 cmS) with a Tygon or stainless steel sampling tube connected to a portable sampling pump (1.2 to 2.5 liters/min) required repetitive sampling (three times). The Tygon tube sampling technique for loose house dust <177 m in diameter was around 72% efficient with respect to dust weightmore » and lead collection. A representative house dust contained 81% of its total weight in this fraction. A single handwipe for applied loose hand dust was not acceptably efficient or precise, and at least three wipes were necessary to achieve recoveries of >80% of the lead applied. House dusts of different particle sizes <246 m adhered equally well to hands. Analysis of lead-containing material usually required at least three digestions/decantations using hot plate or microwave techniques to allow at least 90% of the lead to be recovered. It was recommended that other investigators validate their handwiping, house dust sampling, and digestion techniques to facilitate comparison of results across studies. The final methodology for the Cincinnati longitudinal study was three sampling passes for surface dust using a stainless steel sampling tube; three microwave digestion/decantations for analysis of dust and paint; and three wipes with handwipes with one digestion/decantation for the analysis of six handwipes together.« less
Solbu, Kasper; Daae, Hanne Line; Olsen, Raymond; Thorud, Syvert; Ellingsen, Dag Gunnar; Lindgren, Torsten; Bakke, Berit; Lundanes, Elsa; Molander, Paal
2011-05-01
Methods for measurements and the potential for occupational exposure to organophosphates (OPs) originating from turbine and hydraulic oils among flying personnel in the aviation industry are described. Different sampling methods were applied, including active within-day methods for OPs and VOCs, newly developed passive long-term sample methods (deposition of OPs to wipe surface areas and to activated charcoal cloths), and measurements of OPs in high-efficiency particulate air (HEPA) recirculation filters (n = 6). In total, 95 and 72 within-day OP and VOC samples, respectively, have been collected during 47 flights in six different models of turbine jet engine, propeller and helicopter aircrafts (n = 40). In general, the OP air levels from the within-day samples were low. The most relevant OP in this regard originating from turbine and engine oils, tricresyl phosphate (TCP), was detected in only 4% of the samples (min-max
Evaluation of Chemical Warfare Agent Wipe Sampling ...
Report This investigation tested specific (CWAs), including sarin (GB), soman (GD), cyclosarin (GF), sulfur mustard (HD), and O-ethyl-S-(2-diisopropylaminoethyl) methylphosphonothioate (VX) on the non-ideal (e.g., porous and permeable) surfaces of drywall, vinyl tile, wood, laminate, and coated glass. Pesticides (diazinon and malathion) were used so that a comparison is possible with existing literature data (1). Experiments included testing with coupons having surface areas of 10 cm2 and 100 cm2. The 10-cm2 coupons were of a size that could easily be extracted in a 2 oz jar (to provide comparative data for CWA recoveries generated by direct extraction) and the 100-cm2 coupons better represented the area of a surface that might typically be sampled by wipe extraction. In addition, CWA, at a normalized surface concentration of 0.1 µg per cm2 surface area, were spiked on coupons of the tested surfaces. Wipes were wetted with either dichloromethane (DCM) or isopropanol (IPA) before sampling for CWA. Experimental parameters include multiple wipe types, porous/permeable surfaces, coupon surface area, solvent used to wet the wipe (i.e., wetting solvent), and the utility of VX-d14 as an extracted internal standard.
Warshaw, Erin M; Aschenbeck, Kelly A; Zug, Kathryn A; Belsito, Donald V; Zirwas, Matthew J; Fowler, Joseph F; Taylor, James S; Sasseville, Denis; Fransway, Anthony F; DeLeo, Vincent A; Marks, James G; Pratt, Melanie D; Maibach, Howard I; Mathias, C G Toby; DeKoven, Joel G
Although there are several case reports of wet wipe-associated contact dermatitis, the prevalence of wipes as a source of allergic contact dermatitis in larger populations and the responsible allergens are largely unknown. The aim of the study was to determine the prevalence of wet wipes as a source of contact allergy and the most commonly associated allergens in a North American tertiary referral patch test population. Data collected from 2011 to 2014 by the North American Contact Dermatitis Group was used to conduct a retrospective cross-sectional analysis of patient demographics and patch test results associated with the triple-digit source code for "wet wipe." Of the 9037 patients patch tested during the study period, 79 (0.9%) had a positive patch test reaction to an allergen identified with a wet wipe source. The most commonly associated allergens were preservatives, including the following: methylisothiazolinone (MI) (59.0%), methylchloroisothiazolinone (MCI)/MI (35.6%), bronopol (2-bromo-2-nitropropane-1,3-diol) (27.4%), and iodopropynyl butylcarbamate (12.3%). Fragrance (combined) represented 12.3%. Anal/genital dermatitis was 15 times more likely (P < 0.0001) in those with wet wipe allergy. More than 92% of patients with wipe-associated contact allergy had their contact allergens detected by the North American Contact Dermatitis Group screening series. Wet wipes are an important source of contact allergy. Preservatives are the main allergens, especially isothiazolinones.
Design concept definition study for an improved shuttle waste collection subsystem
NASA Technical Reports Server (NTRS)
1984-01-01
A no-risk approach for developing an Improved Waste Collection Subsystem (WCS) for the shuttle orbiter is described. The GE Improved WCS Concept builds on the experience of 14 Shuttle missions with over 400 man-days of service. This concept employs the methods of the existing flight-proven mature design, augmenting them to eliminate foreseen difficulties and to fully comply with the design requirements. The GE Improved WCS Concept includes separate storage for used wipes. Compaction of the wipes provides a solution to the capacity problem, fully satisfying the 210 man-day storage requirement. The added feature of in-flight serviceable storage space for the wipes creates a variable capacity feature which affords redundancy in the event of wipes compaction system failure. Addition of features permitting in-flight servicing of the feces storage tank creates a variable capacity WCS with easier post-flight servicing to support rapid turnaround of the Shuttle orbiter. When these features are combined with a vacuum pump to evacuate wipes and fecal storage tanks through replaceable odor/bacteria filters to the cabin, the GE Improved WCS satisfies the known requirements for Space Station use, including no venting to space.
Ruple-Czerniak, A; Bolte, D S; Burgess, B A; Morley, P S
2014-07-01
Nosocomial salmonellosis is an important problem in veterinary hospitals that treat horses and other large animals. Detection and mitigation of outbreaks and prevention of healthcare-associated infections often require detection of Salmonella enterica in the hospital environment. To compare 2 previously published methods for detecting environmental contamination with S. enterica in a large animal veterinary teaching hospital. Hospital-based comparison of environmental sampling techniques. A total of 100 pairs of environmental samples were collected from stalls used to house large animal cases (horses, cows or New World camelids) that were confirmed to be shedding S. enterica by faecal culture. Stalls were cleaned and disinfected prior to sampling, and the same areas within each stall were sampled for the paired samples. One method of detection used sterile, premoistened sponges that were cultured using thioglycolate enrichment before plating on XLT-4 agar. The other method used electrostatic wipes that were cultured using buffered peptone water, tetrathionate and Rappaport-Vassiliadis R10 broths before plating on XLT-4 agar. Salmonella enterica was recovered from 14% of samples processed using the electrostatic wipe sampling and culture procedure, whereas S. enterica was recovered from only 4% of samples processed using the sponge sampling and culture procedure. There was test agreement for 85 pairs of culture-negative samples and 3 pairs of culture-positive samples. However, the remaining 12 pairs of samples with discordant results created significant disagreement between the 2 detection methods (P<0.01). Persistence of Salmonella in the environment of veterinary hospitals can occur even with rigorous cleaning and disinfection. Use of sensitive methods for detection of environmental contamination is critical when detecting and mitigating this problem in veterinary hospitals. These results suggest that the electrostatic wipe sampling and culture method was more sensitive than the sponge sampling and culture method. © 2013 EVJ Ltd.
Stone, Kahler W.; Kirsch, Katie R.; Camargo, Krisa; Wade, Terry L.; McDonald, Thomas J.
2018-01-01
Introduction Polycyclic aromatic hydrocarbons (PAHs) are complex environmental toxicants. Exposure to them has been linked to adverse health outcomes including cancer, as well as diseases of the skin, liver, and immune system. Based on an ongoing community engagement partnership with stakeholder groups and residents, we conducted a small longitudinal study to assess domestic exposure to PAHs among residents of Manchester, an environmental justice neighborhood located in the East End of Houston, TX. Methods In December, 2016, we used fiber wipes to collect samples of household dust from 25 homes in Manchester. Following Hurricane Harvey, in September 2017, we revisited 24 of the 25 homes to collect soil samples from the front yards of the same homes. Wipes and soil were analyzed for the presence of PAHs using gas chromatography–mass spectrometry (GC-MS) methods. Principal component analysis plots, heatmaps, and PAH ratios were used to compare pre- and post-Hurricane Harvey samples. Results While direct comparison is not possible, we present three methods for comparing PAHs found in pre-hurricane fiber wipes and post-hurricane soil samples. The methods demonstrate that the PAHs found before and after Hurricane Harvey are likely from similar sources and that those sources are most likely to be associated with combustion. We also found evidence of redistribution of PAHs due to extreme flooding associated with Hurricane Harvey. Discussion Residents of the Manchester neighborhood of Houston, TX, are exposed to a range of PAHs in household dust and outdoor soil. While it was not possible to compare directly, we were able to use several methods to assess detected concentrations, changes in site-specific PAH allocations, and PAH origination. Additional research is needed to identify specific sources of domestic PAH exposure in these communities and continued work involving community members and policy makers should aim to develop interventions to reduce domestic exposure to and prevent negative health outcomes from PAHs. PMID:29420658
DOE Office of Scientific and Technical Information (OSTI.GOV)
Horney, Jennifer A.; Casillas, Gaston A.; Baker, Erin
Introduction: Polycyclic aromatic hydrocarbons (PAHs) are complex environmental toxicants; exposure to them has been linked to adverse health outcomes including cancer, as well as diseases of the skin, liver, and immune system. Based on an ongoing community engagement partnership with stakeholder groups and residents, we conducted a small longitudinal study to assess domestic exposure to PAHs among residents of Manchester, an environmental justice neighborhood located in the East End of Houston, TX. Methods: In December, 2016, we used fiber wipes to collect samples of household dust from 25 homes in Manchester. Following Hurricane Harvey, in September 2017, we revisited 24more » of the 25 homes to collect soil samples from the front yards of the same homes. Wipes and soil were analyzed for the presence of PAHs using gas chromatography–mass spectrometry (GC-MS) methods. Principle component analysis plots, heatmaps, and PAH ratios were used to compare pre- and post-Hurricane Harvey samples. Results: While direct comparison is difficult, we present three methods for comparing PAHs found in pre-hurricane fiber wipes and post-hurricane soil samples. The methods demonstrate that the PAHs found before and after Hurricane Harvey are likely from similar sources and that those sources are most likely to be associated with combustion. We also found evidence of redistribution of PAHs due to extreme flooding associated with Hurricane Harvey. Discussion: Residents of the Manchester neighborhood of Houston, TX, are exposed to a range of PAHs in household dust and outdoor soil. While difficult to compare directly, we were able to use several methods to assess detected concentrations, changes in site-specific PAH allocations, and PAH origination. Additional research is needed to identify specific sources of domestic PAH exposure in these communities and continued work involving community members and policy makers should aim to develop interventions to reduce domestic exposure to and prevent negative health outcomes from PAHs.« less
Horney, Jennifer A; Casillas, Gaston A; Baker, Erin; Stone, Kahler W; Kirsch, Katie R; Camargo, Krisa; Wade, Terry L; McDonald, Thomas J
2018-01-01
Polycyclic aromatic hydrocarbons (PAHs) are complex environmental toxicants. Exposure to them has been linked to adverse health outcomes including cancer, as well as diseases of the skin, liver, and immune system. Based on an ongoing community engagement partnership with stakeholder groups and residents, we conducted a small longitudinal study to assess domestic exposure to PAHs among residents of Manchester, an environmental justice neighborhood located in the East End of Houston, TX. In December, 2016, we used fiber wipes to collect samples of household dust from 25 homes in Manchester. Following Hurricane Harvey, in September 2017, we revisited 24 of the 25 homes to collect soil samples from the front yards of the same homes. Wipes and soil were analyzed for the presence of PAHs using gas chromatography-mass spectrometry (GC-MS) methods. Principal component analysis plots, heatmaps, and PAH ratios were used to compare pre- and post-Hurricane Harvey samples. While direct comparison is not possible, we present three methods for comparing PAHs found in pre-hurricane fiber wipes and post-hurricane soil samples. The methods demonstrate that the PAHs found before and after Hurricane Harvey are likely from similar sources and that those sources are most likely to be associated with combustion. We also found evidence of redistribution of PAHs due to extreme flooding associated with Hurricane Harvey. Residents of the Manchester neighborhood of Houston, TX, are exposed to a range of PAHs in household dust and outdoor soil. While it was not possible to compare directly, we were able to use several methods to assess detected concentrations, changes in site-specific PAH allocations, and PAH origination. Additional research is needed to identify specific sources of domestic PAH exposure in these communities and continued work involving community members and policy makers should aim to develop interventions to reduce domestic exposure to and prevent negative health outcomes from PAHs.
NASA Astrophysics Data System (ADS)
Pingitore, N. E.; Clague, J.; Amaya, M. A.
2006-12-01
Understanding the interplay of indoor and outdoor sources of lead in an urban setting is one foundation in establishing risk for lead exposure in children in our cities. A household may be the source for lead contamination due to the deterioration of interior lead-based paint, or a sink if lead particles are tracked or blown into the home from such potential ambient sources as yard soil or urban street dust. In addressing this issue, X-Ray Absorption Spectroscopy (XAS) presents the opportunity to directly and quantitatively speciate lead at low concentrations in bulk samples. We performed XAS analyses on dust wipes from window sills or floors from 8 houses that exceeded Federal standards for lead in dust. We entered these data into a Principal Components Analysis (PCA) that also included El Paso environmental samples: lead-based paints, soils, and airborne particulate matter. A simple two-component mixing system accounted for more than 95% of the variance of this data set. Paint and lead oxide appear to be the principal components, with all the samples falling in a compositional range from pure paint to 75% paint, 25% lead oxide. Note that several different lead compounds are possible constituents of a given lead-based paint. The paints spread from one end out along perhaps a fifth of the range of the compositional axis, followed closely, but not overlapped, by the soil samples, which covered the remainder of the compositional range. Two of the dust wipes plotted within the paint range, and the remaining 6 dust wipes plotted randomly through the soil range. Samples of airborne particulate matter plotted in both the paint and soil ranges. These observations suggest that the lead on most of the dust wipes originated outside the house, probably from deteriorated exterior lead-based paint deposited in adjacent yards. This paint mixed with lead oxide present in the soil and entered the houses by the airborne route. The probable source of the oxide in the soil is former airborne deposition of automobile exhaust from leaded gasoline (lead halides quickly react to form oxide). The dust wipes that fall within the compositional range of the paints may have originated from deterioration of interior paint. The XAS findings are consistent with our tests of several hundred houses in El Paso: most of the wipes that exceeded Federal lead standards came from houses in the oldest neighborhoods of the city, where lead paint is still present. X-Ray absorption spectroscopy experiments were conducted at the Stanford Synchrotron Radiation Laboratory on beam lines 7-3 and 10-2. Spectra were collected at the Pb L-III absorption edge in fluorescence mode using a 13-element or a 30-element Ge solid-state detector. This publication was made possible by grant numbers 1RO1-ES11367 and 1 S11 ES013339-01A1 from the National Institute of Environmental Health Sciences (NIEHS), NIH. Its contents are solely the responsibility of the authors and do not necessarily represent the official views of the NIEHS, NIH.
Evaluation of standardized sample collection, packaging, and ...
Journal Sample collection procedures and primary receptacle (sample container and bag) decontamination methods should prevent contaminant transfer between contaminated and non-contaminated surfaces and areas during bio-incident operations. Cross-contamination of personnel, equipment, or sample containers may result in the exfiltration of biological agent from the exclusion (hot) zone and have unintended negative consequences on response resources, activities and outcomes. The current study was designed to: (1) evaluate currently recommended sample collection and packaging procedures to identify procedural steps that may increase the likelihood of spore exfiltration or contaminant transfer; (2) evaluate the efficacy of currently recommended primary receptacle decontamination procedures; and (3) evaluate the efficacy of outer packaging decontamination methods. Wet- and dry-deposited fluorescent tracer powder was used in contaminant transfer tests to qualitatively evaluate the currently-recommended sample collection procedures. Bacillus atrophaeus spores, a surrogate for Bacillus anthracis, were used to evaluate the efficacy of spray- and wipe-based decontamination procedures.
Kiffmeyer, Thekla K; Tuerk, Jochen; Hahn, Moritz; Stuetzer, Hartmut; Hadtstein, Claudia; Heinemann, André; Eickmann, Udo
2013-05-01
A large-scale study was carried out in order to determine the contamination level of antineoplastic drugs in pharmacies and to investigate the suitability and effects of wipe sample monitoring at regular intervals. A specific study design was developed. The 130 participating pharmacies were divided into a study and a control group, carrying out five and two wipe sampling cycles, respectively. The work practice was analyzed using questionnaires to identify factors that influence the contamination level. From 1269 wipe samples, 774 (61%) were contaminated with at least one of the analyzed cytotoxic drugs: cyclophosphamide, docetaxel, etoposide, 5-fluorouracil, gemcitabine, ifosfamide, methotrexate, and paclitaxel. A significant decrease of the contamination with cyclophosphamide and 5-fluorouracil was observed in the study group. The Monitoring-Effect Study of Wipe Sampling in Pharmacies method has proven to be a reliable and affordable tool for contamination control. Based on the 90th percentile of the contamination values, a substance-independent performance-based guidance value of 0.1ng cm(-2) has been derived.
Indoor air, surface wipes (floors, table tops and window sills) and floor dust samples were collected at multiple locations within 11 occupied and 2 unoccupied homes both prior to and following lawn application of the herbicide 2,4-D. Residue measurements were made over period...
NASA Astrophysics Data System (ADS)
Edwards, Nicholas W. M.; Best, Emma L.; Connell, Simon D.; Goswami, Parikshit; Carr, Chris M.; Wilcox, Mark H.; Russell, Stephen J.
2017-12-01
Healthcare associated infections (HCAIs) are responsible for substantial patient morbidity, mortality and economic cost. Infection control strategies for reducing rates of transmission include the use of nonwoven wipes to remove pathogenic bacteria from frequently touched surfaces. Wiping is a dynamic process that involves physicochemical mechanisms to detach and transfer bacteria to fibre surfaces within the wipe. The purpose of this study was to determine the extent to which systematic changes in fibre surface energy and nano-roughness influence removal of bacteria from an abiotic polymer surface in dry wiping conditions, without liquid detergents or disinfectants. Nonwoven wipe substrates composed of two commonly used fibre types, lyocell (cellulosic) and polypropylene, with different surface energies and nano-roughnesses, were manufactured using pilot-scale nonwoven facilities to produce samples of comparable structure and dimensional properties. The surface energy and nano-roughness of some lyocell substrates were further adjusted by either oxygen (O2) or hexafluoroethane (C2F6) gas plasma treatment. Static adpression wiping of an inoculated surface under dry conditions produced removal efficiencies of between 9.4% and 15.7%, with no significant difference (p < 0.05) in the relative removal efficiencies of Escherichia coli, Staphylococcus aureus or Enterococcus faecalis. However, dynamic wiping markedly increased peak wiping efficiencies to over 50%, with a minimum increase in removal efficiency of 12.5% and a maximum increase in removal efficiency of 37.9% (all significant at p < 0.05) compared with static wiping, depending on fibre type and bacterium. In dry, dynamic wiping conditions, nonwoven wipe substrates with a surface energy closest to that of the contaminated surface produced the highest E. coli removal efficiency, while the associated increase in fibre nano-roughness abrogated this trend with S. aureus and E. faecalis.
Hammel, Stephanie C.; Hoffman, Kate; Webster, Thomas F.; Anderson, Kim A.; Stapleton, Heather M.
2016-01-01
Organophosphate flame retardants (PFRs) are widely used as replacements for polybrominated diphenyl ethers in consumer products. With high detection in indoor environments and increasing toxicological evidence suggesting a potential for adverse health effects, there is a growing need for reliable exposure metrics to examine individual exposures to PFRs. Silicone wristbands have been used as passive air samplers for quantifying exposure in the general population and occupational exposure to polycyclic aromatic hydrocarbons. Here we investigated the utility of silicone wristbands in measuring exposure and internal dose of PFRs through measurement of urinary metabolite concentrations. Wristbands were also compared to hand wipes as metrics of exposure. Participants wore wristbands for five consecutive days and collected first morning void urine samples on three alternating days. Urine samples were pooled across the three days and analyzed for metabolites of the following PFRs: tris(1,3-dichloroisopropyl) phosphate (TDCIPP), tris(1-chloro-2-isopropyl) phosphate (TCIPP), triphenyl phosphate (TPHP), and mono-substituted isopropylated triaryl phosphate (mono-ITP). All four PFRs and their urinary metabolites were ubiquitously detected. Correlations between TDCIPP and TCIPP and their corresponding urinary metabolites were highly significant on the wristbands (rs= 0.5-0.65, p<0.001), which suggest that wristbands can serve as strong predictors of cumulative, five-day exposure and may be an improved metric compared to hand wipes. PMID:26975559
Kawasaki, Kazuo; Horikawa, Keiji; Sakai, Hideo
2017-04-01
Magnetic biomonitoring techniques and in situ topsoil magnetic susceptibility measurements have been shown to be rapid, cost-effective, and useful methods for investigating roadside pollution. However, combustible vegetation in samples makes it very difficult to use them in high-temperature magnetic experiments although the thermal alteration of spontaneous magnetization is a fundamental magnetic property and can be used to identify reliably the magnetic minerals. Here, we report the first magnetic biomonitoring results of dust deposited on plant leaves along the Tateyama-Kurobe Alpine route at the highly protected Midagahara wetland areas of Mt. Tateyama in Toyama, Japan. In-field magnetic susceptibility from 15 sites (161 points) shows higher susceptibilities near the roadside. Dust deposited on the leaves of Sasa kurilensis, or dwarf bamboo, has been wiped off at 12 sites (64 samples) with a commercial ethanol wipe sheet or silica wool damped in ethanol and subjected to rock magnetic analyses. Thermomagnetic remanence curves and low-temperature behaviors for samples collected near the roadside using silica wool show clearly that the main magnetic mineral in the dust is partially oxidized magnetite. Further, detailed rock magnetic analyses and elemental analyses of leaves in the study area indicate that (a) the magnetic mineralogy on leaves' surface is consistent throughout the study area and (b) higher saturation isothermal remanent magnetization intensities as well as higher concentrations of Pb, Fe, Cr, and Y are observed near the roadside, i.e., the closer to the roadside, the more anthropogenic materials, including partially oxidized magnetite, are present. Also, microscopic observations show the lack of spherical grains, indicating that dust on the roadside leaves is derived from passing vehicle rather than industrial process. Both rock magnetic and geochemical results show that S. kurilensis would be an excellent candidate for investigating air pollution. Also, the proposed wiping-off method of collecting dust from plant surfaces is an effective non-destructive method that can be applied even in highly restricted collection areas, because detailed magnetic mineralogy, including superparamagnetic minerals, could be determined with the use of silica wool for use in both high- and low-temperature experiments.
Saha, Avinandan; Botha, Stefan Louis; Weaving, Paul; Satta, Giovanni
2016-11-01
Peracetic acid sporicidal wipes have been shown to be an effective disinfectant, but in controlled test environments. Their high cost may restrict use. This pilot study investigated the efficacy and compared the costs of routine universal use of peracetic acid sporicidal wipes versus sporicidal quaternary ammonium compound and alcohol wipes in the disinfection of a hospital environment. The routine universal use of peracetic acid wipes (Clinell Sporicidal; GAMA Healthcare Ltd, London, UK) was allocated to a study ward, whereas the control ward continued with the use of quaternary ammonium compound wipes (Tuffie 5; Vernacare, Bolton, UK) and alcohol wipes (PDI Sani-Cloth 70; PDI, Flint, UK). Twenty high-touch areas in the 2 wards were sampled for the presence of indicator organisms. The weekly detection rates of indicator organisms and weekly healthcare associated infection (HCAI) rates in the 2 wards were compared and examined for decreasing trends over the trial period. The detection rates of indicator organisms and HCAI rates were not significantly different in the 2 wards, and did not decrease significantly over the trial period. However, the peracetic acid wipes seem to be more effective against gram-negative organisms but at a significantly higher cost. Further prospective studies are needed to assess the cost-effectiveness of peracetic acid wipes. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
Willison, Stuart A
2012-12-28
Degradation products arising from nitrogen mustard chemical warfare agent were deposited on common urban surfaces and determined via surface wiping, wipe extraction, and liquid chromatography–tandem mass spectrometry detection. Wipes investigated included cotton gauze, glass fiber filter, non-woven polyester fiber and filter paper, and surfaces included several porous (vinyl tile, painted drywall, wood) and mostly non-porous (laminate, galvanized steel, glass) surfaces. Wipe extracts were analyzed by ultra-high pressure liquid chromatography–tandem mass spectrometry (UPLC–MS/MS) and compared with high performance liquid chromatography–tandem mass spectrometry (HPLC–MS/MS) results. An evaluation of both techniques suggests UPLC–MS/MS provides a quick and sensitive analysis of targeted degradation products in addition to being nearly four times faster than a single HPLC run, allowing for greater throughput during a wide-spread release concerning large-scale contamination and subsequent remediation events. Based on the overall performance of all tested wipes, filter paper wipes were selected over other wipes because they did not contain interferences or native species (TEA and DEA) associated with the target analytes, resulting in high percent recoveries and low background levels during sample analysis. Other wipes, including cotton gauze, would require a pre-cleaning step due to the presence of large quantities of native species or interferences of the targeted analytes. Percent recoveries obtained from a laminate surface were 47–99% for all nitrogen mustard degradation products. The resulting detection limits achieved from wipes were 0.2 ng/cm(2) for triethanolamine (TEA), 0.03 ng/cm(2) for N-ethyldiethanolamine (EDEA), 0.1 ng/cm(2) for N-methyldiethanolamine (MDEA), and 0.1 ng/cm(2) for diethanolamine (DEA).
Surface Analysis of Nerve Agent Degradation Products by ...
Report This sampling and analytical procedure was developed and applied by a single laboratory to investigate nerve agent degradation products, which may persist at a contaminated site, via surface wiping followed by analytical characterization. The performance data presented demonstrate the fitness-for-purpose regarding surface analysis in that single laboratory. Surfaces (laminate, glass, galvanized steel, vinyl tile, painted drywall and treated wood) were wiped with cotton gauze wipes, sonicated, extracted with distilled water, and filtered. Samples were analyzed with direct injection electrospray ionization liquid chromatography tandem mass spectrometry (ESI-LC/MS/MS) without derivatization. Detection limit data were generated for all analytes of interest on a laminate surface. Accuracy and precision data were generated from each surface fortified with these analytes.
Morgan, Marsha K; Nash, Maliha; Barr, Dana Boyd; Starr, James M; Scott Clifton, M; Sobus, Jon R
2018-03-01
Bisphenol A (BPA) is commonly manufactured to make polycarbonate plastics and epoxy resins for use in consumer products and packaged goods. BPA has been found in several different types of environmental media (e.g., food, dust, and air). Many cross-sectional studies have frequently detected BPA concentrations in adult urine samples. However, limited data are available on the temporal variability and important predictors of urinary BPA concentrations in adults. In this work, the major objectives were to: 1) quantify BPA levels in duplicate-diet solid food, drinking water, hard floor surface wipe, and urine samples (first-morning void [FMV], bedtime, and 24-h) collected from adults over a six-week monitoring period; 2) determine the temporal variability of urinary BPA levels using concentration, specific gravity (SG) adjusted, creatinine (CR) adjusted, and excretion rate values, and; 3) examine associations between available study factors and urinary BPA concentrations. In 2009-2011, a convenience sample of 50 adults was recruited from residential settings in North Carolina. The participants completed diaries and collected samples during weeks 1, 2, and/or 6 of a six-week monitoring period. BPA was detected in 38%, 4%, and 99% of the solid food (n=775), drinking water (n=50), and surface wipe samples (n=138), respectively. Total BPA (free plus conjugated) was detected in 98% of the 2477 urine samples. Median urinary BPA levels were 2.07ng/mL, 2.20ng/mL-SG, 2.29ng/mg, and 2.31ng/min for concentration, SG-adjusted, CR-adjusted, and excretion rate values, respectively. The intraclass correlation coefficient (ICC) estimates for BPA showed poor reproducibility (≤0.35) for all urine sample types and methods over a day, week, and six weeks. CR-adjusted bedtime voids collected over six-weeks required the fewest, realistic number of samples (n=11) to obtain a reliable biomarker estimate (ICC=0.80). Results of linear mixed-effects models showed that sex, race, season, and CR-level were all significant predictors (p<0.05) of the adults' urinary BPA concentrations. BPA levels in the solid food and surface wipe samples did not contribute significantly to the participants' urinary BPA concentrations. However, a significant positive relationship was observed between solid food intake and urine-based estimates of BPA dose, when aggregated over 24-h periods. Ingestion of BPA via solid food explained only about 20% of the total dose (at the median of the dose distribution), suggesting that these adults were likely exposed to other major unknown (non-dietary) sources of BPA in their everyday environments. Published by Elsevier Ltd.
Dermal exposure studies incorporating urinary biomarker measurements are complicated because dermal sampling may intercept or remove the target chemical before it is absorbed. A hand wipe subsampling method has been developed using polyurethane foam-tipped (PUF) swabs to minim...
Exposure to organophosphate flame retardants of hotel room attendants in Wuhan City, China.
Tao, Yun; Shang, Yinzhu; Li, Jing; Feng, Jingwen; He, Zhenyu; Covaci, Adrian; Wang, Peng; Luo, Jing; Mao, Xiang; Shi, Bin; Hu, Liqin; Luo, Dan; Mei, Surong
2018-05-01
Indoor environments provide sources of exposure to organophosphate flame retardants (PFRs), which are artificially synthesized fire-protecting agents used as additives in interior products. As public spaces, hotels are required to meet stricter fire-precaution criteria. As such, room attendants may be exposed to higher levels of PFRs. Our goal was to characterize the exposure of hotel room attendants to PFRs by measuring metabolites in their urine and the corresponding parent PFRs in dust and hand-wipes collected from 27 hotels located in Wuhan City, China. The exposure of the attendants was found to be omnipresent: urinary metabolites of PFRs, such as DPHP (diphenyl phosphate), BDCIPP (bis(1,3-dichloro-2-propyl) phosphate), and DoCP (di-o-cresyl phosphate) & DpCP (di-p-cresyl phosphate) were detected with high frequency (87%, 79% and 87%, respectively). We observed that metabolites in post-shift urine were consistently present at higher levels than those in the first morning voids (p < 0.05 for BDCIPP and DPHP). Regarding external exposure, 10 PFRs were determined in both dust samples and hand-wipes, with TCIPP (tris(2-chloroisopropyl) phosphate) being the most abundant compound in both matrices. The levels of PFRs in hand-wipes and dust samples were not correlated. PFRs in dust and their corresponding urinary metabolites were not significantly correlated, while a moderate significant correlation of TDCIPP (tris(1,3-dichloro-2-propyl) phosphate) in hand-wipes and its urinary metabolite, BDCIPP, was observed in both morning void samples (p = 0.01) and post-shift urine (p = 0.002). Moreover, we found that participants from high-rise buildings (defined as > 7 stories) had significantly higher BDCIPP and DPHP concentrations than those from low-rise buildings. A possible reason is that high-rise buildings may use high-grade fireproof building materials to meet stricter fire restrictions. Overall, these results indicate that PFRs exposure in hotels is a contributor to the personal exposure of hotel room attendants. Copyright © 2018 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lopez, Tammy Ann
Technical Area-18 (TA-18), also known as Pajarito Site, is located on Los Alamos National Laboratory property and has historic buildings that will be included in the Manhattan Project National Historic Park. Characterization studies of metal contamination were needed in two of the four buildings that are on the historic registry in this area, a “battleship” bunker building (TA-18-0002) and the Pond cabin (TA-18-0029). However, these two buildings have been exposed to the elements, are decades old, and have porous and rough surfaces (wood and concrete). Due to these conditions, it was questioned whether standard wipe sampling would be adequate tomore » detect surface dust metal contamination in these buildings. Thus, micro-vacuum and surface wet wipe sampling techniques were performed side-by-side at both buildings and results were compared statistically. A two-tail paired t-test revealed that the micro-vacuum and wet wipe techniques were statistically different for both buildings. Further mathematical analysis revealed that the wet wipe technique picked up more metals from the surface than the microvacuum technique. Wet wipes revealed concentrations of beryllium and lead above internal housekeeping limits; however, using an yttrium normalization method with linear regression analysis between beryllium and yttrium revealed a correlation indicating that the beryllium levels were likely due to background and not operational contamination. PPE and administrative controls were implemented for National Park Service (NPS) and Department of Energy (DOE) tours as a result of this study. Overall, this study indicates that the micro-vacuum technique may not be an efficient technique to sample for metal dust contamination.« less
The purpose of this SOP is to describe the acid digestion of soil, house dust, air filter, and surface or dermal wipe samples for analysis using inductively coupled plasma atomic emissions spectrometry (ICP-AES) and/or graphite furnace atomic absorption spectrometry (GFAAS) or fl...
Forensic collection of trace chemicals from diverse surfaces with strippable coatings.
Jakubowski, Michael J; Beltis, Kevin J; Drennan, Paul M; Pindzola, Bradford A
2013-11-07
Surface sampling for chemical analysis plays a vital role in environmental monitoring, industrial hygiene, homeland security and forensics. The standard surface sampling tool, a simple cotton gauze pad, is failing to meet the needs of the community as analytical techniques become more sensitive and the variety of analytes increases. In previous work, we demonstrated the efficacy of non-destructive, conformal, spray-on strippable coatings for chemical collection from simple glass surfaces. Here we expand that work by presenting chemical collection at a low spiking level (0.1 g m(-2)) from a diverse array of common surfaces - painted metal, engineering plastics, painted wallboard and concrete - using strippable coatings. The collection efficiency of the strippable coatings is compared to and far exceeds gauze pads. Collection from concrete, a particular challenge for wipes like gauze, averaged 73% over eight chemically diverse compounds for the strippable coatings whereas gauze averaged 10%.
Dust: a metric for use in residential and building exposure assessment and source characterization.
Lioy, Paul J; Freeman, Natalie C G; Millette, James R
2002-01-01
In this review, we examine house dust and residential soil and their use for identifying sources and the quantifying levels of toxicants for the estimation of exposure. We answer critical questions that focus on the selection of samples or sampling strategies for collection and discuss areas of uncertainty and gaps in knowledge. We discuss the evolution of dust sampling with a special emphasis on work conducted after the publication of the 1992 review by McArthur [Appl Occup Environ Hyg 7(9):599-606 (1992)]. The approaches to sampling dust examined include surface wipe sampling, vacuum sampling, and other sampling approaches, including attic sampling. The metrics of presentation of results for toxicants in dust surface loading (micrograms per square centimeter) or surface concentration (micrograms per gram) are discussed. We evaluate these metrics in terms of how the information can be used in source characterization and in exposure characterization. We discuss the types of companion information on source use and household or personal activity patterns required to assess the significance of the dust exposure. The status and needs for wipe samplers, surface samplers, and vacuum samplers are summarized with some discussion on the strengths and weaknesses of each type of sampler. We also discuss needs for research and development and the current status of standardization. Case studies are provided to illustrate the use of house dust and residential soil in source characterization, forensic analyses, or human exposure assessment. PMID:12361921
Dust: a metric for use in residential and building exposure assessment and source characterization.
Lioy, Paul J; Freeman, Natalie C G; Millette, James R
2002-10-01
In this review, we examine house dust and residential soil and their use for identifying sources and the quantifying levels of toxicants for the estimation of exposure. We answer critical questions that focus on the selection of samples or sampling strategies for collection and discuss areas of uncertainty and gaps in knowledge. We discuss the evolution of dust sampling with a special emphasis on work conducted after the publication of the 1992 review by McArthur [Appl Occup Environ Hyg 7(9):599-606 (1992)]. The approaches to sampling dust examined include surface wipe sampling, vacuum sampling, and other sampling approaches, including attic sampling. The metrics of presentation of results for toxicants in dust surface loading (micrograms per square centimeter) or surface concentration (micrograms per gram) are discussed. We evaluate these metrics in terms of how the information can be used in source characterization and in exposure characterization. We discuss the types of companion information on source use and household or personal activity patterns required to assess the significance of the dust exposure. The status and needs for wipe samplers, surface samplers, and vacuum samplers are summarized with some discussion on the strengths and weaknesses of each type of sampler. We also discuss needs for research and development and the current status of standardization. Case studies are provided to illustrate the use of house dust and residential soil in source characterization, forensic analyses, or human exposure assessment.
Estimating Dermal Transfer of Copper Particles from the ...
Lumber pressure-treated with micronized copper was examined for the release of copper and copper micro/nanoparticles using a surface wipe method to simulate dermal transfer. In 2003, the wood industry began replacing CCA treated lumber products for residential use with copper based formulations. Micronized copper (nano to micron sized particles) has become the preferred treatment formulation. There is a lack of information on the release of copper, the fate of the particles during dermal contact, and the copper exposure level to children from hand-to-mouth transfer. For the current study, three treated lumber products, two micronized copper and one ionic copper, were purchased from commercial retailers. The boards were left to weather outdoors for approximately 1 year. Over the year time period, hand wipe samples were collected periodically to determine copper transfer from the wood surfaces. The two micronized formulations and the ionic formulation released similar levels of total copper. The amount of copper released was high initially, but decreased to a constant level (~1.5 mg m-2) after the first month of outdoor exposure. Copper particles were identified on the sampling cloths during the first two months of the experiment, after which the levels of copper were insufficient to collect interpretable data. After 1 month, the particles exhibited minimal changes in shape and size. At the end of 2-months, significant deterioration of the particles was
Wu, Xiangmei May; Bennett, Deborah H; Moran, Rebecca E; Sjödin, Andreas; Jones, Richard S; Tancredi, Daniel J; Tulve, Nicolle S; Clifton, Matthew Scott; Colón, Maribel; Weathers, Walter; Hertz-Picciotto, Irva
2015-03-14
Polybrominated diphenyl ethers (PBDEs) are used as flame retardants in many household items. Given concerns over their potential adverse health effects, we identified predictors and evaluated temporal changes of PBDE serum concentrations. PBDE serum concentrations were measured in young children (2-8 years old; N = 67), parents of young children (<55 years old; N = 90), and older adults (≥55 years old; N = 59) in California, with concurrent floor wipe samples collected in participants' homes in 2008-2009. We also measured serum concentrations one year later in a subset of children (N = 19) and parents (N = 42). PBDE serum concentrations in children were significantly higher than in adults. Floor wipe concentration is a significant predictor of serum BDE-47, 99, 100 and 154. Positive associations were observed between the intake frequency of canned meat and serum concentrations of BDE-47, 99 and 154, between canned meat entrees and BDE-154 and 209, as well as between tuna and white fish and BDE-153. The model with the floor wipe concentration and food intake frequencies explained up to 40% of the mean square prediction error of some congeners. Lower home values and renting (vs. owning) a home were associated with higher serum concentrations of BDE-47, 99 and 100. Serum concentrations measured one year apart were strongly correlated as expected (r = 0.70-0.97) with a slight decreasing trend. Floor wipe concentration, food intake frequency, and housing characteristics can explain 12-40% of the prediction error of PBDE serum concentrations. Decreasing temporal trends should be considered when characterizing long-term exposure.
Xie, Mingjie; Wu, Yaoxing; Little, John C; Marr, Linsey C
2016-01-01
This work focuses on the mass content of plasticizers in children's backpacks and toys, and their mass transfer from product surfaces to cotton wipes. The mass content of plasticizers in six backpacks and seven toys was measured by extracting them in tetrahydrofuran. Bis(2-ethylhexyl) terephthalate (DEHT) was the most common plasticizer, dominating the composition of plasticizers in four backpacks (average mass content in product polyvinyl chloride, 5.38 ± 1.98%-25.5 ± 3.54%) and six plastic toys (8.17 ± 1.85%-21.2 ± 1.11%). The surface of each product was wiped with three dry and three wet (by isopropanol) cotton wipes, so as to evaluate the mass transfer of plasticizers to clothing and human skin, respectively. DEHT was the most common plasticizer detected on wipe samples. There were strong correlations (backpacks r=0.90; plastic toys r=0.96) between average mass transfer of DEHT to wet wipes and its average mass content in the product. The mass transfers of the five dominant plasticizers in one backpack to both dry and wet wipes were also correlated (both r=1.00) with their mass contents. These results suggest that the mass transfer of plasticizers from products to clothing or human skin is strongly associated with their mass content.
Evaluation of residual uranium contamination in the dirt floor of an abandoned metal rolling mill.
Glassford, Eric; Spitz, Henry; Lobaugh, Megan; Spitler, Grant; Succop, Paul; Rice, Carol
2013-02-01
A single, large, bulk sample of uranium-contaminated material from the dirt floor of an abandoned metal rolling mill was separated into different types and sizes of aliquots to simulate samples that would be collected during site remediation. The facility rolled approximately 11,000 tons of hot-forged ingots of uranium metal approximately 60 y ago, and it has not been used since that time. Thirty small mass (≈ 0.7 g) and 15 large mass (≈ 70 g) samples were prepared from the heterogeneously contaminated bulk material to determine how measurements of the uranium contamination vary with sample size. Aliquots of bulk material were also resuspended in an exposure chamber to produce six samples of respirable particles that were obtained using a cascade impactor. Samples of removable surface contamination were collected by wiping 100 cm of the interior surfaces of the exposure chamber with 47-mm-diameter fiber filters. Uranium contamination in each of the samples was measured directly using high-resolution gamma ray spectrometry. As expected, results for isotopic uranium (i.e., U and U) measured with the large-mass and small-mass samples are significantly different (p < 0.001), and the coefficient of variation (COV) for the small-mass samples was greater than for the large-mass samples. The uranium isotopic concentrations measured in the air and on the wipe samples were not significantly different and were also not significantly different (p > 0.05) from results for the large- or small-mass samples. Large-mass samples are more reliable for characterizing heterogeneously distributed radiological contamination than small-mass samples since they exhibit the least variation compared to the mean. Thus, samples should be sufficiently large in mass to insure that the results are truly representative of the heterogeneously distributed uranium contamination present at the facility. Monitoring exposure of workers and the public as a result of uranium contamination resuspended during site remediation should be evaluated using samples of sufficient size and type to accommodate the heterogeneous distribution of uranium in the bulk material.
Investigation of the Persistence of Nerve Agent Degradation ...
Journal Article The persistence of chemical warfare nerve agent degradation analytes on surfaces is important for reasons ranging from indicating the presence of nerve agent on that surface to environmental restoration of a site after nerve agent release. This study investigates the persistence of several chemical warfare nerve agent degradation analytes on a number of indoor surfaces and presents an approach for wipe sampling of surfaces, followed by wipe extraction and liquid chromatography-tandem mass spectrometry detection. Multiple commercially available wipe materials were investigated to determine optimal wipe recoveries. Tested surfaces, including several porous/permeable and largely nonporous/impermeable surfaces, were investigated to determine recoveries from these indoor surface materials. Wipe extracts were analyzed by ultra-high performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) and compared with high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) results. UPLC provides a sensitive separation of targeted degradation analytes in addition to being nearly four times faster than HPLC, allowing for greater throughput during a widespread release concerning large-scale contamination and subsequent remediation events. Percent recoveries from nonporous/impermeable surfaces were 60-103% for isopropyl methylphosphonate (IMPA), 61-91 % for ethyl methylphosphonate (EMPA), and 60-98% for pinacolyl methylphosphona
Huitema, A. D. R.; Bakker, E. N.; Douma, J. W.; Schimmel, K. J. M.; van Weringh, G.; de Wolf, P. J.; Schellens, J. H. M.; Beijnen, J. H.
2007-01-01
Objective: To develop, validate, and apply a method for the determination of platinum contamination, originating from cisplatinum, oxaliplatinum, and carboplatinum. Methods: Inductively coupled plasma mass spectrometry (ICP-MS) was used to determine platinum in wipe samples. The sampling procedure and the analytical conditions were optimised and the assay was validated. The method was applied to measure surface contamination in seven Dutch hospital pharmacies. Results: The developed method allowed reproducible quantification of 0.50 ng l−1 platinum (5 pg/wipe sample). Recoveries for stainless steel and linoleum surfaces ranged between 50.4 and 81.4% for the different platinum compounds tested. Platinum contamination was reported in 88% of the wipe samples. Although a substantial variation in surface contamination of the pharmacies was noticed, in most pharmacies, the laminar-airflow (LAF) hoods, the floor in front of the LAF hoods, door handles, and handles of service hatches showed positive results. This demonstrates that contamination is spread throughout the preparation rooms. Conclusion: We developed and validated an ultra sensitive and reliable ICP-MS method for the determination of platinum in surface samples. Surface contamination with platinum was observed in all hospital pharmacies sampled. The interpretation of these results is, however, complicated. PMID:17377802
Hernon-Kenny, Laura A; Behringer, Deborah L; Crenshaw, Michael D
2016-05-01
Comparison of solvent-wetted gauze with body paint, a peelable surface sampling media, for the sampling of the chemical warfare agents VX and sulfur mustard from nine surfaces was performed. The nine surfaces sampled are those typical of interior public venues and include smooth, rough, porous, and non-porous surfaces. Overall, solvent-wetted gauze (wipes) performed better for the recovery of VX from non-porous surfaces while body paint (BP) performed better for the porous surfaces. The average percent VX recoveries using wipes and BP, respectively, are: finished wood flooring, 86.2%, 71.4%; escalator handrail, 47.3%, 26.7%; stainless steel, 80.5%, 56.1%; glazed ceramic tile, 81.8%, 44.9%; ceiling tile, 1.77%, 13.1%; painted drywall 7.83%, 21.1%; smooth cement, 0.64%, 10.3%; upholstery fabric, 24.6%, 23.1%; unfinished wood flooring, 9.37%, 13.1%. Solvent-wetted gauze performed better for the recovery of sulfur mustard from three of the relatively non-porous surfaces while body paint performed better for the more porous surfaces. The average percent sulfur mustard recoveries using wipes and BP, respectively, are: finished wood flooring, 30.2%, 2.97%; escalator handrail, 4.40%, 4.09%; stainless steel, 21.2%, 3.30%; glazed ceramic tile, 49.7%, 16.7%; ceiling tile, 0.33%, 11.1%; painted drywall 2.05%, 10.6%; smooth cement, 1.20%, 35.2%; upholstery fabric, 7.63%, 6.03%; unfinished wood flooring, 0.90%, 1.74%. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Impact of Processing Method on Recovery of Bacteria from Wipes Used in Biological Surface Sampling
Olson, Nathan D.; Filliben, James J.; Morrow, Jayne B.
2012-01-01
Environmental sampling for microbiological contaminants is a key component of hygiene monitoring and risk characterization practices utilized across diverse fields of application. However, confidence in surface sampling results, both in the field and in controlled laboratory studies, has been undermined by large variation in sampling performance results. Sources of variation include controlled parameters, such as sampling materials and processing methods, which often differ among studies, as well as random and systematic errors; however, the relative contributions of these factors remain unclear. The objective of this study was to determine the relative impacts of sample processing methods, including extraction solution and physical dissociation method (vortexing and sonication), on recovery of Gram-positive (Bacillus cereus) and Gram-negative (Burkholderia thailandensis and Escherichia coli) bacteria from directly inoculated wipes. This work showed that target organism had the largest impact on extraction efficiency and recovery precision, as measured by traditional colony counts. The physical dissociation method (PDM) had negligible impact, while the effect of the extraction solution was organism dependent. Overall, however, extraction of organisms from wipes using phosphate-buffered saline with 0.04% Tween 80 (PBST) resulted in the highest mean recovery across all three organisms. The results from this study contribute to a better understanding of the factors that influence sampling performance, which is critical to the development of efficient and reliable sampling methodologies relevant to public health and biodefense. PMID:22706055
Hines, Cynthia J; Jackson, Matthew V; Christianson, Annette L; Clark, John C; Arnold, James E; Pretty, Jack R; Deddens, James A
2017-11-01
For decades, bisphenol A (BPA) has been used in making polycarbonate, epoxy, and phenolic resins and certain investment casting waxes, yet published exposure data are lacking for U.S. manufacturing workers. In 2013-2014, BPA air and hand exposures were quantified for 78 workers at six U.S. companies making BPA or BPA-based products. Exposure measures included an inhalable-fraction personal air sample on each of two consecutive work days (n = 146), pre- and end-shift hand wipe samples on the second day (n = 74 each), and surface wipe samples (n = 88). Potential determinants of BPA air and end-shift hand exposures (after natural log transformation) were assessed in univariate and multiple regression mixed models. The geometric mean (GM) BPA air concentration was 4.0 µg/m 3 (maximum 920 µg/m 3 ). The end-shift GM BPA hand level (26 µg/sample) was 10-times higher than the pre-shift level (2.6 µg/sample). BPA air and hand exposures differed significantly by industry and job. BPA air concentrations and end-shift hand levels were highest in the BPA-filled wax manufacturing/reclaim industry (GM Air = 48 µg/m 3 , GM Hand-End = 130 µg/sample) and in the job of working with molten BPA-filled wax (GM Air = 43 µg/m 3 , GM Hand-End = 180 µg/sample), and lowest in the phenolic resins industry (GM Air = 0.85 µg/m 3 , GM Hand-End = 0.43 µg/sample) and in the job of flaking phenolic resins (GM AIR = 0.62 µg/m 3 , GM Hand-End = 0.38 µg/sample). Determinants of increased BPA air concentration were industry, handling BPA containers, spilling BPA, and spending ≥50% of the shift in production areas; increasing age was associated with lower air concentrations. BPA hand exposure determinants were influenced by high values for two workers; for all other workers, tasks involving contact with BPA-containing materials and spending ≥50% of the shift in production areas were associated with increased BPA hand levels. Surface wipe BPA levels were significantly lower in eating/office areas (GM = 9.3 µg/100 cm 2 ) than in production areas (GM = 140 µg/100 cm 2 ). In conclusion, worker BPA exposure was associated with tasks and conditions affecting both inhalation and dermal exposure. The potential for BPA-related health effects among these workers is unknown.
Adé, Apolline; Chauchat, Laure; Frève, Johann-François Ouellette; Gagné, Sébastien; Caron, Nicolas; Bussières, Jean-François
2017-01-01
Background Several studies have compared cleaning procedures for decontaminating surfaces exposed to antineoplastic drugs. All of the cleaning products tested were successful in reducing most of the antineoplastic drug quantities spilled on surfaces, but none of them completely removed residual traces. Objective To assess the efficacy of various cleaning solutions for decontaminating a biological safety cabinet workbench exposed to a defined amount of cyclophosphamide. Methods In this pilot study, specific areas of 2 biological safety cabinets (class II, type B2) were deliberately contaminated with a defined quantity of cyclophosphamide (10 μg or 107 pg). Three cleaning solutions were tested: quaternary ammonium, sodium hypochlorite 0.02%, and sodium hypochlorite 2%. After cleaning, the cyclophosphamide remaining on the areas was quantified by wipe sampling. Each cleaning solution was tested 3 times, with cleaning and wipe sampling being performed 5 times for each test. Results A total of 57 wipe samples were collected and analyzed. The average recovery efficiency was 121.690% (standard deviation 5.058%). The decontamination efficacy increased with the number of successive cleaning sessions: from 98.710% after session 1 to 99.997% after session 5 for quaternary ammonium; from 97.027% to 99.997% for sodium hypochlorite 0.02%; and from 98.008% to 100% for sodium hypochlorite 2%. Five additional cleaning sessions performed after the main study (with detergent and sodium hypochlorite 2%) were effective to complete the decontamination, leaving no detectable traces of the drug. Conclusions All of the cleaning solutions reduced contamination of biological safety cabinet workbenches exposed to a defined amount of cyclophosphamide. Quaternary ammonium and sodium hypochlorite (0.02% and 2%) had mean efficacy greater than 97% for removal of the initial quantity of the drug (107 pg) after the first cleaning session. When sodium hypochlorite 2% was used, fewer cleaning sessions were required to complete decontamination. Further studies should be conducted to identify optimal cleaning strategies to fully eliminate traces of hazardous drugs. PMID:29298999
Karoly, William J; Flatley, John J; Stevenson, Ralph D; Bowers, John D
2004-12-01
Air monitoring data were collected from industrial hygiene surveys over an 8-year period in oriented strand board (OSB) mills. Personal samples were taken to evaluate potential employee exposures to MDI. Area samples were taken to determine the effectiveness of control measures used in the mills to prevent fugitive emissions of wood dust, MDI, and MDI-coated wood dust from the OSB manufacturing process. Personal sampling results (578 samples covering 11 different job categories) ranged from 0.0002-0.524 mg/m3, with a GM = 0.001 and GSD = 3.71. Area sampling results (1657 samples covering 14 stationary locations in the mills) ranged from 0.0002-2.5 mg/m3, with a GM = 0.004 and GSD = 5.52. The statistical range of the data suggests high variability. While exposures to MDI above the established limits (0.051 mg/m3, 8-hour time-weighted average, 0.2 mg/m3, ceiling) can and do occur when engineering controls are not maintained and/or proper work practices and personal protective equipment are not followed/used for certain high exposure potential tasks, the data indicate that over 97% of the personal and 92% of the area sampling results are less than 0.051 mg/m3. Wipe testing was performed to determine the presence of removable, unreacted diisocyanates (NCO functional groups)from various surfaces. Positive results were found in about 13% of the wipe tests on surfaces confined to the blender, forming line, and hopper deck process areas.
Rodrigues, Ema G.; Virji, M. Abbas; McClean, Michael D.; Weinberg, Janice; Woskie, Susan; Pepper, Lewis D.
2009-01-01
Bridge painters are exposed to lead during several job tasks performed during the workday, such as sanding, scraping, and blasting. After the Occupational Safety and Health Administration standard was passed in 1993 to control lead exposures among construction workers including bridge painters, this study was conducted among 84 bridge painters in the New England area to determine the significant predictors of blood lead levels. Lead was measured in personal air and hand wipe samples that were collected during the 2-week study period and in blood samples that were collected at the beginning and at the end of the study period. The personal air and hand wipe data as well as personal behaviors (i.e., smoking, washing, wearing a respirator) and work site conditions were analyzed as potential determinants of blood lead levels using linear mixed effects models. Our results show that the mean air lead levels over the 2-week period were the most predictive exposure measure of blood lead levels. Other individual-level significant predictors of blood lead levels included months worked on bridge painting crews, education, and personal hygiene index. Of the site-level variables investigated, having a containment facility on site was a significant predictor of blood lead levels. Our results also indicate that hand wipe lead levels were significantly associated with higher blood lead levels at the end of the study period compared with the beginning of the study period. Similarly, smoking on site and respirator fit testing were significantly associated with higher blood lead levels at the end of the study period. This study shows that several individual-level and site-level factors are associated with blood lead levels among bridge painters, including lead exposure through inhalation and possible hand-to-mouth contact, personal behaviors such as smoking on site, respirator fit testing, and work site conditions such as the use of better containment facilities. Accordingly, reduction in blood lead levels among bridge painters can be achieved by improving these workplace practices. PMID:19953411
Galea, Karen S.; McGonagle, Carolyn; Sleeuwenhoek, Anne; Todd, David; Jiménez, Araceli Sánchez
2014-01-01
Dermal exposure to drilling fluids and crude oil is an exposure route of concern. However, there have been no published studies describing sampling methods or reporting dermal exposure measurements. We describe a study that aimed to evaluate a wipe sampling method to assess dermal exposure to an oil-based drilling fluid and crude oil, as well as to investigate the feasibility of using an interception cotton glove sampler for exposure on the hands/wrists. A direct comparison of the wipe and interception methods was also completed using pigs’ trotters as a surrogate for human skin and a direct surface contact exposure scenario. Overall, acceptable recovery and sampling efficiencies were reported for both methods, and both methods had satisfactory storage stability at 1 and 7 days, although there appeared to be some loss over 14 days. The methods’ comparison study revealed significantly higher removal of both fluids from the metal surface with the glove samples compared with the wipe samples (on average 2.5 times higher). Both evaluated sampling methods were found to be suitable for assessing dermal exposure to oil-based drilling fluids and crude oil; however, the comparison study clearly illustrates that glove samplers may overestimate the amount of fluid transferred to the skin. Further comparison of the two dermal sampling methods using additional exposure situations such as immersion or deposition, as well as a field evaluation, is warranted to confirm their appropriateness and suitability in the working environment. PMID:24598941
Assessment of arsenic surface contamination in a museum anthropology department.
Gribovich, Andrey; Lacey, Steven; Franke, John; Hinkamp, David
2013-02-01
To assess potential arsenic (As) contamination of work surfaces to improve upon the control strategy at an anthropology department in a large natural history museum. Work practices were observed and control strategy reviewed to inform an occupational hygiene assessment strategy utilizing surface wipe sampling. A total of 35 sampling targets were identified, focusing on surfaces that receive high touch traffic, including workstations, artifact transport carts, and elevator buttons. Arsenic sampling and analysis were performed using reference method Occupational Safety and Health Administration ID-125G. Four of the sampling areas returned detectable levels of As, ranging from 0.052 to 0.350 μg/100 cm. Workplace observations and wipe sampling data enabled the development of recommendations to help to further reduce potential occupational exposure to As. Continuous reduction of surface contamination is prudent for known human carcinogens.
An electro-conductive organic coating for scanning electron microscopy (déjà vu)
NASA Astrophysics Data System (ADS)
Burnett, Bryan R.
2014-09-01
An organic compound, originally marketed as an antistatic, can form an extremely thin electro-conductive coating upon drying. A scanning electron microscope (SEM) application for this compound was first explored in the late 1960s. A coating of this compound eliminates the need for carbon or gold coating in some applications. It is well suited for the viewing of fabric samples and associated gunshot residue (GSR) in the SEM and makes it possible to quickly analyze fabric bullet wipe and bore wipe GSR. Fabric samples can also be examined for GSR from intermediate-range shots to estimate muzzle-target distances. Scanning
In-injection port thermal desorption for explosives trace evidence analysis.
Sigman, M E; Ma, C Y
1999-10-01
A gas chromatographic method utilizing thermal desorption of a dry surface wipe for the analysis of explosives trace chemical evidence has been developed and validated using electron capture and negative ion chemical ionization mass spectrometric detection. Thermal desorption was performed within a split/splitless injection port with minimal instrument modification. Surface-abraded Teflon tubing provided the solid support for sample collection and desorption. Performance was characterized by desorption efficiency, reproducibility, linearity of the calibration, and method detection and quantitation limits. Method validation was performed with a series of dinitrotoluenes, trinitrotoluene, two nitroester explosives, and one nitramine explosive. The method was applied to the sampling of a single piece of debris from an explosion containing trinitrotoluene.
Microvolume protein concentration determination using the NanoDrop 2000c spectrophotometer.
Desjardins, Philippe; Hansen, Joel B; Allen, Michael
2009-11-04
Traditional spectrophotometry requires placing samples into cuvettes or capillaries. This is often impractical due to the limited sample volumes often used for protein analysis. The Thermo Scientific NanoDrop 2000c Spectrophotometer solves this issue with an innovative sample retention system that holds microvolume samples between two measurement surfaces using the surface tension properties of liquids, enabling the quantification of samples in volumes as low as 0.5-2 microL. The elimination of cuvettes or capillaries allows real time changes in path length, which reduces the measurement time while greatly increasing the dynamic range of protein concentrations that can be measured. The need for dilutions is also eliminated, and preparations for sample quantification are relatively easy as the measurement surfaces can be simply wiped with laboratory wipe. This video article presents modifications to traditional protein concentration determination methods for quantification of microvolume amounts of protein using A280 absorbance readings or the BCA colorimetric assay.
40 CFR 761.312 - Compositing of samples.
Code of Federal Regulations, 2010 CFR
2010-07-01
... to composite surface wipe test samples and to use the composite measurement to represent the PCB concentration of the entire surface. Composite samples consist of more than one sample gauze extracted and... arithmetic mean of the composited samples. (a) Compositing samples from surfaces to be used or reused. For...
Galea, Karen S; McGonagle, Carolyn; Sleeuwenhoek, Anne; Todd, David; Jiménez, Araceli Sánchez
2014-06-01
Dermal exposure to drilling fluids and crude oil is an exposure route of concern. However, there have been no published studies describing sampling methods or reporting dermal exposure measurements. We describe a study that aimed to evaluate a wipe sampling method to assess dermal exposure to an oil-based drilling fluid and crude oil, as well as to investigate the feasibility of using an interception cotton glove sampler for exposure on the hands/wrists. A direct comparison of the wipe and interception methods was also completed using pigs' trotters as a surrogate for human skin and a direct surface contact exposure scenario. Overall, acceptable recovery and sampling efficiencies were reported for both methods, and both methods had satisfactory storage stability at 1 and 7 days, although there appeared to be some loss over 14 days. The methods' comparison study revealed significantly higher removal of both fluids from the metal surface with the glove samples compared with the wipe samples (on average 2.5 times higher). Both evaluated sampling methods were found to be suitable for assessing dermal exposure to oil-based drilling fluids and crude oil; however, the comparison study clearly illustrates that glove samplers may overestimate the amount of fluid transferred to the skin. Further comparison of the two dermal sampling methods using additional exposure situations such as immersion or deposition, as well as a field evaluation, is warranted to confirm their appropriateness and suitability in the working environment. © The Author 2014. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.
Evaluation of Firefighter Exposure to Wood Smoke during Training Exercises at Burn Houses.
Fernando, Sujan; Shaw, Lorraine; Shaw, Don; Gallea, Michael; VandenEnden, Lori; House, Ron; Verma, Dave K; Britz-McKibbin, Philip; McCarry, Brian E
2016-02-02
Smoke from wood-fueled fires is one of the most common hazards encountered by firefighters worldwide. Wood smoke is complex in nature and contains numerous compounds, including methoxyphenols (MPs) and polycyclic aromatic hydrocarbons (PAHs), some of which are carcinogenic. Chronic exposure to wood smoke can lead to adverse health outcomes, including respiratory infections, impaired lung function, cardiac infarctions, and cancers. At training exercises held in burn houses at four fire departments across Ontario, air samples, skin wipes, and urine specimens from a cohort of firefighters (n = 28) were collected prior to and after exposure. Wood was the primary fuel used in these training exercises. Air samples showed that MP concentrations were on average 5-fold greater than those of PAHs. Skin wipe samples acquired from multiple body sites of firefighters indicated whole-body smoke exposure. A suite of MPs (methyl-, ethyl-, and propylsyringol) and deconjugated PAH metabolites (hydroxynaphthalene, hydroxyfluorene, hydroxyphenanthrene, and their isomers) were found to be sensitive markers of smoke exposure in urine. Creatinine-normalized levels of these markers were significantly elevated (p < 0.05) in 24 h postexposure urine despite large between-subject variations that were dependent on the specific operational roles of firefighters while using personal protective equipment. This work offers deeper insight into potential health risk from smoke exposure that is needed for translation of better mitigation policies, including improved equipment to reduce direct skin absorption and standardized hygiene practices implemented at different regional fire services.
Contributions of Paint and Soil to Pb in Household Dust Wipes: An XAS Study
NASA Astrophysics Data System (ADS)
Pingitore, N. E.; Clague, J. W.; Amaya, M. A.
2010-12-01
Speciation of Pb by X-ray absorption spectroscopy (XAS) indicated that Pb compounds associated with lead-based paint accounted for perhaps half of the Pb in 24 household dust wipes collected in El Paso, Texas. Soil-derived, sorbed Pb, likely Pb-humate, was also a major Pb species in many of the dust wipes. Household dust wipes are a standard technique for evaluating health risks of Pb to children, particularly toddlers, in public and private housing. The level of Pb in the wipes does not, however, indicate whether the source of the Pb is the house itself (peeling or powdering interior or exterior paint) or external, from contaminated soil or airborne particulate matter brought into the house by wind or foot traction. Understanding the origin of Pb in household dust is important in remediation: cover the old paint or remove the yard soil. XAS speciation can assist in understanding the source of Pb in household dust. The presence of significant Pb-humate requires a soil source, and suggests the need for soil remediation. Such species of Pb as hydrocerussite, lead sulfate, lead silicate, and lead chromate can be presumed to be components of lead-based paint. These may represent interior and/or exterior paint and thus do not uniquely identify the locus of the Pb source(s). Pb L-III edge XAFS data were collected on beam lines 7-3, 10-2, and 11-2 at SSRL at typical conditions of 3 GeV field and 80-200 mA current, using Si(220) water- or liquid-nitrogen-cooled monochromator crystals. Data were collected at ambient temperature in fluorescence mode using a 13- or 30-element Ge detector with a Se 3 or 6 filter and Soller slits to reduce scattered radiation. This publication was made possible by grant numbers 1RO1-ES11367 and 1 S11 ES013339-01A1 from the National Institute of Environmental Health Sciences (NIEHS), NIH. Its contents are solely the responsibility of the authors and do not necessarily represent the official views of the NIEHS, NIH. Portions of this research were carried out at the Stanford Synchrotron Radiation Lightsource, a national user facility operated by Stanford University on behalf of the U.S. Department of Energy, Office of Basic Energy Sciences.
... insert your catheter: Wash your hands well with soap and water. Collect your supplies, including your catheter ( ... penis with Betadine (an antiseptic cleaner), a towelette, soap and water, or baby wipes the way your ...
NHEXAS PHASE I ARIZONA STUDY--QA ANALYTICAL RESULTS FOR METALS IN SPIKE SAMPLES
The Metals in Spike Samples data set contains the analytical results of measurements of up to 11 metals in 38 control samples (spikes) from 18 households. Measurements were made in spiked samples of dust, food, beverages, blood, urine, and dermal wipe residue. Spiked samples we...
Comparison of Grab, Air, and Surface Results for Radiation Site Characterization
NASA Astrophysics Data System (ADS)
Glassford, Eric Keith
2011-12-01
The use of proper sampling methods and sample types for evaluating sites believed to be contaminated with radioactive materials is necessary to avoid misrepresenting conditions at the site. This study was designed to investigate if the site characterization, based upon uranium contamination measured in different types of samples, is dependent upon the mass of the sample collected. A bulk sample of potentially contaminated interior dirt was collected from an abandoned metal processing mill that rolled uranium between 1948 and 1956. The original mill dates from 1910 and has a dirt floor. The bulk sample was a mixture of dirt, black and yellow particles of metal dust, and small fragments of natural debris. Small mass (approximately 0.75 grams (g)) and large mass (approximately 70g) grab samples were prepared from the bulk sample material to simulate collection of a "grab" type sample. Air sampling was performed by re-suspending a portion of the bulk sample material using a vibration table to simulate airborne contamination that might be present during site remediation. Additionally, samples of removable contaminated surface dust were collected on 47 mm diameter filter paper by wiping the surfaces of the exposure chamber used to resuspend the bulk material. Certified reference materials, one containing a precisely known quantity of U 3O8 and one containing a known quantity of natural uranium, were utilized to calibrate the gamma spectrometry measurement system. Non-destructive gamma spectrometry measurements were used to determine the content of uranium-235 (235U) at 185 keV and 143 keV, thorium-234 (234Th) at 63 keV, and protactinium-234m (234mPa) at 1001 keV in each sample. Measurement of natural uranium in small, 1 g samples is usually accomplished by radiochemical analysis in order to measure alpha particles emitted by 238U, 235U, and 234U. However, uranium in larger bulk samples can also be measured non-destructively using gamma spectrometry to detect the low energy photons from 234Th and 234mPa, the short-lived decay products of 238U, and 235U. Two sided t-tests and coefficient of variation were used to compare sampling types. The large grab samples had the lowest calculated coefficient of variation results for activity and atom percentage. The wipe samples had the highest calculated coefficient of variation of mean specific activity (dis/sec/g) for all three energies. The air filter samples had the highest coefficient of variation calculation for mean atom percentage, for both uranium isotopes examined. The data indicated that the large mass sample was the most effective at characterizing the rolling mill radioactive site conditions, since this would indicate which samples had the smallest variations compared to the mean. Additionally, measurement results of natural uranium in the samples indicate that the distribution of radioactive contamination at the sampling location is most likely non-homogeneous and that the size of the sample collected and analyzed must be sufficiently large to insure that the analytical results are truly representative of the activity present.
Persson, Josefin; Wang, Thanh; Hagberg, Jessika
2018-07-01
The construction of extremely airtight and energy efficient low-energy buildings is achieved by using functional building materials, such as age-resistant plastics, insulation, adhesives, and sealants. Additives such as organophosphate flame retardants (OPFRs) can be added to some of these building materials as flame retardants and plasticizers. Some OPFRs are considered persistent, bioaccumulative and toxic. Therefore, in this pilot study, the occurrence and distribution of nine OPFRs were determined for dust, air, and window wipe samples collected in newly built low-energy preschools with and without environmental certifications. Tris(1,3-dichloroisopropyl) phosphate (TDCIPP) and triphenyl phosphate (TPHP) were detected in all indoor dust samples at concentrations ranging from 0.014 to 10μg/g and 0.0069 to 79μg/g, respectively. Only six OPFRs (predominantly chlorinated OPFRs) were detected in the indoor air. All nine OPFRs were found on the window surfaces and the highest concentrations, which occurred in the reference preschool, were measured for 2-ethylhexyl diphenyl phosphate (EHDPP) (maximum concentration: 1500ng/m 2 ). Interestingly, the OPFR levels in the environmental certified low-energy preschools were lower than those in the reference preschool and the non-certified low-energy preschool, probably attributed to the usage of environmental friendly and low-emitting building materials, interior decorations, and consumer products. Copyright © 2018 Elsevier B.V. All rights reserved.
Williams, G J; Denyer, S P; Hosein, I K; Hill, D W; Maillard, J-Y
2007-12-01
We developed a three-step protocol to quantify the efficacy of disinfectant wipes, their ability to remove and prevent microbial transfer from surfaces and their overall antimicrobial activity. Meticillin-resistant (MRSA) or -susceptible (MSSA) Staphylococcus aureus (6-7 log(10)cfu) were inoculated onto stainless steel discs with or without organic load and dried. Grapefruit extract-containing test wipes and unmedicated control wipes were used. In step 1, wipes were mechanically rotated against surfaces for 10s at 60rpm, exerting a weight of 100+/-5g. Bacterial removal was assessed by transferring the steel discs to neutraliser, resuspending and counting remaining bacteria. In step 2, bacterial transfer from wipes was assessed by eight consecutive mechanical adpression transfers to agar/neutraliser plates. Step 3 was the measurement of antimicrobial activity by direct inoculation of the wipes for 10s followed by neutralisation and enumeration. Test wipes achieved a significantly higher bacterial cell removal than control wipes on all surfaces (P<0.05). The low bactericidal activity of the wipes (<1 log(10) reduction when directly inoculated) and the subsequent survival of bacteria on the wipes, however, led to repeated microbial transfer when initially high contamination levels were present. There were no differences between MRSA and MSSA in removal, transfer or antimicrobial activity. The three-step method is a useful tool for developing future guidelines to assess the ability of wipes to disinfect surfaces.
NHEXAS PHASE I ARIZONA STUDY--QA ANALYTICAL RESULTS FOR PESTICIDES IN BLANK SAMPLES
The Pesticides in Blank Samples data set contains the analytical results of measurements of up to 4 pesticides in 43 blank samples from 29 households. Measurements were made in blank samples of dust, indoor and outdoor air, food and beverages, blood, urine, and dermal wipe resid...
Clarification of Net Contents Declarations for Antimicrobial Wipe Products
EPA requirements with respect to weights on wipe product labels are described and will be applied prospectively to all wipe products. The Agency considers that these wipe products are a mixture of liquid and solid.
Microvolume Protein Concentration Determination using the NanoDrop 2000c Spectrophotometer
Desjardins, Philippe; Hansen, Joel B.; Allen, Michael
2009-01-01
Traditional spectrophotometry requires placing samples into cuvettes or capillaries. This is often impractical due to the limited sample volumes often used for protein analysis. The Thermo Scientific NanoDrop 2000c Spectrophotometer solves this issue with an innovative sample retention system that holds microvolume samples between two measurement surfaces using the surface tension properties of liquids, enabling the quantification of samples in volumes as low as 0.5-2 μL. The elimination of cuvettes or capillaries allows real time changes in path length, which reduces the measurement time while greatly increasing the dynamic range of protein concentrations that can be measured. The need for dilutions is also eliminated, and preparations for sample quantification are relatively easy as the measurement surfaces can be simply wiped with laboratory wipe. This video article presents modifications to traditional protein concentration determination methods for quantification of microvolume amounts of protein using A280 absorbance readings or the BCA colorimetric assay. PMID:19890248
U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--QA ANALYTICAL RESULTS FOR METALS IN SPIKE SAMPLES
The Metals in Spike Samples data set contains the analytical results of measurements of up to 11 metals in 15 control samples (spikes) from 11 households. Measurements were made in spiked samples of dust, food, and dermal wipe residue. Spiked samples were used to assess recover...
This method describes procedures for preparation and analysis of solid, water and wipe samples for detection and measurement of cyanide amendable to chlorination using acid digestion and spectrophotometry.
Flame retardant exposure assessment: findings from a behavioral intervention study.
Gibson, Elizabeth A; Stapleton, Heather M; Calero, Lehyla; Holmes, Darrell; Burke, Kimberly; Martinez, Rodney; Cortes, Boris; Nematollahi, Amy; Evans, David; Herbstman, Julie B
2018-06-28
Polybrominated diphenyl ethers (PBDEs) have been largely replaced by organophosphate flame retardants (OPFRs) and alternative brominated flame retardants (Alt-BFRs) to meet flammability requirements. Humans are ubiquitously exposed to some variety of flame retardants through contact with consumer products directly or through household dust. To evaluate the effectiveness of house cleaning and hand washing practices to reduce exposure to flame retardants, we measured concentrations in dermal hand wipes and urinary metabolites before and after assignment to two consecutive interventions. We selected 32 mother and child dyads from an existing cohort. This analysis focuses on mothers. Participants provided baseline measurements (urine, hand wipes, and questionnaires) and were then assigned for 1 week to either a house cleaning (including instruction on proper technique and cleaning supplies) or hand washing (including instruction on proper technique and soaps) intervention arm. For the second week, participants were assigned to the second intervention in addition to their initial assignment, thus all subjects both washed their hands and cleaned according to the intervention guidelines during week 2. We collected measurements at the end of weeks 1 and 2. We found reductions in urinary analytes after week 1 of house cleaning (BCIPHIPP and ip-DPHP), week 1 of hand washing (BCIPP, BCIPHIPP, and tbutyl-DPHP), and week 2 of combined interventions (BCIPHIPP and tbutyl-DPHP), compare to baseline. We found no significant decline in hand wipes in the entire sample but did find reductions after week 1 of house cleaning (BDE 209), week 1 of hand washing (TCEP), and week 2 of combined interventions (TDCIPP and BDE 209) in women with exposure above the median at baseline (verified through simulations). Exposure to individual flame retardants was reduced by about half, in some cases, by 1 week of increased hand washing, house cleaning to reduce dust, or combined activities.
Exposure of Firefighters to Particulates and Polycyclic Aromatic Hydrocarbons
Baxter, C. Stuart; Hoffman, Joseph D.; Knipp, Michael J.; Reponen, Tiina; Haynes, Erin N.
2015-01-01
Firefighting continues to be among the most hazardous yet least studied occupations in terms of exposures and their relationship to occupational disease. Exposures are complex, involving mixtures of particles and chemicals such as polycyclic aromatic hydrocarbons (PAHs). Adverse health effects associated with these agents include elevated incidences of coronary heart disease and several cancers. PAHs have been detected at fire scenes, and in the firehouse rest area and kitchen, routinely adjoining the truck bay, and where firefighters spend a major part of each shift. An academic-community partnership was developed with the Cincinnati Fire Department with the goal of understanding active firefighters' airborne and dermal PAH exposure. PAHs were measured in air and particulates, and number and mass concentrations, respectively, of submicron (0.02–1 μm) and PM2.5 (2.5 μm diameter and less) particles during overhaul events in two firehouses and a University of Cincinnati administrative facility as a comparison location. During overhaul firefighters evaluate partially combusted materials for re-ignition after fire extinguishment and commonly remove Self-Contained Breathing Apparatus (SCBA). Face and neck wipes were also collected at a domestic fire scene. Overhaul air samples had higher mean concentrations of PM2.5 and submicron particles than those collected in the firehouse, principally in the truck bay and kitchen. Among the 17 PAHs analyzed, only naphthalene and acenaphthylene were generally detectable. Naphthalene was present in 7 out of 8 overhaul activities, in 2 out of 3 firehouse (kitchen and truck bay) samples, and in none collected from the control site. In firefighter face and neck wipes a greater number of PAHs were found, several of which have carcinogenic activity, such as benzofluoranthene, an agent also found in overhaul air samples. Although the concentration for naphthalene, and all other individual PAHs, was very low, the potential simultaneous exposure to multiple chemicals even in small quantities in combination with high ultrafine particle exposure deserves further study. It is recommended that personal respiratory and skin protection be worn throughout the overhaul process. PMID:24512044
NHEXAS PHASE I ARIZONA STUDY--QA ANALYTICAL RESULTS FOR METALS IN BLANK SAMPLES
The Metals in Blank Samples data set contains the analytical results of measurements of up to 27 metals in 82 blank samples from 26 households. Measurements were made in blank samples of dust, indoor and outdoor air, personal air, food, beverages, blood, urine, and dermal wipe r...
Melstrom, Paul; Koszowski, Bartosz; Thanner, Meridith Hill; Hoh, Eunha; King, Brian; Bunnell, Rebecca; McAfee, Tim
2017-09-01
Few studies have examined the extent of inhalation or dermal contact among bystanders following short-term, secondhand e-cigarette exposure. Measure PM2.5 (particles < 2.5 microns), UF (ultrafine particles < 100 nm), and nicotine in air and deposited on surfaces and clothing pre-/during/post- a short-term (2-hour) e-cigarette exposure. E-cigarettes were used ad libitum by three experienced users for 2 hours during two separate sessions (disposable e-cigarettes, then tank-style e-cigarettes, or "tanks") in a 1858 ft3 room. We recorded: uncorrected PM2.5 (using SidePak); UF (using P-Trak); air nicotine concentrations (using air samplers; SKC XAD-4 canisters); ambient air exchange rate (using an air capture hood). Wipe samples were taken by wiping 100 cm2 room surfaces pre- and post- both sessions, and clean cloth wipes were worn during the exposure and collected at the end. Uncorrected PM2.5 and UF were higher (p < .0001) during sessions than before or after. Median PM2.5 during exposure was higher using tanks (0.515 mg/m3) than disposables (0.035 mg/m3) (p < .0001). Median UF during exposure was higher using disposables (31 200 particles/cm3) than tanks (25 200 particles/cm3)(p < .0001). Median air nicotine levels were higher (p < .05) during both sessions (disposables = 0.697 ng/L, tanks = 1.833 ng/L) than before (disposables = 0.004 ng/L, tanks = 0.010 ng/L) or after (disposables = 0.115 ng/L, tanks = 0.147 ng/L). Median accumulation rates of nicotine on surface samples were 2.1 ng/100 cm2/h using disposables and 4.0 ng/100 cm2/h using tanks; for cloth samples, it was 44.4 ng/100 cm2/h using disposables and 69.6 ng/100 cm2/h using tanks (p < .01). Mean room ventilation rate was ~5 air changes per hour during both sessions. Short-term e-cigarette use can produce: elevated PM2.5; elevated UF; nicotine in the air; and accumulation of nicotine on surfaces and clothing. Short-term indoor e-cigarette use produced accumulation of nicotine on surfaces and clothing, which could lead to dermal exposure to nicotine. Short-term e-cigarette use produced elevated PM2.5 and ultrafine particles, which could lead to secondhand inhalation of these particles and any chemicals associated with them by bystanders. We measured significant differences in PM2.5 and ultrafine particles between disposable e-cigarettes and tank-style e-cigarettes, suggesting a difference in the exposure profiles of e-cigarette products. Published by Oxford University Press on behalf of Society for Research on Nicotine and Tobacco 2017. This work is written by (a) US Government employee(s) and is in the public domain in the US.
Efficacy of commercially available wipes for disinfection of pulse oximeter sensors.
Nandy, Poulomi; Lucas, Anne D; Gonzalez, Elizabeth A; Hitchins, Victoria M
2016-03-01
This study examined the effectiveness of commercially available disinfecting wipes and cosmetic wipes in disinfecting pulse oximeter sensors contaminated with pathogenic bacterial surrogates. Surrogates of potential biological warfare agents and bacterial pathogens associated with hospital-acquired infections (HAIs) were spotted on test surfaces, with and without an artificial test soil (sebum), allowed to dry, and then cleaned with different commercially available cleaning and disinfecting wipes or sterile gauze soaked in water, bleach (diluted 1:10), or 70% isopropanol. The percentage of microbial survival and an analytical estimation of remaining test soil on devices were determined. Wipes containing sodium hypochlorite as the active ingredient and gauze soaked in bleach (1:10) were the most effective in removing both vegetative bacteria and spores. In the presence of selective disinfectants, sebum had a protective effect on vegetative bacteria, but not on spores. The presence of sebum reduces the cleaning efficiency of some commercially available wipes for some select microbes. Various commercial wipes performed significantly better than the designated cleaning agent (70% isopropanol) in disinfecting the oximetry sensor. Cosmetic wipes were not more effective than the disinfecting wipes in removing sebum. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. All rights reserved.
Report to DHS on Summer Internship 2006
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beckwith, R H
2006-07-26
This summer I worked at Lawrence Livermore National Laboratory in a bioforensics collection and extraction research group under David Camp. The group is involved with researching efficiencies of various methods for collecting bioforensic evidence from crime scenes. The different methods under examination are a wipe, swab, HVAC filter and a vacuum. The vacuum is something that has particularly gone uncharacterized. My time was spent mostly on modeling and calculations work, but at the end of the summer I completed my internship with a few experiments to supplement my calculations. I had two major projects this summer. My first major projectmore » this summer involved fluid mechanics modeling of collection and extraction situations. This work examines different fluid dynamic models for the case of a micron spore attached to a fiber. The second project I was involved with was a statistical analysis of the different sampling techniques.« less
U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--QA ANALYTICAL RESULTS FOR METALS IN BLANK SAMPLES
The Metals in Blank Samples data set contains the analytical results of measurements of up to 27 metals in 52 blank samples. Measurements were made in blank samples of dust, indoor air, food, water, and dermal wipe residue. Blank samples were used to assess the potential for sa...
Six children with allergic contact dermatitis to methylisothiazolinone in wet wipes (baby wipes).
Chang, Mary Wu; Nakrani, Radhika
2014-02-01
Methylchloroisothiazolinone/methylisothiazolinone (MCI/MI) is a combination preservative used in personal care and household products and is a common cause of allergic contact dermatitis (ACD). Recently, MI alone, without MCI, has been increasingly used in consumer products in attempts to minimize allergic reactions. Wet wipes are extensively tested and traditionally believed to be innocuous. MI in wet wipes ("baby wipes") has not been previously reported to cause ACD in children in the United States. Only 1 previous report of ACD in a child in Belgium has been recently reported. We report 6 children with chronic, perianal/buttock, and facial eczematous dermatitis, refractory to multiple topical and oral antibiotics and corticosteroids. All tested positive to MCI/MI on patch testing. None wore diapers. All patients had been using wet wipes containing MI (without MCI) to affected areas. Discontinuation of wipes resulted in rapid and complete resolution. This is the first report of pediatric ACD to MI in wet wipes in the United States, and the largest series to date. ACD to MI in wet wipes is frequently misdiagnosed as eczema, impetigo, or psoriasis. Wet wipes are increasingly marketed in personal care products for all ages, and MI exposure and sensitization will likely increase. Dermatitis of the perianal, buttock, facial, and hand areas with a history of wet wipe use should raise suspicion of ACD to MI and prompt appropriate patch testing. Rapid resolution occurs after the allergen exposure is eliminated. All isothiozolinones should be avoided in personal care and household products for these patients.
Breath biomarkers in toxicology.
Pleil, Joachim D
2016-11-01
Exhaled breath has joined blood and urine as a valuable resource for sampling and analyzing biomarkers in human media for assessing exposure, uptake metabolism, and elimination of toxic chemicals. This article focuses current use of exhaled gas, aerosols, and vapor in human breath, the methods for collection, and ultimately the use of the resulting data. Some advantages of breath are the noninvasive and self-administered nature of collection, the essentially inexhaustible supply, and that breath sampling does not produce potentially infectious waste such as needles, wipes, bandages, and glassware. In contrast to blood and urine, breath samples can be collected on demand in rapid succession and so allow toxicokinetic observations of uptake and elimination in any time frame. Furthermore, new technologies now allow capturing condensed breath vapor directly, or just the aerosol fraction alone, to gain access to inorganic species, lung pH, proteins and protein fragments, cellular DNA, and whole microorganisms from the pulmonary microbiome. Future applications are discussed, especially the use of isotopically labeled probes, non-targeted (discovery) analysis, cellular level toxicity testing, and ultimately assessing "crowd breath" of groups of people and the relation to dose of airborne and other environmental chemicals at the population level.
[Determination of lead in edible salt with solid-phase extraction and GFAAS].
Zhao, Xin; Zhou, Shuang; Ma, Lan; Yang, Dajin
2013-01-01
Establishing a method for determination of lead in salt with solid-phase extraction and GFAAS. Salt sample was diluted to a certain volume directly with ammonium acetate, then the sample solution was filtered through the solid phase extraction column which has been pre-activated. Lead ions were retained, and the sodium chloride matrix was removed. After elution, the collected lead ions was determined by graphite furnace atomic absorption spectrometry in 257.4 nm. This method can be used effectively to wipe off the sodium chloride in matrix. The limit of detection was 0.7 microg/kg and the limit of quantification was 2 microg/kg. Solid phase extraction technique can be used effectively to reduce the interference in matrix and improves the accuracy and reproducibility of detection.
Ogai, K; Matsumoto, M; Aoki, M; Ota, R; Hashimoto, K; Wada, R; Kobayashi, M; Sugama, J
2017-11-01
Presently, skin-cleaning agents that claim to be removed by water or wiping alone are commercially available and have been used for the purpose of bed baths. However, there is a lack of knowledge on how water washing and wiping differently affect skin physiological functions or ceramide content. The aim of this study was to compare the effects of water washing and wiping on skin physiological functions and ceramide content. Three kinds of the cleaning agents with different removal techniques (ie, water washing and wiping) were used in this study. Skin physiological functions (ie, transepidermal water loss, skin hydration, and skin pH) and skin ceramide content were measured before and after seven consecutive days of the application of each cleaning agent. No significant differences in skin physiological functions or ceramide content were observed between water washing and wiping. Cleaning agents that claim to be removed by water washing or wiping do not affect skin physiological functions or ceramide content by either removal method. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Celeiro, Maria; Lamas, J Pablo; Garcia-Jares, Carmen; Llompart, Maria
2015-03-06
Baby wipes and wet toilet paper are specific hygiene care daily products used on newborn and children skin. These products may contain complexes mixtures of harmful chemicals. A method based on pressurized liquid extraction (PLE) followed by gas chromatography-mass spectrometry (GC-MS) has been developed for the simultaneous determination of sixty-five chemical compounds (fragrance allergens, preservatives, musks, and phthalates) in wipes and wet toilet paper for children. These compounds are legislated in Europe according Regulation EC No 1223/2009, being twelve of them banned for their use in cosmetics, and one of them, 3-iodo-2-propynyl butylcarbamate (IPBC), is banned in products intended for children under 3 years. Also, propyl-, and butylparaben will be prohibited in leave-on cosmetic products designed for application on the nappy area of children under 3 years from April 2015. PLE is a fast, simple, easily automated technique, which permits to integrate a clean-up step during the extraction process reducing analysis time and stages. The proposed PLE-based procedure was optimized on real non-spiked baby wipe samples by means of experimental design to study the influence on extraction of parameters such as extraction solvent, temperature, extraction time, and sorbent type. Under the selected conditions, the method was validated showing satisfactory linearity, and intra-day, and inter-day precision. Recoveries were between 80-115% for most of the compounds with relative standard deviations (RSD) lower than 15%. Finally, twenty real samples were analyzed. Thirty-six of the target analytes were detected, highlighting the presence of phenoxyethanol in all analyzed samples at high concentration levels (up to 0.8%, 800μgg(-1)). Methyl paraben (MeP), and ethyl paraben (EtP) were found in 40-50% of the samples, and the recently banned isobutyl paraben (iBuP) and isopropyl paraben (iPrP), were detected in one and seven samples, respectively, at concentrations between 0.093 and 247μgg(-1). In the case of phthalates, the forbidden phthalates dibutyl phtalate (DBP) and di(2-ethylhexyl)phthalate (DEHP) were also found in thirteen samples at low levels. All the samples contained fragrance allergens in many cases at high levels (up to 2400μgg(-1)) and three musks were detected in the samples. Excluding the banned compounds, all samples complied with the concentration limits established by the European Regulation although 25% of them did not fulfill the labeling requirements for fragrance allergens. Copyright © 2015 Elsevier B.V. All rights reserved.
Bacterial vaginosis - aftercare
... takes a sample of discharge with a sterile cotton swab. The discharge is examined under a microscope ... tampons or pads. Wear loose-fitting clothing and cotton underwear. Avoid wearing pantyhose. Wipe from front to ...
Beryllium surface levels in a military ammunition plant.
Sanderson, Wayne T; Leonard, Stephanie; Ott, Darrin; Fuortes, Laurence; Field, William
2008-07-01
This study evaluated the presence of beryllium surface contamination in a U.S. conventional munitions plant as an indicator of possible past beryllium airborne and skin exposure and used these measurements to classify job categories by potential level of exposure. Surface samples were collected from production and nonproduction areas of the plant and at regional industrial reference sites with no known history of beryllium use. Surface samples of premoistened wiping material were analyzed for beryllium mass content using inductively coupled plasma-atomic emission spectroscopy (ICP-AES) and results expressed as micrograms of beryllium per 100 square centimeters (micro g/100 cm(2)). Beryllium was detected in 87% of samples collected at the munitions plant and in 72% of the samples collected at regional reference sites. Two munitions plant samples from areas near sanders and grinders were above 3.0 micro g/100 cm(2) (U.S. Department of Energy surface contamination limit). The highest surface level found at the reference sites was 0.44 micro g/100 cm(2). Workers in areas where beryllium-containing alloy tools were sanded or ground, but not other work areas, may have been exposed to airborne beryllium concentrations above levels encountered in other industries where metal work is conducted. Surface sampling provided information useful for categorizing munitions plant jobs by level of past beryllium airborne and skin exposure and, subsequently, for identifying employees within exposure strata to be screened for beryllium sensitization.
Shepard, Michele; Brenner, Sara
2014-01-01
Numerous studies are ongoing in the fields of nanotoxicology and exposure science; however, gaps remain in identifying and evaluating potential exposures from skin contact with engineered nanoparticles in occupational settings. The aim of this study was to identify potential cutaneous exposure scenarios at a workplace using engineered nanoparticles (alumina, ceria, amorphous silica) and evaluate the presence of these materials on workplace surfaces. Process review, workplace observations, and preliminary surface sampling were conducted using microvacuum and wipe sample collection methods and transmission electron microscopy with elemental analysis. Exposure scenarios were identified with potential for incidental contact. Nanoparticles of silica or silica and/or alumina agglomerates (or aggregates) were identified in surface samples from work areas where engineered nanoparticles were used or handled. Additional data are needed to evaluate occupational exposures from skin contact with engineered nanoparticles; precautionary measures should be used to minimize potential cutaneous exposures in the workplace.
40 CFR 761.372 - Specific requirements for relatively clean surfaces.
Code of Federal Regulations, 2012 CFR
2012-07-01
... that each 900 cm2 (1 square foot) of the surface is always very wet for 1 minute. Wipe smooth surfaces with a solvent-soaked, disposable absorbent pad such that each 900 cm2 (1 square foot) is wiped for 1 minute. Any surface square foot shall also be wiped for 1 minute. Wipe, mop, and/or sorb the solvent...
40 CFR 761.372 - Specific requirements for relatively clean surfaces.
Code of Federal Regulations, 2014 CFR
2014-07-01
... that each 900 cm2 (1 square foot) of the surface is always very wet for 1 minute. Wipe smooth surfaces with a solvent-soaked, disposable absorbent pad such that each 900 cm2 (1 square foot) is wiped for 1 minute. Any surface square foot shall also be wiped for 1 minute. Wipe, mop, and/or sorb the solvent...
Allergenic Ingredients in Personal Hygiene Wet Wipes.
Aschenbeck, Kelly A; Warshaw, Erin M
Wet wipes are a significant allergen source for anogenital allergic contact dermatitis. The aim of the study was to calculate the frequency of potentially allergenic ingredients in personal hygiene wet wipes. Ingredient lists from brand name and generic personal hygiene wet wipes from 4 large retailers were compiled. In the 54 personal hygiene wet wipes evaluated, a total of 132 ingredients were identified (average of 11.9 ingredients per wipe). The most common ingredients were Aloe barbadensis (77.8%), citric acid (77.8%), fragrance (72.2%), sorbic acid derivatives (63.0%), tocopherol derivatives (63.0%), glycerin (59.3%), phenoxyethanol (55.6%), disodium cocoamphodiacetate (53.7%), disodium ethylenediaminetetraacetic acid (EDTA) (42.6%), propylene glycol (42.6%), iodopropynyl butylcarbamate (40.7%), chamomile extracts (38.9%), sodium benzoate (35.2%), bronopol (22.2%), sodium citrate (22.2%), lanolin derivatives (20.4%), parabens (20.4%), polyethylene glycol derivatives (18.5%), disodium phosphate (16.7%), dimethylol dimethyl hydantoin (DMDM) (14.8%), and cocamidopropyl propylene glycol (PG)-dimonium chloride phosphate (11.1%). Of note, methylisothiazolinone (5.6%) was uncommon; methylchloroisothiazolinone was not identified in the personal hygiene wet wipes examined. There are many potential allergens in personal hygiene wet wipes, especially fragrance and preservatives.
RAPID SPATIAL MAPPING OF CHEMICALS DISPERSED ACROSS SURFACES USING AN AUTOSAMPLER/DART/TOFMS
Rapid identification and semi-quantitation of chemicals spatially dispersed and
deposited on surfaces by accidental, deliberate, or weather-related events requires analysis of
hundreds of samples, usually obtained by sampling with wipes. Hand-held devices used on-si...
Protocol for Detection of Bacillus anthracis in Environmental Samples
This pProtocol Method describes proceduresintended for the analyses of swabs, wipes, Sponge-Sticks, vacuum socks and filters, air filters, drinking water, and decontamination waste water for Bacillus anthracis spores.
Does Nosema ceranae Wipe Out Nosema apis in Turkey?
Ivgin Tunca, Rahşan; Oskay, Devrim; Gosterit, Ayhan; Tekin, Olgay Kaan
2016-01-01
The aim of this study was to determine the prevalence of the Nosema ceranae and Nosema apis among apiaries using both spore counts and multiplex PCR and the replacement of N. apis by N. ceranae in some regions of Turkey. A hundred honey bee samples were collected from 99 apiaries in 11 different locations in 2011-2012 in Turkey. Nosema infection degree from collected samples was determined using light microscope and molecular detection of Nosema spp. ( N. ceranae and N. apis ) was performed using specific primers by multiplex PCR. N. ceranae was only found spores in sampling areas using molecular diagnosis. N. apis was not detected in whole sampling areas using both techniques. There are no Nosema spores detected in Konya one location using two techniques. The nucleotide sequences from amplification products of the Nosema infested honeybee samples were (98%) identical with the sequence of N. ceranae for many countries deposited in the GenBank database in this study. The present study illustrated that N. ceranae is the only spores for sampled areas in 2011-2012. The study could also indicate that N. ceranae has been replaced instead of N . apis in Turkey. In addition, the prevalence of N. ceranae and two microsporodia spores effects on honey bee colonies in Turkey were needed to determine with intensive sampling, periodically.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gulson, Brian, E-mail: brian.gulson@mq.edu.au; CSIRO Earth Science and Resource Engineering, North Ryde NSW 2113; Anderson, Phil
Background: As part of the only national survey of lead in Australian children, which was undertaken in 1996, lead isotopic and lead concentration measurements were obtained from children from 24 dwellings whose blood lead levels were ≥15 µg/dL in an attempt to determine the source(s) of their elevated blood lead. Comparisons were made with data for six children with lower blood lead levels (<10 µg/dL). Methods: Thermal ionisation and isotope dilution mass spectrometry were used to determine high precision lead isotopic ratios ({sup 208}Pb/{sup 206}Pb, {sup 207}Pb/{sup 206}Pb and {sup 206}Pb/{sup 204}Pb) and lead concentrations in blood, dust from floormore » wipes, soil, drinking water and paint (where available). Evaluation of associations between blood and the environmental samples was based on the analysis of individual cases, and Pearson correlations and multiple regression analyses based on the whole dataset. Results and discussion: The correlations showed an association for isotopic ratios in blood and wipes (r=0.52, 95% CI 0.19–0.74), blood and soil (r=0.33, 95% CI −0.05–0.62), and blood and paint (r=0.56, 95% CI 0.09–0.83). The regression analyses indicated that the only statistically significant relationship for blood isotopic ratios was with dust wipes (B=0.65, 95% CI 0.35–0.95); there were no significant associations for lead concentrations in blood and environmental samples. There is a strong isotopic correlation of soils and house dust (r=0.53, 95% CI 0.20–0.75) indicative of a common source(s) for lead in soil and house dust. In contrast, as with the regression analyses, no such association is present for bulk lead concentrations (r=−0.003, 95% CI −0.37–0.36), the most common approach employed in source investigations. In evaluation of the isotopic results on a case by case basis, the strongest associations were for dust wipes and blood. -- Highlights: • Children with elevated blood lead ≥15 µg/dL compared with a group with <10 µg/dL. • High precision lead isotopic ratios in blood, house dust wipes, soil, water, paint. • Associations for isotopic measures of blood and dust, blood and soil, blood and paint. • Regressions gave significance for isotopic measures of blood/dust and dust/soil.« less
... prefold diapers) a container of warm water and cotton balls (for babies with sensitive skin) or a ... ability to roll. Wiping Using the wet washcloth, cotton balls, or baby wipes, gently wipe your baby ...
Seenama, Chakkraphong; Tachasirinugune, Peenithi; Jintanothaitavorn, Duangporn; Kachintorn, Kanchana; Thamlikitkul, Visanu
2013-02-01
To determine the effectiveness of Virusolve+ disinfectant wipes and PAL disinfectant wipes for decontamination of inoculated bacteria on patients' environmental and medical equipment surfaces at Siriraj Hospital. Tryptic soy broths containing MRSA and XDR A. baumannii were painted onto the surfaces of patient's stainless steel bed rail, patient's fiber footboard, control panel of infusion pump machine and control panel of respirator. The contaminated surfaces were cleaned by either tap water, tap water containing detergent, Virusolve+ disinfectant wipes or PAL disinfectant wipes. The surfaces without any cleaning procedures served as the control surface. The contaminated surfaces cleaned with the aforementioned procedures and control surfaces were swabbed with cotton swabs. The swabs were streaked on agar plates to determine the presence of MRSA and XDR A. baumannii. MRSA and XDR A. baumannii were recovered from all control surfaces. All surfaces cleaned with tap water or tap water containing detergent revealed presence of both MRSA and XDR A. baumannii. However the amounts of bacteria on the surfaces cleaned with tap water containing detergent were less than those cleaned with tap water alone. All surfaces cleaned with PAL disinfectant wipes also revealed presence of both MRSA and XDR A. baumannii. However the amounts of bacteria on the surfaces cleaned with PAL disinfectant wipes were less than those cleaned with tap water containing detergent. No bacteria were recovered from all surfaces cleaned with Virusolve+ disinfectant wipes. Virusolve+ disinfectant wipes were more effective than tap water; tap water containing detergent and PAL disinfectant wipes for decontamination of bacteria inoculated on patients environmental and medical equipment surfaces at Siriraj Hospital.
Bliss, Nola; Stull, Jason W; Moeller, Steven J; Rajala-Schultz, Päivi J; Bowman, Andrew S
2017-09-15
OBJECTIVE To identify the geographic distribution of exhibition swine in the Midwestern United States, characterize management practices used for exhibition swine, and identify associations between those practices and influenza A virus (IAV) detection in exhibition swine arriving at county or state agricultural fairs. DESIGN Cross-sectional survey. SAMPLE 480 swine exhibitors and 641 exhibition swine. PROCEDURES Inventories of swine exhibited at fairs in 6 selected Midwestern states during 2013 and of the total swine population (including commercial swine) in these regions in 2012 were obtained and mapped. In 2014, snout wipe samples were collected from swine on arrival at 9 selected fairs in Indiana (n = 5) and Ohio (4) and tested for the presence of IAV. Also at fair arrival, swine exhibitors completed a survey regarding swine management practices. RESULTS Contrary to the total swine population, the exhibition swine population was heavily concentrated in Indiana and Ohio. Many swine exhibitors reported attending multiple exhibitions within a season (median number, 2; range, 0 to 50), with exhibited swine often returned to their farm of origin. Rearing of commercial and exhibition swine on the same premises was reported by 13.3% (56/422) of exhibitors. Hosting an on-farm open house or sale was associated with an increased odds of IAV detection in snout wipe samples. CONCLUSIONS AND CLINICAL RELEVANCE The exhibition swine population was highly variable and differed from the commercial swine population in terms of pig density across geographic locations, population integrity, and on-farm management practices. Exhibition swine may be important in IAV transmission, and identified biosecurity deficiencies may have important public and animal health consequences.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Piepel, Gregory F.; Amidan, Brett G.; Hu, Rebecca
2011-11-28
This report summarizes previous laboratory studies to characterize the performance of methods for collecting, storing/transporting, processing, and analyzing samples from surfaces contaminated by Bacillus anthracis or related surrogates. The focus is on plate culture and count estimates of surface contamination for swab, wipe, and vacuum samples of porous and nonporous surfaces. Summaries of the previous studies and their results were assessed to identify gaps in information needed as inputs to calculate key parameters critical to risk management in biothreat incidents. One key parameter is the number of samples needed to make characterization or clearance decisions with specified statistical confidence. Othermore » key parameters include the ability to calculate, following contamination incidents, the (1) estimates of Bacillus anthracis contamination, as well as the bias and uncertainties in the estimates, and (2) confidence in characterization and clearance decisions for contaminated or decontaminated buildings. Gaps in knowledge and understanding identified during the summary of the studies are discussed and recommendations are given for future studies.« less
Preparation of paper scintillator for detecting 3H contaminant.
Miyoshi, Hirokazu; Ikeda, Toshiji
2013-09-01
Liquid scintillator (LS)-encapsulated silica was prepared by the sol-gel method and then was added dropwise onto a wipe paper to form a paper scintillator. First, the efficiencies of wipe were determined for both the paper scintillator and the wipe paper using a liquid scintillation counter (LSC). The efficiencies of wipe using the paper scintillator and the wipe paper were 88 and 36 %, respectively. The detection efficiencies were 5.5 % for the paper scintillator, 46 % for the wipe paper using an LS and 0.08 % for the (3)H/(14)C survey meter, respectively, compared with that of a melt-on scintillator of 47 %. Second, an (3)H contaminant on the paper scintillator was successfully detected using a photomultiplier without an LSC or an (3)H/(14)C survey meter. Finally, the paper scintillator was able to detect beta rays of the (3)H contaminant easily without an LS.
Review Process for the Registration and Use Directions for Floor Wipe Towelette Products
This guidance provides Antimicrobials Division staff with guidance related to the registration requirements and use directions for presaturated/impregnated floor wipe towelette products. This document will be used for new and existing wipe registrations.
Stowell, Jennifer D; Forlin-Passoni, Daniela; Radford, Kay; Bate, Sheri L; Dollard, Sheila C; Bialek, Stephanie R; Cannon, Michael J; Schmid, D Scott
2014-01-01
Congenital cytomegalovirus (CMV) transmission can occur when women acquire CMV while pregnant. Infection control guidelines may reduce risk for transmission. We studied the duration of CMV survival after application of bacteria to the hands and after transfer from the hands to surfaces and the effectiveness of cleansing with water, regular and antibacterial soaps, sanitizer, and diaper wipes. Experiments used CMV AD169 in saliva at initial titers of 1 × 10(5) infectious particles/ml. Samples from hands or surfaces (points between 0 and 15 min) were placed in culture and observed for at least 2 weeks. Samples were also tested using CMV real-time PCR. After application of bacteria to the hands, viable CMV was recovered from 17/20 swabs at 0 min, 18/20 swabs at 1 min, 5/20 swabs at 5 min, and 4/20 swabs at 15 min. After transfer, duration of survival was at least 15 min on plastic (1/2 swabs), 5 min on crackers and glass (3/4 swabs), and 1 min or less on metal and cloth (3/4 swabs); no viable virus was collected from wood, rubber, or hands. After cleansing, no viable virus was recovered using water (0/22), plain soap (0/20), antibacterial soap (0/20), or sanitizer (0/22). Viable CMV was recovered from 4/20 hands 10 min after diaper wipe cleansing. CMV remains viable on hands for sufficient times to allow transmission. CMV may be transferred to surfaces with reduced viability. Hand-cleansing methods were effective at eliminating viable CMV from hands.
Stowell, Jennifer D.; Forlin-Passoni, Daniela; Radford, Kay; Bate, Sheri L.; Dollard, Sheila C.; Bialek, Stephanie R.; Cannon, Michael J.
2014-01-01
Congenital cytomegalovirus (CMV) transmission can occur when women acquire CMV while pregnant. Infection control guidelines may reduce risk for transmission. We studied the duration of CMV survival after application of bacteria to the hands and after transfer from the hands to surfaces and the effectiveness of cleansing with water, regular and antibacterial soaps, sanitizer, and diaper wipes. Experiments used CMV AD169 in saliva at initial titers of 1 × 105 infectious particles/ml. Samples from hands or surfaces (points between 0 and 15 min) were placed in culture and observed for at least 2 weeks. Samples were also tested using CMV real-time PCR. After application of bacteria to the hands, viable CMV was recovered from 17/20 swabs at 0 min, 18/20 swabs at 1 min, 5/20 swabs at 5 min, and 4/20 swabs at 15 min. After transfer, duration of survival was at least 15 min on plastic (1/2 swabs), 5 min on crackers and glass (3/4 swabs), and 1 min or less on metal and cloth (3/4 swabs); no viable virus was collected from wood, rubber, or hands. After cleansing, no viable virus was recovered using water (0/22), plain soap (0/20), antibacterial soap (0/20), or sanitizer (0/22). Viable CMV was recovered from 4/20 hands 10 min after diaper wipe cleansing. CMV remains viable on hands for sufficient times to allow transmission. CMV may be transferred to surfaces with reduced viability. Hand-cleansing methods were effective at eliminating viable CMV from hands. PMID:24185855
Colombo, Manuel; Jeronimo, Matthew; Astrakianakis, George; Apte, Chirag; Hon, Chun-Yip
2017-10-01
This paper describes a novel wipe sampling and high-performance liquid chromatography/tandem mass spectrometry (HPLC-MS/MS) method capable of simultaneously detecting 10 antineoplastic drugs (5-fluorouracil, oxaliplatin, methotrexate, vindesine, ifosfamide, cyclophosphamide, vincristine, vinblastine, docetaxel, and paclitaxel). The good overall recoveries and sensitivity values of this method along with the comparatively short run time (8 min) allows for its use in routine monitoring in health care facilities. The long-term behavior of the studied drugs on contaminated surfaces and the effect of surface roughness on drug recoveries were studied to gain insights about how these environmental variables influence the detection, cleaning, and occupational exposure of these drugs. Surfaces with higher roughness parameter (Ra) values (rougher) had the lowest recoveries while those with lower Ra (smoother) presented the highest recoveries. Long-term assessments evidence distinctive drug behaviors with oxaliplatin, vindesine, vincristine, and vinblastine being the less persistent drugs (~20% was recovered after 24 h) and docetaxel and paclitaxel the most persistent drugs with recoveries of 40% and 80% after 1 month. This information indicates the importance of collecting ancillary information about drug usage (throughput, timing, cleaning procedures, etc.) to interpret the results in the context of potential exposure. Finally, the method was successfully applied to evaluate trace surface contamination down to the single picogram per square centimeter in multiple work areas within three local health care centers on Vancouver Island, Canada. © The Author 2017. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.
Residual tobacco smoke pollution in used cars for sale: air, dust, and surfaces.
Matt, Georg E; Quintana, Penelope J E; Hovell, Melbourne F; Chatfield, Dale; Ma, Debbie S; Romero, Romina; Uribe, Anna
2008-09-01
Regular tobacco use in the enclosed environment of a car raises concerns about longer-term contamination of a car's microenvironment with residual secondhand smoke pollutants. This study (a) developed and compared methods to measure residual contamination of cars with secondhand smoke, (b) examined whether cars of smokers and nonsmokers were contaminated by secondhand smoke, and (c) how smoking behavior and restrictions affected contamination levels. Surface wipe, dust, and air samples were collected in used cars sold by nonsmokers (n = 20) and smokers (n = 87) and analyzed for nicotine. Sellers were interviewed about smoking behavior and restrictions, and car interiors were inspected for signs of tobacco use. Cars of smokers who smoked in their vehicles showed significantly elevated levels of nicotine (p < .001) in dust, on surfaces, and in the air compared with nonsmoker cars with smoking ban. When smokers imposed car smoking bans, air nicotine levels were significantly lower (p < .01), but dust and surface contamination levels remained at similar levels. Smoking more cigarettes in the car and overall higher smoking rate of the seller were significantly associated with higher secondhand smoke contamination of the car (p < .001). Use of a cutpoint for nicotine levels from surface wipe samples correctly identified 82% of smoker cars without smoking bans, 75% of smoker cars with bans, and 100% of nonsmoker cars. Surface nicotine levels provide a relatively inexpensive and accurate method to identify cars and other indoor environments contaminated with residual secondhand smoke. Disclosure requirements and smoke-free certifications could help protect nonsmoking buyers of used cars.
USDA-ARS?s Scientific Manuscript database
Broilers may carry Salmonella and Campylobacter on inner and outer surfaces upon arrival at the slaughter plant and carcasses can be further contaminated during commercial processing. A sensitive, non-destructive, repeatable sampling method would be useful to test carcasses for levels of bacteria b...
Lavender, Tina; Furber, Christine; Campbell, Malcolm; Victor, Suresh; Roberts, Ian; Bedwell, Carol; Cork, Michael J
2012-06-01
Some national guidelines recommend the use of water alone for napkin cleansing. Yet, there is a readiness, amongst many parents, to use baby wipes. Evidence from randomised controlled trials, of the effect of baby wipes on newborn skin integrity is lacking. We conducted a study to examine the hypothesis that the use of a specifically formulated cleansing wipe on the napkin area of newborn infants (<1 month) has an equivalent effect on skin hydration when compared with using cotton wool and water (usual care). A prospective, assessor-blinded, randomised controlled equivalence trial was conducted during 2010. Healthy, term babies (n=280), recruited within 48 hours of birth, were randomly assigned to have their napkin area cleansed with an alcohol-free baby wipe (140 babies) or cotton wool and water (140 babies). Primary outcome was change in hydration from within 48 hours of birth to 4 weeks post-birth. Secondary outcomes comprised changes in trans-epidermal water loss, skin surface pH and erythema, presence of microbial skin contaminants/irritants at 4 weeks and napkin dermatitis reported by midwife at 4 weeks and mother during the 4 weeks. Complete hydration data were obtained for 254 (90.7 %) babies. Wipes were shown to be equivalent to water and cotton wool in terms of skin hydration (intention-to-treat analysis: wipes 65.4 (SD 12.4) vs. water 63.5 (14.2), p=0.47, 95% CI -2.5 to 4.2; per protocol analysis: wipes 64.6 (12.4) vs. water 63.6 (14.3), p=0.53, 95% CI -2.4 to 4.2). No significant differences were found in the secondary outcomes, except for maternal-reported napkin dermatitis, which was higher in the water group (p=0.025 for complete responses). Baby wipes had an equivalent effect on skin hydration when compared with cotton wool and water. We found no evidence of any adverse effects of using these wipes. These findings offer reassurance to parents who choose to use baby wipes and to health professionals who support their use. Current Controlled Trials ISRCTN86207019.
USDA-ARS?s Scientific Manuscript database
Advances in nanotechnology are creating synergy with nonwoven technology in cleaning and/or disinfecting power for the next generation of wipe products. However, there is little known about the use of cotton fiber in wipes as a nanoengineering tool, which self-produces silver nanoparticles -- one of...
Allergenic Ingredients in Facial Wet Wipes.
Aschenbeck, Kelly A; Warshaw, Erin M
Allergic contact dermatitis commonly occurs on the face. Facial cleansing wipes may be an underrecognized source of allergens. The aim of this study was to determine the frequency of potentially allergenic ingredients in facial wet wipes. Ingredient lists from name brand and generic facial wipes from 4 large retailers were analyzed. In the 178 facial wipes examined, a total of 485 ingredients were identified (average, 16.7 ingredients per wipe). Excluding botanicals, the top 15 potentially allergenic ingredients were glycerin (64.0%), fragrance (63.5%), phenoxyethanol (53.9%), citric acid (51.1%), disodium EDTA (44.4%), sorbic acid derivatives (39.3%), tocopherol derivatives (38.8%), polyethylene glycol derivatives (32.6%), glyceryl stearate (31.5%), sodium citrate (29.8%), glucosides (27.5%), cetearyl alcohol (25.8%), propylene glycol (25.3%), sodium benzoate (24.2%), and ceteareth-20 (23.6%)/parabens (23.6%). Of note, methylisothiazolinone (2.2%) and methylchloroisothiazolinone (1.1%) were uncommon. The top potential allergens of botanical origin included Aloe barbadensis (41.0%), chamomile extracts (27.0%), tea extracts (21.3%), Cucumis sativus (20.2%), and Hamamelis virginiana (10.7%). Many potential allergens are present in facial wet wipes, including fragrances, preservatives, botanicals, glucosides, and propylene glycol.
Quat co-formulations optimized for use with cotton nonwoven disposable wipes
USDA-ARS?s Scientific Manuscript database
Quaternary ammonium compounds, commonly referred to as quats, are cationic surfactants widely used as the active biocidal ingredient for disposable disinfecting wipes. The cationic nature of quats results in a strong ionic interaction and adsorption onto wipes materials that have an anionic surface...
Cox, Jennie; Indugula, Reshmi; Vesper, Stephen; Zhu, Zheng; Jandarov, Roman; Reponen, Tiina
2017-10-18
Evaluating fungal contamination indoors is complicated because of the many different sampling methods utilized. In this study, fungal contamination was evaluated using five sampling methods and four matrices for results. The five sampling methods were a 48 hour indoor air sample collected with a Button™ inhalable aerosol sampler and four types of dust samples: a vacuumed floor dust sample, newly settled dust collected for four weeks onto two types of electrostatic dust cloths (EDCs) in trays, and a wipe sample of dust from above floor surfaces. The samples were obtained in the bedrooms of asthmatic children (n = 14). Quantitative polymerase chain reaction (qPCR) was used to analyze the dust and air samples for the 36 fungal species that make up the Environmental Relative Moldiness Index (ERMI). The results from the samples were compared by four matrices: total concentration of fungal cells, concentration of fungal species associated with indoor environments, concentration of fungal species associated with outdoor environments, and ERMI values (or ERMI-like values for air samples). The ERMI values for the dust samples and the ERMI-like values for the 48 hour air samples were not significantly different. The total cell concentrations of the 36 species obtained with the four dust collection methods correlated significantly (r = 0.64-0.79, p < 0.05), with the exception of the vacuumed floor dust and newly settled dust. In addition, fungal cell concentrations of indoor associated species correlated well between all four dust sampling methods (r = 0.68-0.86, p < 0.01). No correlation was found between the fungal concentrations in the air and dust samples primarily because of differences in concentrations of Cladosporium cladosporioides Type 1 and Epicoccum nigrum. A representative type of dust sample and a 48 hour air sample might both provide useful information about fungal exposures.
2010-05-01
absorption. Thermogravimetric Analysis (TGA) was employed to measure absorption of HD and GD into the nylon fabric. TGA is an analytical tool useful in...Chromatography Analysis 26 4.4.5.1 Mass Removed by Wiper at Room Temperature 26 4.4.6 Chemical Agent Mass Removed by Wiper at Elevated and Reduced...Temperature Tests 71 5.9 Vapor Analysis of Spent Wipe 78 5.10 Wiping Efficacy and Complex Geometries 82 5.11 Spray and Wipe Tests 84 5.12 Effect of
Sattar, S A; Bradley, C; Kibbee, R; Wesgate, R; Wilkinson, M A C; Sharpe, T; Maillard, J-Y
2015-12-01
The use of disinfectant pre-soaked wipes (DPW) to decontaminate high-touch environmental surfaces (HTES) by wiping is becoming increasingly widespread in the healthcare environment. However, DPW are rarely tested using conditions simulating their field use, and the label claims of environmental surface disinfectants seldom include wiping action. To evaluate the new E2967-15 standard test specific to wipes, particularly their ability to decontaminate surfaces and to transfer acquired contamination to clean surfaces. ASTM Standard E2967-15 was used by three independent laboratories to test the efficacy of five types of commercially available wipe products. All data generated were pulled together, and reproducibility and repeatability of the standard were measured. All the commercial DPW tested achieved a >4log10 (>99.99%) reduction in colony-forming units (CFU) of Staphylococcus aureus and Acinetobacter baumanii with 10s of wiping, but only one DPW containing 0.5% accelerated H2O2 prevented the transfer of bacteria to another surface. This newly introduced standard method represents a significant advance in assessing DPW for microbial decontamination of HTES, and should greatly assist research and development, and in making more relevant and reliable claims on marketed DPW. Copyright © 2015. Published by Elsevier Ltd.
NASA Astrophysics Data System (ADS)
Miller, Carla J.; Glenn, D. F.; Hartenstein, Steven D.; Hallowell, Susan F.
1998-12-01
Recent efforts at the Idaho National Engineering and Environmental Laboratory (INEEL) have included mapping explosive contamination resulting from manufacturing and carrying improvised explosive devices (IEDs). Two types of trace detection equipment were used to determine levels of contamination from designated sampling areas. A total of twenty IEDs were constructed: ten using TNT and ten using C-4. Two test scenarios were used. The first scenario tracked the activities of a manufacturer who straps the device onto an independent courier. The courier then performed a series of activities to simulate waiting in an airport. The second scenario tracked the activities of a manufacturer who also served as the courier. A sample set for each test consisted of thirty samples from various locations on each IED manufacturer, thirty from each IED courier, twenty-five from the manufacturing area, and twenty-five from the courier area. Pre-samples and post-samples were collected for analysis with each detection technique. Samples analyzed by gc/chemiluminescence were taken by swiping a teflon- coated sampling swipe across the surface of the sampling area to pick up any explosive particles. Samples analyzed by ion mobility spectrometry (IMS) were taken from the clothing of the manufacturer and courier by vacuuming the surface and collecting particulates on a fiberglass filter. Samples for IMS analysis from the manufacturing and courier rooms were taken by wiping a cotton sampling swipe across the surface area. Currently, building IEDs and monitoring the explosive contamination is being directed toward detection with portal monitors.
Shepard, Michele; Brenner, Sara
2014-01-01
Background: Numerous studies are ongoing in the fields of nanotoxicology and exposure science; however, gaps remain in identifying and evaluating potential exposures from skin contact with engineered nanoparticles in occupational settings. Objectives: The aim of this study was to identify potential cutaneous exposure scenarios at a workplace using engineered nanoparticles (alumina, ceria, amorphous silica) and evaluate the presence of these materials on workplace surfaces. Methods: Process review, workplace observations, and preliminary surface sampling were conducted using microvacuum and wipe sample collection methods and transmission electron microscopy with elemental analysis. Results: Exposure scenarios were identified with potential for incidental contact. Nanoparticles of silica or silica and/or alumina agglomerates (or aggregates) were identified in surface samples from work areas where engineered nanoparticles were used or handled. Conclusions: Additional data are needed to evaluate occupational exposures from skin contact with engineered nanoparticles; precautionary measures should be used to minimize potential cutaneous exposures in the workplace. PMID:25000112
Evaluation of a Disinfectant Wipe Intervention on Fomite-to-Finger Microbial Transfer
Lopez, Gerardo U.; Kitajima, Masaaki; Havas, Aaron; Gerba, Charles P.
2014-01-01
Inanimate surfaces, or fomites, can serve as routes of transmission of enteric and respiratory pathogens. No previous studies have evaluated the impact of surface disinfection on the level of pathogen transfer from fomites to fingers. Thus, the present study investigated the change in microbial transfer from contaminated fomites to fingers following disinfecting wipe use. Escherichia coli (108 to 109 CFU/ml), Staphylococcus aureus (109 CFU/ml), Bacillus thuringiensis spores (107 to 108 CFU/ml), and poliovirus 1 (108 PFU/ml) were seeded on ceramic tile, laminate, and granite in 10-μl drops and allowed to dry for 30 min at a relative humidity of 15 to 32%. The seeded fomites were treated with a disinfectant wipe and allowed to dry for an additional 10 min. Fomite-to-finger transfer trials were conducted to measure concentrations of transferred microorganisms on the fingers after the disinfectant wipe intervention. The mean log10 reduction of the test microorganisms on fomites by the disinfectant wipe treatment varied from 1.9 to 5.0, depending on the microorganism and the fomite. Microbial transfer from disinfectant-wipe-treated fomites was lower (up to <0.1% on average) than from nontreated surfaces (up to 36.3% on average, reported in our previous study) for all types of microorganisms and fomites. This is the first study quantifying microbial transfer from contaminated fomites to fingers after the use of disinfectant wipe intervention. The data generated in the present study can be used in quantitative microbial risk assessment models to predict the effect of disinfectant wipes in reducing microbial exposure. PMID:24610856
Wipe-rinse technique for quantitating microbial contamination on large surfaces.
Kirschner, L E; Puleo, J R
1979-01-01
The evaluation of an improved wipe-rinse technique for the bioassay of large areas was undertaken due to inherent inadequacies in the cotton swab-rinse technique to which assay of spacecraft is currently restricted. Four types of contamination control cloths were initially tested. A polyester-bonded cloth (PBC) was selected for further evaluation because of its superior efficiency and handling characteristics. Results from comparative tests with PBC and cotton swabs on simulated spacecraft surfaces indicated a significantly higher recovery efficiency for the PBC than for the cotton (90.4 versus 75.2%). Of the sampling areas sites studied, PBC was found to be most effective on surface areas not exceeding 0.74 m2 (8.0 feet 2). PMID:394682
Wipe-rinse technique for quantitating microbial contamination on large surfaces
NASA Technical Reports Server (NTRS)
Kirschner, L. E.; Puleo, J. R.
1979-01-01
The evaluation of an improved wipe-rinse technique for the bioassay of large areas was undertaken due to inherent inadequacies in the cotton swab-rinse technique to which assay of spacecraft is currently restricted. Four types of contamination control cloths were initially tested. A polyester-bonded cloth (PBC) was selected for further evaluation because of its superior efficiency and handling characteristics. Results from comparative tests with PBC and cotton swabs on simulated spacecraft surfaces indicated a significantly higher recovery efficiency for the PBC than for the cotton (90.4 versus 75.2%). Of the sampling area sites studied, PBC was found to be most effective on surface areas not exceeding 0.74 sq m (8.0 sq ft).
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-31
... Waste Landfill NODA Notice of Data Availability NPDES National Pollutant Discharge Elimination System...-contaminated wipe or from the container holding the wipes. In addition, the exclusions are not applicable to... containers. The containers must be able to contain free liquids, should free liquids occur, and the...
Wiping Metal Transfer in Friction Stir Welding
NASA Technical Reports Server (NTRS)
Nunes, Arthur C., Jr.; Whitaker, Ann F. (Technical Monitor)
2001-01-01
Much evidence suggests that as the friction stir pin-tool moves along a weld seam the displacement of metal takes place by a wiping action at the surface of a plug of metal that rotates with the tool. The wiping model is explained and some consequences for the friction stir welding process are drawn.
D'Antonio, Natalie N; Rihs, John D; Stout, Janet E; Yu, Victor L
2010-11-01
The Centers for Disease Control and Prevention's guidelines for hand hygiene state that the use of alcohol-based hand wipes is not an effective substitute for the use of an alcohol-based hand rub or handwashing with an antimicrobial soap and water. The objective of this study was to determine whether a hand wipe with higher ethanol content (65.9%) is as effective as an ethanol hand rub or antimicrobial soap in removing bacteria and spores from hands. In two separate experiments, the hands of 7 subjects were inoculated with a suspension of Serratia marcescens or Geobacillus stearothermophilus. Subjects washed with each of 3 different products: 65.9% ethanol hand wipes (Sani-Hands ALC), 62% ethanol gel rub (Purell), and antimicrobial soap containing 0.75% triclosan (Kindest Kare). A total of 56 observations were analyzed for S marcescens removal and 70 observations were analyzed for G stearothermophilus removal. The rank order of product efficacy for both bacteria and spore removal was antibacterial soap > 65.9% ethanol hand wipes >62% ethanol hand rub. Mean S marcescens log reductions (±SD) for the 65.9% ethanol alcohol wipe, 62% ethanol alcohol rub, and antimicrobial foam soap were 3.44 ± 0.847, 2.32 ± 1.065, and 4.44 ± 1.018, respectively (P < .001). Mean G stearothermophilus log reductions for the 65.9% ethanol wipe, 62% ethanol rub, and antimicrobial foam soap were 0.51 ± 0.26, -0.8 ± 0.32 increase over baseline, and 1.72 ± 0.62, respectively (P < .001). The alcohol-based hand wipe containing 65.9% ethanol was significantly more effective than the 62% ethanol rub in reducing the number of viable bacteria and spores on the hands. Copyright © 2010 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.
Bregnbak, David; Thyssen, Jacob P; Jellesen, Morten S; Zachariae, Claus; Johansen, Jeanne D
2016-08-01
Chromium is an important skin sensitizer. Exposure to it has been regulated in cement, and recently in leather. Studies on the deposition of chromium ions on the skin as a result of handling different chromium-containing materials are sparse, but could improve the risk assessment of contact sensitization and allergic contact dermatitis caused by chromium. To determine whether the handling of chromium-containing samples of leather and metal results in the deposition of chromium onto the skin. Five healthy volunteers participated. For 30 min, they handled samples of leather and metal known to contain and release chromium. Skin deposition of chromium was assessed with the acid wipe sampling technique. Acid wipe sampling of the participants' fingers showed chromium deposition on the skin in all participants who had been exposed to leather (range 0.01-0.20 µg/cm(2) ) and in 3 of 5 participants after they had manually handled metal discs (range 0.02-0.04 µg/cm(2) ). We found that samples of leather and metal had the ability to deposit chromium on the skin at significant levels, in spite of a short duration of exposure. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Study on the wiping gas jet in continuous galvanizing line
NASA Astrophysics Data System (ADS)
Kweon, Yong-Hun; Kim, Heuy-Dong
2011-09-01
In the continuous hot-dip galvanizing process, the gas-jet wiping is used to control the coating thickness of moving steel strip. The high speed gas-jet discharged from the nozzle slot impinges on the strip, and at this moment, wipes the liquid coating layer dragged by a moving strip. The coating thickness is generally influenced on the flow characteristics of wiping gas-jet such as the impinging pressure distribution, pressure gradient and shear stress distribution on the surface of strip. The flow characteristics of wiping gas-jet mentioned above depends upon considerably both the process operating conditions such as the nozzle pressure, nozzle-to-strip distance and line speed, and the geometry of gas-jet wiping apparatus such as the height of nozzle slot. In the present study, the effect of the geometry of nozzle on the coating thickness is investigated with the help of a computational fluid dynamics method. The height of nozzle slot is varied in the range of 0.6mm to 1.7mm. A finite volume method (FVM) is employed to solve two-dimensional, steady, compressible Navier-Stokes equations. Based upon the results obtained, the effect of the height of nozzle slot in the gas-jet wiping process is discussed in detail. The computational results show that for a given standoff distance between the nozzle to the strip, the effective height of nozzle slot exists in achieving thinner coating thickness.
The effectiveness of a novel infant tooth wipe in high caries-risk babies 8 to15 months old.
Galganny-Almeida, Anna; Queiroz, Mellissa C; Leite, Alvaro Jorge M
2007-01-01
The purpose of this study was to assess baby and parental satisfaction and plaque-removal efficacy of a novel infant tooth wipe (Spiffies) in high caries-risk babies. Thirty-five healthy and caries-free infants were selected. Babies had never had their teeth cleaned and no primary molars were yet present. Subjects were identified with the risk factor of nightly feeding behaviors. Pre- and postcleaning oral hygiene plaque measurements were recorded and then analyzed by a blinded examiner. A manual toothbrush (Ultra Kids) was used as the control method. Infants' caregivers used their randomly assigned cleaning method without instruction. Babies returned to the clinic after a 48- to 72-hour washout period, and the procedures were repeated before and after use of the alternate method. Parental satisfaction and baby-perceived acceptance were evaluated by a questionnaire and were analyzed at the time of the visit and at bedtime. Both the infant tooth wipe and conventional brushing significantly reduced plaque levels (P < .001). Parents were more satisfied with the wipes when compared to toothbrushing, particularly after nightly feeding habits (P < .001). Similarly, infant's acceptance was higher with the wipes at daytime and significantly higher at night-time (P = .002). The Novel novel Infant infant Tooth tooth Wipe wipe provides an effective method of plaque removal before the eruption of primary molars.
Measuring aerosols generated inside armoured vehicles perforated by depleted uranium ammunition.
Parkhurst, M A
2003-01-01
In response to questions raised after the Gulf War about the health significance of exposure to depleted uranium (DU), the US Department of Defense initiated a study designed to provide an improved scientific basis for assessment of possible health effects on soldiers in vehicles struck by these munitions. As part of this study, a series of DU penetrators were fired at an Abrams tank and a Bradley fighting vehicle, and the aerosols generated by vehicle perforation were collected and characterised. A robust sampling system was designed to collect aerosols in this difficult environment and monitor continuously the sampler flow rates. The aerosol samplers selected for these tests included filter cassettes, cascade impactors, a five-stage cyclone and a moving filter. Sampler redundancy was an integral part of the sampling system to offset losses from fragment damage. Wipe surveys and deposition trays collected removable deposited particulate matter. Interior aerosols were analysed for uranium concentration and particle size distribution as a function of time. They were also analysed for uranium oxide phases, particle morphology and dissolution in vitro. These data, currently under independent peer review, will provide input for future prospective and retrospective dose and health risk assessments of inhaled or ingested DU aerosols. This paper briefly discusses the target vehicles, firing trajectories, aerosol samplers and instrumentation control systems, and the types of analyses conducted on the samples.
Macroscopic analysis of gas-jet wiping: Numerical simulation and experimental approach
NASA Astrophysics Data System (ADS)
Lacanette, Delphine; Gosset, Anne; Vincent, Stéphane; Buchlin, Jean-Marie; Arquis, Éric
2006-04-01
Coating techniques are frequently used in industrial processes such as paper manufacturing, wire sleeving, and in the iron and steel industry. Depending on the application considered, the thickness of the resulting substrate is controlled by mechanical (scraper), electromagnetic (if the entrained fluid is appropriated), or hydrodynamic (gas-jet wiping) operations. This paper deals with the latter process, referred to as gas-jet wiping, in which a turbulent slot jet is used to wipe the coating film dragged by a moving substrate. This mechanism relies on the gas-jet-liquid film interaction taking place on the moving surface. The aim of this study is to compare the results obtained by a lubrication one-dimensional model, numerical volume of fluid-large eddy simulation (VOF-LES) modeling and an experimental approach. The investigation emphasizes the effect of the controlling wiping parameters, i.e., the pressure gradient and shear stress distributions induced by the jet, on the shape of the liquid film. Those profiles obtained experimentally and numerically for a jet impinging on a dry fixed surface are compared. The effect of the substrate motion and the presence of the dragged liquid film on these actuators are analyzed through numerical simulations. Good agreement is found between the film thickness profile in the wiping zone obtained from the VOF-LES simulations and with the analytical model, provided that a good model for the wiping actuators is used. The effect of the gas-jet nozzle to substrate standoff distance on the final coating thickness is analyzed; the experimental and predicted values are compared for a wide set of conditions. Finally, the occurrence of the splashing phenomenon, which is characterized by the ejection of droplets from the runback film flow at jet impingement, thus limiting the wiping process, is investigated through experiments and numerical simulations.
Working principle of an electromagnetic wiping system
NASA Astrophysics Data System (ADS)
Ernst, R.; Fautrelle, Y.; Bianchi, A.-M.; Iliescu, M.
2009-03-01
In galvanizing lines, the gas knife wiping device works well for controlling the zinc coating thickness up to 2 to 3 m/s strip velocities. But for higher velocities, a strong liquid zinc splash risk forbids the gas pressure increase, which would be necessary to keep the same thickness control efficiency of the knives. That is why a complementary electromagnetic wiping system, whose purpose is to pre-wipe the liquid zinc before the gas knives take over, is presented here. After mentioning different kinds of AC and DC possible electromagnetic solutions, a DC field electromagnetic brake (EMB) system based on the use of permanent magnets is selected for a future experimental implementation. In order to better understand the electromagnetic and fluid mechanics phenomena, an analytical model and then different numerical models are presented here. These models show an interesting wiping effect on the liquid zinc, which seems promising for a future experimental pilot design. Figs 8, Refs 9.
American Healthy Homes Survey: A National Study of Residential Pesticides Measured from Floor Wipes.
The U.S. Department of Housing and Urban Development in collaboration with the United States Environmental Protection Agency conducted a survey measuring lead, allergens, and insecticides in a randomly selected nationally representative sample of resodential homes. Multistage sa...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rinehart, R.; Almaguer, D.
1992-05-01
In response to a request from a management representative of the Kansas City, Kansas, Police Department (SIC-9221), an evaluation was undertaken of possible lead (7439921) exposures at the Police Department outdoor firing range. About 200,000 rounds of ammunition were fired at the range each year. Personal breathing zone and area air samples were taken for lead analysis. Surface wipe samples were taken as well along with hand lead concentrations and contamination of clothing. Air sampling revealed that the officers were exposed to 8 hour time weighted average concentrations of airborne lead ranging from nondetectable to 8 micrograms (microg) per cubicmore » meter. The general air samples collected ranged from nondetectable to trace levels of contamination. The authors conclude that airborne lead did not exceed evaluation criteria, but dermal, surface and clothing contamination could increase the potential for lead ingestion and lead contamination of automobiles and homes. The authors recommend that efforts be made to reduce the potential spread of lead, and that medical surveillance be instituted for frequent range users and the range master.« less
Bridoux, Maxime C; Schwarzenberg, Adrián; Schramm, Sébastien; Cole, Richard B
2016-08-01
Direct Analysis in Real Time (DART™) high-resolution Orbitrap™ mass spectrometry (HRMS) in combination with Raman microscopy was used for the detailed molecular level characterization of explosives including not only the charge but also the complex matrix of binders, plasticizers, polymers, and other possible organic additives. A total of 15 defused military weapons including grenades, mines, rockets, submunitions, and mortars were examined. Swabs and wipes were used to collect trace (residual) amounts of explosives and their organic constituents from the defused military weapons and micrometer-size explosive particles were transferred using a vacuum suction-impact collection device (vacuum impactor) from wipe and swap samples to an impaction plate made of carbon. The particles deposited on the carbon plate were then characterized using micro-Raman spectroscopy followed by DART-HRMS providing fingerprint signatures of orthogonal nature. The optical microscope of the micro-Raman spectrometer was first used to localize and characterize the explosive charge on the impaction plate which was then targeted for identification by DART-HRMS analysis in both the negative and positive modes. Raman spectra of the explosives TNT, RDX and PETN were acquired from micrometer size particles and characterized by the presence of their characteristic Raman bands obtained directly at the surface of the impaction plate nondestructively without further sample preparation. Negative mode DART-HRMS confirmed the types of charges contained in the weapons (mainly TNT, RDX, HMX, and PETN; either as individual components or as mixtures). These energetic compounds were mainly detected as deprotonated species [M-H](-), or as adduct [M + (35)Cl](-), [M + (37)Cl](-), or [M + NO3](-) anions. Chloride adducts were promoted in the heated DART reagent gas by adding chloroform vapors to the helium stream using an "in-house" delivery method. When the polarity was switched to positive mode, DART-HRMS revealed a very complex distribution of polymeric binders (mainly polyethylene glycols and polypropylene glycols), plasticizers (e.g., dioctyl sebacate, tributyl phosphate), as well as wax-like compounds whose structural features could not be precisely assigned. In positive mode, compounds were identified either as protonated molecules or ammonium adduct species. These results clearly demonstrate the complementarity of micro-Raman microscopy combined with DART-MS. The former technique provides structural information on the type of explosives present at the surface of the sample, whereas the latter provides not only a confirmation of the nature of the explosive charge but also useful additional information regarding the nature of the complex organic matrix of binders, plasticizers, polymers, oils, and potentially other organic additives and contaminants present in the sample. Combining these two techniques provides a powerful tool for the screening, comprehensive characterization, and differentiation of particulate explosive samples for forensic sciences and homeland security applications. Graphical Abstract Comprehensive characterization of explosive particles collected from swipe samples by micro-Raman and DART™-HRMS.
Potential exposures associated with indoor marijuana growing operations.
Martyny, John W; Serrano, Kate A; Schaeffer, Joshua W; Van Dyke, Mike V
2013-01-01
We entered a total of 30 indoor marijuana grow operations (IMGO) with law enforcement investigators in order to determine potential exposures to first responders. Samples for airborne fungal spores, volatile organic compounds, carbon dioxide, carbon monoxide, and delta-9-tetrahydrocannabinol (THC) were obtained as well as the identification of chemicals utilized in the IMGO. The chemicals utilized within the IMGOs were primarily pesticides and fertilizers with none showing high toxicity. Although several of the IMGOs had CO2 enrichment processes involving combustion, CO levels were not elevated. THC levels were identified on surfaces within the IMGOs and on the hands of the investigators. Surface levels ranged from <0.1 μg /100 cm(2) to 2000 μg /100 cm(2) with a geometric mean of 0.37 μg /100 cm(2). THC levels on the hands of officers ranged from <0.10 μg /wipe to 2900 μg /wipe with a geometric mean of 15 μg /wipe. These levels were not considered to be elevated to the point of causing a toxic exposure to responders. A total of 407 fungal spore samples were taken using both slit impactor plates and 400-hole impactors. Both methods identified elevated fungal spore levels, especially during the removal of plants from some of the IMGOs. After plant removal, spore counts increased to levels above 50,000 spores/m(3) with one sample over 500,000 spores/m(3). In addition, we found that there was a shift in species between indoor and outdoor samples with Cladosporium sp. the predominant outdoor species and Penicillium sp. the predominant indoor species. We concluded that the potential increase in fungal spore concentrations associated with the investigation and especially removal of the marijuana plants could potentially expose responders to levels of exposure consistent with those associated with mold remediation processes and that respiratory protection is advisable.
American Healthy Homes Survey: A National Study of Residential Phthalates Measured from Floor Wipes
The United States Environmental Protection Agency (U.S. EPA), in collaboration with the U.S. Department of Housing and Urban Development (HUD), conducted a survey measuring phthalates in randomly selected residential homes throughout the U.S. Multistage sampling with clustering w...
10 CFR 39.13 - Specific licenses for well logging.
Code of Federal Regulations, 2011 CFR
2011-01-01
... applicant will use to demonstrate the logging supervisor's knowledge and understanding of and ability to... and understanding of and ability to comply with the applicant's operating and emergency procedures. (c... performing the analysis; and (3) Pertinent experience of the person who will analyze the wipe samples. ...
Characterization of Dust on Solar Devices in Southern Nevada =
NASA Astrophysics Data System (ADS)
Sylva, Jason R.
Dust can impact the efficiency of solar energy collection devices, and in some arid environments, dust can reduce solar energy efficiency up to 30%. Reducing the impact of dust is therefore critical in the expansion of solar technology throughout regions where solar energy is utilized. Characterization of suspended and settled particulate matter can assist in developing strategies for dust mitigation. With the characterization of suspended and settled particulate in remote, rural, and urban environments, more informed decisions can be made regarding the selection of coating material on solar panels as well as developing cleaning and maintenance procedures. Particulate matter that deposits on a solar surface can potentially interact with solar radiation, precipitation, or even directly with the surface material itself. These interactions could lead to the formation of coatings that reduce/block radiation and/or degrade the integrity of the surface. When you extrapolate these possibilities to a larger scale preliminary characterization of dust will play a vital role when planning the construction of a solar energy facility. A variety of sampling techniques were employed to obtain particulate matter for characterization. These included direct collection of particulates from solar surfaces: via vacuum and wipe sample collection on panels, tacky dot adhesive slides and plain slides that were exposed at different intervals, desert vugs that are natural particulate collectors, as well as high volume air sampling for collection of suspended particulates. High volume air sampling was performed using glass fiber filters and 2 micron stainless steel screens. Direct collection of settled particulates was performed by sampling from solar surfaces, vugs, and by collection on exposed glass surfaces. Collection onto glass surfaces was achieved by setting up a plain microscope slide, tacky dot slides, and panes of glass. The sampling methodology allowed for the collection of samples for analyses using various analytical methods that included Raman microspectroscopy, pyrolysis gas chromatography mass spectrometry, ion chromatography and inductively coupled plasma mass spectrometry. These various methods allow for identification of organic and inorganic components as well the mineral distribution of suspended and settled particulate material. None None None None None
Systemic exposure to PAHs and benzene in firefighters suppressing controlled structure fires.
Fent, Kenneth W; Eisenberg, Judith; Snawder, John; Sammons, Deborah; Pleil, Joachim D; Stiegel, Matthew A; Mueller, Charles; Horn, Gavin P; Dalton, James
2014-08-01
Turnout gear provides protection against dermal exposure to contaminants during firefighting; however, the level of protection is unknown. We explored the dermal contribution to the systemic dose of polycyclic aromatic hydrocarbons (PAHs) and other aromatic hydrocarbons in firefighters during suppression and overhaul of controlled structure burns. The study was organized into two rounds, three controlled burns per round, and five firefighters per burn. The firefighters wore new or laundered turnout gear tested before each burn to ensure lack of PAH contamination. To ensure that any increase in systemic PAH levels after the burn was the result of dermal rather than inhalation exposure, the firefighters did not remove their self-contained breathing apparatus until overhaul was completed and they were >30 m upwind from the burn structure. Specimens were collected before and at intervals after the burn for biomarker analysis. Urine was analyzed for phenanthrene equivalents using enzyme-linked immunosorbent assay and a benzene metabolite (s-phenylmercapturic acid) using liquid chromatography/tandem mass spectrometry; both were adjusted by creatinine. Exhaled breath collected on thermal desorption tubes was analyzed for PAHs and other aromatic hydrocarbons using gas chromatography/mass spectrometry. We collected personal air samples during the burn and skin wipe samples (corn oil medium) on several body sites before and after the burn. The air and wipe samples were analyzed for PAHs using a liquid chromatography with photodiode array detection. We explored possible changes in external exposures or biomarkers over time and the relationships between these variables using non-parametric sign tests and Spearman tests, respectively. We found significantly elevated (P < 0.05) post-exposure breath concentrations of benzene compared with pre-exposure concentrations for both rounds. We also found significantly elevated post-exposure levels of PAHs on the neck compared with pre-exposure levels for round 1. We found statistically significant positive correlations between external exposures (i.e. personal air concentrations of PAHs) and biomarkers (i.e. change in urinary PAH metabolite levels in round 1 and change in breath concentrations of benzene in round 2). The results suggest that firefighters wearing full protective ensembles absorbed combustion products into their bodies. The PAHs most likely entered firefighters' bodies through their skin, with the neck being the primary site of exposure and absorption due to the lower level of dermal protection afforded by hoods. Aromatic hydrocarbons could have been absorbed dermally during firefighting or inhaled during the doffing of gear that was off-gassing contaminants. © The Author 2014. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.
Systemic Exposure to PAHs and Benzene in Firefighters Suppressing Controlled Structure Fires
Fent, Kenneth W.; Eisenberg, Judith; Snawder, John; Sammons, Deborah; Pleil, Joachim D.; Stiegel, Matthew A.; Mueller, Charles; Horn, Gavin P.; Dalton, James
2014-01-01
Turnout gear provides protection against dermal exposure to contaminants during firefighting; however, the level of protection is unknown. We explored the dermal contribution to the systemic dose of polycyclic aromatic hydrocarbons (PAHs) and other aromatic hydrocarbons in firefighters during suppression and overhaul of controlled structure burns. The study was organized into two rounds, three controlled burns per round, and five firefighters per burn. The firefighters wore new or laundered turnout gear tested before each burn to ensure lack of PAH contamination. To ensure that any increase in systemic PAH levels after the burn was the result of dermal rather than inhalation exposure, the firefighters did not remove their self-contained breathing apparatus until overhaul was completed and they were >30 m upwind from the burn structure. Specimens were collected before and at intervals after the burn for biomarker analysis. Urine was analyzed for phenanthrene equivalents using enzyme-linked immunosorbent assay and a benzene metabolite (s-phenylmercapturic acid) using liquid chromatography/tandem mass spectrometry; both were adjusted by creatinine. Exhaled breath collected on thermal desorption tubes was analyzed for PAHs and other aromatic hydrocarbons using gas chromatography/mass spectrometry. We collected personal air samples during the burn and skin wipe samples (corn oil medium) on several body sites before and after the burn. The air and wipe samples were analyzed for PAHs using a liquid chromatography with photodiode array detection. We explored possible changes in external exposures or biomarkers over time and the relationships between these variables using non-parametric sign tests and Spearman tests, respectively. We found significantly elevated (P < 0.05) post-exposure breath concentrations of benzene compared with pre-exposure concentrations for both rounds. We also found significantly elevated post-exposure levels of PAHs on the neck compared with pre-exposure levels for round 1. We found statistically significant positive correlations between external exposures (i.e. personal air concentrations of PAHs) and biomarkers (i.e. change in urinary PAH metabolite levels in round 1 and change in breath concentrations of benzene in round 2). The results suggest that firefighters wearing full protective ensembles absorbed combustion products into their bodies. The PAHs most likely entered firefighters’ bodies through their skin, with the neck being the primary site of exposure and absorption due to the lower level of dermal protection afforded by hoods. Aromatic hydrocarbons could have been absorbed dermally during firefighting or inhaled during the doffing of gear that was off-gassing contaminants. PMID:24906357
10 CFR 39.13 - Specific licenses for well logging.
Code of Federal Regulations, 2010 CFR
2010-01-01
... training; (2) On-the-job training; (3) Annual safety reviews provided by the licensee; (4) Means the... annual inspections of the job performance of each logging supervisor to ensure that the Commission's... performing the analysis; and (3) Pertinent experience of the person who will analyze the wipe samples. ...
Methamphetamine (meth) residues from meth syntheses or habitual meth smoking pose human health hazards. State health departments require remediation of meth labs before properties are sold. NIOSH methods for meth analysis require wipe sampling, extraction, cleanup, solvent excha...
Method 8321B describes procedures for preparation and analysis of solid, aqueous liquid, drinking water and wipe samples using high performance liquid chromatography and mass spectrometry for extractable non-volatile compounds.
10 CFR 39.13 - Specific licenses for well logging.
Code of Federal Regulations, 2013 CFR
2013-01-01
... applicant will use to demonstrate the logging supervisor's knowledge and understanding of and ability to... and understanding of and ability to comply with the applicant's operating and emergency procedures. (c... performing the analysis; and (3) Pertinent experience of the person who will analyze the wipe samples. [52 FR...
10 CFR 39.13 - Specific licenses for well logging.
Code of Federal Regulations, 2012 CFR
2012-01-01
... applicant will use to demonstrate the logging supervisor's knowledge and understanding of and ability to... and understanding of and ability to comply with the applicant's operating and emergency procedures. (c... performing the analysis; and (3) Pertinent experience of the person who will analyze the wipe samples. [52 FR...
10 CFR 39.13 - Specific licenses for well logging.
Code of Federal Regulations, 2014 CFR
2014-01-01
... applicant will use to demonstrate the logging supervisor's knowledge and understanding of and ability to... and understanding of and ability to comply with the applicant's operating and emergency procedures. (c... performing the analysis; and (3) Pertinent experience of the person who will analyze the wipe samples. [52 FR...
Landin, Wendell E; Mun, Greg C; Nims, Raymond W; Harbell, John W
2007-09-01
The cytosensor microphysiometer (mu phi) was investigated as a rapid, relatively inexpensive test to predict performance of skin cleansing wipes on the human 21-day cumulative irritation patch test (21CIPT). It indirectly measures metabolic rate changes in L929 cells as a function of test article dose, by measuring the acidification rate in a low-buffer medium. The dose producing a 50% reduction in metabolic rate (MRD50), relative to the baseline rate, is used as a measure of toxicity. The acute toxicity of the mu phi assay can be compared to the chronic toxicity of the 21CIPT, which is based largely on the exposure of test agents to the epidermal cells, resulting in damage and penetration of the stratum corneum leading to cell toxicity. Two series of surfactant-based cleansing wipe products were tested via the mu phi assay and 21CIPT. The first series, consisting of 20 products, was used to determine a prediction model. The second series of 38 products consisted of routine product development formulas or marketed products. Comparing the results from both tests, samples with an MRD50 greater than 50 mg/ml provided a 21CIPT score consistent with a product that performs satisfactorily in the market. When the MRD50 was greater than 78 mg/ml, the 21CIPT score was usually zero. The mu phi may be more sensitive than the 21CIPT for ranking minimally irritating materials. The mu phi assay is useful as a screen for predicting the performance of a wet wipes formula on the 21CIPT, and concurrently reduces the use of animals for safety testing in a product development program for cleansing wipes.
Li, Dan; Zhu, Qingxia; Lv, Diya; Zheng, Binxing; Liu, Yanhua; Chai, Yifeng; Lu, Feng
2015-08-01
By using a silver nanoparticle wiper as a surface-enhanced Raman scattering substrate, a highly sensitive, convenient, and rapid platform for detecting dye adulteration of medicinal herbs was obtained. Commercially available filter paper was functionalized with silver nanoparticles to transform it into the flexible wiper. This device was found to collect dye molecules with unprecedented ease. Experiments were performed to optimize various factors such as the type of wiper used, the wetting reagent, and the wetting/wiping mode and time. Excellent wiper performance was observed in the detection of the simulated adulteration of samples with dyes at various concentrations. The limits of detection for nine dyes, including 10(-6) g/mL for malachite green, 10(-7) g/mL for Rhodamine 6G, and 5 × 10(-8) g/mL for methylene blue, were discerned. The results of this investigation show that this proposed method is potentially highly advantageous for field-based applications. Graphical Abstract Schematic diagram illustrating the fabrication of the paper-based SERS substrate, sample collection process on a herb and SERS examination with the portable Raman spectrometer.
Assessment of human exposure to polychlorinated dibenzofurans and dioxins.
Rappe, C; Nygren, M; Marklund, S; Keller, L O; Bergqvist, P A; Hansson, M
1985-01-01
Fires, explosions and other accidents in polychlorinated biphenyl (PCB)-filled equipment can result in possible exposure of firemen, cleaning personnel and regular workers. Inhalation, dermal exposure and ingestion are the possible routes of exposure. An indirect assessment of the exposure can be made by analyses of wipes, air and water samples and clothes. A direct assessment of exposure can be made by analyses of blood samples, adipose and other tissue samples, feces and bile. PMID:4029099
Muramatsu, Keita; Matsuo, Koichiro; Kawai, Yusuke; Yamamoto, Tsukasa; Hara, Yoshitaka; Shimomura, Yasuyo; Yamashita, Chizuru; Nishida, Osamu
2018-06-26
Endotracheal intubation of critically ill patients increases the risk of aspiration pneumonia, which can be reduced by regular oral care. However, the rinsing of the residual oral contaminants after mechanical cleaning carries the risk of aspirating the residue during the intubation period. Removing the contaminants by wiping with mouth wipes could be an alternative to rinsing with water because of no additional fluid. This study tested: (i) the amount of oral bacteria during endotracheal intubation and after extubation; and (ii) the changes in the bacterial count during oral care procedures. Thirty-five mechanically ventilated patients in the intensive care unit were enrolled. The amount of bacteria on the dorsal tongue surface was counted before and following oral care and then after the elimination of contaminants either by rinsing with water and suctioning or by wiping with mouth wipes. The oral bacterial amount was compared statistically between the intubation and extubation status and among set time points during the oral care procedure. The oral bacterial count was significantly decreased after extubation. During the oral care procedure, the oral bacterial amount was significantly lower after eliminating the contaminants either by rinsing or wiping, with no remarkable difference between the elimination techniques. The findings suggest that the oral bacterial amount is elevated during endotracheal intubation, which could increase the risk of aspiration pneumonia. The significant reduction in the bacterial count by wiping indicates that it might be a suitable alternative to rinsing for mechanically ventilated patients. © 2018 Japan Academy of Nursing Science.
Saleem, S; Rouse, DJ; McClure, EM; Reza, T; Yahya, Y; Memon, IA; Zaidi, Anita; Khan, NH; Memon, G; Soomro, N; Pasha, O; Wright, LL; Moore, J; Goldenberg, RL
2013-01-01
Background Sepsis is a leading cause of perinatal death in developing countries. Vaginal organisms acquired during labor play a significant role. Prior studies suggest that chlorhexidine wiping of the maternal vagina during labor and of the neonate may reduce peripartum infections. Methods We performed a placebo-controlled, randomized trial of chlorhexidine vaginal and neonatal wipes to reduce neonatal sepsis and mortality in three hospitals in Pakistan. The primary study outcome was a composite of neonatal sepsis or 7-day perinatal mortality. Findings From 2005 to 2008, 5,008 laboring women and their neonates were randomized to receive either chlorhexidine wipes (n = 2,505) or wipes with a saline placebo (n = 2,503). The primary outcome was similar in the chlorhexidine and control groups, (3.1% vs. 3.4%; RR 0.91, 95% CI 0.67, 1.24), as was the composite rate of neonatal sepsis or 28-day perinatal mortality, (3.8% vs. 3.9%, RR 0.96, 95% CI 0.73, 1.27). At day 7, the chlorhexidine group had a lower rate of neonatal skin infection. (3.3 vs. 8.2%, p<0.0001) With the exception of less frequent 7-day hospitalization in the chlorhexidine group, there were no significant differences in maternal outcomes between the groups. Interpretation This trial provides evidence that the use of maternal chlorhexidine vaginal wipes during labor and neonatal chlorhexidine wipes does not reduce maternal and perinatal mortality or neonatal sepsis. The finding of reduced superficial skin infections on day 7 without change in sepsis or mortality suggests that this difference, although statistically significant, may not be of major importance. Trial Registration: Clinicaltrials.gov: NCT00121394 PMID:20502294
EPA conducted a study to evaluate the effect of coatings on dislodgeable arsenic, chromium, and copper residues on the surfaces of chromated copper arsenate (CAA) treated wood. Dislodgeable CCA, determined by wipe sampling the wood surfaces, was the primary evaluation criterion f...
40 CFR 761.125 - Requirements for PCB spill cleanup.
Code of Federal Regulations, 2012 CFR
2012-07-01
...) Additional pre- or post-cleanup sampling. (B) The estimated cost of the cleanup by man-hours, dollars, or... section are designed to be consistent with existing reporting requirements to the extent possible so as to...) by standard commercial wipe tests. (ii) All soil within the spill area (i.e., visible traces of soil...
40 CFR 761.125 - Requirements for PCB spill cleanup.
Code of Federal Regulations, 2014 CFR
2014-07-01
...) Additional pre- or post-cleanup sampling. (B) The estimated cost of the cleanup by man-hours, dollars, or... section are designed to be consistent with existing reporting requirements to the extent possible so as to...) by standard commercial wipe tests. (ii) All soil within the spill area (i.e., visible traces of soil...
40 CFR 761.125 - Requirements for PCB spill cleanup.
Code of Federal Regulations, 2011 CFR
2011-07-01
...) Additional pre- or post-cleanup sampling. (B) The estimated cost of the cleanup by man-hours, dollars, or... section are designed to be consistent with existing reporting requirements to the extent possible so as to...) by standard commercial wipe tests. (ii) All soil within the spill area (i.e., visible traces of soil...
40 CFR 761.125 - Requirements for PCB spill cleanup.
Code of Federal Regulations, 2013 CFR
2013-07-01
...) Additional pre- or post-cleanup sampling. (B) The estimated cost of the cleanup by man-hours, dollars, or... section are designed to be consistent with existing reporting requirements to the extent possible so as to...) by standard commercial wipe tests. (ii) All soil within the spill area (i.e., visible traces of soil...
40 CFR 761.125 - Requirements for PCB spill cleanup.
Code of Federal Regulations, 2010 CFR
2010-07-01
...) Additional pre- or post-cleanup sampling. (B) The estimated cost of the cleanup by man-hours, dollars, or... section are designed to be consistent with existing reporting requirements to the extent possible so as to...) by standard commercial wipe tests. (ii) All soil within the spill area (i.e., visible traces of soil...
Tebbutt, G. M.
1991-01-01
The relationship between visual inspections carried out by environmental health officers and microbiological examination was studied in 89 restaurants. Using 30 variables a standardized inspection procedure was developed and each of the premises was assessed in six main areas-structure and design, cleaning and cleanliness, personal hygiene, risk of contamination, temperature control, and training and knowledge about food hygiene. Selected foods and specimens from hands, surfaces, and wiping cloths were examined. There were significant associations between all six areas of the inspections. The structure and design were significantly related to the combined score from all the other areas (P less than 0.001). There were no highly significant associations between microbiological examination and visual assessments. The microbial contamination of wiping cloths, however, was related to the cleaning and cleanliness (P = 0.005). Microbial sampling provided additional information to inspections and was a valuable aid. Further development of this risk-assessment approach could provide an effective system for monitoring potential health risks in high-risk food premises. PMID:1936161
The purpose of this SOP is to describe the acid digestion of soil, house dust, air filter, and surface or dermal wipe samples for analysis using inductively coupled plasma atomic emissions spectrometry (ICP-AES) and/or graphite furnace atomic absorption spectrometry (GFAAS) or fl...
A simple lead dust fall method predicts children's blood lead level: New evidence from Australia.
Gulson, Brian; Taylor, Alan
2017-11-01
We have measured dust fall accumulation in petri dishes (PDD) collected 6 monthly from inside residences in Sydney urban area, New South Wales, Australia as part of a 5-year longitudinal study to determine environmental associations, including soil. with blood lead (PbB) levels. The Pb loading in the dishes (n = 706) had geometric means (GM) of 24µg/m 2 /30d, a median value of 22µg/m 2 /30d with a range from 0.2 to 11,390µg/m 2 /30d. Observed geometric mean PbB was 2.4µg/dL at ages 2-3 years. Regression analyses showed a statistically significant relationship between predicted PbB and PDD. The predicted PbB values from dust in our study are consistent with similar analyses from the US in which floor dust was collected by wipes. Predicted PbB values from PDD indicate that an increase in PDD of about 100µg/m 2 /30d would increase PbB by about 1.5µg/dL or a doubling PbB at the low levels currently observed in many countries. Predicted PbB values from soil indicate that a change from 0 to 1000mg Pb/kg results in an increase of 1.7µg/dL in PbB, consistent with earlier investigations. Blood Pb levels can be predicted from dust fall accumulation (and soil) in cases where blood sampling is not always possible, especially in young children. Petri dish loading data could provide an alternative or complementary "action level" at about 100µg Pb/m 2 /30 days, similar to the suggested level of about 110µg Pb/m 2 for surface wipes, for use in monitoring activities such as housing rehabilitation, demolition or soil resuspension. Copyright © 2017 Elsevier Inc. All rights reserved.
49 CFR 393.78 - Windshield wiping and washing systems.
Code of Federal Regulations, 2010 CFR
2010-10-01
... wipers, shall have the wiper system constructed and maintained such that the performance of the wipers... operations. Windshield wiping and washing systems need not be in working condition while a commercial motor...
Experimental Characterization of the Jet Wiping Process
NASA Astrophysics Data System (ADS)
Mendez, Miguel Alfonso; Enache, Adriana; Gosset, Anne; Buchlin, Jean-Marie
2018-06-01
This paper presents an experimental characterization of the jet wiping process, used in continuous coating applications to control the thickness of a liquid coat using an impinging gas jet. Time Resolved Particle Image Velocimetry (TR-PIV) is used to characterize the impinging gas flow, while an automatic interface detection algorithm is developed to track the liquid interface at the impact. The study of the flow interaction is combined with time resolved 3D thickness measurements of the liquid film remaining after the wiping, via Time Resolved Light Absorption (TR-LAbs). The simultaneous frequency analysis of liquid and gas flows allows to correlate their respective instability, provide an experimental data set for the validation of numerical studies and allows for formulating a working hypothesis on the origin of the coat non-uniformity encountered in many jet wiping processes.
Sarmaga, Don; DuBois, Jeffrey A; Lyon, Martha E
2011-01-01
Background Off-meter dosed photometric glucose-oxidase-based glucose meters have been reported to be susceptible to interference by hydrogen-peroxide-based disinfecting agents. The objective of this study was to determine if a single application of hydrogen-peroxide-containing Accel® wipe to disinfect an on-meter dosed amperometric glucose-oxidase-based glucose meter will influence its performance. Method The performance of five on-meter dosed amperometric glucose-oxidase-based glucose meters was determined before and after disinfecting the devices with a single application of either CaviWipes® (14.3% isopropanol and 0.23% diisobutyl-phenoxy-ethoxyethyl dimethyl benzyl ammonium chloride) or Accel (0.5% hydrogen peroxide) wipes. Replicate glucose measurements were conducted before disinfecting the devices, immediately after disinfecting, and then 1 and 2 min postdisinfecting, with measurements in triplicate. Analysis was sequentially completed for five different meters. Results were analyzed by a two-way analysis of variance (Analyze-it software). Results No clinical (<0.3 mmol/liter) or statistical differences (p > .05) in glucose concentration were detected when the on-meter dosed amperometric glucose-oxidase-based glucose meters were disinfected with either CaviWipes or Accel wipes and measured immediately or 1 or 2 min postdisinfecting. No clinically significant difference in glucose concentration was detected between meters (<0.3 mmol/liter). Conclusion The on-meter dosed glucose oxidase amperometric-based glucose meters are not analytically susceptible to interference by a single application of hydrogen-peroxide-containing Accel disinfectant wipes. PMID:22226263
Sarmaga, Don; Dubois, Jeffrey A; Lyon, Martha E
2011-11-01
Off-meter dosed photometric glucose-oxidase-based glucose meters have been reported to be susceptible to interference by hydrogen-peroxide-based disinfecting agents. The objective of this study was to determine if a single application of hydrogen-peroxide-containing Accel® wipe to disinfect an on-meter dosed amperometric glucose-oxidase-based glucose meter will influence its performance. The performance of five on-meter dosed amperometric glucose-oxidase-based glucose meters was determined before and after disinfecting the devices with a single application of either CaviWipes® (14.3% isopropanol and 0.23% diisobutyl-phenoxy-ethoxyethyl dimethyl benzyl ammonium chloride) or Accel (0.5% hydrogen peroxide) wipes. Replicate glucose measurements were conducted before disinfecting the devices, immediately after disinfecting, and then 1 and 2 min postdisinfecting, with measurements in triplicate. Analysis was sequentially completed for five different meters. Results were analyzed by a two-way analysis of variance (Analyze-it software). No clinical (<0.3 mmol/liter) or statistical differences (p > .05) in glucose concentration were detected when the on-meter dosed amperometric glucose-oxidase-based glucose meters were disinfected with either CaviWipes or Accel wipes and measured immediately or 1 or 2 min postdisinfecting. No clinically significant difference in glucose concentration was detected between meters (<0.3 mmol/liter). The on-meter dosed glucose oxidase amperometric-based glucose meters are not analytically susceptible to interference by a single application of hydrogen-peroxide-containing Accel disinfectant wipes. © 2011 Diabetes Technology Society.
Capillary microextraction: A new method for sampling methamphetamine vapour.
Nair, M V; Miskelly, G M
2016-11-01
Clandestine laboratories pose a serious health risk to first responders, investigators, decontamination companies, and the public who may be inadvertently exposed to methamphetamine and other chemicals used in its manufacture. Therefore there is an urgent need for reliable methods to detect and measure methamphetamine at such sites. The most common method for determining methamphetamine contamination at former clandestine laboratory sites is selected surface wipe sampling, followed by analysis with gas chromatography-mass spectrometry (GC-MS). We are investigating the use of sampling for methamphetamine vapour to complement such wipe sampling. In this study, we report the use of capillary microextraction (CME) devices for sampling airborne methamphetamine, and compare their sampling efficiency with a previously reported dynamic SPME method. The CME devices consisted of PDMS-coated glass filter strips inside a glass tube. The devices were used to dynamically sample methamphetamine vapour in the range of 0.42-4.2μgm -3 , generated by a custom-built vapour dosing system, for 1-15min, and methamphetamine was analysed using a GC-MS fitted with a ChromatoProbe thermal desorption unit. The devices showed good reproducibility (RSD<15%), and a curvilinear pre-equilibrium relationship between sampling times and peak area, which can be utilised for calibration. Under identical sampling conditions, the CME devices were approximately 30 times more sensitive than the dynamic SPME method. The CME devices could be stored for up to 3days after sampling prior to analysis. Consecutive sampling of methamphetamine and its isotopic substitute, d-9 methamphetamine showed no competitive displacement. This suggests that CME devices, pre-loaded with an internal standard, could be a feasible method for sampling airborne methamphetamine at former clandestine laboratories. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Brominated Flame Retardants and Organophosphate Esters in Preschool Dust and Children's Hand Wipes.
Larsson, Kristin; de Wit, Cynthia A; Sellström, Ulla; Sahlström, Leena; Lindh, Christian H; Berglund, Marika
2018-04-17
Children spend a considerable part of their day in preschool, where they may be exposed to hazardous chemicals in indoor dust. In this study, brominated flame retardants (BFRs) and organophosphate esters (OPEs) were analyzed in preschool dust ( n = 100) and children's hand wipe samples ( n = 100), and diphenyl phosphate (DPHP) was analyzed in urine ( n = 113). Here we assessed children's exposure via dust, identified predictors for chemicals in dust, and studied correlations between different exposure measures. The most abundant BFRs in dust were decabromodiphenyl ether (BDE-209) and decabromodiphenyl ethane (DBDPE) found at median levels of 270 and 110 ng/g dust, respectively. Tris(2-butoxyethyl) phosphate (TBOEP) was the most abundant OPE, found at a median level of 79 000 ng/g dust. For all OPEs and some BFRs, there were significant correlations between the levels in dust and hand wipes. In addition, triphenyl phosphate (TPHP) in preschool dust was significantly correlated with the corresponding metabolite DPHP in children's urine. The levels of pentaBDEs in dust were higher in older preschools compared with newer, whereas levels of DBDPE were higher in newer preschools. Children's estimated intakes of individual BFRs and OPEs via preschool dust were below available health-based reference values. However, there are uncertainties about the potential health effects of some emerging BFRs and OPEs.
Salin, J T; Salkinoja-Salonen, M; Salin, P J; Nelo, K; Holma, T; Ohtonen, P; Syrjälä, H
2017-04-01
Indoor microbial toxicity is suspected to cause some building-related symptoms, but supporting epidemiological data are lacking. We examined whether the in vitro toxicity of indoor samples from school buildings was associated with work-related health symptoms (building-related symptoms, BRS). Administrators of the Helsinki City Real Estate Department selected 15 schools for the study, and a questionnaire on symptoms connected to work was sent to the teachers in the selected schools for voluntary completion. The cellular toxicity of classroom samples was determined by testing substances extracted from wiped indoor dust and by testing microbial biomass that was cultured on fallout plates. Boar sperm cells were used as indicator cells, and motility loss was the indicator for toxic effects. The effects were expressed as the half maximal effective concentration (EC 50 ) at which >50% of the exposed boar sperm cells were immobile compared to vehicle control. Completed symptom questionnaires were received from 232 teachers [median age, 43 years; 190 (82.3%) women] with a median time of 6 years working at their school. Samples from their classrooms were available and were assessed for cellular toxicity. The Poisson regression model showed that the impact of extracts of surface-wiped school classroom dust on teacher work-related BRS was 2.8-fold (95% CI: 1.6-4.9) higher in classrooms with a toxic threshold EC 50 of 6µgml -1 versus classrooms with insignificant EC 50 values (EC 50 >50µgml -1 ); P<0.001. The number of symptoms that were alleviated during vacation was higher in school classrooms with high sperm toxicity compared to less toxic sites; the RR was 1.9 (95% CI: 1.1-3.3, P=0.03) for wiped dust extracts. Teachers working in classrooms where the samples showed high sperm toxicity had more BRS. The boar sperm cell motility inhibition assay appears promising as a tool for demonstrating the presence of indoor substances associated with BRS. Copyright © 2017 Elsevier Inc. All rights reserved.
EPA is approximately 20 months into a project to evaluate the performance of wood coatings as a way to prevent arsenic, chromium and copper exposure from the surfaces of CCA treated wood. Potential dermal exposure, as measured by wipe sampling dislodgeable CCA chemical from wood ...
The purpose of this SOP is to describe the methods used for detection and quantification by gas chromatography electron capture detector (GC/ECD) of pesticides in a variety of matrices, including air, house dust, soil, handwipes, and surface wipes. Other SOP's detail the extract...
The purpose of this SOP is to describe the general procedures to be followed for cleaning glassware used in preparing and analyzing soil, house dust, air filter, surface wipe, or dermal wash samples for inorganic metals. This procedure was followed to ensure consistent data retr...
Yu, JiaDe; Treat, James; Chaney, Keri; Brod, Bruce
2016-01-01
Allergic contact dermatitis in young children may be an under-recognized cause of perineal dermatitis. The diapered infant skin is uniquely susceptible to allergic contact dermatitis because of more permeable neonatal skin, a moist environment, frequent contact with irritants and resultant skin barrier breakdown, and exposure to topical products such as diaper wipes, diaper preparations, and disposable diapers. To our knowledge, potential allergens in these products have not been thoroughly catalogued or studied. We explore and review potential allergenic ingredients in diaper wipes, topical diaper preparations, and disposable diapers. We analyzed 63 diaper wipes, 41 topical diaper preparations, and the 3 top selling diaper brands available from two of the largest retailers in the United States. Each potential allergen is discussed, and epidemiologic studies of rates of sensitization to potential allergens in children are also reported. Botanical extracts, including members of the Compositae family, were the most commonly represented potential allergen in both diaper wipes and topical preparations. Other potential allergens identified with high frequency include α-tocopherol, fragrances, propylene glycol, parabens, iodopropynyl butylcarbamate, and lanolin. Frequent culprits such as formaldehyde releasers and methylchloroisothiazolinone/methylisothiazolinone were not prevalent in our analyzed products.
2007-08-01
Characterization (OHM 1998). From the plot, it is clear that the HEU dominates DU in the overall isotopic characteristic. Among the three uranium ... isotopes , 234U comprised about 90 % of the total activity, including naturally-occurring background sources. However, in comparison to the WGP, uranium ...listed for a few sampling locations that had isotopic plutonium analysis of wipe samples. Figure A-19 contains a scatterplot of the paired Table 4-13
Field Measurements of Inadvertent Ingestion Exposure to Metals.
Gorman Ng, Melanie; MacCalman, Laura; Semple, Sean; van Tongeren, Martie
2017-11-10
The determinants of inadvertent occupational ingestion exposure are poorly understood, largely due to a lack of available exposure measurement data. In this study, perioral exposure wipes were used as a surrogate for inadvertent ingestion exposure to measure exposure to eight metals (chromium, nickel, aluminium, cobalt, lead, arsenic, manganese, and tin) among 38 workers at 5 work sites in the UK. This work was done alongside a previously reported observational study of hand/object-to-mouth contact frequency. Systematic wipes of the perioral area, and of both hands were taken with proprietary cellulose wipes pre-moistened with deionized water. Measurements were taken at the beginning, middle and end of the shift. Mixed-effect models of exposure measurements were built with area of skin sampled, time during shift, and job group entered as fixed effects and worker identification as a random effect. Linear regression modelling was used to study the effect of hand/object-to-mouth contact frequency on perioral exposure, adjusting for the measured exposure on the hand and observed respirator use. Hand and perioral exposure measurements were correlated with one another (r = 0.79) but mass per unit area exposure was significantly higher on the perioral area than on the hands for seven of the metals (at P < 0.05). There were no significant differences between measurements taken at the middle or the end of the shift for five of the metals suggesting that dermal loading may remain relatively constant for much of the workday. This applies to both hand and perioral measurements. In linear regression modelling there was no relationship between hand/object-to-mouth contact frequency and perioral exposure, but hand exposure was significantly positively related to perioral exposure and workers who used respirators had significantly higher perioral exposure than those who did not. The results suggest the levels of exposure on the hand and respirator use are important determinants of potential inadvertent ingestion exposure. The results did not demonstrate a relationship between perioral exposure and hand-to-mouth contact frequency. Perioral wipe sampling may be a useful surrogate measure for exposure by the inadvertent ingestion route, but further research is required to confirm the link between perioral levels and actual exposure, measured using biological monitoring. © The Author 2017. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.
Lei, Hao; Jones, Rachael M; Li, Yuguo
2017-01-18
Cleaning of environmental surfaces in hospitals is important for the control of methicillin-resistant Staphylococcus aureus (MRSA) and other hospital-acquired infections transmitted by the contact route. Guidance regarding the best approaches for cleaning, however, is limited. In this study, a mathematical model based on ordinary differential equations was constructed to study MRSA concentration dynamics on high-touch and low-touch surfaces, and on the hands and noses of two patients (in two hospitals rooms) and a health care worker in a hypothetical hospital environment. Two cleaning interventions - whole room cleaning and wipe cleaning of touched surfaces - were considered. The performance of the cleaning interventions was indicated by a reduction in MRSA on the nose of a susceptible patient, relative to no intervention. Whole room cleaning just before first patient care activities of the day was more effective than whole room cleaning at other times, but even with 100% efficiency, whole room cleaning only reduced the number of MRSA transmitted to the susceptible patient by 54%. Frequent wipe cleaning of touched surfaces was shown to be more effective that whole room cleaning because surfaces are rapidly re-contaminated with MRSA after cleaning. Wipe cleaning high-touch surfaces was more effective than wipe cleaning low-touch surfaces for the same frequency of cleaning. For low wipe cleaning frequency (≤3 times per hour), high-touch surfaces should be targeted, but for high wipe cleaning frequency (>3 times per hour), cleaning should target high- and low-touch surfaces in proportion to the surface touch frequency. This study reproduces the observations from a field study of room cleaning, which provides support for the validity of our findings. Daily whole room cleaning, even with 100% cleaning efficiency, provides limited reduction in the number of MRSA transmitted to susceptible patients via the contact route; and should be supplemented with frequent targeted cleaning of high-touch surfaces, such as by a wipe or cloth containing disinfectant.
United States Air Force Wipe Solvent Testing
NASA Technical Reports Server (NTRS)
Hornung, Steven D.; Beeson, Harold D.
2000-01-01
The Wright-Patterson Air Force Base (WPAFB), as part of the Air Force Material Command, requested that NASA Johnson Space Center (JSC) White Sands Test Facility (WSTF) conduct testing and analyses in support of the United States Air Force Wipe Solvent Development Project. The purpose of the wipe solvent project is to develop an alternative to be used by Air Force flight line and maintenance personnel for the wipe cleaning of oxygen equipment. This report provides material compatibility, liquid oxygen (LOX) mechanical impact, autogenous ignition temperature (AIT), and gauge cleaning test data for some of the currently available solvents that may be used to replace CFC-113 and methyl chloroform. It provides data from previous WSTF test programs sponsored by the Naval Sea Systems Command, the Kennedy Space Center, and other NASA programs for the purpose of assisting WP AFB in identifying the best alternative solvents for validation testing.
Development, validation and testing of a skin sampling method for assessment of metal exposure.
Erfani, Behnaz; Midander, Klara; Lidén, Carola; Julander, Anneli
2017-07-01
Nickel, cobalt and chromium are frequent skin sensitizers. Skin exposure results in eczema in sensitized individuals, the risk being related to the skin dose. To develop a self-sampling method for quantification of skin exposure to metals, to validate the method, and to assess its feasibility. Defined metal doses (0.01-5 µg) were applied to the fingers of 5 participants. Skin areas (2 cm 2 ) were sampled with 1% HNO 3 , either as 0.1 ml on a swab, or as 0.5 ml on a wipe. Furthermore, 17 participants performed self-sampling by swab after 2 h of leisure activity. Samples were extracted in 1% HNO 3 and analysed by inductively coupled plasma mass spectrometry. The sampling efficiency by swab was 46%, as compared with 93% for acid wipe sampling, for all tested doses. Most metal from the skin dose was detected in the first swab (33-43%). Despite lower sampling efficiency by swab, skin doses of metals following 2 h of leisure activity without hand washing were quantified in all participants, and ranged from 0.0016 to 0.15 µg/cm 2 , from 0.00014 to -0.0020 µg/cm 2 and from 0.00048 to -0.027 µg/cm 2 for nickel, cobalt, and chromium, respectively. The results indicate a future potential of skin sampling by swab to detect and monitor metals on skin by self-sampling. This will contribute to better knowledge of metal skin exposure among dermatitis patients, workers, and the general population. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Liao, Chunyang; Kannan, Kurunthachalam
2014-03-15
Parabens (alkyl esters of p-hydroxybenzoic acid) are widely used as antimicrobial preservatives in personal care products, pharmaceuticals, and foodstuffs. Although parabens have been reported to be used as antimicrobials in certain types of papers (e.g., wet sanitary or hygiene wipes), little is known about the occurrence of these compounds in paper products. In this study, we determined the concentrations of six paraben analogs, methyl (MeP), ethyl (EtP), propyl (PrP), butyl (BuP), benzyl (BzP), and heptyl parabens (HepP), in 253 paper products divided into 18 categories, using liquid chromatography-tandem mass spectrometry (LC-MS/MS). At least one of the six parabens was detected in almost all (detection rate: 98%) paper samples, and the total concentrations (∑PBs; sum of six parabens) ranged from 1.85 to 3,220,000 ng/g (geometric mean (GM): 103; median: 55.1 ng/g). Sanitary wipes contained very high concentrations of ∑PBs (GM: 8300 ng/g). Paper currencies, tickets, business cards, food cartons, flyers, and newspapers contained notable concentrations of ∑PBs, and the GM concentrations in these paper categories were on the order of a few tens to thousands of nanograms per gram. One source of parabens in paper products is the use of these chemicals as antifungal agents. MeP and PrP were the predominant analogs, accounting for approximately 62% and 16% of the total concentrations of parabens, respectively. On the basis of measured concentrations and frequency of handling of paper products, we estimated the daily intake (EDI) of parabens through dermal absorption. The GM and 95th percentile EDI values were 6.31 and 2050 ng/day, respectively, for the general population. Among the paper categories analyzed, sanitary wipes contributed to the majority (>90%) of the exposures. Copyright © 2013 Elsevier B.V. All rights reserved.
Residual Viral and Bacterial Contamination of Surfaces after Cleaning and Disinfection
Tuladhar, Era; Hazeleger, Wilma C.; Koopmans, Marion; Zwietering, Marcel H.; Beumer, Rijkelt R.
2012-01-01
Environmental surfaces contaminated with pathogens can be sources of indirect transmission, and cleaning and disinfection are common interventions focused on reducing contamination levels. We determined the efficacy of cleaning and disinfection procedures for reducing contamination by noroviruses, rotavirus, poliovirus, parechovirus, adenovirus, influenza virus, Staphylococcus aureus, and Salmonella enterica from artificially contaminated stainless steel surfaces. After a single wipe with water, liquid soap, or 250-ppm free chlorine solution, the numbers of infective viruses and bacteria were reduced by 1 log10 for poliovirus and close to 4 log10 for influenza virus. There was no significant difference in residual contamination levels after wiping with water, liquid soap, or 250-ppm chlorine solution. When a single wipe with liquid soap was followed by a second wipe using 250- or 1,000-ppm chlorine, an extra 1- to 3-log10 reduction was achieved, and except for rotavirus and norovirus genogroup I, no significant additional effect of 1,000 ppm compared to 250 ppm was found. A reduced correlation between reduction in PCR units (PCRU) and reduction in infectious particles suggests that at least part of the reduction achieved in the second step is due to inactivation instead of removal alone. We used data on infectious doses and transfer efficiencies to estimate a target level to which the residual contamination should be reduced and found that a single wipe with liquid soap followed by a wipe with 250-ppm free chlorine solution was sufficient to reduce the residual contamination to below the target level for most of the pathogens tested. PMID:22941071
Residual viral and bacterial contamination of surfaces after cleaning and disinfection.
Tuladhar, Era; Hazeleger, Wilma C; Koopmans, Marion; Zwietering, Marcel H; Beumer, Rijkelt R; Duizer, Erwin
2012-11-01
Environmental surfaces contaminated with pathogens can be sources of indirect transmission, and cleaning and disinfection are common interventions focused on reducing contamination levels. We determined the efficacy of cleaning and disinfection procedures for reducing contamination by noroviruses, rotavirus, poliovirus, parechovirus, adenovirus, influenza virus, Staphylococcus aureus, and Salmonella enterica from artificially contaminated stainless steel surfaces. After a single wipe with water, liquid soap, or 250-ppm free chlorine solution, the numbers of infective viruses and bacteria were reduced by 1 log(10) for poliovirus and close to 4 log(10) for influenza virus. There was no significant difference in residual contamination levels after wiping with water, liquid soap, or 250-ppm chlorine solution. When a single wipe with liquid soap was followed by a second wipe using 250- or 1,000-ppm chlorine, an extra 1- to 3-log(10) reduction was achieved, and except for rotavirus and norovirus genogroup I, no significant additional effect of 1,000 ppm compared to 250 ppm was found. A reduced correlation between reduction in PCR units (PCRU) and reduction in infectious particles suggests that at least part of the reduction achieved in the second step is due to inactivation instead of removal alone. We used data on infectious doses and transfer efficiencies to estimate a target level to which the residual contamination should be reduced and found that a single wipe with liquid soap followed by a wipe with 250-ppm free chlorine solution was sufficient to reduce the residual contamination to below the target level for most of the pathogens tested.
Moorman, William J; Reutman, Susan S; Shaw, Peter B; Blade, Leo Michael; Marlow, David; Vesper, Hubert; Clark, John C; Schrader, Steven M
2012-01-01
The aim of this study was to evaluate biomarkers of acrylamide exposure, including hemoglobin adducts and urinary metabolites in acrylamide production workers. Biomarkers are integrated measures of the internal dose, and it is total acrylamide dose from all routes and sources that may present health risks. Workers from three companies were studied. Workers potentially exposed to acrylamide monomer wore personal breathing-zone air samplers. Air samples and surface-wipe samples were collected and analyzed for acrylamide. General-area air samples were collected in chemical processing units and control rooms. Hemoglobin adducts were isolated from ethylenediamine teraacetic acid (EDTA)-whole blood, and adducts of acrylamide and glycidamide, at the N-terminal valines of hemoglobin, were cleaved from the protein chain by use of a modified Edman reaction. Full work-shift, personal breathing zone, and general-area air samples were collected and analyzed for particulate and acrylamide monomer vapor. The highest general-area concentration of acrylamide vapor was 350 μg/cm(3) in monomer production. Personal breathing zone and general-area concentrations of acrylamide vapor were found to be highest in monomer production operations, and lower levels were in the polymer production operations. Adduct levels varied widely among workers, with the highest in workers in the monomer and polymer production areas. The acrylamide adduct range was 15-1884 pmol/g; glycidamide adducts ranged from 17.8 to 1376 p/mol/g. The highest acrylamide and glycidamide adduct levels were found among monomer production process operators. The primary urinary metabolite N-acetyl-S-(2-carbamoylethyl) cysteine (NACEC) ranged from the limit of detection to 15.4 μg/ml. Correlation of workplace exposure and sentinel health effects is needed to determine and control safe levels of exposure for regulatory standards.
The purpose of this SOP is to describe the general procedures to be followed for cleaning glassware used in preparing and analyzing soil, house dust, air filter, surface wipe, or dermal wash samples for inorganic metals. This procedure was followed to ensure consistent data retr...
Middle School Girls Sample "Hard Hat" Life at Construction Camp
ERIC Educational Resources Information Center
Brown, Aneeta
2013-01-01
On a Monday morning in July, a fan as tall as a refrigerator churned noisily in the cavernous classroom. As the outdoor temperature crept higher, teenage girls wearing hardhats and safety glasses wiped perspiration and sawdust from their faces. This was not a field trip. This was the second hour of camp at Ranken Technical College in St. Louis,…
This is a regulation page for the final rule EPA issued on July 31, 2013 that modifies the hazardous waste management regulations for solvent-contaminated wipes under the Resource Conservation and Recovery Act (RCRA).
False-Negative Rate and Recovery Efficiency Performance of a Validated Sponge Wipe Sampling Method
Piepel, Greg F.; Boucher, Raymond; Tezak, Matt; Amidan, Brett G.; Einfeld, Wayne
2012-01-01
Recovery of spores from environmental surfaces varies due to sampling and analysis methods, spore size and characteristics, surface materials, and environmental conditions. Tests were performed to evaluate a new, validated sponge wipe method using Bacillus atrophaeus spores. Testing evaluated the effects of spore concentration and surface material on recovery efficiency (RE), false-negative rate (FNR), limit of detection (LOD), and their uncertainties. Ceramic tile and stainless steel had the highest mean RE values (48.9 and 48.1%, respectively). Faux leather, vinyl tile, and painted wood had mean RE values of 30.3, 25.6, and 25.5, respectively, while plastic had the lowest mean RE (9.8%). Results show roughly linear dependences of RE and FNR on surface roughness, with smoother surfaces resulting in higher mean REs and lower FNRs. REs were not influenced by the low spore concentrations tested (3.10 × 10−3 to 1.86 CFU/cm2). Stainless steel had the lowest mean FNR (0.123), and plastic had the highest mean FNR (0.479). The LOD90 (≥1 CFU detected 90% of the time) varied with surface material, from 0.015 CFU/cm2 on stainless steel up to 0.039 on plastic. It may be possible to improve sampling results by considering surface roughness in selecting sampling locations and interpreting spore recovery data. Further, FNR values (calculated as a function of concentration and surface material) can be used presampling to calculate the numbers of samples for statistical sampling plans with desired performance and postsampling to calculate the confidence in characterization and clearance decisions. PMID:22138998
Qiu, Tian Yu; Yeo, Sharon; Tong, Louis
2018-01-01
Demodex infestations cause blepharitis and are difficult to treat. Recently, a new type of eyelid wipes with terpenoids has been found effective. We aim to evaluate patient satisfaction after short-term use and compare two teaching modalities on the techniques of use. Eligible participants were taught to use eyelid wipes (Cliradex ® ) by either live or online video demonstration based on random allocation. Participants used the wipes twice daily for a week. All participants had prior evaluation of socioeconomic status, dry eye symptoms, and meibomian gland features. After 1 week, competence of use was assessed by participants showing their technique to the investigator, and a questionnaire on comfort, ease, and convenience of use was administered. Higher scores indicate greater satisfaction, and these levels are compared among the two teaching modalities using chi square. A total of 50 participants were recruited, with a mean age of 42±16 years, and 88% of the participants were females. Overall, median comfort level was 4.0 (range: 1-6), ease level was 5.0 (3-6), and convenience level was 5.0 (2-6). Median stinging was 2.0 (1-4), which corresponded to some but mild stinging. The median competence level was 4.0 (2-4), which corresponded to excellent competence. These satisfactory levels (ease, comfort, and convenience) experienced were not significantly associated with different socioeconomic indicators, that is, housing type, income, highest education level, and were not different between teaching methods ( p >0.05). Short-term use of Cliradex eyelid wipes seems to be acceptable to most people. The teaching instructions before using these wipes were equally effective - whether live or online video demonstration was used.
Qiu, Tian Yu; Yeo, Sharon; Tong, Louis
2018-01-01
Purpose Demodex infestations cause blepharitis and are difficult to treat. Recently, a new type of eyelid wipes with terpenoids has been found effective. We aim to evaluate patient satisfaction after short-term use and compare two teaching modalities on the techniques of use. Patients and methods Eligible participants were taught to use eyelid wipes (Cliradex®) by either live or online video demonstration based on random allocation. Participants used the wipes twice daily for a week. All participants had prior evaluation of socioeconomic status, dry eye symptoms, and meibomian gland features. After 1 week, competence of use was assessed by participants showing their technique to the investigator, and a questionnaire on comfort, ease, and convenience of use was administered. Higher scores indicate greater satisfaction, and these levels are compared among the two teaching modalities using chi square. Results A total of 50 participants were recruited, with a mean age of 42±16 years, and 88% of the participants were females. Overall, median comfort level was 4.0 (range: 1–6), ease level was 5.0 (3–6), and convenience level was 5.0 (2–6). Median stinging was 2.0 (1–4), which corresponded to some but mild stinging. The median competence level was 4.0 (2–4), which corresponded to excellent competence. These satisfactory levels (ease, comfort, and convenience) experienced were not significantly associated with different socioeconomic indicators, that is, housing type, income, highest education level, and were not different between teaching methods (p>0.05). Conclusion Short-term use of Cliradex eyelid wipes seems to be acceptable to most people. The teaching instructions before using these wipes were equally effective – whether live or online video demonstration was used. PMID:29379270
Wong, Swee Siang; Huang, Cheng Hua; Yang, Chiu Chu; Hsieh, Yi Pei; Kuo, Chen Ni; Chen, Yi Ru; Chen, Li Ching
2018-01-01
Environmental cleaning is a fundamental principle of infection control in health care settings. We determined whether implementing separated environmental cleaning management measures in MICU reduced the density of HAI. We performed a 4-month prospective cohort intervention study between August and December 2013, at the MICU of Cathay General hospital. We arranged a training program for all the cleaning staff regarding separated environmental cleaning management measures by using disposable wipes of four colors to clean the patients' bedside areas, areas at a high risk of contamination, paperwork areas, and public areas. Fifteen high-touch surfaces were selected for cleanliness evaluation by using the adenosine triphosphate (ATP) bioluminescence test. Then data regarding HAI densities in the MICU were collected during the baseline, intervention, and late periods. A total of 120 ATP readings were obtained. The total number of clean high-touch surfaces increased from 13% to 53%, whereas that of unclean high-touch surface decreased from 47% to 20%. The densities of HAI were 14.32‰ and 14.90‰ during the baseline and intervention periods, respectively. The HAI density did not decrease after the intervention period, but it decreased to 9.07‰ during the late period. Implementing separated environmental cleaning management measures by using disposable wipes of four colors effectively improves cleanliness in MICU environments. However, no decrease in HAI density was observed within the study period. Considering that achieving high levels of hand-hygiene adherence is difficult, improving environmental cleaning is a crucial adjunctive measure for reducing the incidence of HAIs.
Feasibility: An important but neglected issue in patient hand hygiene.
Knighton, Shanina C; McDowell, Cherese; Rai, Herleen; Higgins, Patricia; Burant, Christopher; Donskey, Curtis J
2017-06-01
Patient hand hygiene may be a useful strategy to prevent acquisition of pathogens and to reduce the risk for transmission by colonized patients. Several studies demonstrate that patients and long-term-care facility (LTCF) residents may have difficulty using hand hygiene products that are provided; however, none of them measure feasibility for patients to use different hand hygiene products. A convenience sample of 42 hospitalized patients and 46 LTCF residents was assessed for their ability to use 3 hand sanitizer products (8-oz pushdown pump bottle, 2-oz pocket-sized bottle with a reclosable lid, and alcohol-impregnated hand wipes). The time (seconds) required for accessing each product was compared among acute-care patients and LTCF residents. Participants provided feedback on which product they preferred and found easiest to use. Of 88 participants, 86 (97.7%) preferred the pushdown pump, 2 (2.3%) preferred the bottle with the reclosable lid, and none preferred the hand wipes. For both hospitalized patients and LTCF residents, the average time required to access the pushdown pump was significantly less than the time required to access the other products (pushdown pump, 0.45 seconds; bottle with reclosable lid, 3.86 seconds; and wipes, 5.66 seconds; P < .001). Feasibility and ease of use should be considered in the selection of hand hygiene products for patients and LTCF residents. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
ODC-Free Solvent Implementation for Phenolics Cleaning
NASA Technical Reports Server (NTRS)
Wurth, Laura; Biegert, Lydia; Lamont, DT; McCool, Alex (Technical Monitor)
2001-01-01
During phenolic liner manufacture, resin-impregnated (pre-preg) bias tape of silica, glass, or carbon cloth is tape-wrapped, cured, machined, and then wiped with 1,1,1 tri-chloroethane (TCA) to remove contaminants that may have been introduced during machining and handling. Following the TCA wipe, the machined surface is given a resin wet-coat and over-wrapped with more prepreg and cured. A TCA replacement solvent for these wiping operations must effectively remove both surface contaminants, and sub-surface oils and greases while not compromising the integrity of this interface. Selection of a TCA replacement solvent for phenolic over-wrap interface cleaning began with sub-scale compatibility tests with cured phenolics. Additional compatibility tests included assessment of solvent retention in machined phenolic surfaces. Results from these tests showed that, while the candidate solvent did not degrade the cured phenolics, it was retained in higher concentrations than TCA in phenolic surfaces. This effect was most pronounced with glass and silica cloth phenolics with steep ply angles relative to the wiped surfaces.
Kurashige, E Jessica Ohashi; Oie, Shigeharu; Furukawa, H
2016-01-01
Methicillin-resistant Staphylococcus aureus (MRSA) can contaminate environmental surfaces that are frequently touched by the hands of patients with MRSA colonization/infection. There have been many studies in which the presence or absence of MRSA contamination was determined but no studies in which MRSA contamination levels were also evaluated in detail. We evaluated MRSA contamination of environmental surfaces (overbed tables, bed side rails, and curtains) in the rooms of inpatients from whom MRSA was isolated via clinical specimens. We examined the curtains within 7-14 days after they had been newly hung. The environmental surfaces were wiped using gauze (molded gauze for wiping of surface bacteria; 100% cotton, 4cm×8cm) moistened with sterile physiological saline. The MRSA contamination rate and mean counts (range) were 25.0% (6/24 samples) and 30.6 (0-255)colony-forming units (cfu)/100cm(2), respectively, for the overbed tables and 31.6% (6/19 samples) and 159.5 (0-1620)cfu/100cm(2), respectively, for the bed side rails. No MRSA was detected in 24 curtain samples. The rate of MRSA contamination of environmental surfaces was high for the overbed tables and bed side rails but low for the curtains. Therefore, at least until the 14th day of use, frequent disinfection of curtains may be not necessary. Copyright © 2016. Published by Elsevier Editora Ltda.
Due to the potential for ingestion of chromated copper arsenate (CCA) by the hand-to-mouth activities of young children who contact CCA treated wood, EPA has used wipe samples to study the potential benefits of paint-like coatings on CCA treated wood. Citizens who may be concern...
Pleil, Joachim D; Lorber, Matthew N
2007-11-01
The United States Environmental Protection Agency collected ambient air samples in lower Manhattan for about 9 months following the September 11, 2001 World Trade Center (WTC) attacks. Measurements were made of a host of airborne contaminants including volatile organic compounds, polycyclic aromatic hydrocarbons, asbestos, lead, and other contaminants of concern. The present study focuses on the broad class of polychlorinated dibenzo-p-dioxins (CDDs) and dibenzofurans (CDFs) with specific emphasis on the 17 CDD/CDF congeners that exhibit mammalian toxicity. This work is a statistical study comparing the internal patterns of CDD/CDFs using data from an unambiguous fire event (WTC) and other data sets to help identify their sources. A subset of 29 samples all taken between September 16 and October 31, 2001 were treated as a basis set known to be heavily impacted by the WTC building fire source. A second basis set was created using data from Los Angeles and Oakland, CA as published by the California Air Resources Board (CARB) and treated as the archetypical background pattern for CDD/CDFs. The CARB data had a congener profile appearing similar to background air samples from different locations in America and around the world and in different matrices, such as background soils. Such disparate data would normally be interpreted with a qualitative pattern recognition based on congener bar graphs or other forms of factor or cluster analysis that group similar samples together graphically. The procedure developed here employs aspects of those statistical methods to develop a single continuous output variable per sample. Specifically, a form of variance structure-based cluster analysis is used to group congeners within samples to reduce collinearity in the basis sets, new variables are created based on these groups, and multivariate regression is applied to the reduced variable set to determine a predictive equation. This equation predicts a value for an output variable, OPT: the predicted value of OPT is near zero (0.00) for a background congener profile and near one (1.00) forthe profile characterized by the WTC air profile. Although this empirical method is calibrated with relatively small sets of airborne samples, it is shown to be generalizable to other WTC, fire source, and background air samples as well as other sample matrices including soils, window films and other dust wipes, and bulk dusts. However, given the limited data set examined, the method does not allow further discrimination between the WTC data and the other fire sources. This type of analysis is demonstrated to be useful for complex trace-level data sets with limited data and some below-detection entries.
Astronaut Nelson wipes off helmet visor in the middeck of Shuttle Challenger
NASA Technical Reports Server (NTRS)
1984-01-01
Astronaut George D. Nelson, 41-C mission specialist, wipes off his helmet visor in the middeck of Shuttle Challenger. Astronaut James D. van. Hoften, is seen in the background. Both crew members are wearing the liquid cooled undergarments for the extravehicular mobility unit (EMU).
Scherer, Emeline; Rocchi, Steffi; Reboux, Gabriel; Vandentorren, Stéphanie; Roussel, Sandrine; Vacheyrou, Mallory; Raherison, Chantal; Millon, Laurence
2014-01-01
The aim of the present study was to assess performance, feasibility and relevance of a Standard Operational Procedure (SOP) for large-scale use in the microbial analysis of children's indoor environments. We analyzed dust settled on Electrostatic Dust Fall Collectors (EDCs) by using qPCR which targeted 6 molds, 3 bacteria and 1 mite, chosen for their involvement in allergic or inflammatory processes. Six types of commercialized electrostatic wipes were tested for their releasing capacity of fungal DNA from fungal spores captured by the wipes. Specificity, repeatability and detection limits of the qPCR procedure were tested using calibrated microbial suspensions. The feasibility and relevance of this sampling and analysis method were assessed in a 75-home pilot study. Our result showed that one specific make of wipe was more effective than the others in releasing fungal DNA. qPCR procedure showed good repeatability. The quantification limit was about 5 fg DNA/μL for all species except Penicillium chrysogenum (0.5 fg DNA/μL) and Dermatophagoïdes pteronyssinus (10 fg DNA/μL). No cross-reactivity was observed. DNA concentrations in the 53/75 homes participating in the pilot study were between 0 and 24 625, 0 and 69 738 equivalent cells per cm(2) for the fungi and bacteria, and between 0 and 1 equivalent mites per cm(2) for D. pteronyssinus. Using the SOP described, we were able to classify the 53 dwellings from the least to the most contaminated according to the quantity of DNA measured for each species. Our SOP measured fungi, bacteria and mites using a cost-efficient, discreet and well-accepted sampling method with just one qPCR tool. The whole procedure can be used for microbial analysis in large cohort studies such as the ELFE study ("Etude Longitudinale Française depuis l'Enfance") and could help improve our understanding of the interactions between the environment, allergic diseases and child development. © 2013.
1988-06-01
Valve Pit Number 2 Location One near hydrazine/aerozine tank area .nd one near wastewater tank area *There is a variety of underground piping at the...loading station (wipe of drum filling nozzles/connectors) 3,475 19.u I W-1U Tank HAS-?, drain value (Tank pit valve ) <S ɘ.2 W-110 Tank HAS-I, control... valve (on top) sample bottle broken W-111 Tank Truck Station, Truck loading filler nozzle and boom sample bottle broken I/ UUMH - 1,1
Microbiological Sampling Methods and Sanitation of Edible Plants Grown on ISS
NASA Technical Reports Server (NTRS)
Parrish, Charles H. II; Khodadad, Christina L.; Garland, Nathaniel T.; Larson, Brian D.; Hummreick, Mary E.
2013-01-01
Pathogenic microbes on the surfaces of salad crops and growth chambers pose a threat to the health of crew on International Space Station. For astronauts to safely consume spacegrown vegetables produced in NASA's new vegetable production unit, VEGGIE, three technical challenges must be overcome: real-time sampling, microbiological analysis, and sanitation. Raphanus sativus cultivar Cherry Bomb II and Latuca sativa cultivar Outredgeous, two saled crops to be grown in VEGGIE, were inoculated with Salmonella enterica serovar Typhimurium (S. Typhimurium), a bacterium known to cause food-borne illness Tape- and swab-based sampling techniques were optimized for use in microgravity and assessed for effectiveness in recovery of bacteria from crop surfaces: Rapid pathogen detection and molecular analyses were performed via quantitative real-time polymerase chain reactiop using LightCycler® 480 and RAZOR® EX, a scaled-down instrument that is undergoing evaluation and testing for future flight hardware. These methods were compared with conventional, culture-based methods for the recovery of S. Typhimurium colonies. A sterile wipe saturated with a citric acid-based, food-grade sanitizer was applied to two different surface materials used in VEGGIE flight hardware that had been contaminated with the bacterium Pseudomonas aeruginosa,. another known human pathogen. To sanitize surfaces, wipes were saturated with either the sanitizer or sterile deionized water and applied to each surface. Colony forming units of P. aeruginosa grown on tryptic soy agar plates were enumerated from surface samples after sanitization treatments. Depending on the VEGGIE hardware material, 2- to 4.5-log10 reductions in colony-forming units were observed after sanitization. The difference in recovery of S. Typhimurium between tape- and swab- based sampling techniques was insignificant. RAZOR® EX rapidly detected S. Typhimurium present in both raw culture and extracted DNA samples.
Schecter, Arnold; Päpke, Olaf; Joseph, Jean Elizabeth; Tung, Kuang-Chi
2005-04-09
Polybrominated diphenyl ethers (PBDEs), a type of brominated flame retardant chemically and toxicologically similar to polychlorinated biphenyls (PCBs), are a class of emerging environmental and human contaminants. They have recently been detected in U.S. milk, blood, and food at the highest levels in the world. This pilot study was undertaken with the aim of determining levels of PBDE in the U.S. indoor environment, to assess the potential exposure to PBDEs from computer surfaces and carpets. Food of animal origin is the usual source of polychlorinated dibenzo-p-dioxin (PCDD), polychlorinated dibenzofurans (PCDF), and PCBs in humans, but there may also be environmental sources for intake of PBDEs. It was also our aim to characterize the PBDE congener profile in these indoor environmental samples. Four computer wipe samples and 9 domestic vacuum-sweeping samples were analyzed for 13 PBDE congeners, PBDEs 17 (2,2',4), 28 (2,4,4'?), 47 (2,2',4,4'?), 66 (2,3',4,4'?), 77 (3,3',4,4'?), 85 (2,2',3,4,4'?), 99 (2,2'4,4',5), 100 (2,2',4,4',6), 138 (2,2',3,4,4',5'?), 153 (2,2',4,4',5,5'?), 154 (2,2',4,4',5,6'?), 183 (2,2',3,4,4',5',6), and 209 (2,2',3,3',4,4',5,5',6,6'?). All samples tested positive for PBDEs. PBDE 209 was the dominant congener in all 4 computer wipe samples and in 7 out of the 9 vacuum dust samples. The congener profiles observed in this study varied considerably, a finding that has been observed previously. However these congener profiles differ from the pattern seen in U.S. human milk, human blood and in food, where PBDEs 47 and 99 predominate.
Gura, Sigalit; Guerra-Diaz, Patricia; Lai, Hanh; Almirall, José R
2009-07-01
Trace detection of illicit drugs challenges the scientific community to develop improved sensitivity and selectivity in sampling and detection techniques. Ion mobility spectrometry (IMS) is one of the prominent trace detectors for illicit drugs and explosives, mostly due to its portability, high sensitivity and fast analysis. Current sampling methods for IMS rely on wiping suspected surfaces or withdrawing air through filters to collect particulates. These methods depend greatly on the particulates being bound onto surfaces or having sufficient vapour pressure to be airborne. Many of these compounds are not readily available in the headspace due to their low vapour pressure. This research presents a novel SPME device for enhanced air sampling and shows the use of optimized IMS by genetic algorithms to target volatile markers and/or odour signatures of illicit substances. The sampling method was based on unique static samplers, planar substrates coated with sol-gel polydimethyl siloxane (PDMS) nanoparticles, also known as planar solid-phase microextraction (PSPME). Due to its surface chemistry, high surface area and capacity, PSPME provides significant increases in sensitivity over conventional fibre SPME. The results show a 50-400 times increase in the detection capacity for piperonal, the odour signature of 3,4-methylenedioxymethamphetamine (MDMA). The PSPME-IMS technique was able to detect 600 ng of piperonal in a 30 s extraction from a quart-sized can containing 5 MDMA tablets, while detection using fibre SPME-IMS was not attainable. In a blind study of six cases suspected to contain varying amounts of MDMA in the tablets, PSPME-IMS successfully detected five positive cases and also produced no false positives or false negatives. One positive case had minimal amounts of MDMA resulting in a false negative response for fibre SPME-IMS.
Mechanisms of Photo Degradation for Layered Silicate-Polycarbonate Nanocomposites
2005-09-01
crystal was used as the sampling accessory. The UV/VIS spectra were recorded using a Cary 5G UV/VIS/ near - infrared (NIR) spectrometer set to scan in...transform infrared spectroscopy. The results reveal that the carbonate linkages undergo a scission reaction upon UV exposure, thereby compromising the...were wiped clean before spectroscopic analysis. 3.3 Spectroscopic Measurements Infrared measurements were recorded on a Nicolet model 560 Magna
Environmental lead exposure risks associated with children's outdoor playgrounds.
Taylor, Mark Patrick; Camenzuli, Danielle; Kristensen, Louise Jane; Forbes, Miriam; Zahran, Sammy
2013-07-01
This study examines exposure risks associated with lead smelter emissions at children's public playgrounds in Port Pirie, South Australia. Lead and other metal values were measured in air, soil, surface dust and on pre- and post-play hand wipes. Playgrounds closest to the smelter were significantly more lead contaminated compared to those further away (t(27.545) = 3.76; p = .001). Port Pirie post-play hand wipes contained significantly higher lead loadings (maximum hand lead value of 49,432 μg/m(2)) than pre-play hand wipes (t(27) = 3.57, p = .001). A 1% increase in air lead (μg/m(3)) was related to a 0.713% increase in lead dust on play surfaces (95% CI, 0.253-1.174), and a 0.612% increase in post-play wipe lead (95% CI, 0.257-0.970). Contaminated dust from smelter emissions is determined as the source and cause of childhood lead poisoning at a rate of approximately one child every third day. Copyright © 2013 Elsevier Ltd. All rights reserved.
Beyond douching: use of feminine hygiene products and STI risk among young women.
Ott, Mary A; Ofner, Susan; Fortenberry, J Dennis
2009-05-01
Use of feminine hygiene products (feminine wipes, sprays, douches, and yeast creams) by adolescent women is common, yet understudied. We examine the association among these genital hygiene behaviors, condom use, and sexually transmitted infection (STI). Using the interview as our unit of analysis, we examined associations between genital hygiene behaviors (use of feminine wipes, feminine sprays, douches, or yeast creams), STI risk factors, and infection with Chlamydia trachomatis, Neisseria gonorrhoeae, and Trichomonas vaginalis. We recruited 295 adolescent women from primary care clinics as part of a larger longitudinal study of STI among high-risk adolescents. Participants completed face-to-face interviews every 3 months, and provided vaginal swabs for STI testing. Data were analyzed with repeated measures logistic models to control for multiple observations contributed by each participant. Participants reported douching in 25% of interviews, feminine sprays in 29%, feminine wipes in 27%, and yeast creams in 19% of interviews. We observed a co-occurrence of douching, spraying, and wiping. A past STI (6 months or more prior) was associated with increased likelihood of yeast cream use, and a recent STI (3 months prior) was associated with increased likelihood of feminine wipe use. Condom use was modestly associated with increased likelihood of douching. Young women frequently use feminine hygiene products, and it is important for clinicians to inquire about use as these products may mimic or mask STI. We found no associations between douching and STI, but instead modest associations between hygiene and STI prevention, suggesting motivation for self-care.
Security of patient data when decommissioning ultrasound systems.
Moggridge, James
2017-02-01
Although ultrasound systems generally archive to Picture Archiving and Communication Systems (PACS), their archiving workflow typically involves storage to an internal hard disk before data are transferred onwards. Deleting records from the local system will delete entries in the database and from the file allocation table or equivalent but, as with a PC, files can be recovered. Great care is taken with disposal of media from a healthcare organisation to prevent data breaches, but ultrasound systems are routinely returned to lease companies, sold on or donated to third parties without such controls. In this project, five methods of hard disk erasure were tested on nine ultrasound systems being decommissioned: the system's own delete function; full reinstallation of system software; the manufacturer's own disk wiping service; open source disk wiping software for full and just blank space erasure. Attempts were then made to recover data using open source recovery tools. All methods deleted patient data as viewable from the ultrasound system and from browsing the disk from a PC. However, patient identifiable data (PID) could be recovered following the system's own deletion and the reinstallation methods. No PID could be recovered after using the manufacturer's wiping service or the open source wiping software. The typical method of reinstalling an ultrasound system's software may not prevent PID from being recovered. When transferring ownership, care should be taken that an ultrasound system's hard disk has been wiped to a sufficient level, particularly if the scanner is to be returned with approved parts and in a fully working state.
McKernan, Lauralynn Taylor; Burge, Harriet; Wallingford, Kenneth M; Hein, Misty J; Herrick, Robert
2007-04-01
Given the potential health effects of fungi and the amount of time aircrew and passengers spend inside aircraft, it is important to study fungal populations in the aircraft environment. Research objectives included documenting the genera/species of airborne culturable fungal concentrations and total spore concentrations on a twin-aisle wide body commercial passenger aircraft. Twelve flights between 4.5 and 6.5 h in duration on Boeing 767 (B-767) aircraft were evaluated. Two air cooling packs and 50% recirculation rate (i.e. 50:50 mix of outside air and filtered inside air) were utilized during flight operations. Passenger occupancy rates varied from 67 to 100%. N-6 impactors and total spore traps were used to collect sequential, triplicate air samples in the front and rear of coach class during six sampling intervals throughout each flight: boarding, mid-climb, early cruise, mid-cruise, late cruise and deplaning. Comparison air samples were also collected inside and outside the airport terminals at the origin and destination cities resulting in a total of 522 culturable and 517 total spore samples. A total of 45 surface wipe samples were collected using swabs onboard the aircraft and inside the airport terminals. A variety of taxa were observed in the culturable and total spore samples. A frequency analysis of the fungal data indicated that Cladosporium, Aspergillus and Penicillium were predominant genera in the culturable samples whereas Cladosporium, Basidiospores and Penicillium/Aspergillus were predominant in the total spore samples. Fungal populations observed inside the aircraft were comprised of similar genera, detected significantly less frequently and with lower mean concentrations than those observed in typical office buildings. Although sources internal to the aircraft could not be ruled out, our data demonstrate the importance of passenger activity as the source of the fungi observed on aircraft. Isolated fungal peak events occurred occasionally when concentrations of a particular genus or species rose sharply inside the cabin for a limited period. Overall, our research demonstrates that on the sampled flights the B-767 filtration system operated efficiently to remove fungal spores when two air cooling packs and 50% recirculation rate were utilized during flight operations.
Yu, Chang Ho; Fan, Zhihua Tina; McCandlish, Elizabeth; Stern, Alan H; Lioy, Paul J
2011-10-01
The objective of this study was to estimate the contribution of a facility that processes steel production slag into raw material for cement production to local outdoor particle deposition in Camden, NJ. A dry deposition sampler that can house four 37-mm quartz fiber filters was developed and used for the collection of atmospheric particle deposits. Two rounds of particle collection (3-4 weeks each) were conducted in 8-11 locations 200-800 m downwind of the facility. Background samples were concurrently collected in a remote area located ∼2 km upwind from the facility. In addition, duplicate surface wipe samples were collected side-by-side from each of the 13 locations within the same sampling area during the first deposition sampling period. One composite source material sample was also collected from a pile stored in the facility. Both the bulk of the source material and the <38 μm fraction subsample were analyzed to obtain the elemental source profile. The particle deposition flux in the study area was higher (24-83 mg/m 2 ·day) than at the background sites (13-17 mg/m 2 ·day). The concentration of Ca, a major element in the cement source production material, was found to exponentially decrease with increasing downwind distance from the facility (P < 0.05). The ratio of Ca/Al, an indicator of Ca enrichment due to anthropogenic sources in a given sample, showed a similar trend. These observations suggest a significant contribution of the facility to the local particle deposition. The contribution of the facility to outdoor deposited particle mass was further estimated by three independent models using the measurements obtained from this study. The estimated contributions to particle deposition in the study area were 1.8-7.4% from the regression analysis of the Ca concentration in particle deposition samples against the distance from the facility, 0-11% from the U.S. Environmental Protection Agency (EPA) Chemical Mass Balance (CMB) source-receptor model, and 7.6-13% from the EPA Industrial Source Complex Short Term (ISCST3) dispersion model using the particle-size-adjusted permit-based emissions estimates. [Box: see text].
Code of Federal Regulations, 2013 CFR
2013-01-01
.... The entire radioactive surface of the source shall be wiped with filter paper, moistened with water... shall be wiped with filter paper with the application of moderate finger pressure. Removal of radioactive material from the source shall be determined by measuring the radioactivity on the filter paper or...
Code of Federal Regulations, 2012 CFR
2012-01-01
... entire radioactive surface of the source shall be wiped with filter paper, moistened with water, with the... wiped with filter paper with the application of moderate finger pressure. Removal of radioactive material from the source shall be determined by measuring the radioactivity on the filter paper or by...
Code of Federal Regulations, 2014 CFR
2014-01-01
.... The entire radioactive surface of the source shall be wiped with filter paper, moistened with water... shall be wiped with filter paper with the application of moderate finger pressure. Removal of radioactive material from the source shall be determined by measuring the radioactivity on the filter paper or...
Code of Federal Regulations, 2012 CFR
2012-01-01
.... The entire radioactive surface of the source shall be wiped with filter paper, moistened with water... shall be wiped with filter paper with the application of moderate finger pressure. Removal of radioactive material from the source shall be determined by measuring the radioactivity on the filter paper or...
USDA-ARS?s Scientific Manuscript database
Quaternary ammonium compounds, commonly referred to as quats, are cationic surfactants widely used as the active biocide ingredient for disposable disinfecting wipes. The cationic nature of quats results in a strong ionic interaction and adsorption onto wipes materials that have an anionic surface ...
Limitations of the efficacy of surface disinfection in the healthcare setting.
Williams, Gareth J; Denyer, Stephen P; Hosein, Ian K; Hill, Dylan W; Maillard, Jean-Yves
2009-06-01
We examined the efficacy of 2 commercially available wipes to effectively remove, kill, and prevent the transfer of both methicillin-resistant and methicillin-susceptible Staphylococcus aureus from contaminated surfaces. Although wipes play a role in decreasing the number of pathogenic bacteria from contaminated surfaces, they can potentially transfer bacteria to other surfaces if they are reused.
NASA Astrophysics Data System (ADS)
Viacheslav, Ilyin; Korshunov, Denis
Recovery of various organic wastes in space flight is an actual problem of modern astronautics and future interplanetary missions. Currently, organic waste are incinerated in the dense layers of the Earth's atmosphere in cargo containers. However, this method of anthropogenic waste treatment is not environmentally compatible with future interplanetary missions, and is not suitable due to planetary quarantine requirements. Furthermore, the maintaining of a closed ecosystem in spaceship is considered as one of the main ways of ensuring the food and air crew in the long term fully autonomous space expedition. Such isolated ecosystem is not conceivable without biotransformation of organic waste. In this regard, currently new ways of recycling organic waste are currently developed. The most promising method is a method for processing organic waste using thermophilic anaerobic microbial communities.However, the products of anaerobic fermentation of solid organic materials contain significant amounts of organic impurities, which often give them sour pH. This presents a significant problem because it does not allow to use this fluid as process water without pretreatment. Fermentation products - alcohols, volatile fatty acids other carbonaceous substances must be withdrawn.One way to solve this problem may be the use of microorganisms biodestructors for recycling organic impurities in the products of anaerobic biodegradation Under the proposed approach, the metabolic products (having acidic pH) of primary biotransformation of solid organic materials are used as media for the cultivation of fungi. Thus, cellulosic wastes are recycled in two successive stages. The aim of this work was to test the effectiveness of post-treatment liquid products of biodegradation of hygienic cotton wipes (common type of waste on the ISS) by the fungus Trichoderma viridae under orbital flight. The study was conducted onboard biosatellite Bion -M1, where was placed a bioreactor, designed to carry out the fermentation in space flight. For aerobic post-treatment of substrates remaining after biodegradation of cotton wipe there was selected a strain of the fungus Trihoderma viridae, able to grow at a slightly acid environment , and to bring the pH to neutral values. Bioreactor working volume of 40 ml, where 20 ml of liquid subjected to post-treatment was placed. Strain Trihoderma viridae, isolated from ISS environment, showed steady growth in terms identical to those of pre- cultivation. Efficiency of purification was assessed using the method of gas chromatography-mass spectrometry comparing the amount and concentration of the volatile organic compounds in the samples. It turned out that the number of compounds detected in the flight sample almost halved compared to the original sample obtained after biodegradation gauze anaerobic bacteria. The total concentration of volatile impurities dropped 6 times. Thus, despite the limited resource of oxygen, due to lack of aeration in the bioreactor strain Trihoderma viridae demonstrated the ability to perform aerobic purification of substrate obtained after anaerobic biodegradation of cotton wipes under orbital flight.
Exposure to flame retardant chemicals on commercial airplanes
2013-01-01
Background Flame retardant chemicals are used in materials on airplanes to slow the propagation of fire. These chemicals migrate from their source products and can be found in the dust of airplanes, creating the potential for exposure. Methods To characterize exposure to flame retardant chemicals in airplane dust, we collected dust samples from locations inside 19 commercial airplanes parked overnight at airport gates. In addition, hand-wipe samples were also collected from 9 flight attendants and 1 passenger who had just taken a cross-country (USA) flight. The samples were analyzed for a suite of flame retardant chemicals. To identify the possible sources for the brominated flame retardants, we used a portable XRF analyzer to quantify bromine concentrations in materials inside the airplanes. Results A wide range of flame retardant compounds were detected in 100% of the dust samples collected from airplanes, including BDEs 47, 99, 153, 183 and 209, tris(1,3-dichloro-isopropyl)phosphate (TDCPP), hexabromocyclododecane (HBCD) and bis-(2-ethylhexyl)-tetrabromo-phthalate (TBPH). Airplane dust contained elevated concentrations of BDE 209 (GM: 500 ug/g; range: 2,600 ug/g) relative to other indoor environments, such as residential and commercial buildings, and the hands of participants after a cross-country flight contained elevated BDE 209 concentrations relative to the general population. TDCPP, a known carcinogen that was removed from use in children’s pajamas in the 1970’s although still used today in other consumer products, was detected on 100% of airplanes in concentrations similar to those found in residential and commercial locations. Conclusion This study adds to the limited body of knowledge regarding exposure to flame retardants on commercial aircraft, an environment long hypothesized to be at risk for maximum exposures due to strict flame retardant standards for aircraft materials. Our findings indicate that flame retardants are widely used in many airplane components and all airplane types, as expected. Most flame retardants, including TDCPP, were detected in 100% of dust samples collected from the airplanes. The concentrations of BDE 209 were elevated by orders of magnitude relative to residential and office environments. PMID:23413926
Exposure to flame retardant chemicals on commercial airplanes.
Allen, Joseph G; Stapleton, Heather M; Vallarino, Jose; McNeely, Eileen; McClean, Michael D; Harrad, Stuart J; Rauert, Cassandra B; Spengler, John D
2013-02-16
Flame retardant chemicals are used in materials on airplanes to slow the propagation of fire. These chemicals migrate from their source products and can be found in the dust of airplanes, creating the potential for exposure. To characterize exposure to flame retardant chemicals in airplane dust, we collected dust samples from locations inside 19 commercial airplanes parked overnight at airport gates. In addition, hand-wipe samples were also collected from 9 flight attendants and 1 passenger who had just taken a cross-country (USA) flight. The samples were analyzed for a suite of flame retardant chemicals. To identify the possible sources for the brominated flame retardants, we used a portable XRF analyzer to quantify bromine concentrations in materials inside the airplanes. A wide range of flame retardant compounds were detected in 100% of the dust samples collected from airplanes, including BDEs 47, 99, 153, 183 and 209, tris(1,3-dichloro-isopropyl)phosphate (TDCPP), hexabromocyclododecane (HBCD) and bis-(2-ethylhexyl)-tetrabromo-phthalate (TBPH). Airplane dust contained elevated concentrations of BDE 209 (GM: 500 ug/g; range: 2,600 ug/g) relative to other indoor environments, such as residential and commercial buildings, and the hands of participants after a cross-country flight contained elevated BDE 209 concentrations relative to the general population. TDCPP, a known carcinogen that was removed from use in children's pajamas in the 1970's although still used today in other consumer products, was detected on 100% of airplanes in concentrations similar to those found in residential and commercial locations. This study adds to the limited body of knowledge regarding exposure to flame retardants on commercial aircraft, an environment long hypothesized to be at risk for maximum exposures due to strict flame retardant standards for aircraft materials. Our findings indicate that flame retardants are widely used in many airplane components and all airplane types, as expected. Most flame retardants, including TDCPP, were detected in 100% of dust samples collected from the airplanes. The concentrations of BDE 209 were elevated by orders of magnitude relative to residential and office environments.
Beyond Douching: Use of Feminine Hygiene Products and STI Risk Among Young Women
Ott, Mary A.; Ofner, Susan; Fortenberry, J. Dennis
2010-01-01
Introduction Use of feminine hygiene products (feminine wipes, sprays, douches, and yeast creams) is common, yet understudied. Aim We examine the association among these genital hygiene behaviors, condom use, and STI. Methods We recruited 295 adolescent young women from primary care clinics as part of a larger longitudinal study of STI among high risk adolescents. Participants completed face-to-face interviews every three months, and provided vaginal swabs for STI testing. Main Outcome Measures Using the interview as our unit of analysis, we examined associations between genital hygiene behaviors (use of feminine wipes, feminine sprays, douches, or yeast creams), STI risk factors, and infection with C. trachomatis, N. gonorrhoeae, and T. vaginalis. Data were analyzed with repeated measures logistic models to control for multiple observations contributed by each participant. Results Participants reported douching in 25% of interviews, feminine sprays in 29%, feminine wipes in 27%, and yeast creams in19% of interviews. We observed a co-occurrence of douching, spraying and wiping. A past STI (6 months or more prior) was associated with increased likelihood of yeast cream use, and a recent STI (3 months prior) was associated with increased likelihood of feminine wipe use. Condom use was modestly associated with increased likelihood of douching. Conclusions Young women frequently use feminine hygiene products, and it is important for clinicians to inquire about use as these products may mimic or mask STI. We found no associations between douching and STI, but instead modest associations between hygiene and STI prevention, suggesting motivation for self-care. PMID:19170863
Disinfecting the iPad: evaluating effective methods.
Howell, V; Thoppil, A; Mariyaselvam, M; Jones, R; Young, H; Sharma, S; Blunt, M; Young, P
2014-06-01
Tablet computers are increasingly used in healthcare, but they may carry nosocomial pathogens. There are few data available on how to clean an iPad effectively for use in the clinical setting. We aimed to identify the most effective method of decontaminating the Apple iPad, without causing damage, and establish the duration of any residual effect. Following contamination with a microbial broth (meticillin-resistant Staphylococcus aureus (MRSA), vancomycin-resistant enterococcus (VRE) and Clostridium difficile), we examined efficacy of iPad disinfection in the laboratory using six different disinfectant wipes: Sani-Cloth CHG 2% (chlorhexidine 2%/alcohol 70%), Clorox, Tristel, Trigene, soap and water, and plain cloth. Following cleaning, iPads were recontaminated to examine residual activity. After 480 Sani-Cloth CHG 2% disinfecting episodes, functional and visual analysis of iPads was performed by blinded subjects. With the exception of Clostridium difficile, Sani-Cloth CHG 2% and Clorox wipes were most effective against MRSA and VRE, and they were significantly better than the Apple-recommended plain cloth (P ≤ 0.001). A substantial residual antimicrobial effect was seen for >6h after wiping the iPad with Sani-Cloth CHG 2% despite repeated recontamination and without further disinfection. The functionality or visual appearance of the iPad was not damaged by repeated use of Sani-Cloth CHG 2% wipes. Sani-Cloth CHG 2% wipes effectively disinfect the iPad against MRSA and VRE, with a residual antibacterial effect and without causing damage. Copyright © 2014 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.
Security of patient data when decommissioning ultrasound systems
2017-01-01
Background Although ultrasound systems generally archive to Picture Archiving and Communication Systems (PACS), their archiving workflow typically involves storage to an internal hard disk before data are transferred onwards. Deleting records from the local system will delete entries in the database and from the file allocation table or equivalent but, as with a PC, files can be recovered. Great care is taken with disposal of media from a healthcare organisation to prevent data breaches, but ultrasound systems are routinely returned to lease companies, sold on or donated to third parties without such controls. Methods In this project, five methods of hard disk erasure were tested on nine ultrasound systems being decommissioned: the system’s own delete function; full reinstallation of system software; the manufacturer’s own disk wiping service; open source disk wiping software for full and just blank space erasure. Attempts were then made to recover data using open source recovery tools. Results All methods deleted patient data as viewable from the ultrasound system and from browsing the disk from a PC. However, patient identifiable data (PID) could be recovered following the system’s own deletion and the reinstallation methods. No PID could be recovered after using the manufacturer’s wiping service or the open source wiping software. Conclusion The typical method of reinstalling an ultrasound system’s software may not prevent PID from being recovered. When transferring ownership, care should be taken that an ultrasound system’s hard disk has been wiped to a sufficient level, particularly if the scanner is to be returned with approved parts and in a fully working state. PMID:28228821
ERIC Educational Resources Information Center
Education Law Center, Inc., Newark, NJ.
In "Abbott v. Burke" the New Jersey Supreme Court determined that the state constitutional guarantee to a thorough and efficient education must include a supplemental program designed to wipe out the deficits poor children bring with them to school. In this report, the Education Law Center draws on educational research to identify the…
Forced Suffocation of Infants with Baby Wipes: A Previously Undescribed Form of Child Abuse
ERIC Educational Resources Information Center
Krugman, Scott D.; Lantz, Patrick E.; Sinal, Sara; De Jong, Allan R.; Coffman, Kathryn
2007-01-01
Background: Foreign body aspiration in children is commonly seen in emergency departments and carries a significant mortality. Abusive foreign body suffocation is not well described. Methods: We present a case-series of four infants who presented with aspiration of a baby wipe. Results: Each child was found to be a victim of child physical abuse…
Problem prevention and holistic pest management [Chapter 14
Thomas D. Landis; Tara Luna; R. Kasten Dumroese; Kim M. Wilkinson
2014-01-01
As any experienced grower knows only too well, nursery management is a continuous process of solving problems. One recurring problem is pests. In the past, nursery managers waited for an insect or disease to appear and then sprayed some toxic chemical to wipe out the pest or disease. This approach, however, also wipes out natural predators of the pest, resulting in an...
Body wiping behaviors associated with cutaneous lipids in hylid tree frogs of Florida.
Barbeau, Tamatha R; Lillywhite, Harvey B
2005-06-01
Body wiping behavior, integumentary secretions and rates of evaporative water loss (EWL) were examined in six species of Florida tree frogs (Anura: Hylidae). Additionally, morphology of the integument and dermal glands were compared among these and one other Florida tree frog (Hyla andersonii), an arid-adapted tree frog (Phyllomedusa hypochondrialis), and a highly aquatic frog (Rana utricularia). An extra-epidermal layer of lipid and mucus, presumably secreted from dermal granular glands, was detected on the skin of all Florida hylid frogs examined. Distinct body wiping behaviors were observed in the hylid frogs, but these were less complex than those described previously in phyllomedusine frogs, which occupy arid habitats, secrete lipids onto their skin, and are regarded as relatively 'waterproof'. Florida hylids occupy seasonally arid habitats and appear to have reduced rates of EWL. The suite of traits we observed in these frogs have been previously documented in a rhacophorid tree frog from seasonally arid regions of India and likely represent an evolutionary convergent response to periodic dehydration stress. The presence of lipids that are spread by simple wiping behaviors to form an extra-epidermal water barrier may represent an early stage of the more advanced adaptations described in more waterproof arboreal frogs.
Remote Wiping and Secure Deletion on Mobile Devices: A Review.
Leom, Ming Di; Choo, Kim-Kwang Raymond; Hunt, Ray
2016-11-01
Mobile devices have become ubiquitous in almost every sector of both private and commercial endeavors. As a result of such widespread use in everyday life, many users knowingly and unknowingly save significant amounts of personal and/or commercial data on these mobile devices. Thus, loss of mobile devices through accident or theft can expose users-and their businesses-to significant personal and corporate cost. To mitigate this data leakage issue, remote wiping features have been introduced to modern mobile devices. Given the destructive nature of such a feature, however, it may be subject to criminal exploitation (e.g., a criminal exploiting one or more vulnerabilities to issue a remote wiping command to the victim's device). To obtain a better understanding of remote wiping, we survey the literature, focusing on existing approaches to secure flash storage deletion and provide a critical analysis and comparison of a variety of published research in this area. In support of our analysis, we further provide prototype experimental results for three Android devices, thus providing both a theoretical and applied focus to this article as well as providing directions for further research. © 2016 American Academy of Forensic Sciences.
Methylisothiazolinone: an emergent allergen in common pediatric skin care products.
Schlichte, Megan J; Katta, Rajani
2014-01-01
Recalcitrant dermatitis, such as that of the hands, face, or genitals, may be due to allergic contact dermatitis (ACD) from ingredients in seemingly innocuous personal care products. Rising rates of allergy have been noted due to the preservative methylisothiazolinone (MI). This preservative is commonly found in skin and hair care products, especially wipes. This study evaluated the use of MI in products specifically marketed for babies and children and examined the associated marketing terms of such products. Ingredients of skin care products specifically marketed for babies and children were surveyed at two major retailers. Of 152 products surveyed, 30 products contained MI. Categories of products surveyed included facial or body wipes, antibacterial hand wipes, hair products, soaps, bubble baths, moisturizers, and sunscreens. Facial or body wipes and hair products were the categories with the greatest number of MI-containing products. MI-containing products were manufactured by a number of popular brands. Of note, products marketed as "gentle," "sensitive," "organic," or "hypoallergenic" often contained MI, thus emphasizing the importance of consumer scrutiny of product choices. These findings reinforce the importance of educating parents and providing consumer decision-making advice regarding common skin care products, in order to help prevent ACD in children.
A cultural look at moral purity: wiping the face clean
Lee, Spike W. S.; Tang, Honghong; Wan, Jing; Mai, Xiaoqin; Liu, Chao
2015-01-01
Morality is associated with bodily purity in the custom of many societies. Does that imply moral purity is a universal psychological phenomenon? Empirically, it has never been examined, as all prior experimental data came from Western samples. Theoretically, we suggest the answer is not so straightforward—it depends on the kind of universality under consideration. Combining perspectives from cultural psychology and embodiment, we predict a culture-specific form of moral purification. Specifically, given East Asians' emphasis on the face as a representation of public self-image, we hypothesize that facial purification should have particularly potent moral effects in a face culture. Data show that face-cleaning (but not hands-cleaning) reduces guilt and regret most effectively against a salient East Asian cultural background. It frees East Asians from guilt-driven prosocial behavior. In the wake of their immorality, they find a face-cleaning product especially appealing and spontaneously choose to wipe their face clean. These patterns highlight both culturally variable and universal aspects of moral purification. They further suggest an organizing principle that informs the vigorous debate between embodied and amodal perspectives. PMID:26029134
Durkee, Jenna; Bartrem, Casey; Möller, Gregory
2017-02-01
From the early 1900s to the 1950s, Yakima Valley orchards were commonly treated with lead arsenate (LA) insecticides. Lead (Pb) and arsenic (As) soil contamination has been identified on former orchard lands throughout Central Washington and pose a threat to human health and the environment. The levels of Pb and As in soil and interior dust at participating childcare centers in the Upper Yakima Valley (Yakima County), Washington were sampled to explore exposure potential for young children. Childcare center soils were collected from two soil depths, homogenized, and analyzed in bulk by a field-portable X-ray fluorescence spectrometer (XRF). Interior dust wipes samples were collected from at least two locations in each facility. All soil samples >250 mg/kg Pb and/or >20 As mg/kg were sieved to 250 μm, tested by XRF a second time, and analyzed via acid digestion and inductively coupled plasma mass spectrometry (ICP-MS) analysis. Bulk and sieved XRF results, as well as ICP-MS to XRF results were strongly correlated. Maximum Pb and As XRF results indicated that 4 (21%) and 8 (42%) of the 19 childcare centers surveyed exceeded the regulatory standard for Pb and As, respectively. Historic land use was significantly associated with elevated Pb and As levels. Interior dust loadings were below United States Environmental Protection Agency (EPA) guidelines. Childcare centers are areas of intensive use for children and when coupled with potential residential exposure in their homes, the total daily exposure is a potential hazard to children. Copyright © 2016 Elsevier Ltd. All rights reserved.
Analysis of Nonvolatile Residue (NVR) from Spacecraft Systems
NASA Technical Reports Server (NTRS)
Colony, J. A.
1985-01-01
Organic contamination on critical spacecraft surfaces can cause electronic problems, serious attenuation of various optical signals, thermal control changes, and adhesion problems. Such contaminants can be detected early by the controlled use of witness mirrors, witness plates, wipe sampling, or direct solvent extraction. Each method requires careful control of variables of technique and materials to attain the ultimate sensitivities inherent to that procedure. Subsequent chemical analysis of the contaminant sample by infrared and mass spectrometry identifies the components, gives semiquantitative estimates of contaminant thickness, indicates possible sources of the nonvolatile residue (NVR), and provides guidance for effective cleanup procedures.
Tsurikisawa, Naomi; Saito, Akemi; Oshikata, Chiyako; Yasueda, Hiroshi; Akiyama, Kazuo
2016-10-01
We investigated the best strategy for adult asthmatics to avoid exposure to Dermatophagoides group (Der-1) allergens. Adult atopic asthmatics (n = 111) followed a 32-item checklist for avoiding Der-1 allergen exposure. Twenty-five patients were excluded through incomplete sampling; 50 remaining patients encased their pillows/futons/mattresses in microfine-fiber covers, 13 used vacuum cleaners with dust-mite-collection nozzles, and 23 acted as non-intervention controls. During August-October 2010 and August-October 2011, dust samples were collected in Petri dishes placed in bedrooms for 2 weeks and from mattresses/futons by using adhesive tape on one morning. A Der-1 level decrease was defined as a mean 2011 Der-1 level of <1 as a ratio of the 2010 level on tape or Petri dish samples. We analyzed the associations between Der-1 level change (by ELISA) and % weekly variability in peak expiratory flow (PEF) or fraction of exhaled nitric oxide (FeNO) after intervention. Der-1 levels decreased significantly in the covers group but not the vacuuming group. FeNO levels and PEF variability were unchanged in both groups. In patients whose Petri dish or tape samples showed decreased Der-1 levels, the % PEF variability was lower in 2011 than in 2010, but FeNO levels were unchanged. Three interventions (vacuuming all family members' mattress/futon surfaces at least weekly or after exposure of the futons to sunlight, and floor wiping before vacuuming), plus using covers, were the most effective management strategy in reducing Der-1 levels. This environmental and bedding maintenance program may help manage adult atopic asthma.
Moore, John E; Watabe, Miyuki; Stewart, Andrew; Cherie Millar, B; Rao, Juluri R
2009-01-01
Maturing compost heaps normally attaining temperatures ranging from 55 to 65 degrees C is generally regarded to conform to recommended biological risks and sanitation standards for composts stipulated by either EU or US-EPA. Composted products derived from animal sources are further required by EU biohazard safety regulatory legislation that such composts either attain 70 degrees C for over 3h during maturation or via treatment at 70 degrees C for 1h before being considered for dispensation on land. The setting of the upper limit of thermal lethality at 70 degrees C/1h for achieving biosecurity of the animal waste composted products (e.g. pelleted fertilizer formulations) is not properly substantiated by specific validation tests, comprising a 'wipe-out' step (usually via autoclaving) followed by inoculation of a prescribed bacterium, exposure to 70 degrees C/1h and the lethality determined. Pelleted formulations of composts are not amenable for wet methods (autoclaving) for wipe-out sterilization step as this is detrimental to the pellet and compromises sample integrity. This study describes a laboratory method involving the employment of ((60)Co) irradiation 'wipe-out' step to: (a) compost sub-samples drawn from compost formulation heaps and (b) pelleted products derived from composted animal products while determining the thermal lethality of a given time/temperature (70 degrees C/1h) treatment process and by challenging the irradiated sample (not just with one bacterium but), out with 10 potential food-poisoning organisms from the bacterial genera (Campylobacter, Escherichia, Listeria, Salmonella, Yersinia) frequently detected in pig and poultry farm wastes. This challenge test on compost sub-samples can be a useful intervention ploy for 'inspection and validation' technique for composters during the compost maturity process, whose attainment of temperatures of 55-65 degrees C is presumed sufficient for attainment of sanitation. Stringent measures are further required by law for composted products arising from rural industrialists producing pelleted fertilizers from re-composted animal agriculture wastes comprising pig slurry solids, poultry litter and spent mushroom compost, which carry residual food-borne pathogens with implications to the food chain including humans. Environmentally, sustainable means of recycling farm wastes require that final composted products are free of pathogens in compliance with environmental safety legislation before their release to the market. This test developed provides a science-based risk characterization tool for sustainably managing environmental safety by 'validating' thermal lethality of a given composting process or their derivatives achieved without compromising the sample integrity or ambiguity attached to microbiological validation involving steam sterilization or autoclaving procedures and helps audit the resurgent bacterial populations from surviving non-pathogenic organisms in the end-products of animal waste compost formulations.
[Biomechanical characteristics of the wiping reflex cycle].
Berkinblit, M B; Zharkova, I S; Fel'dman, A G; Fukson, O I
1984-01-01
Multijoint goal-directed hindlimb movements in response to chemical stimulation delivered to different skin sites on the medial back surface (wiping reflex-WR) were filmed and analysed in spinal or intact frogs Rana temporaria. Each WR cycle was divisible into five phases (flexion, lifting, aiming, wiping and extension) usually separated from each other by postural interruptions. One or several of the phases might spontaneously be reduced or deleted at all (e. g. the extension phase), although the WR was still effective. Such a reduction was, as a rule, observed in intact frogs while spinal ones usually exhibited the maximum phase sequence. It is suggested that the central spinal generator of the WR is formed of separate functional blocks each of which specifies a certain interjoint coordination and brings the joints to the central-conditioned equilibrium positions.
Corp, Nadia; Hayaki, Hitoshige; Matsusaka, Takahisa; Fujita, Shiho; Hosaka, Kazuhiko; Kutsukake, Nobuyuki; Nakamura, Michio; Nakamura, Miho; Nishie, Hitonaru; Shimada, Masaki; Zamma, Koichiro; Wallauer, William; Nishida, Toshisada
2009-04-01
In 1998, four chimpanzees in the Mahale Mountains National Park, Tanzania, were observed wiping their mouths with non-detached leaves or stalks of grass, or rubbing their mouths with a tree trunk or branch, especially while eating lemons. The number of mouth-wiping/rubbing individuals increased to 18 in 1999. By 2005, 29 chimpanzees were documented wiping/rubbing their muzzles in this way. Although it is difficult to determine whether the chimpanzees acquired this behavior as a result of trial and error or social learning, the fact that chimpanzees at other sites perform this behavior with detached leaves or leafy twigs much more often than with intact items suggests the possibility that cleaning with intact plant parts at Mahale spread via social learning.
Code of Federal Regulations, 2014 CFR
2014-07-01
... square foot) is washed for 1 minute. Wipe smooth surfaces with a cleaning solution-soaked disposable absorbent pad such that each 900 cm2 (1 square foot) is wiped for 1 minute. Wash any surface square foot... solution with 1 gallon of clean water per square foot and capture the rinse water. Mop up the wet surface...
Code of Federal Regulations, 2012 CFR
2012-07-01
... square foot) is washed for 1 minute. Wipe smooth surfaces with a cleaning solution-soaked disposable absorbent pad such that each 900 cm2 (1 square foot) is wiped for 1 minute. Wash any surface square foot... solution with 1 gallon of clean water per square foot and capture the rinse water. Mop up the wet surface...
Code of Federal Regulations, 2013 CFR
2013-07-01
... square foot) is washed for 1 minute. Wipe smooth surfaces with a cleaning solution-soaked disposable absorbent pad such that each 900 cm2 (1 square foot) is wiped for 1 minute. Wash any surface square foot... solution with 1 gallon of clean water per square foot and capture the rinse water. Mop up the wet surface...
Code of Federal Regulations, 2010 CFR
2010-07-01
... square foot) is washed for 1 minute. Wipe smooth surfaces with a cleaning solution-soaked disposable absorbent pad such that each 900 cm2 (1 square foot) is wiped for 1 minute. Wash any surface square foot... solution with 1 gallon of clean water per square foot and capture the rinse water. Mop up the wet surface...
Code of Federal Regulations, 2011 CFR
2011-07-01
... square foot) is washed for 1 minute. Wipe smooth surfaces with a cleaning solution-soaked disposable absorbent pad such that each 900 cm2 (1 square foot) is wiped for 1 minute. Wash any surface square foot... solution with 1 gallon of clean water per square foot and capture the rinse water. Mop up the wet surface...
Nonvolatile and Cryogenic-compatible Quantum Memory Devices (QuMEM)
2016-06-01
construction including: • 4” SiO2 /Si substrates and wafer/sample holders • Tweezers and wafer scribe • Safety glasses , gloves, and fab wipes • Probe tips...Cleaving of NbSe2 with Scotch™ Tape method ............................................................ 56 59. Transfer of NbSe2 atomic crystals to SiO2 ...O2 plasma + optional CF4 5 Top superconductor electrode evaporation Thermal Evaporation at SDSU MEMS Lab P+ Si Handle Wafer SiO2 (Oxide
Nonvolatile and Cryogenic-Compatible Quantum Memory Devices (QuMEM)
2016-06-01
construction including: • 4” SiO2 /Si substrates and wafer/sample holders • Tweezers and wafer scribe • Safety glasses , gloves, and fab wipes • Probe tips...Cleaving of NbSe2 with Scotch™ Tape method ............................................................ 56 59. Transfer of NbSe2 atomic crystals to SiO2 ...O2 plasma + optional CF4 5 Top superconductor electrode evaporation Thermal Evaporation at SDSU MEMS Lab P+ Si Handle Wafer SiO2 (Oxide
Larson, Elaine L; Cohen, Bevin; Baxter, Kathleen A
2012-11-01
Minimal research has been published evaluating the effectiveness of hand hygiene delivery systems (ie, rubs, foams, or wipes) at removing viruses from hands. The purposes of this study were to determine the effect of several alcohol-based hand sanitizers in removing influenza A (H1N1) virus, and to compare the effectiveness of foam, gel, and hand wipe products. Hands of 30 volunteers were inoculated with H1N1 and randomized to treatment with foam, gel, or hand wipe applied to half of each volunteer's finger pads. The log(10) count of each subject's treated and untreated finger pads were averaged. Log(10) reductions were calculated from these differences and averaged within treatment group. Between-treatment analysis compared changes from the untreated finger pads using analysis of covariance with treatment as a factor and the average log(10) untreated finger pads as the covariate. Log(10) counts on control finger pads were 2.7-5.3 log(10) of the 50% infectious dose for tissue culture (TCID(50)/0.1 mL) (mean, 3.8 ± 0.5 log(10) TCID(50)/0.1 mL), and treated finger pad counts for all test products were 0.5-1.9 log(10) TCID(50)/0.1 mL (mean, 0.53 ± 0.17 log(10) TCID(50)/0.1 mL). Treatments with all products resulted in a significant reduction in viral titers (>3 logs) at their respective exposure times that were statistically comparable. All 3 delivery systems (foam, gel, and wipe) produced significantly reduced viral counts on hands. Copyright © 2012 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.
Lutz, Jonathan K; van Balen, Joany; Crawford, John Mac; Wilkins, John R; Lee, Jiyoung; Nava-Hoet, Rocio C; Hoet, Armando E
2014-12-01
Little is known about the occurrence and epidemiology of methicillin-resistant Staphylococcus aureus (MRSA) in public transportation in the United States. This research sought to determine the background prevalence and phenotypic and genotypic characteristics of MRSA strains circulating on buses from a large, metropolitan transportation agency. Electrostatic wipes were used to collect 237 surface samples from 40 buses randomly selected from July-October 2010. Six samples were collected from each bus immediately postservice and before any cleaning and disinfection. Positive isolates were analyzed for antibiotic resistance, staphylococcal cassette chromosome mec (SCCmec) type, and pulsed-field gel electrophoresis; and potential epidemiologic factors were examined. Of the buses, 68% (27/40) were contaminated with S aureus, and 63% (25/40) were contaminated with MRSA. Seats and seat rails were the surfaces most frequently contaminated, followed by the back door and stanchions. Most (62.9%) of the MRSA isolates were classified as community-associated MRSA clones (SCCmec type IV), and 22.9% were health care-associated MRSA clones (SCCmec type II). Of the MRSA strains, 65% (5/20) were multidrug resistant. MRSA was frequently isolated from commonly touched surfaces in buses serving both hospital and community routes. Phenotypic and genotypic analysis demonstrated that buses may be effective mixing vessels for MRSA strains of both community and health care-associated origin. Copyright © 2014 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
Fenske, Richard A.; Bradman, Asa; Whyatt, Robin M.; Wolff, Mary S.; Barr, Dana B.
2005-01-01
In this article we examine sampling strategies and analytical methods used in a series of recent studies of children’s exposure to pesticides that may prove useful in the design and implementation of the National Children’s Study. We focus primarily on the experiences of four of the National Institute of Environmental Health Sciences/U.S. Environmental Protection Agency/ Children’s Centers and include University of Washington studies that predated these centers. These studies have measured maternal exposures, perinatal exposures, infant and toddler exposures, and exposure among young children through biologic monitoring, personal sampling, and environmental monitoring. Biologic monitoring appears to be the best available method for assessment of children’s exposure to pesticides, with some limitations. It is likely that a combination of biomarkers, environmental measurements, and questionnaires will be needed after careful consideration of the specific hypotheses posed by investigators and the limitations of each exposure metric. The value of environmental measurements, such as surface and toy wipes and indoor air or house dust samples, deserves further investigation. Emphasis on personal rather than environmental sampling in conjunction with urine or blood sampling is likely to be most effective at classifying exposure. For infants and young children, ease of urine collection (possible for extended periods of time) may make these samples the best available approach to capturing exposure variability of nonpersistent pesticides; additional validation studies are needed. Saliva measurements of pesticides, if feasible, would overcome the limitations of urinary metabolite-based exposure analysis. Global positioning system technology appears promising in the delineation of children’s time–location patterns. PMID:16203262
Methylisothiazolinone: An Emergent Allergen in Common Pediatric Skin Care Products
Schlichte, Megan J.
2014-01-01
Recalcitrant dermatitis, such as that of the hands, face, or genitals, may be due to allergic contact dermatitis (ACD) from ingredients in seemingly innocuous personal care products. Rising rates of allergy have been noted due to the preservative methylisothiazolinone (MI). This preservative is commonly found in skin and hair care products, especially wipes. This study evaluated the use of MI in products specifically marketed for babies and children and examined the associated marketing terms of such products. Ingredients of skin care products specifically marketed for babies and children were surveyed at two major retailers. Of 152 products surveyed, 30 products contained MI. Categories of products surveyed included facial or body wipes, antibacterial hand wipes, hair products, soaps, bubble baths, moisturizers, and sunscreens. Facial or body wipes and hair products were the categories with the greatest number of MI-containing products. MI-containing products were manufactured by a number of popular brands. Of note, products marketed as “gentle,” “sensitive,” “organic,” or “hypoallergenic” often contained MI, thus emphasizing the importance of consumer scrutiny of product choices. These findings reinforce the importance of educating parents and providing consumer decision-making advice regarding common skin care products, in order to help prevent ACD in children. PMID:25342949
Waste Management System overview for future spacecraft.
NASA Technical Reports Server (NTRS)
Ingelfinger, A. L.; Murray, R. W.
1973-01-01
Waste Management Systems (WMS) for post Apollo spacecraft will be significantly more sophisticated and earthlike in user procedures. Some of the features of the advanced WMS will be accommodation of both males and females, automatic operation, either tissue wipe or anal wash, measurement and sampling of urine, feces and vomitus for medical analysis, water recovery, and solids disposal. This paper presents an overview of the major problems of and approaches to waste management for future spacecraft. Some of the processes discussed are liquid/gas separation, the Dry-John, the Hydro-John, automated sampling, vapor compression distillation, vacuum distillation-catalytic oxidation, incineration, and the integration of the above into complete systems.
Cleaning of Filtering Facepiece Respirators Contaminated with Mucin and Staphylococcus aureus
2012-11-01
Journal of Infection Control. Document contains color images. Decontamination and reuse of filtering facepiece respirators (FFRs) has been proposed to...in the area of cleaning FFRs. This study evaluates the cleaning of three surgical N95 FFRs by three commercial wipe products as an initial exploration...significantly higher penetration than the other wipe products. The significance of these data to the concept of decontamination and reuse of FFRs will remain
Improving efficiency, reducing infection, and enhancing experience.
Massa, Judith
For health professionals to make an informed choice and tailor each bed bath to the individual needs of the patient, they must firstly understand the different bed bath options available, their impact on skin integrity, and any associated risks they may pose to the patient in terms of cross-infection. Only with this knowledge can health professionals determine the appropriate form and frequency of the bed bath. Specialist wipes offer significant improvements in skin care and a reduced risk of cross-infection, compared with the traditional soap and water bed bath. Use of these wipes also improves the efficiency of the process, which links to the Productive Ward Initiative and results in clinical staff (i.e. nursing staff, healthcare assistants) having more time available to undertake additional patient care activities. This product focus highlights the benefits of moving to a wipe-based bed bath method, and the significant efficiency savings that can be realized as a result.
Environmentally compatible hand wipe cleaning solvents
NASA Technical Reports Server (NTRS)
Clayton, Catherine P.; Kovach, Michael P.
1995-01-01
Several solvents of environmental concern have previously been used for hand wipe cleaning of SRB surfaces, including 1,1,1-trichloroethane, perchloroethylene, toluene, xylene, and MEK. USBI determined the major types of surfaces involved, and qualification requirements of replacement cleaning agents. Nineteen environmentally compatible candidates were tested on 33 material substrates with 26 types of potential surface contaminants, involving over 7,000 individual evaluations. In addition to the cleaning performance evaluation, bonding, compatibility, and corrosion tests were conducted. Results showed that one cleaner was not optimum for all surfaces. In most instances, some of the candidates cleaned better than the 1,1,1-trichloroethane baseline control. Aqueous cleaners generally cleaned better, and were more compatible with nonmetallic materials, such as paints, plastics, and elastomers. Organic base cleaners were better on metal surfaces. Five cleaners have been qualified and are now being implemented in SRB hand wipe cleaning operations.
Engelhart, Steffen; Exner, Martin; Simon, Arne
2015-01-01
This in vitro study investigated the external disinfection of two needle-free connection devices (NFC) using Octeniderm® (spraying and wiping technique) vs. Descoderm® pads (wiping technique). The split-septum membrane of the NFC was contaminated with >105 CFU K. pneumoniae or S. epidermidis. The efficacy of the disinfection at 30 sec. exposure time was controlled by taking a swab sample and by flushing the NFC with sterile 0.9% sodium chloride solution. Disinfection with octenidine dihydrochloride 0.1 g, 1-Propanol 30.0 g, and 2-Propanol 45.0 g in 100 g solution was highly effective (CFU reduction ≥4 log) against both microorganisms, whereas the use of 63.1 g 2-Propanol in 100 ml solution led to residual contamination with S. epidermidis. Our investigation underlines that (i) in clinical practice disinfection of NFCs before use is mandatory, and that (ii) details of disinfection technique are of utmost importance regarding their efficacy. Our investigation revealed no significant differences between both split-septum NFC types. Clinical studies are needed to confirm a possible superiority of disinfectants with long-lasting residual antimicrobial activity. PMID:26693394
Biomonitoring of N-ethyl-2-pyrrolidone in automobile varnishers.
Koslitz, Stephan; Meier, Swetlana; Schindler, Birgit Karin; Weiss, Tobias; Koch, Holger Martin; Brüning, Thomas; Käfferlein, Heiko Udo
2014-12-01
N-alkyl-2-pyrrolidones are important organic solvents for varnishes in industry. This study investigates exposure to N-ethyl-2-pyrrolidone (NEP) in varnishing of hard plastic components in an automobile plant. Two specific biomarkers of exposure, 5-hydroxy-N-ethyl-2-pyrrolidone (5-HNEP) and 2-hydroxy-N-ethylsuccinimide (2-HESI), were analyzed in urine samples of 14 workers. For this purpose, pre-shift, post-shift and next day pre-shift urine samples were collected midweek. Twelve workers performed regular work tasks (loading, wiping and packing), whereas two workers performed special work tasks including cleaning the sprayer system with organic solvents containing N-alkyl-2-pyrrolidones. Spot urine samples of nine non-exposed persons of the same plant served as controls. Median post-shift urinary levels of workers with regular work tasks (5-HNEP: 0.15 mg/L; 2-HESI: 0.19 mg/L) were ∼5-fold higher compared to the controls (0.03 mg/L each). Continuously increasing metabolite levels, from pre-shift via post-shift to pre-shift samples of the following day, were observed in particular for the two workers with the special working tasks. Maximum levels were 31.01 mg/L (5-HNEP) and 8.45 mg/L (2-HESI). No clear trend was evident for workers with regular working tasks. In summary, we were able to show that workers can be exposed to NEP during varnishing tasks in the automobile industry. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Gallagher, R. Scott; Purvis, John A.; Moran, Wade W.
1995-01-01
Engineers at Hercules Aerospace, a rocket motor manufacturer in Utah, have worked closely with chemists at Glidco Organics to study the feasibility of using terpenes for zero-residue wipe cleaning. The result of this work is a technological breakthrough, in which the barrier to ultra-low non-volatile residue formation has been broken. After 2 years of development and testing, SCM Glidco Organics has announced the availability of Glidsafe(registered trademark) Prepsolv(TM): a state-of-the-art ultra-low residue terpene wipe cleaning agent that does not require rinsing. Prepsolv(TM) can successfully be used in simple hand-wipe cleaning processes without fear of leaving surface residues. Industry testing has confirmed that Prepsolv(TM) is not only highly effective, but can even be less expensive to use than traditional cleaning solvents like methyl chloroform. This paper addresses the features and benefits of Prepsolv(TM), and presents performance and material compatibility data that characterizes this unique cleaning agent. Since its commercialization, Hercules Aerospace has chosen Prepsolv(TM) as the optimum cleaning agent to replace ozone-depleting solvents in their weapons factory in Magna, UT. Likewise, Boeing has approved Prepsolv(TM) for cleaning components in the manufacture of commercial aircraft at their facilities in Seattle, WA and Wichita, KS. Additional approvals are forthcoming for this uniquely safe and effective solvent.
Field applications of ion-mobility spectrometry
NASA Astrophysics Data System (ADS)
Brown, Patricia A.
1997-02-01
Ion mobility spectrometry (IMS) is an excellent tool for detection of controlled substances under field conditions. Plasmagrams and tables showing the results of field applications will be discussed. Residues of drugs, such as cocaine and heroin, can be left anywhere including vehicles, boats, and houses. In houses, the carpets, walls, and floors are good locations for residues to adhere. Individual clothing can also be contaminated with drug residue. Vehicles that are suspected of having previously smuggled illegal substances can be vacuumed and screened. Tablets that look similar and respond the same when screened with the Marquis reagent can be differentiated by IMS. With Southern California being the 'methamphetamine capital of the world' and the resurgence of phencyclidine, IMS has proven extremely valuable in the screening of abandoned clandestine laboratory sites and vehicles in which the clandestine laboratories; chemicals and glassware were transported. IMS is very responsive to ephedrine/pseudophedrine, a precursor of methamphetamine and 1-piperidinocyclohexanecarbonitrile, an intermediate of phencyclidine. Once residues are detected, vacuum samples, and/or methanol wipes are collected and analyzed at the DEA Laboratory for confirmation of the suspected substance using GC-IRD or Mass Spectrometry.
Lee, David; Treffiletti, Aimee; Hrsak, Mario; Shugart, Jill; Vinjé, Jan
2015-01-01
Inanimate surfaces are regarded as key vehicles for the spread of human norovirus during outbreaks. ISO method 15216 involves the use of cotton swabs for environmental sampling from food surfaces and fomites for the detection of norovirus genogroup I (GI) and GII. We evaluated the effects of the virus drying time (1, 8, 24, or 48 h), swab material (cotton, polyester, rayon, macrofoam, or an antistatic wipe), surface (stainless steel or a toilet seat), and area of the swabbed surface (25.8 cm2 to 645.0 cm2) on the recovery of human norovirus. Macrofoam swabs produced the highest rate of recovery of norovirus from surfaces as large as 645 cm2. The rates of recovery ranged from 2.2 to 36.0% for virus seeded on stainless-steel coupons (645.0 cm2) to 1.2 to 33.6% for toilet seat surfaces (700 cm2), with detection limits of 3.5 log10 and 4.0 log10 RNA copies. We used macrofoam swabs to collect environmental samples from several case cabins and common areas of a cruise ship where passengers had reported viral gastroenteritis symptoms. Seventeen (18.5%) of 92 samples tested positive for norovirus GII, and 4 samples could be sequenced and had identical GII.1 sequences. The viral loads of the swab samples from the cabins of the sick passengers ranged from 80 to 31,217 RNA copies, compared with 16 to 113 RNA copies for swab samples from public spaces. In conclusion, our swab protocol for norovirus may be a useful tool for outbreak investigations when no clinical samples are available to confirm the etiology. PMID:26116675
Wenzel, A; Kornum, F; Knudsen, MR; Lau, E Frandsen
2013-01-01
Objectives: To assess (1) antimicrobial efficiency of wiping intraoral phosphor plates with alcohol tissues based on ethanol or 2-propanol alcohols after contamination with Candida albicans and Streptococcus oralis, (2) a concept for autodisinfection with ultraviolet light of the transport ramp in a scanner for phosphor plates and (3) the impact of wiping with alcohol tissues on durability of the plate. Methods: Suspensions of C. albicans and S. oralis were prepared in concentrations of 109 and 105 organisms per ml, and Digora (Digora® Optime Imaging Plate, size 2; Soredex, PalaDEx Group Brenntag Nordic A/S, Hellerup, Denmark) and Vista (VistaScan® Imaging Plate PLUS, size 2; Dürr Dental AG, Bietigheim-Bissingen, Germany) plates were contaminated. The plates were wiped with ethanol or 2-propanol disinfectant tissues and imprints obtained on agar. Number of microbial colonies after culturing was recorded. The scanner ramp was contaminated with C. albicans or S. oralis, respectively, the ultraviolet light (UV light) disinfection in the scanner was activated and the number of colonies after culturing was recorded. Plates from each system were sequentially wiped (5–60 times) with ethanol and 2-propanol, exposed and scanned. 48 images from each system were scored blind: 1 = no artefact, 2 = small artefacts and 3 = severe artefacts. Results: Ethanol eliminated C. albicans and S. oralis in high and low concentrations from both types of plates, whereas 2-propanol did not eliminate all micro-organisms at high concentrations. The UV light eliminated all micro-organisms from the ramp. Ethanol degraded the plates to a larger extent than did 2-propanol. Images from Vista plates showed severe artefacts after wiping with ethanol; those from Digora plates did not. Conclusions: Ethanol eliminated all micro-organisms but degraded phosphor plates, whereas 2-propanol did not eliminate all micro-organisms and still degraded plates from Vista but not from Digora. PMID:23420856
Wenzel, A; Kornum, F; Knudsen, Mr; Lau, E Frandsen
2013-01-01
To assess (1) antimicrobial efficiency of wiping intraoral phosphor plates with alcohol tissues based on ethanol or 2-propanol alcohols after contamination with Candida albicans and Streptococcus oralis, (2) a concept for autodisinfection with ultraviolet light of the transport ramp in a scanner for phosphor plates and (3) the impact of wiping with alcohol tissues on durability of the plate. Suspensions of C. albicans and S. oralis were prepared in concentrations of 10(9) and 10(5) organisms per ml, and Digora (Digora(®) Optime Imaging Plate, size 2; Soredex, PalaDEx Group Brenntag Nordic A/S, Hellerup, Denmark) and Vista (VistaScan(®) Imaging Plate PLUS, size 2; Dürr Dental AG, Bietigheim-Bissingen, Germany) plates were contaminated. The plates were wiped with ethanol or 2-propanol disinfectant tissues and imprints obtained on agar. Number of microbial colonies after culturing was recorded. The scanner ramp was contaminated with C. albicans or S. oralis, respectively, the ultraviolet light (UV light) disinfection in the scanner was activated and the number of colonies after culturing was recorded. Plates from each system were sequentially wiped (5-60 times) with ethanol and 2-propanol, exposed and scanned. 48 images from each system were scored blind: 1 = no artefact, 2 = small artefacts and 3 = severe artefacts. Ethanol eliminated C. albicans and S. oralis in high and low concentrations from both types of plates, whereas 2-propanol did not eliminate all micro-organisms at high concentrations. The UV light eliminated all micro-organisms from the ramp. Ethanol degraded the plates to a larger extent than did 2-propanol. Images from Vista plates showed severe artefacts after wiping with ethanol; those from Digora plates did not. Ethanol eliminated all micro-organisms but degraded phosphor plates, whereas 2-propanol did not eliminate all micro-organisms and still degraded plates from Vista but not from Digora.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Szrom, Fran; Falo, Gerald A.; Lodde, Gordon M.
2009-03-01
Depleted uranium (DU) intake rates and subsequent dose rates were estimated for personnel entering armored combat vehicles perforated with DU penetrators (level II and level III personnel) using data generated during the Capstone Depleted Uranium (DU) Aerosol Study. Inhalation intake rates and associated dose rates were estimated from cascade impactors worn by sample recovery personnel and from cascade impactors that served as area monitors. Ingestion intake rates and associated dose rates were estimated from cotton gloves worn by sample recovery personnel and from wipe test samples from the interior of vehicles perforated with large caliber DU munitions. The mean DUmore » inhalation intake rate for level II personnel ranged from 0.447 mg h-1 based on breathing zone monitor data (in and around a perforated vehicle) to 14.5 mg h-1 based on area monitor data (in a perforated vehicle). The mean DU ingestion intake rate for level II ranged from 4.8 mg h-1 to 38.9 mg h-1 based on the wipe test data including surface to glove transfer factors derived from the Capstone data. Based on glove contamination data, the mean DU ingestion intake rates for level II and level III personnel were 10.6 mg h-1 was and 1.78 mg h-1, respectively. Effective dose rates and peak kidney uranium concentration rates were calculated based on the intake rates. The peak kidney uranium concentration rate cannot be multiplied by the total exposure duration when multiple intakes occur because uranium will clear from the kidney between the exposures.« less
Probst, Alexander; Facius, Rainer; Wirth, Reinhard; Wolf, Marco; Moissl-Eichinger, Christine
2011-01-01
Microbial contaminants on spacecraft can threaten the scientific integrity of space missions due to probable interference with life detection experiments. Therefore, space agencies measure the cultivable spore load (“bioburden”) of a spacecraft. A recent study has reported an insufficient recovery of Bacillus atrophaeus spores from Vectran fabric, a typical spacecraft airbag material (A. Probst, R. Facius, R. Wirth, and C. Moissl-Eichinger, Appl. Environ. Microbiol. 76:5148-5158, 2010). Here, 10 different sampling methods were compared for B. atrophaeus spore recovery from this rough textile, revealing significantly different efficiencies (0.5 to 15.4%). The most efficient method, based on the wipe-rinse technique (foam-spatula protocol; 13.2% efficiency), was then compared to the current European Space Agency (ESA) standard wipe assay in sampling four different kinds of spacecraft-related surfaces. Results indicate that the novel protocol out-performed the standard method with an average efficiency of 41.1% compared to 13.9% for the standard method. Additional experiments were performed by sampling Vectran fabric seeded with seven different spore concentrations and five different Bacillus species (B. atrophaeus, B. anthracis Sterne, B. megaterium, B. thuringiensis, and B. safensis). Among these, B. atrophaeus spores were recovered with the highest (13.2%) efficiency and B. anthracis Sterne spores were recovered with the lowest (0.3%) efficiency. Different inoculation methods of seeding spores on test surfaces (spotting and aerosolization) resulted in different spore recovery efficiencies. The results of this study provide a step forward in understanding the spore distribution on and recovery from rough surfaces. The results presented will contribute relevant knowledge to the fields of astrobiology and B. anthracis research. PMID:21216908
Nishioka, M G; Lewis, R G; Brinkman, M C; Burkholder, H M; Hines, C E; Menkedick, J R
2001-01-01
We collected indoor air, surface wipes (floors, table tops, and window sills), and floor dust samples at multiple locations within 11 occupied and two unoccupied homes both before and after lawn application of the herbicide 2,4-D. We measured residues 1 week before and after application. We used collected samples to determine transport routes of 2,4-D from the lawn into the homes, its subsequent distribution between the indoor surfaces, and air concentration as a function of airborne particle size. We used residue measurements to estimate potential exposures within these homes. After lawn application, 2,4-D was detected in indoor air and on all surfaces throughout all homes. Track-in by an active dog and by the homeowner applicator were the most significant factors for intrusion. Resuspension of floor dust was the major source of 2,4-D in indoor air, with highest levels of 2,4-D found in the particle size range of 2.5-10 microm. Resuspended floor dust was also a major source of 2,4-D on tables and window sills. Estimated postapplication indoor exposure levels for young children from nondietary ingestion may be 1-10 microg/day from contact with floors, and 0.2-30 microg/day from contact with table tops. These are estimated to be about 10 times higher than the preapplication exposures. By comparison, dietary ingestion of 2,4-D is approximately 1.3 microg/day. PMID:11713005
NASA Technical Reports Server (NTRS)
Swider, J. E., Jr.
1974-01-01
The zero gravity test program demonstrated the feasibility and practicability of collecting urine from both male and female crew members in a zero gravity environment in an earthlike manner not requiring any manual handling of urine containers. In addition, the testing demonstrated that a seat which is comfortable in both regimes of operation could be designed for use on the ground and in zero-gravity. Further, the tests showed that the vortex liquid/air separator is an effective liquid/air separation method in zero gravity. Visual observations indicate essentially zero liquid carry over. The system also demonstrated its ability to handle post elimination wipes without difficulty. The designs utilized in the WCS were verified as acceptable for usage in the space shuttle or other space vehicles.
The inability to screen exhibition swine for influenza A virus using body temperature
Bowman, Andrew S.; Nolting, Jacqueline M.; Workman, Jeffrey D.; Cooper, Maria; Fisher, Aaron E; Marsh, Bret; Forshey, Tony
2015-01-01
Summary Agricultural fairs create an unconventional animal-human interface that has been associated with swine-to-human transmission of influenza A virus (IAV) in recent years. Early detection of IAV-infected pigs at agricultural fairs would allow veterinarians to better protect swine and human health during these swine exhibitions. The present study assessed the use of swine body temperature measurement, recorded by infrared and rectal thermometers, as a practical method to detect IAV-infected swine at agricultural fairs. In our first objective, infrared thermometers were used to record the body surface temperature of 1,092 pigs at the time of IAV nasal swab collection at the end of the exhibition period of 55 agricultural fairs. IAV was recovered from 212 (19.4%) pigs and the difference in mean infrared body temperature measurement of IAV-positive and negative pigs was 0.83°C. In a second objective, snout wipes were collected from 1,948 pigs immediately prior to the unloading of the animals at a single large swine exhibition. Concurrent to the snout wipe collection, owners took the rectal temperatures of his/her pigs. In this case, 47 (2.4%) pigs tested positive for IAV before they entered the swine barn. The mean rectal temperatures differed by only 0.19°C between IAV-positive and negative pigs. The low prevalence of IAV among the pigs upon entry to the fair in the second objective provides evidence that limiting intra-species spread of IAV during the fairs will likely have significant impacts on the zoonotic transmission. However, in both objectives, the high degree of similarity in the body temperature measurements between the IAV-positive and negative pigs made it impossible to set a diagnostically meaningful cut point to differentiate IAV status of the individual animals. Unfortunately, body temperature measurement cannot be used to accurately screen exhibition swine for IAV. PMID:25884907
The Inability to Screen Exhibition Swine for Influenza A Virus Using Body Temperature.
Bowman, A S; Nolting, J M; Workman, J D; Cooper, M; Fisher, A E; Marsh, B; Forshey, T
2016-02-01
Agricultural fairs create an unconventional animal-human interface that has been associated with swine-to-human transmission of influenza A virus (IAV) in recent years. Early detection of IAV-infected pigs at agricultural fairs would allow veterinarians to better protect swine and human health during these swine exhibitions. This study assessed the use of swine body temperature measurement, recorded by infrared and rectal thermometers, as a practical method to detect IAV-infected swine at agricultural fairs. In our first objective, infrared thermometers were used to record the body surface temperature of 1,092 pigs at the time of IAV nasal swab collection at the end of the exhibition period of 55 agricultural fairs. IAV was recovered from 212 (19.4%) pigs, and the difference in mean infrared body temperature measurement of IAV-positive and IAV-negative pigs was 0.83°C. In a second objective, snout wipes were collected from 1,948 pigs immediately prior to the unloading of the animals at a single large swine exhibition. Concurrent to the snout wipe collection, owners took the rectal temperatures of his/her pigs. In this case, 47 (2.4%) pigs tested positive for IAV before they entered the swine barn. The mean rectal temperatures differed by only 0.19°C between IAV-positive and IAV-negative pigs. The low prevalence of IAV among the pigs upon entry to the fair in the second objective provides evidence that limiting intraspecies spread of IAV during the fairs will likely have significant impacts on the zoonotic transmission. However, in both objectives, the high degree of similarity in the body temperature measurements between the IAV-positive and IAV-negative pigs made it impossible to set a diagnostically meaningful cut point to differentiate IAV status of the individual animals. Unfortunately, body temperature measurement cannot be used to accurately screen exhibition swine for IAV. © 2015 Blackwell Verlag GmbH.
Characterizing the recovery of a solid surface after tungsten nano-tendril formation
NASA Astrophysics Data System (ADS)
Wright, G. M.; van Eden, G. G.; Kesler, L. A.; De Temmerman, G.; Whyte, D. G.; Woller, K. B.
2015-08-01
Recovery of a flat tungsten surface from a nano-tendril surface is attempted through three techniques; a mechanical wipe, a 1673 K annealing, and laser-induced thermal transients. Results were determined through SEM imaging and elastic recoil detection to assess the helium content in the surface. The mechanical wipe leaves a ∼0.5 μm deep layer of nano-tendrils on the surface post-wipe regardless of the initial nano-tendril layer depth. Laser-induced thermal transients only significantly impact the surface morphology at heat loads of 35.2 MJ/m2 s1/2 or above, however a fully flat or recovered surface was not achieved for 100 transients at this heat load despite reducing the helium content by a factor of ∼7. A 1673 K annealing removes all detectable levels of helium but sub-surface voids/bubbles remain intact. The surface is recovered to a nearly flat state with only some remnants of nano-tendrils re-integrating into the surface remaining.
Results of Testing the Relative Oxidizing Hazard of Wipes and KMI Zeolite
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ams, Bridget Elaine
This report includes the results from testing performed on the relative oxidizing hazard of a number of organic sorbing wipe materials, as well as KMI zeolite. These studies were undertaken to address a need by the Los Alamos National Laboratory (LANL) Hazardous Materials Management group, which requires a material that can sorb small spills in a glovebox without creating a disposal hazard due to the potential for oxidation reactions, as requested in Request for Testing of Wipes and Zeolite for Los Alamos National Laboratory Hazardous Materials Group (NPl-7) (NPl-7-17-002) and Request for Testing of Chamois Material for Los Alamos Nationalmore » Laboratory Hazardous Materials Group (NPl-7) (NPl-7-17-005). This set oftests is a continuation of previous testing described in Results from Preparation and Testing of Sorbents Mixed with (DWT-RPT-003), which provided data for the Waste Isolation Pilot Plant's Basis of Knowledge. The Basis of Knowledge establishes criteria for evaluating transuranic (TRU) waste that contains oxidizing chemicals.« less
NASA Technical Reports Server (NTRS)
Brown, Patricia A.; Comparin, Jeffrey H.
1995-01-01
Clandestine methamphetamine laboratories are prevalent in southern California. The most common encountered synthesis results in vapor release, and drug residue being left behind. The suspected manufacturing area can be vacuumed and/or methanol wiped and screened immediately at the lab site using the Ionscan. Positive results are confirmed by obtaining vacuum sweep samples with subsequent analysis at the DEA Laboratory. This procedure has been utilized successfully for identifying methamphetamine and ephedrine from clandestine laboratories that have been abandoned and/or remodeled.
Lin, Wen-Ye; Chang, Jung-Tzu; Chu, Chun-Feng
2017-01-01
Despite measures to reduce disease transmission, a risk can occur when blood glucose meters (BGMs) are used on multiple individuals or by caregivers assisting a patient. The laboratory and in-clinic performance of a BGM system before and after disinfection should be demonstrated to guarantee accurate readings and reliable control of blood glucose (BG) for patients. In this study, an effective disinfection procedure, conducting wiping 10 times to assure a one minute contact time of the disinfectant on contaminated surface, was first demonstrated using test samples of the meter housing materials, including acrylonitrile butadiene styrene (ABS), polymethyl methacrylate (PMMA), and polycarbonate (PC), in accordance with ISO 15197:2013. After bench studies comprising 10,000 disinfection cycles, the elemental compositions of the disinfected ABS, PMMA, and PC samples were almost the same as in the original samples, as indicated by electron spectroscopy for chemical analysis. Subsequently, the validated disinfection procedure was then directly applied to disinfect 5 commercial BGM systems composed of ABS, PMMA, or PC to observe the effect of the validated disinfection procedure on meter accuracy. The results of HBsAg values after treatment with HBV sera and disinfectant wipes for each material were less than the LoD of each material of 0.020 IU/mL. Before and after the multiple disinfection cycles, 900 of 900 samples (100%) were within the system accuracy requirements of ISO 15197:2013. All of the systems showed high performance before and after the series of disinfection cycles and met the ISO 15197:2013 requirements. In addition, our results demonstrated multiple cleaning and disinfection cycles that represented normal use over the lifetime of a meter of 3–5 years. Our validated cleaning and disinfection procedure can be directly applied to other registered disinfectants for cleaning commercial BGM products in the future. PMID:28683148
Veggie ISS Validation Test Results and Produce Consumption
NASA Technical Reports Server (NTRS)
Massa, Gioia; Hummerick, Mary; Spencer, LaShelle; Smith, Trent
2015-01-01
The Veggie vegetable production system flew to the International Space Station (ISS) in the spring of 2014. The first set of plants, Outredgeous red romaine lettuce, was grown, harvested, frozen, and returned to Earth in October. Ground control and flight plant tissue was sub-sectioned for microbial analysis, anthocyanin antioxidant phenolic analysis, and elemental analysis. Microbial analysis was also performed on samples swabbed on orbit from plants, Veggie bellows, and plant pillow surfaces, on water samples, and on samples of roots, media, and wick material from two returned plant pillows. Microbial levels of plants were comparable to ground controls, with some differences in community composition. The range in aerobic bacterial plate counts between individual plants was much greater in the ground controls than in flight plants. No pathogens were found. Anthocyanin concentrations were the same between ground and flight plants, while antioxidant and phenolic levels were slightly higher in flight plants. Elements varied, but key target elements for astronaut nutrition were similar between ground and flight plants. Aerobic plate counts of the flight plant pillow components were significantly higher than ground controls. Surface swab samples showed low microbial counts, with most below detection limits. Flight plant microbial levels were less than bacterial guidelines set for non-thermostabalized food and near or below those for fungi. These guidelines are not for fresh produce but are the closest approximate standards. Forward work includes the development of standards for space-grown produce. A produce consumption strategy for Veggie on ISS includes pre-flight assessments of all crops to down select candidates, wiping flight-grown plants with sanitizing food wipes, and regular Veggie hardware cleaning and microbial monitoring. Produce then could be consumed by astronauts, however some plant material would be reserved and returned for analysis. Implementation of this plan is a step toward developing pick-and-eat food production to supplement the packaged diet on ISS and for future exploration missions where plants could make up a larger portion of the diet. Supported by NASA Space Biology Program.
Lin, Shu-Ping; Lin, Wen-Ye; Chang, Jung-Tzu; Chu, Chun-Feng
2017-01-01
Despite measures to reduce disease transmission, a risk can occur when blood glucose meters (BGMs) are used on multiple individuals or by caregivers assisting a patient. The laboratory and in-clinic performance of a BGM system before and after disinfection should be demonstrated to guarantee accurate readings and reliable control of blood glucose (BG) for patients. In this study, an effective disinfection procedure, conducting wiping 10 times to assure a one minute contact time of the disinfectant on contaminated surface, was first demonstrated using test samples of the meter housing materials, including acrylonitrile butadiene styrene (ABS), polymethyl methacrylate (PMMA), and polycarbonate (PC), in accordance with ISO 15197:2013. After bench studies comprising 10,000 disinfection cycles, the elemental compositions of the disinfected ABS, PMMA, and PC samples were almost the same as in the original samples, as indicated by electron spectroscopy for chemical analysis. Subsequently, the validated disinfection procedure was then directly applied to disinfect 5 commercial BGM systems composed of ABS, PMMA, or PC to observe the effect of the validated disinfection procedure on meter accuracy. The results of HBsAg values after treatment with HBV sera and disinfectant wipes for each material were less than the LoD of each material of 0.020 IU/mL. Before and after the multiple disinfection cycles, 900 of 900 samples (100%) were within the system accuracy requirements of ISO 15197:2013. All of the systems showed high performance before and after the series of disinfection cycles and met the ISO 15197:2013 requirements. In addition, our results demonstrated multiple cleaning and disinfection cycles that represented normal use over the lifetime of a meter of 3-5 years. Our validated cleaning and disinfection procedure can be directly applied to other registered disinfectants for cleaning commercial BGM products in the future.
Corrigan, Damion K; Piletsky, Sergey; McCrossen, Sean
2009-01-01
This article compares the technical performances of several different commercially available swabbing materials for the purpose of cleaning verification. A steel surface was soiled with solutions of acetaminophen, nicotinic acid, diclofenac, and benzamidine and wiped with each swabbing material. The compounds were extracted with water or ethanol (depending on polarity of analyte) and their concentration in extract was quantified spectrophotometrically. The study also investigated swab debris on the wiped surface. The swab performances were compared and the best swab material was identified.
Contamination of dried blood spots - an underestimated risk in newborn screening.
Winter, Theresa; Lange, Anja; Hannemann, Anke; Nauck, Matthias; Müller, Cornelia
2018-01-26
Newborn screening (NBS) is an established screening procedure in many countries worldwide, aiming at the early detection of inborn errors of metabolism. For decades, dried blood spots have been the standard specimen for NBS. The procedure of blood collection is well described and standardized and includes many critical pre-analytical steps. We examined the impact of contamination of some anticipated common substances on NBS results obtained from dry spot samples. This possible pre-analytical source of uncertainty has been poorly examined in the past. Capillary blood was obtained from 15 adult volunteers and applied to 10 screening filter papers per volunteer. Nine filter papers were contaminated without visible trace. The contaminants were baby diaper rash cream, baby wet wipes, disinfectant, liquid infant formula, liquid infant formula hypoallergenic (HA), ultrasonic gel, breast milk, feces, and urine. The differences between control and contaminated samples were evaluated for 45 NBS quantities. We estimated if the contaminations might lead to false-positive NBS results. Eight of nine investigated contaminants significantly altered NBS analyte concentrations and potentially caused false-positive screening outcomes. A contamination with feces was most influential, affecting 24 of 45 tested analytes followed by liquid infant formula (HA) and urine, affecting 19 and 13 of 45 analytes, respectively. A contamination of filter paper samples can have a substantial effect on the NBS results. Our results underline the importance of good pre-analytical training to make the staff aware of the threat and ensure reliable screening results.
Broiler carcass contamination with Campylobacter from feces during defeathering.
Berrang, M E; Buhr, R J; Cason, J A; Dickens, J A
2001-12-01
Three sets of experiments were conducted to explore the increase in recovery of Campylobacter from broiler carcasses after defeathering. In the first set of experiments, live broilers obtained from a commercial processor were transported to a pilot plant, and breast skin was sampled by a sponge wipe method before and after defeathering. One of 120 broiler breast skin samples was positive for Campylobacter before defeathering, and 95 of 120 were positive after defeathering. In the second set of experiments, Campylobacter-free flocks were identified, subjected to feed withdrawal, and transported to the pilot plant. Carcasses were intracloacally inoculated with Campylobacter (10(7) CFU) just prior to entering the scald tank. Breast skin sponge samples were negative for Campylobacter before carcasses entered the picker (0 of 120 samples). After defeathering, 69 of 120 samples were positive for Campylobacter, with an average of log10 2.7 CFU per sample (approximately 30 cm2). The third set of experiments was conducted using Campylobacter-positive broilers obtained at a commercial processing plant and transported live to the pilot plant. Just prior to scalding, the cloacae were plugged with tampons and sutured shut on half of the carcasses. Plugged carcasses were scalded, and breast skin samples taken before and after defeathering were compared with those collected from control broilers from the same flock. Prior to defeathering, 1 of 120 breast skin sponge samples were positive for the control carcasses, and 0 of 120 were positive for the plugged carcasses. After passing through the picker, 120 of 120 control carcasses had positive breast skin sponge samples, with an average of log10 4.2 CFU per sample (approximately 30 cm2). Only 13 of 120 plugged carcasses had detectable numbers of Campylobacter on the breast skin sponge, with an average of log10 2.5 CFU per sample. These data indicate that an increase in the recovery of Campylobacter after defeathering can be related to the escape of contaminated feces from the cloaca during defeathering.
Kenters, Nikki; Huijskens, Elisabeth G W; de Wit, Sophie C J; van Rosmalen, Joost; Voss, Andreas
2017-08-01
Hospital rooms play an important role in the transmission of several health care-associated pathogens. During the last few years, a number of innovative cleaning-disinfecting products have been brought to market. In this study, commercially available products combining cleaning and disinfection were compared, using 2 different application methods. The aim was to determine which product was most effective in simultaneous cleaning and disinfection of surfaces. Seven cleaning-disinfecting wipes and sprays based on different active ingredients were tested for their efficacy in removal of microbial burden and proteins. Efficacy was tested with known Dutch outbreak strains: vancomycin-resistant enterococci (VRE), Klebsiella pneumoniae OXA-48, or Acinetobacter baumannii. For all bacteria, ready-to-use cleaning-disinfecting products reduced the microbial count with a log 10 reduction >5 with a 5-minute exposure time, with the exception of a spray based on hydrogen peroxide. Omitting the aforementioned hydrogen peroxide spray, there were no significant differences between use of a wipe or spray in bacterial load reduction. Using adenosine triphosphate (ATP) measurements, a significant difference in log 10 relative light units (RLU) reduction between various bacteria (P ≤ .001) was observed. In general, a >5 log 10 reduction of colony forming units (CFU) for tested wipes and sprays was obtained for all tested bacteria strains, with exception of hydrogen peroxide spray and VRE. Although ATP may show a difference between pre- and postcleaning, RLU reduction does not correlate with actual CFU reductions. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
A sampling device with a capped body and detachable handle
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jezek, Gerd-Rainer
1997-12-01
The present invention relates to a device for sampling radioactive waste and more particularly to a device for sampling radioactive waste which prevents contamination of a sampled material and the environment surrounding the sampled material. During vitrification of nuclear wastes, it is necessary to remove contamination from the surfaces of canisters filled with radioactive glass. After removal of contamination, a sampling device is used to test the surface of the canister. The one piece sampling device currently in use creates a potential for spreading contamination during vitrification operations. During operations, the one piece sampling device is transferred into and outmore » of the vitrification cell through a transfer drawer. Inside the cell, a remote control device handles the sampling device to wipe the surface of the canister. A one piece sampling device can be contaminated by the remote control device prior to use. Further, the sample device can also contaminate the transfer drawer producing false readings for radioactive material. The present invention overcomes this problem by enclosing the sampling pad in a cap. The removable handle is reused which reduces the amount of waste material.« less
Arhun, Neslihan; Cehreli, Sevi Burcak
2013-01-01
Reestablishing proximal contacts with composite resins may prove challenging since the applied adhesives may lead to resin coating that produces additional thickness. The aim of this study was to investigate the surface of metal matrix bands after application of adhesive systems and blowing or wiping off the adhesive before polymerization. Seventeen groups of matrix bands were prepared. The remnant particles were characterized by energy dispersive spectrum and scanning electron microscopy. Total etch and two-step self-etch adhesives did not leave any resin residues by wiping and blowing off. All-in-one adhesive revealed resin residues despite wiping off. Prime and Bond NT did not leave any remnant with compomer. Clinicians must be made aware of the consequences of possible adhesive remnants on matrix bands that may lead to a defective definitive restoration. The adhesive resin used for Class II restorations may leave resin coats on metal matrix bands after polymerization, resulting in additional thickness on the metal matrix bands and poor quality of the proximal surface of the definitive restoration when the adhesive system is incorporated in the restoration.
Tamaddonfard, Esmaeal; Hamzeh-Gooshchi, Nasrin
2010-01-01
The present study investigated the effects of subcutaneous (sc) and intracerebroventricular (icv) injections of physostigmine (a cholinesterase inhibitor), atropine (an antagonist of muscarinic cholinergic receptors) and hexamethonium (an antagonist of nicotinic cholinergic receptors) on the acute corneal nociception in rats. Local application of 5 M NaCl solution on the corneal surface of the eye produced a significant nociceptive behavior, characterized by eye wiping. The number of eye wipes was counted during the first 30 s. The sc (0.25, 0.5 and 1 mg/kg) and icv (1.25, 2.5, 5 and 10 μg) injections of physostigmine significantly (p < 0.05) decreased the number of eye wipes. Atropine and hexamethonium at (2 mg/kg, sc and 20 μg, icv) had no effects when used alone, however, atropine, but not hexamethonium prevented the antinociception induced by physostigmine (sc and icv). The results of this study indicate that the central muscarinic, but not nicotinic receptors might be involved in the antinociceptive effect of physostigmine in the acute corneal model of pain in rats.
Terra Firma-Forme Dermatosis in Singaporean Patients: The "Alcohol Wipe" Sign.
Oh, Choon Chiat; Oon, Hazel H; Ng, See Ket; Tee, Shang Ian; Jhingan, Anjali; Chong, Wei-Sheng
2016-01-01
The term terra firma-forme dermatosis arises from the Latin phrase terra firma , meaning dry land (dirt), thus implying dirt-like dermatosis. The authors highlight five cases of patients with terra firma-forme dermatosis presenting to our dermatology center between 2012 and 2013. All patients presented to the dermatologist for persistent reticulated brown patches on the skin. These patients ranged in age from 6 to 22 years. All patients had tried various cleansing soaps and agents but were unable to remove the patches. The condition was cosmetically unacceptable to the patients and parents. Clinically, these patients had reticulated brown patches. Rubbing 70% isopropyl alcohol wipes on the affected areas demonstrated clearance of the brown pigmented patches in all cases. The diagnosis of terra firma-forme dermatosis (TFFD) was confirmed by forceful rubbing with a gauze pad immersed in 70% isopropyl alcohol or ethyl alcohol. Patients should be reassured about the benign nature of TFFD and educated about the cleaning procedure. Recognition of this condition can assist physicians in making a diagnosis and therapy with a simple alcohol wipe, preventing further unnecessary tests for patients.
Biomarkers of mercury exposure in two eastern Ukraine cities
Gibb, H.; Haver, C.; Kozlov, K.; Centeno, J.A.; Jurgenson, V.; Kolker, A.; Conko, K.M.; Landa, E.R.; Xu, H.
2011-01-01
This study evaluates biomarkers of mercury exposure among residents of Horlivka, a city in eastern Ukraine located in an area with geologic and industrial sources of environmental mercury, and residents of Artemivsk, a nearby comparison city outside the mercury-enriched area. Samples of urine, blood, hair, and nails were collected from study participants, and a questionnaire was administered to obtain data on age, gender, occupational history, smoking, alcohol consumption, fish consumption, tattoos, dental amalgams, home heating system, education, source of drinking water, and family employment in mines. Median biomarker mercury concentrations in Artemivsk were 0.26 ??g/g-Cr (urine), 0.92 ??g/L (blood), 0.42 ??g/g (hair), 0.11 ??g/g (toenails), and 0.09 ??g/g (fingernails); median concentrations in Horlivka were 0.15 ??g/g-Cr (urine), 1.01 ??g/L (blood), 0.14 ??g/g (hair), 0.31 ??g/g (toenails), and 0.31 ??g/g (fingernails). Biomarkers of mercury exposure for study participants from Horlivka and Artemivsk are low in comparison with occupationally exposed workers at a mercury recycling facility in Horlivka and in comparison with exposures known to be associated with clinical effects. Blood and urinary mercury did not suggest a higher mercury exposure among Horlivka residents as compared with Artemivsk; however, three individuals living in the immediate vicinity of the mercury mines had elevated blood and urinary mercury, relative to overall results for either city. For a limited number of residents from Horlivka (N = 7) and Artemivsk (N = 4), environmental samples (vacuum cleaner dust, dust wipes, soil) were collected from their residences. Mercury concentrations in vacuum cleaner dust and soil were good predictors of blood and urinary mercury. Copyright ?? 2011 JOEH, LLC.
Surface cleanliness measurement procedure
Schroder, Mark Stewart; Woodmansee, Donald Ernest; Beadie, Douglas Frank
2002-01-01
A procedure and tools for quantifying surface cleanliness are described. Cleanliness of a target surface is quantified by wiping a prescribed area of the surface with a flexible, bright white cloth swatch, preferably mounted on a special tool. The cloth picks up a substantial amount of any particulate surface contamination. The amount of contamination is determined by measuring the reflectivity loss of the cloth before and after wiping on the contaminated system and comparing that loss to a previous calibration with similar contamination. In the alternative, a visual comparison of the contaminated cloth to a contamination key provides an indication of the surface cleanliness.
Tools for measuring surface cleanliness
Schroder, Mark Stewart; Woodmansee, Donald Ernest; Beadie, Douglas Frank
2002-01-01
A procedure and tools for quantifying surface cleanliness are described. Cleanliness of a target surface is quantified by wiping a prescribed area of the surface with a flexible, bright white cloth swatch, preferably mounted on a special tool. The cloth picks up a substantial amount of any particulate surface contamination. The amount of contamination is determined by measuring the reflectivity loss of the cloth before and after wiping on the contaminated system and comparing that loss to a previous calibration with similar contamination. In the alternative, a visual comparison of the contaminated cloth to a contamination key provides an indication of the surface cleanliness.
NASA Technical Reports Server (NTRS)
Keen, Jill M.; DeWeese, Darrell C.; Key, Leigh W.
1997-01-01
At Kennedy Space Center (KSC), Thiokol Corporation provides the engineering to assemble and prepare the Space Shuttle Reusable Solid Rocket Motor (RSRM) for launch. This requires hand cleaning over 86 surfaces including metals, adhesives, rubber and electrical insulations, various painted surfaces and thermal protective materials. Due to the phase-out of certain ozone depleting chemical (ODC) solvents, all RSRM hand wipe operations being performed at KSC using l,l,1-trichloroethane (TCA) were eliminated. This presentation summarizes the approach used and the data gathered in the effort to eliminate TCA from KSC hand wipe operations.
2010-02-01
APPENDIXES A. COUPON STOCK MATERIAL AND PREPARATION 141 B. CONTROL CHARTS 143 C. ANALYTICAL INSTRUMENTATION PARAMETERS 171 D. COUPON CHAIN-OF...were cut from stock material. Vitron® is a registered trademark of Vitron Manufacturing, Phoenix, AZ Kapton® is a register trademark of E.I. DuPont... Eft Wipe Wipe Ext. Eff. 15M 15M 15M 15M 0 300 600 0 4/4 5/5 5/5 4/4 3,740,999 ± 2,377,014 135876 ±51295 50896 ± 38227 120004 ±8130
Matt, Georg E; Quintana, Penelope J E; Hoh, Eunha; Zakarian, Joy M; Chowdhury, Zohir; Hovell, Melbourne F; Jacob, Peyton; Watanabe, Kayo; Theweny, Teaba S; Flores, Victoria; Nguyen, Anh; Dhaliwal, Narinder; Hayward, Gary
2018-02-08
Secondhand smoke (SHS) in US casinos is common, but little is known about the residue of tobacco smoke pollutants left behind in dust and on surfaces, commonly referred to as thirdhand smoke (THS). We examined SHS and THS pollution and exposure before and during a casino smoking ban and after smoking resumed. A casino was visited nine times over a 15-month period to collect dust, surface and air samples in eight locations. Finger wipe and urine samples were collected from non-smoking confederates before and after a 4-hour casino visit. Samples were analysed for markers of SHS and THS pollution and exposure. Exceptionally high levels of THS were found in dust and on surfaces. Although the smoking ban led to immediate improvements in air quality, surface nicotine levels were unchanged and remained very high for the first month of the smoking ban. Surface nicotine decreased by 90% after 1 month (P<0.01), but nicotine and tobacco-specific nitrosamines in dust decreased more slowly, declining by 90% only after 3 months (P<0.01). Exposure was significantly reduced after the ban, but the benefits of the ban were reversed after smoking resumed. Long-term smoking in a casino creates deep THS reservoirs that persist for months after a smoking ban. A complete smoking ban immediately improves air quality and significantly reduces exposure to SHS and THS. However, THS reservoirs contribute to continued low-level exposure to toxicants. To accelerate the effect of smoking bans, remediation efforts should address specific THS reservoirs, which may require intensive cleaning as well as replacement of carpets, furniture and building materials. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Lead exposure in Mexican radiator repair workers.
Dykeman, Ronald; Aguilar-Madrid, Guadalupe; Smith, Tom; Juárez-Pérez, Cuauhtemoc Arturo; Piacitelli, Gregory M; Hu, Howard; Hernandez-Avila, Mauricio
2002-03-01
Lead exposure was investigated among 73 Mexican radiator repair workers (RRWs), 12 members of their family (4 children and 8 wives), and 36 working controls. RRWs were employed at 4 radiator repair shops in Mexico City and 27 shops in Cuernavaca and surrounding areas. Exposure was assessed directly through the use of personal air sampling and hand wipe samples. In addition, industrial hygiene inspections were performed and detailed questionnaires were administered. Blood lead levels were measured by graphite furnace atomic absorption spectroscopy (AAS). The mean (SD) values for blood lead of the RRWs, 35.5 (13.5) microg/dl, was significantly greater than the same values for the working controls, 13.6 (8.7) microg/dl; P < 001. After excluding a single outlier (247 microg/m(3)), air lead levels ranged from 0 to 99 microg/m(3) with a mean (SD) value of 19 (23) microg/m(3) (median = 7.9 microg/m(3)). In a final multivariate regression model of elevated blood lead levels, the strongest predictors were smoking (vs. non-smoking), the number of radiators repaired per day on average, and the use (vs. non-use) of a uniform while at work, which were associated with blood lead elevations of 11.4 microg/dl, 1.95 microg/dl/radiator/day, and 16.4 microg/dl, respectively (all P <.05). Uniform use was probably a risk factor because they were not laundered regularly and consequently served as reservoir of contamination on which RRWs frequently wiped their hands. Lead exposure is a significant problem of radiator repair work, a small industry that is abundant in Mexico and other developing countries. Copyright 2002 Wiley-Liss, Inc.
NASA Astrophysics Data System (ADS)
Farahi, Maria; Rabbani, Hossein; Talebi, Ardeshir; Sarrafzadeh, Omid; Ensafi, Shahab
2015-12-01
Visceral Leishmaniasis is a parasitic disease that affects liver, spleen and bone marrow. According to World Health Organization report, definitive diagnosis is possible just by direct observation of the Leishman body in the microscopic image taken from bone marrow samples. We utilize morphological and CV level set method to segment Leishman bodies in digital color microscopic images captured from bone marrow samples. Linear contrast stretching method is used for image enhancement and morphological method is applied to determine the parasite regions and wipe up unwanted objects. Modified global and local CV level set methods are proposed for segmentation and a shape based stopping factor is used to hasten the algorithm. Manual segmentation is considered as ground truth to evaluate the proposed method. This method is tested on 28 samples and achieved 10.90% mean of segmentation error for global model and 9.76% for local model.
Assessment of arsenic exposures and controls in gallium arsenide production.
Sheehy, J W; Jones, J H
1993-02-01
The electronics industry is expanding the use of gallium arsenide in the production of optoelectronic devices and integrated circuits. Workers in the electronics industry using gallium arsenide are exposed to hazardous substances such as arsenic, arsine, and various acids. Arsenic requires stringent controls to minimize exposures (the current OSHA PEL for arsenic is 10 micrograms/m3 and the NIOSH REL is 2 micrograms/m3 ceiling). Inorganic arsenic is strongly implicated in respiratory tract and skin cancer. For these reasons, NIOSH researchers conducted a study of control systems for facilities using gallium arsenide. Seven walk-through surveys were performed to identify locations for detailed study which appeared to have effective controls; three facilities were chosen for in-depth evaluation. The controls were evaluated by industrial hygiene sampling. Including personal breathing zone and area air sampling for arsenic and arsine; wipe samples for arsenic also were collected. Work practices and the use of personal protective equipment were documented. This paper reports on the controls and the arsenic exposure results from the evaluation of the following gallium arsenide processes: Liquid Encapsulated Czochralski (LEC) and Horizontal Bridgeman (HB) crystal growing, LEC cleaning operations, ingot grinding/wafer sawing, and epitaxy. Results at one plant showed that in all processes except epitaxy, average arsenic exposures were at or above the OSHA action level of 5 micrograms/m3. While cleaning the LEC crystal pullers, the average potential arsenic exposure of the cleaning operators was 100 times the OSHA PEL. At the other two plants, personal exposures for arsenic were well controlled in LEC, LEC cleaning, grinding/sawing, and epitaxy operations.
2003-09-03
KENNEDY SPACE CENTER, FLA. - A KSC employee wipes down some of the hoses of the ground support equipment in the Orbiter Processing Facility (OPF) where Space Shuttle Atlantis is being processed for flight. Preparations are under way for the next launch of Atlantis on mission STS-114, a utilization and logistics flight to the International Space Station.
The use of twin screw extruders for feeding coal against pressures of up to 1500 PSI
NASA Technical Reports Server (NTRS)
Wiedmann, W.; Mack, W. A.
1977-01-01
Recent tests with a twin-screw, co-rotating extruder which was successfully used to convey and feed coal against pressures of up to 1500 psi are described. Intermeshing and self-wiping, co-rotating twin-screws give greatly improved conveying and pressure built-up capabilities and avoid hangup and eventual decomposition of coal particles in the screw flights. The conveying action of intermeshing, self-wiping, co-rotating extruder systems approaches that of a positive displacement pump. With this feature, it is possible to maintain very accurate control over all aspects of product conveyance in the extruder, i.e., intake, conveyance and pressure buildup.
Benefits of automated surface decontamination of a radioiodine ward.
Westcott, Eliza; Broadhurst, Alicia; Crossley, Steven; Lee, Lloyd; Phan, Xuyen; Scharli, Rainer; Xu, Yan
2012-02-01
A floor-washing robot has been acquired to assist physicists with decontamination of radioiodine therapy ward rooms after discharge of the patient at Sir Charles Gairdner Hospital. The effectiveness of the robot in decontaminating the ward has been evaluated. A controlled experiment was performed by deliberately contaminating a polyvinyl chloride flooring offcut with 131I followed by automated decontamination with the robot. The extent of fixed and removable contamination was assessed before and after decontamination by two methods: (1) direct Geiger-Mueller counting and (2) beta-counting wipe tests. Surface contamination was also assessed in situ on the ward by Geiger-Mueller counting and wipe testing. Contamination maps confirmed that contamination was removed rather than spread around by the robot. Wipe testing revealed that the robot was successful in clearing approximately 60-80% of removable contamination. The robotic floor-washing device was considered suitable to provide effective automated decontamination of the radioiodine ward. In addition, the robot affords other benefits: the time spent by the physicists decontaminating the room is greatly reduced offering financial and occupational safety and health benefits. The robot has also found utility in other decontamination applications in the healthcare environment.
Perceiving non-native speech: Word segmentation
NASA Astrophysics Data System (ADS)
Mondini, Michèle; Miller, Joanne L.
2004-05-01
One important source of information listeners use to segment speech into discrete words is allophonic variation at word junctures. Previous research has shown that non-native speakers impose their native-language phonetic norms on their second language; as a consequence, non-native speech may (in some cases) exhibit altered patterns of allophonic variation at word junctures. We investigated the perceptual consequences of this for word segmentation by presenting native-English listeners with English word pairs produced either by six native-English speakers or six highly fluent, native-French speakers of English. The target word pairs had contrastive word juncture involving voiceless stop consonants (e.g., why pink/wipe ink; gray ties/great eyes; we cash/weak ash). The task was to identify randomized instances of each individual target word pair (as well as control pairs) by selecting one of four possible choices (e.g., why pink, wipe ink, why ink, wipe pink). Overall, listeners were more accurate in identifying target word pairs produced by the native-English speakers than by the non-native English speakers. These findings suggest that one contribution to the processing cost associated with listening to non-native speech may be the presence of altered allophonic information important for word segmentation. [Work supported by NIH/NIDCD.
Clausen, Per Axel; Spaan, Suzanne; Brouwer, Derk H; Marquart, Hans; le Feber, Maaike; Engel, Roel; Geerts, Lieve; Jensen, Keld Alstrup; Kofoed-Sørensen, Vivi; Hansen, Brian; De Brouwere, Katleen
2016-01-01
The aim of this work was to identify the key mechanisms governing transport of organic chemical substances from consumer articles to cotton wipes. The results were used to establish a mechanistic model to improve assessment of dermal contact exposure. Four types of PVC flooring, 10 types of textiles and one type of inkjet printed paper were used to establish the mechanisms and model. Kinetic extraction studies in methanol demonstrated existence of matrix diffusion and indicated the presence of a substance surface layer on some articles. Consequently, the proposed substance transfer model considers mechanical transport from a surface film and matrix diffusion in an article with a known initial total substance concentration. The estimated chemical substance transfer values to cotton wipes were comparable to the literature data (relative transfer ∼ 2%), whereas relative transfer efficiencies from spiked substrates were high (∼ 50%). For consumer articles, high correlation (r(2)=0.92) was observed between predicted and measured transfer efficiencies, but concentrations were overpredicted by a factor of 10. Adjusting the relative transfer from about 50% used in the model to about 2.5% removed overprediction. Further studies are required to confirm the model for generic use.
2014-01-01
Residential exposure can dominate total exposure for commercial chemicals of health concern; however, despite the importance of consumer exposures, methods for estimating household exposures remain limited. We collected house dust and indoor air samples in 49 California homes and analyzed for 76 semivolatile organic compounds (SVOCs)—phthalates, polybrominated diphenyl ethers (PBDEs), polychlorinated biphenyls (PCBs), polycyclic aromatic hydrocarbons (PAHs), and pesticides. Sixty chemicals were detected in either dust or air and here we report 58 SVOCs detected in dust for the first time. In dust, phthalates (bis(2-ethylhexyl) phthalate, benzyl butyl phthalate, di-n-butyl phthalate) and flame retardants (PBDE 99, PBDE 47) were detected at the highest concentrations relative to other chemicals at the 95th percentile, while phthalates were highest at the median. Because SVOCs are found in both gas and condensed phases and redistribute from their original source over time, partitioning models can clarify their fate indoors. We use empirical data to validate air-dust partitioning models and use these results, combined with experience in SVOC exposure assessment, to recommend residential exposure measurement strategies. We can predict dust concentrations reasonably well from measured air concentrations (R2 = 0.80). Partitioning models and knowledge of chemical Koa elucidate exposure pathways and suggest priorities for chemical regulation. These findings also inform study design by allowing researchers to select sampling approaches optimized for their chemicals of interest and study goals. While surface wipes are commonly used in epidemiology studies because of ease of implementation, passive air sampling may be more standardized between homes and also relatively simple to deploy. Validation of passive air sampling methods for SVOCs is a priority. PMID:25488487
Stout, D M; Leidy, R B
2000-07-01
Methods have been developed to monitor the translocation of microencapsulated cyfluthrin following perimeter applications to residential dwellings. A pilot study was implemented to determine both the potential for application spray to drift away from dwellings and the intrusion of residues into homes following perimeter treatments. Residential monitoring included measuring spray drift using cellulose filter paper and the collection of soil samples from within the spray zone. In addition, interior air was monitored using fiberglass filter paper as a sorbent medium and cotton ball swabs were used to collect surface wipes. Fortification of matrixes resulted in recoveries of > 90%. Spray drift was highest at the point of application and declined to low but measurable levels 9.1 m from the foundations of dwellings. Soil residues declined to low, but measurable levels by 45 days post-application. No cyfluthrin was measured from indoor air; however, some interior surfaces had detectable levels of cyfluthrin until three days post-application. Findings indicate that spray drift resulting from perimeter applications might contaminate non-target surfaces outside the spray zone. Soil borne residues may serve as persistent sources for human exposure and potentially intrude into dwellings through the activities of occupants and pets. Residues do not appreciably translocate through air and consequently inhalation is not a likely route for human exposure. Surface residues detected indoors suggest that the physical movement of residues from the exterior to the interior might be a viable route of movement of residues following this type of application.
Ghantoji, Shashank S.; Stibich, Mark; Stachowiak, Julie; Cantu, Sherry; Adachi, Javier A.; Raad, Issam I.
2015-01-01
The standard for Clostridium difficile surface decontamination is bleach solution at a concentration of 10 % of sodium hypochlorite. Pulsed xenon UV light (PX-UV) is a means of quickly producing germicidal UV that has been shown to be effective in reducing environmental contamination by C. difficile spores. The purpose of this study was to investigate whether PX-UV was equivalent to bleach for decontamination of surfaces in C. difficile infection isolation rooms. High-touch surfaces in rooms previously occupied by C. difficile infected patients were sampled after discharge but before and after cleaning using either bleach or non-bleach cleaning followed by 15 min of PX-UV treatment. A total of 298 samples were collected by using a moistened wipe specifically designed for the removal of spores. Prior to disinfection, the mean contamination level was 2.39 c.f.u. for bleach rooms and 22.97 for UV rooms. After disinfection, the mean level of contamination for bleach was 0.71 c.f.u. (P = 0.1380), and 1.19 c.f.u. (P = 0.0017) for PX-UV disinfected rooms. The difference in final contamination levels between the two cleaning protocols was not significantly different (P = 0.9838). PX-UV disinfection appears to be at least equivalent to bleach in the ability to decrease environmental contamination with C. difficile spores. Larger studies are needed to validate this conclusion. PMID:25627208
Detection of indoor biological hazards using the man-portable laser induced breakdown spectrometer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Munson, Chase A.; Gottfried, Jennifer L.; Snyder, Emily Gibb
2008-11-01
The performance of a man-portable laser induced breakdown spectrometer was evaluated for the detection of biological powders on indoor office surfaces and wipe materials. Identification of pure unknown powders was performed by comparing against a library of spectra containing biological agent surrogates and confusant materials, such as dusts, diesel soot, natural and artificial sweeteners, and drink powders, using linear correlation analysis. Simple models constructed using a second technique, partial least squares discriminant analysis, successfully identified Bacillus subtilis (BG) spores on wipe materials and office surfaces. Furthermore, these models were able to identify BG on materials not used in the trainingmore » of the model.« less
NASA Astrophysics Data System (ADS)
Pearle, Philip
1982-03-01
In the problem of the gambler's ruin, a classic problem in probability theory, a number of gamblers play against each other until all but one of them is “wiped out.” It is shown that this problem is identical to a previously presented formulation of the reduction of the state vector, so that the state vectors in a linear superposition may be regarded as “playing” against each other until all but one of them is “wiped out.” This is a useful part of the description of an objectively real universe represented by a state vector that is a superposition of macroscopically distinguishable states dynamically created by the Hamiltonian and destroyed by the reduction mechanism.
Radio Science Measurements with Suppressed Carrier
NASA Technical Reports Server (NTRS)
Asmar, Sami; Divsalar, Dariush; Oudrhiri, Kamal
2013-01-01
Radio Science started when it became apparent with early Solar missions that occultations by planetary atmospheres would affect the quality of radio communications. Since then the atmospheric properties and other aspects of planetary science, solar science, and fundamental physics were studied by scientists. Radio Science data was always extracted from a received pure residual carrier (without data modulation). For some missions, it is very desirable to obtain Radio Science data from a suppressed carrier modulation. In this paper we propose a method to extract Radio Science data when a coded suppressed carrier modulation is used in deep space communications. Type of modulation can be BPSK, QPSK, OQPSK, MPSK or even GMSK. However we concentrate mostly on BPSK modulation. The proposed method for suppressed carrier simply tries to wipe out data that acts as an interference for Radio Science measurements. In order to measure the estimation errors in amplitude and phase of the Radio Science data we use Cramer-Rao bound (CRB). The CRB for the suppressed carrier modulation with non-ideal data wiping is then compared with residual carrier modulation under the same noise condition. The method of derivation of CRB for non-ideal data wiping is an innovative method that presented here. Some numerical results are provided for coded system.
Matar, Hazem; Guerreiro, Antonio; Piletsky, Sergey A; Price, Shirley C; Chilcott, Robert P
2015-08-13
Rapid decontamination is vital to alleviate adverse health effects following dermal exposure to hazardous materials. There is an abundance of materials and products which can be utilised to remove hazardous materials from the skin. In this study, a total of 15 products were evaluated, 10 of which were commercial or military products and five were novel (molecular imprinted) polymers. The efficacies of these products were evaluated against a 10 µl droplet of 14 C-methyl salicylate applied to the surface of porcine skin mounted on static diffusion cells. The current UK military decontaminant (Fuller's earth) performed well, retaining 83% of the dose over 24 h and served as a benchmark to compare with the other test products. The five most effective test products were Fuller's earth (the current UK military decontaminant), Fast-Act® and three novel polymers [based on itaconic acid, 2-trifluoromethylacrylic acid and N,N-methylenebis(acrylamide)]. Five products (medical moist-free wipes, 5% FloraFree™ solution, normal baby wipes, baby wipes for sensitive skin and Diphotérine™) enhanced the dermal absorption of 14 C-methyl salicylate. Further work is required to establish the performance of the most effective products identified in this study against chemical warfare agents.
Matar, Hazem; Guerreiro, Antonio; Piletsky, Sergey A; Price, Shirley C; Chilcott, Robert P
2016-01-01
Rapid decontamination is vital to alleviate adverse health effects following dermal exposure to hazardous materials. There is an abundance of materials and products which can be utilised to remove hazardous materials from the skin. In this study, a total of 15 products were evaluated, 10 of which were commercial or military products and five were novel (molecular imprinted) polymers. The efficacies of these products were evaluated against a 10 µl droplet of (14)C-methyl salicylate applied to the surface of porcine skin mounted on static diffusion cells. The current UK military decontaminant (Fuller's earth) performed well, retaining 83% of the dose over 24 h and served as a benchmark to compare with the other test products. The five most effective test products were Fuller's earth (the current UK military decontaminant), Fast-Act® and three novel polymers [based on itaconic acid, 2-trifluoromethylacrylic acid and N,N-methylenebis(acrylamide)]. Five products (medical moist-free wipes, 5% FloraFree™ solution, normal baby wipes, baby wipes for sensitive skin and Diphotérine™) enhanced the dermal absorption of (14)C-methyl salicylate. Further work is required to establish the performance of the most effective products identified in this study against chemical warfare agents.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Taylor, Mark Patrick, E-mail: mark.taylor@mq.edu.au; Mould, Simon Anthony; Kristensen, Louise Jane
Although blood lead values in children are predominantly falling globally, there are locations where lead exposure remains a persistent problem. One such location is Broken Hill, Australia, where the percentage of blood lead values >10 μg/dL in children aged 1–4 years has risen from 12.6% (2010), to 13% (2011) to 21% (2012). The purpose of this study was to determine the extent of metal contamination in places accessible to children. This study examines contemporary exposure risks from arsenic, cadmium, lead, silver and zinc in surface soil and dust, and in pre- and post-play hand wipes at six playgrounds across Brokenmore » Hill over a 5-day period in September 2013. Soil lead (mean 2,450 mg/kg) and zinc (mean 3,710 mg/kg) were the most elevated metals in playgrounds. Surface dust lead concentrations were consistently elevated (mean 27,500 μg/m{sup 2}) with the highest lead in surface dust (59,900 μg/m{sup 2}) and post-play hand wipes (60,900 μg/m{sup 2}) recorded close to existing mining operations. Surface and post-play hand wipe dust values exceeded national guidelines for lead and international benchmarks for arsenic, cadmium and lead. Lead isotopic compositions ({sup 206}Pb/{sup 207}Pb, {sup 208}Pb/{sup 207}Pb) of surface dust wipes from the playgrounds revealed the source of lead contamination to be indistinct from the local Broken Hill ore body. The data suggest frequent, cumulative and ongoing mine-derived dust metal contamination poses a serious risk of harm to children. - Highlights: 1.Playground soils and surface dust in a mining town have high metal concentrations. 2.Elevated levels of As, Cd, Pb and Zn dust are found on playground users′ hands. 3.Pb isotope analysis shows that the source of playground dust is ore body Pb. 4.Surface mine operations must be contained to reduce childhood lead exposure risks. 5.Mine environmental licences need to set trigger values for As, Cd, Pb and Zn dust.« less
Laboratory evaluation of polychlorinated biphenyls ...
Effectiveness and limitations of the encapsulation method for reducing polychlorinated biphenyls (PCBs) concentrations in indoor air and contaminated surface have been evaluated in the laboratory study. Ten coating materials such as epoxy and polyurethane coatings, latex paint, and petroleum-based paint were tested in small environmental chambers to rank the encapsulants by their resistance to PCB sorption and estimate the key parameters required by a barrier model. Wipe samples were collected from PCB contaminated surface encapsulated with the coating materials to rank the encapsulants by their resistance to PCB migration from the source. A barrier model was used to calculate the PCB concentrations in the sources and the encapsulant layers, and at the exposed surfaces of the encapsulant and in the room air at different times. The performance of the encapsulants was ranked by those concentrations and PCB percent reductions. Overall, the three epoxy coatings performed better than the other coatings. Both the experimental results and the mathematical modeling showed that selecting proper encapsulants can effectively reduce the PCB concentrations at the exposed surfaces. The encapsulation method is most effective for contaminated surfaces that contain low levels of PCBs. This study answers some of these questions by using a combination of laboratory testing and mathematical modeling. The results should be useful to mitigation engineers, building owners and managers
Variation in feminine hygiene practices as a function of age.
Czerwinski, B S
2000-01-01
To examine variation in feminine hygiene practices as a function of increasing age. A nonexperimental, descriptive research design with study sample stratified by age. Women over 18 years of age. Of 713 women who completed and returned the feminine hygiene practices questionnaire, 180 were younger than 41 years, 171 were 41-48 years, 184 were 49-57 years, and 178 were 58 years or older. All participants were members of a California professional home economics organization. A 40-item feminine hygiene practices questionnaire dealing with body cleansing practices, feminine products usage, and both general and specific menses collection and protection practices. Significant age-related differences were found in several areas of body cleansing and feminine products usage, including sponge bathing and use of feminine and deodorant spray, wet wipes, and panty liners. In all age groups, 20-30% of women reported douching, even in the face of continued reports of the dangers in this practice. In addition, reduced numbers of women (n = 245) in all age groups reported washing hands before using tampons or pads, although more (n = 314) reported washing their hands afterward. Continuing education about proper feminine hygiene practices, especially regarding douching and handwashing before and after genitourinary contact, will be important across all age groups.
Egert, Markus; Späth, Kerstin; Weik, Karoline; Kunzelmann, Heike; Horn, Christian; Kohl, Matthias; Blessing, Frithjof
2015-03-01
Smartphone touchscreens are known as pathogen carriers in clinical environments. However, despite a rapidly growing number of smartphone users worldwide, little is known about bacterial contamination of smartphone touchscreens in non-clinical settings. Such data are needed to better understand the hygienic relevance of these increasingly popular items. Here, 60 touchscreens of smartphones provided by randomly chosen students of a German university were sampled by directly touching them with contact agar plates. The average bacterial load of uncleaned touchscreens was 1.37 ± 0.33 CFU/cm(2). Touchscreens wiped with commercially available microfiber cloths or alcohol-impregnated lens wipes contained significantly less bacteria than uncleaned touchscreens, i.e., 0.22 ± 0.10 CFU/cm(2) and 0.06 ± 0.02 CFU/cm(2), respectively. Bacteria isolated from cleaned and uncleaned touchscreens were identified by means of MALDI Biotyping. Out of 111 bacterial isolates, 56 isolates (50 %) were identified to genus level and 27 (24 %) to species level. The vast majority of the identified bacteria were typical human skin, mouth, lung, and intestinal commensals, mostly affiliated with the genera Staphylococcus and Micrococcus. Five out of 10 identified species were opportunistic pathogens. In conclusion, the touchscreens investigated here showed low bacterial loads and a species spectrum that is typical for frequently touched surfaces in domestic and public environments, the general health risk of which is still under debate.
Bush, Derek; Goniewicz, Maciej L
2015-06-01
Nicotine deposited on the surfaces has been shown to react with airborne chemicals leading to formation of carcinogens and contributing to thirdhand exposure. While prior studies revealed nicotine residues in tobacco smokers' homes, none have examined the nicotine residue in electronic cigarette (e-cigarette) users' homes. We measured nicotine on the surfaces in households of 8 e-cigarette users, 6 cigarette smokers, and 8 non-users of nicotine-containing products in Western New York, USA. Three surface wipe samples were taken from the floor, wall and window. Nicotine was extracted from the wipes and analyzed using gas chromatography. Half of the e-cigarette users' homes had detectable levels of nicotine on surfaces whereas nicotine was found in all of the tobacco cigarette smokers' homes. Trace amounts of nicotine were also detected in half of the homes of non-users of nicotine-containing products. Nicotine levels in e-cigarette users homes was significantly lower than that found in cigarette smokers homes (average concentration 7.7±17.2 vs. 1303±2676 μg/m2; p<0.05). There was no significant difference in the amount of nicotine in homes of e-cigarette users and non-users (p>0.05). Nicotine is a common contaminant found on indoor surfaces. Using e-cigarettes indoors leads to significantly less thirdhand exposure to nicotine compared to smoking tobacco cigarettes. Copyright © 2015 Elsevier B.V. All rights reserved.
Solvent Replacement for Hydrochlorofluorocarbon-225 for Cleaning Oxygen System Components
NASA Technical Reports Server (NTRS)
Mitchell, M. A.; Lowrey, N. M.
2017-01-01
This Technical Memorandum is the result of a 2-year project funded by the Defense Logistics Agency-Aviation, Hazardous Minimization and Green Products Branch, to identify and test two candidate solvents to replace hydrochlorofluorocarbon-225 (HCFC-225) for cleaning oxygen systems. The solvents were also compared to a second solvent composed predominantly of perfluorobutyl iodide (PFBI), which had received limited approval by the United States Air Force (USAF) for hand wipe cleaning of components for aviators’ breathing oxygen systems. The tests performed for this study were based on those reported in AFRL-ML-WP-TR-2003-4040, “The Wipe Solvent Program,” the test program used to qualify Ikon® Solvent P for USAF applications.The study was completed in August 2014, prior to the completion of a more extensive study funded by the NASA Rocket Propulsion Test (RPT) program. The results of the RPT project are reported in NASA/TP-2015-18207, “Replacement of Hydrochlorofluorocarbon–225 Solvent for Cleaning and Verification Sampling of NASA Propulsion Oxygen Systems Hardware, Ground Support Equipment, and Associated Test Systems.” The test methods used in this study for nonvolatile residue (NVR) background, materials compatibility, and cleaning effectiveness were different than those used for the RPT project; a smaller set of materials and contaminants were tested. The tests for this study were complementary to and provided supplementary information for the down-selection process during the course of the test program reported in NASA/TP-2015-218207.
Gulson, Brian; Taylor, Alan; Stifelman, Marc
2018-02-01
The US Environmental Protection Agency (EPA) Integrated Exposure Uptake Biokinetic (IEUBK) model has been widely used to predict blood lead (PbB) levels in children especially around industrial sites. Exposure variables have strongly focussed on the major contribution of lead (Pb) in soil and interior dust to total intake and, in many studies, site-specific data for air, water, diet and measured PbB were not available. We have applied the IEUBK model to a comprehensive data set, including measured PbB, for 108 children monitored over a 5-year period in Sydney, New South Wales, Australia. To use this data set, we have substituted available data (with or without modification) for standard inputs as needed. For example, as an alternative measure for soil Pb concentration (μg/g), we have substituted exterior dust sweepings Pb concentration (μg/g). As alternative measures for interior dust Pb concentration (μg/g) we have used 1) 30-day cumulative petri dish deposition data (PDD) (as µg Pb/m 2 /30days), or 2) hand wipe data (as μg Pb/hand). For comparison, simulations were also undertaken with estimates of dust Pb concentration derived from a prior regression of dust Pb concentration (μg/g) on dust Pb loading (μg/ft 2 ) as concentration is the unit specified for the Model. Simulations for each subject using observed data aggregated over the 5-year interval of the study, the most usual application of the IEUBK model, showed using Wilcoxon tests that there was a significant difference between the observed values and the values predicted by the Model containing soil with hand wipes (p < 0.001), and soil and PDD (p = 0.026) but not those for the other two sets of predictors, based on sweepings and PDD or sweepings and wipes. Overall, simulations of the Model using alternative exposure measures of petri dish dust (and possibly hand wipes) instead of vacuum cleaner dust and dust sweepings instead of soil provide predicted PbB which are generally consistent with each other and observed values. The predicted geometric mean PbBs were 2.17 ( ± 1.24) μg/dL for soil with PDD, 1.95 ( ± 1.17) μg/dL for soil with hand wipes, 2.36 ( ± 1.75) μg/dL for sweepings with PDD, and 2.15 ( ± 1.69) for sweepings with hand wipes. These results are in good agreement with the observed geometric mean PbB of 2.46 ( ± 0.99) μg/dL. In contrast to all other IEUBK model studies to our knowledge, we have stratified the data over the age ranges from 1 to 5 years. The median of the predicted values was lower than that for the observed values for every combination of age and set of measures; in some cases, the difference was statistically significant. The differences between observed and predicted PbB tended to be greatest for the soil plus wipes measure and for the oldest age group. Use of 'default dust' values calculated from the site-specific soil values, a common application of the IEUBK model, results in predicted PbB about 22% (range 0 to 52%) higher than those from soil with PDD data sets. Geometric mean contributions estimated from the Model to total Pb intake for a child aged 1-2 years was 0.09% for air, 42% for diet, 5.3% for water and 42% for soil and dust. Our results indicate that it is feasible to use alternative measures of soil and dust exposure to provide reliable predictions of PbB in urban environments. Copyright © 2017 Elsevier Inc. All rights reserved.
Hon, Chun-Yip; Chua, Prescillia Ps; Danyluk, Quinn; Astrakianakis, George
2014-06-01
Occupational exposure to antineoplastic drugs has been documented to result in various adverse health effects. Despite the implementation of control measures to minimize exposure, detectable levels of drug residual are still found on hospital work surfaces. Cleaning these surfaces is considered as one means to minimize the exposure potential. However, there are no consistent guiding principles related to cleaning of contaminated surfaces resulting in hospitals to adopt varying practices. As such, this pilot study sought to evaluate current cleaning protocols and identify those factors that were most effective in reducing contamination on drug preparation surfaces. Three cleaning variables were examined: (1) type of cleaning agent (CaviCide®, Phenokil II™, bleach and chlorhexidine), (2) application method of cleaning agent (directly onto surface or indirectly onto a wipe) and (3) use of isopropyl alcohol after cleaning agent application. Known concentrations of antineoplastic drugs (either methotrexate or cyclophosphamide) were placed on a stainless steel swatch and then, systematically, each of the three cleaning variables was tested. Surface wipes were collected and quantified using high-performance liquid chromatography-tandem mass spectrometry to determine the percent residual of drug remaining (with 100% being complete elimination of the drug). No one single cleaning agent proved to be effective in completely eliminating all drug contamination. The method of application had minimal effect on the amount of drug residual. In general, application of isopropyl alcohol after the use of cleaning agent further reduced the level of drug contamination although measureable levels of drug were still found in some cases.
Impact of lens case hygiene guidelines on contact lens case contamination.
Wu, Yvonne T; Teng, Yuu Juan; Nicholas, Mary; Harmis, Najat; Zhu, Hua; Willcox, Mark D P; Stapleton, Fiona
2011-10-01
Lens case contamination is a risk factor for microbial keratitis. The effectiveness of manufacturers' lens case cleaning guidelines in limiting microbial contamination has not been evaluated in vivo. This study compared the effectiveness of manufacturers' guidelines and an alternative cleaning regimen. A randomized cross-over clinical trial with two phases (n = 40) was performed. Participants used the lens types of their choice in conjunction with the provided multipurpose solution (containing polyhexamethylene biguanide) for daily wear. In the manufacturers' guideline phase, cases were rinsed with multipurpose solution and air dried. In the alternative regimen phase, cases were rubbed, rinsed with solution, tissue wiped, and air-dried face down. The duration of each phase was 1 month. Lens cases were collected at the end of each phase for microbiological investigation. The levels of microbial contamination were compared, and compliance to both regimens was assessed. The case contamination rate was 82% (32/39) in the manufacturers' guideline group, compared with 72% (28/39) in the alternative regimen group. There were significantly fewer (p = 0.004) colony forming units (CFU) of bacteria from cases used by following the alternative regimen (CFU range of 0 to 10, and median of 12 CFU per well) compared with that of the manufacturer's guidelines (CFU range of 0 to 10, and median of 28 CFU per well). The compliance level between both guidelines was not significantly different (p > 0.05). The alternative guidelines are more effective in eliminating microbial contamination from lens cases than that of the current manufacturer's guideline. Simply incorporating rubbing and tissue-wiping steps in daily case hygiene reduces viable organism contamination.
Cavana, Paola; Peano, Andrea; Petit, Jean-Yanique; Tizzani, Paolo; Perrot, Sébastien; Bensignor, Emmanuel; Guillot, Jacques
2015-01-01
Background Wipes containing chlorhexidine and azole derivates have been recommended for veterinary use. No study has been published about their activity against Malassezia pachydermatis. Hypothesis/Objectives To evaluate the in vivo and in vitro activity of wipes soaked in a chlorhexidine, climbazole and Tris-EDTA solution against Malassezia pachydermatis. Animals Five research colony shar-pei dogs. Methods Wipes were applied once daily onto the left axilla, left groin and perianal area (protocol A), and twice daily on the right axilla, right groin and umbilical region (protocol B) for 3 days. In vivo activity was evaluated by quantifying Malassezia colonies through contact plates on the selected body areas before and after wipe application. The activity of the solution in which the wipes were soaked was assessed in vitro by contact tests following the European Standard UNI EN 1275 guidelines. Results Samples collected after wipe application showed a significant and rapid reduction of Malassezia yeast CFU. No significant difference in the Malassezia reduction was found between protocols A and B. In vitro assay showed 100% activity against Malassezia yeasts after a 15 min contact time with the wipe solution. Conclusions and clinical importance Wipes containing chlorhexidine, climbazole and Tris-EDTA substantially reduced the M. pachydermatis population on the skin of dogs. The results, although this was an uncontrolled study performed on a small number of dogs, suggest that these wipes may be useful for topical therapy of Malassezia dermatitis involving the lips, paws, perianal area and skin folds. Résumé Contexte Des lingettes contenant de la chlorhexidine et des dérivésazolés ont été recommandés en médicine vétérinaire. Aucune étude n'a été publiée sur leur activité contre Malassezia pachydermatis. Hypothèses/Objectifs Evaluer l'activité in vivo et in vitro de lingettes imprégnées d'une solution de chlorhexidine, climbazole et Tris-EDTA contre Malassezia pachydermatis. Sujets Cinq colonies de shar-pei de recherche. Méthodes Les lingettes ont été appliquées une fois par jour au niveau du pli axillaire gauche, le pli inguinal droit et de la zone périanale(protocole A) et deux fois par joursur le pli axillaire droit, le inguinal droit et l'ombilic (protocole B) pendant 3 jours. L'activité in vivo a été évaluée par quantification des colonies de Malassezia par disques de contact sur les zones corporelles choisies avant et après application des lingettes. L'activité de la solution d'imprégnation des lingettes a été testée in vitro par tests de contact suivant les recommandations de l'European Standard UNI EN 1275. Résultats Les échantillons prélevés après application ont montré une diminution importante et rapide des CFU des levures Malassezia. Aucune différence significative dans la diminution des Malassezia n'a été mise en évidence entre les protocoles A et B. Des tests in vitro ont montré 100% d'activité contre les Malassezia après un temps de contact de 15 minutes avec la solution des lingettes. Conclusions et importance Clinique Les lingettes contenant la chlorhexidine, le climbazole et le Tris-EDTA réduisent substantiellement la population de M. pachydermatis sur la peau des chiens. Les résultats, bien qu'il s'agisse d'une étude non contrôlée réalisée sur un faible nombre de chiens, suggère que ces lingettes peuvent être utiles en traitement local de la dermatite à Malassezia des lèvres, des pattes, du périnée et des plis cutanés. Resumen Introducción las gasas que contienen clorhexidina y derivados de azol son recomendadas para uso veterinario. No se ha publicado ningún estudio acerca su actividad contra Malassezia paquidermatis. Hipótesis/Objetivos evaluar la actividad in vivo e in vitro de las gasas con clorhexidina, climbazol y soluciónb Tris-EDTA frente a Malassezia pachydermatis Animales cinco colonias de investigación de perros Sharpei. Métodos las gasas se aplicaron una vez al día en la axila izquierda, zona inguinal izquierda, y zona perianal (protocolo A), y dos veces al día en la axila derecha, zona inguinal derecha, y región umbilical (protocolo B) durante tres días. La actividad in vivo se evaluó mediante cuantificación de las colonias de Malassezia en placas de contacto de zonas seleccionadas del cuerpo antes y después de la aplicación de las gasas. La actividad de la solución en las que las gasas se empaparon se evaluó in vitro mediante pruebas de contacto siguiendo los estándares europeos UNI EN 1275. Resultados las muestras recogidas tras la aplicación de las gasas mostraron una reacción rápida y significativa de las colonias de Malassezia. No hubo significativas en la reducción de Malassezia en los dos protocolos. El ensayo in vitro demostró una actividad del 100% frente a Malassezia tras 15 minutos de contacto con la solución de las gasas. Conclusiones e importancia clínica las gasas que contienen clorhexidina, climbazol y Tris-EDTA reducen sustancialmente la población de Malassezia paquidermatis en la piel de perros. Aunque este era un estudio no controlado y desarrollado en un pequeño número de perros, los resultados sugieren que estas gasas pueden ser útiles para la terapia tópica de dermatitis producida por Malassezia en zonas de los labios, almohadillas plantares, y zonas perianales y pliegues de la piel. Zusammenfassung Hintergrund Feuchttücher, die Chlorhexidinund Azolderivate beinhalten, werden für den veterinärmedizinischen Gebrauch empfohlen. Es gibt keine Studie über ihre Wirkung im Einsatz gegen Malasseziapachydermatis. Hypothese/Ziele Eine Evaluierung der in vivo und der in vitro Aktivität dieser Feuchttücher in einer Chlorhexidin, Climbazol und Tris-EDTA Lösung gegen Malasseziapachydermatis. Tiere Fünf Shar-Peis aus einer Versuchstierkolonie. Methoden Die Feuchttücher wurden einmal täglich in der linken Achsel, in der linken Inguinalgegend und perianal (Protokol A) angewendet, und zweimal täglich in der rechten Achsel, in der rechten Inguinalgegend und umbilikal (Protokol B); beide Protokolle wurden 3 Tage lang durchgeführt. Die in vivo Aktivität wurde durch die Quantifizierung von Malassezienkolonien durch Kontaktplatten an den ausgewählten Körperstellen vor und nach Verwendung der Feuchttücher beurteilt. Die Aktivität der Lösung, in der die Feuchttücher getaucht waren, wurde in vitro mittels Kontakttest, den European Standard UNI EN 1275 Richtlinienfolgend, beurteilt. Ergebnisse Die Proben, die nach Anwendung der Feuchttücher genommen wurden, zeigten eine signifikante und rasche Abnahme der Malassezienhefen CFU. Zwischen den Protokollen A und B wurden keine signifikanten Unterschiede bei der Reduktion der Malassezien gefunden. Der in vitro Test zeigte nach einer 15 minütigen Kontaktzeit mit der Feuchtlösung eine 100%ige Wirkung gegen Malassezien. Schlussfolgerungen und klinische Bedeutung Feuchttücher, die Chlorhexidin, Climbazol und Tris-EDTA enthalten, reduzierten die M. pachydermatisPopulation auf der Haut der Hunde signifikant. Obwohl es sich um eine unkontrollierte Studie handelte, die an einer kleinen Zahl von Hunden durchgeführt wurde, weisen die Ergebnisse darauf hin, dass diese Feuchttücher für eine topische Behandlung der Malasseziendermatitis der Lippen, der Pfoten, der Perianalgegend und der Hautfaltennützlich sein könnten. PMID:26083147
Planetary Protection Plan for an Antibody based instrument proposed for Mars2020
NASA Astrophysics Data System (ADS)
Smith, Heather; Parro, Víctor
The Signs Of Life Detector (SOLID) instrument is a high TRL level instrument proposed for the Mars 2020 instrument suite. In this presentation we describe the planetary protection instrument plan as if the instrument is classified as a life detection instrument compliant with Category IV(b) planetary protection mission requirements, NASA, ESA, and COSPAR policy. SOLID uses antibodies as a method for detecting organic and biomolecular components in soils. Due to the sensitive detection method, the scientific integrity of the instrument exceeds the planetary protection requirements. The instrument will be assembled and integrated in an ISO level 8 cleanroom or better (ISO 4 for the sample read out and fluidics components). Microbial reduction methods and assays employed are as follows: Wipe the outside and inside of the instrument with a mixture of isopropyl alcohol (70%) and water. Cell cultures will be the standard assay to determine enumeration of “viable” spores and other rapid assays such as LAL and ATP bioluminescence as secondary assays to verify the interior of the instrument is microbe free. SOLID’s design factors for contamination control include the following features: SOLID has the capability to heat the catchment tray to pyrolyze any Earth hitchhikers. There will also be an “air gap” of cm maintained between the sample acquisition device and the funnel inlet. This will prevent forward contamination of the sample collection device and reverse contamination of the detection unit. To mitigate false positives, SOLID will include anti-bodies for potential contaminants from organisms most commonly found in clean rooms. If selected for the Mars 2020 Rover, SOLID would be the first life detection instrument based on biomolecules sent by NASA, as such the planetary protection plan will set a precedence for future life detection instruments carrying biomolecules to other planetary bodies.
A comprehensive review of arsenic levels in the semiconductor manufacturing industry.
Park, Donguk; Yang, Haengsun; Jeong, Jeeyeon; Ha, Kwonchul; Choi, Sangjun; Kim, Chinyon; Yoon, Chungsik; Park, Dooyong; Paek, Domyung
2010-11-01
This paper presents a summary of arsenic level statistics from air and wipe samples taken from studies conducted in fabrication operations. The main objectives of this study were not only to describe arsenic measurement data but also, through a literature review, to categorize fabrication workers in accordance with observed arsenic levels. All airborne arsenic measurements reported were included in the summary statistics for analysis of the measurement data. The arithmetic mean was estimated assuming a lognormal distribution from the geometric mean and the geometric standard deviation or the range. In addition, weighted arithmetic means (WAMs) were calculated based on the number of measurements reported for each mean. Analysis of variance (ANOVA) was employed to compare arsenic levels classified according to several categories such as the year, sampling type, location sampled, operation type, and cleaning technique. Nine papers were found reporting airborne arsenic measurement data from maintenance workers or maintenance areas in semiconductor chip-making plants. A total of 40 statistical summaries from seven articles were identified that represented a total of 423 airborne arsenic measurements. Arsenic exposure levels taken during normal operating activities in implantation operations (WAM = 1.6 μg m⁻³, no. of samples = 77, no. of statistical summaries = 2) were found to be lower than exposure levels of engineers who were involved in maintenance works (7.7 μg m⁻³, no. of samples = 181, no. of statistical summaries = 19). The highest level (WAM = 218.6 μg m⁻³) was associated with various maintenance works performed inside an ion implantation chamber. ANOVA revealed no significant differences in the WAM arsenic levels among the categorizations based on operation and sampling characteristics. Arsenic levels (56.4 μg m⁻³) recorded during maintenance works performed in dry conditions were found to be much higher than those from maintenance works in wet conditions (0.6 μg m⁻³). Arsenic levels from wipe samples in process areas after maintenance activities ranged from non-detectable to 146 μg cm⁻², indicating the potential for dispersion into the air and hence inhalation. We conclude that workers who are regularly or occasionally involved in maintenance work have higher potential for occupational exposure than other employees who are in charge of routine production work. In addition, fabrication workers can be classified into two groups based on the reviewed arsenic exposure levels: operators with potential for low levels of exposure and maintenance engineers with high levels of exposure. These classifications could be used as a basis for a qualitative ordinal ranking of exposure in an epidemiological study.
Dismantling of the PETRA glove box: tritium contamination and inventory assessment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wagner, R.
2015-03-15
The PETRA facility is the first installation in which experiments with tritium were carried out at the Tritium Laboratory Karlsruhe. After completion of two main experimental programs, the decommissioning of PETRA was initiated with the aim to reuse the glove box and its main still valuable components. A decommissioning plan was engaged to: -) identify the source of tritium release in the glove box, -) clarify the status of the main components, -) assess residual tritium inventories, and -) de-tritiate the components to be disposed of as waste. Several analytical techniques - calorimetry on small solid samples, wipe test followedmore » by liquid scintillation counting for surface contamination assessment, gas chromatography on gaseous samples - were deployed and cross-checked to assess the remaining tritium inventories and initiate the decommissioning process. The methodology and the main outcomes of the numerous different tritium measurements are presented and discussed. (authors)« less
X-Ray Fluorescence Solvent Detection at the Substrate-Adhesive Interface
NASA Technical Reports Server (NTRS)
Wurth, Laura; Evans, Kurt; Weber, Bart; Headrick, Sarah
2005-01-01
With environmental regulations limiting the use of volatile organic compounds, low-vapor pressure solvents have replaced traditional degreasing solvents for bond substrate preparation. When used to clean and prepare porous bond substrates such as phenolic composites, low vapor pressure solvents can penetrate deep into substrate pore networks and remain there for extended periods. Trapped solvents can interact with applied adhesives either prior to or during cure, potentially compromising bond properties. Currently, methods for characterizing solvent time-depth profiles in bond substrates are limited to bulk gravimetric or sectioning techniques. While sectioning techniques such as microtome allow construction of solvent depth profiles, their depth resolution and reliability are limited by substrate type. Sectioning techniques are particularly limited near the adhesive-substrate interface where depth resolution is further limited by adhesive-substrate hardness and, in the case of a partially cured adhesive, mechanical properties differences. Additionally, sectioning techniques cannot provide information about lateral solvent diffusion. Cross-section component mapping is an alternative method for measuring solvent migration in porous substrates that eliminates the issues associated with sectioning techniques. With cross-section mapping, the solvent-wiped substrate is sectioned perpendicular rather than parallel to the wiped surface, and the sectioned surface is analyzed for the solvent or solvent components of interest using a two-dimensional mapping or imaging technique. Solvent mapping can be performed using either direct or indirect methods. With a direct method, one or more solvent components are mapped using red or Raman spectroscopy together with a moveable sample stage and/or focal plane array detector. With an indirect method, an elemental "tag" not present in the substrate is added to the solvent before the substrate is wiped. Following cross sectioning, the tag element can then be mapped by its characteristic x-ray emission using either x-ray fluorescence, or electron-beam energy-and wavelength-dispersive x-ray spectrometry. The direct mapping techniques avoid issues of different diffusion or migration rates of solvents and elemental tags, while the indirect techniques avoid spectral resolution issues in cases where solvents and substrates have adjacent or overlapping peaks. In this study, cross-section component indirect mapping is being evaluated as a method for measuring migration of d-limonene based solvents in glass-cloth phenolic composite (GCP) prior to and during subsequent bonding and epoxy adhesive cure.
Goldcamp, Michael J; Goldcamp, Diane M; Ashley, Kevin; Fernback, Joseph E; Agrawal, Anoop; Millson, Mark; Marlow, David; Harrison, Kenneth
2009-12-01
Beryllium exposure can cause a number of deleterious health effects, including beryllium sensitization and the potentially fatal chronic beryllium disease. Efficient methods for monitoring beryllium contamination in workplaces are valuable to help prevent dangerous exposures to this element. In this work, performance data on the extraction of beryllium from various size fractions of high-fired beryllium oxide (BeO) particles (from < 32 microm up to 212 microm) using dilute aqueous ammonium bifluoride (ABF) solution were obtained under various conditions. Beryllium concentrations were determined by fluorescence using a hydroxybenzoquinoline fluorophore. The effects of ABF concentration and volume, extraction temperature, sample tube types, and presence of filter or wipe media were examined. Three percent ABF extracts beryllium nearly twice as quickly as 1% ABF; extraction solution volume has minimal influence. Elevated temperatures increase the rate of extraction dramatically compared with room temperature extraction. Sample tubes with constricted tips yield poor extraction rates owing to the inability of the extraction medium to access the undissolved particles. The relative rates of extraction of Be from BeO of varying particle sizes were examined. Beryllium from BeO particles in fractions ranging from less than 32 microm up to 212 microm were subjected to various extraction schemes. The smallest BeO particles are extracted more quickly than the largest particles, although at 90 degrees C even the largest BeO particles reach nearly quantitative extraction within 4 hr in 3% ABF. Extraction from mixed cellulosic-ester filters, cellulosic surface-sampling filters, wetted cellulosic dust wipes, and cotton gloves yielded 90% or greater recoveries. Scanning electron microscopy of BeO particles, including partially dissolved particles, shows that dissolution in dilute ABF occurs not just on the exterior surface but also via accessing particles' interiors due to porosity of the BeO material. Comparison of dissolution kinetics data shows that as particle diameter approximately doubles, extraction time is increased by a factor of about 1.5, which is consistent with the influence of porosity on dissolution.
McClure, Elizabeth M; Goldenberg, Robert L; Brandes, Neal; Darmstadt, Gary L; Wright, Linda L
2009-01-01
Of the 4 million neonatal deaths and 500,000 maternal deaths that occur annually worldwide, almost 99% are in developing countries and one-third are associated with infections. Implementation of proven interventions and targeted research on a select number of promising high-impact preventative and curative interventions are essential to achieve Millennium Development Goals for reduction of child and maternal mortality. Feasible, simple, low-cost interventions have the potential to significantly reduce the mortality and severe morbidity associated with infection in these settings. Studies of chlorhexidine in developing countries have focused on three primary uses: 1) intrapartum vaginal and neonatal wiping, 2) neonatal wiping alone, and 3) umbilical cord cleansing. A study of vaginal wiping and neonatal skin cleansing with chlorhexidine, conducted in Malawi in the 1990s suggested that chlorhexidine has potential to reduce neonatal infectious morbidity and mortality. A recent trial of cord cleansing conducted in Nepal also demonstrated benefit. Although studies have shown promise, widespread acceptance and implementation of chlorhexidine use has not yet occurred. This paper is derived in part from data presented at a conference on the use of chlorhexidine in developing countries and reviews the available evidence related to chlorhexidine use to reduce mortality and severe morbidity due to infections in mothers and neonates in low-resource settings. It also summarizes issues related to programmatic implementation. PMID:17399714
Abdullah, A F Lim; Miskelly, Gordon M
2010-04-15
Evaluation of the risk posed by contaminants present during and after decontamination of clandestine methamphetamine laboratories requires a connection between the levels of contaminants measured and those actually present at the scene. The recoveries of pseudoephedrine and methamphetamine from glass, stainless steel, and a range of impermeable surfaces likely to be found in a clandestine laboratory were examined, using GC-MS of derivatized samples as the analytical method. When surfaces had been cleaned prior to drug deposition, wiping with water-dampened filter paper can recover 60-80% of pseudoephedrine immediately after deposition, and at least 50% of the pseudoephedrine still present on a surface after 2 days when deposited at a surface concentration of 2.5 microg/100 cm(2). Wiping with methanol-dampened filter paper could recover 60-90% of the methamphetamine immediately after deposition, and could recover at least 50-60% of the methamphetamine still present after 2 days when 0.6 microg/100 cm(2) was initially deposited on the surface. Recoveries were lower for surfaces that had not been pre-cleaned. Methamphetamine and pseudoephedrine showed significant volatility in both the free base and hydrochloride forms, with experiments in an enclosed format showing up to half the recovered drug being present on a glass plate held about 4mm above a substrate contaminated with one of the drugs at the above surface concentrations after 2 days. It is therefore important to remove any visible bulk contaminants and remove obvious pseudoephedrine or methamphetamine-contaminated surfaces prior to heating, ventilation or sealing of a clandestine laboratory to avoid redistribution of material around the site. A revised method for pseudoephedrine analysis was developed that could also detect the pseudoephedrine-formaldehyde adduct that can form from trace pseudoephedrine present at clandestine laboratories. (c) 2009 Elsevier B.V. All rights reserved.
... Use the applicator brush attached to the bottle cap to apply ciclopirox topical solution evenly to all ... can reach these areas. Wipe off the bottle cap and neck and replace the cap tightly on ...
... instilling the next drop. Replace and tighten the cap on the dropper bottle. Do not wipe or ... someone else apply the gel. Remove the protective cap. Avoid touching the tip of the tube against ...
... your hands with soap and water. Dip a cotton swab into a skin-cleaning solution, such as ... or another antiseptic your provider recommends. Use the cotton swab to wipe and scrub around one pin ...
Tebbutt, G. M.
1988-01-01
A comparison of five methods of cleaning Formica surfaces contaminated with bacteria dried in milk has been carried out. A standardized procedure was developed, and impression plates were found to be at least as sensitive as a swab-rinse method for detecting bacteria on the surfaces. The most satisfactory results were obtained with one type of disposable alcohol-impregnated wipe and with a detergent/hypochlorite solution applied with paper. A reusable cloth impregnated with disinfectant initially performed well against all test organisms, but was less reliable against Staphylococcus aureus and Streptococcus faecalis, after the cloth had been used and rinsed several times. The importance of introducing methods to reduce the high risk of cross-contamination presently associated with the use of wiping cloths in catering premises is stressed. PMID:3141202
Short-term markers of DNA damage among roofers who work with hot asphalt.
Serdar, Berrin; Brindley, Stephen; Dooley, Greg; Volckens, John; Juarez-Colunga, Elizabeth; Gan, Ryan
2016-10-20
Roofers are at increased risk for various malignancies and their occupational exposures to polycyclic aromatic hydrocarbons (PAHs) have been considered as important risk factors. The overall goal of this project was to investigate the usefulness of phosphorylated histone H2AX (γH2AX) as a short-term biomarker of DNA damage among roofers. Blood, urine, and dermal wipe samples were collected from 20 roofers who work with hot asphalt before and after 6 h of work on Monday and Thursday of the same week (4 sampling periods). Particle-bound and gas-phase PAHs were collected using personal monitors during work hours. γH2AX was quantified in peripheral lymphocytes using flow cytometry and 8-hydroxy-2-deoxyguanosine (8-OHdG) was assessed in urine using ELISA. General linear mixed models were used to evaluate associations between DNA damage and possible predictors (such as sampling period, exposure levels, work- and life-style factors). Differences in mean biomarker and DNA damage levels were tested via ANOVA contrasts. Exposure measurements did not show an association with any of the urinary biomarkers or the measures of DNA damage. Naphthalene was the most abundant PAH in gas-phase, while benzo(e)pyrene was the most abundant particle-bound PAH. Post-shift levels of γH2AX and 8-OHdG were higher on both study days, when compared to pre-shift levels. Cigarette smoking was a predictor of γH2AX and urinary creatinine was a predictor of urinary 8-OHdG. Between-subject variance to total variance ratio was 35.3 % for γH2ax and 4.8 % for 8-OHdG. γH2AX is a promising biomarker of DNA damage in occupational epidemiology studies. It has a lower within-subject variation than urinary 8-OHdG and can easily be detected in large scale groups. Future studies that explore the kinetics of H2AX phosphorylation in relation to chemical exposures may reveal the transient and persistent nature of this sensitive biomarker of early DNA damage.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bibby, R; Guthrie, E
2009-01-30
The instrument has four collection vials that must be filled with ethylene glycol before operation. Each of the four vials should be labeled 1 through 4 and the empty weights recorded. Fill each vial with 80 mL of ethylene glycol and record the weight again. In order for the instrument to operate properly, the collection vials should always have less than 160 mL of total liquid in them. After completing a sample run, remove the collection vials, use a transfer pipette to remove any liquid that might still be on the air paddler, wipe off any condensation from the exteriormore » of the collection vial and record weight. From the instrument, record the ending volume and the time of operation. The solution mixed in the scintillation vial will be 2 ml of a 95% to 50% ethylene glycol to water mixture. To determine the efficiency of counting at all of these concentrations, a series of vials should be set up that consist of 18 ml of Ultima Gold LLT cocktail mixed with standard, regular deionized water and ethylene glycol. The efficiency curve should be counted in the 'Low Level' count mode with the Luminescence Correction ON and the Color Quench Correction ON. Once the tSIE values are determined, chart the cpm against the tSIE numbers and find the best fit for the data. The resulting equation is to be used to converting tSIE values from the collection vials to efficiency. To determine the background cpm value of the ethylene glycol, count a 2 ml sample of ethylene glycol with 18 ml of Ultima Gold for 100 minutes. To determine the total activity of the sample, take two 2 ml aliquots of sample from the first vial and place in separate scintillation vials. Record the weight of each aliquot. Determine the percentage of total sample each aliquot represents by dividing the aliquot weight by the total solution weight from the vial. Also, determine the percentage of ethylene glycol in the sample by dividing the initial solution weight by the final solution weight and multiplying by 100. Add 18 ml of Ultima Gold to each vial and proceed to count for 100 minutes in a 'Low Level' count mode. Before performing a calculation on the dpm value of each aliquot, a subtraction should be made for the background count rate of the ethylene glycol. Based on the background cpm, multiply the background cpm value by the percentage of ethylene glycol in the collection vial. Once the background value is subtracted, calculate the dpm value of the sample based on the tSIE conversion to efficiency. This will produce a dpm value. To convert this to a total activity of the sample, divide the aliquot dpm value by the decimal percentage of total sample the aliquot represents. This gives the total activity of the sample solution. Take the average of both aliquots as a final result. To convert the total activity from the solution in vial one to activity in air, an empirical formula is used to convert activity/gram from vial one to total activity introduced into the system. After calculation the final result for the vial, divide the total by the mass of the sample in vial one. This gives dpm/g (labeled C{sub m}). To convert this to total dpm measured, C = (128.59 * Cm + 10.837)/V Where: C = Tritium concentration in air (dpm/m{sup 3}) C{sub m} = measured tritium concentration from vial 1 (dpm/g) V = Volume of air sampled through instrument (m{sup 3}). C is the final value of tritium concentration in air.« less
... administer the injection, follow these steps: Clean the injection site with an alcohol wipe using a circular motion, ... to pinch a fold of skin at the injection site. Do not lay the syringe down or allow ...
... injuries are things like fractures , sprains and strains , concussions , and cuts . They usually happen after a blow or force — like getting tackled in football or wiping out while skateboarding. Overuse injuries include ...
... wipe furniture. Rug Deodorizer Liberally sprinkle carpets with baking soda. Wait at least 15 minutes and vacuum. ... with one teaspoon of salt, one teaspoon of baking soda and a sheet of aluminum foil. Totally ...
Pirbuterol Acetate Oral Inhalation
... Pirbuterol is in a class of medications called beta-agonist bronchodilators. It works by relaxing and opening ... cleaning. Once a week, remove the mouthpiece cover, turn the inhaler upside down and wipe the mouthpiece ...
Hydrocortisone, Neomycin, and Polymyxin
... your pharmacist or doctor. Replace and tighten the cap or dropper right away. Wash your hands to ... instilling the next drop. Replace and tighten the cap on the dropper bottle. Do not wipe or ...
Oughton, Matthew T; Loo, Vivian G; Dendukuri, Nandini; Fenn, Susan; Libman, Michael D
2009-10-01
To evaluate common hand hygiene methods for efficacy in removing Clostridium difficile. Randomized crossover comparison among 10 volunteers with hands experimentally contaminated by nontoxigenic C. difficile. Interventions included warm water with plain soap, cold water with plain soap, warm water with antibacterial soap, antiseptic hand wipes, alcohol-based handrub, and a control involving no intervention. All interventions were evaluated for mean reduction in colony-forming units (CFUs) under 2 contamination protocols: "whole hand" and "palmar surface." Results were analyzed according to a Bayesian approach, by using hierarchical models adjusted for multiple observations. Under the whole-hand protocol, the greatest adjusted mean reductions were achieved by warm water with plain soap (2.14 log(10) CFU/mL [95% credible interval (CrI), 1.74-2.54 log(10) CFU/mL]), cold water with plain soap (1.88 log(10) CFU/mL [95% CrI, 1.48-2.28 log(10) CFU/mL), and warm water with antibacterial soap (1.51 log(10) CFU/mL [95% CrI, 1.12-1.91 log(10) CFU/mL]), followed by antiseptic hand wipes (0.57 log(10) CFU/mL [95% CrI, 0.17-0.96 log(10) CFU/mL]). Alcohol-based handrub (0.06 log(10) CFU/mL [95% CrI, -0.34 to 0.45 log(10) CFU/mL]) was equivalent to no intervention. Under the palmar surface protocol, warm water with plain soap, cold water with plain soap, and warm water with antibacterial soap again yielded the greatest mean reductions, followed by antiseptic hand wipes (26.6, 26.6, 26.6, and 21.9 CFUs per plate, respectively), when compared with alcohol-based handrub. Hypothenar (odds ratio, 10.98 [95% CrI, 1.96-37.65]) and thenar (odds ratio, 6.99 [95% CrI, 1.25-23.41]) surfaces were more likely than fingertips to remain heavily contaminated after handwashing. Handwashing with soap and water showed the greatest efficacy in removing C. difficile and should be performed preferentially over the use of alcohol-based handrubs when contact with C. difficile is suspected or likely.
Cognitive representations of AIDS: a phenomenological study.
Anderson, Elizabeth H; Spencer, Margaret Hull
2002-12-01
Cognitive representations of illness determine behavior. How persons living with AIDS image their disease might be key to understanding medication adherence and other health behaviors. The authors' purpose was to describe AIDS patients' cognitive representations of their illness. A purposive sample of 58 men and women with AIDS were interviewed. Using Colaizzi's (1978) phenomenological method, rigor was established through application of verification, validation, and validity. From 175 significant statements, 11 themes emerged. Cognitive representations included imaging AIDS as death, bodily destruction, and just a disease. Coping focused on wiping AIDS out of the mind, hoping for the right drug, and caring for oneself. Inquiring about a patient's image of AIDS might help nurses assess coping processes and enhance nurse-patient relationships.
Food Safety While Hiking, Camping and Boating
... list. Carry items like dried pasta, rice, and baking mixes in plastic bags and take only the ... away from fresh water. Some wilderness campers use baking soda to wash their utensils. Pack disposable wipes ...
Peripherally inserted central catheter - dressing change
... chlorhexidine) in a single-use small applicator Special sponges or wipes that contain a cleaning agent, such ... Clean your skin around the site with the sponge and cleaning solution for 30 seconds. Let the ...
A computational model for doctoring fluid films in gravure printing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hariprasad, Daniel S., E-mail: dshari@unm.edu; Grau, Gerd; Schunk, P. Randall
2016-04-07
The wiping, or doctoring, process in gravure printing presents a fundamental barrier to resolving the micron-sized features desired in printed electronics applications. This barrier starts with the residual fluid film left behind after wiping, and its importance grows as feature sizes are reduced, especially as the feature size approaches the thickness of the residual fluid film. In this work, various mechanical complexities are considered in a computational model developed to predict the residual fluid film thickness. Lubrication models alone are inadequate, and deformation of the doctor blade body together with elastohydrodynamic lubrication must be considered to make the model predictivemore » of experimental trends. Moreover, model results demonstrate that the particular form of the wetted region of the blade has a significant impact on the model's ability to reproduce experimental measurements.« less
Contamination removal using various solvents and methodologies
NASA Technical Reports Server (NTRS)
Jeppsen, J. C.
1989-01-01
Critical and non-critical bonding surfaces must be kept free of contamination that may cause potential unbonds. For example, an aft-dome section of a redesigned solid rocket motor that had been contaminated with hydraulic oil did not appear to be sufficiently cleaned when inspected by the optically stimulated electron emission process (Con Scan) after it had been cleaned using a hand double wipe cleaning method. As a result, current and new cleaning methodologies as well as solvent capability in removing various contaminant materials were reviewed and testing was performed. Bonding studies were also done to verify that the cleaning methods used in removing contaminants provide an acceptable bonding surface. The removal of contaminants from a metal surface and the strength of subsequent bonds were tested using the Martin Marietta and double-wipe cleaning methods. Results are reported.
Kotwal, Grishma; Harrison, Mark A.; Law, S. Edward; Harrison, Judy A.
2013-01-01
Human noroviruses are major etiologic agents of epidemic gastroenteritis. Outbreaks are often accompanied by contamination of environmental surfaces, but since these viruses cannot be routinely propagated in laboratory cultures, their response to surface disinfectants is predicted by using surrogates, such as murine norovirus 1 (MNV-1). This study compared the virucidal efficacies of various liquid treatments (three sanitizer liquids, 5% levulinic acid plus 2% SDS [LEV/SDS], 200 ppm chlorine, and an isopropanol-based quaternary ammonium compound [Alpet D2], and two control liquids, sterile tap water and sterile tap water plus 2% SDS) when delivered to MNV-1-inoculated stainless steel surfaces by conventional hydraulic or air-assisted, induction-charged (AAIC) electrostatic spraying or by wiping with impregnated towelettes. For the spray treatments, LEV/SDS proved effective when applied with hydraulic and AAIC electrostatic spraying, providing virus reductions of 2.71 and 1.66 log PFU/ml, respectively. Alpet D2 provided a 2.23-log PFU/ml reduction with hydraulic spraying, outperforming chlorine (1.16-log PFU/ml reduction). Chlorine and LEV/SDS were equally effective as wipes, reducing the viral load by 7.05 log PFU/ml. Controls reduced the viral load by <1 log with spraying applications and by >3 log PFU/ml with wiping. Results indicated that both sanitizer type and application methods should be carefully considered when choosing a surface disinfectant to best prevent and control environmental contamination by noroviruses. PMID:23263949
Kusumaningrum, H D; Paltinaite, R; Koomen, A J; Hazeleger, W C; Rombouts, F M; Beumer, R R
2003-12-01
Effective cleaning and sanitizing of food preparation sites is important because pathogens are readily spread to food contact surfaces after preparation of contaminated raw products. Tolerance of Salmonella Enteritidis and Staphylococcus aureus to surface cleaning by wiping with regular, microfiber, and antibacterial-treated cloths was investigated. Wiping with cleaning cloths resulted in a considerable reduction of microorganisms from surfaces, despite the greater difficulty in removing S. aureus than Salmonella Enteritidis. Depending on the cloth type, S. aureus were reduced on surfaces from initial numbers of approximately 10(5) CFU/100 cm2 to numbers from less than 4 CFU/100 cm2 (below the detection limit) to 100 CFU/100 cm2. Directly after the cloths were used to clean the contaminated surfaces, they contained high numbers of bacteria (10(4) to 10(5) CFU/100 cm2), except for the disposable antibacterial-treated cloths, in which no bacteria could be detected. The tolerance of these pathogens to sodium hypochlorite was studied in the suspension test and in cloths. S. aureus showed a better tolerance for sodium hypochlorite than Salmonella Enteritidis. Inactivation of microorganisms in cloths required a higher concentration of sodium hypochlorite than was needed in the suspension test. Repeated exposure to sodium hypochlorite, however, resulted in an increase in susceptibility to this compound. This study provides essential information about the transfer of bacteria when wiping surfaces and highlights the need for a hygiene procedure with cleaning cloths that sufficiently avoids cross-contamination in the household environment.
Removal of biofilm from contact lens storage cases.
Wu, Yvonne T; Zhu, Hua; Willcox, Mark; Stapleton, Fiona
2010-12-01
Lens case hygiene practices are important in maintaining safe contact lens wear. However, the effectiveness of various lens case cleaning practices have not been evaluated and compared. This in vitro study aimed to evaluate and compare the efficacy of cleaning practices that are most commonly carried out by lens wearers and recommended by practitioners. Pseudomonas aeruginosa 122, Serratia marcescens ATCC 13880, and Staphylococcus aureus ATCC 6538 were the challenge bacteria for biofilm formation on unused lens cases from two different manufacturers. After establishment of the biofilm, each lens case was subjected to one of the six cleaning regimens: "rinsed," "rubbed and rinsed," "air-dried," "soaked in a multipurpose contact lens solution," "tissue-wiped," and "lids recapped." The level of residual biofilm was quantified at the end of each cleaning regimen. The efficacy of each cleaning regimen was then compared. Mechanical rubbing and wiping of lens cases were the most effective cleaning regimen tested in reducing biofilm. Soaking lenses in disinfecting solution for 6 hours removed the majority of biofilm from lens cases. Rinsing lens cases alone provided only minimal efficacy in reducing biofilm. Air-drying or recapping the cases with the lid without any other additional cleaning methods were the least efficient at removing biofilm. Based on this study, digital rubbing and rinsing and/or wiping the lens cases with tissue is recommended. Air-drying or recapping the lens case lids after use without any additional cleaning methods should be discouraged with non-antimicrobial lens cases.
Goodyear, Nancy; Markkanen, Pia; Beato-Melendez, Christian; Mohamed, Hagir; Gore, Rebecca; Galligan, Catherine; Sama, Susan; Quinn, Margaret
2018-04-01
Home care aides perform personal care and homemaking services in client homes, including cleaning and disinfection (C&D). Although C&D are performed to remove soil and dust, they are increasingly performed for infection prevention. Many C&D products contain respiratory irritants. The objective of this study was to evaluate 2 commercial products for C&D effectiveness on common household surfaces in seniors' homes. Two C&D visits were conducted in 46 seniors' homes. One visit applied a bleach-containing cleaning product and the other applied an environmentally preferable product. Before and after C&D, the study team performed organic soil bioluminometer measurements on surfaces and collected cotton swab and wipe samples for total bacteria count, Staphylococcus aureus, and Clostridium difficile identification. Both products removed microorganisms from tested surfaces. S aureus was found in 7 households, 1 strain of which was methicillin-resistant. Both products removed S aureus from all surfaces. Bleach-containing products removed somewhat more soil than environmentally preferable products, although results were statistically significant for only 1 surface. The study showed similar, not identical, C&D performance for 2 cleaning products with potentially different consequences for respiratory health. Additional research is needed to develop robust recommendations for safe, effective C&D in home care. Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
A survey of occupational exposure to 4,4'-methylene-bis (2-chloroaniline) (MbOCA) in the UK.
Cocker, J; Cain, J R; Baldwin, P; McNally, K; Jones, K
2009-07-01
The main objective of the study was to gather information about the current controls and levels of exposure to 4,4'-methylene-bis (2-chloroaniline) (MbOCA) in a representative cross section of workplaces that use it to manufacture polyurethane elastomers. The study also aimed to investigate whether controls and guidance could be improved and to investigate exposure to isocyanates in these workplaces using biological monitoring. An occupational hygienist and a field scientist visited the two UK suppliers and 20 out of the 25 workplaces known to be using MbOCA in the UK during 2005 and 2006. They collected air samples, surface wipes, gloves, and urine samples and made observations to assess exposure and the adequacy of controls. All samples were analysed for MbOCA and urine samples were additionally analysed for isocyanate metabolites. A statistical analysis was made of the results. Only 2.5% of the 80 personal inhalation exposures to MbOCA exceeded the workplace exposure limit of 5 microg m(-3) 8-h time-weighted average and 84% were below the limit of detection (LOD). Surface samples (n = 334) were collected from MbOCA users and suppliers and 60% had detectable levels of MbOCA ranging from 0.019 to 400 microg cm(-2). The highest levels were around a hopper, ovens, and the weighing and pouring areas. MbOCA was also detected in 8 of the 75 samples collected from areas not likely to be in contact with MbOCA. At the two suppliers, samples (n = 28) were collected from the outside surfaces of recently imported kegs, pallets, and the floor around kegs. Six samples had detectable levels and four of these (0.2, 0.8, 1, and 6 microg cm(-2)) were from the floor and pallets in both suppliers. The other two positive results were found on the outside rim (18 microg cm(-2)) and side (23 microg cm(-2)) of a keg at one supplier indicating contamination by the manufacturer. Urine samples (n = 79) were collected and 49% were below the LOD for MbOCA and only three samples had levels of MbOCA that exceeded the biological monitoring guidance value (BMGV) of 15 micromol mol(-1) creatinine. The highest urinary MbOCA concentrations were in samples from workers casting and moulding. The 90th percentile of the urine MbOCA results was 8.6 micromol MbOCA per mol creatinine. Urine samples were also analysed for the diamine metabolites of toluene diisocyanate and hexamethylene diisocyanate and 33% had detectable levels with 22 and 13% of results, respectively, above the BMGV for isocyanates (1 micromol isocyanate-derived diamine per mol creatinine). The maximum urinary concentration of toluene diamine and hexane diamine were 15.6 and 10.1 micromol mol(-1) creatinine, respectively. The survey found that the measures used to control exposure to MbOCA could be improved. Although air levels of MbOCA were generally low, there was evidence of spread of surface contamination and poor maintenance of controls such as local exhaust ventilation. A BMGV based on the 90th percentile of data from workplaces with good control would be less than the 90% value of 8.6 micromol mol(-1) creatinine found in this study and suggests that the current BMGV of 15 micromol mol(-1) creatinine is no longer acting as a stimulus to reduce exposure. The metabolites of isocyanates found in urine samples in this study could arise from inhalation exposure to isocyanates or from dermal exposure to either isocyanates or their diamine breakdown product and need further investigation.
Evolution: How Some Birds Survived When All Other Dinosaurs Died.
Brusatte, Stephen L
2016-05-23
The end-Cretaceous mass extinction wiped out the dinosaurs, including many birds. But some bird lineages survived. May seed-eating have been the key? Copyright © 2016 Elsevier Ltd. All rights reserved.
Adult Catheter Care and Infection Prevention Guide
... or diluted bleach; and wipe with a clean paper towel. Work at a comfortable pace -- the risk ... soap (including under fingernails). • Dry with a clean paper towel. Turn water off with the back of ...
MATISSE 2.0: New Ideas to Support Planetary Sciences
NASA Astrophysics Data System (ADS)
Zinzi, A.; Longobardo, A.; Giardino, M.; Ivanovski, S.; Capria, M. T.; Palomba, E.
2018-04-01
The next version of MATISSE will be a brand-new one, so that, without wiping out the successful modular structure of the current version, a number of newly introduced solutions can allow overcoming existing limitations.
PESTICIDE RESIDUE RECOVERIES FROM SURFACE WIPES
Human exposure is a consequence of pesticide use indoors with a primary source resulting from residue deposition on household surfaces. Accurate measurements of surface residues is essential for estimating exposure from different routes. Various procedures have been developed ...
Karunaweera, Nadira D; Galappaththy, Gawrie Nl; Wirth, Dyann F
2014-02-18
Malaria is one of the most important tropical diseases that has caused devastation throughout the history of mankind. Malaria eradication programmes in the past have had many positive effects but failed to wipe out malaria from most tropical countries, including Sri Lanka. Encouraged by the impressive levels of reduction in malaria case numbers during the past decade, Sri Lanka has launched a programme to eliminate malaria by year 2014. This article reviews the historical milestones associated with the malaria eradication programme that failed subsequently and the events that led to the launch of the ongoing malaria elimination plans at national-level and its strategies that are operational across the entire country. The existing gaps in knowledge are also discussed together with the priority areas for research to fill in these gaps that are posing as challenges to the envisaged goal of wiping out malaria from this island nation.
Chemical Prey Luring in Jackson's Chameleons.
Preest, Marion R; Ward, Matthew J; Poon, Thomas; Hermanson, John W
2016-01-01
Lizards in the family Chamaeleonidae have been described as wiping a viscous substance from a pouch (the temporal pouch) at the angle of the jaw on branches and then capturing flies that land near the area where the wiping occurs. We confirmed the presence of this pouch in Jackson's chameleons. Histological work suggested that the material contained within is a result of decomposition of food and sloughed skin that has been trapped in the pouch rather than a glandular secretion. Gas chromatography-mass spectrometry indicated the presence of compounds that are both volatile and odiferous and similar to insect pheromones. Choice tests with houseflies revealed attraction to the temporal pouch material. Some authors have speculated that the temporal pouch material serves a function in territory marking and/or predator deterrence. While it may play these roles, our results suggest that it also plays a role in chemical luring of prey.
Nonhazardous solvent composition and method for cleaning metal surfaces
Googin, John M.; Simandl, Ronald F.; Thompson, Lisa M.
1993-01-01
A solvent composition for displacing greasy and oily contaminants as well as water and/or aqueous residue from metallic surfaces, especially surfaces of radioactive materials so that such surfaces can be wiped clean of the displaced contaminants, water and/or aqueous residue. The solvent composition consists essentially of a blend of nonpolar aliphatic hydrocarbon solvent having a minimum flash point of about 140.degree. F. and 2 to 25 volume percent of a polar solvent having a flash point sufficiently high so as to provide the solvent composition with a minimum flash point of at least 140.degree. F. The solvent composition is nonhazardous so that when it is used to clean the surfaces of radioactive materials the waste in the form of paper or cloth wipes, lab coats and the like used in the cleaning operation is not considered to be mixed waste composed of a hazardous solvent and a radioactive material.
Nonhazardous solvent composition and method for cleaning metal surfaces
Googin, J.M.; Simandl, R.F.; Thompson, L.M.
1993-05-04
A solvent composition for displacing greasy and oily contaminants as well as water and/or aqueous residue from metallic surfaces, especially surfaces of radioactive materials so that such surfaces can be wiped clean of the displaced contaminants, water and/or aqueous residue. The solvent composition consists essentially of a blend of nonpolar aliphatic hydrocarbon solvent having a minimum flash point of about 140 F and 2 to 25 volume percent of a polar solvent having a flash point sufficiently high so as to provide the solvent composition with a minimum flash point of at least 140 F. The solvent composition is nonhazardous so that when it is used to clean the surfaces of radioactive materials the waste in the form of paper or cloth wipes, lab coats and the like used in the cleaning operation is not considered to be mixed waste composed of a hazardous solvent and a radioactive material.
FY 2017 Center Innovation Fund Annual Report - Highlights/Abstract section
NASA Technical Reports Server (NTRS)
Hintze, Paul; Youngquist, Robert C.; Massa, Gioia D.; Meier, Anne J.
2017-01-01
This project evaluated the feasibility of low pressure cold plasma (CP) for two applications: disinfection of produce grown in space and sterilization of medical equipment in space. Currently there is no ISS capability for disinfecting pick and eat crops, food utensils, food production areas, or medical devices. This deficit is extended to projected long duration missions. Small, portable, cold plasma devices would provide an enhanced benefit to crew health and address issues concerning microbial cross contamination. The technology would contribute to the reduction of solid waste since currently crews utilize benzalkonium chloride wet wipes for cleaning surfaces and might use PRO-SAN wipes for cleaning vegetables. CP cleaning/disinfection/sterilization can work on many surfaces, including all metals, most polymers, and this project evaluated produce. Therefore CP provides a simple system that has many different cleaning application in space: produce, medical equipment, cutlery, miscellaneous tools.
Wang, Zhengbao; Ge, Qinqin; Shao, Jia; Yan, Yushan
2009-05-27
We demonstrate for the first time that by one single hydrothermal synthesis a zeolite LTA membrane with a high flux of 9.0 kg/m(2) h and high water/ethanol separation factor of 10,000 could be formed on a ceramic hollow fiber that is known for its ability to form a compact module. The flux is the highest reported in the literatures. A novel seeding method, dipcoating-wiping, is key to obtaining zeolite membranes with high separation performance because it reproducibly produces a uniform and trace seed layer on the support. This new seeding method is expected to have serious implications for making defect-free zeolite films and membranes for many applications. The membranes reported here have the potential to solve the key problems that have prevented zeolite membranes from widespread use for biofuel production.
Sampling the stratum corneum for toxic chemicals.
Coman, Garrett; Blickenstaff, Nicholas R; Blattner, Collin M; Andersen, Rosa; Maibach, Howard I
2014-01-01
Dermal exposure is an important pathway in environmental health. Exposure comes from contaminated water, soil, treated surfaces, textiles, aerosolized chemicals, and agricultural products. It can occur in homes, schools, play areas, and work settings in the form of industrial sources, consumer products, or hazardous wastes. Dermal exposure is most likely to occur through contact with liquids, water, soil, sediment, and contaminated surfaces. The ability to detect and measure exposure to toxic materials on the skin is an important environmental health issue. The stratum corneum is the skin's first and principal barrier layer of protection from the outside world. It has a complex structure that can effectively protect against a wide variety of physical, chemical, and biological contaminants. However, there are a variety of chemical agents that can damage the stratum corneum and the underlying epidermis, dermis and subcutis, and/or enter systemic circulation through the skin. There are numerous ways of sampling the stratum corneum for these toxic materials like abrasion techniques, biopsy, suction blistering, imaging, washing, wipe sampling, tape stripping, and spot testing. Selecting a method likely depends on the particular needs of the situation. Hence, there is a need to review practical considerations for their use in sampling the stratum corneum for toxins.
Gallistl, Christoph; Sprengel, Jannik; Vetter, Walter
2018-02-15
Fat obtained by wipe tests on the inner surface of 21 baking ovens from Stuttgart (Germany) were analyzed for halogenated flame retardants (HFRs), namely polybrominated diphenyl ethers (PBDEs), decabromodiphenyl ethane (DBDPE), dechlorane plus (DP), short- and medium-chain chlorinated paraffins (SCCPs, MCCPs), as well as polychlorinated biphenyls (PCBs). In ~50% of the samples chlorinated paraffins (CPs) were present in the mg/g fat range, i.e. three to four orders of magnitude higher concentrated than the sum of all other target compounds. In contrast the remaining ~50% of the samples were free of CPs, while the other HFRs were comparable in CP-positive and CP-negative samples. The exceptionally high concentrations and exclusive presence of CPs in half of the samples produced strong evidence that these compounds were released from the baking oven itself. This hypothesis was supported by detection of MCCPs at even higher concentrations in the inner components of one dismantled baking oven. The release of substantial amounts of HFRs from the oven casing during its use may contribute to human exposure to these compounds, especially MCCPs and SCCPs. Copyright © 2017 Elsevier B.V. All rights reserved.
Occupational exposure to cytotoxic drugs in two UK oncology wards
Ziegler, E; Mason, H; Baxter, P
2002-01-01
Aims: To investigate the potential exposure to cytotoxic drugs of staff on two oncology wards in a large district, UK hospital under normal working conditions. Methods: Cytotoxic drug exposure was monitored in urine samples, surface wipes, and on disposable gloves by using a number of commonly used marker drugs, namely cyclophosphamide, ifosfamide, methotrexate, and the platino coordinated drugs. Questionnaire data on their work practices, potential exposure, use of protective personal equipment, and relevant training were collected from nursing, domestic, and clerical staff on two oncology wards. Results: The majority of staff were female with a mean age of 31 years. Roughly half of the staff studied were specifically trained nurses with an average of 3.5 years experience of administering cytotoxic drugs. No cytotoxic drug preparation or reconstitution was carried out on the wards. Disposable gloves, plastic armlets and aprons, but not eye protection, were invariably worn where there was potential exposure to cytotoxics. No cytotoxic drug was detected in any of the staff's urine samples. Isolated disposable latex gloves from nurses administering drugs showed some contamination, as did some surfaces within the wards' sluice rooms, but not in the ward areas where the drugs were stored and checked prior to administration. Conclusions: The risk management strategies in place, including use of personal protective equipment, staff training, and other organisational measures, have ensured that internal exposure is lower than the detection limits for the current biological monitoring methods. Levels of contamination appear significantly lower than earlier, non-UK published studies where different risk management strategies were in place and, in particular, ward staff may have been involved in some degree of cytotoxic drug reconstitution. PMID:12205233
Hood, Nancy E; Ferketich, Amy K; Klein, Elizabeth G; Pirie, Phyllis; Wewers, Mary Ellen
2014-01-01
Smoke-free policies are being increasingly promoted and adopted in subsidised multiunit housing to address disparities in residential secondhand smoke exposure. In order to inform the planning and evaluation of these policies, this study examined associations between self-reported in-home smoking and surface nicotine concentrations. A face-to-face, cross-sectional survey was conducted from August to October 2011 with leaseholders in a probability sample of private subsidised housing units in Columbus, Ohio, without an existing smoke-free housing policy (n=301, 64% response rate). After the survey, a wipe sample was collected from a wood surface in the living room to measure surface nicotine concentrations (n=279). In-home smoking was reported by 56.6% of respondents. Geometric mean surface nicotine concentrations differed between non-smoking and smoking homes (11.4 vs 90.9 μg/m(2); p<0.001), and between homes with complete, partial and no voluntary home smoking restrictions (8.9 vs 56.3 vs 145.6 μg/m(2); p<0.001). Surface nicotine concentrations were moderately correlated (r=.52) with the total number of cigarettes smoked indoors per week. Smoking behaviours of respondents, other household members and visitors, and length of stay were independently associated with surface nicotine concentrations in a multivariable model, explaining 52% of the variance. Surface nicotine concentrations were significantly associated with a range of self-reported in-home smoking behaviours. This measure should be considered for evaluating changes in in-home smoking behaviours after implementation of smoke-free policies by subsidised housing providers. More research is needed about how surface nicotine concentrations differ over space, time and various indoor surfaces.
Buescher, D L; Möllers, M; Falkenberg, M K; Amler, S; Kipp, F; Burdach, J; Klockenbusch, W; Schmitz, R
2016-05-01
Transvaginal and intracavitary ultrasound probes are a possible source of cross-contamination with microorganisms and thus a risk to patients' health. Therefore appropriate methods for reprocessing are needed. This study was designed to compare the standard disinfection method for transvaginal ultrasound probes in Germany with an automated disinfection method in a clinical setting. This was a prospective randomized controlled clinical study of two groups. In each group, 120 microbial samples were collected from ultrasound transducers before and after disinfection with either an automated method (Trophon EPR®) or a manual method (Mikrozid Sensitive® wipes). Samples were then analyzed for microbial growth and isolates were identified to species level. Automated disinfection had a statistically significantly higher success rate of 91.4% (106/116) compared with 78.8% (89/113) for manual disinfection (P = 0.009). The risk of contamination was increased by 2.9-fold when disinfection was performed manually (odds ratio, 2.9 (95% CI, 1.3-6.3)). Before disinfection, bacterial contamination was observed on 98.8% of probes. Microbial analysis revealed 36 different species of bacteria, including skin and environmental bacteria as well as pathogenic bacteria such as Staphylococcus aureus, enterobacteriaceae and Pseudomonas spp. Considering the high number of contaminated probes and bacterial species found, disinfection of the ultrasound probe's body and handle should be performed after each use to decrease the risk of cross-contamination. This study favored automated disinfection owing to its significantly higher efficacy compared with a manual method. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd.
Indoor air quality investigation and health risk assessment at correctional institutions.
Ofungwu, Joseph
2005-04-01
A comprehensive indoor air-quality (IAQ) investigation was conducted at a state correctional facility in New Jersey, USA with a lengthy history of IAQ problems. The IAQ investigation comprised preliminary indoor air screening using direct readout instrumentation, indoor air/surface wipe sampling and laboratory analysis, as well as a heating, ventilation, and air-conditioning system evaluation, and a building envelope survey. In addition to air sampling, a human health risk assessment was performed to evaluate the potential for exposure to site-related air contaminants with respect to the inmate and worker populations. The risk assessment results for the prison facility indicated the potential for significant health risks for the inmate population, possibly reflecting the effects of their confinement and extended exposure to indoor air contaminants, as compared to the prison guard and worker population. Based on the results of the risk assessment, several mitigation measures are recommended to minimize prison population health risks and improve indoor air quality at prison facilities.
Cloth-covered chiropractic treatment tables as a source of allergens and pathogenic microbes.
Evans, Marion W; Campbell, Alan; Husbands, Chris; Breshears, Jennell; Ndetan, Harrison; Rupert, Ronald
2008-03-01
Vinyl chiropractic tables have been found to harbor pathogenic bacteria, but wiping with a simple disinfection agent can significantly reduce the risk of bacteria. The aim of this study was to assess the presence of microbes and other allergens or pathogens on cloth chiropractic tables. Cloth-covered tables in a chiropractic college teaching clinic were selected. Samples were taken from the facial piece and hand rests with RODAC plates containing nutrient agar, followed by confirmatory testing when indicated. Numerous microbacteria strains were found, including Staphylococcus aureus and Propionibacterium. Allergen-producing molds, including Candida, were also found. Cloth tables were shown to contain pathogenic microbacteria and allergens. The chiropractic profession should establish an infection control protocol relevant to treatment tables and discard use of cloth-covered treatment tables in this process.
Electronic cigarettes are a source of thirdhand exposure to nicotine.
Goniewicz, Maciej L; Lee, Lily
2015-02-01
Substances remaining on the surfaces in areas where people have smoked contribute to thirdhand exposure. Nicotine from tobacco smoke has been shown to react with oxidizing chemicals in the air to form secondary pollutants, such as carcinogenic nitrosamines. While previous studies have demonstrated thirdhand exposure to nicotine from tobacco smoke, none have investigated whether nicotine from electronic cigarettes (e-cigarettes) can also be deposited on various surfaces. Three brands of e-cigarettes were refilled with varying nicotine concentrations. We released 100 puffs from each product directly into an exposure chamber. Surface wipe samples were taken from 5 indoor 100 cm(2) surfaces (window, walls, floor, wood, and metal) pre- and post-release of vapors. Nicotine was extracted from the wipes and was analyzed using gas chromatography. Three of the 4 experiments showed significant increases in the amount of nicotine on all five surfaces. The floor and glass windows had the greatest increases in nicotine, on average by a factor of 47 and 6, respectively (p < .05). The average amount of nicotine deposited on a floor during each experiment was 205 μg/m(2) and varied from limit of quantitation to 550 μg/m(2). This study indicates that there is a risk for thirdhand exposure to nicotine from e-cigarettes. Thirdhand exposure levels differ depending on the surface and the e-cigarette brand. Future research should explore the potential risks of thirdhand exposure to carcinogens formed from the nicotine that is released from e-cigarettes. © The Author 2014. Published by Oxford University Press on behalf of the Society for Research on Nicotine and Tobacco. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Pinturaud, Marine; Soichot, Marion; Richeval, Camille; Humbert, Luc; Lebecque, Michèle; Sidikou, Ousseini; Barthelemy, Christine; Bonnabry, Pascal; Allorge, Delphine; Décaudin, Bertrand; Odou, Pascal
2016-01-01
Background The objective of this randomized, prospective and controlled study was to investigate the ability of a closed-system transfer device (CSTD; BD-Phaseal) to reduce the occupational exposure of two isolators to 10 cytotoxic drugs and compare to standard compounding devices. Methods and Findings The 6-month study started with the opening of a new compounding unit. Two isolators were set up with 2 workstations each, one to compound with standard devices (needles and spikes) and the other using the Phaseal system. Drugs were alternatively compounded in each isolator. Sampling involved wiping three surfaces (gloves, window, worktop), before and after a cleaning process. Exposure to ten antineoplastic drugs (cyclophosphamide, ifosfamide, dacarbazine, 5-FU, methotrexate, gemcitabine, cytarabine, irinotecan, doxorubicine and ganciclovir) was assessed on wipes by LC-MS/MS analysis. Contamination rates were compared using a Chi2 test and drug amounts by a Mann-Whitney test. Significance was defined for p<0.05. Overall contamination was lower in the “Phaseal” isolator than in the “Standard” isolator (12.24% vs. 26.39%; p < 0.0001) although it differed according to drug. Indeed, the contamination rates of gemcitabine were 49.3 and 43.4% (NS) for the Standard and Phaseal isolators, respectively, whereas for ganciclovir, they were 54.2 and 2.8% (p<0.0001). Gemcitabine amounts were 220.6 and 283.6 ng for the Standard and Phaseal isolators (NS), and ganciclovir amounts were 179.9 and 2.4 ng (p<0.0001). Conclusion This study confirms that using a CSTD may significantly decrease the chemical contamination of barrier isolators compared to standard devices for some drugs, although it does not eliminate contamination totally. PMID:27391697
Evaluation of various cleaning methods to remove bacillus spores from spacecraft hardware materials
NASA Technical Reports Server (NTRS)
Venkateswaran, Kasthuri; Chung, Shirley; Allton, Judith; Kern, Roger
2004-01-01
A detailed study was made of the biological cleaning effectiveness, defined in terms of the ability to remove bacterial spores, of a number of methods used to clean hardware surfaces. Aluminum (Al 6061) and titanium (Ti 6Al-4V) were chosen for the study as they were deemed the two materials most likely to be used in spacecraft extraterrestrial sampler construction. Metal coupons (1 cm x 2.5 cm) were precleaned and inoculated with 5.8 x 10(3) cultivable Bacillus subtilis spores, which are commonly found on spacecraft surfaces and in the assembly environments. The inoculated coupons were subsequently cleaned using: (1) 70% isopropyl alcohol wipe; (2) water wipe; (3) multiple-solvent flight-hardware cleaning procedures used at the Jet Propulsion Laboratory (JPL); (4) Johnson Space Center-developed ultrapure water rinse; and (5) a commercial, semi-aqueous, multiple-solvent (SAMS) cleaning process. The biological cleaning effectiveness was measured by agar plate assay, sterility test (growing in liquid media), and epifluorescent microscopy. None of the cleaning protocols tested completely removed viable spores from the surface of the aluminum. In contrast, titanium was capable of being cleaned to sterility by two methods, the JPL standard and the commercial SAMS cleaning process. Further investigation showed that the passivation step employed in the JPL standard method is an effective surface sterilant on both metals but not compatible with aluminum. It is recommended that titanium (Ti 6Al-4V) be considered superior to aluminum (Al 6061) for use in spacecraft sampling hardware, both for its potential to be cleaned to sterilization and for its ability to withstand the most effective cleaning protocols.
Evaluation of Various Cleaning Methods to Remove Bacillus Spores from Spacecraft Hardware Materials
NASA Astrophysics Data System (ADS)
Venkateswaran, Kasthuri; Chung, Shirley; Allton, Judith; Kern, Roger
2004-09-01
A detailed study was made of the biological cleaning effectiveness, defined in terms of the ability to remove bacterial spores, of a number of methods used to clean hardware surfaces. Aluminum (Al 6061) and titanium (Ti 6Al-4V) were chosen for the study as they were deemed the two materials most likely to be used in spacecraft extraterrestrial sampler construction. Metal coupons (1 cm × 2.5 cm) were precleaned and inoculated with 5.8 × 103 cultivable Bacillus subtilis spores, which are commonly found on spacecraft surfaces and in the assembly environments. The inoculated coupons were subsequently cleaned using: (1) 70% isopropyl alcohol wipe; (2) water wipe; (3) multiple-solvent flight-hardware cleaning procedures used at the Jet Propulsion Laboratory (JPL); (4) Johnson Space Center-developed ultrapure water rinse; and (5) a commercial, semi-aqueous, multiple-solvent (SAMS) cleaning process. The biological cleaning effectiveness was measured by agar plate assay, sterility test (growing in liquid media), and epifluorescent microscopy. None of the cleaning protocols tested completely removed viable spores from the surface of the aluminum. In contrast, titanium was capable of being cleaned to sterility by two methods, the JPL standard and the commercial SAMS cleaning process. Further investigation showed that the passivation step employed in the JPL standard method is an effective surface sterilant on both metals but not compatible with aluminum. It is recommended that titanium (Ti 6Al-4V) be considered superior to aluminum (Al 6061) for use in spacecraft sampling hardware, both for its potential to be cleaned to sterilization and for its ability to withstand the most effective cleaning protocols.
Evaluation of various cleaning methods to remove bacillus spores from spacecraft hardware materials.
Venkateswaran, Kasthuri; Chung, Shirley; Allton, Judith; Kern, Roger
2004-01-01
A detailed study was made of the biological cleaning effectiveness, defined in terms of the ability to remove bacterial spores, of a number of methods used to clean hardware surfaces. Aluminum (Al 6061) and titanium (Ti 6Al-4V) were chosen for the study as they were deemed the two materials most likely to be used in spacecraft extraterrestrial sampler construction. Metal coupons (1 cm x 2.5 cm) were precleaned and inoculated with 5.8 x 10(3) cultivable Bacillus subtilis spores, which are commonly found on spacecraft surfaces and in the assembly environments. The inoculated coupons were subsequently cleaned using: (1) 70% isopropyl alcohol wipe; (2) water wipe; (3) multiple-solvent flight-hardware cleaning procedures used at the Jet Propulsion Laboratory (JPL); (4) Johnson Space Center-developed ultrapure water rinse; and (5) a commercial, semi-aqueous, multiple-solvent (SAMS) cleaning process. The biological cleaning effectiveness was measured by agar plate assay, sterility test (growing in liquid media), and epifluorescent microscopy. None of the cleaning protocols tested completely removed viable spores from the surface of the aluminum. In contrast, titanium was capable of being cleaned to sterility by two methods, the JPL standard and the commercial SAMS cleaning process. Further investigation showed that the passivation step employed in the JPL standard method is an effective surface sterilant on both metals but not compatible with aluminum. It is recommended that titanium (Ti 6Al-4V) be considered superior to aluminum (Al 6061) for use in spacecraft sampling hardware, both for its potential to be cleaned to sterilization and for its ability to withstand the most effective cleaning protocols.
Corneal Sensitivity Following Lacrimal Gland Excision in the Rat
Meng, Ian D.; Barton, Stephen T.; Mecum, Neal E.; Kurose, Masayuki
2015-01-01
Purpose. Dry eye disease (DED) produces ocular pain and irritation, yet a detailed characterization of ocular sensitivity in a preclinical model of DED is lacking. The aim of the present study was to assess nociceptive behaviors in an aqueous tear deficiency model of DED in the rat. Methods. Spontaneous blinking, corneal mechanical thresholds, and eye wipe behaviors elicited by hypertonic saline (5.0 M) were examined over a period of 8 weeks following the unilateral excision of either the exorbital lacrimal gland or of the exorbital and infraorbital lacrimal glands, and in sham surgery controls. The effect of topical proparacaine on spontaneous blinking and of systemic morphine (0.5–3.0 mg/kg, subcutaneous [SC]) on spontaneous blinking and eye wipe responses were also examined. Results. Lacrimal gland excision resulted in mechanical hypersensitivity and an increase in spontaneous blinking in the ipsilateral eye over an 8-week period that was more pronounced after infra- and exorbital gland excision. The time spent eye wiping was also enhanced in response to hypertonic saline (5.0 M) at both 1- and 8-week time-points, but only in infra- and exorbital gland excised animals. Morphine attenuated spontaneous blinking, and the response to hypertonic saline in dry eye animals and topical proparacaine application reduced spontaneous blinking down to control levels. Conclusions. These results indicate that aqueous tear deficiency produces hypersensitivity in the rat cornea. In addition, the increase in spontaneous blinks and their reduction by morphine and topical anesthesia indicate the presence of persistent irritation elicited by the activation of corneal nociceptors. PMID:26024120
Microbiological cleanliness of the Mars Exploration Rover spacecraft
NASA Technical Reports Server (NTRS)
Newlin, L.; Barengoltz, J.; Chung, S.; Kirschner, L.; Koukol, R.; Morales, F.
2002-01-01
Planetary protection for Mars missions is described, and the approach being taken by the Mars Exploration Rover Project is discussed. Specific topics include alcohol wiping, dry heat microbial reduction, microbiological assays, and the Kennedy Space center's PHSF clean room.
Giving an IM (intramuscular) injection
... Wash your hands well with soap and water. Dry them. Carefully find the spot where you will give the injection. Clean the skin at that spot with an alcohol wipe. Let it dry. Take the cap off the needle. Hold the ...
Food packets for use on the Gemini 3 flight
NASA Technical Reports Server (NTRS)
1965-01-01
Food packets for use on the Gemini 3 flight including dehydrated beef pot roast, bacon and egg bites, toasted bread cubes, orange juice and a wet wipe. Water is being inserted into the pouch of dehydrated food.
Emergency preparedness for those who care for infants in developed country contexts
2011-01-01
Emergency management organisations recognise the vulnerability of infants in emergencies, even in developed countries. However, thus far, those who care for infants have not been provided with detailed information on what emergency preparedness entails. Emergency management authorities should provide those who care for infants with accurate and detailed information on the supplies necessary to care for them in an emergency, distinguishing between the needs of breastfed infants and the needs of formula fed infants. Those who care for formula fed infants should be provided with detailed information on the supplies necessary for an emergency preparedness kit and with information on how to prepare formula feeds in an emergency. An emergency preparedness kit for exclusively breastfed infants should include 100 nappies and 200 nappy wipes. The contents of an emergency preparedness for formula fed infants will vary depending upon whether ready-to-use liquid infant formula or powdered infant formula is used. If ready-to-use liquid infant formula is used, an emergency kit should include: 56 serves of ready-to-use liquid infant formula, 84 L water, storage container, metal knife, small bowl, 56 feeding bottles and teats/cups, 56 zip-lock plastic bags, 220 paper towels, detergent, 120 antiseptic wipes, 100 nappies and 200 nappy wipes. If powdered infant formula is used, an emergency preparedness kit should include: two 900 g tins powdered infant formula, 170 L drinking water, storage container, large cooking pot with lid, kettle, gas stove, box of matches/lighter, 14 kg liquid petroleum gas, measuring container, metal knife, metal tongs, feeding cup, 300 large sheets paper towel, detergent, 100 nappies and 200 nappy wipes. Great care with regards hygiene should be taken in the preparation of formula feeds. Child protection organisations should ensure that foster carers responsible for infants have the resources necessary to formula feed in the event of an emergency. Exclusive and continued breastfeeding should be promoted as an emergency preparedness activity by emergency management organisations as well as health authorities. The greater the proportion of infants exclusively breastfed when an emergency occurs, the more resilient the community, and the easier it will be to provide effective aid to the caregivers of formula fed infants. PMID:22059481
Decontamination of Surfaces Exposed to Carbonbased Nanotubes and Nanomaterials
NASA Astrophysics Data System (ADS)
Karimi, Zahra
Contamination of surfaces by nanomaterials can happen due to accidental spillage and release or gradual accumulation during processing or handling. Considering the increasingly wide use of nanomaterials in industry and research labs and also taking into account the diversity of physical and chemical properties of different nanomaterials (such as solubility, aggregation/agglomeration, and surface reactivity), there is a pressing need to define reliable nanomaterial-specific decontamination guidelines. In this project, we propose and investigate a potential method for surface decontamination of carbon-based nanomaterials using solvent cleaning and wipes. The results show that the surfactant-assisted removal efficiencies of multi-walled carbon nanotubes, single walled carbon nantubes and single walled carbon nano-horns from silicon wafers through wiping is greater than 95%, 90% and 78%, respectively. The need for further studies to understand the mechanisms of nanomaterial removal from surfaces and development of standard techniques for surface decontamination of nanomaterials is highlighted. Another phase of experiments were performed to examine the efficiency of surfactants to remove multi-walled carbon nanotubes (MWCNTs) from silicon substrates with nano and microscaled features. In the first set of experiments, nanoscale features were induced on silicon wafers using SF6 and O2 plasma. Atomic force microscopy (AFM) was used to observe the surface topology and roughness. In the second set, well-defined microscale topological features were induced on silicon wafers using photo lithography and plasma etching. The etching time was varied to create semi-ellipsoidal pits with average diameter and height of ~ 7-9 microm, and ~ 1-3 microm, respectively. MWCNTs in the form of liquid solution were deposited on the surface of silicon wafers using the spin coating process. For the cleaning process, the contaminated surfaces were first sprayed with different types of surfactant or water. Then, the MWCNTs were wiped off using a simple wiping mechanism. The areal density of the MWCNTs was quantified prior to and after the removal using scanning electron microscopy (SEM) and post-image processing. For a surface featured with nanoscale asperities, the removal efficiency was measured to be in the range 83-99% based on substrate type and surface roughness. No evident relationship was observed between the etching time and the removal efficiency. For microscale features, increase of the etching time significantly decreases the removal efficiency.
Lunter, Dominique Jasmin
2016-01-01
The aim of the study was to elucidate the effect of sample preparation and microscope configuration on the results of confocal Raman microspectroscopic evaluation of the penetration of a pharmaceutical active into the skin (depth profiling). Pig ear skin and a hydrophilic formulation containing procaine HCl were used as a model system. The formulation was either left on the skin during the measurement, or was wiped off or washed off prior to the analysis. The microscope configuration was varied with respect to objectives and pinholes used. Sample preparation and microscope configuration had a tremendous effect on the results of depth profiling. Regarding sample preparation, the best results could be observed when the formulation was washed off the skin prior to the analysis. Concerning microscope configuration, the use of a 40 × 0.6 numerical aperture (NA) objective in combination with a 25-µm pinhole or a 100 × 1.25 NA objective in combination with a 50-µm pinhole was found to be advantageous. Complete removal of the sample from the skin before the analysis was found to be crucial. A thorough analysis of the suitability of the chosen microscope configuration should be performed before acquiring concentration depth profiles. © 2016 S. Karger AG, Basel.
Prevalence of Influenza A Virus in Exhibition Swine during Arrival at Agricultural Fairs.
Bliss, N; Nelson, S W; Nolting, J M; Bowman, A S
2016-09-01
The exhibition swine at agricultural fairs provides a critical human-swine interface that allows for the bidirectional transmission of influenza A virus (IAV). Previous IAV surveillance at the end of fairs has resulted in frequent detection of IAV-infected swine; little is known, however, about the frequency with which swine arrive at fairs already infected with IAV. We investigated the IAV prevalence among exhibition swine entering fairs to better understand the epidemiology of IAV in this unique human-swine interface. In 2014, snout wipes were collected from 3547 swine during the first day of nine agricultural exhibitions in Indiana and Ohio. Samples were screened for IAV using rRT-PCR and positive samples were inoculated into cultured cells for virus isolation. The overall IAV prevalence detected among swine arriving at exhibitions was 5.3% (188/3547) via rRT-PCR and 1.5% (53/3547) via virus isolation, with IAV being detected and recovered from swine at 5 of the 9 exhibitions. Within the fairs with IAV-positive swine, the individual exhibition IAV prevalence ranged from 0.2% (1/523) to 34.4% (144/419) using rRT-PCR and 0.2% (1/523) to 10.3% (43/419) with virus isolation. Single IAV subtypes were detected at three of the fairs but subtype diversity was detected among the pigs at two fairs as both H1N1 and H3N2 were recovered from incoming swine. At two of the exhibitions, a temporal relationship was observed between the order of the individual swine in sampling and the associated IAV rRT-PCR results, indicating the fomite transmission of IAV through common contact surfaces may occur. With the knowledge that a small proportion of swine arrive at fairs shedding IAV, resources should be directed towards preventive strategies focused on limiting transmission during fairs to protect swine and humans during exhibitions. © 2016 Blackwell Verlag GmbH.
2014-01-01
Background Hospital cleanliness in hospitals with a tendency toward long-term care in Japan remains unevaluated. We therefore visualized hospital cleanliness in Japan over a 2-month period by two distinct popular methods: ATP bioluminescence (ATP method) and the standard stamp agar method (stamp method). Methods The surfaces of 752 sites within nurse and patient areas in three hospitals located in a central area of Sapporo, Japan were evaluated by the ATP and stamp methods, and each surface was sampled 8 times in 2 months. These areas were located in different ward units (Internal Medicine, Surgery, and Obstetrics and Gynecology). Detection limits for the ATP and stamp methods were determined by spike experiments with a diluted bacterial solution and a wipe test on student tables not in use during winter vacation, respectively. Values were expressed as the fold change over the detection limit, and a sample with a value higher than the detection limit by either method was defined as positive. Results The detection limits were determined to be 127 relative light units (RLU) per 100 cm2 for the ATP method and 5.3 colony-forming units (CFU) per 10 cm2 for the stamp method. The positive frequency of the ATP and stamp methods was 59.8% (450/752) and 47.7% (359/752), respectively, although no significant difference in the positive frequency among the hospitals was seen. Both methods revealed the presence of a wide range of organic contamination spread via hand touching, including microbial contamination, with a preponderance on the entrance floor and in patient rooms. Interestingly, the data of both methods indicated considerable variability regardless of daily visual assessment with usual wiping, and positive surfaces were irregularly seen. Nurse areas were relatively cleaner than patient areas. Finally, there was no significant correlation between the number of patients or medical personnel in the hospital and organic or microbiological contamination. Conclusions Ongoing daily hospital cleanliness is not sufficient in Japanese hospitals with a tendency toward long-term care. PMID:24593868
Perez, Angela L; Liong, Monty; Plotkin, Kevin; Rickabaugh, Keith P; Paustenbach, Dennis J
2017-01-01
This study provides an exposure and risk assessment of diundecyl phthalate (DUP), a high molecular weight phthalate plasticizer present in automobile interiors. Total daily intake of DUP was calculated from DUP measured in wipe samples from vehicle seats from six automobiles. Four of the vehicles exhibited atypical visible surface residue on the seats. Two vehicles with no visible surface residue were sampled as a comparison. DUP was the predominant organic compound identified in each of the wipes from all seats. A risk assessment of DUP via oral, dermal, and inhalation routes resulting from contact with automobile seats was conducted. The mean, standard deviation, and maximum DUP concentrations on the seats with visible surface residue were 6983 ± 7823 μg/100 cm 2 and 38300 μg/100 cm 2 , respectively. The mean and 95th percentile of the mean for daily cumulative dose of DUP for all exposure routes for the seats with no visible surface residue ranged from 7 × 10 -4 to 4 × 10 -3 mg/kg-day and from 8 × 10 -4 to 5 × 10 -3 mg/kg-day, respectively. For seats with visible surface residue, cumulative doses ranged from 2 × 10 -3 to 2 × 10 -2 mg/kg-day and from 4 × 10 -3 to 2 × 10 -2 mg/kg-day, respectively. The estimated daily intake (contact or absorbed dose) of DUP from automobile seats were far lower than the NOAELs reported in and derived from animal studies, and are well below the reported Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH) Derived No Effect Levels (DNELs) for the general population. Based on this analysis, using virtually any benchmark for evaluating safety, exposure to DUP via automobile seat covers did not pose a measureable increased health-risk in any population under any reasonably plausible exposure scenario. Copyright © 2016 Elsevier Ltd. All rights reserved.
Watanabe, Reina; Shimoda, Tomoko; Yano, Rika; Hayashi, Yasuhiro; Nakamura, Shinji; Matsuo, Junji; Yamaguchi, Hiroyuki
2014-03-04
Hospital cleanliness in hospitals with a tendency toward long-term care in Japan remains unevaluated. We therefore visualized hospital cleanliness in Japan over a 2-month period by two distinct popular methods: ATP bioluminescence (ATP method) and the standard stamp agar method (stamp method). The surfaces of 752 sites within nurse and patient areas in three hospitals located in a central area of Sapporo, Japan were evaluated by the ATP and stamp methods, and each surface was sampled 8 times in 2 months. These areas were located in different ward units (Internal Medicine, Surgery, and Obstetrics and Gynecology). Detection limits for the ATP and stamp methods were determined by spike experiments with a diluted bacterial solution and a wipe test on student tables not in use during winter vacation, respectively. Values were expressed as the fold change over the detection limit, and a sample with a value higher than the detection limit by either method was defined as positive. The detection limits were determined to be 127 relative light units (RLU) per 100 cm2 for the ATP method and 5.3 colony-forming units (CFU) per 10 cm2 for the stamp method. The positive frequency of the ATP and stamp methods was 59.8% (450/752) and 47.7% (359/752), respectively, although no significant difference in the positive frequency among the hospitals was seen. Both methods revealed the presence of a wide range of organic contamination spread via hand touching, including microbial contamination, with a preponderance on the entrance floor and in patient rooms. Interestingly, the data of both methods indicated considerable variability regardless of daily visual assessment with usual wiping, and positive surfaces were irregularly seen. Nurse areas were relatively cleaner than patient areas. Finally, there was no significant correlation between the number of patients or medical personnel in the hospital and organic or microbiological contamination. Ongoing daily hospital cleanliness is not sufficient in Japanese hospitals with a tendency toward long-term care.
Gemini-Titan (GT)-4 Foods - Documentary Use
1965-01-07
S65-10971 (March 1965 ) --- Food packets for use on the Gemini-3 flight including dehydrated beef pot roast, bacon and egg bites, toasted bread cubes, orange juice and a wet wipe. Water is being inserted into the pouch of dehydrated food.
Endangered Species and Human Survival.
ERIC Educational Resources Information Center
Regenstein, Lewis
1984-01-01
In wiping out the natural heritage over which we were given dominion and stewardship responsibilities, we are sowing the seeds of our own destruction. With the advent of the Reagan administration, the government's endangered species program has all but ceased to function. (RM)
Editorial: Children's Books on the Rack.
ERIC Educational Resources Information Center
Heins, Ethel L.
1980-01-01
Discusses and deplores two recent assaults on alleged sexism, racism, and prejudice against the handicapped in children's literary classics; states the author's agreement with another author's belief that people cannot legislate their literary heritage without wiping out most of the world's literature. (GT)
ESTIMATING EXCESS DIETARY EXPOSURES OF YOUNG CHILDREN
Nine children in a daycare that routinely applied the pesticide, esfenvalerate, were studied to assess excess dietary exposures. Surface wipes, a standard food item of processed American cheese slice pressed on the surface and handled by the child, an accelerometer reading, and ...
NASA Astrophysics Data System (ADS)
Li, Pengyuan; Li, Tao; Gu, Qiuyun; Chen, Xiaomin; Li, Jiahui; Chen, Xiashi; Chen, Yan; Zhang, Danwei; Gao, Rong; He, Zhenjian; Zhu, Xun; Zhang, Wangjian; Hao, Yuantao; Zhang, Dingmei
2016-11-01
Hand-foot-and-mouth disease (HFMD) is a common infectious disease, which has led to millions of clinical cases and hundreds of deaths every year in China. This study aimed to exploring the effects on HFMD transmission of children’s caregivers and public area, as well as trying to locate the potential reservoirs of infections in primary cases. Total children’s 257 samples (98 children’s caregivers and 159 environmental samples) were tested for the presence of universal enterovirus, enterovirus 71, coxsackie virus A6 and A16 by real-time fluorescence quantitative polymerase chain reaction (qPCR). 5.84% (15/257, 95% confidence interval [CI]: 2.98%, 8.70%) of total samples had positive results of enterovirus. The enterovirus positive rates of children’s caregiver samples and environmental samples were respectively 7.14% (7/98, 95% CI: 2.04%, 12.24%), and 5.03% (8/159, 95% CI: 1.63%, 8.43%); 7.61% (7/92, 95% CI: 2.21%, 13.01%) of wiping samples from playgrounds and 1.49% (1/67, 95% CI: 0, 7.00%) of air samples in indoor market places had positive result of enterovirus. High positive rates of enterovirus in children’s caregivers and from playgrounds indicated that they would be potential reservoirs of HFMD infection, as children might be infected via contacting with asymptomatic-infected individuals or exposure of contaminated surface of public facilities.
... enough to prevent normal speaking and swallowing. Home Care If the plant was eaten, wipe out the mouth with a ... to Expect at the Emergency Room Take the plant with you to the hospital, if possible. The health care provider will measure and monitor the person's vital ...
40 CFR 52.515 - Original identification of plan section.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Natural Resources and Environmental Control. (19) The Plan revision entitled “Revisions to the..., Cylinder wipe, Emission unit, Federally enforceable, Flexography, Fugitive emission, Gas services, Gas..., Freeboard ratio, Mayor, Vehicular fuel tank. Abbreviations: (Degree), VOC, “%”. (ii) Additional material. (A...
Potential development of a new cotton-based antimicrobial wipe
USDA-ARS?s Scientific Manuscript database
The adsorption of alkyl-dimethyl-benzyl-ammonium chloride (ADBAC), a cationic surfactant commonly employed as an antimicrobial agent, on greige and bleached nonwoven cotton fabrics was investigated using UV/visible spectroscopy. Initial results have shown that greige cotton adsorbs roughly three tim...
Potential development of a new cotton-based antimicrobial wipe
USDA-ARS?s Scientific Manuscript database
The adsorption of a cationic biocide on various cotton and synthetic nonwoven fabrics was investigated using UV-Vis absorption spectroscopy. The results reveal that rayon and greige cotton nonwovens adsorb nearly three times more cationic biocide than comparable bleached cotton substrates. Polyester...
USDA research enables total quat release from cotton nonwoven disinfecting wipes
USDA-ARS?s Scientific Manuscript database
The adsorption of alkyl-dimethyl-benzyl-ammonium chloride (ADBAC), a cationic surfactant commonly employed as an antimicrobial agent, on various cotton, cotton-blend, and synthetic nonwoven fabrics was investigated at varying surfactant concentrations using UV-Vis absorption spectroscopy. Modifying ...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-22
... entered into this docket is available on the World Wide Web at http://www.regulations.gov . FOR FURTHER... association, business, labor union, etc.). You may review DOT's complete Privacy Act Statement in the Federal...
Gong, Mengyan; Weschler, Charles J; Zhang, Yinping
2016-04-19
Clothing can either retard or accelerate dermal exposure to phthalates. To investigate the impact of clothing on dermal exposure to six phthalates (DMP/DEP/DiBP/DnBP/BBzP/DEHP) in real environments, two sets of experiments have been conducted: (1) Skin wipes were collected from 11 adults to examine the phthalate levels on both bare-skin (hand/forehead) and clothing-covered body locations (arm/back/calf); (2) Five adults were asked to wear just-washed jeans for 1 day (1(st) experiment), 5 days (2(nd) experiment), and 10 days (3(rd) experiment). Phthalate levels on their legs were measured on selected days during the wearing period, and phthalate levels in the jeans were measured at the end of each experiment and again after washing. Measured phthalate levels on body locations covered by clothing were lower than those on uncovered locations, but still substantial. Dermal uptake would be underestimated by a factor of 2 to 5 if absorption through body locations covered by clothing were neglected. Phthalate levels in the jeans and on the legs increased with the wearing time. However, the levels in the jeans and on the legs were not strongly correlated, indicating that other pathways, e.g, contact with bedding or bedclothes, likely contribute to the levels on the legs. The efficiency with which laundering washing removed phthalates from the jeans increased with decreasing Kow; median values ranged from very low (<5%) for DEHP to very high (∼75%) for DMP.
Emanuel, Ivor A; Blaiss, Michael S; Meltzer, Eli O; Evans, Philip; Connor, Alyson
2014-01-01
Sensory attributes of intranasal corticosteroids, such as rundown to the back of the throat, may influence patient treatment preferences. This study compares the nasal deposition and nasal retention of a radiolabeled solution of ciclesonide nasal aerosol (CIC-hydrofluoroalkane [HFA]) with a radiolabeled suspension of mometasone furoate monohydrate aqueous nasal spray (MFNS) in subjects with either perennial allergic rhinitis (AR) or seasonal AR. In this open-label, single-dose, randomized, crossover scintigraphy study, 14 subjects with symptomatic AR received a single dose of radiolabeled 74-μg CIC-HFA (37 μg/spray, 1 spray/each nostril) via a nasal metered-dose inhaler or a single dose of radiolabeled 200-μg MFNS (50 μg/spray, 2 sprays/each nostril), with a minimum 5-day washout period between treatments. Initial deposition (2 minutes postdose) of radiolabeled CIC-HFA and MFNS in the nasal cavity, nasopharynx, and on nasal wipes, and retention of radioactivity in the nasal cavity and nasal run-out on nasal wipes at 2, 4, 6, 8, and 10 minutes postdose were quantified with scintigraphy. At 2 and 10 minutes postdose, deposition of radiolabeled CIC-HFA was significantly higher in the nasal cavity versus radiolabeled MFNS (99.42% versus 86.50% at 2 minutes, p = 0.0046; and 81.10% versus 54.31% at 10 minutes, p < 0.0001, respectively; p values unadjusted for multiplicity). Deposition of radioactivity on nasal wipes was significantly higher with MFNS versus CIC-HFA at all five time points, and posterior losses of radiolabeled formulation were significantly higher with MFNS at 6, 8, and 10 minutes postdose. In this scintigraphic study, significantly higher nasal deposition and retention of radiolabeled aerosol CIC-HFA were observed versus radiolabeled aqueous MFNS in subjects with AR.
Korb, Donald R; Blackie, Caroline A; Finnemore, Victor M; Douglass, Teresa
2015-04-01
The aim of this study was to assess the efficacy of using a combination treatment approach consisting of lipid emulsion eye drops, eyelid cleansing wipes, and omega-3 vitamin supplements compared with warm compresses in improving meibomian gland functionality in patients with lipid-deficient/evaporative dry eye disease (LDDE). This single-center, open-label, investigator-masked, randomized study enrolled patients aged ≥18 years, clinically diagnosed with LDDE defined as having ≤6 functional meibomian glands [meibomian gland yielding liquid secretion (MGYLS)] and positive for dry eye symptoms at screening. Patients were randomized to receive either the combination treatment (lipid emulsion eye drops, omega-3 supplements, and lid hygiene with eyelid wipes) or to apply warm, wet compresses once daily, 8 minutes per day, for 3 months. Meibomian gland functionality (number of MGYLS; primary outcome) and patient-reported subjective assessments (SPEED and OSDI questionnaires; secondary outcomes) were evaluated. Adverse events (AEs) and visual acuity were assessed as safety endpoints. Mean patient age was 41.7 years (n = 26; n = 13 per group). Mean ± SD number of MGYLS was not statistically significantly different between groups at baseline (combination treatment, 3.5 ± 1.5; warm compresses, 4.2 ± 1.4, P > 0.5), and was significantly greater with combination treatment versus warm compresses after 3 months of treatment (9.3 ± 2.7 vs. 4.7 ± 2.3; P = 0.006). Dry eye symptoms were significantly improved in both groups at all follow-up visits. Two AEs unrelated to treatment were reported; the BCVA was unchanged from baseline in both groups. The combination treatment regimen resulted in significant improvement in meibomian gland functionality and dry eye symptoms. No safety issues were observed.
Roles of TRPV1 and TRPA1 in Spontaneous Pain from Inflamed Masseter Muscle.
Wang, Sheng; Brigoli, Benjamin; Lim, Jongseuk; Karley, Alisha; Chung, Man-Kyo
2018-06-08
Craniofacial muscle pain, such as spontaneous pain and bite-evoked pain, are major symptoms in patients with temporomandibular disorders and infection. However, the underlying mechanisms of muscle pain, especially mechanisms of highly prevalent spontaneous pain, are poorly understood. Recently, we reported that transient receptor potential vanilloid 1 (TRPV1) contributes to spontaneous pain but only marginally contributes to bite-evoked pain during masseter inflammation. Here, we investigated the role of transient receptor potential ankyrin 1 (TRPA1) in spontaneous and bite-evoked pain during masseter inflammation, and dissected the relative contributions of TRPA1 and TRPV1. Masseter inflammation increased mouse grimace scale (MGS) scores and face wiping behaviors. Pharmacological or genetic inhibition of TRPA1 significantly attenuated MGS but not face wiping behaviors. MGS scores were also attenuated by scavenging putative endogenous ligands for TRPV1 or TRPA1. Simultaneous inhibition of TRPA1 by AP18 and TRPV1 by AMG9810 in masseter muscle resulted in robust inhibition of both MGS and face wiping behaviors. Administration of AP18 or AMG9810 to masseter muscle induced conditioned place preference (CPP). The extent of CPP following simultaneous administration of AP18 and AMG9810 was greater than that induced by the individual antagonists. In contrast, inflammation-induced reduction of bite force was not affected by the inhibition of TRPA1 alone or in combination with TRPV1. These results suggest that simultaneous inhibition of TRPV1 and TRPA1 produces additive relief of spontaneous pain, but does not ameliorate bite-evoked pain during masseter inflammation. Our results provide further evidence that distinct mechanisms underlie spontaneous and bite-evoked pain from inflamed masseter muscle. Copyright © 2018. Published by Elsevier Ltd.
Tu, Zhi-bin; Cui, Meng-jing; Yao, Hong-yan; Hu, Guo-qing; Xiang, Hui-yun; Stallones, Lorann; Zhang, Xu-jun
2012-04-01
To explore the risk factors on cases regarding work-related acute pesticide poisoning among farmers of Jiangsu province. A population-based, 1:2 matched case-control study was carried out, with 121 patients as case-group paired by 242 persons with same gender, district and age less then difference of 3 years, as controls. Cases were the ones who had suffered from work-related acute pesticide poisoning. A unified questionnaire was used. Data base was established by EpiData 3.1, and SPSS 16.0 was used for both data single factor and multi-conditional logistics regression analysis. Results from the single factor logistic regression analysis showed that the related risk factors were: lack of safety guidance, lack of readable labels before praying pesticides, no regression during application, using hand to wipe sweat, using leaking knapsack, body contaminated during application and continuing to work when feeling ill after the contact of pesticides. Results from multi-conditional logistic regression analysis indicated that the lack of safety guidance (OR=2.25, 95%CI: 1.35-3.74), no readable labels before praying pesticides (OR=1.95, 95%CI: 1.19-3.18), wiping the sweat by hand during application (OR=1.97, 95%CI: 1.20-3.24) and using leaking knapsack during application (OR=1.82, 95%CI:1.10-3.01) were risk factors for the occurrence of work-related acute pesticide poisoning. The lack of safety guidance, no readable labels before praying pesticides, wiping the sweat by hand or using leaking knapsack during application were correlated to the occurrence of work-related acute pesticide poisoning.
Madsen, Elainie Alenkær; Persson, Tomas; Sayehli, Susan; Lenninger, Sara; Sonesson, Göran
2013-01-01
Contagious yawning has been reported for humans, dogs and several non-human primate species, and associated with empathy in humans and other primates. Still, the function, development and underlying mechanisms of contagious yawning remain unclear. Humans and dogs show a developmental increase in susceptibility to yawn contagion, with children showing an increase around the age of four, when also empathy-related behaviours and accurate identification of others’ emotions begin to clearly evince. Explicit tests of yawn contagion in non-human apes have only involved adult individuals and examined the existence of conspecific yawn contagion. Here we report the first study of heterospecific contagious yawning in primates, and the ontogeny of susceptibility thereto in chimpanzees, Pan troglodytes verus. We examined whether emotional closeness, defined as attachment history with the yawning model, affected the strength of contagion, and compared the contagiousness of yawning to nose-wiping. Thirty-three orphaned chimpanzees observed an unfamiliar and familiar human (their surrogate human mother) yawn, gape and nose-wipe. Yawning, but not nose-wiping, was contagious for juvenile chimpanzees, while infants were immune to contagion. Like humans and dogs, chimpanzees are subject to a developmental trend in susceptibility to contagious yawning, and respond to heterospecific yawn stimuli. Emotional closeness with the model did not affect contagion. The familiarity-biased social modulatory effect on yawn contagion previously found among some adult primates, seem to only emerge later in development, or be limited to interactions with conspecifics. The influence of the ‘chameleon effect’, targeted vs. generalised empathy, perspective-taking and visual attention on contagious yawning is discussed. PMID:24146848
Todd, Ewen C D; Michaels, Barry S; Holah, John; Smith, Debra; Greig, Judy D; Bartleson, Charles A
2010-11-01
Alcohol compounds are increasingly used as a substitute for hand washing in health care environments and some public places because these compounds are easy to use and do not require water or hand drying materials. However, the effectiveness of these compounds depends on how much soil (bioburden) is present on the hands. Workers in health care environments and other public places must wash their hands before using antiseptics and/or wearing gloves. However, alcohol-based antiseptics, also called rubs and sanitizers, can be very effective for rapidly destroying some pathogens by the action of the aqueous alcohol solution without the need for water or drying with towels. Alcohol-based compounds seem to be the most effective treatment against gram-negative bacteria on lightly soiled hands, but antimicrobial soaps are as good or better when hands are more heavily contaminated. Instant sanitizers have no residual effect, unlike some antimicrobial soaps that retain antimicrobial activity after the hygienic action has been completed, e.g., after hand washing. Many alcohol-based hand rubs have antimicrobial agents added to them, but each formulation must be evaluated against the target pathogens in the environment of concern before being considered for use. Wipes also are widely used for quick cleanups of hands, other body parts, and surfaces. These wipes often contain alcohol and/or antimicrobial compounds and are used for personal hygiene where water is limited. However, antiseptics and wipes are not panaceas for every situation and are less effective in the presence of more than a light soil load and against most enteric viruses.
Cloth-covered chiropractic treatment tables as a source of allergens and pathogenic microbes☆
Evans, Marion W.; Campbell, Alan; Husbands, Chris; Breshears, Jennell; Ndetan, Harrison; Rupert, Ronald
2008-01-01
Abstract Objective Vinyl chiropractic tables have been found to harbor pathogenic bacteria, but wiping with a simple disinfection agent can significantly reduce the risk of bacteria. The aim of this study was to assess the presence of microbes and other allergens or pathogens on cloth chiropractic tables. Methods Cloth-covered tables in a chiropractic college teaching clinic were selected. Samples were taken from the facial piece and hand rests with RODAC plates containing nutrient agar, followed by confirmatory testing when indicated. Results Numerous microbacteria strains were found, including Staphylococcus aureus and Propionibacterium. Allergen-producing molds, including Candida, were also found. Conclusion Cloth tables were shown to contain pathogenic microbacteria and allergens. The chiropractic profession should establish an infection control protocol relevant to treatment tables and discard use of cloth-covered treatment tables in this process. PMID:19674718
DOE Office of Scientific and Technical Information (OSTI.GOV)
King, David A.
2013-12-12
The U.S. Department of Energy (DOE) Oak Ridge Office of Environmental Management (OR-EM) requested that Oak Ridge Associated Universities (ORAU), working under the Oak Ridge Institute for Science and Education (ORISE) contract, provide technical and independent waste management planning support using American Recovery and Reinvestment Act (ARRA) funds. Specifically, DOE OR-EM requested that ORAU plan and implement a sampling and analysis campaign targeting potential removable radiological contamination that may be transferrable to future personal protective equipment (PPE) and contamination control materials—collectively referred to as PPE throughout the remainder of this report—used in certain URS|CH2M Oak Ridge, LLC (UCOR) Surveillance andmore » Maintenance (S&M) Project facilities at the Oak Ridge National Laboratory (ORNL). Routine surveys in Bldgs. 3001, 3005, 3010, 3028, 3029, 3038, 3042, 3517, 4507, and 7500 continuously generate PPE. The waste is comprised of Tyvek coveralls, gloves, booties, Herculite, and other materials used to prevent worker exposure or the spread of contamination during routine maintenance and monitoring activities. This report describes the effort to collect and quantify removable activity that may be used by the ORNL S&M Project team to develop radiation instrumentation “screening criteria.” Material potentially containing removable activity was collected on smears, including both masselin large-area wipes (LAWs) and standard paper smears, and analyzed for site-related constituents (SRCs) in an analytical laboratory. The screening criteria, if approved, may be used to expedite waste disposition of relatively clean PPE. The ultimate objectives of this effort were to: 1) determine whether screening criteria can be developed for these facilities, and 2) provide process knowledge information for future site planners. The screening criteria, if calculated, must be formally approved by Federal Facility Agreement parties prior to use for ORNL S&M Project PPE disposal at the Environmental Management Waste Management Facility (EMWMF). ORAU executed the approved sampling and analysis plan (SAP) (DOE 2013) while closely coordinating with ORNL S&M Project personnel and using guidelines outlined in the Waste Handling Plan for Surveillance and Maintenance Activities at the Oak Ridge National Laboratory, DOE/OR/01-2565&D2 (WHP) (DOE 2012). WHP guidelines were followed because the PPE waste targeted by this SAP is consistent with that addressed under the approved Waste Lot (WL) 108.1 profile for disposal at EMWMF—this PPE is a “future waste stream” as defined in the WHP. The SAP presents sampling strategy and methodology, sample selection guidelines, and analytical guidelines and requirements necessary for characterizing future ORNL S&M Project PPE waste. This report presents a review of the sample and analysis methods including data quality objectives (DQOs), required deviations from the original design, summary of field activities, radiation measurement data, analytical laboratory results, a brief presentation of results, and process knowledge summaries.« less
Improved Boat For Liquid-Phase Epitaxy
NASA Technical Reports Server (NTRS)
Connolly, John C.
1991-01-01
Liquid-phase epitaxial (LPE) growth boat redesigned. Still fabricated from ultra-high-purity graphite, but modified to permit easy disassembly and cleaning, along with improved wiping action for more complete removal of melt to reduce carry-over of gallium. Larger substrates and more uniform composition obtained.
DECONTAMINATION WIPES FOR FIRST RESPONDERS - PHASE I
The threat of chemical or biological (CB) attack is real, and there is a recognized need for improved technologies to better respond to these situations. During a CB emergency, first responder units are critical for handling the emergency, and then restoring the environment wh...
ETV works in partnership with recognized standards and testing organizations and stakeholder groups consisting of regulators, buyers, and vendor organizations, with the full participation of individual technology developers. The program evaluates the performance of innovative
ETV works in partnership with recognized standards and testing organizations and stakeholder groups consisting of regulators, buyers, and vendor organizations, with the full participation of individual technology developers. The program evaluates the performance of innovative
2014-01-01
Malaria is one of the most important tropical diseases that has caused devastation throughout the history of mankind. Malaria eradication programmes in the past have had many positive effects but failed to wipe out malaria from most tropical countries, including Sri Lanka. Encouraged by the impressive levels of reduction in malaria case numbers during the past decade, Sri Lanka has launched a programme to eliminate malaria by year 2014. This article reviews the historical milestones associated with the malaria eradication programme that failed subsequently and the events that led to the launch of the ongoing malaria elimination plans at national-level and its strategies that are operational across the entire country. The existing gaps in knowledge are also discussed together with the priority areas for research to fill in these gaps that are posing as challenges to the envisaged goal of wiping out malaria from this island nation. PMID:24548783
Image superresolution by midfrequency sparse representation and total variation regularization
NASA Astrophysics Data System (ADS)
Xu, Jian; Chang, Zhiguo; Fan, Jiulun; Zhao, Xiaoqiang; Wu, Xiaomin; Wang, Yanzi
2015-01-01
Machine learning has provided many good tools for superresolution, whereas existing methods still need to be improved in many aspects. On one hand, the memory and time cost should be reduced. On the other hand, the step edges of the results obtained by the existing methods are not clear enough. We do the following work. First, we propose a method to extract the midfrequency features for dictionary learning. This method brings the benefit of a reduction of the memory and time complexity without sacrificing the performance. Second, we propose a detailed wiping-off total variation (DWO-TV) regularization model to reconstruct the sharp step edges. This model adds a novel constraint on the downsampling version of the high-resolution image to wipe off the details and artifacts and sharpen the step edges. Finally, step edges produced by the DWO-TV regularization and the details provided by learning are fused. Experimental results show that the proposed method offers a desirable compromise between low time and memory cost and the reconstruction quality.
Open Loop Heat Pipe Radiator Having a Free-Piston for Wiping Condensed Working Fluid
NASA Technical Reports Server (NTRS)
Weinstein, Leonard M. (Inventor)
2015-01-01
An open loop heat pipe radiator comprises a radiator tube and a free-piston. The radiator tube has a first end, a second end, and a tube wall, and the tube wall has an inner surface and an outer surface. The free-piston is enclosed within the radiator tube and is capable of movement within the radiator tube between the first and second ends. The free-piston defines a first space between the free-piston, the first end, and the tube wall, and further defines a second space between the free-piston, the second end, and the tube wall. A gaseous-state working fluid, which was evaporated to remove waste heat, alternately enters the first and second spaces, and the free-piston wipes condensed working fluid from the inner surface of the tube wall as the free-piston alternately moves between the first and second ends. The condensed working fluid is then pumped back to the heat source.
Hazrati, Sadegh; Harrad, Stuart
2007-03-01
PUF disk passive air samplers are increasingly employed for monitoring of POPs in ambient air. In order to utilize them as quantitative sampling devices, a calibration experiment was conducted. Time integrated indoor air concentrations of PCBs and PBDEs were obtained from a low volume air sampler operated over a 50 d period alongside the PUF disk samplers in the same office microenvironment. Passive sampling rates for the fully-sheltered sampler design employed in our research were determined for the 51 PCB and 7 PBDE congeners detected in all calibration samples. These values varied from 0.57 to 1.55 m3 d(-1) for individual PCBs and from 1.1 to 1.9 m3 d(-1) for PBDEs. These values are appreciably lower than those reported elsewhere for different PUF disk sampler designs (e.g. partially sheltered) employed under different conditions (e.g. in outdoor air), and derived using different calibration experiment configurations. This suggests that sampling rates derived for a specific sampler configuration deployed under specific environmental conditions, should not be extrapolated to different sampler configurations. Furthermore, our observation of variable congener-specific sampling rates (consistent with other studies), implies that more research is required in order to understand fully the factors that influence sampling rates. Analysis of wipe samples taken from the inside of the sampler housing, revealed evidence that the housing surface scavenges particle bound PBDEs.
... or cream, use your fingers to spread a thin film of medication over the affected area. If you are using a pledget, remove it from the foil pouch and gently wipe the affected area. If you are using the glass bottle of solution, apply a thin layer to the affected area using the applicator ...
40 CFR 63.460 - Applicability and designation of source.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 18, material safety data sheets, or engineering calculations. Wipe cleaning activities, such as using... continuous web cleaning machine subject to this subpart shall achieve compliance with the provisions of this... products, solvent cleaning machines used in the manufacture of narrow tubing, and continuous web cleaning...
40 CFR 63.460 - Applicability and designation of source.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 18, material safety data sheets, or engineering calculations. Wipe cleaning activities, such as using... continuous web cleaning machine subject to this subpart shall achieve compliance with the provisions of this... products, solvent cleaning machines used in the manufacture of narrow tubing, and continuous web cleaning...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-14
..., Uniseve Corporation, Jacobs Engineering and Stafflogix Corporation, Everett, WA; Amended Certification... Services, Healthforce, UNISEVE Corporation and Jacobs Engineering, Everett, Washington. The workers are engaged in activities related to the production of tissue products (paper towels, toilet paper, wipes) and...
STEM Progress in Katrina's Wake
ERIC Educational Resources Information Center
Gonzales, Dana
2008-01-01
When Hurricane Katrina hit New Orleans in 2005, it caused a devastating impact on the Crescent City's public education system. The devastating storm and its aftermath completely wiped out the educational infrastructure of the New Orleans Public Schools, making one of the country's largest metropolitan school districts virtually disappear. Two…
AMERICAN HEALTHY HOMES SURVEY: A NATIONAL STUDY OF RESIDENTIAL PESTICIDES MEASURED FROM FLOOR WIPES
The US Environmental Protection Agency and the US Department of Housing and Urban Development conducted the American Healthy Homes Survey (AHHS) in 2006 to assess environmental concentrations of lead, allergens, mold, pesticides, and arsenic in and around U.S. residences.
Identification of sulfur-containing impurities in biodiesel produced from brown grease
USDA-ARS?s Scientific Manuscript database
Crude biodiesel (Fatty Acid Methyl Esters (FAME)) has been produced from brown grease lipids (BGLs) and subjected to purification by wiped film evaporation (WFE). FAME from waste grease usually contains higher concentrations of sulfur (S) than allowed to meet specified quality standards for biodies...
ETV works in partnership with recognized standards and testing organizations and stakeholder groups consisting of regulators, buyers, and vendor organizations, with the full participation of individual technology developers. The program evaluates the performance of innovative