29 CFR 1915.112 - Ropes, chains and slings.
Code of Federal Regulations, 2011 CFR
2011-07-01
... plow steel wire rope and wire rope slings with various types of terminals. For sizes, classifications... than five (5) is maintained. (b) Wire rope and wire rope slings. (1) Tables G-2 through G-5 in § 1915... blunted. (3) Where U-bolt wire rope clips are used to form eyes, Table G-6 in § 1915.118 shall be used to...
29 CFR 1915.112 - Ropes, chains and slings.
Code of Federal Regulations, 2010 CFR
2010-07-01
... plow steel wire rope and wire rope slings with various types of terminals. For sizes, classifications... than five (5) is maintained. (b) Wire rope and wire rope slings. (1) Tables G-2 through G-5 in § 1915... blunted. (3) Where U-bolt wire rope clips are used to form eyes, Table G-6 in § 1915.118 shall be used to...
29 CFR 1919.71 - Unit proof test and examination of cranes.
Code of Federal Regulations, 2014 CFR
2014-07-01
..., including wire rope and wire rope terminals and connections, shall be checked with particular attention to sections of wire rope exposed to abnormal wear and to sections not normally exposed for examination. The provisions of § 1919.24 shall apply in wire rope examinations. Cracked or deformed hooks shall be discarded...
29 CFR 1919.71 - Unit proof test and examination of cranes.
Code of Federal Regulations, 2012 CFR
2012-07-01
..., including wire rope and wire rope terminals and connections, shall be checked with particular attention to sections of wire rope exposed to abnormal wear and to sections not normally exposed for examination. The provisions of § 1919.24 shall apply in wire rope examinations. Cracked or deformed hooks shall be discarded...
29 CFR 1919.71 - Unit proof test and examination of cranes.
Code of Federal Regulations, 2013 CFR
2013-07-01
..., including wire rope and wire rope terminals and connections, shall be checked with particular attention to sections of wire rope exposed to abnormal wear and to sections not normally exposed for examination. The provisions of § 1919.24 shall apply in wire rope examinations. Cracked or deformed hooks shall be discarded...
Study on nondestructive detection system based on x-ray for wire ropes conveyer belt
NASA Astrophysics Data System (ADS)
Miao, Changyun; Shi, Boya; Wan, Peng; Li, Jie
2008-03-01
A nondestructive detection system based on X-ray for wire ropes conveyer belt is designed by X-ray detection technology. In this paper X-ray detection principle is analyzed, a design scheme of the system is presented; image processing of conveyer belt is researched and image processing algorithms are given; X-ray acquisition receiving board is designed with the use of FPGA and DSP; the software of the system is programmed by C#.NET on WINXP/WIN2000 platform. The experiment indicates the system can implement remote real-time detection of wire ropes conveyer belt images, find faults and give an alarm in time. The system is direct perceived, strong real-time and high accurate. It can be used for fault detection of wire ropes conveyer belts in mines, ports, terminals and other fields.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Improved Plow Steel, Independent Wire Rope Core, Wire Rope and Wire Rope Slings [In tons of 2,000 pounds... for Improved Plow Steel, Independent Wire Rope Core, Wire Rope Slings [in tons of 2,000 pounds] Two...-4—Rated Capacities for Improved Plow Steel, Fiber Core, Wire Rope and Wire Rope Slings [in tons of 2...
Code of Federal Regulations, 2011 CFR
2011-07-01
... Improved Plow Steel, Independent Wire Rope Core, Wire Rope and Wire Rope Slings [In tons of 2,000 pounds... for Improved Plow Steel, Independent Wire Rope Core, Wire Rope Slings [in tons of 2,000 pounds] Two...-4—Rated Capacities for Improved Plow Steel, Fiber Core, Wire Rope and Wire Rope Slings [in tons of 2...
29 CFR 1926.1413 - Wire rope-inspection.
Code of Federal Regulations, 2012 CFR
2012-07-01
.... Apparent deficiencies in this category are: (A) Visible broken wires, as follows: (1) In running wire ropes: Six randomly distributed broken wires in one rope lay or three broken wires in one strand in one rope... around the rope. (2) In rotation resistant ropes: Two randomly distributed broken wires in six rope...
29 CFR 1926.1413 - Wire rope-inspection.
Code of Federal Regulations, 2013 CFR
2013-07-01
.... Apparent deficiencies in this category are: (A) Visible broken wires, as follows: (1) In running wire ropes: Six randomly distributed broken wires in one rope lay or three broken wires in one strand in one rope... around the rope. (2) In rotation resistant ropes: Two randomly distributed broken wires in six rope...
29 CFR 1926.1413 - Wire rope-inspection.
Code of Federal Regulations, 2014 CFR
2014-07-01
.... Apparent deficiencies in this category are: (A) Visible broken wires, as follows: (1) In running wire ropes: Six randomly distributed broken wires in one rope lay or three broken wires in one strand in one rope... around the rope. (2) In rotation resistant ropes: Two randomly distributed broken wires in six rope...
30 CFR 77.1430 - Wire ropes; scope.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Wire ropes; scope. 77.1430 Section 77.1430... Hoisting Wire Ropes § 77.1430 Wire ropes; scope. (a) Sections 77.1431 through 77.1438 apply to wire ropes.... (b) These standards do not apply to wire ropes used for elevators. ...
30 CFR 77.1430 - Wire ropes; scope.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Wire ropes; scope. 77.1430 Section 77.1430... Hoisting Wire Ropes § 77.1430 Wire ropes; scope. (a) Sections 77.1431 through 77.1438 apply to wire ropes.... (b) These standards do not apply to wire ropes used for elevators. ...
29 CFR 1917.42 - Miscellaneous auxiliary gear.
Code of Federal Regulations, 2011 CFR
2011-07-01
... and Spacing of U-Bolt Wire Rope Clips Improved plow steel, rope diameter (inches/(cm)) Minimum number.... (b) Wire rope and wire rope slings. (1) The employer shall ascertain and adhere to the manufacturer's recommended ratings for wire rope and wire rope slings and shall have such ratings available for inspection...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 29 Labor 7 2011-07-01 2011-07-01 false Wire rope. 1919.79 Section 1919.79 Labor Regulations...) GEAR CERTIFICATION Certification of Shore-Based Material Handling Devices § 1919.79 Wire rope. (a) Wire rope and replacement wire rope shall be of the same size, same or better grade, and same construction...
Code of Federal Regulations, 2010 CFR
2010-07-01
... 29 Labor 7 2010-07-01 2010-07-01 false Wire rope. 1919.79 Section 1919.79 Labor Regulations...) GEAR CERTIFICATION Certification of Shore-Based Material Handling Devices § 1919.79 Wire rope. (a) Wire rope and replacement wire rope shall be of the same size, same or better grade, and same construction...
30 CFR 75.1430 - Wire ropes; scope.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Wire ropes; scope. 75.1430 Section 75.1430... MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Hoisting and Mantrips Wire Ropes § 75.1430 Wire ropes; scope. (a) Sections 75.1430 through 75.1438 apply to wire ropes in service used to hoist— (1) Persons in...
30 CFR 75.1430 - Wire ropes; scope.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Wire ropes; scope. 75.1430 Section 75.1430... MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Hoisting and Mantrips Wire Ropes § 75.1430 Wire ropes; scope. (a) Sections 75.1430 through 75.1438 apply to wire ropes in service used to hoist— (1) Persons in...
29 CFR 1919.24 - Limitations on use of wire rope.
Code of Federal Regulations, 2012 CFR
2012-07-01
... number of visible broken wires exceeds 10 percent of the total number of wires, or if the rope shows... 29 Labor 7 2012-07-01 2012-07-01 false Limitations on use of wire rope. 1919.24 Section 1919.24... on use of wire rope. (a) An eye splice made in any wire rope shall have at least three tucks with a...
29 CFR 1919.24 - Limitations on use of wire rope.
Code of Federal Regulations, 2013 CFR
2013-07-01
... number of visible broken wires exceeds 10 percent of the total number of wires, or if the rope shows... 29 Labor 7 2013-07-01 2013-07-01 false Limitations on use of wire rope. 1919.24 Section 1919.24... on use of wire rope. (a) An eye splice made in any wire rope shall have at least three tucks with a...
29 CFR 1919.24 - Limitations on use of wire rope.
Code of Federal Regulations, 2014 CFR
2014-07-01
... number of visible broken wires exceeds 10 percent of the total number of wires, or if the rope shows... 29 Labor 7 2014-07-01 2014-07-01 false Limitations on use of wire rope. 1919.24 Section 1919.24... on use of wire rope. (a) An eye splice made in any wire rope shall have at least three tucks with a...
U.S. Navy Wire-Rope Handbook. Volume 2. Wire-Rope Analysis and Design Data
1976-01-01
beneficial from the standpoint of wire - bending stress. How- ever, there is a design trade-off here in that the smaller L/d becomes, the lower are the...wires of a rope, it is first necessary to determine the radii of curvature of the wires prior to and after bending the rope. The wire - bending stress can... wire bending stress. 4.3. CONTACT STRESSES Contact stresses in a wire rope are one of the most important determinants of its fatigue life and are, by far
29 CFR 1919.24 - Limitations on use of wire rope.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 29 Labor 7 2011-07-01 2011-07-01 false Limitations on use of wire rope. 1919.24 Section 1919.24... on use of wire rope. (a) An eye splice made in any wire rope shall have at least three tucks with a... in the ends of wire rope cargo falls shall not be formed by knots and, in single part falls, shall...
29 CFR 1919.24 - Limitations on use of wire rope.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 29 Labor 7 2010-07-01 2010-07-01 false Limitations on use of wire rope. 1919.24 Section 1919.24... on use of wire rope. (a) An eye splice made in any wire rope shall have at least three tucks with a... in the ends of wire rope cargo falls shall not be formed by knots and, in single part falls, shall...
29 CFR 1926.1414 - Wire rope-selection and installation criteria.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 29 Labor 8 2011-07-01 2011-07-01 false Wire rope-selection and installation criteria. 1926.1414... Derricks in Construction § 1926.1414 Wire rope—selection and installation criteria. (a) Original equipment wire rope and replacement wire rope must be selected and installed in accordance with the requirements...
30 CFR 57.19024 - Retirement criteria.
Code of Federal Regulations, 2011 CFR
2011-07-01
... broken wires within a rope lay length, excluding filler wires, exceeds either— (1) Five percent of the... regular lay rope, more than one broken wire in the valley between strands in one rope lay length. (c) A... Wire Ropes § 57.19024 Retirement criteria. Unless damage or deterioration is removed by cutoff, wire...
30 CFR 57.19024 - Retirement criteria.
Code of Federal Regulations, 2012 CFR
2012-07-01
... broken wires within a rope lay length, excluding filler wires, exceeds either— (1) Five percent of the... regular lay rope, more than one broken wire in the valley between strands in one rope lay length. (c) A... Wire Ropes § 57.19024 Retirement criteria. Unless damage or deterioration is removed by cutoff, wire...
30 CFR 57.19024 - Retirement criteria.
Code of Federal Regulations, 2014 CFR
2014-07-01
... broken wires within a rope lay length, excluding filler wires, exceeds either— (1) Five percent of the... regular lay rope, more than one broken wire in the valley between strands in one rope lay length. (c) A... Wire Ropes § 57.19024 Retirement criteria. Unless damage or deterioration is removed by cutoff, wire...
30 CFR 57.19024 - Retirement criteria.
Code of Federal Regulations, 2013 CFR
2013-07-01
... broken wires within a rope lay length, excluding filler wires, exceeds either— (1) Five percent of the... regular lay rope, more than one broken wire in the valley between strands in one rope lay length. (c) A... Wire Ropes § 57.19024 Retirement criteria. Unless damage or deterioration is removed by cutoff, wire...
Pull-pull position control of dual motor wire rope transmission.
Guo, Quan; Jiao, Zongxia; Yan, Liang; Yu, Qian; Shang, Yaoxing
2016-08-01
Wire rope transmission is very efficient because of the small total moving object mass. The wire rope could only transmit pulling force. Therefore it has to be kept in a tightened state during transmission; in high speed applications the dynamic performance depends on the rope's stiffness, which can be adjusted by the wire rope tension. To improve the system dynamic performance output, this paper proposes a novel pull-pull method based on dual motors connected by wire ropes, for precise, high speed position control applications. The method can regulate target position and wire rope tension simultaneously. Wire ropes remain in a pre-tightening state at all times, which prevents the influence of elasticity and reduces the position tracking error in the changing direction process. Simulations and experiments were conducted; the results indicate that both position precision and superior dynamic performance can be synchronously achieved. The research is relevant to space craft precision pointing instruments.
30 CFR 77.1434 - Retirement criteria.
Code of Federal Regulations, 2014 CFR
2014-07-01
... broken wires within a rope lay length, excluding filler wires, exceeds either— (1) Five percent of the... regular lay rope, more than one broken wire in the valley between strands in one rope lay length; (c) A... Hoisting Wire Ropes § 77.1434 Retirement criteria. Unless damage or deterioration is removed by cutoff...
30 CFR 77.1434 - Retirement criteria.
Code of Federal Regulations, 2012 CFR
2012-07-01
... broken wires within a rope lay length, excluding filler wires, exceeds either— (1) Five percent of the... regular lay rope, more than one broken wire in the valley between strands in one rope lay length; (c) A... Hoisting Wire Ropes § 77.1434 Retirement criteria. Unless damage or deterioration is removed by cutoff...
30 CFR 77.1434 - Retirement criteria.
Code of Federal Regulations, 2011 CFR
2011-07-01
... broken wires within a rope lay length, excluding filler wires, exceeds either— (1) Five percent of the... regular lay rope, more than one broken wire in the valley between strands in one rope lay length; (c) A... Hoisting Wire Ropes § 77.1434 Retirement criteria. Unless damage or deterioration is removed by cutoff...
30 CFR 77.1434 - Retirement criteria.
Code of Federal Regulations, 2013 CFR
2013-07-01
... broken wires within a rope lay length, excluding filler wires, exceeds either— (1) Five percent of the... regular lay rope, more than one broken wire in the valley between strands in one rope lay length; (c) A... Hoisting Wire Ropes § 77.1434 Retirement criteria. Unless damage or deterioration is removed by cutoff...
Influences on lifetime of wire ropes in traction lifts
NASA Astrophysics Data System (ADS)
Vogel, W.
2016-05-01
Traction lifts are complex systems with rotating and translating moving masses, springs and dampers and several system inputs from the lifts and the users. The wire ropes are essential mechanical elements. The mechanical properties of the ropes in use depend on the rope construction, the load situation, nonlinearities and the lift dimensions. The mechanical properties are important for the proper use in lifts and the ride quality. But first of all the wire ropes (for all other suspension means as well) have to satisfy the safety relevant requirements sufficient lifetime, reliable determination of discard and sufficient and limited traction capacity. The lifetime of the wire ropes better the number of trips until rope discard depends on a lot of parameters of the rope and the rope application eg use of plastic deflection sheaves and reverse bending layouts. New challenges for rope lifetime are resulting from the more or less open D/d-ratio limits possible by certificates concerning the examination of conformity by notified bodies. This paper will highlight the basics of wire rope technology, the endurance and lifetime of wire ropes running over sheaves, and the different influences from the ropes and more and more important from the lift application parameters. Very often underestimated are the influences of transport, storage, installation and maintenance. With this background we will lead over to the calculation methods of wire rope lifetime considering the actual findings of wire rope endurance research. We'll show in this paper new and innovative facts as the influence of rope length and size factor in the lifetime formular, the reduction of lifetime caused by traction grooves, the new model for the calculation in reverse bending operations and the statistically firmed possibilities for machine roomless lifts (MRL) under very small bending conditions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... alloy steel chain, wire rope, metal mesh, natural or synthetic fiber rope (conventional three strand... steel chain sling or wire rope sling. (See Fig. N-184-3.) Mechanical coupling link is a nonwelded... Slings 6×19 and 6×37 Classification Improved Plow Steel Grade Rope With Independent Wire Rope Core (IWRC...
Code of Federal Regulations, 2011 CFR
2011-07-01
... alloy steel chain, wire rope, metal mesh, natural or synthetic fiber rope (conventional three strand... steel chain sling or wire rope sling. (See Fig. N-184-3.) Mechanical coupling link is a nonwelded... Slings 6×19 and 6×37 Classification Improved Plow Steel Grade Rope With Independent Wire Rope Core (IWRC...
29 CFR 1919.33 - Proof tests-wire rope.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 29 Labor 7 2010-07-01 2010-07-01 false Proof tests-wire rope. 1919.33 Section 1919.33 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR... Persons § 1919.33 Proof tests—wire rope. Wire rope, except as provided in § 1919.14(b), shall be tested by...
46 CFR 108.705 - Anchors, chains, wire rope, and hawsers.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Anchors, chains, wire rope, and hawsers. 108.705 Section... UNITS DESIGN AND EQUIPMENT Miscellaneous Equipment § 108.705 Anchors, chains, wire rope, and hawsers. (a) Each unit must be fitted with anchors, chains, wire rope, and hawsers in agreement with the standards...
46 CFR 108.705 - Anchors, chains, wire rope, and hawsers.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Anchors, chains, wire rope, and hawsers. 108.705 Section... UNITS DESIGN AND EQUIPMENT Miscellaneous Equipment § 108.705 Anchors, chains, wire rope, and hawsers. (a) Each unit must be fitted with anchors, chains, wire rope, and hawsers in agreement with the standards...
29 CFR 1919.33 - Proof tests-wire rope.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 29 Labor 7 2011-07-01 2011-07-01 false Proof tests-wire rope. 1919.33 Section 1919.33 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR... Persons § 1919.33 Proof tests—wire rope. Wire rope, except as provided in § 1919.14(b), shall be tested by...
46 CFR 108.497 - Fireman's outfits.
Code of Federal Regulations, 2010 CFR
2010-10-01
... belt or a suitable harness; (2) Is made of bronze wire rope, inherently corrosion resistant steel wire rope, or galvanized or tinned steel wire rope; (3) Is made up of enough 15.2 meters (50 foot) or greater lengths of wire rope to permit use of the outfit in any location on the unit; (4) Has each end...
46 CFR 108.497 - Fireman's outfits.
Code of Federal Regulations, 2011 CFR
2011-10-01
... belt or a suitable harness; (2) Is made of bronze wire rope, inherently corrosion resistant steel wire rope, or galvanized or tinned steel wire rope; (3) Is made up of enough 15.2 meters (50 foot) or greater lengths of wire rope to permit use of the outfit in any location on the unit; (4) Has each end...
33 CFR 165.803 - Mississippi River-regulated navigation area.
Code of Federal Regulations, 2013 CFR
2013-07-01
... breaking strength of three parts of 7/8 inch diameter wire rope; or (3) Fixed rigging that is at least... end of the tier is secured to at least one mooring device. (3) Each wire rope used between the... inch diameter wire rope. (4) Each wire rope used between the downstream end of a barge and a mooring...
33 CFR 165.803 - Mississippi River-regulated navigation area.
Code of Federal Regulations, 2012 CFR
2012-07-01
... breaking strength of three parts of 7/8 inch diameter wire rope; or (3) Fixed rigging that is at least... end of the tier is secured to at least one mooring device. (3) Each wire rope used between the... inch diameter wire rope. (4) Each wire rope used between the downstream end of a barge and a mooring...
33 CFR 165.803 - Mississippi River-regulated navigation area.
Code of Federal Regulations, 2011 CFR
2011-07-01
... breaking strength of three parts of 7/8 inch diameter wire rope; or (3) Fixed rigging that is at least... end of the tier is secured to at least one mooring device. (3) Each wire rope used between the... inch diameter wire rope. (4) Each wire rope used between the downstream end of a barge and a mooring...
33 CFR 165.803 - Mississippi River-regulated navigation area.
Code of Federal Regulations, 2014 CFR
2014-07-01
... breaking strength of three parts of 7/8 inch diameter wire rope; or (3) Fixed rigging that is at least... end of the tier is secured to at least one mooring device. (3) Each wire rope used between the... inch diameter wire rope. (4) Each wire rope used between the downstream end of a barge and a mooring...
46 CFR 108.497 - Fireman's outfits.
Code of Federal Regulations, 2013 CFR
2013-10-01
... belt or a suitable harness; (2) Is made of bronze wire rope, inherently corrosion resistant steel wire rope, or galvanized or tinned steel wire rope; (3) Is made up of enough 15.2 meters (50 foot) or greater lengths of wire rope to permit use of the outfit in any location on the unit; (4) Has each end...
46 CFR 108.497 - Fireman's outfits.
Code of Federal Regulations, 2014 CFR
2014-10-01
... belt or a suitable harness; (2) Is made of bronze wire rope, inherently corrosion resistant steel wire rope, or galvanized or tinned steel wire rope; (3) Is made up of enough 15.2 meters (50 foot) or greater lengths of wire rope to permit use of the outfit in any location on the unit; (4) Has each end...
46 CFR 108.497 - Fireman's outfits.
Code of Federal Regulations, 2012 CFR
2012-10-01
... belt or a suitable harness; (2) Is made of bronze wire rope, inherently corrosion resistant steel wire rope, or galvanized or tinned steel wire rope; (3) Is made up of enough 15.2 meters (50 foot) or greater lengths of wire rope to permit use of the outfit in any location on the unit; (4) Has each end...
29 CFR 1919.33 - Proof tests-wire rope.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 29 Labor 7 2013-07-01 2013-07-01 false Proof tests-wire rope. 1919.33 Section 1919.33 Labor... Persons § 1919.33 Proof tests—wire rope. Wire rope, except as provided in § 1919.14(b), shall be tested by... acceptable to the Administration on the basis of design, shall not exceed one-fifth of the breaking load of...
29 CFR 1919.33 - Proof tests-wire rope.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 29 Labor 7 2012-07-01 2012-07-01 false Proof tests-wire rope. 1919.33 Section 1919.33 Labor... Persons § 1919.33 Proof tests—wire rope. Wire rope, except as provided in § 1919.14(b), shall be tested by... acceptable to the Administration on the basis of design, shall not exceed one-fifth of the breaking load of...
29 CFR 1919.33 - Proof tests-wire rope.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 29 Labor 7 2014-07-01 2014-07-01 false Proof tests-wire rope. 1919.33 Section 1919.33 Labor... Persons § 1919.33 Proof tests—wire rope. Wire rope, except as provided in § 1919.14(b), shall be tested by... acceptable to the Administration on the basis of design, shall not exceed one-fifth of the breaking load of...
30 CFR 77.1433 - Examinations.
Code of Federal Regulations, 2014 CFR
2014-07-01
..., and improper lubrication or dressing. In addition, visual examination for wear and broken wires shall... Wire Ropes § 77.1433 Examinations. (a) At least once every fourteen calendar days, each wire rope in... examined on a daily basis. (b) Before any person is hoisted with a newly installed wire rope or any wire...
30 CFR 77.1433 - Examinations.
Code of Federal Regulations, 2013 CFR
2013-07-01
..., and improper lubrication or dressing. In addition, visual examination for wear and broken wires shall... Wire Ropes § 77.1433 Examinations. (a) At least once every fourteen calendar days, each wire rope in... examined on a daily basis. (b) Before any person is hoisted with a newly installed wire rope or any wire...
30 CFR 77.1433 - Examinations.
Code of Federal Regulations, 2012 CFR
2012-07-01
..., and improper lubrication or dressing. In addition, visual examination for wear and broken wires shall... Wire Ropes § 77.1433 Examinations. (a) At least once every fourteen calendar days, each wire rope in... examined on a daily basis. (b) Before any person is hoisted with a newly installed wire rope or any wire...
30 CFR 56.19024 - Retirement criteria.
Code of Federal Regulations, 2012 CFR
2012-07-01
... lay rope, more than one broken wire in the valley between strands in one rope lay length. (c) A loss... SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Personnel Hoisting Wire Ropes § 56.19024 Retirement criteria. Unless damage or deterioration is removed by cutoff, wire ropes...
30 CFR 56.19024 - Retirement criteria.
Code of Federal Regulations, 2011 CFR
2011-07-01
... lay rope, more than one broken wire in the valley between strands in one rope lay length. (c) A loss... SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Personnel Hoisting Wire Ropes § 56.19024 Retirement criteria. Unless damage or deterioration is removed by cutoff, wire ropes...
30 CFR 56.19024 - Retirement criteria.
Code of Federal Regulations, 2014 CFR
2014-07-01
... lay rope, more than one broken wire in the valley between strands in one rope lay length. (c) A loss... SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Personnel Hoisting Wire Ropes § 56.19024 Retirement criteria. Unless damage or deterioration is removed by cutoff, wire ropes...
30 CFR 56.19024 - Retirement criteria.
Code of Federal Regulations, 2013 CFR
2013-07-01
... lay rope, more than one broken wire in the valley between strands in one rope lay length. (c) A loss... SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Personnel Hoisting Wire Ropes § 56.19024 Retirement criteria. Unless damage or deterioration is removed by cutoff, wire ropes...
30 CFR 77.1437 - End attachment retermination.
Code of Federal Regulations, 2013 CFR
2013-07-01
... MINES Personnel Hoisting Wire Ropes § 77.1437 End attachment retermination. Damaged or deteriorated wire rope shall be removed by cutoff and the rope reterminated where there is— (a) More than one broken wire...
30 CFR 77.1437 - End attachment retermination.
Code of Federal Regulations, 2014 CFR
2014-07-01
... MINES Personnel Hoisting Wire Ropes § 77.1437 End attachment retermination. Damaged or deteriorated wire rope shall be removed by cutoff and the rope reterminated where there is— (a) More than one broken wire...
30 CFR 77.1437 - End attachment retermination.
Code of Federal Regulations, 2012 CFR
2012-07-01
... MINES Personnel Hoisting Wire Ropes § 77.1437 End attachment retermination. Damaged or deteriorated wire rope shall be removed by cutoff and the rope reterminated where there is— (a) More than one broken wire...
30 CFR 77.1437 - End attachment retermination.
Code of Federal Regulations, 2011 CFR
2011-07-01
... MINES Personnel Hoisting Wire Ropes § 77.1437 End attachment retermination. Damaged or deteriorated wire rope shall be removed by cutoff and the rope reterminated where there is— (a) More than one broken wire...
30 CFR 56.19024 - Retirement criteria.
Code of Federal Regulations, 2010 CFR
2010-07-01
... wires within a rope lay length, excluding filler wires, exceeds either— (1) Five percent of the total... lay rope, more than one broken wire in the valley between strands in one rope lay length. (c) A loss...
30 CFR 57.19024 - Retirement criteria.
Code of Federal Regulations, 2010 CFR
2010-07-01
... broken wires within a rope lay length, excluding filler wires, exceeds either— (1) Five percent of the... regular lay rope, more than one broken wire in the valley between strands in one rope lay length. (c) A...
30 CFR 57.19027 - End attachment retermination.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Hoisting Wire Ropes § 57.19027 End attachment retermination. Damaged or deteriorated wire rope shall be removed by cutoff and the rope reterminated where there is— (a) More than one broken wire at an attachment...
30 CFR 57.19027 - End attachment retermination.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Hoisting Wire Ropes § 57.19027 End attachment retermination. Damaged or deteriorated wire rope shall be removed by cutoff and the rope reterminated where there is— (a) More than one broken wire at an attachment...
30 CFR 57.19027 - End attachment retermination.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Hoisting Wire Ropes § 57.19027 End attachment retermination. Damaged or deteriorated wire rope shall be removed by cutoff and the rope reterminated where there is— (a) More than one broken wire at an attachment...
30 CFR 56.19027 - End attachment retermination.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Hoisting Wire Ropes § 56.19027 End attachment retermination. Damaged or deteriorated wire rope shall be removed by cutoff and the rope reterminated where there is— (a) More than one broken wire at an attachment...
30 CFR 56.19027 - End attachment retermination.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Hoisting Wire Ropes § 56.19027 End attachment retermination. Damaged or deteriorated wire rope shall be removed by cutoff and the rope reterminated where there is— (a) More than one broken wire at an attachment...
30 CFR 57.19027 - End attachment retermination.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Hoisting Wire Ropes § 57.19027 End attachment retermination. Damaged or deteriorated wire rope shall be removed by cutoff and the rope reterminated where there is— (a) More than one broken wire at an attachment...
30 CFR 56.19027 - End attachment retermination.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Hoisting Wire Ropes § 56.19027 End attachment retermination. Damaged or deteriorated wire rope shall be removed by cutoff and the rope reterminated where there is— (a) More than one broken wire at an attachment...
30 CFR 56.19027 - End attachment retermination.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Hoisting Wire Ropes § 56.19027 End attachment retermination. Damaged or deteriorated wire rope shall be removed by cutoff and the rope reterminated where there is— (a) More than one broken wire at an attachment...
30 CFR 57.19027 - End attachment retermination.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Hoisting Wire Ropes § 57.19027 End attachment retermination. Damaged or deteriorated wire rope shall be removed by cutoff and the rope reterminated where there is— (a) More than one broken wire at an attachment...
30 CFR 56.19027 - End attachment retermination.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Hoisting Wire Ropes § 56.19027 End attachment retermination. Damaged or deteriorated wire rope shall be removed by cutoff and the rope reterminated where there is— (a) More than one broken wire at an attachment...
29 CFR 1926.1413 - Wire rope-inspection.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 29 Labor 8 2011-07-01 2011-07-01 false Wire rope-inspection. 1926.1413 Section 1926.1413 Labor... Wire rope—inspection. (a) Shift inspection. (1) A competent person must begin a visual inspection prior... inspection must consist of observation of wire ropes (running and standing) that are likely to be in use...
30 CFR 75.1437 - End attachment retermination.
Code of Federal Regulations, 2014 CFR
2014-07-01
... AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Hoisting and Mantrips Wire Ropes § 75.1437 End attachment retermination. Damaged or deteriorated wire rope shall be removed by cutoff and the rope reterminated where there is— (a) More than one broken wire at an attachment; (b) Improper...
30 CFR 75.1437 - End attachment retermination.
Code of Federal Regulations, 2010 CFR
2010-07-01
... AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Hoisting and Mantrips Wire Ropes § 75.1437 End attachment retermination. Damaged or deteriorated wire rope shall be removed by cutoff and the rope reterminated where there is— (a) More than one broken wire at an attachment; (b) Improper...
30 CFR 75.1437 - End attachment retermination.
Code of Federal Regulations, 2012 CFR
2012-07-01
... AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Hoisting and Mantrips Wire Ropes § 75.1437 End attachment retermination. Damaged or deteriorated wire rope shall be removed by cutoff and the rope reterminated where there is— (a) More than one broken wire at an attachment; (b) Improper...
30 CFR 75.1437 - End attachment retermination.
Code of Federal Regulations, 2011 CFR
2011-07-01
... AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Hoisting and Mantrips Wire Ropes § 75.1437 End attachment retermination. Damaged or deteriorated wire rope shall be removed by cutoff and the rope reterminated where there is— (a) More than one broken wire at an attachment; (b) Improper...
30 CFR 75.1437 - End attachment retermination.
Code of Federal Regulations, 2013 CFR
2013-07-01
... AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Hoisting and Mantrips Wire Ropes § 75.1437 End attachment retermination. Damaged or deteriorated wire rope shall be removed by cutoff and the rope reterminated where there is— (a) More than one broken wire at an attachment; (b) Improper...
30 CFR 75.1434 - Retirement criteria.
Code of Federal Regulations, 2014 CFR
2014-07-01
... when any of the following conditions occurs: (a) The number of broken wires within a rope lay length... percent of the total number of wires within any strand; (b) On a regular lay rope, more than one broken... MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Hoisting and Mantrips Wire Ropes § 75.1434 Retirement...
30 CFR 75.1434 - Retirement criteria.
Code of Federal Regulations, 2013 CFR
2013-07-01
... when any of the following conditions occurs: (a) The number of broken wires within a rope lay length... percent of the total number of wires within any strand; (b) On a regular lay rope, more than one broken... MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Hoisting and Mantrips Wire Ropes § 75.1434 Retirement...
30 CFR 75.1434 - Retirement criteria.
Code of Federal Regulations, 2011 CFR
2011-07-01
... when any of the following conditions occurs: (a) The number of broken wires within a rope lay length... percent of the total number of wires within any strand; (b) On a regular lay rope, more than one broken... MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Hoisting and Mantrips Wire Ropes § 75.1434 Retirement...
30 CFR 75.1434 - Retirement criteria.
Code of Federal Regulations, 2012 CFR
2012-07-01
... when any of the following conditions occurs: (a) The number of broken wires within a rope lay length... percent of the total number of wires within any strand; (b) On a regular lay rope, more than one broken... MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Hoisting and Mantrips Wire Ropes § 75.1434 Retirement...
Advanced signal processing methods applied to guided waves for wire rope defect detection
NASA Astrophysics Data System (ADS)
Tse, Peter W.; Rostami, Javad
2016-02-01
Steel wire ropes, which are usually composed of a polymer core and enclosed by twisted wires, are used to hoist heavy loads. These loads are different structures that can be clamshells, draglines, elevators, etc. Since the loading of these structures is dynamic, the ropes are working under fluctuating forces in a corrosive environment. This consequently leads to progressive loss of the metallic cross-section due to abrasion and corrosion. These defects can be seen in the forms of roughened and pitted surface of the ropes, reduction in diameter, and broken wires. Therefore, their deterioration must be monitored so that any unexpected damage or corrosion can be detected before it causes fatal accident. This is of vital importance in the case of passenger transportation, particularly in elevators in which any failure may cause a catastrophic disaster. At present, the widely used methods for thorough inspection of wire ropes include visual inspection and magnetic flux leakage (MFL). Reliability of the first method is questionable since it only depends on the operators' eyes that fails to determine the integrity of internal wires. The later method has the drawback of being a point by point and time-consuming inspection method. Ultrasonic guided wave (UGW) based inspection, which has proved its capability in inspecting plate like structures such as tubes and pipes, can monitor the cross-section of wire ropes in their entire length from a single point. However, UGW have drawn less attention for defect detection in wire ropes. This paper reports the condition monitoring of a steel wire rope from a hoisting elevator with broken wires as a result of corrosive environment and fatigue. Experiments were conducted to investigate the efficiency of using magnetostrictive based UGW for rope defect detection. The obtained signals were analyzed by two time-frequency representation (TFR) methods, namely the Short Time Fourier Transform (STFT) and the Wavelet analysis. The location of the defect and its severity were successfully identified and characterized.
A NASA/Industry/University Partnership for Development of Dual-Use Vibration Isolation Technology
NASA Technical Reports Server (NTRS)
Tinker, Michael L.
1994-01-01
A partnership is described that was formed as a result of a NASA university grant for the study of wire rope vibration isolation systems. Vibration isolators of this type are currently used in the Space Shuttle Orbiter and engine test facility, and have potential application in the international space station and other space vehicles. Wire rope isolators were considered for use on the Hubble Space Telescope and the military has used wire rope technology extensively. The desire of the wire rope industry to expand sales in commercial markets coupled with results of the prior NASA funded study, led to the formation of a partnership including NASA, the university involved in the research grant, and a small company that designs wire rope systems. Goals include the development of improved mathematical models and a designers handbook to facilitate the use of the new modeling tools.
Researching on Control Device of Prestressing Wire Reinforcement
NASA Astrophysics Data System (ADS)
Si, Jianhui; Guo, Yangbo; Liu, Maoshe
2017-06-01
This paper mainly introduces a device for controlling prestress and its related research methods, the advantage of this method is that the reinforcement process is easy to operate and control the prestress of wire rope accurately. The relationship between the stress and strain of the steel wire rope is monitored during the experiment, and the one - to - one relationship between the controllable position and the pretightening force of the steel wire rope is confirmed by the 5mm steel wire rope, and the results are analyzed theoretically by the measured elastic modulus. The results show that the method can effectively control the prestressing force, and the result provides a reference method for strengthening the concrete column with prestressed steel strand.
Initial investigations into the damping characteristics of wire rope vibration isolators
NASA Technical Reports Server (NTRS)
Cutchins, M. A.; Cochran, J. E., Jr.; Kumar, K.; Fitz-Coy, N. G.; Tinker, M. L.
1987-01-01
Passive dampers composed of coils of multi-strand wire rope are investigated. Analytical results range from those produced by complex NASTRAN models to those of a Coulomb damping model with variable friction force. The latter agrees well with experiment. The Coulomb model is also utilized to generate hysteresis loops. Various other models related to early experimental investigations are described. Significant closed-form static solutions for physical properties of single-and multi-strand wire ropes are developed for certain specific geometries and loading conditions. NASTRAN models concentrate on model generation and mode shapes of 2-strand and 7-strand straight wire ropes with interfacial forces.
Zhu, Zhen-Cai; Li, Xiang; Shen, Gang; Zhu, Wei-Dong
2018-01-01
This paper concerns wire rope tension control of a double-rope winding hoisting system (DRWHS), which consists of a hoisting system employed to realize a transportation function and an electro-hydraulic servo system utilized to adjust wire rope tensions. A dynamic model of the DRWHS is developed in which parameter uncertainties and external disturbances are considered. A comparison between simulation results using the dynamic model and experimental results using a double-rope winding hoisting experimental system is given in order to demonstrate accuracy of the dynamic model. In order to improve the wire rope tension coordination control performance of the DRWHS, a robust nonlinear adaptive backstepping controller (RNABC) combined with a nonlinear disturbance observer (NDO) is proposed. Main features of the proposed combined controller are: (1) using the RNABC to adjust wire rope tensions with consideration of parameter uncertainties, whose parameters are designed online by adaptive laws derived from Lyapunov stability theory to guarantee the control performance and stability of the closed-loop system; and (2) introducing the NDO to deal with uncertain external disturbances. In order to demonstrate feasibility and effectiveness of the proposed controller, experimental studies have been conducted on the DRWHS controlled by an xPC rapid prototyping system. Experimental results verify that the proposed controller exhibits excellent performance on wire rope tension coordination control compared with a conventional proportional-integral (PI) controller and adaptive backstepping controller. Copyright © 2017 ISA. All rights reserved.
U.S. Navy Wire-Rope Handbook. Volume 1. Design and Engineering of Wire-Rope Systems
1976-01-01
by " braiding " or "weaving" one rope end into another. Splices may be made at the end of a single rope after forming a loop (an eye splice) or between...rags, large pieces of old hemp rope and fire hose are other popular types of chafing gear for semi-fixed position ropes (see Figure 7-3(b)). 7.4. LINKS...Figure 7-3. Chafing Gear 7-6 Links 7.4. SWOOD PLANK FIRE HOSE ., ’ _APPLY GREASE CANJVAS, LEATHER, COPPER (b) For Semi-Fixed Position Ropes lo- Figcre
NASA Astrophysics Data System (ADS)
Walsh, M.
1984-05-01
This research demonstrated the feasibility of supplying approximately 1 watt of electrical power for one year on the sea bed with a novel battery, the rope battery. The proposed battery would look very much like a small diameter wire rope, possibly hundreds of feet long. This unusual shape permits the rope battery to take full advantage of the vastness of the ocean floor and permits at great pressure the steady diffusion of reaction products away from the battery itself. A sea water battery is described consisting of an inner bundle of coated wires which slowly corrode and an outer layer of fine wires which simultaneously provides strength, armor and surface area for slow hydrogen evolution. Two variations are examined. The fuse utilizes magnesium wires and burns slowly from the end. The rope utilizes lithium-zinc alloys and is slowly consumed along its entire length.
A study on MFL based wire rope damage detection
NASA Astrophysics Data System (ADS)
Park, J.; Kim, J.-W.; Kim, J.; Park, S.
2017-04-01
Non-destructive testing on wire rope is in great demand to prevent safety accidents at sites where many heavy equipment using ropes are installed. In this paper, a research on quantification of magnetic flux leakage (MFL) signals were carried out to detect damages on wire rope. First, a simulation study was performed with a steel rod model using a finite element analysis (FEA) program. The leakage signals from the simulation study were obtained and it was compared for parameter: depth of defect. Then, an experiment on same conditions was conducted to verify the results of the simulation. Throughout the results, the MFL signal was quantified and a wire rope damage detection was then confirmed to be feasible. In further study, it is expected that the damage characterization of an entire specimen will be visualized as well.
Code of Federal Regulations, 2010 CFR
2010-10-01
... that for polypropylene fiber rope. (d) Welded steel chain which is not marked or labeled to enable... for grade 30 proof coil chain. (e)(1) Wire rope which is not marked by the manufacturer with a working... listed in the Wire Rope Users Manual. (2) Wire which is not marked or labeled to enable identification of...
Code of Federal Regulations, 2011 CFR
2011-10-01
... that for polypropylene fiber rope. (d) Welded steel chain which is not marked or labeled to enable... for grade 30 proof coil chain. (e)(1) Wire rope which is not marked by the manufacturer with a working... listed in the Wire Rope Users Manual. (2) Wire which is not marked or labeled to enable identification of...
An evaluation of Brifen wire rope safety fence.
DOT National Transportation Integrated Search
2013-01-01
Three : - : strand : cable barriers were first developed in the 1960s and found to have several desirable : characteristics as compared to other roadside barriers such as guard rail : . : Brifen Wire Rope Safety Fence is : a four strand woven wire...
1983-05-01
SMP has sinkers attached to wire rope within the water column. This location of sinkers was not duplicated on the TCP moor because of possible wear and...breaking (new chain) 1-3/4" wire rope breaking strength is approx. 224. kips; F.S. = 6.4 against breaking (new rope) Buoy, dia=9.5’,h=5’ buoy freeboard is...6.4 against breakingconnecting agis 1-3/4" wire rope with J b- chain tails 13 See Appendix B for details of the mooring buoy design and Appendix C
30 CFR 57.19023 - Examinations.
Code of Federal Regulations, 2011 CFR
2011-07-01
... improper lubrication or dressing. In addition, visual examination for wear and broken wires shall be made... HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Personnel Hoisting Wire Ropes § 57.19023 Examinations. (a) At least once every fourteen calendar days, each wire rope in service...
30 CFR 57.19023 - Examinations.
Code of Federal Regulations, 2013 CFR
2013-07-01
... improper lubrication or dressing. In addition, visual examination for wear and broken wires shall be made... HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Personnel Hoisting Wire Ropes § 57.19023 Examinations. (a) At least once every fourteen calendar days, each wire rope in service...
30 CFR 57.19023 - Examinations.
Code of Federal Regulations, 2012 CFR
2012-07-01
... improper lubrication or dressing. In addition, visual examination for wear and broken wires shall be made... HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Personnel Hoisting Wire Ropes § 57.19023 Examinations. (a) At least once every fourteen calendar days, each wire rope in service...
30 CFR 57.19023 - Examinations.
Code of Federal Regulations, 2014 CFR
2014-07-01
... improper lubrication or dressing. In addition, visual examination for wear and broken wires shall be made... HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Personnel Hoisting Wire Ropes § 57.19023 Examinations. (a) At least once every fourteen calendar days, each wire rope in service...
Zhang, Juwei; Tan, Xiaojiang; Zheng, Pengbo
2017-01-01
Electromagnetic methods are commonly employed to detect wire rope discontinuities. However, determining the residual strength of wire rope based on the quantitative recognition of discontinuities remains problematic. We have designed a prototype device based on the residual magnetic field (RMF) of ferromagnetic materials, which overcomes the disadvantages associated with in-service inspections, such as large volume, inconvenient operation, low precision, and poor portability by providing a relatively small and lightweight device with improved detection precision. A novel filtering system consisting of the Hilbert-Huang transform and compressed sensing wavelet filtering is presented. Digital image processing was applied to achieve the localization and segmentation of defect RMF images. The statistical texture and invariant moment characteristics of the defect images were extracted as the input of a radial basis function neural network. Experimental results show that the RMF device can detect defects in various types of wire rope and prolong the service life of test equipment by reducing the friction between the detection device and the wire rope by accommodating a high lift-off distance. PMID:28300790
30 CFR 56.19023 - Examinations.
Code of Federal Regulations, 2011 CFR
2011-07-01
... lubrication or dressing. In addition, visual examination for wear and broken wires shall be made at stress... HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Personnel Hoisting Wire Ropes § 56.19023 Examinations. (a) At least once every fourteen calendar days, each wire rope in service shall be...
30 CFR 75.1433 - Examinations.
Code of Federal Regulations, 2011 CFR
2011-07-01
... addition, visual examination for wear and broken wires shall be made at stress points, including the area... SAFETY STANDARDS-UNDERGROUND COAL MINES Hoisting and Mantrips Wire Ropes § 75.1433 Examinations. (a) At least once every fourteen calendar days, each wire rope in service shall be visually examined along its...
30 CFR 75.1433 - Examinations.
Code of Federal Regulations, 2013 CFR
2013-07-01
... addition, visual examination for wear and broken wires shall be made at stress points, including the area... SAFETY STANDARDS-UNDERGROUND COAL MINES Hoisting and Mantrips Wire Ropes § 75.1433 Examinations. (a) At least once every fourteen calendar days, each wire rope in service shall be visually examined along its...
30 CFR 75.1433 - Examinations.
Code of Federal Regulations, 2014 CFR
2014-07-01
... addition, visual examination for wear and broken wires shall be made at stress points, including the area... SAFETY STANDARDS-UNDERGROUND COAL MINES Hoisting and Mantrips Wire Ropes § 75.1433 Examinations. (a) At least once every fourteen calendar days, each wire rope in service shall be visually examined along its...
30 CFR 75.1433 - Examinations.
Code of Federal Regulations, 2012 CFR
2012-07-01
... addition, visual examination for wear and broken wires shall be made at stress points, including the area... SAFETY STANDARDS-UNDERGROUND COAL MINES Hoisting and Mantrips Wire Ropes § 75.1433 Examinations. (a) At least once every fourteen calendar days, each wire rope in service shall be visually examined along its...
30 CFR 56.19023 - Examinations.
Code of Federal Regulations, 2014 CFR
2014-07-01
... lubrication or dressing. In addition, visual examination for wear and broken wires shall be made at stress... HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Personnel Hoisting Wire Ropes § 56.19023 Examinations. (a) At least once every fourteen calendar days, each wire rope in service shall be...
30 CFR 56.19023 - Examinations.
Code of Federal Regulations, 2013 CFR
2013-07-01
... lubrication or dressing. In addition, visual examination for wear and broken wires shall be made at stress... HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Personnel Hoisting Wire Ropes § 56.19023 Examinations. (a) At least once every fourteen calendar days, each wire rope in service shall be...
30 CFR 56.19023 - Examinations.
Code of Federal Regulations, 2012 CFR
2012-07-01
... lubrication or dressing. In addition, visual examination for wear and broken wires shall be made at stress... HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Personnel Hoisting Wire Ropes § 56.19023 Examinations. (a) At least once every fourteen calendar days, each wire rope in service shall be...
Research on wire rope stress distribution of WR-CVT
NASA Astrophysics Data System (ADS)
Zhang, Wu; Guo, Wei; Zhang, Chuanwei; Lu, Zhengxiong; Xu, Xiaobin
2017-10-01
A wire rope continuously variable transmissions (WR-CVT) has been introduced in the paper, in view of its less research, this paper mainly studied the stress distribution of 6×7+IWS bending wire rope. The results shown that the wire stress is layered distribution in each section, the stress at the outer strand center wire and outer strand side wire was the greatest, the stress value of the outer strand side wire and metal block circular notch is second. As the transmission ratio decreases, the wire stress decreases, which is related to the pulley working radius increases. Compared with the section A1, the stress value on the section A2 is smaller, mainly because the section A2 is not in contact with the metal block or the contact pressure is small. This study provides a basis for the study of fatigue and wears failure of WR-CVT components.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 1014 (incorporated by reference, see § 195.01-3). (d) All lifelines shall be of steel or bronze wire rope. Steel wire rope shall be either inherently corrosion-resistant, or made so by galvanizing or...
Code of Federal Regulations, 2011 CFR
2011-10-01
... 1014 (incorporated by reference, see § 195.01-3). (d) All lifelines shall be of steel or bronze wire rope. Steel wire rope shall be either inherently corrosion-resistant, or made so by galvanizing or...
46 CFR 132.365 - Emergency outfits.
Code of Federal Regulations, 2014 CFR
2014-10-01
... belt or a suitable harness. (3) One Type II or Type III flashlight constructed and marked in accordance...) Lifelines must be of steel or bronze wire rope. Steel wire rope must be either inherently corrosion...
46 CFR 163.002-11 - Materials.
Code of Federal Regulations, 2011 CFR
2011-10-01
... hoist must be made of machine cut steel or machine cut bronze, or must be of a design of equivalent... hoist must be a corrosion-resistant wire rope other than galvanized wire rope. (c) Corrosion-resistant...
46 CFR 163.002-11 - Materials.
Code of Federal Regulations, 2010 CFR
2010-10-01
... hoist must be made of machine cut steel or machine cut bronze, or must be of a design of equivalent... hoist must be a corrosion-resistant wire rope other than galvanized wire rope. (c) Corrosion-resistant...
Code of Federal Regulations, 2011 CFR
2011-10-01
...-3). (d) All lifelines shall be of steel or bronze wire rope. Steel wire ropes shall be either... less than 50 feet in length. The assembled lifeline shall have a minimum breaking strength of 1,500...
Code of Federal Regulations, 2014 CFR
2014-10-01
...-3). (d) All lifelines shall be of steel or bronze wire rope. Steel wire ropes shall be either... less than 50 feet in length. The assembled lifeline shall have a minimum breaking strength of 1,500...
Code of Federal Regulations, 2012 CFR
2012-10-01
...-3). (d) All lifelines shall be of steel or bronze wire rope. Steel wire ropes shall be either... less than 50 feet in length. The assembled lifeline shall have a minimum breaking strength of 1,500...
Code of Federal Regulations, 2013 CFR
2013-10-01
...-3). (d) All lifelines shall be of steel or bronze wire rope. Steel wire ropes shall be either... less than 50 feet in length. The assembled lifeline shall have a minimum breaking strength of 1,500...
46 CFR 169.717 - Fireman's outfit.
Code of Federal Regulations, 2013 CFR
2013-10-01
... Inspection; (2) One lifeline with a belt or a suitable harness; (3) One approved flame safety lamp; (4) One... accessible locations. (c) Lifelines must be of steel or bronze wire rope. Steel wire rope must be either...
46 CFR 169.717 - Fireman's outfit.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Inspection; (2) One lifeline with a belt or a suitable harness; (3) One approved flame safety lamp; (4) One... accessible locations. (c) Lifelines must be of steel or bronze wire rope. Steel wire rope must be either...
46 CFR 169.717 - Fireman's outfit.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Inspection; (2) One lifeline with a belt or a suitable harness; (3) One approved flame safety lamp; (4) One... accessible locations. (c) Lifelines must be of steel or bronze wire rope. Steel wire rope must be either...
46 CFR 169.717 - Fireman's outfit.
Code of Federal Regulations, 2012 CFR
2012-10-01
... Inspection; (2) One lifeline with a belt or a suitable harness; (3) One approved flame safety lamp; (4) One... accessible locations. (c) Lifelines must be of steel or bronze wire rope. Steel wire rope must be either...
46 CFR 35.30-20 - Emergency equipment-TB/ALL
Code of Federal Regulations, 2012 CFR
2012-10-01
... belt or a suitable harness. (3) One, Type II or Type III, flashlight constructed and marked in... Charge, Marine Inspection. (e) Lifelines shall be of steel or bronze wire rope. Steel wire rope shall be...
46 CFR 35.30-20 - Emergency equipment-TB/ALL
Code of Federal Regulations, 2010 CFR
2010-10-01
... belt or a suitable harness. (3) One, Type II or Type III, flashlight constructed and marked in... Charge, Marine Inspection. (e) Lifelines shall be of steel or bronze wire rope. Steel wire rope shall be...
46 CFR 35.30-20 - Emergency equipment-TB/ALL
Code of Federal Regulations, 2011 CFR
2011-10-01
... belt or a suitable harness. (3) One, Type II or Type III, flashlight constructed and marked in... Charge, Marine Inspection. (e) Lifelines shall be of steel or bronze wire rope. Steel wire rope shall be...
46 CFR 35.30-20 - Emergency equipment-TB/ALL
Code of Federal Regulations, 2014 CFR
2014-10-01
... belt or a suitable harness. (3) One, Type II or Type III, flashlight constructed and marked in... Charge, Marine Inspection. (e) Lifelines shall be of steel or bronze wire rope. Steel wire rope shall be...
46 CFR 35.30-20 - Emergency equipment-TB/ALL
Code of Federal Regulations, 2013 CFR
2013-10-01
... belt or a suitable harness. (3) One, Type II or Type III, flashlight constructed and marked in... Charge, Marine Inspection. (e) Lifelines shall be of steel or bronze wire rope. Steel wire rope shall be...
Research of x-ray nondestructive detector for high-speed running conveyor belt with steel wire ropes
NASA Astrophysics Data System (ADS)
Wang, Junfeng; Miao, Changyun; Wang, Wei; Lu, Xiaocui
2008-03-01
An X-ray nondestructive detector for high-speed running conveyor belt with steel wire ropes is researched in the paper. The principle of X-ray nondestructive testing (NDT) is analyzed, the general scheme of the X-ray nondestructive testing system is proposed, and the nondestructive detector for high-speed running conveyor belt with steel wire ropes is developed. The hardware of system is designed with Xilinx's VIRTEX-4 FPGA that embeds PowerPC and MAC IP core, and its network communication software based on TCP/IP protocol is programmed by loading LwIP to PowerPC. The nondestructive testing of high-speed conveyor belt with steel wire ropes and network transfer function are implemented. It is a strong real-time system with rapid scanning speed, high reliability and remotely nondestructive testing function. The nondestructive detector can be applied to the detection of product line in industry.
Design of dual energy x-ray detector for conveyor belt with steel wire ropes
NASA Astrophysics Data System (ADS)
Dai, Yue; Miao, Changyun; Rong, Feng
2009-07-01
A dual energy X-ray detector for conveyor belt with steel wire ropes is researched in the paper. Conveyor belt with steel wire ropes is one of primary transfer equipments in modern production. The traditional test methods like electromagnetic induction principle could not display inner image of steel wire ropes directly. So X-ray detection technology has used to detect the conveyor belt. However the image was not so clear by the interference of the rubber belt. Therefore, the dualenergy X-ray detection technology with subtraction method is developed to numerically remove the rubber belt from radiograph, thus improving the definition of the ropes image. The purpose of this research is to design a dual energy Xray detector that could make the operator easier to found the faulty of the belt. This detection system is composed of Xray source, detector controlled by FPGA chip, PC for running image processing system and so on. With the result of the simulating, this design really improved the capability of the staff to test the conveyor belt.
Code of Federal Regulations, 2012 CFR
2012-10-01
... withstand and operate in excess of the breaking strength of the strongest section or wire to be used in any... application of a load equal to the nominal breaking strength of the strongest section or wire rope to be used... or for trailing objects, where the wire rope or cable is payed out beneath the surface and becomes...
Code of Federal Regulations, 2014 CFR
2014-10-01
... withstand and operate in excess of the breaking strength of the strongest section or wire to be used in any... application of a load equal to the nominal breaking strength of the strongest section or wire rope to be used... or for trailing objects, where the wire rope or cable is payed out beneath the surface and becomes...
Code of Federal Regulations, 2013 CFR
2013-10-01
... withstand and operate in excess of the breaking strength of the strongest section or wire to be used in any... application of a load equal to the nominal breaking strength of the strongest section or wire rope to be used... or for trailing objects, where the wire rope or cable is payed out beneath the surface and becomes...
View of main hoist wire rope drum and brakes, open ...
View of main hoist wire rope drum and brakes, open contact boards are in view at the far right wall - Puget Sound Naval Shipyard, Portal Gantry Crane No. 42, Pier 5, Farragut Avenue, Bremerton, Kitsap County, WA
Research on wire rope deformation distribution of WR-CVT
NASA Astrophysics Data System (ADS)
Zhang, Wu; Guo, Wei; Zhang, Chuanwei; Lu, Zhengxiong; Xu, Xiaobin
2017-07-01
A wire rope continuously variable transmissions (WR-CVT) has been introduced in the paper, in view of its less research, this paper mainly studied the deformation distribution of 6×7+IWS bending wire rope. The results shown that in the same section, half of the side strands are in a stretched state and half are in a compressed state. When the transmission ratio i=2.35, the maximum deformation and the minimum deformation are decrease when section U1 to U2, U3 transition. Wire deformation distribution when the transmission ratio i=0.42 is similar to that of i=0.2.35. Wire deformation amount and the deformation difference decrease as the transmission ratio decreases, this shows that the increase in the bending radius of the wire will make the wire deformation more uniform, and the reduction of the deformation difference will also reduce the wear. This study provides a basis for the study of fatigue and wears failure of WR-CVT components.
46 CFR 163.002-11 - Materials.
Code of Federal Regulations, 2012 CFR
2012-10-01
... hoist must be a corrosion-resistant wire rope other than galvanized wire rope. (c) Corrosion-resistant materials. Materials of a pilot hoist that are not in watertight enclosures must be— (1) Corrosion-resistant or must be treated to be corrosion-resistant; and (2) Galvanically compatible with each other...
46 CFR 163.002-11 - Materials.
Code of Federal Regulations, 2014 CFR
2014-10-01
... hoist must be a corrosion-resistant wire rope other than galvanized wire rope. (c) Corrosion-resistant materials. Materials of a pilot hoist that are not in watertight enclosures must be— (1) Corrosion-resistant or must be treated to be corrosion-resistant; and (2) Galvanically compatible with each other...
46 CFR 163.002-11 - Materials.
Code of Federal Regulations, 2013 CFR
2013-10-01
... hoist must be a corrosion-resistant wire rope other than galvanized wire rope. (c) Corrosion-resistant materials. Materials of a pilot hoist that are not in watertight enclosures must be— (1) Corrosion-resistant or must be treated to be corrosion-resistant; and (2) Galvanically compatible with each other...
49 CFR 393.102 - What are the minimum performance criteria for cargo securement devices and systems?
Code of Federal Regulations, 2010 CFR
2010-10-01
... chains, wire rope, steel strapping, synthetic webbing, and cordage) and other attachment or fastening... acceleration in a lateral direction. (2) Working Load limit. Tiedown assemblies (including chains, wire rope, steel strapping, synthetic webbing, and cordage) and other attachment or fastening devices used to...
49 CFR 393.102 - What are the minimum performance criteria for cargo securement devices and systems?
Code of Federal Regulations, 2011 CFR
2011-10-01
... chains, wire rope, steel strapping, synthetic webbing, and cordage) and other attachment or fastening... acceleration in a lateral direction. (2) Working Load limit. Tiedown assemblies (including chains, wire rope, steel strapping, synthetic webbing, and cordage) and other attachment or fastening devices used to...
Code of Federal Regulations, 2014 CFR
2014-10-01
... 1014 (incorporated by reference, see § 195.01-3). (d) All lifelines shall be of steel or bronze wire rope. Steel wire rope shall be either inherently corrosion-resistant, or made so by galvanizing or... breaking strength of 1,500 pounds. (e) All equipment shall be maintained in an operative condition, and it...
Code of Federal Regulations, 2012 CFR
2012-10-01
... 1014 (incorporated by reference, see § 195.01-3). (d) All lifelines shall be of steel or bronze wire rope. Steel wire rope shall be either inherently corrosion-resistant, or made so by galvanizing or... breaking strength of 1,500 pounds. (e) All equipment shall be maintained in an operative condition, and it...
Code of Federal Regulations, 2013 CFR
2013-10-01
... 1014 (incorporated by reference, see § 195.01-3). (d) All lifelines shall be of steel or bronze wire rope. Steel wire rope shall be either inherently corrosion-resistant, or made so by galvanizing or... breaking strength of 1,500 pounds. (e) All equipment shall be maintained in an operative condition, and it...
Kim, Ju-Won; Park, Seunghee
2018-01-02
In this study, a magnetic flux leakage (MFL) method, known to be a suitable non-destructive evaluation (NDE) method for continuum ferromagnetic structures, was used to detect local damage when inspecting steel wire ropes. To demonstrate the proposed damage detection method through experiments, a multi-channel MFL sensor head was fabricated using a Hall sensor array and magnetic yokes to adapt to the wire rope. To prepare the damaged wire-rope specimens, several different amounts of artificial damages were inflicted on wire ropes. The MFL sensor head was used to scan the damaged specimens to measure the magnetic flux signals. After obtaining the signals, a series of signal processing steps, including the enveloping process based on the Hilbert transform (HT), was performed to better recognize the MFL signals by reducing the unexpected noise. The enveloped signals were then analyzed for objective damage detection by comparing them with a threshold that was established based on the generalized extreme value (GEV) distribution. The detected MFL signals that exceed the threshold were analyzed quantitatively by extracting the magnetic features from the MFL signals. To improve the quantitative analysis, damage indexes based on the relationship between the enveloped MFL signal and the threshold value were also utilized, along with a general damage index for the MFL method. The detected MFL signals for each damage type were quantified by using the proposed damage indexes and the general damage indexes for the MFL method. Finally, an artificial neural network (ANN) based multi-stage pattern recognition method using extracted multi-scale damage indexes was implemented to automatically estimate the severity of the damage. To analyze the reliability of the MFL-based automated wire rope NDE method, the accuracy and reliability were evaluated by comparing the repeatedly estimated damage size and the actual damage size.
29 CFR 1926.1414 - Wire rope-selection and installation criteria.
Code of Federal Regulations, 2014 CFR
2014-07-01
... sockets must be attached to the unloaded dead end of the rope only, except that the use of devices specifically designed for dead-ending rope in a wedge socket is permitted. (g) Socketing must be done in the...
29 CFR 1926.1414 - Wire rope-selection and installation criteria.
Code of Federal Regulations, 2012 CFR
2012-07-01
... sockets must be attached to the unloaded dead end of the rope only, except that the use of devices specifically designed for dead-ending rope in a wedge socket is permitted. (g) Socketing must be done in the...
29 CFR 1926.1414 - Wire rope-selection and installation criteria.
Code of Federal Regulations, 2013 CFR
2013-07-01
... sockets must be attached to the unloaded dead end of the rope only, except that the use of devices specifically designed for dead-ending rope in a wedge socket is permitted. (g) Socketing must be done in the...
Synthetic rope applications in Appalachian logging
Ben D. Spong; Jingxin Wang
2008-01-01
New ultra-high molecular weight polyethylene rope has shown good results as a replacement for wire rope in logging applications in the western United States. A single case study trial was performed in Appalachian forest conditions to assess the appropriateness of this technology for hardwood logging applications. The study focused on use of the rope in West Virginia...
49 CFR 393.124 - What are the rules for securing concrete pipe?
Code of Federal Regulations, 2010 CFR
2010-10-01
... place by blocks and/or wedges; and (iii) Every pipe in the bottom tier must also be held firmly in... not secured individually with a tiedown, then: (A) Either one 1/2-inch diameter chain or wire rope, or two 3/8-inch diameter chain or wire rope, must be placed longitudinally over the group of pipes; (B...
49 CFR 393.124 - What are the rules for securing concrete pipe?
Code of Federal Regulations, 2014 CFR
2014-10-01
... place by blocks and/or wedges; and (iii) Every pipe in the bottom tier must also be held firmly in... not secured individually with a tiedown, then: (A) Either one 1/2-inch diameter chain or wire rope, or two 3/8-inch diameter chain or wire rope, must be placed longitudinally over the group of pipes; (B...
49 CFR 393.124 - What are the rules for securing concrete pipe?
Code of Federal Regulations, 2011 CFR
2011-10-01
... place by blocks and/or wedges; and (iii) Every pipe in the bottom tier must also be held firmly in... not secured individually with a tiedown, then: (A) Either one 1/2-inch diameter chain or wire rope, or two 3/8-inch diameter chain or wire rope, must be placed longitudinally over the group of pipes; (B...
49 CFR 393.124 - What are the rules for securing concrete pipe?
Code of Federal Regulations, 2013 CFR
2013-10-01
... place by blocks and/or wedges; and (iii) Every pipe in the bottom tier must also be held firmly in... not secured individually with a tiedown, then: (A) Either one 1/2-inch diameter chain or wire rope, or two 3/8-inch diameter chain or wire rope, must be placed longitudinally over the group of pipes; (B...
49 CFR 393.124 - What are the rules for securing concrete pipe?
Code of Federal Regulations, 2012 CFR
2012-10-01
... place by blocks and/or wedges; and (iii) Every pipe in the bottom tier must also be held firmly in... not secured individually with a tiedown, then: (A) Either one 1/2-inch diameter chain or wire rope, or two 3/8-inch diameter chain or wire rope, must be placed longitudinally over the group of pipes; (B...
A novel method for harmless disposal and resource reutilization of steel wire rope sludges.
Zhang, Li; Liu, Yang-Sheng
2016-10-01
Rapid development of steel wire rope industry has led to the generation of large quantities of pickling sludge, which causes significant ecological problems and considerable negative environmental effects. In this study, a novel method was proposed for harmless disposal and resource reutilization of the steel wire rope sludge. Based on the method, two steel wire rope sludges (the Pb sludge and the Zn sludge) were firstly extracted by hydrochloric or sulfuric acid and then mixed with the hydrochloride acid extracting solution of aluminum skimmings to produce composite polyaluminum ferric flocculants. The optimum conditions (acid concentration, w/v ratio, reaction time, and reaction temperature) for acid extraction of the sludges were studied. Results showed that 97.03 % of Pb sludge and 96.20 % of Zn sludge were extracted. Leaching potential of the residues after acid extraction was evaluated, and a proposed treatment for the residues had been instructed. The obtained flocculant products were used to purify the real domestic wastewater and showed an equivalent or better performance than the commercial ones. This method is environmental-friendly and cost-effective when compared with the conventional sludge treatments.
The theoretical background to BS7167: 1990 - specification for Bordeaux connections
NASA Astrophysics Data System (ADS)
Gorley, T. A. E.
1992-03-01
The theoretical background to the specification of Bordeaux connections (components of lifting gear used to join together wire rope and a chain, or two lengths of wire rope, where the joined lengths have to run over a sheave as in the case of grabbing cranes) is documented. Decisions taken in the drafting of earlier specifications are not documented. The design criteria for BS7167:1990 are addressed. The various parts of the Bordeaux connection specified in the standard are discussed in turn: the link portion, the rope portion, and the grab shackle. Some tests on the new design undertaken by the Health and Safety Executive confirm the new design criteria to be adequate for the strengths of rope to be used with this component.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-12
... copying at the OSHA Docket Office. You may also contact Theda Kenney at the address below to obtain a copy of the ICR. FOR FURTHER INFORMATION CONTACT: Theda Kenney or Todd Owen, Directorate of Standards and..., the angle upon which it is based, and the number of legs if more than one. Wire rope and wire-rope...
29 CFR (non - mandatory) Appendix A to Subpart L of Part 1926-Scaffold Specifications
Code of Federal Regulations, 2010 CFR
2010-07-01
... equivalent in strength to at least 1/2 inch (1.3 cm) diameter improved plow steel wire rope. (s) Float (ship... wire or synthetic rope, and shall be supported by angle irons attached to brackets welded to the steel... inch lumber; or 11/4 inch × 1/8 inch structural angle iron; or 1 inch × .070 inch wall steel tubing; or...
29 CFR (non - mandatory) appendix A to Subpart L of Part 1926-Scaffold Specifications
Code of Federal Regulations, 2011 CFR
2011-07-01
... equivalent in strength to at least 1/2 inch (1.3 cm) diameter improved plow steel wire rope. (s) Float (ship... wire or synthetic rope, and shall be supported by angle irons attached to brackets welded to the steel... inch lumber; or 11/4 inch × 1/8 inch structural angle iron; or 1 inch × .070 inch wall steel tubing; or...
Orion MPCV Service Module Avionics Ring Pallet Testing, Correlation, and Analysis
NASA Technical Reports Server (NTRS)
Staab, Lucas; Akers, James; Suarez, Vicente; Jones, Trevor
2012-01-01
The NASA Orion Multi-Purpose Crew Vehicle (MPCV) is being designed to replace the Space Shuttle as the main manned spacecraft for the agency. Based on the predicted environments in the Service Module avionics ring, an isolation system was deemed necessary to protect the avionics packages carried by the spacecraft. Impact, sinusoidal, and random vibration testing were conducted on a prototype Orion Service Module avionics pallet in March 2010 at the NASA Glenn Research Center Structural Dynamics Laboratory (SDL). The pallet design utilized wire rope isolators to reduce the vibration levels seen by the avionics packages. The current pallet design utilizes the same wire rope isolators (M6-120-10) that were tested in March 2010. In an effort to save cost and schedule, the Finite Element Models of the prototype pallet tested in March 2010 were correlated. Frequency Response Function (FRF) comparisons, mode shape and frequency were all part of the correlation process. The non-linear behavior and the modeling the wire rope isolators proved to be the most difficult part of the correlation process. The correlated models of the wire rope isolators were taken from the prototype design and integrated into the current design for future frequency response analysis and component environment specification.
29 CFR 1926.251 - Rigging equipment for material handling.
Code of Federal Regulations, 2010 CFR
2010-07-01
..., shall consist of one continuous piece without knot or splice. (iii) Eyes in wire rope bridles, slings... splices shall contain at least three full tucks, and short splices shall contain at least six full tucks... tails shall project at least six rope diameters beyond the last full tuck. For fiber ropes 1-inch...
Experimental study on vertical static stiffnesses of polycal wire rope isolators
NASA Astrophysics Data System (ADS)
Balaji, P. S.; Moussa, Leblouba; Khandoker, Noman; Yuk Shyh, Ting; Rahman, M. E.; Hieng Ho, Lau
2017-07-01
Wire rope isolator is one of the most effective isolation system that can be used to attenuate the vibration disturbances and shocks during the operation of machineries. This paper presents the results of investigation on static elastic stiffnesses (both in tension and in compression) of Polycal Wire Rope Isolator (PWRI) under quasi-static monotonic loading conditions. It also studied effect of variations in height and width of PWRI on its static stiffnesses. Suitable experimental setup was designed and manufactured to meet the test conditions. The results show that their elastic stiffnesses for both tension and compression loading conditions are highly influenced by their geometric dimensions. It is found that their compressive stiffness reduced by 55% for an increment of 20% in their height to width ratio. Therefore, the stiffness of PWRI can be fine-tuned by controlling their dimensions according to the requirements of the application.
Quantitative Inspection of Remanence of Broken Wire Rope Based on Compressed Sensing.
Zhang, Juwei; Tan, Xiaojiang
2016-08-25
Most traditional strong magnetic inspection equipment has disadvantages such as big excitation devices, high weight, low detection precision, and inconvenient operation. This paper presents the design of a giant magneto-resistance (GMR) sensor array collection system. The remanence signal is collected to acquire two-dimensional magnetic flux leakage (MFL) data on the surface of wire ropes. Through the use of compressed sensing wavelet filtering (CSWF), the image expression of wire ropes MFL on the surface was obtained. Then this was taken as the input of the designed back propagation (BP) neural network to extract three kinds of MFL image geometry features and seven invariant moments of defect images. Good results were obtained. The experimental results show that nondestructive inspection through the use of remanence has higher accuracy and reliability compared with traditional inspection devices, along with smaller volume, lighter weight and higher precision.
Quantitative Inspection of Remanence of Broken Wire Rope Based on Compressed Sensing
Zhang, Juwei; Tan, Xiaojiang
2016-01-01
Most traditional strong magnetic inspection equipment has disadvantages such as big excitation devices, high weight, low detection precision, and inconvenient operation. This paper presents the design of a giant magneto-resistance (GMR) sensor array collection system. The remanence signal is collected to acquire two-dimensional magnetic flux leakage (MFL) data on the surface of wire ropes. Through the use of compressed sensing wavelet filtering (CSWF), the image expression of wire ropes MFL on the surface was obtained. Then this was taken as the input of the designed back propagation (BP) neural network to extract three kinds of MFL image geometry features and seven invariant moments of defect images. Good results were obtained. The experimental results show that nondestructive inspection through the use of remanence has higher accuracy and reliability compared with traditional inspection devices, along with smaller volume, lighter weight and higher precision. PMID:27571077
30 CFR 75.1400-3 - Daily examination of hoisting equipment.
Code of Federal Regulations, 2012 CFR
2012-07-01
... examination of the rope for wear, broken wires, and corrosion, especially at excessive strain points such as... of the head sheaves to check for broken flanges, defective bearings, rope alignment, and proper...
30 CFR 75.1400-3 - Daily examination of hoisting equipment.
Code of Federal Regulations, 2010 CFR
2010-07-01
... examination of the rope for wear, broken wires, and corrosion, especially at excessive strain points such as... of the head sheaves to check for broken flanges, defective bearings, rope alignment, and proper...
30 CFR 75.1400-3 - Daily examination of hoisting equipment.
Code of Federal Regulations, 2013 CFR
2013-07-01
... examination of the rope for wear, broken wires, and corrosion, especially at excessive strain points such as... of the head sheaves to check for broken flanges, defective bearings, rope alignment, and proper...
30 CFR 75.1400-3 - Daily examination of hoisting equipment.
Code of Federal Regulations, 2014 CFR
2014-07-01
... examination of the rope for wear, broken wires, and corrosion, especially at excessive strain points such as... of the head sheaves to check for broken flanges, defective bearings, rope alignment, and proper...
30 CFR 75.1400-3 - Daily examination of hoisting equipment.
Code of Federal Regulations, 2011 CFR
2011-07-01
... examination of the rope for wear, broken wires, and corrosion, especially at excessive strain points such as... of the head sheaves to check for broken flanges, defective bearings, rope alignment, and proper...
Practical Applications of Cables and Ropes in the ISS Countermeasures System
NASA Technical Reports Server (NTRS)
Svetlik, Randall G.; Moore, Cherice; Williams, Antony
2017-01-01
National Aeronautics and Space Administration (NASA) uses exercise countermeasures on the International Space Station (ISS) to maintain crew health and combat the negative effects of long-duration spaceflight on the human body. Most ISS exercise countermeasures system (CMS) equipment rely heavily on the use of textile and wire ropes to transmit resistive loads and provide stability in a microgravity environment. For a variety of reasons, including challenges in simulating microgravity environments for testing and limits on time available for life cycle testing, the textiles and wire ropes have contributed significantly to on-orbit planned and unplanned maintenance time. As a result, continued ground testing and on-orbit experience since the first expedition on the ISS in 2000 provide valuable data and lessons learned in materials selection, applications, and design techniques to increase service life of these ropes. This paper will present a review of the development and failure history of textile and wire ropes for four exercise countermeasure systems-the Treadmill with Vibration Isolation and Stabilization (TVIS) System, Cycle Ergometer with Vibration Isolation and Stabilization (CEVIS) System, Interim Resistive Exercise Device (IRED), and the Advanced Resistive Exercise Device (ARED)-to identify lessons learned in order to improve future systems. These lessons learned, paired with thorough testing on the ground, offer a forward path towards reduced maintenance time and up-mass for future space missions.
Wire Rope Failure on the Guppy Winch
NASA Technical Reports Server (NTRS)
Figert, John
2016-01-01
On January 6, 2016 at El Paso, the Guppy winch motor was changed. After completion of the operational checks, the load bar was being reinstalled on the cargo pallet when the motor control FORWARD relay failed in the energized position. The pallet was pinned at all locations (each pin has a load capacity of 16,000 lbs.) while the winch was running. The wire rope snapped before aircraft power could be removed. After disassembly, the fractured wire rope was shipped to ES4 lab for further characterization of the wire rope portion of the failure. The system was being operated without a clear understanding of the system capability and function. The proximate cause was the failure of the K48 -Forward Winch Control Relay in the energized position, which allowed the motor to continuously run without command from the hand controller, and operation of the winch system with both controllers connected to the system. This prevented the emergency stop feature on the hand controller from functioning as designed. An electrical checkout engineering work instruction was completed and identified the failed relay and confirmed the emergency stop only paused the system when the STOP button on both connected hand controllers were depressed simultaneously. The winch system incorporates a torque limiting clutch. It is suspected that the clutch did not slip and the motor did not stall or overload the current limiter. Aircraft Engineering is looking at how to change the procedures to provide a checkout of the clutch and set to a slip torque limit appropriate to support operations.
Code of Federal Regulations, 2010 CFR
2010-10-01
... change seasonally according to the different conservation needs of the different overfished species... any rollers, bobbins, or other material encircling or tied along the length of the footrope. (C) Small... mesh. (J) Trawl fishing line. A length of chain, rope, or wire rope in the bottom front end of a trawl...
Learning the Ropes with Electricity
ERIC Educational Resources Information Center
Carrier, Sarah; Rex, Ted
2013-01-01
This article presents a lesson plan that uses materials such as rope, drinking water, and straws in a classroom activity to teach elementary students about electrical circuits in a "hands on/minds on" fashion. Students first experiment with bulbs, wires, and switches, then they do an activity with simulating electricity through a circuit…
30 CFR 77.1403 - Daily examination of hoisting equipment.
Code of Federal Regulations, 2014 CFR
2014-07-01
...: (a) Elevators. (1) A visual examination of the ropes for wear, broken wires, and corrosion.... (1) An examination of the rope fastenings for defects; (2) An examination of sheaves for broken... automatic controls and brakes required under § 77.1401. (Sec. 101, Federal Mine Safety and Health Act of...
30 CFR 77.1403 - Daily examination of hoisting equipment.
Code of Federal Regulations, 2013 CFR
2013-07-01
...: (a) Elevators. (1) A visual examination of the ropes for wear, broken wires, and corrosion.... (1) An examination of the rope fastenings for defects; (2) An examination of sheaves for broken... automatic controls and brakes required under § 77.1401. (Sec. 101, Federal Mine Safety and Health Act of...
30 CFR 77.1403 - Daily examination of hoisting equipment.
Code of Federal Regulations, 2011 CFR
2011-07-01
...: (a) Elevators. (1) A visual examination of the ropes for wear, broken wires, and corrosion.... (1) An examination of the rope fastenings for defects; (2) An examination of sheaves for broken... automatic controls and brakes required under § 77.1401. (Sec. 101, Federal Mine Safety and Health Act of...
30 CFR 77.1403 - Daily examination of hoisting equipment.
Code of Federal Regulations, 2010 CFR
2010-07-01
...: (a) Elevators. (1) A visual examination of the ropes for wear, broken wires, and corrosion.... (1) An examination of the rope fastenings for defects; (2) An examination of sheaves for broken... automatic controls and brakes required under § 77.1401. (Sec. 101, Federal Mine Safety and Health Act of...
30 CFR 77.1403 - Daily examination of hoisting equipment.
Code of Federal Regulations, 2012 CFR
2012-07-01
...: (a) Elevators. (1) A visual examination of the ropes for wear, broken wires, and corrosion.... (1) An examination of the rope fastenings for defects; (2) An examination of sheaves for broken... automatic controls and brakes required under § 77.1401. (Sec. 101, Federal Mine Safety and Health Act of...
NASA Astrophysics Data System (ADS)
Melentjev, Vladimir S.; Gvozdev, Alexander S.
2018-01-01
Improving the reliability of modern turbine engines is actual task. This is achieved due to prevent a vibration damage of the operating blades. On the department of structure and design of aircraft engines have accumulated a lot of experimental data on the protection of the blades of the gas turbine engine from a vibration. In this paper we proposed a method for calculating the characteristics of wire rope dampers in the root attachment of blade of a gas turbine engine. The method is based on the use of the finite element method and transient analysis. Contact interaction (Lagrange-Euler method) between the compressor blade and the disc of the rotor has been taken into account. Contribution of contact interaction between details in damping of the system was measured. The proposed method provides a convenient way for the iterative selection of the required parameters the wire rope elastic-damping element. This element is able to provide the necessary protection from the vibration for the blade of a gas turbine engine.
Code of Federal Regulations, 2012 CFR
2012-10-01
... by reference, see § 96.01-3). (d) All lifelines shall be of steel or bronze wire rope. Steel wire... breaking strength of 1,500 pounds. (e) All equipment shall be maintained in an operative condition, and it...
Code of Federal Regulations, 2013 CFR
2013-10-01
... by reference, see § 96.01-3). (d) All lifelines shall be of steel or bronze wire rope. Steel wire... breaking strength of 1,500 pounds. (e) All equipment shall be maintained in an operative condition, and it...
Code of Federal Regulations, 2014 CFR
2014-10-01
... by reference, see § 96.01-3). (d) All lifelines shall be of steel or bronze wire rope. Steel wire... breaking strength of 1,500 pounds. (e) All equipment shall be maintained in an operative condition, and it...
Code of Federal Regulations, 2011 CFR
2011-10-01
... by reference, see § 96.01-3). (d) All lifelines shall be of steel or bronze wire rope. Steel wire... breaking strength of 1,500 pounds. (e) All equipment shall be maintained in an operative condition, and it...
Evaluation of the LMA (Trade Name) Series of Wire Rope Testing Instruments
1985-09-30
NSWC TR 85-388 EVALUATION OF THE LMATM SERIES OF WIRE N ROPE TESTING INSTRUMENTS N BY PAUL M. GAMMELL (NSWC) LARRY D. UNDERBAKKE (NCEL) RESEARCH AND...TECHNOLOGY DEPARTMENT 30 SEPTEMBER 1985’ < DTIC l LECTE Aji~p ro t lu f j t) I c rv I o. s ( st rhtI IiT oi i ts n m itedi1 8 1 JON- NAVAL SURFACE...AUTHOR(S) Gammell, Paul M. (NSWC) and Underbakke, Larry D. (NCEL) 13a. TYPE OF REPORT 13b. TIME COVERED 14. DATE OF REPORT (Year, Month, Day) S. PAGE
Dynamic modeling and experiments on the coupled vibrations of building and elevator ropes
NASA Astrophysics Data System (ADS)
Yang, Dong-Ho; Kim, Ki-Young; Kwak, Moon K.; Lee, Seungjun
2017-03-01
This study is concerned with the theoretical modelling and experimental verification of the coupled vibrations of building and elevator ropes. The elevator ropes consist of a main rope which supports the cage and the compensation rope which is connected to the compensation sheave. The elevator rope is a flexible wire with a low damping, so it is prone to vibrations. In the case of a high-rise building, the rope length also increases significantly, so that the fundamental frequency of the elevator rope approaches the fundamental frequency of the building thus increasing the possibility of resonance. In this study, the dynamic model for the analysis of coupled vibrations of building and elevator ropes was derived by using Hamilton's principle, where the cage motion was also considered. An experimental testbed was built to validate the proposed dynamic model. It was found that the experimental results are in good agreement with the theoretical predictions thus validating the proposed dynamic model. The proposed model was then used to predict the vibrations of real building and elevator ropes.
46 CFR 199.153 - Survival craft launching and recovery arrangements using falls and a winch.
Code of Federal Regulations, 2011 CFR
2011-10-01
... wire must be of rotation-resistant and corrosion-resistant steel wire rope. (c) The breaking strength of each fall wire and each attachment used on the fall must be at least six times the load imparted... levers. (f) Each winch drum must be arranged so the fall wire winds onto the drum in one or more level...
46 CFR 108.553 - Survival craft launching and recovery arrangements using falls and a winch.
Code of Federal Regulations, 2011 CFR
2011-10-01
...) Each fall wire must be of rotation-resistant and corrosion-resistant steel wire rope. (b) The breaking strength of each fall wire and each attachment used on the fall must be at least six times the load... levers. (e) Each winch drum must be arranged so the fall wire winds onto the drum in a level wrap, and a...
46 CFR 133.153 - Survival craft launching and recovery arrangements using falls and a winch.
Code of Federal Regulations, 2010 CFR
2010-10-01
...) Each fall wire must be of rotation-resistant and corrosion-resistant steel wire rope. (b) The breaking strength of each fall wire and each attachment used on the fall must be at least six times the load.... (e) Each winch drum must be arranged so the fall wire winds onto the drum in a level wrap. A multiple...
46 CFR 133.153 - Survival craft launching and recovery arrangements using falls and a winch.
Code of Federal Regulations, 2011 CFR
2011-10-01
...) Each fall wire must be of rotation-resistant and corrosion-resistant steel wire rope. (b) The breaking strength of each fall wire and each attachment used on the fall must be at least six times the load.... (e) Each winch drum must be arranged so the fall wire winds onto the drum in a level wrap. A multiple...
46 CFR 108.553 - Survival craft launching and recovery arrangements using falls and a winch.
Code of Federal Regulations, 2010 CFR
2010-10-01
...) Each fall wire must be of rotation-resistant and corrosion-resistant steel wire rope. (b) The breaking strength of each fall wire and each attachment used on the fall must be at least six times the load... levers. (e) Each winch drum must be arranged so the fall wire winds onto the drum in a level wrap, and a...
46 CFR 199.153 - Survival craft launching and recovery arrangements using falls and a winch.
Code of Federal Regulations, 2010 CFR
2010-10-01
... wire must be of rotation-resistant and corrosion-resistant steel wire rope. (c) The breaking strength of each fall wire and each attachment used on the fall must be at least six times the load imparted... levers. (f) Each winch drum must be arranged so the fall wire winds onto the drum in one or more level...
Experimental characterization of shape memory alloy actuator cables
NASA Astrophysics Data System (ADS)
Biggs, Daniel B.; Shaw, John A.
2016-04-01
Wire rope (or cables) are a fundamental structural element in many engineering applications. Recently, there has been growing interest in stranding NiTi wires into cables to scale up the adaptive properties of NiTi tension elements and to make use of the desirable properties of wire rope. Exploratory experiments were performed to study the actuation behavior of two NiTi shape memory alloy cables and straight monofilament wire of the same material. The specimens were held under various dead loads ranging from 50 MPa to 400 MPa and thermally cycled 25 times from 140°C to 5°C at a rate of 12°C/min. Performance metrics of actuation stroke, residual strain, and work output were measured and compared between specimen types. The 7x7 cable exhibited similar actuation to the single straight wire, but with slightly longer stroke and marginally more shakedown, while maintaining equivalent specific work output. This leads to the conclusion that the 7x7 cable effectively scaled up the adaptive properties the straight wire. Under loads below 150 MPa, the 1x27 cable had up to double the actuation stroke and work output, but exhibited larger shakedown and poorer performance when loaded higher.
Method of making a catalytic reactor for automobile
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vroman, W.R.
1976-09-07
A catalytic reactor is made by providing a generally cylindrical catalytic substrate of oval transverse section and clamping the same between paired housing shells to form a housing of oval section spaced from the substrate by means of a pair of wire mesh ropes seated within a corresponding pair of grooves extending around the periphery of the substrate at axially spaced locations. Each rope is compacted from a matrix of multiple layers of resilient stainless steel knitted wire and is interlocked with the housing by means of a pair of inwardly opening channels of the housing spaced axially by anmore » inwardly projecting rib of the housing. The grooves in the substrate are pressed radially into the latter while the same is in a plastic uncured condition, thereby to compact and reinforce the grooves to withstand the localized compressional force of the ropes seated therein after the substrate is cured and hardened and clamped between the housing shells.« less
Experiments and Dynamic Finite Element Analysis of a Wire-Rope Rockfall Protective Fence
NASA Astrophysics Data System (ADS)
Tran, Phuc Van; Maegawa, Koji; Fukada, Saiji
2013-09-01
The imperative need to protect structures in mountainous areas against rockfall has led to the development of various protection methods. This study introduces a new type of rockfall protection fence made of posts, wire ropes, wire netting and energy absorbers. The performance of this rock fence was verified in both experiments and dynamic finite element analysis. In collision tests, a reinforced-concrete block rolled down a natural slope and struck the rock fence at the end of the slope. A specialized system of measuring instruments was employed to accurately measure the acceleration of the block without cable connection. In particular, the performance of two energy absorbers, which contribute also to preventing wire ropes from breaking, was investigated to determine the best energy absorber. In numerical simulation, a commercial finite element code having explicit dynamic capabilities was employed to create models of the two full-scale tests. To facilitate simulation, certain simplifying assumptions for mechanical data of each individual component of the rock fence and geometrical data of the model were adopted. Good agreement between numerical simulation and experimental data validated the numerical simulation. Furthermore, the results of numerical simulation helped highlight limitations of the testing method. The results of numerical simulation thus provide a deeper understanding of the structural behavior of individual components of the rock fence during rockfall impact. More importantly, numerical simulations can be used not only as supplements to or substitutes for full-scale tests but also in parametric study and design.
Sericin removal from raw Bombyx mori silk scaffolds of high hierarchical order.
Teuschl, Andreas Herbert; van Griensven, Martijn; Redl, Heinz
2014-05-01
Silk fibroin has previously been described as a promising candidate for ligament tissue engineering (TE) approaches. For biocompatibility reasons, silkworm silk requires removal of sericin, which can elicit adverse immune responses in the human body. One disadvantage of the required degumming process is the alteration of the silk fiber structural properties, which can hinder textile engineering of high order hierarchical structures. Therefore, the aim of this study was to find a way to remove sericin from a compact and highly ordered raw silk fiber matrix. The wire rope design of the test model scaffold comprises several levels of geometric hierarchy. Commonly used degumming solutions fail in removing sericin in this wire rope design. Weight loss measurements, picric acid and carmine staining as well as scanning electron microscopy demonstrated that the removal of sericin from the model scaffold of a wire rope design can be achieved through a borate buffer-based system. Furthermore, the borate buffer degummed silks were shown to be nontoxic and did not alter cell proliferation behavior. The possibility to remove sericin after the textile engineering process has taken place eases the production of highly ordered scaffold structures and may expand the use of silk as scaffold material in further TE and regenerative medicine applications.
Detail of conning tower atop the submarine. Note the wire ...
Detail of conning tower atop the submarine. Note the wire rope wrapped around the base of the tower, which may have been used in an attempt to pull the submarine offshore. - Sub Marine Explorer, Located along the beach of Isla San Telmo, Pearl Islands, Isla San Telmo, Former Panama Canal Zone, CZ
46 CFR 133.153 - Survival craft launching and recovery arrangements using falls and a winch.
Code of Federal Regulations, 2012 CFR
2012-10-01
... falls and a winch. 133.153 Section 133.153 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY... launching and recovery arrangements using falls and a winch. Survival craft launching and recovery...) Each fall wire must be of rotation-resistant and corrosion-resistant steel wire rope. (b) The breaking...
46 CFR 108.553 - Survival craft launching and recovery arrangements using falls and a winch.
Code of Federal Regulations, 2013 CFR
2013-10-01
... falls and a winch. 108.553 Section 108.553 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY... craft launching and recovery arrangements using falls and a winch. Survival craft launching and recovery...) Each fall wire must be of rotation-resistant and corrosion-resistant steel wire rope. (b) The breaking...
46 CFR 133.153 - Survival craft launching and recovery arrangements using falls and a winch.
Code of Federal Regulations, 2014 CFR
2014-10-01
... falls and a winch. 133.153 Section 133.153 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY... launching and recovery arrangements using falls and a winch. Survival craft launching and recovery...) Each fall wire must be of rotation-resistant and corrosion-resistant steel wire rope. (b) The breaking...
46 CFR 133.153 - Survival craft launching and recovery arrangements using falls and a winch.
Code of Federal Regulations, 2013 CFR
2013-10-01
... falls and a winch. 133.153 Section 133.153 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY... launching and recovery arrangements using falls and a winch. Survival craft launching and recovery...) Each fall wire must be of rotation-resistant and corrosion-resistant steel wire rope. (b) The breaking...
NASA Technical Reports Server (NTRS)
Rumble, C. V.; Driscoll, K. L. (Inventor)
1974-01-01
An electrical wire is reported along whose length loops are formed at intervals and retained in a plastic capsule that allows unfolding of the loop when tension is exerted on the opposite ends of the wire. The capsule is formed by encompassing each loop with a sleeve of heat shrinkable synthetic plastic material which overlaps the loop and heat shrinking the overlapping portions. Thus, a length of electrical wire is formed which stores extra lengths of wire in the quantity needed to match the expected stretching of materials or elements such as ropes, cords and the like of high elongation to which the electrical wire may be attached.
Horst, K; Garving, C; Thometzki, T; Lichte, P; Knobe, M; Dienstknecht, T; Hofman, M; Pape, H-C
2017-04-01
The aim of this study was to address the inconsistency regarding the operative treatment of Rockwood type III acromioclavicular joint separation. We compared results after single- and double TightRope ® reduction with results after acromioclavicular transfixation via K-wires only and additional ligament augmentation in acute acromioclavicular (AC) joint separations graded Rockwood type III, and hypothesized that the TightRope ® technique leads to better clinical and radiological results. We conducted a retrospective clinical cohort study and included 42 consecutive patients (mean age 43 years [24-66]) diagnosed and operatively treated between 2004 and 2012 (mean follow-up was 54.6 months [15-118]). Specific shoulder scores as well as scores reflecting the patients' overall mental and physical health status were used. Radiological evaluation was also performed. The SF12 test revealed comparability between all subgroups. Specific shoulder tests and a visual analogue scale demonstrated comparable results. Radiographic measurements showed a significant reduction in the AC distance and CC distance after surgery in all subgroups. The early complication rate was 9.5% for all patients, while late complications occurred in 14.3% of all cases. Compared to the established methods, the operative TightRope ® procedures represent a safe alternative in Rockwood III injuries. All investigated techniques predominantly led to good and excellent clinical results in acute Rockwood type III AC joint instabilities. Avoidance of material removal and shorter hospital stays appear to speak in favour for the TightRope ® technique. IV. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
46 CFR 71.25-25 - Hull equipment.
Code of Federal Regulations, 2013 CFR
2013-10-01
... testing and examination of chains, rings, hooks, shackles, swivels, and blocks; (5) Certification of the testing and examination of wire rope; (6) Certification of the heat treatment of chains, rings, hooks...
46 CFR 91.25-25 - Hull equipment.
Code of Federal Regulations, 2014 CFR
2014-10-01
... examination of chains, rings, hooks, shackles, swivels, and blocks; (5) Certification of the testing and examination of wire rope; (6) Certification of the heat-treatment of chains, rings, hooks, shackles, and...
46 CFR 91.25-25 - Hull equipment.
Code of Federal Regulations, 2013 CFR
2013-10-01
... examination of chains, rings, hooks, shackles, swivels, and blocks; (5) Certification of the testing and examination of wire rope; (6) Certification of the heat-treatment of chains, rings, hooks, shackles, and...
46 CFR 91.25-25 - Hull equipment.
Code of Federal Regulations, 2012 CFR
2012-10-01
... examination of chains, rings, hooks, shackles, swivels, and blocks; (5) Certification of the testing and examination of wire rope; (6) Certification of the heat-treatment of chains, rings, hooks, shackles, and...
46 CFR 71.25-25 - Hull equipment.
Code of Federal Regulations, 2014 CFR
2014-10-01
... testing and examination of chains, rings, hooks, shackles, swivels, and blocks; (5) Certification of the testing and examination of wire rope; (6) Certification of the heat treatment of chains, rings, hooks...
46 CFR 71.25-25 - Hull equipment.
Code of Federal Regulations, 2011 CFR
2011-10-01
... testing and examination of chains, rings, hooks, shackles, swivels, and blocks; (5) Certification of the testing and examination of wire rope; (6) Certification of the heat treatment of chains, rings, hooks...
46 CFR 91.25-25 - Hull equipment.
Code of Federal Regulations, 2011 CFR
2011-10-01
... examination of chains, rings, hooks, shackles, swivels, and blocks; (5) Certification of the testing and examination of wire rope; (6) Certification of the heat-treatment of chains, rings, hooks, shackles, and...
46 CFR 71.25-25 - Hull equipment.
Code of Federal Regulations, 2012 CFR
2012-10-01
... testing and examination of chains, rings, hooks, shackles, swivels, and blocks; (5) Certification of the testing and examination of wire rope; (6) Certification of the heat treatment of chains, rings, hooks...
Critical Decay Index at the Onset of Solar Eruptions
NASA Astrophysics Data System (ADS)
Zuccarello, F. P.; Aulanier, G.; Gilchrist, S. A.
2015-12-01
Magnetic flux ropes are topological structures consisting of twisted magnetic field lines that globally wrap around an axis. The torus instability model predicts that a magnetic flux rope of major radius R undergoes an eruption when its axis reaches a location where the decay index -d({ln}{B}{ex})/d({ln}R) of the ambient magnetic field Bex is larger than a critical value. In the current-wire model, the critical value depends on the thickness and time evolution of the current channel. We use magnetohydrodynamic simulations to investigate whether the critical value of the decay index at the onset of the eruption is affected by the magnetic flux rope’s internal current profile and/or by the particular pre-eruptive photospheric dynamics. The evolution of an asymmetric, bipolar active region is driven by applying different classes of photospheric motions. We find that the critical value of the decay index at the onset of the eruption is not significantly affected by either the pre-erupitve photospheric evolution of the active region or the resulting different magnetic flux ropes. As in the case of the current-wire model, we find that there is a “critical range” [1.3-1.5], rather than a “critical value” for the onset of the torus instability. This range is in good agreement with the predictions of the current-wire model, despite the inclusion of line-tying effects and the occurrence of tether-cutting magnetic reconnection.
Interior view of 175 ton hoist house looking at the ...
Interior view of 175 ton hoist house looking at the exterior casing for the wire rope spools. - Marshall Space Flight Center, Saturn V Dynamic Test Facility, East Test Area, Huntsville, Madison County, AL
The Australian Disaster Rescue Manual. Second Edition
1988-01-01
manufacture, wires and strands are either coated with lubricant to prevent corrosion and friction in the rope, or are galvanised. The size of Steel Wire...have an adverse affect on steel. Periodical inspection for corrosion is necessary. - 25 2.18 Records The results of all inspection, including details of...small holes 4n fibro, iron, alluminium can be repaired with greater speed using a sealant. Mineral fibre reinforced asphaltic sealing compounds such
43 CFR 15.2 - Removal or destruction of natural features and marine life.
Code of Federal Regulations, 2012 CFR
2012-10-01
... marine invertebrates, seaweeds, grasses, or any soil, rock, artifacts, stones or other materials. No... this Preserve. No rope, wire or other contrivance shall be attached to any coral, rock or other...
29 CFR 1926.104 - Safety belts, lifelines, and lanyards.
Code of Federal Regulations, 2010 CFR
2010-07-01
... be subjected to cutting or abrasion, shall be a minimum of 7/8-inch wire core manila rope. For all... or pressed steel, cadmium plated in accordance with type 1, Class B plating specified in Federal...
29 CFR 1926.104 - Safety belts, lifelines, and lanyards.
Code of Federal Regulations, 2011 CFR
2011-07-01
... be subjected to cutting or abrasion, shall be a minimum of 7/8-inch wire core manila rope. For all... or pressed steel, cadmium plated in accordance with type 1, Class B plating specified in Federal...
47 CFR 76.806 - Pre-termination access to cable home wiring.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 47 Telecommunication 4 2011-10-01 2011-10-01 false Pre-termination access to cable home wiring. 76... access to cable home wiring. (a) Prior to termination of service, a customer may: install or provide for the installation of their own cable home wiring; or connect additional home wiring, splitters or other...
47 CFR 76.806 - Pre-termination access to cable home wiring.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 47 Telecommunication 4 2014-10-01 2014-10-01 false Pre-termination access to cable home wiring. 76... access to cable home wiring. (a) Prior to termination of service, a customer may: install or provide for the installation of their own cable home wiring; or connect additional home wiring, splitters or other...
47 CFR 76.806 - Pre-termination access to cable home wiring.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 47 Telecommunication 4 2013-10-01 2013-10-01 false Pre-termination access to cable home wiring. 76... access to cable home wiring. (a) Prior to termination of service, a customer may: install or provide for the installation of their own cable home wiring; or connect additional home wiring, splitters or other...
30 CFR 77.1435 - Load end attachments.
Code of Federal Regulations, 2010 CFR
2010-07-01
... MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES Personnel... where use of other materials is a design feature, zinc (spelter) shall be used for socketing wire ropes. Design feature means either the manufacturer's original design or a design approved by a registered...
VIEW NORTH OF PRESTRESS TRACK CENTERHEMP STORAGE BUILDING 77 (1920) ...
VIEW NORTH OF PRE-STRESS TRACK CENTER-HEMP STORAGE BUILDING 77 (1920) ROPE WAREHOUSE 43 (1941) BEHIND IT STORAGE SHED 44 (1953) IN FRONT - John A. Roebling's Sons Company & American Steel & Wire Company, South Broad, Clark, Elmer, Mott & Hudson Streets, Trenton, Mercer County, NJ
29 CFR 1926.753 - Hoisting and rigging.
Code of Federal Regulations, 2011 CFR
2011-07-01
... (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Steel Erection § 1926.753 Hoisting and rigging. (a... used in steel erection activities shall be visually inspected prior to each shift by a competent person... and latches for deformation, chemical damage, cracks, or wear; (F) Wire rope reeving for compliance...
15. DETAIL VIEW OF SAWMILL POWER HOUSE FOUNDATION (CONSTRUCTED IN ...
15. DETAIL VIEW OF SAWMILL POWER HOUSE FOUNDATION (CONSTRUCTED IN 1909) SHOWING THE WIRE-ROPE AND RAILROAD RAILS USED AS REINFORCEMENT IN THE CONCRETE. THIS SAME MODE OF REINFORCEMENT WAS USED IN THE DAM. - Hume Lake Dam, Sequioa National Forest, Hume, Fresno County, CA
30 CFR 75.1434 - Retirement criteria.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Hoisting and Mantrips Wire Ropes § 75.1434 Retirement... structure; (f) Heat damage from any source; (g) Diameter reduction due to wear that exceeds six percent of...
30 CFR 75.1436 - Drum end attachment.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Hoisting and Mantrips Wire Ropes § 75.1436 Drum end... full turn around the drum spoke; (2) Securely by clips after making one full turn around the shaft, if...
Code of Federal Regulations, 2013 CFR
2013-10-01
... working load limit. (c) Vehicle structures and anchor points. Vehicle structures, floors, walls, decks... tiedown assemblies. Tiedown assemblies (including chains, wire rope, steel strapping, synthetic webbing... . . . Must conform to . . . (1) Steel strapping 1 2 Standard Specification for Strapping, Flat Steel and...
Code of Federal Regulations, 2012 CFR
2012-10-01
... working load limit. (c) Vehicle structures and anchor points. Vehicle structures, floors, walls, decks... tiedown assemblies. Tiedown assemblies (including chains, wire rope, steel strapping, synthetic webbing... . . . Must conform to . . . (1) Steel strapping 1,2 Standard Specification for Strapping, Flat Steel and...
49 CFR 393.102 - What are the minimum performance criteria for cargo securement devices and systems?
Code of Federal Regulations, 2012 CFR
2012-10-01
... chains, wire rope, steel strapping, synthetic webbing, and cordage) and other attachment or fastening..., steel strapping, synthetic webbing, and cordage) and other attachment or fastening devices used to... contained within the structure of the vehicle. Securement systems must provide a downward force equivalent...
49 CFR 393.102 - What are the minimum performance criteria for cargo securement devices and systems?
Code of Federal Regulations, 2014 CFR
2014-10-01
... chains, wire rope, steel strapping, synthetic webbing, and cordage) and other attachment or fastening..., steel strapping, synthetic webbing, and cordage) and other attachment or fastening devices used to... contained within the structure of the vehicle. Securement systems must provide a downward force equivalent...
Code of Federal Regulations, 2014 CFR
2014-10-01
... working load limit. (c) Vehicle structures and anchor points. Vehicle structures, floors, walls, decks... tiedown assemblies. Tiedown assemblies (including chains, wire rope, steel strapping, synthetic webbing... . . . Must conform to . . . (1) Steel strapping 1 2 Standard Specification for Strapping, Flat Steel and...
49 CFR 393.102 - What are the minimum performance criteria for cargo securement devices and systems?
Code of Federal Regulations, 2013 CFR
2013-10-01
... chains, wire rope, steel strapping, synthetic webbing, and cordage) and other attachment or fastening..., steel strapping, synthetic webbing, and cordage) and other attachment or fastening devices used to... contained within the structure of the vehicle. Securement systems must provide a downward force equivalent...
46 CFR 31.10-16 - Inspection and certification of cargo gear-TB/ALL.
Code of Federal Regulations, 2010 CFR
2010-10-01
...; (4) Certification of the testing and examination of chains, rings, hooks, shackles, swivels, and blocks; (5) Certification of the testing and examination of wire rope; (6) Certification of the heat treatment of chains, rings, hooks, shackles, and swivels which require such treatment; and, (7...
46 CFR 31.10-16 - Inspection and certification of cargo gear-TB/ALL.
Code of Federal Regulations, 2012 CFR
2012-10-01
...; (4) Certification of the testing and examination of chains, rings, hooks, shackles, swivels, and blocks; (5) Certification of the testing and examination of wire rope; (6) Certification of the heat treatment of chains, rings, hooks, shackles, and swivels which require such treatment; and, (7...
46 CFR 31.10-16 - Inspection and certification of cargo gear-TB/ALL.
Code of Federal Regulations, 2013 CFR
2013-10-01
...; (4) Certification of the testing and examination of chains, rings, hooks, shackles, swivels, and blocks; (5) Certification of the testing and examination of wire rope; (6) Certification of the heat treatment of chains, rings, hooks, shackles, and swivels which require such treatment; and, (7...
46 CFR 31.10-16 - Inspection and certification of cargo gear-TB/ALL.
Code of Federal Regulations, 2011 CFR
2011-10-01
...; (4) Certification of the testing and examination of chains, rings, hooks, shackles, swivels, and blocks; (5) Certification of the testing and examination of wire rope; (6) Certification of the heat treatment of chains, rings, hooks, shackles, and swivels which require such treatment; and, (7...
46 CFR 31.10-16 - Inspection and certification of cargo gear-TB/ALL.
Code of Federal Regulations, 2014 CFR
2014-10-01
...; (4) Certification of the testing and examination of chains, rings, hooks, shackles, swivels, and blocks; (5) Certification of the testing and examination of wire rope; (6) Certification of the heat treatment of chains, rings, hooks, shackles, and swivels which require such treatment; and, (7...
Filter line wiring designs in aircraft
NASA Astrophysics Data System (ADS)
Rowe, Richard M.
1990-10-01
The paper presents a harness design using a filter-line wire technology and appropriate termination methods to help meet high-energy radiated electromagnetic field (HERF) requirements for protection against the adverse effects of EMI on electrical and avionic systems. Filter-line interconnect harnessing systems discussed consist of high-performance wires and cables; when properly wired they suppress conducted and radiated EMI above 100 MHz. Filter-line termination devices include backshell adapters, braid splicers, and shield terminators providing 360-degree low-impedance terminations and enhancing maintainability of the system.
29 CFR 1917.42 - Miscellaneous auxiliary gear.
Code of Federal Regulations, 2010 CFR
2010-07-01
... wire rope used in hoisting or lowering, or in bulling cargo, shall consist of one continuous piece... splices shall consist of at least three full tucks. Short splices shall consist of at least six full tucks... slings. (1) Slings and nets or other combinations of more than one piece of synthetic webbing assembled...
46 CFR 32.02-10 - Rails-TB/ALL.
Code of Federal Regulations, 2013 CFR
2013-10-01
... three courses including the top. The opening below the lowest course shall not be more than 9 inches... be in at least two courses, including the top, approximately evenly spaced. All rails shall consist of solid or tubular sections or chains or wire rope or a combination thereof. (b) Where it can be...
46 CFR 32.02-10 - Rails-TB/ALL.
Code of Federal Regulations, 2012 CFR
2012-10-01
... three courses including the top. The opening below the lowest course shall not be more than 9 inches... be in at least two courses, including the top, approximately evenly spaced. All rails shall consist of solid or tubular sections or chains or wire rope or a combination thereof. (b) Where it can be...
46 CFR 32.02-10 - Rails-TB/ALL.
Code of Federal Regulations, 2014 CFR
2014-10-01
... three courses including the top. The opening below the lowest course shall not be more than 9 inches... be in at least two courses, including the top, approximately evenly spaced. All rails shall consist of solid or tubular sections or chains or wire rope or a combination thereof. (b) Where it can be...
Code of Federal Regulations, 2010 CFR
2010-10-01
... tiedown assemblies. Tiedown assemblies (including chains, wire rope, steel strapping, synthetic webbing... . . . Must conform to . . . (1) Steel strapping 1,2 Standard Specification for Strapping, Flat Steel and... Association of Chain Manufacturers' Welded Steel Chain Specifications, dated September 28, 2005. 4 (3) Webbing...
Code of Federal Regulations, 2011 CFR
2011-10-01
... tiedown assemblies. Tiedown assemblies (including chains, wire rope, steel strapping, synthetic webbing... . . . Must conform to . . . (1) Steel strapping 1,2 Standard Specification for Strapping, Flat Steel and... Association of Chain Manufacturers' Welded Steel Chain Specifications, dated September 28, 2005. 4 (3) Webbing...
49 CFR 393.7 - Matter incorporated by reference.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Specification for Strapping, Flat Steel and Seals, American Society for Testing and Materials (ASTM), D3953-97, February 1998, incorporation by reference approved for § 393.104(e). (19) Welded Steel Chain Specifications... Association, WSTDA-T1, 1998, incorporation by reference approved for § 393.104(e). (21) Wire Rope Users Manual...
49 CFR 393.7 - Matter incorporated by reference.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Specification for Strapping, Flat Steel and Seals, American Society for Testing and Materials (ASTM), D3953-97, February 1998, incorporation by reference approved for § 393.104(e). (19) Welded Steel Chain Specifications... Association, WSTDA-T1, 1998, incorporation by reference approved for § 393.104(e). (21) Wire Rope Users Manual...
Nautical Education for Offshore Extractive Industries. Support Operations & Seamanship.
ERIC Educational Resources Information Center
Hoffmann, G. L.
This training manual is intended for persons who will be employed on supply vessels or towboats which support ocean-based oil extraction operations. The text deals with the basic skills of marine towing procedures, boat handling, deck maintenance, cargo operations, and rope and wire handling. Additional sections treat the proper attitude of a…
29 CFR 1918.62 - Miscellaneous auxiliary gear.
Code of Federal Regulations, 2010 CFR
2010-07-01
... appendix II to this part. A design safety factor of at least five shall be maintained for the common sizes... cranes, designed to be used with lesser wire rope safety factors; (ii) According to design factors in... pre-slung drafts. (3) Eye splices shall consist of at least three full tucks. Short splices shall...
29 CFR 1918.62 - Miscellaneous auxiliary gear.
Code of Federal Regulations, 2011 CFR
2011-07-01
... appendix II to this part. A design safety factor of at least five shall be maintained for the common sizes... cranes, designed to be used with lesser wire rope safety factors; (ii) According to design factors in... pre-slung drafts. (3) Eye splices shall consist of at least three full tucks. Short splices shall...
29 CFR 1926.104 - Safety belts, lifelines, and lanyards.
Code of Federal Regulations, 2014 CFR
2014-07-01
... be subjected to cutting or abrasion, shall be a minimum of 7/8-inch wire core manila rope. For all other lifeline applications, a minimum of 3/4-inch manila or equivalent, with a minimum breaking... nominal breaking strength of 5,400 pounds. (e) All safety belt and lanyard hardware shall be drop forged...
29 CFR 1926.104 - Safety belts, lifelines, and lanyards.
Code of Federal Regulations, 2012 CFR
2012-07-01
... be subjected to cutting or abrasion, shall be a minimum of 7/8-inch wire core manila rope. For all other lifeline applications, a minimum of 3/4-inch manila or equivalent, with a minimum breaking... nominal breaking strength of 5,400 pounds. (e) All safety belt and lanyard hardware shall be drop forged...
29 CFR 1926.104 - Safety belts, lifelines, and lanyards.
Code of Federal Regulations, 2013 CFR
2013-07-01
... be subjected to cutting or abrasion, shall be a minimum of 7/8-inch wire core manila rope. For all other lifeline applications, a minimum of 3/4-inch manila or equivalent, with a minimum breaking... nominal breaking strength of 5,400 pounds. (e) All safety belt and lanyard hardware shall be drop forged...
Job Grading Standard for Blocker and Bracer WG-4602.
ERIC Educational Resources Information Center
Civil Service Commission, Washington, DC. Bureau of Policies and Standards.
The standard is used to grade nonsupervisor's work involved in blocking, bracing, staying, and securing cargo for shipment by land, sea, or air. It requires skill in constructing, placing, and installing wooden blocks, wedges, bracing structures and other staying devices, as well as skill in securing items using wires, ropes, chains, cables,…
NASA Technical Reports Server (NTRS)
Bredberg, Alan S.
2003-01-01
A versatile cable-dispensing cart can support as many as a few dozen reels of cable, wire, and/or rope. The cart can be adjusted to accommodate reels of various diameters and widths, and can be expanded, contracted, or otherwise reconfigured by use of easily installable and removable parts that can be carried onboard. Among these parts are dispensing rods and a cable guide that enables dispensing of cables without affecting the direction of pull. Individual reels can be mounted on or removed from the cart without affecting the other reels: this feature facilitates the replacement or reuse of partially depleted reels, thereby helping to reduce waste. Multiple cables, wires, or ropes can be dispensed simultaneously. For maneuverability, the cart is mounted on three wheels. Once it has been positioned, the cart is supported by rubber mounts for stability and for prevention of sliding or rolling during dispensing operations. The stability and safety of the cart are enhanced by a low-center-of-gravity design. The cart can readily be disassembled into smaller units for storage or shipping, then reassembled in the desired configuration at a job site.
47 CFR 76.806 - Pre-termination access to cable home wiring.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 4 2010-10-01 2010-10-01 false Pre-termination access to cable home wiring. 76.806 Section 76.806 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Cable Inside Wiring § 76.806 Pre-termination...
43 CFR 15.2 - Removal or destruction of natural features and marine life.
Code of Federal Regulations, 2013 CFR
2013-10-01
... LARGO CORAL REEF PRESERVE § 15.2 Removal or destruction of natural features and marine life. No person... sand, gravel or minerals, corals, sea feathers and fans, shells and shell fish starfishes or other... this Preserve. No rope, wire or other contrivance shall be attached to any coral, rock or other...
43 CFR 15.2 - Removal or destruction of natural features and marine life.
Code of Federal Regulations, 2014 CFR
2014-10-01
... LARGO CORAL REEF PRESERVE § 15.2 Removal or destruction of natural features and marine life. No person... sand, gravel or minerals, corals, sea feathers and fans, shells and shell fish starfishes or other... this Preserve. No rope, wire or other contrivance shall be attached to any coral, rock or other...
43 CFR 15.2 - Removal or destruction of natural features and marine life.
Code of Federal Regulations, 2011 CFR
2011-10-01
... LARGO CORAL REEF PRESERVE § 15.2 Removal or destruction of natural features and marine life. No person... sand, gravel or minerals, corals, sea feathers and fans, shells and shell fish starfishes or other... this Preserve. No rope, wire or other contrivance shall be attached to any coral, rock or other...
43 CFR 15.2 - Removal or destruction of natural features and marine life.
Code of Federal Regulations, 2010 CFR
2010-10-01
... LARGO CORAL REEF PRESERVE § 15.2 Removal or destruction of natural features and marine life. No person... sand, gravel or minerals, corals, sea feathers and fans, shells and shell fish starfishes or other... this Preserve. No rope, wire or other contrivance shall be attached to any coral, rock or other...
29 CFR 782.8 - Special classes of carriers.
Code of Federal Regulations, 2011 CFR
2011-07-01
... subject to its jurisdiction. (New Pittsburgh Coal Co. v. Hocking Valley Ry. Co., 24 I.C.C. 244; Corona Coal Co. v. Secretary of War, 69 I.C.C. 389; Bunker Coal from Alabama to Gulf Ports, 227 I.C.C. 485.) The intrastate delivery of chandleries, including cordage, canvas, repair parts, wire rope, etc., to...
29 CFR 782.8 - Special classes of carriers.
Code of Federal Regulations, 2010 CFR
2010-07-01
... subject to its jurisdiction. (New Pittsburgh Coal Co. v. Hocking Valley Ry. Co., 24 I.C.C. 244; Corona Coal Co. v. Secretary of War, 69 I.C.C. 389; Bunker Coal from Alabama to Gulf Ports, 227 I.C.C. 485.) The intrastate delivery of chandleries, including cordage, canvas, repair parts, wire rope, etc., to...
29 CFR 1926.502 - Fall protection systems criteria and practices.
Code of Federal Regulations, 2011 CFR
2011-07-01
... constitute a projection hazard. (8) Steel banding and plastic banding shall not be used as top rails or... thickness to prevent cuts and lacerations. If wire rope is used for top rails, it shall be flagged at not... paragraph (e) of this section. (1) Connectors shall be drop forged, pressed or formed steel, or made of...
Condition Assessment Aspects of an Asset Management Program
2008-01-01
of a roller gate..................................................................................................49 Figure 11. Torsion in a roller...each component of these structures (filters, drains , motors, wire rope, etc.). This is accomplished by a pre- developed framework that is tailored to...various types of miter gates to account for within the algorithm. Depending on the anchorage system (rigid versus flexible ) and whether the lock is
49 CFR 176.74 - On deck stowage of break-bulk hazardous materials.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 2 2013-10-01 2013-10-01 false On deck stowage of break-bulk hazardous materials... CARRIAGE BY VESSEL General Handling and Stowage § 176.74 On deck stowage of break-bulk hazardous materials... and proper lashing by use of wire rope, strapping or other means, including shoring and bracing, or...
49 CFR 176.74 - On deck stowage of break-bulk hazardous materials.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 49 Transportation 2 2014-10-01 2014-10-01 false On deck stowage of break-bulk hazardous materials... CARRIAGE BY VESSEL General Handling and Stowage § 176.74 On deck stowage of break-bulk hazardous materials... and proper lashing by use of wire rope, strapping or other means, including shoring and bracing, or...
49 CFR 176.74 - On deck stowage of break-bulk hazardous materials.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 2 2011-10-01 2011-10-01 false On deck stowage of break-bulk hazardous materials... CARRIAGE BY VESSEL General Handling and Stowage § 176.74 On deck stowage of break-bulk hazardous materials... and proper lashing by use of wire rope, strapping or other means, including shoring and bracing, or...
49 CFR 176.74 - On deck stowage of break-bulk hazardous materials.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 49 Transportation 2 2012-10-01 2012-10-01 false On deck stowage of break-bulk hazardous materials... CARRIAGE BY VESSEL General Handling and Stowage § 176.74 On deck stowage of break-bulk hazardous materials... and proper lashing by use of wire rope, strapping or other means, including shoring and bracing, or...
Code of Federal Regulations, 2013 CFR
2013-07-01
... under the load and has both ends, end attachments, eyes or handles on the hook or a single master link... lifting hook. Cable laid endless sling-mechanical joint is a wire rope sling made endless by joining the.... N-184-1.) Handle eye is an opening in a handle of a metal mesh sling shaped to accept a hook...
Code of Federal Regulations, 2014 CFR
2014-07-01
... under the load and has both ends, end attachments, eyes or handles on the hook or a single master link... lifting hook. Cable laid endless sling-mechanical joint is a wire rope sling made endless by joining the.... N-184-1.) Handle eye is an opening in a handle of a metal mesh sling shaped to accept a hook...
Code of Federal Regulations, 2012 CFR
2012-07-01
... under the load and has both ends, end attachments, eyes or handles on the hook or a single master link... lifting hook. Cable laid endless sling-mechanical joint is a wire rope sling made endless by joining the.... N-184-1.) Handle eye is an opening in a handle of a metal mesh sling shaped to accept a hook...
75 FR 8486 - Drawbridge Operation Regulation; Inner Harbor Navigational Canal, New Orleans, LA
Federal Register 2010, 2011, 2012, 2013, 2014
2010-02-25
... Operation Regulation; Inner Harbor Navigational Canal, New Orleans, LA AGENCY: Coast Guard, DHS. ACTION... EHL), at New Orleans, LA. The deviation is necessary to replace the counterweight wire ropes on the... Building Ground Floor, Room W12-140, 1200 New Jersey Avenue, SE., Washington, DC 20590, between 9 a.m. and...
Underwater Acoustic Positioning Systems for MEC Detection and Reacquisition Operations
2016-01-22
Paris, TX and 123 miles northeast of Dallas . Pat Mayse Lake is part of the Former Camp Maxey Formerly Used Defense Site (FUDS) (Figure 2). The lake...the water (Figure 16) while the boat is at idle, and tightening down the braces to lock the pole in place. (Figure 17). A guy-wire (1/4” rope
Whistler mode refraction in highly nonuniform magnetic fields
NASA Astrophysics Data System (ADS)
Urrutia, J. M.; Stenzel, R.
2016-12-01
In a large laboratory plasma the propagation of whistler modes is measured in highly nonuniform magnetic fields created by a current-carrying wires. Ray tracing is not applicable since the wavelength and gradient scale length are comparable. The waves are excited with a loop antenna near the wire. The antenna launches an m=1 helicon mode in a uniform plasma. The total magnetic field consists of a weak uniform background field and a nearly circular field of a straight wire across the background field. A circular loop produces 3D null points and a 2D null line. The whistler wave propagation will be shown. It is relevant to whistler mode propagation in space plasmas near magnetic null-points, small flux ropes, lunar crustal magnetic fields and active wave injection experiments.
Rail Impact Testing. Test Operations Procedure (TOP)
2008-09-15
impact test. The rail impact test is used to verify structural integrity of the test item and the adequacy of the tie-down system and tie-down...strength of provisions, connection and supporting structural frame, paragraph 5.2.3 ** Superscript...parts, to include outriggers and booms) without advanced approval by SDDCTEA. Torque nuts on wire rope clips to their correct value. Torque cable
ERIC Educational Resources Information Center
Graham, Louise B.; Robinson, Ellyn M.
2009-01-01
Two classes from diverse graduate programs merged and melded for a weeklong intensive outdoor experience to learn how to be leaders for an outdoor challenge course. Physical Education graduate students and students in a Counselor Education program together participated in the Challenge Course, co-led by an Exercise Scientist and a Psychologist.…
77 FR 24147 - Drawbridge Operation Regulation; Mile 359.4, Missouri River, Kansas City, MO
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-23
... eight wire rope lifting cables that operate the lift span. This deviation allows the bridge to remain in the closed position while the lift cables are replaced. DATES: This deviation is effective from 10 p.m... cables that operate the lift span are replaced. The closure period will start at 10 p.m. on or about May...
77 FR 28488 - Drawbridge Operation Regulation; Upper Mississippi River, Hannibal, MO
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-15
... lifting cables that operate the lift span. This deviation allows the bridge to remain in the closed position while the lift cables are replaced. DATES: This deviation is effective from 9 a.m. to 3 p.m. on or... wire rope lifting cables that operate the lift span are replaced. The closure period will be from 9 a.m...
49 CFR 393.132 - What are the rules for securing flattened or crushed vehicles?
Code of Federal Regulations, 2011 CFR
2011-10-01
... is prohibited except that such webbing may be used to connect wire rope or chain to anchor points on... or comparable means on four sides which extend to the full height of the load and which block against... comparable means on three sides which extend to the full height of the load and which block against movement...
49 CFR 393.132 - What are the rules for securing flattened or crushed vehicles?
Code of Federal Regulations, 2010 CFR
2010-10-01
... is prohibited except that such webbing may be used to connect wire rope or chain to anchor points on... or comparable means on four sides which extend to the full height of the load and which block against... comparable means on three sides which extend to the full height of the load and which block against movement...
49 CFR 393.132 - What are the rules for securing flattened or crushed vehicles?
Code of Federal Regulations, 2012 CFR
2012-10-01
... is prohibited except that such webbing may be used to connect wire rope or chain to anchor points on... or comparable means on four sides which extend to the full height of the load and which block against... comparable means on three sides which extend to the full height of the load and which block against movement...
49 CFR 393.132 - What are the rules for securing flattened or crushed vehicles?
Code of Federal Regulations, 2014 CFR
2014-10-01
... is prohibited except that such webbing may be used to connect wire rope or chain to anchor points on... or comparable means on four sides which extend to the full height of the load and which block against... comparable means on three sides which extend to the full height of the load and which block against movement...
49 CFR 393.132 - What are the rules for securing flattened or crushed vehicles?
Code of Federal Regulations, 2013 CFR
2013-10-01
... is prohibited except that such webbing may be used to connect wire rope or chain to anchor points on... or comparable means on four sides which extend to the full height of the load and which block against... comparable means on three sides which extend to the full height of the load and which block against movement...
High-Density Terminal Box for Testing Wire Harness
NASA Technical Reports Server (NTRS)
Pierce, W. B.; Collins, W. G.
1982-01-01
Compact terminal box provides access to complex wiring harnesses for testing. Box accommodates more than twice as many wires as previous boxes. Box takes in wires via cable connectors and distributes them to contacts on box face. Instead of separate insulated jacks in metal face panel, box uses pairs of small military-standard metal sockets in precision-drilled plastic panel. Shorting plug provides continuity for wires when not being tested.
Research on burnout fault of moulded case circuit breaker based on finite element simulation
NASA Astrophysics Data System (ADS)
Xue, Yang; Chang, Shuai; Zhang, Penghe; Xu, Yinghui; Peng, Chuning; Shi, Erwei
2017-09-01
In the failure event of molded case circuit breaker, overheating of the molded case near the wiring terminal has a very important proportion. The burnout fault has become an important factor restricting the development of molded case circuit breaker. This paper uses the finite element simulation software to establish the model of molded case circuit breaker by coupling multi-physics field. This model can simulate the operation and study the law of the temperature distribution. The simulation results show that the temperature near the wiring terminal, especially the incoming side of the live wire, of the molded case circuit breaker is much higher than that of the other areas. The steady-state and transient simulation results show that the temperature at the wiring terminals is abnormally increased by increasing the contact resistance of the wiring terminals. This is consistent with the frequent occurrence of burnout of the molded case in this area. Therefore, this paper holds that the burnout failure of the molded case circuit breaker is mainly caused by the abnormal increase of the contact resistance of the wiring terminal.
Orbiter Payload Bay Bucket Hoist Mishap...An Accident We Should Never Forget
NASA Technical Reports Server (NTRS)
Lytle, Bradford P.
2009-01-01
This slide presentation reviews the accident that occurred in 1985 when a bay bucket hoist fell from its stowed position. This accident damaged the orbiter, injured a technician, and delayed the launch. The accident was investigated, and the cause of the accident was determined to be the practice of two-blocking. Two-blocking is the result of hoisting beyond the intended safe upper limit of hook travel to the point of solid contact between the load block and the upper block or hoist/trolley structure. The usual result is immediate failure of the wire rope, due to the ropes being cut by the grooves of the drum or sheaves. The design of the hoist, the inspection, and the operator training were all in part responsible for this failure.
26 CFR 49.4253-8 - Exemption for terminal facilities in case of wire mileage service.
Code of Federal Regulations, 2010 CFR
2010-04-01
... wire mileage service. 49.4253-8 Section 49.4253-8 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT... Communications § 49.4253-8 Exemption for terminal facilities in case of wire mileage service. The taxes imposed by section 4251 do not apply to so much of any amount paid for wire mileage service as is paid for...
26 CFR 49.4253-8 - Exemption for terminal facilities in case of wire mileage service.
Code of Federal Regulations, 2011 CFR
2011-04-01
... wire mileage service. 49.4253-8 Section 49.4253-8 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT... Communications § 49.4253-8 Exemption for terminal facilities in case of wire mileage service. The taxes imposed by section 4251 do not apply to so much of any amount paid for wire mileage service as is paid for...
NASA Technical Reports Server (NTRS)
Li, Y.; Cutright, S.; Dyke, R.; Templeton, J.; Gasbarre, J.; Novak, F.
2015-01-01
The Stratospheric Aerosol and Gas Experiment (SAGE) III - International Space Station (ISS) instrument will be used to study ozone, providing global, long-term measurements of key components of the Earth's atmosphere for the continued health of Earth and its inhabitants. SAGE III is launched into orbit in an inverted configuration on SpaceX;s Falcon 9 launch vehicle. As one of its four supporting elements, a Contamination Monitoring Package (CMP) mounted to the top panel of the Interface Adapter Module (IAM) box experiences high-frequency response due to structural coupling between the two structures during the SpaceX launch. These vibrations, which were initially observed in the IAM Engineering Development Unit (EDU) test and later verified through finite element analysis (FEA) for the SpaceX launch loads, may damage the internal electronic cards and the Thermoelectric Quartz Crystal Microbalance (TQCM) sensors mounted on the CMP. Three-dimensional (3D) vibration isolators were required to be inserted between the CMP and IAM interface in order to attenuate the high frequency vibrations without resulting in any major changes to the existing system. Wire rope isolators were proposed as the isolation system between the CMP and IAM due to the low impact to design. Most 3D isolation systems are designed for compression and roll, therefore little dynamic data was available for using wire rope isolators in an inverted or tension configuration. From the isolator FEA and test results, it is shown that by using the 3D wire rope isolators, the CMP high-frequency responses have been suppressed by several orders of magnitude over a wide excitation frequency range. Consequently, the TQCM sensor responses are well below their qualification environments. It is indicated that these high-frequency responses due to the typical instrument structural coupling can be significantly suppressed by a vibration passive control using the 3D vibration isolator. Thermal and contamination issues were also examined during the isolator selection period for meeting the SAGE III-ISS instrument requirements.
The development of the Garden Banks block 388 FPF mooring system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dove, P.G.S.; Librino, F.; Scovell, D.C.
1995-12-01
This paper discusses work conducted during the design, procurement and installation of Enserch Exploration, Inc.`s Garden Banks 388 FPF mooring system. The design began with the execution of a trade-off study evaluating and comparing previously installed floating production moorings in the Gulf of Mexico, coupled with evaluation of new concepts and emphasis on cost effective solutions. The design effort involved dynamic analysis and wind tunnel and model tank testing, all in accordance with the newly completed API document RP 2FP1. Inspection of various components from the Placid GC-29 FPS moorings (installed in 1987 and recovered in 1990) determined that sectionsmore » of chain, jacketed spiral strand wire rope, submersible buoys and connectors could be reused with suitable refurbishment. The excellent condition of the rig`s onboard winching system also resulted in the reuse of the windlasses, with specified upgrades. Because a sufficient amount of used wire was not available, a bare spiral strand wire rope construction was adopted, including zinc anodes in the new sections, rather than jacketed strand. The lack of cost effective installation vessels in the Gulf of Mexico at the time of the installation bid posed challenges to Enserch. However, an innovative preset mooring installation scheme involving Heeremac`s SSCV Balder on its own moorings was adopted. Since the vessel was already in the Gulf of Mexico on contract for other projects, a cost effective contract was negotiated. The results of this effort led to considerable cost savings for Enserch, compared to conventional FPF mooring systems previously installed in the Gulf of Mexico.« less
29 CFR (non - mandatory) Appendix A to Subpart L of Part 1926-Scaffold Specifications
Code of Federal Regulations, 2014 CFR
2014-07-01
... equivalent in strength to at least 1/2 inch (1.3 cm) diameter improved plow steel wire rope. (s) Float (ship... force. (d) Guardrails shall be as follows: (i) Toprails shall be equivalent in strength to 2 inch by 4 inch lumber; or 11/4 inch × 1/8 inch structural angle iron; or 1 inch × .070 inch wall steel tubing; or...
29 CFR (non - mandatory) Appendix A to Subpart L of Part 1926-Scaffold Specifications
Code of Federal Regulations, 2013 CFR
2013-07-01
... equivalent in strength to at least 1/2 inch (1.3 cm) diameter improved plow steel wire rope. (s) Float (ship... force. (d) Guardrails shall be as follows: (i) Toprails shall be equivalent in strength to 2 inch by 4 inch lumber; or 11/4 inch × 1/8 inch structural angle iron; or 1 inch × .070 inch wall steel tubing; or...
Ocean Acoustic Tomography Mooring Design Study.
1982-04-01
mounted in RP. - RP contains its own power source. - Dead -weight anchor. - Acoustic Release is located in the RP. Configurations 1. - Top buoyancy...float is a steel sphere. icI - USS 3 x 19 jacketed wire rope is used as the tension member. - Anchor is dead -weight. - Acoustic Release is located...Receiver/Satellite Telemetry Moorings (RT) - Receiver depth 1000 - 3500 m. - Ocean depth is 5000 m. - Receiver contains its own power source. - Dead
Mine Hoist Operator Training System. Phase I Report.
1978-11-01
Bodies of Knowledge Function Control speed of conveyances Hold conveyances in position Structural Components Types of brakes : * Disc * Drum - Jaw...Parallel motion Components of each type * Disc / drum * Pads/shoes * Operating mechanisms Operating mediums for braking * Hydraulic/pneumatic * Manual...SHAFT GUIDES Wood El BRAKES Steel Rails El Drum : Wire Rope: Jaw El Full Lock El Parallel Motion El Half Lock El Disc El LEVELS DRIVE MOTORS Single El
50. SOUTHEAST TO SOUTHEAST CORNER OF WELLSERVICE SHED ADDITION ON ...
50. SOUTHEAST TO SOUTHEAST CORNER OF WELL-SERVICE SHED ADDITION ON REAR OF FACTORY BUILDING. HANGING FROM AND LEANING AGAINST THE WALL ARE TOOLS USED IN WATER WELL SERVICE, SUCH AS BAILER, CHAINS, WRENCHES, PULLEYS, ROPE, SAFETY BELT, CHAIN TONGS, AND LEATHER SEALS FOR PISTON DISPLACEMENT PUMPS. CLEARLY VISIBLE ON RAFTERS IS HISTORIC ELECTRICAL WIRING. - Kregel Windmill Company Factory, 1416 Central Avenue, Nebraska City, Otoe County, NE
Wire Crimp Termination Verification Using Ultrasonic Inspection
NASA Technical Reports Server (NTRS)
Perey, Daniel F.; Cramer, K. Elliott; Yost, William T.
2007-01-01
The development of a new ultrasonic measurement technique to quantitatively assess wire crimp terminations is discussed. The amplitude change of a compressional ultrasonic wave propagating through the junction of a crimp termination and wire is shown to correlate with the results of a destructive pull test, which is a standard for assessing crimp wire junction quality. Various crimp junction pathologies such as undercrimping, missing wire strands, incomplete wire insertion, partial insulation removal, and incorrect wire gauge are ultrasonically tested, and their results are correlated with pull tests. Results show that the nondestructive ultrasonic measurement technique consistently (as evidenced with destructive testing) predicts good crimps when ultrasonic transmission is above a certain threshold amplitude level. A physics-based model, solved by finite element analysis, describes the compressional ultrasonic wave propagation through the junction during the crimping process. This model is in agreement within 6% of the ultrasonic measurements. A prototype instrument for applying this technique while wire crimps are installed is also presented. The instrument is based on a two-jaw type crimp tool suitable for butt-splice type connections. Finally, an approach for application to multipin indenter type crimps will be discussed.
Acquisition of Ice-Tethered Profilers with Velocity (ITP-V) Instruments for Future Arctic Studies
2015-09-30
jacketed wire rope tether and end weight should the ice fracture or melt , and to provide modest protection in the event of ice ridging. The profiler...1 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. Acquisition of Ice -Tethered Profilers with Velocity (ITP...evolving thermohaline stratification, the ocean currents and air- ice -sea interactions on time scales of minutes to seasonal and longer. OBJECTIVES
Magnet-wire wrapping tool for integrated circuits
NASA Technical Reports Server (NTRS)
Takahashi, T. H.
1972-01-01
Wire-dispensing tool which resembles mechanical pencil is used to wrap magnet wire around integrated circuit terminals uniformly and securely without damaging insulative coating on wire. Tool is hand-held and easily manipulated to execute wire wrapping movements.
Photovoltaic system with improved AC connections and method of making same
Cioffi, Philip Michael; Todorovic, Maja Harfman; Herzog, Michael Scott; Korman, Charles Steven; Doherty, Donald M.; Johnson, Neil Anthony
2018-02-13
An alternating current (AC) harness for a photovoltaic (PV) system includes a wire assembly having a first end and a second end, the wire assembly having a plurality of lead wires, and at least one AC connection module positioned at a location along a length of the wire assembly between the first end and the second end. Further, the at least one AC connection module includes a first connection terminal electrically coupled to the plurality of lead wires of the wire assembly and constructed to electrically couple the wire assembly with an output of a first PV module of the PV system. The at least one AC connection module also includes a second connection terminal electrically coupled to the plurality of lead wires of the wire assembly and constructed to electrically couple the wire assembly with an output of a second PV module of the PV system.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Takahashi, Takuya; Shibata, Kazunari; Qiu, Jiong, E-mail: takahasi@kusastro.kyoto-u.ac.jp
We propose a mechanism for quasi-periodic oscillations of both coronal mass ejections (CMEs) and flare loops as related to magnetic reconnection in eruptive solar flares. We perform two-dimensional numerical MHD simulations of magnetic flux rope eruption, with three different values of the global Lundquist number. In the low Lundquist number run, no oscillatory behavior is found. In the moderate Lundquist number run, on the other hand, quasi-periodic oscillations are excited both at the bottom of the flux rope and at the flare loop top. In the high Lundquist number run, quasi-periodic oscillations are also excited; in the meanwhile, the dynamicsmore » become turbulent owing to the formation of multiple plasmoids in the reconnection current sheet. In high and moderate Lundquist number runs, thin reconnection jets collide with the flux rope bottom or flare loop top and dig them deeply. Steep oblique shocks are formed as termination shocks where reconnection jets are bent (rather than decelerated) in the horizontal direction, resulting in supersonic backflows. The structure becomes unstable, and quasi-periodic oscillations of supersonic backflows appear at locally confined high-beta regions at both the flux rope bottom and flare loop top. We compare the observational characteristics of quasi-periodic oscillations in erupting flux ropes, post-CME current sheets, flare ribbons, and light curves with corresponding dynamical structures found in our simulation.« less
NASA Astrophysics Data System (ADS)
Takahashi, Takuya; Qiu, Jiong; Shibata, Kazunari
2017-10-01
We propose a mechanism for quasi-periodic oscillations of both coronal mass ejections (CMEs) and flare loops as related to magnetic reconnection in eruptive solar flares. We perform two-dimensional numerical MHD simulations of magnetic flux rope eruption, with three different values of the global Lundquist number. In the low Lundquist number run, no oscillatory behavior is found. In the moderate Lundquist number run, on the other hand, quasi-periodic oscillations are excited both at the bottom of the flux rope and at the flare loop top. In the high Lundquist number run, quasi-periodic oscillations are also excited; in the meanwhile, the dynamics become turbulent owing to the formation of multiple plasmoids in the reconnection current sheet. In high and moderate Lundquist number runs, thin reconnection jets collide with the flux rope bottom or flare loop top and dig them deeply. Steep oblique shocks are formed as termination shocks where reconnection jets are bent (rather than decelerated) in the horizontal direction, resulting in supersonic backflows. The structure becomes unstable, and quasi-periodic oscillations of supersonic backflows appear at locally confined high-beta regions at both the flux rope bottom and flare loop top. We compare the observational characteristics of quasi-periodic oscillations in erupting flux ropes, post-CME current sheets, flare ribbons, and light curves with corresponding dynamical structures found in our simulation.
Report on Investigations of Aviation Wires and Cables, Their Fastenings and Terminal Connections
NASA Technical Reports Server (NTRS)
Sunderlang, C C; Horn, H J; Green, D
1917-01-01
Report presents results that show that it is possible to furnish efficient terminal connections that would allow for repairs for aviation wires and cables and eliminate the use of acid solder and blow torch.
Vrgoč, G; Japjec, M; Jurina, P; Gulan, G; Janković, S; Šebečić, B; Starešinić, M
2015-11-01
Acromioclavicular (AC) joint dislocations usually occur in a young active population as a result of a fall on the shoulder. Rockwood divided these dislocations into six types. Optimal treatment is still a matter of discussion. Many operative techniques have been developed, but the main choice is between open and minimally-invasive arthroscopic procedures. The aim of this study was to compare two different surgical methods on two groups of patients to find out which method is superior in terms of benefit to the patient. The methods were evaluated through objective and subjective scores, with a focus on complications and material costs. A retrospective two-centre study was conducted in patients with acute AC joint dislocation Rockwood types III and V. The two methods conducted were an open procedure using K-wires combined with FiberTape(®) (Arthrex, Naples, USA) (Group 1) and an arthroscopic procedure using the TightRope System(®) (Arthrex, Naples, USA) (Group 2). Groups underwent procedures during a two-year period. Diagnosis was based on the clinical and radiographic examination of both AC joints. Surgical treatment and rehabilitation were performed. Sixteen patients were included in this study: Group 1 comprised 10 patients, all male, average age 41.6 years (range 17-64 years), Rockwood type III (eight patients) and Rockwood type V (two patients); Group 2 had six patients, one female and five male, average age 37.8 years (range 18-58 years), Rockwood type III (two patients) and Rockwood type V (four patients). Time from injury to surgery was shorter and patients needed less time to return to daily activities in Group 1. Duration of the surgical procedure was shorter in Group 2 compared with Group 1. Complications of each method were noted. According to the measured scores and operative outcome between dislocation Rockwood type III and V, no significant difference was found. Implant material used in Group 2 was 4.7 times more expensive than that used in Group 1. Both methods offer many advantages with satisfying evaluated scores. K-wires with FiberTape(®) offer a shorter period for complete recovery and a significantly more cost-effective outcome, whereas the TightRope System(®) offers shorter operative procedure, better cosmetic result and avoidance of intraoperative fluoroscopy. Copyright © 2015 Elsevier Ltd. All rights reserved.
Process for Nondestructive Evaluation of the Quality of a Crimped Wire Connector
NASA Technical Reports Server (NTRS)
Yost, William T. (Inventor); Cramer, Karl E. (Inventor); Perey, Daniel F. (Inventor); Williams, Keith A. (Inventor)
2014-01-01
A process and apparatus for collecting data for nondestructive evaluation of the quality of a crimped wire connector are provided. The process involves providing a crimping tool having an anvil and opposing jaw for crimping a terminal onto a stranded wire, moving the jaw relative to the anvil to close the distance between the jaw and the anvil and thereby compress the terminal against the wire, while transmitting ultrasonic waves that are propagated through the terminal-wire combination and received at a receiving ultrasonic transducer as the jaw is moved relative to the anvil, and detecting and recording the position of the jaw relative to the anvil as a function of time and detecting and recording the amplitude of the ultrasonic wave that is received at the receiving ultrasonic transducer as a function of time as the jaw is moved relative to the anvil.
Anomalous length dependence of conductance of aromatic nanoribbons with amine anchoring groups
NASA Astrophysics Data System (ADS)
Bilić, Ante; Sanvito, Stefano
2012-09-01
Two sets of aromatic nanoribbons, based around a common hexagonal scaffolding, with single and dual terminal amine groups have been considered as potential molecular wires in a junction formed by gold leads. Charge transport through the two-terminal device has been modeled using density functional theory (with and without self-interaction correction) and the nonequilibrium Green's function method. The effects of wire length, multiple terminal contacts, and pathways across the junction have been investigated. For nanoribbons with the oligopyrene motif and conventional single amine terminal groups, an increase in the wire length causes an exponential drop in the conductance. In contrast, for the nanoribbons with the oligoperylene motif and dual amine anchoring groups the predicted conductance rises with the wire length over the whole range of investigated lengths. Only when the effects of self-interaction correction are taken into account, the conductance of the oligoperylene ribbons exhibits saturation for longer members of the series. The oligoperylene nanoribbons, with dual amine groups at both terminals, show the potential to fully harness the highly conjugated system of π molecular orbitals across the junction.
49 CFR 234.239 - Tagging of wires and interference of wires or tags with signal apparatus.
Code of Federal Regulations, 2011 CFR
2011-10-01
... with signal apparatus. 234.239 Section 234.239 Transportation Other Regulations Relating to... Tagging of wires and interference of wires or tags with signal apparatus. Each wire shall be tagged or... of the apparatus. This requirement applies to each wire at each terminal in all housings including...
49 CFR 234.239 - Tagging of wires and interference of wires or tags with signal apparatus.
Code of Federal Regulations, 2010 CFR
2010-10-01
... with signal apparatus. 234.239 Section 234.239 Transportation Other Regulations Relating to... Tagging of wires and interference of wires or tags with signal apparatus. Each wire shall be tagged or... of the apparatus. This requirement applies to each wire at each terminal in all housings including...
A gating grid driver for time projection chambers
NASA Astrophysics Data System (ADS)
Tangwancharoen, S.; Lynch, W. G.; Barney, J.; Estee, J.; Shane, R.; Tsang, M. B.; Zhang, Y.; Isobe, T.; Kurata-Nishimura, M.; Murakami, T.; Xiao, Z. G.; Zhang, Y. F.; SπRIT Collaboration
2017-05-01
A simple but novel driver system has been developed to operate the wire gating grid of a Time Projection Chamber (TPC). This system connects the wires of the gating grid to its driver via low impedance transmission lines. When the gating grid is open, all wires have the same voltage allowing drift electrons, produced by the ionization of the detector gas molecules, to pass through to the anode wires. When the grid is closed, the wires have alternating higher and lower voltages causing the drift electrons to terminate at the more positive wires. Rapid opening of the gating grid with low pickup noise is achieved by quickly shorting the positive and negative wires to attain the average bias potential with N-type and P-type MOSFET switches. The circuit analysis and simulation software SPICE shows that the driver restores the gating grid voltage to 90% of the opening voltage in less than 0.20 μs, for small values of the termination resistors. When tested in the experimental environment of a time projection chamber larger termination resistors were chosen so that the driver opens the gating grid in 0.35 μs. In each case, opening time is basically characterized by the RC constant given by the resistance of the switches and terminating resistors and the capacitance of the gating grid and its transmission line. By adding a second pair of N-type and P-type MOSFET switches, the gating grid is closed by restoring 99% of the original charges to the wires within 3 μs.
Unterkofler, Jan; Merschin, David; Langenbach, Andreas; Ekkernkamp, Axel; Schulz-Drost, Stefan
2017-01-01
Background: The costoclavicular ligament (CCL) provides the most tight stability within the sternoclavicular joint (SCJ), followed by the most cited sternoclavicular ligaments (SCL). Their disruption may cause severe instability of the SCJ. Different treatment options, such as the use of plates, wires or autologous tendons are associated with mainly limited functional outcome. Could a stabilization of CCL next to an anatomic fixation of the SCL provide sufficient reconstruction of the SCJ? Methods: A 58-year-old male showed severe anterior and painful instability of the SCJ following a fall on his shoulder 8 weeks ago. The SCJ had been reconstructed in an open procedure with stabilization of the CCL employing 2 tight ropes and anatomical suture of the SCL. Follow-up was carried out 78 weeks after operation. Results: The reduction of the SCJ was successful. X-ray proved the anatomic position of the SCJ. Pain was decreased in between the first 6 weeks. The patient showed uneventful follow-up and returned to work 6 months after the procedureas a hard working farmer. Conclusions: Innovative stabilization of the CCL with tight ropes additional to a suture of the SCL may enable anatomic reconstruction of the SCJ considering cosmetic and functional results. Celsius.
The Effect of Condensate Inundation on Steam Condensation Heat Transfer to Wire-Wrapped Tubing.
1983-06-01
wrapped in a helical manner. The measured condensing coefficient was approximately three times that predicted by the Nusselt equation for a smooth tube...Du. Em0At Block 20 (continued) --"- condensing coefficient measured for 30 smooth tubes was 0.59 times the Nusselt coefficient calculated for the...of 0.029 was found, while it was 0.061 for the roped tubes. The average condensing coefficient measured for 30 smooth tubes was 0.59 times the Nusselt
NASA Technical Reports Server (NTRS)
Dos Reis, H. L. M.; Vary, A.
1988-01-01
This paper introduces the nature and the underlying rational of the acousto-ultrasonic stress wave factor technique and some of its applications to composite materials and structures. Furthermore, two examples of successful application of the acousto-ultrasonic technique are presented in detail. In the first example, the acousto-ultrasonic technique is used to evaluate the adhesive bond strength between rubber layers and steel plates, and in the seocnd example the tehcnique is used to monitor progressive damage in wire rope.
Wu, Fei; Zhou, Zhaoyao; Duan, Liuyang; Xiao, Zhiyu
2015-01-01
A self-developed rotary multi-cutter device cuts stainless steel wire ropes into segments to fabricate twisted wires. Stainless steel porous twisted wire materials (PTWMs) with a spatial composite intertexture structure are produced by the compaction and subsequent vacuum solid-phase sintering of twisted wires. The stainless steel PTWMs show two types of typical uniaxial tensile failure modes, i.e., a 45° angle fracture mode and an auxetic failure mode (the PTWMs expand along the direction perpendicular to the tension). The effects of the sintering parameters, porosities, wire diameters, and sampling direction on the tensile properties of the PTWMs are carefully investigated. By increasing the sintering temperature from 1130 °C to 1330 °C, the tensile strength of the PTWMs with 70% target porosity increased from 7.7 MPa to 28.6 MPa and the total failure goes down to 50%. When increasing the sintering time from 90 min to 150 min, the tensile strength increases from 12.4 MPa to 19.1 MPa and the total failure elongation drops to 78.6%. The tensile strength of the PTWMs increases from 28.9 MPa to 112.7 MPa with decreasing porosity from 69.5% to 46.0%, and the total failure elongation also increases from 14.8% to 40.7%. The tensile strength and the failure strain of the PTWMs with fine wires are higher than those of the PTWMs with coarse wires under the same porosity. Sampling direction has a small influence on the tensile properties of the PTWMs. PMID:28793526
Wu, Fei; Zhou, Zhaoyao; Duan, Liuyang; Xiao, Zhiyu
2015-08-27
A self-developed rotary multi-cutter device cuts stainless steel wire ropes into segments to fabricate twisted wires. Stainless steel porous twisted wire materials (PTWMs) with a spatial composite intertexture structure are produced by the compaction and subsequent vacuum solid-phase sintering of twisted wires. The stainless steel PTWMs show two types of typical uniaxial tensile failure modes, i.e. , a 45° angle fracture mode and an auxetic failure mode (the PTWMs expand along the direction perpendicular to the tension). The effects of the sintering parameters, porosities, wire diameters, and sampling direction on the tensile properties of the PTWMs are carefully investigated. By increasing the sintering temperature from 1130 °C to 1330 °C, the tensile strength of the PTWMs with 70% target porosity increased from 7.7 MPa to 28.6 MPa and the total failure goes down to 50%. When increasing the sintering time from 90 min to 150 min, the tensile strength increases from 12.4 MPa to 19.1 MPa and the total failure elongation drops to 78.6%. The tensile strength of the PTWMs increases from 28.9 MPa to 112.7 MPa with decreasing porosity from 69.5% to 46.0%, and the total failure elongation also increases from 14.8% to 40.7%. The tensile strength and the failure strain of the PTWMs with fine wires are higher than those of the PTWMs with coarse wires under the same porosity. Sampling direction has a small influence on the tensile properties of the PTWMs.
Study on Elastic Helical TDR Sensing Cable for Distributed Deformation Detection
Tong, Renyuan; Li, Ming; Li, Qing
2012-01-01
In order to detect distributed ground surface deformation, an elastic helical structure Time Domain Reflectometry (TDR) sensing cable is shown in this paper. This special sensing cable consists of three parts: a silicone rubber rope in the center; a couple of parallel wires coiling around the rope; a silicone rubber pipe covering the sensing cable. By analyzing the relationship between the impedance and the structure of the sensing cable, the impedance model shows that the sensing cable impedance will increase when the cable is stretched. This specific characteristic is verified in the cable stretching experiment which is the base of TDR sensing technology. The TDR experiment shows that a positive reflected signal is created at the stretching deformation point on the sensing cable. The results show that the deformation section length and the stretching elongation will both affect the amplitude of the reflected signal. Finally, the deformation locating experiments show that the sensing cable can accurately detect the deformation point position on the sensing cable. PMID:23012560
Splicing Wires Permanently With Explosives
NASA Technical Reports Server (NTRS)
Bement, Laurence J.; Kushnick, Anne C.
1990-01-01
Explosive joining process developed to splice wires by enclosing and metallurgically bonding wires within copper sheets. Joints exhibit many desirable characteristics, 100-percent conductivity and strength, no heat-induced annealing, no susceptibility to corrosion in contacts between dissimilar metals, and stability at high temperature. Used to join wires to terminals, as well as to splice wires. Applicable to telecommunications industry, in which millions of small wires spliced annually.
NASA Technical Reports Server (NTRS)
1972-01-01
The practical use of small-gage round wire for electrical wiring in manned air and space vehicle environments is discussed. The investigation consisted on a study of wire construction and candidate wire harness concepts, fabrication of small-gage wire harnesses, and verification of promising configurations by laboratory evaluation. The wire constructions selected for harness fabrication are described. Results of the laboratory evaluation are included.
Brake wear warning device: A concept
NASA Technical Reports Server (NTRS)
Hawkins, S. F.
1973-01-01
Heat-insulated wire is introduced through brake shoe and partially into brake lining. Wire is connected to positive terminal and light bulb. When brakes wear to critical point, contact between wire and wheel drum grounds circuit and turns on warning light.
Experimental testing of flexible barriers for containment of debris flows
DeNatale, Jay S.; Iverson, Richard M.; Major, Jon J.; LaHusen, Richard G.; Fliegel, Gregg L.; Duffy, John D.
1999-01-01
In June 1996, six experiments conducted at the U.S. Geological Survey Debris Flow Flume demonstrated that flexible, vertical barriers constructed of wire rope netting can stop small debris flows. All experimental debris flows consisted of water-saturated gravelly sand with less than two percent finer sediment by weight. All debris flows had volumes of about 10 cubic meters, masses of about 20 metre tons, and impact velocities of 5 to 9 meters per second. In four experiments, the debris flow impacted pristine, unreformed barriers of varying design; in the other two experiments, the debris flow impacted barriers already loaded with sediment from a previous flow. Differences in barrier design led to differences in barrier performance. Experiments were conducted with barriers constructed of square-mesh wire-rope netting with 30centimeter, 20centimeter, and 15 centimeter mesh openings as well as 30centimeter diameter interlocking steel rings. In all cases, sediment cascading downslope at the leading edge of the debris flows tended to spray through the nets. Nets fitted with finer-mesh chain link or chicken wire liners contained more sediment than did unlined nets, and a ring net fitted with a synthetic silt screen liner contained nearly 100 percent of the sediment. Irreversible net displacements of up to 2 meters and friction brake engagement on the support and anchor cables dissipated some of the impact energy. However, substantial forces developed in the steel support columns and the lateral and tie-back anchor cables attached to these columns. As predicted by elementary mechanics, the anchor cables experienced larger tensile forces when the support columns were hinged at the base rather than bolted rigidly to the foundation. Measured loads in the lateral anchor cables exceeded those in the tie-back anchor cables and the load cell capacity of 45 kilo-Newtons. Measurements also indicated that the peak loads in the tie- back anchors were highly transient and occurred at the points of maximum momentum impulse to the net.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fan, Yuhong, E-mail: yfan@ucar.edu
2016-06-20
We carry out a 3D magnetohydrodynamic simulation to model the initiation of the coronal mass ejection (CME) on 2006 December 13 in the emerging δ -sunspot active region NOAA 10930. The setup of the simulation is similar to a previous simulation by Fan, but with a significantly widened simulation domain to accommodate the wide CME. The simulation shows that the CME can result from the emergence of a east–west oriented twisted flux rope whose positive, following emerging pole corresponds to the observed positive rotating sunspot emerging against the southern edge of the dominant pre-existing negative sunspot. The erupting flux ropemore » in the simulation accelerates to a terminal speed that exceeds 1500 km s{sup −1} and undergoes a counter-clockwise rotation of nearly 180° such that its front and flanks all exhibit southward directed magnetic fields, explaining the observed southward magnetic field in the magnetic cloud impacting the Earth. With continued driving of flux emergence, the source region coronal magnetic field also shows the reformation of a coronal flux rope underlying the flare current sheet of the erupting flux rope, ready for a second eruption. This may explain the build up for another X-class eruptive flare that occurred the following day from the same region.« less
47 CFR 36.152 - Categories of Cable and Wire Facilities (C&WF).
Code of Federal Regulations, 2014 CFR
2014-10-01
... 47 Telecommunication 2 2014-10-01 2014-10-01 false Categories of Cable and Wire Facilities (C&WF... Telecommunications Property Cable and Wire Facilities § 36.152 Categories of Cable and Wire Facilities (C&WF). (a) C... channels, and for circuits between control terminals and radio stations providing very high frequency...
47 CFR 36.152 - Categories of Cable and Wire Facilities (C&WF).
Code of Federal Regulations, 2013 CFR
2013-10-01
... 47 Telecommunication 2 2013-10-01 2013-10-01 false Categories of Cable and Wire Facilities (C&WF... Telecommunications Property Cable and Wire Facilities § 36.152 Categories of Cable and Wire Facilities (C&WF). (a) C... channels, and for circuits between control terminals and radio stations providing very high frequency...
47 CFR 36.152 - Categories of Cable and Wire Facilities (C&WF).
Code of Federal Regulations, 2012 CFR
2012-10-01
... 47 Telecommunication 2 2012-10-01 2012-10-01 false Categories of Cable and Wire Facilities (C&WF... Telecommunications Property Cable and Wire Facilities § 36.152 Categories of Cable and Wire Facilities (C&WF). (a) C... channels, and for circuits between control terminals and radio stations providing very high frequency...
46 CFR 28.865 - Wiring methods and materials.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 1 2010-10-01 2010-10-01 false Wiring methods and materials. 28.865 Section 28.865... FISHING INDUSTRY VESSELS Aleutian Trade Act Vessels § 28.865 Wiring methods and materials. (a) All cable... terminals is not more than 10 percent. (c) Cable and wiring not serving equipment in high risk fire areas...
Development and Evaluation of a Remedial Reading Workbook for Navy Training.
1979-12-01
quirements (1973) and the Bluejackets’ Manual, 20th Edition (1978). The workbook is based on established remedial reading principles and many of the exercises...knot is just a little over one mile an hour; or a knot in a rope; hitches and bends in a line LASH To tie up with a line (or wire). Le , inq is what you...long i. (Exercise 5 - silent vowel is circled) 1 - saior, 2 b* 3 - peoce, 4 - rescul 5 - ste_, 6 - fantag 7 - inbc&d, 8 - issu, 9 - le , 10 - rel e, 11
A Survey: The Principal Elements of Safety Programs of Nine Major American Shipyards
1991-01-01
Urine Breath Q 39. Subst. abuse Hearing Chest X-Ray Spirometry Q 40. Yes Q 41. Yes Q 42. Yes Q 43. Yes Q 44. Yes < Pipe Wire rope Chain Wood 8 YARD 1...Maintenance Safety Other 1. . 2. 3. 4. Q 71. Yes Q 72. Company Yard 14 Which of the following do you use as incentives to worker safety? (“1” is the...accident recording form? * * * * * * * * 8 This form is unique to your. . . * * * * * * 6 * * * * 4 Incentive programs and awareness programs
NASA Technical Reports Server (NTRS)
Dean, W. T.; Stringer, E. J.
1979-01-01
Crimp-type connectors reduce assembly and disassembly time. With design, no switch preparation is necessary and socket contracts are crimped to wires inserted in module attached to back of toggle switch engaging pins inside module to make electrical connections. Wires are easily removed with standard detachment tool. Design can accommodate wires of any gage and as many terminals can be placed on switch as wire gage and switch dimensions will allow.
NASA Astrophysics Data System (ADS)
Pal, Partha Pratim; Pati, Ranjit
2010-07-01
We report a first-principles study of quantum transport in a prototype two-terminal device consisting of a molecular nanowire acting as an inter-connect between two gold electrodes. The wire is composed of a series of bicyclo[1.1.1]pentane (BCP) cage-units. The length of the wire (L) is increased by sequentially increasing the number of BCP cage units in the wire from 1 to 3. A two terminal model device is made out of each of the three wires. A parameter free, nonequilibrium Green’s function approach, in which the bias effect is explicitly included within a many body framework, is used to calculate the current-voltage characteristics of each of the devices. In the low bias regime that is considered in our study, the molecular devices are found to exhibit Ohmic behavior with resistances of 0.12, 1.4, and 6.5μΩ for the wires containing one, two, and three cages respectively. Thus the conductance value, Gc , which is the reciprocal of resistance, decreases as e-βL with a decay constant (β) of 0.59Å-1 . This observed variation of conductance with the length of the wire is in excellent agreement with the earlier reported exponential decay feature of the electron transfer rate predicted from the electron transfer coupling matrix values obtained using the two-state Marcus-Hush model and the Koopman’s theorem approximation. The downright suppression of the computed electrical current for a bias up to 0.4 V in the longest wire can be exploited in designing a three terminal molecular transistor; this molecular wire could potentially be used as a throttle to avoid leakage gate current.
Code of Federal Regulations, 2014 CFR
2014-07-01
... beams or other house fall block supports shall be marked with the safe working load, which shall not be... depends upon components other than commonly used stock items such as shackles, ropes, or chains, and that... (c)(6) of this section). Single sheave blocks shall be marked with safe working loads and proof test...
Code of Federal Regulations, 2011 CFR
2011-07-01
... beams or other house fall block supports shall be marked with the safe working load, which shall not be... depends upon components other than commonly used stock items such as shackles, ropes, or chains, and that... (c)(6) of this section). Single sheave blocks shall be marked with safe working loads and proof test...
Code of Federal Regulations, 2010 CFR
2010-07-01
... beams or other house fall block supports shall be marked with the safe working load, which shall not be... depends upon components other than commonly used stock items such as shackles, ropes, or chains, and that... (c)(6) of this section). Single sheave blocks shall be marked with safe working loads and proof test...
Code of Federal Regulations, 2013 CFR
2013-07-01
... beams or other house fall block supports shall be marked with the safe working load, which shall not be... depends upon components other than commonly used stock items such as shackles, ropes, or chains, and that... (c)(6) of this section). Single sheave blocks shall be marked with safe working loads and proof test...
Code of Federal Regulations, 2012 CFR
2012-07-01
... beams or other house fall block supports shall be marked with the safe working load, which shall not be... depends upon components other than commonly used stock items such as shackles, ropes, or chains, and that... (c)(6) of this section). Single sheave blocks shall be marked with safe working loads and proof test...
Connecting to Thermocouples with Fewer Lead Wires
NASA Technical Reports Server (NTRS)
Goldsby, Jon C.
2003-01-01
A simple technique has been devised to reduce the number of lead wires needed to connect an array of thermocouples to the instruments (e.g., voltmeters) used to read their output voltages. Because thermocouple wires are usually made of expensive metal alloys, reducing the number of lead wires can effect a considerable reduction in the cost of such an array. Reducing the number of wires also reduces the number of terminals and the amount of space needed to accommodate the wires.
NASA Astrophysics Data System (ADS)
Ncube, Siphephile; Chimowa, George; Chiguvare, Zivayi; Bhattacharyya, Somnath
2014-07-01
The superiority of the electronic transport properties of single-walled carbon nanotube (SWNT) ropes over SWNT mats is verified from low temperature and frequency-dependent transport. The overall change of resistance versus in nanotube mats shows that 3D variable range hopping is the dominant conduction mechanism within the 2-300 K range. The magneto-resistance (MR) is found to be predominantly negative with a parabolic nature, which can also be described by the hopping model. Although the positive upturn of the MR at low temperatures establishes the contribution from quantum interference, the inherent quantum transport in individual tubes is suppressed at elevated temperatures. Therefore, to minimize multi-channel effects from inter-tube interactions and other defects, two-terminal devices were fabricated from aligned SWNT (extracted from a mat) for low temperature transport as well as high-frequency measurements. In contrast to the mat, the aligned ropes exhibit step-like features in the differential conductance within the 80-300 K temperature range. The effects of plasmon propagation, unique to one dimension, were identified in electronic transport as a non-universal power-law dependence of the differential conductance on temperature and source-drain voltage. The complex impedance showed high power transmission capabilities up to 65 GHz as well as oscillations in the frequency range up to 30 GHz. The measurements suggest that aligned SWNT ropes have a realistic potential for high-speed device applications.
Component for thermoelectric generator
Purdy, David L.
1977-01-01
In a thermoelectric generator, a component comprises a ceramic insulator, having over limited areas thereof, each area corresponding to a terminal end of thermoelectric wires, a coating of a first metal which adheres to the insulator, and an electrical thermoelectric junction including a second metal which wets said first metal and adheres to said terminal ends but does not wet said insulator, and a cloth composed of electrically insulating threads interlaced with thermoelectric wires.
ERIC Educational Resources Information Center
Kilmer, Donald C.
Designed for the student interested in a vocation in electrical work, this guide, fourth in a set of four, includes three units: Unit X--Splicing Wires, covering thirteen lessons (removing insulation, pigtail splice, Western Union splice, tap splice, extension cord splice, connecting wires to a terminal screw, underwriter's knot, three-wire ground…
NASA Technical Reports Server (NTRS)
Bashin, S.; Kelley, F. G.
1977-01-01
Terminal, which replaces stakes or lugs in conventional design with loop receptacles for wires from cell and harness, uses dissimilar bonding properties (metal-to-glass and/or ceramics) of iron-nickel-cobalt alloy in conjunction with standard termination.
2007-02-01
SUNWAVE as a viable alternative to organotin, copper , and other more toxic coatings. The Table III.D.3 below shows methods used for coating the buoy hull...trasdu 1.8 m (2 each) Tsunameter S almm chain (3.5 m) Swivel ss , u-d ct, of-aoic 25 mm nylon G.l as ball acoustic flotation teiemetry 1 22 mm nylon...e - Size(s) Manufacturer .... .......... Chain ,Wire Rope- Hardware Flotation Type (G.8.s, Spheres,_etc) Si ze Quantijty Color No. of Flotation
NASA Astrophysics Data System (ADS)
Wnęk, M.; Górzny, M. Ł.; Ward, M. B.; Wälti, C.; Davies, A. G.; Brydson, R.; Evans, S. D.; Stockley, P. G.
2013-01-01
The rod-shaped plant virus tobacco mosaic virus (TMV) is widely used as a nano-fabrication template, and chimeric peptide expression on its major coat protein has extended its potential applications. Here we describe a simple bacterial expression system for production and rapid purification of recombinant chimeric TMV coat protein carrying C-terminal peptide tags. These proteins do not bind TMV RNA or form disks at pH 7. However, they retain the ability to self-assemble into virus-like arrays at acidic pH. C-terminal peptide tags in such arrays are exposed on the protein surface, allowing interaction with target species. We have utilized a C-terminal His-tag to create virus coat protein-templated nano-rods able to bind gold nanoparticles uniformly. These can be transformed into gold nano-wires by deposition of additional gold atoms from solution, followed by thermal annealing. The resistivity of a typical annealed wire created by this approach is significantly less than values reported for other nano-wires made using different bio-templates. This expression construct is therefore a useful additional tool for the creation of chimeric TMV-like nano-rods for bio-templating.
Universal behavior of surface-dangling bonds in hydrogen-terminated Si, Ge, and Si/Ge nanowires.
NASA Astrophysics Data System (ADS)
Nunes, Ricardo; Kagimura, Ricardo; Chacham, Hélio
2007-03-01
We report an ab initio study of the electronic properties of surface dangling bond (SDB) states in hydrogen-terminated Si, Ge, and Si/Ge nanowires with diameters between 1 and 2 nm. We find that the charge transition levels ɛ(+/-) of SDB states are deep in the bandgap for Si wires, and shallow (near the valence band edge) for Ge wires. In both Si and Ge wires, the SDB states are localized. We also find that the SDB ɛ(+/-) levels behave as a ``universal" energy reference level among Si, Ge, and Si/Ge wires within a precision of 0.1 eV. By computing the average bewteen the electron affinity and ionization energy in the atomi limit of several atoms from the III, IV and V columns, we conjecture that the universality is a periodic-table atomic property.
KIM-1 interface adapter to 3-wire teletype systems
NASA Technical Reports Server (NTRS)
Burhans, R. W.
1976-01-01
The KIM-1 circuit designed for use with a full duplex isolated 4 terminal system is described. Operation of the circuit with a 3 wire system in conjunction with a single +5v supply interface is discussed.
Metering Wheel-Wire Track Wire Boom Deployment Mechanism
NASA Technical Reports Server (NTRS)
Granoff, Mark S.
2014-01-01
The NASA MMS Spin Plane Double Probe (SDP) Deployer utilizes a helical path, rotating Metering Wheel and a spring loaded Wire "Holding" Track to pay out a "fixed end" 57 meter x 1.5 mm diameter Wire Boom stored between concentric storage cylinders. Unlike rotating spool type storage devices, the storage cylinders remain stationary, and the boom wire is uncoiled along the length of the cylinder via the rotation of the Metering Wheel. This uncoiling action avoids the need for slip-ring contacts since the ends of the wire can remain stationary. Conventional fixed electrical connectors (Micro-D type) are used to terminate to operational electronics.
Chen, Xiaodong; Jeon, You-Moon; Jang, Jae-Won; Qin, Lidong; Huo, Fengwei; Wei, Wei; Mirkin, Chad A
2008-07-02
On-wire lithography (OWL) fabricated nanogaps are used as a new testbed to construct molecular transport junctions (MTJs) through the assembly of thiolated molecular wires across a nanogap formed between two Au electrodes. In addition, we show that one can use OWL to rapidly characterize a MTJ and optimize gap size for two molecular wires of different dimensions. Finally, we have used this new testbed to identify unusual temperature-dependent transport mechanisms for alpha,omega-dithiol terminated oligo(phenylene ethynylene).
Apparatus for disintegrating kidney stones
NASA Technical Reports Server (NTRS)
Angulo, E. D. (Inventor)
1984-01-01
The useful life of the wire probe in an ultrasonic kidney stone disintegration instrument is enhanced and prolonged by attaching the wire of the wire probe to the tip of an ultrasonic transducer by means of a clamping arrangement. Additionally, damping material is applied to the wire probe in the form of a damper tube through which the wire probe passes in the region adjacent the transducer tip. The damper tube extends outwardly from the transducer tip a predetermined distance, terminating in a resilient soft rubber joint. Also, the damper tube is supported intermediate its length by a support member. The damper system thus acts to inhibit lateral vibrations of the wire in the region of the transducer tip while providing little or no damping to the linear vibrations imparted to the wire by the transducer.
The impact of debris on the Florida manatee
Beck, C.A.; Barros, N.B.
1991-01-01
The endangered Florida manatee ingests debris while feeding. From 1978 through 1986, 439 salvaged manatees were examined. Debris was in the gastrointestinal tract of 63 (14.4%) and four died as a direct result of debris ingestion. Monofilament fishing line was the most common debris found (N=49). Plastic bags, string, twine, rope, fish hooks, wire, paper, cellophane, synthetic sponges, rubber bands, and stockings also were recovered. Entanglement in lines and nets killed 11 manatees from 1974 through 1985. Numerous free-ranging manatees have missing or scarred flippers from entanglements, or debris still encircling one or both flippers. We recommend local cleanups, education of the public, and fishing restrictions in high use areas to significantly reduce harm to manatees.
Fuzzy crane control with sensorless payload deflection feedback for vibration reduction
NASA Astrophysics Data System (ADS)
Smoczek, Jaroslaw
2014-05-01
Different types of cranes are widely used for shifting cargoes in building sites, shipping yards, container terminals and many manufacturing segments where the problem of fast and precise transferring a payload suspended on the ropes with oscillations reduction is frequently important to enhance the productivity, efficiency and safety. The paper presents the fuzzy logic-based robust feedback anti-sway control system which can be applicable either with or without a sensor of sway angle of a payload. The discrete-time control approach is based on the fuzzy interpolation of the controllers and crane dynamic model's parameters with respect to the varying rope length and mass of a payload. The iterative procedure combining a pole placement method and interval analysis of closed-loop characteristic polynomial coefficients is proposed to design the robust control scheme. The sensorless anti-sway control application developed with using PAC system with RX3i controller was verified on the laboratory scaled overhead crane.
The main beam efficiency of corner cube reflectors
NASA Astrophysics Data System (ADS)
Vowinkel, B.
1986-01-01
A computer model for the calculation of the beam pattern and the main beam efficiency of corner cube reflectors used in submillimeter heterodyne systems is described. The model includes possible mismatches at the termination of the wire antenna, the attenuation of the wave along the wire due to emission and the contribution of the wire bend to the antenna pattern. Measurements with a scale model at 15 GHz show good agreement between experiment and theory.
Marine biomass: New York State species and site studies. Annual report December 1982-November 1983
DOE Office of Scientific and Technical Information (OSTI.GOV)
McKay, L.B.
1983-11-01
The Energy Authority has been conducting tests since 1979 in an effort to develop a feasible system for the production in Long Island Sound of marine biomass from indigenous macroalgae for economically competitive conversion to synthetic natural gas. During 1983 this goal was brought closer to realization when a 120 x 41 foot seaweed test farm was placed in 60 feet of water in Long Island Sound. The structure is basically a flexible wire cable and rope grid, buoyed at the surface and moored to the bottom of the Sound. It is suitable for cultivating seaweeds that attach themselves tomore » surfaces such as the brown kelp, Laminaria saccharina. The test farm design was chosen from among four previously developed by the engineering team. An ongoing program is taking place in Long Island Sound to test the strength of the structure and to obtain information on plants growing in the structure. The program will test the strain on the lines, corrosion on metal parts, and available light and temperature at various times. Also, since 1982, bioengineering tests have focused on biofouling experiments, and seaweed and rope strength tests. The report also includes discussion of a laboratory research program focused on seeding techniques and strain selection.« less
A Method For The Verification Of Wire Crimp Compression Using Ultrasonic Inspection
NASA Technical Reports Server (NTRS)
Cramer, K. E.; Perey, Daniel F.; Yost, William t.
2010-01-01
The development of a new ultrasonic measurement technique to assess quantitatively wire crimp terminations is discussed. The amplitude change of a compressional ultrasonic wave propagating at right angles to the wire axis and through the junction of a crimp termination is shown to correlate with the results of a destructive pull test, which is a standard for assessing crimp wire junction quality. To demonstrate the technique, the case of incomplete compression of crimped connections is ultrasonically tested, and the results are correlated with pull tests. Results show that the nondestructive ultrasonic measurement technique consistently predicts good crimps when the ultrasonic transmission is above a certain threshold amplitude level. A quantitative measure of the quality of the crimped connection based on the ultrasonic energy transmitted is shown to respond accurately to crimp quality. A wave propagation model, solved by finite element analysis, describes the compressional ultrasonic wave propagation through the junction during the crimping process. This model is in agreement within 6% of the ultrasonic measurements. A prototype instrument for applying this technique while wire crimps are installed is also presented. The instrument is based on a two-jaw type crimp tool suitable for butt-splice type connections. A comparison of the results of two different instruments is presented and shows reproducibility between instruments within a 95% confidence bound.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 3 2010-10-01 2010-10-01 false Definitions. 69.703 Section 69.703... Pricing Flexibility § 69.703 Definitions. For purposes of this subpart: (a) Channel terminations. (1) A channel termination between an IXC POP and a serving wire center is a dedicated channel connecting an IXC...
University Engineering Design Challenge
2015-01-29
solution was to design a sort of friction winch which would use friction to grip the rope sufficiently to wind itself up the rope without slipping ...provide enough friction to wind itself up the rope. It was determined through analysis that the friction pulley method would be the better solution...squeezed the rope becomes in the groove. This provides the friction which allows the rope not to slip in the pulley as it climbs the rope. The Metric
Energetic particle characteristics of magnetotail flux ropes
NASA Technical Reports Server (NTRS)
Scholer, M.; Klecker, B.; Hovestadt, D.; Gloeckler, G.; Ipavich, F. M.; Galvin, A. B.
1985-01-01
During the recent ISEE-3 Geotail Mission three events have been identified from the magnetometer data which are consistent with a spacecraft crossing of a magnetotail flux rope. Energetic electron and proton observations obtained by the Max-Planck-Institut/University of Maryland sensor system during two of the possible flux rope events are presented. During one event remote sensing of the flux rope with energetic protons reveals that the flux rope is crossed by the spacecraft from south to north. This allows determination of the bandedness of the magnetic field twist and of the flux rope velocity relative to the spacecraft. A minimal flux rope radius of 3 earth radii is derived. Energetic proton intensity is highest just inside of the flux rope and decreases towards the core. Energetic electrons are streaming tailward near the outer boundary, indicating openness of the field lines, and are isotropic through the inner part of the flux rope.
NASA Technical Reports Server (NTRS)
Wei, C. Q.; Lee, L. C.; Wang, S.; Akasofu, S.-I.
1991-01-01
Spacecraft observations suggest that flux transfer events and interplanetary magnetic clouds may be associated with magnetic flux ropes which are magnetic flux tubes containing helical magnetic field lines. In the magnetic flux ropes, the azimuthal magnetic field is superposed on the axial field. The time evolution of a localized magnetic flux rope is studied. A two-dimensional compressible MHD simulation code with a cylindrical symmetry is developed to study the wave modes associated with the evolution of flux ropes. It is found that in the initial phase both the fast magnetosonic wave and the Alfven wave are developed in the flux rope. After this initial phase, the Alfven wave becomes the dominant wave mode for the evolution of the magnetic flux rope and the radial expansion velocity of the flux rope is found to be negligible. Numerical results further show that even for a large initial azimuthal component of the magnetic field, the propagation velocity along the axial direction of the flux rope remains the Alfven velocity. It is also found that the localized magnetic flux rope tends to evolve into two separate magnetic ropes propagating in opposite directions. The simulation results are used to study the evolution of magnetic flux ropes associated with flux transfer events observed at the earth's dayside magnetopause and magnetic clouds in the interplanetary space.
Performance Enhancement of the Space Shuttle RSRM Nozzle-to-Case Joint Using a Carbon Rope Barrier
NASA Technical Reports Server (NTRS)
Ewing, M. E.; McGuire, J. R.; McWhorter, B. B.; Frost, D. L.
1999-01-01
A carbon rope "thermal barrier" is being considered as a component to enhance performance of the Reusable Solid Rocket Motor (RSRM) nozzle-to-case joint. Fundamental performance characteristics of the rope have been considered in this paper. In particular, resistance to erosion, ability to filter particulate matter, thermal capacitance, and flow resistance have been considered. Testing results have shown the rope to be resistant to the corrosive internal environment of the RSRM. The rope has also been shown to be an effective "slag barrier." A desirable feature of the rope would be the ability to act as a heat sink. However, analyses have indicated that the thermal capacitance of the rope is not large enough to reduce the temperature of an impinging gas stream below the ablation temperature of the 0-ring for significant time periods, The real value of the rope is its ability to act as a flow diffuser. Flow resistance test, were performed on the rope In the course of testing the rope between parallel plates, an undesirable "blow-by" phenomenon was observed when the compressive stress in the rope was smaller than the upstream gas pressure. It was found, however, that in the converging passage of the actual design, the rope would consistently "Self-seat" and thereby prevent blow-by, even in the absence of any precompression. Flow resistance values have been quantified for use in future analyses. The work presented here provides an initial thermal-fluid assessment of the rope for this application, and lays the groundwork for future development.
Are There Different Populations of Flux Ropes in the Solar Wind?
NASA Astrophysics Data System (ADS)
Janvier, M.; Démoulin, P.; Dasso, S.
2014-07-01
Flux ropes are twisted magnetic structures that can be detected by in-situ measurements in the solar wind. However, different properties of detected flux ropes suggest different types of flux-rope populations. As such, are there different populations of flux ropes? The answer is positive and is the result of the analysis of four lists of flux ropes, including magnetic clouds (MCs), observed at 1 AU. The in-situ data for the four lists were fitted with the same cylindrical force-free field model, which provides an estimate of the local flux-rope parameters such as its radius and orientation. Since the flux-rope distributions have a broad dynamic range, we went beyond a simple histogram analysis by developing a partition technique that uniformly distributes the statistical fluctuations across the radius range. By doing so, we found that small flux ropes with radius R<0.1 AU have a steep power-law distribution in contrast to the larger flux ropes (identified as MCs), which have a Gaussian-like distribution. Next, from four CME catalogs, we estimated the expected flux-rope frequency per year at 1 AU. We found that the predicted numbers are similar to the frequencies of MCs observed in-situ. However, we also found that small flux ropes are at least ten times too abundant to correspond to CMEs, even to narrow ones. Investigating the different possible scenarios for the origin of these small flux ropes, we conclude that these twisted structures can be formed by blowout jets in the low corona or in coronal streamers.
NASA Astrophysics Data System (ADS)
le Roux, J. A.
2017-12-01
We developed previously a focused transport kinetic theory formalism with Fokker-plank coefficients (and its Parker transport limit) to model large-scale energetic particle transport and acceleration in solar wind regions with multiple contracting and merging small-scale flux ropes on MHD (inertial) scales (Zank et al. 2014; le Roux et al. 2015). The theory unifies the main acceleration mechanisms identified in particle simulations for particles temporarily trapped in such active flux rope structures, such as acceleration by the parallel electric field in reconnection regions between merging flux ropes, curvature drift acceleration in incompressible/compressible contracting and merging flux ropes, and betatron acceleration (e.g., Dahlin et al 2016). Initial analytical solutions of the Parker transport equation in the test particle limit showed that the energetic particle pressure from efficient flux-rope energization can potentially be high in turbulent solar wind regions containing active flux-rope structures. This requires taking into account the back reaction of energetic particles on flux ropes to more accurately determine the efficiency of energetic particles acceleration by small-scale flux ropes. To accomplish this goal we developed recently an extension of the kinetic theory to a kinetic-MHD level. We will present the extended theory showing the focused transport equation to be coupled to a solar wind MHD transport equation for small-scale flux-rope energy density extracted from a recently published nearly incompressible theory for solar wind MHD turbulence with a plasma beta of 1 (Zank et al. 2017). In the flux-rope transport equation appears new expressions for the damping/growth rates of flux-rope energy derived from assuming energy conservation in the interaction between energetic particles and small-scale flux ropes for all the main flux-rope acceleration mechanisms, whereas previous expressions for average particle acceleration rates have been explored in more detail. Future applications will involve exploring the relative role of diffusive shock and flux-ropes acceleration in the vicinity of traveling shocks in the supersonic solar wind near Earth where many flux-rope structures were detected recently (Hu et al 2017, this session).
30 CFR 56.19021 - Minimum rope strength.
Code of Federal Regulations, 2010 CFR
2010-07-01
...=Static Load×4.0 (b) Friction drum ropes. For rope lengths less than 4,000 feet: Minimum Value=Static Load×(7.0-0.0005L) For rope lengths 4,000 feet or greater: Minimum Value=Static Load×5.0 (c) Tail ropes....19021 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL...
30 CFR 56.19021 - Minimum rope strength.
Code of Federal Regulations, 2011 CFR
2011-07-01
...=Static Load×4.0 (b) Friction drum ropes. For rope lengths less than 4,000 feet: Minimum Value=Static Load×(7.0-0.0005L) For rope lengths 4,000 feet or greater: Minimum Value=Static Load×5.0 (c) Tail ropes....19021 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL...
30 CFR 75.1431 - Minimum rope strength.
Code of Federal Regulations, 2011 CFR
2011-07-01
...) For rope lengths 3,000 feet or greater: Minimum Value=Static Load×4.0 (b) Friction drum ropes. For rope lengths less than 4,000 feet: Minimum Value=Static Load×(7.0−0.0005L) For rope lengths 4,000 feet... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH...
30 CFR 75.1431 - Minimum rope strength.
Code of Federal Regulations, 2010 CFR
2010-07-01
...) For rope lengths 3,000 feet or greater: Minimum Value=Static Load×4.0 (b) Friction drum ropes. For rope lengths less than 4,000 feet: Minimum Value=Static Load×(7.0−0.0005L) For rope lengths 4,000 feet... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH...
Evidence for helical kink instability in the Venus magnetic flux ropes
NASA Technical Reports Server (NTRS)
Elphic, R. C.; Russell, C. T.
1983-01-01
Empirical models of the magnetic field structure of flux ropes found in the Venus ionosphere are seen as suggesting that the ropes are unstable to long-wavelength (more than 100 km) helical-kink perturbations. The onset of such an instability can explain the apparent volume distribution of flux ropes with altitude, as well as their orientation as a function of altitude. In the subsolar region, the fraction of volume occupied by flux ropes increases from approximately 20 percent at high altitudes to more than 50 percent at low altitudes; this is a greater increase than would be expected if ropes convect downward as simple straight horizontal cylinders. The helical kink instability raises the fractional volume occupied by ropes by turning the originally straight, horizontal flux tubes into corkscrew-shaped structures as they convect to lower altitudes. It is noted that this instability also explains why high altitude ropes tend to be horizontal and low altitude ropes appear to have almost any orientation.
Code of Federal Regulations, 2010 CFR
2010-10-01
... responsible supervision and control of a person who: (1) Has had at least six months of on-the-job experience... grandfathered equipment is involved) of the first piece of equipment electrically connected to the telephone... six months of on-the-job experience in the installation of telephone terminal equipment or of wiring...
Interactive wire-frame ship hullform generation and display
NASA Technical Reports Server (NTRS)
Calkins, D. E.; Garbini, J. L.; Ishimaru, J.
1984-01-01
An interactive automated procedure to generate a wire frame graphic image of a ship hullform, which uses a digitizing tablet in conjunction with the hullform lines drawing, was developed. The geometric image created is displayed on an Evans & Sutherland PS-300 graphics terminal for real time interactive viewing or is output as hard copy on an inexpensive dot matrix printer.
CJ concept for advanced aircraft wiring
NASA Technical Reports Server (NTRS)
Redslob, J.
1972-01-01
The techniques and hardware are described which were developed for facilitating the use of flexible flat conductor cable (FFCC) in commercial air transports. The system was designed as an evolutionary transition from the current round wire harnessing to the use of FFCC harnesses. The equipment discussed includes the pressure crimp barrel designed for terminating FFCC, reel-fed applicator, cable connectors and adaptors, and equipment racks.
NASA Technical Reports Server (NTRS)
1972-01-01
A cost study comparing flat conductor cable (FCC) with small-gage wire (SGW) and conventional round conductor cable (RCC) is presented. This study was based on a vehicle wiring system consisting of 110,000 ft of conventional RCC equally divided between AWG sizes 20,22, and 24 using MIL-W-81044-type wire and MIL-C-26500 circular connectors. Basic cost data were developed on a similar-sized commercial jet airplane wiring system on a previous company R&D program in which advanced wiring techniques were carried through equivalent installations on an airplane mockup; and on data developed on typical average bundles during this program. Various cost elements included were engineering labor, operations (manufacturing) labor, material costs, and cost impact on payload. Engineering labor includes design, wiring system integration, wiring diagrams and cable assembly drawings, wire installations, and other related supporting functions such as the electronic data processing for the wiring. Operations labor includes mockup, tooling and production planning, fabrication, assembly, installation, and quality control cost impact on payload is the conversion of wiring system weight variations through use of different wiring concepts to program payload benefits in terms of dollars.
30 CFR 77.1431 - Minimum rope strength.
Code of Federal Regulations, 2011 CFR
2011-07-01
...=Static Load×4.0 (b) Friction drum ropes. For rope lengths less than 4,000 feet: Minimum Value=Static Load×(7.0−0.0005L) For rope lengths 4,000 feet or greater: Minimum Value=Static Load×5.0 (c) Tail ropes... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH...
30 CFR 77.1431 - Minimum rope strength.
Code of Federal Regulations, 2010 CFR
2010-07-01
...=Static Load×4.0 (b) Friction drum ropes. For rope lengths less than 4,000 feet: Minimum Value=Static Load×(7.0−0.0005L) For rope lengths 4,000 feet or greater: Minimum Value=Static Load×5.0 (c) Tail ropes... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH...
On the formation of tilted flux ropes in the Earth's magnetotail observed with ARTEMIS
NASA Astrophysics Data System (ADS)
Kiehas, S. A.; Angelopoulos, V.; Runov, A.; Moldwin, M. B.; Möstl, C.
2012-05-01
On 21 October 2010, ARTEMIS spacecraft P2, located at about -57 REGSM in the Earth's magnetotail, observed a series of flux ropes during the course of a moderate substorm. Subsequently, ARTEMIS spacecraft P1, located about 20 RE farther downtail and farther into the lobe than P2, observed a series of TCRs, consistent with the flux ropes observed by P2. The dual-spacecraft configuration allows simultaneous examination of these phenomena, which are interpreted as an O-line, followed by a series of flux ropes/TCRs. An inter-spacecraft time of flight analysis, assuming tailward propagation of cross-tail aligned ropes, suggests propagation speeds of up to ˜2000 km/s. A principal axis investigation, however, indicates that the flux ropes were tilted between 41° and 45° in the GSM x-y-plane with respect to the noon-midnight meridional plane. Taking this into account, the tailward propagation speed of the different flux ropes is determined to be between 900 and 1400 km/s. The same timing analysis also reveals that the flux rope velocity increased progressively from one flux rope to the next. A clear correlation between the magnetic field and plasma flow components inside the flux ropes was observed. As possible mechanisms leading to the formation of tilted flux ropes we suggest (a) a progressive spreading of the reconnection line along the east-west direction, leading to a boomerang-like shape and (b) a tilting of flux ropes during their formation by non-uniform reconnection with open field lines at the ends of the flux ropes. The progressive increase in the propagation velocity from the first to the last flux rope may be evidence of impulsive reconnection: initially deep inside the plasma sheet the reconnection rate is slow but as reconnection proceeds at the plasma sheet boundary and possibly lobes, the reconnection rate increases.
Design of power cable grounding wire anti-theft monitoring system
NASA Astrophysics Data System (ADS)
An, Xisheng; Lu, Peng; Wei, Niansheng; Hong, Gang
2018-01-01
In order to prevent the serious consequences of the power grid failure caused by the power cable grounding wire theft, this paper presents a GPRS based power cable grounding wire anti-theft monitoring device system, which includes a camera module, a sensor module, a micro processing system module, and a data monitoring center module, a mobile terminal module. Our design utilize two kinds of methods for detecting and reporting comprehensive image, it can effectively solve the problem of power and cable grounding wire box theft problem, timely follow-up grounded cable theft events, prevent the occurrence of electric field of high voltage transmission line fault, improve the reliability of the safe operation of power grid.
IET. Control room in control building (TAN620). Terminal panels for ...
IET. Control room in control building (TAN-620). Terminal panels for instrumentation wiring. Note alarm horn and emergency light at right edge of view. Cable reel comes from Collier, Pawtucket, RI. Date: February 1955. INEEL negative no. 55-362 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
Measurements of the Canonical Helicity Evolution of a Gyrating Kinked Flux Rope
NASA Astrophysics Data System (ADS)
von der Linden, J.; Sears, J.; Intrator, T.; You, S.
2017-12-01
Magnetic structures in the solar corona and planetary magnetospheres are often modelled as magnetic flux ropes governed by magnetohydrodynamics (MHD); however, inside these structures, as exhibited in reconnection, conversions between magnetic and kinetic energies occur over a wide range of scales. Flux ropes based on the flux of canonical momentum circulation extend the flux rope concept to include effects of finite particle momentum and present the distinct advantage of reconciling all plasma regimes - e.g. kinetic, two-fluid, and MHD - with the topological concept of helicity: twists, writhes, and linkages. This presentation shows the first visualization and analysis of the 3D dynamics of canonical flux ropes and their relative helicity evolution from laboratory measurements. Ion and electron canonical flux ropes are visualized from a dataset of Mach, triple, and Ḃ probe measurements at over 10,000 spatial locations of a gyrating kinked flux rope. The flux ropes co-gyrate with the peak density and electron temperature in and out of a measurement volume. The electron and ion canonical flux ropes twist with opposite handedness and the ion flux ropes writhe around the electron flux ropes. The relative cross helicity between the magnetic and ion flow vorticity flux ropes dominates the relative ion canonical helicity and is anti-correlated with the relative magnetic helicity. The 3D nature of the kink and a reverse eddy current affect the helicity evolution. This work is supported by DOE Grant DE-SC0010340 and the DOE Office of Science Graduate Student Research Program and prepared in part by LLNL under Contract DE-AC52-07NA27344. LLNL-ABS-735426
Genesis of Interplanetary Intermittent Turbulence: a Case Study of Rope-Rope Magnetic Reconnection
NASA Technical Reports Server (NTRS)
Chian, Abraham C.- L.; Feng, Heng Q.; Hu, Qiang; Loew, Murray H.; Miranda, Rodrigo A.; Munoz, Pablo R.; Sibeck, David G.; Wu, De J.
2016-01-01
In a recent paper, the relation between current sheet, magnetic reconnection, and turbulence at the leading edge of an interplanetary coronal mass ejection was studied. We report here the observation of magnetic reconnection at the interface region of two interplanetary magnetic flux ropes. The front and rear boundary layers of three interplanetary magnetic flux ropes are identified, and the structures of magnetic flux ropes are reconstructed by the Grad Shafranov method. A quantitative analysis of the reconnection condition and the degree of intermittency reveals that rope-rope magnetic reconnection is the most likely site for genesis of interplanetary intermittency turbulence in this event. The dynamic pressure pulse resulting from this reconnection triggers the onset of a geomagnetic storm.
Numerical Experiments Based on the Catastrophe Model of Solar Eruptions
NASA Astrophysics Data System (ADS)
Xie, X. Y.; Ziegler, U.; Mei, Z. X.; Wu, N.; Lin, J.
2017-11-01
On the basis of the catastrophe model developed by Isenberg et al., we use the NIRVANA code to perform the magnetohydrodynamics (MHD) numerical experiments to look into various behaviors of the coronal magnetic configuration that includes a current-carrying flux rope used to model the prominence levitating in the corona. These behaviors include the evolution in equilibrium heights of the flux rope versus the change in the background magnetic field, the corresponding internal equilibrium of the flux rope, dynamic properties of the flux rope after the system loses equilibrium, as well as the impact of the referential radius on the equilibrium heights of the flux rope. In our calculations, an empirical model of the coronal density distribution given by Sittler & Guhathakurta is used, and the physical diffusion is included. Our experiments show that the deviation of simulations in the equilibrium heights from the theoretical results exists, but is not apparent, and the evolutionary features of the two results are similar. If the flux rope is initially locate at the stable branch of the theoretical equilibrium curve, the flux rope will quickly reach the equilibrium position in the simulation after several rounds of oscillations as a result of the self-adjustment of the system; and the flux rope lose the equilibrium if the initial location of the flux rope is set at the critical point on the theoretical equilibrium curve. Correspondingly, the internal equilibrium of the flux rope can be reached as well, and the deviation from the theoretical results is somewhat apparent since the approximation of the small radius of the flux rope is lifted in our experiments, but such deviation does not affect the global equilibrium in the system. The impact of the referential radius on the equilibrium heights of the flux rope is consistent with the prediction of the theory. Our calculations indicate that the motion of the flux rope after the loss of equilibrium is consistent with which is predicted by the Lin-Forbes model and observations. Formation of the fast mode shock ahead of the flux rope is observed in our experiments. Outward motions of the flux rope are smooth, and magnetic energy is continuously converted into the other types of energy because both the diffusions are considered in calculations, and magnetic reconnection is allowed to occur successively in the current sheet behind the flux rope.
NASA Astrophysics Data System (ADS)
Kaloko, Bambang Sri; Atsari, Erinna Dyah
2017-03-01
Electric motive force which flows into the iron core continuously on a plate - plate iron isolated may cause heat posed by current eddy (eddy current). No water loss occurs due to detainees on the circuit at the the flow of current load because this loss happened on the entanglement of the transformer is made of copper. Continuously Transposed Conductors (CTC) consist of a number of enameled rectangular wires (5-84 strands) made into an assembly. Each strand is transposed in turn to each position in the cable and is then covered with layers of insulation paper. Continuously Transposed Conductors are used in winding wires for medium and ultra high power transformers. CTC is manufactured by OFHC copper and indeed, is able to supply polyester roped. CTC which has been designed to reduce production cost, oil pocket and improve cooling efficiency. Hardened type CTC (CPR1, CPR2, and CPR3: BS1432) and Self-bonding CTC which can be used to improve mechanical and electrical strength are also available. This analysis is performed using the methods of fuzzy logic in taking account of the resources.
Self-organization in magnetic flux ropes
NASA Astrophysics Data System (ADS)
Lukin, Vyacheslav S.
2014-06-01
This cross-disciplinary special issue on 'Self-organization in magnetic flux ropes' follows in the footsteps of another collection of manuscripts dedicated to the subject of magnetic flux ropes, a volume on 'Physics of magnetic flux ropes' published in the American Geophysical Union's Geophysical Monograph Series in 1990 [1]. Twenty-four years later, this special issue, composed of invited original contributions highlighting ongoing research on the physics of magnetic flux ropes in astrophysical, space and laboratory plasmas, can be considered an update on our state of understanding of this fundamental constituent of any magnetized plasma. Furthermore, by inviting contributions from research groups focused on the study of the origins and properties of magnetic flux ropes in a variety of different environments, we have attempted to underline both the diversity of and the commonalities among magnetic flux ropes throughout the solar system and, indeed, the universe. So, what is a magnetic flux rope? The answer will undoubtedly depend on whom you ask. A flux rope can be as narrow as a few Larmor radii and as wide as the Sun (see, e.g., the contributions by Heli Hietala et al and by Angelous Vourlidas). As described below by Ward Manchester IV et al , they can stretch from the Sun to the Earth in the form of interplanetary coronal mass ejections. Or, as in the Swarthmore Spheromak Experiment described by David Schaffner et al , they can fit into a meter-long laboratory device tended by college students. They can be helical and line-tied (see, e.g., Walter Gekelman et al or J Sears et al ), or toroidal and periodic (see, e.g., John O'Bryan et al or Philippa Browning et al ). They can form in the low plasma beta environment of the solar corona (Tibor Török et al ), the order unity beta plasmas of the solar wind (Stefan Eriksson et al ) and the plasma pressure dominated stellar convection zones (Nicholas Nelson and Mark Miesch). In this special issue, Setthivoine You describes how canonical helicity can determine the result of reconnection and merging of multiple magnetic flux ropes, John Finn et al focus on diagnosing flux rope reconnection using quasi-separatrix layers, and Stefano Markidis et al investigate how a single flux rope can become unstable and begin to fall apart. With these many examples of different magnetized plasma structures, which can all be called magnetic flux ropes, the question still stands: just what is it that makes a volume of magnetized plasma a magnetic flux rope? There may not be a strict definition of a magnetic flux rope that everyone can agree on. Nonetheless, the ingredient common to all magnetic flux ropes is that the magnetic field lines that thread nearby plasma elements at one location along the flux rope must wind around and not diverge away from each other over a sufficiently long distance to look like a piece of an ordinary rope. In a way, it is similar to turbulence—you know it when you see it. The figures and illustrations included in this special issue provide plenty of examples of observed, measured, modeled and imagined magnetic flux ropes for you, the reader, to develop an appreciation of what different members of our research community mean by a magnetic flux rope. If you have never studied magnetic flux ropes, we hope that this special issue inspires you to look into their many mysteries. If magnetic flux ropes are already an integral part of your research, we hope the diversity of perspectives presented herein refresh your interest in the underlying plasma physics of whichever kind of magnetic flux rope you happen to be working with. References [1] Russell C T, Priest E R and Lee L-C 1990 Physics of Magnetic Flux Ropes AGU Geophysical Monograph Series vol 58 (Washington, DC: American Geophysical Union)
1975-04-01
seawater. The principal effect of crevices on the corrosion of zinc- or aluminum - coated or uncoated steel rope is to entrap corrosive liquids and...visual inspection of the rope surface. j 5. The effect of stresses, such as tensile, bending, torsion , and comn- pression, upon rope in service is not...questionable A value. d. The effect of stresses, such as tensile, bending, torsion , and compressive contact, on rope is not understood well. 2
NASA Astrophysics Data System (ADS)
Tuan, Le Anh; Lee, Soon-Geul
2018-03-01
In this study, a new mathematical model of crawler cranes is developed for heavy working conditions, with payload-lifting and boom-hoisting motions simultaneously activated. The system model is built with full consideration of wind disturbances, geometrical nonlinearities, and cable elasticities of cargo lifting and boom luffing. On the basis of this dynamic model, three versions of sliding mode control are analyzed and designed to control five system outputs with only two inputs. When used in complicated operations, the effectiveness of the controllers is analyzed using analytical investigation and numerical simulation. Results indicate the effectiveness of the control algorithms and the proposed dynamic model. The control algorithms asymptotically stabilize the system with finite-time convergences, remaining robust amid disturbances and parametric uncertainties.
A study of the stress wave factor technique for evaluation of composite materials
NASA Technical Reports Server (NTRS)
Duke, J. C., Jr.; Henneke, E. G., II; Kiernan, M. T.; Grosskopf, P. P.
1989-01-01
The acousto-ultrasonic approach for nondestructive evaluation provides a measurement procedure for quantifying the integrated effect of globally distributed damage characteristic of fiber reinforced composite materials. The evaluation procedure provides a stress wave factor that correlates closely with several material performance parameters. The procedure was investigated for a variety of materials including advanced composites, hybrid structure bonds, adhesive bonds, wood products, and wire rope. The research program focused primarily on development of fundamental understanding and applications advancements of acousto-ultrasonics for materials characterization. This involves characterization of materials for which detection, location, and identification of imperfections cannot at present be analyzed satisfactorily with mechanical performance prediction models. In addition to presenting definitive studies on application potentials, the understanding of the acousto-ultrasonic method as applied to advanced composites is reviewed.
Twisted versus braided magnetic flux ropes in coronal geometry. II. Comparative behaviour
NASA Astrophysics Data System (ADS)
Prior, C.; Yeates, A. R.
2016-06-01
Aims: Sigmoidal structures in the solar corona are commonly associated with magnetic flux ropes whose magnetic field lines are twisted about a mutual axis. Their dynamical evolution is well studied, with sufficient twisting leading to large-scale rotation (writhing) and vertical expansion, possibly leading to ejection. Here, we investigate the behaviour of flux ropes whose field lines have more complex entangled/braided configurations. Our hypothesis is that this internal structure will inhibit the large-scale morphological changes. Additionally, we investigate the influence of the background field within which the rope is embedded. Methods: A technique for generating tubular magnetic fields with arbitrary axial geometry and internal structure, introduced in part I of this study, provides the initial conditions for resistive-MHD simulations. The tubular fields are embedded in a linear force-free background, and we consider various internal structures for the tubular field, including both twisted and braided topologies. These embedded flux ropes are then evolved using a 3D MHD code. Results: Firstly, in a background where twisted flux ropes evolve through the expected non-linear writhing and vertical expansion, we find that flux ropes with sufficiently braided/entangled interiors show no such large-scale changes. Secondly, embedding a twisted flux rope in a background field with a sigmoidal inversion line leads to eventual reversal of the large-scale rotation. Thirdly, in some cases a braided flux rope splits due to reconnection into two twisted flux ropes of opposing chirality - a phenomenon previously observed in cylindrical configurations. Conclusions: Sufficiently complex entanglement of the magnetic field lines within a flux rope can suppress large-scale morphological changes of its axis, with magnetic energy reduced instead through reconnection and expansion. The structure of the background magnetic field can significantly affect the changing morphology of a flux rope.
Cluster electric current density measurements within a magnetic flux rope in the plasma sheet
NASA Technical Reports Server (NTRS)
Slavin, J. A.; Lepping, R. P.; Gjerloev, J.; Goldstein, M. L.; Fairfield, D. H.; Acuna, M. H.; Balogh, A.; Dunlop, M.; Kivelson, M. G.; Khurana, K.
2003-01-01
On August 22, 2001 all 4 Cluster spacecraft nearly simultaneously penetrated a magnetic flux rope in the tail. The flux rope encounter took place in the central plasma sheet, Beta(sub i) approx. 1-2, near the leading edge of a bursty bulk flow. The "time-of-flight" of the flux rope across the 4 spacecraft yielded V(sub x) approx. 700 km/s and a diameter of approx.1 R(sub e). The speed at which the flux rope moved over the spacecraft is in close agreement with the Cluster plasma measurements. The magnetic field profiles measured at each spacecraft were first modeled separately using the Lepping-Burlaga force-free flux rope model. The results indicated that the center of the flux rope passed northward (above) s/c 3, but southward (below) of s/c 1, 2 and 4. The peak electric currents along the central axis of the flux rope predicted by these single-s/c models were approx.15-19 nA/sq m. The 4-spacecraft Cluster magnetic field measurements provide a second means to determine the electric current density without any assumption regarding flux rope structure. The current profile determined using the curlometer technique was qualitatively similar to those determined by modeling the individual spacecraft magnetic field observations and yielded a peak current density of 17 nA/m2 near the central axis of the rope. However, the curlometer results also showed that the flux rope was not force-free with the component of the current density perpendicular to the magnetic field exceeding the parallel component over the forward half of the rope, perhaps due to the pressure gradients generated by the collision of the BBF with the inner magnetosphere. Hence, while the single-spacecraft models are very successful in fitting flux rope magnetic field and current variations, they do not provide a stringent test of the force-free condition.
Experimental study of a linear/non-linear flux rope
NASA Astrophysics Data System (ADS)
DeHaas, Timothy; Gekelman, Walter; Van Compernolle, Bart
2015-08-01
Flux ropes are magnetic structures of helical field lines, accompanied by spiraling currents. Commonly observed on the solar surface extending into the solar atmosphere, flux ropes are naturally occurring and have been observed by satellites in the near earth and in laboratory environments. In this experiment, a single flux rope (r = 2.5 cm, L = 1100 cm) was formed in the cylindrical, magnetized plasma of the Large Plasma Device (LaPD, L = 2200 cm, rplasma = 30 cm, no = 1012 cm-3, Te = 4 eV, He). The flux rope was generated by a DC discharge between an electron emitting cathode and anode. This fixes the rope at its source while allowing it to freely move about the anode. At large currents (I > πr2B0c/2 L), the flux rope becomes helical in structure and oscillates about a central axis. Under varying Alfven speeds and injection current, the transition of the flux rope from stable to kink-unstable was examined. As it becomes non-linear, oscillations in the magnetic signals shift from sinusoidal to Sawtooth-like, associated with elliptical motion of the flux rope; or the signal becomes intermittent as its current density increases.
DO THE LEGS OF MAGNETIC CLOUDS CONTAIN TWISTED FLUX-ROPE MAGNETIC FIELDS?
DOE Office of Scientific and Technical Information (OSTI.GOV)
Owens, M. J.
2016-02-20
Magnetic clouds (MCs) are a subset of interplanetary coronal mass ejections (ICMEs) characterized primarily by a smooth rotation in the magnetic field direction indicative of the presence of a magnetic flux rope. Energetic particle signatures suggest MC flux ropes remain magnetically connected to the Sun at both ends, leading to widely used model of global MC structure as an extended flux rope, with a loop-like axis stretching out from the Sun into the heliosphere and back to the Sun. The time of flight of energetic particles, however, suggests shorter magnetic field line lengths than such a continuous twisted flux ropemore » would produce. In this study, two simple models are compared with observed flux rope axis orientations of 196 MCs to show that the flux rope structure is confined to the MC leading edge. The MC “legs,” which magnetically connect the flux rope to the Sun, are not recognizable as MCs and thus are unlikely to contain twisted flux rope fields. Spacecraft encounters with these non-flux rope legs may provide an explanation for the frequent observation of non-MC ICMEs.« less
33 CFR 164.76 - Towline and terminal gear for towing alongside and pushing ahead.
Code of Federal Regulations, 2010 CFR
2010-07-01
... towing alongside and pushing ahead. 164.76 Section 164.76 Navigation and Navigable Waters COAST GUARD... Towline and terminal gear for towing alongside and pushing ahead. The owner, master, or operator of each vessel towing alongside or pushing ahead shall ensure that the face wires, spring lines, and push gear...
Location and size of flux ropes in Titan's ionosphere
NASA Astrophysics Data System (ADS)
Martin, C.; Arridge, C. S.; Badman, S. V.; Dieval, C.
2017-12-01
Cassini magnetometer data was surveyed during Titan flybys to find 73 instances of flux rope signatures. A force free flux rope model was utilised to obtain the radii, maximum magnetic field and flux content of flux ropes that adhere to the force-free assumptions. We find that flux ropes at Titan are similar in size in km and flux content to the giant flux ropes identified at Venus, with a median radii of 280 km and an inter-quartile range of 270 km, a median maximum magnetic field of 8 nT with an inter-quartile range of 7 nT and a median flux content of 76 Wb with a large inter-quartile range of 250 Wb. We additionally investigate the occurrence of flux ropes with respect to the Sun-lit facing hemisphere (zenith angle) and the ram-side of Titan within Saturn's corotating magnetosphere (angle of attack of the incoming plasma flow). We find that flux ropes are more commonly detected in Sun-lit areas of Titan's ionosphere, as well as the ram-side of Titan. We see a statistically-significant absence of flux ropes in all SLT sectors in the night side of Titan and the anti-ram side of Titan. We also comment on the physical mechanisms associated with the production of these flux ropes, with particular attention on the variability of Titan's environment in Saturn's magnetosphere.
Charging of moving surfaces by corona discharges sustained in air
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Jun-Chieh, E-mail: junchwan@umich.edu; Kushner, Mark J., E-mail: mjkush@umich.edu; Zhang, Daihua, E-mail: dhzhang@tju.edu.cn
Atmospheric pressure corona discharges are used in electrophotographic (EP) printing technologies for charging imaging surfaces such as photoconductors. A typical corona discharge consists of a wire (or wire array) biased with a few hundred volts of dc plus a few kV of ac voltage. An electric discharge is produced around the corona wire from which electrons drift towards and charge the underlying dielectric surface. The surface charging reduces the voltage drop across the gap between the corona wire and the dielectric surface, which then terminates the discharge, as in a dielectric barrier discharge. In printing applications, this underlying surface ismore » continuously moving throughout the charging process. For example, previously charged surfaces, which had reduced the local electric field and terminated the local discharge, are translated out of the field of view and are replaced with uncharged surface. The uncharged surface produces a rebound in the electric field in the vicinity of the corona wire which in turn results in re-ignition of the discharge. The discharge, so reignited, is then asymmetric. We found that in the idealized corona charging system we investigated, a negatively dc biased corona blade with a dielectric covered ground electrode, the discharge is initially sustained by electron impact ionization from the bulk plasma and then dominated by ionization from sheath accelerated secondary electrons. Depending on the speed of the underlying surface, the periodic re-ignition of the discharge can produce an oscillatory charging pattern on the moving surface.« less
Double the Fun with Two-Person, One-Rope Jump Rope
ERIC Educational Resources Information Center
Heumann, Kristin J.; Murray, Steven Ross
2018-01-01
One popular activity within physical education curricula today is jump rope. Jump rope is recognized as an excellent activity for developing motor skills and the affective domain, and it aligns with several recommended outcomes for physical education listed by the SHAPE America--Society of Health and Physical Educators. This article describes…
Teaching Jump Rope to Children with Visual Impairments
ERIC Educational Resources Information Center
Lieberman, Lauren J.; Schedlin, Haley; Pierce, Tristan
2009-01-01
This article presents strategies for jumping rope for children with visual impairments. Giving choices related to the types of rope and the use of mats is important. In addition, using appropriate instructional strategies and modifications will make jumping rope a skill that the children will enjoy and will lead to their involvement in other…
Testing a new flux rope model using the HELCATS CME catalogue
NASA Astrophysics Data System (ADS)
Rouillard, Alexis Paul; Lavarra, Michael
2017-04-01
We present a magnetically-driven flux rope model that computes the forces acting on a twisted magnetic flux rope from the Sun to 1AU. This model assumes a more realistic flux rope geometry than assumed before by these types of models. The balance of force is computed in an analogous manner to the well-known Chen flux-rope model. The 3-D vector components of the magnetic field measured by a probe flying through the flux rope can be extracted for any flux rope orientation imposed near the Sun. We test this model through a parametric study and a systematic comparison of the model with the HELCATS catalogues (imagery and in situ). We also report on our investigations of other physical mechanisms such as the shift of flux-surfaces associated with the magnetic forces acting to accelerate the flux rope from the lower to upper corona. Finally, we present an evaluation of this model for space-weather predictions. This work was partly funded by the HELCATS project under the FP7 EU contract number 606692.
NASA Astrophysics Data System (ADS)
Ma, Jianxin; Zhang, Junjie
2015-03-01
A novel full-duplex fiber-wireless link based on single sideband (SSB) optical millimeter (mm)-wave with 10 Gbit/s 4-pulse amplitude modulation (PAM) signal is proposed to provide alternative wired and 40 GHz wireless accesses for the user terminals. The SSB optical mm-wave with 4-PAM signal consists of two tones: one bears the 4-PAM signal and the other is unmodulated with high power. After transmission over the fiber to the hybrid optical network unit (HONU), the SSB optical mm-wave signal can be decomposed by fiber Bragg gratings (FBGs) as the SSB optical mm-wave signal with reduced carrier-to-sideband ratio (the baseband 4-PAM optical signal) and the uplink optical carrier for the wireless (wired) access. This makes the HONU free from the laser source. For the uplink, since the wireless access signal is converted to the baseband by power detection, both the transmitter in the HONU and the receiver in optical line terminal (OLT) are co-shared for both wireless and wired accesses, which makes the full duplex link much simpler. In our scheme, the optical electrical field of the square-root increment level 4-PAM signal assures an equal level spacing receiving for both the downlink wired and wireless accesses. Since the downlink wireless signal is down-converted to the baseband by power detection, RF local oscillator is unnecessary. To confirm the feasibility of our proposed scheme, a simulation full duplex link with 40 GHz SSB optical mm-wave with 10 Gbit/s 4-PAM signal is built. The simulation results show that both down- and up-links for either wired or wireless access can keep good performance even if the link length of the SSMF is extended to 40 km.
Thermal Evolution of a Failed Flux Rope Eruption Revealed by Temperature Maps
NASA Astrophysics Data System (ADS)
Song, H.; Zhang, J.; CHEN, Y.
2013-12-01
Flux rope is generally considered to be the fundamental magnetic configuration of a coronal mass ejection (CME). Recent observations suggest that hot channel or blob structures during the eruptions be the direct observational manifestation of flux ropes. In this study, we report our analysis of thermal evolution of a failed solar eruption with an apparent flux rope embedded. The thermal structure of the eruption is revealed through differential emission measure (DEM) analysis technique, which shows detailed temperature maps in both high spatial resolution and high temperature resolution based on SDO/AIA observations. Our results show that the flux rope exists in the corona before the eruption, and its temperature can quickly rise to over 10 MK within one minute of the eruption. The correlation study between the flux rope temperature and the soft x-ray flux suggests that the flux rope should be heated through the direct thermal energy release of magnetic reconnection. Further, we study the kinematic evolution process of the flux rope, in an effort to find the physical mechanism that prevents the magnetic rope eruption to become a full coronal mass ejection. This kind of study using temperature maps might reveal where and when magnetic reconnection takes place during solar eruptions.
SLIPPING MAGNETIC RECONNECTION TRIGGERING A SOLAR ERUPTION OF A TRIANGLE-SHAPED FLAG FLUX ROPE
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Ting; Zhang, Jun, E-mail: liting@nao.cas.cn, E-mail: zjun@nao.cas.cn
2014-08-10
We report the first simultaneous activities of the slipping motion of flare loops and a slipping eruption of a flux rope in 131 Å and 94 Å channels on 2014 February 2. The east hook-like flare ribbon propagated with a slipping motion at a speed of about 50 km s{sup –1}, which lasted about 40 minutes and extended by more than 100 Mm, but the west flare ribbon moved in the opposite direction with a speed of 30 km s{sup –1}. At the later phase of flare activity, there was a well developed ''bi-fan'' system of flare loops. The east footpoints ofmore » the flux rope showed an apparent slipping motion along the hook of the ribbon. Simultaneously, the fine structures of the flux rope rose up rapidly at a speed of 130 km s{sup –1}, much faster than that of the whole flux rope. We infer that the east footpoints of the flux rope are successively heated by a slipping magnetic reconnection during the flare, which results in the apparent slippage of the flux rope. The slipping motion delineates a ''triangle-shaped flag surface'' of the flux rope, implying that the topology of a flux rope is more complex than anticipated.« less
NASA Astrophysics Data System (ADS)
Lowder, Chris; Yeates, Anthony
2017-09-01
Formed through magnetic field shearing and reconnection in the solar corona, magnetic flux ropes are structures of twisted magnetic field, threaded along an axis. Their evolution and potential eruption are of great importance for space weather. Here we describe a new methodology for the automated detection of flux ropes in simulated magnetic fields, utilizing field-line helicity. Our Flux Rope Detection and Organization (FRoDO) code, which measures the magnetic flux and helicity content of pre-erupting flux ropes over time, as well as detecting eruptions, is publicly available. As a first demonstration, the code is applied to the output from a time-dependent magnetofrictional model, spanning 1996 June 15-2014 February 10. Over this period, 1561 erupting and 2099 non-erupting magnetic flux ropes are detected, tracked, and characterized. For this particular model data, erupting flux ropes have a mean net helicity magnitude of 2.66× {10}43 Mx2, while non-erupting flux ropes have a significantly lower mean of 4.04× {10}42 Mx2, although there is overlap between the two distributions. Similarly, the mean unsigned magnetic flux for erupting flux ropes is 4.04× {10}21 Mx, significantly higher than the mean value of 7.05× {10}20 Mx for non-erupting ropes. These values for erupting flux ropes are within the broad range expected from observational and theoretical estimates, although the eruption rate in this particular model is lower than that of observed coronal mass ejections. In the future, the FRoDO code will prove to be a valuable tool for assessing the performance of different non-potential coronal simulations and comparing them with observations.
Mason, L.C.; Savidge, J.A.; Rodda, G.H.; Yackel Adams, A.A.
2011-01-01
Current methods for controlling the invasive Brown Treesnake (Boiga irregularis) on Guam include a modified minnow trap with a live mouse lure. We investigated the effects on capture success of augmenting these traps with scented guide ropes leading to trap entrances. Initial screening of scent preferences was based on time spent in scented and unscented arms of a Y-maze. Preferences of large and small snakes were scored for six different prey scents (live and carrion gecko, skink, and mouse). Large snakes spent more time in the maze arm scented with live gecko and carrion gecko, whereas small snakes spent more time in the arm scented with carrion mouse and carrion gecko. After the laboratory study, a pilot trapping session was conducted in the field using three treatments (live mouse-scented ropes, carrion gecko-scented ropes, and carrion mouse-scented ropes) and two controls (traps with unscented guide ropes and those with no ropes attached). Contrary to laboratory results, live mouse-scented ropes were most effective. We conducted a second trapping session using live mouse-scented ropes as well as the two controls used in the pilot study. For snakes of below-average to average condition, the number of captures for traps with live mouse-scented ropes was higher than for traps with no ropes. However, for snakes of above-average condition, there were no differences in capture rates between trap treatments. Overall, treatment effects were weaker than latent individual heterogeneity and the influence of snake body size, with large snakes trapped more readily. ?? 2011 Society for the Study of Amphibians and Reptiles.
Magnetohydrodynamic simulations of the ejection of a magnetic flux rope
NASA Astrophysics Data System (ADS)
Pagano, P.; Mackay, D. H.; Poedts, S.
2013-06-01
Context. Coronal mass ejections (CME's) are one of the most violent phenomena found on the Sun. One model to explain their occurrence is the flux rope ejection model. In this model, magnetic flux ropes form slowly over time periods of days to weeks. They then lose equilibrium and are ejected from the solar corona over a few hours. The contrasting time scales of formation and ejection pose a serious problem for numerical simulations. Aims: We simulate the whole life span of a flux rope from slow formation to rapid ejection and investigate whether magnetic flux ropes formed from a continuous magnetic field distribution, during a quasi-static evolution, can erupt to produce a CME. Methods: To model the full life span of magnetic flux ropes we couple two models. The global non-linear force-free field (GNLFFF) evolution model is used to follow the quasi-static formation of a flux rope. The MHD code ARMVAC is used to simulate the production of a CME through the loss of equilibrium and ejection of this flux rope. Results: We show that the two distinct models may be successfully coupled and that the flux rope is ejected out of our simulation box, where the outer boundary is placed at 2.5 R⊙. The plasma expelled during the flux rope ejection travels outward at a speed of 100 km s-1, which is consistent with the observed speed of CMEs in the low corona. Conclusions: Our work shows that flux ropes formed in the GNLFFF can lead to the ejection of a mass loaded magnetic flux rope in full MHD simulations. Coupling the two distinct models opens up a new avenue of research to investigate phenomena where different phases of their evolution occur on drastically different time scales. Movies are available in electronic form at http://www.aanda.org
Shi, Huantong; Zou, Xiaobing; Wang, Xinxin
2017-12-01
The physical process of electrical explosion of wires in vacuum is featured with the surface discharge along the wire, which generates the corona plasma layer and terminates the Joule heating of the wire core. In this paper, a fiber-array probe was designed to directly measure the radiation of surface arc with spatial and temporal resolution. The radiation of the exploding wire was casted to the section of an optical-fiber-array by a lens and transmitted to PIN diodes and finally collected with an oscilloscope. This probe enables direct diagnostics of the evolution of surface discharge with high temporal resolution and certain spatial resolution. The radiation of a tungsten wire driven by a positive current pulse was measured, and results showed that surface discharge initiates near the cathode and propagates toward the anode with a speed of 7.7 ± 1.6 mm/ns; further estimations showed that this process is responsible for the "conical" structure of the exploding wire.
NASA Astrophysics Data System (ADS)
Shi, Huantong; Zou, Xiaobing; Wang, Xinxin
2017-12-01
The physical process of electrical explosion of wires in vacuum is featured with the surface discharge along the wire, which generates the corona plasma layer and terminates the Joule heating of the wire core. In this paper, a fiber-array probe was designed to directly measure the radiation of surface arc with spatial and temporal resolution. The radiation of the exploding wire was casted to the section of an optical-fiber-array by a lens and transmitted to PIN diodes and finally collected with an oscilloscope. This probe enables direct diagnostics of the evolution of surface discharge with high temporal resolution and certain spatial resolution. The radiation of a tungsten wire driven by a positive current pulse was measured, and results showed that surface discharge initiates near the cathode and propagates toward the anode with a speed of 7.7 ± 1.6 mm/ns; further estimations showed that this process is responsible for the "conical" structure of the exploding wire.
The performance of cable braids and terminations to lightning induced transients
NASA Technical Reports Server (NTRS)
Crofts, David
1991-01-01
The latest specification detailing the test waveforms for indirect lightning transients as applied to aircraft wiring systems specify very high voltages and currents. Although considerable data exists for measuring cable screen leakage using such methods as surface transfer impedance and bulk cable injection, there is little data on the likely core transient level that is likely to be induced from these threats. In particular, the new Waveform 5 at very high current levels (10 kA) is reputed to cause severe cable damage. A range of representative cables were made with various screen termination techniques and screening levels. These were tested first to determine their relative screening performance and then they were subjected to lightning transient testing to all the specified waveforms. Core voltages were measured for each test. Tests were also performed on bundles with fewer wires to determine the failure criteria with Waveform 5 and these tests also include flat conductor cables. The test showed that correctly terminated cable bundles performed well in all the tests and would provide a high level of protection to the electronic systems. The use of overbraides, provided the individual screens are well terminated, appears to be unnecessary.
30 CFR 57.19021 - Minimum rope strength.
Code of Federal Regulations, 2011 CFR
2011-07-01
...=Static Load×4.0. (b) Friction drum ropes. For rope lengths less than 4,000 feet: Minimum Value=Static Load×(7.0−0.0005L) For rope lengths 4,000 feet or greater: Minimum Value=Static Load×5.0. (c) Tail....19021 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL...
30 CFR 57.19021 - Minimum rope strength.
Code of Federal Regulations, 2010 CFR
2010-07-01
...=Static Load×4.0. (b) Friction drum ropes. For rope lengths less than 4,000 feet: Minimum Value=Static Load×(7.0−0.0005L) For rope lengths 4,000 feet or greater: Minimum Value=Static Load×5.0. (c) Tail....19021 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL...
Strawberry Shortcake and Other Jumping Rope Ideas.
ERIC Educational Resources Information Center
Adams, Polly K.; Taylor, Michaell K.
Information, guidelines, and activities for jumping rope are given. A short history of jumping rope explains how it evolved from a spring ritual for men to a play activity involving mostly young girls. Physical and cultural reasons are given as to why jumping rope has been more a sport for girls than for boys. Research studies are noted which show…
Modeling Magnetic Flux-Ropes Structures
NASA Astrophysics Data System (ADS)
Nieves-Chinchilla, T.; Linton, M.; Hidalgo, M. A. U.; Vourlidas, A.; Savani, N.; Szabo, A.; Farrugia, C. J.; Yu, W.
2015-12-01
Flux-ropes are usually associated with magnetic structures embedded in the interplanetary Coronal Mass Ejections (ICMEs) with a depressed proton temperature (called Magnetic Clouds, MCs). However, small-scale flux-ropes in the solar wind are also identified with different formation, evolution, and dynamic involved. We present an analytical model to describe magnetic flux-rope topologies. The model is generalized to different grades of complexity. It extends the circular-cylindrical concept of Hidalgo et al. (2002) by introducing a general form for the radial dependence of the current density. This generalization provides information on the force distribution inside the flux rope in addition to the usual parameters of flux-rope geometrical information and orientation. The generalized model provides flexibility for implementation in 3-D MHD simulations.
The ancient art of laying rope
NASA Astrophysics Data System (ADS)
Bohr, J.; Olsen, K.
2011-03-01
We describe a geometrical property of helical structures and show how it accounts for the early art of rope-making. Helices have a maximum number of rotations that can be added to them — and it is shown that this is a geometrical feature, not a material property. This geometrical insight explains why nearly identically appearing ropes can be made from very different materials and it is also the reason behind the unyielding nature of ropes. Maximally rotated strands behave as zero-twist structures. Hence, under strain they neither rotate in one direction nor in the other. The necessity for the rope to be stretched while being laid, known from Egyptian tomb scenes, follows straightforwardly, as does the function of the top, an old tool for laying ropes.
Lunar Module Wiring Design Considerations and Failure Modes
NASA Technical Reports Server (NTRS)
Interbartolo, Michael
2009-01-01
This slide presentation reviews the considerations for the design of wiring for the Lunar Module. Included are a review of the choice of conductors and insulations, the wire splicing (i.e., crimping, and soldering), the wire connectors, and the fabrication of the wire harnesses. The problems in fabrication include the wires being the wrong length, the damage due to the sharp edges, the requried use of temproary protective covers and inadequate training. The problems in the wire harness installation include damge from sharp eges, work on adjacent harnesses, connector damage, and breaking wires. Engineering suggestions from the Apollo-era in reference to the conductors that are reviewed include: the use of plated conductors, and the use of alloys for stronger wiring. In refernce to insulation, the suggestions from Apollo era include the use of polymer tape-wrap wire insulation due to the light weight, however, other types of modern insulation might be more cost-effective. In reference to wire splices and terminal boards the suggestions from the Apollo Era include the use of crimp splices as superior to solder splices, joining multiple wire to a common point using modular plug-ins might be more reliable, but are heavier than crimp splicing. For connectors, the lessons from the Apollo era indicate that a rear environmental seal that does not require additional potting is preferred, and pins should be crimped or welded to the incoming wires and be removable from the rear of the connector.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Ting; Hou, Yijun; Zhang, Jun
We present the quasi-periodic slipping motion of flux-rope structures prior to the onset of an eruptive X-class flare on 2015 March 11, obtained by the Interface Region Imaging Spectrograph and the Solar Dynamics Observatory . The slipping motion occurred at the north part of the flux rope and seemed to successively peel off the flux rope. The speed of the slippage was 30−40 km s{sup −1}, with an average period of 130 ± 30 s. The Si iv λ 1402.77 line showed a redshift of 10−30 km s{sup −1} and a line width of 50−120 km s{sup −1} at themore » west legs of slipping structures, indicative of reconnection downflow. The slipping motion lasted about 40 minutes, and the flux rope started to rise up slowly at the late stage of the slippage. Then an X2.1 flare was initiated, and the flux rope was impulsively accelerated. One of the flare ribbons swept across a negative-polarity sunspot, and the penumbral segments of the sunspot decayed rapidly after the flare. We studied the magnetic topology at the flaring region, and the results showed the existence of a twisted flux rope, together with quasi-separatrix layer (QSL) structures binding the flux rope. Our observations imply that quasi-periodic slipping magnetic reconnection occurs along the flux-rope-related QSLs in the preflare stage, which drives the later eruption of the flux rope and the associated flare.« less
MHD Simulations of the Eruption of Coronal Flux Ropes under Coronal Streamers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fan, Yuhong, E-mail: yfan@ucar.edu
Using three-dimensional magnetohydrodynamic (MHD) simulations, we investigate the eruption of coronal flux ropes underlying coronal streamers and the development of a prominence eruption. We initialize a quasi-steady solution of a coronal helmet streamer, into which we impose at the lower boundary the slow emergence of a part of a twisted magnetic torus. As a result, a quasi-equilibrium flux rope is built up under the streamer. With varying streamer sizes and different lengths and total twists of the flux rope that emerges, we found different scenarios for the evolution from quasi-equilibrium to eruption. In the cases with a broad streamer, themore » flux rope remains well confined until there is sufficient twist such that it first develops the kink instability and evolves through a sequence of kinked, confined states with increasing height until it eventually develops a “hernia-like” ejective eruption. For significantly twisted flux ropes, prominence condensations form in the dips of the twisted field lines due to runaway radiative cooling. Once formed, the prominence-carrying field becomes significantly non-force-free due to the weight of the prominence, despite having low plasma β . As the flux rope erupts, the prominence erupts, showing substantial draining along the legs of the erupting flux rope. The prominence may not show a kinked morphology even though the flux rope becomes kinked. On the other hand, in the case with a narrow streamer, the flux rope with less than one wind of twist can erupt via the onset of the torus instability.« less
Slow rise and partial eruption of a double-decker filament. II. A double flux rope model
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kliem, Bernhard; Török, Tibor; Titov, Viacheslav S.
2014-09-10
Force-free equilibria containing two vertically arranged magnetic flux ropes of like chirality and current direction are considered as a model for split filaments/prominences and filament-sigmoid systems. Such equilibria are constructed analytically through an extension of the methods developed in Titov and Démoulin and numerically through an evolutionary sequence including shear flows, flux emergence, and flux cancellation in the photospheric boundary. It is demonstrated that the analytical equilibria are stable if an external toroidal (shear) field component exceeding a threshold value is included. If this component decreases sufficiently, then both flux ropes turn unstable for conditions typical of solar active regions,more » with the lower rope typically becoming unstable first. Either both flux ropes erupt upward, or only the upper rope erupts while the lower rope reconnects with the ambient flux low in the corona and is destroyed. However, for shear field strengths staying somewhat above the threshold value, the configuration also admits evolutions which lead to partial eruptions with only the upper flux rope becoming unstable and the lower one remaining in place. This can be triggered by a transfer of flux and current from the lower to the upper rope, as suggested by the observations of a split filament in Paper I. It can also result from tether-cutting reconnection with the ambient flux at the X-type structure between the flux ropes, which similarly influences their stability properties in opposite ways. This is demonstrated for the numerically constructed equilibrium.« less
NEW VACUUM SOLAR TELESCOPE OBSERVATIONS OF A FLUX ROPE TRACKED BY A FILAMENT ACTIVATION
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, Shuhong; Zhang, Jun; Liu, Zhong
2014-04-01
One main goal of the New Vacuum Solar Telescope (NVST) which is located at the Fuxian Solar Observatory is to image the Sun at high resolution. Based on the high spatial and temporal resolution NVST Hα data and combined with the simultaneous observations from the Solar Dynamics Observatory for the first time, we investigate a flux rope tracked by filament activation. The filament material is initially located at one end of the flux rope and fills in a section of the rope; the filament is then activated by magnetic field cancellation. The activated filament rises and flows along helical threads,more » tracking the twisted flux rope structure. The length of the flux rope is about 75 Mm, the average width of its individual threads is 1.11 Mm, and the estimated twist is 1π. The flux rope appears as a dark structure in Hα images, a partial dark and partial bright structure in 304 Å, and as a bright structure in 171 Å and 131 Å images. During this process, the overlying coronal loops are quite steady since the filament is confined within the flux rope and does not erupt successfully. It seems that, for the event in this study, the filament is located and confined within the flux rope threads, instead of being suspended in the dips of twisted magnetic flux.« less
Experimental study of a linear/non-linear flux rope
DOE Office of Scientific and Technical Information (OSTI.GOV)
DeHaas, Timothy; Gekelman, Walter; Van Compernolle, Bart
2015-08-15
Flux ropes are magnetic structures of helical field lines, accompanied by spiraling currents. Commonly observed on the solar surface extending into the solar atmosphere, flux ropes are naturally occurring and have been observed by satellites in the near earth and in laboratory environments. In this experiment, a single flux rope (r = 2.5 cm, L = 1100 cm) was formed in the cylindrical, magnetized plasma of the Large Plasma Device (LaPD, L = 2200 cm, r{sub plasma} = 30 cm, n{sub o} = 10{sup 12 }cm{sup −3}, T{sub e} = 4 eV, He). The flux rope was generated by a DC discharge between an electron emitting cathode and anode. This fixes the rope at its source while allowingmore » it to freely move about the anode. At large currents (I > πr{sup 2}B{sub 0}c/2 L), the flux rope becomes helical in structure and oscillates about a central axis. Under varying Alfven speeds and injection current, the transition of the flux rope from stable to kink-unstable was examined. As it becomes non-linear, oscillations in the magnetic signals shift from sinusoidal to Sawtooth-like, associated with elliptical motion of the flux rope; or the signal becomes intermittent as its current density increases.« less
Rope culture of the kelp Laminaria groenlandica in Alaska
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ellis, R.J.; Calvin, N.I.
1981-02-01
This paper is an account of rope culture of the brown seaweed or kelp, Laminaria groenlandica, in Alaska. It describes the placement of the ropes, time of first appearance of young L. groenlandica, size of the plants at various ages, and other life history features applicable to the use of rope for the culture of seaweeds in Alaska. (Refs. 3).
Hiestand, Laurie
2011-11-01
In this study I tested Benson Ginsburg's theory that dogs should show diminished ability, compared to wolves, in orienting in three-dimensional space and manipulating objects sequentially. Dogs of all ages and juvenile wolves should do poorly on these measures, but at some time before sexual maturity, the juvenile wolves should begin improving to the level of adult wolves. Two adult and seven juvenile wolves were compared with 40 adult German shepherds. The initial task was to pull a single rope suspended from the ceiling; complexity was increased by the addition of ropes and by changing spatial configurations. Adult wolf performance was consistently successful across all tests and requirements. Juvenile wolves had little difficulty with one and two rope tests, but did more poorly in the three rope tests. The behavior of the dogs grouped into four profiles (# of dogs): non-responders (6), one rope (15), two rope (14), and three rope responders (5).
The Role of Kinetic Alfven Waves in Plasma Transport in an Ion-scale Flux Rope
NASA Astrophysics Data System (ADS)
Tang, B.; Li, W.; Wang, C.; Dai, L.
2017-12-01
Magnetic flux ropes, if generated by multiply X-line reconnections, would be born as a crater type one, meaning the plasma density within is relatively high. They will then evolve into typical flux ropes as plasma are transported away along the magnetic field lines [Zhang et al., 2010]. In this study, we report an ion-scale flux rope observed by MMS on November 28, 2016, which is accompanied by strong kinetic Alfven waves (KAW). The related wave parallel electric field can effectively accelerate electrons inside the flux rope by Landau resonance, resulting into a significant decrease of the electron at 90° pitch angle. The change of electron pitch angle distribution would cause the rapid plasma transport along the magnetic field lines, and help the flux rope evolve into a strong magnetic core in a short time. This wave-particle interaction would be a candidate mechanism to explain the rareness of crater flux ropes in reality.
Madsen, Nina A H; Aarsæther, Karl G; Herrmann, Bent
2017-01-01
Demersal Seining is an active fishing method applying two long seine ropes and a seine net. Demersal seining relies on fish responding to the seine rope as it moves during the fishing process. The seine ropes and net are deployed in a specific pattern encircling an area on the seabed. In some variants of demersal seining the haul-in procedure includes a towing phase where the fishing vessel moves forward before starting to winch in the seine ropes. The initial seine rope encircled area, the gradual change in it during the haul-in process and the fish's reaction to the moving seine ropes play an important role in the catch performance of demersal seine fishing. The current study investigates this subject by applying computer simulation models for demersal seine fishing. The demersal seine fishing is dynamic in nature and therefore a dynamic model, SeineSolver is applied for simulating the physical behaviour of the seine ropes during the fishing process. Information about the seine rope behaviour is used as input to another simulation tool, SeineFish that predicts the catch performance of the demersal seine fishing process. SeineFish implements a simple model for how fish at the seabed reacts to an approaching seine rope. Here, the SeineSolver and SeineFish tools are applied to investigate catching performance for a Norwegian demersal seine fishery targeting cod (Gadus morhua) in the coastal zone. The effect of seine rope layout pattern and the duration of the towing phase are investigated. Among the four different layout patterns investigated, the square layout pattern was predicted to perform best; catching 69%-86% more fish than would be obtained with the rectangular layout pattern. Inclusion of a towing phase in the fishing process was found to increase the catch performance for all layout patterns. For the square layout pattern, inclusion of a towing phase of 15 or 35 minutes increased the catch performance by respectively 37% and 48% compared to fishing without a towing phase. These results highlights the importance of the selected seine rope layout pattern and the duration of the towing phase when fishermen try to maximize the catch performance of their fishery. To our knowledge this is the first time the combination of models for the physical behaviour of seine ropes and for fish behaviour in response to seine rope movements have been applied to predict catch performance for demersal seining.
Madsen, Nina A. H.; Aarsæther, Karl G.; Herrmann, Bent
2017-01-01
Demersal Seining is an active fishing method applying two long seine ropes and a seine net. Demersal seining relies on fish responding to the seine rope as it moves during the fishing process. The seine ropes and net are deployed in a specific pattern encircling an area on the seabed. In some variants of demersal seining the haul-in procedure includes a towing phase where the fishing vessel moves forward before starting to winch in the seine ropes. The initial seine rope encircled area, the gradual change in it during the haul-in process and the fish's reaction to the moving seine ropes play an important role in the catch performance of demersal seine fishing. The current study investigates this subject by applying computer simulation models for demersal seine fishing. The demersal seine fishing is dynamic in nature and therefore a dynamic model, SeineSolver is applied for simulating the physical behaviour of the seine ropes during the fishing process. Information about the seine rope behaviour is used as input to another simulation tool, SeineFish that predicts the catch performance of the demersal seine fishing process. SeineFish implements a simple model for how fish at the seabed reacts to an approaching seine rope. Here, the SeineSolver and SeineFish tools are applied to investigate catching performance for a Norwegian demersal seine fishery targeting cod (Gadus morhua) in the coastal zone. The effect of seine rope layout pattern and the duration of the towing phase are investigated. Among the four different layout patterns investigated, the square layout pattern was predicted to perform best; catching 69%-86% more fish than would be obtained with the rectangular layout pattern. Inclusion of a towing phase in the fishing process was found to increase the catch performance for all layout patterns. For the square layout pattern, inclusion of a towing phase of 15 or 35 minutes increased the catch performance by respectively 37% and 48% compared to fishing without a towing phase. These results highlights the importance of the selected seine rope layout pattern and the duration of the towing phase when fishermen try to maximize the catch performance of their fishery. To our knowledge this is the first time the combination of models for the physical behaviour of seine ropes and for fish behaviour in response to seine rope movements have been applied to predict catch performance for demersal seining. PMID:28771583
2010-03-01
14 FIGURE 18: TUNNEL AND ROPE CLIMB...15 Tunnel and Rope Climb: Participants were required to run through a tunnel and ascend a rope ladder at the end; Figure 18: Tunnel and Rope...de la massagerie tels que PDA, telephones intelligents, Blackberry , etc. Note
Evolution of flux ropes in the magnetotail: A three-dimensional global hybrid simulation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lu, S.; State Key Laboratory of Space Weather, National Space Science Center, Chinese Academy of Sciences, Beijing; Lin, Y.
2015-05-15
Flux ropes in the Earth's magnetotail are widely believed to play a crucial role in energy transport during substorms and the generation of energetic particles. Previous kinetic simulations are limited to the local-scale regime, and thus cannot be used to study the structure associated with the geomagnetic field and the global-scale evolution of the flux ropes. Here, the evolution of flux ropes in the magnetotail under a steady southward interplanetary magnetic field are studied with a newly developed three-dimensional global hybrid simulation model for dynamics ranging from the ion Larmor radius to the global convection time scales. Magnetic reconnection withmore » multiple X-lines is found to take place in the near-tail current sheet at geocentric solar magnetospheric distances x=−30R{sub E}∼−15R{sub E} around the equatorial plane (z=0). The magnetotail reconnection layer is turbulent, with a nonuniform structure and unsteady evolution, and exhibits properties of typical collisionless fast reconnection with the Hall effect. A number of small-scale flux ropes are generated through the multiple X-line reconnection. The diameter of the flux ropes is several R{sub E}, and the spatial scale of the flux ropes in the dawn-dusk direction is on the order of several R{sub E} and does not extend across the entire section of the magnetotail, contrary to previous models and MHD simulation results and showing the importance of the three-dimensional effects. The nonuniform and unsteady multiple X-line reconnection with particle kinetic effects leads to various kinds of flux rope evolution: The small-scale flux ropes propagate earthward or tailward after formation, and eventually merge into the near-Earth region or the mid-/distant-tail plasmoid, respectively. During the propagation, some of the flux ropes can be tilted in the geocentric solar magnetospheric (x,y) plane with respect to the y (dawn-dusk) axis. Coalescence between flux ropes is also observed. At the same time, the evolution of the flux ropes in the multiple X-line reconnection layer can also lead to the acceleration and heating of ions.« less
ROPES reveals past land cover and pollen productivity estimates from single pollen records
NASA Astrophysics Data System (ADS)
Theuerkauf, Martin; Couwenberg, John
2018-04-01
Quantitative reconstructions of past vegetation cover commonly require pollen productivity estimates (PPEs). PPEs are calibrated in extensive and rather cumbersome surface-sample studies, and are so far only available for selected regions. Moreover, it may be questioned whether present-day pollen-landcover relationships are valid for palaeo-situations. We here introduce the ROPES approach that simultaneously derives PPEs and mean plant abundances from single pollen records. ROPES requires pollen counts and pollen accumulation rates (PARs, grains cm-2 year-1). Pollen counts are used to reconstruct plant abundances following the REVEALS approach. The principle of ROPES is that changes in plant abundance are linearly represented in observed PAR values. For example, if the PAR of pine doubles, so should the REVEALS reconstructed abundance of pine. Consequently, if a REVEALS reconstruction is ‘correct’ (i.e. ‘correct’ PPEs are used) the ratio ‘PAR over REVEALS’ is constant for each taxon along all samples of a record. With incorrect PPEs, the ratio will instead vary. ROPES starts from random (likely incorrect) PPEs, but then adjusts them using an optimization algorithm with the aim to minimize variation in the ‘PAR over REVEALS’ ratio across the record. ROPES thus simultaneously calculates mean plant abundances and PPEs. We illustrate the approach with test applications on nine synthetic pollen records. The results show that good performance of ROPES requires data sets with high underlying variation, many samples and low noise in the PAR data. ROPES can deliver first landcover reconstructions in regions for which PPEs are not yet available. The PPEs provided by ROPES may then allow for further REVEALS-based reconstructions. Similarly, ROPES can provide insight in pollen productivity during distinct periods of the past such as the Lateglacial. We see a potential to study spatial and temporal variation in pollen productivity for example in relation to site parameters, climate and land use. It may even be possible to detect expansion of non-pollen producing areas in a landscape. Overall, ROPES will help produce more accurate landcover reconstructions and expand reconstructions into new study regions and non-analogue situations of the past. ROPES will be available within the R package DISQOVER.
NASA Astrophysics Data System (ADS)
Isavnin, A.; Vourlidas, A.; Kilpua, E. K. J.
2014-06-01
Flux ropes ejected from the Sun may change their geometrical orientation during their evolution, which directly affects their geoeffectiveness. Therefore, it is crucial to understand how solar flux ropes evolve in the heliosphere to improve our space-weather forecasting tools. We present a follow-up study of the concepts described by Isavnin, Vourlidas, and Kilpua ( Solar Phys. 284, 203, 2013). We analyze 14 coronal mass ejections (CMEs), with clear flux-rope signatures, observed during the decay of Solar Cycle 23 and rise of Solar Cycle 24. First, we estimate initial orientations of the flux ropes at the origin using extreme-ultraviolet observations of post-eruption arcades and/or eruptive prominences. Then we reconstruct multi-viewpoint coronagraph observations of the CMEs from ≈ 2 to 30 R⊙ with a three-dimensional geometric representation of a flux rope to determine their geometrical parameters. Finally, we propagate the flux ropes from ≈ 30 R⊙ to 1 AU through MHD-simulated background solar wind while using in-situ measurements at 1 AU of the associated magnetic cloud as a constraint for the propagation technique. This methodology allows us to estimate the flux-rope orientation all the way from the Sun to 1 AU. We find that while the flux-ropes' deflection occurs predominantly below 30 R⊙, a significant amount of deflection and rotation happens between 30 R⊙ and 1 AU. We compare the flux-rope orientation to the local orientation of the heliospheric current sheet (HCS). We find that slow flux ropes tend to align with the streams of slow solar wind in the inner heliosphere. During the solar-cycle minimum the slow solar-wind channel as well as the HCS usually occupy the area in the vicinity of the solar equatorial plane, which in the past led researchers to the hypothesis that flux ropes align with the HCS. Our results show that exceptions from this rule are explained by interaction with the Parker-spiraled background magnetic field, which dominates over the magnetic interaction with the HCS in the inner heliosphere at least during solar-minimum conditions.
NASA Astrophysics Data System (ADS)
Huang, Zong-Ying; Pu, Zu-Yin; Xiao, Chi-Jie; Xong, Qui-Gang; Fu, Sui-Yan; Xie, Lun; Shi, Quan-Qi; Cao, Jin-Bin; Liu, Zhen-Xing; Shen, Cao; Shi, Jian-Kui; Lu, Li; Wang, Nai-Quan; Chen, Tao; Fritz, T.; Glasmeier, K.-H.; Daly, P.; Reme, H.
2004-04-01
From 11:10 to 11:40UT on January 26, 2001 the four Cluster II spacecraft were located in the duskside high latitude regions of the magnetosheath and magnetosheath boundary layer (MSBL). During this time Interval the interplanetary magnetic field (IMF) had a negative Bz component. A detailed study on the multiple flux ropes (MFRs) observed in this period is conducted in this paper. It is found that: (1) The multiple flux ropes in the high latitude MSBL appeared quasi-periodically with a repeated time period of about 78s, which is much shorter than the averaged occurring period (about 8-11min) of the flux transfer events (FTEs) at the dayside magnetopause (MP). (2) All the flux ropes observed in this event had a strong core magnetic field. The axial orientation of the most flux ropes is found to lie in the direction of the minimum magnetic field variance; a few flux ropes had their axes lying in the direction of the middle magnetic field variance; while for the remainders their principle axes could not be determined by the method of Principal Axis Analysis (PAA). The reason that causes this complexity relys on the different trajectories of the spacecraft passing through the flux ropes. (3) Each flux rope had a good corresponding HT frame of reference in which it was in a quasi-steady state. All flux ropes moved along the surface of the MP in a similar direction indicating that these flux ropes all came from the dawnside low latitude. Their radial scale is 1-2RE, comparable to the normal diameter of FTEs observed atthe dayside MP. (4) The energetic ions originated from the magnetosphere flowed out to the magnetosheath on the whole, while the solar wind plasma flowed into the magnetosphere along the axis of the flux ropes. The flux ropes offered channels for the transport of the solar wind plasma into the magnetosphere and the escaping of the magnetospheric plasma into the interplanetary space. (5) Each event was accompanied by an enhanced reversal of the dusk-dawn electric field, which could be identified to be the convective electric field in nature.
Geometrical Relationship Between Interplanetary Flux Ropes and Their Solar Sources
NASA Astrophysics Data System (ADS)
Marubashi, K.; Akiyama, S.; Yashiro, S.; Gopalswamy, N.; Cho, K.-S.; Park, Y.-D.
2015-05-01
We investigated the physical connection between interplanetary flux ropes (IFRs) near Earth and coronal mass ejections (CMEs) by comparing the magnetic field structures of IFRs and CME source regions. The analysis is based on the list of 54 pairs of ICMEs (interplanetary coronal mass ejections) and CMEs that are taken to be the most probable solar source events. We first attempted to identify the flux rope structure in each of the 54 ICMEs by fitting models with a cylinder and torus magnetic field geometry, both with a force-free field structure. This analysis determined the possible geometries of the identified flux ropes. Then we compared the flux rope geometries with the magnetic field structure of the solar source regions. We obtained the following results: (1) Flux rope structures are seen in 51 ICMEs out of the 54. The result implies that all ICMEs have an intrinsic flux rope structure, if the three exceptional cases are attributed to unfavorable observation conditions. (2) It is possible to find flux rope geometries with the main axis orientation close to the orientation of the magnetic polarity inversion line (PIL) in the solar source regions, the differences being less than 25°. (3) The helicity sign of an IFR is strongly controlled by the location of the solar source: flux ropes with positive (negative) helicity are associated with sources in the southern (northern) hemisphere (six exceptions were found). (4) Over two-thirds of the sources in the northern hemisphere are concentrated along PILs with orientations of 45° ± 30° (measured clockwise from the east), and over two-thirds in the southern hemisphere along PILs with orientations of 135° ± 30°, both corresponding to the Hale boundaries. These results strongly support the idea that a flux rope with the main axis parallel to the PIL erupts in a CME and that the erupted flux rope propagates through the interplanetary space with its orientation maintained and is observed as an IFR.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Joshi, Navin Chandra; Inoue, Satoshi; Magara, Tetsuya, E-mail: navin@khu.ac.kr, E-mail: njoshi98@gmail.com
2014-11-01
We present observations of compound flux rope formation, which occurred on 2014 January 1, via merging of two nearby filament channels, the associated dynamics, and its stability using multiwavelength data. We also discuss the dynamics of cool and hot plasma moving along the newly formed compound flux rope. The merging started after the interaction between the southern leg of the northward filament and the northern leg of the southward filament at ≈01:21 UT and continued until a compound flux rope formed at ≈01:33 UT. During the merging, the cool filament plasma heated up and started to move along both sidesmore » of the compound flux rope, i.e., toward the north (≈265 km s{sup –1}) and south (≈118 km s{sup –1}) from the point of merging. After traveling a distance of ≈150 Mm toward the north, the plasma cooled down and started to return back to the south (≈14 km s{sup –1}) after ≈02:00 UT. The observations provide a clear example of compound flux rope formation via merging of two different flux ropes and the occurrence of a flare through tether cutting reconnection. However, the compound flux rope remained stable in the corona and had a confined eruption. The coronal magnetic field decay index measurements revealed that both the filaments and the compound flux rope axis lie within the stability domain (decay index <1.5), which may be the possible cause for their stability. The present study also deals with the relationship between the filament's chirality (sinistral) and the helicity (positive) of the surrounding flux rope.« less
NASA Astrophysics Data System (ADS)
Pal, Sanchita; Gopalswamy, Nat; Nandy, Dibyendu; Akiyama, Sachiko; Yashiro, Seiji; Makela, Pertti; Xie, Hong
2017-12-01
We compare the magnetic helicity in the 2013 March 17–18 interplanetary coronal mass ejection (ICME) flux rope at 1 au and in its solar counterpart. The progenitor coronal mass ejection (CME) erupted on 2013 March 15 from NOAA active region 11692 and is associated with an M1.1 flare. We derive the source region reconnection flux using the post-eruption arcade (PEA) method that uses the photospheric magnetogram and the area under the PEA. The geometrical properties of the near-Sun flux rope is obtained by forward-modeling of white-light CME observations. Combining the geometrical properties and the reconnection flux, we extract the magnetic properties of the CME flux rope. We derive the magnetic helicity of the flux rope using its magnetic and geometric properties obtained near the Sun and at 1 au. We use a constant-α force-free cylindrical flux rope model fit to the in situ observations in order to derive the magnetic and geometric information of the 1 au ICME. We find a good correspondence in both amplitude and sign of the helicity between the ICME and the CME, assuming a semi-circular (half torus) ICME flux rope with a length of π au. We find that about 83% of the total flux rope helicity at 1 au is injected by the magnetic reconnection in the low corona. We discuss the effect of assuming flux rope length in the derived value of the magnetic helicity. This study connecting the helicity of magnetic flux ropes through the Sun–Earth system has important implications for the origin of helicity in the interplanetary medium and the topology of ICME flux ropes at 1 au and hence their space weather consequences.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nishida, Keisuke; Shibata, Kazunari; Nishizuka, Naoto, E-mail: nishida@kwasan.kyoto-u.ac.jp
2013-10-01
We investigated the dynamic evolution of a three-dimensional (3D) flux rope eruption and magnetic reconnection process in a solar flare by simply extending the two-dimensional (2D) resistive magnetohydrodynamic simulation model of solar flares with low β plasma to a 3D model. We succeeded in reproducing a current sheet and bi-directional reconnection outflows just below the flux rope during the eruption in our 3D simulations. We calculated four cases of a strongly twisted flux rope and a weakly twisted flux rope in 2D and 3D simulations. The time evolution of a weakly twisted flux rope in the 3D simulation shows behaviorsmore » similar to those of the 2D simulation, while a strongly twisted flux rope in the 3D simulation clearly shows a different time evolution from the 2D simulation except for the initial phase evolution. The ejection speeds of both strongly and weakly twisted flux ropes in 3D simulations are larger than in the 2D simulations, and the reconnection rates in 3D cases are also larger than in the 2D cases. This indicates positive feedback between the ejection speed of a flux rope and the reconnection rate even in the 3D simulation, and we conclude that the plasmoid-induced reconnection model can be applied to 3D. We also found that small-scale plasmoids are formed inside a current sheet and make it turbulent. These small-scale plasmoid ejections have a role in locally increasing the reconnection rate intermittently as observed in solar flares, coupled with a global eruption of a flux rope.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Guo, Rui; Gao, Liming, E-mail: liming.gao@sjtu.edu.cn; Li, Ming, E-mail: mingli90@sjtu.edu.cn
As the continuous shrinkage of the interconnect line width in microelectronics devices, there is a growing concern about the electromigration (EM) failure of bonding wire. In addition, an innovative Ag–8Au–3Pd alloy wire has shown promise as an economical substitute for gold wire interconnects due to the cost pressure of gold in the last decade. In present study of the Ag–8Au–3Pd alloy wire, the surface diffusion occupied the dominant position during EM failure, and the activation energy was found to be 0.61 eV. In order to reveal the failure mechanism, the cross-sections of the Ag–8Au–3Pd alloy wire during EM were preparedmore » by focused ion beam (FIB) micro-machining for electron backscatter diffraction (EBSD) analysis. The microstructure evolution of the Ag–8Au–3Pd alloy wire was characterized by the grain size and grain boundary. As a result, the EM failure originates in the atom transportation, which causes grain size increasing and atom diffusion on the wire surface. - Highlights: • The activation energy of Ag–8Au–3Pd alloy wire was obtained as 0.61 eV. • During EM, the silver atoms diffused from negative to the positive terminal on the wire surface. • The microstructure (grain size and grain boundary) was characterized by FIB-EBSD. • During EM, the atom transportation was found to cause grain size growth and atom diffusion on the wire surface.« less
Code of Federal Regulations, 2014 CFR
2014-04-01
... and approved as pressure-terminal connectors recognized for the wire size used. Star washers or other... as screws and star washers or equivalent). [40 FR 58752, Dec. 18, 1975. Redesignated at 44 FR 20679...
Code of Federal Regulations, 2011 CFR
2011-04-01
... and approved as pressure-terminal connectors recognized for the wire size used. Star washers or other... as screws and star washers or equivalent). [40 FR 58752, Dec. 18, 1975. Redesignated at 44 FR 20679...
Code of Federal Regulations, 2012 CFR
2012-04-01
... and approved as pressure-terminal connectors recognized for the wire size used. Star washers or other... as screws and star washers or equivalent). [40 FR 58752, Dec. 18, 1975. Redesignated at 44 FR 20679...
Code of Federal Regulations, 2013 CFR
2013-04-01
... and approved as pressure-terminal connectors recognized for the wire size used. Star washers or other... as screws and star washers or equivalent). [40 FR 58752, Dec. 18, 1975. Redesignated at 44 FR 20679...
18 CFR 367.3970 - Account 397, Communication equipment.
Code of Federal Regulations, 2012 CFR
2012-04-01
... items: (1) Amplifiers. (2) Antennae. (3) Booths. (4) Cables. (5) Carrier terminal equipment. (6...) Remote control equipment and lines. (23) Sending keys. (24) Storage batteries. (25) Switchboards. (26... and cable wires. ...
18 CFR 367.3970 - Account 397, Communication equipment.
Code of Federal Regulations, 2013 CFR
2013-04-01
... items: (1) Amplifiers. (2) Antennae. (3) Booths. (4) Cables. (5) Carrier terminal equipment. (6...) Remote control equipment and lines. (23) Sending keys. (24) Storage batteries. (25) Switchboards. (26... and cable wires. ...
18 CFR 367.3970 - Account 397, Communication equipment.
Code of Federal Regulations, 2010 CFR
2010-04-01
... items: (1) Amplifiers. (2) Antennae. (3) Booths. (4) Cables. (5) Carrier terminal equipment. (6...) Remote control equipment and lines. (23) Sending keys. (24) Storage batteries. (25) Switchboards. (26... and cable wires. ...
18 CFR 367.3970 - Account 397, Communication equipment.
Code of Federal Regulations, 2014 CFR
2014-04-01
... items: (1) Amplifiers. (2) Antennae. (3) Booths. (4) Cables. (5) Carrier terminal equipment. (6...) Remote control equipment and lines. (23) Sending keys. (24) Storage batteries. (25) Switchboards. (26... and cable wires. ...
18 CFR 367.3970 - Account 397, Communication equipment.
Code of Federal Regulations, 2011 CFR
2011-04-01
... items: (1) Amplifiers. (2) Antennae. (3) Booths. (4) Cables. (5) Carrier terminal equipment. (6...) Remote control equipment and lines. (23) Sending keys. (24) Storage batteries. (25) Switchboards. (26... and cable wires. ...
ERIC Educational Resources Information Center
American School and University, 1983
1983-01-01
A campus computer center at Hofstra University (New York) that holds 70 terminals for student use was first a gymnasium, then a language laboratory. Strands of fiber optics are used for the necessary wiring. (MLF)
Measurement of large strains in ropes using plastic optical fibers
Williams, Jerry Gene; Smith, David Barton; Muhs, Jeffrey David
2006-02-14
A method for the direct measurement of large strains in ropes in situ using a plastic optical fiber, for example, perfluorocarbon or polymethyl methacrylate and Optical Time-Domain Reflectometer or other light time-of-flight measurement instrumentation. Protective sheaths and guides are incorporated to protect the plastic optical fiber. In one embodiment, a small rope is braided around the plastic optical fiber to impose lateral compressive forces to restrain the plastic optical fiber from slipping and thus experience the same strain as the rope. Methods are described for making reflective interfaces along the length of the plastic optical fiber and to provide the capability to measure strain within discrete segments of the rope. Interpretation of the data allows one to calculate the accumulated strain at any point in time and to determine if the rope has experienced local damage.
Physics of magnetic flux ropes
NASA Astrophysics Data System (ADS)
Russell, C. T.; Priest, E. R.; Lee, L. C.
The present work encompasses papers on the structure, waves, and instabilities of magnetic flux ropes (MFRs), photospheric flux tubes (PFTs), the structure and heating of coronal loops, solar prominences, coronal mass ejections and magnetic clouds, flux ropes in planetary ionospheres, the magnetopause, magnetospheric field-aligned currents and flux tubes, and the magnetotail. Attention is given to the equilibrium of MFRs, resistive instability, magnetic reconnection and turbulence in current sheets, dynamical effects and energy transport in intense flux tubes, waves in solar PFTs, twisted flux ropes in the solar corona, an electrodynamical model of solar flares, filament cooling and condensation in a sheared magnetic field, the magnetopause, the generation of twisted MFRs during magnetic reconnection, ionospheric flux ropes above the South Pole, substorms and MFR structures, evidence for flux ropes in the earth magnetotail, and MFRs in 3D MHD simulations.
Observing Flux Rope Formation During the Impulsive Phase of a Solar Eruption
NASA Astrophysics Data System (ADS)
Cheng, Xin; Zhang, J.; Yang, L.; Ding, M.
2011-05-01
Magnetic flux rope is believed to be an important structural component of coronal mass ejections (CMEs). While there exist much observational evidence of the flux rope post the eruption, e.g., as seen in remote-sensing coronagraph images or in-situ solar wind data, the direct observation of flux ropes during CME impulsive phase has been rare or non-exist. In this Letter, we present an unambiguous observation of a flux rope still in the formation phase in the low corona. The CME of interest occurred above the east limb on 2010 November 03 with footpoints partially blocked. The flux rope was seen as a blob of hot plasma in AIA 131 A passband (peak temperature 11 MK) rising from the core of the source active region, rapidly moving outward and stretching upward the surrounding background magnetic field. The stretched magnetic field seemed to curve-in, similar to the classical magnetic reconnection scenario in eruptive flares. The flux rope was also seen as a dark cavity in AIA 211 A passpand (2.0 MK) and 171 A passband (0.6 MK); in these relatively cool temperature bands, a bright rim clearly enclosed the dark cavity. The bright rim likely represents the pile-up of the surrounding coronal plasma compressed by the expanding flux rope. The composite structure seen in AIA multiple temperature bands is very similar to that in the corresponding coronagraph images, which consists of a bright leading edge and a dark cavity, commonly believed to be a flux rope.
NASA Technical Reports Server (NTRS)
Wu, S. T.; Guo, W. P.; Dryer, Murray
1996-01-01
The dynamical response of a helmet streamer to a flux rope escape from the sub-photosphere is examined in a physically self-consistent manner within the approximation of axisymmetric three-dimensional magnetohydrodynamics (i.e., so-called '2 1/2 D'). In contrast to the previous planar analyses of Paper 1 (Wu, Guo, and Wang), the present study shows, with the inclusion of out-of-plane components of magnetic and velocity fields, that the magnetic configuration represents a helical flux rope instead of a planar bubble as shown in Paper 1. Because of this more physically-realistic configuration, we are able to examine the dynamical evolution of the helical flux rope's interaction with the helmet streamer. This process leads to the formation of two parts of the solar mass ejection: (i) the expulsion of the helmet dome due to eruption of this flux rope, and (ii) the flux rope's eruption itself. When this two-part feature propagates out to the interplanetary space, it exhibits all the physical characteristics of observed interplanetary magnetic clouds. These numerical simulations also show that the dynamical behavior of the streamer-flux rope system has three distinct states: (i) quasi-equilibrium, (ii) non-equilibrium, and (iii) eruptive state depending on the energy level of the flux rope.
How Well Can the Observed Flux Ropes in the Solar Wind be Fitted by a Uniform-twist Flux Rope Model?
NASA Astrophysics Data System (ADS)
Wang, Y.
2015-12-01
In the solar wind, flux ropes, e.g., magnetic clouds (MCs), are a frequently observational phenomenon. Their magnetic field configuration or the way that the field lines wind around the flux rope axis is one of the most important information to understand the formation and evolution of the observed flux ropes. Most MCs are believed to be in the force-free state, and widely modeled by the Lundquist force-free solution, in which the twist of the field line increases from zero at the axis to infinity at the boundary. However, Lundquist solution is not the only form of a force-free magnetic field. Some studies based on suprathermal electron observations and models have shown that MCs may carry magnetic field lines more likely to be uniformly twisted. The nonlinear force-free field extrapolation of solar magnetic field also suggests that the field lines of a flux rope twist limitedly. In this study, we have developed a velocity-modified uniform-twist force-free flux rope model, and fit observed MCs with this model. By using this approach, we test how well the observed MCs can be fitted into a uniform-twist flux rope. Some interesting results will be given in this presentation.
Electrical termination techniques
NASA Technical Reports Server (NTRS)
Oakey, W. E.; Schleicher, R. R.
1976-01-01
A technical review of high reliability electrical terminations for electronic equipment was made. Seven techniques were selected from this review for further investigation, experimental work, and preliminary testing. From the preliminary test results, four techniques were selected for final testing and evaluation. These four were: (1) induction soldering, (2) wire wrap, (3) percussive arc welding, and (4) resistance welding. Of these four, induction soldering was selected as the best technique in terms of minimizing operator errors, controlling temperature and time, minimizing joint contamination, and ultimately producing a reliable, uniform, and reusable electrical termination.
A map of terminal regulators of neuronal identity in Caenorhabditis elegans
2016-01-01
Our present day understanding of nervous system development is an amalgam of insights gained from studying different aspects and stages of nervous system development in a variety of invertebrate and vertebrate model systems, with each model system making its own distinctive set of contributions. One aspect of nervous system development that has been among the most extensively studied in the nematode Caenorhabditis elegans is the nature of the gene regulatory programs that specify hardwired, terminal cellular identities. I first summarize a number of maps (anatomical, functional, and molecular) that describe the terminal identity of individual neurons in the C. elegans nervous system. I then provide a comprehensive summary of regulatory factors that specify terminal identities in the nervous system, synthesizing these past studies into a regulatory map of cellular identities in the C. elegans nervous system. This map shows that for three quarters of all neurons in the C. elegans nervous system, regulatory factors that control terminal identity features are known. In‐depth studies of specific neuron types have revealed that regulatory factors rarely act alone, but rather act cooperatively in neuron‐type specific combinations. In most cases examined so far, distinct, biochemically unlinked terminal identity features are coregulated via cooperatively acting transcription factors, termed terminal selectors, but there are also cases in which distinct identity features are controlled in a piecemeal fashion by independent regulatory inputs. The regulatory map also illustrates that identity‐defining transcription factors are reemployed in distinct combinations in different neuron types. However, the same transcription factor can drive terminal differentiation in neurons that are unrelated by lineage, unrelated by function, connectivity and neurotransmitter deployment. Lastly, the regulatory map illustrates the preponderance of homeodomain transcription factors in the control of terminal identities, suggesting that these factors have ancient, phylogenetically conserved roles in controlling terminal neuronal differentiation in the nervous system. WIREs Dev Biol 2016, 5:474–498. doi: 10.1002/wdev.233 For further resources related to this article, please visit the WIREs website. PMID:27136279
49 CFR 229.89 - Jumpers; cable connections.
Code of Federal Regulations, 2013 CFR
2013-10-01
...) Cable and jumper connections between locomotive may not have any of the following conditions: (1) Broken or badly chafed insulation. (2) Broken plugs, receptacles or terminals. (3) Broken or protruding strands of wire. ...
49 CFR 229.89 - Jumpers; cable connections.
Code of Federal Regulations, 2011 CFR
2011-10-01
...) Cable and jumper connections between locomotive may not have any of the following conditions: (1) Broken or badly chafed insulation. (2) Broken plugs, receptacles or terminals. (3) Broken or protruding strands of wire. ...
49 CFR 229.89 - Jumpers; cable connections.
Code of Federal Regulations, 2012 CFR
2012-10-01
...) Cable and jumper connections between locomotive may not have any of the following conditions: (1) Broken or badly chafed insulation. (2) Broken plugs, receptacles or terminals. (3) Broken or protruding strands of wire. ...
49 CFR 229.89 - Jumpers; cable connections.
Code of Federal Regulations, 2014 CFR
2014-10-01
...) Cable and jumper connections between locomotive may not have any of the following conditions: (1) Broken or badly chafed insulation. (2) Broken plugs, receptacles or terminals. (3) Broken or protruding strands of wire. ...
Seo, KyoChul
2017-08-01
[Purpose] The purpose of this study was to examine the effect of a dance music jump rope exercise on changes Pulmonary Function and body mass index in female overweight subjects in their 20's. [Subjects and Methods] The subjects were randomly assigned to the dance music jump rope exercise group and the stationary cycle exercise group. All subjects have conducted the exercises three times a week for four weeks. Pulmonary function was evaluated using a spirometer, and body mass index was evaluated using an InBody 3.0. [Results] The findings of this study showed significant improvements in the voluntary capacity and body mass index of the experimental groups. Vital capacity was higher in the music jump rope exercise group than the stationary cycle exercise group, and body mass index was lower in the music jump rope exercise group than the stationary cycle exercise group. [Conclusion] This study showed that the dance music jump rope exercise can be used to improve vital capacity and body mass index.
Magnetospheric Multiscale Mission Observations of Magnetic Flux Ropes in the Earth's Plasma Sheet
NASA Astrophysics Data System (ADS)
Slavin, J. A.; Akhavan-Tafti, M.; Poh, G.; Le, G.; Russell, C. T.; Nakamura, R.; Baumjohann, W.; Torbert, R. B.; Gershman, D. J.; Pollock, C. J.; Giles, B. L.; Moore, T. E.; Burch, J. L.
2017-12-01
A major discovery by the Cluster mission and the previous generation of science missions is the presence of earthward and tailward moving magnetic flux ropes in the Earth's plasma sheet. However, the lack of high-time resolution plasma measurements severely limited progress concerning the formation and evolution of these reconnection generated structures. We use high-time resolution magnetic and electric field and plasma measurements from the Magnetospheric Multiscale mission's first tail season to investigate: 1) the distribution of flux rope diameters relative to the local ion and electron inertial lengths; 2) the internal force balance sustaining these structures; and 3) the magnetic connectivity of the flux ropes to the Earth and/or the interplanetary medium; 4) the specific entropy of earthward moving flux ropes and the possible effect of "buoyancy" on how deep they penetrate into the inner magnetosphere; and 5) evidence for coalescence of adjacent flux ropes and/or the division of existing flux ropes through the formation of secondary X-lines. The results of these initial analyses will be discussed in terms of their implications for reconnection-driven magnetospheric dynamics and substorms.
Pre-eruptive Magnetic Reconnection within a Multi-flux-rope System in the Solar Corona
NASA Astrophysics Data System (ADS)
Awasthi, Arun Kumar; Liu, Rui; Wang, Haimin; Wang, Yuming; Shen, Chenglong
2018-04-01
The solar corona is frequently disrupted by coronal mass ejections (CMEs), whose core structure is believed to be a flux rope made of helical magnetic field. This has become a “standard” picture; though, it remains elusive how the flux rope forms and evolves toward eruption. While one-third of the ejecta passing through spacecraft demonstrate a flux-rope structure, the rest have complex magnetic fields. Are they originating from a coherent flux rope, too? Here we investigate the source region of a complex ejecta, focusing on a flare precursor with definitive signatures of magnetic reconnection, i.e., nonthermal electrons, flaring plasma, and bidirectional outflowing blobs. Aided by nonlinear force-free field modeling, we conclude that the reconnection occurs within a system of multiple braided flux ropes with different degrees of coherency. The observation signifies the importance of internal structure and dynamics in understanding CMEs and in predicting their impacts on Earth.
NASA Astrophysics Data System (ADS)
Poh, G.; Slavin, J. A.; Lu, S.; Le, G.; Cassak, P.; Eastwood, J. P.; Ozturk, D. S.; Zou, S.; Nakamura, R.; Baumjohann, W.; Russell, C. T.; Gershman, D. J.; Giles, B. L.; Pollock, C.; Moore, T. E.; Torbert, R. B.; Burch, J. L.
2017-12-01
The formation of flux ropes is thought to be an integral part of the process that may have important consequences for the onset and subsequent rate of reconnection in the tail. Earthward flows, i.e. bursty bulk flows (BBFs), generate dipolarization fronts (DFs) as they interact with the closed magnetic flux in their path. Global hybrid simulations and THEMIS observations have shown that earthward-moving flux ropes can undergo magnetic reconnection with the near-Earth dipole field in the downtail region between the Near Earth Neutral Line and the near-Earth dipole field to create DFs-like signatures. In this study, we analyzed sequential "chains" of earthward-moving, ion-scale flux ropes embedded within DFs observed during MMS first tail season. MMS high-resolution plasma measurements indicate that these earthward flux ropes embedded in DFs have a mean bulk flow velocity and diameter of 250 km/s and 1000 km ( 2‒3 ion inertial length λi), respectively. Magnetic reconnection signatures preceding the flux rope/DF encounter were also observed. As the southward-pointing magnetic field in the leading edge of the flux rope reconnects with the northward-pointing geomagnetic field, the characteristic quadrupolar Hall magnetic field in the ion diffusion region and electron outflow jets in the north-south direction are observed. Our results strongly suggest that the earthward moving flux ropes brake and gradually dissipate due to magnetic reconnection with the near Earth magnetic field. We have also examined the occurrence rate of these dissipating flux ropes/DF events as a function of downtail distances.
Dynamics of Single Flux Rope in the Reconnection Scaling Experiment
NASA Astrophysics Data System (ADS)
Feng, Y.; Sears, J.; Intrator, T.; Weber, T.; Swan, H.; Dunn, J. P.; Gao, K.; Chapdelaine, L.
2013-12-01
A magnetic flux tube threaded by current is a flux rope with helically twisted field lines. In the Reconnection Scaling Experiment (RSX) we use a plasma gun to generate a single flux rope with a choice of axial boundary conditions. If this flux rope is driven hard enough, i.e., when J●B /B2 is larger than the kink instability threshold, we measure a helically distorted kinked structure. Rather than exploding in an Alfvén time, this kink appears to saturate to a steady amplitude, helical, gyrating flux rope, which persists as long as the plasma gun sources the current. To understand it, we have experimentally measured three-dimensional (3D) profiles of various quantities of this flux rope. These quantities include magnetic field B, plasma density n and potential φ, ion flow velocity vi, so that current density J, electron flow velocity ve and electron pressure Pe can also be derived. Consequently we can analyze the single flux rope dynamics systematically in 3D. Besides gyrating (writhe), we also find the flux rope has a spin (twist) center, around which the J×B - ▽Pe ≠ 0 suggesting that there should be other forces for the radial balance. We also find that there is a reverse current moving around with the flux rope at some locations, i.e. there are local induced currents that are not at all apparent from measurements outside the 3D volume. Work supported by LANL-DOE, DOE Fusion Energy Sciences DE-AC52-06NA25396, NASA Geospace NNHIOA044I Basic, CMSO, SULI, NUF.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Howard, T. A.; DeForest, C. E., E-mail: howard@boulder.swri.edu
We present a data-driven narrative of the launch and early evolution of the magnetic structure that gave rise to the coronal mass ejection (CME) on 2008 December 12. The structure formed on December 7 and launched early on December 12. We interpret this structure as a flux rope based on prelaunch morphology, postlaunch magnetic measurements, and the lack of large-scale magnetic reconnection signatures at launch. We ascribe three separate onset mechanisms to the complete disconnection of the flux rope from the Sun. It took 19 hr for the flux rope to be fully removed from the Sun, by which timemore » the segment that first disconnected was around 40 R {sub ☉} away. This implies that the original flux rope was stretched or broken; we provide evidence for a possible bisection. A transient dark arcade was observed on the Sun that was later obscured by a bright arcade, which we interpret as the strapping field stretching and magnetically reconnecting as it disconnected from the coronal field. We identify three separate structures in coronagraph images to be manifestations of the same original flux rope, and we describe the implications for CME interpretation. We cite the rotation in the central flux rope vector of the magnetic clouds observed in situ by ACE/Wind and STEREO-B as evidence of the kink instability of the eastern segment of the flux rope. Finally, we discuss possible alternative narratives, including multiple prelaunch magnetic structures and the nonflux rope scenario. Our results support the view that, in at least some CMEs, flux rope formation occurs before launch.« less
Observing Flux Rope Formation During the Impulsive Phase of a Solar Eruption
NASA Astrophysics Data System (ADS)
Cheng, X.; Zhang, J.; Liu, Y.; Ding, M. D.
2011-05-01
Magnetic flux ropes are believed to be an important structural component of coronal mass ejections (CMEs). While there exists much observational evidence of flux ropes after the eruption, e.g., as seen in remote-sensing coronagraph images or in situ solar wind data, the direct observation of flux ropes during CME impulsive phase has been rare. In this Letter, we present an unambiguous observation of a flux rope still in the formation phase in the low corona. The CME of interest occurred above the east limb on 2010 November 3 with footpoints partially blocked. The flux rope was seen as a bright blob of hot plasma in the Atmospheric Imaging Assembly (AIA) 131 Å passband (peak temperature ~11 MK) rising from the core of the source active region, rapidly moving outward and stretching the surrounding background magnetic field upward. The stretched magnetic field seemed to curve-in behind the core, similar to the classical magnetic reconnection scenario in eruptive flares. On the other hand, the flux rope appeared as a dark cavity in the AIA 211 Å passband (2.0 MK) and 171 Å passband (0.6 MK) in these relatively cool temperature bands, a bright rim clearly enclosed the dark cavity. The bright rim likely represents the pileup of the surrounding coronal plasma compressed by the expanding flux rope. The composite structure seen in AIA multiple temperature bands is very similar to that in the corresponding coronagraph images, which consists of a bright leading edge and a dark cavity, commonly believed to be a flux rope.
ERIC Educational Resources Information Center
Eler, Nebahat; Acar, Hakan
2018-01-01
The aim of this study is to examine the effects of rope-jump training program in physical education lessons on strength, speed and VO[subscript 2] max in 10-12 year old boys. 240 male students; rope-jump group (n = 120) and control group (n = 120) participated in the study. Rope-Jump group continued 10 weeks of regular physical education and sport…
A Model of Coronal Streamers with Underlying Flux Ropes
NASA Astrophysics Data System (ADS)
Cottaar, M.; Fan, Y.
2009-10-01
We present global two-dimensional axisymmetric isothermal MHD simulations of the dynamic evolution of a coronal helmet streamer, driven at the lower boundary by the emergence of a twisted flux rope. By varying both the detached toroidal and poloidal fluxes emerged into the corona, but fixing the normal flux distribution at the surface at the end of the emergence, we obtain solutions that either settle to a new steady state of a stable helmet streamer containing a flux rope, or result in a disruption of the helmet with the underlying flux rope being expelled in a coronal mass ejection (CME)-like eruption. In all of the cases studied, we find that the transition from a stable to an eruptive state takes place at a magnetic energy that is very close to the Aly open field energy. Furthermore, we find that the transition from a stable to an eruptive end state does not occur at a single critical value of the total relative magnetic helicity, but depends on the profile of the underlying flux rope. Cases where the detached flux rope contains a higher amount of self-helicity, i.e., higher internal twist or detached poloidal flux, are found to become eruptive at a significantly lower total helicity. For the eruptive cases, the detached flux rope after emergence first rises quasi-statically due to a gradual opening of the field lines at the edge of the streamer and a slow reconnection below the flux rope, which continues to slowly increase the amount of the detached flux. This decreases the downward magnetic tension on the flux rope. The dynamic eruption is initiated when the magnetic pressure gradient no longer decreases fast enough to balance the decrease in the magnetic tension. Later rapid reconnections below the flux rope are important for accelerating the flux rope. For the stable helmets, we find that no cavities are formed due to the simplifying assumption of isothermal energetics and the uniform density lower boundary condition. However during the eruption we see the development of the 3-part structure of a CME.
Analysis of Magnetic Flux Rope Chains Embedded in Martian Current Sheets Using MAVEN Data
NASA Astrophysics Data System (ADS)
Bowers, C. F.; DiBraccio, G. A.; Brain, D.; Hara, T.; Gruesbeck, J.; Espley, J. R.; Connerney, J. E. P.; Halekas, J. S.
2017-12-01
The magnetotail of Mars is formed as the interplanetary magnetic field (IMF) drapes around the planet's conducting ionosphere and localized crustal magnetic fields. In this scenario, a cross-tail current sheet separates the sunward and anti-sunward tail lobes. This tail current sheet is a highly dynamic region where magnetic reconnection is able to occur between the oppositely oriented fields. Magnetic flux ropes, a by-product of magnetic reconnection in the tail or in the ionosphere characterized by their helical outer wraps and strong axial core field, are commonly observed in the Martian magnetotail. An initial study using Mars Global Surveyor measurements reported a chain of flux ropes in the tail. During this event, 3 flux ropes were observed during a single traversal of the tail current sheet with a duration of 4 minutes. Here, we perform a statistical survey of these chain-of-flux-rope events to characterize their occurrence in the tail current sheet using Mars Atmosphere and Volatile EvolutioN (MAVEN) data. We implement the well-established technique of Minimum Variance Analysis to confirm the helical structure of the flux ropes and also determine local current sheet orientation. Thorough visual examination of more than 1600 orbits has resulted in the identification of 784 tail current sheet traversals. We determine the current sheet thickness to be on the order of 100-1000 km. From these current sheet observations, a subset of 30 events include embedded chain of flux ropes within the current sheet structure. We find that 87% of these flux rope chain events are identified in the southern latitude regions of Mars, associated with crustal fields. Their location suggests that magnetic reconnection occurring near crustal fields may be the source of these flux ropes. These statistical measurements of both current sheets and associated flux rope chains provide information about the complex magnetospheric dynamics at Mars, and how these dynamics affect atmospheric loss to space.
Global simulation of formation and evolution of plasmoid and flux-rope in the Earth's Magnetotail
NASA Astrophysics Data System (ADS)
Ge, Y.; Raeder, J.; Du, A.
2014-12-01
The observation of plasmoids and flux-ropes in the Earth's magnetotail was crucial to establish the simultaneous presence of multiple x-lines in the tail, and has become the basis for the Near Earth Neutral Line (NENL) model of substorms. While the "classical" NENL model envisions x-lines that extend across the entire tail, recent observations have shown that neither do the x-lines and resulting plasmoids encompass the entire tail, nor do the x-lines have to lie along the y-axis. The fragmentation of the tail by spatially and temporally limited x-lines has important consequences for the mass and energy budget of the tail. Recent ARTEMIS observations have shown that the plasmoids in the distant tail are limited in the Y direction and some flux ropes are tilted during their tailward propagation. Understanding their formation and evolution during their propagation through the magnetotail shall shred more light on the general energy and flux transport of the Earth's magnetosphere. In this study we simulate plasmoids and flux-ropes in the Earth's magnetotail using the Open Global Geospace Circulation Model (OpenGGCM). We investigate the generation mechanisms for tail plasmoids and flux-ropes and their evolution as they propagate in the magnetotail. The simulation results show that the limited extend of NENL controls the length or the Y scale of tail plasmoid and flux rope. In addition, by studying their 3D magnetic topology we find that the tilted flux rope forms due to a progressive spreading of reconnection line along the east-west direction, which produces and releases two ends of the flux rope at different times and in different speeds. By constructing a catalogue of observational signatures of plasmoid and flux rope we compare the differences of their signatures and find that large-scale plasmoids have much weaker core fields than that inside the small-scale flux ropes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carley, Eoin P.; Gallagher, Peter T.; Vilmer, Nicole, E-mail: eoin.carley@obspm.fr
Electron acceleration in the solar corona is often associated with flares and the eruption of twisted magnetic structures known as flux ropes. However, the locations and mechanisms of such particle acceleration during the flare and eruption are still subject to much investigation. Observing the exact sites of particle acceleration can help confirm how the flare and eruption are initiated and how they evolve. Here we use the Atmospheric Imaging Assembly to analyze a flare and erupting flux rope on 2014 April 18, while observations from the Nançay Radio Astronomy Facility allow us to diagnose the sites of electron acceleration duringmore » the eruption. Our analysis shows evidence of a pre-formed flux rope that slowly rises and becomes destabilized at the time of a C-class flare, plasma jet, and the escape of ≳75 keV electrons from the rope center into the corona. As the eruption proceeds, continued acceleration of electrons with energies of ∼5 keV occurs above the flux rope for a period over 5 minutes. At the flare peak, one site of electron acceleration is located close to the flare site, while another is driven by the erupting flux rope into the corona at speeds of up to 400 km s{sup −1}. Energetic electrons then fill the erupting volume, eventually allowing the flux rope legs to be clearly imaged from radio sources at 150–445 MHz. Following the analysis of Joshi et al. (2015), we conclude that the sites of energetic electrons are consistent with flux rope eruption via a tether cutting or flux cancellation scenario inside a magnetic fan-spine structure. In total, our radio observations allow us to better understand the evolution of a flux rope eruption and its associated electron acceleration sites, from eruption initiation to propagation into the corona.« less
A compact ultra-clean system for deploying radioactive sources inside the KamLAND detector
NASA Astrophysics Data System (ADS)
Banks, T. I.; Freedman, S. J.; Wallig, J.; Ybarrolaza, N.; Gando, A.; Gando, Y.; Ikeda, H.; Inoue, K.; Kishimoto, Y.; Koga, M.; Mitsui, T.; Nakamura, K.; Shimizu, I.; Shirai, J.; Suzuki, A.; Takemoto, Y.; Tamae, K.; Ueshima, K.; Watanabe, H.; Xu, B. D.; Yoshida, H.; Yoshida, S.; Kozlov, A.; Grant, C.; Keefer, G.; Piepke, A.; Bloxham, T.; Fujikawa, B. K.; Han, K.; Ichimura, K.; Murayama, H.; O`Donnell, T.; Steiner, H. M.; Winslow, L. A.; Dwyer, D. A.; McKeown, R. D.; Zhang, C.; Berger, B. E.; Lane, C. E.; Maricic, J.; Miletic, T.; Batygov, M.; Learned, J. G.; Matsuno, S.; Sakai, M.; Horton-Smith, G. A.; Downum, K. E.; Gratta, G.; Efremenko, Y.; Perevozchikov, O.; Karwowski, H. J.; Markoff, D. M.; Tornow, W.; Heeger, K. M.; Detwiler, J. A.; Enomoto, S.; Decowski, M. P.
2015-01-01
We describe a compact, ultra-clean device used to deploy radioactive sources along the vertical axis of the KamLAND liquid-scintillator neutrino detector for purposes of calibration. The device worked by paying out and reeling in precise lengths of a hanging, small-gauge wire rope (cable); an assortment of interchangeable radioactive sources could be attached to a weight at the end of the cable. All components exposed to the radiopure liquid scintillator were made of chemically compatible UHV-cleaned materials, primarily stainless steel, in order to avoid contaminating or degrading the scintillator. To prevent radon intrusion, the apparatus was enclosed in a hermetically sealed housing inside a glove box, and both volumes were regularly flushed with purified nitrogen gas. An infrared camera attached to the side of the housing permitted real-time visual monitoring of the cable's motion, and the system was controlled via a graphical user interface.
A Kinematic Analysis of Flat Leverage Mechanism of the Fourth Class for Manipulators
NASA Astrophysics Data System (ADS)
Tultayev, B.; Balbayev, G.; Zhauyt, A.
2017-09-01
Linkwork, in its early applications, consisted mainly of revolute-connected members and was widely used for converting the continuous rotation of a water wheel into a reciprocating motion suited to piston pumps. The piston-cylinder combination at the end of the line represents a prismatic pair, of course, but ahead of this there are only the revolute connections generally associated with linkwork. Agricola’s arrangements show wheel and pump-power source and point of work-fairly close together. Such compactness did not always prevail; link-works of magnificent proportions were also part of the past. A linkwork is a means of power transmission as well as being a motion transformer. Before the introduction of rope transmissions and the now universal electric wire, linkwork was employed for long-distance transmission of power. Gigantic linkages, principally for mine pumping operations, connected water wheels at the riverbank to pumps high up on the hillside.
NASA Astrophysics Data System (ADS)
Miranda, Rodrigo A.; Schelin, Adriane B.; Chian, Abraham C.-L.; Ferreira, José L.
2018-03-01
In a recent paper (Chian et al., 2016) it was shown that magnetic reconnection at the interface region between two magnetic flux ropes is responsible for the genesis of interplanetary intermittent turbulence. The normalized third-order moment (skewness) and the normalized fourth-order moment (kurtosis) display a quadratic relation with a parabolic shape that is commonly observed in observational data from turbulence in fluids and plasmas, and is linked to non-Gaussian fluctuations due to coherent structures. In this paper we perform a detailed study of the relation between the skewness and the kurtosis of the modulus of the magnetic field |B| during a triple interplanetary magnetic flux rope event. In addition, we investigate the skewness-kurtosis relation of two-point differences of |B| for the same event. The parabolic relation displays scale dependence and is found to be enhanced during magnetic reconnection, rendering support for the generation of non-Gaussian coherent structures via rope-rope magnetic reconnection. Our results also indicate that a direct coupling between the scales of magnetic flux ropes and the scales within the inertial subrange occurs in the solar wind.
A traffic analyzer for multiple SpaceWire links
NASA Astrophysics Data System (ADS)
Liu, Scige J.; Giusi, Giovanni; Di Giorgio, Anna M.; Vertolli, Nello; Galli, Emanuele; Biondi, David; Farina, Maria; Pezzuto, Stefano; Spinoglio, Luigi
2014-07-01
Modern space missions are becoming increasingly complex: the interconnection of the units in a satellite is now a network of terminals linked together through routers, where devices with different level of automation and intelligence share the same data-network. The traceability of the network transactions is performed mostly at terminal level through log analysis and hence it is difficult to verify in real time the reliability of the interconnections and the interchange protocols. To improve and ease the traffic analysis in a SpaceWire network we implemented a low-level link analyzer, with the specific goal to simplify the integration and test phases in the development of space instrumentation. The traffic analyzer collects signals coming from pod probes connected in-series on the interested links between two SpaceWire terminals. With respect to the standard traffic analyzers, the design of this new tool includes the possibility to internally reshape the LVDS signal. This improvement increases the robustness of the analyzer towards environmental noise effects and guarantees a deterministic delay on all analyzed signals. The analyzer core is implemented on a Xilinx FPGA, programmed to decode the bidirectional LVDS signals at Link and Network level. Successively, the core packetizes protocol characters in homogeneous sets of time ordered events. The analyzer provides time-tagging functionality for each characters set, with a precision down to the FPGA Clock, i.e. about 20nsec in the adopted HW environment. The use of a common time reference for each character stream allows synchronous performance measurements. The collected information is then routed to an external computer for quick analysis: this is done via high-speed USB2 connection. With this analyzer it is possible to verify the link performances in terms of induced delays in the transmitted signals. A case study focused on the analysis of the Time-Code synchronization in presence of a SpaceWire Router is shown in this paper as well.
Rope Hadronization and Strange Particle Production
NASA Astrophysics Data System (ADS)
Bierlich, Christian
2018-02-01
Rope Hadronization is a model extending the Lund string hadronization model to describe environments with many overlapping strings, such as high multiplicity pp collisions or AA collisions. Including effects of Rope Hadronization drastically improves description of strange/non-strange hadron ratios as function of event multiplicity in all systems from e+e- to AA. Implementation of Rope Hadronization in the MC event generators Dipsy and PYTHIA8 is discussed, as well as future prospects for jet studies and studies of small systems.
Regularized Biot-Savart Laws for Modeling Magnetic Flux Ropes
NASA Astrophysics Data System (ADS)
Titov, Viacheslav; Downs, Cooper; Mikic, Zoran; Torok, Tibor; Linker, Jon A.
2017-08-01
Many existing models assume that magnetic flux ropes play a key role in solar flares and coronal mass ejections (CMEs). It is therefore important to develop efficient methods for constructing flux-rope configurations constrained by observed magnetic data and the initial morphology of CMEs. As our new step in this direction, we have derived and implemented a compact analytical form that represents the magnetic field of a thin flux rope with an axis of arbitrary shape and a circular cross-section. This form implies that the flux rope carries axial current I and axial flux F, so that the respective magnetic field is a curl of the sum of toroidal and poloidal vector potentials proportional to I and F, respectively. The vector potentials are expressed in terms of Biot-Savart laws whose kernels are regularized at the rope axis. We regularized them in such a way that for a straight-line axis the form provides a cylindrical force-free flux rope with a parabolic profile of the axial current density. So far, we set the shape of the rope axis by tracking the polarity inversion lines of observed magnetograms and estimating its height and other parameters of the rope from a calculated potential field above these lines. In spite of this heuristic approach, we were able to successfully construct pre-eruption configurations for the 2009 February13 and 2011 October 1 CME events. These applications demonstrate that our regularized Biot-Savart laws are indeed a very flexible and efficient method for energizing initial configurations in MHD simulations of CMEs. We discuss possible ways of optimizing the axis paths and other extensions of the method in order to make it more useful and robust.Research supported by NSF, NASA's HSR and LWS Programs, and AFOSR.
Relaxation of flux ropes and magnetic reconnection in the Reconnection Scaling Experiment at LANL
NASA Astrophysics Data System (ADS)
Furno, I.; Intrator, T.; Hemsing, E.; Hsu, S.; Lapenta, G.; Abbate, S.
2004-12-01
Magnetic reconnection and plasma relaxation are studied in the Reconnection Scaling Experiment (RSX) with current carrying plasma columns (magnetic flux ropes). Using plasma guns, multiple flux ropes (Bθ ≤ 100 Gauss, L=90 cm, r≤3 cm) are generated in a three-dimensional (3D) cylindrical geometry and are observed to evolve dynamically during the injection of magnetic helicity. Detailed evolution of electron density, temperature, plasma potential and magnetic field structures is reconstructed experimentally and visible light emission is captured with a fast-gated, intensified CCD camera to provide insight into the global flux rope dynamics. Experiments with two flux ropes in collisional plasmas and in a strong axial guide field (Bz / Bθ > 10) suggest that magnetic reconnection plays an important role in the initial stages of flux rope evolution. During the early stages of the applied current drive (t≤ 20 τ Alfv´ {e}n), the flux ropes are observed to twist, partially coalesce and form a thin current sheet with a scale size comparable to that of the ion sound gyro-radius. Here, non-ideal terms in a generalized Ohm's Law appear to play a significant role in the 3D reconnection process as shown by the presence of a strong axial pressure gradient in the current sheet. In addition, a density perturbation with a structure characteristic of a kinetic Alfvén wave is observed to propagate axially in the current layer, anti-parallel to the induced sheet current. Later in the evolution, when a sufficient amount of helicity is injected into the system, a critical threshold for the kink instability is exceeded and the helical twisting of each individual flux rope can dominate the dynamics of the system. This may prevent the complete coalescence of the flux ropes.
Relaxation of flux ropes and magnetic reconnection in the Reconnection Scaling Experiment at LANL
NASA Astrophysics Data System (ADS)
Furno, Ivo
2004-11-01
Magnetic reconnection and plasma relaxation are studied in the Reconnection Scaling Experiment (RSX) with current carrying plasma columns (magnetic flux ropes). Using plasma guns, multiple flux ropes (B_pol < 100 Gauss, L=90 cm, r < 3 cm) are generated in a three-dimensional (3D) cylindrical geometry and are observed to evolve dynamically during the injection of magnetic helicity. Detailed evolution of electron density, temperature, plasma potential and magnetic field structures is reconstructed experimentally and visible light emission is captured with a fast-gated, intensified CCD camera to provide insight into the global flux rope dynamics. Experiments with two flux ropes in collisional plasmas and in a strong axial guide field (Bz / B_pol > 10) suggest that magnetic reconnection plays an important role in the initial stages of flux rope evolution. During the early stages of the applied current drive (t < 20τ_Alfven), the flux ropes are observed to twist, partially coalesce and form a thin current sheet with a scale size comparable to that of the ion sound gyro-radius. Here, non-ideal terms in a generalized Ohm's Law appear to play a significant role in the 3D reconnection process as shown by the presence of a strong axial pressure gradient in the current sheet. In addition, a density perturbation with a structure characteristic of a kinetic Alfvén wave is observed to propagate axially in the current layer, anti-parallel to the induced sheet current. Later in the evolution, when a sufficient amount of helicity is injected into the system, a critical threshold for the kink instability is exceeded and the helical twisting of each individual flux rope can dominate the dynamics of the system. This may prevent the complete coalescence of the flux ropes.
Decorte, Inge; Van Breedam, Wander; Van der Stede, Yves; Nauwynck, Hans J; De Regge, Nick; Cay, Ann Brigitte
2014-06-17
Oral fluid collected by means of ropes has the potential to replace serum for monitoring and surveillance of important swine pathogens. Until now, the most commonly used method to collect oral fluid is by hanging a cotton rope in a pen. However, concerns about the influence of rope material on subsequent immunological assays have been raised. In this study, we evaluated six different rope materials for the collection of oral fluid and the subsequent detection of total and PRRSV-specific antibodies of different isotypes in oral fluid collected from PRRSV-vaccinated and infected pigs. An initial experiment showed that IgA is the predominant antibody isotype in porcine saliva. Moreover, it was found that synthetic ropes may yield higher amounts of IgA, whereas all rope types seemed to be equally suitable for IgG collection. Although IgA is the predominant antibody isotype in porcine oral fluid, the PRRSV-specific IgA-based IPMA and ELISA tests were clearly not ideal for sensitive detection of PRRSV-specific IgA antibodies. In contrast, PRRSV-specific IgG in oral fluids was readily detected in PRRSV-specific IgG-based IPMA and ELISA tests, indicating that IgG is a more reliable isotype for monitoring PRRSV-specific antibody immunity in vaccinated/infected animals via oral fluids with the currently available tests. Since PRRSV-specific IgG detection seems more reliable than PRRSV-specific IgA detection for monitoring PRRSV-specific antibody immunity via oral fluids, and since all rope types yield equal amounts of IgG, it seems that the currently used cotton ropes are an appropriate choice for sample collection in PRRSV monitoring.
Modelling of power lines in lightning incidence calculations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mousa, A.M.; Srivastava, K.D.
1990-01-01
When applying the electrogeometric model to power lines to determine the frequency and characteristics of the collected lightning strokes, the power line has traditionally been represented by a set of horizontal wires, i.e. both the sag of the wires and the existence of the towers have been ignored. This approach has serious shortcomings including inability to determine the percentage of the strokes terminating on the towers, failure to correctly predict the effect of height on median current, and giving an approximate value for the number of collected strokes without telling the corresponding degree of error. This paper eliminates the abovemore » problems by presenting a computerized solution which takes into consideration the sag of the wires, the existence of the towers, and the inequality of the striking distances to towers and to wires. The features of the program are discussed in the paper, and some of its results are given.« less
NASA Astrophysics Data System (ADS)
Paul, Clayton R.
1991-06-01
Crosstalk is the unintentional electromagnetic coupling between circuits which are connected by parallel conductors that lie in close proximity to each other. Some examples are wires in cable harnesses or metallic lands on printed-circuit boards (PCB's). This unintended interaction between two or more circuits via their electromagnetic fields can cause interference problems. Signals from one circuit that couple to another circuit appear at the terminals of the devices that are interconnected by the wires. If these signals are of sufficient magnitude or spectral content, they may cause unintended operation of the device or a degradation in its performance. A summary of the standard models used for predicting crosstalk in various types of configurations is presented. The discussion focusses on the relative accuracies, regions of applicability, and computational complexity of the models. A simple explanation of the ability (or inability) of shielded wires and twisted pairs of wires to reduce the crosstalk is also given.
Advances in Engineering Software for Lift Transportation Systems
NASA Astrophysics Data System (ADS)
Kazakoff, Alexander Borisoff
2012-03-01
In this paper an attempt is performed at computer modelling of ropeway ski lift systems. The logic in these systems is based on a travel form between the two terminals, which operates with high capacity cabins, chairs, gondolas or draw-bars. Computer codes AUTOCAD, MATLAB and Compaq-Visual Fortran - version 6.6 are used in the computer modelling. The rope systems computer modelling is organized in two stages in this paper. The first stage is organization of the ground relief profile and a design of the lift system as a whole, according to the terrain profile and the climatic and atmospheric conditions. The ground profile is prepared by the geodesists and is presented in an AUTOCAD view. The next step is the design of the lift itself which is performed by programmes using the computer code MATLAB. The second stage of the computer modelling is performed after the optimization of the co-ordinates and the lift profile using the computer code MATLAB. Then the co-ordinates and the parameters are inserted into a program written in Compaq Visual Fortran - version 6.6., which calculates 171 lift parameters, organized in 42 tables. The objective of the work presented in this paper is an attempt at computer modelling of the design and parameters derivation of the rope way systems and their computer variation and optimization.
Plasmoids as magnetic flux ropes. [in geomagnetic tail
NASA Technical Reports Server (NTRS)
Moldwin, Mark B.; Hughes, W. J.
1991-01-01
A magnetic flux rope model is developed and used to determine whether the principal axis analysis (PAA) of magnetometer signatures from a single satellite pass is sufficient to obtain the magnetic topology of plasmoids. The model is also used to determine if plasmoid observations are best explained by the flux rope, closed loop, or large-amplitude wave picture. It was found that the principal axis directions is highly dependent on the satellite trajectory through the structure and, therefore, the PAA of magnetometer data from a single satellite pass is insufficient to differentiate between magnetic closed loop and flux rope models. Results also indicate that the flux rope model of plasmoid formation is well suited to unify the observations of various magnetic structures observed by ISEE 3.
Code of Federal Regulations, 2010 CFR
2010-01-01
... on electrical devices, including those on relays, interrupters, switches, contactors, terminal blocks and circuit breakers, and other circuit protection devices. (4) Connectors, including feed-through... connections. (7) Electrical splices. (8) Materials used to provide additional protection for wires, including...
Code of Federal Regulations, 2011 CFR
2011-01-01
... on electrical devices, including those on relays, interrupters, switches, contactors, terminal blocks and circuit breakers, and other circuit protection devices. (4) Connectors, including feed-through... connections. (7) Electrical splices. (8) Materials used to provide additional protection for wires, including...
NASA Astrophysics Data System (ADS)
Zhong, Z. H.; Tang, R. X.; Zhou, M.; Deng, X. H.; Pang, Y.; Paterson, W. R.; Giles, B. L.; Burch, J. L.; Tobert, R. B.; Ergun, R. E.; Khotyaintsev, Y. V.; Lindquist, P.-A.
2018-02-01
Secondary flux ropes are suggested to play important roles in energy dissipation and particle acceleration during magnetic reconnection. However, their generation mechanism is not fully understood. In this Letter, we present the first direct evidence that a secondary flux rope was generated due to the evolution of an electron vortex, which was driven by the electron Kelvin-Helmholtz instability in an ion diffusion region as observed by the Magnetospheric Multiscale mission. The subion scale (less than the ion inertial length) flux rope was embedded within the electron vortex, which contained a secondary electron diffusion region at the trailing edge of the flux rope. We propose that intense electron shear flow produced by reconnection generated the electron Kelvin-Helmholtz vortex, which induced a secondary reconnection in the exhaust of the primary X line and then led to the formation of the flux rope. This result strongly suggests that secondary electron Kelvin-Helmholtz instability is important for reconnection dynamics.
Zhong, Z H; Tang, R X; Zhou, M; Deng, X H; Pang, Y; Paterson, W R; Giles, B L; Burch, J L; Tobert, R B; Ergun, R E; Khotyaintsev, Y V; Lindquist, P-A
2018-02-16
Secondary flux ropes are suggested to play important roles in energy dissipation and particle acceleration during magnetic reconnection. However, their generation mechanism is not fully understood. In this Letter, we present the first direct evidence that a secondary flux rope was generated due to the evolution of an electron vortex, which was driven by the electron Kelvin-Helmholtz instability in an ion diffusion region as observed by the Magnetospheric Multiscale mission. The subion scale (less than the ion inertial length) flux rope was embedded within the electron vortex, which contained a secondary electron diffusion region at the trailing edge of the flux rope. We propose that intense electron shear flow produced by reconnection generated the electron Kelvin-Helmholtz vortex, which induced a secondary reconnection in the exhaust of the primary X line and then led to the formation of the flux rope. This result strongly suggests that secondary electron Kelvin-Helmholtz instability is important for reconnection dynamics.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oz, E.; Myers, C. E.; Yamada, M.
2011-07-19
The stability properties of partial toroidal flux ropes are studied in detail in the laboratory, motivated by ubiquitous arched magnetic structures found on the solar surface. The flux ropes studied here are magnetized arc discharges formed between two electrodes in the Magnetic Reconnection Experiment (MRX) [Yamada et al., Phys. Plasmas, 4, 1936 (1997)]. The three dimensional evolution of these flux ropes is monitored by a fast visible light framing camera, while their magnetic structure is measured by a variety of internal magnetic probes. The flux ropes are consistently observed to undergo large-scale oscillations as a result of an external kinkmore » instability. Using detailed scans of the plasma current, the guide field strength, and the length of the flux rope, we show that the threshold for kink stability is governed by the Kruskal-Shafranov limit for a flux rope that is held fixed at both ends (i.e., qa = 1).« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oz, E.; Myers, C. E.; Yamada, M.
2011-10-15
The stability properties of partial-toroidal flux ropes are studied in detail in the laboratory, motivated by ubiquitous arched magnetic structures found on the solar surface. The flux ropes studied here are magnetized arc discharges formed between two electrodes in the Magnetic Reconnection Experiment (MRX) [Yamada et al., Phys. Plasmas 4, 1936 (1997)]. The three dimensional evolution of these flux ropes is monitored by a fast visible light framing camera, while their magnetic structure is measured by a variety of internal magnetic probes. The flux ropes are consistently observed to undergo large-scale oscillations as a result of an external kink instability.more » Using detailed scans of the plasma current, the guide field strength, and the length of the flux rope, we show that the threshold for kink stability is governed by the Kruskal-Shafranov limit for a flux rope that is held fixed at both ends (i.e., q{sub a} = 1).« less
Reusable Hot-Wire Cable Cutter
NASA Technical Reports Server (NTRS)
Pauken, Michael T.; Steinkraus, Joel M.
2010-01-01
During the early development stage of balloon deployment systems for missions, nichrome wire cable cutters were often used in place of pyro-actuated cutters. Typically, a nichrome wire is wrapped around a bundle of polymer cables with a low melting point and connected to a relay-actuated electric circuit. The heat from the nichrome reduces the strength of the cable bundle, which quickly breaks under a mechanical load and can thus be used as a release mechanism for a deployment system. However, the use of hand-made heated nichrome wire for cutters is not very reliable. Often, the wrapped nichrome wire does not cut through the cable because it either pulls away from its power source or does not stay in contact with the cable being cut. Because nichrome is not readily soldered to copper wire, unreliable mechanical crimps are often made to connect the nichrome to an electric circuit. A self-contained device that is reusable and reliable was developed to sever cables for device release or deployment. The nichrome wire in this new device is housed within an enclosure to prevent it from being damaged by handling. The electric power leads are internally connected within the unit to the nichrome wire using a screw terminal connection. A bayonet plug, a quick and secure method of connecting the cutter to the power source, is used to connect the cutter to the power leads similar to those used in pyro-cutter devices. A small ceramic tube [0.25-in. wide 0.5-in. long (.6.4-mm wide 13-mm long)] houses a spiraled nichrome wire that is heated when a cable release action is required. The wire is formed into a spiral coil by wrapping it around a mandrel. It is then laid inside the ceramic tube so that it fits closely to the inner surface of the tube. The ceramic tube provides some thermal and electrical insulation so that most of the heat generated by the wire is directed toward the cable bundle in the center of the spiral. The ceramic tube is cemented into an aluminum block, which holds it in position. The leads of the nichrome wire are attached to screw terminals that connect them to power leads. A bayonet plug mounted at the bottom of the rectangular block connects the power leads to a relay circuit. A thin aluminum shell encloses the entire structure, leaving access points to attach to the bayonet plug and to feed a cable into the cylinder. The access holes for the deployment cable are a smaller diameter than the nichrome coil to prevent the cable from coming in direct contact with the nichrome when loaded. It uses the same general method of severing a cable with a heated wire as was used previously, but implements it in such a way that it is more reliable and less prone to failure. It creates a mechanism to create repeatability that was nonexistent in the previous method.
PROMINENCE FORMATION ASSOCIATED WITH AN EMERGING HELICAL FLUX ROPE
DOE Office of Scientific and Technical Information (OSTI.GOV)
Okamoto, Takenori J.; Tsuneta, Saku; Katsukawa, Yukio
2009-05-20
The formation and evolution process and magnetic configuration of solar prominences remain unclear. In order to study the formation process of prominences, we examine continuous observations of a prominence in NOAA AR 10953 with the Solar Optical Telescope on the Hinode satellite. As reported in our previous Letter, we find a signature suggesting that a helical flux rope emerges from below the photosphere under a pre-existing prominence. Here we investigate more detailed properties and photospheric indications of the emerging helical flux rope, and discuss their relationship to the formation of the prominence. Our main conclusions are: (1) a dark regionmore » with absence of strong vertical magnetic fields broadens and then narrows in Ca II H-line filtergrams. This phenomenon is consistent with the emergence of the helical flux rope as photospheric counterparts. The size of the flux rope is roughly 30,000 km long and 10,000 km wide. The width is larger than that of the prominence. (2) No shear motion or converging flows are detected, but we find diverging flows such as mesogranules along the polarity inversion line. The presence of mesogranules may be related to the emergence of the helical flux rope. (3) The emerging helical flux rope reconnects with magnetic fields of the pre-existing prominence to stabilize the prominence for the next several days. We thus conjecture that prominence coronal magnetic fields emerge in the form of helical flux ropes that contribute to the formation and maintenance of the prominence.« less
NASA Astrophysics Data System (ADS)
le Roux, J. A.; Zank, G. P.; Webb, G. M.; Khabarova, O. V.
2016-08-01
Computational and observational evidence is accruing that heliospheric shocks, as emitters of vorticity, can produce downstream magnetic flux ropes and filaments. This led Zank et al. to investigate a new paradigm whereby energetic particle acceleration near shocks is a combination of diffusive shock acceleration (DSA) with downstream acceleration by many small-scale contracting and reconnecting (merging) flux ropes. Using a model where flux-rope acceleration involves a first-order Fermi mechanism due to the mean compression of numerous contracting flux ropes, Zank et al. provide theoretical support for observations that power-law spectra of energetic particles downstream of heliospheric shocks can be harder than predicted by DSA theory and that energetic particle intensities should peak behind shocks instead of at shocks as predicted by DSA theory. In this paper, a more extended formalism of kinetic transport theory developed by le Roux et al. is used to further explore this paradigm. We describe how second-order Fermi acceleration, related to the variance in the electromagnetic fields produced by downstream small-scale flux-rope dynamics, modifies the standard DSA model. The results show that (I) this approach can qualitatively reproduce observations of particle intensities peaking behind the shock, thus providing further support for the new paradigm, and (II) stochastic acceleration by compressible flux ropes tends to be more efficient than incompressible flux ropes behind shocks in modifying the DSA spectrum of energetic particles.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Le Roux, J. A.; Zank, G. P.; Webb, G. M.
2016-08-10
Computational and observational evidence is accruing that heliospheric shocks, as emitters of vorticity, can produce downstream magnetic flux ropes and filaments. This led Zank et al. to investigate a new paradigm whereby energetic particle acceleration near shocks is a combination of diffusive shock acceleration (DSA) with downstream acceleration by many small-scale contracting and reconnecting (merging) flux ropes. Using a model where flux-rope acceleration involves a first-order Fermi mechanism due to the mean compression of numerous contracting flux ropes, Zank et al. provide theoretical support for observations that power-law spectra of energetic particles downstream of heliospheric shocks can be harder thanmore » predicted by DSA theory and that energetic particle intensities should peak behind shocks instead of at shocks as predicted by DSA theory. In this paper, a more extended formalism of kinetic transport theory developed by le Roux et al. is used to further explore this paradigm. We describe how second-order Fermi acceleration, related to the variance in the electromagnetic fields produced by downstream small-scale flux-rope dynamics, modifies the standard DSA model. The results show that (i) this approach can qualitatively reproduce observations of particle intensities peaking behind the shock, thus providing further support for the new paradigm, and (ii) stochastic acceleration by compressible flux ropes tends to be more efficient than incompressible flux ropes behind shocks in modifying the DSA spectrum of energetic particles.« less
Three-dimensional prominence-hosting magnetic configurations: Creating a helical magnetic flux rope
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xia, C.; Keppens, R.; Guo, Y.
2014-01-10
The magnetic configuration hosting prominences and their surrounding coronal structure is a key research topic in solar physics. Recent theoretical and observational studies strongly suggest that a helical magnetic flux rope is an essential ingredient to fulfill most of the theoretical and observational requirements for hosting prominences. To understand flux rope formation details and obtain magnetic configurations suitable for future prominence formation studies, we here report on three-dimensional isothermal magnetohydrodynamic simulations including finite gas pressure and gravity. Starting from a magnetohydrostatic corona with a linear force-free bipolar magnetic field, we follow its evolution when introducing vortex flows around the mainmore » polarities and converging flows toward the polarity inversion line near the bottom of the corona. The converging flows bring the feet of different loops together at the polarity inversion line, where magnetic reconnection and flux cancellation happen. Inflow and outflow signatures of the magnetic reconnection process are identified, and thereby the newly formed helical loops wind around preexisting ones so that a complete flux rope grows and ascends. When a macroscopic flux rope is formed, we switch off the driving flows and find that the system relaxes to a stable state containing a helical magnetic flux rope embedded in an overlying arcade structure. A major part of the formed flux rope is threaded by dipped field lines that can stably support prominence matter, while the total mass of the flux rope is in the order of 4-5× 10{sup 14} g.« less
Asymmetric Differential Resistance of Current Biased Mesoscopic AuFe Wires
NASA Astrophysics Data System (ADS)
Eom, J.; Chandrasekhar, V.; Neuttiens, G.; Strunk, C.; van Haesendonck, C.; Bruynseraede, Y.
1996-03-01
An anomalous asymmetry is found in the differential resistance dV/dI of mesoscopic AuFe wires as a function of dc bias current at low temperatures. The samples are fabricated by ion implanting Au wires of length 1.0 - 35.0 μ m and of width 0.1 - 1.0 μ m with Fe at two different concentrations, 0.2 at.% and 0.4 at.%. The asymmetry is more pronounced in narrow and short samples. The asymmetric component of dV/dI increases with decreasing temperature, and saturates below the maximum in the spin glass resistance. It is found that the lead configuration for the four-terminal measurement also affects the asymmetric component of dV/dI.
NASA Astrophysics Data System (ADS)
Moor, Andreas; Volkov, Anatoly F.; Efetov, Konstantin B.
2016-03-01
On the basis of the Usadel equation we study a multiterminal Josephson junction. This junction is composed by "magnetic" superconductors Sm, which have singlet pairing and are separated from the normal n wire by spin filters so that the Josephson coupling is caused only by fully polarized triplet components. We show that there is no interaction between triplet Cooper pairs with antiparallel total spin orientations. The presence of an additional singlet superconductor S attached to the n wire leads to a finite Josephson current IQ with an unusual current-phase relation. The density of states in the n wire for different orientations of spins of Cooper pairs is calculated. We derive a general formula for the current IQ in a multiterminal Josephson contact and apply this formula for analysis of two four-terminal Josephson junctions of different structures. It is shown in particular that both the "nematic" and the "magnetic" cases can be realized in these junctions. In a two-terminal structure with parallel filter orientations and in a three-terminal structure with antiparallel filter orientations of the "magnetic" superconductors with attached additional singlet superconductor, we find a nonmonotonic temperature dependence of the critical current. Also, in these structures, the critical current shows a Riedel peak like dependence on the exchange field in the "magnetic" superconductors. Although there is no current through the S/n interface due to orthogonality of the singlet and triplet components, the phase of the order parameter in the superconuctor S is shown to affect the Josephson current in a multiterminal structure.
NASA Astrophysics Data System (ADS)
Li, Mo; Wu, Jian; Lu, Yihan; Li, Xingwen; Li, Yang; Qiu, Mengtong
2018-01-01
Tungsten wire explosion is very asymmetric when fast current rate and insulated coatings are both applied on negative discharge facility using a 24-mm-diameter cathode geometry, which is commonly used on mega-ampere facilities. It is inferred, based on an analytical treatment of the guiding center drift and COMSOL simulations, that the large negative radial electric field causes early voltage breakdown and terminates energy deposition into the wire core on the anode side of the wire. After the anode side is short circuited, the radial electric field along the wire surface on the cathode side will change its polarity and thus leading to additional energy deposition into the wire core. This change causes ˜10 times larger energy deposition and ˜14 times faster explosion velocity in the cathode side than the anode side. In order to reduce this asymmetry, a hollow cylindrical cathode geometry was used to reverse the polarity of radial electric field and was optimized to use on multi-MA facilities. In this case, fully vaporized polyimide-coated tungsten wire with great symmetry improvement was achieved with energy deposition of ˜8.8 eV/atom. The atomic and electronic density distributions for the two different load geometries were obtained by the double-wavelength measurement.
30 CFR 57.19019 - Guide ropes.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Guide ropes. 57.19019 Section 57.19019 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND... rope at installation shall meet the minimum value calculated as follows: Minimum value=Static Load×5.0. ...
NASA Astrophysics Data System (ADS)
Liu, Chen; Tang, Guang-Rui; Jiang, Ming; Dong, Yu-Ming
2017-09-01
According to the practical situation of stringing construction for Ultra High Voltage (UHV) overhead transmission line, construction technology standardization of primary guide rope laying by multi-rotor aircraft is studied. This paper mainly focuses on the construction preparation, test flight and technology of laying primary guide rope. The summary of the construction technology standardization of primary guide rope laying by multi-rotor aircraft in stringing construction are useful in further guiding practical construction of transmission line.
Vortex rope instabilities in a model of conical draft tube
NASA Astrophysics Data System (ADS)
Skripkin, Sergey; Tsoy, Mikhail; Kuibin, Pavel; Shtork, Sergey
2017-10-01
We report on experimental studies of the formation of vortex ropes in a laboratory simplified model of hydroturbine draft tube. Work is focused on the observation of various flow patterns at the different rotational speed of turbine runner at fixed flow rate. The measurements involve high-speed visualization and pressure pulsations recordings. Draft tube wall pressure pulsations are registered by pressure transducer for different flow regimes. Vortex rope precession frequency were calculated using FFT transform. The experiments showed interesting features of precessing vortex rope like twin spiral and formation of vortex ring.
GENESIS OF INTERPLANETARY INTERMITTENT TURBULENCE: A CASE STUDY OF ROPE–ROPE MAGNETIC RECONNECTION
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chian, Abraham C.-L.; Loew, Murray H.; Feng, Heng Q.
In a recent paper, the relation between current sheet, magnetic reconnection, and turbulence at the leading edge of an interplanetary coronal mass ejection was studied. We report here the observation of magnetic reconnection at the interface region of two interplanetary magnetic flux ropes. The front and rear boundary layers of three interplanetary magnetic flux ropes are identified, and the structures of magnetic flux ropes are reconstructed by the Grad–Shafranov method. A quantitative analysis of the reconnection condition and the degree of intermittency reveals that rope–rope magnetic reconnection is the most likely site for genesis of interplanetary intermittency turbulence in this event.more » The dynamic pressure pulse resulting from this reconnection triggers the onset of a geomagnetic storm.« less
Wu, Renyuan; Zhu, Zhencai; Cao, Guohua
2015-01-01
The behavior of rope-guided conveyances is so complicated that the rope-guided hoisting system hasn't been understood thoroughly so far. In this paper, with user-defined functions loaded, ANSYS FLUENT 14.5 was employed to simulate lateral motion of rope-guided conveyances in two typical kinds of shaft layouts. With rope-guided mine elevator and mine cages taken into account, results show that the lateral aerodynamic buffeting force is much larger than the Coriolis force, and the side aerodynamic force have the same order of magnitude as the Coriolis force. The lateral aerodynamic buffeting forces should also be considered especially when the conveyance moves along the ventilation air direction. The simulation shows that the closer size of the conveyances can weaken the transverse aerodynamic buffeting effect.
Studying the Formation and Evolution of Eruptive Solar Magnetic Flux Ropes
NASA Astrophysics Data System (ADS)
Linton, M.
2017-12-01
Solar magnetic eruptions are dramatic sources of solar activity, and dangerous sources of space weather hazards. Many of these eruptions take the form of magnetic flux ropes, i.e., magnetic fieldlines wrapping around a core magnetic flux tube. Investigating the processes which form these flux ropes both prior to and during eruption, and investigating their evolution after eruption, can give us a critical window into understanding the sources of and processes involved in these eruptions. This presentation will discuss modeling and observational investigations into these various phases of flux rope formation, eruption, and evolution, and will discuss how these different explorations can be used to develop a more complete picture of erupting flux rope dynamics. This work is funded by the NASA Living with a Star program.
Dynamic topology and flux rope evolution during non-linear tearing of 3D null point current sheets
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wyper, P. F., E-mail: peterw@maths.dundee.ac.uk; Pontin, D. I., E-mail: dpontin@maths.dundee.ac.uk
2014-10-15
In this work, the dynamic magnetic field within a tearing-unstable three-dimensional current sheet about a magnetic null point is described in detail. We focus on the evolution of the magnetic null points and flux ropes that are formed during the tearing process. Generally, we find that both magnetic structures are created prolifically within the layer and are non-trivially related. We examine how nulls are created and annihilated during bifurcation processes, and describe how they evolve within the current layer. The type of null bifurcation first observed is associated with the formation of pairs of flux ropes within the current layer.more » We also find that new nulls form within these flux ropes, both following internal reconnection and as adjacent flux ropes interact. The flux ropes exhibit a complex evolution, driven by a combination of ideal kinking and their interaction with the outflow jets from the main layer. The finite size of the unstable layer also allows us to consider the wider effects of flux rope generation. We find that the unstable current layer acts as a source of torsional magnetohydrodynamic waves and dynamic braiding of magnetic fields. The implications of these results to several areas of heliophysics are discussed.« less
Safety in the Automated Office.
ERIC Educational Resources Information Center
Graves, Pat R.; Greathouse, Lillian R.
1990-01-01
Office automation has introduced new hazards to the workplace: electrical hazards related to computer wiring, musculoskeletal problems resulting from use of computer terminals and design of work stations, and environmental concerns related to ventilation, noise levels, and office machine chemicals. (SK)
Handbook of estimating data, factors, and procedures. [for manufacturing cost studies
NASA Technical Reports Server (NTRS)
Freeman, L. M.
1977-01-01
Elements to be considered in estimating production costs are discussed in this manual. Guidelines, objectives, and methods for analyzing requirements and work structure are given. Time standards for specific specfic operations are listed for machining, sheet metal working, electroplating and metal treating; painting; silk screening, etching and encapsulating; coil winding; wire preparation and wiring; soldering; and the fabrication of etched circuits and terminal boards. The relation of the various elements of cost to the total cost as proposed for various programs by various contractors is compared with government estimates.
Effects of fishing rope strength on the severity of large whale entanglements.
Knowlton, Amy R; Robbins, Jooke; Landry, Scott; McKenna, Henry A; Kraus, Scott D; Werner, Timothy B
2016-04-01
Entanglement in fixed fishing gear affects whales worldwide. In the United States, deaths of North Atlantic right (Eubalaena glacialis) and humpback whales (Megaptera novaeangliae) have exceeded management limits for decades. We examined live and dead whales entangled in fishing gear along the U.S. East Coast and the Canadian Maritimes from 1994 to 2010. We recorded whale species, age, and injury severity and determined rope polymer type, breaking strength, and diameter of the fishing gear. For the 132 retrieved ropes from 70 cases, tested breaking strength range was 0.80-39.63 kN (kiloNewtons) and the mean was 11.64 kN (SD 8.29), which is 26% lower than strength at manufacture (range 2.89-53.38 kN, mean = 15.70 kN [9.89]). Median rope diameter was 9.5 mm. Right and humpback whales were found in ropes with significantly stronger breaking strengths at time of manufacture than minke whales (Balaenoptera acuturostrata) (19.30, 17.13, and 10.47 mean kN, respectively). Adult right whales were found in stronger ropes (mean 34.09 kN) than juvenile right whales (mean 15.33 kN) and than all humpback whale age classes (mean 17.37 kN). For right whales, severity of injuries increased since the mid 1980s, possibly due to changes in rope manufacturing in the mid 1990s that resulted in production of stronger ropes at the same diameter. Our results suggest that broad adoption of ropes with breaking strengths of ≤ 7.56 kN (≤ 1700 lbsf) could reduce the number of life-threatening entanglements for large whales by at least 72%, and yet could provide sufficient strength to withstand the routine forces involved in many fishing operations. A reduction of this magnitude would achieve nearly all the mitigation legally required for U.S. stocks of North Atlantic right and humpback whales. Ropes with reduced breaking strength should be developed and tested to determine the feasibility of their use in a variety of fisheries. © 2015 The Authors. Conservation Biology published by Wiley Periodicals, Inc. on behalf of Society for Conservation Biology.
A model for heliospheric flux-ropes
NASA Astrophysics Data System (ADS)
Nieves-Chinchilla, T.; Linton, M.; Vourlidas, A.; Hidalgo, M. A. U.
2017-12-01
This work is presents an analytical flux-rope model, which explores different levels of complexity starting from a circular-cylindrical geometry. The framework of this series of models was established by Nieves-Chinchilla et al. 2016 with the circular-cylindrical analytical flux rope model. The model attempts to describe the magnetic flux rope topology with distorted cross-section as a possible consequence of the interaction with the solar wind. In this model, the flux rope is completely described in a non-orthogonal geometry. The Maxwell equations are solved using tensor calculus consistent with the geometry chosen, invariance along the axial direction, and with the assumption of no radial current density. The model is generalized in terms of the radial and azimuthal dependence of the poloidal current density component and axial current density component. The misalignment between current density and magnetic field is studied in detail for several example profiles of the axial and poloidal current density components. This theoretical analysis provides a map of the force distribution inside of the flux-rope. For reconstruction of the heliospheric flux-ropes, the circular-cylindrical reconstruction technique has been adapted to the new geometry and applied to in situ ICMEs with a flux-rope entrained and tested with cases with clear in situ signatures of distortion. The model adds a piece in the puzzle of the physical-analytical representation of these magnetic structures that should be evaluated with the ultimate goal of reconciling in-situ reconstructions with imaging 3D remote sensing CME reconstructions. Other effects such as axial curvature and/or expansion could be incorporated in the future to fully understand the magnetic structure.
Regularized Biot–Savart Laws for Modeling Magnetic Flux Ropes
NASA Astrophysics Data System (ADS)
Titov, Viacheslav S.; Downs, Cooper; Mikić, Zoran; Török, Tibor; Linker, Jon A.; Caplan, Ronald M.
2018-01-01
Many existing models assume that magnetic flux ropes play a key role in solar flares and coronal mass ejections (CMEs). It is therefore important to develop efficient methods for constructing flux-rope configurations constrained by observed magnetic data and the morphology of the pre-eruptive source region. For this purpose, we have derived and implemented a compact analytical form that represents the magnetic field of a thin flux rope with an axis of arbitrary shape and circular cross-sections. This form implies that the flux rope carries axial current I and axial flux F, so that the respective magnetic field is the curl of the sum of axial and azimuthal vector potentials proportional to I and F, respectively. We expressed the vector potentials in terms of modified Biot–Savart laws, whose kernels are regularized at the axis in such a way that, when the axis is straight, these laws define a cylindrical force-free flux rope with a parabolic profile for the axial current density. For the cases we have studied so far, we determined the shape of the rope axis by following the polarity inversion line of the eruptions’ source region, using observed magnetograms. The height variation along the axis and other flux-rope parameters are estimated by means of potential-field extrapolations. Using this heuristic approach, we were able to construct pre-eruption configurations for the 2009 February 13 and 2011 October 1 CME events. These applications demonstrate the flexibility and efficiency of our new method for energizing pre-eruptive configurations in simulations of CMEs.
Forward Modeling of Coronal Mass Ejection Flux Ropes in the Inner Heliosphere with 3DCORE.
Möstl, C; Amerstorfer, T; Palmerio, E; Isavnin, A; Farrugia, C J; Lowder, C; Winslow, R M; Donnerer, J M; Kilpua, E K J; Boakes, P D
2018-03-01
Forecasting the geomagnetic effects of solar storms, known as coronal mass ejections (CMEs), is currently severely limited by our inability to predict the magnetic field configuration in the CME magnetic core and by observational effects of a single spacecraft trajectory through its 3-D structure. CME magnetic flux ropes can lead to continuous forcing of the energy input to the Earth's magnetosphere by strong and steady southward-pointing magnetic fields. Here we demonstrate in a proof-of-concept way a new approach to predict the southward field B z in a CME flux rope. It combines a novel semiempirical model of CME flux rope magnetic fields (Three-Dimensional Coronal ROpe Ejection) with solar observations and in situ magnetic field data from along the Sun-Earth line. These are provided here by the MESSENGER spacecraft for a CME event on 9-13 July 2013. Three-Dimensional Coronal ROpe Ejection is the first such model that contains the interplanetary propagation and evolution of a 3-D flux rope magnetic field, the observation by a synthetic spacecraft, and the prediction of an index of geomagnetic activity. A counterclockwise rotation of the left-handed erupting CME flux rope in the corona of 30° and a deflection angle of 20° is evident from comparison of solar and coronal observations. The calculated Dst matches reasonably the observed Dst minimum and its time evolution, but the results are highly sensitive to the CME axis orientation. We discuss assumptions and limitations of the method prototype and its potential for real time space weather forecasting and heliospheric data interpretation.
Bin Abd Razak, Hamid Rahmatullah; Yeo, Eng-Meng Nicholas; Yeo, William; Lie, Tijauw-Tjoen Denny
2018-07-01
The aim of this study was to compare the short-term outcomes of arthroscopic TightRope ® fixation with that of hook plate fixation in patients with acute unstable acromioclavicular joint dislocations. We conducted a prospective case-control study of twenty-six patients with an acute ACJ dislocation who underwent surgical repair with either an arthroscopic TightRope ® fixation or a hook plate from 2013 to 2016. Clinical and radiological data were collected prospectively. Clinical outcomes were evaluated using the Constant Score, the University of California at Los Angeles (UCLA) Shoulder Score, Oxford Shoulder Score as well as the visual analogue scale. Radiological outcomes were assessed with the coracoclavicular distance (CCD). Sixteen patients underwent arthroscopic TightRope ® fixation, while 10 patients underwent hook plate fixation. There were no significant differences in the preoperative variables except for the mean UCLA 4b infraspinatus score (TightRope ® 2.8 vs. hook plate 3.8; p = 0.030). Duration of surgery was significantly longer in the TightRope ® group. At 1 year post-operatively, the TightRope ® group had a significantly better Constant Score and CCD with no complications. All patients with hook plate fixation had to undergo a second procedure for removal of implant, and 3 patients had complications. Arthroscopic TightRope ® fixation is a good option for the treatment of acute unstable ACJ dislocations. It has better short-term clinical and radiological outcomes as well as lesser complications when compared to hook plate fixation. Therapeutic, Level III.
Forward Modeling of Coronal Mass Ejection Flux Ropes in the Inner Heliosphere with 3DCORE
NASA Astrophysics Data System (ADS)
Möstl, C.; Amerstorfer, T.; Palmerio, E.; Isavnin, A.; Farrugia, C. J.; Lowder, C.; Winslow, R. M.; Donnerer, J. M.; Kilpua, E. K. J.; Boakes, P. D.
2018-03-01
Forecasting the geomagnetic effects of solar storms, known as coronal mass ejections (CMEs), is currently severely limited by our inability to predict the magnetic field configuration in the CME magnetic core and by observational effects of a single spacecraft trajectory through its 3-D structure. CME magnetic flux ropes can lead to continuous forcing of the energy input to the Earth's magnetosphere by strong and steady southward-pointing magnetic fields. Here we demonstrate in a proof-of-concept way a new approach to predict the southward field Bz in a CME flux rope. It combines a novel semiempirical model of CME flux rope magnetic fields (Three-Dimensional Coronal ROpe Ejection) with solar observations and in situ magnetic field data from along the Sun-Earth line. These are provided here by the MESSENGER spacecraft for a CME event on 9-13 July 2013. Three-Dimensional Coronal ROpe Ejection is the first such model that contains the interplanetary propagation and evolution of a 3-D flux rope magnetic field, the observation by a synthetic spacecraft, and the prediction of an index of geomagnetic activity. A counterclockwise rotation of the left-handed erupting CME flux rope in the corona of 30° and a deflection angle of 20° is evident from comparison of solar and coronal observations. The calculated Dst matches reasonably the observed Dst minimum and its time evolution, but the results are highly sensitive to the CME axis orientation. We discuss assumptions and limitations of the method prototype and its potential for real time space weather forecasting and heliospheric data interpretation.
The Application of Ultrasonic Inspection to Crimped Electrical Connections
NASA Technical Reports Server (NTRS)
Cramer, K. Elliott; Perey, Daniel F.; Yost, William T.
2010-01-01
The development of a new ultrasonic measurement technique to quantitatively assess wire crimp terminations is discussed. The development of a prototype instrument, based on a modified, commercially available, crimp tool, is demonstrated for applying this technique when wire crimps are installed. The crimp tool has three separate crimping locations that accommodate the three different ferrule diameters. The crimp tool in this study is capable of crimping wire diameters ranging from 12 to 26 American Wire Gauge (AWG). A transducer design is presented that allows for interrogation of each of the three crimp locations on the crimp tool without reconfiguring the device. An analysis methodology, based on transmitted ultrasonic energy and timing of the first received pulse is shown to correlate to both crimp location in the tool and the AWG of the crimp/ferrule combination. The detectability of a number of the crimp failure pathologies, such as missing strands, partially inserted wires and incomplete crimp compression, is discussed. A wave propagation model, solved by finite element analysis, describes the compressional ultrasonic wave propagation through the junction during the crimping process.
Subcutaneous electrode structure
NASA Technical Reports Server (NTRS)
Lund, G. F. (Inventor)
1980-01-01
A subcutaneous electrode structure suitable for a chronic implant and for taking a low noise electrocardiogram of an active animal, comprises a thin inflexible, smooth disc of stainless steel having a diameter as of 5 to 30 mm, which is sutured in place to the animal being monitored. The disc electrode includes a radially directed slot extending in from the periphery of the disc for approximately 1/3 of the diameter. Electrical connection is made to the disc by means of a flexible lead wire that extends longitudinally of the slot and is woven through apertures in the disc and held at the terminal end by means of a spot welded tab. Within the slot, an electrically insulative sleeve, such as silicone rubber, is placed over the wire. The wire with the sleeve mounted thereon is captured in the plane of the disc and within the slot by means of crimping tabs extending laterally of the slot and over the insulative wire. The marginal lip of the slot area is apertured and an electrically insulative potting material such as silicone rubber, is potted in place overlaying the wire slot region and through the apertures.
Helicity transformation under the collision and merging of two magnetic flux ropes
NASA Astrophysics Data System (ADS)
DeHaas, Timothy; Gekelman, Walter
2017-07-01
Magnetic helicity has become a useful tool in the analysis of astrophysical plasmas. Its conservation in the magnetohydrodynamic limit (and other fluid approaches) constrains the global behavior of large plasma structures. One such astrophysical structure is a magnetic flux rope: a tube-like, current-carrying plasma embedded in an external magnetic field. Bundles of these ropes are commonly observed in the near-earth environment and solar atmosphere. In this well-diagnosed experiment (three-dimensional measurements of ne, Te, Vp, B, J, E, and uflow), two magnetic flux ropes are generated in the Large Plasma Device at UCLA. These ropes are driven kink-unstable to trigger complex motion. As they interact, helicity conservation is examined in regions of reconnection. We examine (1) the transport of helicity and (2) the dissipation of the helicity. As the ropes move and the topology of the field lines diverge, a quasi-separatrix layer (QSL) is formed. As the QSL forms, magnetic helicity is dissipated within this region. At the same time, there is an influx of canonical helicity into the region such that the temporal derivative of magnetic helicity is zero.