A wireless PDA-based physiological monitoring system for patient transport.
Lin, Yuan-Hsiang; Jan, I-Chien; Ko, Patrick Chow-In; Chen, Yen-Yu; Wong, Jau-Min; Jan, Gwo-Jen
2004-12-01
This paper proposes a mobile patient monitoring system, which integrates current personal digital assistant (PDA) technology and wireless local area network (WLAN) technology. At the patient's location, a wireless PDA-based monitor is used to acquire continuously the patient's vital signs, including heart rate, three-lead electrocardiography, and SpO2. Through the WLAN, the patient's biosignals can be transmitted in real-time to a remote central management unit, and authorized medical staffs can access the data and the case history of the patient, either by the central management unit or the wireless devices. A prototype of this system has been developed and implemented. The system has been evaluated by technical verification, clinical test, and user survey. The evaluation of performance yields a high degree of satisfaction (mean = 4.64, standard deviation--SD = 0.53 in a five-point Likert scale) of users who used the PDA-based system for intrahospital transport. The results also show that the wireless PDA model is superior to the currently used monitors both in mobility and in usability, and is, therefore, better suited to patient transport.
Environmental implications of wireless technologies: news delivery and business meetings.
Toffel, Michael W; Horvath, Arpad
2004-06-01
Wireless information technologies are providing new ways to communicate, and are one of several information and communication technologies touted as an opportunity to reduce society's overall environmental impacts. However, rigorous system-wide environmental impact comparisons of these technologies to the traditional applications they may replace have only recently been initiated, and the results have been mixed. In this paper, the environmental effects of two applications of wireless technologies are compared to those of conventional technologies for which they can substitute. First, reading newspaper content on a personal digital assistant (PDA) is compared to the traditional way of reading a newspaper. Second, wireless teleconferencing is compared to business travel. The results show that for both comparisons wireless technologies create lower environmental impacts. Compared to reading a newspaper, receiving the news on a PDA wirelessly results in the release of 32-140 times less CO2, several orders of magnitude less NOx and SOx, and the use of 26-67 times less water. Wireless teleconferencing results in 1-3 orders of magnitude lower CO2, NOx, and SO2 emissions than business travel.
Garrett, Bernard Mark; Jackson, Cathryn
2006-12-01
This paper outlines the development and evaluation of a wireless personal digital assistant (PDA) based clinical learning tool designed to promote professional reflection for health professionals. The "Clinical e-portfolio" was developed at the University of British Columbia School of Nursing to enable students immediately to access clinical expertise and resources remotely, and record their clinical experiences in a variety of media (text, audio and images). The PDA e-portfolio tool was developed to demonstrate the potential use of mobile networked technologies to support and improve clinical learning; promote reflective learning in practice; engage students in the process of knowledge translation; help contextualize and embed clinical knowledge whilst in the workplace; and to help prevent the isolation of students whilst engaged in supervised clinical practice. The mobile e-portfolio was developed to synchronise wirelessly with a user's personal Web based portfolio from any remote location where a cellular telephone signal or wireless (Wi-Fi) connection could be obtained. An evaluation of the tool was undertaken with nurse practitioner and medical students, revealing positive attitudes to the use of PDA based tools and portfolios, but limits to the use of the PDA portfolio due to the inherent interface restrictions of the PDA.
Programming Wireless Handheld Devices for Applications in Teaching Astronomy
NASA Astrophysics Data System (ADS)
Budiardja, R.; Saranathan, V.; Guidry, M.
2002-12-01
Wireless technology implemented with handheld devices has attractive features because of the potential to access large amounts of data and the prospect of on-the-fly computational analysis from a device that can be carried in a shirt pocket. We shall describe applications of such technology to the general paradigm of making digital wireless connections from the field to upload information and queries to network servers, executing (potentially complex) data analysis and/or database operations on fast network computers, and returning real-time information from this analysis to the handheld device in the field. As illustration, we shall describe several client/server programs that we have written for applications in teaching introductory astronomy. For example, one program allows static and dynamic properties of astronomical objects to be accessed in a remote observation laboratory setting using a digital cell phone or PDA. Another implements interactive quizzing over a cell phone or PDA using a 700-question introductory astronomy quiz database, thus permitting students to study for astronomy quizzes in any environment in which they have a few free minutes and a digital cell phone or wireless PDA. The presentation will include hands-on demonstrations with real devices.
A PDA study management tool (SMT) utilizing wireless broadband and full DICOM viewing capability
NASA Astrophysics Data System (ADS)
Documet, Jorge; Liu, Brent; Zhou, Zheng; Huang, H. K.; Documet, Luis
2007-03-01
During the last 4 years IPI (Image Processing and Informatics) Laboratory has been developing a web-based Study Management Tool (SMT) application that allows Radiologists, Film librarians and PACS-related (Picture Archiving and Communication System) users to dynamically and remotely perform Query/Retrieve operations in a PACS network. The users utilizing a regular PDA (Personal Digital Assistant) can remotely query a PACS archive to distribute any study to an existing DICOM (Digital Imaging and Communications in Medicine) node. This application which has proven to be convenient to manage the Study Workflow [1, 2] has been extended to include a DICOM viewing capability in the PDA. With this new feature, users can take a quick view of DICOM images providing them mobility and convenience at the same time. In addition, we are extending this application to Metropolitan-Area Wireless Broadband Networks. This feature requires Smart Phones that are capable of working as a PDA and have access to Broadband Wireless Services. With the extended application to wireless broadband technology and the preview of DICOM images, the Study Management Tool becomes an even more powerful tool for clinical workflow management.
A Wireless Physiological Signal Monitoring System with Integrated Bluetooth and WiFi Technologies.
Yu, Sung-Nien; Cheng, Jen-Chieh
2005-01-01
This paper proposes a wireless patient monitoring system which integrates Bluetooth and WiFi wireless technologies. A wireless portable multi-parameter device was designated to acquire physiological signals and transmit them to a local server via Bluetooth wireless technology. Four kinds of monitor units were designed to communicate via the WiFi wireless technology, including a local monitor unit, a control center, mobile devices (personal digital assistant; PDA), and a web page. The use of various monitor units is intending to meet different medical requirements for different medical personnel. This system was demonstrated to promote the mobility and flexibility for both the patients and the medical personnel, which further improves the quality of health care.
Wireless remote control clinical image workflow: utilizing a PDA for offsite distribution
NASA Astrophysics Data System (ADS)
Liu, Brent J.; Documet, Luis; Documet, Jorge; Huang, H. K.; Muldoon, Jean
2004-04-01
Last year we presented in RSNA an application to perform wireless remote control of PACS image distribution utilizing a handheld device such as a Personal Digital Assistant (PDA). This paper describes the clinical experiences including workflow scenarios of implementing the PDA application to route exams from the clinical PACS archive server to various locations for offsite distribution of clinical PACS exams. By utilizing this remote control application, radiologists can manage image workflow distribution with a single wireless handheld device without impacting their clinical workflow on diagnostic PACS workstations. A PDA application was designed and developed to perform DICOM Query and C-Move requests by a physician from a clinical PACS Archive to a CD-burning device for automatic burning of PACS data for the distribution to offsite. In addition, it was also used for convenient routing of historical PACS exams to the local web server, local workstations, and teleradiology systems. The application was evaluated by radiologists as well as other clinical staff who need to distribute PACS exams to offsite referring physician"s offices and offsite radiologists. An application for image workflow management utilizing wireless technology was implemented in a clinical environment and evaluated. A PDA application was successfully utilized to perform DICOM Query and C-Move requests from the clinical PACS archive to various offsite exam distribution devices. Clinical staff can utilize the PDA to manage image workflow and PACS exam distribution conveniently for offsite consultations by referring physicians and radiologists. This solution allows the radiologist to expand their effectiveness in health care delivery both within the radiology department as well as offisite by improving their clinical workflow.
Network of wireless gamma ray sensors for radiological detection and identification
NASA Astrophysics Data System (ADS)
Barzilov, A.; Womble, P.; Novikov, I.; Paschal, J.; Board, J.; Moss, K.
2007-04-01
The paper describes the design and development of a network of wireless gamma-ray sensors based on cell phone or WiFi technology. The system is intended for gamma-ray detection and automatic identification of radioactive isotopes and nuclear materials. The sensor is a gamma-ray spectrometer that uses wireless technology to distribute the results. A small-size sensor module contains a scintillation detector along with a small size data acquisition system, PDA, battery, and WiFi radio or a cell phone modem. The PDA with data acquisition and analysis software analyzes the accumulated spectrum on real-time basis and returns results to the screen reporting the isotopic composition and intensity of detected radiation source. The system has been programmed to mitigate false alarms from medical isotopes and naturally occurring radioactive materials. The decision-making software can be "trained" to indicate specific signatures of radiation sources like special nuclear materials. The sensor is supplied with GPS tracker coupling radiological information with geographical coordinates. The sensor is designed for easy use and rapid deployment in common wireless networks.
NASA Astrophysics Data System (ADS)
Budiardja, R. D.; Lingerfelt, E. J.; Guidry, M. W.
2003-05-01
Wireless technology implemented with handheld devices has attractive features because of the potential to access large amounts of data and the prospect of on-the-fly computational analysis from a device that can be carried in a shirt pocket. We shall describe applications of such technology to the general paradigm of making digital wireless connections from the field to upload information and queries to network servers, executing (potentially complex) programs and controlling data analysis and/or database operations on fast network computers, and returning real-time information from this analysis to the handheld device in the field. As illustration, we shall describe several client/server programs that we have written for applications in teaching introductory astronomy. For example, one program allows static and dynamic properties of astronomical objects to be accessed in a remote observation laboratory setting using a digital cell phone or PDA. Another implements interactive quizzing over a cell phone or PDA using a 700-question introductory astronomy quiz database, thus permitting students to study for astronomy quizzes in any environment in which they have a few free minutes and a digital cell phone or wireless PDA. Another allows one to control and monitor a computation done on a Beowulf cluster by changing the parameters of the computation remotely and retrieving the result when the computation is done. The presentation will include hands-on demonstrations with real devices. *Managed by UT-Battelle, LLC, for the U.S. Department of Energy under contract DE-AC05-00OR22725.
Implementing Wireless PDA Technology in the IT Curriculum
ERIC Educational Resources Information Center
Rawlinson, David R.; Bartel, Kimberlee
2006-01-01
Colleges and public universities must stay abreast of rapid changes in the application of information technology, typically on very limited budgets. Additionally, students increasingly expect faculty to apply bleeding-edge technology in the classroom and integrate it into the curriculum. This article briefly notes prevailing literature related to…
Duncan, R G; Shabot, M M
2000-01-01
TCP/IP and World-Wide-Web (WWW) technology have become the universal standards for networking and delivery of information. Personal digital assistants (PDAs), cellular telephones, and alphanumeric pagers are rapidly converging on a single pocket device that will leverage wireless TCP/IP networks and WWW protocols and can be used to deliver clinical information and alerts anytime, anywhere. We describe a wireless interface to clinical information for physicians based on Palm Corp.'s Palm VII pocket computer, a wireless digital network, encrypted data transmission, secure web servers, and a clinical data repository (CDR).
Duncan, R. G.; Shabot, M. M.
2000-01-01
TCP/IP and World-Wide-Web (WWW) technology have become the universal standards for networking and delivery of information. Personal digital assistants (PDAs), cellular telephones, and alphanumeric pagers are rapidly converging on a single pocket device that will leverage wireless TCP/IP networks and WWW protocols and can be used to deliver clinical information and alerts anytime, anywhere. We describe a wireless interface to clinical information for physicians based on Palm Corp.'s Palm VII pocket computer, a wireless digital network, encrypted data transmission, secure web servers, and a clinical data repository (CDR). PMID:11079875
Abayomi, A; Goodridge, W; Asika, O
2006-12-01
Biomedical and demographic data capture and the subsequent management of such information are critical factors in the implementation of any level of healthcare prevention and treatment program. The developing world is seriously handicapped by lack of infrastructure to acquire such data let alone manipulate the information banks for projections, forecasting and priority project planning. With this in mind we set about to use the recent proliferation of wireless cellular networks and easily accessible Personal Digital Assistants (PDA), to devise a means of collecting such data even from the most remote primary healthcare facility. Our priority is aimed at initially at providing a support technology for the HIV expanded program. This technology can be implemented in the absence of computerization and regular power supply. Utilizing a PDA to capture patient data (demographic, clinical and laboratory parameters), the healthcare giver can use a wireless link between the PDA and a cellular phone to transfer the data to a central medical data base. These can then become permanent and secure data banks for future use by health providers, either at the same location or at other health facility that have authorized access to the data bank. It also affords a platform for integrating reference labs into the network as well as the opportunity to disseminate continuing medical educational material. The network can also be adapted to electronic remote consultations and eventually its data banks can be assimilated into protocols of artificial intelligence and data mining.
Bluetooth wireless database for scoliosis clinics.
Lou, E; Fedorak, M V; Hill, D L; Raso, J V; Moreau, M J; Mahood, J K
2003-05-01
A database system with Bluetooth wireless connectivity has been developed so that scoliosis clinics can be run more efficiently and data can be mined for research studies without significant increases in equipment cost. The wireless database system consists of a Bluetooth-enabled laptop or PC and a Bluetooth-enabled handheld personal data assistant (PDA). Each patient has a profile in the database, which has all of his or her clinical history. Immediately prior to the examination, the orthopaedic surgeon selects a patient's profile from the database and uploads that data to the PDA over a Bluetooth wireless connection. The surgeon can view the entire clinical history of the patient while in the examination room and, at the same time, enter in any new measurements and comments from the current examination. After seeing the patient, the surgeon synchronises the newly entered information with the database wirelessly and prints a record for the chart. This combination of the database and the PDA both improves efficiency and accuracy and can save significant time, as there is less duplication of work, and no dictation is required. The equipment required to implement this solution is a Bluetooth-enabled PDA and a Bluetooth wireless transceiver for the PC or laptop.
Personal diabetes management system based on ubiquitous computing technology.
Park, Kyung-Soon; Kim, Nam-Jin; Hong, Joo-Hyun; Park, Mi-Sook; Cha, Eun-Jung; Lee, Tae-Soo
2006-01-01
Assisting diabetes patients to self manage blood glucose test and insulin injection is of great importance for their healthcare. This study presented a PDA based system to manage the personal glucose level data interfaced with a small glucometer through a serial port. The data stored in the PDA can be transmitted by cradle or wireless communication to the remote web-server, where further medical analysis and service is provided. This system enables more efficient and systematic management of diabetes patients through self management and remote medical practice.
Portable emergency telemedicine system over wireless broadband and 3G networks.
Hong, SungHye; Kim, SangYong; Kim, JungChae; Lim, DongKyu; Jung, SeokMyung; Kim, DongKeun; Yoo, Sun K
2009-01-01
The telemedicine system aims at monitoring patients remotely without limit in time and space. However the existing telemedicine systems exchange medical information simply in a specified location. Due to increasing speed in processing data and expanding bandwidth of wireless networks, it is possible to perform telemedicine services on personal digital assistants (PDA). In this paper, a telemedicine system on PDA was developed using wideband mobile networks such as Wi-Fi, HSDPA, and WiBro for high speed bandwidths. This system enables to utilize and exchange variety and reliable patient information of video, biosignals, chatting messages, and triage data. By measuring bandwidths of individual data of the system over wireless networks, and evaluating the performance of this system using PDA, we demonstrated the feasibility of the designed portable emergency telemedicine system.
Forsell, M; Häggström, M; Johansson, O; Sjögren, P
2008-11-08
To develop a personal digital assistant (PDA) application for oral health assessment fieldwork, including back-office and database systems (MobilDent). System design, construction and implementation of PDA, back-office and database systems. System requirements for MobilDent were collected, analysed and translated into system functions. User interfaces were implemented and system architecture was outlined. MobilDent was based on a platform with. NET (Microsoft) components, using an SQL Server 2005 (Microsoft) for data storage with Windows Mobile (Microsoft) operating system. The PDA devices were Dell Axim. System functions and user interfaces were specified for MobilDent. User interfaces for PDA, back-office and database systems were based on. NET programming. The PDA user interface was based on Windows suitable to a PDA display, whereas the back-office interface was designed for a normal-sized computer screen. A synchronisation module (MS Active Sync, Microsoft) was used to enable download of field data from PDA to the database. MobilDent is a feasible application for oral health assessment fieldwork, and the oral health assessment database may prove a valuable source for care planning, educational and research purposes. Further development of the MobilDent system will include wireless connectivity with download-on-demand technology.
PalmCIS: A Wireless Handheld Application for Satisfying Clinician Information Needs
Chen, Elizabeth S.; Mendonça, Eneida A.; McKnight, Lawrence K.; Stetson, Peter D.; Lei, Jianbo; Cimino, James J.
2004-01-01
Wireless handheld technology provides new ways to deliver and present information. As with any technology, its unique features must be taken into consideration and its applications designed accordingly. In the clinical setting, availability of needed information can be crucial during the decision-making process. Preliminary studies performed at New York Presbyterian Hospital (NYPH) determined that there are inadequate access to information and ineffective communication among clinicians (potential proximal causes of medical errors). In response to these findings, the authors have been developing extensions to their Web-based clinical information system including PalmCIS, an application that provides access to needed patient information via a wireless personal digital assistant (PDA). The focus was on achieving end-to-end security and developing a highly usable system. This report discusses the motivation behind PalmCIS, design and development of the system, and future directions. PMID:14527976
WIH-based IEEE 802.11 ECG monitoring implementation.
Moein, A; Pouladian, M
2007-01-01
New wireless technologies make possible the implementation of high level integration wireless devices which allow the replacement of traditional large wired monitoring devices. It offers new functionalities to physicians and will reduce the costs. Among these functionalities, biomedical signals can be sent to other devices (PDA, PC . . . ) or processing centers, without restricting the patients' mobility. This article discusses the WIH (Ward-In-Hand) structure and the software required for its implementation before an operational example is presented with its results. The aim of this project is the development and implementation of a reduced size electrocardiograph based on IEEE 802.11 with high speed and more accuracy, which allows wireless monitoring of patients, and the insertion of the information into the Wi-Fi hospital networks.
Communication protocol in chassis detecting wireless transmission system based on WiFi
USDA-ARS?s Scientific Manuscript database
In chassis detecting wireless transmission system, the wireless network communication protocol plays a key role in the information exchange and synchronization between the host and chassis PDA. This paper presents a wireless network transmission protocol based on TCP/IP which makes the rules of info...
Adusumilli, Sri Raj; Tobin, Jonathan N; Younge, Richard G; Kendall, Mat; Kukafka, Rita; Khan, Sharib; Chang, Otto; Mahabir, Kasandra
2006-01-01
The New York City Department of Health and Mental Hygiene, The Community Health Care Association of New York State and Clinical Directors Network are collaborating on the "eClinician Project," which has distributed seven hundred public health-friendly, wireless (WiFi) enabled Personal Digital Assistants (PDAs) to primary care clinicians working in New York City, federally funded, Community Health Centers (CHC) which serve minority underserved communities that suffer a disproportionate burden of chronic disease and lack access to health promotion disease prevention services. Each participating health center also received a wireless router to create an onsite internet hot spot to enable clinicians to have internet access. The goals of the eClinician Project are to: 1) To encourage adoption of information technology among providers in Community Health Centers in New York City by providing PDAs as a first line strategy towards achieving this goal, 2) enhance access to information on emergency preparedness, 3) improve patient outcomes by providing PDA-based clinical decision-support tools that support evidence-based care, 4) encourage chronic care management and health promotion/disease prevention activities, and 5) increase productivity and efficiency. CHC clinicians have received a hands-on, on-site orientation to PDAs. Ongoing training has continued via online CME-accredited webcasts (see www.CDNetwork.org). Clinical decision-support tools are available for download via the eClinician project web portal (see www.eClinician.org ). Public health alerts can be delivered to the PDAs or to the clinicians' desktop computers. Pre and post training surveys, in addition to a case study, have been used to evaluate the population demographics, PDA adoption by the clinicians, clinician attitudes towards using PDAs, PDA influence on clinical-decision making and barriers to adoption of PDAs and information technology in general.
Potential for Personal Digital Assistant interference with implantable cardiac devices.
Tri, Jeffrey L; Trusty, Jane M; Hayes, David L
2004-12-01
To determine whether the wireless local area network (WLAN) technology, specifically the Personal Digital Assistant (PDA), interferes with implantable cardiac pacemakers and defibrillators. Various pacemakers and defibrillators were tested in vitro at the Mayo Clinic in Rochester, Minn, between March 6 and July 30, 2003. These cardiac devices were exposed to an HP Compaq IPAQ PDA fitted with a Cisco Aironet WLAN card. Initial testing was designed to show whether the Aironet card radiated energy in a consistent pattern from the antenna of the PDA to ensure that subsequent cardiac device testing would not be affected by the orientation of the PDA to the cardiac device. Testing involved placing individual cardiac devices in a simulator and uniformly exposing each device at its most sensitive programmable value to the WLAN card set to maximum power. During testing with the Cisco WLAN Aironet card, all devices programmed to the unipolar or bipolar configuration single- or dual-chamber mode had normal pacing and sensing functions and exhibited no effects of electromagnetic interference except for 1 implantable cardioverter-defibrillator (ICD). This aberration was determined to relate to the design of the investigators' testing apparatus and not to the output of the PDA. The ICD device appropriately identified and labeled the electromagnetic aberration as "noise." We documented no electromagnetic interference caused by the WLAN technology by using in vitro testing of pacemakers and ICDs; however, testing ideally should be completed in vivo to confirm the lack of any clinically important interactions.
The use of a personal digital assistant for wireless entry of data into a database via the Internet.
Fowler, D L; Hogle, N J; Martini, F; Roh, M S
2002-01-01
Researchers typically record data on a worksheet and at some later time enter it into the database. Wireless data entry and retrieval using a personal digital assistant (PDA) at the site of patient contact can simplify this process and improve efficiency. A surgeon and a nurse coordinator provided the content for the database. The computer programmer created the database, placed the pages of the database on the PDA screen, and researched and installed security measures. Designing the database took 6 months. Meeting Health Insurance Portability and Accountability Act of 1996 (HIPAA) requirements for patient confidentiality, satisfying institutional Information Services requirements, and ensuring connectivity required an additional 8 months before the functional system was complete. It is now possible to achieve wireless entry and retrieval of data using a PDA. Potential advantages include collection and entry of data at the same time, easy entry of data from multiple sites, and retrieval of data at the patient's bedside.
PDA: Paradigm-Disrupting Appliance?
ERIC Educational Resources Information Center
Cain, Mark
2003-01-01
Discusses personal digital assistants (PDAs). Highlights include history and characteristics of PDAs; beyond the "organizer" function and use of PDAs in higher education and academic libraries; problems and possibilities of a wirelessly networked PDA in a library; and the future outlook for PDAs. (AEF)
Biomedical digital assistant for ubiquitous healthcare.
Lee, Tae-Soo; Hong, Joo-Hyun; Cho, Myeong-Chan
2007-01-01
The concept of ubiquitous healthcare service, which emerged as one of measures to solve healthcare problems in aged society, means that patients can receive services such as prevention, diagnosis, therapy and prognosis management at any time and in any place with the help of advanced information and communication technology. This service requires not only biomedical digital assistant that can monitor continuously the patients' health condition regardless of time and place, but also wired and wireless communication devices and telemedicine servers that provide doctors with data on patients' present health condition. In order to implement a biomedical digital assistant that is portable and wearable to patients, the present study developed a device that minimizes size, weight and power consumption, measures ECG and PPG signals, and even monitors moving patients' state. The biomedical sensor with the function of wireless communication was designed to be highly portable and wearable, to be operable 24 hours with small-size batteries, and to monitor the subject's heart rate, step count and respiratory rate in his daily life. The biomedical signal receiving device was implemented in two forms, PDA and cellular phone. The movement monitoring device embedded in the battery pack of a cellular phone does not have any problem in operating 24 hours, but the real-time biomedical signal receiving device implemented with PDA operated up to 6 hours due to the limited battery capacity of PDA. This problem is expected to be solved by reducing wireless communication load through improving the processing and storage functions of the sensor. The developed device can transmit a message on the patient's emergency to the remote server through the cellular phone network, and is expected to play crucial roles in the health management of chronic-aged patients in their daily life.
Remote Arrhythmia Monitoring System Developed
NASA Technical Reports Server (NTRS)
York, David W.; Mackin, Michael A.; Liszka, Kathy J.; Lichter, Michael J.
2004-01-01
Telemedicine is taking a step forward with the efforts of team members from the NASA Glenn Research Center, the MetroHealth campus of Case Western University, and the University of Akron. The Arrhythmia Monitoring System is a completed, working test bed developed at Glenn that collects real-time electrocardiogram (ECG) signals from a mobile or homebound patient, combines these signals with global positioning system (GPS) location data, and transmits them to a remote station for display and monitoring. Approximately 300,000 Americans die every year from sudden heart attacks, which are arrhythmia cases. However, not all patients identified at risk for arrhythmias can be monitored continuously because of technological and economical limitations. Such patients, who are at moderate risk of arrhythmias, would benefit from technology that would permit long-term continuous monitoring of electrical cardiac rhythms outside the hospital environment. Embedded Web Technology developed at Glenn to remotely command and collect data from embedded systems using Web technology is the catalyst for this new telemetry system (ref. 1). In the end-to-end system architecture, ECG signals are collected from a patient using an event recorder and are transmitted to a handheld personal digital assistant (PDA) using Bluetooth, a short-range wireless technology. The PDA concurrently tracks the patient's location via a connection to a GPS receiver. A long distance link is established via a standard Internet connection over a 2.5-generation Global System for Mobile Communications/General Packet Radio Service (GSM/GPRS)1 cellular, wireless infrastructure. Then, the digital signal is transmitted to a call center for monitoring by medical professionals.
Reynolds, P A; Harper, J; Dunne, S; Cox, M; Myint, Y K
2007-04-28
To describe a simple technical evaluation of the access, security issues and uses of wireless networked PDAs in a dental clinic and report a pilot study investigating students' educational use of PDAs to access a Virtual Learning Environment (VLE) in a dental clinic. To undertake a technical evaluation of wireless networking to PDAs focusing on security issues, robustness of the system and accessibility particularly to educational resources. To evaluate the impact of using a PDA on undergraduate students in the dental clinic and at home. Part II describes the technical and educational evaluation of PDAs used by one group of 12 undergraduate fourth year students in the Primary Dental Care clinic. A cross over trial of six students with PDAs and six without was carried out during one semester of 12 weeks. Technical issues such as secure internet access using wireless connectivity were addressed. An assessment of the general and educational use and the students' attitudes towards using PDAs was undertaken using online questionnaires and focus group discussions. Over 90% of participants wanted PDAs as part of their dental kit. The potential of PDA use in dental training was demonstrated by a good to excellent response by over 75% of participants to having access to online support materials, particularly videos, being able to make notes for individual study and to keep a diary of their commitments to teaching sessions. Recreational use included a 100% good to excellent response to playing games and keeping a diary. The PDA proved to be a convenient and versatile mode of access to online education. Technical solutions enabled a substantial proportion of the functionality of WebCT (Web Course Tools) to be accessed by the students in a clinical environment. Both novice and experienced users were able to appreciate the use of the PDA and the less able considered that their ICT skills had improved. However, further research is needed to determine how students use a range of new technologies in their undergraduate programmes. The Dental Institute plans to recommend that all students will use this device in the future throughout their five-year curriculum, and the scoping of the implications of this recommendation is underway.
Access Without Authentication: How and Why We Let Anyone Surf Our Wireless
ERIC Educational Resources Information Center
Watkins, Donna
2006-01-01
Wireless hotspots are popping up in local coffee shops everywhere. Anyone with a wireless-ready laptop or PDA can surf the Internet at one of these hotspots. The same is now true for all 32 branches of the Orange County Public Library (OCPL) in California. Though many public library systems are moving toward wireless access, most require patrons…
Kim, Jong-Myoung; Hong, Joo-Hyun; Cho, Myeong-Chan; Cha, Eun-Jong; Lee, Tae-Soo
2007-01-01
The present study purposed to measure the BCG (Ballistocardiogram) of subjects on a wheelchair using a noncontact electro-mechanical film sensor (EMFi sensor) and detect the respiratory rate from BCG in real-time while the subjects are moving. In order to measure wirelessly the BCG of subjects moving on a wheelchair, we made a seat-type noncontact EMFi sensor and developed a transmitter and a receiver using Zigbee wireless RF communication technology. The sensor is embedded with a 3-axis accelerometer to remove the noise of wheelchair vibration from BCG signal. Signal obtained from each sensor goes through the A/D converter and is recorded in the SD (Secure Digital) card in PDA (Personal Digital Assistance) with a receiving part. We also developed a PC (Personal Computer) data analysis program, analyzed data recorded in the SD card using the program, and presented the results in graph. Lastly, this study demonstrated that a warning message can be sent from PDA to the remote server via a CDMA (Code Division Multiple Access) network in case the person on wheelchair falls in emergency. Our experiment was carried out with healthy male and female adults in their 20s who volunteered to help this research. The results of analyzing collected data will show that the respiratory rate can be measured in real-time on a moving wheelchair.
2006-11-01
WPSM system worn by future Warfighters, the medic will have a personal digital assistant (PDA) equipped with the Battlefield Medical Information...has been hit by a bullet or some other projectile. This information is sent wirelessly to a personal digital assistant (PDA) held by the medic...likely to view this vital sign information on a personal digital assistant (PDA) equipped with the Battlefield Medical Information System – Tactical
Park, Jung-Ho; Park, Sung-Ae; Yoon, Soon-Nyoung; Kang, Sung-Rye
2004-04-01
The purpose of this study was to develop a home care nursing network system for operating home care effectively and efficiently by utilizing a wire-wireless network and mobile computing in order to record and send patients' data in real time, and by combining the headquarter office and the local offices with home care nurses over the Internet. It complements the preceding research from 1999 by adding home care nursing standard guidelines and upgrading the PDA program. Method/1 and Prototyping were adopted to develop the main network system. The detailed research process is as follows : 1)home care nursing standard guidelines for Diabetes, cancer and peritoneal-dialysis were added in 12 domains of nursing problem fields with nursing assessment/intervention algorithms. 2) complementing the PDA program was done by omitting and integrating the home care nursing algorithm path which is unnecessary and duplicated. Also, upgrading the PDA system was done by utilizing the machinery and tools where the PDA and the data transmission modem are integrated, CDMX-1X base construction, in order to reduce a transmission error or transmission failure.
NASA Astrophysics Data System (ADS)
Krejcar, Ondrej
New kind of mobile lightweight devices can run full scale applications with same comfort as on desktop devices only with several limitations. One of them is insufficient transfer speed on wireless connectivity. Main area of interest is in a model of a radio-frequency based system enhancement for locating and tracking users of a mobile information system. The experimental framework prototype uses a wireless network infrastructure to let a mobile lightweight device determine its indoor or outdoor position. User location is used for data prebuffering and pushing information from server to user’s PDA. All server data is saved as artifacts along with its position information in building or larger area environment. The accessing of prebuffered data on mobile lightweight device can highly improve response time needed to view large multimedia data. This fact can help with design of new full scale applications for mobile lightweight devices.
2005 Science and Technology for Chem-Bio Information Systems (S and T CBIS) volume 3 Thursday
2005-10-28
radar, lidar, or sodar with computer on-board. Temperature and moisture MW radiometer with computer on- board. Portable meteorological sensors ... Wireless on the go is a way of life now – my cell phone , my PDA, my IPOD (look, I’m “Podcasting”!) and dock it when I’m at home – Same components...Team.. Other specifications will follow… Standardization of the interfaces across all CBRN sensors / devices ! JPEO-CBD 20 Joint Program Executive Office
[Implementation of ECG Monitoring System Based on Internet of Things].
Lu, Liangliang; Chen, Minya
2015-11-01
In order to expand the capabilities of hospital's traditional ECG device and enhance medical staff's work efficiency, an ECG monitoring system based on internet of things is introduced. The system can monitor ECG signals in real time and analyze data using ECG sensor, PDA, Web servers, which embeds C language, Android systems, .NET, wireless network and other technologies. After experiments, it can be showed that the system has high reliability and stability and can bring the convenience to medical staffs.
Enhanced technologies for unattended ground sensor systems
NASA Astrophysics Data System (ADS)
Hartup, David C.
2010-04-01
Progress in several technical areas is being leveraged to advantage in Unattended Ground Sensor (UGS) systems. This paper discusses advanced technologies that are appropriate for use in UGS systems. While some technologies provide evolutionary improvements, other technologies result in revolutionary performance advancements for UGS systems. Some specific technologies discussed include wireless cameras and viewers, commercial PDA-based system programmers and monitors, new materials and techniques for packaging improvements, low power cueing sensor radios, advanced long-haul terrestrial and SATCOM radios, and networked communications. Other technologies covered include advanced target detection algorithms, high pixel count cameras for license plate and facial recognition, small cameras that provide large stand-off distances, video transmissions of target activity instead of still images, sensor fusion algorithms, and control center hardware. The impact of each technology on the overall UGS system architecture is discussed, along with the advantages provided to UGS system users. Areas of analysis include required camera parameters as a function of stand-off distance for license plate and facial recognition applications, power consumption for wireless cameras and viewers, sensor fusion communication requirements, and requirements to practically implement video transmission through UGS systems. Examples of devices that have already been fielded using technology from several of these areas are given.
Documet, Jorge; Liu, Brent J; Documet, Luis; Huang, H K
2006-07-01
This paper describes a picture archiving and communication system (PACS) tool based on Web technology that remotely manages medical images between a PACS archive and remote destinations. Successfully implemented in a clinical environment and also demonstrated for the past 3 years at the conferences of various organizations, including the Radiological Society of North America, this tool provides a very practical and simple way to manage a PACS, including off-site image distribution and disaster recovery. The application is robust and flexible and can be used on a standard PC workstation or a Tablet PC, but more important, it can be used with a personal digital assistant (PDA). With a PDA, the Web application becomes a powerful wireless and mobile image management tool. The application's quick and easy-to-use features allow users to perform Digital Imaging and Communications in Medicine (DICOM) queries and retrievals with a single interface, without having to worry about the underlying configuration of DICOM nodes. In addition, this frees up dedicated PACS workstations to perform their specialized roles within the PACS workflow. This tool has been used at Saint John's Health Center in Santa Monica, California, for 2 years. The average number of queries per month is 2,021, with 816 C-MOVE retrieve requests. Clinical staff members can use PDAs to manage image workflow and PACS examination distribution conveniently for off-site consultations by referring physicians and radiologists and for disaster recovery. This solution also improves radiologists' effectiveness and efficiency in health care delivery both within radiology departments and for off-site clinical coverage.
Development of a personal digital assistant-based wireless application in clinical practice.
Chen, Yen-Cheng; Chiu, Hou-Chang; Tsai, Ming-Dar; Chang, Hang; Chong, Chee-Fah
2007-02-01
Our study aims to develop a personal digital assistant (PDA)-based wireless application in medical information processing by using Bluetooth and IEEE 802.11b wireless standards and SyncML codes. In this study, an "integrated database access module" is used to provide a unified integrated access interface while consistency of wireless data transmission is achieved by using the standardized SyncML protocol. A prototype of the system has been developed, implemented, and tested for its mobility, usability, stability, and performance with questionnaire survey. Response time for browsing/searching was usually less than 3s. The average time intervals needed for data transmissions were 68.6+/-8.5s for Bluetooth and 47.0+/-4.8s for 802.11b. The five-point Likert scale (from 1=least to 5=most) questionnaire survey of 30 medical professionals yielded a high degree of satisfaction with the system's mobility (4.18+/-0.89), usability (4.69+/-0.90), stability (3.81+/-0.94), and performance (3.97+/-0.88). The results of our study suggested that PDA applications which exploit wireless communication are convenient and feasible in clinical practice.
A PDA-based electrocardiogram/blood pressure telemonitor for telemedicine.
Bolanos, Marcos; Nazeran, Homayoun; Gonzalez, Izzac; Parra, Ricardo; Martinez, Christopher
2004-01-01
An electrocardiogram (ECG) / blood pressure (BP) telemonitor consisting of comprehensive integration of various electrical engineering concepts, devices, and methods was developed. This personal digital assistant-based (PDAbased) system focused on integration of biopotential amplifiers, photoplethysmographic measurement of blood pressure, microcontroller devices, programming methods, wireless transmission, signal filtering and analysis, interfacing, and long term memory devices (24 hours) to develop a state-of-the-art ECG/BP telemonitor. These instrumentation modules were developed and tested to realize a complete and compact system that could be deployed to assist in telemedicine applications and heart rate variability studies. The specific objective of this device was to facilitate the long term monitoring and recording of ECG and blood pressure signals. This device was able to acquire ECG/BP waveforms, transmit them wirelessly to a PDA, save them onto a compact flash memory, and display them on the LCD screen of the PDA. It was also capable of calculating the heart rate (HR) in beats per minute, and providing systolic and diastolic blood pressure values.
An implementation of wireless medical image transmission system on mobile devices.
Lee, SangBock; Lee, Taesoo; Jin, Gyehwan; Hong, Juhyun
2008-12-01
The advanced technology of computing system was followed by the rapid improvement of medical instrumentation and patient record management system. The typical examples are hospital information system (HIS) and picture archiving and communication system (PACS), which computerized the management procedure of medical records and images in hospital. Because these systems were built and used in hospitals, doctors out of hospital have problems to access them immediately on emergent cases. To solve these problems, this paper addressed the realization of system that could transmit the images acquired by medical imaging systems in hospital to the remote doctors' handheld PDA's using CDMA cellular phone network. The system consists of server and PDA. The server was developed to manage the accounts of doctors and patients and allocate the patient images to each doctor. The PDA was developed to display patient images through remote server connection. To authenticate the personal user, remote data access (RDA) method was used in PDA accessing the server database and file transfer protocol (FTP) was used to download patient images from the remove server. In laboratory experiments, it was calculated to take ninety seconds to transmit thirty images with 832 x 488 resolution and 24 bit depth and 0.37 Mb size. This result showed that the developed system has no problems for remote doctors to receive and review the patient images immediately on emergent cases.
Hand-held computers in healthcare: what software programs are available?
Gillingham, Wayne; Holt, Alec; Gillies, John
2002-09-27
The technology sector of healthcare is entering a new evolutionary phase. The medical community has an obligation to the public to provide the safest, most effective healthcare possible. This is more achievable with the use of computer technology at the point of care, and small, portable devices could fulfil this role. A PriceWaterhouse Coopers 2001 survey on information technology in physician practices found that 60% of respondents say that physicians in their organisation use personal digital assistants (PDAs), compared with 26% in the 2000 technology survey. This trend is expected to continue to the point where these devices will have their position on a physician s desk next to the stethoscope. Once this electronic evolution occurs, doctors will be able to practice medicine with greater ease and safety. In our opinion, the new generation of PDA mobile devices will be the tools to enable a transformation of healthcare to a paperless, wireless world. This article focuses on uses of PDAs in healthcare, whether by the registrar, consultant, nurse, student, teacher, patient, medical or surgical director. Current PDA healthcare software is categorised and discussed in the following five groups: 1) reference/text book; 2) calculator; 3) patient management/logbook; 4) personal clinical/study notebook; 5) utility software.
NASA Astrophysics Data System (ADS)
Yang, Keon Ho; Jung, Haijo; Kang, Won-Suk; Jang, Bong Mun; Kim, Joong Il; Han, Dong Hoon; Yoo, Sun-Kook; Yoo, Hyung-Sik; Kim, Hee-Joung
2006-03-01
The wireless mobile service with a high bit rate using CDMA-1X EVDO is now widely used in Korea. Mobile devices are also increasingly being used as the conventional communication mechanism. We have developed a web-based mobile system that communicates patient information and images, using CDMA-1X EVDO for emergency diagnosis. It is composed of a Mobile web application system using the Microsoft Windows 2003 server and an internet information service. Also, a mobile web PACS used for a database managing patient information and images was developed by using Microsoft access 2003. A wireless mobile emergency patient information and imaging communication system is developed by using Microsoft Visual Studio.NET, and JPEG 2000 ActiveX control for PDA phone was developed by using the Microsoft Embedded Visual C++. Also, the CDMA-1X EVDO is used for connections between mobile web servers and the PDA phone. This system allows fast access to the patient information database, storing both medical images and patient information anytime and anywhere. Especially, images were compressed into a JPEG2000 format and transmitted from a mobile web PACS inside the hospital to the radiologist using a PDA phone located outside the hospital. Also, this system shows radiological images as well as physiological signal data, including blood pressure, vital signs and so on, in the web browser of the PDA phone so radiologists can diagnose more effectively. Also, we acquired good results using an RW-6100 PDA phone used in the university hospital system of the Sinchon Severance Hospital in Korea.
Wireless-PDA-controlled image workflow from PACS: the next trend in the health care enterprise?
NASA Astrophysics Data System (ADS)
Erberich, Stephan G.; Documet, Jorge; Zhou, Michael Z.; Cao, Fei; Liu, Brent J.; Mogel, Greg T.; Huang, H. K.
2003-05-01
Image workflow in today's Picture Archiving and Communication Systems (PACS) is controlled from fixed Display Workstations (DW) using proprietary control interfaces. A remote access to the Hospital Information System (HIS) and Radiology Information System (RIS) for urgent patient information retrieval does not exist or gradually become available. The lack for remote access and workflow control for HIS and RIS is especially true when it comes to medical images of a PACS on Department or Hospital level. As images become more complex and data sizes expand rapidly with new image techniques like functional MRI, Mammography or routine spiral CT to name a few, the access and manageability becomes an important issue. Long image downloads or incomplete work lists cannot be tolerated in a busy health care environment. In addition, the domain of the PACS is no longer limited to the imaging department and PACS is also being used in the ER and emergency care units. Thus a prompt and secure access and manageability not only by the radiologist, but also from the physician becomes crucial to optimally utilize the PACS in the health care enterprise of the new millennium. The purpose of this paper is to introduce a concept and its implementation of a remote access and workflow control of the PACS combining wireless, Internet and Internet2 technologies. A wireless device, the Personal Digital Assistant (PDA), is used to communicate to a PACS web server that acts as a gateway controlling the commands for which the user has access to the PACS server. The commands implemented for this test-bed are query/retrieve of the patient list and study list including modality, examination, series and image selection and pushing any list items to a selected DW on the PACS network.
Jacobs, K; Foley, G; Punnett, L; Hall, V; Gore, R; Brownson, E; Ansong, E; Markowitz, J; McKinnon, M; Steinberg, S; Ing, A; Wuest, Ellen; Dibiccari, Leah
2011-02-01
The objective of this pilot study was to identify if notebook accessories (ergonomic chair, desktop monitor and notebook riser) combined with a wireless keyboard, mouse and participatory ergonomics training would have the greatest impact on reducing self-reported upper extremity musculoskeletal discomfort in university students. In addition to pre-post computing and health surveys, the Ecological Momentary Assessment was used to capture change in discomfort over time using a personal digital assistant (PDA) as the e-diary. The PDA was programmed with a survey containing 45 questions. Four groups of university students were randomised to either intervention (three external computer accessories) or to control. Participants reported less discomfort with the ergonomic chair and notebook riser based on the pre-post survey data and the e-diary/PDA ANOVA analysis. However, the PDA data, adjusted for the effect of hours per day of computer use, showed no benefit of the chair and limited benefit from the riser. Statement of Relevance:University students' use of notebook computers has increased. This study found evidence of a positive effect of an adjustable chair or notebook riser when combined with ergonomic training on reducing discomfort. Daily notebook computer use of 4 h was confirmed as a risk factor. Without some form of ergonomic intervention, these students are likely to enter the workforce with poor computing habits, which places them on the road to future injuries as technology continues to play a dominant role in their lives.
Diffusion of innovations: smartphones and wireless anatomy learning resources.
Trelease, Robert B
2008-01-01
The author has previously reported on principles of diffusion of innovations, the processes by which new technologies become popularly adopted, specifically in relation to anatomy and education. In presentations on adopting handheld computers [personal digital assistants (PDAs)] and personal media players for health sciences education, particular attention has been directed to the anticipated integration of PDA functions into popular cellular telephones. However, limited distribution of early "smartphones" (e.g., Palm Treo and Blackberry) has provided few potential users for anatomical learning resources. In contrast, iPod media players have been self-adopted by millions of students, and "podcasting" has become a popular medium for distributing educational media content. The recently introduced Apple iPhone has combined smartphone and higher resolution media player capabilities. The author successfully tested the iPhone and the "work alike" iPod touch wireless media player with text-based "flashcard" resources, existing PDF educational documents, 3D clinical imaging data, lecture "podcasts," and clinical procedure video. These touch-interfaced, mobile computing devices represent just the first of a new generation providing practical, scalable wireless Web access with enhanced multimedia capabilities. With widespread student self-adoption of such new personal technology, educators can look forward to increasing portability of well-designed, multiplatform "learn anywhere" resources. Copyright 2008 American Association of Anatomists
Kim, Dong Keun; Yoo, Sun K; Park, Jeong Jin; Kim, Sun Ho
2007-06-01
Remote teleconsultation by specialists is important for timely, correct, and specialized emergency surgical and medical decision making. In this paper, we designed a new personal digital assistant (PDA)-phone-based emergency teleradiology system by combining cellular communication with Bluetooth-interfaced local wireless links. The mobility and portability resulting from the use of PDAs and wireless communication can provide a more effective means of emergency teleconsultation without requiring the user to be limited to a fixed location. Moreover, it enables synchronized radiological image sharing between the attending physician in the emergency room and the remote specialist on picture archiving and communication system terminals without distorted image acquisition. To enable rapid and fine-quality radiological image transmission over a cellular network in a secure manner, progressive compression and security mechanisms have been incorporated. The proposed system is tested over a code division Multiple Access 1x-Evolution Data-Only network to evaluate the performance and to demonstrate the feasibility of this system in a real-world setting.
Pärkkä, Juha; Cluitmans, Luc; Ermes, Miikka
2010-09-01
Inactive and sedentary lifestyle is a major problem in many industrialized countries today. Automatic recognition of type of physical activity can be used to show the user the distribution of his daily activities and to motivate him into more active lifestyle. In this study, an automatic activity-recognition system consisting of wireless motion bands and a PDA is evaluated. The system classifies raw sensor data into activity types online. It uses a decision tree classifier, which has low computational cost and low battery consumption. The classifier parameters can be personalized online by performing a short bout of an activity and by telling the system which activity is being performed. Data were collected with seven volunteers during five everyday activities: lying, sitting/standing, walking, running, and cycling. The online system can detect these activities with overall 86.6% accuracy and with 94.0% accuracy after classifier personalization.
1ST International Workshop on Managing Interactions in Smart Environments (MANSE 99)
1999-12-01
having diverse functionality. It seems likely that eventually the functionality of PDA’s and mobile phones will be integrated into similar sized devices ...The O’Reilly institute is soon to be wired with sensors and detection devices which will allow wireless communication and interaction with the...on wireless short-range communication. The prototypes are functionally self- contained mobile devices that do not rely on any further infrastructure
Chinese Nurses' Acceptance of PDA: A Cross-Sectional Survey Using a Technology Acceptance Model.
Wang, Yanling; Xiao, Qian; Sun, Liu; Wu, Ying
2016-01-01
This study explores Chinese nurses' acceptance of PDA, using a questionnaire based on the framework of Technology Acceptance Model (TAM). 357 nurses were involved in the study. The results reveal the scores of the nurses' acceptance of PDA were means 3.18~3.36 in four dimensions. The younger of nurses, the higher nurses' title, the longer previous usage time, the more experienced using PDA, and the more acceptance of PDA. Therefore, the hospital administrators may change strategies to enhance nurses' acceptance of PDA, and promote the wide application of PDA.
NASA Astrophysics Data System (ADS)
Liu, Brent J.; Documet, Luis; Documet, Jorge; Huang, H. K.; Muldoon, Jean
2004-04-01
An Application Service Provider (ASP) archive model for disaster recovery for Saint John"s Health Center (SJHC) clinical PACS data has been implemented using a Fault-Tolerant Archive Server at the Image Processing and Informatics Laboratory, Marina del Rey, CA (IPIL) since mid-2002. The purpose of this paper is to provide clinical experiences with the implementation of an ASP model backup archive in conjunction with handheld wireless technologies for a particular disaster recovery scenario, an earthquake, in which the local PACS archive and the hospital are destroyed and the patients are moved from one hospital to another. The three sites involved are: (1) SJHC, the simulated disaster site; (2) IPIL, the ASP backup archive site; and (3) University of California, Los Angeles Medical Center (UCLA), the relocated patient site. An ASP backup archive has been established at IPIL to receive clinical PACS images daily using a T1 line from SJHC for backup and disaster recovery storage. Procedures were established to test the network connectivity and data integrity on a regular basis. In a given disaster scenario where the local PACS archive has been destroyed and the patients need to be moved to a second hospital, a wireless handheld device such as a Personal Digital Assistant (PDA) can be utilized to route images to the second hospital site with a PACS and reviewed by radiologists. To simulate this disaster scenario, a wireless network was implemented within the clinical environment in all three sites: SJHC, IPIL, and UCLA. Upon executing the disaster scenario, the SJHC PACS archive server simulates a downtime disaster event. Using the PDA, the radiologist at UCLA can query the ASP backup archive server at IPIL for PACS images and route them directly to UCLA. Implementation experiences integrating this solution within the three clinical environments as well as the wireless performance are discussed. A clinical downtime disaster scenario was implemented and successfully tested. Radiologists were able to successfully query PACS images utilizing a wireless handheld device from the ASP backup archive at IPIL and route the PACS images directly to a second clinical site at UCLA where they and the patients are located at that time. In a disaster scenario, using a wireless device, radiologists at the disaster health care center can route PACS data from an ASP backup archive server to be reviewed in a live clinical PACS environment at a secondary site. This solution allows Radiologists to use a wireless handheld device to control the image workflow and to review PACS images during a major disaster event where patients must be moved to a secondary site.
Radiology on handheld devices: image display, manipulation, and PACS integration issues.
Raman, Bhargav; Raman, Raghav; Raman, Lalithakala; Beaulieu, Christopher F
2004-01-01
Handheld personal digital assistants (PDAs) have undergone continuous and substantial improvements in hardware and graphics capabilities, making them a compelling platform for novel developments in teleradiology. The latest PDAs have processor speeds of up to 400 MHz and storage capacities of up to 80 Gbytes with memory expansion methods. A Digital Imaging and Communications in Medicine (DICOM)-compliant, vendor-independent handheld image access system was developed in which a PDA server acts as the gateway between a picture archiving and communication system (PACS) and PDAs. The system is compatible with most currently available PDA models. It is capable of both wired and wireless transfer of images and includes custom PDA software and World Wide Web interfaces that implement a variety of basic image manipulation functions. Implementation of this system, which is currently undergoing debugging and beta testing, required optimization of the user interface to efficiently display images on smaller PDA screens. The PDA server manages user work lists and implements compression and security features to accelerate transfer speeds, protect patient information, and regulate access. Although some limitations remain, PDA-based teleradiology has the potential to increase the efficiency of the radiologic work flow, increasing productivity and improving communication with referring physicians and patients. Copyright RSNA, 2004
Wu, Vincent Wing-Cheung; Tang, Fuk-hay; Cheung, Wai-kwan; Chan, Kit-chi
2013-02-01
In localisation of radiotherapy treatment field, the oncologist is present at the simulator to approve treatment details produced by the therapist. Problems may arise if the oncologist is not available and the patient requires urgent treatment. The development of a tele-localisation system is a potential solution, where the oncologist uses a personal digital assistant (PDA) to localise the treatment field on the image sent from the simulator through wireless communication and returns the information to the therapist after his or her approval. Our team developed the first tele-localisation prototype, which consisted of a server workstation (simulator) for the administration of digital imaging and communication in medicine localisation images including viewing and communication with the PDA via a Wi-Fi network; a PDA (oncologist's site) installed with the custom-built programme that synchronises with the server workstation and performs treatment field editing. Trial tests on accuracy and speed of the prototype system were conducted on 30 subjects with the treatment regions covering the neck, skull, chest and pelvis. The average time required in performing the localisation using the PDA was less than 1.5 min, with the blocked field longer than the open field. The transmission speed of the four treatment regions was similar. The average physical distortion of the images was within 4.4% and the accuracy of field size indication was within 5.3%. Compared with the manual method, the tele-localisation system presented with an average deviation of 5.5%. The prototype system fulfilled the planned objectives of tele-localisation procedure with reasonable speed and accuracy. © 2012 The Authors. Journal of Medical Imaging and Radiation Oncology © 2012 The Royal Australian and New Zealand College of Radiologists.
Learning Objects for Educational Applications via PDA Technology
ERIC Educational Resources Information Center
Churchill, Daniel
2008-01-01
This article discusses an ongoing study into issues relevant to the design of learning objects for educational applications via portable digital assistant (PDA) technology. The specific areas of inquiry in this study are: the kinds of learning objects that are effective for PDA delivery; contexts for their effective educational applications; and…
Basak, Ecem; Gumussoy, Cigdem Altin; Calisir, Fethi
2015-01-01
This study aims at identifying the factors affecting the intention to use personal digital assistant (PDA) technology among physicians in Turkey using an extended Technology Acceptance Model (TAM). A structural equation-modeling approach was used to identify the variables that significantly affect the intention to use PDA technology. The data were collected from 339 physicians in Turkey. Results indicated that 71% of the physicians' intention to use PDA technology is explained by perceived usefulness and perceived ease of use. On comparing both, the perceived ease of use has the strongest effect, whereas the effect of perceived enjoyment on behavioral intention to use is found to be insignificant. This study concludes with the recommendations for managers and possible future research.
A PDA-based flexible telecommunication system for telemedicine applications.
Nazeran, Homer; Setty, Sunil; Haltiwanger, Emily; Gonzalez, Virgilio
2004-01-01
Technology has been used to deliver health care at a distance for many years. Telemedicine is a rapidly growing area and recently there are studies devoted to prehospital care of patients in emergency cases. In this work we have developed a compact, reliable, and low cost PDA-based telecommunication device for telemedicine applications to transmit audio, still images, and vital signs from a remote site to a fixed station such as a clinic or a hospital in real time. This was achieved based on a client-server architecture. A Pocket PC, a miniature camera, and a hands-free microphone were used at the client site and a desktop computer running the Windows XP operating system was used as a server. The server was located at a fixed station. The system was implemented on TCP/IP and HTTP protocol. Field tests have shown that the system can reliably transmit still images, audio, and sample vital signs from a simulated remote site to a fixed station either via a wired or wireless network in real time. The Pocket PC was used at the client site because of its compact size, low cost and processing capabilities.
Infusing PDA technology into nursing education.
White, Ann; Allen, Patricia; Goodwin, Linda; Breckinridge, Daya; Dowell, Jeffery; Garvy, Ryan
2005-01-01
Use of the personal digital assistant (PDA) has been infused into the accelerated baccalaureate program at Duke University to help prepare nursing students for professional practice. The authors provide an overview of the use of PDAs in the classroom, laboratory, and clinical setting. Technical aspects of PDA infusion and steps to ensure regulatory compliance are explored. Benefits of PDA use by both faculty and students in the program and challenges met with the infusion of this technology are also described.
Back to the future: personal digital assistants in nursing education.
McLeod, Renee P; Mays, Mary Z
2008-12-01
This article provides an overview of the current state of the art for incorporating personal digital assistants (PDAs) into nursing education. The development of PDA technology and the lessons learned by educators integrating PDA technology into nursing curricula are described. The current cycle of PDA evolution is discussed and contrasted with a proposed model for maximizing the impact of PDAs on technological innovation in nursing education and practice.
Seamless interworking architecture for WBAN in heterogeneous wireless networks with QoS guarantees.
Khan, Pervez; Ullah, Niamat; Ullah, Sana; Kwak, Kyung Sup
2011-10-01
The IEEE 802.15.6 standard is a communication standard optimized for low-power and short-range in-body/on-body nodes to serve a variety of medical, consumer electronics and entertainment applications. Providing high mobility with guaranteed Quality of Service (QoS) to a WBAN user in heterogeneous wireless networks is a challenging task. A WBAN uses a Personal Digital Assistant (PDA) to gather data from body sensors and forwards it to a remote server through wide range wireless networks. In this paper, we present a coexistence study of WBAN with Wireless Local Area Networks (WLAN) and Wireless Wide Area Networks (WWANs). The main issue is interworking of WBAN in heterogenous wireless networks including seamless handover, QoS, emergency services, cooperation and security. We propose a Seamless Interworking Architecture (SIA) for WBAN in heterogenous wireless networks based on a cost function. The cost function is based on power consumption and data throughput costs. Our simulation results show that the proposed scheme outperforms typical approaches in terms of throughput, delay and packet loss rate.
NASA Astrophysics Data System (ADS)
Hussmann, Stephan; Lau, Wing Y.; Chu, Terry; Grothof, Markus
2003-07-01
Traditionally, the measuring or monitoring system of manufacturing industries uses sensors, computers and screens for their quality control (Q.C.). The acquired information is fed back to the control room by wires, which - for obvious reason - are not suitable in many environments. This paper describes a method to solve this problem by employing the new Bluetooth technology to set up a complete new system, where a total wireless solution is made feasible. This new Q.C. system allows several line scan cameras to be connected at once to a graphical user interface (GUI) that can monitor the production process. There are many Bluetooth devices available on the market such as cell-phones, headsets, printers, PDA etc. However, the detailed application is a novel implementation in the industrial Q.C. area. This paper will contain more details about the Bluetooth standard and why it is used (nework topologies, host controller interface, data rates, etc.), the Bluetooth implemetation in the microcontroller of the line scan camera, and the GUI and its features.
Enterprise digital assistants: the progression of wireless clinical computing.
Bergeron, Bryan P
2002-01-01
By virtue of increasingly pervasive wireless connectivity, the proliferation of wireless handheld devices in clinical care is rapidly transforming the concept of the personal digital assistant (PDA) to the enterprise digital assistant (EDA). Wireless handheld devices are becoming extensions of the central hospital information system, in which it's understood that the health care enterprise, not the clinician carrying the information-dispensing device, owns the data. The practical implication for clinicians is that, despite the potential long-term benefits of seamless, just-in-time clinical data access, this paradigm shift portends decreased efficiency in the short term, as clinicians duplicate clinical data collection on private devices. Assuming eventual clinician acceptance, EDAs can form the basis of a national real-time clinical data acquisition system that ensures uniform prescribing, decision support, and diagnosis, and the means for tracking unusual disease presentation patterns that could be indicative of bioterrorism or natural disease outbreaks.
Kuiper, RuthAnne
2010-01-01
The utility of personal digital assistants (PDA) as a point of care resource in health care practice and education presents new challenges for nursing faculty. While there is a plethora of PDA resources available, little is known about the variables that effect student learning and technology adoption. In this study nursing students used PDA software programs which included a drug guide, medical dictionary, laboratory manual and nursing diagnosis manual during acute care clinical experiences. Analysis of student journals comparative reflective statements about the PDA as an adjunct to other available resources in clinical practice are presented. The benefits of having a PDA included readily available data, validation of thinking processes, and facilitation of care plan re-evaluation. Students reported increased frequency of use and independence. Significant correlations between user perceptions and computer self-efficacy suggested greater confidence in abilities with technology resulting in increased self-awareness and achievement of learning outcomes.
Medication error reduction and the use of PDA technology.
Greenfield, Sue
2007-03-01
The purpose of this study was to determine whether nursing medication errors could be reduced and nursing care provided more efficiently using personal digital assistant (PDA) technology. The sample for this study consisted of junior and senior undergraduate baccalaureate nursing students. By self-selection of owning a PDA or not, students were placed in the PDA (experimental) group or the textbook (control) group, provided with a case study to read, and asked to answer six questions (i.e., three medication administration calculations and three clinical decisions based on medication administration). The analysis of collected data, calculated using a t test, revealed that the PDA group answered the six questions with greater accuracy and speed than did the textbook group.
Using mHealth Technology to Enhance Self-Monitoring for Weight Loss A Randomized Trial
Burke, Lora E.; Styn, Mindi A.; Sereika, Susan M.; Conroy, Molly B.; Ye, Lei; Glanz, Karen; Sevick, Mary Ann; Ewing, Linda J.
2012-01-01
Background Self-monitoring for weight loss has traditionally been performed with paper diaries. Technologic advances could reduce the burden of self-monitoring and provide feedback to enhance adherence. Purpose To determine if self-monitoring diet using a PDA only or the PDA with daily tailored feedback (PDA+FB), was superior to using a paper diary on weight loss and maintenance. Design The Self-Monitoring and Recording Using Technology (SMART) Trial was a 24-month RCCT; participants were randomly assigned to one of three self-monitoring groups. Setting/participants From 2006 to 2008, 210 overweight/obese adults (84.8% female, 78.1% white) were recruited from the community. Data were analyzed in 2011. Intervention Participants received standard behavioral treatment for weight loss which included dietary and physical activity goals, encouraged the use of self-monitoring, and was delivered in group sessions. Main outcome measures Percentage weight change at 24 months, adherence to self-monitoring over time. Results Study retention was 85.6%. The mean percentage weight loss at 24 months was not different among groups (paper diary: −1.94% [95% CI= −3.88, 0.01], PDA: −1.38% [95% CI= – 3.38, 0.62], PDA+FB: –2.32% [95% CI= –4.29, −0.35]); only the PDA+FB group (p=0.02) demonstrated a significant loss. For adherence to self-monitoring, there was a time-by-treatment group interaction between the combined PDA groups and the paper diary group (p=0.03) but no difference between PDA and PDA+FB groups (p=0.49). Across all groups, weight loss was greater for those who were adherent ≥60% versus <30% of the time, p<0.001. Conclusions PDA+FB use resulted in a small weight loss at 24 months; PDA use resulted in greater adherence to dietary self-monitoring over time. However, for sustained weight loss, adherence to self-monitoring is more important than the method used to self-monitor. A daily feedback message delivered remotely enhanced adherence and improved weight loss, which suggests that technology can play a role in improving weight loss. PMID:22704741
Mobile collaborative medical display system.
Park, Sanghun; Kim, Wontae; Ihm, Insung
2008-03-01
Because of recent advances in wireless communication technologies, the world of mobile computing is flourishing with a variety of applications. In this study, we present an integrated architecture for a personal digital assistant (PDA)-based mobile medical display system that supports collaborative work between remote users. We aim to develop a system that enables users in different regions to share a working environment for collaborative visualization with the potential for exploring huge medical datasets. Our system consists of three major components: mobile client, gateway, and parallel rendering server. The mobile client serves as a front end and enables users to choose the visualization and control parameters interactively and cooperatively. The gateway handles requests and responses between mobile clients and the rendering server for efficient communication. Through the gateway, it is possible to share working environments between users, allowing them to work together in computer supported cooperative work (CSCW) mode. Finally, the parallel rendering server is responsible for performing heavy visualization tasks. Our experience indicates that some features currently available to our mobile clients for collaborative scientific visualization are limited due to the poor performance of mobile devices and the low bandwidth of wireless connections. However, as mobile devices and wireless network systems are experiencing considerable elevation in their capabilities, we believe that our methodology will be utilized effectively in building quite responsive, useful mobile collaborative medical systems in the very near future.
Who’s Using PDAs? Estimates of PDA Use by Health Care Providers: A Systematic Review of Surveys
El Emam, Khaled
2006-01-01
Background Personal digital assistants (PDAs) find many uses in health care. Knowing rates of collective PDA use among health care providers is an important guiding step to further understanding those health care contexts that are most suited to PDA use and whether PDAs provide improved health outcomes. Objectives The objectives of this study were to estimate current and future PDA use among health care providers and to discuss possible implications of that use on choice of technology in clinical practice and research. Methods This study was a systematic review of PDA usage surveys. Surveys were identified as part of an ongoing systematic review on the use of handheld devices. Reports from eight databases covering both biomedical sciences and engineering (1993-2006) were screened against distinct eligibility criteria. Data from included surveys were extracted and verified in a standardized way and were assessed descriptively. Results We identified 23 relevant surveys, 15 of which were derived from peer-reviewed journals. This cohort of surveys was published between 2000 and 2005. Overall, since 1999, there is clear evidence of an increasing trend in PDA use. The current overall adoption rate for individual professional use ranges between 45% and 85%, indicating high but somewhat variable adoption, primarily among physicians. Conclusions Younger physicians and residents and those working in large and hospital-based practices are more likely to use a PDA. The adoption rate is now at its highest rate of increase according to a commonly accepted diffusion of innovations model. A common problem with the evaluation of information technology is that use frequently precedes research. This is the case here, in which PDA adoption rates are already high and projections are for rapid growth in the short term. In general, it appears that professional PDA use in health care settings involves more administrative and organizational tasks than those related to patient care, perhaps signaling where the growth in adoption is most likely to occur. We conclude that physicians are likely accustomed to using a PDA, and, therefore, technology expertise will probably not be a barrier to implementing PDA applications. However, there is an urgent need to evaluate the effectiveness and efficiency of specific tasks using handheld technology to inform those developing and those using PDA applications. PMID:16867970
Remote personal health monitoring with radio waves
NASA Astrophysics Data System (ADS)
Nguyen, Andrew
2008-03-01
We present several techniques utilizing radio-frequency identification (RFID) technology for personal health monitoring. One technique involves using RFID sensors external to the human body, while another technique uses both internal and external RFID sensors. Simultaneous monitoring of many patients in a hospital setting can also be done using networks of RFID sensors. All the monitoring are done wirelessly, either continuously or periodically in any interval, in which the sensors collect information on human parts such as the lungs or heart and transmit this information to a router, PC or PDA device connected to the internet, from which patient's condition can be diagnosed and viewed by authorized medical professionals in remote locations. Instantaneous information allows medical professionals to intervene properly and timely to prevent possible catastrophic effects to patients. The continuously monitored information provides medical professionals more complete and long-term studies of patients. All of these result in not only enhancement of the health treatment quality but also significant reduction of medical expenditure. These techniques demonstrate that health monitoring of patients can be done wirelessly at any time and any place without interfering with the patients' normal activities. Implementing the RFID technology would not only help reduce the enormous and significantly growing medical costs in the U.S.A., but also help improve the health treatment capability as well as enhance the understanding of long-term personal health and illness.
Wireless Zigbee strain gage sensor system for structural health monitoring
NASA Astrophysics Data System (ADS)
Ide, Hiroshi; Abdi, Frank; Miraj, Rashid; Dang, Chau; Takahashi, Tatsuya; Sauer, Bruce
2009-05-01
A compact cell phone size radio frequency (ZigBee) wireless strain measurement sensor system to measure the structural strain deformation was developed. The developed system provides an accurate strain measurement data stream to the Internet for further Diagnostic and Prognostic (DPS) correlation. Existing methods of structural measurement by strain sensors (gauges) do not completely satisfy problems posed by continuous structural health monitoring. The need for efficient health monitoring methods with real-time requirements to bidirectional data flow from sensors and to a commanding device is becoming critical for keeping our daily life safety. The use of full-field strain measurement techniques could reduce costly experimental programs through better understanding of material behavior. Wireless sensor-network technology is a monitoring method that is estimated to grow rapidly providing potential for cost savings over traditional wired sensors. The many of currently available wireless monitoring methods have: the proactive and constant data rate character of the data streams rather than traditional reactive, event-driven data delivery; mostly static node placement on structures with limited number of nodes. Alpha STAR Electronics' wireless sensor network system, ASWN, addresses some of these deficiencies, making the system easier to operate. The ASWN strain measurement system utilizes off-the-shelf sensors, namely strain gauges, with an analog-to-digital converter/amplifier and ZigBee radio chips to keep cost lower. Strain data is captured by the sensor, converted to digital form and delivered to the ZigBee radio chip, which in turn broadcasts the information using wireless protocols to a Personal Data Assistant (PDA) or Laptop/Desktop computers. From here, data is forwarded to remote computers for higher-level analysis and feedback using traditional cellular and satellite communication or the Ethernet infrastructure. This system offers a compact size, lower cost, and temperature insensitivity for critical structural applications, which require immediate monitoring and feedback.
Kim, Dong-Keun; Yoo, Sun K; Kim, Sun H
2005-01-01
The instant transmission of radiological images may be important for making rapid clinical decisions about emergency patients. We have examined an instant image transfer system based on a personal digital assistant (PDA) phone with a built-in camera. Images displayed on a picture archiving and communication systems (PACS) monitor can be captured by the camera in the PDA phone directly. Images can then be transmitted from an emergency centre to a remote physician via a wireless high-bandwidth network (CDMA 1 x EVDO). We reviewed the radiological lesions in 10 normal and 10 abnormal cases produced by modalities such as computerized tomography (CT), magnetic resonance (MR) and digital angiography. The images were of 24-bit depth and 1,144 x 880, 1,120 x 840, 1,024 x 768, 800 x 600, 640 x 480 and 320 x 240 pixels. Three neurosurgeons found that for satisfactory remote consultation a minimum size of 640 x 480 pixels was required for CT and MR images and 1,024 x 768 pixels for angiography images. Although higher resolution produced higher clinical satisfaction, it also required more transmission time. At the limited bandwidth employed, higher resolutions could not be justified.
Ellingson, Roger M; Oken, Barry
2010-01-01
Report contains the design overview and key performance measurements demonstrating the feasibility of generating and recording ambulatory visual stimulus evoked potentials using the previously reported custom Complementary and Alternative Medicine physiologic data collection and monitoring system, CAMAS. The methods used to generate visual stimuli on a PDA device and the design of an optical coupling device to convert the display to an electrical waveform which is recorded by the CAMAS base unit are presented. The optical sensor signal, synchronized to the visual stimulus emulates the brain's synchronized EEG signal input to CAMAS normally reviewed for the evoked potential response. Most importantly, the PDA also sends a marker message over the wireless Bluetooth connection to the CAMAS base unit synchronized to the visual stimulus which is the critical averaging reference component to obtain VEP results. Results show the variance in the latency of the wireless marker messaging link is consistent enough to support the generation and recording of visual evoked potentials. The averaged sensor waveforms at multiple CPU speeds are presented and demonstrate suitability of the Bluetooth interface for portable ambulatory visual evoked potential implementation on our CAMAS platform.
Duncan, Jennifer M; Janke, E Amy; Kozak, Andrea T; Roehrig, Megan; Russell, Stephanie W; McFadden, H Gene; Demott, Andrew; Pictor, Alex; Hedeker, Don; Spring, Bonnie
2011-04-11
Obese adults struggle to make the changes necessary to achieve even modest weight loss, though a decrease in weight by as little as 10% can have significant health benefits. Failure to meet weight loss goals may in part be associated with barriers to obesity treatment. Wide-spread dissemination of evidence-based obesity treatment faces multiple challenges including cost, access, and implementing the programmatic characteristics on a large scale. The PDA+: A Personal Digital Assistant for Obesity Treatment randomized controlled trial (RCT) was designed to test whether a PDA-based behavioral intervention enhances the effectiveness of the existing group weight loss treatment program at VA Medical Centers Managing Overweight/Obese Veterans Everywhere (MOVE!). We also aim to introduce technology as a way to overcome systemic barriers of traditional obesity treatment. Veterans enrolled in the MOVE! group at the Hines Hospital VAMC with BMI ≥ 25 and ≤ 40 and weigh < 400 pounds, experience chronic pain (≥ 4 on the NRS-I scale for ≥ 6 months prior to enrollment) and are able to participate in a moderate intensity exercise program will be recruited and screened for eligibility. Participants will be randomized to receive either: a) MOVE! treatment alone (Standard Care) or b) Standard Care plus PDA (PDA+). Those randomized to PDA+ will record dietary intake, physical activity, and weight on the PDA. In addition, they will also record mood and pain intensity, and receive biweekly telephone support for the first 6-months of the 12-month study. All participants will attend in-person lab sessions every three months to complete questionnaires and for the collection of anthropomorphic data. Weight loss and decrease in pain level intensity are the primary outcomes. The PDA+ trial represents an important step in understanding ways to improve the use of technology in obesity treatment. The trial will address barriers to obesity care by implementing effective behavioral components of a weight loss intervention and delivering high intensity, low cost obesity treatment. This RCT also tests an intervention approach supported by handheld technology in a population traditionally considered to have lower levels of technology literacy. ClinicalTrials.gov: NCT00371462.
2011-06-01
Selected Security Features in BlackBerry and SME PED Devices...Figure 1, the blue bars represent the net present value (NPV) of costs for current DoD wireless services on the unclassified (e.g., BlackBerry ) and...PDA], Blackberry , iPhone, etc.) for both Battle Command applications and communications and secure data only that needs to be classified as part of
Product Pipeline: Megan K. Fox Looks at the Latest Ebook Devices and What They Mean for Librarians
ERIC Educational Resources Information Center
Fox, Megan K.
2006-01-01
The standalone PDA seems to be dying, but the prominence of smart phones and similar devices are opening new doors for ebooks. The digital music and ipod phenomena bode well for what could happen with e-text publishing, with content and hardware easier to use just as new open standards are beginning to emerge. Mobile, portable, wireless, handheld,…
Automobile inspection system based on wireless communication
NASA Astrophysics Data System (ADS)
Miao, Changyun; Ye, Chunqing
2010-07-01
This paper aims to research the Automobile Inspection System based on Wireless Communication, and suggests an overall design scheme which uses GPS for speed detection and Bluetooth and GPRS for communication. The communication between PDA and PC was realized by means of GPRS and TCP/IP; and the hardware circuit and software for detection terminal were devised by means of JINOU-3264 Bluetooth Module after analyzing the Bluetooth and its communication protocol. According to the results of debugging test, this system accomplished GPRS based data communication and management as well as the real-time detection on auto safety performance parameters in crash test via PC, whereby the need for mobility and reliability was met and the efficiency and level of detection was improved.
Wireless Content Repurposing Architecture for DC Command and Control
2003-09-01
was a natural choice as our primary mobile device for the DC investigators. 28 The Clie uses a Lithium Ion battery , which is the longest...projects the screen of the PDA on a head-mounted display maybe used. Battery life of PDAs is relatively short. This means many Lithium Ion...Mobile Devices Mobile devices such as PDAs, mobile phones, and Smartphones have become tightly interwoven as an important part of everyday lives
The Factors that Motivate and Hinder the Students with Hearing Impairment to Use Mobile Technology
ERIC Educational Resources Information Center
Kuzu, Abdullah
2011-01-01
This research which aims to find out the factors that motivate students with hearing impairment to use PDA (Personal Digital Assistant), a product of mobile technology, in instructional activities, interactions with their peers and instructors, and in their daily lives, and the factors that hinder these individuals from using PDA was designed as…
Real-time indoor monitoring system based on wireless sensor networks
NASA Astrophysics Data System (ADS)
Wu, Zhengzhong; Liu, Zilin; Huang, Xiaowei; Liu, Jun
2008-10-01
Wireless sensor networks (WSN) greatly extend our ability to monitor and control the physical world. It can collaborate and aggregate a huge amount of sensed data to provide continuous and spatially dense observation of environment. The control and monitoring of indoor atmosphere conditions represents an important task with the aim of ensuring suitable working and living spaces to people. However, the comprehensive air quality, which includes monitoring of humidity, temperature, gas concentrations, etc., is not so easy to be monitored and controlled. In this paper an indoor WSN monitoring system was developed. In the system several sensors such as temperature sensor, humidity sensor, gases sensor, were built in a RF transceiver board for monitoring indoor environment conditions. The indoor environmental monitoring parameters can be transmitted by wireless to database server and then viewed throw PC or PDA accessed to the local area networks by administrators. The system, which was also field-tested and showed a reliable and robust characteristic, is significant and valuable to people.
Matthew, Andrew G; Currie, Kristen L; Irvine, Jane; Ritvo, Paul; Santa Mina, Daniel; Jamnicky, Leah; Nam, Robert; Trachtenberg, John
2007-01-01
Background In clinical and research practice linked to prostate cancer treatment, frequent monitoring of patient health-related quality of life (HRQOL) is essential. Practical and analytic limitations of paper questionnaire data capture may be overcome with the use of self-administered personal digital assistant (PDA) data collection. The objective of this study was to assess the reliability, validity, and feasibility of using PDA in place of paper versions of the International Prostate Symptom Score (IPSS), the Patient Oriented Prostate Cancer Utility Survey (PORPUS), and the International Index of Erectile Function-5 (IIEF-5) in a prostate cancer clinic setting. Methods 152 participants were randomly assigned to one of three conditions: 1) paper followed by PDA survey; 2) PDA followed by paper survey; or 3) PDA followed by PDA survey. Evaluation included an assessment of data quality (internal consistency, test-retest reliability, response correlation, completeness of data), and feasibility (participation rates, time to completion, preference and difficultly/ease of using PDA). Results Internal consistency was similar for both PDA and paper applications. Test-retest reliability was confirmed for PDA repeated administration. Data from paper and PDA questionnaires were strongly correlated. Lower missed item rates were found in PDA administration. 82.8% of participants preferred using the PDA or had no preference. Mean difficulty/ease ratings indicated that participants found the PDA easy to use. Age did not significantly correlate with preference or difficulty. Conclusion The results confirm the adaptability of the IPSS, IIEF-5, and the PORPUS to PDA administration. Similarly, the findings of this study support the feasibility of using PDA technology for HRQOL serial data capture in the prostate cancer patient population. PMID:17617906
Deep-brain stimulator and control of Parkinson's disease
NASA Astrophysics Data System (ADS)
Varadan, Vijay K.; Harbaugh, Robert; Abraham, Jose K.
2004-07-01
The design of a novel feedback sensor system with wireless implantable polymer MEMS sensors for detecting and wirelessly transmitting physiological data that can be used for the diagnosis and treatment of various neurological disorders, such as Parkinson's disease, epilepsy, head injury, stroke, hydrocephalus, changes in pressure, patient movements, and tremors is presented in this paper. The sensor system includes MEMS gyroscopes, accelerometers, and pressure sensors. This feedback sensor system focuses on the development and integration of implantable systems with various wireless sensors for medical applications, particularly for the Parkinson's disease. It is easy to integrate and modify the sensor network feed back system for other neurological disorders mentioned above. The monitoring and control of tremor in Parkinson's disease can be simulated on a skeleton via wireless telemetry system communicating with electroactive polymer actuator, and microsensors attached to the skeleton hand and legs. Upon sensing any abnormal motor activity which represent the characteristic rhythmic motion of a typical Parkinson's (PD) patient, these sensors will generate necessary control pulses which will be transmitted to a hat sensor system on the skeleton head. Tiny inductively coupled antennas attached to the hat sensor system can receive these control pulses, demodulate and deliver it to actuate the parts of the skeleton to control the abnormal motor activity. This feedback sensor system can further monitor and control depending on the amplitude of the abnormal motor activity. This microsystem offers cost effective means of monitoring and controlling of neurological disorders in real PD patients. Also, this network system offers a remote monitoring of the patients conditions without visiting doctors office or hospitals. The data can be monitored using PDA and can be accessed using internet (or cell phone). Cellular phone technology will allow a health care worker to be automatically notified if monitoring indicates an emergency situation. The main advantage of such system is that it can effectively monitor large number of patients at the same time, which helps to compensate the present shortage of health care workers.
McCord, Gary; Pendleton, Brian F; Schrop, Susan Labuda; Weiss, Lisa; Stockton, LuAnne; Hamrich, Lynn M
2009-01-01
The effects of the use of technological devices on dimensions that affect the physician-patient relationship need to be well understood. Determine patients' perceptions of physicians' personal digital assistant (PDA) use, comparing the results across 8 physician-patient dimensions important to clinical interactions. Patients completed anonymous surveys about their perceptions of physician PDA use. Data were collected during 2006 and 2007 at 12 family medicine practices. Survey items included physician sex, patient demographics, if physicians explained why they were using the PDA, and Likert ratings on 8 dimensions of how a PDA can influence physician-patient interactions (surprise, confidence, feelings, comfort, communication, relationship, intelligence, and satisfaction). The survey response rate was 78%. Physicians explained to their patients what they were doing with the PDA 64% of the time. Logistic regression analyses determined that patients of male physicians, patients attending private practices and underserved sites, patients with Medicaid insurance, and patients who observed their physician using a PDA during both the index visit and at least one prior visit were more likely to receive an explanation of PDA use. Most importantly, physician-patient communication was rated significantly more positive if an explanation of PDA use was offered. Patients rate interactions with their physicians more positively when physicians explain their PDA use.
Performance and Mechanism of Uranium Adsorption from Seawater to Poly(dopamine)-Inspired Sorbents.
Wu, Fengcheng; Pu, Ning; Ye, Gang; Sun, Taoxiang; Wang, Zhe; Song, Yang; Wang, Wenqing; Huo, Xiaomei; Lu, Yuexiang; Chen, Jing
2017-04-18
Developing facile and robust technologies for effective enrichment of uranium from seawater is of great significance for resource sustainability and environmental safety. By exploiting mussel-inspired polydopamine (PDA) chemistry, diverse types of PDA-functionalized sorbents including magnetic nanoparticle (MNP), ordered mesoporous carbon (OMC), and glass fiber carpet (GFC) were synthesized. The PDA functional layers with abundant catechol and amine/imine groups provided an excellent platform for binding to uranium. Due to the distinctive structure of PDA, the sorbents exhibited multistage kinetics which was simultaneously controlled by chemisorption and intralayer diffusion. Applying the diverse PDA-modified sorbents for enrichment of low concentration (parts per billion) uranium in laboratory-prepared solutions and unpurified seawater was fully evaluated under different scenarios: that is, by batch adsorption for MNP and OMC and by selective filtration for GFC. Moreover, high-resolution X-ray photoelectron spectroscopic and extended X-ray absorption fine structure studies were performed for probing the underlying coordination mechanism between PDA and U(VI). The catechol hydroxyls of PDA were identified as the main bidentate ligands to coordinate U(VI) at the equatorial plane. This study assessed the potential of versatile PDA chemistry for development of efficient uranium sorbents and provided new insights into the interaction mechanism between PDA and uranium.
Gas Main Sensor and Communications Network System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hagen Schempf
Automatika, Inc. was contracted by the Department of Energy (DOE) and with co-funding from the Northeast Gas Association (NGA), to develop an in-pipe natural gas prototype measurement and wireless communications system for assessing and monitoring distribution networks. This projected was completed in April 2006, and culminated in the installation of more than 2 dozen GasNet nodes in both low- and high-pressure cast-iron and steel mains owned by multiple utilities in the northeastern US. Utilities are currently logging data (off-line) and monitoring data in real time from single and multiple networked sensors over cellular networks and collecting data using wireless bluetoothmore » PDA systems. The system was designed to be modular, using in-pipe sensor-wands capable of measuring, flow, pressure, temperature, water-content and vibration. Internal antennae allowed for the use of the pipe-internals as a waveguide for setting up a sensor network to collect data from multiple nodes simultaneously. Sensor nodes were designed to be installed with low- and no-blow techniques and tools. Using a multi-drop bus technique with a custom protocol, all electronics were designed to be buriable and allow for on-board data-collection (SD-card), wireless relaying and cellular network forwarding. Installation options afforded by the design included direct-burial and external polemounted variants. Power was provided by one or more batteries, direct AC-power (Class I Div.2) and solar-array. The utilities are currently in a data-collection phase and intend to use the collected (and processed) data to make capital improvement decisions, compare it to Stoner model predictions and evaluate the use of such a system for future expansion, technology-improvement and commercialization starting later in 2006.« less
2005-06-01
company has devel- oped an exciting prototype technology: … that lets users of PDAs and similar mobile devices put data into their handheld systems...for a class of small, easily carried electronic devices used to store and retrieve infor- mation” [2], were at one time viewed as lit- tle more than...some of the many ways that PDA technology is currently being used within the DoD: • The Pocket-Sized Forward Entry Device (PFED) is a ruggedized PDA
3D Medical Collaboration Technology to Enhance Emergency Healthcare
Welch, Greg; Sonnenwald, Diane H; Fuchs, Henry; Cairns, Bruce; Mayer-Patel, Ketan; Söderholm, Hanna M.; Yang, Ruigang; State, Andrei; Towles, Herman; Ilie, Adrian; Ampalam, Manoj; Krishnan, Srinivas; Noel, Vincent; Noland, Michael; Manning, James E.
2009-01-01
Two-dimensional (2D) videoconferencing has been explored widely in the past 15–20 years to support collaboration in healthcare. Two issues that arise in most evaluations of 2D videoconferencing in telemedicine are the difficulty obtaining optimal camera views and poor depth perception. To address these problems, we are exploring the use of a small array of cameras to reconstruct dynamic three-dimensional (3D) views of a remote environment and of events taking place within. The 3D views could be sent across wired or wireless networks to remote healthcare professionals equipped with fixed displays or with mobile devices such as personal digital assistants (PDAs). The remote professionals’ viewpoints could be specified manually or automatically (continuously) via user head or PDA tracking, giving the remote viewers head-slaved or hand-slaved virtual cameras for monoscopic or stereoscopic viewing of the dynamic reconstructions. We call this idea remote 3D medical collaboration. In this article we motivate and explain the vision for 3D medical collaboration technology; we describe the relevant computer vision, computer graphics, display, and networking research; we present a proof-of-concept prototype system; and we present evaluation results supporting the general hypothesis that 3D remote medical collaboration technology could offer benefits over conventional 2D videoconferencing in emergency healthcare. PMID:19521951
3D medical collaboration technology to enhance emergency healthcare.
Welch, Gregory F; Sonnenwald, Diane H; Fuchs, Henry; Cairns, Bruce; Mayer-Patel, Ketan; Söderholm, Hanna M; Yang, Ruigang; State, Andrei; Towles, Herman; Ilie, Adrian; Ampalam, Manoj K; Krishnan, Srinivas; Noel, Vincent; Noland, Michael; Manning, James E
2009-04-19
Two-dimensional (2D) videoconferencing has been explored widely in the past 15-20 years to support collaboration in healthcare. Two issues that arise in most evaluations of 2D videoconferencing in telemedicine are the difficulty obtaining optimal camera views and poor depth perception. To address these problems, we are exploring the use of a small array of cameras to reconstruct dynamic three-dimensional (3D) views of a remote environment and of events taking place within. The 3D views could be sent across wired or wireless networks to remote healthcare professionals equipped with fixed displays or with mobile devices such as personal digital assistants (PDAs). The remote professionals' viewpoints could be specified manually or automatically (continuously) via user head or PDA tracking, giving the remote viewers head-slaved or hand-slaved virtual cameras for monoscopic or stereoscopic viewing of the dynamic reconstructions. We call this idea remote 3D medical collaboration. In this article we motivate and explain the vision for 3D medical collaboration technology; we describe the relevant computer vision, computer graphics, display, and networking research; we present a proof-of-concept prototype system; and we present evaluation results supporting the general hypothesis that 3D remote medical collaboration technology could offer benefits over conventional 2D videoconferencing in emergency healthcare.
Chang, Polun; Tzeng, Yuann-Meei; Wu, Shiao-Chi; Sang, Ying-Yang; Chen, Shih-Shin
2003-01-01
An advanced PDA support system for the triage was designed to evaluate users inverted exclamation mark | acceptance of this system compared with a traditional terminal system. Davis inverted exclamation mark | Technology Acceptance Model was used to evaluate users inverted exclamation mark | acceptance. All 72 ER nurses in a 2700-bed medical center were invited for the study. The results showed that the PDA system was easier to operate than the terminal one, but had worse interface. The subjects showed significantly greater willingness to accept the terminal system instead of the PDA system. The comparative acceptance of PDA, compared with that of the old system, might still be marginally too low if its interface couldn inverted exclamation mark |t be improved or no other unique practical benefits could be verified.
Network-Oriented Radiation Monitoring System (NORMS)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rahmat Aryaeinejad; David F. Spencer
2007-10-01
We have developed a multi-functional pocket radiation monitoring system capable of detecting and storing gamma ray and neutron data and then sending the data through a wireless connection to a remote central facility upon request. The device has programmable alarm trigger levels that can be modified for specific applications. The device could be used as a stand-alone device or in conjunction with an array to cover a small or large area. The data is stored with a date/time stamp. The device may be remotely configured. Data can be transferred and viewed on a PDA via direct connection or wirelessly. Functional/benchmore » tests have been completed successfully. The device detects low-level neutron and gamma sources within a shielded container in a radiation field of 10 uR/hr above the ambient background level.« less
King, Kathryn; Wiebe, Michael
2011-01-01
CONFERENCE PROCEEDING Proceedings of the PDA/FDA Adventitious Viruses in Biologics: Detection and Mitigation Strategies Workshop in Bethesda, MD, USA; December 1-3, 2010 Guest Editors: Arifa Khan (Bethesda, MD), Patricia Hughes (Bethesda, MD) and Michael Wiebe (San Francisco, CA).
[The usefulness of personal digital assistants (Palm and Pocket PC) in the medical field].
Daher, Ralph; Awada, Hassane
2007-01-01
The Personal Digital Assistant (PDA) has become nowadays a powerful and essential tool for many physicians. Its promising success in the near future and the lack of information in regard to its use in Lebanon led to this transverse study. A questionnaire was submitted to the doctors, residents and interns of Hôtel-Dieu de France (HDF) Hospital (Beirut), during March-April 2004 in order to evaluate the use of PDAs, the preferences and the needs of the medical personnel and to propose solutions which can meet its needs. The answers' rate to the questionnaire is 70.3% (303 answers). The PDA possession rate is 3036%; it is significantly more important in physicians compared to surgeons. Among those having a PDA, the operating system Palm dominates with 60% with a current tendency towards the purchase of Pocket PC; the operating system Pocket PC dominates the Phone PDAs. Approximately one third use their PDA ineffectively and admit having difficulties which greatly reduce its use in the medical field. Lexi-Drugs is the most used pharmaceutical guide, Sanford Guide the most used microbiological guide, iSilo the most used medical textbooks reader. More than 85% do not use any program to follow up their patients or read medical journals. Two thirds recognize the beneficial role of the PDA on the quality and the speed of the medical practice, one third consider that it reduces medical errors. The availability of medical programs is significantly more important for Palm. Among the subjects not having a PDA, 47% hope to buy one in the year to come; the possession rate of PDAs is estimated to reach 69.3% in 2010. Computerization of the medical data, installation of a wireless network, courses on the use of PDAs in the medical field, etc., are needs considered to be useful by 60-80% of the responders. Many medical utilities are already computerized. They still have to be presented in a format compatible with PDAs to answer a great part of the needs. A guided hospital policy and an educational program are needed to increase the usefulness of PDAs in the medical field.
NASA Astrophysics Data System (ADS)
Prusten, Mark J.; McIntyre, Michelle; Landis, Marvin
2006-02-01
A 3D workflow pipeline is presented for High Dynamic Range (HDR) image capture of projected scenes or objects for presentation in CAVE virtual environments. The methods of HDR digital photography of environments vs. objects are reviewed. Samples of both types of virtual authoring being the actual CAVE environment and a sculpture are shown. A series of software tools are incorporated into a pipeline called CAVEPIPE, allowing for high-resolution objects and scenes to be composited together in natural illumination environments [1] and presented in our CAVE virtual reality environment. We also present a way to enhance the user interface for CAVE environments. The traditional methods of controlling the navigation through virtual environments include: glove, HUD's and 3D mouse devices. By integrating a wireless network that includes both WiFi (IEEE 802.11b/g) and Bluetooth (IEEE 802.15.1) protocols the non-graphical input control device can be eliminated. Therefore wireless devices can be added that would include: PDA's, Smart Phones, TabletPC's, Portable Gaming consoles, and PocketPC's.
Gentry, Tony; Kriner, Richard; Sima, Adam; McDonough, Jennifer; Wehman, Paul
2015-03-01
Personal digital assistants (PDAs) are versatile task organizers that hold promise as assistive technologies for people with cognitive-behavioral challenges. This delayed randomized controlled trial compared two groups of adult workers with autism spectrum disorder (ASD) to determine whether the use of an Apple iPod Touch PDA as a vocational support improves work performance and reduces personal support needs on the job. Baseline data were collected on 50 adults with ASD who were beginning a vocational placement supported by a job coach. Participants were randomized to receive training in the use of a PDA as a vocational aid upon starting their job or after working 12 weeks without PDA support. Workers who received PDA training at the beginning of their job placement required significantly less hours of job coaching support (p = 0.013) during their first 12 weeks on the job than those who had not yet received the intervention. Functional performance between the two groups was not significantly different. The significant difference in hours of job coaching support persisted during the subsequent 12 weeks, in which both groups used a PDA (p = 0.017).
Advancing from offline to online activity recognition with wearable sensors.
Ermes, Miikka; Parkka, Juha; Cluitmans, Luc
2008-01-01
Activity recognition with wearable sensors could motivate people to perform a variety of different sports and other physical exercises. We have earlier developed algorithms for offline analysis of activity data collected with wearable sensors. In this paper, we present our current progress in advancing the platform for the existing algorithms to an online version, onto a PDA. Acceleration data are obtained from wireless motion bands which send the 3D raw acceleration signals via a Bluetooth link to the PDA which then performs the data collection, feature extraction and activity classification. As a proof-of-concept, the online activity system was tested with three subjects. All of them performed at least 5 minutes of each of the following activities: lying, sitting, standing, walking, running and cycling with an exercise bike. The average second-by-second classification accuracies for the subjects were 99%, 97%, and 82 %. These results suggest that earlier developed offline analysis methods for the acceleration data obtained from wearable sensors can be successfully implemented in an online activity recognition application.
Wireless Networks: New Meaning to Ubiquitous Computing.
ERIC Educational Resources Information Center
Drew, Wilfred, Jr.
2003-01-01
Discusses the use of wireless technology in academic libraries. Topics include wireless networks; standards (IEEE 802.11); wired versus wireless; why libraries implement wireless technology; wireless local area networks (WLANs); WLAN security; examples of wireless use at Indiana State University and Morrisville College (New York); and useful…
ERIC Educational Resources Information Center
Dodds, Richard; Mason, Christine Y.
2005-01-01
Although cell phones keep kids in touch with families and personal digital assistants (PDA's) help organize assignments and give Internet access, when they are added to the school climate, educators must reassess policies so technology does not interfere with instruction time. This article discusses the several effects of cell phones to K-6…
Sahler, Olle Jane Z.; Sherman, Sandra A.; Fairclough, Diane L.; Butler, Robert W.; Katz, Ernest R.; Dolgin, Michael J.; Varni, James W.; Noll, Robert B.; Phipps, Sean
2009-01-01
Objectives To evaluate the feasibility and efficacy of a handheld personal digital assistant (PDA)-based supplement for maternal Problem-Solving Skills Training (PSST) and to explore Spanish-speaking mothers’ experiences with it. Methods Mothers (n = 197) of children with newly diagnosed cancer were randomized to traditional PSST or PSST + PDA 8-week programs. Participants completed the Social Problem-Solving Inventory-Revised, Beck Depression Inventory-II, Profile of Mood States, and Impact of Event Scale-Revised pre-, post-treatment, and 3 months after completion of the intervention. Mothers also rated optimism, logic, and confidence in the intervention and technology. Results Both groups demonstrated significant positive change over time on all psychosocial measures. No between-group differences emerged. Despite technological “glitches,” mothers expressed moderately high optimism, appreciation for logic, and confidence in both interventions and rated the PDA-based program favorably. Technology appealed to all Spanish-speaking mothers, with younger mothers showing greater proficiency. Conclusions Well-designed, supported technology holds promise for enhancing psychological interventions. PMID:19091804
Wireless technologies for robotic endoscope in gastrointestinal tract.
Gao, P; Yan, G; Wang, Z; Liu, H
2012-07-01
This paper introduces wireless technologies for use with robotic endoscopes in the gastrointestinal tract. The technologies include wireless power transmission (WPT), wireless remote control (WRC), and wireless image transmission (WIT). WPT, based on the electromagnetic coupling principle, powers active locomotion actuators and other peripherals in large air gaps. WRC, based on real-time bidirectional communication, has a multikernel frame in vivo to realize real-time multitasking. WIT provides a continuous dynamic image with a revolution of 320 × 240 pixel at 30 fps for in vitro diagnosis. To test these wireless technologies, three robotic endoscope prototypes were fabricated and equipped with the customized modules. The experimental results show that the wireless technologies have value for clinical applications.
The wireless Web and patient care.
Bergeron, B P
2001-01-01
Wireless computing, when integrated with the Web, is poised to revolutionize the practice and teaching of medicine. As vendors introduce wireless Web technologies in the medical community that have been used successfully in the business and consumer markets, clinicians can expect profound increases in the amount of patient data, as well as the ease with which those data are acquired, analyzed, and disseminated. The enabling technologies involved in this transformation to the wireless Web range from the new generation of wireless PDAs, eBooks, and wireless data acquisition peripherals to new wireless network protocols. The rate-limiting step in the application of this technology in medicine is not technology per se but rather how quickly clinicians and their patients come to accept and appreciate the benefits and limitations of the application of wireless Web technology.
Enabling Logistics With Portable and Wireless Technology Study. Volume 1
2004-08-06
Project”, Ubiquitous Computing Group Microsoft Research, 2001. 102 Enabling Logistics with Portable and Wireless Technology Study ...Enabling Logistics with Portable and Wireless Technology Study Final Report FINAL REPORT...Volume I) Enabling Logistics with Portable and Wireless Technology Study AUTHORS School of Industrial Engineering Dr. Soundar Kumara
NASA Astrophysics Data System (ADS)
Huo, Zongliang; Jin, Lei; Han, Yulong; Li, Xinkai; Ye, Tianchun; Liu, Ming
2015-01-01
The influence of post-deposition annealing (PDA) temperature condition on charge distribution behavior of HfO2 thin films was systematically investigated by various-temperature Kelvin probe force microscopy technology. Contact potential difference profiles demonstrated that charge storage capability shrinks with decreasing annealing temperature from 1,000 to 500 °C and lower. Compared to 1,000 °C PDA, it was found that 500 °C PDA causes deeper effective trap energy level, suppresses lateral charge spreading, and improves the retention characteristics. It is concluded that low-temperature PDA can be adopted in 3D HfO2-based charge trap flash memory to improve the thermal treatment compatibility of the bottom peripheral logic and upper memory arrays.
Wireless body sensor networks for health-monitoring applications.
Hao, Yang; Foster, Robert
2008-11-01
Current wireless technologies, such as wireless body area networks and wireless personal area networks, provide promising applications in medical monitoring systems to measure specified physiological data and also provide location-based information, if required. With the increasing sophistication of wearable and implantable medical devices and their integration with wireless sensors, an ever-expanding range of therapeutic and diagnostic applications is being pursued by research and commercial organizations. This paper aims to provide a comprehensive review of recent developments in wireless sensor technology for monitoring behaviour related to human physiological responses. It presents background information on the use of wireless technology and sensors to develop a wireless physiological measurement system. A generic miniature platform and other available technologies for wireless sensors have been studied in terms of hardware and software structural requirements for a low-cost, low-power, non-invasive and unobtrusive system.
NASA Astrophysics Data System (ADS)
Zhu, Kairuo; Lu, Songhua; Gao, Yang; Zhang, Rui; Tan, Xiaoli; Chen, Changlun
2017-02-01
Novel hierarchical core/shell structured polydopamine@MgAl-layered double hydroxides (PDA@MgAl-LDHs) composites involving MgAl-layered double hydroxide shells and PDA cores were fabricated thought one-pot coprecipitation assembly and methodically characterized by X-ray diffraction, Fourier transformed infrared spectroscopy, scanning/transmission electron microscopy, selected area electron diffraction, elemental mapping, thermogravimetric analysis and X-ray photoelectron spectroscopy technologies. U(VI) and Eu(III) sorption experiments showed that the PDA@MgAl-LDHs exhibited higher sorption ability with a maximum sorption capacity of 142.86 and 76.02 mg/g at 298 K and pH 4.5, respectively. More importantly, according to XPS analyses, U(VI) and Eu(III) were sorbed on PDA@MgAl-LDHs via oxygen-containing functional groups, and the chemical affinity of U(VI) by oxygen-containing functional groups is higher than that of Eu(III). These observations show great expectations in the enrichment of radionuclides from aquatic environments by PDA@MgAl-LDHs.
Zahn, Evan M; Nevin, Phillip; Simmons, Charles; Garg, Ruchira
2015-02-01
To describe a new technique for transcatheter patent ductus arteriosus (PDA) closure in extremely preterm infants using commercially available technology. PDA in premature neonates continues to be a significant clinical problem contributing importantly to both morbidity and mortality. Surgical ligation and medical therapy both have their drawbacks. Hospital records and catheterization reports of all premature neonates (< 32 weeks gestation) who underwent transcatheter PDA closure between March 2013 and February 2014 were reviewed. Particular attention was paid to procedural details, complications, and short and mid-term outcomes. Six premature infants born at gestational ages ranging between 26 and 31 weeks (median, 26 weeks) underwent attempted transcatheter PDA closure using the Amplatzer Vascular Plug II (AVP II). Median age and weight was 21.5 days (16-80 days) and 1,180 g (870-2,240 g), respectively. Fluoroscopy and echocardiography were used to guide device. Contrast angiography was not used in any patient. Complete closure was achieved in all patients with no major procedural complications. Median fluoroscopy and procedural times were 9.4 (0-19.5) and 51.5 (33-87) min, respectively. All patients were alive at the time of this report. There were no instances of device migration, left pulmonary artery (LPA), or aortic coarctation. This preliminary study demonstrates that transcatheter PDA closure can be successfully performed in extremely preterm neonates using currently available technology with a high success rate and a low incidence of complications. This report also describes a novel transvenous approach using a combination of echocardiography and judicious use of fluoroscopy to avoid arterial access in this fragile patient population. © 2014 Wiley Periodicals, Inc. © 2014 Wiley Periodicals, Inc.
Wang, Xinheng
2008-01-01
Wireless telemedicine using GSM and GPRS technologies can only provide low bandwidth connections, which makes it difficult to transmit images and video. Satellite or 3G wireless transmission provides greater bandwidth, but the running costs are high. Wireless networks (WLANs) appear promising, since they can supply high bandwidth at low cost. However, the WLAN technology has limitations, such as coverage. A new wireless networking technology named the wireless mesh network (WMN) overcomes some of the limitations of the WLAN. A WMN combines the characteristics of both a WLAN and ad hoc networks, thus forming an intelligent, large scale and broadband wireless network. These features are attractive for telemedicine and telecare because of the ability to provide data, voice and video communications over a large area. One successful wireless telemedicine project which uses wireless mesh technology is the Emergency Room Link (ER-LINK) in Tucson, Arizona, USA. There are three key characteristics of a WMN: self-organization, including self-management and self-healing; dynamic changes in network topology; and scalability. What we may now see is a shift from mobile communication and satellite systems for wireless telemedicine to the use of wireless networks based on mesh technology, since the latter are very attractive in terms of cost, reliability and speed.
Capacity Building for Research and Education in GIS/GPS Technology and Systems
2015-05-20
In multi- sensor area Wireless Sensor Networking (WSN) fields will be explored. As a step forward the research to be conducted in WSN field is to...Agriculture Using Technology for Crops Scouting in Agriculture Application of Technology in Precision Agriculture Wireless Sensor Network (WSN) in...Cooperative Engagement Capability Range based algorithms for Wireless Sensor Network Self-configurable Wireless Sensor Network Energy Efficient Wireless
ERIC Educational Resources Information Center
Jaspan, Heather B.; Flisher, Alan J.; Myer, Landon; Mathews, Catherine; Seebregts, Chris; Berwick, Jessica R.; Wood, Robin; Bekker, Linda-Gail
2007-01-01
Reporting bias in adolescent behavioural research may be overcome with the use of personal digital assistants (PDA) or other computer based technologies. However, there is little insight into the use of these tools among adolescents in low resource settings. We compared self-administered paper questionnaires with PDA questionnaires to collect…
ERIC Educational Resources Information Center
Fowles, Eileen R.; Gentry, Breine
2008-01-01
Objectives: To determine the feasibility of using personal digital assistant (PDA)-based technology for tracking and analysis of food intake in low-income pregnant women. Design: Descriptive. Participants provided an initial 24-hour dietary recall and recorded their food intake using a PDA-based software program for 2 days. Setting: Recruitment…
Implementation of a dynamic data entry system for the PHENIX gas system
NASA Astrophysics Data System (ADS)
Hagiwara, Masako
2003-10-01
The PHENIX detector at the BNL RHIC facility uses multiple detector technologies that require a precise gas delivery system, including flammable gases that require additional monitoring. During operation of the detector, it is crucial to maintain stable and safe operating conditions by carefully monitoring flows, pressures, and various other gas properties. These systems are monitored during running periods on a continuous basis. For the most part, these records were kept by hand, filling out a paper logsheet every four hours. A dynamic data entry system was needed to replace the paper logsheets. The solution created was to use a PDA or laptop computer with a wireless connection to enter the data directly into a MySQL database. The system uses PHP to dynamically create and update the data entry pages. The data entered can be viewed in graphs as well as tables. As a result, the data recorded will be easily accessible during PHENIX's next running period. It also allows for long term archiving, making the data available during the analysis phase, providing knowledge of the operating conditions of the gas system.
The Use of Mobile-Wireless Technology for Education.
ERIC Educational Resources Information Center
Altalib, Hasan
This paper focuses on the use of mobile-wireless technology for education. The first section is an introduction which provides a definition of the terms. The second section discusses implementation of mobile-wireless technology in schools, providing examples from Latrobe Junior High School, where wireless laptops were issued to students and River…
Value of wireless personal digital assistants for practice: perceptions of advanced practice nurses.
Garrett, Bernard; Klein, Gerri
2008-08-01
The aims were to explore advanced practice nurses' perceptions on wireless Personal Digital Assistant technologies, to establish the type and range of tools that would be useful to support their practice and to identify any requirements and limitations that may impact the implementation of wireless Personal Digital Assistants in practice. The wireless Personal Digital Assistant is becoming established as a hand-held computing tool for healthcare professionals. The reflections of advanced practice nurses' about the value of wireless Personal Digital Assistants and its potential to contribute to improved patient care has not been investigated. A qualitative interpretivist design was used to explore advanced practice nurses' perceptions on the value of wireless Personal Digital Assistant technologies to support their practice. The data were collected using survey questionnaires and individual and focus group interviews with nurse practitioners, clinical nurse specialists and information technology managers based in British Columbia, Canada. An open-coding content analysis was performed using qualitative data analysis software. Wireless Personal Digital Assistant's use supports the principles of pervasivity and is a technology rapidly being adopted by advanced practice nurses. Some nurses indicated a reluctance to integrate wireless Personal Digital Assistant technologies into their practices because of the cost and the short technological life cycle of these devices. Many of the barriers which precluded the use of wireless networks within facilities are being removed. Nurses demonstrated a complex understanding of wireless Personal Digital Assistant technologies and gave good rationales for its integration in their practice. Nurses identified improved client care as the major benefit of this technology in practice and the type and range of tools they identified included clinical reference tools such as drug and diagnostic/laboratory reference applications and wireless communications. Nurses in this study support integrating wireless mobile computing technologies into their practice to improve client care.
Wireless Instrumentation Use on Launch Vehicles
NASA Technical Reports Server (NTRS)
Sherman, Aaron
2010-01-01
This slide presentation reviews the results of a study on the use of wireless instrumentation and sensors on future launch vehicles. The use of wireless technologies would if feasible would allow for fewer wires, and allow for more flexibility. However, it was generally concluded that wireless solutions are not currently ready to replace wired technologies for launch vehicles. The recommendations of the study were to continue to use wired sensors as the primary choice for vehicle instrumentation, and to continue to assess needs and use wireless instrumentation where appropriate. The future work includes support efforts for wireless technologies, and continue to monitor the development of wireless solutions.
Authomatization of Digital Collection Access Using Mobile and Wireless Data Terminals
NASA Astrophysics Data System (ADS)
Leontiev, I. V.
Information technologies become vital due to information processing needs, database access, data analysis and decision support. Currently, a lot of scientific projects are oriented on database integration of heterogeneous systems. The problem of on-line and rapid access to large integrated systems of digital collections is also very important. Usually users move between different locations, either at work or at home. In most cases users need an efficient and remote access to information, stored in integrated data collections. Desktop computers are unable to fulfill the needs, so mobile and wireless devices become helpful. Handhelds and data terminals are nessessary in medical assistance (they store detailed information about each patient, and helpful for nurses), immediate access to data collections is used in a Highway patrol services (databanks of cars, owners, driver licences). Using mobile access, warehouse operations can be validated. Library and museum items cyclecounting will speed up using online barcode-scanning and central database access. That's why mobile devices - cell phones, PDA, handheld computers with wireless access, WindowsCE and PalmOS terminals become popular. Generally, mobile devices have a relatively slow processor, and limited display capabilities, but they are effective for storing and displaying textual data, recognize user hand-writing with stylus, support GUI. Users can perform operations on handheld terminal, and exchange data with the main system (using immediate radio access, or offline access during syncronization process) for update. In our report, we give an approach for mobile access to data collections, which raises an efficiency of data processing in a book library, helps to control available books, books in stock, validate service charges, eliminate staff mistakes, generate requests for book delivery. Our system uses mobile devices Symbol RF (with radio-channel access), and data terminals Symbol Palm Terminal for batch-processing and synchronization with remote library databases. We discuss the use of PalmOS-compatible devices, and WindowsCE terminals. Our software system is based on modular, scalable three-tier architecture. Additional functionality can be easily customized. Scalability is also supplied by Internet / Intranet technologies, and radio-access points. The base module of the system supports generic warehouse operations: cyclecounting with handheld barcode-scanners, efficient items delivery and issue, item movement, reserving, report generating on finished and in-process operations. Movements are optimized using worker's current location, operations are sorted in a priority order and transmitted to mobile and wireless worker's terminals. Mobile terminals improve of tasks processing control, eliminate staff mistakes, display actual information about main processes, provide data for online-reports, and significantly raise the efficiency of data exchange.
ERIC Educational Resources Information Center
Moriarty, Laura Joyce
2001-01-01
Discusses the use of wireless technology on college campuses. Explores why colleges may want to use the technology, when they should begin to take it seriously, the culture pushing the change, and how schools should approach wireless technology. (EV)
Xu, Qi; Hu, Dingyin; Duan, Bingyu; He, Jiping
2015-07-01
Epidural spinal cord stimulation (ESCS) combined with partial weight-bearing therapy (PWBT) has been shown to facilitate recovery of functional walking for individuals after spinal cord injury (SCI). The investigation of neural mechanisms of recovery from SCI under this treatment has been conducted broadly in rodent models, yet a suitable ESCS system is still unavailable. This paper describes a practical, programmable, and fully implantable stimulator for laboratory research on rats to explore fundamental neurophysiological principles for functional recovery after SCI. The ESCS system is composed of a personal digital assistant (PDA), an external controller, an implantable pulse generator (IPG), lead extension, and stimulating electrodes. The stimulation parameters can be programmed and adjusted through a graphical user interface on the PDA. The external controller is placed on the rat back and communicates with the PDA via radio-frequency (RF) telemetry. An RF carrier from the class-E power amplifier in the external controller provides both data and power for the IPG through an inductive link. The IPG is built around a microcontroller unit to generate voltage-regulated pulses delivered to the bipolar electrode for ESCS in rats. The encapsulated IPG measures 22 mm × 23 mm × 7 mm with a mass of ∼ 3.78 g. This fully implantable batteryless stimulator provided a simplified and efficient method to carry out chronic experiments in untethered animals for medical electro-neurological research.
New Methods and Models in Wireless Networks: Multigraphs--Games--Mechanism Design
ERIC Educational Resources Information Center
Tran, Dung Trung
2010-01-01
The recent evolution of wireless technology makes wireless devices ever more powerful and intelligent. One trend is that wireless devices are becoming more inexpensive and more diverse. As a result, new technologies make it possible to equip wireless nodes with several radio transmitters/receivers. Each radio may support multiple channels which…
Torre, D M; Sebastian, J L; Simpson, D E
2005-09-01
Cardiac auscultation is an important skill for medical students to master but students' exposure to cardiac auscultation is often unmonitored. The objective of this study was to gather data at the point of care about students' cardiac auscultation experience on a required medicine rotation using a Personal Digital Assistant (PDA) 'murmur form'. During an eight-month period, 120 M3 students used the authors' PDA-based learning tool to record information on 940 heart sounds and murmurs. Some 93% of all heart sounds/murmurs reported by students were verified by either a faculty member (56%) or a supervising resident (43%). A PDA can be a useful tool to monitor students' experiences of cardiac auscultation and to track direct observation of such skills by faculty or residents. Medical students are eager to use technology at the point of care to practice their clinical skills.
Mobilize Your instruction Program with Wireless Technology.
ERIC Educational Resources Information Center
Mathias, Molly Susan; Heser, Steven
2002-01-01
Describes the use of wireless technology for library bibliographic instruction at the Milwaukee Area Technical College. Highlights include a wireless mobile cart that holds laptop computers; faculty support; future plans; and recommendations, including investigating technology infrastructure and marketing. (LRW)
Wireless Technology in K-12 Education
ERIC Educational Resources Information Center
Walery, Darrell
2004-01-01
Many schools begin implementing wireless technology slowly by creating wireless "hotspots" on the fly. This is accomplished by putting a wireless access point on a cart along with a set of wireless laptop computers. A teacher can then wheel the cart anywhere in the school that has a network drop, plug the access point in and have an…
47 CFR 51.5 - Terms and definitions.
Code of Federal Regulations, 2010 CFR
2010-10-01
... technologies include, but are not limited to, traditional or new cable plant, wireless technologies, and power..., that maintains a collocation arrangement in an incumbent LEC wire center, with active electrical power... wireless service. A mobile wireless service is any mobile wireless telecommunications service, including...
[Advances in sensor node and wireless communication technology of body sensor network].
Lin, Weibing; Lei, Sheng; Wei, Caihong; Li, Chunxiang; Wang, Cang
2012-06-01
With the development of the wireless communication technology, implantable biosensor technology, and embedded system technology, Body Sensor Network (BSN) as one branch of wireless sensor networks and important part of the Internet of things has caught more attention of researchers and enterprises. This paper offers the basic concept of the BSN and analyses the related research. We focus on sensor node and wireless communication technology from perspectives of technology challenges, research advance and development trend in the paper. Besides, we also present a relative overview of domestic and overseas projects for the BSN.
Li, Ya-Pin; Gao, Hong-Wei; Fan, Hao-Jun; Wei, Wei; Xu, Bo; Dong, Wen-Long; Li, Qing-Feng; Song, Wen-Jing; Hou, Shi-Ke
2017-12-01
The objective of this study was to build a database to collect infectious disease information at the scene of a disaster through the use of 128 epidemiological questionnaires and 47 types of options, with rapid acquisition of information regarding infectious disease and rapid questionnaire customization at the scene of disaster relief by use of a personal digital assistant (PDA). SQL Server 2005 (Microsoft Corp, Redmond, WA) was used to create the option database for the infectious disease investigation, to develop a client application for the PDA, and to deploy the application on the server side. The users accessed the server for data collection and questionnaire customization with the PDA. A database with a set of comprehensive options was created and an application system was developed for the Android operating system (Google Inc, Mountain View, CA). On this basis, an infectious disease information collection system was built for use at the scene of disaster relief. The creation of an infectious disease information collection system and rapid questionnaire customization through the use of a PDA was achieved. This system integrated computer technology and mobile communication technology to develop an infectious disease information collection system and to allow for rapid questionnaire customization at the scene of disaster relief. (Disaster Med Public Health Preparedness. 2017;11:668-673).
Evaluation of wireless Local Area Networks
NASA Astrophysics Data System (ADS)
McBee, Charles L.
1993-09-01
This thesis is an in-depth evaluation of the current wireless Local Area Network (LAN) technologies. Wireless LAN's consist of three technologies: they are infrared light, microwave, and spread spectrum. When the first wireless LAN's were introduced, they were unfavorably labeled slow, expensive, and unreliable. The wireless LAN's of today are competitively priced, more secure, easier to install, and provide equal to or greater than the data throughput of unshielded twisted pair cable. Wireless LAN's are best suited for organizations that move office staff frequently, buildings that have historical significance, or buildings that have asbestos. Additionally, an organization may realize a cost savings of between $300 to $1,200 each time a node is moved. Current wireless LAN technologies have a positive effect on LAN standards being developed by the Defense Information System Agency (DISA). DoD as a whole is beginning to focus on wireless LAN's and mobile communications. If system managers want to remain successful, they need to stay abreast of this technology.
Technology Acceptance Model for Wireless Internet.
ERIC Educational Resources Information Center
Lu, June; Yu, Chun-Sheng; Liu, Chang; Yao, James E.
2003-01-01
Develops a technology acceptance model (TAM) for wireless Internet via mobile devices (WIMD) and proposes that constructs, such as individual differences, technology complexity, facilitating conditions, social influences, and wireless trust environment determine user-perceived short and long-term usefulness, and ease of using WIMD. Twelve…
DataPlay's mobile recording technology
NASA Astrophysics Data System (ADS)
Bell, Bernard W., Jr.
2002-01-01
A small rotating memory device which utilizes optical prerecorded and writeable technology to provide a mobile recording technology solution for digital cameras, cell phones, music players, PDA's, and hybrid multipurpose devices have been developed. This solution encompasses writeable, read only, and encrypted storage media.
... scientific issues related to RF exposure from wireless communications technology from an international perspective. Specific topics addressed have included: health effects of emerging wireless technologies recent biological ... - Wireless FAQs Federal Communications Commission - Radiofrequency Safety ...
Bluetooth low energy: wireless connectivity for medical monitoring.
Omre, Alf Helge
2010-03-01
Electronic wireless sensors could cut medical costs by enabling physicians to remotely monitor vital signs such as blood pressure, blood glucose, and blood oxygenation while patients remain at home. According to the IDC report "Worldwide Bluetooth Semiconductor 2008-2012 Forecast," published November 2008, a forthcoming radio frequency communication ("wireless connectivity") standard, Bluetooth low energy, will link wireless sensors via radio signals to the 70% of cell phones and computers likely to be fitted with the next generation of Bluetooth wireless technology, leveraging a ready-built infrastructure for data transmission. Analysis of trends indicated by this data can help physicians better manage diseases such as diabetes. The technology also addresses the concerns of cost, compatibility, and interoperability that have previously stalled widespread adoption of wireless technology in medical applications. (c) 2010 Diabetes Technology Society.
NASA Astrophysics Data System (ADS)
Liu, Zhi Feng; Wang, Ying; Huang, Dong Hui
2018-06-01
In the wake of big data and Internet plus era, continuous infiltration of digital technology has been happening in various fields of social and economic development. As the most important material carrier of historical culture, the historical value of historical buildings is produced and accumulated in its historical evolution, and it can only be protected from being created again. Based on the background of digitization of cultural resources, this paper summarizes the relevant digital technologies for the digital translation of information on buildings of historical and cultural heritage, as a means to promote the spread of the PDA+APPS mobile terminal, so as to achieve the purpose of preservation, protection, management and publicity. Meanwhile, this paper analyzes the application of digital technology in this field and the prospect of its function.
Partnership Opportunities with AFRC for Wireless Systems Flight Testing
NASA Technical Reports Server (NTRS)
Hang, Richard
2015-01-01
The presentation will overview the flight test capabilities at NASA Armstrong Flight Research Center (AFRC), to open up partnership collaboration opportunities for Wireless Community to conduct flight testing of aerospace wireless technologies. Also, it will brief the current activities on wireless sensor system at AFRC through SBIR (Small Business Innovation Research) proposals, and it will show the current areas of interest on wireless technologies that AFRC would like collaborate with Wireless Community to further and testing.
[Wireless device for monitoring the patients with chronic disease].
Ciorap, R; Zaharia, D; Corciovă, C; Ungureanu, Monica; Lupu, R; Stan, A
2008-01-01
Remote monitoring of chronic diseases can improve health outcomes and potentially lower health care costs. The high number of the patients, suffering of chronically diseases, who wish to stay at home rather then in a hospital increasing the need of homecare monitoring and have lead to a high demand of wearable medical devices. Also, extended patient monitoring during normal activity has become a very important target. In this paper are presented the design of the wireless monitoring devices based on ultra low power circuits, high storage memory flash, bluetooth communication and the firmware for the management of the monitoring device. The monitoring device is built using an ultra low power microcontroller (MSP430 from Texas Instruments) that offers the advantage of high integration of some circuits. The custom made electronic boards used for biosignal acquisition are also included modules for storage device (SD/MMC card) with FAT32 file system and Bluetooth device for short-range communication used for data transmission between monitoring device and PC or PDA. The work was focused on design and implementation of an ultra low power wearable device able to acquire patient vital parameters, causing minimal discomfort and allowing high mobility. The proposed wireless device could be used as a warning system for monitoring during normal activity.
NASA Astrophysics Data System (ADS)
Gunes-Lasnet, Sev; Dufour, Jean-Francois
2012-08-01
The potential uses and benefits of wireless technologies in space are very broad. Since many years the CCSDS SOIS wireless working group has worked at the identification of key applications for which wireless would bring benefits, and at supporting the deployment of wireless in space thanks to documents, in particular a Green informative book and magenta books presenting recommended practices.The Smart Sensor Inter-Agency Research Test bench (SSIART) is being designed to provide the space Agencies and the Industry with a reference smart sensor platform to test wireless sensor technologies in reference representative applications and RF propagation environments, while promoting these technologies at the same time.
Evaluation of Communication Alternatives for Intelligent Transportation Systems
DOT National Transportation Integrated Search
2010-08-31
The primary focus of this study involved developing a process for the evaluation of wireless technologies : for intelligent transportation systems, and for conducting experiments of potential wireless technologies : and topologies. Two wireless techn...
A survey of personal digital assistant use in a sample of New Zealand doctors.
Menzies, Oliver H; Thwaites, John
2012-03-30
To gather information about handheld computing hardware and software usage by hospital based doctors in New Zealand (NZ). An online tool (SurveyMonkey) was used to conduct the survey from 27 June to 10 September 2010. Distribution of the survey was via an email to all NZ District Health Boards (DHBs). There were 850 responses. About half of respondents (52%) used a personal digital assistant (PDA), 90% using it at least once daily. Usage varied greatly between DHBs (27-100%), perhaps related to institutional support. Among PDA users, the most common applications were the non-clinical; Scheduler (95%), Contacts (97%), and Tasks (83%). Users felt PDAs helped considerably with organisation and time saving. For non-users there were a range of barriers to usage, cost being a large factor. Another major barrier identified by both users and non-users was lack of organisational integration and support. Half of survey respondents used a PDA. PDA usage of responders from different DHBs varied considerably. Perceived barriers to PDA use included cost and lack of institutional support. A collaborative approach between clinical leadership and Information Technology teams to address barriers may result in increased utility and usage of PDAs in the NZ health system.
Practice brief. Securing wireless technology for healthcare.
Retterer, John; Casto, Brian W
2004-05-01
Wireless networking can be a very complex science, requiring an understanding of physics and the electromagnetic spectrum. While the radio theory behind the technology can be challenging, a basic understanding of wireless networking can be sufficient for small-scale deployment. Numerous security mechanisms are available to wireless technologies, making it practical, scalable, and affordable for healthcare organizations. The decision on the selected security model should take into account the needs for additional server hardware and administrative costs. Where wide area network connections exist between cooperative organizations, deployment of a distributed security model can be considered to reduce administrative overhead. The wireless approach chosen should be dynamic and concentrate on the organization's specific environmental needs. Aspects of organizational mission, operations, service level, and budget allotment as well as an organization's risk tolerance are all part of the balance in the decision to deploy wireless technology.
Mupparapu, Muralidhar
2006-02-15
Wireless networking is not new to contemporary dental offices around the country. Wireless routers and network cards have made access to patient records within the office handy and, thereby, saving valuable chair side time and increasing productivity. As is the case with any rapidly developing technology, wireless technology also changes with the same rate. Unless, the users of the wireless networking understand the implications of these changes and keep themselves updated periodically, the office network will become obsolete very quickly. This update of the emerging security protocols and pertaining to ratified wireless 802.11 standards will be timely for the contemporary dentist whose office is wirelessly networked. This article brings the practicing dentist up-to-date on the newer versions and standards in wireless networking that are changing at a fast pace. The introduction of newer 802.11 standards like super G, Super AG, Multiple Input Multiple Output (MIMO), and pre-n are changing the pace of adaptation of this technology. Like any other rapidly transforming technology, information pertaining to wireless networking should be a priority for the contemporary dentist, an eventual end-user in order to be a well-informed and techno-savvy consumer.
The Role of Wireless Computing Technology in the Design of Schools.
ERIC Educational Resources Information Center
Nair, Prakash
This document discusses integrating computers logically and affordably into a school building's infrastructure through the use of wireless technology. It begins by discussing why wireless networks using mobile computers are preferable to desktop machines in each classoom. It then explains the features of a wireless local area network (WLAN) and…
Liang, Jiajie; Huang, Lu; Li, Na; Huang, Yi; Wu, Yingpeng; Fang, Shaoli; Oh, Jiyoung; Kozlov, Mikhail; Ma, Yanfeng; Li, Feifei; Baughman, Ray; Chen, Yongsheng
2012-05-22
Although widely investigated, novel electromechanical actuators with high overall actuation performance are still in urgent need for various practical and scientific applications, such as robots, prosthetic devices, sensor switches, and sonar projectors. In this work, combining the properties of unique environmental perturbations-actuated deformational isomerization of polydiacetylene (PDA) and the outstanding intrinsic features of graphene together for the first time, we design and fabricate an electromechanical bimorph actuator composed of a layer of PDA crystal and a layer of flexible graphene paper through a simple yet versatile solution approach. Under low applied direct current (dc), the graphene-PDA bimorph actuator with strong mechanical strength can generate large actuation motion (curvature is about 0.37 cm(-1) under a current density of 0.74 A/mm(2)) and produce high actuation stress (more than 160 MPa/g under an applied dc of only 0.29 A/mm(2)). When applying alternating current (ac), this actuator can display reversible swing behavior with long cycle life under high frequencies even up to 200 Hz; significantly, while the frequency and the value of applied ac and the state of the actuators reach an appropriate value, the graphene-PDA actuator can produce a strong resonance and the swing amplitude will jump to a peak value. Moreover, this stable graphene-PDA actuator also demonstrates rapidly and partially reversible electrochromatic phenomenon when applying an ac. Two mechanisms-the dominant one, electric-induced deformation, and a secondary one, thermal-induced expansion of PDA-are proposed to contribute to these interesting actuation performances of the graphene-PDA actuators. On the basis of these results, a mini-robot with controllable direction of motion based on the graphene-PDA actuator is designed to illustrate the great potential of our discoveries for practical use. Combining the unique actuation mechanism and many outstanding properties of graphene and PDA, this novel kind of graphene-PDA actuator exhibits compelling advantages to traditional electromechanical actuation technology and may provide a new avenue for actuation applications.
The study and implementation of the wireless network data security model
NASA Astrophysics Data System (ADS)
Lin, Haifeng
2013-03-01
In recent years, the rapid development of Internet technology and the advent of information age, people are increasing the strong demand for the information products and the market for information technology. Particularly, the network security requirements have become more sophisticated. This paper analyzes the wireless network in the data security vulnerabilities. And a list of wireless networks in the framework is the serious defects with the related problems. It has proposed the virtual private network technology and wireless network security defense structure; and it also given the wireless networks and related network intrusion detection model for the detection strategies.
Wireless Network Communications Overview for Space Mission Operations
NASA Technical Reports Server (NTRS)
Fink, Patrick W.
2009-01-01
The mission of the On-Board Wireless Working Group (WWG) is to serve as a general CCSDS focus group for intra-vehicle wireless technologies. The WWG investigates and makes recommendations pursuant to standardization of applicable wireless network protocols, ensuring the interoperability of independently developed wireless communication assets. This document presents technical background information concerning uses and applicability of wireless networking technologies for space missions. Agency-relevant driving scenarios, for which wireless network communications will provide a significant return-on-investment benefiting the participating international agencies, are used to focus the scope of the enclosed technical information.
Murphy, Andrea L; Fleming, Mark; Martin-Misener, Ruth; Sketris, Ingrid S; MacCara, Mary; Gass, David
2006-01-01
Background Keeping current with drug therapy information is challenging for health care practitioners. Technologies are often implemented to facilitate access to current and credible drug information sources. In the Canadian province of Nova Scotia, legislation was passed in 2002 to allow nurse practitioners (NPs) to practice collaboratively with physician partners. The purpose of this study was to determine the current utilization patterns of information technologies by these groups of practitioners. Methods Nurse practitioners and their collaborating physician partners in Nova Scotia were sent a survey in February 2005 to determine the frequency of use, usefulness, accessibility, credibility, and current/timeliness of personal digital assistant (PDA), computer, and print drug information resources. Two surveys were developed (one for PDA users and one for computer users) and revised based on a literature search, stakeholder consultation, and pilot-testing results. A second distribution to nonresponders occurred two weeks following the first. Data were entered and analysed with SPSS. Results Twenty-seven (14 NPs and 13 physicians) of 36 (75%) recipients responded. 22% (6) returned personal digital assistant (PDA) surveys. Respondents reported print, health professionals, and online/electronic resources as the most to least preferred means to access drug information, respectively. 37% and 35% of respondents reported using "both print and electronic but print more than electronic" and "print only", respectively, to search monograph-related drug information queries whereas 4% reported using "PDA only". Analysis of respondent ratings for all resources in the categories print, health professionals and other, and online/electronic resources, indicated that the Compendium of Pharmaceuticals and Specialties and pharmacists ranked highly for frequency of use, usefulness, accessibility, credibility, and current/timeliness by both groups of practitioners. Respondents' preferences and resource ratings were consistent with self-reported methods for conducting drug information queries. Few differences existed between NP and physician rankings of resources. Conclusion The use of computers and PDAs remains limited, which is also consistent with preferred and frequent use of print resources. Education for these practitioners regarding available electronic drug information resources may facilitate future computer and PDA use. Further research is needed to determine methods to increase computer and PDA use and whether these technologies affect prescribing and patient outcomes. PMID:16822323
Automated Percentage of Breast Density Measurements for Full-field Digital Mammography Applications.
Fowler, Erin E E; Vachon, Celine M; Scott, Christopher G; Sellers, Thomas A; Heine, John J
2014-08-01
Increased mammographic breast density is a significant risk factor for breast cancer. A reproducible, accurate, and automated breast density measurement is required for full-field digital mammography (FFDM) to support clinical applications. We evaluated a novel automated percentage of breast density measure (PDa) and made comparisons with the standard operator-assisted measure (PD) using FFDM data. We used a nested breast cancer case-control study matched on age, year of mammogram and diagnosis with images acquired from a specific direct x-ray conversion FFDM technology. PDa was applied to the raw and clinical display (or processed) representation images. We evaluated the transformation (pixel mapping) of the raw image, giving a third representation (raw-transformed), to improve the PDa performance using differential evolution optimization. We applied PD to the raw and clinical display images as a standard for measurement comparison. Conditional logistic regression was used to estimate the odd ratios (ORs) for breast cancer with 95% confidence intervals (CI) for all measurements; analyses were adjusted for body mass index. PDa operates by evaluating signal-dependent noise (SDN), captured as local signal variation. Therefore, we characterized the SDN relationship to understand the PDa performance as a function of data representation and investigated a variation analysis of the transformation. The associations of the quartiles of operator-assisted PD with breast cancer were similar for the raw (OR: 1.00 [ref.]; 1.59 [95% CI, 0.93-2.70]; 1.70 [95% CI, 0.95-3.04]; 2.04 [95% CI, 1.13-3.67]) and clinical display (OR: 1.00 [ref.]; 1.31 [95% CI, 0.79-2.18]; 1.14 [95% CI, 0.65-1.98]; 1.95 [95% CI, 1.09-3.47]) images. PDa could not be assessed on the raw images without preprocessing. However, PDa had similar associations with breast cancer when assessed on 1) raw-transformed (OR: 1.00 [ref.]; 1.27 [95% CI, 0.74-2.19]; 1.86 [95% CI, 1.05-3.28]; 3.00 [95% CI, 1.67-5.38]) and 2) clinical display (OR: 1.00 [ref.]; 1.79 [95% CI, 1.04-3.11]; 1.61 [95% CI, 0.90-2.88]; 2.94 [95% CI, 1.66-5.19]) images. The SDN analysis showed that a nonlinear relationship between the mammographic signal and its variation (ie, the biomarker for the breast density) is required for PDa. Although variability in the transform influenced the respective PDa distribution, it did not affect the measurement's association with breast cancer. PDa assessed on either raw-transformed or clinical display images is a valid automated breast density measurement for a specific FFDM technology and compares well against PD. Further work is required for measurement generalization. Copyright © 2014 AUR. Published by Elsevier Inc. All rights reserved.
ERIC Educational Resources Information Center
Gan, Chin Lay; Balakrishnan, Vimala
2014-01-01
The aim of this paper is to identify adoption factors of mobile wireless technology to increase interactivity between lecturers and students during lectures. A theoretical framework to ascertain lecturers' intentions to use mobile wireless technology during lectures (dependent variable) is proposed with seven independent variables. The…
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-17
... Production Act of 1993--Wireless Industrial Technology Konsortium, Inc. Notice is hereby given that, on..., 15 U.S.C. 4301 et seq. (``the Act''), Wireless Industrial Technology Konsortium, Inc. (``WITECK... circumstances. Specifically, Software Technologies Group, Westchester, IL, has withdrawn as a party to this...
ERIC Educational Resources Information Center
Oriaku, Ngozi
2008-01-01
Wireless technologies have revolutionized the ways teaching and learning have become in many colleges and universities. It is therefore interesting to observe the way wireless technologies are used to organize small group meetings. It provides online access to internet resources such as instructor lecture series. It finally helps in…
Liu, Chen-Chung; Chou, Chien-Chia; Liu, Baw-Jhiune; Yang, Jui-Wen
2006-01-01
Hard of hearing students usually face more difficulties at school than other students. A classroom environment with wireless technology was implemented to explore whether wireless technology could enhance mathematics learning and teaching activities for a hearing teacher and her 7 hard of hearing students in a Taiwan junior high school. Experiments showed that the highly interactive communication through the wireless network increased student participation in learning activities. Students demonstrated more responses to the teacher and fewer distraction behaviors. Fewer mistakes were made in in-class course work because Tablet PCs provided students scaffolds. Students stated that the environment with wireless technology was desirable and said that they hoped to continue using the environment to learn mathematics.
Wireless Technology Use Case Requirement Analysis for Future Space Applications
NASA Technical Reports Server (NTRS)
Abedi, Ali; Wilkerson, DeLisa
2016-01-01
This report presents various use case scenarios for wireless technology -including radio frequency (RF), optical, and acoustic- and studies requirements and boundary conditions in each scenario. The results of this study can be used to prioritize technology evaluation and development and in the long run help in development of a roadmap for future use of wireless technology. The presented scenarios cover the following application areas: (i) Space Vehicles (manned/unmanned), (ii) Satellites and Payloads, (iii) Surface Explorations, (iv) Ground Systems, and (v) Habitats. The requirement analysis covers two parallel set of conditions. The first set includes the environmental conditions such as temperature, radiation, noise/interference, wireless channel characteristics and accessibility. The second set of requirements are dictated by the application and may include parameters such as latency, throughput (effective data rate), error tolerance, and reliability. This report provides a comprehensive overview of all requirements from both perspectives and details their effects on wireless system reliability and network design. Application area examples are based on 2015 NASA Technology roadmap with specific focus on technology areas: TA 2.4, 3.3, 5.2, 5.5, 6.4, 7.4, and 10.4 sections that might benefit from wireless technology.
Applied research of embedded WiFi technology in the motion capture system
NASA Astrophysics Data System (ADS)
Gui, Haixia
2012-04-01
Embedded wireless WiFi technology is one of the current wireless hot spots in network applications. This paper firstly introduces the definition and characteristics of WiFi. With the advantages of WiFi such as using no wiring, simple operation and stable transmission, this paper then gives a system design for the application of embedded wireless WiFi technology in the motion capture system. Also, it verifies the effectiveness of design in the WiFi-based wireless sensor hardware and software program.
ERIC Educational Resources Information Center
Liu, Chen-Chung; Chou, Chien-Chia; Liu, Baw-Jhiune; Yang, Jui-Wen
2006-01-01
Hard of hearing students usually face more difficulties at school than other students. A classroom environment with wireless technology was implemented to explore whether wireless technology could enhance mathematics learning and teaching activities for a hearing teacher and her 7 hard of hearing students in a Taiwan junior high school.…
A review and a framework of handheld computer adoption in healthcare.
Lu, Yen-Chiao; Xiao, Yan; Sears, Andrew; Jacko, Julie A
2005-06-01
Wide adoption of mobile computing technology can potentially improve information access, enhance workflow, and promote evidence-based practice to make informed and effective decisions at the point of care. Handheld computers or personal digital assistants (PDAs) offer portable and unobtrusive access to clinical data and relevant information at the point of care. This article reviews the literature on issues related to adoption of PDAs in health care and barriers to PDA adoption. Studies showed that PDAs were used widely in health care providers' practice, and the level of use is expected to rise rapidly. Most care providers found PDAs to be functional and useful in areas of documentation, medical reference, and access to patient data. Major barriers to adoption were identified as usability, security concerns, and lack of technical and organizational support. PDAs offer health care practitioners advantages to enhance their clinical practice. However, better designed PDA hardware and software applications, more institutional support, seamless integration of PDA technology with hospital information systems, and satisfactory security measures are necessary to increase acceptance and wide use of PDAs in healthcare.
Design and validation of wireless system for oil monitoring base on optical sensing unit
NASA Astrophysics Data System (ADS)
Niu, Liqun; Wang, Weiming; Zhang, Shuaishuai; Li, Zhirui; Yu, Yan; Huang, Hui
2017-04-01
According to the situation of oil leakage and the development of oil detection technology, a wireless monitoring system, combining with the sensor technology, optical measurement technology, and wireless technology, is designed. In this paper, the architecture of a wireless system is designed. In the hardware, the collected data, acquired by photoelectric conversion and analog to digital conversion equipment, will be sent to the upper machine where they are saved and analyzed. The experimental results reveals that the wireless system has the characteristics of higher precision, more real-time and more convenient installation, it can reflect the condition of the measuring object truly and implement the dynamic monitoring for a long time on-site, stability—thus it has a good application prospect in the oil monitoring filed.
Wireless technology in disease management and medicine.
Clifford, Gari D; Clifton, David
2012-01-01
Healthcare information, and to some extent patient management, is progressing toward a wireless digital future. This change is driven partly by a desire to improve the current state of medicine using new technologies, partly by supply-and-demand economics, and partly by the utility of wireless devices. Wired technology can be cumbersome for patient monitoring and can restrict the behavior of the monitored patients, introducing bias or artifacts. However, wireless technologies, while mitigating some of these issues, have introduced new problems such as data dropout and "information overload" for the clinical team. This review provides an overview of current wireless technology used for patient monitoring and disease management. We identify some of the major related issues and describe some existing and possible solutions. In particular, we discuss the rapidly evolving fields of telemedicine and mHealth in the context of increasingly resource-constrained healthcare systems.
Bluetooth Low Energy: Wireless Connectivity for Medical Monitoring
Omre, Alf Helge
2010-01-01
Electronic wireless sensors could cut medical costs by enabling physicians to remotely monitor vital signs such as blood pressure, blood glucose, and blood oxygenation while patients remain at home. According to the IDC report “Worldwide Bluetooth Semiconductor 2008-2012 Forecast,” published November 2008, a forthcoming radio frequency communication (“wireless connectivity”) standard, Bluetooth low energy, will link wireless sensors via radio signals to the 70% of cell phones and computers likely to be fitted with the next generation of Bluetooth wireless technology, leveraging a ready-built infrastructure for data transmission. Analysis of trends indicated by this data can help physicians better manage diseases such as diabetes. The technology also addresses the concerns of cost, compatibility, and interoperability that have previously stalled widespread adoption of wireless technology in medical applications. PMID:20307407
A Solution on Identification and Rearing Files Insmallhold Pig Farming
NASA Astrophysics Data System (ADS)
Xiong, Benhai; Fu, Runting; Lin, Zhaohui; Luo, Qingyao; Yang, Liang
In order to meet government supervision of pork production safety as well as consumeŕs right to know what they buy, this study adopts animal identification, mobile PDA reader, GPRS and other information technologies, and put forward a data collection method to set up rearing files of pig in smallhold pig farming, and designs related metadata structures and its mobile database, and develops a mobile PDA embedded system to collect individual information of pig and uploading into the remote central database, and finally realizes mobile links to the a specific website. The embedded PDA can identify both a special pig bar ear tag appointed by the Ministry of Agricultural and a general data matrix bar ear tag designed by this study by mobile reader, and can record all kinds of inputs data including bacterins, feed additives, animal drugs and even some forbidden medicines and submitted them to the center database through GPRS. At the same time, the remote center database can be maintained by mobile PDA and GPRS, and finally reached pork tracking from its origin to consumption and its tracing through turn-over direction. This study has suggested a feasible technology solution how to set up network pig electronic rearing files involved smallhold pig farming based on farmer and the solution is proved practical through its application in the Tianjińs pork quality traceability system construction. Although some individual techniques have some adverse effects on the system running such as GPRS transmitting speed now, these will be resolved with the development of communication technology. The full implementation of the solution around China will supply technical supports in guaranteeing the quality and safety of pork production supervision and meet consumer demand.
NASA Technical Reports Server (NTRS)
Alexandrov, Natalia; Holmes, Bruce J.; Hahn, Andrew S.
2016-01-01
We report on an examination of potential benefits of infusing wireless technologies into various areas of aircraft and airspace operations. The analysis is done in support of a NASA seedling project Efficient Reconfigurable Cockpit Design and Fleet Operations Using Software Intensive, Network Enabled Wireless Architecture (ECON). The study has two objectives. First, we investigate one of the main benefit hypotheses of the ECON proposal: that the replacement of wired technologies with wireless would lead to significant weight reductions on an aircraft, among other benefits. Second, we advance a list of wireless technology applications and discuss their system benefits. With regard to the primary hypothesis, we conclude that the promise of weight reduction is premature. Specificity of the system domain and aircraft, criticality of components, reliability of wireless technologies, the weight of replacement or augmentation equipment, and the cost of infusion must all be taken into account among other considerations, to produce a reliable estimate of weight savings or increase.
Review: Security in Wireless Technologies in Business
NASA Astrophysics Data System (ADS)
Sattarova, F. Y.; Kim, Tai-Hoon
Wireless technology seems to be everywhere now - but it is still relatively in its infancy. New standards and protocols continue to emerge and problems and bugs are discovered. Nevertheless, wireless networks make many things much more convenient and it appears that wireless networks are here to stay. The differences and similarities of wireless and wired security, the new threats brought by mobility, the security of networks and devices and effects of security, or lack of it are shortly discussed in this review paper.
Technology of short-distance wireless communication and its application based on equipment support
NASA Astrophysics Data System (ADS)
Yu, Yang; Zheng, Liping; Zhu, Jianjie; Cao, Yingxiu; Hu, Bei
2018-04-01
This paper briefly introduces some common short-region wireless communication technologies, comprehensively compares the application characteristics of each technology, and summarizes the application prospect of these technologies in equipment support.
ERIC Educational Resources Information Center
Joan, D. R. Robert
2015-01-01
The objective of the study was to find out the effect of learning through Wireless technologies and the traditional method in teaching and learning Mathematics. The investigator adopted experimental research to find the effectiveness of implementing Wireless technologies in the population of B.Ed. trainees. The investigator selected 32 B.Ed.…
Wireless as Enabler of Innovation in 21.
Ball, Eddie; Vasileiadis, Athanasios
2017-01-01
This paper overviews new and emerging wireless technologies that could positively impact on the lives of the elderly or disabled, as Social Care users of Assistive Technology (AT) for 'independent living'. Novel Internet of Things (IoT) radio systems and wireless locating systems being researched at The University of Sheffield are discussed in the context of Social Care technology use-cases.
Blaya, J A; Gomez, W; Rodriguez, P; Fraser, H
2008-08-01
One hundred and twenty-six public health centers and laboratories in Lima, Peru, without internet. We have previously shown that a personal digital assistant (PDA) based system reduces data collection delays and errors for tuberculosis (TB) laboratory results when compared to a paper system. To assess the data collection efficiency of each system and the resources required to develop, implement and transfer the PDA-based system to a resource-poor setting. Time-motion study of data collectors using the PDA-based and paper systems. Cost analysis of developing, implementing and transferring the PDA-based system to a local organization and their redeployment of the system. Work hours spent collecting and processing results decreased by 60% (P < 0.001). Users perceived this decrease to be 70% and had no technical problems they failed to fix. The total cost and time to develop and implement the intervention was US$26092 and 22 weeks. The cost to extend the system to cover nine more districts was $1125 and to implement collecting patient weights was $4107. A PDA-based system drastically reduced the effort required to collect TB laboratory results from remote locations. With the framework described, open-source software and local development, organizations in resource-poor settings could reap the benefits of this technology.
Ruiz-Garcia, Luis; Lunadei, Loredana; Barreiro, Pilar; Robla, Jose Ignacio
2009-01-01
The aim of the present paper is to review the technical and scientific state of the art of wireless sensor technologies and standards for wireless communications in the Agri-Food sector. These technologies are very promising in several fields such as environmental monitoring, precision agriculture, cold chain control or traceability. The paper focuses on WSN (Wireless Sensor Networks) and RFID (Radio Frequency Identification), presenting the different systems available, recent developments and examples of applications, including ZigBee based WSN and passive, semi-passive and active RFID. Future trends of wireless communications in agriculture and food industry are also discussed. PMID:22408551
Terahertz wireless communications based on photonics technologies.
Nagatsuma, Tadao; Horiguchi, Shogo; Minamikata, Yusuke; Yoshimizu, Yasuyuki; Hisatake, Shintaro; Kuwano, Shigeru; Yoshimoto, Naoto; Terada, Jun; Takahashi, Hiroyuki
2013-10-07
There has been an increasing interest in the application of terahertz (THz) waves to broadband wireless communications. In particular, use of frequencies above 275 GHz is one of the strong concerns among radio scientists and engineers, because these frequency bands have not yet been allocated at specific active services, and there is a possibility to employ extremely large bandwidths for ultra-broadband wireless communications. Introduction of photonics technologies for signal generation, modulation and detection is effective not only to enhance the bandwidth and/or the data rate, but also to combine fiber-optic (wired) and wireless networks. This paper reviews recent progress in THz wireless communications using telecom-based photonics technologies towards 100 Gbit/s.
Baker, Paul M A; Moon, Nathan W
2008-01-01
The near universal deployment in the United States of a wide variety of information and communications technologies, both wired and wireless, creates potential barriers to use for several key populations, including the poor, people with disabilities, and the aging. Equal access to wireless technologies and services can be achieved through a variety of mechanisms, including legislation and regulations, market-based solutions, and awareness and outreach-based approaches. This article discusses the results of policy research conducted by the Rehabilitation Engineering Research Center on Wireless Technologies (Wireless RERC) using policy Delphi polling methodology to probe stakeholders' opinions on key access barrier issues and to explore potential policy responses. Participants included disability advocates, disability/wireless technology policy makers, and product developers/manufacturers. Respondent input informed subsequent development of potential policy initiatives to increase access to these technologies. The findings from the Delphi suggest that awareness issues remain most important, especially manufacturer awareness of user needs and availability of consumer information for selecting the most appropriate wireless devices and services. Other key issues included the ability of people with disabilities to afford technologies and inadequacies in legislation and policy making for ensuring their general accessibility, as well as usefulness in emergencies. Technical issues, including interoperability, speech-to-text conversion, and hearing aid compatibility, were also identified by participating stakeholders as important. To address all these issues, Delphi respondents favored goals and options congruent with voluntary market-driven solutions where possible but also supported federal involvement, where necessary, to aid this process.
Wireless local area network for the dental office.
Mupparapu, Muralidhar
2004-01-01
Dental offices are no exception to the implementation of new and advanced technology, especially if it enhances productivity. In a rapidly transforming digital world, wireless technology has a special place, as it has truly "retired the wire" and contributed to the ease and efficient access to patient data and other software-based applications for diagnosis and treatment. If the office or the clinic is networked, access to patient management software, imaging software and treatment planning tools is enhanced. Access will be further enhanced and unrestricted if the entire network is wireless. As with any new, emerging technology, there will be issues that should be kept in mind before adapting to the wireless environment. Foremost is the network security involved in the installation and use of these wireless networks. This short, technical manuscript deals with standards and choices in wireless technology currently available for implementation within a dental office. The benefits of each network security protocol available to protect patient data and boost the efficiency of a modern dental office are discussed.
Design and implementation of a bluetooth-based band-aid pulse rate sensor
NASA Astrophysics Data System (ADS)
Kumar, Prashanth S.; Oh, Sechang; Rai, Pratyush; Kwon, Hyeokjun; Banerjee, Nilanjan; Varadan, Vijay K.
2011-04-01
Remote patient monitoring systems capable of collecting vital patient data such as blood pressure readings, Electrocardiograph (ECG) waveforms, and heart rate can obviate the need for repeated visits to the hospital. Moreover, such systems that continuously monitor the human physiology can provide valuable data to prognosticate the onset of critical health problems. The key to such remote health diagnostics is the design of minimally intrusive, low cost sensors that do not impede a patient's quotidian life but at the same time collect reliable noise free data. To this end, in this paper, we design and implement a Bluetooth-based wireless sensor system with a disposable sensor element and a reusable wireless component that can be worn as a "band-aid". The sensor is a piezoelectric polymer film placed on the wrist in proximity to the radial artery. The band-aid sized sensor allows non-intrusive monitoring of the pulsatile flow of blood in the artery. The sensor, using the Bluetooth module, can communicate with any Bluetooth enabled computer, mobile phone, or PDA. The data collected from the patient can be remotely viewed and analyzed by a physician.
Mobile phone based SCADA for industrial automation.
Ozdemir, Engin; Karacor, Mevlut
2006-01-01
SCADA is the acronym for "Supervisory Control And Data Acquisition." SCADA systems are widely used in industry for supervisory control and data acquisition of industrial processes. Conventional SCADA systems use PC, notebook, thin client, and PDA as a client. In this paper, a Java-enabled mobile phone has been used as a client in a sample SCADA application in order to display and supervise the position of a sample prototype crane. The paper presents an actual implementation of the on-line controlling of the prototype crane via mobile phone. The wireless communication between the mobile phone and the SCADA server is performed by means of a base station via general packet radio service (GPRS) and wireless application protocol (WAP). Test results have indicated that the mobile phone based SCADA integration using the GPRS or WAP transfer scheme could enhance the performance of the crane in a day without causing an increase in the response times of SCADA functions. The operator can visualize and modify the plant parameters using his mobile phone, without reaching the site. In this way maintenance costs are reduced and productivity is increased.
Wireless Sensor Networks: Monitoring and Control
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hastbacka, Mildred; Ponoum, Ratcharit; Bouza, Antonio
2013-05-31
The article discusses wireless sensor technologies for building energy monitoring and control. This article, also, addresses wireless sensor networks as well as benefits and challenges of using wireless sensors. The energy savings and market potential of wireless sensors are reviewed.
Application of wireless sensor network technology in logistics information system
NASA Astrophysics Data System (ADS)
Xu, Tao; Gong, Lina; Zhang, Wei; Li, Xuhong; Wang, Xia; Pan, Wenwen
2017-04-01
This paper introduces the basic concepts of active RFID (WSN-ARFID) based on wireless sensor networks and analyzes the shortcomings of the existing RFID-based logistics monitoring system. Integrated wireless sensor network technology and the scrambling point of RFID technology. A new real-time logistics detection system based on WSN and RFID, a model of logistics system based on WSN-ARFID is proposed, and the feasibility of this technology applied to logistics field is analyzed.
Dwolatzky, Barry; Trengove, Estelle; Struthers, Helen; McIntyre, James A; Martinson, Neil A
2006-01-01
Background Tuberculosis (TB) is the leading clinical manifestation of HIV infection and caseloads continue to increase in high HIV prevalence settings. TB treatment is prolonged and treatment interruption has serious individual and public health consequences. We assessed the feasibility of using a handheld computing device programmed with customised software and linked to a GPS receiver, to assist TB control programmes to trace patients who interrupt treatment in areas without useful street maps. In this proof of concept study, we compared the time taken to re-find a home comparing given residential addresses with a customised personalised digital assistant linked to a global positioning system (PDA/GPS) device. Additionally, we assessed the feasibility of using aerial photographs to locate homes. Results The study took place in two communities in Greater Johannesburg, South Africa: Wheillers Farm, a relatively sparsely populated informal settlement, and a portion of Alexandra, an urban township with densely populated informal settlements. Ten participants in each community were asked to locate their homes on aerial photographs. Nine from Wheillers Farm and six from Alexandra were able to identify their homes. The total time taken by a research assistant, unfamiliar with the area, to locate 10 homes in each community using the given addresses was compared with the total time taken by a community volunteer with half an hour of training to locate the same homes using the device. Time taken to locate the ten households was reduced by 20% and 50% in each community respectively using the PDA/GPS device. Conclusion In this pilot study we show that it is feasible to use a simple PDA/GPS device to locate the homes of patients. We found that in densely populated informal settlements, GPS technology is more accurate than aerial photos in identifying homes and more efficient than addresses provided by participants. Research assessing issues of, confidentiality and cost effectiveness would have to be undertaken before implementing PDA/GPS – based technology for this application. However, this PDA/GPS device could be used to reduce part of the burden on TB control programs. PMID:16911806
Repetto, Robert; Levy, Richard
2015-01-01
The application of single-use systems, or disposables, has increased dramatically in the past 10 years. Although some elements of the pharmaceutical and biotech manufacturing process were single-use and therefore disposable and not reused, the majority of the process equipment and fluid path was cleaned and reused by end users. Today, much more of the manufacturing process is composed of single-use systems, and there are some biotech plants that use single-use systems exclusively. Because of this increasing reliance on suppliers, there is an urgent need for more formal standards specifically for single-use system technology. The objective of this PDA-sponsored workshop held on May 14, 2014 was twofold: (1) to promote a harmonized approach to supporting single-use system activities within the industry and in so doing to minimize duplication of efforts, and (2) to communicate ongoing single-use system initiatives among the group. Representatives of ASME, ASTM, BPOG, BPSA, ELSIE, PDA, PQRI, and USP, as well as representatives of CBER and CDER of FDA, attended. Today, the majority of pharmaceutical and biotech drug manufacturing equipment is cleaned and reused. However, in the past 10 years, the use of disposable manufacturing systems has increased dramatically; there are even some biotech-derived drugs that are manufactured entirely using single-use technology. This movement toward disposables has placed increased reliance on disposable equipment suppliers, each of which manufactures its products independently to meet customer needs. This fact has led to non-uniformity in design for connectors and similar sub-processes, and has made the need for more formal industry standards. The objective of this PDA-sponsored workshop held on May 14, 2014 was twofold: (1) to promote a harmonized approach to supporting single-use system projects within the industry and in so doing to minimize duplication of efforts, and (2) to communicate ongoing single-use system initiatives among the group. Representatives of industry associations and standard-setting organizations, as well as representatives of the U.S. Food and Drug Administration, attended. © PDA, Inc. 2015.
Wireless infrared communications for space and terrestrial applications
NASA Technical Reports Server (NTRS)
Crimmins, James W.
1993-01-01
Voice and data communications via wireless (and fiberless) optical means has been commonplace for many years. However, continuous advances in optoelectronics and microelectronics have resulted in significant advances in wireless optical communications over the last decade. Wilton has specialized in diffuse infrared voice and data communications since 1979. In 1986, NASA Johnson Space Center invited Wilton to apply its wireless telecommunications and factory floor technology to astronaut voice communications aboard the shuttle. In September, 1988 a special infrared voice communications system flew aboard a 'Discovery' Shuttle mission as a flight experiment. Since then the technology has been further developed, resulting in a general purpose of 2Mbs wireless voice/data LAN which has been tested for a variety of applications including use aboard Spacelab. Funds for Wilton's wireless IR development were provided in part by NASA's Technology Utilization Office and by the NASA Small Business Innovative Research Program. As a consequence, Wilton's commercial product capability has been significantly enhanced to include diffuse infrared wireless LAN's as well as wireless infrared telecommunication systems for voice and data.
Mupparapu, Muralidhar
2007-06-01
Although it sounds like a nonvital tooth, Bluetooth is actually one of technology's hottest trends. It is an industrial specification for wireless personal area networks, but for a busy orthodontic practice, it translates to freedom from cables and cords. Despite its enigmatic name, Bluetooth-based devices and the wireless technology that these gadgets work with are here to stay. They promise to make life easier for the electronic-device users of all stripes, and orthodontists are no exception. The purpose of this article is to orient orthodontists, office staff, and auxiliary personnel to this universal wireless technology that is slowly becoming an integral part of every office.
A Sensible Approach to Wireless Networking.
ERIC Educational Resources Information Center
Ahmed, S. Faruq
2002-01-01
Discusses radio frequency (R.F.) wireless technology, including industry standards, range (coverage) and throughput (data rate), wireless compared to wired networks, and considerations before embarking on a large-scale wireless project. (EV)
75 FR 19340 - Wireless Technologies, Devices, and Services
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-14
... Technologies, Devices, and Services AGENCY: Federal Communications Commission. ACTION: Proposed rule. SUMMARY... technologies, devices, and services. Specifically, the Commission seeks comment regarding particular changes to... concise rules that facilitate new wireless technologies, devices and services, and are easy for the public...
Are Wireless Networks the Wave of the Future?
ERIC Educational Resources Information Center
Young, Jeffrey R.
1999-01-01
Some college administrators feel the next major trend in educational technology will be wireless networks that let students and professors connect to the Internet with radio waves rather than cumbersome cables. Several universities are already using the less expensive technology. However, some find the slower speed of available wireless services…
ERIC Educational Resources Information Center
Milner, Jacob
2005-01-01
In districts big and small across the U.S., students, teachers, and administrators alike have come to appreciate the benefits of wireless technology. Because the technology delivers Internet signals on airborne radio frequencies, wireless networking allows users of all portable devices to move freely on a school's campus and stay connected to the…
Hatfield, Amy J; Bangert, Michael P
2005-01-01
The Indiana University School of Medicine (IUSM) Office of Medical Education &Student Services directed the IUSM Educational Technology Unit to develop a Clinical Encounters Tracking system in response to the Liaison Committee on Medical Education's (LCME) updated accreditation standards. A personal digital assistant (PDA) and centralized database server solution was implemented. Third-year medical students are required to carry a PDA on which they record clinical encounter experiences during all clerkship clinical rotations. Clinical encounters data collected on the PDAs are routinely uploaded to the central server via the PDA HotSyncing process. Real-time clinical encounter summary reports are accessed in the school's online curriculum management system: ANGEL. The resulting IUSM Clinical Encounters Tracking program addresses the LCME accreditation standard which mandates the tracking of medical students' required clinical curriculum experiences.
Wireless local area network security.
Bergeron, Bryan P
2004-01-01
Wireless local area networks (WLANs) are increasingly popular in clinical settings because they facilitate the use of wireless PDAs, laptops, and other pervasive computing devices at the point of care. However, because of the relative immaturity of wireless network technology and evolving standards, WLANs, if improperly configured, can present significant security risks. Understanding the security limitations of the technology and available fixes can help minimize the risks of clinical data loss and maintain compliance with HIPAA guidelines.
NASA Astrophysics Data System (ADS)
Li, Xiaoli; Lu, Haijun; Zhang, Yun; He, Fu; Jing, Lingyun; He, Xinghua
2016-12-01
A simple and efficient method for production of magnetic composites by decorating CoFe2O4 with polydopamine (PDA) through oxidative polymerization of dopamine was conducted. Further, magnetic alginate beads with porous structure containing well-dispersed CoFe2O4-PDA were fabricated by ionic crosslinking technology. The resulting SA@CoFe2O4-PDA beads were characterized using scanning electron microscopy, Fourier transform infrared spectrometry, X-ray diffractometer, vibrating sample magnetometer and X-ray photoelectron spectroscopy. Adsorption potential of SA@CoFe2O4-PDA beads for organic dyes including Methylene Blue (MB), Crystal Violet (CV) and Malachite Green (MG) was evaluated. SA@CoFe2O4-PDA beads exhibited excellent adsorption performances due to the composite effect, large surface area and porous structure. Organic dyes could be removed from water solution with high efficiency in a wide pH range of 4.0-9.0. Moreover, it exhibited much higher adsorptivity towards MB and CV with the maximum adsorption capacities of 466.60 and 456.52 mg/g, respectively, which were much higher than that of MG (248.78 mg/g). Ca-electrolyte had obvious adverse effects on MB and CV adsorption than MG. FTIR and XPS demonstrated that carboxylate, catechol, hydroxyl and amine groups might be involved in adsorption of organic dyes. The characteristics of wide pH range, high adsorption capacity and convenient magnetic separation would make SA@CoFe2O4-PDA beads as effective adsorbent for removal of organic dyes from wastewater.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-18
... DEPARTMENT OF JUSTICE Antitrust Division Notice Pursuant to the National Cooperative Research and Production Act of 1993--Wireless Industrial Technology Konsortium Inc. Notice is hereby given that, on..., 15 U.S.C. 4301 et seq. (``the Act''), Wireless Industrial Technology Konsortium Inc. (``WITEK'') has...
Wireless Sensor Needs Defined by SBIR Topics
NASA Technical Reports Server (NTRS)
Studor, George F.
2010-01-01
This slide presentation reviews the needs for wireless sensor technology from various U.S. government agencies as exhibited by an analysis of Small Business Innovation Research (SBIR) solicitations. It would appear that a multi-agency group looking at overlapping wireless sensor needs and technology projects is desired. Included in this presentation is a review of the NASA SBIR process, and an examination of some of the SBIR projects from NASA, and other agencies that involve wireless sensor development
ERIC Educational Resources Information Center
Kim, Sang Hyun; Holmes, Kerry; Mims, Clif
2005-01-01
People commonly use technology in their daily lives. Within an increasingly complex society, individuals, organizations and other entities continue to look for new technologies that support their goals. Since the 1990s, there has been movement toward mobile wireless technology in education. Like the wired technology that came before, mobile…
Educational Affordances of PDAs: A Study of a Teacher's Exploration of This Technology
ERIC Educational Resources Information Center
Churchill, Daniel; Churchill, Natalia
2008-01-01
This paper reports on a case study of a teacher from a technical education institution who explored the educational affordances of PDA technology over a period of six months. Based on this teacher's perspectives, the study was designed to inform our own understanding of educational affordances of this new and emerging technology. Understanding of…
MEDIC: medical embedded device for individualized care.
Wu, Winston H; Bui, Alex A T; Batalin, Maxim A; Au, Lawrence K; Binney, Jonathan D; Kaiser, William J
2008-02-01
Presented work highlights the development and initial validation of a medical embedded device for individualized care (MEDIC), which is based on a novel software architecture, enabling sensor management and disease prediction capabilities, and commercially available microelectronic components, sensors and conventional personal digital assistant (PDA) (or a cell phone). In this paper, we present a general architecture for a wearable sensor system that can be customized to an individual patient's needs. This architecture is based on embedded artificial intelligence that permits autonomous operation, sensor management and inference, and may be applied to a general purpose wearable medical diagnostics. A prototype of the system has been developed based on a standard PDA and wireless sensor nodes equipped with commercially available Bluetooth radio components, permitting real-time streaming of high-bandwidth data from various physiological and contextual sensors. We also present the results of abnormal gait diagnosis using the complete system from our evaluation, and illustrate how the wearable system and its operation can be remotely configured and managed by either enterprise systems or medical personnel at centralized locations. By using commercially available hardware components and software architecture presented in this paper, the MEDIC system can be rapidly configured, providing medical researchers with broadband sensor data from remote patients and platform access to best adapt operation for diagnostic operation objectives.
The Use of SMS Support in Programming Education
ERIC Educational Resources Information Center
Kert, Serhat Bahadir
2011-01-01
The rapid developments in the communication technologies today render possible the use of new technological support tools in learning processes. Wireless, or mobile wireless, technologies are the tools whose potential contributions to education are investigated. The potential effects of these technologies on learning are explored through studies…
Capacity Limit, Link Scheduling and Power Control in Wireless Networks
ERIC Educational Resources Information Center
Zhou, Shan
2013-01-01
The rapid advancement of wireless technology has instigated the broad deployment of wireless networks. Different types of networks have been developed, including wireless sensor networks, mobile ad hoc networks, wireless local area networks, and cellular networks. These networks have different structures and applications, and require different…
Research on the key technology of update of land survey spatial data based on embedded GIS and GPS
NASA Astrophysics Data System (ADS)
Chen, Dan; Liu, Yanfang; Yu, Hai; Xia, Yin
2009-10-01
According to the actual needs of the second land-use survey and the PDA's characteristics of small volume and small memory, it can be analyzed that the key technology of the data collection system of field survey based on GPS-PDA is the read speed of the data. In order to enhance the speed and efficiency of the analysis of the spatial data on mobile devices, we classify the layers of spatial data; get the Layer-Grid Index by getting the different levels and blocks of the layer of spatial data; then get the R-TREE index of the spatial data objects. Different scale levels of space are used in different levels management. The grid method is used to do the block management.
Applying Wireless Information Technology in Field Trips--A Hong Kong Experience
ERIC Educational Resources Information Center
So, Koon Keung Teddy
2004-01-01
In 2002, the Honk Kong government launched a pilot scheme "e-school bag" promoting the use of wireless technology in ten primary and ten secondary schools for classroom teaching and learning. In 2003, a secondary school successfully received a grant from the Quality Education Fund (QEF) to implement a wireless network for outdoor field…
Initial animal studies of a wireless, batteryless, MEMS implant for cardiovascular applications.
Najafi, Nader; Ludomirsky, Achiau
2004-03-01
This paper reports the results of the initial animal studies of a wireless, batteryless, implantable pressure sensor using microelectromechanical systems (MEMS) technology. The animal studies were acute and proved the functional feasibility of using MEMS technology for wireless bio sensing. The results are very encouraging and surpassed the majority of the application's requirements, including high sampling speed and high resolution. Based on the lessons learned, second generation wireless sensors are being developed that will provide total system solution.
Design and Analysis of Secure Routing Protocol for Wireless Sensor Networks
NASA Astrophysics Data System (ADS)
Wang, Jiong; Zhang, Hua
2017-09-01
In recent years, with the development of science and technology and the progress of the times, China's wireless network technology has become increasingly prosperous and it plays an important role in social production and life. In this context, in order to further to enhance the stability of wireless network data transmission and security enhancements, the staff need to focus on routing security and carry out related work. Based on this, this paper analyzes the design of wireless sensor based on secure routing protocol.
Health technology assessment-based development of a Spanish breast cancer patient decision aid.
Izquierdo, Fátima; Gracia, Javier; Guerra, Mercedes; Blasco, Juan Antonio; Andradas, Elena
2011-10-01
The aim of this study was to develop a breast cancer Patient Decision Aid (PDA), using a Health Technology Assessment (HTA) process, to assist patients in their choice of therapeutic options, and to promote shared decision making among patients, healthcare professionals, and other interested parties. A systematic review (SR) was conducted of existing breast cancer patient Decision Aids encountered in the main scientific journal databases and on institutional Web sites that create PDAs, together with a Qualitative Research (QR) study, using semi-structured interviews and focus group with stakeholders (patients, family members, and health professionals), with the aim of developing a PDA for breast cancer. The SR shows that PDAs in breast cancer not only increase patient knowledge of the illness, leading to more realistic expectations of treatment outcomes, but also reduce passivity in the decision-making process and facilitate the appropriate choice of treatment options in accordance with patient medical and personal preferences. The analysis of QR shows that both breast cancer patients and healthcare professionals agree that surgery, adjuvant treatments, and breast reconstruction represent the most important decisions to be made. Worry, anxiety, optimism, and trust in healthcare professionals were determined as factors that most affected patients subjective experiences of the illness. This HTA was used as the basis for developing a PDA software program. The SR and QR used in the development of this PDA for breast cancer allowed patients to access information, gain additional knowledge of their illness, make shared treatment decisions, and gave healthcare professionals a deeper insight into patient experiences of the disease.
Murphy, Thomas; Schwedock, Julie; Nguyen, Kham; Mills, Anna; Jones, David
2015-01-01
New recommendations for the validation of rapid microbiological methods have been included in the revised Technical Report 33 release from the PDA. The changes include a more comprehensive review of the statistical methods to be used to analyze data obtained during validation. This case study applies those statistical methods to accuracy, precision, ruggedness, and equivalence data obtained using a rapid microbiological methods system being evaluated for water bioburden testing. Results presented demonstrate that the statistical methods described in the PDA Technical Report 33 chapter can all be successfully applied to the rapid microbiological method data sets and gave the same interpretation for equivalence to the standard method. The rapid microbiological method was in general able to pass the requirements of PDA Technical Report 33, though the study shows that there can be occasional outlying results and that caution should be used when applying statistical methods to low average colony-forming unit values. Prior to use in a quality-controlled environment, any new method or technology has to be shown to work as designed by the manufacturer for the purpose required. For new rapid microbiological methods that detect and enumerate contaminating microorganisms, additional recommendations have been provided in the revised PDA Technical Report No. 33. The changes include a more comprehensive review of the statistical methods to be used to analyze data obtained during validation. This paper applies those statistical methods to analyze accuracy, precision, ruggedness, and equivalence data obtained using a rapid microbiological method system being validated for water bioburden testing. The case study demonstrates that the statistical methods described in the PDA Technical Report No. 33 chapter can be successfully applied to rapid microbiological method data sets and give the same comparability results for similarity or difference as the standard method. © PDA, Inc. 2015.
Huang, Jing-Yi; Liu, Xiao-Lin; Zhou, Shui-Ping; Tong, Ling; Ding, Li
2014-11-01
Andrographis paniculata from different parts and origins were analyzed by UPLC-PDA fingerprint to provide refererice for related preparation technology. Using the peak of andrographolide as reference, 27 common peaks were identified, and digitized UPLC-PDA fingerprints for 23 batches of andrographis paniculata were established in this research. Principal component analysis (PCA) was carried out after feature extraction. The contents of andrographolide, neoandrographolide, deoxyandrographolide, dehydroandrographolide were determined by external standard method. The Plackett-Burman design combined with pareto chart was used to analyze the factors influencing the robustness of the method. It was found that the medicinal part has a more remarkable influence on the quality of andrographis paniculata than the origin. The contents of the 4 lactones the differ greatly in the different parts of andrographis paniculata, and the pH of the mobile phase is an important factor that influenced the robustness of the method.
The CAOS camera platform: ushering in a paradigm change in extreme dynamic range imager design
NASA Astrophysics Data System (ADS)
Riza, Nabeel A.
2017-02-01
Multi-pixel imaging devices such as CCD, CMOS and Focal Plane Array (FPA) photo-sensors dominate the imaging world. These Photo-Detector Array (PDA) devices certainly have their merits including increasingly high pixel counts and shrinking pixel sizes, nevertheless, they are also being hampered by limitations in instantaneous dynamic range, inter-pixel crosstalk, quantum full well capacity, signal-to-noise ratio, sensitivity, spectral flexibility, and in some cases, imager response time. Recently invented is the Coded Access Optical Sensor (CAOS) Camera platform that works in unison with current Photo-Detector Array (PDA) technology to counter fundamental limitations of PDA-based imagers while providing high enough imaging spatial resolution and pixel counts. Using for example the Texas Instruments (TI) Digital Micromirror Device (DMD) to engineer the CAOS camera platform, ushered in is a paradigm change in advanced imager design, particularly for extreme dynamic range applications.
Doctor of pharmacy students' use of personal digital assistants.
Siracuse, Mark V; Sowell, John G
2008-02-15
To describe the use of personal digital assistants (PDAs) by doctor of pharmacy (PharmD) students; determine the reliability of psychometric constructs that determine technology acceptance; and determine constructs that directly correlate with PDA use. A survey instrument was developed containing descriptive and psychometric items and administered to PharmD students at 2 universities. Over half of new users (58.1%) and experienced users (51.3%) reported using their PDA at least weekly. Eighty-four percent of experienced users used their PDA at least weekly to look up drug information. The most reliable scales were perceived usefulness (alpha = 0.92), perceived ease of use (alpha = 0.89), and attitude towards behavior (alpha = 0.84). Intention to use and self-reported use of PDAs were strongly correlated with perceived usefulness, attitude towards behavior, and compatibility. The majority of pharmacy students used their PDAs at least weekly and find them most useful for looking up drug information.
Carroll, A E; Saluja, S; Tarczy-Hornoch, P
2001-01-01
Personal Digital Assistants (PDAs) offer clinicians the ability to enter and manage critical information at the point of care. Although PDAs have always been designed to be intuitive and easy to use, recent advances in technology have made them even more accessible. The ability to link data on a PDA (client) to a central database (server) allows for near-unlimited potential in developing point of care applications and systems for patient data management. Although many stand-alone systems exist for PDAs, none are designed to work in an integrated client/server environment. This paper describes the design, software and hardware selection, and preliminary testing of a PDA based patient data and charting system for use in the University of Washington Neonatal Intensive Care Unit (NICU). This system will be the subject of a subsequent study to determine its impact on patient outcomes and clinician efficiency.
NASA Astrophysics Data System (ADS)
Cheng, Xiaoyan; Zhang, Xiaoli; Xie, Fangyi
To get a more convenience work in forest application, GIS and information system is used in forestry. GIS technology is used to build an informational management system of forest disease. For the practical requirement, the system is implemented by PDA which works outside to help completing the data collection. The major function of the system is input and output of the forest disease data and processing the report which is based on the criteria report and the assistant function of GIS. This article is aim to discuss about the theory, the process and the critical points of the information system. Besides the general information management system, GIS and PDA is introduced into the diseases system, which could combine the map and the attribute information and realize inventory data reform by PDA. The system is developed with VB and SuperMap Object (SuperMap Company).
Use of consumer wireless devices by South Africans with severe communication disability
Bryen, Diane Nelson; Moolman, Enid; Morris, John
2016-01-01
Background Advancements in wireless technology (e.g. cell phones and tablets) have opened new communication opportunities and environments for individuals with severe communication disabilities. The advancement of these technologies poses challenges to ensuring that these individuals enjoy equal access to this increasingly essential technology. However, a paucity of research exists. Objectives To describe the nature and frequency with which South African adults with severe communication disabilities have access to and use wireless devices, as well as the types of activities for which wireless devices are used. Method Survey research was conducted with 30 individuals who use augmentative and alternative communication (AAC) technology using the Survey of User Needs Questionnaire developed in the United States, and localized to the South African context. Results All participants, despite their limited education, unemployment and low economic status, owned and/or used mainstream wireless devices. Slightly more than half of the participants (53.3%) needed adaptations to their wireless devices. Advantages of using wireless devices were highlighted, including connecting with others (through using text messaging, social networking, making plans with others, sharing photos and videos with friends), for leisure activities (e.g. listening to music, watching videos, playing games), and for safety purposes (e.g. to navigate when lost, using the device when in trouble and needing immediate assistance). Conclusion These wireless devices offer substantial benefits and opportunities to individuals with disabilities who rely on AAC in terms of independence, social participation, education and safety/security. However, they still do not enjoy equal opportunity to access and use wireless devices relative to the non-disabled population. PMID:28730045
Use of consumer wireless devices by South Africans with severe communication disability.
Bornman, Juan; Bryen, Diane Nelson; Moolman, Enid; Morris, John
2016-01-01
Advancements in wireless technology (e.g. cell phones and tablets) have opened new communication opportunities and environments for individuals with severe communication disabilities. The advancement of these technologies poses challenges to ensuring that these individuals enjoy equal access to this increasingly essential technology. However, a paucity of research exists. To describe the nature and frequency with which South African adults with severe communication disabilities have access to and use wireless devices, as well as the types of activities for which wireless devices are used. Survey research was conducted with 30 individuals who use augmentative and alternative communication (AAC) technology using the Survey of User Needs Questionnaire developed in the United States, and localized to the South African context. All participants, despite their limited education, unemployment and low economic status, owned and/or used mainstream wireless devices. Slightly more than half of the participants (53.3%) needed adaptations to their wireless devices. Advantages of using wireless devices were highlighted, including connecting with others (through using text messaging, social networking, making plans with others, sharing photos and videos with friends), for leisure activities (e.g. listening to music, watching videos, playing games), and for safety purposes (e.g. to navigate when lost, using the device when in trouble and needing immediate assistance). These wireless devices offer substantial benefits and opportunities to individuals with disabilities who rely on AAC in terms of independence, social participation, education and safety/security. However, they still do not enjoy equal opportunity to access and use wireless devices relative to the non-disabled population.
Wireless technology applied to GIS
NASA Astrophysics Data System (ADS)
Casademont, Jordi; Lopez-Aguilera, Elena; Paradells, Josep; Rojas, Alfonso; Calveras, Anna; Barceló, Francisco; Cotrina, Josep
2004-07-01
At present, there is a growing interest in wireless applications, due to the fact that the technology begins to support them at reasonable costs. In this paper, we present the technology currently available for use in wireless environments, focusing on Geographic Information Systems. As an example, we present a newly developed platform for the commercialization of advanced geographical information services for use in portable devices. This platform uses available mobile telephone networks and wireless local area networks, but it is completely scalable to new technologies such as third generation mobile networks. Users access the service using a vector map player that runs on a Personal Digital Assistant with wireless access facilities and a Global Positioning System receiver. Before accessing the information, the player will request authorization from the server and download the requested map from it, if necessary. The platform also includes a system for improving Global Positioning System localization with the Real Time Differential Global Positioning System, which uses short GSM messages as the transmission medium.
ERIC Educational Resources Information Center
Dominick, Jay
2000-01-01
Discussion of wireless technology focuses on whether there is enough value in a wireless infrastructure for schools to justify the cost. Considers issues campuses must face, including access to the Internet, telecommunications, and networking; explains technical details; and describes wireless initiatives at Wake Forest University. (LRW)
Next-generation optical wireless communications for data centers
NASA Astrophysics Data System (ADS)
Arnon, Shlomi
2015-01-01
Data centers collect and process information with a capacity that has been increasing from year to year at an almost exponential pace. Traditional fiber/cable data center network interconnections suffer from bandwidth overload, as well as flexibility and scalability issues. Therefore, a technology-shift from the fiber and cable to wireless has already been initiated in order to meet the required data-rate, flexibility and scalability demands for next-generation data center network interconnects. In addition, the shift to wireless reduces the volume allocated to the cabling/fiber and increases the cooling efficiency. Optical wireless communication (OWC), or free space optics (FSO), is one of the most effective wireless technologies that could be used in future data centers and could provide ultra-high capacity, very high cyber security and minimum latency, due to the low index of refraction of air in comparison to fiber technologies. In this paper we review the main concepts and configurations for next generation OWC for data centers. Two families of technologies are reviewed: the first technology regards interconnects between rack units in the same rack and the second technology regards the data center network that connects the server top of rack (TOR) to the switch. A comparison between different network technologies is presented.
Design of on-board Bluetooth wireless network system based on fault-tolerant technology
NASA Astrophysics Data System (ADS)
You, Zheng; Zhang, Xiangqi; Yu, Shijie; Tian, Hexiang
2007-11-01
In this paper, the Bluetooth wireless data transmission technology is applied in on-board computer system, to realize wireless data transmission between peripherals of the micro-satellite integrating electronic system, and in view of the high demand of reliability of a micro-satellite, a design of Bluetooth wireless network based on fault-tolerant technology is introduced. The reliability of two fault-tolerant systems is estimated firstly using Markov model, then the structural design of this fault-tolerant system is introduced; several protocols are established to make the system operate correctly, some related problems are listed and analyzed, with emphasis on Fault Auto-diagnosis System, Active-standby switch design and Data-Integrity process.
Morris, Tommy J; Pajak, John; Havlik, Frank; Kenyon, Jessica; Calcagni, Dean
2006-08-01
This paper discusses the innovation process of the Battlefield Medical Information System- Tactical (BMIST), a point-of-care mobile computing solution for reducing medical errors and improving the quality of care provided to our military personnel in the field. In such remote environments, medical providers have traditionally had limited access to medical information, a situation quite analogous to that in remote areas of underdeveloped or developing countries. BMIST provides an all-in-one suite of mobile applications that empowers providers via access to critical medical information and powerful clinical decision support tools to accurately create an electronic health record (EHR). This record is synchronized with Department of Defense (DOD) joint health surveillance and medical information systems from the earliest echelons of care through chronic care provided by the Veterans Administration. Specific goals met in the initial phase were: integration of the PDA and wireless interface; development of the local application and user interface; development of a communications infrastructure and development of a data storage and retrieval system. The system had been used extensively in the field to create an EHR far forward that supports a longitudinal medical record across time and across all elements of the Military Healthcare System.
Ibrahim, Iman; Parsa, Vijay; Macpherson, Ewan; Cheesman, Margaret
2013-01-02
Wireless synchronization of the digital signal processing (DSP) features between two hearing aids in a bilateral hearing aid fitting is a fairly new technology. This technology is expected to preserve the differences in time and intensity between the two ears by co-ordinating the bilateral DSP features such as multichannel compression, noise reduction, and adaptive directionality. The purpose of this study was to evaluate the benefits of wireless communication as implemented in two commercially available hearing aids. More specifically, this study measured speech intelligibility and sound localization abilities of normal hearing and hearing impaired listeners using bilateral hearing aids with wireless synchronization of multichannel Wide Dynamic Range Compression (WDRC). Twenty subjects participated; 8 had normal hearing and 12 had bilaterally symmetrical sensorineural hearing loss. Each individual completed the Hearing in Noise Test (HINT) and a sound localization test with two types of stimuli. No specific benefit from wireless WDRC synchronization was observed for the HINT; however, hearing impaired listeners had better localization with the wireless synchronization. Binaural wireless technology in hearing aids may improve localization abilities although the possible effect appears to be small at the initial fitting. With adaptation, the hearing aids with synchronized signal processing may lead to an improvement in localization and speech intelligibility. Further research is required to demonstrate the effect of adaptation to the hearing aids with synchronized signal processing on different aspects of auditory performance.
ERIC Educational Resources Information Center
Feld, Harold
2005-01-01
With increasing frequency, communities are seeing the arrival of a new class of noncommercial broadband providers: community wireless networks (CWNs). Utilizing the same wireless technologies that many colleges and universities have used to create wireless networks on campus, CWNs are creating broadband access for free or at costs well below…
Tradeoff Analysis for Combat Service Support Wireless Communications Alternatives
DOE Office of Scientific and Technical Information (OSTI.GOV)
Burnette, John R.; Thibodeau, Christopher C.; Greitzer, Frank L.
2002-02-28
As the Army moves toward more mobile and agile forces and continued sustainment of numerous high-cost legacy logistics management systems, the requirement for wireless connectivity and a wireless network to supporting organizations has become ever more critical. There are currently several Army communications initiatives underway to resolve this wireless connectivity issue. However, to fully appreciate and understand the value of these initiatives, a Tradeoff Analysis is needed. The present study seeks to identify and assess solutions. The analysis identified issues that impede Interim Brigade Combat Team (IBCT) communication system integration and outlined core requirements for sharing of logistics data betweenmore » the field and Army battle command systems. Then, the analysis examined wireless communication alternatives as possible solutions for IBCT logistics communications problems. The current baseline system was compared with possible alternatives involving tactical radio systems, wireless/near term digital radio, cellular satellite, and third-generation (3G) wireless technologies. Cellular satellite and 3G wireless technologies offer clear advantages and should be considered for later IBCTs.« less
Meeting Report: 2015 PDA Virus & TSE Safety Forum.
Willkommen, Hannelore; Blümel, Johannes; Brorson, Kurt; Chen, Dayue; Chen, Qi; Gröner, Albrecht; Kreil, Thomas R; Ruffing, Michel; Ruiz, Sol; Scott, Dorothy; Silvester, Glenda
2016-01-01
The report provides a summary of the presentations at the Virus & TSE Safety Forum 2015 organized by the Parenteral Drug Association (PDA) and held in Cascais, Portugal, from 9 to 11 June, 2015. As with previous conferences of this series, the PDA Virus & TSE Safety Forum 2015 provided an excellent forum for the exchange of information and opinions between the industry, research organizations, and regulatory bodies. Regulatory updates on virus and TSE safety aspects illustrating current topics of discussion at regulatory agencies in Europe and the United States were provided; the conference covered emerging viruses and new virus detection systems that may be used for the investigation of human pathogenic viruses as well as the virus safety of cell substrates and of raw material of ovine/caprine or human origin. Progress of development and use of next-generation sequencing methods was shown by several examples. Virus clearance data illustrating the effectiveness of inactivation or removal methods were presented and data provided giving insight into the mechanism of action of these technologies. In the transmissible spongiform encephalopathy (TSE) part of the conference, the epidemiology of variant Creutzfeldt-Jakob disease was reviewed and an overview about diagnostic tests provided; current thinking about the spread and propagation of prions was presented and the inactivation of prions by disinfection (equipment) and in production of bovine-derived reagents (heparin) shown. The current report provides an overview about the outcomes of the 2015 PDA Virus & TSE Safety Forum, a unique event in this field. © PDA, Inc. 2016.
ERIC Educational Resources Information Center
Lee, Lisa
2007-01-01
Many universities in the UK have recently started offering their staff and students free wireless Internet access through Wireless Local Area Network (WLAN) technologies, such as Wi-Fi. Based on a small empirical study of WLAN deployment in a university setting, the article explores adoption processes of the new technology by both the organisation…
Wireless avionics for space applications of fundamental physics
NASA Astrophysics Data System (ADS)
Wang, Linna; Zeng, Guiming
2016-07-01
Fundamental physics (FP) research in space relies on a strong support of spacecraft. New types of spacecraft including reusable launch vehicles, reentry space vehicles, long-term on-orbit spacecraft or other new type of spacecraft will pave the way for FP missions. In order to test FP theories in space, flight conditions have to be controlled to a very high precision, data collection and handling abilities have to be improved, real-time and reliable communications in critical environments are needed. These challenge the existing avionics of spacecraft. Avionics consists of guidance, navigation & control, TT&C, the vehicle management, etc. Wireless avionics is one of the enabling technologies to address the challenges. Reasons are expatiated of why it is of great advantage. This paper analyses the demands for wireless avionics by reviewing the FP missions and on-board wireless systems worldwide. Main types of wireless communication are presented. Preliminary system structure of wireless avionics are given. The characteristics of wireless network protocols and wireless sensors are introduced. Key technologies and design considerations for wireless avionics in space applications are discussed.
From teaching to learning in a mobile, wireless world.
Billings, Diane M
2005-08-01
What research evidence justifies this shift from teaching to learning in the mobile, wireless world? We do not need evidence to answer questions such as, "Will the mobile, wireless device technology support teaching and learning?" (we already know it will), or "Will distance learning with mobile, wireless devices be as effective as that in the classroom?" (abundant evidence indicates there will be no significant differences). However, we do need to know, "How can we use these learning technologies to improve student learning and the outcomes of our academic programs?" Answers to this question will ultimately help educators prepare students to deliver safe and competent patient care in the mobile, wireless world.
The use of PDAs to collect baseline survey data: lessons learned from a pilot project in Bolivia.
Escandon, I N; Searing, H; Goldberg, R; Duran, R; Arce, J Monterrey
2008-01-01
We compared the use of personal digital assistants (PDAs) against the use of standard paper questionnaires for collecting survey data. The evaluation consisted of qualitative approaches to document the process of introducing PDAs. Fieldwork was carried out during June-July 2005 at 12 sites in Bolivia. Data collectors reacted positively to the use of the PDAs and noted the advantages and disadvantages of paper and PDA data collection. A number of difficulties encountered in the use of PDA technology serve as a warning for investigators planning its adoption. Problems included incompatible data files (which impeded the ability to interpret data), an inadequate back-up protocol, and lack of a good 'fit' between the technology and the study. Ensuring the existence of a back-end database, developing an appropriate and adequate back-up protocol, and assessing whether a technology 'fits' the project are important factors in weighing the decision to collect data using PDAs.
Integrated wireless systems: The future has arrived (Keynote Address)
NASA Astrophysics Data System (ADS)
Rivoir, Roberto
2005-06-01
It is believed that we are just at the beginning with wireless, and that a new age is dawning for this breakthrough technology. Thanks to several years of industrial manufacturing in mass-market applications such as cellular phones, wireless technology has nowadays reached a level of maturity that, combined with other achievements arising from different fields, such as information technology, artificial intelligence, pervasive computing, science of new materials, and micro-electro-mechanical systems (MEMS), will enable the realization of a networked stream-flow of real-time information, that will accompany us in our daily life, in a total seamless, transparent fashion. As almost any application scenario will require the deployment of complex, miniaturized, almost "invisible" systems, operating with different wireless standards, hard technological challenges will have to be faced for designing and fabricating ultra-low-cost, reconfigurable, and multi-mode heterogeneous smart micro-devices. But ongoing, unending progresses on wireless technology keeps the promise of helping to solve important societal problems in the health-care, safety, security, industry, environment sectors, and in general opening the possibility for an improved quality of life at work, on travel, at home, practically "everywhere, anytime".
Ultra-Compact Ka-Band Parabolic Deployable Antenna for RADAR and Interplanetary CubeSats
NASA Technical Reports Server (NTRS)
Sauder, Jonathan; Chahat, Nacer; Thomson, Mark; Hodges, Richard; Peral, Eva; Rahmat-Samii, Yahya
2015-01-01
Over the past several years, technology and launch opportunities for CubeSats have exploded, enabling a wide variety of missions. However, as instruments become more complex and CubeSats travel deeper into space, data communication rates become an issue. To solve this challenge, JPL has initiated a research and technology development effort to design a 0.5 meter Ka-band parabolic deployable antenna (KaPDA) which would stow in 1.5U (10 x 10 x 15 cu cm) and provide 42dB of gain (50% efficiency). A folding rib architecture and dual reflector Cassegrainian design was selected as it best balances RF gain and stowed size. The design implements an innovative telescoping waveguide and gas powered deployment. RF simulations show that after losses, the antenna would have over 42 dB gain, supported by preliminary test results. KaPDA would create opportunities for a host of new CubeSat missions by allowing high data rate communication which would enable using high fidelity instruments or venturing further into deep space, including potential interplanetary missions. Additionally KaPDA would provide a solution for other small antenna needs and the opportunity to obtain Earth science data. This paper discusses the design challenges encountered, the architecture of the solution, and the antennas expected performance capabilities.
Nollen, Nicole L.; Hutcheson, Tresza; Carlson, Susan; Rapoff, Michael; Goggin, Kathy; Mayfield, Carlene; Ellerbeck, Edward
2013-01-01
Mobile technologies hold promise for improving diet and physical activity, but little attention is given to creating programs that adolescents like and will use. This study developed a personal digital assistant (PDA) program to promote increased intake of fruits and vegetables (FV) in predominately low-income, ethnic minority girls. This study used a three-phase community-engaged process, including (i) engagement of a Student Advisory Board (SAB) to determine comfort with PDAs; (ii) early testing of Prototype I and rapid re-design by the SAB and (iii) feasibility testing of Prototype II in a new sample of girls. Phase 1 results showed that girls were comfortable with the PDA. Testing of Prototype I in Phase 2 showed that acceptability was mixed, with girls responding to 47.3% of the prompts. Girls wanted more reminders, accountability in monitoring FV, help in meeting daily goals and free music downloads based on program use. The PDA was reprogrammed and testing of Prototype II in Phase 3 demonstrated marked improvement in use (78.3%), increases in FV intake (1.8 ± 2.6 daily servings) and good overall satisfaction. Findings suggest that mobile technology designed with the early input of youth is a promising way to improve adolescent health behaviors. PMID:22949499
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-14
..., including selection of wireless technology, quality of service, coexistence, security, and electromagnetic... is an increasing concern because the electromagnetic environments where medical devices are used...
Wireless Technology in the Library: The RIT Experience: Overview of the Project.
ERIC Educational Resources Information Center
Pitkin, Pat
2001-01-01
Provides an overview of a project at RIT (Rochester Institute of Technology) that experimented with wireless technology, including laptop computers that circulate within the library building. Discusses project requirements, including ease of use, low maintenance, and low cost; motivation, including mobility; implementation; and benefits to the…
NASA Fuel Tank Wireless Power and Signal Study
NASA Technical Reports Server (NTRS)
Merrill, Garrick
2015-01-01
Hydro Technologies has developed a custom electronics and mechanical framework for interfacing with off-the-shelf sensors to achieve through barrier sensing solutions. The core project technology relies on Hydro Technologies Wireless Power and Signal Interface (Wi psi) System for transmitting data and power wirelessly using magnetic fields. To accomplish this, Wi psi uses a multi-frequency local magnetic field to produce magnetic fields capable of carrying data and power through almost any material such as metals, seawater, concrete, and air. It will also work through layers of multiple materials.
Promoting Physical Activity through Hand-Held Computer Technology
King, Abby C.; Ahn, David K.; Oliveira, Brian M.; Atienza, Audie A.; Castro, Cynthia M.; Gardner, Christopher D.
2009-01-01
Background Efforts to achieve population-wide increases in walking and similar moderate-intensity physical activities potentially can be enhanced through relevant applications of state-of-the-art interactive communication technologies. Yet few systematic efforts to evaluate the efficacy of hand-held computers and similar devices for enhancing physical activity levels have occurred. The purpose of this first-generation study was to evaluate the efficacy of a hand-held computer (i.e., personal digital assistant [PDA]) for increasing moderate intensity or more vigorous (MOD+) physical activity levels over 8 weeks in mid-life and older adults relative to a standard information control arm. Design Randomized, controlled 8-week experiment. Data were collected in 2005 and analyzed in 2006-2007. Setting/Participants Community-based study of 37 healthy, initially underactive adults aged 50 years and older who were randomized and completed the 8-week study (intervention=19, control=18). Intervention Participants received an instructional session and a PDA programmed to monitor their physical activity levels twice per day and provide daily and weekly individualized feedback, goal setting, and support. Controls received standard, age-appropriate written physical activity educational materials. Main Outcome Measure Physical activity was assessed via the Community Healthy Activities Model Program for Seniors (CHAMPS) questionnaire at baseline and 8 weeks. Results Relative to controls, intervention participants reported significantly greater 8-week mean estimated caloric expenditure levels and minutes per week in MOD+ activity (p<0.04). Satisfaction with the PDA was reasonably high in this largely PDA-naive sample. Conclusions Results from this first-generation study indicate that hand-held computers may be effective tools for increasing initial physical activity levels among underactive adults. PMID:18201644
Elliott, Lydia; DeCristofaro, Claire; Carpenter, Alesia
2012-09-01
This article describes the development and implementation of integrated use of personal handheld devices (personal digital assistants, PDAs) and high-fidelity simulation in an advanced health assessment course in a graduate family nurse practitioner (NP) program. A teaching tool was developed that can be utilized as a template for clinical case scenarios blending these separate technologies. Review of the evidence-based literature, including peer-reviewed articles and reviews. Blending the technologies of high-fidelity simulation and handheld devices (PDAs) provided a positive learning experience for graduate NP students in a teaching laboratory setting. Combining both technologies in clinical case scenarios offered a more real-world learning experience, with a focus on point-of-care service and integration of interview and physical assessment skills with existing standards of care and external clinical resources. Faculty modeling and advance training with PDA technology was crucial to success. Faculty developed a general template tool and systems-based clinical scenarios integrating PDA and high-fidelity simulation. Faculty observations, the general template tool, and one scenario example are included in this article. ©2012 The Author(s) Journal compilation ©2012 American Academy of Nurse Practitioners.
The pedagogy of Momus technologies: Facebook, privacy, and online intimacy.
van Manen, Max
2010-08-01
Through cable and wireless connections at home and at work, through Wi-Fi networks and wireless spots in hotels, coffee shops, and town squares, we are indeed connected to each other. But what is the phenomenology of this connection? Technologies of expression such as Facebook, MySpace, Twitter, and other social networking technologies increasingly become like Momus windows of Greek mythology, revealing one's innermost thoughts for all to see. They give access to what used to be personal, secret, and hidden in the lives of its users, especially the young. In this article I explore the pedagogy of Momus effects of social networking technologies in the way they may alter young people's experience of privacy, secrecy, solitude, and intimacy. In addition, I examine the forms of contact afforded by instant messaging and texting on wireless mobile technologies such as the cell phone (and its wireless hybrids) for the way young people are and stay in touch with each other, and how intimacies and inner lives are attended to.
Wireless Sensor Network With Geolocation
2006-11-01
WIRELESS SENSOR NETWORK WITH GEOLOCATION James Silverstrim and Roderick Passmore Innovative Wireless Technologies Forest, VA 24551 Dr...TYPE N/A 3. DATES COVERED - 4. TITLE AND SUBTITLE Wireless Sensor Network With Geolocation 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM...Locationing in distributed ad-hoc wireless sensor networks ”, IEEE ICASSP, May 2001. D. W. Hanson, Fundamentals of Two-Way Time Transfer by Satellite
Ibrahim, Iman; Parsa, Vijay; Macpherson, Ewan; Cheesman, Margaret
2012-01-01
Wireless synchronization of the digital signal processing (DSP) features between two hearing aids in a bilateral hearing aid fitting is a fairly new technology. This technology is expected to preserve the differences in time and intensity between the two ears by co-ordinating the bilateral DSP features such as multichannel compression, noise reduction, and adaptive directionality. The purpose of this study was to evaluate the benefits of wireless communication as implemented in two commercially available hearing aids. More specifically, this study measured speech intelligibility and sound localization abilities of normal hearing and hearing impaired listeners using bilateral hearing aids with wireless synchronization of multichannel Wide Dynamic Range Compression (WDRC). Twenty subjects participated; 8 had normal hearing and 12 had bilaterally symmetrical sensorineural hearing loss. Each individual completed the Hearing in Noise Test (HINT) and a sound localization test with two types of stimuli. No specific benefit from wireless WDRC synchronization was observed for the HINT; however, hearing impaired listeners had better localization with the wireless synchronization. Binaural wireless technology in hearing aids may improve localization abilities although the possible effect appears to be small at the initial fitting. With adaptation, the hearing aids with synchronized signal processing may lead to an improvement in localization and speech intelligibility. Further research is required to demonstrate the effect of adaptation to the hearing aids with synchronized signal processing on different aspects of auditory performance. PMID:26557339
Wireless networking for the dental office: current wireless standards and security protocols.
Mupparapu, Muralidhar; Arora, Sarika
2004-11-15
Digital radiography has gained immense popularity in dentistry today in spite of the early difficulty for the profession to embrace the technology. The transition from film to digital has been happening at a faster pace in the fields of Orthodontics, Oral Surgery, Endodontics, Periodontics, and other specialties where the radiographic images (periapical, bitewing, panoramic, cephalometric, and skull radiographs) are being acquired digitally, stored within a server locally, and eventually accessed for diagnostic purposes, along with the rest of the patient data via the patient management software (PMS). A review of the literature shows the diagnostic performance of digital radiography is at least comparable to or even better than that of conventional radiography. Similarly, other digital diagnostic tools like caries detectors, cephalometric analysis software, and digital scanners were used for many years for the diagnosis and treatment planning purposes. The introduction of wireless charged-coupled device (CCD) sensors in early 2004 (Schick Technologies, Long Island City, NY) has moved digital radiography a step further into the wireless era. As with any emerging technology, there are concerns that should be looked into before adapting to the wireless environment. Foremost is the network security involved in the installation and usage of these wireless networks. This article deals with the existing standards and choices in wireless technologies that are available for implementation within a contemporary dental office. The network security protocols that protect the patient data and boost the efficiency of modern day dental clinics are enumerated.
Rémen, T; Lacour, B
2018-05-30
In less than two decades, the wireless telecommunications sector has grown dramatically. While a large part of the world's population is now equipped with technologies from this sector (mobile phone, wireless residential telephone, Wi-Fi…), little data is available to quantify the use of these technologies. The purpose of this article is to present a description of these uses among young people, a population particularly receptive to these new telecommunication facilities. As part of the MOBI-KIDS study, a prospective epidemiological case-control study, 288 participants aged 10 to 25 years and living in France were interviewed between March 2011 and March 2015 about their history of use of wireless telecommunication devices. At the interview date, 84% of participants regularly used a mobile phone to make voice calls with an estimated cumulative duration of 45minutes per week. Of these users, 97% used the Short Message Service (SMS) sending function and 70% the data exchange functions. Regarding the use of other technologies, 88% of participants used Wi-Fi, for ten hours a week and 56% the wireless residential telephone. These uses, however, varied according to the sex and/or age of the subjects. The data draw a portrait of use, particularly quantitative, of the main wireless communication technologies in this young population. There is a gradual increase with age in the use of these technologies, while the age of initiation is at an increasingly early age. Copyright © 2018 Elsevier Masson SAS. All rights reserved.
Commercial wireless technologies for public safety users
DOT National Transportation Integrated Search
2000-07-01
This report on commercial wireless for public safety addresses the issues associated with the use of commercial services for public safety. It then reviews available wireless services for wide area data services: cellular, personal communication and ...
Wireless Sensing Opportunities for Aerospace Applications
NASA Technical Reports Server (NTRS)
Wilson, William; Atkinson, Gary
2007-01-01
Wireless sensors and sensor networks is an emerging technology area with many applications within the aerospace industry. Integrated vehicle health monitoring (IVHM) of aerospace vehicles is needed to ensure the safety of the crew and the vehicle, yet often high costs, weight, size and other constraints prevent the incorporation of instrumentation onto spacecraft. This paper presents a few of the areas such as IVHM, where new wireless sensing technology is needed on both existing vehicles as well as future spacecraft. From ground tests to inflatable structures to the International Space Station, many applications could receive benefits from small, low power, wireless sensors. This paper also highlights some of the challenges that need to overcome when implementing wireless sensor networks for aerospace vehicles.
Software-defined Radio Based Measurement Platform for Wireless Networks
Chao, I-Chun; Lee, Kang B.; Candell, Richard; Proctor, Frederick; Shen, Chien-Chung; Lin, Shinn-Yan
2015-01-01
End-to-end latency is critical to many distributed applications and services that are based on computer networks. There has been a dramatic push to adopt wireless networking technologies and protocols (such as WiFi, ZigBee, WirelessHART, Bluetooth, ISA100.11a, etc.) into time-critical applications. Examples of such applications include industrial automation, telecommunications, power utility, and financial services. While performance measurement of wired networks has been extensively studied, measuring and quantifying the performance of wireless networks face new challenges and demand different approaches and techniques. In this paper, we describe the design of a measurement platform based on the technologies of software-defined radio (SDR) and IEEE 1588 Precision Time Protocol (PTP) for evaluating the performance of wireless networks. PMID:27891210
Software-defined Radio Based Measurement Platform for Wireless Networks.
Chao, I-Chun; Lee, Kang B; Candell, Richard; Proctor, Frederick; Shen, Chien-Chung; Lin, Shinn-Yan
2015-10-01
End-to-end latency is critical to many distributed applications and services that are based on computer networks. There has been a dramatic push to adopt wireless networking technologies and protocols (such as WiFi, ZigBee, WirelessHART, Bluetooth, ISA100.11a, etc. ) into time-critical applications. Examples of such applications include industrial automation, telecommunications, power utility, and financial services. While performance measurement of wired networks has been extensively studied, measuring and quantifying the performance of wireless networks face new challenges and demand different approaches and techniques. In this paper, we describe the design of a measurement platform based on the technologies of software-defined radio (SDR) and IEEE 1588 Precision Time Protocol (PTP) for evaluating the performance of wireless networks.
Paudel, Deepak; Ahmed, Marie; Pradhan, Anjushree; Lal Dangol, Rajendra
2013-08-01
Computer-Assisted Personal Interviewing (CAPI), coupled with the use of mobile and wireless technology, is growing as a data collection methodology. Nepal, a geographically diverse and resource-scarce country, implemented the 2011 Nepal Demographic and Health Survey, a nationwide survey of major health indicators, using tablet personal computers (tablet PCs) and wireless technology for the first time in the country. This paper synthesizes responses on the benefits and challenges of using new technology in such a challenging environment from the 89 interviewers who administered the survey. Overall, feedback from the interviewers indicate that the use of tablet PCs and wireless technology to administer the survey demonstrated potential to improve data quality and reduce data collection time-benefits that outweigh manageable challenges, such as storage and transport of the tablet PCs during fieldwork, limited options for confidential interview space due to screen readability issues under direct sunlight, and inconsistent electricity supply at times. The introduction of this technology holds great promise for improving data availability and quality, even in a context with limited infrastructure and extremely difficult terrain.
Review and Evaluation of Wireless Power Transfer (WPT) for Electric Transit Applications
DOT National Transportation Integrated Search
2014-08-01
This research report provides a status review of emerging and existing Wireless Power Transfer (WPT) technologies applicable to electric bus (EB) and rail transit. The WPT technology options discussed, especially Inductive Power Transfer (IPT), enabl...
Wireless Success Story - Industrial Technologies Program (ITP)
DOE Office of Scientific and Technical Information (OSTI.GOV)
none,
This success story presents the results of wireless research by Sensors & Automation, a sub-program of the U.S. Department of Energy (DOE) Industrial Technologies Program (ITP). The prioritized research resulted in success with realized energy and cost savings.
Personal digital assistant applications for the healthcare provider.
Keplar, Kristine E; Urbanski, Christopher J
2003-02-01
To review some common medical applications available for personal digital assistants (PDAs), with brief discussion of the different PDA operating systems and memory requirements. Key search terms included handheld, PDA, personal digital assistants, and medical applications. The literature was accessed through MEDLINE (1999-August 2002). Other information was obtained through secondary sources such as Web sites describing common PDAs. Medical applications available on PDAs are numerous and include general drug references, specialized drug references (e.g., pediatrics, geriatrics, cardiology, infectious disease), diagnostic guides, medical calculators, herbal medication references, nursing references, toxicology references, and patient tracking databases. Costs and memory requirements for these programs can vary; consequently, the healthcare provider must limit the medication applications that are placed on the handheld computer. This article attempts to systematically describe the common medical applications available for the handheld computer along with cost, memory and download requirements, and Web site information. This review found many excellent PDA drug information applications offering many features which will aid the healthcare provider. Very likely, after using these PDA applications, the healthcare provider will find them indispensable, as their multifunctional capabilities can save time, improve accuracy, and allow for general business procedures as well as being a quick reference tool. To avoid the benefits of this technology might be a step backward.
Shenoy, Namdev; Nazeran, Homer
2005-01-01
In this paper we describe the application of a personal digital assistant (PDA) or pocket PC as an effective communication device to telemonitor levels of asthma triggering gases collected from a remote location under test to a workstation which has a personal computer (PC) running on Windows XP® as the operating system. The Bluetooth® features of the PDA are explored to transmit data collected by a Direct™ Sense Tox toxic gas monitor equipped with five toxic gas probes and one temperature sensor in real time, thereby making this telemonitoring system an innovative instrument in monitoring levels of asthma triggering gases in the El Paso-border metropolitan region, a region in which asthma is highly prevalent especially in children. At the workstation or fixed location these readings are displayed using a custom made, user friendly graphical user interface (GUI) developed using software tools like action scripting with Macromedia® Flash™. The growing advancement in technology and ever diminishing sizes of handheld devices encouraged us to opt for this configuration. Moreover, the PDA and toxic gas monitor were also chosen for their light weight, portability, flexibility, low cost and data collection and transmission capabilities.
Lee, Hye-Young; Jeong, Young-Il; Choi, Ki-Choon
2011-01-01
p-Phenylenediamine (PDA) or its related chemicals are used more extensively than oxidative hair dyes. However, permanent hair dyes such as PDA are known to have potent contact allergy reactions in humans, and severe allergic reactions are problematic. PDA-incorporated nanoparticles were prepared based on ion-complex formation between the cationic groups of PDA and the anionic groups of poly(γ-glutamic acid) (PGA). To reinforce PDA/PGA ion complexes, glycol chitosan (GC) was added. PDA-incorporated nanoparticles were characterized using field-emission scanning electron microscopy, Fourier- transform infrared (FT-IR) spectroscopy, dynamic light scattering, and powder X-ray diffractometry (XRD). Nanoparticles were formed by ion-complex formation between the amine groups of PDA and the carboxyl groups of PGA. PDA-incorporated nanoparticles are small in size (<100 nm), and morphological observations showed spherical shapes. FT-IR spectra results showed that the carboxylic acid peak of PGA decreased with increasing PDA content, indicating that the ion complexes were formed between the carboxyl groups of PGA and the amine groups of PDA. Furthermore, the intrinsic peak of the carboxyl groups of PGA was also decreased by the addition of GC. Intrinsic crystalline peaks of PDA were observed by XRD. This crystalline peak of PDA was completely nonexistent when nanoparticles were formed by ion complex between PDA, PGA, and GC, indicating that PDA was complexed with PGA and no free drug existed in the formulation. During the drug-release experiment, an initial burst release of PDA was observed, and then PDA was continuously released over 1 week. Cytotoxicity testing against HaCaT human skin keratinocyte cells showed PDA-incorporated nanoparticles had lower toxicity than PDA itself. Furthermore, PDA-incorporated nanoparticles showed reduced apoptosis and necrosis reaction at HaCaT cells. The authors suggest that these microparticles are ideal candidates for a vehicle for decreasing side effects of hair dye.
Wireless Internet and Student-Centered Learning: A Partial Least-Squares Model
ERIC Educational Resources Information Center
Lu, Eric Y.; Ma, Hongyan; Turner, Sandra; Huang, Wayne
2007-01-01
Wireless Internet technology is gaining a foothold on more and more campuses, yet few studies have investigated how wireless Internet supports and enhances a student-centered learning environment. This study seeks to fill the gap by developing an instrument to measure how wireless Internet supports student-centered learning. A web survey was…
A Wireless Platform for Energy Efficient Building Control Retrofits
2012-08-01
University of Illinois at Urbana Champaign UTRC United Technologies Research Center VFD variable frequency drive WSN wireless sensor network ...demonstration area. .............................................................. 16 Table 4. Cost model for wireless sensor network ...buildings with MPC-based whole-building optimal control and (2) reduction in first costs achievable with a wireless sensor network (WSN)-based
Emerging Needs for Pervasive Passive Wireless Sensor Networks on Aerospace Vehicles
NASA Technical Reports Server (NTRS)
Wilson, William C.; Juarez, Peter D.
2014-01-01
NASA is investigating passive wireless sensor technology to reduce instrumentation mass and volume in ground testing, air flight, and space exploration applications. Vehicle health monitoring systems (VHMS) are desired on all aerospace programs to ensure the safety of the crew and the vehicles. Pervasive passive wireless sensor networks facilitate VHMS on aerospace vehicles. Future wireless sensor networks on board aerospace vehicles will be heterogeneous and will require active and passive network systems. Since much has been published on active wireless sensor networks, this work will focus on the need for passive wireless sensor networks on aerospace vehicles. Several passive wireless technologies such as microelectromechanical systems MEMS, SAW, backscatter, and chipless RFID techniques, have all shown potential to meet the pervasive sensing needs for aerospace VHMS applications. A SAW VHMS application will be presented. In addition, application areas including ground testing, hypersonic aircraft and spacecraft will be explored along with some of the harsh environments found in aerospace applications.
Personal digital assistant use in Florida obstetrics and gynecology residency programs.
Joy, Saju; Benrubi, Guy
2004-05-01
Improvements in electronic technologies have resulted in affordable, smaller computers that operate at faster speeds. The personal digital assistant (PDA) is a tool that has the potential to enhance residency education by allowing residents immediate access to an abundance of information. This article assesses the current use of this tool at obstetrics and gynecology residency programs in the state of Florida. The authors conducted a statewide survey addressing the general question: is the PDA useful in an obstetrics and gynecology residency training program? Specifically, the authors asked residents how much time was perceived to be saved weekly with the use of this tool, and in what aspect of their training use of this tool was most helpful. At the survey's close, five of seven programs had returned the survey for evaluation. These five institutions included both university- and community-based residency programs. Forty percent of obstetrics and gynecology residents at these programs responded to this questionnaire. Resident responses to the survey revealed that most of the perceived benefit was in maintaining procedural statistics logs, pharmacology reference manuals, and personal clinical protocols. Most responses revealed that only minimal time savings (<2 h/wk) were gained with using this tool. However, many residents felt they were not using this tool to its maximum potential. Nearly 90% of those who responded felt that the PDA should be available at residency programs and anticipated using it after completing residency. This study posed the question of PDA usefulness at obstetric and gynecology residency programs in the state of Florida. Although not all programs provided their residents with a PDA, 95% of the respondents revealed that they owned one of these tools. Experience at the authors' institution revealed high expectations for the potential uses of a PDA. Although many residents were not using this tool to its full potential, a PDA tutorial session could educate residents on the many applications available for PDAs, including applications to maintain on-call schedules and sign-out lists, statistics and procedure logs for credentialing and board certification, electronic billing, and electronic prescriptions.
A review of the use of handheld computers in medical nutrition.
Holubar, Stefan; Harvey-Banchik, Lillian
2007-08-01
Handheld computers, or personal digital assistants (PDAs), have been used to assist clinicians in medical nutrition since the early 1980s. The term PDA was originally applied to programmable calculators; over time, the capabilities of these devices were expanded to allow for the use of more complicated programs such as databases, spreadsheets, and electronic books. Slowly, the device evolved into what is more commonly thought of as a PDA, that is, a device such as a PalmOS (PalmSource, Inc, Tokyo, Japan) or PocketPC (Microsoft, Redmond, WA) unit. We present a review of the literature about the use of PDAs in medical nutrition, followed by a discussion of the different types of PDAs and mobile technologies that are commercially available. This is followed by a discussion of software applications that are currently available for use by nutrition clinicians, focusing on freeware applications. Finally, future technologies and applications are discussed.
Wireless Technologies in Support of ISS Experimentation and Operations
NASA Technical Reports Server (NTRS)
Wagner, Raymond; Fink, Patrick
2012-01-01
Presentation reviews: (1) Wireless Communications (a) Internal (b) External (2) RFID (Radio Frequency Identification) (a) Existing and R&D (3) Wireless Sensor Networks (a) Existing and R&D (4) Ultra-Wide Band (UWB) (a) R&D
DOE Office of Scientific and Technical Information (OSTI.GOV)
Taft, Cyrus W.; Manges, Wayne W; Sorge, John N
2012-01-01
The role of wireless sensing technologies in industrial instrumentation will undoubtedly become more important in the years ahead. . Deployment of such instrumentation in an industrial setting with its heightened security and robustness criteria hinges on user acceptance of verified performance as well as meeting cost requirements. Today, industrial users face many choices when specifying a wireless sensor network, including radio performance, battery life, interoperability, security, and standards compliance. The potential market for industrial wireless sensors is literally millions of wireless instruments and it is imperative that accurate information for applying the technology to real-world applications be available to themore » end-user so that they can make informed deployment decisions. The majority of industrial wireless automation designs now being deployed or being considered for deployment are based on three different standards . The HART Communications Foundation s WirelessHART (IEC 62591), the International Society of Automation s ISA100.11a, and the offering from the Industrial Wireless Alliance of China known as WIA-PA (IEC 62601). Aside from these industrial automation standards, users must also be cognizant of the underlying wireless network standards IEEE 802.11, IEEE 802.15.4, and IEEE 802.15.3a and their interactions with the three principal industrial automation protocols mentioned previously. The crucial questions being asked by end users revolve around sensor network performance, interoperability, reliability, and security. This paper will discuss potential wireless sensor applications in power plants, barriers to the acceptance of wireless technology, concerns related to standards, and provide an end user prospective on the issues affecting wide-spread deployment of wireless sensors. Finally, the authors conclude with a discussion of a recommended path forward including how standards organizations can better facilitate end user decision making and how end users can locate and use objective information for decision making.« less
Emerging Trends in Healthcare Adoption of Wireless Body Area Networks.
Rangarajan, Anuradha
2016-01-01
Real-time personal health monitoring is gaining new ground with advances in wireless communications. Wireless body area networks (WBANs) provide a means for low-powered sensors, affixed either on the human body or in vivo, to communicate with each other and with external telecommunication networks. The healthcare benefits of WBANs include continuous monitoring of patient vitals, measuring postacute rehabilitation time, and improving quality of medical care provided in medical emergencies. This study sought to examine emerging trends in WBAN adoption in healthcare. To that end, a systematic literature survey was undertaken against the PubMed database. The search criteria focused on peer-reviewed articles that contained the keywords "wireless body area network" and "healthcare" or "wireless body area network" and "health care." A comprehensive review of these articles was performed to identify adoption dimensions, including underlying technology framework, healthcare subdomain, and applicable lessons-learned. This article benefits healthcare technology professionals by identifying gaps in implementation of current technology and highlighting opportunities for improving products and services.
Burke, Lora E.; Styn, Mindi A.; Glanz, Karen; Ewing, Linda J.; Elci, Okan U.; Conroy, Margaret B.; Sereika, Susan M.; Acharya, Sushama D.; Music, Edvin; Keating, Alison L.; Sevick, Mary Ann
2009-01-01
Background The primary form of treatment for obesity today is behavioral therapy. Self-monitoring diet and physical activity plays an important role in interventions targeting behavior and weight change. The SMART weight loss trial examined the impact of replacing the standard paper record used for self-monitoring with a personal digital assistant (PDA). This paper describes the design, methods, intervention, and baseline sample characteristics of the SMART trial. Methods The SMART trial used a 3-group design to determine the effects of different modes of self-monitoring on short- and long-term weight loss and on adherence to self-monitoring in a 24-month intervention. Participants were randomized to one of three conditions (1) use of a standard paper record (PR); (2) use of a PDA with dietary and physical activity software (PDA); or (3), use of a PDA with the same software plus a customized feedback program (PDA + FB). Results We screened 704 individuals and randomized 210. There were statistically but not clinically significant differences among the three cohorts in age, education, HDL cholesterol, blood glucose and systolic blood pressure. At 24 months, retention rate for the first of three cohorts was 90%. Conclusions To the best of our knowledge, the SMART trial is the first large study to compare different methods of self-monitoring in a behavioral weight loss intervention and to compare the use of PDAs to conventional paper records. This study has the potential to reveal significant details about self-monitoring patterns and whether technology can improve adherence to this vital intervention component. PMID:19665588
Wireless Power Control for Tactical MANET: Power Rate Bounds
2016-09-01
signals and by their inherent interference.” Figure 1. Transmission and interference in a two-link wireless network. Wireless power control seeks to...e.g., shutting off transmissions to measure the interference is impractical.) In a wireless power control system, the receiver sets its transmitter’s...Travassos Ro- mano [2013] Transmission Power Control for Opportunistic QoS Provision in Wireless Networks, IEEE Transactions on Control Systems Technology
DOT National Transportation Integrated Search
2000-08-01
This guidebook is divided into four parts: Part 1. Planning and Managing a Communications Project: Discusses the overall scope of a project, including planning, funding, procurement, and management. Part 2. Wireless Communications Technology: Discuss...
[A wireless mobile monitoring system based on bluetooth technology].
Sun, Shou-jun; Wu, Kai; Wu, Xiao-Ming
2006-09-01
This paper presents a wireless mobile monitoring system based on Bluetooth technology. This system realizes the remote mobile monitoring of multiple physiological parameters, and has the characters of easy use, low cost, good reliability and strong capability of anti-jamming.
21 CFR 874.3305 - Wireless air-conduction hearing aid.
Code of Federal Regulations, 2013 CFR
2013-04-01
...-amplifying device, intended to compensate for impaired hearing that incorporates wireless technology in its...: (1) Appropriate analysis/testing should validate electro magnetic compatibility (EMC) and safety of... technology functions; and (3) Labeling should specify appropriate instructions, warnings, and information...
[Wireless human body communication technology].
Sun, Lei; Zhang, Xiaojuan
2014-12-01
The Wireless Body Area Network (WBAN) is a key part of the wearable monitoring technologies, which has many communication technologies to choose from, like Bluetooth, ZigBee, Ultra Wideband, and Wireless Human Body Communication (WHBC). As for the WHBC developed in recent years, it is worthy to be further studied. The WHBC has a strong momentum of growth and a natural advantage in the formation of WBAN. In this paper, we first briefly describe the technical background of WHBC, then introduce theoretical model of human-channel communication and digital transmission machine based on human channel. And finally we analyze various of the interference of the WHBC and show the AFH (Adaptive Frequency Hopping) technology which can effectively deal with the interference.
ERIC Educational Resources Information Center
Fry, Joan Marian; Hin, Michael Koh Teik
2006-01-01
In technology-savvy Singapore, wireless communication devices were used over four weekly lessons to facilitate communication between pairs of student teachers (STs). In the naturalistic setting of a neighbourhood primary school, one ST used the technology to coach the other who was engaged in teaching. (Both were familiar with the lesson plan and…
Increasing Reliability with Wireless Instrumentation Systems from Space Shuttle to 'Fly-By-Wireless'
NASA Technical Reports Server (NTRS)
Studor, George
2004-01-01
This slide presentation discusses some of the requirements to allow for "Fly by Wireless". Included in the discussion are: a review of new technologies by decades starting with the 1930's and going through the current decade, structural health monitoring, the requisite system designs, and the vision of flying by wireless.
Clinical potential of implantable wireless sensors for orthopedic treatments.
Karipott, Salil Sidharthan; Nelson, Bradley D; Guldberg, Robert E; Ong, Keat Ghee
2018-04-01
Implantable wireless sensors have been used for real-time monitoring of chemicals and physical conditions of bones, tendons and muscles to diagnose and study orthopedic diseases and injuries. Due to the importance of these sensors in orthopedic care, a critical review, which not only analyzes the underlying technologies but also their clinical implementations and challenges, will provide a landscape view on their current state and their future clinical role. Areas covered: By conducting an extensive literature search and following the leaders of orthopedic implantable wireless sensors, this review covers the battery-powered and battery-free wireless implantable sensor technologies, and describes their implementation for hips, knees, spine, and shoulder stress/strain monitoring. Their advantages, limitations, and clinical challenges are also described. Expert commentary: Currently, implantable wireless sensors are mostly limited for scientific investigations and demonstrative experiments. Although rapid advancement in sensors and wireless technologies will push the reliability and practicality of these sensors for clinical realization, regulatory constraints and financial viability in medical device industry may curtail their continuous adoption for clinical orthopedic applications. In the next five years, these sensors are expected to gain increased interest from researchers, but wide clinical adoption is still unlikely.
DS-MAC: differential service medium access control design for wireless medical information systems.
Yuan, Xiaojing; Bagga, Sumegha; Shen, Jian; Balakrishnan, M; Benhaddou, D
2008-01-01
The integration of wireless networking technologies with medical information systems (telemedicine) have a significant impact on healthcare services provided to our society. Applications of telemedicine range from personalized medicine to affordable healthcare for underserved population. Though wireless technologies and medical informatics are individually progressing rapidly, wireless networking for healthcare systems is still at a very premature stage. In this paper we first present our open architecture for medical information systems that integrates both wired and wireless networked data acquisition systems. We then present the implementation at the physical layer and differential service MAC design that adapts channel provisioning based on the information criticality. Performance evaluation using analytical modeling and simulation shows that our DS-MAC provides differentiated services for emergency, warning, and normal traffic.
77 FR 71089 - Pilot Loading of Aeronautical Database Updates
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-29
... the use of newer systems and data-transfer mechanisms such as those employing wireless technology. In... which enables wireless updating of systems and databases. The current regulation does not accommodate... maintenance); Recordkeeping requirements; Training for pilots; Technological advancements in data-transfer...
ERIC Educational Resources Information Center
Tech Directions, 2011
2011-01-01
One of the hottest areas in technology is invisible. Wireless communications allow people to transmit voice messages, data, and other signals through the air without physically connecting senders to receivers with cables or wires. And the technology is spreading at lightning speed. Cellular phones, personal digital assistants, and wireless…
Our Plan for a Wireless Loan Service.
ERIC Educational Resources Information Center
Allmang, Nancy
2003-01-01
Discusses the planning for wireless technology at the research library of the National Institute of Standards and Technology (NIST). Highlights include computer equipment, including laptops and PDAs; local area networks; equipment loan service; writing a business plan; infrastructure; training programs; and future considerations, including…
Probe sampling strategies for traffic monitoring systems based on wireless location technology.
DOT National Transportation Integrated Search
2007-01-01
Transportation agencies have become very interested in traffic monitoring systems based on wireless location technology (WLT) since they offer the potential of collecting travel time data across a wide portion of the road system. Prior tests of WLT-b...
Routing and Scheduling Algorithms for WirelessHART Networks: A Survey
Nobre, Marcelo; Silva, Ivanovitch; Guedes, Luiz Affonso
2015-01-01
Wireless communication is a trend nowadays for the industrial environment. A number of different technologies have emerged as solutions satisfying strict industrial requirements (e.g., WirelessHART, ISA100.11a, WIA-PA). As the industrial environment presents a vast range of applications, adopting an adequate solution for each case is vital to obtain good performance of the system. In this context, the routing and scheduling schemes associated with these technologies have a direct impact on important features, like latency and energy consumption. This situation has led to the development of a vast number of routing and scheduling schemes. In the present paper, we focus on the WirelessHART technology, emphasizing its most important routing and scheduling aspects in order to guide both end users and the developers of new algorithms. Furthermore, we provide a detailed literature review of the newest routing and scheduling techniques for WirelessHART, discussing each of their features. These routing algorithms have been evaluated in terms of their objectives, metrics, the usage of the WirelessHART structures and validation method. In addition, the scheduling algorithms were also evaluated by metrics, validation, objectives and, in addition, by multiple superframe support, as well as by the redundancy method used. Moreover, this paper briefly presents some insights into the main WirelessHART simulation modules available, in order to provide viable test platforms for the routing and scheduling algorithms. Finally, some open issues in WirelessHART routing and scheduling algorithms are discussed. PMID:25919371
Wireless data collection system for travel time estimation and traffic performance evaluation.
DOT National Transportation Integrated Search
2012-05-01
This report presents the results of the third and final research and development project of an implementable wireless : travel time data collection system. Utilizing Bluetooth wireless technology as a platform, the prior projects focused on : data co...
NASA Astrophysics Data System (ADS)
Nopwinyuwong, Atchareeya; Kitaoka, Takuya; Boonsupthip, Waraporn; Pechyen, Chiravoot; Suppakul, Panuwat
2014-09-01
Polydiacetylene (PDA)/silica nanocomposites were synthesized by self-assembly method using polymerizable amphiphilic diacetylene monomers, 10,12-pentacosadiynoic acid (PCDA). Addition of cationic surfactants (PDADMAC and CTAB) to PDA/SiO2 nanocomposites induced higher intermolecular force which affected their size, shape and color transition. Pure PDA, PDA/SiO2, PDA/SiO2/PDADMAC and PDA/SiO2/CTAB were investigated by particle size analysis, TEM, SEM, UV-vis spectroscopy and FT-IR. It was found that the PDA/SiO2 nanocomposites exhibited slightly larger particle sizes than those of other samples. The PDA/SiO2 nanocomposites with a core-shell structure were almost regarded as spherical-shaped particles. Cationic surfactants, especially CTAB, presumably affected the particle size and shape of PDA/SiO2 nanocomposites due to the disruption of hydrogen bonding between PDA head group and ammonium group. The colorimetric response of both PDA/SiO2/surfactant and surfactant-free PDA/SiO2 aqueous solutions directly changed in relation to time and temperature; thus they were expected to be applied as a new polymer-based time-temperature indicator (TTI).
78 FR 20628 - Wireless Metering Challenge
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-05
... metering devices for use at the electrical panel level within commercial buildings. The specifications are intended to spur the development of new technologies in the wireless electric metering space. DATES... Technologies Office, Mailstop EE-2J, Office of Energy Efficiency and Renewable Energy, U.S. Department of...
Wireless Infrared Networking in the Duke Paperless Classroom.
ERIC Educational Resources Information Center
Stetten, George D.; Guthrie, Scott D.
1995-01-01
Discusses wireless (diffuse infrared) networking technology to link laptop computers in a computer programming and numerical methods course at Duke University (North Carolina). Describes products and technologies, and effects on classroom dynamics. Reports on effective instructional strategies for lecture, solving student problems, building shared…
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-10
... this important step forward. Submitted by the National Science Foundation for the National Coordination... NATIONAL SCIENCE FOUNDATION Toward Innovative Spectrum-Sharing Technologies: Wireless Spectrum.... Suzanne H. Plimpton, Reports Clearance Officer, National Science Foundation. [FR Doc. 2012-16804 Filed 7-9...
Optical wireless communication in data centers
NASA Astrophysics Data System (ADS)
Arnon, Shlomi
2018-01-01
In the last decade data centers have become a crucial element in modern human society. However, to keep pace with internet data rate growth, new technologies supporting data center should develop. Integration of optical wireless communication (OWC) in data centers is one of the proposed technologies as augmented technology to the fiber network. One implementation of the OWC technology is deployment of optical wireless transceiver on top of the existing cable/fiber network as extension to the top of rack (TOR) switch; in this way, a dynamic and flexible network is created. Optical wireless communication could reduce energy consumption, increase the data rate, reduce the communication latency, increase flexibility and scalability, and reduce maintenance time and cost, in comparison to extra fiber network deployment. In this paper we review up to date literature in the field, propose an implementation scheme of OWC network, discuss ways to reduce energy consumption by parallel link communication and report preliminary measurement result of university data center environment.
Bringing Control System User Interfaces to the Web
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Xihui; Kasemir, Kay
With the evolution of web based technologies, especially HTML5 [1], it becomes possible to create web-based control system user interfaces (UI) that are cross-browser and cross-device compatible. This article describes two technologies that facilitate this goal. The first one is the WebOPI [2], which can seamlessly display CSS BOY [3] Operator Interfaces (OPI) in web browsers without modification to the original OPI file. The WebOPI leverages the powerful graphical editing capabilities of BOY and provides the convenience of re-using existing OPI files. On the other hand, it uses generic JavaScript and a generic communication mechanism between the web browser andmore » web server. It is not optimized for a control system, which results in unnecessary network traffic and resource usage. Our second technology is the WebSocket-based Process Data Access (WebPDA) [4]. It is a protocol that provides efficient control system data communication using WebSocket [5], so that users can create web-based control system UIs using standard web page technologies such as HTML, CSS and JavaScript. WebPDA is control system independent, potentially supporting any type of control system.« less
NASA Astrophysics Data System (ADS)
Yamamoto, Toshiaki; Ueda, Tetsuro; Obana, Sadao
As one of the dynamic spectrum access technologies, “cognitive radio technology,” which aims to improve the spectrum efficiency, has been studied. In cognitive radio networks, each node recognizes radio conditions, and according to them, optimizes its wireless communication routes. Cognitive radio systems integrate the heterogeneous wireless systems not only by switching over them but also aggregating and utilizing them simultaneously. The adaptive control of switchover use and concurrent use of various wireless systems will offer a stable and flexible wireless communication. In this paper, we propose the adaptive traffic route control scheme that provides high quality of service (QoS) for cognitive radio technology, and examine the performance of the proposed scheme through the field trials and computer simulations. The results of field trials show that the adaptive route control according to the radio conditions improves the user IP throughput by more than 20% and reduce the one-way delay to less than 1/6 with the concurrent use of IEEE802.16 and IEEE802.11 wireless media. Moreover, the simulation results assuming hundreds of mobile terminals reveal that the number of users receiving the required QoS of voice over IP (VoIP) service and the total network throughput of FTP users increase by more than twice at the same time with the proposed algorithm. The proposed adaptive traffic route control scheme can enhance the performances of the cognitive radio technologies by providing the appropriate communication routes for various applications to satisfy their required QoS.
Potential uses of a wireless network in physical security systems.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Witzke, Edward L.
2010-07-01
Many possible applications requiring or benefiting from a wireless network are available for bolstering physical security and awareness at high security installations or facilities. These enhancements are not always straightforward and may require careful analysis, selection, tuning, and implementation of wireless technologies. In this paper, an introduction to wireless networks and the task of enhancing physical security is first given. Next, numerous applications of a wireless network are brought forth. The technical issues that arise when using a wireless network to support these applications are then discussed. Finally, a summary is presented.
NASA Astrophysics Data System (ADS)
1991-01-01
A technology utilization project led to the commercial adaptation of a Space Shuttle Orbiter wireless infrared voice communications system. The technology was adapted to a LAN system by Wilton Industries, one of the participants. Because the system is cable-free, installation charges are saved, and it can be used where cable is impractical. Resultant products include the IRplex 6000. Transceivers can be located anywhere and can include mobile receivers. The system provides wireless LAN coverage up to 44,000 square feet. applications include stock exchange communications, trade shows, emergency communications, etc.
Wireless Sensor Network Radio Power Management and Simulation Models
2010-01-01
The Open Electrical & Electronic Engineering Journal, 2010, 4, 21-31 21 1874-1290/10 2010 Bentham Open Open Access Wireless Sensor Network Radio...Air Force Institute of Technology, Wright-Patterson AFB, OH, USA Abstract: Wireless sensor networks (WSNs) create a new frontier in collecting and...consumption. Keywords: Wireless sensor network , power management, energy-efficiency, medium access control (MAC), simulation pa- rameters. 1
Sinkhole Avoidance Routing in Wireless Sensor Networks
2011-05-09
sensor network consists of individual sensor nodes that work cooperatively to collect and communicate environmental data. In a surveillance role, a WSN...Wireless sensor networks, or WSNs, are an emerging commercial technology that may have practical applications on the modern battlefield. A wireless
Dreher, H Michael; Cornelius, Fran; Draper, Judy; Pitkar, Harshad; Manco, Janet; Song, Il-Yeol
2006-01-01
Phase I of our Gerontological Reasoning Informatics Project (GRIP) began in the summer of 2002 when all 37 senior undergraduate nursing students in our accelerated BSN nursing program were given PDAs. These students were oriented to use a digitalized geriatric nursing assessment tool embedded into their PDA in a variety of geriatric clinical agencies. This informatics project was developed to make geriatric nursing more technology oriented and focused on seven modules of geriatric assessment: intellect (I), nutrition (N), self-concept (S), physical activity (P), interpersonal functioning (I), restful sleep (R), and elimination (E)--INSPIRE. Through phase II and now phase III, the GRIP Project has become a major collaboration between the College of Nursing & Health Professions and College of Information Science and Technology at Drexel University. The digitalized geriatric nursing health assessment tool has undergone a second round of reliability and validity testing and is now used to conduct a 20 minute comprehensive geriatric health assessment on the PDA, making our undergraduate gerontology course the most high tech clinical course in our nursing curriculum.
78 FR 8353 - Rural Broadband Access Loans and Loan Guarantees
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-06
.... Other associated rural issues, such as environmental challenges or providing wireless service through... proposed regulations, the Food, Conservation, and Energy Act of 2008, more commonly known as the 2008 Farm... wireline and wireless technologies is in violation of the agency's ``technology neutral'' mandate and...
Coexistence issues for a 2.4 GHz wireless audio streaming in presence of bluetooth paging and WLAN
NASA Astrophysics Data System (ADS)
Pfeiffer, F.; Rashwan, M.; Biebl, E.; Napholz, B.
2015-11-01
Nowadays, customers expect to integrate their mobile electronic devices (smartphones and laptops) in a vehicle to form a wireless network. Typically, IEEE 802.11 is used to provide a high-speed wireless local area network (WLAN) and Bluetooth is used for cable replacement applications in a wireless personal area network (PAN). In addition, Daimler uses KLEER as third wireless technology in the unlicensed (UL) 2.4 GHz-ISM-band to transmit full CD-quality digital audio. As Bluetooth, IEEE 802.11 and KLEER are operating in the same frequency band, it has to be ensured that all three technologies can be used simultaneously without interference. In this paper, we focus on the impact of Bluetooth and IEEE 802.11 as interferer in presence of a KLEER audio transmission.
Potential and challenges of body area networks for personal health.
Penders, Julien; van de Molengraft, Jef; Brown, Lindsay; Grundlehner, Bernard; Gyselinckx, Bert; Van Hoof, Chris
2009-01-01
This paper illustrates how body area network technology may enable new personal health concepts. A BAN technology platform is presented, which integrates technology building blocks from the Human++ research program on autonomous wireless sensors. Technology evaluation for the case of wireless sleep staging and real-time arousal monitoring is reported. Key technology challenges are discussed. The ultimate target is the development of miniaturized body sensor nodes powered by body-energy, anticipating the needs of emerging personal health applications.
Capsule endoscopy—A mechatronics perspective
NASA Astrophysics Data System (ADS)
Lin, Lin; Rasouli, Mahdi; Kencana, Andy Prima; Tan, Su Lim; Wong, Kai Juan; Ho, Khek Yu; Phee, Soo Jay
2011-03-01
The recent advances in integrated circuit technology, wireless communication, and sensor technology have opened the door for development of miniature medical devices that can be used for enhanced monitoring and treatment of medical conditions. Wireless capsule endoscopy is one of such medical devices that has gained significant attention during the past few years. It is envisaged that future wireless capsule endoscopies replace traditional endoscopy procedures by providing advanced functionalities such as active locomotion, body fluid/tissue sampling, and drug delivery. Development of energy-efficient miniaturized actuation mechanisms is a key step toward achieving this goal. Here, we review some of the actuators that could be integrated into future wireless capsules and discuss the existing challenges.
Connecting AAC devices to the world of information technology.
Caves, Kevin; Shane, Howard C; DeRuyter, Frank
2002-01-01
Modern day information technology (IT) is converging around wireless networks. It is now possible to check E-mail and view information from the World Wide Web from commercially available mobile phones. For individuals with disabilities, the ability to access multiple and different types of information not only promises convenience, but also can help to promote independence and facilitate access to public and private information systems. There are many barriers to access for people with disabilities, including technological hurdles, security, privacy, and access to these emerging wireless technologies. However, legislation, advocacy, standards, and research and development can ensure that users of augmentative and alternative communication (AAC) and assistive technology have access to these technologies. This article provides a historical context for the field of AAC and IT development, a review of the current state of these technologies, a glimpse of the potential of wireless information access for the lives of AAC users, and a description of some of the barriers and enablers to making access available to users of AAC and assistive technologies.
Terahertz (THz) Wireless Systems for Space Applications
NASA Technical Reports Server (NTRS)
Hwu, Shian U.; deSilva, Kanishka B.; Jih, Cindy T.
2013-01-01
NASA has been leading the Terahertz (THz) technology development for the sensors and instruments in astronomy in the past 20 years. THz technologies are expanding into much broader applications in recent years. Due to the vast available multiple gigahertz (GHz) broad bandwidths, THz radios offer the possibility for wireless transmission of high data rates. Multi-Gigabits per second (MGbps) broadband wireless access based on THz waves are closer to reality. The THz signal high atmosphere attenuation could significantly decrease the communication ranges and transmittable data rates for the ground systems. Contrary to the THz applications on the ground, the space applications in the atmosphere free environment do not suffer the atmosphere attenuation. The manufacturing technologies for the THz electronic components are advancing and maturing. There is great potential for the NASA future high data wireless applications in environments with difficult cabling and size/weight constraints. In this study, the THz wireless systems for potential space applications were investigated. The applicability of THz systems for space applications was analyzed. The link analysis indicates that MGbps data rates are achievable with compact sized high gain antennas.
Wireless power transfer inspired by the modern trends in electromagnetics
NASA Astrophysics Data System (ADS)
Song, Mingzhao; Belov, Pavel; Kapitanova, Polina
2017-06-01
Since the beginning of the 20th century, researchers have been looking for an effective way to transfer power without wired connections, but the wireless power transfer technology started to attract extensive interest from the industry side only in 2007 when the first smartphone was released and a consumer electronics revolution was triggered. Currently, the modern technology of wireless power transfer already has a rich research and development history as well as outstanding advances in commercialization. This review is focused on the description of distinctive implementations of this technology inspired by the modern trends in electrodynamics. We compare the performances of the power transfer systems based on three kinds of resonators, i.e., metallic coil resonators, dielectric resonators, and cavity mode resonators. We argue that metamaterials and meta-atoms are powerful tools to improve the functionalities and to obtain novel properties of the systems. We review different approaches to enhance the functionality of the wireless power transfer systems including control of the power transfer path and increase of the operation range and efficiency. Various applications of wireless power transfer are discussed and currently available standards are reviewed.
CxP Wireless DFI Summary Presentation for OTI Flight Test Working Group
NASA Technical Reports Server (NTRS)
Arteaga, Ricardo A.
2009-01-01
This slide presentation reviews the wireless instrumentation architecture needed for the Alatir Lunar Lander, Ares I, Ares V, and the Block II Orion Crew Exploration Vehicle (CEV). It includes information about the Wireless DFI system, mission planning, and the technology roadmap.
77 FR 41919 - Hearing Aid Compatibility Technical Standard
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-17
.... SUMMARY: The Wireless Telecommunications Bureau and the Office of Engineering and Technology (Bureaus) adopt the 2011 ANSI Standard for evaluating the hearing aid compatibility of wireless phones. The Bureaus take this action to ensure that a selection of digital wireless handset models is available to...
Bluetooth-enabled teleradiology: applications and complications.
Hura, Angela M
2002-01-01
Wireless personal area networks and local area networks are becoming increasingly more prevalent in the teleradiology and telemedicine industry. Although there has been much debate about the role that Bluetooth will play in the future of wireless technology, both promoters and doubters acknowledge that Bluetooth will have an impact on networking, even if only as a "niche" product. This article provides an overview of the Bluetooth standard and highlights current and future areas of inclusion for use in a teleradiology environment. The possibilities for Bluetooth in a teleradiology environment without wires are nearly boundless and an overview of current and proposed Bluetooth-enabled radiology equipment and vendors is provided. A comparison of Bluetooth and other wireless technologies is provided, including areas of similarity and potential conflict. Bluetooth and other wireless technologies can not only peacefully coexist but also complement each other and provide enhanced teleradiology services.
vMon-mobile provides wireless connection to the electronic patient record
NASA Astrophysics Data System (ADS)
Oliveira, Pedro P., Jr.; Rebelo, Marina; Pilon, Paulo E.; Gutierrez, Marco A.; Tachinardi, Umberto
2002-05-01
This work presents the development of a set of tools to help doctors to continuously monitor critical patients. Real-time monitoring signals are displayed via a Web Based Electronic Patient Record (Web-EPR) developed at the Heart Institute. Any computer on the Hospital's Intranet can access the Web-EPR that will open a browser plug-in called vMon. Recently vMon was adapted to wireless mobile devices providing the same real-time visualization of vital signals of its desktop counterpart. The monitoring network communicates with the hospital network through a gateway using HL7 messages and has the ability to export waveforms in real time using the multicast protocol through an API library. A dedicated ActiveX component was built that establishes the streaming of the biomedical signals under monitoring and displays them on an Internet Explorer 5.x browser. The mobile version - called vMon-mobile - will parse the browser window and deliver it to a PDA device connected to a local area network. The result is a virtual monitor presenting real-time data on a mobile device. All parameters and signals acquired from the moment the patient is connected to the monitors are stored for a few days. The most clinically relevant information is added to patient's EPR.
Teaching in a Wireless Learning Environment: A Case Study
ERIC Educational Resources Information Center
Liu, Tzu Chien
2007-01-01
Although wireless and mobile technology is regarded as a useful tool for enhancing student-centered learning, few studies have explored the factors that may affect the application of this emerging technology in classroom situations. Accordingly, this study selects three factors (instructional belief, instructional routine, and features of wireless…
Enhancing Student Performance Using Tablet Computers
ERIC Educational Resources Information Center
Enriquez, Amelito G.
2010-01-01
Tablet PCs have the potential to change the dynamics of classroom interaction through wireless communication coupled with pen-based computing technology that is suited for analyzing and solving engineering problems. This study focuses on how tablet PCs and wireless technology can be used during classroom instruction to create an Interactive…
DOT National Transportation Integrated Search
2016-08-01
Micro-electromechanical sensors and systems- (MEMS)-based and : wireless-based smart-sensing technologies have, until now, rarely : been used for monitoring pavement response in the field, and the : requirements for using such smart sensing technolog...
NASA Astrophysics Data System (ADS)
Wang, Ning; Zhang, Di; Deng, Xinyu; Sun, Ying; Wang, Xinghua; Ma, Pinyi; Song, Daqian
2018-02-01
Herein we report a novel polydopamine-silver nanoparticle-polydopamine-gold (PDA-AgNPs-PDA-Au) film based surface plasmon resonance (SPR) biosensor for horse IgG detection. The PDA-AgNPs-PDA-Au film sensing platform was built on Au-film via layer-by-layer self-assembly. Ag ion was reduced in situ to AgNPs in presence of PDA. The top PDA layer can prevent AgNPs from being oxidized and connect with antibody via Schiff alkali reaction directly. The morphology and thickness of the modified gold film were characterized using scanning electron microscope and Talystep. Experimental results show that the PDA-AgNPs-PDA-Au film sensing platform is stable, regenerative and sensitive for horse IgG detection. The detection limit of horse IgG obtained with the present biosensor is 0.625 μg mL- 1, which is 2-fold and 4-fold lower than that obtained with biosensor based on PDA modified Au film and conventional biosensor based on MPA, respectively. Furthermore, when challenged to real serum samples, our sensor exhibited excellent specificity to horse IgG, suggesting its potential for industrial application.
NASA Astrophysics Data System (ADS)
Dasraf, D.; Djer, M. M.; Advani, N.
2017-08-01
Persistent ductus arteriosus is one of the most frequent congenital heart diseases found in infants, mainly in preterms. Echocardiography is the gold standard for the diagnosis of hemodynamically significant patent ductus arteriosus (hs-PDA) in preterm neonates. A few studies have suggested that the use of a simple blood assay to detect N-terminal pro-brain natriuretic peptide (NT-proBNP) may be useful in determining the diagnosis and management of hs-PDA. No such studies have been conducted in Indonesia, although the assay kit and characteristics of the patient (gestational age and chronological age) influence the accuracy of NT-proBNP levels in determining hs-PDA. The aim of this study was to determine the association between the NT-proBNP level and the prevalence of hs-PDA in an Indonesian patient population. A cross-sectional study was conducted at Dr. Cipto Mangunkusumo Hospital. PDA was determined using echocardiography in 49 preterm neonates (gestational age <37 weeks and birthweight <2000 g). Subsequently, these patients were divided into three groups: non-PDA, non-hsPDA, and hs-PDA. The blood NT-proBNP level was then determined in the non-hsPDA and hs-PDA groups, and between-group differences were compared. Among the 49 neonates, 33 patients had PDA, and 16 of these had hs-PDA. The results revealed a significant association between the NT-proBNP level and hs-PDA (p < 0.001).
Path Calculation and Packet Translation for UAV Surveillance in Support of Wireless Sensor Networks
2006-09-01
AND PACKET TRANSLATION FOR UAV SURVEILLANCE IN SUPPORT OF WIRELESS SENSOR NETWORKS by Stephen Schall September 2006 Thesis Advisor...Calculation and Packet Translation for UAV Surveillance in Support of Wireless Sensor Networks 6. AUTHOR(S) Stephen Schall 5. FUNDING NUMBERS 7...200 words) Wireless Sensor Networks (WSNs) are a relatively new technology with many potential applications, including military and
Enhancement of observability and protection of smart power system
NASA Astrophysics Data System (ADS)
Siddique, Abdul Hasib
It is important for a modern power grid to be smarter in order to provide reliable and sustainable supply of electricity. Traditional way of receiving data from the wired system is a very old and outdated technology. For a quicker and better response from the electric system, it is important to look at wireless systems as a feasible option. In order to enhance the observability and protection it is important to integrate wireless technology with the modern power system. In this thesis, wireless network based architecture for wide area monitoring and an alternate method for performing current measurement for protection of generators and motors, has been adopted. There are basically two part of this project. First part deals with the wide area monitoring of the power system and the second part focuses more on application of wireless technology from the protection point of view. A number of wireless method have been adopted in both the part, these includes Zigbee, analog transmission (Both AM and FM) and digital transmission. The main aim of our project was to propose a cost effective wide area monitoring and protection method which will enhance the observability and stability of power grid. A new concept of wireless integration in the power protection system has been implemented in this thesis work.
The Brave New World of Wireless Technologies: A Primer for Educators.
ERIC Educational Resources Information Center
Boerner, Gerald L.
2002-01-01
Discusses the use of wireless local area networks (WLANs) on college campuses. Highlights include traditional wired networks; cost, speed, and reliability; wireless networking standards; mobility; installation speed, simplicity, and flexibility; reduced cost of ownership; scalability; security issues; and a glossary of WLAN terms. (LRW)
Shipboard Wireless Sensor Networks Utilizing Zigbee Technology
2006-09-01
This thesis studies the feasibility of utilizing Zigbee standard devices to create a shipboard wireless sensor network . Two primary methods were used...the research effort would be a completely wireless sensor network which would result in a net savings in man hours required to maintain and monitor
NASA Astrophysics Data System (ADS)
Pinithchaisakula, A.; Ounnunkad, K.; Themsirimongkon, S.; Promsawan, N.; Waenkaew, P.; Saipanya, S.
2017-02-01
In this work, the preparation, characterization, and electrocatalytic analysis of the catalysts on various carbon substrates for direct alcohol fuel cells were studied. Selected carbons were modified with/without polydopamine (labelled as PDA-C and C) and further metal electrodeposited incorporated onto the glassy carbon (labelled as 5Pt1Pd/PDA-C and 5Pt1Pd/C). Four various carbon materials were used e.g. graphite (G), carbon nanotube (CNT), graphene (GP) and graphene oxide (GO) and the carbons were modified with PDA denoted as PDA-G, PDA-CNT, PDA-GP and PDA-GO, respectively. The transmission electron microscopy (TEM) and scanning electron microscopy (SEM) experimental observation showed narrow size distribution of metal anchored on the PDA-C and C materials. Chemical compositions and oxidation states of the catalysts were determined by X-ray photoelectron spectroscopy (XPS) and energy-dispersive X-ray spectroscopy (EDX). The catalytic performances for small organic electro-oxidation (e.g. methanol and ethanol) were measured by cyclic voltammetry (CV). Among different PDA-C and C catalysts, monometallic Pt showed less activity than the bimetallic catalysts. Among catalysts with PDA, the 5Pt1Pd/PDA-GO catalyst facilitated methanol and ethanol oxidations with high oxidation currents and If/Ib value and stability with low potentials while among catalysts without PDA, the 5Pt1Pd/CNT provides highest activity and stability. It was found that the catalysts with PDA provided high activity and stability than the catalysts without PDA. The improved catalytic performance of the prepared catalysts could be related to the higher active surface area from polymer modification and bimetallic catalyst system in the catalyst composites.
Shafi, Nabil A; Singh, Gagan D; Smith, Thomas W; Rogers, Jason H
2018-05-01
To describe a novel balloon sizing technique used during adult transcatheter patent ductus arteriosus (PDA) closure. In addition, to determine the clinical and procedural outcomes in six patients who underwent PDA balloon sizing with subsequent deployment of a PDA occluder device. Transcatheter PDA closure in adults has excellent safety and procedural outcomes. However, PDA sizing in adults can be challenging due to variable defect size, high flow state, or anatomical complexity. We describe a series of six cases where the balloon- pull through technique was successfully performed for PDA sizing prior to transcatheter closure. Consecutive adult patients undergoing adult PDA closure at our institution were studied retrospectively. A partially inflated sizing balloon was pulled through the defect from the aorta into the pulmonary artery and the balloon waist diameter was measured. Procedural success and clinical outcomes were obtained. Six adult patients underwent successful balloon pull-through technique for PDA sizing during transcatheter PDA closure, since conventional angiography often gave suboptimal opacification of the defect. All PDAs were treated with closure devices based on balloon PDA sizing with complete closure and no complications. In three patients that underwent preprocedure computed tomography, the balloon size matched the CT derived measurements. The balloon pull-through technique for PDA sizing is a safe and accurate sizing modality in adults undergoing transcatheter PDA closure. © 2017 Wiley Periodicals, Inc.
ERIC Educational Resources Information Center
Gentry, Tony; Kriner, Richard; Sima, Adam; McDonough, Jennifer; Wehman, Paul
2015-01-01
Personal digital assistants (PDAs) are versatile task organizers that hold promise as assistive technologies for people with cognitive-behavioral challenges. This delayed randomized controlled trial compared two groups of adult workers with autism spectrum disorder (ASD) to determine whether the use of an Apple iPod Touch PDA as a vocational…
Shed a light of wireless technology on portable mobile design of NIRS
NASA Astrophysics Data System (ADS)
Sun, Yunlong; Li, Ting
2016-03-01
Mobile internet is growing rapidly driven by high-tech companies including the popular Apple and Google. The wireless mini-NIRS is believed to deserve a great spread future, while there is sparse report on wireless NIRS device and even for the reported wireless NIRS, its wireless design is scarcely presented. Here we focused on the wireless design of NIRS devices. The widely-used wireless communication standards and wireless communication typical solutions were employed into our NIRS design and then compared on communication efficiency, distance, error rate, low-cost, power consumption, and stabilities, based on the requirements of NIRS applications. The properly-performed wireless communication methods matched with the characteristics of NIRS are picked out. Finally, we realized one recommended wireless communication in our NIRS, developed a test platform on wireless NIRS and tested the full properties on wireless communication. This study elaborated the wireless communication methods specified for NIRS and suggested one implementation with one example fully illustrated, which support the future mobile design on NIRS devices.
Supporting evidence-based practice for nurses through information technologies.
Doran, Diane M; Haynes, R Brian; Kushniruk, André; Straus, Sharon; Grimshaw, Jeremy; Hall, Linda McGillis; Dubrowski, Adam; Di Pietro, Tammie; Newman, Kristine; Almost, Joan; Nguyen, Ha; Carryer, Jennifer; Jedras, Dawn
2010-03-01
To evaluate the usability of mobile information terminals, such as personal digital assistants (PDAs) or Tablet personal computers, to improve access to information resources for nurses and to explore the relationship between PDA or Tablet-supported information resources and outcomes. The authors evaluated an initiative of the Nursing Secretariat, Ontario Ministry of Health and Long-Term Care, which provided nurses with PDAs and Tablet PCs, to enable Internet access to information resources. Nurses had access to drug and medical reference information, best practice guidelines (BPGs), and to abstracts of recent research studies. The authors took place over a 12-month period. Diffusion of Innovation theory and the Promoting Action on Research Implementation in Health Services (PARIHS) model guided the selection of variables for study. A longitudinal design involving questionnaires was used to evaluate the impact of the mobile technologies on barriers to research utilization, perceived quality of care, and on nurses' job satisfaction. The setting was 29 acute care, long-term care, home care, and correctional organizations in Ontario, Canada. The sample consisted of 488 frontline-nurses. Nurses most frequently consulted drug and medical reference information, Google, and Nursing PLUS. Overall, nurses were most satisfied with the Registered Nurses Association of Ontario (RNAO) BPGs and rated the RNAO BPGs as the easiest resource to use. Among the PDA and Tablet users, there was a significant improvement in research awareness/values, and in communication of research. There was also, for the PDA users only, a significant improvement over time in perceived quality of care and job satisfaction, but primarily in long-term care settings. It is feasible to provide nurses with access to evidence-based practice resources via mobile information technologies to reduce the barriers to research utilization.
Reduced cost alternatives to premise wiring using ATM and microcellular technologies
NASA Technical Reports Server (NTRS)
Gejji, Raghvendra R.
1993-01-01
The cost of premises wiring keeps increasing due to personnel moves, new equipment, capacity upgrades etc. It would be desirable to have a wireless interface from the workstations to the fixed network, so as to minimize the wiring changes needed. New technologies such as microcellular personal communication systems are promising to bring down the cost of wireless communication. Another promising technology is Code Division Multiple Access (CDMA), which could dramatically increase the bandwidth available for wireless connections. In addition, Asynchronous Transfer Mode (ATM) technology is emerging as a technique for integrated management of voice, data, and video traffic on a single network. The focus of this investigation will be to assess the future utility of these new technologies for reducing the premise wiring cost at KSC. One of the issues to be studied is the cost comparison of 'old' versus 'new,' especially as time and technology progress. An additional issue for closer study is a feasible time-line for progress in technological capability.
Terek, Demet; Yalaz, Mehmet; Ulger, Zulal; Koroglu, Ozge Altun; Kultursay, Nilgun
2014-01-01
Background: Although, patent ductus arteriosus (PDA) is associated with significant morbidity due to hemodynamic instability in preterm infants, the effect of ductus closure on mortality and morbidity is a controversial issue. The aim is to evaluate the efficacy of oral and intravenous (IV) ibuprofen treatment on ductal closure and effects on mortality and bronchoplumonary dysplasia. Materials and Methods: The medical records of 292 premature infants treated at Ege University Neonatal Intensive Care Unit were retrospectively evaluated. Patients were classified into 3 groups as; No PDA, hemodynamically insignificant PDA (hiPDA) and hemodynamically significant PDA (hsPDA) according to the presence and hemodynamical significance of PDA by echocardiography. hsPDA group was treated with IV or oral ibuprofen. Results: Patent ductus arteriosus was diagnosed by routine echocardiography in 145 patients, of whom 78 (53.7%) had hsPDA. All 65 infants with hiPDA had spontaneous PDA closure. Echocardiographic measurements were similar to those patients treated with oral or IV ibuprofen, as in the response rate to treatment without serious adverse effects. The presence of respiratory distress syndrome, surfactant therapy, late sepsis, bronchopulmonary dysplasia (BPD) and mortality rates were significantly higher in patients with hsPDA. However, with stepwise logistic regression; 5th min Apgar score (odds ratio [OR], 1.321, 95% confidence interval [CI], 1.063-1.641, P = 0.012) and gestational age (OR, 1.422, 95% CI, 1.212-1.662, P < 0.001) were the only significant variables associated with mortality. Gestational age (OR, 0.680, 95% CI, 0.531-0.871, P = 0.002) was the only significant variable associated with BPD shown with logistic regression. Conclusion: Ibuprofen treatment is effective for hsPDA closure with minimal side effects. HiPDA can close spontaneously; therefore treatment decision should be individualized. However, medical treatment of PDA does not reduce mortality and BPD. PMID:25657754
Terek, Demet; Yalaz, Mehmet; Ulger, Zulal; Koroglu, Ozge Altun; Kultursay, Nilgun
2014-11-01
Although, patent ductus arteriosus (PDA) is associated with significant morbidity due to hemodynamic instability in preterm infants, the effect of ductus closure on mortality and morbidity is a controversial issue. The aim is to evaluate the efficacy of oral and intravenous (IV) ibuprofen treatment on ductal closure and effects on mortality and bronchoplumonary dysplasia. The medical records of 292 premature infants treated at Ege University Neonatal Intensive Care Unit were retrospectively evaluated. Patients were classified into 3 groups as; No PDA, hemodynamically insignificant PDA (hiPDA) and hemodynamically significant PDA (hsPDA) according to the presence and hemodynamical significance of PDA by echocardiography. hsPDA group was treated with IV or oral ibuprofen. Patent ductus arteriosus was diagnosed by routine echocardiography in 145 patients, of whom 78 (53.7%) had hsPDA. All 65 infants with hiPDA had spontaneous PDA closure. Echocardiographic measurements were similar to those patients treated with oral or IV ibuprofen, as in the response rate to treatment without serious adverse effects. The presence of respiratory distress syndrome, surfactant therapy, late sepsis, bronchopulmonary dysplasia (BPD) and mortality rates were significantly higher in patients with hsPDA. However, with stepwise logistic regression; 5(th) min Apgar score (odds ratio [OR], 1.321, 95% confidence interval [CI], 1.063-1.641, P = 0.012) and gestational age (OR, 1.422, 95% CI, 1.212-1.662, P < 0.001) were the only significant variables associated with mortality. Gestational age (OR, 0.680, 95% CI, 0.531-0.871, P = 0.002) was the only significant variable associated with BPD shown with logistic regression. Ibuprofen treatment is effective for hsPDA closure with minimal side effects. HiPDA can close spontaneously; therefore treatment decision should be individualized. However, medical treatment of PDA does not reduce mortality and BPD.
Campbell, Robert J; Durigon, Louis
2003-01-01
Increasingly, health care professionals will need to retrieve, store, share, and send data using several types of wireless devices. These devices include personal digital assistants, laptops, Web tablets, cell phones, and clothing that monitor heart rate and blood pressure. Regardless of the device, several standards will vie for the right to provide the wireless communications link between the health care professional and the wired data resources located within a health care organization. This article identifies the top three technologies in the wireless communications field: Wireless Fidelity (WiFi), Mobile Communications, and Bluetooth; breaks down each according to its strengths and weaknesses; and makes recommendations for their use by health care professionals located inside and outside a health care facility. Where appropriate the discussion includes an explication of how a specific technology can be made secure from hackers and other security breeches.
Bosma, Laine; Balen, Robert M; Davidson, Erin; Jewesson, Peter J
2003-01-01
The development and integration of a personal digital assistant (PDA)-based point-of-care database into an intravenous resource nurse (IVRN) consultation service for the purposes of consultation management and service characterization are described. The IVRN team provides a consultation service 7 days a week in this 1000-bed tertiary adult care teaching hospital. No simple, reliable method for documenting IVRN patient care activity and facilitating IVRN-initiated patient follow-up evaluation was available. Implementation of a PDA database with exportability of data to statistical analysis software was undertaken in July 2001. A Palm IIIXE PDA was purchased and a three-table, 13-field database was developed using HanDBase software. During the 7-month period of data collection, the IVRN team recorded 4868 consultations for 40 patient care areas. Full analysis of service characteristics was conducted using SPSS 10.0 software. Team members adopted the new technology with few problems, and the authors now can efficiently track and analyze the services provided by their IVRN team.
An Overview of the Development of High Temperature Wireless Smart Sensor Technology
NASA Technical Reports Server (NTRS)
Hunter, Gary W.
2014-01-01
The harsh environment inherent in propulsion systems is especially challenging for Smart Sensor Systems; this paper addresses technology development for such applications. A basic sensing system for high temperature wireless pressure monitoring composed of a sensor, electronics, and wireless communication with scavenged power developed for health monitoring of aircraft engines and other high temperature applications has been demonstrated at 475 C. Other efforts will be discussed including a brief overview of the status of high temperature electronics and sensors, as well as their use and applications.
Guarascio-Howard, Linda
2011-01-01
A medical-surgical unit in a southwestern United States hospital examined the results of adding wireless communication technology to assist nurses in identifying patient bed status changes and enhancing team communication. Following the addition of wireless communication, response time to patient calls and the number of nurse-initiated communications were compared to pre-wireless calls and response time sampling period. In the baseline study, nurse-initiated communications and response time to patient calls were investigated for a team nursing model (Guarascio-Howard & Malloch, 2007). At this time, technology consisted of a nurse call system and telephones located at each decentralized nurse station and health unit coordinator (HUC) station. For this follow-up study, a wireless device was given to nurses and their team members following training on device use and privacy issues. Four registered nurses (RNs) were shadowed for 8 hours (32 hours total) before and after the introduction of the wireless devices. Data were collected regarding patient room visits, number of patient calls, bed status calls, response time to calls, and the initiator of the communication episodes. Follow-up study response time to calls significantly decreased (t-test p = .03). RNs and licensed practical nurses responded to bed status calls in less than 1 minute-62% of the 37 calls. Communication results indicated a significant shift (One Proportion Z Test) in RN-initiated communications, suggesting an enhanced ability to communicate with team members and to assist in monitoring patient status. Patient falls trended downward, although not significantly (p > .05), for a 6-month period of wireless technology use compared to the same period the previous year. The addition of a wireless device has advantages in team nursing, namely increasing communication with staff members and decreasing response time to patient and bed status calls. Limitations of the study included a change in caregiver team members and issues regarding wireless device and locator badge compliance. Administrative issues that arose during this field study included bed and cable maintenance, device battery charging, and the training of new and floating team members.
Home and School Technology: Wired versus Wireless.
ERIC Educational Resources Information Center
Van Horn, Royal
2001-01-01
Presents results of informal research on smart homes and appliances, structured home wiring, whole-house audio/video distribution, hybrid cable, and wireless networks. Computer network wiring is tricky to install unless all-in-one jacketed cable is used. Wireless phones help installers avoid pre-wiring problems in homes and schools. (MLH)
The Role of Wireless Computing Technology in the Design of Schools.
ERIC Educational Resources Information Center
Nair, Prakash
2003-01-01
After briefly describing the educational advantages of wireless networks using mobile computers, discusses the technical, operational, financial aspects of wireless local area networks (WLAN). Provides examples of school facilities designed for the use of WLAN. Includes a glossary of WLAN-related terms. (Contains 12 references.)
Mansano, Raul K; Godoy, Eduardo P; Porto, Arthur J V
2014-12-18
Recent advances in wireless networking technology and the proliferation of industrial wireless sensors have led to an increasing interest in using wireless networks for closed loop control. The main advantages of Wireless Networked Control Systems (WNCSs) are the reconfigurability, easy commissioning and the possibility of installation in places where cabling is impossible. Despite these advantages, there are two main problems which must be considered for practical implementations of WNCSs. One problem is the sampling period constraint of industrial wireless sensors. This problem is related to the energy cost of the wireless transmission, since the power supply is limited, which precludes the use of these sensors in several closed-loop controls. The other technological concern in WNCS is the energy efficiency of the devices. As the sensors are powered by batteries, the lowest possible consumption is required to extend battery lifetime. As a result, there is a compromise between the sensor sampling period, the sensor battery lifetime and the required control performance for the WNCS. This paper develops a model-based soft sensor to overcome these problems and enable practical implementations of WNCSs. The goal of the soft sensor is generating virtual data allowing an actuation on the process faster than the maximum sampling period available for the wireless sensor. Experimental results have shown the soft sensor is a solution to the sampling period constraint problem of wireless sensors in control applications, enabling the application of industrial wireless sensors in WNCSs. Additionally, our results demonstrated the soft sensor potential for implementing energy efficient WNCS through the battery saving of industrial wireless sensors.
High Fidelity Simulations of Large-Scale Wireless Networks
DOE Office of Scientific and Technical Information (OSTI.GOV)
Onunkwo, Uzoma; Benz, Zachary
The worldwide proliferation of wireless connected devices continues to accelerate. There are 10s of billions of wireless links across the planet with an additional explosion of new wireless usage anticipated as the Internet of Things develops. Wireless technologies do not only provide convenience for mobile applications, but are also extremely cost-effective to deploy. Thus, this trend towards wireless connectivity will only continue and Sandia must develop the necessary simulation technology to proactively analyze the associated emerging vulnerabilities. Wireless networks are marked by mobility and proximity-based connectivity. The de facto standard for exploratory studies of wireless networks is discrete event simulationsmore » (DES). However, the simulation of large-scale wireless networks is extremely difficult due to prohibitively large turnaround time. A path forward is to expedite simulations with parallel discrete event simulation (PDES) techniques. The mobility and distance-based connectivity associated with wireless simulations, however, typically doom PDES and fail to scale (e.g., OPNET and ns-3 simulators). We propose a PDES-based tool aimed at reducing the communication overhead between processors. The proposed solution will use light-weight processes to dynamically distribute computation workload while mitigating communication overhead associated with synchronizations. This work is vital to the analytics and validation capabilities of simulation and emulation at Sandia. We have years of experience in Sandia’s simulation and emulation projects (e.g., MINIMEGA and FIREWHEEL). Sandia’s current highly-regarded capabilities in large-scale emulations have focused on wired networks, where two assumptions prevent scalable wireless studies: (a) the connections between objects are mostly static and (b) the nodes have fixed locations.« less
NASA Astrophysics Data System (ADS)
Jian, Wei; Estevez, Claudio; Chowdhury, Arshad; Jia, Zhensheng; Wang, Jianxin; Yu, Jianguo; Chang, Gee-Kung
2010-12-01
This paper presents an energy-efficient Medium Access Control (MAC) protocol for very-high-throughput millimeter-wave (mm-wave) wireless sensor communication networks (VHT-MSCNs) based on hybrid multiple access techniques of frequency division multiplexing access (FDMA) and time division multiplexing access (TDMA). An energy-efficient Superframe for wireless sensor communication network employing directional mm-wave wireless access technologies is proposed for systems that require very high throughput, such as high definition video signals, for sensing, processing, transmitting, and actuating functions. Energy consumption modeling for each network element and comparisons among various multi-access technologies in term of power and MAC layer operations are investigated for evaluating the energy-efficient improvement of proposed MAC protocol.
ERIC Educational Resources Information Center
Briggs, Linda L.
2006-01-01
Wireless and mobile technologies are now everywhere, and 24/7 computing is as pervasive a term as the actual capability promises to be. Sometimes, in fact, the push toward mobile technologies can seem overwhelming. But every wireless project doesn't have to involve redesigning the network and investing in mega-dollars worth of hardware and…
An Introduction to Current Trends and Benefits of Mobile Wireless Technology Use in Higher Education
ERIC Educational Resources Information Center
Kim, Sang Hyun; Mims, Clif; Holmes, Kerry P.
2006-01-01
The development of mobile wireless technologies has generated a considerable amount of excitement among practitioners and academics because it results in shifting the academic environment from traditional settings to mobile learning (m-learning) settings. Increasing numbers of institutions of higher education offer courses using mobile wireless…
M-Learning: An Experiment in Using SMS to Support Learning New English Language Words
ERIC Educational Resources Information Center
Cavus, Nadire; Ibrahim, Dogan
2009-01-01
There is an increase use of wireless technologies in education all over the world. In fact, wireless technologies such as laptop computers, palmtop computers and mobile phones are revolutionizing education and transforming the traditional classroom-based learning and teaching into "anytime" and "anywhere" education. This paper investigates the use…
Implementing Wireless Mobile Instructional Labs: Planning Issues and Case Study
ERIC Educational Resources Information Center
McKimmy, Paul B.
2005-01-01
In April 2002, the Technology Advisory Committee of the University of Hawaii-Manoa College of Education (COE) prioritized the upgrade of existing instructional computer labs. Following several weeks of research and discussion, a decision was made to support wireless and mobile technologies during the upgrade. In June 2002, the first of three…
ERIC Educational Resources Information Center
Juliano, Benjoe A.; Sheel, Stephen J.
In this paper, potential applications of wireless data communications and mobile satellite technology are described which aim at improving education. The motivation behind this work is that the technology now exists for providing today's teachers and students with not only better access to educational facilities, but also instantaneous…
Introduction and comparison of next-generation mobile wireless technologies
NASA Astrophysics Data System (ADS)
Zaidi, Syed R.; Hussain, Shahab; Ali, M. A.; Sana, Ajaz; Saddawi, Samir; Carranza, Aparicio
2010-01-01
Mobile networks and services have gone further than voice-only communication services and are rapidly developing towards data-centric services. Emerging mobile data services are expected to see the same explosive growth in demand that Internet and wireless voice services have seen in recent years. To support such a rapid increase in traffic, active users, and advanced multimedia services implied by this growth rate along with the diverse quality of service (QoS) and rate requirements set by these services, mobile operator need to rapidly transition to a simple and cost-effective, flat, all IP-network. This has accelerated the development and deployment of new wireless broadband access technologies including fourth-generation (4G) mobile WiMAX and cellular Long-Term Evolution (LTE). Mobile WiMAX and LTE are two different (but not necessarily competing) technologies that will eventually be used to achieve data speeds of up to 100 Mbps. Speeds that are fast enough to potentially replace wired broadband connections with wireless. This paper introduces both of these next generation technologies and then compares them in the end.
Ubiquitous wireless ECG recording: a powerful tool physicians should embrace.
Saxon, Leslie A
2013-04-01
The use of smart phones has increased dramatically and there are nearly a billion users on 3G and 4G networks worldwide. Nearly 60% of the U.S. population uses smart phones to access the internet, and smart phone sales now surpass those of desktop and laptop computers. The speed of wireless communication technology on 3G and 4G networks and the widespread adoption and use of iOS equipped smart phones (Apple Inc., Cupertino, CA, USA) provide infrastructure for the transmission of wireless biomedical data, including ECG data. These technologies provide an unprecedented opportunity for physicians to continually access data that can be used to detect issues before symptoms occur or to have definitive data when symptoms are present. The technology also greatly empowers and enables the possibility for unprecedented patient participation in their own medical education and health status as well as that of their social network. As patient advocates, physicians and particularly cardiac electrophysiologists should embrace the future and promise of wireless ECG recording, a technology solution that can truly scale across the global population. © 2013 Wiley Periodicals, Inc.
Lindquist, Anna M; Johansson, Pauline E; Petersson, Göran I; Saveman, Britt-Inger; Nilsson, Gunilla C
2008-10-28
Health care personnel need access to updated information anywhere and at any time, and a Personal Digital Assistant (PDA) has the potential to meet these requirements. A PDA is a mobile tool which has been employed widely for various purposes in health care practice, and the level of its use is expected to increase. Loaded with suitable functions and software applications, a PDA might qualify as the tool that personnel and students in health care need. In Sweden today, despite its leadership role in mobile technologies, PDAs are not commonly used, and there is a lack of suitable functions and software applications. The aim of the present review was to obtain an overview of existing research on the use of PDAs among personnel and students in health care. The literature search included original peer-reviewed research articles written in English and published from 1996 to 2008. All study designs were considered for inclusion. We excluded reviews and studies focusing on the use of PDAs in classroom situations. From March 2006 to the last update in May 2008, we searched PubMed, CINAHL, Cochrane, IngentaConnect, and a local search engine (ELIN@Kalmar). We conducted a content analysis, using Nielsen's Model of System Acceptability as a theoretical framework in structuring and presenting the results. From the 900 references initially screened, 172 articles were selected and critically assessed until 48 articles remained. The majority originated in North-America (USA: n=24, Canada: n=11). The categories which emerged from our content analysis coincided to a certain extent to Nielsen's Model of System Acceptability (social and practical acceptability), including usefulness (utility and usability) subcategories such as learnability, efficiency, errors, and satisfaction. The studies showed that health care personnel and students used PDAs in patient care with varied frequency. Most of the users were physicians. There is some evidence that the use of a PDA in health care settings might improve decision-making, reduce the numbers of medical errors, and enhance learning for both students and professionals, but the evidence is not strong, with most studies being descriptive, and only 6 randomized controlled trials. Several special software programs have been created and tested for PDAs, and a wide range of situations for their use have been reported for different patient groups. Drug and medical information were commonly accessed by PDA users, and the PDA was often viewed as the preferred tool when compared to paper-based documents. Some users regarded the PDA easy to operate, while others found it difficult in the beginning. This overview of the use of PDAs revealed a positive attitude towards the PDA, which was regarded as a feasible and convenient tool. The possibility of immediate access to medical information has the potential to improve patient care. The PDA seems to be a valuable tool for personnel and students in health care, but there is a need for further intervention studies, randomized controlled trials, action research, and studies with various health care groups in order to identify its appropriate functions and software applications.
Lindquist, Anna M; Petersson, Göran I; Saveman, Britt-Inger; Nilsson, Gunilla C
2008-01-01
Background Health care personnel need access to updated information anywhere and at any time, and a Personal Digital Assistant (PDA) has the potential to meet these requirements. A PDA is a mobile tool which has been employed widely for various purposes in health care practice, and the level of its use is expected to increase. Loaded with suitable functions and software applications, a PDA might qualify as the tool that personnel and students in health care need. In Sweden today, despite its leadership role in mobile technologies, PDAs are not commonly used, and there is a lack of suitable functions and software applications. Objective The aim of the present review was to obtain an overview of existing research on the use of PDAs among personnel and students in health care. Methods The literature search included original peer-reviewed research articles written in English and published from 1996 to 2008. All study designs were considered for inclusion. We excluded reviews and studies focusing on the use of PDAs in classroom situations. From March 2006 to the last update in May 2008, we searched PubMed, CINAHL, Cochrane, IngentaConnect, and a local search engine (ELIN@Kalmar). We conducted a content analysis, using Nielsen’s Model of System Acceptability as a theoretical framework in structuring and presenting the results. Results From the 900 references initially screened, 172 articles were selected and critically assessed until 48 articles remained. The majority originated in North-America (USA: n=24, Canada: n=11). The categories which emerged from our content analysis coincided to a certain extent to Nielsen’s Model of System Acceptability (social and practical acceptability), including usefulness (utility and usability) subcategories such as learnability, efficiency, errors, and satisfaction. The studies showed that health care personnel and students used PDAs in patient care with varied frequency. Most of the users were physicians. There is some evidence that the use of a PDA in health care settings might improve decision-making, reduce the numbers of medical errors, and enhance learning for both students and professionals, but the evidence is not strong, with most studies being descriptive, and only 6 randomized controlled trials. Several special software programs have been created and tested for PDAs, and a wide range of situations for their use have been reported for different patient groups. Drug and medical information were commonly accessed by PDA users, and the PDA was often viewed as the preferred tool when compared to paper-based documents. Some users regarded the PDA easy to operate, while others found it difficult in the beginning. Conclusions This overview of the use of PDAs revealed a positive attitude towards the PDA, which was regarded as a feasible and convenient tool. The possibility of immediate access to medical information has the potential to improve patient care. The PDA seems to be a valuable tool for personnel and students in health care, but there is a need for further intervention studies, randomized controlled trials, action research, and studies with various health care groups in order to identify its appropriate functions and software applications. PMID:18957381
Moloney, Clint; Becarria, Lisa
It is clear from the literature that more investigation into the infusion of this technology within nursing is required with a particular emphasis on the advantages of documenting best practices in nursing education. Current literature highlights the importance of incorporating wireless devices in nursing organisations without discussing how effectively nurses can collect data. Good information is found on the factors of adoption and barriers associated with such devices in nursing however the evidence supplied in such findings is yet to be well substantiated. Therefore, this study conducted an investigation into the factors of adoption of wireless applications for data collection. By doing so, this review has attempted to fill-in the gap in the literature and provides insights into those factors that need to be given priority when implementing handheld technologies in nursing. The overarching aim of this systematic review was therefore to explore and confirm the facilitators and inhibitors to the adoption of handheld technology in nursing. The objective of this review was to summarise the available evidence on the facilitators and inhibitors of adopting and utilising handheld wireless technology into the nursing profession. In particular this review set out to understand the supportive interventions that assist nurses to adjust to the use of such technology. Types of participants - This review was only interested in the nursing profession and was not limited to any one culture or setting. Therefore the review included nurses both Australian and overseas who were working in acute settings, community settings, and student nurses still in an academic setting.Types of intervention(s)/phenomena of interest - The review only considered studies that were endeavouring to understand the behavioural intention and user acceptance of handheld wireless technology (PDA's) in a nursing setting.Types of studies - This review considered studies that focus on qualitative data including, but not limited to, designs such as phenomenology, ground theory, ethnography, action research and feminist research.Types of outcomes - Outcomes of interest were a strong reflection on the perception of nurses towards the technology and an identification of the major inhibitors and facilitators in adoption and utilisation of the technology. A three-step search strategy was utilised in each component of this review. An initial limited search of MEDLINE and CINAHL was undertaken followed by analysis of the text words contained in the title and abstract, and of the index terms used to describe article. A second search using all identified keywords and index terms was then undertaken across all included databases. Thirdly, the reference list of all identified reports and articles was searched for additional studies. Each paper was assessed by two reviewers for methodological quality prior to inclusion in the review using a critical appraisal instrument from Joanna Briggs Institute-Qualitative Assessment and Review Instrument (JBI-QARI) software developed by the Joanna Briggs Institute (JBI), (). Qualitative data was extracted from papers included in the review using the standardised data extraction tool from the JBI-QARI (). The JBI Qualitative Assessment and Review Instrument (JBI-QARI) was utilised to merge similar findings into categories and then similar categories were again narrowed down to a common generic concept. A total of 18 papers were retrieved. Of these, 11 were included in the review with all 11 being qualitative research papers. Reasons for the 7 papers being excluded from the review, were because experiences of nurses were not addressed (7 papers); the definition of nurse did not fit the inclusion criteria (2 papers); the concept "Nurses utilising PDAs" was not completely clear (1 paper). In addition all 7 of these papers were also excluded because of poor or incomplete descriptions of the methodology following critical appraisal using the JBI-QARI critical appraisal tool. The findings of the remaining 11 papers were extracted and combined in the meta-synthesis. Key findings in this review included: The saving of nursing time; both advantages and disadvantage in assisting with information flow; the assistance of the technology with nurse decision making; varied opinions on the usability of the technology; positive links to nursing support; innovation diffusion considerations; and positive results on the use of the technology as an effective learning tool. Findings of this systematic review provide sound evidence that information flow and real-time nurse decision making are enhanced with the use of PDAs in a clinical setting. What is clear is the technology can play a particularly important role in the pre-registered population of nurses still undergoing their training. Nursing support for this cohort would appear fundamental and hence the additional support given by using such technology would appear to enhance critical thinking skills and an ability to analyse evidence based practice information.Wireless connectively to the World Wide Web can expand the breadth of information made available to nursing staff and promote a safer and more therapeutic environment. The role PDAs may have in providing a safer medication administration environment for nurses needs to be investigated in greater depth. Issues of innovation diffusion require significant attention and manufacturers of these devices need to work with the nursing profession to find the most suitable design for a busy clinical setting. E-learning through the use of such technology would appear to have great potential and increase a nurse's exposure to education resources. This would seem of great benefit to student nurses in the academic sector.
Mobile technology use in medical education.
Luanrattana, Rattiporn; Win, Khin Than; Fulcher, John; Iverson, Don
2012-02-01
This study was undertaken to determine the PDA functionalities for a problem-based learning (PBL) medical curriculum at the Graduate School of Medicine (GSM), the University of Wollongong (UOW). The study determines the factors/aspects of incorporating PDAs, and the attitudes of stakeholders regarding the use of PDAs in such a PBL-based medical curriculum. In-depth interviews were designed and conducted with medical faculty, the medical education technology team and honorary medical academics. Four major PDA functionalities were identified, these being: clinical-log, reference, communication, and general functions. Two major aspects for the incorporation of PDAs into the PBL-medical curriculum at the UOW were determined from the interviews, these being technical and practical aspects. There is a potential for PDAs to be incorporated into the PBL-medical curricula at the UOW. However, a clear strategy needs to be defined as to how best to incorporate PDAs into PBL-medical curricula with minimal impact on students, as well as financial and resource implications for the GSM.
Avionics Architectures for Exploration: Wireless Technologies and Human Spaceflight
NASA Technical Reports Server (NTRS)
Goforth, Montgomery B.; Ratliff, James E.; Barton, Richard J.; Wagner, Raymond S.; Lansdowne, Chatwin
2014-01-01
The authors describe ongoing efforts by the Avionics Architectures for Exploration (AAE) project chartered by NASA's Advanced Exploration Systems (AES) Program to evaluate new avionics architectures and technologies, provide objective comparisons of them, and mature selected technologies for flight and for use by other AES projects. The AAE project team includes members from most NASA centers and from industry. This paper provides an overview of recent AAE efforts, with particular emphasis on the wireless technologies being evaluated under AES to support human spaceflight.
Hamamura, Kensuke; Yanagida, Mitsuaki; Ishikawa, Hitoshi; Banzai, Michio; Yoshitake, Hiroshi; Nonaka, Daisuke; Tanaka, Kenji; Sakuraba, Mayumi; Miyakuni, Yasuka; Takamori, Kenji; Nojima, Michio; Yoshida, Koyo; Fujiwara, Hiroshi; Takeda, Satoru; Araki, Yoshihiko
2018-03-01
Purpose We previously attempted to develop quantitative enzyme-linked immunosorbent assay (ELISA) systems for the PDA039/044/071 peptides, potential serum disease biomarkers (DBMs) of pregnancy-induced hypertension (PIH), primarily identified by a peptidomic approach (BLOTCHIP®-mass spectrometry (MS)). However, our methodology did not extend to PDA071 (cysteinyl α2-HS-glycoprotein 341-367 ), due to difficulty to produce a specific antibody against the peptide. The aim of the present study was to establish an alternative PDA071 quantitation system using liquid chromatography-multiple reaction monitoring (LC-MRM)/MS, to explore the potential utility of PDA071 as a DBM for PIH. Methods We tested heat/acid denaturation methods in efforts to purify serum PDA071 and developed an LC-MRM/MS method allowing for specific quantitation thereof. We measured serum PDA071 concentrations, and these results were validated including by three-dimensional (3D) plotting against PDA039 (kininogen-1 439-456 )/044 (kininogen-1 438-456 ) concentrations, followed by discriminant analysis. Results PDA071 was successfully extracted from serum using a heat denaturation method. Optimum conditions for quantitation via LC-MRM/MS were developed; the assayed serum PDA071 correlated well with the BLOTCHIP® assay values. Although the PDA071 alone did not significantly differ between patients and controls, 3D plotting of PDA039/044/071 peptide concentrations and construction of a Jackknife classification matrix were satisfactory in terms of PIH diagnostic precision. Conclusions Combination analysis using both PDA071 and PDA039/044 concentrations allowed PIH diagnostic accuracy to be attained, and our method will be valuable in future pathophysiological studies of hypertensive disorders of pregnancy.
Zulqarnain, Arif; Younas, Muhammad; Waqar, Tariq; Beg, Ahsan; Asma, Touseef; Baig, Mirza Ahmad Raza
2016-01-01
Comparison of effectiveness and cost of transcatheter occlusion of patent ductus arteriosus (PDA) with surgical ligation of PDA. This retrospective comparative study was conducted in the pediatric cardiology department of Ch. Pervaiz Elahi Institute of Cardiology Multan, Pakistan. Data of 250 patients who underwent patent ductus arteriosus (PDA) closure either surgical or trans-catheter closure using SHSMA Occluder having weight >5 kg from April 2012 to October 2015 were included in this study. SPSS version 20 was used for data analysis. Quantitative variables were compared using independent sample t-test. Chi-square test and fishers exact was used for qualitative variables. P-value <0.05 was considered statistically significant. There were one hundred and twenty (120) patients who underwent transcatheter occlusion of PDA using SHSMA occluder (PDA Device Group) and one hundred and thirty (130) patients who underwent surgical ligation of PDA (Surgical Group). Incidence of residual shunting was two (1.5%) in surgical group and 0 (0.0%) in PDA Device group for one month follow up period. There were 4 (3.1%) major complications in surgical group. The rate of blood transfusions were high in surgical group (p-value 0.04). Hospital stay time was significantly less in PDA Device group (P-value <0.001). Total procedural cost was 110695+1054 Pakistani rupees in PDA Device group and 92414+3512 in surgical group (p-value <0.001). The cost of PDA device closure was 16.52% higher than the surgical ligation of PDA. There was no operative mortality. The transcatheter closure of PDA is an effective and less invasive method as compared to the surgical ligation. There is a lower rate of complications and the cost is not much high as compared to surgical PDA ligation.
Dundie, A; Hayes, G; Scrivani, P; Campoy, L; Fletcher, D; Ash, K; Oxford, E; Moïse, N S
2017-04-01
A 10 week old female intact Staffordshire terrier was presented with a total of five congenital cardio-thoracic vascular anomalies consisting of a patent ductus arteriosus (PDA) with an aneurysmic dilation, pulmonic stenosis, persistent right aortic arch, aberrant left subclavian artery and persistent left cranial vena cava. These abnormalities were identified with a combination of echocardiogram and computed tomography angiography (CTA). The abnormalities were associated with esophageal entrapment, regurgitation, and volume overload of the left heart with left atrial and ventricular enlargement. A 2 cm diameter aneurysmic dilation at the junction of the PDA, right aortic arch and aberrant left subclavian artery presented an unusual surgical challenge and precluded simple circumferential ligation and transection of the structure. A full scale three dimensional model of the heart and vasculature was constructed from the CTA and plasma sterilized. The model was used preoperatively to facilitate surgical planning and enhance intraoperative communication and coordination between the surgical and anesthesia teams. Intraoperatively the model facilitated spatial orientation, atraumatic vascular dissection, instrument sizing and positioning. A thoracoabdominal stapler was used to close the PDA aneurysm prior to transection. At the four-month postoperative follow-up the patient was doing well. This is the first reported application of new imaging and modeling technology to enhance surgical planning when approaching correction of complex cardiovascular anomalies in a dog. Copyright © 2016 Elsevier B.V. All rights reserved.
Wireless Roadside Inspection Proof of Concept Test Final Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Capps, Gary J; Franzese, Oscar; Knee, Helmut E
2009-03-01
The U.S. Department of Transportation (DOT) FMCSA commissioned the Wireless Roadside Inspection (WRI) Program to validate technologies and methodologies that can improve safety through inspections using wireless technologies that convey real-time identification of commercial vehicles, drivers, and carriers, as well as information about the condition of the vehicles and their drivers. It is hypothesized that these inspections will: -- Increase safety -- Decrease the number of unsafe commercial vehicles on the road; -- Increase efficiency -- Speed up the inspection process, enabling more inspections to occur, at least on par with the number of weight inspections; -- Improve effectiveness --more » Reduce the probability of drivers bypassing CMV inspection stations and increase the likelihood that fleets will attempt to meet the safety regulations; and -- Benefit industry -- Reduce fleet costs, provide good return-on-investment, minimize wait times, and level the playing field. The WRI Program is defined in three phases which are: Phase 1: Proof of Concept Test (POC) Testing of commercially available off-the-shelf (COTS) or near-COTS technology to validate the wireless inspection concept. Phase 2: Pilot Test Safety technology maturation and back office system integration Phase 3: Field Operational Test Multi-vehicle testing over a multi-state instrumented corridor This report focuses on Phase 1 efforts that were initiated in March, 2006. Technical efforts dealt with the ability of a Universal Wireless Inspection System (UWIS) to collect driver, vehicle, and carrier information; format a Safety Data Message Set from this information; and wirelessly transmit a Safety Data Message Set to a roadside receiver unit or mobile enforcement vehicle.« less
Clauson, Kevin A; Polen, Hyla H; Marsh, Wallace A
2007-12-01
To evaluate personal digital assistant (PDA) drug information databases used to support clinical decision-making, and to compare the performance of PDA databases with their online versions. Prospective evaluation with descriptive analysis. Five drug information databases available for PDAs and online were evaluated according to their scope (inclusion of correct answers), completeness (on a 3-point scale), and ease of use; 158 question-answer pairs across 15 weighted categories of drug information essential to health care professionals were used to evaluate these databases. An overall composite score integrating these three measures was then calculated. Scores for the PDA databases and for each PDA-online pair were compared. Among the PDA databases, composite rankings, from highest to lowest, were as follows: Lexi-Drugs, Clinical Pharmacology OnHand, Epocrates Rx Pro, mobileMicromedex (now called Thomson Clinical Xpert), and Epocrates Rx free version. When we compared database pairs, online databases that had greater scope than their PDA counterparts were Clinical Pharmacology (137 vs 100 answers, p<0.001), Micromedex (132 vs 96 answers, p<0.001), Lexi-Comp Online (131 vs 119 answers, p<0.001), and Epocrates Online Premium (103 vs 98 answers, p=0.001). Only Micromedex online was more complete than its PDA version (p=0.008). Regarding ease of use, the Lexi-Drugs PDA database was superior to Lexi-Comp Online (p<0.001); however, Epocrates Online Premium, Epocrates Online Free, and Micromedex online were easier to use than their PDA counterparts (p<0.001). In terms of composite scores, only the online versions of Clinical Pharmacology and Micromedex demonstrated superiority over their PDA versions (p>0.01). Online and PDA drug information databases assist practitioners in improving their clinical decision-making. Lexi-Drugs performed significantly better than all of the other PDA databases evaluated. No PDA database demonstrated superiority to its online counterpart; however, the online versions of Clinical Pharmacology and Micromedex were superior to their PDA versions in answering questions.
A Fast and Scalable Algorithm for Calculating the Achievable Capacity of a Wireless Mesh Network
2016-04-10
to interference from a given transmission . We then use our algorithm to perform a network capacity analysis comparing different wireless technologies...A Fast and Scalable Algorithm for Calculating the Achievable Capacity of a Wireless Mesh Network Greg Kuperman, Jun Sun, and Aradhana Narula-Tam MIT...the maximum achievable capacity of a multi-hop wireless mesh network subject to interference constraints. Being able to quickly determine the maximum
Highly Directive Reflect Array Antenna Design for Wireless Power Transfer
2017-04-14
AFRL-AFOSR-JP-TR-2017-0033 Highly Directive Reflect Array Antenna Design for Wireless Power Transfer Siddhartha Prakash Duttagupta INDIAN INSTITUTE...Directive Reflect Array Antenna Design for Wireless Power Transfer 5a. CONTRACT NUMBER 5b. GRANT NUMBER FA2386-14-1-4076 5c. PROGRAM ELEMENT NUMBER...Antenna Design for Wireless Power Principal Investigator: SP Duttagupta Email: sdgupta@ee.iitb.ac.in Institution: Indian Institute of Technology
Jacob, Eufemia; Pavlish, Carol; Duran, Joana; Stinson, Jennifer; Lewis, Mary Ann; Zeltzer, Lonnie
2013-01-01
Use of wireless devices has the potential to transform delivery of primary care services for persons with sickle cell disease (SCD). The study examined text message communications between patients and an advanced practice registered nurse (APRN) and the different primary care activities that emerged with use of wireless technology. Patients (N = 37; mean age 13.9 ± 1.8 years; 45.9% male and 54.1% female) engaged in intermittent text conversations with the APRN as part of the Wireless Pain Intervention Program. Content analyses were used to analyze the content of text message exchanges between patients and the APRN. The primary care needs that emerged were related to pain and symptom management and sickle cell crisis prevention. Two primary care categories (collaborating and coaching), four primary care subcategories (screening, referring, informing, and supporting), and 16 primary care activities were evident in text conversations. The use of wireless technology may facilitate screening, prompt management of pain and symptoms, prevention or reduction of SCD-related complications, more efficient referral for treatments, timely patient education, and psychosocial support in children and adolescents with SCD. Copyright © 2013 National Association of Pediatric Nurse Practitioners. Published by Mosby, Inc. All rights reserved.
Use of a wireless local area network in an orthodontic clinic.
Mupparapu, Muralidhar; Binder, Robert E; Cummins, John M
2005-06-01
Radiographic images and other patient records, including medical histories, demographics, and health insurance information, can now be stored digitally and accessed via patient management programs. However, digital image acquisition and diagnosis and treatment planning are independent tasks, and each is time consuming, especially when performed at different computer workstations. Networking or linking the computers in an office enhances access to imaging and treatment planning tools. Access can be further enhanced if the entire network is wireless. Thanks to wireless technology, stand-alone, desk-bound personal computers have been replaced with mobile, hand-held devices that can communicate with each other and the rest of the world via the Internet. As with any emerging technology, some issues should be kept in mind when adapting to the wireless environment. Foremost is network security. Second is the choice of mobile hardware devices that are used by the orthodontist, office staff, and patients. This article details the standards and choices in wireless technology that can be implemented in an orthodontic clinic and suggests how to select suitable mobile hardware for accessing or adding data to a preexisting network. The network security protocols discussed comply with HIPAA regulations and boost the efficiency of a modern orthodontic clinic.
NASA Technical Reports Server (NTRS)
DeCristofaro, Michael A.; Lansdowne, Chatwin A.; Schlesinger, Adam M.
2014-01-01
NASA has identified standardized wireless mesh networking as a key technology for future human and robotic space exploration. Wireless mesh networks enable rapid deployment, provide coverage in undeveloped regions. Mesh networks are also self-healing, resilient, and extensible, qualities not found in traditional infrastructure-based networks. Mesh networks can offer lower size, weight, and power (SWaP) than overlapped infrastructure-perapplication. To better understand the maturity, characteristics and capability of the technology, we developed an 802.11 mesh network consisting of a combination of heterogeneous commercial off-the-shelf devices and opensource firmware and software packages. Various streaming applications were operated over the mesh network, including voice and video, and performance measurements were made under different operating scenarios. During the testing several issues with the currently implemented mesh network technology were identified and outlined for future work.
Engineering fluorescent poly(dopamine) capsules.
Chen, Xi; Yan, Yan; Müllner, Markus; van Koeverden, Martin P; Noi, Ka Fung; Zhu, Wei; Caruso, Frank
2014-03-18
The recent development of poly(dopamine) (PDA) capsules provides new opportunities for their application in biology and medicine. To advance the biomedical application of PDA capsules, strategies that enable the preparation of fluorescently labeled PDA (F-PDA) capsules are required, as this will allow evaluation of their cellular interactions using a range of fluorescence-based techniques. Herein, we report a facile approach for the fabrication of F-PDA capsules via the polymerization of dopamine (DA) on sacrificial templates in the presence of hydrogen peroxide (H2O2). F-PDA capsules with well-defined sizes are prepared by templating different organic and inorganic particles. The resulting F-PDA capsules show negligible cytotoxicity in HeLa cells after incubation for 48 h. We also demonstrate visualization of the F-PDA capsules following internalization by HeLa cells using conventional fluorescence microscopy, en route toward detailed investigations on their biological interactions.
Launching a Wireless Laptop Program
ERIC Educational Resources Information Center
Grignano, Domenic
2007-01-01
In this article, the author, as a technology director for East Rock Magnet School in New Haven, Connecticut, a federal government test site for laptop learning, shares his secrets to a successful implementation of a wireless laptop program: (1) Build a wireless foundation; (2) Do not choose the cheapest model just because of budget; (3) A sturdy…
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
This guide provides federal facility managers with an overview of the energy savings potential of wireless lighting occupancy sensors for various room types, cost considerations, key steps to successful installation of wireless sensors, pros and cons of various technology options, light source considerations, and codes and standards.
Wireless system for monitoring Intra-abdominal pressure in patient with severe abdominal pathology
NASA Astrophysics Data System (ADS)
Sokolovskiy, S. S.; Shtotskiy, Y. V.; Leljanov, A. D.
2017-01-01
The paper discusses an experimental design of the wireless system for monitoring intra-abdominal pressure (IAP) using Bluetooth Low Energy technology. The possibility of measuring IAP via the bladder using a wireless pressure sensor with a hydrophobic bacteria filter between the liquid transmitting medium and the sensor element is grounded.
Towards Mitigating Heterogeneous Wireless Interference in Spectrum Bands with Unlicensed Access
ERIC Educational Resources Information Center
Nychis, George P.
2013-01-01
In the past two decades, we have seen an unprecedented rise in unlicensed wireless devices and applications of wireless technology. To meet various application constraints, we continually customize the radios and their protocols to the application domain which has led to significant diversity in spectrum use. Unfortunately, this diversity (coupled…
Kopec, Rachel E; Schweiggert, Ralf M; Riedl, Ken M; Carle, Reinhold; Schwartz, Steven J
2013-06-30
Bioavailability of essential lipophilic micronutrients and carotenoids is of utmost interest for human health, as the consumption of these compounds may help alleviate major nutritional deficiencies, cardiovascular disease, and cancer. High-performance liquid chromatography/photo-diode array detection (HPLC-PDA) and high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) were compared for the quantitative analysis of α- and β-carotene, β-cryptoxanthin, lutein, lycopene, α-tocopherol, phylloquinone, and several retinyl esters from chylomicron-containing triglyceride rich lipoprotein (TRL) fractions of human plasma obtained from two clinical trials. After selecting an efficient extraction method for the analytes, both the HPLC/PDA and the HPLC/MS/MS methods were developed and several parameters validated using an HP 1200 series HPLC system interfaced with a HP 1200 series diode-array detector (Agilent Technologies, Santa Clara, CA, USA) and a QTRAP 5500 (AB Sciex, Foster City, CA, USA) via an atmospheric pressure chemical ionization (APCI) probe operated in positive ion mode. For lycopene, α- and β-carotene, HPLC/MS/MS was up to 37 times more sensitive than HPLC-PDA. PDA detection was shown to be up to 8 times more sensitive for lutein. MS/MS signals were enhanced by matrix components for lutein and β-cryptoxanthin, as determined by referencing to the matrix-independent PDA signal. In contrast, matrix suppression was observed for retinyl palmitate, α-carotene, and β-carotene. Both detectors showed similar suitability for α-tocopherol, lycopene and retinyl palmitate (representing ~73% of total retinyl esters). MS/MS exclusively allowed the quantitation of minor retinyl esters, phylloquinone, and (Z)-lycopene isomers. HPLC/MS/MS was more sensitive than HPLC-PDA for six of the eight analytes and represents a powerful tool for the analysis of chylomicron samples and potentially other biological samples of limited sample size. When internal standards are available for the target carotenoid, employing MS/MS detection may reduce the necessary blood sample volume, which is particularly advantageous for minimizing risk and discomfort to human subjects during clinical studies. Copyright © 2013 John Wiley & Sons, Ltd.
Kopec, Rachel E.; Schweiggert, Ralf M.; Riedl, Ken M.; Carle, Reinhold; Schwartz, Steven J.
2013-01-01
Rationale Bioavailability of essential lipophilic micronutrients and carotenoids is of utmost interest for human health, as the consumption of these compounds may help alleviate major nutritional deficiencies, cardiovascular disease, and cancer. High-performance liquid chromatography/photo-diode array detection (HPLC-PDA) and high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) were compared for the quantitative analysis of α- and β-carotene, β-cryptoxanthin, lutein, lycopene, α-tocopherol, phylloquinone, and several retinyl esters from chylomicron-containing triglyceride rich lipoprotein (TRL) fractions of human plasma obtained from two clinical trials. Methods After selecting an efficient extraction method for the analytes, both the HPLC/PDA and the HPLC/MS/MS methods were developed and several parameters validated using an HP 1200 series HPLC system interfaced with a HP 1200 series diode-array detector (Agilent Technologies, Santa Clara, CA, USA) and a QTRAP 5500 (AB Sciex, Foster City, CA, USA) via an atmospheric pressure chemical ionization (APCI) probe operated in positive ion mode. Results For lycopene, α- and β-carotene, HPLC/MS/MS was up to 37 times more sensitive than HPLC-PDA. PDA detection was shown to be up to 8 times more sensitive for lutein. MS/MS signals were enhanced by matrix components for lutein and β-cryptoxanthin, as determined by referencing to the matrix-independent PDA signal. In contrast, matrix suppression was observed for retinyl palmitate, α-carotene, and β-carotene. Both detectors showed similar suitability for α-tocopherol, lycopene and retinyl palmitate (representing ~73% of total retinyl esters). MS/MS exclusively allowed the quantitation of minor retinyl esters, phylloquinone, and (Z)-lycopene isomers. Conclusions HPLC/MS/MS was more sensitive than HPLC-PDA for six of the eight analytes and represents a powerful tool for the analysis of chylomicron samples and potentially other biological samples of limited sample size. When internal standards are available for the target carotenoid, employing MS/MS detection may reduce the necessary blood sample volume, which is particularly advantageous for minimizing risk and discomfort to human subjects during clinical studies. PMID:23681818
Miniature and Molecularly Specific Optical Screening Technologies for Breast Cancer
2008-10-01
commercially available dual-channel transimpedance amplifier circuit boards (Boston Electronics, TWAMP). Preliminary results with the imaging probe...connected to a current amplifier via a coaxial cable for diffuse reflectance measurements. This new probe is named P4-3 and schematics of the system and...probe. With the single pixel device a single-channel current amplifier (Terahertz Technologies, PDA-750) could easily read and collect the photocurrent
NASA Astrophysics Data System (ADS)
Tong, Xiaohui; Liu, Jingao; Wang, Zhenghao; Wang, Shuxian
2004-03-01
This paper presents several key technologies in the Mobile Location Based Service (MLBS) system of Shanghai. In the paper, the author presents a solution of handset mobile terminal, PDA+GPS+GSM/GPRS. The paper particularly introduces the hardware of the terminal and the acquirement of GPS information at the terminal. The paper also introduces how the terminal communicates with the special service center.
``Low Power Wireless Technologies: An Approach to Medical Applications''
NASA Astrophysics Data System (ADS)
Bellido O., Francisco J.; González R., Miguel; Moreno M., Antonio; de La Cruz F, José Luis
Wireless communication supposed a great both -quantitative and qualitative, jump in the management of the information, allowing the access and interchange of it without the need of a physical cable connection. The wireless transmission of voice and information has remained in constant evolution, arising new standards like BluetoothTM, WibreeTM or ZigbeeTM developed under the IEEE 802.15 norm. These newest wireless technologies are oriented to systems of communication of short-medium distance and optimized for a low cost and minor consume, becoming recognized as a flexible and reliable medium for data communications across a broad range of applications due to the potential that the wireless networks presents to operate in demanding environments providing clear advantages in cost, size, power, flexibility, and distributed intelligence. About the medical applications, the remote health or telecare (also called eHealth) is getting a bigger place into the manufacturers and medical companies, in order to incorporate products for assisted living and remote monitoring of health parameteres. At this point, the IEEE 1073, Personal Health Devices Working Group, stablish the framework for these kind of applications. Particularly, the 1073.3.X describes the physical and transport layers, where the new ultra low power short range wireless technologies can play a big role, providing solutions that allow the design of products which are particularly appropriate for monitor people’s health with interoperability requirements.
An open and reconfigurable wireless sensor network for pervasive health monitoring.
Triantafyllidis, A; Koutkias, V; Chouvarda, I; Maglaveras, N
2008-01-01
Sensor networks constitute the backbone for the construction of personalized monitoring systems. Up to now, several sensor networks have been proposed for diverse pervasive healthcare applications, which are however characterized by a significant lack of open architectures, resulting in closed, non-interoperable and difficult to extend solutions. In this context, we propose an open and reconfigurable wireless sensor network (WSN) for pervasive health monitoring, with particular emphasis in its easy extension with additional sensors and functionality by incorporating embedded intelligence mechanisms. We consider a generic WSN architecture comprised of diverse sensor nodes (with communication and processing capabilities) and a mobile base unit (MBU) operating as the gateway between the sensors and the medical personnel, formulating this way a body area network (BAN). The primary focus of this work is on the intra-BAN data communication issues, adopting SensorML as the data representation mean, including the encoding of the monitoring patterns and the functionality of the sensor network. In our prototype implementation two sensor nodes are emulated; one for heart rate monitoring and the other for blood glucose observations, while the MBU corresponds to a personal digital assistant (PDA) device. Java 2 Micro Edition (J2ME) is used to implement both the sensor nodes and the MBU components. Intra-BAN wireless communication relies on the Blue-tooth protocol. Via an adaptive user interface in the MBU, health professionals may specify the monitoring parameters of the WSN and define the monitoring patterns of interest in terms of rules. This work constitutes an essential step towards the construction of open, extensible, inter-operable and intelligent WSNs for pervasive health monitoring.
Using PDA for Undergraduate Student Incidental Vocabulary Testing
ERIC Educational Resources Information Center
Song, Yanjie; Fox, Robert
2008-01-01
Recent studies have explored English vocabulary learning in environments where students used mobile technologies for prescribed vocabulary learning tasks, or tested designed personalized learning systems to enhance student vocabulary learning for short periods of time in language related courses. Dictionary use via mobile devices has mostly been…
Wireless Internet Gateways (WINGS)
1997-01-01
WIRELESS INTERNET GATEWAYS (WINGS) J.J. Garcia-Luna-Aceves, Chane L. Fullmer, Ewerton Madruga Computer Engineering Department University of...rooftop.com Abstract— Today’s internetwork technology has been extremely success- ful in linking huge numbers of computers and users. However, to date...this technology has been oriented to computer interconnection in relatively stable operational environments, and thus cannot adequately support many of
Convergence of broadband optical and wireless access networks
NASA Astrophysics Data System (ADS)
Chang, Gee-Kung; Jia, Zhensheng; Chien, Hung-Chang; Chowdhury, Arshad; Hsueh, Yu-Ting; Yu, Jianjun
2009-01-01
This paper describes convergence of optical and wireless access networks for delivering high-bandwidth integrated services over optical fiber and air links. Several key system technologies are proposed and experimentally demonstrated. We report here, for the first ever, a campus-wide field trial demonstration of radio-over-fiber (RoF) system transmitting uncompressed standard-definition (SD) high-definition (HD) real-time video contents, carried by 2.4-GHz radio and 60- GHz millimeter-wave signals, respectively, over 2.5-km standard single mode fiber (SMF-28) through the campus fiber network at Georgia Institute of Technology (GT). In addition, subsystem technologies of Base Station and wireless tranceivers operated at 60 GHz for real-time video distribution have been developed and tested.
NASA Astrophysics Data System (ADS)
Zhang, Zhe; Zhang, Jing; Zhang, Bailin; Tang, Jilin
2012-12-01
Mussels have been shown to attach to virtually all types of inorganic and organic surfaces via their adhesive proteins. The adhesive proteins secreted by mussels contain high concentrations of catechol and amine functional groups, which have similar functional groups with polydopamine (PDA). Inspired by mussels, a mild and environmentally friendly method was used to synthesize Ag nanoparticles (Ag NPs) on functionalized PDA-graphene nanosheets (PDA-GNS) with uniform and high dispersion. First, a uniform layer of PDA was coated on graphene oxide (GO) by polymerizing dopamine (DA) at room temperature. During the process GO was reduced by the DA. The PDA layer on the surface of GNS can be used as a nanoscale guide to form uniform Ag NPs on the surface of PDA-GNS. The obtained Ag-PDA-GNS hybrid materials are characterized by atomic force microscopy, transmission electron microscopy, UV-vis spectroscopy, Raman spectroscopy, X-ray photo-electron spectroscopy, X-ray diffraction, and thermal gravimetric analysis. The resultant Ag-PDA-GNS hybrid materials exhibited strong antibacterial properties to both Gram-negative and Gram-positive bacteria due to the synergistic effect of GNS and Ag NPs.Mussels have been shown to attach to virtually all types of inorganic and organic surfaces via their adhesive proteins. The adhesive proteins secreted by mussels contain high concentrations of catechol and amine functional groups, which have similar functional groups with polydopamine (PDA). Inspired by mussels, a mild and environmentally friendly method was used to synthesize Ag nanoparticles (Ag NPs) on functionalized PDA-graphene nanosheets (PDA-GNS) with uniform and high dispersion. First, a uniform layer of PDA was coated on graphene oxide (GO) by polymerizing dopamine (DA) at room temperature. During the process GO was reduced by the DA. The PDA layer on the surface of GNS can be used as a nanoscale guide to form uniform Ag NPs on the surface of PDA-GNS. The obtained Ag-PDA-GNS hybrid materials are characterized by atomic force microscopy, transmission electron microscopy, UV-vis spectroscopy, Raman spectroscopy, X-ray photo-electron spectroscopy, X-ray diffraction, and thermal gravimetric analysis. The resultant Ag-PDA-GNS hybrid materials exhibited strong antibacterial properties to both Gram-negative and Gram-positive bacteria due to the synergistic effect of GNS and Ag NPs. Electronic supplementary information (ESI) available. See DOI: 10.1039/c2nr32092d
Late medical therapy of patent ductus arteriosus using intravenous paracetamol.
EL-Khuffash, Afif; James, Adam T; Cleary, Aoife; Semberova, Jana; Franklin, Orla; Miletin, Jan
2015-05-01
To investigate the effect of late treatment with intravenous paracetamol on patent ductus arteriosus (PDA) closure prior to possible PDA ligation. A retrospective review of infants with a haemodynamically significant PDA, considered for PDA ligation and treated with intravenous paracetamol prior to possible ligation. Thirty six infants with a median gestation of 26.1 weeks received paracetamol at a median age of 27 days. Paracetamol was associated with immediate closure in nine (25%) infants. There was no response to paracetamol treatment in four (11%) infants who subsequently underwent a PDA ligation. In 23 (64%) infants, the PDA constricted and all but one of this group demonstrated complete PDA closure prior to discharge. There may be a role for intravenous paracetamol in late closure of infants with a significant PDA to avoid ligation. The use of paracetamol for late treatment of PDA should be systematically evaluated. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
The impact of a personal digital assistant (PDA) case log in a medical student clerkship.
Ho, Kendall; Lauscher, Helen Novak; Broudo, Marc; Jarvis-Selinger, Sandra; Fraser, Joan; Hewes, Deborah; Scott, Ian
2009-10-01
Medical education literature emphasizes that reflection and self-audit are pivotal steps in learning and that personal digital assistants (PDAs) have potential as decision support tools. The purpose was to examine the efficacy of PDA-based resources and patient-encounter logging systems among 3rd-year medical clerks during pediatrics rotations. Students in rotations were assigned to control (using paper-based logs and references) or intervention groups (using PDA-based logs and resources). Students completed pre- and postrotation Paediatrics Competency Surveys, participated in focus groups, and were compared on year-end examination grades. Use of PDA logs far outweighed that of paper logs (1,020 PDA logs and 87 paper logs). PDA logs were ranked significantly higher in enhancing learning and reflection than paper logs (t = 2.52, p < .01). PDA logs also facilitated specific learning experiences. PDA-based patient-encounter logs appear to be effective case documentation and reflection tools. The difference in number of logs between control and intervention groups demonstrates the utility of the PDA for "point-of-care" patient logging.
Performance Analysis of IIUM Wireless Campus Network
NASA Astrophysics Data System (ADS)
Abd Latif, Suhaimi; Masud, Mosharrof H.; Anwar, Farhat
2013-12-01
International Islamic University Malaysia (IIUM) is one of the leading universities in the world in terms of quality of education that has been achieved due to providing numerous facilities including wireless services to every enrolled student. The quality of this wireless service is controlled and monitored by Information Technology Division (ITD), an ISO standardized organization under the university. This paper aims to investigate the constraints of wireless campus network of IIUM. It evaluates the performance of the IIUM wireless campus network in terms of delay, throughput and jitter. QualNet 5.2 simulator tool has employed to measure these performances of IIUM wireless campus network. The observation from the simulation result could be one of the influencing factors in improving wireless services for ITD and further improvement.
Ahmed, Ruhi; Baseman, Harold; Ferreira, Jorge; Genova, Thomas; Harclerode, William; Hartman, Jeffery; Kim, Samuel; Londeree, Nanette; Long, Michael; Miele, William; Ramjit, Timothy; Raschiatore, Marlene; Tomonto, Charles
2008-01-01
In July 2006 the Parenteral Drug Association's Risk Management Task Force for Aseptic Processes, conducted an electronic survey of PDA members to determine current industry practices regarding implementation of Quality Risk Management in their organizations. This electronic survey was open and publicly available via the PDA website and targeted professionals in our industry who are involved in initiating, implementing, or reviewing risk management programs or decisions in their organizations. One hundred twenty-nine members participated and their demographics are presented in the sidebar "Correspondents Profile". Among the major findings are: *The "Aseptic Processing/Filling" operation is the functional area identified as having the greatest need for risk assessment and quality risk management. *The most widely used methodology in industry to identify risk is Failure Mode and Effects Analysis (FMEA). This tool was most widely applied in assessing change control and for adverse event, complaint, or failure investigations. *Despite the fact that personnel training was identified as the strategy most used for controlling/minimizing risk, the largest contributors to sterility failure in operations are still "Personnel". *Most companies still rely on "Manufacturing Controls" to mitigate risk and deemed the utilization of Process Analytical Technology (PAT) least important in this aspect. *A majority of correspondents verified that they did not periodically assess their risk management programs. *A majority of the correspondents desired to see case studies or examples of risk analysis implementation (as applicable to aseptic processing) in future PDA technical reports on risk management.
Mansano, Raul K.; Godoy, Eduardo P.; Porto, Arthur J. V.
2014-01-01
Recent advances in wireless networking technology and the proliferation of industrial wireless sensors have led to an increasing interest in using wireless networks for closed loop control. The main advantages of Wireless Networked Control Systems (WNCSs) are the reconfigurability, easy commissioning and the possibility of installation in places where cabling is impossible. Despite these advantages, there are two main problems which must be considered for practical implementations of WNCSs. One problem is the sampling period constraint of industrial wireless sensors. This problem is related to the energy cost of the wireless transmission, since the power supply is limited, which precludes the use of these sensors in several closed-loop controls. The other technological concern in WNCS is the energy efficiency of the devices. As the sensors are powered by batteries, the lowest possible consumption is required to extend battery lifetime. As a result, there is a compromise between the sensor sampling period, the sensor battery lifetime and the required control performance for the WNCS. This paper develops a model-based soft sensor to overcome these problems and enable practical implementations of WNCSs. The goal of the soft sensor is generating virtual data allowing an actuation on the process faster than the maximum sampling period available for the wireless sensor. Experimental results have shown the soft sensor is a solution to the sampling period constraint problem of wireless sensors in control applications, enabling the application of industrial wireless sensors in WNCSs. Additionally, our results demonstrated the soft sensor potential for implementing energy efficient WNCS through the battery saving of industrial wireless sensors. PMID:25529208
NASA Astrophysics Data System (ADS)
Hayami, Hajime; Takehara, Hiroaki; Nagata, Kengo; Haruta, Makito; Noda, Toshihiko; Sasagawa, Kiyotaka; Tokuda, Takashi; Ohta, Jun
2016-04-01
Intra body communication technology allows the fabrication of compact implantable biomedical sensors compared with RF wireless technology. In this paper, we report the fabrication of an implantable image sensor of 625 µm width and 830 µm length and the demonstration of wireless image-data transmission through a brain tissue of a living mouse. The sensor was designed to transmit output signals of pixel values by pulse width modulation (PWM). The PWM signals from the sensor transmitted through a brain tissue were detected by a receiver electrode. Wireless data transmission of a two-dimensional image was successfully demonstrated in a living mouse brain. The technique reported here is expected to provide useful methods of data transmission using micro sized implantable biomedical sensors.
Final Scientific Report - Wireless and Sensing Solutions Advancing Industrial Efficiency
DOE Office of Scientific and Technical Information (OSTI.GOV)
Budampati, Rama; McBrady, Adam; Nusseibeh, Fouad
2009-09-28
The project team's goal for the Wireless and Sensing Solution Advancing Industrial Efficiency award (DE-FC36-04GO14002) was to develop, demonstrate, and test a number of leading edge technologies that could enable the emergence of wireless sensor and sampling systems for the industrial market space. This effort combined initiatives in advanced sensor development, configurable sampling and deployment platforms, and robust wireless communications to address critical obstacles in enabling enhanced industrial efficiency.
Development and application of a modified wireless tracer for disaster prevention
NASA Astrophysics Data System (ADS)
Chung Yang, Han; Su, Chih Chiang
2016-04-01
Typhoon-induced flooding causes water overflow in a river channel, which results in general and bridge scour and soil erosion, thus leading to bridge failure, debris flow and landslide collapse. Therefore, dynamic measurement technology should be developed to assess scour in channels and landslide as a disaster-prevention measure against bridge failure and debris flow. This paper presents a wireless tracer that enables monitoring general scour in river channels and soil erosion in hillsides. The wireless tracer comprises a wireless high-power radio modem, various electronic components, and a self-designed printed circuit board that are all combined with a 9-V battery pack and an auto switch. The entire device is sealed in a jar by silicon. After it was modified, the wireless tracer underwent the following tests for practical applications: power continuation and durability, water penetration, and signal transmission during floating. A regression correlation between the wireless tracer's transmission signal and distance was also established. This device can be embedded at any location where scouring is monitored, and, in contrast to its counterparts that detect scour depth by identifying and analyzing received signals, it enables real-time observation of the scouring process. In summary, the wireless tracer developed in this study provides a dynamic technology for real-time monitoring of scouring (or erosion) and forecasting of landslide hazards. Keywords: wireless tracer; scour; real-time monitoring; landslide hazard.
Thompson, Elizabeth J; Greenberg, Rachel G; Kumar, Karan; Laughon, Matthew; Smith, P Brian; Clark, Reese H; Crowell, Andromeda; Shaw, Layla; Harrison, Louis; Scales, Gabrielle; Bell, Nicole; Hornik, Christoph P
2018-05-08
To evaluate the association between furosemide exposure and patent ductus arteriosus (PDA) in a large, contemporary cohort of hospitalized infants with very low birth weight (VLBW). Using the Pediatrix Medical Group Clinical Data Warehouse, we identified all inborn infants of VLBW <37 weeks of gestation discharged from the neonatal intensive care unit after the first postnatal week from 2011 to 2015. We defined PDA as any medical (ibuprofen or indomethacin) or surgical PDA therapy. We collected data up to the day of PDA treatment or postnatal day 18 for infants not diagnosed with PDA. We performed multivariable logistic regression to evaluate the association between PDA and exposure to furosemide. We included 43 576 infants from 337 neonatal intensive care units, of whom 6675 (15%) underwent PDA treatment. Infants with PDA were more premature and more often exposed to mechanical ventilation and inotropes. Furosemide was prescribed to 4055 (9%) infants. On multivariable regression, exposure to furosemide was associated with decreased odds of PDA treatment (OR 0.72; 95% CI 0.65-0.79). Increasing percentage of days with furosemide exposure was not associated with PDA treatment (OR 1.01; 95% CI 0.97-1.06). Furosemide exposure was not associated with increased odds of PDA treatment in hospitalized infants of VLBW. Further studies are needed to characterize the efficacy and safety of furosemide in premature infants. Copyright © 2018 Elsevier Inc. All rights reserved.
Pulmonary artery dissection in eight dogs with patent ductus arteriosus.
Scansen, Brian A; Simpson, Elaine M; López-Alvarez, Jordi; Thomas, William P; Bright, Janice M; Eason, Bryan D; Rush, John E; Dukes-McEwan, Joanna; Green, Henry W; Cunningham, Suzanne M; Visser, Lance C; Kent, Agnieszka M; Schober, Karsten E
2015-06-01
To describe a series of dogs with pulmonary artery dissection and patent ductus arteriosus (PDA). Eight dogs. Retrospective case series. Pulmonary artery dissection was diagnosed in 8 dogs, 3 were Weimaraners. Four dogs presented in left-sided congestive heart failure, 4 presented for murmur evaluation and without clinical signs, and 1 presented in right-sided congestive heart failure. In 7 dogs the dissection was first documented concurrent with a diagnosis of uncorrected PDA. In the other dog, with pulmonary valve stenosis and PDA, the dissection was observed on autopsy examination 17 months after balloon pulmonary valvuloplasty and ductal closure. Median age at presentation for the 7 dogs with antemortem diagnosis of pulmonary artery dissection was 3.5 years (range, 1.5-4 years). Three dogs had the PDA surgically ligated, 2 dogs did not undergo PDA closure, 1 dog failed transcatheter occlusion of the PDA with subsequent surgical ligation, 1 dog underwent successful transcatheter device occlusion of the PDA, and 1 dog had the PDA closed by transcatheter coil delivery 17 months prior to the diagnosis of pulmonary artery dissection. The 2 dogs that did not have the PDA closed died 1 and 3 years after diagnosis due to heart failure. Pulmonary artery dissection is a potential complication of PDA in dogs, the Weimaraner breed may be at increased risk, presentation is often in mature dogs, and closure of the PDA can be performed and appears to improve outcome. Copyright © 2014 Elsevier B.V. All rights reserved.
Boghossian, Nansi S; Do, Barbara T; Bell, Edward F; Dagle, John M; Brumbaugh, Jane E; Stoll, Barbara J; Vohr, Betty R; Das, Abhik; Shankaran, Seetha; Sanchez, Pablo J; Wyckoff, Myra H; Bethany Ball, M
2017-10-01
Optimal management of the patent ductus arteriosus (PDA) in preterm infants remains controversial. Therefore, studies identifying infants who are most likely to benefit from PDA treatment are needed. We sought to examine if significant intrauterine growth restriction, defined by birth weight z-score, reduces the efficacy of PDA closure with indomethacin or ibuprofen and thereby increases the need for surgical closure of PDA after pharmacologic treatment. We studied infants 23-28weeks' gestation born 2006-2013 at NICHD Neonatal Research Network centers. We examined the responses to PDA treatment with indomethacin and/or ibuprofen and whether the PDA was subsequently closed surgically. Logistic regression generated adjusted odds ratios (ORs) for the associations between the z-score groups (<-2, -2 to -0.5, and >-0.5) and PDA surgery following pharmacologic treatment. 5606 infants were diagnosed with PDA; 3587 (64.0%) received indomethacin or ibuprofen or both, and 909 (25.3%) underwent PDA surgery. Mothers of infants with PDA non-closure were less likely to have hypertension (19% vs. 28%). Infants with non-closure were more likely to be female (53% vs. 49%), have lower gestational age and birth weight and to develop sepsis (42% vs. 31%). Compared to infants with z-score>-0.5, PDA surgery was increased among infants with z-score -2 to -0.5 (OR=1.23; 95% CI 1.02-1.47) but not among infants with z-score<-2. Infants with birth weight z-score -2 to -0.5 are more likely than normally grown infants to require PDA surgery following pharmacologic treatment. Copyright © 2017 Elsevier B.V. All rights reserved.
Kim, Joon Sik
2012-01-01
Background and Objectives Patent ductus arteriosus (PDA) is a significant cause of morbidity and mortality in preterm infants. Measurement of plasma B-type natriuretic peptide (BNP) has been reported to be a useful bedside screening tool for the presence of hemodynamically significant PDA (hsPDA) in neonates. This study was conducted to investigate the usefulness of a BNP assay as a biochemical marker for the diagnosis of hsPDA and predictive biomarker of the response to indomethacin in preterm infants. Subjects and Methods Preterm infants born at <37 weeks' gestational age were prospectively enrolled within 24 hours of birth. Plasma BNP levels were measured on days 1, 4, and 7. Significant PDA was diagnosed by large ductal flow with left to right shunt on color Doppler echocardiography, along with clinical features of PDA. Following that, hsPDA was treated with indomethacin. Results A total of 28 preterm infants were prospectively enrolled in this study. Seven infants with PDA had higher on day 4 plasma BNP values (median 654.68 pg/mL; range 428.29-1280.00) compared to the control group (median 124.52 pg/mL; range 37.21-290.49). The area under the receiver operator characteristic curve for the detection of hsPDA was high: 0.998 (95% confidence interval: 0.995-1.002). The cutoff of BNP concentration for the diagnosis of hsPDA was determined to be 412 pg/mL (sensitivity: 100%; specificity: 95%). Conclusion B-type natriuretic peptide can be a useful biomarker for the screening and diagnosis of PDA in preterm infants. Serial BNP measurements are valuable for assessing the clinical course and indomethacin responsiveness of PDA. PMID:22493614
Yang, Chuan-Zhong; Lee, Jiun
2008-05-01
The incidence of patent ductus arteriosus (PDA) is high in extremely low birth weight (ELBW) infants. Indomethacin has been widely used in the prophylaxis and treatment of hemodynamically significant PDA. This retrospective study was undertaken to identify factors such as birth weight, gestational age, gender, fetal growth retardation, ductal size, timing of the first dose of indomethacin and side effects of indomethacin, which may affect the successful closure of the PDA with indomethacin in ELBW infants. A cohort of 139 ELBW infants who had received indomethacin treatment for PDA during a consecutive period of more than three years (September 2000 to December 2003) was retrospectively analyzed. Administration of indomethacin was associated with closure of PDA in 108 (77.7%) of 139 ELBW infants, and only 19.4% of infants required surgical ligation of the ductus eventually. There was no significant relationship between closure of PDA with gestational age, gender, fetal growth retardation, and ductal size. A higher birth weight and early use of indomethacin after birth could significantly increase the closure rate of PDA (P<0.05). Side effects of indomethacin such as transient oliguria and hyponatremia during indomethacin therapy did not affect PDA closure. Indomethacin is effective for the treatment of PDA in ELBW infants. A higher rate of ductal closure is related to the increase of birth weight. PDA closure with indomethacin is age-related, and early administration of indomethacin could increase PDA closure and reduce the incidence of hyponatremia. There is no significant difference in major morbidities such as bronchopulmonary dysplasia (BPD), intraventricular hemorrhage (IVH), necrotizing enterocolitis (NEC), and retinopathy of prematurity (ROP) after early treatment. Early screening for hemodynamically significant PDA in ELBW infants and early treatment with indomethacin are recommended.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-01
... centers.\\4\\ \\4\\ The vendors supporting wireless transmission of CME data will install equipment on... wireless connectivity and obtain the lower latency transmission of data from third parties and NASDAQ that... Proposed Rule Change 1. Purpose Wireless technology has been in existence for many years, used primarily by...
Wireless Instrumentation Systems for Flight Testing at NASA AFRC
NASA Technical Reports Server (NTRS)
Hang, Richard
2017-01-01
NASA Armstrong Flight Research Center is revolutionizing its traditional wired instrumentation systems with wireless technologies. This effort faces many technical challenges, such as spectrum compliance, time synchronization, power distribution and airworthiness. This presentation summarizes NASA AFRC's flight test capabilities with current conventional instrumentation methodology and highlights the technical challenges of wireless systems used for flight test research applications.
NREL, EasyMile Collaboration to Usher in New Wave of Autonomous Vehicle R&D
technology such as wireless charging, connected and managed charging, and advanced energy storage. EasyMile International Airport. The NREL collaboration will explore opportunities for how wireless charging could enable wireless charging are a natural fit with autonomous and connected vehicles. We're excited this opportunity
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-07
..., including the use of automated collection techniques or other forms of information technology, and (e) ways... Stations (Including Wireless Microphones). Form No.: N/A. Type of Review: Revision of a currently approved... wireless microphones and provide them a home in the core TV spectrum, where many wireless microphones are...
Invisible Bridges: Wireless Technology Links Minds over Space and Time
ERIC Educational Resources Information Center
Lambert, Lori
2004-01-01
Eight years after Chief Sitting Bull, prophetic chief of the Great Sioux Nation, was assassinated in 1890, Guglielmo Marconi transmitted the first wireless telegraph signals across the Atlantic to England. Although these two events seem unrelated, the names of these two men of vision are linked together today by Marconi's wireless invention. Data,…
Intelligent Control in Automation Based on Wireless Traffic Analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kurt Derr; Milos Manic
2007-09-01
Wireless technology is a central component of many factory automation infrastructures in both the commercial and government sectors, providing connectivity among various components in industrial realms (distributed sensors, machines, mobile process controllers). However wireless technologies provide more threats to computer security than wired environments. The advantageous features of Bluetooth technology resulted in Bluetooth units shipments climbing to five million per week at the end of 2005 [1, 2]. This is why the real-time interpretation and understanding of Bluetooth traffic behavior is critical in both maintaining the integrity of computer systems and increasing the efficient use of this technology in controlmore » type applications. Although neuro-fuzzy approaches have been applied to wireless 802.11 behavior analysis in the past, a significantly different Bluetooth protocol framework has not been extensively explored using this technology. This paper presents a new neurofuzzy traffic analysis algorithm of this still new territory of Bluetooth traffic. Further enhancements of this algorithm are presented along with the comparison against the traditional, numerical approach. Through test examples, interesting Bluetooth traffic behavior characteristics were captured, and the comparative elegance of this computationally inexpensive approach was demonstrated. This analysis can be used to provide directions for future development and use of this prevailing technology in various control type applications, as well as making the use of it more secure.« less
Intelligent Control in Automation Based on Wireless Traffic Analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kurt Derr; Milos Manic
Wireless technology is a central component of many factory automation infrastructures in both the commercial and government sectors, providing connectivity among various components in industrial realms (distributed sensors, machines, mobile process controllers). However wireless technologies provide more threats to computer security than wired environments. The advantageous features of Bluetooth technology resulted in Bluetooth units shipments climbing to five million per week at the end of 2005 [1, 2]. This is why the real-time interpretation and understanding of Bluetooth traffic behavior is critical in both maintaining the integrity of computer systems and increasing the efficient use of this technology in controlmore » type applications. Although neuro-fuzzy approaches have been applied to wireless 802.11 behavior analysis in the past, a significantly different Bluetooth protocol framework has not been extensively explored using this technology. This paper presents a new neurofuzzy traffic analysis algorithm of this still new territory of Bluetooth traffic. Further enhancements of this algorithm are presented along with the comparison against the traditional, numerical approach. Through test examples, interesting Bluetooth traffic behavior characteristics were captured, and the comparative elegance of this computationally inexpensive approach was demonstrated. This analysis can be used to provide directions for future development and use of this prevailing technology in various control type applications, as well as making the use of it more secure.« less
Formative Assessment Design for PDA Integrated Ecology Observation
ERIC Educational Resources Information Center
Hung, Pi-Hsia; Lin, Yu-Fen; Hwang, Gwo-Jen
2010-01-01
Ubiquitous computing and mobile technologies provide a new perspective for designing innovative outdoor learning experiences. The purpose of this study is to propose a formative assessment design for integrating PDAs into ecology observations. Three learning activities were conducted in this study. An action research approach was applied to…
Wireless microwave acoustic sensor system for condition monitoring in power plant environments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pereira da Cunha, Mauricio
This project successfully demonstrated novel wireless microwave acoustic temperature and pressure sensors that can be embedded into equipment and structures located in fossil fuel power plant environments to monitor the condition of components such as steam headers, re-heat lines, water walls, burner tubes, and power turbines. The wireless microwave acoustic sensor technology researched and developed through a collaborative partnership between the University of Maine and Environetix Technologies Corporation can provide a revolutionary impact in the power industry since it is anticipated that the wireless sensors will deliver reliable real-time sensing information in harsh power plant conditions that involve temperatures upmore » to 1100oC and pressures up to 750 psi. The work involved the research and development of novel high temperature harsh environment thin film electrodes, piezoelectric smart microwave acoustic sensing elements, sensor encapsulation materials that were engineered to function over long times up to 1100oC, and a radio-frequency (RF) wireless interrogation electronics unit that are located both inside and outside the high temperature harsh environment. The UMaine / Environetix team have interacted with diverse power plant facilities, and identified as a testbed a local power generation facility, which burns municipal solid waste (MSW), the Penobscot Energy Recovery Company (PERC), Orrington, Maine. In this facility Environetix / UMaine successfully implemented and tested multiple wireless temperature sensor systems within the harsh-environment of the economizer chamber and at the boiler tubes, transferring the developed technology to the power plant environment to perform real-time sensor monitoring experiments under typical operating conditions, as initially targeted in the project. The wireless microwave acoustic sensor technology developed under this project for power plant applications offers several significant advantages including wireless, battery-free, maintenance-free operation, and operation in the harsh-environment of power plant equipment up to about 1100 oC. Their small size and configuration allows flexible sensor placement and embedding of multiple sensor arrays into a variety of components within power systems that can be interrogated by a single RF unit. The outcomes of this project and technological transfer respond to a DOE analysis need, which indicated that if one percent efficiency in coal burning is achieved, an additional 2 gigawatt-hours of energy per year is generated and the resulting coal cost savings is $300 million per year, also accompanied by a reduction of more than 10 million metric tons of CO2 per year emitted into the atmosphere. Therefore, the developed harsh environment wireless microwave acoustic sensor technology and the technological transfer achievements that resulted from the execution of this project have significant impact for power plant equipment and systems and are well-positioned to contribute to the cost reduction in power generation, the increase in power plant efficiency, the improvement in maintenance, the reduction in down-time, and the decrease in environmental pollution. The technology is also in a position to be extended to address other types of high-temperature harsh-environment power plant and energy sector sensing needs.« less
Optical wireless connected objects for healthcare.
Toumieux, Pascal; Chevalier, Ludovic; Sahuguède, Stéphanie; Julien-Vergonjanne, Anne
2015-10-01
In this Letter the authors explore the communication capabilities of optical wireless technology for a wearable device dedicated to healthcare application. In an indoor environment sensible to electromagnetic perturbations such as a hospital, the use of optical wireless links can permit reducing the amount of radio frequencies in the patient environment. Moreover, this technology presents the advantage to be secure, low-cost and easy to deploy. On the basis of commercially available components, a custom-made wearable device is presented, which allows optical wireless transmission of accelerometer data in the context of physical activity supervision of post-stroke patients in hospital. Considering patient mobility, the experimental performance is established in terms of packet loss as a function of the number of receivers fixed to the ceiling. The results permit to conclude that optical wireless links can be used to perform such mobile remote monitoring applications. Moreover, based on the measurements obtained with one receiver, it is possible to theoretically determine the performance according to the number of receivers to be deployed.
Cross-Layer Adaptive Feedback Scheduling of Wireless Control Systems
Xia, Feng; Ma, Longhua; Peng, Chen; Sun, Youxian; Dong, Jinxiang
2008-01-01
There is a trend towards using wireless technologies in networked control systems. However, the adverse properties of the radio channels make it difficult to design and implement control systems in wireless environments. To attack the uncertainty in available communication resources in wireless control systems closed over WLAN, a cross-layer adaptive feedback scheduling (CLAFS) scheme is developed, which takes advantage of the co-design of control and wireless communications. By exploiting cross-layer design, CLAFS adjusts the sampling periods of control systems at the application layer based on information about deadline miss ratio and transmission rate from the physical layer. Within the framework of feedback scheduling, the control performance is maximized through controlling the deadline miss ratio. Key design parameters of the feedback scheduler are adapted to dynamic changes in the channel condition. An event-driven invocation mechanism for the feedback scheduler is also developed. Simulation results show that the proposed approach is efficient in dealing with channel capacity variations and noise interference, thus providing an enabling technology for control over WLAN. PMID:27879934
Coexistence: Threat to the Performance of Heterogeneous Network
NASA Astrophysics Data System (ADS)
Sharma, Neetu; Kaur, Amanpreet
2010-11-01
Wireless technology is gaining broad acceptance as users opt for the freedom that only wireless network can provide. Well-accepted wireless communication technologies generally operate in frequency bands that are shared among several users, often using different RF schemes. This is true in particular for WiFi, Bluetooth, and more recently ZigBee. These all three operate in the unlicensed 2.4 GHz band, also known as ISM band, which has been key to the development of a competitive and innovative market for wireless embedded devices. But, as with any resource held in common, it is crucial that those technologies coexist peacefully to allow each user of the band to fulfill its communication goals. This has led to an increase in wireless devices intended for use in IEEE 802.11 wireless local area networks (WLANs) and wireless personal area networks (WPANs), both of which support operation in the crowded 2.4-GHz industrial, scientific and medical (ISM) band. Despite efforts made by standardization bodies to ensure smooth coexistence it may occur that communication technologies transmitting for instance at very different power levels interfere with each other. In particular, it has been pointed out that ZigBee could potentially experience interference from WiFi traffic given that while both protocols can transmit on the same channel, WiFi transmissions usually occur at much higher power level. In this work, we considered a heterogeneous network and analyzed the impact of coexistence between IEEE 802.15.4 and IEEE 802.11b. To evaluate the performance of this network, measurement and simulation study are conducted and developed in the QualNet Network simulator, version 5.0.Model is analyzed for different placement models or topologies such as Random. Grid & Uniform. Performance is analyzed on the basis of characteristics such as throughput, average jitter and average end to end delay. Here, the impact of varying different antenna gain & shadowing model for this heterogeneous network is considered for the purpose of analysis.
Zulqarnain, Arif; Younas, Muhammad; Waqar, Tariq; Beg, Ahsan; Asma, Touseef; Baig, Mirza Ahmad Raza
2016-01-01
Objectives: Comparison of effectiveness and cost of transcatheter occlusion of patent ductus arteriosus (PDA) with surgical ligation of PDA. Methods: This retrospective comparative study was conducted in the pediatric cardiology department of Ch. Pervaiz Elahi Institute of Cardiology Multan, Pakistan. Data of 250 patients who underwent patent ductus arteriosus (PDA) closure either surgical or trans-catheter closure using SHSMA Occluder having weight >5 kg from April 2012 to October 2015 were included in this study. SPSS version 20 was used for data analysis. Quantitative variables were compared using independent sample t-test. Chi-square test and fishers exact was used for qualitative variables. P-value <0.05 was considered statistically significant. Results: There were one hundred and twenty (120) patients who underwent transcatheter occlusion of PDA using SHSMA occluder (PDA Device Group) and one hundred and thirty (130) patients who underwent surgical ligation of PDA (Surgical Group). Incidence of residual shunting was two (1.5%) in surgical group and 0 (0.0%) in PDA Device group for one month follow up period. There were 4 (3.1%) major complications in surgical group. The rate of blood transfusions were high in surgical group (p-value 0.04). Hospital stay time was significantly less in PDA Device group (P-value <0.001). Total procedural cost was 110695+1054 Pakistani rupees in PDA Device group and 92414+3512 in surgical group (p-value <0.001). The cost of PDA device closure was 16.52% higher than the surgical ligation of PDA. There was no operative mortality. Conclusion: The transcatheter closure of PDA is an effective and less invasive method as compared to the surgical ligation. There is a lower rate of complications and the cost is not much high as compared to surgical PDA ligation. PMID:27648051
NASA Technical Reports Server (NTRS)
Hang, Richard
2015-01-01
The presentation will overview NASA Armstrong Flight Research Centers flight test capabilities, which can provide various means for flight testing of passive and active wireless sensor systems, also, it will address the needs of the wireless data acquisition solutions for the centers flight instrumentation issues such as additional weight caused by added instrumentation wire bundles, connectors, wire cables routing, moving components, etc., that the Passive Wireless Sensor Technology Workshop may help. The presentation shows the constraints and requirements that the wireless sensor systems will face in the flight test applications.
Analysis and Testing of Mobile Wireless Networks
NASA Technical Reports Server (NTRS)
Alena, Richard; Evenson, Darin; Rundquist, Victor; Clancy, Daniel (Technical Monitor)
2002-01-01
Wireless networks are being used to connect mobile computing elements in more applications as the technology matures. There are now many products (such as 802.11 and 802.11b) which ran in the ISM frequency band and comply with wireless network standards. They are being used increasingly to link mobile Intranet into Wired networks. Standard methods of analyzing and testing their performance and compatibility are needed to determine the limits of the technology. This paper presents analytical and experimental methods of determining network throughput, range and coverage, and interference sources. Both radio frequency (BE) domain and network domain analysis have been applied to determine wireless network throughput and range in the outdoor environment- Comparison of field test data taken under optimal conditions, with performance predicted from RF analysis, yielded quantitative results applicable to future designs. Layering multiple wireless network- sooners can increase performance. Wireless network components can be set to different radio frequency-hopping sequences or spreading functions, allowing more than one sooner to coexist. Therefore, we ran multiple 802.11-compliant systems concurrently in the same geographical area to determine interference effects and scalability, The results can be used to design of more robust networks which have multiple layers of wireless data communication paths and provide increased throughput overall.
Paksuniemi, M; Sorvoja, H; Alasaarela, E; Myllyla, R
2005-01-01
In the intensive care unit, or during anesthesia, patients are attached to monitors by cables. These cables obstruct nursing staff and hinder the patients from moving freely in the hospital. However, rapidly developing wireless technologies are expected to solve these problems. To this end, this study revealed problem areas in current patient monitoring and established the most important medical parameters to monitor. In addition, usable wireless techniques for short-range data transmission were explored and currently employed wireless applications in the hospital environment were studied. The most important parameters measured of the patient include blood pressures, electrocardiography, respiration rate, heart rate and temperature. Currently used wireless techniques in hospitals are based on the WMTS and WLAN standards. There are no viable solutions for short-range data transmission from patient sensors to patient monitors, but potentially usable techniques in the future are based on the WPAN standards. These techniques include Bluetooth, ZigBee and UWB. Other suitable techniques might be based on capacitive or inductive coupling. The establishing of wireless techniques depends on ensuring the reliability of data transmission, eliminating disturbance by other wireless devices, ensuring patient data security and patient safety, and lowering the power consumption and price.
Polydiacetylene chromism towards toxic chemical detection via molecular size-dependent selectivity
NASA Astrophysics Data System (ADS)
Seo, Donghwan
Polydiacetylene (PDA) is a pi-conjugated polymer that has unique optical properties. PDA changes color from blue to red when subjected to various stimuli such as mechanical stress, heat, photoirradiation, pH change, and binding of specific ligands. The steric effect induced by those stimuli on PDA headgroup has been investigated to understand the mechanism of PDA chromism and to apply those optical properties to the development of various sensors. In this work, pH chromism of PDA was examined in terms of the effects of the molecular size and acidity of acid analytes with the consideration of the molecular design aspect of diacetylene lipids. The pH level is an important parameter, since a low pH will produce a charge on the amine headgroup of PDA, but this does not necessarily result in PDA chromatic transition from 'blue phase' to 'red phase.' The molecular size of the counter anion was identified as another determinant condition to ensure the perturbation of the ene-yne conjugated backbone of PDA, which produces the chromatic transition. In the molecular design of the sensory diacetylene lipids, the alkyl spacer length between the amine as a receptor and the amide linker was found to strongly affect the degree of PDA chromatic transition. The longer alkyl spacer showed the less chromatic transition. The length of alkyl spacer seems to promote the flexibility of the molecule diminishing the extent of the transfer of the steric effect at PDA headgroup to the conjugated backbone. Finally, PDA chromism dependent on the molecular size of acid analytes was applied to develop the colorimetric detection of diethyl phosphate (DEP), a degraded nerve agent simulant. PDA liposome sensors successfully showed selective chromatic transition with fluorescent emission upon binding of DEP compared to other acid analytes. The molecular size and acidity of acid analytes, and alkyl spacer length have proven to be correlated with PDA chromism. These new findings provide further understanding of the mechanism of PDA chromism and the molecular design principle of diacetylene in fundamental studies and in the development of various applications.
ERIC Educational Resources Information Center
Shih, Ching-Hsiang
2013-01-01
The latest researches use software technology (OLDP, object location detection programs) to turn a commercial high-technology product, i.e. a battery-free wireless mouse, into a high performance/precise object location detector to detect whether or not an object has been placed in the designated location. The preferred environmental stimulation is…
PowerSat: A technology demonstration of a solar power satellite
NASA Technical Reports Server (NTRS)
Sigler, Douglas L. (Editor); Riedman, John; Duracinski, Jon; Edwards, Joe; Brown, Garry; Webb, Ron; Platzke, Mike; Yuan, Xiaolin; Rogers, Pete; Khan, Afsar
1994-01-01
PowerSat is a preliminary design strategy for microwave wireless power transfer of solar energy. Solar power satellites convert solar power into microwave energy and use wireless power transmission to transfer the power to the Earth's surface. The PowerSat project will show how new developments in inflatable technology can be used to deploy solar panels and phased array antennas.
A Survey on M2M Systems for mHealth: A Wireless Communications Perspective
Kartsakli, Elli; Lalos, Aris S.; Antonopoulos, Angelos; Tennina, Stefano; Di Renzo, Marco; Alonso, Luis; Verikoukis, Christos
2014-01-01
In the new era of connectivity, marked by the explosive number of wireless electronic devices and the need for smart and pervasive applications, Machine-to-Machine (M2M) communications are an emerging technology that enables the seamless device interconnection without the need of human interaction. The use of M2M technology can bring to life a wide range of mHealth applications, with considerable benefits for both patients and healthcare providers. Many technological challenges have to be met, however, to ensure the widespread adoption of mHealth solutions in the future. In this context, we aim to provide a comprehensive survey on M2M systems for mHealth applications from a wireless communication perspective. An end-to-end holistic approach is adopted, focusing on different communication aspects of the M2M architecture. Hence, we first provide a systematic review of Wireless Body Area Networks (WBANs), which constitute the enabling technology at the patient's side, and then discuss end-to-end solutions that involve the design and implementation of practical mHealth applications. We close the survey by identifying challenges and open research issues, thus paving the way for future research opportunities. PMID:25264958
NASA Astrophysics Data System (ADS)
Pleros, N.; Kalfas, G.; Mitsolidou, C.; Vagionas, C.; Tsiokos, D.; Miliou, A.
2017-01-01
Future broadband access networks in the 5G framework will need to be bilateral, exploiting both optical and wireless technologies. This paper deals with new approaches and synergies on radio-over-fiber (RoF) technologies and how those can be leveraged to seamlessly converge wireless technology for agility and mobility with passive optical networks (PON)-based backhauling. The proposed convergence paradigm is based upon a holistic network architecture mixing mm-wave wireless access with photonic integration, dynamic capacity allocation and network coding schemes to enable high bandwidth and low-latency fixed and 60GHz wireless personal area communications for gigabit rate per user, proposing and deploying on top a Medium-Transparent MAC (MT-MAC) protocol as a low-latency bandwidth allocation mechanism. We have evaluated alternative network topologies between the central office (CO) and the access point module (APM) for data rates up to 2.5 Gb/s and SC frequencies up to 60 GHz. Optical network coding is demonstrated for SCM-based signaling to enhance bandwidth utilization and facilitate optical-wireless convergence in 5G applications, reporting medium-transparent network coding directly at the physical layer between end-users communicating over a RoF infrastructure. Towards equipping the physical layer with the appropriate agility to support MT-MAC protocols, a monolithic InP-based Remote Antenna Unit optoelectronic PIC interface is shown that ensures control over the optical resource allocation assisting at the same time broadband wireless service. Finally, the MT-MAC protocol is analysed and simulation and analytical theoretical results are presented that are found to be in good agreement confirming latency values lower than 1msec for small- to mid-load conditions.
Utilisation of Wearable Computing for Space Programmes Test Activities Optimasation
NASA Astrophysics Data System (ADS)
Basso, V.; Lazzari, D.; Alemanni, M.
2004-08-01
New technologies are assuming a relevant importance in the Space business domain also in the Assembly Integration and Test (AIT) activities allowing process optimization and capability that were unthinkable only few years ago. This paper has the aim to describe Alenia Spazio (ALS) gained experience on the remote interaction techniques as a results of collaborations established both on European Communities (EC) initiatives, with Alenia Aeronautica (ALA) and Politecnico of Torino (POLITO). The H/W and S/W components performances increase and costs reduction due to the home computing massive utilization (especially demanded by the games business) together with the network technology possibility (offered by the web as well as the hi-speed links and the wireless communications) allow today to re-think the traditional AIT process activities in the light of the multimedia data exchange: graphical, voice video and by sure more in the future. Aerospace business confirm its innovation vocation which in the year '80 represents the cradle of the CAD systems and today is oriented to the 3D data visualization/ interaction technologies and remote visualisation/ interaction in collaborative way on a much more user friendly bases (i.e. not for specialists). Fig. 1 collects AIT extended scenario studied and adopted by ALS in these years. ALS experimented two possibilities of remote visualization/interaction: Portable [e.g. Fig.2 Personal Digital Assistant (PDA), Wearable] and walls (e.g.VR-Lab) screens as both 2D/3D visualisation and interaction devices which could support many types of traditional (mainly based on EGSE and PDM/CAD utilisation/reports) company internal AIT applications: 1. design review support 2. facility management 3. storage management 4. personnel training 5. integration sequences definition 6. assembly and test operations follow up 7. documentation review and external access to AIT activities for remote operations (e.g. tele-testing) EGSE Portable Clean room Walls PDM/CAD Tele-operations Product Control room External World
In vivo wireless biodiagnosis system for long-term bioactivity monitoring network
NASA Astrophysics Data System (ADS)
Chen, Chun-Kuang; Wu, Wen-Jong; Yu, Shih-An; Huang, Jhen-Gang; Lin, Yun-Han; Chen, Yih-Fan; Jin, Ming-Hui; Wen, Chih-Min; Kao, Cheng-Yan; Lin, Shi-Ming; Lu, Shey-Shi; Lin, Chii-Wann; Yen, Jia-Yush; Jaw, Fu-Shan; Chen, Chi-An; Liao, Fang-Jen; Chiu, Nan-Fu; Chien, Chia-Nan; Lee, Chih-Kung
2004-07-01
Attempts to develop a
A CMOS wireless biomolecular sensing system-on-chip based on polysilicon nanowire technology.
Huang, C-W; Huang, Y-J; Yen, P-W; Tsai, H-H; Liao, H-H; Juang, Y-Z; Lu, S-S; Lin, C-T
2013-11-21
As developments of modern societies, an on-field and personalized diagnosis has become important for disease prevention and proper treatment. To address this need, in this work, a polysilicon nanowire (poly-Si NW) based biosensor system-on-chip (bio-SSoC) is designed and fabricated by a 0.35 μm 2-Poly-4-Metal (2P4M) complementary metal-oxide-semiconductor (CMOS) process provided by a commercialized semiconductor foundry. Because of the advantages of CMOS system-on-chip (SoC) technologies, the poly-Si NW biosensor is integrated with a chopper differential-difference amplifier (DDA) based analog-front-end (AFE), a successive approximation analog-to-digital converter (SAR ADC), and a microcontroller to have better sensing capabilities than a traditional Si NW discrete measuring system. In addition, an on-off key (OOK) wireless transceiver is also integrated to form a wireless bio-SSoC technology. This is pioneering work to harness the momentum of CMOS integrated technology into emerging bio-diagnosis technologies. This integrated technology is experimentally examined to have a label-free and low-concentration biomolecular detection for both Hepatitis B Virus DNA (10 fM) and cardiac troponin I protein (3.2 pM). Based on this work, the implemented wireless bio-SSoC has demonstrated a good biomolecular sensing characteristic and a potential for low-cost and mobile applications. As a consequence, this developed technology can be a promising candidate for on-field and personalized applications in biomedical diagnosis.
Design of nodes for embedded and ultra low-power wireless sensor networks
NASA Astrophysics Data System (ADS)
Xu, Jun; You, Bo; Cui, Juan; Ma, Jing; Li, Xin
2008-10-01
Sensor network integrates sensor technology, MEMS (Micro-Electro-Mechanical system) technology, embedded computing, wireless communication technology and distributed information management technology. It is of great value to use it where human is quite difficult to reach. Power consumption and size are the most important consideration when nodes are designed for distributed WSN (wireless sensor networks). Consequently, it is of great importance to decrease the size of a node, reduce its power consumption and extend its life in network. WSN nodes have been designed using JN5121-Z01-M01 module produced by jennic company and IEEE 802.15.4/ZigBee technology. Its new features include support for CPU sleep modes and a long-term ultra low power sleep mode for the entire node. In low power configuration the node resembles existing small low power nodes. An embedded temperature sensor node has been developed to verify and explore our architecture. The experiment results indicate that the WSN has the characteristic of high reliability, good stability and ultra low power consumption.
NASA Astrophysics Data System (ADS)
Ruan, Mengnan; Yang, Dan; Guo, Wenli; Zhang, Liqun; Li, Shuxin; Shang, Yuwei; Wu, Yibo; Zhang, Min; Wang, Hao
2018-05-01
Surface functionalization of Al2O3 nano-particles by mussel-inspired poly(dopamine) (PDA) was developed to improve the dielectric properties, mechanical properties, and thermal conductivity properties of nitrile rubber (NBR) matrix. As strong adhesion of PDA to Al2O3 nano-particles and hydrogen bonds formed by the catechol groups of PDA and the polar acrylonitrile groups of NBR, the dispersion of Al2O3-PDA/NBR composites was improved and the interfacial force between Al2O3-PDA and NBR matrix was enhanced. Thus, the Al2O3-PDA/NBR composites exhibited higher dielectric constant, better mechanical properties, and larger thermal conductivity comparing with Al2O3/NBR composites at the same filler content. The largest thermal conductivity of Al2O3-PDA/NBR composite filled with 30 phr Al2O3-PDA was 0.21 W/m K, which was 122% times of pure NBR. In addition, the Al2O3-PDA/NBR composite filled with 30 phr Al2O3-PDA displayed a high tensile strength about 2.61 MPa, which was about 255% of pure NBR. This procedure is eco-friendly and easy handling, which provides a promising route to polymer composites in application of thermal conductivity field.
Effects of post-deposition annealing on sputtered SiO2/4H-SiC metal-oxide-semiconductor
NASA Astrophysics Data System (ADS)
Lee, Suhyeong; Kim, Young Seok; Kang, Hong Jeon; Kim, Hyunwoo; Ha, Min-Woo; Kim, Hyeong Joon
2018-01-01
Reactive sputtering followed by N2, NH3, O2, and NO post-deposition annealing (PDA) of SiO2 on 4H-SiC was investigated in this study. The results of ellipsometry, an etching test, and X-ray photoemission spectroscopy showed that N2 and NH3 PDA nitrified the SiO2. Devices using N2 and NH3 PDA exhibited a high gate leakage current and low breakdown field due to oxygen vacancies and incomplete oxynitride. SiO2/4H-SiC MOS capacitors were also fabricated and their electrical characteristics measured. The average breakdown fields of the devices using N2, NH3, O2, and NO PDA were 0.12, 0.17, 4.71 and 2.63 MV/cm, respectively. The shifts in the flat-band voltage after O2 and NO PDA were 0.95 and -2.56 V, respectively, compared with the theoretical value. The extracted effective oxide charge was -4.11 × 1011 cm-2 for O2 PDA and 1.11 × 1012 cm-2 for NO PDA. NO PDA for 2 h at 1200 °C shifted the capacitance-voltage curve in the negative direction. The oxygen containing PDA showed better electrical properties than non-oxygen PDA. The sputtering method described can be applied to 4H-SiC MOS fabrication.
Development of Wireless RFID Glove for Various Applications
NASA Astrophysics Data System (ADS)
Lee, Changwon; Kim, Minchul; Park, Jinwoo; Oh, Jeonghoon; Eom, Kihwan
Radio Frequency Identification is increasingly popular technology with many applications. The majority of applications of RFID are supply-chain management. In this paper, we proposed the development of wireless RFID Glove for various applications in real life. Proposed wireless RFID glove is composed of RFID reader of 13.56 MHz and RF wireless module. Proposed Gloves were applied to two applications. First is the interactive leaning and second is Meal aid system for blind people. The experimental results confirmed good performances.
Ning, Nanying; Ma, Qin; Liu, Suting; Tian, Ming; Zhang, Liqun; Nishi, Toshio
2015-05-27
In this study, we obtained dielectric elastomer composites with controllable dielectric and actuated properties by using a biomimetic method. We used dopamine (DA) to simultaneously coat the graphene oxide (GO) and partially reduce GO by self-polymerization of DA on GO. The poly(dopamine) (PDA) coated GO (GO-PDA) was assembled around rubber latex particles by hydrogen bonding interaction between carboxyl groups of carboxylated nitrile rubber (XNBR) and imino groups or phenolic hydroxyl groups of GO-PDA during latex compounding, forming a segregated GO-PDA network at a low percolation threshold. The results showed that the introduction of PDA on GO prevented the restack of GO in the matrix. The dielectric and actuated properties of the composites depend on the thickness of PDA shell. The dielectric loss and the elastic modulus decrease, and the breakdown strength increases with increasing the thickness of PDA shell. The maximum actuated strain increases from 1.7% for GO/XNBR composite to 4.4% for GO-PDA/XNBR composites with the PDA thickness of about 5.4 nm. The actuated strain at a low electric field (2 kV/mm) obviously increases from 0.2% for pure XNBR to 2.3% for GO-PDA/XNBR composite with the PDA thickness of 1.1 nm, much higher than that of other DEs reported in previous studies. Thus, we successfully obtained dielectric composites with low dielectric loss and improved breakdown strength and actuated strain at a low electric field, facilitating the wide application of dielectric elastomers.
Wireless roadside inspection phase II : final report : [technology brief].
DOT National Transportation Integrated Search
2014-04-01
The Federal Motor Carrier Safety Administration (FMCSA) Wireless Roadside Inspection (WRI) Program is demonstrating the feasibility and value of electronically assessing truck and motorcoach driver and vehicle safety. Electronic assessments (or WRIs)...
Performance Evaluation of High Speed Multicarrier System for Optical Wireless Communication
NASA Astrophysics Data System (ADS)
Mathur, Harshita; Deepa, T.; Bartalwar, Sophiya
2018-04-01
Optical wireless communication (OWC) in the infrared and visible range is quite impressive solution, especially where radio communication face challenges. Visible light communication (VLC) uses visible light over a range of 400 and 800 THz and is a subdivision of OWC technologies. With an increasing demand for use of wireless communications, wireless access via Wi-Fi is facing many challenges especially in terms of capacity, availability, security and efficiency. VLC uses intensity modulation and direct detection (IM/DD) techniques and hence they require the signals to certainly be real valued positive sequences. These constraints pose limitation on digital modulation techniques. These limitations result in spectrum-efficiency or power-efficiency losses. In this paper, we investigate an amplitude shift keying (ASK) based orthogonal frequency division multiplexing (OFDM) signal transmission scheme using LabVIEW for VLC technology.
Mobile access to the Internet: from personal bubble to satellites
NASA Astrophysics Data System (ADS)
Gerla, Mario
2001-10-01
Mobile, wireless access and networking has emerged in the last few years as one of the most important directions of Internet growth. The popularity of mobile, and, more generally, nomadic Internet access is due to many enabling factors including: (a) emergence of meaningful applications tailored to the individual on the move; (b) small form factor and long battery life; (c) efficient middleware designed to support mobility; and, (d) efficient wireless networking technologies. A key player in the mobile Internet access is the nomad, i.e. the individual equipped with various computing and I/O gadgets (cellular phone, earphones, GPS navigator, palm pilot, beeper, portable scanner, digital camera, etc.). These devices form his/her Personal Area Network or PAN or personal bubble. The connectivity within the bubble is wireless (using for example a low cost, low power wireless LAN such as Bluetooth). The bubble can expand and contract dynamically depending on needs. It may temporarily include sensors and actuators as the nomad walks into a new environment. In this paper, we identify the need for the interconnection of the PAN with other wireless networks in order to achieve costeffective mobile access to the Internet. We will overview some key networking technologies required to support the PAN (eg, Bluetooth). We will also discuss an emerging technology, Ad Hoc wireless networking which is the natural complement of the PAN in sparsely populated areas. Finally, we will identify the need for intelligent routers to assist the mobile user in the selection of the best Internet access strategy.
Survey on Monitoring and Quality Controlling of the Mobile Biosignal Delivery.
Pawar, Pravin A; Edla, Damodar R; Edoh, Thierry; Shinde, Vijay; van Beijnum, Bert-Jan
2017-10-31
A Mobile Patient Monitoring System (MPMS) acquires patient's biosignals and transmits them using wireless network connection to the decision-making module or healthcare professional for the assessment of patient's condition. A variety of wireless network technologies such as wireless personal area networks (e.g., Bluetooth), mobile ad-hoc networks (MANET), and infrastructure-based networks (e.g., WLAN and cellular networks) are in practice for biosignals delivery. The wireless network quality-of-service (QoS) requirements of biosignals delivery are mainly specified in terms of required bandwidth, acceptable delay, and tolerable error rate. An important research challenge in the MPMS is how to satisfy QoS requirements of biosignals delivery in the environment characterized by patient mobility, deployment of multiple wireless network technologies, and variable QoS characteristics of the wireless networks. QoS requirements are mainly application specific, while available QoS is largely dependent on QoS provided by wireless network in use. QoS provisioning refers to providing support for improving QoS experience of networked applications. In resource poor conditions, application adaptation may also be required to make maximum use of available wireless network QoS. This survey paper presents a survey of recent developments in the area of QoS provisioning for MPMS. In particular, our contributions are as follows: (1) overview of wireless networks and network QoS requirements of biosignals delivery; (2) survey of wireless networks' QoS performance evaluation for the transmission of biosignals; and (3) survey of QoS provisioning mechanisms for biosignals delivery in MPMS. We also propose integrating end-to-end QoS monitoring and QoS provisioning strategies in a mobile patient monitoring system infrastructure to support optimal delivery of biosignals to the healthcare professionals.
Powell, Laurie Ehlhardt; Glang, Ann; Ettel, Deborah; Todis, Bonnie; Sohlberg, McKay; Albin, Richard
2012-01-01
The goal of this study was to experimentally evaluate systematic instruction compared with trial-and-error learning (conventional instruction) applied to assistive technology for cognition (ATC), in a double blind, pretest-posttest, randomized controlled trial. Twenty-nine persons with moderate-severe cognitive impairments due to acquired brain injury (15 in systematic instruction group; 14 in conventional instruction) completed the study. Both groups received 12, 45-minute individual training sessions targeting selected skills on the Palm Tungsten E2 personal digital assistant (PDA). A criterion-based assessment of PDA skills was used to evaluate accuracy, fluency/efficiency, maintenance, and generalization of skills. There were no significant differences between groups at immediate posttest with regard to accuracy and fluency. However, significant differences emerged at 30-day follow-up in favor of systematic instruction. Furthermore, systematic instruction participants performed significantly better at immediate posttest generalizing trained PDA skills when interacting with people other than the instructor. These results demonstrate that systematic instruction applied to ATC results in better skill maintenance and generalization than trial-and-error learning for individuals with moderate-severe cognitive impairments due to acquired brain injury. Implications, study limitations, and directions for future research are discussed. PMID:22264146
Jun, Jaemoon; Oh, Jungkyun; Shin, Dong Hoon; Kim, Sung Gun; Lee, Jun Seop; Kim, Wooyoung; Jang, Jyongsik
2016-12-07
Due to rapid advances in technology which have contributed to the development of portable equipment, highly sensitive and selective sensor technology is in demand. In particular, many approaches to the modification of wireless sensor systems have been studied. Wireless systems have many advantages, including unobtrusive installation, high nodal densities, low cost, and potential commercial applications. In this study, we fabricated radio frequency identification (RFID)-based wireless sensor systems using carboxyl group functionalized polypyrrole (C-PPy) nanoparticles (NPs). The C-PPy NPs were synthesized via chemical oxidation copolymerization, and then their electrical and chemical properties were characterized by a variety of methods. The sensor system was composed of an RFID reader antenna and a sensor tag made from a commercially available ultrahigh frequency RFID tag coated with C-PPy NPs. The C-PPy NPs were covalently bonded to the tag to form a passive sensor. This type of sensor can be produced at a very low cost and exhibits ultrahigh sensitivity to ammonia, detecting concentrations as low as 0.1 ppm. These sensors operated wirelessly and maintained their sensing performance as they were deformed by bending and twisting. Due to their flexibility, these sensors may be used in wearable technologies for sensing gases.
Wireless technologies for closed-loop retinal prostheses.
Ng, David C; Bai, Shun; Yang, Jiawei; Tran, Nhan; Skafidas, Efstratios
2009-12-01
In this paper, we discuss various technologies needed to develop retinal prostheses with wireless power and data telemetry operation. In addition to the need to communicate with the implanted device, supply of power to the retinal prosthesis is especially difficult. This is because, in the implanted state, the device is not fixed in position due to constant motion of the eye. Furthermore, a retinal prosthesis incorporating a high density electrode array of more than 1000 electrodes is expected to consume approximately 45 mW of power and require 300 kbps of image and stimulation data. The front end of the wireless power and data transmission, the antenna, needs to be small compared to the size of the eye. Also, the wireless module is expected to operate in the reactive near-field region due to small separation between the transmit and receive antennas compared to their size and corresponding operating wavelength. An inductive link is studied as a means to transfer power and for data telemetry between the implant and external unit. In this work, the use of integrated circuit and microfabrication technologies for implementing inductive links is discussed. A closed-loop approach is taken to improve performance and reach optimum operation condition. Design and simulation data are presented as the basis for development of viable wireless module prototypes.
Wireless technologies for closed-loop retinal prostheses
NASA Astrophysics Data System (ADS)
Ng, David C.; Bai, Shun; Yang, Jiawei; Tran, Nhan; Skafidas, Efstratios
2009-12-01
In this paper, we discuss various technologies needed to develop retinal prostheses with wireless power and data telemetry operation. In addition to the need to communicate with the implanted device, supply of power to the retinal prosthesis is especially difficult. This is because, in the implanted state, the device is not fixed in position due to constant motion of the eye. Furthermore, a retinal prosthesis incorporating a high density electrode array of more than 1000 electrodes is expected to consume approximately 45 mW of power and require 300 kbps of image and stimulation data. The front end of the wireless power and data transmission, the antenna, needs to be small compared to the size of the eye. Also, the wireless module is expected to operate in the reactive near-field region due to small separation between the transmit and receive antennas compared to their size and corresponding operating wavelength. An inductive link is studied as a means to transfer power and for data telemetry between the implant and external unit. In this work, the use of integrated circuit and microfabrication technologies for implementing inductive links is discussed. A closed-loop approach is taken to improve performance and reach optimum operation condition. Design and simulation data are presented as the basis for development of viable wireless module prototypes.
3.5G based mobile remote monitoring system.
Bajracharya, Aman; Gale, Timothy J; Stack, Clive R; Turner, Paul
2008-01-01
Low bandwidth has long been a reason for the unsuitability of wireless internet in telemedicine. However with the advent of extended third generation wireless as an economically accessible high speed network, more opportunities are being created in this area of telemedicine. This paper explores the opportunity created by the latest wireless broadband technology for remote monitoring of patients in the home.
Cross Layered Multi-Meshed Tree Scheme for Cognitive Networks
2011-06-01
Meshed Tree Routing protocol wireless ad hoc networks ,” Second IEEE International Workshop on Enabling Technologies and Standards for Wireless Mesh ...and Sensor Networks , 2004 43. Chen G.; Stojmenovic I., “Clustering and routing in mobile wireless networks ,” Technical Report TR-99-05, SITE, June...Cross-layer optimization, intra-cluster routing , packet forwarding, inter-cluster routing , mesh network communications,
Next Generation RFID-Based Medical Service Management System Architecture in Wireless Sensor Network
NASA Astrophysics Data System (ADS)
Tolentino, Randy S.; Lee, Kijeong; Kim, Yong-Tae; Park, Gil-Cheol
Radio Frequency Identification (RFID) and Wireless Sensor Network (WSN) are two important wireless technologies that have wide variety of applications and provide unlimited future potentials most especially in healthcare systems. RFID is used to detect presence and location of objects while WSN is used to sense and monitor the environment. Integrating RFID with WSN not only provides identity and location of an object but also provides information regarding the condition of the object carrying the sensors enabled RFID tag. However, there isn't any flexible and robust communication infrastructure to integrate these devices into an emergency care setting. An efficient wireless communication substrate for medical devices that addresses ad hoc or fixed network formation, naming and discovery, transmission efficiency of data, data security and authentication, as well as filtration and aggregation of vital sign data need to be study and analyze. This paper proposed an efficient next generation architecture for RFID-based medical service management system in WSN that possesses the essential elements of each future medical application that are integrated with existing medical practices and technologies in real-time, remote monitoring, in giving medication, and patient status tracking assisted by embedded wearable wireless sensors which are integrated in wireless sensor network.
Synthesis and Characterization of Magnetic Carriers Based on Immobilized Enzyme
NASA Astrophysics Data System (ADS)
Li, F. H.; Tang, N.; Wang, Y. Q.; Zhang, L.; Du, W.; Xiang, J.; Cheng, P. G.
2018-05-01
Several new types of carriers and technologies have been implemented to improve traditional enzyme immobilization in industrial biotechnology. The magnetic immobilized enzyme is a kind of new method of enzyme immobilization developed in recent years. An external magnetic field can be used to control the motion mode and direction of immobilized enzyme, and to improve the catalytic efficiency of immobilized enzyme. In this paper, Fe3O4-CaCO3-PDA complex and CaCO3/Fe3O4 composite modified by PEI were prepared. The results show that the morphology of Fe3O4-CaCO3-PDA complex formation is irregular, while the morphology of CaCO3/Fe3O4 composite modified by PEI is regular and has a porous structure.
Passive Wireless SAW Sensors for IVHM
NASA Technical Reports Server (NTRS)
Wilson, William C.; Perey, Daniel F.; Atkinson, Gary M.; Barclay, Rebecca O.
2008-01-01
NASA aeronautical programs require integrated vehicle health monitoring (IVHM) to ensure the safety of the crew and the vehicles. Future IVHM sensors need to be small, light weight, inexpensive, and wireless. Surface acoustic wave (SAW) technology meets all of these constraints. In addition it operates in harsh environments and over wide temperature ranges, and it is inherently radiation hardened. This paper presents a survey of research opportunities for universities and industry to develop new sensors that address anticipated IVHM needs for aerospace vehicles. Potential applications of passive wireless SAW sensors from ground testing to high altitude aircraft operations are presented, along with some of the challenges and issues of the technology.
HERA: A New Platform for Embedding Agents in Heterogeneous Wireless Sensor Networks
NASA Astrophysics Data System (ADS)
Alonso, Ricardo S.; de Paz, Juan F.; García, Óscar; Gil, Óscar; González, Angélica
Ambient Intelligence (AmI) based systems require the development of innovative solutions that integrate distributed intelligent systems with context-aware technologies. In this sense, Multi-Agent Systems (MAS) and Wireless Sensor Networks (WSN) are two key technologies for developing distributed systems based on AmI scenarios. This paper presents the new HERA (Hardware-Embedded Reactive Agents) platform, that allows using dynamic and self-adaptable heterogeneous WSNs on which agents are directly embedded on the wireless nodes This approach facilitates the inclusion of context-aware capabilities in AmI systems to gather data from their surrounding environments, achieving a higher level of ubiquitous and pervasive computing.
Recent Advances in the Treatment of Preterm Newborn Infants with Patent Ductus Arteriosus.
Sallmon, Hannes; Koehne, Petra; Hansmann, Georg
2016-03-01
A patent ductus arteriosus (PDA) is associated with several adverse clinical conditions. Several strategies for PDA treatment exist, although data regarding the benefits of PDA treatment on outcomes are sparse. Moreover, the optimal treatment strategy for preterm neonates with PDA remains subject to debate. It is still unknown whether and when PDA treatment should be initiated and which approach (conservative, pharmacologic, or surgical) is best for individual patients (tailored therapies). This article reviews the current strategies for PDA treatment with a special focus on recent developments such as oral ibuprofen, high-dose regimens, and the use of paracetamol (oral, intravenous). Copyright © 2016 Elsevier Inc. All rights reserved.
Acute pain management efficiency improves with point-of-care handheld electronic billing system.
Fahy, Brenda G
2009-02-01
Technology advances continue to impact patient care and physician workflow. To enable more efficient performance of billing activities, a point-of-care (POC) handheld computer technology replaced a paper-based system on an acute pain management service. Using a handheld personal digital assistant (PDA) and software from MDeverywhere (MDe, MDeverywhere, Long Island, NY), we performed a 1-yr prospective observational study of an anesthesiology acute pain management service billings and collections. Seventeen anesthesiologists providing billable acute pain services were trained and entered their charges on a PDA. Twelve months of data, just before electronic implementation (pre-elec), were compared to a 12-m period after implementation (post-elec). The total charges were 4883 for 890 patients pre-elec and 5368 for 1128 patients post-elec. With adoption of handheld billing, the charge lag days decreased from 29.3 to 7.0 (P < 0.001). The days in accounts receivable trended downward from 59.9 to 51.1 (P = 0.031). The average number of charge lag days decreased significantly with month (P = 0.0002). The net collection rate increased from 37.4% pre-elec to 40.3% post-elec (P < 0.001). The return on investment was 1.18 fold (118%). Implementation of POC electronic billing using PDAs to replace a paper-based billing system improved the collection rate and decreased the number of charge lag days with a positive return on investment. The handheld PDA billing system provided POC support for physicians during their daily clinical (e.g., patient locations, rounding lists) and billing activities, improving workflow.
HWANG, HUI-JEONG; YOON, KYUNG LIM; SOHN, IL SUK
2016-01-01
The present study reported the case of a 60-year-old female with patent ductus arteriosus (PDA) and a bicuspid aortic valve, who presented with transient severe left ventricular (LV) dysfunction following percutaneous closure of PDA, as identified by speckle tracking analysis. Transient LV dysfunction following PDA closure has previously been reported; however, severe LV dysfunction is rare. In the present case, the combination of a large PDA size, large amount of shunting, LV remodeling and bicuspid aortic valve may have induced serious deterioration of LV function following PDA closure. Furthermore, speckle-tracking echocardiography may be useful in the estimation of functional alterations in the myocardium of the LV following PDA closure. The observations detailed in the present study may improve the understanding of the pathophysiology and myocardial patterns of transient left ventricular dysfunction following PDA closure in adult humans. PMID:26998021
Hwang, Hui-Jeong; Yoon, Kyung Lim; Sohn, Il Suk
2016-03-01
The present study reported the case of a 60-year-old female with patent ductus arteriosus (PDA) and a bicuspid aortic valve, who presented with transient severe left ventricular (LV) dysfunction following percutaneous closure of PDA, as identified by speckle tracking analysis. Transient LV dysfunction following PDA closure has previously been reported; however, severe LV dysfunction is rare. In the present case, the combination of a large PDA size, large amount of shunting, LV remodeling and bicuspid aortic valve may have induced serious deterioration of LV function following PDA closure. Furthermore, speckle-tracking echocardiography may be useful in the estimation of functional alterations in the myocardium of the LV following PDA closure. The observations detailed in the present study may improve the understanding of the pathophysiology and myocardial patterns of transient left ventricular dysfunction following PDA closure in adult humans.
NASA Astrophysics Data System (ADS)
Ninos, K.; Georgiadis, P.; Cavouras, D.; Nomicos, C.
2010-05-01
This study presents the design and development of a mobile wireless platform to be used for monitoring and analysis of seismic events and related electromagnetic (EM) signals, employing Personal Digital Assistants (PDAs). A prototype custom-developed application was deployed on a 3G enabled PDA that could connect to the FTP server of the Institute of Geodynamics of the National Observatory of Athens and receive and display EM signals at 4 receiver frequencies (3 KHz (E-W, N-S), 10 KHz (E-W, N-S), 41 MHz and 46 MHz). Signals may originate from any one of the 16 field-stations located around the Greek territory. Employing continuous recordings of EM signals gathered from January 2003 till December 2007, a Support Vector Machines (SVM)-based classification system was designed to distinguish EM precursor signals within noisy background. EM-signals corresponding to recordings preceding major seismic events (Ms≥5R) were segmented, by an experienced scientist, and five features (mean, variance, skewness, kurtosis, and a wavelet based feature), derived from the EM-signals were calculated. These features were used to train the SVM-based classification scheme. The performance of the system was evaluated by the exhaustive search and leave-one-out methods giving 87.2% overall classification accuracy, in correctly identifying EM precursor signals within noisy background employing all calculated features. Due to the insufficient processing power of the PDAs, this task was performed on a typical desktop computer. This optimal trained context of the SVM classifier was then integrated in the PDA based application rendering the platform capable to discriminate between EM precursor signals and noise. System's efficiency was evaluated by an expert who reviewed 1/ multiple EM-signals, up to 18 days prior to corresponding past seismic events, and 2/ the possible EM-activity of a specific region employing the trained SVM classifier. Additionally, the proposed architecture can form a base platform for a future integrated system that will incorporate services such as notifications for field station power failures, disruption of data flow, occurring SEs, and even other types of measurement and analysis processes such as the integration of a special analysis algorithm based on the ratio of short term to long term signal average.
ERIC Educational Resources Information Center
Blackbourn, J. M.; Fillingim, Jennifer G.; McCelland, Susan; Elrod, G. Franklin; Medley, Meagan B.; Kritsonis, Mary Alice; Ray, Jan
2008-01-01
This study examines the use of wireless laptop technology to support the application of problem-based learning (PBL) in a special education methods course. This field based course used a progressive disclosure process in weekly seminars to address issues posed in a case study. Eight scenarios, all related to the case, were presented to upper level…
"Fly-by-Wireless" : A Revolution in Aerospace Architectures for Instrumentation and Control
NASA Technical Reports Server (NTRS)
Studor, George F.
2007-01-01
The conference presentation provides background information on Fly-by-Wireless technologies as well as reasons for implementation, CANEUS project goals, cost of change for instrumentation, reliability, focus areas, conceptual Hybrid SHMS architecture for future space habitats, real world problems that the technology can solve, evolution of Micro-WIS systems, and a WLEIDS system overview and end-to-end system design.
Mobile eHealth interventions for obesity: a timely opportunity to leverage convergence trends.
Tufano, James T; Karras, Bryant T
2005-12-20
Obesity is often cited as the most prevalent chronic health condition and highest priority public health problem in the United States. There is a limited but growing body of evidence suggesting that mobile eHealth behavioral interventions, if properly designed, may be effective in promoting and sustaining successful weight loss and weight maintenance behavior changes. This paper reviews the current literature on the successes and failures of public health, provider-administered, and self-managed behavioral health interventions for weight loss. The prevailing theories of health behavior change are discussed from the perspective of how this knowledge can serve as an evidence base to inform the design of mobile eHealth weight loss interventions. Tailored informational interventions, which, in recent years, have proven to be the most effective form of conventional health behavior intervention for weight loss, are discussed. Lessons learned from the success of conventional tailored informational interventions and the early successes of desktop computer-assisted self-help weight management interventions are presented, as are design principles suggested by Social Cognitive Theory and the Social Marketing Model. Relevant computing and communications technology convergence trends are also discussed. The recent trends in rapid advancement, convergence, and public adoption of Web-enabled cellular telephone and wireless personal digital assistant (PDA) devices provide timely opportunities to deliver the mass customization capabilities, reach, and interactivity required for the development, administration, and adoption of effective population-level eHealth tailored informational interventions for obesity.
NASA Astrophysics Data System (ADS)
Namie, Hiromune; Morishita, Hisashi
The authors focused on the development of an indoor positioning system which is easy to use, portable and available for everyone. This system is capable of providing the correct position anywhere indoors, including onboard ships, and was invented in order to evaluate the availability of GPS indoors. Although the performance of GPS is superior outdoors, there has been considerable research regarding indoor GPS involving sensitive GPS, pseudolites (GPS pseudo satellite), RFID (Radio Frequency IDentification) tags, and wireless LAN .However, the positioning rate and the precision are not high enough for general use, which is the reason why these technologies have not yet spread to personal navigation systems. In this regard, the authors attempted to implement an indoor positioning system using cellular phones with built-in GPS and infrared light data communication functionality, which are widely used in Japan. GPS is becoming increasingly popular, where GPGGS sentences of the NMEA outputted from the GPS receiver provide spatiotemporal information including latitude, longitude, altitude, and time or ECEF xyz coordinates. As GPS applications grow rapidly, spatiotemporal data becomes key to the ubiquitous outdoor and indoor seamless positioning services at least for the entire area of Japan, as well as to becoming familiar with satellite positioning systems (e.g. GPS). Furthermore, the authors are also working on the idea of using PDAs (Personal Digital Assistants), as cellular phones with built-in GPS and PDA functionality are also becoming increasingly popular.
NASA Astrophysics Data System (ADS)
Palanisamy, Selvakumar; Thirumalraj, Balamurugan; Chen, Shen-Ming; Wang, Yi-Ting; Velusamy, Vijayalakshmi; Ramaraj, Sayee Kannan
2016-09-01
We report a novel and sensitive amperometric sensor for chlorpromazine (CPZ) based on reduced graphene oxide (RGO) and polydopamine (PDA) composite modified glassy carbon electrode. The RGO@PDA composite was prepared by electrochemical reduction of graphene oxide (GO) with PDA. The RGO@PDA composite modified electrode shows an excellent electro-oxidation behavior to CPZ when compared with other modified electrodes such as GO, RGO and GO@PDA. Amperometric i-t method was used for the determination of CPZ. Amperometry result shows that the RGO@PDA composite detects CPZ in a linear range from 0.03 to 967.6 μM. The sensor exhibits a low detection limit of 0.0018 μM with the analytical sensitivity of 3.63 ± 0.3 μAμM-1 cm-2. The RGO@PDA composite shows its high selectivity towards CPZ in the presence of potentially interfering drugs such as metronidazole, phenobarbital, chlorpheniramine maleate, pyridoxine and riboflavin. In addition, the fabricated RGO@PDA modified electrode showed an appropriate recovery towards CPZ in the pharmaceutical tablets.
Osma, Jorge; García-Palacios, Azucena; Botella, Cristina; Barrada, Juan Ramón
2014-05-01
No studies have been found that compared the psychopathology features, including personality disorders, of Panic Disorder (PD) and Panic Disorder with Agoraphobia (PDA), and a nonclinical sample with anxiety vulnerability. The total sample included 152 participants, 52 in the PD/PDA, 45 in the high anxiety sensitivity (AS) sample, and 55 in the nonclinical sample. The participants in PD/PDA sample were evaluated with the structured interview ADIS-IV. The Brief Symptom Inventory and the MCMI-III were used in all three samples. Statistically significant differences were found between the PD/PDA and the nonclinical sample in all MCMI-III scales except for antisocial and compulsive. No significant differences were found between PD/PDA and the sample with high scores in AS. Phobic Anxiety and Paranoid Ideation were the only scales where there were significant differences between the PD/PDA sample and the high AS sample. Our findings showed that people who scored high on AS, despite not having a diagnosis of PD/PDA, were similar in regard to psychopathology features and personality to individuals with PD/PDA.
To Close or Not to Close: The Very Small Patent Ductus Arteriosus
Fortescue, Elizabeth B.; Lock, James E.; Galvin, Teresa; McElhinney, Doff B.
2014-01-01
Patent ductus arteriosus (PDA) accounts for approximately 10% of all congenital heart diseases, with an incidence of at least 2–4 per 1000 term births. Closure of the large, hemodynamically significant PDA is established as the standard of care, and can be performed safely and effectively using either surgical or transcatheter methods. The appropriate management of the very small, hemodynamically insignificant PDA is less clear. Routine closure of such defects has been advocated to eliminate or reduce the risk of infective endocarditis (IE). However, the risk of IE in patients with a small PDA appears to be extremely low, and IE is treatable. Although closure of the small PDA is generally safe and technically successful, it is unknown whether this treatment truly improves the risk : benefit balance compared with observation. In this article, we review the published literature on the natural history and treatment outcomes in individuals with a PDA, the epidemiology and outcomes of IE, particularly in association with PDA, and the rationale and evidence for closure of the very small PDA. PMID:20653702
Liao, Qi-wei; Zhang, Wei-hua; Guang, Xue-feng; Lu, Yi-bing
2013-03-01
To explore the risk factors of patent ductus arteriosus (PDA) patients with thrombocytopenia after PDA interventional occlusion. Thrombocytopenia occurred in 14 out of 350 patients underwent PDA occlusion. Age, gender, body weight, PDA size, occluder size, mean pulmonary arterial pressure, the dose of heparin, the manufacturer of occluder, residual shunt after operation were analyzed. The recovery time of different grades of thrombocytopenia was observed. Multivariate logistic regression showed that the PDA size (OR = 2.238, P < 0.05), the dose of heparin (OR = 3.247, P < 0.05), residual shunt after operation (OR = 1.912, P < 0.01) were the independent risk factors of thrombocytopenia after PDA occlusion. The recovery time of mild thrombocytopenia was (7 ± 2) days without treatment. The recovery time of moderate thrombocytopenia was (12 ± 4) days with glucocorticoids treatment. The recovery time of severe thrombocytopenia was (21 ± 7) days with platelet transfusion. The occluder size, dose of heparin, residual shunt are the independent risk factors of thrombocytopenia after PDA interventional occlusion. Recover time of thrombocytopenia after PDA interventional occlusion is closely related to the severity of thrombocytopenia.
Wei, Yi; Gao, Li; Wang, Lu; Shi, Lin; Wei, Erdong; Zhou, Baotong; Zhou, Li; Ge, Bo
2017-11-01
We reported a simple polydopamine (PDA)-based surface modification method to prepare novel targeted doxorubicin-loaded mesoporous silica nanoparticles and peptide CSNRDARRC conjugation (DOX-loaded MSNs@PDA-PEP) for enhancing the therapeutic effects on bladder cancer. Drug-loaded NPs were characterized in terms of size, size distribution, zeta potential, transmission electron microscopy (TEM), Brunauer-Emmett-Teller (BET) surface area and drug loading content. In vitro drug release indicated that DOX-loaded MSNs@PDA and MSNs@PDA-PEP had similar release kinetic profiles of DOX. The PDA coating well controlled DOX release and was highly sensitive to pH value. Confocal laser scanning microscopy (CLSM) showed that drug-loaded MSNs could be internalized by human bladder cancer cell line HT-1376, and DOX-loaded MSNs@PDA-PEP had the highest cellular uptake efficiency due to ligand-receptor recognition. The antitumor effects of DOX-loaded nanoparticles were evaluated by the MTT assay in vitro and by a xenograft tumor model in vivo, demonstrating that targeted nanocarriers DOX-loaded MSNs@PDA-PEP were significantly superior to free DOX and DOX-loaded MSNs@PDA. The novel DOX-loaded MSNs@PDA-PEP, which specifically recognized HT-1376 cells, can be used as a potential targeted drug delivery system for bladder cancer therapy.
Hagadorn, James I; Brownell, Elizabeth A; Trzaski, Jennifer M; Johnson, Kendall R; Lainwala, Shabnam; Campbell, Brendan T; Herbst, Katherine W
2016-12-01
We examined recent trends and interhospital variation in use of indomethacin, ibuprofen, and surgical ligation for patent ductus arteriosus (PDA) in very-low-birth-weight (VLBW) infants. Included in this retrospective study of the Pediatric Hospital Information System database were 13,853 VLBW infants from 19 US children's hospitals, admitted at age < 3 d between 1 January 2005 and 31 December 2014. PDA management and in-hospital outcomes were examined for trends and variation. PDA was diagnosed in 5,719 (42%) VLBW infants. Cyclooxygenase inhibitors and/or ligation were used in 74% of infants with PDA overall, however studied hospitals varied greatly in PDA management. Odds of any cyclooxygenase inhibitor or surgical treatment for PDA decreased 11% per year during the study period. This was temporally associated with improved survival but also with increasing bronchopulmonary dysplasia, periventricular leukomalacia, retinopathy of prematurity, and acute renal failure in unadjusted analyses. There was no detectable correlation between hospital-specific changes in PDA management and hospital-specific changes in outcomes of preterm birth during the study period. Use of cyclooxygenase inhibitors and ligation for PDA in VLBW infants decreased over a 10-y period at the studied hospitals. Further evidence is needed to assess the impact of this change in PDA management.
Transcatheter closure of patent ductus arteriosus: past, present and future.
Baruteau, Alban-Elouen; Hascoët, Sébastien; Baruteau, Julien; Boudjemline, Younes; Lambert, Virginie; Angel, Claude-Yves; Belli, Emre; Petit, Jérôme; Pass, Robert
2014-02-01
This review aims to describe the past history, present techniques and future directions in transcatheter treatment of patent ductus arteriosus (PDA). Transcatheter PDA closure is the standard of care in most cases and PDA closure is indicated in any patient with signs of left ventricular volume overload due to a ductus. In cases of left-to-right PDA with severe pulmonary arterial hypertension, closure may be performed under specific conditions. The management of clinically silent or very tiny PDAs remains highly controversial. Techniques have evolved and the transcatheter approach to PDA closure is now feasible and safe with current devices. Coils and the Amplatzer Duct Occluder are used most frequently for PDA closure worldwide, with a high occlusion rate and few complications. Transcatheter PDA closure in preterm or low-bodyweight infants remains a highly challenging procedure and further device and catheter design development is indicated before transcatheter closure is the treatment of choice in this delicate patient population. The evolution of transcatheter PDA closure from just 40 years ago with 18F sheaths to device delivery via a 3F sheath is remarkable and it is anticipated that further improvements will result in better safety and efficacy of transcatheter PDA closure techniques. Copyright © 2014 Elsevier Masson SAS. All rights reserved.
Bluetooth data collection system for planning and arterial management.
DOT National Transportation Integrated Search
2014-08-01
This report presents the results of a research and development project of an implementable portable wireless traffic data collection system. Utilizing Bluetooth wireless technology as a platform, portable battery powered data collection units housed ...
Adapting Wireless Technology to Lighting Control and Environmental Sensing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dana Teasdale; Francis Rubinstein; Dave Watson
The high cost of retrofitting buildings with advanced lighting control systems is a barrier to adoption of this energy-saving technology. Wireless technology, however, offers a solution to mounting installation costs since it requires no additional wiring to implement. To demonstrate the feasibility of such a system, a prototype wirelessly-controlled advanced lighting system was designed and built. The system includes the following components: a wirelessly-controllable analog circuit module (ACM), a wirelessly-controllable electronic dimmable ballast, a T8 3-lamp fixture, an environmental multi-sensor, a current transducer, and control software. The ACM, dimmable ballast, multi-sensor, and current transducer were all integrated with SmartMesh{trademark} wirelessmore » mesh networking nodes, called motes, enabling wireless communication, sensor monitoring, and actuator control. Each mote-enabled device has a reliable communication path to the SmartMesh Manager, a single board computer that controls network functions and connects the wireless network to a PC running lighting control software. The ACM is capable of locally driving one or more standard 0-10 Volt electronic dimmable ballasts through relay control and a 0-10 Volt controllable output. The mote-integrated electronic dimmable ballast is designed to drive a standard 3-lamp T8 light fixture. The environmental multi-sensor measures occupancy, light level and temperature. The current transducer is used to measure the power consumed by the fixture. Control software was developed to implement advanced lighting algorithms, including daylight ramping, occupancy control, and demand response. Engineering prototypes of each component were fabricated and tested in a bench-scale system. Based on standard industry practices, a cost analysis was conducted. It is estimated that the installation cost of a wireless advanced lighting control system for a retrofit application is at least 30% lower than a comparable wired system for a typical 16,000 square-foot office building, with a payback period of less than 3 years.« less
Hamabe, L; Kim, S; Yoshiyuki, R; Fukayama, T; Nakata, T M; Fukushima, R; Tanaka, R
2015-01-01
Closure of PDA can be associated with echocardiographic changes including deterioration of LV systolic function. Although PDA is commonly encountered in dogs, few comprehensive reports of echocardiographic changes in dogs with PDA closure are available. To evaluate the short-term echocardiographic changes observed after PDA closure in dogs using strain analysis. Seventeen client-owned dogs with left-to-right PDA. Echocardiographic evaluations, including standard echocardiography and two-dimensional tissue tracking (2DTT), were performed before and within 3 days of PDA closure. Preclosure examination showed LV and left atrial dilatation indicating volume overload as a result of PDA. Closure of PDA resulted in significant reduction of LVIDd (<.0001) and LA/Ao (0.01) without change in LVIDs, suggestive of decreased preload. Postclosure LV systolic dysfunction was observed with significant decreased in FS (<.0001) and strain values (P = .0039 for radial strains, P = .0005 for circumferential strains). Additionally, significant LV dyssynchrony (P = .0162) was observed after closure of PDA. Closure of PDA resulted in decreased preload as a result of alleviation of LV volume overload, which in turn caused transient deterioration of LV systolic function. Additionally, this study demonstrated that strain analysis is load dependent. Therefore, care should be taken when interpreting strain measurements as an indicator of LV systolic function. Copyright © 2015 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of American College of Veterinary Internal Medicine.
El-Khuffash, A; Barry, D; Walsh, K; Davis, P G; Molloy, E J
2008-11-01
A patent ductus arteriosus (PDA) in preterm infants is associated with increased risk of intraventricular haemorrhage (IVH) and death. Cardiac troponin T (cTnT) and N-terminal-pro-B type natriuretic peptide (NTpBNP) are markers of cardiac function and can predict poor outcome in adults. To determine whether echocardiography and cTnT/NTpBNP levels at 48 h predict death before discharge or severe IVH in preterm infants with a PDA. Infants born <32 weeks' gestation or <1500 g underwent echocardiographic and cTnT/NTpBNP measurements at 12 and 48 h of life. Infants were divided according to their status at discharge: a closed PDA at 48 h, infants with a PDA at 48 h and IVH III/IV and/or death, and infants with a PDA at 48 h without IVH III/IV or death. Eighty infants with a median gestation of 28 weeks (IQR 26.1-29.5) and birth weight 1.06 kg (0.8-1.21) were included. At 48 h, infants with a PDA and IVH III/IV and/or death had significantly higher median cTnT/NTpBNP levels compared to infants with a PDA without IVH III/IV and/or death and those with spontaneous PDA closure (NTpBNP 9282, 5121 and 740 pmol/l, respectively, p = 0.008, and cTnT 0.66, 0.25 and 0.13 microg/l, respectively, p = 0.027). There were no differences in echocardiographic parameters of PDA size, left atrial to aortic ratio (LA:Ao), left and right ventricular outputs between the PDA groups. NTpBNP and cTnT in conjunction with echocardiography may provide a basis for trials of targeted medical treatment in infants with a PDA.
Chiang, Pei-Jung; Hsu, Jen-Fu; Tsai, Ming-Horng; Lien, Reyin; Chiang, Ming-Chou; Huang, Hsuan-Rong; Chiang, Chiao-Ching; Liang, Hwey-Fang; Chu, Shih-Ming
2012-10-01
Late-onset sepsis (LOS) in neonates with patent ductus arteriosus (PDA) may predispose them to more complicated hospital courses. The objective of this study was to determine the incidence, the distribution of pathogens, and the clinical features of LOS in neonates with PDA and analyze their outcomes. The medical records were reviewed retrospectively of infants with PDA and LOS who were hospitalized in NICUs of Chang Gung Children's Hospital between January 2003 and December 2009. The clinical features of these infants were compared with a group of gestational age and birth body weight-matched neonates with LOS during the same period. During this period, 224 neonates were found to have at least one event of blood-culture proven LOS and 79 (35.3%) were documented to have PDA. Although most LOS episodes (85/104, 81.7%) in neonates with PDA occurred after closure of PDA, neonates with PDA had a significantly higher rate of bronchopulmonary dysplasia (81.0% vs. 61.0%, p = 0.002) and a relatively higher rate of recurrent sepsis (25.3% vs. 15.2%, p = 0.079) than those without PDA. Longer durations of ventilator support and hospital stay were also noted in neonates with PDA as compared to those without (p = 0.001 and 0.005, respectively). In neonates with LOS, the presence of PDA, even though it is aggressively treated with indomethacin or surgical intervention, may still contribute to the complexity of hospitalization. Close monitoring and aggressive treatments are warranted in these neonates with PDA. Copyright © 2012. Published by Elsevier B.V.
Deep Space Habitat Wireless Smart Plug
NASA Technical Reports Server (NTRS)
Morgan, Joseph A.; Porter, Jay; Rojdev, Kristina; Carrejo, Daniel B.; Colozza, Anthony J.
2014-01-01
NASA has been interested in technology development for deep space exploration, and one avenue of developing these technologies is via the eXploration Habitat (X-Hab) Academic Innovation Challenge. In 2013, NASA's Deep Space Habitat (DSH) project was in need of sensors that could monitor the power consumption of various devices in the habitat with added capability to control the power to these devices for load shedding in emergency situations. Texas A&M University's Electronic Systems Engineering Technology Program (ESET) in conjunction with their Mobile Integrated Solutions Laboratory (MISL) accepted this challenge, and over the course of 2013, several undergraduate students in a Capstone design course developed five wireless DC Smart Plugs for NASA. The wireless DC Smart Plugs developed by Texas A&M in conjunction with NASA's Deep Space Habitat team is a first step in developing wireless instrumentation for future flight hardware. This paper will further discuss the X-Hab challenge and requirements set out by NASA, the detailed design and testing performed by Texas A&M, challenges faced by the team and lessons learned, and potential future work on this design.
Public health implications of wireless technologies.
Sage, Cindy; Carpenter, David O
2009-08-01
Global exposures to emerging wireless technologies from applications including mobile phones, cordless phones, DECT phones, WI-FI, WLAN, WiMAX, wireless internet, baby monitors, and others may present serious public health consequences. Evidence supporting a public health risk is documented in the BioInitiative Report. New, biologically based public exposure standards for chronic exposure to low-intensity exposures are warranted. Existing safety standards are obsolete because they are based solely on thermal effects from acute exposures. The rapidly expanding development of new wireless technologies and the long latency for the development of such serious diseases as brain cancers means that failure to take immediate action to reduce risks may result in an epidemic of potentially fatal diseases in the future. Regardless of whether or not the associations are causal, the strengths of the associations are sufficiently strong that in the opinion of the authors, taking action to reduce exposures is imperative, especially for the fetus and children. Such action is fully compatible with the precautionary principle, as enunciated by the Rio Declaration, the European Constitution Principle on Health (Section 3.1) and the European Union Treaties Article 174.
Chorioamnionitis and Patent Ductus Arteriosus: A Systematic Review and Meta-Analysis
Park, Hye Won; Choi, Yong-Sung; Kim, Kyo Sun; Kim, Soo-Nyung
2015-01-01
Background Chorioamnionitis has recently been reported as a risk factor for various neonatal diseases, including cerebral palsy, bronchopulmonary dysplasia, and necrotizing enterocolitis, but its effect on patent ductus arteriosus (PDA) is unclear. We performed a systematic review and meta-analysis to evaluate the effect of chorioamnionitis on PDA. Methods We searched PubMed, EMBASE, Cochrane Library, and KoreaMed databases using the terms: “intrauterine infection” or “maternal infection” or “antenatal infection” or “chorioamnionitis” or “placenta inflammation” or “placenta pathology” or “neonatal outcome” or “neonatal morbidity” or “PDA or patent ductus arteriosus” or “ductus arteriosus,” and “prematurity” or “very low birth weight infant.” Studies were included if they were randomized controlled trials, case–control studies, or cohort studies that included information relating to chorioamnionitis and PDA. Results Among 1,571 studies, a total of 23 studies (17,708 cases) were included in the meta-analysis to analyze the relationship between chorioamnionitis and PDA, except one study that only included PDA requiring surgical ligation. The association between chorioamnionitis and PDA was statistically significant (odds ratio [OR] 1.43; 95% confidence interval [CI] 1.19, 1.72; P < 0.0001). In subgroup analysis, clinical chorioamnionitis was not associated with PDA (OR 1.28; 95% CI 1.00, 1.64, 1.790; P = 0.05), whereas histologic chorioamnionitis (OR 1.54; 95% CI 1.10, 2.15; P = 0.01) and chorioamnionitis diagnosed from both clinical and histologic findings (OR 1.75; 95% CI 1.07, 2.86; P = 0.03) showed significant associations with PDA. Chorioamnionitis did not increase the risk of PDA requiring surgical ligation (OR 1.23; 95% CI 0.69, 2.17; P = 0.48), and antenatal steroid use reduced the risk of PDA (OR 0.62; 95% CI 0.42, 0.90; P = 0.01) after chorioamnionitis. Conclusions The results from this meta-analysis support an association between maternal chorioamnionitis and PDA in offspring. PMID:26375582
Prolonged persistent patent ductus arteriosus: potential perdurable anomalies in premature infants.
Saldeño, Y P; Favareto, V; Mirpuri, J
2012-12-01
Patent ductus arteriosus (PDA) is a common condition among preterm infants. Controversy exists regarding the risk-benefit ratio of early closure of PDAs by either medical or surgical treatments. On the other hand, potential morbidities associated with no or delayed closure has not been well studied. The objective of the study was to determine if there is an association of prolonged persistent PDA (PP-PDA) with various morbidities in infants ≤28 weeks or 1250 g. This matched case-control analysis includes preterm infants with a diagnosis of PDA over a period of 28 months in a single level III center in the USA. The predictive variable was the presence of a PP-PDA (PDA>3 weeks). Cases were infants with PP-PDA and controls were those with PDA but not PP-PDA (two controls for each case). Outcome variables included days on mechanical ventilation and with oxygen treatment, length of hospital stay, bronchopulmonary dysplasia (BPD), retinopathy of prematurity stage III-V (ROP) necrotizing enterocolitis grade II or more (NEC), delayed growth, direct hyperbilirubinemia >4 mg dl(-1) and osteopenia of prematurity. Data was obtained from database collected prospectively and from the review of clinical records when necessary. Statistics included ANOVA, Kaplan-Meier curves and χ (2). Significance was set at P<0.05. PP-PDA was associated with a significant increase in the number of days of mechanical ventilation, oxygen treatment and length of hospital stay, and in the rates of BPD (60% vs 4.5%), NEC (29% vs 5%), ROP (43% vs 5%), direct hyperbilirubinemia (41% vs 3%), osteopenia (44% vs 6%), parenteral nutrition for >40 days (70% vs 21%), tracheostomy during the hospitalization (15% vs 0%) and delayed growth (70% vs 21%), were also significantly higher in babies with PP-PDA. A prolonged exposure to PDA does not seem to be inconsequential for some infants and is associated with an increase prevalence of severe morbidities with potential long lasting effects.
Treatment of severe pulmonary hypertension in the setting of the large patent ductus arteriosus.
Niu, Mary C; Mallory, George B; Justino, Henri; Ruiz, Fadel E; Petit, Christopher J
2013-05-01
Treatment of the large patent ductus arteriosus (PDA) in the setting of pulmonary hypertension (PH) is challenging. Left patent, the large PDA can result in irreversible pulmonary vascular disease. Occlusion, however, may lead to right ventricular failure for certain patients with severe PH. Our center has adopted a staged management strategy using medical management, noninvasive imaging, and invasive cardiac catheterization to treat PH in the presence of a large PDA. This approach determines the safety of ductal closure but also leverages medical therapy to create an opportunity for safe PDA occlusion. We reviewed our experience with this approach. Patients with both severe PH and PDAs were studied. PH treatment history and hemodynamic data obtained during catheterizations were reviewed. Repeat catheterizations, echocardiograms, and clinical status at latest follow-up were also reviewed. Seven patients had both PH and large, unrestrictive PDAs. At baseline, all patients had near-systemic right ventricular pressures. Nine catheterizations were performed. Two patients underwent 2 catheterizations each due to poor initial response to balloon test occlusion. Six of 7 patients exhibited subsystemic pulmonary pressures during test occlusion and underwent successful PDA occlusion. One patient did not undergo PDA occlusion. In follow-up, 2 additional catheterizations were performed after successful PDA occlusion for subsequent hemodynamic assessment. At the latest follow-up, the 6 patients who underwent PDA occlusion are well, with continued improvement in PH. Five patients remain on PH treatment. A staged approach to PDA closure for patients with severe PH is an effective treatment paradigm. Aggressive treatment of PH creates a window of opportunity for PDA occlusion, echocardiography assists in identifying the timing for closure, and balloon test occlusion during cardiac catheterization is critical in determining safety of closure. By safely eliminating the large PDA, this treatment algorithm can halt the perilous combination of the large shunting from the PDA and PH in a population at high risk of morbidity and mortality.
Portable classroom leads to partnership.
Le Ber, Jeanne Marie; Lombardo, Nancy T; Weber, Alice; Bramble, John
2004-01-01
Library faculty participation on the School of Medicine Curriculum Steering Committee led to a unique opportunity to partner technology and teaching utilizing the library's portable wireless classroom. The pathology lab course master expressed a desire to revise the curriculum using patient cases and direct access to the Web and library resources. Since the pathology lab lacked computers, the library's portable wireless classroom provided a solution. Originally developed to provide maximum portability and flexibility, the wireless classroom consists of ten laptop computers configured with wireless cards and an access point. While the portable wireless classroom led to a partnership with the School of Medicine, there were additional benefits and positive consequences for the library.
Wireless Monitoring of Automobile Tires for Intelligent Tires
Matsuzaki, Ryosuke; Todoroki, Akira
2008-01-01
This review discusses key technologies of intelligent tires focusing on sensors and wireless data transmission. Intelligent automobile tires, which monitor their pressure, deformation, wheel loading, friction, or tread wear, are expected to improve the reliability of tires and tire control systems. However, in installing sensors in a tire, many problems have to be considered, such as compatibility of the sensors with tire rubber, wireless transmission, and battery installments. As regards sensing, this review discusses indirect methods using existing sensors, such as that for wheel speed, and direct methods, such as surface acoustic wave sensors and piezoelectric sensors. For wireless transmission, passive wireless methods and energy harvesting are also discussed. PMID:27873979
2014-01-01
Background Diabetes self-care by patients has been shown to assist in the reduction of disease severity and associated medical costs. We compared the effectiveness of two different diabetes self-care interventions on glycemic control in a racially/ethnically diverse population. We also explored whether reductions in glycated hemoglobin (HbA1c) will be more marked in minority persons. Methods We conducted an open-label randomized controlled trial of 376 patients with type 2 diabetes aged ≥18 years and whose last measured HbA1c was ≥7.5% (≥58 mmol/mol). Participants were randomized to: 1) a Chronic Disease Self-Management Program (CDSMP; n = 101); 2) a diabetes self-care software on a personal digital assistant (PDA; n = 81); 3) a combination of interventions (CDSMP + PDA; n = 99); or 4) usual care (control; n = 95). Enrollment occurred January 2009-June 2011 at seven regional clinics of a university-affiliated multi-specialty group practice. The primary outcome was change in HbA1c from randomization to 12 months. Data were analyzed using a multilevel statistical model. Results Average baseline HbA1c in the CDSMP, PDA, CDSMP + PDA, and control arms were 9.4%, 9.3%, 9.2%, and 9.2%, respectively. HbA1c reductions at 12 months for the groups averaged 1.1%, 0.7%, 1.1%, and 0.7%, respectively and did not differ significantly from baseline based on the model (P = .771). Besides the participants in the PDA group reporting eating more high-fat foods compared to their counterparts (P < .004), no other significant differences were observed in participants’ diabetes self-care activities. Exploratory sub-analysis did not reveal any marked reductions in HbA1c for minority persons but rather modest reductions for all racial/ethnic groups. Conclusions Although behavioral and technological interventions can result in some modest improvements in glycemic control, these interventions did not fare significantly better than usual care in achieving glycemic control. More research is needed to understand how these interventions can be most effective in clinical practice. The reduction in HbA1c levels found in our control group that received usual care also suggests that good routine care in an integrated healthcare system can lead to better glycemic control. Trial registration Clinicaltrials.gov Identifier: NCT01221090. PMID:24450992
Innovative Use of Smartphones for a Sound Resonance Tube Experiment
ERIC Educational Resources Information Center
Tho, Siew Wei; Yeung, Yau Yuen
2014-01-01
A Smartphone is not only a mobile device that is used for communication but is also integrated with a personal digital assistant (PDA) and other technological capabilities such as built-in acceleration, magnetic and light sensors, microphone, camera and Global Positioning System (GPS) unit. This handheld device has become very popular with the…
Academic Achievement Enhanced by Personal Digital Assistant Use
ERIC Educational Resources Information Center
Bick, Alexander
2005-01-01
Research during the past decade suggests that integrating computing technology in general, and mobile computers in particular, into the educational environment has positive effects. This is the first long-term study of high school Personal Digital Assistant use. It involved three-parts, 146 students during four years. Part one found that PDA use…
PDA Serials: Practical and Policy Issues for Librarians
ERIC Educational Resources Information Center
Good, Stephen
2007-01-01
Personal Digital Assistant serials are not just a subset of electronic serials from an acquisitions/collection development point of view because of their total dependence on patron-owned technology. Even if viewed as a "free" resource there are issues of expense and effort involved in gathering, classifying, and providing access and awareness of…
Portable Technology Comes of Age
ERIC Educational Resources Information Center
Wangemann, Paul; Lewis, Nina; Squires, David A.
2003-01-01
The PDA was originally conceived of as a portable handheld electronic device that provided a user with a tool to organize his or her life through easy access to a personal calendar, daily planner, and address book. Over the years, these devices have expanded to include many new functions, which have helped more applications in diverse fields. This…
Rethinking Mobile Telephony with the IMP
2011-01-01
in the telephony industry, and portions of it such as SS7 or SCTP signaling are packet-switched, deployed mobile telephony access infrastructure is...deployment of wireless LAN technology raises the question of how a mobile telephony system might instead be architected to use wireless LAN access ...and wireless access points has made universal Internet access increasingly convenient. There are clearly barriers to this vision of accessing a
Continuous, Wireless Monitoring of Sediment Flux within Streams on Military Installations
2013-10-17
2.2.1.3.2 Voltage Regulation ...................................................................................... 14 2.2.1.3.3 Mote and Data...components are: A. PCB board; B. Suspended sediment sensor; C. MDA300; D. Crossbow mote (not in the picture); E. Rain gauge; F. Two solenoid valves...wireless mote (MICA2, Crossbow Technology), a rechargeable battery, and a mounting structure. The exact configuration of the wireless sensor node
WiFi in Schools, Electromagnetic Fields and Cell Phones: Alberta Health Fact Sheet
ERIC Educational Resources Information Center
Alberta Education, 2012
2012-01-01
Wireless devices and the networks that support them are becoming more common in Alberta schools. WiFi is a wireless networking technology that allows computers and other devices to communicate over a wireless signal. Typically the signal is carried by radio waves over an area of up to 100 meters. Through the implementation of a WiFi network,…
ERIC Educational Resources Information Center
Huber, Joe; Gillan, Bud
2004-01-01
Just when thinking about the Internet and other tidal waves of technology have found their places in schools, along comes a brash new upstart called wirelessness. This discussion takes on more simple task of providing more useful information to schools in their quest for being wireless, including the use of COWS (computer on wheels) is related to…
Efficient security mechanisms for mHealth applications using wireless body sensor networks.
Sahoo, Prasan Kumar
2012-01-01
Recent technological advances in wireless communications and physiological sensing allow miniature, lightweight, ultra-low power, intelligent monitoring devices, which can be integrated into a Wireless Body Sensor Network (WBSN) for health monitoring. Physiological signals of humans such as heartbeats, temperature and pulse can be monitored from a distant location using tiny biomedical wireless sensors. Hence, it is highly essential to combine the ubiquitous computing with mobile health technology using wireless sensors and smart phones to monitor the well-being of chronic patients such as cardiac, Parkinson and epilepsy patients. Since physiological data of a patient are highly sensitive, maintaining its confidentiality is highly essential. Hence, security is a vital research issue in mobile health (mHealth) applications, especially if a patient has an embarrassing disease. In this paper a three tier security architecture for the mHealth application is proposed, in which light weight data confidentiality and authentication protocols are proposed to maintain the privacy of a patient. Moreover, considering the energy and hardware constraints of the wireless body sensors, low complexity data confidential and authentication schemes are designed. Performance evaluation of the proposed architecture shows that they can satisfy the energy and hardware limitations of the sensors and still can maintain the secure fabrics of the wireless body sensor networks. Besides, the proposed schemes can outperform in terms of energy consumption, memory usage and computation time over standard key establishment security scheme.
Competition in the domain of wireless networks security
NASA Astrophysics Data System (ADS)
Bednarczyk, Mariusz
2017-04-01
Wireless networks are very popular and have found wide spread usage amongst various segments, also in military environment. The deployment of wireless infrastructures allow to reduce the time it takes to install and dismantle communications networks. With wireless, users are more mobile and can easily get access to the network resources all the time. However, wireless technologies like WiFi or Bluetooth have security issues that hackers have extensively exploited over the years. In the paper several serious security flaws in wireless technologies are presented. Most of them enable to get access to the internal networks and easily carry out man-in-the-middle attacks. Very often, they are used to launch massive denial of service attacks that target the physical infrastructure as well as the RF spectrum. For instance, there are well known instances of Bluetooth connection spoofing in order to steal WiFi password stored in the mobile device. To raise the security awareness and protect wireless networks against an adversary attack, an analysis of attack methods and tools over time is presented in the article. The particular attention is paid to the severity, possible targets as well as the ability to persist in the context of protective measures. Results show that an adversary can take complete control of the victims' mobile device features if the users forget to use simple safety principles.
Efficient Security Mechanisms for mHealth Applications Using Wireless Body Sensor Networks
Sahoo, Prasan Kumar
2012-01-01
Recent technological advances in wireless communications and physiological sensing allow miniature, lightweight, ultra-low power, intelligent monitoring devices, which can be integrated into a Wireless Body Sensor Network (WBSN) for health monitoring. Physiological signals of humans such as heartbeats, temperature and pulse can be monitored from a distant location using tiny biomedical wireless sensors. Hence, it is highly essential to combine the ubiquitous computing with mobile health technology using wireless sensors and smart phones to monitor the well-being of chronic patients such as cardiac, Parkinson and epilepsy patients. Since physiological data of a patient are highly sensitive, maintaining its confidentiality is highly essential. Hence, security is a vital research issue in mobile health (mHealth) applications, especially if a patient has an embarrassing disease. In this paper a three tier security architecture for the mHealth application is proposed, in which light weight data confidentiality and authentication protocols are proposed to maintain the privacy of a patient. Moreover, considering the energy and hardware constraints of the wireless body sensors, low complexity data confidential and authentication schemes are designed. Performance evaluation of the proposed architecture shows that they can satisfy the energy and hardware limitations of the sensors and still can maintain the secure fabrics of the wireless body sensor networks. Besides, the proposed schemes can outperform in terms of energy consumption, memory usage and computation time over standard key establishment security scheme. PMID:23112734
Adapting Wireless Technology to Lighting Control and Environmental Sensing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dana Teasdale; Francis Rubinstein; David S. Watson
Although advanced lighting control systems offer significant energy savings, the high cost of retrofitting buildings with advanced lighting control systems is a barrier to adoption of this energy-saving technology. Wireless technology, however, offers a solution to mounting installation costs since it requires no additional wiring to implement. To demonstrate the feasibility of such a system, a prototype wirelessly-controlled advanced lighting system was designed and built. The system includes the following components: a wirelessly-controllable analog circuit module (ACM), a wirelessly-controllable electronic dimmable ballast, a T8 3-lamp fixture, an environmental multi-sensor, a current transducer, and control software. The ACM, dimmable ballast, multi-sensor,more » and current transducer were all integrated with SmartMesh{trademark} wireless mesh networking nodes, called motes, enabling wireless communication, sensor monitoring, and actuator control. Each mote-enabled device has a reliable communication path to the SmartMesh Manager, a single board computer that controls network functions and connects the wireless network to a PC running lighting control software. The ACM is capable of locally driving one or more standard 0-10 Volt electronic dimmable ballasts through relay control and a 0-10 Volt controllable output, in addition to 0-24 Volt and 0-10 Volt inputs. The mote-integrated electronic dimmable ballast is designed to drive a standard 3-lamp T8 light fixture. The environmental multisensor measures occupancy, light level and temperature. The current transducer is used to measure the power consumed by the fixture. Control software was developed to implement advanced lighting algorithms, including open and closed-loop daylight ramping, occupancy control, and demand response. Engineering prototypes of each component were fabricated and tested in a bench-scale system. Based on standard industry practices, a cost analysis was conducted. It is estimated that the installation cost of a wireless advanced lighting control system for a retrofit application is at least 20% lower than a comparable wired system for a typical 16,000 square-foot office building, with a payback period of less than 3 years. At 30% market penetration saturation, a cumulative 695 Billion kWh of energy could be saved through 2025, a cost savings of $52 Billion.« less
Kleiber, Catherine E
2017-01-01
A type 1 diabetic male reports multiple instances when his blood glucose was dramatically elevated by the presence of microwave radiation from wireless technology and plummeted when the radiation exposure ended. In one instance, his body temperature elevated in addition to his blood glucose. Both remained elevated for nearly 48 h after exposure with the effect gradually decreasing. Possible mechanisms for microwave radiation elevating blood glucose include effects on glucose transport proteins and ion channels, insulin conformational changes and oxidative stress. Temperature elevation may be caused by microwave radiation-triggered Ca 2+ efflux, a mechanism similar to malignant hyperthermia. The potential for radiation from wireless technology to cause serious biological effects has important implications and necessitates a reevaluation of its near-ubiquitous presence, especially in hospitals and medical facilities.
Sage, Cindy; Burgio, Ernesto
2018-01-01
Mobile phones and other wireless devices that produce electromagnetic fields (EMF) and pulsed radiofrequency radiation (RFR) are widely documented to cause potentially harmful health impacts that can be detrimental to young people. New epigenetic studies are profiled in this review to account for some neurodevelopmental and neurobehavioral changes due to exposure to wireless technologies. Symptoms of retarded memory, learning, cognition, attention, and behavioral problems have been reported in numerous studies and are similarly manifested in autism and attention deficit hyperactivity disorders, as a result of EMF and RFR exposures where both epigenetic drivers and genetic (DNA) damage are likely contributors. Technology benefits can be realized by adopting wired devices for education to avoid health risk and promote academic achievement. © 2017 The Authors. Child Development © 2017 Society for Research in Child Development, Inc.
A Wireless Biomedical Signal Interface System-on-Chip for Body Sensor Networks.
Lei Wang; Guang-Zhong Yang; Jin Huang; Jinyong Zhang; Li Yu; Zedong Nie; Cumming, D R S
2010-04-01
Recent years have seen the rapid development of biosensor technology, system-on-chip design, wireless technology. and ubiquitous computing. When assembled into an autonomous body sensor network (BSN), the technologies become powerful tools in well-being monitoring, medical diagnostics, and personal connectivity. In this paper, we describe the first demonstration of a fully customized mixed-signal silicon chip that has most of the attributes required for use in a wearable or implantable BSN. Our intellectual-property blocks include low-power analog sensor interface for temperature and pH, a data multiplexing and conversion module, a digital platform based around an 8-b microcontroller, data encoding for spread-spectrum wireless transmission, and a RF section requiring very few off-chip components. The chip has been fully evaluated and tested by connection to external sensors, and it satisfied typical system requirements.
Non-Ionizing Radiation From Wireless Technology| RadTown ...
2017-10-31
Cell phones emit radio frequency (RF) energy. The Federal Communications Commission (FCC) sets safety guidelines to limit RF exposure from wireless devices. Scientists continue to study the effects of long-term exposure to low levels of RF.
Low cost structural health monitoring of bridges using wireless SenSpot sensors.
DOT National Transportation Integrated Search
2012-05-01
Deterioration of highway bridges is a common, yet complex problem. To protect highway bridges, this : project combines a number of recent and emerging technologies microstructured sensing, ultra-lowpower : wireless communication, and advanced mic...
The Audacity of Fiber-Wireless (FiWi) Networks
NASA Astrophysics Data System (ADS)
Maier, Martin; Ghazisaidi, Navid; Reisslein, Martin
A plethora of enabling optical and wireless technologies have been emerging that can be used to build future-proof bimodal fiber-wireless (FiWi) broadband access networks. After overviewing key enabling radio-over-fiber (RoF) and radio-and-fiber (R&F) technologies and briefly surveying the state of the art of FiWi networks, we introduce an Ethernet-based access-metro FiWi network, called SuperMAN, that integrates next-generation WiFi and WiMAX networks with WDM-enhanced EPON and RPR networks. Throughout the paper we pay close attention to the technical challenges and opportunities of FiWi networks, but also elaborate on their societal benefits and potential to shift the current research focus from optical-wireless networking to the exploitation of personal and in-home computing facilities to create new unforeseen services and applications as we are about to enter the Petabyte age.
Integration of hybrid wireless networks in cloud services oriented enterprise information systems
NASA Astrophysics Data System (ADS)
Li, Shancang; Xu, Lida; Wang, Xinheng; Wang, Jue
2012-05-01
This article presents a hybrid wireless network integration scheme in cloud services-based enterprise information systems (EISs). With the emerging hybrid wireless networks and cloud computing technologies, it is necessary to develop a scheme that can seamlessly integrate these new technologies into existing EISs. By combining the hybrid wireless networks and computing in EIS, a new framework is proposed, which includes frontend layer, middle layer and backend layers connected to IP EISs. Based on a collaborative architecture, cloud services management framework and process diagram are presented. As a key feature, the proposed approach integrates access control functionalities within the hybrid framework that provide users with filtered views on available cloud services based on cloud service access requirements and user security credentials. In future work, we will implement the proposed framework over SwanMesh platform by integrating the UPnP standard into an enterprise information system.
Morak, Jürgen; Kumpusch, Hannes; Hayn, Dieter; Modre-Osprian, Robert; Schreier, Günter
2012-01-01
Utilization of information and communication technologies such as mobile phones and wireless sensor networks becomes more and more common in the field of telemonitoring for chronic diseases. Providing elderly people with a mobile-phone-based patient terminal requires a barrier-free design of the overall user interface including the setup of wireless communication links to sensor devices. To easily manage the connection between a mobile phone and wireless sensor devices, a concept based on the combination of Bluetooth and near-field communication technology has been developed. It allows us initiating communication between two devices just by bringing them close together for a few seconds without manually configuring the communication link. This concept has been piloted with a sensor device and evaluated in terms of usability and feasibility. Results indicate that this solution has the potential to simplify the handling of wireless sensor networks for people with limited technical skills.
Ubiquitous Computing for Remote Cardiac Patient Monitoring: A Survey
Kumar, Sunil; Kambhatla, Kashyap; Hu, Fei; Lifson, Mark; Xiao, Yang
2008-01-01
New wireless technologies, such as wireless LAN and sensor networks, for telecardiology purposes give new possibilities for monitoring vital parameters with wearable biomedical sensors, and give patients the freedom to be mobile and still be under continuous monitoring and thereby better quality of patient care. This paper will detail the architecture and quality-of-service (QoS) characteristics in integrated wireless telecardiology platforms. It will also discuss the current promising hardware/software platforms for wireless cardiac monitoring. The design methodology and challenges are provided for realistic implementation. PMID:18604301
Radio Relays Improve Wireless Products
NASA Technical Reports Server (NTRS)
2009-01-01
Signal Hill, California-based XCOM Wireless Inc. developed radio frequency micromachine (RF MEMS) relays with a Phase II Small Business Innovation Research (SBIR) contract through NASA?s Jet Propulsion Laboratory. In order to improve satellite communication systems, XCOM produced wireless RF MEMS relays and tunable capacitors that use metal-to-metal contact and have the potential to outperform most semiconductor technologies while using less power. These relays are used in high-frequency test equipment and instrumentation, where increased speed can mean significant cost savings. Applications now also include mainstream wireless applications and greatly improved tactical radios.
Ubiquitous computing for remote cardiac patient monitoring: a survey.
Kumar, Sunil; Kambhatla, Kashyap; Hu, Fei; Lifson, Mark; Xiao, Yang
2008-01-01
New wireless technologies, such as wireless LAN and sensor networks, for telecardiology purposes give new possibilities for monitoring vital parameters with wearable biomedical sensors, and give patients the freedom to be mobile and still be under continuous monitoring and thereby better quality of patient care. This paper will detail the architecture and quality-of-service (QoS) characteristics in integrated wireless telecardiology platforms. It will also discuss the current promising hardware/software platforms for wireless cardiac monitoring. The design methodology and challenges are provided for realistic implementation.
Thibodeau, Linda
2014-06-01
The purpose of this study was to compare the benefits of 3 types of remote microphone hearing assistance technology (HAT), adaptive digital broadband, adaptive frequency modulation (FM), and fixed FM, through objective and subjective measures of speech recognition in clinical and real-world settings. Participants included 11 adults, ages 16 to 78 years, with primarily moderate-to-severe bilateral hearing impairment (HI), who wore binaural behind-the-ear hearing aids; and 15 adults, ages 18 to 30 years, with normal hearing. Sentence recognition in quiet and in noise and subjective ratings were obtained in 3 conditions of wireless signal processing. Performance by the listeners with HI when using the adaptive digital technology was significantly better than that obtained with the FM technology, with the greatest benefits at the highest noise levels. The majority of listeners also preferred the digital technology when listening in a real-world noisy environment. The wireless technology allowed persons with HI to surpass persons with normal hearing in speech recognition in noise, with the greatest benefit occurring with adaptive digital technology. The use of adaptive digital technology combined with speechreading cues would allow persons with HI to engage in communication in environments that would have otherwise not been possible with traditional wireless technology.
Green survivability in Fiber-Wireless (FiWi) broadband access network
NASA Astrophysics Data System (ADS)
Liu, Yejun; Guo, Lei; Gong, Bo; Ma, Rui; Gong, Xiaoxue; Zhang, Lincong; Yang, Jiangzi
2012-03-01
Fiber-Wireless (FiWi) broadband access network is a promising "last mile" access technology, because it integrates wireless and optical access technologies in terms of their respective merits, such as high capacity and stable transmission from optical access technology, and easy deployment and flexibility from wireless access technology. Since FiWi is expected to carry a large amount of traffic, numerous traffic flows may be interrupted by the failure of network components. Thus, survivability in FiWi is a key issue aiming at reliable and robust service. However, the redundant deployment of backup resource required for survivability usually causes huge energy consumption, which aggravates the global warming and accelerates the incoming of energy crisis. Thus, the energy-saving issue should be considered when it comes to survivability design. In this paper, we focus on the green survivability in FiWi, which is an innovative concept and remains untouched in the previous works to our best knowledge. We first review and discuss some challenging issues about survivability and energy-saving in FiWi, and then we propose some instructive solutions for its green survivability design. Therefore, our work in this paper will provide the technical references and research motivations for the energy-efficient and survivable FiWi development in the future.
Data management using the personal digital assistant in an acute pain service.
Chan, S S; Chu, C P; Cheng, B C; Chen, P P
2004-02-01
Handheld personal digital assistants (PDA) are increasingly being used by physicians for a variety of information and data management purposes. We evaluated a PDA-based data management system for our acute pain service. A structured questionnaire survey was conducted to assess staff experience and attitude towards the paper system before the introduction of the PDA, and three months after introduction of the PDA system. We compared the time taken to conduct the acute pain round before and after the implementation of the PDA. The time saved in data management and the amount of paper saved were estimated. Data from 177 patients with a total of 635 acute pain follow-up visits were entered over a three-month period. User satisfaction, ease of access to drug reference and clinical guidelines were similar between the two systems. The respondents found that the PDA was easy to use but less so than the paper system (P = 0.007), in particular, when accessing a patient's cumulative data (P = 0.007). There was no missed follow-up or data entry with the use of PDA. The time taken to attend follow-up visits was similar for the two systems (Paper: 8.8 +/- 3.2 compared to PDA: 7.0 +/- 2.0 minutes, P = 0.151). The estimated annual amount of paper and time saved in data management was 650 sheets and 130 man-hours respectively. Our experience with the use of the PDA in APS was satisfactory. The PDA system can potentially reduce time and paper use and missed data entry and patient follow-up.
Leca, Julie; Martinez, Sébastien; Lac, Sophie; Nigri, Jérémy; Secq, Véronique; Rubis, Marion; Bressy, Christian; Lavaut, Marie-Noelle; Dusetti, Nelson; Loncle, Céline; Roques, Julie; Pietrasz, Daniel; Bousquet, Corinne; Garcia, Stéphane; Granjeaud, Samuel; Ouaissi, Mehdi; Bachet, Jean Baptiste; Iovanna, Juan L.; Zimmermann, Pascale; Vasseur, Sophie
2016-01-01
The intratumoral microenvironment, or stroma, is of major importance in the pathobiology of pancreatic ductal adenocarcinoma (PDA), and specific conditions in the stroma may promote increased cancer aggressiveness. We hypothesized that this heterogeneous and evolving compartment drastically influences tumor cell abilities, which in turn influences PDA aggressiveness through crosstalk that is mediated by extracellular vesicles (EVs). Here, we have analyzed the PDA proteomic stromal signature and identified a contribution of the annexin A6/LDL receptor-related protein 1/thrombospondin 1 (ANXA6/LRP1/TSP1) complex in tumor cell crosstalk. Formation of the ANXA6/LRP1/TSP1 complex was restricted to cancer-associated fibroblasts (CAFs) and required physiopathologic culture conditions that improved tumor cell survival and migration. Increased PDA aggressiveness was dependent on tumor cell–mediated uptake of CAF-derived ANXA6+ EVs carrying the ANXA6/LRP1/TSP1 complex. Depletion of ANXA6 in CAFs impaired complex formation and subsequently impaired PDA and metastasis occurrence, while injection of CAF-derived ANXA6+ EVs enhanced tumorigenesis. We found that the presence of ANXA6+ EVs in serum was restricted to PDA patients and represents a potential biomarker for PDA grade. These findings suggest that CAF–tumor cell crosstalk supported by ANXA6+ EVs is predictive of PDA aggressiveness, highlighting a therapeutic target and potential biomarker for PDA. PMID:27701147
[Risk factors for patent ductus arteriosus in early preterm infants: a case-control study].
Du, Jin-Feng; Liu, Tian-Tian; Wu, Hui
2016-01-01
To investigate the risk factors for the occurrence of patent ductus arteriosus (PDA) and to provide a clinical basis for reducing the occurrence of PDA in early preterm infants. A total of 136 early preterm infants (gestational age≤32 weeks) who were hospitalized between January 2013 and December 2014 and diagnosed with hemodynamicalhy significant PDA (hs-PDA) were enrolled as the case group. Based on the matched case-control principle, 136 early preterm infants without hs-PDA were selected among those who were hospitalized within the same period at a ratio of 1:1 and enrolled as the control group. The two groups were matched for sex and gestational age. The basic information of neonates and maternal conditions during the pregnancy and perinatal periods were collected. Logistic regression analysis was performed to identify the risk factors for the development of PDA. Univariate analysis showed that neonatal infectious diseases, neonatal respiratory distress syndrome, decreased platelet count within 24 hours after birth, and low birth weight were associated with the development of hs-PDA (P<0.05). Multivariate conditional logistic regression analysis revealed that neonatal infectious diseases (OR=2.368) and decreased platelet count within 24 hours after birth (OR=0.996) were independent risk factors for hs-PDA. Neonatal infectious diseases and decreased platelet count within 24 hours after birth increase the risk of hs-PDA in early preterm infants.
Does patent ductus arteriosus affect feed tolerance in preterm neonates?
Patole, S K; Kumaran, V; Travadi, J N; Brooks, J M; Doherty, D A
2007-01-01
Patent ductus arteriosus (PDA), especially PDA with sepsis, has been reported as a risk factor for feed intolerance in preterm neonates. In this study, the start to full feeds interval was found to be longest in preterm neonates (
Cu(II)-Doped Polydopamine-Coated Gold Nanorods for Tumor Theranostics.
Liu, Shuwei; Wang, Lu; Lin, Min; Wang, Dandan; Song, Ziqi; Li, Shuyao; Ge, Rui; Zhang, Xue; Liu, Yi; Li, Zhimin; Sun, Hongchen; Yang, Bai; Zhang, Hao
2017-12-27
Gold nanorods (AuNRs) are potentially useful in tumor theranostics, but the poor stability, high toxicity, and rapid removal by the immune system seriously limit their theranostic applications. In our study, we demonstrate the fabrication of Cu(II)-doped polydopamine-coated AuNR (AuNR@CuPDA), which significantly improves the potentials in tumor theranostics. Besides the improvement of physiological stability and biocompatibility, the PDA shell increases the photothermal performance and prolongs the blood circulation time of AuNRs. The half-life of AuNRs during blood circulation increases from 0.7 to 4.5 h after PDA coating, and the injected dose per gram of tumor tissue is 4.6% ID g -1 for AuNR@CuPDA. In addition to computer tomography imaging, the loading of Cu(II) in PDA shell endows AuNR@CuPDA with magnetic resonance imaging function. Cu(II) doped in PDA shell also exhibits chemotherapeutic behavior, and the tumor inhibitor rate is 31.2%. Further combining 808 nm laser-driven photothermal therapy, tumors were completely ablated, and no recurrence was observed. Liver and renal functions tests and histological analysis of major organs confirm that AuNR@CuPDA is in good safety.
Personal digital assistant use by nurse practitioners: a descriptive study.
Stroud, Sally D; Smith, Carol A; Erkel, Elizabeth A
2009-01-01
We sought to describe the prevalence and patterns of use of personal digital assistants (PDAs) among active nurse practitioners (NPs). A descriptive correlational survey was conducted among NPs in the United States (N = 126). Participants were randomly selected from members of the American Academy of Nurse Practitioners who had listed a practice site on their application. Sixty-four percent of participants used PDAs. A drug reference was reported to be the most useful and frequently installed application. A large majority of PDA users believed that PDA use supported clinical decision making (91%), promoted patient safety (89%), and increased productivity (75%). Sixty-two percent predicted that PDA use would change their practice within the next 5 years. As innovative PDA applications with potential to improve patient outcomes become increasingly available, handheld computer skills will be a fundamental practice competency. To prevent errors in clinical decision making with quick access to PDA reference materials, NPs must critically evaluate the legitimacy and worth of PDA software programs. There is a critical need to evaluate the effectiveness of PDA use in clinical settings and develop an evidence base to guide use of the PDA in solving clinical problems.
Palanisamy, Selvakumar; Thirumalraj, Balamurugan; Chen, Shen-Ming; Wang, Yi-Ting; Velusamy, Vijayalakshmi; Ramaraj, Sayee Kannan
2016-01-01
We report a novel and sensitive amperometric sensor for chlorpromazine (CPZ) based on reduced graphene oxide (RGO) and polydopamine (PDA) composite modified glassy carbon electrode. The RGO@PDA composite was prepared by electrochemical reduction of graphene oxide (GO) with PDA. The RGO@PDA composite modified electrode shows an excellent electro-oxidation behavior to CPZ when compared with other modified electrodes such as GO, RGO and GO@PDA. Amperometric i-t method was used for the determination of CPZ. Amperometry result shows that the RGO@PDA composite detects CPZ in a linear range from 0.03 to 967.6 μM. The sensor exhibits a low detection limit of 0.0018 μM with the analytical sensitivity of 3.63 ± 0.3 μAμM–1 cm–2. The RGO@PDA composite shows its high selectivity towards CPZ in the presence of potentially interfering drugs such as metronidazole, phenobarbital, chlorpheniramine maleate, pyridoxine and riboflavin. In addition, the fabricated RGO@PDA modified electrode showed an appropriate recovery towards CPZ in the pharmaceutical tablets. PMID:27650697
Preparation and antibacterial properties of Ag@polydopamine/graphene oxide sheet nanocomposite
NASA Astrophysics Data System (ADS)
Zhou, Hao; Liu, Yunfang; Chi, Weidong; Yu, Changyuan; Yu, Yingjie
2013-10-01
Immobilization of silver nanoparticles (Ag NPs) on poly-dopamine (PDA) functionalized graphene oxide sheets (GOSs) were carried out by an easy in situ reduction method. The PDA layer was coated on the surface of the GOSs via the self-polymerization of dopamine under atmosphere condition. The PDA layer not only works as the chemisorption and reduction sites for silver ions to form Ag NPs but also stabilizes them. High-resolution transmission electron microscopy observation shows that the average size of the Ag NPs anchored on the PDA/GOS composite is about 2.8 nm. The inhibition zone diameter of the Ag@PDA/GOS nanocomposite is about 23.7 mm, whereas said diameter of the Ag NPs is only 18.5 mm. The minimum bactericidal concentration of the Ag@PDA/GOS nanocomposite is about 25 μg/ml that is only half of said concentration of the Ag NPs. The Ag@PDA/GOS nanocomposite exhibits an excellent antibacterial property.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ling, Yang; Li, Weizhen; Wang, Baoyu
Carbon nanotubes (CNTs) functionalized by a nanothin poly(dopamine) (PDA) layer were produced by a one-pot, nondestructive approach, with direct polymerization of dopamine on the CNT surface. The thickness of the PDA layer can be well-controlled by the reaction time and the proportion of dopamine, and this thickness is found to be the key factor in controlling the dispersion of CNTs and the extent of the interfacial interactions between the CNT@PDA and epoxy resin. SEM results indicated that the dispersion of CNTs in epoxy was improved significantly by coating a nanothin PDA layer onto the CNT surface. In agreeme nt withmore » this finding, the CNTs functionalized with the thinnest PDA layer provided the best mechanical and thermal properties. This result confirmed that a thinner PDA layer could provide optimized interfacial interactions between the CNT@PDA and epoxy matrix and weaken the self-agglomeration of CNTs, which led to an improved effective stress and heat transfer between the CNTs and the polymer matrix.« less
Chung, Eun-Jae; Jun, Dae-Ryong; Kim, Dong-Wook; Han, Mi-Jung; Kwon, Tack-Kyun; Choi, Sung-Wook; Kwon, Seong Keun
2017-01-01
The use of injectable bulking agents is a feasible alternative procedure for conventional surgical therapy. In this study, poly(dimethylsiloxane) (PDMS) microspheres coated with polydopamine (PDA) were developed as a potential injection agent to prevent migration in vocal fold. Uniform PDMS microspheres are fabricated using a simple fluidic device and then coated with PDA. Cell attachment test reveals that the PDA-coated PDMS (PDA-PDMS) substrate favors cell adhesion and attachment. The injected PDA-PDMS microspheres persist without migration on reconstructed axial CT images, whereas, pristine PDMS locally migrates over a period of 12 weeks. The gross appearance of the implants retrieved at 4, 8, 12 and 34 weeks indicates that the PDA-PDMS group maintained their original position without significant migration until 34 weeks after injection. By contrast, there is diffuse local migration of the pristine PDMS group from 4 weeks after injection. The PDA-coated PDMS microspheres can potentially be used as easily injectable, non-absorbable filler without migration.
Kim, Dong-Wook; Han, Mi-Jung; Kwon, Tack-Kyun; Choi, Sung-Wook
2017-01-01
The use of injectable bulking agents is a feasible alternative procedure for conventional surgical therapy. In this study, poly(dimethylsiloxane) (PDMS) microspheres coated with polydopamine (PDA) were developed as a potential injection agent to prevent migration in vocal fold. Uniform PDMS microspheres are fabricated using a simple fluidic device and then coated with PDA. Cell attachment test reveals that the PDA-coated PDMS (PDA-PDMS) substrate favors cell adhesion and attachment. The injected PDA-PDMS microspheres persist without migration on reconstructed axial CT images, whereas, pristine PDMS locally migrates over a period of 12 weeks. The gross appearance of the implants retrieved at 4, 8, 12 and 34 weeks indicates that the PDA-PDMS group maintained their original position without significant migration until 34 weeks after injection. By contrast, there is diffuse local migration of the pristine PDMS group from 4 weeks after injection. The PDA-coated PDMS microspheres can potentially be used as easily injectable, non-absorbable filler without migration. PMID:29095854
NASA Astrophysics Data System (ADS)
Zheng, Yu; Lu, Shixiang; Xu, Wenguo; He, Ge; Cheng, Yuanyuan; Yu, Tianlong; Zhang, Yan
2018-02-01
A three dimensional composite electrode consisted of reduced graphene oxide (rGO), polydopamine (PDA) and nickel foam (NF) (rGO/PDA/NF) was fabricated by immersing NF into PDA aqueous solution and then graphene oxide (GO) suspension solution respectively, and followed by annealing treatment. During the procedure, GO was coated on NF with assistance of cohesive effect of the PDA middle film, and the reduction of GO and nitrogen doping occurred simultaneously while annealing. Through XRD analyzing, the composites GO/PDA and rGO/PDA treated in experiment are amorphous. The resulted rGO/PDA/NF composite electrode was directly applied as a supercapacitor electrode and showed excellent electrochemical performance, with a high specific capacitance of 566.9 F g-1 at 1 A g-1, the maximum energy density of 172.7 W h kg-1 and a power density of 27.2 kW kg-1 in 1 mol L-1 Na2SO4 electrolyte.
Coil occlusion of residual shunts after surgical closure of patent ductus arteriosus.
Fujii, Yoko; Keene, Bruce W; Mathews, Kyle G; Atkins, Clarke E; Defrancesco, Teresa C; Hardie, Elizabeth M; Wakao, Yoshito
2006-12-01
OBJECTIVE; To describe use of coil embolization to occlude residual flow through a patent ductus arteriosus (PDA) after incomplete surgical ligation. Clinical study. Dogs (n=4) with continuous murmur after surgical ligation of PDA. After PDA ligation, residual ductal flow through the PDA was visible on color-flow Doppler examination and left ventricular end-diastolic diameter remained increased. Coil embolization by an arterial approach was performed to achieve complete occlusion of the PDA. Embolization coils were delivered without complications and hemodynamically successful occlusion was achieved. Doppler-visible flow resolved in 2 dogs within 3 months after embolization. Left ventricular end-diastolic diameter indexed to body weight decreased in all dogs. Transcatheter coil embolization appears to be a safe and minimally invasive procedure for complete occlusion of residual PDA flow after incomplete surgical ligation. Transcatheter coil embolization should be considered for correction of hemodynamically significant residual shunts in dogs that have incomplete PDA occlusion after open surgical ligation.
Tran, Chung Duc; Ibrahim, Rosdiazli; Asirvadam, Vijanth Sagayan; Saad, Nordin; Sabo Miya, Hassan
2018-04-01
The emergence of wireless technologies such as WirelessHART and ISA100 Wireless for deployment at industrial process plants has urged the need for research and development in wireless control. This is in view of the fact that the recent application is mainly in monitoring domain due to lack of confidence in control aspect. WirelessHART has an edge over its counterpart as it is based on the successful Wired HART protocol with over 30 million devices as of 2009. Recent works on control have primarily focused on maintaining the traditional PID control structure which is proven not adequate for the wireless environment. In contrast, Internal Model Control (IMC), a promising technique for delay compensation, disturbance rejection and setpoint tracking has not been investigated in the context of WirelessHART. Therefore, this paper discusses the control design using IMC approach with a focus on wireless processes. The simulation and experimental results using real-time WirelessHART hardware-in-the-loop simulator (WH-HILS) indicate that the proposed approach is more robust to delay variation of the network than the PID. Copyright © 2017. Published by Elsevier Ltd.
An overview of wireless structural health monitoring for civil structures.
Lynch, Jerome Peter
2007-02-15
Wireless monitoring has emerged in recent years as a promising technology that could greatly impact the field of structural monitoring and infrastructure asset management. This paper is a summary of research efforts that have resulted in the design of numerous wireless sensing unit prototypes explicitly intended for implementation in civil structures. Wireless sensing units integrate wireless communications and mobile computing with sensors to deliver a relatively inexpensive sensor platform. A key design feature of wireless sensing units is the collocation of computational power and sensors; the tight integration of computing with a wireless sensing unit provides sensors with the opportunity to self-interrogate measurement data. In particular, there is strong interest in using wireless sensing units to build structural health monitoring systems that interrogate structural data for signs of damage. After the hardware and the software designs of wireless sensing units are completed, the Alamosa Canyon Bridge in New Mexico is utilized to validate their accuracy and reliability. To improve the ability of low-cost wireless sensing units to detect the onset of structural damage, the wireless sensing unit paradigm is extended to include the capability to command actuators and active sensors.
Pohjonen, Hanna; Ross, Peeter; Blickman, Johan G; Kamman, Richard
2007-01-01
Emerging technologies are transforming the workflows in healthcare enterprises. Computing grids and handheld mobile/wireless devices are providing clinicians with enterprise-wide access to all patient data and analysis tools on a pervasive basis. In this paper, emerging technologies are presented that provide computing grids and streaming-based access to image and data management functions, and system architectures that enable pervasive computing on a cost-effective basis. Finally, the implications of such technologies are investigated regarding the positive impacts on clinical workflows.
Larios, Diego F; Barbancho, Julio; Sevillano, José L; Rodríguez, Gustavo; Molina, Francisco J; Gasull, Virginia G; Mora-Merchan, Javier M; León, Carlos
2013-09-10
Wireless Sensor Networks (WSNs) are a technology that is becoming very popular for many applications, and environmental monitoring is one of its most important application areas. This technology solves the lack of flexibility of wired sensor installations and, at the same time, reduces the deployment costs. To demonstrate the advantages of WSN technology, for the last five years we have been deploying some prototypes in the Doñana Biological Reserve, which is an important protected area in Southern Spain. These prototypes not only evaluate the technology, but also solve some of the monitoring problems that have been raised by biologists working in Doñana. This paper presents a review of the work that has been developed during these five years. Here, we demonstrate the enormous potential of using machine learning in wireless sensor networks for environmental and animal monitoring because this approach increases the amount of useful information and reduces the effort that is required by biologists in an environmental monitoring task.
Degradations to microprocessor-based systems due to environmental stressors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Messman, P. A.; Peilai, Z.; Goodenow, D. A.
Recent studies indicate that EMI/RFI is the most significant environmental Stressor with potential for leading to digital systems degradation and failure. With digital I and C and wireless technology becoming standard in many industrial environments, nuclear power plant operators of current and future plants will or already have implemented these technologies seeking to leverage the economic benefits of such technology. With digital I and C systems' higher susceptibility to EMI/RFI and the increased environmental noise introduced by wireless-based systems, this produces a dangerous combination that could lead to logic errors, equipment damage, and faults in digital I and C. Failuresmore » to these systems, especially to safety-critical systems, could lead to loss of system, which would pose a safety risk and decrease in operational efficiency. In order to better understand system degradations by these means and aid in regulation and guidance, we propose to experimentally study the susceptibility of digital I and C to wireless technology. (authors)« less
Wi-Fi and health: review of current status of research.
Foster, Kenneth R; Moulder, John E
2013-12-01
This review summarizes the current state of research on possible health effects of Wi-Fi (a commercial name for IEEE 802.11-compliant wireless networking). In response to public concerns about health effects of Wi-Fi and wireless networks and calls by government agencies for research on possible health and safety issues with the technology, a considerable amount of technology-specific research has been completed. A series of high quality engineering studies have provided a good, but not complete, understanding of the levels of radiofrequency (RF) exposure to individuals from Wi-Fi. The limited number of technology-specific bioeffects studies done to date are very mixed in terms of quality and outcome. Unequivocally, the RF exposures from Wi-Fi and wireless networks are far below U.S. and international exposure limits for RF energy. While several studies report biological effects due to Wi-Fi-type exposures, technical limitations prevent drawing conclusions from them about possible health risks of the technology. The review concludes with suggestions for future research on the topic.
Traffic data collection and anonymous vehicle detection using wireless sensor networks.
DOT National Transportation Integrated Search
2012-05-01
New traffic sensing devices based on wireless sensing technologies were designed and tested. Such devices encompass a cost-effective, battery-free, and energy self-sustained architecture for real-time traffic measurement over distributed points in a ...
Poly[diaquatris(μ4-1,3-phenylenediacetato)dineodymium(III)
Gao, Zhu-Qing; Lv, Dong-Yu; Li, Hong-Ji; Gu, Jin-Zhong
2011-01-01
In the title coordination polymer, [Nd2(C10H8O4)3(H2O)2]n, each of the two NdIII ions is nine-coordinated by eight O atoms from six different 2,2′-(m-phenylene)diacetate (pda) bivalent anions and by one O atom from a water molecule, forming a distorted tricapped trigonal–prismatic coordination geometry. Eight NdIII ions and 12 pda ligands form a large [Nd8(pda)12] ring, and four NdIII ions and six pda ligands form a small [Nd4(pda)6] ring. These rings are further connected by the coordination interactions of pda ligands and NdIII, generating a three-dimensional supramolecular framework. PMID:21522305
A Review of Assistive Listening Device and Digital Wireless Technology for Hearing Instruments
Kim, Chun Hyeok
2014-01-01
Assistive listening devices (ALDs) refer to various types of amplification equipment designed to improve the communication of individuals with hard of hearing to enhance the accessibility to speech signal when individual hearing instruments are not sufficient. There are many types of ALDs to overcome a triangle of speech to noise ratio (SNR) problems, noise, distance, and reverberation. ALDs vary in their internal electronic mechanisms ranging from simple hard-wire microphone-amplifier units to more sophisticated broadcasting systems. They usually use microphones to capture an audio source and broadcast it wirelessly over a frequency modulation (FM), infra-red, induction loop, or other transmission techniques. The seven types of ALDs are introduced including hardwire devices, FM sound system, infra-red sound system, induction loop system, telephone listening devices, television, and alert/alarm system. Further development of digital wireless technology in hearing instruments will make possible direct communication with ALDs without any accessories in the near future. There are two technology solutions for digital wireless hearing instruments improving SNR and convenience. One is near-field magnetic induction combined with Bluetooth radio frequency (RF) transmission or proprietary RF transmission and the other is proprietary RF transmission alone. Recently launched digital wireless hearing aid applying this new technology can communicate from the hearing instrument to personal computer, phones, Wi-Fi, alert systems, and ALDs via iPhone, iPad, and iPod. However, it comes with its own iOS application offering a range of features but there is no option for Android users as of this moment. PMID:25566400
A review of assistive listening device and digital wireless technology for hearing instruments.
Kim, Jin Sook; Kim, Chun Hyeok
2014-12-01
Assistive listening devices (ALDs) refer to various types of amplification equipment designed to improve the communication of individuals with hard of hearing to enhance the accessibility to speech signal when individual hearing instruments are not sufficient. There are many types of ALDs to overcome a triangle of speech to noise ratio (SNR) problems, noise, distance, and reverberation. ALDs vary in their internal electronic mechanisms ranging from simple hard-wire microphone-amplifier units to more sophisticated broadcasting systems. They usually use microphones to capture an audio source and broadcast it wirelessly over a frequency modulation (FM), infra-red, induction loop, or other transmission techniques. The seven types of ALDs are introduced including hardwire devices, FM sound system, infra-red sound system, induction loop system, telephone listening devices, television, and alert/alarm system. Further development of digital wireless technology in hearing instruments will make possible direct communication with ALDs without any accessories in the near future. There are two technology solutions for digital wireless hearing instruments improving SNR and convenience. One is near-field magnetic induction combined with Bluetooth radio frequency (RF) transmission or proprietary RF transmission and the other is proprietary RF transmission alone. Recently launched digital wireless hearing aid applying this new technology can communicate from the hearing instrument to personal computer, phones, Wi-Fi, alert systems, and ALDs via iPhone, iPad, and iPod. However, it comes with its own iOS application offering a range of features but there is no option for Android users as of this moment.
The USU medical PDA initiative: the PDA as an educational tool.
Moore, Leon; Richardson, Bradley R; Williams, Robert W
2002-01-01
A medical personal digital assistant (PDA) initiative for healthcare students began in 2000 at the Uniformed Services University of the Health Sciences (USU). The University issued PDAs to Graduate School of Nursing (GSN) and School of Medicine (SOM) students. These devices were used to provide clinical reference material to the students, to facilitate clinical experience log collection, and the normal organizer functions of a PDA. Both medical and graduate nursing students were surveyed both before and during clinical training to determine the perceived usefulness of the PDA. A quantitative approach was utilized to emphasize the measurable variables.
Value of audio-enhanced handheld computers over paper surveys with adolescents.
Trapl, Erika S; Taylor, H Gerry; Colabianchi, Natalie; Litaker, David; Borawski, Elaine A
2013-01-01
To examine the impact of 3 data collection modes on the number of questions answered, data quality, and student preference. 275 urban seventh-grade students were recruited and randomly assigned to complete a paper survey (SAQ), PDA survey (PDA), or PDA survey with audio (APDA). Students completed a paper debriefing survey. APDA respondents completed significantly more questions compared to SAQ and PDA. PDA and APDA had significantly less missing data than did SAQ. No differences were found for student evaluation. Strong benefits may be gained by the use of APDA for adolescent school-based data collection.
Camouflage Traffic: Minimizing Message Delay for Smart Grid Applications under Jamming
2014-04-01
technologies. To facilitate efficient information exchange, wireless networks have been proposed to be widely used in the smart grid. However, the jamming...attack that constantly broadcasts radio interference is a primary security threat to prevent the deployment of wireless networks in the smart grid. Hence... wireless communications, while at the same time providing latency guarantee for control messages. An open question is how to minimize message delay for
2015-11-01
more detail. Table 1: Overview of DARPA Programs Selected for GAO Case Study Analyses Program name Program description Advanced Wireless Networks ...Selected DARPA Programs Program name According to DARPA portfolio-level database According to GAO analysis Advanced Wireless Networks for the Soldier...with potential transition partners Achievement of clearly defined technical goals Successful transition Advanced Wireless Networks for Soldier
Wireless Multiplexed Surface Acoustic Wave Sensors Project
NASA Technical Reports Server (NTRS)
Youngquist, Robert C.
2014-01-01
Wireless Surface Acoustic Wave (SAW) Sensor is a new technology for obtaining multiple, real-time measurements under extreme environmental conditions. This project plans to develop a wireless multiplexed sensor system that uses SAW sensors, with no batteries or semiconductors, that are passive and rugged, can operate down to cryogenic temperatures and up to hundreds of degrees C, and can be used to sense a wide variety of parameters over reasonable distances (meters).
Smart Grid Communications System Blueprint
NASA Astrophysics Data System (ADS)
Clark, Adrian; Pavlovski, Chris
2010-10-01
Telecommunications operators are well versed in deploying 2G and 3G wireless networks. These networks presently support the mobile business user and/or retail consumer wishing to place conventional voice calls and data connections. The electrical power industry has recently commenced transformation of its distribution networks by deploying smart monitoring and control devices throughout their networks. This evolution of the network into a `smart grid' has also motivated the need to deploy wireless technologies that bridge the communication gap between the smart devices and information technology systems. The requirements of these networks differ from traditional wireless networks that communications operators have deployed, which have thus far forced energy companies to consider deploying their own wireless networks. We present our experience in deploying wireless networks to support the smart grid and highlight the key properties of these networks. These characteristics include application awareness, support for large numbers of simultaneous cell connections, high service coverage and prioritized routing of data. We also outline our target blueprint architecture that may be useful to the industry in building wireless and fixed networks to support the smart grid. By observing our experiences, telecommunications operators and equipment manufacturers will be able to augment their current networks and products in a way that accommodates the needs of the emerging industry of smart grids and intelligent electrical networks.
Oncolytic Activity of Avian Influenza Virus in Human Pancreatic Ductal Adenocarcinoma Cell Lines
Pizzuto, Matteo S.; Silic-Benussi, Micol; Pavone, Silvia; Ciminale, Vincenzo; Capua, Ilaria
2014-01-01
ABSTRACT Pancreatic ductal adenocarcinoma (PDA) is the most lethal form of human cancer, with dismal survival rates due to late-stage diagnoses and a lack of efficacious therapies. Building on the observation that avian influenza A viruses (IAVs) have a tropism for the pancreas in vivo, the present study was aimed at testing the efficacy of IAVs as oncolytic agents for killing human PDA cell lines. Receptor characterization confirmed that human PDA cell lines express the alpha-2,3- and the alpha-2,6-linked glycan receptor for avian and human IAVs, respectively. PDA cell lines were sensitive to infection by human and avian IAV isolates, which is consistent with this finding. Growth kinetic experiments showed preferential virus replication in PDA cells over that in a nontransformed pancreatic ductal cell line. Finally, at early time points posttreatment, infection with IAVs caused higher levels of apoptosis in PDA cells than gemcitabine and cisplatin, which are the cornerstone of current therapies for PDA. In the BxPC-3 PDA cell line, apoptosis resulted from the engagement of the intrinsic mitochondrial pathway. Importantly, IAVs did not induce apoptosis in nontransformed pancreatic ductal HPDE6 cells. Using a model based on the growth of a PDA cell line as a xenograft in SCID mice, we also show that a slightly pathogenic avian IAV significantly inhibited tumor growth following intratumoral injection. Taken together, these results are the first to suggest that IAVs may hold promise as future agents of oncolytic virotherapy against pancreatic ductal adenocarcinomas. IMPORTANCE Despite intensive studies aimed at designing new therapeutic approaches, PDA still retains the most dismal prognosis among human cancers. In the present study, we provide the first evidence indicating that avian IAVs of low pathogenicity display a tropism for human PDA cells, resulting in viral RNA replication and a potent induction of apoptosis in vitro and antitumor effects in vivo. These results suggest that slightly pathogenic IAVs may prove to be effective for oncolytic virotherapy of PDA and provide grounds for further studies to develop specific and targeted viruses, with the aim of testing their efficacy in clinical contexts. PMID:24899201
Masri, Samer; El Rassi, Issam; Arabi, Mariam; Tabbakh, Anas; Bitar, Fadi
2015-08-01
To compare the efficacy and safety of Amplatzer Duct Occluder II (ADOII) among the various patent ductus arteriosus (PDA) types, and to assess the association between development of aortic obstruction and the PDA type in terms of measurable parameters as the device angulation and distance of upper end protrusion into the aortic lumen. Retrospective cohort study involving 50 consecutive subjects who underwent ADO II device closure of PDA. The median age and weight at intervention were 13 months (5.5 months to 18 years) and 11 (6-67) kg respectively. The median smallest ductal diameter by angiography was 3.2 (1.9-5.4) mm. Thirty two patients had type A PDA, 5 had type C, 5 had type D, and 8 had type E. Residual shunt was seen in only 1 patient who had a tubular PDA and resolved within 2 months of the procedure. No device embolization or pulmonary side protrusion were noted. There was a 16% aortic protrusion rate. The median distance of protrusion of the upper end of the device into the aortic lumen was 3.1 (0-9) mm and the median angle formed between the aortic end of the device and the PDA take-off was 10.4 (0-80.6) degrees. These latter parameters of aortic obstruction were significantly higher in the non-conical PDA group as compared to the conical PDA. Nevertheless, there was no significant coarctation due to aortic retention disc protrusion. Device closure of PDA using the ADO II is a safe procedure for chosen types of PDA. We demonstrated a novel technique for objective assessment of device protrusion into the descending aorta based on measurable parameters. ADOII device closure of non-conical PDAs warrants closer follow ups. © 2015 Wiley Periodicals, Inc.
Sellmer, Anna; Bech, Bodil H; Bjerre, Jesper V; Schmidt, Michael R; Hjortdal, Vibeke E; Esberg, Gitte; Rittig, Søren; Henriksen, Tine B
2017-01-10
A patent ductus arteriosus (PDA) is frequently found in very preterm neonates and is associated with increased risk of morbidity and mortality. A shunt across a PDA can result in an unfavorable distribution of the cardiac output and may in turn result in poor renal perfusion. Urinary Neutrophil Gelatinase-associated Lipocalin (U-NGAL) is a marker of renal ischemia and may add to the evaluation of PDA. Our primary aim was to investigate if U-NGAL is associated with PDA in very preterm neonates. Secondary, to investigate whether U-NGAL and PDA are associated with AKI and renal dysfunction evaluated by fractional excretion of sodium (FENa) and urine albumin in a cohort of very preterm neonates. A cohort of 146 neonates born at a gestational age less than 32 weeks were consecutively examined with echocardiography for PDA and serum sodium, and urine albumin and sodium were measured on postnatal day 3 and U-NGAL and serum creatinine day 3 and 6. AKI was defined according to modified neonatal Acute Kidney Injury Network (AKIN) criteria. The association between U-NGAL and PDA was investigated. And secondly we investigated if PDA and U-NGAL was associated with AKI and renal dysfunction. U-NGAL was not associated with a PDA day 3 when adjusted for gestational age and gender. A PDA day 3 was not associated with AKI when adjusted for gestational age and gender; however, it was associated with urine albumin. U-NGAL was not associated with AKI, but was found to be associated with urine albumin and FENa. Based on our study U-NGAL is not considered useful as a diagnostic marker to identify very preterm neonates with a PDA causing hemodynamic changes resulting in early renal morbidity. The interpretation of NGAL in preterm neonates remains to be fully elucidated.
Network Centric Communications for Expeditionary or Carrier Strike Groups
2011-12-01
known as Modulating Retroreflector (MRR) mode. In this configuration, a source laser transmits a beam to an optical receiver which receives the...be adapted for use at sea and found that interference was a key issue. SPAWAR Systems Center Pacific has spent over a decade trying to address this...ad-hoc wireless technology non-proprietary and radio agnostic. One of the issues with wireless technologies used at sea is the issue of ― beam
Construct mine environment monitoring system based on wireless mesh network
NASA Astrophysics Data System (ADS)
Chen, Xin; Ge, Gengyu; Liu, Yinmei; Cheng, Aimin; Wu, Jun; Fu, Jun
2018-04-01
The system uses wireless Mesh network as a network transmission medium, and strive to establish an effective and reliable underground environment monitoring system. The system combines wireless network technology and embedded technology to monitor the internal data collected in the mine and send it to the processing center for analysis and environmental assessment. The system can be divided into two parts: the main control network module and the data acquisition terminal, and the SPI bus technology is used for mutual communication between them. Multi-channel acquisition and control interface design Data acquisition and control terminal in the analog signal acquisition module, digital signal acquisition module, and digital signal output module. The main control network module running Linux operating system, in which the transplant SPI driver, USB card driver and AODV routing protocol. As a result, the internal data collection and reporting of the mine are realized.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Feng, Philip
The research objective of this project is to design and demonstrate a low-cost, compact, easy-to-deploy, maintenance-free sensor node technology, and a network of such sensors, which enable the monitoring of multiphysical parameters and can transform today’s ordinary buildings into smart buildings with environmental awareness. We develop the sensor node and network via engineering and integration of existing technologies, including high-efficiency mechanical energy harvesting, and ultralow-power integrated circuits (ICs) for sensing and wireless communication. Through integration and innovative power management via specifically designed low-power control circuits for wireless sensing applications, and tailoring energy-harvesting components to indoor applications, the target products willmore » have smaller volume, higher efficiency, and much lower cost (in both manufacturing and maintenance) than the baseline technology. Our development and commercialization objective is to create prototypes for our target products under the CWRU-Intwine collaboration.« less
Wide modulation bandwidth terahertz detection in 130 nm CMOS technology
NASA Astrophysics Data System (ADS)
Nahar, Shamsun; Shafee, Marwah; Blin, Stéphane; Pénarier, Annick; Nouvel, Philippe; Coquillat, Dominique; Safwa, Amr M. E.; Knap, Wojciech; Hella, Mona M.
2016-11-01
Design, manufacturing and measurements results for silicon plasma wave transistors based wireless communication wideband receivers operating at 300 GHz carrier frequency are presented. We show the possibility of Si-CMOS based integrated circuits, in which by: (i) specific physics based plasma wave transistor design allowing impedance matching to the antenna and the amplifier, (ii) engineering the shape of the patch antenna through a stacked resonator approach and (iii) applying bandwidth enhancement strategies to the design of integrated broadband amplifier, we achieve an integrated circuit of the 300 GHz carrier frequency receiver for wireless wideband operation up to/over 10 GHz. This is, to the best of our knowledge, the first demonstration of low cost 130 nm Si-CMOS technology, plasma wave transistors based fast/wideband integrated receiver operating at 300 GHz atmospheric window. These results pave the way towards future large scale (cost effective) silicon technology based terahertz wireless communication receivers.
Real-time long term measurement using integrated framework for ubiquitous smart monitoring
NASA Astrophysics Data System (ADS)
Heo, Gwanghee; Lee, Giu; Lee, Woosang; Jeon, Joonryong; Kim, Pil-Joong
2007-04-01
Ubiquitous monitoring combining internet technologies and wireless communication is one of the most promising technologies of infrastructure health monitoring against the natural of man-made hazards. In this paper, an integrated framework of the ubiquitous monitoring is developed for real-time long term measurement in internet environment. This framework develops a wireless sensor system based on Bluetooth technology and sends measured acceleration data to the host computer through TCP/IP protocol. And it is also designed to respond to the request of web user on real time basis. In order to verify this system, real time monitoring tests are carried out on a prototype self-anchored suspension bridge. Also, wireless measurement system is analyzed to estimate its sensing capacity and evaluate its performance for monitoring purpose. Based on the evaluation, this paper proposes the effective strategies for integrated framework in order to detect structural deficiencies and to design an early warning system.
Measurement of agricultural parameters using wireless sensor network (WSN)
NASA Astrophysics Data System (ADS)
Guaña-Moya, Javier; Sánchez-Almeida, Tarquino; Salgado-Reyes, Nelson
2018-04-01
The technological advances have allowed to create new applications in telecommunications, applying low power and reduced costs in their equipment, thus achieving the evolution of new wireless networks or also denominated Wireless Sensor Network. These technologies allow the generation of measurements and analysis of environmental parameter data and soil. Precision agriculture requires parameters for the improvement of production, obtained through WSN technologies. This research analyzes the climatic requirements and soil parameters in a rose plantation in a greenhouse at an altitude of 3,100 meters above sea level. In the present investigation, maximum parameters were obtained in the production of roses, which are in the optimum range of production, whereas the minimum parameters of temperature, humidity and luminosity, evidenced that these parameters can damage the plants, since temperatures less than 10 °C slow down the growth of the plant and allow the proliferation of diseases and fungi.
NASA Astrophysics Data System (ADS)
Wang, Zhiqiang; Ren, Ruirui; Song, Haojie; Jia, Xiaohua
2018-01-01
Carbon nanotubes (CNTs) decorated with uniform copper nanoparticles (Cu NPs) were successfully prepared via a facile approach towards surface modification of CNTs with spontaneous polydopamine (PDA). The structures and morphologies of the nanocomposites were investigated by different kinds of techniques, including X-ray diffraction (XRD), transmission electron microscopy (TEM), and X-ray photoelectron spectroscopy (XPS). Cu/PDA/CNTs nanocomposites were fabricated by growing the Cu NPs with an average diameter of 5 nm on the surfaces of PDA-modified CNTs. The CNTs functionalized with PDA layer not only provide an anchoring platform for the Cu NPs immobilization, but also endow Cu/PDA/CNTs with good dispersion stability when Cu/PDA/CNTs nanocomposites were used as lubricant additive. The tribological performance of the nanocomposites as the rapeseed oil lubricant additive, as well as Cu NPs, CNTs, and Cu/CNTs, was also investigated using a MS-T3000 ball-on-disk tribometer. Results show that the 0.2 wt% Cu/PDA/CNTs nanoadditive simultaneously reduce the friction and wear by 33.5% and 23.7%, respectively, outperformed the tribological performance of Cu NPs, CNTs, and Cu/CNTs nanoadditives. In addition, the presence of active sites in Cu/PDA/CNTs was beneficial to reduce the time of running-in period, give rise to the fastest speed to be stable of the friction coefficient curve as compared to the other nanoadditives. X-ray photoelectron spectroscopy (XPS) and Raman spectroscopy of the worn surfaces lubricated by the soybean oil with Cu/PDA/CNTs nanocomposites showed that formation of low shear strength tribofilms containing Cu/PDA/CNTs nanocomposites and its self-lubricating property was key factor in reduction of the friction and protection against wear and deformation.
Slaughter, Jonathan L; Reagan, Patricia B; Bapat, Roopali V; Newman, Thomas B; Klebanoff, Mark A
2016-06-01
We surveyed neonatal leadership at 46 US children's hospitals via web-based survey to identify local preferences and concerns regarding indomethacin prophylaxis, nonsteroidal anti-inflammatory drug (NSAID) treatment, and patent ductus arteriosus (PDA) ligation. We received a 100 % survey response (N = 46). Practice guidelines for prophylactic indomethacin were reported at 28 % of NICUs, for NSAID treatment of PDA at 39 % and for surgical ligation at 27 %. Respondents noted intra-institutional practice variation for indomethacin prophylaxis (33 %), NSAID treatment (70 %), and PDA ligation (73 %). The majority of institutions did not prescribe indomethacin prophylaxis (72 %). For PDA treatment, indomethacin was preferred over ibuprofen (80 %). We validated our survey results via comparison with billing data as documented in the Pediatric Health Information System (PHIS) database, finding that survey responses directly correlated with local billing data (p < 0.0001). At institutions that did not typically administer NSAIDs for PDA closure or surgical PDA ligation, a lack of evidence for their effectiveness in improving long-term outcomes and the risk of treatment-associated adverse effects were the most often cited reasons. No consensus exists among providers at US children's hospitals regarding prophylactic indomethacin, NSAID treatment, or PDA ligation. Lack of evidence and safety concerns play a prominent role. • NSAIDs and surgical PDA ligation are efficacious in preventing intraventricular hemorrhage (IVH) and closing PDA in preterm infants, but have not been shown to improve long-term respiratory, neurodevelopmental, or mortality outcomes. What is New: • Practice preferences for indomethacin prophylaxis, NSAID, and surgical PDA treatment vary both among and within institutions. Lack of treatment effectiveness and the risk of adverse effects are major concerns.
Xiao, L Z; Ichikawa, S
1998-03-16
Mutagenic interactions between X-rays and two promutagens, o-phenylenediamine (PDA) and N-nitrosodimethylamine (DMN), were studied in the stamen hairs of Tradescantia clone BNL 4430, a blue/pink heterozygote. The young inflorescence-bearing shoots with roots of this clone cultivated in a nutrient solution circulating growth chamber were used as tester plants. After determining dose-response curves for X-rays. PDA and DMN, combined treatments with PDA or DMN and X-rays were conducted, exposing acutely to X-rays 20 h before starting, at the midpoint of, or 20 h after completing the PDA or DMN treatments for 4 h. Clear synergistic effects in inducing somatic pink mutations were detected when X-rays were irradiated before the PDA or DMN treatments, resembling those confirmed earlier between maleic hydrazide (MH) and X-rays. On the contrary, clear antagonistic effects were observed when X-rays were given after the PDA or DMN treatments, also resembling those between MH and X-rays. When X-rayed at the midpoint of the PDA or DMN treatments, merely additive and synergistic effects were observed, respectively, differing from the antagonistic effects between MH and X-rays. The mutagenic synergisms detected were considered to be the results of interactions between DNA strand breaks (and the resultant chromosome breaks) induced by X-rays and those by PDA or DMN, whereas the mutagenic antagonisms observed were presumed to be due to X-ray-caused inhibition of the activation of PDA and DMN in the stamen-hair cells. The time periods required for penetrations into floral tissues and/or activations into mutagens seem different among PDA, DMN and MH. Copyright 1998 Elsevier Science B.V.
NASA Astrophysics Data System (ADS)
Giel, V.; Perchacz, M.; Kredatusová, J.; Pientka, Z.
2017-01-01
Functionalised titanate nanotubes (TiNTs) were incorporated to poly(5,5-bisbenzimidazole-2,2-diyl-1,3-phenylene) (PBI) or poly(2,6-dimethyl-1,4-phenylene oxide) (PPO) for improving the interfacial compatibility between the polymer matrix and inorganic material and for altering the gas separation performance of the neat polymer membranes. Functionalisation consisted in oxidative polymerisation of dopamine-hydrochloride on the surface of non-functionalised TiNTs. Transmission electron microscopy (TEM) confirmed that a thin polydopamine (PDA) layer was created on the surface of TiNTs. 1.5, 3, 6, and 9 wt.% of PDA-functionalised TiNTs (PDA-TiNTs) were dispersed to each type of polymer matrix to create so-called mixed matrix membranes (MMMs). Infrared spectroscopy confirmed that -OH and -NH groups exist on the surface of PDA-TiNTs and that the nanotubes interact via H-bonding with PBI but not with PPO. The distribution of PDA-TiNTs in the MMMs was to some extent uniform as scanning electron microscope (SEM) studies showed. Beyond, PDA-TiNTs exhibit positive effect on gas transport properties, resulting in increased selectivities of MMMs. The addition of nanotubes caused a decrease in permeabilities but an increase in selectivities. It is shown that 9 wt.% of PDA-TiNTs in PBI gave a rise to CO2/N2 and CO2/CH4 selectivities of 112 and 63 %, respectively. In case of PPO-PDA-TiNT MMMs, CO2/N2 and CO2/CH4 selectivity increased about 25 and 17 %, respectively. Sorption measurement showed that the presence of PDA-TiNTs in PBI caused an increase in CO2 sorption, whereas the influence on other gases is less noticeable.
Kiran, Viralam S; Tiwari, Ashish
2018-04-06
The aims of this study were to determine the incidence and correlates of left ventricular (LV) dysfunction amongst percutaneous patent ductus arteriosus (PDA) device closure patients, and to propose an indexed parameter for predicting LV dysfunction. In a retrospective cross-sectional analysis of 30 months duration, 447 patients who underwent PDA device closure were studied. The diameter of the PDA at the pulmonary artery end was measured in the angiograms in all patients and was indexed for their body surface area. The indexed PDA size was categorised into group A (1-2.9 mm/m², 35/447), B (3-5.9 mm/m², 254/447), C (6-8.9 mm/m², 66/447) and D (>9 mm/m², 35/447). Systolic LV function was evaluated using echocardiography at frequent intervals. Overall, 62.63% of the patients were female (280/447). At baseline, all 447 patients had normal LV function. LV dysfunction was seen in 102/447 (22.8%) patients with 2.8% in category A (1/35), 10.6% in category B (27/254), 34.1% in category C (42/123) and 91.4% in category D (32/35) after PDA device closure. Correlation of indexed PDA size and LV dysfunction was statistically significant (p<0.05). Accurate prediction of LV dysfunction is important in risk stratification, ICU management and counselling in PDA device closures. Indexed PDA size correlates well with post-procedural LV dysfunction. The authors propose a new classification of PDA utilising this accurate, reproducible and easy to perform parameter, which does not involve any extra cost, for risk stratification and early management in device closure of PDA.
Prevalence and management of patent ductus arteriosus in a pediatric medicaid cohort.
Tripathi, Avnish; Black, George B; Park, Yong-Moon Mark; Jerrell, Jeanette M
2013-09-01
Widespread use of echocardiography has made earlier diagnosis of patent ductus arteriosus (PDA) possible, but pharmacological or surgical intervention is highly variable. Herein, we investigate the prevalence of PDA and its management in a routine care system. A 15-year retrospective dataset (1996-2010) was analyzed. Selection criteria included age ≤17 years, enrollees in South Carolina State Medicaid, and diagnosed as having PDA on 1 or more service visits to a pediatrician or pediatric cardiologist. The 15-year treated prevalence rate of PDA was 0.25/1000 pediatric cases of congenital heart disease (CHD). PDA was more prevalent in non-African American patients (adjusted odds ratio [aOR]: 1.12), but not in females after controlling for all other CHDs diagnosed in the cohort. Associated CHDs were present in 57.6% of the cases, primarily atrial or ventricular septal defects, and fewer patients (5.5%) developed pulmonary hypertension. Of 3627 PDA cases examined, 70.0% received no medications or PDA repair. Therapeutic ibuprofen was used for closure in 24.4% of the cases, and a PDA repair was performed in 7.8%. Younger children (aOR: 0.82), those who received an atrial septal defect closure (aOR: 5.18), and those who were treated with digoxin (aOR: 1.86) or with diuretics or preload/afterload reducing agents (ie, calcium channel blockers or angiotensin-converting enzyme inhibitors) (aOR: 5.72) were significantly more likely to have a PDA repair procedure. The majority of diagnosed PDA cases did not require pharmacological or surgical intervention. Those receiving pharmacological or surgical intervention were treated conservatively in relation to the presence of distress symptoms or concomitant CHDs requiring intervention. © 2013 Wiley Periodicals, Inc.
Shi, Jiafu; Yang, Chen; Zhang, Shaohua; Wang, Xiaoli; Jiang, Zhongyi; Zhang, Wenyan; Song, Xiaokai; Ai, Qinghong; Tian, Chunyong
2013-10-23
Microcapsules with diverse wall structures may exhibit different performance in specific applications. In the present study, three kinds of mussel-inspired polydopamine (PDA) microcapsules with different wall structures have been prepared by a template-mediated method. More specifically, three types of CaCO3 microspheres (poly(allylamine hydrochloride), (PAH)-doped CaCO3; pure-CaCO3; and poly(styrene sulfonate sodium), (PSS)-doped CaCO3) were synthesized as sacrificial templates, which were then treated by dopamine to obtain the corresponding PDA-CaCO3 microspheres. Through treating these microspheres with disodium ethylene diamine tetraacetic acid (EDTA-2Na) to remove CaCO3, three types of PDA microcapsules were acquired: that was (1) PAH-PDA microcapsule with a thick (∼600 nm) and highly porous capsule wall composed of interconnected networks, (2) pure-PDA microcapsule with a thick (∼600 nm) and less porous capsule wall, (3) PSS-PDA microcapsule with a thin (∼70 nm) and dense capsule wall. Several characterizations confirmed that a higher degree in porosity and interconnectivity of the capsule wall would lead to a higher mass transfer coefficient. When serving as the carrier for catalase (CAT) immobilization, these enzyme-encapsulated PDA microcapsules showed distinct structure-related activity and stability. In particular, PAH-PDA microcapsules with a wall of highly interconnected networks displayed several significant advantages, including increases in enzyme encapsulation efficiency and enzyme activity/stability and a decrease in enzyme leaching in comparison with other two types of PDA microcapsules. Besides, this hierarchically structured PAH-PDA microcapsule may find other promising applications in biocatalysis, biosensors, drug delivery, etc.
DOT National Transportation Integrated Search
1997-06-06
Shared resource projects offer an opportunity for public transportation agencies to leverage property assets in exchange for support for transportation programs. Intelligent transportation systems (ITS) require wireline infrastructure in roadway ROW ...
Handheld Devices: Toward a More Mobile Campus.
ERIC Educational Resources Information Center
Fallon, Mary A. C.
2002-01-01
Offers an overview of the acceptance and use of handheld personal computing devices on campus that connect wirelessly to the campus network. Considers access; present and future software applications; uses in medial education; faculty training needs; and wireless technology issues. (Author/LRW)
NASA Astrophysics Data System (ADS)
Ivo, Penn
2004-04-01
Bluetooth is the new emerging technology for wireless communication. It can be used to connect almost any device to another device. The traditional example is to link a Personal Digital Assistant (PDA) or a laptop to a mobile phone. That way you can easily take remote connections with your PDA or laptop without getting your mobile phone from your pocket or messing around with cables. A Class 3 Bluetooth device has range of 0,1 - 10 meters. The architecture of Bluetooth is formed by the radio, the base frequency part and the Link Manager. Bluetooth uses the radio range of 2.45 GHz. The theoretical maximum bandwidth is 1 Mb/s, which is slowed down a bit by Forward Error Correction (FEC). Bluetooth specification designates the frequency hopping to be implemented with Gaussian Frequency Shift Keying (GFSK). The base frequency part of the Bluetooth architecture uses a combination of circuit and packet switching technologies. Bluetooth can support either one asynchronous data channel and up to three simultaneous synchronous speech channels, or one channel that transfers asynchronous data and synchronous speech simultaneously. The Link Manager is an essential part of the Bluetooth architecture. It uses Link Manager Protocol (LMP) to configure, authenticate and handle the connections between Bluetooth devices. Several Bluetooth devices can form an ad hoc network. In these piconets, one of the Bluetooth devices will act as a master and the others are slaves. The master sets the frequency-hopping behavior of the piconet. It is also possible to connect up to 10 piconets to each other to form so-called scatternets. Bluetooth has been designed to operate in noisy radio frequency environments, and uses a fast acknowledgement and frequency-hopping scheme to make the link robust, communication-wise. Bluetooth radio modules avoid interference from other signals by hopping to a new frequency after transmitting or receiving a packet. Compared with other systems operating in the same frequency band, the Bluetooth radio typically hops faster and uses shorter packets. This is because short packages and fast hopping limit the impact of microwave ovens and other sources of disturbances. Use of Forward Error Correction (FEC) limits the impact of random noise on long-distance links. Bluetooth transmissions are secure in a business and home environment. Bluetooth has built in sufficient encryption and authentication and is thus very secure in any environment. In addition to this, a frequency-hopping scheme with 1600 hops/sec. is employed. This is far quicker than any other competing system. This, together with an automatic output power adaption to reduce the range exactly to requirement, makes the system extremely difficult to eavesdrop. Information Integrity in Bluetooth has these components: Random Number Generation, Encryption, Encryption Key Management and Authentication.
Thin film resonator technology.
Lakin, Kenneth M
2005-05-01
Advances in wireless systems have placed increased demands on high performance frequency control devices for operation into the microwave range. With spectrum crowding, high bandwidth requirements, miniaturization, and low cost requirements as a background, the thin film resonator technology has evolved into the mainstream of applications. This technology has been under development for over 40 years in one form or another, but it required significant advances in integrated circuit processing to reach microwave frequencies and practical manufacturing for high-volume applications. This paper will survey the development of the thin film resonator technology and describe the core elements that give rise to resonators and filters for today's high performance wireless applications.
NASA Astrophysics Data System (ADS)
Li, Bing; Chen, Ye; Ge, Xiaoming; Chai, Jianwei; Zhang, Xiao; Hor, T. S. Andy; Du, Guojun; Liu, Zhaolin; Zhang, Hua; Zong, Yun
2016-02-01
Transition metal and nitrogen co-doping into carbon is an effective approach to promote the catalytic activities towards the oxygen reduction reaction (ORR) and/or oxygen evolution reaction (OER) in the resultant electrocatalysts, M/N-C. The preparation of such catalysts, however, is often complicated and in low yield. Herein we report a robust approach for easy synthesis of M/N-C hybrids in high yield, which includes a mussel-inspired polymerization reaction at room temperature and a subsequent carbonization process. With the introduction of selected transition metal salts into an aqueous solution of dopamine (DA), the obtained mixture self-polymerizes to form metal-containing polydopamine (M-PDA) composites, e.g. Co-PDA, Ni-PDA and Fe-PDA. Upon carbonization at elevated temperatures, these metal-containing composites were converted into M/N-C, i.e. Co-PDA-C, Ni-PDA-C and Fe-PDA-C, respectively, whose morphologies, chemical compositions, and electrochemical performances were fully studied. Enhanced ORR activities were found in all the obtained hybrids, with Co-PDA-C standing out as the most promising catalyst with excellent stability and catalytic activities towards both ORR and OER. This was further proven in Zn-air batteries (ZnABs) in terms of discharge voltage stability and cycling performance. At a discharge-charge current density of 2 mA cm-2 and 1 h per cycle, the Co-PDA-C based ZnABs were able to steadily cycle up to 500 cycles with only a small increase in the discharge-charge voltage gap which notably outperformed Pt/C; at a discharge current density of 5 mA cm-2, the battery continuously discharged for more than 540 h with the discharge voltage above 1 V and a voltage drop rate of merely 0.37 mV h-1. With the simplicity and scalability of the synthetic approach and remarkable battery performances, the Co-PDA-C hybrid catalyst is anticipated to play an important role in practical ZnABs.Transition metal and nitrogen co-doping into carbon is an effective approach to promote the catalytic activities towards the oxygen reduction reaction (ORR) and/or oxygen evolution reaction (OER) in the resultant electrocatalysts, M/N-C. The preparation of such catalysts, however, is often complicated and in low yield. Herein we report a robust approach for easy synthesis of M/N-C hybrids in high yield, which includes a mussel-inspired polymerization reaction at room temperature and a subsequent carbonization process. With the introduction of selected transition metal salts into an aqueous solution of dopamine (DA), the obtained mixture self-polymerizes to form metal-containing polydopamine (M-PDA) composites, e.g. Co-PDA, Ni-PDA and Fe-PDA. Upon carbonization at elevated temperatures, these metal-containing composites were converted into M/N-C, i.e. Co-PDA-C, Ni-PDA-C and Fe-PDA-C, respectively, whose morphologies, chemical compositions, and electrochemical performances were fully studied. Enhanced ORR activities were found in all the obtained hybrids, with Co-PDA-C standing out as the most promising catalyst with excellent stability and catalytic activities towards both ORR and OER. This was further proven in Zn-air batteries (ZnABs) in terms of discharge voltage stability and cycling performance. At a discharge-charge current density of 2 mA cm-2 and 1 h per cycle, the Co-PDA-C based ZnABs were able to steadily cycle up to 500 cycles with only a small increase in the discharge-charge voltage gap which notably outperformed Pt/C; at a discharge current density of 5 mA cm-2, the battery continuously discharged for more than 540 h with the discharge voltage above 1 V and a voltage drop rate of merely 0.37 mV h-1. With the simplicity and scalability of the synthetic approach and remarkable battery performances, the Co-PDA-C hybrid catalyst is anticipated to play an important role in practical ZnABs. Electronic supplementary information (ESI) available: Schematic structure of ZnAB; photos of home-made ZnABs; EDX spectra and elemental mapping of M-PDA-C; N2 adsorption/desorption isotherms, high magnification TEM images of M-PDA-C, and RDE data of M-PDA-C, etc. See DOI: 10.1039/c5nr06538k