Sample records for wire localisation post

  1. The disappearing clip: an unusual complication in MRI biopsy

    PubMed Central

    Bourke, Anita Geraldine; Peter, Prasant; Jose, Chaitra Lesli

    2014-01-01

    MRI-guided biopsies are being increasingly used for otherwise occult breast lesions. Clip migration has been reported however, to the best of our knowledge, there have been no documented cases of entire disappearance of a marker clip. Absence of the postbiopsy marker clip was noted when our patient returned for preoperative hook-wire localisation even though accurate clip placement had been confirmed on the post-MRI biopsy mammogram. PMID:25139917

  2. Radioguided localisation of impalpable breast lesions using 99m-Technetium macroaggregated albumin: Lessons learnt during introduction of a new technique to guide preoperative localisation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Landman, Joanne; Kulawansa, Sagarika; McCarthy, Michael

    2015-03-15

    Preoperative wire-guided localisation (WGL) of impalpable breast lesions is widely used but can be technically difficult. Risks include wire migration, inaccurate placement, and inadequate surgical margins. Research shows that radioguided occult lesion localisation (ROLL) is quicker, easier, and can improve surgical and cosmetic outcomes. An audited introduction of ROLL was conducted to validate the technique as a feasible alternative to WGL. Fifty patients with single impalpable lesions and biopsy proven malignancy or indeterminate histology underwent WGL followed by intralesional radiopharmaceutical injection of 99m-Technetium macroaggregated albumin. Postprocedural mammography was performed to demonstrate wire position, and scintigraphy to evaluate radiopharmaceutical migration. Lymphoscintigraphymore » and intraoperative sentinel node biopsy were performed if indicated, followed by lesion localisation and excision using a gamma probe. Specimen imaging was performed, with immediate reexcision for visibly inadequate margins. Accurate localisation was achieved in 86% of patients with ROLL compared to 72% with WGL. All lesions were successfully removed, with clear margins in 71.8% of malignant lesions. Reexcision and intraoperative sentinel node localisation rates were equivalent to preaudit figures for WGL. ROLL was easy to perform and problems were infrequent. Inaccurate radiopharmaceutical placement necessitating WGL occurred in four patients. Minor radiopharmaceutical migration was common, but precluded using ROLL in only two cases. ROLL is effective, simple, inexpensive, and easily learnt; however, preoperative confirmation of correct radiopharmaceutical placement using mammography and the gamma probe is important to help ensure successful lesion removal. Insertion of a backup hookwire is recommended during the initial introduction of ROLL.« less

  3. Intra-operative localisation of thoracic spine level: a simple "'K'-wire in pedicle" technique.

    PubMed

    Thambiraj, Sathya; Quraishi, Nasir A

    2012-05-01

    To describe a simple and reliable method of intra-operative localisation of thoracic spine in a single surgical setting. Intra-operative localisation of thoracic spine levels can be difficult due to anatomical constraints, such as scapular shadow, patient's size and poor bone quality. This is particularly true in cases of thoracic discectomies in which the vertebral bodies appear normal. There are several methods described in recent literature to address this. Many of them require a separate procedure which was performed often the previous day. We report a technique which addresses the issue of localising thoracic level intra-operatively. After induction of general anaesthesia, the patient was placed prone and the pedicle of interest was identified using fluoroscopy. A K-wire was then inserted percutaneously into this pedicle under image guidance [confirmed in the antero-posterior (AP) and lateral views]. The wire was then cut close to the skin after bending it. The patient was now positioned laterally and the intended procedure performed through an anterior trans-thoracic approach. The 'K' wire was removed at the end of the procedure. We routinely used this technique in all our thoracic discectomies (four cases in 2 years). There were no intra-operative complications. This method is simple, avoids the patient undergoing two procedures and requires no more ability than placing an implant in the pedicle under fluoroscopy. Placing the 'K' wire into a fixed point like the pedicle facilitates rapid intra-operative viewing of the level of interest and is removed easily at the conclusion of surgery.

  4. Corrosion of Nickel-Titanium Orthodontic Archwires in Saliva and Oral Probiotic Supplements

    PubMed Central

    Turco, Gianluca; Contardo, Luca; Serdarević, Nikolina Leona; Otmačić, Helena; Ćurković; Špalj, Stjepan

    2017-01-01

    Objectives The aim of the study was to examine how probiotic supplements affect the corrosion stability of orthodontic archwires made of nickel-titanium alloy (NiTi). Materials and Methods NiTi archwires (0.508x0.508 and having the length of 2.5 cm) were tested. The archwires (composition Ni=50.4%, Ti=49.6%) were uncoated, nitrified and rhodium coated. Surface microgeometry was observed by using scanning electron microscope and surface roughness was measured by profilometer through these variables: roughness average, maximum height and maximum roughness depth. Corrosion was examined by electrochemical method of cyclic polarisation. Results Rhodium coated alloy in saliva has significantly higher general corrosion in saliva than nitrified alloy and uncoated alloy, with large effect size (p=0.027; η2=0.700). In the presence of probiotics, the result was even more pronounced (p<0.001; η2=0.936). Probiotic supplement increases general and localised corrosion of rhodium coated archwire and slightly decreases general corrosion and increases localised corrosion in uncoated archwire, while in the case of nitrified archwire the probability of corrosion is very low. The differences in surface roughness between NiTi wires before corrosion are not significant. Exposure to saliva decreases roughness average in rhodium coated wire (p=0.015; η2=0.501). Media do not significantly influence surface microgeometry in nitrified and uncoated wires. Conclusion Probiotic supplement affects corrosion depending on the type of coating of the NiTi archwire. It increases general corrosion of rhodium coated wire and causes localised corrosion of uncoated and rhodium coated archwire. Probiotic supplement does not have greater influence on surface roughness compared to that of saliva. PMID:29872237

  5. Multi-functional laser fabrication of diamond (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Salter, Patrick S.; Booth, Martin J.

    2017-03-01

    Ultrafast laser fabrication enables micro-structuring of diamond in 3D with a range of functionality. An ultrashort pulsed beam focused beneath the diamond surface induces structural modifications which are highly localised in three dimensions. At high pulse energy, the laser breaks down the diamond lattice at focus to form a graphitic phase. We demonstrate high resolution analysis of the structural changes revealing the graphitic phase to be formed of small clusters ( 100 nm in size) of amorphous sp2 bonded carbon accompanied by localised cracking of the diamond. When the laser focus is traced through the diamond, continuous graphitic wires are created which are electrically conductive. We have used such wires to fabricate large-area 3D radiation sensors which have been employed for the detection of high energy protons. Such graphitic wires have an associated stress field and a related localised modulation of the refractive index. We have recently written combinations of graphitic tracks in diamond to engineer stress fields to give a desired refractive index distribution and form an optical waveguide. Type III waveguides are demonstrated that allow guiding of both polarization states. We also show that by reducing the laser pulse energy, it is possible to avoid complete breakdown of the diamond lattice and simply introduce an ensemble of vacancies within the focal volume. This can be used to create single coherent NV centres in diamond isolated in 3D. All these processes are improved by processing at high numerical aperture (NA), for which adaptive optics aberration correction is essential.

  6. Intraoperative Localisation of Impalpable Breast Lesions Utilising the ROLLIS Technique Following Peritumoral 99mTc-colloid Sentinel Node Lymphoscintigraphy.

    PubMed

    Hung, Te-Jui; Burrage, John; Bourke, Anita; Taylor, Donna

    2017-08-24

    Ultrasound or stereotactic guided hook-wire localisation has been the standard-of-care for the pre-surgical localisation of impalpable breast lesions, which account for approximately a third of all breast cancer. Radioguided occult lesion localisation using I-125 seeds (ROLLIS) is a relatively new technique for guiding surgical excision of impalpable breast lesions, and is a promising alternative to the traditional hook-wire method. When combined with Tc-99m labelled colloid for sentinel node mapping in clinically indicated cases, there has been uncertainty regarding whether the downscatter of Tc-99m into the I-125 energy spectrum could adversely affect the intra-operative detection of the I-125 seed, especially pertaining to a peritumoral injection. To evaluate the percentage contribution of downscattered activity from Tc-99m into the I-125 energy spectrum in simulated intra-operative resections of an I-125 seed following different sentinel node injection techniques. Two scenarios were simulated using breast phantoms with lean chicken breast. The first scenario, with a 2cm distance between the Tc-99m injection site and the I-125 seed, simulated a periareolar ipsiquadrant injection with the subdermal or intradermal technique. The second scenario simulated a peritumoral injection technique with the Tc-99m bolus and an I-125 seed at the same site. Count rates were acquired with a hand-held gamma probe, and the percentage contribution of downscattered Tc-99m gamma photons to the I-125 energy window was calculated. In scenarios one and two, downscattered Tc-99m activity contributed 0.5% and 33% respectively to the detected count rate in the I-125 energy window. In both scenarios, the I-125 seed was successfully localised and removed using the gamma probe. There is no significant contribution of downscattered activity associated with a peritumoral injection of Tc-99m to adversely affect the accurate intra-operative localisation of an I- 125 seed. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  7. Assessment of localisation to auditory stimulation in post-comatose states: use the patient’s own name

    PubMed Central

    2013-01-01

    Background At present, there is no consensus on how to clinically assess localisation to sound in patients recovering from coma. We here studied auditory localisation using the patient’s own name as compared to a meaningless sound (i.e., ringing bell). Methods Eighty-six post-comatose patients diagnosed with a vegetative state/unresponsive wakefulness syndrome or a minimally conscious state were prospectively included. Localisation of auditory stimulation (i.e., head or eyes orientation toward the sound) was assessed using the patient’s own name as compared to a ringing bell. Statistical analyses used binomial testing with bonferroni correction for multiple comparisons. Results 37 (43%) out of the 86 studied patients showed localisation to auditory stimulation. More patients (n=34, 40%) oriented the head or eyes to their own name as compared to sound (n=20, 23%; p<0.001). Conclusions When assessing auditory function in disorders of consciousness, using the patient’s own name is here shown to be more suitable to elicit a response as compared to neutral sound. PMID:23506054

  8. Localised task-dependent motor-unit recruitment in the masseter.

    PubMed

    Schindler, H J; Hellmann, D; Giannakopoulos, N N; Eiglsperger, U; van Dijk, J P; Lapatki, B G

    2014-07-01

    Localised motor-unit (MU) recruitment in the masseter was analysed in this study. We investigated whether differential activation behaviour, which has already been reported for distant masseter regions, can also be detected in small muscle subvolumes at the level of single MUs. Two bipolar fine-wire electrodes and an intra-oral 3D bite-force transmitter were used to record intra-muscular electromyograms (EMG) resulting from controlled bite-forces of 10 healthy human subjects (mean age 24.1 ± 1.2 years). Two-hundred and seventeen decomposed MUs were organised into localised MU task groups with different (P < 0.001) force-direction-specific behaviour. Proportions of MUs involved in one, two, three or four examined tasks were 46%, 31%, 18% and 5%, respectively. This study provides evidence of the ability of the neuromuscular system to modify the mechanical output of small masseter subvolumes by differential control of adjacent MUs belonging to distinct task groups. Localised differential activation behaviour of the masseter may be the crucial factor enabling highly flexible and efficient adjustment of the muscle activity in response to complex local biomechanical needs, for example, continually varying bite-forces during the demanding masticatory process. © 2014 John Wiley & Sons Ltd.

  9. Antipilferage Seal User’s Guide

    DTIC Science & Technology

    1997-10-01

    seal is properly installed, ensure that there is no free play between the seal body and the wire. Verify and record the serial number. During post...and Record - Once the seal is properly installed, ensure that there is no free play between the seal body and the wire. During post-mortem...seal is properly installed, ensure that there is no free play between the seal body and the wire. Verify and record the serial number. During post

  10. Blind-Side, High-Temperature Fastener Lock

    NASA Technical Reports Server (NTRS)

    Matza, E. C.; While, D. M.

    1985-01-01

    Formed-in-place staple provides positive mechanical lock. Post-supported, advanced carbon/carbon standoff panels, currently under consideration as alternate thermal protection system for Shuttle orbiter, locking feature applicable to temperatures of 1,600 degrees F (870 degrees C) and higher and employable after panel installed, resulting in blind application. Blind-side locking technique employs wire staple inserted into grooves in post, formed in place by ramped portion of post grooves. This splays out wire ends that move into castellated end of grommet, mechanically locking post and grommet against relative rotation. Splayed ends provide mechanical lock to prevent wire from falling out.

  11. Analysis of Mitochondrial haemoglobin in Parkinson's disease brain.

    PubMed

    Shephard, Freya; Greville-Heygate, Oliver; Liddell, Susan; Emes, Richard; Chakrabarti, Lisa

    2016-07-01

    Mitochondrial dysfunction is an early feature of neurodegeneration. We have shown there are mitochondrial haemoglobin changes with age and neurodegeneration. We hypothesised that altered physiological processes are associated with recruitment and localisation of haemoglobin to these organelles. To confirm a dynamic localisation of haemoglobin we exposed Drosophila melanogaster to cyclical hypoxia with recovery. With a single cycle of hypoxia and recovery we found a relative accumulation of haemoglobin in the mitochondria compared with the cytosol. An additional cycle of hypoxia and recovery led to a significant increase of mitochondrial haemoglobin (p<0.05). We quantified ratios of human mitochondrial haemoglobin in 30 Parkinson's and matched control human post-mortem brains. Relative mitochondrial/cytosolic quantities of haemoglobin were obtained for the cortical region, substantia nigra and cerebellum. In age matched post-mortem brain mitochondrial haemoglobin ratios change, decreasing with disease duration in female cerebellum samples (n=7). The change is less discernible in male cerebellum (n=18). In cerebellar mitochondria, haemoglobin localisation in males with long disease duration shifts from the intermembrane space to the outer membrane of the organelle. These new data illustrate dynamic localisation of mitochondrial haemoglobin within the cell. Mitochondrial haemoglobin should be considered in the context of gender differences characterised in Parkinson's disease. It has been postulated that cerebellar circuitry may be activated to play a protective role in individuals with Parkinson's. The changing localisation of intracellular haemoglobin in response to hypoxia presents a novel pathway to delineate the role of the cerebellum in Parkinson's disease. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  12. Allogeneic transplantation for multiple myeloma: late relapse may occur as localised lytic lesion/plasmacytoma despite ongoing molecular remission.

    PubMed

    Byrne, J L; Fairbairn, J; Davy, B; Carter, I G; Bessell, E M; Russell, N H

    2003-02-01

    Allogeneic SCT for myeloma may be curative for young patients, but its role remains controversial because of a reported high TRM in some series. Since 1991, we have performed 25 allografts for myeloma using fully matched sibling donors. Of the 18 evaluable patients, 13 achieved CR at a median time of 2.5 months post-transplant. The five patients who were not in CR when assessed at 3 months received a short course of alpha-interferon and four subsequently achieved CR with this approach at a median of 82 days. One patient who failed to respond to IFN went on to achieve CR after four doses of DLI therapy, thus giving an overall CR rate of 72%. Seven patients have relapsed at a median of 4.7 years post-transplant (range 1.38-7.7 years) including two patients who had received IFN therapy. In five of these cases, relapse has been as a localised area of bone disease or isolated plasmacytoma with no evidence of marrow involvement by trephine biopsy or molecular analysis. All patients with localised relapse were treated with local radiotherapy +/-DLI and four are currently disease free despite two patients having had further treatment for a second localised lesion. Six patients died of TRM (24%) and the OS at 8 years is currently 69% with an EFS of 26%. These results suggest that allogeneic SCT for myeloma can be carried out with an acceptable TRM and a high CR rate. However, late relapses as localised disease may be a frequent finding and may represent foci of myeloma not eradicated by the conditioning. The use of pretransplant MRI scanning and top-up radiotherapy to involved areas may be useful in preventing this type of relapse.

  13. MISSE-6 Post-Flight Examination, Disassembly and Analysis Results

    DTIC Science & Technology

    2010-12-21

    Wiring, QCM wiring, and Rotor/ Sensor wiring. The data wiring for the Boeing experiments including QCMs and Rotor/ Sensor were labeled, removed, and...for a QCM In addition, Q9 was properly wired into datalogger D8, and the rotor sensor was properly wired into datalogger D9. Datalogger D9 was a...Wiring. Appendix B – Time-Temperature Results from Thermal Sensors distributed on MISSE-6A and MISSE-6B Appendix C - Atomic Oxygen Calculation

  14. High Resolution Eddy-Current Wire Testing Based on a Gmr Sensor-Array

    NASA Astrophysics Data System (ADS)

    Kreutzbruck, Marc; Allweins, Kai; Strackbein, Chris; Bernau, Hendrick

    2009-03-01

    Increasing demands in materials quality and cost effectiveness have led to advanced standards in manufacturing technology. Especially when dealing with high quality standards in conjunction with high throughput quantitative NDE techniques are vital to provide reliable and fast quality control systems. In this work we illuminate a modern electromagnetic NDE approach using a small GMR sensor array for testing superconducting wires. Four GMR sensors are positioned around the wire. Each GMR sensor provides a field sensitivity of 200 pT/√Hz and a spatial resolution of about 100 μm. This enables us to detect under surface defects of 100 μm in size in a depth of 200 μm with a signal-to-noise ratio of better than 400. Surface defects could be detected with a SNR of up to 10,000. Besides this remarkably SNR the small extent of GMR sensors results in a spatial resolution which offers new visualisation techniques for defect localisation, defect characterization and tomography-like mapping techniques. We also report on inverse algorithms based on either a Finite Element Method or an analytical approach. These allow for accurate defect localization on the urn scale and an estimation of the defect size.

  15. What Happened and Why? Considering the Role of Truth and Memory in Peace Education Curricula

    ERIC Educational Resources Information Center

    Lauritzen, Solvor Mjøberg; Nodeland, Tuva Skjelbred

    2017-01-01

    This paper is an exploration of challenges arising in the interplay between a standardised peace education curriculum and a localised post-conflict setting. Drawing on interview data from two Kenyan schools, the paper explores the reception of peace education initiatives implemented in Kenya following the post-election violence of 2007/2008…

  16. Comparison of the time taken for localised breast surgery pre- and post-introduction of intra-operative digital specimen mammography.

    PubMed

    Carraro do Nascimento, Vinicius; Bourke, Anita G

    2018-02-01

    More than half of the patients with an impalpable malignant breast lesion have a mammographically detected and imaged-guided localisation, which can be technically challenging for the breast surgeon. Specimen imaging is used to confirm successful excision of the localised index lesion and has improved the operating list efficiency resulting in a higher number of excisions per surgical list. The aim of this study was to evaluate whether introducing IDSM (intra-operative digital specimen mammography) saved operation time for localised breast surgery. A single-centre retrospective review was undertaken to compare the operation time (from incision to wound closure) taken for excision of 114 consecutive image-guided localised impalpable breast lesions, performed using departmental specimen radiography (DSR), 6 months prior to the introduction of IDSM (Hologic, Trident ® ) in March 2013, with the theatre time taken for excision of 121 consecutive image-guided localised impalpable breast lesions in the 6 months following introduction of IDSM. There was no significant difference in mean surgical time, which were 47.8 (±27.3) minutes in the CSR group and 48.8 (±25.7) minutes in the IDSM group. We were expecting to confirm a reduction in theatre time with the introduction of IDSM. Surprisingly, no difference in operating times was demonstrated. Factors that influenced the impact of IDSM included the proximity of the imaging department to the operating theatre. © 2017 The Royal Australian and New Zealand College of Radiologists.

  17. Subcellular localisations of the CPTI collection of YFP-tagged proteins in Drosophila embryos

    PubMed Central

    Lye, Claire M.; Naylor, Huw W.; Sanson, Bénédicte

    2014-01-01

    A key challenge in the post-genomic area is to identify the function of the genes discovered, with many still uncharacterised in all metazoans. A first step is transcription pattern characterisation, for which we now have near whole-genome coverage in Drosophila. However, we have much more limited information about the expression and subcellular localisation of the corresponding proteins. The Cambridge Protein Trap Consortium generated, via piggyBac transposition, over 600 novel YFP-trap proteins tagging just under 400 Drosophila loci. Here, we characterise the subcellular localisations and expression patterns of these insertions, called the CPTI lines, in Drosophila embryos. We have systematically analysed subcellular localisations at cellularisation (stage 5) and recorded expression patterns at stage 5, at mid-embryogenesis (stage 11) and at late embryogenesis (stages 15-17). At stage 5, 31% of the nuclear lines (41) and 26% of the cytoplasmic lines (67) show discrete localisations that provide clues on the function of the protein and markers for organelles or regions, including nucleoli, the nuclear envelope, nuclear speckles, centrosomes, mitochondria, the endoplasmic reticulum, Golgi, lysosomes and peroxisomes. We characterised the membranous/cortical lines (102) throughout stage 5 to 10 during epithelial morphogenesis, documenting their apico-basal position and identifying those secreted in the extracellular space. We identified the tricellular vertices as a specialized membrane domain marked by the integral membrane protein Sidekick. Finally, we categorised the localisation of the membranous/cortical proteins during cytokinesis. PMID:25294944

  18. Application of wire beam electrode technique to investigate initiation and propagation of rebar corrosion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shi, Wei; Dong, Ze Hua, E-mail: zehua.dong@gmail.com; Kong, De Jie

    Multi-electrode technique named as wire beam electrode (WBE) was used to study pitting corrosion of rebar under concrete cover. When WBE embedded mortar sample was immersed in NaCl solution, uneven distributions of galvanic current and open circuit potential (OCP) on the WBE were observed due to the initiation of pitting corrosion. The following oxygen depletion in mortar facilitated the negative shift of the OCP and the smoothing of the current and potential distributions. Wetting–drying cycle experiments showed that corrosion products instead of oxygen in wet mortar specimen sustained the propagation of pitting corrosion due to Fe (III) taking part inmore » cathodic depolarization during oxygen-deficient wet period, which was confirmed by micro-Raman spectroscopy. In addition, new pitting corrosion occurred mainly near the corrosion products, leading to preferentially horizontal propagation of rust layer on the WBE. A localized corrosion factor was further presented to quantify the localised corrosion based on galvanic current maps.« less

  19. Diagnostic accuracy of 3T magnetic resonance imaging in the preoperative localisation of parathyroid adenomas: comparison with ultrasound and 99mTc-sestamibi scans.

    PubMed

    Argirò, Renato; Diacinti, Daniele; Sacconi, Beatrice; Iannarelli, Angelo; Diacinti, Davide; Cipriani, Cristiana; Pisani, Daniela; Romagnoli, Elisabetta; Biffoni, Marco; Di Gioia, Cira; Pepe, Jessica; Bezzi, Mario; Letizia, Claudio; Minisola, Salvatore; Catalano, Carlo

    2018-05-07

    To evaluate the diagnostic performance of 3TMRI in comparison with ultrasound (US) and 99mTc-sestamibi scan for presurgical localisation of parathyroid adenomas (PTAs) in patients with primary hyperparathyroidism (PHPT). Fifty-seven patients affected by PHPT were prospectively enrolled and underwent US, 99mTc-sestamibi and 3TMRI. T2-weighted and post-contrast T1-weighted Iterative decomposition of water and fat with Echo Asymmetry and Least squares estimation (IDEAL) sequences were acquired. Diagnostic performance of US, 99mTc-sestamibi and MRI in localising PTAs to correct quadrant were compared according to surgical and pathological findings. According to surgical findings, US correctly localised 41/46 PTAs (sensitivity of 89.1%; specificity 97.5%; PPV 93.1% and NPV 95.6%); 99mTc-sestamibi correctly localised 38/46 PTAs (sensitivity 83.6%, specificity 98.3%, PPV 95% and NPV 93.7%). US and 99mTc-sestamibi combined had a sensitivity of 93.4% (43/46 PTAs), specificity of 98.3%, PPV 95% and NPV 98.3%. MRI correctly localised 45/46 PTAs (sensitivity 97.8%; specificity 97.5%; PPV 93.7% and NPV 99.2%). MRI was able to detect six adenomas missed by 99mTc-sestamibi and two adenomas missed by US. MRI and US were able to detect all enlarged parathyroid glands in patients with multiglandular disease. MRI identified six of seven ectopic adenomas. Our study demonstrated high diagnostic performance of 3T MRI in the preoperative PTAs quadrant localisation, as well as in patients with multiglandular disease and ectopic PTAs. MRI may be preferred to adequately select patient candidates for minimally invasive parathyroidectomy (MIP). • PTA(s) quadrant localisation by 3TMRI was more accurate than US+99mTc-sestamibi. • MRI identified all enlarged glands in multiglandular disease similarly to US. • MRI identified 6/7 ectopic PTAs similarly to 99mTc-sestamibi. • Presurgical PTA(s) localisation by 3TMRI select the optimal candidates for MIP.

  20. Mapping of cingulate motor function by cortical stimulation.

    PubMed

    Basha, Maysaa M; Fernández-Baca Vaca, Guadalupe; Lüders, Hans O

    2013-09-01

    An 8-year-old boy with intractable left mesiofrontal lobe epilepsy underwent placement of stereotactic intracerebral depth electrodes to better localise the epileptogenic zone. Co-registration of preoperative MRI and post-electrode implantation CAT allowed for anatomical localisation of electrode contacts. Electrical stimulation of electrodes over the dorsal and ventral banks of the cingulate cortex on the left produced right foot dorsiflexion and right wrist and elbow flexion, respectively, demonstrating detailed representation of cingulate motor function in humans, somatotopically distributed along the banks of the cingulate sulcus, as seen in the non-human primate. [Published with video sequences].

  1. [Application of straight wire appliance for pre- and post-surgical orthodontics].

    PubMed

    Zhou, Yan-Heng; Sun, Yan-Nan; Hu, Wei; Fu, Min-Kui

    2004-11-01

    To analyze the surgical patients treated with straight wire appliance for guidelines of clinical using of the appliance. Totally 51 patients from Joint Clinic of Orthodontic Surgery, Peking University School of Stomatology with dentofacial deformities treated with straight wire appliance were analyzed. The patients were aged from 15 years to 34 years 5 months, average 18 years 9 months. Among whom, 16 are males, while the other 35 are females. Eighteen patients were treated with extraction of teeth, while other 33 cases were nonextraction case. The duration of average presurgical orthodontic treatment was 13.3 months, and 10.4 months was for postsurgical orthodontic treatment, totally active treatment time was 25.5 months. Straight wire appliance would benefit a lot for three dimensional control of teeth when doing pre- and post-surgical orthodontic treatment. Good results could be achieved without wire bending.

  2. Residues within the myristoylation motif determine intracellular targeting of the neuronal Ca2+ sensor protein KChIP1 to post-ER transport vesicles and traffic of Kv4 K+ channels.

    PubMed

    O'Callaghan, Dermott W; Hasdemir, Burcu; Leighton, Mark; Burgoyne, Robert D

    2003-12-01

    KChIPs (K+ channel interacting proteins) regulate the function of A-type Kv4 potassium channels by modifying channel properties and by increasing their cell surface expression. We have explored factors affecting the localisation of Kv4.2 and the targeting of KChIP1 and other NCS proteins by using GFP-variant fusion proteins expressed in HeLa cells. ECFP-Kv4.2 expressed alone was not retained in the ER but reached the Golgi complex. In cells co-expressing ECFP-Kv4.2 and KChIP1-EYFP, the two proteins were co-localised and were mainly present on the plasma membrane. When KChIP1-EYFP was expressed alone it was instead targeted to punctate structures. This was distinct from the localisation of the NCS proteins NCS-1 and hippocalcin, which were targeted to the trans-Golgi network (TGN) and plasma membrane. The membrane localisation of each NCS protein required myristoylation and minimal myristoylation motifs of hippocalcin or KChIP1 were sufficient to target fusion proteins to either TGN/plasma membrane or to punctate structures. The existence of targeting information within the N-terminal motifs was confirmed by mutagenesis of residues corresponding to three conserved basic amino acids in hippocalcin and NCS-1 at positions 3, 7 and 9. Residues at these positions determined intracellular targeting to the different organelles. Myristoylation and correct targeting of KChIP1 was required for the efficient traffic of ECFP-Kv4.2 to the plasma membrane. Expression of KChIP1(1-11)-EYFP resulted in the formation of enlarged structures that were positive for ERGIC-53 and beta-COP. ECFP-Kv4.2 was also accumulated in these structures suggesting that KChIP1(1-11)-EYFP inhibited traffic out of the ERGIC. We suggest that KChIP1 is targeted by its myristoylation motif to post-ER transport vesicles where it could interact with and regulate the traffic of Kv4 channels to the plasma membrane under the influence of localised Ca2+ signals.

  3. Hybrid SPECT-CT and PET-CT imaging of differentiated thyroid carcinoma.

    PubMed

    Wong, K K; Zarzhevsky, N; Cahill, J M; Frey, K A; Avram, A M

    2009-10-01

    Hybrid imaging modalities such as radioiodine single photon emission CT with integrated CT ((131)I SPECT-CT) and 2-(fluorine-18)-fluoro-2-deoxy-D-glucose positron emission tomography with integrated CT (FDG PET-CT) allow the rapid and efficient fusion of functional and anatomic images, and provide diagnostic information that may influence management decisions in patients with differentiated thyroid carcinoma (DTC). Diagnostic localisation and therapy of these tumours are dependent upon their capacity to concentrate radioiodine ((131)I) via uptake through the sodium-iodide symporter and retention within the tumour. The prognosis for most patients with DTC is favourable, although controversy exists regarding the role of post-operative (131)I therapy in patients at low-risk for disease. Accurate identification of functional thyroid tissue (benign or malignant) using diagnostic (131)I planar scintigraphy complemented by SPECT-CT imaging enables the completion of post-operative staging and patient risk stratification prior to (131)I therapy administration. In patients with non-iodine-avid tumours (negative (131)I scan but elevated thyroglobulin indicative of persistent or recurrent disease), FDG PET-CT is used to identify tumours with enhanced glucose metabolism and to localise the source of thyroglobulin production. The CT component of this hybrid technology provides anatomic localisation of activity and allows CT-based attenuation correction of PET images. Images from 15 patients illustrate the applications of (131)I SPECT-CT and FDG PET-CT.

  4. Intracellular localisation of dengue-2 RNA in mosquito cell culture using electron microscopic in situ hybridisation.

    PubMed

    Grief, C; Galler, R; Côrtes, L M; Barth, O M

    1997-01-01

    Non-isotopic in situ hybridisation was used at the electron microscope level to determine the localisation of viral RNA in dengue-2 infected mosquito cells at 14, 24, 48 and 72 h post-infection. In situ hybridisation was carried out on sections of dengue-2 infected mosquito cells using a digoxigenin-labelled DNA probe to the envelope protein gene sequence of the virus. Viral RNA was consistently localised over the rough endoplasmic reticulum and the virus-induced smooth membrane structures which form within the endoplasmic reticulum. During the later stages of infection electron-dense areas were observed to develop in close proximity to the smooth membrane structures. Electron microscopic in situ hybridisation showed that these denser areas contained both viral RNA and virus particles. Our results show that in dengue-2 infected mosquito cells the smooth membrane structures are an important site for the concentration of dengue viral RNA and its possible subsequent encapsidation into virus particles.

  5. 3D Image Fusion to Localise Intercostal Arteries During TEVAR.

    PubMed

    Koutouzi, G; Sandström, C; Skoog, P; Roos, H; Falkenberg, M

    2017-01-01

    Preservation of intercostal arteries during thoracic aortic procedures reduces the risk of post-operative paraparesis. The origins of the intercostal arteries are visible on pre-operative computed tomography angiography (CTA), but rarely on intra-operative angiography. The purpose of this report is to suggest an image fusion technique for intra-operative localisation of the intercostal arteries during thoracic endovascular repair (TEVAR). The ostia of the intercostal arteries are identified and manually marked with rings on the pre-operative CTA. The optimal distal landing site in the descending aorta is determined and marked, allowing enough length for an adequate seal and attachment without covering more intercostal arteries than necessary. After 3D/3D fusion of the pre-operative CTA with an intra-operative cone-beam CT (CBCT), the markings are overlaid on the live fluoroscopy screen for guidance. The accuracy of the overlay is confirmed with digital subtraction angiography (DSA) and the overlay is adjusted when needed. Stent graft deployment is guided by the markings. The initial experience of this technique in seven patients is presented. 3D image fusion was feasible in all cases. Follow-up CTA after 1 month revealed that all intercostal arteries planned for preservation, were patent. None of the patients developed signs of spinal cord ischaemia. 3D image fusion can be used to localise the intercostal arteries during TEVAR. This may preserve some intercostal arteries and reduce the risk of post-operative spinal cord ischaemia.

  6. In Situ Electrochemical Deposition of Microscopic Wires

    NASA Technical Reports Server (NTRS)

    Yun, Minhee; Myung, Nosang; Vasquez, Richard

    2005-01-01

    A method of fabrication of wires having micron and submicron dimensions is built around electrochemical deposition of the wires in their final positions between electrodes in integrated circuits or other devices in which the wires are to be used. Heretofore, nanowires have been fabricated by a variety of techniques characterized by low degrees of controllability and low throughput rates, and it has been necessary to align and electrically connect the wires in their final positions by use of sophisticated equipment in expensive and tedious post-growth assembly processes. The present method is more economical, offers higher yields, enables control of wire widths, and eliminates the need for post-growth assembly. The wires fabricated by this method could be used as simple electrical conductors or as transducers in sensors. Depending upon electrodeposition conditions and the compositions of the electroplating solutions in specific applications, the wires could be made of metals, alloys, metal oxides, semiconductors, or electrically conductive polymers. In this method, one uses fabrication processes that are standard in the semiconductor industry. These include cleaning, dry etching, low-pressure chemical vapor deposition, lithography, dielectric deposition, electron-beam lithography, and metallization processes as well as the electrochemical deposition process used to form the wires. In a typical case of fabrication of a circuit that includes electrodes between which microscopic wires are to be formed on a silicon substrate, the fabrication processes follow a standard sequence until just before the fabrication of the microscopic wires. Then, by use of a thermal SiO-deposition technique, the electrodes and the substrate surface areas in the gaps between them are covered with SiO. Next, the SiO is electron-beam patterned, then reactive-ion etched to form channels having specified widths (typically about 1 m or less) that define the widths of the wires to be formed. Drops of an electroplating solution are placed on the substrate in the regions containing the channels thus formed, then the wires are electrodeposited from the solution onto the exposed portions of the electrodes and into the channels. The electrodeposition is a room-temperature, atmospheric-pressure process. The figure shows an example of palladium wires that were electrodeposited into 1-mm-wide channels between gold electrodes.

  7. Delamination of Pearlitic Steel Wires: The Defining Role of Prior-Drawing Microstructure

    NASA Astrophysics Data System (ADS)

    Durgaprasad, A.; Giri, S.; Lenka, S.; Sarkar, Sudip Kumar; Biswas, Aniruddha; Kundu, S.; Mishra, S.; Chandra, S.; Doherty, R. D.; Samajdar, I.

    2018-06-01

    This article reports the occasional (< 10 pct of the actual production) delamination of pearlitic wires subjected to a drawing strain of 2.5. The original wire rods which exhibited post-drawing delamination had noticeably lower axial alignment of the pearlite: 22 ± 5 pct vs 34 ± 4 pct in the nondelaminated wires. Although all wires had similar through-thickness texture and stress gradients, delaminated wires had stronger gradients in composition and higher hardness across the ferrite-cementite interface. Carbide dissolution and formation of supersaturated ferrite were clearly correlated with delamination, which could be effectively mitigated by controlled laboratory annealing at 673 K. Direct observations on samples subjected to simple shear revealed significant differences in shear localizations. These were controlled by pearlite morphology and interlamellar spacing. Prior-drawing microstructure of coarse misaligned pearlite thus emerged as a critical factor in the wire drawing-induced delamination of the pearlitic wires.

  8. Corrosion Induced Loss of Capacity of Post Tensioned Seven Wire Strand Cable Used in Multistrand Anchor Systems Installed at Corps Projects

    DTIC Science & Technology

    2016-12-01

    Universal Test Machine. .................. 7 Figure 2.2. Pull-test results of PT seven-wire strand cable surrounded by a quickset, steel - reinforced epoxy...13 Figure 2.7. Pull-test results of PT seven-wire strand cable surrounded by a quickset, steel - reinforced...surrounded by a thick layer of quickset, steel -reinforced epoxy and with 40% reduced wedges. ....................................................... 15

  9. Cyclic and low temperature effects on microcircuits

    NASA Technical Reports Server (NTRS)

    Weissflug, V. A.; Sisul, E. V.

    1977-01-01

    Cyclic temperature and low temperature operating life tests, and pre-/post-life device evaluations were used to determine the degrading effects of thermal environments on microcircuit reliability. Low power transistor-transistor-logic gates and linear devices were included in each test group. Device metallization systems included aluminum metallization/aluminum wire, aluminum metallization/gold wire, and gold metallization/gold wire. Fewer than 2% electrical failures were observed during the cyclic and low temperature life tests and the post-life evaluations revealed approximately 2% bond pull failures. Reconstruction of aluminum die metallization was observed in all devices and the severity of the reconstruction appeared to be directly related to the magnitude of the temperature excursion. All types of bonds except the gold/gold bonds were weakened by exposure to repeated cyclic temperature stress.

  10. Detail of 94' lowband reflector screen posts, note the concrete ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Detail of 94' low-band reflector screen posts, note the concrete curb and vertical wires between posts, view facing north northeast - U.S. Naval Base, Pearl Harbor, Naval Radio Station, AF/FRD-10 Circularly Disposed Antenna Array, Wahiawa, Honolulu County, HI

  11. Glass fiber reinforced composite resin as an intracanal post--a clinical study.

    PubMed

    Subramaniam, Priya; Babu, K L Girish; Sunny, Raju

    2008-01-01

    Restoration of primary incisors, which have been severely damaged by early childhood caries or trauma, is a difficult task for the pediatric dentist. With the introduction of new adhesive systems and restorative materials, alternative approaches for treating these teeth have been proposed. Ten healthy children aged between 3-4 years who had 28 grossly destructed primary maxillary incisors requiring intra canal retention were selected for the study. Following root canal treatment, either a Glass Fiber Reinforced Composite Resin (GFRCR everStick,, Finland) or an omega shaped stainless steel wire were placed as intracanal posts in these teeth. Flowable composite was used for cementation of posts and also to build up the coronal structure using celluloid strip crowns. Both types of intracanal posts were evaluated for retention and marginal adaptation at 1, 6 and 12 months. The data obtained was subjected to statistical analysis. GFRCR intracanal posts showed better retention and marginal adaptation than omega shaped stainless steel wire posts.

  12. Radiographic comparison of apical root resorption after orthodontic treatment between bidimensional and Roth straight-wire techniques

    PubMed Central

    Zawawi, Khalid H; Malki, Ghadah A

    2014-01-01

    Objective: The aim of this study was to compare the amount of root resorption after orthodontic treatment between the bidimensional and the Roth straight-wire techniques. Another objective was to compare the amount of root resorption in the whole sample studied and record the prevalence of root resorption. Materials and Methods: The sample consisted of 40 patients (age ranged between 11 and 18 years) with Angle Class II division 1 malocclusions, treated nonextraction. Twenty patients were treated with bidimensional technique and 20 with a 0.018-inch Roth straight-wire technique. Root lengths of the maxillary incisors were measured on pre- and post-treatment periapical radiographs. Results: The results demonstrated that the bidimensional and Roth straight-wire groups showed significant root resorption after treatment, 1.11 (0.17) and 0.86 (0.05), respectively, P < 0.001. When comparing the amount of root shortening between the bidimensional and Roth straight-wire groups, there was no significant difference between the mean change from pre- to post-treatment between bidimensional group (mean = 1.00 ± 1.34) and Roth straight-wire group (mean = 0.88 ± 0.86), P = 0.63. Considering the whole sample, there was no root resoprtion in 32.5% of the analysed teeth. There was only mild resorption in 56.2%, moderate in 8.8% and severe in only 2.5% of the teeth. Conclusions: Treatment with the bidimensional technique did not produce an increase in the amount of root resorption. The prevalence and amount of root resorption was similar between bidimensional and Roth straight-wire techniques. PMID:25426453

  13. Radiographic comparison of apical root resorption after orthodontic treatment between bidimensional and Roth straight-wire techniques.

    PubMed

    Zawawi, Khalid H; Malki, Ghadah A

    2014-10-01

    The aim of this study was to compare the amount of root resorption after orthodontic treatment between the bidimensional and the Roth straight-wire techniques. Another objective was to compare the amount of root resorption in the whole sample studied and record the prevalence of root resorption. The sample consisted of 40 patients (age ranged between 11 and 18 years) with Angle Class II division 1 malocclusions, treated nonextraction. Twenty patients were treated with bidimensional technique and 20 with a 0.018-inch Roth straight-wire technique. Root lengths of the maxillary incisors were measured on pre- and post-treatment periapical radiographs. The results demonstrated that the bidimensional and Roth straight-wire groups showed significant root resorption after treatment, 1.11 (0.17) and 0.86 (0.05), respectively, P < 0.001. When comparing the amount of root shortening between the bidimensional and Roth straight-wire groups, there was no significant difference between the mean change from pre- to post-treatment between bidimensional group (mean = 1.00 ± 1.34) and Roth straight-wire group (mean = 0.88 ± 0.86), P = 0.63. Considering the whole sample, there was no root resoprtion in 32.5% of the analysed teeth. There was only mild resorption in 56.2%, moderate in 8.8% and severe in only 2.5% of the teeth. Treatment with the bidimensional technique did not produce an increase in the amount of root resorption. The prevalence and amount of root resorption was similar between bidimensional and Roth straight-wire techniques.

  14. 75 FR 28557 - Pre-Stressed Concrete Steel Wire Strand from the People's Republic of China: Final Affirmative...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-21

    ...-stressed concrete (both pre-tensioned and post- tensioned) applications. The scope of this investigation... DEPARTMENT OF COMMERCE International Trade Administration [C-570-946] Pre-Stressed Concrete Steel... producers and exporters of pre-stressed concrete steel wire strand from the People's Republic of China (the...

  15. Horizontal transmission of Salmonella and Campylobacter among caged and cage-free laying hens

    USDA-ARS?s Scientific Manuscript database

    In each of five trials, laying hens (56-72 wk-of-age) were challenged orally, intracolonally, and intravaginally with Salmonella and Campylobacter. One wk post inoculation, challenged hens (n=3) were commingled with non-challenged hens (n=12) in conventional wire cages, on all wire slats, or on all...

  16. Electromechanical properties of superconducting MgB2 wire

    NASA Astrophysics Data System (ADS)

    Salama, K.; Zhou, Y. X.; Hanna, M.; Alessandrini, M.; Putman, P. T.; Fang, H.

    2005-12-01

    The current-carrying capability of superconducting wires is degraded by stress. Therefore electromechanical properties are one of the key feedback parameters needed for progress in conductor applications. In this work, uniaxial tensile stresses and bending stresses were applied to Fe /MgB2 wires at room temperature, followed by measurement of critical current using a transport method at 4.2 K. Basic mechanical properties were calculated from the measured stress-strain characteristics. The irreversible tensile strain at which the critical current density of MgB2 wire starts to degrade was found to be 0.5%. In addition, the degradation of Ic with decreasing bending diameters was found to be very rapid for wires that were deformed after the heat treatment that forms the MgB2 compound, while not much degradation of Ic was found for wires that were bent before being annealed. SEM observations confirmed that cracks could be healed by post-annealing.

  17. [New developments in the application of resorbable implants].

    PubMed

    Rehm, K E; Helling, H J; Gatzka, C

    1997-05-01

    The application of biodegradable implants is combined with advantages and disadvantages. They offer a great deal of innovative ideas. Best evaluation has been done with pins for the fixation of low loaded osteochondral fractures. When using 2.7 mm Polypin primary mechanical stability of distal radius fractures is comparable with the fixation by 1.8 mm K-wires. A prospective and randomised study with two years follow up, including 183 radial head fractures, showed no significant difference in results and complications in metal and polyactide implants. For this localisation and other comparable indications the implant can be recommended. Despite the more extensive degradable device overall costs can be reduced with the polymer implant. Orientruded polyactide screws showed good clinical results, newetheless resorption was extremely late within 5 to 7 years.

  18. Effects of stoichiometry, purity, etching and distilling on resistance of MgB 2 pellets and wire segments

    NASA Astrophysics Data System (ADS)

    Ribeiro, R. A.; Bud'ko, S. L.; Petrovic, C.; Canfield, P. C.

    2002-11-01

    We present a study of the effects of non-stoichiometry, boron purity, wire diameter and post-synthesis treatment (etching and Mg distilling) on the temperature dependent resistance and resistivity of sintered MgB 2 pellets and wire segments. Whereas the residual resistivity ratio (RRR) varies between RRR≈4 to RRR⩾20 for different boron purity, it is only moderately affected by non-stoichiometry (from 20% Mg deficiency to 20% Mg excess) and is apparently independent of wire diameter and presence of Mg metal traces on the wire surface. The obtained set of data indicates that RRR values in excess of 20 and residual resistivities as low as ρ 0≈0.4 μΩ cm are intrinsic material properties of high purity MgB 2.

  19. Estimation of changes in nickel and chromium content in nickel-titanium and stainless steel orthodontic wires used during orthodontic treatment: An analytical and scanning electron microscopic study.

    PubMed

    Kararia, Vandana; Jain, Pradeep; Chaudhary, Seema; Kararia, Nitin

    2015-01-01

    The biocompatibility of orthodontic dental alloys has been investigated over the past 20 years, but the results have been inconclusive. The study compares standard 3 M Unitek nickel-titanium (NiTi) and stainless steel archwires with locally available JJ orthodontics wires. Scanning electron microscope (SEM) study of surface changes and complexometric titration to study compositional change was performed. Ten archwires each of group 1-3 M 0.016" NiTi, group 2-JJ 0.016" NiTi, group 3-3 M 0.019" *0.025" SS and group 4-JJ SS contributed a 10 mm piece of wire for analysis prior to insertion in the patient and 6 weeks post insertion. SEM images were recorded at ×2000, ×4000 and ×6000 magnification. The same samples were subjected to complexiometric titration using ethylenediaminetetraacetic acid to gauge the actual change in the composition. The SEM images of all the archwires showed marked changes with deep scratches and grooves and dark pitting corrosion areas post intraoral use. 3M wires showed an uniform criss-cross pattern in as received wires indicating a coating which was absent after intraoral use. There was a significant release of Nickel and Chromium from both group 3 and 4. Group 2 wires released ions significantly more than group 1 (P = 0.0). Extensive and stringent trials are required before certifying any product to be used in Orthodontics.

  20. A biomechanical comparison of three sternotomy closure techniques.

    PubMed

    Cohen, David J; Griffin, Lanny V

    2002-02-01

    A biomechanical study of three sternotomy closure techniques (figure-of-eight stainless-steel wires, Pectofix Dynamic Sternal Fixation [DSF] stainless-steel plates, and figure-of-eight stainless-steel cables) was conducted to compare strength and stiffness variables in three clinically relevant loading modes (anterior-posterior shear, longitudinal shear, and lateral distraction). All tests were conducted on polyurethane foam sternal models that simulate the properties of cancellous bone. Each model was divided longitudinally and reconstructed using one of the sternotomy closure repair techniques. Tests were performed using a materials testing system that applies a continuously increasing amount of force in one direction to the model until it catastrophically breaks. A total of six trials of each fixation type in each of three test groups were prepared and tested, for a total of 54 tests. Strength and stiffness variables as well as a post-yield analysis of failure were evaluated. Sternums repaired using the DSF plate system are a more rigid construct than sternums repaired using the stainless-steel wires or cables in the distraction and transverse shear modes and they are not significantly different from sternums repaired with wires or cables in the longitudinal shear mode. The DSF plate system offers a 25% improvement in resistance to failure (yield) compared to wires when a transverse shear force is applied to the model. The cable system had a higher resistance to failure than the wires in all modes although the differences were not statistically significant. Additionally, the DSF plate system provides substantial reduction of the implant's cutting into the sternal model under loading as evidenced by the post-yield displacement when compared with either cables or wires for the distraction and longitudinal shear modes. For the transverse shear mode, the cables or wires would completely fail at the load for which cutting begins for the DSF. Both the DSF plate system and the stainless-steel cable system offer important advantages over figure-of-eight wire for sternal closure.

  1. A Case Study on the Failure on Apollo 13

    NASA Technical Reports Server (NTRS)

    Anderson, Brenda Lindley

    2011-01-01

    Summary of Findings: (1) The post-failure investigation determined that extended operation of the heater damaged the wiring inside O2 #2. (2) Apparently during other stir operations prior to the explosion, the damaged wires didn't come in contact enough to spark. The right conditions had to be in position to cause the arcing which led to the blast.

  2. Manufacturing and quality control of interconnecting wire harnesses, Volume 4

    NASA Technical Reports Server (NTRS)

    1972-01-01

    The document covers interconnecting wire harnesses defined in the design standard, including type 8, flat conductor cable. Volume breadth covers installations of groups of harnesses in a major assembly and the associated post installation inspections and electrical tests. Knowledge gained through experience on the Saturn 5 program coupled with recent advances in techniques, materials, and processes was incorporated into this document.

  3. Estimation of changes in nickel and chromium content in nickel-titanium and stainless steel orthodontic wires used during orthodontic treatment: An analytical and scanning electron microscopic study

    PubMed Central

    Kararia, Vandana; Jain, Pradeep; Chaudhary, Seema; Kararia, Nitin

    2015-01-01

    Introduction: The biocompatibility of orthodontic dental alloys has been investigated over the past 20 years, but the results have been inconclusive. The study compares standard 3 M Unitek nickel-titanium (NiTi) and stainless steel archwires with locally available JJ orthodontics wires. Scanning electron microscope (SEM) study of surface changes and complexometric titration to study compositional change was performed. Materials and Methods: Ten archwires each of group 1–3 M 0.016” NiTi, group 2-JJ 0.016” NiTi, group 3–3 M 0.019” *0.025” SS and group 4-JJ SS contributed a 10 mm piece of wire for analysis prior to insertion in the patient and 6 weeks post insertion. SEM images were recorded at ×2000, ×4000 and ×6000 magnification. The same samples were subjected to complexiometric titration using ethylenediaminetetraacetic acid to gauge the actual change in the composition. Observations and Results: The SEM images of all the archwires showed marked changes with deep scratches and grooves and dark pitting corrosion areas post intraoral use. 3M wires showed an uniform criss-cross pattern in as received wires indicating a coating which was absent after intraoral use. There was a significant release of Nickel and Chromium from both group 3 and 4. Group 2 wires released ions significantly more than group 1 (P = 0.0). Conclusion: Extensive and stringent trials are required before certifying any product to be used in Orthodontics. PMID:25684911

  4. Scalp Wound Closure with K wires: An alternative easier method to scalp wound closure.

    PubMed

    Ramesh, S; Ajik, S

    2012-12-01

    Scalp defects and lacerations present a reconstructive challenge to plastic surgeons. Many methods have been described from the use of skin grafting to rotation flaps. Here we present a method of closure of a contaminated scalp wound with the use of Kirschner wires. In our case, closure of scalp laceration was made possible with the use of 1.4 Kirschner wires and cable tie/ zip tie fasteners. The duration to closure of wound was 10 days. In reconstructing the scalp defect, this method was found to adhere to principles of scalp reconstruction. There were no post operative complications found from the procedure. On initial application on the edge of the wound, tension applied caused the K wires to cut through the wound edge. On replacement of K wires 1cm away from wound edge the procedure was not plagued by any further complication. In conclusion we find scalp closure with Kirschner wires are a simple and effective method for scalp wound closure.

  5. Radiological Source Localisation

    DTIC Science & Technology

    2007-07-01

    activity. This algorithm was able to provide reasonable source estimates based on real data collected using the Low Cost Advanced Airborne...courses in Australia, Europe and the US. He is lecturing a post-graduate subject at Adelaide University (subject ”Multi-Sensor Data Fusion ”). He served on...technical committees of several international conferences, and is the Chair of the Fourth Australian Data Fusion Sym- posium (IDC-07). Dr Ristic won

  6. Wire Detection Algorithms for Navigation

    NASA Technical Reports Server (NTRS)

    Kasturi, Rangachar; Camps, Octavia I.

    2002-01-01

    In this research we addressed the problem of obstacle detection for low altitude rotorcraft flight. In particular, the problem of detecting thin wires in the presence of image clutter and noise was studied. Wires present a serious hazard to rotorcrafts. Since they are very thin, their detection early enough so that the pilot has enough time to take evasive action is difficult, as their images can be less than one or two pixels wide. Two approaches were explored for this purpose. The first approach involved a technique for sub-pixel edge detection and subsequent post processing, in order to reduce the false alarms. After reviewing the line detection literature, an algorithm for sub-pixel edge detection proposed by Steger was identified as having good potential to solve the considered task. The algorithm was tested using a set of images synthetically generated by combining real outdoor images with computer generated wire images. The performance of the algorithm was evaluated both, at the pixel and the wire levels. It was observed that the algorithm performs well, provided that the wires are not too thin (or distant) and that some post processing is performed to remove false alarms due to clutter. The second approach involved the use of an example-based learning scheme namely, Support Vector Machines. The purpose of this approach was to explore the feasibility of an example-based learning based approach for the task of detecting wires from their images. Support Vector Machines (SVMs) have emerged as a promising pattern classification tool and have been used in various applications. It was found that this approach is not suitable for very thin wires and of course, not suitable at all for sub-pixel thick wires. High dimensionality of the data as such does not present a major problem for SVMs. However it is desirable to have a large number of training examples especially for high dimensional data. The main difficulty in using SVMs (or any other example-based learning method) is the need for a very good set of positive and negative examples since the performance depends on the quality of the training set.

  7. Space Shuttle Columbia Aging Wiring Failure Analysis

    NASA Technical Reports Server (NTRS)

    McDaniels, Steven J.

    2005-01-01

    A Space Shuttle Columbia main engine controller 14 AWG wire short circuited during the launch of STS-93. Post-flight examination divulged that the wire had electrically arced against the head of a nearby bolt. More extensive inspection revealed additional damage to the subject wire, and to other wires as well from the mid-body of Columbia. The shorted wire was to have been constructed from nickel-plated copper conductors surrounded by the polyimide insulation Kapton, top-coated with an aromatic polyimide resin. The wires were analyzed via scanning electron microscope (SEM), energy dispersive X-Ray spectroscopy (EDX), and electron spectroscopy for chemical analysis (ESCA); differential scanning calorimetry (DSC) and thermal gravimetric analysis (TGA) were performed on the polyimide. Exemplar testing under laboratory conditions was performed to replicate the mechanical damage characteristics evident on the failed wires. The exemplar testing included a step test, where, as the name implies, a person stepped on a simulated wire bundle that rested upon a bolt head. Likewise, a shear test that forced a bolt head and a torque tip against a wire was performed to attempt to damage the insulation and conductor. Additionally, a vibration test was performed to determine if a wire bundle would abrade when vibrated against the head of a bolt. Also, an abrasion test was undertaken to determine if the polyimide of the wire could be damaged by rubbing against convolex helical tubing. Finally, an impact test was performed to ascertain if the use of the tubing would protect the wire from the strike of a foreign object.

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sun Zhonghua, E-mail: z.sun@curtin.edu.a; Chaichana, Thanapong

    The purpose of the study was to investigate the hemodynamic effect of stent struts (wires) on renal arteries in patients with abdominal aortic aneurysms (AAAs) treated with suprarenal stent-grafts. Two sample patients with AAA undergoing multislice CT angiography pre- and postsuprarenal fixation of stent-grafts were selected for inclusion in the study. Eight juxtarenal models focusing on the renal arteries were generated from the multislice CT datasets. Four types of configurations of stent wires crossing the renal artery ostium were simulated in the segmented aorta models: a single wire crossing centrally, a single wire crossing peripherally, a V-shaped wire crossing centrally,more » and multiple wires crossing peripherally. The blood flow pattern, flow velocity, wall pressure, and wall shear stress at the renal arteries pre- and post-stent-grafting were analyzed and compared using a two-way fluid structure interaction analysis. The stent wire thickness was simulated with a diameter of 0.4, 1.0, and 2.0 mm, and hemodynamic analysis was performed at different cardiac cycles. The interference of stent wires with renal blood flow was mainly determined by the thickness of stent wires and the type of configuration of stent wires crossing the renal ostium. The flow velocity was reduced by 20-30% in most of the situations when the stent wire thickness increased to 1.0 and 2.0 mm. Of the four types of configuration, the single wire crossing centrally resulted in the highest reduction of flow velocity, ranging from 21% to 28.9% among three different wire thicknesses. Wall shear stress was also dependent on the wire thickness, which decreased significantly when the wire thickness reached 1.0 and 2.0 mm. In conclusion, our preliminary study showed that the hemodynamic effect of suprarenal stent wires in patients with AAA treated with suprarenal stent-grafts was determined by the thickness of suprarenal stent wires. Research findings in our study are useful for follow-up of patients treated with suprarenal stent-grafts to ensure long-term safety of the suprarenal fixation.« less

  9. Ultrasound cavitation versus cryolipolysis for non-invasive body contouring.

    PubMed

    Mahmoud ELdesoky, Mohamed Taher; Mohamed Abutaleb, Enas ELsayed; Mohamed Mousa, Gihan Samir

    2015-08-24

    The demand for non-surgical and non-invasive devices is continuous and increasing. Such devices have gradually gained ground in the reduction of localised fat and the improvement of body contouring. The study aimed to compare the effects of ultrasound cavitation and cryolipolysis on localised abdominal fat. In total, 60 participants with a body mass index (BMI) over 30 kg/m 2 , whose age ranged between 25 and 45 years, were included. The participants were randomly assigned to three groups of 20 each, using ultrasound cavitation and diet, cryolipolysis and diet, and diet only (the control group), respectively. Measures were bodyweight, BMI, waist circumference and suprailiac skinfold were measured at the beginning of the study and 2 months later. The three groups showed significant improvements in all measured variables after 2 months. There was no statistically significant difference in bodyweight or in BMI among the groups after treatment. However, the groups using ultrasound cavitation and cryolipolysis showed better post-treatment improvement than the diet-only group in waist circumference and suprailiac skinfold. There was no statistically significant difference post-treatment between the cavitation and cryolipolysis groups in waist circumference or suprailiac skinfold. Both ultrasound cavitation and cryolipolysis are safe and effective for the reduction of abdominal fat thickness and for abdominal contouring. © 2015 The Australasian College of Dermatologists.

  10. Placental expression of EG-VEGF and its receptors PKR1 (prokineticin receptor-1) and PKR2 throughout mouse gestation.

    PubMed

    Hoffmann, P; Feige, J-J; Alfaidy, N

    2007-10-01

    Compelling evidence indicates that vascular endothelial growth factor (VEGF) is an important mediator of placental angiogenesis and appears to be disregulated in pre-eclampsia (PE). Recently, we characterised the expression of EG-VEGF (endocrine gland-derived vascular endothelial growth factor), also known as prokineticin 1 (PK1) in human placenta during the first trimester of pregnancy and showed that this factor is likely to play an important role in human placentation. However, because it is impossible to prospectively study placentation in humans, it has been impossible to further characterise EG-VEGF expression throughout complete gestation and especially at critical gestational ages for PE development. In the present study, we used mouse placenta to further characterise EG-VEGF expression throughout gestation. We investigated the pattern of expression of EG-VEGF and its receptors, PKR1 and PKR2 at the mRNA and protein levels. Our results show that EG-VEGF and VEGF exhibit different patterns of expression and different localisations in the mouse placenta. EG-VEGF was mainly localised in the labyrinth whereas VEGF was mainly present in glycogen and giant cells. EG-VEGF mRNA and protein levels were highest before 10.5days post coitus (dpc) whereas those of VEGF showed stable expression throughout gestation. PKR1 protein was localised to the labyrinth layer and showed the same pattern of expression as EG-VEGF whereas PKR2 expression was maintained over 10.5dpc with both trophoblastic and endothelial cell localisations. Altogether these findings suggest that EG-VEGF may have a direct effect on both endothelial and trophoblastic cells and is likely to play an important role in mouse placentation.

  11. Co-localisation of advanced glycation end products and D-β-aspartic acid-containing proteins in gelatinous drop-like corneal dystrophy.

    PubMed

    Kaji, Yuichi; Oshika, Tetsuro; Takazawa, Yutaka; Fukayama, Masashi; Fujii, Noriko

    2012-08-01

    Gelatinous drop-like corneal dystrophy (GDLD), also known as familial subepithelial corneal amyloidosis, is an autosomal recessive disorder that causes progressive corneal opacity due to accumulation of amyloid fibrils in the corneal stroma. Genetic analyses have revealed that a mutation in membrane component chromosome 1 surface marker 1 gene is responsible for GDLD. However, the mechanism of amyloid formation in the corneal stroma remains unclear. The present study attempted to reveal the role of advanced glycation end products (AGE) and d-amino acids in amyloid formation in GDLD. Informed consent was obtained from five patients with GDLD, three patients with bullous keratopathy and three patients with interstitial keratitis and all the specimens were analysed. Localisation of amyloid fibrils was analysed using Congo-red and thioflavin T staining. In addition, the localisation of AGE (N(ε)-carboxy(methyl)-L-lysine, pyrraline and pentosidine) and D-β-aspartic acid-containing proteins, a major form of d-amino acid-containing proteins, was analysed immunohistochemically. In all GDLD specimens, strong immunoreactivity to AGE and D-β-aspartic acid-containing proteins was detected in the subepithelial amyloid-rich region. In contrast, amyloid fibrils, AGE, or D-amino acid-containing proteins were slightly detected in the corneal stroma of patients with bullous keratopathy and interstitial keratitis. Abnormally accumulated proteins rich in AGE and D-β-aspartic acid co-localise in the amyloid lesions in GDLD. These results indicate that non-enzymatic post-translational modifications of proteins, including AGE formation and isomerisation of aspartyl residues, will be the cause as well as the result of amyloid fibril formations in GDLD.

  12. Co-localisation of advanced glycation end products and d-β-aspartic acid-containing proteins in gelatinous drop-like corneal dystrophy

    PubMed Central

    Oshika, Tetsuro; Takazawa, Yutaka; Fukayama, Masashi; Fujii, Noriko

    2012-01-01

    Purpose Gelatinous drop-like corneal dystrophy (GDLD), also known as familial subepithelial corneal amyloidosis, is an autosomal recessive disorder that causes progressive corneal opacity due to accumulation of amyloid fibrils in the corneal stroma. Genetic analyses have revealed that a mutation in membrane component chromosome 1 surface marker 1 gene is responsible for GDLD. However, the mechanism of amyloid formation in the corneal stroma remains unclear. The present study attempted to reveal the role of advanced glycation end products (AGE) and d-amino acids in amyloid formation in GDLD. Methods Informed consent was obtained from five patients with GDLD, three patients with bullous keratopathy and three patients with interstitial keratitis and all the specimens were analysed. Localisation of amyloid fibrils was analysed using Congo-red and thioflavin T staining. In addition, the localisation of AGE (Nɛ-carboxy(methyl)-l-lysine, pyrraline and pentosidine) and d-β-aspartic acid-containing proteins, a major form of d-amino acid-containing proteins, was analysed immunohistochemically. Results In all GDLD specimens, strong immunoreactivity to AGE and d-β-aspartic acid-containing proteins was detected in the subepithelial amyloid-rich region. In contrast, amyloid fibrils, AGE, or d-amino acid-containing proteins were slightly detected in the corneal stroma of patients with bullous keratopathy and interstitial keratitis. Conclusions Abnormally accumulated proteins rich in AGE and d-β-aspartic acid co-localise in the amyloid lesions in GDLD. These results indicate that non-enzymatic post-translational modifications of proteins, including AGE formation and isomerisation of aspartyl residues, will be the cause as well as the result of amyloid fibril formations in GDLD. PMID:22694960

  13. Mechanically adaptive intracortical implants improve the proximity of neuronal cell bodies

    PubMed Central

    Harris, J P; Capadona, J R; Miller, R H; Healy, B C; Shanmuganathan, K; Rowan, S J; Weder, C; Tyler, D J

    2012-01-01

    The hypothesis is that mechanical mismatch between brain tissue and microelectrodes influences the inflammatory response. Our unique, mechanically-adaptive polymer nanocomposite enabled this study within the cerebral cortex of rats. The initial tensile storage modulus of 5 GPa decreases to 12 MPa within 15 minutes under physiological conditions. The response to the nanocomposite was compared to surface-matched, stiffer implants of traditional wires (411 GPa) coated with the identical polymer substrate and implanted on the contralateral side. Both implants were tethered. Fluorescent immunohistochemistry labeling examined neurons, intermediate filaments, macrophages, microglia, and proteoglycans. We demonstrate, for the first time, a system that decouples the mechanical and surface chemistry components of the neural response. The neuronal nuclei density within 100 μm of the device at four weeks post implantation was greater for the compliant nanocomposite compared to the stiff wire. At eight weeks post implantation, the neuronal nuclei density around the nanocomposite was maintained, but the density around the wire recovered to match the nanocomposite. The glial scar response to the compliant nanocomposite was less vigorous than to the stiffer wire. The results suggest that mechanically associated factors such as proteoglycans and intermediate filaments are important modulators of the response of the compliant nanocomposite. PMID:22049097

  14. Effect of fluoride prophylactic agents on the mechanical properties of nickel-titanium-based orthodontic wires.

    PubMed

    Walker, Mary P; White, Richard J; Kula, Katherine S

    2005-06-01

    Titanium-based alloys have high corrosion resistance because they form a thin, stable oxide layer. Nevertheless, fluoride prophylactic agents can cause corrosion and associated discoloration of titanium-based orthodontic wires. The purpose of this investigation was to study the effects of fluoride prophylactic agents on the mechanical properties of nickel-titanium (Ni-Ti) and copper-nickel-titanium (Cu-Ni-Ti) orthodontic archwires. Preformed rectangular Ni-Ti and Cu-Ni-Ti wires were immersed in either an acidulated fluoride agent, a neutral fluoride agent, or distilled water (control) for 1.5 hours at 37 degrees C. After immersion, the loading and unloading elastic modulus and yield strength of the wires were measured with a 3-point bend test in a water bath at 37 degrees C, in accordance with the criteria in the current American National Standard/American Dental Association Specification No. 32 for Orthodontic Wires (2000). Scanning electron microscopy was also used to characterize the effects of the fluoride treatment on the wire topography. Unloading mechanical properties of Ni-Ti orthodontic wires were significantly decreased after exposure to both fluoride agents (1-way analysis of variance [ANOVA] and Dunnett's post hoc, alpha =.05); however, Cu-Ni-Ti wire mechanical properties were not significantly affected by either fluoride agent (1-way ANOVA, alpha =.05). Corrosive changes in surface topography were observed for both wires, with Cu-Ni-Ti appearing to be more severely affected. The results suggest that using topical fluoride agents with Ni-Ti wire could decrease the functional unloading mechanical properties of the wire and contribute to prolonged orthodontic treatment.

  15. Land-Based Dlischarge Environmental Assessment at Beale Air Force Base, California

    DTIC Science & Technology

    2009-09-01

    Attainment Designations ................. 3-3 3-3 Federally Listed Species Evaluated...drain pit includes special design features to ensure that drained effluent does not enter Hutchinson Creek. The drain pit would consist of a pipe with...The cattle fence would consist of metal T- posts , five-strand cattle wire, and a standard cattle gate with wooden posts . The wooden posts would be

  16. Obstacle Detection Algorithms for Rotorcraft Navigation

    NASA Technical Reports Server (NTRS)

    Kasturi, Rangachar; Camps, Octavia I.; Huang, Ying; Narasimhamurthy, Anand; Pande, Nitin; Ahumada, Albert (Technical Monitor)

    2001-01-01

    In this research we addressed the problem of obstacle detection for low altitude rotorcraft flight. In particular, the problem of detecting thin wires in the presence of image clutter and noise was studied. Wires present a serious hazard to rotorcrafts. Since they are very thin, their detection early enough so that the pilot has enough time to take evasive action is difficult, as their images can be less than one or two pixels wide. After reviewing the line detection literature, an algorithm for sub-pixel edge detection proposed by Steger was identified as having good potential to solve the considered task. The algorithm was tested using a set of images synthetically generated by combining real outdoor images with computer generated wire images. The performance of the algorithm was evaluated both, at the pixel and the wire levels. It was observed that the algorithm performs well, provided that the wires are not too thin (or distant) and that some post processing is performed to remove false alarms due to clutter.

  17. Retrograde intubation: an alternative way for the management of difficult airway.

    PubMed

    Lama, P; Shrestha, B R

    2008-01-01

    Inserting a retrograde wire into the pharynx through a cricothyroid puncture can facilitate tracheal intubation in difficult situations where either a flexible fiber-optic bronchoscope or an expert user of such a device is not available. Even in cases when fibropric can not be negotiated for the purpose, this method has been claimed to be useful to manage the airway. Some mouth opening is essential for the oral or nasal retrieval of the wire from the pharynx. Here, a case of post mandibular reconstructed wound infection required surgical debridement and plate removal from reconstructed lower mandible under general anesthesia. We retrieved the guide wire passed through a cricothyroid puncture and subsequently accomplished wire-guided oro-tracheal intubation. In the absence of a flexible fiber-optic bronchoscope, this technique is a very useful aid to intubate patients with limited mouth opening.

  18. Radioguided localisation of non-palpable lesions of the breast in Costa Rica: review of results of our first 800 patients in private practice.

    PubMed

    Aguilar, Marisel; Alfaro, Sabrina; Aguilar, Ricardo

    2017-01-01

    Surgical treatment of non-palpable breast lesions is controversial. At the European Institute of Oncology in Milan, Italy, Prof Umberto Veronesi introduced a new technique called the radioguided occult lesion localisation (ROLL) in 1996 to replace conventional methods and their disadvantages (Zurrida S, Galimberti V, and Monti S et al (1998) Radioguided localization of occult breast lesions Breast 7 11-13 https://doi.org/10.1016/S0960-9776(98)90044-3). Given the success experienced in that institution, the method became the technique of choice for the early diagnosis of breast cancer. In this paper, we will examine the technical aspects of ROLL and the results from a large series of patients treated in our private practice in Costa Rica. We analysed the first 816 patients with different non-palpable breast lesions detected by ultrasound or mammography within our private practice in Costa Rica. In 774 patients, technetium 99m labelled with human serum albumin (7-10 MBq) in 0.2 ml of saline solution was injected into the lesion under mammographic or ultrasound guidance. The excisional biopsy was done by means of a gamma-probe and complete excision of the lesion was verified by X-ray on the specimen in lesions that were visible by mammography and ultrasound 4 months after surgery. In the remaining 42 patients, the localisation of the lesion was carried out by wire. The tracer was correctly positioned in the first attempt in 772/816 (94.6%) of cases and in the second attempt in two other cases. In 42/816 (5.1%) cases, the localisation of the lesion had to be performed with the traditional method. X-rays showed that the lesion was entirely removed in 770/772 (99.74%) of cases. The ROLL is a simple and excellent option for the removal of hidden breast lesions in clinical practice. It offers the advantage of making resections safer and with tumour-free margins, in addition to reducing the number of reinterventions. Since it makes it possible to specify to the pathologist the exact site where the lesion is located, we can guarantee a better diagnosis. The rate of success with the use of this technique corresponds to the available scientific data, so we conclude that it is a procedure that we can routinely perform in private practice in Costa Rica.

  19. The Effect of Material Removal on the Corrosion Resistance and Biocompatibility of Nitinol Laser-Cut and Wire-Form Products

    NASA Astrophysics Data System (ADS)

    Decker, Jennifer Fino; Trépanier, Christine; Vien, Lot; Pelton, Alan R.

    2011-07-01

    Laser cutting and wire forming are two of the most commonly used processes in the manufacture of Nitinol medical devices. This study explores how varying the amount of material removed during the final surface treatment steps affects the corrosion resistance of Z-type stents that have either been laser-cut from tube or shape set from wire. All parts were subjected to a typical heat treatment process necessary to achieve an Austenite finish (Af) temperature of 25 ± 5 °C, and were subsequently post-processed with an electrochemical passivation process. The total weight loss during post-processing was recorded and the process adjusted to create groups with less than 5%, less than 10%, and less than 25% amounts of weight loss. The parts were then crimped to 6 mm and allowed to expand back to their original diameter. The corrosion test results showed that on average both groups of Z-stents experienced an increase in the corrosion breakdown potential and a decrease in the standard deviation with increasing amounts of material removal. In addition, less material removal is required from the wire-form Z-stents as compared to the laser-cut Z-stents to achieve high corrosion resistance. Finally, 7 day nickel ion release tests performed on the wire-formed Z-stents showed a dramatic decrease from 0.0132 mg of nickel leached per day for the low weight loss group to approximately 0.001 mg/day for the medium and high weight loss groups.

  20. Immunolocalisation of oestrogen receptors alpha (ERalpha) and beta (ERbeta) in porcine embryos and fetuses at different stages of gestation.

    PubMed

    Knapczyk, Katarzyna; Duda, Malgorzata; Szafranska, Bozena; Wolsza, Katarzyna; Panasiewicz, Grzegorz; Koziorowski, Marek; Slomczynska, Maria

    2008-06-01

    The sites of oestrogen action can be shown by the localisation of their receptors in the target tissues. The aim of the present study was to show the localisation of oestrogen receptors in porcine embryos and fetuses obtained on days 18, 22, 32, 40, 50, 60, 71 and 90 post coitum (p.c.). The visualisation of proteins was conducted in embryos and various fetal organs such as gonads, uterus, lung, kidney, intestine and adrenal gland. Both ERs were observed in the blastocysts on day 18 p.c. In the male, ERbeta was detected in the testis and epididymis, whereas ERalpha was present in the efferent ductules. In the female, ERbeta was detected in the ovarian stromal cells investing the oocyte nests, while ERalpha protein was detected in the surface epithelium. In the uterus, ERs were present in the stromal cells, while ERbeta was present in the luminal epithelium. In the non-reproductive fetal porcine tissues ERbeta was localised in the lungs, kidneys, adrenal glands and in the umbilical cords. Both ERs were observed in the intestine. It is possible that ERbeta may play important roles in the development of the adrenal gland, testis, kidney and lungs, while both ERs are involved in the development of the ovary, uterus, epididymis and intestine of the porcine fetus.

  1. Electrolytic ablation of the rat pancreas: a feasibility trial

    PubMed Central

    Fosh, Beverley G; Finch, Jonathon Guy; Anthony, Adrian A; Texler, Michael; Maddern, Guy J

    2001-01-01

    Background Pancreatic cancer is a biologically aggressive disease with less than 20% of patients suitable for a "curative" surgical resection. This, combined with the poor 5-year survival indicates that effective palliative methods for symptom relief are required. Currently there are no ablative techniques to treat pancreatic cancer in clinical use. Tissue electrolysis is the delivery of a direct current between an anode and cathode to induce localised necrosis. Electrolysis has been shown to be safe and reliable in producing hepatic tissue and tumour ablation in animal models and in a limited number of patients. This study investigates the feasibility of using electrolysis to produce localised pancreatic necrosis in a healthy rat model. Method Ten rats were studied in total. Eight rats were treated with variable "doses" of coulombs, and the systemic and local effects were assessed; 2 rats were used as controls. Results Seven rats tolerated the procedure well without morbidity or mortality, and one died immediately post procedure. One control rat died on induction of anaesthesia. Serum amylase and glucose were not significantly affected. Conclusion Electrolysis in the rat pancreas produced localised necrosis and appears both safe, and reproducible. This novel technique could offer significant advantages for patients with unresectable pancreatic tumours. The next stage of the study is to assess pancreatic electrolysis in a pig model, prior to human pilot studies. PMID:11570977

  2. Fabricating Superior NiAl Bronze Components through Wire Arc Additive Manufacturing.

    PubMed

    Ding, Donghong; Pan, Zengxi; van Duin, Stephen; Li, Huijun; Shen, Chen

    2016-08-03

    Cast nickel aluminum bronze (NAB) alloy is widely used for large engineering components in marine applications due to its excellent mechanical properties and corrosion resistance. Casting porosity, as well as coarse microstructure, however, are accompanied by a decrease in mechanical properties of cast NAB components. Although heat treatment, friction stir processing, and fusion welding were implemented to eliminate porosity, improve mechanical properties, and refine the microstructure of as-cast metal, their applications are limited to either surface modification or component repair. Instead of traditional casting techniques, this study focuses on developing NAB components using recently expanded wire arc additive manufacturing (WAAM). Consumable welding wire is melted and deposited layer-by-layer on substrates producing near-net shaped NAB components. Additively-manufactured NAB components without post-processing are fully dense, and exhibit fine microstructure, as well as comparable mechanical properties, to as-cast NAB alloy. The effects of heat input from the welding process and post-weld-heat-treatment (PWHT) are shown to give uniform NAB alloys with superior mechanical properties revealing potential marine applications of the WAAM technique in NAB production.

  3. Fabricating Superior NiAl Bronze Components through Wire Arc Additive Manufacturing

    PubMed Central

    Ding, Donghong; Pan, Zengxi; van Duin, Stephen; Li, Huijun; Shen, Chen

    2016-01-01

    Cast nickel aluminum bronze (NAB) alloy is widely used for large engineering components in marine applications due to its excellent mechanical properties and corrosion resistance. Casting porosity, as well as coarse microstructure, however, are accompanied by a decrease in mechanical properties of cast NAB components. Although heat treatment, friction stir processing, and fusion welding were implemented to eliminate porosity, improve mechanical properties, and refine the microstructure of as-cast metal, their applications are limited to either surface modification or component repair. Instead of traditional casting techniques, this study focuses on developing NAB components using recently expanded wire arc additive manufacturing (WAAM). Consumable welding wire is melted and deposited layer-by-layer on substrates producing near-net shaped NAB components. Additively-manufactured NAB components without post-processing are fully dense, and exhibit fine microstructure, as well as comparable mechanical properties, to as-cast NAB alloy. The effects of heat input from the welding process and post-weld-heat-treatment (PWHT) are shown to give uniform NAB alloys with superior mechanical properties revealing potential marine applications of the WAAM technique in NAB production. PMID:28773774

  4. Librarian Recruitment Process at Home in the Wired Nation.

    ERIC Educational Resources Information Center

    Nesbeitt, Sarah

    2003-01-01

    Discusses the trend toward online recruitment for librarians and describes a survey of library employees who had posted jobs online. Topics include reasons for online job postings; where positions were advertised, including types of Web sites and print media; electronic communication and emailed resumes; and the future of online recruitment. (LRW)

  5. Biomechanical comparison of fixation methods in transverse patella fractures.

    PubMed

    Scilaris, T A; Grantham, J L; Prayson, M J; Marshall, M P; Hamilton, J J; Williams, J L

    1998-01-01

    To compare monofilament wire versus braided cable for stabilizing transverse patella fractures using the modified AO tension band technique. A randomized blocked (paired) study comparing two fixation methods. Statistical analysis was performed using a nested repeated measures analysis, followed by Bonferroni post hoc testing. Seven paired embalmed knees (mean age 71.8 years, SD 14.6 years) were dissected, and transverse fractures were simulated. The knees were reduced and randomly fixed by either two parallel 0.062-inch Kirschner wires with a 1.0-millimeter-diameter 316L stainless steel monofilament wire tension loop or two Kirschner wires with a 1.0-millimeter-diameter 316L stainless steel braided cable tension loop. Knees were tested by applying a cyclic load through the suprapatellar tendon between twenty and 300 newtons for thirty cycles. The maximum fracture displacement increased with each cycle of loading for both the braided cable and monofilament wire tension loop configurations (p = 0.0001). The average peak displacement at the thirtieth cycle was 2.25 millimeters for monofilament wire and 0.73 millimeters for the cable. When comparing both methods for all cycles, the braided cable allowed less fracture displacement than did the monofilament wire (p = 0.002), and the rate of increase per cycle of maximum fracture displacement was less for the cable than for the wire (p = 0.0001). In transverse, noncomminuted patella fractures, fixation with two Kirschner wires and a 1.0-millimeter braided cable tension loop was superior to the monofilament wire tension loop. Most importantly, the braided cable afforded more predictable results during cyclic loading.

  6. Wire Chambers and Cherenkov Detectors at Fermilab Test Beam Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tame Narvaez, Karla

    2017-01-01

    Fermilab Test Beam Facility (FTBF) is dedicated to helping scientists test their prototypes. For this, FTBF has instrumentation that is very useful for the users. However, before a user can test a detector, it is necessary to ensure the facility has the characteristics they need. During this summer, we studied beam properties by collecting Cherenkov and wire chamber data. Analyzed data will be used for updating the general information that FTBF posts on a web page.

  7. Shaping ability of two M-wire and two traditional nickel-titanium instrumentation systems in S-shaped resin canals.

    PubMed

    Ceyhanli, K T; Kamaci, A; Taner, M; Erdilek, N; Celik, D

    2015-01-01

    The aim of this study was to evaluate the shaping effects of two M-wire and two traditional nickel-titanium (NiTi) rotary systems in simulated S-shaped resin canals. Forty simulated S-shaped canals in resin blocks were instrumented with two traditional (ProTaper, Sendoline S5) and two M-wire (WaveOne, GT series X) NiTi systems according to the manufacturers' instructions. Ten resin blocks were used for each system. Pre- and post-instrumentation images were captured using a stereomicroscope and superimposed with an image program. Canal transportation, material removal, and aberrations were evaluated and recorded as numeric parameters. Data were analyzed using one-way ANOVA and post-hoc Tukey tests with a 95% confidence interval. There were significant differences between systems in terms of transportation and material removal (P<0.05). Coronal danger zone was the most common aberration. Within the limits of this ex vivo study, it was found that the manufacturing methods (M-wire or traditional NiTi) and kinematics (rotary or reciprocating motion) did not affect the shaping abilities of the systems. The extended file designs of highly tapered NiTi systems (ProTaper, WaveOne) resulted in greater deviations from the original root canal trace and more material removal when compared to less tapered systems (Sendoline S5, GT series X).

  8. Corrosion of post-tensioning strands in ungrouted ducts - unstressed condition

    NASA Astrophysics Data System (ADS)

    Hutchison, Michael

    Recent failures and severe corrosion distress of post-tensioned (PT) bridges in Florida have revealed corrosion of the 7-wire strands in tendons. Post-tensioned duct assemblies are fitted with multiple 7-wire steel strands and ducts are subsequently filled with grout. During construction, the length of time from the moment in which the strands have been inserted into the ducts, until the ducts are grouted, is referred to as the `ungrouted' period. During this phase, the steel strands are vulnerable to corrosion and consequently the length of this period is restricted (typically to 7 days) by construction guidelines. This investigation focuses on determining the extent of corrosion that may take place during that period, but limited to strands that were in the unstressed condition. Visual inspections and tensile testing were used to identify trends in corrosion development. Corrosion induced cracking mechanisms were also investigated via wire bending and metallographic cross section evaluation. Corrosion damage on unstressed strands during ungrouted periods of durations in the order of those otherwise currently prescribed did not appear to seriously degrade mechanical performance as measured by standardized tests. However the presence of stress in the ungrouted period, as is normally the case, may activate other mechanisms (e.g., EAC) that require further investigation. As expected in the unstressed condition, no evidence of transverse cracking was observed.

  9. Quality of Life Outcomes after Primary Treatment for Clinically Localised Prostate Cancer: A Systematic Review.

    PubMed

    Lardas, Michael; Liew, Matthew; van den Bergh, Roderick C; De Santis, Maria; Bellmunt, Joaquim; Van den Broeck, Thomas; Cornford, Philip; Cumberbatch, Marcus G; Fossati, Nicola; Gross, Tobias; Henry, Ann M; Bolla, Michel; Briers, Erik; Joniau, Steven; Lam, Thomas B; Mason, Malcolm D; Mottet, Nicolas; van der Poel, Henk G; Rouvière, Olivier; Schoots, Ivo G; Wiegel, Thomas; Willemse, Peter-Paul M; Yuan, Cathy Yuhong; Bourke, Liam

    2017-12-01

    Current evidence-based management for clinically localised prostate cancer includes active surveillance, surgery, external beam radiotherapy (EBRT) and brachytherapy. The impact of these treatment modalities on quality of life (QoL) is uncertain. To systematically review comparative studies investigating disease-specific QoL outcomes as assessed by validated cancer-specific patient-reported outcome measures with at least 1 yr of follow-up after primary treatment for clinically localised prostate cancer. MEDLINE, EMBASE, AMED, PsycINFO, and Cochrane Library were searched to identify relevant studies. Studies were critically appraised for the risk of bias. A narrative synthesis was undertaken. Of 11486 articles identified, 18 studies were eligible for inclusion, including three randomised controlled trials (RCTs; follow-up range: 60-72 mo) and 15 nonrandomised comparative studies (follow-up range: 12-180 mo) recruiting a total of 13604 patients. Two RCTs recruited small cohorts and only one was judged to have a low risk of bias. The quality of evidence from observational studies was low to moderate. For a follow-up of up to 6 yr, active surveillance was found to have the lowest impact on cancer-specific QoL, surgery had a negative impact on urinary and sexual function when compared with active surveillance and EBRT, and EBRT had a negative impact on bowel function when compared with active surveillance and surgery. Data from one small RCT reported that brachytherapy has a negative impact on urinary function 1 yr post-treatment, but no significant urinary toxicity was reported at 5 yr. This is the first systematic review comparing the impact of different primary treatments on cancer-specific QoL for men with clinically localised prostate cancer, using validated cancer-specific patient-reported outcome measures only. There is robust evidence that choice of primary treatment for localised prostate cancer has distinct impacts on patients' QoL. This should be discussed in detail with patients during pretreatment counselling. Our review of the current evidence suggests that for a period of up to 6 yr after treatment, men with localised prostate cancer who were managed with active surveillance reported high levels of quality of life (QoL). Men treated with surgery reported mainly urinary and sexual problems, while those treated with external beam radiotherapy reported mainly bowel problems. Men eligible for brachytherapy reported urinary problems up to a year after therapy, but then their QoL returned gradually to as it was before treatment. Copyright © 2017 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  10. Toxic shock syndrome post open reduction and Kirschner wire fixation of a humeral lateral condyle fracture

    PubMed Central

    Chan, Yuen; Selvaratnam, Veenesh; Garg, Neeraj

    2015-01-01

    Use of Kirschner wires (K-wires) is the most common method of fracture stabilisation in lateral condyle fracture fixation in children. We report a case of toxic shock syndrome (TSS) following an open reduction and internal fixation using K-wires for a humeral lateral condyle fracture in a 5-year-old girl. TSS is a toxin-mediated multisystem illness. It typically presents with shock and it is most often attributed to toxin-producing strains of Staphylococcus aureus and Streptococcus pyogenes. It can lead to multiorgan failure and, ultimately, death. It is important to be aware of TSS, as it can present within any setting. Patients often have non-specific symptoms and their condition can worsen rapidly. TSS postorthopaedic surgery is rare; however, due to the serious nature of this disease, it is important to promptly recognise and diagnose TSS, and to ensure appropriate treatment is started without delay. PMID:26264942

  11. Production of Oxidation-Resistant Cu-Based Nanoparticles by Wire Explosion

    PubMed Central

    Kawamura, Go; Alvarez, Samuel; Stewart, Ian E.; Catenacci, Matthew; Chen, Zuofeng; Ha, Yoon-Cheol

    2015-01-01

    The low performance or high cost of commercially available conductive inks limits the advancement of printed electronics. This article studies the explosion of metal wires in aqueous solutions as a simple, low-cost, and environmentally friendly method to prepare metallic nanoparticles consisting of Cu and Cu alloys for use in affordable, highly conductive inks. Addition of 0.2 M ascorbic acid to an aqueous explosion medium prevented the formation of Cu2O shells around Cu nanoparticles, and allowed for the printing of conductive lines directly from these nanoparticles with no post-treatment. Cu alloy nanoparticles were generated from metal wires that were alloyed as purchased, or from two wires of different metals that were twisted together. Cu nanoparticles alloyed with 1% Sn, 5% Ag, 5% Ni and 30% Ni had electrical conductivities similar to Cu but unlike Cu, remained conductive after 24 hrs at 85 °C and 85% RH. PMID:26669447

  12. Synthesis and Characterization of CuFe 2O 4 Nano/Submicron Wire–Carbon Nanotube Composites as Binder-free Anodes for Li-Ion Batteries

    DOE PAGES

    Wang, Lei; Bock, David C.; Li, Jing; ...

    2018-02-20

    Here, a series of one-dimensional CuFe 2O 4 nano/sub-micron wires possessing different diameters, crystal phases, and crystal sizes have been successfully generated using a facile template-assisted co precipitation reaction at room temperature, followed by a short post-annealing process. The diameter and the crystal structure of the resulting CuFe 2O4 (CFO) wires were judiciously tuned by varying the pore size of the template and the post-annealing temperature, respectively. Carbon nanotubes (CNTs) were incorporated to generate CFO-CNT binder-free anodes, and multiple characterization techniques were employed with the goal of delineating the relationships between electrochemical behavior and the properties of both the CFOmore » wires (crystal phase, wire diameter, crystal size) and the electrode architecture (binder-free vs. conventionally prepared approaches). The study reveals several notable findings. First, the crystal phase (cubic or tetragonal) did not influence the electrochemical behavior in this CFO system. Second, regarding crystallite size and wire diameter, CFO wires with larger crystallite sizes exhibit improved cycling stability, while wires possessing smaller diameters exhibiting higher capacities. Finally, the electrochemical behavior is strongly influenced by the electrode architecture, with CFO-CNT binder-free electrodes demonstrating significantly higher capacities and cycling stability compared to conventionally prepared coatings. The mechanism(s) associated with the high capacities under low current density but limited electrochemical reversibility of CFO electrodes under high current density were probed via x-ray absorption spectroscopy (XAS) mapping with sub-micron spatial resolution for the first time. Results suggest that the capacity of the binder-free electrodes under high rate is limited by the irreversible formation of Cu 0, as well as limited reduction of Fe 3+, to Fe 2+ not Fe 0. The results (1) shed fundamental insight into the reversibility of CuFe 2O 4 materials cycled at high current density and (2) demonstrate that a synergistic effort to control both active material morphology and electrode architecture is an effective strategy for optimizing electrochemical behavior.« less

  13. Synthesis and Characterization of CuFe 2O 4 Nano/Submicron Wire–Carbon Nanotube Composites as Binder-free Anodes for Li-Ion Batteries

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Lei; Bock, David C.; Li, Jing

    Here, a series of one-dimensional CuFe 2O 4 nano/sub-micron wires possessing different diameters, crystal phases, and crystal sizes have been successfully generated using a facile template-assisted co precipitation reaction at room temperature, followed by a short post-annealing process. The diameter and the crystal structure of the resulting CuFe 2O4 (CFO) wires were judiciously tuned by varying the pore size of the template and the post-annealing temperature, respectively. Carbon nanotubes (CNTs) were incorporated to generate CFO-CNT binder-free anodes, and multiple characterization techniques were employed with the goal of delineating the relationships between electrochemical behavior and the properties of both the CFOmore » wires (crystal phase, wire diameter, crystal size) and the electrode architecture (binder-free vs. conventionally prepared approaches). The study reveals several notable findings. First, the crystal phase (cubic or tetragonal) did not influence the electrochemical behavior in this CFO system. Second, regarding crystallite size and wire diameter, CFO wires with larger crystallite sizes exhibit improved cycling stability, while wires possessing smaller diameters exhibiting higher capacities. Finally, the electrochemical behavior is strongly influenced by the electrode architecture, with CFO-CNT binder-free electrodes demonstrating significantly higher capacities and cycling stability compared to conventionally prepared coatings. The mechanism(s) associated with the high capacities under low current density but limited electrochemical reversibility of CFO electrodes under high current density were probed via x-ray absorption spectroscopy (XAS) mapping with sub-micron spatial resolution for the first time. Results suggest that the capacity of the binder-free electrodes under high rate is limited by the irreversible formation of Cu 0, as well as limited reduction of Fe 3+, to Fe 2+ not Fe 0. The results (1) shed fundamental insight into the reversibility of CuFe 2O 4 materials cycled at high current density and (2) demonstrate that a synergistic effort to control both active material morphology and electrode architecture is an effective strategy for optimizing electrochemical behavior.« less

  14. Soviet Naval Special Purpose Forces: Origins and Operations in World War II

    DTIC Science & Technology

    1989-12-01

    amphibious aircraft onto a lake, from which they walked into the area between Nikel and Luostari and back out again. Their journey lasted ten days and...moved up into the snow-covered hills, and after some hours of movement, followed a tele- phone wire to a German guard post. Without carefully observing...telephone wire in rolls. They moved all the captured materiel to shore, and then to their base. The detachment now had enemy guns and ammunition for use

  15. Flightfax - Army Aviation Risk-Management Information. Volume 25, Number 11, August 1997. Snow

    DTIC Science & Technology

    1997-08-01

    but why haven’t Loach that would ensure our surviving a multiple- you been acknowledging the radio calls?" A quick wire strike. check confirmed that...helicopter upright with only the collective and Loach on post with skid shoes, the skid cleats would pedals. have snagged the middle wire and flipped...is more cost effective to overhaul until because masking violated FAA Mr. Ken Muzzo, DSN 490-2257 (314-260- the retirement life is reached. The

  16. A comparative study to check fracture strength of provisional fixed partial dentures made of autopolymerizing polymethylmethacrylate resin reinforced with different materials: An in vitro study.

    PubMed

    Gupt, Parikshit; Nagpal, Archana; Samra, Rupandeep Kaur; Verma, Ramit; Kaur, Jasjeet; Abrol, Surbhi

    2017-01-01

    The purpose of the study was to evaluate the fracture strength of provisional fixed partial dentures made of autopolymerizing polymethylmethacrylate (PMMA) resin using different types of reinforcement materials to determine the best among them. Fifty samples were made (10 samples for each group) with autopolymerizing PMMA resin using reinforcement materials (stainless steel wire: looped and unlooped and glass fiber: loose and unidirectional) as 3-unit posterior bridge. The test specimens were divided into five groups depending on the reinforcing material as Group I, II, III, IV, and V; Group I: PMMA unreinforced (control group), Group II: PMMA reinforced with stainless steel wire (straight ends), Group III: PMMA reinforced with stainless steel wire (looped ends), Group IV: PMMA reinforced with unidirectional glass fibers, and Group V: PMMA reinforced with randomly distributed glass fibers. Universal testing machine was used to evaluate and compare the fracture strength of samples. Comparison of mean ultimate force and ultimate stress was done employing one-way analysis of variance and Tukey's post hoc tests. The highest and lowest mean ultimate force and mean ultimate stress were of Group IV and I, respectively. Tukey's post hoc honestly significant difference multiple comparison for mean ultimate force and stress shows the increase in strength to be statistically significant ( P < 0.05) except for the samples reinforced with randomly distributed glass fibers ( P > 0.05). Unidirectional glass fibers showed the maximum strength, which was comparable to mean values of both stainless steel wire groups. Low cost and easy technique of using stainless steel wire make it the material of choice over the unidirectional glass fiber for reinforcement in nonesthetic areas where high strength is required.

  17. Separate vertical wiring for the fixation of comminuted fractures of the inferior pole of the patella.

    PubMed

    Song, Hyung Keun; Yoo, Je Hyun; Byun, Young Soo; Yang, Kyu Hyun

    2014-05-01

    Among patients over 50 years of age, separate vertical wiring alone may be insufficient for fixation of fractures of the inferior pole of the patella. Therefore, mechanical and clinical studies were performed in patients over the age of 50 to test the strength of augmentation of separate vertical wiring with cerclage wire (i.e., combined technique). Multiple osteotomies were performed to create four-part fractures in the inferior poles of eight pairs of cadaveric patellae. One patella from each pair was fixed with the separate wiring technique, while the other patella was fixed with a combined technique. The ultimate load to failure and stiffness of the fixation were subsequently measured. In a clinical study of 21 patients (average age of 64 years), comminuted fractures of the inferior pole of the patellae were treated using the combined technique. Operative parameters were recorded from which post-operative outcomes were evaluated. For cadaveric patellae, whose mean age was 69 years, the mean ultimate loads to failure for the separate vertical wiring technique and the combined technique were 216.4±72.4 N and 324.9±50.6 N, respectively (p=0.012). The mean stiffness for the separate vertical wiring technique and the combined technique was 241.1±68.5 N/mm and 340.8±45.3 N/mm, respectively (p=0.012). In the clinical study, the mean clinical score at final follow-up was 28.1 points. Augmentation of separate vertical wiring with cerclage wire provides enough strength for protected early exercise of the knee joint and uneventful healing.

  18. Semi-rigid single hook localization the best method for localizing ground glass opacities during video-assisted thoracoscopic surgery: re-aerated swine lung experimental and primary clinical results

    PubMed Central

    Zhao, Guang; Sun, Long; Geng, Guojun; Liu, Hongming; Li, Ning; Liu, Suhuan; Hao, Bing

    2017-01-01

    Background The aim of this study was to compare the effects of currently available preoperative localization methods, including semi-rigid single hook-wire, double-thorn hook-wire, and microcoil, in localizing the pulmonary nodules, thus to select the best technology to assist video-assisted thoracoscopic surgery (VATS) for small ground glass opacities (GGO). Methods Preoperative CT-guided localizing techniques including semi-rigid single hook-wire, double-thorn hook-wire and microcoil were used in re-aerated fresh swine lung for location experiments. The advantages and drawbacks of the three positioning technologies were compared, and then the most optimal technique was used in patients with GGO. Technical success and post-operative complications were used as primary endpoints. Results All three localizing techniques were successfully performed in the re-aerated fresh swine lung. The median tractive force of semi-rigid single hook wire, double-thorn hook wire and microcoil were 6.5, 4.85 and 0.2 N, which measured by a spring dynamometer. The wound sizes in the superficial pleura, caused by unplugging the needles, were 2 mm in double-thorn hook wire, 1 mm in semi-rigid single hook and 1 mm in microcoil, respectively. In patients with GGOs, the semi-rigid hook wires localizations were successfully performed, without any complication that need to be intervened. Dislodgement was reported in one patient before VATS. No major complications related to the preoperative hook wire localization and VATS were observed. Conclusions We found from our localization experiments in the swine lung that, among the commonly used three localization methods, semi-rigid hook wire showed the best operability and practicability than double-thorn hook wire and microcoil. Preoperative localization of small pulmonary nodules with single semi-rigid hook wire system shows a high success rate, acceptable utility and especially low dislodgement in VATS. PMID:29312722

  19. Manipulating flexible parts using a teleoperated system with time delay: An experiment

    NASA Technical Reports Server (NTRS)

    Kotoku, T.; Takamune, K.; Tanie, K.; Komoriya, K.; Matsuhira, N.; Asakura, M.; Bamba, H.

    1994-01-01

    This paper reports experiments involving the handling of flexible parts (e.g. wires) when using a teleoperated system with time delay. The task is principally a peg-in-hole task involving the wrapping of a wire around two posts on the task-board. It is difficult to estimate the effects of the flexible parts; therefore, on-line teleoperation is indispensable for this class of unpredictable task. We first propose a teleoperation system based on the predictive image display, then describe an experimental teleoperation testbed with a four second transmission time delay. Finally, we report on wire handling operations that were performed to evaluate the performance of this system. Those experiments will contribute to future advanced experiments for the MITI ETS-7 mission.

  20. Calibration, Data Acquisition, and Post Analysis of Turbulent Fluid Flow in a Calibration Jet Using Hot-wire Anemometry

    NASA Technical Reports Server (NTRS)

    Moreno, Michelle

    2004-01-01

    The Turbine Branch concentrates on the following areas: Computational Fluid Dynamics (CFD), and implementing experimental procedures to obtain physical modeling data. Hot-wire Anemometry is a valuable tool for obtaining physical modeling data. Hot-wire Anemometry is likely to remain the principal research tool for most turbulent air/gas flow studies. The Hot-wire anemometer consists of a fine wire heated by electric current. When placed in a fluid stream, the hot-wire loses heat to the fluid by forced convection. In forced convection, energy transfer is due to molecular motion imposed by an extraneous force moving fluid parcels. When the hot-wire is in "equilibrium", the rate of heat input to the wire is equal to the rate of heat loss at the wire ends. The equality between heat input and heat loss is the basis for King s equation, which relates the electrical parameters of the hot-wire to the flow parameters of the fluid. Hot-wire anemometry is based on convective heat transfer from a heated wire element placed in a fluid flow. Any change in the fluid flow condition that affects the heat transfer from the heated element will be detected virtually instantaneously by a constant-temperature Hot-wire anemometry system. The system implemented for this research is the IFA 300. The system is a fully-integrated, thermal anemometer-based system that measures mean and fluctuating velocity components in air, water, and other fluids. It also measures turbulence and makes localized temperature measurements. A constant-temperature anemometer is a bridge and amplifier circuit that controls a tiny wire at constant temperature. As a fluid flow passes over the heated sensor, the amplifier senses the bridge off-balance and adjusts the voltage to the top of the bridge, keeping the bridge in balance. The voltage on top of the bridge can then be related to the velocity of the flow. The bridge voltage is sensitive to temperature as well as velocity and so the built-in thermocouple circuit can be attached to a thermocouple that can measure the fluid temperature. Additional information is included in the original extended abstract.

  1. Underwater Acoustic Source Localisation Among Blind and Sighted Scuba Divers: Comparative study.

    PubMed

    Cambi, Jacopo; Livi, Ludovica; Livi, Walter

    2017-05-01

    Many blind individuals demonstrate enhanced auditory spatial discrimination or localisation of sound sources in comparison to sighted subjects. However, this hypothesis has not yet been confirmed with regards to underwater spatial localisation. This study therefore aimed to investigate underwater acoustic source localisation among blind and sighted scuba divers. This study took place between February and June 2015 in Elba, Italy, and involved two experimental groups of divers with either acquired (n = 20) or congenital (n = 10) blindness and a control group of 30 sighted divers. Each subject took part in five attempts at an under-water acoustic source localisation task, in which the divers were requested to swim to the source of a sound originating from one of 24 potential locations. The control group had their sight obscured during the task. The congenitally blind divers demonstrated significantly better underwater sound localisation compared to the control group or those with acquired blindness ( P = 0.0007). In addition, there was a significant correlation between years of blindness and underwater sound localisation ( P <0.0001). Congenital blindness was found to positively affect the ability of a diver to recognise the source of a sound in an underwater environment. As the correct localisation of sounds underwater may help individuals to avoid imminent danger, divers should perform sound localisation tests during training sessions.

  2. Demonstration and Validation of Materials for Corrosion-Resistant Fencing and Guard Railings in Aggressive Climates

    DTIC Science & Technology

    2015-10-01

    Treat Island, ME Constant Exposure Period (hours) Area (cm2) Pretest Weight (g) Post - Test Weight (g) Mass Loss (grams) Density in (g/cm3...2.3 Coupon monitoring and post -exposure lab testing ........................................ 17 3 Discussion... test sections installed at the FRF. .............................................................. 11 Figure 9. Profile of wire coupons on ASTM G7 rack

  3. Interstitial radiation therapy for carcinoma of the penis using iridium 192 wires: the Henri Mondor experience (1970-1979)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mazeron, J.J.; Langlois, D.; Lobo, P.A.

    1984-10-01

    From 1970 to 1979, a group of 50 patients was treated for squamous cell carcinoma of the penis by interstitial irradiation using an afterloading technique and iridium 192 wires. The group included 9 patients with T1 tumors, 27 with T2 tumors, and 14 with T3 tumors. Forty-five patients presented with no metastatic inguinal nodes (NO), 3 patients with N1 nodes, and 2 patients had N3 nodes. After treatment, 11 patients (1 T1, 6 T2 and 4 T3) developed local recurrences. Three patients developed post-therapeutic necrosis which necessitated partial amputation in 2 cases. Eight patients developed post-therapeutic urethral stenosis, which requiredmore » surgical treatment in three of the cases. Twenty-one percent of the patients died of their disease. The authors advocate interstitial irradiation using iridium 192 wires for the treatment of non-infiltrating or moderately infiltrating squamous cell carcinoma of the penis in which the largest dimension does no exceed 4 cm. When regular follow-up can be assurred, it is reasonable to forgo prophylactic treatment of the inguinal nodes in patients presenting without groin metastasis.« less

  4. Reliability Assessment and Activation Energy Study of Au and Pd-Coated Cu Wires Post High Temperature Aging in Nanoscale Semiconductor Packaging.

    PubMed

    Gan, C L; Hashim, U

    2013-06-01

    Wearout reliability and high temperature storage life (HTSL) activation energy of Au and Pd-coated Cu (PdCu) ball bonds are useful technical information for Cu wire deployment in nanoscale semiconductor device packaging. This paper discusses the influence of wire type on the wearout reliability performance of Au and PdCu wire used in fine pitch BGA package after HTSL stress at various aging temperatures. Failure analysis has been conducted to identify the failure mechanism after HTSL wearout conditions for Au and PdCu ball bonds. Apparent activation energies (Eaa) of both wire types are investigated after HTSL test at 150 °C, 175 °C and 200 °C aging temperatures. Arrhenius plot has been plotted for each ball bond types and the calculated Eaa of PdCu ball bond is 0.85 eV and 1.10 eV for Au ball bond in 110 nm semiconductor device. Obviously Au ball bond is identified with faster IMC formation rate with IMC Kirkendall voiding while PdCu wire exhibits equivalent wearout and or better wearout reliability margin compare to conventional Au wirebond. Lognormal plots have been established and its mean to failure (t 50 ) have been discussed in this paper.

  5. Numerical and experimental analysis of inhomogeneities in SMA wires induced by thermal boundary conditions

    NASA Astrophysics Data System (ADS)

    Furst, Stephen J.; Crews, John H.; Seelecke, Stefan

    2012-11-01

    Published data on NiTi wire tensile tests display a surprising variety of results even though the same material has been studied. Hysteresis shapes can be observed that range from box- to cigar-like. In some cases, the variation may be the result of different post-fabrication treatment, such as annealing or cold working procedures. However, oftentimes local data are generated from average stress/strain concepts on the basis of global force and end displacement measurements. It is well known among experimentalists that this has a smoothening effect on data, but there is an additional, less well-known mechanism at work as well. This effect is due to thermomechanical coupling and the thermal boundary condition at the ends of the wires, and it manifests itself in a strong data dependence on the length of the employed specimen. This paper illustrates the effects of a thermal boundary layer in a 1D wire by means of an experimental study combined with a simulation based on the fully coupled momentum and energy balance equations. The system is modeled using COMSOL FEA software to simulate the distribution of strain, temperature, resistivity, and phase fractions. The local behavior is then integrated over the length of the wire to predict the expected behavior of the bulk wire as observed at its endpoints. Then, simulations are compared with results from a tensile test of a 100 mum diameter Dynalloy Flexinol wire between two large, steel clamps. Each step of the tensile test experiment is carefully controlled and then simulated via the boundary and initial conditions of the model. The simulated and experimental results show how the thermal boundary layer affects different length SMA wires and how the inhomogeneity prevents transition to austenite at the wire endpoints. Accordingly, shorter wires tend to be softer (more martensitic) than longer wires and exhibit a large reduction in recoverable strain because a larger percentage of their total length is impacted by the thermal boundary.

  6. Separate Vertical Wiring for the Fixation of Comminuted Fractures of the Inferior Pole of the Patella

    PubMed Central

    Song, Hyung Keun; Yoo, Je Hyun; Byun, Young Soo

    2014-01-01

    Purpose Among patients over 50 years of age, separate vertical wiring alone may be insufficient for fixation of fractures of the inferior pole of the patella. Therefore, mechanical and clinical studies were performed in patients over the age of 50 to test the strength of augmentation of separate vertical wiring with cerclage wire (i.e., combined technique). Materials and Methods Multiple osteotomies were performed to create four-part fractures in the inferior poles of eight pairs of cadaveric patellae. One patella from each pair was fixed with the separate wiring technique, while the other patella was fixed with a combined technique. The ultimate load to failure and stiffness of the fixation were subsequently measured. In a clinical study of 21 patients (average age of 64 years), comminuted fractures of the inferior pole of the patellae were treated using the combined technique. Operative parameters were recorded from which post-operative outcomes were evaluated. Results For cadaveric patellae, whose mean age was 69 years, the mean ultimate loads to failure for the separate vertical wiring technique and the combined technique were 216.4±72.4 N and 324.9±50.6 N, respectively (p=0.012). The mean stiffness for the separate vertical wiring technique and the combined technique was 241.1±68.5 N/mm and 340.8±45.3 N/mm, respectively (p=0.012). In the clinical study, the mean clinical score at final follow-up was 28.1 points. Conclusion Augmentation of separate vertical wiring with cerclage wire provides enough strength for protected early exercise of the knee joint and uneventful healing. PMID:24719149

  7. En-masse retraction with a preformed nickel-titanium and stainless steel archwire assembly and temporary skeletal anchorage devices without posterior bonding

    PubMed Central

    Jee, Jeong-Hyun; Ahn, Hyo-Won; Seo, Kyung-Won; Kook, Yoon-Ah; Chung, Kyu-Rhim; Nelson, Gerald

    2014-01-01

    Objective To evaluate the therapeutic effects of a preformed assembly of nickel-titanium (NiTi) and stainless steel (SS) archwires (preformed C-wire) combined with temporary skeletal anchorage devices (TSADs) as the sole source of anchorage and to compare these effects with those of a SS version of C-wire (conventional C-wire) for en-masse retraction. Methods Thirty-one adult female patients with skeletal Class I or II dentoalveolar protrusion, mild-to-moderate anterior crowding (3.0-6.0 mm), and stable Class I posterior occlusion were divided into conventional (n = 15) and preformed (n = 16) C-wire groups. All subjects underwent first premolar extractions and en-masse retraction with pre-adjusted edgewise anterior brackets, the assigned C-wire, and maxillary C-tubes or C-implants; bonded mesh-tube appliances were used in the mandibular dentition. Differences in pretreatment and post-retraction measurements of skeletal, dental, and soft-tissue cephalometric variables were statistically analyzed. Results Both groups showed full retraction of the maxillary anterior teeth by controlled tipping and space closure without altered posterior occlusion. However, the preformed C-wire group had a shorter retraction period (by 3.2 months). Furthermore, the maxillary molars in this group showed no significant mesialization, mesial tipping, or extrusion; some mesialization and mesial tipping occurred in the conventional C-wire group. Conclusions Preformed C-wires combined with maxillary TSADs enable simultaneous leveling and space closure from the beginning of the treatment without maxillary posterior bonding. This allows for faster treatment of dentoalveolar protrusion without unwanted side effects, when compared with conventional C-wire, evidencing its clinical expediency. PMID:25309863

  8. Underwater Acoustic Source Localisation Among Blind and Sighted Scuba Divers

    PubMed Central

    Cambi, Jacopo; Livi, Ludovica; Livi, Walter

    2017-01-01

    Objectives Many blind individuals demonstrate enhanced auditory spatial discrimination or localisation of sound sources in comparison to sighted subjects. However, this hypothesis has not yet been confirmed with regards to underwater spatial localisation. This study therefore aimed to investigate underwater acoustic source localisation among blind and sighted scuba divers. Methods This study took place between February and June 2015 in Elba, Italy, and involved two experimental groups of divers with either acquired (n = 20) or congenital (n = 10) blindness and a control group of 30 sighted divers. Each subject took part in five attempts at an under-water acoustic source localisation task, in which the divers were requested to swim to the source of a sound originating from one of 24 potential locations. The control group had their sight obscured during the task. Results The congenitally blind divers demonstrated significantly better underwater sound localisation compared to the control group or those with acquired blindness (P = 0.0007). In addition, there was a significant correlation between years of blindness and underwater sound localisation (P <0.0001). Conclusion Congenital blindness was found to positively affect the ability of a diver to recognise the source of a sound in an underwater environment. As the correct localisation of sounds underwater may help individuals to avoid imminent danger, divers should perform sound localisation tests during training sessions. PMID:28690888

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dawson, P., E-mail: philip.dawson@manchester.ac.uk; Schulz, S.; Oliver, R. A.

    In this paper, we compare and contrast the experimental data and the theoretical predictions of the low temperature optical properties of polar and nonpolar InGaN/GaN quantum well structures. In both types of structure, the optical properties at low temperatures are governed by the effects of carrier localisation. In polar structures, the effect of the in-built electric field leads to electrons being mainly localised at well width fluctuations, whereas holes are localised at regions within the quantum wells, where the random In distribution leads to local minima in potential energy. This leads to a system of independently localised electrons and holes.more » In nonpolar quantum wells, the nature of the hole localisation is essentially the same as the polar case but the electrons are now coulombically bound to the holes forming localised excitons. These localisation mechanisms are compatible with the large photoluminescence linewidths of the polar and nonpolar quantum wells as well as the different time scales and form of the radiative recombination decay curves.« less

  10. A new test method for the assessment of the arc tracking properties of wire insulation in air, oxygen enriched atmospheres and vacuum

    NASA Technical Reports Server (NTRS)

    Koenig, Dieter

    1994-01-01

    Development of a new test method suitable for the assessment of the resistance of aerospace cables to arc tracking for different specific environmental and network conditions of spacecraft is given in view-graph format. The equipment can be easily adapted for tests at different realistic electrical network conditions incorporating circuit protection and the test system works equally well whatever the test atmosphere. Test results confirm that pure Kapton insulated wire has bad arcing characteristics and ETFE insulated wire is considerably better in air. For certain wires, arc tracking effects are increased at higher oxygen concentrations and significantly increased under vacuum. All tests on different cable insulation materials and in different environments, including enriched oxygen atmospheres, resulted in a more or less rapid extinguishing of all high temperature effects at the beginning of the post-test phase. In no case was a self-maintained fire initiated by the arc.

  11. Toxic shock syndrome post open reduction and Kirschner wire fixation of a humeral lateral condyle fracture.

    PubMed

    Chan, Yuen; Selvaratnam, Veenesh; Garg, Neeraj

    2015-08-11

    Use of Kirschner wires (K-wires) is the most common method of fracture stabilisation in lateral condyle fracture fixation in children. We report a case of toxic shock syndrome (TSS) following an open reduction and internal fixation using K-wires for a humeral lateral condyle fracture in a 5-year-old girl. TSS is a toxin-mediated multisystem illness. It typically presents with shock and it is most often attributed to toxin-producing strains of Staphylococcus aureus and Streptococcus pyogenes. It can lead to multiorgan failure and, ultimately, death. It is important to be aware of TSS, as it can present within any setting. Patients often have non-specific symptoms and their condition can worsen rapidly. TSS postorthopaedic surgery is rare; however, due to the serious nature of this disease, it is important to promptly recognise and diagnose TSS, and to ensure appropriate treatment is started without delay. 2015 BMJ Publishing Group Ltd.

  12. Arthroscopic Pullout Fixation for a Small and Comminuted Avulsion Fracture of the Posterior Cruciate Ligament from the Tibia

    PubMed Central

    Nakagawa, Shuji; Arai, Yuji; Hara, Kunio; Inoue, Hiroaki; Hino, Manabu; Kubo, Toshikazu

    2017-01-01

    We describe a patient who underwent arthroscopic pullout fixation for a posterior cruciate ligament (PCL) avulsion fracture. A 46-year-old female, injured in a fall while riding a motorcycle, was diagnosed with a right knee PCL tibial attachment avulsion fracture and underwent arthroscopic osteosynthesis. A Kirschner wire was drilled to a point just medial to the medial border of the anterior tibial bony bed. A suture wire was folded into a loop and introduced into the posteromedial compartment via the bone tunnel. A fixation thread was inserted from the posteromedial portal, through the medial and lateral loop wires, and into the posteromedial compartment. The lateral and medial loop wires attached to the thread were pulled to the outside, and the thread was fixed onto the tibia. Three months post-surgery, she returned to her job. This procedure represents a minimally invasive method of treating avulsion fractures of the tibial attachment of the PCL. PMID:29172392

  13. Vibrating-Wire, Supercooled Liquid Water Content Sensor Calibration and Characterization Progress

    NASA Technical Reports Server (NTRS)

    King, Michael C.; Bognar, John A.; Guest, Daniel; Bunt, Fred

    2016-01-01

    NASA conducted a winter 2015 field campaign using weather balloons at the NASA Glenn Research Center to generate a validation database for the NASA Icing Remote Sensing System. The weather balloons carried a specialized, disposable, vibrating-wire sensor to determine supercooled liquid water content aloft. Significant progress has been made to calibrate and characterize these sensors. Calibration testing of the vibrating-wire sensors was carried out in a specially developed, low-speed, icing wind tunnel, and the results were analyzed. The sensor ice accretion behavior was also documented and analyzed. Finally, post-campaign evaluation of the balloon soundings revealed a gradual drift in the sensor data with increasing altitude. This behavior was analyzed and a method to correct for the drift in the data was developed.

  14. Proteomics profiling of interactome dynamics by colocalisation analysis (COLA).

    PubMed

    Mardakheh, Faraz K; Sailem, Heba Z; Kümper, Sandra; Tape, Christopher J; McCully, Ryan R; Paul, Angela; Anjomani-Virmouni, Sara; Jørgensen, Claus; Poulogiannis, George; Marshall, Christopher J; Bakal, Chris

    2016-12-20

    Localisation and protein function are intimately linked in eukaryotes, as proteins are localised to specific compartments where they come into proximity of other functionally relevant proteins. Significant co-localisation of two proteins can therefore be indicative of their functional association. We here present COLA, a proteomics based strategy coupled with a bioinformatics framework to detect protein-protein co-localisations on a global scale. COLA reveals functional interactions by matching proteins with significant similarity in their subcellular localisation signatures. The rapid nature of COLA allows mapping of interactome dynamics across different conditions or treatments with high precision.

  15. Site-specific differences of insulin action in adipose tissue derived from normal prepubertal children.

    PubMed

    Grohmann, Malcolm; Stewart, Claire; Welsh, Gavin; Hunt, Linda; Tavaré, Jeremy; Holly, Jeff; Shield, Julian; Sabin, Matt; Crowne, Elizabeth

    2005-08-15

    Body fat distribution determines obesity-related morbidity in adults but little is known of the aetiology or pathophysiology in children. This study investigates differences in insulin-mediated metabolism in primary cell cultures of subcutaneous and visceral preadipocytes derived from prepubertal children. The impact of differentiation and responses to TNFalpha exposure was also investigated. Proliferation rates were greater in subcutaneous versus visceral preadipocytes (41 h3 versus 69 h4; P=0.008). Insulin caused a dose-dependent increase in GSK-3 phosphorylation and an increase in MAPK phosphorylation over time, with increased sensitivity in subcutaneous preadipocytes. Post-differentiation, dose-dependent increases in GSK-3 phosphorylation were maintained, while MAPK phosphorylation was identical in both subtypes. No changes were observed in insulin receptor abundance pre-/post-differentiation. GLUT4 abundance was significantly increased in visceral versus subcutaneous adipocytes by 76(4)%; P=0.03), coincidental with increased insulin-stimulated 2-deoxy-glucose transport (+150(26)% versus +79(10)%; P=0.014) and further elevated by acute exposure to TNFalpha (+230(52)%; P=0.019 versus +123(24)%; P=0.025, respectively). TNFalpha also significantly increased basal glucose transport rates (+44(14)%; P=0.006 versus +34(11)%; P=0.007) and GLUT1 localisation to the plasma membrane. These data establish site-specific differences in subcutaneous and visceral fat cells from children. Responses to insulin varied with differentiation and TNFalpha exposure in the two depots, consistent with parallel changes in GLUT1/4 abundance and localisation.

  16. Methods for implantation of micro-wire bundles and optimization of single/multiunit recordings from human mesial temporal lobe

    PubMed Central

    Misra, A; Burke, JF; Ramayya, A; Jacobs, J; Sperling, MR; Moxon, KA; Kahana, MJ; Evans, JJ; Sharan, AD

    2014-01-01

    Objective The authors report methods developed for the implantation of micro-wire bundles into mesial temporal lobe structures and subsequent single neuron recording in epileptic patients undergoing in-patient diagnostic monitoring. This is done with the intention of lowering the perceived barriers to routine single neuron recording from deep brain structures in the clinical setting. Approach Over a 15 month period, 11 patients were implanted with platinum micro-wire bundles into mesial temporal structures. Protocols were developed for A) monitoring electrode integrity through impedance testing, B) ensuring continuous 24-7 recording, C) localizing micro-wire position and “splay” pattern and D) monitoring grounding and referencing to maintain the quality of recordings. Main Result Five common modes of failure were identified: 1) broken micro-wires from acute tensile force, 2) broken micro-wires from cyclic fatigue at stress points, 3) poor in-vivo micro-electrode separation, 4) motion artifact and 5) deteriorating ground connection and subsequent drop in common mode noise rejection. Single neurons have been observed up to 14 days post implantation and on 40% of micro-wires. Significance Long-term success requires detailed review of each implant by both the clinical and research teams to identify failure modes, and appropriate refinement of techniques while moving forward. This approach leads to reliable unit recordings without prolonging operative times, which will help increase the availability and clinical viability of human single neuron data. PMID:24608589

  17. Localised boundary air layer and clothing evaporative resistances for individual body segments.

    PubMed

    Wang, Faming; del Ferraro, Simona; Lin, Li-Yen; Sotto Mayor, Tiago; Molinaro, Vincenzo; Ribeiro, Miguel; Gao, Chuansi; Kuklane, Kalev; Holmér, Ingvar

    2012-01-01

    Evaporative resistance is an important parameter to characterise clothing thermal comfort. However, previous work has focused mainly on either total static or dynamic evaporative resistance. There is a lack of investigation of localised clothing evaporative resistance. The objective of this study was to study localised evaporative resistance using sweating thermal manikins. The individual and interaction effects of air and body movements on localised resultant evaporative resistance were examined in a strict protocol. The boundary air layer's localised evaporative resistance was investigated on nude sweating manikins at three different air velocity levels (0.18, 0.48 and 0.78 m/s) and three different walking speeds (0, 0.96 and 1.17 m/s). Similarly, localised clothing evaporative resistance was measured on sweating manikins at three different air velocities (0.13, 0.48 and 0.70 m/s) and three walking speeds (0, 0.96 and 1.17 m/s). Results showed that the wind speed has distinct effects on local body segments. In contrast, walking speed brought much more effect on the limbs, such as thigh and forearm, than on body torso, such as back and waist. In addition, the combined effect of body and air movement on localised evaporative resistance demonstrated that the walking effect has more influence on the extremities than on the torso. Therefore, localised evaporative resistance values should be provided when reporting test results in order to clearly describe clothing local moisture transfer characteristics. Localised boundary air layer and clothing evaporative resistances are essential data for clothing design and assessment of thermal comfort. A comprehensive understanding of the effects of air and body movement on localised evaporative resistance is also necessary by both textile and apparel researchers and industry.

  18. Detection of Aβ plaque-associated astrogliosis in Alzheimer's disease brain by spectroscopic imaging and immunohistochemistry† †Electronic supplementary information (ESI) available. See DOI: 10.1039/c7an01747b

    PubMed Central

    Tamagnini, Francesco; Jeynes, J. Charles G.; Mattana, Sara; Swift, Imogen; Nallala, Jayakrupakar; Hancock, Jane; Brown, Jonathan T.; Randall, Andrew D.; Stone, Nick

    2018-01-01

    Recent work using micro-Fourier transform infrared (μFTIR) imaging has revealed that a lipid-rich layer surrounds many plaques in post-mortem Alzheimer's brain. However, the origin of this lipid layer is not known, nor is its role in the pathogenesis of Alzheimer's disease (AD). Here, we studied the biochemistry of plaques in situ using a model of AD. We combined FTIR, Raman and immunofluorescence images, showing that astrocyte processes co-localise with the lipid ring surrounding many plaques. We used μFTIR imaging to rapidly measure chemical signatures of plaques over large fields of view, and selected plaques for higher resolution analysis with Raman microscopy. Raman maps showed similar lipid rings and dense protein cores as in FTIR images, but also revealed cell bodies. We confirmed the presence of plaques using amylo-glo staining, and detected astrocytes using immunohistochemistry, revealing astrocyte co-localisation with lipid rings. This work is important because it correlates biochemical changes surrounding the plaque with the biological process of astrogliosis. PMID:29230441

  19. Neurotrophin gene therapy for sustained neural preservation after deafness.

    PubMed

    Atkinson, Patrick J; Wise, Andrew K; Flynn, Brianna O; Nayagam, Bryony A; Hume, Clifford R; O'Leary, Stephen J; Shepherd, Robert K; Richardson, Rachael T

    2012-01-01

    The cochlear implant provides auditory cues to profoundly deaf patients by electrically stimulating the residual spiral ganglion neurons. These neurons, however, undergo progressive degeneration after hearing loss, marked initially by peripheral fibre retraction and ultimately culminating in cell death. This research aims to use gene therapy techniques to both hold and reverse this degeneration by providing a sustained and localised source of neurotrophins to the deafened cochlea. Adenoviral vectors containing green fluorescent protein, with or without neurotrophin-3 and brain derived neurotrophic factor, were injected into the lower basal turn of scala media of guinea pigs ototoxically deafened one week prior to intervention. This single injection resulted in localised and sustained gene expression, principally in the supporting cells within the organ of Corti. Guinea pigs treated with adenoviral neurotrophin-gene therapy had greater neuronal survival compared to contralateral non-treated cochleae when examined at 7 and 11 weeks post injection. Moreover; there was evidence of directed peripheral fibre regrowth towards cells expressing neurotrophin genes after both treatment periods. These data suggest that neurotrophin-gene therapy can provide sustained protection of spiral ganglion neurons and peripheral fibres after hearing loss.

  20. The accuracy of colonoscopic localisation of colorectal tumours: a prospective, multi-centred observational study.

    PubMed

    Johnstone, M S; Moug, S J

    2014-05-01

    Colonoscopy is essential for accurate pre-operative colorectal tumour localisation, but its accuracy for localisation remains undetermined due to limitations of previous work. This study aimed to establish the accuracy of colonoscopic localisation and to determine how frequently inaccuracy results in altered surgical management. A prospective, multi-centred, powered observational study recruited 79 patients with colorectal tumours that underwent curative surgical resection. Patient and colonoscopic factors were recorded. Pre-operative colonoscopic and radiological lesion localisations were compared to intra-operative localisation using pre-defined anatomical bowel segments to determine accuracy, with changes in planned surgical management documented. Colonoscopy accurately located the colorectal tumour in 64/79 patients (81%). Five out of 15 inaccurately located patients required on-table alteration in planned surgical management. Pre-operative imaging was unable to visualise the primary tumour in 23.1% of cases, a finding that was more prevalent amongst bowel screener patients compared to symptomatic patients (45.8% vs. 13%; p = 0.003). Colonoscopic lesion localisation is inaccurate in 19.0% of cases and occurred throughout the colon with a change in on-table surgical management in 6.3%. With CT unable to visualise lesions in just under a quarter of cases, particularly in the screening population, preoperative localisation is heavily reliant on colonoscopy.

  1. Management of symptomatic vertebral haemangioma in a resource challenged environment.

    PubMed

    Adeolu, Augustine A; Balogun, James A; Adeleye, Amos O; Adeoye, Peter O; Okolo, Clement A; Ogbole, Godwin I

    2010-07-01

    Vertebral haemangiomas are benign lesions and often asymptomatic. They are more common in the thoracic spine where they may become symptomatic with varying presentations. We present two teenage girls who presented with progressive, nontraumatic paraparesis with no background history of chronic cough or underlying medical illness. The radiologic investigations were suggestive of vertebral haemangiomas of the thoracic spine. They had surgery: transthoracic approach with corpectomy and fusion with iliac crest autograft. The posterior stabilisation in the first patient was with Rush nails and circlage wire and only circlage wire in the second patient. The first patient's post-operative recovery was complicated by graft extrusion necessitating re-opening thoracotomy and graft replacement. They are, however, both ambulant at discharge and have remained so 13 and 15 months post-surgery. We have presented two cases with rewarding outcomes in the face of 'adaptive' instrumentation due to limited resources.

  2. A hybrid deterministic-probabilistic approach to model the mechanical response of helically arranged hierarchical strands

    NASA Astrophysics Data System (ADS)

    Fraldi, M.; Perrella, G.; Ciervo, M.; Bosia, F.; Pugno, N. M.

    2017-09-01

    Very recently, a Weibull-based probabilistic strategy has been successfully applied to bundles of wires to determine their overall stress-strain behaviour, also capturing previously unpredicted nonlinear and post-elastic features of hierarchical strands. This approach is based on the so-called "Equal Load Sharing (ELS)" hypothesis by virtue of which, when a wire breaks, the load acting on the strand is homogeneously redistributed among the surviving wires. Despite the overall effectiveness of the method, some discrepancies between theoretical predictions and in silico Finite Element-based simulations or experimental findings might arise when more complex structures are analysed, e.g. helically arranged bundles. To overcome these limitations, an enhanced hybrid approach is proposed in which the probability of rupture is combined with a deterministic mechanical model of a strand constituted by helically-arranged and hierarchically-organized wires. The analytical model is validated comparing its predictions with both Finite Element simulations and experimental tests. The results show that generalized stress-strain responses - incorporating tension/torsion coupling - are naturally found and, once one or more elements break, the competition between geometry and mechanics of the strand microstructure, i.e. the different cross sections and helical angles of the wires in the different hierarchical levels of the strand, determines the no longer homogeneous stress redistribution among the surviving wires whose fate is hence governed by a "Hierarchical Load Sharing" criterion.

  3. Fracture strength of different soldered and welded orthodontic joining configurations with and without filling material.

    PubMed

    Bock, Jens Johannes; Bailly, Jacqueline; Gernhardt, Christian Ralf; Fuhrmann, Robert Andreas Werner

    2008-01-01

    The aim of this study was to compare the mechanical strength of different joints made by conventional brazing, TIG and laser welding with and without filling material. Five standardized joining configurations of orthodontic wire in spring hard quality were used: round, cross, 3 mm length, 9 mm length and 7 mm to orthodontic band. The joints were made by five different methods: brazing, tungsten inert gas (TIG) and laser welding with and without filling material. For the original orthodontic wire and for each kind of joint configuration or connecting method 10 specimens were carefully produced, totalizing 240. The fracture strengths were measured with a universal testing machine (Zwick 005). Data were analyzed by ANOVA (p=0.05) and Bonferroni post hoc test (p=0.05). In all cases, brazing joints were ruptured on a low level of fracture strength (186-407 N). Significant differences between brazing and TIG or laser welding (p<0.05, Bonferroni post hoc test) were found in each joint configuration. The highest fracture strength means were observed for laser welding with filling material and 3 mm joint length (998 N). Using filling materials, there was a clear tendency to higher mean values of fracture strength in TIG and laser welding. However, statistically significant differences were found only in the 9-mm long joints (p<0.05, Bonferroni post hoc test). In conclusion, the fracture strength of welded joints was positively influenced by the additional use of filling material. TIG welding was comparable to laser welding except for the impossibility of joining orthodontic wire with orthodontic band.

  4. FRACTURE STRENGTH OF DIFFERENT SOLDERED AND WELDED ORTHODONTIC JOINING CONFIGURATIONS WITH AND WITHOUT FILLING MATERIAL

    PubMed Central

    Bock, Jens Johannes; Bailly, Jacqueline; Gernhardt, Christian Ralf; Fuhrmann, Robert Andreas Werner

    2008-01-01

    The aim of this study was to compare the mechanical strength of different joints made by conventional brazing, TIG and laser welding with and without filling material. Five standardized joining configurations of orthodontic wire in spring hard quality were used: round, cross, 3 mm length, 9 mm length and 7 mm to orthodontic band. The joints were made by five different methods: brazing, tungsten inert gas (TIG) and laser welding with and without filling material. For the original orthodontic wire and for each kind of joint configuration or connecting method 10 specimens were carefully produced, totalizing 240. The fracture strengths were measured with a universal testing machine (Zwick 005). Data were analyzed by ANOVA (p=0.05) and Bonferroni post hoc test (p=0.05). In all cases, brazing joints were ruptured on a low level of fracture strength (186-407 N). Significant differences between brazing and TIG or laser welding (p<0.05, Bonferroni post hoc test) were found in each joint configuration. The highest fracture strength means were observed for laser welding with filling material and 3 mm joint length (998 N). Using filling materials, there was a clear tendency to higher mean values of fracture strength in TIG and laser welding. However, statistically significant differences were found only in the 9-mm long joints (p<0.05, Bonferroni post hoc test). In conclusion, the fracture strength of welded joints was positively influenced by the additional use of filling material. TIG welding was comparable to laser welding except for the impossibility of joining orthodontic wire with orthodontic band. PMID:19089229

  5. Neglected Posterior Dislocation of Hip in Children - A Case Report.

    PubMed

    Pal, Chandra Prakash; Kumar, Deepak; Sadana, Ashwani; Dinkar, Karuna Shankar

    2014-01-01

    Traumatic dislocation of the hip in children is a rare injury. We report the outcome of 2 patients of neglected hip dislocation which were treated by open reduction and internal fixation by k-wires. We treat 2 children both girls (one was of 4 years and other was 7 years of age). In both cases dislocation was unilateral and was not associated with any facture. Both cases were of posterior dislocation. in both cases open reduction and internal fixation was done by k wires. Hip spica was applied post operatively in both cases. The k wire was removed at 3 to 4 weeks. Patients were allowed to bear weight from gradual to full weight bearing after 6 weeks. We conclude that open reduction is a satisfactory treatment for neglected hip dislocation. It prevents not only deformity but also maintains limb length.

  6. Detail of old rain shed (Building No. 43) showing vertical ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Detail of old rain shed (Building No. 43) showing vertical posts on concrete footing with diagonal timber bracing and wire bracing. - Hawaii Volcanoes National Park Water Collection System, Hawaii Volcanoes National Park, Volcano, Hawaii County, HI

  7. Carrier capture efficiency in InGaN/GaN LEDs: Role of high temperature annealing

    NASA Astrophysics Data System (ADS)

    Vinattieri, A.; Batignani, F.; Bogani, F.; Meneghini, M.; Meneghesso, G.; Zanoni, E.; Zhu, D.; Humphreys, C. J.

    2014-02-01

    By means of time integrated (TI), time-resolved (TR) photoluminescence (PL) and PL excitation spectra, we investigate the role of an high temperature post-growth thermal annealing (TA) on a set of InGaN/GaN LED structures with different dislocation densities. We provide evidence of the nature of the radiative recombination from a wide distribution of non-interacting localised states and we show the beneficial effect of thermal annealing in reducing the contribution of non-radiative recombination in the well region.

  8. Investigation of the distribution of localised and extended states in amorphous MoOx

    NASA Astrophysics Data System (ADS)

    Dizayee, Wala; Ying, Minju; Griffin, Jonathan; Alqahtani, Mohammed S.; Buckley, Alastair; Fox, A. Mark; Gehring, Gillian A.

    2018-05-01

    Amorphous films of MoOx have both structural disorder and also chemical disorder for x<3. We have shown that this disorder can introduce localised states in thin films and have shown that the existence of localised states can be deduced from the XPS data that identifies the relevant occupations of different ionisation states of the Mo ions. This effect, which depends on both the oxygen concentration and the method of fabrication, is more important than electron-electron interactions in producing the observed localisation. We have also shown that magneto-optical dichroism is also a powerful technique to determine the energy distribution of localised and delocalised states.

  9. Visual detail about the body modulates tactile localisation biases.

    PubMed

    Margolis, Aaron N; Longo, Matthew R

    2015-02-01

    The localisation of tactile stimuli requires the integration of visual and somatosensory inputs within an internal representation of the body surface and is prone to consistent bias. Joints may play a role in segmenting such internal body representations, and may therefore influence tactile localisation biases, although the nature of this influence remains unclear. Here, we investigate the relationship between conceptual knowledge of joint locations and tactile localisation biases on the hand. In one task, participants localised tactile stimuli applied to the dorsum of their hand. A distal localisation bias was observed in all participants, consistent with previous results. We also manipulated the availability of visual information during this task, to determine whether the absence of this information could account for the distal bias observed here and by Mancini et al. (Neuropsychologia 49:1194-1201, 2011). The observed distal bias increased in magnitude when visual information was restricted, without a corresponding decrease in precision. In a separate task, the same participants indicated, from memory, knuckle locations on a silhouette image of their hand. Analogous distal biases were also seen in the knuckle localisation task. The accuracy of conceptual joint knowledge was not correlated with tactile localisation bias magnitude, although a similarity in observed bias direction suggests that both tasks may rely on a common, higher-order body representation. These results also suggest that distortions of conceptual body representation may be more common in healthy individuals than previously thought.

  10. BrachyView: multiple seed position reconstruction and comparison with CT post-implant dosimetry

    NASA Astrophysics Data System (ADS)

    Alnaghy, S.; Loo, K. J.; Cutajar, D. L.; Jalayer, M.; Tenconi, C.; Favoino, M.; Rietti, R.; Tartaglia, M.; Carriero, F.; Safavi-Naeini, M.; Bucci, J.; Jakubek, J.; Pospisil, S.; Zaider, M.; Lerch, M. L. F.; Rosenfeld, A. B.; Petasecca, M.

    2016-05-01

    BrachyView is a novel in-body imaging system utilising high-resolution pixelated silicon detectors (Timepix) and a pinhole collimator for brachytherapy source localisation. Recent studies have investigated various options for real-time intraoperative dynamic dose treatment planning to increase the quality of implants. In a previous proof-of-concept study, the justification of the pinhole concept was shown, allowing for the next step whereby multiple active seeds are implanted into a PMMA phantom to simulate a more realistic clinical scenario. In this study, 20 seeds were implanted and imaged using a lead pinhole of 400 μ m diameter. BrachyView was able to resolve the seed positions within 1-2 mm of expected positions, which was verified by co-registering with a full clinical post-implant CT scan.

  11. The impact of wire caliber on ERCP outcomes: a multicenter randomized controlled trial of 0.025-inch and 0.035-inch guidewires.

    PubMed

    Bassan, Milan S; Sundaralingam, Praka; Fanning, Scott B; Lau, James; Menon, Jayaram; Ong, Evan; Rerknimitr, Rungsun; Seo, Dong-Wan; Teo, Eng Kiong; Wang, Hsiu-Po; Reddy, D Nageshwar; Goh, Khean Lee; Bourke, Michael J

    2018-06-01

    Wire-guided biliary cannulation has been demonstrated to improve cannulation rates and reduce post-ERCP pancreatitis (PEP), but the impact of wire caliber has not been studied. This study compares successful cannulation rates and ERCP adverse events by using a 0.025-inch and 0.035-inch guidewire. A randomized, single blinded, prospective, multicenter trial at 9 high-volume tertiary-care referral centers in the Asia-Pacific region was performed. Patients with an intact papilla and conventional anatomy who did not have malignancy in the head of the pancreas or ampulla and were undergoing ERCP were recruited. ERCP was performed by using a standardized cannulation algorithm, and patients were randomized to either a 0.025-inch or 0.035-inch guidewire. The primary outcomes of the study were successful wire-guided cannulation and the incidence of PEP. Overall successful cannulation and ERCP adverse events also were studied. A total of 710 patients were enrolled in the study. The primary wire-guided biliary cannulation rate was similar in 0.025-inch and 0.035-inch wire groups (80.7% vs 80.3%; P = .90). The rate of PEP between the 0.025-inch and the 0.035-inch wire groups did not differ significantly (7.8% vs 9.3%; P = .51). No differences were noted in secondary outcomes. Similar rates of successful cannulation and PEP were demonstrated in the use of 0.025-inch and 0.035-inch guidewires. (Clinical trial registration number: NCT01408264.). Copyright © 2018. Published by Elsevier Inc.

  12. Anderson localisation and optical-event horizons in rogue-soliton generation.

    PubMed

    Saleh, Mohammed F; Conti, Claudio; Biancalana, Fabio

    2017-03-06

    We unveil the relation between the linear Anderson localisation process and nonlinear modulation instability. Anderson localised modes are formed in certain temporal intervals due to the random background noise. Such localised modes seed the formation of solitary waves that will appear during the modulation instability process at those preferred intervals. Afterwards, optical-event horizon effects between dispersive waves and solitons produce an artificial collective acceleration that favours the collision of solitons, which could eventually lead to a rogue-soliton generation.

  13. Epidemiological Differences Between Localised and Non-Localised Low Back Pain

    PubMed Central

    Coggon, David; Ntani, Georgia; Walker-Bone, Karen; Palmer, Keith T; Felli, Vanda E; Harari, Raul; Barrero, Lope H; Felknor, Sarah A.; Gimeno, David; Cattrell, Anna; Vargas-Prada, Sergio; Bonzini, Matteo; Solidaki, Eleni; Merisalu, Eda; Habib, Rima R.; Sadeghian, Farideh; Kadir, M Masood; Warnakulasuriya, Sudath SP; Matsudaira, Ko; Nyantumbu, Busisiwe; Sim, Malcolm R; Harcombe, Helen; Cox, Ken; Sarquis, Leila M M; Marziale, Maria H; Harari, Florencia; Freire, Rocio; Harari, Natalia; Monroy, Magda V; Quintana, Leonardo A; Rojas, Marianela; Harris, E Clare; Serra, Consol; Martinez, J Miguel; Delclos, George; Benavides, Fernando G; Carugno, Michele; Ferrario, Marco M; Pesatori, Angela C; Chatzi, Leda; Bitsios, Panos; Kogevinas, Manolis; Oha, Kristel; Freimann, Tiina; Sadeghian, Ali; Peiris-John, Roshini J; Sathiakumar, Nalini; Wickremasinghe, A Rajitha; Yoshimura, Noriko; Kelsall, Helen L; Hoe, Victor C W; Urquhart, Donna M; Derrett, Sarah; McBride, David; Herbison, Peter; Gray, Andrew; Salazar Vega, Eduardo J.

    2017-01-01

    Study design Cross-sectional survey with longitudinal follow-up Objectives To test the hypothesis that pain which is localised to the low back differs epidemiologically from that which occurs simultaneously or close in time to pain at other anatomical sites Summary of background data Low back pain (LBP) often occurs in combination with other regional pain, with which it shares similar psychological and psychosocial risk factors. However, few previous epidemiological studies of LBP have distinguished pain that is confined to the low back from that which occurs as part of a wider distribution of pain. Methods We analysed data from a cohort study of musculoskeletal pain and associated disability in 47 occupational groups from 18 countries. Results Among 12,197 subjects at baseline, 609 (4.9%) reported localised LBP in the past month, and 3,820 (31.3%) non-localised LBP. Non-localised LBP was more frequently associated with sciatica in the past month (48.1% vs. 30.0% of cases), occurred on more days in the past month and past year, was more often disabling for everyday activities (64.1% vs. 47.3% of cases), and had more frequently led to medical consultation and sickness absence from work. It was also more often persistent when participants were followed up after a mean of 14 months (65.6% vs. 54.1% of cases). In adjusted Poisson regression analyses, non-localised LBP was differentially associated with female sex, older age, somatising tendency, poor mental health and report of time pressure at work,. There were also marked differences in the relative prevalence of localised and non-localised LBP by occupational group. Conclusions Future epidemiological studies should distinguish where possible between pain that is limited to the low back and LBP which occurs in association with pain at other anatomical locations. PMID:27820794

  14. Development of a prototype of the tele-localisation system in radiotherapy using personal digital assistant via wireless communication.

    PubMed

    Wu, Vincent Wing-Cheung; Tang, Fuk-hay; Cheung, Wai-kwan; Chan, Kit-chi

    2013-02-01

    In localisation of radiotherapy treatment field, the oncologist is present at the simulator to approve treatment details produced by the therapist. Problems may arise if the oncologist is not available and the patient requires urgent treatment. The development of a tele-localisation system is a potential solution, where the oncologist uses a personal digital assistant (PDA) to localise the treatment field on the image sent from the simulator through wireless communication and returns the information to the therapist after his or her approval. Our team developed the first tele-localisation prototype, which consisted of a server workstation (simulator) for the administration of digital imaging and communication in medicine localisation images including viewing and communication with the PDA via a Wi-Fi network; a PDA (oncologist's site) installed with the custom-built programme that synchronises with the server workstation and performs treatment field editing. Trial tests on accuracy and speed of the prototype system were conducted on 30 subjects with the treatment regions covering the neck, skull, chest and pelvis. The average time required in performing the localisation using the PDA was less than 1.5 min, with the blocked field longer than the open field. The transmission speed of the four treatment regions was similar. The average physical distortion of the images was within 4.4% and the accuracy of field size indication was within 5.3%. Compared with the manual method, the tele-localisation system presented with an average deviation of 5.5%. The prototype system fulfilled the planned objectives of tele-localisation procedure with reasonable speed and accuracy. © 2012 The Authors. Journal of Medical Imaging and Radiation Oncology © 2012 The Royal Australian and New Zealand College of Radiologists.

  15. Safe intramedullary fixation of displaced midshaft clavicle fractures with 2.5mm Kirschner wires - technique description and a two-part versus multifragmentary fracture fixation outcome comparison.

    PubMed

    Bakota, Bore; Chan, Gareth; Staresinic, Mario; Rajput, Vishal; Phadnis, Joideep; Korac, Zelimir

    2017-11-01

    The aim of this study was to present a modified Murray and Schwarz 2.5-mm Kirschner wire (K-wire) intramedullary (IM) technique for fixation of displaced midshaft clavicle fractures (DMCF), and to compare the differences in treatment outcome of two-part (Robinson 2B.1) and multifragmentary (Robinson 2B.2) DMCF. A retrospective analysis of 91 patients who underwent IM fixation with a 2.5-mm K-wire for DMCF and had a 1-year post-operative follow-up between 2000 and 2012 was performed. The patients were allocated into two groups: Robinson 2B.1 (n = 64) and Robinson 2B.2 (n = 27). Assessed outcomes were non-union, reoperation rate, wire migration and infection. There was no statistically significant difference in the rate of non-union (2B.1,2B.2; 3.13%, 7.41%; p = 0.365), reoperation (2B.1, 2B.2; 3.13%, 7.41%; p = 0.365), K-wire migration (2B.1, 2B.2; 0.00%, 0.00%; p = 1.00) and clavicle shortening at 12-months (2B.1, 2B.2; 3.13%, 7.41%; p = 0.365). Intramedullary clavicle fixation with a 2.5-mm K-wire is a safe surgical technique. 2B.1 injuries treated with 2.5-mm IM K-wire fixation have relatively improved outcome compared with displaced 2B.2 fractures for both non-union and reoperation rates. There were no occurrences of implant migration with either 2B.1 or 2B.2 injuries, and a non-significant difference in implant irritation was documented with IM K-fixation. The non-union rate with K-wire IM fixation of 2B.1 injuries concords with the published results of other IM devices and thus this technique should be added to the surgeon's armamentarium when considering surgical treatment of such injuries. © 2017 Elsevier Ltd. All rights reserved.

  16. Proteomics profiling of interactome dynamics by colocalisation analysis (COLA)† †Electronic supplementary information (ESI) available. See DOI: 10.1039/c6mb00701e Click here for additional data file. Click here for additional data file.

    PubMed Central

    Sailem, Heba Z.; Kümper, Sandra; Tape, Christopher J.; McCully, Ryan R.; Paul, Angela; Anjomani-Virmouni, Sara; Jørgensen, Claus; Poulogiannis, George; Marshall, Christopher J.

    2017-01-01

    Localisation and protein function are intimately linked in eukaryotes, as proteins are localised to specific compartments where they come into proximity of other functionally relevant proteins. Significant co-localisation of two proteins can therefore be indicative of their functional association. We here present COLA, a proteomics based strategy coupled with a bioinformatics framework to detect protein–protein co-localisations on a global scale. COLA reveals functional interactions by matching proteins with significant similarity in their subcellular localisation signatures. The rapid nature of COLA allows mapping of interactome dynamics across different conditions or treatments with high precision. PMID:27824369

  17. Subcellular mRNA localisation at a glance

    PubMed Central

    Parton, Richard M.; Davidson, Alexander; Davis, Ilan; Weil, Timothy T.

    2014-01-01

    ABSTRACT mRNA localisation coupled to translational regulation provides an important means of dictating when and where proteins function in a variety of model systems. This mechanism is particularly relevant in polarised or migrating cells. Although many of the models for how this is achieved were first proposed over 20 years ago, some of the molecular details are still poorly understood. Nevertheless, advanced imaging, biochemical and computational approaches have started to shed light on the cis-acting localisation signals and trans-acting factors that dictate the final destination of localised transcripts. In this Cell Science at a Glance article and accompanying poster, we provide an overview of mRNA localisation, from transcription to degradation, focusing on the microtubule-dependent active transport and anchoring mechanism, which we will use to explain the general paradigm. However, it is clear that there are diverse ways in which mRNAs become localised and target protein expression, and we highlight some of the similarities and differences between these mechanisms. PMID:24833669

  18. Resonant photoluminescence studies of carrier localisation in c-plane InGaN/GaN quantum well structures

    NASA Astrophysics Data System (ADS)

    Blenkhorn, W. E.; Schulz, S.; Tanner, D. S. P.; Oliver, R. A.; Kappers, M. J.; Humphreys, C. J.; Dawson, P.

    2018-05-01

    In this paper we report on changes in the form of the low temperature (12 K) photoluminescence spectra of an InGaN/GaN quantum well structure as a function of excitation photon energy. As the photon energy is progressively reduced we observe at a critical energy a change in the form of the spectra from one which is determined by the occupation of the complete distribution of hole localisation centres to one which is determined by the resonant excitation of specific localisation sites. This change is governed by an effective mobility edge whereby the photo-excited holes remain localised at their initial energy and are prevented from scattering to other localisation sites. This assignment is confirmed by the results of atomistic tight binding calculations which show that the wave function overlap of the lowest lying localised holes with other hole states is low compared with the overlap of higher lying hole states with other higher lying hole states.

  19. Gene and protein expression and cellular localisation of cytochrome P450 enzymes of the 1A, 2A, 2C, 2D and 2E subfamilies in equine intestine and liver.

    PubMed

    Tydén, Eva; Tjälve, Hans; Larsson, Pia

    2014-10-08

    Among the cytochrome P450 enzymes (CYP), families 1-3 constitute almost half of total CYPs in mammals and play a central role in metabolism of a wide range of pharmaceuticals. This study investigated gene and protein expression and cellular localisation of CYP1A, CYP2A, CYP2C, CYP2D and CYP2E in equine intestine and liver. Real-time polymerase chain reaction (RT-PCR) was used to analyse gene expression, western blot to examine protein expression and immunohistochemical analyses to investigate cellular localisation. CYP1A and CYP2C were the CYPs with the highest gene expression in the intestine and also showed considerable gene expression in the liver. CYP2E and CYP2A showed the highest gene expression in the liver. CYP2E showed moderate intestinal gene expression, whereas that of CYP2A was very low or undetectable. For CYP2D, rather low gene expression levels were found in both intestine and the liver. In the intestine, CYP gene expression levels, except for CYP2E, exhibited patterns resembling those of the proteins, indicating that intestinal protein expression of these CYPs is regulated at the transcriptional level. For CYP2E, the results showed that the intestinal gene expression did not correlate to any visible protein expression, indicating that intestinal protein expression of this CYP is regulated at the post-transcriptional level. Immunostaining of intestine tissue samples showed preferential CYP staining in enterocytes at the tips of intestinal villi in the small intestine. In the liver, all CYPs showed preferential localisation in the centrilobular hepatocytes. Overall, different gene expression profiles were displayed by the CYPs examined in equine intestine and liver. The CYPs present in the intestine may act in concert with those in the liver to affect the oral bioavailability and therapeutic efficiency of substrate drugs. In addition, they may play a role in first-pass metabolism of feed constituents and of herbal supplements used in equine practice.

  20. Etoposide Induces Nuclear Re-Localisation of AID

    PubMed Central

    Lambert, Laurens J.; Walker, Simon; Feltham, Jack; Lee, Heather J.; Reik, Wolf; Houseley, Jonathan

    2013-01-01

    During B cell activation, the DNA lesions that initiate somatic hypermutation and class switch recombination are introduced by activation-induced cytidine deaminase (AID). AID is a highly mutagenic protein that is maintained in the cytoplasm at steady state, however AID is shuttled across the nuclear membrane and the protein transiently present in the nucleus appears sufficient for targeted alteration of immunoglobulin loci. AID has been implicated in epigenetic reprogramming in primordial germ cells and cell fusions and in induced pluripotent stem cells (iPS cells), however AID expression in non-B cells is very low. We hypothesised that epigenetic reprogramming would require a pathway that instigates prolonged nuclear residence of AID. Here we show that AID is completely re-localised to the nucleus during drug withdrawal following etoposide treatment, in the period in which double strand breaks (DSBs) are repaired. Re-localisation occurs 2-6 hours after etoposide treatment, and AID remains in the nucleus for 10 or more hours, during which time cells remain live and motile. Re-localisation is cell-cycle dependent and is only observed in G2. Analysis of DSB dynamics shows that AID is re-localised in response to etoposide treatment, however re-localisation occurs substantially after DSB formation and the levels of re-localisation do not correlate with γH2AX levels. We conclude that DSB formation initiates a slow-acting pathway which allows stable long-term nuclear localisation of AID, and that such a pathway may enable AID-induced DNA demethylation during epigenetic reprogramming. PMID:24324754

  1. Role of intraoperative ultrasound in achieving complete resection of intra-axial solid brain tumours.

    PubMed

    Mari, Abdul Razaque; Shah, Irfanullah; Imran, Muhammed; Ashraf, Junaid

    2014-12-01

    To determine the frequency of completeness of resection for intra-axial solid brain tumours with the help of intra-operative ultrasound to detect residual brain tumour. The cross-sectional study was conducted at the Department of Neurosurgery, Dow University of Health Sciences and Civil Hospital Karachi, from September 2009 to June 2010 and comprised patients with intra-axial solid brain lesion. During operation following standard craniotomy, multi-plane sonographic examination was performed using intra-operative ultrasound for tumour localisation and calculation of dimension, followed by tumour resection in the standard fashion. At the end of tumour resection ultrasound was again used for the detection of any residual tumour. Results of intra-operative ultrasound were compared with post-operative contrast magnetic resonance imaging. Of the 39 cases in which intra-operative ultrasound was performed, 32(82.1%) were males and 7(17.9%) were females, with an overall mean age of 42.6±19.7 years. Intra-operative ultrasonography was able to localise and delineate the tumour in all 39 (100%) cases. It showed no residual tumour in 36 (92.3%) cases, but in 3(7.7%) cases residual tumour was detected. Post-operative contrast enhancing magnetic resonance imaging showed no residual tumour in 35(89.7%) cases and in 4(10.3%) cases residual tumour was detected. The frequency of completely resected intra-axial solid brain tumour was 35(89.7%), while in 4(10.3%) cases incomplete resection was observed. The study concluded that intra-operative ultrasonography has an important role in achieving increased frequency of completely resected intra-axial solid brain tumours.

  2. Evaluation of surface roughness of orthodontic wires by means of atomic force microscopy.

    PubMed

    D'Antò, Vincenzo; Rongo, Roberto; Ametrano, Gianluca; Spagnuolo, Gianrico; Manzo, Paolo; Martina, Roberto; Paduano, Sergio; Valletta, Rosa

    2012-09-01

    To compare the surface roughness of different orthodontic archwires. Four nickel-titanium wires (Sentalloy(®), Sentalloy(®) High Aesthetic, Titanium Memory ThermaTi Lite(®), and Titanium Memory Esthetic(®)), three β-titanium wires (TMA(®), Colored TMA(®), and Beta Titanium(®)), and one stainless-steel wire (Stainless Steel(®)) were considered for this study. Three samples for each wire were analyzed by atomic force microscopy (AFM). Three-dimensional images were processed using Gwiddion software, and the roughness average (Ra), the root mean square (Rms), and the maximum height (Mh) values of the scanned surface profile were recorded. Statistical analysis was performed by one-way analysis of variance (ANOVA) followed by Tukey's post hoc test (P < .05). The Ra, Rms, and Mh values were expressed as the mean ± standard deviation. Among as-received archwires, the Stainless Steel (Ra  =  36.6 ± 5.8; Rms  =  48 ± 7.7; Mh  =  328.1 ± 64) archwire was less rough than the others (ANOVA, P < .05). The Sentalloy High Aesthetic was the roughest (Ra  =  133.5 ± 10.8; Rms  =  165.8 ± 9.8; Mh  =  949.6 ± 192.1) of the archwires. The surface quality of the wires investigated differed significantly. Ion implantation effectively reduced the roughness of TMA. Moreover, Teflon(®)-coated Titanium Memory Esthetic was less rough than was ion-implanted Sentalloy High Aesthetic.

  3. Thermal Transport Model for Heat Sink Design

    NASA Technical Reports Server (NTRS)

    Chervenak, James A.; Kelley, Richard L.; Brown, Ari D.; Smith, Stephen J.; Kilbourne, Caroline a.

    2009-01-01

    A document discusses the development of a finite element model for describing thermal transport through microcalorimeter arrays in order to assist in heat-sinking design. A fabricated multi-absorber transition edge sensor (PoST) was designed in order to reduce device wiring density by a factor of four. The finite element model consists of breaking the microcalorimeter array into separate elements, including the transition edge sensor (TES) and the silicon substrate on which the sensor is deposited. Each element is then broken up into subelements, whose surface area subtends 10 10 microns. The heat capacity per unit temperature, thermal conductance, and thermal diffusivity of each subelement are the model inputs, as are the temperatures of each subelement. Numerical integration using the Finite in Time Centered in Space algorithm of the thermal diffusion equation is then performed in order to obtain a temporal evolution of the subelement temperature. Thermal transport across interfaces is modeled using a thermal boundary resistance obtained using the acoustic mismatch model. The document concludes with a discussion of the PoST fabrication. PoSTs are novel because they enable incident x-ray position sensitivity with good energy resolution and low wiring density.

  4. Evaluating the accuracy of the XVI dual registration tool compared with manual soft tissue matching to localise tumour volumes for post-prostatectomy patients receiving radiotherapy.

    PubMed

    Campbell, Amelia; Owen, Rebecca; Brown, Elizabeth; Pryor, David; Bernard, Anne; Lehman, Margot

    2015-08-01

    Cone beam computerised tomography (CBCT) enables soft tissue visualisation to optimise matching in the post-prostatectomy setting, but is associated with inter-observer variability. This study assessed the accuracy and consistency of automated soft tissue localisation using XVI's dual registration tool (DRT). Sixty CBCT images from ten post-prostatectomy patients were matched using: (i) the DRT and (ii) manual soft tissue registration by six radiation therapists (RTs). Shifts in the three Cartesian planes were recorded. The accuracy of the match was determined by comparing shifts to matches performed by two genitourinary radiation oncologists (ROs). A Bland-Altman method was used to assess the 95% levels of agreement (LoA). A clinical threshold of 3 mm was used to define equivalence between methods of matching. The 95% LoA between DRT-ROs in the superior/inferior, left/right and anterior/posterior directions were -2.21 to +3.18 mm, -0.77 to +0.84 mm, and -1.52 to +4.12 mm, respectively. The 95% LoA between RTs-ROs in the superior/inferior, left/right and anterior/posterior directions were -1.89 to +1.86 mm, -0.71 to +0.62 mm and -2.8 to +3.43 mm, respectively. Five DRT CBCT matches (8.33%) were outside the 3-mm threshold, all in the setting of bladder underfilling or rectal gas. The mean time for manual matching was 82 versus 65 s for DRT. XVI's DRT is comparable with RTs manually matching soft tissue on CBCT. The DRT can minimise RT inter-observer variability; however, involuntary bladder and rectal filling can influence the tools accuracy, highlighting the need for RT evaluation of the DRT match. © 2015 The Royal Australian and New Zealand College of Radiologists.

  5. Electron localisation in static and time-dependent one-dimensional model systems

    NASA Astrophysics Data System (ADS)

    Durrant, T. R.; Hodgson, M. J. P.; Ramsden, J. D.; Godby, R. W.

    2018-02-01

    The most direct signature of electron localisation is the tendency of an electron in a many-body system to exclude other same-spin electrons from its vicinity. By applying this concept directly to the exact many-body wavefunction, we find that localisation can vary considerably between different ground-state systems, and can also be strongly disrupted, as a function of time, when a system is driven by an applied electric field. We use this measure to assess the well-known electron localisation function (ELF), both in its approximate single-particle form (often applied within density-functional theory) and its full many-particle form. The full ELF always gives an excellent description of localisation, but the approximate ELF fails in time-dependent situations, even when the exact Kohn-Sham orbitals are employed.

  6. Expression of nuclear progesterone receptor and progesterone receptor membrane components 1 and 2 in the oviduct of cyclic and pregnant cows during the post-ovulation period

    PubMed Central

    2012-01-01

    Background Progesterone (P4) may modulate oviductal functions to promote early embryo development in cattle. In addition to its nuclear receptor (PR), P4 may mediate its actions through P4 receptor membrane component 1 (PGRMC1) and its relative, PGRMC2. Two successive experiments were undertaken to characterise the expression of PR, PGRMC1 and PGRMC2 in the bovine oviduct during the post-ovulation period, and to relate their expression to the presence of an embryo, the proximity of the CL and to the region of the oviduct. Methods In the first experiment (Exp. I), whole oviduct sections were collected from Holstein cows at Day 1.5, Day 4 and Day 5 post-ovulation (n = 2 cows per stage). The expression of PR, PGRMC1 and PGRMC2 was studied in the ampulla and isthmus by RT-PCR, western-blot and immunohistochemistry. In Exp. II, oviduct epithelial cells were collected from cyclic and pregnant Charolais cows (n = 4 cows per status) at Day 3.5 post-ovulation and mRNA expression of PR, PGRMC1 and PGRMC2 was examined in the ampulla and isthmus by real-time quantitative PCR. Results In Exp. I, PR, PGRMC1 and PGRMC2 were expressed in all oviduct samples. PGRMC1 was mainly localised in the luminal epithelium whereas PR and PGRMC2 were localised in the epithelium as well as in the muscle and stroma layers of the oviduct. The expression was primarily nuclear for PR, primarily cytoplasmic for PGRMC1 and both nuclear and cytoplasmic for PGRMC2. In Exp. II, mRNA levels for PR, PGRMC1 and PGRMC2 were not affected by either the pregnancy status or the side relative to the CL. However, the expression of PR and PGRMC2 varied significantly with the region of the oviduct: PR was more highly expressed in the isthmus whereas PGRMC2 was more highly expressed in the ampulla. Conclusions This is the first evidence of PGRMC2 expression in the bovine oviduct. Our findings suggest that P4 regulates the functions of the bovine oviduct in a region-specific manner and through both classical and non classical pathways during the post-ovulation period. PMID:22958265

  7. Technical success from endovascular aneurysm repair in the post-marketing era: a multicenter prospective trial.

    PubMed

    Naslund, Thomas C; Becker, Stacey Y

    2003-01-01

    Evaluation of post-marketing success with the Ancure Endovascular Graft (AEG) was accomplished by review of a multicenter, prospective trial involving 46 centers and 163 patients. A second cohort of patients (n = 350) treated with the AEG under a controlled-use interval prior to the prospective trial was simultaneously evaluated. Technical success in both groups of patients (96.9% and 97.4%, respectively) was similar to what was reported in pre-market clinical trials. Operative implantation complications unique to the AEG included graft limb stenosis/occlusion in 35.6 and 31.4%, contralateral pull wire being caught on hooks in 33.7 and 28%, failure to seal (type I endoleak) in 17.2 and 18.3%, jacket guard being stuck in 12.9 and 11%, contralateral wire being stuck in 6.8 and 7.1%, high jacket retraction force in 16 and 8.5%, and inability to retract jacket in 1.8 and 0.5% of patients involved in the multicenter trial and controlled-use interval, respectively. One of four patients undergoing conversion in the prospective trial had graft misdeployment as a mode of failure. Three were converted for access failure. The 30-day mortality rate in the prospective trial was 3.7%. Interventions to resolve implantation-related events included stenting, guide catheter manipulations, wire exchanges, and delivery catheter disassembly. These interventions were successful in virtually every case. Open surgical procedures were not needed to correct these operative problems. Results from this study demonstrate excellent technical success with the AEG in the post-market era. Interventions to resolve implantation complications, when utilized, are highly successful in facilitating AEG implantation and providing technical success.

  8. A Model of Post-Traumatic Epilepsy After Penetrating Brain Injuries: Effect of Lesion Size and Metal Fragments

    PubMed Central

    Kendirli, M. Tansel; Rose, Dominique T.; Bertram, Edward H.

    2014-01-01

    Objective Penetrating brain injury (PBI) has the highest risk for inducing post-traumatic epilepsy and retained foreign materials such as bullet fragments carry the greatest risk. This study examines the potential contribution of copper, a major component of bullets, to the development of epilepsy following PBI. Methods Anesthetized adult male rats received a penetrating injury from the dorsal cortex to the ventral hippocampus from a high speed small bit drill. In one group of animals, copper wire was inserted into the lesion. Control animals had only the lesion or the lesion plus stainless steel wire (biologically inert foreign body). From 6 to up to 11 months following the injury the rats were monitored intermittently for the development of epilepsy with video-EEG. A separate set of animals was examined for possible acute seizures in the week following the injury. Results 22 of the 23 animals with copper wire developed chronic epilepsy compared to 3 of the 20 control rats (lesion and lesion with stainless steel). Copper was associated with more extensive injury. The control rats with epilepsy had larger lesions. In the acute injury group, there was no difference in the incidence of seizures (83% lesion plus stainless steel, 70% lesion plus copper). Conclusions Copper increases the risk for epilepsy and may increase damage over time, but there were no differences between the groups in the incidence of acute post-injury seizures. Lesion size may contribute to epilepsy development in lesion only animals. Copper maybe an independent risk factor for the development of epilepsy and possible secondary injury, but lesion size also contributes to the development of epilepsy. The consequences of prolonged exposure of the brain to copper observed in these animals may have clinical implications that require further evaluation. PMID:25470332

  9. Evaluation of an automatic MR-based gold fiducial marker localisation method for MR-only prostate radiotherapy

    NASA Astrophysics Data System (ADS)

    Maspero, Matteo; van den Berg, Cornelis A. T.; Zijlstra, Frank; Sikkes, Gonda G.; de Boer, Hans C. J.; Meijer, Gert J.; Kerkmeijer, Linda G. W.; Viergever, Max A.; Lagendijk, Jan J. W.; Seevinck, Peter R.

    2017-10-01

    An MR-only radiotherapy planning (RTP) workflow would reduce the cost, radiation exposure and uncertainties introduced by CT-MRI registrations. In the case of prostate treatment, one of the remaining challenges currently holding back the implementation of an RTP workflow is the MR-based localisation of intraprostatic gold fiducial markers (FMs), which is crucial for accurate patient positioning. Currently, MR-based FM localisation is clinically performed manually. This is sub-optimal, as manual interaction increases the workload. Attempts to perform automatic FM detection often rely on being able to detect signal voids induced by the FMs in magnitude images. However, signal voids may not always be sufficiently specific, hampering accurate and robust automatic FM localisation. Here, we present an approach that aims at automatic MR-based FM localisation. This method is based on template matching using a library of simulated complex-valued templates, and exploiting the behaviour of the complex MR signal in the vicinity of the FM. Clinical evaluation was performed on seventeen prostate cancer patients undergoing external beam radiotherapy treatment. Automatic MR-based FM localisation was compared to manual MR-based and semi-automatic CT-based localisation (the current gold standard) in terms of detection rate and the spatial accuracy and precision of localisation. The proposed method correctly detected all three FMs in 15/17 patients. The spatial accuracy (mean) and precision (STD) were 0.9 mm and 0.5 mm respectively, which is below the voxel size of 1.1 × 1.1 × 1.2 mm3 and comparable to MR-based manual localisation. FM localisation failed (3/51 FMs) in the presence of bleeding or calcifications in the direct vicinity of the FM. The method was found to be spatially accurate and precise, which is essential for clinical use. To overcome any missed detection, we envision the use of the proposed method along with verification by an observer. This will result in a semi-automatic workflow facilitating the introduction of an MR-only workflow.

  10. Fibroblast growth factor 20 is protective towards dopaminergic neurons in vivo in a paracrine manner.

    PubMed

    Boshoff, Eugene L; Fletcher, Edward J R; Duty, Susan

    2018-04-23

    Neuroprotective strategies are an unmet medical need for Parkinson's disease. Fibroblast growth factor 20 (FGF20) enhances survival of cultured dopaminergic neurons but little is known about its in vivo potential. We set out to examine whether manipulation of the FGF20 system affected nigrostriatal tract integrity in rats, to identify which fibroblast growth factor receptors (FGFRs) might reside on dopaminergic neurons and to discover the source of endogenous FGF20 in the substantia nigra (SN). Male Sprague Dawley rats were subject to a partial 6-OHDA lesion alongside treatment with exogenous FGF20 or an FGFR antagonist. Behavioural readouts and tyrosine-hydroxylase (TH) immunohistochemistry were used to evaluate nigrostriatal tract integrity. Fluorescent immunohistochemistry was used to examine FGFR subtype expression on TH-positive dopamine neurons and FGF20 cellular localisation within the SN. FGF20 (2.5 μg/day) significantly protected TH-positive cells in the SN and terminals in the striatum, while reducing the development of motor asymmetry at 5, 8 and 11 days post lesion. Conversely, the FGFR antagonist PD173074 (2 mg/kg) significantly worsened both the 6-OHDA lesion and resultant motor asymmetry. Within the SN, TH-positive cells expressed FGFR1, 3 and 4 while FGF20 co-localised with GFAP-positive astrocytes. In conclusion, FGF20 protects dopaminergic neurons in vivo, an action likely mediated through activation of FGFRs1, 3 or 4 found on these neurons. Given FGF20 is localised to astrocytes in the adult SN, endogenous FGF20 provides its protection of dopamine neurons through a paracrine action. Boosting the endogenous FGF20 production might offer potential as a future therapeutic strategy in Parkinson's disease. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  11. Correlation of pretreatment clinical parameters and PSA nadir after high-intensity focused ultrasound (HIFU) for localised prostate cancer.

    PubMed

    Ganzer, Roman; Bründl, Johannes; Koch, Daniel; Wieland, Wolf F; Burger, Maximilian; Blana, Andreas

    2015-01-01

    To determine which pretreatment clinical parameters were predictive of a low prostate-specific antigen (PSA) nadir following high-intensity focused ultrasound (HIFU) treatment. Retrospective study of patients with clinically localised prostate cancer undergoing HIFU at a single centre between December 1997 and September 2009. Whole-gland treatment was applied. Patients also included if they had previously undergone transurethral resection of the prostate (TURP). TURP was also conducted simultaneously to HIFU. Biochemical failure based on Phoenix definition (PSA nadir + 2). Univariate and multivariate analysis of pretreatment clinical parameters conducted to assess those factors predictive of a PSA nadir ≤0.2 and >0.2 ng/ml. Mean (SD) follow-up was 6.2 (2.8) years; median (range) was 6.3 (1.1-12.2) years. Kaplan-Meier estimate of biochemical disease-free survival rate at 8 years was 83 and 48 % for patients achieving a PSA nadir of ≤0.2 and >0.2 ng/ml, respectively. Prostate volume and incidental finding of cancer were significant predictors of low PSA nadir (≤0.2 ng/ml). Prostate volume and incidental finding of cancer could be predictors for oncologic success of HIFU based on post-treatment PSA nadir.

  12. Effects of neutron irradiation on carbon doped MgB2 wire segments

    NASA Astrophysics Data System (ADS)

    Wilke, R. H. T.; Bud'ko, S. L.; Canfield, P. C.; Finnemore, D. K.; Suplinskas, Raymond J.; Farmer, J.; Hannahs, S. T.

    2006-06-01

    We have studied the evolution of superconducting and normal state properties of neutron irradiated Mg(B0.962C0.038)2 wire segments as a function of post-exposure annealing time and temperature. The initial fluence fully suppressed superconductivity and resulted in an anisotropic expansion of the unit cell. Superconductivity was restored by post-exposure annealing. The upper critical field, Hc2(T = 0), approximately scales with Tc, starting with an undamaged Tc near 37 K and Hc2(T = 0) near 32 T. Up to an annealing temperature of 400 °C the recovery of Tc tends to coincide with a decrease in the normal state resistivity and a systematic recovery of the lattice parameters. Above 400 °C a decrease in ordering along the c-direction coincides with an increase in resistivity, but no apparent change in the evolution of Tc and Hc2. To a first order approximation, it appears that carbon doping and neutron damage affect the superconducting properties of MgB2 independently.

  13. Acute Inactivation of Primary Auditory Cortex Causes a Sound Localisation Deficit in Ferrets

    PubMed Central

    Wood, Katherine C.; Town, Stephen M.; Atilgan, Huriye; Jones, Gareth P.

    2017-01-01

    The objective of this study was to demonstrate the efficacy of acute inactivation of brain areas by cooling in the behaving ferret and to demonstrate that cooling auditory cortex produced a localisation deficit that was specific to auditory stimuli. The effect of cooling on neural activity was measured in anesthetized ferret cortex. The behavioural effect of cooling was determined in a benchmark sound localisation task in which inactivation of primary auditory cortex (A1) is known to impair performance. Cooling strongly suppressed the spontaneous and stimulus-evoked firing rates of cortical neurons when the cooling loop was held at temperatures below 10°C, and this suppression was reversed when the cortical temperature recovered. Cooling of ferret auditory cortex during behavioural testing impaired sound localisation performance, with unilateral cooling producing selective deficits in the hemifield contralateral to cooling, and bilateral cooling producing deficits on both sides of space. The deficit in sound localisation induced by inactivation of A1 was not caused by motivational or locomotor changes since inactivation of A1 did not affect localisation of visual stimuli in the same context. PMID:28099489

  14. Probabilistic self-localisation on a qualitative map based on occlusions

    NASA Astrophysics Data System (ADS)

    Santos, Paulo E.; Martins, Murilo F.; Fenelon, Valquiria; Cozman, Fabio G.; Dee, Hannah M.

    2016-09-01

    Spatial knowledge plays an essential role in human reasoning, permitting tasks such as locating objects in the world (including oneself), reasoning about everyday actions and describing perceptual information. This is also the case in the field of mobile robotics, where one of the most basic (and essential) tasks is the autonomous determination of the pose of a robot with respect to a map, given its perception of the environment. This is the problem of robot self-localisation (or simply the localisation problem). This paper presents a probabilistic algorithm for robot self-localisation that is based on a topological map constructed from the observation of spatial occlusion. Distinct locations on the map are defined by means of a classical formalism for qualitative spatial reasoning, whose base definitions are closer to the human categorisation of space than traditional, numerical, localisation procedures. The approach herein proposed was systematically evaluated through experiments using a mobile robot equipped with a RGB-D sensor. The results obtained show that the localisation algorithm is successful in locating the robot in qualitatively distinct regions.

  15. A new range-free localisation in wireless sensor networks using support vector machine

    NASA Astrophysics Data System (ADS)

    Wang, Zengfeng; Zhang, Hao; Lu, Tingting; Sun, Yujuan; Liu, Xing

    2018-02-01

    Location information of sensor nodes is of vital importance for most applications in wireless sensor networks (WSNs). This paper proposes a new range-free localisation algorithm using support vector machine (SVM) and polar coordinate system (PCS), LSVM-PCS. In LSVM-PCS, two sets of classes are first constructed based on sensor nodes' polar coordinates. Using the boundaries of the defined classes, the operation region of WSN field is partitioned into a finite number of polar grids. Each sensor node can be localised into one of the polar grids by executing two localisation algorithms that are developed on the basis of SVM classification. The centre of the resident polar grid is then estimated as the location of the sensor node. In addition, a two-hop mass-spring optimisation (THMSO) is also proposed to further improve the localisation accuracy of LSVM-PCS. In THMSO, both neighbourhood information and non-neighbourhood information are used to refine the sensor node location. The results obtained verify that the proposed algorithm provides a significant improvement over existing localisation methods.

  16. Strain localisation in mechanically layered rocks beneath detachment zones: insights from numerical modelling

    NASA Astrophysics Data System (ADS)

    Le Pourhiet, L.; Huet, B.; Labrousse, L.; Yao, K.; Agard, P.; Jolivet, L.

    2013-04-01

    We have designed a series of fully dynamic numerical simulations aimed at assessing how the orientation of mechanical layering in rocks controls the orientation of shear bands and the depth of penetration of strain in the footwall of detachment zones. Two parametric studies are presented. In the first one, the influence of stratification orientation on the occurrence and mode of strain localisation is tested by varying initial dip of inherited layering in the footwall with regard to the orientation of simple shear applied at the rigid boundary simulating a rigid hanging wall, all scaling and rheological parameter kept constant. It appears that when Mohr-Coulomb plasticity is being used, shear bands are found to localise only when the layering is being stretched. This corresponds to early deformational stages for inital layering dipping in the same direction as the shear is applied, and to later stages for intial layering dipping towards the opposite direction of shear. In all the cases, localisation of the strain after only γ=1 requires plastic yielding to be activated in the strong layer. The second parametric study shows that results are length-scale independent and that orientation of shear bands is not sensitive to the viscosity contrast or the strain rate. However, decreasing or increasing strain rate is shown to reduce the capacity of the shear zone to localise strain. In the later case, the strain pattern resembles a mylonitic band but the rheology is shown to be effectively linear. Based on the results, a conceptual model for strain localisation under detachment faults is presented. In the early stages, strain localisation occurs at slow rates by viscous shear instabilities but as the layered media is exhumed, the temperature drops and the strong layers start yielding plastically, forming shear bands and localising strain at the top of the shear zone. Once strain localisation has occured, the deformation in the shear band becomes extremely penetrative but the strength cannot drop since the shear zone has a finite thickness.

  17. Nuclear localisation of 53BP1 is regulated by phosphorylation of the nuclear localisation signal.

    PubMed

    von Morgen, Patrick; Lidak, Tomas; Horejsi, Zuzana; Macurek, Libor

    2018-06-01

    Repair of damaged DNA is essential for maintaining genomic stability. TP53-binding protein 1 (53BP1) plays an important role in repair of the DNA double-strand breaks. Nuclear localisation of 53BP1 depends on importin β and nucleoporin 153, but the type and location of 53BP1 nuclear localisation signal (NLS) have yet to be determined. Here, we show that nuclear import of 53BP1 depends on two basic regions, namely 1667-KRK-1669 and 1681-KRGRK-1685, which are both needed for importin binding. Lysine 1667 is essential for interaction with importin and its substitution to arginine reduced nuclear localisation of 53BP1. Furthermore, we have found that CDK1-dependent phosphorylation of 53BP1 at S1678 impairs importin binding during mitosis. Phosphorylation-mimicking mutant S1678D showed reduced nuclear localisation, suggesting that phosphorylation of the NLS interferes with nuclear import of the 53BP1 CONCLUSIONS: We show that 53BP1 contains a classical bipartite NLS 1666-GKRKLITSEEERSPAKRGRKS-1686, which enables the importin-mediated nuclear transport of 53BP1. Additionally, we found that posttranslational modification within the NLS region can regulate 53BP1 nuclear import. Our results indicate that integrity of the NLS is important for 53BP1 nuclear localisation. Precise mapping of the NLS will facilitate further studies on the effect of posttranslational modifications and somatic mutations on the nuclear localisation 53BP1 and DNA repair. © 2018 Société Française des Microscopies and Société de Biologie Cellulaire de France. Published by John Wiley & Sons Ltd.

  18. Is the Pauli exclusion principle the origin of electron localisation?

    NASA Astrophysics Data System (ADS)

    Rincón, Luis; Torres, F. Javier; Almeida, Rafael

    2018-03-01

    In this work, we inquire into the origins of the electron localisation as obtained from the information content of the same-spin pair density, γσ, σ(r2∣r1). To this end, we consider systems of non-interacting and interacting identical Fermions contained in two simple 1D potential models: (1) an infinite potential well and (2) the Kronig-Penney periodic potential. The interparticle interaction is considered through the Hartree-Fock approximation as well as the configuration interaction expansion. Morover, the electron localisation is described through the Kullback-Leibler divergence between γσ, σ(r2∣r1) and its associated marginal probability. The results show that, as long as the adopted method properly includes the Pauli principle, the electronic localisation depends only modestly on the interparticle interaction. In view of the latter, one may conclude that the Pauli principle is the main responsible for the electron localisation.

  19. Tumour Suppressor Adenomatous Polyposis Coli (APC) localisation is regulated by both Kinesin-1 and Kinesin-2.

    PubMed

    Ruane, Peter T; Gumy, Laura F; Bola, Becky; Anderson, Beverley; Wozniak, Marcin J; Hoogenraad, Casper C; Allan, Victoria J

    2016-06-07

    Microtubules and their associated proteins (MAPs) underpin the polarity of specialised cells. Adenomatous polyposis coli (APC) is one such MAP with a multifunctional agenda that requires precise intracellular localisations. Although APC has been found to associate with kinesin-2 subfamily members, the exact mechanism for the peripheral localization of APC remains unclear. Here we show that the heavy chain of kinesin-1 directly interacts with the APC C-terminus, contributing to the peripheral localisation of APC in fibroblasts. In rat hippocampal neurons the kinesin-1 binding domain of APC is required for its axon tip enrichment. Moreover, we demonstrate that APC requires interactions with both kinesin-2 and kinesin-1 for this localisation. Underlining the importance of the kinesin-1 association, neurons expressing APC lacking kinesin-1-binding domain have shorter axons. The identification of this novel kinesin-1-APC interaction highlights the complexity and significance of APC localisation in neurons.

  20. Comparison of the outcome following the fixation of osteotomies or fractures associated with total hip replacement using cables or wires: the results at five years.

    PubMed

    Berton, C; Puskas, G J; Christofilopoulos, P; Stern, R; Hoffmeyer, P; Lübbeke, A

    2012-11-01

    There are no recent studies comparing cable with wire for the fixation of osteotomies or fractures in total hip replacement (THR). Our objective was to evaluate the five-year clinical and radiological outcomes and complication rates of the two techniques. We undertook a review including all primary and revision THRs performed in one hospital between 1996 and 2005 using cable or wire fixation. Clinical and radiological evaluation was performed five years post-operatively. Cables were used in 51 THRs and wires in 126, and of these, 36 THRs with cable (71%) and 101 with wire (80%) were evaluated at follow-up. The five-year radiographs available for 33 cable and 91 wire THRs revealed rates of breakage of fixation of 12 of 33 (36%) and 42 of 91 (46%), respectively. With cable there was a significantly higher risk of metal debris (68% vs. 9%; adjusted relative risk (RR) 6.6; 95% confidence interval (CI) 3.0 to 14.1), nonunion (36% vs. 21%; adjusted RR 2.0; 95% CI 1.0 to 3.9) and osteolysis around the material, acetabulum or femur (61% vs 19%; adjusted RR 3.9; 95% CI 2.3 to 6.5). Cable breakage increased the risk of osteolysis to 83%. There was a trend towards foreign-body reaction and increased infection with cables. Clinical results did not differ between the groups. In conclusion, we found a higher incidence of complications and a trend towards increased infection and foreign-body reaction with the use of cables.

  1. Differential co-localisation of the P2X7 receptor subunit with vesicular glutamate transporters VGLUT1 and VGLUT2 in rat CNS.

    PubMed

    Atkinson, L; Batten, T F C; Moores, T S; Varoqui, H; Erickson, J D; Deuchars, J

    2004-01-01

    Presynaptic P2X(7) receptors are thought to play a role in the modulation of transmitter release and have been localised to terminals with the location and morphology typical of excitatory boutons. To test the hypothesis that this receptor is preferentially associated with excitatory terminals we combined immunohistochemistry for the P2X(7) receptor subunit (P2X(7)R) with that for two vesicular glutamate transporters (VGLUT1 and VGLUT2) in the rat CNS. This confirmed that P2X(7)R immunoreactivity (IR) is present in glutamatergic terminals; however, whether it was co-localised with VGLUT1-IR or VGLUT2-IR depended on the CNS region examined. In the spinal cord, P2X(7)R-IR co-localised with VGLUT2-IR. In the brainstem, co-localisation of P2X(7)R-IR with VGLUT2-IR was widespread, but co-localisation with VGLUT1-IR was seen only in the external cuneate nucleus and spinocerebellar tract region of the ventral medulla. In the cerebellum, P2X(7)R-IR co-localised with both VGLUT1 and VGLUT2-IR in the granular layer. In the hippocampus it was co-localised only with VGLUT1-IR, including in the polymorphic layer of the dentate gyrus and the substantia radiatum of the CA3 region. In other forebrain areas, P2X(7)R-IR co-localised with VGLUT1-IR throughout the amygdala, caudate putamen, striatum, reticular thalamic nucleus and cortex and with VGLUT2-IR in the dorsal lateral geniculate nucleus, amygdala and hypothalamus. Dual labelling studies performed using markers for cholinergic, monoaminergic, GABAergic and glycinergic terminals indicated that in certain brainstem and spinal cord nuclei the P2X(7)R is also expressed by subpopulations of cholinergic and GABAergic/glycinergic terminals. These data support our previous hypothesis that the P2X(7)R may play a role in modulating glutamate release in functionally different systems throughout the CNS but further suggest a role in modulating release of inhibitory transmitters in some regions.

  2. Forensic investigation into a death: post-traumatic amnesia in a worker with a work-related head injury sustained in a coal-fired thermal power plant in India.

    PubMed

    Muralidhar, Venkiteswaran

    2017-03-15

    This is the first reported case of a work-related head injury in a coal-fired thermal power plant in India. This case highlights the trend of not reporting work injuries due to fears of reprisal from the management team that may include the termination of employment. Post-traumatic amnesia in a worker presenting with head trauma must be recognised by coworkers, so the cause of injury can be elicited early and the victim gets timely medical help. There are few published studies on work-related traumatic brain injury, and they provide no information on either anatomical localisation or signs and symptoms. It is imperative that this under-researched area is studied, so detailed epidemiology and accurate national and global statistics are made available to address this dangerous yet preventable condition. 2017 BMJ Publishing Group Ltd.

  3. Neuronal NOS localises to human airway cilia.

    PubMed

    Jackson, Claire L; Lucas, Jane S; Walker, Woolf T; Owen, Holly; Premadeva, Irnthu; Lackie, Peter M

    2015-01-30

    Airway NO synthase (NOS) isoenzymes are responsible for rapid and localised nitric oxide (NO) production and are expressed in airway epithelium. We sought to determine the localisation of neuronal NOS (nNOS) in airway epithelium due to the paucity of evidence. Sections of healthy human bronchial tissue in glycol methacrylate resin and human nasal polyps in paraffin wax were immunohistochemically labelled and reproducibly demonstrated nNOS immunoreactivity, particularly at the proximal portion of cilia; this immunoreactivity was blocked by a specific nNOS peptide fragment. Healthy human epithelial cells differentiated at an air-liquid interface (ALI) confirmed the presence of all three NOS isoenzymes by immunofluorescence labelling. Only nNOS immunoreactivity was specific to the ciliary axonemeand co-localised with the cilia marker β-tubulin in the proximal part of the ciliary axoneme. We report a novel localisation of nNOS at the proximal portion of cilia in airway epithelium and conclude that its independent and local regulation of NO levels is crucial for normal cilia function. Copyright © 2014 Elsevier Inc. All rights reserved.

  4. Tumour Suppressor Adenomatous Polyposis Coli (APC) localisation is regulated by both Kinesin-1 and Kinesin-2

    PubMed Central

    Ruane, Peter T.; Gumy, Laura F.; Bola, Becky; Anderson, Beverley; Wozniak, Marcin J.; Hoogenraad, Casper C.; Allan, Victoria J.

    2016-01-01

    Microtubules and their associated proteins (MAPs) underpin the polarity of specialised cells. Adenomatous polyposis coli (APC) is one such MAP with a multifunctional agenda that requires precise intracellular localisations. Although APC has been found to associate with kinesin-2 subfamily members, the exact mechanism for the peripheral localization of APC remains unclear. Here we show that the heavy chain of kinesin-1 directly interacts with the APC C-terminus, contributing to the peripheral localisation of APC in fibroblasts. In rat hippocampal neurons the kinesin-1 binding domain of APC is required for its axon tip enrichment. Moreover, we demonstrate that APC requires interactions with both kinesin-2 and kinesin-1 for this localisation. Underlining the importance of the kinesin-1 association, neurons expressing APC lacking kinesin-1-binding domain have shorter axons. The identification of this novel kinesin-1-APC interaction highlights the complexity and significance of APC localisation in neurons. PMID:27272132

  5. Acoustic emission source localization based on distance domain signal representation

    NASA Astrophysics Data System (ADS)

    Gawronski, M.; Grabowski, K.; Russek, P.; Staszewski, W. J.; Uhl, T.; Packo, P.

    2016-04-01

    Acoustic emission is a vital non-destructive testing technique and is widely used in industry for damage detection, localisation and characterization. The latter two aspects are particularly challenging, as AE data are typically noisy. What is more, elastic waves generated by an AE event, propagate through a structural path and are significantly distorted. This effect is particularly prominent for thin elastic plates. In these media the dispersion phenomenon results in severe localisation and characterization issues. Traditional Time Difference of Arrival methods for localisation techniques typically fail when signals are highly dispersive. Hence, algorithms capable of dispersion compensation are sought. This paper presents a method based on the Time - Distance Domain Transform for an accurate AE event localisation. The source localisation is found through a minimization problem. The proposed technique focuses on transforming the time signal to the distance domain response, which would be recorded at the source. Only, basic elastic material properties and plate thickness are used in the approach, avoiding arbitrary parameters tuning.

  6. [Localised bronchi amyloidosis: a case report].

    PubMed

    Ayadi, Lobna; Khabir, Abdelmajid; Boudawara, Tahya; Makni, Saloua; Rekik, Wajdi Karim; Ayoub, Abdelkader; Jlidi, Rachid

    2004-02-01

    Localised pulmonary amyloïdosis is exceptional. Tracheobronchial symptoms are the most frequent. We report a case of a 68 year-old man complaining of cough and breathlessness. Bronchoscopy showed a submucosal infiltration with stenosis of left upper and lower bronchi. Multiples biopsy were performed and concluded to amyloïdosis of AL type. Our objective is to describe the anatomopathologic aspects of localised pulmonary amyloïdosis and to discuss its pathogeny.

  7. Sensory Perception in the Human Research and Engineering Directorate: Thrust Areas and Recent Research 2011-2014

    DTIC Science & Technology

    2014-09-01

    estimation in an open space. In: Glotin, editor. Soundscape semiotics: localisation and categorisation. Rijeka (Croatia): InTech; 2014. Available at...Glotin H, editor. Soundscape semiotics – localisation and categorisation. Rijeka (Croatia): InTech; 2014. Available at: http://www.intechopen.com...books/ soundscape -semiotics-localisation -and-categorisation/auditory-distance-estimation-in-an-open-space. The purpose of the study was to expand our

  8. Fukunaga-Koontz feature transformation for statistical structural damage detection and hierarchical neuro-fuzzy damage localisation

    NASA Astrophysics Data System (ADS)

    Hoell, Simon; Omenzetter, Piotr

    2017-07-01

    Considering jointly damage sensitive features (DSFs) of signals recorded by multiple sensors, applying advanced transformations to these DSFs and assessing systematically their contribution to damage detectability and localisation can significantly enhance the performance of structural health monitoring systems. This philosophy is explored here for partial autocorrelation coefficients (PACCs) of acceleration responses. They are interrogated with the help of the linear discriminant analysis based on the Fukunaga-Koontz transformation using datasets of the healthy and selected reference damage states. Then, a simple but efficient fast forward selection procedure is applied to rank the DSF components with respect to statistical distance measures specialised for either damage detection or localisation. For the damage detection task, the optimal feature subsets are identified based on the statistical hypothesis testing. For damage localisation, a hierarchical neuro-fuzzy tool is developed that uses the DSF ranking to establish its own optimal architecture. The proposed approaches are evaluated experimentally on data from non-destructively simulated damage in a laboratory scale wind turbine blade. The results support our claim of being able to enhance damage detectability and localisation performance by transforming and optimally selecting DSFs. It is demonstrated that the optimally selected PACCs from multiple sensors or their Fukunaga-Koontz transformed versions can not only improve the detectability of damage via statistical hypothesis testing but also increase the accuracy of damage localisation when used as inputs into a hierarchical neuro-fuzzy network. Furthermore, the computational effort of employing these advanced soft computing models for damage localisation can be significantly reduced by using transformed DSFs.

  9. Copper, Aluminum and Nickel: A New Monocrystalline Orthodontic Alloy

    NASA Astrophysics Data System (ADS)

    Wierenga, Mark

    Introduction: This study was designed to evaluate, via tensile and bend testing, the mechanical properties of a newly-developed monocrystalline orthodontic archwire comprised of a blend of copper, aluminum, and nickel (CuAlNi). Methods: The sample was comprised of three shape memory alloys; CuAlNi, copper nickel titanium (CuNiTi), and nickel titanium (NiTi); from various orthodontic manufacturers in both 0.018" round and 0.019" x 0.025" rectangular dimensions. Additional data was gathered for similarly sized stainless steel and beta-titanium archwires as a point of reference for drawing conclusions about the relative properties of the archwires. Measurements of loading and unloading forces were recorded in both tension and deflection testing. Repeated-measure ANOVA (alpha= 0.05) was used to compare loading and unloading forces across wires and one-way ANOVA (alpha= 0.05) was used to compare elastic moduli and hysteresis. To identify significant differences, Tukey post-hoc comparisons were performed. Results: The modulus of elasticity, deflection forces, and hysteresis profiles of CuAlNi were significantly different than the other superelastic wires tested. In all tests, CuAlNi had a statistically significant lower modulus of elasticity compared to the CuNiTi and NiTi wires (P <0.0001). The CuAlNi wire exhibited significantly lower loading and unloading forces than any other wire tested. In round wire tensile tests, loading force at all deflections was significantly lower for CuAlNi than CuNiTi or NiTi (P <0.0001). In tensile testing, the CuAlNi alloy was able to recover from a 7 mm extension (10% elongation) without permanent deformation and with little to no loss in force output. In large-deflection bend tests at 4, 5, and 6 mm deflection, CuAlNi showed the significantly lowest loading forces across the three wire materials (P <0.0001). The NiTi wires showed up to 12 times the amount of energy loss due to hysteresis compared to CuAlNi. CuAlNi showed a hysteresis loss that was significantly less than any other wire tested in this study (P <0.0001). Conclusions: The relatively constant force delivered for a long period of time during the deactivation of this wire, the minimal hysteresis loss, the low force output in deflection, and the relatively low modulus of elasticity suggest that CuAlNi wires should be considered an important material addition to orthodontic metallurgy.

  10. bicoid RNA localization requires specific binding of an endosomal sorting complex

    PubMed Central

    Irion, Uwe; St Johnston, Daniel

    2007-01-01

    Summary paragraph: bicoid mRNA localises to the anterior of the Drosophila egg, where it is translated to form a morphogen gradient of Bicoid protein that patterns the head and thorax of the embryo. Although bicoid was the first identified localised cytoplasmic determinant1-4, little is known about how the mRNA is coupled to the microtubule-dependent transport pathway that targets it to the anterior, and it has been proposed that it is recognised by a complex of many redundant proteins, each of which binds to the localisation element in its 3'UTR with little or no specificity5. Indeed, the only known RNA-binding protein that co-localises with bicoid mRNA is Staufen, which binds non-specifically to dsRNA in vitro6, 7. Here we show that mutants in all subunits of the ESCRT-II complex (Vps22, Vps25 and Vps36) abolish the final Staufen-dependent step in bcd RNA localisation. ESCRT-II is a highly conserved component of the pathway that sorts ubiquitinated endosomal proteins into internal vesicles8, 9, and functions as a tumour-suppressor by removing activated receptors from the cytoplasm10, 11. However, the role of ESCRT-II in bicoid localisation appears to be independent of endosomal sorting, because mutations in ESCRT-I and III components have no effect of the targeting of bicoid mRNA. Instead, Vps36 functions by binding directly and specifically to stem-loop V of the bicoid 3'UTR through its N-terminal GLUE domain12, making it the first example of a sequence specific RNA-binding protein that recognises the bicoid localisation signal. Furthermore, Vps36 localises to the anterior of the oocyte in a bicoid mRNA-dependent manner, and is required for the subsequent recruitment of Staufen to the bicoid complex. This novel function of ESCRT-II as an RNA-binding complex is conserved in vertebrates, and may explain some of its roles that are independent of endosomal sorting. PMID:17268469

  11. [Treatment of clavicular fractures using intramedullary nailing or K-wire versus plating fixation: a meta-analysis].

    PubMed

    Zhang, Ke-xue; Zhao, Jing-xin; Zhao, Zhe; Ng, Li-cheng; Su, Xiu-yun; Long, An-hua; Mao, Zhi; Zhang, Jin-hui; Zhang, Li-hai; Tang, Pei-fu

    2015-05-01

    TFo compare the efficacy and complications rate of intramedullary (IM) nailing or K-wire versus plating fixation for clavicular fractures. Pubmed, Embase, Cochrane Library databases, CNKI, VIP and Wangfang databases were searched to find all randomized or quasi-randomized controlled trials of clavicle fractures using plating versus IM nailing or K-wire. The methodologic quality of the studies was assessed. After independent study selection by 2 authors ,data were collected and extracted independently. Outcomes of postoperative shoulder functional measurement, the efficacy and information of the operation and complications rate were meta-analyzed using RevMan 5 software. Nine hundreds and seventy-six patients in 10 randomized controlled trials (RCTs) and 3 quasi-RCTs were involved in the meta-analysis,of which 5 studies compared the K-wire and the plating fixations and 8 studies compared the IM nailing and the plating fixations. The overall odds ratio(OR) (with 95% CI) of the operation efficacy for K-wire versus the plating was 3.79 (1.93, 7.46). The overall weighted mean difference (with 95% CI) of Constant Shoulder score for plating versus IM fixation was -1.39 (-3.43, 0.65) in 6 studies. The overall OR of the plating versus IM nailing was 9.34(2.70, 32.32) for the overall major complications in 5 studies and 5.04 (1.52,16.77) for the revision rate in 5 studies. The current limited evidences suggested that the IM fixation could reduce the incidences of the overall major complications and the revision surgery, while the post-operative efficacy of the plating was superior to the K-wire. More high quality RCTs are still needed in the future.

  12. Membrane-association of mRNA decapping factors is independent of stress in budding yeast

    PubMed Central

    Huch, Susanne; Gommlich, Jessie; Muppavarapu, Mridula; Beckham, Carla; Nissan, Tracy

    2016-01-01

    Recent evidence has suggested that the degradation of mRNA occurs on translating ribosomes or alternatively within RNA granules called P bodies, which are aggregates whose core constituents are mRNA decay proteins and RNA. In this study, we examined the mRNA decapping proteins, Dcp1, Dcp2, and Dhh1, using subcellular fractionation. We found that decapping factors co-sediment in the polysome fraction of a sucrose gradient and do not alter their behaviour with stress, inhibition of translation or inhibition of the P body formation. Importantly, their localisation to the polysome fraction is independent of the RNA, suggesting that these factors may be constitutively localised to the polysome. Conversely, polysomal and post-polysomal sedimentation of the decapping proteins was abolished with the addition of a detergent, which shifts the factors to the non-translating RNP fraction and is consistent with membrane association. Using a membrane flotation assay, we observed the mRNA decapping factors in the lower density fractions at the buoyant density of membrane-associated proteins. These observations provide further evidence that mRNA decapping factors interact with subcellular membranes, and we suggest a model in which the mRNA decapping factors interact with membranes to facilitate regulation of mRNA degradation. PMID:27146487

  13. Membrane-association of mRNA decapping factors is independent of stress in budding yeast.

    PubMed

    Huch, Susanne; Gommlich, Jessie; Muppavarapu, Mridula; Beckham, Carla; Nissan, Tracy

    2016-05-05

    Recent evidence has suggested that the degradation of mRNA occurs on translating ribosomes or alternatively within RNA granules called P bodies, which are aggregates whose core constituents are mRNA decay proteins and RNA. In this study, we examined the mRNA decapping proteins, Dcp1, Dcp2, and Dhh1, using subcellular fractionation. We found that decapping factors co-sediment in the polysome fraction of a sucrose gradient and do not alter their behaviour with stress, inhibition of translation or inhibition of the P body formation. Importantly, their localisation to the polysome fraction is independent of the RNA, suggesting that these factors may be constitutively localised to the polysome. Conversely, polysomal and post-polysomal sedimentation of the decapping proteins was abolished with the addition of a detergent, which shifts the factors to the non-translating RNP fraction and is consistent with membrane association. Using a membrane flotation assay, we observed the mRNA decapping factors in the lower density fractions at the buoyant density of membrane-associated proteins. These observations provide further evidence that mRNA decapping factors interact with subcellular membranes, and we suggest a model in which the mRNA decapping factors interact with membranes to facilitate regulation of mRNA degradation.

  14. Surface characterization of nickel titanium orthodontic arch wires

    PubMed Central

    Krishnan, Manu; Seema, Saraswathy; Tiwari, Brijesh; Sharma, Himanshu S.; Londhe, Sanjay; Arora, Vimal

    2015-01-01

    Background Surface roughness of nickel titanium orthodontic arch wires poses several clinical challenges. Surface modification with aesthetic/metallic/non metallic materials is therefore a recent innovation, with clinical efficacy yet to be comprehensively evaluated. Methods One conventional and five types of surface modified nickel titanium arch wires were surface characterized with scanning electron microscopy, energy dispersive analysis, Raman spectroscopy, Atomic force microscopy and 3D profilometry. Root mean square roughness values were analyzed by one way analysis of variance and post hoc Duncan's multiple range tests. Results Study groups demonstrated considerable reduction in roughness values from conventional in a material specific pattern: Group I; conventional (578.56 nm) > Group V; Teflon (365.33 nm) > Group III; nitride (301.51 nm) > Group VI (i); rhodium (290.64 nm) > Group VI (ii); silver (252.22 nm) > Group IV; titanium (229.51 nm) > Group II; resin (158.60 nm). It also showed the defects with aesthetic (resin/Teflon) and nitride surfaces and smooth topography achieved with metals; titanium/silver/rhodium. Conclusions Resin, Teflon, titanium, silver, rhodium and nitrides were effective in decreasing surface roughness of nickel titanium arch wires albeit; certain flaws. Findings have clinical implications, considering their potential in lessening biofilm adhesion, reducing friction, improving corrosion resistance and preventing nickel leach and allergic reactions. PMID:26843749

  15. Use of epicardial pacing wires after coronary artery bypass surgery.

    PubMed

    Sorensen, E R; Manna, D; McCourt, K

    1994-01-01

    To replicate a previous study that described the incidence and characteristics of patients after coronary artery bypass graft surgery who required the use of epicardial pacing wires and to explore the reasons for epicardial pacing wire use in this patient population. Ex post facto descriptive correlational. Cardiothoracic intensive care and step down units of a 500-bed medical center. Convenience sample of 196 patients after coronary artery bypass graft surgery, 165 who did not use the epicardial pacing wires and 31 who used the epicardial pacing wires to augment cardiac output, diagnose dysrhythmias, suppress dysrhythmias, or treat heart block. Patients receiving other surgical techniques in combination with coronary artery bypass graft surgery were not included. Recording of demographic and clinical data for all of the sample population, with additional data collected when the epicardial pacing wires were used. Independent t test and chi-square analysis were used to determine significance between the means and frequencies in the variables of the patients who used the epicardial pacing wires and those who did not. The significance level was set at 0.05. There were no statistically significant differences between the groups in terms of age or previous or recent myocardial infarction, which was opposite of the replicated study's findings. A statistically significant difference (p < 0.001) was found between the groups for the use of inotropic support, which was also opposite of the findings of that study. The group requiring epicardial pacing wire utilization demonstrated a greater need for diuretics in the preoperative phase than those who did not (p < 0.01), as well as a higher use of digitalis therapy before surgery (p < 0.01). Additionally, those who were paced experienced a greater cardiac output (p = 0.013) and cardiac index (p = 0.018) after pacing was initiated. The variation in findings between this study and the one replicated may be the result of variations in the patient populations, treatment practices, or preoperative condition. Replication of this study at a future date may reveal variables not identified here.

  16. Several adaptor proteins promote intracellular localisation of the transporter MRP4/ABCC4 in platelets and haematopoietic cells.

    PubMed

    Schaletzki, Yvonne; Kromrey, Marie-Luise; Bröderdorf, Susanne; Hammer, Elke; Grube, Markus; Hagen, Paul; Sucic, Sonja; Freissmuth, Michael; Völker, Uwe; Greinacher, Andreas; Rauch, Bernhard H; Kroemer, Heyo K; Jedlitschky, Gabriele

    2017-01-05

    The multidrug resistance protein 4 (MRP4/ABCC4) has been identified as an important transporter for signalling molecules including cyclic nucleotides and several lipid mediators in platelets and may thus represent a novel target to interfere with platelet function. Besides its localisation in the plasma membrane, MRP4 has been also detected in the membrane of dense granules in resting platelets. In polarised cells it is localised at the basolateral or apical plasma membrane. To date, the mechanism of MRP4 trafficking has not been elucidated; protein interactions may regulate both the localisation and function of this transporter. We approached this issue by searching for interacting proteins by in vitro binding assays, followed by immunoblotting and mass spectrometry, and by visualising their co-localisation in platelets and haematopoietic cells. We identified the PDZ domain containing scaffold proteins ezrin-binding protein 50 (EBP50/NHERF1), postsynaptic density protein 95 (PSD95), and sorting nexin 27 (SNX27), but also the adaptor protein complex 3 subunit β3A (AP3B1) and the heat shock protein HSP90 as putative interaction partners of MRP4. The knock-down of SNX27, PSD95, and AP3B1 by siRNA in megakaryoblastic leukaemia cells led to a redistribution of MRP4 from intracellular structures to the plasma membrane. Inhibition of HSP90 led to a diminished expression and retention of MRP4 in the endoplasmic reticulum. These results indicate that MRP4 localisation and function are regulated by multiple protein interactions. Changes in the adaptor proteins can hence lead to altered localisation and function of the transporter.

  17. Germ plasm localisation of the HELICc of Vasa in Drosophila: analysis of domain sufficiency and amino acids critical for localisation

    NASA Astrophysics Data System (ADS)

    Wang, Szu-Chieh; Hsu, Hao-Jen; Lin, Gee-Way; Wang, Ting-Fang; Chang, Chun-Che; Lin, Ming-Der

    2015-09-01

    Formation of the germ plasm drives germline specification in Drosophila and some other insects such as aphids. Identification of the DEAD-box protein Vasa (Vas) as a conserved germline marker in flies and aphids suggests that they share common components for assembling the germ plasm. However, to which extent the assembly order is conserved and the correlation between functions and sequences of Vas remain unclear. Ectopic expression of the pea aphid Vas (ApVas1) in Drosophila did not drive its localisation to the germ plasm, but ApVas1 with a replaced C-terminal domain (HELICc) of Drosophila Vas (DmVas) became germ-plasm restricted. We found that HELICc itself, through the interaction with Oskar (Osk), was sufficient for germ-plasm localisation. Similarly, HELICc of the grasshopper Vas could be recruited to the germ plasm in Drosophila. Nonetheless, germ-plasm localisation was not seen in the Drosophila oocytes expressing HELICcs of Vas orthologues from aphids, crickets, and mice. We further identified that glutamine (Gln) 527 within HELICc of DmVas was critical for localisation, and its corresponding residue could also be detected in grasshopper Vas yet missing in the other three species. This suggests that Gln527 is a direct target of Osk or critical to the maintenance of HELICc conformation.

  18. STS-114: Discovery Post MMT Press Conference

    NASA Technical Reports Server (NTRS)

    2005-01-01

    George Diller, NASA Public Affairs, introduces the panel who consist of: Bill Parsons, Space Shuttle Program Manager; Wayne Hale, Space Shuttle Deputy Program Manager; Ed Mango, Deputy Manager JSC Orbiter Project Office; and Mike Wetmore, Director of Shuttle Processing. Bill Parsons begins by expressing that he is still searching for the problem with the low level fuel sensor inside the external tank. Hale talks about more ambient tests that will be performed to fix this problem. Mango expresses his findings from tests in the aft engine compartment, point sensor box, orbiter wiring, and wire resistance. He also talks about looking in detail into the circuit analysis of the point sensor box. Questions from the news media about tanking tests and extending the launch window are addressed.

  19. Control of surface defects on plasma-MIG hybrid welds in cryogenic aluminum alloys

    NASA Astrophysics Data System (ADS)

    Lee, Hee-Keun; Chun, Kwang-San; Park, Sang-Hyeon; Kang, Chung-Yun

    2015-07-01

    Lately, high production rate welding processes for Al alloys, which are used as LNG FPSO cargo containment system material, have been developed to overcome the limit of installation and high rework rates. In particular, plasma-metal inert gas (MIG) hybrid (PMH) welding can be used to obtain a higher deposition rate and lower porosity, while facilitating a cleaning effect by preheating and post heating the wire and the base metal. However, an asymmetric undercut and a black-colored deposit are created on the surface of PMH weld in Al alloys. For controlling the surface defect formation, the wire feeding speed and nozzle diameter in the PMH weld was investigated through arc phenomena with high-speed imaging and metallurgical analysis.

  20. Frame-mounted wire management device

    DOEpatents

    Grushkowitz, Tyler; Fischer, Kevin; Danning, Matthew

    2016-09-20

    A wire management device is disclosed. The device comprises a clip comprising an upper planar member and a lower planar member, each planar member having an inner and outer surface, wherein the inner surface of the upper planar member includes a post extending toward the inner surface of the lower planar member, a stem extending from the outer surface of the lower planar member, the stem including two outwardly-extending flanges, each of the first and second outwardly-extending flanges including an edge portion extending toward the outer surface of the lower planar member, and a transverse passage extending along the outer surface of the lower planar member, the transverse passage extending across the stem, wherein the stem has a recessed portion along the transverse passage.

  1. Assessing the Nature of the Distribution of Localised States in Bulk GaAsBi.

    PubMed

    Wilson, Tom; Hylton, Nicholas P; Harada, Yukihiro; Pearce, Phoebe; Alonso-Álvarez, Diego; Mellor, Alex; Richards, Robert D; David, John P R; Ekins-Daukes, Nicholas J

    2018-04-24

    A comprehensive assessment of the nature of the distribution of sub band-gap energy states in bulk GaAsBi is presented using power and temperature dependent photoluminescence spectroscopy. The observation of a characteristic red-blue-red shift in the peak luminescence energy indicates the presence of short-range alloy disorder in the material. A decrease in the carrier localisation energy demonstrates the strong excitation power dependence of localised state behaviour and is attributed to the filling of energy states furthest from the valence band edge. Analysis of the photoluminescence lineshape at low temperature presents strong evidence for a Gaussian distribution of localised states that extends from the valence band edge. Furthermore, a rate model is employed to understand the non-uniform thermal quenching of the photoluminescence and indicates the presence of two Gaussian-like distributions making up the density of localised states. These components are attributed to the presence of microscopic fluctuations in Bi content, due to short-range alloy disorder across the GaAsBi layer, and the formation of Bi related point defects, resulting from low temperature growth.

  2. Damage localisation and fracture propagation in granite: 4D synchrotron x-ray microtomographic observations from an in-situ triaxial deformation experiment at SOLEIL

    NASA Astrophysics Data System (ADS)

    Cartwright-Taylor, Alexis; Fusseis, Florian; Butler, Ian; Flynn, Michael; King, Andrew

    2017-04-01

    To date, most studies of damage localisation and failure have utilised indirect techniques to visualise the pathway to failure. The advent of synchrotron tomography and x-ray transparent experimental cells provides for the first time the opportunity to image localisation and fracture propagation in-situ, in real time with spatial resolutions of a few microns. We present 4D x-ray microtomographic data collected during a triaxial deformation experiment carried out at the imaging beamline PSICHE at the French Synchrotron SOLEIL. The data document damage localisation and fracture propagation in a microgranite. The sample was deformed at 15 MPa confining pressure and 3x10-5 s-1 strain rate, in a novel, miniature, x-ray transparent, triaxial deformation apparatus, designed and built at the University of Edinburgh. We used a 2.97 mm diameter x 9.46 mm long cylindrical sample of Ailsa Craig microgranite, heat treated to 600 ˚ C to introduce flaws in the form of pervasive crack damage. As the sample was loaded to failure, 21 microtomographic volumes were acquired in intervals of 5-20 MPa (decreasing as failure approached), including one scan at peak differential stress of 200 MPa (1.4 kN end load) and three post-failure scans. The scan at peak stress contained the incipient fault, and the sample failed immediately when loading continued afterwards. During scanning, a constant stress level was maintained. Individual datasets were collected in ˜10 minutes using a white beam with an energy maximum at 66 keV in a spiral configuration. Reconstructions yielded image stacks with a dimension of 1700x1700x4102 voxels with a voxel size of 2.7 μm. We analysed damage localisation and fracture propagation in the time series data. Fractures were segmented from the image data using a Multiscale Hessian fracture filter [1] and analysed for their orientations, dimensions and spatial distributions and changes in these properties during loading. Local changes in volumetric and shear strains between time steps were quantified using 3D digital image correlation [2]. In combination, these analyses show the extent and evolution of local aseismic deformation and that related to microcracking. Our results provide direct evidence of ongoing deformation processes such as micro-fracture nucleation at pre-existing flaws, in the form of cracks, grain boundaries and pores, and coalescence of en-echelon tensile micro-fractures along a shear fault in response to changes in the local stress field. These direct 4D observations of damage evolution and strain localisation complement the seminal results of Lockner et al. [3], who first imaged the process of fault growth using acoustic emissions locations. Our data provide further insight into the aseismic mechanisms that dissipate 99% of the total accumulated strain energy [4] and the interactions between these mechanisms and the developing microcracks. Our results also provide experimental verification of models for shear fracture formation whereby pre-existing flaws become connected by en-echelon tensile cracks that extend from their edges. _________________________________________ [1] Voorn et al., 2015, J. Petroleum Sci. Eng. 127, 270-285. [2] Hall, S. et al., 2010, Geotechnique 60, 315-322. [3] Lockner, D., et al., 1991, Nature 350, 39-42. [4] Byerlee, J., 1993, Geology 21, 303-306.

  3. 18 CFR 376.209 - Procedures during periods of emergency requiring activation of the Continuity of Operations Plan.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... major wire services, industry press, and appropriate metropolitan area radio stations announcing that... Internet Web site, the Transmission Provide may, for 30 days, also delay compliance with the requirements of § 358.4(a)(2) of this chapter to post this information on the OASIS or Internet Web site, as...

  4. 10. VIEW EAST (93 DEGREES) OF RCA COMMUNICATION RECEIVING STATION. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. VIEW EAST (93 DEGREES) OF RCA COMMUNICATION RECEIVING STATION. WOOD FRAMING SUPPORTED STANDOFF INSULATORS AND ANTENNA WIRES COMING FROM THE FIELD INTO THE BUILDING. BOLT ON FOUNDATION POLES SUPPORTED SATELLITE ANTENNAS, METAL CAP AND POSTS AT LEFT PROTECTED CONDUIT SUPPLYING POWER TO SATELLITE ANTENNA MOTORS. - Marconi Radio Sites, Receiving, Point Reyes Station, Marin County, CA

  5. Luminous Lighting: In This STEAM Activity, Students Create Wire Sculptures That Light up

    ERIC Educational Resources Information Center

    Grinnell, Sandie; Angal, Sharon

    2016-01-01

    In a 2012 blog post, John Maeda discusses the idea that while science, technology, engineering, and mathematics (STEM) education plays an important role in innovation, limitations exist when we focus exclusively on STEM. Maeda advocates for the addition of the "A" for Art to the acronym, insisting that the arts promote the creativity and…

  6. 99mTc-EDDA/HYNIC-TOC and (18)F-FDG in thyroid cancer patients with negative (131)I whole-body scans.

    PubMed

    Gabriel, Michael; Froehlich, Franz; Decristoforo, Clemens; Ensinger, Christian; Donnemiller, Eveline; von Guggenberg, Elisabeth; Heute, Dirk; Moncayo, Roy

    2004-03-01

    Several studies have reported on the expression of somatostatin receptors in patients with differentiated thyroid cancer (DTC). The aim of this study was to evaluate the imaging abilities of a recently developed technetium-99m labelled somatostatin analogue, (99m)Tc-EDDA/HYNIC-TOC ((99m)Tc-TOC), in terms of precise localisation of disease. The study population comprised 54 patients (24 men, 30 women; age range 22-90 years) with histologically confirmed DTC who presented with recurrent or persistent disease as indicated by elevated Tg levels after initial treatment. All patients were negative on the iodine-131 post-therapy whole-body scans. Fluorine-18 fluorodeoxyglucose positron emission tomography ((18)F-FDG PET) was performed in a subgroup of 36 patients. The study population consisted of two groups: Group A ( n=22) comprised patients with disease recurrence as shown by elevated Tg levels but without detectable pathology. In group B ( n=32), pre-existing lesions were known. Among the 54 cases, SSTR scintigraphy was true positive in 33 (61.1%), true negative in 4 (7.4%) and false negative in 17 (31.5%) cases, which resulted in a sensitivity of 66%. A total of 138 tumour foci were localised in 33 patients. The fraction of true positive (99m)Tc-TOC findings was positively correlated ( P<0.01) with elevated Tg levels (higher than 30 ng/ml). Despite two false positive findings, analysis on a lesion basis demonstrated better diagnostic efficacy with (18)F-FDG PET ( P<0.001); however, it also revealed substantial agreement between the imaging techniques [Cohen's kappa of 0.62 (0.47-0.78)]. In conclusion, scintigraphy with (99m)Tc-TOC might be a promising tool for treatment planning; it is easy to perform and showed sufficient accuracy for localisation diagnostics in thyroid cancer patients with recurrent or metastatic disease.

  7. Prognostic significance of SUV on PET/CT in patients with localised oesophagogastric junction cancer receiving neoadjuvant chemotherapy/chemoradiation:a systematic review and meta-analysis.

    PubMed

    Zhu, W; Xing, L; Yue, J; Sun, X; Sun, X; Zhao, H; Yu, J

    2012-09-01

    The objective of this study was to comprehensively review the evidence for use of pre-treatment, post-treatment and changes in tumour glucose uptake that were assessed by 18-fludeoxyglucose ((18)F-FDG) positron emission tomography (PET) early, during or immediately after neoadjuvant chemotherapy/chemoradiation to predict prognosis of localised oesophagogastric junction (AEG) cancer. We searched for articles published in English; limited to AEG; (18)F-FDG uptake on PET performed on a dedicated device; dealt with the impact of standard uptake value (SUV) on survival. We extracted an estimate of the log hazard ratios (HRs) and their variances and performed meta-analysis. 798 patients with AEG were included. And the scan time for (18)F-FDG-PET was as follows: prior to therapy (PET1, n=646), exactly 2 weeks after initiation of neoadjuvant therapy (PET2, n=245), and pre-operatively (PET3, n=278). In the two meta-analyses for overall survival, including the studies that dealt with reduction of tumour maximum SUV (SUV(max)) (from PET1 to PET2/PET3 and from PET1 to PET2), the results were similar, with the overall HR for non-responders being 1.83 [95% confidence interval (CI), 1.41-2.36] and 2.62 (95% CI, 1.61-4.26), respectively; as for disease-free survival, the combined HR was 2.92 (95% CI, 2.08-4.10) and 2.39 (95% CI, 1.57-3.64), respectively. The meta-analyses did not attribute significant prognostic values to SUV(max) before and during therapy in localised AEG. Relative changes in FDG-uptake of AEG are better prognosticators. Early metabolic changes from PET1 to PET2 may provide the same accuracy for prediction of treatment outcome as late changes from PET1 to PET3.

  8. Enantioselective cellular localisation of europium(iii) coordination complexes† †Electronic supplementary information (ESI) available: Complex synthesis and characterisation, selected cell images showing correspondence with commercial lysosomal or mitochondrial stains and spectral imaging profiles. See DOI: 10.1039/c7sc04422d

    PubMed Central

    Frawley, Andrew T.; Linford, Holly V.; Starck, Matthieu; Pal, Robert

    2017-01-01

    The selective mitochondrial localisation of the Λ enantiomer of three different emissive europium(iii) complexes in NIH 3T3 and MCF7 cells contrasts with the behaviour of the Δ enantiomer, for which a predominant lysosomal localisation was observed by confocal microscopy. In each case, cell uptake occurs via macropinocytosis. PMID:29675151

  9. Minimally invasive fluoroscopic percutaneous peritoneal dialysis catheter salvage.

    PubMed

    Narayan, Rajeev; Fried, Terrance; Chica, Gerardo; Schaefer, Mathew; Mullins, Daniel

    2014-06-01

    Peritoneal dialysis catheter (PDC) dysfunction can often be treated fluoroscopically by manipulation with wire, balloon or stiff stylet, saving surgical intervention for refractory cases. We describe an enhanced percutaneous approach to PDC salvage that can lead to a more definitive intervention and salvage for cases refractory to fluoroscopic manipulation. In five cases of PD catheter malfunction, the deep cuff was dissected free after a 0.035 hydrophilic wire was passed into the peritoneum through the PDC. Only the intraperitoneal portion of the PDC was explanted. The PDC was cleared of obstruction and omentum. The intraperitoneal portion of the PDC was reimplanted over wire via a peel-away sheath and the deep cuff sutured. Omental entrapment was present in three of five patients and fibrin occlusion in four of the five cases. All catheters were repaired successfully by the described technique. Post procedure, 3-5 days of lower volume, recumbent PD exchanges were performed prior to full-dose PD. No perioperative complications or leaks were noted. All PDCs were patent at 6 months. One patient required laparoscopy for recurrent omental wrapping 3 months post intervention. PDC salvage in this manner is a cost-effective alternative to laparoscopic repair of PDCs failing catheter manipulation. The infection barrier afforded by the original superficial cuff and subcutaneous tunnel is maintained. PD can be resumed immediately. Only refractory cases need laparoscopy. This procedure allows for a more definitive correction of catheter migration and obstruction, avoids placement of a new PDC or temporary hemodialysis, is cost-effective and expands percutaneous options for dysfunctional PD catheters.

  10. Debris extrusion and foraminal deformation produced by reciprocating instruments made of thermally treated NiTi wires.

    PubMed

    Frota, Myrna Maria Arcanjo; Bernardes, Ricardo Affonso; Vivan, Rodrigo Ricci; Vivacqua-Gomes, Nilton; Duarte, Marco Antonio Hungaro; Vasconcelos, Bruno Carvalho de

    2018-01-18

    To evaluate the amount of apically extruded debris, percentage of foraminal enlargement and apical foramen (AF) deformation that occurred during root canal preparation with different reciprocation systems: Reciproc, WaveOne (M-Wire), and ProDesign R (Shape Memory Technology Wire) at two different working lengths (WLs): 0.0 and 1.0 mm beyond the AF. The AF of 120 root canals in 60 mesial roots of mandibular molars were photographed with stereomicroscope and randomly assigned into four groups: manual, Reciproc (REC), WaveOne (WO), and ProDesign R (PDR); subsequently, they were further subdivided according to the WL (n=15). Teeth were instrumented, coupled to a dual collecting chamber, and then another photograph of each AF was captured. Extrusion was analysed by determining the weight of extruded debris. Each AF diameter was measured in pre- and post-instrumentation images to determine deformation, which was analysed, and afterwards the final format of AFs was classified (circular/oval/deformed). We found no significant differences when analysing each system at different WLs. When considering each WL, REC and WO showed highest extrusion values (P<.05); for AF enlargement, differences were observed only for WO, when it was used beyond the AF; differences were observed among M-Wire groups beyond the AF (P<.05). AF deformation was observed in all groups; PDR showed the lowest AF deformation values at both WLs; M-Wire groups showed 50% strain beyond the AF. Authors concluded that beyond the apical limit, the alloy and taper are important aspects when considering extrusion and deformation.

  11. Factors associated with current and severe physical side-effects after prostate cancer treatment: What men report.

    PubMed

    Steentjes, L; Siesling, S; Drummond, F J; van Manen, J G; Sharp, L; Gavin, A

    2018-01-01

    We identified patient and disease characteristics associated with (1) "current" physical side-effects of any severity; and (2) "severe" physical side-effects "ever" experienced by 3,348 (54%) prostate cancer (PCa) survivors in Ireland diagnosed 2-18 years previously. Postal questionnaires collected symptoms at diagnosis, post-biopsy complications, comorbidities, primary treatments and physical side-effects post-treatment (urinary incontinence, erectile dysfunction, libido loss, bowel problems, breast changes, hot flushes, and fatigue, "ever" and "current" at time of questionnaire completion). Men were grouped by "early" (localised) and "late" (locally advanced/advanced) disease at diagnosis. Multivariable logistic regression analysis identified patient and disease-related factors associated with post-treatment side-effects. Complications post-biopsy were associated with higher risk of "current" libido loss and impotence. Radical prostatectomy was associated with higher risk of "current" and "severe" incontinence, libido loss and impotence in both early and late disease. In early disease, brachytherapy was associated with lower risk of "current" fatigue and "severe" impotence. Comorbidities were associated with higher risk of "current" experience of four side-effects (incontinence, libido loss, bowel problems, fatigue). Men on active surveillance/watchful-waiting reported lower risk of sexual dysfunction. These findings could inform development of tailored information on side-effects, which, in turn, could inform treatment decision-making and post-treatment monitoring. © 2016 John Wiley & Sons Ltd.

  12. Dynamic control of laser driven proton beams by exploiting self-generated, ultrashort electromagnetic pulses

    NASA Astrophysics Data System (ADS)

    Kar, S.; Ahmed, H.; Nersisyan, G.; Brauckmann, S.; Hanton, F.; Giesecke, A. L.; Naughton, K.; Willi, O.; Lewis, C. L. S.; Borghesi, M.

    2016-05-01

    As part of the ultrafast charge dynamics initiated by high intensity laser irradiations of solid targets, high amplitude EM pulses propagate away from the interaction point and are transported along any stalks and wires attached to the target. The propagation of these high amplitude pulses along a thin wire connected to a laser irradiated target was diagnosed via the proton radiography technique, measuring a pulse duration of ˜20 ps and a pulse velocity close to the speed of light. The strong electric field associated with the EM pulse can be exploited for controlling dynamically the proton beams produced from a laser-driven source. Chromatic divergence control of broadband laser driven protons (upto 75% reduction in divergence of >5 MeV protons) was obtained by winding the supporting wire around the proton beam axis to create a helical coil structure. In addition to providing focussing and energy selection, the technique has the potential to post-accelerate the transiting protons by the longitudinal component of the curved electric field lines produced by the helical coil lens.

  13. Dynamic control of laser driven proton beams by exploiting self-generated, ultrashort electromagnetic pulses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kar, S., E-mail: s.kar@qub.ac.uk; Ahmed, H.; Nersisyan, G.

    As part of the ultrafast charge dynamics initiated by high intensity laser irradiations of solid targets, high amplitude EM pulses propagate away from the interaction point and are transported along any stalks and wires attached to the target. The propagation of these high amplitude pulses along a thin wire connected to a laser irradiated target was diagnosed via the proton radiography technique, measuring a pulse duration of ∼20 ps and a pulse velocity close to the speed of light. The strong electric field associated with the EM pulse can be exploited for controlling dynamically the proton beams produced from amore » laser-driven source. Chromatic divergence control of broadband laser driven protons (upto 75% reduction in divergence of >5 MeV protons) was obtained by winding the supporting wire around the proton beam axis to create a helical coil structure. In addition to providing focussing and energy selection, the technique has the potential to post-accelerate the transiting protons by the longitudinal component of the curved electric field lines produced by the helical coil lens.« less

  14. Model assessing thermal changes during high temperature root canal irrigation

    PubMed Central

    Bartolo, Analise; Koyess, Edmond; Micallef, Christopher

    2016-01-01

    The main aim of root canal irrigation is to eliminate micro-organisms. Sodium hypochlorite (NaOCl) is considered to be the ideal material and raising its temperature potentiates the antimicrobial activity. NaOCl may lead to localised tissue necrosis when extruded past the root apex. This study analyses the use of high temperature root canal irrigation as an alternative process for the elimination of microorganisms from the root canal system. An experimental set-up was designed where a constant supply of heat was passed from a heat source through a copper wire inside the root canal. The data acquired together with known constants pertaining to enamel and dentine was used to numerically model the thermal changes in a tooth using a finite element method. Results obtained from the finite element thermal model of the tooth were repeatable and were validated with the experimental results. The thermo-physical properties of the tooth were varied and convergence criteria met. The temperatures reached were below what has been reported to cause irreversible damage to the bone. This was further confirmed from a series of simulations that were undertaken. The temperatures achieved were suitable for the elimination of microorganisms during root canal therapy. PMID:27733934

  15. Evidence of phase nucleation during olivine diffusion creep: a new perspective for mantle strain localisation

    NASA Astrophysics Data System (ADS)

    Précigout, Jacques; Stünitz, Holger

    2017-04-01

    Mantle strain localisation is of great importance for lithosphere dynamics, but the cause for this phenomenon remains very elusive, particularly in conditions of the strong and ductile uppermost mantle. In these latter, grain size reduction leading to diffusion creep in olivine is believed to be one of the best candidates to account for strain localisation. However, the mechanisms of grain size reduction in this regime are still poorly understood. Here we show the results of Griggs-type experiments that document grain size reduction and material weakening during wet olivine diffusion creep at 900 °C and 1.2 GPa. While occurring for both, mono-phase and two-phase aggregates, grain size reduction is coeval with strain localisation and local phase mixing in olivine-pyroxene aggregates. Based on evidence of fluid inclusions and cracks filled with a fine-grained phase mixture, we conclude that grain size reduces as a result of fluid-assisted nucleation. Cavitation induced by grain boundary sliding (creep cavitation) can be inferred, and may play a critical role for olivine grain size reduction. Amongst their implications for rock rheology in general, our findings highlight a key process for strain localisation in the ductile uppermost mantle. This study has been published under the reference: "Précigout, J., and Stünitz, H. (2016) Evidence of phase nucleation during olivine diffusion creep: a new perspective for mantle strain localisation. Earth and Planetary Science Letters 455: 94-105, doi:101016/j.epsl.2016.09.029".

  16. KPNA2 is a nuclear export protein that contributes to aberrant localisation of key proteins and poor prognosis of breast cancer.

    PubMed

    Alshareeda, A T; Negm, O H; Green, A R; Nolan, C C; Tighe, P; Albarakati, N; Sultana, R; Madhusudan, S; Ellis, I O; Rakha, E A

    2015-06-09

    It is recognised that modulations of the nuclear import of macromolecules have a role in changing cellular phenotypes and carcinogenesis. We and others have noticed that aberrant subcellular localisation of DNA damage response (DDR) proteins in breast cancer (BC) is associated with loss-of-function phenotype. This study aims to investigate the biological and clinical significance of the nucleocytoplasmic transport protein karyopherin α-2 (KPNA2), and its role in controlling DDR proteins subcellular localisation in BC. A large (n=1494) and well-characterised series of early-stage invasive BC with a long-term follow-up was assessed for KPNA2 protein by using immunohistochemistry. KPNA2 expression was associated with the subcellular localisation of key DDR proteins that showed cytoplasmic expression including BRCA1, RAD51, SMC6L1, γH2AX, BARD1, UBC9, PIAS1 and CHK1. High level of KPNA2 was associated not only with cytoplasmic localisation of these proteins but also with their low/negative nuclear expression. Positive KPNA2 expression was associated with negative oestrogen receptor and triple-negative phenotype. Survival analysis showed that KPNA2 was associated with poor outcome (P<0.0001), but this effect was not independent of other prognostic variables. This study provides further evidence for the complexity of DDR mechanism in BC, and that KNPA2 has a role in the aberrant subcellular localisation of DDR proteins with subsequent impaired function.

  17. Passive RFID Rotation Dimension Reduction via Aggregation

    NASA Astrophysics Data System (ADS)

    Matthews, Eric

    Radio Frequency IDentification (RFID) has applications in object identification, position, and orientation tracking. RFID technology can be applied in hospitals for patient and equipment tracking, stores and warehouses for product tracking, robots for self-localisation, tracking hazardous materials, or locating any other desired object. Efficient and accurate algorithms that perform localisation are required to extract meaningful data beyond simple identification. A Received Signal Strength Indicator (RSSI) is the strength of a received radio frequency signal used to localise passive and active RFID tags. Many factors affect RSSI such as reflections, tag rotation in 3D space, and obstacles blocking line-of-sight. LANDMARC is a statistical method for estimating tag location based on a target tag's similarity to surrounding reference tags. LANDMARC does not take into account the rotation of the target tag. By either aggregating multiple reference tag positions at various rotations, or by determining a rotation value for a newly read tag, we can perform an expected value calculation based on a comparison to the k-most similar training samples via an algorithm called K-Nearest Neighbours (KNN) more accurately. By choosing the average as the aggregation function, we improve the relative accuracy of single-rotation LANDMARC localisation by 10%, and any-rotation localisation by 20%.

  18. Immunogold staining procedure for the localisation of regulatory peptides.

    PubMed

    Varndell, I M; Tapia, F J; Probert, L; Buchan, A M; Gu, J; De Mey, J; Bloom, S R; Polak, J M

    1982-01-01

    The use of protein A- and IgG-conjugated colloidal gold staining methods for the immuno-localisation of peptide hormones and neurotransmitters at light- and electron microscope level are described and discussed. Bright-field and dark-ground illumination modes have been used to visualise the gold-labelled antigenic sites at the light microscope level. Immunogold staining procedures at the ultrastructural level using region-specific antisera have been adopted to localise specific molecular forms of peptides including gastrin (G17 and G34), glucagon and pro-glucagon, insulin and pro-insulin, in normal tissue and in tumours of the gastroenteropancreatic system. Similar methods have been used to demonstrate the heterogeneity of p-type nerves in the enteric nervous system. Vasoactive intestinal polypeptide (VIP) has been localised to granular sites (mean +/- S.D. granule diameter = 98 +/- 19 nm) in nerve terminals of the enteric plexuses and in tumour cells of diarrhoeogenic VIP-producing neoplasias (mean +/- S.D. granule diameter = 126 +/- 37 nm) using immunogold procedures applied to ultraviolet-cured ultrathin sections. Co-localisation of amines and peptides in carotid body type I cells and in chromaffin cells of normal adrenal medulla and phaeochromocytomas has also been demonstrated. Advantages of the immunogold procedures over alternative immunocytochemical techniques are discussed.

  19. Basolateral localisation of KCNQ1 potassium channels in MDCK cells: molecular identification of an N-terminal targeting motif.

    PubMed

    Jespersen, Thomas; Rasmussen, Hanne B; Grunnet, Morten; Jensen, Henrik S; Angelo, Kamilla; Dupuis, Delphine S; Vogel, Lotte K; Jorgensen, Nanna K; Klaerke, Dan A; Olesen, Søren-Peter

    2004-09-01

    KCNQ1 potassium channels are expressed in many epithelial tissues as well as in the heart. In epithelia KCNQ1 channels play an important role in salt and water transport and the channel has been reported to be located apically in some cell types and basolaterally in others. Here we show that KCNQ1 channels are located basolaterally when expressed in polarised MDCK cells. The basolateral localisation of KCNQ1 is not affected by co-expression of any of the five KCNE beta-subunits. We characterise two independent basolateral sorting signals present in the N-terminal tail of KCNQ1. Mutation of the tyrosine residue at position 51 resulted in a non-polarized steady-state distribution of the channel. The importance of tyrosine 51 in basolateral localisation was emphasized by the fact that a short peptide comprising this tyrosine was able to redirect the p75 neurotrophin receptor, an otherwise apically located protein, to the basolateral plasma membrane. Furthermore, a di-leucine-like motif at residues 38-40 (LEL) was found to affect the basolateral localisation of KCNQ1. Mutation of these two leucines resulted in a primarily intracellular localisation of the channel.

  20. Non-Gaussian probabilistic MEG source localisation based on kernel density estimation☆

    PubMed Central

    Mohseni, Hamid R.; Kringelbach, Morten L.; Woolrich, Mark W.; Baker, Adam; Aziz, Tipu Z.; Probert-Smith, Penny

    2014-01-01

    There is strong evidence to suggest that data recorded from magnetoencephalography (MEG) follows a non-Gaussian distribution. However, existing standard methods for source localisation model the data using only second order statistics, and therefore use the inherent assumption of a Gaussian distribution. In this paper, we present a new general method for non-Gaussian source estimation of stationary signals for localising brain activity from MEG data. By providing a Bayesian formulation for MEG source localisation, we show that the source probability density function (pdf), which is not necessarily Gaussian, can be estimated using multivariate kernel density estimators. In the case of Gaussian data, the solution of the method is equivalent to that of widely used linearly constrained minimum variance (LCMV) beamformer. The method is also extended to handle data with highly correlated sources using the marginal distribution of the estimated joint distribution, which, in the case of Gaussian measurements, corresponds to the null-beamformer. The proposed non-Gaussian source localisation approach is shown to give better spatial estimates than the LCMV beamformer, both in simulations incorporating non-Gaussian signals, and in real MEG measurements of auditory and visual evoked responses, where the highly correlated sources are known to be difficult to estimate. PMID:24055702

  1. Domains involved in calcineurin phosphatase inhibition and nuclear localisation in the African swine fever virus A238L protein

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abrams, Charles C.; Chapman, Dave A.G.; Silk, Rhiannon

    2008-05-10

    The African swine fever virus A238L protein inhibits calcineurin phosphatase activity and activation of NF-{kappa}B and p300 co-activator. An 82 amino acid domain containing residues 157 to 238 at the C-terminus of A238L was expressed in E. coli and purified. This purified A238L fragment acted as a potent inhibitor of calcineurin phosphatase in vitro with an IC{sub 50} of approximately 70 nM. Two putative nuclear localisation signals were identified between residues 80 to 86 (NLS-1) and between residues 203 to 207 overlapping with the N-terminus of the calcineurin docking motif (NLS-2). Mutation of these motifs independently did not reduce nuclearmore » localisation compared to the wild type A238L protein, whereas mutation of both motifs significantly reduced nuclear localisation of A238L. Mutation of the calcineurin docking motif resulted in a dramatic increase in the nuclear localisation of A238L provided an intact NLS was present. We propose that binding of calcineurin to A238L masks NLS-2 contributing to the cytoplasmic retention of A238L.« less

  2. Control of E-cadherin apical localisation and morphogenesis by a SOAP-1/AP-1/clathrin pathway in C. elegans epidermal cells.

    PubMed

    Gillard, Ghislain; Shafaq-Zadah, Massiullah; Nicolle, Ophélie; Damaj, Raghida; Pécréaux, Jacques; Michaux, Grégoire

    2015-05-01

    E-cadherin (E-cad) is the main component of epithelial junctions in multicellular organisms, where it is essential for cell-cell adhesion. The localisation of E-cad is often strongly polarised in the apico-basal axis. However, the mechanisms required for its polarised distribution are still largely unknown. We performed a systematic RNAi screen in vivo to identify genes required for the strict E-cad apical localisation in C. elegans epithelial epidermal cells. We found that the loss of clathrin, its adaptor AP-1 and the AP-1 interactor SOAP-1 induced a basolateral localisation of E-cad without affecting the apico-basal diffusion barrier. We further found that SOAP-1 controls AP-1 localisation, and that AP-1 is required for clathrin recruitment. Finally, we also show that AP-1 controls E-cad apical delivery and actin organisation during embryonic elongation, the final morphogenetic step of embryogenesis. We therefore propose that a molecular pathway, containing SOAP-1, AP-1 and clathrin, controls the apical delivery of E-cad and morphogenesis. © 2015. Published by The Company of Biologists Ltd.

  3. Electromagnetic panel deployment and retraction using the geomagnetic field in LEO satellite missions

    NASA Astrophysics Data System (ADS)

    Inamori, Takaya; Sugawara, Yoshiki; Satou, Yasutaka

    2015-12-01

    Increasingly, spacecraft are installed with large-area structures that are extended and deployed post-launch. These extensible structures have been applied in several missions for power generation, thermal radiation, and solar propulsion. Here, we propose a deployment and retraction method using the electromagnetic force generated when the geomagnetic field interacts with electric current flowing on extensible panels. The panels are installed on a satellite in low Earth orbit. Specifically, electrical wires placed on the extensible panels generate magnetic moments, which interfere with the geomagnetic field. The resulting repulsive and retraction forces enable panel deployment and retraction. In the proposed method, a satellite realizes structural deployment using simple electrical wires. Furthermore, the satellite can achieve not only deployment but also retraction for avoiding damage from space debris and for agile attitude maneuvers. Moreover, because the proposed method realizes quasi-static deployment and the retraction of panels by electromagnetic forces, low impulsive force is exerted on fragile panels. The electrical wires can also be used to detect the panel deployment and retraction and generate a large magnetic moment for attitude control. The proposed method was assessed in numerical simulations based on multibody dynamics. Simulation results shows that a small cubic satellite with a wire current of 25 AT deployed 4 panels (20 cm × 20 cm) in 500 s and retracted 4 panels in 100 s.

  4. Radiological and Functional Outcome of Displaced Colles’ Fracture Managed with Closed Reduction and Percutaneous Pinning: A Prospective Study

    PubMed Central

    Khatri, Kishor; Kharel, Krishna; Byanjankar, Subin; Sharma, Jay R; Shrestha, Rahul; Vaishya, Raju; Agarwal, Amit Kumar; Vijay, Vipul

    2017-01-01

    Background: Displaced Colles’ fractures are treated by manipulation and below elbow cast application. Malunion is a common complication, resulting in pain, mid-carpal instability, and post-traumatic arthritis. Fracture stabilization by percutaneous pinning is a simple, minimally invasive technique that helps prevent displacement of the fracture, thereby minimizing complications. This study aims to assess the amount of collapse after closed manipulation and percutaneous pinning with Kirschner wires (K-wires) and its correlation with the functional outcome of the wrist after union. Methods: A prospective study was conducted from May 2015 to May 2016 in a tertiary orthopedic center. Ninety patients (60 females, 30 males) with an average age of 54.93 years with Type II fractures underwent closed manipulation and percutaneous pinning with crossed K-wires as the primary procedure. Serial radiographs were taken to document the amount of collapse. The functional outcome was assessed using the Cooney Wrist Score. Results: At the final follow-up at six months, the collapse in the mean dorsal angle was 0.94 and mean ulnar variance was 0.51. Functionally, 48 patients (53.33%) had an excellent outcome, 36 patients (40%) had a good outcome, and six patients (6.67%) had a fair outcome. Conclusions: Displaced Colles’ fractures should be reduced and stabilized with percutaneous K-wires to achieve an excellent functional outcome. PMID:28191366

  5. Radiological and Functional Outcome of Displaced Colles' Fracture Managed with Closed Reduction and Percutaneous Pinning: A Prospective Study.

    PubMed

    Panthi, Sagar; Khatri, Kishor; Kharel, Krishna; Byanjankar, Subin; Sharma, Jay R; Shrestha, Rahul; Vaishya, Raju; Agarwal, Amit Kumar; Vijay, Vipul

    2017-01-06

    Displaced Colles' fractures are treated by manipulation and below elbow cast application. Malunion is a common complication, resulting in pain, mid-carpal instability, and post-traumatic arthritis. Fracture stabilization by percutaneous pinning is a simple, minimally invasive technique that helps prevent displacement of the fracture, thereby minimizing complications. This study aims to assess the amount of collapse after closed manipulation and percutaneous pinning with Kirschner wires (K-wires) and its correlation with the functional outcome of the wrist after union. A prospective study was conducted from May 2015 to May 2016 in a tertiary orthopedic center. Ninety patients (60 females, 30 males) with an average age of 54.93 years with Type II fractures underwent closed manipulation and percutaneous pinning with crossed K-wires as the primary procedure. Serial radiographs were taken to document the amount of collapse. The functional outcome was assessed using the Cooney Wrist Score. At the final follow-up at six months, the collapse in the mean dorsal angle was 0.94 and mean ulnar variance was 0.51. Functionally, 48 patients (53.33%) had an excellent outcome, 36 patients (40%) had a good outcome, and six patients (6.67%) had a fair outcome. Displaced Colles' fractures should be reduced and stabilized with percutaneous K-wires to achieve an excellent functional outcome.

  6. Installation of a reactive site for covalent wiring onto an intrinsically conductive poly(ionic liquid)

    DOE PAGES

    Brombosz, Scott M.; Lee, Sungwon; Firestone, Millicent A.

    2014-11-04

    We describe post-polymerization radical bromination of a nanostructured poly(ionic liquid) that selectively introduces a reactive bromo-group onto the polyalkylthiophene backbone. Raman and FT-IR spectroscopy proves that the bromine is successfully introduced at the 3-methyl position of the thiophene and that the molecular structure of the polymer remains largely intact with only minimal chain scission detected. FT-IR and Vis-NIR spectroscopy indicates that incorporation of the bromine induces twisting (loss of co-planarity) of the polythiophene backbone. WAXS confirms retention of an ordered lamellar structure with minor lattice spacing contraction. Cyclic voltammetry confirms spectroscopic findings that the bromination reaction yields a stable p-dopedmore » polymer. The installed bromine is susceptible to nucleophilic displacement permitting the covalent attachment of other functional molecules, such as a dialkylphosphonate. Elemental analysis of such a transformation established that 100 % functionalization can be achieved. These results collectively demonstrate that post-modification of a π-conjugated polymer can be used to both tune electronic and photonic properties, as well as install a chemoselective attachment point for the covalent wiring of other molecules.« less

  7. Divergent RNA Localisation Patterns of Maternal Genes Regulating Embryonic Patterning in the Butterfly Pararge aegeria

    PubMed Central

    Carter, Jean-Michel; Gibbs, Melanie; Breuker, Casper J.

    2015-01-01

    The maternal effect genes responsible for patterning the embryo along the antero-posterior (AP) axis are broadly conserved in insects. The precise function of these maternal effect genes is the result of the localisation of their mRNA in the oocyte. The main developmental mechanisms involved have been elucidated in Drosophila melanogaster, but recent studies have shown that other insect orders often diverge in RNA localisation patterns. A recent study has shown that in the butterfly Pararge aegeria the distinction between blastodermal embryonic (i.e. germ band) and extra-embryonic tissue (i.e. serosa) is already specified in the oocyte during oogenesis in the ovariole, long before blastoderm cellularisation. To examine the extent by which a female butterfly specifies and patterns the AP axis within the region fated to be the germ band, and whether she specifies a germ plasm, we performed in situ hybridisation experiments on oocytes in P. aegeria ovarioles and on early embryos. RNA localisation of the following key maternal effect genes were investigated: caudal (cad), orthodenticle (otd), hunchback (hb) and four nanos (nos) paralogs, as well as TDRD7 a gene containing a key functional domain (OST-HTH/LOTUS) shared with oskar. TDRD7 was mainly confined to the follicle cells, whilst hb was exclusively zygotically transcribed. RNA of some of the nos paralogs, otd and cad revealed complex localisation patterns within the cortical region prefiguring the germ band (i.e. germ cortex). Rather interestingly, otd was localised within and outside the anterior of the germ cortex. Transcripts of nos-O formed a distinct granular ring in the middle of the germ cortex possibly prefiguring the region where germline stem cells form. These butterfly RNA localisation patterns are highly divergent with respect to other insects, highlighting the diverse ways in which different insect orders maternally regulate early embryogenesis of their offspring. PMID:26633019

  8. Improvement of localised corrosion resistance of AISI 2205 Duplex Stainless Steel joints made by gas metal arc welding under electromagnetic interaction of low intensity

    NASA Astrophysics Data System (ADS)

    García-Rentería, M. A.; López-Morelos, V. H.; García-Hernández, R.; Dzib-Pérez, L.; García-Ochoa, E. M.; González-Sánchez, J.

    2014-12-01

    The resistance to localised corrosion of AISI 2205 duplex stainless steel plates joined by Gas Metal Arc Welding (GMAW) under the effect of electromagnetic interaction of low intensity (EMILI) was evaluated with sensitive electrochemical methods. Welds were made using two shielding gas mixtures: 98% Ar + 2% O2 (M1) and 97% Ar + 3% N2 (M2). Plates were welded under EMILI using the M1 gas with constant welding parameters. The modified microstructural evolution in the high temperature heat affected zone and at the fusion zone induced by application of EMILI during welding is associated with the increase of resistance to localised corrosion of the welded joints. Joints made by GMAW using the shielding gas M2 without the application of magnetic field presented high resistance to general corrosion but high susceptibility to undergo localised attack.

  9. Differences in finger localisation performance of patients with finger agnosia.

    PubMed

    Anema, Helen A; Kessels, Roy P C; de Haan, Edward H F; Kappelle, L Jaap; Leijten, Frans S; van Zandvoort, Martine J E; Dijkerman, H Chris

    2008-09-17

    Several neuropsychological studies have suggested parallel processing of somatosensory input when localising a tactile stimulus on one's own by pointing towards it (body schema) and when localising this touched location by pointing to it on a map of a hand (body image). Usually these reports describe patients with impaired detection, but intact sensorimotor localisation. This study examined three patients with a lesion of the angular gyrus with intact somatosensory processing, but with selectively disturbed finger identification (finger agnosia). These patients performed normally when pointing towards the touched finger on their own hand but failed to indicate this finger on a drawing of a hand or to name it. Similar defects in the perception of other body parts were not observed. The findings provide converging evidence for the dissociation between body image and body schema and, more importantly, reveal for the first time that this distinction is also present in higher-order cognitive processes selectively for the fingers.

  10. Flows and Stratification of an Enclosure Containing Both Localised and Vertically Distributed Sources of Buoyancy

    NASA Astrophysics Data System (ADS)

    Partridge, Jamie; Linden, Paul

    2013-11-01

    We examine the flows and stratification established in a naturally ventilated enclosure containing both a localised and vertically distributed source of buoyancy. The enclosure is ventilated through upper and lower openings which connect the space to an external ambient. Small scale laboratory experiments were carried out with water as the working medium and buoyancy being driven directly by temperature differences. A point source plume gave localised heating while the distributed source was driven by a controllable heater mat located in the side wall of the enclosure. The transient temperatures, as well as steady state temperature profiles, were recorded and are reported here. The temperature profiles inside the enclosure were found to be dependent on the effective opening area A*, a combination of the upper and lower openings, and the ratio of buoyancy fluxes from the distributed and localised source Ψ =Bw/Bp . Industrial CASE award with ARUP.

  11. Scientific Benefit of Enlarging Gravitational Wave Detector Networks

    NASA Astrophysics Data System (ADS)

    Chu, Qi; Wen, Linqing; Blair, David

    2012-06-01

    Localising the sources of gravitational waves (GWs) in the sky is crucial to observing the electromagnetic counterparts of GW sources. The localisation capability is poor by a single GW detector yet can be improved by adding more detectors to the detector network. In this paper we review recent studies on scientific benefits of global detector networks and focus on their localisation capability. We employ Wen-Chen's formula to compare this merit of current and future detector networks for localising gravitational wave bursts. We find that the addition of a new detector located in Japan, or India, or Australia will increase angular resolution 3~5 fold with respect to current LIGO-Virgo network, and that the angular resolution improvement by adding a single detector in Australia is comparable to that achieved by adding detectors in both India and Japan. A six-site network achieves a 11-fold improvement in angular resolution compared with the existing three-site network.

  12. Interdependency of formation and localisation of the Min complex controls symmetric plastid division.

    PubMed

    Maple, Jodi; Møller, Simon G

    2007-10-01

    Plastid division represents a fundamental biological process essential for plant development; however, the molecular basis of symmetric plastid division is unclear. AtMinE1 plays a pivotal role in selection of the plastid division site in concert with AtMinD1. AtMinE1 localises to discrete foci in chloroplasts and interacts with AtMinD1, which shows a similar localisation pattern. Here, we investigate the importance of Min protein complex formation during the chloroplast division process. Dissection of the assembly of the Min protein complex and determination of the interdependency of complex assembly and localisation in planta allow us to present a model of the molecular basis of selection of the division site in plastids. Moreover, functional analysis of AtMinE1 in bacteria demonstrates the level of functional conservation and divergence of the plastidic MinE proteins.

  13. Kyste hydatique à localisation costo vertébrale

    PubMed Central

    Marouf, Rachid

    2014-01-01

    L'hydatidose est une affection parasitaire due à la contamination de l'homme par la forme larvaire de ténia échinococcus granulosus, la forme costo vertébrale est une localisation très rare qui représente 0,18 à 1,21% de l'ensemble des localisations hydatiques. Nous rapportons le cas d'une femme de 32 ans qui présente un kyste hydatique multi vésiculaire à localisation costovertébrale, traité par chirurgie radicale associée à un traitement médical anti parasitaire pour une durée de 6 mois, avec bonne évolution. L'atteinte costo-vertébrale par la maladie hydatique est rare et l’évolution est insidieuse. Malgré un traitement chirurgical radical, la fréquence des récidives rend le pronostic sombre. PMID:25922632

  14. Absolute High-Precision Localisation of an Unmanned Ground Vehicle by Using Real-Time Aerial Video Imagery for Geo-referenced Orthophoto Registration

    NASA Astrophysics Data System (ADS)

    Kuhnert, Lars; Ax, Markus; Langer, Matthias; Nguyen van, Duong; Kuhnert, Klaus-Dieter

    This paper describes an absolute localisation method for an unmanned ground vehicle (UGV) if GPS is unavailable for the vehicle. The basic idea is to combine an unmanned aerial vehicle (UAV) to the ground vehicle and use it as an external sensor platform to achieve an absolute localisation of the robotic team. Beside the discussion of the rather naive method directly using the GPS position of the aerial robot to deduce the ground robot's position the main focus of this paper lies on the indirect usage of the telemetry data of the aerial robot combined with live video images of an onboard camera to realise a registration of local video images with apriori registered orthophotos. This yields to a precise driftless absolute localisation of the unmanned ground vehicle. Experiments with our robotic team (AMOR and PSYCHE) successfully verify this approach.

  15. bicoid mRNA localises to the Drosophila oocyte anterior by random Dynein-mediated transport and anchoring

    PubMed Central

    Trovisco, Vítor; Belaya, Katsiaryna; Nashchekin, Dmitry; Irion, Uwe; Sirinakis, George; Butler, Richard; Lee, Jack J; Gavis, Elizabeth R; St Johnston, Daniel

    2016-01-01

    bicoid mRNA localises to the Drosophila oocyte anterior from stage 9 of oogenesis onwards to provide a local source for Bicoid protein for embryonic patterning. Live imaging at stage 9 reveals that bicoid mRNA particles undergo rapid Dynein-dependent movements near the oocyte anterior, but with no directional bias. Furthermore, bicoid mRNA localises normally in shot2A2, which abolishes the polarised microtubule organisation. FRAP and photo-conversion experiments demonstrate that the RNA is stably anchored at the anterior, independently of microtubules. Thus, bicoid mRNA is localised by random active transport and anterior anchoring. Super-resolution imaging reveals that bicoid mRNA forms 110–120 nm particles with variable RNA content, but constant size. These particles appear to be well-defined structures that package the RNA for transport and anchoring. DOI: http://dx.doi.org/10.7554/eLife.17537.001 PMID:27791980

  16. No wire? No problem: Resuscitative endovascular balloon occlusion of the aorta (REBOA) can be performed effectively and more rapidly with a wire-free device.

    PubMed

    Romagnoli, Anna Noel; Teeter, William; Wasicek, Philip; Gamble, William Bryan; Hu, Fu Peter M; Stein, Deborah; Scalea, Thomas; Brenner, Megan

    2018-06-12

    A wire-free device is available for REBOA providing aortic occlusion (AO) without lengthy platform guide-wires and large sheaths. This was a retrospective, single-institution review of patients who received REBOA from May 2014-September 2017. Timing of procedural steps was measured in seconds (s) using time-stamped videography. 74 patients received REBOA; 29 with a platform guidewire, 12F sheath, and balloon catheter (W group), and 45 with a 7F sheath and wire-free device (WF group). Mean age (p=0.22) and ISS (p=0.80) were similar between groups. 59 patients received REBOA at Zone 1; 15 patients at Zone 3. There was no difference in median [IQR] time to common femoral artery (CFA) access between the WF (194[98,313]s) and W (193[126,280]s) groups (p=0.96). Both median time to AO after CFA access (WF:158[109,264]s vs. W:307[222,390]s, p<0.001) and median total procedural time (WF:366[263,596]s vs. W:511[441,597]s; p=0.012) were significantly shorter with the wire-free system. The rates of percutaneous versus open CFA access was not different between groups (p=0.48). Both groups had a similar physiologic response to AO as measured by pre- and post-AO SBP (p=0.86). Overall mortality rate was 74%; 90% in the W group, and 64% in the WF group (p = 0.027). The procedure-related complication rate was not significantly different between groups with regard to compartment syndrome (W:3% vs WF:4%, p=1.0), access-related complications (W:0 vs WF:6%, p=0.28) or systemic complication (W:0 vs WF:9%, p=0.15). Once CFA access is obtained, AO with a smaller wire-free device reduces procedural time by approximately 50%. When perfusion to proximal organs is essential, the seconds saved to achieve AO may contribute to improved mortality. Time to obtain CFA access is not dependent on introducer sheath size. Therapeutic, Level V.

  17. Histopathology of Middle East respiratory syndrome coronovirus (MERS-CoV) infection - clinicopathological and ultrastructural study.

    PubMed

    Alsaad, Khaled O; Hajeer, Ali H; Al Balwi, Mohammed; Al Moaiqel, Mohammed; Al Oudah, Nourah; Al Ajlan, Abdulaziz; AlJohani, Sameera; Alsolamy, Sami; Gmati, Giamal E; Balkhy, Hanan; Al-Jahdali, Hamdan H; Baharoon, Salim A; Arabi, Yaseen M

    2018-02-01

    The pathogenesis, viral localization and histopathological features of Middle East respiratory syndrome - coronavirus (MERS-CoV) in humans are not described sufficiently. The aims of this study were to explore and define the spectrum of histological and ultrastructural pathological changes affecting various organs in a patient with MERS-CoV infection and represent a base of MERS-CoV histopathology. We analysed the post-mortem histopathological findings and investigated localisation of viral particles in the pulmonary and extrapulmonary tissue by transmission electron microscopic examination in a 33-year-old male patient of T cell lymphoma, who acquired MERS-CoV infection. Tissue needle biopsies were obtained from brain, heart, lung, liver, kidney and skeletal muscle. All samples were collected within 45 min from death to reduce tissue decomposition and artefact. Histopathological examination showed necrotising pneumonia, pulmonary diffuse alveolar damage, acute kidney injury, portal and lobular hepatitis and myositis with muscle atrophic changes. The brain and heart were histologically unremarkable. Ultrastructurally, viral particles were localised in the pneumocytes, pulmonary macrophages, renal proximal tubular epithelial cells and macrophages infiltrating the skeletal muscles. The results highlight the pulmonary and extrapulmonary pathological changes of MERS-CoV infection and provide the first evidence of the viral presence in human renal tissue, which suggests tissue trophism for MERS-CoV in kidney. © 2017 John Wiley & Sons Ltd.

  18. Bacillus anthracis TIR Domain-Containing Protein Localises to Cellular Microtubule Structures and Induces Autophagy.

    PubMed

    Carlsson, Emil; Thwaite, Joanne E; Jenner, Dominic C; Spear, Abigail M; Flick-Smith, Helen; Atkins, Helen S; Byrne, Bernadette; Ding, Jeak Ling

    2016-01-01

    Toll-like receptors (TLRs) recognise invading pathogens and mediate downstream immune signalling via Toll/IL-1 receptor (TIR) domains. TIR domain proteins (Tdps) have been identified in multiple pathogenic bacteria and have recently been implicated as negative regulators of host innate immune activation. A Tdp has been identified in Bacillus anthracis, the causative agent of anthrax. Here we present the first study of this protein, designated BaTdp. Recombinantly expressed and purified BaTdp TIR domain interacted with several human TIR domains, including that of the key TLR adaptor MyD88, although BaTdp expression in cultured HEK293 cells had no effect on TLR4- or TLR2- mediated immune activation. During expression in mammalian cells, BaTdp localised to microtubular networks and caused an increase in lipidated cytosolic microtubule-associated protein 1A/1B-light chain 3 (LC3), indicative of autophagosome formation. In vivo intra-nasal infection experiments in mice showed that a BaTdp knockout strain colonised host tissue faster with higher bacterial load within 4 days post-infection compared to the wild type B. anthracis. Taken together, these findings indicate that BaTdp does not play an immune suppressive role, but rather, its absence increases virulence. BaTdp present in wild type B. anthracis plausibly interact with the infected host cell, which undergoes autophagy in self-defence.

  19. Quantum State Diffusion

    NASA Astrophysics Data System (ADS)

    Percival, Ian

    2005-10-01

    1. Introduction; 2. Brownian motion and Itô calculus; 3. Open quantum systems; 4. Quantum state diffusion; 5. Localisation; 6. Numerical methods and examples; 7. Quantum foundations; 8. Primary state diffusion; 9. Classical dynamics of quantum localisation; 10. Semiclassical theory and linear dynamics.

  20. Contralateral routing of signals disrupts monaural level and spectral cues to sound localisation on the horizontal plane.

    PubMed

    Pedley, Adam J; Kitterick, Pádraig T

    2017-09-01

    Contra-lateral routing of signals (CROS) devices re-route sound between the deaf and hearing ears of unilaterally-deaf individuals. This rerouting would be expected to disrupt access to monaural level cues that can support monaural localisation in the horizontal plane. However, such a detrimental effect has not been confirmed by clinical studies of CROS use. The present study aimed to exercise strict experimental control over the availability of monaural cues to localisation in the horizontal plane and the fitting of the CROS device to assess whether signal routing can impair the ability to locate sources of sound and, if so, whether CROS selectively disrupts monaural level or spectral cues to horizontal location, or both. Unilateral deafness and CROS device use were simulated in twelve normal hearing participants. Monaural recordings of broadband white noise presented from three spatial locations (-60°, 0°, and +60°) were made in the ear canal of a model listener using a probe microphone with and without a CROS device. The recordings were presented to participants via an insert earphone placed in their right ear. The recordings were processed to disrupt either monaural level or spectral cues to horizontal sound location by roving presentation level or the energy across adjacent frequency bands, respectively. Localisation ability was assessed using a three-alternative forced-choice spatial discrimination task. Participants localised above chance levels in all conditions. Spatial discrimination accuracy was poorer when participants only had access to monaural spectral cues compared to when monaural level cues were available. CROS use impaired localisation significantly regardless of whether level or spectral cues were available. For both cues, signal re-routing had a detrimental effect on the ability to localise sounds originating from the side of the deaf ear (-60°). CROS use also impaired the ability to use level cues to localise sounds originating from straight ahead (0°). The re-routing of sounds can restrict access to the monaural cues that provide a basis for determining sound location in the horizontal plane. Perhaps encouragingly, the results suggest that both monaural level and spectral cues may not be disrupted entirely by signal re-routing and that it may still be possible to reliably identify sounds originating on the hearing side. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  1. Comparison of Flow Impairment during Carotid Artery Stenting Using Two Types of Eccentric Filter Embolic Protection Devices.

    PubMed

    Nii, Kouhei; Tsutsumi, Masanori; Maeda, Hitoshi; Aikawa, Hiroshi; Inoue, Ritsuro; Eto, Ayumu; Sakamoto, Kimiya; Mitsutake, Takafumi; Hanada, Hayatsura; Kazekawa, Kiyoshi

    2016-12-15

    We investigated the angiographic findings and the clinical outcomes after carotid artery stenting (CAS) using two different, eccentric filter embolic protection devices (EPDs). Between July 2010 and August 2015, 175 CAS procedures were performed using a self-expandable closed-cell stent and a simple eccentric filter EPD (FilterWire EZ in 86 and Spider FX in 89 procedures). The angiographic findings (i.e., flow impairment and vasospasm) at the level of EPDs, neurologic events, and post-operative imaging results were compared between the FilterWire EZ and the Spider FX groups. The CAS was angiographically successful in all 175 procedures. However, the angiographs were obtained immediately after CAS-detected flow impairment in the distal internal carotid artery (ICA) in 11 (6.3%) and ICA spasms at the level of the EPD in 40 cases (22.9%). The incidence of these complications was higher with FilterWire EZ than Spider FX (ICA flow impairment of 10.5% vs. 2.2%, P = 0.03; vasospasm 30.2% vs. 15.7%, P = 0.03). There were nine neurologic events (5.1%); five patients were presented with transient ischemic attacks, three had minor strokes, and one had a major stroke. New MRI lesions were seen in 25 (29.1%) FilterWire-group and in 36 (40.4%) Spider-group patients. The neurologic events and new MRI lesions were not associated with the type of EPD used. Although the ICA flow impairment may result in neurologic events, there was no significant association between the FilterWire EZ and the Spider FX CAS with respect to the incidence of neurologic events by the prompt treatment such as catheter aspiration.

  2. Debris extrusion and foraminal deformation produced by reciprocating instruments made of thermally treated NiTi wires

    PubMed Central

    Frota, Myrna Maria Arcanjo; Bernardes, Ricardo Affonso; Vivan, Rodrigo Ricci; Vivacqua-Gomes, Nilton; Duarte, Marco Antonio Hungaro; de Vasconcelos, Bruno Carvalho

    2018-01-01

    Abstract Objective To evaluate the amount of apically extruded debris, percentage of foraminal enlargement and apical foramen (AF) deformation that occurred during root canal preparation with different reciprocation systems: Reciproc, WaveOne (M-Wire), and ProDesign R (Shape Memory Technology Wire) at two different working lengths (WLs): 0.0 and 1.0 mm beyond the AF. Material and methods The AF of 120 root canals in 60 mesial roots of mandibular molars were photographed with stereomicroscope and randomly assigned into four groups: manual, Reciproc (REC), WaveOne (WO), and ProDesign R (PDR); subsequently, they were further subdivided according to the WL (n=15). Teeth were instrumented, coupled to a dual collecting chamber, and then another photograph of each AF was captured. Extrusion was analysed by determining the weight of extruded debris. Each AF diameter was measured in pre- and post-instrumentation images to determine deformation, which was analysed, and afterwards the final format of AFs was classified (circular/oval/deformed). Results We found no significant differences when analysing each system at different WLs. When considering each WL, REC and WO showed highest extrusion values (P<.05); for AF enlargement, differences were observed only for WO, when it was used beyond the AF; differences were observed among M-Wire groups beyond the AF (P<.05). AF deformation was observed in all groups; PDR showed the lowest AF deformation values at both WLs; M-Wire groups showed 50% strain beyond the AF. Conclusion Authors concluded that beyond the apical limit, the alloy and taper are important aspects when considering extrusion and deformation. PMID:29364346

  3. Accuracy of four different digital intraoral scanners: effects of the presence of orthodontic brackets and wire.

    PubMed

    Jung, Yoo-Ran; Park, Ji-Man; Chun, Youn-Sic; Lee, Kkot-Nim; Kim, Minji

    The objective of this study was to compare the accuracy of four different digital intraoral scanners and the effects of buccal brackets and orthodontic wire. For this study, three sets of models (Control model, BKT model with buccal bracket, and WBKT model with buccal bracket and orthodontic wire) were scanned using four different types of intraoral scanners: E4D dentist, iTero, Trios, and Zfx IntraScan. The mesiodistal width of the teeth, intercanine width, and intermolar width measured by four scanners were compared. Three-dimensional (3D) images of the brackets were taken using the four scanners. Data were analyzed with one-way ANOVA, independent t test, and post-hoc Tukey test at a significance level of P < 0.05. When comparing the 3D images with manual measurements using a traditional caliper, iTero and Trios showed the highest accuracy in horizontal measurements.iTero had the lowest values in Devmax-min of maxillary intermolar and intercanine widths (0.16 mm and 0.20 mm, respectively), whereas Trios had the lowest values in Devmax-min of mandibular intermolar and intercanine widths (0.36 mm and 0.14 mm, respectively). The horizontal variables were barely affected by the presence of buccal brackets and orthodontic wire. Comparison of 3D bracket images scanned by the four scanners showed differences in image distortion among the scanners. Bracket characteristics did not affect the 3D bracket images. The four intraoral scanners used in this study differed in accuracy. However, the results acquired by iTero and Trios were more reliable. Effects of buccal brackets and orthodontic wire on the 3D images taken by intraoral scanners were not clinically significant.

  4. Two-year survival analysis of twisted wire fixed retainer versus spiral wire and fiber-reinforced composite retainers: a preliminary explorative single-blind randomized clinical trial.

    PubMed

    Sobouti, Farhad; Rakhshan, Vahid; Saravi, Mahdi Gholamrezaei; Zamanian, Ali; Shariati, Mahsa

    2016-03-01

    Traditional retainers (both metal and fiber-reinforced composite [FRC]) have limitations, and a retainer made from more flexible ligature wires might be advantageous. We aimed to compare an experimental design with two traditional retainers. In this prospective preliminary clinical trial, 150 post-treatment patients were enrolled and randomly divided into three groups of 50 patients each to receive mandibular canine-to-canine retainers made of FRC, flexible spiral wire (FSW), and twisted wire (TW). The patients were monitored monthly. The time at which the first signs of breakage/debonding were detected was recorded. The success rates of the retainers were compared using chi-squared, Kaplan-Meier, and Cox proportional-hazard regression analyses (α = 0.05). In total, 42 patients in the FRC group, 41 in the FSW group, and 45 in the TW group completed the study. The 2-year failure rates were 35.7% in the FRC group, 26.8% in the FSW group, and 17.8% in the TW group. These rates differed insignificantly (chi-squared p = 0.167). According to the Kaplan-Meier analysis, failure occurred at 19.95 months in the FRC group, 21.37 months in the FSW group, and 22.36 months in the TW group. The differences between the survival rates in the three groups were not significant (Cox regression p = 0.146). Although the failure rate of the experimental retainer was two times lower than that of the FRC retainer, the difference was not statistically significant. The experimental TW retainer was successful, and larger studies are warranted to verify these results.

  5. Two-year survival analysis of twisted wire fixed retainer versus spiral wire and fiber-reinforced composite retainers: a preliminary explorative single-blind randomized clinical trial

    PubMed Central

    Sobouti, Farhad; Rakhshan, Vahid; Saravi, Mahdi Gholamrezaei; Zamanian, Ali

    2016-01-01

    Objective Traditional retainers (both metal and fiber-reinforced composite [FRC]) have limitations, and a retainer made from more flexible ligature wires might be advantageous. We aimed to compare an experimental design with two traditional retainers. Methods In this prospective preliminary clinical trial, 150 post-treatment patients were enrolled and randomly divided into three groups of 50 patients each to receive mandibular canine-to-canine retainers made of FRC, flexible spiral wire (FSW), and twisted wire (TW). The patients were monitored monthly. The time at which the first signs of breakage/debonding were detected was recorded. The success rates of the retainers were compared using chi-squared, Kaplan-Meier, and Cox proportional-hazard regression analyses (α = 0.05). Results In total, 42 patients in the FRC group, 41 in the FSW group, and 45 in the TW group completed the study. The 2-year failure rates were 35.7% in the FRC group, 26.8% in the FSW group, and 17.8% in the TW group. These rates differed insignificantly (chi-squared p = 0.167). According to the Kaplan-Meier analysis, failure occurred at 19.95 months in the FRC group, 21.37 months in the FSW group, and 22.36 months in the TW group. The differences between the survival rates in the three groups were not significant (Cox regression p = 0.146). Conclusions Although the failure rate of the experimental retainer was two times lower than that of the FRC retainer, the difference was not statistically significant. The experimental TW retainer was successful, and larger studies are warranted to verify these results. PMID:27019825

  6. Prostate cancer - evidence of exercise and nutrition trial (PrEvENT): study protocol for a randomised controlled feasibility trial.

    PubMed

    Hackshaw-McGeagh, Lucy; Lane, J Athene; Persad, Raj; Gillatt, David; Holly, Jeff M P; Koupparis, Anthony; Rowe, Edward; Johnston, Lyndsey; Cloete, Jenny; Shiridzinomwa, Constance; Abrams, Paul; Penfold, Chris M; Bahl, Amit; Oxley, Jon; Perks, Claire M; Martin, Richard

    2016-03-07

    A growing body of observational evidence suggests that nutritional and physical activity interventions are associated with beneficial outcomes for men with prostate cancer, including brisk walking, lycopene intake, increased fruit and vegetable intake and reduced dairy consumption. However, randomised controlled trial data are limited. The 'Prostate Cancer: Evidence of Exercise and Nutrition Trial' investigates the feasibility of recruiting and randomising men diagnosed with localised prostate cancer and eligible for radical prostatectomy to interventions that modify nutrition and physical activity. The primary outcomes are randomisation rates and adherence to the interventions at 6 months following randomisation. The secondary outcomes are intervention tolerability, trial retention, change in prostate specific antigen level, change in diet, change in general physical activity levels, insulin-like growth factor levels, and a range of related outcomes, including quality of life measures. The trial is factorial, randomising men to both a physical activity (brisk walking or control) and nutritional (lycopene supplementation or increased fruit and vegetables with reduced dairy consumption or control) intervention. The trial has two phases: men are enrolled into a cohort study prior to radical prostatectomy, and then consented after radical prostatectomy into a randomised controlled trial. Data are collected at four time points (cohort baseline, true trial baseline and 3 and 6 months post-randomisation). The Prostate Cancer: Evidence of Exercise and Nutrition Trial aims to determine whether men with localised prostate cancer who are scheduled for radical prostatectomy can be recruited into a cohort and subsequently randomised to a 6-month nutrition and physical activity intervention trial. If successful, this feasibility trial will inform a larger trial to investigate whether this population will gain clinical benefit from long-term nutritional and physical activity interventions post-surgery. Prostate Cancer: Evidence of Exercise and Nutrition Trial (PrEvENT) is registered on the ISRCTN registry, ref number ISRCTN99048944. Date of registration 17 November 2014.

  7. Geodynamic models of the Wilson Cycle: From rifts to mountains to rifts

    NASA Astrophysics Data System (ADS)

    Buiter, Susanne; Tetreault, Joya; Torsvik, Trond

    2015-04-01

    The Wilson Cycle theory that oceans close and reopen along the former suture is a fundamental concept in plate tectonics. The theory suggests that subduction initiates at a passive margin, closing the ocean, and that future continental extension localises at the ensuing collision zone. Each stage of the Wilson Cycle will therefore be characterised by inherited structural and thermal heterogeneities. Here we investigate the role of Wilson Cycle inheritance by considering the influence of (1) passive margin structure on continental collision and (2) collision zones on passive margin formation. Passive margins may be preferred locations for subduction initiation because inherited faults and areas of exhumed serpentinized mantle may weaken a margin enough to localise shortening. If subduction initiates at a passive margin, the shape and structure of the passive margins will affect future continental collision. Our review of present-day passive margins along the Atlantic and Indian Oceans reveals that most passive margins are located on former collision zones. Continental break-up occurs on relatively young sutures, such as Morocco-Nova Scotia, and on very old sutures, such as the Greenland-Labrador and East Antarctica-Australia systems. This implies that it is not always post-collisional collapse that initiates the extensional phase of a Wilson Cycle. We highlight the impact of collision zone inheritance on continental extension and rifted margin architecture. We show numerical experiments of one Wilson Cycle of subduction, collision, and extension. Subduction initiates at a tapered passive margin. Closure of a 60 Ma ocean leads to continental collision and slab break-off, followed by some tens of kilometres of slab eduction. Mantle flow above the sinking detached slab enhances deformation in the rift area. The resulting rift exposes not only continental crust, but also subduction-related sediments and oceanic crust remnants. Renewed subduction in the post-collision phase is enabled by lithosphere delamination and slab rollback, leading to back-arc extension in a style similar to the Tyrrhenian Sea.

  8. Prostatic needle biopsies following primary high intensity focused ultrasound (HIFU) therapy for prostatic adenocarcinoma: histopathological features in tumour and non-tumour tissue.

    PubMed

    Ryan, Paul; Finelli, Antonio; Lawrentschuk, Nathan; Fleshner, Neil; Sweet, Joan; Cheung, Carol; van der Kwast, Theodorus; Evans, Andrew

    2012-08-01

    High intensity focused ultrasound (HIFU) is currently offered as primary treatment for patients with clinically localised prostate cancer. Data on histopathological features of post-treatment biopsies are limited. Pretreatment biopsies were identified in 45 men (age range 41-85) who received primary HIFU therapy. Post-HIFU biopsies were performed in 30 of these patients (67%) at mean 14.1 months (95% CI 11.7 to 16.5) follow-up, 22 due to rising PSA and eight as part of routine follow-up. Biopsies were examined for presence, distribution and extent of adenocarcinoma, Gleason scores, use of standard immunohistochemistry and ablative tissue changes were attributable to HIFU. In post-HIFU biopsies performed for biochemical failure, 17/22 (77%) contained adenocarcinoma; 4/22 (18%) had higher post-HIFU Gleason score; 3/22 (14%) had newly recognised bilateral involvement; and 4/22 (18%) had higher percentage tissue involvement compared with pre-HIFU biopsies. Of cases without rising post-HIFU PSA, 2/8 (25%) routine follow-up biopsies contained adenocarcinoma. Stromal fibrosis was the commonest finding in non-tumour post-HIFU biopsy tissue (17/30, 57%) with coagulative necrosis occurring in fewer cases (4/30, 13%) and over a shorter follow-up interval than cases showing fibrosis (8.5 (0.2-16.8) vs 15.3 (11.5-19.1) months). Treatment effects in tumour cells precluding the assignment of Gleason scores or use of immunohistochemistry in post-HIFU biopsies were not identified. Post-HIFU biopsies are positive in more than 75% of patients with elevated or rising PSA. Stromal fibrosis is common but the tissue effects of this modality do not appear to impair pathologists' ability to detect and grade adenocarcinoma in follow-up biopsies.

  9. Is the HAS-BLED score useful in predicting post-extraction bleeding in patients taking warfarin? A retrospective cohort study

    PubMed Central

    Kataoka, Toshiyuki; Hoshi, Keika; Ando, Tomohiro

    2016-01-01

    Objective Unexpected post-extraction bleeding is often experienced in clinical practice. Therefore, determining the risk of post-extraction bleeding in patients receiving anticoagulant therapy prior to surgery is beneficial. This study aimed to verify whether the HAS-BLED score was useful in predicting post-extraction bleeding in patients taking warfarin. Design Retrospective cohort study. Setting Department of Oral and Maxillofacial Surgery, Tokyo Women's Medical University. Participants Participants included 258 sequential cases (462 teeth) who had undergone tooth extraction between 1 January 2010 and 31 December 2012 while continuing warfarin therapy. Main outcome measure Post-extraction risk factors for bleeding. The following data were collected as the predicting variables for multivariate logistic analysis: the HAS-BLED score, extraction site, tooth type, stability of teeth, extraction procedure, prothrombin time-international normalised ratio value, platelet count and the use of concomitant antiplatelet agents. Results Post-extraction bleeding was noted in 21 (8.1%) of the 258 cases. Haemostasis was achieved with localised haemostatic procedures in all the cases of post-extraction bleeding. The HAS-BLED score was found to be insufficient in predicting post-extraction bleeding (area under the curve=0.548, p=0.867, multivariate analysis). The risk of post-extraction bleeding was approximately three times greater in patients taking concomitant oral antiplatelet agents (risk ratio=2.881, p=0.035, multivariate analysis). Conclusions The HAS-BLED score alone could not predict post-extraction bleeding. The concomitant use of oral antiplatelet agents was a risk factor for post-extraction bleeding. No episodes of post-extraction bleeding required more than local measures for haemostasis. However, because this was a retrospective study conducted at a single institution, large-scale prospective cohort studies, which include cases of outpatient tooth extraction, will be necessary in the future. PMID:26936909

  10. The multifunctional Staufen proteins: conserved roles from neurogenesis to synaptic plasticity

    PubMed Central

    Heraud-Farlow, Jacki E.; Kiebler, Michael A.

    2014-01-01

    Staufen (Stau) proteins belong to a family of RNA-binding proteins (RBPs) that are important for RNA localisation in many organisms. In this review we discuss recent findings on the conserved role played by Stau during both the early differentiation of neurons and in the synaptic plasticity of mature neurons. Recent molecular data suggest mechanisms for how Stau2 regulates mRNA localisation, mRNA stability, translation, and ribonucleoprotein (RNP) assembly. We offer a perspective on how this multifunctional RBP has been adopted to regulate mRNA localisation under several different cellular and developmental conditions. PMID:25012293

  11. Game of life on phyllosilicates: Gliders, oscillators and still life

    NASA Astrophysics Data System (ADS)

    Adamatzky, Andrew

    2013-10-01

    A phyllosilicate is a sheet of silicate tetrahedra bound by basal oxygens. A phyllosilicate automaton is a regular network of finite state machines - silicon nodes and oxygen nodes - which mimics structure of the phyllosilicate. A node takes states 0 and 1. Each node updates its state in discrete time depending on a sum of states of its three (silicon) or six (oxygen) neighbours. Phyllosilicate automata exhibit localisations attributed to Conway's Game of Life: gliders, oscillators, still lifes, and a glider gun. Configurations and behaviour of typical localisations, and interactions between the localisations are illustrated.

  12. Distributed estimation of sensors position in underwater wireless sensor network

    NASA Astrophysics Data System (ADS)

    Zandi, Rahman; Kamarei, Mahmoud; Amiri, Hadi

    2016-05-01

    In this paper, a localisation method for determining the position of fixed sensor nodes in an underwater wireless sensor network (UWSN) is introduced. In this simple and range-free scheme, the node localisation is achieved by utilising an autonomous underwater vehicle (AUV) that transverses through the network deployment area, and that periodically emits a message block via four directional acoustic beams. A message block contains the actual known AUV position as well as a directional dependent marker that allows a node to identify the respective transmit beam. The beams form a fixed angle with the AUV body. If a node passively receives message blocks, it could calculate the arithmetic mean of the coordinates existing in each messages sequence, to find coordinates at two different time instants via two different successive beams. The node position can be derived from the two computed positions of the AUV. The major advantage of the proposed localisation algorithm is that it is silent, which leads to energy efficiency for sensor nodes. The proposed method does not require any synchronisation among the nodes owing to being silent. Simulation results, using MATLAB, demonstrated that the proposed method had better performance than other similar AUV-based localisation methods in terms of the rates of well-localised sensor nodes and positional root mean square error.

  13. Health monitoring of prestressing tendons in post-tensioned concrete structures

    NASA Astrophysics Data System (ADS)

    Salamone, Salvatore; Bartoli, Ivan; Nucera, Claudio; Phillips, Robert; Lanza di Scalea, Francesco

    2011-04-01

    Currently 90% of bridges built in California are post-tensioned box-girder. In such structures the steel tendons are the main load-carrying components. The loss of prestress, as well as the presence of defects or the tendon breakage, can be catastrophic for the entire structure. Unfortunately, today there is no well-established method for the monitoring of prestressing (PS) tendons that can provide simultaneous information related to the presence of defects and the level of prestress in a continuous, real time manner. If such a monitoring system were available, considerable savings would be achieved in bridge maintenance since repairs would be implemented in a timely manner without traffic disruptions. This paper presents a health monitoring system for PS tendons in post-tensioned structures of interest to Caltrans. Such a system uses ultrasonic guided waves and embedded sensors to provide simultaneously and in real time, (a) measurements of the level of applied prestress, and (b) defect detection at early grow stages. The proposed PS measurement technique exploits the sensitivity of ultrasonic waves to the inter-wire contact developing in a multi-wire strand as a function of prestress level. In particular the nonlinear ultrasonic behavior of the tendon under changing levels of prestress is monitored by tracking higher-order harmonics at (nω) arising under a fundamental guided-wave excitation at (ω). Moreover this paper also present real-time damage detection and location in post-tensioned bridge joints using Acoustic Emission techniques. Experimental tests on large-scale single-tendon PT joint specimens, subjected to multiple load cycles, will be presented to validate the monitoring of PS loads (through nonlinear ultrasonic probing) and the monitoring of damage progression and location (through acoustic emission techniques). Issues and potential for the use of such techniques to monitor post-tensioned bridges in the field will be discussed.

  14. Long-term surveillance of zinc implant in murine artery: Surprisingly steady biocorrosion rate.

    PubMed

    Drelich, Adam J; Zhao, Shan; Guillory, Roger J; Drelich, Jaroslaw W; Goldman, Jeremy

    2017-08-01

    Metallic zinc implanted into the abdominal aorta of rats out to 6months has been demonstrated to degrade while avoiding responses commonly associated with the restenosis of vascular implants. However, major questions remain regarding whether a zinc implant would ultimately passivate through the production of stable corrosion products or via a cell mediated fibrous encapsulation process that prevents the diffusion of critical reactants and products at the metal surface. Here, we have conducted clinically relevant long term in vivo studies in order to characterize late stage zinc implant biocorrosion behavior and products to address these critical questions. We found that zinc wires implanted in the murine artery exhibit steady corrosion without local toxicity for up to at least 20months post-implantation, despite a steady buildup of passivating corrosion products and intense fibrous encapsulation of the wire. Although fibrous encapsulation was not able to prevent continued implant corrosion, it may be related to the reduced chronic inflammation observed between 10 and 20months post-implantation. X-ray elemental and infrared spectroscopy analyses confirmed zinc oxide, zinc carbonate, and zinc phosphate as the main components of corrosion products surrounding the Zn implant. These products coincide with stable phases concluded from Pourbaix diagrams of a physiological solution and in vitro electrochemical impedance tests. The results support earlier predictions that zinc stents could become successfully bio-integrated into the arterial environment and safely degrade within a time frame of approximately 1-2years. Previous studies have shown zinc to be a promising candidate material for bioresorbable endovascular stenting applications. An outstanding question, however, is whether a zinc implant would ultimately passivate through the production of stable corrosion products or via a cell mediated tissue encapsulation process that prevented the diffusion of critical reactants and products at the metal surface. We found that zinc wires implanted in the murine artery exhibit steady corrosion for up to at least 20months post-implantation. The results confirm earlier predictions that zinc stents could safely degrade within a time frame of approximately 1-2years. Copyright © 2017 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  15. Congenital tuberculosis localised to the ear.

    PubMed Central

    Naranbhai, R C; Mathiassen, W; Malan, A F

    1989-01-01

    We report two infants who had localised congenital tuberculous otitis. In both cases the infants presented with an ear discharge and both mothers had been diagnosed as having miliary tuberculosis. Infection is thought to have occurred in utero or during birth. Images Figure PMID:2786383

  16. Cylindrical Asymmetrical Capacitor Devices for Space Applications

    NASA Technical Reports Server (NTRS)

    Campbell, Jonathan W. (Inventor)

    2004-01-01

    An asymmetrical capacitor system is provided which creates a thrust force. The system is adapted for use in space applications and includes a capacitor device provided with a first conductive element and a second conductive element axially spaced from the first conductive element and of smaller axial extent. A shroud supplied with gas surrounds the capacitor device. The second conductive element can be a wire ring or mesh mounted on dielectric support posts affixed to a dielectric member which separates the conductive elements or a wire or mesh annulus surrounding a barrel-shaped dielectric member on which the h t element is also mounted. A high voltage source is connected across the conductive elements and applies a high voltage to the conductive elements of sufficient value to create a thrust force on the system inducing movement thereof.

  17. Combined Volar Hamate Dislocation and Scapholunate Ligament Rupture: A Case Report.

    PubMed

    Walmsley, David; Dhotar, Herman; Geddes, Christopher; Axelrod, Terry

    2015-04-22

    A twenty-two-year-old male patient presented to our trauma center after a motor-vehicle accident in which he sustained multiple injuries, including a volar dislocation of the hamate and ipsilateral scapholunate dissociation. Following closed reduction of the hamate dislocation, open reduction and stabilization of these carpal injuries was undertaken two days post-injury via a dorsal approach. Percutaneous Kirschner wires were used as well as two mini suture anchors to repair the scapholunate ligament. The patient was immobilized for six weeks and Kirschner wires were removed at twelve weeks postoperatively. To our knowledge, hamate dislocation with scapholunate dissociation and its surgical treatment have not previously been described. Successful surgical treatment for this injury pattern may be performed dorsally via direct reduction and repair of the scapholunate ligament with percutaneous pinning of the affected carpal bones.

  18. A method for building low loss multi-layer wiring for superconducting microwave devices

    NASA Astrophysics Data System (ADS)

    Dunsworth, A.; Barends, R.; Chen, Yu; Chen, Zijun; Chiaro, B.; Fowler, A.; Foxen, B.; Jeffrey, E.; Kelly, J.; Klimov, P. V.; Lucero, E.; Mutus, J. Y.; Neeley, M.; Neill, C.; Quintana, C.; Roushan, P.; Sank, D.; Vainsencher, A.; Wenner, J.; White, T. C.; Neven, H.; Martinis, John M.; Megrant, A.

    2018-02-01

    Complex integrated circuits require multiple wiring layers. In complementary metal-oxide-semiconductor processing, these layers are robustly separated by amorphous dielectrics. These dielectrics would dominate energy loss in superconducting integrated circuits. Here, we describe a procedure that capitalizes on the structural benefits of inter-layer dielectrics during fabrication and mitigates the added loss. We use a deposited inter-layer dielectric throughout fabrication and then etch it away post-fabrication. This technique is compatible with foundry level processing and can be generalized to make many different forms of low-loss wiring. We use this technique to create freestanding aluminum vacuum gap crossovers (airbridges). We characterize the added capacitive loss of these airbridges by connecting ground planes over microwave frequency λ/4 coplanar waveguide resonators and measuring resonator loss. We measure a low power resonator loss of ˜3.9 × 10-8 per bridge, which is 100 times lower than that of dielectric supported bridges. We further characterize these airbridges as crossovers, control line jumpers, and as part of a coupling network in gmon and fluxmon qubits. We measure qubit characteristic lifetimes (T1s) in excess of 30 μs in gmon devices.

  19. Effect of hydrotherapy on the signs and symptoms of delayed onset muscle soreness.

    PubMed

    Vaile, Joanna; Halson, Shona; Gill, Nicholas; Dawson, Brian

    2008-03-01

    This study independently examined the effects of three hydrotherapy interventions on the physiological and functional symptoms of delayed onset muscle soreness (DOMS). Strength trained males (n = 38) completed two experimental trials separated by 8 months in a randomised crossover design; one trial involved passive recovery (PAS, control), the other a specific hydrotherapy protocol for 72 h post-exercise; either: (1) cold water immersion (CWI: n = 12), (2) hot water immersion (HWI: n = 11) or (3) contrast water therapy (CWT: n = 15). For each trial, subjects performed a DOMS-inducing leg press protocol followed by PAS or one of the hydrotherapy interventions for 14 min. Weighted squat jump, isometric squat, perceived pain, thigh girths and blood variables were measured prior to, immediately after, and at 24, 48 and 72 h post-exercise. Squat jump performance and isometric force recovery were significantly enhanced (P < 0.05) at 24, 48 and 72 h post-exercise following CWT and at 48 and 72 h post-exercise following CWI when compared to PAS. Isometric force recovery was also greater (P < 0.05) at 24, 48, and 72 h post-exercise following HWI when compared to PAS. Perceived pain improved (P < 0.01) following CWT at 24, 48 and 72 h post-exercise. Overall, CWI and CWT were found to be effective in reducing the physiological and functional deficits associated with DOMS, including improved recovery of isometric force and dynamic power and a reduction in localised oedema. While HWI was effective in the recovery of isometric force, it was ineffective for recovery of all other markers compared to PAS.

  20. A genome-wide resource for the analysis of protein localisation in Drosophila

    PubMed Central

    Sarov, Mihail; Barz, Christiane; Jambor, Helena; Hein, Marco Y; Schmied, Christopher; Suchold, Dana; Stender, Bettina; Janosch, Stephan; KJ, Vinay Vikas; Krishnan, RT; Krishnamoorthy, Aishwarya; Ferreira, Irene RS; Ejsmont, Radoslaw K; Finkl, Katja; Hasse, Susanne; Kämpfer, Philipp; Plewka, Nicole; Vinis, Elisabeth; Schloissnig, Siegfried; Knust, Elisabeth; Hartenstein, Volker; Mann, Matthias; Ramaswami, Mani; VijayRaghavan, K; Tomancak, Pavel; Schnorrer, Frank

    2016-01-01

    The Drosophila genome contains >13000 protein-coding genes, the majority of which remain poorly investigated. Important reasons include the lack of antibodies or reporter constructs to visualise these proteins. Here, we present a genome-wide fosmid library of 10000 GFP-tagged clones, comprising tagged genes and most of their regulatory information. For 880 tagged proteins, we created transgenic lines, and for a total of 207 lines, we assessed protein expression and localisation in ovaries, embryos, pupae or adults by stainings and live imaging approaches. Importantly, we visualised many proteins at endogenous expression levels and found a large fraction of them localising to subcellular compartments. By applying genetic complementation tests, we estimate that about two-thirds of the tagged proteins are functional. Moreover, these tagged proteins enable interaction proteomics from developing pupae and adult flies. Taken together, this resource will boost systematic analysis of protein expression and localisation in various cellular and developmental contexts. DOI: http://dx.doi.org/10.7554/eLife.12068.001 PMID:26896675

  1. La tuberculose extra-ganglionnaire primitive de la sphère ORL: à propos de 15 cas

    PubMed Central

    Touati, Mohamed Mliha; Darouassi, Youssef; Chihani, Mehdi; Lakouichmi, Mohammed; Tourabi, Khalid; Ammar, Haddou; Bouaity, Brahim

    2014-01-01

    Les localisations ORL extra ganglionnaires de la tuberculose sont rares. La symptomatologie clinique ainsi que les examens paracliniques sont souvent trompeurs,posant ainsi le problème de diagnostic différentiel avec la pathologie tumorale. Nous rapportons 15 cas de localisations extra ganglionnaires de tuberculose, colligés au service ORL et CCF de l'Hopital Militaire Avicenne de Marrakech colligés entre 2009 et 2013. L’âge moyen de nos patients est de 33 ans. L’étude topographique a montré 6 cas au niveau du cavum, un cas de miliaire tuberculeuse pharyngée, 4 cas laryngés; 2 localisations auriculaires; 1 parotidienne et 1 localisation sous maxillaire. Le diagnostic était anatomopathologiquedans tous les cas. Tous nos patients ont reçu un traitement antituberculeux avec une bonne évolution. Mots-clés: Tuberculose, amygdale, rhinopharynx, larynx, glandes salivaires,Oreille moyenne. PMID:25815100

  2. Correlative and integrated light and electron microscopy of in-resin GFP fluorescence, used to localise diacylglycerol in mammalian cells

    PubMed Central

    Peddie, Christopher J.; Blight, Ken; Wilson, Emma; Melia, Charlotte; Marrison, Jo; Carzaniga, Raffaella; Domart, Marie-Charlotte; O׳Toole, Peter; Larijani, Banafshe; Collinson, Lucy M.

    2014-01-01

    Fluorescence microscopy of GFP-tagged proteins is a fundamental tool in cell biology, but without seeing the structure of the surrounding cellular space, functional information can be lost. Here we present a protocol that preserves GFP and mCherry fluorescence in mammalian cells embedded in resin with electron contrast to reveal cellular ultrastructure. Ultrathin in-resin fluorescence (IRF) sections were imaged simultaneously for fluorescence and electron signals in an integrated light and scanning electron microscope. We show, for the first time, that GFP is stable and active in resin sections in vacuo. We applied our protocol to study the subcellular localisation of diacylglycerol (DAG), a modulator of membrane morphology and membrane dynamics in nuclear envelope assembly. We show that DAG is localised to the nuclear envelope, nucleoplasmic reticulum and curved tips of the Golgi apparatus. With these developments, we demonstrate that integrated imaging is maturing into a powerful tool for accurate molecular localisation to structure. PMID:24637200

  3. Null stream analysis of Pulsar Timing Array data: localisation of resolvable gravitational wave sources

    NASA Astrophysics Data System (ADS)

    Goldstein, Janna; Veitch, John; Sesana, Alberto; Vecchio, Alberto

    2018-04-01

    Super-massive black hole binaries are expected to produce a gravitational wave (GW) signal in the nano-Hertz frequency band which may be detected by pulsar timing arrays (PTAs) in the coming years. The signal is composed of both stochastic and individually resolvable components. Here we develop a generic Bayesian method for the analysis of resolvable sources based on the construction of `null-streams' which cancel the part of the signal held in common for each pulsar (the Earth-term). For an array of N pulsars there are N - 2 independent null-streams that cancel the GW signal from a particular sky location. This method is applied to the localisation of quasi-circular binaries undergoing adiabatic inspiral. We carry out a systematic investigation of the scaling of the localisation accuracy with signal strength and number of pulsars in the PTA. Additionally, we find that source sky localisation with the International PTA data release one is vastly superior than what is achieved by its constituent regional PTAs.

  4. Localised burst reconstruction from space-time PODs in a turbulent channel

    NASA Astrophysics Data System (ADS)

    Garcia-Gutierrez, Adrian; Jimenez, Javier

    2017-11-01

    The traditional proper orthogonal decomposition of the turbulent velocity fluctuations in a channel is extended to time under the assumption that the attractor is statistically stationary and can be treated as periodic for long-enough times. The objective is to extract space- and time-localised eddies that optimally represent the kinetic energy (and two-event correlation) of the flow. Using time-resolved data of a small-box simulation at Reτ = 1880 , minimal for y / h 0.25 , PODs are computed from the two-point spectral-density tensor Φ(kx ,kz , y ,y' , ω) . They are Fourier components in x, z and time, and depend on y and on the temporal frequency ω, or, equivalently, on the convection velocity c = ω /kx . Although the latter depends on y, a spatially and temporally localised `burst' can be synthesised by adding a range of PODs with specific phases. The results are localised bursts that are amplified and tilted, in a time-periodic version of Orr-like behaviour. Funded by the ERC COTURB project.

  5. The lung in amyloidosis.

    PubMed

    Milani, Paolo; Basset, Marco; Russo, Francesca; Foli, Andrea; Palladini, Giovanni; Merlini, Giampaolo

    2017-09-30

    Amyloidosis is a disorder caused by misfolding of autologous protein and its extracellular deposition as fibrils, resulting in vital organ dysfunction and eventually death. Pulmonary amyloidosis may be localised or part of systemic amyloidosis.Pulmonary interstitial amyloidosis is symptomatic only if the amyloid deposits severely affect gas exchange alveolar structure, thus resulting in serious respiratory impairment. Localised parenchymal involvement may be present as nodular amyloidosis or as amyloid deposits associated with localised lymphomas. Finally, tracheobronchial amyloidosis, which is usually not associated with evident clonal proliferation, may result in airway stenosis.Because the treatment options for amyloidosis are dependent on the fibril protein type, the workup of all new cases should include accurate determination of the amyloid protein. Most cases are asymptomatic and need only a careful follow-up. Diffuse alveolar-septal amyloidosis is treated according to the underlying systemic amyloidosis. Nodular pulmonary amyloidosis is usually localised, conservative excision is usually curative and the long-term prognosis is excellent. Tracheobronchial amyloidosis is usually treated with bronchoscopic interventions or external beam radiation therapy. Copyright ©ERS 2017.

  6. Experiments and Dynamic Finite Element Analysis of a Wire-Rope Rockfall Protective Fence

    NASA Astrophysics Data System (ADS)

    Tran, Phuc Van; Maegawa, Koji; Fukada, Saiji

    2013-09-01

    The imperative need to protect structures in mountainous areas against rockfall has led to the development of various protection methods. This study introduces a new type of rockfall protection fence made of posts, wire ropes, wire netting and energy absorbers. The performance of this rock fence was verified in both experiments and dynamic finite element analysis. In collision tests, a reinforced-concrete block rolled down a natural slope and struck the rock fence at the end of the slope. A specialized system of measuring instruments was employed to accurately measure the acceleration of the block without cable connection. In particular, the performance of two energy absorbers, which contribute also to preventing wire ropes from breaking, was investigated to determine the best energy absorber. In numerical simulation, a commercial finite element code having explicit dynamic capabilities was employed to create models of the two full-scale tests. To facilitate simulation, certain simplifying assumptions for mechanical data of each individual component of the rock fence and geometrical data of the model were adopted. Good agreement between numerical simulation and experimental data validated the numerical simulation. Furthermore, the results of numerical simulation helped highlight limitations of the testing method. The results of numerical simulation thus provide a deeper understanding of the structural behavior of individual components of the rock fence during rockfall impact. More importantly, numerical simulations can be used not only as supplements to or substitutes for full-scale tests but also in parametric study and design.

  7. Human dipeptidyl peptidase III acts as a post-proline-cleaving enzyme on endomorphins.

    PubMed

    Barsun, Marina; Jajcanin, Nina; Vukelić, Bojana; Spoljarić, Jasminka; Abramić, Marija

    2007-03-01

    Dipeptidyl peptidase III (DPP III) is a zinc exopeptidase with an implied role in the mammalian pain-modulatory system owing to its high affinity for enkephalins and localisation in the superficial laminae of the spinal cord dorsal horn. Our study revealed that this human enzyme hydrolyses opioid peptides belonging to three new groups, endomorphins, hemorphins and exorphins. The enzymatic hydrolysis products of endomorphin-1 were separated and quantified by capillary electrophoresis and the kinetic parameters were determined for human DPP III and rat DPP IV. Both peptidases cleave endomorphin-1 at comparable rates, with liberation of the N-terminal Tyr-Pro. This is the first evidence of DPP III acting as an endomorphin-cleaving enzyme.

  8. Characterisation of FAP-1 expression and CD95 mediated apoptosis in the A818-6 pancreatic adenocarcinoma differentiation system.

    PubMed

    Winterhoff, Boris J N; Arlt, Alexander; Duttmann, Angelika; Ungefroren, Hendrik; Schäfer, Heiner; Kalthoff, Holger; Kruse, Marie-Luise

    2012-03-01

    The present study investigated the expression and localisation of FAP-1 (Fas associated phosphatase-1) and CD95 in a 3D differentiation model in comparison to 2D monolayers of the pancreatic adenocarcinoma cell line A818-6. Under non-adherent growth conditions, A818-6 cells differentiate into 3D highly organised polarised epithelial hollow spheres, resembling duct-like structures. A818-6 cells showed a differentiation-dependent FAP-1 localisation. Cells grown as 2D monolayers revealed FAP-1 staining in a juxtanuclear cisternal position, as well as localisation in the nucleus. After differentiation into hollow spheres, FAP-1 was relocated towards the actin cytoskeleton beneath the outer plasma membrane of polarised cells and no further nuclear localisation was observed. CD95 surface staining was found only in a subset of A818-6 monolayer cells, while differentiated hollow spheres appeared to express CD95 in all cells of a given sphere. We rarely observed co-localisation of CD95 and FAP-1 in A818-6 monolayer cells, but strong co-localisation beneath the outer plasma membrane in polarised cells. Analysis of surface expression by flow cytometry revealed that only a subset (36%) of monolayer cells showed CD95 surface expression, and after induction of hollow spheres, CD95 presentation at the outer plasma membrane was reduced to 13% of hollow spheres. Induction of apoptosis by stimulation with agonistic anti-CD95 antibodies, resulted in increased caspase activity in both, monolayer cells and hollow spheres. Knock down of FAP-1 mRNA in A818-6 monolayer cells did not alter resposiveness to CD95 agonistic antibodies. These data suggested that CD95 signal transduction was not affected by FAP-1 expression in A818-6 monolayer cells. In differentiated 3D hollow spheres, we found a polarisation-induced co-localisation of CD95 and FAP-1. A tight control of receptor surface representation and signalling induced apoptosis ensures controlled removal of individual cells instead of a "snowball effect" of apoptotic events. Copyright © 2011 International Society of Differentiation. Published by Elsevier B.V. All rights reserved.

  9. The multifunctional Staufen proteins: conserved roles from neurogenesis to synaptic plasticity.

    PubMed

    Heraud-Farlow, Jacki E; Kiebler, Michael A

    2014-09-01

    Staufen (Stau) proteins belong to a family of RNA-binding proteins (RBPs) that are important for RNA localisation in many organisms. In this review we discuss recent findings on the conserved role played by Stau during both the early differentiation of neurons and in the synaptic plasticity of mature neurons. Recent molecular data suggest mechanisms for how Stau2 regulates mRNA localisation, mRNA stability, translation, and ribonucleoprotein (RNP) assembly. We offer a perspective on how this multifunctional RBP has been adopted to regulate mRNA localisation under several different cellular and developmental conditions. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    You, Jae-Hwan; Reed, Mark L.; Hiscox, Julian A.

    The severe acute respiratory syndrome-coronavirus nucleocapsid (N) protein is involved in virus replication and modulation of cell processes. In this latter respect control may in part be achieved through the sub-cellular localisation of the protein. N protein predominately localises in the cytoplasm (the site of virus replication and assembly) but also in the nucleus/nucleolus. Using a combination of live-cell and confocal microscopy coupled to mutagenesis we identified a cryptic nucleolar localisation signal in the central part of the N protein. In addition, based on structural comparison to the avian coronavirus N protein, a nuclear export signal was identified in themore » C-terminal region of the protein.« less

  11. Localised sarcoptic mange in dogs: a retrospective study of 10 cases.

    PubMed

    Pin, D; Bensignor, E; Carlotti, D-N; Cadiergues, M C

    2006-10-01

    The authors report 10 cases of localised sarcoptic mange in dogs. In each case, lesions were localised to one precise area of the skin. Pruritus was present in nine cases and absent in one. Affected areas were the feet (one case), the face and/or the pinnae (six cases), the abdominal skin (one case), the flank (one case) and the lumbar area (one case). The types of lesions were erythema, papules, lichenification, scales, crusts and alopecia. Parasites were found in all cases except one, in which anti-immunoglobulin G Sarcoptes serology was positive. The acaricidal treatments given were lindane, ivermectin or selamectin and were all successful.

  12. The Future of Digital Working: Knowledge Migration and Learning

    ERIC Educational Resources Information Center

    Malcolm, Irene

    2014-01-01

    Against the backdrop of intensified migration linked to globalisation, this article considers the implications of knowledge migration for future digital workers. It draws empirically on a socio-material analysis of the international software localisation industry. Localisers' work requires linguistic, cultural and software engineering skills to…

  13. Ex vivo kinematic studies of a canine unlinked semi-constrained hybrid total elbow arthroplasty system.

    PubMed

    Lorenz, N D; Channon, S; Pettitt, R; Smirthwaite, P; Innes, J F

    2015-01-01

    Introduction of the Sirius® canine total elbow arthroplasty system, and presentation of the results of a passive range-of-motion analysis based on ex vivo kinematic studies pre-and post-implantation. Thoracic limbs (n = 4) of medium sized dogs were harvested by forequarter amputation. Plain orthogonal radiographs of each limb were obtained pre- and post-implantation. Limbs were prepared by placement of external fixator pins and Kirschner wires into the humerus and radius. Each limb was secured into a custom-made box frame and retro-reflective markers were placed on the exposed ends of the pins and wires. Each elbow was manually moved through five ranges-of-motion manoeuvres. Data collected included six trials of i) full extension to full flexion and ii) pronation and supination in 90° flexion; a three-dimensional motion capture system was used to collect and analyse the data. The Sirius elbow prosthesis was subsequently implanted and the same measurements were repeated. Data sets were tested for normality. Paired t-tests were used for comparison of pre- and post-implantation motion parameters. Kinematic analysis showed that the range-of-motion (mean and SD) for flexion and extension pre-implantation was 115° ± 6 (range: 25° to 140°). The range-of-motion in the sagittal plane post-implantation was 90° ± 4 (range: 36° to 130°) and this reduction was significant (p = 0.0001). The ranges-of-motion (mean and SD) for supination and pronation at 90° were 50° ± 5, whereas the corresponding mean ranges-of-motion post-implantation were 38° ± 6 (p = 0.0188). Compared to a normal elbow, the range-of-motion was reduced. Post-implantation, supination and pronation range-of-motion was significantly reduced at 90° over pre-implantation values. These results provide valuable information regarding the effect of the Sirius system on ex vivo kinematics of the normal canine elbow joint. Further, this particular ex vivo model allowed for satisfactory and repeatable kinematic analysis.

  14. IRSp53 is colocalised with WAVE2 at the tips of protruding lamellipodia and filopodia independently of Mena.

    PubMed

    Nakagawa, Hiroyuki; Miki, Hiroaki; Nozumi, Motohiro; Takenawa, Tadaomi; Miyamoto, Shigeaki; Wehland, Jürgen; Small, J Victor

    2003-06-15

    The insulin receptor tyrosine kinase substrate p53 (IRSp53) links Rac and WAVE2 and has been implicated in lamellipodia protrusion. Recently, however, IRSp53 has been reported to bind to both Cdc42 and Mena to induce filopodia. To shed independent light on IRSp53 function we determined the localisations and dynamics of IRSp53 and WAVE2 in B16 melanoma cells. In cells spread well on a laminin substrate, IRSp53 was localised by antibody labelling at the tips of both lamellipodia and filopodia. The same localisation was observed in living cells with IRSp53 tagged with enhanced green florescence protein (EGFP-IRSp53), but only during protrusion. From the transfection of deletion mutants the N-terminal region of IRSp53, which binds active Rac, was shown to be responsible for its localisation. Although IRSp53 has been reported to regulate filopodia formation with Mena, EGFP-IRSp53 showed the same localisation in MVD7 Ena/VASP (vasodilator stimulated phosphoprotein) family deficient cells. WAVE2 tagged with DsRed1 colocalised with EGFP-IRSp53 at the tips of protruding lamellipodia and filopodia and, in double-transfected cells, the IRSp53 signal in filopodia decreased before that of WAVE2 during retraction. These results suggest an alternative modulatory role for IRSp53 in the extension of both filopodia and lamellipodia, through WAVE2.

  15. 14. Photographic copy of photograph, n.d. (original photograph in 55th ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    14. Photographic copy of photograph, n.d. (original photograph in 55th Wing Historian files, Offutt AFB, Bellevue, Nebraska). Detail of funnel-shaped drogue that holds the trailing wire antenna, a component of the aircraft's communication system. - Offutt Air Force Base, Looking Glass Airborne Command Post, Looking Glass Aircraft, On Operational Apron covering northeast half of Project Looking Glass Historic District, Bellevue, Sarpy County, NE

  16. Fe, Co, Ni: Electrical Resistivity Along their Melting Boundaries

    NASA Astrophysics Data System (ADS)

    Silber, R. E.; Ezenwa, I.; Secco, R.; Yong, W.

    2017-12-01

    Electrical resistivity of Fe, Co, and Ni was measured at pressures up to 11 GPa and temperatures into their liquid states in multi-anvil and cubic-anvil presses. Two thermocouples placed at opposite ends of the wire sample served as T probes as well as 4-wire resistance electrodes in a switched circuit. A polarity switch was also used to remove any bias associated with current flow and voltage measurement using thermocouple legs. Post experimental examination of recovered and sectioned samples was done using electron microprobe analyses to check for diffusion in our samples. The observed large jumps in resistivity at the high P melting T of each metal is consistent with its known P,T phase diagram and with post-run compositional analyses. The electrical resistivity behavior in these late transition metals as a function of increasing P and T shows expected trends consistent with 1atm data. Within the error of measurement, the resistivity values at the melting T at high P of Co and Ni appear to mimic their 1 atm value suggesting constant resistivity along the melting boundary. For liquid Fe, resistivity decreases along the melting boundary up to the triple point at 5.2 GPa, and then is nearly constant at higher pressures. The results are compared to prediction by Stacey and Loper (PEPI, 2007).

  17. Fibrin glue as agent for sealing corneal and conjunctival wound leaks.

    PubMed

    Scalcione, C; Ortiz-Vaquerizas, D; Said, D G; Dua, H S

    2018-02-01

    PurposeTo describe a novel use of fibrin glue in managing leaking blebs and leaking wounds following trauma or surgery.MethodsInterventional case series.ResultsWe report eight patients, including three where intra-operative or immediate post-penetrating keratoplasty recalcitrant leaks from the graft-host junction and/or openings created by the needle pass, were noted. All three had thin recipient beds in the sector of leak. This was managed by intra-cameral injection of fibrin glue in the affected quadrant. This stopped the leak and allowed the defect to heal. One patient of Descemets-stripping-endothelial-keratoplasty had leak from the surgical wound, which was also sealed with fibrin glue. Two patients with leaking glaucoma-surgery-related blebs were treated with intra-bleb injection of fibrin glue to stop the leak. One patient with a penetrating corneal injury with a metal wire had a brisk leak upon removal of the wire. This was sealed with fibrin glue. Another patient of chemical burn with spontaneous leaks was managed by glue injection in the perforations. Transient rise of intraocular pressure in one patient with a leaking bleb was the only adverse event recorded.ConclusionThis novel adaptation of the application of fibrin glue can help to deal with persistent intra-operative, post-operative and traumatic aqueous and air leaks.

  18. Moving with Modernisation and Civilisation: Taiwanese Nativist Education in the Early 1930s

    ERIC Educational Resources Information Center

    Huang, Hsuan-Yi

    2017-01-01

    This study examines localisation endeavours in contemporary Taiwan to explore the history of the Taiwanese localisation movement as a way of reimagining meanings of "Taiwaneseness" constructed under different historical circumstances. It focuses on the "xiangtu" (nativist) literature movement in colonial Taiwan in the early…

  19. Chinese Localisation of Evergreen: An Open Source Integrated Library System

    ERIC Educational Resources Information Center

    Zou, Qing; Liu, Guoying

    2009-01-01

    Purpose: The purpose of this paper is to investigate various issues related to Chinese language localisation in Evergreen, an open source integrated library system (ILS). Design/methodology/approach: A Simplified Chinese version of Evergreen was implemented and tested and various issues such as encoding, indexing, searching, and sorting…

  20. Utility of the balloon-overtube-assisted modified over-the-wire stenting technique to treat post-sleeve gastrectomy complications.

    PubMed

    Ponte, Ana; Pinho, Rolando; Proença, Luísa; Silva, Joana; Rodrigues, Jaime; Sousa, Mafalda; Silva, João Carlos; Carvalho, João

    2017-06-16

    To describe a modified technique of deployment of stents using the overtube developed for balloon-assisted enteroscopy in post-sleeve gastrectomy (SG) complications. Between January 2010 and December 2015, all patients submitted to an endoscopic stenting procedure to treat a post-SG stenosis or leakage were retrospectively collected. Procedures from patients in which the stent was deployed using the balloon-overtube-assisted modified over-the-wire (OTW) stenting technique were described. The technical success, corresponding to proper placement of the stent in the stomach resulting in exclusion of the SG leak or the stenosis, was evaluated. Complications related to stenting were also reported. Five procedures were included to treat 2 staple line leaks and 3 stenoses. Two types of stents were used, including a fully covered self-expandable metal stent designed for the SG anatomy (Hanarostent, ECBB-30-240-090; M.I. Tech, Co., Ltd, Seoul, South Korea) in 4 procedures and a biodegradable stent (BD stent 019-10A-25/20/25-080, SX-ELLA, Hradec Kralove, Czech Republic) in the remaining procedure. In all cases, an overtube was advanced with the endoscope through the SG to the duodenum. After placement of the guidewire and removal of the endoscope, the stent was easily advanced through the overtube. The overtube was pulled back and the stent was successfully deployed under fluoroscopic guidance. Technical success was achieved in all patients. The adoption of a modified technique of deployment of OTW stents using an overtube may represent an effective option in the approach of SG complications.

  1. Utility of the balloon-overtube-assisted modified over-the-wire stenting technique to treat post-sleeve gastrectomy complications

    PubMed Central

    Ponte, Ana; Pinho, Rolando; Proença, Luísa; Silva, Joana; Rodrigues, Jaime; Sousa, Mafalda; Silva, João Carlos; Carvalho, João

    2017-01-01

    AIM To describe a modified technique of deployment of stents using the overtube developed for balloon-assisted enteroscopy in post-sleeve gastrectomy (SG) complications. METHODS Between January 2010 and December 2015, all patients submitted to an endoscopic stenting procedure to treat a post-SG stenosis or leakage were retrospectively collected. Procedures from patients in which the stent was deployed using the balloon-overtube-assisted modified over-the-wire (OTW) stenting technique were described. The technical success, corresponding to proper placement of the stent in the stomach resulting in exclusion of the SG leak or the stenosis, was evaluated. Complications related to stenting were also reported. RESULTS Five procedures were included to treat 2 staple line leaks and 3 stenoses. Two types of stents were used, including a fully covered self-expandable metal stent designed for the SG anatomy (Hanarostent, ECBB-30-240-090; M.I. Tech, Co., Ltd, Seoul, South Korea) in 4 procedures and a biodegradable stent (BD stent 019-10A-25/20/25-080, SX-ELLA, Hradec Kralove, Czech Republic) in the remaining procedure. In all cases, an overtube was advanced with the endoscope through the SG to the duodenum. After placement of the guidewire and removal of the endoscope, the stent was easily advanced through the overtube. The overtube was pulled back and the stent was successfully deployed under fluoroscopic guidance. Technical success was achieved in all patients. CONCLUSION The adoption of a modified technique of deployment of OTW stents using an overtube may represent an effective option in the approach of SG complications. PMID:28690770

  2. The enhanced ASDEX Upgrade pellet centrifuge launcher

    NASA Astrophysics Data System (ADS)

    Plöckl, B.; Lang, P. T.

    2013-10-01

    Pellets played an important role in the program of ASDEX Upgrade serving both for investigations on efficient particle fuelling and high density scenarios but also for pioneering work on Edge Localised Mode (ELM) pacing and mitigation. Initially designed for launching fuelling pellets from the magnetic low field side, the system was converted already some time ago to inject pellets from the magnetic high field side as much higher fuelling efficiency was found using this configuration. In operation for more than 20 years, the pellet launching system had to undergo a major revision and upgrading, in particular of its control system. Furthermore, the control system installed adjacent to the launcher had to be transferred to a more distant location enforcing a complete galvanic separation from torus potential and a fully remote control solution. Changing from a hybrid system consisting of PLC S5/S7 and some hard wired relay control to a state of the art PLC system allowed the introduction of several new operational options enabling more flexibility in the pellet experiments. This article describes the new system architecture of control hardware and software, the operating procedure, and the extended operational window. First successful applications for ELM pacing and triggering studies are presented as well as utilization for the development of high density scenarios.

  3. A drift chamber tracking system for muon scattering tomography applications

    NASA Astrophysics Data System (ADS)

    Burns, J.; Quillin, S.; Stapleton, M.; Steer, C.; Snow, S.

    2015-10-01

    Muon scattering tomography (MST) allows the identification of shielded high atomic number (high-Z) materials by measuring the scattering angle of cosmic ray muons passing through an inspection region. Cosmic ray muons scatter to a greater degree due to multiple Coulomb scattering in high-Z materials than low-Z materials, which can be measured as the angular difference between the incoming and outgoing trajectories of each muon. Measurements of trajectory are achieved by placing position sensitive particle tracking detectors above and below the inspection volume. By localising scattering information, the point at which a series of muons scatter can be used to reconstruct an image, differentiating high, medium and low density objects. MST is particularly useful for differentiating between materials of varying density in volumes that are difficult to inspect visually or by other means. This paper will outline the experimental work undertaken to develop a prototype MST system based on drift chamber technology. The planar drift chambers used in this prototype measure the longitudinal interaction position of an ionising particle from the time taken for elections, liberated in the argon (92.5%), carbon dioxide (5%), methane (2.5%) gas mixture, to reach a central anode wire. Such a system could be used to enhance the detection of shielded radiological material hidden within regular shipping cargo.

  4. The enhanced ASDEX Upgrade pellet centrifuge launcher.

    PubMed

    Plöckl, B; Lang, P T

    2013-10-01

    Pellets played an important role in the program of ASDEX Upgrade serving both for investigations on efficient particle fuelling and high density scenarios but also for pioneering work on Edge Localised Mode (ELM) pacing and mitigation. Initially designed for launching fuelling pellets from the magnetic low field side, the system was converted already some time ago to inject pellets from the magnetic high field side as much higher fuelling efficiency was found using this configuration. In operation for more than 20 years, the pellet launching system had to undergo a major revision and upgrading, in particular of its control system. Furthermore, the control system installed adjacent to the launcher had to be transferred to a more distant location enforcing a complete galvanic separation from torus potential and a fully remote control solution. Changing from a hybrid system consisting of PLC S5/S7 and some hard wired relay control to a state of the art PLC system allowed the introduction of several new operational options enabling more flexibility in the pellet experiments. This article describes the new system architecture of control hardware and software, the operating procedure, and the extended operational window. First successful applications for ELM pacing and triggering studies are presented as well as utilization for the development of high density scenarios.

  5. The enhanced ASDEX Upgrade pellet centrifuge launcher

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Plöckl, B.; Lang, P. T.

    2013-10-15

    Pellets played an important role in the program of ASDEX Upgrade serving both for investigations on efficient particle fuelling and high density scenarios but also for pioneering work on Edge Localised Mode (ELM) pacing and mitigation. Initially designed for launching fuelling pellets from the magnetic low field side, the system was converted already some time ago to inject pellets from the magnetic high field side as much higher fuelling efficiency was found using this configuration. In operation for more than 20 years, the pellet launching system had to undergo a major revision and upgrading, in particular of its control system.more » Furthermore, the control system installed adjacent to the launcher had to be transferred to a more distant location enforcing a complete galvanic separation from torus potential and a fully remote control solution. Changing from a hybrid system consisting of PLC S5/S7 and some hard wired relay control to a state of the art PLC system allowed the introduction of several new operational options enabling more flexibility in the pellet experiments. This article describes the new system architecture of control hardware and software, the operating procedure, and the extended operational window. First successful applications for ELM pacing and triggering studies are presented as well as utilization for the development of high density scenarios.« less

  6. GPR applications for geotechnical stability of transportation infrastructures

    NASA Astrophysics Data System (ADS)

    Benedetto, A.; Benedetto, F.; Tosti, F.

    2012-09-01

    Nowadays, severe meteorological events are always more frequent all over the world. This causes a strong impact on the environment such as numerous landslides, especially in rural areas. Rural roads are exposed to an increased risk for geotechnical instability. In the meantime, financial resources for maintenance are certainly decreased due to the international crisis and other different domestic factors. In this context, the best allocation of funds becomes a priority: efficiency and effectiveness of plans and actions are crucially requested. For this purpose, the correct localisation of geotechnically instable domains is strategic. In this paper, the use of Ground-Penetrating Radar (GPR) for geotechnical inspection of pavement and sub-pavement layers is proposed. A three-step protocol has been calibrated and validated to allocate efficiently and effectively the maintenance funds. In the first step, the instability is localised through an inspection at traffic speed using a 1-GHz GPR horn launched antenna. The productivity is generally about or over 300 Km/day. Data are processed offline by automatic procedures. In the second step, a GPR inspection restricted to the critical road sections is carried out using two coupled antennas. One antenna is used for top pavement inspection (1.6 GHz central frequency) and a second antenna (600 MHz central frequency) is used for sub-pavement structure diagnosis. Finally, GPR data are post-processed in the time and frequency domains to identify accurately the geometry of the instability. The case study shows the potentiality of this protocol applied to the rural roads exposed to a landslide.

  7. Minimal hardware Bluetooth tracking for long-term at-home elder supervision.

    PubMed

    Kelly, Damian; McLoone, Sean; Farrell, Ronan

    2010-01-01

    The ability to automatically detect the location of an elder within their own home is a significant enabler of remote elder supervision and interaction applications. This location information is typically generated via a myriad of sensors throughout the home environment. Even with high sensor redundancy, there are still situations where traditional elder monitoring systems are unable to resolve the location of the elder. This work develops a minimal infrastructure radio-frequency localisation system for long-term elder location tracking. An RFID room-labelling technique is employed and with it, the localisation system developed in this work is shown to exhibit superior performance to more traditional localisation systems in realistic long-term deployments.

  8. [Extragenital endometriosis: Parietal, thoracic, diaphragmatic and nervous lesions. CNGOF-HAS Endometriosis Guidelines].

    PubMed

    Merlot, B; Ploteau, S; Abergel, A; Rubob, C; Hocke, C; Canis, M; Fritel, X; Roman, H; Collinet, P

    2018-03-01

    According to some studies, extragenital endometriosis represents 5% of the localisations. Its prevalence seems to be underestimated. The extra pelvic localisation can make the diagnosis more difficult. Nevertheless, the recurrent and catamenial symptomatology can evoke this pathology. Surgery seems to be the unique efficient treatment for parietal lesions. Pain linked to nervous lesions (peripheric and sacral roots) seems to be underestimated and difficult to diagnose because of various localisations. Neurolysis seems to have encouraging results. Diaphragmatic lesions are often discovered either incidentally during laparoscopy, or by pulmonary symptomatology as recurrent catamenial pneumothorax or cyclic thoracic pain. Surgical treatment seems as well to be efficient. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  9. Wire-positioning algorithm for coreless Hall array sensors in current measurement

    NASA Astrophysics Data System (ADS)

    Chen, Wenli; Zhang, Huaiqing; Chen, Lin; Gu, Shanyun

    2018-05-01

    This paper presents a scheme of circular-arrayed, coreless Hall-effect current transformers. It can satisfy the demands of wide dynamic range and bandwidth current in the distribution system, as well as the demand of AC and DC simultaneous measurements. In order to improve the signal to noise ratio (SNR) of the sensor, a wire-positioning algorithm is proposed, which can improve the measurement accuracy based on the post-processing of measurement data. The simulation results demonstrate that the maximum errors are 70%, 6.1% and 0.95% corresponding to Ampère’s circuital method, approximate positioning algorithm and precise positioning algorithm, respectively. It is obvious that the accuracy of the positioning algorithm is significantly improved when compared with that of the Ampère’s circuital method. The maximum error of the positioning algorithm is smaller in the experiment.

  10. Annealing effects on capacitance-voltage characteristics of a-Si/SiN(x) multilayer prepared using hot-wire chemical vapour deposition.

    PubMed

    Panchal, A K; Rai, D K; Solanki, C S

    2011-04-01

    Post-deposition annealing of a-Si/SiN(x) multilayer films at different temperature shows varying shift in high frequency (1 MHz) capacitance-voltage (HFCV) characteristics. Various a-Si/SiN(x) multilayer films were deposited using hot wire chemical vapor deposition (HWCVD) and annealed in the temperature range of 800 to 900 degrees C to precipitate Si quantum dots (Si-QD) in a-Si layers. HFCV measurements of the as-deposited and annealed films in metal-insulator-semiconductor (MIS) structures show hysterisis in C-V curves. The hysteresis in the as-deposited films and annealed films is attributed to charge trapping in Si-dangling bonds in a-Si layer and in Si-QD respectively. The charge trapping density in Si-QD increases with temperature while the interface defects density (D(it)) remains constant.

  11. On-wire lithography: synthesis, encoding and biological applications

    PubMed Central

    Banholzer, Matthew J; Qin, Lidong; Millstone, Jill E; Osberg, Kyle D; Mirkin, Chad A

    2014-01-01

    The next step in the maturing field of nanotechnology is to develop ways to introduce unusual architectural changes to simple building blocks. For nanowires, on-wire lithography (OWL) has emerged as a powerful way of synthesizing a segmented structure and subsequently introducing architectural changes through post-chemical treatment. In the OWL protocol presented here, multisegmented nanowires are grown and a support layer is deposited on one side of each nanostructure. After selective chemical etching of sacrificial segments, structures with gaps as small as 2 nm and disks as thin as 20 nm can be created. These nanostructures are highly tailorable and can be used in electrical transport, Raman enhancement and energy conversion. Such nanostructures can be functionalized with many types of adsorbates, enabling the use of OWL-generated structures as bioactive probes for diagnostic assays and molecular transport junctions. The process takes 13–36 h depending on the type of adsorbate used to functionalize the nanostructures. PMID:19444241

  12. Endotherapy for severe and complete pharyngo-esophageal post-radiation stenosis using wires, balloons and pharyngo-esophageal puncture (PEP) (with videos).

    PubMed

    Tang, Shou-jiang; Singh, Shailender; Truelson, John M

    2010-01-01

    Pharyngo-esophageal stenosis (PES) and upper esophageal stricture are common in patients who receive radiation therapy for laryngeal and hypopharyngeal cancers. In severe or complete stenosis, the patients generally have complete dysphagia with inability to swallow their saliva. Diagnostic and therapeutic esophagogastroduodenoscopy (EGD) plays an important role in investigating the dysphagia and in managing the underlying stenosis. We translate endoscopic retrograde cholangiopancreatography (ERCP) techniques and skills in approaching pancreaticobiliary obstruction in the management of severe and complete PES. We select and report three cases of severe or complete PES in which flexible endoscopic therapy was successfully provided by using fluoroscopy, ERCP wire guides, endoscopic balloons, and by performing pharyngo-esophageal puncture (PEP). We propose the term PEP in managing complete PES. We believe this approach can offer safety and efficiency with very high success rate.

  13. Fatal hemorrhage following sacroiliac joint fusion surgery: A case report.

    PubMed

    Palmiere, Cristian; Augsburger, Marc; Del Mar Lesta, Maria; Grabherr, Silke; Borens, Olivier

    2017-05-01

    Threaded pins and wires are commonly used in orthopedic practice and their migration intra- or post-operatively may be responsible for potentially serious complications. Vascular and visceral injury from intra-pelvic pin or guide-wire migration during or following hip surgery has been reported frequently in the literature and may result in progression through soft tissues with subsequent perforation of organs and vessels. In this report, we describe an autopsy case involving a 40-year old man suffering from chronic low back pain due to sacroiliac joint disruption. The patient underwent minimally invasive sacroiliac joint arthrodesis. Some intra-operative bleeding was noticed when a drill was retrieved, though the patient died postoperatively. Postmortem investigations allowed the source of bleeding to be identified (a perforation of a branch of the right internal iliac artery) and a potentially toxic tramadol concentration in peripheral blood to be measured. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  14. Influence of epoxy, polytetrafluoroethylene (PTFE) and rhodium surface coatings on surface roughness, nano-mechanical properties and biofilm adhesion of nickel titanium (Ni-Ti) archwires

    NASA Astrophysics Data System (ADS)

    Asiry, Moshabab A.; AlShahrani, Ibrahim; Almoammar, Salem; Durgesh, Bangalore H.; Kheraif, Abdulaziz A. Al; Hashem, Mohamed I.

    2018-02-01

    Aim. To investigate the effect of epoxy, polytetrafluoroethylene (PTFE) and rhodium surface coatings on surface roughness, nano-mechanical properties and biofilm adhesion of nickel titanium (Ni-Ti) archwires Methods. Three different coated (Epoxy, polytetrafluoroethylene (PTFE) and rhodium) and one uncoated Ni-Ti archwires were evaluated in the present study. Surface roughness (Ra) was assessed using a non-contact surface profilometer. The mechanical properties (nano-hardness and elastic modulus) were measured using a nanoindenter. Bacterial adhesion assays were performed using Streptococcus mutans (MS) and streptococcus sobrinus (SS) in an in-vitro set up. The data obtained were analyzed using analyses of variance, Tukey’s post hoc test and Pearson’s correlation coefficient test. Result. The highest Ra values (1.29 ± 0.49) were obtained for epoxy coated wires and lowest Ra values (0.29 ± 0.16) were obtained for the uncoated wires. No significant differences in the Ra values were observed between the rhodium coated and uncoated archwires (P > 0.05). The highest nano-hardness (3.72 ± 0.24) and elastic modulus values (61.15 ± 2.59) were obtained for uncoated archwires and the lowest nano-hardness (0.18 ± 0.10) and elastic modulus values (4.84 ± 0.65) were observed for epoxy coated archwires. No significant differences in nano-hardness and elastic modulus values were observed between the coated archwires (P > 0.05). The adhesion of Streptococcus mutans (MS) to the wires was significantly greater than that of streptococcus sobrinus (SS). The epoxy coated wires demonstrated an increased adhesion of MS and SS and the uncoated wires demonstrated decreased biofilm adhesion. The Spearman correlation test showed that MS and SS adhesion was positively correlated with the surface roughness of the wires. Conclusion. The different surface coatings significantly influence the roughness, nano-mechanical properties and biofilm adhesion parameters of the archwires. The evaluated parameters were most influenced by epoxy coating followed by PTFE and rhodium coating. A positive correlation was detected between surface roughness and biofilm adhesion.

  15. Live and let die--Arabidopsis nonhost resistance to powdery mildews.

    PubMed

    Lipka, Ulrike; Fuchs, Rene; Kuhns, Christine; Petutschnig, Elena; Lipka, Volker

    2010-01-01

    The term "nonhost resistance" (NHR) describes the phenomenon that an entire plant species is resistant to all genetic variants of a non-adapted pathogen species. In nature, NHR represents the most robust form of plant immunity and is therefore of scientific as well as economic importance. Due to its highly complex nature, NHR has previously not been studied in detail. Recently, the establishment of model interaction systems utilizing Arabidopsis and non-adapted powdery mildews allowed the identification of several key components and conceptual conclusions. It is now generally accepted that NHR of Arabidopsis to powdery mildews comprises two distinct layers of defence: pre-invasion entry control at the cell periphery and post-invasion resistance based on cell death execution. The timely production and localised discharge of toxic compounds at sites of fungal attack appear to be pivotal for entry control. This process requires proteins involved in secretion and trans-membrane transport, synthesis and activation of indolic glucosinolates as well as gene regulation and post-translational protein modification. Post-invasion defence relies on lipase-like proteins and salicylic acid signalling. To what extent pathogen-associated molecular pattern- or effector-triggered immunity contribute to NHR remains to be investigated and is likely to depend on the model system studied. Copyright 2009 Elsevier GmbH. All rights reserved.

  16. Nationalisation, Localisation and Globalisation in Finnish Higher Education

    ERIC Educational Resources Information Center

    Valimaa, Jussi

    2004-01-01

    This article analyses and discusses the interplay between the social processes of nationalisation, localisation and globalisation in a single European nation state. The view of nationalisation put forward draws on a national case study based on historical and sociological research findings. The second part of the article presents a case study of…

  17. Collaborations between Foreign-Invested Enterprises and China's VET Schools: Making the System Work amid Localised Skill Shortages

    ERIC Educational Resources Information Center

    Li, Yiqiong; Sheldon, Peter

    2014-01-01

    This article examines collaborative initiatives individual foreign-invested enterprises (FIEs) develop with China's vocational education and training (VET) schools amid localised shortages of skilled workers. It thus focuses on employer initiatives in responding to VET system weaknesses rather than, as is common, those weaknesses. Using Suzhou…

  18. Nuclear localisation of calreticulin in vivo is enhanced by its interaction with glucocorticoid receptors.

    PubMed

    Roderick, H L; Campbell, A K; Llewellyn, D H

    1997-03-24

    The multi-functional protein calreticulin (CRT) is normally found within the lumen of the endoplasmic reticulum (ER). However, some of its proposed functions require it to be located within the nucleus, where its presence is contentious. We have investigated this in live COS7, HeLa and LM(TK-) cells using green fluorescent protein (GFP)-fusion proteins. GFP-CRT, and GFP, with an ER signal peptide and a KDEL sequence (ER-GFP), were localised to the ER. In addition, GFP-CRT was located in the nucleus of all the cell types at low levels. The higher levels of nuclear fluorescence in LM(TK-) and HeLa cells suggested that glucocorticoid receptors might enhance nuclear localisation of calreticulin. Dexamethasone treatment of LM(TK-) cells doubled the amount of nuclear GFP-CRT, but did not affect the localisation of a GFP-CRT fusion in which the glucocorticoid receptor-binding N-domain of calreticulin had been deleted. Thus, despite ER targeting and retention signals, calreticulin is also located within the nucleus where its presence increases due to its interaction with glucocorticoid receptors.

  19. Connexin Communication Compartments and Wound Repair in Epithelial Tissue.

    PubMed

    Chanson, Marc; Watanabe, Masakatsu; O'Shaughnessy, Erin M; Zoso, Alice; Martin, Patricia E

    2018-05-03

    Epithelial tissues line the lumen of tracts and ducts connecting to the external environment. They are critical in forming an interface between the internal and external environment and, following assault from environmental factors and pathogens, they must rapidly repair to maintain cellular homeostasis. These tissue networks, that range from a single cell layer, such as in airway epithelium, to highly stratified and differentiated epithelial surfaces, such as the epidermis, are held together by a junctional nexus of proteins including adherens, tight and gap junctions, often forming unique and localised communication compartments activated for localised tissue repair. This review focuses on the dynamic changes that occur in connexins, the constituent proteins of the intercellular gap junction channel, during wound-healing processes and in localised inflammation, with an emphasis on the lung and skin. Current developments in targeting connexins as corrective therapies to improve wound closure and resolve localised inflammation are also discussed. Finally, we consider the emergence of the zebrafish as a concerted whole-animal model to study, visualise and track the events of wound repair and regeneration in real-time living model systems.

  20. Phosphorylation of Tat-interactive protein 60 kDa by protein kinase C epsilon is important for its subcellular localisation.

    PubMed

    Sapountzi, Vasileia; Logan, Ian R; Nelson, Glyn; Cook, Susan; Robson, Craig N

    2008-01-01

    Tat-interactive protein 60 kDa is a nuclear acetyltransferase that both coactivates and corepresses transcription factors and has a definitive function in the DNA damage response. Here, we provide evidence that Tat-interactive protein 60 kDa is phosphorylated by protein kinase C epsilon. In vitro, protein kinase C epsilon phosphorylates Tat-interactive protein 60 kDa on at least two sites within the acetyltransferase domain. In whole cells, activation of protein kinase C increases the levels of phosphorylated Tat-interactive protein 60 kDa and the interaction of Tat-interactive protein 60 kDa with protein kinase C epsilon. A phosphomimetic mutant Tat-interactive protein 60 kDa has distinct subcellular localisation compared to the wild-type protein in whole cells. Taken together, these findings suggest that the protein kinase C epsilon phosphorylation sites on Tat-interactive protein 60 kDa are important for its subcellular localisation. Regulation of the subcellular localisation of Tat-interactive protein 60 kDa via phosphorylation provides a novel means of controlling Tat-interactive protein 60 kDa function.

  1. Counterintuitive electron localisation from density-functional theory with polarisable solvent models

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dale, Stephen G., E-mail: sdale@ucmerced.edu; Johnson, Erin R., E-mail: erin.johnson@dal.ca

    2015-11-14

    Exploration of the solvated electron phenomena using density-functional theory (DFT) generally results in prediction of a localised electron within an induced solvent cavity. However, it is well known that DFT favours highly delocalised charges, rendering the localisation of a solvated electron unexpected. We explore the origins of this counterintuitive behaviour using a model Kevan-structure system. When a polarisable-continuum solvent model is included, it forces electron localisation by introducing a strong energetic bias that favours integer charges. This results in the formation of a large energetic barrier for charge-hopping and can cause the self-consistent field to become trapped in local minimamore » thus converging to stable solutions that are higher in energy than the ground electronic state. Finally, since the bias towards integer charges is caused by the polarisable continuum, these findings will also apply to other classical polarisation corrections, as in combined quantum mechanics and molecular mechanics (QM/MM) methods. The implications for systems beyond the solvated electron, including cationic DNA bases, are discussed.« less

  2. The geometry of propagating rifts

    NASA Astrophysics Data System (ADS)

    McKenzie, Dan

    1986-03-01

    The kinematics of two different processes are investigated, both of which have been described as rift propagation. Courtillot uses this term to describe the change from distributed to localised extension which occurs during the early development of an ocean basin. The term localisation is instead used here to describe this process, to distinguish it from Hey's type of propagation. Localisation generally leads to rotation of the direction of magnetisation. To Hey propagation means the extension of a rift into the undeformed plate beyond a transform fault. Detail surveys of the Galapagos rift have shown that the propagating and failing rifts are not connected by a single transform fault, but by a zone which is undergoing shear. The principal deformation is simple shear, and the kinematics of this deformation are investigated in some detail. The strike of most of the lineations observed in the area can be produced by such deformation. The mode of extension on the propagating rift appears to be localised for some periods but to be distributed for others. Neither simple kinematic arguments nor stretching of the lithosphere with conservation of crust can account for the observed variations in water depth.

  3. Reliability of horizontal and vertical tube shift techniques in the localisation of supernumerary teeth.

    PubMed

    Mallineni, S K; Anthonappa, R P; King, N M

    2016-12-01

    To assess the reliability of the vertical tube shift technique (VTST) and horizontal tube shift technique (HTST) for the localisation of unerupted supernumerary teeth (ST) in the anterior region of the maxilla. A convenience sample of 83 patients who attended a major teaching hospital because of unerupted ST was selected. Only non-syndromic patients with ST and who had complete clinical and radiographic and surgical records were included in the study. Ten examiners independently rated the paired set of radiographs for each technique. Chi-square test, paired t test and kappa statistics were employed to assess the intra- and inter-examiner reliability. Paired sets of 1660 radiographs (830 pairs for each technique) were available for the analysis. The overall sensitivity for VTST and HTST was 80.6 and 72.1% respectively, with slight inter-examiner and good intra-examiner reliability. Statistically significant differences were evident between the two localisation techniques (p < 0.05). Localisation of unerupted ST using VTST was more successful than HTST in the anterior region of the maxilla.

  4. Intracellular localisation of proteins to specific cellular areas by nanocapsule mediated delivery.

    PubMed

    Wang, Huabin; Chen, Ligang; Sun, Xianchao; Fu, Ailing

    2017-09-01

    Nanocapsules are promising carriers with great potential for intracellular protein transport. Although many studies have intended to improve cell uptake efficacy, there is an increasing interest in understanding of subcellular distribution of cargoes inside cells, which is essential for purposeful delivery of biomolecules into specific sites within cells. Herein, we interrogate the intracellular localisation of exogenous proteins, including fluorescein isothiocyanate (FITC)-labelled bovine serum albumin (BSA) and green fluorescent protein (GFP), mediated by specially designed nanocapsules. The results show that the designed nanocapsules can deliver the two types of fluorescent proteins into different cellular destinations (cytosol, nucleus or the whole cell), depending on the composition of nanocapsules. Meanwhile, several impact factors that influence the distribution of proteins in cells have also been investigated, and the results suggest that the localisation of capsule-mediated proteins in cells is strongly affected by the surface properties of nanocapsules, the types of stabilisers and proteins, and environmental temperatures. The rational control of intracellular localised delivery of exogenous proteins as we demonstrated in this study might open new avenues to obtain desired magnitude of drug effects for modulating cell activity.

  5. Mechanisms for localising calcineurin and CaMKII in dendritic spines.

    PubMed

    Penny, Christopher J; Gold, Matthew G

    2018-05-27

    Calcineurin and calmodulin-dependent protein kinase II (CaMKII) are both highly abundant in neurons, and both are activated by calmodulin at similar Ca 2+ concentrations in the test tube. However, they fulfill opposite functions in dendritic spines, with CaMKII activity driving long-term synaptic potentiation following large influxes of Ca 2+ through NMDA-type glutamate receptors (NMDARs), and calcineurin responding to smaller influxes of Ca 2+ through the same receptors to induce long-term depression. In this review, we explore the notion that precise dynamic localisation of the two enzymes at different sites within dendritic spines is fundamental to this behavior. We describe the structural basis of calcineurin and CaMKII localisation by their interaction with proteins including AKAP79, densin-180, α-actinin, and NMDARs. We then consider how interactions with these proteins likely position calcineurin and CaMKII at different distances from Ca 2+ microdomains emanating from the mouths of NMDARs in order to drive the divergent responses. We also highlight shortcomings in our current understanding of synaptic localisation of these two important signalling enzymes. Copyright © 2017. Published by Elsevier Inc.

  6. Identification of unusual events in multi-channel bridge monitoring data

    NASA Astrophysics Data System (ADS)

    Omenzetter, Piotr; Brownjohn, James Mark William; Moyo, Pilate

    2004-03-01

    Continuously operating instrumented structural health monitoring (SHM) systems are becoming a practical alternative to replace visual inspection for assessment of condition and soundness of civil infrastructure such as bridges. However, converting large amounts of data from an SHM system into usable information is a great challenge to which special signal processing techniques must be applied. This study is devoted to identification of abrupt, anomalous and potentially onerous events in the time histories of static, hourly sampled strains recorded by a multi-sensor SHM system installed in a major bridge structure and operating continuously for a long time. Such events may result, among other causes, from sudden settlement of foundation, ground movement, excessive traffic load or failure of post-tensioning cables. A method of outlier detection in multivariate data has been applied to the problem of finding and localising sudden events in the strain data. For sharp discrimination of abrupt strain changes from slowly varying ones wavelet transform has been used. The proposed method has been successfully tested using known events recorded during construction of the bridge, and later effectively used for detection of anomalous post-construction events.

  7. Membrane glucocorticoid receptors are localised in the extracellular matrix and signal through the MAPK pathway in mammalian skeletal muscle fibres

    PubMed Central

    Boncompagni, Simona; Arthurton, Lewis; Akujuru, Eugene; Pearson, Timothy; Steverding, Dietmar; Protasi, Feliciano; Mutungi, Gabriel

    2015-01-01

    A number of studies have previously proposed the existence of glucocorticoid receptors on the plasma membrane of many cell types, including skeletal muscle fibres. However, their exact localisation and the cellular signalling pathway(s) they utilise to communicate with the rest of the cell are still poorly understood. In this study, we investigated the localisation and the mechanism(s) underlying the non-genomic physiological functions of these receptors in mouse skeletal muscle cells. The results show that the receptors were localised in the cytoplasm in myoblasts, in the nucleus in myotubes, in the extracellular matrix, in satellite cells and in the proximity of mitochondria in adult muscle fibres. Also, they bound laminin in a glucocorticoid-dependent manner. Treating small skeletal muscle fibre bundles with the synthetic glucocorticoid beclomethasone dipropionate increased the phosphorylation (= activation) of extracellular signal-regulated kinases 1 and 2, c-Jun N-terminal kinase and p38 mitogen-activated protein kinase. This occurred within 5 min and depended on the fibre type and the duration of the treatment. It was also abolished by the glucocorticoid receptor inhibitor, mifepristone, and a monoclonal antibody against the receptor. From these results we conclude that the non-genomic/non-canonical physiological functions of glucocorticoids, in adult skeletal muscle fibres, are mediated by a glucocorticoid receptor localised in the extracellular matrix, in satellite cells and close to mitochondria, and involve activation of the mitogen-activated protein kinase pathway. PMID:25846902

  8. Novel technology of molecular radio-guidance for lymph node dissection in recurrent prostate cancer by PSMA-ligands.

    PubMed

    Rauscher, Isabel; Horn, Thomas; Eiber, Matthias; Gschwend, Jürgen E; Maurer, Tobias

    2018-04-01

    Recently, prostate-specific membrane antigen-radioguided surgery (PSMA-RGS) has been introduced as a promising new and individual treatment concept in patients with localised recurrent prostate cancer (PC). In the following, we want to review our experience with PSMA-RGS in patients with localised biochemical recurrent PC. A non-systematic review of the literature was carried out with focus on technical and logistical aspects of PSMA-RGS. Furthermore, published data on intraoperative detection of metastatic lesions compared to preoperative PSMA-PET and postoperative histopathology, postoperative complications as well as oncological follow-up data are summarized. Finally, relevant aspects on prerequisites for PSMA-RGS, patient selection, and the potential benefit of additional salvage radiotherapy or potential future applications of robotic PSMA-RGS with drop-in γ-probes are discussed. First results show that PSMA-RGS is very sensitive and specific in tracking suspicious lesions intraoperatively. Prerequisite for patient selection and localisation of tumour recurrence is a positive Ga-HBED-CC PSMA positron-emission tomography (PET) scan with preferably only singular soft tissue or lymph node recurrence after primary treatment. Furthermore, PSMA-RGS has the potential to positively influence oncological outcome. PSMA-RGS seems to be of high value in patients with localised PC recurrence for exact localisation and resection of oftentimes small metastatic lesions using intraoperative and ex vivo γ-probe measurements. However, patient identification on the basis of Ga-HBED-CC-PSMA PET imaging as well as clinical parameters is crucial to obtain satisfactory results.

  9. Determinants of GPI-PLC Localisation to the Flagellum and Access to GPI-Anchored Substrates in Trypanosomes

    PubMed Central

    Sunter, Jack; Webb, Helena; Carrington, Mark

    2013-01-01

    In Trypanosoma brucei, glycosylphosphatidylinositol phospholipase C (GPI-PLC) is a virulence factor that releases variant surface glycoprotein (VSG) from dying cells. In live cells, GPI-PLC is localised to the plasma membrane where it is concentrated on the flagellar membrane, so activity or access must be tightly regulated as very little VSG is shed. Little is known about regulation except that acylation within a short internal motif containing three cysteines is necessary for GPI-PLC to access VSG in dying cells. Here, GPI-PLC mutants have been analysed both for subcellular localisation and for the ability to release VSG from dying cells. Two sequence determinants necessary for concentration on the flagellar membrane were identified. First, all three cysteines are required for full concentration on the flagellar membrane. Mutants with two cysteines localise predominantly to the plasma membrane but lose some of their flagellar concentration, while mutants with one cysteine are mainly localised to membranes between the nucleus and flagellar pocket. Second, a proline residue close to the C-terminus, and distant from the acylated cysteines, is necessary for concentration on the flagellar membrane. The localisation of GPI-PLC to the plasma but not flagellar membrane is necessary for access to the VSG in dying cells. Cellular structures necessary for concentration on the flagellar membrane were identified by depletion of components. Disruption of the flagellar pocket collar caused loss of concentration whereas detachment of the flagellum from the cell body after disruption of the flagellar attachment zone did not. Thus, targeting to the flagellar membrane requires: a titratable level of acylation, a motif including a proline, and a functional flagellar pocket. These results provide an insight into how the segregation of flagellar membrane proteins from those present in the flagellar pocket and cell body membranes is achieved. PMID:23990786

  10. Modelling of deformation around magmatic intrusions with application to gold-related structures in the Yilgarn Craton, Western Australia

    NASA Astrophysics Data System (ADS)

    Zhang, Y.; Karrech, A.; Schaubs, P. M.; Regenauer-Lieb, K.; Poulet, T.; Cleverley, J. S.

    2012-03-01

    This study simulates rock deformation around high temperature granite intrusions and explores how gold bearing shear zones near intrusions were developed in the Yilgarn, using a new continuum damage mechanics algorithm that considers the temperature and time dependent elastic-visco-plastic constitutive behaviour of crustal materials. The results demonstrate that strain rates have the most significant effects on structural patterns for both extensional and compressional cases. Smaller strain rates promote the formation of narrow high-strain shear zones and strong strain localisation along the flank or shoulder areas of the intrusion and cold granite dome. Wider diffuse shear zones are developed under higher strain rates due to strain hardening. The cooling of the intrusion to background temperatures occurred over a much shorter time interval when compared to the duration of deformation and shear zones development. Strong strain localisation near the intrusion and shear zone development in the crust occurred under both extensional and compressional conditions. There is always clear strain localisation around the shoulders of the intrusion and the flanks of the "cold" granitic dome in early deformation stages. In the models containing a pre-existing fault, strain localisation near the intrusion became asymmetric with much stronger localisation and the development of a damage zone at the shoulder adjacent to the reactivated fault. At higher deformation stages, the models produced a range of structural patterns including graben and half graben basin (extension), "pop-up" wedge structures (compression), tilted fault blocks and switch of shear movement from reverse to normal on shear zones. The model explains in part why a number of gold deposits (e.g. Wallaby and Paddington deposits) in the Yilgarn were formed near the flank of granite-cored domes and deep "tapping" faults, and shows that the new modelling approach is capable of realistically simulating high strain localisation and shear zone development.

  11. Feasibility of imaging epileptic seizure onset with EIT and depth electrodes.

    PubMed

    Witkowska-Wrobel, Anna; Aristovich, Kirill; Faulkner, Mayo; Avery, James; Holder, David

    2018-06-01

    Imaging ictal and interictal activity with Electrical Impedance Tomography (EIT) using intracranial electrode mats has been demonstrated in animal models of epilepsy. In human epilepsy subjects undergoing presurgical evaluation, depth electrodes are often preferred. The purpose of this work was to evaluate the feasibility of using EIT to localise epileptogenic areas with intracranial electrodes in humans. The accuracy of localisation of the ictal onset zone was evaluated in computer simulations using 9M element FEM models derived from three subjects. 5 mm radius perturbations imitating a single seizure onset event were placed in several locations forming two groups: under depth electrode coverage and in the contralateral hemisphere. Simulations were made for impedance changes of 1% expected for neuronal depolarisation over milliseconds and 10% for cell swelling over seconds. Reconstructions were compared with EEG source modelling for a radially orientated dipole with respect to the closest EEG recording contact. The best accuracy of EIT was obtained using all depth and 32 scalp electrodes, greater than the equivalent accuracy with EEG inverse source modelling. The localisation error was 5.2 ± 1.8, 4.3 ± 0 and 46.2 ± 25.8 mm for perturbations within the volume enclosed by depth electrodes and 29.6 ± 38.7, 26.1 ± 36.2, 54.0 ± 26.2 mm for those without (EIT 1%, 10% change, EEG source modelling, n = 15 in 3 subjects, p < 0.01). As EIT was insensitive to source dipole orientation, all 15 perturbations within the volume enclosed by depth electrodes were localised, whereas the standard clinical method of visual inspection of EEG voltages, only localised 8 out of 15 cases. This suggests that adding EIT to SEEG measurements could be beneficial in localising the onset of seizures. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

  12. The surgical manegement of metastases to humerus-clinical evaluation.

    PubMed

    Chrobok, Adam; Spindel, Jerzy; Miszczyk, Leszek; Koczy, Bogdan; Pilecki, Bogdan; Jarosz, Adam; Mrozek, Tomasz

    2003-06-30

    Background. The humerus is a common localisation of cancer metastases. The restoration of anatomical order and tumor resection within humerus is important for patients quality of everyday life and for their pain relief. The surgical treatment is one of the most important part of the whole oncological ways of tratment.
    The study objective was a clinical assesment of tumor resection and reconstruction within humerus according to matastasis localisation and the choice of surgical technique.
    Material and methods. In the years 1999-2002 19 patients underwent surgery due to pathological fracture or/and cancer metastasis within humerus. The shaft localisation of the tumor was found in 8 cases and in 11 patients the metastatic foci were found in proximnal diaphysis. In patients with proximal diaphysis localisation of the tumor the partial resection with subsequent joint exchange procedure was made. The humeral shaft metastatic cancer changes were treated by the segmental resection with subsequent surgical cement filling or auto/allogenical bone grafting combined with intramedullary nail or AO/ASIF plate stabilisation. The average follow-up period was 8,5 months.
    Results. In patients after resection with shoulder joint alloplasty according to the Enneking test a very good result was found in 7 and very good in 4 cases.
    In patients with femoral shaft metastatic tumor locaslisation, 6 good and 2 fair results were found. In 1 patient after 2 months rehabilitation a reoperation was needed due to the mechanical destabilisation. The best results were found in patients after intramedullary nailing.An acute soft tissue inflamation requiering surgical treatment was found in 1 patient after shoulder joint replacement.
    Conclusions. After clinical analysis of the material we highly recomend the partial humeral bone resection with subsequent shoulder alloplasty in patients with proximal humeral diaphysis metastatic localisation. In cases with shaft localisation a better results were found after intramedullary nailing compared to common plate technique.

  13. Torque efficiency of square and rectangular archwires into 0.018 and 0.022 in. conventional brackets.

    PubMed

    Papageorgiou, Spyridon N; Sifakakis, Iosif; Doulis, Ioannis; Eliades, Theodore; Bourauel, Christoph

    2016-01-01

    The aim of this study was to compare the torque efficacy of square and rectangular wires in 0.018- and 0.022-in. conventionally ligated brackets. Brackets of the same prescription were evaluated in both slot dimensions. Identical acrylic resin models of the maxilla were bonded with the brackets and mounted on the Orthodontic Measurement and Simulation System. Ten 0.018 × 0.018 in., 0.018 × 0.022 in., and 0.018 × 0.025 in. stainless steel wires were evaluated in the 0.018-in. brackets and ten 0.019 × 0.019 in., 0.019 × 0.025 in., and 0.019 × 0.026 in. stainless steel wires were evaluated in the 0.022-in. brackets. A 15° buccal root torque was gradually applied to the right central incisor bracket, and the moments were recorded at this position. One-way ANOVA was applied for both bracket slot sizes along with post hoc analysis for the various archwire sizes. The mean measured moments varied between 10.78 and 30.60 Nmm among the assessed wire-and-bracket combinations. Both square and rectangular archwires in the 0.018-in. bracket system exerted statistically significantly higher moments in comparison with their counterparts in the 0.022-in. bracket system. Rectangular archwires exerted statistically significantly higher moments than square archwires, both for the 0.018- and the 0.022-in. bracket system. Rectangular archwires seem to be more efficient in torque exertion, especially in 0.018-in. brackets.

  14. Corrosion Induced Loss of Capacity and Development of a Guided Wave Condition Assessment Method for Multistrand Anchor Systems Used in Corps Projects

    DTIC Science & Technology

    2014-08-01

    installing high-capacity, post-tensioned foundation anchors. These stressed steel tendons have been used to strengthen hydraulic concrete structures and to...Field Inspection in Mass Concrete .................................... 32 3.3 NDT Technologies in General for Seven Strand Wire Cable Inspection...rod end of a 1.31-inch-diameter grease embedded trunion anchor rod with concrete termination. ..................... 37 Figure 32. 441 Khz narrow

  15. A clip-based protocol for breast boost radiotherapy provides clear target visualisation and demonstrates significant volume reduction over time

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lewis, Lorraine; Cox, Jennifer; Faculty of Health Sciences, University of Sydney, Sydney, New South Wales

    2015-09-15

    The clinical target volume (CTV) for early stage breast cancer is difficult to clearly identify on planning computed tomography (CT) scans. Surgical clips inserted around the tumour bed should help to identify the CTV, particularly if the seroma has been reabsorbed, and enable tracking of CTV changes over time. A surgical clip-based CTV delineation protocol was introduced. CTV visibility and its post-operative shrinkage pattern were assessed. The subjects were 27 early stage breast cancer patients receiving post-operative radiotherapy alone and 15 receiving post-operative chemotherapy followed by radiotherapy. The radiotherapy alone (RT/alone) group received a CT scan at median 25 daysmore » post-operatively (CT1rt) and another at 40 Gy, median 68 days (CT2rt). The chemotherapy/RT group (chemo/RT) received a CT scan at median 18 days post-operatively (CT1ch), a planning CT scan at median 126 days (CT2ch), and another at 40 Gy (CT3ch). There was no significant difference (P = 0.08) between the initial mean CTV for each cohort. The RT/alone cohort showed significant CTV volume reduction of 38.4% (P = 0.01) at 40 Gy. The Chemo/RT cohort had significantly reduced volumes between CT1ch: median 54 cm{sup 3} (4–118) and CT2ch: median 16 cm{sup 3}, (2–99), (P = 0.01), but no significant volume reduction thereafter. Surgical clips enable localisation of the post-surgical seroma for radiotherapy targeting. Most seroma shrinkage occurs early, enabling CT treatment planning to take place at 7 weeks, which is within the 9 weeks recommended to limit disease recurrence.« less

  16. Jaw symptoms and signs and the connection to cranial cervical symptoms and post-traumatic stress during the first year after a whiplash trauma.

    PubMed

    Severinsson, Yvonne; Bunketorp, Olle; Wenneberg, Bengt

    2010-01-01

    To estimate the prevalence of jaw symptoms and signs during the first year after a neck sprain in a car collision. Further, to determine their relationships to the localisation and grade of the initial neck symptoms and signs, headache, post-traumatic stress and crash characteristics. One hundred and forty-six adult subjects and crash characteristics were prospectively investigated in an in-depth study during 1997-2001. Head, neck, and jaw symptoms and signs were recorded within 5 weeks and after 1 year. Acute post-traumatic stress was estimated with the Impact of Event Scale-Revised (IES-R). Jaw symptoms were initially reported by three men (5%) and three women (4%), and subsequently developed in eight women (10%) during the following year. Jaw signs were noted initially in 53 subjects (37%) and in 28 subjects (24%) after 1 year, without difference between sexes, and more often after low-speed impacts. Headache in females, cranial cervical symptoms, pronounced neck problems, post-traumatic stress and whiplash-associated disorders (WAD) grade II-III after rear-end impacts were related to jaw signs during the acute phase. After 1 year, jaw signs were related to residual neck problems, headache and post-traumatic stress. Jaw symptoms are seldom reported during the acute phase after a whiplash trauma. Women more often than men develop jaw symptoms during the first year. Jaw symptoms and signs may develop also after low-speed impacts, especially after rear-end collisions. Jaw symptoms and signs should be observed after whiplash trauma, especially in those with headache, pronounced neck problems, cranial neck symptoms and post-traumatic stress.

  17. Functionalized gold nanoparticles manifested as potent carriers for nucleolar targeting

    NASA Astrophysics Data System (ADS)

    Shahbazi, Reza; Ozcicek, Ilyas; Ozturk, Gurkan; Ulubayram, Kezban

    2017-01-01

    It is generally known that gold nanoparticles are localised in the cytoplasm and, if synthesised in small sizes or functionalized with specific proteins, they enter the cell nucleus. However, there is no report emphasising the importance of surface functionalization in their accumulation in the nucleolus. Here, for the first time in the literature, it is proposed that functionalization of gold nanoparticles with a thin layer of polyethyleneimine (PEI) spearheads them to the nucleolus of hard-to-transfect post-mitotic dorsal root ganglion neurones in a size-independent manner. As a potential for theranostic applications, it was found that functionalization with a thin layer of PEI affected the emission signal intensity of gold nanoparticles so that the cellular biodistribution of nanoparticles was visualised clearly under both confocal and two-photon microscopes.

  18. Long-term biatrial recordings in post-operative atrial fibrillation.

    PubMed

    Masè, M; Graffigna, A; Sinelli, S; Pallaoro, G; Nollo, G; Ravelli, F

    2010-01-01

    Although atrial fibrillation (AF) is a common complication of cardiac surgery, its pathophysiology remains unclear. The study of post-operative AF demands for the recording of cardiac electrical activity in correspondence of AF onset and progression. Long-term recordings in post-surgery patients could provide this information, but, to date, have been limited to surface signals, which precludes a characterization of the arrhythmic triggers and substrate. In this study we demonstrate the feasibility of a continuous long-term recording of atrial electrical activities from the right and left atria in post-surgery patients. Local atrial epicardial electrograms are acquired by positioning temporary pacing wires in the right and left atria at the end of the intervention, while three day recordings are obtained by a digital holter recorder, adapted to epicardial signal features. The capability of the system to map local atrial activity and the possibility to obtain quantitative information on atrial rate and synchronization from the processed epicardial signals are proven in representative examples. The quantitative description of local atrial properties opens new perspective in the investigation of post-surgery AF.

  19. Effects produced by CDU improvement of resist pattern with PEB temperature control for wiring resistance variation reduction

    NASA Astrophysics Data System (ADS)

    Tadokoro, Masahide; Shinozuka, Shinichi; Ogata, Kunie; Morimoto, Tamotsu

    2008-03-01

    Semiconductor manufacturing technology has shifted towards finer design rules, and demands for critical dimension uniformity (CDU) of resist patterns have become greater than ever. One of the methods for improving CDU of resist pattern is to control the temperature of post-exposure bake (PEB). When ArF resist is used, there is a certain relationship between critical dimension (CD) and PEB temperature. By utilizing this relationship, Resist Pattern CDU can be improved through control of within-wafer temperature distribution in the PEB process. We have already applied this method to Resist Pattern CDU improvement and have achieved these results. In this evaluation, we aim at: 1. Clarifying the relationship between the improvement in Resist Pattern CDU through PEB temperature control and the improvement in Etching Pattern CDU. 2. Verifying whether Resist Pattern CDU improvement through PEB temperature control has any effect on the reduction in wiring resistance variation. The evaluation procedure is: 1. Preparation of wafers with base film of doped Poly-Si (D-Poly). 2. Creation of two sets of samples on the base, a set of samples with good Resist Pattern CDU and a set of samples with poor Resist Pattern CDU. 3. Etching of the two sets under the same conditions. 4. Measurements of CD and wiring resistance. We used Optical CD Measurement (OCD) for measurement of resist pattern and etching pattern for the reason that OCD is minimally affected by Line Edge Roughness (LER). As a result, we found that; 1. The improvement in Resist Pattern CDU leads to the improvement in Etching Pattern CDU . 2. The improvement in Resist Pattern CDU has an effect on the reduction in wiring resistance variation. There is a cause-and-effect relationship between wiring resistance variation and transistor characteristics. From this relationship, we expect that the improvement in Resist Pattern CDU through PEB temperature control can contribute to device performance improvement.

  20. Operational verification of a 40-MHz annular array transducer

    PubMed Central

    Ketterling, Jeffrey A.; Ramachandran, Sarayu; Aristizäbal, Orlando

    2006-01-01

    An experimental system to take advantage of the imaging capabilities of a 5-ring polyvinylidene fluoride (PVDF) based annular array is presented. The array has a 6 mm total aperture and a 12 mm geometric focus. The experimental system is designed to pulse a single element of the array and then digitize the received data of all array channels simultaneously. All transmit/receive pairs are digitized and then the data are post-processed with a synthetic focusing technique to achieve an enhanced depth of field (DOF). The performance of the array is experimentally tested with a wire phantom consisting of 25-μm diameter wires diagonally spaced at 1 mm by 1 mm intervals. The phantom permitted the efficacy of the synthetic focusing algorithm to be tested and was also used for two-way beam characterization. Experimental results are compared to a spatial impulse response method beam simulation. After synthetic focusing, the two-way echo amplitude was enhanced over the range of 8 to 19 mm and the 6-dB DOF spanned from 9 to 15 mm. For a wire at a fixed axial depth, the relative time delays between transmit/receive ring pairs agreed with theoretical predictions to within ± 2 ns. To further test the system, B-mode images of an excised bovine eye are rendered. PMID:16555771

  1. Friction Forces during Sliding of Various Brackets for Malaligned Teeth: An In Vitro Study

    PubMed Central

    Crincoli, Vito; Di Bisceglie, Maria Beatrice; Balsamo, Antonio; Serpico, Vitaliano; Chiatante, Francesco; Pappalettere, Carmine; Boccaccio, Antonio

    2013-01-01

    Aims. To measure the friction force generated during sliding mechanics with conventional, self-ligating (Damon 3 mx, Smart Clip, and Time 3) and low-friction (Synergy) brackets using different archwire diameters and ligating systems in the presence of apical and buccal malalignments of the canine. Methods. An experimental setup reproducing the right buccal segment of the maxillary arch was designed to measure the friction force generated at the bracket/wire and wire/ligature interfaces of different brackets. A complete factorial plan was drawn up and a three-way analysis of variance (ANOVA) was carried out to investigate whether the following factors affect the values of friction force: (i) degree of malalignment, (ii) diameter of the orthodontic wire, and (iii) bracket/ligature combination. Tukey post hoc test was also conducted to evaluate any statistically significant differences between the bracket/ligature combinations analyzed. Results. ANOVA showed that all the above factors affect the friction force values. The friction force released during sliding mechanics with conventional brackets is about 5-6times higher than that released with the other investigated brackets. A quasilinear increase of the frictional forces was observed for increasing amounts of apical and buccal malalignments. Conclusion. The Synergy bracket with silicone ligature placed around the inner tie-wings appears to yield the best performance. PMID:23533364

  2. Percutaneous K-Wire Fixation for Femur Shaft Fractures in Children: A Treatment Concepts for Developing Countries

    PubMed Central

    Sahu, RL

    2013-01-01

    Background: Fractures shaft femur is a major cause of morbidity and mortality in patients with lower extremity injuries. Aims: The aim of this study was to evaluate the efficacy of intramedullary Kirschner wires for the treatment of femoral shaft fracture in children. Subjects and Methods: This prospective study was conducted in the Department of Orthopaedic surgery in M. M. Medical College from June 2005 to June 2010. Sixty eight children with a mean age of 7.7 years (range, 2-14 years) were recruited from Emergency and out patient department having closed fracture of femoral shaft. All patients were operated under general anesthesia. All patients were followed for twelve months. Results: Out of sixty eight patients, sixty four patients underwent union in 42 to 70 days with a mean of 56 days. Touch down weight bearing was started on 2nd post-operative day. Complications found in four patients who had insignificant delayed union which were united next three weeks. Intramedullary Kirschner-wires were removed after an average of five months without any complications. The results were excellent in 94.1% (64/68) and good in 5.8% (4/68). Conclusion: This technique is simple, quick to perform, safe and reliable and avoids prolonged hospitalization with good results and is economical. PMID:23919189

  3. Globalisation and Localisation in Music Education in Hong Kong and Taiwan

    ERIC Educational Resources Information Center

    Ho, Wai-Chung

    2013-01-01

    The purpose of the study is to analyse and discuss the influences of globalisation and localisation on music education in Hong Kong and Taiwan. It argues that the reform of music education concerns changes to the contents of the curriculum that envisage the cultural and political developments that arise from processes of globalisation and…

  4. The management of anterior tooth wear using gold palatal veneers in canine guidance.

    PubMed

    Eliyas, S; Martin, N

    2013-03-01

    Localised anterior tooth wear can be managed using minimally invasive techniques with conservation of tooth structure and preservation of pulp vitality. This article describes and illustrates with two clinical cases, the management of localised tooth wear, with the restoration of canine guidance by a combination of gold palatal veneers and direct composite restorations.

  5. Application of the Localisation Platform Crowdin in Translator Education

    ERIC Educational Resources Information Center

    Kudla, Dominik

    2017-01-01

    This article is an attempt to briefly describe the potential of the online localisation platform Crowdin for the education of the future translators at universities and in private courses or workshops. This description is provided on the basis of the information gathered through the user experience of the author and uses the example of the Khan…

  6. Robust weak anti-localisation effect in strongly textured nanocrystalline Bi2Se3 samples

    NASA Astrophysics Data System (ADS)

    Pereira, V. M. M.; Henriques, M. S. C.; Paixão, J. A.

    2018-05-01

    Topological insulators are a quantum state of matter that has recently created a great interest among the scientific community, with Bi2Se3 being one of the most extensively studied materials. Here, we demonstrate that polycrystalline nanostructured samples of Bi2Se3 preserve the existence of topological surface states, where electrons cannot be localised. The nanosheet crystals were synthesised by a microwave-assisted method and their structure, composition and morphology thoroughly characterised. The transport properties of a textured polycrystalline sample with strong preferred orientation along the c-axis were measured, showing the presence of the weak anti-localisation effect and Shubnikov-de Haas oscillations. These features are robust against the presence of non-magnetic impurities and structural defects.

  7. The atomic structure of polar and non-polar InGaN quantum wells and the green gap problem.

    PubMed

    Humphreys, C J; Griffiths, J T; Tang, F; Oehler, F; Findlay, S D; Zheng, C; Etheridge, J; Martin, T L; Bagot, P A J; Moody, M P; Sutherland, D; Dawson, P; Schulz, S; Zhang, S; Fu, W Y; Zhu, T; Kappers, M J; Oliver, R A

    2017-05-01

    We have used high resolution transmission electron microscopy (HRTEM), aberration-corrected quantitative scanning transmission electron microscopy (Q-STEM), atom probe tomography (APT) and X-ray diffraction (XRD) to study the atomic structure of (0001) polar and (11-20) non-polar InGaN quantum wells (QWs). This paper provides an overview of the results. Polar (0001) InGaN in QWs is a random alloy, with In replacing Ga randomly. The InGaN QWs have atomic height interface steps, resulting in QW width fluctuations. The electrons are localised at the top QW interface by the built-in electric field and the well-width fluctuations, with a localisation energy of typically 20meV. The holes are localised near the bottom QW interface, by indium fluctuations in the random alloy, with a localisation energy of typically 60meV. On the other hand, the non-polar (11-20) InGaN QWs contain nanometre-scale indium-rich clusters which we suggest localise the carriers and produce longer wavelength (lower energy) emission than from random alloy non-polar InGaN QWs of the same average composition. The reason for the indium-rich clusters in non-polar (11-20) InGaN QWs is not yet clear, but may be connected to the lower QW growth temperature for the (11-20) InGaN QWs compared to the (0001) polar InGaN QWs. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  8. The cost-effectiveness of active surveillance compared to watchful waiting and radical prostatectomy for low risk localised prostate cancer.

    PubMed

    Lao, Chunhuan; Edlin, Richard; Rouse, Paul; Brown, Charis; Holmes, Michael; Gilling, Peter; Lawrenson, Ross

    2017-08-08

    Radical prostatectomy is the most common treatment for localised prostate cancer in New Zealand. Active surveillance was introduced to prevent overtreatment and reduce costs while preserving the option of radical prostatectomy. This study aims to evaluate the cost-effectiveness of active surveillance compared to watchful waiting and radical prostatectomy. Markov models were constructed to estimate the life-time cost-effectiveness of active surveillance compared to watchful waiting and radical prostatectomy for low risk localised prostate cancer patients aged 45-70 years, using national datasets in New Zealand and published studies including the SPCG-4 study. This study was from the perspective of the Ministry of Health in New Zealand. Radical prostatectomy is less costly than active surveillance in men aged 45-55 years with low risk localised prostate cancer, but more costly for men aged 60-70 years. Scenario analyses demonstrated significant uncertainty as to the most cost-effective option in all age groups because of the unavailability of good quality of life data for men under active surveillance. Uncertainties around the likelihood of having radical prostatectomy when managed with active surveillance also affect the cost-effectiveness of active surveillance against radical prostatectomy. Active surveillance is less likely to be cost-effective compared to radical prostatectomy for younger men diagnosed with low risk localised prostate cancer. The cost-effectiveness of active surveillance compared to radical prostatectomy is critically dependent on the 'trigger' for radical prostatectomy and the quality of life in men on active surveillance. Research on the latter would be beneficial.

  9. Exploring the Function of Online Narratives to Develop Critical Thinking and Localisation of Knowledge in an International Science Program

    ERIC Educational Resources Information Center

    Hicks, Marianne; Tham, Melissa; Brookes, Rowan

    2017-01-01

    e-learning practitioners have long recognised the benefits of using online training to achieve knowledge transfer, less is understood about facilitating the sharing of values, attitudes, critical thinking, and localisation using online platforms. In this article an online learning platform in the context of an international scientific program was…

  10. Nonlinear Light Dynamics in Multi-Core Structures

    DTIC Science & Technology

    2017-02-27

    be generated in continuous- discrete optical media such as multi-core optical fiber or waveguide arrays; localisation dynamics in a continuous... discrete nonlinear system. Detailed theoretical analysis is presented of the existence and stability of the discrete -continuous light bullets using a very...and pulse compression using wave collapse (self-focusing) energy localisation dynamics in a continuous- discrete nonlinear system, as implemented in a

  11. Gradual collapse of nuclear wave functions regulated by frequency tuned X-ray scattering.

    PubMed

    Ignatova, Nina; Cruz, Vinícius V; Couto, Rafael C; Ertan, Emelie; Zimin, Andrey; Guimarães, Freddy F; Polyutov, Sergey; Ågren, Hans; Kimberg, Victor; Odelius, Michael; Gel'mukhanov, Faris

    2017-03-07

    As is well established, the symmetry breaking by isotope substitution in the water molecule results in localisation of the vibrations along one of the two bonds in the ground state. In this study we find that this localisation may be broken in excited electronic states. Contrary to the ground state, the stretching vibrations of HDO are delocalised in the bound core-excited state in spite of the mass difference between hydrogen and deuterium. The reason for this effect can be traced to the narrow "canyon-like" shape of the potential of the state along the symmetric stretching mode, which dominates over the localisation mass-difference effect. In contrast, the localisation of nuclear motion to one of the HDO bonds is preserved in the dissociative core-excited state . The dynamics of the delocalisation of nuclear motion in these core-excited states is studied using resonant inelastic X-ray scattering of the vibrationally excited HDO molecule. The results shed light on the process of a wave function collapse. After core-excitation into the state of HDO the initial wave packet collapses gradually, rather than instantaneously, to a single vibrational eigenstate.

  12. Aquaporins 7 and 11 in boar spermatozoa: detection, localisation and relationship with sperm quality.

    PubMed

    Prieto-Martínez, Noelia; Vilagran, Ingrid; Morató, Roser; Rodríguez-Gil, Joan E; Yeste, Marc; Bonet, Sergi

    2016-04-01

    Aquaporins (AQPs) are integral membrane water channels that allow transport of water and small solutes across cell membranes. Although water permeability is known to play a critical role in mammalian cells, including spermatozoa, little is known about their localisation in boar spermatozoa. Two aquaporins, AQP7 and AQP11, in boar spermatozoa were identified by western blotting and localised through immunocytochemistry analyses. Western blot results showed that boar spermatozoa expressed AQP7 (25kDa) and AQP11 (50kDa). Immunocytochemistry analyses demonstrated that AQP7 was localised in the connecting piece of boar spermatozoa, while AQP11 was found in the head and mid-piece and diffuse labelling was also seen along the tail. Despite differences in AQP7 and AQP11 content between boar ejaculates, these differences were not found to be correlated with sperm quality in the case of AQP7. Conversely, AQP11 content showed a significant correlation (P<0.05) with sperm membrane integrity and fluidity and sperm motility. In conclusion, boar spermatozoa express AQP7 and AQP11, and the amounts of AQP11 but not those of AQP7 are correlated with sperm motility and membrane integrity.

  13. Fully localised nonlinear energy growth optimals in pipe flow

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pringle, Chris C. T.; Willis, Ashley P.; Kerswell, Rich R.

    A new, fully localised, energy growth optimal is found over large times and in long pipe domains at a given mass flow rate. This optimal emerges at a threshold disturbance energy below which a nonlinear version of the known (streamwise-independent) linear optimal [P. J. Schmid and D. S. Henningson, “Optimal energy density growth in Hagen-Poiseuille flow,” J. Fluid Mech. 277, 192–225 (1994)] is selected and appears to remain the optimal up until the critical energy at which transition is triggered. The form of this optimal is similar to that found in short pipes [Pringle et al., “Minimal seeds for shearmore » flow turbulence: Using nonlinear transient growth to touch the edge of chaos,” J. Fluid Mech. 702, 415–443 (2012)], but now with full localisation in the streamwise direction. This fully localised optimal perturbation represents the best approximation yet of the minimal seed (the smallest perturbation which is arbitrarily close to states capable of triggering a turbulent episode) for “real” (laboratory) pipe flows. Dependence of the optimal with respect to several parameters has been computed and establishes that the structure is robust.« less

  14. Muscarinic receptor M1 and M2 subtypes in the human eye: QNB, pirenzipine, oxotremorine, and AFDX-116 in vitro autoradiography.

    PubMed Central

    Gupta, N; McAllister, R; Drance, S M; Rootman, J; Cynader, M S

    1994-01-01

    Muscarinic cholinergic agents are used to lower intraocular pressure in the medical management of glaucoma and subtypes of muscarinic receptors have now been recognised in many tissues including the eye. To localise muscarinic receptors and their M1 and M2 subtypes in the human eye, in vitro ligand binding and autoradiographic techniques with densitometric quantitation on postmortem eye sections were used. As ligands, [3H] quinuclydinyl benzylate (QNB) (non-subtype specific muscarinic antagonist), [3H]pirenzipine (M1 antagonist), [3H]oxotremorine (M2 muscarinic agonist), [3H]AFDX-116(11[(2[diethylaminomethyl]1-piperidinyl)acetyl]5 , 11dihydro-6H-pyrido [2,3b][1,4]benzodiazepine-6-one) (M2 antagonist) were studied. Specific binding sites for QNB, pirenzipine, and AFDX-116 were localised in the entire ciliary muscle, the iris, and ciliary epithelium. [3H]oxotremorine localised only in the longitudinal portion of the ciliary muscle, and additionally, was not localised in the iris or ciliary epithelium. These results suggest that oxotremorine, by binding selectively to receptors on the longitudinal ciliary muscle and inducing its contraction, may modulate outflow facility independently from accommodation and miosis. Images PMID:7918268

  15. Silicon Carbide Temperature Monitor Processing Improvements. Status Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Unruh, Troy Casey; Daw, Joshua Earl; Ahamad Al Rashdan

    2016-01-29

    Silicon carbide (SiC) temperature monitors are used as temperature sensors in Advanced Test Reactor (ATR) irradiations at the Idaho National Laboratory (INL). Although thermocouples are typically used to provide real-time temperature indication in instrumented lead tests, other indicators, such as melt wires, are also often included in such tests as an independent technique of detecting peak temperatures incurred during irradiation. In addition, less expensive static capsule tests, which have no leads attached for real-time data transmission, often rely on melt wires as a post-irradiation technique for peak temperature indication. Melt wires are limited in that they can only detect whethermore » a single temperature is or is not exceeded. SiC monitors are advantageous because a single monitor can be used to detect for a range of temperatures that occurred during irradiation. As part of the process initiated to make SiC temperature monitors available at the ATR, post-irradiation evaluations of these monitors have been previously completed at the High Temperature Test Laboratory (HTTL). INL selected the resistance measurement approach for determining irradiation temperature from SiC temperature monitors because it is considered to be the most accurate measurement. The current process involves the repeated annealing of the SiC monitors at incrementally increasing temperature, with resistivity measurements made between annealing steps. The process is time consuming and requires the nearly constant attention of a trained staff member. In addition to the expensive and lengthy post analysis required, the current process adds many potential sources of error in the measurement, as the sensor must be repeatedly moved from furnace to test fixture. This time-consuming post irradiation analysis is a significant portion of the total cost of using these otherwise inexpensive sensors. An additional consideration of this research is that, if the SiC post processing can be automated, it could be performed in an MFC hot cell, further reducing the time and expense of lengthy decontaminations prior to processing. Sections of this report provide a general description of resistivity techniques currently used to infer peak irradiation temperature from silicon carbide temperature monitors along with some representative data, the proposed concepts to improve the process of analyzing irradiated SiC temperature monitors, the completed efforts to prove the proposed concepts, and future activities. The efforts detailed here succeeded in designing and developing a real-time automated SiC resistivity measurement system, and performed two initial test runs. Activities carried out include the assembly and integration of the system hardware; the design and development of a preliminary monitor fixture; the design of a technique to automate the data analysis and processing; the development of the communication, coordination, and user software; and the execution and troubleshooting of test run experiments using the box furnace. Although the automation system performed as required, the designed fixture did not succeed in establishing the needed electrical contacts with the SiC monitor.« less

  16. Shaping ability of reciprocating motion of WaveOne and HyFlex in moderate to severe curved canals: A comparative study with cone beam computed tomography

    PubMed Central

    Simpsy, Gurram Samuel; Sajjan, Girija S.; Mudunuri, Padmaja; Chittem, Jyothi; Prasanthi, Nalam N. V. D.; Balaga, Pankaj

    2016-01-01

    Introduction: M-Wire and reciprocating motion of WaveOne and controlled memory (CM) wire) of HyFlex were the recent innovations using thermal treatment. Therefore, a study was planned to evaluate the shaping ability of reciprocating motion of WaveOne and HyFlex using cone beam computed tomography (CBCT). Methodology: Forty-five freshly extracted mandibular teeth were selected and stored in saline until use. All teeth were scanned pre- and post-operatively using CBCT (Kodak 9000). All teeth were accessed and divided into three groups. (1) Group 1 (control n = 15): Instrumented with ProTaper. (2) Group 2 (n = 15): Instrumented with primary file (8%/25) WaveOne. (3) Group 3 (n = 15): Instrumented with (4%/25) HyFlex CM. Sections at 1, 3, and 5 mm were obtained from the pre- and post-operative scans. Measurement was done using CS3D software and Adobe Photoshop software. Apical transportation and degree of straightening were measured and statistically analyzed. Results: HyFlex showed lesser apical transportation when compared to other groups at 1 and 3 mm. WaveOne showed lesser degree of straightening when compared to other groups. Conclusion: This present study concluded that all systems could be employed in routine endodontics whereas HyFlex and WaveOne could be employed in severely curved canals. PMID:27994323

  17. Lithologically controlled invisible gold, Yukon, Canada

    NASA Astrophysics Data System (ADS)

    MacKenzie, Doug; Craw, Dave; Finnigan, Craig

    2015-02-01

    The newly discovered Cretaceous Coffee orogenic gold deposit (>4 Moz resource) consists of an extensive oxidised zone developed on primary sulphidic rock. The primary mineralised rock is characterised by invisible gold in arsenian pyrite that has replaced biotite in selected host rocks. The deposit has a cryptic surface expression and is an example of an extremely subtle exploration target. Hydrothermal emplacement was controlled by extensional fractures, with breccias, but most mineralisation was focused on biotite-bearing granitic gneiss, metasedimentary gneisses, and younger biotite granite. Fine-grained (<0.1 mm) arsenian pyrite replaced biotite along mineral cleavage planes and followed biotite-rich metamorphic and post-metamorphic structural fabrics. Arsenian pyrite also formed overgrowths on earlier coarse-grained (up to 2 mm) barren hydrothermal pyrite. Arsenian pyrite is concentrically zoned on the 1-10-μm scale with respect to As, Sb, and Au contents and typically contains ˜5 wt% As, ˜500 mg/kg Sb, and ˜500 mg/kg Au, in solid solution. Biotite replacement was accompanied by sericitisation, silicification, and ankerite impregnation. Hydrothermal alteration involved dilution and localised depletion of K, Na, and Al in silicified host rocks, but most Ca, Mg, and Fe concentrations remained broadly constant. Magnesium-rich ultramafic host rocks were only weakly mineralised with auriferous arsenian pyrite and have fuchsite and magnesite alteration. Near-surface oxidation has liberated nanoparticulate and microparticulate supergene gold, which remains essentially invisible. Varying degrees of oxidation extend as deep as 250 m below the present subdued topographic surface, well beyond the present vadose zone, and this deep oxidation may have occurred during post-mineralisation uplift and erosion in the Cretaceous. Oxidation has leached some As from the surficial mineralised rocks, decreasing the geochemical signal, which is also obscured by the localised presence of high background As (up to 100 mg/kg) in metasedimentary quartzites in the region. Antimony provides more reliable soil anomalies than As, but most Sb anomalies are <100 mg/kg. The persistence of invisible gold into the extensive supergene zone, with little gold particle size enhancement, has ensured that no placer deposits have formed in nearby streams, further restricting the surface footprint and Au dispersal halo of this subtle exploration target.

  18. Pharmacologic modulation of protein kinase C isozymes: the role of RACKs and subcellular localisation.

    PubMed

    Csukai, M; Mochly-Rosen, D

    1999-04-01

    Protein kinase C (PKC) isozymes are highly homologous kinases and several different isozymes can be present in a cell. Each isozyme is likely to mediate unique functions, but pharmacological tools to explore their isozyme-specific roles have not been available until recently. In this review, we describe the development and application of isozyme-selective inhibitors of PKC. The identification of these inhibitors stems from the observation that PKC isozymes are each localised to unique subcellular locations following activation. Inhibitors of this isozyme-unique localisation have been shown to act as selective inhibitors of the functions of individual isozymes. The identification of isozyme-specific inhibitors should allow the exploration of individual PKC isozyme function in a wide range of cell systems. Copyright 1999 The Italian Pharmacological Society.

  19. Is 20 years of immobilization, not sufficient to render metacarpophalangeal joints completely useless?--Correction of a 20-year old post-burn palmar contracture: a case report.

    PubMed

    Saraiya, H

    2001-03-01

    This report presents a case of post-burn palmar contracture with flexion contracture of thumb of 20-year duration. The contracture was released and the raw area was covered with split thickness skin graft. Only one 'K' wire in soft tissue was needed to keep all the fingers straight and immobilized, suggestive of intermetacarpal ligamentous contracture. A static night splint was given to maintain the correction. Complete range of movement was achieved in a month with the combination of dynamic splinting and physiotherapy. It was interesting to note that even 20 years of contracted position did not render the metacarpophalangeal joints completely stiff and useless. Probable reasons are discussed.

  20. 30 CFR 77.1802 - Insulation of trolley wires, trolley feeder wires and bare signal wires; guarding of trolley...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Insulation of trolley wires, trolley feeder wires and bare signal wires; guarding of trolley wires and trolley feeder wires. 77.1802 Section 77.1802... Wires and Trolley Feeder Wires § 77.1802 Insulation of trolley wires, trolley feeder wires and bare...

  1. 30 CFR 77.1802 - Insulation of trolley wires, trolley feeder wires and bare signal wires; guarding of trolley...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Insulation of trolley wires, trolley feeder wires and bare signal wires; guarding of trolley wires and trolley feeder wires. 77.1802 Section 77.1802... Wires and Trolley Feeder Wires § 77.1802 Insulation of trolley wires, trolley feeder wires and bare...

  2. To localise or to be localised with WiFi in the Hubei museum?

    NASA Astrophysics Data System (ADS)

    Verbree, E.; Zlatanova, S.; van Winden, K. B. A.; van der Laan, E. B.; Makri, A.; Taizhou, L.; Haojun, A.

    2013-11-01

    Indoor localisation is in demand for a variety of applications within the built environment. An overall solution based on a single technology has not yet been determined. The aim of this paper is to gain insight on Signal Strength monitoring by a special kind of WiFi Monitors in comparison to the commonly known fingerprinting method for the purpose of a 3D indoor navigation system. Ttwo different WiFi based localisation techniques are tested during the MSc Geomatics DaRen Syntheses Project in the Hubei Provincial Museum, China. The first method detects the beacon frames send by smartphones, laptops and other WiFi enabled devices in range using Libelium Meshlium Xtreme monitors. Their MAC addresses and the signal strength is measured by the Meshlium Xtreme and stored on an external database. We call this method WiFi monitoring. The second method a Wifi enabled device, like a smartphone, measures the signal strength of multiple Wifi Access Points in range to localise itself based on a previously created radio map. This method is known as WiFi fingerprinting. Both methods have some advantages and disadvantages. Advantages of the common way of WiFi fingerprinting are that the implementation costs are relatively low, because it is usually possible to use (a part of) the existing WiFi AP infrastructure. WiFi fingerprinting can reach a relatively high accuracy in the order of magnitude of meters. Finally, the location granularity can be adjusted to what is necessary for the purpose of the indoor localisation. This makes it employable for a wide range of purposes. The question remains how suitable these methods are for a 3D indoor navigation system for the Hubei provincial museum. One important aspect is the localisation-granularity necessary for the application. In a museum it is not necessary to know the exact X,Y position of a user (such high accuracy is unnecessary), more important is to know in which room the user is located so the information on exhibitions can be presented and the starting point of the navigation can be determined. Both methods can track the user and tell the room he or she is located at. Although WiFi smartphone monitoring may have a low update frequency it is still suitable for a navigation system for a museum since visitors usually spend more than a couple of minutes within a room.

  3. Inhibiting the phosphatidylinositide 3-kinase pathway blocks radiation-induced metastasis associated with Rho-GTPase and Hypoxia-inducible factor-1 activity.

    PubMed

    Burrows, Natalie; Telfer, Brian; Brabant, Georg; Williams, Kaye J

    2013-09-01

    Undifferentiated follicular and anaplastic thyroid tumours often respond poorly to radiotherapy and show increased metastatic potential. We evaluated radiation-induced effects on metastasis in thyroid carcinoma cells and tumours, mechanistically focusing on phosphatidylinositide 3-kinase (PI3K) and associated pathways. Migration was analysed in follicular (FTC133) and anaplastic (8505c) cells following radiotherapy (0-6 Gray) with concomitant pharmacological (GDC-0941) or genetic inhibition of PI3K. Hypoxia-inducible factor-1 (HIF-1)-activity was measured using luciferase reporter assays and was inhibited using a dominant-negative variant. Activation and subcellular localisation of target proteins were assessed via Western blot and immunofluorescence. In vivo studies used FTC133 xenografts with metastatic lung dissemination assessed ex vivo. Radiation induced migration in a HIF-dependent manner in FTC133 cells but decreased migration in 8505c's. Post-radiation HIF-activity correlated with migratory phenotype. PI3K-targeting inhibited migration under basal and irradiated conditions through inhibition of HIF-1α, Rho-GTPase expression/activity and localisation whilst having little effect on src/FAK. In vivo, radiation induced PI3K, HIF, Rho-GTPases and src but only PI3K, HIF and Rho-GTPases were inhibited by GDC-0941. Co-treatment with GDC-0941 and radiation significantly reduced metastatic dissemination versus radiotherapy alone. Radiation modifies metastatic characteristics of thyroid carcinoma cells, which can be successfully inhibited by targeting PI3K using GDC-0941 in vitro and in vivo. Copyright © 2013 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.

  4. Full-field Measurements of Strain Localisation in Sandstone by Neutron Tomography and 3D-Volumetric Digital Image Correlation

    NASA Astrophysics Data System (ADS)

    Tudisco, E.; Hall, S. A.; Charalampidou, E. M.; Kardjilov, N.; Hilger, A.; Sone, H.

    Recent studies have demonstrated that the combination of x-ray tomography during triaxial tests (;in-situ; tests) and 3D- volumetric Digital Image Correlation (3D-DIC) can provide important insight into the mechanical behaviour and deformation processes of granular materials such as sand. The application of these tools to investigate the mechanisms of failure in rocks is also of obvious interest. However, the relevant applied confining pressures for triaxial testing on rocks are higher than those on sands and therefore stronger pressure containment vessels, i.e., made of thick metal walls, are required. This makes in-situ x-ray imaging of rock deformation during triaxial tests a challenge. One possible solution to overcome this problem is to use neutrons, which should better penetrate the metal-walls of the pressure vessels. In this perspective, this work assesses the capability of neutron tomography with 3D-DIC to measure deformation fields in rock samples. Results from pre- and post-deformation neutron tomography of a Bentheim sandstone sample deformed ex-situ at 40 MPa show that clear images of the internal structure can be achieved and utilised for 3D-DIC analysis to reveal the details of the 3D strain field. From these results the character of the localised deformation in the study sample can thus be described. Furthermore, comparison with analyses based on equivalent x-ray tomography imaging of the same sample confirms the effectiveness of the method in relation to the more established x-ray based approach.

  5. Effect of season on peripheral resistance to localised cold stress

    NASA Astrophysics Data System (ADS)

    Tanaka, M.; Harimura, Y.; Tochihara, Y.; Yamazaki, S.; Ohnaka, T.; Matsui, J.; Yoshida, K.

    1984-03-01

    This study was carried out to determine the effect that seasonal changes have on the effect of localised cold stress on peripheral temperatures using the foot immersion method with a cold water bath. The subjects were six males and four females. The data were obtained in April, July, October and January. Skin temperature of the right index finger, the forehead, the arm, the cheek, the second toe and the instep were measured before, during and after the immersion of the feet in water at 15°C for 10 mins, as well as oxygen consumption before immersion of the feet. The average finger temperature was highest during foot immersion in the summer, next highest in the winter, then spring, and the lowest during foot immersion in the autumn. The finger temperatures during the pre-immersion period in the autumn tended to be lower than in other seasons. The finger temperatures during the pre-immersion period affected the temperature change of the finger during the immersion period. The rate of increase of the toe temperature and the foot temperature during post-immersion in the summer and the spring were greater than those in the autumn and winter. Oxygen consumption during the pre-immersion period in the autumn was significantly lower than in the other seasons (p<0.001 or 0.010). Cooling the feet caused no significant changes in the temperatures the cheek, forehead or forearm. The cheek temperature in the summer and autumn was cooler than corresponding temperatures taken in the winter and spring.

  6. Wire Insulation Flammability Experiment: USML-1 One Year Post Mission Summary

    NASA Technical Reports Server (NTRS)

    Greenberg, Paul S.; Sacksteder, Kurt R.; Kashiwagi, Takashi

    1994-01-01

    Herein we report the results from the Wire Insulation Flammability (WIF) Experiment performed in the Glovebox Facility on the USML-1 mission. This experiment explored various aspects of electrically induced fire scenarios in a reduced gravity environment. Under quiescent microgravity conditions, heat and mass transfer are dominated by diffusive and radiative transport; while in normal-gravity buoyancy induced convection often dominates. Of considerable scientific and practical interest is the intermediate situation of combustion occurring in the presence of imposed gas flows, with lower characteristic velocities than those induced by buoyancy in noma1 gravity. Two distinct cases naturally arise: flow direction opposed to, or concurrent with, the flame spread direction. Two tests of each kind were conducted in the WIF experiment, providing the first controlled demonstration of flame spreading in forced convection ever conducted in space. Four test modules were flown. The wire insulation, 1.5 mm in diameter, was polyethylene, extruded onto nichrome wire. Temperatures of the wh3 cores and insulation heated in quiescent and flowing environments were measured. Video and still-camera images of the samples, burning in air flowing at approximately 10 cm/sec, were recorded to obtain flame characteristics including spread rate, structure and temperature. Flame spread rates in concurrent flow were approximately twice those in opposed flow. In concurrent and opposed flow regimes, the spreading flames stabilized around a bead of molten insulation material, within which bubble nucleation was observed. An ignition attempt without flow mated a quiescent cloud of vaporized fuel which ignited dramatically yet failed to sustain normal flame spread. Finally, all tests produced substantial soot agglomerates, particularly the concurrent flow tests; and the collected soot has a morphology very distinct from soot formed in normal gravity flames. Several unexpected and unique microgravity combustion phenomena were observed.

  7. Cyclic fatigue resistance of a novel rotary file manufactured using controlled memory Ni-Ti technology compared to a file made from M-wire file.

    PubMed

    AlShwaimi, E

    2018-01-01

    To compare the cyclic fatigue properties of a novel file made using controlled memory Ni-Ti technology with those of files made from M-wire. Twelve files with similar cross-sectional geometry and tip size from each of the following groups were tested: Proflexendo made from CMT (PE; size 30 0.04; Nexden, Houston, Tx, USA), ProFile Vortex made from M-wire (PV; size 30 0.04; Dentsply Tulsa Dental, Tulsa, OK, USA) and ProTaper Universal made from regular alloy (PU; F3; Dentsply Tulsa Dental). A custom-made cyclic fatigue device was made to evaluate the total number of cycles to failure for each system. A scanning electron microscope (SEM) was used to examine the fractured surfaces of the fragments. The arithmetic means and standard deviations were calculated for the total number of cycles to failure. One-way analysis of variance was used to compare the mean cyclic failure amongst the three groups. Post hoc Tukey's test was performed to compare the difference of the means between the groups at a significance level of P < 0.05. Proflexendo had a significantly greater resistance to cyclic fatigue compared to other systems (P < 0.001). Proflexendo files were able to withstand 500% more cycles to fracture when compared to ProFile Vortex files. Manufacturing technique had a significant impact on the resistance to cyclic fatigue. Proflexendo files made from controlled memory Ni-Ti technology had the highest number of cycles to failure compared to ProFile Vortex made from M-wire files with similar taper and tip size. © 2017 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  8. Case reports - When bronchial obstruction in the young adult is not asthma and inhalers do not help.

    PubMed

    Sigvard, Anne; Bødtger, Uffe

    2016-08-01

    Localised bronchial obstruction is a rare differential diagnosis to asthma. We describe two younger patients treated unsuccessfully for asthma and eventually diagnosed with localised bronchoconstriction. Bronchoscopy revealed bronchoconstriction: Tracheobronchomalacia in case 1 and fixed obstruction in case 2. A systematic approach to the asthma patient with absent response to therapy facilitates rational use of therapeutic and diagnostic resources.

  9. Game Localisation as Software-Mediated Cultural Experience: Shedding Light on the Changing Role of Translation in Intercultural Communication in the Digital Age

    ERIC Educational Resources Information Center

    O'Hagan, Minako

    2015-01-01

    In this rapidly technologising age translation practice has been undergoing formidable changes with the implication that there is a need to expand the disciplinary scope of translation studies. Taking the case of game localisation this article problematises the role of translation as intercultural communication by focusing on cultural elements of…

  10. Challenges to Globalisation, Localisation and Sinophilia in Music Education: A Comparative Study of Hong Kong, Shanghai and Taipei

    ERIC Educational Resources Information Center

    Ho, Wai-Chung; Law, Wing-Wah

    2006-01-01

    In the past, the music curricula of Hong Kong (HK), Mainland China and Taiwan have focused on Western music, but with the advent of music technology and the new tripartite paradigm of globalisation, localisation and Sinophilia this has begun to change. Hong Kong, Shanghai and Taipei share a common historical culture and their populations are…

  11. High-Intensity Focused Ultrasound for the Treatment of Localized and Locally Advanced Hormone-Resistant Prostate Cancer: 2,5 Year Outcome

    NASA Astrophysics Data System (ADS)

    Solovov, V. A.; Dvoynikov, S. Y.; Vozdvizhenskiy, M. O.

    2011-09-01

    Introduction & Objectives: High-Intensity Focused Ultrasound (HIFU) has been shown to be a successful treatment for localised prostate cancer (PC). Here we have explored the effectiveness of the HIFU treatment for hormone-resistant prostate cancer (HRPC). Materials & Methods: 341 patients were treated in our center between September 2007 and December 2009; all of them showed treatment failure following hormone ablation. The median time before hormone-resistance was 20 (3-48) months. In the group with localised PC: number of patients 237, Gleason score ≤7, stage T1-2N0M0, age 69 (60-89) years, mean PSA before treatment 40,0 (5,8-92,9) ng/ml, mean prostate volume—39,3 (28-92) cc; in the group with locally advanced PC: number of patients 104, Gleason score ≤9, stage T2-3N0M0, age 72 (52-83) years, PSA before treatment 30,3 (20,1-60) ng/ml, mean prostate volume—41,2 (25-198) cc. HIFU was delivered under spinal anesthesia using the Ablatherm HIFU device (EDAP, France). Pre HIFU transurethral resection of the prostate (TURP) was performed for all patients. Mean follow-up time 18 months (3-30). Results: The median PSA level 12 months after HIFU treatment was 0,04 (0-2,24) ng/ml—localised PC, and for locally advanced disease—0,05 (0-48,4) ng/ml, at 18 months after HIFU treatment this was 0,2 (0,02-2,0) ng/ml for localised PC, and for locally advanced disease 0,18 (0,04-7,45) ng/ml. Patients with localised PC has 4,5% recurrence, those with locally advanced PC 20%. Kaplan-Meir analyses of the total group indicated that the risk of recurrence after 1 year follow-up was 10%, the risk of recurrence was 19% after 2 years of follow-up. Conclusions: Our initial experience shows that ultrasound ablation is safe, minimally invasive and effective as a treatment for localised and locally advanced hormone-resistant prostate cancer.

  12. Automaticity and localisation of concurrents predicts colour area activity in grapheme-colour synaesthesia.

    PubMed

    Gould van Praag, Cassandra D; Garfinkel, Sarah; Ward, Jamie; Bor, Daniel; Seth, Anil K

    2016-07-29

    In grapheme-colour synaesthesia (GCS), the presentation of letters or numbers induces an additional 'concurrent' experience of colour. Early functional MRI (fMRI) investigations of GCS reported activation in colour-selective area V4 during the concurrent experience. However, others have failed to replicate this key finding. We reasoned that individual differences in synaesthetic phenomenology might explain this inconsistency in the literature. To test this hypothesis, we examined fMRI BOLD responses in a group of grapheme-colour synaesthetes (n=20) and matched controls (n=20) while characterising the individual phenomenology of the synaesthetes along dimensions of 'automaticity' and 'localisation'. We used an independent functional localiser to identify colour-selective areas in both groups. Activations in these areas were then assessed during achromatic synaesthesia-inducing, and non-inducing conditions; we also explored whole brain activations, where we sought to replicate the existing literature regarding synaesthesia effects. Controls showed no significant activations in the contrast of inducing > non-inducing synaesthetic stimuli, in colour-selective ROIs or at the whole brain level. In the synaesthete group, we correlated activation within colour-selective ROIs with individual differences in phenomenology using the Coloured Letters and Numbers (CLaN) questionnaire which measures, amongst other attributes, the subjective automaticity/attention in synaesthetic concurrents, and their spatial localisation. Supporting our hypothesis, we found significant correlations between individual measures of synaesthetic phenomenology and BOLD responses in colour-selective areas, when contrasting inducing against non-inducing stimuli. Specifically, left-hemisphere colour area responses were stronger for synaesthetes scoring high on phenomenological localisation and automaticity/attention, while right-hemisphere colour area responses showed a relationship with localisation only. In exploratory whole brain analyses, the BOLD response within several other areas was also correlated with these phenomenological factors, including the intra-parietal sulcus, insula, precentral and supplementary motor areas. Our findings reveal a network of regions underlying synaesthetic phenomenology and they help reconcile the diversity of previous results regarding colour-selective BOLD responses during synaesthesia, by establishing a bridge between neural responses and individual synaesthetic phenomenology. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  13. Tissue Inhibitor of Metalloproteinase-3 (TIMP-3) induces FAS dependent apoptosis in human vascular smooth muscle cells.

    PubMed

    English, William R; Ireland-Zecchini, Heather; Baker, Andrew H; Littlewood, Trevor D; Bennett, Martin R; Murphy, Gillian

    2018-01-01

    Over expression of Tissue Inhibitor of Metalloproteinases-3 (TIMP-3) in vascular smooth muscle cells (VSMCs) induces apoptosis and reduces neointima formation occurring after saphenous vein interposition grafting or coronary stenting. In studies to address the mechanism of TIMP-3-driven apoptosis in human VSMCs we find that TIMP-3 increased activation of caspase-8 and apoptosis was inhibited by expression of Cytokine response modifier A (CrmA) and dominant negative FAS-Associated protein with Death Domain (FADD). TIMP-3 induced apoptosis did not cause mitochondrial depolarisation, increase activation of caspase-9 and was not inhibited by over-expression of B-cell Lymphoma 2 (Bcl2), indicating a mitochondrial independent/type-I death receptor pathway. TIMP-3 increased levels of the First Apoptosis Signal receptor (FAS) and depletion of FAS with shRNA showed TIMP-3-induced apoptosis was FAS dependent. TIMP-3 induced formation of the Death-Inducing Signalling Complex (DISC), as detected by immunoprecipitation and by immunofluorescence. Cellular-FADD-like IL-1 converting enzyme-Like Inhibitory Protein (c-FLIP) localised with FAS at the cell periphery in the absence of TIMP-3 and this localisation was lost on TIMP-3 expression with c-FLIP adopting a perinuclear localisation. Although TIMP-3 inhibited FAS shedding, this did not increase total surface levels of FAS but instead increased FAS levels within localised regions at the cell surface. A Disintegrin And Metalloproteinase 17 (ADAM17) is inhibited by TIMP-3 and depletion of ADAM17 with shRNA significantly decreased FAS shedding. However ADAM17 depletion did not induce apoptosis or replicate the effects of TIMP-3 by increasing localised clustering of cell surface FAS. ADAM17-depleted cells could activate caspase-3 when expressing levels of TIMP-3 that were otherwise sub-apoptotic, suggesting a partial role for ADAM17 mediated ectodomain shedding in TIMP-3 mediated apoptosis. We conclude that TIMP-3 induced apoptosis in VSMCs is highly dependent on FAS and is associated with changes in FAS and c-FLIP localisation, but is not solely dependent on shedding of the FAS ectodomain.

  14. Tissue Inhibitor of Metalloproteinase–3 (TIMP-3) induces FAS dependent apoptosis in human vascular smooth muscle cells

    PubMed Central

    Ireland-Zecchini, Heather; Baker, Andrew H.; Littlewood, Trevor D.; Bennett, Martin R.; Murphy, Gillian

    2018-01-01

    Over expression of Tissue Inhibitor of Metalloproteinases-3 (TIMP-3) in vascular smooth muscle cells (VSMCs) induces apoptosis and reduces neointima formation occurring after saphenous vein interposition grafting or coronary stenting. In studies to address the mechanism of TIMP-3-driven apoptosis in human VSMCs we find that TIMP-3 increased activation of caspase-8 and apoptosis was inhibited by expression of Cytokine response modifier A (CrmA) and dominant negative FAS-Associated protein with Death Domain (FADD). TIMP-3 induced apoptosis did not cause mitochondrial depolarisation, increase activation of caspase-9 and was not inhibited by over-expression of B-cell Lymphoma 2 (Bcl2), indicating a mitochondrial independent/type-I death receptor pathway. TIMP-3 increased levels of the First Apoptosis Signal receptor (FAS) and depletion of FAS with shRNA showed TIMP-3-induced apoptosis was FAS dependent. TIMP-3 induced formation of the Death-Inducing Signalling Complex (DISC), as detected by immunoprecipitation and by immunofluorescence. Cellular-FADD-like IL-1 converting enzyme-Like Inhibitory Protein (c-FLIP) localised with FAS at the cell periphery in the absence of TIMP-3 and this localisation was lost on TIMP-3 expression with c-FLIP adopting a perinuclear localisation. Although TIMP-3 inhibited FAS shedding, this did not increase total surface levels of FAS but instead increased FAS levels within localised regions at the cell surface. A Disintegrin And Metalloproteinase 17 (ADAM17) is inhibited by TIMP-3 and depletion of ADAM17 with shRNA significantly decreased FAS shedding. However ADAM17 depletion did not induce apoptosis or replicate the effects of TIMP-3 by increasing localised clustering of cell surface FAS. ADAM17-depleted cells could activate caspase-3 when expressing levels of TIMP-3 that were otherwise sub-apoptotic, suggesting a partial role for ADAM17 mediated ectodomain shedding in TIMP-3 mediated apoptosis. We conclude that TIMP-3 induced apoptosis in VSMCs is highly dependent on FAS and is associated with changes in FAS and c-FLIP localisation, but is not solely dependent on shedding of the FAS ectodomain. PMID:29617412

  15. 18F-FDG PET and PET/CT in the Localization and Characterization of Lesions in Patients with Ovarian Cancer.

    PubMed

    Caprio, M G; Capacchione, D; Mainolfi, C; Spera, A M; Salvatore, B; Cella, L; Salvatore, M; Pace, L

    2012-01-01

    The aim was to compare the imaging findings of (18)F-fluorodeoxyglucose ((18)F-FDG) PET and integrated PET/CT in patients with primary, recurrent or metastatic ovarian cancer. 21 women with ovarian cancer were evaluated. All patients had a integrated PET/CT scan. Localization, infiltration and uptake intensity of [(18)F]FDG were evaluated on PET and PET/CT. The certainty of localisation and characterisation was scored on a 3 point scale (L1 definite localisation; L2 probable localisation; L3 uncertain localisation; C1 benign; C2 equivocal; C3 malignant). PET scored as L1 54 lesions (44%), as L2 51 (42%), and as L3 17 (14%). On the other hand, PET/CT scored as L1 120 lesions (98%), as L2 2 (2%), and none as L3. Thus PET/CT allowed a better localization in 54% of lesions. Moreover, PET scored as C1 25 lesions (20%), as C2 62 (51%), and as C3 35 (29%). On the other hand, PET/CT scored as C1 57 lesions (47%), as C2 13 (11%), and as C3 52 (42%). Thus PET/CT allowed a sensible reduction in the number of equivocal lesions (40%). Even when patients were subgrouped on the basis of clinical stage of the disease, PET/CT was capable of better definition of the lesions either for localization and for characterization. In patients with ovarian cancer, PET/CT allows better anatomical localisation of pathologic uptake providing high accuracy for staging and restaging of ovarian cancer when compared with PET alone.

  16. Comparison of 68Ga-DOTANOC PET/CT and contrast-enhanced CT in localisation of tumours in ectopic ACTH syndrome

    PubMed Central

    Jadhav, Swati S; Lila, Anurag R; Kasaliwal, Rajeev; Khare, Shruti; Yerawar, Chaitanya G; Hira, Priya; Phadke, Uday; Shah, Hina; Lele, Vikram R; Malhotra, Gaurav; Bandgar, Tushar; Shah, Nalini S

    2016-01-01

    Background Localising ectopic adrenocorticotrophic hormone (ACTH) syndrome (EAS) tumour source is challenging. Somatostatin receptor-based PET imaging has shown promising results, but the data is limited to case reports and small case series. We reviewed here the performance of 68Ga-DOTANOC positron emission tomography (PET)/computed tomography (CT) and contrast-enhanced CT (CECT) in our cohort of 12 consecutive EAS patients. Materials and methods Retrospective data analysis of 12 consecutive patients of EAS presenting to a single tertiary care centre in a period between January 2013 and December 2014 was done. CECT and 68Ga-DOTANOC PET/CT were reported (blinded) by an experienced radiologist and a nuclear medicine physician, respectively. The performance of CECT and 68Ga-DOTANOC PET/CT was compared. Results Tumours could be localised in 11 out of 12 patients at initial presentation (overt cases), whereas in one patient, tumour remained occult. Thirteen lesions were identified in 11 patients as EAS source (true positives). CECT localised 12 out of these 13 lesions (sensitivity 92.3%) and identified five false-positive lesions (positive predictive value (PPV) 70.5%). Compared with false-positive lesions, true-positive lesions had greater mean contrast enhancement at 60s (33.2 vs 5.6 Hounsfield units (HU)). 68Ga-DOTANOC PET/CT was able to identify 9 out of 13 lesions (sensitivity 69.2%) and reported no false-positive lesions (PPV 100%). Conclusion CECT remains the first-line investigation in localisation of EAS. The contrast enhancement pattern on CECT can further aid in characterisation of the lesions. 68Ga-DOTANOC PET/CT can be added to CECT, to enhance positive prediction of the suggestive lesions. PMID:27006371

  17. Localised hyperthermia in rodent models using an MRI-compatible high-intensity focused ultrasound system

    PubMed Central

    Bing, Chenchen; Nofiele, Joris; Staruch, Robert; Ladouceur-Wodzak, Michelle; Chatzinoff, Yonatan; Ranjan, Ashish; Chopra, Rajiv

    2015-01-01

    Purpose Localised hyperthermia in rodent studies is challenging due to the small target size. This study describes the development and characterisation of an MRI-compatible high-intensity focused ultrasound (HIFU) system to perform localised mild hyperthermia treatments in rodent models. Material and methods The hyperthermia platform consisted of an MRI-compatible small animal HIFU system, focused transducers with sector-vortex lenses, a custom-made receive coil, and means to maintain systemic temperatures of rodents. The system was integrated into a 3T MR imager. Control software was developed to acquire images, process temperature maps, and adjust output power using a proportional-integral-derivative feedback control algorithm. Hyperthermia exposures were performed in tissue-mimicking phantoms and in a rodent model (n = 9). During heating, an ROI was assigned in the heated region for temperature control and the target temperature was 42 °C; 30 min mild hyperthermia treatment followed by a 10-min cooling procedure was performed on each animal. Results 3D-printed sector-vortex lenses were successful at creating annular focal regions which enables customisation of the heating volume. Localised mild hyperthermia performed in rats produced a mean ROI temperature of 42.1 ± 0.3 °C. The T10 and T90 percentiles were 43.2 ± 0.4 °C and 41.0 ± 0.3 °C, respectively. For a 30-min treatment, the mean time duration between 41–45 °C was 31.1 min within the ROI. Conclusions The MRI-compatible HIFU system was successfully adapted to perform localised mild hyperthermia treatment in rodent models. A target temperature of 42 °C was well-maintained in a rat thigh model for 30 min. PMID:26540488

  18. A discussion on the merits and limitations of using drive-by monitoring to detect localised damage in a bridge

    NASA Astrophysics Data System (ADS)

    Hester, David; González, Arturo

    2017-06-01

    Given the large number of bridges that currently have no instrumentation, there are obvious advantages in monitoring the condition of a bridge by analysing the response of a vehicle crossing it. As a result, the last two decades have seen a rise in the research attempting to solve the problem of identifying damage in a bridge from vehicle measurements. This paper examines the theoretical feasibility and practical limitations of a drive-by system in identifying damage associated to localised stiffness losses. First, the nature of the damage feature that is sought within the vehicle response needs to be characterized. For this purpose, the total vehicle response is considered to be made of 'static' and 'dynamic' components, and where the bridge has experienced a localised loss in stiffness, an additional 'damage' component. Understanding the nature of this 'damage' component is crucial to have an informed discussion on how damage can be identified and localised. Leveraging this new understanding, the authors propose a wavelet-based drive-by algorithm. By comparing the effect of the 'damage' component to other key effects defining the measurements such as 'vehicle speed', the 'road profile' and 'noise' on a wavelet contour plot, it is possible to establish if there is a frequency range where drive-by can be successful. The algorithm uses then specific frequency bands to improve the sensitivity to damage with respect to limitations imposed by Vehicle-Bridge vibrations. Recommendations on the selection of the mother wavelet and frequency band are provided. Finally, the paper discusses the impact of noise and road profile on the ability of the approach to identify damage and how periodic measurements can be effective at monitoring localised stiffness changes.

  19. Non-orthogonal tool/flange and robot/world calibration.

    PubMed

    Ernst, Floris; Richter, Lars; Matthäus, Lars; Martens, Volker; Bruder, Ralf; Schlaefer, Alexander; Schweikard, Achim

    2012-12-01

    For many robot-assisted medical applications, it is necessary to accurately compute the relation between the robot's coordinate system and the coordinate system of a localisation or tracking device. Today, this is typically carried out using hand-eye calibration methods like those proposed by Tsai/Lenz or Daniilidis. We present a new method for simultaneous tool/flange and robot/world calibration by estimating a solution to the matrix equation AX = YB. It is computed using a least-squares approach. Because real robots and localisation are all afflicted by errors, our approach allows for non-orthogonal matrices, partially compensating for imperfect calibration of the robot or localisation device. We also introduce a new method where full robot/world and partial tool/flange calibration is possible by using localisation devices providing less than six degrees of freedom (DOFs). The methods are evaluated on simulation data and on real-world measurements from optical and magnetical tracking devices, volumetric ultrasound providing 3-DOF data, and a surface laser scanning device. We compare our methods with two classical approaches: the method by Tsai/Lenz and the method by Daniilidis. In all experiments, the new algorithms outperform the classical methods in terms of translational accuracy by up to 80% and perform similarly in terms of rotational accuracy. Additionally, the methods are shown to be stable: the number of calibration stations used has far less influence on calibration quality than for the classical methods. Our work shows that the new method can be used for estimating the relationship between the robot's and the localisation device's coordinate systems. The new method can also be used for deficient systems providing only 3-DOF data, and it can be employed in real-time scenarios because of its speed. Copyright © 2012 John Wiley & Sons, Ltd.

  20. Hearing aid fitting for visual and hearing impaired patients with Usher syndrome type IIa.

    PubMed

    Hartel, B P; Agterberg, M J H; Snik, A F; Kunst, H P M; van Opstal, A J; Bosman, A J; Pennings, R J E

    2017-08-01

    Usher syndrome is the leading cause of hereditary deaf-blindness. Most patients with Usher syndrome type IIa start using hearing aids from a young age. A serious complaint refers to interference between sound localisation abilities and adaptive sound processing (compression), as present in today's hearing aids. The aim of this study was to investigate the effect of advanced signal processing on binaural hearing, including sound localisation. In this prospective study, patients were fitted with hearing aids with a nonlinear (compression) and linear amplification programs. Data logging was used to objectively evaluate the use of either program. Performance was evaluated with a speech-in-noise test, a sound localisation test and two questionnaires focussing on self-reported benefit. Data logging confirmed that the reported use of hearing aids was high. The linear program was used significantly more often (average use: 77%) than the nonlinear program (average use: 17%). The results for speech intelligibility in noise and sound localisation did not show a significant difference between type of amplification. However, the self-reported outcomes showed higher scores on 'ease of communication' and overall benefit, and significant lower scores on disability for the new hearing aids when compared to their previous hearing aids with compression amplification. Patients with Usher syndrome type IIa prefer a linear amplification over nonlinear amplification when fitted with novel hearing aids. Apart from a significantly higher logged use, no difference in speech in noise and sound localisation was observed between linear and nonlinear amplification with the currently used tests. Further research is needed to evaluate the reasons behind the preference for the linear settings. © 2016 The Authors. Clinical Otolaryngology Published by John Wiley & Sons Ltd.

  1. Evolution of the localisation and composition of phenolics in grape skin between veraison and maturity in relation to water availability and some climatic conditions.

    PubMed

    Cadot, Yves; Chevalier, Michel; Barbeau, Gerard

    2011-08-30

    Several studies have investigated the composition of phenolics in grape skin during grape maturation under various conditions of light exposure, water stress, nitrogen supply and mineral nutrition, but their localisation during berry development is not well known. In this study the composition and localisation of proanthocyanidins were monitored for three years on four plots known to induce a distinctive behaviour of the vine (Cabernet Franc). The composition of phenolics was determined by spectrophotometry; also, in one year, proanthocyanidins were determined by high-performance liquid chromatography. Further information was obtained histochemically by means of toluidine blue O staining and image analysis. The results indicated that clear differences in phenolic quantification existed between the biochemical and histochemical approaches; the proportion of cells without phenolics was not linked with the quantity determined by the analytical methods used. The histochemical method showed the evolution of the localisation and typology of cells with and without phenolics during ripening. The number of cells without any phenolic compounds appeared to be very dependent on the mesoclimatic conditions and only slightly dependent on the site water status. Clear differences in phenolic quantification existed between the biochemical and histochemical approaches; the proportion of cells with phenolics was not linked with the quantity determined by biochemistry. The histochemical method showed an evolution of the localisation and typology of cells with and without phenolics in which mesoclimatic conditions were the most influential factor. Finally, the study showed some advantages of the histochemical approach: it gives information about the anatomy of the tissue as well as the nature and distribution of some of the large macromolecules and allows reconstruction of the three-dimensional plant structure. Copyright © 2011 Society of Chemical Industry.

  2. Novel maximum likelihood approach for passive detection and localisation of multiple emitters

    NASA Astrophysics Data System (ADS)

    Hernandez, Marcel

    2017-12-01

    In this paper, a novel target acquisition and localisation algorithm (TALA) is introduced that offers a capability for detecting and localising multiple targets using the intermittent "signals-of-opportunity" (e.g. acoustic impulses or radio frequency transmissions) they generate. The TALA is a batch estimator that addresses the complex multi-sensor/multi-target data association problem in order to estimate the locations of an unknown number of targets. The TALA is unique in that it does not require measurements to be of a specific type, and can be implemented for systems composed of either homogeneous or heterogeneous sensors. The performance of the TALA is demonstrated in simulated scenarios with a network of 20 sensors and up to 10 targets. The sensors generate angle-of-arrival (AOA), time-of-arrival (TOA), or hybrid AOA/TOA measurements. It is shown that the TALA is able to successfully detect 83-99% of the targets, with a negligible number of false targets declared. Furthermore, the localisation errors of the TALA are typically within 10% of the errors generated by a "genie" algorithm that is given the correct measurement-to-target associations. The TALA also performs well in comparison with an optimistic Cramér-Rao lower bound, with typical differences in performance of 10-20%, and differences in performance of 40-50% in the most difficult scenarios considered. The computational expense of the TALA is also controllable, which allows the TALA to maintain computational feasibility even in the most challenging scenarios considered. This allows the approach to be implemented in time-critical scenarios, such as in the localisation of artillery firing events. It is concluded that the TALA provides a powerful situational awareness aid for passive surveillance operations.

  3. Observation of the initiation and progression of damage in compressively loaded composite plates containing a cutout

    NASA Technical Reports Server (NTRS)

    Waas, A.; Babcock, C., Jr.

    1986-01-01

    A series of experiments was carried out to determine the mechanism of failure in compressively loaded laminated plates with a circular cutout. Real time holographic interferometry and photomicrography are used to observe the progression of failure. These observations together with post experiment plate sectioning and deplying for interior damage observation provide useful information for modelling the failure process. It is revealed that the failure is initiated as a localised instability in the zero layers, at the hole surface. With increasing load extensive delamination cracking is observed. The progression of failure is by growth of these delaminations induced by delamination buckling. Upon reaching a critical state, catastrophic failure of the plate is observed. The levels of applied load and the rate at which these events occur depend on the plate stacking sequence.

  4. Allergic reaction to stainless steel sternotomy wires requiring removal: A case report and literature review.

    PubMed

    Lopez, J; Sachithanandan, A; Leow, M

    2016-06-01

    Hypersensitivity to stainless steel sternal sutures are an uncommon occurrence. We present a case of such a patient who developed chronic tissue overgranulation over a sternotomy wound eight weeks post-operatively. Primary suspicion was infection, a more common complication however radiological and laboratory investigation showed otherwise. Conservative management provided limited ephemeral success. After ensuring adequate sternal bone healing, the sutures and granulation tissue were eventually surgically removed without complication and the reoperated wound healed well.

  5. Numerical modelling of bifurcation and localisation in cohesive-frictional materials

    NASA Astrophysics Data System (ADS)

    de Borst, René

    1991-12-01

    Methods are reviewed for analysing highly localised failure and bifurcation modes in discretised mechanical systems as typically arise in numerical simulations of failure in soils, rocks, metals and concrete. By the example of a plane-strain biaxial test it is shown that strain softening and lack of normality in elasto-plastic constitutive equations and the ensuing loss of ellipticity of the governing field equations cause a pathological mesh dependence of numerical solutions for such problems, thus rendering the results effectively meaningless. The need for introduction of higher-order continuum models is emphasised to remedy this shortcoming of the conventional approach. For one such a continuum model, namely the unconstrained Cosserat continuum, it is demonstrated that meaningful and convergent solutions (in the sense that a finite width of the localisation zone is computed upon mesh refinement) can be obtained.

  6. Comparison of cyclic fatigue resistance of novel nickel-titanium rotary instruments.

    PubMed

    Capar, Ismail Davut; Ertas, Huseyin; Arslan, Hakan

    2015-04-01

    New files (ProTaper Next/HyFlex/OneShape) are made from novel nickel-titanium (NiTi) alloys/treatments. The purpose of this study was to compare the cyclic fatigue resistance of these new instruments with that of Revo-S instruments. Four groups of 20 NiTi endodontic instruments were tested in steel canals with a 3 mm radius and a 60° angle of curvature. The cyclic fatigue of the following NiTi instruments with a tip size 25 and 0.06 taper that were manufactured with different alloys was tested: ProTaper Next X2 (M-Wire), OneShape (conventional NiTi), Revo-S Shaping Universal (conventional NiTi) and HyFlex 25/0.6 (controlled memory NiTi wire). A one-way anova and post-hoc Tukey's test (α = 0.05) revealed that the HyFlex files had the highest fatigue resistance and the Revo-S had the least fatigue resistance among the groups (P < 0.001). © 2014 Australian Society of Endodontology.

  7. Isolated, extra-articular neck and shaft fractures of the 4th and 5th metacarpals: a comparison of transverse and bouquet (intra-medullary) pinning in 67 patients.

    PubMed

    Sletten, I N; Nordsletten, L; Husby, T; Ødegaard, R A; Hellund, J C; Kvernmo, H D

    2012-06-01

    Although extra-articular metacarpal fractures are common, there is no consensus on the mode of treatment. We evaluated the outcome in 67 patients operated for isolated, extra-articular fractures in the neck or shaft of the ulnar two metacarpals 28 months post-operatively. There were 22 bouquet (intra-medullary) pinnings and 45 transverse pinnings; 11 were lost to follow-up. Overall, hand function was good, and no difference was detected between the two methods (QuickDASH, grip strength, range of motion, VAS pain and VAS satisfaction). Many patients suffered complications: 12% had a superficial infection (all treated with transverse pinning with wires left exposed); 39% had some impairment in skin sensation; 29% reported cold intolerance; and 10% had other complications. Due to the potential risk of a secondary fracture of the neighbouring metacarpal after transverse pinning, we recommend bouquet (intra-medullary) pinning. We also recommend burying wires beneath the skin surface to avoid infection.

  8. Iron and cell death in Parkinson's disease: a nuclear microscopic study into iron-rich granules in the parkinsonian substantia nigra of primate models

    NASA Astrophysics Data System (ADS)

    Thong, P. S. P.; Watt, F.; Ponraj, D.; Leong, S. K.; He, Y.; Lee, T. K. Y.

    1999-10-01

    Parkinson's disease is a degenerative brain disease characterised by a loss of cells in the substantia nigra (SN) region of the brain and accompanying biochemical changes such as inhibition of mitochondrial function, increased iron concentrations and decreased glutathione levels in the parkinsonian SN. Though the aetiology of the disease is still unknown, the observed biochemical changes point to the involvement of oxidative stress. In particular, iron is suspected to play a role by promoting free radical production, leading to oxidative stress and cell death. The increase in iron in the parkinsonian SN has been confirmed by several research groups, both in human post-mortem brains and in brain tissue from parkinsonian animal models. However, the question remains as to whether the observed increase in iron is a cause or a consequence of the SN cell death process. Our previous study using unilaterally 1-methyl-4-phenyl-1,2,3,6-tetrahydro-pyridine (MPTP)-lesioned monkeys in a time sequence experiment has shown that the increase in bulk iron concentrations follow rather than precede dopaminergic cell death. However, changes in the localised iron concentrations, which may play a more direct role in SN cell death, may not be reflected at the bulk level. Indeed, we have observed iron-rich granules in parkinsonian SNs. From this time sequence study into the iron content of iron-rich granules in the SNs of an untreated control and unilaterally MPTP-lesioned parkinsonian models, we present the following observations: (1) Iron-rich granules are found in both control and parkinsonian SNs and are variable in size and iron content in any one model. (2) These iron-rich granules may be associated with neuromelanin granules found in the SN and are known to accumulate transition metal ions such as iron. (3) The early onset of bulk SN cell loss (35%) was accompanied by a significant elevation of iron in granules found in the MPTP-injected SN compared to the contra-lateral SN. This shows that localised iron increase may be an early event contributing to cell death. (4) The iron content in granules found in both the MPTP-injected and contra-lateral SNs is correlated with the degree of bulk SN cell loss (assessed by TH-immunohistochemistry) in individual models. This indicates a correlation between localised iron increase and cell loss, at least at the whole SN level. Our results are consistent with the observation that in Parkinson's disease (PD), neuronal cell death seems to be related to their neuromelanin content and support the proposal that iron-melanin interaction may play a role in oxidative neuronal cell death. Indeed, iron-saturated neuromelanin granules may act as centres of free radical production, contributing to localised cell death.

  9. 30 CFR 75.1003 - Insulation of trolley wires, trolley feeder wires and bare signal wires; guarding of trolley...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Insulation of trolley wires, trolley feeder wires and bare signal wires; guarding of trolley wires and trolley feeder wires. 75.1003 Section 75.1003... MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Trolley Wires and Trolley Feeder Wires § 75.1003...

  10. 30 CFR 75.1003 - Insulation of trolley wires, trolley feeder wires and bare signal wires; guarding of trolley...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Insulation of trolley wires, trolley feeder wires and bare signal wires; guarding of trolley wires and trolley feeder wires. 75.1003 Section 75.1003... MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Trolley Wires and Trolley Feeder Wires § 75.1003...

  11. Elastic Deformation Properties of Implanted Endobronchial Wire Stents in Benign and Malignant Bronchial Disease: A Radiographic In Vivo Evaluation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hautmann, Hubert; Rieger, Johannes; Huber, Rudolf M.

    1999-03-15

    Purpose: To evaluate the long-term mechanical behavior in vivo of expandable endobronchial wire stents, we imaged three different prostheses in the treatment of tracheobronchial disease. Methods: Six patients with bronchial stenoses (three benign, three malignant) underwent insertion of metallic stents. Two self-expandable Wallstents, two balloon-expandable tantalum Strecker stents and two self-expandable nitinol Accuflex stents were used. Measurements of deformation properties were performed during voluntary cough by means of fluoroscopy, at 1 month and 7-10 months after implantation. The procedures were videotaped, their images digitized and the narrowing of stent diameters calculated at intervals of 20 msec. Results: After stent implantationmore » all patients improved with respect to ventilatory function. Radial stent narrowing during cough reached 53% (Wallstent), 59% (tantalum Strecker stent), and 52% (nitinol Accuflex stent) of the relaxed post-implantation diameter. Stent compression was more marked in benign compared with malignant stenoses. In the long term permanent deformation occurred with the tantalum Strecker stents; the other stents were unchanged. Conclusion: Endobronchial wire stents can be helpful in the treatment of major airway collapse and obstructing bronchial lesions. However, evidence of material fatigue as a possible effect of exposure to recurrent mechanical stress on the flexible mesh tube may limit their long-term use. This seems to be predominantly important in benign bronchial collapse.« less

  12. Improvements in the Formation of Boron-Doped Diamond Coatings on Platinum Wires Using the Novel Nucleation Process (NNP)

    PubMed Central

    Fhaner, Mathew; Zhao, Hong; Bian, Xiaochun; Galligan, James J.; Swain, Greg M.

    2010-01-01

    In order to increase the initial nucleation density for the growth of boron-doped diamond on platinum wires, we employed the novel nucleation process (NNP) originally developed by Rotter et al. and discussed by others [1–3]. This pretreatment method involves (i) the initial formation of a thin carbon layer over the substrate followed by (ii) ultrasonic seeding of this “soft” carbon layer with nanoscale particles of diamond. This two-step pretreatment is followed by the deposition of boron-doped diamond by microwave plasma-assisted CVD. Both the diamond seed particles and sites on the carbon layer itself function as the initial nucleation zones for diamond growth from an H2-rich source gas mixture. We report herein on the characterization of the pre-growth carbon layer formed on Pt as well as boron-doped films grown for 2, 4 and 6 h post NNP pretreatment. Results from scanning electron microscopy, Raman spectroscopy and electrochemical studies are reported. The NNP method increases the initial nucleation density on Pt and leads to the formation of a continuous diamond film in a shorter deposition time than is typical for wires pretreated by conventional ultrasonic seeding. The results indicate that the pregrowth layer itself consists of nanoscopic domains of diamond and functions well to enhance the initial nucleation of diamond without any diamond powder seeding. PMID:21617759

  13. Photochemical internalisation of chemotherapy potentiates killing of multidrug-resistant breast and bladder cancer cells.

    PubMed

    Adigbli, D K; Wilson, D G G; Farooqui, N; Sousi, E; Risley, P; Taylor, I; Macrobert, A J; Loizidou, M

    2007-08-20

    Multidrug resistance (MDR) is the major confounding factor in adjuvant solid tumour chemotherapy. Increasing intracellular amounts of chemotherapeutics to circumvent MDR may be achieved by a novel delivery method, photochemical internalisation (PCI). PCI consists of the co-administration of drug and photosensitiser; upon light activation the latter induces intracellular release of organelle-bound drug. We investigated whether co-administration of hypericin (photosensitiser) with mitoxantrone (MTZ, chemotherapeutic) plus illumination potentiates cytotoxicity in MDR cancer cells. We mapped the extent of intracellular co-localisation of drug/photosensitiser. We determined whether PCI altered drug-excreting efflux pump P-glycoprotein (Pgp) expression or function in MDR cells. Bladder and breast cancer cells and their Pgp-overexpressing MDR subclones (MGHU1, MGHU1/R, MCF-7, MCF-7/R) were given hypericin/MTZ combinations, with/without blue-light illumination. Pilot experiments determined appropriate sublethal doses for each. Viability was determined by the 3-[4,5-dimethylthiazolyl]-2,5-diphenyltetrazolium bromide assay. Intracellular localisation was mapped by confocal microscopy. Pgp expression was detected by immunofluorescence and Pgp function investigated by Rhodamine123 efflux on confocal microscopy. MTZ alone (0.1-0.2 microg ml(-1)) killed up to 89% of drug-sensitive cells; MDR cells exhibited less cytotoxicity (6-28%). Hypericin (0.1-0.2 microM) effects were similar for all cells; light illumination caused none or minimal toxicity. In combination, MTZ /hypericin plus illumination, potentiated MDR cell killing, vs hypericin or MTZ alone. (MGHU1/R: 38.65 and 36.63% increase, P<0.05; MCF-7/R: 80.2 and 46.1% increase, P<0.001). Illumination of combined MTZ/hypericin increased killing by 28.15% (P<0.05 MGHU1/R) compared to dark controls. Intracytoplasmic vesicular co-localisation of MTZ/hypericin was evident before illumination and at serial times post-illumination. MTZ was always found in sensitive cell nuclei, but not in dark resistant cell nuclei. In illuminated resistant cells there was some mobilisation of MTZ into the nucleus. Pgp expression remained unchanged, regardless of drug exposure. Pgp efflux was blocked by the Pgp inhibitor verapamil (positive control) but not impeded by hypericin. The increased killing of MDR cancer cells demonstrated is consistent with PCI. PCI is a promising technique for enhancing treatment efficacy.

  14. Photochemical internalisation of chemotherapy potentiates killing of multidrug-resistant breast and bladder cancer cells

    PubMed Central

    Adigbli, D K; Wilson, D G G; Farooqui, N; Sousi, E; Risley, P; Taylor, I; MacRobert, A J; Loizidou, M

    2007-01-01

    Multidrug resistance (MDR) is the major confounding factor in adjuvant solid tumour chemotherapy. Increasing intracellular amounts of chemotherapeutics to circumvent MDR may be achieved by a novel delivery method, photochemical internalisation (PCI). PCI consists of the co-administration of drug and photosensitiser; upon light activation the latter induces intracellular release of organelle-bound drug. We investigated whether co-administration of hypericin (photosensitiser) with mitoxantrone (MTZ, chemotherapeutic) plus illumination potentiates cytotoxicity in MDR cancer cells. We mapped the extent of intracellular co-localisation of drug/photosensitiser. We determined whether PCI altered drug-excreting efflux pump P-glycoprotein (Pgp) expression or function in MDR cells. Bladder and breast cancer cells and their Pgp-overexpressing MDR subclones (MGHU1, MGHU1/R, MCF-7, MCF-7/R) were given hypericin/MTZ combinations, with/without blue-light illumination. Pilot experiments determined appropriate sublethal doses for each. Viability was determined by the 3-[4,5-dimethylthiazolyl]-2,5-diphenyltetrazolium bromide assay. Intracellular localisation was mapped by confocal microscopy. Pgp expression was detected by immunofluorescence and Pgp function investigated by Rhodamine123 efflux on confocal microscopy. MTZ alone (0.1–0.2 μg ml−1) killed up to 89% of drug-sensitive cells; MDR cells exhibited less cytotoxicity (6–28%). Hypericin (0.1–0.2 μM) effects were similar for all cells; light illumination caused none or minimal toxicity. In combination, MTZ /hypericin plus illumination, potentiated MDR cell killing, vs hypericin or MTZ alone. (MGHU1/R: 38.65 and 36.63% increase, P<0.05; MCF-7/R: 80.2 and 46.1% increase, P<0.001). Illumination of combined MTZ/hypericin increased killing by 28.15% (P<0.05 MGHU1/R) compared to dark controls. Intracytoplasmic vesicular co-localisation of MTZ/hypericin was evident before illumination and at serial times post-illumination. MTZ was always found in sensitive cell nuclei, but not in dark resistant cell nuclei. In illuminated resistant cells there was some mobilisation of MTZ into the nucleus. Pgp expression remained unchanged, regardless of drug exposure. Pgp efflux was blocked by the Pgp inhibitor verapamil (positive control) but not impeded by hypericin. The increased killing of MDR cancer cells demonstrated is consistent with PCI. PCI is a promising technique for enhancing treatment efficacy. PMID:17667930

  15. 4D strain localisation and fracture propagation in granite: the relative contribution of seismic and aseismic mechanisms to damage evolution during an in-situ triaxial deformation experiment at SOLEIL synchrotron

    NASA Astrophysics Data System (ADS)

    Cartwright-Taylor, A. L.; Fusseis, F.; Butler, I. B.; Flynn, M.; King, A.

    2017-12-01

    We present 4D x-ray data documenting strain localisation and fracture propagation in a microgranite, collected during a triaxial deformation experiment on the imaging beamline PSICHE at SOLEIL synchrotron. We loaded to failure a 2.97 mm diameter x 9.46 mm long cylindrical sample of Ailsa Craig microgranite, heat treated to 600 °C. The sample was deformed at 15 MPa confining pressure and 3x10-5 s-1 strain rate in a novel, x-ray transparent triaxial deformation apparatus, designed and built at the University of Edinburgh. 21 microtomographic volumes were acquired in intervals of 5-20 MPa (decreasing as failure approached), including one scan at peak differential stress of 200 MPa and three post-failure scans. A constant stress level was maintained during scanning and individual datasets were collected in 10 minutes using a white beam with an energy maximum at 66 keV in a spiral configuration. Reconstructions yielded image stacks of 1700x1700x4102 voxels with a voxel size of 2.7 μm. We analysed strain localisation and fracture propagation in the time series data. Local changes in volumetric and shear strains between time steps were quantified using 3D digital image correlation [1]. Fractures were segmented using a Multiscale Hessian fracture filter [2] and analysed for their orientations, dimensions and spatial distributions, and changes in these between time steps. In combination, these analyses show the extent and evolution of both local aseismic deformation and microcracking and their relative contributions to the overall damage evolution. Our data provides direct evidence of ongoing deformation processes, complementing the seminal results of Lockner et al. [3], who first imaged fault growth using acoustic emissions locations. Our results provide further insight into the aseismic mechanisms that dissipate >90% of the overall strain energy [4], and the interactions between these mechanisms and the developing microcracks. They also provide experimental verification of models for shear fracture formation whereby pre-existing flaws become connected by en-echelon tensile cracks that extend from their edges. [1] Hall, S. et al., 2010, Geotechnique 60, 315-322. [2] Voorn et al., 2015, J. Petroleum Sci. Eng. 127, 270-285. [3] Lockner, D., et al., 1991, Nature 350, 39-42. [4] Byerlee, J., 1993, Geology 21, 303-306.

  16. Dual wire welding torch and method

    DOEpatents

    Diez, Fernando Martinez; Stump, Kevin S.; Ludewig, Howard W.; Kilty, Alan L.; Robinson, Matthew M.; Egland, Keith M.

    2009-04-28

    A welding torch includes a nozzle with a first welding wire guide configured to orient a first welding wire in a first welding wire orientation, and a second welding wire guide configured to orient a second welding wire in a second welding wire orientation that is non-coplanar and divergent with respect to the first welding wire orientation. A method of welding includes moving a welding torch with respect to a workpiece joint to be welded. During moving the welding torch, a first welding wire is fed through a first welding wire guide defining a first welding wire orientation and a second welding wire is fed through a second welding wire guide defining a second welding wire orientation that is divergent and non-coplanar with respect to the first welding wire orientation.

  17. Auditory Models for Speech Analysis

    DTIC Science & Technology

    1988-01-01

    to encode stimulus frequency by firing in period with the clicks, up to a critical value. (Godfrey ct al., 1975). Some binaural processing appears to...masking experiments avoid sinosoiVs since a sinusoidal signal combined with a sinusoidal masker can cause " beats " due to regular fluctuations in the...such as sound localisation (Lyon, 1983). Jeffress (1956) proposed a binaural localisation model where the "mechanism receives impulses from corresponding

  18. Towards Unmanned Systems for Dismounted Operations in the Canadian Forces

    DTIC Science & Technology

    2011-01-01

    LIDAR , and RADAR) and lower power/mass, passive imaging techniques such as structure from motion and simultaneous localisation and mapping ( SLAM ...sensors and learning algorithms. 5.1.2 Simultaneous localisation and mapping SLAM algorithms concurrently estimate a robot pose and a map of unique...locations and vehicle pose are part of the SLAM state vector and are estimated in each update step. AISS developed a monocular camera-based SLAM

  19. Isolation, sequencing and expression of RED, a novel human gene encoding an acidic-basic dipeptide repeat.

    PubMed

    Assier, E; Bouzinba-Segard, H; Stolzenberg, M C; Stephens, R; Bardos, J; Freemont, P; Charron, D; Trowsdale, J; Rich, T

    1999-04-16

    A novel human gene RED, and the murine homologue, MuRED, were cloned. These genes were named after the extensive stretch of alternating arginine (R) and glutamic acid (E) or aspartic acid (D) residues that they contain. We term this the 'RED' repeat. The genes of both species were expressed in a wide range of tissues and we have mapped the human gene to chromosome 5q22-24. MuRED and RED shared 98% sequence identity at the amino acid level. The open reading frame of both genes encodes a 557 amino acid protein. RED fused to a fluorescent tag was expressed in nuclei of transfected cells and localised to nuclear dots. Co-localisation studies showed that these nuclear dots did not contain either PML or Coilin, which are commonly found in the POD or coiled body nuclear compartments. Deletion of the amino terminal 265 amino acids resulted in a failure to sort efficiently to the nucleus, though nuclear dots were formed. Deletion of a further 50 amino acids from the amino terminus generates a protein that can sort to the nucleus but is unable to generate nuclear dots. Neither construct localised to the nucleolus. The characteristics of RED and its nuclear localisation implicate it as a regulatory protein, possibly involved in transcription.

  20. The plasma membrane recycling pathway and cell polarity in plants: studies on PIN proteins.

    PubMed

    Boutté, Yohann; Crosnier, Marie-Thérèse; Carraro, Nicola; Traas, Jan; Satiat-Jeunemaitre, Béatrice

    2006-04-01

    The PIN-FORMED (PIN) proteins are plasma-membrane-associated facilitators of auxin transport. They are often targeted to one side of the cell only through subcellular mechanisms that remain largely unknown. Here, we have studied the potential roles of the cytoskeleton and endomembrane system in the localisation of PIN proteins. Immunocytochemistry and image analysis on root cells from Arabidopsis thaliana and maize showed that 10-30% of the intracellular PIN proteins mapped to the Golgi network, but never to prevacuolar compartments. The remaining 70-90% were associated with yet to be identified structures. The maintenance of PIN proteins at the plasma membrane depends on a BFA-sensitive machinery, but not on microtubules and actin filaments. The polar localisation of PIN proteins at the plasmamembrane was not reflected by any asymmetric distribution of cytoplasmic organelles. In addition, PIN proteins were inserted in a symmetrical manner at both sides of the cell plate during cytokinesis. Together, the data indicate that the localisation of PIN proteins is a postmitotic event, which depends on local characteristics of the plasma membrane and its direct environment. In this context, we present evidence that microtubule arrays might define essential positional information for PIN localisation. This information seems to require the presence of an intact cell wall.

  1. Quantitative Evaluation of Stereo Visual Odometry for Autonomous Vessel Localisation in Inland Waterway Sensing Applications

    PubMed Central

    Kriechbaumer, Thomas; Blackburn, Kim; Breckon, Toby P.; Hamilton, Oliver; Rivas Casado, Monica

    2015-01-01

    Autonomous survey vessels can increase the efficiency and availability of wide-area river environment surveying as a tool for environment protection and conservation. A key challenge is the accurate localisation of the vessel, where bank-side vegetation or urban settlement preclude the conventional use of line-of-sight global navigation satellite systems (GNSS). In this paper, we evaluate unaided visual odometry, via an on-board stereo camera rig attached to the survey vessel, as a novel, low-cost localisation strategy. Feature-based and appearance-based visual odometry algorithms are implemented on a six degrees of freedom platform operating under guided motion, but stochastic variation in yaw, pitch and roll. Evaluation is based on a 663 m-long trajectory (>15,000 image frames) and statistical error analysis against ground truth position from a target tracking tachymeter integrating electronic distance and angular measurements. The position error of the feature-based technique (mean of ±0.067 m) is three times smaller than that of the appearance-based algorithm. From multi-variable statistical regression, we are able to attribute this error to the depth of tracked features from the camera in the scene and variations in platform yaw. Our findings inform effective strategies to enhance stereo visual localisation for the specific application of river monitoring. PMID:26694411

  2. Does the use of an iodine-containing contrast agent to visualise the PICC tip in preterm babies cause hypothyroidism? A randomised controlled trial.

    PubMed

    Rath, Chandra Prakash; Thomas, Mary; Sullivan, Drew; Kluckow, Martin

    2018-05-28

    To compare thyroid function tests in preterm neonates (<30 weeks and >48 hour old) exposed to iodine-based contrast with controls and ascertain the certainty of peripherally inserted central catheter (PICC) tip position. Infants requiring a PICC were randomised to receive 0.3 mL of iodine-containing contrast or normal saline. The primary outcome was the difference in thyroid-stimulating hormone (TSH) levels on day 14 post PICC insertion and on day 28 of life. 41 infants were randomised with no significant differences in TSH level (mIU/L) at day 14 post PICC insertion (3.1 vs 2) or on day 28 of life (2.2 vs 1.7). The PICC tip was more easily localised in the contrast group (85% vs 55%). Urinary iodine levels were significantly increased in the contrast-exposed group. Use of contrast did not suppress subsequent thyroid function and helped visualise the PICC tip with more certainty. ACTRN 12614000560695, pre-result. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  3. Single-Layer, All-Metal Patch Antenna Element with Wide Bandwidth

    NASA Technical Reports Server (NTRS)

    Chamberlain, Neil F.; Hodges, Richard E.; Zawardzki, Mark S.

    2012-01-01

    It is known that the impedance at the center of a patch antenna element is a short circuit, implying that a wire or post can be connected from the patch to the groundplane at this point without impacting radiation performance. In principle, this central post can be used to support the patch element, thus eliminating the need for dielectric. In spaceborne applications, this approach is problematic because a patch element supported by a single, thin post is highly susceptible to acoustic loads during launch. The technology reported here uses a large-diameter center post as its supporting structure. The supporting structure allows for the fabrication of a sufficiently rigid antenna element that can survive launch loads. The post may be either hollow or solid, depending on fabrication approach and/or mass constraints. The patch antenna element and support post are envisioned as being fabricated (milled) from a single piece of aluminum or other metal. Alternately, the patch plate and support column can be fabricated separately and then joined using fasteners, adhesive, or welding. Casting and electroforming are also viable techniques for manufacturing the metal patch part(s). The patch structure is then either bonded or fastened to the supporting groundplane. Arrays of patch elements can be fabricated by attaching several structures to a common groundplane/support structure.

  4. The Nuclear Protein Database (NPD): sub-nuclear localisation and functional annotation of the nuclear proteome

    PubMed Central

    Dellaire, G.; Farrall, R.; Bickmore, W.A.

    2003-01-01

    The Nuclear Protein Database (NPD) is a curated database that contains information on more than 1300 vertebrate proteins that are thought, or are known, to localise to the cell nucleus. Each entry is annotated with information on predicted protein size and isoelectric point, as well as any repeats, motifs or domains within the protein sequence. In addition, information on the sub-nuclear localisation of each protein is provided and the biological and molecular functions are described using Gene Ontology (GO) terms. The database is searchable by keyword, protein name, sub-nuclear compartment and protein domain/motif. Links to other databases are provided (e.g. Entrez, SWISS-PROT, OMIM, PubMed, PubMed Central). Thus, NPD provides a gateway through which the nuclear proteome may be explored. The database can be accessed at http://npd.hgu.mrc.ac.uk and is updated monthly. PMID:12520015

  5. A Variational Reduction and the Existence of a Fully Localised Solitary Wave for the Three-Dimensional Water-Wave Problem with Weak Surface Tension

    NASA Astrophysics Data System (ADS)

    Buffoni, Boris; Groves, Mark D.; Wahlén, Erik

    2017-12-01

    Fully localised solitary waves are travelling-wave solutions of the three- dimensional gravity-capillary water wave problem which decay to zero in every horizontal spatial direction. Their existence has been predicted on the basis of numerical simulations and model equations (in which context they are usually referred to as `lumps'), and a mathematically rigorous existence theory for strong surface tension (Bond number {β} greater than {1/3} ) has recently been given. In this article we present an existence theory for the physically more realistic case {0 < β < 1/3} . A classical variational principle for fully localised solitary waves is reduced to a locally equivalent variational principle featuring a perturbation of the functional associated with the Davey-Stewartson equation. A nontrivial critical point of the reduced functional is found by minimising it over its natural constraint set.

  6. A Variational Reduction and the Existence of a Fully Localised Solitary Wave for the Three-Dimensional Water-Wave Problem with Weak Surface Tension

    NASA Astrophysics Data System (ADS)

    Buffoni, Boris; Groves, Mark D.; Wahlén, Erik

    2018-06-01

    Fully localised solitary waves are travelling-wave solutions of the three- dimensional gravity-capillary water wave problem which decay to zero in every horizontal spatial direction. Their existence has been predicted on the basis of numerical simulations and model equations (in which context they are usually referred to as `lumps'), and a mathematically rigorous existence theory for strong surface tension (Bond number {β} greater than {1/3}) has recently been given. In this article we present an existence theory for the physically more realistic case {0 < β < 1/3}. A classical variational principle for fully localised solitary waves is reduced to a locally equivalent variational principle featuring a perturbation of the functional associated with the Davey-Stewartson equation. A nontrivial critical point of the reduced functional is found by minimising it over its natural constraint set.

  7. From dichoptic to dichotic: historical contrasts between binocular vision and binaural hearing.

    PubMed

    Wade, Nicholas J; Ono, Hiroshi

    2005-01-01

    Phenomena involving vision with two eyes have been commented upon for several thousand years whereas those concerned with hearing with two ears have a much more recent history. Studies of binocular vision and binaural hearing are contrasted with respect to the singleness of the percept, experimental manipulations of dichoptic and dichotic stimuli, eye and ear dominance, spatial localisation, and the instruments used to stimulate the paired organs. One of the principal phenomena that led to studies of dichotic hearing was dichoptic colour mixing. There was similar disagreement regarding whether colours or sounds could be combined when presented to different paired organs. Direction and distance in visual localisation were analysed before those for auditory localisation, partly due to difficulties in controlling the stimuli. Instruments for investigating binocular vision, like the stereoscope and pseudoscope, were invented before those for binaural hearing, like the stethophone and pseudophone.

  8. Recovery of infrastructure networks after localised attacks.

    PubMed

    Hu, Fuyu; Yeung, Chi Ho; Yang, Saini; Wang, Weiping; Zeng, An

    2016-04-14

    The stability of infrastructure network is always a critical issue studied by researchers in different fields. A lot of works have been devoted to reveal the robustness of the infrastructure networks against random and malicious attacks. However, real attack scenarios such as earthquakes and typhoons are instead localised attacks which are investigated only recently. Unlike previous studies, we examine in this paper the resilience of infrastructure networks by focusing on the recovery process from localised attacks. We introduce various preferential repair strategies and found that they facilitate and improve network recovery compared to that of random repairs, especially when population size is uneven at different locations. Moreover, our strategic repair methods show similar effectiveness as the greedy repair. The validations are conducted on simulated networks, and on real networks with real disasters. Our method is meaningful in practice as it can largely enhance network resilience and contribute to network risk reduction.

  9. The Rényi divergence enables accurate and precise cluster analysis for localisation microscopy.

    PubMed

    Staszowska, Adela D; Fox-Roberts, Patrick; Hirvonen, Liisa M; Peddie, Christopher J; Collinson, Lucy M; Jones, Gareth E; Cox, Susan

    2018-06-01

    Clustering analysis is a key technique for quantitatively characterising structures in localisation microscopy images. To build up accurate information about biological structures, it is critical that the quantification is both accurate (close to the ground truth) and precise (has small scatter and is reproducible). Here we describe how the Rényi divergence can be used for cluster radius measurements in localisation microscopy data. We demonstrate that the Rényi divergence can operate with high levels of background and provides results which are more accurate than Ripley's functions, Voronoi tesselation or DBSCAN. Data supporting this research will be made accessible via a web link. Software codes developed for this work can be accessed via http://coxphysics.com/Renyi_divergence_software.zip. Implemented in C ++. Correspondence and requests for materials can be also addressed to the corresponding author. adela.staszowska@gmail.com or susan.cox@kcl.ac.uk. Supplementary data are available at Bioinformatics online.

  10. Capsule-odometer: a concept to improve accurate lesion localisation.

    PubMed

    Karargyris, Alexandros; Koulaouzidis, Anastasios

    2013-09-21

    In order to improve lesion localisation in small-bowel capsule endoscopy, a modified capsule design has been proposed incorporating localisation and - in theory - stabilization capabilities. The proposed design consists of a capsule fitted with protruding wheels attached to a spring-mechanism. This would act as a miniature odometer, leading to more accurate lesion localization information in relation to the onset of the investigation (spring expansion e.g., pyloric opening). Furthermore, this capsule could allow stabilization of the recorded video as any erratic, non-forward movement through the gut is minimised. Three-dimensional (3-D) printing technology was used to build a capsule prototype. Thereafter, miniature wheels were also 3-D printed and mounted on a spring which was attached to conventional capsule endoscopes for the purpose of this proof-of-concept experiment. In vitro and ex vivo experiments with porcine small-bowel are presented herein. Further experiments have been scheduled.

  11. Clutter elimination for deep clinical optoacoustic imaging using localised vibration tagging (LOVIT)☆

    PubMed Central

    Jaeger, Michael; Bamber, Jeffrey C.; Frenz, Martin

    2013-01-01

    This paper investigates a novel method which allows clutter elimination in deep optoacoustic imaging. Clutter significantly limits imaging depth in clinical optoacoustic imaging, when irradiation optics and ultrasound detector are integrated in a handheld probe for flexible imaging of the human body. Strong optoacoustic transients generated at the irradiation site obscure weak signals from deep inside the tissue, either directly by propagating towards the probe, or via acoustic scattering. In this study we demonstrate that signals of interest can be distinguished from clutter by tagging them at the place of origin with localised tissue vibration induced by the acoustic radiation force in a focused ultrasonic beam. We show phantom results where this technique allowed almost full clutter elimination and thus strongly improved contrast for deep imaging. Localised vibration tagging by means of acoustic radiation force is especially promising for integration into ultrasound systems that already have implemented radiation force elastography. PMID:25302147

  12. Genomic and Histopathological Tissue Biomarkers That Predict Radiotherapy Response in Localised Prostate Cancer

    PubMed Central

    Wilkins, Anna; Dearnaley, David; Somaiah, Navita

    2015-01-01

    Localised prostate cancer, in particular, intermediate risk disease, has varied survival outcomes that cannot be predicted accurately using current clinical risk factors. External beam radiotherapy (EBRT) is one of the standard curative treatment options for localised disease and its efficacy is related to wide ranging aspects of tumour biology. Histopathological techniques including immunohistochemistry and a variety of genomic assays have been used to identify biomarkers of tumour proliferation, cell cycle checkpoints, hypoxia, DNA repair, apoptosis, and androgen synthesis, which predict response to radiotherapy. Global measures of genomic instability also show exciting capacity to predict survival outcomes following EBRT. There is also an urgent clinical need for biomarkers to predict the radiotherapy fraction sensitivity of different prostate tumours and preclinical studies point to possible candidates. Finally, the increased resolution of next generation sequencing (NGS) is likely to enable yet more precise molecular predictions of radiotherapy response and fraction sensitivity. PMID:26504789

  13. Model updating strategy for structures with localised nonlinearities using frequency response measurements

    NASA Astrophysics Data System (ADS)

    Wang, Xing; Hill, Thomas L.; Neild, Simon A.; Shaw, Alexander D.; Haddad Khodaparast, Hamed; Friswell, Michael I.

    2018-02-01

    This paper proposes a model updating strategy for localised nonlinear structures. It utilises an initial finite-element (FE) model of the structure and primary harmonic response data taken from low and high amplitude excitations. The underlying linear part of the FE model is first updated using low-amplitude test data with established techniques. Then, using this linear FE model, the nonlinear elements are localised, characterised, and quantified with primary harmonic response data measured under stepped-sine or swept-sine excitations. Finally, the resulting model is validated by comparing the analytical predictions with both the measured responses used in the updating and with additional test data. The proposed strategy is applied to a clamped beam with a nonlinear mechanism and good agreements between the analytical predictions and measured responses are achieved. Discussions on issues of damping estimation and dealing with data from amplitude-varying force input in the updating process are also provided.

  14. Une localisation exceptionnelle de la tuberculose vertébrale Mal de Pott sous-occipital

    PubMed Central

    Yahyaoui, Sana; Majdoub, Senda; Zaghouani, Houneida; Fradj, Hosni Ben; Bakir, Dejla; Bouajina, Elyes; Kraiem, Chakib

    2013-01-01

    Le mal de Pott est la forme la plus commune de la tuberculose osseuse touchant essentiellement le rachis dorso-lombaire. La localisation sous-occipitale reste exceptionnelle. Le diagnostic de cette entité est le plus souvent tardif ce qui expose à des complications graves. Les radiographies standard ne sont parlantes qu’à un stade tardif de la maladie, d'où l'intérêt de l'imagerie moderne notamment la tomodensitométrie (TDM) et l'imagerie par résonance magnétique (IRM) qui permettent un diagnostic précoce. Nous rapportons un nouveau cas de tuberculose sous-occipitale. Le diagnostic était posé sur l'imagerie en coupe et confirmé histologiquement à la biopsie transorale. Sont rappelés les aspects en imagerie de cette localisation particulière du mal de Pott. PMID:23819005

  15. Recovery of infrastructure networks after localised attacks

    PubMed Central

    Hu, Fuyu; Yeung, Chi Ho; Yang, Saini; Wang, Weiping; Zeng, An

    2016-01-01

    The stability of infrastructure network is always a critical issue studied by researchers in different fields. A lot of works have been devoted to reveal the robustness of the infrastructure networks against random and malicious attacks. However, real attack scenarios such as earthquakes and typhoons are instead localised attacks which are investigated only recently. Unlike previous studies, we examine in this paper the resilience of infrastructure networks by focusing on the recovery process from localised attacks. We introduce various preferential repair strategies and found that they facilitate and improve network recovery compared to that of random repairs, especially when population size is uneven at different locations. Moreover, our strategic repair methods show similar effectiveness as the greedy repair. The validations are conducted on simulated networks, and on real networks with real disasters. Our method is meaningful in practice as it can largely enhance network resilience and contribute to network risk reduction. PMID:27075559

  16. Effect of monomer composition of polymer matrix on flexural properties of glass fibre-reinforced orthodontic archwire.

    PubMed

    Ohtonen, J; Vallittu, P K; Lassila, L V J

    2013-02-01

    To compare force levels obtained from glass fibre-reinforced composite (FRC) archwires. Specifically, FRC wires were compared with polymer matrices having different dimethacrylate monomer compositions. FRC material (E-glass provided by Stick Tech Ltd, Turku, Finland) with continuous unidirectional glass fibres and four different types of dimethacrylate monomer compositions for the resin matrix were tested. Cross-sectionally round FRC archwires fitting into the 0.3 mm slot of a bracket were divided into 16 groups with six specimens in each group. Glass fibres were impregnated by the manufacturer, and they were initially light-cured by hand light-curing unit or additionally post-cured in light-curing oven. The FRC archwire specimens were tested at 37°C according to a three-point bending test in dry and wet conditions using a span length of 10 mm and a crosshead speed of 1.0 mm/minute. The wires were loaded until final failure. The data were statistically analysed using analysis of variance (ANOVA). The dry FRC archwire specimens revealed higher load values than water stored ones, regardless of the polymer matrix. A majority of the FRC archwires showed higher load values after being post-cured. ANOVA revealed that the polymer matrix, curing method, and water storage had a significant effect (P < 0.05) on the flexural behaviour of the FRC archwire. Polymer matrix composition, curing method, and water storage affected the flexural properties and thus, force level and working range which could be obtained from the FRC archwire.

  17. Reliability Criteria for Thick Bonding Wire.

    PubMed

    Dagdelen, Turker; Abdel-Rahman, Eihab; Yavuz, Mustafa

    2018-04-17

    Bonding wire is one of the main interconnection techniques. Thick bonding wire is widely used in power modules and other high power applications. This study examined the case for extending the use of traditional thin wire reliability criteria, namely wire flexure and aspect ratio, to thick wires. Eleven aluminum (Al) and aluminum coated copper (CucorAl) wire samples with diameter 300 μm were tested experimentally. The wire response was measured using a novel non-contact method. High fidelity FEM models of the wire were developed and validated. We found that wire flexure is not correlated to its stress state or fatigue life. On the other hand, aspect ratio is a consistent criterion of thick wire fatigue life. Increasing the wire aspect ratio lowers its critical stress and increases its fatigue life. Moreover, we found that CucorAl wire has superior performance and longer fatigue life than Al wire.

  18. Reliability Criteria for Thick Bonding Wire

    PubMed Central

    Yavuz, Mustafa

    2018-01-01

    Bonding wire is one of the main interconnection techniques. Thick bonding wire is widely used in power modules and other high power applications. This study examined the case for extending the use of traditional thin wire reliability criteria, namely wire flexure and aspect ratio, to thick wires. Eleven aluminum (Al) and aluminum coated copper (CucorAl) wire samples with diameter 300 μm were tested experimentally. The wire response was measured using a novel non-contact method. High fidelity FEM models of the wire were developed and validated. We found that wire flexure is not correlated to its stress state or fatigue life. On the other hand, aspect ratio is a consistent criterion of thick wire fatigue life. Increasing the wire aspect ratio lowers its critical stress and increases its fatigue life. Moreover, we found that CucorAl wire has superior performance and longer fatigue life than Al wire. PMID:29673194

  19. 30 CFR 75.1003-1 - Other requirements for guarding of trolley wires and trolley feeder wires.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... wires and trolley feeder wires. 75.1003-1 Section 75.1003-1 Mineral Resources MINE SAFETY AND HEALTH... Trolley Wires and Trolley Feeder Wires § 75.1003-1 Other requirements for guarding of trolley wires and trolley feeder wires. Adequate precaution shall be taken to insure that equipment being moved along...

  20. 30 CFR 75.1003-1 - Other requirements for guarding of trolley wires and trolley feeder wires.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... wires and trolley feeder wires. 75.1003-1 Section 75.1003-1 Mineral Resources MINE SAFETY AND HEALTH... Trolley Wires and Trolley Feeder Wires § 75.1003-1 Other requirements for guarding of trolley wires and trolley feeder wires. Adequate precaution shall be taken to insure that equipment being moved along...

  1. Controls on the rheological properties of peridotite at a palaeosubduction interface: A transect across the base of the Oman-UAE ophiolite

    NASA Astrophysics Data System (ADS)

    Ambrose, Tyler K.; Wallis, David; Hansen, Lars N.; Waters, Dave J.; Searle, Michael P.

    2018-06-01

    Studies of experimentally deformed rocks and small-scale natural shear zones have demonstrated that volumetrically minor phases can control strain localisation by limiting grain growth and promoting grain-size sensitive deformation mechanisms. These small-scale studies are often used to infer a critical role for minor phases in the development of plate boundaries. However, the role of minor phases in strain localisation at an actual plate boundary remains to be tested by direct observation. In order to test the hypothesis that minor phases control strain localisation at plate boundaries, we conducted microstructural analyses of peridotite samples collected along a ∼1 km transect across the base of the Oman-United Arab Emirates (UAE) ophiolite. The base of the ophiolite is marked by the Semail thrust, which represents the now exhumed contact between subducted oceanic crust and the overlying mantle wedge. As such, the base of the ophiolite provides the opportunity to directly examine a former plate boundary. Our results demonstrate that the mean olivine grain size is inversely proportional to the abundance of minor phases (primarily orthopyroxene, as well as clinopyroxene, hornblende, and spinel), consistent with suppression of grain growth by grain-boundary pinning. Our results also reveal that mean olivine grain size is proportional to CPO strength (both of which generally decrease towards the metamorphic sole), suggesting that the fraction of strain produced by different deformation mechanisms varied spatially. Experimentally-derived flow laws indicate that under the inferred deformation conditions, the viscosity of olivine was grain-size sensitive. As such, grain size, and thereby the abundance of minor phases, influenced viscosity during subduction-related deformation along the base of the mantle wedge. We calculate an order of magnitude decrease in the viscosity of olivine towards the base of the ophiolite, which suggests strain was localised near the subduction interface. Our data indicate that this rheological weakening was primarily the result of more abundant minor phases near the base of the ophiolite. Our interpretations are consistent with those of previous studies on experimentally deformed rocks and smaller-scale natural shear zones that indicate minor phases can exert the primary control on strain localisation. However, our study demonstrates for the first time that minor phases can control strain localisation at the scales relevant to a major plate boundary.

  2. Regional chromosomal localisation of APOA2 to 1q21-1q23.

    PubMed

    Middleton-Price, H R; van den Berghe, J A; Scott, J; Knott, T J; Malcolm, S

    1988-07-01

    Using in situ hybridisation, we have mapped APOA2 to the 1q21-1q23 region of chromosome 1. DNA hybridisation to somatic cell hybrids made from cells carrying a balanced translocation between X and 1 confirms the localisation as proximal to 1q23. This was further confirmed by the presence of two polymorphic alleles in a cell line carrying a deletion of 1q25-1q32.

  3. Interobserver variability of radiation therapists aligning to fiducial markers for prostate radiation therapy.

    PubMed

    Deegan, Timothy; Owen, Rebecca; Holt, Tanya; Roberts, Lisa; Biggs, Jennifer; McCarthy, Alicia; Parfitt, Matthew; Fielding, Andrew

    2013-08-01

    As the use of fiducial markers (FMs) for the localisation of the prostate during external beam radiation therapy (EBRT) has become part of routine practice, radiation therapists (RTs) have become increasingly responsible for online image interpretation. The aim of this investigation was to quantify the limits of agreement (LoA) between RTs when localising to FMs with orthogonal kilovoltage (kV) imaging. Six patients receiving prostate EBRT utilising FMs were included in this study. Treatment localisation was performed using kV imaging prior to each fraction. Online stereoscopic assessment of FMs, performed by the treating RTs, was compared with the offline assessment by three RTs. Observer agreement was determined by pairwise Bland-Altman analysis. Stereoscopic analysis of 225 image pairs was performed online at the time of treatment, and offline by three RT observers. Eighteen pairwise Bland-Altman analyses were completed to assess the level of agreement between observers. Localisation by RTs was found to be within clinically acceptable 95% LoAs. Small differences between RTs, in both the online and offline setting, were found to be within clinically acceptable limits. RTs were able to make consistent and reliable judgements when matching FMs on planar kV imaging. © 2013 The Authors. Journal of Medical Imaging and Radiation Oncology © 2013 The Royal Australian and New Zealand College of Radiologists.

  4. Mps1 kinase-dependent Sgo2 centromere localisation mediates cohesin protection in mouse oocyte meiosis I.

    PubMed

    El Yakoubi, Warif; Buffin, Eulalie; Cladière, Damien; Gryaznova, Yulia; Berenguer, Inés; Touati, Sandra A; Gómez, Rocío; Suja, José A; van Deursen, Jan M; Wassmann, Katja

    2017-09-25

    A key feature of meiosis is the step-wise removal of cohesin, the protein complex holding sister chromatids together, first from arms in meiosis I and then from the centromere region in meiosis II. Centromeric cohesin is protected by Sgo2 from Separase-mediated cleavage, in order to maintain sister chromatids together until their separation in meiosis II. Failures in step-wise cohesin removal result in aneuploid gametes, preventing the generation of healthy embryos. Here, we report that kinase activities of Bub1 and Mps1 are required for Sgo2 localisation to the centromere region. Mps1 inhibitor-treated oocytes are defective in centromeric cohesin protection, whereas oocytes devoid of Bub1 kinase activity, which cannot phosphorylate H2A at T121, are not perturbed in cohesin protection as long as Mps1 is functional. Mps1 and Bub1 kinase activities localise Sgo2 in meiosis I preferentially to the centromere and pericentromere respectively, indicating that Sgo2 at the centromere is required for protection.In meiosis I centromeric cohesin is protected by Sgo2 from Separase-mediated cleavage ensuring that sister chromatids are kept together until their separation in meiosis II. Here the authors demonstrate that Bub1 and Mps1 kinase activities are required for Sgo2 localisation to the centromere region.

  5. Extinction of auditory stimuli in hemineglect: Space versus ear.

    PubMed

    Spierer, Lucas; Meuli, Reto; Clarke, Stephanie

    2007-02-01

    Unilateral extinction of auditory stimuli, a key feature of the neglect syndrome, was investigated in 15 patients with right (11), left (3) or bilateral (1) hemispheric lesions using a verbal dichotic condition, in which each ear received simultaneously one word, and a interaural-time-difference (ITD) diotic condition, in which both ears received both words lateralised by means of ITD. Additional investigations included sound localisation, visuo-spatial attention and general cognitive status. Five patients presented a significant asymmetry in the ITD diotic test, due to a decrease of left hemispace reporting but no asymmetry was found in dichotic listening. Six other patients presented a significant asymmetry in the dichotic test due to a significant decrease of left or right ear reporting, but no asymmetry in diotic listening. Ten of the above patients presented mild to severe deficits in sound localisation and eight signs of visuo-spatial neglect (three with selective asymmetry in the diotic and five in the dichotic task). Four other patients presented a significant asymmetry in both the diotic and dichotic listening tasks. Three of them presented moderate deficits in localisation and all four moderate visuo-spatial neglect. Thus, extinction for left ear and left hemispace can double dissociate, suggesting distinct underlying neural processes. Furthermore, the co-occurrence with sound localisation disturbance and with visuo-spatial hemineglect speaks in favour of the involvement of multisensory attentional representations.

  6. Utility of stereoelectroencephalography in preoperative assessment of temporal lobe epilepsy.

    PubMed Central

    Binnie, C D; Elwes, R D; Polkey, C E; Volans, A

    1994-01-01

    Of 269 consecutive patients entered into a preoperative assessment programme for possible surgical treatment of epilepsy, 33 had intracranial recording (SEEG) with combined subdural and depth electrodes for the purpose of localising a suspected temporal site of seizure onset. The findings in these patients are analysed with particular reference to: 1) the criteria of selection for SEEG and their validity; 2) information on SEEG compared with that obtained by less invasive means, including foramen ovale telemetry; 3) information on the use of intracerebral electrodes compared with subdural placements; 4) possible predictors of failure of localisation by SEEG and of surgical outcome. It was concluded that SEEG had usefully contributed to the management of 69% of the patients in whom it was used, establishing a previously unidentified site of seizure onset in 33%, correcting an erroneous localisation in 15%, and establishing inoperability in 21% of patients. No predictors of failure of SEEG or of surgery emerged; thus there was no evidence of unnecessary use of this procedure. Five patients were found with incorrect lateralisation of seizure onset on foramen ovale recording (of a total of 192 foramen ovale telemetries). Localisation of the ictal onset zone either by the distribution of inter-ictal discharges or by the initial ictal changes at subdural electrodes was unreliable, confirming the need for ictal, depth recordings. PMID:8301306

  7. Development of Indicators to Assess Quality of Care for Prostate Cancer.

    PubMed

    Nag, Nupur; Millar, Jeremy; Davis, Ian D; Costello, Shaun; Duthie, James B; Mark, Stephen; Delprado, Warick; Smith, David; Pryor, David; Galvin, David; Sullivan, Frank; Murphy, Áine C; Roder, David; Elsaleh, Hany; Currow, David; White, Craig; Skala, Marketa; Moretti, Kim L; Walker, Tony; De Ieso, Paolo; Brooks, Andrew; Heathcote, Peter; Frydenberg, Mark; Thavaseelan, Jeffery; Evans, Sue M

    2016-02-20

    The development, monitoring, and reporting of indicator measures that describe standard of care provide the gold standard for assessing quality of care and patient outcomes. Although indicator measures have been reported, little evidence of their use in measuring and benchmarking performance is available. A standard set, defining numerator, denominator, and risk adjustments, will enable global benchmarking of quality of care. To develop a set of indicators to enable assessment and reporting of quality of care for men with localised prostate cancer (PCa). Candidate indicators were identified from the literature. An international panel was invited to participate in a modified Delphi process. Teleconferences were held before and after each voting round to provide instruction and to review results. Panellists were asked to rate each proposed indicator on a Likert scale of 1-9 in a two-round iterative process. Calculations required to report on the endorsed indicators were evaluated and modified to reflect the data capture of the Prostate Cancer Outcomes Registry-Australia and New Zealand (PCOR-ANZ). A total of 97 candidate indicators were identified, of which 12 were endorsed. The set includes indicators covering pre-, intra-, and post-treatment of PCa care, within the limits of the data captured by PCOR-ANZ. The 12 endorsed quality measures enable international benchmarking on the quality of care of men with localised PCa. Reporting on these indicators enhances safety and efficacy of treatment, reduces variation in care, and can improve patient outcomes. PCa has the highest incidence of all cancers in men. Early diagnosis and relatively high survival rates mean issues of quality of care and best possible health outcomes for patients are important. This paper identifies 12 important measurable quality indicators in PCa care. Copyright © 2016 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  8. T-cell brain infiltration and immature antigen-presenting cells in transgenic models of Alzheimer's disease-like cerebral amyloidosis.

    PubMed

    Ferretti, M T; Merlini, M; Späni, C; Gericke, C; Schweizer, N; Enzmann, G; Engelhardt, B; Kulic, L; Suter, T; Nitsch, R M

    2016-05-01

    Cerebral beta-amyloidosis, one of the pathological hallmarks of Alzheimer's disease (AD), elicits a well-characterised, microglia-mediated local innate immune response. In contrast, it is not clear whether cells of the adaptive immune system, in particular T-cells, react to cerebral amyloidosis in AD. Even though parenchymal T-cells have been described in post-mortem brains of AD patients, it is not known whether infiltrating T-cells are specifically recruited to the extracellular deposits of beta-amyloid, and whether they are locally activated into proliferating, effector cells upon interaction with antigen-presenting cells (APCs). To address these issues we have analysed by confocal microscopy and flow-cytometry the localisation and activation status of both T-cells and APCs in transgenic (tg) mice models of AD-like cerebral amyloidosis. Increased numbers of infiltrating T-cells were found in amyloid-burdened brain regions of tg mice, with concomitant up-regulation of endothelial adhesion molecules ICAM-1 and VCAM-1, compared to non-tg littermates. The infiltrating T-cells in tg brains did not co-localise with amyloid plaques, produced less interferon-gamma than those in controls and did not proliferate locally. Bona-fide dendritic cells were virtually absent from the brain parenchyma of both non-tg and tg mice, and APCs from tg brains showed an immature phenotype, with accumulation of MHC-II in intracellular compartments. These results indicate that cerebral amyloidosis promotes T-cell infiltration but interferes with local antigen presentation and T-cell activation. The inability of the brain immune surveillance to orchestrate a protective immune response to amyloid-beta peptide might contribute to the accumulation of amyloid in the progression of the disease. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  9. [Detrusor sphincter disorders associated with deep endometriosis: Systematic review of the literature].

    PubMed

    Grouin, A; Florian, A; Sans Mischel, A C; Toullalan, O

    2018-01-01

    Detrusor sphincter disorders impact quality of life in case of deep endometriosis. Surgery, which is one of the main treatments, is responsible of detrusor sphincter disorders. Since then, it is essential to look for those disorders and find the right medical care. To specify the detrusor sphincter disorders, its links with anatomical localisation of deep endometriosis and its prognosis after surgery. A literature review was carried out via PubMed ® with the followings keywords: "deep endometriosis", "urinary disorders", "voiding dysfunction" and "urinary dysfunction". Prospective and retrospective studies as well as previous reviews were analyzed. Concerning bladder deep endometriosis, detrusor sphincter disorders are observed in more than 50%. Resection of the lesions allows a clear improvement or even a disappearance of the disorders. Concerning the deep endometriosis of the posterior part of the pelvis, disorders are highlighted even if women do not complain of urinary trouble. Detrusor sphincter disorders are observed in 2 to 50% and women with colorectal localisation have the highest rate. Resection of the lesions improves the symptoms described preoperatively but also provides de novo disorders of up to 47.5%. In terms of prevention, the nerve sparing surgery respects the pelvic nerve plexus, and reduces post-operative morbidity to less than 1%. Detrusor sphincter disorders associated with deep endometriosis have a prognosis if their management is adapted. Well-conducted interviews and standardized questionnaires is necessary to diagnosis them. Urodynamic test may be discussed in case of bladder endometriosis, including for urinary asymptomatic patients. The management of the detrusor sphincter disorders requires a complete resection of the nodules of deep endometriosis. In the case of posterior endometriosis, a dissection must be performed respecting the retroperitoneal vegetative nerves. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  10. A new TAO kinase inhibitor reduces tau phosphorylation at sites associated with neurodegeneration in human tauopathies.

    PubMed

    Giacomini, Caterina; Koo, Chuay-Yeng; Yankova, Natalia; Tavares, Ignatius A; Wray, Selina; Noble, Wendy; Hanger, Diane P; Morris, Jonathan D H

    2018-05-07

    In Alzheimer's disease (AD) and related tauopathies, the microtubule-associated protein tau is highly phosphorylated and aggregates to form neurofibrillary tangles that are characteristic of these neurodegenerative diseases. Our previous work has demonstrated that the thousand-and-one amino acid kinases (TAOKs) 1 and 2 phosphorylate tau on more than 40 residues in vitro. Here we show that TAOKs are phosphorylated and active in AD brain sections displaying mild (Braak stage II), intermediate (Braak stage IV) and advanced (Braak stage VI) tau pathology and that active TAOKs co-localise with both pre-tangle and tangle structures. TAOK activity is also enriched in pathological tau containing sarkosyl-insoluble extracts prepared from AD brain. Two new phosphorylated tau residues (T123 and T427) were identified in AD brain, which appear to be targeted specifically by TAOKs. A new small molecule TAOK inhibitor (Compound 43) reduced tau phosphorylation on T123 and T427 and also on additional pathological sites (S262/S356 and S202/T205/S208) in vitro and in cell models. The TAOK inhibitor also decreased tau phosphorylation in differentiated primary cortical neurons without affecting markers of synapse and neuron health. Notably, TAOK activity also co-localised with tangles in post-mortem frontotemporal lobar degeneration (FTLD) brain tissue. Furthermore, the TAOK inhibitor decreased tau phosphorylation in induced pluripotent stem cell derived neurons from FTLD patients, as well as cortical neurons from a transgenic mouse model of tauopathy (Tau35 mice). Our results demonstrate that abnormal TAOK activity is present at pre-tangles and tangles in tauopathies and that TAOK inhibition effectively decreases tau phosphorylation on pathological sites. Thus, TAOKs may represent a novel target to reduce or prevent tau-associated neurodegeneration in tauopathies.

  11. Electrically isolated, high melting point, metal wire arrays and method of making same

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Simpson, John T.; Cunningham, Joseph P.; D'Urso, Brian R.

    2016-01-26

    A method of making a wire array includes the step of providing a tube of a sealing material and having an interior surface, and positioning a wire in the tube, the wire having an exterior surface. The tube is heated to soften the tube, and the softened tube is drawn and collapsed by a mild vacuum to bring the interior surface of the tube into contact with the wire to create a coated wire. The coated wires are bundled. The bundled coated wires are heated under vacuum to fuse the tube material coating the wires and create a fused rodmore » with a wire array embedded therein. The fused rod is cut to form a wire array. A wire array is also disclosed.« less

  12. A novelty detection diagnostic methodology for gearboxes operating under fluctuating operating conditions using probabilistic techniques

    NASA Astrophysics Data System (ADS)

    Schmidt, S.; Heyns, P. S.; de Villiers, J. P.

    2018-02-01

    In this paper, a fault diagnostic methodology is developed which is able to detect, locate and trend gear faults under fluctuating operating conditions when only vibration data from a single transducer, measured on a healthy gearbox are available. A two-phase feature extraction and modelling process is proposed to infer the operating condition and based on the operating condition, to detect changes in the machine condition. Information from optimised machine and operating condition hidden Markov models are statistically combined to generate a discrepancy signal which is post-processed to infer the condition of the gearbox. The discrepancy signal is processed and combined with statistical methods for automatic fault detection and localisation and to perform fault trending over time. The proposed methodology is validated on experimental data and a tacholess order tracking methodology is used to enhance the cost-effectiveness of the diagnostic methodology.

  13. Giant mediastinal haemangiopericytoma: an uncommon case.

    PubMed

    Agrawal, D; Lahiri, T K; Lakhotia, S; Singh, Deepak

    2014-01-01

    Haemangiopericytoma is a rare soft tissue tumour characterised by tightly packed tumour cells situated around thin walled endothelial lined vascular channels, ranging from capillary sized vessels to large gaping sinusoidal spaces. The tumour cells are surrounded by reticulin and are negative for muscle, nerve and epithelial markers. The diagnosis of extra-pulmonary intra-thoracic, extra-pleural mediastinal mass is difficult. It constitutes only 6% of all primary tumours and cysts of the mediastinum. We report the rare occurrence of primary intra-thoracic, extra-pulmonary mediastinal haemangiopericytoma of mesenchymal origin with perivascular localisation. The patient underwent right postero-lateral thoracotomy and post-operatively received chemotherapy with adriamycin (60 mg/m2) on day 1 and ifosfamide (1.5 g/m2) on day 1 to 3. Thirty-seven months after the operation, the patient has been well with evidence of a single recurrence in the left lower lobe.

  14. Physiological volume regulation by spermatozoa.

    PubMed

    Yeung, C H; Barfield, J P; Cooper, T G

    2006-05-16

    Maturing spermatozoa passing through the epididymis experience increasing osmolality in the luminal environment and mature cells are stored in fluids hyper-osmotic to serum. When ejaculated into the female tract, they encounter a hypo-osmotic challenge which initiates the process of regulatory volume decrease (RVD). Defects in RVD result in hindrance of mucus penetration in man and failure of utero-tubal passage in mice. Epididymal sperm from the mouse and cynomolgus monkey and ejaculated sperm from man and monkey have been isolated and dispersed in media with osmolalities mimicking those of uterine fluid or cervical mucus. The effects of specific and broad-spectrum ion channel blockers indicate the involvement of separate K+ and Cl- channels as well as organic osmolytes in physiological sperm RVD, with mechanisms developed during epididymal maturation. Western blotting and immuno-cytochemistry identify and localise some of these channels which play a crucial role in fertilisation in vivo and could be targets for post-testicular contraception.

  15. Laser-induced fluorescence in malignant and normal tissue in mice injected with two different carotenoporphyrins.

    PubMed Central

    Nilsson, H.; Johansson, J.; Svanberg, K.; Svanberg, S.; Jori, G.; Reddi, E.; Segalla, A.; Gust, D.; Moore, A. L.; Moore, T. A.

    1994-01-01

    Laser-induced fluorescence (LIF) was used to characterise the localisation of an intravenously administered trimethylated carotenoporphyrin [CP(Me)3] and a trimethoxylated carotenoporphyrin [CP(OMe)3] in an intramuscularly transplanted malignant tumour (MS-2 fibrosarcoma) and healthy muscle in female Balb/c mice, 3, 24, 48 and 96 h post injection. The fluorescence was induced with a dye laser pumped by a nitrogen laser, emitting light at 425 nm. The fluorescence spectra were recorded in the region 455-760 nm using a polychromator equipped with an image-intensified CCD camera. The tumour/peritumoral muscle ratio was about 5:1 for CP(Me)3 and about 6:1 for CP(OMe)3 in terms of the background-free fluorescence intensity, which peaked at about 655 nm. By including the endogenous tissue fluorescence, the contrast was further enhanced by a factor of approximately 2. PMID:7947092

  16. Percutaneous foot joint needle placement using a C-arm flat-panel detector CT.

    PubMed

    Wiewiorski, Martin; Takes, Martin Thanh Long; Valderrabano, Victor; Jacob, Augustinus Ludwig

    2012-03-01

    Image guidance is valuable for diagnostic injections in foot orthopaedics. Flat-detector computed tomography (FD-CT) was implemented using a C-arm, and the system was tested for needle guidance in foot joint injections. FD-CT-guided joint infiltration was performed in 6 patients referred from the orthopaedic department for diagnostic foot injections. All interventions were performed utilising a flat-panel fluoroscopy system utilising specialised image guidance and planning software. Successful infiltration was defined by localisation of contrast media depot in the targeted joint. The pre- and post-interventional numeric analogue scale (NAS) pain score was assessed. All injections were technically successful. Contrast media deposit was documented in all targeted joints. Significant relief of symptoms was noted by all 6 participants. FD-CT-guided joint infiltration is a feasible method for diagnostic infiltration of midfoot and hindfoot joints. The FD-CT approach may become an alternative to commonly used 2D-fluoroscopically guidance.

  17. 49 CFR 234.241 - Protection of insulated wire; splice in underground wire.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Protection of insulated wire; splice in underground wire. 234.241 Section 234.241 Transportation Other Regulations Relating to Transportation... of insulated wire; splice in underground wire. Insulated wire shall be protected from mechanical...

  18. 49 CFR 234.241 - Protection of insulated wire; splice in underground wire.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Protection of insulated wire; splice in underground wire. 234.241 Section 234.241 Transportation Other Regulations Relating to Transportation... of insulated wire; splice in underground wire. Insulated wire shall be protected from mechanical...

  19. Wire-bonder-assisted integration of non-bondable SMA wires into MEMS substrates

    NASA Astrophysics Data System (ADS)

    Fischer, A. C.; Gradin, H.; Schröder, S.; Braun, S.; Stemme, G.; van der Wijngaart, W.; Niklaus, F.

    2012-05-01

    This paper reports on a novel technique for the integration of NiTi shape memory alloy wires and other non-bondable wire materials into silicon-based microelectromechanical system structures using a standard wire-bonding tool. The efficient placement and alignment functions of the wire-bonding tool are used to mechanically attach the wire to deep-etched silicon anchoring and clamping structures. This approach enables a reliable and accurate integration of wire materials that cannot be wire bonded by traditional means.

  20. 30 CFR 75.517 - Power wires and cables; insulation and protection.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Power wires and cables; insulation and...-General § 75.517 Power wires and cables; insulation and protection. [Statutory Provisions] Power wires and cables, except trolley wires, trolley feeder wires, and bare signal wires, shall be insulated adequately...

  1. 30 CFR 75.517 - Power wires and cables; insulation and protection.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Power wires and cables; insulation and...-General § 75.517 Power wires and cables; insulation and protection. [Statutory Provisions] Power wires and cables, except trolley wires, trolley feeder wires, and bare signal wires, shall be insulated adequately...

  2. 30 CFR 75.517 - Power wires and cables; insulation and protection.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Power wires and cables; insulation and...-General § 75.517 Power wires and cables; insulation and protection. [Statutory Provisions] Power wires and cables, except trolley wires, trolley feeder wires, and bare signal wires, shall be insulated adequately...

  3. 30 CFR 75.517 - Power wires and cables; insulation and protection.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Power wires and cables; insulation and...-General § 75.517 Power wires and cables; insulation and protection. [Statutory Provisions] Power wires and cables, except trolley wires, trolley feeder wires, and bare signal wires, shall be insulated adequately...

  4. 77 FR 17418 - Galvanized Steel Wire From the People's Republic of China: Final Affirmative Countervailing Duty...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-26

    ... DEPARTMENT OF COMMERCE International Trade Administration [C-570-976] Galvanized Steel Wire From... exporters of galvanized steel wire (galvanized wire) from the People's Republic of China (the PRC). For... investigation are Davis Wire Corporation, Johnstown Wire Technologies, Inc., Mid- South Wire Company, Inc...

  5. 30 CFR 75.517 - Power wires and cables; insulation and protection.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Power wires and cables; insulation and...-General § 75.517 Power wires and cables; insulation and protection. [Statutory Provisions] Power wires and cables, except trolley wires, trolley feeder wires, and bare signal wires, shall be insulated adequately...

  6. Orbiter Kapton wire operational requirements and experience

    NASA Technical Reports Server (NTRS)

    Peterson, R. V.

    1994-01-01

    The agenda of this presentation includes the Orbiter wire selection requirements, the Orbiter wire usage, fabrication and test requirements, typical wiring installations, Kapton wire experience, NASA Kapton wire testing, summary, and backup data.

  7. Sub-cellular localisation studies may spuriously detect the Yes-associated protein, YAP, in nucleoli leading to potentially invalid conclusions of its function.

    PubMed

    Finch, Megan L; Passman, Adam M; Strauss, Robyn P; Yeoh, George C; Callus, Bernard A

    2015-01-01

    The Yes-associated protein (YAP) is a potent transcriptional co-activator that functions as a nuclear effector of the Hippo signaling pathway. YAP is oncogenic and its activity is linked to its cellular abundance and nuclear localisation. Activation of the Hippo pathway restricts YAP nuclear entry via its phosphorylation by Lats kinases and consequent cytoplasmic retention bound to 14-3-3 proteins. We examined YAP expression in liver progenitor cells (LPCs) and surprisingly found that transformed LPCs did not show an increase in YAP abundance compared to the non-transformed LPCs from which they were derived. We then sought to ascertain whether nuclear YAP was more abundant in transformed LPCs. We used an antibody that we confirmed was specific for YAP by immunoblotting to determine YAP's sub-cellular localisation by immunofluorescence. This antibody showed diffuse staining for YAP within the cytosol and nuclei, but, noticeably, it showed intense staining of the nucleoli of LPCs. This staining was non-specific, as shRNA treatment of cells abolished YAP expression to undetectable levels by Western blot yet the nucleolar staining remained. Similar spurious YAP nucleolar staining was also seen in mouse embryonic fibroblasts and mouse liver tissue, indicating that this antibody is unsuitable for immunological applications to determine YAP sub-cellular localisation in mouse cells or tissues. Interestingly nucleolar staining was not evident in D645 cells suggesting the antibody may be suitable for use in human cells. Given the large body of published work on YAP in recent years, many of which utilise this antibody, this study raises concerns regarding its use for determining sub-cellular localisation. From a broader perspective, it serves as a timely reminder of the need to perform appropriate controls to ensure the validity of published data.

  8. Sub-Cellular Localisation Studies May Spuriously Detect the Yes-Associated Protein, YAP, in Nucleoli Leading to Potentially Invalid Conclusions of Its Function

    PubMed Central

    Finch, Megan L.; Passman, Adam M.; Strauss, Robyn P.; Yeoh, George C.; Callus, Bernard A.

    2015-01-01

    The Yes-associated protein (YAP) is a potent transcriptional co-activator that functions as a nuclear effector of the Hippo signaling pathway. YAP is oncogenic and its activity is linked to its cellular abundance and nuclear localisation. Activation of the Hippo pathway restricts YAP nuclear entry via its phosphorylation by Lats kinases and consequent cytoplasmic retention bound to 14-3-3 proteins. We examined YAP expression in liver progenitor cells (LPCs) and surprisingly found that transformed LPCs did not show an increase in YAP abundance compared to the non-transformed LPCs from which they were derived. We then sought to ascertain whether nuclear YAP was more abundant in transformed LPCs. We used an antibody that we confirmed was specific for YAP by immunoblotting to determine YAP’s sub-cellular localisation by immunofluorescence. This antibody showed diffuse staining for YAP within the cytosol and nuclei, but, noticeably, it showed intense staining of the nucleoli of LPCs. This staining was non-specific, as shRNA treatment of cells abolished YAP expression to undetectable levels by Western blot yet the nucleolar staining remained. Similar spurious YAP nucleolar staining was also seen in mouse embryonic fibroblasts and mouse liver tissue, indicating that this antibody is unsuitable for immunological applications to determine YAP sub-cellular localisation in mouse cells or tissues. Interestingly nucleolar staining was not evident in D645 cells suggesting the antibody may be suitable for use in human cells. Given the large body of published work on YAP in recent years, many of which utilise this antibody, this study raises concerns regarding its use for determining sub-cellular localisation. From a broader perspective, it serves as a timely reminder of the need to perform appropriate controls to ensure the validity of published data. PMID:25658431

  9. A core outcome set for localised prostate cancer effectiveness trials: protocol for a systematic review of the literature and stakeholder involvement through interviews and a Delphi survey.

    PubMed

    MacLennan, Steven; Bekema, Hendrika J; Williamson, Paula R; Campbell, Marion K; Stewart, Fiona; MacLennan, Sara J; N'Dow, James M O; Lam, Thomas B L

    2015-03-04

    Prostate cancer is a growing health problem worldwide. The management of localised prostate cancer is controversial. It is unclear which of several surgical, radiotherapeutic, ablative, and surveillance treatments is the most effective. All have cost, process and recovery, and morbidity implications which add to treatment decision-making complexity for patients and healthcare professionals. Evidence from randomised controlled trials (RCTs) is not optimal because of uncertainty as to what constitutes important outcomes. Another issue hampering evidence synthesis is heterogeneity of outcome definition, measurement, and reporting. This project aims to determine which outcomes are the most important to patients and healthcare professionals, and use these findings to recommend a standardised core outcome set for comparative effectiveness trials of treatments for localised prostate cancer, to optimise decision-making. The range of potentially important outcomes and measures will be identified through systematic reviews of the literature and semi-structured interviews with patients. A consultation exercise involving representatives from two key stakeholder groups (patients and healthcare professionals) will ratify the list of outcomes to be entered into a three round Delphi study. The Delphi process will refine and prioritise the list of identified outcomes. A methodological substudy (nested RCT design) will also be undertaken. Participants will be randomised after round one of the Delphi study to one of three feedback groups, based on different feedback strategies, in order to explore the potential impact of feedback strategies on participant responses. This may assist the design of a future core outcome set and Delphi studies. Following the Delphi study, a final consensus meeting attended by representatives from both stakeholder groups will determine the final recommended core outcome set. This study will inform clinical practice and future trials of interventions of localised prostate cancer by standardising a core outcome set which should be considered in comparative effectiveness studies for localised prostate cancer.

  10. Proteins encoded by the gerP operon are localised to the inner coat in Bacilluscereus spores and are dependent on GerPA and SafA for assembly.

    PubMed

    Ghosh, Abhinaba; Manton, James D; Mustafa, Amin R; Gupta, Mudit; Ayuso-Garcia, Alejandro; Rees, Eric J; Christie, Graham

    2018-05-04

    Germination of Bacillus spores is triggered by certain amino acids and sugar molecules, which permeate through the outermost layers of the spore to interact with receptor complexes that reside in the inner membrane. Previous studies have shown that mutations in the hexacistronic gerP locus reduce the rate of spore germination, with experimental evidence indicating that the defect stems from reduced permeability of the spore coat to germinant molecules. Here we use the ellipsoid localisation microscopy technique to reveal that all six Bacillus cereus GerP proteins share proximity with cortex lytic enzymes within the inner coat. We reveal also that the GerPA protein alone can localise in the absence of all other GerP proteins, and that it has an essential role for the localisation of all other GerP proteins within the spore. The latter is also demonstrated to be SafA - but not CotE - dependent for localisation, which is consistent with an inner coat location. GerP null spores are shown also to have reduced permeability to fluorescently labelled dextran molecules compared to wild type spores. Overall, the results support the hypothesis that the GerP proteins have a structural role within the spore associated with coat permeability. Importance The bacterial spore coat comprises a multi-layered proteinaceous structure that influences the distribution, survival and germination properties of spores in the environment. Results from the current study are significant since they increase our understanding of coat assembly and architecture while adding detail to existing models of germination. We demonstrate also that the ELM image analysis technique can be used as a novel tool to provide direct quantitative measurements of spore coat permeability. Progress in all of these areas should ultimately facilitate improved methods of spore control in a range of industrial, healthcare and environmental sectors. Copyright © 2018 American Society for Microbiology.

  11. Heat shock protein 27 is a potential indicator for response to YangZheng XiaoJi and chemotherapy agents in cancer cells.

    PubMed

    Owen, Sioned; Zhao, Huishan; Dart, Alwyn; Wang, Yamei; Ruge, Fiona; Gao, Yong; Wei, Cong; Wu, Yiling; Jiang, Wen G

    2016-11-01

    Heat shock protein 27 (HSP27) is a member of the heat shock protein family which has been linked to tumour progression and, most interestingly, to chemotherapy resistance in cancer patients. The present study examined the potential interplay between HSP27 and YangZheng XiaoJi, a traditional Chinese medicine used in cancer treatment. A range of cell lines from different tumour types including pancreatic, lung, gastric, colorectal, breast, prostate and ovarian cancer (both wild-type and resistant) were used. Levels and activation of HSP27 and its potential associated signalling pathways were evaluated by protein array and western blotting. Knockdown of HSP27 in cancer cells was achieved using siRNA. Localisation and co-localisation of HSP27 and other proteins were carried out by immunofluorescence. Cell growth and migration were evaluated in their response to a range of chemotherapeutic agents. The present study first identified, by way of protein array, that YangZheng XiaoJi was able to inhibit the phosphorylation of HSP27 protein in cancer cells. We further demonstrated that HSP27, which is co-localised with caspase-9, can be blocked from localising in focal adhesions and co-localising with caspase-9 by YangZheng XiaoJi. The study also demonstrated that YangZheng XiaoJi was able to sensitise cancer cells including those cells that were resistant to chemotherapy, to chemotherapeutic agents. Finally, knocking down HSP27 markedly reduced the migration of cancer cells and increased the sensitivity of cancer cells to the inhibitory effect on cellular migration by YangZheng XiaoJi. YangZheng XiaoJi can act as an agent in first sensitising cancer cells to chemotherapy and secondly to overcome, to some degree, chemoresistance when used in an appropriate fashion in patients who have active HSP27.

  12. Autonomous localisation of rovers for future planetary exploration

    NASA Astrophysics Data System (ADS)

    Bajpai, Abhinav

    Future Mars exploration missions will have increasingly ambitious goals compared to current rover and lander missions. There will be a need for extremely long distance traverses over shorter periods of time. This will allow more varied and complex scientific tasks to be performed and increase the overall value of the missions. The missions may also include a sample return component, where items collected on the surface will be returned to a cache in order to be returned to Earth, for further study. In order to make these missions feasible, future rover platforms will require increased levels of autonomy, allowing them to operate without heavy reliance on a terrestrial ground station. Being able to autonomously localise the rover is an important element in increasing the rover's capability to independently explore. This thesis develops a Planetary Monocular Simultaneous Localisation And Mapping (PM-SLAM) system aimed specifically at a planetary exploration context. The system uses a novel modular feature detection and tracking algorithm called hybrid-saliency in order to achieve robust tracking, while maintaining low computational complexity in the SLAM filter. The hybrid saliency technique uses a combination of cognitive inspired saliency features with point-based feature descriptors as input to the SLAM filter. The system was tested on simulated datasets generated using the Planetary, Asteroid and Natural scene Generation Utility (PANGU) as well as two real world datasets which closely approximated images from a planetary environment. The system was shown to provide a higher accuracy of localisation estimate than a state-of-the-art VO system tested on the same data set. In order to be able to localise the rover absolutely, further techniques are investigated which attempt to determine the rover's position in orbital maps. Orbiter Mask Matching uses point-based features detected by the rover to associate descriptors with large features extracted from orbital imagery and stored in the rover memory prior the mission launch. A proof of concept is evaluated using a PANGU simulated boulder field.

  13. An isolated dorso-medial dislocation of navicular bone: A case report.

    PubMed

    Singh, Varun Kumar; Kashyap, Abhishek; Vargaonkar, Gauresh; Kumar, Ramesh

    2015-03-01

    An isolated dislocation of tarsal navicular is extremely rare injury. Usually it is associated with fracture of navicular itself or other tarsal bones of foot along with disruption of medial or lateral column of foot. Mechanism of injury is complex but usually a severe abduction force is required to produce such injury in a planter flexed foot. A 30 year old male presented with isolated navicular dislocation. Management required open reduction and fixation with k-wires. These injuries have specific complications including avascular necrosis of navicular and post-traumatic arthritis.

  14. Representative Command Post Configurations, C3 Structures, and Reference Data. Volume I.

    DTIC Science & Technology

    1978-07-31

    when it becomes cost effective. (4) The configurations and employment concepts can be used for electronic warfare (EW) studies. The detailed layouts...TJI/0! 0, LIKAS INFCCOPERATOR mmTmOE1110"m - -.- an SKI WeI TIpO .o..< - UN THAN do Ma uSIm TIo a D CIM 1 0 ~To NtEN INTRABATTERY WIRE COMMUNICATIONS...34 DE ATTACH/ GIVARO I TTRY -IVARTY ATTACH/ A I A COMG REINF COMO SOC TOC NEW ITRY I (WO NTE 21O (NOTE 21 UNITS FCC FOC FCIR NOTES: I. COUNTERMORTAR

  15. Mechanical Behavior of Three-Dimensional Braided Nickel-Based Superalloys Synthesized via Pack Cementation

    NASA Astrophysics Data System (ADS)

    Lippitz, Nicolas; Erdeniz, Dinc; Sharp, Keith W.; Dunand, David C.

    2018-03-01

    Braided tubes of Ni-based superalloys are fabricated via three-dimensional (3-D) braiding of ductile Ni-20Cr (wt pct) wires followed by post-textile gas-phase alloying with Al and Ti to create, after homogenization and aging, γ/ γ' strengthened lightweight, porous structures. Tensile tests reveal an increase in strength by 100 MPa compared to as-braided Ni-20Cr (wt pct). An interrupted tensile test, combined with X-ray tomographic scans between each step, sheds light on the failure behavior of the braided superalloy tubes.

  16. Simulation of future global warming scenarios in rice paddies with an open-field warming facility

    PubMed Central

    2011-01-01

    To simulate expected future global warming, hexagonal arrays of infrared heaters have previously been used to warm open-field canopies of upland crops such as wheat. Through the use of concrete-anchored posts, improved software, overhead wires, extensive grounding, and monitoring with a thermal camera, the technology was safely and reliably extended to paddy rice fields. The system maintained canopy temperature increases within 0.5°C of daytime and nighttime set-point differences of 1.3 and 2.7°C 67% of the time. PMID:22145582

  17. Semiconductor bridge (SCB) detonator

    DOEpatents

    Bickes, Jr., Robert W.; Grubelich, Mark C.

    1999-01-01

    The present invention is a low-energy detonator for high-density secondary-explosive materials initiated by a semiconductor bridge igniter that comprises a pair of electrically conductive lands connected by a semiconductor bridge. The semiconductor bridge is in operational or direct contact with the explosive material, whereby current flowing through the semiconductor bridge causes initiation of the explosive material. Header wires connected to the electrically-conductive lands and electrical feed-throughs of the header posts of explosive devices, are substantially coaxial to the direction of current flow through the SCB, i.e., substantially coaxial to the SCB length.

  18. 30 CFR 75.701-4 - Grounding wires; capacity of wires.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Grounding wires; capacity of wires. 75.701-4... SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Grounding § 75.701-4 Grounding wires; capacity of wires. Where grounding wires are used to ground metallic sheaths, armors, conduits, frames...

  19. 30 CFR 75.701-4 - Grounding wires; capacity of wires.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Grounding wires; capacity of wires. 75.701-4... SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Grounding § 75.701-4 Grounding wires; capacity of wires. Where grounding wires are used to ground metallic sheaths, armors, conduits, frames...

  20. 29 CFR 1915.118 - Tables.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Improved Plow Steel, Independent Wire Rope Core, Wire Rope and Wire Rope Slings [In tons of 2,000 pounds... for Improved Plow Steel, Independent Wire Rope Core, Wire Rope Slings [in tons of 2,000 pounds] Two...-4—Rated Capacities for Improved Plow Steel, Fiber Core, Wire Rope and Wire Rope Slings [in tons of 2...

  1. 29 CFR 1915.118 - Tables.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Improved Plow Steel, Independent Wire Rope Core, Wire Rope and Wire Rope Slings [In tons of 2,000 pounds... for Improved Plow Steel, Independent Wire Rope Core, Wire Rope Slings [in tons of 2,000 pounds] Two...-4—Rated Capacities for Improved Plow Steel, Fiber Core, Wire Rope and Wire Rope Slings [in tons of 2...

  2. Characterization of copper and nichrome wires for safety fuse

    NASA Astrophysics Data System (ADS)

    Murdani, E.

    2016-11-01

    Fuse is an important component of an electrical circuit to limiting the current through the electrical circuit for electrical equipment safety. Safety fuses are made of a conductor such as copper and nichrome wires. The aim of this research was to determine the maximum current that can flow in the conductor wires (copper and nichrome). In the experiment used copper and nichrome wires by varying the length of wires (0.2 cm to 20 cm) and diameter of wires (0.1, 0.2, 0.3, 0.4 and 0.5) mm until maximum current reached that marked by melted or broken wire. From this experiment, it will be obtained the dependences data of maximum current to the length and diameter of wires. All data are plotted and it's known as a standard curve. The standard curve will provide an alternative choice of replacing fuse wire according to the maximum current requirement, including the wire type (copper and nichrome wires) and wire dimensions (length and diameter of wire).

  3. Length-dependent structural stability of linear monatomic Cu wires

    NASA Astrophysics Data System (ADS)

    Singh, Gurvinder; Kumar, Krishan; Singh, Baljinder; Moudgil, R. K.

    2018-05-01

    We present first-principle calculations based on density functional theory for the finite-length monatomic Cu atom linear wires. The structure and its stability with increasing wire length in terms of number of atoms (N) is determined. Interestingly, the bond length is found to exhibit an oscillatory structure (the so-called magic length phenomenon), with a qualitative change in oscillatory behavior as one moves from even N wire to odd N wire. The even N wires follow simple even-odd oscillations whereas odd N wires show a phase change at the half length of the wires. The stability of the wire structure, determined in terms of the wire formation energy, also contains even-odd oscillation as a function of wire length. However, the oscillations in formation energy reverse its phase after the wire length is increased beyond N=12. Our findings are seen to be qualitatively consistent with recent simulations for a similar class finite-length metal atom wires.

  4. Patella Fracture Fixation with Suture and Wire: you Reap what you Sew

    PubMed Central

    Egol, Kenneth; Howard, Daniel; Monroy, Alexa; Crespo, Alexander; Tejwani, Nirmal; Davidovitch, Roy

    2014-01-01

    Introduction Operative fixation of displaced inferior pole patella fractures has now become the standard of care. This study aims to quantify clinical, radiographic and functional outcomes, as well as identify complications in a cohort of patients treated with non-absorbable braided suture fixation for inferior pole patellar fractures. These patients were then compared to a control group of patients treated for mid-pole fractures with K-wires or cannulated screws with tension band wiring. Methods In this IRB approved study, we identified a cohort of patients who were diagnosed and treated surgically for a displaced patella fracture. Demographic, injury, and surgical information were recorded. All patients were treated with a standard surgical technique utilizing non-absorbable braided suture woven through the patellar tendon and placed through drill holes to achieve reduction and fracture fixation. All patients were treated with a similar post-operative protocol and followed up at standard intervals. Data were collected concurrently at follow up visits. For purpose of comparison, we identified a control cohort with middle third patella fractures treated with either k-wires or cannulated screws and tension band technique. Patients were followed by the treating surgeon at regular follow-up intervals. Outcomes included self-reported function and knee range of motion compared to the uninjured side. Results Forty-nine patients with 49 patella fractures identified retrospectively were treated over 9 years. This cohort consisted of 31 females (63.3%) and 18 males (36.7%) with an average age of 57.1 years (range 26 - 88 years). Patients had an average BMI of 26.48 (range 19 - 44.08). Thirteen patients with inferior pole fractures underwent suture fixation and 36 patients with mid-pole fractures underwent tension band fixation (K-wire or cannulated screws with tension band). In the suture cohort, one fracture failed open repair (7.6%), which was revised again with sutures and progressed to union. Of the 36 fractures repaired with a tension band fixation, 11 underwent secondary surgery due to hardware pain or fixation failure (30.6%). At one year, no difference was seen in knee range of motion between cohorts. All fractures healed radiographically. Those patients who required reoperation or removal of hardware had significantly diminished range of motion about their injured knee (p > 0.005). Conclusions Patients who sustain inferior pole patella fractures have limited options for fracture fixation. Suture repair is clinically acceptable, yielding similar results to patella fractures repaired with metal implants. Importantly, patients undergoing suture repair appear to have fewer hardware related postoperative complications than those receiving wire fixation for midpole fractures. PMID:25328461

  5. Patella fracture fixation with suture and wire: you reap what you sew.

    PubMed

    Egol, Kenneth; Howard, Daniel; Monroy, Alexa; Crespo, Alexander; Tejwani, Nirmal; Davidovitch, Roy

    2014-01-01

    Operative fixation of displaced inferior pole patella fractures has now become the standard of care. This study aims to quantify clinical, radiographic and functional outcomes, as well as identify complications in a cohort of patients treated with non-absorbable braided suture fixation for inferior pole patellar fractures. These patients were then compared to a control group of patients treated for mid-pole fractures with K-wires or cannulated screws with tension band wiring. In this IRB approved study, we identified a cohort of patients who were diagnosed and treated surgically for a displaced patella fracture. Demographic, injury, and surgical information were recorded. All patients were treated with a standard surgical technique utilizing non-absorbable braided suture woven through the patellar tendon and placed through drill holes to achieve reduction and fracture fixation. All patients were treated with a similar post-operative protocol and followed up at standard intervals. Data were collected concurrently at follow up visits. For purpose of comparison, we identified a control cohort with middle third patella fractures treated with either k-wires or cannulated screws and tension band technique. Patients were followed by the treating surgeon at regular follow-up intervals. Outcomes included self-reported function and knee range of motion compared to the uninjured side. Forty-nine patients with 49 patella fractures identified retrospectively were treated over 9 years. This cohort consisted of 31 females (63.3%) and 18 males (36.7%) with an average age of 57.1 years (range 26-88 years). Patients had an average BMI of 26.48 (range 19-44.08). Thirteen patients with inferior pole fractures underwent suture fixation and 36 patients with mid-pole fractures underwent tension band fixation (K-wire or cannulated screws with tension band). In the suture cohort, one fracture failed open repair (7.6%), which was revised again with sutures and progressed to union. Of the 36 fractures repaired with a tension band fixation, 11 underwent secondary surgery due to hardware pain or fixation failure (30.6%). At one year, no difference was seen in knee range of motion between cohorts. All fractures healed radiographically. Those patients who required reoperation or removal of hardware had significantly diminished range of motion about their injured knee (p > 0.005). Patients who sustain inferior pole patella fractures have limited options for fracture fixation. Suture repair is clinically acceptable, yielding similar results to patella fractures repaired with metal implants. Importantly, patients undergoing suture repair appear to have fewer hardware related postoperative complications than those receiving wire fixation for midpole fractures.

  6. Biofilm formation on stainless steel and gold wires for bonded retainers in vitro and in vivo and their susceptibility to oral antimicrobials.

    PubMed

    Jongsma, Marije A; Pelser, Floris D H; van der Mei, Henny C; Atema-Smit, Jelly; van de Belt-Gritter, Betsy; Busscher, Henk J; Ren, Yijin

    2013-05-01

    Bonded retainers are used in orthodontics to maintain treatment result. Retention wires are prone to biofilm formation and cause gingival recession, bleeding on probing and increased pocket depths near bonded retainers. In this study, we compare in vitro and in vivo biofilm formation on different wires used for bonded retainers and the susceptibility of in vitro biofilms to oral antimicrobials. Orthodontic wires were exposed to saliva, and in vitro biofilm formation was evaluated using plate counting and live/dead staining, together with effects of exposure to toothpaste slurry alone or followed by antimicrobial mouthrinse application. Wires were also placed intra-orally for 72 h in human volunteers and undisturbed biofilm formation was compared by plate counting and live/dead staining, as well as by denaturing gradient gel electrophoresis for compositional differences in biofilms. Single-strand wires attracted only slightly less biofilm in vitro than multi-strand wires. Biofilms on stainless steel single-strand wires however, were much more susceptible to antimicrobials from toothpaste slurries and mouthrinses than on single-strand gold wires and biofilms on multi-strand wires. Also, in vivo significantly less biofilm was found on single-strand than on multi-strand wires. Microbial composition of biofilms was more dependent on the volunteer involved than on wire type. Biofilms on single-strand stainless steel wires attract less biofilm in vitro and are more susceptible to antimicrobials than on multi-strand wires. Also in vivo, single-strand wires attract less biofilm than multi-strand ones. Use of single-strand wires is preferred over multi-strand wires, not because they attract less biofilm, but because biofilms on single-strand wires are not protected against antimicrobials as in crevices and niches as on multi-strand wires.

  7. Referee Networks and Their Spectral Properties

    NASA Astrophysics Data System (ADS)

    Slanina, F.; Zhang, Y.-Ch.

    2005-09-01

    The bipartite graph connecting products and reviewers of that product is studied empirically in the case of amazon.com. We find that the network has power-law degree distribution on the side of reviewers, while on the side of products the distribution is better fitted by stretched exponential. The spectrum of normalised adjacency matrix shows power-law tail in the density of states. Establishing the community structures by finding localised eigenstates is not straightforward as the localised and delocalised states are mixed throughout the whole support of the spectrum.

  8. Equation of state and electron localisation in fcc lithium

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Frost, Mungo; Levitan, Abraham L.; Sun, Peihao

    We present an improved equation of state for the high-pressure fcc phase of lithium with ambient temperature experimental data, extending the pressure range of previous studies to 36 GPa. Accompanying density functional theory calculations, which reproduce the experimental equation of state, show that with increasing density the phase diverges from a nearly free electron metal. At the high pressure limit of its stability fcc lithium exhibits enhanced electron density on the octahedral interstices with a high degree of localisation.

  9. Equation of state and electron localisation in fcc lithium

    DOE PAGES

    Frost, Mungo; Levitan, Abraham L.; Sun, Peihao; ...

    2018-02-14

    We present an improved equation of state for the high-pressure fcc phase of lithium with ambient temperature experimental data, extending the pressure range of previous studies to 36 GPa. Accompanying density functional theory calculations, which reproduce the experimental equation of state, show that with increasing density the phase diverges from a nearly free electron metal. At the high pressure limit of its stability fcc lithium exhibits enhanced electron density on the octahedral interstices with a high degree of localisation.

  10. 46 CFR 111.60-11 - Wire.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Wire. 111.60-11 Section 111.60-11 Shipping COAST GUARD... Wiring Materials and Methods § 111.60-11 Wire. (a) Wire must be in an enclosure. (b) Wire must be component insulated. (c) Wire, other than in switchboards, must meet the requirements in sections 24.6.7 and...

  11. 46 CFR 111.60-11 - Wire.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Wire. 111.60-11 Section 111.60-11 Shipping COAST GUARD... Wiring Materials and Methods § 111.60-11 Wire. (a) Wire must be in an enclosure. (b) Wire must be component insulated. (c) Wire, other than in switchboards, must meet the requirements in sections 24.6.7 and...

  12. Development of a pin-post insulator with built-in metal oxide varistors for distribution lines

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fujiwara, N.; Yoneyama, T.; Hamada, Y.

    1996-04-01

    A 6.6 kV pin-post insulator, incorporating ZnO varistors, has been developed in order to reduce line faults caused by direct lighting strikes, thereby reducing and simplifying maintenance work on distribution systems. The developed insulators are interchangeable with conventional pin insulators and can withstand internal fault currents twice upon their failures. The simulated results regarding the response of the developed insulators to direct lightning strikes on an overhead ground wire agreed well with the experimental results. Simulation studies also revealed that installing the developed insulators on every two poles reduces the line-fault rate of present distribution lines in case of directmore » lightning strikes by 33%, while installing them on every pole reduces the rate by 97.5% or about 1/40 of the original value.« less

  13. EM calibration based on Post OPC layout analysis

    NASA Astrophysics Data System (ADS)

    Sreedhar, Aswin; Kundu, Sandip

    2010-03-01

    Design for Manufacturability (DFM) involves changes to the design and CAD tools to help increase pattern printability and improve process control. Design for Reliability (DFR) performs the same to improve reliability of devices from failures such as Electromigration (EM), gate-oxide break down, hot carrier injection (HCI), Negative Bias Temperature Insatiability (NBTI) and mechanical stress effects. Electromigration (EM) occurs due to migration or displacement of atoms as a result of the movement of electrons through a conducting medium. The rate of migration determines the Mean Time to Failure (MTTF) which is modeled as a function of temperature and current density. The model itself is calibrated through failure analysis (FA) of parts that are deemed to have failed due to EM against design parameters such as linewidth. Reliability Verification (RV) of a design involves verifying that every conducting line in a design meets certain MTTF threshold. In order to perform RV, current density for each wire must be computed. Current itself is a function of the parasitics that are determined through RC extraction. The standard practice is to perform the RC extraction and current density calculation on drawn, pre-OPC layouts. If a wire fails to meet threshold for MTTF, it may be resized. Subsequently, mask preparation steps such as OPC and PSM introduce extra features such as SRAFs, jogs,hammerheads and serifs that change their resistance, capacitance and current density values. Hence, calibrating EM model based on pre-OPC layouts will lead to different results compared to post-OPC layouts. In this work, we compare EM model calibration and reliability check based on drawn layout versus predicted layout, where the drawn layout is pre-OPC layout and predicted layout is based on litho simulation of post-OPC layout. Results show significant divergence between these two approaches, making a case for methodology based on predicted layout.

  14. Influence of bolt tightening torque, wire size, and component reuse on wire fixation in circular external fixation.

    PubMed

    Wosar, Marc A; Marcellin-Little, Denis J; Roe, Simon C

    2002-01-01

    To evaluate the effects of bolt torque, wire size, and component reuse on the ability to maintain wire tension in 3 external skeletal fixation systems. Biomechanical study. Yield strength in tension of 1.0-, 1.2-, 1.5-, and 1.6-mm-diameter wires, and yield strength in torque of Hofmann Small Bone Fixation (SBF) cannulated and slotted bolts and IMEX regular and miniature bolts were determined on a testing machine. The minimum bolt tightening torque needed to prevent wire slippage at clinically recommended wire tensions was determined. Components were tested 10 times, and loads at slippage were recorded. The IMEX system required a mean of 8 Nm of bolt tightening torque to maintain 900 N (1.6-mm wires). The SBF system required a mean of 3 Nm bolt torque to maintain 300 N (1.0-mm wires) and 5 Nm to maintain 600 N (1.2-mm wires). The SBF cannulated bolt required 9 Nm of torque to maintain 900 N (1.5-mm wires). The SBF slotted bolts could only maintain 800 N before yield. The IMEX miniature system required a mean bolt torque of 1.1 Nm to maintain 300 N. The cannulated and slotted bolts from both manufacturers failed to maintain 70% of initial wire tension after 7 and 4 uses, respectively. The IMEX systems and the SBF system using 1.0- and 1.2-mm wires could maintain clinically recommended wire tension safely. Only the IMEX system could maintain clinically recommended wire tension safely using 1.5- or 1.6-mm wires. The SBF system using 1.0- and 1.2-mm wires and the IMEX system using all wire sizes can maintain clinically relevant wire tension. The SBF system using 1.5-mm wires could not. Cannulated and slotted bolts should not be used more than 6 and 3 times, respectively. Nuts should not be reused. Copyright 2002 by The American College of Veterinary Surgeons

  15. 49 CFR 236.71 - Signal wires on pole line and aerial cable.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Signal wires on pole line and aerial cable. 236.71... Instructions: All Systems Wires and Cables § 236.71 Signal wires on pole line and aerial cable. Signal wire on... pole or other support. Signal wire shall not interfere with, or be interfered by, other wires on the...

  16. 49 CFR 236.71 - Signal wires on pole line and aerial cable.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Signal wires on pole line and aerial cable. 236.71... Instructions: All Systems Wires and Cables § 236.71 Signal wires on pole line and aerial cable. Signal wire on... pole or other support. Signal wire shall not interfere with, or be interfered by, other wires on the...

  17. Atom chips in the real world: the effects of wire corrugation

    NASA Astrophysics Data System (ADS)

    Schumm, T.; Estève, J.; Figl, C.; Trebbia, J.-B.; Aussibal, C.; Nguyen, H.; Mailly, D.; Bouchoule, I.; Westbrook, C. I.; Aspect, A.

    2005-02-01

    We present a detailed model describing the effects of wire corrugation on the trapping potential experienced by a cloud of atoms above a current carrying micro wire. We calculate the distortion of the current distribution due to corrugation and then derive the corresponding roughness in the magnetic field above the wire. Scaling laws are derived for the roughness as a function of height above a ribbon shaped wire. We also present experimental data on micro wire traps using cold atoms which complement some previously published measurements [CITE] and which demonstrate that wire corrugation can satisfactorily explain our observations of atom cloud fragmentation above electroplated gold wires. Finally, we present measurements of the corrugation of new wires fabricated by electron beam lithography and evaporation of gold. These wires appear to be substantially smoother than electroplated wires.

  18. Exercising calf muscle T₂∗ changes correlate with pH, PCr recovery and maximum oxidative phosphorylation.

    PubMed

    Schmid, Albrecht Ingo; Schewzow, Kiril; Fiedler, Georg Bernd; Goluch, Sigrun; Laistler, Elmar; Wolzt, Michael; Moser, Ewald; Meyerspeer, Martin

    2014-05-01

    Skeletal muscle metabolism is impaired in disorders like diabetes mellitus or peripheral vascular disease. The skeletal muscle echo planar imaging (EPI) signal (S(EPI) ) and its relation to energy metabolism are still debated. Localised ³¹P MRS and S(EPI) data from gastrocnemius medialis of 19 healthy subjects were combined in one scanning session to study direct relationships between phosphocreatine (PCr), pH kinetics and parameters of T₂∗ time courses. Dynamic spectroscopy (semi-LASER) and EPI were performed immediately before, during and after 5 min of plantar flexions. Data were acquired in a 7 T MR scanner equipped with a custom-built ergometer and a dedicated ³¹P/¹H radio frequency (RF) coil array. Using a form-fitted multi-channel ³¹P/¹H coil array resulted in high signal-to-noise ratio (SNR). PCr and pH in the gastrocnemius medialis muscle were quantified from each ³¹P spectrum, acquired every 6 s. During exercise, SEPI (t) was found to be a linear function of tissue pH(t) (cross-correlation r = -0.85 ± 0.07). Strong Pearson's correlations were observed between post exercise time-to-peak (TTP) of SEPI and (a) the time constant of PCr recovery τPCr recovery (r = 0.89, p < 10⁻⁶), (b) maximum oxidative phosphorylation using the linear model, Q(max, lin) (r = 0.65, p = 0.002), the adenosine-diphosphate-driven model, Q(max,ADP) (r = 0.73, p = 0.0002) and (c) end exercise pH (r = 0.60, p = 0.005). Based on combined accurately localised ³¹P MRS and T₂∗ weighted MRI, both with high temporal resolution, strong correlations of the skeletal muscle SEPI during exercise and tissue pH time courses and of post exercise SEPI and parameters of energy metabolism were observed. In conclusion, a tight coupling between skeletal muscle metabolic activity and tissue T₂∗ signal weighting, probably induced by osmotically driven water shift, exists and can be measured non-invasively, using NMR at 7 T. © 2014 The Authors. NMR in Biomedicine published by John Wiley & Sons, Ltd.

  19. wannier90: A tool for obtaining maximally-localised Wannier functions

    NASA Astrophysics Data System (ADS)

    Mostofi, Arash A.; Yates, Jonathan R.; Lee, Young-Su; Souza, Ivo; Vanderbilt, David; Marzari, Nicola

    2008-05-01

    We present wannier90, a program for calculating maximally-localised Wannier functions (MLWF) from a set of Bloch energy bands that may or may not be attached to or mixed with other bands. The formalism works by minimising the total spread of the MLWF in real space. This is done in the space of unitary matrices that describe rotations of the Bloch bands at each k-point. As a result, wannier90 is independent of the basis set used in the underlying calculation to obtain the Bloch states. Therefore, it may be interfaced straightforwardly to any electronic structure code. The locality of MLWF can be exploited to compute band-structure, density of states and Fermi surfaces at modest computational cost. Furthermore, wannier90 is able to output MLWF for visualisation and other post-processing purposes. Wannier functions are already used in a wide variety of applications. These include analysis of chemical bonding in real space; calculation of dielectric properties via the modern theory of polarisation; and as an accurate and minimal basis set in the construction of model Hamiltonians for large-scale systems, in linear-scaling quantum Monte Carlo calculations, and for efficient computation of material properties, such as the anomalous Hall coefficient. wannier90 is freely available under the GNU General Public License from http://www.wannier.org/. Program summaryProgram title: wannier90 Catalogue identifier: AEAK_v1_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/AEAK_v1_0.html Program obtainable from: CPC Program Library, Queen's University, Belfast, N. Ireland Licensing provisions: Standard CPC licence, http://cpc.cs.qub.ac.uk/licence/licence.html No. of lines in distributed program, including test data, etc.: 556 495 No. of bytes in distributed program, including test data, etc.: 5 709 419 Distribution format: tar.gz Programming language: Fortran 90, perl Computer: any architecture with a Fortran 90 compiler Operating system: Linux, Windows, Solaris, AIX, Tru64 Unix, OSX RAM: 10 MB Word size: 32 or 64 Classification: 7.3 External routines:BLAS ( http://www/netlib.org/blas). LAPACK ( http://www.netlib.org/lapack). Both available under open-source licenses. Nature of problem: Obtaining maximally-localised Wannier functions from a set of Bloch energy bands that may or may not be entangled. Solution method: In the case of entangled bands, the optimally-connected subspace of interest is determined by minimising a functional which measures the subspace dispersion across the Brillouin zone. The maximally-localised Wannier functions within this subspace are obtained by subsequent minimisation of a functional that represents the total spread of the Wannier functions in real space. For the case of isolated energy bands only the second step of the procedure is required. Unusual features: Simple and user-friendly input system. Wannier functions and interpolated band structure output in a variety of file formats for visualisation. Running time: Test cases take 1 minute. References:N. Marzari, D. Vanderbilt, Maximally localized generalized Wannier functions for composite energy bands, Phys. Rev. B 56 (1997) 12847. I. Souza, N. Marzari, D. Vanderbilt, Maximally localized Wannier functions for entangled energy bands, Phys. Rev. B 65 (2001) 035109.

  20. Acquisition of Turbulence Data Using the DST Group Constant-Temperature Hot-Wire Anemometer System

    DTIC Science & Technology

    2015-10-01

    fluctuations in the low-speed wind tunnel at DST Group. The use of both single- wire and crossed- wire (2 wire ) probes is described. Areas covered include a...fluid-flow studies, including testing of models of aircraft, ships and submarines in wind and water tunnels. Hot- wire anemometers and associated hot...spectra of velocity fluctuations in the low-speed wind tunnel at DST Group. The use of both single- wire and crossed- wire (2 wires ) probes is

  1. Integrating the Gradient of the Thin Wire Kernel

    NASA Technical Reports Server (NTRS)

    Champagne, Nathan J.; Wilton, Donald R.

    2008-01-01

    A formulation for integrating the gradient of the thin wire kernel is presented. This approach employs a new expression for the gradient of the thin wire kernel derived from a recent technique for numerically evaluating the exact thin wire kernel. This approach should provide essentially arbitrary accuracy and may be used with higher-order elements and basis functions using the procedure described in [4].When the source and observation points are close, the potential integrals over wire segments involving the wire kernel are split into parts to handle the singular behavior of the integrand [1]. The singularity characteristics of the gradient of the wire kernel are different than those of the wire kernel, and the axial and radial components have different singularities. The characteristics of the gradient of the wire kernel are discussed in [2]. To evaluate the near electric and magnetic fields of a wire, the integration of the gradient of the wire kernel needs to be calculated over the source wire. Since the vector bases for current have constant direction on linear wire segments, these integrals reduce to integrals of the form

  2. Automatic segmentation of stereoelectroencephalography (SEEG) electrodes post-implantation considering bending.

    PubMed

    Granados, Alejandro; Vakharia, Vejay; Rodionov, Roman; Schweiger, Martin; Vos, Sjoerd B; O'Keeffe, Aidan G; Li, Kuo; Wu, Chengyuan; Miserocchi, Anna; McEvoy, Andrew W; Clarkson, Matthew J; Duncan, John S; Sparks, Rachel; Ourselin, Sébastien

    2018-06-01

    The accurate and automatic localisation of SEEG electrodes is crucial for determining the location of epileptic seizure onset. We propose an algorithm for the automatic segmentation of electrode bolts and contacts that accounts for electrode bending in relation to regional brain anatomy. Co-registered post-implantation CT, pre-implantation MRI, and brain parcellation images are used to create regions of interest to automatically segment bolts and contacts. Contact search strategy is based on the direction of the bolt with distance and angle constraints, in addition to post-processing steps that assign remaining contacts and predict contact position. We measured the accuracy of contact position, bolt angle, and anatomical region at the tip of the electrode in 23 post-SEEG cases comprising two different surgical approaches when placing a guiding stylet close to and far from target point. Local and global bending are computed when modelling electrodes as elastic rods. Our approach executed on average in 36.17 s with a sensitivity of 98.81% and a positive predictive value (PPV) of 95.01%. Compared to manual segmentation, the position of contacts had a mean absolute error of 0.38 mm and the mean bolt angle difference of [Formula: see text] resulted in a mean displacement error of 0.68 mm at the tip of the electrode. Anatomical regions at the tip of the electrode were in strong concordance with those selected manually by neurosurgeons, [Formula: see text], with average distance between regions of 0.82 mm when in disagreement. Our approach performed equally in two surgical approaches regardless of the amount of electrode bending. We present a method robust to electrode bending that can accurately segment contact positions and bolt orientation. The techniques presented in this paper will allow further characterisation of bending within different brain regions.

  3. Nox2 Knockout Delays Infarct Progression and Increases Vascular Recovery through Angiogenesis in Mice following Ischaemic Stroke with Reperfusion

    PubMed Central

    McCann, Sarah K.; Dusting, Gregory J.; Roulston, Carli L.

    2014-01-01

    Evidence suggests the NADPH oxidases contribute to ischaemic stroke injury and Nox2 is the most widely studied subtype in the context of stroke. There is still conjecture however regarding the benefits of inhibiting Nox2 to improve stroke outcome. The current study aimed to examine the temporal effects of genetic Nox2 deletion on neuronal loss after ischaemic stroke using knockout (KO) mice with 6, 24 and 72 hour recovery. Transient cerebral ischaemia was induced via intraluminal filament occlusion and resulted in reduced infarct volumes in Nox2 KO mice at 24 h post-stroke compared to wild-type controls. No protection was evident at either 6 h or 72 h post-stroke, with both genotypes exhibiting similar volumes of damage. Reactive oxygen species were detected using dihydroethidium and were co-localised with neurons and microglia in both genotypes using immunofluorescent double-labelling. The effect of Nox2 deletion on vascular damage and recovery was also examined 24 h and 72 h post-stroke using an antibody against laminin. Blood vessel density was decreased in the ischaemic core of both genotypes 24 h post-stroke and returned to pre-stroke levels only in Nox2 KO mice by 72 h. Overall, these results are the first to show that genetic Nox2 deletion merely delays the progression of neuronal loss after stroke but does not prevent it. Additionally, we show for the first time that Nox2 deletion increases re-vascularisation of the damaged brain by 72 h, which may be important in promoting endogenous brain repair mechanisms that rely on re-vascularisation. PMID:25375101

  4. Fracture Energy-Based Brittleness Index Development and Brittleness Quantification by Pre-peak Strength Parameters in Rock Uniaxial Compression

    NASA Astrophysics Data System (ADS)

    Munoz, H.; Taheri, A.; Chanda, E. K.

    2016-12-01

    Brittleness is a fundamental mechanical rock property critical to many civil engineering works, mining development projects and mineral exploration operations. However, rock brittleness is a concept yet to be investigated as there is not any unique criterion available, widely accepted by rock engineering community able to describe rock brittleness quantitatively. In this study, new brittleness indices were developed based on fracture strain energy quantities obtained from the complete stress-strain characteristics of rocks. In doing so, different rocks having unconfined compressive strength values ranging from 7 to 215 MPa were examined in a series of quasi-static uniaxial compression tests after properly implementing lateral-strain control in a closed-loop system to apply axial load to rock specimen. This testing method was essential to capture post-peak regime of the rocks since a combination of class I-II or class II behaviour featured post-peak stress-strain behaviour. Further analysis on the post-peak strain localisation, stress-strain characteristics and the fracture pattern causing class I-II and class II behaviour were undertaken by analysing the development of field of strains in the rocks via three-dimensional digital image correlation. Analysis of the results demonstrated that pre-peak stress-strain brittleness indices proposed solely based on pre-peak stress-strain behaviour do not show any correlation with any of pre-peak rock mechanical parameters. On the other hand, the proposed brittleness indices based on pre-peak and post-peak stress-strain relations were found to competently describe an unambiguous brittleness scale against rock deformation and strength parameters such as the elastic modulus, the crack damage stress and the peak stress relevant to represent failure process.

  5. An Obstacle Alerting System for Agricultural Application

    NASA Technical Reports Server (NTRS)

    DeMaio, Joe

    2003-01-01

    Wire strikes are a significant cause of helicopter accidents. The aircraft most at risk are aerial applicators. The present study examines the effectiveness of a wire alert delivered by way of the lightbar, a GPS-based guidance system for aerial application. The alert lead-time needed to avoid an invisible wire is compared with that to avoid a visible wire. A flight simulator was configured to simulate an agricultural application helicopter. Two pilots flew simulated spray runs in fields with visible wires, invisible wires, and no wires. The wire alert was effective in reducing wire strikes. A lead-time of 3.5 sec was required for the alert to be effective. The lead- time required was the same whether the pilot could see the wire or not.

  6. Fabrication of fine-grain tantalum diffusion barrier tube for Nb3Sn conductors

    NASA Astrophysics Data System (ADS)

    Hartwig, K. T.; Balachandran, S.; Mezyenski, R.; Seymour, N.; Robinson, J.; Barber, R. E.

    2014-01-01

    Diffusion barriers used in Nb3Sn wire are often fabricated by wrapping Ta sheet into a tube with an overlap seam. A common result of such practice is non-uniform deformation in the Ta sheet as it thins by wire drawing because of non-uniform grain size and texture in the original Ta sheet. Seamless Ta tube with a fine-grain and uniform microstructure would be much better for the diffusion barrier application, but such material is expensive and difficult to manufacture. This report presents results on a new fabrication strategy for Ta tube that shows promise for manufacture of less costly tube with an improved microstructure. The fabrication method begins with seam-welded tube but gives a fine-grain uniform microstructure with little difference between the longitudinal seam weld region and the parent metal after post-weld processing. Severe plastic deformation processing (SPD) applied by area reduction extrusion and tube equal channel angular extrusion (tECAE) are used to refine and homogenize the microstructure. Microstructure and mechanical property results are presented for Ta tubes fabricated by this new processing strategy.

  7. Method and apparatus for improved wire saw slurry

    DOEpatents

    Costantini, Michael A.; Talbott, Jonathan A.; Chandra, Mohan; Prasad, Vishwanath; Caster, Allison; Gupta, Kedar P.; Leyvraz, Philippe

    2000-09-05

    A slurry recycle process for use in free-abrasive machining operations such as for wire saws used in wafer slicing of ingots, where the used slurry is separated into kerf-rich and abrasive-rich components, and the abrasive-rich component is reconstituted into a makeup slurry. During the process, the average particle size of the makeup slurry is controlled by monitoring the condition of the kerf and abrasive components and making necessary adjustments to the separating force and dwell time of the separator apparatus. Related pre-separator and post separator treatments, and feedback of one or the other separator slurry output components for mixing with incoming used slurry and recirculation through the separator, provide further effectiveness and additional control points in the process. The kerf-rich component is eventually or continually removed; the abrasive-rich component is reconstituted into a makeup slurry with a controlled, average particle size such that the products of the free-abrasive machining method using the recycled slurry process of the invention are of consistent high quality with less TTV deviation from cycle to cycle for a prolonged period or series of machining operations.

  8. Electric and Magnetic Manipulation of Biological Systems

    NASA Astrophysics Data System (ADS)

    Lee, H.; Hunt, T. P.; Liu, Y.; Ham, D.; Westervelt, R. M.

    2005-06-01

    New types of biological cell manipulation systems, a micropost matrix, a microelectromagnet matrix, and a microcoil array, were developed. The micropost matrix consists of post-shaped electrodes embedded in an insulating layer. With a separate ac voltage applied to each electrode, the micropost matrix generates dielectrophoretic force to trap and move individual biological cells. The microelectromagnet matrix consists of two arrays of straight wires aligned perpendicular to each other, that are covered with insulating layers. By independently controlling the current in each wire, the microelectromagnet matrix creates versatile magnetic fields to manipulate individual biological cells attached to magnetic beads. The microcoil array is a set of coils implemented in a foundry using a standard silicon fabrication technology. Current sources to the coils, and control circuits are integrated on a single chip, making the device self-contained. Versatile manipulation of biological cells was demonstrated using these devices by generating optimized electric or magnetic field patterns. A single yeast cell was trapped and positioned with microscopic resolution, and multiple yeast cells were trapped and independently moved along the separate paths for cell-sorting.

  9. Plant immune and growth receptors share common signalling components but localise to distinct plasma membrane nanodomains.

    PubMed

    Bücherl, Christoph A; Jarsch, Iris K; Schudoma, Christian; Segonzac, Cécile; Mbengue, Malick; Robatzek, Silke; MacLean, Daniel; Ott, Thomas; Zipfel, Cyril

    2017-03-06

    Cell surface receptors govern a multitude of signalling pathways in multicellular organisms. In plants, prominent examples are the receptor kinases FLS2 and BRI1, which activate immunity and steroid-mediated growth, respectively. Intriguingly, despite inducing distinct signalling outputs, both receptors employ common downstream signalling components, which exist in plasma membrane (PM)-localised protein complexes. An important question is thus how these receptor complexes maintain signalling specificity. Live-cell imaging revealed that FLS2 and BRI1 form PM nanoclusters. Using single-particle tracking we could discriminate both cluster populations and we observed spatiotemporal separation between immune and growth signalling platforms. This finding was confirmed by visualising FLS2 and BRI1 within distinct PM nanodomains marked by specific remorin proteins and differential co-localisation with the cytoskeleton. Our results thus suggest that signalling specificity between these pathways may be explained by the spatial separation of FLS2 and BRI1 with their associated signalling components within dedicated PM nanodomains.

  10. [Morphea or juvenile localised scleroderma: Case report].

    PubMed

    Strickler, Alexis; Gallo, Silvanna; Jaramillo, Pedro; de Toro, Gonzalo

    2016-01-01

    Morphea or juvenile localised scleroderma (JLS) is an autoimmune, inflammatory, chronic, slowly progressive connective tissue disease of unknown cause that preferably affects skin and underlying tissues. To report a case of Juvenil Localised scleroderma in an 8-year old girl, contributing to an early diagnosis and treatment. The case is presented of an 8 year-old girl who presented with indurated hypopigmented plaques, of linear distribution in the right upper extremity of two years onset, together with papery texture hyperpigmented indurated plaques with whitish areas of thinned skin in right lower extremity, and leg and ankle swelling. The clinical features and diagnostic tests, including histology were compatible with linear and pansclerotic JLS. She started with immunosuppressive therapy, physiotherapy, and occupational therapy. We report a case of linear and pansclerotic ELJ type, in which there was a 2 year delay in diagnosis, however the response to treatment was positive as expected. Copyright © 2016 Sociedad Chilena de Pediatría. Publicado por Elsevier España, S.L.U. All rights reserved.

  11. Modelling impacts and recovery in benthic communities exposed to localised high CO2.

    PubMed

    Lessin, Gennadi; Artioli, Yuri; Queirós, Ana M; Widdicombe, Stephen; Blackford, Jerry C

    2016-08-15

    Regulations pertaining to carbon dioxide capture with offshore storage (CCS) require an understanding of the potential localised environmental impacts and demonstrably suitable monitoring practices. This study uses a marine ecosystem model to examine a comprehensive range of hypothetical CO2 leakage scenarios, quantifying both impact and recovery time within the benthic system. Whilst significant mortalities and long recovery times were projected for the larger and longer term scenarios, shorter-term or low level exposures lead to reduced projected impacts. This suggests that efficient monitoring and leak mitigation strategies, coupled with appropriate selection of storage sites can effectively limit concerns regarding localised environmental impacts from CCS. The feedbacks and interactions between physiological and ecological responses simulated reveal that benthic responses to CO2 leakage could be complex. This type of modelling investigation can aid the understanding of impact potential, the role of benthic community recovery and inform the design of baseline and monitoring surveys. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Come rain or shine? Public expectation on local weather change and differential effects on climate change attitude.

    PubMed

    Lo, Alex Y; Jim, C Y

    2015-11-01

    Tailored messages are instrumental to climate change communication. Information about the global threat can be 'localised' by demonstrating its linkage with local events. This research ascertains the relationship between climate change attitude and perception of local weather, based on a survey involving 800 Hong Kong citizens. Results indicate that concerns about climate change increase with expectations about the likelihood and impacts of local weather change. Climate change believers attend to all three types of adverse weather events, namely, temperature rises, tropical cyclones and prolonged rains. Climate scepticism, however, is not associated with expectation about prolonged rains. Differential spatial orientations are a possible reason. Global climate change is an unprecedented and distant threat, whereas local rain is a more familiar and localised weather event. Global climate change should be articulated in terms that respect local concerns. Localised framing may be particularly effective for engaging individuals holding positive views about climate change science. © The Author(s) 2014.

  13. "Blindsight" and subjective awareness of fearful faces: Inversion reverses the deficits in fear perception associated with core psychopathic traits.

    PubMed

    Oliver, Lindsay D; Mao, Alexander; Mitchell, Derek G V

    2015-01-01

    Though emotional faces preferentially reach awareness, the present study utilised both objective and subjective indices of awareness to determine whether they enhance subjective awareness and "blindsight". Under continuous flash suppression, participants localised a disgusted, fearful or neutral face (objective index), and rated their confidence (subjective index). Psychopathic traits were also measured to investigate their influence on emotion perception. As predicted, fear increased localisation accuracy, subjective awareness and "blindsight" of upright faces. Coldhearted traits were inversely related to subjective awareness, but not "blindsight", of upright fearful faces. In a follow-up experiment using inverted faces, increased localisation accuracy and awareness, but not "blindsight", were observed for fear. Surprisingly, awareness of inverted fearful faces was positively correlated with coldheartedness. These results suggest that emotion enhances both pre-conscious processing and the qualitative experience of awareness, but that pre-conscious and conscious processing of emotional faces rely on at least partially dissociable cognitive mechanisms.

  14. A Review of Non-Invasive Techniques to Detect and Predict Localised Muscle Fatigue

    PubMed Central

    Al-Mulla, Mohamed R.; Sepulveda, Francisco; Colley, Martin

    2011-01-01

    Muscle fatigue is an established area of research and various types of muscle fatigue have been investigated in order to fully understand the condition. This paper gives an overview of the various non-invasive techniques available for use in automated fatigue detection, such as mechanomyography, electromyography, near-infrared spectroscopy and ultrasound for both isometric and non-isometric contractions. Various signal analysis methods are compared by illustrating their applicability in real-time settings. This paper will be of interest to researchers who wish to select the most appropriate methodology for research on muscle fatigue detection or prediction, or for the development of devices that can be used in, e.g., sports scenarios to improve performance or prevent injury. To date, research on localised muscle fatigue focuses mainly on the clinical side. There is very little research carried out on the implementation of detecting/predicting fatigue using an autonomous system, although recent research on automating the process of localised muscle fatigue detection/prediction shows promising results. PMID:22163810

  15. [Clinical epidemiological assessments on 3521 patients suffering from road traffic injuries, in relation with trauma localisation and severity, assisted in "Sf. Ioan" Emergency Unit, during 2002-2009].

    PubMed

    Manole, M; Ciuhodaru, T; Zanoschi, Georgeta; Manole, Alina; Ivan, A

    2011-01-01

    The aim of study was to assess road traffic injuries in relation with their localisation and severity. A sample of 3521 patients suffering from road traffic injuries and assisted in "Sf. Ioan" Emergency Unit, Iaşi, Romania was assess regarding age group, sex and residence area, type of lesions and ther localisation and severity, between 2002-2009. Data were collected using a special epidemiological inquiry and processed using SPSS and MS Excel statistical softs. The incidence of road traffic injuries increased during the last decade, with a report men/women of 1.5, urban and 21-30 age group predominance. The most frequent were leg fractures (16.7%) and thoracal contusions (19.1%), cranial and facial trauma (32.4%), with open injuries (10.5%). Prevention programmes with a high efficiency at the national level, as well as a concret identification of risk factors with a multidisciplinar approach of road traffic accidents, are needed.

  16. Suppression of Red Luminescence in Wire Explosion Derived Eu:ZnO

    NASA Astrophysics Data System (ADS)

    Pallavi, Bandi; Sathyan, Sneha; Yoshimura, Takuya; Kumar, Praveen; Anbalagan, Kousika; Talluri, Bhusankar; Ramanujam, Sarathi; Ranjan, Prem; Thomas, Tiju

    2018-03-01

    Europium oxide (Eu2O3) is coated on zinc (Zn) wire using the electrophoretic deposition process. The coated Zn wire is subjected to the wire explosion process (WEP) which is rapid (< 15 min), and chimie douce (soft chemical, low temperature), in nature; this results in the formation of Eu doped ZnO. The explosion chamber contains oxygen (99.9%) at atmospheric pressure. Electron micrographs indicate that the particle sizes are ˜ 80 nm. Diffractogram-based analysis suggests that the crystallite size is 18-20 nm in the as-prepared doped ZnO nanoparticles. Electron paramagnetic resonance shows the presence of Zn vacancies and the cryo-photoluminescence spectrum indicates that Eu exists in the + 3 state. A combined Williamson-Hall plot and Kisielowski's model based analysis indicates that Eu is a substitutional dopant in WEP derived Eu:ZnO particles. It is estimated that this material has ˜ 0.24 at.% doping. This analysis also shows that, unlike another popular material GaN, in the case of ZnO, Eu3+ strictly substitutes for Zn2+ (i.e., dopant replacing a cation-anion pair does not seem possible). It may be noted that Eu3+ in a suitable host is oftentimes reported to be an efficient luminophore. The IR spectra show a band shift from 486 cm-1 to 493 cm-1; with peak shifts from 436 cm-1 to 430 cm-1 in Raman spectra. These too indicate the presence of Eu in the samples. However, at room temperature, only green luminescence (centered at 534 nm) is observed from the sample indicating (1) high concentrations of OZn anti-site defects and Zn vacancies, and (2) concomitant quenching of the luminescence at room temperature. Our results suggest that WEP is viable for synthesizing rare earth doped ceramic materials. However, obtaining efficient phosphors using this approach will likely require, (1) reduction of defect densities, and (2) appropriate passivation using post-processing.

  17. The importance of carbon nanotube wire density, structural uniformity, and purity for fabricating homogeneous carbon nanotube-copper wire composites by copper electrodeposition

    NASA Astrophysics Data System (ADS)

    Sundaram, Rajyashree; Yamada, Takeo; Hata, Kenji; Sekiguchi, Atsuko

    2018-04-01

    We present the influence of density, structural regularity, and purity of carbon nanotube wires (CNTWs) used as Cu electrodeposition templates on fabricating homogeneous high-electrical performance CNT-Cu wires lighter than Cu. We show that low-density CNTWs (<0.6 g/cm3 for multiwall nanotube wires) with regular macro- and microstructures and high CNT content (>90 wt %) are essential for making homogeneous CNT-Cu wires. These homogeneous CNT-Cu wires show a continuous Cu matrix with evenly mixed nanotubes of high volume fractions (˜45 vol %) throughout the wire-length. Consequently, the composite wires show densities ˜5.1 g/cm3 (33% lower than Cu) and electrical conductivities ˜6.1 × 104 S/cm (>100 × CNTW conductivity). However, composite wires from templates with higher densities or structural inconsistencies are non-uniform with discontinuous Cu matrices and poor CNT/Cu mixing. These non-uniform CNT-Cu wires show conductivities 2-6 times lower than the homogeneous composite wires.

  18. Incidence of Treatment for Infection of Buried Versus Exposed Kirschner Wires in Phalangeal, Metacarpal, and Distal Radial Fractures.

    PubMed

    Ridley, Taylor J; Freking, Will; Erickson, Lauren O; Ward, Christina Marie

    2017-07-01

    To determine whether there is a difference in the incidence of infection between exposed and buried K-wires when used to treat phalangeal, metacarpal, and distal radius fractures. We conducted a retrospective review identifying all patients aged greater than 16 years who underwent fixation of phalangeal, metacarpal, or distal radius fractures with K-wires between 2007 and 2015. We recorded patient demographic data, fracture location, number of K-wires used, whether K-wires were buried or left exposed, and duration of K-wire placement. A total of 695 patients met inclusion criteria. Surgeons buried K-wires in 207 patients and left K-wires exposed in 488. Infections occurred more frequently in exposed K-wire cases than in buried K-wire ones. Subgroup analysis based on fracture location revealed a significantly increased risk of being treated for infection when exposed K-wires were used for metacarpal fractures. Patients with exposed K-wires for fixation of phalangeal, metacarpal, or distal radius fractures were more likely to be treated for a pin-site infection than those with K-wires buried beneath the skin. Metacarpal fractures treated with exposed K-wires were 2 times more likely to be treated for a pin-site infection (17.6% of exposed K wire cases vs 8.7% of buried K wire cases). Therapeutic IV. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  19. Research regarding stiffness optimization of wires used for joints actuation from an elephant's trunk robotic arm

    NASA Astrophysics Data System (ADS)

    Ciofu, C.; Stan, G.

    2016-11-01

    Elephant's trunk robotic arms driven by wires and pulley mechanisms have issues with wires stiffness because of the entailed elastic deformations that is causing errors of positioning. Static and dynamic loads from each joint of the robotic arm affect the stiffness of driving wires and precision positioning. The influence of wires elastic deformation on precision positioning decreases with the increasing of wires stiffness by using different pre-tensioning devices. In this paper, we analyze the variation of driving wires stiffness particularly to each wire driven joint. We obtain optimum wires stiffness variation by using an analytical method that highlights the efficiency of pre-tensioning mechanism. The analysis of driving wires stiffness is necessary for taking appropriate optimization measures of robotic arm dynamic behavior and, thus, for decreasing positioning errors of the elephant's trunk robotic arm with inner actuation through wires/cables.

  20. Hydrogen in Mono-Atomic Gold Wires

    NASA Astrophysics Data System (ADS)

    Barnett, Robert N.; Sherbakov, Andrew G.; Landman, Uzi; Hakkinen, Hannu

    2004-03-01

    Results of ab-initio scalar relativistic density functional calculations of the interaction between a mono-atomic gold wire (suspended between two gold tips) and a hydrogen molecule, at various stages of wire stretching, are presented. The hydrogen molecule does not bind to the wire until the wire is sufficiently stretched, i.e. starting to break, at which time the molecule inserts itself into the wire restoring a fraction of the conductance quantum g. With subsequent compression of the wire the axis of the molecule gradually tips away from the wire axis until it becomes "quasi-dissociated" with the H-H axis perpendicular to the wire. At this point the conductance almost vanishes, while for the bare wire the conductance at this tip-to-tip separation is close to 1g. These results, and the frequency of various vibrational modes of the hydrogen molecule, are compared with recent experimental and theoretical work involving platinum wires.

  1. 1 mil gold bond wire study.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huff, Johnathon; McLean, Michael B.; Jenkins, Mark W.

    2013-05-01

    In microcircuit fabrication, the diameter and length of a bond wire have been shown to both affect the current versus fusing time ratio of a bond wire as well as the gap length of the fused wire. This study investigated the impact of current level on the time-to-open and gap length of 1 mil by 60 mil gold bond wires. During the experiments, constant current was provided for a control set of bond wires for 250ms, 410ms and until the wire fused; non-destructively pull-tested wires for 250ms; and notched wires. The key findings were that as the current increases, themore » gap length increases and 73% of the bond wires will fuse at 1.8A, and 100% of the wires fuse at 1.9A within 60ms. Due to the limited scope of experiments and limited data analyzed, further investigation is encouraged to confirm these observations.« less

  2. 47 CFR 76.802 - Disposition of cable home wiring.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Cable Inside Wiring § 76.802 Disposition of cable home wiring... alternative video programming service provider connects its wiring to the home wiring before the incumbent... alternative video programming service provider shall be responsible for ensuring that the incumbent's wiring...

  3. Comparison of three different orthodontic wires for bonded lingual retainer fabrication

    PubMed Central

    Uysal, Tancan; Gul, Nisa; Alan, Melike Busra; Ramoglu, Sabri Ilhan

    2012-01-01

    Objective We evaluated the detachment force, amount of deformation, fracture mode, and pull-out force of 3 different wires used for bonded lingual retainer fabrication. Methods We tested 0.0215-inch five-stranded wire (PentaOne, Masel; group I), 0.016 × 0.022-inch dead-soft eight-braided wire (Bond-A-Braid, Reliance; group II), and 0.0195-inch dead-soft coaxial wire (Respond, Ormco; group III). To test detachment force, deformation, and fracture mode, we embedded 94 lower incisor teeth in acrylic blocks in pairs. Retainer wires were bonded to the teeth and vertically directed force was applied to the wire. To test pull-out force, wires were embedded in composite that was placed in a hole at the center of an acrylic block. Tensile force was applied along the long axis of the wire. Results Detachment force and mode of fracture were not different between groups. Deformation was significantly higher in groups II and III than in group I (p < 0.001). Mean pull-out force was significantly higher for group I compared to groups II and III (p < 0.001). Conclusions Detachment force and fracture mode were similar for all wires, but greater deformations were seen in dead-soft wires. Wire pull-out force was significantly higher for five-stranded coaxial wire than for the other wires tested. Five-stranded coaxial wires are suggested for use in bonded lingual retainers. PMID:23112930

  4. Real-time loudness normalisation with combined cochlear implant and hearing aid stimulation

    PubMed Central

    Van Eeckhoutte, Maaike; Van Deun, Lieselot; Francart, Tom

    2018-01-01

    Background People who use a cochlear implant together with a contralateral hearing aid—so-called bimodal listeners—have poor localisation abilities and sounds are often not balanced in loudness across ears. In order to address the latter, a loudness balancing algorithm was created, which equalises the loudness growth functions for the two ears. The algorithm uses loudness models in order to continuously adjust the two signals to loudness targets. Previous tests demonstrated improved binaural balance, improved localisation, and better speech intelligibility in quiet for soft phonemes. In those studies, however, all stimuli were preprocessed so spontaneous head movements and individual head-related transfer functions were not taken into account. Furthermore, the hearing aid processing was linear. Study design In the present study, we simplified the acoustical loudness model and implemented the algorithm in a real-time system. We tested bimodal listeners on speech perception and on sound localisation, both in normal loudness growth configuration and in a configuration with a modified loudness growth function. We also used linear and compressive hearing aids. Results The comparison between the original acoustical loudness model and the new simplified model showed loudness differences below 3% for almost all tested speech-like stimuli and levels. We found no effect of balancing the loudness growth across ears for speech perception ability in quiet and in noise. We found some small improvements in localisation performance. Further investigation with a larger sample size is required. PMID:29617421

  5. Quantification and in situ localisation of abcb1 and abcc9genes in toxicant-exposed sea urchin embryos.

    PubMed

    Bošnjak, Ivana; Pleić, Ivana Lepen; Borra, Marco; Mladineo, Ivona

    2013-12-01

    A multixenobiotic resistance (MXR) mechanism mediated by ABC binding cassette (ABC) transport proteins is an efficient chemical defence mechanism in sea urchin embryos. The aim of our work was to evidence whether exposure to sub-lethal doses of specific contaminants (oxybenzone (OXI), mercuric chloride (HgCl2) and trybutiltin (TBT)) would induce MXR transporter activity during embryonic development (from zygote to blastula stage) in purple sea urchin (Paracentrotus lividus) embryos. Further, we present data on molecular identification, transport function, expression levels and gene localisation of two ABC efflux transporters-P-glycoprotein (ABCB1/P-gp) and sulfonylurea-receptor-like protein (ABCC9/SUR-like). Partial cDNA sequences of abcb1 and abcc9 were identified and quantitative PCR (qPCR) evidenced an increase in mRNA transcript levels of both ABC transporters during the two-cell, as well as an overall decrease during the blastulae stage. Calcein-AM efflux activity assay indicated the activation of multidrug resistance-associated protein/ABCC-like transport in the presence of HgCl2 and TBT in exposed blastulae. The in situ hybridisation of the two-cell and blastula stages showed ubiquitous localisation of both transcripts within cells, supporting qPCR data. In conclusion, ABCB1 and ABCC9 are constitutive, as are HgCl2, TBT and OXI-inducible ABC membrane transporters, coexpressed in the zygote, two-cell and blastula stages of the P. lividus. Their ubiquitous cell localisation further fortifies their protective role in early embryonic development.

  6. Localised Nonlinear Waves in the Three-Component Coupled Hirota Equations

    NASA Astrophysics Data System (ADS)

    Xu, Tao; Chen, Yong

    2017-10-01

    We construct the Lax pair and Darboux transformation for the three-component coupled Hirota equations including higher-order effects such as third-order dispersion, self-steepening, and stimulated Raman scattering. A special vector solution of the Lax pair with 4×4 matrices for the three-component Hirota system is elaborately generated, based on this vector solution, various types of mixed higher-order localised waves are derived through the generalised Darboux transformation. Instead of considering various arrangements of the three potential functions q1, q2, and q3, here, the same combination is considered as the same type solution. The first- and second-order localised waves are mainly discussed in six mixed types: (1) the hybrid solutions degenerate to the rational ones and three components are all rogue waves; (2) two components are hybrid solutions between rogue wave (RW) and breather (RW+breather), and one component is interactional solution between RW and dark soliton (RW+dark soliton); (3) two components are RW+dark soliton, and one component is RW+bright soliton; (4) two components are RW+breather, and one component is RW+bright soliton; (5) two components are RW+dark soliton, and one component is RW+bright soliton; (6) three components are all RW+breather. Moreover, these nonlinear localised waves merge with each other by increasing the absolute values of two free parameters α, β. These results further uncover some striking dynamic structures in the multicomponent coupled system.

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tunbak, Hale, E-mail: h.tunbak@ucl.ac.uk; Georgiou, Christiana, E-mail: christiana.georgiou.10@ucl.ac.uk; Guan, Cui, E-mail: c.guan@qmul.ac.uk

    PRDM4 is a member of the PRDM family of transcriptional regulators which control various aspects of cellular differentiation and proliferation. PRDM proteins exert their biological functions both in the cytosol and the nucleus of cells. All PRDM proteins are characterised by the presence of two distinct structural motifs, the PR/SET domain and the zinc finger (ZF) motifs. We previously observed that deletion of all six zinc fingers found in PRDM4 leads to its accumulation in the cytosol, whereas overexpressed full length PRDM4 is found predominantly in the nucleus. Here, we investigated the requirements for single zinc fingers in the nuclearmore » localisation of PRDM4. We demonstrate that ZF's 1, 2, 5 and 6 contribute to the accumulation of PRDM4 in the nucleus. Their effect is additive as deleting either ZF1-2 or ZF 5–6 redistributes PRDM4 protein from being almost exclusively nuclear to cytosolic and nuclear. We investigated the potential mechanism of nuclear shuttling of PRDM4 via the importin α/β-mediated pathway and find that PRDM4 nuclear targeting is independent of α/β-mediated nuclear import. -- Highlights: •Zinc fingers 1, 2, 5, and 6 are necessary for efficient nuclear localisation of PRDM4. •Zinc fingers 3 and 4 are dispensable for nuclear localisation of PRDM4. •Zinc knuckle is dispensable for nuclear localisation of PRDM4. •PRDM4 nuclear transport is independent of importin α/β-mediated pathway of nuclear import.« less

  8. 30 CFR 77.1430 - Wire ropes; scope.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Wire ropes; scope. 77.1430 Section 77.1430... Hoisting Wire Ropes § 77.1430 Wire ropes; scope. (a) Sections 77.1431 through 77.1438 apply to wire ropes.... (b) These standards do not apply to wire ropes used for elevators. ...

  9. 49 CFR 234.231 - Fouling wires.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Fouling wires. 234.231 Section 234.231..., Inspection, and Testing Maintenance Standards § 234.231 Fouling wires. Each set of fouling wires in a highway... single duplex wire with single plug acting as fouling wires is prohibited. Existing installations having...

  10. 30 CFR 77.1430 - Wire ropes; scope.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Wire ropes; scope. 77.1430 Section 77.1430... Hoisting Wire Ropes § 77.1430 Wire ropes; scope. (a) Sections 77.1431 through 77.1438 apply to wire ropes.... (b) These standards do not apply to wire ropes used for elevators. ...

  11. 49 CFR 234.231 - Fouling wires.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Fouling wires. 234.231 Section 234.231..., Inspection, and Testing Maintenance Standards § 234.231 Fouling wires. Each set of fouling wires in a highway... single duplex wire with single plug acting as fouling wires is prohibited. Existing installations having...

  12. 75 FR 32747 - Prestressed Concrete Steel Wire Strand from Mexico: Rescission of Antidumping Duty Administrative...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-09

    ... Wire Strand from Mexico: Rescission of Antidumping Duty Administrative Review AGENCY: Import... request an administrative review of the antidumping duty order on prestressed concrete steel wire strand... received a timely request from American Spring Wire Corp., Insteel Wire Products Co., and Sumiden Wire...

  13. 29 CFR 1926.1413 - Wire rope-inspection.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    .... Apparent deficiencies in this category are: (A) Visible broken wires, as follows: (1) In running wire ropes: Six randomly distributed broken wires in one rope lay or three broken wires in one strand in one rope... around the rope. (2) In rotation resistant ropes: Two randomly distributed broken wires in six rope...

  14. 29 CFR 1926.1413 - Wire rope-inspection.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    .... Apparent deficiencies in this category are: (A) Visible broken wires, as follows: (1) In running wire ropes: Six randomly distributed broken wires in one rope lay or three broken wires in one strand in one rope... around the rope. (2) In rotation resistant ropes: Two randomly distributed broken wires in six rope...

  15. 29 CFR 1926.1413 - Wire rope-inspection.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    .... Apparent deficiencies in this category are: (A) Visible broken wires, as follows: (1) In running wire ropes: Six randomly distributed broken wires in one rope lay or three broken wires in one strand in one rope... around the rope. (2) In rotation resistant ropes: Two randomly distributed broken wires in six rope...

  16. International space station wire program

    NASA Technical Reports Server (NTRS)

    May, Todd

    1995-01-01

    Hardware provider wire systems and current wire insulation issues for the International Space Station (ISS) program are discussed in this viewgraph presentation. Wire insulation issues include silicone wire contamination, Tefzel cold temperature flexibility, and Russian polyimide wire insulation. ISS is a complex program with hardware developed and managed by many countries and hundreds of contractors. Most of the obvious wire insulation issues are known by contractors and have been precluded by proper selection.

  17. U.S. Navy Wire-Rope Handbook. Volume 2. Wire-Rope Analysis and Design Data

    DTIC Science & Technology

    1976-01-01

    beneficial from the standpoint of wire - bending stress. How- ever, there is a design trade-off here in that the smaller L/d becomes, the lower are the...wires of a rope, it is first necessary to determine the radii of curvature of the wires prior to and after bending the rope. The wire - bending stress can... wire bending stress. 4.3. CONTACT STRESSES Contact stresses in a wire rope are one of the most important determinants of its fatigue life and are, by far

  18. Model-Based Testability Assessment and Directed Troubleshooting of Shuttle Wiring Systems

    NASA Technical Reports Server (NTRS)

    Deb, Somnath; Domagala, Chuck; Shrestha, Roshan; Malepati, Venkatesh; Cavanaugh, Kevin; Patterson-Hine, Ann; Sanderfer, Dwight; Cockrell, Jim; Norvig, Peter (Technical Monitor)

    2000-01-01

    We have recently completed a pilot study on the Space shuttle wiring system commissioned by the Wiring Integrity Research (WIRe) team at NASA Ames Research Center, As the space shuttle ages, it is experiencing wiring degradation problems including arcing, chaffing insulation breakdown and broken conductors. A systematic and comprehensive test process is required to thoroughly test and quality assure (QA) the wiring systems. The NASA WIRe team recognized the value of a formal model based analysis for risk-assessment and fault coverage analysis. However. wiring systems are complex and involve over 50,000 wire segments. Therefore, NASA commissioned this pilot study with Qualtech Systems. Inc. (QSI) to explore means of automatically extracting high fidelity multi-signal models from wiring information database for use with QSI's Testability Engineering and Maintenance System (TEAMS) tool.

  19. Long-term decision regret after post-prostatectomy image-guided intensity-modulated radiotherapy.

    PubMed

    Shakespeare, Thomas P; Chin, Stephen; Manuel, Lucy; Wen, Shelly; Hoffman, Matthew; Wilcox, Shea W; Aherne, Noel J

    2017-02-01

    Decision regret (DR) may occur when a patient believes their outcome would have been better if they had decided differently about their management. Although some studies investigate DR after treatment for localised prostate cancer, none report DR in patients undergoing surgery and post-prostatectomy radiotherapy. We evaluated DR in this group of patients overall, and for specific components of therapy. We surveyed 83 patients, with minimum 5 years follow-up, treated with radical prostatectomy (RP) and post-prostatectomy image-guided intensity-modulated radiotherapy (IG-IMRT) to 64-66 Gy following www.EviQ.org.au protocols. A validated questionnaire identified DR if men either indicated that they would have been better off had they chosen another treatment, or they wished they could change their mind about treatment. There was an 85.5% response rate, with median follow-up post-IMRT 78 months. Adjuvant IG-IMRT was used in 28% of patients, salvage in 72% and ADT in 48%. A total of 70% of patients remained disease-free. Overall, 16.9% of patients expressed DR for treatment, with fourfold more regret for the RP component of treatment compared to radiotherapy (16.9% vs 4.2%, P = 0.01). DR for androgen deprivation was 14.3%. Patients were regretful of surgery due to toxicity, not being adequately informed about radiotherapy as an alternative, positive margins and surgery costs (83%, 33%, 25% and 8% of regretful patients respectively). Toxicity caused DR in the three radiotherapy-regretful and four ADT-regretful patients. Patients were twice as regretful overall, and of surgery, for salvage vs adjuvant approaches (both 19.6% vs 10.0%). Decision regret after RP and post-prostatectomy IG-IMRT is uncommon, although patients regret RP more than post-operative IG-IMRT. This should reassure urologists referring patients for post-prostatectomy IG-IMRT, particularly in the immediate adjuvant setting. Other implications include appropriate patient selection for RP (and obtaining clear margins), and ensuring adequately discussing definitive radiotherapy as an alternative to surgery. © 2016 The Royal Australian and New Zealand College of Radiologists.

  20. Outcomes of Heimlich valve drainage in dogs.

    PubMed

    Salci, H; Bayram, A S; Gorgul, O S

    2009-04-01

    Retrospective study of the outcomes of Heimlich valve drainage in dogs. Medical records of the past 3 years were retrospectively reviewed. Heimlich valve drainage was used in 34 dogs (median body weight 30 +/- 5 kg): lobectomy (n = 15), pneumonectomy (n = 9), intrathoracic oesophageal surgery (n = 2), diaphragmatic hernia repair (n = 1), traumatic open pneumothorax (n = 2), bilobectomy (n = 2), ligation of the thoracic duct (n = 1), and chylothorax and pneumothorax (n = 1 each). Evacuation of air and/or fluid from the pleural cavity was performed with the Heimlich valve following thoracostomy tube insertion. During drainage, the dogs were closely monitored for possible respiratory failure. Termination of Heimlich valve drainage was controlled with underwater seal drainage and assessed with thoracic radiography. Negative intrathoracic pressure was provided in 29 dogs without any complications. Post pneumonectomy respiratory syncope and post lobectomy massive hemothorax, which did not originate from the Heimlich valve, were the only postoperative complications. Dysfunction of the valve diaphragm, open pneumothorax and intrathoracic localisation of an acute gastric dilatation-volvulus syndrome caused by a left-sided diaphragmatic hernia following pneumonectomy were the Heimlich valve drainage complications. The Heimlich valve can be used as a continuous drainage device in dogs, but the complications reported here should be considered by veterinary practitioners.

  1. Evolution of the Mount Woods Inlier, northern Gawler Craton, Southern Australia: an integrated structural and aeromagnetic analysis

    NASA Astrophysics Data System (ADS)

    Betts, Peter G.; Valenta, Rick K.; Finlay, Jim

    2003-05-01

    Structural mapping integrated with interpretation and forward modelling of aeromagnetic data form complimentary and powerful tools for regional structural analysis because both techniques focus on architecture and overprinting relationships. This approach is used to constrain the geometry and evolution of the sparsely exposed Mount Woods Inlier in the northern Gawler Craton. The Mount Woods Inlier records a history of poly-phase deformation, high-temperature metamorphism, and syn- and post-orogenic magmatism between ca. 1736 and 1584 Ma. The earliest deformation involved isoclinal folding, and the development of bedding parallel and axial planar gneissic foliation (S 1). This was accompanied by high-temperature, upper amphibolite to granulite facies metamorphism at ca. 1736 Ma. During subsequent north-south shortening (D 2), open to isoclinal south-southeast-oriented F 2 folds developed as the Palaeoproterozoic successions of the inlier were thrust over the Archaean nuclei of the Gawler Craton. The syn-D 2 Engenina Adamellite was emplaced at ca. 1692 Ma. The post-D 2 history involved shear zone development and localised folding, exhumation of metamorphic rocks, and deposition of clastic sediments prior to the emplacement of the ca. 1584 Ma Granite Balta Suite. The Mount Woods Inlier is interpreted as the northern continuation of the Kimban Orogen.

  2. Forming Refractory Insulation On Copper Wire

    NASA Technical Reports Server (NTRS)

    Setlock, J.; Roberts, G.

    1995-01-01

    Alternative insulating process forms flexible coat of uncured refractory insulating material on copper wire. Coated wire formed into coil or other complex shape. Wire-coating apparatus forms "green" coat on copper wire. After wire coiled, heating converts "green" coat to refractory electrical insulator. When cured to final brittle form, insulating material withstands temperatures above melting temperature of wire. Process used to make coils for motors, solenoids, and other electrical devices to be operated at high temperatures.

  3. 30 CFR 75.906 - Trailing cables for mobile equipment, ground wires, and ground check wires.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Trailing cables for mobile equipment, ground wires, and ground check wires. 75.906 Section 75.906 Mineral Resources MINE SAFETY AND HEALTH..., ground wires, and ground check wires. [Statutory Provisions] Trailing cables for mobile equipment shall...

  4. 75 FR 36678 - Prestressed Concrete Steel Wire Strand From China; Determinations

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-28

    ... Concrete Steel Wire Strand From China; Determinations On the basis of the record \\1\\ developed in the... prestressed concrete steel wire strand (PC strand), provided for in subheading 7312.10.30 of the Harmonized... Spring Wire Corp. (Bedford Heights, OH); Insteel Wire Products Co. (Mt. Airy, NC); and Sumiden Wire...

  5. 49 CFR 236.108 - Insulation resistance tests, wires in trunking and cables.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Insulation resistance tests, wires in trunking and... Insulation resistance tests, wires in trunking and cables. (a) Insulation resistance of wires and cables, except wires connected directly to track rails, shall be tested when wires, cables, and insulation are...

  6. 76 FR 23548 - Galvanized Steel Wire From the People's Republic of China and Mexico: Initiation of Antidumping...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-27

    ... Wire From the People's Republic of China and Mexico: Initiation of Antidumping Duty Investigations...'') received petitions concerning imports of galvanized steel wire from the PRC and Mexico filed in proper form on behalf of Davis Wire Corporation (``Davis Wire''), Johnstown Wire Technologies, Inc., Mid-South...

  7. 49 CFR 236.108 - Insulation resistance tests, wires in trunking and cables.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Insulation resistance tests, wires in trunking and... Insulation resistance tests, wires in trunking and cables. (a) Insulation resistance of wires and cables, except wires connected directly to track rails, shall be tested when wires, cables, and insulation are...

  8. 30 CFR 75.906 - Trailing cables for mobile equipment, ground wires, and ground check wires.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Trailing cables for mobile equipment, ground wires, and ground check wires. 75.906 Section 75.906 Mineral Resources MINE SAFETY AND HEALTH..., ground wires, and ground check wires. [Statutory Provisions] Trailing cables for mobile equipment shall...

  9. 49 CFR 234.239 - Tagging of wires and interference of wires or tags with signal apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... with signal apparatus. 234.239 Section 234.239 Transportation Other Regulations Relating to... Tagging of wires and interference of wires or tags with signal apparatus. Each wire shall be tagged or... of the apparatus. This requirement applies to each wire at each terminal in all housings including...

  10. 49 CFR 234.239 - Tagging of wires and interference of wires or tags with signal apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... with signal apparatus. 234.239 Section 234.239 Transportation Other Regulations Relating to... Tagging of wires and interference of wires or tags with signal apparatus. Each wire shall be tagged or... of the apparatus. This requirement applies to each wire at each terminal in all housings including...

  11. Plasma arc torch with coaxial wire feed

    DOEpatents

    Hooper, Frederick M

    2002-01-01

    A plasma arc welding apparatus having a coaxial wire feed. The apparatus includes a plasma arc welding torch, a wire guide disposed coaxially inside of the plasma arc welding torch, and a hollow non-consumable electrode. The coaxial wire guide feeds non-electrified filler wire through the tip of the hollow non-consumable electrode during plasma arc welding. Non-electrified filler wires as small as 0.010 inches can be used. This invention allows precision control of the positioning and feeding of the filler wire during plasma arc welding. Since the non-electrified filler wire is fed coaxially through the center of the plasma arc torch's electrode and nozzle, the wire is automatically aimed at the optimum point in the weld zone. Therefore, there is no need for additional equipment to position and feed the filler wire from the side before or during welding.

  12. Wire ablation dynamics model and its application to imploding wire arrays of different geometries.

    PubMed

    Esaulov, A A; Kantsyrev, V L; Safronova, A S; Velikovich, A L; Shrestha, I K; Williamson, K M; Osborne, G C

    2012-10-01

    The paper presents an extended description of the amplified wire ablation dynamics model (WADM), which accounts in a single simulation for the processes of wire ablation and implosion of a wire array load of arbitrary geometry and wire material composition. To investigate the role of wire ablation effects, the implosions of cylindrical and planar wire array loads at the university based generators Cobra (Cornell University) and Zebra (University of Nevada, Reno) have been analyzed. The analysis of the experimental data shows that the wire mass ablation rate can be described as a function of the current through the wire and some coefficient defined by the wire material properties. The aluminum wires were found to ablate with the highest rate, while the copper ablation is the slowest one. The lower wire ablation rate results in a higher inward velocity of the ablated plasma, a higher rate of the energy coupling with the ablated plasma, and a more significant delay of implosion for a heavy load due to the ablation effects, which manifest the most in a cylindrical array configuration and almost vanish in a single-planar array configuration. The WADM is an efficient tool suited for wire array load design and optimization in wide parameter ranges, including the loads with specific properties needed for the inertial confinement fusion research and laboratory astrophysics experiments. The data output from the WADM simulation can be used to simplify the radiation magnetohydrodynamics modeling of the wire array plasma.

  13. Fixation Release and the Bone Bandaid: A New Bone Fixation Device Paradigm

    PubMed Central

    Shayesteh Moghaddam, Narges; Jahadakbar, Ahmadreza; Amerinatanzi, Amirhesam; Skoracki, Roman; Miller, Michael; Dean, David; Elahinia, Mohammad

    2017-01-01

    The current gold standard of care for mandibular segmental defeat reconstruction is the use of Ti-6Al-4V immobilization hardware and fibular double barrel graft. This method is often successful immediately at restoring mandible function, however the highly stiff fixation hardware causes stress shielding of the grafted bone and stress concentration in the fixation device over time which can lead to fixation device failure and revision surgery. The purpose of reconstructive surgery could be to create normal stress trajectories in the mandible following engraftment. We investigate the use of a two stage mechanism which separates the immobilization/healing and regenerative phases of mandibular segmental defect treatment. The device includes the use of a very stiff, Ti-6Al-4V, releasable mechanism which assures bone healing. Therefore it could be released once the reconstructed boney tissue and any of its ligamentous attachments have completely healed. Underneath the released Ti-6Al-4V plate would be a pre-loaded nitinol (NiTi) wire-frame apparatus that facilitates the normal stress-strain trajectory through the engrafted bone after the graft is healed in place and the Ti-6Al-4V fixation device has been released. Due to the use of NiTi wires forming a netting that connects vascularized bone and possibly bone chips, bone grafts are also more likely to be incorporate rather than to resorb. We first evaluated a healthy adult mandible during normal mastication to obtain the normal stress-strain distribution. Then, we developed the finite element (FE) model of the mandibular reconstruction (in the M1-3 region) with the proposed fixation device during the healing (locked state) and post-healing (released state) periods. To recreate normal stress trajectory in the reconstructed mandible, we applied the Response Surface Methodology (RMS) to optimize the Bone Bandaid geometry (i.e., wire diameters and location). The results demonstrate that the proposed mechanism immobilizes the grafted bone in the locked state properly since the maximum resultant gap (21.54 micron) between the graft and host mandible surfaces are in the safe region (less than 300 micron). By considering the von Mises criteria for failure, FE analysis together with experimental studies (i.e., compressive and tensile testing on the inferior and superior fixation devices, respectively) confirm that the proposed fixation devices do not fail, showing safety factor of at least 10.3. Based on the Response Surface Methodology (RSM) technique, the optimal parameter values for the wires are achieved (0.65 mm and 1 mm for the superior and inferior wires, respectively) and the required level of preload on each wire are calculated (369.8 N and 229 N for the inferior and superior wires, respectively). The FE results for stress distribution on the reconstructed mandible during the released state closely match that of a healthy mandible. PMID:28952484

  14. Method of fabricating a homogeneous wire of inter-metallic alloy

    DOEpatents

    Ohriner, Evan Keith; Blue, Craig Alan

    2001-01-01

    A method for fabricating a homogeneous wire of inter-metallic alloy comprising the steps of providing a base-metal wire bundle comprising a metal, an alloy or a combination thereof; working the wire bundle through at least one die to obtain a desired dimension and to form a precursor wire; and, controllably heating the precursor wire such that a portion of the wire will become liquid while simultaneously maintaining its desired shape, whereby substantial homogenization of the wire occurs in the liquid state and additional homogenization occurs in the solid state resulting in a homogenous alloy product.

  15. Enhancement of bending strain tolerance and current carrying property of MgB2 based multifilamentary wires

    NASA Astrophysics Data System (ADS)

    Thomas, Syju; Varghese, Neson; Rahul, S.; Devadas, K. M.; Vinod, K.; Syamaprasad, U.

    2012-12-01

    The effect of bending strain on current carrying capacity of MgB2 multifilamentary wires was studied with 4, 8 and 16 multifilamentary wires. The critical current density (JC) of straight wires and bent wires with 5, 10, and 15 cm diameter was measured. Both annealed & bent and bent & annealed wires were used for measurement. The JC of annealed & bent wires were found to decrease with decrease in bent diameter and the rate of degradation of JC decreased with increasing number of filaments, while bent & annealed wires almost retained its JC at all diameters studied.

  16. Precision wire feeder for small diameter wire

    DOEpatents

    Brandon, Eldon D.; Hooper, Frederick M.; Reichenbach, Marvin L.

    1992-01-01

    A device for feeding small diameter wire having a diameter less than 0.04 mm (16 mil) to a welding station includes a driving wheel for controllably applying a non-deforming driving force to the wire to move the free end of the wire towards the welding station; and a tension device such as a torque motor for constantly applying a reverse force to the wire in opposition to the driving force to keep the wire taut.

  17. Precision wire feeder for small diameter wire

    DOEpatents

    Brandon, E.D.; Hooper, F.M.; Reichenbach, M.L.

    1992-08-11

    A device for feeding small diameter wire having a diameter less than 0.04 mm (16 mil) to a welding station includes a driving wheel for controllably applying a non-deforming driving force to the wire to move the free end of the wire towards the welding station; and a tension device such as a torque motor for constantly applying a reverse force to the wire in opposition to the driving force to keep the wire taut. 1 figure.

  18. Apollo experience report: Electrical wiring subsystem

    NASA Technical Reports Server (NTRS)

    White, L. D.

    1975-01-01

    The general requirements of the electrical wiring subsystems and the problem areas and solutions that occurred during the major part of the Apollo Program are detailed in this report. The concepts and definitions of specific requirements for electrical wiring; wire-connecting devices; and wire-harness fabrication, checkout, and installation techniques are discussed. The design and development of electrical wiring and wire-connecting devices are described. Mission performance is discussed, and conclusions and recommendations for future programs are presented.

  19. Development of termination and utilization concepts for flat conductor cables. Volume 2: Utilization of small gage wire round conductor cables

    NASA Technical Reports Server (NTRS)

    1972-01-01

    The practical use of small-gage round wire for electrical wiring in manned air and space vehicle environments is discussed. The investigation consisted on a study of wire construction and candidate wire harness concepts, fabrication of small-gage wire harnesses, and verification of promising configurations by laboratory evaluation. The wire constructions selected for harness fabrication are described. Results of the laboratory evaluation are included.

  20. Electrode carrying wire for GTAW welding

    NASA Technical Reports Server (NTRS)

    Morgan, Gene E. (Inventor); Dyer, Gerald E. (Inventor)

    1990-01-01

    A welding torch for gas tungsten arc welding apparatus has a hollow tungsten electrode including a ceramic liner and forms the filler metal wire guide. The wire is fed through the tungsten electrode thereby reducing the size of the torch to eliminate clearance problems which exist with external wire guides. Since the wire is preheated from the tungsten more wire may be fed into the weld puddle, and the wire will not oxidize because it is always within the shielding gas.

  1. Internal wire guide for GTAW welding

    NASA Technical Reports Server (NTRS)

    Morgan, Gene E. (Inventor); Dyer, Gerald E. (Inventor)

    1989-01-01

    A welding torch for gas tungsten arc welding apparatus has a filler metal wire guide positioned within the torch, and within the shielding gas nozzle. The wire guide is adjacent to the tungsten electrode and has a ceramic liner through which the wire is fed. This reduces the size of the torch and eliminates the outside clearance problems that exit with external wire guides. Additionally, since the wire is always within the shielding gas, oxidizing of the wire is eliminated.

  2. Linear and nonlinear evolution of azimuthal clumping instabilities in a Z-pinch wire array

    DOE PAGES

    Tang, Wilkin; Strickler, T. S.; Lau, Y. Y.; ...

    2007-01-31

    This study presents an analytic theory on the linear and nonlinear evolution of the most unstable azimuthal clumping mode, known as the pi-mode, in a discrete wire array. In the pi-mode, neighboring wires of the array pair-up as a result of the mutual attraction of the wires which carry current in the same direction. The analytic solution displays two regimes, where the collective interactions of all wires dominate, versus where the interaction of the neighboring, single wire dominates. This solution was corroborated by two vastly different numerical codes which were used to simulate arrays with both high wire numbers (upmore » to 600) and low wire number (8). All solutions show that azimuthal clumping of discrete wires occurs before appreciable radial motion of the wires. Thus, absence of azimuthal clumping of wires in comparison with the wires’ radial motion may imply substantial lack of wire currents. Finally, while the present theory and simulations have ignored the plasma corona and axial variations, it is argued that their effects, and the complete account of the three-dimensional feature of the pi-mode, together with a scaling study of the wire number, may be expediently simulated by using only one single wire in an annular wedge with a reflection condition imposed on the wedge’s boundary.« less

  3. 47 CFR 76.804 - Disposition of home run wiring.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 4 2014-10-01 2014-10-01 false Disposition of home run wiring. 76.804 Section... MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Cable Inside Wiring § 76.804 Disposition of home run wiring. (a) Building-by-building disposition of home run wiring. (1) Where an MVPD owns the home run wiring in an MDU...

  4. 47 CFR 76.804 - Disposition of home run wiring.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 4 2011-10-01 2011-10-01 false Disposition of home run wiring. 76.804 Section... MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Cable Inside Wiring § 76.804 Disposition of home run wiring. (a) Building-by-building disposition of home run wiring. (1) Where an MVPD owns the home run wiring in an MDU...

  5. 47 CFR 76.804 - Disposition of home run wiring.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 4 2012-10-01 2012-10-01 false Disposition of home run wiring. 76.804 Section... MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Cable Inside Wiring § 76.804 Disposition of home run wiring. (a) Building-by-building disposition of home run wiring. (1) Where an MVPD owns the home run wiring in an MDU...

  6. 47 CFR 76.804 - Disposition of home run wiring.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 4 2013-10-01 2013-10-01 false Disposition of home run wiring. 76.804 Section... MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Cable Inside Wiring § 76.804 Disposition of home run wiring. (a) Building-by-building disposition of home run wiring. (1) Where an MVPD owns the home run wiring in an MDU...

  7. 75 FR 60480 - In the Matter of Certain Bulk Welding Wire Containers and Components Thereof and Welding Wire...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-30

    ... Welding Wire Containers and Components Thereof and Welding Wire; Notice of Commission Determination To... within the United States after importation of certain bulk welding wire containers, components thereof, and welding wire by reason of infringement of certain claims of United States Patent Nos. 6,260,781; 6...

  8. 76 FR 68422 - Galvanized Steel Wire From Mexico: Preliminary Determination of Sales at Less Than Fair Value and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-04

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-201-840] Galvanized Steel Wire From... determines that galvanized steel wire (galvanized wire) from Mexico is being, or is likely to be, sold in the... investigation on galvanized wire from Mexico. See Galvanized Steel Wire from the People's Republic of China and...

  9. 47 CFR 36.341 - Cable and wire facilities expenses-Account 6410 (Class B telephone companies); Accounts 6411...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 2 2010-10-01 2010-10-01 false Cable and wire facilities expenses-Account 6410... Operating Expenses and Taxes Cable and Wire Facilities Expenses § 36.341 Cable and wire facilities expenses... network cable, aerial wire, and conduit systems. (b) The general method of separating cable and wire...

  10. 76 FR 78882 - Carbon and Certain Alloy Steel Wire Rod From Mexico: Affirmative Preliminary Determination of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-20

    ... Steel Wire Rod From Mexico: Affirmative Preliminary Determination of Circumvention of the Antidumping.... SUMMARY: We preliminarily determine that carbon and certain alloy steel wire rod (wire rod) with an actual.... de C.V. (Deacero) is circumventing the antidumping duty order on wire rod from Mexico (Wire Rod Order...

  11. 47 CFR 36.341 - Cable and wire facilities expenses-Account 6410 (Class B telephone companies); Accounts 6411...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 2 2011-10-01 2011-10-01 false Cable and wire facilities expenses-Account 6410... Operating Expenses and Taxes Cable and Wire Facilities Expenses § 36.341 Cable and wire facilities expenses... network cable, aerial wire, and conduit systems. (b) The general method of separating cable and wire...

  12. 76 FR 52899 - Airworthiness Directives; The Boeing Company Model 767-200, -300, and -300F Series Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-24

    ... the compliance times specified, unless already done. Installation of New Relay and Wiring Bundle (g... certain wiring changes, installing a new relay and necessary wiring in the cabin air conditioning and... for changing the wire bundle route and wiring, installing a new relay and applicable wiring in the...

  13. Localisation in a Growth Model with Interaction

    NASA Astrophysics Data System (ADS)

    Costa, M.; Menshikov, M.; Shcherbakov, V.; Vachkovskaia, M.

    2018-05-01

    This paper concerns the long term behaviour of a growth model describing a random sequential allocation of particles on a finite cycle graph. The model can be regarded as a reinforced urn model with graph-based interaction. It is motivated by cooperative sequential adsorption, where adsorption rates at a site depend on the configuration of existing particles in the neighbourhood of that site. Our main result is that, with probability one, the growth process will eventually localise either at a single site, or at a pair of neighbouring sites.

  14. Maladie de Castleman: localisation inhabituelle du thorax

    PubMed Central

    Eloueriachi, Fayçal; Caidi, Mohammed; Zouaidia, Fouad; Ouchen, Fahd; Maidi, Mehdi; Fennane, Hicham; Bouchikh, Mohamed; Achir, Abdellah; Benosman, Abdellatif

    2012-01-01

    La maladie de Castleman est une affection rare qui peut toucher le thorax. La localisation diaphragmatique est exceptionnelle. Nous rapportons le cas d'une patiente de 47 ans, chez qui une thoracotomie exploratrice a permis l'exérèse d'une masse du sinus médiastinal antérieur droit, en continuité avec le diaphragme et dont l'histologie est en faveur de la maladie de Castleman de type hyalino-vasculaire. Les particularités cliniques, radiologiques et évolutives ont été revues. PMID:23133711

  15. Long Range Navigation for Mars Rovers Using Sensor-Based Path Planning and Visual Localisation

    NASA Technical Reports Server (NTRS)

    Laubach, Sharon L.; Olson, Clark F.; Burdick, Joel W.; Hayati, Samad

    1999-01-01

    The Mars Pathfinder mission illustrated the benefits of including a mobile robotic explorer on a planetary mission. However, for future Mars rover missions, significantly increased autonomy in navigation is required in order to meet demanding mission criteria. To address these requirements, we have developed new path planning and localisation capabilities that allow a rover to navigate robustly to a distant landmark. These algorithms have been implemented on the JPL Rocky 7 prototype microrover and have been tested extensively in the JPL MarsYard, as well as in natural terrain.

  16. Localisation in a Growth Model with Interaction

    NASA Astrophysics Data System (ADS)

    Costa, M.; Menshikov, M.; Shcherbakov, V.; Vachkovskaia, M.

    2018-06-01

    This paper concerns the long term behaviour of a growth model describing a random sequential allocation of particles on a finite cycle graph. The model can be regarded as a reinforced urn model with graph-based interaction. It is motivated by cooperative sequential adsorption, where adsorption rates at a site depend on the configuration of existing particles in the neighbourhood of that site. Our main result is that, with probability one, the growth process will eventually localise either at a single site, or at a pair of neighbouring sites.

  17. Evaluating the Surface Characteristics of Stainless Steel, TMA, Timolium, and Titanium-niobium Wires: An in vivo Scanning Electron Microscope Study.

    PubMed

    Babu, K Pradeep; Keerthi, V Naga; Madathody, Deepika; Prasanna, A Laxmi; Gopinath, Vidhya; Kumar, M Senthil; Kumar, A Nanda

    2016-05-01

    Recent metallurgical research and advancement in material science has benefited orthodontists in the selection of an appropriate wire size and alloy type, which is necessary to provide an optimum and predictable treatment results. The purpose of the study was to clinically evaluate and compare the surface characteristics of 16 x 22 stainless steel, Titanium molybdenum alloy, timolium, and titanium-niobium before and after placing them in a patient's mouth for 3 months using a scanning electron microscope (SEM). The total sample size was 40, which were divided into four groups (group 1 - stainless steel wires, 10 samples, group 2 - TMA wires, 10 samples, group 3 - timolium wires, 10 samples, and group 4 - titanium-niobium wires, 10 samples), and these were further subdivided into 5 each. The first subgroup of five samples was placed in the patient's mouth and was evaluated under SEM, and another subgroup of five samples was directly subjected to the SEM. Scanning electron microscopic evaluation of surface characteristics of unused 16 x 22 rectangular stainless steel wire under 500 x magnification showed an overall smooth surface. Stainless steel wire samples placed in the patient's mouth showed black hazy patches, which may be interoperated as areas of stress. TMA unused wires showed multiple small voids of areas and small craters with fewer elevated regions. The TMA wire samples placed in the patient's mouth showed black hazy patches and prominent ridges, making the wire rougher. Timolium unused archwires showed heavy roughness and voids, whereas wires tested in the patient's mouth showed homogeneous distribution of deep cracks and craters. Unused titanium-niobium archwires showed uniform prominent striations and ridges with occasional voids, whereas wires used in the patient's mouth showed prominent huge voids that could be interpreted as maximum stress areas. Stainless steel (group 1) used and unused wires showed smooth surface characteristics when compared with all the other three groups followed by timolium, which was superior to titanium-niobium wires and TMA wires. Timolium wires are superior to titanium-niobium wires and TMA wires.

  18. Material and biofilm load of K wires in toe surgery: titanium versus stainless steel.

    PubMed

    Clauss, Martin; Graf, Susanne; Gersbach, Silke; Hintermann, Beat; Ilchmann, Thomas; Knupp, Markus

    2013-07-01

    Recurrence rates for toe deformity correction are high and primarily are attributable to scar contractures. These contractures may result from subclinical infection. We hypothesized that (1) recurrence of toe deformities and residual pain are related to low-grade infections from biofilm formation on percutaneous K wires, (2) biofilm formation is lower on titanium (Ti) K wires compared with stainless steel (SS) K wires, and (3) clinical outcome is superior with the use of Ti K wires compared with SS K wires. In this prospective nonrandomized, comparative study, we investigated 135 lesser toe deformities (61 patients; 49 women; mean ± SD age, 60 ± 15 years) temporarily fixed with K wires between August 2010 and March 2011 (81 SS, 54 Ti). K wires were removed after 6 weeks. The presence of biofilm-related infections was analyzed by sonication. High bacterial loads (> 500 colony-forming units [CFU]/mL) were detected on all six toes requiring revision before 6 months. Increased bacterial load was associated with pain and swelling but not recurrence of the deformity. More SS K wires had greater than 100 CFU/mL bacteria than Ti K wires. For K wires with a bacterial count greater than 100 CFU/mL, toes with Ti K wires had a lower recurrence rate, less pain, and less swelling than toes with SS K wires. Ti K wires showed superior clinical outcomes to SS K wires. This appears to be attributable to reduced infection rates. Although additional study is needed, we currently recommend the use of Ti K wires for the transfixation of toe deformities. Level II, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.

  19. Using wire shaping techniques and holographic optics to optimize deposition characteristics in wire-based laser cladding.

    PubMed

    Goffin, N J; Higginson, R L; Tyrer, J R

    2016-12-01

    In laser cladding, the potential benefits of wire feeding are considerable. Typical problems with the use of powder, such as gas entrapment, sub-100% material density and low deposition rate are all avoided with the use of wire. However, the use of a powder-based source material is the industry standard, with wire-based deposition generally regarded as an academic curiosity. This is because, although wire-based methods have been shown to be capable of superior quality results, the wire-based process is more difficult to control. In this work, the potential for wire shaping techniques, combined with existing holographic optical element knowledge, is investigated in order to further improve the processing characteristics. Experiments with pre-placed wire showed the ability of shaped wire to provide uniformity of wire melting compared with standard round wire, giving reduced power density requirements and superior control of clad track dilution. When feeding with flat wire, the resulting clad tracks showed a greater level of quality consistency and became less sensitive to alterations in processing conditions. In addition, a 22% increase in deposition rate was achieved. Stacking of multiple layers demonstrated the ability to create fully dense, three-dimensional structures, with directional metallurgical grain growth and uniform chemical structure.

  20. Using wire shaping techniques and holographic optics to optimize deposition characteristics in wire-based laser cladding

    PubMed Central

    Higginson, R. L.; Tyrer, J. R.

    2016-01-01

    In laser cladding, the potential benefits of wire feeding are considerable. Typical problems with the use of powder, such as gas entrapment, sub-100% material density and low deposition rate are all avoided with the use of wire. However, the use of a powder-based source material is the industry standard, with wire-based deposition generally regarded as an academic curiosity. This is because, although wire-based methods have been shown to be capable of superior quality results, the wire-based process is more difficult to control. In this work, the potential for wire shaping techniques, combined with existing holographic optical element knowledge, is investigated in order to further improve the processing characteristics. Experiments with pre-placed wire showed the ability of shaped wire to provide uniformity of wire melting compared with standard round wire, giving reduced power density requirements and superior control of clad track dilution. When feeding with flat wire, the resulting clad tracks showed a greater level of quality consistency and became less sensitive to alterations in processing conditions. In addition, a 22% increase in deposition rate was achieved. Stacking of multiple layers demonstrated the ability to create fully dense, three-dimensional structures, with directional metallurgical grain growth and uniform chemical structure. PMID:28119550

Top