Solar-powered turbocompressor heat pump system
Landerman, A.M.; Biancardi, F.R.; Melikian, G.; Meader, M.D.; Kepler, C.E.; Anderson, T.J.; Sitler, J.W.
1982-08-12
The turbocompressor comprises a power turbine and a compressor turbine having respective rotors and on a common shaft, rotatably supported by bearings. A first working fluid is supplied by a power loop and is expanded in the turbine. A second working fluid is compressed in the turbine and is circulated in a heat pump loop. A lubricant is mixed with the second working fluid but is excluded from the first working fluid. The bearings are cooled and lubricated by a system which circulates the second working fluid and the intermixed lubricant through the bearings. Such system includes a pump, a thermostatic expansion valve for expanding the working fluid into the space between the bearings, and a return conduit system for withdrawing the expanded working fluid after it passes through the bearings and for returning the working fluid to the evaporator. A shaft seal excludes the lubricant from the power turbine. The power loop includes a float operable by liquid working fluid in the condenser for controlling a recirculation valve so as to maintain a minimum liquid level in the condenser, while causing a feed pump to pump most of the working fluid into the vapor generator. The heat pump compressor loop includes a float in the condenser for operating and expansion valve to maintain a minimum liquid working fluid level in the condenser while causing most of the working fluid to be expanded into the evaporator.
Kalina, Alexander I.
1984-01-01
A method of generating energy which comprises utilizing relatively lower temperature available heat to effect partial distillation of at least portion of a multicomponent working fluid stream at an intermediate pressure to generate working fluid fractions of differing compositions. The fractions are used to produce at least one main rich solution which is relatively enriched with respect to the lower boiling component, and to produce at least one lean solution which is relatively improverished with respect to the lower boiling component. The pressure of the main rich solution is increased whereafter it is evaporated to produce a charged gaseous main working fluid. The main working fluid is expanded to a low pressure level to release energy. The spent low pressure level working fluid is condensed in a main absorption stage by dissolving with cooling in the lean solution to regenerate an initial working fluid for reuse.
Numerical Modelling of Three-Fluid Flow Using The Level-set Method
NASA Astrophysics Data System (ADS)
Li, Hongying; Lou, Jing; Shang, Zhi
2014-11-01
This work presents a numerical model for simulation of three-fluid flow involving two different moving interfaces. These interfaces are captured using the level-set method via two different level-set functions. A combined formulation with only one set of conservation equations for the whole physical domain, consisting of the three different immiscible fluids, is employed. Numerical solution is performed on a fixed mesh using the finite volume method. Surface tension effect is incorporated using the Continuum Surface Force model. Validation of the present model is made against available results for stratified flow and rising bubble in a container with a free surface. Applications of the present model are demonstrated by a variety of three-fluid flow systems including (1) three-fluid stratified flow, (2) two-fluid stratified flow carrying the third fluid in the form of drops and (3) simultaneous rising and settling of two drops in a stationary third fluid. The work is supported by a Thematic and Strategic Research from A*STAR, Singapore (Ref. #: 1021640075).
Apparatus for downward transport of heat
Neeper, D.A.; Hedstrom, J.C.
1985-08-05
An apparatus for the downward transport of heat by vaporization of a working fluid, usually from a collector which can be powered by the sun to a condenser which drains the condensed working fluid to a lower reservoir, is controled by a control valve which is operationally dependent upon the level of working fluid in either the lower reservoir or an upper reservoir which feeds the collector. Condensed working fluid is driven from the lower to the upper reservoir by vaporized working fluid whose flow is controled by the controll valve. The upper reservoir is in constant communication with the condenser which prevents a buildup in temperature/pressure as the apparatus goes through successive pumping cycles.
NASA Technical Reports Server (NTRS)
Perry, Jay L.; Arnold, William a.
2006-01-01
The design and operation of crewed spacecraft requires identifying and evaluating chemical compounds that may present reactivity and compatibility risks with the environmental control and life support (ECLS) system. Such risks must be understood so that appropriate design and operational controls, including specifying containment levels, can be instituted or an appropriate substitute material selected. Operational experience acquired during the International Space Station (ISS) program has found that understanding ECLS system and environmental impact presented by thermal control system working fluids is imperative to safely operating any crewed space exploration vehicle. Perfluorocarbon fluids are used as working fluids in thermal control fluid loops on board the ISS. Also, payload hardware developers have identified perfluorocarbon fluids as preferred thermal control working fluids. Interest in using perfluorocarbon fluids as thermal control system working fluids for future crewed space vehicles and outposts is high. Potential hazards associated with perfluorocarbon fluids are discussed with specific attention given to engineering assessment of ECLS system compatibility, compatibility testing results, and spacecraft environmental impact. Considerations for perfluorocarbon fluid use on crewed spacecraft and outposts are summarized.
Rankine cycle system and method
Ernst, Timothy C.; Nelson, Christopher R.
2014-09-09
A Rankine cycle waste heat recovery system uses a receiver with a maximum liquid working fluid level lower than the minimum liquid working fluid level of a sub-cooler of the waste heat recovery system. The receiver may have a position that is physically lower than the sub-cooler's position. A valve controls transfer of fluid between several of the components in the waste heat recovery system, especially from the receiver to the sub-cooler. The system may also have an associated control module.
Wireless Fluid-Level Sensors for Harsh Environments
NASA Technical Reports Server (NTRS)
Woodward, Stanley E.
2009-01-01
Magnetic-field-response sensors have been developed for use in measuring levels of fluids under extreme conditions. The sensors work without wire connections or direct physical contact with power sources, microprocessors, data-acquisition equipment, or electrical circuitry. For fuel-level sensors, the absence of wire connections offers an important safety advantage in elimination of potential ignition sources.
Preliminary results from a four-working space, double-acting piston, Stirling engine controls model
NASA Technical Reports Server (NTRS)
Daniele, C. J.; Lorenzo, C. F.
1980-01-01
A four working space, double acting piston, Stirling engine simulation is being developed for controls studies. The development method is to construct two simulations, one for detailed fluid behavior, and a second model with simple fluid behaviour but containing the four working space aspects and engine inertias, validate these models separately, then upgrade the four working space model by incorporating the detailed fluid behaviour model for all four working spaces. The single working space (SWS) model contains the detailed fluid dynamics. It has seven control volumes in which continuity, energy, and pressure loss effects are simulated. Comparison of the SWS model with experimental data shows reasonable agreement in net power versus speed characteristics for various mean pressure levels in the working space. The four working space (FWS) model was built to observe the behaviour of the whole engine. The drive dynamics and vehicle inertia effects are simulated. To reduce calculation time, only three volumes are used in each working space and the gas temperature are fixed (no energy equation). Comparison of the FWS model predicted power with experimental data shows reasonable agreement. Since all four working spaces are simulated, the unique capabilities of the model are exercised to look at working fluid supply transients, short circuit transients, and piston ring leakage effects.
Ultraviolet resonance Raman spectroscopy for the detection of cocaine in oral fluid
NASA Astrophysics Data System (ADS)
D'Elia, Valentina; Montalvo, Gemma; Ruiz, Carmen García; Ermolenkov, Vladimir V.; Ahmed, Yasmine; Lednev, Igor K.
2018-01-01
Detecting and quantifying cocaine in oral fluid is of significant importance for practical forensics. Up to date, mainly destructive methods or biochemical tests have been used, while spectroscopic methods were only applied to pretreated samples. In this work, the possibility of using resonance Raman spectroscopy to detect cocaine in oral fluid without pretreating samples was tested. It was found that ultraviolet resonance Raman spectroscopy with 239-nm excitation allows for the detection of cocaine in oral fluid at 10 μg/mL level. Further method development will be needed for reaching the practically useful levels of cocaine detection.
Power enhancement of heat engines via correlated thermalization in a three-level "working fluid".
Gelbwaser-Klimovsky, David; Niedenzu, Wolfgang; Brumer, Paul; Kurizki, Gershon
2015-09-23
We explore means of maximizing the power output of a heat engine based on a periodically-driven quantum system that is constantly coupled to hot and cold baths. It is shown that the maximal power output of such a heat engine whose "working fluid" is a degenerate V-type three-level system is that generated by two independent two-level systems. Hence, level degeneracy is a thermodynamic resource that may effectively double the power output. The efficiency, however, is not affected. We find that coherence is not an essential asset in such multilevel-based heat engines. The existence of two thermalization pathways sharing a common ground state suffices for power enhancement.
NASA Astrophysics Data System (ADS)
Kusagaya, T.; Uchida, T.; Tanaka, H. K. M.; Tanaka, M.
2012-04-01
We will present a real-time monitoring system for cosmic-ray muon radiography as an application of a readout module developed by T. Uchida et al [1,2]. The readout module was developed originally for probing the internal structure of volcanoes in 2008 [3]. Its features are small in size, low power consumption, and the capability to access remotely via Ethernet. The current statistics data of cosmic-ray muons can be read from a PC placed far from the module at anytime. By using this feature, we constructed a real-time monitoring system. As a test experiment, we observed fluid movement in a cylinder with a diameter of 112 meters water equivalent. In this work, we succeeded to resolve the fluid movement in the cylinder. We varied the fluid level inside the cylinder and measured the muon intensity. We found that the muon intensity correlates inversely with the fluid level: the muon intensity increases for the lower fluid level and decreases for the higher fluid level. Although the time resolution of muon radiography was sufficient to resolve changes in the fluid level, an adequate time window has to be chosen for different operating conditions. We anticipate that this system will be applicable to exploring high-speed phenomena in a gigantic object.
Balsamo, Ana Cristina; Felli, Vanda Elisa Andres
2006-01-01
This descriptive and exploratory study from a quantitative approach aimed to characterize workers who were victims of work accidents related to human body fluids exposure and to evaluate the accident victim care protocol. The population consisted of 48 workers who were victims of work accidents involving exposure to human body fluids, from July 2000 to June 2001. Data were collected through a form and interviews. Results showed that nursing workers presented higher accident risk levels and that 87.50% involved piercing and cutting material, such as needles and butterflies (70%). As to the accident-related situation/activity, the workers indicated that 25% were due to an "inadequate act during the procedure"; 19.64% mentioned that "it happened" and 29.17% answered that they did not have any suggestion. This study provided important tools to review and elaborate strategies to prevent accidents involving exposure to human body fluids.
... work the way they should Sodium, calcium, potassium, chlorine, phosphate, and magnesium are all electrolytes. You get them from the foods you eat and the fluids you drink. The levels of electrolytes in your body can become too low or too high. This can happen when the amount of water ...
Measurement of interstage fluid-annulus dynamical properties
NASA Technical Reports Server (NTRS)
Adams, M. L.; Makay, E.; Diaz-Tous, I. A.
1982-01-01
The work described in this paper is part of an Electric Power Research Institute sponsored effort to improve rotor vibrational performance on power plant feed water pumps. A major objective of this effort is to reduce vibration levels by devising inter-stage sealing configurations with optimized damping capacity, realizing that the typical multi-stage centrifugal pump has several ore inter-stage fluid annuli than it has journal bearings. Also, the fluid annuli are distributed between the journal bearings where vibration levels are highest and can therefore be 'exercised' more as dampers than can the bearings. Described in this paper is a test apparatus which has been built to experimentally determine fluid-annulus dynamical coefficients for various configurations of inter-stage sealing geometry.
Fluid-electrolyte shifts and maximal oxygen uptake in man at simulated altitude /2,287 m/
NASA Technical Reports Server (NTRS)
Greenleaf, J. E.; Bernauer, E. M.; Adams, W. C.; Juhos, L.
1978-01-01
Experiments were conducted on six trained distance runners (21-23 yr) subjected to an eight-day dietary control at sea level, followed by an eight-day stay in an altitude chamber (2287-m altitude) and a four-day recovery at sea level. Fluid and electrolyte shifts during exercise at altitude were evaluated to gain insight into the mechanism of reduction in working capacity. The results are discussed in terms of resting fluid volumes and blood constituents, maximal exercise variables, and maximal exercise fluid-electrolyte shifts. Since there are no significant changes in fluid balance or resting plasma volume (PV) at altitude, it is concluded that neither these nor the excessive PV shifts with exercise contribute to the reduction in maximal oxygen uptake at altitude. During altitude exposure the percent loss in PV is found to follow the percent reduction in maximal oxygen uptake; however, on the first day of recovery the percent change in PV remains depressed while maximal oxygen uptake returns to control levels.
Blood Test: Basic Metabolic Panel (BMP)
... the body's fluid levels and its acid-base balance. Normal levels of these electrolytes help keep cells in the body working as they should. Blood urea nitrogen (BUN) and creatinine , which are waste products filtered ...
Blood Test: Comprehensive Metabolic Panel (CMP)
... the body's fluid levels and its acid-base balance. Normal levels of these electrolytes help keep cells in the body working as they should. Blood urea nitrogen (BUN) and creatinine , which are waste products filtered ...
... for nerves, muscles, and other body tissues to work properly. When the amount of sodium in fluids outside cells drops below normal, water moves into the cells to balance the levels. This causes the cells to swell ...
Heat transfer within a flat micro heat pipe with extra liquid
NASA Astrophysics Data System (ADS)
Sprinceana, Silviu; Mihai, Ioan
2016-12-01
In the real functioning of flat micro heat pipe (FMHP), there can appear cases when the temperature from the vaporization zone can exceed a critical value caused by a sudden increase of the thermal flow. The heat transfer which is completed conductively through the copper wall of a FMHP vaporizer causes the vaporization of the work fluid. On the condenser, the condensation of the fluid vapors and the transfer of the condenser to the vaporizer can no longer be achieved. The solution proposed for enhancing heat transfer in the event of blockage phenomenon FMHP, it is the injection of a certain amount of working fluid in the vaporization zone. By this process the working fluid injected into the evaporator passes suddenly in the vapor, producing a cooling zone. The new product additional mass of vapor will leave the vaporization zone and will condense in condensation zone, thereby supplementing the amount of condensation. Thus resumes normal operating cycle of FMHP. For the experimental measurements made for the transfer of heat through the FMHP working fluid demineralized water, they were made two micro-capillary tubes of sintered copper layer. The first was filled with 1ml of demineralized water was dropped under vacuum until the internal pressure has reached a level of 1•104Pa. The second FMHP was filled with the same amount of working fluid was used and the same capillary inner layer over which was laid a polysynthetic material that will accrue an additional amount of fluid. In this case, the internal pressure was reduced to 1•104Pa.
Control of Thermal Convection in Layered Fluids Using Magnetic fields
NASA Technical Reports Server (NTRS)
Ramachandran, N.; Leslie, F. W.
2003-01-01
Immiscible fluid layers are found in a host of applications ranging from materials processing, for example the use of encapsulants in float zone crystal growth technique and a buffer layer in industrial Czochralski growth of crystals to prevent Marangoni convection, to heat transfer phenomena in day-to-day processes like the presence of air pockets in heat exchangers. In the microgravity and space processing realm, the exploration of other planets requires the development of enabling technologies in several fronts. The reduction in the gravity level poses unique challenges for fluid handling and heat transfer applications. The present work investigates the efficacy of controlling thermal convective flow using magnetic fluids and magnetic fields. The setup is a two-layer immiscible liquids system with one of the fluids being a diluted ferrofluid (super paramagnetic nano particles dispersed in carrier fluid). Using an external magnetic field one can essentially dial in a volumetric force - gravity level, on the magnetic fluid and thereby affect the system thermo-fluid behavior. The paper will describe the experimental and numerical modeling approach to the problem and discuss results obtained to date.
Transport properties at fluids interfaces: a molecular study for a macroscopic modelling
NASA Astrophysics Data System (ADS)
Russo, Antonio; Morciano, Matteo; Sibley, David N.; Nold, Andreas; Goddard, Benjamin D.; Asinari, Pietro; Kalliadasis, Serafim
2017-11-01
Rapid developments in the field of micro- and nano-fluidics require detailed analysis of the properties of matter at the molecular level. But despite numerous works in the literature, appropriate macroscopic relations able to integrate a microscopic description of fluid and soft matter properties at liquid-vapour and multi-fluid interfaces are missing. As a consequence, studies on interfacial phenomena and micro-device designs often rely on oversimplified assumptions, e.g. that the viscosities can be considered constant across interfaces. In our work, we present non-equilibrium MD simulations to scrutinise efficiently and systematically, through the tools of statistical mechanics, the anisotropic properties of fluids, namely density variations, stress tensor, and shear viscosity, at the fluid interfaces between liquid and vapour and between two partially miscible fluids. Our analysis has led to the formulation of a general relation between shear viscosity and density variations validated for a wide spectrum of interfacial fluid problems. In addition, it provides a rational description of other interfacial quantities of interest, including surface tension and its origins, and more generally, it offers valuable insight of molecular transport phenomena at interfaces.
Assessment of the Use of Nanofluids in Spacecraft Active Thermal Control Systems
NASA Technical Reports Server (NTRS)
Ungar, Eugene K.; Erickson, Lisa R.
2011-01-01
The addition of metallic nanoparticles to a base heat transfer fluid can dramatically increase its thermal conductivity. These nanofluids have been shown to have advantages in some heat transport systems. Their enhanced properties can allow lower system volumetric flow rates and can reduce the required pumping power. Nanofluids have been suggested for use as working fluids for spacecraft Active Thermal Control Systems (ATCSs). However, there are no studies showing the end-to-end effect of nanofluids on the design and performance of spacecraft ATCSs. In the present work, a parametric study is performed to assess the use of nanofluids in a spacecraft ATCSs. The design parameters of the current Orion capsule and the tabulated thermophysical properties of nanofluids are used to assess the possible benefits of nanofluids and how their incorporation affects the overall design of a spacecraft ATCS. The study shows that the unique system and component-level design parameters of spacecraft ATCSs render them best suited for pure working fluids. The addition of nanoparticles to typical spacecraft thermal control working fluids actually results in an increase in the system mass and required pumping power.
Fluid Physics Experiments onboard International Space Station: Through the Eyes of a Scientist.
NASA Astrophysics Data System (ADS)
Shevtsova, Valentina
Fluids are present everywhere in everyday life. They are also present as fuel, in support systems or as consumable in rockets and onboard of satellites and space stations. Everyone experiences every day that fluids are very sensitive to gravity: on Earth liquids flow downwards and gases mostly rise. Nowadays much of the interest of the scientific community is on studying the phenomena at microscales in so-called microfluidic systems. However, at smaller scales the experimental investigation of convective flows becomes increasingly difficult as the control parameter Ra scales with g L (3) (g; acceleration level, L: length scale). A unique alternative to the difficulty of investigating systems with small length scale on the ground is to reduce the gravity level g. In systems with interfaces, buoyancy forces are proportional to the volume of the liquid, while capillary forces act solely on the liquid surface. The importance of buoyancy diminishes either at very small scales or with reducing the acceleration level. Under the weightless conditions of space where buoyancy is virtually eliminated, other mechanisms such as capillary forces, diffusion, vibration, shear forces, electrostatic and electromagnetic forces are dominating in the fluid behaviour. This is why research in space represents a powerful tool for scientific research in this field. Understanding how fluids work really matters and so does measuring their properties accurately. Presently, a number of scientific laboratories, as usual goes with multi-user instruments, are involved in fluid research on the ISS. The programme of fluid physics experiments on-board deals with capillary flows, diffusion, dynamics in complex fluids (foams, emulsions and granular matter), heat transfer processes with phase change, physics and physico-chemistry near or beyond the critical point and it also extends to combustion physics. The top-level objectives of fluid research in space are as follows: (i) to investigate fluid behaviour in order to support the development of predictive models for the management of fluids and fluid mixtures on the ground as well as in space; (ii) to measure fluid properties that are either very difficult or not possible at all to measure on the ground and establish benchmarks; (iii) to exploit the absence of gravity forces to study new behaviours and implement new experimental configurations; Surely, all of you have seen movies about astronauts’ work and life on the ISS. Here you will learn another approach to the ISS activity, through the opinion of experienced scientist.
Forensic discrimination of vaginal epithelia by DNA methylation analysis through pyrosequencing.
Antunes, Joana; Silva, Deborah S B S; Balamurugan, Kuppareddi; Duncan, George; Alho, Clarice S; McCord, Bruce
2016-10-01
The accurate identification of body fluids from crime scenes can aid in the discrimination between criminal and innocent intent. This research aimed to determine if the levels of DNA methylation in the locus PFN3A could be used to discriminate vaginal epithelia from other body fluids. In this work we bisulfite-modified and amplified DNA samples from blood, saliva, semen, and vaginal epithelia using primers for PFN3A. Through pyrosequencing we were able to show that vaginal epithelia present distinct methylation levels when compared to other body fluids. Mixtures of different body fluids present methylation values that correlate with single-source body fluid samples and the primers for PFN3A are specific for primates. This report successfully demonstrated that the analysis of methylation in the PFN3A locus can be used for vaginal epithelia discrimination in forensic samples. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Conceptual design of intravenous fluids level monitoring system - a review
NASA Astrophysics Data System (ADS)
Verma, Prikshit; Padmani, Aniket; Boopathi, M.
2017-11-01
In today’s world of automation, there are advancements going on in all the fields. Each work is being automated day by day. However, if we see our current medical care system, some areas require manual caretaker and are loaded with heavy jobs, which consumes a lot of time. Nevertheless, since the work is related to human health, it should be properly done and that too with accuracy. An example of such a particular work is injecting saline or Intravenous (IV) fluids in a patient. The monitoring of such fluids needs utter attention as if the bottle of the fluid is not changed on time, it may lead to various problems for the patients like backflow of blood, blood loss etc. Various researches have been performed to overcome such critical situation. Different monitoring and alerting techniques are described in different researches. So, in our study, we will go through the researches done in this particular field and will see how different ideas are implemented.
NASA Astrophysics Data System (ADS)
Lawal, S. A.; Choudhury, I. A.; Nukman, Y.
2015-01-01
The understanding of cutting fluids performance in turning process is very important in order to improve the efficiency of the process. This efficiency can be determined based on certain process parameters such as flank wear, cutting forces developed, temperature developed at the tool chip interface, surface roughness on the work piece, etc. In this study, the objective is to determine the influence of cutting fluids on flank wear during turning of AISI 4340 with coated carbide inserts. The performances of three types of cutting fluids were compared using Taguchi experimental method. The results show that palm kernel oil based cutting fluids performed better than the other two cutting fluids in reducing flank wear. Mathematical models for cutting parameters such as cutting speed, feed rate, depth of cut and cutting fluids were obtained from regression analysis using MINITAB 14 software to predict flank wear. Experiments were conducted based on the optimized values to validate the regression equations for flank wear and 5.82 % error was obtained. The optimal cutting parameters for the flank wear using S/N ratio were 160 m/min of cutting speed (level 1), 0.18 mm/rev of feed (level 1), 1.75 mm of depth of cut (level 2) and 2.97 mm2/s palm kernel oil based cutting fluid (level 3). ANOVA shows cutting speed of 85.36 %; and feed rate 4.81 %) as significant factors.
Evaluation of Reflexive Valve Logic for a Shipboard Firemain
2000-01-12
firemain valves can be used to measure flow rate [2-5]. In addition, several device-level communication technologies such as Lon Works, Modbus, Profibus ...19,20]: Continuity dp ,d(pV)_0 dt 8K (1) Where p = fluid density, lbm/ft3 (kg/m3) t = time, s V = fluid velocity, ft/s (m/s) x = location
Stawski, Robert S; Almeida, David M; Lachman, Margie E; Tun, Patricia A; Rosnick, Christopher B
2010-06-01
The authors of this study investigated whether fluid cognitive ability predicts exposure and emotional reactivity to daily stressors. A national sample of adults from the Midlife in the United States study and the National Study of Daily Experiences (N = 1,202) who had a mean age of 57 years (SD = 12; 56% women, 44% men) completed positive and negative mood reports as well as a stressor diary on 8 consecutive evenings via telephone. Participants also completed a telephone-based battery of tests measuring fluid cognitive ability. Higher levels of fluid cognitive ability were associated with greater exposure to work- and home-related overload stressors. Possessing higher levels of fluid cognitive ability was associated with smaller stressor-related increases in negative mood, primarily for interpersonal tensions and network stressors, and smaller stressor-related decreases in positive mood for interpersonal tensions. Furthermore, fluid cognitive ability was unrelated to subjective severity ratings of the stressors reported. Discussion focuses on the role of fluid cognitive ability in daily stress processes. (c) 2010 APA, all rights reserved).
Sammeta, SM; Vaka, SRK; Murthy, S. Narasimha
2009-01-01
The purpose of this project was to assess the validity of a novel “Electroporation and transcutaneous sampling (ETS)” technique for sampling cephalexin from the dermal extracellular fluid (ECF). This work also investigated the plausibility of using cephalexin levels in the dermal ECF as a surrogate for the drug level in the synovial fluid. In vitro and in vivo studies were carried out using hair less rats to assess the workability of ETS. Cephalexin (20mg/kg) was administered i.v. through tail vein and the time course of drug concentration in the plasma was determined. In the same rats, cephalexin concentration in the dermal ECF was determined by ETS and microdialysis techniques. In a separate set of rats, only intraarticular microdialysis was carried out determine the time course of cephalexin concentration in synovial fluid. The drug concentration in the dermal ECF determined by ETS and microdialysis did not differ significantly from each other and so as were the pharmacokinetic parameters. The results provide validity to the ETS technique. Further, there was a good correlation (~0.9) between synovial fluid and dermal ECF levels of cephalexin indicating that dermal ECF levels could be used as a potential surrogate for cephalexin concentration in the synovial fluid. PMID:19067398
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baldwin, Darryl Dean; Willi, Martin Leo; Fiveland, Scott Byron
2010-12-14
A segmented heat exchanger system for transferring heat energy from an exhaust fluid to a working fluid. The heat exchanger system may include a first heat exchanger for receiving incoming working fluid and the exhaust fluid. The working fluid and exhaust fluid may travel through at least a portion of the first heat exchanger in a parallel flow configuration. In addition, the heat exchanger system may include a second heat exchanger for receiving working fluid from the first heat exchanger and exhaust fluid from a third heat exchanger. The working fluid and exhaust fluid may travel through at least amore » portion of the second heat exchanger in a counter flow configuration. Furthermore, the heat exchanger system may include a third heat exchanger for receiving working fluid from the second heat exchanger and exhaust fluid from the first heat exchanger. The working fluid and exhaust fluid may travel through at least a portion of the third heat exchanger in a parallel flow configuration.« less
Heating production fluids in a wellbore
Orrego, Yamila; Jankowski, Todd A.
2016-07-12
A method for heating a production fluid in a wellbore. The method can include heating, using a packer fluid, a working fluid flowing through a first medium disposed in a first section of the wellbore, where the first medium transfers heat from the packer fluid to the working fluid. The method can also include circulating the working fluid into a second section of the wellbore through a second medium, where the second medium transfers heat from the working fluid to the production fluid. The method can further include returning the working fluid to the first section of the wellbore through the first medium.
Heat pipe with dual working fluids
NASA Technical Reports Server (NTRS)
Shlosinger, A. P. (Inventor)
1973-01-01
A heat pipe design is offered that utilizes an auxiliary working fluid. The fluid, although being less efficient than the main working fluid, remains liquid at low heat loads when the main working fluid freezes.
Stridsklev, Inger Cecilie; Schaller, Karl-Heinz; Langård, Sverre
2004-11-01
This study was undertaken to investigate the exposure to chromium (Cr) and nickel (Ni) in flux-cored wire (FCW) welders welding on stainless steel (SS). Seven FCW welders were monitored for 3 days to 1 workweek, measuring Cr and Ni in air, blood, and urine. The welders were questioned about exposure to Cr and Ni during their whole working careers, with emphasis on the week of monitoring, about the use of personal protective equipment and their smoking habits. The air concentrations were mean 200 microg/m(3) (range 2.4-2,744) for total Cr, 11.3 microg/m(3) (<0.2-151.3) for Cr(VI), and 50.4 microg/m(3) (<2.0-416.7) for Ni during the workdays for the five welders who were monitored with air measurements. The levels of Cr and Ni in biological fluids varied between different workplaces. For Cr in whole blood, plasma, and erythrocytes, the mean levels after work were 1.25 (<0.4-8.3) and 1.68 (<0.2-8.0) and 0.9 (<0.4-7.2) microg/l, respectively. For Ni most of the measurements in whole blood and plasma were below the detection limits, the mean levels after work being 0.84 (<0.8-3.3) and 0.57 microg/l (<0.4-1.7), respectively. Mean levels for Cr and Ni in the urine after work were 3.96 (0.34-40.7) and 2.50 (0.56-5.0) microg/g creatinine, respectively. Correlations between the Cr(VI) levels measured in air and the levels of total Cr in the measured biological fluids were found. The results seem to support the view that monitoring of Cr in the urine may be versatile for indirect monitoring of the Cr(VI) air level in FCW welders. The results seem to suggest that external and internal exposure to Cr and Ni in FCW welders welding SS is low in general.
Dehoff, Ryan R; Lind, Randall F; Love, Lonnie L; Peter, William H; Richardson, Bradley S
2015-02-10
A robotic, prosthetic or orthotic member includes a body formed of a solidified metallic powder. At least one working fluid cylinder is formed in the body. A piston is provided in the working fluid cylinder for pressurizing a fluid in the cylinder. At least one working fluid conduit receives the pressurized fluid from the cylinder. The body, working fluid cylinder and working fluid conduit have a unitary construction. A method of making a robotic member is also disclosed.
Factors Associated with Cognition in Adults: The Seattle Longitudinal Study
Yu, Fang; Ryan, Lindsay H.; Schaie, K. Warner; Willis, Sherry L.; Kolanowski, Ann
2010-01-01
A better understanding of factors that affect cognition could lead to improved health and greater independence for older adults. We examined the association of four modifiable factors (leisure-time physical activity, leisure-time cognitive activity, self-directed work, and hypertension) with changes in two aspects of fluid intelligence (verbal memory and inductive reasoning). Data for 626 adults collected over 14 years (three time points) were analyzed by multi-level modeling. A component of self-directed work, higher work control, was associated with better verbal memory (p < .05) and inductive reasoning (p < .01). There were no significant interactions among these factors. The findings suggest that a strong sense of control at work may be protective for fluid intelligence in adults. PMID:19606423
Visualization of various working fluids flow regimes in gravity heat pipe
NASA Astrophysics Data System (ADS)
Nemec, Patrik
Heat pipe is device working with phase changes of working fluid inside hermetically closed pipe at specific pressure. The phase changes of working fluid from fluid to vapour and vice versa help heat pipe to transport high heat flux. Amount of heat flux transferred by heat pipe, of course depends on kind of working fluid. The article deal about visualization of various working fluids flow regimes in glass gravity heat pipe by high speed camera and processes casing inside during heat pipe operation. Experiment working fluid flow visualization is performed with two glass heat pipes with different inner diameter (13 mm and 22 mm) filled with water, ethanol and fluorinert FC 72. The working fluid flow visualization explains the phenomena as a working fluid boiling, nucleation of bubbles, and vapour condensation on the wall, vapour and condensate flow interaction, flow down condensate film thickness on the wall occurred during the heat pipe operation.
Heat recovery system series arrangements
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kauffman, Justin P.; Welch, Andrew M.; Dawson, Gregory R.
The present disclosure is directed to heat recovery systems that employ two or more organic Rankine cycle (ORC) units disposed in series. According to certain embodiments, each ORC unit includes an evaporator that heats an organic working fluid, a turbine generator set that expands the working fluid to generate electricity, a condenser that cools the working fluid, and a pump that returns the working fluid to the evaporator. The heating fluid is directed through each evaporator to heat the working fluid circulating within each ORC unit, and the cooling fluid is directed through each condenser to cool the working fluidmore » circulating within each ORC unit. The heating fluid and the cooling fluid flow through the ORC units in series in the same or opposite directions.« less
Monitoring of chromium and nickel in biological fluids of grinders grinding stainless steel.
Stridsklev, Inger Cecilie; Schaller, Karl-Heinz; Langård, Sverre
2007-04-01
Stainless steel (SS) welders usually spend some of their working time grinding, to finish and smoothen the welding groove. The aim of this study was to investigate possible relations between the concentrations of nickel (Ni) and chromium (Cr) in the work atmosphere generated by grinders grinding SS, and to compare the air levels to the levels of Cr and Ni in their biological fluids. Hereby, it might be possible to identify the contribution of grinding to the levels of Cr and Ni in biological fluids in SS welders. Also the airborne levels of Cr and Ni in SS grinders were compared to corresponding levels in SS welders. The subjects examined in this study were selected among SS grinders not performing welding. Nine grinders were monitored for 1 workweek, measuring Cr and Ni in air, blood and urine. They were questioned about their exposure to Cr and Ni during their working careers. Air levels of total Cr up to 95 microg/m(3) and Ni levels up to 25 microg/m(3) were measured. Chromium(VI) (Cr(VI)) was detectable only in five air samples; the levels in the remaining samples were below the detection limit. The levels of Cr in blood and urine were also low. The levels of Ni in urine were close to those for MMA and MIG/MAG SS welders. In spite of high levels of total Cr and Ni observed in air, the levels found in biological fluids were low. The Cr levels in more than 50% of the whole blood and red cell samples and about 1/3 of the Cr-plasma levels were below the detection limits. The mean blood levels for Cr were 0.43, 0.60 and 0.35 microg/l, in whole blood, plasma and red cells, respectively. The mean levels for Cr in the urine was 1.6, 1.4 and 1.4 microg/g creatinine for the first void, just before and just after work. For Ni the mean blood levels were 0.87 microg/l in whole blood and 0.68 microg/l in plasma. The mean levels and ranges of Ni from the first void, just before and after work in urine were 3.79 microg/g creatinine, 3.39 and 4.56, respectively. The Cr concentrations found in whole blood, plasma and red cells were approximately the same as those found in the unexposed controls and among TIG SS welders, while the urinary levels were somewhat higher, but still lower than in the welders applying other welding techniques. The mean levels of Ni in the urine of grinders were higher than those of welders, except for SS welders welding the MIG/MAG-method. SS Grinding seems not to contribute significantly to the uptake of Cr, which may be explained by the fact that most of Cr in the air is present in the metallic (0-valent) or trivalent form, and hardly any as Cr(VI), and therefore hardly being taken up in the airways. The grinders' uptake of Ni seems to take place to the same extent as in SS welders.
Countercurrent direct contact heat exchange process and system
Wahl, III, Edward F.; Boucher, Frederic B.
1979-01-01
Recovery of energy from geothermal brines and other hot water sources by direct contact heat exchange with a working fluid, such as a hydrocarbon working fluid, e.g. isobutane. The process and system consists of a plurality of stages, each stage including mixing and settling units. In the first stage, hot brine and arm working fluid are intimately mixed and passed into a settler wherein the brine settles to the bottom of the settler and the hot working fluid rises to the top. The hot working fluid is passed to a heat engine or turbine to produce work and the working fluid is then recycled back into the system. The system is comprised of a series of stages each containing a settler and mixer, and wherein the working fluid and the brine flow in a countercurrent manner through the stages to recover the heat from the brine in increments and raise the temperature of the working fluid in increments.
NASA Technical Reports Server (NTRS)
Tournier, Jean-Michel; El-Genk, Mohamed S.
1995-01-01
A two-dimensional Heat Pipe Transient Analysis Model, 'HPTAM,' was developed to simulate the transient operation of fully-thawed heat pipes and the startup of heat pipes from a frozen state. The model incorporates: (a) sublimation and resolidification of working fluid; (b) melting and freezing of the working fluid in the porous wick; (c) evaporation of thawed working fluid and condensation as a thin liquid film on a frozen substrate; (d) free-molecule, transition, and continuum vapor flow regimes, using the Dusty Gas Model; (e) liquid flow and heat transfer in the porous wick; and (f) thermal and hydrodynamic couplings of phases at their respective interfaces. HPTAM predicts the radius of curvature of the liquid meniscus at the liquid-vapor interface and the radial location of the working fluid level (liquid or solid) in the wick. It also includes the transverse momentum jump condition (capillary relationship of Pascal) at the liquid-vapor interface and geometrically relates the radius of curvature of the liquid meniscus to the volume fraction of vapor in the wick. The present model predicts the capillary limit and partial liquid recess (dryout) in the evaporator wick, and incorporates a liquid pooling submodel, which simulates accumulation of the excess liquid in the vapor core at the condenser end.
NASA Astrophysics Data System (ADS)
Woodland, Brandon Jay
An organic Rankine cycle (ORC) is a thermodynamic cycle that is well-suited for waste heat recovery. It is generally employed for waste heat with temperatures in the range of 80 °C -- 300 °C. When the application is strictly to convert waste heat into work, thermal efficiency is not recommended as a key performance metric. In such an application, maximization of the net power output should be the objective rather than maximization of the thermal efficiency. Two alternative cycle configurations that can increase the net power produced from a heat source with a given temperature and flow rate are proposed and analyzed. These cycle configurations are 1) an ORC with two-phase flash expansion and 2) an ORC with a zeotropic working fluid mixture (ZRC). A design-stage ORC model is presented for consistent comparison of multiple ORC configurations. The finite capacity of the heat source and heat sink fluids is a key consideration in this model. Of all working fluids studied for the baseline ORC, R134a and R245fa yield the highest net power output from a given heat source. Results of the design-stage model indicate that the ORC with two-phase flash expansion offers the most improvement over the baseline ORC. However, the level of improvement that could be achieved in practice is highly uncertain due to the requirement of highly efficient two-phase expansion. The ZRC shows improvement over the baseline as long as the condenser fan power requirement is not negligible. At the highest estimated condenser fan power, the ZRC shows the most improvement, while the ORC with flash expansion is no longer beneficial. The ZRC was selected for detailed study because it does not require two-phase expansion. An experimental test rig was used to evaluate baseline ORC performance with R134a and with R245fa. The ZRC was tested on the same rig with a mixture of 62.5% R134a and 37.5% R245fa. The tested expander is a minimally-modified, of-the-shelf automotive scroll compressor. The high performance to cost ratio of this machine lends significant credence to the economic viability of small-scale, low-temperature ORCs. The experimental campaign covered two heat source temperatures, the full range of pump and expander speeds, a full range of heat source and heat sink fluid flow rates, and various charge levels for the three working fluids. This resulted in 366 steady-state measurements. The steady state measurements are used to develop a detailed ORC model. The model is based on multi-fluid performance maps for the pump and expander and a robust moving-boundary heat exchanger model. It is validated against the measured data and predicts the net power output of the tested ORC with a mean absolute percent error of 7.16%. Comparisons made with the detailed model confirm the predictions of the design-stage model. Using a conservative estimate of the condenser fan power, 19.1% improvement of the ZRC over the baseline ORC is indicated for a source temperature of 80 °C. For a 100 °C source temperature, 13.8% improvement is indicated. A key feature of the detailed ORC model is that it calculates the charge inventory of the working fluid in each heat exchanger and line set. Total system charge can also be specified as a model input. The model can represent the total charge well for R134a at low measured charge levels. As the measured charge level increases, the model becomes less accurate. Reasons for the deviation of the model at higher charge are investigated. It is expected that a charge tuning scheme could be employed to improve the accuracy of model-predicted charge.
Working memory capacity and fluid abilities: the more difficult the item, the more more is better.
Little, Daniel R; Lewandowsky, Stephan; Craig, Stewart
2014-01-01
The relationship between fluid intelligence and working memory is of fundamental importance to understanding how capacity-limited structures such as working memory interact with inference abilities to determine intelligent behavior. Recent evidence has suggested that the relationship between a fluid abilities test, Raven's Progressive Matrices, and working memory capacity (WMC) may be invariant across difficulty levels of the Raven's items. We show that this invariance can only be observed if the overall correlation between Raven's and WMC is low. Simulations of Raven's performance revealed that as the overall correlation between Raven's and WMC increases, the item-wise point bi-serial correlations involving WMC are no longer constant but increase considerably with item difficulty. The simulation results were confirmed by two studies that used a composite measure of WMC, which yielded a higher correlation between WMC and Raven's than reported in previous studies. As expected, with the higher overall correlation, there was a significant positive relationship between Raven's item difficulty and the extent of the item-wise correlation with WMC.
Fluid replacement advice during work in fully encapsulated impermeable chemical protective suits.
Rubenstein, Candace D; DenHartog, Emiel A; Deaton, A Shawn; Bogerd, Cornelis P; DeKant, Saskia
2017-06-01
A major concern for responders to hazardous materials (HazMat) incidents is the heat strain that is caused by fully encapsulated impermeable chemical protective suits. In a research project, funded by the US Department of Defense, the thermal strain experienced when wearing these suits was studied. One particular area of interest was the fluid loss of responders during work in these suits as dehydration may be an additional health concern to the heat strain. 17 City of Raleigh firemen and 24 students were tested at two different labs. Subjects between the ages of 25 and 51 were used for human subject trials in a protocol approved by the local ethical committee. Six different Level A HazMat suits were evaluated in three climates: moderate (24°C, 50% RH, 20°C WBGT), warm-wet (32°C, 60% RH, 30°C WBGT), and hot-dry (45°C, 20% RH, 37°C WBGT, 200 W/m 2 radiant load) and at three walking speeds: 2.5 km/hr, 4 km/hr, and 5.5 km/hr. 4 km/hr was tested in all three climates and the other two walking speeds were tested in the moderate climate. Weight loss data was collected to determine fluid loss during these experiments. Working time ranged from as low as 20 min in the hot-dry condition to 60 min (the maximum) in the moderate climate, especially common at the lowest walking speed. The overall results from all experiments showed that fluid loss ranged from 0.2-2.2 L during these exposures, with the average fluid loss being 0.8 L, with 56% of the data between 0.5 L and 1 L of fluid loss. Further analysis showed that a suggestion of drinking 0.7 Liter per hour would safely hydrate over 50% of responders after one work-rest cycle. Applying this fluid volume over three work-rest cycles only put 11% of responders at risk of hypohydration vs. the 57% at risk with no fluid intake.
Klimkiewicz-Blok, Dominika; Florjański, Jerzy; Zalewski, Jerzy; Blok, Radosław
2012-01-01
Little is known about the behavior of interleukin 15 (IL-15) and 18 (IL-18) in the amniotic fluid in the second trimester of gestations complicated by chromosomal defects in the fetus. Likewise, it has not yet been established whether a fetus with chromosome abnormalities creates its immunity mechanisms in the same way as a fetus with a normal karyotype. The aim of this work was to assess the concentration of IL-15 and IL-18 in the amniotic fluid in the second trimester of gestation in fetuses with normal karyotypes and with chromosome abnormalities. The material consisted of 51 samples of amniotic fluid obtained from genetic amniocenteses carried out between the 15th and the 19th weeks of gestation. On the basis of cytogenetic screening, two groups were singled out: Group I--45 fetuses with normal karyotypes, and Group II--6 fetuses with abnormal karyotypes. The concentrations of IL-15 and IL-18 in the amniotic fluid were assessed with ready-made assays and analyzed, and the results from both groups were compared. The differences between the IL-15 levels in the amniotic fluid from Groups I and II proved to be statistically insignificant (p = 0.054). However, the average IL-18 levels in the amniotic fluid of the fetuses with normal karyotypes were significantly higher than in the amniotic fluid of the fetuses with chromosome abnormalities (p = 0.032). Some defense mechanisms in the second trimester of gestation in fetuses with chromosome abnormalities may develop in a different way than in fetuses with normal karyotypes.
ScienceCast 125: Genius Materials on the ISS
2013-11-25
Researchers working with magnetic fluids on the International Space Station are taking "smart materials" to the next level. With proper coaxing, molecules can assemble themselves into "genius materials" with surprising properties.
The Making of a Filmmaker: Curating Learning Identities in Early Careers
ERIC Educational Resources Information Center
Gilje, Øystein; Groeng, Linn M.
2015-01-01
As the work with moving images has become digitized, the availability and affordability of filmmaking has facilitated new forms of creative content production in various genres and contexts. On an institutional level, the creative and cultural sector of work is increasingly characterized by more fluid organizational structures, which include…
F*** Yeah Fluid Dynamics: Lessons from online outreach
NASA Astrophysics Data System (ADS)
Sharp, Nicole
2013-11-01
The fluid dynamics education outreach blog FYFD features photos, videos, and research along with concise, accessible explanations of phenomena every weekday. Over the past three years, the blog has attracted an audience of roughly 200,000 online followers. Reader survey results indicate that over half of the blog's audience works or studies in non-fluids fields. Twenty-nine percent of all survey respondents indicate that FYFD has been a positive influence on their desire to pursue fluid dynamics in their education or career. Of these positively influenced readers, over two-thirds have high-school or undergraduate-level education, indicating a significant audience of potential future fluid dynamicists. This talk will utilize a mixture of reader metrics, web analytics, and anecdotal evidence to discuss what makes science outreach successful and how we, as a community, can benefit from promoting fluid dynamics to a wider audience. http://tinyurl.com/azjjgj2
Hydrocarbon fluid, ejector refrigeration system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kowalski, G.J.; Foster, A.R.
1993-08-31
A refrigeration system is described comprising: a vapor ejector cycle including a working fluid having a property such that entropy of the working fluid when in a saturated vapor state decreases as pressure decreases, the vapor ejector cycle comprising: a condenser located on a common fluid flow path; a diverter located downstream from the condenser for diverting the working fluid into a primary fluid flow path and a secondary fluid flow path parallel to the primary fluid flow path; an evaporator located on the secondary fluid flow path; an expansion device located on the secondary fluid flow path upstream ofmore » the evaporator; a boiler located on the primary fluid flow path parallel to the evaporator for boiling the working fluid, the boiler comprising an axially extending core region having a substantially constant cross sectional area and a porous capillary region surrounding the core region, the core region extending a length sufficient to produce a near sonic velocity saturated vapor; and an ejector having an outlet in fluid communication with the inlet of the condenser and an inlet in fluid communication with the outlet of the evaporator and the outlet of the boiler and in which the flows of the working fluid from the evaporator and the boiler are mixed and the pressure of the working fluid is increased to at least the pressure of the condenser, the ejector inlet, located downstream from the axially extending core region, including a primary nozzle located sufficiently close to the outlet of the boiler to minimize a pressure drop between the boiler and the primary nozzle, the primary nozzle of the ejector including a converging section having an included angle and length preselected to receive the working fluid from the boiler as a near sonic velocity saturated vapor.« less
Properties of forced convection experimental with silicon carbide based nano-fluids
NASA Astrophysics Data System (ADS)
Soanker, Abhinay
With the advent of nanotechnology, many fields of Engineering and Science took a leap to the next level of advancements. The broad scope of nanotechnology initiated many studies of heat transfer and thermal engineering. Nano-fluids are one such technology and can be thought of as engineered colloidal fluids with nano-sized colloidal particles. There are different types of nano-fluids based on the colloidal particle and base fluids. Nano-fluids can primarily be categorized into metallic, ceramics, oxide, magnetic and carbon based. The present work is a part of investigation of the thermal and rheological properties of ceramic based nano-fluids. alpha-Silicon Carbide based nano-fluid with Ethylene Glycol and water mixture 50-50% volume concentration was used as the base fluid here. This work is divided into three parts; Theoretical modelling of effective thermal conductivity (ETC) of colloidal fluids, study of Thermal and Rheological properties of alpha-SiC nano-fluids, and determining the Heat Transfer properties of alpha-SiC nano-fluids. In the first part of this work, a theoretical model for effective thermal conductivity (ETC) of static based colloidal fluids was formulated based on the particle size, shape (spherical), thermal conductivity of base fluid and that of the colloidal particle, along with the particle distribution pattern in the fluid. A MATLAB program is generated to calculate the details of this model. The model is specifically derived for least and maximum ETC enhancement possible and thereby the lower and upper bounds was determined. In addition, ETC is also calculated for uniform colloidal distribution pattern. Effect of volume concentration on ETC was studied. No effect of particle size was observed for particle sizes below a certain value. Results of this model were compared with Wiener bounds and Hashin- Shtrikman bounds. The second part of this work is a study of thermal and rheological properties of alpha-Silicon Carbide based nano-fluids. The nano-fluid properties were tested at three different volume concentrations; 0.55%, 1% and 1.6%. Thermal conductivity was measured for the three-volume concentration as function of temperature. Thermal conductivity enhancement increased with the temperature and may be attributed to increased Brownian motion of colloidal particles at higher temperatures. Measured thermal conductivity values are compared with results obtained by theoretical model derived in this work. Effect of temperature and volume concentration on viscosity was also measured and reported. Viscosity increase and related consequences are important issues for the use of nano-fluids. Extensive measurements of heat transfer and pressure drop for forced convection in circular pipes with nano-fluids was also conducted. Parameters such as heat transfer coefficient, Nusselt number, pressure drop and a thermal hydraulic performance factor that takes into account the gains made by increase in thermal conductivity as well as penalties related to increase in pressure drop are evaluated for laminar and transition flow regimes. No significant improvement in heat transfer (Nusselt number) compared to its based fluid was observed. It is also observed that the values evaluated for the thermal-hydraulic performance factor (change in heat transfer/change in pressure drop) was under unity for many flow conditions indicating poor overall applicability of SiC based nano-fluids.
Do the Effects of Working Memory Training Depend on Baseline Ability Level?
ERIC Educational Resources Information Center
Foster, Jeffrey L.; Harrison, Tyler L.; Hicks, Kenny L.; Draheim, Christopher; Redick, Thomas S.; Engle, Randall W.
2017-01-01
There is a debate about the ability to improve cognitive abilities such as fluid intelligence through training on tasks of working memory capacity. The question addressed in the research presented here is who benefits the most from training: people with low cognitive ability or people with high cognitive ability? Subjects with high and low working…
Method and apparatus for removing non-condensible gas from a working fluid in a binary power system
Mohr, Charles M.; Mines, Gregory L.; Bloomfield, K. Kit
2002-01-01
Apparatus for removing non-condensible gas from a working fluid utilized in a thermodynamic system comprises a membrane having an upstream side operatively connected to the thermodynamic system so that the upstream side of the membrane receives a portion of the working fluid. The first membrane separates the non-condensible gas from the working fluid. A pump operatively associated with the membrane causes the portion of the working fluid to contact the membrane and to be returned to the thermodynamic system.
Consideration of Alternate Working Fluid Properties in Gas Lubricated Foil Journal Bearings
NASA Technical Reports Server (NTRS)
Smith, Matthew J.
2004-01-01
The Oil-Free Turbomachinery Program at the NASA Glenn Research center is committed to, revolutionary improvements in performance, efficiency and reliability of turbomachinery propulsion systems. One of the key breakthroughs by which this goal is being achieved is the maturation of air lubricated foil bearing technology. Through experimental testing, foil bearings have demonstrated a variety of exceptional qualities that show them to have an important role in the future of rotordynamic lubrication. Most of the work done with foil bearings thus far has considered ambient air at atmospheric pressure as the working fluid or lubricating fluid in the bearing. However, special applications of oil-free technology require the use of air at non- standard ambient conditions or completely different working fluids altogether. The NASA Jupiter Icy Moon Orbiter program presents power generation needs far beyond that of any previous space exploration effort. The proposed spacecraft will require significant power generation to provide the propulsion necessary to reach the moons of Jupiter and navigate between them. Once there, extensive scientific research will be conducted that will also present significant power requirements. Such extreme needs require exploring a new method for power generation in space. A proposed solution involves a Brayton cycle nuclear fission reactor. The nature of this application requires reliable performance of all reactor components for many years of operation under demanding conditions. This includes the bearings which will be operating with an alternative working fluid that is a combination of Helium and Xenon gases commonly known as HeXe. This fluid has transport and thermal properties that vary significantly from that of air and the effect of these property differences on bearing performance must be considered. One of the most promising applications of oil-free technology is in aircraft turbine engines. Eliminating the oil supply systems from aircraft engines will lead to significant weight and maintenance reduction. In such applications, the lubricating fluid will be high altitude air. This air will be at much lower pressure than that at sea level. Again this property change will result in a change in bearing performance, and analysis is required to quantify this effect. The study of these alternate working fluid properties will be conducted in two ways: analytically and experimentally. Analytical research will include the use of a mathematical code that can predict film thickness profiles for various ambient conditions. Estimations of load capacity can be made based upon the film thickness trends. These values will then be compared to those obtained from classical rigid bearing analysis. Experimental Research will include testing a foil bearing at a variety of ambient air pressures. The analytical and experimental data will be compared to draw conclusions on bearing performance under alternate working fluid properties.
Evaluation of Working Fluids for Organic Rankine Cycle Based on Exergy Analysis
NASA Astrophysics Data System (ADS)
Setiawan, D.; Subrata, I. D. M.; Purwanto, Y. A.; Tambunan, A. H.
2018-05-01
One of the crucial aspects to determine the performance of Organic Rankine Cycle (ORC) is the selection of appropriate working fluids. This paper describes the simulative performance of several organic fluid and water as working fluid of an ORC based on exergy analysis with a heat source from waste heat recovery. The simulation was conducted by using Engineering Equation Solver (EES). The effect of several parameters and thermodynamic properties of working fluid was analyzed, and part of them was used as variables for the simulation in order to determine their sensitivity to the exergy efficiency changes. The results of this study showed that water is not appropriate to be used as working fluid at temperature lower than 130 °C, because the expansion process falls in saturated area. It was also found that Benzene had the highest exergy efficiency, i.e. about 10.49%, among the dry type working fluid. The increasing turbine inlet temperature did not lead to the increase of exergy efficiency when using organic working fluids with critical temperature near heat source temperature. Meanwhile, exergy efficiency decreasing linearly with the increasing condenser inlet temperature. In addition, it was found that working fluid with high latent heat of vaporization and specific heat exert in high exergy efficiency.
Apparatus for moving a pipe inspection probe through piping
Zollinger, W.T.; Appel, D.K.; Lewis, G.W.
1995-07-18
A method and apparatus are disclosed for controllably moving devices for cleaning or inspection through piping systems, including piping systems with numerous piping bends therein, by using hydrostatic pressure of a working fluid introduced into the piping system. The apparatus comprises a reservoir or other source for supplying the working fluid to the piping system, a launch tube for admitting the device into the launcher and a reversible, positive displacement pump for controlling the direction and flow rate of the working fluid. The device introduced into the piping system moves with the flow of the working fluid through the piping system. The launcher attaches to the valved ends of a piping system so that fluids in the piping system can recirculate in a closed loop. The method comprises attaching the launcher to the piping system, supplying the launcher with working fluid, admitting the device into the launcher, pumping the working fluid in the direction and at the rate desired so that the device moves through the piping system for pipe cleaning or inspection, removing the device from the launcher, and collecting the working fluid contained in the launcher. 8 figs.
Apparatus for moving a pipe inspection probe through piping
Zollinger, W. Thor; Appel, D. Keith; Lewis, Gregory W.
1995-01-01
A method and apparatus for controllably moving devices for cleaning or inspection through piping systems, including piping systems with numerous piping bends therein, by using hydrostatic pressure of a working fluid introduced into the piping system. The apparatus comprises a reservoir or other source for supplying the working fluid to the piping system, a launch tube for admitting the device into the launcher and a reversible, positive displacement pump for controlling the direction and flow rate of the working fluid. The device introduced into the piping system moves with the flow of the working fluid through the piping system. The launcher attaches to the valved ends of a piping system so that fluids in the piping system can recirculate in a closed loop. The method comprises attaching the launcher to the piping system, supplying the launcher with working fluid, admitting the device into the launcher, pumping the working fluid in the direction and at the rate desired so that the device moves through the piping system for pipe cleaning or inspection, removing the device from the launcher, and collecting the working fluid contained in the launcher.
Joyce, T J; Yood, R A; Carraway, R E
1993-09-01
Substance-P (SP) and its metabolites, SP-(1-7) and SP-(5-11), were quantitated in arthritic synovial fluids and plasma using a validated procedure. This process involved collection into appropriate enzyme inhibitors, extraction with acid-acetone, high pressure liquid chromatography, and RIA using region-specific antisera. Our results demonstrate that the levels of authentic SP in these fluids are less than 3.5 pmol/L, which is 50- to 10,000-fold less than those previously reported by others. These discrepant findings were not attributable to degradation, because added SP was recovered in good yield, and the measured levels of the metabolites SP-(1-7) and SP-(5-11) were also extremely low. In search of an explanation, we noted that many of the earlier reports involved direct assay of these fluids (without extraction and chromatography). Further work indicated that proteolytic enzymes (e.g. protease 24.11) present in these unextracted fluids can give rise to artifactually high SP measurements. We conclude that if SP is released within the joint space and if it participates in the inflammatory reaction and/or healing process, it most likely does so in a local fashion, which would not involve its accumulation in synovial fluid or plasma.
Thermodynamic properties of non-conformal soft-sphere fluids with effective hard-sphere diameters.
Rodríguez-López, Tonalli; del Río, Fernando
2012-01-28
In this work we study a set of soft-sphere systems characterised by a well-defined variation of their softness. These systems represent an extension of the repulsive Lennard-Jones potential widely used in statistical mechanics of fluids. This type of soft spheres is of interest because they represent quite accurately the effective intermolecular repulsion in fluid substances and also because they exhibit interesting properties. The thermodynamics of the soft-sphere fluids is obtained via an effective hard-sphere diameter approach that leads to a compact and accurate equation of state. The virial coefficients of soft spheres are shown to follow quite simple relationships that are incorporated into the equation of state. The approach followed exhibits the rescaling of the density that produces a unique equation for all systems and temperatures. The scaling is carried through to the level of the structure of the fluids.
Jaques, Peter A; Gao, Pengfei; Kilinc-Balci, Selcen; Portnoff, Lee; Weible, Robyn; Horvatin, Matthew; Strauch, Amanda; Shaffer, Ronald
2016-11-01
Gowns and coveralls are important components of protective ensembles used during the management of known or suspected Ebola patients. In this study, an Elbow Lean Test was used to obtain a visual semi-quantitative measure of the resistance of medical protective garments to the penetration of two bodily fluid simulants. Tests were done on swatches of continuous and discontinuous regions of fabrics cut from five gowns and four coveralls at multiple elbow pressure levels (2-44 PSI). Swatches cut from the continuous regions of one gown and two coveralls did not have any strike-through. For discontinuous regions, only the same gown consistently resisted fluid strike-through. As hypothesized, with the exception of one garment, fluid strike-through increased with higher applied elbow pressure, was higher for lower fluid surface tension, and was higher for the discontinuous regions of the protective garments.
Self-compensating tensiometer and method
Hubbell, Joel M.; Sisson, James B.
2003-01-01
A pressure self-compensating tensiometer and method to in situ determine below grade soil moisture potential of earthen soil independent of changes in the volume of water contained within the tensiometer chamber, comprising a body having first and second ends, a porous material defining the first body end, a liquid within the body, a transducer housing submerged in the liquid such that a transducer sensor within the housing is kept below the working fluid level in the tensiometer and in fluid contact with the liquid and the ambient atmosphere.
NASA Astrophysics Data System (ADS)
Camus, E.; Elizalde, J. D.; Morata, D.; Wechsler, C.
2017-12-01
In geothermal systems alteration minerals are evidence of hot fluid flow, being present even in absence of other surface manifestations. Because these minerals result from the interaction between geothermal fluids and surrounding host rocks, they will provide information about features of thermal fluids as temperature, composition and pH, allowing tracking their changes and evolution. In this work, we study the Licancura Geothermal field located in the Andean Cordillera in Northern Chile. The combination of Principal Components Analysis on ASTER-L1T imagery and X Ray Diffraction (XRD) allow us to interpret fluid conditions and the areas where fluid flow took place. Results from red, green, blue color composite imagery show the presence of three types of secondary paragenesis. The first one corresponds to hematite and goethite, mainly at the east of the area, in the zone of eroded Pliocene volcanic edifices. The second one, mainly at the center of the area, highlighting propylitic alteration, includes minerals such as chlorite, illite, calcite, zeolites, and epidote. The third paragenesis, spatially related to the intersection between faults, represents advanced argillic alteration, includes minerals as alunite, kaolinite, and jarosite. XRD analysis support results from remote sensing techniques. These results suggest an acid pH hydrothermal fluid reaching temperatures at surface up to 80-100°C, which used faults as a conduit, originating advanced argillic minerals. The same fluid was, probably, responsible for propylitic paragenesis. However, iron oxides paragenesis identified in the area of eroded volcanoes probably corresponds to other processes associated with weathering rather than geothermal activity. In this work, we propose the applicability of remote sensing techniques as a first level exploration tool useful for high-altitude geothermal fields. Detailed clay mineral studies (XRD and SEM) would allow us to a better characterization of the geothermal fluid flow and the defining fluid pathways in the Licancura geothermal field. This work is a contribution to the FONDAP-CONICYT 15090013 Project. E.C. thanks CONICYT for her Ph.D. grant.
Rankine cycle condenser pressure control using an energy conversion device bypass valve
Ernst, Timothy C; Nelson, Christopher R; Zigan, James A
2014-04-01
The disclosure provides a waste heat recovery system and method in which pressure in a Rankine cycle (RC) system of the WHR system is regulated by diverting working fluid from entering an inlet of an energy conversion device of the RC system. In the system, an inlet of a controllable bypass valve is fluidly coupled to a working fluid path upstream of an energy conversion device of the RC system, and an outlet of the bypass valve is fluidly coupled to the working fluid path upstream of the condenser of the RC system such that working fluid passing through the bypass valve bypasses the energy conversion device and increases the pressure in a condenser. A controller determines the temperature and pressure of the working fluid and controls the bypass valve to regulate pressure in the condenser.
McBride, Donald D.; Bua, Dominic; Domankevitz, Yacov; Nishioka, Norman
1998-01-01
A debris removal system removes debris from a work site by flowing fluid away from the work site toward the periphery of a structure. The fluid flow can be kept constant around the periphery so that debris is removed evenly. The structure can have a reduced cross section between the fluid inlet and the work site so that the resulting increased fluid velocity works to prevent debris from escaping.
McBride, D.D.; Bua, D.; Domankevitz, Y.; Nishioka, N.
1998-06-23
A debris removal system removes debris from a work site by flowing fluid away from the work site toward the periphery of a structure. The fluid flow can be kept constant around the periphery so that debris is removed evenly. The structure can have a reduced cross section between the fluid inlet and the work site so that the resulting increased fluid velocity works to prevent debris from escaping. 9 figs.
Rapid microfluidic thermal cycler for nucleic acid amplification
Beer, Neil Reginald; Vafai, Kambiz
2015-10-27
A system for thermal cycling a material to be thermal cycled including a microfluidic heat exchanger; a porous medium in the microfluidic heat exchanger; a microfluidic thermal cycling chamber containing the material to be thermal cycled, the microfluidic thermal cycling chamber operatively connected to the microfluidic heat exchanger; a working fluid at first temperature; a first system for transmitting the working fluid at first temperature to the microfluidic heat exchanger; a working fluid at a second temperature, a second system for transmitting the working fluid at second temperature to the microfluidic heat exchanger; a pump for flowing the working fluid at the first temperature from the first system to the microfluidic heat exchanger and through the porous medium; and flowing the working fluid at the second temperature from the second system to the heat exchanger and through the porous medium.
Steinsvåg, Kjersti; Galea, Karen S; Krüger, Kirsti; Peikli, Vegard; Sánchez-Jiménez, Araceli; Sætvedt, Esther; Searl, Alison; Cherrie, John W; van Tongeren, Martie
2011-05-01
Workers in the drilling section of the offshore petroleum industry are exposed to air pollutants generated by drilling fluids. Oil mist and oil vapour concentrations have been measured in the drilling fluid processing areas for decades; however, little work has been carried out to investigate exposure determinants such as drilling fluid viscosity and temperature. A study was undertaken to investigate the effect of two different oil-based drilling fluid systems and their temperature on oil mist, oil vapour, and total volatile organic compounds (TVOC) levels in a simulated shale shaker room at a purpose-built test centre. Oil mist and oil vapour concentrations were sampled simultaneously using a sampling arrangement consisting of a Millipore closed cassette loaded with glass fibre and cellulose acetate filters attached to a backup charcoal tube. TVOCs were measured by a PhoCheck photo-ionization detector direct reading instrument. Concentrations of oil mist, oil vapour, and TVOC in the atmosphere surrounding the shale shaker were assessed during three separate test periods. Two oil-based drilling fluids, denoted 'System 2.0' and 'System 3.5', containing base oils with a viscosity of 2.0 and 3.3-3.7 mm(2) s(-1) at 40°C, respectively, were used at temperatures ranging from 40 to 75°C. In general, the System 2.0 yielded low oil mist levels, but high oil vapour concentrations, while the opposite was found for the System 3.5. Statistical significant differences between the drilling fluid systems were found for oil mist (P = 0.025),vapour (P < 0.001), and TVOC (P = 0.011). Increasing temperature increased the oil mist, oil vapour, and TVOC levels. Oil vapour levels at the test facility exceeded the Norwegian oil vapour occupational exposure limit (OEL) of 30 mg m(-3) when the drilling fluid temperature was ≥50°C. The practice of testing compliance of oil vapour exposure from drilling fluids systems containing base oils with viscosity of ≤2.0 mm(2) s(-1) at 40°C against the Norwegian oil vapour OEL is questioned since these base oils are very similar to white spirit. To reduce exposures, relevant technical control measures in this area are to cool the drilling fluid <50°C before it enters the shale shaker units, enclose shale shakers and related equipment, in addition to careful consideration of which fluid system to use.
Gonthier, Corentin; Thomassin, Noémylle
2015-10-01
Working memory capacity consistently correlates with fluid intelligence. It has been suggested that this relationship is partly attributable to strategy use: Participants with high working memory capacity would use more effective strategies, in turn leading to higher performance on fluid intelligence tasks. However, this idea has never been directly investigated. In 2 experiments, we tested this hypothesis by directly manipulating strategy use in a combined experimental-correlational approach (Experiment 1; N = 250) and by measuring strategy use with a self-report questionnaire (Experiment 2; N = 93). Inducing all participants to use an effective strategy in Raven's matrices decreased the correlation between working memory capacity and performance; the strategy use measure fully mediated the relationship between working memory capacity and performance on the matrices task. These findings indicate that individual differences in strategic behavior drive the predictive utility of working memory. We interpret the results within a theoretical framework integrating the multiple mediators of the relationship between working memory capacity and high-level cognition. (c) 2015 APA, all rights reserved).
Cascaded organic rankine cycles for waste heat utilization
Radcliff, Thomas D [Vernon, CT; Biederman, Bruce P [West Hartford, CT; Brasz, Joost J [Fayetteville, NY
2011-05-17
A pair of organic Rankine cycle systems (20, 25) are combined and their respective organic working fluids are chosen such that the organic working fluid of the first organic Rankine cycle is condensed at a condensation temperature that is well above the boiling point of the organic working fluid of the second organic Rankine style system, and a single common heat exchanger (23) is used for both the condenser of the first organic Rankine cycle system and the evaporator of the second organic Rankine cycle system. A preferred organic working fluid of the first system is toluene and that of the second organic working fluid is R245fa.
Rankine cycle load limiting through use of a recuperator bypass
Ernst, Timothy C.
2011-08-16
A system for converting heat from an engine into work includes a boiler coupled to a heat source for transferring heat to a working fluid, a turbine that transforms the heat into work, a condenser that transforms the working fluid into liquid, a recuperator with one flow path that routes working fluid from the turbine to the condenser, and another flow path that routes liquid working fluid from the condenser to the boiler, the recuperator being configured to transfer heat to the liquid working fluid, and a bypass valve in parallel with the second flow path. The bypass valve is movable between a closed position, permitting flow through the second flow path and an opened position, under high engine load conditions, bypassing the second flow path.
Salomons, Erik M.; Lohman, Walter J. A.; Zhou, Han
2016-01-01
Propagation of sound waves in air can be considered as a special case of fluid dynamics. Consequently, the lattice Boltzmann method (LBM) for fluid flow can be used for simulating sound propagation. In this article application of the LBM to sound propagation is illustrated for various cases: free-field propagation, propagation over porous and non-porous ground, propagation over a noise barrier, and propagation in an atmosphere with wind. LBM results are compared with solutions of the equations of acoustics. It is found that the LBM works well for sound waves, but dissipation of sound waves with the LBM is generally much larger than real dissipation of sound waves in air. To circumvent this problem it is proposed here to use the LBM for assessing the excess sound level, i.e. the difference between the sound level and the free-field sound level. The effect of dissipation on the excess sound level is much smaller than the effect on the sound level, so the LBM can be used to estimate the excess sound level for a non-dissipative atmosphere, which is a useful quantity in atmospheric acoustics. To reduce dissipation in an LBM simulation two approaches are considered: i) reduction of the kinematic viscosity and ii) reduction of the lattice spacing. PMID:26789631
Salomons, Erik M; Lohman, Walter J A; Zhou, Han
2016-01-01
Propagation of sound waves in air can be considered as a special case of fluid dynamics. Consequently, the lattice Boltzmann method (LBM) for fluid flow can be used for simulating sound propagation. In this article application of the LBM to sound propagation is illustrated for various cases: free-field propagation, propagation over porous and non-porous ground, propagation over a noise barrier, and propagation in an atmosphere with wind. LBM results are compared with solutions of the equations of acoustics. It is found that the LBM works well for sound waves, but dissipation of sound waves with the LBM is generally much larger than real dissipation of sound waves in air. To circumvent this problem it is proposed here to use the LBM for assessing the excess sound level, i.e. the difference between the sound level and the free-field sound level. The effect of dissipation on the excess sound level is much smaller than the effect on the sound level, so the LBM can be used to estimate the excess sound level for a non-dissipative atmosphere, which is a useful quantity in atmospheric acoustics. To reduce dissipation in an LBM simulation two approaches are considered: i) reduction of the kinematic viscosity and ii) reduction of the lattice spacing.
CT findings of a unicameral calcaneal bone cyst containing a fluid-fluid level.
Gallagher, Thomas A; Lim-Dunham, Jennifer E; Vade, Aruna
2007-03-01
Calcaneal unicameral bone cysts often contain fluid, but rarely contain fluid-fluid levels. We present a case focusing on the CT findings of a large calcaneal bone cyst with a fluid-fluid level and a review of the literature.
Monodisperse granular flows in viscous dispersions in a centrifugal acceleration field
NASA Astrophysics Data System (ADS)
Cabrera, Miguel Angel; Wu, Wei
2016-04-01
Granular flows are encountered in geophysical flows and innumerable industrial applications with particulate materials. When mixed with a fluid, a complex network of interactions between the particle- and fluid-phase develops, resulting in a compound material with a yet unclear physical behaviour. In the study of granular suspensions mixed with a viscous dispersion, the scaling of the stress-strain characteristics of the fluid phase needs to account for the level of inertia developed in experiments. However, the required model dimensions and amount of material becomes a main limitation for their study. In recent years, centrifuge modelling has been presented as an alternative for the study of particle-fluid flows in a reduced scaled model in an augmented acceleration field. By formulating simple scaling principles proportional to the equivalent acceleration Ng in the model, the resultant flows share many similarities with field events. In this work we study the scaling principles of the fluid phase and its effects on the flow of granular suspensions. We focus on the dense flow of a monodisperse granular suspension mixed with a viscous fluid phase, flowing down an inclined plane and being driven by a centrifugal acceleration field. The scaled model allows the continuous monitoring of the flow heights, velocity fields, basal pressure and mass flow rates at different Ng levels. The experiments successfully identify the effects of scaling the plastic viscosity of the fluid phase, its relation with the deposition of particles over the inclined plane, and allows formulating a discussion on the suitability of simulating particle-fluid flows in a centrifugal acceleration field.
Theories of binary fluid mixtures: from phase-separation kinetics to active emulsions
NASA Astrophysics Data System (ADS)
Cates, Michael E.; Tjhung, Elsen
2018-02-01
Binary fluid mixtures are examples of complex fluids whose microstructure and flow are strongly coupled. For pairs of simple fluids, the microstructure consists of droplets or bicontinuous demixed domains and the physics is controlled by the interfaces between these domains. At continuum level, the structure is defined by a composition field whose gradients which are steep near interfaces drive its diffusive current. These gradients also cause thermodynamic stresses which can drive fluid flow. Fluid flow in turn advects the composition field, while thermal noise creates additional random fluxes that allow the system to explore its configuration space and move towards the Boltzmann distribution. This article introduces continuum models of binary fluids, first covering some well-studied areas such as the thermodynamics and kinetics of phase separation, and emulsion stability. We then address cases where one of the fluid components has anisotropic structure at mesoscopic scales creating nematic (or polar) liquid-crystalline order; this can be described through an additional tensor (or vector) order parameter field. We conclude by outlining a thriving area of current research, namely active emulsions, in which one of the binary components consists of living or synthetic material that is continuously converting chemical energy into mechanical work.
Viscosity of thickened fluids that relate to the Australian National Standards.
Karsten Hadde, Enrico; Ann Yvette Cichero, Julie; Michael Nicholson, Timothy
2016-08-01
In 2007, Australia published standardized terminology and definitions for three levels of thickened fluids used in the management of dysphagia. This study examined the thickness of the current Australian National Fluid Standards rheologically (i.e. viscosity, yield stress) and correlated these results with the "fork test", as described in the national standards. Clinicians who prescribe or work with thickened liquids and laypersons were recruited to categorize 15 different thickened fluids of known viscosities using the fork test. The mean apparent viscosity and the yield stress for each fluid category were calculated. Clear responses were obtained by both clinicians and laypersons for very thin fluids (< 90 mPa.s) and very thick fluids (> 1150 mPa.s), but large variations of responses were seen for intermediate viscosities. Measures of viscosity and yield stress were important in allocating liquids to different categories. Three bands of fluid viscosity with distinct intermediate band gaps and associated yield stress measures were clearly identifiable and are proposed as objective complements to the Australian National Standards. The "fork test" provides rudimentary information about both viscosity and yield stress, but is an inexact measure of both variables.
Petrick, Michael; Pierson, Edward S.; Schreiner, Felix
1980-01-01
According to the present invention, coal combustion gas is the primary working fluid and copper or a copper alloy is the electrodynamic fluid in the MHD generator, thereby eliminating the heat exchangers between the combustor and the liquid-metal MHD working fluids, allowing the use of a conventional coalfired steam bottoming plant, and making the plant simpler, more efficient and cheaper. In operation, the gas and liquid are combined in a mixer and the resulting two-phase mixture enters the MHD generator. The MHD generator acts as a turbine and electric generator in one unit wherein the gas expands, drives the liquid across the magnetic field and thus generates electrical power. The gas and liquid are separated, and the available energy in the gas is recovered before the gas is exhausted to the atmosphere. Where the combustion gas contains sulfur, oxygen is bubbled through a side loop to remove sulfur therefrom as a concentrated stream of sulfur dioxide. The combustor is operated substoichiometrically to control the oxide level in the copper.
Brydges, Christopher R; Ozolnieks, Krista L; Roberts, Gareth
2017-09-01
Attention deficit/hyperactivity disorder (ADHD) is a psychological condition characterized by inattention and hyperactivity. Cognitive deficits are commonly observed in ADHD patients, including impaired working memory, processing speed, and fluid intelligence, the three of which are theorized to be closely associated with one another. In this study, we aimed to determine if decreased fluid intelligence was associated with ADHD, and was mediated by deficits in working memory and processing speed. This study tested 142 young adults from the general population on a range of working memory, processing speed, and fluid intelligence tasks, and an ADHD self-report symptoms questionnaire. Results showed that total and hyperactive ADHD symptoms correlated significantly and negatively with fluid intelligence, but this association was fully mediated by working memory. However, inattentive symptoms were not associated with fluid intelligence. Additionally, processing speed was not associated with ADHD symptoms at all, and was not uniquely predictive of fluid intelligence. The results provide implications for working memory training programs for ADHD patients, and highlight potential differences between the neuropsychological profiles of ADHD subtypes. © 2015 The British Psychological Society.
NASA Astrophysics Data System (ADS)
Gao, Yan; Liu, Yuyou
2017-06-01
Vibrational energy is transmitted in buried fluid-filled pipes in a variety of wave types. Axisymmetric (n = 0) waves are of practical interest in the application of acoustic techniques for the detection of leaks in underground pipelines. At low frequencies n = 0 waves propagate longitudinally as fluid-dominated (s = 1) and shell-dominated (s = 2) waves. Whilst sensors such as hydrophones and accelerometers are commonly used to detect leaks in water distribution pipes, the mechanism governing the structural and fluid motions is not well documented. In this paper, the low-frequency behaviour of the pipe wall and the contained fluid is investigated. For most practical pipework systems, these two waves are strongly coupled; in this circumstance the ratios of the radial pipe wall displacements along with the internal pressures associated with these two wave types are obtained. Numerical examples show the relative insensitivity of the structural and fluid motions to the s = 2 wave for both metallic and plastic pipes buried in two typical soils. It is also demonstrated that although both acoustic and vibration sensors at the same location provide the identical phase information of the transmitted signals, pressure responses have significantly higher levels than acceleration responses, and thus hydrophones are better suited in a low signal-to-noise ratio (SNR) environment. This is supported by experimental work carried out at a leak detection facility. Additional pressure measurements involved excitation of the fluid and the pipe fitting (hydrant) on a dedicated water pipe. This work demonstrates that the s = 1 wave is mainly responsible for the structural and fluid motions at low frequencies in water distribution pipes as a result of water leakage and direct pipe excitation.
Modeling Pumped Thermal Energy Storage with Waste Heat Harvesting
NASA Astrophysics Data System (ADS)
Abarr, Miles L. Lindsey
This work introduces a new concept for a utility scale combined energy storage and generation system. The proposed design utilizes a pumped thermal energy storage (PTES) system, which also utilizes waste heat leaving a natural gas peaker plant. This system creates a low cost utility-scale energy storage system by leveraging this dual-functionality. This dissertation first presents a review of previous work in PTES as well as the details of the proposed integrated bottoming and energy storage system. A time-domain system model was developed in Mathworks R2016a Simscape and Simulink software to analyze this system. Validation of both the fluid state model and the thermal energy storage model are provided. The experimental results showed the average error in cumulative fluid energy between simulation and measurement was +/- 0.3% per hour. Comparison to a Finite Element Analysis (FEA) model showed <1% error for bottoming mode heat transfer. The system model was used to conduct sensitivity analysis, baseline performance, and levelized cost of energy of a recently proposed Pumped Thermal Energy Storage and Bottoming System (Bot-PTES) that uses ammonia as the working fluid. This analysis focused on the effects of hot thermal storage utilization, system pressure, and evaporator/condenser size on the system performance. This work presents the estimated performance for a proposed baseline Bot-PTES. Results of this analysis showed that all selected parameters had significant effects on efficiency, with the evaporator/condenser size having the largest effect over the selected ranges. Results for the baseline case showed stand-alone energy storage efficiencies between 51 and 66% for varying power levels and charge states, and a stand-alone bottoming efficiency of 24%. The resulting efficiencies for this case were low compared to competing technologies; however, the dual-functionality of the Bot-PTES enables it to have higher capacity factor, leading to 91-197/MWh levelized cost of energy compared to 262-284/MWh for batteries and $172-254/MWh for Compressed Air Energy Storage.
Compression in Working Memory and Its Relationship With Fluid Intelligence.
Chekaf, Mustapha; Gauvrit, Nicolas; Guida, Alessandro; Mathy, Fabien
2018-06-01
Working memory has been shown to be strongly related to fluid intelligence; however, our goal is to shed further light on the process of information compression in working memory as a determining factor of fluid intelligence. Our main hypothesis was that compression in working memory is an excellent indicator for studying the relationship between working-memory capacity and fluid intelligence because both depend on the optimization of storage capacity. Compressibility of memoranda was estimated using an algorithmic complexity metric. The results showed that compressibility can be used to predict working-memory performance and that fluid intelligence is well predicted by the ability to compress information. We conclude that the ability to compress information in working memory is the reason why both manipulation and retention of information are linked to intelligence. This result offers a new concept of intelligence based on the idea that compression and intelligence are equivalent problems. Copyright © 2018 Cognitive Science Society, Inc.
Laser-launched flyers with organic working fluids
NASA Astrophysics Data System (ADS)
Mulford, Roberta; Swift, Damian
2003-10-01
The TRIDENT laser has been used to launch flyers by depositing IR energy in a thin layer of material - the working fluid - sandwiched between the flyer and a transparent substrate. We have investigated the use of working fluids based on organics, chosen as they are quite efficient absorbers of IR energy and should also convert heat to mechanical work more efficiently than materials such as carbon. A thermodynamically complete equation of state was developed for one of the fluids investigated experimentally - a carbohydrate solution - by chemical equilibrium calculations using the CHEETAH program. Continuum mechanics simulations were made of the flyer launch process, modeling the effect of the laser as energy deposition in the working fluid, and taking into account the compression and recoil of the substrate. We compare the simulations with a range of experiments and demonstrate the optimization of substrate and fluid thickness for a given flyer thickness and speed.
Compression in Working Memory and Its Relationship with Fluid Intelligence
ERIC Educational Resources Information Center
Chekaf, Mustapha; Gauvrit, Nicolas; Guida, Alessandro; Mathy, Fabien
2018-01-01
Working memory has been shown to be strongly related to fluid intelligence; however, our goal is to shed further light on the process of information compression in working memory as a determining factor of fluid intelligence. Our main hypothesis was that compression in working memory is an excellent indicator for studying the relationship between…
Simulational nanoengineering: Molecular dynamics implementation of an atomistic Stirling engine.
Rapaport, D C
2009-04-01
A nanoscale-sized Stirling engine with an atomistic working fluid has been modeled using molecular dynamics simulation. The design includes heat exchangers based on thermostats, pistons attached to a flywheel under load, and a regenerator. Key aspects of the behavior, including the time-dependent flows, are described. The model is shown to be capable of stable operation while producing net work at a moderate level of efficiency.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sandler, S.I.
1986-01-01
The objective of the work is to use the generalized van der Waals theory, as derived earlier (''The Generalized van der Waals Partition Function I. Basic Theory'' by S.I. Sandler, Fluid Phase Equilibria 19, 233 (1985)) to: (1) understand the molecular level assumptions inherent in current thermodynamic models; (2) use theory and computer simulation studies to test these assumptions; and (3) develop new, improved thermodynamic models based on better molecular level assumptions. From such a fundamental study, thermodynamic models will be developed that will be applicable to mixtures of molecules of widely different size and functionality, as occurs in themore » processing of heavy oils, coal liquids and other synthetic fuels. An important aspect of our work is to reduce our fundamental theoretical developments to engineering practice through extensive testing and evaluation with experimental data on real mixtures. During the first year of this project important progress was made in the areas specified in the original proposal, as well as several subsidiary areas identified as the work progressed. Some of this work has been written up and submitted for publication. Manuscripts acknowledging DOE support, together with a very brief description, are listed herein.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Murray, P.F.
1986-03-01
The Monsanto Chocolate Bayou plant has had an aggressive and successful energy conservation program. The combined efforts have resulted in a 80% reduction in unit energy consumption compared to 1972. The approach of using system audits to optimize fluid systems was developed. Since most of the fluid movers are centrifugal, the name Centrifugal Savings Task Force was adopted. There are three tools that are particularly valuable in optimizing fluid systems. First, a working level understanding of the Affinity Laws seems a must. In addition, the performance curves for the fluid movers is needed. The last need is accurate system fieldmore » data. Systems effectively managed at the Chocolate Bayou plant were process air improvement, feed-water pressure reduction, combustion air blower turbine speed control, and cooling tower pressure reduction. Optimization of centrifugal systems is an often-overlooked opportunity for energy savings. The basic guidelines are to move only the fluid needed, and move it at as low a pressure as possible.« less
NASA Technical Reports Server (NTRS)
Crowley, Christopher J.; Elkouhk, Nabil
2004-01-01
Two condensers designed for use in dissipating heat carried by working fluids feature two-phase, self-adjusting configurations such that their working lengths automatically vary to suit their input power levels and/or heat-sink temperatures. A key advantage of these condensers is that they can function even if the temperatures of their heat sinks fall below the freezing temperatures of their working fluids and the fluids freeze. The condensers can even be restarted from the frozen condition. The top part of the figure depicts the layout of the first condenser. A two-phase (liquid and vapor) condenser/vapor tube is thermally connected to a heat sink typically, a radiatively or convectively cooled metal panel. A single-phase (liquid) condensate-return tube (return artery) is also thermally connected to the heat sink. At intervals along their lengths, the condenser/vapor tube and the return artery are interconnected through porous plugs. This condenser configuration affords tolerance of freezing, variable effective thermal conductance (such that the return temperature remains nearly constant, independently of the ultimate sink temperature), and overall pressure drop smaller than it would be without the porous interconnections. An additional benefit of this configuration is that the condenser can be made to recover from the completely frozen condition either without using heaters, or else with the help of heaters much smaller than would otherwise be needed. The second condenser affords the same advantages and is based on a similar principle, but it has a different configuration that affords improved flow of working fluid, simplified construction, reduced weight, and faster recovery from a frozen condition.
High gliding fluid power generation system with fluid component separation and multiple condensers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mahmoud, Ahmad M; Lee, Jaeseon; Radcliff, Thomas D
2014-10-14
An example power generation system includes a vapor generator, a turbine, a separator and a pump. In the separator, the multiple components of the working fluid are separated from each other and sent to separate condensers. Each of the separate condensers is configured for condensing a single component of the working fluid. Once each of the components condense back into a liquid form they are recombined and exhausted to a pump that in turn drives the working fluid back to the vapor generator.
NASA Astrophysics Data System (ADS)
Cecere, Anselmo; De Cristofaro, Davide; Savino, Raffaele; Ayel, Vincent; Sole-Agostinelli, Thibaud; Marengo, Marco; Romestant, Cyril; Bertin, Yves
2018-06-01
A Flat Plate Pulsating Heat Pipe (FPPHP) filled with an ordinary liquid (water) and a self-rewetting mixture (dilutes aqueous solutions of long-chain alcohols with unusual surface tension behavior) is investigated under variable gravity conditions on board a 'Zero-g' plane during the 65th Parabolic Flight Campaign of the European Space Agency. The FPPHP thermal performance in terms of evaporator and condenser temperatures, start-up levels and flow regimes is characterized for the two working fluids and a power input ranging from 0 to 200 W (up to 17 W/cm2 at the heater/evaporator wall interface). The experimental set-up also includes a transparent plate enabling the visualization of the oscillating flow patterns during the experiments. For a low power input (4 W/cm2), the pulsating heat pipe filled with pure water is not able to work under low-g conditions, because the evaporator immediately exhibits dry-out conditions and the fluid oscillations stops, preventing heat transfer between the hot and cold side and resulting in a global increase of the temperatures. On the other hand, the FPPHP filled with the self-rewetting fluid runs also during the microgravity phase. The liquid rewets several times the evaporator zone triggering the oscillatory regime. The self-rewetting fluid helps both the start-up and the thermal performance of the FPPHP in microgravity conditions.
Wear forms of heterogeneous electro-rheological fluids working in a hydraulic clutch system
NASA Astrophysics Data System (ADS)
Ziabska, E.; Duchowski, J.; Olszak, A.; Osowski, K.; Kesy, A.; Kesy, Z.; Choi, S. B.
2017-09-01
The paper presents experimental results concerning the wear of heterogeneous electro-rheological (ER) fluids operating as working fluids in a complex clutch system consisting of a hydrodynamic clutch and a cylinder viscous clutch. The change of electric field intensity in the clutches results in change of sheer stress values in working fluids what causes the change of transmitted torque. This work shows that the most important factors affecting the wear of the ER fluid are the electric field of high intensity, the accompanying electrical breakdown, and the high temperature of the silicone oil. In addition, the water from the humid air absorbed mainly by hygroscopic particles influences a significant impact on the wear of the working fluid. Various forms of wear particles of the fluid depending on the prevailing conditions such as working mode are observed from the microscopic aspects. It is observed that the particles are flattened, rolled out or smashed into smaller fragments, partially melted, wrinkled and glued or caked. In addition, it is identified that the partial destruction of silicone oil is occurred due to the damage of the hydrocarbon chains, as evidenced by the decrease in its viscosity and the presence of the particle matter newly containing silicon.
Working Fluids for Increasing Capacities of Heat Pipes
NASA Technical Reports Server (NTRS)
Chao, David F.; Zhang, Nengli
2004-01-01
A theoretical and experimental investigation has shown that the capacities of heat pipes can be increased through suitable reformulation of their working fluids. The surface tensions of all of the working fluids heretofore used in heat pipes decrease with temperature. As explained in more detail below, the limits on the performance of a heat pipe are associated with the decrease in the surface tension of the working fluid with temperature, and so one can enhance performance by reformulating the working fluid so that its surface tension increases with temperature. This improvement is applicable to almost any kind of heat pipe in almost any environment. The heat-transfer capacity of a heat pipe in its normal operating-temperature range is subject to a capillary limit and a boiling limit. Both of these limits are associated with the temperature dependence of surface tension of the working fluid. In the case of a traditional working fluid, the decrease in surface tension with temperature causes a body of the liquid phase of the working fluid to move toward a region of lower temperature, thus preventing the desired spreading of the liquid in the heated portion of the heat pipe. As a result, the available capillary-pressure pumping head decreases as the temperature of the evaporator end of the heat pipe increases, and operation becomes unstable. Water has widely been used as a working fluid in heat pipes. Because the surface tension of water decreases with increasing temperature, the heat loads and other aspects of performance of heat pipes that contain water are limited. Dilute aqueous solutions of long-chain alcohols have shown promise as substitutes for water that can offer improved performance, because these solutions exhibit unusual surface-tension characteristics: Experiments have shown that in the cases of an aqueous solution of an alcohol, the molecules of which contain chains of more than four carbon atoms, the surface tension increases with temperature when the temperature exceeds a certain value. There are also other liquids that have surface tensions that increase with temperature and could be used as working fluids in heat pipes. For example, as a substitute for ammonia, which is the working fluid in some heat pipes, one could use a solution of ammonia and an ionic surfactant.
Coefficient of performance of Stirling refrigerators
NASA Astrophysics Data System (ADS)
E Mungan, Carl
2017-09-01
Stirling coolers transfer heat in or out of the working fluid during all four stages of their operation, and their coefficient of performance depends on whether the non-isothermal heat exchanges are performed reversibly or irreversibly. Both of these possibilities can in principle be arranged. Notably, if the working fluid is an ideal gas, the input of energy in the form of heat during one isochoric step is equal in magnitude to the output during the other isochoric step in the cycle. The theoretical performance of the fridge can then attain the reversible Carnot limit if a regenerator is used, which is a high heat capacity material through which the gas flows. Various Stirling refrigerator configurations are analysed in this article at a level of presentation suitable for an introductory undergraduate thermodynamics course.
NASA Astrophysics Data System (ADS)
Oliveira, E. C. M.; Silva, M. O. M.; Nunhez, J. R.; Ribeiro, e. L. C. L. J.
2016-08-01
The Computational Fluid Dynamics (CFD) is used to numerically simulate the behavior of fluid flow, and all the laws that rule the study of fluids, both the energy and mass transfer, chemical reactions, hydraulic behavior, and other applications. Among these innumerable applications, the local behavior of a mixing tank can be estimated using the CFD techniques. In order to follow-up studies in the literature giving them increased credibility, this project aimed to determine whether both the scheduling Potency/Volume and Torque/Volume maintain the necessary level of agitation in the mix tank to extrapolate the volume 10 times and 100 times, using an axial impeller blades inclined at 45 degrees type (PBT 45), and a radial impeller (Rushton turbine) with the use of the CFD. With the results, was analyzed if a criterion is superior to the other in terms of maintaining the level of agitation in scheduling. The case study made it possible to achieve the main objective, deepen studies in Computational Fluid Dynamics. Therefore, managed to the largest domain in tools offered by CFX-ANSYS 14.0 software, allowing future work to be conducted.
Rankine cycle waste heat recovery system
Ernst, Timothy C.; Nelson, Christopher R.
2015-09-22
A waste heat recovery (WHR) system connects a working fluid to fluid passages formed in an engine block and/or a cylinder head of an internal combustion engine, forming an engine heat exchanger. The fluid passages are formed near high temperature areas of the engine, subjecting the working fluid to sufficient heat energy to vaporize the working fluid while the working fluid advantageously cools the engine block and/or cylinder head, improving fuel efficiency. The location of the engine heat exchanger downstream from an EGR boiler and upstream from an exhaust heat exchanger provides an optimal position of the engine heat exchanger with respect to the thermodynamic cycle of the WHR system, giving priority to cooling of EGR gas. The configuration of valves in the WHR system provides the ability to select a plurality of parallel flow paths for optimal operation.
Fluid circulation determined in the isolated bovine lens.
Candia, Oscar A; Mathias, Richard; Gerometta, Rosana
2012-10-11
In 1997, a theoretical model was developed that predicted the existence of an internal, Na(+)-driven fluid circulation from the poles to the equator of the lens. In the present work, we demonstrate with a novel system that fluid movement can be measured across the polar and equatorial surface areas of isolated cow lenses. We have also determined the effects of ouabain and reduced bath [Na(+)]. Lenses were isolated in a chamber with three compartments separated by two thin O-rings. Each compartment, anterior (A), equatorial (E), and posterior (P), was connected to a vertical capillary graduated in 0.25 μL. Capillary levels were read every 15 minutes. The protocols consisted of 2 hours in either open circuit or short circuit. The effects of ouabain and low-Na(+) solutions were determined under open circuit. In 21 experiments, the E capillary increased at a mean rate of 0.060 μL/min while the A and P levels decreased at rates of 0.044 and 0.037 μL/min, respectively, closely accounting for the increase in E. The first-hour flows under short circuit were approximately 40% larger than those in open-circuit conditions. The first-hour flows were always larger than those during the second hour. Preincubation of lenses with either ouabain or low-[Na(+)] solutions resulted in reduced rates of fluid transport. When KCl was used to replace NaCl, a transitory stimulation of fluid transport occurred. These experiments support that a fluid circulation consistent with the 1997 model is physiologically active.
1998-01-01
The ideal biomarker for Alzheimer's disease (AD) should detect a fundamental feature of neuropathology and be validated in neuropathologically-confirmed cases; it should have a sensitivity >80% for detecting AD and a specificity of >80% for distinguishing other dementias; it should be reliable, reproducible, non-invasive, simple to perform, and inexpensive. Recommended steps to establish a biomarker include confirmation by at least two independent studies conducted by qualified investigators with the results published in peer-reviewed journals. Our review of current candidate markers indicates that for suspected early-onset familial AD, it is appropriate to search for mutations in the presenilin 1, presenilin 2, and amyloid precursor protein genes. Individuals with these mutations typically have increased levels of the amyloid Abeta42 peptide in plasma and decreased levels of APPs in cerebrospinal fluid. In late-onset and sporadic AD, these measures are not useful, but detecting an apolipoprotein E e4 allele can add confidence to the clinical diagnosis. Among the other proposed molecular and biochemical markers for sporadic AD, cerebrospinal fluid assays showing low levels of Abeta42 and high levels of tau come closest to fulfilling criteria for a useful biomarker.
Effects of real fluid properties on axial turbine meanline design and off-design analysis
NASA Astrophysics Data System (ADS)
MacLean, Cameron
The effects of real fluid properties on axial turbine meanline analysis have been investigated employing two meanline analysis codes, namely Turbine Meanline Design (TMLD) and Turbine Meanline Off-Design (TMLO). The previously developed TMLD code assumed the working fluid was an ideal gas. Therefore it was modified to use real fluid properties. TMLO was then developed from TMLD Both codes can be run using either the ideal gas assumption or real fluid properties. TMLD was employed for the meanline design of several axial turbines for a range of inlet conditions, using both the ideal gas assumption and real fluid properties. The resulting designs were compared to see the effects of real fluid properties. Meanline designs, generated using the ideal gas assumption, were then analysed with TMLO using real fluid properties. This was done over a range of inlet conditions that correspond to varying degrees of departure from ideal gas conditions. The goal was to show how machines designed with the ideal gas assumption would perform with the real working fluid. The working fluid used in both investigations was supercritical carbon dioxide. Results from the investigation show that real fluid properties had a strong effect on the gas path areas of the turbine designs as well as the performance of turbines designed using the ideal gas assumption. Specifically, power output and the velocities of the working fluid were affected. It was found that accounting for losses tended to lessen the effects of the real fluid properties.
Working Memory and Fluid Intelligence in Young Children
ERIC Educational Resources Information Center
Engel de Abreu, Pascale M. J.; Conway, Andrew R. A.; Gathercole, Susan E.
2010-01-01
The present study investigates how working memory and fluid intelligence are related in young children and how these links develop over time. The major aim is to determine which aspect of the working memory system--short-term storage or cognitive control--drives the relationship with fluid intelligence. A sample of 119 children was followed from…
A study of ethylene glycol exposure and kidney function of aircraft de-icing workers.
Gérin, M; Patrice, S; Bégin, D; Goldberg, M S; Vyskocil, A; Adib, G; Drolet, D; Viau, C
1997-01-01
Ethylene glycol levels were measured in 154 breathing zone air samples and in 117 urine samples of 33 aviation workers exposed to de-icing fluid (basket operators, de-icing truck drivers, leads and coordinators) studied during 42 worker-days over a winter period of 2 months at a Montreal airport. Ethylene glycol as vapour did not exceed 22 mg/m3 (mean duration of samples 50 min). Mist was quantified at higher levels in 3 samples concerning 1 coordinator and 2 basket operators (76-190 mg/m3, 45-118 min). In 16 cases workers' post-shift or next-morning urine contained quantities of ethylene glycol exceeding 5 mmol/mol creatinine (up to 129 mmol/mol creatinine), with most of these instances occurring in basket operators and coordinators, some of whom did not wear paper masks and/or were accidentally sprayed with de-icing fluid. Diethylene glycol was also found in a few air and urinary samples at levels around one tenth those of ethylene glycol. Urinary concentrations of albumin, beta-N-acetyl-glucosaminidase, beta-2-microglobulin and retinol-binding protein were measured and compared over various periods, according to subgroups based on exposure level and according to the frequency of extreme values. These analyses did not demonstrate acute or chronic kidney damage that could be attributed to working in the presence of ethylene glycol. In conclusion, this study does not suggest important health effects of exposure to de-icing fluid in this group of workers. Potential for overexposure exists, however, in certain work situations, and recommendations on preventive measures are given. In addition, these results suggest that other routes of absorption than inhalation, such as the percutaneous route, may be important and that urinary ethylene glycol may be a useful indicator of exposure to ethylene glycol.
Woskie, S R; Smith, T J; Hallock, M F; Hammond, S K; Rosenthal, F; Eisen, E A; Kriebel, D; Greaves, I A
1994-01-01
The current metal-working fluid exposures at three locations that manufacture automotive parts were assessed in conjunction with epidemiological studies of the mortality and respiratory morbidity experiences of workers at these plants. A rationale is presented for selecting and characterizing epidemiologic exposure groups in this environment. More than 475 full-shift personal aerosol samples were taken using a two-stage personal cascade impactor with median size cut-offs of 9.8 microns and 3.5 microns, plus a backup filter. For a sample of 403 workers exposed to aerosols of machining or grinding fluids, the mean total exposure was 706 micrograms/m3 (standard error (SE) = 21 micrograms/m3). Among 72 assemblers unexposed to machining fluids, the mean total exposure was 187 +/- 10 (SE) micrograms/m3. An analysis of variance model identified factors significantly associated with exposure level and permitted estimates of exposure for workers in the unsampled machine type/metal-working fluid groups. Comparison of the results obtained from personal impactor samples with predictions from an aerosol-deposition model for the human respiratory tract showed high correlation. However, the amount collected on the impactor stage underestimates extrathoracic deposition and overestimates tracheobronchial and alveolar deposition, as calculated by the deposition model. When both the impactor concentration and the deposition-model concentration were used to estimate cumulative thoracic concentrations for the worklives of a subset of auto workers, there was no significant difference in the rank order of the subjects' cumulative concentration. However, the cumulative impactor concentration values were significantly higher than the cumulative deposition-model concentration values for the subjects.
Thermal control systems for low-temperature heat rejection on a lunar base
NASA Technical Reports Server (NTRS)
Sridhar, K. R.; Gottmann, Matthias
1992-01-01
In this report, Rankine-cycle heat pumps and absorption heat pumps (ammonia-water and lithium bromide-water) have been analyzed and optimized for a lunar base cooling load of 100 kW. For the Rankine cycle, a search of several commonly used commercial refrigerants provided R11 and R717 as possible working fluids. Hence, the Rankine-cycle analysis has been performed for both R11 and R717. Two different configurations were considered for the system--one in which the heat pump is directly connected to the rejection loop and another in which a heat exchanger connects the heat pump to the rejection loop. For a marginal increase in mass, the decoupling of the rejection loop and the radiator from the heat pump provides greater reliability of the system and better control. Hence, the decoupled system is the configuration of choice. The optimal TCS mass for a 100 kW cooling load at 270 K was 5940 kg at a radiator temperature of 362 K. R11 was the working fluid in the heat pump, and R717 was the transport fluid in the rejection loop. Two TCS's based on an absorption-cycle heat pump were considered, one with an ammonia-water mixture and the other with a lithium bromide-water mixture as the working fluid. A complete cycle analysis was performed for these systems. The system components were approximated as heat exchangers with no internal pressure drop for the mass estimate. This simple approach underpredicts the mass of the systems, but is a good 'optimistic' first approximation to the TCS mass in the absence of reliable component mass data. The mass estimates of the two systems reveal that, in spite of this optimistic estimate, the absorption heat pumps are not competitive with the Rankine-cycle heat pumps. Future work at the systems level will involve similar analyses for the Brayton- and Stirling-cycle heat pumps. The analyses will also consider the operation of the pump under partial-load conditions. On the component level, a capillary evaporator will be designed, built, and tested in order to investigate its suitability in lunar base TCS and microgravity two-phase applications.
NASA Technical Reports Server (NTRS)
Ownens, Albert K.; Lavelle, Thomas M.; Hervol, David S.
2010-01-01
A Dual Brayton Power Conversion System (DBPCS) has been tested at the NASA Glenn Research Center using Nitrogen (N2) as the working fluid. This system uses two closed Brayton cycle systems that share a common heat source and working fluid but are otherwise independent. This system has been modeled using the Numerical Propulsion System Simulation (NPSS) environment. This paper presents the results of a numerical study that investigated system performance changes resulting when the working fluid is changed from gaseous (N2) to gaseous carbon dioxide (CO2).
Martínez-Gomez, Juan; Peña-Lamas, Javier; Martín, Mariano; Ponce-Ortega, José María
2017-12-01
The selection of the working fluid for Organic Rankine Cycles has traditionally been addressed from systematic heuristic methods, which perform a characterization and prior selection considering mainly one objective, thus avoiding a selection considering simultaneously the objectives related to sustainability and safety. The objective of this work is to propose a methodology for the optimal selection of the working fluid for Organic Rankine Cycles. The model is presented as a multi-objective approach, which simultaneously considers the economic, environmental and safety aspects. The economic objective function considers the profit obtained by selling the energy produced. Safety was evaluated in terms of individual risk for each of the components of the Organic Rankine Cycles and it was formulated as a function of the operating conditions and hazardous properties of each working fluid. The environmental function is based on carbon dioxide emissions, considering carbon dioxide mitigation, emission due to the use of cooling water as well emissions due material release. The methodology was applied to the case of geothermal facilities to select the optimal working fluid although it can be extended to waste heat recovery. The results show that the hydrocarbons represent better solutions, thus among a list of 24 working fluids, toluene is selected as the best fluid. Copyright © 2017 Elsevier Ltd. All rights reserved.
Viscoelastic stability in a single-screw channel flow
NASA Astrophysics Data System (ADS)
Agbessi, Y.; Bu, L. X.; Béreaux, Y.; Charmeau, J.-Y.
2018-05-01
In this work, we perform a linear stability analysis on pressure and drag flows of an Upper Convected Maxwell viscoelastic fluid. We use the well-recognised method of expanding the disturbances in Chebyschev polynomials and solve the resulting generalized eigenvalues problem with a collocation spectra method. Both the level of elasticity and the back-pressure vary. In a second stage, recent analytic solutions of viscoelastic fluid flows in slowly varying sections [1] are used to extend this stability analysis to flows in a compression or in a diverging section of a single screw channel, for example a wave mixing screw.
NASA Technical Reports Server (NTRS)
Kistler, E. L.
1972-01-01
A working report is presented in order to document early results of research on the stability of laminar boundary layers. The report shows that constitutive equations for a structured continua may be derived by the technique of reinterpreting velocity in the conventional stress to rate-of-strain relationship so as to account for effects of particle rotation. It is demonstrated that accounting for particle structure even at a molecular level makes the fluid viscoelastic with the ability to propagate vector waves. It is shown that particle structure modifies the basic stability equation for the system, which in turn would alter values for critical Reynolds number.
Self-contained small utility system
Labinov, Solomon D.; Sand, James R.
1995-01-01
A method and apparatus is disclosed to provide a fuel efficient source of readily converted energy to an isolated or remote energy consumption facility. External heat from any of a large variety of sources is converted to an electrical, mechanical, heat or cooling form of energy. A polyatomic working fluid energized by external heat sources is dissociated to a higher gaseous energy state for expansion through a turbine prime mover. The working fluid discharge from the turbine prime mover is routed to a recouperative heat exchanger for exothermic recombination reaction heat transfer to working fluid discharged from the compressor segment of the thermodynaic cycle discharge. The heated compressor discharge fluid is thereafter further heated by the external heat source to the initial higher energy state. Under the pressure at the turbine outlet, the working fluid goes out from a recouperative heat exchanger to a superheated vapor heat exchanger where it is cooled by ambient medium down to an initial temperature of condensation. Thereafter, the working fluid is condensed to a complete liquid state in a condenser cooled by an external medium. This liquid is expanded isenthalpically down to the lowest pressure of the cycle. Under this pressure, the working fluid is evaporated to the superheated vapor state of the inlet of a compressor.
Mitamura, Yoshinori; Takahashi, Sayaka; Amari, Shuichi; Okamoto, Eiji; Murabayashi, Shun; Nishimura, Ikuya
2011-03-01
A magnetic fluid (MF) seal enables mechanical contact-free rotation of the shaft and hence has excellent durability. The performance of an MF seal, however, has been reported to decrease in liquids. We developed an MF seal that has a "shield" mechanism, and a new MF with a higher magnetization of 47.9 kA/m. The sealing performance of the MF seal installed in a rotary blood pump was studied. Three types of MF seals were used. Seal A was a conventional seal without a shield. Seal B had the same structure as that of Seal A, but the seal was installed at 1 mm below liquid level. Seal C was a seal with a shield and the MF was set at 1 mm below liquid level. Seal A failed after 6 and 11 days. Seal B showed better results (20 and 73 days). Seal C showed long-term durability (217 and 275 days). The reason for different results in different seal structures was considered to be different flow conditions near the magnetic fluid. Fluid dynamics near the MF in the pump were analyzed using computational fluid dynamics (CFD) software. We have developed an MF seal with a shield that works in liquid for >275 days. The MF seal is promising as a shaft seal for rotary blood pumps.
Systems and methods for multi-fluid geothermal energy systems
Buscheck, Thomas A.
2017-09-19
A method for extracting geothermal energy from a geothermal reservoir formation. A production well is used to extract brine from the reservoir formation. At least one of nitrogen (N.sub.2) and carbon dioxide (CO.sub.2) may be used to form a supplemental working fluid which may be injected into a supplemental working fluid injection well. The supplemental working fluid may be used to augment a pressure of the reservoir formation, to thus drive a flow of the brine out from the reservoir formation.
Using Computational and Mechanical Models to Study Animal Locomotion
Miller, Laura A.; Goldman, Daniel I.; Hedrick, Tyson L.; Tytell, Eric D.; Wang, Z. Jane; Yen, Jeannette; Alben, Silas
2012-01-01
Recent advances in computational methods have made realistic large-scale simulations of animal locomotion possible. This has resulted in numerous mathematical and computational studies of animal movement through fluids and over substrates with the purpose of better understanding organisms’ performance and improving the design of vehicles moving through air and water and on land. This work has also motivated the development of improved numerical methods and modeling techniques for animal locomotion that is characterized by the interactions of fluids, substrates, and structures. Despite the large body of recent work in this area, the application of mathematical and numerical methods to improve our understanding of organisms in the context of their environment and physiology has remained relatively unexplored. Nature has evolved a wide variety of fascinating mechanisms of locomotion that exploit the properties of complex materials and fluids, but only recently are the mathematical, computational, and robotic tools available to rigorously compare the relative advantages and disadvantages of different methods of locomotion in variable environments. Similarly, advances in computational physiology have only recently allowed investigators to explore how changes at the molecular, cellular, and tissue levels might lead to changes in performance at the organismal level. In this article, we highlight recent examples of how computational, mathematical, and experimental tools can be combined to ultimately answer the questions posed in one of the grand challenges in organismal biology: “Integrating living and physical systems.” PMID:22988026
ERIC Educational Resources Information Center
Conway, Andrew R. A.; Cowan, Nelsin; Bunting, Michael F.; Therriault, David J.; Minkoff, Scott R. B.
2002-01-01
Studied the interrelationships among general fluid intelligence, short-term memory capacity, working memory capacity, and processing speed in 120 young adults and used structural equation modeling to determine the best predictor of general fluid intelligence. Results suggest that working memory capacity, but not short-term memory capacity or…
Design and optimization of organic rankine cycle for low temperature geothermal power plant
NASA Astrophysics Data System (ADS)
Barse, Kirtipal A.
Rising oil prices and environmental concerns have increased attention to renewable energy. Geothermal energy is a very attractive source of renewable energy. Although low temperature resources (90°C to 150°C) are the most common and most abundant source of geothermal energy, they were not considered economical and technologically feasible for commercial power generation. Organic Rankine Cycle (ORC) technology makes it feasible to use low temperature resources to generate power by using low boiling temperature organic liquids. The first hypothesis for this research is that using ORC is technologically and economically feasible to generate electricity from low temperature geothermal resources. The second hypothesis for this research is redesigning the ORC system for the given resource condition will improve efficiency along with improving economics. ORC model was developed using process simulator and validated with the data obtained from Chena Hot Springs, Alaska. A correlation was observed between the critical temperature of the working fluid and the efficiency for the cycle. Exergy analysis of the cycle revealed that the highest exergy destruction occurs in evaporator followed by condenser, turbine and working fluid pump for the base case scenarios. Performance of ORC was studied using twelve working fluids in base, Internal Heat Exchanger and turbine bleeding constrained and non-constrained configurations. R601a, R245ca, R600 showed highest first and second law efficiency in the non-constrained IHX configuration. The highest net power was observed for R245ca, R601a and R601 working fluids in the non-constrained base configuration. Combined heat exchanger area and size parameter of the turbine showed an increasing trend as the critical temperature of the working fluid decreased. The lowest levelized cost of electricity was observed for R245ca followed by R601a, R236ea in non-constrained base configuration. The next best candidates in terms of LCOE were R601a, R245ca and R600 in non-constrained IHX configuration. LCOE is dependent on net power and higher net power favors to lower the cost of electricity. Overall R245ca, R601, R601a, R600 and R236ea show better performance among the fluids studied. Non constrained configurations display better performance compared to the constrained configurations. Base non-constrained offered the highest net power and lowest LCOE.
Zook, Nancy A; Davalos, Deana B; Delosh, Edward L; Davis, Hasker P
2004-12-01
The contributions of working memory, inhibition, and fluid intelligence to performance on the Tower of Hanoi (TOH) and Tower of London (TOL) were examined in 85 undergraduate participants. All three factors accounted for significant variance on the TOH, but only fluid intelligence accounted for significant variance on the TOL. When the contribution of fluid intelligence was accounted for, working memory and inhibition continued to account for significant variance on the TOH. These findings support argument that fluid intelligence contributes to executive functioning, but also show that the executive processes elicited by tasks vary according to task structure.
Working memory training may increase working memory capacity but not fluid intelligence.
Harrison, Tyler L; Shipstead, Zach; Hicks, Kenny L; Hambrick, David Z; Redick, Thomas S; Engle, Randall W
2013-12-01
Working memory is a critical element of complex cognition, particularly under conditions of distraction and interference. Measures of working memory capacity correlate positively with many measures of real-world cognition, including fluid intelligence. There have been numerous attempts to use training procedures to increase working memory capacity and thereby performance on the real-world tasks that rely on working memory capacity. In the study reported here, we demonstrated that training on complex working memory span tasks leads to improvement on similar tasks with different materials but that such training does not generalize to measures of fluid intelligence.
Evaluation of an Integrated Gas-Cooled Reactor Simulator and Brayton Turbine-Generator
NASA Technical Reports Server (NTRS)
Hissam, David Andy; Stewart, Eric T.
2006-01-01
A closed-loop brayton cycle, powered by a fission reactor, offers an attractive option for generating both planetary and in-space electric power. Non-nuclear testing of this type of system provides the opportunity to safely work out integration and system control challenges for a modest investment. Recognizing this potential, a team at Marshall Space Flight Center has evaluated the viability of integrating and testing an existing gas-cooled reactor simulator and a modified commercially available, off-the-shelf, brayton turbine-generator. Since these two systems were developed independently of one another, this evaluation had to determine if they could operate together at acceptable power levels, temperatures, and pressures. Thermal, fluid, and structural analyses show that this combined system can operate at acceptable power levels and temperatures. In addition, pressure drops across the reactor simulator, although higher than desired, are also viewed as acceptable. Three potential working fluids for the system were evaluated: N2, He/Ar, and He/Xe. Other potential issues, such as electrical breakdown in the generator and the operation of the brayton foil bearings using various gas mixtures, were also investigated.
Thermal Vacuum/Balance Test Results of Swift BAT with Loop Heat Pipe Thermal System
NASA Technical Reports Server (NTRS)
Choi, Michael K.
2004-01-01
The Swift Burst Alert Telescope (BAT) Detector Array is thermally well coupled to eight constant conductance heat pipes (CCHPs) embedded in the Detector Array Plate PAP), and two loop heat pipes (LHPs) transport heat from the CCHPs to a radiator. The CCHPs have ammonia as the working fluid and the LHPs have propylene as the working fluid. Precision heater controllers, which have adjustable set points in flight, are used to control the LHP compensation chamber and Detector Array xA1 ASIC temperatures. The radiator has AZ-Tek's AZW-LA-II low solar absorptance white paint as the thermal coating, and is located on the anti-sun side of the spacecraft. A thermal balance (T/B) test on the BAT was successfully completed. It validated that the thermal design satisfies the temperature requirements of the BAT in the flight thermal environments. Instrument level and observatory level thermal vacuum (TN) cycling tests of the BAT Detector Array by using the LHP thermal system were successfully completed. This paper presents the results of the T/B test and T N cycling tests.
Fluid losses and hydration status of industrial workers under thermal stress working extended shifts
Brake, D; Bates, G
2003-01-01
Aims: To assess whether workers under significant thermal stress necessarily dehydrated during their exposure and whether "involuntary dehydration" was inevitable, as supported by ISO 9866 and other authorities. Other objectives were to quantify sweat rates against recommended occupational limits, to develop a dehydration protocol to assist with managing heat exposures, and to understand the role of meal breaks on extended shifts in terms of fluid replacement. Methods: A field investigation to examine the fluid consumption, sweat rates, and changes in the hydration state of industrial workers on extended (10, 12, and 12.5 hour) shifts under significant levels of thermal stress (wet bulb globe temperature (WBGT) >28°C) was conducted on 39 male underground miners. Urinary specific gravity was measured before, during, and at the completion of the working shift. Environmental conditions were measured hourly during the shift. Fluid replacement was measured during the working periods and during the meal breaks. Results: Average environmental conditions were severe (WBGT 30.9°C (SD 2.0°C), range 25.7–35.2°C). Fluid intake averaged 0.8 l/h during exposure (SD 0.3 l/h, range 0.3–1.5 l/h). Average urinary specific gravity at start, mid, and end of shift was 1.0251, 1.0248, and 1.0254 respectively; the differences between start and mid shift, mid and end shift, and start and end shift were not significant. However, a majority of workers were coming to work in a moderately hypohydrated state (average urinary specific gravity 1.024 (SD 0.0059)). A combined dehydration and heat illness protocol was developed. Urinary specific gravity limits of 1.022 for start of shift and 1.030 for end of shift were selected; workers exceeding these values were not allowed into the workplace (if the start of shift limit was exceeded) or were retested prior to their next working shift (if the end of shift limit was exceeded). A target of 1.015 as a euhydrated state for start of shift was adopted for workforce education. Conclusions: This study found that "involuntary dehydration" did not occur in well informed workers, which has implications for heat stress standards that do not make provision for full fluid replacement during heat exposure. Fluid replacement during meal breaks was not significantly increased above fluid replacement rates during work time, with implications for the duration and spacing of meal breaks on long shifts. Testing of urinary specific gravity was found to be a good indication of hydration status and a practical method of improving workforce awareness and understanding of this important risk factor. Approximately 10 000 dehydration tests have been conducted under the dehydration protocol in a workforce of 2000 persons exposed to thermal stress and has proved practical and reliable. PMID:12554834
Stirling engine with air working fluid
Corey, John A.
1985-01-01
A Stirling engine capable of utilizing air as a working fluid which includes a compact heat exchange module which includes heating tube units, regenerator and cooler positioned about the combustion chamber. This arrangement has the purpose and effect of allowing the construction of an efficient, high-speed, high power-density engine without the use of difficult to seal light gases as working fluids.
Frequency spectrum of transepithelial potential difference reveals transport-related oscillations.
Montalbetti, Nicolás; Fischbarg, Jorge
2009-09-16
How epithelia transport fluid is a fundamental issue that is unresolved. Explanations offered include molecular engines, local transcellular osmosis, local paracellular osmosis, and paracellular fluid transport. On the basis of experimental and theoretical work done on corneal endothelium, a fluid transporting epithelium, we suggest electroosmotic coupling at the level of the intercellular junctions driven by the transendothelial electrical potential difference as an explanation of paracellular fluid transport. We collect frequency spectra of that potential difference in real-time. For what we believe is the first time for any epithelium, we report that, unexpectedly, the potential difference displays oscillations at many characteristic frequencies. We also show that on both stimulating cell activity and inhibiting ion transport mechanisms, there are corresponding changes in the oscillations amplitudes that mirror changes known previously in rates of fluid transport. We believe these findings provide a novel tool to study the kinetics of electrogenic elements such as channels and transporters, which from this evidence would give rise to current oscillations with characteristic periods going from 150 ms to 8 s.
Coherent structures over Super Hydrophobic and Liquid Infused Surfaces
NASA Astrophysics Data System (ADS)
Arenas, Isnardo; Bernardini, Matteo; Leonardi, Stefano
2017-11-01
Numerical Simulations of two superposed fluids in a turbulent channel have been performed. Both walls of the channel are made of longitudinal riblets with a gas fractions of 0.5 and several pitch values p+ = 18 , 36 , 72 , 144 . For Liquid Infused Surfaces, LIS, with a viscosity ratio m =μ1 /μ2 = 0.4 (where the subscripts 1 and 2 indicate the fluid in the cavities and the overlying fluid respectively) two cases have been considered varying the Weber number: We = 0 , implying an interface sustained by the surface tension and We = 1000 with the dynamics of the interface between the two fluids modeled with a Level Set Approach. Results are compared to the case mimicking water over air (Super hydrophobic Surface SHS m = 0.02) and We = 0 . A smooth channel with one fluid only at Reτ = 180 is used as reference and to assess how the LIS and SHS modify coherent structures near the wall. Numerical simulations were performed on XSEDE TACC under Grant CTS070066. This work was supported by ONR MURI Grants N00014-12-01-0875 and N00014-12-01-0962.
From video to computation of biological fluid-structure interaction problems
NASA Astrophysics Data System (ADS)
Dillard, Seth I.; Buchholz, James H. J.; Udaykumar, H. S.
2016-04-01
This work deals with the techniques necessary to obtain a purely Eulerian procedure to conduct CFD simulations of biological systems with moving boundary flow phenomena. Eulerian approaches obviate difficulties associated with mesh generation to describe or fit flow meshes to body surfaces. The challenges associated with constructing embedded boundary information, body motions and applying boundary conditions on the moving bodies for flow computation are addressed in the work. The overall approach is applied to the study of a fluid-structure interaction problem, i.e., the hydrodynamics of swimming of an American eel, where the motion of the eel is derived from video imaging. It is shown that some first-blush approaches do not work, and therefore, careful consideration of appropriate techniques to connect moving images to flow simulations is necessary and forms the main contribution of the paper. A combination of level set-based active contour segmentation with optical flow and image morphing is shown to enable the image-to-computation process.
D'Antuono, Giovanni; La Torre, Francesca Romana; Marin, Dario; Antonucci, Gabriella; Piccardi, Laura; Guariglia, Cecilia
2017-01-01
We investigated the relationship between verbal and visuo-spatial measures of working memory, inhibition, fluid intelligence and the performance on the Tower of London (ToL) task in a large sample of 830 healthy participants aged between 18 and 71 years. We found that fluid intelligence and visuo-spatial working memory accounted for a significant variance in the ToL task, while performances on verbal working memory and on the Stroop Test were not predictive for performance on the ToL. The present results confirm that fluid intelligence has a fundamental role on planning tests, but also show that visuo-spatial working memory plays a crucial role in ToL performance.
Nagy, R A; van Montfoort, A P A; Dikkers, A; van Echten-Arends, J; Homminga, I; Land, J A; Hoek, A; Tietge, U J F
2015-05-01
Are bile acids (BA) and their respective subspecies present in human follicular fluid (FF) and do they relate to embryo quality in modified natural cycle IVF (MNC-IVF)? BA concentrations are 2-fold higher in follicular fluid than in serum and ursodeoxycholic acid (UDCA) derivatives were associated with development of top quality embryos on Day 3 after fertilization. Granulosa cells are capable of synthesizing BA, but a potential correlation with oocyte and embryo quality as well as information on the presence and role of BA subspecies in follicular fluid have yet to be investigated. Between January 2001 and June 2004, follicular fluid and serum samples were collected from 303 patients treated in a single academic centre that was involved in a multicentre cohort study on the effectiveness of MNC-IVF. Material from patients who underwent a first cycle of MNC-IVF was used. Serum was not stored from all patients, and the available material comprised 156 follicular fluid and 116 matching serum samples. Total BA and BA subspecies were measured in follicular fluid and in matching serum by enzymatic fluorimetric assay and liquid chromatography-mass spectrometry, respectively. The association of BA in follicular fluid with oocyte and embryo quality parameters, such as fertilization rate and cell number, presence of multinucleated blastomeres and percentage of fragmentation on Day 3, was analysed. Embryos with eight cells on Day 3 after oocyte retrieval were more likely to originate from follicles with a higher level of UDCA derivatives than those with fewer than eight cells (P < 0.05). Furthermore, follicular fluid levels of chenodeoxycholic derivatives were higher and deoxycholic derivatives were lower in the group of embryos with fragmentation compared with those without (each P < 0.05). Levels of total BA were 2-fold higher in follicular fluid compared with serum (P < 0.001), but had no predictive value for oocyte and embryo quality. Only samples originating from first cycle MNC-IVF were used, which resulted in 14 samples only from women with an ongoing pregnancy, therefore further prospective studies are required to confirm the association of UDCA with IVF pregnancy outcomes. The inter-cycle variability of BA levels in follicular fluid within individuals has yet to be investigated. We checked for macroscopic signs of contamination of follicular fluid by blood but the possibility that small traces of blood were present within the follicular fluid remains. Finally, although BA are considered stable when stored at -20°C, there was a time lag of 10 years between the collection and analysis of follicular fluid and serum samples. The favourable relation between UDCA derivatives in follicular fluid and good embryo development and quality deserves further prospective research, with live birth rates as the end-point. This work was supported by a grant from the Netherlands Organisation for Scientific Research (VIDI Grant 917-56-358 to U.J.F.T.). No competing interests are reported. © The Author 2015. Published by Oxford University Press on behalf of the European Society of Human Reproduction and Embryology. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Analysis of heat recovery of diesel engine using intermediate working fluid
NASA Astrophysics Data System (ADS)
Jin, Lei; Zhang, Jiang; Tan, Gangfeng; Liu, Huaming
2017-07-01
The organic Rankine cycle (ORC) is an effective way to recovery the engine exhaust heat. The thermal stability of the evaporation system is significant for the stable operation of the ORC system. In this paper, the performance of the designed evaporation system which combines with the intermediate fluid for recovering the exhaust waste heat from a diesel engine is evaluated. The thermal characteristics of the target diesel engine exhaust gas are evaluated based on the experimental data firstly. Then, the mathematical model of the evaporation system is built based on the geometrical parameters and the specific working conditions of ORC. Finally, the heat transfer characteristics of the evaporation system are estimated corresponding to three typical operating conditions of the diesel engine. The result shows that the exhaust temperature at the evaporator outlet increases slightly with the engine speed and load. In the evaporator, the heat transfer coefficient of the Rankine working fluid is slightly larger than the intermediate fluid. However, the heat transfer coefficient of the intermediate fluid in the heat exchanger is larger than the exhaust side. The heat transfer areas of the evaporator in both the two-phase zone and the preheated zone change slightly along with the engine working condition while the heat transfer areas of the overheated zone has changed obviously. The maximum heat transfer rate occurs in the preheating zone while the minimum value occurs in the overheating zone. In addition, the Rankine working fluid temperature at the evaporator outlet is not sensitively affected by the torque and speed of the engine and the organic fluid flow is relatively stable. It is concluded that the intermediate fluid could effectively reduce the physical changes of Rankine working fluid in the evaporator outlet due to changes in engine operating conditions.
Ultrasound for non-invasive fluid droplet detection inside a sealed container
NASA Astrophysics Data System (ADS)
Glass, S. W.; Good, M. S.; Roy, S.; Luzi, F.
2017-02-01
Ultrasound has long been known to be capable of measuring water level. Zero-degree ultrasound transducers may be used to send an L-wave through the fluid and receive a reflected signal from the fluid/gas interface surface. The level of the fluid is proportional to the sound wave time of flight to traverse the water path. This approach may even be used from outside the fluid containment wall by sending the wave through the tank or pipe bottom. The approach, however, does not work well if there is only a thin layer of fluid consisting of one or two millimeters or even only a few droplets. Surface waves are also known to be sensitive to the presence or absence of fluid on a surface. A surface wave may be transmitted a significant distance by a transmitting transducer and then received by a similar transducer. If the surface along the wave path is wet with even a few droplets of fluid, the surface wave may be significantly attenuated. Generating and measuring such a surface wave from the opposite side of a tank or pipe containment wall and separating the near-wall surface wave from the far-wall surface wave, however, is more challenging. The feasibility of an approach for producing a surface wave on the opposite side of a steel plate to sense the presence or absence of fluid is discussed. This approach is supported by 2-D finite element modeling of the measurement configuration and by empirical demonstration of the technique's sensitivity. This technique was developed for measurement of a very small amount of fluid that may condense within a used nuclear fuel canister after it cools for several years. Early detection of fluid would provide advance warning of potential degradation to internal components in time for mitigation or management of the waste inside that container. Other potential applications include non-intrusive detection of trace liquids within any sealed container, within inaccessible plena of aircrafts or within other inaccessible complex welded skin structures.
Fluid Circulation Determined in the Isolated Bovine Lens
Candia, Oscar A.; Mathias, Richard; Gerometta, Rosana
2012-01-01
Purpose. In 1997, a theoretical model was developed that predicted the existence of an internal, Na+-driven fluid circulation from the poles to the equator of the lens. In the present work, we demonstrate with a novel system that fluid movement can be measured across the polar and equatorial surface areas of isolated cow lenses. We have also determined the effects of ouabain and reduced bath [Na+]. Methods. Lenses were isolated in a chamber with three compartments separated by two thin O-rings. Each compartment, anterior (A), equatorial (E), and posterior (P), was connected to a vertical capillary graduated in 0.25 μL. Capillary levels were read every 15 minutes. The protocols consisted of 2 hours in either open circuit or short circuit. The effects of ouabain and low-Na+ solutions were determined under open circuit. Results. In 21 experiments, the E capillary increased at a mean rate of 0.060 μL/min while the A and P levels decreased at rates of 0.044 and 0.037 μL/min, respectively, closely accounting for the increase in E. The first-hour flows under short circuit were approximately 40% larger than those in open-circuit conditions. The first-hour flows were always larger than those during the second hour. Preincubation of lenses with either ouabain or low-[Na+] solutions resulted in reduced rates of fluid transport. When KCl was used to replace NaCl, a transitory stimulation of fluid transport occurred. Conclusions. These experiments support that a fluid circulation consistent with the 1997 model is physiologically active. PMID:22969071
Kuwajima, Mariko; Sawaguchi, Toshiyuki
2010-10-01
General fluid intelligence (gF) is a major component of intellect in both adults and children. Whereas its neural substrates have been studied relatively thoroughly in adults, those are poorly understood in children, particularly preschoolers. Here, we hypothesized that gF and visuospatial working memory share a common neural system within the lateral prefrontal cortex (LPFC) during the preschool years (4-6 years). At the behavioral level, we found that gF positively and significantly correlated with abilities (especially accuracy) in visuospatial working memory. Optical topography revealed that the LPFC of preschoolers was activated and deactivated during the visuospatial working memory task and the gF task. We found that the spatio-temporal features of neural activity in the LPFC were similar for both the visuospatial working memory task and the gF task. Further, 2 months of training for the visuospatial working memory task significantly increased gF in the preschoolers. These findings suggest that a common neural system in the LPFC is recruited to improve the visuospatial working memory and gF in preschoolers. Efficient recruitment of this neural system may be important for good performance in these functions in preschoolers, and behavioral training using this system would help to increase gF at these ages.
On The Dynamics And Kinematics Of Two Fluid Phase Flow In Porous Media
2015-06-16
fluid-fluid interfacial area density in a two-fluid-system. This dynamic equation set is unique to this work, and the importance of the modeled...saturation data intended to denote an equilibrium state is likely a sampling from a dynamic system undergoing changes of interfacial curvatures that are not... interfacial area density in a two-fluid-system. This dynamic equation set is unique to this work, and the importance of the modeled physics is shown
Shelton, Jill Talley; Elliott, Emily M.; Matthews, Russell A.; Hill, B. D.; Gouvier, Wm. Drew
2010-01-01
Recent efforts have been made to elucidate the commonly observed link between working memory and reasoning ability. The results have been inconsistent, with some work suggesting the emphasis placed on retrieval from secondary memory by working memory tests is the driving force behind this association (Mogle, Lovett, Stawski, & Sliwinski, 2008), while other research suggests retrieval from secondary memory is only partly responsible for the observed link between working memory and reasoning (Unsworth & Engle, 2006, 2007b). The present study investigates the relationship between processing speed, working memory, secondary memory, primary memory, and fluid intelligence. Although our findings show all constructs are significantly correlated with fluid intelligence, working memory, but not secondary memory, accounts for significant unique variance in fluid intelligence. Our data support predictions made by Unsworth and Engle, and suggest that the combined need for maintenance and retrieval processes present in working memory tests makes them “special” in their prediction of higher-order cognition. PMID:20438278
Kuipers works to remove the Marangoni Suface Fluid Physics Experiment
2012-03-15
ISS030-E-142784 (15 March 2012) --- European Space Agency astronaut Andre Kuipers, Expedition 30 flight engineer, works to remove the Marangoni Surface fluid physics experiment from the Fluid Physics Experiment Facility (FPEF) in the Kibo laboratory of the International Space Station.
Kuipers works to remove the Marangoni Suface Fluid Physics Experiment
2012-03-15
ISS030-E-142785 (15 March 2012) --- European Space Agency astronaut Andre Kuipers, Expedition 30 flight engineer, works to remove the Marangoni Surface fluid physics experiment from the Fluid Physics Experiment Facility (FPEF) in the Kibo laboratory of the International Space Station.
Transport Phenomena of Water in Molecular Fluidic Channels
Vo, Truong Quoc; Kim, BoHung
2016-01-01
In molecular-level fluidic transport, where the discrete characteristics of a molecular system are not negligible (in contrast to a continuum description), the response of the molecular water system might still be similar to the continuum description if the time and ensemble averages satisfy the ergodic hypothesis and the scale of the average is enough to recover the classical thermodynamic properties. However, even in such cases, the continuum description breaks down on the material interfaces. In short, molecular-level liquid flows exhibit substantially different physics from classical fluid transport theories because of (i) the interface/surface force field, (ii) thermal/velocity slip, (iii) the discreteness of fluid molecules at the interface and (iv) local viscosity. Therefore, in this study, we present the result of our investigations using molecular dynamics (MD) simulations with continuum-based energy equations and check the validity and limitations of the continuum hypothesis. Our study shows that when the continuum description is subjected to the proper treatment of the interface effects via modified boundary conditions, the so-called continuum-based modified-analytical solutions, they can adequately predict nanoscale fluid transport phenomena. The findings in this work have broad effects in overcoming current limitations in modeling/predicting the fluid behaviors of molecular fluidic devices. PMID:27650138
Heat recovery from sorbent-based CO.sub.2 capture
Jamal, Aqil; Gupta, Raghubir P
2015-03-10
The present invention provides a method of increasing the efficiency of exothermic CO.sub.2 capture processes. The method relates to withdrawing heat generated during the exothermic capture of CO.sub.2 with various sorbents via heat exchange with a working fluid. The working fluid is provided at a temperature and pressure such that it is in the liquid state, and has a vaporization temperature in a range such that the heat arising from the reaction of the CO.sub.2 and the sorbent causes a phase change from liquid to vapor state in whole or in part and transfers heat from to the working fluid. The resulting heated working fluid may subsequently be used to generate power.
ERIC Educational Resources Information Center
Moore, Pam
2008-01-01
Fluid power technicians, sometimes called hydraulic and pneumatic technicians, work with equipment that utilizes the pressure of a liquid or gas in a closed container to transmit, multiply, or control power. Working under the supervision of an engineer or engineering staff, they assemble, install, maintain, and test fluid power equipment.…
Exhaust turbine and jet propulsion systems
NASA Technical Reports Server (NTRS)
Leist, Karl; Knornschild, Eugen
1951-01-01
DVL experimental and analytical work on the cooling of turbine blades by using ram air as the working fluid over a sector or sectors of the turbine annulus area is summarized. The subsonic performance of ram-jet, turbo-jet, and turbine-propeller engines with both constant pressure and pulsating-flow combustion is investigated. Comparison is made with the performance of a reciprocating engine and the advantages of the gas turbine and jet-propulsion engines are analyzed. Nacelle installation methods and power-level control are discussed.
Stirling cycle engine and refrigeration systems
NASA Technical Reports Server (NTRS)
Higa, W. H. (Inventor)
1976-01-01
A Stirling cycle heat engine is disclosed in which displacer motion is controlled as a function of the working fluid pressure P sub 1 and a substantially constant pressure P sub 0. The heat engine includes an auxiliary chamber at the constant pressure P sub 0. An end surface of a displacer piston is disposed in the auxiliary chamber. During the compression portion of the engine cycle when P sub 1 rises above P sub 0 the displacer forces the working fluid to pass from the cold chamber to the hot chamber of the engine. During the expansion portion of the engine cycle the heated working fluid in the hot chamber does work by pushing down on the engine's drive piston. As the working fluid pressure P sub 1 drops below P sub 0 the displacer forces most of the working fluid in the hot chamber to pass through the regenerator to the cold chamber. The engine is easily combinable with a refrigeration section to provide a refrigeration system in which the engine's single drive piston serves both the engine and the refrigeration section.
NASA Astrophysics Data System (ADS)
Khan, F. A.; Yousaf, A.; Reindl, L. M.
2018-04-01
This paper presents a multi segment capacitive level monitoring sensor based on distributed E-fields approach Glocal. This approach has an advantage to analyze build-up problem by the local E-fields as well the fluid level monitoring by the global E-fields. The multi segment capacitive approach presented within this work addresses the main problem of unwanted parasitic capacitance generated from Copper (Cu) strips by applying active shielding concept. Polyvinyl chloride (PVC) is used for isolation and parafilm is used for creating artificial build-up on a CLS.
NASA Astrophysics Data System (ADS)
Duarte, Débora; Magalhães, Vitor Hugo; Terrinha, Pedro; Ribeiro, Carlos; Madureira, Pedro; Menezes Pinheiro, Luís; Benazzouz, Omar; Kim, Jung-Hyun; Duarte, Henrique
2017-04-01
Recently a field with more than 70 pockmarks was discovered in the NW region of the Estremadura Spur outer shelf (West Iberian margin), a trapezoidal promontory elongated in an east-west direction, between Cabo Carvoeiro and Cabo da Roca, extending until the Tore seamount. Pockmarks are the seabed culminations of fluid migration through the sedimentary column and their characteristic seabed morphologies correspond to cone-shaped circular or elliptical depressions. These features and the associated fluid escape process are the main objectives of this work. Here we characterize these structures to understand their structural and stratigraphic control based on: 1) Seismic processing and interpretation of the high resolution 2D single-channel sparker seismic dataset, 2) Bathymetric and Backscatter interpretation and 3) ROV direct observation of the seafloor. The analysis of the seismic profiles allowed the identification of six seismic units, disturbed by the migration and accumulation of fluids. The Estremadura Spur outer shelf has been affected by several episodes of fluid migration and fluid escape during the Pliocene-Quaternary that are expressed by a vast number of seabed and buried pockmarks. At present, the pockmarks are mainly inactive, as the seabed pockmarks are covered by recent sediments. The stacking of various pockmarks suggests a cyclical fluid flow activity that can possibly be the result of the eustatic sea level variations and the subsequent changes of the hydrostatic pressure. The origin of the seep fluids is still under debate but considering the low-sedimentation rate of the area and the low productivity a deep source for the fluids is most probable, possibly related with the Jurassic hydrocarbon system. It was concluded that the migration of fluids to the seabed occurred over the Pliocene-Quaternary in several episodes, as indicated by the buried pockmarks at different depths. Acknowledgements: This work was carried out in the framework of the PES project - Pockmarks and fluid seepage in the Estremadura Spur: implications for regional geology, biology, and petroleum systems (PTDC/GEOFIQ/5162/2014) financed by the Portuguese Foundation for Science and Technology (FCT). The seismic dataset was acquired within the PACEMAKER project funded by the European Research Council (ERC) under the European Union's Seventh Framework Program (FP7/2007-2013) ERC agreement (226600). The Instituto Portugues do Mar e da Atmosfera acknowledges support by Landmark Graphics (SeisWorks) via the Landmark University Grant Program. We thank the Estrutura de Missão para a Extensão da Plataforma Continental (EMEPC) for allowing me to have access and use the data collected in the Estremadura Spur during the EMEPC/PEPC/LUSO/2015 cruise and the ROV Luso team. We also thank Prof. Dr. Luis Matias (FCUL & IDL) for the help with SPW and processing steps.
Architecture of fluid intelligence and working memory revealed by lesion mapping.
Barbey, Aron K; Colom, Roberto; Paul, Erick J; Grafman, Jordan
2014-03-01
Although cognitive neuroscience has made valuable progress in understanding the role of the prefrontal cortex in human intelligence, the functional networks that support adaptive behavior and novel problem solving remain to be well characterized. Here, we studied 158 human brain lesion patients to investigate the cognitive and neural foundations of key competencies for fluid intelligence and working memory. We administered a battery of neuropsychological tests, including the Wechsler Adult Intelligence Scale (WAIS) and the N-Back task. Latent variable modeling was applied to obtain error-free scores of fluid intelligence and working memory, followed by voxel-based lesion-symptom mapping to elucidate their neural substrates. The observed latent variable modeling and lesion results support an integrative framework for understanding the architecture of fluid intelligence and working memory and make specific recommendations for the interpretation and application of the WAIS and N-Back task to the study of fluid intelligence in health and disease.
Flow regimes in a T-mixer operating with a binary mixture
NASA Astrophysics Data System (ADS)
Camarri, Simone; Siconolfi, Lorenzo; Galletti, Chiara; Salvetti, Maria Vittoria
2015-11-01
Efficient mixing in small volumes is a key target in many processes. Among the most common micro-devices, passive T-shaped micro-mixers are widely used. For this reason, T-mixers have been studied in the literature and its working flow regimes have been identified. However, in most of the available theoretical studies it is assumed that only one working fluid is used, i.e. that the same fluid at the same thermodynamic conditions is entering the two inlet conduits of the mixer. Conversely, the practical use of micro-devices often involves the mixing of two different fluids or of the same fluid at different thermodynamic conditions. In this case flow regimes significantly different than those observed for a single working fluid may occur. The present work aims at investigating the flow regimes in a T-mixers when water at two different temperatures, i.e. having different viscosity and density, is entering the mixer. The effect of the temperature difference on the flow regimes in a 3D T-mixer is investigated by DNS and stability analysis and the results are compared to the case in which a single working fluid is employed.
Working fluid selection for space-based two-phase heat transport systems
NASA Technical Reports Server (NTRS)
Mclinden, Mark O.
1988-01-01
The working fluid for externally-mounted, space-based two-phase heat transport systems is considered. A sequence of screening criteria involving freezing and critical point temperatures and latent heat of vaporization and vapor density are applied to a data base of 860 fluids. The thermal performance of the 52 fluids which pass this preliminary screening are then ranked according to their impact on the weight of a reference system. Upon considering other nonthermal criteria (flammability, toxicity, and chemical stability) a final set of 10 preferred fluids is obtained. The effects of variations in system parameters is investigated for these 10 fluids by means of a factorial design.
Oxidant and antioxidant status in children with subacute sclerosing panencephalitis.
Caksen, Hüseyin; Ozkan, Mustafa; Cemek, Mustafa; Cemek, Fatma
2014-11-01
We analyzed serum alpha-tocopherol, beta-carotene, retinol, and ascorbic acid levels and malondialdehyde and reduced glutathione concentrations on erythrocyte and cerebrospinal fluid in 30 patients with subacute sclerosing panencephalitis to evaluate oxidant and antioxidant status. Serum alpha-tocopherol, beta-carotene, retinol, ascorbic acid levels, and erythrocyte and cerebrospinal fluid reduced glutathione concentrations were decreased; however, erythrocyte and cerebrospinal fluid malondialdehyde levels were increased in the patients. Cerebrospinal fluid malondialdehyde levels were different between clinical stages of the disease (P < .05). Higher cerebrospinal fluid malondialdehyde level was associated with the more severe clinical stage. A positive correlation was found between cerebrospinal fluid malondialdehyde level and clinical stages (r = 0.42; P < .05) and between erythrocyte malondialdehyde level and clinical stages (r = 0.40; P < .05). Our findings showed presence of oxidative damage in subacute sclerosing panencephalitis and that antioxidants were increased as defense mechanisms of the organism against oxidative damage. © The Author(s) 2013.
NASA Technical Reports Server (NTRS)
Stochl, R. J.
1979-01-01
The results of an analysis to estimate the performance that could be obtained by using a chemically reacting gas (nitrogen tetroxide) as the working fluid in a closed Brayton cycle are presented. Compared with data for helium as the working fluid, these results indicate efficiency improvements from 4 to 90 percent, depending on turbine inlet temperature, pressures, and gas residence time in heat transfer equipment.
Metalworking and machining fluids
Erdemir, Ali; Sykora, Frank; Dorbeck, Mark
2010-10-12
Improved boron-based metal working and machining fluids. Boric acid and boron-based additives that, when mixed with certain carrier fluids, such as water, cellulose and/or cellulose derivatives, polyhydric alcohol, polyalkylene glycol, polyvinyl alcohol, starch, dextrin, in solid and/or solvated forms result in improved metalworking and machining of metallic work pieces. Fluids manufactured with boric acid or boron-based additives effectively reduce friction, prevent galling and severe wear problems on cutting and forming tools.
González-Herrera, Lucas; Valenzuela, Aurora; Ramos, Valentín; Blázquez, Antonia; Villanueva, Enrique
2016-06-01
The main objective of this study was to test, for the first time, a highly sensitive cardiac troponin T (cTnThs) assay in postmortem serum and pericardial fluid and to evaluate cardiac troponin T (cTnT) levels and their stability after death at different postmortem intervals, in an attempt to determine the viability of the cTnThs assay in the postmortem diagnosis of the cause of death. cTnT levels were determined in serum and pericardial fluid samples taken from 58 cadavers at known postmortem intervals, whose causes of death were categorized into the following groups: (1) sudden cardiac deaths, (2) multiple trauma, (3) mechanical asphyxia, and (4) other natural deaths. cTnT was determined by inmunoassay, using the Troponin T highly sensitive STAT assay (Roche(®)). Average cTnT levels measured by a highly sensitive assay in postmortem serum were markedly higher than clinical serum levels. Moreover, similar results, higher cTnT levels in postmortem pericardial fluid, were obtained when compared to levels found in pericardial fluid taken from two living patients during coronary artery bypass surgery. cTnT levels in both postmortem fluids remained stable for up to 34 h after death. No differences in cTnT levels in either postmortem fluid by sex and age were detected. Levels of cTnT found in pericardial fluid in the other natural deaths group were significantly lower than the cTnT levels found in that postmortem fluid from any of the other causes of death groups. It is therefore reasonable to conclude that determination of cTnT by a highly sensitive assay in pericardial fluid can provide forensic pathologists with a complementary test to the diagnosis of cause of death.
A contemporary look at Hermann Hankel's 1861 pioneering work on Lagrangian fluid dynamics
NASA Astrophysics Data System (ADS)
Frisch, Uriel; Grimberg, Gérard; Villone, Barbara
2017-12-01
The present paper is a companion to the paper by Villone and Rampf (2017), titled "Hermann Hankel's On the general theory of motion of fluids, an essay including an English translation of the complete Preisschrift from 1861" together with connected documents [Eur. Phys. J. H 42, 557-609 (2017)]. Here we give a critical assessment of Hankel's work, which covers many important aspects of fluid dynamics considered from a Lagrangian-coordinates point of view: variational formulation in the spirit of Hamilton for elastic (barotropic) fluids, transport (we would now say Lie transport) of vorticity, the Lagrangian significance of Clebsch variables, etc. Hankel's work is also put in the perspective of previous and future work. Hence, the action spans about two centuries: from Lagrange's 1760-1761 Turin paper on variational approaches to mechanics and fluid mechanics problems to Arnold's 1966 founding paper on the geometrical/variational formulation of incompressible flow. The 22-year-old Hankel - who was to die 12 years later — emerges as a highly innovative master of mathematical fluid dynamics, fully deserving Riemann's assessment that his Preisschrift contains "all manner of good things."
Pozo, P; Valenzuela, M A; Melej, C; Zaldívar, M; Puente, J; Martínez, B; Gamonal, J
2005-06-01
The aim of this work was to improve the assessment of the periodontal disease status through measurements of extracellular matrix metalloproteinases (MMPs) and their tissular inhibitors (TIMPs) in the gingival crevicular fluid from patients diagnosed with chronic periodontitis. Gingival crevicular fluid samples from patients (n = 13) were taken from 60 sites initially, and from 51 and 41 sites, respectively, 3 and 6 months after scaling and root planing. Gingival crevicular fluid samples were also taken from healthy subjects (n = 11, 24 sites). The presence of MMP-9 and MMP-8 was assessed by zymography and immunowestern blotting, respectively. The actual MMP activity (gelatinase and collagenase) was measured using the fluorogenic substrate assay. TIMP-1 and -2 levels were measured by immunodot blot. The fluorogenic substrate assay determinations showed higher MMP activity in sites with probing depth > or = 4 mm, with significant reduction post-treatment. Gelatinase activity followed by zymography consisted mainly of MMP-9. A different pattern of MMP-8 in control and patient sites was found. Controls only showed species of a partially active form (69 kDa), whereas patient sites showed a high frequency of the active form (56 kDa), and in some cases the latent form (85 kDa) was also observed. The active form reduced its frequency in sites with probing depth > or = 4 mm. TIMP-1 and -2 levels in patients were significantly lower than in controls, and after treatment the recovery of TIMP-1 level similar to control was observed. Significant correlations between the severity of the periodontal disease and the actual MMP activity, the active form of MMP-8 and the low level of both TIMP-1 and TIMP-2 were found.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pan, Feng; McPherson, Brian J.; Kaszuba, John
Recent studies suggest that using supercritical CO 2 (scCO 2 ) instead of water as a heat transmission fluid in Enhanced Geothermal Systems (EGS) may improve energy extraction. While CO 2 -fluid-rock interactions at “typical” temperatures and pressures of subsurface reservoirs are fairly well known, such understanding for the elevated conditions of EGS is relatively unresolved. Geochemical impacts of CO 2 as a working fluid (“CO 2 -EGS”) compared to those for water as a working fluid (H 2 O-EGS) are needed. The primary objectives of this study are (1) constraining geochemical processes associated with CO 2 -fluid-rock interactions undermore » the high pressures and temperatures of a typical CO 2 -EGS site and (2) comparing geochemical impacts of CO 2 -EGS to geochemical impacts of H 2 O-EGS. The St. John’s Dome CO 2 -EGS research site in Arizona was adopted as a case study. A 3D model of the site was developed. Net heat extraction and mass flow production rates for CO 2 -EGS were larger compared to H 2 O-EGS, suggesting that using scCO 2 as a working fluid may enhance EGS heat extraction. More aqueous CO 2 accumulates within upper- and lower-lying layers than in the injection/production layers, reducing pH values and leading to increased dissolution and precipitation of minerals in those upper and lower layers. Dissolution of oligoclase for water as a working fluid shows smaller magnitude in rates and different distributions in profile than those for scCO 2 as a working fluid. It indicates that geochemical processes of scCO 2 -rock interaction have significant effects on mineral dissolution and precipitation in magnitudes and distributions.« less
Pan, Feng; McPherson, Brian J.; Kaszuba, John
2017-01-01
Recent studies suggest that using supercritical CO 2 (scCO 2 ) instead of water as a heat transmission fluid in Enhanced Geothermal Systems (EGS) may improve energy extraction. While CO 2 -fluid-rock interactions at “typical” temperatures and pressures of subsurface reservoirs are fairly well known, such understanding for the elevated conditions of EGS is relatively unresolved. Geochemical impacts of CO 2 as a working fluid (“CO 2 -EGS”) compared to those for water as a working fluid (H 2 O-EGS) are needed. The primary objectives of this study are (1) constraining geochemical processes associated with CO 2 -fluid-rock interactions undermore » the high pressures and temperatures of a typical CO 2 -EGS site and (2) comparing geochemical impacts of CO 2 -EGS to geochemical impacts of H 2 O-EGS. The St. John’s Dome CO 2 -EGS research site in Arizona was adopted as a case study. A 3D model of the site was developed. Net heat extraction and mass flow production rates for CO 2 -EGS were larger compared to H 2 O-EGS, suggesting that using scCO 2 as a working fluid may enhance EGS heat extraction. More aqueous CO 2 accumulates within upper- and lower-lying layers than in the injection/production layers, reducing pH values and leading to increased dissolution and precipitation of minerals in those upper and lower layers. Dissolution of oligoclase for water as a working fluid shows smaller magnitude in rates and different distributions in profile than those for scCO 2 as a working fluid. It indicates that geochemical processes of scCO 2 -rock interaction have significant effects on mineral dissolution and precipitation in magnitudes and distributions.« less
Li, Jinghong; Li, Jinyi; Jia, Yanjie
2012-04-15
In this study, the levels of soluble delta-like ligand 1 in cerebrospinal fluid and serum of 50 patients with tuberculous meningitis, 30 patients with viral meningitis, 20 patients with purulent meningitis and 40 subjects without central nervous system disease were determined using an enzyme-linked immunosorbent assay. The mean levels of soluble delta-like ligand 1 in both cerebrospinal fluid and serum from patients with tuberculous meningitis were significantly higher compared with those from patients with viral meningitis or purulent meningitis or from subjects without central nervous system disease. Meanwhile, the level of soluble delta-like ligand 1 gradually decreased as tuberculous meningitis patients recovered. If patients deteriorated after treatment, the level of soluble delta-like ligand 1 in cerebrospinal fluid gradually increased. There was no correlation between the level of soluble delta-like ligand 1 and the protein level/cell number in cerebrospinal fluid. Our findings indicate that the levels of soluble delta-like ligand 1 in cerebrospinal fluid and serum are reliable markers for the diagnosis of tuberculous meningitis and for monitoring treatment progress. At the same time, this index is not influenced by protein levels or cell numbers in cerebrospinal fluid.
Fluids and Materials Science Studies Utilizing the Microgravity-vibration Isolation Mount (MIM)
NASA Technical Reports Server (NTRS)
Herring, Rodney; Tryggvason, Bjarni; Duval, Walter
1998-01-01
Canada's Microgravity Sciences Program (MSP) is the smallest program of the ISS partners and so can participate in only a few, highly focused projects in order to make a scientific and technological impact. One focused project involves determining the effect of accelerations (g-jitter) on scientific measurements in a microgravity environment utilizing the Microgravity-vibration Isolation Mount (MIM). Many experiments share the common characteristic of having a fluid stage in their process. The quality of the experimental measurements have been expected to be affected by g-jitters which has lead the ISS program to include specifications to limit the level of acceleration allowed on a subset of experimental racks. From finite element analysis (FEM), the ISS structure will not be able to meet the acceleration specifications. Therefore, isolation systems are necessary. Fluid science results and materials science results show significant sensitivity to g-jitter. The work done to date should be viewed only as a first look at the issue of g-jitter sensitivity. The work should continue with high priority such that the international science community and the ISS program can address the requirement and settle on an agreed to overall approach as soon as possible.
Working research codes into fluid dynamics education: a science gateway approach
NASA Astrophysics Data System (ADS)
Mason, Lachlan; Hetherington, James; O'Reilly, Martin; Yong, May; Jersakova, Radka; Grieve, Stuart; Perez-Suarez, David; Klapaukh, Roman; Craster, Richard V.; Matar, Omar K.
2017-11-01
Research codes are effective for illustrating complex concepts in educational fluid dynamics courses, compared to textbook examples, an interactive three-dimensional visualisation can bring a problem to life! Various barriers, however, prevent the adoption of research codes in teaching: codes are typically created for highly-specific `once-off' calculations and, as such, have no user interface and a steep learning curve. Moreover, a code may require access to high-performance computing resources that are not readily available in the classroom. This project allows academics to rapidly work research codes into their teaching via a minimalist `science gateway' framework. The gateway is a simple, yet flexible, web interface allowing students to construct and run simulations, as well as view and share their output. Behind the scenes, the common operations of job configuration, submission, monitoring and post-processing are customisable at the level of shell scripting. In this talk, we demonstrate the creation of an example teaching gateway connected to the Code BLUE fluid dynamics software. Student simulations can be run via a third-party cloud computing provider or a local high-performance cluster. EPSRC, UK, MEMPHIS program Grant (EP/K003976/1), RAEng Research Chair (OKM).
NASA Technical Reports Server (NTRS)
Bhandari, Pradeep; Dudik, Brenda; Birur, Gajanana; Karlmann, Paul; Bame, David; Mastropietro, A. J.
2012-01-01
For single phase mechanically pumped fluid loops used for thermal control of spacecraft, a gas charged accumulator is typically used to modulate pressures within the loop. This is needed to accommodate changes in the working fluid volume due to changes in the operating temperatures as the spacecraft encounters varying thermal environments during its mission. Overall, the three key requirements on the accumulator to maintain an appropriate pressure range throughout the mission are: accommodation of the volume change of the fluid due to temperature changes, avoidance of pump cavitation and prevention of boiling in the liquid. The sizing and design of such an accumulator requires very careful and accurate accounting of temperature distribution within each element of the working fluid for the entire range of conditions expected, accurate knowledge of volume of each fluid element, assessment of corresponding pressures needed to avoid boiling in the liquid, as well as the pressures needed to avoid cavitation in the pump. The appropriate liquid and accumulator strokes required to accommodate the liquid volume change, as well as the appropriate gas volumes, require proper sizing to ensure that the correct pressure range is maintained during the mission. Additionally, a very careful assessment of the process for charging both the gas side and the liquid side of the accumulator is required to properly position the bellows and pressurize the system to a level commensurate with requirements. To achieve the accurate sizing of the accumulator and the charging of the system, sophisticated EXCEL based spreadsheets were developed to rapidly come up with an accumulator design and the corresponding charging parameters. These spreadsheets have proven to be computationally fast and accurate tools for this purpose. This paper will describe the entire process of designing and charging the system, using a case study of the Mars Science Laboratory (MSL) fluid loops, which is en route to Mars for an August 2012 landing.
Mirer, Franklin E
2010-08-01
Metalworking fluids (MWF) are used in the manufacture of engines, transmissions, chassis parts and other products. In 2003, OSHA denied a union petition to promulgate a standard for MWF. The 3rd Circuit Court of Appeals rejected a union lawsuit to compel OSHA to regulate MWF. OSHA relied exclusively on the 1999 Metal Working Fluids Standards Advisory Committee report, therefore, only evidence available before 1999 was quoted supporting the denial. This review was conducted to identify studies published since 1998. Electronic reference sources were queried for the terms for metalworking fluids, machining fluids, cutting fluids, cutting oils, coolants, machining, and machinist. All items returned were reviewed for relevance to MWF regulation. The review noted 227 reports in the peer reviewed literature directly relevant to regulation of MWF exposures. Of these, 26 addressed cancer; 58 respiratory effects; 32 skin effects or absorption; 45 microbial contaminants; and 76 exposure measurements and controls. Three major studies identified excess cancer including lung, liver, pancreatic, laryngeal, and leukemia associated with MWF exposures. Reports strengthened associations of asthma and hypersensitivity pneumonitis with recent exposure to MWF. Material new evidence demonstrates significant risks to material impairment of health at prevailing exposure levels and feasibility of lower exposure limits. Copyright 2010 Wiley-Liss, Inc.
Wileman, Vari; Chilcot, Joseph; Armitage, Christopher J; Farrington, Ken; Wellsted, David M; Norton, Sam; Davenport, Andrew; Franklin, Gail; Da Silva Gane, Maria; Horne, Robert; Almond, Mike
2016-01-01
Haemodialysis patients are at risk of serious health complications; yet, treatment non-adherence remains high. Warnings about health risks associated with non-adherence may trigger defensive reactions. We studied whether an intervention based on self-affirmation theory reduced resistance to health-risk information and improved fluid treatment adherence. In a cluster randomised controlled trial, 91 patients either self-affirmed or completed a matched control task before reading about the health-risks associated with inadequate fluid control. Patients' perceptions of the health-risk information, intention and self-efficacy to control fluid were assessed immediately after presentation of health-risk information. Interdialytic weight gain (IDWG), excess fluid removed during haemodialysis, is a clinical measure of fluid treatment adherence. IDWG data were collected up to 12 months post-intervention. Self-affirmed patients had significantly reduced IDWG levels over 12 months. However, contrary to predictions derived from self-affirmation theory, self-affirmed participants and controls did not differ in their evaluation of the health-risk information, intention to control fluid or self-efficacy. A low-cost, high-reach health intervention based on self-affirmation theory was shown to reduce IDWG over a 12-month period, but the mechanism by which this apparent behaviour change occurred is uncertain. Further work is still required to identify mediators of the observed effects.
Organosiloxane working fluids for the liquid droplet radiator
NASA Technical Reports Server (NTRS)
Buch, R. R.; Huntress, A. R.
1985-01-01
Siloxane-based working fluids for advanced space radiators requiring direct fluid exposure to the space environment are evaluated. Isolation of five candidate fluids by vacuum distillation from existing siloxane polymers is discussed. The five fluids recovered include a polydimethylsiloxane, three phenyl-containing siloxanes, and a methylhexylsiloxane. Vapor pressures and viscosities for the five fluids are reported over the temperature range of 250 to 400 K. Use of thermal-gravimetric analysis to reliably estimate vapor pressures of 10 to the -8 power Pascals is described. Polydimethylsiloxane (PDMS) and polymethylphenylsiloxane (PMPS) are selected from the five candidate fluids based on favorable vapor pressure and viscosity, as well as perceived stability in low-Earth orbit environments. Characterization of these fluids by infrared spectroscopy, Si-29 NMR, gel-permeation chromatography, and liquid chromatography is presented. Both fluids consist of narrow molecular weight distributions, with average molecular weights of about 2500 for PDMS and 1300 for PMPS.
Density Relaxation of Liquid-Vapor Critical Fluids Examined in Earth's Gravity
NASA Technical Reports Server (NTRS)
Wilkinson, R. Allen
2000-01-01
This work shows quantitatively the pronounced differences between the density equilibration of very compressible dense fluids in Earth's gravity and those in microgravity. The work was performed onsite at the NASA Glenn Research Center at Lewis Field and is complete. Full details are given in references 1 and 2. Liquid-vapor critical fluids (e.g., water) at their critical temperature and pressure, are very compressible. They collapse under their own weight in Earth's gravity, allowing only a thin meniscus-like layer with the critical pressure to survive. This critical layer, however, greatly slows down the equilibration process of the entire sample. A complicating feature is the buoyancy-driven slow flows of layers of heavier and lighter fluid. This work highlights the incomplete understanding of the hydrodynamics involved in these fluids.
Fluid Dynamics Lagrangian Simulation Model
NASA Astrophysics Data System (ADS)
Hyman, Ellis
1994-02-01
The work performed by Science Applications International Corporation (SAIC) on this contract, Fluid Dynamics Lagrangian Simulation Model, Contract Number N00014-89-C-2106, SAIC Project Number 01-0157-03-0768, focused on a number of research topics in fluid dynamics. The work was in support of the programs of NRL's Laboratory for Computational Physics and Fluid Dynamics and covered the period from 10 September 1989 to 9 December 1993. In the following sections, we describe each of the efforts and the results obtained. Much of the research work has resulted in journal publications. These are included in Appendices of this report for which the reader is referred for complete details.
Novakova, Lenka; Axelsson, Markus; Malmeström, Clas; Imberg, Henrik; Elias, Olle; Zetterberg, Henrik; Nerman, Olle; Lycke, Jan
2018-01-01
Neurodegeneration occurs during the early stages of multiple sclerosis. It is an essential, devastating part of the pathophysiology. Tools for measuring the degree of neurodegeneration could improve diagnostics and patient characterization. This study aimed to determine the diagnostic value of biomarkers of degeneration in patients with recent clinical onset of suspected multiple sclerosis, and to evaluate these biomarkers for characterizing disease course. This cross-sectional study included 271 patients with clinical features of suspected multiple sclerosis onset and was the baseline of a prospective study. After diagnostic investigations, the patients were classified into the following disease groups: patients with clinically isolated syndrome (n = 4) or early relapsing remitting multiple sclerosis (early RRMS; n = 93); patients with relapsing remitting multiple sclerosis with disease durations ≥2 years (established RRMS; n = 39); patients without multiple sclerosis, but showing symptoms (symptomatic controls; n = 89); and patients diagnosed with other diseases (n = 46). In addition, we included healthy controls (n = 51) and patients with progressive multiple sclerosis (n = 23). We analyzed six biomarkers of neurodegeneration: cerebrospinal fluid neurofilament light chain levels; cerebral spinal fluid glial fibrillary acidic protein; cerebral spinal fluid tau; retinal nerve fiber layer thickness; macula volume; and the brain parenchymal fraction. Except for increased cerebral spinal fluid neurofilament light chain levels, median 670 ng/L (IQR 400-2110), we could not find signs of early degeneration in the early disease group with recent clinical onset. However, the intrathecal immunoglobin G production and cerebral spinal fluid neurofilament light chain levels showed diagnostic value. Moreover, elevated levels of cerebral spinal fluid glial fibrillary acidic protein, thin retinal nerve fiber layers, and low brain parenchymal fractions were associated with progressive disease, but not with the other phenotypes. Thin retinal nerve fiber layers and low brain parenchymal fractions, which indicated neurodegeneration, were associated with longer disease duration. In clinically suspected multiple sclerosis, intrathecal immunoglobin G production and neurofilament light chain levels had diagnostic value. Therefore, these biomarkers could be included in diagnostic work-ups for multiple sclerosis. We found that the thickness of the retinal nerve fiber layer and the brain parenchymal fraction were not different between individuals that were healthy, symptomatic, or newly diagnosed with multiple sclerosis. This finding suggested that neurodegeneration had not reached a significant magnitude in patients with a recent clinical onset of multiple sclerosis.
Optimum working fluids for solar powered Rankine cycle cooling of buildings
NASA Astrophysics Data System (ADS)
Wali, E.
1980-01-01
A number of fluids were screened for their operational reliability and thermal stability as working fluids for domestic solar Rankine cycle cooling. The results indicate that the halogenated compound R-113, followed by the fluorinated compound FC-88, is best suited for safe Rankine cycle operation. Further dynamic investigations are, however, needed to study the thermal stability of these fluids in the presence and absence of lubricants in copper, steel, and alloy conduits
Pre-shift fluid intake: effect on physiology, work and drinking during emergency wildfire fighting.
Raines, Jenni; Snow, Rodney; Petersen, Aaron; Harvey, Jack; Nichols, David; Aisbett, Brad
2012-05-01
Wildfire fighters are known to report to work in a hypohydrated state, which may compromise their work performance and health. To evaluate whether ingesting a bolus of fluid before the shift had any effect on firefighters' fluid consumption, core temperature, or the time they spent in high heart rate and work activity zones when fighting emergency wildfires. Thirty-two firefighters were divided into non-bolus (AD) and pre-shift drinking bolus (PS, 500 ml water) groups. Firefighters began work hypohydrated as indicated by urine colour, specific gravity and plasma osmolality (P(osm)) results. Post-shift, firefighters were classified as euhydrated according to P(osm) and hypohydrated by urinary markers. No significant differences existed between the drinking groups in pre- or post-shift hydration status, total fluid intake, activity, heart rate or core temperature. Consuming a bolus of fluid, pre-shift provided no benefit over non-consumption as both groups had consumed equivalent ad libitum volumes of fluid, 2.5 h into the shift. No benefits of bolus consumption were observed in firefighter activity, heart rate response or core temperature response across the shift in the mild weather conditions experienced. Ad libitum drinking was adequate to facilitate rehydration in firefighters upon completion of their emergency firefighting work shift. Copyright © 2011 Elsevier Ltd and The Ergonomics Society. All rights reserved.
Flow accelerated organic coating degradation
NASA Astrophysics Data System (ADS)
Zhou, Qixin
Applying organic coatings is a common and the most cost effective way to protect metallic objects and structures from corrosion. Water entry into coating-metal interface is usually the main cause for the deterioration of organic coatings, which leads to coating delamination and underfilm corrosion. Recently, flowing fluids over sample surface have received attention due to their capability to accelerate material degradation. A plethora of works has focused on the flow induced metal corrosion, while few studies have investigated the flow accelerated organic coating degradation. Flowing fluids above coating surface affect corrosion by enhancing the water transport and abrading the surface due to fluid shear. Hence, it is of great importance to understand the influence of flowing fluids on the degradation of corrosion protective organic coatings. In this study, a pigmented marine coating and several clear coatings were exposed to the laminar flow and stationary immersion. The laminar flow was pressure driven and confined in a flow channel. A 3.5 wt% sodium chloride solution and pure water was employed as the working fluid with a variety of flow rates. The corrosion protective properties of organic coatings were monitored inline by Electrochemical Impedance Spectroscopy (EIS) measurement. Equivalent circuit models were employed to interpret the EIS spectra. The time evolution of coating resistance and capacitance obtained from the model was studied to demonstrate the coating degradation. Thickness, gloss, and other topography characterizations were conducted to facilitate the assessment of the corrosion. The working fluids were characterized by Fourier Transform Infrared Spectrometer (FTIR) and conductivity measurement. The influence of flow rate, fluid shear, fluid composition, and other effects in the coating degradation were investigated. We conclude that flowing fluid on the coating surface accelerates the transport of water, oxygen, and ions into the coating, as well as promotes the migration of coating materials from the coating into the working fluid, where coatings experience more severe deterioration in their barrier property under flowing conditions. Pure water has shown to be a much more aggressive working fluid than electrolyte solutions. The flowing fluid over the coating surface could be used as an effective acceleration method.
Bio-inspired device: a novel smart MR spring featuring tendril structure
NASA Astrophysics Data System (ADS)
Kaluvan, Suresh; Park, Chun-Yong; Choi, Seung-Bok
2016-01-01
Smart materials such as piezoelectric patches, shape memory alloy, electro and magneto rheological fluid, magnetostrictive materials, etc are involved by far to design intelligent and high performance smart devices like injectors, dental braces, dampers, actuators and sensors. In this paper, an interesting smart device is proposed by inspiring on the structure of the bio climber plant. The key enabling concept of this proposed work is to design the smart spring damper as a helical shaped tendril structure using magneto-rheological (MR) fluid. The proposed smart spring consists of a hollow helical structure filled with MR fluid. The viscosity of the MR fluid decides the damping force of helical shaped smart spring, while the fluid intensity in the vine decides the strength of the tendril in the climber plant. Thus, the proposed smart spring can provide a new concept design of the damper which can be applicable to various damping system industries with tuneable damping force. The proposed smart spring damper has several advantageous such as cost effective, easy implementation compared with the conventional damper. In addition, the proposed spring damper can be easily designed to adapt different damping force levels without any alteration.
Nanofluid heat transfer under mixed convection flow in a tube for solar thermal energy applications.
Sekhar, Y Raja; Sharma, K V; Kamal, Subhash
2016-05-01
The solar flat plate collector operating under different convective modes has low efficiency for energy conversion. The energy absorbed by the working fluid in the collector system and its heat transfer characteristics vary with solar insolation and mass flow rate. The performance of the system is improved by reducing the losses from the collector. Various passive methods have been devised to aid energy absorption by the working fluid. Also, working fluids are modified using nanoparticles to improve the thermal properties of the fluid. In the present work, simulation and experimental studies are undertaken for pipe flow at constant heat flux boundary condition in the mixed convection mode. The working fluid at low Reynolds number in the mixed laminar flow range is undertaken with water in thermosyphon mode for different inclination angles of the tube. Local and average coefficients are determined experimentally and compared with theoretical values for water-based Al2O3 nanofluids. The results show an enhancement in heat transfer in the experimental range with Rayleigh number at higher inclinations of the collector tube for water and nanofluids.
Heat pump/refrigerator using liquid working fluid
Wheatley, John C.; Paulson, Douglas N.; Allen, Paul C.; Knight, William R.; Warkentin, Paul A.
1982-01-01
A heat transfer device is described that can be operated as a heat pump or refrigerator, which utilizes a working fluid that is continuously in a liquid state and which has a high temperature-coefficient of expansion near room temperature, to provide a compact and high efficiency heat transfer device for relatively small temperature differences as are encountered in heating or cooling rooms or the like. The heat transfer device includes a pair of heat exchangers that may be coupled respectively to the outdoor and indoor environments, a regenerator connecting the two heat exchangers, a displacer that can move the liquid working fluid through the heat exchangers via the regenerator, and a means for alternately increasing and decreasing the pressure of the working fluid. The liquid working fluid enables efficient heat transfer in a compact unit, and leads to an explosion-proof smooth and quiet machine characteristic of hydraulics. The device enables efficient heat transfer as the indoor-outdoor temperature difference approaches zero, and enables simple conversion from heat pumping to refrigeration as by merely reversing the direction of a motor that powers the device.
A Wireless Fluid-Level Measurement Technique
NASA Technical Reports Server (NTRS)
Woodard, Stanley E.; Taylor, Bryant D.
2006-01-01
This paper presents the application of a recently developed wireless measurement acquisition system to fluid-level measurement. This type of fluid-level measurement system alleviates many shortcomings of fluid-level measurement methods currently being used, including limited applicability of any one fluid-level sensor design. Measurement acquisition shortcomings include the necessity for power to be supplied to each sensor and for the measurement to be extracted from each sensor via a physical connection to the sensor. Another shortcoming is existing measurement systems require that a data channel and signal conditioning electronics be dedicated to each sensor. Use of wires results in other shortcomings such as logistics needed to add or replace sensors, weight, potential for electrical arcing and wire degradations. The fluid level sensor design is a simple passive inductor-capacitor circuit that is not subject to mechanical failure that is possible when float and lever-arm systems are used. Methods are presented for using the sensor in caustic, acidic or cryogenic fluids. Oscillating magnetic fields are used to power the sensor. Once electrically excited, the sensor produces a magnetic field response. The response frequency corresponds to the amount to fluid within the capacitor s electric field. The sensor design can be modified for measuring the level of any fluid or fluent substance that can be stored in a non-conductive reservoir. The interrogation method for discerning changes in the sensor response frequency is also presented.
Experimental Evaluation of Equivalent-Fluid Models for Melamine Foam
NASA Technical Reports Server (NTRS)
Allen, Albert R.; Schiller, Noah H.
2016-01-01
Melamine foam is a soft porous material commonly used in noise control applications. Many models exist to represent porous materials at various levels of fidelity. This work focuses on rigid frame equivalent fluid models, which represent the foam as a fluid with a complex speed of sound and density. There are several empirical models available to determine these frequency dependent parameters based on an estimate of the material flow resistivity. Alternatively, these properties can be experimentally educed using an impedance tube setup. Since vibroacoustic models are generally sensitive to these properties, this paper assesses the accuracy of several empirical models relative to impedance tube measurements collected with melamine foam samples. Diffuse field sound absorption measurements collected using large test articles in a laboratory are also compared with absorption predictions determined using model-based and measured foam properties. Melamine foam slabs of various thicknesses are considered.
Temperature and pressure effects on capacitance probe cryogenic liquid level measurement accuracy
NASA Technical Reports Server (NTRS)
Edwards, Lawrence G.; Haberbusch, Mark
1993-01-01
The inaccuracies of liquid nitrogen and liquid hydrogen level measurements by use of a coaxial capacitance probe were investigated as a function of fluid temperatures and pressures. Significant liquid level measurement errors were found to occur due to the changes in the fluids dielectric constants which develop over the operating temperature and pressure ranges of the cryogenic storage tanks. The level measurement inaccuracies can be reduced by using fluid dielectric correction factors based on measured fluid temperatures and pressures. The errors in the corrected liquid level measurements were estimated based on the reported calibration errors of the temperature and pressure measurement systems. Experimental liquid nitrogen (LN2) and liquid hydrogen (LH2) level measurements were obtained using the calibrated capacitance probe equations and also by the dielectric constant correction factor method. The liquid levels obtained by the capacitance probe for the two methods were compared with the liquid level estimated from the fluid temperature profiles. Results show that the dielectric constant corrected liquid levels agreed within 0.5 percent of the temperature profile estimated liquid level. The uncorrected dielectric constant capacitance liquid level measurements deviated from the temperature profile level by more than 5 percent. This paper identifies the magnitude of liquid level measurement error that can occur for LN2 and LH2 fluids due to temperature and pressure effects on the dielectric constants over the tank storage conditions from 5 to 40 psia. A method of reducing the level measurement errors by using dielectric constant correction factors based on fluid temperature and pressure measurements is derived. The improved accuracy by use of the correction factors is experimentally verified by comparing liquid levels derived from fluid temperature profiles.
Variable pressure power cycle and control system
Goldsberry, Fred L.
1984-11-27
A variable pressure power cycle and control system that is adjustable to a variable heat source is disclosed. The power cycle adjusts itself to the heat source so that a minimal temperature difference is maintained between the heat source fluid and the power cycle working fluid, thereby substantially matching the thermodynamic envelope of the power cycle to the thermodynamic envelope of the heat source. Adjustments are made by sensing the inlet temperature of the heat source fluid and then setting a superheated vapor temperature and pressure to achieve a minimum temperature difference between the heat source fluid and the working fluid.
Corey, John A.
1985-01-01
A multi-cylinder hot gas engine having an equal angle, V-shaped engine block in which two banks of parallel, equal length, equally sized cylinders are formed together with annular regenerator/cooler units surrounding each cylinder, and wherein the pistons are connected to a single crankshaft. The hot gas engine further includes an annular heater head disposed around a central circular combustor volume having a new balanced-flow hot-working-fluid manifold assembly that provides optimum balanced flow of the working fluid through the heater head working fluid passageways which are connected between each of the cylinders and their respective associated annular regenerator units. This balanced flow provides even heater head temperatures and, therefore, maximum average working fluid temperature for best operating efficiency with the use of a single crankshaft V-shaped engine block.
ERIC Educational Resources Information Center
Haavisto, Marja-Leena; Lehto, Juhani E.
2005-01-01
Fluid/spatial intelligence, crystallized intelligence and their relationships to verbal and visuospatial working memory (WM) were studied. A total of 120 Finnish Air Force recruits participated in this study. Fluid/spatial intelligence was assessed using four different tasks, while crystallized intelligence was defined with the help of test scores…
NASA Technical Reports Server (NTRS)
Gulino, D. A.; Coles, C. E.
1986-01-01
The Liquid Droplet Radiator is one of several radiator systems currently under investigation by NASA Lewis Research Center. It involves the direct exposure of the radiator working fluid to the space environment. An area of concern is the potential harmful effects of the low-Earth-orbit atomic oxygen environment on the radiator working fluid. To address this issue, seven candidate fluids were exposed to an oxygen plasma environment in a laboratory plasma asher. The fluids studied included Dow Corning 705 Diffusion Pump Fluid, polymethylphenylsiloxane and polydimethlsiloxane, both of which are experimental fluids made by Dow Corning, Fomblin Z25, made by Montedison, and three fluids from the Krytox family of fluids, Krytox 143AB, 1502, and 16256, which are made by DuPont. The fluids were characterized by noting changes in visual appearance, physical state, mass, and infrared spectra. Of the fluids tested, the Fomblin and the three Krytoxes were the least affected by the oxygen plasma. The only effect noted was a change in mass, which was most likely due to an oxygen-catalyzed deploymerization of the fluid molecule.
Is downer cow syndrome related to chronic botulism?
Rulff, R; Schrödl, W; Basiouni, S; Neuhaus, J; Krüger, M
2015-01-01
The present work was directed to investigate the relationship between Downer cow syndrome (DCS) and chronic botulism in dairy cattle. For this purpose, a total of 52 fresh calving downer cows and 206 apparently healthy cows at 14 dairy farms were investigated for Clostridium botulinum ABE and CD antibody levels, C. botulinum and botulinum neurotoxin in rumen fluids as well as in faeces. Results indicated that the downer cows had higher IgG titers for C. botulinum ABE and CD than the healthy cows. All tested rumen fluids were negative for BoNT and C. botulinum. BoNT/D, however, and C. botulinum type D spores were detected in faecal samples of healthy and downer cows in the selected farms. In conclusion, the presence of a significantly higher C. botulinum ABE and CD antibody levels in DCS cows than in the healthy animals suggests that chronic C. botulinum toxico-infection could be a predisposing factor for DCS.
Pradeep, Avani Raju; Nagpal, Kanika; Karvekar, Shruti; Patnaik, Kaushik
2016-11-01
Lipocalin-2, a 25 kDa secretory glycoprotein, was first found in the neutrophilic granules of humans and in mouse kidney cells. It has been shown to have an important role in inflammation. The aim of this study was to determine the levels of lipocalin-2 in gingival crevicular fluid and tear fluid in patients with obesity and chronic periodontitis. A total of 40 subjects in the age group 25-40 years were divided into four groups based on probing depth, gingival index, clinical attachment level, body mass index, and radiographic evidence of bone loss. The groups were: nonobese healthy group; obese healthy group; nonobese chronic periodontitis group; obese chronic periodontitis group Gingival crevicular fluid and tear fluid samples were collected on the subsequent day. There was an increase in lipocalin-2 levels from group 1 to group 4 (with the nonobese healthy group showing the least levels and obese chronic periodontitis group showing the highest levels) in both gingival crevicular fluid and tear fluid. Lipocalin-2 may be an important inflammatory marker that may help link obesity and chronic periodontitis. © 2015 Wiley Publishing Asia Pty Ltd.
Thermal Analysis of Nanofluids Using Modeling and Molecular Dynamics Simulation
NASA Astrophysics Data System (ADS)
Namboori, P. K. Krishnan; Vasavi, C. S.; Gopal, K. Varun; Gopakumar, Deepa; Ramachandran, K. I.; Narayanan, B. Sabarish
2010-10-01
Nanofluids are nanotechnology-based heat transfer fluids obtained by suspending nanometer-sized particles in conventional heat transfer fluids in a stable manner. In many of the physical phenomena such as boiling and properties such as latent heat, thermal conductivity and heat transfer coefficient, there is significant change on addition of nanoparticles. These exceptional qualities of Nanofluids mainly depend on the atomic level mechanisms, which in turn govern all mechanical properties like strength, Young's modulus, Poisson's ratio, compressibility etc. Control over the fundamental thermo physical properties of the working medium will help to understand these unique phenomena of nanofluids to a great extent. Macroscopic modeling approaches, which are based on conventional relations of thermodynamics, have been proved to be incompetent to explain this difference. Atomistic `modeling and simulation' has been emerged out as an efficient alternative for this. The enhancement of thermal conductivity of water by suspending nanoparticle inclusions has been experimented and proved to be an effective method of enhancing convective heat dissipation. This work mainly deals with characterization of the thermal conductivity of nanofluids. Nano particle sized aluminium oxide; copper oxide and titanium dioxide have been taken in this work for the analysis of thermal conductivity. The effect of thermal conductivity on parameters like volume concentration of the fluid, nature of particle material and size of the particle has been computationally formulated. It has been found that there is an increase in effective thermal conductivity of the fluid by the addition of nanomaterials ascertaining an improvement in the heat transfer behavior of nanofluids. This facilitates the reduction in size of such heat transfer systems (radiators) and lead to increased energy and fuel efficiency, lower pollution and improved reliability.
... the tiny working units of the kidneys that filter wastes and remove extra fluid from the blood. ... the tiny working units of the kidneys that filter wastes and remove extra fluid from the blood. ...
Factors influencing the restoration of fluid and electrolyte balance after exercise in the heat.
Maughan, R J; Leiper, J B; Shirreffs, S M
1997-01-01
Maintenance of fluid balance is a major concern for all athletes competing in events held in hot climates. This paper reviews recent work relating to optimisation of fluid replacement after sweat loss induced by exercising in the heat. Data are taken from studies undertaken in our laboratory. Issues investigated were drink composition, volume consumed, effects of consuming food with a drink, effects of alcohol in rehydration effectiveness, voluntary intake of fluid, and considerations for women related to the menstrual cycle. The results are presented as a series of summaries of experiments, followed by a discussion of the implications. The focus of this review is urine output after ingestion of a drink; fluid excreted in urine counteracts rehydration. Also included are data on the restoration of plasma volume losses. Ingestion of large volumes of plain water will inhibit thirst and will also promote a diuretic response. If effective rehydration is to be maintained for some hours after fluid ingestion, drinks should contain moderately high levels of sodium (perhaps as much as 50-60 mmol/l) and possibly also some potassium to replace losses in the sweat. To surmount ongoing obligatory urine losses, the volume consumed should be greater than the volume of sweat lost. Palatability of drinks is important in stimulating intake and ensuring adequate volume replacement. Where opportunities allow, the electrolytes required may be ingested as solid food consumed with a drink. There are no special concerns for women related to changes in hormone levels associated with the menstrual cycle. Ingestion of carbohydrate-electrolyte drinks in the post-exercise period restores exercise capacity more effectively than plain water. The effects on performance of an uncorrected fluid deficit should persuade all athletes to attempt to remain fully hydrated at all times, and the aim should be to start each bout of exercise in a fluid replete state. This will only be achieved if a volume of fluid in excess of the sweat loss is ingested together with sufficient electrolytes. PMID:9298549
NASA Technical Reports Server (NTRS)
Convertino, V. A.; Engelke, K. A.; Ludwig, D. A.; Doerr, D. F.
1996-01-01
Seven healthy men performed maximal exercise 24 h before the end of 16 days exposure to 6 degrees head-down tilt (HDT) to test the hypothesis that such an exercise technique could restore plasma volume (PV) at the end of a simulated space mission. Exercise consisted of supine cycling with graded work rates increasing by 16 W/min to volitional fatigue and required an average of 16 min. The experimental protocol was a standard cross-over design in which the order of treatment (exercise or control) was counterbalanced across all seven subjects. PV, fluid intake (ad libitum), urine output, renal function, and hormones associated with fluid homeostasis were measured before HDT, 24 h before the end of HDT just prior to exercise, and at the end of HDT 24 h after exercise. HDT reduced PV by 16% in both control and exercise conditions. Maximal exercise completely restored plasma volume within 24 h to 3.9 +/- 3.2% of pre-HDT levels despite continued HDT. Compared with control, exercise induced a 660-ml larger positive fluid balance because of greater fluid intake and reduced urine volume during the 24 h after exercise. These results suggest that one bout of maximal leg exercise before return from 16 days of spaceflight may be completely effective in stimulating thirst and restoring plasma volume to preflight levels.
Mizutani, Tatsushi; Yoshimoto, Takashi; Ishii, Akira
2018-05-21
We examined postmortem β-hydroxybutyrate (BHB) levels in the body fluids obtained from 253 forensic autopsy cases whose causes of death were determined. Postmortem changes of BHB levels according to postmortem intervals (PMI) in various body fluids (plasma, urine, vitreous humor, and pericardial fluids) were investigated to determine appropriate alternative specimens as plasma samples. Our study has indicated the following points: 1) the BHB levels in plasma specimens from three sampling sites showed no significant differences, 2) postmortem changes of BHB levels in plasma and pericardial fluids could be negligible within 96 h PMI, while urine and vitreous humor BHB levels showed postmortem changes, and 3) pericardial fluid would thus be most suitable as an alternative to plasma in postmortem BHB level. We have also proposed that BHB levels could be applicable for the diagnosis of metabolic disorders in forensic autopsy. Copyright © 2018 Elsevier B.V. All rights reserved.
Watanabe, Shoji
2008-01-01
This short review describes various types of anti-corrosion additives of water-soluble metal working fluids for aluminum alloy materials. It is concerned with synthetic additives classified according to their functional groups; silicone compounds, carboxylic acids and dibasic acids, esters, Diels-Alder adducts, various polymers, nitrogen compounds, phosphoric esters, phosphonic acids, and others. Testing methods for water-soluble metal working fluids for aluminum alloy materials are described for a practical application in a laboratory.
Water-saving liquid-gas conditioning system
Martin, Christopher; Zhuang, Ye
2014-01-14
A method for treating a process gas with a liquid comprises contacting a process gas with a hygroscopic working fluid in order to remove a constituent from the process gas. A system for treating a process gas with a liquid comprises a hygroscopic working fluid comprising a component adapted to absorb or react with a constituent of a process gas, and a liquid-gas contactor for contacting the working fluid and the process gas, wherein the constituent is removed from the process gas within the liquid-gas contactor.
The role of brain barriers in fluid movement in the CNS: is there a 'glymphatic' system?
Abbott, N Joan; Pizzo, Michelle E; Preston, Jane E; Janigro, Damir; Thorne, Robert G
2018-03-01
Brain fluids are rigidly regulated to provide stable environments for neuronal function, e.g., low K + , Ca 2+ , and protein to optimise signalling and minimise neurotoxicity. At the same time, neuronal and astroglial waste must be promptly removed. The interstitial fluid (ISF) of the brain tissue and the cerebrospinal fluid (CSF) bathing the CNS are integral to this homeostasis and the idea of a glia-lymph or 'glymphatic' system for waste clearance from brain has developed over the last 5 years. This links bulk (convective) flow of CSF into brain along the outside of penetrating arteries, glia-mediated convective transport of fluid and solutes through the brain extracellular space (ECS) involving the aquaporin-4 (AQP4) water channel, and finally delivery of fluid to venules for clearance along peri-venous spaces. However, recent evidence favours important amendments to the 'glymphatic' hypothesis, particularly concerning the role of glia and transfer of solutes within the ECS. This review discusses studies which question the role of AQP4 in ISF flow and the lack of evidence for its ability to transport solutes; summarizes attributes of brain ECS that strongly favour the diffusion of small and large molecules without ISF flow; discusses work on hydraulic conductivity and the nature of the extracellular matrix which may impede fluid movement; and reconsiders the roles of the perivascular space (PVS) in CSF-ISF exchange and drainage. We also consider the extent to which CSF-ISF exchange is possible and desirable, the impact of neuropathology on fluid drainage, and why using CSF as a proxy measure of brain components or drug delivery is problematic. We propose that new work and key historical studies both support the concept of a perivascular fluid system, whereby CSF enters the brain via PVS convective flow or dispersion along larger caliber arteries/arterioles, diffusion predominantly regulates CSF/ISF exchange at the level of the neurovascular unit associated with CNS microvessels, and, finally, a mixture of CSF/ISF/waste products is normally cleared along the PVS of venules/veins as well as other pathways; such a system may or may not constitute a true 'circulation', but, at the least, suggests a comprehensive re-evaluation of the previously proposed 'glymphatic' concepts in favour of a new system better taking into account basic cerebrovascular physiology and fluid transport considerations.
Precision Clean Hardware: Maintenance of Fluid Systems Cleanliness
NASA Technical Reports Server (NTRS)
Sharp, Sheila; Pedley, Mike; Bond, Tim; Quaglino, Joseph; Lorenz, Mary Jo; Bentz, Michael; Banta, Richard; Tolliver, Nancy; Golden, John; Levesque, Ray
2003-01-01
The ISS fluid systems are so complex that fluid system cleanliness cannot be verified at the assembly level. A "build clean / maintain clean" approach was used by all major fluid systems: Verify cleanliness at the detail and subassembly level. Maintain cleanliness during assembly.
Clark, Cameron M; Lawlor-Savage, Linette; Goghari, Vina M
2017-01-01
Training of working memory as a method of increasing working memory capacity and fluid intelligence has received much attention in recent years. This burgeoning field remains highly controversial with empirically-backed disagreements at all levels of evidence, including individual studies, systematic reviews, and even meta-analyses. The current study investigated the effect of a randomized six week online working memory intervention on untrained cognitive abilities in a community-recruited sample of healthy young adults, in relation to both a processing speed training active control condition, as well as a no-contact control condition. Results of traditional null hypothesis significance testing, as well as Bayesian factor analyses, revealed support for the null hypothesis across all cognitive tests administered before and after training. Importantly, all three groups were similar at pre-training for a variety of individual variables purported to moderate transfer of training to fluid intelligence, including personality traits, motivation to train, and expectations of cognitive improvement from training. Because these results are consistent with experimental trials of equal or greater methodological rigor, we suggest that future research re-focus on: 1) other promising interventions known to increase memory performance in healthy young adults, and; 2) examining sub-populations or alternative populations in which working memory training may be efficacious.
Water intake reverses dehydration associated impaired executive function in healthy young women.
Stachenfeld, Nina S; Leone, Cheryl A; Mitchell, Ellen S; Freese, Eric; Harkness, Laura
2018-03-01
Healthy women do not always consume Recommended Daily Levels of fluid intake ad libitum. We hypothesized that 1) women lose≥1.0% BW during daily activities, 2) that mild body water loss impairs memory and executive function, 3) water intake to recommended daily levels will improve cognitive function. We tested 12 women (26±5yr, 22.5±2.6kg/m 2 BMI). Session 1 was a control (CON) session, during which subjects monitored their food and fluid intake (diary) and activity (Fitbit®). The next two sessions were applied in balanced order: dehydration (DEH) session, where subjects minimized drinking, and a euhydration (EUH) session, where subjects drank Recommended Daily Levels of fluid for their age and sex, or 2500ml/24h. We compared emotion, sensory perception and cognition with computer based visual analog tests and computer based cognitive tasks (Cogstate) at 5PM, i.e. baseline (BL) on the evening prior to the session, and at 7AM, 12PM, and 5PM during the session. Urine specific gravity (USG) was similar at BL across conditions (CON 1.013±0.002, DEH 1.015±0.002, EUH 1.014±0.002) and increased with dehydration (CON 1.011±0.003, DEH 1.021±0.002, EUH 1.010±0.002, P<0.05) by 5PM of the session. Uncontrolled fluid intake and physical activity were similar across sessions. The water challenges did not impact Detection, Identification, One-Card Learning, but EUH improved visual and working memory (Groton Maze Learning Test) errors: CON 40.1±11.1, DEH 40.5±10.1, EUH 33.9±10.9, P<0.05. Executive function [Set Shifting (SETS)] also improved under EUH, errors: BL 22.5±12.7 vs. 5PM 17.8±6.2, P<0.05. Mild dehydration caused deficits in visual and working memory and executive function in healthy young women. These deficits were reversed by drinking water to the European Food Safety Authority and Institute of Medicine requirements of 2.5l/day for adult women. Copyright © 2017 Elsevier Inc. All rights reserved.
Interactions Between DNA and Actin in Model Cystic Fibrosis Sputum
NASA Astrophysics Data System (ADS)
Kyung, Hee; Sanders, Lori; Angelini, Thomas; Butler, John; Wong, Gerard
2003-03-01
Cystic fibrosis sputum is a complex fluid which has a high concentration of DNA and F-actin, two anionic biological polyelectrolytes. In this work, we study the interactions between DNA and actin in an aqueous environment over a wide range of polyelectrolyte lengths and salt levels, using synchrotron Small Angle X-ray Scattering(SAXS) and confocal microscopy. Perliminary results indicate the existence of a compressed phase of nematic F-actin in the presence of DNA. This work was supported by NSF DMR-0071761, the Beckman Young Investigator Program, and the Cystic Fibrosis Foundation.
Working Memory Training Does Not Improve Intelligence in Healthy Young Adults
ERIC Educational Resources Information Center
Chooi, Weng-Tink; Thompson, Lee A.
2012-01-01
Jaeggi and her colleagues claimed that they were able to improve fluid intelligence by training working memory. Subjects who trained their working memory on a dual n-back task for a period of time showed significant improvements in working memory span tasks and fluid intelligence tests such as the Raven's Progressive Matrices and the Bochumer…
Versatile fluid-mixing device for cell and tissue microgravity research applications.
Wilfinger, W W; Baker, C S; Kunze, E L; Phillips, A T; Hammerstedt, R H
1996-01-01
Microgravity life-science research requires hardware that can be easily adapted to a variety of experimental designs and working environments. The Biomodule is a patented, computer-controlled fluid-mixing device that can accommodate these diverse requirements. A typical shuttle payload contains eight Biomodules with a total of 64 samples, a sealed containment vessel, and a NASA refrigeration-incubation module. Each Biomodule contains eight gas-permeable Silastic T tubes that are partitioned into three fluid-filled compartments. The fluids can be mixed at any user-specified time. Multiple investigators and complex experimental designs can be easily accommodated with the hardware. During flight, the Biomodules are sealed in a vessel that provides two levels of containment (liquids and gas) and a stable, investigator-controlled experimental environment that includes regulated temperature, internal pressure, humidity, and gas composition. A cell microencapsulation methodology has also been developed to streamline launch-site sample manipulation and accelerate postflight analysis through the use of fluorescent-activated cell sorting. The Biomodule flight hardware and analytical cell encapsulation methodology are ideally suited for temporal, qualitative, or quantitative life-science investigations.
Ratchet flow of thin liquid films induced by a two-frequency tangential forcing
NASA Astrophysics Data System (ADS)
Sterman-Cohen, Elad; Bestehorn, Michael; Oron, Alexander
2018-02-01
A possibility of saturating Rayleigh-Taylor instability in a thin liquid film on the underside of a substrate in the gravity field by harmonic vibration of the substrate was recently investigated [E. Sterman-Cohen, M. Bestehorn, and A. Oron, Phys. Fluids 29, 052105 (2017); Erratum, Phys. Fluids 29, 109901 (2017)]. In the present work, we investigate the feasibility of creating a directional flow of the fluid in a film in the Rayleigh-Taylor configuration and controlling its flow rate by applying a two-frequency tangential forcing to the substrate. It is shown that in this situation, a ratchet flow develops, and the dependence of its flow rate on the vibration frequency, amplitude, its periodicity, and asymmetry level is investigated for water and silicone-oil films. A cause for the emergence of symmetry-breaking and an ensuing flow in a preferred direction is discussed. Some aspects of a ratchet flow in a liquid film placed on top of the substrate are discussed as well. A comparison with the case of a neglected fluid inertia is made, and the differences are explained.
Improvement of the limit torque for the torque limiter with magnetic rheological fluid
NASA Astrophysics Data System (ADS)
Umehara, Noritsugu; Kita, Shizuo
Robots are coming to support and help our life. The robots that work together with human need to avoid sever hitting and holding that force is more than the adequate and comfortable range. In order to keep the force to the safe level in the robot arms, t he limit torque should be controlled on the basis of the case the robot used. Magnetic rheological fluids were tried to be used for the clutch that transmission torque can be controlled continuously because MR fluids can be controlled its viscosity by magnetic field. However those clutch devices were too heavy and large to use for the robot arms. Therefore we tried to increase the sensitivity of magnetic field to viscosity of MR fluids. By applying rough surface for the mating surface, sensitivity of the magnetic field to the shearing torque increase drastically in the case of co-axial torque meter. On the other hand, the changing of the size of the orifice is effective to increase the sensitivity of the magnetic field on the flow resistance in the case of the orifice type equipment.
A discontinuous Galerkin conservative level set scheme for interface capturing in multiphase flows
DOE Office of Scientific and Technical Information (OSTI.GOV)
Owkes, Mark, E-mail: mfc86@cornell.edu; Desjardins, Olivier
2013-09-15
The accurate conservative level set (ACLS) method of Desjardins et al. [O. Desjardins, V. Moureau, H. Pitsch, An accurate conservative level set/ghost fluid method for simulating turbulent atomization, J. Comput. Phys. 227 (18) (2008) 8395–8416] is extended by using a discontinuous Galerkin (DG) discretization. DG allows for the scheme to have an arbitrarily high order of accuracy with the smallest possible computational stencil resulting in an accurate method with good parallel scaling. This work includes a DG implementation of the level set transport equation, which moves the level set with the flow field velocity, and a DG implementation of themore » reinitialization equation, which is used to maintain the shape of the level set profile to promote good mass conservation. A near second order converging interface curvature is obtained by following a height function methodology (common amongst volume of fluid schemes) in the context of the conservative level set. Various numerical experiments are conducted to test the properties of the method and show excellent results, even on coarse meshes. The tests include Zalesak’s disk, two-dimensional deformation of a circle, time evolution of a standing wave, and a study of the Kelvin–Helmholtz instability. Finally, this novel methodology is employed to simulate the break-up of a turbulent liquid jet.« less
Heat transfer head for a Stirling cycle machine
NASA Technical Reports Server (NTRS)
Emigh, Stuart G. (Inventor); Noble, Jack E. (Inventor); Lehmann, Gregory A. (Inventor)
1991-01-01
A common heat acceptor is provided between opposed displacers in a Stirling cycle machine. It includes two sets of open channels in separate fluid communications with the expansion spaces of the receptive cyclinders. The channels confine movement of working fluid in separate paths that extend between the expansion space of one cylinder and the compression space of the other. The method for operating the machine involves alternatively directing working fluid from the expansion space of each cylinder in a fluid path leading to the compression space of the other cylinder and from the compression space of each cylinder in a fluid path leading to the expansion space of the other cylinder.
Cantón-Romero, Juan Carlos; Miranda-Díaz, Alejandra Guillermina; Bañuelos-Ramírez, Jose Luis; Carrillo-Ibarra, Sandra; Sifuentes-Franco, Sonia; Castellanos-González, José Alberto; Rodríguez-Carrizalez, Adolfo Daniel
2017-01-01
Diverse proinflammatory biomarkers and oxidative stress are strongly associated with advanced epithelial ovarian cancer (EOC). Objective . To determine the behavior of markers of oxidative stress and inflammation in plasma and ascites fluid in patients with platinum-sensitive, platinum-resistant, and platinum-refractory EOC. Methods . A prospective cohort study. The colorimetric method was used to determine levels of the markers 8-isoprostanes (8-IP), lipid peroxidation products (LPO), and total antioxidant capacity (TAC) in plasma and ascites fluid; and with ELISA, the levels of interleukin-6 (IL-6) and tumor necrosis factor alpha (TNF- α ) were determined in patients with EOC. Results . In ascites fluid, a significant increase in 8-IP versus baseline plasma levels was found ( p = 0.002). There was an important leakage of the TAC levels in ascites fluid versus baseline plasma levels ( p < 0.001). The IL-6 was elevated in ascites fluid versus baseline plasma levels ( p = 0.003), and there were diminished levels of TNF- α in ascites fluid versus baseline plasma levels ( p = 0.001). Discussion . We hypothesize that the ascites fluid influences the behavior and dissemination of the tumor. Deregulation between oxidants, antioxidants, and the proinflammatory cytokines was found to vary among platinum-sensitive, platinum-resistant, and platinum-refractory patients.
Systems evaluation of thermal bus concepts
NASA Technical Reports Server (NTRS)
Stalmach, D. D.
1982-01-01
Thermal bus concepts, to provide a centralized thermal utility for large, multihundred kilowatt space platforms, were studied and the results are summarized. Concepts were generated, defined, and screened for inclusion in system level thermal bus trades. Parametric trade studies were conducted in order to define the operational envelope, performance, and physical characteristics of each. Two concepts were selected as offering the most promise for thermal bus development. All of four concepts involved two phase flow in order to meet the required isothermal nature of the thermal bus. Two of the concepts employ a mechanical means to circulate the working fluid, a liquid pump in one case and a vapor compressor in another. Another concept utilizes direct osmosis as the driving force of the thermal bus. The fourth concept was a high capacity monogroove heat pipe. After preliminary sizing and screening, three of these concepts were selected to carry into the trade studies. The monogroove heat pipe concept was deemed unsuitable for further consideration because of its heat transport limitations. One additional concept utilizing capillary forces to drive the working fluid was added. Parametric system level trade studies were performed. Sizing and weight calculations were performed for thermal bus sizes ranging from 5 to 350 kW and operating temperatures in the range of 4 to 120 C. System level considerations such as heat rejection and electrical power penalties and interface temperature losses were included in the weight calculations.
Greg.Glatzmaier@nrel.gov | 303-384-7470 Greg originally joined NREL in 1987 and worked in the Solar Thermal work on systems analysis, novel heat-transfer fluids, and thermal-storage concepts for CSP technologies . He currently manages the advanced heat-transfer fluids and thermal-storage work at NREL. Education
Method of calibrating a fluid-level measurement system
NASA Technical Reports Server (NTRS)
Woodard, Stanley E. (Inventor); Taylor, Bryant D. (Inventor)
2010-01-01
A method of calibrating a fluid-level measurement system is provided. A first response of the system is recorded when the system's sensor(s) is (are) not in contact with a fluid of interest. A second response of the system is recorded when the system's sensor(s) is (are) fully immersed in the fluid of interest. Using the first and second responses, a plurality of expected responses of the system's sensor(s) is (are) generated for a corresponding plurality of levels of immersion of the sensor(s) in the fluid of interest.
A review of research and development on the microwave-plasma electrothermal rocket
NASA Technical Reports Server (NTRS)
Hawley, Martin C.; Asmussen, Jes; Filpus, John W.; Frasch, Lydell L.; Whitehair, Stanley; Morin, T. J.; Chapman, R.
1987-01-01
The microwave-plasma electrothermal rocket (MWPETR) shows promise for spacecraft propulsion and maneuvering, without some of the drawbacks of competitive electric propulsion systems. In the MWPETR, the electric power is first converted to microwave-frequency radiation. In a specially-designed microwave cavity system, the electromagnetic energy of the radiation is transferred to the electrons in a plasma sustained in the working fluid. The resulting high-energy electrons transfer their energy to the atoms and molecules of the working fluid by collisions. The working fluid, thus heated, expands through a nozzle to generate thrust. In the MWPETR, no electrodes are in contact with the working fluid, the energy is transferred into the working fluid by nonthermal mechanisms, and the main requirement for the materials of construction is that the walls of the plasma chamber be insulating and transparent to microwave radiation at operating conditions. In this survey of work on the MWPETR, several experimental configurations are described and compared. Diagnostic methods used in the study are described and compared, including titration, spectroscopy, calorimetry, electric field measurements, gas-dynamic methods, and thrust measurements. Measured and estimated performance efficiencies are reported. Results of computer modeling of the plasma and of the gas flowing from the plasma are summarized.
NASA Astrophysics Data System (ADS)
Mahdavi, Mahboobe; Tiari, Saeed; Qiu, Songgang
2016-11-01
Heat pipes are two-phase heat transfer devices, which operate based on evaporation and condensation of a working fluid inside a sealed container. In the current work, an experimental study was conducted to investigate the performance of a copper-water heat pipe. The performance was evaluated by calculating the corresponding thermal resistance as the ratio of temperature difference between evaporator and condenser to heat input. The effects of inclination angle and the amount of working fluid were studied on the equivalent thermal resistance. The results showed that if the heat pipe is under-filled with the working fluid, energy transferring capacity of the heat pipe decreases dramatically. However, overfilling heat pipe causes over flood and degrades heat pipe performance. The minimum thermal resistances were obtained for the case that 30% of the heat pipe volume was filled with working fluid. It was also found that in gravity-assisted orientations, the inclination angle does not have significant effect on the performance of the heat pipe. However, for gravity-opposed orientations, as the inclination angle increases, the temperature difference between the evaporator and condensation increases and higher thermal resistances are obtained. Authors appreciate the financial support by a research Grant from Temple University.
Failure of Working Memory Training to Enhance Cognition or Intelligence
Thompson, Todd W.; Waskom, Michael L.; Garel, Keri-Lee A.; Cardenas-Iniguez, Carlos; Reynolds, Gretchen O.; Winter, Rebecca; Chang, Patricia; Pollard, Kiersten; Lala, Nupur; Alvarez, George A.; Gabrieli, John D. E.
2013-01-01
Fluid intelligence is important for successful functioning in the modern world, but much evidence suggests that fluid intelligence is largely immutable after childhood. Recently, however, researchers have reported gains in fluid intelligence after multiple sessions of adaptive working memory training in adults. The current study attempted to replicate and expand those results by administering a broad assessment of cognitive abilities and personality traits to young adults who underwent 20 sessions of an adaptive dual n-back working memory training program and comparing their post-training performance on those tests to a matched set of young adults who underwent 20 sessions of an adaptive attentional tracking program. Pre- and post-training measurements of fluid intelligence, standardized intelligence tests, speed of processing, reading skills, and other tests of working memory were assessed. Both training groups exhibited substantial and specific improvements on the trained tasks that persisted for at least 6 months post-training, but no transfer of improvement was observed to any of the non-trained measurements when compared to a third untrained group serving as a passive control. These findings fail to support the idea that adaptive working memory training in healthy young adults enhances working memory capacity in non-trained tasks, fluid intelligence, or other measures of cognitive abilities. PMID:23717453
Analysis of solar water heater with parabolic dish concentrator and conical absorber
NASA Astrophysics Data System (ADS)
Rajamohan, G.; Kumar, P.; Anwar, M.; Mohanraj, T.
2017-06-01
This research focuses on developing novel technique for a solar water heating system. The novel solar system comprises a parabolic dish concentrator, conical absorber and water heater. In this system, the conical absorber tube directly absorbs solar radiation from the sun and the parabolic dish concentrator reflects the solar radiations towards the conical absorber tube from all directions, therefore both radiations would significantly improve the thermal collector efficiency. The working fluid water is stored at the bottom of the absorber tubes. The absorber tubes get heated and increases the temperature of the working fluid inside of the absorber tube and causes the working fluid to partially evaporate. The partially vaporized working fluid moves in the upward direction due to buoyancy effect and enters the heat exchanger. When fresh water passes through the heat exchanger, temperature of the vapour decreases through heat exchange. This leads to condensation of the vapour and forms liquid phase. The working fluid returns to the bottom of the collector absorber tube by gravity. Hence, this will continue as a cyclic process inside the system. The proposed investigation shows an improvement of collector efficiency, enhanced heat transfer and a quality water heating system.
Recovery of energy from geothermal brine and other hot water sources
Wahl, III, Edward F.; Boucher, Frederic B.
1981-01-01
Process and system for recovery of energy from geothermal brines and other hot water sources, by direct contact heat exchange between the brine or hot water, and an immiscible working fluid, e.g. a hydrocarbon such as isobutane, in a heat exchange column, the brine or hot water therein flowing countercurrent to the flow of the working fluid. The column can be operated at subcritical, critical or above the critical pressure of the working fluid. Preferably, the column is provided with a plurality of sieve plates, and the heat exchange process and column, e.g. with respect to the design of such plates, number of plates employed, spacing between plates, area thereof, column diameter, and the like, are designed to achieve maximum throughput of brine or hot water and reduction in temperature differential at the respective stages or plates between the brine or hot water and the working fluid, and so minimize lost work and maximize efficiency, and minimize scale deposition from hot water containing fluid including salts, such as brine. Maximum throughput approximates minimum cost of electricity which can be produced by conversion of the recovered thermal energy to electrical energy.
NASA Astrophysics Data System (ADS)
Douvartzides, S.; Karmalis, I.
2016-11-01
Organic Rankine cycle technology is capable to efficiently convert low-grade heat into useful mechanical power. In the present investigation such a cycle is used for the recovery of heat from the exhaust gases of a four stroke V18 MAN 51/60DF internal combustion engine power plant operating with natural gas. Design is focused on the selection of the appropriate working fluid of the Rankine cycle in terms of thermodynamic, environmental and safety criteria. 37 candidate fluids have been considered and all Rankine cycles examined were subcritical. The thermodynamic analysis of all fluids has been comparatively undertaken and the effect of key operation conditions such as the evaporation pressure and the superheating temperature was taken into account. By appropriately selecting the working fluid and the Rankine cycle operation conditions the overall plant efficiency was improved by 5.52% and fuel consumption was reduced by 12.69%.
Thermal Effects on the "Ice-Cube Puzzle"
ERIC Educational Resources Information Center
Lima, F. M. S.; Monteiro, F. F.
2012-01-01
When an ice cube floating on water in a container melts, it is said in some textbooks that the water level does not change. However, as pointed out by Lan in a recent work, when the buoyant force from a less dense fluid resting above the waterline is taken into account, one should expect a detectable "increase" in the volume of water. Here in this…
Heat pipe temperature control utilizing a soluble gas absorption reservior
NASA Technical Reports Server (NTRS)
Saaski, E. W.
1976-01-01
A new gas-controlled heat pipe design is described which uses a liquid matrix reservior, or sponge, to replace the standard gas reservior. Reservior volume may be reduced by a factor of five to ten for certain gas-liquid combinations, while retaining the same level of temperature control. Experiments with ammonia, butane, and carbon dioxide control gases with methanol working fluid are discussed.
Borovcová, Lucie; Pauk, Volodymyr; Lemr, Karel
2018-05-01
New psychoactive substances represent serious social and health problem as tens of new compounds are detected in Europe annually. They often show structural proximity or even isomerism, which complicates their analysis. Two methods based on ultra high performance supercritical fluid chromatography and ultra high performance liquid chromatography with mass spectrometric detection were validated and compared. A simple dilute-filter-and-shoot protocol utilizing propan-2-ol or methanol for supercritical fluid or liquid chromatography, respectively, was proposed to detect and quantify 15 cathinones and phenethylamines in human urine. Both methods offered fast separation (<3 min) and short total analysis time. Precision was well <15% with a few exceptions in liquid chromatography. Limits of detection in urine ranged from 0.01 to 2.3 ng/mL, except for cathinone (5 ng/mL) in supercritical fluid chromatography. Nevertheless, this technique distinguished all analytes including four pairs of isomers, while liquid chromatography was unable to resolve fluoromethcathinone regioisomers. Concerning matrix effects and recoveries, supercritical fluid chromatography produced more uniform results for different compounds and at different concentration levels. This work demonstrates the performance and reliability of supercritical fluid chromatography and corroborates its applicability as an alternative tool for analysis of new psychoactive substances in biological matrixes. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Vibration analysis of partially cracked plate submerged in fluid
NASA Astrophysics Data System (ADS)
Soni, Shashank; Jain, N. K.; Joshi, P. V.
2018-01-01
The present work proposes an analytical model for vibration analysis of partially cracked rectangular plates coupled with fluid medium. The governing equation of motion for the isotropic plate based on the classical plate theory is modified to accommodate a part through continuous line crack according to simplified line spring model. The influence of surrounding fluid medium is incorporated in the governing equation in the form of inertia effects based on velocity potential function and Bernoulli's equations. Both partially and totally submerged plate configurations are considered. The governing equation also considers the in-plane stretching due to lateral deflection in the form of in-plane forces which introduces geometric non-linearity into the system. The fundamental frequencies are evaluated by expressing the lateral deflection in terms of modal functions. The assessment of the present results is carried out for intact submerged plate as to the best of the author's knowledge the literature lacks in analytical results for submerged cracked plates. New results for fundamental frequencies are presented as affected by crack length, fluid level, fluid density and immersed depth of plate. By employing the method of multiple scales, the frequency response and peak amplitude of the cracked structure is analyzed. The non-linear frequency response curves show the phenomenon of bending hardening or softening and the effect of fluid dynamic pressure on the response of the cracked plate.
Multi-fluid renewable geo-energy systems and methods
DOE Office of Scientific and Technical Information (OSTI.GOV)
Buscheck, Thomas A.
A geo-energy production method for extracting thermal energy from a reservoir formation. A production well extracts brine from the reservoir formation. A plurality of working fluid injection ("WFI") wells may be arranged proximate to the production well to at least partially circumscribe the production well. A plurality of brine production ("BP") wells may be arranged in a vicinity of the WFI wells to at least partially circumscribe the WFI wells. A working fluid is injected into the WFI wells to help drive a flow of the brine up through the production and BP wells, together with at least a portionmore » of the injected working fluid. Parasitic-load time-shifting and to storing of excess solar thermal energy may also be performed.« less
Exposure to fluoride in smelter workers in a primary aluminum industry in India.
Susheela, A K; Mondal, N K; Singh, A
2013-04-01
Fluoride is used increasingly in a variety of industries in India. Emission of fluoride dust and fumes from the smelters of primary aluminum producing industries is dissipated in the work environment and poses occupational health hazards. To study the prevalence of health complaints and its association with fluoride level in body fluids of smelter workers in a primary aluminum producing industry. In an aluminum industry, health status of 462 smelter workers, 60 supervisors working in the smelter unit, 62 non-smelter workers (control group 1) and 30 administration staff (control group 2) were assessed between 2007 and 2009. Their health complaints were recorded and categorized into 4 groups: 1) gastro-intestinal complaints; 2) non-skeletal manifestations; 3) skeletal symptoms; and (4) respiratory problems. Fluoride level in body fluids, nails, and drinking water was tested by an ion selective electrode; hemoglobin level was tested using HemoCue. The total complaints reported by study groups were significantly higher than the control groups. Smelter workers had a significantly (p<0.001) higher urinary and serum fluoride level than non-smelter workers; the nail fluoride content was also higher in smelter workers than non-smelter workers (p<0.001). The smelter workers with higher hemoglobin level had a significantly (p<0.001) lower urinary fluoride concentration and complained less frequently of health problems. Only 1.4% of the smelter workers were consuming water with high fluoride concentrations. A high percentage of participants was using substances with high fluoride contents. Industrial emission of fluoride is not the only important sources of fluoride exposure--consumption of substance with high levels of fluoride is another important route of entry of fluoride into the body. Measurement of hemoglobin provides a reliable indicator for monitoring the health status of employees at risk of fluorosis.
Effect of oxide films on hydrogen permeability of candidate Stirling heater head tube alloys
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schuon, S R; Misencik, J A
1981-01-01
High pressure hydrogen has been selected as the working fluid for the developmental automotive Stirling engine. Containment of the working fluid during operation of the engine at high temperatures and at high hydrogen gas pressures is essential for the acceptance of the Stirling engine as an alternative to the internal combustion engine. Most commercial alloys are extremely permeable to pure hydrogen at high temperatures. A program was undertaken at NASA Lewis Research Center (LeRC) to reduce hydrogen permeability in the Stirling engine heater head tubes by doping the hydrogen working fluid with CO or CO/sub 2/. Small additions of thesemore » gases were shown to form an oxide on the inside tube wall and thus reduce hydrogen permeability. A study of the effects of dopant concentration, alloy composition, and effects of surface oxides on hydrogen permeability in candidate heater head tube alloys is summarized. Results showed that hydrogen permeability was similar for iron-base alloys (N-155, A286, IN800, 19-9DL, and Nitronic 40), cobalt-base alloys (HS-188) and nickel-base alloys (IN718). In general, the permeability of the alloys decreased with increasing concentration of CO or CO/sub 2/ dopant, with increasing oxide thickness, and decreasing oxide porosity. At high levels of dopants, highly permeable liquid oxides formed on those alloys with greater than 50% Fe content. Furthermore, highly reactive minor alloying elements (Ti, Al, Nb, and La) had a strong influence on reducing hydrogen permeability.« less
PIV measurements in near-wake turbulent regions
NASA Astrophysics Data System (ADS)
Chen, Wei-Cheng; Chang, Keh-Chin
2018-05-01
Particle image velocimetry (PIV) is a non-intrusive optical diagnostic and must be made of the seedings (foreign particles) instead of the fluid itself. However, reliable PIV measurement of turbulence requires sufficient numbers of seeding falling in each interrogation window of image. A gray-level criterion is developed in this work to check the attainment of statistically stationary status of turbulent flow properties. It is suggested that the gray level of no less than 0.66 is used as the threshold for reliable PIV measurements in the present near-wake turbulent regions.
Effect of working fluids on thermal performance of closed loop pulsating heat pipe
NASA Astrophysics Data System (ADS)
Kolková, Zuzana; Malcho, Milan
2014-08-01
Improving the performance of electrical components needs higher heat removal from these systems. One of the solutions available is to use a sealed heat pipe with a throbbing filling, where development meets the current requirements for intensification of heat removal and elimination of moving parts cooling systems. Heat pipes operate using phase change working fluid, and it is evaporation and condensation. They have a meandering shape and are characterized by high intensity of heat transfer, high durability and reliability. Advantage of these tubes is that it is not necessary to create the internal capillary structure for transporting liquid and they need any pump to the working fluid circulation. They have a simple structure, low cost, high performance, and they can be used for various structural applications. The choice of working fluid volume and performance affects thermal performance. Distilled water, ethanol and acetone were used in the performance ranges 0-80%.
Heat exchanger life extension via in-situ reconditioning
Holcomb, David E.; Muralidharan, Govindarajan
2016-06-28
A method of in-situ reconditioning a heat exchanger includes the steps of: providing an in-service heat exchanger comprising a precipitate-strengthened alloy wherein at least one mechanical property of the heat exchanger is degraded by coarsening of the precipitate, the in-service heat exchanger containing a molten salt working heat exchange fluid; deactivating the heat exchanger from service in-situ; in a solution-annealing step, in-situ heating the heat exchanger and molten salt working heat exchange fluid contained therein to a temperature and for a time period sufficient to dissolve the coarsened precipitate; in a quenching step, flowing the molten salt working heat-exchange fluid through the heat exchanger in-situ to cool the alloy and retain a supersaturated solid solution while preventing formation of large precipitates; and in an aging step, further varying the temperature of the flowing molten salt working heat-exchange fluid to re-precipitate the dissolved precipitate.
NASA Astrophysics Data System (ADS)
Haavisto, Sanna; Cardona, Maria J.; Salmela, Juha; Powell, Robert L.; McCarthy, Michael J.; Kataja, Markku; Koponen, Antti I.
2017-11-01
A hybrid multi-scale velocimetry method utilizing Doppler optical coherence tomography in combination with either magnetic resonance imaging or ultrasound velocity profiling is used to investigate pipe flow of four rheologically different working fluids under varying flow regimes. These fluids include water, an aqueous xanthan gum solution, a softwood fiber suspension, and a microfibrillated cellulose suspension. The measurement setup enables not only the analysis of the rheological (bulk) behavior of a studied fluid but gives simultaneously information on their wall layer dynamics, both of which are needed for analyzing and solving practical fluid flow-related problems. Preliminary novel results on rheological and boundary layer flow properties of the working fluids are reported and the potential of the hybrid measurement setup is demonstrated.
The Contribution of Working Memory to Fluid Reasoning: Capacity, Control, or Both?
ERIC Educational Resources Information Center
Chuderski, Adam; Necka, Edward
2012-01-01
Fluid reasoning shares a large part of its variance with working memory capacity (WMC). The literature on working memory (WM) suggests that the capacity of the focus of attention responsible for simultaneous maintenance and integration of information within WM, as well as the effectiveness of executive control exerted over WM, determines…
Training Planning and Working Memory in Third Graders
ERIC Educational Resources Information Center
Goldin, Andrea Paula; Segretin, Maria Soledad; Hermida, Maria Julia; Paz, Luciano; Lipina, Sebastian Javier; Sigman, Mariano
2013-01-01
Working memory and planning are fundamental cognitive skills supporting fluid reasoning. We show that 2 games that train working memory and planning skills in school-aged children promote transfer to 2 different tasks: an attentional test and a fluid reasoning test. We also show long-term improvement of planning and memory capacities in…
On-Board Hydrogen Gas Production System For Stirling Engines
Johansson, Lennart N.
2004-06-29
A hydrogen production system for use in connection with Stirling engines. The production system generates hydrogen working gas and periodically supplies it to the Stirling engine as its working fluid in instances where loss of such working fluid occurs through usage through operation of the associated Stirling engine. The hydrogen gas may be generated by various techniques including electrolysis and stored by various means including the use of a metal hydride absorbing material. By controlling the temperature of the absorbing material, the stored hydrogen gas may be provided to the Stirling engine as needed. A hydrogen production system for use in connection with Stirling engines. The production system generates hydrogen working gas and periodically supplies it to the Stirling engine as its working fluid in instances where loss of such working fluid occurs through usage through operation of the associated Stirling engine. The hydrogen gas may be generated by various techniques including electrolysis and stored by various means including the use of a metal hydride absorbing material. By controlling the temperature of the absorbing material, the stored hydrogen gas may be provided to the Stirling engine as needed.
Working Memory Capacity and Fluid Intelligence: Maintenance and Disengagement.
Shipstead, Zach; Harrison, Tyler L; Engle, Randall W
2016-11-01
Working memory capacity and fluid intelligence have been demonstrated to be strongly correlated traits. Typically, high working memory capacity is believed to facilitate reasoning through accurate maintenance of relevant information. In this article, we present a proposal reframing this issue, such that tests of working memory capacity and fluid intelligence are seen as measuring complementary processes that facilitate complex cognition. Respectively, these are the ability to maintain access to critical information and the ability to disengage from or block outdated information. In the realm of problem solving, high working memory capacity allows a person to represent and maintain a problem accurately and stably, so that hypothesis testing can be conducted. However, as hypotheses are disproven or become untenable, disengaging from outdated problem solving attempts becomes important so that new hypotheses can be generated and tested. From this perspective, the strong correlation between working memory capacity and fluid intelligence is due not to one ability having a causal influence on the other but to separate attention-demanding mental functions that can be contrary to one another but are organized around top-down processing goals. © The Author(s) 2016.
Low-gravity fluid physics: A program overview
NASA Technical Reports Server (NTRS)
1990-01-01
An overview is presented of the microgravity fluid physics program at Lewis Research Center. One of the main reasons for conducting low gravity research in fluid physics is to study phenomena such as surface tension, interfacial contact angles, and diffusion independent of such gravitationally induced effects as buoyant convection. Fluid physics is at the heart of many space-based technologies including power systems, thermal control systems, and life support systems. Fundamental understanding of fluid physics is a key ingredient to successful space systems design. In addition to describing ground-based and space-based low-gravity facilities, selected experiments are presented which highlight Lewis work in fluid physics. These experiments can be categorized into five theme areas which summarize the work being conducted at Lewis for OSSA: (1) isothermal/iso-solutal capillary phenomena; (2) capillary phenomena with thermal/solutal gradients; (3) thermal-solutal convection; (4) first- and second-order phase transitions in a static fluid; and (5) multiphase flow.
30 CFR 250.1623 - Well-control fluids, equipment, and operations.
Code of Federal Regulations, 2011 CFR
2011-07-01
..., (2) A well-control fluid-volume measuring device for determining fluid volumes when filling the hole on trips, and (3) A recording mud-pit-level indicator to determine mud-pit-volume gains and losses... the change in fluid level decreases the hydrostatic pressure 75 psi or every five stands of drill pipe...
Cantón-Romero, Juan Carlos; Bañuelos-Ramírez, Jose Luis; Sifuentes-Franco, Sonia; Castellanos-González, José Alberto
2017-01-01
Diverse proinflammatory biomarkers and oxidative stress are strongly associated with advanced epithelial ovarian cancer (EOC). Objective. To determine the behavior of markers of oxidative stress and inflammation in plasma and ascites fluid in patients with platinum-sensitive, platinum-resistant, and platinum-refractory EOC. Methods. A prospective cohort study. The colorimetric method was used to determine levels of the markers 8-isoprostanes (8-IP), lipid peroxidation products (LPO), and total antioxidant capacity (TAC) in plasma and ascites fluid; and with ELISA, the levels of interleukin-6 (IL-6) and tumor necrosis factor alpha (TNF-α) were determined in patients with EOC. Results. In ascites fluid, a significant increase in 8-IP versus baseline plasma levels was found (p = 0.002). There was an important leakage of the TAC levels in ascites fluid versus baseline plasma levels (p < 0.001). The IL-6 was elevated in ascites fluid versus baseline plasma levels (p = 0.003), and there were diminished levels of TNF-α in ascites fluid versus baseline plasma levels (p = 0.001). Discussion. We hypothesize that the ascites fluid influences the behavior and dissemination of the tumor. Deregulation between oxidants, antioxidants, and the proinflammatory cytokines was found to vary among platinum-sensitive, platinum-resistant, and platinum-refractory patients. PMID:28848618
NASA Technical Reports Server (NTRS)
Peters, R. L.
1969-01-01
Improved cutting fluid completely controls the heat generated from machining operations, thus providing longer tool life. Fluid is especially useful in the working of plastics and replaces less efficient contaminating oils.
Settling of a sphere through a fluid-fluid interface: influence of the Reynolds number
NASA Astrophysics Data System (ADS)
Pierson, Jean-Lou; Magnaudet, Jacques
2015-11-01
When a particle sediments through a horizontal fluid-fluid interface (a situation frequently encountered in oceanography as well as in coating processes), it often tows a tail of the upper fluid into the lower one. This feature is observed in both inertia- and viscosity-dominated regimes. Nevertheless the tail evolution and the particle motion are found to highly depend on the ratio of the two effects, i.e. on the Reynolds number. In this work we study numerically the settling of a sphere through a horizontal fluid-fluid interface using an Immersed Boundary Method combined with a Volume of Fluid approach. To get some more insight into the underlying physical mechanisms, we combine this computational approach with a semi-analytical description based on the concept of Darwin ''drift'' which allows us to predict the interface evolution, hence the thickness of the film encapsulating the sphere, in the two limits of Stokes flow and potential flow. This work was funded by DGA whose financial support is greatly appreciated.
NASA Technical Reports Server (NTRS)
Spivey, Reggie; Flores, Ginger N.
2009-01-01
The Microgravity Science Glovebox (MSG) is a double rack facility aboard the International Space Station (ISS) designed for investigation handling. The MSG has been operating on the ISS since July 2002 and is currently located in the Columbus Laboratory Module. The unique design of the facility allows it to accommodate science and technology investigations in a workbench type environment. The facility has an enclosed working volume that is held at a negative pressure with respect to the crew living area. This allows the facility to provide two levels of containment for small parts, particulates, fluids, and gases. This containment approach protects the crew from possible hazardous operations that take place inside the MSG work volume. Research investigations operating inside the MSG are provided a large 255 liter enclosed work space, 1000 watts of dc power via a versatile supply interface (120, 28, +/- 12, and 5 Vdc), 1000 watts of cooling capability, video and data recording and real time downlink, ground commanding capabilities, access to ISS Vacuum Exhaust and Vacuum Resource Systems, and gaseous nitrogen supply. These capabilities make the MSG one of the most utilized facilities on ISS. In fact, the MSG has been used for over 5000 hours of scientific payload operations. MSG investigations involve research in cryogenic fluid management, fluid physics, spacecraft fire safety, materials science, combustion, plant growth, and life support technologies. MSG is an ideal platform for science investigations and research required to advance the technology readiness levels (TRLs) applicable to the Constellation Program. This paper will provide an overview of the MSG facility, a synopsis of the research that has already been accomplished in the MSG, an overview of future investigations currently planned for operation in the MSG, and potential applications of MSG investigations that can provide useful data to the Constellation Program. In addition, this paper will address the role of the MSG facility in the ISS National Lab.
Fluid flow analysis of E-glass fiber reinforced pipe joints in oil and gas industry
NASA Astrophysics Data System (ADS)
Bobba, Sujith; Leman, Z.; Zainuddin, E. S.; Sapuan, S. M.
2018-04-01
Glass Fiber reinforced composites have become increasingly important over the past few years and now they are the first choice materials for fabricating pipes with low weight in combination with high strength and stiffness. In Oil And Gas Industry, The Pipelines transporting heavy crude oil are subjected to variable pressure waves causing fluctuating stress levels in the pipes. Computational Fluid Dynamics (CFD) analysis was performed using solid works flow stimulation software to study the effects of these pressure waves on some specified joints in the pipes. Depending on the type of heavy crude oil being used, the flow behavior indicated a considerable degree of stress levels in certain connecting joints, causing the joints to become weak over a prolonged period of use. This research proposes a new perspective that is still required to be developed regarding the change of the pipe material, fiber winding angle in those specified joints and finally implementing cad wind technology to check the output result of the stress levels so that the life of the pipes can be optimized.
Santos, Sara Matos; Garcia-Nimo, Laura; Sá Santos, Sónia; Tavares, Isaura; Cocho, José A; Castanho, Miguel A R B
2013-01-01
In Alzheimer's disease (AD), besides the characteristic deterioration of memory, studies also point to a higher pain tolerance in spite of sensibility preservation. A change in the normal tau protein phosphorylation is also characteristic of AD, which contributes to the pathogenesis of the disease and is useful in early diagnosis. Kyotorphin (KTP) is an endogenous analgesic dipeptide (Tyr-Arg) for which there is evidence of eventual neuroprotective and neuromodulatory properties. The objective of this work was to study the possible correlation between KTP and phosphorylated tau protein (p-tau) levels in cerebro-spinal fluid (CSF) samples of AD patients. CSF samples were collected from 25 AD patients and 13 age-matched controls (N), where p-tau and KTP levels were measured. We found a statistically significant difference between p-tau/KTP values in AD and N groups with an inverse correlation between p-tau and KTP values in AD samples. These results suggest that in the future KTP may be a candidate biomarker for neurodegeneration and may be a lead compound to be used pharmacologically for neuroprotection.
Multiscale computational modeling of a radiantly driven solar thermal collector
NASA Astrophysics Data System (ADS)
Ponnuru, Koushik
The objectives of the master's thesis are to present, discuss and apply sequential multiscale modeling that combines analytical, numerical (finite element-based) and computational fluid dynamic (CFD) analysis to assist in the development of a radiantly driven macroscale solar thermal collector for energy harvesting. The solar thermal collector is a novel green energy system that converts solar energy to heat and utilizes dry air as a working heat transfer fluid (HTF). This energy system has important advantages over competitive technologies: it is self-contained (no energy sources are needed), there are no moving parts, no oil or supplementary fluids are needed and it is environmentally friendly since it is powered by solar radiation. This work focuses on the development of multi-physics and multiscale models for predicting the performance of the solar thermal collector. Model construction and validation is organized around three distinct and complementary levels. The first level involves an analytical analysis of the thermal transpiration phenomenon and models for predicting the associated mass flow pumping that occurs in an aerogel membrane in the presence of a large thermal gradient. Within the aerogel, a combination of convection, conduction and radiation occurs simultaneously in a domain where the pore size is comparable to the mean free path of the gas molecules. CFD modeling of thermal transpiration is not possible because all the available commercial CFD codes solve the Navier Stokes equations only for continuum flow, which is based on the assumption that the net molecular mass diffusion is zero. However, thermal transpiration occurs in a flow regime where a non-zero net molecular mass diffusion exists. Thus these effects are modeled by using Sharipov's [2] analytical expression for gas flow characterized by high Knudsen number. The second level uses a detailed CFD model solving Navier Stokes equations for momentum, heat and mass transfer in the various components of the device. We have used state-of-the-art computational fluid dynamics (CFD) software, Flow3D (www.flow3d.com) to model the effects of multiple coupled physical processes including buoyancy driven flow from local temperature differences within the plenums, fluid-solid momentum and heat transfer, and coupled radiation exchange between the aerogel, top glazing and environment. In addition, the CFD models include both convection and radiation exchange between the top glazing and the environment. Transient and steady-state thermal models have been constructed using COMSOL Multiphysics. The third level consists of a lumped-element system model, which enables rapid parametric analysis and helps to develop an understanding of the system behavior; the mathematical models developed and multiple CFD simulations studies focus on simultaneous solution of heat, momentum, mass and gas volume fraction balances and succeed in accurate state variable distributions confirmed by experimental measurements.
Early- or mid-trimester amniocentesis biomarkers for predicting preterm delivery: a meta-analysis.
Liu, Yinglin; Liu, Yukun; Zhang, Rui; Zhu, Liqiong; Feng, Ziya
2017-02-01
To determine the value of early- or mid-trimester amniotic fluid levels of interleukin-6 (IL-6), matrix metalloproteinase-8 (MMP-8), and glucose for predicting preterm delivery. Randomized controlled trials and two-arm prospective, retrospective, cohorts, and case-controlled studies in which patients received early- or mid-trimester amniocentesis for karyotyping, and biomarker testing of the amniotic fluid was performed and delivery data were available were included in the analysis. Outcome measures were the associations of amniotic fluid IL-6, MMP-8, and glucose levels with preterm delivery. Differences in means with 95% confidence intervals (CIs) were calculated. Of 288 articles identified, 14 were included in the meta-analysis with a total of 675 patients who had preterm birth and 2518 patients who had term births. The preterm-delivery group had significantly higher amniotic fluid IL-6 and MMP-8 levels, and a significantly lower glucose level than the term delivery group (IL-6: difference in means = 0.32, 95% CI: 0.22-0.43, p < 0.001; MMP-8: difference in means = 4.47, 95% CI: 0.83-8.11), p = 0.016; glucose: difference in means = -5.22, 95% CI: -8.19 to -2.26, p = 0.001) Conclusion: Early- or mid-trimester amniotic fluid IL-6, MMP-8, and glucose levels are useful for predicting the risk of preterm delivery. KEY MESSAGES Median amniotic fluid ferritin and IL-6 levels, and mean amniotic fluid ALP levels were higher in the preterm group. The preterm-delivery group had significantly higher amniotic fluid IL-6 and MMP-8 levels, and a significantly lower glucose level than the term-delivery group.
Fluid absorption solar energy receiver
NASA Technical Reports Server (NTRS)
Bair, Edward J.
1993-01-01
A conventional solar dynamic system transmits solar energy to the flowing fluid of a thermodynamic cycle through structures which contain the gas and thermal energy storage material. Such a heat transfer mechanism dictates that the structure operate at a higher temperature than the fluid. This investigation reports on a fluid absorption receiver where only a part of the solar energy is transmitted to the structure. The other part is absorbed directly by the fluid. By proportioning these two heat transfer paths the energy to the structure can preheat the fluid, while the energy absorbed directly by the fluid raises the fluid to its final working temperature. The surface temperatures need not exceed the output temperature of the fluid. This makes the output temperature of the gas the maximum temperature in the system. The gas can have local maximum temperatures higher than the output working temperature. However local high temperatures are quickly equilibrated, and since the gas does not emit radiation, local high temperatures do not result in a radiative heat loss. Thermal radiation, thermal conductivity, and heat exchange with the gas all help equilibrate the surface temperature.
SNR-optimized phase-sensitive dual-acquisition turbo spin echo imaging: a fast alternative to FLAIR.
Lee, Hyunyeol; Park, Jaeseok
2013-07-01
Phase-sensitive dual-acquisition single-slab three-dimensional turbo spin echo imaging was recently introduced, producing high-resolution isotropic cerebrospinal fluid attenuated brain images without long inversion recovery preparation. Despite the advantages, the weighted-averaging-based technique suffers from noise amplification resulting from different levels of cerebrospinal fluid signal modulations over the two acquisitions. The purpose of this work is to develop a signal-to-noise ratio-optimized version of the phase-sensitive dual-acquisition single-slab three-dimensional turbo spin echo. Variable refocusing flip angles in the first acquisition are calculated using a three-step prescribed signal evolution while those in the second acquisition are calculated using a two-step pseudo-steady state signal transition with a high flip-angle pseudo-steady state at a later portion of the echo train, balancing the levels of cerebrospinal fluid signals in both the acquisitions. Low spatial frequency signals are sampled during the high flip-angle pseudo-steady state to further suppress noise. Numerical simulations of the Bloch equations were performed to evaluate signal evolutions of brain tissues along the echo train and optimize imaging parameters. In vivo studies demonstrate that compared with conventional phase-sensitive dual-acquisition single-slab three-dimensional turbo spin echo, the proposed optimization yields 74% increase in apparent signal-to-noise ratio for gray matter and 32% decrease in imaging time. The proposed method can be a potential alternative to conventional fluid-attenuated imaging. Copyright © 2012 Wiley Periodicals, Inc.
Cycle simulation of the low-temperature triple-effect absorption chiller with vapor compression unit
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, J.S.; Lee, H.
1999-07-01
The construction of a triple-effect absorption chiller machine using the lithium bromide-water solution as a working fluid is strongly limited by corrosion problems caused by the high generator temperature. In this work, three new cycles having the additional vapor compression units were suggested in order to lower the generator temperature of a triple-effect absorption chiller. Each new cycle has one compressor located at the different position which was used to elevate the pressure of the refrigerant vapor. Computer simulations were carried out in order to examine both the basic triple-effect cycle and three new cycles. All types of triple-effect absorptionmore » chiller cycles were found to be able to lower the temperature of high-temperature generator to the more favorable operation range. The COPs of three cycles calculated by considering the additional compressor works showed a small level of decrease or increase compared with that of the basic triple-effect cycle. Consequently, a low-temperature triple-effect absorption chiller can be possibly constructed by adapting one of three new cycles. A great advantage of these new cycles over the basic one is that the conventionally used lithium bromide-water solution can be successfully used as a working fluid without the danger of corrosion.« less
Quantum Otto engine using a single ion and a single thermal bath
NASA Astrophysics Data System (ADS)
Biswas, Asoka; Chand, Suman
2016-05-01
Quantum heat engines employ a quantum system as the working fluid, that gives rise to large work efficiency, beyond the limit for classical heat engines. Existing proposals for implementing quantum heat engines require that the system interacts with the hot bath and the cold bath (both modelled as a classical system) in an alternative fashion and therefore assumes ability to switch off the interaction with the bath during a certain stage of the heat-cycle. However, it is not possible to decouple a quantum system from its always-on interaction with the bath without use of complex pulse sequences. It is also hard to identify two different baths at two different temperatures in quantum domain, that sequentially interact with the system. Here, we show how to implement a quantum Otto engine without requiring to decouple the bath in a sequential manner. This is done by considering a single thermal bath, coupled to a single trapped ion. The electronic degree of freedom of the ion is chosen as a two-level working fluid while the vibrational degree of freedom plays the role of the cold bath. Measuring the electronic state mimics the release of heat into the cold bath. Thus, our model is fully quantum and exhibits very large work efficiency, asymptotically close to unity.
Intermediate Temperature Fluids Life Tests - Experiments
NASA Technical Reports Server (NTRS)
Anderson, William G.; Bonner, Richard W.; Dussinger, Peter M.; Hartenstine, John R.; Sarraf, David B.; Locci, Ivan E.
2007-01-01
There are a number of different applications that could use heat pipes or loop heat pipes (LHPs) in the intermediate temperature range of 450 to 725 K (170 to 450 C), including space nuclear power system radiators, fuel cells, and high temperature electronics cooling. Historically, water has been used in heat pipes at temperatures up to about 425 K (150 C). Recent life tests, updated below, demonstrate that titanium/water and Monel/water heat pipes can be used at temperatures up to 550 K (277 C), due to water's favorable transport properties. At temperatures above roughly 570 K (300 C), water is no longer a suitable fluid, due to high vapor pressure and low surface tension as the critical point is approached. At higher temperatures, another working fluid/envelope combination is required, either an organic or halide working fluid. An electromotive force method was used to predict the compatibility of halide working fluids with envelope materials. This procedure was used to reject aluminum and aluminum alloys as envelope materials, due to their high decomposition potential. Titanium and three corrosion resistant superalloys were chosen as envelope materials. Life tests were conducted with these envelopes and six different working fluids: AlBr3, GaCl3, SnCl4, TiCl4, TiBr4, and eutectic diphenyl/diphenyl oxide (Therminol VP-1/Dowtherm A). All of the life tests except for the GaCl3 are ongoing; the GaCl3 was incompatible. As the temperature approaches 725 K (450 C), cesium is a potential heat pipe working fluid. Life tests results are also presented for cesium/Monel 400 and cesium/70-30 copper/nickel heat pipes operating near 750 K (477 C). These materials are not suitable for long term operation, due to copper transport from the condenser to the evaporator.
NASA Astrophysics Data System (ADS)
Susmitha, M.; Sharan, P.; Jyothi, P. N.
2016-09-01
Friction between work piece-cutting tool-chip generates heat in the machining zone. The heat generated reduces the tool life, increases surface roughness and decreases the dimensional sensitiveness of work material. This can be overcome by using cutting fluids during machining. They are used to provide lubrication and cooling effects between cutting tool and work piece and cutting tool and chip during machining operation. As a result, important benefits would be achieved such longer tool life, easy chip flow and higher machining quality in the machining processes. Non-edible vegetable oils have received considerable research attention in the last decades owing to their remarkable improved tribological characteristics and due to increasing attention to environmental issues, have driven the lubricant industry toward eco friendly products from renewable sources. In the present work, different non-edible vegetable oils are used as cutting fluid during drilling of Mild steel work piece. Non-edible vegetable oils, used are Karanja oil (Honge), Neem oil and blend of these two oils. The effect of these cutting fluids on chip formation, surface roughness and cutting force are investigated and the results obtained are compared with results obtained with petroleum based cutting fluids and dry conditions.
Hyun, Jinshil; Sliwinski, Martin J; Almeida, David M; Smyth, Joshua M; Scott, Stacey B
2018-05-01
Given that the association between work stress and negative affect can exacerbate negative health and workplace outcomes, it is important to identify the protective and risk factors that moderate this association. Socioemotional aging and cognitive abilities might influence how people utilize emotion regulation skills and engage in practical problem solving to manage their work stress. The aim of this study is to examine whether age and cognitive abilities independently and interactively moderate the association between work-related stress and negative affect. A diverse working adult sample (N = 139, age 25-65, 69% of females) completed a cross-sectional survey that assessed chronic work stress, negative affect, and fluid and crystallized cognitive abilities. Results from regression analyses suggested that both fluid and crystallized cognitive abilities, but not age, moderated the association between work stress and negative affect. Further, we found that crystallized cognition had a stronger attenuating effect on the work stress-negative affect association for older compared to younger workers. The moderating effect of fluid cognition was invariant across age. Our findings demonstrate that cognitive abilities are an important personal resource that might protect individuals against the negative impacts of work stress and negative affect. Although the role that fluid cognition plays in work stress-negative affect association is comparably important for both younger and older workers, crystallized cognition might play a more valuable role for older than younger workers.
Low-G fluid behavior technology summaries
NASA Technical Reports Server (NTRS)
Stark, J. A.; Bradshaw, R. D.; Blatt, M. H.
1974-01-01
This report presents a summarization and categorization of the pertinent literature associated with low-g fluid behavior technology. Initially a literature search was conducted to obtain pertinent documents for review. Reports determined to be of primary significance are summarized in detail. Each summary, where applicable, consists of; (1) report identification, (2) objective(s) of the work, (3) description of pertinent work performed, (4) major results, and (5) comments of the reviewer (GD/C). Pertinent figures are presented on a single facing page separate from the text. Specific areas covered are; interface configuration, interface stability, natural frequency and damping, liquid reorientation, bubbles and droplets, fluid inflow, fluid outflow, convection, boiling and condensation heat transfer, venting effects, and fluid properties. Reports which were reviewed and not summarized, along with reasons for not summarizing, are also listed. Cryogenic thermal control and fluid management systems technology are presented.
Thermal Control Working Group report
NASA Technical Reports Server (NTRS)
Haslett, Robert; Mahefkey, E. Thomas
1986-01-01
The Thermal Control Working Group limited its evaluation to issues associated with Earth orbiting and planetary spacecraft with power levels up to 50 kW. It was concluded that the space station technology is a necessary precursor but does not meet S/C 2000 needs (life, high heat flux, long term cryogenics, and survivability). Additional basic and applied research are required (fluid/materials compatibility and two phase system modeling). Scaling, the key issue, must define accelerated life test criteria. The two phase systems require 0g to 1 g correlation. Additional ground test beds are required and combined space environment tests of materials.
Superconducting-circuit quantum heat engine with frequency resolved thermal baths
NASA Astrophysics Data System (ADS)
Hofer, Patrick P.; Souquet, Jean-René; Clerk, Aashish A.
The study of quantum heat engines promises to unravel deep, fundamental concepts in quantum thermodynamics. With this in mind, we propose a novel, realistic device that efficiently converts heat into work while maintaining reasonably large output powers. The key concept in our proposal is a highly peaked spectral density in both the thermal baths as well as the working fluid. This allows for a complete separation of the heat current from the working fluid. In our setup, Cooper pairs tunnelling across a Josephson junction serve as the the working fluid, while two resonant cavities coupled to the junction act as frequency-resolved thermal baths. The device is operated such that a heat flux carried entirely by the photons induces an electrical current against a voltage bias, providing work.
Reactive oxygen species level in follicular fluid--embryo quality marker in IVF?
Das, S; Chattopadhyay, R; Ghosh, S; Ghosh, S; Goswami, S K; Chakravarty, B N; Chaudhury, K
2006-09-01
The impact of oxidative stress in female reproduction is not clear. Contradictory reports on the effect of various oxidative stress markers on follicular fluid, oocytes and embryo quality and fertilization potential exist. The objectives of this study were to examine reactive oxygen species (ROS) levels in follicular fluid of women undergoing IVF and to relate these levels to embryo formation and quality. A total of 208 follicular fluid samples were obtained from 78 women undergoing controlled ovarian stimulation and analysed for ROS and lipid peroxidation (LPO). These samples were divided into groups I and II which represented follicular fluid containing grade III and grade II oocytes, respectively. These groups were further subdivided into groups IA, IB, IIA and IIB according to embryo quality. Subgroups IA and IIA consisted of follicular fluid samples corresponding to grade I/II embryo formation. Subgroups IB and IIB represented fertilization failure/pro-nucleolus (PN) arrest/grade III embryos. No significant correlation was observed in ROS levels on comparing groups I and II (P > 0.05). However, ROS levels were observed to be significantly different on comparing groups IA and IB (P < or = 0.01) and groups IIA and IIB (P < or = 0.05). LPO levels further supported our results. ROS levels in follicular fluid appear to play a significant role in embryo formation and quality.
Lawlor-Savage, Linette; Goghari, Vina M.
2017-01-01
Training of working memory as a method of increasing working memory capacity and fluid intelligence has received much attention in recent years. This burgeoning field remains highly controversial with empirically-backed disagreements at all levels of evidence, including individual studies, systematic reviews, and even meta-analyses. The current study investigated the effect of a randomized six week online working memory intervention on untrained cognitive abilities in a community-recruited sample of healthy young adults, in relation to both a processing speed training active control condition, as well as a no-contact control condition. Results of traditional null hypothesis significance testing, as well as Bayesian factor analyses, revealed support for the null hypothesis across all cognitive tests administered before and after training. Importantly, all three groups were similar at pre-training for a variety of individual variables purported to moderate transfer of training to fluid intelligence, including personality traits, motivation to train, and expectations of cognitive improvement from training. Because these results are consistent with experimental trials of equal or greater methodological rigor, we suggest that future research re-focus on: 1) other promising interventions known to increase memory performance in healthy young adults, and; 2) examining sub-populations or alternative populations in which working memory training may be efficacious. PMID:28558000
Parametric study of fluid flow manipulation with piezoelectric macrofiber composite flaps
NASA Astrophysics Data System (ADS)
Sadeghi, O.; Tarazaga, P.; Stremler, M.; Shahab, S.
2017-04-01
Active Fluid Flow Control (AFFC) has received great research attention due to its significant potential in engineering applications. It is known that drag reduction, turbulence management, flow separation delay and noise suppression through active control can result in significantly increased efficiency of future commercial transport vehicles and gas turbine engines. In microfluidics systems, AFFC has mainly been used to manipulate fluid passing through the microfluidic device. We put forward a conceptual approach for fluid flow manipulation by coupling multiple vibrating structures through flow interactions in an otherwise quiescent fluid. Previous investigations of piezoelectric flaps interacting with a fluid have focused on a single flap. In this work, arrays of closely-spaced, free-standing piezoelectric flaps are attached perpendicular to the bottom surface of a tank. The coupling of vibrating flaps due to their interacting with the surrounding fluid is investigated in air (for calibration) and under water. Actuated flaps are driven with a harmonic input voltage, which results in bending vibration of the flaps that can work with or against the flow-induced bending. The size and spatial distribution of the attached flaps, and the phase and frequency of the input actuation voltage are the key parameters to be investigated in this work. Our analysis will characterize the electrohydroelastic dynamics of active, interacting flaps and the fluid motion induced by the system.
Expertise and age-related changes in components of intelligence.
Masunaga, H; Horn, J
2001-06-01
In a sample of 263 male GO players at 48 levels of expertise and ranging from 18 to 78 years of age, it was found that factors of expertise deductive reasoning (EDR) and expertise working memory (EWM) were independent of factors of fluid reasoning (Gf) and short-term working memory (STWM) that, along with cognitive speed (Gs), have been found to characterize decline of intelligence in adulthood. The main effects of analyses of cross-sectional age differences indicated age-related decline in EDR and EWM as well as in Gf, STWM, and Gs. However, interaction and partialing analyses indicated that decline in EDR and EWM decreased to no decline with increase in level of expertise. The results thus suggest that with increase in factors known to raise the level of expertise--particularly, intensive, well-designed practice--there may be no age-related decline in the intelligence that is measured in the abilities of expertise.
Highly resolved fluid flows: "liquid plasmas" at the kinetic level.
Morfill, Gregor E; Rubin-Zuzic, Milenko; Rothermel, Hermann; Ivlev, Alexei V; Klumov, Boris A; Thomas, Hubertus M; Konopka, Uwe; Steinberg, Victor
2004-04-30
Fluid flow around an obstacle was observed at the kinetic (individual particle) level using "complex (dusty) plasmas" in their liquid state. These "liquid plasmas" have bulk properties similar to water (e.g., viscosity), and a comparison in terms of similarity parameters suggests that they can provide a unique tool to model classical fluids. This allows us to study "nanofluidics" at the most elementary-the particle-level, including the transition from fluid behavior to purely kinetic transport. In this (first) experimental investigation we describe the kinetic flow topology, discuss our observations in terms of fluid theories, and follow this up with numerical simulations.
Fotiou, Maria; Michaelidou, Alexandra-Maria; Masoura, Sophia; Menexes, Georgios; Koulourida, Vasiliki; Biliaderis, Costas G; Tarlatzis, Basil C; Athanasiadis, Apostolos P
2016-12-01
The precise etiopathogenesis of preeclampsia (PE) still remains enigmatic. In recent published work, there is a scientific trend aiming to unveil early biomarkers of PE based on amniotic fluid compositional changes before the development of clinical symptoms. We describe a case of an apparently clinically healthy woman, whose amniotic fluid, retrieved after amniocentesis at 22 2/7 gestational week, had elevated uric acid and potassium concentration, as well as cysteine to methionine ratio. At the time of amniocentesis, conventional clinical signs of PE were absent. The woman developed severe PE and intrauterine growth restriction, at the 28 0/7 week of gestation. Although the limitation of such studies lies in the fact that amniocentesis is an invasive procedure, and thus employed only under specific indications, our scientific observations might be useful for future research towards unraveling the causes of PE. Copyright © 2016. Published by Elsevier B.V.
Cryogenic Fluid Storage Technology Development: Recent and Planned Efforts at NASA
NASA Technical Reports Server (NTRS)
Moran, Matthew E.
2009-01-01
Recent technology development work conducted at NASA in the area of Cryogenic Fluid Management (CFM) storage is highlighted, including summary results, key impacts, and ongoing efforts. Thermodynamic vent system (TVS) ground test results are shown for hydrogen, methane, and oxygen. Joule-Thomson (J-T) device tests related to clogging in hydrogen are summarized, along with the absence of clogging in oxygen and methane tests. Confirmation of analytical relations and bonding techniques for broad area cooling (BAC) concepts based on tube-to-tank tests are presented. Results of two-phase lumped-parameter computational fluid dynamic (CFD) models are highlighted, including validation of the model with hydrogen self pressurization test data. These models were used to simulate Altair representative methane and oxygen tanks subjected to 210 days of lunar surface storage. Engineering analysis tools being developed to support system level trades and vehicle propulsion system designs are also cited. Finally, prioritized technology development risks identified for Constellation cryogenic propulsion systems are presented, and future efforts to address those risks are discussed.
Ren, Xingfei; Wu, Chunlei; Yu, Qinnan; Zhu, Feng; Liu, Pei; Zhang, Huiqing
2016-01-01
To investigate the correlation of the levels of interleukin-8 (IL-8) and IL-6 in the prostatic fluid with serum levels of serum prostate-specific antigen (PSA) in patients with benign prostatic hyperplasia (BPH) complicated by prostatitis. A series of 211 patients undergoing surgery of BPH were divided into BPH group (n=75) and BPH with prostatitis group (n=136) according to the white blood cell count in the prostatic fluid. The clinical and laboratory findings were compared between the two groups, and stepwise regression analysis was used to assess the association of IL-8 and IL-6 with serum PSA level. No significant differences were found in age, BMI, blood pressure, blood glucose, blood lipids, IPSS score, PSA-Ratio, or prostate volume between the two groups (P<0.05). The patients with prostatitis had significantly increased serum PSA and prostate fluid IL-8 and IL-6 levels compared with those without prostatitis (P<0.001). Multiple linear regression analysis showed that IL-8 and IL-6 levels and white blood cell count in the prostatic fluid were all positively correlated with serum PSA level. Prostatitis is an important risk factor for elevated serum PSA level in patients with BPH, and both IL-8 and IL-6 levels in the prostatic fluid are correlated with serum PSA level.
NASA Technical Reports Server (NTRS)
Ross, Graham O.
1994-01-01
This paper describes the status and plans for the work being performed under NASA NRA contract NASW-4803 so that members of the Microgravity Fluid Dynamics Discipline Working Group are aware of this program. The contract is a cross-disciplinary research program and is administered under the Low Temperature Microgravity Research Program at the Jet Propulsion Laboratory. The purpose of the project is to perform low-gravity verification experiments on the slosh behavior of He II to use in the development of a CFD model that incorporates the two-fluid physics of He II. The two-fluid code predicts a different fluid motion response in low-gravity environment from that predicted by a single-fluid model, while the 1g response is identical for the both types of model.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Love, Lonnie J; Richardson, Bradley S; Lind, Randall F
This work explores the integration of miniaturized fluid power and additive manufacturing. Oak Ridge National Laboratory (ORNL) has been developing an approach to miniaturized fluidic actuation and control that enables high dexterity, low cost and a pathway towards energy efficiency. Previous work focused on mesoscale digital control valves (high pressure, low flow) and the integration of actuation and fluid passages directly with the structure. The primary application being fluid powered robotics. The fundamental challenge was part complexity. Additive manufacturing technologies (E-Beam, Laser and Ultrasonic deposition) enable freeform manufacturing using conventional metal alloys with excellent mechanical properties. The combination of thesemore » two technologies (miniaturized fluid power and additive manufacturing) can enable a paradigm shift in fluid power, increasing efficiency while simultaneously reducing weight, size, complexity and cost.« less
Long-Period Fiber Grating Sensors for the Measurement of Liquid Level and Fluid-Flow Velocity
Wang, Jian-Neng; Luo, Ching-Ying
2012-01-01
This paper presents the development and assessment of two types of Long Period Fiber Grating (LPFG)-based sensors including a mobile liquid level sensor and a reflective sensor for the measurement of liquid level and fluid-flow velocity. Shewhart control charts were used to assess the liquid level sensing capacity and reliability of the mobile CO2-laser engraved LPFG sensor. There were ten groups of different liquid level experiment and each group underwent ten repeated wavelength shift measurements. The results showed that all measurands were within the control limits; thus, this mobile sensor was reliable and exhibited at least 100-cm liquid level measurement capacity. In addition, a reflective sensor consisting of five LPFGs in series with a reflective end has been developed to evaluate the liquid level and fluid-flow velocity. These five LPFGs were fabricated by the electrical arc discharge method and the reflective end was coated with silver by Tollen's test. After each liquid level experiment was performed five times, the average values of the resonance wavelength shifts for LPFG Nos. 1–5 were in the range of 1.35–9.14 nm. The experimental findings showed that the reflective sensor could be used to automatically monitor five fixed liquid levels. This reflective sensor also exhibited at least 100-cm liquid level measurement capacity. The mechanism of the fluid-flow velocity sensor was based on analyzing the relationship among the optical power, time, and the LPFG's length. There were two types of fluid-flow velocity measurements: inflow and drainage processes. The differences between the LPFG-based fluid-flow velocities and the measured average fluid-flow velocities were found in the range of 8.7–12.6%. For the first time to our knowledge, we have demonstrated the feasibility of liquid level and fluid-flow velocity sensing with a reflective LPFG-based sensor without modifying LPFGs or coating chemical compounds. PMID:22666046
Long-period fiber grating sensors for the measurement of liquid level and fluid-flow velocity.
Wang, Jian-Neng; Luo, Ching-Ying
2012-01-01
This paper presents the development and assessment of two types of Long Period Fiber Grating (LPFG)-based sensors including a mobile liquid level sensor and a reflective sensor for the measurement of liquid level and fluid-flow velocity. Shewhart control charts were used to assess the liquid level sensing capacity and reliability of the mobile CO(2)-laser engraved LPFG sensor. There were ten groups of different liquid level experiment and each group underwent ten repeated wavelength shift measurements. The results showed that all measurands were within the control limits; thus, this mobile sensor was reliable and exhibited at least 100-cm liquid level measurement capacity. In addition, a reflective sensor consisting of five LPFGs in series with a reflective end has been developed to evaluate the liquid level and fluid-flow velocity. These five LPFGs were fabricated by the electrical arc discharge method and the reflective end was coated with silver by Tollen's test. After each liquid level experiment was performed five times, the average values of the resonance wavelength shifts for LPFG Nos. 1-5 were in the range of 1.35-9.14 nm. The experimental findings showed that the reflective sensor could be used to automatically monitor five fixed liquid levels. This reflective sensor also exhibited at least 100-cm liquid level measurement capacity. The mechanism of the fluid-flow velocity sensor was based on analyzing the relationship among the optical power, time, and the LPFG's length. There were two types of fluid-flow velocity measurements: inflow and drainage processes. The differences between the LPFG-based fluid-flow velocities and the measured average fluid-flow velocities were found in the range of 8.7-12.6%. For the first time to our knowledge, we have demonstrated the feasibility of liquid level and fluid-flow velocity sensing with a reflective LPFG-based sensor without modifying LPFGs or coating chemical compounds.
Ahrari, Shahnaz; Moshki, Mahdi; Bahrami, Mahnaz
2014-01-01
Introduction: Patient's noncompliance dietary and fluids intake can lead to a build-up of toxic fluids and metabolic end-products in the blood stream which may result in an increased morbidity and premature death. The aim of the study is investigate relationship between the social support and adherence to dietary and fluid restrictions in hemodialysis patients. Methods: In this correlational study upon 237 hemodialysis patients, the data was collected with the dialysis diet and fluids non-adherences hemodialysis questionnaire (DDFQ), and the multidimensional scale of perceived Social Support (MSP). Interdialytic weight gain, predialytic serum potassium levels, and predialytic serum phosphate levels was considered as biochemical indicators of dietary and fluid adherence. Data were analyzed by SPSS Ver.11.5. Results: About 41.1% of patients reported non-adherence to diet and 45.2% of them reported non-adherence to fluid. Frequency of non-adherence to fluid was more common in patients. The highest level of perceived support was the family support 11.19 (1.34). There was a significant relationship between social support and adherence to dietary and fluid restrictions. Noncompliances to dietary and fluid restrictions were related to laboratory results. Conclusion: This way those patients who more supported had more adherences of diet and fluid restrictions and had lower level of phosphorus and potassium in laboratory results. Nurses have the main role to identify different methods providing social support for patients, also to encourage the families to support their hemodialysis patients. PMID:25276744
Comparison of reproducibility of natural head position using two methods.
Khan, Abdul Rahim; Rajesh, R N G; Dinesh, M R; Sanjay, N; Girish, K S; Venkataraghavan, Karthik
2012-01-01
Lateral cephalometric radiographs have become virtually indispensable to orthodontists in the treatment of patients. They are important in orthodontic growth analysis, diagnosis, treatment planning, monitoring of therapy and evaluation of final treatment outcome. The purpose of this study was to evaluate and compare the maximum reproducibility with minimum variation of natural head position using two methods, i.e. the mirror method and the fluid level device method. The study included two sets of 40 lateral cephalograms taken using two methods of obtaining natural head position: (1) The mirror method and (2) fluid level device method, with a time interval of 2 months. Inclusion criteria • Subjects were randomly selected aged between 18 to 26 years Exclusion criteria • History of orthodontic treatment • Any history of respiratory tract problem or chronic mouth breathing • Any congenital deformity • History of traumatically-induced deformity • History of myofacial pain syndrome • Any previous history of head and neck surgery. The result showed that both the methods for obtaining natural head position-the mirror method and fluid level device method were comparable, but maximum reproducibility was more with the fluid level device as shown by the Dahlberg's coefficient and Bland-Altman plot. The minimum variance was seen with the fluid level device method as shown by Precision and Pearson correlation. The mirror method and the fluid level device method used for obtaining natural head position were comparable without any significance, and the fluid level device method was more reproducible and showed less variance when compared to mirror method for obtaining natural head position. Fluid level device method was more reproducible and shows less variance when compared to mirror method for obtaining natural head position.
Tambara, Keiichi; Fujita, Masatoshi; Miyamoto, Shoichi; Doi, Kazuhiko; Nishimura, Kazunobu; Komeda, Masashi
2004-02-01
Heart-type cytoplasmic fatty acid-binding protein (H-FABP) has been reported as a sensitive and specific marker for the early diagnosis of acute myocardial infarction. Our hypothesis was that serum or pericardial fluid levels of H-FABP can reflect not only myocardial infarction but also myocardial ischemia. A total of 34 patients with unstable angina, who had anginal symptoms and/or ST-changes in ECG monitoring within 24 h before operation, were classified into group A (n=17), and those without these symptoms and changes into group B (n=17). Blood and pericardial fluid samples were obtained immediately after median sternotomy, and serum and pericardial fluid levels of creatine kinase-MB, cardiac troponin-T, and H-FABP were measured. Serum H-FABP levels were slightly elevated compared with their normal values in both groups. While they showed no difference between groups A and B (group A vs. B: 8.5+/-1.0 vs. 7.1+/-0.7 ng/ml, P=0.25), pericardial fluid levels of H-FABP were significantly higher in group A than in group B (16.3+/-2.0 vs. 9.6+/-1.0 ng/ml, P=0.0046). H-FABP showed a weak correlation between its serum levels and pericardial fluid levels (r=0.40). Pericardial fluid levels of H-FABP reflect myocardial ischemia occurring within 24 h of their measurements. H-FABP may be secreted into the interstitial space by increased permeability of the myocardial cell membrane associated with severe myocardial ischemia. Thus, pericardial fluid reflects pathophysiological conditions of cardiomyocytes more sensitively than circulating blood.
NASA Astrophysics Data System (ADS)
Yilbas, B. S.; Shuja, S. Z.
2017-01-01
Thermal performance of a solar volumetric receiver incorporating the different cell geometric configurations is investigated. Triangular, hexagonal, and rectangular absorbing cells are incorporated in the analysis. The fluid volume fraction, which is the ratio of the volume of the working fluid over the total volume of solar volumetric receiver, is introduced to assess the effect of cell size on the heat transfer rates in the receiver. In this case, reducing the fluid volume fraction corresponds to increasing cell size in the receiver. SiC is considered as the cell material, and air is used as the working fluid in the receiver. The Lambert's Beer law is incorporated to account for the solar absorption in the receiver. A finite element method is used to solve the governing equation of flow and heat transfer. It is found that the fluid volume fraction has significant effect on the flow field in the solar volumetric receiver, which also modifies thermal field in the working fluid. The triangular absorbing cell gives rise to improved effectiveness of the receiver and then follows the hexagonal and rectangular cells. The second law efficiency of the receiver remains high when hexagonal cells are used. This occurs for the fluid volume fraction ratio of 0.5.
Blood glucose level reconstruction as a function of transcapillary glucose transport.
Koutny, Tomas
2014-10-01
A diabetic patient occasionally undergoes a detailed monitoring of their glucose levels. Over the course of a few days, a monitoring system provides a detailed track of their interstitial fluid glucose levels measured in their subcutaneous tissue. A discrepancy in the blood and interstitial fluid glucose levels is unimportant because the blood glucose levels are not measured continuously. Approximately five blood glucose level samples are taken per day, and the interstitial fluid glucose level is usually measured every 5min. An increased frequency of blood glucose level sampling would cause discomfort for the patient; thus, there is a need for methods to estimate blood glucose levels from the glucose levels measured in subcutaneous tissue. The Steil-Rebrin model is widely used to describe the relationship between blood and interstitial fluid glucose dynamics. However, we measured glucose level patterns for which the Steil-Rebrin model does not hold. Therefore, we based our research on a different model that relates present blood and interstitial fluid glucose levels to future interstitial fluid glucose levels. Using this model, we derived an improved model for calculating blood glucose levels. In the experiments conducted, this model outperformed the Steil-Rebrin model while introducing no additional requirements for glucose sample collection. In subcutaneous tissue, 26.71% of the calculated blood glucose levels had absolute values of relative differences from smoothed measured blood glucose levels less than or equal to 5% using the Steil-Rebrin model. However, the same difference interval was encountered in 63.01% of the calculated blood glucose levels using the proposed model. In addition, 79.45% of the levels calculated with the Steil-Rebrin model compared with 95.21% of the levels calculated with the proposed model had 20% difference intervals. Copyright © 2014 Elsevier Ltd. All rights reserved.
ESTIMATION OF FREE HYDROCARBON VOLUME FROM FLUID LEVELS IN MONITORING WELLS
Under the assumption of local vertical equilibrium, fluid pressure distributions specified from well fluid levels in monitoring wells may be used to predict water and hydrocarbon saturation profiles given expressions for air-water-hydrocarbon saturation-pressure relations. Verti...
Fibrinogen is not elevated in the cerebrospinal fluid of patients with multiple sclerosis
2011-01-01
Background Elevated plasma fibrinogen levels are a well known finding in acute infectious diseases, acute stroke and myocardial infarction. However its role in the cerebrospinal fluid (CSF) of acute and chronic central (CNS) and peripheral nervous system (PNS) diseases is unclear. Findings We analyzed CSF and plasma fibrinogen levels together with routine parameters in patients with multiple sclerosis (MS), acute inflammatory diseases of the CNS (bacterial and viral meningoencephalitis, BM and VM) and PNS (Guillain-Barré syndrome; GBS), as well as in non-inflammatory neurological controls (OND) in a total of 103 patients. Additionally, MS patients underwent cerebral MRI scans at time of lumbar puncture. CSF and plasma fibrinogen levels were significantly lower in patients with MS and OND patients as compared to patients with BM, VM and GBS. There was a close correlation between fibrinogen levels and albumin quotient (rho = 0.769, p < 0.001) which strongly suggests passive transfer of fibrinogen through the blood-CSF-barrier during acute inflammation. Hence, in MS, the prototype of chronic neuroinflammation, CSF fibrinogen levels were not elevated and could not be correlated to clinical and neuroradiological outcome parameters. Conclusions Although previous work has shown clear evidence of the involvement of fibrinogen in MS pathogenesis, this is not accompanied by increased fibrinogen in the CSF compartment. PMID:22029888
Ultrasonic Measurement of Aircraft Strut Hydraulic Fluid Level
NASA Technical Reports Server (NTRS)
Allison, Sidney G.
2002-01-01
An ultrasonic method is presented for non-intrusively measuring hydraulic fluid level in aircraft struts in the field quickly and easily without modifying the strut or aircraft. The technique interrogates the strut with ultrasonic waves generated and received by a removable ultrasonic transducer hand-held on the outside of the strut in a fashion that is in the presence or absence of hydraulic fluid inside the strut. This technique was successfully demonstrated on an A-6 aircraft strut on the carriage at the Aircraft Landing Dynamics Research Facility at NASA Langley Research Center. Conventional practice upon detection of strut problem symptoms is to remove aircraft from service for extensive maintenance to determine fluid level. No practical technique like the method presented herein for locating strut hydraulic fluid level is currently known to be used.
Update on the Mechanisms of Pulmonary Inflammation and Oxidative Imbalance Induced by Exercise.
Araneda, O F; Carbonell, T; Tuesta, M
2016-01-01
The mechanisms involved in the generation of oxidative damage and lung inflammation induced by physical exercise are described. Changes in lung function induced by exercise involve cooling of the airways, fluid evaporation of the epithelial surface, increased contact with polluting substances, and activation of the local and systemic inflammatory response. The present work includes evidence obtained from the different types of exercise in terms of duration and intensity, the effect of both acute performance and chronic performance, and the influence of special conditions such as cold weather, high altitude, and polluted environments. Levels of prooxidants, antioxidants, oxidative damage to biomolecules, and cellularity, as well as levels of soluble mediators of the inflammatory response and its effects on tissues, are described in samples of lung origin. These samples include tissue homogenates, induced sputum, bronchoalveolar lavage fluid, biopsies, and exhaled breath condensate obtained in experimental protocols conducted on animal and human models. Finally, the need to simultaneously explore the oxidative/inflammatory parameters to establish the interrelation between them is highlighted.
Update on the Mechanisms of Pulmonary Inflammation and Oxidative Imbalance Induced by Exercise
Araneda, O. F.; Carbonell, T.; Tuesta, M.
2016-01-01
The mechanisms involved in the generation of oxidative damage and lung inflammation induced by physical exercise are described. Changes in lung function induced by exercise involve cooling of the airways, fluid evaporation of the epithelial surface, increased contact with polluting substances, and activation of the local and systemic inflammatory response. The present work includes evidence obtained from the different types of exercise in terms of duration and intensity, the effect of both acute performance and chronic performance, and the influence of special conditions such as cold weather, high altitude, and polluted environments. Levels of prooxidants, antioxidants, oxidative damage to biomolecules, and cellularity, as well as levels of soluble mediators of the inflammatory response and its effects on tissues, are described in samples of lung origin. These samples include tissue homogenates, induced sputum, bronchoalveolar lavage fluid, biopsies, and exhaled breath condensate obtained in experimental protocols conducted on animal and human models. Finally, the need to simultaneously explore the oxidative/inflammatory parameters to establish the interrelation between them is highlighted. PMID:26881028
Affordable Rankine Cycle Waste Heat Recovery for Heavy Duty Trucks
DOE Office of Scientific and Technical Information (OSTI.GOV)
Subramanian, Swami Nathan
Nearly 30% of fuel energy is not utilized and wasted in the engine exhaust. Organic Rankine Cycle (ORC) based waste heat recovery (WHR) systems offer a promising approach on waste energy recovery and improving the efficiency of Heavy-Duty diesel engines. Major barriers in the ORC WHR system are the system cost and controversial waste heat recovery working fluids. More than 40% of the system cost is from the additional heat exchangers (recuperator, condenser and tail pipe boiler). The secondary working fluid loop designed in ORC system is either flammable or environmentally sensitive. The Eaton team investigated a novel approach tomore » reduce the cost of implementing ORC based WHR systems to Heavy-Duty (HD) Diesel engines while utilizing safest working fluids. Affordable Rankine Cycle (ARC) concept aimed to define the next generation of waste energy recuperation with a cost optimized WHR system. ARC project used engine coolant as the working fluid. This approach reduced the need for a secondary working fluid circuit and subsequent complexity. A portion of the liquid phase engine coolant has been pressurized through a set of working fluid pumps and used to recover waste heat from the exhaust gas recirculation (EGR) and exhaust tail pipe exhaust energy. While absorbing heat, the mixture is partially vaporized but remains a wet binary mixture. The pressurized mixed-phase engine coolant mixture is then expanded through a fixed-volume ratio expander that is compatible with two-phase conditions. Heat rejection is accomplished through the engine radiator, avoiding the need for a separate condenser. The ARC system has been investigated for PACCAR’s MX-13 HD diesel engine.« less
Time-lapse 3-D seismic imaging of shallow subsurface contaminant flow.
McKenna, J; Sherlock, D; Evans, B
2001-12-01
This paper presents a physical modelling study outlining a technique whereby buoyant contaminant flow within water-saturated unconsolidated sand was remotely monitored utilizing the time-lapse 3-D (TL3-D) seismic response. The controlled temperature and pressure conditions, along with the high level of acquisition repeatability attainable using sandbox physical models, allow the TL3-D seismic response to pore fluid movement to be distinguished from all other effects. TL3-D seismic techniques are currently being developed to monitor hydrocarbon reserves within producing reservoirs in an endeavour to improve overall recovery. However, in many ways, sandbox models under atmospheric conditions more accurately simulate the shallow subsurface than petroleum reservoirs. For this reason, perhaps the greatest application for analogue sandbox modelling is to improve our understanding of shallow groundwater and environmental flow mechanisms. Two fluid flow simulations were conducted whereby air and kerosene were injected into separate water-saturated unconsolidated sand models. In both experiments, a base 3-D seismic volume was recorded and compared with six later monitor surveys recorded while the injection program was conducted. Normal incidence amplitude and P-wave velocity information were extracted from the TL3-D seismic data to provide visualization of contaminant migration. Reflection amplitudes displayed qualitative areal distribution of fluids when a suitable impedance contrast existed between pore fluids. TL3-D seismic reflection tomography can potentially monitor the change in areal distribution of fluid contaminants over time, indicating flow patterns. However, other research and this current work have not established a quantifiable relationship between either normal reflection amplitudes and attenuation and fluid saturation. Generally, different pore fluids will have unique seismic velocities due to differences in compressibility and density. The predictable relationships that exist between P-wave velocity and fluid saturation can allow a quantitative assessment of contaminant migration.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Alan Black; Arnis Judzis
2003-10-01
This document details the progress to date on the OPTIMIZATION OF DEEP DRILLING PERFORMANCE--DEVELOPMENT AND BENCHMARK TESTING OF ADVANCED DIAMOND PRODUCT DRILL BITS AND HP/HT FLUIDS TO SIGNIFICANTLY IMPROVE RATES OF PENETRATION contract for the year starting October 2002 through September 2002. The industry cost shared program aims to benchmark drilling rates of penetration in selected simulated deep formations and to significantly improve ROP through a team development of aggressive diamond product drill bit--fluid system technologies. Overall the objectives are as follows: Phase 1--Benchmark ''best in class'' diamond and other product drilling bits and fluids and develop concepts for amore » next level of deep drilling performance; Phase 2--Develop advanced smart bit--fluid prototypes and test at large scale; and Phase 3--Field trial smart bit--fluid concepts, modify as necessary and commercialize products. Accomplishments to date include the following: 4Q 2002--Project started; Industry Team was assembled; Kick-off meeting was held at DOE Morgantown; 1Q 2003--Engineering meeting was held at Hughes Christensen, The Woodlands Texas to prepare preliminary plans for development and testing and review equipment needs; Operators started sending information regarding their needs for deep drilling challenges and priorities for large-scale testing experimental matrix; Aramco joined the Industry Team as DEA 148 objectives paralleled the DOE project; 2Q 2003--Engineering and planning for high pressure drilling at TerraTek commenced; 3Q 2003--Continuation of engineering and design work for high pressure drilling at TerraTek; Baker Hughes INTEQ drilling Fluids and Hughes Christensen commence planning for Phase 1 testing--recommendations for bits and fluids.« less
Art, Tatiana; Franck, Thierry; Lekeux, Pierre; de Moffarts, Brieuc; Couëtil, Laurent; Becker, Martine; Kohnen, Serge; Deby-Dupont, Ginette; Serteyn, Didier
2006-01-01
The aim of this work was to measure the myeloperoxidase (MPO) concentration in bronchoalveolar lavage (BAL) fluid collected from horses with recurrent airway obstruction (RAO), both in crisis and in remission, as well as from healthy horses. Seven horses with RAO were exposed to moldy hay until the maximum change in pleural pressure was greater than 1.5 kPa. At that point, BAL was performed, and the total cell counts and percentages in the fluid were immediately determined. To measure the MPO concentration in BAL-fluid supernatant, we used a specific enzyme-linked immunosorbent assay with polyclonal antibodies against equine MPO. The tests were repeated on the horses with RAO after they had spent 2 mo on pasture. Six healthy horses serving as controls underwent the same tests. The absolute and relative neutrophil counts and the MPO concentration in the BAL fluid were significantly greater in the horses with an RAO crisis than in the control horses. After 2 mo on pasture, the horses that had been in RAO crisis were clinically normal, and their neutrophil counts and MPO levels in BAL fluid had significantly decreased; during remission their neutrophil counts were not significantly different from those in the healthy horses, but their MPO concentration remained significantly higher. This study showed that determining the MPO concentration in a horse’s BAL fluid is technically possible and that during remission from RAO the concentration remains higher than normal. Thus, MPO may be a marker of neutrophil presence and activation in the lower airways. PMID:17042382
Element mobilization from Bakken shales as a function of water chemistry.
Wang, Lin; Burns, Scott; Giammar, Daniel E; Fortner, John D
2016-04-01
Waters that return to the surface after injection of a hydraulic fracturing fluid for gas and oil production contain elements, including regulated metals and metalloids, which are mobilized through interactions between the fracturing fluid and the shale formation. The rate and extent of mobilization depends on the geochemistry of the formation and the chemical characteristics of the fracturing fluid. In this work, laboratory scale experiments investigated the influence of water chemistry on element mobilization from core samples taken from the Bakken formation, one of the most productive shale oil plays in the US. Fluid properties were systematically varied and evaluated with regard to pH, oxidant level, solid:water ratio, temperature, and chemical additives. Element mobilization strongly depended on solution pH and redox conditions and to a lesser extent on the temperature and solid:water ratio. The presence of oxygen and addition of hydrogen peroxide or ammonium persulfate led to pyrite oxidation, resulting in elevated sulfate concentrations. Further, depending on the mineral carbonates available to buffer the system pH, pyrite oxidation could lower the system pH and enhance the mobility of several metals and metalloids. Copyright © 2016 Elsevier Ltd. All rights reserved.
Shen, Yanfei; Huang, Xinmei; Zhang, Weimin
2017-05-12
Compared to positive fluid balance (FB), negative FB is associated with improved clinical outcomes in critically ill patients. However, as to whether achieving more negative FB can further improve outcomes has not been investigated. This study aimed to investigate whether more negative FB and restricted fluid intake were associated with improved outcomes in critically ill patients. Data were extracted from the Multi-parameter Intelligent Monitoring in Intensive Care III Database. Patients achieving negative FB at 48 hours after intensive care unit (ICU) admission were screened. The primary outcome was hospital mortality. Logistic models were built to explore the association between FB, fluid intake and mortality, using FB and fluid intake (both four levels) as design variables and using the linear spline function method. There were 2068 patients meeting the inclusion criteria. Compared to slight negative FB (level 1), there was a decreased tendency towards mortality with FB level 2 (OR 0.88, 95% CI 0.69-1.11) and level 3 (OR 0.79, 95% CI 0. 65-1.11); however, only extreme negative FB (level 4) was significant (OR 0.56, 95% CI 0. 33-0.95). Fluid intake and urine output were evenly distributed over the first 48 hours after ICU admission. Fluid intake was inversely associated with hospital mortality, with the OR decreased stepwise from level 2 (OR 0.73, 95% CI 0.56-0.96) to level 4 (OR 0.47, 95% CI 0.30-0.74), referred to level 1. Urine output also showed a similar pattern. Diuretic use was associated with higher mortality in both models. In critically ill patients with negative FB, both increased fluid intake and urine output were associated with decreased hospital mortality. However, compared to slight FB, achieving more negative FB was not associated with reduced mortality.
Overview of MSFC's Applied Fluid Dynamics Analysis Group Activities
NASA Technical Reports Server (NTRS)
Garcia, Roberto; Wang, Tee-See; Griffin, Lisa; Turner, James E. (Technical Monitor)
2001-01-01
This document is a presentation graphic which reviews the activities of the Applied Fluid Dynamics Analysis Group at Marshall Space Flight Center (i.e., Code TD64). The work of this group focused on supporting the space transportation programs. The work of the group is in Computational Fluid Dynamic tool development. This development is driven by hardware design needs. The major applications for the design and analysis tools are: turbines, pumps, propulsion-to-airframe integration, and combustion devices.
Intermediate Temperature Fluids Life Tests - Theory
NASA Technical Reports Server (NTRS)
Tarau, Calin; Sarraf, David B.; Locci, Ivan E.; Anderson, William G.
2008-01-01
There are a number of different applications that could use heat pipes or loop heat pipes (LHPs) in the intermediate temperature range of 450 to 750 K, including space nuclear power system radiators, and high temperature electronics cooling. Potential working fluids include organic fluids, elements, and halides, with halides being the least understood, with only a few life tests conducted. Potential envelope materials for halide working fluids include pure aluminum, aluminum alloys, commercially pure (CP) titanium, titanium alloys, and corrosion resistant superalloys. Life tests were conducted with three halides (AlBr3, SbBr3, and TiCl4) and water in three different envelopes: two aluminum alloys (Al-5052, Al-6061) and Cp-2 titanium. The AlBr3 attacked the grain boundaries in the aluminum envelopes, and formed TiAl compounds in the titanium. The SbBr3 was incompatible with the only envelope material that it was tested with, Al-6061. TiCl4 and water were both compatible with CP2-titanium. A theoretical model was developed that uses electromotive force differences to predict the compatibility of halide working fluids with envelope materials. This theory predicts that iron, nickel, and molybdenum are good envelope materials, while aluminum and titanium halides are good working fluids. The model is in good agreement with results form previous life tests, as well as the current life tests.
Rheological properties of magnetorheological polishing fluid featuring plate-like iron particles
NASA Astrophysics Data System (ADS)
Shah, Kruti; Choi, Seung-Bok
2014-10-01
In this work, magnetorheological polishing fluid (MRP) rheological properties are experimentally investigated for bi-disperse suspension of plate-like iron particles and non-magnetic abrasive particles dispersed in carrier fluid to see the influence of small-sized non-magnetic particle on the large-size Mr fluid. As a first step, structural and morphology of iron plate-like particles are described in details. The rheological properties are then characterized using magnetorheometer. Particle size and volume fraction of both particles play an important role during the breaking and reforming the structure under application of magnetic field which influence on the rheological properties of MRP fluid. Three different constitutive models, such as the Bingham, Herschel-Bulkley and Casson equations are considered to evaluate their predictive capability of apparent viscosity of proposed MRP fluid. The yield stress increases with increasing magnetic field strength. The results obtained from three models show that the flow index exhibits shear thinning behavior of fluid. A comparative work between the model results and experimental results is also undertaken.
Aleyasin, Ashraf; Hosseini, Marzieh Agha; Mahdavi, Atossa; Safdarian, Leila; Fallahi, Parvin; Mohajeri, Mohammad Reza; Abbasi, Mohammad; Esfahani, Fatemeh
2011-11-01
To assess the correlation between the levels of vitamin D in follicular fluid and serum, and to determine whether the level of 25-hydroxyvitamin D (25OH-D) in follicular fluid of infertile women undergoing assisted reproductive technology (ART) is associated with the outcome. Eighty-two infertile women undergoing ART at an academic tertiary care centre were recruited for a prospective cohort study. Levels of 25OH-D in follicular fluid and serum were measured. Standardized regimens for pituitary downregulation and controlled ovarian hyperstimulation were employed. Patient and cycle parameters, and clinical pregnancy (defined as evidence of intra-uterine gestation sac plus heart rate on ultrasound) were determined. A significant correlation was found between the levels of vitamin D in follicular fluid and serum (r=0.767, p=0.001). The overall rates of chemical, clinical and ongoing pregnancy were 35.5% (n=29), 29.3% (n=24) and 23.2% (n=19), respectively. No significant difference was found in these pregnancy rates between the tertiles of 25OH-D level in follicular fluid (p=0.959, 0.995 and 0.604, respectively). The median serum level of vitamin D was 8.13 (range 5.37-13.62)ng/ml in the clinically pregnant group and 8.29 (range 5.93-21.23)ng/ml in the non-pregnant group (p=0.235). Interestingly, the median level of vitamin D in follicular fluid was 9.19 (range 5.25-19.51)ng/ml in the clinically pregnant group and 10.34 (range 5.89-29.69)ng/ml in the non-pregnant group (p=0.433). The fertilization rate decreased significantly and the implantation rate increased (not significantly) with increasing tertiles of 25OH-D level in follicular fluid. The level of 25OH-D in follicular fluid is reflective of body stores of vitamin D. Most subjects in this study were deficient in vitamin D, but this study found that vitamin D deficiency does not play a pivotal role in the outcome of ART. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Corrosion inhibitor for aqueous ammonia absorption system
Phillips, Benjamin A.; Whitlow, Eugene P.
1998-09-22
A method of inhibiting corrosion and the formation of hydrogen and thus improving absorption in an ammonia/water absorption refrigeration, air conditioning or heat pump system by maintaining the hydroxyl ion concentration of the aqueous ammonia working fluid within a selected range under anaerobic conditions at temperatures up to 425.degree. F. This hydroxyl ion concentration is maintained by introducing to the aqueous ammonia working fluid an inhibitor in an amount effective to produce a hydroxyl ion concentration corresponding to a normality of the inhibitor relative to the water content ranging from about 0.015 N to about 0.2 N at 25.degree. C. Also, working fluids for inhibiting the corrosion of carbon steel and resulting hydrogen formation and improving absorption in an ammonia/water absorption system under anaerobic conditions at up to 425.degree. F. The working fluids may be aqueous solutions of ammonia and a strong base or aqueous solutions of ammonia, a strong base, and a specified buffer.
Corrosion inhibitor for aqueous ammonia absorption system
Phillips, B.A.; Whitlow, E.P.
1998-09-22
A method is described for inhibiting corrosion and the formation of hydrogen and thus improving absorption in an ammonia/water absorption refrigeration, air conditioning or heat pump system by maintaining the hydroxyl ion concentration of the aqueous ammonia working fluid within a selected range under anaerobic conditions at temperatures up to 425 F. This hydroxyl ion concentration is maintained by introducing to the aqueous ammonia working fluid an inhibitor in an amount effective to produce a hydroxyl ion concentration corresponding to a normality of the inhibitor relative to the water content ranging from about 0.015 N to about 0.2 N at 25 C. Also, working fluids for inhibiting the corrosion of carbon steel and resulting hydrogen formation and improving absorption in an ammonia/water absorption system under anaerobic conditions at up to 425 F. The working fluids may be aqueous solutions of ammonia and a strong base or aqueous solutions of ammonia, a strong base, and a specified buffer. 5 figs.
Open Loop Heat Pipe Radiator Having a Free-Piston for Wiping Condensed Working Fluid
NASA Technical Reports Server (NTRS)
Weinstein, Leonard M. (Inventor)
2015-01-01
An open loop heat pipe radiator comprises a radiator tube and a free-piston. The radiator tube has a first end, a second end, and a tube wall, and the tube wall has an inner surface and an outer surface. The free-piston is enclosed within the radiator tube and is capable of movement within the radiator tube between the first and second ends. The free-piston defines a first space between the free-piston, the first end, and the tube wall, and further defines a second space between the free-piston, the second end, and the tube wall. A gaseous-state working fluid, which was evaporated to remove waste heat, alternately enters the first and second spaces, and the free-piston wipes condensed working fluid from the inner surface of the tube wall as the free-piston alternately moves between the first and second ends. The condensed working fluid is then pumped back to the heat source.
NASA Astrophysics Data System (ADS)
Abolghasemi, Mehran; Keshavarz, Ali; Mehrabian, Mozaffar Ali
2012-11-01
The thermal storage unit consists of two concentric cylinders where the working fluid flows through the internal cylinder and the annulus is filled with a phase change material. The system carries out a cyclic operation; each cycle consists of two processes. In the charging process the hot working fluid enters the internal cylinder and transfers heat to the phase change material. In the discharging process the cold working fluid enters the internal cylinder and absorbs heat from the phase change material. The differential equations governing the heat transfer between the two media are solved numerically. The numerical results are compared with the experimental results available in the literature. The performance of an energy storage unit is directly related to the thermal conductivity of nano-particles. The energy consumption of a residential unit whose energy is supplied by a thermal storage system can be reduced by 43 % when using nano-particles.
Metalworking fluid-associated hypersensitivity pneumonitis: a workshop summary.
Kreiss, K; Cox-Ganser, J
1997-10-01
A workshop discussing eight clusters of hypersensitivity pneumonitis in the automotive industry among metalworking fluid-exposed workers concluded that a risk exists for this granulomatous lung disease where water-based fluids are used and unusual microbial contaminants predominate. Strong candidates for microbial etiology are nontuberculous mycobacteria and fungi. Cases of hypersensitivity pneumonitis occur among cases with other work-related respiratory symptoms and chest diseases. Reversibility of disease has occurred in many cases with exposure cessation, allowing return to work to jobs without metalworking fluid exposures or, in some situations, to jobs without the same metalworking fluid exposures. Cases have been recognized with metalworking fluid exposures generally less than 0.5 mg/m3. The workshop participants identified knowledge gaps regarding risk factors, exposure-response relationships, intervention efficacy, and natural history, as well as surveillance needs to define the extent of the problem in this industry. In the absence of answers to these questions, guidance for prevention is necessarily limited.
NASA Astrophysics Data System (ADS)
Phu, Do Xuan; Choi, Seung-Bok
2015-02-01
In this work, a new high-load magnetorheological (MR) fluid mount system is devised and applied to control vibration in a ship engine. In the investigation of vibration-control performance, a new modified indirect fuzzy sliding mode controller is formulated and realized. The design of the proposed MR mount is based on the flow mode of MR fluid, and it includes two separated coils for generating a magnetic field. An optimization process is carried out to achieve maximal damping force under certain design constraints, such as the allowable height of the mount. As an actuating smart fluid, a new plate-like iron-particle-based MR fluid is used, instead of the conventional spherical iron-particle-based MR fluid. After evaluating the field-dependent yield stress of the MR fluid, the field-dependent damping force required to control unwanted vibration in the ship engine is determined. Subsequently, an appropriate-sized MR mount is manufactured and its damping characteristics are evaluated. After confirming the sufficient damping force level of the manufactured MR mount, a medium-sized ship engine mount system consisting of eight MR mounts is established, and its dynamic governing equations are derived. A new modified indirect fuzzy sliding mode controller is then formulated and applied to the engine mount system. The displacement and velocity responses show that the unwanted vibrations of the ship engine system can be effectively controlled in both the axial and radial directions by applying the proposed control methodology.
Pino, Ana María; Ríos, Susana; Astudillo, Pablo; Fernández, Mireya; Figueroa, Paula; Seitz, Germán; Rodríguez, J Pablo
2010-03-01
Osteoporosis is characterized by low bone mass, microarchitectural deterioration of bone tissue leading to increased bone fragility, and a resulting susceptibility to fractures. Distinctive environmental bone marrow conditions appear to support the development and maintenance of the unbalance between bone resorption and bone formation; these complex bone marrow circumstances would be reflected in the fluid surrounding bone marrow cells. The content of regulatory molecules in the extracellular fluid from the human bone marrow is practically unknown. Since the content of cytokines such as adiponectin, leptin, osteoprogeterin (OPG), soluble receptor activator of nuclear factor kappaB ligand (s-RANKL), tumor necrosis factor alpha, and interleukin 6 (IL-6) may elicit conditions promoting or sustaining osteoporosis, in this work we compared the concentrations of the above-mentioned cytokines and also the level of the soluble receptors for both IL-6 and leptin in the extracellular fluid from the bone marrow of nonosteoporotic and osteoporotic human donors. A supernatant fluid (bone marrow supernatant fluid [BMSF]) was obtained after spinning the aspirated bone marrow samples; donors were classified as nonosteoporotic or osteoporotic after dual-energy X-ray absorptiometry (DXA) measuring. Specific commercially available kits were used for all measurements. The cytokines' concentration in BMSF showed differently among nonosteoporotic and osteoporotic women; this last group was characterized by higher content of proinflammatory and adipogenic cytokines. Also, osteoporotic BMSF differentiated by decreased leptin bioavailability, suggesting that insufficient leptin action may distinguish the osteoporotic bone marrow. Copyright 2010 American Society for Bone and Mineral Research.
Kurgan, Ş; Önder, C; Balcı, N; Fentoğlu, Ö; Eser, F; Balseven, M; Serdar, M A; Tatakis, D N; Günhan, M
2017-06-01
The aim of this study was to evaluate the effect of nonsurgical periodontal therapy on clinical parameters and gingival crevicular fluid levels of tissue/blood vessel-type plasminogen activator (t-PA) and plasminogen activator inhibitor-2 (PAI-2) in patients with periodontitis, with or without rheumatoid arthritis (RA). Fifteen patients with RA and chronic periodontitis (RA-P), 15 systemically healthy patients with chronic periodontitis (H-P) and 15 periodontally and systemically healthy volunteers (C) were included in the study. Plaque index, gingival index, probing pocket depth, clinical attachment level, bleeding on probing, gingival crevicular fluid t-PA and PAI-2 levels, erythrocyte sedimentation rate, serum C-reactive protein and disease activity score were evaluated at baseline and 3 mo after mechanical nonsurgical periodontal therapy. All periodontal clinical parameters were significantly higher in the RA-P and H-P groups compared with the C group (p < 0.001) and decreased significantly after treatment (p < 0.001). Pretreatment t-PA levels were highest in the RA-P group and significantly decreased post-treatment (p = 0.047). Pre- and post-treatment PAI-2 levels were significantly lower in controls compared with both periodontitis groups (p < 0.05). Gingival crevicular fluid volume and the levels of t-PA and PAI-2 were significantly correlated. In patients with periodontitis and RA, nonsurgical periodontal therapy reduced the pretreatment gingival crevicular fluid t-PA levels, which were significantly correlated with gingival crevicular fluid PAI-2 levels. The significantly higher t-PA and PAI-2 gingival crevicular fluid levels in periodontal patients, regardless of systemic status, suggest that the plasminogen activating system plays a role in the disease process of periodontitis. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Fully-Coupled Fluid/Structure Vibration Analysis Using MSC/NASTRAN
NASA Technical Reports Server (NTRS)
Fernholz, Christian M.; Robinson, Jay H.
1996-01-01
MSC/NASTRAN's performance in the solution of fully-coupled fluid/structure problems is evaluated. NASTRAN is used to perform normal modes (SOL 103) and forced-response analyses (SOL 108, 111) on cylindrical and cubic fluid/structure models. Bulk data file cards unique to the specification of a fluid element are discussed and analytic partially-coupled solutions are derived for each type of problem. These solutions are used to evaluate NASTRAN's solutions for accuracy. Appendices to this work include NASTRAN data presented in fringe plot form, FORTRAN source code listings written in support of this work, and NASTRAN data file usage requirements for each analysis.
NASA Astrophysics Data System (ADS)
Sánchez, D.; Muñoz de Escalona, J. M.; Monje, B.; Chacartegui, R.; Sánchez, T.
This article presents a novel proposal for complex hybrid systems comprising high temperature fuel cells and thermal engines. In this case, the system is composed by a molten carbonate fuel cell with cascaded hot air turbine and Organic Rankine Cycle (ORC), a layout that is based on subsequent waste heat recovery for additional power production. The work will credit that it is possible to achieve 60% efficiency even if the fuel cell operates at atmospheric pressure. The first part of the analysis focuses on selecting the working fluid of the Organic Rankine Cycle. After a thermodynamic optimisation, toluene turns out to be the most efficient fluid in terms of cycle performance. However, it is also detected that the performance of the heat recovery vapour generator is equally important, what makes R245fa be the most interesting fluid due to its balanced thermal and HRVG efficiencies that yield the highest global bottoming cycle efficiency. When this fluid is employed in the compound system, conservative operating conditions permit achieving 60% global system efficiency, therefore accomplishing the initial objective set up in the work. A simultaneous optimisation of gas turbine (pressure ratio) and ORC (live vapour pressure) is then presented, to check if the previous results are improved or if the fluid of choice must be replaced. Eventually, even if system performance improves for some fluids, it is concluded that (i) R245fa is the most efficient fluid and (ii) the operating conditions considered in the previous analysis are still valid. The work concludes with an assessment about safety-related aspects of using hydrocarbons in the system. Flammability is studied, showing that R245fa is the most interesting fluid also in this regard due to its inert behaviour, as opposed to the other fluids under consideration all of which are highly flammable.
Schiave, Letícia Aparecida; Nascimento, Erika; Vilar, Fernando Crivelenti; de Haes, Tissiana Marques; Takayanagui, Osvaldo Massaiti; Gaitani, Cristiane Masetto de; Martinez, Roberto
Fluconazole is extensively used for the treatment of candidiasis and cryptococcosis. Among other factors, successful treatment is related to appropriate fluconazole levels in blood and cerebrospinal fluid. In the present study, fluconazole levels were determined in 15 patients, 14 of whom had AIDS and 13 had neurocryptococcosis. The only selection criterion was treatment with fluconazole, which was performed with a generic or similar form of the drug. Fluconazole level was determined by high performance liquid chromatography and the susceptibility profile of Cryptococcus spp. isolated from the patients was assessed by broth microdilution. Blood and cerebrospinal fluid fluconazole levels were found to be related to the fluconazole daily dose, and exceeded the minimum inhibitory concentration of this antifungal for the Cryptococcus spp. isolates. A good correlation was observed between serum and cerebrospinal fluid drug concentration. In conclusion, treatment with non-original fluconazole under usual medical practice conditions results in appropriate blood and cerebrospinal fluid levels of the drug for inhibiting Cryptococcus spp. susceptible to this antifungal drug. The relatively common failures of neurocryptococcosis treatment appear not to be due to insufficient fluconazole levels in the cerebrospinal fluid, especially with the use of daily doses of 400-800mg. Copyright © 2017 Sociedade Brasileira de Infectologia. Published by Elsevier Editora Ltda. All rights reserved.
Sinking bubbles in stout beers
NASA Astrophysics Data System (ADS)
Lee, W. T.; Kaar, S.; O'Brien, S. B. G.
2018-04-01
A surprising phenomenon witnessed by many is the sinking bubbles seen in a settling pint of stout beer. Bubbles are less dense than the surrounding fluid so how does this happen? Previous work has shown that the explanation lies in a circulation of fluid promoted by the tilted sides of the glass. However, this work has relied heavily on computational fluid dynamics (CFD) simulations. Here, we show that the phenomenon of sinking bubbles can be predicted using a simple analytic model. To make the model analytically tractable, we work in the limit of small bubbles and consider a simplified geometry. The model confirms both the existence of sinking bubbles and the previously proposed mechanism.
Pradeep, A R; Manjunath, R G Shiva; Kathariya, Rahul
2010-11-01
Increased C-reactive protein levels have been found in all active inflammations, including periodontitis. This study aims to assess the C-reactive protein levels in periodontal disease progression. Forty-five patients were divided into the following three groups (n=15) based on gingival index, probing pocket depth, and clinical attachment level: healthy (group I), gingivitis (group II), and chronic periodontitis (group III). Gingival crevicular fluid and serum samples were quantified for C-reactive protein using enzyme-linked immunosorbent assay. The mean C-reactive protein concentration in gingival crevicular fluid and serum was found to be highest in group III (1233.33ng/mL for gingival crevicular fluid, 5483.33ng/mL for serum), and least in group I (60 ng/mL and 413 ng/mL for gingival crevicular fluid and serum, respectively) The mean C-reactive protein concentration in group II (453.33ng/mL for gingival crevicular fluid and 3565.33 ng/mL for serum) was found to be intermediate. C-reactive protein levels in gingival crevicular fluid and serum increased proportionately with the severity of periodontal disease. They correlated positively with clinical parameters, including gingival index, probing pocket depth, and clinical attachment level. Thus, it can be considered as a periodontal inflammatory biomarker and deserves further consideration. © 2010 Blackwell Publishing Asia Pty Ltd.
Endotoxin in Size-Separated Metal Working Fluid Aerosol Particles.
Dahlman-Höglund, Anna; Lindgren, Åsa; Mattsby-Baltzer, Inger
2016-08-01
Patients with airway symptoms working in metal working industries are increasing, despite efforts to improve the environmental air surrounding the machines. Our aim was to analyse the amount of endotoxin in size-separated airborne particles of metal working fluid (MWF) aerosol, by using the personal sampler Sioutas cascade impactor, to compare filter types, and to compare the concentration of airborne endotoxin to that of the corresponding MWFs. In a pilot field study, aerosols were collected in two separate machine halls on totally 10 occasions, using glass fibre and polytetrafluoroethylene (PTFE) filters in parallel at each station. Airborne endotoxin was distributed over all size fractions. While a major part was found in the largest size fraction (72%, 2.5-10 µm), up to 8% of the airborne endotoxin was detected in the smallest size fraction (<0.25 µm). Comparing the efficiency of the filter types, a significantly higher median endotoxin level was found with glass fibres filters collecting the largest particle-size fraction (1.2-fold) and with PTFE filters collecting the smallest ones (5-fold). The levels of endotoxin in the size-separated airborne particle fractions correlated to those of the MWFs supporting the aerosol-generating machines. Our study indicates that a significant part of inhalable aerosols of MWFs consists of endotoxin-containing particles below the size of intact bacteria, and thus small enough to readily reach the deepest part of the lung. Combined with other chemical irritants of the MWF, exposure to MWF aerosols containing endotoxin pose a risk to respiratory health problems. © The Author 2016. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.
Burbank works at the LMM in the FIR/FCF in the U.S. Laboratory
2011-12-01
ISS030-E-007428 (1 Dec. 2011) --- NASA astronaut Dan Burbank, Expedition 30 commander, works at the Light Microscopy Module (LMM) in the Fluids Integrated Rack / Fluids Combustion Facility (FIR/FCF) located in the Destiny laboratory of the International Space Station.
Burbank works at the LMM in the FIR/FCF in the U.S. Laboratory
2011-12-01
ISS030-E-007426 (1 Dec. 2011) --- NASA astronaut Dan Burbank, Expedition 30 commander, works at the Light Microscopy Module (LMM) in the Fluids Integrated Rack / Fluids Combustion Facility (FIR/FCF) located in the Destiny laboratory of the International Space Station.
Burbank works at the LMM in the FIR/FCF in the U.S. Laboratory
2011-12-01
ISS030-E-007429 (1 Dec. 2011) --- NASA astronaut Dan Burbank, Expedition 30 commander, works at the Light Microscopy Module (LMM) in the Fluids Integrated Rack / Fluids Combustion Facility (FIR/FCF) located in the Destiny laboratory of the International Space Station.
2016-10-01
PRINCIPAL INVESTIGATOR: Nicholas Theodore, MD CONTRACTING ORGANIZATION: Dignity Health San Francisco, CA 94107-1773 REPORT DATE: October 2016...nicholas.theodore@bnaneuro.net 5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) Dignity Health 8. PERFORMING ORGANIZATION REPORT...and query resolution. As new study staff are assigned to the study on the site-level, the CRO provides remote training to familiarize them with the
Responsive copolymers for enhanced petroleum recovery
DOE Office of Scientific and Technical Information (OSTI.GOV)
McCormick, Charles; Hester, Roger
The objectives of this work were to: synthesize responsive, amphiphilic systems; characterize molecular structure and solution behavior; measure rheological properties of the aqueous fluids including behavior in fixed geometry flow profiles and beds; and to tailor final polymer compositions for in situ rheology control under simulated reservoir conditions. This report focuses on the first phase of the research emphasizing synthesis and the development of photophysical techniques and rheological means of following segmental organization at the structural level.
Fabrication Materials for a Closed Cycle Brayton Turbine Wheel
NASA Technical Reports Server (NTRS)
Khandelwal, Suresh; Hah, Chunill; Powers, Lynn M.; Stewart, Mark E.; Suresh, Ambady; Owen, Albert K.
2006-01-01
A multidisciplinary analysis of a radial inflow turbine rotor is presented. This work couples high-fidelity fluid, structural, and thermal simulations in a seamless multidisciplinary analysis to investigate the consequences of material selection. This analysis extends multidisciplinary techniques previously demonstrated on rocket turbopumps and hypersonic engines. Since no design information is available for the anticipated Brayton rotating machinery, an existing rotor design (the Brayton Rotating Unit (BRU)) was used in the analysis. Steady state analysis results of a notional turbine rotor indicate that stress levels are easily manageable at the turbine inlet temperature, and stress levels anticipated using either superalloys or ceramics.
Large-eddy simulation of a stratocumulus cloud
DOE Office of Scientific and Technical Information (OSTI.GOV)
Matheou, Georgios; Chung, Daniel; Teixeira, João
This paper is associated with a poster winner of a 2016 APS/DFD Gallery of Fluid Motion Award for work presented at the DFD Gallery of Fluid Motion. The original poster is available from the Gallery of Fluid Motion,
Large-eddy simulation of a stratocumulus cloud
Matheou, Georgios; Chung, Daniel; Teixeira, João
2017-09-29
This paper is associated with a poster winner of a 2016 APS/DFD Gallery of Fluid Motion Award for work presented at the DFD Gallery of Fluid Motion. The original poster is available from the Gallery of Fluid Motion,
Thin-Film Magnetic-Field-Response Fluid-Level Sensor for Non-Viscous Fluids
NASA Technical Reports Server (NTRS)
Woodard, Stanley E.; Shams, Qamar A.; Fox, Robert L.; Taylor, Bryant D.
2008-01-01
An innovative method has been developed for acquiring fluid-level measurements. This method eliminates the need for the fluid-level sensor to have a physical connection to a power source or to data acquisition equipment. The complete system consists of a lightweight, thin-film magnetic-field-response fluid-level sensor (see Figure 1) and a magnetic field response recorder that was described in Magnetic-Field-Response Measurement-Acquisition System (LAR-16908-1), NASA Tech Briefs, Vol. 30, No. 6 (June 2006), page 28. The sensor circuit is a capacitor connected to an inductor. The response recorder powers the sensor using a series of oscillating magnetic fields. Once electrically active, the sensor responds with its own harmonic magnetic field. The sensor will oscillate at its resonant electrical frequency, which is dependent upon the capacitance and inductance values of the circuit.
Current Results and Proposed Activities in Microgravity Fluid Dynamics
NASA Technical Reports Server (NTRS)
Polezhaev, V. I.
1996-01-01
The Institute for Problems in Mechanics' Laboratory work in mathematical and physical modelling of fluid mechanics develops models, methods, and software for analysis of fluid flow, instability analysis, direct numerical modelling and semi-empirical models of turbulence, as well as experimental research and verification of these models and their applications in technological fluid dynamics, microgravity fluid mechanics, geophysics, and a number of engineering problems. This paper presents an overview of the results in microgravity fluid dynamics research during the last two years. Nonlinear problems of weakly compressible and compressible fluid flows are discussed.
Influence of follicular fluid GDF9 and BMP15 on embryo quality.
Gode, Funda; Gulekli, Bulent; Dogan, Erbil; Korhan, Peyda; Dogan, Seda; Bige, Ozgur; Cimrin, Dilek; Atabey, Nese
2011-06-01
To evaluate the association between follicular fluid levels of propeptide and mature forms of growth differentiation factor (GDF) 9 and bone morphogenetic protein (BMP) 15 with subsequent oocyte and embryo quality. Prospective clinical study. University hospital. Eighty-one infertile patients who underwent in vitro fertilization (IVF)/intracytoplasmic sperm injection (ICSI). The expression levels of the propeptide and mature forms of follicular fluid GDF9 and BMP15 were determined by western blot analysis. The levels of follicular fluid hormones (FSH, E2, and P) were measured with automated chemiluminescent enzyme immunoassays. The relationships between the levels of GDF9 and BMP15, hormones, oocyte maturation, and embryo quality. Mature GDF9 levels were significantly correlated with the nuclear maturation of oocytes. The mean mature GDF9 level was 4.87±0.60 in the high-embryo-quality group and 1.45±0.81 in the low-embryo-quality group. There were no statistically significant differences in embryo quality among the patients regarding propeptide GDF9 and BMP15 expression status. There was a negative correlation between follicular fluid levels of P and the mature form of GDF9. Higher mature GDF9 levels in the follicular fluid were significantly correlated with oocyte nuclear maturation and embryo quality. Copyright © 2011 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.
Los, Ferdinand; Brodska, Helena
2016-01-01
Background The requirements for magnesium (Mg) supplementation increase under regional citrate anticoagulation (RCA) because citrate acts by chelation of bivalent cations within the blood circuit. The level of magnesium in commercially available fluids for continuous renal replacement therapy (CRRT) may not be sufficient to prevent hypomagnesemia. Methods Patients (n = 45) on CRRT (2,000 ml/h, blood flow (Qb) 100 ml/min) with RCA modality (4% trisodium citrate) using calcium free fluid with 0.75 mmol/l of Mg with additional magnesium substitution were observed after switch to the calcium-free fluid with magnesium concentration of 1.50 mmol/l (n = 42) and no extra magnesium replenishment. All patients had renal indications for CRRT, were treated with the same devices, filters and the same postfilter ionized calcium endpoint (<0.4 mmol/l) of prefilter citrate dosage. Under the high level Mg fluid the Qb, dosages of citrate and CRRT were consequently escalated in 9h steps to test various settings. Results Median balance of Mg was -0.91 (-1.18 to -0.53) mmol/h with Mg 0.75 mmol/l and 0.2 (0.06–0.35) mmol/h when fluid with Mg 1.50 mmol/l was used. It was close to zero (0.02 (-0.12–0.18) mmol/h) with higher blood flow and dosage of citrate, increased again to 0.15 (-0.11–0.25) mmol/h with 3,000 ml/h of high magnesium containing fluid (p<0.001). The arterial levels of Mg were mildly increased after the change for high level magnesium containing fluid (p<0.01). Conclusions Compared to ordinary dialysis fluid the mildly hypermagnesemic fluid provided even balances and adequate levels within ordinary configurations of CRRT with RCA and without a need for extra magnesium replenishment. Trial Registration ClinicalTrials.gov Identifier: NCT01361581 PMID:27391902
Eldin, Eman N.; Omar, Asmaa; Khairy, Mahmoud; Mekawy, Adel H. M.; Ghanem, Maha K.
2012-01-01
BACKGROUND: Noninvasive diagnosis of pleural tuberculosis (TB) remains a challenge due to the paucibacillary nature of the disease. As Mycobacterium tuberculosis (MTB)-specific T cells are recruited into pleural space in TB effusion; their indirect detection may provide useful clinical information. OBJECTIVES: Evaluation of pleural fluid interferon (INF)-γ levels vs Quantiferon–TB Gold In tube assay (QFT- IT) in blood and its adapted variants, using pleural fluid or isolated pleural fluid cells in the diagnosis of pleural TB. METHODS: Thirty-eight patients with pleural effusion of unknown etiology presented at Assiut University Hospital, Egypt, were recruited. Blood and pleural fluid were collected at presentation for INF-γ assays. Ex vivo pleural fluid INF-γ levels, QFT-IT in blood and its adapted variants were compared with final diagnosis as confirmed by other tools including blind and/or thoracoscopic pleural biopsy. RESULTS: The final clinical diagnosis was TB in 20 (53%), malignancy in 10 (26%), and effusion due to other causes in eight patients (21%). Ex vivo pleural fluid INF-γ levels accurately identified TB in all patients and were superior to the QFT-IT assays using blood or pleural fluid (70 and 78% sensitivity, with 60 and 83% specificity, respectively). QFT-IT assay applied to isolated pleural fluid cells had 100% sensitivity and 72% specificity. The optimal cut-off obtained with ROC analysis was 0.73 for TB Gold assay in blood assay, 0.82 IU/ml for the cultured pleural fluid assay, and 0.94 for isolated pleural cells assay. CONCLUSION: The ex vivo pleural fluid INF-γ level is an accurate marker for the diagnosis of pleural TB. QFT- IT assay in peripheral blood or its adapted versions of the assay using pleural fluid and/or washed pleural fluid cells had no diagnostic advantage over pleural fluid INF-γ in the diagnosis of pleural TB. PMID:23189099
Williams working on the JAXA MS (Marangoni Surface) Experiment
2009-11-05
ISS021-E-020299 (5 Nov. 2009) --- NASA astronaut Jeffrey Williams, Expedition 21 flight engineer, works with Fluid Physics Experiment Facility/Marangoni Surface (FPEF MS) Core hardware in the Kibo laboratory of the International Space Station. The Marangoni convection experiment in the FPEF examines fluid tension flow in micro-G.
2011-10-11
ISS029-E-025108 (11 Oct. 2011) --- NASA astronaut Mike Fossum, Expedition 29 commander, works on the Fluids Integrated Rack/Fluids and Combustion Facility (FIR/FCF), conducting another session with the Preliminary Advanced Colloids Experiment (PACE). Fossum is working at the Light Microscopy Module (LMM) in the Destiny laboratory of the International Space Station.
Relation between boundary slip mechanisms and waterlike fluid behavior.
Ternes, Patricia; Salcedo, Evy; Barbosa, Marcia C
2018-03-01
The slip of a fluid layer in contact with a solid confining surface is investigated for different temperatures and densities using molecular dynamic simulations. We show that for an anomalous waterlike fluid the slip goes as follows: for low levels of shear, defect slip appears and is related to the particle exchange between the fluid layers; at high levels of shear, global slip occurs and is related to the homogeneous distribution of the fluid in the confining surfaces. The oscillations in the transition velocity from defect to global slip are shown to be associated with changes in the layering distribution in the anomalous fluid.
NASA Astrophysics Data System (ADS)
Salahuddin, T.; Khan, Imad; Malik, M. Y.; Khan, Mair; Hussain, Arif; Awais, Muhammad
2017-05-01
The present work examines the internal resistance between fluid particles of tangent hyperbolic fluid flow due to a non-linear stretching sheet with heat generation. Using similarity transformations, the governing system of partial differential equations is transformed into a coupled non-linear ordinary differential system with variable coefficients. Unlike the current analytical works on the flow problems in the literature, the main concern here is to numerically work out and find the solution by using Runge-Kutta-Fehlberg coefficients improved by Cash and Karp (Naseer et al., Alexandria Eng. J. 53, 747 (2014)). To determine the relevant physical features of numerous mechanisms acting on the deliberated problem, it is sufficient to have the velocity profile and temperature field and also the drag force and heat transfer rate all as given in the current paper.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ernst, Timothy C.; Zigan, James A.
A waste heat recovery system includes a Rankine cycle (RC) circuit having a pump, a boiler, an energy converter, and a condenser fluidly coupled via conduits in that order, to provide additional work. The additional work is fed to an input of a gearbox assembly including a capacity for oil by mechanically coupling to the energy converter to a gear assembly. An interface is positioned between the RC circuit and the gearbox assembly to partially restrict movement of oil present in the gear assembly into the RC circuit and partially restrict movement of working fluid present in the RC circuitmore » into the gear assembly. An oil return line is fluidly connected to at least one of the conduits fluidly coupling the RC components to one another and is operable to return to the gear assembly oil that has moved across the interface from the gear assembly to the RC circuit.« less
NASA Astrophysics Data System (ADS)
Wu, Haiqing; Bai, Bing; Li, Xiaochun
2018-02-01
Existing analytical or approximate solutions that are appropriate for describing the migration mechanics of CO2 and the evolution of fluid pressure in reservoirs do not consider the high compressibility of CO2, which reduces their calculation accuracy and application value. Therefore, this work first derives a new governing equation that represents the movement of complex fluids in reservoirs, based on the equation of continuity and the generalized Darcy's law. A more rigorous definition of the coefficient of compressibility of fluid is then presented, and a power function model (PFM) that characterizes the relationship between the physical properties of CO2 and the pressure is derived. Meanwhile, to avoid the difficulty of determining the saturation of fluids, a method that directly assumes the average relative permeability of each fluid phase in different fluid domains is proposed, based on the theory of gradual change. An advanced analytical solution is obtained that includes both the partial miscibility and the compressibility of CO2 and brine in evaluating the evolution of fluid pressure by integrating within different regions. Finally, two typical sample analyses are used to verify the reliability, improved nature and universality of this new analytical solution. Based on the physical characteristics and the results calculated for the examples, this work elaborates the concept and basis of partitioning for use in further work.
NASA Astrophysics Data System (ADS)
Ridha, Syahrir; Ibrahim, Arif; Shahari, Radzi; Fonna, Syarizal
2018-05-01
The main objective of this work is to evaluate the effectiveness of graphene nanoplatelets (GNP) as filtration control materials in water based drilling fluids. Three (3) general samples of water based drilling fluids were prepared including basic potassium chloride (KCl) drilling fluids, nanosilica (NS) drilling fluids and GNP drilling fluids. Several concentrations of NS and GNP were dispersed in controlled formulations of water based drilling fluids. Standard API filtration tests were carried out for comparison purposes as well as High Temperature High Pressure (HTHP) filtration tests at 150 °F (∼66 °C), 250 °F (∼121 °C) and 350 °F (∼177 °C) at a fixed 500 (∼3.45MPa) psi to study the filtration trend as a function of temperature. Mud cake samples from several tests were selectively chosen and analyzed under Field Emission Scanning Electron Microscope (FESEM) for its morphology. Results from this work show that nanoparticle concentrations play a factor in filtration ability of colloid materials in water based drilling fluids when studied at elevated temperature. Low temperature filtration, however, shows only small differences in volume in all the drilling fluid samples. 0.1 ppb concentrations of GNP reduced the fluid loss of 350 °F by 4.6 mL as compared to the similar concentration of NS drilling fluids.
NASA Astrophysics Data System (ADS)
Hamdi, Basma; Mabrouk, Mohamed Tahar; Kairouani, Lakdar; Kheiri, Abdelhamid
2017-06-01
Different configurations of organic Rankine cycle (ORC) systems are potential thermodynamic concepts for power generation from low grade heat. The aim of this work is to investigate and optimize the performances of the three main ORC systems configurations: basic ORC, ORC with internal heat exchange (IHE) and regenerative ORC. The evaluation for those configurations was performed using seven working fluids with typical different thermodynamic behaviours (R245fa, R601a, R600a, R227ea, R134a, R1234ze and R1234yf). The optimization has been performed using a genetic algorithm under a comprehensive set of operative parameters such as the fluid evaporating temperature, the fraction of flow rate or the pressure at the steam extracting point in the turbine. Results show that there is no general best ORC configuration for all those fluids. However, there is a suitable configuration for each fluid. Contribution to the topical issue "Materials for Energy harvesting, conversion and storage II (ICOME 2016)", edited by Jean-Michel Nunzi, Rachid Bennacer and Mohammed El Ganaoui
Experimental study of high-performance cooling system pipeline diameter and working fluid amount
NASA Astrophysics Data System (ADS)
Nemec, Patrik; Malcho, Milan; Hrabovsky, Peter; Papučík, Štefan
2016-03-01
This work deals with heat transfer resulting from the operation of power electronic components. Heat is removed from the mounting plate, which is the evaporator of the loop thermosyphon to the condenser and by natural convection is transferred to ambient. This work includes proposal of cooling device - loop thermosyphon, with its construct and follow optimization of cooling effect. Optimization proceeds by selecting the quantity of working fluid and selection of diameters vapour line and liquid line of loop thermosyphon.
Experimental study on the inlet fogging system using two-fluid nozzles
NASA Astrophysics Data System (ADS)
Suryan, Abhilash; Kim, Dong Sun; Kim, Heuy Dong
2010-04-01
Large-capacity compressors in industrial plants and the compressors in gas turbine engines consume a considerable amount of power. The compression work is a strong function of the ambient air temperature. This increase in compression work presents a significant problem to utilities, generators and power producers when electric demands are high during the hot months. In many petrochemical process industries and gas turbine engines, the increase in compression work curtails plant output, demanding more electric power to drive the system. One way to counter this problem is to directly cool the inlet air. Inlet fogging is a popular means of cooling the inlet air to air compressors. In the present study, experiments have been performed to investigate the suitability of two-fluid nozzle for inlet fogging. Compressed air is used as the driving working gas for two-fluid nozzle and water at ambient conditions is dragged into the high-speed air jet, thus enabling the entrained water to be atomized in a very short distance from the exit of the two-fluid nozzle. The air supply pressure is varied between 2.0 and 5.0 bar and the water flow rate entrained is measured. The flow visualization and temperature and relative humidity measurements are carried out to specify the fogging characteristics of the two-fluid nozzle.
Experimental results concerning centrifugal impeller excitations
NASA Technical Reports Server (NTRS)
Vance, J. M.; Landadio, F. J.
1980-01-01
The effect of working fluid on the dynamics of an impeller with radial vanes was investigated. The impeller was supported vertically from a very flexible quill shaft in order to produce a low critical speed, and to allow the fluid dynamic effects on the impeller to predominate. The shaft was supported from ball bearings, so that there was no possibility of oil whip from fluid film bearings as a destabilizing influence. The impeller was run both in the atmosphere, and submerged in working fluids contained in a cylindrical housing, open at the top. Variable speed was obtained with a dc gearmotor drive unit. The speed was measured with a proximity probe pulse tachometer and electronic digital counter.
Exhaust bypass flow control for exhaust heat recovery
Reynolds, Michael G.
2015-09-22
An exhaust system for an engine comprises an exhaust heat recovery apparatus configured to receive exhaust gas from the engine and comprises a first flow passage in fluid communication with the exhaust gas and a second flow passage in fluid communication with the exhaust gas. A heat exchanger/energy recovery unit is disposed in the second flow passage and has a working fluid circulating therethrough for exchange of heat from the exhaust gas to the working fluid. A control valve is disposed downstream of the first and the second flow passages in a low temperature region of the exhaust heat recovery apparatus to direct exhaust gas through the first flow passage or the second flow passage.
Alternate working fluids for solar air conditioning applications
NASA Technical Reports Server (NTRS)
Evans, R. D.; Beck, J. K.
1978-01-01
An experimental investigation of sixteen different refrigerant-absorbent fluid pairs has been carried out in order to determine their suitability as the working fluid in a solar-powered absorption cycle air conditioner. The criteria used in the initial selection of a refrigerant-absorbent pair included: high affinity (large negative deviation from Raoult's Law), high solubility, low specific heat, low viscosity, stability, corrosive properties, safety, and cost. For practical solar considerations of a fluid pair, refrigerants were selected with low boiling points whereas absorbent fluids were selected with a boiling point considerably above that of the refrigerant. Additional restrictions are determined by the operating temperatures of the absorber and the generator; these temperatures were specified as 100 F (39 C) and 170 F (77 C). Data are presented for a few selected pressures at the specified absorber and generator temperatures.
Beroz, Justin Douglas; Hart, Anastasios John
2016-06-07
A pipette includes a movable piston and a diaphragm that at least partly defines a fluid chamber enclosing a volume of working fluid. The piston displaces a volumetric amount of the working fluid in the chamber when moved. In response, the diaphragm displaces a smaller volumetric amount of fluid outside the chamber. A deamplification ratio is defined by the ratio of the volume displaced by the diaphragm to the volume displaced by the piston. The deamplification ratio is adjustable by adjusting or changing the diaphragm and/or by adjusting the size of the fluid chamber. The deamplifying pipette enables measuring and dispensing of very small volumes of liquid and is easily adapted to commercially available pipette components. Pipette components such as a pipette tip or adaptor may include a diaphragm to enable deamplification of the nominal volume capacity of a given pipette device.
Fluid management systems technology summaries
NASA Technical Reports Server (NTRS)
Stark, J. A.; Blatt, M. H.; Bennett, F. O., Jr.; Campbell, B. J.
1974-01-01
A summarization and categorization of the pertinent literature associated with fluid management systems technology having potential application to in-orbit fluid transfer and/or associated storage are presented. A literature search was conducted to obtain pertinent documents for review. Reports determined to be of primary significance were summarized in the following manner: (1) report identification, (2) objective(s) of the work, (3) description of pertinent work performed, (4) major results, and (5) comments of the reviewer. Pertinent figures are presented on a single facing page separate from the text. Specific areas covered are: fluid line dynamics and thermodynamics, low-g mass gauging, other instrumentation, stratification/pressurization, low-g vent systems, fluid mixing refrigeration and reliquefaction, and low-g interface control and liquid acquisition systems. Reports which were reviewed and not summarized, along with reasons for not summarizing, are also listed.
Hall, Beverley; Wong, Diana; Healy, Clare; Tracy, Mark B; Tracy, Sally K; Rawlinson, William D
2017-04-01
Amniotic fluid lactate research is based on the hypothesis that a relationship exists between fatigued uterine muscles and raised concentrations of the metabolite lactate, which is excreted into the amniotic fluid during labor. To assess potentially confounding effects of lactate-producing organisms on amniotic fluid lactate measurements, we aimed to determine if the presence of vaginal Lactobacillus species was associated with elevated levels of amniotic fluid lactate, measured from the vaginal tract of women in labor. Results from this study contribute to a large prospective longitudinal study of amniotic fluid lactate at a teaching hospital in Sydney, Australia. Amniotic fluid lactate measurement was assessed at the time of routine vaginal examination, after membranes had ruptured, using a hand-held lactate meter StatStripXPress (Nova Biomedical). Vaginal swab samples were collected at the time of the first amniotic fluid lactate measurement and stored for later detection and quantification of Lactobacillus species using a TaqMan real-time PCR assay. Swab sample and amniotic fluid lactate results were paired and analyzed. The PCR assay detected Lactobacillus species in 48 of 388 (12%) vaginal swab specimens (8% positive, 4% low positive) collected from women in labor after membranes had ruptured. There was no significant difference in median and mean (respectively) amniotic fluid lactate levels with (8.35 mmol/L; 8.95 mmol/L) or without (8.5 mmol/L; 9.08 mmol/L) Lactobacillus species detected. There was no association between the presence or level of vaginal Lactobacillus species and the measurement of amniotic fluid lactate collected from the vaginal tract of women during labor. © 2017 Nordic Federation of Societies of Obstetrics and Gynecology.
Yamamoto, Syutaro; Tomoda, Hideyuki; Watanabe, Shoji
2007-01-01
Water-soluble metal working fluids are used for processing of aluminum alloy materials. This short article describes properties of new additives in water-soluble metal working fluids for aluminum alloy materials. Many half esters or diesters were prepared from the reactions of higher alcohols with acid anhydrides. Interestingly, diesters of PTMG (tetrahydrofuran oligomer, MW = 650 and 1000) and polybutylene oxide (MW = 650) with maleic anhydride and succinic anhydride showed both of an excellent anti-corrosion property for aluminum alloy and a good hard water tolerance. The industrial soluble type processing oils including these additives also showed anti-corrosion property and hard water tolerance.
Decreased levels of sRAGE in follicular fluid from patients with PCOS.
Wang, BiJun; Li, Jing; Yang, QingLing; Zhang, FuLi; Hao, MengMeng; Guo, YiHong
2017-03-01
This study aimed to explore the association between soluble receptor for advanced glycation end products (sRAGE) levels in follicular fluid and the number of oocytes retrieved and to evaluate the effect of sRAGE on vascular endothelial growth factor (VEGF) in granulosa cells in patients with polycystic ovarian syndrome (PCOS). Two sets of experiments were performed in this study. In part one, sRAGE and VEGF protein levels in follicular fluid samples from 39 patients with PCOS and 35 non-PCOS patients were measured by ELISA. In part two, ovarian granulosa cells were isolated from an additional 10 patients with PCOS and cultured. VEGF and SP1 mRNA and protein levels, as well as pAKT levels, were detected by real-time PCR and Western blotting after cultured cells were treated with different concentrations of sRAGE. Compared with the non-PCOS patients, patients with PCOS had lower sRAGE levels in follicular fluid. Multi-adjusted regression analysis showed that high sRAGE levels in follicular fluid predicted a lower Gn dose, more oocytes retrieved, and a better IVF outcome in the non-PCOS group. Logistic regression analysis showed that higher sRAGE levels predicted favorably IVF outcomes in the non-PCOS group. Multi-adjusted regression analysis also showed that high sRAGE levels in follicular fluid predicted a lower Gn dose in the PCOS group. Treating granulosa cells isolated from patients with PCOS with recombinant sRAGE decreased VEGF and SP1 mRNA and protein expression and pAKT levels in a dose-dependent manner. © 2017 Society for Reproduction and Fertility.
Teaching statics of fluids in bioengineering: a multidisciplinary proposal based on competences
NASA Astrophysics Data System (ADS)
Alborch, A.; Puzzella, A.; Lopez, N.; Cabrera, L.; Zabala, A.; Demartini, H.
2007-11-01
The aim of this work is to share the findings of an educational experience undertaken by first-year university students of bioengineering, oriented towards the model of Competence-based Education. Different aspects on integrative education pursued in the subject goals are explicitly focused here by designing a strategy within a contextualized and multidisciplinary approach that combines knowledge from Physics, Chemistry and Biology. The topic chosen for the work is Static of Fluids, because it allows relating pressure to its biological effects on human beings. After evaluating a pre-test, new interrelated strategies are implemented. Due to the motivation audiovisuals generate in adolescents, we start showing an argumentative film entitled 'The Big Blue', and continue with different individual and/or group activities, finishing with a post-test to assess the development of the competences proposed. Results are encouraging as regards the level of specific competences acquired and, complementarily, basic and professional competences in general. Besides, the experience met expectations as regards student motivation, interest and commitment to learning, which ensured the path taken by the academicians by means of implementing innovative strategies.
Evaluation of aerosolized medications during parabolic flight maneuvers
NASA Technical Reports Server (NTRS)
Lloyd, Charles W.; Martin, William J.; Gosbee, John
1991-01-01
The goal was to visually evaluate the effect gravity has on delivery of medications by the use of various aerosol devices. During parabolic flight the same four aerosols were retested as performed in studio ground tests. It appears that the Cetacaine spray and the Ventolin inhaler function without failure during all test. The pump spray (Nostril) appeared to function normally when the container was full, however it appeared to begin to fail to deliver a full mist with larger droplet size when the container was nearly empty. The simple hand spray bottle appeared to work when the container was full and performed progressively worse as the container was emptied. During Apollo flights, it was reported that standard spray bottles did not work well, however, they did not indicate why. It appears that we would also conclude that standard spray bottles do not function as well in zero gravity by failing to produce a normal mist spray. The standard spray bottle allowed the fluid to come out in a narrow fluid stream when held with the nozzle either level or slightly tilted upward.
An evaluation of Computational Fluid dynamics model for flood risk analysis
NASA Astrophysics Data System (ADS)
Di Francesco, Silvia; Biscarini, Chiara; Montesarchio, Valeria
2014-05-01
This work presents an analysis of the hydrological-hydraulic engineering requisites for Risk evaluation and efficient flood damage reduction plans. Most of the research efforts have been dedicated to the scientific and technical aspects of risk assessment, providing estimates of possible alternatives and of the risk associated. In the decision making process for mitigation plan, the contribute of scientist is crucial, due to the fact that Risk-Damage analysis is based on evaluation of flow field ,of Hydraulic Risk and on economical and societal considerations. The present paper will focus on the first part of process, the mathematical modelling of flood events which is the base for all further considerations. The evaluation of potential catastrophic damage consequent to a flood event and in particular to dam failure requires modelling of the flood with sufficient detail so to capture the spatial and temporal evolutions of the event, as well of the velocity field. Thus, the selection of an appropriate mathematical model to correctly simulate flood routing is an essential step. In this work we present the application of two 3D Computational fluid dynamics models to a synthetic and real case study in order to evaluate the correct evolution of flow field and the associated flood Risk . The first model is based on a opensource CFD platform called openFoam. Water flow is schematized with a classical continuum approach based on Navier-Stokes equation coupled with Volume of fluid (VOF) method to take in account the multiphase character of river bottom-water- air systems. The second model instead is based on the Lattice Boltzmann method, an innovative numerical fluid dynamics scheme based on Boltzmann's kinetic equation that represents the flow dynamics at the macroscopic level by incorporating a microscopic kinetic approach. Fluid is seen as composed by particles that can move and collide among them. Simulation results from both models are promising and congruent to experimental results available in literature, thought the LBM model requires less computational effort respect to the NS one.
An oral exam model for teaching advanced "Batchelor-level" fluid mechanics in the US
NASA Astrophysics Data System (ADS)
Freund, Jonathan
2016-11-01
A teaching model is developed to meet the challenge of teaching fluid mechanics at what might be considered a high level, at least by the current norms in the US. The initial goal was to avoid loss of concepts amidst the challenge of particular mathematical manipulations on particular assignments. However, it evolved toward fostering facile working knowledge of challenging material, such as in the books by Batchelor (e.g. streaming flow), Whitham (e.g. ship waves), and van Dyke (e.g. second-order boundary layer). To this end, the course model forgoes traditional assigned problems to focus on completion, augmentation, and in-depth understanding of the lecture material. The lectures are relatively traditional in structure, albeit with somewhat more interactive examples. The main unusual feature-again, by modern US standards-was assessment via multiple half-hour oral exams. This model has now been successful over 8 semesters for 3 different graduate courses in 2 departments. For all, students were assume to have already completed a full course at a "Navier-Stokes level". The presentation will include specifics of the course and exam structure, impressions of positive outcomes from the instructor, and a summary of the overwhelmingly positive student feedback.
The effect of lymphatic valve morphology on fluid transport
NASA Astrophysics Data System (ADS)
Alexeev, Alexander; Ballard, Matthew; Nepiyushchikh, Zhanna; Dixon, Brandon
2016-11-01
The lymphatic vasculature is present in nearly all invertebrate tissue, and is essential in the transport of fluid and particles such as immune cells, antigens, proteins and lipids from the tissue to lymph nodes and to the venous circulation. Lymphatic vessels are made of up a series of contractile units that work together in harmony as "micro hearts" to pump fluid against a pressure gradient. Lymphatic valves are critical to this functionality, as they open and close with the oscillating pressure gradients from contractions, thus allowing flow in only one direction and leading to a net pumping effect. We use a hybrid lattice-Boltzmann lattice spring model which captures fluid-solid interactions through two-way coupling between a viscous fluid and lymphatic valves in a section of a lymphatic vessel to study the dynamics of lymphatic valves and their effect on fluid transport. Further, we investigate the effect of variations in valve geometry and material properties on fluid pumping. This work helps to increase our understanding of the mechanisms of lymphatic fluid transport, which has implications in a variety of pathologies, including cancer metastasis, autoimmunity, atherosclerosis and obesity. Support from NSF CMMI 1635133 is gratefully acknowledged.
Corey, John A.
1984-05-29
A compressor, pump, or alternator apparatus is designed for use with a resonant free piston Stirling engine so as to isolate apparatus fluid from the periodically pressurized working fluid of the Stirling engine. The apparatus housing has a first side closed by a power coupling flexible diaphragm (the engine working member) and a second side closed by a flexible diaphragm gas spring. A reciprocally movable piston is disposed in a transverse cylinder in the housing and moves substantially at right angles relative to the flexible diaphragms. An incompressible fluid fills the housing which is divided into two separate chambers by suitable ports. One chamber provides fluid coupling between the power diaphragm of the RFPSE and the piston and the second chamber provides fluid coupling between the gas spring diaphragm and the opposite side of the piston. The working members of a gas compressor, pump, or alternator are driven by the piston. Sealing and wearing parts of the apparatus are mounted at the external ends of the transverse cylinder in a double acting arrangement for accessibility. An annular counterweight is mounted externally of the reciprocally movable piston and is driven by incompressible fluid coupling in a direction opposite to the piston so as to damp out transverse vibrations.
ERIC Educational Resources Information Center
Unsworth, Nash; Spillers, Gregory J.
2010-01-01
The current study examined the extent to which attention control abilities, secondary memory abilities, or both accounted for variation in working memory capacity (WMC) and its relation to fluid intelligence. Participants performed various attention control, secondary memory, WMC, and fluid intelligence measures. Confirmatory factor analyses…
Ishikawa, Naoyoshi; Miyata, Toshio; Ueda, Yasuhiko; Inagi, Reiko; Izuhara, Yuko; Yuzawa, Hiroko; Onogi, Hiroshi; Nishina, Makoto; Nangaku, Masaomi; Van Ypersele De Strihou, Charles; Kurokawa, Kiyoshi
2003-01-01
Reactive carbonyl compounds (RCOs) present in peritoneal dialysis (PD) fluid have been incriminated in the progressive deterioration of the peritoneal membrane in long-term PD patients. They are initially present in fresh conventional heat-sterilized glucose PD fluid and are supplemented during dwell time by the diffusion of blood RCOs within the peritoneal cavity. In the present study, RCO entrapping agents were immobilized on affinity beads to adsorb RCOs both in fresh PD fluid and in PD effluent. The RCO trapping potential of various compounds was assessed in vitro first by dissolving them in the tested fluid and subsequently after coupling with either epoxy- or amino-beads. The tested fluids include fresh heat-sterilized glucose and non-glucose PD fluids, and PD effluent. Their RCOs contents, that is, glyoxal (GO), methylglyoxal (MGO), 3-deoxyglucosone (3-DG), formaldehyde, 5-hydroxymethylfuraldehyde, acetaldehyde, and 2-furaldehyde were monitored by reverse-phase high-pressure liquid chromatography. The biocompatibility of PD fluid was assessed by a cytotoxic assay with either human epidermoid cell line A431 cells or with primary cultured human peritoneal mesothelial cells. Among the tested RCO entrapping agents, hydrazine coupled to epoxy-beads proved the most efficient. It lowered the concentrations of three dicarbonyl compounds (GO, MGO, and 3-DG) and those of aldehydes present in fresh heat-sterilized glucose PD fluid toward the low levels observed in filter-sterilized glucose PD fluid. It did not change the glucose and electrolytes concentration of the PD fluid but raised its pH from 5.2 to 5.9. Hydrazine-coupled epoxy-bead also lowered the PD effluent content of total RCOs, measured by the 2,4-dinitrophenylhydrazone (DNPH) method. The cytotoxicity of heat-sterilized PD fluid incubated with hydrazine-coupled epoxy-beads was decreased to the level observed in filter-sterilized PD fluid as the result of the raised pH and the lowered RCOs levels. Hydrazine-coupled epoxy-beads reduce the levels of a variety of dicarbonyls and aldehydes present in heat-sterilized glucose PD fluid to those in filter-sterilized PD fluid, without altering glucose, lactate, and electrolytes contents but with a rise in pH. Incubated with PD effluents, it is equally effective in reducing the levels of serum-derived RCOs. RCO entrapping agents immobilized on affinity beads improve in vitro the biocompatibility of conventional heat-sterilized glucose PD fluid. Their clinical applicability requires further studies.
Experimental Verification of an Instrument to Test Flooring Materials
NASA Astrophysics Data System (ADS)
Philip, Rony; Löfgren, Hans, Dr
2018-02-01
The focus of this work is to validate the fluid model with different flooring materials and the measurements of an instrument to test flooring materials and its force attenuating capabilities using mathematical models to describe the signature and coefficients of the floor. The main contribution of the present work focus on the development of a mathematical fluid model for floors. The aim of the thesis was to analyze, compare different floor materials and to study the linear dynamics of falling impacts on floors. The impact of the hammer during a fall is captured by an accelerometer and response is collected using a picoscope. The collected data was analyzed using matlab least square method which is coded as per the fluid model. The finding from this thesis showed that the fluid model works with more elastic model but it doesn’t work for rigid materials like wood. The importance of parameters like velocity, mass, energy loss and other coefficients of floor which influences the model during the impact of falling on floors were identified and a standardized testing method was set.
Beryllium chemical speciation in elemental human biological fluids.
Sutton, Mark; Burastero, Stephen R
2003-09-01
The understanding of beryllium chemistry in human body fluids is important for understanding the prevention and treatment of chronic beryllium disease. Thermodynamic modeling has traditionally been used to study environmental contaminant migration and rarely in the examination of metal (particularly beryllium) toxicology. In this work, a chemical thermodynamic speciation code (MINTEQA2) has been used to model and understand the chemistry of beryllium in simulated human biological fluids such as intracellular, interstitial, and plasma fluids, a number of airway surface fluids for patients with lung conditions, saliva, sweat, urine, bile, gastric juice, and pancreatic fluid. The results show that predicted beryllium solubility and speciation vary markedly between each simulated biological fluid. Formation of beryllium hydroxide and/or phosphate was observed in most of the modeled fluids, and results support the postulation that beryllium absorption in the gastrointestinal tract may be limited by the formation of beryllium phosphate solids. It is also postulated that beryllium is potentially 13% less soluble in the airway surface fluid of a patient with asthma when compared to a "normal" case. The results of this work, supported by experimental validation, can aid in the understanding of beryllium toxicology. Our results can potentially be applied to assessing the feasibility of biological monitoring or chelation treatment of beryllium body burden.
Alkaline phosphatase in osteoblasts is down-regulated by pulsatile fluid flow
NASA Technical Reports Server (NTRS)
Hillsley, M. V.; Frangos, J. A.
1997-01-01
It is our hypothesis that interstitial fluid flow plays a role in the bone remodeling response to mechanical loading. The fluid flow-induced expression of three proteins (collagen, osteopontin, and alkaline phosphatase) involved in bone remodeling was investigated. Rat calvarial osteoblasts subjected to pulsatile fluid flow at an average shear stress of 5 dyne/cm2 showed decreased alkaline phosphatase (AP) mRNA expression after only 1 hour of flow. After 3 hours of flow, AP mRNA levels had decreased to 30% of stationary control levels and remained at this level for an additional 5 hours of flow. Steady flow (4 dyne/cm2 fluid shear stress), in contrast, resulted in a delayed and less dramatic decrease in AP mRNA expression to 63% of control levels after 8 hours of flow. The reduced AP mRNA expression under pulsatile flow conditions was followed by reduced AP enzyme activity after 24 hours. No changes in collagen or osteopontin mRNA expression were detected over 8 hours of pulsatile flow. This is the first time fluid flow has been shown to affect gene expression in osteoblasts.
Kuipers during replacement of the Marangoni Surface Fluid Dynamics Experiment
2012-03-15
ISS030-E-142827 (15 March 2012) --- European Space Agency astronaut Andre Kuipers, Expedition 30 flight engineer, works to remove the Marangoni Surface fluid physics experiment from the Fluid Physics Experiment Facility (FPEF) in the Kibo laboratory of the International Space Station.
Sarkar, N; Basu, A
2012-11-01
We construct a coarse-grained effective two-dimensional (2d hydrodynamic theory as a theoretical model for a coupled system of a fluid membrane and a thin layer of a polar active fluid in its ordered state that is anchored to the membrane. We show that such a system is prone to generic instabilities through the interplay of nonequilibrium drive, polar order and membrane fluctuation. We use our model equations to calculate diffusion coefficients of an inclusion in the membrane and show that their values depend strongly on the system size, in contrast to their equilibrium values. Our work extends the work of S. Sankararaman and S. Ramaswamy (Phys. Rev. Lett., 102, 118107 (2009)) to a coupled system of a fluid membrane and an ordered active fluid layer. Our model is broadly inspired by and should be useful as a starting point for theoretical descriptions of the coupled dynamics of a cell membrane and a cortical actin layer anchored to it.
Chang, K C; Chan, M C; Leung, W M; Kong, F Y; Mak, C M; Chen, S Pl; Yu, W C
2018-02-01
Pleural fluid adenosine deaminase level can be applied to rapidly detect tuberculous pleural effusion. We aimed to establish a local diagnostic cut-off value for pleural fluid adenosine deaminase to identify patients with tuberculous pleural effusion, and optimise its utility. We retrospectively reviewed the medical records of consecutive adults with pleural fluid adenosine deaminase level measured by the Diazyme commercial kit (Diazyme Laboratories, San Diego [CA], United States) during 1 January to 31 December 2011 in a cluster of public hospitals in Hong Kong. We considered its level alongside early (within 2 weeks) findings in pleural fluid and pleural biopsy, with and without applying Light's criteria in multiple scenarios. For each scenario, we used the receiver operating characteristic curve to identify a diagnostic cut-off value for pleural fluid adenosine deaminase, and estimated its positive and negative predictive values. A total of 860 medical records were reviewed. Pleural effusion was caused by congestive heart failure, chronic renal failure, or hypoalbuminaemia caused by liver or kidney diseases in 246 (28.6%) patients, malignancy in 198 (23.0%), non-tuberculous infection in 168 (19.5%), tuberculous pleural effusion in 157 (18.3%), and miscellaneous causes in 91 (10.6%). All those with tuberculous pleural effusion had a pleural fluid adenosine deaminase level of ≤100 U/L. When analysis was restricted to 689 patients with pleural fluid adenosine deaminase level of ≤100 U/L and early negative findings for malignancy and non-tuberculous infection in pleural fluid, the positive predictive value was significantly increased and the negative predictive value non-significantly reduced. Using this approach, neither additionally restricting analysis to exudates by Light's criteria nor adding closed pleural biopsy would further enhance predictive values. As such, the diagnostic cut-off value for pleural fluid adenosine deaminase is 26.5 U/L, with a sensitivity of 87.3%, specificity of 93.2%, positive predictive value of 79.2%, negative predictive value of 96.1%, and accuracy of 91.9%. Sex, age, and co-morbidity did not significantly affect prediction of tuberculous pleural effusion using the cut-off value. We have established a diagnostic cut-off level for pleural fluid adenosine deaminase in the diagnosis of tuberculous pleural effusion by restricting analysis to a level of ≤100 U/L, and considering early pleural fluid findings for malignancy and non-tuberculous infection, but not Light's criteria.
Production Level CFD Code Acceleration for Hybrid Many-Core Architectures
NASA Technical Reports Server (NTRS)
Duffy, Austen C.; Hammond, Dana P.; Nielsen, Eric J.
2012-01-01
In this work, a novel graphics processing unit (GPU) distributed sharing model for hybrid many-core architectures is introduced and employed in the acceleration of a production-level computational fluid dynamics (CFD) code. The latest generation graphics hardware allows multiple processor cores to simultaneously share a single GPU through concurrent kernel execution. This feature has allowed the NASA FUN3D code to be accelerated in parallel with up to four processor cores sharing a single GPU. For codes to scale and fully use resources on these and the next generation machines, codes will need to employ some type of GPU sharing model, as presented in this work. Findings include the effects of GPU sharing on overall performance. A discussion of the inherent challenges that parallel unstructured CFD codes face in accelerator-based computing environments is included, with considerations for future generation architectures. This work was completed by the author in August 2010, and reflects the analysis and results of the time.
Numerical analysis on the action of centrifuge force in magnetic fluid rotating shaft seals
NASA Astrophysics Data System (ADS)
Zou, Jibin; Li, Xuehui; Lu, Yongping; Hu, Jianhui
2002-11-01
The magnetic fluid seal is suitable for high-speed rotating shaft seal applications. Centrifuge force will have evident influence on magnetic fluid rotating shaft seals. The seal capacity of the rotating shaft seal can be improved or increased by some measures. Through hydrodynamic analysis the moving status of the magnetic fluid is worked out. By numerical method, the magnetic field and the isobars in the magnetic fluid of a seal device are computed. Then the influence of the centrifuge force on the magnetic fluid seal is calculated quantitatively.
Plasma volume, osmolality, vasopressin, and renin activity during graded exercise in man
NASA Technical Reports Server (NTRS)
Convertino, V. A.; Keil, L. C.; Bernauer, E. M.; Greenleaf, J. E.
1981-01-01
The influence of work intensity on plasma volume, osmolality, vasopressin and renin activity and the interrelationships between these responses are investigated. Plasma volume, renin activity and osmotic, sodium and arginine vasopressin concentrations were measured in venous blood samples taken from 15 healthy male subjects before and after six minutes of bicycle ergometer exercise at 100, 175 and 225 W. Plasma volume is found to decrease significantly with increasing work intensity, while increases in Na(+) concentration, osmolality and vasopressin are only observed to be significant when the work intensity exceeds 40% maximal aerobic capacity and plasma resin activity increased linearly at all work levels. In addition, significant correlations are observed between plasma volume and osmolality and sodium changes, and between vasopressin and osmolality and sodium content changes. Data thus support the hypotheses that (1) vasopressin may be the primary controlling endocrine for fluid and electrolyte levels following exercise; (2) an exercise intensity greater than 40% maximal aerobic capacity is required to stimulate vasopressin release through changes in plasma osmolality; and (3) the stimulation of the renin-angiotensin system is a more general stress response.
Airborne asbestos exposures associated with work on asbestos fire sleeve materials.
Blake, Charles L; Harbison, Stephen C; Johnson, Giffe T; Harbison, Raymond D
2011-11-01
Asbestos-containing fire sleeves have been used as a fire protection measure for aircraft fluid hoses. This investigation was conducted to determine the level of airborne asbestos fiber exposure experienced by mechanics who work with fire sleeve protected hoses. Duplicate testing was performed inside a small, enclosed workroom during the fabrication of hose assemblies. Personal air samples taken during this work showed detectable, but low airborne asbestos fiber exposures. Analysis of personal samples (n=9) using phrase contract microscopy (PCM) indicated task duration airborne fiber concentrations ranging from 0.017 to 0.063 fibers per milliliter (f/ml) for sampling durations of 167-198 min, and 0.022-0.14 f/ml for 30 min samples. Airborne chrysotile fibers were detected for four of these nine personal samples, and the resulting asbestos adjusted airborne fiber concentrations ranged from 0.014 to 0.025 f/ml. These results indicate that work with asbestos fire sleeve and fire sleeve protected hose assemblies, does not produce regulatory noncompliant levels of asbestos exposure for persons who handle, cut and fit these asbestos-containing materials. Copyright © 2011 Elsevier Inc. All rights reserved.
In vitro pleural fluid clottability and fibrinogen content.
Glauser, F L; Otis, P T; Levine, R I; Smith, W R
1975-08-01
Twenty-three specimens of pleural fluid from 23 patients were examined for quantitative fibrinogen, total protein levels, and for clottability in vitro using the recalcification time. Of the 19 specimens of pleural fluid from patients without loculation, 11 (seven exudates) had no detectable fibrinogen; another 8 (six exudates) had a mean fibrinogen level of 55.0 +/- 10.2 mg percent, and a mean recalcification time of 19.4 +/- 2.6 minutes. The pleural fluids from the four patients with loculation had no detectable fibrinogen. The only fluids containing fibrinolytic activity were from the nonloculated non-fibrinogen-containing group. No correlation existed between pleural fluid/plasma total protein ratios and pleural fluid/plasma fibrinogen ratios. In vitro clottability in this study did not reflect the in vivo tendency for coagulation and loculation.
NASA Technical Reports Server (NTRS)
Schallhorn, Paul; Majumdar, Alok
2012-01-01
This paper describes a finite volume based numerical algorithm that allows multi-dimensional computation of fluid flow within a system level network flow analysis. There are several thermo-fluid engineering problems where higher fidelity solutions are needed that are not within the capacity of system level codes. The proposed algorithm will allow NASA's Generalized Fluid System Simulation Program (GFSSP) to perform multi-dimensional flow calculation within the framework of GFSSP s typical system level flow network consisting of fluid nodes and branches. The paper presents several classical two-dimensional fluid dynamics problems that have been solved by GFSSP's multi-dimensional flow solver. The numerical solutions are compared with the analytical and benchmark solution of Poiseulle, Couette and flow in a driven cavity.
Multiphase numerical analysis of heat pipe with different working fluids for solar applications
NASA Astrophysics Data System (ADS)
Aswath, S.; Netaji Naidu, V. H.; Padmanathan, P.; Raja Sekhar, Y.
2017-11-01
Energy crisis is a prognosis predicted in many cases with the indiscriminate encroachment of conventional energy sources for applications on a massive scale. This prediction, further emboldened by the marked surge in global average temperatures, attributed to climate change and global warming, the necessity to conserve the environment and explore alternate sources of energy is at an all-time high. Despite being among the lead candidates for such sources, solar energy is utilized far from its vast potential possibilities due to predominant economic constraints. Even while there is a growing need for solar panels at more affordable rates, the other options to harness better out of sun’s energy is to optimize and improvise existing technology. One such technology is the heat pipe used in Evacuated Tube Collectors (ETC). The applications of heat pipe have been gaining momentum in various fields since its inception and substantial volumes of research have explored optimizing and improving the technology which is proving effective in heat recovery and heat transfer better than conventional systems. This paper carries out a computational analysis on a comparative simulation between two working fluids within heat pipe of same geometry. It further endeavors to study the multiphase transitions within the heat pipe. The work is carried out using ANSYS Fluent with inputs taken from solar data for the location of Vellore, Tamil Nadu. A wickless, gravity-assisted heat pipe (GAHP) is taken for the simulation. Water and ammonia are used as the working fluids for comparative multiphase analysis to arrive at the difference in heat transfer at the condenser section. It is demonstrated that a heat pipe ETC with ammonia as working fluid showed higher heat exchange (temperature difference) as against that of water as working fluid. The multiphase model taken aided in study of phase transitions within both cases and supported the result of ammonia as fluid being a better candidate.
NASA Astrophysics Data System (ADS)
Ding, M.; Hjelm, R.; Sussman, A. J.
2016-12-01
Low-permeability geomedia are prevalent in subsurface environments. They have become increasingly important in a wide range of applications such as CO2-sequestration, hydrocarbon recovery, enhanced geothermal systems, legacy waste stewardship, high-level radioactive waste disposal, and global security. The flow and transport characteristics of low-permeability geomedia are dictated by their exceedingly low permeability values ranging from 10-6 to 10-12 darcy with porosities dominated by nanoscale pores. Developing new characterization methods and robust computational models that allow estimation of transport properties of low-permeability geomedia has been identified as a critical basic research and technology development need for controlling subsurface and fluids flow. Due to its sensibility to hydrogen and flexible sample environment, neutron based elastic and inelastic scattering can, through various techniques, interrogate all the nanoscale pores in the sample whether they are fluid accessible or not, and readily characterize interfacial waters. In this presentation, we will present two studies revealing the effects of nanoscale pore confinement on fluid dynamics in geomedia. In one study, we use combined (ultra-small)/small-angle elastic neutron scatterings to probe nanoporous features responses in geological materials to transport processes. In the other study, incoherent inelastic neutron scattering was used to distingwish between intergranular pore water and fluid inclusion moisture in bedded rock salt, and to explore their thermal stablibility. Our work demonstrates that neutron based elastic and inelastic scatterings are techniques of choice for in situ probing hydrocarbon and water behavior in nanoporous materials, providing new insights into water-rock interaction and fluids transport in low-permeability geomaterials.
NASA Astrophysics Data System (ADS)
De Vita, F.; de Tullio, M. D.; Verzicco, R.
2016-04-01
This work focuses on the comparison between Newtonian and non-Newtonian blood flows through a bileaflet mechanical heart valve in the aortic root. The blood, in fact, is a concentrated suspension of cells, mainly red blood cells, in a Newtonian matrix, the plasma, and consequently its overall behavior is that of a non-Newtonian fluid owing to the action of the cells' membrane on the fluid part. The common practice, however, assumes the blood in large vessels as a Newtonian fluid since the shear rate is generally high and the effective viscosity becomes independent of the former. In this paper, we show that this is not always the case even in the aorta, the largest artery of the systemic circulation, owing to the pulsatile and transitional nature of the flow. Unexpectedly, for most of the pulsating cycle and in a large part of the fluid volume, the shear rate is smaller than the threshold level for the blood to display a constant effective viscosity and its shear thinning character might affect the system dynamics. A direct inspection of the various flow features has shown that the valve dynamics, the transvalvular pressure drop and the large-scale features of the flow are very similar for the Newtonian and non-Newtonian fluid models. On the other hand, the mechanical damage of the red blood cells (hemolysis), induced by the altered stress values in the flow, is larger for the non-Newtonian fluid model than for the Newtonian one.
Adrenal hormones in human follicular fluid.
Jimena, P; Castilla, J A; Peran, F; Ramirez, J P; Vergara, F; Molina, R; Vergara, F; Herruzo, A
1992-11-01
Considerable evidence indicates that adrenal hormones may affect gonadal function. To assess the role of some adrenal hormones in human follicular fluid and their relationship with the ability of the oocyte to be fertilized and then to cleave in vitro, cortisol and dehydroepiandrosterone sulfate were measured in follicular fluid obtained at the time of oocyte recovery for in vitro fertilization from cycles stimulated by clomiphene citrate, human menopausal gonadotropin and human chorionic gonadotropin. Thirty-six follicular fluid containing mature oocyte-corona-cumulus complexes and free of visible blood contamination were included in this study. There was no significant difference in follicular fluid dehydroepiandrosterone sulfate concentration between follicles with oocytes which did or did not fertilize (5.1 +/- 1.1 vs 5.8 +/- 2.0 mumol/l). However, follicular fluid from follicles whose oocytes were not fertilized had levels of cortisol significantly higher than those in follicular fluid from follicles containing successfully fertilized oocytes (406.0 +/- 75.9 vs 339.2 +/- 37.0 nmol/l; p < 0.005). No significant correlations were found between rates of embryo cleavage and cortisol and dehydroepiandrosterone levels in follicular fluid. We conclude that cortisol levels in follicular fluid may provide an index of fertilization outcome, at least in stimulated cycles by clomiphene citrate, human menopausal gonadotropin and human chorionic gonadotropin.
NASA Astrophysics Data System (ADS)
Wang, Youliang; Wu, Yongbo; Guo, Huiru; Fujimoto, Masakazu; Nomura, Mitsuyoshi; Shimada, Kunio
2015-05-01
In nano-precision surface finishing of engineering materials using MCF (magnetic compound fluid) slurry, the water-based MCF slurry is preferable from the viewpoint of the environmental issue and the running cost of cleaning workpiece and equipment. However, the uncoated-CIPs (carbonyl-iron-powders) within the conventional MCF slurry have low ability against aqueous corrosion, leading to the performance deterioration and working life shortening of the conventional MCF slurry. This study proposed a new MCF slurry containing ZrO2-coated CIPs instead of the uncoated CIPs. Its performance in the polishing of oxygen-free copper was compared experimentally with that of the conventional one. The results showed that the work-surface finish polished with the new slurry was in the same level as that with the conventional one when the slurry was used soon after prepared, i.e., the settling time was 0 min; however, as the settling time increased the uncoated-CIPs got rusty, leading to a deterioration in the slurry performance. By contrast, no rust was observed on ZrO2-coated CIPs even the settling time reached several days, indicating the employment of ZrO2-coated CIPs prolonged the working-life of the MCF slurry greatly.
The human otitis media with effusion: a numerical-based study.
Areias, B; Parente, M P L; Santos, C; Gentil, F; Natal Jorge, R M
2017-07-01
Otitis media is a group of inflammatory diseases of the middle ear. Acute otitis media and otitis media with effusion (OME) are its two main types of manifestation. Otitis media is common in children and can result in structural alterations in the middle ear which will lead to hearing losses. This work studies the effects of an OME on the sound transmission from the external auditory meatus to the inner ear. The finite element method was applied on the present biomechanical study. The numerical model used in this work was built based on the geometrical information obtained from The visible ear project. The present work explains the mechanisms by which the presence of fluid in the middle ear affects hearing by calculating the magnitude, phase and reduction of the normalized umbo velocity and also the magnitude and phase of the normalized stapes velocity. A sound pressure level of 90 dB SPL was applied at the tympanic membrane. The harmonic analysis was performed with the auditory frequency varying from 100 Hz to 10 kHz. A decrease in the response of the normalized umbo and stapes velocity as the tympanic cavity was filled with fluid was obtained. The decrease was more accentuated at the umbo.
The complexity of oral physiology and its impact on salivary diagnostics.
Helmerhorst, E J; Dawes, C; Oppenheim, F G
2018-04-01
Saliva contains biomarkers for systemic as well as oral diseases. This study was undertaken to assess the variability in the sources of such biomarkers (plasma, cells) and attempted to identify saliva deterioration markers in order to improve saliva diagnostic outcomes. Inter- and intrasubject variations in salivary gingival crevicular fluid levels were determined by measuring salivary albumin and transferrin levels. The purity of collected glandular secretions was determined by bacterial culture, and the variability in epithelial cell numbers by cell counting and optical density measurement. Saliva sample deterioration markers were identified by RP-HPLC and LC-ESI-MS/MS. Tenfold variations were observed in plasma-derived albumin and transferrin levels, emphasizing the need for biomarker normalization with respect to plasma contributions to saliva. Epithelial cell levels varied 50-fold in samples collected before and after a meal. Salivary fungal levels varied within subjects and among subjects from 0 to >1,000 colony-forming units per milliliter. In saliva samples incubated for various time intervals at 37°C, five peptides were identified that steadily increased in intensity over time and which could be explored as "deterioration markers." Taking saliva characteristics appropriately into account will help realize the promise that this body fluid is suitable to be exploited for reliable healthcare monitoring and surveillance. Published 2017. This article is a U.S. Government work and is in the public domain in the USA.
FSS (Fluid Servicer System) from the Kibo module to the ESA COL
2009-07-08
ISS020-E-017933 (8 July 2009) --- Japan Aerospace Exploration Agency (JAXA) astronaut Koichi Wakata, Expedition 20 flight engineer, works with the Fluid Servicing System (FSS) and the Fluid Control Pump Assembly (FCPA) in the Columbus laboratory of the International Space Station.
Superhot fluids circulating close to magma intrusions: a contribution from analogue modelling
NASA Astrophysics Data System (ADS)
Montanari, Domenico; Agostini, Andrea; Bonini, Marco; Corti, Giacomo
2017-04-01
Magma overpressure at the time of the emplacement at shallow crustal levels may lead to deformation (i.e. forced folding, fracturing and faulting) in the country rock, both at local and regional scale. To get insights into this process, we reproduced and analysed in the laboratory the fracture/fault network associated with the emplacement of magma at shallow crustal levels. We used a mixture of quartz sand and K-feldspar fine sand as an analogue for the brittle crust, and polyglycerols for the magma. The models were able to reproduce complex 3D architectures of deformation resulting from magma emplacement, with different deformation patterns -invariably dominated by forced folding and associated brittle faulting/fracturing- resulting from variable parameters. These results provide useful hints into geothermal researches. Fractures and faults associated with magma emplacement are indeed expected to significantly influence the distribution and migration of superhot geothermal fluids near the edge of the magma intrusion. These structures can therefore be considered as potential targets for geothermal or mineral deposits exploration. In this perspective, the results of analogue models may provide useful geometric and conceptual constraints for field work, numerical modeling, and particularly seismic interpretation for achieving a better understanding and tuning of the integrated conceptual model concerning the circulation of supercritical fluids. The research leading to these results has received funding from the European Community's Seventh Framework Programme under grant agreement No. 608553 (Project IMAGE).
Fluid Structure Interaction Techniques For Extrusion And Mixing Processes
NASA Astrophysics Data System (ADS)
Valette, Rudy; Vergnes, Bruno; Coupez, Thierry
2007-05-01
This work focuses on the development of numerical techniques devoted to the simulation of mixing processes of complex fluids such as twin-screw extrusion or batch mixing. In mixing process simulation, the absence of symmetry of the moving boundaries (the screws or the rotors) implies that their rigid body motion has to be taken into account by using a special treatment We therefore use a mesh immersion technique (MIT), which consists in using a P1+/P1-based (MINI-element) mixed finite element method for solving the velocity-pressure problem and then solving the problem in the whole barrel cavity by imposing a rigid motion (rotation) to nodes found located inside the so called immersed domain, each sub-domain (screw, rotor) being represented by a surface CAD mesh (or its mathematical equation in simple cases). The independent meshes are immersed into a unique background computational mesh by computing the distance function to their boundaries. Intersections of meshes are accounted for, allowing to compute a fill factor usable as for the VOF methodology. This technique, combined with the use of parallel computing, allows to compute the time-dependent flow of generalized Newtonian fluids including yield stress fluids in a complex system such as a twin screw extruder, including moving free surfaces, which are treated by a "level set" and Hamilton-Jacobi method.
NASA Astrophysics Data System (ADS)
Cattes, Stefanie M.; Gubbins, Keith E.; Schoen, Martin
2016-05-01
In this work, we employ classical density functional theory (DFT) to investigate for the first time equilibrium properties of a Heisenberg fluid confined to nanoscopic slit pores of variable width. Within DFT pair correlations are treated at modified mean-field level. We consider three types of walls: hard ones, where the fluid-wall potential becomes infinite upon molecular contact but vanishes otherwise, and hard walls with superimposed short-range attraction with and without explicit orientation dependence. To model the distance dependence of the attractions, we employ a Yukawa potential. The orientation dependence is realized through anchoring of molecules at the substrates, i.e., an energetic discrimination of specific molecular orientations. If the walls are hard or attractive without specific anchoring, the results are "quasi-bulk"-like in that they can be linked to a confinement-induced reduction of the bulk mean field. In these cases, the precise nature of the walls is completely irrelevant at coexistence. Only for specific anchoring nontrivial features arise, because then the fluid-wall interaction potential affects the orientation distribution function in a nontrivial way and thus appears explicitly in the Euler-Lagrange equations to be solved for minima of the grand potential of coexisting phases.
The enhancement of friction ridge detail on brass ammunition casings using cold patination fluid.
James, Richard Michael; Altamimi, Mohamad Jamal
2015-12-01
Brass ammunition is commonly found at firearms related crime scenes. For this reason, many studies have focused on evidence that can be obtained from brass ammunition such as DNA, gunshot residue and fingerprints. Latent fingerprints on ammunition can provide good forensic evidence, however; fingerprint development on ammunition casings has proven to be difficult. A method using cold patination fluid is described as a potential tool to enhance friction ridge detail on brass ammunition casings. Current latent fingerprint development methods for brass ammunition have either failed to provide the necessary quality of friction ridge detail or can be very time consuming and require expensive equipment. In this study, the enhancement of fingerprints on live ammunition has been achieved with a good level of detail whilst the development on spent casings has to an extent also been possible. Development with cold patination fluid has proven to be a quick, simple and cost-effective method for fingerprint development on brass ammunition that can be easily implemented for routine police work. Crown Copyright © 2015. Published by Elsevier Ireland Ltd. All rights reserved.
Age-related decline in cognitive control: the role of fluid intelligence and processing speed
2014-01-01
Background Research on cognitive control suggests an age-related decline in proactive control abilities whereas reactive control seems to remain intact. However, the reason of the differential age effect on cognitive control efficiency is still unclear. This study investigated the potential influence of fluid intelligence and processing speed on the selective age-related decline in proactive control. Eighty young and 80 healthy older adults were included in this study. The participants were submitted to a working memory recognition paradigm, assessing proactive and reactive cognitive control by manipulating the interference level across items. Results Repeated measures ANOVAs and hierarchical linear regressions indicated that the ability to appropriately use cognitive control processes during aging seems to be at least partially affected by the amount of available cognitive resources (assessed by fluid intelligence and processing speed abilities). Conclusions This study highlights the potential role of cognitive resources on the selective age-related decline in proactive control, suggesting the importance of a more exhaustive approach considering the confounding variables during cognitive control assessment. PMID:24401034
Numerical Simulations for Turbulent Drag Reduction Using Liquid Infused Surfaces
NASA Astrophysics Data System (ADS)
Arenas-Navarro, Isnardo
Numerical simulations of the turbulent flow over Super Hydrophobic and Liquid Infused Surfaces have been performed in this work. Three different textured surfaces have been considered: longitudinal square bars, transversal square bars and staggered cubes. The numerical code combines an immersed boundary method to mimic the substrate and a level set method to track the interface. Liquid Infused Surfaces reduce the drag by locking a lubricant within structured roughness to facilitate a slip velocity at the surface interface. The conceptual idea is similar to Super Hydrophobic Surfaces, which rely on a lubricant air layer, whereas liquid-infused surfaces use a preferentially wetting liquid lubricant to create a fluid-fluid interface. This slipping interface has been shown to be an effective method of passively reducing skin friction drag in turbulent flows. Details are given on the effect of the viscosity ratio between the two fluids and the dynamics of the interface on drag reduction. An attempt has been made to reconcile Super-Hydrophobic, Liquid Infused and rough wall under the same framework by correlating the drag to the wall normal velocity fluctuations.
Elasticity-Driven Backflow of Fluid-Driven Cracks
NASA Astrophysics Data System (ADS)
Lai, Ching-Yao; Dressaire, Emilie; Ramon, Guy; Huppert, Herbert; Stone, Howard A.
2016-11-01
Fluid-driven cracks are generated by the injection of pressurized fluid into an elastic medium. Once the injection pressure is released, the crack closes up due to elasticity and the fluid in the crack drains out of the crack through an outlet, which we refer to as backflow. We experimentally study the effects of crack size, elasticity of the matrix, and fluid viscosity on the backflow dynamics. During backflow, the volume of liquid remaining in the crack as a function of time exhibits a transition from a fast decay at early times to a power law behavior at late times. Our results at late times can be explained by scaling arguments balancing elastic and viscous stresses in the crack. This work may relate to the environmental issue of flowback in hydraulic fracturing. This work is supported by National Science Foundation via Grant CBET-1509347 and partially supported by Andlinger Center for Energy and the Environment at Princeton University.
Passon, S; Uthoff, S; Jäckle-Meyer, I
1998-01-01
Improvement of clinical outcome of dialysis therapy is a task for everybody working in a dialysis unit. Here we consider dialysis conditions such as choice of treatment parameters and composition of dialysis fluid which may influence clinical outcome of dialysis therapy. Providing 'adequate' dialysis is the aim of the daily work of a dialysis nurse. Haemodialysis parameters with potential impact on dialysis adequacy are discussed with respect to quantification and optimisation. Every year, each patient comes in contact with 20,000 I dialysis fluid during HD treatment. The composition of the fluid, its physical and microbiological quality and their impact on clinical outcome are considered. The function of PD fluid is different from that of an HD fluid thus additional aspects have to be considered regarding its composition. Information is given how the composition and biocompatibility of PD solutions impact the dialysis therapy and how individual patient needs are considered.
Öngöz Dede, F; Bozkurt Doğan, Ş; Balli, U; Avci, B; Durmuşlar, M C; Baratzade, T
2016-12-01
The purpose of this study was to investigate the effects of obesity on reduced and oxidized glutathione (GSH and GSSG) levels in the gingival crevicular fluid, plasma and saliva of patients with chronic periodontitis and to evaluate the changes after nonsurgical periodontal therapy. The study included 60 patients: 30 patients with chronic periodontitis (15 obese patients and 15 normal weight patients) and 30 healthy control subjects (15 obese patients and 15 normal weight patients). Gingival crevicular fluid, plasma and saliva samples were collected, and clinical periodontal measurements were recorded at baseline and at the first month after periodontal therapy from patients with chronic periodontitis. GSH and GSSG levels were analyzed with spectrophotometry. The GSH levels in the plasma, saliva and gingival crevicular fluid in obese individuals with chronic periodontitis were lower than in normal weight individuals at baseline (p < 0.01). There was a significant difference in the GSH/GSSG ratio in plasma and gingival crevicular fluid between the obese and normal weight groups at baseline (p < 0.01). The GSH levels in plasma, gingival crevicular fluid and saliva were significantly increased in both chronic periodontitis groups after nonsurgical periodontal therapy (p < 0.01). A significant positive correlation was found between GSH levels in saliva, plasma and gingival crevicular fluid in all groups (p < 0.001). The study revealed that obesity in patients with chronic periodontitis is associated with decreased GSH levels and the GSH/GSSG ratio. Moreover, nonsurgical periodontal therapy may be helpful for improvement in glutathione values in obese and normal weight individuals with chronic periodontitis. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
[Improving myocardial mechanics parameters of severe burn rabbits with oral fluid resuscitation].
Ruan, Jing; Zhang, Bing-qian; Wang, Guang; Luo, Zhong-hua; Zheng, Qing-yi; Zheng, Jian-sheng; Huang, Yue-sheng; Xiao, Rong
2008-08-01
To investigate the protective effect of oral fluid resuscitation on cardiac function in severe burn rabbits. One hundred and fifty rabbits were randomly divided into normal control group (NC group, n = 6, without treatment), burn group (B group, n = 42, without fluid therapy), immediate oral fluid resuscitation group (C group, n = 42), delayed oral fluid resuscitation group (D group, n = 30) and delayed and rapid oral fluid resuscitation group (E group, n = 30). The rabbits in B, C, D, E groups were subjected to 40% TBSA full-thickness burn, then were treated with fluid therapy immediately after burn (C group), at 6 hour after burn (D, E groups). The myocardial mechanics parameters including mean arterial pressure (MAP), left ventricular systolic pressure (LVSP), left ventricular end diastolic pressure (LVEDP), LV +/- dp/dt max were observed at 2, 6, 8, 12, 24, 36 and 48 post burn hour (PBH). Urine output was also examined. The level of LVSP, LV +/- dp/dt max in B roup were significantly lower than those in NC group. The level of LVSP, LV +/- dp/dt max in the C and E group were singnificantly increased during 24 hour after burn. The level of LV + dp/dt max and LV-dp/dt max in C group peaked at 8 PBH (892 +/- 116 kPa/s) and at 6PBH (724 +/- 149 kPa/s) respectively. The levels of LV +/- dp/dt max, LVSP in D group at each time point were similar to B group (P > 0.05). Both the levels of LV +/- dp/dt max in E group peaked at 8 PBH. The level of LVEDP was no obvious difference between B and other groups at each time point (P > 0.05). The changes of MAP and urine output on 24 PBH in each group were similar to above indices. Effective oral fluid therapy in severe burn rabbits during 24 hours after burn can ameliorate myocardial mechanics parameters. The amount of fluid resuscitation can be estimated according to relevant formula for delayed fluid resuscitation in burn rabbits.
Lawlor-Savage, Linette; Goghari, Vina M.
2016-01-01
Enhancing cognitive ability is an attractive concept, particularly for middle-aged adults interested in maintaining cognitive functioning and preventing age-related declines. Computerized working memory training has been investigated as a safe method of cognitive enhancement in younger and older adults, although few studies have considered the potential impact of working memory training on middle-aged adults. This study investigated dual n-back working memory training in healthy adults aged 30–60. Fifty-seven adults completed measures of working memory, processing speed, and fluid intelligence before and after a 5-week web-based dual n-back or active control (processing speed) training program. Results: Repeated measures multivariate analysis of variance failed to identify improvements across the three cognitive composites, working memory, processing speed, and fluid intelligence, after training. Follow-up Bayesian analyses supported null findings for training effects for each individual composite. Findings suggest that dual n-back working memory training may not benefit working memory or fluid intelligence in healthy adults. Further investigation is necessary to clarify if other forms of working memory training may be beneficial, and what factors impact training-related benefits, should they occur, in this population. PMID:27043141
Development of an integrated BEM approach for hot fluid structure interaction
NASA Technical Reports Server (NTRS)
Dargush, Gary F.; Banerjee, Prasanta K.; Honkala, Keith A.
1988-01-01
In the present work, the boundary element method (BEM) is chosen as the basic analysis tool, principally because the definition of temperature, flux, displacement and traction are very precise on a boundary-based discretization scheme. One fundamental difficulty is, of course, that a BEM formulation requires a considerable amount of analytical work, which is not needed in the other numerical methods. Progress made toward the development of a boundary element formulation for the study of hot fluid-structure interaction in Earth-to-Orbit engine hot section components is reported. The primary thrust of the program to date has been directed quite naturally toward the examination of fluid flow, since boundary element methods for fluids are at a much less developed state.
Effects of Parental Education Level on Fluid Intelligence of Philippine Public School Students
ERIC Educational Resources Information Center
Vista, Alvin D.; Grantham, Tarek C.
2010-01-01
This study examines the effect of parental education levels (PELs) on the fluid intelligence of Filipino public school students. The data were drawn from a normative study of a nonverbal intelligence test involving more than 2,700 students sampled across the country. As expected, PELs have a significant impact on fluid intelligence as measured…
Shaparin, Naum; Mehta, Neel; Kunkel, Frank; Stripp, Richard; Borg, Damon; Kolb, Elizabeth
2017-11-01
Interpretation limitations of urine drug testing and the invasiveness of blood toxicology have motivated the desire for the development of simpler methods to assess biologically active drug levels on an individualized patient basis. Oral fluid is a matrix well-suited for the challenge because collections are based on simple noninvasive procedures and drug concentrations better correlate to blood drug levels as oral fluid is a filtrate of the blood. Well-established pharmacokinetic models were utilized to generate oral fluid steady state concentration ranges to assess the interpretive value of the alternative matrix to monitor steady state plasma oxycodone levels. Paired oral fluid and plasma samples were collected from patients chronically prescribed oxycodone and quantitatively analyzed by liquid chromatography tandem mass spectrometry. Steady state plasma concentration ranges were calculated for each donor and converted to an equivalent range in oral fluid. Measured plasma and oral fluid oxycodone concentrations were compared with respective matrix-matched steady state ranges, using each plasma steady state classification as the control. A high degree of correlation was observed between matrices when classifying donors according to expected steady state oxycodone concentration. Agreement between plasma and oral fluid steady state classifications was observed in 75.6% of paired samples. This study supports novel application of basic pharmacokinetic knowledge to the pain management industry, simplifying and improving individualized drug monitoring and risk assessment through the use of oral fluid drug testing. Many benefits of established therapeutic drug monitoring in plasma can be realized in oral fluid for patients chronically prescribed oxycodone at steady state. © 2017 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com
Viumdal, Håkon; Mylvaganam, Saba
2017-01-01
In oil and gas and geothermal installations, open channels followed by sieves for removal of drill cuttings, are used to monitor the quality and quantity of the drilling fluids. Drilling fluid flow rate is difficult to measure due to the varying flow conditions (e.g., wavy, turbulent and irregular) and the presence of drilling cuttings and gas bubbles. Inclusion of a Venturi section in the open channel and an array of ultrasonic level sensors above it at locations in the vicinity of and above the Venturi constriction gives the varying levels of the drilling fluid in the channel. The time series of the levels from this array of ultrasonic level sensors are used to estimate the drilling fluid flow rate, which is compared with Coriolis meter measurements. Fuzzy logic, neural networks and support vector regression algorithms applied to the data from temporal and spatial ultrasonic level measurements of the drilling fluid in the open channel give estimates of its flow rate with sufficient reliability, repeatability and uncertainty, providing a novel soft sensing of an important process variable. Simulations, cross-validations and experimental results show that feedforward neural networks with the Bayesian regularization learning algorithm provide the best flow rate estimates. Finally, the benefits of using this soft sensing technique combined with Venturi constriction in open channels are discussed. PMID:29072595
A fictitious domain approach for the Stokes problem based on the extended finite element method
NASA Astrophysics Data System (ADS)
Court, Sébastien; Fournié, Michel; Lozinski, Alexei
2014-01-01
In the present work, we propose to extend to the Stokes problem a fictitious domain approach inspired by eXtended Finite Element Method and studied for Poisson problem in [Renard]. The method allows computations in domains whose boundaries do not match. A mixed finite element method is used for fluid flow. The interface between the fluid and the structure is localized by a level-set function. Dirichlet boundary conditions are taken into account using Lagrange multiplier. A stabilization term is introduced to improve the approximation of the normal trace of the Cauchy stress tensor at the interface and avoid the inf-sup condition between the spaces for velocity and the Lagrange multiplier. Convergence analysis is given and several numerical tests are performed to illustrate the capabilities of the method.
Fluid Mechanics of a High Performance Racing Bicycle Wheel
NASA Astrophysics Data System (ADS)
Mercat, Jean-Pierre; Cretoux, Brieuc; Huat, Francois-Xavier; Nordey, Benoit; Renaud, Maxime; Noca, Flavio
2013-11-01
In 2012, MAVIC released the most aerodynamic bicycle wheel on the market, the CXR 80. The french company MAVIC has been a world leader for many decades in the manufacturing of bicycle wheels for competitive events such as the Olympic Games and the Tour de France. Since 2010, MAVIC has been in a research partnership with the University of Applied Sciences in Geneva, Switzerland, for the aerodynamic development of bicycle wheels. While most of the development up to date has been performed in a classical wind tunnel, recent work has been conducted in an unusual setting, a hydrodynamic towing tank, in order to achieve low levels of turbulence and facilitate quantitative flow visualization (PIV). After a short introduction on the aerodynamics of bicycle wheels, preliminary fluid mechanics results based on this novel setup will be presented.
Performance analysis of automobile radiator using carboxyl graphene nanofluids
NASA Astrophysics Data System (ADS)
Rao Ponangi, Babu; Sumanth, S.; Krishna, V.; Seetharam, T. R.; Seetharamu, K. N.
2018-04-01
A feasible solution to increase the effectiveness of the radiator will be the use of stabilized nanofluid. A mixture of small amount of solid particle, whose size is less than 100nm in the fluid phase, is termed as nanofluid. In current work, a small concentration of carboxyl-graphene nanostructure sheets/flakes are used as the solid medium, where conventional Ethylene glycol is used as the fluid medium. Visible checking method has been adopted, to check the stability of the nanofluid. The results showed the promising level of improvement in the values of Nusselt number and Effectiveness of the radiator, without changing the actual design of radiator. Examination of Pressure drop shows, a very small increase in its value even though the nanofluid has been used. About 19% improvement in the value of Effectiveness has been achieved at very small concentrations.
Simonelli, Angela; Guadagni, Rossella; De Franciscis, Pasquale; Colacurci, Nicola; Pieri, Maria; Basilicata, Pascale; Pedata, Paola; Lamberti, Monica; Sannolo, Nicola; Miraglia, Nadia
2017-01-01
The study aimed to give a first data set of bisphenol A (BPA) levels in the peritoneal fluid of patients suffering from endometriosis and to investigate the relationship between BPA exposure and endometriosis. A questionnaire investigating the occupational context, life environment, and habits was administered to 68 patients suffering from endometriosis and 60 endometriosis-free subjects (control group). Urine and peritoneal fluids samples were collected and analysed by GC/MSMS for BPA dosage. Some of the investigated environmental/lifestyle risk factors (closeness to industries/activities at risk) were associated with an increase in endometriosis; smoking resulted as protective factor; others (use of food plastic boxes) did not seem to influence the onset of pathology. The association between the occupational exposure summarising all examined risk factors (working activity, personal protective equipment, seniority) and endometriosis was statistically significant (χ 2 = 5.252, p = 0.02). Contrasting results were obtained when specific activities were examined. Detectable urinary BPA levels were found in all analysed samples (patients: 1.17-12.68 pg/µl; mean ± SD, 5.31 ± 3.36 pg/µl; control group: 1.28-2.35 pg/µl; mean ± SD, 1.64 ± 0.49 pg/µl; median; 1.46 pg/µl), with a statistically significant difference between patients and controls, showing an association between BPA exposure and endometriosis. Only a few subjects from the control group supplied peritoneal fluid; hence, no comparison test with patients (range 0.39-1.46 pg/µl; mean ± SD, 0.67 ± 0.30 pg/µl; median, 0.58 pg/µl) was carried out. Results highlight the potential association between BPA exposure and endometriosis, as well as the current lack of knowledge regarding occupational exposure to BPA and the need of epidemiological studies focused on single activities/occupations, such as housewives, cleaners, students.
Kawanishi, Hideki; Akiba, Takashi; Masakane, Ikuto; Tomo, Tadashi; Mineshima, Michio; Kawasaki, Tadayuki; Hirakata, Hideki; Akizawa, Tadao
2009-04-01
The Committee of Scientific Academy of the Japanese Society for Dialysis Therapy (JSDT) proposes a new standard on microbiological management of fluids for hemodialysis and related therapies. This standard is within the scope of the International Organization for Standardization (ISO), which is currently under revision. This standard is to be applied to the central dialysis fluid delivery systems (CDDS), which are widely used in Japan. In this standard, microbiological qualities for dialysis water and dialysis fluids are clearly defined by endotoxin level and bacterial count. The qualities of dialysis fluids were classified into three levels: standard, ultrapure, and online prepared substitution fluid. In addition, the therapeutic application of each dialysis fluid is clarified. Since high-performance dialyzers are frequently used in Japan, the standard recommends that ultrapure dialysis fluid be used for all dialysis modalities at all dialysis facilities. It also recommends that the dialysis equipment safety management committee at each facility should validate the microbiological qualities of online prepared substitution fluid.
Deirmengian, Carl; Kardos, Keith; Kilmartin, Patrick; Cameron, Alexander; Schiller, Kevin; Parvizi, Javad
2014-09-03
The diagnosis of periprosthetic joint infection remains a challenge. The purpose of this study was to evaluate the combined measurement of the levels of two synovial fluid biomarkers, α-defensin and C-reactive protein (CRP), for the diagnosis of periprosthetic joint infection. One hundred and forty-nine synovial fluid aspirates, including 112 from patients with an aseptic diagnosis and thirty-seven from patients with periprosthetic joint infection, met the inclusion criteria for this prospective study. Synovial fluid aspirates were tested for α-defensin and CRP levels with use of enzyme-linked immunosorbent assay (ELISA). The Musculoskeletal Infection Society (MSIS) definition of periprosthetic joint infection was utilized for the classification of cases as aseptic or infected. Comorbidities, such as inflammatory conditions, that could confound a test for periprosthetic joint infection were documented, but the patients with such comorbidities were included in the study. The combination of synovial fluid α-defensin and CRP tests demonstrated a sensitivity of 97% and a specificity of 100% for the diagnosis of periprosthetic joint infection. Synovial fluid α-defensin tests alone demonstrated a sensitivity of 97% and a specificity of 96% for the diagnosis of periprosthetic joint infection. Synovial fluid CRP tests, with a low threshold of 3 mg/L, reversed all-false positive α-defensin results without affecting the sensitivity of the test. The diagnostic characteristics of these assays were achieved in a population of patients demonstrating a 23% rate of systemic inflammatory diseases (in the series as a whole) and a 27% rate of concurrent antibiotic treatment (in the infection group). The synovial fluid levels of α-defensin in the setting of periprosthetic joint infection were unchanged during concurrent antibiotic treatment. The combined measurement of synovial fluid α-defensin and CRP levels correctly diagnosed 99% of the cases in this study as aseptic or infected. This was achieved despite the inclusion of patients with systemic inflammatory disease and those receiving treatment with antibiotics. Diagnostic Level II. See Instructions for Authors for a complete description of levels of evidence. Copyright © 2014 by The Journal of Bone and Joint Surgery, Incorporated.
Langley Symposium on Aerodynamics, volume 1
NASA Technical Reports Server (NTRS)
Stack, Sharon H. (Compiler)
1986-01-01
The purpose of this work was to present current work and results of the Langley Aeronautics Directorate covering the areas of computational fluid dynamics, viscous flows, airfoil aerodynamics, propulsion integration, test techniques, and low-speed, high-speed, and transonic aerodynamics. The following sessions are included in this volume: theoretical aerodynamics, test techniques, fluid physics, and viscous drag reduction.
Cavitation-based hydro-fracturing simulator
Wang, Jy-An John; Wang, Hong; Ren, Fei; Cox, Thomas S.
2016-11-22
An apparatus 300 for simulating a pulsed pressure induced cavitation technique (PPCT) from a pressurized working fluid (F) provides laboratory research and development for enhanced geothermal systems (EGS), oil, and gas wells. A pump 304 is configured to deliver a pressurized working fluid (F) to a control valve 306, which produces a pulsed pressure wave in a test chamber 308. The pulsed pressure wave parameters are defined by the pump 304 pressure and control valve 306 cycle rate. When a working fluid (F) and a rock specimen 312 are included in the apparatus, the pulsed pressure wave causes cavitation to occur at the surface of the specimen 312, thus initiating an extensive network of fracturing surfaces and micro fissures, which are examined by researchers.
Walter, Carl E.; Van Konynenburg, Richard; VanSant, James H.
1992-01-01
An isotopic heat source is formed using stacks of thin individual layers of a refractory isotopic fuel, preferably thulium oxide, alternating with layers of a low atomic weight diluent, preferably graphite. The graphite serves several functions: to act as a moderator during neutron irradiation, to minimize bremsstrahlung radiation, and to facilitate heat transfer. The fuel stacks are inserted into a heat block, which is encased in a sealed, insulated and shielded structural container. Heat pipes are inserted in the heat block and contain a working fluid. The heat pipe working fluid transfers heat from the heat block to a heat exchanger for power conversion. Single phase gas pressure controls the flow of the working fluid for maximum heat exchange and to provide passive cooling.
Frank, Jeffrey I.; Rosengart, Axel J.; Kasza, Ken; Yu, Wenhua; Chien, Tai-Hsin; Franklin, Jeff
2006-10-10
Apparatuses, systems, methods, and computer code for, among other things, monitoring the health of samples such as the brain while providing local cooling or heating. A representative device is a heat transfer probe, which includes an inner channel, a tip, a concentric outer channel, a first temperature sensor, and a second temperature sensor. The inner channel is configured to transport working fluid from an inner inlet to an inner outlet. The tip is configured to receive at least a portion of the working fluid from the inner outlet. The concentric outer channel is configured to transport the working fluid from the inner outlet to an outer outlet. The first temperature sensor is coupled to the tip, and the second temperature sensor spaced apart from the first temperature sensor.
Carballo, J; Mota, N; Barreto, G; Colmenero, F J
1995-01-01
A little-studied procedure for adjusting the properties of low-fat products is to use the influence that both composition and certain processing factors exert on these properties. The object of the present work was to assess the effects of protein level (P, ranging from 10% to 16%), fat level (F, ranging from 10.1% to 22%) and cooking temperature (HT, ranging from 77 °C to 105 °C) on the binding properties and colour of meat emulsions. Protein content was the variable that most influenced total expressible fluid (TEF) and purge loss. Heating rate had scarcely any effect on the binding properties of Bologna sausages. Analysis of variance indicated that the regression models for parameters L, a and b were not significant.
The Status of Fluid Mechanics in Bioengineering Curricula.
ERIC Educational Resources Information Center
Miller, Gerald E.; Hyman, William A.
1981-01-01
Describes the status of fluid mechanics courses in bioengineering curricula. A survey of institutions offering bioengineering degrees indicates that over half do not require fluid mechanics courses. Suggests increasing number of mechanics courses to increase the quality of bioengineering students and to prepare students for graduate work and more…
Raines, Jenni; Snow, Rodney; Nichols, David; Aisbett, Brad
2015-06-01
(i) To evaluate firefighters' pre- and post-shift hydration status across two shifts of wildfire suppression work in hot weather conditions. (ii) To document firefighters' fluid intake during and between two shifts of wildfire suppression work. (iii) To compare firefighters' heart rate, activity, rating of perceived exertion (RPE), and core temperature across the two consecutive shifts of wildfire suppression work. Across two consecutive days, 12 salaried firefighters' hydration status was measured immediately pre- and post-shift. Hydration status was also measured 2h post-shift. RPE was also measured immediately post-shift on each day. Work activity, heart rate, and core temperature were logged continuously during each shift. Ten firefighters also manually recorded their food and fluid intake before, during, and after both fireground shifts. Firefighters were not euhydrated at all measurement points on Day one (292±1 mOsm l(-1)) and euhydrated across these same time points on Day two (289±0.5 mOsm l(-1)). Fluid consumption following firefighters' shift on Day one (1792±1134ml) trended (P = 0.08) higher than Day two (1108±1142ml). Daily total fluid intake was not different (P = 0.27), averaging 6443±1941ml across both days. Core temperature and the time spent ≥ 70%HRmax were both elevated on Day one (when firefighters were not euhydrated). Firefighters' work activity profile was not different between both days of work. There was no difference in firefighters' pre- to post-shift hydration within each shift, suggesting ad libitum drinking was at least sufficient to maintain pre-shift hydration status, even in hot conditions. Firefighters' relative hypohydration on Day one (despite a slightly lower ambient temperature) may have been associated with elevations in core temperature, more time in the higher heart rate zones, and 'post-shift' RPE. © The Author 2015. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.
[Synovial fluid from aseptically failed total hip or knee arthroplasty is not toxic to osteoblasts].
Gallo, J; Zdařilová, A; Rajnochová Svobodová, A; Ulrichová, J; Radová, L; Smižanský, M
2010-10-01
A failure of total hip or knee artroplasty is associated with an increased production of joint fluid. This contains wear particles and host cells and proteins, and is assumed to be involved in the pathogenesis of aseptic loosening and periprosthetic osteolysis. This study investigated the effect of synovial fluid from patients with aseptically failed joint prostheses on osteoblast cultures. Synovial fluid samples were obtained from patients with failed total joint prostheses (TJP; n=36) and from control patient groups (n = 16) involving cases without TJP and osteoarthritis, without TJP but with osteoarthritis, and with stable TJP. The samples were treated in the standard manner and then cultured with the SaOS-2 cell line which shows the characteristics and behaviour of osteoblasts. Each fluid sample was also examined for the content of proteins, cells and selected cytokines (IL-1ß, TNF-α, IL-6, RANKL and OPG detected by ELISA). We tested the hypothesis assuming that the fluids from failed joints would show higher cytotoxicity to osteoblast culture and we also expected higher levels of IL-1ß, TNF-α, IL-6, and RANKL in patients with TJP failure and/ or with more severe bone loss. The statistical methods used included the Kruskal-Wallis ANOVA and Mann-Whitney U test. The fluids from failed TJPs showed the highest RANKL and the lowest OPG levels resulting in the highest RANKL/OPG ratio. However, there was no evidence suggesting that the joint fluids from failed TJPs would be more toxic to osteoblast culture than the fluids from control groups. In addition, no correlation was found between the fluid levels of molecules promoting inflammation and osteoclastic activity and the extent of bone loss in the hip (in terms of Saleh's classification) or the knee (AORI classification). In fact, the fluids from failed TJPs had higher protein levels in comparison with the controls, but the difference was not significant. The finding of high RANKL levels and low OPG concentrations is in agreement with the theory of aseptic loosening and periprosthetic osteolysis. The other cytokines, particularly TNF-α and IL-1ß, were found in low levels. This can be explained by the stage of particle disease at which the samples were taken for ELISA analysis. It is probable that the level of signal molecules reflects osteolytic process activity and is therefore not constant. The reason for no correlation found between cytokine levels and the extent of bone loss may also lie in the use of therapeutic classifications of bone defects that is apparently less sensitive to the biological activity of aseptic loosening and/or periprosthetic osteolysis. Synovial fluids from failed total hip or knee joint prostheses are not toxic to osteoblast cultures. Cytotoxicity indicators and levels of pro-inflammatory and pro-osteoclastic cytokines (IL-1ß, TNF-α, IL-6, RANKL and OPG) do not correlate well with the extent of periprosthetic bone loss. Key words: total joint replacement, arthroplasty, aseptic loosening, periprosthetic osteolysis, joint fluid, SaOS-2 cell line, cytotoxicity, cytokines, RANKL, OPG.
Abedin, Rubaiyet; Heidarian, Sharareh; Flake, John C; Hung, Francisco R
2017-10-24
We used computational tools to evaluate three working fluid mixtures for single-effect absorption refrigeration systems, where the generator (desorber) is powered by waste or solar heat. The mixtures studied here resulted from combining a widely used hydrofluorocarbon (HFC) refrigerant, R134a, with three common deep eutectic solvents (DESs) formed by mixing choline chloride (hydrogen bond acceptor, HBA) with urea, glycerol, or ethylene glycol as the hydrogen bond donor (HBD) species. The COSMOtherm/TmoleX software package was used in combination with refrigerant data from NIST/REFPROP, to perform a thermodynamic evaluation of absorption refrigeration cycles using the proposed working fluid mixtures. Afterward, classical MD simulations of the three mixtures were performed to gain insight on these systems at the molecular level. Larger cycle efficiencies are obtained when R134a is combined with choline chloride and ethylene glycol, followed by the system where glycerol is the HBD, and finally that where the HBD is urea. MD simulations indicate that the local density profiles of all species exhibit very sharp variations in systems containing glycerol or urea; furthermore, the Henry's law constants of R134a in these two systems are larger than those observed for the HFC in choline chloride and ethylene glycol, indicating that R134a is more soluble in the latter DES. Interaction energies indicate that the R134a-R134a interactions are weaker in the system where ethylene glycol is the HBD, as compared to in the other DES. Radial distribution functions confirm that in all systems, the DES species do not form strong directional interactions (e.g., hydrogen bonds) with the R134a molecules. Relatively strong interactions are observed between the Cl anions and the hydrogen atoms in R134a; however, the atom-atom interactions between R134a and the cation and HBD species are weaker and do not play a significant role in the solvation of the refrigerant. In all systems, R134a has the largest diffusion coefficients, followed by the HBD, the anion and the cation; the diffusion coefficients are the largest in the systems containing ethylene glycol, followed by those having glycerol and urea. This work is our first step toward our long-term goal of designing and demonstrating optimal working fluid mixtures for use in absorption refrigeration systems. Our results suggest that COSMO-RS can be used to perform a rapid screening of a large number of working fluid mixtures, and select a few candidates for further exploration using molecular simulations and experiments. These latter approaches can be used to refine the accuracy of the COSMO-RS predictions, and to optimize the selection of optimal working fluid mixtures for demonstration in absorption refrigeration systems powered by solar or waste heat sources.
The effect of periodontal treatment on C-reactive protein: A clinical study.
Kumar, Santosh; Shah, Samir; Budhiraja, Shilpa; Desai, Khushboo; Shah, Chirag; Mehta, Dhaval
2013-07-01
Chronic periodontitis in amultifactorial inflammatory disease which is caused by various microorganisms. Many studies have found close association between chronic periodontitis and C-reactive protein (CRP). CRPis an inflammatory marker which increases in all inflammatory condition. The present clinical study was designed to show the effect of periodontal treatment on the CRP levels of gingival crevicular fluid and to determine the effect of nonsurgical therapy in minimizing the CRP levels in chronic generalized periodontitis. Gingival crevicular fluid was collected using a micro capillary pipette that was hand calibrated at every 1 mm till 10 mm, from selected sites in the subjects on the 1st, 14th and 45th days. Decreased CRP levels of gingival crevicular fluid were observed at the end of the study. There was a 37% reduction in probing pocket depth and 45% gain in clinical attachment level and a reduction of about 57% after 14 days and 90% reduction of CRP levels in gingival crevicular fluid after 45 days. Thus, the results show that the presence of CRP level is more significant in gingival crevicular fluid and confirms the underlying inflammatory component of the disease activity in chronic periodontitis.
Changes in the interstitial fluid and the muscle water in rabbits in hemorrhagic shock.
Wolcott, M W; Malinin, T I; Wu, N M
1976-01-01
Dynamics and changes in the biochemical composition in the interstitial fluid and the muscle water were studied in hemorrhagic shock. The interstitial fluid was collected from implanted perforated capsules. Muscle biopsies were examined with regard to their water content by the steady state magnetic nuclear resonance spectroscopy. The consistent and what appears to be the most significant changes were the fall in the interstitial fluid pressures, the quantitative reduction of muscle water, a sharp fall in the blood and interstitial blood pH, the moderate hyperkalemia and lack of change in blood an interstitial fluid sodium, and the rise in blood glucose levels not accompanied by a rise in the interstitial fluid glucose levels. PMID:11754
Altinel, Levent; Saritas, Z Kadir; Kose, Kamil Cagri; Pamuk, Kamuran; Aksoy, Yusuf; Serteser, Mustafa
2007-02-01
Avocado and soya unsaponifiables (ASU) are plant extracts used as a slow-acting antiarthritic agent. ASU stimulate the synthesis of matrix components by chondrocytes, probably by increasing the production of transforming growth factor-beta (TGF-beta). TGF-beta is expressed by chondrocytes and osteoblasts and is present in cartilage matrix. This study investigates the effect of ASU treatment on the levels of two isoforms of TGFbeta, TGF-beta1 and TGF-beta2, in the knee joint fluid using a canine model. Twenty-four outbred dogs were divided into three groups. The control animals were given a normal diet, while the treated animals were given 300 mg ASU every three days or every day. Joint fluid samples were obtained prior to treatment, and at the end of every month (up to three months). TGF-beta1 and TGF-beta2 levels were measured using a quantitative sandwich enzyme immunoassay technique. ASU treatment caused an increase in TGF-beta1 and TGF-beta2 levels in the joint fluid when compared to controls. The different doses did not cause a significant difference in joint fluid TGF levels. TGF-beta1 levels in the treated animals reached maximum values at the end of the second month and then decreased after the third month, while TGF-beta2 levels showed a marginal increase during the first two months, followed by a marked increase at the end of the third month. In conclusion, ASU increased both TGF-beta1 and TGF-beta2 levels in knee joint fluid.
Comparing volume of fluid and level set methods for evaporating liquid-gas flows
NASA Astrophysics Data System (ADS)
Palmore, John; Desjardins, Olivier
2016-11-01
This presentation demonstrates three numerical strategies for simulating liquid-gas flows undergoing evaporation. The practical aim of this work is to choose a framework capable of simulating the combustion of liquid fuels in an internal combustion engine. Each framework is analyzed with respect to its accuracy and computational cost. All simulations are performed using a conservative, finite volume code for simulating reacting, multiphase flows under the low-Mach assumption. The strategies used in this study correspond to different methods for tracking the liquid-gas interface and handling the transport of the discontinuous momentum and vapor mass fractions fields. The first two strategies are based on conservative, geometric volume of fluid schemes using directionally split and un-split advection, respectively. The third strategy is the accurate conservative level set method. For all strategies, special attention is given to ensuring the consistency between the fluxes of mass, momentum, and vapor fractions. The study performs three-dimensional simulations of an isolated droplet of a single component fuel evaporating into air. Evaporation rates and vapor mass fractions are compared to analytical results.
Study of toluene stability for an Organic Rankine Cycle (ORC) space-based power system
NASA Technical Reports Server (NTRS)
Havens, Vance; Ragaller, Dana
1988-01-01
The design, fabrication, assembly, and endurance operation of a dynamic test loop, built to evaluate the thermal stability of a proposed Organic Rankine Cycle (ORC) working fluid, is discussed. The test fluid, toluene, was circulated through a heater, simulated turbine, regenerator, condenser and pump to duplicate an actual ORC system. The maximum nominal fluid temperature, 750 F, was at the turbine simulator inlet. Samples of noncondensible gases and liquid toluene were taken periodically during the test. The samples were analyzed to identify the degradation products formed and the quantity of these products. From these data it was possible to determine the degradation rate of the working fluid and the generation rate of noncondensible gases. A further goal of this work was to relate the degradation observed in the dynamic operating loop to degradation obtained in isothermal capsule tests. This relationship was the basis for estimating the power loop degradation in the Space Station Organic Rankine Cycle system.
30 CFR 250.614 - Well-control fluids, equipment, and operations.
Code of Federal Regulations, 2011 CFR
2011-07-01
... workover string, the annulus shall be filled with well-control fluid before the change in such fluid level... equivalent well-control fluid volume shall be calculated and posted near the operator's station. A mechanical... utilized: (1) A fill-up line above the uppermost BOP; (2) A well-control, fluid-volume measuring device for...
Neutron Scattering and Diffraction Studies of Fluids and Fluid-Solid Interactions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cole, David R; Herwig, Kenneth W; Mamontov, Eugene
2006-01-01
There can be no disputing the fact that neutron diffraction and scattering have made a clear contribution to our current understanding of the structural and dynamical characteristics of liquid water and water containing dissolved ions at ambient conditions and to a somewhat lesser degree other state conditions involving a change in temperature and pressure. Indeed, a molecular-level understanding of how fluids (e.g., water, CO{sub 2}, CH{sub 4}, higher hydrocarbons, etc.) interact with and participate in reactions with other solid earth materials are central to the development of predictive models that aim to quantify a wide array of geochemical processes. Inmore » the context of natural systems, interrogation of fluids and fluid-solid interactions at elevated temperatures and pressures is an area requiring much more work, particularly for complex solutions containing geochemically relevant cations, anions, and other important dissolved species such as CO{sub 2} or CH{sub 4}. We have tried to describe a series of prototypical interfacial and surface problems using neutron scattering to stimulate the thinking of earth scientists interested applying some of these approaches to confined systems of mineralogical importance. Our ability to predict the molecular-level properties of fluids and fluid-solid interactions relies heavily on the synergism between experiments such as neutron diffraction or inelastic neutron scattering and molecular-based simulations. Tremendous progress has been made in closing the gap between experimental observations and predicted behavior based on simulations due to improvements in the experimental methodologies and instrumentation on the one hand, and the development of new potential models of water and other simple and complex fluids on the other. For example there has been an emergence of studies taking advantage of advanced computing power that can accommodate the demands of ab initio molecular dynamics. On the neutron instrumentation side while much of the quasielastic work described has been performed using instrumentation located at reactor based sources, the advent of 2{sup nd} generation spallation neutron sources like ISIS, new generation sources like the SNS at the Oak Ridge National Laboratory and the low repetition rate 2{sup nd} target station at ISIS offer significant opportunities for the study of interfacial and entrained liquids. At the very least, an improvement of the counting statistics by one to two orders of magnitude on many instruments such as vibrational and time-of-flight spectrometers at SNS will allow parametric studies of many systems which otherwise would be prohibitively time consuming. The extended-Q SANS diffractometer at SNS will offer very high intensity and unparalleled Q-range to extend the accessible length scale in the real space, from 0. 05 nm to150 nm. The backscattering spectrometer will provide very high intensity and excellent energy resolution through unprecedented range of energy transfers, thereby allowing simultaneous studies of translational and rotational diffusion components in various systems. The vibrational spectrometer with two orders of magnitude improvement in performance and the capability to perform simultaneous structural measurements should present exciting opportunities to and engender an entire new population of users in the neutron community.« less
Application of wave mechanics theory to fluid dynamics problems: Fundamentals
NASA Technical Reports Server (NTRS)
Krzywoblocki, M. Z. V.
1974-01-01
The application of the basic formalistic elements of wave mechanics theory is discussed. The theory is used to describe the physical phenomena on the microscopic level, the fluid dynamics of gases and liquids, and the analysis of physical phenomena on the macroscopic (visually observable) level. The practical advantages of relating the two fields of wave mechanics and fluid mechanics through the use of the Schroedinger equation constitute the approach to this relationship. Some of the subjects include: (1) fundamental aspects of wave mechanics theory, (2) laminarity of flow, (3) velocity potential, (4) disturbances in fluids, (5) introductory elements of the bifurcation theory, and (6) physiological aspects in fluid dynamics.
Hypervolemia from Drinking Hyperhydration Solutions at Rest and Exercise
NASA Technical Reports Server (NTRS)
Greenleaf, John E.; Looft-Wilson, Robin; Jackson, Catherine G. R.; Geelen, Ghislaine; Barnes, Paul R.; Jensen, Christopher D.; Whittam, James H.
1995-01-01
The mechanism of muscular fatigue from physical work and exercise (high metabolism) is not clear, but involves disturbances of muscle surface membrane excitation-contraction coupling from changes in sarcoplasmic reticulum Ca2+ release, cell H+ and Pi responses, and carbohydrate metabolism. Fatigue in people at rest (low metabolism) involves both psychological and physiological factors, probably in different proportions. One common factor appears to be the level and distribution of water and electrolytes within muscle cells and other vascular, interstitial, body fluid compartments. The vascular fluid volume, composed of plasma and red blood cells, is a primary regulatory factor for cardiovascular function; reduction of vascular volume (hypovolemia) and total body water (hypohydration) adversely affect exercise performance. Plasma volume and plasma ionic-osmotic constituent concentrations are also regulatory factors for body thermoregulation, which is often compromised from exercise induced hypovolemia and hypohydration. Rehydration of dehydrated people on earth is relatively easy with appropriate food (osmols), fluid, and a restful environment. But ad libitum drinking under stressful conditions; e.g., heat, exercise, or prior dehydration, results in involuntary dehydration defined as the delay in full fluid replacement (euhydration) during and following loss of body fluid. Astronauts, with their reduced total body water are euhydrated while in weightlessness, but become "dehydrated" during reentry and landing. Thus, people subjected to acute or chronic stress are probably somewhat "dehydrated" as well as fatigued. Many rehydration drinks are more concentrated (hypertonic-hyperosmotic) with respect to the normal plasma osmolality of 285 mOsm/kg H2O and more of the drink osmols are contributed by carbohydrates than by ionized substances. There have been few studies on the efficacy of various drink formulations for increasing body fluid compartment volumes, especially plasma volume, in rested hydrated subjects. Recent findings from our laboratory have indicated that drinks containing greater concentrations of ionized substances (Performance 1 and AstroAde) up to 157 mEq/L Na+ induced greater levels of hypervolemia in resting, moderately dehydrated men, and were also better than water for attenuating the characteristic hypovolemia during supine, submaximal, leg ergometer exercise.
Nwanyanwu, O C; Tabasuri, T H; Harris, G R
1989-08-01
In 1982 the Centers for Disease Control published a set of recommendations and measures to protect persons working in health care settings or performing mortician services from possible exposure to the human immunodeficiency virus. This study of a number of funeral homes in the Fort Worth area was designed to determine the level of exposure of funeral home workers to blood and other body fluids and also to assess existing protective measures and practices in the industry. Workers in 22 funeral home franchises were surveyed with a predesigned questionnaire. Eighty-five responses from 20 of the 22 establishments were received. All 85 respondents admitted exposure of varying degrees to blood and body fluids. Sixty persons (70%) admitted heavy exposure, that is, frequent splashes. Analysis of the responses showed that 81 of 85 (95.3%) persons consistently wore gloves while performing tasks that might expose them to blood or other body fluids. Of the 60 persons who were heavily exposed, 43 wore long-sleeved gowns, 27 wore waterproof aprons, 17 surgical masks, and 15 goggles. The study further revealed that 52.9% (45/85) of the respondents had sustained accidental cuts or puncture wounds on the job. In light of these findings it is important to target educational efforts to persons in this industry to help them minimize their risks of infection with blood and body fluid borne infections.
Scaling of Counter-Current Imbibition Process in Low-Permeability Porous Media, TR-121
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kvoscek, A.R.; Zhou, D.; Jia, L.
2001-01-17
This project presents the recent work on imaging imbibition in low permeability porous media (diatomite) with X-ray completed tomography. The viscosity ratio between nonwetting and wetting fluids is varied over several orders of magnitude yielding different levels of imbibition performance. Also performed is mathematical analysis of counter-current imbibition processes and development of a modified scaling group incorporating the mobility ratio. This modified group is physically based and appears to improve scaling accuracy of countercurrent imbibition significantly.
NASA Astrophysics Data System (ADS)
Fitzpatrick, Richard
2017-12-01
'Theoretical Fluid Mechanics' has been written to aid physics students who wish to pursue a course of self-study in fluid mechanics. It is a comprehensive, completely self-contained text with equations of fluid mechanics derived from first principles, and any required advanced mathematics is either fully explained in the text, or in an appendix. It is accompanied by about 180 exercises with completely worked out solutions. It also includes extensive sections on the application of fluid mechanics to topics of importance in astrophysics and geophysics. These topics include the equilibrium of rotating, self-gravitating, fluid masses; tidal bores; terrestrial ocean tides; and the Eddington solar model.
Charged perfect fluid tori in strong central gravitational and dipolar magnetic fields
NASA Astrophysics Data System (ADS)
Kovář, Jiří; Slaný, Petr; Cremaschini, Claudio; Stuchlík, Zdeněk; Karas, Vladimír; Trova, Audrey
2016-06-01
We study electrically charged perfect fluid toroidal structures encircling a spherically symmetric gravitating object with Schwarzschild spacetime geometry and endowed with a dipole magnetic field. The work represents a direct continuation of our previous general-relativistic studies of electrically charged fluid in the approximation of zero conductivity, which formed tori around a Reissner-Nordström black hole or a Schwarzschild black hole equipped with a test electric charge and immersed in an asymptotically uniform magnetic field. After a general introduction of the zero-conductivity charged fluid model, we discuss a variety of possible topologies of the toroidal fluid configurations. Along with the charged equatorial tori forming interesting coupled configurations, we demonstrate the existence of the off-equatorial tori, for which the dipole type of magnetic field seems to be necessary. We focus on orbiting structures with constant specific angular momentum and on those in permanent rigid rotation. We stress that the general analytical treatment developed in our previous works is enriched here by the integrated form of the pressure equations. To put our work into an astrophysical context, we identify the central object with an idealization of a nonrotating magnetic neutron star. Constraining ranges of its parameters and also parameters of the circling fluid, we discuss a possible relevance of the studied toroidal structures, presenting along with their topology also pressure, density, temperature and charge profiles.
Particle sedimentation in a sheared viscoelastic fluid
NASA Astrophysics Data System (ADS)
Murch, William L.; Krishnan, Sreenath; Shaqfeh, Eric S. G.; Iaccarino, Gianluca
2017-11-01
Particle suspensions are ubiquitous in engineered processes, biological systems, and natural settings. For an engineering application - whether the intent is to suspend and transport particles (e.g., in hydraulic fracturing fluids) or allow particles to sediment (e.g., in industrial separations processes) - understanding and prediction of the particle mobility is critical. This task is often made challenging by the complex nature of the fluid phase, for example, due to fluid viscoelasticity. In this talk, we focus on a fully 3D flow problem in a viscoelastic fluid: a settling particle with a shear flow applied in the plane perpendicular to gravity (referred to as orthogonal shear). Previously, it has been shown that an orthogonal shear flow can reduce the settling rate of particles in viscoelastic fluids. Using experiments and numerical simulations across a wide range of sedimentation and shear Weissenberg number, this talk will address the underlying physical mechanism responsible for the additional drag experienced by a rigid sphere settling in a confined viscoelastic fluid with orthogonal shear. We will then explore multiple particle effects, and discuss the implications and extensions of this work for particle suspensions. This material is based upon work supported by the National Science Foundation Graduate Research Fellowship under Grant No. DGE-114747 (WLM).
Liu, De-Fang; Yan, Jiao; Guo, Ming-Yang; Wang, Chao; Hu, Yong-He; Yang, Min; Yun, Ming-Dong; Luo, Yong; Zhang, Jun; Li, Hua
2014-03-01
To probe the function of interleukin-17 (IL-17) in rheumatoid arthritis (RA) patients of accumulated dampness-heat obstruction in joints syndrome (ADOJS) by detecting levels of IL-17 in serum and the synovial fluid and analyzing its correlation with erythrocyte sedimentation rate (ESR) and C reactive protein (CRP). From January 2011 to January 2013, recruited were 90 RA inpatients of ADOJS at Department of Integrative Medical Rheumatism, General Hospital of Chengdu Military Region, of which 28 patients had knee joint effusion. Besides, 30 healthy volunteers who received physical examination at our hospital were recruited as the normal control group, and 30 patients with osteoarthritis (OA) who had knee joint effusion were recruited as the synovial fluid control group. The expression levels of IL-17 in serum and the synovial fluid were detected by enzyme linked immunosorbent assay (ELISA), and contents of ESR and CRP were detected in RA patients. Then correlation analyses were performed between levels of IL-17 and contents of ESR and CRP. Compared with the normal serum control group, the expression levels of IL-17 in serum of RA patients significantly increased (P < 0.05). Compared with the serum of RA patients and the synovial fluid of OA patients, the expression levels of IL-17 in the synovial fluid of RA patients significantly increased (P < 0.05). The expression levels of IL-17 in serum of RA patients were not correlated with ESR or CRP (r = 0.092, -0.082; P > 0.05), and the expressional levels of IL-17 in the synovial fluid of RA patients were not correlated with ESR or CRP (r = 0.113, -0.034; P > 0.05). IL-17 was the main effector cytokine of Th17 cells. The expressional levels of IL-17 significantly increased in serum and the synovial fluid of RA patients of ADOJS, but with no correlation to ESR or CRP. It indicated that IL-17 participated in the occurrence and development of RA. Concrete mechanisms needed to be further proved in larger samples.
Choice of optimal working fluid for binary power plants at extremely low temperature brine
NASA Astrophysics Data System (ADS)
Tomarov, G. V.; Shipkov, A. A.; Sorokina, E. V.
2016-12-01
The geothermal energy development problems based on using binary power plants utilizing lowpotential geothermal resources are considered. It is shown that one of the possible ways of increasing the efficiency of heat utilization of geothermal brine in a wide temperature range is the use of multistage power systems with series-connected binary power plants based on incremental primary energy conversion. Some practically significant results of design-analytical investigations of physicochemical properties of various organic substances and their influence on the main parameters of the flowsheet and the technical and operational characteristics of heat-mechanical and heat-exchange equipment for binary power plant operating on extremely-low temperature geothermal brine (70°C) are presented. The calculation results of geothermal brine specific flow rate, capacity (net), and other operation characteristics of binary power plants with the capacity of 2.5 MW at using various organic substances are a practical interest. It is shown that the working fluid selection significantly influences on the parameters of the flowsheet and the operational characteristics of the binary power plant, and the problem of selection of working fluid is in the search for compromise based on the priorities in the field of efficiency, safety, and ecology criteria of a binary power plant. It is proposed in the investigations on the working fluid selection of the binary plant to use the plotting method of multiaxis complex diagrams of relative parameters and characteristic of binary power plants. Some examples of plotting and analyzing these diagrams intended to choose the working fluid provided that the efficiency of geothermal brine is taken as main priority.
IGF-I and NEFA concentrations in fetal fluids of term pregnancy dogs.
Meloni, Tea; Comin, Antonella; Rota, Alessandro; Peric, Tanja; Contri, Alberto; Veronesi, Maria Cristina
2014-06-01
Insulin-like growth factor-I (IGF-I) and non-esterified fatty acids (NEFA) play an essential role in fetal growth and development. To date, fetal fluids IGF-I and NEFA levels at term canine pregnancy are unknown and could be related to the neonatal development and breed size. For these reasons, the aims of the present study were as follows: (1) to evaluate IGF-I and NEFA concentrations in fetal fluids collected from normally developed and viable newborn puppies born at term of normal pregnancies; (2) to assess possible differences between IGF-I and NEFA levels in amniotic compared with allantoic fluid; (3) to detect possible relationship between breed body size and IGF-I and NEFA amniotic and allantoic concentrations; (4) to evaluate possible differences in IGF-I fetal fluids levels between male and female puppies; and (5) to assess possible correlations between the two hormones in each type of fluid. The study enrolled 25 pure breed bitches submitted to elective Cesarean section at term because of the high risk of dystocia or previous troubles at parturition. At surgery, amniotic and allantoic fluids were collected and assayed for IGF-I and NEFA. IGF-I and NEFA amounts in both amniotic and allantoic fluids of different breed size bitches (small: ≤10 kg; medium: 11-25 kg; large: 26-40 kg) were detected, as well as the effect of gender on IGF-I levels. On a total of 73 amniotic and 76 allantoic samples collected by normal, viable, and mature newborns, the mean IGF-I concentration was significantly higher in amniotic than in allantoic fluid in all three groups, but the amniotic IGF-I levels were significantly lower in small and medium size bitches when compared with large ones. No significant differences were found in allantoic IGF-I concentrations among size groups. A significant effect of the puppy gender on IGF-I content in both fetal fluids was not reported. Regarding NEFA, in all the three groups, the mean NEFA concentration did not significantly differ between amnion and allantois, but in both fetal fluids, higher NEFA levels were detected in samples belonging to small breeds when compared with medium and large. These data strongly indicated that, also in the dog, a relation between fetal fluids IGF-I and NEFA concentrations and breed size exists. Further research is needed to elucidate the possible role of IGF-I and NEFA in the pathologic conditions related to canine fetal growth. Copyright © 2014 Elsevier Inc. All rights reserved.
Vitberg, Yaffa M; Tseng, Peggy; Kessler, David O
2018-05-01
Our objective was to describe the sonographic appearance of fluid at clinically selected interspinous spaces and see if additional interspaces could be identified as suitable and safe targets for needle insertion. We also measured the reproducibility of fluid measurements and assessed for positional differences. A prospective convenience sample of infants younger than 3 months was enrolled in the pediatric emergency department. Excluded were clinically unstable infants or those with spinal dysraphism. Infants were first held in standard lateral lumbar puncture position. Pediatric emergency medicine (PEM) physicians marked infants' backs at the level they would insert a needle using the landmark palpation technique. A PEM sonologist imaged and measured the spinal fluid in 2 orthogonal planes at this marked level in lateral then sitting positions. Fluid measurements were repeated by a second blinded PEM sonologist. Forty-six infants were enrolled. Ultrasound verified the presence of fluid at the marked level as determined by the landmark palpation technique in 98% of cases. Ultrasound identified additional suitable spaces 1 space higher (82%) and 2 spaces higher (41%). Intraclass correlation coefficient of all measurements was excellent (>0.85), with differences noted for sitting versus lateral position in mean area of fluid 0.34 mm versus 0.31 mm (difference, 0.03; 95% confidence interval [CI], 0.005-0.068), dorsal fluid pocket 0.23 mm versus 0.15 mm (difference, 0.08; 95% CI, 0.031-0.123), and nerve root-to-canal ratio 0.44 versus 0.51 (difference, 0.07; 95% CI, 0.004-0.117). Ultrasound can verify the presence of fluid at interspaces determined by the landmark palpation technique and identify additional suitable spaces at higher levels. There were statistically greater fluid measurements in sitting versus lateral positions. These novel fluid measurements were shown to be reliable.
Performance of Fuels, Lubricants, and Associated Products Used during Operation Desert Shield/Storm
1992-08-01
to have enabled the. units to perform their mission. However, most units reported taking enough hydi aulic fluid with them to Southwest Asia, while...Fluid Lubncant for Extreme Climates " Sand does not mick to at Did not work good on 30mm MG on Apache Did not work for "coax" guns on Bradley Crew
Generator-absorber-heat exchange heat transfer apparatus and method and use thereof in a heat pump
Phillips, B.A.; Zawacki, T.S.
1998-07-21
Numerous embodiments and related methods for generator-absorber heat exchange (GAX) are disclosed, particularly for absorption heat pump systems. Such embodiments and related methods use, as the heat transfer medium, the working fluid of the absorption system taken from the generator at a location where the working fluid has a rich liquor concentration. 5 figs.
Generator-absorber-heat exchange heat transfer apparatus and method and use thereof in a heat pump
Phillips, Benjamin A.; Zawacki, Thomas S.
1998-07-21
Numerous embodiments and related methods for generator-absorber heat exchange (GAX) are disclosed, particularly for absorption heat pump systems. Such embodiments and related methods use, as the heat transfer medium, the working fluid of the absorption system taken from the generator at a location where the working fluid has a rich liquor concentration.
Better Gas-Gap Thermal Switches For Sorption Compressors
NASA Technical Reports Server (NTRS)
Bhandari, Pradeep; Rodriguez, Jose
1995-01-01
Gas-gap thermal switches associated with sorption compressors of some heat pumps and cryogenic systems designed for higher performance, according to proposal, by introducing controlled turbulent flows into gas gaps. Utilizes convection in turbulent flow to transfer heat at greater rate. Design takes advantage of flow of working fluid. Working fluid also serve as heat transfer medium in gas gap.
Green-McKenzie, Judith; Shofer, Frances S
2007-01-01
Shift work has been found to be associated with an increased rate of errors and accidents among healthcare workers (HCWs), but the effect of shift work on accidental blood and body fluid exposure sustained by HCWs has not been well characterized. To determine the duration of time on shift before accidental blood and body fluid exposure in housestaff, nurses, and technicians and the proportion of housestaff who sustain a blood and body fluid exposure after 12 hours on duty. This retrospective, descriptive study was conducted during a 24-month period at a large urban teaching hospital. Participants were HCWs who sustained an accidental blood and body fluid exposure. Housestaff were on duty significantly longer than both nursing staff (P=.02) and technicians (P<.0001) before accidental blood and body fluid exposure. Half of the blood and body fluid exposures sustained by housestaff occurred after being on duty 8 hours or more, and 24% were sustained after being on duty 12 hours or more. Of all HCWs, 3% reported an accidental blood and body fluid exposure, with specific rates of 7.9% among nurses, 9.4% among housestaff, and 3% among phlebotomists. Housestaff were significantly more likely to have longer duration of time on shift before blood and body fluid exposure than were the other groups. Almost one-quarter of accidental blood and body fluid exposures to housestaff were incurred after they had been on duty for 12 hours or more. Housestaff sustained a higher rate of accidental blood and body fluid exposures than did nursing staff and technicians.
NASA Astrophysics Data System (ADS)
Hakkarainen, Elina; Sihvonen, Teemu; Lappalainen, Jari
2017-06-01
Supercritical carbon dioxide (sCO2) has recently gained a lot of interest as a working fluid in different power generation applications. For concentrated solar power (CSP) applications, sCO2 provides especially interesting option if it could be used both as the heat transfer fluid (HTF) in the solar field and as the working fluid in the power conversion unit. This work presents development of a dynamic model of CSP plant concept, in which sCO2 is used for extracting the solar heat in Linear Fresnel collector field, and directly applied as the working fluid in the recuperative Brayton cycle; these both in a single flow loop. We consider the dynamic model is capable to predict the system behavior in typical operational transients in a physically plausible way. The novel concept was tested through simulation cases under different weather conditions. The results suggest that the concept can be successfully controlled and operated in the supercritical region to generate electric power during the daytime, and perform start-up and shut down procedures in order to stay overnight in sub-critical conditions. Besides the normal daily operation, the control system was demonstrated to manage disturbances due to sudden irradiance changes.
NASA Astrophysics Data System (ADS)
Rao, Zhonghao; Wang, Qingchao; Zhao, Jiateng; Huang, Congliang
2017-10-01
To investigate the thermal performance of the closed oscillating heat pipe (OHP) as a passive heat transfer device in thermal management system, the gravitation force, surface tension, cooling section position and inclination angle were discussed with applied heating power ranging from 5 to 65 W. The deionized water was chosen as the working fluid and liquid-filling ratio was 50 ± 5%. The operation of the OHP mainly depends on the phase change of the working fluid. The working fluid within the OHP was constantly evaporated and cooled. The results show that the movement of the working fluid was similar to the forced damped mechanical vibration, it has to overcome the capillary resistance force and the stable oscillation should be that the OHP could successful startup. The oscillation frequency slowed and oscillation amplitude decreased when the inclination angle of the OHP increased. However, the thermal resistance increased. With the increment of the heating power, the average temperature of the evaporation and condensation section would be close. If the heating power was further increased, dry-out phenomenon within the OHP would appeared. With the decrement of the L, the start-up heating power also decreased and stable oscillation would be formed.
Construction of Joule Thomson inversion curves for mixtures using equation of state
NASA Astrophysics Data System (ADS)
Patankar, A. S.; Atrey, M. D.
2017-02-01
The Joule-Thomson effect is at the heart of Joule-Thomson cryocoolers and gas liquefaction cycles. The effective harnessing of this phenomenon necessitates the knowledge of Joule-Thomson coefficient and the inversion curve. When the working fluid is a mixture, (in mix refrigerant Joule-Thomson cryocooler, MRJT) the phase diagrams, equations of state and inversion curves of multi-component systems become important. The lowest temperature attainable by such a cryocooler depends on the inversion characteristics of the mixture used. In this work the construction of differential Joule-Thomson inversion curves of mixtures using Redlich-Kwong, Soave-Redlich-Kwong and Peng-Robinson equations of state is investigated assuming single phase. It is demonstrated that inversion curves constructed for pure fluids can be improved by choosing an appropriate value of acentric factor. Inversion curves are used to predict maximum inversion temperatures of multicomponent systems. An application where this information is critical is a two-stage J-T cryocooler using a mixture as the working fluid, especially for the second stage. The pre-cooling temperature that the first stage is required to generate depends on the maximum inversion temperature of the second stage working fluid.
Reeve, Gordon R; Stout, Allen W; Hands, David; Curry, Emmanuel
2003-11-01
This study was undertaken to determine the impact of exposure to metal removal fluids (MRFs) on the respiratory health of exposed workers. The outcome measure selected was the rate of hospital admissions for nonmalignant respiratory disease episodes as determined from healthcare insurance claims data. A cohort of MRF-exposed employees was assembled from 11 manufacturing facilities where MRFs were extensively used in the manufacture of automotive engines, transmissions, and other machined parts. The MRF-exposed cohort included 20,434 employees of such facilities who worked at any time from 1993 through 1997. A non-MRF-exposed cohort was assembled from other employees of the same company during the same time period, but working in warehouse operations and other manufacturing facilities that did not use MRFs or any known respiratory sensitizing agents. The non-exposed cohort included 8681 employees. The crude hospital admission rate for the MRF-exposed cohort was 44 percent higher than that of the non-exposed cohort over the 5-year study period (6.67 vs. 4.62 per 1000 person years at risk, p < 0.05). With age adjustment, the MRF population's rate was still 35 percent higher, and still statistically significant. A nested case-control study was also conducted to determine whether the risk of hospital admission increased with the level of MRF exposure in the population working in MRF plants. The industrial hygiene reconstruction found the levels of exposures of both cases and controls to be very low, with the vast majority of study subjects (more than 90%) having exposures of less than 0.5 mg/m(3). The case-control study did not find any association between increased levels of MRF exposure and risk of hospitalization. The study did document an elevated risk of hospitalization among a sizable population employed in manufacturing operations where MRFs are used.
Vandrey, Ryan; Herrmann, Evan S; Mitchell, John M; Bigelow, George E; Flegel, Ronald; LoDico, Charles; Cone, Edward J
2017-03-01
Most research on cannabis pharmacokinetics has evaluated inhaled cannabis, but oral ("edible") preparations comprise an increasing segment of the cannabis market. To assess oral cannabis pharmacokinetics and pharmacodynamics, healthy adults (N = 6 per dose) were administered cannabis brownies containing 10, 25 or 50 mg 9-tetrahydrocannabinol (THC). Whole blood and oral fluid specimens were obtained at baseline and then for 9 days post-exposure; 6 days in a residential research setting and 3 days as outpatients. Measures of subjective, cardiovascular and performance effects were obtained at baseline and for 8 h post-ingestion. The mean Cmax for THC in whole blood was 1, 3.5 and 3.3 ng/mL for the 10, 25 and 50 mg THC doses, respectively. The mean maximum concentration (Cmax) and mean time to maximum concentration (Tmax) of 11-OH-THC in whole blood were similar to THC. Cmax blood concentrations of THCCOOH were generally higher than THC and had longer Tmax values. The mean Tmax for THC in oral fluid occurred immediately following oral dose administration, and appear to reflect local topical residue rather than systemic bioavailbility. Mean Cmax oral fluid concentrations of THCCOOH were lower than THC, erratic over time and mean Tmax occurred at longer times than THC. The window of THC detection ranged from 0 to 22 h for whole blood (limit of quantitation (LOQ) = 0.5 ng/mL) and 1.9 to 22 h for oral fluid (LOQ = 1.0 ng/mL). Subjective drug and cognitive performance effects were generally dose dependent, peaked at 1.5-3 h post-administration, and lasted 6-8 h. Whole blood cannabinoid concentrations were significantly correlated with subjective drug effects. Correlations between blood cannabinoids and cognitive performance measures, and between oral fluid and all pharmacodynamic outcomes were either non-significant or not orderly by dose. Quantitative levels of cannabinoids in whole blood and oral fluid were low compared with levels observed following inhalation of cannabis. The route of administration is important for interpretation of cannabinoid toxicology. Published by Oxford University Press 2017. This work is written by (a) US Government employee(s) and is in the public domain in the US.
Screening and confirmation of microRNA markers for forensic body fluid identification.
Wang, Zheng; Zhang, Ji; Luo, Haibo; Ye, Yi; Yan, Jing; Hou, Yiping
2013-01-01
MicroRNAs (miRNAs, ∼22 nucleotides) are small, non-protein coding RNAs that regulate gene expression at the post-transcriptional level. MiRNAs can express in a tissue-specific manner, and have been introduced to forensic body fluid identification. In this study, we employed the qPCR-array (TaqMan(®) Array Human MicroRNA Cards) to screen the body fluid-specific miRNAs. Seven candidate miRNAs were identified as potentially body fluid-specific and could be used as forensically relevant body fluid markers: miR16 and miR486 for venous blood, miR888 and miR891a for semen, miR214 for menstrual blood, miR124a for vaginal secretions, and miR138-2 for saliva. The candidate miRNA markers were then validated via hydrolysis probes quantitative real-time polymerase chain reaction (TaqMan-qPCR). In addition, BestKeeper software was used to validate the expression stability of four genes, RNU44, RNU48, U6 and U6b, regularly used as reference genes (RGs) for studies involving forensic body fluids. The current study suggests that U6 could be used as a proper RG of miRNAs in forensic body fluid identification. The relative expression ratios (R) of miR486, miR888, miR214, miR16 and miR891a can differentiate the target body fluid from other body fluids that were tested in this study. The detection limit of TaqMan-qPCR of the five confirmed miRNA markers was 10pg of total RNA. The effect of time-wise degradation of blood stains and semen stains for 1 month under normal laboratory conditions was tested and did not significantly affect the detection results. Herein, this study proposes five body fluid-specific miRNAs for the forensic identification of venous blood, semen, and menstrual blood, of which miR486, miR888, and miR214 may be used as new markers for body fluid identification. Additional work remains necessary in search for suitable miRNA markers and stable RGs for forensic body fluid identification. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Double-reed exhaust valve engine
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bennett, Charles L.
An engine based on a reciprocating piston engine that extracts work from pressurized working fluid. The engine includes a double reed outlet valve for controlling the flow of low-pressure working fluid out of the engine. The double reed provides a stronger force resisting closure of the outlet valve than the force tending to open the outlet valve. The double reed valve enables engine operation at relatively higher torque and lower efficiency at low speed, with lower torque, but higher efficiency at high speed.
Design and Development of Low-Cost Water Tunnel for Educational Purpose
NASA Astrophysics Data System (ADS)
Zahari, M.; Dol, S. S.
2015-04-01
The hydrodynamic behaviour of immersed body is essential in fluid dynamics study. Water tunnel is an example of facility required to provide a controlled condition for fluid flow research. The operational principle of water tunnel is quite similar to the wind tunnel but with different working fluid and higher flow-pumping capacity. Flow visualization in wind tunnel is more difficult to conduct as turbulent flows in wind dissipate quickly whilst water tunnel is more suitable for such purpose due to higher fluid viscosity and wide variety of visualization techniques can be employed. The present work focusses on the design and development of open flow water tunnel for the purpose of studying vortex-induced vibration from turbulent vortex shedding phenomenon. The water tunnel is designed to provide a steady and uniform flow speed within the test section area. Construction details are discussed for development of low-cost water tunnel for quantitative and qualitative fluid flow measurements. The water tunnel can also be used for educational purpose such as fluid dynamics class activity to provide quick access to visualization medium for better understanding of various turbulence motion learnt in class.
Piro, M.H.A; Wassermann, F.; Grundmann, S.; ...
2017-05-23
The current work presents experimental and computational investigations of fluid flow through a 37 element CANDU nuclear fuel bundle. Experiments based on Magnetic Resonance Velocimetry (MRV) permit three-dimensional, three-component fluid velocity measurements to be made within the bundle with sub-millimeter resolution that are non-intrusive, do not require tracer particles or optical access of the flow field. Computational fluid dynamic (CFD) simulations of the foregoing experiments were performed with the hydra-th code using implicit large eddy simulation, which were in good agreement with experimental measurements of the fluid velocity. Greater understanding has been gained in the evolution of geometry-induced inter-subchannel mixing,more » the local effects of obstructed debris on the local flow field, and various turbulent effects, such as recirculation, swirl and separation. These capabilities are not available with conventional experimental techniques or thermal-hydraulic codes. Finally, the overall goal of this work is to continue developing experimental and computational capabilities for further investigations that reliably support nuclear reactor performance and safety.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Piro, M.H.A; Wassermann, F.; Grundmann, S.
The current work presents experimental and computational investigations of fluid flow through a 37 element CANDU nuclear fuel bundle. Experiments based on Magnetic Resonance Velocimetry (MRV) permit three-dimensional, three-component fluid velocity measurements to be made within the bundle with sub-millimeter resolution that are non-intrusive, do not require tracer particles or optical access of the flow field. Computational fluid dynamic (CFD) simulations of the foregoing experiments were performed with the hydra-th code using implicit large eddy simulation, which were in good agreement with experimental measurements of the fluid velocity. Greater understanding has been gained in the evolution of geometry-induced inter-subchannel mixing,more » the local effects of obstructed debris on the local flow field, and various turbulent effects, such as recirculation, swirl and separation. These capabilities are not available with conventional experimental techniques or thermal-hydraulic codes. Finally, the overall goal of this work is to continue developing experimental and computational capabilities for further investigations that reliably support nuclear reactor performance and safety.« less
Moya, Eva M.; Chavez-Baray, Silvia Maria; Martinez, Omar; Mattera, Brian; Adcox, Courtney
2018-01-01
Research and scholarship efforts continue to promote the integration of micro and macro practice in social work practice and education. Despite this, scholarship has documented persistent challenges in the fluid integration between the domains of micro-level service provision and macro-level social change efforts in practice and academic programs. This paper outlines a successful bridge between the micro-macro divide in the form of community-engaged practice to address homelessness and social work education in the U.S.-Mexico border region. MSW students enrolled in a macro-level course at the University of Texas at El Paso’s College of Health Sciences successfully partnered with the Opportunity Center for the Homeless, a grassroots community-based organization serving individuals experiencing homelessness. The narrative describes how students were effectively able to apply both micro- and macro-level skills learned in the classroom to an experiential learning environment while providing much-needed assistance to an underfunded community-based organization. A set of challenges and recommendations are also discussed. Research initiatives are needed to evaluate and test clinical and community work initiatives, including the use of photovoice methodology to address homelessness, while being responsive to community needs and challenges. PMID:29809204
Moya, Eva M; Chavez-Baray, Silvia Maria; Martinez, Omar; Mattera, Brian; Adcox, Courtney
2018-01-01
Research and scholarship efforts continue to promote the integration of micro and macro practice in social work practice and education. Despite this, scholarship has documented persistent challenges in the fluid integration between the domains of micro-level service provision and macro-level social change efforts in practice and academic programs. This paper outlines a successful bridge between the micro-macro divide in the form of community-engaged practice to address homelessness and social work education in the U.S.-Mexico border region. MSW students enrolled in a macro-level course at the University of Texas at El Paso's College of Health Sciences successfully partnered with the Opportunity Center for the Homeless, a grassroots community-based organization serving individuals experiencing homelessness. The narrative describes how students were effectively able to apply both micro- and macro-level skills learned in the classroom to an experiential learning environment while providing much-needed assistance to an underfunded community-based organization. A set of challenges and recommendations are also discussed. Research initiatives are needed to evaluate and test clinical and community work initiatives, including the use of photovoice methodology to address homelessness, while being responsive to community needs and challenges.
Chockalingam, P S; Glasson, S S; Lohmander, L S
2013-02-01
We have previously shown the capacity of tenascin-C (TN-C) to induce inflammatory mediators and matrix degradation in vitro in human articular cartilage. The objective of the present study was to follow TN-C release into knee synovial fluid after acute joint injury or in joint disease, and to correlate TN-C levels with markers of cartilage matrix degradation and inflammation. Human knee synovial fluid samples (n = 164) were from a cross-sectional convenience cohort. Diagnostic groups were knee healthy reference, knee anterior cruciate ligament rupture, with or without concomitant meniscus lesions, isolated knee meniscus injury, acute inflammatory arthritis (AIA) and knee osteoarthritis (OA). TN-C was measured in synovial fluid samples using an enzyme-linked immunosorbent assay (ELISA) and results correlated to other cartilage markers. TN-C release was also monitored in joints of dogs that underwent knee instability surgery. Statistically significantly higher levels of TN-C compared to reference subjects were observed in the joint fluid of all human disease groups and in the dogs that underwent knee instability surgery. Statistically significant correlations were observed between the TN-C levels in the synovial fluid of the human patients and the levels of aggrecanase-dependent Ala-Arg-Gly-aggrecan (ARG-aggrecan) fragments and matrix metalloproteinases 1 and 3. We find highly elevated levels of TN-C in human knee joints after injury, AIA or OA that correlated with markers of cartilage degradation and inflammation. TN-C in synovial fluid may serve dual roles as a marker of joint damage and a stimulant of further joint degradation. Copyright © 2012 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.
Advances in Constraining Solubilities of H-O-C-S-Cl-bearing Fluids in Silicate Melts
NASA Astrophysics Data System (ADS)
Webster, J. D.
2009-12-01
Magmatic-hydrothermal fluids that are variably enriched in the volatile components H2O, CO2/CH4, H2S/SO2, Cl, F, ± B alter rock; dissolve, transport, and deposit ore metals, and drive volcanism. The efficacy of these processes varies directly with the compositions and quantities, and in particular, with the molar volumes of the fluids involved. Although natural hydrothermal fluids are geochemically diverse, experimental constraints on volatile solubilities in silicate melts are largely limited to two volatiles. Recent experimental research, however, has begun to address mutual solubility relationships of three and four volatiles in felsic to intermediate aluminosilicate melts at shallow crustal pressures. Following well-established correlations demonstrating that as little as a few hundred to thousand ppm CO2 or Cl reduce H2O solubility in melts, and hence enhance the tendency for magma to exsolve one or two fluid phases, recent work shows fundamentally important solubility relationships involving H2O, S, and Cl. Research on rhyodacitic (Botcharnikov et al., 2004) and phonolitic melts at 200 MPa reveals that hundreds to thousands of ppm S will reduce Cl solubility in these melts. Thus, S reduces Cl solubility, which in turn reduces H2O solubility in melts. Other investigations have determined that CaSO4 solubility in oxidizing hydrothermal fluids varies directly with the concentrations of NaCl ± KCl in these fluids (Newton and Manning, 2005; Webster et al., 2009). The CaSO4 contents in the most alkali chloride-enriched fluids exceed 60 wt.%. It follows that some mineralizing saline magmatic fluids are strongly enriched in Ca, Na, K, Cl, SO4, and reduced S species. Research on H2O-, CO2-, and Cl-bearing melts at 200 MPa also highlights critical reciprocal volatile solubility behavior. Work at 1200°C on andesitic melts saturated in two fluids determines that the presence of CO2 enlarges the immiscibility gap for vapor plus brine and increases the activities of H2O and Cl (Botcharnikov et al. 2007). Conversely, other work involving Cl-enriched phonolitic melts plus two fluids at 900°C observes that the presence of Cl strongly reduces CO2 solubility in the melt. In fact, for runs containing as much as 80 mole percent CO2 in the fluid, the CO2/CO3 contents of the melts were reduced to values below the limit of detection for FTIR (< ca. 30-40 ppm). Thus, Cl works to reduce CO2 solubility, which in turn reduces H2O solubility in phonolitic melts. Current work on the solubility of H-O-C-S in haplogranitic melts at 200 MPa demonstrates that the addition of C reduces the (fluid/melt) partition coefficient for S. In addition, these experimentally determined partition coefficients decrease in the order CO2 > S > H2O, and their ranges are virtually identical to and thus confirm modeled values computed (Scaillet and Pichavant, 2003) for pre-eruptive magmatic fluids based on volatile fugacities of volcanic gases of arc-related magmas. Botcharnikov R et al (2004) Chem. Geol. 213, 207-225. Botcharnikov R, Holtz F, Behrens H (2007) Eur. J. Mineral. 19, 671-680. Newton R, Manning C (2005) J. Petrol. 46, 701-716. Scaillet B, Pichavant M (2003) Volcanic Degassing, Geol. Soc. Spec. Pub. 213, 23-52. Webster J, Sintoni M, De Vivo B (2009) Chem. Geol. 263, 19-36.
MEASUREMENT OF TRACE LEVELS OF DEUTERIUM OXIDE IN BIOLOGIC FLUIDS USING INFRARED SPECTROPHOTOMETRY.
Experimental data relevant to the assay of D2O in human serum, urine, and parotid fluid are presented. For serum, with triplicate scans, values of precision...and of accuracy of plus or minus 3% at the 250 p.p.m. D2O level are obtained. By use of parotid fluid the values are narrowed to plus or minus 2% at...aqueous compartments using values for serum water content. Parotid fluid appears to be particularly suitable for biomedical applications due to its ease
Dual manifold heat pipe evaporator
Adkins, Douglas R.; Rawlinson, K. Scott
1994-01-01
An improved evaporator section for a dual manifold heat pipe. Both the upper and lower manifolds can have surfaces exposed to the heat source which evaporate the working fluid. The tubes in the tube bank between the manifolds have openings in their lower extensions into the lower manifold to provide for the transport of evaporated working fluid from the lower manifold into the tubes and from there on into the upper manifold and on to the condenser portion of the heat pipe. A wick structure lining the inner walls of the evaporator tubes extends into both the upper and lower manifolds. At least some of the tubes also have overflow tubes contained within them to carry condensed working fluid from the upper manifold to pass to the lower without spilling down the inside walls of the tubes.
Liao, Huai; Na, Moon Jun; Dikensoy, Oner; Lane, Kirk B; Randal, Barnette; Light, Richard W
2008-01-01
The diagnosis of the cause of pleural effusions caused by cardiovascular diseases such as congestive heart failure (CHF) and acute pulmonary embolism is sometimes difficult. The purpose of the present study was to evaluate the utility of pleural fluid levels of N-terminal pro-brain natriuretic peptide (NT-proBNP) in differentiating pleural effusions due to CHF, pulmonary embolism and post-coronary artery bypass graft (CABG) surgery. The levels of pleural fluid NT-proBNP were measured by ELISA in a total of 40 patients: 10 with CHF, 10 with pulmonary embolism, 10 post-CABG and 10 with carcinoma. The median level of NT-proBNP in the pleural fluid of patients with CHF was 5390 pg/mL (25th to 75th percentiles, 4566 to 8158 pg/mL), which was significantly higher than that in patients with post-CABG effusions (424 pg/mL, 352 to 873), with pulmonary embolism (311 pg/mL, 212 to 1159), or with carcinoma (302 pg/mL, 208 to 626) (P < 0.001, CHF group vs all other groups). In receiver-operating curve analysis, an NT-proBNP level of >or=2220 pg/mL demonstrated a sensitivity of 100% and a specificity of 96.7% for the identification of CHF. Measurement of the NT-proBNP level in pleural fluid is accurate in diagnosing the etiology of the effusion as CHF. Pleural fluid levels above 2220 pg/mL are essentially diagnostic that the pleural effusion is due to CHF.
Solid He: Progress, Status, and Outlook for Mass Flux Measurements
NASA Astrophysics Data System (ADS)
Hallock, R. B.
2015-07-01
After a brief introduction, what is provided there is brief summary of work with solid He done at the University of Massachusetts Amherst and an outlook for future work. What is presented here is based on a presentation made at the Quantum Gases Fluids and Solids Workshop in Sao Paulo, Brazil in August of 2014. Our work with solid He is aimed at the question: Can a sample cell filled with solid He support a mass flux through the cell? The answer, as will be shown here, is yes. Evidence for this from several types of experiments will be reviewed. There will be an emphasis on more recent work, work that explores how the flux observed depends on temperature and on the He impurity level. The behavior observed suggests that solid He may be an example of a material that demonstrates Bosonic Luttinger liquid behavior. The normalized He flux has a universal temperature dependence. The presence of He at different impurity levels shows that the He blocks the flux at a characteristic temperature. The behavior appears to be consistent with the cores of dislocations as the entity that carries the flux, but it is clear that more work needs to be done to fully understand solid He.
The Maze of the Cerebrospinal Fluid Discovery
2013-01-01
The author analyzes a historical, long, and tortuous way to discover the cerebrospinal fluid. At least 35 physicians and anatomists described in the text have laid the fundamentals of recognition of this biological fluid's presence. On the basis of crucial anatomical, experimental, and clinical works there are four greatest physicians who should be considered as equal cerebrospinal fluid's discoverers: Egyptian Imhotep, Venetian Nicolo Massa, Italian Domenico Felice Cotugno, and French François Magendie. PMID:24396600
The subscale orbital fluid transfer experiment
NASA Technical Reports Server (NTRS)
Collins, Frank G.; Antar, Basil N.; Menzel, Reinhard W.; Meserole, Jere S.; Meserole, Jere S.; Jones, Ogden
1990-01-01
The Subscale Orbital Fluid Transfer Experiment (SOFTE) is a planned Shuttle Orbiter fluid transfer experiment. CASP (Center for Advanced Space Propulsion) performed certain aspects of the conceptual design of this experiment. The CASP work consisted of the conceptual design of the optical system, the search for alternative experimental fluids, the determination of the flow meter specifications and the examination of materials to use for a bladder that will empty one of the tanks in the experiment.
Martínez Carapeto, Isabel; López Castilla, José Domingo; Fresneda Gutiérrez, Reyes
2017-11-11
To compare plasma glucose levels and incidence of hyperglycaemia in the post-operative period after general surgery using fluids with different glucose. A randomised, open-label, non-blind, clinical trial was conducted on patients admitted to Paediatric Intensive Care Unit after elective surgery. The inclusion criteria were from 6 months to 14 years of age, with a weight greater than 6kg, onset glucose level >60mg/dL, and a signed informed consent, with no oral intake and maintenance intravenous fluid therapy using fluids with 3.3% or 5% glucose. Plasma glucose levels were measured before surgery, on admission, and 8, 24, and 48h, with the mean glucose levels and incidence of hyperglycaemia (glucose level >150mg/dL) in both groups being compared. A total of 60 patients received glucose/saline 1/3 (51mEq/L sodium and 33g/L glucose), and 70 glucose/saline 5/0.9% (154mEq/L sodium and 50g/L glucose). Mean glucose levels were higher in the group receiving glucose 5%, with no statistical difference. There was no significant difference in the incidence of hyperglycaemia; 8h: 26% in the 3.3% group vs. 21.3% in the 5% group (P=.63); 24h: 20% vs. 22.7% (P=.8); and 48h: 19% vs. 23.1% (P=.78). The use of fluids with 3.3% glucose in the post-operative period of general surgery maintains mean glucose levels in a similar range to that of patients receiving fluids with 5% glucose, with no difference in the incidence of hyperglycaemia. Copyright © 2017. Publicado por Elsevier España, S.L.U.
Rudebeck, Sarah R.; Bor, Daniel; Ormond, Angharad; O’Reilly, Jill X.; Lee, Andy C. H.
2012-01-01
One current challenge in cognitive training is to create a training regime that benefits multiple cognitive domains, including episodic memory, without relying on a large battery of tasks, which can be time-consuming and difficult to learn. By giving careful consideration to the neural correlates underlying episodic and working memory, we devised a computerized working memory training task in which neurologically healthy participants were required to monitor and detect repetitions in two streams of spatial information (spatial location and scene identity) presented simultaneously (i.e. a dual n-back paradigm). Participants’ episodic memory abilities were assessed before and after training using two object and scene recognition memory tasks incorporating memory confidence judgments. Furthermore, to determine the generalizability of the effects of training, we also assessed fluid intelligence using a matrix reasoning task. By examining the difference between pre- and post-training performance (i.e. gain scores), we found that the trainers, compared to non-trainers, exhibited a significant improvement in fluid intelligence after 20 days. Interestingly, pre-training fluid intelligence performance, but not training task improvement, was a significant predictor of post-training fluid intelligence improvement, with lower pre-training fluid intelligence associated with greater post-training gain. Crucially, trainers who improved the most on the training task also showed an improvement in recognition memory as captured by d-prime scores and estimates of recollection and familiarity memory. Training task improvement was a significant predictor of gains in recognition and familiarity memory performance, with greater training improvement leading to more marked gains. In contrast, lower pre-training recollection memory scores, and not training task improvement, led to greater recollection memory performance after training. Our findings demonstrate that practice on a single working memory task can potentially improve aspects of both episodic memory and fluid intelligence, and that an extensive training regime with multiple tasks may not be necessary. PMID:23209740
Rudebeck, Sarah R; Bor, Daniel; Ormond, Angharad; O'Reilly, Jill X; Lee, Andy C H
2012-01-01
One current challenge in cognitive training is to create a training regime that benefits multiple cognitive domains, including episodic memory, without relying on a large battery of tasks, which can be time-consuming and difficult to learn. By giving careful consideration to the neural correlates underlying episodic and working memory, we devised a computerized working memory training task in which neurologically healthy participants were required to monitor and detect repetitions in two streams of spatial information (spatial location and scene identity) presented simultaneously (i.e. a dual n-back paradigm). Participants' episodic memory abilities were assessed before and after training using two object and scene recognition memory tasks incorporating memory confidence judgments. Furthermore, to determine the generalizability of the effects of training, we also assessed fluid intelligence using a matrix reasoning task. By examining the difference between pre- and post-training performance (i.e. gain scores), we found that the trainers, compared to non-trainers, exhibited a significant improvement in fluid intelligence after 20 days. Interestingly, pre-training fluid intelligence performance, but not training task improvement, was a significant predictor of post-training fluid intelligence improvement, with lower pre-training fluid intelligence associated with greater post-training gain. Crucially, trainers who improved the most on the training task also showed an improvement in recognition memory as captured by d-prime scores and estimates of recollection and familiarity memory. Training task improvement was a significant predictor of gains in recognition and familiarity memory performance, with greater training improvement leading to more marked gains. In contrast, lower pre-training recollection memory scores, and not training task improvement, led to greater recollection memory performance after training. Our findings demonstrate that practice on a single working memory task can potentially improve aspects of both episodic memory and fluid intelligence, and that an extensive training regime with multiple tasks may not be necessary.
NASA Astrophysics Data System (ADS)
Bejarano, Roberto Villa
Cold-start performance enhancement of a pump-assisted, capillary-driven, two-phase cooling loop was attained using proportional integral and fuzzy logic controls to manage the boiling condition inside the evaporator. The surface tension of aqueous solutions of n-Pentanol, a self-rewetting fluid, was also investigated for enhancing heat transfer performance of capillary driven (passive) thermal devices was also studied. A proportional-integral control algorithm was used to regulate the boiling condition (from pool boiling to thin-film boiling) and backpressure in the evaporator during cold-start and low heat input conditions. Active flow control improved the thermal resistance at low heat inputs by 50% compared to the baseline (constant flow rate) case, while realizing a total pumping power savings of 56%. Temperature overshoot at start-up was mitigated combining fuzzy-logic with a proportional-integral controller. A constant evaporator surface temperature of 60°C with a variation of +/-8°C during start-up was attained with evaporator thermal resistances as low as 0.10 cm2--K/W. The surface tension of aqueous solutions of n-Pentanol, a self-rewetting working fluid, as a function of concentration and temperature were also investigated. Self-rewetting working fluids are promising in two-phase heat transfer applications because they have the ability to passively drive additional working fluid towards the heated surface; thereby increasing the dryout limitations of the thermal device. Very little data is available in literature regarding the surface tension of these fluids due to the complexity involved in fluid handling, heating, and experimentation. Careful experiments were performed to investigate the surface tension of n-Pentanol + water. The concentration and temperature range investigated were from 0.25%wt. to1.8%wt and 25°C to 85°C, respectively.
The pdf approach to turbulent polydispersed two-phase flows
NASA Astrophysics Data System (ADS)
Minier, Jean-Pierre; Peirano, Eric
2001-10-01
The purpose of this paper is to develop a probabilistic approach to turbulent polydispersed two-phase flows. The two-phase flows considered are composed of a continuous phase, which is a turbulent fluid, and a dispersed phase, which represents an ensemble of discrete particles (solid particles, droplets or bubbles). Gathering the difficulties of turbulent flows and of particle motion, the challenge is to work out a general modelling approach that meets three requirements: to treat accurately the physically relevant phenomena, to provide enough information to address issues of complex physics (combustion, polydispersed particle flows, …) and to remain tractable for general non-homogeneous flows. The present probabilistic approach models the statistical dynamics of the system and consists in simulating the joint probability density function (pdf) of a number of fluid and discrete particle properties. A new point is that both the fluid and the particles are included in the pdf description. The derivation of the joint pdf model for the fluid and for the discrete particles is worked out in several steps. The mathematical properties of stochastic processes are first recalled. The various hierarchies of pdf descriptions are detailed and the physical principles that are used in the construction of the models are explained. The Lagrangian one-particle probabilistic description is developed first for the fluid alone, then for the discrete particles and finally for the joint fluid and particle turbulent systems. In the case of the probabilistic description for the fluid alone or for the discrete particles alone, numerical computations are presented and discussed to illustrate how the method works in practice and the kind of information that can be extracted from it. Comments on the current modelling state and propositions for future investigations which try to link the present work with other ideas in physics are made at the end of the paper.
On the fluid dynamics of a laboratory scale single-use stirred bioreactor
Odeleye, A.O.O.; Marsh, D.T.J.; Osborne, M.D.; Lye, G.J.; Micheletti, M.
2014-01-01
The commercial success of mammalian cell-derived recombinant proteins has fostered an increase in demand for novel single-use bioreactor (SUB) systems that facilitate greater productivity, increased flexibility and reduced costs (Zhang et al., 2010). These systems exhibit fluid flow regimes unlike those encountered in traditional glass/stainless steel bioreactors because of the way in which they are designed. With such disparate hydrodynamic environments between SUBs currently on the market, traditional scale-up approaches applied to stirred tanks should be revised. One such SUB is the Mobius® 3 L CellReady, which consists of an upward-pumping marine scoping impeller. This work represents the first experimental study of the flow within the CellReady using a Particle Image Velocimetry (PIV) approach, combined with a biological study into the impact of these fluid dynamic characteristics on cell culture performance. The PIV study was conducted within the actual vessel, rather than using a purpose-built mimic. PIV measurements conveyed a degree of fluid compartmentalisation resulting from the up-pumping impeller. Both impeller tip speed and fluid working volume had an impact upon the fluid velocities and spatial distribution of turbulence within the vessel. Cell cultures were conducted using the GS-CHO cell-line (Lonza) producing an IgG4 antibody. Disparity in cellular growth and viability throughout the range of operating conditions used (80–350 rpm and 1–2.4 L working volume) was not substantial, although a significant reduction in recombinant protein productivity was found at 350 rpm and 1 L working volume (corresponding to the highest Reynolds number tested in this work). The study shows promise in the use of PIV to improve understanding of the hydrodynamic environment within individual SUBs and allows identification of the critical hydrodynamic parameters under the different flow regimes for compatibility and scalability across the range of bioreactor platforms. PMID:24864128
On the fluid dynamics of a laboratory scale single-use stirred bioreactor.
Odeleye, A O O; Marsh, D T J; Osborne, M D; Lye, G J; Micheletti, M
2014-05-24
The commercial success of mammalian cell-derived recombinant proteins has fostered an increase in demand for novel single-use bioreactor (SUB) systems that facilitate greater productivity, increased flexibility and reduced costs (Zhang et al., 2010). These systems exhibit fluid flow regimes unlike those encountered in traditional glass/stainless steel bioreactors because of the way in which they are designed. With such disparate hydrodynamic environments between SUBs currently on the market, traditional scale-up approaches applied to stirred tanks should be revised. One such SUB is the Mobius ® 3 L CellReady, which consists of an upward-pumping marine scoping impeller. This work represents the first experimental study of the flow within the CellReady using a Particle Image Velocimetry (PIV) approach, combined with a biological study into the impact of these fluid dynamic characteristics on cell culture performance. The PIV study was conducted within the actual vessel, rather than using a purpose-built mimic. PIV measurements conveyed a degree of fluid compartmentalisation resulting from the up-pumping impeller. Both impeller tip speed and fluid working volume had an impact upon the fluid velocities and spatial distribution of turbulence within the vessel. Cell cultures were conducted using the GS-CHO cell-line (Lonza) producing an IgG 4 antibody. Disparity in cellular growth and viability throughout the range of operating conditions used (80-350 rpm and 1-2.4 L working volume) was not substantial, although a significant reduction in recombinant protein productivity was found at 350 rpm and 1 L working volume (corresponding to the highest Reynolds number tested in this work). The study shows promise in the use of PIV to improve understanding of the hydrodynamic environment within individual SUBs and allows identification of the critical hydrodynamic parameters under the different flow regimes for compatibility and scalability across the range of bioreactor platforms.
Influence of the cooling degree upon performances of internal combustion engine
NASA Astrophysics Data System (ADS)
Grǎdinariu, Andrei Cristian; Mihai, Ioan
2016-12-01
Up to present, air cooling systems still raise several unsolved problems due to conditions imposed by the environment in terms of temperature and pollution levels. The present paper investigates the impact of the engine cooling degree upon its performances, as important specific power is desired for as low as possible fuel consumption. A technical solution advanced by the authors[1], consists of constructing a bi-flux compressor, which can enhance the engine's performances. The bi-flux axial compressor accomplishes two major functions, that is it cools down the engine and it also turbocharges it. The present paper investigates the temperature changes corresponding to the fresh load, during the use of a bi-flux axial compressor. This compressor is economically simple, compact, and offers an optimal response at low rotational speeds of the engine, when two compression steps are used. The influence of the relative coefficient of air temperature drop upon working agent temperature at the intercooler exit is also investigated in the present work. The variation of the thermal load coefficient by report to the working agent temperature is also investigated during engine cooling. The variation of the average combustion temperature is analyzed in correlation to the thermal load coefficient and the temperatures of the working fluid at its exit from the cooling system. An exergetic analysis was conducted upon the influence of the cooling degree on the motor fluid and the gases resulted from the combustion process.
Pleural fluid neopterin levels in tuberculous pleurisy.
Cok, Gursel; Parildar, Zuhal; Basol, Gunes; Kabaroglu, Ceyda; Bayindir, Ulku; Habif, Sara; Bayindir, Oya
2007-08-01
Neopterin is produced by stimulated macrophages under the influence of gamma interferon of lymphocyte origin. It is regarded as a biochemical marker of cell-mediated immune response. This study was designed to assess the diagnostic value of pleural fluid neopterin levels in tuberculous pleurisy in comparison with adenosine deaminase activity. Pleural fluid adenosine deaminase (ADA) activity and neopterin levels were measured in 16 patients with tuberculous pleurisy (TP) and 19 patients with malignant pleurisy (MP). ADA activity was determined by a colorimetric method, whereas neopterin levels were determined by a reversed-phase liquid chromatography technique. All values were given as median (min-max). The mean age was 45.43+/-20.39 years in the TP group and 60.42+/-11.02 years in the MP group (p=0.026). The median pleural fluid ADA activity was 51.75 U/L (3.50-62.40 U/L) in the TP group and was 2.30 U/L (1-8.20 U/L) in the MP group. The difference was statistically significant (p<0.001). The median pleural fluid neopterin levels were 13.15 nmol/L (1.86-59.50 nmol/L) and 2.44 nmol/L (0.92-27.60 nmol/L) in the TP group and the MP group, respectively (p=0.021). In order to evaluate the diagnostic value of pleural fluid neopterin concentrations, receiver-operating-characteristic curve analysis was performed. Pleural fluid neopterin concentration is significantly higher in TP when compared to MP, however when compared, its clinical use as a diagnostic marker is not valuable as ADA.
2009-07-08
ISS020-E-018121 (8 July 2009) --- European Space Agency astronaut Frank De Winne, Expedition 20 flight engineer, works with the Fluid Servicing System (FSS) in the Columbus laboratory of the International Space Station.
2009-07-08
ISS020-E-018118 (8 July 2009) --- European Space Agency astronaut Frank De Winne, Expedition 20 flight engineer, works with the Fluid Servicing System (FSS) in the Columbus laboratory of the International Space Station.
Role of Laryngopharyngeal Reflux in the Pathogenesis of Otitis Media with Effusion.
Doğru, Mehmet; Kuran, Gökhan; Haytoğlu, Süheyl; Dengiz, Ramazan; Arıkan, Osman Kürşat
2015-04-01
To determine whether there is an association between otitis media with effusion and laryngopharyngeal reflux in children. This study included 31 children with otitis media with effusion. The pepsinogen level in the middle ear fluid of all patients was measured by sandwich enzyme-linked immunosorbent assay. Each patient's middle ear fluid was investigated for Helicobacter pylori (H. pylori) using the Campylobacter-like organism (CLO) test. The middle ear pepsinogen levels were compared with those in the serum. The correlation between pepsinogen levels and H. pylori positivity in the middle ear fluid was investigated. The mean middle ear pepsinogen level (211.69 ng/mL) was significantly higher than that in the serum (24.18 ng/mL) in patients with otitis media with effusion. The middle ear aspirates of six patients (19%) were positive for H. pylori, and the correlation between H. pylori positivity and increased pepsinogen levels in the middle ear fluid was statistically significant in patients with otitis media with effusion. We detected higher pepsinogen levels and H. pylori positivity rates in the middle ear fluid than in the serum of patients with otitis media with effusion. These results support the role of laryngopharyngeal reflux in the pathogenesis of otitis media with effusion.
Öngöz Dede, F; Balli, U; Bozkurt Doğan, Ş; Güven, B
2017-06-01
The cytokine, interleukin (IL)-32, is a relatively new discovery. However, it is very powerful for stimulating tumor necrosis factor-alpha (TNF-α) under inflammatory conditions. The objective of this research was to explore fluctuations in the levels of TNF-α, IL-32 and IL-10, in both saliva and gingival crevicular fluid. The focus was on measurements taken before and after clinical treatment of chronic periodontitis. For the purposes of the study, a total of 27 patients with chronic periodontitis and 27 controls (periodontally healthy) were recruited. Important clinical periodontal criteria were established before and 4 wk after the start of the research. The chronic periodontitis group was given an initial form of periodontal care. Samples of saliva and gingival crevicular fluid were collected exactly 4 wk preceding and 4 wk following the care. The levels of IL-10, IL-32 and TNF-α present in saliva and gingival crevicular fluid were recorded via the use of an ELISA. At baseline, the levels of TNF-α and IL-32 in the gingival crevicular fluid and saliva were significantly higher among patients in the chronic periodontitis group than among patients in the control group (p < 0.05). On the other hand, at baseline the levels of IL-10 were significantly lower in the gingival crevicular fluid and saliva of the chronic periodontitis group than the control group (p < 0.05). A significantly positive link was found between the TNF-α and IL-32 levels in the two study groups (p < 0.05). After treatment, the levels of TNF-α and IL-32 in saliva and gingival crevicular fluid were significantly lower in the chronic periodontitis group when compared with the baseline readings. However, the levels of IL-10 were significantly higher (p < 0.05). Ultimately, the level of IL-32 present in saliva and gingival crevicular fluid might be useful as an indicator of the condition and the expectations for its treatment and care. According to the results of the research, the proinflammatory impact of IL-32 could potentially be linked to the intensity and progression of periodontitis. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Dialysis fluid endotoxin level and mortality in maintenance hemodialysis: a nationwide cohort study.
Hasegawa, Takeshi; Nakai, Shigeru; Masakane, Ikuto; Watanabe, Yuzo; Iseki, Kunitoshi; Tsubakihara, Yoshiharu; Akizawa, Tadao
2015-06-01
The quality of dialysis fluid water might play an important role in hemodialysis patient outcomes. Although targeted endotoxin levels of dialysis fluid vary among countries, evidence of the contribution of these levels to mortality in hemodialysis patients is lacking. Retrospective cohort study using data from the Japan Renal Data Registry, a nationwide annual survey. 130,781 patients receiving thrice-weekly in-center hemodialysis for more than 6 months were enrolled at 2,746 facilities in Japan at the end of 2006. None of the patients changed facility or treatment modality during 2007. Highest endotoxin level in dialysis fluid reported by each facility during 2006. Patients were categorized by facility endotoxin level into the following groups: <0.001, 0.001 to <0.01, 0.01 to <0.05, 0.05 to <0.1, and ≥0.1EU/mL. Age, sex, dialysis vintage, diabetes mellitus as a primary cause of end-stage renal disease, Kt/V, normalized protein catabolic rate, dialysis session duration, serum albumin, and hemoglobin were measured as potential confounders. All-cause mortality, censored by transplantation; withdrawal from dialysis treatment; or end of follow-up. Of 130,781 hemodialysis patients, 91.2% had facility endotoxin levels below the limit set for dialysis fluid in Japan (<0.05EU/mL). During a 1-year follow-up, 8,978 (6.9%) patients died of all causes. The rate of all-cause mortality at 1 year was highest in the ≥0.1-EU/mL category (88.0 deaths/1,000 person-years). Patients in the ≥0.1-EU/mL group exhibited an increased risk of all-cause mortality of 28% (95% CI, 10%-48%) compared to the <0.001-EU/mL group. Endotoxin level in dialysis fluid is reported as categorical data. No information about variation in endotoxin levels in dialysis fluid over time. Higher facility endotoxin levels in dialysis fluid may be related to increased risk for all-cause mortality among hemodialysis patients. Correcting this modifiable facility water management practice might improve the outcome of hemodialysis patients. Copyright © 2015 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.
Wåhlén, K; Fornander, L; Olausson, P; Ydreborg, K; Flodin, U; Graff, P; Lindahl, M; Ghafouri, B
2016-10-01
Upper airway irritation is common among individuals working in moldy and damp buildings. The aim of this study was to investigate effects on the protein composition of the nasal lining fluid. The prevalence of symptoms in relation to work environment was examined in 37 individuals working in two damp buildings. Microbial growth was confirmed in one of the buildings. Nasal lavage fluid was collected from 29 of the exposed subjects and 13 controls, not working in a damp building. Protein profiles were investigated with a proteomic approach and evaluated by multivariate statistical models. Subjects from both workplaces reported upper airway and ocular symptoms. Based on protein profiles, symptomatic subjects in the two workplaces were discriminated from each other and separated from healthy controls. The groups differed in proteins involved in inflammation and host defense. Measurements of innate immunity proteins showed a significant increase in protein S100-A8 and decrease in SPLUNC1 in subjects from one workplace, while alpha-1-antitrypsin was elevated in subjects from the other workplace, compared with healthy controls. The results show that protein profiles in nasal lavage fluid can be used to monitor airway mucosal effects in personnel working in damp buildings and indicate that the profile may be separated when the dampness is associated with the presence of molds. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Dust as a Working Fluid for Heat Transfer Project
NASA Technical Reports Server (NTRS)
Mantovani, James G.
2015-01-01
The project known as "Dust as a Working Fluid" demonstrates the feasibility of a dust-based system for transferring heat radiatively into space for those space applications requiring higher efficiency, lower mass, and the need to operate in extreme vacuum and thermal environments - including operating in low or zero gravity conditions in which the dust can be conveyed much more easily than on Earth.
Energy management system for a rotary machine and method therefor
Bowman, Michael John; Sinha, Gautam; Sheldon, Karl Edward
2004-11-09
In energy management system is provided for a power generating device having a working fluid intake in which the energy management system comprises an electrical dissipation device coupled to the power generating device and a dissipation device cooling system configured to direct a portion of a working fluid to the electrical dissipation device so as to provide thermal control to the electrical dissipation device.
ERIC Educational Resources Information Center
Burgess, Gregory C.; Gray, Jeremy R.; Conway, Andrew R. A.; Braver, Todd S.
2011-01-01
Fluid intelligence (gF) and working memory (WM) span predict success in demanding cognitive situations. Recent studies show that much of the variance in gF and WM span is shared, suggesting common neural mechanisms. This study provides a direct investigation of the degree to which shared variance in gF and WM span can be explained by neural…
Bacterial adenosine triphosphate as a measure of urinary tract infection
NASA Technical Reports Server (NTRS)
Chappelle, E. W.; Picciolo, G. L.
1971-01-01
Procedure detects and counts bacteria present in urine samples. Method also determines bacterial levels in other aqueous body fluids including lymph fluid, plasma, blood, spinal fluid, saliva and mucous.
Quantity not quality: The relationship between fluid intelligence and working memory capacity
Fukuda, Keisuke; Vogel, Edward; Mayr, Ulrich; Awh, Edward
2010-01-01
A key motivation for understanding capacity in working memory (WM) is its relationship with fluid intelligence. Recent evidence has suggested a 2-factor model that distinguishes between the number of representations that can be maintained in WM and the resolution of those representations. To determine how these factors relate to fluid intelligence, we conducted an exploratory factor analysis on multiple number-limited and resolution-limited measures of WM ability. The results strongly supported the 2-factor model, with fully orthogonal factors accounting for performance in the number-limited and resolution-limited conditions. Furthermore, the reliable relationship between WM capacity and fluid intelligence was exclusively supported by the number factor (r = .66), while the resolution factor made no reliable contribution (r = −.05). Thus, the relationship between WM capacity and standard measures of fluid intelligence is mediated by the number of representations that can be simultaneously maintained in WM rather than by the precision of those representations. PMID:21037165
A symbiotic approach to fluid equations and non-linear flux-driven simulations of plasma dynamics
NASA Astrophysics Data System (ADS)
Halpern, Federico
2017-10-01
The fluid framework is ubiquitous in studies of plasma transport and stability. Typical forms of the fluid equations are motivated by analytical work dating several decades ago, before computer simulations were indispensable, and can be, therefore, not optimal for numerical computation. We demonstrate a new first-principles approach to obtaining manifestly consistent, skew-symmetric fluid models, ensuring internal consistency and conservation properties even in discrete form. Mass, kinetic, and internal energy become quadratic (and always positive) invariants of the system. The model lends itself to a robust, straightforward discretization scheme with inherent non-linear stability. A simpler, drift-ordered form of the equations is obtained, and first results of their numerical implementation as a binary framework for bulk-fluid global plasma simulations are demonstrated. This material is based upon work supported by the U.S. Department of Energy, Office of Science, Office of Fusion Energy Sciences, Theory Program, under Award No. DE-FG02-95ER54309.
Microgravity Fluids for Biology, Workshop
NASA Technical Reports Server (NTRS)
Griffin, DeVon; Kohl, Fred; Massa, Gioia D.; Motil, Brian; Parsons-Wingerter, Patricia; Quincy, Charles; Sato, Kevin; Singh, Bhim; Smith, Jeffrey D.; Wheeler, Raymond M.
2013-01-01
Microgravity Fluids for Biology represents an intersection of biology and fluid physics that present exciting research challenges to the Space Life and Physical Sciences Division. Solving and managing the transport processes and fluid mechanics in physiological and biological systems and processes are essential for future space exploration and colonization of space by humans. Adequate understanding of the underlying fluid physics and transport mechanisms will provide new, necessary insights and technologies for analyzing and designing biological systems critical to NASAs mission. To enable this mission, the fluid physics discipline needs to work to enhance the understanding of the influence of gravity on the scales and types of fluids (i.e., non-Newtonian) important to biology and life sciences. In turn, biomimetic, bio-inspired and synthetic biology applications based on physiology and biology can enrich the fluid mechanics and transport phenomena capabilities of the microgravity fluid physics community.
Continuum-kinetic-microscopic model of lung clearance due to core-annular fluid entrainment
Mitran, Sorin
2013-01-01
The human lung is protected against aspirated infectious and toxic agents by a thin liquid layer lining the interior of the airways. This airway surface liquid is a bilayer composed of a viscoelastic mucus layer supported by a fluid film known as the periciliary liquid. The viscoelastic behavior of the mucus layer is principally due to long-chain polymers known as mucins. The airway surface liquid is cleared from the lung by ciliary transport, surface tension gradients, and airflow shear forces. This work presents a multiscale model of the effect of airflow shear forces, as exerted by tidal breathing and cough, upon clearance. The composition of the mucus layer is complex and variable in time. To avoid the restrictions imposed by adopting a viscoelastic flow model of limited validity, a multiscale computational model is introduced in which the continuum-level properties of the airway surface liquid are determined by microscopic simulation of long-chain polymers. A bridge between microscopic and continuum levels is constructed through a kinetic-level probability density function describing polymer chain configurations. The overall multiscale framework is especially suited to biological problems due to the flexibility afforded in specifying microscopic constituents, and examining the effects of various constituents upon overall mucus transport at the continuum scale. PMID:23729842
Dalmarco, Eduardo Monguilhott; Medeiros, Yara Santos
2008-01-01
The mouse model of pleurisy induced by carrageenan is characterized by a significant enhancement of cell migration due to neutrophils 4 h after pleurisy induction. Forty-eight hours after pleurisy induction, a significant increase in cell migration due to mononuclear cells occurs. Recently, studies in our laboratory have demonstrated that cyclosporine A (CsA) inhibits leukocyte migration in the pleural cavity and lungs in the mouse model of pleurisy induced by carrageenan. In the present work we evaluated whether CsA was able to downregulate CD11a/CD18 adhesion molecule in the lungs, as well as TNFα and IL-1β levels in the fluid leakage of the pleural cavity in this model. Our results showed that CsA significantly decreased CD11a/CD18 in the lungs, as well as TNFα and IL-1β levels in the fluid leakage of the pleural cavity 4 h and 48 h after pleurisy induction. It is our hypothesis that the inhibitory effect elicited by CsA upon these adhesion molecules may be also be attributed to the downregulation of TNFα and IL-1β cytokines. PMID:19262158
Continuum-kinetic-microscopic model of lung clearance due to core-annular fluid entrainment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mitran, Sorin, E-mail: mitran@unc.edu
2013-07-01
The human lung is protected against aspirated infectious and toxic agents by a thin liquid layer lining the interior of the airways. This airway surface liquid is a bilayer composed of a viscoelastic mucus layer supported by a fluid film known as the periciliary liquid. The viscoelastic behavior of the mucus layer is principally due to long-chain polymers known as mucins. The airway surface liquid is cleared from the lung by ciliary transport, surface tension gradients, and airflow shear forces. This work presents a multiscale model of the effect of airflow shear forces, as exerted by tidal breathing and cough,more » upon clearance. The composition of the mucus layer is complex and variable in time. To avoid the restrictions imposed by adopting a viscoelastic flow model of limited validity, a multiscale computational model is introduced in which the continuum-level properties of the airway surface liquid are determined by microscopic simulation of long-chain polymers. A bridge between microscopic and continuum levels is constructed through a kinetic-level probability density function describing polymer chain configurations. The overall multiscale framework is especially suited to biological problems due to the flexibility afforded in specifying microscopic constituents, and examining the effects of various constituents upon overall mucus transport at the continuum scale.« less
An assay for the assessment of lipocortin 1 levels in human lung lavage fluid.
Smith, S F; Goulding, N J; Godolphin, J L; Tetley, T D; Roberts, C M; Guz, A; Flower, R J
1990-07-20
The physiological function of the lipocortins, proteins which are thought to be glucocorticoid-regulated, is unclear. An improved assay for lipocortins might help to elucidate their role. A rapid and specific sandwich enzyme-linked immunosorbent assay (ELISA) for lipocortin 1 with a working range of 1-2000 ng/ml and an interrun coefficient of variation of less than 10% is described and used in this pilot study to quantify human lipocortin 1 for the first time in acellular bronchoalveolar lavage fluid (BALF), and in media conditioned by BAL cells, from control patients and those with pulmonary sarcoidosis. Using this assay a statistically significant relationship, not previously observed in man, has been demonstrated between concentrations of lipocortin 1/ml of BALF and serum cortisol levels (n = 10, rs = 0.6939, P less than 0.05). Although lipocortin 1 levels in acellular BALF were the same in control and sarcoid patients, significantly more lipocortin 1 was released from sarcoid BAL cells in culture (median 21.6, range 8.1-45.4 ng lipocortin/10(6) cells/h in culture) than from control cells (2.5, 1.5-7.6 ng lipocortin/10(6) cells/h in culture). The possible clinical significance of these data is discussed, but remains to be established.
Lee, Royce; Petty, Frederick; Coccaro, Emil F
2009-01-01
The objective of this study was to assess the relationship between cerebrospinal fluid concentrations of the neurotransmitter gamma-aminobutyric acid (GABA) and measures of impulsivity and related behaviors (aggression and suicidality) in healthy volunteer and personality disordered subjects. CSF GABA levels, and measures of impulsivity, aggression, and history of suicidal behavior were obtained by morning lumbar puncture in 57 healthy volunteer subjects and in subjects with personality disorder. CSF GABA levels were not found to correlate with measures of aggression but were found to correlate directly with measures of impulsivity; e.g., a composite measure of impulsivity in all subjects (r=0.35, df=46, P=0.015) and in personality disordered subjects examined separately (r=0.39, df=30, P=0.029). In the personality disorder group, CSF GABA levels were higher among subjects with a history of suicidal behavior compared with those without this history. These data suggest that central GABAergic function correlates directly with impulsiveness and history of suicidal behavior, but not aggressiveness, in personality disordered subjects. This may be consistent with observations that high doses of benzodiazepines can lead to "behavioral disinhibition" in human subjects. Further work assessing this and other aspects of the central GABA system in personality disordered subjects are warranted.
Continuum-kinetic-microscopic model of lung clearance due to core-annular fluid entrainment
NASA Astrophysics Data System (ADS)
Mitran, Sorin
2013-07-01
The human lung is protected against aspirated infectious and toxic agents by a thin liquid layer lining the interior of the airways. This airway surface liquid is a bilayer composed of a viscoelastic mucus layer supported by a fluid film known as the periciliary liquid. The viscoelastic behavior of the mucus layer is principally due to long-chain polymers known as mucins. The airway surface liquid is cleared from the lung by ciliary transport, surface tension gradients, and airflow shear forces. This work presents a multiscale model of the effect of airflow shear forces, as exerted by tidal breathing and cough, upon clearance. The composition of the mucus layer is complex and variable in time. To avoid the restrictions imposed by adopting a viscoelastic flow model of limited validity, a multiscale computational model is introduced in which the continuum-level properties of the airway surface liquid are determined by microscopic simulation of long-chain polymers. A bridge between microscopic and continuum levels is constructed through a kinetic-level probability density function describing polymer chain configurations. The overall multiscale framework is especially suited to biological problems due to the flexibility afforded in specifying microscopic constituents, and examining the effects of various constituents upon overall mucus transport at the continuum scale.
NASA Astrophysics Data System (ADS)
Besedina, A. N.; Vinogradov, E. A.; Gorbunova, E. M.; Kabychenko, N. V.; Svintsov, I. S.; Pigulevskiy, P. I.; Svistun, V. K.; Shcherbina, S. V.
2015-01-01
The first part of this work is dedicated to the response of different-age structures to lunisolar tides, which can be considered as a sounding signal for monitoring the state of fluid-saturated reservoirs. The complex approach to processing the data obtained at the testing sites of the Institute of Geosphere Dynamics of the Russian Academy of Sciences, Institute of Geophysics of the National Academy of Sciences of Ukraine, and KIEV station of the IRIS seismic network is applied for recognizing the tides against the hydrogeological, barometric, and seismic series. The comparative analysis of the experimental and theoretical values of the diurnal and semidiurnal tidal components in the time series of ground displacements is carried out. The tidal variations in the groundwater level are compared with the tidal components revealed in the ground displacement of the different-age structure of the Moscow Basin and Ukrainian Shield, which are parts of the East European artesian region. The differences in the tidal responses of the groundwater level and ground displacement probably suggest that the state of the massif is affected by certain additional factors associated, e.g., with the passage of earthquake-induced seismic waves and the changes in the hydrogeodynamic environment.
Satellite Servicing Capabilities Office Testing
NASA Technical Reports Server (NTRS)
Sanders, Sean
2015-01-01
While at the KSC, I was given the opportunity of assisting the Satellite Servicing Capabilities Office (SSCO) specifically the Propellant Transfer System (PTS) lead by my mentor, Brian Nufer. While waiting to test different components in the PTS, I was able to assist with testing for the Hose Management Assembly (HMA) and was able to work on a simulation in Labview. For the HMA, I was able to help with testing of a coating as well as to help test the durability of the pinch rollers in space. In Labview, I experimented with building a simulation for the PTS, to show where fluids and gases were flowing depending on which valves in the PTS were opened. Not all of the integrated parts required assembly level testing, which allowed me to test these parts individually by myself and document the results. I was also able to volunteer to assist project NEO, allowing me to gain some knowledge of cryogenic fluid systems.
Bioremediation of aircraft deicing fluids (glycol) at airports. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gallagher, D.W.
1998-09-01
This report describes the work done to determine the effectiveness of various aerobic bioremediation techniques for reducing the biochemical oxygen demand (BOD) of aircraft deicing fluid runoff. Primary emphasis has been placed on laboratory and field demonstrations of bioremediation systems using various combinations of inocula (bacteria), nutrient mixes, enzyme mixes, and ultrasonic stimulation. Laboratory experiments with a variety of inocula and nutrients together with enzymes and ultrasound are demonstrated showing the importance of the appropriate bacteria and nutrient mix in bioaugmentation. The appropriate mix was shown to significantly influence biodegradation. Deicing solutions were routinely reduced to acceptable BOD levels formore » effluent discharge in 3 days or less. In the field experiment, a special dual-tank bioreactor system was developed to demonstrate a pilot small-scale system. Experimental operation of this system confirmed that a 3-day or less remediation cycle was possible during the winter season.« less
NASA Astrophysics Data System (ADS)
Hamidnia, Mohammad; Luo, Yi; Wang, Xiaodong; Li, Congming
2017-10-01
Increasing component densities of the integrated circuit (IC) and packaging levels has led to thermal management problems. Si substrates with embedded micro-heat pipes (MHPs) couple good thermal characteristics and cost savings associated with IC batch processing. The thermal performance of MHP is intimately related to the cross-sectional geometry. Different cross-sections are designed in order to enhance the backflow of working fluid. In this experimental study, three different Si MHPs with same hydraulic diameter and various cross-sections are fabricated by micro-fabrication methods and tested under different conditions of fluid charge ratios. The results show that the trapezoidal MHP associated with rectangular artery which is charged with 40% of vapor chamber’s volume has the best thermal performance. This silicon-based MHP is a passive approach for thermal management, which could widen applications in the commercial electronics industry and LED lightings.
Experimental evidence of a helical, supercritical instability in pipe flow of shear thinning fluids
NASA Astrophysics Data System (ADS)
Picaut, L.; Ronsin, O.; Caroli, C.; Baumberger, T.
2017-08-01
We study experimentally the flow stability of entangled polymer solutions extruded through glass capillaries. We show that the pipe flow becomes linearly unstable beyond a critical value (Wic≃5 ) of the Weissenberg number, via a supercritical bifurcation which results in a helical distortion of the extrudate. We find that the amplitude of the undulation vanishes as the aspect ratio L /R of the capillary tends to zero, and saturates for large L /R , indicating that the instability affects the whole pipe flow, rather than the contraction or exit regions. These results, when compared to previous theoretical and experimental works, lead us to argue that the nature of the instability is controlled by the level of shear thinning of the fluids. In addition, we provide strong hints that the nonlinear development of the instabiilty is mitigated, in our system, by the gradual emergence of gross wall slip.
NASA Astrophysics Data System (ADS)
Brutsaert, Wilfried
2005-08-01
Water in its different forms has always been a source of wonder, curiosity and practical concern for humans everywhere. Hydrology - An Introduction presents a coherent introduction to the fundamental principles of hydrology, based on the course that Wilfried Brutsaert has taught at Cornell University for the last thirty years. Hydrologic phenomena are dealt with at spatial and temporal scales at which they occur in nature. The physics and mathematics necessary to describe these phenomena are introduced and developed, and readers will require a working knowledge of calculus and basic fluid mechanics. The book will be invaluable as a textbook for entry-level courses in hydrology directed at advanced seniors and graduate students in physical science and engineering. In addition, the book will be more broadly of interest to professional scientists and engineers in hydrology, environmental science, meteorology, agronomy, geology, climatology, oceanology, glaciology and other earth sciences. Emphasis on fundamentals Clarification of the underlying physical processes Applications of fluid mechanics in the natural environment
Wilhelm, M; Ohnesorge, F K
1990-01-01
The influence of storage temperature, vessel type, and treatment on alterations of aluminum (Al) concentrations in serum, urine, and dialysis fluid samples was studied at three different concentrations for each sample over an 18-month period. Furthermore, the influence of acidification on Al levels in tap water, urine, and dialysis fluid samples was studied over a four-month period. Al was measured by atomic absorption spectrometry. Sample storage in glass vessels was unsuitable, whereas only minor alterations of Al levels were observed with storage in polypropylene tubes, polystyrene tubes, and Monovettes. By using appropriate plastic containers, acid washing of the vessels showed no improvement. Frozen storage was superior compared with 4 degrees C, whereas storage at -80 degrees C offered no advantage compared with storage at -20 degrees C. Acidification of tap water samples was necessary to stabilize Al levels during storage. No striking effect of acidification on Al levels in urine and dialysis fluid samples was found. It is concluded that longterm storage of serum, urine, tap water, and dialysis fluid samples is possible if appropriate conditions are used.
Enhancement of Boiling Heat Transfer in Di-Electric Fluids
1991-09-01
working fluid of R-I13. Maddox and Mudawar [Ref. 8] studied the effect of subcooling and surface aug- mentation on values of Critical Heat Flux (CHF). They...Enhanced Surfaces to Dielectric Fluids," A SME Journal of Heat Transfer, v.104, pp.292-299, May 1982. 8. Maddox D.E., and Mudawar ,I., "Single and Two
Novel Magnetic Fluids for Breast Cancer Therapy
2008-01-01
technology, in particular. The last one gave birth to the magnetic fluid hyperthermia (MFH) - an important tool for cancer treatment . Hyperthermia is...MODELING WORK In order to theoretically demonstrate the advantage of the novel magnetic nanoparticles for hyperthermia , we have developed a...AD_________________ Award Number: DAMD17-03-1-0176 TITLE: Novel Magnetic Fluids for Breast Cancer
Hypocapnic but Not Metabolic Alkalosis Impairs Alveolar Fluid Reabsorption
Myrianthefs, Pavlos M.; Briva, Arturo; Lecuona, Emilia; Dumasius, Vidas; Rutschman, David H.; Ridge, Karen M.; Baltopoulos, George J.; Sznajder, Jacob Iasha
2005-01-01
Acid-base disturbances, such as metabolic or respiratory alkalosis, are relatively common in critically ill patients. We examined the effects of alkalosis (hypocapnic or metabolic alkalosis) on alveolar fluid reabsorption in the isolated and continuously perfused rat lung model. We found that alveolar fluid reabsorption after 1 hour was impaired by low levels of CO2 partial pressure (PCO2; 10 and 20 mm Hg) independent of pH levels (7.7 or 7.4). In addition, PCO2 higher than 30 mm Hg or metabolic alkalosis did not have an effect on this process. The hypocapnia-mediated decrease of alveolar fluid reabsorption was associated with decreased Na,K-ATPase activity and protein abundance at the basolateral membranes of distal airspaces. The effect of low PCO2 on alveolar fluid reabsorption was reversible because clearance normalized after correcting the PCO2 back to normal levels. These data suggest that hypocapnic but not metabolic alkalosis impairs alveolar fluid reabsorption. Conceivably, correction of hypocapnic alkalosis in critically ill patients may contribute to the normalization of lung ability to clear edema. PMID:15764729
Hypocapnic but not metabolic alkalosis impairs alveolar fluid reabsorption.
Myrianthefs, Pavlos M; Briva, Arturo; Lecuona, Emilia; Dumasius, Vidas; Rutschman, David H; Ridge, Karen M; Baltopoulos, George J; Sznajder, Jacob Iasha
2005-06-01
Acid-base disturbances, such as metabolic or respiratory alkalosis, are relatively common in critically ill patients. We examined the effects of alkalosis (hypocapnic or metabolic alkalosis) on alveolar fluid reabsorption in the isolated and continuously perfused rat lung model. We found that alveolar fluid reabsorption after 1 hour was impaired by low levels of CO2 partial pressure (PCO2; 10 and 20 mm Hg) independent of pH levels (7.7 or 7.4). In addition, PCO2 higher than 30 mm Hg or metabolic alkalosis did not have an effect on this process. The hypocapnia-mediated decrease of alveolar fluid reabsorption was associated with decreased Na,K-ATPase activity and protein abundance at the basolateral membranes of distal airspaces. The effect of low PCO2 on alveolar fluid reabsorption was reversible because clearance normalized after correcting the PCO2 back to normal levels. These data suggest that hypocapnic but not metabolic alkalosis impairs alveolar fluid reabsorption. Conceivably, correction of hypocapnic alkalosis in critically ill patients may contribute to the normalization of lung ability to clear edema.
Onsurathum, Sudarat; Haonon, Ornuma; Pinlaor, Porntip; Pairojkul, Chawalit; Khuntikeo, Narong; Thanan, Raynoo; Roytrakul, Sittiruk; Pinlaor, Somchai
2018-04-01
Tumor interstitial fluid contains tumor-specific proteins that may be useful biomarkers for cancers. In this study, we identified proteins present in cholangiocarcinoma interstitial fluid. Proteins derived from three samples of tumor interstitial fluid and paired samples of adjacent normal interstitial fluid from cholangiocarcinoma patients were subjected to two-dimensional liquid chromatography with tandem mass spectrometry. Candidate proteins were selected based on a greater than twofold change in expression levels between tumor interstitial fluid and normal interstitial fluid. Upregulation of six proteins in tumor interstitial fluid, including S100 calcium binding protein A6 (S100A6), S100 calcium binding protein A9, aldo-keto reductase family 1 member C4, neuropilin-1, 14-3-3 zeta/delta, and triosephosphate isomerase was assessed by western blot and immunohistochemistry. Their potential as markers was evaluated in human cholangiocarcinoma tissue arrays, and in serum using enzyme-linked immunosorbent assay. Expression of S100A6 was higher in tumor interstitial fluid than in normal interstitial fluid and showed the highest positive rate (98.96%) in cholangiocarcinoma tissues. Serum levels of S100A6 did not differ between cholangitis and cholangiocarcinoma patients, but were significantly higher than in healthy individuals ( p < 0.0001). In cholangiocarcinoma cases, S100A6 level was associated with vascular invasion ( p = 0.007) and could distinguish cholangiocarcinoma patients from healthy individuals as effectively as the carbohydrate antigen 19-9. In addition, potential for drug treatment targeting S100A6 and other candidate proteins was also demonstrated using STITCH analysis. In conclusion, proteomics analysis of tumor interstitial fluid could be a new approach for biomarker discovery, and S100A6 is a potential risk marker for screening of cholangiocarcinoma.
Estimating Energy Consumption of Mobile Fluid Power in the United States
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lynch, Lauren; Zigler, Bradley T.
This report estimates the market size and energy consumption of mobile off-road applications utilizing hydraulic fluid power, and summarizes technology gaps and implementation barriers. Mobile fluid power is the use of hydraulic fluids under pressure to transmit power in mobile equipment applications. The mobile off-road fluid power sector includes various uses of hydraulic fluid power equipment with fundamentally diverse end-use application and operational requirements, such as a skid steer loader, a wheel loader or an agriculture tractor. The agriculture and construction segments dominate the mobile off-road fluid power market in component unit sales volume. An estimated range of energy consumedmore » by the mobile off-road fluid power sector is 0.36 - 1.8 quads per year, which was 1.3 percent - 6.5 percent of the total energy consumed in 2016 by the transportation sector. Opportunities for efficiency improvements within the fluid power system result from needs to level and reduce the peak system load requirements and develop new technologies to reduce fluid power system level losses, both of which may be facilitated by characterizing duty cycles to define standardized performance test methods. There are currently no commonly accepted standardized test methods for evaluating equipment level efficiency over a duty cycle. The off-road transportation sector currently meets criteria emissions requirements, and there are no efficiency regulations requiring original equipment manufacturers (OEM) to invest in new architecture development to improve the fuel economy of mobile off-road fluid power systems. In addition, the end-user efficiency interests are outweighed by low equipment purchase or lease price concerns, required payback periods, and reliability and durability requirements of new architecture. Current economics, low market volumes with high product diversity, and regulation compliance challenge OEM investment in commercialization of new architecture development.« less
Problems in Microgravity Fluid Mechanics: G-Jitter Convection
NASA Technical Reports Server (NTRS)
Homsy, G. M.
2005-01-01
This is the final report on our NASA grant, Problems in Microgravity Fluid Mechanics NAG3-2513: 12/14/2000 - 11/30/2003, extended through 11/30/2004. This grant was made to Stanford University and then transferred to the University of California at Santa Barbara when the PI relocated there in January 2001. Our main activity has been to conduct both experimental and theoretical studies of instabilities in fluids that are relevant to the microgravity environment, i.e. those that do not involve the action of buoyancy due to a steady gravitational field. Full details of the work accomplished under this grant are given below. Our work has focused on: (i) Theoretical and computational studies of the effect of g-jitter on instabilities of convective states where the convection is driven by forces other than buoyancy (ii) Experimental studies of instabilities during displacements of miscible fluid pairs in tubes, with a focus on the degree to which these mimic those found in immiscible fluids. (iii) Theoretical and experimental studies of the effect of time dependent electrohydrodynamic forces on chaotic advection in drops immersed in a second dielectric liquid. Our objectives are to acquire insight and understanding into microgravity fluid mechanics problems that bear on either fundamental issues or applications in fluid physics. We are interested in the response of fluids to either a fluctuating acceleration environment or to forces other than gravity that cause fluid mixing and convection. We have been active in several general areas.
NASA Astrophysics Data System (ADS)
Rahman, Md. Lutfor; Salsabil, Zaimaa; Yasmin, Nusrat; Nourin, Farah Nazifa; Ali, Mohammad
2016-07-01
This paper presents an experimental study of a closed loop Pulsating Heat Pipe (CLPHP) as the demand of smaller and effective heat transfer devices is increasing day by day. PHP is a two phase heat transfer device suited for heat transfer applications, especially suited for handling moderate to high heat fluxes in different applications. A copper made Pulsating Heat Pipe (PHP) of 250 mm length is used in this experimental work with 2 mm ID and 3 mm OD, closed end-to-end in 8 looped, evacuated and then partially filled with working fluids. The evaporation section is 50 mm, adiabatic section is 120 mm and condensation section is 80 mm. The performance characterization is done for two working fluids at Vertical (0°) orientations. The working fluids are Methanol and Ethanol and the filling ratios are 40%, 50%, 60% & 70% based on total volume, respectively. The results show that the influence of various parameters, the heat input flux, and different filling ratios on a heat transfer performance of CLPHP. Methanol shows better performance as working fluid in PHP than ethanol at present orientation for a wide range of heat inputs and can be used at high heat input conditions. Ethanol is better choice to be used in low heat input conditions.
NASA Astrophysics Data System (ADS)
Scuderi, M. M.; Collettini, C.; Marone, C.
2017-11-01
It is widely recognized that the significant increase of M > 3.0 earthquakes in Western Canada and the Central United States is related to underground fluid injection. Following injection, fluid overpressure lubricates the fault and reduces the effective normal stress that holds the fault in place, promoting slip. Although, this basic physical mechanism for earthquake triggering and fault slip is well understood, there are many open questions related to induced seismicity. Models of earthquake nucleation based on rate- and state-friction predict that fluid overpressure should stabilize fault slip rather than trigger earthquakes. To address this controversy, we conducted laboratory creep experiments to monitor fault slip evolution at constant shear stress while the effective normal stress was systematically reduced via increasing fluid pressure. We sheared layers of carbonate-bearing fault gouge in a double direct shear configuration within a true-triaxial pressure vessel. We show that fault slip evolution is controlled by the stress state acting on the fault and that fluid pressurization can trigger dynamic instability even in cases of rate strengthening friction, which should favor aseismic creep. During fluid pressurization, when shear and effective normal stresses reach the failure condition, accelerated creep occurs in association with fault dilation; further pressurization leads to an exponential acceleration with fault compaction and slip localization. Our work indicates that fault weakening induced by fluid pressurization can overcome rate strengthening friction resulting in fast acceleration and earthquake slip. Our work points to modifications of the standard model for earthquake nucleation to account for the effect of fluid overpressure and to accurately predict the seismic risk associated with fluid injection.
Horizontal insulating barriers as a way to protect groundwater
NASA Astrophysics Data System (ADS)
Cicha-Szot, Renata; Labus, Krzysztof; Falkowicz, Sławomir; Madetko, Norbert
2018-06-01
Trenchless Technology of Forming Horizontal Insulating Barriers (TFHB) can be considered a method of groundwater protection against inflow of pollutants. In TFHB technology, the working fluid (sodium silicate solution) and the gelling agent (CO2) are injected separately, using one tool, to different zones of the aquifer profile. Carbon dioxide injected into the saturation zone rises due to buoyancy forces and reaches the silicate which was injected at the water table level. This initiates the process of silicate gelation, resulting in the formation of an insulating barrier. For technological purposes, the gelation time must be controlled, and the resulting gel must have certain mechanical properties. In order to apply THFB in real conditions it was necessary to identify important technological and technical parameters, as well as to define interactions between the injected fluid and the aquifer rocks. Geochemical modelling (equilibrium, reaction path and reactive transport) was used to identify potential geochemical effects of the application of TFHB in sandy aquifers. Certain petrophysical parameters and mineralogical assemblages of aquifers were addressed, taking into account both low and strongly mineralized groundwater. The simulations revealed that TFHB does not have a negative impact on the chemistry of rock-water systems described in this work.
Proactive interference and practice effects in visuospatial working memory span task performance.
Blalock, Lisa Durrance; McCabe, David P
2011-01-01
In the current study the influence of proactive interference (PI) and practice on recall from a visuospatial working memory (WM) task was examined. Participants completed a visuospatial WM span task under either high-PI conditions (a traditional span task) or low-PI conditions (a span task with breaks between trials). Trials of each length (i.e., two to five to-be-remembered items) were equally distributed across three blocks in order to examine practice effects. Recall increased across blocks to a greater extent in the low-PI condition than in the high-PI condition, indicating that reducing PI increased recall from WM. Additionally, in the final block the correlation between fluid intelligence and WM recall was stronger for the high-PI condition than the low-PI condition, indicating that practice reduced the strength of the correlation between span task recall and fluid intelligence, but only in the low-PI condition. These results support current theories that propose that one source of variability in recall from WM span task is the build-up of PI, and that PI build-up is an important contributing factor to the relation between visuospatial WM span task recall and higher-level cognition.
Effect of asynchrony on numerical simulations of fluid flow phenomena
NASA Astrophysics Data System (ADS)
Konduri, Aditya; Mahoney, Bryan; Donzis, Diego
2015-11-01
Designing scalable CFD codes on massively parallel computers is a challenge. This is mainly due to the large number of communications between processing elements (PEs) and their synchronization, leading to idling of PEs. Indeed, communication will likely be the bottleneck in the scalability of codes on Exascale machines. Our recent work on asynchronous computing for PDEs based on finite-differences has shown that it is possible to relax synchronization between PEs at a mathematical level. Computations then proceed regardless of the status of communication, reducing the idle time of PEs and improving the scalability. However, accuracy of the schemes is greatly affected. We have proposed asynchrony-tolerant (AT) schemes to address this issue. In this work, we study the effect of asynchrony on the solution of fluid flow problems using standard and AT schemes. We show that asynchrony creates additional scales with low energy content. The specific wavenumbers affected can be shown to be due to two distinct effects: the randomness in the arrival of messages and the corresponding switching between schemes. Understanding these errors allow us to effectively control them, rendering the method's feasibility in solving turbulent flows at realistic conditions on future computing systems.
NASA Astrophysics Data System (ADS)
Pintoro, A.; Ambarita, H.; Nur, T. B.; Napitupulu, F. H.
2018-02-01
Indonesia has a high potential energy resources from geothermal activities. Base on the report of Asian Development Bank and World Bank, the estimated of Indonesian hydrothermal geothermal resource considered to be the largest among the world. If it’s can be utilized to produce the electric power, it’s can contribute to increasing the electrification rates in Indonesia. In this study, an experimental studied of electric power generation, utilizing the Organic Rankine Cycle (ORC) system to convert the low level heat of hydrothermal as an energy source. The temperature of hydrothermal was modelled as hot water from water boiler which has a temperature range from 60 °C - 100 °C to heat up the organic working fluid of ORC system. The system can generated 1,337.7 watts of electricity when operated using R134A with hot water inlet temperature of 100 °C. Changing system working fluid to R245fa, the net power obtained increase to 1,908.9 watts with the same heat source condition. This study showed that the ORC system can be implemented to utilize low temperature heat source of hydrothermal in Indonesia.
Engineered diamond nanopillars as mobile probes for high sensitivity metrology in fluid
NASA Astrophysics Data System (ADS)
Andrich, P.; de Las Casas, C. F.; Heremans, F. J.; Awschalom, D. D.; Aleman, B. J.; Ohno, K.; Lee, J. C.; Hu, E. L.
2015-03-01
The nitrogen-vacancy (NV) center`s optical addressability and exceptional spin coherence properties at room temperature, along with diamond`s biocompatibility, has put this defect at the frontier of metrology applications in biological environments. To push the spatial resolution to the nanoscale, extensive research efforts focus on using NV centers embedded in nanodiamonds (NDs). However, this approach has been hindered by degraded spin coherence properties in NDs and the lack of a platform for spatial control of the nanoparticles in fluid. In this work, we combine the use of high quality diamond membranes with a top-down patterning technique to fabricate diamond nanoparticles with engineered and highly reproducible shape, size, and NV center density. We obtain NDs, easily releasable from the substrate into a water suspension, which contain single NV centers exhibiting consistently long spin coherence times (up to 700 μs). Additionally, we demonstrate highly stable, three-dimensional optical trapping of the nanoparticles within a microfluidic circuit. This level of control enables a bulk-like DC magnetic sensitivity and gives access to dynamical decoupling techniques on contactless, miniaturized diamond probes. This work was supported by DARPA, AFOSR, and the DIAMANT program.
Vapor bubble evolution on a heated surface containing open microchannels
NASA Astrophysics Data System (ADS)
Forster, Christopher J.; Glezer, Ari; Smith, Marc K.
2011-11-01
Power electronics require cooling technologies capable of high heat fluxes at or below the operating temperatures of these devices. Boiling heat transfer is an effective choice for such cooling, but it is limited by the critical heat flux (CHF), which is typically near 125 W/cm2 for pool boiling of water on a flat plate at standard pressure and gravity. One method of increasing CHF is to incorporate an array of microchannels into the heated surface. Microchannels have been experimentally shown to improve CHF, and the goal of this study is to determine the primary mechanisms associated with the microchannels that allow for the increased CHF. While the use of various microstructures is not new, the emphasis of previous work has been on heat transfer aspects, as opposed to the fluid dynamics inside and in the vicinity of the microchannels. This work considers the non-isothermal fluid motion during bubble growth and departure by varying channel geometry, spacing, and heat flux input using a level-set method including vaporization and condensation. These results and the study of the underlying mechanisms will aid in the design optimization of microchannel-based cooling devices. Supported by ONR.
NAMRU-3 Reprint Accession List 1981. Number 11.
1982-01-01
75-99, 1981. 12JO KANSOUR, •.M., GUINDI, S. and GIRGIS, N.I.: Levels of Individual Serum and Cerebrospinal Fluid Proteins in Purulent and Tuberculous ...2):134-139, i981. 1249 EL NAGGAR, A. and HIGASHI, G.I.: Tuberculous Meningitis: E-rosette-forming T Lymphocytes in Cerebrospinal Fluid. Neurology (Ny...Levels Serum and Cerebrospinal Fluid Proteins in Purulent and Tuberculous Meningitis 1240 CHEMOTHERAPY * Effect of Niradozole Therapy in Children *with
Fluid Dynamics and Solidification of Molten Solder Droplets Impacting on a Substrate in Microgravity
NASA Technical Reports Server (NTRS)
Megardis, C. M.; Poulikakos, D.; Diversiev, G.; Boomsma, K.; Xiong, B.; Nayagam, V.
1999-01-01
This program investigates the fluid dynamics and simultaneous solidification of molten solder droplets impacting on a flat smooth substrate. The problem of interest is directly relevant to the printing of microscopic solder droplets in surface mounting of microelectronic devices. The study consists of a theoretical and an experimental component. The theoretical work uses axisymmetric Navier-Stokes models based on finite element techniques. The experimental work will be ultimately performed in microgravity in order to allow for the use of larger solder droplets which make feasible the performance of accurate measurements, while maintaining similitude of the relevant fluid dynamics groups (Re, We).
Fluid Dynamics and Solidification of Molten Solder Droplets Impacting on a Substrate in Microgravity
NASA Technical Reports Server (NTRS)
Poulikakos, Dimos; Megaridis, Constantine M.; Vedha-Nayagam, M.
1996-01-01
This program investigates the fluid dynamics and simultaneous solidification of molten solder droplets impacting on a flat substrate. The problem of interest is directly relevant to the printing of microscopic solder droplets in surface mounting of microelectronic devices. The study consists of a theoretical and an experimental component. The theoretical work uses axisymmetric Navier-Stokes models based on finite element techniques. The experimental work is performed in microgravity to allow for the use of larger solder droplets that make feasible the performance of accurate measurements while maintaining similitude of the relevant fluid dynamics groups (Re, We) and keeping the effect of gravity negligible.
Viscosity and non-Newtonian features of thickened fluids used for dysphagia therapy.
O'Leary, Mark; Hanson, Ben; Smith, Christina
2010-08-01
Thickening agents based primarily on granulated maize starch are widely used in the care of patients with swallowing difficulties, increasing viscosity of consumed fluids. This slows bolus flow during swallowing, allowing airway protection to be more properly engaged. Thickened fluids have been shown to exhibit time-varying behavior and are non-Newtonian, complicating assessment of fluid thickness, potentially compromising efficacy of therapy. This work aimed to quantify the flow properties of fluids produced with commercial thickeners at shear rates representative of slow tipping in a beaker to fast swallowing. Results were presented as indices calculated using a power-law model representing apparent viscosity (consistency index) and non-Newtonian nature of flow (flow behavior index). Immediately following mixing, 3 fluid thicknesses showed distinct consistency indices and decreasing flow behavior index with increasing thickener concentration. An increase in consistency index over 30 min was observed, but only for samples that were repeatedly sheared during acquisition. Three-hour measurements showed changes in consistency index across fluids with the largest being a 25% rise from initial value. This may have implications for efficacy of treatment, as fluids are not always consumed immediately upon mixing. Flow behavior indices were comparable across thickeners exhibiting similar rises over time. The indices were a more complete method of quantifying flow properties compared with single viscosity measurements, allowing an increased depth of analysis. The non-Newtonian nature of fluids perhaps renders them particularly suitable for use as dysphagia therapies, and such analysis may allow the possibility of altering these properties to optimize therapeutic efficacy to be explored. Practical Application: Effective treatment of swallowing disorders relies upon the appropriate choice and subsequent reproduction of drinks thickened to one of a number of predetermined levels. Currently there are no agreed methods of measuring the thickness of these drinks in use and the specifications are subjective, relying on descriptions such as "syrup" thick. This research aims to further understanding of the flow properties of thickened drinks and bring a quantified measure of thickness closer to being a practical reality.
Jungheim, Emily S; Macones, George A; Odem, Randall R; Patterson, Bruce W; Lanzendorf, Susan E; Ratts, Valerie S; Moley, Kelle H
2011-05-01
To determine if follicular free fatty acid (FFA) levels are associated with cumulus oocyte complex (COC) morphology. Prospective cohort study. University in vitro fertilization (IVF) practice. A total of 102 women undergoing IVF. Measurement of FFAs in serum and ovarian follicular fluid. Total and specific follicular and serum FFA levels, correlations between follicular and serum FFAs, and associations between follicular FFA levels and markers of oocyte quality, including COC morphology. Predominant follicular fluid and serum FFAs were oleic, palmitic, linoleic, and stearic acids. Correlations between follicular and serum FFA concentrations were weak (r=0.252, 0.288, 0.236, 0.309, respectively for specific FFAs; r=0.212 for total FFAs). A receiver operating characteristic curve determined total follicular FFAs≥0.232 μmol/mL distinguished women with a lower versus higher percentage of COCs with favorable morphology. Women with elevated follicular FFAs (n=31) were more likely to have COCs with poor morphology than others (n=71; OR 3.3, 95% CI1.2-9.2). This relationship held after adjusting for potential confounders, including age, body mass index, endometriosis, and amount of gonadotropin administered (β=1.2; OR 3.4, 95% CI 1.1-10.4). Elevated follicular FFA levels are associated with poor COC morphology. Further work is needed to determine what factors influence follicular FFA levels and if these factors impact fertility. Copyright © 2011 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.
An On-Chip Disposable Salivary Glucose Sensor for Diabetes Control.
Du, Yunqing; Zhang, Wenjun; Wang, Ming L
2016-11-01
Self-management of blood glucose (BG) is considered a norm for diabetes control. However, this invasive process is uncomfortable for patients, especially when intensive measurements with frequent finger pricks are required. Saliva, an alternative body fluid that is easily accessible and contains trace amount of glucose can be potentially used for the noninvasive monitoring of diabetes. As a solution for real-time glucose measurements using saliva for diabetic care, we have developed an on-chip disposable glucose nano-biosensor through a layer-by-layer assembly process. In this work, a clinical study of 10 healthy subjects was conducted to determine the potential usefulness of salivary glucose (SG) sensors for glycemic control. Findings revealed (1) the individual BG/SG ratio at fasting was consistent over an entire year when there was no significant change of personal health; (2) the individual SG levels tracked closely with BG levels after meals; (3) a time difference of 15-30 minutes exists between peak levels of BG and SG; (4) 2 hours after a meal, the BG/SG ratio returned to a similar value at fasting. We propose to measure fasting and pre- and 2-hour postprandial SG levels for self-management of glycemic levels. As a result, this article is not intended to replace the common BG tests. With preliminary results, we believe SG itself could be used as means for reliable diabetes monitoring and a potential fluid for prognosis of future disease. © 2016 Diabetes Technology Society.
Rose, Nathan S
2013-12-01
Individual differences in working memory (WM) are related to performance on secondary memory (SM), and fluid intelligence (gF) tests. However, the source of the relation remains unclear, in part because few studies have controlled for the nature of encoding; therefore, it is unclear whether individual variation is due to encoding, maintenance, or retrieval processes. In the current study, participants performed a WM task (the levels-of-processing span task; Rose, Myerson, Roediger III, & Hale, 2010) and a SM test that tested for both targets and the distracting processing words from the initial WM task. Deeper levels of processing at encoding did not benefit WM, but did benefit subsequent SM, although the amount of benefit was smaller for those with lower WM spans. This result suggests that, despite encoding cues that facilitate retrieval from SM, low spans may have engaged in shallower, maintenance-focused processing to maintain the words in WM. Low spans also recalled fewer targets, more distractors, and more extralist intrusions than high spans, although this was partially due to low spans' poorer recall of targets, which resulted in a greater number of opportunities to commit recall errors. Delayed recall of intrusions and commission of source errors (labeling targets as processing words and vice versa) were significant negative predictors of gF. These results suggest that the ability to use source information to recall relevant information and withhold recall of irrelevant information is a critical source of both individual variation in WM and the relation between WM, SM, and gF. (PsycINFO Database Record (c) 2013 APA, all rights reserved).
Entropy of level-cut random Gaussian structures at different volume fractions
NASA Astrophysics Data System (ADS)
Marčelja, Stjepan
2017-10-01
Cutting random Gaussian fields at a given level can create a variety of morphologically different two- or several-phase structures that have often been used to describe physical systems. The entropy of such structures depends on the covariance function of the generating Gaussian random field, which in turn depends on its spectral density. But the entropy of level-cut structures also depends on the volume fractions of different phases, which is determined by the selection of the cutting level. This dependence has been neglected in earlier work. We evaluate the entropy of several lattice models to show that, even in the cases of strongly coupled systems, the dependence of the entropy of level-cut structures on molar fractions of the constituents scales with the simple ideal noninteracting system formula. In the last section, we discuss the application of the results to binary or ternary fluids and microemulsions.
Free-piston regenerative hot gas hydraulic engine
NASA Technical Reports Server (NTRS)
Beremand, D. G. (Inventor)
1980-01-01
A displacer piston which is driven pneumatically by a high-pressure or low-pressure gas is included in a free-piston regenerative hydraulic engine. Actuation of the displacer piston circulates the working fluid through a heater, a regenerator and a cooler. The present invention includes an inertial mass such as a piston or a hydraulic fluid column to effectively store and supply energy during portions of the cycle. Power is transmitted from the working fluid to a hydraulic fluid across a diaphragm or lightweight piston to achieve a hydraulic power out-put. The displacer piston of the present invention may be driven pneumatically, hydraulically or electromagnetically. In addition, the displacer piston and the inertial mass of the present invention may be positioned on the same side of the diaphragm member or may be separated by the diaphragm member.
Contextual analysis of fluid intelligence.
Salthouse, Timothy A; Pink, Jeffrey E; Tucker-Drob, Elliot M
2008-01-01
The nature of fluid intelligence was investigated by identifying variables that were, and were not, significantly related to this construct. Relevant information was obtained from three sources: re-analyses of data from previous studies, a study in which 791 adults performed storage-plus-processing working memory tasks, and a study in which 236 adults performed a variety of working memory, updating, and cognitive control tasks. The results suggest that fluid intelligence represents a broad individual difference dimension contributing to diverse types of controlled or effortful processing. The analyses also revealed that very few of the age-related effects on the target variables were statistically independent of effects on established cognitive abilities, which suggests most of the age-related influences on a wide variety of cognitive control variables overlap with age-related influences on cognitive abilities such as fluid intelligence, episodic memory, and perceptual speed.
Waste heat recovery system for recapturing energy after engine aftertreatment systems
Ernst, Timothy C.; Nelson, Christopher R.
2014-06-17
The disclosure provides a waste heat recovery (WHR) system including a Rankine cycle (RC) subsystem for converting heat of exhaust gas from an internal combustion engine, and an internal combustion engine including the same. The WHR system includes an exhaust gas heat exchanger that is fluidly coupled downstream of an exhaust aftertreatment system and is adapted to transfer heat from the exhaust gas to a working fluid of the RC subsystem. An energy conversion device is fluidly coupled to the exhaust gas heat exchanger and is adapted to receive the vaporized working fluid and convert the energy of the transferred heat. The WHR system includes a control module adapted to control at least one parameter of the RC subsystem based on a detected aftertreatment event of a predetermined thermal management strategy of the aftertreatment system.
The subscale orbital fluid transfer experiment
NASA Technical Reports Server (NTRS)
Meserole, J. S.; Collins, Frank G.; Jones, Ogden; Antar, Basil; Menzel, Reinhard; Gray, Perry
1995-01-01
The work during the present year consisted of examining concepts for visual observation of the fluid transfer process, examination of methods for accurately metering the amount of liquid transferred between the two tanks, examination of possible test fluids, and consideration of the materials to use for the elastomeric diaphragm. The objective of the visual observation is to locate the fluid-vapor interfaces and, if possible, quantify the amount of vapor and the area of the interface. It is proposed to use video cameras to view the overall process in each tank and to place borescopes or other devices through the tank walls to obtain detailed, undistorted views inside the tanks of critical portions of the transfer process. Further work will continue to find an economical means for providing this detailed view, which clearly would increase the data obtained from the experiment.
Techniques to derive geometries for image-based Eulerian computations
Dillard, Seth; Buchholz, James; Vigmostad, Sarah; Kim, Hyunggun; Udaykumar, H.S.
2014-01-01
Purpose The performance of three frequently used level set-based segmentation methods is examined for the purpose of defining features and boundary conditions for image-based Eulerian fluid and solid mechanics models. The focus of the evaluation is to identify an approach that produces the best geometric representation from a computational fluid/solid modeling point of view. In particular, extraction of geometries from a wide variety of imaging modalities and noise intensities, to supply to an immersed boundary approach, is targeted. Design/methodology/approach Two- and three-dimensional images, acquired from optical, X-ray CT, and ultrasound imaging modalities, are segmented with active contours, k-means, and adaptive clustering methods. Segmentation contours are converted to level sets and smoothed as necessary for use in fluid/solid simulations. Results produced by the three approaches are compared visually and with contrast ratio, signal-to-noise ratio, and contrast-to-noise ratio measures. Findings While the active contours method possesses built-in smoothing and regularization and produces continuous contours, the clustering methods (k-means and adaptive clustering) produce discrete (pixelated) contours that require smoothing using speckle-reducing anisotropic diffusion (SRAD). Thus, for images with high contrast and low to moderate noise, active contours are generally preferable. However, adaptive clustering is found to be far superior to the other two methods for images possessing high levels of noise and global intensity variations, due to its more sophisticated use of local pixel/voxel intensity statistics. Originality/value It is often difficult to know a priori which segmentation will perform best for a given image type, particularly when geometric modeling is the ultimate goal. This work offers insight to the algorithm selection process, as well as outlining a practical framework for generating useful geometric surfaces in an Eulerian setting. PMID:25750470
Badawy, Mahmoud A; Kamel, Amany O; Sammour, Omaima A
2016-01-01
The purpose of this work is to use biorelevant media to evaluate the robustness of a poorly water soluble weakly basic drug to variations along the gastrointestinal tract (GIT) after incorporation in liquisolid compacts and to assess the success of these models in predicting the in vivo performance. Liquisolid tablets were prepared using mosapride citrate as a model drug. A factorial design experiment was used to study the effect of three factors, namely: drug concentration at two levels (5% and 10%), carriers at three levels (avicel, mannitol and lactose) and powder excipients ratio (R) of the coating material at two levels (25 and 30). The in vitro dissolution media utilized were 0.1 N HCl, hypoacidic stomach model and a transfer model simulating the transfer from the stomach to the intestine. All compacts released above 95% of drug after 10 min in 0.1 N HCl. In the hypoacidic model, the compacts with R 30 were superior compared to R 25, where they released >90% of drug after 10 min compared to 80% for R 25. After the transfer of the optimum compacts from Simulated gastric fluid fast (SGFfast) to fasted state simulated intestinal fluid, slight turbidity appeared after 30 min, and the amount of drug dissolved slightly decreased from 96.91% to 90.59%. However, after the transfer from SGFfast to fed state simulated intestinal fluid, no turbidity or precipitation occurred throughout time of the test (60 min). In vivo pharmacokinetic study in human volunteers proved the success of the in vitro models with enhancement of the oral bioavailability (121.20%) compared to the commercial product.
A Novel Approach for Modeling Chemical Reaction in Generalized Fluid System Simulation Program
NASA Technical Reports Server (NTRS)
Sozen, Mehmet; Majumdar, Alok
2002-01-01
The Generalized Fluid System Simulation Program (GFSSP) is a computer code developed at NASA Marshall Space Flight Center for analyzing steady state and transient flow rates, pressures, temperatures, and concentrations in a complex flow network. The code, which performs system level simulation, can handle compressible and incompressible flows as well as phase change and mixture thermodynamics. Thermodynamic and thermophysical property programs, GASP, WASP and GASPAK provide the necessary data for fluids such as helium, methane, neon, nitrogen, carbon monoxide, oxygen, argon, carbon dioxide, fluorine, hydrogen, water, a hydrogen, isobutane, butane, deuterium, ethane, ethylene, hydrogen sulfide, krypton, propane, xenon, several refrigerants, nitrogen trifluoride and ammonia. The program which was developed out of need for an easy to use system level simulation tool for complex flow networks, has been used for the following purposes to name a few: Space Shuttle Main Engine (SSME) High Pressure Oxidizer Turbopump Secondary Flow Circuits, Axial Thrust Balance of the Fastrac Engine Turbopump, Pressurized Propellant Feed System for the Propulsion Test Article at Stennis Space Center, X-34 Main Propulsion System, X-33 Reaction Control System and Thermal Protection System, and International Space Station Environmental Control and Life Support System design. There has been an increasing demand for implementing a combustion simulation capability into GFSSP in order to increase its system level simulation capability of a liquid rocket propulsion system starting from the propellant tanks up to the thruster nozzle for spacecraft as well as launch vehicles. The present work was undertaken for addressing this need. The chemical equilibrium equations derived from the second law of thermodynamics and the energy conservation equation derived from the first law of thermodynamics are solved simultaneously by a Newton-Raphson method. The numerical scheme was implemented as a User Subroutine in GFSSP.
Application of a magnetic fluid seal to rotary blood pumps
NASA Astrophysics Data System (ADS)
Mitamura, Y.; Arioka, S.; Sakota, D.; Sekine, K.; Azegami, M.
2008-05-01
A magnetic fluid seal enables mechanical contact-free rotation of a shaft without frictional heat and material wear and hence has excellent durability. However, the durability of a magnetic fluid seal decreases in liquid. The life of a seal applied to a rotary blood pump is not known. We have developed a magnetic fluid seal that has a shield mechanism minimizing the influence of the rotary pump on the magnetic fluid. The developed magnetic fluid seal worked for over 286 days in a continuous flow condition, for 24 days (on-going) in a pulsatile flow condition and for 24 h (electively terminated) in blood flow. The magnetic fluid seal is promising as a shaft seal for rotary blood pumps.
Application of a magnetic fluid seal to rotary blood pumps.
Mitamura, Y; Arioka, S; Sakota, D; Sekine, K; Azegami, M
2008-05-21
A magnetic fluid seal enables mechanical contact-free rotation of a shaft without frictional heat and material wear and hence has excellent durability. However, the durability of a magnetic fluid seal decreases in liquid. The life of a seal applied to a rotary blood pump is not known. We have developed a magnetic fluid seal that has a shield mechanism minimizing the influence of the rotary pump on the magnetic fluid. The developed magnetic fluid seal worked for over 286 days in a continuous flow condition, for 24 days (on-going) in a pulsatile flow condition and for 24 h (electively terminated) in blood flow. The magnetic fluid seal is promising as a shaft seal for rotary blood pumps.
Towards a sharp-interface volume-of-fluid methodology for modeling evaporation
NASA Astrophysics Data System (ADS)
Pathak, Ashish; Raessi, Mehdi
2017-11-01
In modeling evaporation, the diffuse-interface (one-domain) formulation yields inaccurate results. Recent efforts approaching the problem via a sharp-interface (two-domain) formulation have shown significant improvements. The reasons behind their better performance are discussed in the present work. All available sharp-interface methods, however, exclusively employ the level-set. In the present work, we develop a sharp-interface evaporation model in a volume-of-fluid (VOF) framework in order to leverage its mass-conserving property as well as its ability to handle large topographical changes. We start with a critical review of the assumptions underlying the mathematical equations governing evaporation. For example, it is shown that the assumption of incompressibility can only be applied in special circumstances. The famous D2 law used for benchmarking is valid exclusively to steady-state test problems. Transient is present over significant lifetime of a micron-size droplet. Therefore, a 1D spherical fully transient model is developed to provide a benchmark transient solution. Finally, a 3D Cartesian Navier-Stokes evaporation solver is developed. Some preliminary validation test-cases are presented for static and moving drop evaporation. This material is based upon work supported by the Department of Energy, Office of Energy Efficiency and Renewable Energy and the Department of Defense, Tank and Automotive Research, Development, and Engineering Center, under Award Number DEEE0007292.
Turner, Mark J.; Saint‐Criq, Vinciane; Patel, Waseema; Ibrahim, Salam H.; Verdon, Bernard; Ward, Christopher; Garnett, James P.; Tarran, Robert; Cann, Martin J.
2015-01-01
Key points Raised arterial blood CO2 (hypercapnia) is a feature of many lung diseases.CO2 has been shown to act as a cell signalling molecule in human cells, notably by influencing the levels of cell signalling second messengers: cAMP and Ca2+.Hypercapnia reduced cAMP‐stimulated cystic fibrosis transmembrane conductance regulator‐dependent anion and fluid transport in Calu‐3 cells and primary human airway epithelia but did not affect cAMP‐regulated HCO3 − transport via pendrin or Na+/HCO3 − cotransporters.These results further support the role of CO2 as a cell signalling molecule and suggests CO2‐induced reductions in airway anion and fluid transport may impair innate defence mechanisms of the lungs. Abstract Hypercapnia is clinically defined as an arterial blood partial pressure of CO2 of above 40 mmHg and is a feature of chronic lung disease. In previous studies we have demonstrated that hypercapnia modulates agonist‐stimulated cAMP levels through effects on transmembrane adenylyl cyclase activity. In the airways, cAMP is known to regulate cystic fibrosis transmembrane conductance regulator (CFTR)‐mediated anion and fluid secretion, which contributes to airway surface liquid homeostasis. The aim of the current work was to investigate if hypercapnia could modulate cAMP‐regulated ion and fluid transport in human airway epithelial cells. We found that acute exposure to hypercapnia significantly reduced forskolin‐stimulated elevations in intracellular cAMP as well as both adenosine‐ and forskolin‐stimulated increases in CFTR‐dependent transepithelial short‐circuit current, in polarised cultures of Calu‐3 human airway cells. This CO2‐induced reduction in anion secretion was not due to a decrease in HCO3 − transport given that neither a change in CFTR‐dependent HCO3 − efflux nor Na+/HCO3 − cotransporter‐dependent HCO3 − influx were CO2‐sensitive. Hypercapnia also reduced the volume of forskolin‐stimulated fluid secretion over 24 h, yet had no effect on the HCO3 − content of the secreted fluid. Our data reveal that hypercapnia reduces CFTR‐dependent, electrogenic Cl− and fluid secretion, but not CFTR‐dependent HCO3 − secretion, which highlights a differential sensitivity of Cl− and HCO3 − transporters to raised CO2 in Calu‐3 cells. Hypercapnia also reduced forskolin‐stimulated CFTR‐dependent anion secretion in primary human airway epithelia. Based on current models of airways biology, a reduction in fluid secretion, associated with hypercapnia, would be predicted to have important consequences for airways hydration and the innate defence mechanisms of the lungs. PMID:26574187
Effect of evaporation and condensation on a thermoacoustic engine: A Lagrangian simulation approach.
Yasui, Kyuichi; Izu, Noriya
2017-06-01
Acoustic oscillations of a fluid (a mixture of gas and vapor) parcel in a wet stack of a thermoacoustic engine are numerically simulated with a Lagrangian approach taking into account Rott equations and the effect of non-equilibrium evaporation and condensation of water vapor at the stack surface. In a traveling-wave engine, the volume oscillation amplitude of a fluid parcel always increases by evaporation and condensation. As a result, pV work done by a fluid parcel is enhanced, which means enhancement of acoustic energy in a thermoacoustic engine. On the other hand, in a standing-wave engine, the volume oscillation amplitude sometimes decreases by evaporation and condensation, and pV work is suppressed. Presence of a tiny traveling-wave component, however, results in the enhancement of pV work by evaporation and condensation.
Dual manifold heat pipe evaporator
Adkins, D.R.; Rawlinson, K.S.
1994-01-04
An improved evaporator section is described for a dual manifold heat pipe. Both the upper and lower manifolds can have surfaces exposed to the heat source which evaporate the working fluid. The tubes in the tube bank between the manifolds have openings in their lower extensions into the lower manifold to provide for the transport of evaporated working fluid from the lower manifold into the tubes and from there on into the upper manifold and on to the condenser portion of the heat pipe. A wick structure lining the inner walls of the evaporator tubes extends into both the upper and lower manifolds. At least some of the tubes also have overflow tubes contained within them to carry condensed working fluid from the upper manifold to pass to the lower without spilling down the inside walls of the tubes. 1 figure.
Development of Electric Power Units Driven by Waste Heat
NASA Astrophysics Data System (ADS)
Inoue, Naoyuki; Takeuchi, Takao; Kaneko, Atsushi; Uchimura, Tomoyuki; Irie, Kiichi; Watanabe, Hiroyoshi
For the development of a simple and compact power generator driven by waste heat, working fluids and an expander were studied, then a practical electric power unit was put to test. Many working fluids were calculated with the low temperature power cycle (evaporated at 77°C, condensed at 42°C),and TFE,R123,R245fa were selected to be suitable for the cycle. TFE(Trifluoroethanol CF3CH2OH) was adopted to the actual power generator which was tested. A radial turbine was adopted as an expander, and was newly designed and manufactured for working fluid TFE. The equipment was driven by hot water as heat source and cooling water as cooling source, and generated power was connected with electric utility. Characteristics of the power generating cycle and characteristics of the turbine were obtained experimentally.
Shangguan, Fangfang; Shi, Jiannong
2009-08-01
Sex hormone such as testosterone was recently recognized as an important contributor of spatial cognition and intelligence during development, but the relationship between puberty timing and intelligence especially in children is largely unknown. Here in this study, we investigated the potential relationship between the level of sex hormones in saliva and fluid intelligence in 8- to 12-year-old Chinese boys. Fluid intelligence was measured by the Cattell's Culture Fair Intelligence Test. 1600 children aged 8-12 years were included in the Cattell's Culture Fair Intelligence Test and saliva samples were collected thereafter from 166 boys with normal intelligence distribution, composed of 49, 54 and 63 boys in 8-, 10- and 12-year-old group respectively. The level of salivary testosterone and estradiol was measured with enzyme-immunoassay technique. Data of BMI and age were collected. The relationship between the level of salivary sex hormones and fluid intelligence was analysed by correlation test. There was no significant correlation between salivary testosterone level and fluid intelligence in 8-year-old boys, whereas there was a significant positive correlation in 10-year-old boys and a significant negative correlation in 12-year-old boys between those two variable. To verify the correlation, we performed stepwise multivariate linear regression and discriminant analysis, with both the age and BMI of the boys and their parents, and salivary estradiol level considered. The results showed that the level of testosterone and intelligence was correlated, and the correlation was much stronger when the level of salivary testosterone was higher than 14 pg/ml. In summary, the study suggests that the relationship of testosterone and intelligence varies from late childhood to early adolescence, and the puberty timing is closely related with fluid intelligence.
Fadda, S M H; Bassyouni, I H; Khalifa, R H; Elsaid, N Y
2018-05-01
Few studies have reported a possible involvement of pleiotrophin (PTN) in the pathophysiology of osteoarthritis (OA) and very little is known about its role in rheumatoid arthritis (RA). This study is to measure PTN in the sera and synovial fluids in RA and OA and to assess its relation to activity, functional class and radiological staging. Serum and synovial fluid samples were collected from 35 RA patients and 40 knee OA patients and serum samples were withdrawn from 20 healthy controls. Demographic, clinical and serological data were prospectively assessed. Functional and radiographic grades were also assessed. Serum and synovial fluid PTN levels were measured using enzyme-linked immunosorbent assay (ELISA). There was no statistical significant differences (p > 0.05) on comparing the mean PTN level in sera of RA, OA patients and healthy controls. However the mean synovial fluid level of PTN in both patient groups was significantly higher than mean serum level (p < 0.001). Significant correlations between the serum PTN level and both morning stiffness duration (p = 0.008) and mHAQ score (p = 0.039) were only observed in RA patients. Our results point to a possible important role of PTN in RA and OA. We firstly report a serological pattern of PTN in the sera and synovial fluids of RA patients. However its implementation as a disease marker or a potential target therapy in both diseases awaits larger studies and further investigations.
Borgquist, Ola; Ingemansson, Richard; Malmsjö, Malin
2011-02-01
Negative-pressure wound therapy promotes healing by drainage of excessive fluid and debris and by mechanical deformation of the wound. The most commonly used negative pressure, -125 mmHg, may cause pain and ischemia, and the pressure often needs to be reduced. The aim of the present study was to examine wound contraction and fluid removal at different levels of negative pressure. Peripheral wounds were created in 70-kg pigs. The immediate effects of negative-pressure wound therapy (-10 to -175 mmHg) on wound contraction and fluid removal were studied in eight pigs. The long-term effects on wound contraction were studied in eight additional pigs during 72 hours of negative-pressure wound therapy at -75 mmHg. Wound contraction and fluid removal increased gradually with increasing levels of negative pressure until reaching a steady state. Maximum wound contraction was observed at -75 mmHg. When negative-pressure wound therapy was discontinued, after 72 hours of therapy, the wound surface area was smaller than before therapy. Maximum wound fluid removal was observed at -125 mmHg. Negative-pressure wound therapy facilitates drainage of wound fluid and exudates and results in mechanical deformation of the wound edge tissue, which is known to stimulate granulation tissue formation. Maximum wound contraction is achieved already at -75 mmHg, and this may be a suitable pressure for most wounds. In wounds with large volumes of exudate, higher pressure levels may be needed for the initial treatment period.
... infection. IV fluids are also given to prevent dehydration. Much of the body's fluid is lost through open skin. Moist compresses ... result include: Abnormal level of fluids in the body causing ... or electrolyte imbalance Poor temperature control (in young ...
Analysis and control of the METC fluid bed gasifier. Quarterly progress report, January--March 1995
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1995-03-01
This document summarizes work performed for the period 10/1/94 to 3/31/95. In this work, three components will form the basis for design of a control scheme for the Fluidized Bed Gasifier (FBG) at METC: (1) a control systems analysis based on simple linear models derived from process data, (2) review of the literature on fluid bed gasifier operation and control, and (3) understanding of present FBG operation and real world considerations. Below we summarize work accomplished to data in each of these areas.
Rebound and jet formation of a fluid-filled sphere
NASA Astrophysics Data System (ADS)
Killian, Taylor W.; Klaus, Robert A.; Truscott, Tadd T.
2012-12-01
This study investigates the impact dynamics of hollow elastic spheres partially filled with fluid. Unlike an empty sphere, the internal fluid mitigates some of the rebound through an impulse driven exchange of energy wherein the fluid forms a jet inside the sphere. Surprisingly, this occurs on the second rebound or when the free surface is initially perturbed. Images gathered through experimentation show that the fluid reacts more quickly to the impact than the sphere, which decouples the two masses (fluid and sphere), imparts energy to the fluid, and removes rebound energy from the sphere. The experimental results are analyzed in terms of acceleration, momentum and an energy method suggesting an optimal fill volume in the neighborhood of 30%. While the characteristics of the fluid (i.e., density, viscosity, etc.) affect the fluid motion (i.e., type and size of jet formation), the rebound characteristics remain similar for a given fluid volume independent of fluid type. Implications of this work are a potential use of similar passive damping systems in sports technology and marine engineering.
Evaporative cooler including one or more rotating cooler louvers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gerlach, David W
An evaporative cooler may include an evaporative cooler housing with a duct extending therethrough, a plurality of cooler louvers with respective porous evaporative cooler pads, and a working fluid source conduit. The cooler louvers are arranged within the duct and rotatably connected to the cooler housing along respective louver axes. The source conduit provides an evaporative cooler working fluid to the cooler pads during at least one mode of operation.
Concentrated solar power generation using solar receivers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anderson, Bruce N.; Treece, William Dean; Brown, Dan
Inventive concentrated solar power systems using solar receivers, and related devices and methods, are generally described. Low pressure solar receivers are provided that function to convert solar radiation energy to thermal energy of a working fluid, e.g., a working fluid of a power generation or thermal storage system. In some embodiments, low pressure solar receivers are provided herein that are useful in conjunction with gas turbine based power generation systems.
Effect of nanofluid concentration on two-phase thermosyphon heat exchanger performance
NASA Astrophysics Data System (ADS)
Cieśliński, Janusz T.
2016-06-01
An approach - relaying on application of nanofluid as a working fluid, to improve performance of the two-phase thermosyphon heat exchanger (TPTHEx) has been proposed. The prototype heat exchanger consists of two horizontal cylindrical vessels connected by two risers and a downcomer. Tube bundles placed in the lower and upper cylinders work as an evaporator and a condenser, respectively. Distilled water and nanofluid water-Al2O3 solution were used as working fluids. Nanoparticles were tested at the concentration of 0.01% and 0.1% by weight. A modified Peclet equation and Wilson method were used to estimate the overall heat transfer coefficient of the tested TPTHEx. The obtained results indicate better performance of the TPTHEx with nanofluids as working fluid compared to distilled water, independent of nanoparticle concentration tested. However, increase in nanoparticle concentration results in overall heat transfer coefficient decrease of the TPTHEx examined. It has been observed that, independent of nanoparticle concentration tested, decrease in operating pressure results in evaporation heat transfer coefficient increase.
Do the effects of working memory training depend on baseline ability level?
Foster, Jeffrey L; Harrison, Tyler L; Hicks, Kenny L; Draheim, Christopher; Redick, Thomas S; Engle, Randall W
2017-11-01
There is a debate about the ability to improve cognitive abilities such as fluid intelligence through training on tasks of working memory capacity. The question addressed in the research presented here is who benefits the most from training: people with low cognitive ability or people with high cognitive ability? Subjects with high and low working memory capacity completed a 23-session study that included 3 assessment sessions, and 20 sessions of training on 1 of 3 training regiments: complex span training, running span training, or an active-control task. Consistent with other research, the authors found that training on 1 executive function did not transfer to ability on a different cognitive ability. High working memory subjects showed the largest gains on the training tasks themselves relative to the low working memory subjects-a finding that suggests high spans benefit more than low spans from training with executive function tasks. (PsycINFO Database Record (c) 2017 APA, all rights reserved).
Asthma, hypersensitivity pneumonitis and other respiratory diseases caused by metalworking fluids.
Rosenman, Kenneth D
2009-04-01
To highlight advances in understanding the respiratory disease associated with metal machining, a common work process involving approximately 1.2 million workers in the USA. Recent studies emphasize that work-related asthma and hypersensitivity pneumonitis continue to be caused by exposure to metalworking fluid. Identification of an individual patient indicates the need for follow-up investigations at the work site to prevent additional disease and/or identify additional effected individuals. Identification of the causal agent for hypersensitivity pneumonitis has centered on microbial contamination of metalworking fluids with a number of studies focusing on Mycobacterium immunogenum. Both asthma and hypersensitivity pneumonitis occur among workers exposed to metalworking fluid. The incidence of these diseases among such workers is unknown. Outbreaks of these conditions continue to be identified among metal machinists. Whether these are true outbreaks associated with some breakdown in workplace controls or, rather the recognition of ongoing endemic disease that is typically misdiagnosed as pneumonia or common adult onset asthma, needs further evaluation. Further work to elucidate the specific causal agent(s) is necessary to affect effective workplace controls. Treating an identified individual case as an index case with a follow-up workplace investigation will only be possible if practicing physicians interact with public health authorities to report newly diagnosed cases.
Paper-based surfaced enhanced Raman spectroscopy for drug level testing with tear fluid
NASA Astrophysics Data System (ADS)
Yamada, Kenji; Yokoyama, Moe; Jeong, Hieyong; Kido, Michiko; Ohno, Yuko
2015-07-01
The purpose of this study was to show the effectiveness of therapeutic drug level testing by Paper-based Surfaced Enhanced Raman Spectroscopy (PSERS) for artificial lacrimal fluid. We have been used substrates which consist of a common filter paper and gold nano-rods. The targets were Phenobarbital (PB) which dissolved in artificial lacrimal fluid. We measured them using PSERS which the wavelength was 785nm, the power was 30mW. It was found that there were the strong peaks of PB at 997cm-1 and 1026cm-1 which corresponded with solid PB spectral peak for 1mM artificial lacrimal fluid. The results demonstrated the usefulness of this method. It is concluded that our method for therapeutic drug level testing is very efficient.
Nandi, S; Mondal, S; Pal, D T; Gupta, P S P
2016-04-01
This study was undertaken to elucidate the effect of ammonia-generating diet on serum and follicular fluid ammonia and urea levels, serum oestrogen and progesterone concentrations and granulosa cell growth and secretion parameters in ewes (Ovis aries). Ewes were fed with 14% CP diet (control) or ammonia-generating diet or ammonia-generating diet plus soluble sugar. The serum and follicular fluid ammonia and urea level, serum oestrogen and progesterone levels and granulosa cell (obtained from ovaries of slaughtered ewes) growth parameters and secretory activities were estimated. Ammonia-generating diet (high-protein diet) increased the serum ammonia and urea concentration. Supplementation of soluble sugar significantly reduced the ammonia concentration in serum with comparable levels as in control group; however, the urea level in the same group was higher than that observed in control group. Supplementation of soluble sugar significantly reduced the follicular fluid ammonia concentration; however, the level was significantly higher compared to control group. Supplementation of soluble sugar brought down the follicular fluid urea level comparable to that observed in control group. Oestrogen and progesterone levels remained unchanged in ewes fed with different types of diet. Oestrogen and progesterone secretion were significantly lowered from granulosa cells recovered from ewes fed with high ammonia-generating diet. Low metabolic activity and high incidence of apoptosis were observed in granulosa cells obtained from ovaries of ewes fed with ammonia-generating diet. Journal of Animal Physiology and Animal Nutrition © 2015 Blackwell Verlag GmbH.
Fornaro, Felice; Cobellis, Luigi; Mele, Daniela; Tassou, Argyrò; Badolati, Barbara; Sorrentino, Simona; De Lucia, Domenico; Colacurci, Nicola
2007-01-01
To compare the effects of GnRH-agonist/recombinant rFSH versus GnRH-antagonist/recombinant FSH stimulation on follicular fluid levels of soluble intercellular adhesion molecule (sICAM)-1 and vascular cell adhesion molecule-1 (sVCAM-1) during in vitro fertilization (IVF). Prospective, randomized study. University hospital. Seventy-three women underwent IVF. GnRH-agonist/rFSH or GnRH-antagonist/rFSH administration and collection of follicular fluid from 3 small (11-14 mm in diameter) and 3 large (18-21 mm in diameter) follicles on the day of oocyte retrieval. Follicular fluid levels of sICAM-1 and sVCAM-1 and intrafollicular estradiol and progesterone were also measured. Women who underwent GnRH-agonist/rFSH showed higher concentrations of sICAM-1 in both small and large follicles were compared with patients who received GnRH-antagonist/rFSH treatment; follicular fluid levels of sVCAM-1 were similar between the 2 stimulation protocols. Content of sICAM-1 in small and large follicles positively correlated with the number of follicles of > or =15 mm and the number of oocytes that were retrieved in both study groups. Concentrations of follicular fluid sVCAM-1 and progesterone were higher in large than in small follicles and were correlated positively to each other in both follicular classes. In IVF, GnRH-agonist/rFSH is associated with higher follicular fluid levels of sICAM-1 compared with GnRH-antagonist/rFSH regimen. Intrafollicular sICAM-1 content may predict ovarian response, and sVCAM-1 appears as an indicator of the degree of follicular luteinization.
Ideal heat transfer conditions for tubular solar receivers with different design constraints
NASA Astrophysics Data System (ADS)
Kim, Jin-Soo; Potter, Daniel; Gardner, Wilson; Too, Yen Chean Soo; Padilla, Ricardo Vasquez
2017-06-01
The optimum heat transfer condition for a tubular type solar receiver was investigated for various receiver pipe size, heat transfer fluid, and design requirement and constraint(s). Heat transfer of a single plain receiver pipe exposed to concentrated solar energy was modelled along the flow path of the heat transfer fluid. Three different working fluids, molten salt, sodium, and supercritical carbon dioxide (sCO2) were considered in the case studies with different design conditions. The optimized ideal heat transfer condition was identified through fast iterative heat transfer calculations solving for all relevant radiation, conduction and convection heat transfers throughout the entire discretized tubular receiver. The ideal condition giving the best performance was obtained by finding the highest acceptable solar energy flux optimally distributed to meet different constraint(s), such as maximum allowable material temperature of receiver, maximum allowable film temperature of heat transfer fluid, and maximum allowable stress of receiver pipe material. The level of fluid side turbulence (represented by pressure drop in this study) was also optimized to give the highest net power production. As the outcome of the study gives information on the most ideal heat transfer condition, it can be used as a useful guideline for optimal design of a real receiver and solar field in a combined manner. The ideal heat transfer condition is especially important for high temperature tubular receivers (e.g. for supplying heat to high efficiency Brayton cycle turbines) where the system design and performance is tightly constrained by the receiver pipe material strength.
Fluid Distribution for In-space Cryogenic Propulsion
NASA Technical Reports Server (NTRS)
Lear, William
2005-01-01
The ultimate goal of this task is to enable the use of a single supply of cryogenic propellants for three distinct spacecraft propulsion missions: main propulsion, orbital maneuvering, and attitude control. A fluid distribution system is sought which allows large propellant flows during the first two missions while still allowing control of small propellant flows during attitude control. Existing research has identified the probable benefits of a combined thermal management/power/fluid distribution system based on the Solar Integrated Thermal Management and Power (SITMAP) cycle. Both a numerical model and an experimental model are constructed in order to predict the performance of such an integrated thermal management/propulsion system. This research task provides a numerical model and an experimental apparatus which will simulate an integrated thermal/power/fluid management system based on the SITMAP cycle, and assess its feasibility for various space missions. Various modifications are done to the cycle, such as the addition of a regeneration process that allows heat to be transferred into the working fluid prior to the solar collector, thereby reducing the collector size and weight. Fabri choking analysis was also accounted for. Finally the cycle is to be optimized for various space missions based on a mass based figure of merit, namely the System Mass Ratio (SMR). -. 1 he theoretical and experimental results from these models are be used to develop a design code (JETSIT code) which is able to provide design parameters for such a system, over a range of cooling loads, power generation, and attitude control thrust levels. The performance gains and mass savings will be compared to those of existing spacecraft systems.