Sample records for x-ray absorptiometry dxa-derived

  1. Bone geometry, structure and mineral distribution using Dual energy X ray Absorptiometry (DXA)

    NASA Technical Reports Server (NTRS)

    Whalen, Robert; Cleek, Tammy

    1993-01-01

    Dual energy x-ray absorptiometry (DXA) is currently the most widely used method of analyzing regional and whole body changes in bone mineral content (BMC) and areal (g/sq cm) bone mineral density (BMD). However, BMC and BMD do not provide direct measures of long bone geometry, structure, or strength nor do regional measurements detect localized changes in other regions of the same bone. The capabilities of DXA can be enhanced significantly by special processing of pixel BMC data which yields cross-sectional geometric and structural information. We have extended this method of analysis in order to develop non-uniform structural beam models of long bones.

  2. Bone age assessment by dual-energy X-ray absorptiometry in children: an alternative for X-ray?

    PubMed

    Heppe, D H M; Taal, H R; Ernst, G D S; Van Den Akker, E L T; Lequin, M M H; Hokken-Koelega, A C S; Geelhoed, J J M; Jaddoe, V W V

    2012-02-01

    The aim of the study was to validate dual-energy X-ray absorptiometry (DXA) as a method to assess bone age in children. Paired dual-energy X-ray absorptiometry (DXA) scans and X-rays of the left hand were performed in 95 children who attended the paediatric endocrinology outpatient clinic of University Hospital Rotterdam, the Netherlands. We compared bone age assessments by DXA scan with those performed by X-ray. Bone age assessment was performed by two blinded observers according to the reference method of Greulich and Pyle. Intra-observer and interobserver reproducibility were investigated using the intraclass correlation coefficient (ICC), and agreement was tested using Bland and Altman plots. The intra-observer ICCs for both observers were 0.997 and 0.991 for X-ray and 0.993 and 0.987 for DXA assessments. The interobserver ICC was 0.993 and 0.991 for X-ray and DXA assessments, respectively. The mean difference between bone age assessed by X-ray and DXA was 0.11 years. The limits of agreement ranged from -0.82 to 1.05 years, which means that 95% of all differences between the methods were covered by this range. Results of bone age assessment by DXA scan are similar to those obtained by X-ray. The DXA method seems to be an alternative for assessing bone age in a paediatric hospital-based population.

  3. Total and regional body volumes derived from dual-energy X-ray absorptiometry output.

    PubMed

    Wilson, Joseph P; Fan, Bo; Shepherd, John A

    2013-01-01

    Total body volume is an important health metric used to measure body density, shape, and multicompartmental body composition but is currently only available through underwater weighing or air displacement plethysmography (ADP). The objective of this investigation was to derive an accurate body volume from dual-energy X-ray absorptiometry (DXA)-reported measures for advanced body composition models. Volunteers received a whole body DXA scan and an ADP measure at baseline (N = 25) and 6 mo (N = 22). Baseline measures were used to calibrate body volume from the reported DXA masses of fat, lean, and bone mineral content. A second population (N = 385) from the National Health and Nutrition Examination Survey was used to estimate the test-retest precision of regional (arms, legs, head, and trunk) and total body volumes. Overall, we found that DXA-volume was highly correlated to ADP-volume (R² = 0.99). The 6-mo change in total DXA-volume was highly correlated to change in ADP-volume (R² = 0.98). The root mean square percent coefficient of variation precision of DXA-volume measures ranged from 1.1% (total) to 3.2% (head). We conclude that the DXA-volume method can measure body volume accurately and precisely, can be used in body composition models, could be an independent health indicator, and is useful as a prospective or retrospective biomarker of body composition. Copyright © 2013 The International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.

  4. Cortical thickness estimation of the proximal femur from multi-view dual-energy X-ray absorptiometry (DXA)

    NASA Astrophysics Data System (ADS)

    Tsaousis, N.; Gee, A. H.; Treece, G. M.; Poole, K. E. S.

    2013-02-01

    Hip fracture is the leading cause of acute orthopaedic hospital admission amongst the elderly, with around a third of patients not surviving one year post-fracture. Although various preventative therapies are available, patient selection is difficult. The current state-of-the-art risk assessment tool (FRAX) ignores focal structural defects, such as cortical bone thinning, a critical component in characterizing hip fragility. Cortical thickness can be measured using CT, but this is expensive and involves a significant radiation dose. Instead, Dual-Energy X-ray Absorptiometry (DXA) is currently the preferred imaging modality for assessing hip fracture risk and is used routinely in clinical practice. Our ambition is to develop a tool to measure cortical thickness using multi-view DXA instead of CT. In this initial study, we work with digitally reconstructed radiographs (DRRs) derived from CT data as a surrogate for DXA scans: this enables us to compare directly the thickness estimates with the gold standard CT results. Our approach involves a model-based femoral shape reconstruction followed by a data-driven algorithm to extract numerous cortical thickness point estimates. In a series of experiments on the shaft and trochanteric regions of 48 proximal femurs, we validated our algorithm and established its performance limits using 20 views in the range 0°-171°: estimation errors were 0:19 +/- 0:53mm (mean +/- one standard deviation). In a more clinically viable protocol using four views in the range 0°-51°, where no other bony structures obstruct the projection of the femur, measurement errors were -0:07 +/- 0:79 mm.

  5. Basic investigation of dual-energy x-ray absorptiometry for bone densitometry using computed radiography

    NASA Astrophysics Data System (ADS)

    Shimura, Kazuo; Nakajima, Nobuyoshi; Tanaka, Hiroshi; Ishida, Masamitsu; Kato, Hisatoyo

    1993-09-01

    Dual-energy X-ray absorptiometry (DXA) is one of the bone densitometry techniques to diagnose osteoporosis, and has been gradually getting popular due to its high degree of precision. However, DXA involves a time-consuming examination because of its pencil-beam scan, and the equipment is expensive. In this study, we examined a new bone densitometry technique (CR-DXA) utilizing an X-ray imaging system and Computed Radiography (CR) used for medical X-ray image diagnosis. High level of measurement precision and accuracy could be achieved by X-ray rube voltage/filter optimization and various nonuniformity corrections based on simulation and experiment. The phantom study using a bone mineral block showed precision of 0.83% c.v. (coefficient of variation), and accuracy of 0.01 g/cm2, suggesting that a practically equivalent degree of measurement precision and accuracy to that of the DXA approach is achieved. CR-DXA is considered to provide bone mineral densitometry to facilitate simple, quick and precise bone mineral density measurement.

  6. Comparison of Anthropometry to Dual Energy X-Ray Absorptiometry: A New Prediction Equation for Women

    ERIC Educational Resources Information Center

    Ball, Stephen; Swan, Pamela D.; DeSimone, Rosemarie

    2004-01-01

    The purpose of this study was to assess the accuracy of three recommended anthropometric equations for women and then develop an updated prediction equation using dual energy x-ray absorptiometry (DXA). The percentage of body fat (%BF) by anthropometry was significantly correlated (r = .896-. 929; p [is less than] .01) with DXA, but each equation…

  7. Air displacement plethysmography versus dual-energy x-ray absorptiometry in underweight, normal-weight, and overweight/obese individuals.

    PubMed

    Lowry, David W; Tomiyama, A Janet

    2015-01-01

    Accurately estimating fat percentage is important for assessing health and determining treatment course. Methods of estimating body composition such as hydrostatic weighing or dual-energy x-ray absorptiometry (DXA), however, can be expensive, require extensive operator training, and, in the case of hydrostatic weighing, be highly burdensome for patients. Our objective was to evaluate air displacement plethysmography via the Bod Pod, a less burdensome method of estimating body fat percentage. In particular, we filled a gap in the literature by testing the Bod Pod at the lower extreme of the Body Mass Index (BMI) distribution. Three BMI groups were recruited and underwent both air displacement plethysmography and dual-energy x-ray absorptiometry. We recruited 30 healthy adults at the lower BMI distribution from the Calorie Restriction (CR) Society and followers of the CR Way. We also recruited 15 normal weight and 19 overweight/obese healthy adults from the general population. Both Siri and Brozek equations derived body fat percentage from the Bod Pod, and Bland-Altman analyses assessed agreement between the Bod Pod and DXA. Compared to DXA, the Bod Pod overestimated body fat percentage in thinner participants and underestimated body fat percentage in heavier participants, and the magnitude of difference was larger for underweight BMI participants, reaching 13% in some. The Bod Pod and DXA had smaller discrepancies in normal weight and overweight/obese participants. While less burdensome, clinicians should be aware that Bod Pod estimates may deviate from DXA estimates particularly at the lower end of the BMI distribution.

  8. Air Displacement Plethysmography versus Dual-Energy X-Ray Absorptiometry in Underweight, Normal-Weight, and Overweight/Obese Individuals

    PubMed Central

    Lowry, David W.; Tomiyama, A. Janet

    2015-01-01

    Background Accurately estimating fat percentage is important for assessing health and determining treatment course. Methods of estimating body composition such as hydrostatic weighing or dual-energy x-ray absorptiometry (DXA), however, can be expensive, require extensive operator training, and, in the case of hydrostatic weighing, be highly burdensome for patients. Our objective was to evaluate air displacement plethysmography via the Bod Pod, a less burdensome method of estimating body fat percentage. In particular, we filled a gap in the literature by testing the Bod Pod at the lower extreme of the Body Mass Index (BMI) distribution. Findings Three BMI groups were recruited and underwent both air displacement plethysmography and dual-energy x-ray absorptiometry. We recruited 30 healthy adults at the lower BMI distribution from the Calorie Restriction (CR) Society and followers of the CR Way. We also recruited 15 normal weight and 19 overweight/obese healthy adults from the general population. Both Siri and Brozek equations derived body fat percentage from the Bod Pod, and Bland-Altman analyses assessed agreement between the Bod Pod and DXA. Compared to DXA, the Bod Pod overestimated body fat percentage in thinner participants and underestimated body fat percentage in heavier participants, and the magnitude of difference was larger for underweight BMI participants, reaching 13% in some. The Bod Pod and DXA had smaller discrepancies in normal weight and overweight/obese participants. Conclusions While less burdensome, clinicians should be aware that Bod Pod estimates may deviate from DXA estimates particularly at the lower end of the BMI distribution. PMID:25607661

  9. Dual-energy X-ray absorptiometry is a valid tool for assessing skeletal muscle mass in older women.

    PubMed

    Chen, Zhao; Wang, ZiMian; Lohman, Timothy; Heymsfield, Steven B; Outwater, Eric; Nicholas, Jennifer S; Bassford, Tamsen; LaCroix, Andrea; Sherrill, Duane; Punyanitya, Mark; Wu, Guanglin; Going, Scott

    2007-12-01

    Assessing skeletal muscle mass (SMM) is critical in studying and detecting sarcopenia. Direct measurements by MRI or computerized tomography are expensive or high in radiation exposure. Dual-energy X-ray absorptiometry (DXA) is promising for body composition assessments, but the validity of DXA for predicting SMM in the elderly is still under investigation. The objective of this study was to assess the relationship between DXA-derived measurements of lean soft tissue mass (LSTM) and SMM in older women. Study participants were postmenopausal women (n = 101) recruited in southern Arizona. Total and regional body composition was measured using MRI and DXA (QDR4500w). The participants' mean age was 70.7 +/- 6.4 y and their mean BMI was 27.4 +/- 5.1 kg/m2. DXA-derived LSTM was highly correlated with MRI-derived SMM for the whole body (r = 0.94; P < 0.001) and leg region (r = 0.91; P < 0.001). In multivariate models, adjusting for age and DXA-derived percent fat slightly increased the amount of variance in SMM that can be explained by the DXA-derived LSTM assessments for the leg region but not for the total body. In conclusion, although the relationships between DXA measures and MRI-derived SMM vary by region of interest, the overall prediction of SMM by DXA is excellent. We conclude that DXA is a reliable method for cross-sectional assessments of SMM in older women.

  10. Agreement Between Bioelectrical Impedance and Dual-Energy X-Ray Absorptiometry to Track Changes in Fat-Free Mass After Resistance Training in Older Women.

    PubMed

    Nascimento, Matheus A; Silva, Danilo R P; Ribeiro, Alex S; Pina, Fábio L C; Gerage, Aline M; Gobbo, Luís A; Mayhew, Jerry L; Cyrino, Edilson S

    2018-05-23

    Nascimento, MA, Silva, DRP, Ribeiro, AS, Pina, FLC, Gerage, AM, Gobbo, LA, Mayhew, JL, and Cyrino, ES. Agreement between bioelectrical impedance and dual-energy x-ray absorptiometry to track changes in fat-free mass after resistance training in older women. J Strength Cond Res XX(X): 000-000, 2018-The aim of our study was to compare the agreement between bioelectrical impedance (BIA) and dual-energy X-ray absorptiometry (DXA) to track changes on fat-free mass (FFM) after a resistance training (RT) program in older women. Forty-three older women (65.2 ± 4.6 years, 59.5 ± 9.2 kg, 156.4 ± 6.0 cm, 24.3 ± 3.3 kg·m) participated in a RT intervention (12 weeks, 8 exercises, 2 sets, 10-15 repetitions, 3 nonconsecutive days per week). Fat-free mass changes were determined by a single-frequency BIA device (EQ1), 6 BIA prediction equations for older women (EQ2, EQ3, EQ4, EQ5, EQ6, and EQ7), and DXA. At pretraining, 3 equations overpredicted, and 3 underpredicted DXA FFM (F = 244.63, p < 0.001), although all equations had high correlations with DXA (r = 0.78-0.83). After training, 4 equations overpredicted and one underpredicted DXA FFM (F = 176.25, p < 0.001). Dual-energy X-ray absorptiometry detected significant gains in FFM (0.65 ± 0.82 kg; p < 0.05), as did EQ3 (0.55 ± 1.69 kg; p < 0.05), and EQ4 (0.61 ± 1.88 kg; p < 0.05), whereas the remaining equations did not indicate significant changes in FFM. Low correlations between FFM and equation change values suggest that single-frequency BIA-derived equations may not provide sufficient accuracy to track changes in FFM after 12 weeks of RT in older women.

  11. Reliability of analysis of the bone mineral density of the second and fifth metatarsals using dual-energy x-ray absorptiometry (DXA).

    PubMed

    Pritchard, N Stewart; Smoliga, James M; Nguyen, Anh-Dung; Branscomb, Micah C; Sinacore, David R; Taylor, Jeffrey B; Ford, Kevin R

    2017-01-01

    Metatarsal fractures, especially of the fifth metatarsal, are common injuries of the foot in a young athletic population, but the risk factors for this injury are not well understood. Dual-energy x-ray absorptiometry (DXA) provides reliable measures of regional bone mineral density to predict fracture risk in the hip and lumbar spine. Recently, sub-regional metatarsal reliability was established in fresh cadaveric specimens and associated with ultimate fracture force. The purpose of this study was to assess the reliability of DXA bone mineral density measurements of sub-regions of the second and fifth metatarsals in a young, active population. Thirty two recreationally active individuals participated in the study, and the bone density of the second (2MT) and fifth (5MT) metatarsals of each subject was measured using a Hologic QDR x-ray bone densitometer. Scans were analyzed separately by two raters, and regional bone mineral density, bone mineral content, and area measurements were calculated for the proximal, shaft, and distal regions of the bone. Intra-rater, inter-rater, and scan-rescan reliability were then determined for each region. Proximal and shaft bone mineral density measurements of the second and fifth metatarsal were reliable. ICC's were variable across regions and metatarsals, with the distal region being the poorest. Bone mineral density measurements of the metatarsals may be a better indicator of fracture risk of the metatarsals than whole body measurements. A reliable method for measuring the regional bone mineral densities of the metatarsals was found. However, inter-rater reliability and scan-rescan reliability for the distal regions were poor. Future research should examine the relationship between DXA bone mineral density measurements and fracture risk at the metatarsals.

  12. Preoperative and postoperative agreement in fat free mass (FFM) between bioelectrical impedance spectroscopy (BIS) and dual-energy X-ray absorptiometry (DXA) in patients undergoing cardiac surgery.

    PubMed

    van Venrooij, Lenny M W; Verberne, Hein J; de Vos, Rien; Borgmeijer-Hoelen, Mieke M M J; van Leeuwen, Paul A M; de Mol, Bas A J M

    2010-12-01

    To measure undernutrition in terms of fat free mass (FFM), there are several options. The aim of this study was to assess agreement in FFM between the portable, bedside bioelectrical impedance spectrometry (BIS) and relatively expensive, non-portable dual-energy X-ray absorptiometry (DXA) in patients undergoing cardiac surgery. In a prospective study, body composition measurements by BIS and DXA were performed two weeks prior and two months after cardiac surgery. Preoperative and postoperative agreement in FFM between BIS and DXA were analyzed with Bland and Altman plots. Twenty-six patients were analyzed. BIS overestimated preoperative and postoperative FFM by 2 kg compared to DXA (2.3 kg (95%CI: -3.5-8.1 kg) and 2.1 kg (95%CI: -4.5-8.7 kg), respectively). BIS underestimated FFM change by -0.5% (95%CI: -8.4-7.5%). There is a large inter-individual variation between BIS and DXA. This hinders the interchange-ability of BIS and DXA in routine clinical practice and may lead to misclassifications and thereby inappropriate nutritional treatment and possible postoperative complications. To evaluate nutritional therapy in patients undergoing cardiac surgery, we advocate the use of DXA assessed FFM in parallel to BIS assessed extracellular and intracellular water and FFM. Copyright © 2010 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.

  13. Use of dual-energy X-ray absorptiometry (DXA) for diagnosis and fracture risk assessment; WHO-criteria, T- and Z-score, and reference databases.

    PubMed

    Dimai, Hans P

    2017-11-01

    Dual-energy X-ray absorptiometry (DXA) is a two-dimensional imaging technology developed to assess bone mineral density (BMD) of the entire human skeleton and also specifically of skeletal sites known to be most vulnerable to fracture. In order to simplify interpretation of BMD measurement results and allow comparability among different DXA-devices, the T-score concept was introduced. This concept involves an individual's BMD which is then compared with the mean value of a young healthy reference population, with the difference expressed as a standard deviation (SD). Since the early nineties of the past century, the diagnostic categories "normal, osteopenia, and osteoporosis", as recommended by a WHO working Group, are based on this concept. Thus, DXA is still the globally accepted "gold-standard" method for the noninvasive diagnosis of osteoporosis. Another score obtained from DXA measurement, termed Z-score, describes the number of SDs by which the BMD in an individual differs from the mean value expected for age and sex. Although not intended for diagnosis of osteoporosis in adults, it nevertheless provides information about an individual's fracture risk compared to peers. DXA measurement can either be used as a "stand-alone" means in the assessment of an individual's fracture risk, or incorporated into one of the available fracture risk assessment tools such as FRAX® or Garvan, thus improving the predictive power of such tools. The issue which reference databases should be used by DXA-device manufacturers for T-score reference standards has been recently addressed by an expert group, who recommended use National Health and Nutrition Examination Survey III (NHANES III) databases for the hip reference standard but own databases for the lumbar spine. Furthermore, in men it is recommended use female reference databases for calculation of the T-score and use male reference databases for calculation of Z-score. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Comparison of DXA Scans and Conventional X-rays for Spine Morphometry and Bone Age Determination in Children.

    PubMed

    Hoyer-Kuhn, Heike; Knoop, Kai; Semler, Oliver; Kuhr, Kathrin; Hellmich, Martin; Schoenau, Eckhard; Koerber, Friederike

    2016-01-01

    Conventional lateral spine and hand radiographs are the standard tools to evaluate vertebral morphometry and bone age in children. Beside bone mineral density analyses, dual-energy X-ray absorptiometry (DXA) measurements with lower radiation exposure provide high-resolution scans which are not approved for diagnostic purposes. Data about the comparability of conventional radiographs and DXA in children are missing yet. The purpose of the trial was to evaluate whether conventional hand and spine radiographs can be replaced by DXA scans to diminish radiation exposure. Thirty-eight children with osteogenesis imperfecta or secondary osteoporosis or short stature (male, n=20; age, 5.0-17.0 yr) were included and assessed once by additional DXA (GE iDXA) of the spine or the left hand. Intraclass correlation coefficients (ICCs) were used to express agreement between X-ray and iDXA assessment. Evaluation of the spine morphometry showed reasonable agreement between iDXA and radiography (ICC for fish-shape, 0.75; for wedge-shape, 0.65; and for compression fractures, 0.70). Bone age determination showed excellent agreement between iDXA and radiography (ICC, 0.97). IDXA-scans of the spine in a pediatric population should be used not only to assess bone mineral density but also to evaluate anatomic structures and vertebral morphometry. Therefore, iDXA can replace some radiographs in children with skeletal diseases. Copyright © 2016 The International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.

  15. Measuring body composition in dogs using multifrequency bioelectrical impedance analysis and dual energy X-ray absorptiometry.

    PubMed

    Rae, L S; Vankan, D M; Rand, J S; Flickinger, E A; Ward, L C

    2016-06-01

    Thirty-five healthy, neutered, mixed breed dogs were used to determine the ability of multifrequency bioelectrical impedance analysis (MFBIA) to predict accurately fat-free mass (FFM) in dogs using dual energy X-ray absorptiometry (DXA)-measured FFM as reference. A second aim was to compare MFBIA predictions with morphometric predictions. MFBIA-based predictors provided an accurate measure of FFM, within 1.5% when compared to DXA-derived FFM, in normal weight dogs. FFM estimates were most highly correlated with DXA-measured FFM when the prediction equation included resistance quotient, bodyweight, and body condition score. At the population level, the inclusion of impedance as a predictor variable did not add substantially to the predictive power achieved with morphometric variables alone; in individual dogs, impedance predictors were more valuable than morphometric predictors. These results indicate that, following further validation, MFBIA could provide a useful tool in clinical practice to objectively measure FFM in canine patients and help improve compliance with prevention and treatment programs for obesity in dogs. Copyright © 2016. Published by Elsevier Ltd.

  16. Assessment of adiposity in psoriatic patients by dual energy X-ray absorptiometry compared to conventional methods*

    PubMed Central

    Diniz, Michelle dos Santos; Bavoso, Nádia Couto; Kakehasi, Adriana Maria; Lauria, Márcio Weissheimer; Soares, Maria Marta Sarquis; Machado-Pinto, Jackson

    2016-01-01

    BACKGROUND Obesity is considered a chronic low-grade inflammatory disease that shares mediators of inflammation with psoriasis, such as TNF-α and IL-6. The relationship between these two conditions involves factors such as predisposition and response to therapy, in addition to an association with cardiovascular disease. OBJECTIVES The aim of the present study was to investigate the prevalence of adiposity as determined by body mass index (BMI), waist circumference (WC), and dual energy X-ray absorptiometry (DXA) evaluation in patients with psoriasis. METHODS BMI, WC and body composition by DXA were measured in 42 psoriatic patients without joint complaints and in 41 control patients using standard procedures. In the comparison between cases and controls, we used Pearson’s Χ2 test or Fisher’s exact test, and the nonparametric Mann-Whitney test. The difference between the diverse classification methods for obesity was evaluated using McNemar’s test. To test the level of agreement between those variables, we used the weighted kappa coefficient. RESULTS There was no difference in the prevalence of obesity among cases and controls. Both BMI and WC had low agreement with measures of body fat evaluated by DXA. With the use of DXA scanning, prevalence of overweight and obesity in patients with psoriasis was 83.3%, which constitutes a strong evidence of the need for intervention on this metabolic parameter. CONCLUSION Dual energy X-ray absorptiometry was more capable of identifying obesity compared with BMI and WC both in psoriatic and control patients. PMID:27192512

  17. Reference standards for body fat measures using GE dual energy x-ray absorptiometry in Caucasian adults.

    PubMed

    Imboden, Mary T; Welch, Whitney A; Swartz, Ann M; Montoye, Alexander H K; Finch, Holmes W; Harber, Matthew P; Kaminsky, Leonard A

    2017-01-01

    Dual energy x-ray absorptiometry (DXA) is an established technique for the measurement of body composition. Reference values for these variables, particularly those related to fat mass, are necessary for interpretation and accurate classification of those at risk for obesity-related health complications and in need of lifestyle modifications (diet, physical activity, etc.). Currently, there are no reference values available for GE-Healthcare DXA systems and it is known that whole-body and regional fat mass measures differ by DXA manufacturer. To develop reference values by age and sex for DXA-derived fat mass measurements with GE-Healthcare systems. A de-identified sample of 3,327 participants (2,076 women, 1,251 men) was obtained from Ball State University's Clinical Exercise Physiology Laboratory and University of Wisconsin-Milwaukee's Physical Activity & Health Research Laboratory. All scans were completed using a GE Lunar Prodigy or iDXA and data reported included percent body fat (%BF), fat mass index (FMI), and ratios of android-to-gynoid (A/G), trunk/limb, and trunk/leg fat measurements. Percentiles were calculated and a factorial ANOVA was used to determine differences in the mean values for each variable between age and sex. Normative reference values for fat mass variables from DXA measurements obtained from GE-Healthcare DXA systems are presented as percentiles for both women and men in 10-year age groups. Women had higher (p<0.01) mean %BF and FMI than men, whereas men had higher (p<0.01) mean ratios of A/G, trunk/limb, and trunk/leg fat measurements than women. These reference values provide clinicians and researchers with a resource for interpretation of DXA-derived fat mass measurements specific to use with GE-Healthcare DXA systems.

  18. Fundamental Movement Skill Proficiency and Body Composition Measured by Dual Energy X-Ray Absorptiometry in Eight-Year-Old Children

    ERIC Educational Resources Information Center

    Slotte, Sari; Sääkslahti, Arja; Metsämuuronen, Jari; Rintala, Pauli

    2015-01-01

    Objective: The main aim was to examine the association between fundamental movement skills (FMS) and objectively measured body composition using dual energy X-ray absorptiometry (DXA). Methods: A study of 304 eight-year-old children in Finland. FMS were assessed with the "Test of gross motor development," 2nd ed. Total body fat…

  19. Impact of hemodialysis on dual X-ray absorptiometry, bioelectrical impedance measurements, and anthropometry.

    PubMed

    Abrahamsen, B; Hansen, T B; Høgsberg, I M; Pedersen, F B; Beck-Nielsen, H

    1996-01-01

    Dual X-ray absorptiometry (DXA) performs noninvasive assessment of bone and soft tissue with high precision. However, soft tissue algorithms assume that 73.2% of the lean body mass is water, a potential source of error in fluid retention. We evaluated DXA (model QDR-2000; Hologic Inc, Waltham, MA), bioelectrical impedance analysis (BIA), and simple anthropometry in 19 patients (9 women and 10 men, mean age 46 y) before and after hemodialysis, removing 0.9-4.3 L (x: 2.8L) of ultrafiltrate. The reduction in fat-free mass (FFM) measured by DXA was highly correlated with the ultrafiltrate, as determined by the reduction in gravimetric weight (r = 0.975, P < 0.0001; SEE: 233 g), whereas BIA was considerably less accurate in assessing FFM reductions (r = 0.66, P < 0.01; SEE: 757 g). Lumbar bone mineral density (BMD) was unaffected by dialysis, as were whole-body fat and BMD. Whole-body bone mineral content, however, was estimated to be 0.6% lower after dialysis. None of the simple anthropometric measurements correlated significantly with the reduction in FFM. In an unmodified clinical setting, DXA appears to be superior to other simple noninvasive methods for determining body composition, particularly when the emphasis is on repeated measurements.

  20. Dual-energy X-ray absorptiometry derived structural geometry for stress fracture prediction in male U.S. Marine Corps recruits.

    PubMed

    Beck, T J; Ruff, C B; Mourtada, F A; Shaffer, R A; Maxwell-Williams, K; Kao, G L; Sartoris, D J; Brodine, S

    1996-05-01

    A total of 626 U.S. male Marine Corps recruits underwent anthropometric measurements and dual-energy X-ray absorptiometry (DXA) scans of the femoral midshaft and the distal third of the tibia prior to a 12 week physical training program. Conventionally obtained frontal plane DXA scan data were used to measure the bone mineral density (BMD) as well as to derive the cross-sectional area, moment of inertia, section modulus, and bone width in the femur, tibia, and fibula. During training, 23 recruits (3.7%) presented with a total of 27 radiologically confirmed stress fractures in various locations in the lower extremity. After excluding 16 cases of shin splints, periostitis, and other stress reactions that did not meet fracture definition criteria, we compared anthropometric and bone structural geometry measurements between fracture cases and the remaining 587 normals. There was no significant difference in age (p = 0.8), femur length (p = 0.2), pelvic width (p = 0.08), and knee width at the femoral condyles (p = 0.06), but fracture cases were shorter (p = 0.01), lighter (p = 0.0006), and smaller in most anthropometric girth dimensions (p < 0.04). Fracture case bone cross-sectional areas (p < 0.001), moments of inertia (p < 0.001), section moduli (p < 0.001), and widths (p < 0.001) as well as BMD (p < 0.03) were significantly smaller in the tibia and femur. After correcting for body weight differences, the tibia cross-sectional area (p = 0.03), section modulus (p = 0.05), and width (p = 0.03) remained significantly smaller in fracture subjects. We conclude that both small body weight and small diaphyseal dimensions relative to body weight are factors predisposing to the development of stress fractures in this population. These results suggest that bone structural geometry measurements derived from DXA data may provide a simple noninvasive methodology for assessing the risk of stress fracture.

  1. Reference standards for lean mass measures using GE dual energy x-ray absorptiometry in Caucasian adults

    PubMed Central

    Imboden, Mary T.; Swartz, Ann M.; Finch, Holmes W.; Harber, Matthew P.; Kaminsky, Leonard A.

    2017-01-01

    Body composition assessments commonly focus predominantly on fat mass, however lean mass (LM) measurements also provide useful information regarding clinical and nutritional status. LM measurements help predict health outcomes and diagnose sarcopenia, which has been associated with frailty. Dual energy x-ray absorptiometry (DXA) is an established technique used in clinical and research settings to assess body composition including total and regional LM. Currently, there are no reference values available that were derived from GE-Healthcare DXA systems directly for US adults for LM, LM index (LMI), percent LM (%LM), and appendicular lean mass index (ALMI) and it is known that whole-body and regional LM measures differ by DXA manufacturer. Objective To develop reference values by age and sex for LM measures using GE-Healthcare DXA systems. Methods A de-identified sample was obtained from Ball State University’s Clinical Exercise Physiology Laboratory and University of Wisconsin-Milwaukee’s Physical Activity & Health Research Laboratory. DXA scans of 2,076 women and 1,251 men were completed using a GE Lunar Prodigy or iDXA. Percentiles (%ile) were calculated for all variables of interest (LM, LMI, %LM, and ALMI) and a factorial ANOVA was used to assess differences for each variable between 10-year age groups and sex, as well as the interaction between age and sex. Results Men had higher mean total LM, %LM, LMI, and ALMI than women (p<0.01), across all age groups. All LM variables decreased significantly over the 5 decades in men, however in women only total LM, %LM, and ALMI decreased from the youngest to oldest age groups (p<0.01). Conclusion These reference values provide for a more accurate interpretation of GE-Healthcare DXA-derived LM measurements offering clinicians and researchers with an initial resource to aid in the early detection and assessment of LM deficits. PMID:28426779

  2. Upper and lower limbs composition: a comparison between anthropometry and dual-energy X-ray absorptiometry in healthy people.

    PubMed

    Diano, Danila; Ponti, Federico; Guerri, Sara; Mercatelli, Daniele; Amadori, Michele; Aparisi Gómez, Maria Pilar; Battista, Giuseppe; Guglielmi, Giuseppe; Bazzocchi, Alberto

    2017-09-18

    The detection of changes in lean mass (LM) distribution can help to prevent disability. This study assessed the degree of association between anthropometric measurements and dual-energy X-ray absorptiometry (DXA) body composition (BC) parameters of the upper and lower limbs in a healthy general population and collected DXA age- and sex-specific values of BC that can be useful to build a reference standard. The primary aim of this study was to investigate the reliability of some widely available anthropometric measurements in the assessment of body composition (BC) at the limbs, especially in terms of muscle mass, in a large sample of healthy subjects of different age bands and sex, using fat mass (FM) and lean mass (LM) parameters derived by dual-energy X-ray absorptiometry (DXA) as the gold standard. The secondary aim was to collect DXA age- and sex-specific values of BC of left and right limbs (upper and lower) in a healthy Italian population to be used as reference standards. Two hundred fifty healthy volunteers were enrolled. Arm circumference (AC) and thigh circumference (ThC) were measured, and total and regional BC parameters were obtained by a whole-body DXA scan (Lunar iDXA, Madison, WI, USA; enCORE™ 2011 software version 13.6). FM/LM showed only fair correlation with AC and ThC in females (r = 0.649 and 0.532, respectively); in males and in the total population, the correlation was low (r = 0.360 or lower, and p non-statistically significant). AC and ThC were not well representative of arms LM in both genders (females r = 0.452, males r = 0.530) independently of age. In general, men of all age groups showed higher values of LM and lean mass index (LMI) in both total and segmental upper and lower limbs. In males, the maximum LM and LMI were achieved in the fifth decade in both upper and lower limbs and then started to decrease with aging. In females, no significant modification with aging was identified in LM and LMI. According to our results

  3. Lower Lean Mass Measured by Dual-Energy X-ray Absorptiometry (DXA) is Not Associated with Increased Risk of Hip Fracture in Women: The Framingham Osteoporosis Study.

    PubMed

    McLean, Robert R; Kiel, Douglas P; Berry, Sarah D; Broe, Kerry E; Zhang, Xiaochun; Cupples, L Adrienne; Hannan, Marian T

    2018-01-05

    Although muscle mass influences strength in older adults, it is unclear whether low lean mass measured by dual-energy X-ray absorptiometry (DXA) is an independent risk factor for hip fracture. Our objective was to determine the association between DXA lean mass and incident hip fracture risk among 1978 women aged 50 years and older participating in the Framingham Study Original and Offspring cohorts. Leg and total body lean mass (kg) were assessed from whole-body DXA scans collected in 1992-2001. Hip fracture follow-up extended from DXA assessment to the occurrence of fracture, death, drop-out, or end of follow-up in 2007. Cox proportional hazards regression was used to calculate hazard ratios (HR) and 95% confidence intervals (CI) estimating the relative risk of hip fracture associated with a 1-kg increase in baseline lean mass. Mean age was 66 years (range 50-93). Over a median of 8 years of follow-up, 99 hip fractures occurred. In models adjusted for age, height, study cohort, and percent total body fat, neither leg (HR 1.11; 95% CI 0.94, 1.31) nor total body (HR 1.06; 95% CI 0.99, 1.13) lean mass were associated with hip fracture. After further adjustment for femoral neck bone mineral density, leg lean mass results were similar (HR 1.10; 95% CI 0.93, 1.30). In contrast, 1 kg greater total body lean mass was associated with 9% higher hip fracture risk (HR 1.09; 95% CI 1.02, 1.18). Our findings suggest that in women, lower lean mass measured by DXA is not associated with increased risk of hip fracture.

  4. Comparison of Circumference Measures and Height-Weight Tables With Dual-Energy X-Ray Absorptiometry Assessment of Body Composition in R.O.T.C. Cadets.

    PubMed

    Mitchell, Katherine M; Pritchett, Robert C; Gee, David L; Pritchett, Kelly L

    2017-09-01

    Mitchell, KM, Pritchett, RC, Gee, DL, and Pritchett, KL. Comparison of circumference measures and height-weight tables with dual-energy X-ray absorptiometry assessment of body composition in R.O.T.C. cadets. J Strength Cond Res 31(9): 2552-2556, 2017-Height-weight tables and circumference measures are used by the U.S. Army to predict body composition because they require little equipment or expertise. However, agreement between the Army's new 2002 circumference equation and an established laboratory technique has not been determined. The purpose of this study was to quantify agreement in body fat percentages between the Army's circumference measures (taping) and dual-energy X-ray absorptiometry (DXA); second to determine categorical agreement between height-weight tables and DXA. Male Reserve Officer Training Corps (R.O.T.C.) cadets (N = 23; 20.6 ± 1.6 years, 179.1 ± 6.6 cm; 81.4 ± 10.3 kg) were taped according to Army protocol to predict body fat. The % body fat prediction was compared with DXA through a Bland-Altman Plot with ±2-4% body fat established as a zone of agreement (ZOA). Thirteen out of 23 cadets fell outside the ZOA. No cadet was over the compliance threshold (20-22% fat) using the tape method, however, with DXA, 7 out of 23 cadets were noncompliant. Height-weight tables provided a moderate level of categorical agreement with DXA. The results depict poor agreement between taping and DXA, as taping generally underestimated % body fat. Compared with taping, height-weight tables were better able to identify excess fat weight.

  5. Dual-energy X-ray absorptiometry: analysis of pediatric fat estimate errors due to tissue hydration effects.

    PubMed

    Testolin, C G; Gore, R; Rivkin, T; Horlick, M; Arbo, J; Wang, Z; Chiumello, G; Heymsfield, S B

    2000-12-01

    Dual-energy X-ray absorptiometry (DXA) percent (%) fat estimates may be inaccurate in young children, who typically have high tissue hydration levels. This study was designed to provide a comprehensive analysis of pediatric tissue hydration effects on DXA %fat estimates. Phase 1 was experimental and included three in vitro studies to establish the physical basis of DXA %fat-estimation models. Phase 2 extended phase 1 models and consisted of theoretical calculations to estimate the %fat errors emanating from previously reported pediatric hydration effects. Phase 1 experiments supported the two-compartment DXA soft tissue model and established that pixel ratio of low to high energy (R values) are a predictable function of tissue elemental content. In phase 2, modeling of reference body composition values from birth to age 120 mo revealed that %fat errors will arise if a "constant" adult lean soft tissue R value is applied to the pediatric population; the maximum %fat error, approximately 0.8%, would be present at birth. High tissue hydration, as observed in infants and young children, leads to errors in DXA %fat estimates. The magnitude of these errors based on theoretical calculations is small and may not be of clinical or research significance.

  6. Liver in the analysis of body composition by dual-energy X-ray absorptiometry

    PubMed Central

    Bazzocchi, A; Diano, D; Albisinni, U; Marchesini, G; Battista, G

    2014-01-01

    Objective: To investigate the predictive value for hepatic steatosis of a new software for the quantification of visceral fat by dual-energy X-ray absorptiometry (DXA) and to design new regions of interest (ROIs). Methods: Adult volunteers were prospectively screened for hepatic steatosis by ultrasonography to obtain a well-balanced population according to the presence/absence of the disease. 90 adult patients without steatosis and 90 with steatosis (mild, 53.3%; moderate, 37.7%; and severe, 10.0%) were recruited. On the same day, all subjects were submitted to blood testing and to anthropometric and whole-body DXA for body composition evaluation. A new software for android visceral fat assessment was employed, and six new “liver-suited” ROIs as well as two modified android ROIs were designed. Their association with steatosis grade was tested by correlation analysis. Results: Fat mass (FM) of the new ROIs showed the highest correlation coefficients with steatosis grade (ρ = 0.610–0.619; p < 0.001), which was also confirmed by multivariate analysis. On the whole population, the new ROIs maintained the highest predictive role for liver steatosis, with areas under the receiver operating characteristic curve up to 0.820 ± 0.032. Inter- and intra-operator agreement for the new ROIs was excellent (k = 0.915–1.000 and k = 0.927–1.000). Conclusion: New ROIs could be designed, standardized and implemented in DXA whole-body scan to provide more specific and predictive values of hepatic lipid content. Advances in knowledge: This is the first study to investigate the predictive value for hepatic steatosis of visceral and regional FM assessed on the hepatic site by DXA in comparison with ultrasonography, anthropometry and surrogate markers derived by previously validated algorithms (fatty liver index). PMID:24919499

  7. Techniques for deriving tissue structure from multiple projection dual-energy x-ray absorptiometry

    NASA Technical Reports Server (NTRS)

    Feldmesser, Howard S. (Inventor); Charles, Jr., Harry K. (Inventor); Beck, Thomas J. (Inventor); Magee, Thomas C. (Inventor)

    2004-01-01

    Techniques for deriving bone properties from images generated by a dual-energy x-ray absorptiometry apparatus include receiving first image data having pixels indicating bone mineral density projected at a first angle of a plurality of projection angles. Second image data and third image data are also received. The second image data indicates bone mineral density projected at a different second angle. The third image data indicates bone mineral density projected at a third angle. The third angle is different from the first angle and the second angle. Principal moments of inertia for a bone in the subject are computed based on the first image data, the second image data and the third image data. The techniques allow high-precision, high-resolution dual-energy x-ray attenuation images to be used for computing principal moments of inertia and strength moduli of individual bones, plus risk of injury and changes in risk of injury to a patient.

  8. Manipulation of Muscle Creatine and Glycogen Changes Dual X-ray Absorptiometry Estimates of Body Composition.

    PubMed

    Bone, Julia L; Ross, Megan L; Tomcik, Kristyen A; Jeacocke, Nikki A; Hopkins, Will G; Burke, Louise M

    2017-05-01

    Standardizing a dual x-ray absorptiometry (DXA) protocol is thought to provide a reliable measurement of body composition. We investigated the effects of manipulating muscle glycogen and creatine content independently and additively on DXA estimates of lean mass. Eighteen well-trained male cyclists undertook a parallel group application of creatine loading (n = 9) (20 g·d for 5 d loading; 3 g·d maintenance) or placebo (n = 9) with crossover application of glycogen loading (12 v 6 g·kg BM per day for 48 h) as part of a larger study involving a glycogen-depleting exercise protocol. Body composition, total body water, muscle glycogen and creatine content were assessed via DXA, bioelectrical impedance spectroscopy and standard biopsy techniques. Changes in the mean were assessed using the following effect-size scale: >0.2 small, >0.6, moderate, >1.2 large and compared with the threshold for the smallest worthwhile effect of the treatment. Glycogen loading, both with and without creatine loading, resulted in substantial increases in estimates of lean body mass (mean ± SD; 3.0% ± 0.7% and 2.0% ± 0.9%) and leg lean mass (3.1% ± 1.8% and 2.6% ± 1.0%) respectively. A substantial decrease in leg lean mass was observed after the glycogen depleting condition (-1.4% ± 1.6%). Total body water showed substantial increases after glycogen loading (2.3% ± 2.3%), creatine loading (1.4% ± 1.9%) and the combined treatment (2.3% ± 1.1%). Changes in muscle metabolites and water content alter DXA estimates of lean mass during periods in which minimal change in muscle protein mass is likely. This information needs to be considered in interpreting the results of DXA-derived estimates of body composition in athletes.

  9. Provider Distribution Changes in Dual-Energy X-Ray Absorptiometry in the Medicare Population Over the Past Decade.

    PubMed

    Intenzo, Charles M; Parker, Laurence; Levin, David C; Kim, Sung M; Rao, Vijay M

    2016-01-01

    Both radiologists as well as nonimaging physicians perform dual-energy X-ray absorptiometry (DXA) imaging in the United States. This study aims to compare provider distribution between these physician groups on the Medicare population, which is the predominant age group of patients evaluated by this imaging procedure. Using the 2 relevant Current Procedural Terminology, Fourth Edition codes for DXA scans, source data were obtained from the CMS Physician Supplier Procedure Summary Master Files from 2003 through 2013. DXA scan procedure volumes for radiologists and nonradiologists on Medicare patients were tabulated. Utilization rates were calculated. From 2003 to 2013, the total number of DXA scans performed on Medicare patients decreased by 2%. However, over the same period, the number of scans performed by radiologists had increased by 25% over nonimaging specialists, whose utilization had declined by approximately the same amount. From 2003 to 2013, the rate of utilization of DXA scans in the Medicare fee-for-service population declined somewhat. However, radiologists continue to gain market share from other specialists and now predominate in this type of imaging by a substantial margin. Copyright © 2016 International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.

  10. Predicting skeletal muscle mass from dual-energy X-ray absorptiometry in Japanese prepubertal children.

    PubMed

    Midorikawa, T; Ohta, M; Hikihara, Y; Torii, S; Sakamoto, S

    2017-10-01

    We aimed to develop regression-based prediction equations for estimating total and regional skeletal muscle mass (SMM) from measurements of lean soft tissue mass (LSTM) using dual-energy X-ray absorptiometry (DXA) and investigate the validity of these equations. In total, 144 healthy Japanese prepubertal children aged 6-12 years were divided into 2 groups: the model development group (62 boys and 38 girls) and the validation group (26 boys and 18 girls). Contiguous MRI images with a 1-cm slice thickness were obtained from the first cervical vertebra to the ankle joints as reference data. The SMM was calculated from the summation of the digitized cross-sectional areas. Total and regional LSTM was measured using DXA. Strong significant correlations were observed between the site-matched SMM (total, arms, trunk and legs) measured by MRI and the LSTM obtained by DXA in the model development group for both boys and girls (R 2 adj =0.86-0.97, P<0.01, standard error of the estimate (SEE)=0.08-0.44 kg). When these SMM prediction equations were applied to the validation group, the measured total (boys 9.47±2.21 kg; girls 8.18±2.62 kg) and regional SMM were very similar to the predicted values for both boys (total SMM 9.40±2.39 kg) and girls (total SMM 8.17±2.57 kg). The results of the Bland-Altman analysis for the validation group did not indicate any bias for either boys or girls with the exception of the arm region for the girls. These results suggest that the DXA-derived prediction equations are precise and accurate for the estimation of total and regional SMM in Japanese prepubertal boys and girls.

  11. [Comparison BMC assessed by dual-energy X-ray absorptiometry and multi-frequency bioelectrical impedance in Chinese overweight and obesity adults].

    PubMed

    Wang, Zhenghe; Fu, Lianguo; Yang, Yide; Wang, Shuo; Ma, Jun

    2016-05-01

    To compare consistency of Body Mineral Content (BMC, kg) assessed by Multi-frequency Bioelectrical Impedance Analysis ( MF-BIA) and Dual Energy X-ray Absorptiometry (DXA) measurement, providing evidence for MF-BIA accurate application in Chinese overweight/obese adults. A total of 1323 overweight/obesity adults aged 22-55 years were recruited voluntarily. All the subjects received the measurement of BMC both using MF-BIA and DXA. To evaluate the agreement of BMC measured by MF-BIA and DXA using interclass correlation coefficients (ICC), then establish correction prediction models. The mean difference of BMC between two methods was significant different with 0, overweight male subgroup was 0.28 kg, and 0.38 kg for obesity male, 0.24 kg for overweight female and 0.36 kg for obesity female, respectively (P < 0.05). The ICC of BMC between MF-BIA and DXA measurement were statistically significant in all subgroups (P < 0.01). The ICC for overweight male subgroup was 0.787, 0.796 for obesity male, 0.741 for overweight female and 0.788 for obesity female, respectively. Correction prediction model: overweight male population: BMC (DXA method) = -0.297 + 1.005 x BMC (MF-BIA method). Obese male population: BMC (DXA method) =0.302 + 0.799 x BMC (MF-BIA method). Overweight female groups: BMC (DXA method) = 0.780 + 0.598 x BMC (MF-BIA method). Obese female group: BMC (DXA method) = 0.755 + 0.597 x BMC (MF-BIA method). Upon examination, correction prediction models were better. Co The correlation and agreement of BMC measured by BIA and DXA are weak in Chinese overweight/obese adults. Therefore, consideration should be given to BMC measured by BIA method in Chinese overweight/obese adults. It should be corrected or adjusted to reduce errors compared with DXA method.

  12. Is bone mineral density measurement using dual-energy X-ray absorptiometry affected by gamma rays?

    PubMed

    Xie, Liang-Jun; Li, Jian-Fang; Zeng, Feng-Wei; Jiang, Hang; Cheng, Mu-Hua; Chen, Yi

    2013-01-01

    The objective of this study was to determine whether the gamma rays emitted from the radionuclide effect bone mineral density (BMD) measurement. Nine subjects (mean age: 56 ± 17.96 yr) scheduled for bone scanning underwent BMD measurement using dual-energy X-ray absorptiometry (DXA) (Hologic/Discovery A) before and 1, 2, and 4 h after injection of technetium-99m-methylene diphosphonate (99mTc-MDP). Ten subjects (mean age: 41 ± 15.47 yr) scheduled for therapy of differentiated thyroid carcinoma with iodine-131 underwent BMD measurement before and 2 h after therapeutic radionuclide administration. All patients were given whole body BMD measurement, including head, arm, ribs, lumbar spine, pelvis, and leg sites. Besides, patients who referred to radioiodine therapy were given total hip and femoral neck BMD measurement as well. No statistically significant changes in BMD values were detected after 99mTc-MDP and iodine-131 administration for all measurement sites (p > 0.05), and individual difference of BMD before and after radionuclide imaging or therapy was less than the least significant change in lumbar spine, total hip, and femoral neck. In conclusion, BMD measurements are not influenced by the gamma rays emitted from technetium-99m and iodine-131. DXA bone densitometry may be performed simultaneously with bone scanning and radioiodine therapy. Copyright © 2013 The International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.

  13. Trunk density profile estimates from dual X-ray absorptiometry.

    PubMed

    Wicke, Jason; Dumas, Geneviève A; Costigan, Patrick A

    2008-01-01

    Accurate body segment parameters are necessary to estimate joint loads when using biomechanical models. Geometric methods can provide individualized data for these models but the accuracy of the geometric methods depends on accurate segment density estimates. The trunk, which is important in many biomechanical models, has the largest variability in density along its length. Therefore, the objectives of this study were to: (1) develop a new method for modeling trunk density profiles based on dual X-ray absorptiometry (DXA) and (2) develop a trunk density function for college-aged females and males that can be used in geometric methods. To this end, the density profiles of 25 females and 24 males were determined by combining the measurements from a photogrammetric method and DXA readings. A discrete Fourier transformation was then used to develop the density functions for each sex. The individual density and average density profiles compare well with the literature. There were distinct differences between the profiles of two of participants (one female and one male), and the average for their sex. It is believed that the variations in these two participants' density profiles were a result of the amount and distribution of fat they possessed. Further studies are needed to support this possibility. The new density functions eliminate the uniform density assumption associated with some geometric models thus providing more accurate trunk segment parameter estimates. In turn, more accurate moments and forces can be estimated for the kinetic analyses of certain human movements.

  14. Longitudinal DXA studies: minimum scanning interval for pediatric assessment of body fat

    USDA-ARS?s Scientific Manuscript database

    The increased prevalence of obesity in the United States has led to the increased use of Dual-energy X-ray absorptiometry (DXA) for assessment of body fat (TBF). The importance of early intervention has focused attention on pediatric populations. We used DXA precision analyses to determine suitable ...

  15. Body composition in male elite athletes, comparison of bioelectrical impedance spectroscopy with dual energy X-ray absorptiometry

    PubMed Central

    Svantesson, Ulla; Zander, Martina; Klingberg, Sofia; Slinde, Frode

    2008-01-01

    Background The aim of this study was to compare body composition results from bioelectrical spectroscopy (BIS) with results from dual energy X-ray absorptiometry (DXA) in a population of male elite athletes. Body composition was assessed using DXA (Lunar Prodigy, GE Lunar Corp., Madison, USA) and BIS (Hydra 4200, Xitron Technologies Inc, San Diego, California, USA) at the same occasion. Agreement between methods was assessed using paired t-tests and agreement-plots. Results Thirty-three male elite athletes (soccer and ice hockey) were included in the study. The results showed that BIS underestimates the proportion of fat mass by 4.6% points in the ice hockey players. In soccer players the BIS resulted in a lower mean fat mass by 1.1% points. Agreement between the methods at the individual level was highly variable. Conclusion Body composition results assessed by BIS in elite athletes should be interpreted with caution, especially in individual subjects. BIS may present values of fat mass that is either higher or lower than fat mass assessed by DXA, independent of true fat content of the individual. PMID:18211680

  16. Longitudinal DXA Studies: Minimum scanning interval for pediatric assessment of body fat

    USDA-ARS?s Scientific Manuscript database

    The increased prevalence of obesity in the United States, has led to the increased use of dual-energy X-ray absorptiometry (DXA) for assessment of body fat mass (TBF) in pediatric populations. We examined DXA precision, in order to determine suitable scanning intervals for the measurement of change...

  17. Fat-free mass prediction equations for bioelectric impedance analysis compared to dual energy X-ray absorptiometry in obese adolescents: a validation study.

    PubMed

    Hofsteenge, Geesje H; Chinapaw, Mai J M; Weijs, Peter J M

    2015-10-15

    In clinical practice, patient friendly methods to assess body composition in obese adolescents are needed. Therefore, the bioelectrical impedance analysis (BIA) related fat-free mass (FFM) prediction equations (FFM-BIA) were evaluated in obese adolescents (age 11-18 years) compared to FFM measured by dual-energy x-ray absorptiometry (FFM-DXA) and a new population specific FFM-BIA equation is developed. After an overnight fast, the subjects attended the outpatient clinic. After measuring height and weight, a full body scan by dual-energy x-ray absorptiometry (DXA) and a BIA measurement was performed. Thirteen predictive FFM-BIA equations based on weight, height, age, resistance, reactance and/or impedance were systematically selected and compared to FFM-DXA. Accuracy of FFM-BIA equations was evaluated by the percentage adolescents predicted within 5% of FFM-DXA measured, the mean percentage difference between predicted and measured values (bias) and the Root Mean Squared prediction Error (RMSE). Multiple linear regression was conducted to develop a new BIA equation. Validation was based on 103 adolescents (60% girls), age 14.5 (sd1.7) years, weight 94.1 (sd15.6) kg and FFM-DXA of 56.1 (sd9.8) kg. The percentage accurate estimations varied between equations from 0 to 68%; bias ranged from -29.3 to +36.3% and RMSE ranged from 2.8 to 12.4 kg. An alternative prediction equation was developed: FFM = 0.527 * H(cm)(2)/Imp + 0.306 * weight - 1.862 (R(2) = 0.92, SEE = 2.85 kg). Percentage accurate prediction was 76%. Compared to DXA, the Gray equation underestimated the FFM with 0.4 kg (55.7 ± 8.3), had an RMSE of 3.2 kg, 63% accurate prediction and the smallest bias of (-0.1%). When split by sex, the Gray equation had the narrowest range in accurate predictions, bias, and RMSE. For the assessment of FFM with BIA, the Gray-FFM equation appears to be the most accurate, but 63% is still not at an acceptable accuracy level for obese adolescents. The new equation appears to

  18. Prediction of percent body fat in adult males using dual energy x-ray absorptiometry, skinfolds, and hydrostatic weighing.

    PubMed

    Clark, R R; Kuta, J M; Sullivan, J C

    1993-04-01

    The purpose of this study was to compare the prediction of percent body fat (%FAT) by dual energy x-ray absorptiometry (DXA), skinfolds (SF), and hydrostatic weighing (HW) in adult males. Subjects were 35 adult male Caucasians (mean +/- SD; age: 39.1 +/- 14.0 yr, height: 180.6 +/- 5.3 cm, weight: 81.0 +/- 11.1 kg). %FAT, determined by HW with residual volume determined via O2 dilution, served as the criterion. DXA %FAT was determined by the Norland XR-26 (XR-26) bone densitometer and by the SF equations of Jackson and Pollock (JP) (1978), and Lohman (LOH) (1981). Criterion referenced validation included analyzing mean (+/- SD) %FAT values using a one-way ANOVA for significance, comparison of mean differences (MD), correlations (r), standard error of estimates (SEE), and total errors (TE). Significant differences were found between means of each method. The r (0.91) and SEE (3.0 %FAT) for DXA compare favorably with the established SF methods of JP and LOH for predicting %FAT; however, DXA demonstrated the largest MD (3.9 %FAT) and TE (5.2 %FAT). Regression analysis yields HW = 0.79* DXA + 0.56. The results do not support earlier research that found no significant difference between HW and DXA %FAT in males. The study suggests the density of the fat-free body (DFFB) is not constant, and that the variation in bone mineral content affects the DFFB, which contributes to the differences between DXA and HW %FAT. We recommend further research to identify inconsistencies between manufacturers of DXA equipment in prediction of %FAT in males.

  19. Prediction of appendicular skeletal and fat mass in children: excellent concordance of dual-energy X-ray absorptiometry and magnetic resonance imaging.

    PubMed

    Bridge, Pascale; Pocock, Nicholas A; Nguyen, Tuan; Munns, Craig; Cowell, Christopher T; Thompson, Martin W

    2009-09-01

    Body composition studies in children have great potential to help understand the aetiology and evolution of acute and chronic. diseases. To validate appendicular lean soft tissue mass (LSTM) and fat mass (FM) measured using dual energy X-ray absorptiometry (DXA), with magnetic resonance imaging (MRI) as the reference standard, in healthy peri-pubertal adolescents. Peri-pubertal Caucasian children (n = 74) aged 11-14 years were evaluated. DXA LSTM and FM of the mid third femur were measured and skeletal muscle mass (SM) and FM of the same region were measured on the same day by MRI. There was a strong correlation between MRI SM and DXA LSTM (r2 = 0.98, index of concordance [C] = 0.91). DXA estimation of LSTM exceeded MRI SM by a mean of 189 g, from 6-371 g (p < 0.0001). The discordance between DXA and MRI significantly increased with the absolute value (r = 0.27; p = 0.024). FM was highly correlated (r = 0.98) with a high index of concordance (C = 0.97). This study validates the use of DXA in LSTM measurement in children, confirming its potential in clinical and research roles in paediatric diseases affecting and related to body composition.

  20. National Health and Nutrition Examination Survey whole-body dual-energy X-ray absorptiometry reference data for GE Lunar systems.

    PubMed

    Fan, Bo; Shepherd, John A; Levine, Michael A; Steinberg, Dee; Wacker, Wynn; Barden, Howard S; Ergun, David; Wu, Xin P

    2014-01-01

    The National Health and Nutrition Examination Survey (NHANES 1999-2004) includes adult and pediatric comparisons for total body bone and body composition results. Because dual-energy x-ray absorptiometry (DXA) measurements from different manufacturers are not standardized, NHANES reference values currently are applicable only to a single make and model of Hologic DXA system. The purpose of this study was to derive body composition reference curves for GE Healthcare Lunar DXA systems. Published values from the NHANES 1999-2004 survey were acquired from the Centers for Disease Control and Prevention website. Using previously reported cross-calibration equations between Hologic and GE-Lunar, we converted the total body and regional bone and soft-tissue measurements from NHANES 1999-2004 to GE-Lunar values. The LMS (LmsChartMaker Pro Version 3.5) curve fitting method was used to generate GE-Lunar reference curves. Separate curves were generated for each sex and ethnicity. The reference curves were also divided into pediatric (≤20 years old) and adult (>20 years old) groups. Adult reference curves were derived as a function of age. Additional relationships of pediatric DXA values were derived as a function of height, lean mass, and bone area. Robustness was tested between Hologic and GE-Lunar Z-score values. The NHANES 1999-2004 survey included a sample of 20,672 participants' (9630 female) DXA scans. A total of 8056 participants were younger than 20 yr and were included in the pediatric reference data set. Participants enrolled in the study who weighed more than 136 kg (over scanner table limit) were excluded. The average Z-scores comparing the new GE-Lunar reference curves are close to zero, and the standard deviation of the Z-scores are close to one for all variables. As expected, all measurements on the GE-Lunar reference curves for participants younger than 20 yr increase monotonically with age. In the adult population, most of the curves are constant at younger

  1. In vivo short-term precision of hip structure analysis variables in comparison with bone mineral density using paired dual-energy X-ray absorptiometry scans from multi-center clinical trials.

    PubMed

    Khoo, Benjamin C C; Beck, Thomas J; Qiao, Qi-Hong; Parakh, Pallav; Semanick, Lisa; Prince, Richard L; Singer, Kevin P; Price, Roger I

    2005-07-01

    Hip structural analysis (HSA) is a technique for extracting strength-related structural dimensions of bone cross-sections from two-dimensional hip scan images acquired by dual energy X-ray absorptiometry (DXA) scanners. Heretofore the precision of the method has not been thoroughly tested in the clinical setting. Using paired scans from two large clinical trials involving a range of different DXA machines, this study reports the first precision analysis of HSA variables, in comparison with that of conventional bone mineral density (BMD) on the same scans. A key HSA variable, section modulus (Z), biomechanically indicative of bone strength during bending, had a short-term precision percentage coefficient of variation (CV%) in the femoral neck of 3.4-10.1%, depending on the manufacturer or model of the DXA equipment. Cross-sectional area (CSA), a determinant of bone strength during axial loading and closely aligned with conventional DXA bone mineral content, had a range of CV% from 2.8% to 7.9%. Poorer precision was associated with inadequate inclusion of the femoral shaft or femoral head in the DXA-scanned hip region. Precision of HSA-derived BMD varied between 2.4% and 6.4%. Precision of DXA manufacturer-derived BMD varied between 1.9% and 3.4%, arising from the larger analysis region of interest (ROI). The precision of HSA variables was not generally dependent on magnitude, subject height, weight, or conventional femoral neck densitometric variables. The generally poorer precision of key HSA variables in comparison with conventional DXA-derived BMD highlights the critical roles played by correct limb repositioning and choice of an adequate and appropriately positioned ROI.

  2. Estimation of percentage body fat by dual-energy x-ray absorptiometry: evaluation by in vivo human elemental composition

    PubMed Central

    Wang, ZiMian; Heymsfield, Steven B; Chen, Zhao; Zhu, Shankuan; Pierson, Richard N

    2010-01-01

    Dual-energy x-ray absorptiometry (DXA) is widely applied for estimating body fat. The percentage of body mass as fat (%fat) is predicted from a DXA-estimated RST value defined as the ratio of soft tissue attenuation at two photon energies (e.g., 40 keV and 70 keV). Theoretically, the RST concept depends on the mass of each major element in the human body. The DXA RST values, however, have never been fully evaluated by measured human elemental composition. The present investigation evaluated the DXA RST value by the total body mass of 11 major elements and the DXA %fat by the five-component (5C) model, respectively. Six elements (i.e. C, N, Na, P, Cl and Ca) were measured by in vivo neutron activation analysis, and potassium (i.e. K) by whole-body 40K counting in 27 healthy adults. Models were developed for predicting the total body mass of four additional elements (i.e. H, O, Mg and S). The elemental content of soft tissue, after correction for bone mineral elements, was used to predict the RST values. The DXA RST values were strongly associated with the RST values predicted from elemental content (r = 0.976, P < 0.001), although there was a tendency for the elemental-predicted RST to systematically exceed the DXA-measured RST (mean ± SD, 1.389 ± 0.024 versus 1.341 ± 0.024). DXA-estimated %fat was strongly associated with 5C %fat (24.4 ± 12.0% versus 24.9 ± 11.1%, r = 0.983, P < 0.001). DXA RST evaluated by in vivo elemental composition, and the present study supports the underlying physical concept and accuracy of the DXA method for estimating %fat. PMID:20393230

  3. Estimation of percentage body fat by dual-energy x-ray absorptiometry: evaluation by in vivo human elemental composition.

    PubMed

    Wang, ZiMian; Heymsfield, Steven B; Chen, Zhao; Zhu, Shankuan; Pierson, Richard N

    2010-05-07

    Dual-energy x-ray absorptiometry (DXA) is widely applied for estimating body fat. The percentage of body mass as fat (%fat) is predicted from a DXA-estimated R(ST) value defined as the ratio of soft tissue attenuation at two photon energies (e.g., 40 keV and 70 keV). Theoretically, the R(ST) concept depends on the mass of each major element in the human body. The DXA R(ST) values, however, have never been fully evaluated by measured human elemental composition. The present investigation evaluated the DXA R(ST) value by the total body mass of 11 major elements and the DXA %fat by the five-component (5C) model, respectively. Six elements (i.e. C, N, Na, P, Cl and Ca) were measured by in vivo neutron activation analysis, and potassium (i.e. K) by whole-body (40)K counting in 27 healthy adults. Models were developed for predicting the total body mass of four additional elements (i.e. H, O, Mg and S). The elemental content of soft tissue, after correction for bone mineral elements, was used to predict the R(ST) values. The DXA R(ST) values were strongly associated with the R(ST) values predicted from elemental content (r = 0.976, P < 0.001), although there was a tendency for the elemental-predicted R(ST) to systematically exceed the DXA-measured R(ST) (mean +/- SD, 1.389 +/- 0.024 versus 1.341 +/- 0.024). DXA-estimated %fat was strongly associated with 5C %fat (24.4 +/- 12.0% versus 24.9 +/- 11.1%, r = 0.983, P < 0.001). DXA R(ST) is evaluated by in vivo elemental composition, and the present study supports the underlying physical concept and accuracy of the DXA method for estimating %fat.

  4. The use of dual-energy X-ray absorptiometry to estimate the dissected composition of lamb carcasses.

    PubMed

    Mercier, J; Pomar, C; Marcoux, M; Goulet, F; Thériault, M; Castonguay, F W

    2006-06-01

    A total of 140 male and female Dorset and Suffolk lambs were slaughtered according to four live weight classes (36-39kg, 41-44kg, 46-49kg and 51-54kg). Total tissue, fat and lean masses, and bone mineral content measured by dual-energy X-ray absorptiometry (DXA) were used to predict dissected tissue weights. The DXA total weights accurately predict half-carcasses and primal cuts weights (shoulder, leg, loin and flank) (R(2)>0.99, CVe<1.3%). The prediction of the half-carcass dissected fat percentage is weaker (R(2)=0.77, CVe=10.4%). Fatness prediction accuracy is equivalent for the shoulder, leg and loin (R(2) between 0.68 and 0.78, CVe between 10% and 13%). The R(2) obtained when predicting dissected lean content from DXA variables is 0.93 for the half-carcass and higher than 0.83 for all cuts other than flank (CVe are between 3.5% and 6.5%, except for the flank, which is 9.1%). The prediction of bone weight using the bone mineral content is not very accurate for the half-carcass, shoulder and leg (R(2): 0.48, 0.47 and 0.43; CVe: 10.2%, 12.0% and 11.6%, respectively). The situation improves, however, for the loin (R(2)=0.70, CVe=10.7%). In conclusion, DXA is an effective technology for predicting total weight and the amount of lean and fat in lamb carcasses and their primal cuts.

  5. Validation of fan beam dual energy x ray absorptiometry for body composition assessment in adults aged 18–45 years

    PubMed Central

    Norcross, J; Van Loan, M D

    2004-01-01

    Background: Pencil beam dual energy x ray absorptiometry (DXA) has been shown to provide valid estimates of body fat (%BF), but DXA fan beam technology has not been adequately tested to determine its validity. Objective: To compare %BF estimated from fan beam DXA with %BF determined using two and three compartment (2C, 3C) models. Methods: Men (n = 25) and women (n = 31), aged 18–41 years, participated in the study. Body density, from hydrostatic weighing, was used in the 2C estimate of %BF; DXA was used to determine bone mineral content (BMC) for the 3C estimate of %BF calculated using body density and BMC (3CBMC). DXA was also used to determine %BF. Analysis of variance was used to test for significant differences in %BF between sexes and among methods. Results: Women were significantly shorter, weighed less, had less fat free mass, and a higher %BF than men. No significant differences were found among methods (2C, 3CBMC, DXA) for determination of %BF in either sex. Although not significant, Bland-Altman plots showed that DXA gave higher values for %BF than the 2C and 3CBMC methods. Conclusion: DXA determination of %BF was not different from that of the 2C and 3CBMC models in this group of young adults. However, to validate fan beam DXA fully as a method for body composition assessment in a wide range of individuals and populations, comparisons are needed that use a 4C model with a measure of total body water and BMC. PMID:15273189

  6. Prenatal pesticide exposure and PON1 genotype associated with adolescent body fat distribution evaluated by dual X-ray absorptiometry (DXA).

    PubMed

    Tinggaard, J; Wohlfahrt-Veje, C; Husby, S; Christiansen, L; Skakkebaek, N E; Jensen, T K; Grandjean, P; Main, K M; Andersen, H R

    2016-07-01

    Many modern pesticides have endocrine disrupting abilities and early-life exposure may affect growth and disease risk later in life. Previously, we reported associations between prenatal pesticide exposure and higher childhood body fat content measured by anthropometry. The associations were affected by child PON1 Q192R genotype. We aimed to study whether prenatal pesticide exposure was still associated with body fat content and distribution in the children at puberty and the potential impact of both maternal and child PON1 Q192R genotype. In this prospective cohort study of 247 children born by occupationally exposed or unexposed women (greenhouse workers and controls) two follow-up examinations (age 10-15 and 11-16 years) including simple anthropometry, skinfold measurements, pubertal staging and blood sampling were performed. Total and regional fat% was determined by dual X-ray absorptiometry (DXA) at age 10-15. Prenatal pesticide exposure was associated with increased total, android, and gynoid fat percentage (DXA) at age 10-15 years after adjustment for sex, socioeconomic status, and puberty (all β = 0.5 standard deviation score (SDS) p < 0.05). Stratified by sex, the associations were significant in girls (total fat: β = 0.7 SDS, android-gynoid ratio: β = 0.1, both p < 0.05), but not in boys. Carrying the R-allele (child or mother, separately, or both) augmented the differences between exposed and unexposed children (total fat: β = 1.0 SDS, β = 0.8 SDS, p < 0.05, respectively, and β = 1.2 SDS, p < 0.01). No exposure-related differences were found if either the child or mother had the QQ wild-type. At age 11-16, exposed children tended to have a higher total fat% estimated by skinfolds than unexposed children (p = 0.06). No significant associations between prenatal exposure and body mass index or waist circumference were found. Prenatal pesticide exposure was associated with higher adolescent body fat content, including android

  7. Assessment of EchoMRI-AH versus dual-energy X-ray absorptiometry to measure human body composition.

    PubMed

    Galgani, J E; Smith, S R; Ravussin, E

    2011-09-01

    The sensitivity to detect small changes in body composition (fat mass and fat-free mass) largely depends on the precision of the instrument. We compared EchoMRI-AH and dual-energy X-ray absorptiometry (DXA) (Hologic QDR-4500A) for estimating fat mass in 301 volunteers. Body composition was evaluated in 136 males and 165 females with a large range of body mass index (BMI) (19-49 kg m(-2)) and age (19-91 years old) using DXA and EchoMRI-AH. In a subsample of 13 lean (BMI=19-25 kg m(-2)) and 21 overweight/obese (BMI>25 kg m(-2)) individuals, within-subject precision was evaluated from repeated measurements taken within 1 h (n=3) and 1 week apart (mean of three measurements taken on each day). Using Bland-Altman analysis, we compared the mean of the fat mass measurements versus the difference in fat mass measured by both instruments. We found that EchoMRI-AH quantified larger amount of fat versus DXA in non-obese (BMI<30 kg m(-2) (1.1 kg, 95% confidence interval (CI(95)):-3.7 to 6.0)) and obese (BMI ≥ 30 kg m(-2) (4.2 kg, CI(95):-1.4 to 9.8)) participants. Within-subject precision (coefficient of variation, %) in fat mass measured within 1 h was remarkably better when measured by EchoMRI-AH than DXA (<0.5 versus <1.5%, respectively; P<0.001). However, 1-week apart within-subject variability showed similar values for both instruments (<2.2%; P=0.15). EchoMRI-AH yielded greater fat mass values when compared with DXA (Hologic QDR-4500A), particularly in fatter subjects. EchoMRI-AH and DXA showed similar 1-week apart precision when fat mass was measured both in lean and overweight/obese individuals.

  8. Comparison between the air displacement method and dual energy x-ray absorptiometry for estimation of body fat.

    PubMed

    Koda, M; Ando, F; Niino, N; Tsuzuku, S; Shimokata, H

    2000-04-01

    Air displacement plethysmography (ADP) is a method for the determining percent body fat (%BF) using the two-compartment model, in which the body is partitioned into body-fat mass and fat-free mass (FFM). Although this model assumes a constant density of FFM as 1.10 g/ml, its density may depend upon the bone mineral content (BMC) and total body water (TBW) which vary with age, gender, and race/ethnicity. This study compared %BF determined from ADP (ADP%BF) with %BF obtained by dual-energy x-ray absorptiometry (DXA%BF), and also investigated the effects of BMC, TBW, and other factors on its value. The subjects were 721 female and male Japanese aged 40 to 79 years. Body density was measured by ADP and %BF was calculated using Brozek et al's equation. BMC and body-fat volume were measured using DXA, and TBW was measured by multifrequency bioelectrical impedance. A series of anthropometric measurements was taken. Although ADP%BF was highly correlated with DXA%BF (female: r = 0.89, male: r = 0.90) (p < 0.001), ADP%BF differed significantly from DXA%BF (female: -1.30 +/- 0.14% (mean +/- s.e.m.), male: 1.22 +/- 0.13%) (p < 0.001). The difference in %BF (ADP%BF-DXA%BF) was negatively associated with BMC/FFM but not with TBW/FFM in both genders. The difference in %BF was also positively correlated with waist circumference. Considering previous studies, this result may be explained by the underestimation of DXA%BF, rather than by the overestimation of ADP%BF. In conclusion, ADP may be a useful method to measure %BF. However, BMC should be taken into consideration. Furthermore, DXA%BF may be underestimated in people with large waists.

  9. Segmental Musculoskeletal Examinations using Dual-Energy X-Ray Absorptiometry (DXA): Positioning and Analysis Considerations

    PubMed Central

    Hart, Nicolas H.; Nimphius, Sophia; Spiteri, Tania; Cochrane, Jodie L.; Newton, Robert U.

    2015-01-01

    Musculoskeletal examinations provide informative and valuable quantitative insight into muscle and bone health. DXA is one mainstream tool used to accurately and reliably determine body composition components and bone mass characteristics in-vivo. Presently, whole body scan models separate the body into axial and appendicular regions, however there is a need for localised appendicular segmentation models to further examine regions of interest within the upper and lower extremities. Similarly, inconsistencies pertaining to patient positioning exist in the literature which influence measurement precision and analysis outcomes highlighting a need for standardised procedure. This paper provides standardised and reproducible: 1) positioning and analysis procedures using DXA and 2) reliable segmental examinations through descriptive appendicular boundaries. Whole-body scans were performed on forty-six (n = 46) football athletes (age: 22.9 ± 4.3 yrs; height: 1.85 ± 0.07 cm; weight: 87.4 ± 10.3 kg; body fat: 11.4 ± 4.5 %) using DXA. All segments across all scans were analysed three times by the main investigator on three separate days, and by three independent investigators a week following the original analysis. To examine intra-rater and inter-rater, between day and researcher reliability, coefficients of variation (CV) and intraclass correlation coefficients (ICC) were determined. Positioning and segmental analysis procedures presented in this study produced very high, nearly perfect intra-tester (CV ≤ 2.0%; ICC ≥ 0.988) and inter-tester (CV ≤ 2.4%; ICC ≥ 0.980) reliability, demonstrating excellent reproducibility within and between practitioners. Standardised examinations of axial and appendicular segments are necessary. Future studies aiming to quantify and report segmental analyses of the upper- and lower-body musculoskeletal properties using whole-body DXA scans are encouraged to use the patient positioning and image analysis procedures outlined in this

  10. 30years of DXA technology innovations.

    PubMed

    Glüer, Claus-C

    2017-11-01

    As the successor of Dual Photon Absorptiometry (DPA), Dual X-ray Absorptiometry (DXA) has seen 30years of continuous technological innovations. Implementation of measures for standardization and quality assurance made DXA a reliable and clinically useful approach. Its use in clinical multicenter drug studies in osteoporosis lead to general acceptance as the standard technique of bone densitometry. The limitations of DXA are well established. As a measure of areal bone mineral density (aBMD) it depends on bone size and is biased by overlaying soft tissue and calcified structures. To some extent these errors can be reduced by estimation of bone depth and/or lateral imaging. DXA based aBMD can be supplemented by additional information obtainable from DXA scans: geometric indices such as hip axis length or complex models like 2-D finite element analysis have been developed and tested. Given the drastic improvement in image quality current DXA scans can be used for Vertebral Fracture Analysis (VFA) or grading of Abdominal Aortic Calcifications. A textural measure, Trabecular Bone Score (TBS) provides independent information on fracture risk. DXA devices can also be used for assessments beyond bone density. Periprosthetic aBMD changes can be monitored to study the mechanical fitting of bone implants. Total body composition measurements are increasingly being used in studies on nutrition, obesity, and sarcopenia. 30years after its inception DXA is the undisputed standard imaging technique for the assessment of osteoporotic fracture risk with new applications beyond bone densitometry adding to its value. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Dual Energy X-Ray Absorptiometry Compared with Anthropometry in Relation to Cardio-Metabolic Risk Factors in a Young Adult Population: Is the 'Gold Standard' Tarnished?

    PubMed

    Demmer, Denise L; Beilin, Lawrence J; Hands, Beth; Burrows, Sally; Pennell, Craig E; Lye, Stephen J; Mountain, Jennifer A; Mori, Trevor A

    2016-01-01

    Assessment of adiposity using dual energy x-ray absorptiometry (DXA) has been considered more advantageous in comparison to anthropometry for predicting cardio-metabolic risk in the older population, by virtue of its ability to distinguish total and regional fat. Nonetheless, there is increasing uncertainty regarding the relative superiority of DXA and little comparative data exist in young adults. This study aimed to identify which measure of adiposity determined by either DXA or anthropometry is optimal within a range of cardio-metabolic risk factors in young adults. 1138 adults aged 20 years were assessed by DXA and standard anthropometry from the Western Australian Pregnancy Cohort (Raine) Study. Cross-sectional linear regression analyses were performed. Waist to height ratio was superior to any DXA measure with HDL-C. BMI was the superior model in relation to blood pressure than any DXA measure. Midriff fat mass (DXA) and waist circumference were comparable in relation to glucose. For all the other cardio-metabolic variables, anthropometric and DXA measures were comparable. DXA midriff fat mass compared with BMI or waist hip ratio was the superior measure for triglycerides, insulin and HOMA-IR. Although midriff fat mass (measured by DXA) was the superior measure with insulin sensitivity and triglycerides, the anthropometric measures were better or equal with various DXA measures for majority of the cardio-metabolic risk factors. Our findings suggest, clinical anthropometry is generally as useful as DXA in the evaluation of the individual cardio-metabolic risk factors in young adults.

  12. Solid anthropomorphic infant whole body DXA phantom: Design, evaluation, and multisite testing

    USDA-ARS?s Scientific Manuscript database

    Dual energy X-ray absorptiometry (DXA) requires phantoms for quality control and cross-calibration. No commercially available phantoms are designed specifically for infant whole-body scanning. We fabricated a phantom closely matching a 7-kg human infant in body habitus using PVC, nylon-mix, and poly...

  13. The reliability of dual-energy X-ray absorptiometry measurements of bone mineral density in the metatarsals.

    PubMed

    Fuller, Joel T; Archer, Jane; Buckley, Jonathan D; Tsiros, Margarita D; Thewlis, Dominic

    2016-01-01

    To investigate the reliability of a simple, efficient technique for measuring bone mineral density (BMD) in the metatarsals using dual-energy X-ray absorptiometry (DXA). BMD of the right foot of 32 trained male distance runners was measured using a DXA scanner with the foot in the plantar position. Separate regions of interest (ROI) were used to assess the BMD of each metatarsal shaft (1st-5th) for each participant. ROI analysis was repeated by the same investigator to determine within-scan intra-rater reliability and by a different investigator to determine within-scan inter-rater reliability. Repeat DXA scans were undertaken for ten participants to assess between-scan intra-rater reliability. Assessment of BMD was consistently most reliable for the first metatarsal across all domains of reliability assessed (intra-class correlation coefficient [ICC] ≥0.97; coefficient of variation [CV] ≤1.5%; limits of agreement [LOA] ≤4.2%). Reasonable levels of intra-rater reliability were also achieved for the second and fifth metatarsals (ICC ≥0.90; CV ≤4.2%; LOA ≤11.9%). Poorer levels of reliability were demonstrated for the third (ICC ≥0.64; CV ≤8.2%; LOA ≤23.6%) and fourth metatarsals (ICC ≥0.67; CV ≤9.6%; LOA ≤27.5%). BMD was greatest in the first and second metatarsals (P < 0.01). Reliable measurements of BMD were achieved for the first, second and fifth metatarsals.

  14. Dual energy X-ray absorptiometry spine scans to determine abdominal fat in post-menopausal women

    PubMed Central

    Bea, J. W.; Blew, R. M.; Going, S. B.; Hsu, C-H; Lee, M. C.; Lee, V. R.; Caan, B.J.; Kwan, M.L.; Lohman, T. G.

    2016-01-01

    Body composition may be a better predictor of chronic disease risk than body mass index (BMI) in older populations. Objectives We sought to validate spine fat fraction (%) from dual energy X-ray absorptiometry (DXA) spine scans as a proxy for total abdominal fat. Methods Total body DXA scan abdominal fat regions of interest (ROI) that have been previously validated by magnetic resonance imaging were assessed among healthy, postmenopausal women who also had antero-posterior spine scans (n=103). ROIs were 1) lumbar vertebrae L2-L4 and 2) L2-Iliac Crest (L2-IC), manually selected by two independent raters, and 3) trunk, auto-selected by DXA software. Intra-class correlation coefficients evaluated intra and inter-rater reliability on a random subset (N=25). Linear regression models, validated by bootstrapping, assessed the relationship between spine fat fraction (%) and total abdominal fat (%) ROIs. Results Mean age, BMI and total body fat were: 66.1 ± 4.8y, 25.8 ± 3.8kg/m2 and 40.0 ± 6.6%, respectively. There were no significant differences within or between raters. Linear regression models adjusted for several participant and scan characteristics were equivalent to using only BMI and spine fat fraction. The model predicted L2-L4 (Adj. R2: 0.83) and L2-IC (Adj.R2:0.84) abdominal fat (%) well; the adjusted R2 for trunk fat (%) was 0.78. Model validation demonstrated minimal over-fitting (Adj. R2: 0.82, 0.83, and 0.77 for L2-L4, L2-IC, and trunk fat respectively). Conclusions The strong correlation between spine fat fraction and DXA abdominal fat measures make it suitable for further development in post-menopausal chronic disease risk prediction models. PMID:27416964

  15. Comparison of dual-energy X-ray absorptiometry and magnetic resonance imaging-measured adipose tissue depots in HIV-infected and control subjects.

    PubMed

    Scherzer, Rebecca; Shen, Wei; Bacchetti, Peter; Kotler, Donald; Lewis, Cora E; Shlipak, Michael G; Punyanitya, Mark; Heymsfield, Steven B; Grunfeld, Carl

    2008-10-01

    Studies in persons without HIV infection have compared adipose tissue measured by dual-energy X-ray absorptiometry (DXA) and magnetic resonance imaging (MRI), but no such study has been conducted in HIV-infected (HIV+) subjects, who have a high prevalence of regional fat loss. We compared DXA- with MRI-measured trunk, leg, arm, and total fat in HIV+ and control subjects. A cross-sectional analysis was conducted in 877 HIV+ subjects and 260 control subjects in FRAM (Study of Fat Redistribution and Metabolic Change in HIV Infection), stratified by sex and HIV status. Univariate associations of DXA with MRI were strongest for total and trunk fat (r > or = 0.92) and slightly weaker for leg (r > or = 0.87) and arm (r > or = 0.71) fat. The average estimated limb fat was substantially greater for DXA than for MRI for HIV+ and control men and women (all P < 0.0001). Less of a difference was observed in trunk fat measured by DXA and MRI, but the difference was still statistically significant (P < 0.0001). Bland-Altman plots showed increasing differences and variability. Greater average limb fat in control and HIV+ subjects (both P < 0.0001) was associated with greater differences between DXA and MRI measurements. Because the control subjects had more limb fat than did the HIV+ subjects, greater amounts of fat were measured by DXA than by MRI when control subjects were compared with HIV+ subjects. More HIV+ subjects had leg fat in the bottom decile of the control subjects by DXA than by MRI (P < 0.0001). Although DXA- and MRI-measured adipose tissue depots correlate strongly in HIV+ and control subjects, differences increase as average fat increases, particularly for limb fat. DXA may estimate a higher prevalence of peripheral lipoatrophy than does MRI in HIV+ subjects.

  16. Skeletal outcomes by peripheral quantitative computed tomography and dual-energy X-ray absorptiometry in adolescent girls with anorexia nervosa

    PubMed Central

    DiVasta, A. D.; Feldman, H. A.; O’Donnell, J. M.; Long, J.; Leonard, M. B.; Gordon, C. M.

    2018-01-01

    Summary We conducted the first comparison of dual-energy X-ray absorptiometry (DXA) and peripheral quantitative computed tomography (pQCT) outcomes in adolescent girls with anorexia nervosa. We observed deficits in bone density by both tools. pQCT assessments were associated with many of the same clinical parameters as have been previously established for DXA. Introduction Adolescents with anorexia nervosa (AN) commonly exhibit bone loss, but effects on bone geometry are less clear. We compared measures obtained by DXA and pQCT in girls with AN. Methods Seventy females (age 15.5 ± 1.9 years ) with AN and 132 normal-weighted controls underwent tibial measures by pQCT including trabecular volumetric bone mineral density (vBMD) at the 3 % site, cortical vBMD and dimensions at the 38 % site, and muscle cross-sectional area (CSA) at the 66 % site. Participants with AN also underwent standard DXA measures. Independent t tests compared the pQCT results, while Pearson coefficient assessed correlations among DXA and pQCT measures. Results Trabecular vBMD Z-scores were lower in AN compared to controls (AN −0.31 ± 1.42 vs +0.11 ± 1.01, p = 0.01) and cortical vBMD Z-scores were higher (AN +0.18 ± 0.92 vs −0.50 ± 0.88, p < 0.001). Trabecular vBMD and cortical CSA Z-scores positively correlated with DXA BMD Z-scores (r range 0.57–0.82, p < 0.001). Markers of nutritional status positively correlated with Z-scores for trabecular vBMD, cortical CSA, section modulus, and muscle CSA (p < 0.04 for all). Conclusions This study is the first to compare DXA and pQCT measurements in adolescent girls with AN. We observed deficits in BMD by both DXA and pQCT. pQCT assessments correlated well with DXA bone and body composition measures and were associated with many of the same clinical parameters and disease severity markers as have been previously established for DXA. The differences in cortical vBMD merit further study. PMID:27392467

  17. Automated Reporting of DXA Studies Using a Custom-Built Computer Program.

    PubMed

    England, Joseph R; Colletti, Patrick M

    2018-06-01

    Dual-energy x-ray absorptiometry (DXA) scans are a critical population health tool and relatively simple to interpret but can be time consuming to report, often requiring manual transfer of bone mineral density and associated statistics into commercially available dictation systems. We describe here a custom-built computer program for automated reporting of DXA scans using Pydicom, an open-source package built in the Python computer language, and regular expressions to mine DICOM tags for patient information and bone mineral density statistics. This program, easy to emulate by any novice computer programmer, has doubled our efficiency at reporting DXA scans and has eliminated dictation errors.

  18. Dual energy X-ray absorptiometry spine scans to determine abdominal fat in postmenopausal women.

    PubMed

    Bea, J W; Blew, R M; Going, S B; Hsu, C-H; Lee, M C; Lee, V R; Caan, B J; Kwan, M L; Lohman, T G

    2016-11-01

    Body composition may be a better predictor of chronic disease risk than body mass index (BMI) in older populations. We sought to validate spine fat fraction (%) from dual energy X-ray absorptiometry (DXA) spine scans as a proxy for total abdominal fat. Total body DXA scan abdominal fat regions of interest (ROI) that have been previously validated by magnetic resonance imaging were assessed among healthy, postmenopausal women who also had antero-posterior spine scans (n = 103). ROIs were (1) lumbar vertebrae L2-L4 and (2) L2-Iliac Crest (L2-IC), manually selected by two independent raters, and (3) trunk, auto-selected by DXA software. Intra-class correlation coefficients evaluated intra and inter-rater reliability on a random subset (N = 25). Linear regression models, validated by bootstrapping, assessed the relationship between spine fat fraction (%) and total abdominal fat (%) ROIs. Mean age, BMI, and total body fat were 66.1 ± 4.8 y, 25.8 ± 3.8 kg/m 2 and 40.0 ± 6.6%, respectively. There were no significant differences within or between raters. Linear regression models adjusted for several participant and scan characteristics were equivalent to using only BMI and spine fat fraction. The model predicted L2-L4 (Adj. R 2 : 0.83) and L2-IC (Adj. R 2 : 0.84) abdominal fat (%) well; the adjusted R 2 for trunk fat (%) was 0.78. Model validation demonstrated minimal over-fitting (Adj. R 2 : 0.82, 0.83, and 0.77 for L2-L4, L2-IC, and trunk fat, respectively). The strong correlation between spine fat fraction and DXA abdominal fat measures make it suitable for further development in postmenopausal chronic disease risk prediction models. Am. J. Hum. Biol. 28:918-926, 2016. © 2016Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  19. In situ femoral dual-energy X-ray absorptiometry related to ash weight, bone size and density, and its relationship with mechanical failure loads of the proximal femur.

    PubMed

    Lochmüller, E M; Miller, P; Bürklein, D; Wehr, U; Rambeck, W; Eckstein, F

    2000-01-01

    The objective of this study was to directly compare in situ femoral dual-energy X-ray absorptiometry (DXA) and in vitro chemical analysis (ash weight and calcium) with mechanical failure loads of the proximal femur, and to determine the influence of bone size (volume) and density on mechanical failure and DXA-derived areal bone mineral density (BMD, in g/cm2). We performed femoral DXA in 52 fixed cadavers (age 82.1 +/- 9.7 years; 30 male, 22 female) with intact skin and soft tissues. The femora were then excised, mechanically loaded to failure in a stance phase configuration, their volume measured with a water displacement method (proximal neck to lesser trochanter), and the ash weight and calcium content of this region determined by chemical analysis. The correlation coefficient between the bone mineral content (measured in situ with DXA) and the ash weight was r = 0.87 (standard error of the estimate = 16%), the ash weight allowing for a better prediction of femoral failure loads (r = 0.78; p < 0.01) than DXA (r = 0.67; p < 0.01). The femoral volume (r = 0.61; p < 0.01), but not the volumetric bone density (r = 0.26), was significantly associated with the failure load. The femoral bone volume had a significant impact (r = 0.35; p < 0.01) on the areal BMD (DXA), and only 63% of the variability of bone volume could be predicted (based on the basis of body height, weight and femoral projectional bone area. The results suggest that accuracy errors of femoral DXA limit the prediction of mechanical failure loads, and that the influence of bone size on areal BMD cannot be fully corrected by accounting for body height, weight and projected femoral area.

  20. Dual Energy X-Ray Absorptiometry Compared with Anthropometry in Relation to Cardio-Metabolic Risk Factors in a Young Adult Population: Is the ‘Gold Standard’ Tarnished?

    PubMed Central

    Hands, Beth; Pennell, Craig E.; Lye, Stephen J.; Mountain, Jennifer A.

    2016-01-01

    Background and Aims Assessment of adiposity using dual energy x-ray absorptiometry (DXA) has been considered more advantageous in comparison to anthropometry for predicting cardio-metabolic risk in the older population, by virtue of its ability to distinguish total and regional fat. Nonetheless, there is increasing uncertainty regarding the relative superiority of DXA and little comparative data exist in young adults. This study aimed to identify which measure of adiposity determined by either DXA or anthropometry is optimal within a range of cardio-metabolic risk factors in young adults. Methods and Results 1138 adults aged 20 years were assessed by DXA and standard anthropometry from the Western Australian Pregnancy Cohort (Raine) Study. Cross-sectional linear regression analyses were performed. Waist to height ratio was superior to any DXA measure with HDL-C. BMI was the superior model in relation to blood pressure than any DXA measure. Midriff fat mass (DXA) and waist circumference were comparable in relation to glucose. For all the other cardio-metabolic variables, anthropometric and DXA measures were comparable. DXA midriff fat mass compared with BMI or waist hip ratio was the superior measure for triglycerides, insulin and HOMA-IR. Conclusion Although midriff fat mass (measured by DXA) was the superior measure with insulin sensitivity and triglycerides, the anthropometric measures were better or equal with various DXA measures for majority of the cardio-metabolic risk factors. Our findings suggest, clinical anthropometry is generally as useful as DXA in the evaluation of the individual cardio-metabolic risk factors in young adults. PMID:27622523

  1. Generalized equations for estimating DXA percent fat of diverse young women and men: The Tiger Study

    USDA-ARS?s Scientific Manuscript database

    Popular generalized equations for estimating percent body fat (BF%) developed with cross-sectional data are biased when applied to racially/ethnically diverse populations. We developed accurate anthropometric models to estimate dual-energy x-ray absorptiometry BF% (DXA-BF%) that can be generalized t...

  2. The prediction of total skeletal muscle mass in a Caucasian population - comparison of Magnetic resonance imaging (MRI) and Dual-energy X-ray absorptiometry (DXA).

    PubMed

    Geisler, Corinna; Pourhassan, Maryam; Braun, Wiebke; Schweitzer, Lisa; Müller, Manfred J

    2017-03-01

    Dual-energy X-ray (DXA) is an alternative to magnetic resonance imaging (MRI) to measure skeletal muscle mass. DXA assesses lean body mass (LBM), and MRI measures skeletal muscle mass (SMM). Kim et al. (Am J Clin Nutr 2002; 76: 378; J Appl Physiol (1985) 2004; 97: 655) developed MRI-based algorithms to estimate whole-body SMM by DXA. These algorithms were based on an ethnically mixed study population (Kim et al., Am J Clin Nutr 2002; 76: 378; J Appl Physiol (1985) 2004; 97: 655). It is unclear whether Kim's algorithms are accurate in an exclusive Caucasian population. The aim of our study was to validate Kim's equation in a Caucasian population of 346 subjects. SMM MRI was assessed using MRI, and LBM and BMC DXA were measured by DXA and fat mass (FM ADP ) by air-displacement plethysmographie (ADP). SMM MRI and predicted SMM were highly correlated (r = 0·944; P<0·05). The standard error of estimate of the regression equation was 2·4 kg. However, Bland-Altman plots showed a significant (P<0·001) systematic bias between SMM MRI (median 25·1 kg; IQ 20·2-31·1 kg) and predicted SMM (median 26·3 kg; IQ 22·6-33·0 kg), overestimating SMM by 9·8%. Multiple regression analyses showed that weight explained 4·4% of the variance in the differences between SMM MRI and predicted SMM with the major part unexplained. Kim's algorithm has a systematic unexplained bias and is not recommended in Caucasians. © 2015 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  3. Feasibility of cone beam computed tomography radiomorphometric analysis and fractal dimension in assessment of postmenopausal osteoporosis in correlation with dual X-ray absorptiometry.

    PubMed

    Mostafa, Raghdaa A; Arnout, Eman A; Abo El-Fotouh, Mona M

    The aim of the present study was to assess the feasibility of using mandibular CBCT radiomorphometric indices and box-counting fractal dimension (FD) to detect osteoporosis in post-menopausal females, compare them with the healthy control group and to correlate the findings with the bone mineral density measured by dual X-ray absorptiometry (DXA). This study consisted of 50 post-menopausal females, with age ranging from 55 to 70 years. Based on their DXA results, they were classified into osteoporotic and control groups. Mandibular CBCT radiomorphomertic indices and FD analysis were measured. Significant differences were found for the CT cortical index scores (CTCI), CT mental index (CTMI) and CT mandibular index (CTI) between the control and osteoporotic groups. The control group showed higher mean values than the osteoporotic group. For FD values, no significant differences were found between the two groups. CBCT radiomorphometric indices could be used as an adjuvant tool to refer patients at risk of osteoporosis for further assessment.

  4. Skeletal outcomes by peripheral quantitative computed tomography and dual-energy X-ray absorptiometry in adolescent girls with anorexia nervosa.

    PubMed

    DiVasta, A D; Feldman, H A; O'Donnell, J M; Long, J; Leonard, M B; Gordon, C M

    2016-12-01

    We conducted the first comparison of dual-energy X-ray absorptiometry (DXA) and peripheral quantitative computed tomography (pQCT) outcomes in adolescent girls with anorexia nervosa. We observed deficits in bone density by both tools. pQCT assessments were associated with many of the same clinical parameters as have been previously established for DXA. Adolescents with anorexia nervosa (AN) commonly exhibit bone loss, but effects on bone geometry are less clear. We compared measures obtained by DXA and pQCT in girls with AN. Seventy females (age 15.5 ± 1.9 years ) with AN and 132 normal-weighted controls underwent tibial measures by pQCT including trabecular volumetric bone mineral density (vBMD) at the 3 % site, cortical vBMD and dimensions at the 38 % site, and muscle cross-sectional area (CSA) at the 66 % site. Participants with AN also underwent standard DXA measures. Independent t tests compared the pQCT results, while Pearson coefficient assessed correlations among DXA and pQCT measures. Trabecular vBMD Z-scores were lower in AN compared to controls (AN -0.31 ± 1.42 vs +0.11 ± 1.01, p = 0.01) and cortical vBMD Z-scores were higher (AN +0.18 ± 0.92 vs -0.50 ± 0.88, p < 0.001). Trabecular vBMD and cortical CSA Z-scores positively correlated with DXA BMD Z-scores (r range 0.57-0.82, p < 0.001). Markers of nutritional status positively correlated with Z-scores for trabecular vBMD, cortical CSA, section modulus, and muscle CSA (p < 0.04 for all). This study is the first to compare DXA and pQCT measurements in adolescent girls with AN. We observed deficits in BMD by both DXA and pQCT. pQCT assessments correlated well with DXA bone and body composition measures and were associated with many of the same clinical parameters and disease severity markers as have been previously established for DXA. The differences in cortical vBMD merit further study.

  5. Assessment of volume measurement of breast cancer-related lymphedema by three methods: circumference measurement, water displacement, and dual energy X-ray absorptiometry.

    PubMed

    Gjorup, Caroline; Zerahn, Bo; Hendel, Helle W

    2010-06-01

    Following treatment for breast cancer 12%-60% develop breast cancer-related lymphedema (BCRL). There are several ways of assessing BCRL. Circumference measurement (CM) and water displacement (WD) for volume measurements (VM) are frequently used methods in practice and research, respectively. The aim of this study was to evaluate CM and WD for VM of the BCRL arm and the contralateral arm, comparing the results with regional dual energy X-ray absorptiometry (DXA). Twenty-four women with unilateral BCRL were included in the study. Blinded duplicate VM were obtained from both arms using the three methods mentioned above. CM and DXA were performed by two observers. WD was performed by a group of observers. Mean differences (d) in duplicated volumes, limits of agreement (LOA), and 95% confidence intervals (CI) were calculated for each method. The repeatability expressed as d (95% CI) between the duplicated VM of the BCRL arm and the contralateral arm was for DXA 3 ml (-6-11) and 3 ml (1-7), respectively. For CM and WD, the d (95% CI) of the BCRL arm were 107 ml (86-127) and 26 ml (-26-79), respectively and in the contralateral arm 100 ml (78-122) and -6 ml (-29-17), respectively. DXA is superior in repeatability when compared to CM and WD for VM, especially for the BCRL arm but also the contralateral arm.

  6. Estimates of volumetric bone density from projectional measurements improve the discriminatory capability of dual X-ray absorptiometry

    NASA Technical Reports Server (NTRS)

    Jergas, M.; Breitenseher, M.; Gluer, C. C.; Yu, W.; Genant, H. K.

    1995-01-01

    To determine whether estimates of volumetric bone density from projectional scans of the lumbar spine have weaker associations with height and weight and stronger associations with prevalent vertebral fractures than standard projectional bone mineral density (BMD) and bone mineral content (BMC), we obtained posteroanterior (PA) dual X-ray absorptiometry (DXA), lateral supine DXA (Hologic QDR 2000), and quantitative computed tomography (QCT, GE 9800 scanner) in 260 postmenopausal women enrolled in two trials of treatment for osteoporosis. In 223 women, all vertebral levels, i.e., L2-L4 in the DXA scan and L1-L3 in the QCT scan, could be evaluated. Fifty-five women were diagnosed as having at least one mild fracture (age 67.9 +/- 6.5 years) and 168 women did not have any fractures (age 62.3 +/- 6.9 years). We derived three estimates of "volumetric bone density" from PA DXA (BMAD, BMAD*, and BMD*) and three from paired PA and lateral DXA (WA BMD, WA BMDHol, and eVBMD). While PA BMC and PA BMD were significantly correlated with height (r = 0.49 and r = 0.28) or weight (r = 0.38 and r = 0.37), QCT and the volumetric bone density estimates from paired PA and lateral scans were not (r = -0.083 to r = 0.050). BMAD, BMAD*, and BMD* correlated with weight but not height. The associations with vertebral fracture were stronger for QCT (odds ratio [QR] = 3.17; 95% confidence interval [CI] = 1.90-5.27), eVBMD (OR = 2.87; CI 1.80-4.57), WA BMDHol (OR = 2.86; CI 1.80-4.55) and WA-BMD (OR = 2.77; CI 1.75-4.39) than for BMAD*/BMD* (OR = 2.03; CI 1.32-3.12), BMAD (OR = 1.68; CI 1.14-2.48), lateral BMD (OR = 1.88; CI 1.28-2.77), standard PA BMD (OR = 1.47; CI 1.02-2.13) or PA BMC (OR = 1.22; CI 0.86-1.74). The areas under the receiver operating characteristic (ROC) curves for QCT and all estimates of volumetric BMD were significantly higher compared with standard PA BMD and PA BMC. We conclude that, like QCT, estimates of volumetric bone density from paired PA and lateral scans are

  7. Method and apparatus for multiple-projection, dual-energy x-ray absorptiometry scanning

    NASA Technical Reports Server (NTRS)

    Feldmesser, Howard S. (Inventor); Magee, Thomas C. (Inventor); Charles, Jr., Harry K. (Inventor); Beck, Thomas J. (Inventor)

    2007-01-01

    Methods and apparatuses for advanced, multiple-projection, dual-energy X-ray absorptiometry scanning systems include combinations of a conical collimator; a high-resolution two-dimensional detector; a portable, power-capped, variable-exposure-time power supply; an exposure-time control element; calibration monitoring; a three-dimensional anti-scatter-grid; and a gantry-gantry base assembly that permits up to seven projection angles for overlapping beams. Such systems are capable of high precision bone structure measurements that can support three dimensional bone modeling and derivations of bone strength, risk of injury, and efficacy of countermeasures among other properties.

  8. The effect of hydration status on the measurement of lean tissue mass by dual-energy X-ray absorptiometry.

    PubMed

    Toomey, Clodagh M; McCormack, William G; Jakeman, Phil

    2017-03-01

    Athletes cycle between exercise and recovery. Exercise invokes changes in total body water from thermal sweating, muscle and hepatic glycogen depletion and metabolic water loss. Recovery from exercise results in rehydration, substrate repletion, and possible glycogen supercompensation. Such changes may corrupt the measurement of hydrated tissues, such as lean tissue mass (LTM), by dual-energy X-ray absorptiometry (DXA). The purpose of this study was to determine the effect of exercise and thermal dehydration and subsequent glycogen supercompensation on DXA-based measurement of body composition. Twelve active adult (18-29 years) males exercised at 70% VO 2max on a cycle ergometer in a thermal environment (30 °C) to induce a 2.5% reduction in body mass. Participants subsequently underwent a glycogen supercompensation phase, whereby a high carbohydrate diet (8-12 g/kg body mass/day) was consumed for a 48-h period. Whole-body DXA measurement was performed at baseline, following exercise and supercompensation. Following exercise, mean body mass decreased by -1.93 kg (95% CI -2.3, -1.5), while total LTM decreased by -1.69 kg (-2.4, -1.0). Supercompensation induced a mean body mass increase of 2.53 kg (2.0, 3.1) and a total LTM increase of 2.36 kg (1.8, 2.9). No change in total fat mass or bone mineral content was observed at any timepoint. Training regimens that typically induce dehydration and nutrition regimens that involve carbohydrate loading can result in apparent changes to LTM measurement by DXA. Accurate measurement of LTM in athletes requires strict observation of hydration and glycogen status to prevent manipulation of results.

  9. Assessment of regional adipose tissue depots: a DXA and CT comparison in cadavers of elderly persons.

    PubMed

    Scafoglieri, Aldo; Deklerck, Rudi; Tresignie, Jonathan; De Mey, Johan; Clarys, Jan Pieter; Bautmans, Ivan

    2013-09-01

    Since dual energy X-ray absorptiometry (DXA) cannot distinguish between different adipose tissue (AT) deposits, it remains unclear how DXA-derived body composition variables relate to anatomical tissue (sub)compartments. The aim of the present study was to compare and relate regional DXA variables with absolute tissue masses obtained by computer tomography (CT) scanning of the lower limbs in elderly persons. Eleven well-preserved white Caucasian adults (seven male and four female cadavers) with a median age of 79.0 years (ranging from 68 to 96 years) were fully scanned with DXA and CT. Separate densities of skin tissue, AT, muscle tissue and bone were obtained by hydrostatic weighing. The leg DXA-variables were significantly related (rho-values between 0.60 and 0.98, P < 0.01) to CT-derived tissue counterparts, but showed significant systematic differences except for subcutaneous AT mass (P = 0.773). After controlling for other AT depots, fat as measured by DXA (fat(DXA)) related only to intermuscular AT (rho = 0.82, P < 0.01) in males and to subcutaneous AT (rho = 0.84, P < 0.05) in females. Although significantly interrelated, DXA and CT variables should not be used interchangeably since they have different quantitative and physiological significance. Our results suggest that fat(DXA) represents different parts of AT depots in elderly men and women. Since DXA is not appropriate for assessing tissue variability cautious clinical interpretation is warranted. © 2013.

  10. Air displacement plethysmography, dual-energy X-ray absorptiometry, and total body water to evaluate body composition in preschool-age children.

    PubMed

    Crook, Tina A; Armbya, Narain; Cleves, Mario A; Badger, Thomas M; Andres, Aline

    2012-12-01

    Anthropometrics and body mass index are only proxies in the evaluation of adiposity in the pediatric population. Air displacement plethysmography technology was not available for children aged 6 months to 9 years until recently. Our study was designed to test the precision of air displacement plethysmography (ADP) in measuring body fat mass in children at ages 3 to 5 years compared with a criterion method, deuterium oxide dilution (D(2)O), which estimates total body water and a commonly used methodology, dual-energy x-ray absorptiometry (DXA). A prospective, cross-sectional cohort of 66 healthy children (35 girls) was recruited in the central Arkansas region between 2007 and 2009. Weight and height were obtained using standardized procedures. Fat mass (%) was measured using ADP, DXA, and D(2)O. Concordance correlation coefficient and Bland-Altman plots were used to investigate the precision of the ADP techniques against D(2)O and DXA in children at ages 3 to 5 years. ADP concordance correlation coefficient for fat mass was weak (0.179) when compared with D(2)O. Bland-Altman plots revealed a low accuracy and large scatter of ADP fat mass (%) results (mean=-2.5, 95% CI -20.3 to 15.4) compared with D(2)O. DXA fat mass (%) results were more consistent although DXA systematically overestimated fat mass by 4% to 5% compared with D(2)O. Compared with D(2)O, ADP does not accurately assess percent fat mass in children aged 3 to 5 years. Thus, D(2)O, DXA, or quantitative nuclear magnetic resonance may be considered better options for assessing fat mass in young children. Copyright © 2012 Academy of Nutrition and Dietetics. Published by Elsevier Inc. All rights reserved.

  11. Assessment of EchoMRI-AH versus dual-energy X-ray absorptiometry by iDXA to measure human body composition.

    PubMed

    Marlatt, K L; Greenway, F L; Ravussin, E

    2017-04-01

    Comparison of percent fat mass across different body composition analysis devices is important given variation in technology accuracy and precision, as well as the growing need for cross-validation of devices often applied across longitudinal studies. We compared EchoMRI-AH and Lunar iDXA quantification of percent body fat (PBF) in 84 adults (43M, 41F), with the mean age 39.7±15.9 years and body mass index (BMI) 26.2±5.3 kg/m 2 . PBF correlated strongly between devices (r>0.95, P<0.0001). A prediction equation was derived in half of the subjects, and the other half were used to cross-validate the proposed equation (EchoMRI-AH PBF=[(0.94 × iDXA PBF)+(0.14 × Age)+(3.3 × Female)-8.83). The mean PBF difference (predicted-measured) in the validation group was not different from 0 (diff=0.27%, 95% confidence interval: -0.42-0.96, P=0.430). Bland-Altman plots showed a bias with higher measured PBF on EchoMRI-AH versus iDXA in all 84 subjects (β=0.13, P<0.0001). The proposed prediction equation was valid in our cross-validation sample, and it has the potential to be applied across multicenter studies.

  12. Total and Segmental Body Composition Examination in Collegiate Football Players Using Multifrequency Bioelectrical Impedance Analysis and Dual X-ray Absorptiometry.

    PubMed

    Raymond, Christiana J; Dengel, Donald R; Bosch, Tyler A

    2018-03-01

    Raymond, CJ, Dengel, DR, and Bosch, TA. Total and segmental body composition examination in collegiate football players using multifrequency bioelectrical impedance analysis and dual X-ray absorptiometry. J Strength Cond Res 32(3): 772-782, 2018-The current study examined the influence of player position on the agreement between multifrequency bioelectrical impedance analysis (MfBIA) and dual X-ray absorptiometry (DXA) when assessing total and segmental percent body fat (BF%), fat mass (FM), and fat-free mass (FFM) in National Collegiate Athletic Association Division I collegiate football athletes. Forty-four male collegiate athletes (age = 19 ± 1 year; height = 1.9 ± 1.0 m; and body mass = 106.4 ± 18.8 kg) participated. Player positions included: offensive linemen (OL; n = 7), tight ends (TE; n = 4), wide receivers (WR; n = 9), defensive linemen (DL; n = 6), defensive backs (DB; n = 8), linebackers (LB; n = 6), and running backs (RB; n = 4). Total and segmental body composition measured using MfBIA were compared with values obtained using DXA. Compared with DXA, MfBIA underestimated BF% (3.0 ± 3.8%), total FM (2.5 ± 4.3 kg), arm FM (0.4 ± 0.8 kg), arm FFM (1.4 ± 0.9 kg), leg FM (2.8 ± 2.0 kg), and leg FFM (5.4 ± 2.4 kg) (all p < 0.001; arm FM p = 0.002) and overestimated total FFM (-2.4 ± 4.5 kg) (p < 0.001). Limits of agreement (LOAs) were: ±7.39% (BF%), ±8.50 kg (total FM), ±1.50 kg (arm FM), ±1.83 kg (arm FFM), ±3.83 kg (leg FM), ±4.62 kg (leg FFM), and ±8.83 kg (total FFM). No significant differences were observed between devices for trunk FM (-0.3 ± 3.0 kg; p = 0.565) and trunk FFM (0.4 ± 2.4 kg; p = 0.278), with LOAs of ±5.92 and ±4.69 kg, respectively. Player position significantly affected all between-device mean body composition measurement differences (adjusted p ≤ 0.05), with OL demonstrating the greatest effect on each variable. Therefore, MfBIA does not seem accurate in examining between-player body composition in college

  13. Comparison of resting and total energy expenditure in peritoneal dialysis patients and body composition measured by dual-energy X-ray absorptiometry.

    PubMed

    El-Kateb, S; Sridharan, S; Farrington, K; Davenport, A

    2016-11-01

    Under basal resting conditions muscle metabolism is reduced, whereas metabolism increases with physical activity. We wished to determine whether there was an association between resting energy expenditure (REE) and total energy expenditure (TEE) in peritoneal dialysis (PD) patients and lean body mass (LBM). We determined REE and TEE by recently validated equations, using doubly labelled isotopic water, and LBM by dual-energy X-ray absorptiometry (DXA) scanning. We studied 87 patients, 50 male (57.4%), 25 diabetic (28.7%), mean age 60.3±17.6 years, with a median PD treatment of 11.4 (4.7-29.5) months. The mean weight was 70.1±17.7 kg with a REE of 1509±245 kcal/day and TEE 1947±378 kcal/day. REE was associated with body size (weight r=0.78 and body mass index (BMI) r=0.72) and body composition (LBM r=0.77, lean body mass index (LBMI) r=0.76, r=0.62), all P<0.001). For TEE, there was an association with weight r=0.58, BMI r=0.49 and body composition (LBM r=0.64, LBMI (r=0.54), all P<0.001). We compared LBMI measured by DXA and that estimated by the Boer equation using anthropomorphic measurements, which overestimated and underestimated LBM for smaller patients and heavier patients, respectively. Muscle metabolism is reduced at rest and increases with physical activity. Whereas previous reports based on REE did not show any association with LBM, we found an association between both REE and TEE, using a recently validated equation derived from dialysis patients, and LBM measured by DXA scanning. Estimation of muscle mass from anthropomorphic measurements systematically overestimated LBM for small patients and conversely underestimated for heavier patients.

  14. Agreement between bioelectrical impedance and dual energy X-ray absorptiometry in assessing fat, lean and bone mass changes in adults after a lifestyle intervention.

    PubMed

    Macfarlane, Duncan J; Chan, Natalie T-Y; Tse, Michael A; Joe, Glen M

    2016-01-01

    We aimed to assess the agreement of a commercially available bioelectrical impedance analysis (BIA) device in measuring changes in fat, lean and bone mass over a 10-week lifestyle intervention, with dual energy X-ray absorptiometry (DXA) as reference. A sample of 136 volunteers (18-66 years) underwent a physical activity intervention to enhance lean mass and reduce fat mass. BIA (Tanita BC545) and DXA (Hologic Explorer) measures of whole-body composition were taken at baseline and at the end of the intervention. After an average of 74 ± 18 days intervention, DXA showed significant changes in 2 of 3 outcome variables: reduced fat mass of 0.802 ± 1.092 kg (P < 0.001), increased lean mass of 0.477 ± 0.966 kg (P < 0.001); minor non-significant increase of 0.007 ± 0.041 kg of bone mass (P = 0.052). The respective changes in BIA measures were a significant reduction of 0.486 ± 1.539 kg fat (P < 0.001), but non-significant increases of 0.084 ± 1.201 kg lean mass (P = 0.425), and 0.014 ± 0.091 kg bone (P = 0.074). Significant, but moderately weak, correlations were seen in absolute mass changes between DXA and BIA: 0.511 (fat), 0.362 (lean) and 0.172 (bone). Compared to DXA, BIA demonstrated mediocre agreement to changes in fat mass, but poor agreement to lean mass changes. BIA significantly underestimated the magnitude of changes in fat and lean mass compared to DXA.

  15. Body Fat Analysis in Predialysis Chronic Kidney Disease: Multifrequency Bioimpedance Assay and Anthropometry Compared With Dual-Energy X-Ray Absorptiometry.

    PubMed

    Ravindranath, Jayasurya; Pillai, Priyamvada P Sivan; Parameswaran, Sreejith; Kamalanathan, Sadish Kumar; Pal, Gopal Krushna

    2016-09-01

    Body composition analysis is required for accurate assessment of nutritional status in patients with predialysis chronic kidney disease (CKD). The reference method for assessing body fat is dual-energy X-ray absorptiometry (DXA), but it is relatively expensive and often not available for widespread clinical use. There is only limited data on the utility of less expensive and easily available alternatives such as multifrequency bioimpedance assay (BIA) and skinfold thickness (SFT) measurements for assessing body fat in predialysis CKD. The study intends to assess the utility of BIA and SFT in measuring body fat compared to the reference method DXA in subjects with predialysis CKD. Body composition analysis was done in 50 subjects with predialysis CKD using multifrequency BIA, SFT, and DXA. The agreement between the body fat percentages measured by reference method DXA and BIA/SFT was assessed by paired t-test, intraclass correlation coefficients (ICCs), regression, and Bland-Altman plots. Percentage of body fat measured by BIA was higher compared to the measurements by DXA, but the difference was not significant (30.44 ± 9.34 vs. 28.62 ± 9.00; P = .071). The ICC between DXA and BIA was 0.822 (confidence interval: 0.688, 0.899; P = .000). The mean values of body fat percentages measured by anthropometry (SFT) was considerably lower when compared to DXA (23.62 ± 8.18 vs. 28.62 ± 9.00; P = .000). The ICC between DXA and SFT was .851 (confidence interval: 0.739, 0.915; P = .000). Bland-Altman plots showed that BIA overestimated body fat by a mean of 1.8% (standard deviation, 6.98), whereas SFT underestimated body fat by 5% (standard deviation, 4.01). Regression plots showed a better agreement between SFT and DXA (R(2) = .79) than BIA (R(2) = .50). Overall, SFT showed better agreement with the DXA. Body mass index (BMI) showed a moderate positive correlation with body fat measured by DXA whereas serum albumin failed to show good correlation. SFT

  16. Relationship between indices of obesity obtained by anthropometry and dual-energy X-ray absorptiometry: The Fourth and Fifth Korea National Health and Nutrition Examination Survey (KNHANES IV and V, 2008-2011).

    PubMed

    Kim, Seul Gi; Ko, Ki dong; Hwang, In Cheol; Suh, Heuy Sun; Kay, Shelley; Caterson, Ian; Kim, Kyoung Kon

    2015-01-01

    Body mass index (BMI), waist circumference (WC), and even dual-energy X-ray absorptiometry (DXA) are used for obesity diagnosis. However, it is not known which DXA-derived index of obesity correlates best with BMI and/or WC and it is not clear whether such an index is accurate or not. The aim of this study is to show the relationship between anthropometric measurements (BMI, WC) and body fat indices from DXA and to determine which DXA indices are strongly related to BMI and WC. This study was based on data obtained from the Fourth and Fifth Korea National Health and Nutrition Examination Survey (KNHANES IV-V). DXA measurements were performed on survey subjects over 10 years old from July 2008 through to May 2011. Of these, 18 198 individuals, aged 19 years and older for whom DXA data were available, were included. Weighted Pearson's correlated coefficients (r) were calculated among indices, according to sex, age group and menopause, and the coefficients were compared with each other. BMI correlates most with trunk body fat mass in kg (r=0.831) and then with total body fat in kg (r=0.774, P<0.00043 for difference of r). In the older age group, BMI correlates with total body fat mass (r=0.822) better than with trunk fat mass (r=0.817, P<0.00043). WC correlates with trunk body fat mass most in both genders and all age groups (0.804≤r≤0.906). Correlations of BMI (r=0.645 for men, 0.689 for women) and WC (r=0.678 for men, 0.634 for women) to body fat percentages (%) were less robust than those to body fat mass. BMI and WC reflect trunk and total body fat in kg more than body fat percentage derived by DXA. Copyright © 2014 Asian Oceanian Association for the Study of Obesity. Published by Elsevier Ltd. All rights reserved.

  17. Quantification of trunk and android lean mass using dual energy x-ray absorptiometry compared to magnetic resonance imaging after spinal cord injury.

    PubMed

    Rankin, Kathleen C; O'Brien, Laura C; Gorgey, Ashraf S

    2018-02-20

    To determine whether dual energy x-ray absorptiometry (DXA) compared to magnetic resonance imaging (MRI) may accurately quantify trunk lean mass (LM) after chronic spinal cord injury (SCI) and to investigate the relationships between trunk LM, visceral adiposity, trunk fat mass and basal metabolic rate (BMR). Cross-sectional design and correlational analysis. Research setting in a medical center. Twenty-two men with motor complete paraplegia (n = 14; T4-T11) and tetraplegia (n = 8; C5-C7) were recruited as part of a clinical trial. Not applicable. Trunk and android LM were measured using DXA. The volume of six trunk muscle groups were then measured using MRI to quantify trunk LM-MRI. Subcutaneous and visceral adipose tissue (VAT) cross-sectional areas were also measured using MRI. After overnight fast, BMR was evaluated using indirect calorimetry. Trunk LM-DXA (24 ± 3.3 kg) and android LM-DXA (3.6 ± 0.7 kg) overestimated (P < 0.0001) trunk LM-MRI (1.7 ± 0.5 kg). Trunk LM-MRI = 0.088* log (trunk LM-DXA)-0.415; r 2 =0.29, SEE= 0.44 kg, P = 0.007. Trunk LM-MRI = 1.53* android LM-DXA + 0.126; r 2 =0.26, SEE= 0.21 kg, P = 0.018. Percentage trunk LM-MRI was inversely related to VAT (r=-0.79, P < 0.0001) and trunk fat mass (r=-0.83, P < 0.001). Only trunk LM-DXA was related to BMR (r = 0.61, P = 0.002). Persons with tetraplegia have 13% smaller trunk muscle cross-sectional areas (P = 0.036) compared to those with paraplegia. Trunk LM-DXA and android LM-DXA overestimated trunk LM-MRI. Percentage trunk LM-MRI, but not LM-DXA, was inversely related to trunk central adiposity. The findings highlight the importance of exercising trunk LM to attenuate cardio-metabolic disorders after SCI.

  18. Non-invasive methods for the determination of body and carcass composition in livestock: dual-energy X-ray absorptiometry, computed tomography, magnetic resonance imaging and ultrasound: invited review.

    PubMed

    Scholz, A M; Bünger, L; Kongsro, J; Baulain, U; Mitchell, A D

    2015-07-01

    The ability to accurately measure body or carcass composition is important for performance testing, grading and finally selection or payment of meat-producing animals. Advances especially in non-invasive techniques are mainly based on the development of electronic and computer-driven methods in order to provide objective phenotypic data. The preference for a specific technique depends on the target animal species or carcass, combined with technical and practical aspects such as accuracy, reliability, cost, portability, speed, ease of use, safety and for in vivo measurements the need for fixation or sedation. The techniques rely on specific device-driven signals, which interact with tissues in the body or carcass at the atomic or molecular level, resulting in secondary or attenuated signals detected by the instruments and analyzed quantitatively. The electromagnetic signal produced by the instrument may originate from mechanical energy such as sound waves (ultrasound - US), 'photon' radiation (X-ray-computed tomography - CT, dual-energy X-ray absorptiometry - DXA) or radio frequency waves (magnetic resonance imaging - MRI). The signals detected by the corresponding instruments are processed to measure, for example, tissue depths, areas, volumes or distributions of fat, muscle (water, protein) and partly bone or bone mineral. Among the above techniques, CT is the most accurate one followed by MRI and DXA, whereas US can be used for all sizes of farm animal species even under field conditions. CT, MRI and US can provide volume data, whereas only DXA delivers immediate whole-body composition results without (2D) image manipulation. A combination of simple US and more expensive CT, MRI or DXA might be applied for farm animal selection programs in a stepwise approach.

  19. Prediction of fat-free body mass from bioelectrical impedance and anthropometry among 3-year-old children using DXA

    PubMed Central

    Ejlerskov, Katrine T.; Jensen, Signe M.; Christensen, Line B.; Ritz, Christian; Michaelsen, Kim F.; Mølgaard, Christian

    2014-01-01

    For 3-year-old children suitable methods to estimate body composition are sparse. We aimed to develop predictive equations for estimating fat-free mass (FFM) from bioelectrical impedance (BIA) and anthropometry using dual-energy X-ray absorptiometry (DXA) as reference method using data from 99 healthy 3-year-old Danish children. Predictive equations were derived from two multiple linear regression models, a comprehensive model (height2/resistance (RI), six anthropometric measurements) and a simple model (RI, height, weight). Their uncertainty was quantified by means of 10-fold cross-validation approach. Prediction error of FFM was 3.0% for both equations (root mean square error: 360 and 356 g, respectively). The derived equations produced BIA-based prediction of FFM and FM near DXA scan results. We suggest that the predictive equations can be applied in similar population samples aged 2–4 years. The derived equations may prove useful for studies linking body composition to early risk factors and early onset of obesity. PMID:24463487

  20. Prediction of fat-free body mass from bioelectrical impedance and anthropometry among 3-year-old children using DXA.

    PubMed

    Ejlerskov, Katrine T; Jensen, Signe M; Christensen, Line B; Ritz, Christian; Michaelsen, Kim F; Mølgaard, Christian

    2014-01-27

    For 3-year-old children suitable methods to estimate body composition are sparse. We aimed to develop predictive equations for estimating fat-free mass (FFM) from bioelectrical impedance (BIA) and anthropometry using dual-energy X-ray absorptiometry (DXA) as reference method using data from 99 healthy 3-year-old Danish children. Predictive equations were derived from two multiple linear regression models, a comprehensive model (height(2)/resistance (RI), six anthropometric measurements) and a simple model (RI, height, weight). Their uncertainty was quantified by means of 10-fold cross-validation approach. Prediction error of FFM was 3.0% for both equations (root mean square error: 360 and 356 g, respectively). The derived equations produced BIA-based prediction of FFM and FM near DXA scan results. We suggest that the predictive equations can be applied in similar population samples aged 2-4 years. The derived equations may prove useful for studies linking body composition to early risk factors and early onset of obesity.

  1. Comparison of gross body fat-water magnetic resonance imaging at 3 Tesla to dual-energy X-ray absorptiometry in obese women.

    PubMed

    Silver, Heidi J; Niswender, Kevin D; Kullberg, Joel; Berglund, Johan; Johansson, Lars; Bruvold, Morten; Avison, Malcolm J; Welch, E Brian

    2013-04-01

    Improved understanding of how depot-specific adipose tissue mass predisposes to obesity-related comorbidities could yield new insights into the pathogenesis and treatment of obesity as well as metabolic benefits of weight loss. We hypothesized that three-dimensional (3D) contiguous "fat-water" MR imaging (FWMRI) covering the majority of a whole-body field of view (FOV) acquired at 3 Tesla (3T) and coupled with automated segmentation and quantification of amount, type, and distribution of adipose and lean soft tissue would show great promise in body composition methodology. Precision of adipose and lean soft tissue measurements in body and trunk regions were assessed for 3T FWMRI and compared to dual-energy X-ray absorptiometry (DXA). Anthropometric, FWMRI, and DXA measurements were obtained in 12 women with BMI 30-39.9 kg/m(2) . Test-retest results found coefficients of variation (CV) for FWMRI that were all under 3%: gross body adipose tissue (GBAT) 0.80%, total trunk adipose tissue (TTAT) 2.08%, visceral adipose tissue (VAT) 2.62%, subcutaneous adipose tissue (SAT) 2.11%, gross body lean soft tissue (GBLST) 0.60%, and total trunk lean soft tissue (TTLST) 2.43%. Concordance correlation coefficients between FWMRI and DXA were 0.978, 0.802, 0.629, and 0.400 for GBAT, TTAT, GBLST, and TTLST, respectively. While Bland-Altman plots demonstrated agreement between FWMRI and DXA for GBAT and TTAT, a negative bias existed for GBLST and TTLST measurements. Differences may be explained by the FWMRI FOV length and potential for DXA to overestimate lean soft tissue. While more development is necessary, the described 3T FWMRI method combined with fully-automated segmentation is fast (<30-min total scan and post-processing time), noninvasive, repeatable, and cost-effective. Copyright © 2012 The Obesity Society.

  2. Point-of-Care Phalangeal Bone Mineral Density Measurement Can Reduce the Need of Dual-Energy X-Ray Absorptiometry Scanning in Danish Women at Risk of Fracture.

    PubMed

    Holmberg, Teresa; Bech, Mickael; Gram, Jeppe; Hermann, Anne Pernille; Rubin, Katrine Hass; Brixen, Kim

    2016-03-01

    Identifying persons with a high risk of osteoporotic fractures remains a challenge. DXA uptake in women with elevated risk of osteoporosis seems to be depending on distance to scanning facilities. This study aimed to investigate the ability of a small portable scanner in identifying women with reduced bone mineral density (BMD), and to define triage thresholds for pre-selection. Total hip and lumbar spine BMD was measured by dual-energy X-ray absorptiometry and phalangeal BMD by radiographic absorptiometry in 121 Danish women with intermediate or high 10-year fracture probability (aged 61-81 years). Correlation between the two methods was estimated using correlation coefficient (r) and Bland-Altman plots. A moderate correlation between phalangeal BMD versus total hip (r = 0.47) and lumbar spine (r = 0.51), and an AUC on 0.80 was found. The mean difference between phalangeal T score and total hip T score/lumbar spine T score was low, and ranged from -0.26 SD to -0.31 SD depending on site and reference database used for calculation of T scores, but, large variation was seen at an individual level. When applying a triage approach approx. one-third of all DXA scan could be avoided and only 6 % of women in the low-risk group would be false negatives.

  3. Male Osteoporosis Awareness in the Elderly: an Analysis of Dual-Energy X-Ray Absorptiometry Use in Australia Between 1995 and 2015.

    PubMed

    Chen, Weiwen; Pocock, Nicholas

    Osteoporosis is commonly perceived to be a disease confined to aging females, despite ongoing educational interventions. There are few data on the temporal change of dual-energy X-ray absorptiometry (DXA) use in aging males compared to females. Australian Medicare DXA claims between 1995 and 2015 were analyzed to investigate gender differences and temporal change of DXA use in males and females aged 45-85 yr. In females aged 45-54 and 55-64 yr, there was a progressive increase in DXA claims per capita between 1995 until 2002, with little subsequent change from 2002 to 2015 in the younger group, but a slow subsequent increase in females aged 55-64 yr. In males aged 45-54 and 55-64 yr, there was a progressive increase in DXA claims per capita between 1995 and 2002 with an ongoing slow increase from 2002 to 2015. In older females and males aged 65-74, 75-84, or ≥85 yr, there was a progressive increase in DXA claims per capita between 1995 and 2002, with a slow increase thereafter until 2007. After 2007, following the introduction of Medicare eligibility for age over 70, claims per capita increased sharply in all 3 age groups, with a subsequent ongoing increase. The male : female claim ratio in all groups demonstrates low relative male DXA use, with the ratio consistently below 1.0. Following the 2007 Medicare change, the male : female ratio improved in the 65-74, 75-84, and ≥85 age groups. The rate of increase in the male : female ratio in subjects ≥85 yr was significantly greater than that in the 65-74 (p < 0.001) and 75-84 (p < 0.001) age groups. DXA use in males is consistently lower than that in females. Government funding intervention appears to have been most effective in relation to very elderly males over 85 yr but less so in relation to the age group 65-84. There is a need for improved education of health professionals about the risk of osteoporosis in males aged 65-84 yr. Copyright © 2016 International Society for

  4. Comparison of Multifrequency Bioelectrical Impedance vs. Dual-Energy X-ray Absorptiometry for Assessing Body Composition Changes After Participation in a 10-Week Resistance Training Program.

    PubMed

    Schoenfeld, Brad J; Nickerson, Brett S; Wilborn, Colin D; Urbina, Stacie L; Hayward, Sara B; Krieger, James; Aragon, Alan A; Tinsley, Grant M

    2018-06-20

    Schoenfeld, BJ, Nickerson, BS, Wilborn, CD, Urbina, SL, Hayward, SB, Krieger, J, Aragon, AA, and Tinsley, G. Comparison of multifrequency bioelectrical impedance vs. dual-energy x-ray absorptiometry for assessing body composition changes after participation in a 10-week resistance training program. J Strength Cond Res XX(X): 000-000, 2018-The purpose of this study was to assess the ability of multifrequency bioelectrical impedance analysis (MF-BIA) to determine alterations in total and segmental body composition across a 10-week resistance training (RT) program in comparison with the criterion reference dual-energy X-ray absorptiometry (DXA). Twenty-one young male volunteers (mean ± SD; age = 22.9 ± 3.0 years; height = 175.5 ± 5.9 cm; body mass = 82.9 ± 13.6 kg; body mass index = 26.9 ± 3.6) performed an RT program that included exercises for all major muscle groups. Body composition was assessed using both methods before and after the intervention; change scores were determined by subtracting pre-test values from post-test values for percent body fat ([INCREMENT]%BF), fat mass ([INCREMENT]FM), and fat-free mass ([INCREMENT]FFM). Mean changes were not significantly different when comparing MF-BIA with DXA for [INCREMENT]%BF (-1.05 vs. -1.28%), [INCREMENT]FM (-1.13 vs. -1.19 kg), and FFM (0.10 vs. 0.37 kg, respectively). Both methods showed strong agreement for [INCREMENT]%BF (r = 0.75; standard error of the estimate [SEE] = 1.15%), [INCREMENT]FM (r = 0.84; SEE 1.0 kg), and [INCREMENT]FFM (r = 0.71; SEE of 1.5 kg). The 2 methods were poor predictors of each other in regards to changes in segmental measurements. Our data indicate that MF-BIA is an acceptable alternative for tracking changes in FM and FFM during a combined diet and exercise program in young, athletic men, but segmental lean mass measurements must be interpreted with circumspection.

  5. [Particle size determination by radioisotope x-ray absorptiometry with sedimentation method].

    PubMed

    Matsui, Y; Furuta, T; Miyagawa, S

    1976-09-01

    The possibility of radioisotope X-ray absorptiometry to determine the particle size of powder in conjunction with sedimentation was investigated. The experimental accuracy was primarily determined by Cow and X-ray intensity. where Co'=weight concentration of the particle in the suspension w'=(micron/rho)l/(mu/rho)s-rhol/rhos rho; density micron/rho; mass absorption coefficient, suffix l and s indicate dispersion and particle, respectively. The radiosiotopes, Fe-55, Pu-238 and Cd-109 have high w-values over the wide range of the atomic number. However, a source of high micron value such as Fe-55 is not suitable because the optimal X-ray transmission length, Lopt is decided by the expression, micronlLopt approximately 2/(1+C'ow') by using Cd-109 AgKX-ray source, the weight size distribution of particles from the heavy elements such as PbO2 to light elements such as Al2O3 or flyash was determined.

  6. Concurrent agreement between an anthropometric model to predict thigh volume and dual-energy X-Ray absorptiometry assessment in female volleyball players aged 14-18 years.

    PubMed

    Tavares, Óscar M; Valente-Dos-Santos, João; Duarte, João P; Póvoas, Susana C; Gobbo, Luís A; Fernandes, Rômulo A; Marinho, Daniel A; Casanova, José M; Sherar, Lauren B; Courteix, Daniel; Coelho-E-Silva, Manuel J

    2016-11-24

    A variety of performance outputs are strongly determined by lower limbs volume and composition in children and adolescents. The current study aimed to examine the validity of thigh volume (TV) estimated by anthropometry in late adolescent female volleyball players. Dual-energy X-ray absorptiometry (DXA) measures were used as the reference method. Total and regional body composition was assessed with a Lunar DPX NT/Pro/MD+/Duo/Bravo scanner in a cross-sectional sample of 42 Portuguese female volleyball players aged 14-18 years (165.2 ± 0.9 cm; 61.1 ± 1.4 kg). TV was estimated with the reference method (TV-DXA) and with the anthropometric method (TV-ANTH). Agreement between procedures was assessed with Deming regression. The analysis also considered a calibration of the anthropometric approach. The equation that best predicted TV-DXA was: -0.899 + 0.876 × log 10 (body mass) + 0.113 × log 10 (TV-ANTH). This new model (NM) was validated using the predicted residual sum of squares (PRESS) method (R 2 PRESS  = 0.838). Correlation between the reference method and the NM was 0.934 (95%CI: 0.880-0.964, S y∙x  = 0.325 L). A new and accurate anthropometric method to estimate TV in adolescent female volleyball players was obtained from the equation of Jones and Pearson alongside with adjustments for body mass.

  7. Relationships among dual-energy X-ray absorptiometry (DXA), bioelectrical impedance (BIA), and ultrasound measurements of body composition of swine

    USDA-ARS?s Scientific Manuscript database

    In three separate studies (156 pigs total), DXA, BIA, and ultrasound were compared as methods for measuring live body composition of pigs at 60 and 100-110 kg BWt. DXA measured total body fat and lean content, BIA measurements of resistance (Rs) and reactance (Xc) were used to calculate total body l...

  8. Validation of a New Skinfold Prediction Equation Based on Dual-Energy X-Ray Absorptiometry

    ERIC Educational Resources Information Center

    Ball, Stephen; Cowan, Celsi; Thyfault, John; LaFontaine, Tom

    2014-01-01

    Skinfold prediction equations recommended by the American College of Sports Medicine underestimate body fat percentage. The purpose of this research was to validate an alternative equation for men created from dual energy x-ray absorptiometry. Two hundred ninety-seven males, aged 18-65, completed a skinfold assessment and dual energy x-ray…

  9. Sex- and age-specific percentiles of body composition indices for Chinese adults using dual-energy X-ray absorptiometry.

    PubMed

    Xiao, Zeyu; Guo, Bin; Gong, Jian; Tang, Yongjin; Shang, Jingjie; Cheng, Yong; Xu, Hao

    2017-10-01

    The aims of the study were to develop sex- and age-specific percentiles for lean mass index (LMI), appendicular LMI (aLMI), fat mass index (FMI), and body fat distribution indices in Chinese adults using dual-energy X-ray absorptiometry (DXA), and to compare those indices with those of other ethnicities using the US NHANES data. Whole-body and regional lean mass and fat mass (FM) were measured using DXA in 5688 healthy males (n = 1693) and females (n = 3995) aged 20-90 years. Body fat distribution indices were expressed as % fat trunk/% fat legs, trunk/appendicular FM ratio (FMR), and android/gynoid FMR. Percentile curves of LMI, aLMI, FMI, and body fat distribution indices were obtained by the Lambda-Mu-Sigma method. The aLMI and LMI were negatively associated with age, decreasing from the fifth decade for males, but were not associated with age in females. Females had more total FM than males, whereas males had greater central adiposity (% fat trunk/% fat legs ratio, trunk/appendicular FMR, and android/gynoid FMR) than females. Moreover, FMI and body fat distribution indices consistently increased with age in both sexes, especially in women. In comparison with white, black, and Mexican populations in the USA, Chinese adults had lower total FM, but had greater central adiposity (% fat trunk/% fat legs ratio and trunk/appendicular FMR). Additionally, older white and Mexican populations showed greater decreases for aLMI and LMI than their Chinese counterparts. We present the sex- and age-specific percentiles for aLMI, LMI, FMI, and body fat distribution indices by DXA in Chinese adults, which may refine the individual assessment of the nutritional status of Chinese adults.

  10. Radiographic morphometry and densitometry predict strength of cadaveric proximal humeri more reliably than age and DXA scan density.

    PubMed

    Skedros, John G; Knight, Alex N; Pitts, Todd C; O'Rourke, Peter J; Burkhead, Wayne Z

    2016-02-01

    Methods are needed for identifying poorer quality cadaver proximal humeri to ensure that they are not disproportionately segregated into experimental groups for fracture studies. We hypothesized that measurements made from radiographs of cadaveric proximal humeri are stronger predictors of fracture strength than chronological age or bone density values derived from dual-energy x-ray absorptiometry (DXA) scans. Thirty-three proximal humeri (range: 39-78 years) were analyzed for: (1) bone mineral density (BMD, g/cm(2)) using DXA, (2) bulk density (g/cm(3)) using DXA and volume displacement, (3) regional bone density in millimeters of aluminum (mmAl) using radiographs, and (4) regional mean (medial+lateral) cortical thickness and cortical index (CI) using radiographs. The bones were then fractured simulating a fall. Strongest correlations with ultimate fracture load (UFL) were: mean cortical thickness at two diaphyseal locations (r = 0.71; p < 0.001), and mean mmAl in the humeral head (r = 0.70; p < 0.001). Weaker correlations were found between UFL and DXA-BMD (r = 0.60), bulk density (r = 0.43), CI (r = 0.61), and age (r = -0.65) (p values <0.01). Analyses between UFL and the product of any two characteristics showed six combinations with r-values >0.80, but none included DXA-derived density, CI, or age. Radiographic morphometric and densitometric measurements from radiographs are therefore stronger predictors of UFL than age, CI, or DXA-derived density measurements. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  11. Which is the best cutoff of body mass index to identify obesity in female patients with rheumatoid arthritis? A study using dual energy X-ray absorptiometry body composition.

    PubMed

    Guimarães, Maria Fernanda B Resende; Pinto, Maria Raquel da Costa; Raid, Renata G Santos Couto; Andrade, Marcus Vinícius Melo de; Kakehasi, Adriana Maria

    Standard anthropometric measures used to diagnose obesity in the general population may not have the same performance in patients with rheumatoid arthritis. To determine cutoff points for body mass index (BMI) and waist circumference (WC) for detecting obesity in women with rheumatoid arthritis (RA) by comparing these standard anthropometric measures to a dual-energy X-ray absorptiometry (DXA)-based obesity criterion. Adult female patients with more than six months of diagnosis of RA underwent clinical evaluation, with anthropometric measures and body composition with DXA. Eighty two patients were included, mean age 55±10.7 years. The diagnosis of obesity in the sample was about 31.7% by BMI, 86.6% by WC and 59.8% by DXA. Considering DXA as golden standard, cutoff points were identified for anthropometric measures to better approximate DXA estimates of percent body fat: for BMI value≥25kg/m 2 was the best for definition of obesity in female patients with RA, with sensitivity of 80% and specificity of 60%. For WC, with 80% of sensitivity and 35% of specificity, the best value to detect obesity was 86cm. A large percentage of patients were obese. The traditional cutoff points used for obesity were not suitable for our sample. For this female population with established RA, BMI cutoff point of 25kg/m 2 and WC cutoff point of 86cm were the most appropriate to detect obesity. Copyright © 2016 Elsevier Editora Ltda. All rights reserved.

  12. Which is the best cutoff of body mass index to identify obesity in female patients with rheumatoid arthritis? A study using dual energy X-ray absorptiometry body composition.

    PubMed

    Guimarães, Maria Fernanda B Resende; da Costa Pinto, Maria Raquel; Raid, Renata G Santos Couto; Andrade, Marcus Vinícius Melo de; Kakehasi, Adriana Maria

    2016-02-11

    Standard anthropometric measures used to diagnose obesity in the general population may not have the same performance in patients with rheumatoid arthritis. To determine cutoff points for body mass index (BMI) and waist circumference (WC) for detecting obesity in women with rheumatoid arthritis (RA) by comparing these standard anthropometric measures to a dual-energy x-ray absorptiometry (DXA)-based obesity criterion. Adult female patients with more than six months of diagnosis of RA underwent clinical evaluation, with anthropometric measures and body composition with DXA. Eighty two patients were included, mean age 55±10.7 years. The diagnosis of obesity in the sample was about 31.7% by BMI, 86.6% by WC and 59.8% by DXA. Considering DXA as golden standard, Cutoff points were identified for anthropometric measures to better approximate DXA estimates of percent body fat: for BMI value ≥ 25kg/m 2 was the best for definition of obesity in female patients with RA, with sensitivity of 80% and specificity of 60%. For WC, with 80% of sensitivity and 35% of specificity, the best value to detect obesity was 86cm. A large percentage of patients were obese. The traditional cutoff points used for obesity were not suitable for our sample. For this female population with established RA, BMI cutoff point of 25kg/m 2 and WC cutoff point of 86cm were the most appropriate to detect obesity. Copyright © 2016 Elsevier Editora Ltda. All rights reserved.

  13. Validation of multi-frequency bioelectrical impedance analysis versus dual-energy X-ray absorptiometry to measure body fat percentage in overweight/obese Colombian adults.

    PubMed

    Ramírez-Vélez, Robinson; Tordecilla-Sanders, Alejandra; Correa-Bautista, Jorge Enrique; González-Ruíz, Katherine; González-Jiménez, Emilio; Triana-Reina, Hector Reynaldo; García-Hermoso, Antonio; Schmidt-RioValle, Jacqueline

    2018-01-01

    To verify the validity of multi-frequency bioelectrical impedance analysis (mBCA) for predicting body fat percentage (BF%) in overweight/obese adults using dual-energy X-ray absorptiometry (DXA) as the reference method. Forty-eight adults participated (54% women, mean age = 41.0 ± 7.3 years old). The Pearson's correlation coefficient was used to evaluate the correlation between BIA and BF% assessed by DXA. The concordance between BF% measured by both methods was obtained with Lin's concordance correlation coefficient and Bland-Altman difference plots. Measures of BF% were estimated as 39.0 (SD = 6.1) and 38.3 (SD = 6.5) using DXA and mBCA, respectively. The Pearson's correlation coefficient reflected a strong correlation (r =.921, P = .001). The paired t-test showed a significant mean difference between these methods for obese men BF% of -0.6 [(SD 1.95; 95% CI = -4.0 to 3.0), P =.037]. Overall, the bias of the mBCA was -0.6 [(SD 2.2; 95% CI = -5.0 to 3.7), P =.041], which indicated that the mBCA method significantly underestimated BF% in comparison to the reference method. Finally, in both genders, Lin's concordance correlation coefficient showed a strong agreement. More specifically the DXA value was ρc = 0.943 (95% CI = 0.775 to 0.950) and the mBCA value was ρc = 0.948 (95% CI = 0.778 to 0.978). Our analysis showed a strong agreement between the two methods as reflected in the range of BF%. These results show that mBCA and DXA are comparable methods for measuring body composition with higher body fat percentages. However, due to broad limits of agreement, we can only recommend mBCA for groups of populations. © 2017 Wiley Periodicals, Inc.

  14. Dual-energy X-ray absorptiometry–based body volume measurement for 4-compartment body composition123

    PubMed Central

    Wilson, Joseph P; Mulligan, Kathleen; Fan, Bo; Sherman, Jennifer L; Murphy, Elizabeth J; Tai, Viva W; Powers, Cassidy L; Marquez, Lorena; Ruiz-Barros, Viviana

    2012-01-01

    Background: Total body volume (TBV), with the exclusion of internal air voids, is necessary to quantify body composition in Lohman's 4-compartment (4C) model. Objective: This investigation sought to derive a novel, TBV measure with the use of only dual-energy X-ray absorptiometry (DXA) attenuation values for use in Lohman's 4C body composition model. Design: Pixel-specific masses and volumes were calculated from low- and high-energy attenuation values with the use of first principle conversions of mass attenuation coefficients. Pixel masses and volumes were summed to derive body mass and total body volume. As proof of concept, 11 participants were recruited to have 4C measures taken: DXA, air-displacement plethysmography (ADP), and total body water (TBW). TBV measures with the use of only DXA (DXA-volume) and ADP-volume measures were compared for each participant. To see how body composition estimates were affected by these 2 methods, we used Lohman's 4C model to quantify percentage fat measures for each participant and compared them with conventional DXA measures. Results: DXA-volume and ADP-volume measures were highly correlated (R2 = 0.99) and showed no statistically significant bias. Percentage fat by DXA volume was highly correlated with ADP-volume percentage fat measures and DXA software-reported percentage fat measures (R2 = 0.96 and R2 = 0.98, respectively) but were slightly biased. Conclusions: A novel method to calculate TBV with the use of a clinical DXA system was developed, compared against ADP as proof of principle, and used in Lohman's 4C body composition model. The DXA-volume approach eliminates many of the inherent inaccuracies associated with displacement measures for volume and, if validated in larger groups of participants, would simplify the acquisition of 4C body composition to a single DXA scan and TBW measure. PMID:22134952

  15. Bone mineral density referral for dual-energy X-ray absorptiometry using quantitative ultrasound as a prescreening tool in postmenopausal women from the general population: a cost-effectiveness analysis.

    PubMed

    Marín, F; López-Bastida, J; Díez-Pérez, A; Sacristán, J A

    2004-03-01

    The aim of our study was to assess, from the perspective of the National Health Services in Spain, the cost-effectiveness of quantitative ultrasound (QUS) as a prescreen referral method for bone mineral density (BMD) assessment by dual-energy X-ray absorptiometry (DXA) in postmenopausal women of the general population. Using femoral neck DXA and heel QUS. We evaluated 267 consecutive postmenopausal women 65 years and older and attending primary care physician offices for any medical reason. Subjects were classified as osteoporotic or nonosteoporotic (normal or osteopenic) using the WHO definition for DXA. Effectiveness was assessed in terms of the sensitivity and specificity of the referral decisions based on the QUS measurement. Local costs were estimated from health services and actual resource used. Cost-effectiveness was evaluated in terms of the expected cost per true positive osteoporotic case detected. Baseline prevalence of osteoporosis evaluated by DXA was 55.8%. The sensitivity and specificity for the diagnosis of osteoporosis by QUS using the optimal cutoff thresholds for the estimated heel BMD T-score were 97% and 94%, respectively. The average cost per osteoporotic case detected based on DXA measurement alone was 23.85 euros. The average cost per osteoporotic case detected using QUS as a prescreen was 22.00 euros. The incremental cost-effectiveness of DXA versus QUS was 114.00 euros per true positive case detected. Our results suggest that screening for osteoporosis with QUS while applying strict cufoff values in postmenopausal women of the general population is not substantially more cost-effective than DXA alone for the diagnosis of osteoporosis. However, the screening strategy with QUS may be an option in those circumstances where the diagnosis of osteoporosis is deficient because of the difficulty in accessing DXA equipment.

  16. Comparison of two bioelectrical impedance analysis devices with dual energy X-ray absorptiometry and magnetic resonance imaging in the estimation of body composition.

    PubMed

    Wang, Ji-Guang; Zhang, Yi; Chen, Han-E; Li, Yan; Cheng, Xiao-Guang; Xu, Li; Guo, Zhe; Zhao, Xing-Shan; Sato, Tetsuya; Cao, Qi-Yun; Chen, Ke-Min; Li, Biao

    2013-01-01

    We compared a 4-limb bioelectrical impedance analysis (BIA) system, HBF 359 (Omron), and a 2-limb foot-to-foot device, BC 532 (Tanita), with the standard dual energy X-ray absorptiometry (DXA) and magnetic resonance imaging (MRI) methods for the measurement of body fat percentage (BF), skeletal muscle mass percentage (SMM, or fat-free mass [FFM] for BC 532), and visceral fat level (VF). Body composition was measured in 200 healthy volunteers (100 men and 100 women, mean age 48 years) by HBF 359 and BC 532 and by DXA and MRI. The agreement was assessed by correlation analysis and paired t-test. The correlation coefficients between BIA and DXA or MRI ranged from 0.71 to 0.89 for BF, SMM, and VF by HBF 359 and from 0.77 to 0.90 for BF, FFM, and VF by BC 532 in all subjects and in men and women separately (p < 0.001 for all). Compared with DXA, HBF 359 significantly (p < 0.001) underestimated BF by -5.8% in men and -9.6% in women. Compared with MRI, the corresponding underestimatons (negative) or overestimations (positive) by HBF 359 in men and women were, respectively, +1.9% (p = 0.02) and +1.7% (p = 0.10) for SMM, and +13.3% (p < 0.001) and -8.5% (p = 0.006), for VF. The corresponding values by BC 532 in men and women were -10.7 and -6.2% for BF, -1.4 and -2.5% for FFM, and +20.4 and -18.0% for VF. The BIA devices are accurate in the estimation of body composition, especially skeletal muscle mass or FFM.

  17. Application of the World Health Organization Fracture Risk Assessment Tool to predict need for dual-energy X-ray absorptiometry scanning in postmenopausal women.

    PubMed

    Chao, An-Shine; Chen, Fang-Ping; Lin, Yu-Ching; Huang, Ting-Shuo; Fan, Chih-Ming; Yu, Yu-Wei

    2015-12-01

    To evaluate the efficacy of the World Health Organization Fracture Risk Assessment Tool, excluding bone mineral density (pre-BMD FRAX), in identifying Taiwanese postmenopausal women needing dual-energy X-ray absorptiometry (DXA) examination for further treatment. The pre-BMD FRAX score was calculated for 231 postmenopausal women who participated in public health education workshops in the local Keelung community, Taiwan. DXA scanning and vertebral fracture assessment (VFA) were arranged for women classified as intermediate or high risk for fracture using the pre-BMD FRAX fracture probability. Pre-BMD FRAX classified 26 women as intermediate risk and 37 as having high risk for fracture. Subsequent DXA scans for these 63 women showed that 36 were osteoporotic, 19 were osteopenic, and eight had normal bone density. Concurrent VFA revealed 25 spine factures in which 14 were osteoporotic, seven were osteopenic, and four had normal bone density. The efficacy of the pre-BMD FRAX score to identify those patients with low bone mass by DXA was 87.3% (55/63). When VFA was combined with BMD to identify those patients with high risk (osteopenia, osteoporosis, or spinal fracture), the efficacy of the pre-BMD score increased to 93.7% (59/63). According to the National Osteoporosis Foundation, the overall concordance between pre-BMD FRAX and BMD, expressed through the kappa index, was 0.967. Compared with the evaluation when BMD was used alone, there was a significant increase in efficacy in identifying women who need treatment using BMD plus VFA or FRAX plus BMD. Furthermore, the highest efficacy was achieved when FRAX with BMD and VFA was used. The pre-BMD FRAX score not only efficiently predicts postmenopausal patients who are potentially at risk and might require treatment but also reduces unnecessary DXA use. Concurrent VFA during DXA use increases spine fracture detection. This improvement in diagnostic efficacy allows clinicians to provide the most appropriate therapeutic

  18. Precision of dual-energy X-ray absorptiometry of the knee and heel: methodology and implications for research to reduce bone mineral loss after spinal cord injury.

    PubMed

    Peppler, W T; Kim, W J; Ethans, K; Cowley, K C

    2017-05-01

    Methodological validation of dual-energy x-ray absorptiometry (DXA)-based measures of leg bone mineral density (BMD) based on the guidelines of the International Society for Clinical Densitometry. The primary objective of this study was to determine the precision of BMD estimates at the knee and heel using the manufacturer provided DXA acquisition algorithm. The secondary objective was to determine the smallest change in DXA-based measurement of BMD that should be surpassed (least significant change (LSC)) before suggesting that a biological change has occurred in the distal femur, proximal tibia and calcaneus. Academic Research Centre, Canada. Ten people with motor-complete SCI of at least 2 years duration and 10 people from the general population volunteered to have four DXA-based measurements taken of their femur, tibia and calcaneus. BMDs for seven regions of interest (RIs) were calculated, as were short-term precision (root-mean-square (RMS) standard deviation (g cm -2 ), RMS-coefficient of variation (RMS-CV, %)) and LSC. Overall, RMS-CV values were similar between SCI (3.63-10.20%, mean=5.3%) and able-bodied (1.85-5.73%, mean=4%) cohorts, despite lower absolute BMD values at each RIs in those with SCI (35%, heel to 54%, knee; P<0.0001). Precision was highest at the calcaneus and lowest at the femur. Except at the femur, RMS-CV values were under 6%. For DXA-based estimates of BMD at the distal femur, proximal tibia and calcaneus, these precision values suggest that LSC values >10% are needed to detect differences between treated and untreated groups in studies aimed at reducing bone mineral loss after SCI.

  19. Peripheral DXA measurement around ankle joint to diagnose osteoporosis as assessed by central DXA measurement.

    PubMed

    Sung, Ki Hyuk; Choi, Young; Cho, Gyeong Hee; Chung, Chin Youb; Park, Moon Seok; Lee, Kyoung Min

    2018-02-05

    This study evaluated the correlation between central and peripheral bone mineral density (BMD) of the ankle joint, using dual-energy X-ray absorptiometry (DXA). We also investigated whether peripheral ankle BMD could be used to identify individuals who were diagnosed with osteoporosis, using central DXA. We recruited 134 volunteers aged 20-90 years who agreed to participate in this study. Central BMD of the lumbar spine and left femur, and peripheral BMD of the medial malleolus, distal tibia, lateral malleolus, and talus were measured with DXA. Among the peripheral sites of the ankle, the highest and lowest BMD were observed in the talus and lateral malleolus, respectively. All peripheral DXA measurements of the ankle joint were significantly correlated with central DXA measurements. There was a good correlation (r: 0.656-0.725) between peripheral and central BMD for the older age group (> 50 years), but fair-to-good correlation (r: 0.263-0.654) for the younger age group (< 50 years). The cut-off values for peripheral BMD of the ankle joint between osteoporosis and non-osteoporosis were 0.548 g/cm 2 (sensitivity, 89.0%; specificity, 69.0%) for the medial malleolus, 0.626 g/cm 2 (sensitivity, 83.3%; specificity, 82.8%) for the distal tibia, 0.47 g/cm 2 (sensitivity, 100.0%; specificity, 65.5%) for the lateral malleolus, and 0.973 g/cm 2 (sensitivity, 72.2%; specificity, 83.6%) for the talus (p < 0.001). This study showed good correlation between peripheral BMD around ankle joint and central BMD for older age group. Further study is required to use the ankle DXA as a valid clinical tool for the diagnosis of osteoporosis and fracture risk assessment.

  20. Correlation between bone mineral density of jaws and skeletal sites in an Iranian population using dual X-ray energy absorptiometry.

    PubMed

    Esfahanizadeh, Nasrin; Davaie, Sotoudeh; Rokn, A R; Daneshparvar, Hamid Reza; Bayat, Noushin; Khondi, Nasrin; Ajvadi, Sara; Ghandi, Mostafa

    2013-07-01

    The aim of the present study was to evaluate the relationship between the bone density of various regions of jaws and skeletal bones. A total of 110 patients with a mean age of 55.01 ± 10.77 years were selected for the purpose of the present descriptive study. Dual X-ray Energy Absorptiometry (DXA) was carried out to determine bone mineral density (BMD) of the femur and lumbar vertebrae. Then all the subjects underwent DXA of the jaw bones and BMD values were determined at four jaw regions. Data were analyzed by SPSS 16 statistical software, and the correlation between the various BMD values was determined by Pearson's correlation coefficient. The results showed that 42.7% of females had normal BMD values in the femur, and in vertebrae, 20% were osteopenic and 37.3% suffered from osteoporosis, with statistically significant differences in the BMD values of the jaws between the three above-mentioned groups (P < 0.001). There was an increasing tendency toward osteopenia and osteoporosis with age. There was a positive correlation between BMD values of the femur and lumbar vertebrae and those of all the jaw regions under study (P < 0.005). There was a negative correlation (P < 0.01) between age and the BMD values of the femur, lumbar vertebrae and anterior maxilla. The bone density of the maxilla and mandible and presence of osteoporosis or osteopenia in these bones might reflect the same problem in skeletal bones.

  1. A comparison of DXA and CT based methods for estimating the strength of the femoral neck in post-menopausal women

    PubMed Central

    Danielson, Michelle E.; Beck, Thomas J.; Karlamangla, Arun S.; Greendale, Gail A.; Atkinson, Elizabeth J.; Lian, Yinjuan; Khaled, Alia S.; Keaveny, Tony M.; Kopperdahl, David; Ruppert, Kristine; Greenspan, Susan; Vuga, Marike; Cauley, Jane A.

    2013-01-01

    Purpose Simple 2-dimensional (2D) analyses of bone strength can be done with dual energy x-ray absorptiometry (DXA) data and applied to large data sets. We compared 2D analyses to 3-dimensional (3D) finite element analyses (FEA) based on quantitative computed tomography (QCT) data. Methods 213 women participating in the Study of Women’s Health across the Nation (SWAN) received hip DXA and QCT scans. DXA BMD and femoral neck diameter and axis length were used to estimate geometry for composite bending (BSI) and compressive strength (CSI) indices. These and comparable indices computed by Hip Structure Analysis (HSA) on the same DXA data were compared to indices using QCT geometry. Simple 2D engineering simulations of a fall impacting on the greater trochanter were generated using HSA and QCT femoral neck geometry; these estimates were benchmarked to a 3D FEA of fall impact. Results DXA-derived CSI and BSI computed from BMD and by HSA correlated well with each other (R= 0.92 and 0.70) and with QCT-derived indices (R= 0.83–0.85 and 0.65–0.72). The 2D strength estimate using HSA geometry correlated well with that from QCT (R=0.76) and with the 3D FEA estimate (R=0.56). Conclusions Femoral neck geometry computed by HSA from DXA data corresponds well enough to that from QCT for an analysis of load stress in the larger SWAN data set. Geometry derived from BMD data performed nearly as well. Proximal femur breaking strength estimated from 2D DXA data is not as well correlated with that derived by a 3D FEA using QCT data. PMID:22810918

  2. Identifying Low Muscle Mass in Patients with Hip Fracture: Validation of Biolectrical Impedance Analysis and Anthropometry Compared to Dual Energy X-ray Absorptiometry.

    PubMed

    Steihaug, O M; Gjesdal, C G; Bogen, B; Ranhoff, A H

    2016-01-01

    Older hip fracture patients often have reduced muscle mass, which is associated with adverse outcomes. Dual energy X-ray absorptiometry (DXA) can determine muscle mass, but is not practical in the acute phase. We investigated bioelectrical impedance analysis (BIA) and anthropometry compared against DXA for detecting low muscle mass in hip fracture patients. This was a cross-sectional validation study at two Norwegian hospitals on 162 hip fracture patients aged ≥ 65 years. Appendicular lean mass (ALM) was determined by DXA, BIA and anthropometry 3 months after hip fracture. ALM by BIA was calculated by the Kyle, Janssen, Tengvall and Sergi equations, and ALM by anthropometry by the Heymsfield and Villani equations. The area under the receiver operating characteristic curve (AUC) was used to compare BIA and anthropometry for determining low ALM (≤5.67 kg/m2 for women and ≤7.25kg/m2 for men). Mean age was 79 years (SD 7.9), 74% were female. Mean ALM by DXA was 14.8 kg (SD 2.3) for women and 20.8 kg (SD 4.2) for men and 45% of women and 60% of men had low ALM. BIA (Kyle) in women (AUC 0.81, 95% confidence interval 0.72-0.89) and BIA (Sergi) in men (AUC 0.89, 95% CI 0.80-0.98) were best able to discriminate between low and normal ALM. Anthropometry (Heymsfield) was less accurate than BIA in women (AUC 0.64, 95% CI 0.54-0.75), and equal to BIA in men (AUC 0.72, 95% CI 0.72 0.56-0.87). BIA (Sergi, Kyle and Tengvall) and anthropometry (Heymsfield) can identify low muscle mass in hip fracture patients.

  3. Evaluation of mandibular bone mineral density using the dual-energy X-ray absorptiometry technique in edentulous subjects living in an endemic fluorosis region.

    PubMed

    Buyukkaplan, U S; Guldag, M U

    2012-07-01

    Fluoride is one of the biological trace elements with a strong affinity for osseous, cartilaginous and dental tissue. The dental and skeletal effects of high fluoride intake have already been studied in the literature, but little is known about the effects of high fluoride intake on edentulous mandibles. The purpose of this study was to evaluate the effects of high fluoride intake on mandibular bone mineral density (BMD) measured by the dual-energy X-ray absorptiometry (DXA) technique in edentulous individuals with systemic fluorosis. 32 people who were living in an endemic fluorosis area since birth and 31 people who were living in a non-endemic fluorosis area since birth (control group) participated in this study. Systemic fluorosis was diagnosed in the patients using the sialic acid (NANA)/glycosaminoglycan (GAG) ratio. The BMDs of the mandibles were determined by the DXA technique. The serum NANA/GAG ratios in the fluorosis group were significantly lower than those in the control group (p < 0.001). There was also a statistically significant difference in mandibular BMD measurements (p < 0.05) between the systemic fluorosis and control groups, as measured by the DXA technique. Mandibular body BMD measurements were higher in the fluorosis group (1.25 ± 0.24 g cm(-2)) than in the control group (1.01 ± 0.31 g cm(-2)). The results of the study showed that fluoride intake higher than the optimum level causes increased mandibular BMD in edentulous individuals. Further dose-related studies are needed to determine the effects of high fluoride intake on bony structures of the stomatognathic system.

  4. Quantitative ultrasound and dual-energy X-ray absorptiometry in the prediction of fragility fracture in men.

    PubMed

    Gonnelli, Stefano; Cepollaro, Chiara; Gennari, Luigi; Montagnani, Andrea; Caffarelli, Carla; Merlotti, Daniela; Rossi, Stefania; Cadirni, Alice; Nuti, Ranuccio

    2005-08-01

    Fragility fractures in men represent a major health problem, and this prompts a necessity for reliable tools for the identification of men at risk of fracture. In order to assess the ability of dual-energy X-ray absorptiometry (DXA) and quantitative ultrasound (QUS) in the prediction of fracture risk in men and whether their combination might be useful in a clinical setting, we studied 401 men (age range 45-82 years, mean 60.3+/-12.5), of whom 133 had osteoporotic fractures and 268 did not. In all subjects we measured bone mineral density at the lumbar spine (BMD-LS) and at the femur, calculating thereafter the standard femoral subregions: neck (BMD-FN), total hip (BMD-T), trochanter (BMD-TR), intertrochanter (BMD-ITR), and Ward's triangle (BMD-W), by DXA. We also performed ultrasound parameters at the calcaneus: speed of sound (SOS), broadband ultrasound attenuation (BUA) and Stiffness, by Achilles plus, and at the phalanxes: amplitude dependent speed of sound (AD-SoS) and the parameters of the graphic trace: bone transmission time (BTT), fast wave amplitude (FWA), signal dynamic (SDy) and ultrasound bone profile index (UBPI), by Bone Profiler. All DXA and QUS parameters, apart from FWA, were significantly (P<0.001) lower in patients with a history of fracture. BMD at the proximal femur showed the best ability in discriminating men with or without fractures. QUS at the heel showed discriminatory ability significantly better than QUS at the fingers. By logistic regression analysis, adjusted for age and BMI, BMD-T showed the best association with fragility fracture [odds ratio (OR)=3.43, 95% confidence interval (CI)=2.47-4.77]. Among QUS parameters, the highest value of the OR was shown by stiffness (OR=3.18, CI=2.27-4.48). FWA and SDy were not associated with fragility fractures in men. If DXA and QUS were combined, the prediction of the OR of fragility fracture events in men increases; in fact Stiffness was able to increase the OR when added to BMD-LS (OR=5.44, CI

  5. Upper arm anthropometrics versus DXA scan in survivors of acute respiratory distress syndrome.

    PubMed

    Chan, Kitty S; Mourtzakis, Marina; Aronson Friedman, Lisa; Dinglas, Victor D; Hough, Catherine L; Ely, E Wesley; Morris, Peter E; Hopkins, Ramona O; Needham, Dale M

    2018-04-01

    Survivors of acute respiratory distress syndrome (ARDS) experience severe muscle wasting. Upper arm anthropometrics can provide a quick, non-invasive estimate of muscle status, but its accuracy is unknown. This study examines the accuracy of upper arm percent muscle area (UAMA) with reference measures of lean mass from dual energy X-ray absorptiometry (DXA). Data are from 120 ARDS survivors participating in a multicenter national study. Receiver operating characteristic (ROC) curves, by patient sex, demonstrated that UAMA did no better than chance in discriminating low appendicular skeletal muscle mass identified using DXA findings (c-statistics, 6 months: 0.50-0.59, 12 months: 0.54-0.57). Modest correlations of UAMA with DXA measures (whole-body: r = 0.46-0.49, arm-specific: r = 0.50-0.51, p < 0.001) and Bland-Altman plots indicate poor precision. UAMA is not an appropriate screening measure for estimating muscle mass when compared to a DXA reference standard. Alternate screening measures should be evaluated in ARDS survivors.

  6. CONSENSUS STATEMENT BY THE AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS AND AMERICAN COLLEGE OF ENDOCRINOLOGY ON THE QUALITY OF DXA SCANS AND REPORTS.

    PubMed

    Licata, Angelo A; Binkley, Neil; Petak, Steven M; Camacho, Pauline M

    2018-02-01

    High-quality dual-energy X-ray absorptiometry (DXA) scans are necessary for accurate diagnosis of osteoporosis and monitoring of therapy; however, DXA scan reports may contain errors that cause confusion about diagnosis and treatment. This American Association of Clinical Endocrinologists/American College of Endocrinology consensus statement was generated to draw attention to many common technical problems affecting DXA report conclusions and provide guidance on how to address them to ensure that patients receive appropriate osteoporosis care. The DXA Writing Committee developed a consensus based on discussion and evaluation of available literature related to osteoporosis and osteodensitometry. Technical errors may include errors in scan acquisition and/or analysis, leading to incorrect diagnosis and reporting of change over time. Although the International Society for Clinical Densitometry advocates training for technologists and medical interpreters to help eliminate these problems, many lack skill in this technology. Suspicion that reports are wrong arises when clinical history is not compatible with scan interpretation (e.g., dramatic increase/decrease in a short period of time; declines in previously stable bone density after years of treatment), when different scanners are used, or when inconsistent anatomic sites are used for monitoring the response to therapy. Understanding the concept of least significant change will minimize erroneous conclusions about changes in bone density. Clinicians must develop the skills to differentiate technical problems, which confound reports, from real biological changes. We recommend that clinicians review actual scan images and data, instead of relying solely on the impression of the report, to pinpoint errors and accurately interpret DXA scan images. AACE = American Association of Clinical Endocrinologists; BMC = bone mineral content; BMD = bone mineral density; DXA = dual-energy X-ray absorptiometry; ISCD = International

  7. Dual-energy x-ray absorptiometry to measure the influence of a 16-week community-based swim training program on body fat in children and adolescents with intellectual disabilities.

    PubMed

    Casey, Amanda Faith; Rasmussen, Roy; Mackenzie, Sasho J; Glenn, Jillian

    2010-07-01

    To use dual-energy x-ray absorptiometry (DXA) to measure the effects of a 16-week community-based swim training program on percent body fat in children and adolescents with intellectual disability (ID). Convenience sample. University sport complex and exercise science laboratory. Children and adolescents (n=8; mean age +/- SD, 13.1 +/- 3.4 y), 2 girls and 6 boys with ID, of varying fat levels (11%-35%). A swim training program lasting for the duration of 16 weeks with three 1-hour sessions held at a 25-m pool each week. Assessing percent body fat at pretest and posttest through the use of DXA. After the 16-week exercise training program, we observed a 1.2% median increase in body fat percentage with a range from -0.3% to 4.5%. Wilcoxon matched-pairs signed-ranks tests suggest that these results are statistically significant (P=.039; exact). Exercise training alone proved ineffectual in reducing percent body fat in 8 children and adolescents with ID. Further research should consider implementing a combined diet and exercise program. To gauge the effectiveness of intervention programs, valid methods and complex measurement tools such as DXA should be used to assess changes in percent body fat in such a heterogeneous population. Copyright 2010 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  8. Prediction of android and gynoid body adiposity via a three-dimensional stereovision body imaging system and dual-energy x-ray absorptiometry

    PubMed Central

    Lee, Jane J.; Freeland-Graves, Jeanne H.; Pepper, M. Reese; Stanforth, Philip R.; Xu, Bugao

    2017-01-01

    Objective Current methods for measuring regional body fat are expensive and inconvenient compared to the relative cost-effectiveness and ease-of-use of a stereovision body imaging (SBI) system. The primary goal of this research is to develop prediction models for android and gynoid fat by body measurements assessed via SBI and dual-energy x-ray absorptiometry (DXA). Subsequently, mathematical equations for prediction of total and regional (trunk, leg) body adiposity were established via parameters measured by SBI and DXA. Methods A total of 121 participants were randomly assigned into primary and cross-validation groups. Body measurements were obtained via traditional anthropometrics, SBI, and DXA. Multiple regression analysis was conducted to develop mathematical equations by demographics and SBI assessed body measurements as independent variables and body adiposity (fat mass and percent fat) as dependent variables. The validity of the prediction models was evaluated by a split sample method and Bland-Altman analysis. Results The R2 of the prediction equations for fat mass and percent body fat were 93.2% and 76.4% for android, and 91.4% and 66.5% for gynoid, respectively. The limits of agreement for the fat mass and percent fat were − 0.06 ± 0.87 kg and − 0.11 ± 1.97 % for android and − 0.04 ± 1.58 kg and − 0.19 ± 4.27 % for gynoid. Prediction values for fat mass and percent fat were 94.6% and 88.9% for total body, 93.9% and 71.0% for trunk, and 92.4% and 64.1% for leg, respectively. Conclusions The three-dimensional (3D) SBI produces reliable parameters that can predict android and gynoid, as well as total and regional (trunk, leg) fat mass. PMID:25915106

  9. Prediction of Android and Gynoid Body Adiposity via a Three-dimensional Stereovision Body Imaging System and Dual-Energy X-ray Absorptiometry.

    PubMed

    Lee, Jane J; Freeland-Graves, Jeanne H; Pepper, M Reese; Stanforth, Philip R; Xu, Bugao

    2015-01-01

    Current methods for measuring regional body fat are expensive and inconvenient compared to the relative cost-effectiveness and ease of use of a stereovision body imaging (SBI) system. The primary goal of this research is to develop prediction models for android and gynoid fat by body measurements assessed via SBI and dual-energy x-ray absorptiometry (DXA). Subsequently, mathematical equations for prediction of total and regional (trunk, leg) body adiposity were established via parameters measured by SBI and DXA. A total of 121 participants were randomly assigned into primary and cross-validation groups. Body measurements were obtained via traditional anthropometrics, SBI, and DXA. Multiple regression analysis was conducted to develop mathematical equations by demographics and SBI assessed body measurements as independent variables and body adiposity (fat mass and percentage fat) as dependent variables. The validity of the prediction models was evaluated by a split sample method and Bland-Altman analysis. The R(2) of the prediction equations for fat mass and percentage body fat were 93.2% and 76.4% for android and 91.4% and 66.5% for gynoid, respectively. The limits of agreement for the fat mass and percentage fat were -0.06 ± 0.87 kg and -0.11% ± 1.97% for android and -0.04 ± 1.58 kg and -0.19% ± 4.27% for gynoid. Prediction values for fat mass and percentage fat were 94.6% and 88.9% for total body, 93.9% and 71.0% for trunk, and 92.4% and 64.1% for leg, respectively. The three-dimensional (3D) SBI produces reliable parameters that can predict android and gynoid as well as total and regional (trunk, leg) fat mass.

  10. Stature estimation equations for South Asian skeletons based on DXA scans of contemporary adults.

    PubMed

    Pomeroy, Emma; Mushrif-Tripathy, Veena; Wells, Jonathan C K; Kulkarni, Bharati; Kinra, Sanjay; Stock, Jay T

    2018-05-03

    Stature estimation from the skeleton is a classic anthropological problem, and recent years have seen the proliferation of population-specific regression equations. Many rely on the anatomical reconstruction of stature from archaeological skeletons to derive regression equations based on long bone lengths, but this requires a collection with very good preservation. In some regions, for example, South Asia, typical environmental conditions preclude the sufficient preservation of skeletal remains. Large-scale epidemiological studies that include medical imaging of the skeleton by techniques such as dual-energy X-ray absorptiometry (DXA) offer new potential datasets for developing such equations. We derived estimation equations based on known height and bone lengths measured from DXA scans from the Andhra Pradesh Children and Parents Study (Hyderabad, India). Given debates on the most appropriate regression model to use, multiple methods were compared, and the performance of the equations was tested on a published skeletal dataset of individuals with known stature. The equations have standard errors of estimates and prediction errors similar to those derived using anatomical reconstruction or from cadaveric datasets. As measured by the number of significant differences between true and estimated stature, and the prediction errors, the new equations perform as well as, and generally better than, published equations commonly used on South Asian skeletons or based on Indian cadaveric datasets. This study demonstrates the utility of DXA scans as a data source for developing stature estimation equations and offer a new set of equations for use with South Asian datasets. © 2018 Wiley Periodicals, Inc.

  11. Body Composition Comparison: Bioelectric Impedance Analysis with Dual-Energy X-Ray Absorptiometry in Adult Athletes

    ERIC Educational Resources Information Center

    Company, Joe; Ball, Stephen

    2010-01-01

    The primary purpose of this study was to investigate the accuracy of the DF50 (ImpediMed Ltd, Eight Mile Plains, Queensland, Australia) bioelectrical impedance analysis device using dual-energy x-ray absorptiometry as the criterion in two groups: endurance athletes and power athletes. The secondary purpose was to develop accurate body fat…

  12. Correlation between bone mineral density of jaws and skeletal sites in an Iranian population using dual X-ray energy absorptiometry

    PubMed Central

    Esfahanizadeh, Nasrin; Davaie, Sotoudeh; Rokn, A. R.; Daneshparvar, Hamid Reza; Bayat, Noushin; Khondi, Nasrin; Ajvadi, Sara; Ghandi, Mostafa

    2013-01-01

    Background: The aim of the present study was to evaluate the relationship between the bone density of various regions of jaws and skeletal bones. Materials and Methods: A total of 110 patients with a mean age of 55.01 ± 10.77 years were selected for the purpose of the present descriptive study. Dual X-ray Energy Absorptiometry (DXA) was carried out to determine bone mineral density (BMD) of the femur and lumbar vertebrae. Then all the subjects underwent DXA of the jaw bones and BMD values were determined at four jaw regions. Data were analyzed by SPSS 16 statistical software, and the correlation between the various BMD values was determined by Pearson's correlation coefficient. Results: The results showed that 42.7% of females had normal BMD values in the femur, and in vertebrae, 20% were osteopenic and 37.3% suffered from osteoporosis, with statistically significant differences in the BMD values of the jaws between the three above-mentioned groups (P < 0.001). There was an increasing tendency toward osteopenia and osteoporosis with age. There was a positive correlation between BMD values of the femur and lumbar vertebrae and those of all the jaw regions under study (P < 0.005). There was a negative correlation (P < 0.01) between age and the BMD values of the femur, lumbar vertebrae and anterior maxilla. Conclusion: The bone density of the maxilla and mandible and presence of osteoporosis or osteopenia in these bones might reflect the same problem in skeletal bones. PMID:24130580

  13. Trapezium Bone Density-A Comparison of Measurements by DXA and CT.

    PubMed

    Breddam Mosegaard, Sebastian; Breddam Mosegaard, Kamille; Bouteldja, Nadia; Bæk Hansen, Torben; Stilling, Maiken

    2018-01-18

    Bone density may influence the primary fixation of cementless implants, and poor bone density may increase the risk of implant failure. Before deciding on using total joint replacement as treatment in osteoarthritis of the trapeziometacarpal joint, it is valuable to determine the trapezium bone density. The aim of this study was to: (1) determine the correlation between measurements of bone mineral density of the trapezium obtained by dual-energy X-ray absorptiometry (DXA) scans by a circumference method and a new inner-ellipse method; and (2) to compare those to measurements of bone density obtained by computerized tomography (CT)-scans in Hounsfield units (HU). We included 71 hands from 59 patients with a mean age of 59 years (43-77). All patients had Eaton-Glickel stage II-IV trapeziometacarpal (TM) joint osteoarthritis, were under evaluation for trapeziometacarpal total joint replacement, and underwent DXA and CT wrist scans. There was an excellent correlation (r = 0.94) between DXA bone mineral density measures using the circumference and the inner-ellipse method. There was a moderate correlation between bone density measures obtained by DXA- and CT-scans with (r = 0.49) for the circumference method, and (r = 0.55) for the inner-ellipse method. DXA may be used in pre-operative evaluation of the trapezium bone quality, and the simpler DXA inner-ellipse measurement method can replace the DXA circumference method in estimation of bone density of the trapezium.

  14. [Body composition by dual-energy x-ray absorptiometry in women with fibromyalgia].

    PubMed

    Lobo, Márcia Maria Marques Teles; Paiva, Eduardo dos Santos; Andretta, Aline; Schieferdecker, Maria Eliana Madalozzo

    2014-01-01

    To assess body composition in women with fibromyalgia (FM) comparing to the reference value for healthy women. Cross-sectional observational analytical study, with 52 women selected with Fibromyalgia, according American College of Rheumatology (ACR, 1990) criteria. The patients were selected in Hospital de Clínicas da Universidade Federal do Paraná (HC-UFPR) and divided into two groups, 28 patients with a BMI (Body Mass Index) equal or higher (≥) than 25kg/m2 and 24 patients with BMI less or equal (≤) 24.99 kg/m2, subjected to physical examination for the count of tender points (TP) and completing the fibromyalgia impact questionnaire (FIQ). The assessment of body composition was performed by the Dual-Energy X-Ray Absorptiometry (DXA). The values of the fat mass percentage (MG %) found in the two groups were compared to the average percentage of MG by age and sex, described by Heward (2004). The mean age of the study groups was 47.8 ± 8.6 years, the FIQ score was 70.5 ± 18.6 and TP 16.2 ± 2.0. The mean BMI was 26.4 ± 4.1 kg/m2, and the amount of MG was 25.2 ± 7.8 kg and 39.5 ± 6.8%, and lean mass (LM) was 37 2 ± 3.7 kg and 60.4 ± 7.3%. In the group with BMI ≤ 25 kg/m2, the MG % was 33.8% (21.5 -42.4) and in the group with BMI ≥ 25 kg/m2 of the MG was 44.4% (37.6 -56.2). Both groups women with FM eutrophic as the overweight and obese group, presented higher reference MG% levels comparing with the standard levels for healthy women. Copyright © 2014 Elsevier Editora Ltda. All rights reserved.

  15. Comparison of bone density measurement techniques: DXA and Archimedes' principle.

    PubMed

    Keenan, M J; Hegsted, M; Jones, K L; Delany, J P; Kime, J C; Melancon, L E; Tulley, R T; Hong, K D

    1997-11-01

    The standard method for determination of density (g/cm3) of bones from small animals has been the application of Archimedes' principle. A recent development has been software for the determination of "density" (g/cm2) of small animal bones with dual-energy X-ray absorptiometry (DXA). We compared Archimedes' principle and DXA (Hologic QDR-2000) in the measurement of the densities of whole and hollowed femurs of 5- to 6-month-old retired female breeder rats. In an attempt to ensure detectable treatment differences, rats were used from a low-vitamin D Holtzman and a supplemental-vitamin D Sprague-Dawley colony. Whole femur densities were higher for supplemental-vitamin D colony rats than for low vitamin D rats using both techniques (Archimedes' principle, p < 0.002; DXA, p < 0.005), and the densities from the two techniques were highly correlated (r = 0.82, p < 0.0001). Actual density values were higher for Archimedes' principle than for DXA. Other variables such as femur ash weight and calcium content were also highly correlated to densities with both techniques. Hollowed femur density values were higher than whole femur values with Archimedes' principle but lower with DXA. Colony effects for hollowed femur densities were diminished with Archimedes' principle (p < 0.03) and eliminated with DXA (p < 0.53). Investigation of whole bones is more biologically relevant, and both techniques were effective in detecting differences between whole femurs from low-vitamin D and supplemental-vitamin D colony rats.

  16. DXA utilization between 2006 and 2012 in commercially insured younger postmenopausal women

    PubMed Central

    Overman, Robert A.; Farley, Joel F.; Curtis, Jeffrey R.; Zhang, Jie; Gourlay, Margaret L.; Deal, Chad L.

    2015-01-01

    Introduction Reimbursement for dual energy x-ray absorptiometry (DXA) scans in the outpatient setting has declined significantly since 2006. Research through 2011 has suggested reimbursement reductions for DXA scans have corresponded with an overall decreased utilization of DXA. This study updates utilization estimates for DXAs through 2012 in patients with commercial insurance and compares DXA rates before and after reimbursement changes. Methods We evaluated DXA utilization for women age 50–64 from Marketscan Commercial Claims and Encounter database between January 2006 and December 2012 based on CPT codes. We estimated utilization rates per 1,000 person years. We also employed segmented regression analysis of monthly rates to evaluate the change in utilization rates after a proposed reimbursement reduction in July 2009. Results In women aged 50–64; 451,656 DXAs were performed in 2006, a rate of 144 DXAs per 1,000 person years. This rate increased to 149 DXAs per 1,000 person years in 2009 before decreasing to 110 DXAs per 1,000 person years or 667,982 scans in 2012. DXA utilization increased by 2.24 per 1,000 person years until July 2009 then declined by 12.98 DXAs per 1,000 persons, resulting in 37.5 DXAs per person year fewer performed in 2012 compared to 2006. Conclusion Since July 2009 a significant decline in DXA utilization occurred in a younger postmenopausal commercially insured population. This decline corresponds with a time period of reductions in Medicare DXA reimbursement. PMID:25700662

  17. Comparison of femoral strength and fracture risk index derived from DXA-based finite element analysis for stratifying hip fracture risk: A cross-sectional study.

    PubMed

    Yang, Shuman; Luo, Yunhua; Yang, Lang; Dall'Ara, Enrico; Eastell, Richard; Goertzen, Andrew L; McCloskey, Eugene V; Leslie, William D; Lix, Lisa M

    2018-05-01

    Dual-energy X-ray absorptiometry (DXA)-based finite element analysis (FEA) has been studied for assessment of hip fracture risk. Femoral strength (FS) is the maximum force that the femur can sustain before its weakest region reaches the yielding limit. Fracture risk index (FRI), which also considers subject-specific impact force, is defined as the ratio of von Mises stress induced by a sideways fall to the bone yield stress over the proximal femur. We compared risk stratification for prior hip fracture using FS and FRI derived from DXA-based FEA. The study cohort included women aged ≥65years undergoing baseline hip DXA, with femoral neck T-scores <-1 and no osteoporosis treatment; 324 cases had prior hip fracture and 655 controls had no prior fracture. Using anonymized DXA hip scans, we measured FS and FRI. Separate multivariable logistic regression models were used to estimate odds ratios (ORs), c-statistics and their 95% confidence intervals (95% CIs) for the association of hip fracture with FS and FRI. Increased hip fracture risk was associated with lower FS (OR per SD 1.36, 95% CI: 1.15, 1.62) and higher FRI (OR per SD 1.99, 95% CI: 1.63, 2.43) after adjusting for Fracture Risk Assessment Tool (FRAX) hip fracture probability computed with bone mineral density (BMD). The c-statistic for the model containing FS (0.69; 95% CI: 0.65, 0.72) was lower than the c-statistic for the model with FRI (0.77; 95% CI: 0.74, 0.80) or femoral neck BMD (0.74; 95% CI: 0.71, 0.77; all P<0.05). FS and FRI were independently associated with hip fracture, but there were differences in performance characteristics. Copyright © 2018 Elsevier Inc. All rights reserved.

  18. Age-related proximal femur bone mineral loss in South Indian women: a dual energy X-ray absorptiometry study.

    PubMed

    Anburajan, M; Rethinasabapathi, C; Korath, M P; Ponnappa, B G; Kumar, K S; Panicker, T M; Govindan, A; Jagadeesan, G N

    2001-04-01

    i) To collect normative data for proximal femur bone mineral density (BMD) in South Indian women using dual energy X-ray absorptiometry (DXA) and ii) to study the rate and significance of hip bone mineral loss with advancing age in this population. Forty five women, whose age ranged from 16 to 84 years were studied. This sample was drawn randomly from general medical practice at KJ Hospital, Chennai, South India during November, 1997 to April, 1998. Of these 45 cases, 21 were pre-menopausal (mean +/- SD age = 30.9+/-8.8 years) and 24 post-menopausal (mean +/- SD age = 62.1+/-11.0 years). Subjects with secondary bone diseases were excluded. Also excluded were those taking any drugs known to affect calcium metabolism e.g., thiazide diuretics, oestrogen and calcium. Subjects were divided into seven decadal age groups from 15-24 years to 75-84 years. BMD of the right proximal femur was evaluated using a QDR-1000 DXA bone densitometer (Hologic Inc., Waltham, Massachusetts, USA). Data analysis was done with SPSS/PC statistical software package. Linear regression analysis showed significant (p < 0.001) negative correlations between all hip BMD variables at different regions of interest and patient's age. Relative to that at 30 years of age, rates of BMD loss in the neck of femur, trochanter, intertrochanter, total hip and Ward's triangle were 0.68%, 0.65%, 0.58%, 0.61% and 1.05% per annum respectively. Over the age of 65 years, the above mentioned regions BMD decreased by 0.91%, 0.84%, 0.72%, 0.78% and 1.66% per annum respectively. Normative data for proximal femur BMD in South India women have been evaluated and it may prove useful for diagnosing osteoporosis in the women of South India.

  19. Assessment of bone mineral density by DXA and the trabecular microarchitecture of the calcaneum by texture analysis in pre- and postmenopausal women in the evaluation of osteoporosis.

    PubMed

    Karunanithi, R; Ganesan, S; Panicker, T M R; Korath, M Paul; Jagadeesan, K

    2007-10-01

    The in vivo evaluation of trabecular bone structure could be useful in the diagnosis of osteoporosis for the characterization of therapeutic response and understanding the role of parameters other than bone mineral density (BMD) in defining skeletal status. This study was made to evaluate changes taking place in the trabecular architecture of bone with age and menopausal status in women. The findings are compared with the femoral neck bone as well as the trochantar bone mineral density determined by dual energy X-ray absorptiometry (DXA), which is a standard reference test for evaluation of osteoporosis. Seventy females were recruited for the study, 25 premenopausal (mean age ± SD: 39.4 ± 3.8) and 45 postmenopausal (mean age ± SD: 57.9 ± 7.9) women. The right femoral neck bone mineral density was measured for them by dual energy X-ray absorptiometry (DXA). For the same individuals, lateral view radiographs of the right calcaneum were taken as well. The radiographs were digitized and the region of interest (ROI) of 256 × 256 pixels was selected, the run length matrix was computed for calculating seven parameters [Table 1] and the two dimensional fast Fourier transform of the image was calculated. Using the FFT, the power spectral density (PSD) was derived and the root mean square (RMS) value was determined. Our results confirm that age has a significant influence on the texture of the trabecular bone and bone mineral density.

  20. Cost-effectiveness of dual-energy X-ray absorptiometry plus antiresorptive treatment in Australian women with breast cancer who receive aromatase inhibitors.

    PubMed

    Sowa, P Marcin; Downes, Martin J; Gordon, Louisa G

    2017-03-01

    Postmenopausal women with breast cancer on aromatase inhibitor (AI) treatment are at increased risk of bone mineral density loss, which may lead to minimal trauma fractures. We examined the cost-effectiveness of dual energy X-ray absorptiometry (DXA) with antiresorptive (AR) therapy compared with fracture risk assessment, lifestyle advice, and vitamin supplementation. We used a hypothetical Markov cohort model of lifetime duration for 60-year-old women with early stage breast cancer receiving AIs. The data to inform the model came from medical literature, epidemiological reports, and costing data sets. Two eligibility scenarios for AR therapy were considered: (A) osteoporosis and (B) osteopenia or osteoporosis. The main outcomes were incremental cost per quality-adjusted life years gained and cumulative fractures per 1000 women, calculated relative to the comparator. Key aspects of the model were explored in sensitivity analyses. Due to relatively low effectiveness gains, the outcomes were primarily driven by the costs. The incremental cost per quality-adjusted life year gained was A$47,556 and A$253,000 for scenarios A and B, respectively. The numbers of fractures avoided were 56 and 77 per 1000 women, respectively. The results were most sensitive to the initial probability of osteoporosis, baseline risk of fracture, and cohort starting age. Compared with risk assessment and lifestyle advice only, a DXA scan followed by an AR treatment is potentially cost-effective for women aged 60 and over undergoing AI therapy for early breast cancer. However, the number of fractures averted through this intervention is small.

  1. Relationships among diet, physical activity, and dual plane dual-energy X-ray absorptiometry bone outcomes in pre-pubertalgirls.

    PubMed

    Ren, Jie; Brann, Lynn S; Bruening, Kay S; Scerpella, Tamara A; Dowthwaite, Jodi N

    2017-12-01

    In pre-pubertal girls, nutrient intakes and non-aquatic organized activity were evaluated as factors in vertebral body bone mass, structure, and strength. Activity, vitamin B 12 , and dietary fiber predicted bone outcomes most consistently. Exercise and vitamin B 12 appear beneficial, whereas high fiber intake appears to be adverse for vertebral body development. Childhood development sets the baseline for adult fracture risk. Most studies evaluate development using postero-anterior (PA) dual-energy X-ray absorptiometry (DXA) areal bone mineral density, bone mineral content, and bone mineral apparent density. In a prior analysis, we demonstrated that PA DXA reflects posterior element properties, rather than vertebral body fracture sites, such that loading is associated with subtle differences in vertebral body geometry, not 3D density. The current analysis is restricted to pre-pubertal girls, for a focused exploration of key nutrient intakes and physical activity as factors in dual plane indices of vertebral body geometry, density, and strength. This cross-sectional analysis used paired PA and supine lateral (LAT) lumbar spine DXA scans to assess "3D" vertebral body bone mineral apparent density (PALATBMAD), "3D" index of structural strength in axial compression (PALATIBS), and fracture risk index (PALATFRI). Diet data were collected using the Youth/Adolescent Questionnaire (YAQ, 1995); organized physical activity was recorded via calendar-based form. Pearson correlations and backward stepwise multiple linear regression analyzed associations among key nutrients, physical activity, and bone outcomes. After accounting for activity and key covariates, fiber, unsupplemented vitamin B 12 , zinc, carbohydrate, vitamin C, unsupplemented magnesium, and unsupplemented calcium intake explained significant variance for one or more bone outcomes (p < 0.05). After adjustment for influential key nutrients and covariates, activity exposure was associated with postero

  2. Comparison of regional fat measurements by dual-energy X-ray absorptiometry and conventional anthropometry and their association with markers of diabetes and cardiovascular disease risk

    PubMed Central

    Vasan, S K; Osmond, C; Canoy, D; Christodoulides, C; Neville, M J; Di Gravio, C; Fall, C H D; Karpe, F

    2018-01-01

    Background/Objectives: Fat distribution is a strong and independent predictor of type 2 diabetes (T2D) and cardiovascular disease (CVD) and is usually determined using conventional anthropometry in epidemiological studies. Dual-energy X-ray absorptiometry (DXA) can measure total and regional adiposity more accurately. Nonetheless, whether DXA provides more precise estimates of cardiovascular risk in relation to total and regional adiposity is not known. We determined the strength of the associations between DXA- and conventional anthropometry determined fat distribution and T2D and CVD risk markers. Subjects/Methods: Waist (WC) and hip circumference (HC) and DXA was used to measure total and regional adiposity in 4950 (2119 men) participants aged 29–55 years from the Oxford Biobank without pre-existing T2D or CVD. Cross-sectional associations were compared between WC and HC vs. DXA-determined regional adiposity (all z-score normalised) with impaired fasting glucose, hypertriglyceridemia, hypertension and insulin resistance (IR). Results: Following adjustment for total adiposity, upper body adiposity measurements showed consistently increased risk of T2D and CVD risk markers except for abdominal subcutaneous fat in both sexes, and arm fat in men, which showed protective associations. Among upper adiposity depots, visceral fat mass showed stronger odds ratios (OR) ranging from 1.69 to 3.64 compared with WC 1.07–1.83. Among lower adiposity depots, HC showed modest protection for IR in both sexes (men: OR 0.80 (95% confidence interval 0.67, 0.96); women: 0.69 (0.56, 0.86)), whereas gynoid fat and in particular leg fat showed consistent and strong protective effects for all outcomes in both men and women. The differential effect of body fat distribution on CVD and T2D were more pronounced at higher levels of total adiposity. Conclusions: Compared with DXA, conventional anthropometry underestimates the associations of regional adiposity with T2D and CVD risk markers

  3. Low Bone Mineral Content and Challenges in Interpretation of Dual-Energy X-Ray Absorptiometry in Children With Mucopolysaccharidosis Types I, II, and VI

    PubMed Central

    Polgreen, Lynda E.; Thomas, William; Fung, Ellen; Viskochil, David; Stevenson, David A.; Steinberger, Julia; Orchard, Paul; Whitley, Chester B.; Ensrud, Kristine E.

    2013-01-01

    Osteoporosis has been described in animal models of mucopolysaccharidosis (MPS). Whether clinically significant osteoporosis is common among children with MPS is unknown. Therefore, cross-sectional data from whole body (WB; excluding head) and lumbar spine (LS) bone mineral density (BMD) compared with sex-, chronologic age–, and ethnicity-matched healthy individuals (Zage), height-for-age (HAZ) Z-score (ZHAZ) and bone mineral content (BMC) measured by dual-energy X-ray absorptiometry (DXA) in 40 children with MPS were analyzed. A subset of these children (n = 24) was matched 1:3 by age and sex to a group of healthy children (n = 72) for comparison of BMC adjusted for Tanner stage, race, lean body mass, height, and bone area. Low BMD Z-score was defined as Z-score of −2 or less. In children with MPS, 15% had low WB Zage and 48% had low LS Zage; 0% and 6% had low WB ZHAZ and low LS ZHAZ, respectively. Adjusted WB BMC was lower in MPS participants (p = 0.009). In conclusion, children with MPS had deficits in WB BMC after adjustments for stature and bone area. HAZ adjustment underestimated bone deficits (i.e., overestimated WB BMD Z-scores) in children with MPS likely owing to their abnormal bone shape. The influence of severe short stature and bone geometry on DXA measurements must be considered in children with MPS to avoid unnecessary exposure to antiresorptive treatments. PMID:23562131

  4. Challenges of Estimating Fracture Risk with DXA: Changing Concepts About Bone Strength and Bone Density.

    PubMed

    Licata, Angelo A

    2015-07-01

    Bone loss due to weightlessness is a significant concern for astronauts' mission safety and health upon return to Earth. This problem is monitored with bone densitometry (DXA), the clinical tool used to assess skeletal strength. DXA has served clinicians well in assessing fracture risk and has been particularly useful in diagnosing osteoporosis in the elderly postmenopausal population for which it was originally developed. Over the past 1-2 decades, however, paradoxical and contradictory findings have emerged when this technology was widely employed in caring for diverse populations unlike those for which it was developed. Although DXA was originally considered the surrogate marker for bone strength, it is now considered one part of a constellation of factors-described collectively as bone quality-that makes bone strong and resists fracturing, independent of bone density. These characteristics are beyond the capability of routine DXA to identify, and as a result, DXA can be a poor prognosticator of bone health in many clinical scenarios. New clinical tools are emerging to make measurement of bone strength more accurate. This article reviews the historical timeline of bone density measurement (dual X-ray absorptiometry), expands upon the clinical observations that modified the relationship of DXA and bone strength, discusses some of the new clinical tools to predict fracture risk, and highlights the challenges DXA poses in the assessment of fracture risk in astronauts.

  5. Bone mineral density level by dual energy X-ray absorptiometry in rheumatoid arthritis.

    PubMed

    Makhdoom, Asadullah; Rahopoto, Muhammad Qasim; Awan, Shazia; Tahir, Syed Muhammad; Memon, Shazia; Siddiqui, Khaleeque Ahmed

    2017-01-01

    To observe the level of bone mineral density by Dual Energy X-ray Absorptiometry in rheumatoid arthritis patients. The observational study was conducted at Liaquat University of Medical and Health Sciences, Jamshoro, Pakistan, from January 2011 to December 2014. Bone mineral density was measured from the femoral neck, ward's triangle and lumbar spine, in patients 25-55 years of age, who were diagnosed with rheumatoid arthritis. All the cases were assessed for bone mineral density from appendicular as well as axial skeleton. Data was collected through a designed proforma and analysis was performed using SPSS 21. Of the 229 rheumatoid arthritis patients, 33(14.4%) were males. Five (15.1%) males had normal bone density, 14(42.4%) had osteopenia and 14(42.4%) had osteoporosis. Of the 196(85.5%) females, 45(29.9%) had normal bone density, 72 (37.7%) had osteopenia and 79(40.30%) had osteoporosis. Of the 123(53.7%) patients aged 30-50 years, 38(30.9%) had normal bone density, 59(48.0%) had osteopenia, and 26(21.1%) had osteoporosis. Of the 106(46.3%) patients over 50 years, 12(11.3%) had normal bone density, 27 (25.5%) had osteopenia and 67(63.2%) had osteoporosis. Osteoporosis and osteopenia were most common among rheumatoid arthritis patients. Assessment of bone mineral density by Dual Energy X-ray Absorptiometry can lead to quick relief in the clinical symptoms with timely therapy.

  6. Cross-mode bioelectrical impedance analysis in a standing position for estimating fat-free mass validated against dual-energy x-ray absorptiometry.

    PubMed

    Huang, Ai-Chun; Chen, Yu-Yawn; Chuang, Chih-Lin; Chiang, Li-Ming; Lu, Hsueh-Kuan; Lin, Hung-Chi; Chen, Kuen-Tsann; Hsiao, An-Chi; Hsieh, Kuen-Chang

    2015-11-01

    Bioelectrical impedance analysis (BIA) is commonly used to assess body composition. Cross-mode (left hand to right foot, Z(CR)) BIA presumably uses the longest current path in the human body, which may generate better results when estimating fat-free mass (FFM). We compared the cross-mode with the hand-to-foot mode (right hand to right foot, Z(HF)) using dual-energy x-ray absorptiometry (DXA) as the reference. We hypothesized that when comparing anthropometric parameters using stepwise regression analysis, the impedance value from the cross-mode analysis would have better prediction accuracy than that from the hand-to-foot mode analysis. We studied 264 men and 232 women (mean ages, 32.19 ± 14.95 and 34.51 ± 14.96 years, respectively; mean body mass indexes, 24.54 ± 3.74 and 23.44 ± 4.61 kg/m2, respectively). The DXA-measured FFMs in men and women were 58.85 ± 8.15 and 40.48 ± 5.64 kg, respectively. Multiple stepwise linear regression analyses were performed to construct sex-specific FFM equations. The correlations of FFM measured by DXA vs. FFM from hand-to-foot mode and estimated FFM by cross-mode were 0.85 and 0.86 in women, with standard errors of estimate of 2.96 and 2.92 kg, respectively. In men, they were 0.91 and 0.91, with standard errors of the estimates of 3.34 and 3.48 kg, respectively. Bland-Altman plots showed limits of agreement of -6.78 to 6.78 kg for FFM from hand-to-foot mode and -7.06 to 7.06 kg for estimated FFM by cross-mode for men, and -5.91 to 5.91 and -5.84 to 5.84 kg, respectively, for women. Paired t tests showed no significant differences between the 2 modes (P > .05). Hence, cross-mode BIA appears to represent a reasonable and practical application for assessing FFM in Chinese populations. Copyright © 2015 Elsevier Inc. All rights reserved.

  7. Screening for male osteoporosis at an academic medical center: retrospective analysis of DXA usage patterns over 5 years.

    PubMed

    Ivory, Dedri Markita; Siva, Chokkalingam; Velázquez, Celso; Abdinoor, Abdillahi Abdi

    2012-01-01

    Recent findings suggest that men have higher mortality rates than women after a hip fracture. Although the risk of osteoporotic fractures in men is increasing, male osteoporosis still remains underdiagnosed and undertreated. In general, male osteoporosis is given low priority by policy makers in public health initiatives. The purpose of this study is to examine the patterns of use and gender distribution of DXA (dual-energy X-ray absorptiometry) scan usage at a university medical center in the United States. The total number of DXA scans increased during the study period while the percentage of men studied actually declined. The results of this study may lead to heightened awareness among providers who are caring for male patients at risk for osteoporosis.

  8. A Cross-Sectional Study to Assess and Correlate Osteoporosis and Periodontitis among Postmenopausal Women: A Dual Energy X-Ray Absorptiometry Study

    PubMed Central

    Mashalkar, Vaishali Narayan; Suragimath, Girish; Zope, Sameer Anil; Varma, Siddhartha A.

    2018-01-01

    Background: Periodontitis and osteoporosis are two diseases found worldwide and increase in intensity with increasing age of the patients. The severity of osteoporosis and periodontitis are found to be more in women during menopause. The aim of this study was to assess and correlate osteoporosis and periodontal disease among post-menopausal women. Materials and Methods: The study consisted of 94 postmenopausal women in the age range of 45–65 years. All the women underwent dual-energy X-ray absorptiometry (DXA) scan to measure bone mineral density (BMD) and were graded as normal, osteopenic, and osteoporotic based on the T score obtained. Data regarding patient's educational level, socioeconomic status (SES), and body mass index (BMI) was recorded. A detailed periodontal examination was carried out using clinical parameters such as oral hygiene index (OHI), plaque Index (PI), probing pocket depth , and clinical attachment loss to check the level of periodontitis. The level of osteoporosis was correlated with the level of periodontitis. Results: The DXA scan revealed that four women were normal, 44 were osteopenic and 46 were osteoporotic. There was no association found between BMD and OHI, PI, educational status, SES, and BMI. Slight periodontitis was observed in eight women, moderate periodontitis in 62, and severe periodontitis in 24 women. Result suggests that there was a statistical correlation between periodontitis and osteoporosis (P = 0.045). Conclusion: There is a definite correlation found between the severity of periodontitis and osteoporosis among postmenopausal women. A close cooperation between general practitioners and dentists in early diagnosis and treatment of both the diseases will reduce the risk and morbidity among postmenopausal women. PMID:29628721

  9. The Performance of Five Bioelectrical Impedance Analysis Prediction Equations against Dual X-ray Absorptiometry in Estimating Appendicular Skeletal Muscle Mass in an Adult Australian Population

    PubMed Central

    Yu, Solomon C. Y.; Powell, Alice; Khow, Kareeann S. F.; Visvanathan, Renuka

    2016-01-01

    Appendicular skeletal muscle mass (ASM) is a diagnostic criterion for sarcopenia. Bioelectrical impedance analysis (BIA) offers a bedside approach to measure ASM but the performance of BIA prediction equations (PE) varies with ethnicities and body composition. We aim to validate the performance of five PEs in estimating ASM against estimation by dual-energy X-ray absorptiometry (DXA). We recruited 195 healthy adult Australians and ASM was measured using single-frequency BIA. Bland-Altman analysis was used to assess the predictive accuracy of ASM as determined by BIA against DXA. Precision (root mean square error (RMSE)) and bias (mean error (ME)) were calculated according to the method of Sheiner and Beal. Four PEs (except that by Kim) showed ASM values that correlated strongly with ASMDXA (r ranging from 0.96 to 0.97, p < 0.001). The Sergi equation performed the best with the lowest ME of −1.09 kg (CI: −0.84–−1.34, p < 0.001) and the RMSE was 2.09 kg (CI: 1.72–2.47). In men, the Kyle equation performed better with the lowest ME (−0.32 kg (CI: −0.66–0.02) and RMSE (1.54 kg (CI: 1.14–1.93)). The Sergi equation is applicable in adult Australians (Caucasian) whereas the Kyle equation can be considered in males. The need remains to validate PEs in other ethnicities and to develop equations suitable for multi-frequency BIA. PMID:27043617

  10. Assessing Body Composition of Children and Adolescents Using Dual-Energy X-Ray Absorptiometry, Skinfolds, and Electrical Impedance

    ERIC Educational Resources Information Center

    Mooney, Angela; Kelsey, Laurel; Fellingham, Gilbert W.; George, James D.; Hager, Ron L.; Myrer, J. William; Vehrs, Pat R.

    2011-01-01

    To determine the validity and reliability of percent body fat estimates in 177 boys and 154 girls between 12-17 years of age, percent body fat was assessed once using dual-energy X-ray absorptiometry and twice using the sum of two skinfolds and three bioelectrical impedance analysis devices. The assessments were repeated on 79 participants on a…

  11. Associations Between Sedentary Time, Physical Activity, and Dual-Energy X-ray Absorptiometry Measures of Total Body, Android, and Gynoid Fat Mass in Children.

    PubMed

    McCormack, Lacey; Meendering, Jessica; Specker, Bonny; Binkley, Teresa

    2016-01-01

    Negative health outcomes are associated with excess body fat, low levels of physical activity (PA), and high sedentary time (ST). Relationships between PA, ST, and body fat distribution, including android and gynoid fat, assessed using dual-energy X-ray absorptiometry (DXA) have not been measured in children. The purpose of this study was to test associations between levels of activity and body composition in children and to evaluate if levels of activity predict body composition by DXA and by body mass index percentile in a similar manner. PA, ST, and body composition from 87 children (8.8-11.8 yr, grades 3-5, 44 boys) were used to test the association among study variables. Accelerometers measured PA and ST. Body composition measured by DXA included bone mineral content (BMC) and fat and lean mass of the total body (TB, less head), android, and gynoid regions. ST (range: 409-685 min/wk) was positively associated with TB percent fat (0.03, 95% confidence interval [CI]: 0.00-0.05) and android fat mass (1.5 g, 95% CI: 0.4-3.0), and inversely associated with the lean mass of the TB (-10.7 g, 95% CI: -20.8 to -0.63) and gynoid regions (-2.2 g, 95% CI: -4.3 to -0.2), and with BMC (-0.43 g, 95% CI: 0.77-0.09). Moderate-to-vigorous PA was associated with lower TB (-53 g, 95% CI: -87 to -18), android (-5 g, 95% CI: -8 to -2]), and gynoid fat (-6 g, 95% CI: -11 to -0.5). Vigorous activity results were similar. Light PA was associated with increased TB (17.1 g, 95% CI: 3.0-31.3) and gynoid lean mass (3.9 g, 95% CI: 1.0-6.8) and BMC (0.59 g, 95% CI: 0.10-1.07). In boys, there were significant associations between activity and DXA percent body fat measures that were not found with the body mass index percentile. Objective measures of PA were inversely associated with TB, android, and gynoid fat, whereas ST was directly associated with TB percent fat and, in particular, android fat. Activity levels predict body composition measures by DXA and, in

  12. High resolution magnetic resonance imaging of the calcaneus: age-related changes in trabecular structure and comparison with dual X-ray absorptiometry measurements

    NASA Technical Reports Server (NTRS)

    Ouyang, X.; Selby, K.; Lang, P.; Engelke, K.; Klifa, C.; Fan, B.; Zucconi, F.; Hottya, G.; Chen, M.; Majumdar, S.; hide

    1997-01-01

    A high-resolution magnetic resonance imaging (MRI) protocol, together with specialized image processing techniques, was applied to the quantitative measurement of age-related changes in calcaneal trabecular structure. The reproducibility of the technique was assessed and the annual rates of change for several trabecular structure parameters were measured. The MR-derived trabecular parameters were compared with calcaneal bone mineral density (BMD), measured by dual X-ray absorptiometry (DXA) in the same subjects. Sagittal MR images were acquired at 1.5 T in 23 healthy women (mean age: 49.3 +/- 16.6 [SD]), using a three-dimensional gradient echo sequence. Image analysis procedures included internal gray-scale calibration, bone and marrow segmentation, and run-length methods. Three trabecular structure parameters, apparent bone volume (ABV/TV), intercept thickness (I.Th), and intercept separation (I.Sp) were calculated from the MR images. The short- and long-term precision errors (mean %CV) of these measured parameters were in the ranges 1-2% and 3-6%, respectively. Linear regression of the trabecular structure parameters vs. age showed significant correlation: ABV/TV (r2 = 33.7%, P < 0.0037), I.Th (r2 = 26.6%, P < 0.0118), I.Sp (r2 = 28.9%, P < 0.0081). These trends with age were also expressed as annual rates of change: ABV/TV (-0.52%/year), I.Th (-0.33%/year), and I.Sp (0.59%/year). Linear regression analysis also showed significant correlation between the MR-derived trabecular structure parameters and calcaneal BMD values. Although a larger group of subjects is needed to better define the age-related changes in trabecular structure parameters and their relation to BMD, these preliminary results demonstrate that high-resolution MRI may potentially be useful for the quantitative assessment of trabecular structure.

  13. Reference Values of Total Lean Mass, Appendicular Lean Mass, and Fat Mass Measured with Dual-Energy X-ray Absorptiometry in a Healthy Mexican Population.

    PubMed

    Clark, Patricia; Denova-Gutiérrez, Edgar; Ambrosi, Regina; Szulc, Pawel; Rivas-Ruiz, Rodolfo; Salmerón, Jorge

    2016-11-01

    The aim of this study was to develop age- and gender-specific reference values of total lean body mass (LBM), appendicular lean body mass (ALBM), and fat mass (FM) by dual-energy X-ray absorptiometry (DXA) data in a healthy Mexican population. A cross-sectional analysis was conducted on 9518 healthy subjects 7-89 years of age participating in the baseline measurement of the Health Workers Cohort Study. Using DXA, LBM, ALBM, and FM were measured. Using these data, LBM index (LBMI), ALBM index (ALBMI), and fat mass index (FMI) were calculated. LMI, ALMI, and FMI were calculated as the LBM, ALBM, and FM kg divided by the height in meters squared. Males and females were analyzed separately; sex-specific means and standard deviations for LBM, ALBM, FM, LBMI, ALBMI, and FMI were calculated. A total of 2829 males and 6694 females were included in the final analysis. Strong sex gaps were observed after 12 years in LBM, ALBM, LBMI, and ALBMI (P < 0.01). LBM and ALBM values continue to increase for males up to age 20; females plateaued approximately after age 15. Significant sex differences were also observed for FM and FMI. Significant sex- and age-related differences exist in LBM, ALBM, and FM in the Mexican population. In addition, given the null data available in this area, these reference values may be useful in the evaluation of a variety of childhood and adult abnormalities involving lean body mass deficits, mainly in the assessment of muscle wasting, with important medical and epidemiological uses.

  14. Bone mineral density test

    MedlinePlus

    ... density test; Bone densitometry; DEXA scan; DXA; Dual-energy x-ray absorptiometry; p-DEXA; Osteoporosis - BMD ... most common and accurate way uses a dual-energy x-ray absorptiometry (DEXA) scan. DEXA uses low- ...

  15. The utility of dual-energy X-ray absorptiometry, calcaneal quantitative ultrasound, and fracture risk indices (FRAX® and Osteoporosis Risk Assessment Instrument) for the identification of women with distal forearm or hip fractures: A pilot study.

    PubMed

    Esmaeilzadeh, Sina; Cesme, Fatih; Oral, Aydan; Yaliman, Ayse; Sindel, Dilsad

    2016-08-01

    Dual-energy X-ray absorptiometry (DXA) is considered the "gold standard" in predicting osteoporotic fractures. Calcaneal quantitative ultrasound (QUS) variables are also known to predict fractures. Fracture risk assessment tools may also guide us for the detection of individuals at high risk for fractures. The aim of this case-control study was to evaluate the utility of DXA bone mineral density (BMD), calcaneal QUS parameters, FRAX® (Fracture Risk Assessment Tool), and Osteoporosis Risk Assessment Instrument (ORAI) for the discrimination of women with distal forearm or hip fractures. This case-control study included 20 women with a distal forearm fracture and 18 women with a hip fracture as cases and 76 age-matched women served as controls. BMD at the spine, proximal femur, and radius was measured using DXA and acoustic parameters of bone were obtained using a calcaneal QUS device. FRAX® 10-year probability of fracture and ORAI scores were also calculated in all participants. Receiver operating characteristic (ROC) analysis was used to assess fracture discriminatory power of all the tools. While all DXA BMD, and QUS variables and FRAX® fracture probabilities demonstrated significant areas under the ROC curves for the discrimination of hip-fractured women and those without, only 33% radius BMD, broadband ultrasound attenuation (BUA), and FRAX® major osteoporotic fracture probability calculated without BMD showed significant discriminatory power for distal forearm fractures. It can be concluded that QUS variables, particularly BUA, and FRAX® major osteoporotic fracture probability without BMD are good candidates for the identification of both hip and distal forearm fractures.

  16. Modeling the shape and composition of the human body using dual energy X-ray absorptiometry images

    PubMed Central

    Shepherd, John A.; Fan, Bo; Schwartz, Ann V.; Cawthon, Peggy; Cummings, Steven R.; Kritchevsky, Stephen; Nevitt, Michael; Santanasto, Adam; Cootes, Timothy F.

    2017-01-01

    There is growing evidence that body shape and regional body composition are strong indicators of metabolic health. The purpose of this study was to develop statistical models that accurately describe holistic body shape, thickness, and leanness. We hypothesized that there are unique body shape features that are predictive of mortality beyond standard clinical measures. We developed algorithms to process whole-body dual-energy X-ray absorptiometry (DXA) scans into body thickness and leanness images. We performed statistical appearance modeling (SAM) and principal component analysis (PCA) to efficiently encode the variance of body shape, leanness, and thickness across sample of 400 older Americans from the Health ABC study. The sample included 200 cases and 200 controls based on 6-year mortality status, matched on sex, race and BMI. The final model contained 52 points outlining the torso, upper arms, thighs, and bony landmarks. Correlation analyses were performed on the PCA parameters to identify body shape features that vary across groups and with metabolic risk. Stepwise logistic regression was performed to identify sex and race, and predict mortality risk as a function of body shape parameters. These parameters are novel body composition features that uniquely identify body phenotypes of different groups and predict mortality risk. Three parameters from a SAM of body leanness and thickness accurately identified sex (training AUC = 0.99) and six accurately identified race (training AUC = 0.91) in the sample dataset. Three parameters from a SAM of only body thickness predicted mortality (training AUC = 0.66, validation AUC = 0.62). Further study is warranted to identify specific shape/composition features that predict other health outcomes. PMID:28423041

  17. Agreement of BMI-Based Equations and DXA in Determining Body-Fat Percentage in Adults With Down Syndrome.

    PubMed

    Esco, Michael R; Nickerson, Brett S; Bicard, Sara C; Russell, Angela R; Bishop, Phillip A

    2016-01-01

    The purpose of this investigation was to evaluate measurements of body-fat percentage (BF%) in 4 body-mass-index- (BMI) -based equations and dual-energy X-ray absorptiometry (DXA) in individuals with Down syndrome (DS). Ten male and 10 female adults with DS volunteered for this study. Four regression equations for estimating BF% based on BMI previously developed by Deurenberg et al. (DE(BMI-BF%)), Gallagher et al. (GA(BMI-BF%)), Womersley & Durnin (WO(BMI-BF%)), and Jackson et al. (JA(BMI-BF%)) were compared with DXA. There was no significant difference (p = .659) in mean BF% values between JA(BMI-BF%) (BF% = 40.80% ± 6.3%) and DXA (39.90% ± 11.1%), while DE(BMI-BF%) (34.40% ± 9.0%), WO(BMI-BF%) (35.10% ± 9.4%), and GA(BMI-BF%) (35.10% ± 9.4%) were significantly (p < .001) lower. The limits of agreement (1.96 SD of the constant error) varied from 9.80% to 16.20%. Therefore, BMI-based BF% equations should not be used in individuals with DS.

  18. A Phase II Trial on the Effect of Low-Dose versus High-Dose Vitamin D Supplementation on Bone Mass in Adults with Neurofibromatosis 1 (NF1)

    DTIC Science & Technology

    2017-10-01

    Cincinnati enrollment center CGRP = Clinical Genetics Research Program DEXA = dual energy x-ray absorptiometry Ddrops = formulation of...cholecalciferol (vitamin D3) DXA = dual energy x-ray absorptiometry FDA= Federal Drug Administration HAM = University of Hamburg enrollment center IRB

  19. Adiposity assessments: agreement between dual-energy X-ray absorptiometry and anthropometric measures in US children12-3

    PubMed Central

    Tuan, Nguyen T; Wang, Youfa

    2014-01-01

    Objectives To evaluate performance of anthropometric measures relative to percentage body fat (%BF) measured by dual-energy X-ray absorptiometry (DXA) in children. Design and Methods We used data from 8-19-y-old US children enrolled in a nationally representative cross-sectional survey in 2001-2004 (n=5,355) with measured %BF, body mass index (BMI), waist circumference (WC), waist-to-height ratio (WHtR) and triceps skinfold thickness (TSF). Agreement and prediction were evaluated based on standardized regression coefficients (β), kappa, and the area under the receiver-operating characteristic curves (AUC). Results The association between Z scores for %BF and anthropometric measures was strong (β of ~0.75-0.90, kappa of ~0.60-0.75, and AUC of ~0.87-0.98; P<0.001 for all), with only some variations by race-ethnicity, mostly in girls. In boys, TSF and WHtR Z-scores had stronger agreement with %BF than BMI (β of 0.91 and 0.86 vs. 0.79, kappa of 0.75 and 0.71 vs. 0.59, and AUC of 0.97 and 0.97 vs. 0.91; P<0.05 for all). In boys with BMI < median but %BF ≥ median, β value of TSF Z score was higher than those from BMI. In girls, TSF also provided a higher agreement than BMI, but was only statistically higher for kappa. Conclusions High agreement and small racial-ethnic variations in the association between percentage body fat and anthropometric measures support the use of anthropometric measures, especially waist-to-height ratio and triceps skinfold thickness, as proxy indicators for adiposity. PMID:24415710

  20. DXA and pQCT predict pertrochanteric and not femoral neck fracture load in a human side-impact fracture model.

    PubMed

    Gebauer, Matthias; Stark, Olaf; Vettorazzi, Eik; Grifka, Joachim; Püschel, Klaus; Amling, Michael; Beckmann, Johannes

    2014-01-01

    The validity of dual energy X-ray absorptiometry (DXA) and peripheral quantitative computed tomography (pQCT) measurements as predictors of pertrochanteric and femoral neck fracture loads was compared in an experimental simulation of a fall on the greater trochanter. 65 proximal femora were harvested from patients at autopsy. All specimens were scanned with use of DXA for areal bone mineral density and pQCT for volumetric densities at selected sites of the proximal femur. A three-point bending test simulating a side-impact was performed to determine fracture load and resulted in 16 femoral neck and 49 pertrochanteric fractures. Regression analysis revealed that DXA BMD trochanter was the best variable at predicting fracture load of pertrochanteric fractures with an adjusted R(2) of 0.824 (p < 0.0001). There was no correlation between densitometric parameters and the fracture load of femoral neck fractures. A significant correlation further was found between body weight, height, femoral head diameter, and neck length on the one side and fracture load on the other side, irrespective of the fracture type. Clinically, the DXA BMD trochanter should be favored and integrated routinely as well as biometric and geometric parameters, particularly in elderly people with known osteoporosis at risk for falls. © 2013 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  1. Effect of endodontic cement on bone mineral density using serial dual-energy x-ray absorptiometry.

    PubMed

    Saghiri, Mohammad Ali; Orangi, Jafar; Tanideh, Nader; Janghorban, Kamal; Sheibani, Nader

    2014-05-01

    Materials with new compositions were tested in order to develop dental materials with better properties. Calcium silicate-based cements, including white mineral trioxide aggregate (WMTA), may improve osteopromotion because of their composition. Nano-modified cements may help researchers produce ideal root-end filling materials. Serial dual-energy x-ray absorptiometry measurement was used to evaluate the effects of particle size and the addition of tricalcium aluminate (C3A) to a type of mineral trioxide aggregate-based cement on bone mineral density and the surrounding tissues in the mandible of rabbits. Forty mature male rabbits (N = 40) were anesthetized, and a bone defect measuring 7 × 1 × 1 mm was created on the semimandible. The rabbits were divided into 2 groups, which were subdivided into 5 subgroups with 4 animals each based on the defect filled by the following: Nano-WMTA (patent application #13/211.880), WMTA (as standard), WMTA without C3A, Nano-WMTA + 2% Nano-C3A (Fujindonjnan Industrial Co, Ltd, Fujindonjnan Xiamen, China), and a control group. Twenty and forty days postoperatively, the animals were sacrificed, and the semimandibles were removed for DXA measurement. The Kruskal-Wallis test followed by the Mann-Whitney U test showed significant differences between the groups at a significance level of P < .05. P values calculated by the Kruskal-Wallis test were .002 for bone mineral density at both intervals and P20 day = .004 and P40 day = .005 for bone mineral content. This study showed that bone regeneration was enhanced by reducing the particle size (nano-modified) and C3A mixture. This may relate to the existence of an external supply of minerals and a larger surface area of nano-modified material, which may lead to faster release rate of Ca(2+), inducing bone formation. Adding Nano-C3A to Nano-WMTA may improve bone regeneration properties. Copyright © 2014 American Association of Endodontists. All rights reserved.

  2. Height adjustment in assessing dual energy x-ray absorptiometry measurements of bone mass and density in children.

    PubMed

    Zemel, Babette S; Leonard, Mary B; Kelly, Andrea; Lappe, Joan M; Gilsanz, Vicente; Oberfield, Sharon; Mahboubi, Soroosh; Shepherd, John A; Hangartner, Thomas N; Frederick, Margaret M; Winer, Karen K; Kalkwarf, Heidi J

    2010-03-01

    In children, bone mineral content (BMC) and bone mineral density (BMD) measurements by dual-energy x-ray absorptiometry (DXA) are affected by height status. No consensus exists on how to adjust BMC or BMD (BMC/BMD) measurements for short or tall stature. The aim of this study was to compare various methods to adjust BMC/BMD for height in healthy children. Data from the Bone Mineral Density in Childhood Study (BMDCS) were used to develop adjustment methods that were validated using an independent cross-sectional sample of healthy children from the Reference Data Project (RDP). We conducted the study in five clinical centers in the United States. We included 1546 BMDCS and 650 RDP participants (7 to 17 yr of age, 50% female). No interventions were used. We measured spine and whole body (WB) BMC and BMD Z-scores for age (BMC/BMD(age)), height age (BMC/BMD(height age)), height (BMC(height)), bone mineral apparent density (BMAD(age)), and height-for-age Z-score (HAZ) (BMC/BMD(haz)). Spine and WB BMC/BMD(age)Z and BMAD(age)Z were positively (P < 0.005; r = 0.11 to 0.64) associated with HAZ. Spine BMD(haz) and BMC(haz)Z were not associated with HAZ; WB BMC(haz)Z was modestly associated with HAZ (r = 0.14; P = 0.0003). All other adjustment methods were negatively associated with HAZ (P < 0.005; r = -0.20 to -0.34). The deviation between adjusted and BMC/BMD(age) Z-scores was associated with age for most measures (P < 0.005) except for BMC/BMD(haz). Most methods to adjust BMC/BMD Z-scores for height were biased by age and/or HAZ. Adjustments using HAZ were least biased relative to HAZ and age and can be used to evaluate the effect of short or tall stature on BMC/BMD Z-scores.

  3. Relationship between Weight, Body Mass Index, and Bone Mineral Density in Men Referred for Dual-Energy X-Ray Absorptiometry Scan in Isfahan, Iran.

    PubMed

    Salamat, Mohammad Reza; Salamat, Amir Hossein; Abedi, Iraj; Janghorbani, Mohsen

    2013-01-01

    Objective. Although several studies have investigated the association between body mass index (BMI) and bone mineral density (BMD), the results are inconsistent. The aim of this study was to further investigate the relation between BMI, weight and BMD in an Iranian men population. Methods. A total of 230 men 50-79 years old were examined. All men underwent a standard BMD scans of hip (total hip, femoral neck, trochanter, and femoral shaft) and lumbar vertebrae (L2-L4) using a Dual-Energy X-ray Absorptiometry (DXA) scan and examination of body size. Participants were categorised in two BMI group: normal weight <25.0 kg/m(2) and overweight and obese, BMI ≥ 25 kg/m(2). Results. Compared to men with BMI ≥ 25, the age-adjusted odds ratio of osteopenia was 2.2 (95% CI 0.85, 5.93) and for osteoporosis was 4.4 (1.51, 12.87) for men with BMI < 25. It was noted that BMI and weight was associated with a high BMD, compatible with a diagnosis of osteoporosis. Conclusions. These data indicate that both BMI and weight are associated with BMD of hip and vertebrae and overweight and obesity decreased the risk for osteoporosis. The results of this study highlight the need for osteoporosis prevention strategies in elderly men as well as postmenopausal women.

  4. Creatine ( methyl-d3) dilution in urine for estimation of total body skeletal muscle mass: accuracy and variability vs. MRI and DXA.

    PubMed

    Clark, Richard V; Walker, Ann C; Miller, Ram R; O'Connor-Semmes, Robin L; Ravussin, Eric; Cefalu, William T

    2018-01-01

    A noninvasive method to estimate muscle mass based on creatine ( methyl-d 3 ) (D 3 -creatine) dilution using fasting morning urine was evaluated for accuracy and variability over a 3- to 4-mo period. Healthy older (67- to 80-yr-old) subjects ( n = 14) with muscle wasting secondary to aging and four patients with chronic disease (58-76 yr old) fasted overnight and then received an oral 30-mg dose of D 3 -creatine at 8 AM ( day 1). Urine was collected during 4 h of continued fasting and then at consecutive 4- to 8-h intervals through day 5. Assessment was repeated 3-4 mo later in 13 healthy subjects and 1 patient with congestive heart failure. Deuterated and unlabeled creatine and creatinine were measured using liquid chromatography-tandem mass spectrometry. Total body creatine pool size and muscle mass were calculated from D 3 -creatinine enrichment in urine. Muscle mass was also measured by whole body MRI and 24-h urine creatinine, and lean body mass (LBM) was measured by dual-energy X-ray absorptiometry (DXA). D 3 -creatinine urinary enrichment from day 5 provided muscle mass estimates that correlated with MRI for all subjects ( r = 0.88, P < 0.0001), with less bias [difference from MRI = -3.00 ± 2.75 (SD) kg] than total LBM assessment by DXA, which overestimated muscle mass vs. MRI (+22.5 ± 3.7 kg). However, intraindividual variability was high with the D 3 -creatine dilution method, with intrasubject SD for estimated muscle mass of 2.5 kg vs. MRI (0.5 kg) and DXA (0.8 kg). This study supports further clinical validation of the D 3 -creatine method for estimating muscle mass. NEW & NOTEWORTHY Measurement of creatine ( methyl-d 3 ) (D 3 -creatine) and D 3 -creatinine excretion in fasted morning urine samples may be a simple, less costly alternative to MRI or dual-energy X-ray absorptiometry (DXA) to calculate total body muscle mass. The D 3 -creatine enrichment method provides estimates of muscle mass that correlate well with MRI, and with less

  5. A multinational study to develop universal standardization of whole-body bone density and composition using GE Healthcare Lunar and Hologic DXA systems.

    PubMed

    Shepherd, John A; Fan, Bo; Lu, Ying; Wu, Xiao P; Wacker, Wynn K; Ergun, David L; Levine, Michael A

    2012-10-01

    Dual-energy x-ray absorptiometry (DXA) is used to assess bone mineral density (BMD) and body composition, but measurements vary among instruments from different manufacturers. We sought to develop cross-calibration equations for whole-body bone density and composition derived using GE Healthcare Lunar and Hologic DXA systems. This multinational study recruited 199 adult and pediatric participants from a site in the US (n = 40, ages 6 through 16 years) and one in China (n = 159, ages 5 through 81 years). The mean age of the participants was 44.2 years. Each participant was scanned on both GE Healthcare Lunar and Hologic Discovery or Delphi DXA systems on the same day (US) or within 1 week (China) and all scans were centrally analyzed by a single technologist using GE Healthcare Lunar Encore version 14.0 and Hologic Apex version 3.0. Paired t-tests were used to test the results differences between the systems. Multiple regression and Deming regressions were used to derive the cross-conversion equations between the GE Healthcare Lunar and Hologic whole-body scans. Bone and soft tissue measures were highly correlated between the GE Healthcare Lunar and Hologic and systems, with r ranging from 0.96 percent fat [PFAT] to 0.98 (BMC). Significant differences were found between the two systems, with average absolute differences for PFAT, BMC, and BMD of 1.4%, 176.8 g and 0.013 g/cm(2) , respectively. After cross-calibration, no significant differences remained between GE Healthcare Lunar measured results and the results converted from Hologic. The equations we derived reduce differences between BMD and body composition as determined by GE Healthcare Lunar and Hologic systems and will facilitate combining study results in clinical or epidemiological studies. Copyright © 2012 American Society for Bone and Mineral Research.

  6. Investigating the level of agreement of two positioning protocols when using dual energy X-ray absorptiometry in the assessment of body composition.

    PubMed

    Shiel, Flinn; Persson, Carl; Simas, Vini; Furness, James; Climstein, Mike; Schram, Ben

    2017-01-01

    Dual energy X-ray absorptiometry (DXA) is a commonly used instrument for analysing segmental body composition (BC). The information from the scan guides the clinician in the treatment of conditions such as obesity and can be used to monitor recovery of lean mass following injury. Two commonly used DXA positioning protocols have been identified-the Nana positioning protocol and the National Health and Nutrition Examination Survey (NHANES). Both protocols have been shown to be reliable. However, only one study has assessed the level of agreement between the protocols and ascertained the participants' preference of protocol based upon comfort. Given the paucity of research in the field and the growing use of DXA in both healthy and pathological populations further research determining the most appropriate positioning protocol is warranted. Therefore, the aims of this study were to assess the level of agreement between results from the NHANES protocol and Nana protocol, and the participants' preference of protocol based on comfort. Thirty healthy participants (15 males, 15 females, aged 23-59 years) volunteered to participate in this study. These participants underwent two whole body DXA scans in a single morning (Nana positioning protocol and NHANES positioning protocol), in a randomised order. Each participant attended for scanning wearing minimal clothing and having fasted overnight, refrained from exercise in the past 24 h and voided their bladders. Level of agreement, comparing NAHNES to Nana protocol was assessed using an intra-class correlation coefficient (ICC), concordance correlation coefficient (CCC) and percentage change in mean. Limit of agreement comparing the two protocols were assessed using plots, mean difference and confidence limits. Participants were asked to indicate the protocol they found most comfortable. When assessing level of agreement between protocols both the ICC and CCC scores were very high and ranged from 0.987 to 0.997 for whole body

  7. Osteoporosis Care in the United States After Declines in Reimbursements for DXA

    PubMed Central

    Hayes, Burton L.; Curtis, Jeffrey R.; Laster, Andrew; Saag, Kenneth; Tanner, S. Bobo; Liu, Caiqin; Womack, Catherine; Johnson, Karen C.; Khaliq, Fazila; Carbone, Laura D.

    2015-01-01

    In January 2007, in the United States (US), Medicare initiated a series of cuts to reimbursement for dual-energy X-ray absorptiometry (DXA) services performed in the nonfacility setting that by January 2010 reduced payments for these services by more than 60% compared with 2006 levels. The objectives of this study were to determine if a temporal association exists between Medicare Physician Fee Schedule changes in office-based DXA reimbursement and attendance at educational conferences for osteoporosis, physicians’ perceptions of changes in their medical practices, or national trends in retail prescription medications for osteoporosis in those aged 65 and older. Compared with the 2 yr before the decline in Medicare reimbursement for DXA (2005–2006), attendance at educational meetings for osteoporosis in the US declined in the 2 yr after these cuts (2007–2008) by 6%; declines in attendance were only present in meetings selective for bone densitometry. Survey participants reported changes in DXA services with approximately one-third indicating that they had either decreased the number of DXAs they performed or declined service contracts or hardware/software updates compared with 2005–2006. The number of retail prescriptions for Food and Drug Administratione–approved osteoporosis drugs (excluding estrogen compounds and raloxifene) in the age 65 and older population increased by 5.5% in the time period 2007–2008 compared with 2005–2006. However, in the last year of the study (2008), total retail prescriptions for these drugs experienced for the first time over the interval of the study, a decline (1.4%) compared with the previous year. This occurred despite a 2.6% increase in the US population age 65 and older. In conclusion, there were temporal associations noted between Medicare cuts in DXA payments in attendance at educational conferences for bone densitometry, self-report of office-based provision of DXA services in the US, and retail prescriptions

  8. Vertebral Fracture Assessment by dual-energy X-ray absorptiometry: insurance coverage issues in the United States. A White Paper of the International Society for Clinical Densitometry.

    PubMed

    Laster, Andrew J; Lewiecki, E Michael

    2007-01-01

    Clinical trial data and fracture risk prediction models unequivocally demonstrate the utility of identifying prevalent vertebral fractures to predict future fractures of all types. Knowledge of prevalent vertebral fractures can alter patient management decisions and result in initiation of therapy to reduce fracture risk in some patients who would not otherwise be treated. Cost-benefit analysis demonstrates that identifying and treating patients with vertebral fractures, even those with a densitometric classification of osteopenia, is cost effective. Vertebral fractures can be readily identified in the office setting using standard radiography or Vertebral Fracture Assessment (VFA), a software addition to a central dual-energy X-ray absorptiometry (DXA) machine. In the United States, VFA was assigned a Current Procedural Terminology (CPT) code in January 2005. Nevertheless, coverage of VFA has not been uniformly embraced by Medicare carriers, companies that contract with the federal government to administer Medicare coverage and process claims for a region of the United States. Unlike DXA, for which uniform national coverage of qualified Medicare beneficiaries is mandated by the Balanced Budget Act of 1997, VFA coverage policies are determined by the local Medicare carriers. Third-party insurers are also variable in their coverage of VFA. This International Society for Clinical Densitometry (ISCD) White Paper documents the role of VFA in the evaluation and treatment of women with postmenopausal osteoporosis and compares it with standard spine radiography. Arguments used by some Medicare carriers and insurers to deny coverage of VFA in the United States are analyzed and critiqued. For health care providers within the United States, this White Paper may serve as a resource to respond to insurers who deny coverage of VFA. For health care providers regardless of their country, this article underscores the value of VFA as an alternative to spine radiography in the

  9. DXA in the assessment of subchondral bone mineral density in knee osteoarthritis--A semi-standardized protocol after systematic review.

    PubMed

    Sepriano, Alexandre; Roman-Blas, Jorge A; Little, Robert D; Pimentel-Santos, Fernando; Arribas, Jose María; Largo, Raquel; Branco, Jaime C; Herrero-Beaumont, Gabriel

    2015-12-01

    Subchondral bone mineral density (sBMD) contributes to the initiation and progression of knee osteoarthritis (OA). Reliable methods to assess sBMD status may predict the response of specific OA phenotypes to targeted therapies. While dual-energy X-ray absorptiometry (DXA) of the knee can determine sBMD, no consensus exists regarding its methodology. Construct a semi-standardized protocol for knee DXA to measure sBMD in patients with OA of the knee by evaluating the varying methodologies present in existing literature. We performed a systematic review of original papers published in PubMed and Web of Science from their inception to July 2014 using the following search terms: subchondral bone, osteoarthritis, and bone mineral density. DXA of the knee can be performed with similar reproducibility values to those proposed by the International Society for Clinical Densitometry for the hip and spine. We identified acquisition view, hip rotation, knee positioning and stabilization, ROI location and definition, and the type of analysis software as important sources of variation. A proposed knee DXA protocol was constructed taking into consideration the results of the review. DXA of the knee can be reliably performed in patients with knee OA. Nevertheless, we found substantial methodological variation across previous studies. Methodological standardization may provide a foundation from which to establish DXA of the knee as a valid tool for identification of SB changes and as an outcome measure in clinical trials of disease modifying osteoarthritic drugs. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Body mass index bias in defining obesity of diverse young adults: The Training Intervention and Genetics of Exercise Response (TIGER) Study

    USDA-ARS?s Scientific Manuscript database

    The BMI cut-score used to define overweight and obesity was derived primarily using data from Caucasian men and women. The present study evaluated the racial/ethnic bias of BMI to estimate the adiposity of young men and women (aged 17–35 years) using dual-energy X-ray absorptiometry (DXA) determinat...

  11. The relationship between DXA-based and anthropometric measures of visceral fat and morbidity in women

    PubMed Central

    2013-01-01

    Background Excess accumulation of visceral fat is a prominent risk factor for cardiovascular and metabolic morbidity. While computed tomography (CT) is the gold standard to measure visceral adiposity, this is often not possible for large studies - thus valid, but less expensive and intrusive proxy measures of visceral fat are required such as dual-energy X-ray absorptiometry (DXA). Study aims were to a) identify a valid DXA-based measure of visceral adipose tissue (VAT), b) estimate VAT heritability and c) assess visceral fat association with morbidity in relation to body fat distribution. Methods A validation sample of 54 females measured for detailed body fat composition - assessed using CT, DXA and anthropometry – was used to evaluate previously published predictive models of CT-measured visceral fat. Based upon a validated model, we realised an out-of-sample estimate of abdominal VAT area for a study sample of 3457 female volunteer twins and estimated VAT area heritability using a classical twin study design. Regression and residuals analyses were used to assess the relationship between adiposity and morbidity. Results Published models applied to the validation sample explained >80% of the variance in CT-measured visceral fat. While CT visceral fat was best estimated using a linear regression for waist circumference, CT body cavity area and total abdominal fat (R2 = 0.91), anthropometric measures alone predicted VAT almost equally well (CT body cavity area and waist circumference, R2 = 0.86). Narrow sense VAT area heritability for the study sample was estimated to be 58% (95% CI: 51-66%) with a shared familial component of 24% (17-30%). VAT area is strongly associated with type 2 diabetes (T2D), hypertension (HT), subclinical atherosclerosis and liver function tests. In particular, VAT area is associated with T2D, HT and liver function (alanine transaminase) independent of DXA total abdominal fat and body mass index (BMI). Conclusions DXA and

  12. The Ability of Lumbar Spine DXA and Phalanx QUS to Detect Previous Fractures in Young Thalassemic Patients With Hypogonadism, Hypothyroidism, Diabetes, and Hepatitis-B: A 2-Year Subgroup Analysis From the Taranto Area of Apulia Region

    PubMed Central

    Neglia, Cosimo; Peluso, Angelo; di Rosa, Salvatore; Ferrarese, Antonio; Di Tanna, Gianluca; Caiaffa, Vincenzo; Benvenuto, Marco; Cozma, Alexandru; Chitano, Giovanna; Agnello, Nadia; Paladini, Daniele; Baldi, Nicola; Distante, Alessandro; Piscitelli, Prisco

    2013-01-01

    Background: Osteoporosis is a leading cause of morbidity in patients affected by β-thalassemia major or intermediate; we aimed to assess the association between demineralization observed in young thalassemic patients. Methods: A total of 88 patients with β-thalassemia were recruited at Microcitemia Center of Taranto Hospital under the Prevention Osteoporosis and Fractures research project from 2008 to 2010. All the patients were screened with both dual energy x-ray absorptiometry (DXA) and quantitative ultrasound (QUS). T score and Z score values were obtained for each subject. Results: The overall prevalence of demineralization was 84% with DXA and 70% with QUS, whereas normality was found in 16% of patients screened with DXA and in 30% of cases with QUS. Hypogonadism, hypothyroidism, diabetes mellitus, hepatitis-B, and the presence of previous fragility fractures were significantly associated with the demineralization status (lower T scores values) both with DXA and QUS. Conclusion: Our data confirm that DXA and QUS examinations are both useful for detecting bone demineralization in thalassemic patients. PMID:23652868

  13. Reference standards for lean mass measures using GE dual energy x-ray absorptiometry in Caucasian adults.

    PubMed

    Imboden, Mary T; Swartz, Ann M; Finch, Holmes W; Harber, Matthew P; Kaminsky, Leonard A

    2017-01-01

    To develop reference values by age and sex for LM measures using GE-Healthcare DXA systems. A de-identified sample was obtained from Ball State University's Clinical Exercise Physiology Laboratory and University of Wisconsin-Milwaukee's Physical Activity & Health Research Laboratory. DXA scans of 2,076 women and 1,251 men were completed using a GE Lunar Prodigy or iDXA. Percentiles (%ile) were calculated for all variables of interest (LM, LMI, %LM, and ALMI) and a factorial ANOVA was used to assess differences for each variable between 10-year age groups and sex, as well as the interaction between age and sex. Men had higher mean total LM, %LM, LMI, and ALMI than women (p<0.01), across all age groups. All LM variables decreased significantly over the 5 decades in men, however in women only total LM, %LM, and ALMI decreased from the youngest to oldest age groups (p<0.01). These reference values provide for a more accurate interpretation of GE-Healthcare DXA-derived LM measurements offering clinicians and researchers with an initial resource to aid in the early detection and assessment of LM deficits.

  14. BMI and an Anthropometry-Based Estimate of Fat Mass Percentage Are Both Valid Discriminators of Cardiometabolic Risk: A Comparison with DXA and Bioimpedance

    PubMed Central

    Völgyi, Eszter; Savonen, Kai; Tylavsky, Frances A.; Alén, Markku; Cheng, Sulin

    2013-01-01

    Objective. To determine whether categories of obesity based on BMI and an anthropometry-based estimate of fat mass percentage (FM% equation) have similar discriminative ability for markers of cardiometabolic risk as measurements of FM% by dual-energy X-ray absorptiometry (DXA) or bioimpedance analysis (BIA). Design and Methods. A study of 40–79-year-old male (n = 205) and female (n = 388) Finns. Weight, height, blood pressure, triacylglycerols, HDL cholesterol, and fasting blood glucose were measured. Body composition was assessed by DXA and BIA and a FM%-equation. Results. For grade 1 hypertension, dyslipidaemia, and impaired fasting glucose >6.1 mmol/L, the categories of obesity as defined by BMI and the FM% equation had 1.9% to 3.7% (P < 0.01) higher discriminative power compared to DXA. For grade 2 hypertension the FM% equation discriminated 1.2% (P = 0.05) lower than DXA and 2.8% (P < 0.01) lower than BIA. Receiver operation characteristics confirmed BIA as best predictor of grade 2 hypertension and the FM% equation as best predictor of grade 1 hypertension. All other differences in area under curve were small (≤0.04) and 95% confidence intervals included 0. Conclusions. Both BMI and FM% equations may predict cardiometabolic risk with similar discriminative ability as FM% measured by DXA or BIA. PMID:24455216

  15. Assessment of body composition by dual-energy X-ray absorptiometry, bioimpedance analysis and anthropometrics in children: the Physical Activity and Nutrition in Children study.

    PubMed

    Tompuri, Tuomo T; Lakka, Timo A; Hakulinen, Mikko; Lindi, Virpi; Laaksonen, David E; Kilpeläinen, Tuomas O; Jääskeläinen, Jarmo; Lakka, Hanna-Maaria; Laitinen, Tomi

    2015-01-01

    We compared InBody720 segmental multifrequency bioimpedance analysis (SMF-BIA) with Lunar Prodigy Advance dual-energy X-ray absorptiometry (DXA) in assessment of body composition among 178 predominantly prepubertal children. Segmental agreement analysis of body compartments was carried out, and inter-relationships of anthropometric and other measures of body composition were defined. Moreover, the relations of different reference criteria for excess body fat were evaluated. The prevalence of excess body fat varies greatly according to the used criteria. Intraclass and Pearson's correlations between SMF-BIA and DXA were >0·92 in total body and >0·74 in regional measures. SMF-BIA underestimated percentage body fat (%BF) and fat mass (FM), and overestimated lean mass (LM) and percentage LM with significant offset trend bias. Higher adiposity increased offsets, and overall agreement was poorer in girls. On average, %BF offsets (girls/boys) and limits of agreement (LA) were 3·9/1·6% [(-)1·4-9·2%/(-)3·4-6·7%]. Interestingly percentage offsets of fat content (%BF: 18·9/10·1%, FM: 18·8/11·1%) showed no significant bias trends indicating that the corresponding absolute methodological offset depends on the amount of fat content. The smallest percentage offset was found with LM: 4·3/0·1%, referring offset (LA) of 0·88/0·03 kg (±2·05/±1·71 kg). Correspondingly, segmental LM had poorer agreement than total body LM. All anthropometrics except for the waist-to-hip ratio showed strong correlations (r = 0·76-0·95) with abdominal and total body fat. Segmental multifrequency bioimpedance analysis is precise enough for total-LM analysis and had also sufficient trueness for total body composition analysis to be used in epidemiological purposes. There is need to generate scientifically and clinically relevant criteria and reference values for excess body fat. © 2013 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley

  16. Accuracy of DXA scanning of the thoracic spine: cadaveric studies comparing BMC, areal BMD and geometric estimates of volumetric BMD against ash weight and CT measures of bone volume.

    PubMed

    Sran, Meena M; Khan, Karim M; Keiver, Kathy; Chew, Jason B; McKay, Heather A; Oxland, Thomas R

    2005-12-01

    Biomechanical studies of the thoracic spine often scan cadaveric segments by dual energy X-ray absorptiometry (DXA) to obtain measures of bone mass. Only one study has reported the accuracy of lateral scans of thoracic vertebral bodies. The accuracy of DXA scans of thoracic spine segments and of anterior-posterior (AP) thoracic scans has not been investigated. We have examined the accuracy of AP and lateral thoracic DXA scans by comparison with ash weight, the gold-standard for measuring bone mineral content (BMC). We have also compared three methods of estimating volumetric bone mineral density (vBMD) with a novel standard-ash weight (g)/bone volume (cm3) as measured by computed tomography (CT). Twelve T5-T8 spine segments were scanned with DXA (AP and lateral) and CT. The T6 vertebrae were excised, the posterior elements removed and then the vertebral bodies were ashed in a muffle furnace. We proposed a new method of estimating vBMD and compared it with two previously published methods. BMC values from lateral DXA scans displayed the strongest correlation with ash weight (r=0.99) and were on average 12.8% higher (p<0.001). As expected, BMC (AP or lateral) was more strongly correlated with ash weight than areal bone mineral density (aBMD; AP: r=0.54, or lateral: r=0.71) or estimated vBMD. Estimates of vBMD with either of the three methods were strongly and similarly correlated with volumetric BMD calculated by dividing ash weight by CT-derived volume. These data suggest that readily available DXA scanning is an appropriate surrogate measure for thoracic spine bone mineral and that the lateral scan might be the scan method of choice.

  17. Body composition measured by dual-energy X-ray absorptiometry in patients who have undergone small-intestinal resection.

    PubMed

    Haderslev, Kent Valentin; Jeppesen, Paller Bekker; Sorensen, Henrik Ancher; Mortensen, Per Brobech; Staun, Michael

    2003-07-01

    Patients who have undergone resection of the small intestine have lower body weight than do healthy persons. It remains unclear whether it is the body fat mass or the lean tissue mass that is reduced. We compared body-composition values in patients who had undergone small-intestinal resection with reference values obtained in healthy volunteers, and we studied the relation between body-composition estimates and the net intestinal absorption of energy. In a cross-sectional study, we included 20 men and 24 women who had undergone small-intestinal resection and had malabsorption of energy > 2000 kJ/d. Diagnoses were Crohn disease (n = 37) and other conditions (n = 7). Body composition was estimated by dual-energy X-ray absorptiometry, and data were compared with those from a reference group of 173 healthy volunteers. Energy absorption was measured during 48-h balance studies by using bomb calorimetry, and individual values were expressed relative to the basal metabolic rate. Body weight and body mass index in patients were significantly (P < 0.05) lower than the reference values. Fat mass was 6.4 kg (30%) lower (95% CI: -8.8, -3.9 kg), but lean tissue mass was only slightly and insignificantly lower (1.5 kg, or 3.3%; 95% CI: -3.7, 0.60 kg). Weight, body mass index, and body-composition estimates by dual-energy X-ray absorptiometry did not correlate significantly with the net energy absorption relative to the basal metabolic rate, expressed as a percentage. Patients who had undergone small-intestinal resection had significantly lower body weights and body mass indexes than did healthy persons, and they had significant changes in body composition, mainly decreased body fat mass.

  18. Anthropometric Variables Accurately Predict Dual Energy X-Ray Absorptiometric-Derived Body Composition and Can Be Used to Screen for Diabetes

    PubMed Central

    Yavari, Reza; McEntee, Erin; McEntee, Michael; Brines, Michael

    2011-01-01

    The current world-wide epidemic of obesity has stimulated interest in developing simple screening methods to identify individuals with undiagnosed diabetes mellitus type 2 (DM2) or metabolic syndrome (MS). Prior work utilizing body composition obtained by sophisticated technology has shown that the ratio of abdominal fat to total fat is a good predictor for DM2 or MS. The goals of this study were to determine how well simple anthropometric variables predict the fat mass distribution as determined by dual energy x-ray absorptometry (DXA), and whether these are useful to screen for DM2 or MS within a population. To accomplish this, the body composition of 341 females spanning a wide range of body mass indices and with a 23% prevalence of DM2 and MS was determined using DXA. Stepwise linear regression models incorporating age, weight, height, waistline, and hipline predicted DXA body composition (i.e., fat mass, trunk fat, fat free mass, and total mass) with good accuracy. Using body composition as independent variables, nominal logistic regression was then performed to estimate the probability of DM2. The results show good discrimination with the receiver operating characteristic (ROC) having an area under the curve (AUC) of 0.78. The anthropometrically-derived body composition equations derived from the full DXA study group were then applied to a group of 1153 female patients selected from a general endocrinology practice. Similar to the smaller study group, the ROC from logistical regression using body composition had an AUC of 0.81 for the detection of DM2. These results are superior to screening based on questionnaires and compare favorably with published data derived from invasive testing, e.g., hemoglobin A1c. This anthropometric approach offers promise for the development of simple, inexpensive, non-invasive screening to identify individuals with metabolic dysfunction within large populations. PMID:21915276

  19. Longitudinal Changes in Body Composition Assessed Using DXA and Surface Anthropometry Show Good Agreement in Elite Rugby Union Athletes.

    PubMed

    Zemski, Adam J; Keating, Shelley E; Broad, Elizabeth M; Slater, Gary J

    2018-05-14

    Rugby union athletes have divergent body composition based on the demands of their on-field playing position and ethnicity. With an established association between physique traits and positional requirements, body composition assessment is routinely undertaken. Surface anthropometry and dual-energy X-ray absorptiometry (DXA) are the most common assessment techniques utilised, often undertaken synchronously. This study aims to investigate the association between DXA and surface anthropometry when assessing longitudinal changes in fat free mass (FFM) and fat mass (FM) in rugby union athletes. Thirty-nine elite male rugby union athletes (age 25.7 ± 3.1 years; stature 187.6 ± 7.7 cm; mass 104.1 ± 12.2 kg) underwent assessment via DXA and surface anthropometry multiple times over three consecutive international seasons. Changes in the lean mass index (LMI), an empirical measure to assess proportional variation in FFM, showed large agreement with changes in DXA FFM (r=0.54, SEE=1.5%, P<0.001); the strength of association stronger amongst forwards (r=0.63) compared with backs (r=0.38). Changes in the sum of 7 skinfolds (S7SF) showed very large agreement with changes in DXA FM (r=0.73, SEE=5.8%, P<0.001), with meaningful differences observed regardless of ethnicity (Caucasians r=0.75; Polynesians r=0.62). The LMI and S7SF were able to predict the direction of change in FFM and FM, respectively, 86% and 91% of the time when DXA change was >1kg. Surface anthropometry measures provide a robust indication of the direction of change in FFM and FM, although caution may need to be applied when interpreting magnitude of change, particularly with FM.

  20. In vivo body composition in autochthonous and conventional pig breeding groups by dual-energy X-ray absorptiometry and magnetic resonance imaging under special consideration of Cerdo Ibérico.

    PubMed

    Kremer, P V; Fernández-Fígares, I; Förster, M; Scholz, A M

    2012-12-01

    The improvement of carcass quality is one of the main breeding goals in pig production. To select appropriate breeding animals, it is of major concern to exactly and reliably analyze the body composition in vivo. Therefore, the objective of the study was to examine whether the combination of dual-energy X-ray absorptiometry (DXA) and magnetic resonance imaging (MRI) offers the opportunity to reliably analyze quantitative and qualitative body composition characteristics of different pig breeding groups in vivo. In this study, a total of 77 pigs were studied by DXA and MRI at an average age of 154 days. The pigs originated from different autochthonous or conventional breeds or crossbreeds and were grouped into six breed types: Cerdo Ibérico (Ib); Duroc × Ib (Du_Ib); White Sow Lines (WSL, including German Landrace and German Large White); Hampshire/Pietrain (Pi_Ha, including Hampshire, Pietrain × Hampshire (PiHa) and Pietrain × PiHa); Pietrain/Duroc (Pi_Du, including Pietrain × Duroc (PiDu) and Pietrain × PiDu); crossbred WSL (PiDu_WSL, including Pietrain × WSL and PiDu × WSL). A whole-body scan was performed by DXA with a GE Lunar DPX-IQ in order to measure the amount and percentage of fat tissue (FM; %FM), lean tissue (LM; %LM) and bone mineral, whereas a Siemens Magnetom Open with a large body coil was used for MRI in the thorax region between 13th and 14th vertebrae in order to measure the area of the loin (LA) and the above back fat area (FA) of both body sides. A GLM procedure using SAS 9.2 was used to analyze the data. As expected, the native breed Ib followed by Du_Ib crossbreeds showed the highest %FM (27.2%, 25.0%) combined with the smallest LA (46.2 cm2, 73.6 cm2), whereas Ib had the lowest BW at an average age of 154 days. Pigs with Pi_Ha origin presented the least %FM (12.4%) and largest LA (99.5 cm2). The WSL and PiDu_WSL showed an intermediate body composition. Therefore, it could be concluded that DXA and MRI and especially their combination

  1. Comparison of Methods for Assessing Body Composition Changes during Weight Loss.

    ERIC Educational Resources Information Center

    Weyers, Anna M.; Mazzetti, Scott A.; Love, Dawn M.; Gomez, Ana L.; Kraemer, William J.; Volek, Jeff S.

    2002-01-01

    Investigated whether dual-energy x-ray absorptiometry (DXA) and air displacement plethysmography (ADP) would detect similar changes in body composition after moderate weight loss. Twenty adults had their body composition measured using DXA and ADP before and after an 8-week weight loss program. Overall, both DXA and ADP detected similar changes in…

  2. Body fat in children measured by DXA, air-displacement plethysmography, TBW and multicomponent models: a systematic review.

    PubMed

    Zanini, Roberta de Vargas; Santos, Iná S; Chrestani, Maria Aurora D; Gigante, Denise Petrucci

    2015-07-01

    To conduct a systematic literature review to identify studies that used indirect methods to assess body fat in healthy children. A systematic review was conducted according to the PRISMA guidelines. We conducted a search in the MEDLINE/PubMed, SciELO and Google Scholar databases. Studies in healthy children aged 0-9 years were eligible for inclusion. Studies were kept or excluded from the review according to eligibility criteria defined a priori. Two independent reviewers conducted all steps in the study selection. Initially, 11,246 articles were retrieved, with 3,593 duplicates. After applying the eligibility criteria, 22 articles were selected for review. The methodology of each study was analyzed by each reviewer individually. The indirect methods used to assess body fat in children included dual-energy X-ray absorptiometry (DXA) (14 articles), air-displacement plethysmography (five articles), multicomponent models (two articles), and total body water (one article). Most studies reported absolute (in kilograms) or relative (percentage) body fat measures. Only seven studies reported the fat mass index (FMI) (kg/m(2)). DXA was the indirect method most frequently used to assess body fat in healthy children. FMI was seldom reported.

  3. Automation of a DXA-based finite element tool for clinical assessment of hip fracture risk.

    PubMed

    Luo, Yunhua; Ahmed, Sharif; Leslie, William D

    2018-03-01

    Finite element analysis of medical images is a promising tool for assessing hip fracture risk. Although a number of finite element models have been developed for this purpose, none of them have been routinely used in clinic. The main reason is that the computer programs that implement the finite element models have not been completely automated, and heavy training is required before clinicians can effectively use them. By using information embedded in clinical dual energy X-ray absorptiometry (DXA), we completely automated a DXA-based finite element (FE) model that we previously developed for predicting hip fracture risk. The automated FE tool can be run as a standalone computer program with the subject's raw hip DXA image as input. The automated FE tool had greatly improved short-term precision compared with the semi-automated version. To validate the automated FE tool, a clinical cohort consisting of 100 prior hip fracture cases and 300 matched controls was obtained from a local community clinical center. Both the automated FE tool and femoral bone mineral density (BMD) were applied to discriminate the fracture cases from the controls. Femoral BMD is the gold standard reference recommended by the World Health Organization for screening osteoporosis and for assessing hip fracture risk. The accuracy was measured by the area under ROC curve (AUC) and odds ratio (OR). Compared with femoral BMD (AUC = 0.71, OR = 2.07), the automated FE tool had a considerably improved accuracy (AUC = 0.78, OR = 2.61 at the trochanter). This work made a large step toward applying our DXA-based FE model as a routine clinical tool for the assessment of hip fracture risk. Furthermore, the automated computer program can be embedded into a web-site as an internet application. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. [Dual x-ray absorptiometry assessment of bone density of the proximal tibia in advanced-stage degenerative disease of the knee].

    PubMed

    Hulet, C; Sabatier, J P; Schiltz, D; Locker, B; Marcelli, C; Vielpeau, C

    2001-02-01

    Axial deformity secondary to degenerative joint disease of the knee can modify stress forces. Certain studies have reported an inversely proportional relationship between degenerative disease and osteoporosis. The aim of this prospective study was to quantify the horizontal linear distribution of bone density using dual x-ray absorptiometry (DXA) of the proximal tibia as a function of the femoral neck bone density in patients with knee osteoarthritis. Between September 1996 and March 1998, 90 cases of primary degenerative joint disease of the knee were programmed for total knee arthroplasty. Prior to the procedure, the patients were assessed clinically and radiologically according to the International Knee Society (IKS) criteria. The mechanical femorotibial angle was measured in all patients and the varus angles were recorded. Most of the patients were women (65 p. 100) with a mean age of 70 +/- 5 years. Valgus knees were excluded from this series. The mean mechanical femorotibial angle was 172 +/- 5 degrees. Fifteen patients had a normal axis (16 p. 100), 32 had a varus measuring 4 degrees to 10 degrees (35 p. 100) and 43 had a varus measuring 10 degrees or more (48 p. 100). The overall varus distance was 6.4 +/- 2 cm. All patients had two DXA explorations: femoral neck to determine the bone status according to the WHO criteria (normal, osteopenia, osteoporosis), knee to determine the linear distribution of bone density of the proximal tibia. A 7 mm high band including 7 regions of interest covering the width of the tibia were explored in the area where the tibial cut was to be made. These 7 regions of interest were: R1, R2 under the lateral compartment, R6, R7 under the medial compartment, and R3, R4, R5 on either side of the tibial spines. The level of significance was set at 5 p. 100. The mean Z score (0.54 +/- 1) in the 90 patients showed a symmetrical distribution. These patients were representative of their age range. Their T score was - 1.40 +/- 1 (m +/- SD

  5. HDL subclasses are heterogeneous in their associations with body fat, as measured by dual-energy X-ray absorptiometry: the Kitakata Kids Health Study.

    PubMed

    Kouda, Katsuyasu; Nakamura, Harunobu; Fujita, Yuki; Hamada, Masami; Kajita, Etsuko; Nakatani, Yoshimi; Sato, Yuho; Uenishi, Kazuhiro; Iki, Masayuki

    2015-04-15

    Obesity, defined as the excessive accumulation of body fat, is frequently associated with low concentrations of high-density lipoprotein (HDL) cholesterol. However, HDL particles are heterogeneous in size and composition. HDL subclasses may be differentially associated with body fat. This study investigated associations between the cholesterol concentrations of HDL subclasses, as determined by high-performance liquid chromatography, and body fat variables, as measured by dual-energy X-ray absorptiometry. The source population was all ninth grade students who attended Shiokawa Junior High School in Japan. Cross-sectional data on body fat and serum HDL subclasses were obtained for 87 students (72.5% of the source population). The cholesterol concentration of the large HDL subclass showed a significant (P<0.05) inverse relationship with whole body fat and trunk fat (r=-0.24 and -0.30), whereas the concentration of the small HDL subclass showed a significant positive relationship with these body fat variables (r=0.25 and 0.31). After adjusting for potential confounding factors, the mean concentration of small HDL significantly increased from the lowest to highest tertiles of trunk fat mass index. These results indicate that HDL subclasses are heterogeneous in their associations with body fat variables that were accurately measured by dual-energy X-ray absorptiometry among Japanese students. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Use of iDXA spine scans to evaluate total and visceral abdominal fat.

    PubMed

    Bea, J W; Hsu, C-H; Blew, R M; Irving, A P; Caan, B J; Kwan, M L; Abraham, I; Going, S B

    2018-01-01

    Abdominal fat may be a better predictor than body mass index (BMI) for risk of metabolically-related diseases, such as diabetes, cardiovascular disease, and some cancers. We sought to validate the percent fat reported on dual energy X-ray absorptiometry (DXA) regional spine scans (spine fat fraction, SFF) against abdominal fat obtained from total body scans using the iDXA machine (General Electric, Madison, WI), as previously done on the Prodigy model. Total body scans and regional spine scans were completed on the same day (N = 50). In alignment with the Prodigy-based study, the following regions of interest (ROI) were assessed from total body scans and compared to the SFF from regional spine scans: total abdominal fat at (1) lumbar vertebrae L2-L4 and (2) L2-Iliac Crest (L2-IC); (3) total trunk fat; and (4) visceral fat in the android region. Separate linear regression models were used to predict each total body scan ROI from SFF; models were validated by bootstrapping. The sample was 84% female, a mean age of 38.5 ± 17.4 years, and mean BMI of 23.0 ± 3.8 kg/m 2 . The SFF, adjusted for BMI, predicted L2-L4 and L2-IC total abdominal fat (%; Adj. R 2 : 0.90) and total trunk fat (%; Adj. R 2 : 0.88) well; visceral fat (%) adjusted R 2 was 0.83. Linear regression models adjusted for additional participant characteristics resulted in similar adjusted R 2 values. This replication of the strong correlation between SFF and abdominal fat measures on the iDXA in a new population confirms the previous Prodigy model findings and improves generalizability. © 2017 Wiley Periodicals, Inc.

  7. Heel Ultrasound Can Assess Maintenance of Bone Mass in Women with Breast Cancer

    PubMed Central

    Langmann, Gabrielle A.; Vujevich, Karen T.; Medich, Donna; Miller, Megan E.; Perera, Subashan; Greenspan, Susan L.

    2016-01-01

    Postmenopausal women with early-stage breast cancer are at increased risk for bone loss and fractures. Bisphosphonates can prevent bone loss, but little data are available on changes in bone mass assessed by heel quantitative ultrasound (QUS). Our objectives were to determine if (1) heel QUS would provide a reliable and accessible method for evaluation of changes in bone mass in women with breast cancer as compared to the current standard of bone mass measurement, dual-energy x-ray absorptiometry (DXA), and (2) oral risedronate could affect these changes. Eighty-six newly postmenopausal (up to 8 years) women with nonmetastatic breast cancer were randomized to risedronate, 35 mg once weekly or placebo. Outcomes were changes in heel QUS bone mass measurements and conventional dual-energy x-ray absorptiometry (DXA) derived bone mineral density (BMD). Over 2 years, bone mass assessed by heel QUS remained stable in women on risedronate, while women on placebo had a 5.2% decrease (p ≤ 0.05) in heel QUS bone mass. Both total hip BMD and femoral neck BMD assessed by DXA decreased by 1.6% (p ≤ 0.05) in the placebo group and remained stable with risedronate. Spine BMD remained stable in both groups. Heel QUS was moderately associated with BMD measured by DXA at the total hip (r = 0.50), femoral neck (r = 0.40), and spine (r = 0.46) at baseline (all p ≤ 0.001). In conclusion, risedronate helps to maintain skeletal integrity as assessed by heel QUS for women with early-stage breast cancer. Heel QUS is associated with DXA-derived BMD at other major axial sites and may be used to follow skeletal health and bone mass changes in these women. PMID:22425507

  8. Changes in fat and skeletal muscle with exercise training in obese adolescents: comparison of whole-body MRI and dual energy X-ray absorptiometry

    PubMed Central

    Lee, SoJung; Kuk, Jennifer L.

    2013-01-01

    Objective We examined skeletal muscle (SM) and fat distribution using whole-body MRI in response to aerobic (AE) versus resistance exercise (RE) training in obese adolescents and whether DXA provides similar estimates of fat and SM change as MRI. Design and Methods Thirty-nine obese boys (12–18 yr) were randomly assigned to one of three 3-month interventions: AE (n=14), RE (n=14) or a control (n=11). Results At baseline, MRI-measured total fat was significantly greater than DXA-measured total fat [Δ=3.1 kg (95% CI: −0.4 to 7.4 kg, P<0.05)], wherein underestimation by DXA was greatest in those with the highest total fat. Overall, the changes in total fat were not significantly different between MRI and DXA [Δ= −0.4 kg (95% CI: −3.5 to 2.6 kg, P>0.05)], but DXA tended to overestimate MRI fat losses in those with larger fat losses. MRI-measured SM and DXA-measured LBM (lean body mass) were significantly correlated, but as expected the absolute values were different at baseline [Δ= −28.4 kg (95% CI: −35.4 to −21.3 kg, P<0.05)]. Further, DXA overestimated MRI gains in SM in those with larger SM gains. Conclusions Although DXA and MRI-measured total and regional measures tended to be correlated at baseline and changes with exercise, there were substantial differences in the absolute values derived using DXA versus MRI. Further, there were systemic biases in the estimation between the methods wherein DXA tended to overestimate fat losses and SM gains compared to MRI. Thus, the changes in body composition observed are influenced by the method employed. PMID:23512818

  9. X-ray vector radiography imaging for biomedical applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Potdevin, Guillaume; Malecki, Andreas; Biernath, Thomas

    The non-invasive estimation of fracture risk in osteoporosis remains a challenge in the clinical routine and is mainly based on an assessment of bone density by dual X-ray absorption (DXA) although bone micro-architecture is known to play an important role for bone fragility. Here we report on 'X-ray vector Radiography' measurements able to provide a direct bone microstructure diagnostics on human bone samples, which we compare qualitatively and quantitatively with numerical analysis of high resolution radiographs.

  10. Human immunodeficiency virus-associated lipodystrophy: an objective definition based on dual-energy x-ray absorptiometry-derived regional fat ratios in a South Asian population.

    PubMed

    Asha, Hesarghatta Shyamasunder; Seshadri, Mandalam Subramaniam; Paul, Thomas Vizhalil; Abraham, Ooriapadickal Cherian; Rupali, Priscilla; Thomas, Nihal

    2012-01-01

    To develop an objective definition of human immunodeficiency virus (HIV)-associated lipodystrophy by using regional fat mass ratios and to assess the utility of anthropometric and skinfold measurements in the initial screening for lipodystrophy. Male patients between 25 and 50 years old with proven HIV infection (highly active antiretroviral therapy [HAART]-naïve subjects and those receiving successful HAART) were studied and compared with body mass index (BMI)-matched HIV-negative control subjects. Anthropometric variables, body composition, dual-energy x-ray absorptiometry findings, and metabolic variables were compared among the 3 study groups and between those patients with and those without lipodystrophy. Trunk fat/lower limb fat mass ratio >2.28 identified 54.3% of patients with HIV receiving HAART as having lipodystrophy and had the highest odds ratio for predicting metabolic syndrome. The "clinical diagnosis of lipodystrophy" and the "clinical scoring system" had too many false-positive and false-negative results. Triceps skinfold thickness (SFT)/BMI ratio ≤0.49 and abdominal SFT/triceps SFT ratio >1.385 have good sensitivity but poor specificity in identifying lipodystrophy. In comparison with HAART-naïve patients with HIV, those receiving HAART had significantly higher insulin resistance, and a significantly greater proportion had impaired glucose tolerance and dyslipidemia. Among patients receiving HAART, those with lipodystrophy had a greater degree of insulin resistance, higher triglyceride levels, and lower levels of high-density lipoprotein cholesterol. The trunk fat/lower limb fat mass ratio in BMI-matched normal subjects can be used to derive cutoff values to define lipodystrophy objectively in HIV-infected patients. Defining lipodystrophy in this way is better than other methods of identifying those patients with increased cardiovascular risk. Triceps SFT/BMI and abdominal SFT/triceps SFT ratios may be useful as screening tools in resource

  11. Miniature X-Ray Bone Densitometer

    NASA Technical Reports Server (NTRS)

    Charles, Harry K., Jr.

    1999-01-01

    The purpose of the Dual Energy X-ray Absorptiometry (DEXA) project is to design, build, and test an advanced X-ray absorptiometry scanner capable of being used to monitor the deleterious effects of weightlessness on the human musculoskeletal system during prolonged spaceflight. The instrument is based on the principles of dual energy x-ray absorptiometry and is designed not only to measure bone, muscle, and fat masses but also to generate structural information about these tissues so that the effects on mechanical integrity may be assessed using biomechanical principles. A skeletal strength assessment could be particularly important for an astronaut embarking on a remote planet where the consequences of a fragility fracture may be catastrophic. The scanner will employ multiple projection images about the long axis of the scanned subject to provide geometric properties in three dimensions, suitable for a three-dimensional structural analysis of the scanned region. The instrument will employ advanced fabrication techniques to minimize volume and mass (100 kg current target with a long-term goal of 60 kg) of the scanner as appropriate for the space environment, while maintaining the required mechanical stability for high precision measurement. The unit will have the precision required to detect changes in bone mass and geometry as small as 1% and changes in muscle mass as small as 5%. As the system evolves, advanced electronic fabrication technologies such as chip-on-board and multichip modules will be combined with commercial (off-the-shelf) parts to produce a reliable, integrated system which not only minimizes size and weight, but, because of its simplicity, is also cost effective to build and maintain. Additionally, the system is being designed to minimize power consumption. Methods of heat dissipation and mechanical stowage (for the unit when not in use) are being optimized for the space environment.

  12. Magnetic resonance imaging of the calcaneus: preliminary assessment of trabecular bone-dependent regional variations in marrow relaxation time compared with dual X-ray absorptiometry

    NASA Technical Reports Server (NTRS)

    Guglielmi, G.; Selby, K.; Blunt, B. A.; Jergas, M.; Newitt, D. C.; Genant, H. K.; Majumdar, S.

    1996-01-01

    RATIONALE AND OBJECTIVES: Marrow transverse relaxation time (T2*) in magnetic resonance (MR) imaging may be related to the density and structure of the surrounding trabecular network. We investigated regional variations of T2* in the human calcaneus and compared the findings with bone mineral density (BMD), as measured by dual X-ray absorpiometry (DXA). Short- and long-term precisions were evaluated first to determine whether MR imaging would be useful for the clinical assessment of disease status and progression in osteoporosis. METHODS: Gradient-recalled echo MR images of the calcaneus were acquired at 1.5 T from six volunteers. Measurements of T2* were compared with BMD and (for one volunteer) conventional radiography. RESULTS: T2* values showed significant regional variation; they typically were shortest in the superior region of the calcaneus. There was a linear correlation between MR and DXA measurements (r = .66 for 1/T2* versus BMD). Differences in T2* attributable to variations in analysis region-of-interest placement were not significant for five of the six volunteers. Sagittal MR images had short- and long-term precision errors of 4.2% and 3.3%, respectively. For DXA, the precision was 1.3% (coefficient of variation). CONCLUSION: MR imaging may be useful for trabecular bone assessment in the calcaneus. However, given the large regional variations in bone density and structure, the choice of an ROI is likely to play a major role in the accuracy, precision, and overall clinical efficacy of T2* measurements.

  13. Correspondence between theoretical models and dual energy x-ray absorptiometry measurements of femoral cross-sectional growth during adolescence

    NASA Technical Reports Server (NTRS)

    van der Meulen, M. C.; Marcus, R.; Bachrach, L. K.; Carter, D. R.

    1997-01-01

    We have developed an analytical model of long bone cross-sectional ontogeny in which appositional growth of the diaphysis is primarily driven by mechanical stimuli associated with increasing body mass during growth and development. In this study, our goal was to compare theoretical predictions of femoral diaphyseal structure from this model with measurements of femoral bone mineral and geometry by dual energy x-ray absorptiometry. Measurements of mid-diaphyseal femoral geometry and structure were made previously in 101 Caucasian adolescents and young adults 9-26 years of age. The data on measured bone mineral content and calculated section modulus were compared with the results of our analytical model of cross-sectional development of the human femur over the same age range. Both bone mineral content and section modulus showed good correspondence with experimental measurements when the relationships with age and body mass were examined. Strong linear relationships were evident for both parameters when examined as a function of body mass.

  14. Comparison of Muscle Mass Indices Using Computed Tomography or Dual X-Ray Absorptiometry for Predicting Physical Performance in Hemodialysis Patients.

    PubMed

    Kang, Seok Hui; Lee, Hyun Seok; Lee, Sukyung; Cho, Ji-Hyung; Kim, Jun Chul

    2017-01-01

    Our study aims to evaluate the association between thigh muscle cross-sectional area (TMA) using computed tomography (CT), or appendicular skeletal muscle mass (ASM) using dual energy X-ray absorptiometry (DEXA), and physical performance levels in hemodialysis (HD) patients. Patients were included if they were on HD for ≥6 months (n = 84). ASM and TMA were adjusted to body weight (BW, kg) or height2 (Ht2, m2). Each participant performed a short physical performance battery test (SPPB), a sit-to-stand for 30 second test (STS30), a 6-minute walk test (6-MWT), a timed up and go test (TUG), and hand grip strength (HGS) test. Correlation coefficients for SPPB, GS, 5STS, STS30, 6-MWT, and TUG were highest in TMA/BW. Results from partial correlation or linear regression analyses displayed similar trends to those derived from Pearson's correlation analyses. An increase in TMA/BW or TMA/Ht2 was associated with a decreased odds ratio of low SPPB, GS, or HGS in multivariate analyses. Indices using DEXA were associated with a decreased odds ratio of a low HGS only in multivariate analysis. TMA indices using CT may be more valuable in predicting physical performance or strength in HD patients. © 2017 The Author(s). Published by S. Karger AG, Basel.

  15. Neonatal anthropometrics and body composition in obese children investigated by dual energy X-ray absorptiometry.

    PubMed

    Lausten-Thomsen, Ulrik; Nielsen, Tenna Ruest Haarmark; Thagaard, Ida Näslund; Larsen, Torben; Holm, Jens-Christian

    2014-05-01

    Epidemiological and animal studies have suggested an effect of the intrauterine milieu upon the development of childhood obesity. This study investigates the relationship between body composition measured by dual energy X-ray absorptiometry expressed as body fat percent, body fat mass index (BFMI), and fat free mass index (FFMI) in obese children and the preceding in utero conditions expressed by birth weight, birth length, and birth weight for gestational age. The study cohort consisted of 776 obese Danish children (median age 11.6 years, range 3.6-17.9) with a mean Body Mass Index Standard Deviation Score (BMI SDS) of 2.86 (range 1.64-5.48) treated in our national referral centre. In a linear general regression model adjusted for age, gender, socioeconomic status, and duration of breastfeeding, we found the body fat percent, FFMI, and BFMI at the time of enrolment in childhood obesity treatment to be significantly correlated with both birth weight and birth weight for gestational age. These results indicate a prenatal influence upon childhood obesity. Although there are currently no sufficient data to suggest any recommendations to pregnant women, it is possible that the prenatal period may be considered as a potential window of opportunity for prevention of childhood overweight and obesity.

  16. Individual Trabecula Segmentation (ITS)-Based Morphological Analyses and Micro Finite Element Analysis of HR-pQCT Images Discriminate Postmenopausal Fragility Fractures Independent of DXA Measurements

    PubMed Central

    Liu, X. Sherry; Stein, Emily M.; Zhou, Bin; Zhang, Chiyuan A.; Nickolas, Thomas L.; Cohen, Adi; Thomas, Valerie; McMahon, Donald J.; Cosman, Felicia; Nieves, Jeri; Shane, Elizabeth; Guo, X. Edward

    2011-01-01

    Osteoporosis is typically diagnosed by dual energy x-ray absorptiometry (DXA) measurements of areal bone mineral density (aBMD). Emerging technologies, such as high-resolution peripheral quantitative computed tomography (HR-pQCT), may increase the diagnostic accuracy of DXA and enhance our mechanistic understanding of decreased bone strength in osteoporosis. Women with (n=68) and without (n=101) a history of postmenopausal fragility fracture had aBMD measured by DXA, trabecular plate and rod microarchitecture measured by HR-pQCT image-based individual trabeculae segmentation (ITS) analysis, and whole bone and trabecular bone stiffness by micro finite element analysis (μFEA) of HR-pQCT images at the radius and tibia. DXA T-scores were similar in women with and without fractures at the spine, hip and 1/3 radius, but lower in fracture subjects at the ultradistal radius. Trabecular microarchitecture of fracture subjects was characterized by preferential reductions in trabecular plate bone volume, number, and connectivity over rod trabecular parameters, loss of axially aligned trabeculae, and a more rod-like trabecular network. In addition, decreased thickness and size of trabecular plates were observed at the tibia. The differences between groups were greater at the radius than the tibia for plate number, rod bone volume fraction and number and plate-rod and rod-rod junction densities. Most differences between groups remained after adjustment for T-score by DXA. At a fixed bone volume fraction, trabecular plate volume, number and connectivity were directly associated with bone stiffness. In contrast, rod volume, number and connectivity were inversely associated with bone stiffness. In summary, HR-pQCT-based ITS and μFEA measurements discriminate fracture status in postmenopausal women independent of DXA measurements. Moreover, these results suggest that preferential loss of plate-like trabeculae contribute to lower trabecular bone and whole bone stiffness in women

  17. Adolescent exercise associated with long-term superior measures of bone geometry: a cross-sectional DXA and MRI study.

    PubMed

    Kato, T; Yamashita, T; Mizutani, S; Honda, A; Matumoto, M; Umemura, Y

    2009-12-01

    To investigate whether childhood sports participation, particularly weight-bearing sports, has any effect on bone mineral content (BMC), areal bone mineral density (aBMD) and bone geometric characteristics in middle-aged postmenopausal women. Design/ In this cross-sectional comparison of two groups, 46 middle-aged women (mean age, 60.2 (SD 5.6) years; range, 52-73 years) were grouped according to sport participation during growth: weight-bearing sports, including high-impact weight-bearing activities; and low-impact non-weight-bearing sports or no participation. Dual energy X-ray absorptiometry (DXA)-measured BMC, aBMD in the lumbar spine and femur. Magnetic resonance imaging (MRI) determined bone geometric characteristics in the femur, such as femoral mid-diaphyseal cross-sectional area, periosteal and endosteal perimeters and maximum and minimum second moment of area. Postmenopausal middle-aged women with participation in weight-bearing sports during junior high to high school (12-18 years old) displayed significantly greater BMC in both lumbar spine and femoral neck regions, and also significantly greater femoral mid-diaphyseal bone cross-sectional area, periosteal perimeter and maximum and minimum second moment of area than the non-weight-bearing sports group. Adolescent weight-bearing exercise exerts preservational effects on femoral mid-diaphyseal size and shape, while DXA-measured BMC effectively identified the same tendency. Weight-bearing exercise in youth affects bone, and these effects may be preserved as BMC, geometric and structural advantages even after 40 years.

  18. Effect of once-yearly zoledronic acid on the spine and hip as measured by quantitative computed tomography: results of the HORIZON Pivotal Fracture Trial

    PubMed Central

    Lang, T.; Boonen, S.; Cummings, S.; Delmas, P. D.; Cauley, J. A.; Horowitz, Z.; Kerzberg, E.; Bianchi, G.; Kendler, D.; Leung, P.; Man, Z.; Mesenbrink, P.; Eriksen, E. F.; Black, D. M.

    2016-01-01

    Summary Changes in bone mineral density and bone strength following treatment with zoledronic acid (ZOL) were measured by quantitative computed analysis (QCT) or dual-energy X-ray absorptiometry (DXA). ZOL treatment increased spine and hip BMD vs placebo, assessed by QCT and DXA. Changes in trabecular bone resulted in increased bone strength. Introduction To investigate bone mineral density (BMD) changes in trabecular and cortical bone, estimated by quantitative computed analysis (QCT) or dual-energy X-ray absorptiometry (DXA), and whether zoledronic acid 5 mg (ZOL) affects bone strength. Methods In 233 women from a randomized, controlled trial of once-yearly ZOL, lumbar spine, total hip, femoral neck, and trochanter were assessed by DXA and QCT (baseline, Month 36). Mean percentage changes from baseline and between-treatment differences (ZOL vs placebo, t-test) were evaluated. Results Mean between-treatment differences for lumbar spine BMD were significant by DXA (7.0%, p<0.01) and QCT (5.7%, p<0.0001). Between-treatment differences were significant for trabecular spine (p=0.0017) [non-parametric test], trabecular trochanter (10.7%, p<0.0001), total hip (10.8%, p<0.0001), and compressive strength indices at femoral neck (8.6%, p=0.0001), and trochanter (14.1%, p<0.0001). Conclusions Once-yearly ZOL increased hip and spine BMD vs placebo, assessed by QCT vs DXA. Changes in trabecular bone resulted in increased indices of compressive strength. PMID:19802508

  19. Cluster Masses Derived from X-ray and Sunyaev-Zeldovich Effect Measurements

    NASA Technical Reports Server (NTRS)

    Laroque, S.; Joy, Marshall; Bonamente, M.; Carlstrom, J.; Dawson, K.

    2003-01-01

    We infer the gas mass and total gravitational mass of 11 clusters using two different methods; analysis of X-ray data from the Chandra X-ray Observatory and analysis of centimeter-wave Sunyaev-Zel'dovich Effect (SZE) data from the BIMA and OVRO interferometers. This flux-limited sample of clusters from the BCS cluster catalogue was chosen so as to be well above the surface brightness limit of the ROSAT All Sky Survey; this is therefore an orientation unbiased sample. The gas mass fraction, f_g, is calculated for each cluster using both X-ray and SZE data, and the results are compared at a fiducial radius of r_500. Comparison of the X-ray and SZE results for this orientation unbiased sample allows us to constrain cluster systematics, such as clumping of the intracluster medium. We derive an upper limit on Omega_M assuming that the mass composition of clusters within r_500 reflects the universal mass composition Omega_M h_100 is greater than Omega _B / f-g. We also demonstrate how the mean f_g derived from the sample can be used to estimate the masses of clusters discovered by upcoming deep SZE surveys.

  20. In vivo precision of the GE Lunar iDXA densitometer for the measurement of total-body, lumbar spine, and femoral bone mineral density in adults.

    PubMed

    Hind, Karen; Oldroyd, Brian; Truscott, John G

    2010-01-01

    Knowledge of precision is integral to the monitoring of bone mineral density (BMD) changes using dual-energy X-ray absorptiometry (DXA). We evaluated the precision for bone measurements acquired using a GE Lunar iDXA (GE Healthcare, Waukesha, WI) in self-selected men and women, with mean age of 34.8 yr (standard deviation [SD]: 8.4; range: 20.1-50.5), heterogeneous in terms of body mass index (mean: 25.8 kg/m(2); SD: 5.1; range: 16.7-42.7 kg/m(2)). Two consecutive iDXA scans (with repositioning) of the total body, lumbar spine, and femur were conducted within 1h, for each subject. The coefficient of variation (CV), the root-mean-square (RMS) averages of SDs of repeated measurements, and the corresponding 95% least significant change were calculated. Linear regression analyses were also undertaken. We found a high level of precision for BMD measurements, particularly for scans of the total body, lumbar spine, and total hip (RMS: 0.007, 0.004, and 0.007 g/cm(2); CV: 0.63%, 0.41%, and 0.53%, respectively). Precision error for the femoral neck was higher but still represented good reproducibility (RMS: 0.014 g/cm(2); CV: 1.36%). There were associations between body size and total-body BMD and total-hip BMD SD precisions (r=0.534-0.806, p<0.05) in male subjects. Regression parameters showed good association between consecutive measurements for all body sites (r(2)=0.98-0.99). The Lunar iDXA provided excellent precision for BMD measurements of the total body, lumbar spine, femoral neck, and total hip. Copyright © 2010 The International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.

  1. Discriminatory ability of quantitative ultrasound parameters and bone mineral density in a population-based sample of postmenopausal women with vertebral fractures: results of the Basel Osteoporosis Study.

    PubMed

    Hartl, F; Tyndall, A; Kraenzlin, M; Bachmeier, C; Gückel, C; Senn, U; Hans, D; Theiler, R

    2002-02-01

    The discriminatory potential to classify subjects with or without vertebral fractures was tested cross-sectionally with different methods for the measurement of bone status in a population-based sample of postmenopausal women. Quantitative ultrasound (QUS) measurement at the calcaneus (Lunar Achilles, Hologic Sahara), the proximal phalanges (Igea Bone Profiler), and measurement of bone mineral density (BMD) with dual-energy X-ray absorptiometry (DXA; Lunar Expert) at several anatomic sites was performed in 500 postmenopausal women (aged 65-75 years) randomly selected from the population. In addition, 50 young female subjects (20-40 years old) had QUS measurements and served as controls to express QUS results as T-score values. Radiographs of the lumbar and thoracic spine were performed in the elderly women. Two independent radiologists reviewed the X-rays for the presence of vertebral fractures. Of 486 eligible study participants, no fracture was seen in 396 participants. Single vertebral fractures were observed in 71 subjects; 19 individuals presented multiple fractures. The overall prevalence of vertebral fractures was 18.5%. Participants without vertebral fractures were compared with subjects with vertebral fractures. Normal statistical distributions were found for all bone measurement results. Risk of vertebral fracture in subjects with no and multiple vertebral fracture was estimated using age adjusted odds ratios (ORs) for QUS and dual-energy X-ray absorptiometry (DXA) values. Each SD decrease in bone measurement increased the risk of multiple vertebral fracture by 3.0 (95% CI, 1.6-5.6) for the Achilles stiffness, by 3.8 (95% CI, 1.8-8.2) for the Sahara QUI, 2.1 (95% CI, 1.3-3.4) for the Bone Profiler amplitude-dependent speed of sound (AD-SOS), and 2.1 (95% CI, 1.2-3.9) and 2.4 (95% CI, 1.3-4.3) for DXA lumbar spine and for DXA total hip, respectively. Results of a discriminant analysis showed sensitivities between 84% and 58% and specificities between 72

  2. The role of hip and chest radiographs in osteoporotic evaluation among south Indian women population: a comparative scenario with DXA.

    PubMed

    Kumar, D Ashok; Anburajan, M

    2014-05-01

    Osteoporosis is recognized as a worldwide skeletal disorder problem. In India, the older as well as postmenopausal women population suffering from osteoporotic fractures has been a common issue. Bone mineral density measurements gauged by dual-energy X-ray absorptiometry (DXA) are used in the diagnosis of osteoporosis. (1) To evaluate osteoporosis in south Indian women by radiogrammetric method in a comparative perspective with DXA. (2) To assess the capability of KJH; Anburajan's Empirical formula in the prediction of total hip bone mineral density (T.BMD) with estimated Hologic T.BMD. In this cross-sectional design, 56 south Indian women were evaluated. These women were randomly selected from a health camp. The patients with secondary bone diseases were excluded. The standard protocol was followed in acquiring BMD of the right proximal femur by DPX Prodigy (DXA Scanner, GE-Lunar Corp., USA). The measured Lunar Total hip BMD was converted into estimated Hologic Total hip BMD. In addition, the studied population underwent chest and hip radiographic measurements. Combined cortical thickness of clavicle has been used in KJH; Anburajan's Empirical formula to predict T.BMD and compared with estimated Hologic T.BMD by DXA. The correlation coefficients exhibited high significance. The combined cortical thickness of clavicle and femur shaft of total studied population was strongly correlated with DXA femur T.BMD measurements (r = 0.87, P < 0.01 and r = 0.45, P < 0.01) and it is also having strong correlation with low bone mass group (r = 0.87, P < 0.01 and r = 0.67, P < 0.01) KJH; Anburajan's Empirical formula shows significant correlation with estimated Hologic T.BMD (r = 0.88, P < 0.01) in total studied population. The empirical formula was identified as better tool for predicting osteoporosis in total population and old-aged population with a sensitivity (88.8 and 95.6 %), specificity (89.6 and 90.9 %), positive predictive value (88.8 and 95.6 %) and negative

  3. Nuclear magnetic resonance for measurement of body composition in infants and children

    USDA-ARS?s Scientific Manuscript database

    Measurement of body composition in infants and children is currently challenging. Air Displacement Plethysmography (ADP) has not been validated between ages 6 mo and 6 y and the requirement for stillness of the Dual-energy X-ray Absorptiometry (DXA) technique limits its use. Quantitative Nuclear Ma...

  4. Should 25-hydroxyvitamin D and bone density using DXA be tested in adolescents with lumbar stress fractures of the pars interarticularis?

    PubMed

    McClellan, John W; Vernon, Brian A; White, Michael A; Stamm, Sarah; Ryschon, Kay L

    2012-12-01

    Retrospective study. To determine if 25-hydroxyvitamin D (25[OH]D) level measurement and bone mineral density (BMD) using dual-energy x-ray absorptiometry (DXA) are indicated in children with a history of stress fracture of the pars interarticularis. Healing rates of 4%-25% for bilateral and unilateral pars fractures, respectively, have previously been reported. Factors that may contribute to osteomalacia, rickets, and poor bone healing include low (25[OH]D) and low BMD. Patients were seen at the Nebraska Spine Center between 2008 and 2010. Selection criteria included a diagnosis of pars fracture with DXA Z-score values (lumbar and hip) and pretreatment serum (25[OH]D) level measurement. Twenty-four patients were included. Vitamin D was defined as sufficient when ≥ 32 ng/mL, insufficient when 20 to < 32 ng/mL, and deficient when < 20 ng/mL. BMD was interpreted from DXA Z-scores using reference intervals defined in the literature. A Z-score <-2.0 was considered low for chronological age. The mean (± SD) vitamin D level was 29.9 ng/mL ± 10.8 (range, 9-56 ng/mL). Values were ≤ 10 ng/mL in 1 patient (4%), 11-20 ng/mL in 4 patients (17%), 21-30 ng/mL in 8 patients (33%), 31-50 ng/mL in 10 patients (42%), and > 50 ng/mL in 1 patient (4%). This correlated to 3 (13%) patients with deficient vitamin D (≤ 15 ng/mL), 12 (50%) patients with insufficient levels, and 9 (38%) with sufficient levels of vitamin D. The mean Z-scores were 0.43 ± 0.93 (lumbar, range, -1.3 to 2.8) and 1.0 ± 1.11 (hip, range, -0.5 to 3.0). All scores were consistent with normal bony mineralization for age. On the basis of these data, we recommend routine vitamin D testing and do not recommend routine DXA in adolescents with lumbar stress fractures of the pars interarticularis.

  5. The cementless Bicontact stem in a prospective dual-energy X-ray absorptiometry study.

    PubMed

    Lerch, Matthias; Kurtz, Agnes; Windhagen, Henning; Bouguecha, Anas; Behrens, Bernd A; Wefstaedt, Patrick; Stukenborg-Colsman, Christina M

    2012-11-01

    The cementless Bicontact total hip arthroplasty (THA) system (AESCULAP AG, Tuttlingen, Germany) was introduced in 1986/1987 and has been in successful clinical use in an unaltered form up to today. Although good long-term results with the Bicontact stem have been published, it is questionable whether the implant provides the criteria for a state-of-the-art stem regarding proximal bone stock preservation. The purpose of the study was to monitor the periprosthetic bone mineral density (BMD) in a prospective two-year follow-up dual-energy X-ray absorptiometry (DEXA) study. After power analysis, a consecutive series of 25 patients with unilateral Bicontact stem implantation was examined clinically and underwent DEXA examinations. Scans of seven regions of interest were taken preoperatively and at one week, six months, and one and two years. One patient required stem revision due to a deep infection. The Harris Hip Score increased significantly by 44 points. The most significant bone loss was observed in the calcar region (R7) in the first six months (-19.2 %). It recovered in the following 18 months to -8.5 %. The BMD in the greater trochanter dropped significantly after six months and remained stable at this level. BMD exceeded baseline values in distal regions and even more in the lesser trochanter region after two years. We conclude that the Bicontact stem provides adequate proximal bone stock preservation. We observed some signs of stress shielding at the tip of the stem, which is inevitable to some degree in THA with cementless straight stems. However, in this prospective DEXA investigation, we showed that proximal off-loading does not occur after THA with the Bicontact system. Thus, we believe that this stem is still a state-of-the-art implant.

  6. Identification of vertebral deformities in the Polish population by morphometric X-ray absorptiometry - results of the EPOLOS study.

    PubMed

    Skowrońska-Jóźwiak, Elzbieta; Płudowski, Paweł; Karczmarewicz, Elzbieta; Lorenc, Roman; Lewiński, Andrzej

    2009-01-01

    The aim of the study was the determination of the prevalence of asymptomatic vertebral deformities in healthy persons of the Polish population, based on morphometric X-ray absorptiometry (MXA), and comparison of the results with data from literature, obtained by other techniques. The study involved 829 persons, including 520 women and 309 men, aged 18-79 years, untreated for osteoporosis before. The Th(4) to L(4) vertebrae were examined. Lateral scans of the thoracic-lumbar spine were made by an Expert-XL densitometer. Six point digitization was used to calculate the anterior (Ha), central (Hc), and posterior (Hp) height of the Th(4)-L(4) vertebral bodies. The vertebrae were defined as having prevalent deformities when at least one ratio value (Ha/Hp, Hc/Hp, Hp/Hp up, or Hp/Hp low) fell 3 SDs below or even more than the reference mean of that ratio at any vertebral level. The analysis was performed on 9629 vertebrae, of which 167 (1.75%), evaluated as deformed and considered as fractures, were observed in 113 patients (13.63 % of the examined patients). In 81 persons (74% of the patients with fractures; 9.7% of the studied population), single fractures were demonstrated, while in 28 persons, multiple deformities prevailed. Fractures occurred in 108 women (20.7% of the examined women) and 42 men (13.5% of the examined men). The highest incidence of deformities was observed in women over 55 years of age. First-degree deformities dominated. Deformities of the Th(8) and Th(6) vertebrae were most frequently observed. 1. Using MXA, it was found that in the Polish population deformities of vertebrae are common, as was demonstrated in X-ray morphometric studies in the European Vertebral Observation Study (EVOS). 2. Densitometric morphometry, as a non-invasive technique, may become a useful tool in the diagnostics of vertebral fractures.

  7. Longitudinal Changes in Anthropometry and Body Composition in University Freshmen

    ERIC Educational Resources Information Center

    Hootman, Katie C.; Guertin, Kristin A.; Cassano, Patricia A.

    2017-01-01

    Objective: We investigated predictors of weight gain in college freshmen. Participants: A longitudinal cohort study followed a representative sample of freshmen (N = 264) from 8/2011 to 6/2012. Methods: Repeated measurements of anthropometry, dual-energy X-ray absorptiometry (DXA), physical activity, and diet were collected. We investigated…

  8. TIBIAL PLATEAU PROXIMAL AND DISTAL BONE BEHAVE SIMILARLY: BOTH ARE ASSOCIATED WITH FEATURES OF KNEE OSTEOARTHRITIS

    USDA-ARS?s Scientific Manuscript database

    There is a growing imperative to understand how changes in peri-articular bone relate to pathological progression of knee osteoarthritis (KOA). Peri-articular bone density can be measured using dual x-ray absorptiometry (DXA). The medial:lateral tibial BMD ratio (M:L BMD) is associated with MRI and...

  9. Accuracy and precision of computer-assisted analysis of bone density via conventional and digital radiography in relation to dual-energy x-ray absorptiometry.

    PubMed

    Vaccaro, Calogero; Busetto, Roberto; Bernardini, Daniele; Anselmi, Carlo; Zotti, Alessandro

    2012-03-01

    To evaluate the precision and accuracy of assessing bone mineral density (BMD) by use of mean gray value (MGV) on digitalized and digital images of conventional and digital radiographs, respectively, of ex vivo bovine and equine bone specimens in relation to the gold-standard technique of dual-energy x-ray absorptiometry (DEXA). Left and right metatarsal bones from 11 beef cattle and right femurs from 2 horses. Bovine specimens were imaged by use of conventional radiography, whereas equine specimens were imaged by use of computed radiography (digital radiography). Each specimen was subsequently scanned by use of the same DEXA equipment. The BMD values resulting from each DEXA scan were paired with the MGVs obtained by use of software on the corresponding digitalized or digital radiographic image. The MGV analysis of digitalized and digital x-ray images was a precise (coefficient of variation, 0.1 and 0.09, respectively) and highly accurate method for assessing BMD, compared with DEXA (correlation coefficient, 0.910 and 0.937 for conventional and digital radiography, respectively). The high correlation between MGV and BMD indicated that MGV analysis may be a reliable alternative to DEXA in assessing radiographic bone density. This may provide a new, inexpensive, and readily available estimate of BMD.

  10. Breast Density Assessment by Dual Energy X-ray Absorptiometry in Women and Girls

    DTIC Science & Technology

    2009-07-01

    of this project among adult women and adolescent girls, who will be recruited as mothers and daughters, will be to 1. Correlate breast density...scans to their association with mammographic density; 3. Assess DXA breast density by Tanner stage of breast maturation among adolescent girls; 4...cancer risk, adolescents 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT 18. NUMBER OF PAGES 19a. NAME OF RESPONSIBLE PERSON USAMRMC

  11. Baseline Vitamin D Status is Predictive of Longitudinal Change in Tibial BMD in Knee Osteoarthritis (OA)

    USDA-ARS?s Scientific Manuscript database

    With its lack of effective treatment and high prevalence, the public health impact of OA is substantial. Peri-articular bone in OA can be evaluated with the medial:lateral tibial BMD ratio (M:L BMD) obtained from dual x-ray absorptiometry (DXA). Higher M:L BMD is associated with medial OA features...

  12. Fat to muscle ratio measurements with dual energy x-ray absorbtiometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, A.; Luo, J.; Wang, A.

    Accurate measurement of the fat-to-muscle ratio in animal model is important for obesity research. In addition, an efficient way to measure the fat to muscle ratio in animal model using dual-energy absorptiometry is presented in this paper. A radioactive source exciting x-ray fluorescence from a target material is used to provide the two x-ray energies needed. The x-rays, after transmitting through the sample, are measured with an energy-sensitive Ge detector. Phantoms and specimens were measured. The results showed that the method was sensitive to the fat to muscle ratios with good linearity. A standard deviation of a few percent inmore » the fat to muscle ratio could be observed with the x-ray dose of 0.001 mGy.« less

  13. Fat to muscle ratio measurements with dual energy x-ray absorbtiometry

    DOE PAGES

    Chen, A.; Luo, J.; Wang, A.; ...

    2015-03-14

    Accurate measurement of the fat-to-muscle ratio in animal model is important for obesity research. In addition, an efficient way to measure the fat to muscle ratio in animal model using dual-energy absorptiometry is presented in this paper. A radioactive source exciting x-ray fluorescence from a target material is used to provide the two x-ray energies needed. The x-rays, after transmitting through the sample, are measured with an energy-sensitive Ge detector. Phantoms and specimens were measured. The results showed that the method was sensitive to the fat to muscle ratios with good linearity. A standard deviation of a few percent inmore » the fat to muscle ratio could be observed with the x-ray dose of 0.001 mGy.« less

  14. Risk Factors for Osteoporosis Among Middle-Aged Women

    ERIC Educational Resources Information Center

    Turner, Lori W.; Wallace, Lorraine Silver; Perry, Blake Allen; Bleeker, Jeanne

    2004-01-01

    Objective: To investigate the risk factors for osteoporosis among a sample of middle-aged women. Methods: Adipose tissue and bone mineral density levels at the left femur, lumbar spine, and total body were assessed using dual-energy x-ray absorptiometry (DXA). Subjects (n=342) were surveyed regarding a variety of osteoporosis-related risk factors.…

  15. [Estimation of body fat by DXA and the four compartment model in Mexican youth].

    PubMed

    Ramírez, Erik; Valencia, Mauro E; Moya Camarena, Silvia Y; Alemán-Mateo, Heliodoro; Méndez, Rosa O

    2010-09-01

    The objective of this study was to validate the estimation of body fat (%BF) by DXA (Dual-Energy X-Ray AbsorciomDPX-MD) against the four compartment model (4C) of body composition in 32 Mexican pubertal girls and boys (aged 9-14 y; F=16). The mean of the difference between DXA and 4C model was -3.5 %BF (p=0.171). The limits of agreement (95% = 2 SD) were +5% to -12%BF. The precision of estimated limits of y the confidence intervals were -1.9% to -5.1%BF (P = 0.050). The concordance correlation coefficient was p = 0.85. The test of accuracy for coincidence of slop intercepts between DXA and the 4C model showed no coincidence (p < 0.05). The precision by R2 explained 83% of the variance (SEE, 4.1%). The individual accuracy assess by the total error was 5.6%. The group mean accuracy by two way analysis of variance of body fat did not show interaction between method (DXA-4C model) and separate analysis of gender and overweight. However, there was an effect of method (p = 0.043) in the presence of overweight (p < 0.001). In conclusion, the estimation of percent of body fat by DXA was not precise and accurate in a group of Mexican children. However, results do not limit the utility of DXA for the measurements of body composition and its relation with health outcomes, especially in follow up studies.

  16. Quantitative data standardization of X-ray based densitometry methods

    NASA Astrophysics Data System (ADS)

    Sergunova, K. A.; Petraikin, A. V.; Petrjajkin, F. A.; Akhmad, K. S.; Semenov, D. S.; Potrakhov, N. N.

    2018-02-01

    In the present work is proposed the design of special liquid phantom for assessing the accuracy of quantitative densitometric data. Also are represented the dependencies between the measured bone mineral density values and the given values for different X-ray based densitometry techniques. Shown linear graphs make it possible to introduce correction factors to increase the accuracy of BMD measurement by QCT, DXA and DECT methods, and to use them for standardization and comparison of measurements.

  17. Single x-ray transmission system for bone mineral density determination

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jimenez-Mendoza, Daniel; Vargas-Vazquez, Damian; Espinosa-Arbelaez, Diego G.

    2011-12-15

    Bones are the support of the body. They are composed of many inorganic compounds and other organic materials that all together can be used to determine the mineral density of the bones. The bone mineral density is a measure index that is widely used as an indicator of the health of the bone. A typical manner to evaluate the quality of the bone is a densitometry study; a dual x-ray absorptiometry system based study that has been widely used to assess the mineral density of some animals' bones. However, despite the success stories of utilizing these systems in many differentmore » applications, it is a very expensive method that requires frequent calibration processes to work properly. Moreover, its usage in small species applications (e.g., rodents) has not been quite demonstrated yet. Following this argument, it is suggested that there is a need for an instrument that would perform such a task in a more reliable and economical manner. Therefore, in this paper we explore the possibility to develop a new, affordable, and reliable single x-ray absorptiometry system. The method consists of utilizing a single x-ray source, an x-ray image sensor, and a computer platform that all together, as a whole, will allow us to calculate the mineral density of the bone. Utilizing an x-ray transmission theory modified through a version of the Lambert-Beer law equation, a law that expresses the relationship among the energy absorbed, the thickness, and the absorption coefficient of the sample at the x-rays wavelength to calculate the mineral density of the bone can be advantageous. Having determined the parameter equation that defines the ratio of the pixels in radiographies and the bone mineral density [measured in mass per unit of area (g/cm{sup 2})], we demonstrated the utility of our novel methodology by calculating the mineral density of Wistar rats' femur bones.« less

  18. Single x-ray transmission system for bone mineral density determination

    NASA Astrophysics Data System (ADS)

    Jimenez-Mendoza, Daniel; Espinosa-Arbelaez, Diego G.; Giraldo-Betancur, Astrid L.; Hernandez-Urbiola, Margarita I.; Vargas-Vazquez, Damian; Rodriguez-Garcia, Mario E.

    2011-12-01

    Bones are the support of the body. They are composed of many inorganic compounds and other organic materials that all together can be used to determine the mineral density of the bones. The bone mineral density is a measure index that is widely used as an indicator of the health of the bone. A typical manner to evaluate the quality of the bone is a densitometry study; a dual x-ray absorptiometry system based study that has been widely used to assess the mineral density of some animals' bones. However, despite the success stories of utilizing these systems in many different applications, it is a very expensive method that requires frequent calibration processes to work properly. Moreover, its usage in small species applications (e.g., rodents) has not been quite demonstrated yet. Following this argument, it is suggested that there is a need for an instrument that would perform such a task in a more reliable and economical manner. Therefore, in this paper we explore the possibility to develop a new, affordable, and reliable single x-ray absorptiometry system. The method consists of utilizing a single x-ray source, an x-ray image sensor, and a computer platform that all together, as a whole, will allow us to calculate the mineral density of the bone. Utilizing an x-ray transmission theory modified through a version of the Lambert-Beer law equation, a law that expresses the relationship among the energy absorbed, the thickness, and the absorption coefficient of the sample at the x-rays wavelength to calculate the mineral density of the bone can be advantageous. Having determined the parameter equation that defines the ratio of the pixels in radiographies and the bone mineral density [measured in mass per unit of area (g/cm2)], we demonstrated the utility of our novel methodology by calculating the mineral density of Wistar rats' femur bones.

  19. Does Quantitative Tibial Ultrasound Predict Low Bone Mineral Density Defined by Dual Energy X-Ray Absorptiometry?

    PubMed Central

    Birtane, Murat; Ekuklu, Galip; Cermik, Fikret; Tuna, Filiz; Kokino, Siranus

    2008-01-01

    Purpose Efforts for the early detection of bone loss and subsequent fracture risk by quantitative ultrasound (QUS), which is a non-invasive, radiation free, and cheaper method, seem rational to reduce the management costs. We aimed in this study to assess the probable correlation of speed of sound (SOS) values obtained by QUS with bone mineral density (BMD) as measured by the gold standard method, dual energy X-ray absorptiometry (DEXA), and to investigate the diagnostic value of QUS to define low BMD. Materials and Methods One hundred twenty-two postmenopausal women having prior standard DEXA measurements were included in the study. Spine and proximal femur (neck, trochanter and Ward's triangle) BMD were assessed in a standard protocol by DEXA. The middle point of the right tibia was chosen for SOS measurement by tibial QUS. Results The SOS values were observed to be significantly higher in the normal BMD (t score > - 1) group at all measurement sites except for the lumbar region, when compared with the low BMD group (t score < - 1). SOS was negatively correlated with age (r = - 0.66) and month since menopause (r = - 0.57). The sensitivity, specificity, and positive and negative predictive values for QUS t score to diagnose low BMD did not seem to be satisfactory at either of the measurement sites. Conclusion Tibial SOS was correlated weakly with BMD values of femur and lumbar spine as measured by DEXA and its diagnostic value did not seem to be high for discriminating between normal and low BMD, at these sites. PMID:18581594

  20. Fat and Lean Masses in Youths with Down Syndrome: Gender Differences

    ERIC Educational Resources Information Center

    Gonzalez-Aguero, Alejandro; Ara, Ignacio; Moreno, Luis A.; Vicente-Rodriguez, German; Casajus, Jose A.

    2011-01-01

    The present study aimed at comparing fat and lean masses between children and adolescents with and without Down syndrome (DS) and evaluating the presence of sexual dimorphism. Total and regional fat and lean masses were assessed by dual energy X-ray absorptiometry (DXA) and the percentage of body fat (%BF) by air-displacement plethysmography (ADP)…

  1. Standards and measurements for assessing bone health-workshop report co-sponsored by the International Society for Clinical Densitometry (ISCD) and the National Institute of Standards and Technology (NIST).

    PubMed

    Bennett, Herbert S; Dienstfrey, Andrew; Hudson, Lawrence T; Oreskovic, Tammy; Fuerst, Thomas; Shepherd, John

    2006-01-01

    This article reports and discusses the results of the recent ISCD-NIST Workshop on Standards and Measurements for Assessing Bone Health. The purpose of the workshop was to assess the status of efforts to standardize and compare results from dual-energy X-ray absorptiometry (DXA) scans, and then to identify and prioritize ongoing measurement and standards needs.

  2. Body Fat and Breast Cancer Risk in Postmenopausal Women: A Longitudinal Study

    PubMed Central

    Rohan, Thomas E.; Heo, Moonseong; Choi, Lydia; Freudenheim, Jo L.; Kamensky, Victor; Ochs-Balcom, Heather M.; Thomson, Cynthia A.; Vitolins, Mara Z.; Wassertheil-Smoller, Sylvia; Kabat, Geoffrey C.

    2013-01-01

    Associations between anthropometric indices of obesity and breast cancer risk may fail to capture the true relationship between excess body fat and risk. We used dual-energy-X-ray-absorptiometry- (DXA-) derived measures of body fat obtained in the Women's Health Initiative to examine the association between body fat and breast cancer risk; we compared these risk estimates with those for conventional anthropometric measurements. The study included 10,960 postmenopausal women aged 50–79 years at recruitment, with baseline DXA measurements and no history of breast cancer. During followup (median: 12.9 years), 503 incident breast cancer cases were diagnosed. Hazard ratios (HR) and 95% confidence intervals (CI) were estimated using Cox proportional hazards models. All baseline DXA-derived body fat measures showed strong positive associations with breast cancer risk. The multivariable-adjusted HR for the uppermost quintile level (versus lowest) ranged from 1.53 (95% CI 1.14–2.07) for fat mass of the right leg to 2.05 (1.50–2.79) for fat mass of the trunk. Anthropometric indices (categorized by quintiles) of obesity (BMI (1.97, 1.45–2.68), waist circumference (1.97, 1.46–2.65), and waist : hip ratio (1.91, 1.41–2.58)) were all strongly, positively associated with risk and did not differ from DXA-derived measures in prediction of risk. PMID:23690776

  3. Hard X-ray imaging from Explorer

    NASA Technical Reports Server (NTRS)

    Grindlay, J. E.; Murray, S. S.

    1981-01-01

    Coded aperture X-ray detectors were applied to obtain large increases in sensitivity as well as angular resolution. A hard X-ray coded aperture detector concept is described which enables very high sensitivity studies persistent hard X-ray sources and gamma ray bursts. Coded aperture imaging is employed so that approx. 2 min source locations can be derived within a 3 deg field of view. Gamma bursts were located initially to within approx. 2 deg and X-ray/hard X-ray spectra and timing, as well as precise locations, derived for possible burst afterglow emission. It is suggested that hard X-ray imaging should be conducted from an Explorer mission where long exposure times are possible.

  4. A systematic quality assurance study in bone densitometry devices

    NASA Astrophysics Data System (ADS)

    Tuncman, Duygu; Kovan, Hatice; Kovan, Bilal; Demir, Bayram; Turkmen, Cuneyt

    2015-07-01

    Osteoporosis is the most common metabolic bone disease and can result in devastating physical, psychosocial, and economic consequences. It occurs in women after menopause and affects most elderly. Dual-energy x-ray absorptiometry (DXA) is currently the most widely used method for the measurement of areal Bone Mineral Density (BMD) (g/cm2) .DXA is based on the variable absorption of X-ray by the different body components and uses high and low energy X-ray photons. There are two important values in the assessment of the DXA. These values are T-score and Z-score. The T-score is calculated by taking the difference between a patient's measured BMD with the mean BMD of the young normal population, matched for gender and ethnicity, and then by dividing the difference with the standard deviation (SD) of the BMD of the young normal population. T-score and also Z-score are directly depends on the Bone Mineral Density (BMD). BMD measurements should be made periodically in a patient life. But mostly, it is not possible with the same device. Therefore, in this study, for the quality assurance of bone densitometry devices, we evaluated the BMD results measured in the different Bone Densitometry (DXA) devices using a spine phantom.

  5. Assessment of Body Composition Using Dual Energy X-Ray Absorptiometry in Patients with Liver Cirrhosis: Comparison with Anthropometry

    PubMed Central

    Jeong, Seong Han; Lee, Jeong A; Kim, Jin A; Lee, Mun Woo; Chae, Hee Bok; Choi, Won Jun; Shin, Hyoung Shik; Lee, Ki Hyeong; Youn, Sei Jin; Koong, Sung Soo; Park, Seon Mee

    1999-01-01

    Objectives The aim of this study was to evaluate changes of body composition in cirrhotic patients. Dual energy x-ray absorptiometry (DEXA) and anthropometry were used, and the values obtained were compared. Methods Mid-arm fat and muscle areas were calculated by anthropometry in 66 cirrhotic patients and 94 healthy controls. In 37 of the cirrhotic patients and 39 of the controls, fat mass, lean soft tissue mass and bone mineral contents were measured with DEXA. Results The number of cirrhotic patients with measured values below the fifth percentile of normal controls was 21 (31.8%) by mid-arm fat area, six (9.1%) by mid-arm muscle area, 15 (40.5%) by fat mass and 0 (0%) by lean soft tissue mass. The fat mass in cirrhotic patients was less than in controls, whereas lean soft tissue mass and bone mineral content were not different. Fat depletion was severe in Child-class C patients and with severe ascites. Mid-arm fat area and fat mass showed close correlation (r = 0.85, p<0.01), but mid-arm muscle area and lean soft tissue mass showed poor correlation (r = 0.32, p<0.05). Conclusion Cirrhotic patients showed lower fat component, with preserved lean soft tissue mass and bone mineral content. In clinical practice, the measurement of mid-arm fat area was useful for the assessment of fat mass. PMID:10461427

  6. The role of carboxy-terminal cross-linking telopeptide of type I collagen, dual x-ray absorptiometry bone strain and Romberg test in a new osteoporotic fracture risk evaluation: A proposal from an observational study.

    PubMed

    Ulivieri, Fabio M; Piodi, Luca P; Grossi, Enzo; Rinaudo, Luca; Messina, Carmelo; Tassi, Anna P; Filopanti, Marcello; Tirelli, Anna; Sardanelli, Francesco

    2018-01-01

    The consolidated way of diagnosing and treating osteoporosis in order to prevent fragility fractures has recently been questioned by some papers, which complained of overdiagnosis and consequent overtreatment of this pathology with underestimating other causes of the fragility fractures, like falls. A new clinical approach is proposed for identifying the subgroup of patients prone to fragility fractures. This retrospective observational study was conducted from January to June 2015 at the Nuclear Medicine-Bone Metabolic Unit of the of the Fondazione IRCCS Ca' Granda, Milan, Italy. An Italian population of 125 consecutive postmenopausal women was investigated for bone quantity and bone quality. Patients with neurological diseases regarding balance and vestibular dysfunction, sarcopenia, past or current history of diseases and use of drugs known to affect bone metabolism were excluded. Dual X-ray absorptiometry was used to assess bone quantity (bone mineral density) and bone quality (trabecular bone score and bone strain). Biochemical markers of bone turnover (type I collagen carboxy-terminal telopeptide, alkaline phosphatase, vitamin D) have been measured. Morphometric fractures have been searched by spine radiography. Balance was evaluated by the Romberg test. The data were evaluated with the neural network analysis using the Auto Contractive Map algorithm. The resulting semantic map shows the Minimal Spanning Tree and the Maximally Regular Graph of the interrelations between bone status parameters, balance conditions and fractures of the studied population. A low fracture risk seems to be related to a low carboxy-terminal cross-linking telopeptide of type I collagen level, whereas a positive Romberg test, together with compromised bone trabecular microarchitecture DXA parameters, appears to be strictly connected with fragility fractures. A simple assessment of the risk of fragility fracture is proposed in order to identify those frail patients at risk for

  7. The prediction of lean body mass and fat mass from arm anthropometry at diagnosis in children with cancer.

    PubMed

    Webber, Colin; Halton, Jacqueline; Walker, Scott; Young, Andrea; Barr, Ronald D

    2013-10-01

    Maintenance of adequate nutrition is important in the care of children with cancer. In clinical practice, determination of nutritional status can be accomplished with measurement of body composition by dual-energy x-ray absorptiometry (DXA). However, DXA is seldom available in low-income countries where most children with cancer live. This study sought to provide predictive equations for lean body mass and fat mass, measured by DXA, on the basis of simple arm anthropometry providing measures of mid-upper arm circumference and triceps skin-fold thickness in a population (N=99) of children diagnosed with cancer. Such equations were derived successfully with the inclusion of absolute body weight, the body weight Z-score, and the predicted whole-body bone mineral content on the basis of age and sex. Attempted validation in a small sample (N=7) of children who completed therapy for acute lymphoblastic leukemia revealed disparities reflective of the prevalence of obesity in such survivors. Further validation must be undertaken in large samples of children with a variety of malignant diseases to assess the robustness of the equations predictive of body composition.

  8. A DXA Whole Body Composition Cross-Calibration Experience: Evaluation With Humans, Spine, and Whole Body Phantoms.

    PubMed

    Krueger, Diane; Libber, Jessie; Sanfilippo, Jennifer; Yu, Hui Jing; Horvath, Blaine; Miller, Colin G; Binkley, Neil

    2016-01-01

    New densitometer installation requires cross-calibration for accurate longitudinal assessment. When replacing a unit with the same model, the International Society for Clinical Densitometry recommends cross-calibrating by scanning phantoms 10 times on each instrument and states that spine bone mineral density (BMD) should be within 1%, whereas total body lean, fat, and %fat mass should be within 2% of the prior instrument. However, there is limited validation that these recommendations provide adequate total body cross-calibration. Here, we report a total body cross-calibration experience with phantoms and humans. Cross-calibration between an existing and new Lunar iDXA was performed using 3 encapsulated spine phantoms (GE [GE Lunar, Madison, WI], BioClinica [BioClinica Inc, Princeton, NJ], and Hologic [Hologic Inc, Bedford, MA]), 1 total body composition phantom (BioClinica), and 30 human volunteers. Thirty scans of each phantom and a total body scan of human volunteers were obtained on each instrument. All spine phantom BMD means were similar (within 1%; <-0.010 g/cm2 bias) between the existing and new dual-energy X-ray absorptiometry unit. The BioClinica body composition phantom (BBCP) BMD and bone mineral content (BMC) values were within 2% with biases of 0.005 g/cm2 and -3.4 g. However, lean and fat mass and %fat differed by 4.6%-7.7% with biases of +463 g, -496 g, and -2.8%, respectively. In vivo comparison supported BBCP data; BMD and BMC were within ∼2%, but lean and fat mass and %fat differed from 1.6% to 4.9% with biases of +833 g, -860 g, and -1.1%. As all body composition comparisons exceeded the recommended 2%, the new densitometer was recalibrated. After recalibration, in vivo bias was lower (<0.05%) for lean and fat; -23 and -5 g, respectively. Similarly, BBCP lean and fat agreement improved. In conclusion, the BBCP behaves similarly, but not identical, to human in vivo measurements for densitometer cross-calibration. Spine phantoms, despite good

  9. Effects of Whole Body Vibration Training on Body Composition in Adolescents with Down Syndrome

    ERIC Educational Resources Information Center

    Gonzalez-Aguero, Alejandro; Matute-Llorente, Angel; Gomez-Cabello, Alba; Casajus, Jose A.; Vicente-Rodriguez, German

    2013-01-01

    The present study aimed to determine the effect of 20 weeks of whole body vibration (WBV) on the body composition of adolescents with Down syndrome (DS). Thirty adolescent with DS were divided into two groups: control and WBV. Whole body, upper and lower limbs body fat and lean body mass were measured with dual energy X-ray absorptiometry (DXA)…

  10. Skeletal Recovery Following Long-Duration Spaceflight Missions as Determined by Preflight and Postflight DXA Scans of 45 Crew Members

    NASA Technical Reports Server (NTRS)

    Sibonga, J. D.; Evans, H. J.; Sung, H. G.; Spector, E. R.; Lang, T. F.; Oganov, V. S.; Bakulin, A. V.; Shackelford, L. C.; LeBlanc, A. D.

    2006-01-01

    Introduction: The loss of bone mineral in astronauts during spaceflight has been investigated throughout the more than 40 years of bone research in space. Consequently, it is a medical requirement at NASA that changes in bone mass be monitored in crew members by measurements of bone mineral density (BMD) with dual-energy x-ray absorptiometry (DXA). This report is the first to evaluate medical data to address the recovery of bone mineral that is lost during spaceflight. Methods: DXA scans are performed before and after flight in astronauts who serve on long-duration missions (4-6 months) to ensure that medical standards for flight certification are met, to evaluate the effects of spaceflight and to monitor the restoration to preflight BMD status after return to Earth. Through cooperative agreements with the Russian Space Agency, the Bone and Mineral Lab at NASA Johnson Space Center (Houston, TX), also had access to BMD data from cosmonauts who had flown on long-duration missions yielding data from a total of 45 individual crew members. Changes in BMD (between 56 different sets of pre- and postflight measurements) were plotted as a function of time (days after landing); plotted data were fitted to an exponential mathematical model that determined i) BMD change at day 0 after landing and ii) the number of days after which 50% of the lost bone was recovered ("Recovery Half-Life"). These fits were performed for BMD of the lumbar spine, trochanter, pelvis, femoral neck and calcaneus. Results: In sum, averaged losses of bone mineral after spaceflight ranged between 2-9% for sites in the axial and appendicular skeleton. The fitted postflight BMD values predicted a 50% recovery of bone loss for all sites within 9 months.

  11. Utilization of BIA-Derived Bone Mineral Estimates Exerts Minimal Impact on Body Fat Estimates via Multicompartment Models in Physically Active Adults.

    PubMed

    Nickerson, Brett S; Tinsley, Grant M

    2018-03-21

    The purpose of this study was to compare body fat estimates and fat-free mass (FFM) characteristics produced by multicompartment models when utilizing either dual energy X-ray absorptiometry (DXA) or single-frequency bioelectrical impedance analysis (SF-BIA) for bone mineral content (BMC) in a sample of physically active adults. Body fat percentage (BF%) was estimated with 5-compartment (5C), 4-compartment (4C), 3-compartment (3C), and 2-compartment (2C) models, and DXA. The 5C-Wang with DXA for BMC (i.e., 5C-Wang DXA ) was the criterion. 5C-Wang using SF-BIA for BMC (i.e., 5C-Wang BIA ), 4C-Wang DXA (DXA for BMC), 4C-Wang BIA (BIA for BMC), and 3C-Siri all produced values similar to 5C-Wang DXA (r > 0.99; total error [TE] < 0.83%; standard error of estimate < 0.67%; 95% limits of agreement [LOAs] < ±1.35%). The 2C models (2C-Pace, 2C-Siri, and 2C-Brozek) and DXA each produced similar standard error of estimate and 95% LOAs (2.13%-3.12% and ±4.15%-6.14%, respectively). Furthermore, 3C-Lohman DXA (underwater weighing for body volume and DXA for BMC) and 3C-Lohman BIA (underwater weighing for body volume and SF-BIA for BMC) produced the largest 95% LOAs (±5.94%-8.63%). The FFM characteristics (i.e., FFM density, water/FFM, mineral/FFM, and protein/FFM) for 5C-Wang DXA and 5C-Wang BIA were each compared with the "reference body" cadavers of Brozek et al. 5C-Wang BIA FFM density differed significantly from the "reference body" in women (1.103 ± 0.007 g/cm 3 ; p < 0.001), but no differences were observed for 5C-Wang DXA or either 5C model in men. Moreover, water/FFM and mineral/FFM were significantly lower in men and women when comparing 5C-Wang DXA and 5C-Wang BIA with the "reference body," whereas protein/FFM was significantly higher (all p ≤ 0.001). 3C-Lohman BIA and 3C-Lohman DXA produced error similar to 2C models and DXA and are therefore not recommended multicompartment models. Although more advanced multicompartment models (e

  12. Dual-energy x-ray absorptiometry to measure the effects of a thirteen-week moderate to vigorous aquatic exercise and nutritional education intervention on percent body fat in adults with intellectual disabilities from group home settings.

    PubMed

    Casey, Amanda; Boyd, Colin; Mackenzie, Sasho; Rasmussen, Roy

    2012-05-01

    People with intellectual disability are more likely to be obese and extremely obese than people without intellectual disability with rates remaining elevated among adults, women and individuals living in community settings. Dual-energy X-ray absorptiometry measured the effects of a 13-week aquatic exercise and nutrition intervention on percent body fat in eight adults with intellectual disabilities (aged 41.0 ± 13.7 yrs) of varying fat levels (15%-39%) from two group homes. A moderate to vigorous aquatic exercise program lasted for the duration of 13 weeks with three, one-hour sessions held at a 25m pool each week. Nutritional assistants educated participants as to the importance of food choice and portion size. A two-tailed Wilcoxon matched-pairs signed-ranks test determined the impact of the combined intervention on body fat percentage and BMI at pre and post test. Median body fat percentage (0.8 %) and BMI (0.3 kg/m(2)) decreased following the exercise intervention, but neither were statistically significant, p = .11 and p = .55, respectively. The combined intervention was ineffective at reducing percent body fat in adults with intellectual disability according to dual-energy X-ray absorptiometry. These results are in agreement with findings from exercise alone interventions and suggest that more stringent nutritional guidelines are needed for this population and especially for individuals living in group home settings. The study did show that adults with intellectual disability may participate in moderate to vigorous physical activity when given the opportunity.

  13. Utilization of DXA Bone Mineral Densitometry in Ontario: An Evidence-Based Analysis.

    PubMed

    2006-01-01

    Systematic reviews and analyses of administrative data were performed to determine the appropriate use of bone mineral density (BMD) assessments using dual energy x-ray absorptiometry (DXA), and the associated trends in wrist and hip fractures in Ontario. DUAL ENERGY X-RAY ABSORPTIOMETRY BONE MINERAL DENSITY ASSESSMENT: Dual energy x-ray absorptiometry bone densitometers measure bone density based on differential absorption of 2 x-ray beams by bone and soft tissues. It is the gold standard for detecting and diagnosing osteoporosis, a systemic disease characterized by low bone density and altered bone structure, resulting in low bone strength and increased risk of fractures. The test is fast (approximately 10 minutes) and accurate (exceeds 90% at the hip), with low radiation (1/3 to 1/5 of that from a chest x-ray). DXA densitometers are licensed as Class 3 medical devices in Canada. The World Health Organization has established criteria for osteoporosis and osteopenia based on DXA BMD measurements: osteoporosis is defined as a BMD that is >2.5 standard deviations below the mean BMD for normal young adults (i.e. T-score <-2.5), while osteopenia is defined as BMD that is more than 1 standard deviation but less than 2.5 standard deviation below the mean for normal young adults (i.e. T-score< -1 & ≥-2.5). DXA densitometry is presently an insured health service in Ontario.   BURDEN OF DISEASE: The Canadian Multicenter Osteoporosis Study (CaMos) found that 16% of Canadian women and 6.6% of Canadian men have osteoporosis based on the WHO criteria, with prevalence increasing with age. Osteopenia was found in 49.6% of Canadian women and 39% of Canadian men. In Ontario, it is estimated that nearly 530,000 Ontarians have some degrees of osteoporosis. Osteoporosis-related fragility fractures occur most often in the wrist, femur and pelvis. These fractures, particularly those in the hip, are associated with increased mortality, and decreased functional capacity and quality of

  14. The Relationship Between Fractures and DXA Measures of BMD in the Distal Femur of Children and Adolescents With Cerebral Palsy or Muscular Dystrophy

    PubMed Central

    Henderson, Richard C; Berglund, Lisa M; May, Ryan; Zemel, Babette S; Grossberg, Richard I; Johnson, Julie; Plotkin, Horacio; Stevenson, Richard D; Szalay, Elizabeth; Wong, Brenda; Kecskemethy, Heidi H; Harcke, H Theodore

    2010-01-01

    Children with limited or no ability to ambulate frequently sustain fragility fractures. Joint contractures, scoliosis, hip dysplasia, and metallic implants often prevent reliable measures of bone mineral density (BMD) in the proximal femur and lumbar spine, where BMD is commonly measured. Further, the relevance of lumbar spine BMD to fracture risk in this population is questionable. In an effort to obtain bone density measures that are both technically feasible and clinically relevant, a technique was developed involving dual-energy X-ray absorptiometry (DXA) measures of the distal femur projected in the lateral plane. The purpose of this study is to test the hypothesis that these new measures of BMD correlate with fractures in children with limited or no ability to ambulate. The relationship between distal femur BMD Z-scores and fracture history was assessed in a cross-sectional study of 619 children aged 6 to 18 years with muscular dystrophy or moderate to severe cerebral palsy compiled from eight centers. There was a strong correlation between fracture history and BMD Z-scores in the distal femur; 35% to 42% of those with BMD Z-scores less than −5 had fractured compared with 13% to 15% of those with BMD Z-scores greater than −1. Risk ratios were 1.06 to 1.15 (95% confidence interval 1.04–1.22), meaning a 6% to 15% increased risk of fracture with each 1.0 decrease in BMD Z-score. In clinical practice, DXA measure of BMD in the distal femur is the technique of choice for the assessment of children with impaired mobility. © 2010 American Society for Bone and Mineral Research PMID:19821773

  15. Bone Density in Peripubertal Boys with Autism Spectrum Disorders

    ERIC Educational Resources Information Center

    Neumeyer, Ann M.; Gates, Amy; Ferrone, Christine; Lee, Hang; Misra, Madhusmita

    2013-01-01

    We determined whether bone mineral density (BMD) is lower in boys with autism spectrum disorders (ASD) than controls, and also assessed variables that may affect BMD in ASD. BMD was measured using dual energy X-ray absorptiometry (DXA) in 18 boys with ASD and 19 controls 8-14 years old. Boys with ASD had lower BMD Z-scores at the spine, hip and…

  16. Cost-effectiveness of osteoporosis screening strategies for hip fracture prevention in older Chinese people: a decision tree modeling study in the Mr. OS and Ms. OS cohort in Hong Kong.

    PubMed

    Su, Y; Lai, F T T; Yip, B H K; Leung, J C S; Kwok, T C Y

    2018-05-17

    Despite the high costs of hip fracture, many governments provide limited support for osteoporosis screening. We demonstrated that osteoporosis screening by dual-energy X-ray absorptiometry (DXA) with or without pre-screening by Fracture Risk Assessment Tool (FRAX) or calcaneal ultrasound are more cost-effective than no screening in Chinese people aged 65 or over in Hong Kong. To examine the cost-effective potential osteoporosis screening strategies for hip fracture prevention in Hong Kong. Decision tree models were constructed to evaluate the cost per quality-adjusted life years (QALYs) of the different osteoporosis screening strategies followed by subsequent 5-year treatment with alendronate compared to no screening (but treat if a hip fracture occurs). The multiple osteoporosis screening strategies were composed of alternative tests and initiation age groups were evaluated with a 10-year horizon, and treatment were assigned if central dual-energy X-ray absorptiometry (DXA) T-score (at either the hip or spine) is - 2.5 or less. Strategies included DXA for all people and pre-screening with the Fracture Risk Assessment Tool (FRAX) at specific thresholds or by calcaneal quantitative ultrasonography (QUS) before taking DXA examination. All the model inputs were based on the Mr. OS and Ms. OS Hong Kong cohort; data are obtained from the Social Welfare Department or the published literature. All of the screening strategies, including the universal screening with DXA and the pre-screening with FRAX or QUS before DXA, were consistently more cost-effective than no screening for people aged 65 years old or over. One-way sensitivity analysis with a more optimistic assumption on treatment adherence or inclusion of other major osteoporotic fractures did not change the results materially. Probabilistic sensitivity analyses showed a dominant role of pre-screening with FRAX followed by subsequent osteoporosis drug treatment in people aged 70 years old or over in Hong Kong

  17. X-ray shielding behaviour of kaolin derived mullite-barites ceramic

    NASA Astrophysics Data System (ADS)

    Ripin, A.; Mohamed, F.; Choo, T. F.; Yusof, M. R.; Hashim, S.; Ghoshal, S. K.

    2018-03-01

    Mullite-barite ceramic (MBC) is an emergent material for effective shielding of redundant ionizing radiation exposure. The composition dependent mechanical, thermal, and microstructure properties of MBC that makes MBC a high performing novel radiation shielding candidate remained unexplored. This paper examines the possibility of exploiting Malaysian kaolin (AKIM-35) and barite (BaSO4) derived ceramic (MBC) system for X-ray shielding operation. Using conventional pressing and sintering method six ceramic samples are prepared by mixing AKIM-35 with barite at varying contents (0, 10, 20, 30, 40 and 50 wt%). Synthesized pressed mixtures are calcined at 400 °C for 30 min and then sintered to 1300 °C for 120 min at a heating rate of 10 °C/min. Sintered samples are characterized via X-ray Diffraction (XRD), Field Emission Scanning Electron Microscope (FESEM), lead equivalent (LE), uniformity and dose reduction analyses. XRD pattern of prepared ceramics revealed the presence of monoclinic barium alumino-silicate (BAS) and orthorhombic mullite as major shielding phases together with other minor phase of barite and hexagonal quartz (SiO2) structures. Furthermore, FESEM images of ceramics (between 0 and 30 wt%) displayed the existence of compacted monoclinic plate of BAS and acicular mullite morphology (ceramics at 40 and 50 wt%). Radiation tests displayed the capacity of ceramics (at 0 and 10 wt%) to shield the X-ray radiation emanated at tube potential range of 50-120 kV. The highest radiation attenuation is ascertained at 70 kV where the dose is reduced remarkably between 99.11% and 97.42%. Ceramics at 0 and 10 wt% demonstrated the highest lead (Pb) equivalent thickness (LE) of 0.44 mm and 0.34 mm, respectively. It is established that such MBC may contribute towards the development of shielding material against ionizing radiation in diagnostic radiology (X-ray) dose range.

  18. The derived population of luminous supersoft X-ray sources

    NASA Technical Reports Server (NTRS)

    Di Stefano, R.STEFANO; Rappaport, S.

    1994-01-01

    The existence of a new class of astrophysical object, luminous supersoft X-ray sources, has been established through ROSAT satellite observations and analysis during the past approximately 3 yr. Because most of the radiation emitted by supersoft sources spans a range of wavelengths readily absorbed by interstellar gas, a substantial fraction of these sources may not be detectable with present satellite instrumentation. It is therefore important to derive a reliable estimate of the underlying population, based on the approximately 30 sources that have been observed to date. The work reported here combines the observational results with a theoretical analysis, to obtain an estimate of the total number of sources likely to be present in M31, the Magellanic Clouds, and in our own Galaxy. We find that in M31, where approximately 15 supersoft sources have been identified and roughly an equal number of sources are being investigated as supersoft candidates, there are likely to be approximately 2500 active supersoft sources at the present time. In our own Galaxy, where about four supersoft sources have been detected in the Galactic plane, there are likely to be approximately 1000 active sources. Similarly, with about six and about four (nonforeground) sources observed in the Large (LMC) and Small Magellanic Clouds (SMC), respectively, there should be approximately 30 supersoft sources in the LMC, and approximately 20 in the SMC. The likely uncertainties in the numbers quoted above, and the properties of observable sources relative to those of the total underlying population, are also derived in detail. These results can be scaled to estimate the numbers of supersoft sources likely to be present in other galaxies. The results reported here on the underlying population of supersoft X-ray sources are in good agreement with the results of a prior population synthesis study of the white dwarf accretor model for luminous supersoft X-ray sources. It should be emphasized, however

  19. Magnetic resonance imaging and dual energy X-ray absorptiometry of the lumbar spine in professional wrestlers and untrained men.

    PubMed

    Hu, M; Sheng, J; Kang, Z; Zou, L; Guo, J; Sun, P

    2014-08-01

    The aim of this study was to examine the relation between bone marrow adipose tissue (BMAT) and bone mineral density (BMD) of lumbar spine in male professional wrestlers and healthy untrained men. A total of 14 wrestlers (22.9±3.4 years) and 11 controls (24.4±1.6 years) were studied cross-sectionally. Body composition and BMD were measured by dual-energy X-ray absorptiometry. Magnetic resonance imaging of the lumbar spine was examined in a sagittal T1-weighted (T1-w) spin-echo (SE) sequence. The averaged bone marrow signal intensity (SI) of L2-L4 was related to the signal of an adjacent nondegenerative disk. Mean SI of T1-w SE in wrestlers was lower than controls (P=0.001), indicating L2-L4 BMAT in wrestlers was lower compared to controls. L2-L4 BMD in wrestlers was higher than controls (P<0.001). In the total subject population, L2-L4 BMD was inversely correlated with mean SI of T1-w SE (r=-0.62, P=0.001). This association remained strong after adjusting for body mass and whole lean mass, but became weaker after adjusting for whole body or trunk fat percentage. The inverse relationship between BMAT and BMD was confirmed in this relatively small subject sample with narrow age range, which implies that exercise training is an important determinant of this association.

  20. X-ray and gamma ray astronomy detectors

    NASA Technical Reports Server (NTRS)

    Decher, Rudolf; Ramsey, Brian D.; Austin, Robert

    1994-01-01

    X-ray and gamma ray astronomy was made possible by the advent of space flight. Discovery and early observations of celestial x-rays and gamma rays, dating back almost 40 years, were first done with high altitude rockets, followed by Earth-orbiting satellites> once it became possible to carry detectors above the Earth's atmosphere, a new view of the universe in the high-energy part of the electromagnetic spectrum evolved. Many of the detector concepts used for x-ray and gamma ray astronomy were derived from radiation measuring instruments used in atomic physics, nuclear physics, and other fields. However, these instruments, when used in x-ray and gamma ray astronomy, have to meet unique and demanding requirements related to their operation in space and the need to detect and measure extremely weak radiation fluxes from celestial x-ray and gamma ray sources. Their design for x-ray and gamma ray astronomy has, therefore, become a rather specialized and rapidly advancing field in which improved sensitivity, higher energy and spatial resolution, wider spectral coverage, and enhanced imaging capabilities are all sought. This text is intended as an introduction to x-ray and gamma ray astronomy instruments. It provides an overview of detector design and technology and is aimed at scientists, engineers, and technical personnel and managers associated with this field. The discussion is limited to basic principles and design concepts and provides examples of applications in past, present, and future space flight missions.

  1. The Cambridge-Cambridge X-ray Serendipity Survey: I X-ray luminous galaxies

    NASA Technical Reports Server (NTRS)

    Boyle, B. J.; Mcmahon, R. G.; Wilkes, B. J.; Elvis, M.

    1994-01-01

    We report on the first results obtained from a new optical identification program of 123 faint X-ray sources with S(0.5-2 keV) greater than 2 x 10(exp -14) erg/s/sq cm serendipitously detected in ROSAT PSPC pointed observations. We have spectroscopically identified the optical counterparts to more than 100 sources in this survey. Although the majority of the sample (68 objects) are QSO's, we have also identified 12 narrow emission line galaxies which have extreme X-ray luminosities (10(exp 42) less than L(sub X) less than 10(exp 43.5) erg/s). Subsequent spectroscopy reveals them to be a mixture of star-burst galaxies and Seyfert 2 galaxies in approximately equal numbers. Combined with potentially similar objects identified in the Einstein Extended Medium Sensitivity Survey, these X-ray luminous galaxies exhibit a rate of cosmological evolution, L(sub X) varies as (1 + z)(exp 2.5 +/- 1.0), consistent with that derived for X-ray QSO's. This evolution, coupled with the steep slope determined for the faint end of the X-ray luminosity function (Phi(L(sub X)) varies as L(sub X)(exp -1.9)), implies that such objects could comprise 15-35% of the soft (1-2 keV) X-ray background.

  2. A Normal Reference of Bone Mineral Density (BMD) Measured by Dual Energy X-Ray Absorptiometry in Healthy Thai Children and Adolescents Aged 5–18 Years: A New Reference for Southeast Asian Populations

    PubMed Central

    Nakavachara, Pairunyar; Pooliam, Julaporn; Weerakulwattana, Linda; Kiattisakthavee, Pornpimol; Chaichanwattanakul, Katharee; Manorompatarasarn, Racahnee; Chokephaibulkit, Kulkanya; Viprakasit, Vip

    2014-01-01

    Ethnic-specific normative data of bone mineral density (BMD) is essential for the accurate interpretation of BMD measurement. There have been previous reports of normative BMD data for Caucasian and Asian children including Japanese, Chinese, Korean and Indian. However, the normative BMD data for Southeast Asian including Thai children and adolescents are not currently available. The goals of our study were 1) to establish normative data of BMD, bone mineral content (BMC), bone area (BA) and lean body mass (LBM) for healthy Thai children and adolescents; aged 5–18 years measured by dual energy X-ray absorptiometry (DXA, Lunar Prodigy) and 2) to evaluate the relationships between BMD vs. age, sex, puberty, weight, height, calcium intake and the age of menarche in our population. Gender and age-specific BMD (L2-4; LS and total body; TB), BMADLS (apparent BMD of the lumbar spine), BMC (L2-4 and total body), BA (L2-4 and total body) and LBM were evaluated in 367 children (174 boys and 193 girls). All parameters increased progressively with age. A rapid increase in BMD, BMC and BMADLS was observed at earlier ages in girls. Gender and Tanner stage-specific BMD normative data were also generated. The dynamic changes of BMD values from childhood to early and late puberty of Thai children appeared to be consistent with those of Caucasian and Asian populations. Using a multiple-regression, weight and Tanner stage significantly affected BMDLS, BMDTB and BMADLS in both genders. Only in girls, height was found to have significant influence on BMDTB and BMADLS. The positive correlation between BMD and several demographic parameters, except the calcium intake, was observed. In summary, we established a normal BMD reference for Thai children and adolescents and this will be of useful for clinicians and researchers to appropriately assess BMD in Thais and other Southeast Asian children. PMID:24847716

  3. Texture analysis of clinical radiographs using radon transform on a local scale for differentiation between post-menopausal women with and without hip fracture

    NASA Astrophysics Data System (ADS)

    Boehm, Holger F.; Körner, Markus; Baumert, Bernhard; Linsenmaier, Ulrich; Reiser, Maximilian

    2011-03-01

    Osteoporosis is a chronic condition characterized by demineralization and destruction of bone tissue. Fractures associated with the disease are becoming an increasingly relevant issue for public health institutions. Prediction of fracture risk is a major focus research and, over the years, has been approched by various methods. Still, bone mineral density (BMD) obtained by dual-energy X-ray absorptiometry (DXA) remains the clinical gold-standard for diagnosis and follow-up of osteoporosis. However, DXA is restricted to specialized diagnostic centers and there exists considerable overlap in BMD results between populations of individuals with and without fractures. Clinically far more available than DXA is conventional x-ray imaging depicting trabecular bone structure in great detail. In this paper, we demonstrate that bone structure depicted by clinical radiographs can be analysed quantitatively by parameters obtained from the Radon Transform (RT). RT is a global analysis-tool for detection of predefined, parameterized patterns, e.g. straight lines or struts, representing suitable approximations of trabecular bone texture. The proposed algorithm differentiates between patients with and without fractures of the hip by application of various texture-metrics based on the Radon-Transform to standard x-ray images of the proximal femur. We consider three different regions-of-interest in the proximal femur (femoral head, neck, and inter-trochanteric area), and conduct an analysis with respect to correct classification of the fracture status. Performance of the novel approach is compared to DXA. We draw the conclusion that performance of RT is comparable to DXA and may become a useful supplement to densitometry for the prediction of fracture risk.

  4. Influence of a two-year steroid treatment on body composition as measured by dual X-ray absorptiometry in boys with Duchenne muscular dystrophy.

    PubMed

    Vuillerot, Carole; Braillon, Pierre; Fontaine-Carbonnel, Stephanie; Rippert, Pascal; André, Elisabeth; Iwaz, Jean; Poirot, Isabelle; Bérard, Carole

    2014-06-01

    Steroids are nowadays routinely used as a long-term treatment in Duchenne muscular dystrophy (DMD). Their effects on body composition were assessed using dual X-ray absorptiometry. The study followed over 2 years 29 genetically confirmed DMD patients: 21 in the steroid-treated group and 8 in the steroid-naïve group. After 2 years of steroid treatment, the lean tissue mass values increased significantly (p<0.0001), the percentage of body fat mass remained practically constant (p=0.94) in comparison with the initial visit. In the steroid-naïve patients, there were no significant increases in the lean tissue mass but deterioration in body composition confirmed by a significant increase in the percentage of body fat mass. Besides, significant negative correlations were found between the percentage of body fat mass and the MFM total score (R=-0.79, n=76, p<0.0001). A 2-year steroid treatment improves significantly body composition of boys with DMD through a significant increase in lean tissue mass. We suggest that a thorough check of body composition should be carried out before steroid treatment discontinuation in case of overweight gain. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Evaluating Bone Loss in ISS Astronauts.

    PubMed

    Sibonga, Jean D; Spector, Elisabeth R; Johnston, Smith L; Tarver, William J

    2015-12-01

    The measurement of bone mineral density (BMD) by dual-energy X-ray absorptiometry (DXA) is the Medical Assessment Test used at the NASA Johnson Space Center to evaluate whether prolonged exposure to spaceflight increases the risk for premature osteoporosis in International Space Station (ISS) astronauts. The DXA scans of crewmembers' BMD during the first decade of the ISS existence showed precipitous declines in BMD for the hip and spine after the typical 6-mo missions. However, a concern exists that skeletal integrity cannot be sufficiently assessed solely by DXA measurement of BMD. Consequently, use of relatively new research technologies is being proposed to NASA for risk surveillance and to enhance long-term management of skeletal health in long-duration astronauts. Sibonga JD, Spector ER, Johnston SL, Tarver WJ. Evaluating bone loss in ISS astronauts.

  6. Radiation exposure in X-ray-based imaging techniques used in osteoporosis

    PubMed Central

    Adams, Judith E.; Guglielmi, Giuseppe; Link, Thomas M.

    2010-01-01

    Recent advances in medical X-ray imaging have enabled the development of new techniques capable of assessing not only bone quantity but also structure. This article provides (a) a brief review of the current X-ray methods used for quantitative assessment of the skeleton, (b) data on the levels of radiation exposure associated with these methods and (c) information about radiation safety issues. Radiation doses associated with dual-energy X-ray absorptiometry are very low. However, as with any X-ray imaging technique, each particular examination must always be clinically justified. When an examination is justified, the emphasis must be on dose optimisation of imaging protocols. Dose optimisation is more important for paediatric examinations because children are more vulnerable to radiation than adults. Methods based on multi-detector CT (MDCT) are associated with higher radiation doses. New 3D volumetric hip and spine quantitative computed tomography (QCT) techniques and high-resolution MDCT for evaluation of bone structure deliver doses to patients from 1 to 3 mSv. Low-dose protocols are needed to reduce radiation exposure from these methods and minimise associated health risks. PMID:20559834

  7. Bone remodelling around the Metha short stem in total hip arthroplasty: a prospective dual-energy X-ray absorptiometry study.

    PubMed

    Lerch, Matthias; von der Haar-Tran, Annelene; Windhagen, Henning; Behrens, Bernd A; Wefstaedt, Patrick; Stukenborg-Colsman, Christina M

    2012-03-01

    On the basis of positive clinical results with mid- and long-term follow-up using the Mayo short stem, the Metha neck-preserving stem (BBraun, Aesculap, Tuttlingen, Germany) was introduced. The purpose of this study was to validate the implant design by direct acquisition of bone remodelling data from total hip arthroplasty (THA) recipients using dual-energy X-ray absorptiometry (DEXA). After power analysis, 25 patients were included in this prospective study. Patients were examined clinically and underwent DEXA examinations preoperatively and postoperatively at one week, six months and one and two years after THA. Gruen zones were adapted to the short stem design (R1-R7). The Harris Hip Score (HHS) increased significantly by 31 points. No stem had to be revised. Bone mineral density (BMD) in the greater trochanter decreased significantly from 0.78 g/cm(2) postoperatively to 0.72 g/cm(2) two years after surgery. Marginal changes were seen in the lateral distal regions (R4-R5). In the minor trochanter region, BMD increased significantly after two years by 12.9%. In the calcar region, BMD exceeded the baseline value by 6.1% two years after implantation. Stress shielding seems to occur at the greater trochanter due to the vast cross-section of the implant. However, the aim of proximal load transfer of the Metha stem seems to be partially achieved. DEXA analysis revealed a concentrated load distribution on the medial portion of the femur, which is an important region to guarantee long-term implant survival.

  8. Vertebral fractures assessed with dual-energy X-ray absorptiometry in patients with Addison's disease on glucocorticoid and mineralocorticoid replacement therapy.

    PubMed

    Camozzi, Valentina; Betterle, Corrado; Frigo, Anna Chiara; Zaccariotto, Veronica; Zaninotto, Martina; De Caneva, Erica; Lucato, Paola; Gomiero, Walter; Garelli, Silvia; Sabbadin, Chiara; Salvà, Monica; Costa, Miriam Dalla; Boscaro, Marco; Luisetto, Giovanni

    2018-02-01

    to assess bone damage and metabolic abnormalities in patients with Addison's disease given replacement doses of glucocorticoids and mineralocorticoids. A total of 87 patients and 81 age-matched and sex-matched healthy controls were studied. The following parameters were measured: urinary cortisol, serum calcium, phosphorus, creatinine, 24-h urinary calcium excretion, bone alkaline phosphatase, parathyroid hormone, serum CrossLaps, 25 hydroxyvitamin D, and 1,25 dihydroxyvitamin D. Clear vertebral images were obtained with dual-energy X-ray absorptiometry in 61 Addison's disease patients and 47 controls and assessed using Genant's classification. Nineteen Addison's disease patients (31.1%) had at least one morphometric vertebral fracture, as opposed to six controls (12.8%, odds ratio 3.09, 95% confidence interval 1.12-8.52). There were no significant differences in bone mineral density parameters at any site between patients and controls. In Addison's disease patients, there was a positive correlation between urinary cortisol and urinary calcium excretion. Patients with fractures had a longer history of disease than those without fractures. Patients taking fludrocortisone had a higher bone mineral density than untreated patients at all sites except the lumbar spine. Addison's disease patients have more fragile bones irrespective of any decrease in bone mineral density. Supra-physiological doses of glucocorticoids and longer-standing disease (with a consequently higher glucocorticoid intake) might be the main causes behind patients' increased bone fragility. Associated mineralocorticoid treatment seems to have a protective effect on bone mineral density.

  9. Preliminary research on dual-energy X-ray phase-contrast imaging

    NASA Astrophysics Data System (ADS)

    Han, Hua-Jie; Wang, Sheng-Hao; Gao, Kun; Wang, Zhi-Li; Zhang, Can; Yang, Meng; Zhang, Kai; Zhu, Pei-Ping

    2016-04-01

    Dual-energy X-ray absorptiometry (DEXA) has been widely applied to measure the bone mineral density (BMD) and soft-tissue composition of the human body. However, the use of DEXA is greatly limited for low-Z materials such as soft tissues due to their weak absorption, while X-ray phase-contrast imaging (XPCI) shows significantly improved contrast in comparison with the conventional standard absorption-based X-ray imaging for soft tissues. In this paper, we propose a novel X-ray phase-contrast method to measure the area density of low-Z materials, including a single-energy method and a dual-energy method. The single-energy method is for the area density calculation of one low-Z material, while the dual-energy method aims to calculate the area densities of two low-Z materials simultaneously. Comparing the experimental and simulation results with the theoretical ones, the new method proves to have the potential to replace DEXA in area density measurement. The new method sets the prerequisites for a future precise and low-dose area density calculation method for low-Z materials. Supported by Major State Basic Research Development Program (2012CB825800), Science Fund for Creative Research Groups (11321503) and National Natural Science Foundation of China (11179004, 10979055, 11205189, 11205157)

  10. Differences in Prevalence of Muscle Wasting in Patients Receiving Peritoneal Dialysis per Dual-Energy X-Ray Absorptiometry Due to Variation in Guideline Definitions of Sarcopenia.

    PubMed

    Hung, Rachel; Wong, Bethany; Goldet, Gabrielle; Davenport, Andrew

    2017-08-01

    Muscle wasting is associated with increased risk for mortality. There is no agreed universal definition for muscle wasting (sarcopenia), and we wished to determine whether using different criteria altered the prevalence in patients treated by peritoneal dialysis. We measured lean body and appendicular lean mass indices in 325 outpatients by dual-energy x-ray absorptiometry, comparing muscle mass with that used to define muscle wasting (sarcopenia) by various clinical guideline publications. Lean body and appendicular lean mass indices did not differ by sex: female, 17.7 ± 4.6 kg/m 2 ; male, 17.4 ± 4.3; female, 6.9 (5.6-8.5) kg/m 2 ; male, 6.7 (5.3-8.3), respectively. Depending on the criteria, the prevalence of muscle wasting varied from 2.2%-31.3% for women and 25.1%-75.6% for men. Male patients were older (58.3 ± 16 vs 53.4 ± 15.7 years). Criteria based on cutoffs derived from young healthy patients gave the higher prevalence rates. The prevalence of muscle wasting was not associated with dialysis adequacy, estimated protein intake, duration of dialysis treatment, comorbidity, diabetes, or ethnicity. The prevalence of sarcopenic obesity was low (<5% females, 7% males). We found that the prevalence varied markedly depending on the cutoff criteria used to define muscle wasting. Very few patients had sarcopenic obesity. The higher prevalence for males requires further study but was not associated with dialysis treatment. Our study highlights the need for agreed criteria to define pathologic muscle wasting from that which is age associated to allow for interventional screening programs.

  11. Effect of android fat distribution on thrombin-activatable fibrinolysis inhibitor levels in women with polycystic ovary syndrome.

    PubMed

    Mendonça-Louzeiro, Maria R M F; Andrade, Kleber C; Yela, Daniela A; Benetti-Pinto, Cristina L

    2018-06-21

    Women with polycystic ovary syndrome (PCOS) often present with thromboembolic risk factors, such as obesity, hyperandrogenism, and insulin resistance [1]. Furthermore, some PCOS-related metabolic abnormalities represent cardiovascular risk factors. We aimed to assess the association between hemostatic parameters and clinical and dual-energy X-ray absorptiometry (DXA) measurements of fat distribution in these women. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  12. Muscle strength and soft tissue composition as measured by dual energy x-ray absorptiometry in women aged 18-87 years.

    PubMed

    Madsen, O R; Lauridsen, U B; Hartkopp, A; Sørensen, O H

    1997-01-01

    Dual energy x-ray absorptiometry (DEXA) offers the possibility of assessing regional soft tissue composition, i.e. lean mass (LM) and fat mass: LM may be considered a measure of muscle mass. We examined age-related differences in LM, percentage fat (%fat) and muscle strength in 100 healthy non-athletic women aged 18-87 years. Relationships between muscle strength and leg LM in 20 elite female weight lifters and in 18 inactive women with previous hip fractures were also studied. The LM and %fat of the whole body, trunk, arms and legs were derived from a whole body DEXA scan. Isokinetic knee extensor strength (KES) and flexor strength (KFS) at 30 degrees.s-1 were assessed using an isokinetic dynamometer. The women aged 71-87 years had 35% lower KES and KFS than the women aged 18-40 years (P < 0.0001). Differences in LM were less pronounced. The LM of the legs, for instance, was 15% lower in the old than in the young women (P < 0.0001). In a multiple regression analysis with age, body mass, height and leg LM or KES as independent variables and KES or leg LM as the dependent variable, age was the most important predictor of KES (r(partial) = -0.74, P < 0.0001). The same applied to KFS. Body mass, not age, was the most important predictor of leg LM (r(partial) = 0.65, P < 0.0001) and of LM at all other measurement sites. The LM measured at different regions decreased equally with increasing age. The KES:leg LM ratio was negatively correlated with age (r = -0.70, P < 0.0001). The weight lifters had significantly higher KES:leg LM ratios than age-matched controls (+ 12%, P < 0.0001) and vice versa for the women with previous hip fractures (-36%, P < 0.0001). In conclusion, from our study it would seem that in healthy nonathletic women, age is a more important determinant of muscle strength than is LM as measured by DEXA. Muscle strengthening exercises and inactivity seem to have a considerably stronger influence on muscle strength than on LM.

  13. Pediatric data for dual X-ray absorptiometric measures of normal lumbar bone mineral density in children under 5 years of age using the lunar prodigy densitometer.

    PubMed

    Manousaki, D; Rauch, F; Chabot, G; Dubois, J; Fiscaletti, M; Alos, N

    2016-09-07

    Knowledge of physiological variations of bone mineral density (BMD) in newborns and infants is necessary to evaluate pathological changes associated with fractures. Limited reference data for children under 5 years old are available. This study provides normative data of lumbar BMD for the Lunar Prodigy in young children under 5 years old. We assessed cross-sectionally 155 healthy children (77 boys, 80% Caucasian), ranging in age from newborn to the age of 5 years. Lumbar bone mineral content (BMC) and areal BMD were measured by dual-energy X-ray absorptiometry using a Lunar Prodigy absorptiometer. Volumetric BMD was calculated using the Kroeger and Carter methods. BMC and areal BMD increased from birth to 5 years (p<0.001). Volumetric BMD did not change with age. BMD and BMC correlated with age, weight and height (R(2)≥0.85 for all), with a maximum gain between the ages of 1 and 4 years, which did not follow the same pattern as height velocity. We did not find significant sex difference for any of the three measured parameters. This study provides normative data for lumbar spine densitometry of infants and young children using the Lunar Prodigy DXA system.

  14. Use of magnetic resonance imaging to predict the body composition of pigs in vivo.

    PubMed

    Kremer, P V; Förster, M; Scholz, A M

    2013-06-01

    The objective of the study was to evaluate whether magnetic resonance imaging (MRI) offers the opportunity to reliably analyze body composition of pigs in vivo. Therefore, the relation between areas of loin eye muscle and its back fat based on MRI images were used to predict body composition values measured by dual energy X-ray absorptiometry (DXA). During the study, a total of 77 pigs were studied by MRI and DXA, with a BW ranging between 42 and 102 kg. The pigs originated from different extensive or conventional breeds or crossbreds such as Cerdo Iberico, Duroc, German Landrace, German Large White, Hampshire and Pietrain. A Siemens Magnetom Open was used for MRI in the thorax region between 13th and 14th vertebrae in order to measure the loin eye area (MRI-LA) and the above back fat area (MRI-FA) of both body sides, whereas a whole body scan was performed by DXA with a GE Lunar DPX-IQ in order to measure the amount and percentage of fat tissue (DXA-FM; DXA-%FM) and lean tissue mass (DXA-LM; DXA-%LM). A linear single regression analysis was performed to quantify the linear relationships between MRI- and DXA-derived traits. In addition, a stepwise regression procedure was carried out to calculate (multiple) regression equations between MRI and DXA variables (including BW). Single regression analyses showed high relationships between DXA-%FM and MRI-FA (R 2 = 0.89, √MSE = 2.39%), DXA-FM and MRI-FA (R 2 = 0.82, √MSE = 2757 g) and DXA-LM and MRI-LA (R 2 = 0.82, √MSE = 4018 g). Only DXA-%LM and MRI-LA did not show any relationship (R 2 = 0). As a result of the multiple regression analysis, DXA-LM and DXA-FM were both highly related to MRI-LA, MRI-FA and BW (R 2 = 0.96; √MSE = 1784 g, and R 2 = 0.95, √MSE = 1496 g). Therefore, it can be concluded that the use of MRI-derived images provides exact information about important 'carcass-traits' in pigs and may be used to reliably predict the body composition in vivo.

  15. Predictive Validity of the Body Adiposity Index in Overweight and Obese Adults Using Dual-Energy X-ray Absorptiometry

    PubMed Central

    Ramírez-Vélez, Robinson; Correa-Bautista, Jorge Enrique; González-Ruíz, Katherine; Vivas, Andrés; García-Hermoso, Antonio; Triana-Reina, Hector Reynaldo

    2016-01-01

    The body adiposity index (BAI) is a recent anthropometric measure proven to be valid in predicting body fat percentage (BF%) in some populations. However, the results have been inconsistent across populations. This study was designed to verify the validity of BAI in predicting BF% in a sample of overweight/obese adults, using dual-energy X-ray absorptiometry (DEXA) as the reference method. A cross-sectional study was conducted in 48 participants (54% women, mean age 41.0 ± 7.3 years old). DEXA was used as the “gold standard” to determine BF%. Pearson’s correlation coefficient was used to evaluate the association between BAI and BF%, as assessed by DEXA. A paired sample t-test was used to test differences in mean BF% obtained with BAI and DEXA methods. To evaluate the concordance between BF% as measured by DEXA and as estimated by BAI, we used Lin’s concordance correlation coefficient and Bland–Altman agreement analysis. The correlation between BF% obtained by DEXA and that estimated by BAI was r = 0.844, p < 0.001. Paired t-test showed a significant mean difference in BF% between methods (BAI = 33.3 ± 6.2 vs. DEXA 39.0 ± 6.1; p < 0.001). The bias of the BAI was −6.0 ± 3.0 BF% (95% CI = −12.0 to 1.0), indicating that the BAI method significantly underestimated the BF% compared to the reference method. Lin’s concordance correlation coefficient was considered stronger (ρc = 0.923, 95% CI = 0.862 to 0.957). In obese adults, BAI presented low agreement with BF% measured by DEXA; therefore, BAI is not recommended for BF% prediction in this overweight/obese sample studied. PMID:27916871

  16. Body composition in males with adolescent idiopathic scoliosis: a case-control study with dual-energy X-ray absorptiometry.

    PubMed

    Wang, Weijun; Wang, Zhiwei; Zhu, Zezhang; Zhu, Feng; Qiu, Yong

    2016-02-29

    In contrast to the well-characterized body growth and development of females with adolescent idiopathic scoliosis (AIS), the pubertal growth pattern of male patients has not been well-documented. Recently, significantly lower body weight (BW) and body mass index (BMI) were reported in males with AIS, and were thought to be related to curve progression. A case-control study was carried out to characterize the body composition and bone status of males with AIS, with the aim of gaining a better understanding of lower BW among these patients. Forty-seven males with AIS and forty age- and gender-matched healthy controls were recruited. Standing height (SH) and BW were measured. The SH of the males who had AIS was corrected using Bjure's equation, and then the BMI was calculated. Body composition, including subcranial fat mass (FM), lean mass (LM), and bone mineral content (BMC), and bone mineral density (BMD) were analyzed using dual-energy X-ray absorptiometry. The LM index (LMi) and the FM index (FMi) were calculated by dividing the FM and LM by the square of the SH. Logistic regression analysis was employed for comparison between AIS and controls. The AIS patients had comparable age and Tanner staging for pubic hair as the controls. After adjustment for age, the AIS patients showed comparable SH but significantly lower BW and BMI than that of the controls. The LM, LMi, BMC and BMD were also significantly lower in the AIS patients than in the controls. However, the difference in BMC between two groups was not significant by adjusting for age, FM and LM. The male AIS patients showed abnormal body composition, presenting as significantly lower LM than the controls. The lower BMC observed in the patients might due to the abnormal body composition.

  17. Trabecular bone score (TBS): Method and applications.

    PubMed

    Martineau, P; Leslie, W D

    2017-11-01

    Trabecular bone score (TBS) is a texture index derived from standard lumbar spine dual energy X-ray absorptiometry (DXA) images and provides information about the underlying bone independent of the bone mineral density (BMD). Several salient observations have emerged. Numerous studies have examined the relationship between TBS and fracture risk and have shown that lower TBS values are associated with increased risk for major osteoporotic fracture in postmenopausal women and older men, with this result being independent of BMD values and other clinical risk factors. Therefore, despite being derived from standard DXA images, the information contained in TBS is independent and complementary to the information provided by BMD and the FRAX® tool. A procedure to generate TBS-adjusted FRAX probabilities has become available with the resultant predicted fracture risks shown to be more accurate than the standard FRAX tool. With these developments, TBS has emerged as a clinical tool for improved fracture risk prediction and guiding decisions regarding treatment initiation, particularly for patients with FRAX probabilities around an intervention threshold. In this article, we review the development, validation, clinical application, and limitations of TBS. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Quantitative imaging methods in osteoporosis.

    PubMed

    Oei, Ling; Koromani, Fjorda; Rivadeneira, Fernando; Zillikens, M Carola; Oei, Edwin H G

    2016-12-01

    Osteoporosis is characterized by a decreased bone mass and quality resulting in an increased fracture risk. Quantitative imaging methods are critical in the diagnosis and follow-up of treatment effects in osteoporosis. Prior radiographic vertebral fractures and bone mineral density (BMD) as a quantitative parameter derived from dual-energy X-ray absorptiometry (DXA) are among the strongest known predictors of future osteoporotic fractures. Therefore, current clinical decision making relies heavily on accurate assessment of these imaging features. Further, novel quantitative techniques are being developed to appraise additional characteristics of osteoporosis including three-dimensional bone architecture with quantitative computed tomography (QCT). Dedicated high-resolution (HR) CT equipment is available to enhance image quality. At the other end of the spectrum, by utilizing post-processing techniques such as the trabecular bone score (TBS) information on three-dimensional architecture can be derived from DXA images. Further developments in magnetic resonance imaging (MRI) seem promising to not only capture bone micro-architecture but also characterize processes at the molecular level. This review provides an overview of various quantitative imaging techniques based on different radiological modalities utilized in clinical osteoporosis care and research.

  19. MRI-measured bone marrow adipose tissue is inversely related to DXA-measured bone mineral in Caucasian women.

    PubMed

    Shen, W; Chen, J; Punyanitya, M; Shapses, S; Heshka, S; Heymsfield, S B

    2007-05-01

    Recent studies suggest that bone marrow adipose tissue (BMAT) might play a role in the pathogenesis of osteoporosis. Previous research using regional magnetic resonance spectroscopy methods to measure BMAT has reported inconsistent findings on the relationship between BMAT and dual-energy absorptiometry (DXA)-measured bone mineral density (BMD). In the present study, total body and pelvic BMAT were evaluated in 56 healthy women (age 18-88 yrs, mean +/- SD, 47.4 +/- 17.6 yrs; BMI, 24.3 +/- 4.2 kg/m(2)) with T1-weighted whole-body magnetic resonance imaging (MRI). BMD was measured using the whole-body DXA mode (GE Lunar DPX, software version 4.7). A strong negative correlation was observed between pelvic BMAT and BMD (total-body BMD, R = -0.743, P < 0.001; pelvic BMD, R = -0.646, P < 0.001), and between total-body BMAT and BMD (total-body BMD, R = -0.443, P < 0.001; pelvic BMD, R = -0.308, P < 0.001). The inverse association between pelvic BMAT and BMD remained strong after adjusting for age, weight, total body fat, and menopausal status (partial correlation: total-body BMD, R = -0.553, P < 0.001; pelvic BMD, R = -0.513, P < 0.001). BMAT was also highly correlated with age (pelvic BMAT, R = 0.715, P < 0.001; total-body BMAT, R = 0.519, P < 0.001). MRI-measured BMAT is thus strongly inversely correlated with DXA-measured BMD independent of other predictor variables. These observations, in the context of DXA technical concerns, support the growing evidence linking BMAT with low bone density.

  20. Comparison of Body Composition Assessed by Dual-Energy X-Ray Absorptiometry and BMI in Current and Former U.S. Navy Service Members.

    PubMed

    Gasier, Heath G; Hughes, Linda M; Young, Colin R; Richardson, Annely M

    2015-01-01

    Little is known of the diagnostic accuracy of BMI in classifying obesity in active duty military personnel and those that previously served. Thus, the primary objectives were to determine the relationship between lean and fat mass, and body fat percentage (BF%) with BMI, and assess the agreement between BMI and BF% in defining obesity. Body composition was measured by dual-energy X-ray absorptiometry in 462 males (20-91 years old) who currently or previously served in the U.S. Navy. A BMI of ≥ 30 kg/m2 and a BF% ≥ 25% were used for obesity classification. The mean BMI (± SD) and BF% were 28.8 ± 4.1 and 28.9 ± 6.6%, respectively, with BF% increasing with age. Lean mass, fat mass, and BF% were significantly correlated with BMI for all age groups. The exact agreement of obesity defined by BMI and BF% was fair (61%), however, 38% were misclassified by a BMI cut-off of 30 when obesity was defined by BF%. From this data we determined that there is a good correlation between body composition and BMI, and fair agreement between BMI and BF% in classifying obesity in a group of current and former U.S. Navy service members. However, as observed in the general population, a significant proportion of individuals with excess fat are misclassified by BMI cutoffs.

  1. Changes in Body Fat Distribution on Dual-Energy X-Ray Absorptiometry in Black South Africans Starting First-Line Antiretroviral Therapy.

    PubMed

    Abrahams, Zulfa; Levitt, Naomi; Lesosky, Maia; Maartens, Gary; Dave, Joel

    2016-10-01

    Long-term use of antiretroviral therapy (ART) increases the risk of developing lipodystrophy. Few studies from Africa have used longitudinal data to assess the development of lipoatrophy and lipohypertrophy. We use clinical anthropometry and dual-energy X-ray absorptiometry (DEXA) to describe changes in body fat distribution over a 24-month period in individuals initiated on ART. A convenience sample of black South Africans (55 men and 132 women) were recruited and followed for 24 months after commencing ART. Body fat distribution was assessed using anthropometric measurements and DEXA scans at baseline and then at 3, 6, 12, 18, and 24 months after commencing ART. DEXA was also used to estimate abdominal visceral adipose tissue (VAT) and subcutaneous adipose tissue (SAT). Women gained more overall weight and more regional fat in all areas analyzed on DEXA scans. Women, not men, experienced a significant increasing trend in trunk fat and a significant decreasing trend in limb fat, when expressed as a percentage of total body fat. In men, the risk of developing lipoatrophy was more than two times greater than that of women, after adjusting for age, baseline body mass index, and ART regimen. Lipohypertrophy occurred similarly in men and women. VAT and SAT increased significantly in men and women, with women gaining considerably more than men. These findings are of great concern as an increased waist circumference is associated with increased mortality in HIV-infected populations. Further investigation is required to understand the mechanisms underlying the sex differences in changes in body fat distribution and its effects on cardiovascular risk.

  2. Total body composition estimated by standing-posture 8-electrode bioelectrical impedance analysis in male wrestlers.

    PubMed

    Cheng, M-F; Chen, Y-Y; Jang, T-R; Lin, W-L; Chen, J; Hsieh, K-C

    2016-12-01

    Standing-posture 8-electrode bioelectrical impedance analysis is a fast and practical method for evaluating body composition in clinical settings, which can be used to estimate percentage body fat (BF%) and skeletal muscle mass in a subject's total body and body segments. In this study, dual-energy X-ray absorptiometry (DXA) was used as a reference method for validating the standing 8-electrode bioelectrical impedance analysis device BC-418 (BIA 8 , Tanita Corp., Tokyo, Japan). Forty-eight Taiwanese male wrestlers aged from 17.9 to 22.3 years volunteered to participate in this study. The lean soft tissue (LST) and BF% in the total body and body segments were measured in each subject by the BIA 8 and DXA. The correlation coefficients between total body, arm, leg segments impedance index (BI, ht 2 /Z) and lean soft tissue mass measured from DXA were r = 0.902, 0.453, 0.885, respectively (p < 0.01). In addition, the total body and segmental LST estimated by the BIA 8 were highly correlated with the DXA data (r = 0.936, 0.466, 0.886, p < 0.01). The estimation of total body and segmental BF% measured by BIA 8 and DXA also showed a significant correlation (r > 0.820, p < 0.01). The estimated LST and BF% from BIA 8 in the total body and body segments were highly correlated with the DXA results, which indicated that the standing-posture 8-electrode bioelectrical impedance analysis may be used to derive reference measures of LST and BF% in Taiwanese male wrestlers.

  3. Total body composition estimated by standing-posture 8-electrode bioelectrical impedance analysis in male wrestlers

    PubMed Central

    Cheng, M-F; Chen, Y-Y; Jang, T-R; Lin, W-L; Chen, J

    2015-01-01

    Standing-posture 8-electrode bioelectrical impedance analysis is a fast and practical method for evaluating body composition in clinical settings, which can be used to estimate percentage body fat (BF%) and skeletal muscle mass in a subject’s total body and body segments. In this study, dual-energy X-ray absorptiometry (DXA) was used as a reference method for validating the standing 8-electrode bioelectrical impedance analysis device BC-418 (BIA8, Tanita Corp., Tokyo, Japan). Forty-eight Taiwanese male wrestlers aged from 17.9 to 22.3 years volunteered to participate in this study. The lean soft tissue (LST) and BF% in the total body and body segments were measured in each subject by the BIA8 and DXA. The correlation coefficients between total body, arm, leg segments impedance index (BI, ht2/Z) and lean soft tissue mass measured from DXA were r = 0.902, 0.453, 0.885, respectively (p < 0.01). In addition, the total body and segmental LST estimated by the BIA8 were highly correlated with the DXA data (r = 0.936, 0.466, 0.886, p < 0.01). The estimation of total body and segmental BF% measured by BIA8 and DXA also showed a significant correlation (r > 0.820, p < 0.01). The estimated LST and BF% from BIA8 in the total body and body segments were highly correlated with the DXA results, which indicated that the standing-posture 8-electrode bioelectrical impedance analysis may be used to derive reference measures of LST and BF% in Taiwanese male wrestlers. PMID:28090145

  4. Comparison of body adiposity index (BAI) and BMI with estimations of % body fat in clinically severe obese women.

    PubMed

    Geliebter, Allan; Atalayer, Deniz; Flancbaum, Louis; Gibson, Charlisa D

    2013-03-01

    Body adiposity index (BAI), a new surrogate measure of body fat (hip circumference/(height(1.5) - 18)), has been proposed as an alternative to body mass index (BMI). We compared BAI with BMI, and each of them with laboratory measures of body fat-derived from bioimpedance analysis (BIA), air displacement plethysmography (ADP), and dual-energy X-ray absorptiometry (DXA) in clinically severe obese (CSO) participants. Nineteen prebariatric surgery CSO, nondiabetic women were recruited (age = 32.6 ± 7.7 SD; BMI = 46.5 ± 9.0 kg/m(2) ). Anthropometrics and body fat percentage (% fat) were determined from BIA, ADP, and DXA. Scatter plots with lines of equality and Bland-Altman plots were used to compare BAI and BMI with % fat derived from BIA, ADP, and DXA. BAI and BMI correlated highly with each other (r = 0.90, P < 0.001). Both BAI and BMI correlated significantly with % fat from BIA and ADP. BAI, however, did not correlate significantly with % fat from DXA (r = 0.42, P = 0.08) whereas BMI did (r = 0.65, P = 0.003). BMI was also the single best predictor of % fat from both BIA (r(2) = 0.80, P < 0.001) and ADP (r(2) = 0.65, P < 0.001). The regression analysis showed that the standard error of the estimate (SEE), or residual error around the regression lines, was greater for BAI comparisons than for BMI comparisons with BIA, ADP, and DXA. Consistent with this, the Bland and Altman plots indicated wider 95% confidence intervals for BAI difference comparisons than for BMI difference comparisons for their respective means for BIA, ADP, and DXA. Thus, BAI does not appear to be an appropriate proxy for BMI in CSO women. Copyright © 2012 The Obesity Society.

  5. Novel X-ray Communication Based XNAV Augmentation Method Using X-ray Detectors

    PubMed Central

    Song, Shibin; Xu, Luping; Zhang, Hua; Bai, Yuanjie

    2015-01-01

    The further development of X-ray pulsar-based NAVigation (XNAV) is hindered by its lack of accuracy, so accuracy improvement has become a critical issue for XNAV. In this paper, an XNAV augmentation method which utilizes both pulsar observation and X-ray ranging observation for navigation filtering is proposed to deal with this issue. As a newly emerged concept, X-ray communication (XCOM) shows great potential in space exploration. X-ray ranging, derived from XCOM, could achieve high accuracy in range measurement, which could provide accurate information for XNAV. For the proposed method, the measurement models of pulsar observation and range measurement observation are established, and a Kalman filtering algorithm based on the observations and orbit dynamics is proposed to estimate the position and velocity of a spacecraft. A performance comparison of the proposed method with the traditional pulsar observation method is conducted by numerical experiments. Besides, the parameters that influence the performance of the proposed method, such as the pulsar observation time, the SNR of the ranging signal, etc., are analyzed and evaluated by numerical experiments. PMID:26404295

  6. Trabecular Bone Score (TBS)—A Novel Method to Evaluate Bone Microarchitectural Texture in Patients With Primary Hyperparathyroidism

    PubMed Central

    Boutroy, Stephanie; Zhang, Chiyuan; McMahon, Donald Jay; Zhou, Bin; Wang, Ji; Udesky, Julia; Cremers, Serge; Sarquis, Marta; Guo, Xiang-Dong Edward; Hans, Didier

    2013-01-01

    Context: In the milder form of primary hyperparathyroidism (PHPT), cancellous bone, represented by areal bone mineral density at the lumbar spine by dual-energy x-ray absorptiometry (DXA), is preserved. This finding is in contrast to high-resolution peripheral quantitative computed tomography (HRpQCT) results of abnormal trabecular microstructure and epidemiological evidence for increased overall fracture risk in PHPT. Because DXA does not directly measure trabecular bone and HRpQCT is not widely available, we used trabecular bone score (TBS), a novel gray-level textural analysis applied to spine DXA images, to estimate indirectly trabecular microarchitecture. Objective: The purpose of this study was to assess TBS from spine DXA images in relation to HRpQCT indices and bone stiffness in radius and tibia in PHPT. Design and Setting: This was a cross-sectional study conducted in a referral center. Patients: Participants were 22 postmenopausal women with PHPT. Main Outcome Measures: Outcomes measured were areal bone mineral density by DXA, TBS indices derived from DXA images, HRpQCT standard measures, and bone stiffness assessed by finite element analysis at distal radius and tibia. Results: TBS in PHPT was low at 1.24, representing abnormal trabecular microstructure (normal ≥1.35). TBS was correlated with whole bone stiffness and all HRpQCT indices, except for trabecular thickness and trabecular stiffness at the radius. At the tibia, correlations were observed between TBS and volumetric densities, cortical thickness, trabecular bone volume, and whole bone stiffness. TBS correlated with all indices of trabecular microarchitecture, except trabecular thickness, after adjustment for body weight. Conclusion: TBS, a measurement technology readily available by DXA, shows promise in the clinical assessment of trabecular microstructure in PHPT. PMID:23526463

  7. Current methods and advances in bone densitometry

    NASA Technical Reports Server (NTRS)

    Guglielmi, G.; Gluer, C. C.; Majumdar, S.; Blunt, B. A.; Genant, H. K.

    1995-01-01

    Bone mass is the primary, although not the only, determinant of fracture. Over the past few years a number of noninvasive techniques have been developed to more sensitively quantitate bone mass. These include single and dual photon absorptiometry (SPA and DPA), single and dual X-ray absorptiometry (SXA and DXA) and quantitative computed tomography (QCT). While differing in anatomic sites measured and in their estimates of precision, accuracy, and fracture discrimination, all of these methods provide clinically useful measurements of skeletal status. It is the intent of this review to discuss the pros and cons of these techniques and to present the new applications of ultrasound (US) and magnetic resonance (MRI) in the detection and management of osteoporosis.

  8. Monitoring X-Ray Emission from X-Ray Bursters

    NASA Technical Reports Server (NTRS)

    Halpern, Jules P.; Kaaret, Philip

    1999-01-01

    The scientific goal of this project was to monitor a selected sample of x-ray bursters using data from the All-Sky Monitor (ASM) on the Rossi X-Ray Timing Explorer together with data from the Burst and Transient Source Experiment (BATSE) on the Compton Gamma-Ray Observatory to study the long-term temporal evolution of these sources in the x-ray and hard x-ray bands. The project was closely related to "Long-Term Hard X-Ray Monitoring of X-Ray Bursters", NASA project NAG5-3891, and and "Hard x-ray emission of x-ray bursters", NASA project NAG5-4633, and shares publications in common with both of these. The project involved preparation of software for use in monitoring and then the actual monitoring itself. These efforts have lead to results directly from the ASM data and also from Target of Opportunity Observations (TOO) made with the Rossi X-Ray Timing Explorer based on detection of transient hard x-ray outbursts with the ASM and BATSE.

  9. MRI-measured bone marrow adipose tissue is inversely related to DXA-measured bone mineral in Caucasian women

    PubMed Central

    Chen, J.; Punyanitya, M.; Shapses, S.; Heshka, S.; Heymsfield, S. B.

    2007-01-01

    Introduction Recent studies suggest that bone marrow adipose tissue (BMAT) might play a role in the pathogenesis of osteoporosis. Previous research using regional magnetic resonance spectroscopy methods to measure BMAT has reported inconsistent findings on the relationship between BMAT and dual-energy absorptiometry (DXA)-measured bone mineral density (BMD). Methods In the present study, total body and pelvic BMAT were evaluated in 56 healthy women (age 18–88 yrs, mean±SD, 47.4±17.6 yrs; BMI, 24.3±4.2 kg/m2) with T1-weighted whole-body magnetic resonance imaging (MRI). BMD was measured using the whole-body DXA mode (GE Lunar DPX, software version 4.7). Results A strong negative correlation was observed between pelvic BMAT and BMD (total-body BMD, R=− 0.743, P<0.001; pelvic BMD, R=− 0.646, P<0.001), and between total-body BMAT and BMD (total-body BMD, R=− 0.443, P<0.001; pelvic BMD, R=− 0.308, P < 0.001). The inverse association between pelvic BMAT and BMD remained strong after adjusting for age, weight, total body fat, and menopausal status (partial correlation: total-body BMD, R=− 0.553, P< 0.001; pelvic BMD, R=− 0.513, P<0.001). BMAT was also highly correlated with age (pelvic BMAT, R=0.715, P< 0.001; total-body BMAT, R=0.519, P<0.001). Conclusion MRI-measured BMAT is thus strongly inversely correlated with DXA-measured BMD independent of other predictor variables. These observations, in the context of DXA technical concerns, support the growing evidence linking BMAT with low bone density. PMID:17139464

  10. An Investigation Into the Differences in Bone Density and Body Composition Measurements Between 2 GE Lunar Densitometers and Their Comparison to a 4-Component Model.

    PubMed

    Watson, Laura P E; Venables, Michelle C; Murgatroyd, Peter R

    We describe a study to assess the precision of the GE Lunar iDXA and the agreement between the iDXA and GE Lunar Prodigy densitometers for the measurement of regional- and total-body bone and body composition in normal to obese healthy adults. We compare the whole-body fat mass by dual-energy X-ray absorptiometry (DXA) to measurements by a 4-component (4-C) model. Sixty-nine participants, aged 37 ± 12 yr, with a body mass index of 26.2 ± 5.1 kg/cm 2 , were measured once on the Prodigy and twice on the iDXA. The 4-C model estimated fat mass from body mass, total body water by deuterium dilution, body volume by air displacement plethysmography, and bone mass by DXA. Agreements between measurements made on the 2 instruments and by the 4-C model were analyzed by Bland-Altman and linear regression analyses. Where appropriate, translational cross-calibration equations were derived. Differences between DXA software versions were investigated. iDXA precision was less than 2% of the measured value for all regional- and whole-body bone and body composition measurements with the exception of arm fat mass (2.28%). We found significant differences between iDXA and Prodigy (p < 0.05) whole-body and regional bone, fat mass (FM), and lean mass, with the exception of hip bone mass, area and density, and spine area. Compared to iDXA, Prodigy overestimated FM and underestimated lean mass. However, compared to 4-C, iDXA showed a smaller bias and narrower limits of agreement than Prodigy. No significant differences between software versions in FM estimations existed. Our results demonstrate excellent iDXA precision. However, significant differences exist between the 2 GE Lunar instruments, Prodigy and iDXA measurement values. A divergence from the reference 4-C observations remains in FM estimations made by DXA even following the recent advances in technology. Further studies are particularly warranted in individuals with large FM contents. Copyright © 2017. Published

  11. The 2014 X-Ray Minimum of Eta Carinae as Seen by Swift

    NASA Technical Reports Server (NTRS)

    Corcoran, M. F.; Liburd, J.; Morris, D.; Russell, C. M. P.; Hamaguchi, K.; Gull, T. R.; Madura, T. I.; Teodoro, M.; Moffat, A. F. J.; Richardson, N. D.

    2017-01-01

    We report on Swift X-ray Telescope observations of Eta Carinae ( Car), an extremely massive, long-period, highly eccentric binary obtained during the 2014.6 X-ray minimumperiastron passage. These observations show that Car may have been particularly bright in X-rays going into the X-ray minimum state, while the duration of the 2014 X-ray minimum was intermediate between the extended minima seen in 1998.0 and 2003.5 by Rossi X-Ray Timing Explorer (RXTE), and the shorter minimum in 2009.0. The hardness ratios derived from the Swift observations showed a relatively smooth increase to a peak value occurring 40.5 days after the start of the X-ray minimum, though these observations cannot reliably measure the X-ray hardness during the deepest part of the X-ray minimum when contamination by the central constant emission component is significant. By comparing the timings of the RXTE and Swift observations near the X-ray minima, we derive an updated X-ray period of P X equals 2023.7 +/- 0.7 days, in good agreement with periods derived from observations at other wavelengths, and we compare the X-ray changes with variations in the He ii lambda 4686 emission. The middle of the Deep Minimum interval, as defined by the Swift column density variations, is in good agreement with the time of periastron passage derived from the He ii 4686 line variations.

  12. The 2014 X-Ray Minimum of η Carinae as Seen by Swift

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Corcoran, M. F.; Hamaguchi, K.; Liburd, J.

    We report on Swift X-ray Telescope observations of Eta Carinae ( η Car), an extremely massive, long-period, highly eccentric binary obtained during the 2014.6 X-ray minimum/periastron passage. These observations show that η Car may have been particularly bright in X-rays going into the X-ray minimum state, while the duration of the 2014 X-ray minimum was intermediate between the extended minima seen in 1998.0 and 2003.5 by Rossi X-Ray Timing Explorer ( RXTE ), and the shorter minimum in 2009.0. The hardness ratios derived from the Swift observations showed a relatively smooth increase to a peak value occurring 40.5 days aftermore » the start of the X-ray minimum, though these observations cannot reliably measure the X-ray hardness during the deepest part of the X-ray minimum when contamination by the “central constant emission” component is significant. By comparing the timings of the RXTE and Swift observations near the X-ray minima, we derive an updated X-ray period of P {sub X} = 2023.7 ± 0.7 days, in good agreement with periods derived from observations at other wavelengths, and we compare the X-ray changes with variations in the He ii 4686 emission. The middle of the “Deep Minimum” interval, as defined by the Swift column density variations, is in good agreement with the time of periastron passage derived from the He ii λ 4686 line variations.« less

  13. Comparison of two bioelectrical impedance devices and dual-energy X-ray absorptiometry to evaluate body composition in heart failure.

    PubMed

    Alves, F D; Souza, G C; Biolo, A; Clausell, N

    2014-12-01

    The utilisation of bioelectrical impedance analysis (BIA) in heart failure can be affected by many factors and its applicability remains controversial. The present study aimed to verify the adequacy of single-frequency BIA (SF-BIA) and multifrequency BIA (MF-BIA) compared to dual-energy x-ray absorptiometry (DEXA) for evaluating body composition in outpatients with heart failure. In this cross-sectional study, 55 patients with stable heart failure and left ventricle ejection fraction ≤45% were evaluated for fat mass percentage, fat mass and fat-free mass by DEXA and compared with the results obtained by SF-BIA (single frequency of 50 kHz) and MF-BIA (frequencies of 20 and 100 kHz). MF-BIA and DEXA gave similar mean values for fat mass percentage, fat mass and fat-free mass, whereas values from SF-BIA were significantly different from DEXA. Both SF-BIA and MF-BIA measures of body composition correlated strongly with DEXA (r > 0.8; P < 0.001), except for fat mass assessed by SF-BIA, which showed a moderate correlation (r = 0.760; P < 0.001). MF-BIA also showed a better agreement with DEXA by Bland-Altman analysis in all measurements. However, both types of equipment showed wide limits of agreement and a significant relationship between variance and bias (Pitmans's test P > 0.05), except MF-BIA for fat-free mass. Compared with DEXA, MF-BIA showed better accuracy than SF-BIA, although both types of equipment showed wide limits of agreement. The BIA technique should be used with caution, and regression equations might be useful for correcting the observed variations, mainly in extreme values of body composition. © 2014 The British Dietetic Association Ltd.

  14. Are adult patients with Laron syndrome osteopenic? A comparison between dual-energy X-ray absorptiometry and volumetric bone densities.

    PubMed

    Benbassat, Carlos A; Eshed, Varda; Kamjin, Moshe; Laron, Zvi

    2003-10-01

    Severe short stature resulting from a deficiency in IGF-I is a prominent feature of Laron syndrome (LS). Although low bone mineral density (BMD) has been noted in LS patients examined by dual energy x-ray absorptiometry (DEXA), this technique does not take volume into account and may therefore underestimate the true bone density in patients with small bones. The aim of the present study was to evaluate the BMD yielded by DEXA in our LS patients using estimated volumetric values. Volumetric density was calculated with the following formulas: bone mineral apparent density (BMAD) = bone mineral content (BMC)/(area)(3/2) for the lumbar spine and BMAD = BMC/area(2) for the femoral neck. The study sample included 12 patients (mean age, 43.9 yr; mean height, 123.7 cm). Findings were compared with 10 osteopenic subjects without developmental abnormalities (mean age, 56 yr; mean height, 164.8 cm) and 10 healthy control subjects matched for sex and age to the LS patients (mean height, 165.5 cm). BMAD in the LS group was 0.201 +/- 0.02 g/cm(3) at the lumbar spine and 0.201 +/- 0.04 g/cm(3) at the femoral neck; corresponding values for the osteopenic group were 0.130 +/- 0.01 and 0.140 +/- 0.01 g/cm(3), and for the controls, 0.178 +/- 0.03 and 0.192 +/- 0.02 g/cm(3). Although areal BMD was significantly lower in the LS and osteopenic subjects compared with controls (P < 0.02) at both the lumbar spine and femoral neck, BMAD was low (P < 0.01) in the osteopenic group only. In conclusion, DEXA does not seem to be a reliable measure of osteoporosis in patients with LS.

  15. Femoral Neck X-Ray Absorptiometry Parameters and Peripheral Quantitative Computer Tomography Tibial Cortical Density Predict Survival in Dialysis Patients.

    PubMed

    Yap, Natalie; Wong, Phillip; McGinn, Stella; Nery, Maria-Liza; Doyle, Jean; Wells, Lynda; Clifton-Bligh, Phillip; Clifton-Bligh, Roderick J

    2017-01-01

    Low bone mineral density (BMD) is a known independent predictor of mortality in the general elderly population. However, studies in patients with end-stage renal disease (ESRD) are limited. The present study evaluated mortality during long-term follow-up in a population of patients having dialysis for ESRD, in whom BMD was also measured. Fifty-eight patients with ESRD were recruited consecutively from a dialysis clinic and followed prospectively for 6 years. Baseline BMD of the lumbar spine and femoral neck (FN) were measured by X-ray absorptiometry and by peripheral quantitative CT at the radius and tibia. Serum calcium, phosphate, parathyroid hormone (PTH), and albumin were measured at baseline. During follow-up, 25 patients died. Univariate analysis showed that mortality was significantly associated with FN-BMD: hazards ratio (HR) per 0.1 g/cm2 decrease 1.50 (95% CI 1.07-2.10), p = 0.019; FN-T score: HR per 1-SD decrease 1.84 (95% CI 1.16-2.92), p = 0.009; and tibial cortical density: HR per 10 mg/cm3 decrease 1.08 (95% CI 1.02-1.14), p = 0.010. In multivariate analysis with stepwise adjustment for age, sex, transplant status, albumin, PTH, phosphate, dialysis duration, diabetes, and smoking, FN-T score remained significantly associated with mortality: HR per 1-SD decrease 1.82 (95% CI 1.02-3.24), p = 0.044, whereas the HR for FN-BMD and tibial cortical density were no longer significant. When 4 patients who had peritoneal dialysis were excluded, the HR relating FN-BMD, FN-T score, and tibial cortical density to mortality remained significant but became insignificant when albumin was included in the multivariate analysis. Reduced FN-BMD, FN-T score, and tibial cortical density were significantly associated with an increased risk of death in patients with ESRD. © 2017 S. Karger AG, Basel.

  16. Quantitative trait locus on chromosome X affects bone loss after maturation in mice.

    PubMed

    Okudaira, Shuzo; Shimizu, Motoyuki; Otsuki, Bungo; Nakanishi, Rika; Ohta, Akira; Higuchi, Keiichi; Hosokawa, Masanori; Tsuboyama, Tadao; Nakamura, Takashi

    2010-09-01

    Genetic programming is known to affect the peak bone mass and bone loss after maturation. However, little is known about how polymorphic genes on chromosome X (Chr X) modulate bone loss after maturation. We previously reported a quantitative trait locus (QTL) on Chr X, designated Pbd3, which had a suggestive linkage to bone mass, in male SAMP2 and SAMP6 mice. In this study, we aimed to clarify the effects of Pbd3 on the skeletal phenotype. We generated a congenic strain, P2.P6-X, carrying a 45.6-cM SAMP6-derived Chr X interval on a SAMP2 genetic background. The effects of Pbd3 on the bone phenotype were determined by microcomputed tomography (microCT), whole-body dual-energy X-ray absorptiometry (DXA), serum bone turnover markers, and histomorphometric parameters. Both the bone area fraction (BA/TA) on microCT and whole-body DXA revealed reduced bone loss in P2.P6-X compared with that in SAMP2. The serum concentrations of bone turnover markers at 4 months of age were significantly lower in P2.P6-X than in SAMP2, but did not differ at 8 months of age. These results were observed in female mice, but not in male mice. In conclusion, a QTL within a segregated 45.6-cM interval on Chr X is sex-specifically related to the rate of bone loss after maturation.

  17. Measurement of bone mineral density in the tunnel regions for anterior cruciate ligament reconstruction by dual-energy X-ray absorptiometry, computed tomography scan, and the immersion technique based on Archimedes' principle.

    PubMed

    Tie, Kai; Wang, Hua; Wang, Xin; Chen, Liaobin

    2012-10-01

    To determine, for anterior cruciate ligament (ACL) reconstruction, whether the bone mineral density (BMD) of the femoral tunnel was higher than that of the tibial tunnel, to provide objective evidence for choosing the appropriate diameter of interference screws. Two groups were enrolled. One group comprised 30 normal volunteers, and the other comprised 9 patients with ACL rupture. Dual-energy X-ray absorptiometry was used to measure the BMD of the femoral and tibial tunnel regions of the volunteers' right knees by choosing a circular area covering the screw fixation region. The knees were also scanned by spiral computed tomography (CT), and the 3-dimensional reconstruction technique was used to determine the circular sections passing through the longitudinal axis of the femoral and tibial tunnels. Grayscale CT values of the cross-sectional area were measured. Cylindrical cancellous bone blocks were removed from the femoral and tibial tunnels during the ACL reconstruction for the patients. The volumetric BMD of the bone blocks was measured using a standardized immersion technique according to Archimedes' principle. As measured by dual-energy X-ray absorptiometry, the BMD of the femoral and tibial tunnel regions was 1.162 ± 0.034 g/cm(2) and 0.814 ± 0.038 g/cm(2), respectively (P < .01). The CT value of the femoral tunnel region was 211.7 ± 11.5 Hounsfield units, and the value of the tibial tunnel region was 104.9 ± 7.4 Hounsfield units (P < .01). The volumetric BMD of the bone block from the femoral tunnel (2.80 ± 0.88 g/cm(3)) was higher than the value from the tibial tunnel (1.88 ± 0.59 g/cm(3)) (P < .01). Comparing the data between male and female patients, we found no significant difference in both femoral and tibial tunnel regions. For ACL reconstruction, the BMD of the femoral tunnel is higher than that of the tibial tunnel. This implies that a proportionally larger-diameter interference screw should be used for fixation in the proximal tibia than that

  18. Comparison of Body Composition Assessed by Dual-Energy X-Ray Absorptiometry and BMI in Current and Former U.S. Navy Service Members

    PubMed Central

    Gasier, Heath G.; Hughes, Linda M.; Young, Colin R.; Richardson, Annely M.

    2015-01-01

    Background Little is known of the diagnostic accuracy of BMI in classifying obesity in active duty military personnel and those that previously served. Thus, the primary objectives were to determine the relationship between lean and fat mass, and body fat percentage (BF%) with BMI, and assess the agreement between BMI and BF% in defining obesity. Methods Body composition was measured by dual-energy X-ray absorptiometry in 462 males (20–91 years old) who currently or previously served in the U.S. Navy. A BMI of ≥ 30 kg/m2 and a BF% ≥ 25% were used for obesity classification. Results The mean BMI (± SD) and BF% were 28.8 ± 4.1 and 28.9 ± 6.6%, respectively, with BF% increasing with age. Lean mass, fat mass, and BF% were significantly correlated with BMI for all age groups. The exact agreement of obesity defined by BMI and BF% was fair (61%), however, 38% were misclassified by a BMI cut-off of 30 when obesity was defined by BF%. Conclusions From this data we determined that there is a good correlation between body composition and BMI, and fair agreement between BMI and BF% in classifying obesity in a group of current and former U.S. Navy service members. However, as observed in the general population, a significant proportion of individuals with excess fat are misclassified by BMI cutoffs. PMID:26197480

  19. Impact of beverage consumption, age, and site dependency on dual energy X-ray absorptiometry (DEXA) measurements in perimenopausal women: a prospective study.

    PubMed

    Lo, Huan-Chu; Kuo, Duen-Pang; Chen, Yen-Lin

    2017-08-01

    The aim of this study was to determine the best site for bone mineral density (BMD) measurements based on T -scores, age, and beverage consumption. In this prospective study, 271 women stratified by age (average age: 61.9 years) underwent dual energy X-ray absorptiometry (DEXA) scanning of their lumbar spine, hips, and forearms. Osteoporosis was defined as a BMD of 2.5 standard deviations or more below the mean peak bone mass based on a reference population of adult women (translated as a T -score ≤ -2.5), as measured by DEXA. Participants were also evaluated regarding alcohol and caffeine consumption by a semiquantitative questionnaire. A significant discrepancy was observed in the classification of osteoporosis at different locations, with hip and forearm showing the best correlation (Pearson's r = 0.627, p < 0.001). In addition, for participants over 50 years of age, hip and forearm showed the best correlation. Significant correlations were also noted between forearm T -scores and caffeine consumed and, to a lesser extent, the level of alcohol consumption. In the group ≤ 50 years of age, lumbar spine and forearm T -scores were only associated with alcohol consumption. In the group over 50 years of age, hip and forearm T -scores were only associated with caffeine consumption. Bone mineral density measurements at the hip and forearm correlated with caffeine consumption in elderly Taiwanese women. This is an important finding since age and caffeine consumption are known risk factors for osteoporosis.

  20. X-ray filter for x-ray powder diffraction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sinsheimer, John Jay; Conley, Raymond P.; Bouet, Nathalie C. D.

    Technologies are described for apparatus, methods and systems effective for filtering. The filters may comprise a first plate. The first plate may include an x-ray absorbing material and walls defining first slits. The first slits may include arc shaped openings through the first plate. The walls of the first plate may be configured to absorb at least some of first x-rays when the first x-rays are incident on the x-ray absorbing material, and to output second x-rays. The filters may comprise a second plate spaced from the first plate. The second plate may include the x-ray absorbing material and wallsmore » defining second slits. The second slits may include arc shaped openings through the second plate. The walls of the second plate may be configured to absorb at least some of second x-rays and to output third x-rays.« less

  1. Disorders of bone and bone mineral metabolism.

    PubMed

    Komoroski, Monica; Azad, Nasrin; Camacho, Pauline

    2014-01-01

    Metabolic bone disorders are very common in the general population and untreated, they can cause a variety of neurologic symptoms. These diseases include osteoporosis, vitamin D deficiency, Paget's disease, and alterations in calcium, phosphorus, and magnesium metabolism. Diagnosis is made through analysis of metabolic bone blood chemistries as well as radiologic studies such as dual energy X-ray absorptiometry (DXA) scans, bone scans, and X-rays. Treatment options have advanced significantly in the past decade for osteoporosis and Paget's disease and mainly include antiresorptive therapy. New recommendations for treatment of primary hyperparathyroidism are discussed as well as therapy for calcium, phosphorus, and mineral disorders. © 2014 Elsevier B.V. All rights reserved.

  2. Estimating abdominal adipose tissue with DXA and anthropometry.

    PubMed

    Hill, Alison M; LaForgia, Joe; Coates, Alison M; Buckley, Jonathan D; Howe, Peter R C

    2007-02-01

    To identify an anatomically defined region of interest (ROI) from DXA assessment of body composition that when combined with anthropometry can be used to accurately predict intra-abdominal adipose tissue (IAAT) in overweight/obese individuals. Forty-one postmenopausal women (age, 49 to 66 years; BMI, 26 to 37 kg/m(2)) underwent anthropometric and body composition assessments. ROI were defined as quadrilateral boxes extending 5 or 10 cm above the iliac crest and laterally to the edges of the abdominal soft tissue. A single-slice computed tomography (CT) scan was measured at the L3 to L4 intervertebral space, and abdominal skinfolds were taken. Forward step-wise regression revealed the best predictor model of IAAT area measured by CT (r(2) = 0.68, standard error of estimate = 17%) to be: IAAT area (centimeters squared) = 51.844 + DXA 10-cm ROI (grams) (0.031) + abdominal skinfold (millimeters) (1.342). Interobserver reliability for fat mass (r = 0.994; coefficient of variation, 2.60%) and lean mass (r = 0.986, coefficient of variation, 2.67%) in the DXA 10-cm ROI was excellent. This study has identified a DXA ROI that can be reliably measured using prominent anatomical landmarks, in this case, the iliac crest. Using this ROI, combined with an abdominal skinfold measurement, we have derived an equation to predict IAAT in overweight/obese postmenopausal women. This approach offers a simpler, safer, and more cost-effective method than CT for assessing the efficacy of lifestyle interventions aimed at reducing IAAT. However, this warrants further investigation and validation with an independent cohort.

  3. Soft X-ray observations of Centaurus X-3 from Copernicus

    NASA Technical Reports Server (NTRS)

    Margon, B.; Mason, K. O.; Hawkins, F. J.; Sanford, P. W.

    1975-01-01

    We have detected soft X-ray emission from Centaurus X-3 in the 0.6-1.9 keV band, using the focusing telescope aboard OAO Copernicus. The flux is compatible with an extrapolation of the harder X-ray spectrum, attenuated by (3-4) times 10 to the 22nd atoms per sq cm of interstellar and/or circumstellar matter. The data are consistent with the distance estimate of 5-10 kpc derived from the spectroscopic modulus of the optical component, and obviate the need to postulate the primary to be an anomalously subluminous hot star. There is currently no compelling evidence that such models must be invoked to explain any of the observed compact X-ray sources.

  4. INTEGRAL hard X-ray spectra of the cosmic X-ray background and Galactic ridge emission

    NASA Astrophysics Data System (ADS)

    Türler, M.; Chernyakova, M.; Courvoisier, T. J.-L.; Lubiński, P.; Neronov, A.; Produit, N.; Walter, R.

    2010-03-01

    Aims: We derive the spectra of the cosmic X-ray background (CXB) and of the Galactic ridge X-ray emission (GRXE) in the ~20-200 keV range from the data of the IBIS instrument aboard the INTEGRAL satellite obtained during the four dedicated Earth-occultation observations in early 2006. Methods: We analyze the modulation of the IBIS/ISGRI detector counts induced by the passage of the Earth through the field of view of the instrument. Unlike previous studies, we do not fix the spectral shape of the various contributions, but model instead their spatial distribution and derive for each of them the expected modulation of the detector counts. The spectra of the diffuse emission components are obtained by fitting the normalizations of the model lightcurves to the observed modulation in different energy bins. Because of degeneracy, we guide the fits with a realistic choice of the input parameters and a constraint for spectral smoothness. Results: The obtained CXB spectrum is consistent with the historic HEAO-1 results and falls slightly below the spectrum derived with Swift/BAT. A 10% higher normalization of the CXB cannot be completely excluded, but it would imply an unrealistically high albedo of the Earth. The derived spectrum of the GRXE confirms the presence of a minimum around 80 keV with improved statistics and yields an estimate of ~0.6 M⊙ for the average mass of white dwarfs in the Galaxy. The analysis also provides updated normalizations for the spectra of the Earth's albedo and the cosmic-ray induced atmospheric emission. Conclusions: This study demonstrates the potential of INTEGRAL Earth-occultation observations to derive the hard X-ray spectra of three fundamental components: the CXB, the GRXE and the Earth emission. Further observations would be extremely valuable to confirm our results with improved statistics.

  5. Estimating body fat in NCAA Division I female athletes: a five-compartment model validation of laboratory methods.

    PubMed

    Moon, Jordan R; Eckerson, Joan M; Tobkin, Sarah E; Smith, Abbie E; Lockwood, Christopher M; Walter, Ashley A; Cramer, Joel T; Beck, Travis W; Stout, Jeffrey R

    2009-01-01

    The purpose of the present study was to determine the validity of various laboratory methods for estimating percent body fat (%fat) in NCAA Division I college female athletes (n = 29; 20 +/- 1 year). Body composition was assessed via hydrostatic weighing (HW), air displacement plethysmography (ADP), and dual-energy X-ray absorptiometry (DXA), and estimates of %fat derived using 4-compartment (C), 3C, and 2C models were compared to a criterion 5C model that included bone mineral content, body volume (BV), total body water, and soft tissue mineral. The Wang-4C and the Siri-3C models produced nearly identical values compared to the 5C model (r > 0.99, total error (TE) < 0.40%fat). For the remaining laboratory methods, constant error values (CE) ranged from -0.04%fat (HW-Siri) to -3.71%fat (DXA); r values ranged from 0.89 (ADP-Siri, ADP-Brozek) to 0.93 (DXA); standard error of estimate values ranged from 1.78%fat (DXA) to 2.19%fat (ADP-Siri, ADP-Brozek); and TE values ranged from 2.22%fat (HW-Brozek) to 4.90%fat (DXA). The limits of agreement for DXA (-10.10 to 2.68%fat) were the largest with a significant trend of -0.43 (P < 0.05). With the exception of DXA, all of the equations resulted in acceptable TE values (<3.08%fat). However, the results for individual estimates of %fat using the Brozek equation indicated that the 2C models that derived BV from ADP and HW overestimated (5.38, 3.65%) and underestimated (5.19, 4.88%) %fat, respectively. The acceptable TE values for both HW and ADP suggest that these methods are valid for estimating %fat in college female athletes; however, the Wang-4C and Siri-3C models should be used to identify individual estimates of %fat in this population.

  6. Food prices and body fatness among youths.

    PubMed

    Grossman, Michael; Tekin, Erdal; Wada, Roy

    2014-01-01

    We examine the effect of food prices on clinical measures of obesity, including body mass index (BMI) and percentage body fat (PBF) measures derived from bioelectrical impedance analysis (BIA) and dual energy X-ray absorptiometry (DXA), among youths ages 12 through 18 in the National Health and Nutrition Examination Survey. This is the first study to consider clinically measured levels of body composition rather than BMI to investigate the effects of food prices on obesity outcomes among youths classified by gender and race/ethnicity. Our findings suggest that increases in the real price per calorie of food for home consumption and the real price of fast-food restaurant food lead to improvements in obesity outcomes among youths. We also find that a rise in the real price of fruits and vegetables leads to increased obesity. Finally, our results indicate that measures of PBF derived from BIA and DXA are no less sensitive and in some cases more sensitive to the prices just mentioned than BMI, and serve an important role in demonstrating that rising food prices (except fruit and vegetable prices) are indeed associated with reductions in obesity rather than with reductions in body size proportions alone. Copyright © 2013 Elsevier B.V. All rights reserved.

  7. Einstein X-ray survey of the Pleiades - The dependence of X-ray emission on stellar age

    NASA Technical Reports Server (NTRS)

    Micela, G.; Sciortino, S.; Serio, S.; Vaiana, G. S.; Bookbinder, J.; Golub, L.; Harnden, F. R., Jr.; Rosner, R.

    1985-01-01

    The data obtained with two pointed observations of 1 deg by 1 deg fields of the Pleiades region have been analyzed, and the results are presented. The maximum-likelihood X-ray luminosity functions for the Pleiades G and K stars in the cluster are derived, and it is shown that, for the G stars, the Pleiades X-ray luminosity function is significantly brighter than the corresponding function for Hyades G dwarf stars. This finding indicates a dependence of X-ray luminosity on stellar age, which is confirmed by comparison of the same data with median X-ray luminosities of pre-main sequence and local disk population dwarf G stars. It is suggested that the significantly larger number of bright X-ray sources associated with G stars than with K stars, the lack of detection of M stars, and the relatively rapid rotation of the Pleiades K stars can be explained in terms of the onset of internal differential rotation near the convective envelope-radidative core interface after the spin-up phase during evolution to the main sequence.

  8. Effect of Exercise and Antidepressants on Skeletal Outcomes in Adolescent Girls With Anorexia Nervosa.

    PubMed

    DiVasta, Amy D; Feldman, Henry A; O'Donnell, Jennifer M; Long, Jin; Leonard, Mary B; Gordon, Catherine M

    2017-02-01

    We examined the relationships between malnutrition, lifestyle factors, and bone health in anorexia nervosa (AN) via dual-energy X-ray absorptiometry (DXA) and peripheral quantitative computed tomography (pQCT). Seventy adolescent girls with AN and 132 normal-weighted controls underwent pQCT tibial measures including trabecular volumetric bone mineral density (vBMD), cortical vBMD, and cortical thickness. Participants with AN underwent DXA measures of the axial skeleton. We assessed the association of DXA and pQCT measures with clinical and lifestyle variables. Body mass index Z-score and ideal body weight percentage were positively correlated with trabecular vBMD, cortical CSA, and section modulus (p < .04). Exercise was associated with all pQCT measures but only with hip BMD by DXA. In AN, the use of antidepressants was associated with lower pQCT measures (p < .03). Antidepressants may negatively, and exercise positively, influence BMD in adolescents with eating disorders. These findings offer a provocative look at two longstanding questions. Copyright © 2016 Society for Adolescent Health and Medicine. Published by Elsevier Inc. All rights reserved.

  9. Clinical Imaging of Bone Microarchitecture with HR-pQCT

    PubMed Central

    Nishiyama, Kyle K.; Shane, Elizabeth

    2014-01-01

    Osteoporosis, a disease characterized by loss of bone mass and structural deterioration, is currently diagnosed by dual-energy x-ray absorptiometry (DXA). However, DXA does not provide information about bone microstructure, which is a key determinant of bone strength. Recent advances in imaging permit the assessment of bone microstructure in vivo using high-resolution peripheral quantitative computed tomography (HR-pQCT). From these data, novel image processing techniques can be applied to characterize bone quality and strength. To date, most HR-pQCT studies are cross-sectional comparing subjects with and without fracture. These studies have shown that HR-pQCT is capable of discriminating fracture status independent of DXA. Recent longitudinal studies present new challenges in terms of analyzing the same region of interest and multisite calibrations. Careful application of analysis techniques and educated clinical interpretation of HR-pQCT results have improved our understanding of various bone-related diseases and will no doubt continue to do so in the future. PMID:23504496

  10. Severity of aortic calcification is positively associated with vertebral fracture in older men—a densitometry study in the STRAMBO cohort

    PubMed Central

    Samelson, E. J.; Sornay-Rendu, E.; Chapurlat, R.; Kiel, D. P.

    2013-01-01

    Summary In older men, severe abdominal aortic calcification and vertebral fracture (both assessed using dual-energy X-ray absorptiometry) were positively associated after adjustment for confounders including bone mineral density. Introduction Abdominal aortic calcification (AAC) is associated with higher fracture risk, independently of low bone mineral density (BMD). Dual-energy X-ray absorptiometry (DXA) can be used to assess both vertebral fracture and AAC and requires less time, cost, and radiation exposure. Methods We conducted a cross-sectional study of the association between AAC and prevalent vertebral fractures in 901 men ≥50 years old. We used DXA (vertebral fracture assessment) to evaluate BMD, vertebral fracture, and AAC. Results Prevalence of vertebral fracture was 11 %. Median AAC score was 1 and 12 % of men had AAC score >6. After adjustment for age, weight, femoral neck BMD, smoking, ischemic heart disease, diabetes, and hypertension, AAC score >6 (vs ≤6) was associated with 2.5 (95 % CI, 1.4–4.5) higher odds of vertebral fracture. Odds of vertebral fracture for AAC score >6 increased with vertebral fracture severity (grade 1, OR=1.8; grade 2, OR=2.4; grade 3, OR=4.4; trend p<0.01) and with the number of vertebral fractures (1 fracture, OR=2.0, >1 fracture, OR=3.5). Prevalence of vertebral fracture was twice as high in men having both a T-score<−2.0 and an AAC score>6 compared with men having only one of these characteristics. Conclusions Men with greater severity AAC had greater severity and greater number of vertebral fractures, independently of BMD and co-morbidities. DXA can be used to assess vertebral fracture and AAC. It can provide a rapid, safe, and less expensive alternative to radiography. DXA may be an important clinical tool to identify men at high risk of adverse outcomes from osteoporosis and cardiovascular disease. PMID:22872071

  11. Binary model of Circinus X-1. I - Eccentricity from combined X-ray and radio observations

    NASA Technical Reports Server (NTRS)

    Murdin, P.; Jauncey, D. L.; Lerche, I.; Nicolson, G. D.; Kaluzienski, L. J.; Holt, S. S.; Haynes, R. F.

    1980-01-01

    A binary star model is used to account for the 16.59-d flaring behavior of the X-ray emission from Circinus X-1. The orbital eccentricity of 0.8 + or - 0.1 is derived from the X-ray light curve by assuming that the sharp X-ray cut-off every 16.59-d is a result of bound-free absorption in the primary star's stellar wind. The shape of the light curve has changed over the last eight years, and this is interpreted as due to orbital precession of the binary system. Simultaneous radio and X-ray observations of the flare from Circinus X-1 on February 1-5, 1978 are reported. These are accounted for within the framework of the model. The radio observations at 5 GHz are used independently to derive a high value of the orbital eccentricity (e = 0.7).

  12. Accretion torques in X-ray pulsars

    NASA Technical Reports Server (NTRS)

    Rappaport, S.; Joss, P. C.

    1977-01-01

    An analysis of the accretion process in an X-ray pulsar, whereby angular momentum is transferred to the star and its rotation period is changed, is presented, and an expression for the fractional rate of change of the pulse period in terms of X-ray luminosity and other star parameters is derived. It is shown that observed characteristic spin-up time scales for seven X-ray pulsars strongly support the view that in every source (1) the pulse period reflects the rotation period of a compact object, (2) the accretion is mediated by a disk surrounding the compact object and rotating in the same sense, and (3) the compact object is a neutron star rather than a white dwarf.

  13. Pump–probe spectrometer for measuring x-ray induced strain

    DOE PAGES

    Loether, A.; Adams, B. W.; DiCharia, A.; ...

    2016-04-20

    A hard x-ray pump–probe spectrometer using a multi-crystal Bragg reflector is demonstrated at a third generation synchrotron source. This device derives both broadband pump and monochromatic probe pulses directly from a single intense, broadband x-ray pulse centered at 8.767 keV. In conclusion, we present a proof-of-concept experiment which directly measures x-ray induced crystalline lattice strain.

  14. TEMPORAL AND SPATIAL ANALYSES OF SPECTRAL INDICES OF NONTHERMAL EMISSIONS DERIVED FROM HARD X-RAYS AND MICROWAVES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Asai, Ayumi; Kiyohara, Junko; Takasaki, Hiroyuki

    2013-02-15

    We studied electron spectral indices of nonthermal emissions seen in hard X-rays (HXRs) and microwaves. We analyzed 12 flares observed by the Hard X-Ray Telescope aboard Yohkoh, Nobeyama Radio Polarimeters, and the Nobeyama Radioheliograph (NoRH), and compared the spectral indices derived from total fluxes of HXRs and microwaves. Except for four events, which have very soft HXR spectra suffering from the thermal component, these flares show a gap {Delta}{delta} between the electron spectral indices derived from HXRs {delta} {sub X} and those from microwaves {delta}{sub {mu}} ({Delta}{delta} = {delta} {sub X} - {delta}{sub {mu}}) of about 1.6. Furthermore, from themore » start to the peak times of the HXR bursts, the time profiles of the HXR spectral index {delta} {sub X} evolve synchronously with those of the microwave spectral index {delta}{sub {mu}}, keeping the constant gap. We also examined the spatially resolved distribution of the microwave spectral index by using NoRH data. The microwave spectral index {delta}{sub {mu}} tends to be larger, which means a softer spectrum, at HXR footpoint sources with stronger magnetic field than that at the loop tops. These results suggest that the electron spectra are bent at around several hundreds of keV, and become harder at the higher energy range that contributes the microwave gyrosynchrotron emission.« less

  15. The SWIFT Gamma-Ray Burst X-Ray Telescope

    NASA Technical Reports Server (NTRS)

    Hill, J. E.; Burrows, D. N.; Nousek, J. A.; Wells, A.; Chincarini, G.; Abbey, A. F.; Angelini, L.; Beardmore, A.; Brauninger, H. W.; Chang, W.

    2006-01-01

    The Swift Gamma-Ray Burst Explorer is designed to make prompt multi-wavelength observations of Gamma-Ray Bursts and GRB afterglows. The X-ray Telescope enables Swift to determine GRB positions with a few arcseconds accuracy within 100 seconds of the burst onset. The XRT utilizes a mirror set built for JET-X and an XMM-Newton/ EPIC MOS CCD detector to provide a sensitive broad-band (0.2-10 keV) X-ray imager with an effective area of more than 120 sq cm at 1.5 keV, a field of view of 23.6 x 23.6 arcminutes, and an angular resolution of 18 arcseconds (HPD). The detection sensitivity is 2x10(exp 14) erg/sq cm/s in 10(exp 4) seconds. The instrument provides automated source detection and position reporting within 5 seconds of target acquisition. It can also measure the redshifts of GRBs with Iron line emission or other spectral features. The XRT operates in an auto-exposure mode, adjusting the CCD readout mode automatically to optimize the science return as the source intensity fades. The XRT measures spectra and lightcurves of the GRB afterglow beginning about a minute after the burst and follows each burst for days or weeks. We provide an overview of the X-ray Telescope scientific background from which the systems engineering requirements were derived, with specific emphasis on the design and qualification aspects from conception through to launch. We describe the impact on cleanliness and vacuum requirements for the instrument low energy response and to maintain the high sensitivity to the fading signal of the Gamma-ray Bursts.

  16. X-Ray Emission from Compact Sources

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cominsky, L

    2004-03-23

    This paper presents a review of the physical parameters of neutron stars and black holes that have been derived from X-ray observations. I then explain how these physical parameters can be used to learn about the extreme conditions occurring in regions of strong gravity, and present some recent evidence for relativistic effects seen in these systems. A glossary of commonly used terms and a short tutorial on the names of X-ray sources are also included.

  17. Start of Eta Car's X-ray Minimum

    NASA Technical Reports Server (NTRS)

    Corcoran, Michael F.; Liburd, Jamar; Hamaguchi, Kenji; Gull, Theodore; Madura, Thomas; Teodoro, Mairan; Moffat, Anthony; Richardson, Noel; Russell, Chris; Pollock, Andrew; hide

    2014-01-01

    Analysis of Eta Car's X-ray spectrum in the 2-10 keV band using quicklook data from the XRay Telescope on Swift shows that the flux on July 30, 2014 was 4.9 plus or minus 2.0×10(exp-12) ergs s(exp-1)cm(exp-2). This flux is nearly equal to the X-ray minimum flux seen by RXTE in 2009, 2003.5, and 1998, and indicates that Eta Car has reached its X-ray minimum, as expected based on the 2024-day period derived from previous 2-10 keV observations with RXTE.

  18. X-Rays

    MedlinePlus

    X-rays are a type of radiation called electromagnetic waves. X-ray imaging creates pictures of the inside of ... different amounts of radiation. Calcium in bones absorbs x-rays the most, so bones look white. Fat ...

  19. X-ray free electron laser: opportunities for drug discovery.

    PubMed

    Cheng, Robert K Y; Abela, Rafael; Hennig, Michael

    2017-11-08

    Past decades have shown the impact of structural information derived from complexes of drug candidates with their protein targets to facilitate the discovery of safe and effective medicines. Despite recent developments in single particle cryo-electron microscopy, X-ray crystallography has been the main method to derive structural information. The unique properties of X-ray free electron laser (XFEL) with unmet peak brilliance and beam focus allow X-ray diffraction data recording and successful structure determination from smaller and weaker diffracting crystals shortening timelines in crystal optimization. To further capitalize on the XFEL advantage, innovations in crystal sample delivery for the X-ray experiment, data collection and processing methods are required. This development was a key contributor to serial crystallography allowing structure determination at room temperature yielding physiologically more relevant structures. Adding the time resolution provided by the femtosecond X-ray pulse will enable monitoring and capturing of dynamic processes of ligand binding and associated conformational changes with great impact to the design of candidate drug compounds. © 2017 The Author(s). Published by Portland Press Limited on behalf of the Biochemical Society.

  20. Hartman Testing of X-Ray Telescopes

    NASA Technical Reports Server (NTRS)

    Saha, Timo T.; Biskasch, Michael; Zhang, William W.

    2013-01-01

    Hartmann testing of x-ray telescopes is a simple test method to retrieve and analyze alignment errors and low-order circumferential errors of x-ray telescopes and their components. A narrow slit is scanned along the circumference of the telescope in front of the mirror and the centroids of the images are calculated. From the centroid data, alignment errors, radius variation errors, and cone-angle variation errors can be calculated. Mean cone angle, mean radial height (average radius), and the focal length of the telescope can also be estimated if the centroid data is measured at multiple focal plane locations. In this paper we present the basic equations that are used in the analysis process. These equations can be applied to full circumference or segmented x-ray telescopes. We use the Optical Surface Analysis Code (OSAC) to model a segmented x-ray telescope and show that the derived equations and accompanying analysis retrieves the alignment errors and low order circumferential errors accurately.

  1. The development and validation of new equations for estimating body fat percentage among Chinese men and women.

    PubMed

    Liu, Xin; Sun, Qi; Sun, Liang; Zong, Geng; Lu, Ling; Liu, Gang; Rosner, Bernard; Ye, Xingwang; Li, Huaixing; Lin, Xu

    2015-05-14

    Equations based on simple anthropometric measurements to predict body fat percentage (BF%) are lacking in Chinese population with increasing prevalence of obesity and related abnormalities. We aimed to develop and validate BF% equations in two independent population-based samples of Chinese men and women. The equations were developed among 960 Chinese Hans living in Shanghai (age 46.2 (SD 5.3) years; 36.7% male) using a stepwise linear regression and were subsequently validated in 1150 Shanghai residents (58.7 (SD 6.0) years; 41.7% male; 99% Chinese Hans, 1% Chinese minorities). The associations of equation-derived BF% with changes of 6-year cardiometabolic outcomes and incident type 2 diabetes (T2D) were evaluated in a sub-cohort of 780 Chinese, compared with BF% measured by dual-energy X-ray absorptiometry (DXA; BF%-DXA). Sex-specific equations were established with age, BMI and waist circumference as independent variables. The BF% calculated using new sex-specific equations (BF%-CSS) were in reasonable agreement with BF%-DXA (mean difference: 0.08 (2 SD 6.64) %, P= 0.606 in men; 0.45 (2 SD 6.88) %, P< 0.001 in women). In multivariate-adjusted models, the BF%-CSS and BF%-DXA showed comparable associations with 6-year changes in TAG, HDL-cholesterol, diastolic blood pressure, C-reactive protein and uric acid (P for comparisons ≥ 0.05). Meanwhile, the BF%-CSS and BF%-DXA had comparable areas under the receiver operating characteristic curves for associations with incident T2D (men P= 0.327; women P= 0.159). The BF% equations might be used as surrogates for DXA to estimate BF% among adult Chinese. More studies are needed to evaluate the application of our equations in different populations.

  2. Cross-correlation of the X-ray background with nearby galaxies

    NASA Technical Reports Server (NTRS)

    Jahoda, Keith; Mushotzky, Richard F.; Boldt, Elihu; Lahav, Ofer

    1991-01-01

    The detection of a signal in the cross-correlation of the diffuse 2-10 keV HEAO 1 A-2 X-ray surface brightness with the galaxy surface density derived from diameter-limited samples from the Uppsala General Catalogue is reported. An ad hoc relationship between the X-ray flux and the galaxy counts is used to estimate the local X-ray volume emissivity at 2.8 + or - 1.0 x 10 to the 38th ergs/s/cu Mpc. This result implies that unevolved populations of X-ray sources correlated with present-epoch galaxies can contribute only 13 + or - 5 percent of the cosmic X-ray background.

  3. Application of X-ray imaging techniques to auroral monitoring

    NASA Technical Reports Server (NTRS)

    Rust, D. M.; Burstein, P.

    1981-01-01

    The precipitation of energetic particles into the ionosphere produces bremsstrahlung X-rays and K-alpha line emission from excited oxygen and nitrogen. If viewed from a spacecraft in a highly elliptical polar orbit, this soft (0.3 - 3.0 keV) X-radiation will provide an almost uninterrupted record of dayside and nightside auroras. A grazing incidence X-ray telescope especially designed for such auroral monitoring is described. High photon collection efficiency will permit exposure times of approximately 100 seconds during substorms. Spectrophotometry will allow users to derive the energy spectrum of the precipitating particles. If placed in a 15 earth-radius orbit, the telescope can produce auroral X-ray images with 30 km resolution. Absolute position of X-ray auroras can be established with a small optical telescope co-aligned with the X-ray telescope. Comparison of X-ray and optical images will establish the height and global distribution of X-ray aurorae, relative to well-known optical auroras, thus melding the new X-ray results with knowledge of optical auroras.

  4. SEARCH FOR GAMMA-RAY EMISSION FROM X-RAY-SELECTED SEYFERT GALAXIES WITH FERMI-LAT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ackermann, M.; Ajello, M.; Allafort, A.

    We report on a systematic investigation of the {gamma}-ray properties of 120 hard X-ray-selected Seyfert galaxies classified as 'radio-quiet' objects, utilizing the three-year accumulation of Fermi Large Area Telescope (LAT) data. Our sample of Seyfert galaxies is selected using the Swift Burst Alert Telescope 58 month catalog, restricting the analysis to the bright sources with average hard X-ray fluxes F{sub 14-195keV} {>=} 2.5 Multiplication-Sign 10{sup -11} erg cm{sup -2} s{sup -1} at high Galactic latitudes (|b| > 10 Degree-Sign ). In order to remove 'radio-loud' objects from the sample, we use the 'hard X-ray radio loudness parameter', R{sub rX}, definedmore » as the ratio of the total 1.4 GHz radio to 14-195 keV hard X-ray energy fluxes. Among 120 X-ray bright Seyfert galaxies with R{sub rX} <10{sup -4}, we did not find a statistically significant {gamma}-ray excess (TS > 25) positionally coincident with any target Seyferts, with possible exceptions of ESO 323-G077 and NGC 6814. The mean value of the 95% confidence level {gamma}-ray upper limit for the integrated photon flux above 100 MeV from the analyzed Seyferts is {approx_equal} 4 Multiplication-Sign 10{sup -9} photons cm{sup -2} s{sup -1} , and the upper limits derived for several objects reach {approx_equal} 1 Multiplication-Sign 10{sup -9} photons cm{sup -2} s{sup -1} . Our results indicate that no prominent {gamma}-ray emission component related to active galactic nucleus activity is present in the spectra of Seyferts around GeV energies. The Fermi-LAT upper limits derived for our sample probe the ratio of {gamma}-ray to X-ray luminosities L{sub {gamma}}/L{sub X} < 0.1, and even <0.01 in some cases. The obtained results impose novel constraints on the models for high-energy radiation of 'radio-quiet' Seyfert galaxies.« less

  5. Complete Hard X-Ray Surveys, AGN Luminosity Functions and the X-Ray Background

    NASA Technical Reports Server (NTRS)

    Tueller, Jack

    2011-01-01

    AGN are believed to make up most of the Cosmic X-Ray Background (CXB) above a few keV, but this background cannot be fully resolved at energies less than 10 keV due to absorption. The Swift/BAT and INTEGRAL missions are performing the first complete hard x-ray surveys with minimal bias due to absorption. The most recent results for both missions will be presented. Although the fraction of the CXB resolved by these surveys is small, it is possible to derive unbiased number counts and luminosity functions for AGN in the local universe. The survey energy range from 15-150 keV contains the important reflection and cutoff spectral features dominate the shape of the AGN contribution to the CXB. Average spectral characteristics of survey detected AGN will be presented and compared with model distributions. The numbers of hard x-ray blazars detected in these surveys are finally sufficient to estimate this important component's contribution the cosmic background. Constraints on CXB models and their significance will be discussed.

  6. Search For Gamma-Ray Emission From X-Ray-Selected Seyfert Galaxies With Fermi -LAT

    DOE PAGES

    Ackermann, M.

    2012-02-23

    We report on a systematic investigation of the γ-ray properties of 120 hard Xray– selected Seyfert galaxies classified as ‘radio-quiet’ objects, utilizing the threeyear accumulation of Fermi–LAT data. Our sample of Seyfert galaxies is selected using the Swift–BAT 58-month catalog, restricting the analysis to the bright sources with average hard X-ray fluxes F14-195 keV ≥ 2.5 × 10 -11 erg cm -2 s -1 at high Galactic latitudes (|b| > 10°). In order to remove ‘radio-loud’ objects from the sample, we use the ‘hard X-ray radio loudness parameter’, RrX , defined as the ratio of the total 1.4 GHz radiomore » to 14 - 195 keV hard X-ray energy fluxes. Among 120 X-ray bright Seyfert galaxies with RrX < 10-4, we did not find a statistically significant γ-ray excess (TS > 25) positionally coincident with any target Seyferts, with possible exceptions of ESO 323–G077 and NGC 6814. The mean value of the 95% confidence level γ-ray upper limit for the integrated photon flux above 100 MeV from the analyzed Seyferts is ≃ 4×10 -9 ph cm -2 s -1 , and the upper limits derived for several objects reach ≃ 1 × 10 -9 ph cm -2 s -1 . Our results indicate that no prominent γ-ray emission component related to active galactic nucleus activity is present in the spectra of Seyferts around GeV energies. The Fermi–LAT upper limits derived for our sample probe the ratio of γ-ray to X-ray luminosities L /LX < 0.1, and even < 0.01 in some cases. The obtained results impose novel constraints on the models for high energy radiation of ‘radio-quiet’ Seyfert galaxies.« less

  7. Visceral fat measured by DXA is associated with increased risk of non-spine fractures in nonobese elderly women: a population-based prospective cohort analysis from the São Paulo Ageing & Health (SPAH) Study.

    PubMed

    Machado, L G; Domiciano, D S; Figueiredo, C P; Caparbo, V F; Takayama, L; Oliveira, R M; Lopes, J B; Menezes, P R; Pereira, R M R

    2016-12-01

    The present study investigates the relationship between visceral fat measured by dual-energy X-ray absorptiometry (DXA) and the incidence of non-spine fractures in community-dwelling elderly women. We demonstrated a potential negative effect of visceral fat on bone health in nonobese women. The protective effect of obesity on bone health has been questioned because visceral fat has been demonstrated to have a deleterious effect on bone. The aim of this study was to investigate the association of visceral fat measured by DXA with the incidence of non-spine fractures in community-dwelling elderly women. This longitudinal prospective population-based cohort study evaluated 433 community-dwelling women aged 65 years or older. A specific clinical questionnaire, including personal history of a fragility fracture in non-spine osteoporotic sites, was administered at baseline and after an average of 4.3 years. All incidences of fragility fractures during the study period were confirmed by affected-site radiography. Visceral adipose tissue (VAT) was measured in the android region of a whole-body DXA scan. The mean age was 72.8 ± 4.7 years, and 28 incident non-spine osteoporotic fractures were identified after a mean follow-up time of 4.3 ± 0.8 years. According to the Lipschitz classification for nutritional status in the elderly, 38.6 % of women were nonobese (BMI ≤ 27 kg/m 2 ) and 61.4 % were obese/overweight. Logistic regression models were used to estimate the relationship between VAT and non-spine fractures in elderly women. After adjusting for age, race, previous fractures, and BMD, VAT (mass, area, volume) had a significant association with the incidence of non-spine fractures only in nonobese elderly women (VAT mass: OR, 1.42 [95 % CI, 1.09-1.85; p = 0.010]; VAT area: OR, 1.19 [95 % CI, 1.05-1.36; p = 0.008]; VAT volume: OR, 1.40 [95 % CI, 1.09-1.80; p = 0.009]). This study suggests a potential negative effect of visceral

  8. Long-Term X-Ray Variability of Circinus X-1

    NASA Technical Reports Server (NTRS)

    Saz Parkinson, P. M.; Tournear, D. M.; Bloom, E. D.; Focke, W. B.; Reilly, K. T.

    2003-01-01

    We present an analysis of long term X-ray monitoring observations of Circinus X-1 (Cir X-1) made with four different instruments: Vela 5B, Ariel V ASM, Ginga ASM, and RXTE ASM, over the course of more than 30 years. We use Lomb-Scargle periodograms to search for the approx. 16.5 day orbital period of Cir X-1 in each of these data sets and from this derive a new orbital ephemeris based solely on X-ray measurements, which we compare to the previous ephemerides obtained from radio observations. We also use the Phase Dispersion Minimization (PDM) technique, as well as FFT analysis, to verify the periods obtained from periodograms. We obtain dynamic periodograms (both Lomb-Scargle and PDM) of Cir X-1 during the RXTE era, showing the period evolution of Cir X-1, and also displaying some unexplained discrete jumps in the location of the peak power.

  9. Coherent x-ray diffraction

    NASA Astrophysics Data System (ADS)

    Pitney, John Allen

    Conventional x-ray diffraction has historically been done under conditions such that the measured signal consists of an incoherent addition of scattering which is coherent only on a length scale determined by the properties of the beam. The result of the incoherent summation is a statistical averaging over the whole illuminated volume of the sample, which yields certain kinds of information with a high degree of precision and has been key to the success of x-ray diffraction in a variety of applications. Coherent x-ray scattering techniques, such as coherent x-ray diffraction (CXD) and x-ray intensity fluctuation spectroscopy (XIFS), attempt to reduce or eliminate any incoherent averaging so that specific, local structures couple to the measurement without being averaged out. In the case of XIFS, the result is analogous to dynamical light scattering, but with sensitivity to length scales less than 200 nm and time scales from 10-3 s to 103 s. When combined with phase retrieval, CXD represents an imaging technique with the penetration, in situ capabilities, and contrast mechanisms associated with x-rays and with a spatial resolution ultimately limited by the x-ray wavelength. In practice, however, the spatial resolution of CXD imaging is limited by exposure to about 100 A. This thesis describes CXD measurements of the binary alloy Cu3Au and the adaptation of phase retrieval methods for the reconstruction of real-space images of Cu3Au antiphase domains. The theoretical foundations of CXD are described in Chapter 1 as derived from the kinematical formulation for x-ray diffraction and from the temporal and spatial coherence of radiation. The antiphase domain structure of Cu 3Au is described, along with the associated reciprocal-space structure which is measured by CXD. CXD measurements place relatively stringent requirements on the coherence properties of the beam and on the detection mechanism of the experiment; these requirements and the means by which they have been

  10. An extended galactic population of low-luminosity x-ray sources (CVs?) and the diffuse x-ray background

    NASA Technical Reports Server (NTRS)

    Maoz, Eyal; Grindlay, Jonathan E.

    1995-01-01

    The incompatibility of the properties of the X-ray background (XRB) with active galactic nuclei (AGNs) contributing approximately greater than 60% at energies of a few keV has often been interpreted as being due to a substantial contribution of a new population of yet unrecognized X-ray sources. The existence of such population has been recently suggested also by an analysis of very deep ROSAT observations which revealed a considerable excess of faint X-ray sources over that expected from QSO evolution models, and that the average spectrum of the resolved sources becomes harder with decreasing flux limit. These sources could be extragalactic in origin, but if they make a substantial contribution to the XRB then they must exhibit much weaker clustering than galaxies or QSOs in order to be consistent with the stringent constraints on source clustering imposed by autocorrelation analyses of the unresolved XRB. We investigate the possibility that the indicated new population of X-ray sources is Galactic in origin. Examining spherical halo and thick disk distributions, we derive the allowed properties of such populations which would resolve the discrepancy found in the number counts of faint sources and be consistent with observational constraints on the total background intensity, the XRB anisotropy, the number of unidentified bright sources, the Galaxy's total X-ray luminosity, and with the results of fluctuation analyses of the unresolved XRB. We find that a flattened Galactic halo (or a thick disk) distribution with a scale height of a few kpc is consistent with all the above requirements. The typical X-ray luminosity of the sources is approximately equal to 10(exp 30-31)ergs/s in the 0.5-2 keV band, the number density of sources in the solar vicinity is approximately 10(exp -4.5)pc(exp -3), their total number in the Galaxy is approximately 10(exp 8.5), and their total contribution to the Galaxy's X-ray luminosity is approximately 10(exp 39) ergs/s. We discuss the

  11. X-ray beamsplitter

    DOEpatents

    Ceglio, Natale M.; Stearns, Daniel S.; Hawryluk, Andrew M.; Barbee, Jr., Troy W.

    1989-01-01

    An x-ray beamsplitter which splits an x-ray beam into two coherent parts by reflecting and transmitting some fraction of an incident beam has applications for x-ray interferometry, x-ray holography, x-ray beam manipulation, and x-ray laser cavity output couplers. The beamsplitter is formed of a wavelength selective multilayer thin film supported by a very thin x-ray transparent membrane. The beamsplitter resonantly transmits and reflects x-rays through thin film interference effects. A thin film is formed of 5-50 pairs of alternate Mo/Si layers with a period of 20-250 A. The support membrane is 10-200 nm of silicon nitride or boron nitride. The multilayer/support membrane structure is formed across a window in a substrate by first forming the structure on a solid substrate and then forming a window in the substrate to leave a free-standing structure over the window.

  12. Search for Hard X-Ray Emission from the Soft X-Ray Transient Aquila X-1

    NASA Astrophysics Data System (ADS)

    Harmon, B. A.; Zhang, S. N.; Paciesas, W. S.; Tavani, M.; Kaaret, P.; Ford, E.

    1994-12-01

    We are investigating the possibility of hard x-ray emission from the recurrent soft x-ray transient and x-ray burst source Aquila X-1 (Aql X-1). Outbursts of this source are relatively frequent with a spacing of ~ 4-10 months (Kitamoto, S. et al. 1993, ApJ, 403, 315). The recent detections of hard tails (\\(>\\)20 keV) in low luminosity x-ray bursters (Barret, D. & Vedrenne, G. 1994, ApJ Supp. S. 92, 505) suggest that neutron star transient systems such as Aql X-1 can produce hard x-ray emission which is detectable by BATSE. We are correlating reported optical and soft x-ray observations since 1991 of Aql X-1 with BATSE observations in order to search for hard x-ray emission episodes, and to study their temporal and spectral evolution. We will present preliminary results of this search in the 20-1000 keV band using the Earth occultation technique applied to the large area detectors. If this work is successful, we hope to alert the astronomical community for the next Aql X-1 outburst expected in 1995. Simultaneous x-ray/hard x-ray and optical observations of Aql X-1 during outburst would be of great importance for the modeling of soft x-ray transients and related systems.

  13. Monte Carlo derivation of filtered tungsten anode X-ray spectra for dose computation in digital mammography.

    PubMed

    Paixão, Lucas; Oliveira, Bruno Beraldo; Viloria, Carolina; de Oliveira, Marcio Alves; Teixeira, Maria Helena Araújo; Nogueira, Maria do Socorro

    2015-01-01

    Derive filtered tungsten X-ray spectra used in digital mammography systems by means of Monte Carlo simulations. Filtered spectra for rhodium filter were obtained for tube potentials between 26 and 32 kV. The half-value layer (HVL) of simulated filtered spectra were compared with those obtained experimentally with a solid state detector Unfors model 8202031-H Xi R/F & MAM Detector Platinum and 8201023-C Xi Base unit Platinum Plus w mAs in a Hologic Selenia Dimensions system using a direct radiography mode. Calculated HVL values showed good agreement as compared with those obtained experimentally. The greatest relative difference between the Monte Carlo calculated HVL values and experimental HVL values was 4%. The results show that the filtered tungsten anode X-ray spectra and the EGSnrc Monte Carlo code can be used for mean glandular dose determination in mammography.

  14. Retrograde Accretion Discs in High-Mass Be/X-Ray Binaries

    NASA Technical Reports Server (NTRS)

    Christodoulou, D. M.; Laycock, S. G. T.; Kazanas, D.

    2017-01-01

    We have compiled a comprehensive library of all X-ray observations of Magellanic pulsars carried out by XMM-Newton, Chandra and RXTE in the period 1997-2014. In this work, we use the data from 53 high-mass Be/X-ray binaries in the Small Magellanic Cloud to demonstrate that the distribution of spin-period derivatives versus spin periods of spinning-down pulsars is not at all different from that of the accreting spinning-up pulsars. The inescapable conclusion is that the up and down samples were drawn from the same continuous parent population; therefore, Be/X-ray pulsars that are spinning down over periods spanning 18 yr are, in fact, accreting from retrograde discs. The presence of prograde and retrograde discs in roughly equal numbers supports a new evolutionary scenario for Be/X-ray pulsars in their spin period-period derivative diagram.

  15. Phase-space evolution of x-ray coherence in phase-sensitive imaging.

    PubMed

    Wu, Xizeng; Liu, Hong

    2008-08-01

    X-ray coherence evolution in the imaging process plays a key role for x-ray phase-sensitive imaging. In this work we present a phase-space formulation for the phase-sensitive imaging. The theory is reformulated in terms of the cross-spectral density and associated Wigner distribution. The phase-space formulation enables an explicit and quantitative account of partial coherence effects on phase-sensitive imaging. The presented formulas for x-ray spectral density at the detector can be used for performing accurate phase retrieval and optimizing the phase-contrast visibility. The concept of phase-space shearing length derived from this phase-space formulation clarifies the spatial coherence requirement for phase-sensitive imaging with incoherent sources. The theory has been applied to x-ray Talbot interferometric imaging as well. The peak coherence condition derived reveals new insights into three-grating-based Talbot-interferometric imaging and gratings-based x-ray dark-field imaging.

  16. Utilization of DXA Bone Mineral Densitometry in Ontario

    PubMed Central

    2006-01-01

    Executive Summary Issue Systematic reviews and analyses of administrative data were performed to determine the appropriate use of bone mineral density (BMD) assessments using dual energy x-ray absorptiometry (DXA), and the associated trends in wrist and hip fractures in Ontario. Background Dual Energy X-ray Absorptiometry Bone Mineral Density Assessment Dual energy x-ray absorptiometry bone densitometers measure bone density based on differential absorption of 2 x-ray beams by bone and soft tissues. It is the gold standard for detecting and diagnosing osteoporosis, a systemic disease characterized by low bone density and altered bone structure, resulting in low bone strength and increased risk of fractures. The test is fast (approximately 10 minutes) and accurate (exceeds 90% at the hip), with low radiation (1/3 to 1/5 of that from a chest x-ray). DXA densitometers are licensed as Class 3 medical devices in Canada. The World Health Organization has established criteria for osteoporosis and osteopenia based on DXA BMD measurements: osteoporosis is defined as a BMD that is >2.5 standard deviations below the mean BMD for normal young adults (i.e. T-score <–2.5), while osteopenia is defined as BMD that is more than 1 standard deviation but less than 2.5 standard deviation below the mean for normal young adults (i.e. T-score< –1 & ≥–2.5). DXA densitometry is presently an insured health service in Ontario. Clinical Need   Burden of Disease The Canadian Multicenter Osteoporosis Study (CaMos) found that 16% of Canadian women and 6.6% of Canadian men have osteoporosis based on the WHO criteria, with prevalence increasing with age. Osteopenia was found in 49.6% of Canadian women and 39% of Canadian men. In Ontario, it is estimated that nearly 530,000 Ontarians have some degrees of osteoporosis. Osteoporosis-related fragility fractures occur most often in the wrist, femur and pelvis. These fractures, particularly those in the hip, are associated with increased

  17. X-ray beamsplitter

    DOEpatents

    Ceglio, N.M.; Stearns, D.G.; Hawryluk, A.M.; Barbee, T.W. Jr.

    1987-08-07

    An x-ray beamsplitter which splits an x-ray beam into two coherent parts by reflecting and transmitting some fraction of an incident beam has applications for x-ray interferometry, x-ray holography, x-ray beam manipulation, and x-ray laser cavity output couplers. The beamsplitter is formed of a wavelength selective multilayer thin film supported by a very thin x-ray transparent membrane. The beamsplitter resonantly transmits and reflects x-rays through thin film interference effects. A thin film is formed of 5--50 pairs of alternate Mo/Si layers with a period of 20--250 A. The support membrane is 10--200 nm of silicon nitride or boron nitride. The multilayer/support membrane structure is formed across a window in a substrate by first forming the structure on a solid substrate and then forming a window in the substrate to leave a free-standing structure over the window. 6 figs.

  18. Luminosity of serendipitous x-ray QSOs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Margon, B.; Chanan, G.A.; Downes, R.A.

    1982-02-01

    We have identified the optical counterparts of 47 serendipitously discovered Einstein Observatory X-ray sources with previously unreported quasi-stellar objects. The mean ratio of X-ray to optical luminosity of this sample agrees reasonably well with that derived from X-ray observations of previously known QSOs. However, despite the fact that our limiting magnitude V = 18.5 should permit detection of typical QSOs (i.e., M/sub c/ = -26) to z = 0.9, the mean redshift of our sample is only z = 0.42 Thus the mean luminosity of these objects, M/sub c/ = -24, differs significantly from that of previous QSO surveys withmore » similar optical thresholds. The existence of large numbers of these lower luminosity QSOs which are difficult to discover by previous selection techniques, provides observational confirmation of the steep luminosity function inferred indirectly from optical counts. However, possible explanations for the lack of higher luminosity QSOs in our sample prove even more interesting. If one accepts the global value of the X-ray to optical luminosity ratio proposed by Zamorani et al, and Ku, Helfand, and Lucy, then reconciliation of this ratio with our observations severely constrains the QSO space density and luminosity functions. Alternatively, the ''typical'' QSO-a radio quiet, high redshift (z>1), optically luminous but not superluminous (M/sub c/> or =-27) object-may not be a strong X-ray source. This inference is not in conflict with existing results from Einstein X-ray surveys of preselected QSOs, which also fail to detect such objects. The contribution of QSOs to the diffuse X-ray background radiation is therefore highly uncertain, but may be quite small. Current X-ray data probably do not place significant constraints on the optical number counts of faint QSOs.« less

  19. Bone mineral measurement using dual energy x ray densitometry

    NASA Technical Reports Server (NTRS)

    Smith, Steven W.

    1989-01-01

    Bone mineral measurements before and after space missions have shown that weightlessness greatly accelerates bone demineralization. Bone mineral losses as high as 1 to 3 percent per month were reported. Highly precise instrumentation is required to monitor this loss and thereby test the efficacy of treatment. During the last year, a significant improvement was made in Dual-Photon Absorptiometry by replacing the radioactive source with an x ray tube. Advantages of this system include: better precision, lower patient dose, better spacial resolution, and shorter scan times. The high precision and low radiation dose of this technique will allow detection of bone mineral changes of less than 1 percent with measurements conducted directly at the sites of interest. This will allow the required bone mineral studies to be completed in a shorter time with greater confidence.

  20. Spherical grating based x-ray Talbot interferometry.

    PubMed

    Cong, Wenxiang; Xi, Yan; Wang, Ge

    2015-11-01

    Grating interferometry is a state-of-the-art x-ray imaging approach, which can acquire information on x-ray attenuation, phase shift, and small-angle scattering simultaneously. Phase-contrast imaging and dark-field imaging are very sensitive to microstructural variation and offers superior contrast resolution for biological soft tissues. However, a common x-ray tube is a point-like source. As a result, the popular planar grating imaging configuration seriously restricts the flux of photons and decreases the visibility of signals, yielding a limited field of view. The purpose of this study is to extend the planar x-ray grating imaging theory and methods to a spherical grating scheme for a wider range of preclinical and clinical applications. A spherical grating matches the wave front of a point x-ray source very well, allowing the perpendicular incidence of x-rays on the grating to achieve a higher visibility over a larger field of view than the planer grating counterpart. A theoretical analysis of the Talbot effect for spherical grating imaging is proposed to establish a basic foundation for x-ray spherical gratings interferometry. An efficient method of spherical grating imaging is also presented to extract attenuation, differential phase, and dark-field images in the x-ray spherical grating interferometer. Talbot self-imaging with spherical gratings is analyzed based on the Rayleigh-Sommerfeld diffraction formula, featuring a periodic angular distribution in a polar coordinate system. The Talbot distance is derived to reveal the Talbot self-imaging pattern. Numerical simulation results show the self-imaging phenomenon of a spherical grating interferometer, which is in agreement with the theoretical prediction. X-ray Talbot interferometry with spherical gratings has a significant practical promise. Relative to planar grating imaging, spherical grating based x-ray Talbot interferometry has a larger field of view and improves both signal visibility and dose

  1. Social determinants of bone densitometry uptake for osteoporosis risk in patients aged 50yr and older: a systematic review.

    PubMed

    Brennan, Sharon L; Wluka, Anita E; Gould, Haslinda; Nicholson, Geoffrey C; Leslie, William D; Ebeling, Peter R; Oldenburg, Brian; Kotowicz, Mark A; Pasco, Julie A

    2012-01-01

    The World Health Organization identifies that osteoporosis is one of the leading health problems in the Western world. An increased risk of fragility fracture is observed in more socially disadvantaged individuals in most Western countries. Dual-energy X-ray absorptiometry (DXA) is currently the procedure of choice to diagnose osteoporosis and assess fracture risk. We systematically reviewed the literature regarding social determinants of DXA utilization for osteoporosis detection in patients aged 50yr and older using a computer-aided search of MEDLINE, EMBASE, CINAHL, and PsychINFO from January 1994 to December 2010. Five cross-sectional studies, incorporating 16 separate analyses, were identified for inclusion in this review. The best evidence analysis identified limited evidence for a positive association between either income or education with DXA utilization; furthermore, the best evidence analysis found no evidence for an association between either marital status or working status and DXA utilization. Further research is required to identify whether a relationship exists and elucidate reasons for disparities in DXA utilization between different social groups, such as choice and referral processes, as a necessary precursor in identifying modifiable determinants and appropriate strategies to promote preventive screening to identify fracture risk. Copyright © 2012 The International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.

  2. Fracture Prediction by Computed Tomography and Finite Element Analysis: Current and Future Perspectives.

    PubMed

    Johannesdottir, Fjola; Allaire, Brett; Bouxsein, Mary L

    2018-05-30

    This review critiques the ability of CT-based methods to predict incident hip and vertebral fractures. CT-based techniques with concurrent calibration all show strong associations with incident hip and vertebral fracture, predicting hip and vertebral fractures as well as, and sometimes better than, dual-energy X-ray absorptiometry areal biomass density (DXA aBMD). There is growing evidence for use of routine CT scans for bone health assessment. CT-based techniques provide a robust approach for osteoporosis diagnosis and fracture prediction. It remains to be seen if further technical advances will improve fracture prediction compared to DXA aBMD. Future work should include more standardization in CT analyses, establishment of treatment intervention thresholds, and more studies to determine whether routine CT scans can be efficiently used to expand the number of individuals who undergo evaluation for fracture risk.

  3. Bone density in patients with chondromalacia patella.

    PubMed

    Salehi, Iraj; Khazaeli, Shabnam; Hatami, Parta; Malekpour, Mahdi

    2010-06-01

    Chondromalacia of the patella is the most common cause of anterior knee pain in young women. The etiology of the disease is not well-understood but the initial lesion is a disorganization of collagenous structures. Since the disease is proposed to be due to generalized constitutional disturbance, we postulated that bony structures could also be involved. To investigate this hypothesis we measured the bone density of 286 patients with the diagnosis of chondromalacia of the patella during a 4-year period using dual energy X-ray absorptiometry (DXA) method. We found a significant number of patients having low bone densities. This problem was more pronounced in men and in younger age groups. We suggest base-line bone density evaluation in all patients, treatment of osteopenia or osteoporosis in select patients and regular follow-ups using DXA.

  4. X-Ray Polarization from High Mass X-Ray Binaries

    NASA Technical Reports Server (NTRS)

    Kallman, T.; Dorodnitsyn, A.; Blondin, J.

    2015-01-01

    X-ray astronomy allows study of objects which may be associated with compact objects, i.e. neutron stars or black holes, and also may contain strong magnetic fields. Such objects are categorically non-spherical, and likely non-circular when projected on the sky. Polarization allows study of such geometric effects, and X-ray polarimetry is likely to become feasible for a significant number of sources in the future. A class of potential targets for future X-ray polarization observations is the high mass X-ray binaries (HMXBs), which consist of a compact object in orbit with an early type star. In this paper we show that X-ray polarization from HMXBs has a distinct signature which depends on the source inclination and orbital phase. The presence of the X-ray source displaced from the star creates linear polarization even if the primary wind is spherically symmetric whenever the system is viewed away from conjunction. Direct X-rays dilute this polarization whenever the X-ray source is not eclipsed; at mid-eclipse the net polarization is expected to be small or zero if the wind is circularly symmetric around the line of centers. Resonance line scattering increases the scattering fraction, often by large factors, over the energy band spanned by resonance lines. Real winds are not expected to be spherically symmetric, or circularly symmetric around the line of centers, owing to the combined effects of the compact object gravity and ionization on the wind hydrodynamics. A sample calculation shows that this creates polarization fractions ranging up to tens of percent at mid-eclipse.

  5. Be/X-ray Binary Science for Future X-ray Timing Missions

    NASA Technical Reports Server (NTRS)

    Wilson-Hodge, Colleen A.

    2011-01-01

    For future missions, the Be/X-ray binary community needs to clearly define our science priorities for the future to advocate for their inclusion in future missions. In this talk, I will describe current designs for two potential future missions and Be X-ray binary science enabled by these designs. The Large Observatory For X-ray Timing (LOFT) is an X-ray timing mission selected in February 2011 for the assessment phase from the 2010 ESA M3 call for proposals. The Advanced X-ray Timing ARray (AXTAR) is a NASA explorer concept X-ray timing mission. This talk is intended to initiate discussions of our science priorities for the future.

  6. DUAL-ENERGY X-RAY ABSORPTIOMETRY AND CALCULATED FRAX RISK SCORES MAY UNDERESTIMATE OSTEOPOROTIC FRACTURE RISK IN VITAMIN D-DEFICIENT VETERANS WITH HIV INFECTION.

    PubMed

    Stephens, Kelly I; Rubinsztain, Leon; Payan, John; Rentsch, Chris; Rimland, David; Tangpricha, Vin

    2016-04-01

    We evaluated the utility of the World Health Organization (WHO) Fracture Risk Assessment Tool (FRAX) in assessing fracture risk in patients with human immunodeficiency virus (HIV) and vitamin D deficiency. This was a retrospective study of HIV-infected patients with co-existing vitamin D deficiency at the Atlanta Veterans Affairs Medical Center. Bone mineral density (BMD) was assessed by dual-energy X-ray absorptiometry (DEXA), and the 10-year fracture risk was calculated by the WHO FRAX algorithm. Two independent radiologists reviewed lateral chest radiographs for the presence of subclinical vertebral fractures. We identified 232 patients with HIV and vitamin D deficiency. Overall, 15.5% of patients met diagnostic criteria for osteoporosis on DEXA, and 58% had low BMD (T-score between -1 and -2.5). The median risk of any major osteoporotic and hip fracture by FRAX score was 1.45 and 0.10%, respectively. Subclinical vertebral fractures were detected in 46.6% of patients. Compared to those without fractures, those with fractures had similar prevalence of osteoporosis (15.3% versus 15.7%; P>.999), low BMD (53.2% versus 59.3%; P = .419), and similar FRAX hip scores (0.10% versus 0.10%; P = .412). While the FRAX major score was lower in the nonfracture group versus fracture group (1.30% versus 1.60%; P = .025), this was not clinically significant. We found a high prevalence of subclinical vertebral fractures among vitamin D-deficient HIV patients; however, DEXA and FRAX failed to predict those with fractures. Our results suggest that traditional screening tools for fragility fractures may not be applicable to this high-risk patient population.

  7. Abdomen X-Ray (Radiography)

    MedlinePlus

    ... News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Abdomen Abdominal x-ray uses a ... of an abdominal x-ray? What is abdominal x-ray? An x-ray (radiograph) is a noninvasive ...

  8. A search for X-ray polarization in cosmic X-ray sources. [binary X-ray sources and supernovae remnants

    NASA Technical Reports Server (NTRS)

    Hughes, J. P.; Long, K. S.; Novick, R.

    1983-01-01

    Fifteen strong X-ray sources were observed by the X-ray polarimeters on board the OSO-8 satellite from 1975 to 1978. The final results of this search for X-ray polarization in cosmic sources are presented in the form of upper limits for the ten sources which are discussed elsewhere. These limits in all cases are consistent with a thermal origin for the X-ray emission.

  9. X-Ray Emission from the Soft X-Ray Transient Aquila X-1

    NASA Technical Reports Server (NTRS)

    Tavani, Marco

    1998-01-01

    Aquila X-1 is the most prolific of soft X-ray transients. It is believed to contain a rapidly spinning neutron star sporadically accreting near the Eddington limit from a low-mass companion star. The interest in studying the repeated X-ray outbursts from Aquila X-1 is twofold: (1) studying the relation between optical, soft and hard X-ray emission during the outburst onset, development and decay; (2) relating the spectral component to thermal and non-thermal processes occurring near the magnetosphere and in the boundary layer of a time-variable accretion disk. Our investigation is based on the BATSE monitoring of Aquila X-1 performed by our group. We observed Aquila X-1 in 1997 and re-analyzed archival information obtained in April 1994 during a period of extraordinary outbursting activity of the source in the hard X-ray range. Our results allow, for the first time for this important source, to obtain simultaneous spectral information from 2 keV to 200 keV. A black body (T = 0.8 keV) plus a broken power-law spectrum describe accurately the 1994 spectrum. Substantial hard X-ray emission is evident in the data, confirming that the accretion phase during sub-Eddington limit episodes is capable of producing energetic hard emission near 5 x 10(exp 35) ergs(exp -1). A preliminary paper summarizes our results, and a more comprehensive account is being written. We performed a theoretical analysis of possible emission mechanisms, and confirmed that a non-thermal emission mechanism triggered in a highly sheared magnetosphere at the accretion disk inner boundary can explain the hard X-ray emission. An anticorrelation between soft and hard X-ray emission is indeed prominently observed as predicted by this model.

  10. Monte Carlo derivation of filtered tungsten anode X-ray spectra for dose computation in digital mammography*

    PubMed Central

    Paixão, Lucas; Oliveira, Bruno Beraldo; Viloria, Carolina; de Oliveira, Marcio Alves; Teixeira, Maria Helena Araújo; Nogueira, Maria do Socorro

    2015-01-01

    Objective Derive filtered tungsten X-ray spectra used in digital mammography systems by means of Monte Carlo simulations. Materials and Methods Filtered spectra for rhodium filter were obtained for tube potentials between 26 and 32 kV. The half-value layer (HVL) of simulated filtered spectra were compared with those obtained experimentally with a solid state detector Unfors model 8202031-H Xi R/F & MAM Detector Platinum and 8201023-C Xi Base unit Platinum Plus w mAs in a Hologic Selenia Dimensions system using a direct radiography mode. Results Calculated HVL values showed good agreement as compared with those obtained experimentally. The greatest relative difference between the Monte Carlo calculated HVL values and experimental HVL values was 4%. Conclusion The results show that the filtered tungsten anode X-ray spectra and the EGSnrc Monte Carlo code can be used for mean glandular dose determination in mammography. PMID:26811553

  11. Unilateral vs bilateral hip bone mineral density measurement for the diagnosis of osteoporosis.

    PubMed

    Ikegami, Shota; Kamimura, Mikio; Uchiyama, Shigeharu; Mukaiyama, Keijiro; Kato, Hiroyuki

    2014-01-01

    It has not been established whether unilateral or bilateral hip dual-energy X-ray absorptiometry (DXA) is preferable for the diagnosis of osteoporosis. We investigated the discordance in DXA measurements in bilateral hips to determine whether unilateral DXA is valid for osteoporosis diagnosis. The subjects were 2964 Japanese patients without a previous diagnosis of primary osteoporosis. We measured bilateral femoral bone mineral density (BMD) and calculated indices, related to the unilateral results, for predicting contralateral hip osteoporosis. A likelihood ratio (LR) of a negative test (LR [-]) of less than 0.2 was considered to exclude the diagnosis. In the normal spinal BMD group, the sensitivity of unilateral DXA for women was 27-73% and LR (-) was 0.28-0.73; the sensitivity for men was 0-50% and LR (-) was 0.51-1.00; the diagnosis of contralateral osteoporosis was not excluded. Sensitivity increased and LR (-) increased with worsening spinal BMD status; however, LR (-) did not meet the cutoff for exclusion. We could exclude unilateral hip osteoporosis, in women only, by performing contralateral femoral DXA; this necessitated lowering the T-score cutoff from -2.5 to -2.0. Unilateral femoral DXA is not useful for excluding the diagnosis of contralateral hip osteoporosis. Copyright © 2014 The International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.

  12. "X-Ray Transients in Star-Forming Regions" and "Hard X-Ray Emission from X-Ray Bursters"

    NASA Technical Reports Server (NTRS)

    Halpern, Jules P.; Kaaret, Philip

    1999-01-01

    This grant funded work on the analysis of data obtained with the Burst and Transient Experiment (BATSE) on the Compton Gamma-Ray Observatory. The goal of the work was to search for hard x-ray transients in star forming regions using the all-sky hard x-ray monitoring capability of BATSE. Our initial work lead to the discovery of a hard x-ray transient, GRO J1849-03. Follow-up observations of this source made with the Wide Field Camera on BeppoSAX showed that the source should be identified with the previously known x-ray pulsar GS 1843-02 which itself is identified with the x-ray source X1845-024 originally discovered with the SAS-3 satellite. Our identification of the source and measurement of the outburst recurrence time, lead to the identification of the source as a Be/X-ray binary with a spin period of 94.8 s and an orbital period of 241 days. The funding was used primarily for partial salary and travel support for John Tomsick, then a graduate student at Columbia University. John Tomsick, now Dr. Tomsick, received his Ph.D. from Columbia University in July 1999, based partially on results obtained under this investigation. He is now a postdoctoral research scientist at the University of California, San Diego.

  13. Lumbosacral spine x-ray

    MedlinePlus

    X-ray - lumbosacral spine; X-ray - lower spine ... The test is done in a hospital x-ray department or your health care provider's office by an x-ray technician. You will be asked to lie on the x-ray ...

  14. X-ray ptychography

    NASA Astrophysics Data System (ADS)

    Pfeiffer, Franz

    2018-01-01

    X-ray ptychographic microscopy combines the advantages of raster scanning X-ray microscopy with the more recently developed techniques of coherent diffraction imaging. It is limited neither by the fabricational challenges associated with X-ray optics nor by the requirements of isolated specimen preparation, and offers in principle wavelength-limited resolution, as well as stable access and solution to the phase problem. In this Review, we discuss the basic principles of X-ray ptychography and summarize the main milestones in the evolution of X-ray ptychographic microscopy and tomography over the past ten years, since its first demonstration with X-rays. We also highlight the potential for applications in the life and materials sciences, and discuss the latest advanced concepts and probable future developments.

  15. Disentangling AGN and Star Formation in Soft X-Rays

    NASA Technical Reports Server (NTRS)

    LaMassa, Stephanie M.; Heckman, T. M.; Ptak, A.

    2012-01-01

    We have explored the interplay of star formation and active galactic nucleus (AGN) activity in soft X-rays (0.5-2 keV) in two samples of Seyfert 2 galaxies (Sy2s). Using a combination of low-resolution CCD spectra from Chandra and XMM-Newton, we modeled the soft emission of 34 Sy2s using power-law and thermal models. For the 11 sources with high signal-to-noise Chandra imaging of the diffuse host galaxy emission, we estimate the luminosity due to star formation by removing the AGN, fitting the residual emission. The AGN and star formation contributions to the soft X-ray luminosity (i.e., L(sub x,AGN) and L(sub x,SF)) for the remaining 24 Sy2s were estimated from the power-law and thermal luminosities derived from spectral fitting. These luminosities were scaled based on a template derived from XSINGS analysis of normal star-forming galaxies. To account for errors in the luminosities derived from spectral fitting and the spread in the scaling factor, we estimated L(sub x,AGN) and L(sub x,SF))from Monte Carlo simulations. These simulated luminosities agree with L(sub x,AGN) and L(sub x,SF) derived from Chandra imaging analysis within a 3sigma confidence level. Using the infrared [Ne ii]12.8 micron and [O iv]26 micron lines as a proxy of star formation and AGN activity, respectively, we independently disentangle the contributions of these two processes to the total soft X-ray emission. This decomposition generally agrees with L(sub x,SF) and L(sub x,AGN) at the 3 sigma level. In the absence of resolvable nuclear emission, our decomposition method provides a reasonable estimate of emission due to star formation in galaxies hosting type 2 AGNs.

  16. Optical spectroscopy of the Be/X-ray binary V850 Centauri/GX 304-1 during faint X-ray periodical activity

    NASA Astrophysics Data System (ADS)

    Malacaria, C.; Kollatschny, W.; Whelan, E.; Santangelo, A.; Klochkov, D.; McBride, V.; Ducci, L.

    2017-07-01

    Context. Be/X-ray binaries (BeXRBs) are the most populous class of high-mass X-ray binaries. Their X-ray duty cycle is tightly related to the optical companion wind activity, which in turn can be studied through dedicated optical spectroscopic observations. Aims: We study optical spectral features of the Be circumstellar disk to test their long-term variability and their relation with the X-ray activity. Special attention has been given to the Hα emission line, one of the best tracers of the disk conditions. Methods: We obtained optical broadband medium resolution spectra from a dedicated campaign with the Anglo-Australian Telescope and the Southern African Large Telescope in 2014-2015. Data span over one entire binary orbit, and cover both X-ray quiescent and moderately active periods. We used Balmer emission lines to follow the evolution of the circumstellar disk. Results: We observe prominent spectral features, like double-peaked Hα and Hβ emission lines. The HαV/R ratio significantly changes over a timescale of about one year. Our observations are consistent with a system observed at a large inclination angle (I ≳ 60°). The derived circumstellar disk size shows that the disk evolves from a configuration that prevents accretion onto the neutron star, to one that allows only moderate accretion. This is in agreement with the contemporary observed X-ray activity. Our results are interpreted within the context of inefficient tidal truncation of the circumstellar disk, as expected for this source's binary configuration. We derived the Hβ-emitting region size, which is equal to about half of the corresponding Hα-emitting disk, and constrain the luminosity class of V850 Cen as III-V, consistent with the previously proposed class.

  17. UNDERSTANDING X-RAY STARS:. The Discovery of Binary X-ray Sources

    NASA Astrophysics Data System (ADS)

    Schreier, E. J.; Tananbaum, H.

    2000-09-01

    The discovery of binary X-ray sources with UHURU introduced many new concepts to astronomy. It provided the canonical model which explained X-ray emission from a large class of galactic X-ray sources: it confirmed the existence of collapsed objects as the source of intense X-ray emission; showed that such collapsed objects existed in binary systems, with mass accretion as the energy source for the X-ray emission; and provided compelling evidence for the existence of black holes. This model also provided the basis for explaining the power source of AGNs and QSOs. The process of discovery and interpretation also established X-ray astronomy as an essential sub-discipline of astronomy, beginning its incorporation into the mainstream of astronomy.

  18. Thoracic spine x-ray

    MedlinePlus

    Vertebral radiography; X-ray - spine; Thoracic x-ray; Spine x-ray; Thoracic spine films; Back films ... The test is done in a hospital radiology department or in the health care provider's office. You will lie on the x-ray table in different positions. If the x-ray ...

  19. X-ray binaries

    NASA Technical Reports Server (NTRS)

    1976-01-01

    Satellite X-ray experiments and ground-based programs aimed at observation of X-ray binaries are discussed. Experiments aboard OAO-3, OSO-8, Ariel 5, Uhuru, and Skylab are included along with rocket and ground-based observations. Major topics covered are: Her X-1, Cyg X-3, Cen X-3, Cyg X-1, the transient source A0620-00, other possible X-ray binaries, and plans and prospects for future observational programs.

  20. Bone mineral density in patients with alopecia areata treated with long-term intralesional corticosteroids.

    PubMed

    Samrao, Aman; Fu, Jennifer M; Harris, Steven T; Price, Vera H

    2013-02-01

    Intralesional corticosteroid injections are a common treatment for patchy alopecia areata, the most prevalent subtype of this autoimmune hair disorder. To date, no studies have examined the potential adverse effects of this therapy on bone mineral density (BMD). In this retrospective, cross-sectional case series, 18 patients with patchy alopecia areata treated at 4- to 8-week intervals with intralesional triamcinolone acetonide for at least 20 months were evaluated for BMD using dual-energy x-ray absorptiometry (DXA). Follow-up DXA measurements were obtained in those with abnormal findings. Nine out of 18 patients (50%) had abnormal DXA results. Patients with the following risk factors were more likely to have abnormal BMD: age older than 50 years, body mass index less than 18.5 kg/m2, lack of weight-bearing exercise, smoking history, postmenopausal status, past stress fracture, family history of osteopenia or osteoporosis, and a cumulative intralesional triamcinolone acetonide dose of greater than 500 mg. Patients with patchy alopecia areata who receive chronic intralesional triamcinolone acetonide therapy should be counseled on preventive measures for osteoporosis and monitored for effects on BMD.

  1. Studies of auroral X-ray imaging from high altitude spacecraft

    NASA Technical Reports Server (NTRS)

    Mckenzie, D. L.; Mizera, P. F.; Rice, C. J.

    1980-01-01

    Results of a study of techniques for imaging the aurora from a high altitude satellite at X-ray wavelengths are summarized. The X-ray observations allow the straightforward derivation of the primary auroral X-ray spectrum and can be made at all local times, day and night. Five candidate imaging systems are identified: X-ray telescope, multiple pinhole camera, coded aperture, rastered collimator, and imaging collimator. Examples of each are specified, subject to common weight and size limits which allow them to be intercompared. The imaging ability of each system is tested using a wide variety of sample spectra which are based on previous satellite observations. The study shows that the pinhole camera and coded aperture are both good auroral imaging systems. The two collimated detectors are significantly less sensitive. The X-ray telescope provides better image quality than the other systems in almost all cases, but a limitation to energies below about 4 keV prevents this system from providing the spectra data essential to deriving electron spectra, energy input to the atmosphere, and atmospheric densities and conductivities. The orbit selection requires a tradeoff between spatial resolution and duty cycle.

  2. Skull x-ray

    MedlinePlus

    X-ray - head; X-ray - skull; Skull radiography; Head x-ray ... Chernecky CC, Berger BJ. Radiography of skull, chest, and cervical spine - diagnostic. In: Chernecky CC, Berger BJ, eds. Laboratory Tests and Diagnostic Procedures . 6th ed. ...

  3. X-Ray Scaling Relations of Early-type Galaxies

    NASA Astrophysics Data System (ADS)

    Babyk, Iu. V.; McNamara, B. R.; Nulsen, P. E. J.; Hogan, M. T.; Vantyghem, A. N.; Russell, H. R.; Pulido, F. A.; Edge, A. C.

    2018-04-01

    X-ray luminosity, temperature, gas mass, total mass, and their scaling relations are derived for 94 early-type galaxies (ETGs) using archival Chandra X-ray Observatory observations. Consistent with earlier studies, the scaling relations, L X ∝ T 4.5±0.2, M ∝ T 2.4±0.2, and L X ∝ M 2.8±0.3, are significantly steeper than expected from self-similarity. This steepening indicates that their atmospheres are heated above the level expected from gravitational infall alone. Energetic feedback from nuclear black holes and supernova explosions are likely heating agents. The tight L X –T correlation for low-luminosity systems (i.e., below 1040 erg s‑1) are at variance with hydrodynamical simulations, which generally predict higher temperatures for low-luminosity galaxies. We also investigate the relationship between total mass and pressure, Y X = M g × T, finding M\\propto {Y}X0.45+/- 0.04. We explore the gas mass to total mass fraction in ETGs and find a range of 0.1%–1.0%. We find no correlation between the gas-to-total mass fraction with temperature or total mass. Higher stellar velocity dispersions and higher metallicities are found in hotter, brighter, and more massive atmospheres. X-ray core radii derived from β-model fitting are used to characterize the degree of core and cuspiness of hot atmospheres.

  4. Full-field transmission x-ray imaging with confocal polycapillary x-ray optics

    PubMed Central

    Sun, Tianxi; MacDonald, C. A.

    2013-01-01

    A transmission x-ray imaging setup based on a confocal combination of a polycapillary focusing x-ray optic followed by a polycapillary collimating x-ray optic was designed and demonstrated to have good resolution, better than the unmagnified pixel size and unlimited by the x-ray tube spot size. This imaging setup has potential application in x-ray imaging for small samples, for example, for histology specimens. PMID:23460760

  5. Predicting visceral adipose tissue by MRI using DXA and anthropometry in adolescents and young adults

    PubMed Central

    Laddu, Deepika R.; Lee, Vinson R.; Blew, Robert M.; Sato, Tetsuya; Lohman, Timothy G.; Going, Scott B.

    2015-01-01

    Objective Accumulation of intra-abdominal (visceral) adipose tissue, independent of total adiposity, is associated with development of metabolic abnormalities such as insulin resistance and type-2 diabetes in children and adults. The objective of this study was to develop prediction equations for estimating visceral adiposity (VAT) measured by magnetic resonance imaging (MRI) using anthropometric variables and measures of abdominal fat mass from DXA in adolescents and young adults. Methods Cross-sectional data was collected from a multiethnic population of seventy males and females, aged 12–25 years, with BMI ranging from 14.5–38.1 kg/m2. Android (AFM; android region as defined by manufacturers instruction) and lumbar L1-L4 regional fat masses were assessed using DXA (GE Lunar Prodigy; GE Lunar Corp, Madison, WI, USA). Criterion measures of intra-abdominal visceral fat were obtained using single-slice MRI (General Electric Signa Model 5x 1.5T) and VAT area was analyzed at the level OF L4–L5. Image analysis was carried out using ZedView 3.1. Results DXA measures of AFM (r=0.76) and L1-L4 (r=0.71) were significantly (P<0.0001) correlated with MRI-measured VAT. DXA AFM, together with gender and weight, explained 62% of the variance in VAT (SEE=10.06 cm2). DXA L1-L4 fat mass with gender explained 54% of the variance in VAT (SEE=11.08 cm2). Addition of the significant interaction, gender × DXA fat mass, improved prediction of VAT from AFM (Radj2=0.61, SEE=10.10cm2) and L1-L4 (Radj2=0.59, SEE=10.39cm2). Conclusion These results demonstrate that VAT is accurately estimated from regional fat masses measured by DXA in adolescents and young adults. PMID:26097436

  6. X-ray generator

    DOEpatents

    Dawson, John M.

    1976-01-01

    Apparatus and method for producing coherent secondary x-rays that are controlled as to direction by illuminating a mixture of high z and low z gases with an intense burst of primary x-rays. The primary x-rays are produced with a laser activated plasma, and these x-rays strip off the electrons of the high z atoms in the lasing medium, while the low z atoms retain their electrons. The neutral atoms transfer electrons to highly excited states of the highly striped high z ions giving an inverted population which produces the desired coherent x-rays. In one embodiment, a laser, light beam provides a laser spark that produces the intense burst of coherent x-rays that illuminates the mixture of high z and low z gases, whereby the high z atoms are stripped while the low z ones are not, giving the desired mixture of highly ionized and neutral atoms. To this end, the laser spark is produced by injecting a laser light beam, or a plurality of beams, into a first gas in a cylindrical container having an adjacent second gas layer co-axial therewith, the laser producing a plasma and the intense primary x-rays in the first gas, and the second gas containing the high and low atomic number elements for receiving the primary x-rays, whereupon the secondary x-rays are produced therein by stripping desired ions in a neutral gas and transfer of electrons to highly excited states of the stripped ions from the unionized atoms. Means for magnetically confining and stabilizing the plasma are disclosed for controlling the direction of the x-rays.

  7. Comparison of methods for the measurement of body composition in overweight and obese Brazilian children and adolescents before and after a lifestyle modification program.

    PubMed

    Lyra, Arthur; Bonfitto, Alexandre José; Barbosa, Vera Lucia P; Bezerra, Ana Cristina; Longui, Carlos Alberto; Monte, Osmar; Kochi, Cristiane

    2015-01-01

    To compare the body composition of overweight children and adolescents by bioelectrical impedance analysis (BIA) and dual-energy X-ray absorptiometry (DXA) before and after physical activity program. One hundred and eleven patients with mean age (SD) of 12 (1.9) participated in the study. We assessed the weight, height, waist circumference (WC), and body composition by DXA and BIA. Patients underwent a program of diet and physical activity (1 h 30 min/day, 3 times a week for 3 months) and were evaluated before and after this period. Mean initial zBMI were 2.3 (0.5) and waist SDS 5.9 (1.8). Significant differences were observed when we compared the measurements taken by DXA and BIA, respectively: total body fat percentage (40 and 31.5) and fat-free mass (43.1 and 50.6 kg). Regarding the trunk fat by DXA, there was a positive correlation with the WC/height ratio (r = 0.65; p < 0.01). After the intervention period, we observed a reduction in the zBMI, waist SDS, and total body fat and increase of fat-free mass by DXA. BIA only detected reduction in fat. BIA underestimates the percentage of fat and overestimates fat-free mass in relation to DXA. There is positive correlation between trunk fat and the ratio WC/height. In addition, DXA detected changes in body composition induced by a short period of physical training, unlike BIA. © 2014 S. Karger AG, Basel.

  8. Spherical grating based x-ray Talbot interferometry

    PubMed Central

    Cong, Wenxiang; Xi, Yan; Wang, Ge

    2015-01-01

    Purpose: Grating interferometry is a state-of-the-art x-ray imaging approach, which can acquire information on x-ray attenuation, phase shift, and small-angle scattering simultaneously. Phase-contrast imaging and dark-field imaging are very sensitive to microstructural variation and offers superior contrast resolution for biological soft tissues. However, a common x-ray tube is a point-like source. As a result, the popular planar grating imaging configuration seriously restricts the flux of photons and decreases the visibility of signals, yielding a limited field of view. The purpose of this study is to extend the planar x-ray grating imaging theory and methods to a spherical grating scheme for a wider range of preclinical and clinical applications. Methods: A spherical grating matches the wave front of a point x-ray source very well, allowing the perpendicular incidence of x-rays on the grating to achieve a higher visibility over a larger field of view than the planer grating counterpart. A theoretical analysis of the Talbot effect for spherical grating imaging is proposed to establish a basic foundation for x-ray spherical gratings interferometry. An efficient method of spherical grating imaging is also presented to extract attenuation, differential phase, and dark-field images in the x-ray spherical grating interferometer. Results: Talbot self-imaging with spherical gratings is analyzed based on the Rayleigh–Sommerfeld diffraction formula, featuring a periodic angular distribution in a polar coordinate system. The Talbot distance is derived to reveal the Talbot self-imaging pattern. Numerical simulation results show the self-imaging phenomenon of a spherical grating interferometer, which is in agreement with the theoretical prediction. Conclusions: X-ray Talbot interferometry with spherical gratings has a significant practical promise. Relative to planar grating imaging, spherical grating based x-ray Talbot interferometry has a larger field of view and

  9. Spherical grating based x-ray Talbot interferometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cong, Wenxiang, E-mail: congw@rpi.edu, E-mail: xiy2@rpi.edu, E-mail: wangg6@rpi.edu; Xi, Yan, E-mail: congw@rpi.edu, E-mail: xiy2@rpi.edu, E-mail: wangg6@rpi.edu; Wang, Ge, E-mail: congw@rpi.edu, E-mail: xiy2@rpi.edu, E-mail: wangg6@rpi.edu

    2015-11-15

    Purpose: Grating interferometry is a state-of-the-art x-ray imaging approach, which can acquire information on x-ray attenuation, phase shift, and small-angle scattering simultaneously. Phase-contrast imaging and dark-field imaging are very sensitive to microstructural variation and offers superior contrast resolution for biological soft tissues. However, a common x-ray tube is a point-like source. As a result, the popular planar grating imaging configuration seriously restricts the flux of photons and decreases the visibility of signals, yielding a limited field of view. The purpose of this study is to extend the planar x-ray grating imaging theory and methods to a spherical grating scheme formore » a wider range of preclinical and clinical applications. Methods: A spherical grating matches the wave front of a point x-ray source very well, allowing the perpendicular incidence of x-rays on the grating to achieve a higher visibility over a larger field of view than the planer grating counterpart. A theoretical analysis of the Talbot effect for spherical grating imaging is proposed to establish a basic foundation for x-ray spherical gratings interferometry. An efficient method of spherical grating imaging is also presented to extract attenuation, differential phase, and dark-field images in the x-ray spherical grating interferometer. Results: Talbot self-imaging with spherical gratings is analyzed based on the Rayleigh–Sommerfeld diffraction formula, featuring a periodic angular distribution in a polar coordinate system. The Talbot distance is derived to reveal the Talbot self-imaging pattern. Numerical simulation results show the self-imaging phenomenon of a spherical grating interferometer, which is in agreement with the theoretical prediction. Conclusions: X-ray Talbot interferometry with spherical gratings has a significant practical promise. Relative to planar grating imaging, spherical grating based x-ray Talbot interferometry has a larger field of view and

  10. Women with previous fragility fractures can be classified based on bone microarchitecture and finite element analysis measured with HR-pQCT.

    PubMed

    Nishiyama, K K; Macdonald, H M; Hanley, D A; Boyd, S K

    2013-05-01

    High-resolution peripheral quantitative computed tomography (HR-pQCT) measurements of distal radius and tibia bone microarchitecture and finite element (FE) estimates of bone strength performed well at classifying postmenopausal women with and without previous fracture. The HR-pQCT measurements outperformed dual energy x-ray absorptiometry (DXA) at classifying forearm fractures and fractures at other skeletal sites. Areal bone mineral density (aBMD) is the primary measurement used to assess osteoporosis and fracture risk; however, it does not take into account bone microarchitecture, which also contributes to bone strength. Thus, our objective was to determine if bone microarchitecture measured with HR-pQCT and FE estimates of bone strength could classify women with and without low-trauma fractures. We used HR-pQCT to assess bone microarchitecture at the distal radius and tibia in 44 postmenopausal women with a history of low-trauma fracture and 88 age-matched controls from the Calgary cohort of the Canadian Multicentre Osteoporosis Study (CaMos) study. We estimated bone strength using FE analysis and simulated distal radius aBMD from the HR-pQCT scans. Femoral neck (FN) and lumbar spine (LS) aBMD were measured with DXA. We used support vector machines (SVM) and a tenfold cross-validation to classify the fracture cases and controls and to determine accuracy. The combination of HR-pQCT measures of microarchitecture and FE estimates of bone strength had the highest area under the receiver operating characteristic (ROC) curve of 0.82 when classifying forearm fractures compared to an area under the curve (AUC) of 0.71 from DXA-derived aBMD of the forearm and 0.63 from FN and spine DXA. For all fracture types, FE estimates of bone strength at the forearm alone resulted in an AUC of 0.69. Models based on HR-pQCT measurements of bone microarchitecture and estimates of bone strength performed better than DXA-derived aBMD at classifying women with and without prior fracture

  11. Technology Requirements for a Square Meter, Arcsecond Resolution Telescope for X-Rays: The SMART-X Mission

    NASA Technical Reports Server (NTRS)

    Schwartz, Daniel A.; Allured, Ryan; Bookbinder, Jay A.; Cotroneo, Vincenzo; Forman, William R.; Freeman, Mark D.; McMuldroch, Stuart; Reid, Paul B.; Tananbaum, Harvey; Vikhlinin, Alexey A.; hide

    2014-01-01

    Addressing the astrophysical problems of the 2020's requires sub-arcsecond x-ray imaging with square meter effective area. Such requirements can be derived, for example, by considering deep x-ray surveys to find the young black holes in the early universe (large redshifts) which will grow into the first super-massive black holes. We have envisioned a mission, the Square Meter Arcsecond Resolution Telescope for X-rays (SMART-X), based on adjustable x-ray optics technology, incorporating mirrors with the required small ratio of mass to collecting area. We are pursuing technology which achieves sub-arcsecond resolution by on-orbit adjustment via thin film piezoelectric "cells" deposited directly on the non-reflecting sides of thin, slumped glass. While SMART-X will also incorporate state-of-the-art x-ray cameras, the remaining spacecraft systems have no requirements more stringent than those which are well understood and proven on the current Chandra X-ray Observatory.

  12. X-ray lithography masking

    NASA Technical Reports Server (NTRS)

    Smith, Henry I. (Inventor); Lim, Michael (Inventor); Carter, James (Inventor); Schattenburg, Mark (Inventor)

    1998-01-01

    X-ray masking apparatus includes a frame having a supporting rim surrounding an x-ray transparent region, a thin membrane of hard inorganic x-ray transparent material attached at its periphery to the supporting rim covering the x-ray transparent region and a layer of x-ray opaque material on the thin membrane inside the x-ray transparent region arranged in a pattern to selectively transmit x-ray energy entering the x-ray transparent region through the membrane to a predetermined image plane separated from the layer by the thin membrane. A method of making the masking apparatus includes depositing back and front layers of hard inorganic x-ray transparent material on front and back surfaces of a substrate, depositing back and front layers of reinforcing material on the back and front layers, respectively, of the hard inorganic x-ray transparent material, removing the material including at least a portion of the substrate and the back layers of an inside region adjacent to the front layer of hard inorganic x-ray transparent material, removing a portion of the front layer of reinforcing material opposite the inside region to expose the surface of the front layer of hard inorganic x-ray transparent material separated from the inside region by the latter front layer, and depositing a layer of x-ray opaque material on the surface of the latter front layer adjacent to the inside region.

  13. Sinus x-ray

    MedlinePlus

    Paranasal sinus radiography; X-ray - sinuses ... sinus x-ray is taken in a hospital radiology department. Or the x-ray may be taken ... Brown J, Rout J. ENT, neck, and dental radiology. In: Adam A, Dixon AK, Gillard JH, Schaefer- ...

  14. X-Ray Data Booklet

    Science.gov Websites

    X-RAY DATA BOOKLET Center for X-ray Optics and Advanced Light Source Lawrence Berkeley National Laboratory Introduction X-Ray Properties of Elements Electron Binding Energies X-Ray Energy Emission Energies Table of X-Ray Properties Synchrotron Radiation Characteristics of Synchrotron Radiation History of X

  15. Chandra-SDSS Normal and Star-Forming Galaxies. I. X-Ray Source Properties of Galaxies Detected by the Chandra X-Ray Observatory in SDSS DR2

    NASA Astrophysics Data System (ADS)

    Hornschemeier, A. E.; Heckman, T. M.; Ptak, A. F.; Tremonti, C. A.; Colbert, E. J. M.

    2005-01-01

    We have cross-correlated X-ray catalogs derived from archival Chandra X-Ray Observatory ACIS observations with a Sloan Digital Sky Survey Data Release 2 (DR2) galaxy catalog to form a sample of 42 serendipitously X-ray-detected galaxies over the redshift interval 0.03X-ray-studied samples of normal galaxies and those in the deepest X-ray surveys. Our chief purpose is to compare optical spectroscopic diagnostics of activity (both star formation and accretion) with X-ray properties of galaxies. Our work supports a normalization value of the X-ray-star formation rate correlation consistent with the lower values published in the literature. The difference is in the allocation of X-ray emission to high-mass X-ray binaries relative to other components, such as hot gas, low-mass X-ray binaries, and/or active galactic nuclei (AGNs). We are able to quantify a few pitfalls in the use of lower resolution, lower signal-to-noise ratio optical spectroscopy to identify X-ray sources (as has necessarily been employed for many X-ray surveys). Notably, we find a few AGNs that likely would have been misidentified as non-AGN sources in higher redshift studies. However, we do not find any X-ray-hard, highly X-ray-luminous galaxies lacking optical spectroscopic diagnostics of AGN activity. Such sources are members of the ``X-ray-bright, optically normal galaxy'' (XBONG) class of AGNs.

  16. OSO 8 X-ray spectra of clusters of galaxies. II - Discussion

    NASA Technical Reports Server (NTRS)

    Smith, B. W.; Mushotzky, R. F.; Serlemitsos, P. J.

    1979-01-01

    An observational description of X-ray clusters of galaxies is given based on OSO 8 X-ray results for spatially integrated spectra of 20 such clusters and various correlations obtained from these results. It is found from a correlation between temperature and velocity dispersion that the X-ray core radius should be less than the galaxy core radius or, alternatively, that the polytropic index is about 1.1 for most of the 20 clusters. Analysis of a correlation between temperature and emission integral yields evidence that more massive clusters accumulate a larger fraction of their mass as intracluster gas. Galaxy densities and optical morphology, as they correlate with X-ray properties, are reexamined for indications as to how mass injection by galaxies affects the density structure of the gas. The physical arguments used to derive iron abundances from observed equivalent widths of iron line features in X-ray spectra are critically evaluated, and the associated uncertainties in abundances derived in this manner are estimated to be quite large.

  17. Recent X-ray Variability of Eta Car Approaching The X-ray Eclipse

    NASA Technical Reports Server (NTRS)

    Corcoran, M.; Swank, J. H.; Ishibashi, K.; Gull, T.; Humphreys, R.; Damineli, A.; Walborn, N.; Hillier, D. J.; Davidson, K.; White, S. M.

    2002-01-01

    We discuss recent X-ray spectral variability of the supermassive star Eta Car in the interval since the last X-ray eclipse in 1998. We concentrate on the interval just prior to the next X-ray eclipse which is expected to occur in June 2003. We compare the X-ray behavior during the 2001-2003 cycle with the previous cycle (1996-1998) and note similarities and differences in the temporal X-ray behavior. We also compare a recent X-ray observation of Eta Car obtained with the Chandra high energy transmission grating in October 2002 with an earlier observation from Nov 2002, and interpret these results in terms of the proposed colliding wind binary model for the star. In addition we discuss planned observations for the upcoming X-ray eclipse.

  18. Large area soft x-ray collimator to facilitate x-ray optics testing

    NASA Technical Reports Server (NTRS)

    Espy, Samuel L.

    1994-01-01

    The first objective of this program is to design a nested conical foil x-ray optic which will collimate x-rays diverging from a point source. The collimator could then be employed in a small, inexpensive x-ray test stand which would be used to test various x-ray optics and detector systems. The second objective is to demonstrate the fabrication of the x-ray reflectors for this optic using lacquer-smoothing and zero-stress electroforming techniques.

  19. Development of x-ray laminography under an x-ray microscopic condition

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoshino, Masato; Uesugi, Kentaro; Takeuchi, Akihisa

    2011-07-15

    An x-ray laminography system under an x-ray microscopic condition was developed to obtain a three-dimensional structure of laterally-extended planar objects which were difficult to observe by x-ray tomography. An x-ray laminography technique was introduced to an x-ray transmission microscope with zone plate optics. Three prototype sample holders were evaluated for x-ray imaging laminography. Layered copper grid sheets were imaged as a laminated sample. Diatomite powder on a silicon nitride membrane was measured to confirm the applicability of this method to non-planar micro-specimens placed on the membrane. The three-dimensional information of diatom shells on the membrane was obtained at a spatialmore » resolution of sub-micron. Images of biological cells on the membrane were also obtained by using a Zernike phase contrast technique.« less

  20. Laser plasma x-ray source for ultrafast time-resolved x-ray absorption spectroscopy

    DOE PAGES

    Miaja-Avila, L.; O'Neil, G. C.; Uhlig, J.; ...

    2015-03-02

    We describe a laser-driven x-ray plasma source designed for ultrafast x-ray absorption spectroscopy. The source is comprised of a 1 kHz, 20 W, femtosecond pulsed infrared laser and a water target. We present the x-ray spectra as a function of laser energy and pulse duration. Additionally, we investigate the plasma temperature and photon flux as we vary the laser energy. We obtain a 75 μm FWHM x-ray spot size, containing ~10 6 photons/s, by focusing the produced x-rays with a polycapillary optic. Since the acquisition of x-ray absorption spectra requires the averaging of measurements from >10 7 laser pulses, wemore » also present data on the source stability, including single pulse measurements of the x-ray yield and the x-ray spectral shape. In single pulse measurements, the x-ray flux has a measured standard deviation of 8%, where the laser pointing is the main cause of variability. Further, we show that the variability in x-ray spectral shape from single pulses is low, thus justifying the combining of x-rays obtained from different laser pulses into a single spectrum. Finally, we show a static x-ray absorption spectrum of a ferrioxalate solution as detected by a microcalorimeter array. Altogether, our results demonstrate that this water-jet based plasma source is a suitable candidate for laboratory-based time-resolved x-ray absorption spectroscopy experiments.« less

  1. Hard X-Ray Lightcurves of High Mass X-Ray Binaries

    NASA Technical Reports Server (NTRS)

    Laycock, S.; Coe, M. J.; Harmon, B. A.; Finger, M.; Wilson-Hodge, C.; Rose, M. Franklin (Technical Monitor)

    2001-01-01

    Using the 7.2 years of continuous data now available from the Burst And Transient Source Experiment (BATSE) aboard CGRO, we have measured orbital periods and produced folded lightcurves for 8 High Mass X-ray Binaries (HMXB). Given the length of the datasets, our determinations are based on many more binary orbits than previous investigations. Thus our source detections have high statistical significance and we are able to follow long-term trends in X-ray output. In particular we focus on two systems: A0538-668 and EXO2030+375 both HMXBs exhibiting Type I outbursts. Recent work on A0538-668 (Alcock et al 1999) reported a 16.65d optical variability due to the orbital period, but only seen during minima of a longer-term variability at 421d. We searched for this signal in the BATSE dataset using an ephemeris derived from Alcock et al ( 1999) & Skinner ( 1982). We found no evidence for such modulation and place an upper limit of 3.0 x 10(exp -3) photon/sq cm.s in the 20-70 keV BATSE energy band , based upon statistical modelling of the signal. EXO2030+375 has exhibited an X-ray active epoch, followed by a quiescent period lasting 2.5yr and since April 1996 has exhibited renewed activity. Previous observations (Reig et a 1998) using RXTE ASM data indicate secondary outbursts occur at apastron passage during the current epoch, but not in the former. We present a lightcurve for the earlier epoch showing convincing evidence for such apastron outbursts. We find apastron outbursts in 3 sources, all having orbital periods greater than 41d. No such signal is conclusively detected in the more rapidly orbiting systems studied.

  2. Panoramic Dental X-Ray

    MedlinePlus

    ... Physician Resources Professions Site Index A-Z Panoramic Dental X-ray Panoramic dental x-ray uses a very small dose of ... x-ray , is a two-dimensional (2-D) dental x-ray examination that captures the entire mouth ...

  3. Use of fast neutrons for assessing sarcopenia by measuring body phosphorus: relevance to health and quality of life of the elderly

    NASA Astrophysics Data System (ADS)

    Kehayias, Joseph J.; Zhuang, Hong; Doherty, Patricia L.

    1997-02-01

    Sarcopenia, defined as the loss of skeletal muscle with age, may lead to frailty, fractures due to falls, and reduced immunity to disease. By understanding the causes of muscle loss with age we will be able to develop ways of maintaining functional capacity and quality of life for the elderly. Elemental Partition Analysis (EPA) is a new approach to body composition assessment. A major element of the body is measured and then, by means of other measurements, is partitioned to the contributing body compartments. We developed a model for measuring total body muscle by applying the EPA method to total body phosphorus (TBP). We measure TBP by in vivo fast neutron activation analysis using the reaction 31P(n,(alpha) )28Al. The main contributors to TBP are bone and skeletal muscle. Adipose tissue and the liver contribute less than 3 percent. We use dual-energy x-ray absorptiometry (DXA) to evaluate the contribution of bone to TBP. COrrections are applied for the small contributions of the liver and adipose tissue to TBP to derive muscle phosphorus. The technique requires high precision measurements for both TBP and DXA. The total body radiation exposure for measuring human subjects is 0.30 mSv.

  4. Nanofocusing with aberration-corrected rotationally parabolic refractive X-ray lenses

    DOE PAGES

    Seiboth, Frank; Wittwer, Felix; Scholz, Maria; ...

    2018-01-01

    Wavefront errors of rotationally parabolic refractive X-ray lenses made of beryllium (Be CRLs) have been recovered for various lens sets and X-ray beam configurations. Due to manufacturing via an embossing process, aberrations of individual lenses within the investigated ensemble are very similar. By deriving a mean single-lens deformation for the ensemble, aberrations of any arbitrary lens stack can be predicted from the ensemble with σ¯ = 0.034λ. Using these findings the expected focusing performance of current Be CRLs are modeled for relevant X-ray energies and bandwidths and it is shown that a correction of aberrations can be realised without priormore » lens characterization but simply based on the derived lens deformation. As a result, the performance of aberration-corrected Be CRLs is discussed and the applicability of aberration-correction demonstrated over wide X-ray energy ranges.« less

  5. X-ray, UV and optical analysis of supergiants: ɛ Ori

    NASA Astrophysics Data System (ADS)

    Puebla, Raul E.; Hillier, D. John; Zsargó, Janos; Cohen, David H.; Leutenegger, Maurice A.

    2016-03-01

    We present a multi-wavelength (X-ray to optical) analysis, based on non-local thermodynamic equilibrium photospheric+wind models, of the B0 Ia-supergiant: ɛ Ori. The aim is to test the consistency of physical parameters, such as the mass-loss rate and CNO abundances, derived from different spectral bands. The derived mass-loss rate is {dot {M}} / {√{f_{∞}}} {˜} 1.6 × 10-6 M⊙ yr-1 where f∞ is the volume filling factor. However, the S IV λλ1062,1073 profiles are too strong in the models; to fit the observed profiles it is necessary to use f∞ <0.01. This value is a factor of 5 to 10 lower than inferred from other diagnostics, and implies {dot{M}} ≲ 1 × 10^{-7} M⊙ yr-1. The discrepancy could be related to porosity-vorosity effects or a problem with the ionization of sulphur in the wind. To fit the UV profiles of N V and O VI it was necessary to include emission from an interclump medium with a density contrast (ρcl/ρICM) of ˜100. X-ray emission in H/He like and Fe L lines was modelled using four plasma components located within the wind. We derive plasma temperatures from 1 × 106 to 7 × 106 K, with lower temperatures starting in the outer regions (R0 ˜ 3-6 R*), and a hot component starting closer to the star (R0 ≲ 2.9 R*). From X-ray line profiles we infer {dot{M}} < 4.9 × 10-7 M⊙ yr-1. The X-ray spectrum (≥0.1 kev) yields an X-ray luminosity LX ˜ 2.0 × 10-7Lbol, consistent with the superion line profiles. X-ray abundances are in agreement with those derived from the UV and optical analysis: ɛ Ori is slightly enhanced in nitrogen and depleted in carbon and oxygen, evidence for CNO processed material.

  6. Discovery and development of x-ray diffraction

    NASA Astrophysics Data System (ADS)

    Jeong, Yeuncheol; Yin, Ming; Datta, Timir

    2013-03-01

    In 1912 Max Laue at University of Munich reasoned x-rays to be short wavelength electromagnetic waves and figured interference would occur when scattered off crystals. Arnold Sommerfeld, W. Wien, Ewald and others, raised objections to Laue's idea, but soon Walter Friedrich succeeded in recording x-ray interference patterns off copper sulfate crystals. But the Laue-Ewald's 3-dimensional formula predicted excess spots. Fewer spots were observed. William Lawrence Bragg then 22 year old studying at Cambridge University heard the Munich results from father William Henry Brag, physics professor at Univ of Leeds. Lawrence figured the spots are 2-d interference of x-ray wavelets reflecting off successive atomic planes and derived a simple eponymous equation, the Bragg equation d*sin(theta) = n*lamda. 1913 onward the Braggs dominated the crystallography. Max Laue was awarded the physics Nobel in 1914 and the Braggs shared the same in 1915. Starting with Rontgen's first ever prize in 1901, the importance of x-ray techniques is evident from the four out of a total 16 physics Nobels between 1901-1917. We will outline the historical back ground and importance of x-ray diffraction giving rise to techniques that even in 2013, remain work horses in laboratories all over the globe.

  7. The Swift Supergiant Fast X-ray Transient Project

    NASA Astrophysics Data System (ADS)

    Romano, P.; Barthelmy, S.; Bozzo, E.; Burrows, D.; Ducci, L.; Esposito, P.; Evans, P.; Kennea, J.; Krimm, H.; Vercellone, S.

    2017-10-01

    We present the Swift Supergiant Fast X-ray Transients project, a systematic study of SFXTs and classical supergiant X-ray binaries (SGXBs) through efficient long-term monitoring of 17 sources including SFXTs and classical SGXBs across more than 4 orders of magnitude in X-ray luminosity on timescales from hundred seconds to years. We derived dynamic ranges, duty cycles, and luminosity distributions to highlight systematic differences that help discriminate between different theoretical models proposed to explain the differences between the wind accretion processes in SFXTs and classical SGXBs. Our follow-ups of the SFXT outbursts provide a steady advancement in the comprehension of the mechanisms triggering the high X-ray level emission of these sources. In particular, the observations of the outburst of the SFXT prototype IGR J17544-2619, when the source reached a peak X-ray luminosity of 3×10^{38} erg s^{-1}, challenged for the first time the maximum theoretical luminosity achievable by a wind-fed neutron star high mass X-ray binary. We propose that this giant outburst was due to the formation of a transient accretion disc around the compact object. We also created a catalogue of over 1000 BAT flares which we use to predict the observability and perspectives with future missions.

  8. Construction and validation of a population-based bone densitometry database.

    PubMed

    Leslie, William D; Caetano, Patricia A; Macwilliam, Leonard R; Finlayson, Gregory S

    2005-01-01

    Utilization of dual-energy X-ray absorptiometry (DXA) for the initial diagnostic assessment of osteoporosis and in monitoring treatment has risen dramatically in recent years. Population-based studies of the impact of DXA and osteoporosis remain challenging because of incomplete and fragmented test data that exist in most regions. Our aim was to create and assess completeness of a database of all clinical DXA services and test results for the province of Manitoba, Canada and to present descriptive data resulting from testing. A regionally based bone density program for the province of Manitoba, Canada was established in 1997. Subsequent DXA services were prospectively captured in a program database. This database was retrospectively populated with earlier DXA results dating back to 1990 (the year that the first DXA scanner was installed) by integrating multiple data sources. A random chart audit was performed to assess completeness and accuracy of this dataset. For comparison, testing rates determined from the DXA database were compared with physician administrative claims data. There was a high level of completeness of this database (>99%) and accurate personal identifier information sufficient for linkage with other health care administrative data (>99%). This contrasted with physician billing data that were found to be markedly incomplete. Descriptive data provide a profile of individuals receiving DXA and their test results. In conclusion, the Manitoba bone density database has great potential as a resource for clinical and health policy research because it is population based with a high level of completeness and accuracy.

  9. X-ray Spectral Formation In High-mass X-ray Binaries: The Case Of Vela X-1

    NASA Astrophysics Data System (ADS)

    Akiyama, Shizuka; Mauche, C. W.; Liedahl, D. A.; Plewa, T.

    2007-05-01

    We are working to develop improved models of radiatively-driven mass flows in the presence of an X-ray source -- such as in X-ray binaries, cataclysmic variables, and active galactic nuclei -- in order to infer the physical properties that determine the X-ray spectra of such systems. The models integrate a three-dimensional time-dependent hydrodynamics capability (FLASH); a comprehensive and uniform set of atomic data, improved calculations of the line force multiplier that account for X-ray photoionization and non-LTE population kinetics, and X-ray emission-line models appropriate to X-ray photoionized plasmas (HULLAC); and a Monte Carlo radiation transport code that simulates Compton scattering and recombination cascades following photoionization. As a test bed, we have simulated a high-mass X-ray binary with parameters appropriate to Vela X-1. While the orbital and stellar parameters of this system are well constrained, the physics of X-ray spectral formation is less well understood because the canonical analytical wind velocity profile of OB stars does not account for the dynamical and radiative feedback effects due to the rotation of the system and to the irradiation of the stellar wind by X-rays from the neutron star. We discuss the dynamical wind structure of Vela X-1 as determined by the FLASH simulation, where in the binary the X-ray emission features originate, and how the spatial and spectral properties of the X-ray emission features are modified by Compton scattering, photoabsorption, and fluorescent emission. This work was performed under the auspices of the U.S. Department of Energy by University of California, Lawrence Livermore National Laboratory under Contract W-7405-Eng-48.

  10. X-ray beam finder

    DOEpatents

    Gilbert, H.W.

    1983-06-16

    An X-ray beam finder for locating a focal spot of an X-ray tube includes a mass of X-ray opaque material having first and second axially-aligned, parallel-opposed faces connected by a plurality of substantially identical parallel holes perpendicular to the faces and a film holder for holding X-ray sensitive film tightly against one face while the other face is placed in contact with the window of an X-ray head.

  11. X-ray imaging crystal spectrometer for extended X-ray sources

    DOEpatents

    Bitter, Manfred L.; Fraenkel, Ben; Gorman, James L.; Hill, Kenneth W.; Roquemore, A. Lane; Stodiek, Wolfgang; von Goeler, Schweickhard E.

    2001-01-01

    Spherically or toroidally curved, double focusing crystals are used in a spectrometer for X-ray diagnostics of an extended X-ray source such as a hot plasma produced in a tokomak fusion experiment to provide spatially and temporally resolved data on plasma parameters using the imaging properties for Bragg angles near 45. For a Bragg angle of 45.degree., the spherical crystal focuses a bundle of near parallel X-rays (the cross section of which is determined by the cross section of the crystal) from the plasma to a point on a detector, with parallel rays inclined to the main plain of diffraction focused to different points on the detector. Thus, it is possible to radially image the plasma X-ray emission in different wavelengths simultaneously with a single crystal.

  12. X-ray lithography source

    DOEpatents

    Piestrup, M.A.; Boyers, D.G.; Pincus, C.

    1991-12-31

    A high-intensity, inexpensive X-ray source for X-ray lithography for the production of integrated circuits is disclosed. Foil stacks are bombarded with a high-energy electron beam of 25 to 250 MeV to produce a flux of soft X-rays of 500 eV to 3 keV. Methods of increasing the total X-ray power and making the cross section of the X-ray beam uniform are described. Methods of obtaining the desired X-ray-beam field size, optimum frequency spectrum and eliminating the neutron flux are all described. A method of obtaining a plurality of station operation is also described which makes the process more efficient and economical. The satisfying of these issues makes transition radiation an excellent moderate-priced X-ray source for lithography. 26 figures.

  13. X-ray lithography source

    DOEpatents

    Piestrup, Melvin A.; Boyers, David G.; Pincus, Cary

    1991-01-01

    A high-intensity, inexpensive X-ray source for X-ray lithography for the production of integrated circuits. Foil stacks are bombarded with a high-energy electron beam of 25 to 250 MeV to produce a flux of soft X-rays of 500 eV to 3 keV. Methods of increasing the total X-ray power and making the cross section of the X-ray beam uniform are described. Methods of obtaining the desired X-ray-beam field size, optimum frequency spectrum and elminating the neutron flux are all described. A method of obtaining a plurality of station operation is also described which makes the process more efficient and economical. The satisfying of these issues makes transition radiation an exellent moderate-priced X-ray source for lithography.

  14. A coordinated X-ray, optical, and microwave study of the flare star Proxima Centauri

    NASA Technical Reports Server (NTRS)

    Haisch, B. M.; Linsky, J. L.; Slee, O. B.; Hearn, D. R.; Walker, A. R.; Rydgren, A. E.; Nicolson, G. D.

    1978-01-01

    Results are reported for a three-day coordinated observing program to monitor the flare star Proxima Centauri in the X-ray, optical, and radio spectrum. During this interval 30 optical flares and 12 possible radio bursts were observed. The SAS 3 X-ray satellite made no X-ray detections. An upper limit of 0.08 on the X-ray/optical luminosity ratio is derived for the brightest optical flare. The most sensitive of the radio telescopes failed to detect 6-cm emission during one major and three minor optical flares, and on this basis an upper limit on the flare radio emission (1 hundred-thousandth of the optimal luminosity) is derived.

  15. Bone cartilage imaging with x-ray interferometry using a practical x-ray tube

    NASA Astrophysics Data System (ADS)

    Kido, Kazuhiro; Makifuchi, Chiho; Kiyohara, Junko; Itou, Tsukasa; Honda, Chika; Momose, Atsushi

    2010-04-01

    The purpose of this study was to design an X-ray Talbot-Lau interferometer for the imaging of bone cartilage using a practical X-ray tube and to develop that imaging system for clinical use. Wave-optics simulation was performed to design the interferometer with a practical X-ray tube, a source grating, two X-ray gratings, and an X-ray detector. An imaging system was created based on the results of the simulation. The specifications were as follows: the focal spot size was 0.3 mm of an X-ray tube with a tungsten anode (Toshiba, Tokyo, Japan). The tube voltage was set at 40 kVp with an additive aluminum filter, and the mean energy was 31 keV. The pixel size of the X-ray detector, a Condor 486 (Fairchild Imaging, California, USA), was 15 μm. The second grating was a Ronchi-type grating whose pitch was 5.3 μm. Imaging performance of the system was examined with X-ray doses of 0.5, 3 and 9 mGy so that the bone cartilage of a chicken wing was clearly depicted with X-ray doses of 3 and 9 mGy. This was consistent with the simulation's predictions. The results suggest that X-ray Talbot-Lau interferometry would be a promising tool in detecting soft tissues in the human body such as bone cartilage for the X-ray image diagnosis of rheumatoid arthritis. Further optimization of the system will follow to reduce the X-ray dose for clinical use.

  16. Bandpass x-ray diode and x-ray multiplier detector

    DOEpatents

    Wang, C.L.

    1982-09-27

    An absorption-edge of an x-ray absorption filter and a quantum jump of a photocathode determine the bandpass characteristics of an x-ray diode detector. An anode, which collects the photoelectrons emitted by the photocathode, has enhanced amplification provided by photoelectron-multiplying means which include dynodes or a microchannel-plate electron-multiplier. Suppression of undesired high frequency response for a bandpass x-ray diode is provided by subtracting a signal representative of energies above the passband from a signal representative of the overall response of the bandpass diode.

  17. X-ray astronomical spectroscopy

    NASA Technical Reports Server (NTRS)

    Holt, Stephen S.

    1987-01-01

    The contributions of the Goddard group to the history of X-ray astronomy are numerous and varied. One role that the group has continued to play involves the pursuit of techniques for the measurement and interpretation of the X-ray spectra of cosmic sources. The latest development is the selection of the X-ray microcalorimeter for the Advanced X-ray Astrophysics Facility (AXAF) study payload. This technology is likely to revolutionize the study of cosmic X-ray spectra.

  18. Operational properties of fluctuation X-ray scattering data

    DOE PAGES

    Malmerberg, Erik; Kerfeld, Cheryl A.; Zwart, Petrus H.

    2015-03-20

    X-ray scattering images collected on timescales shorter than rotation diffusion times using a (partially) coherent beam result in a significant increase in information content in the scattered data. These measurements, named fluctuation X-ray scattering (FXS), are typically performed on an X-ray free-electron laser (XFEL) and can provide fundamental insights into the structure of biological molecules, engineered nanoparticles or energy-related mesoscopic materials beyond what can be obtained with standard X-ray scattering techniques. In order to understand, use and validate experimental FXS data, the availability of basic data characteristics and operational properties is essential, but has been absent up to this point.more » In this communication, an intuitive view of the nature of FXS data and their properties is provided, the effect of FXS data on the derived structural models is highlighted, and generalizations of the Guinier and Porod laws that can ultimately be used to plan experiments and assess the quality of experimental data are presented.« less

  19. Resolution dependence of petrophysical parameters derived from X-ray tomography of chalk

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Müter, D.; Sørensen, H. O.; Jha, D.

    2014-07-28

    X-ray computed tomography data from chalk drill cuttings were taken over a series of voxel dimensions, ranging from 320 to 25 nm. From these data sets, standard petrophysical parameters (porosity, surface area, and permeability) were derived and we examined the effect of the voxel dimension (i.e., image resolution) on these properties. We found that for the higher voxel dimensions, they are severely over or underestimated, whereas for 50 and 25 nm voxel dimension, the resulting values (5%–30% porosity, 0.2–2 m{sup 2}/g specific surface area, and 0.06–0.34 mD permeability) are within the expected range for this type of rock. We compared our resultsmore » to macroscopic measurements and in the case of surface area, also to measurements using the Brunauer-Emmett-Teller (BET) method and found that independent of the degree of compaction, the results from tomography amount to about 30% of the BET method. Finally, we concluded that at 25 nm voxel dimension, the essential features of the nanoscopic pore network in chalk are captured but better resolution is still needed to derive surface area.« less

  20. Technology Requirements For a Square-Meter, Arcsecond-Resolution Telescope for X-Rays: The SMART-X Mission

    NASA Technical Reports Server (NTRS)

    Schwartz, Daniel A.; Allured, Ryan; Bookbinder, Jay; Cotroneo, Vincenzo; Forman, William; Freeman, Mark; McMuldroch, Stuart; Reid, Paul; Tananbaum, Harvey; Vikhlinin, Alexey; hide

    2014-01-01

    Addressing the astrophysical problems of the 2020's requires sub-arcsecond x-ray imaging with square meter effective area. Such requirements can be derived, for example, by considering deep x-ray surveys to find the young black holes in the early universe (large redshifts) which will grow into the first supermassive black holes. We have envisioned a mission based on adjustable x-ray optics technology, in order to achieve the required reduction of mass to collecting area for the mirrors. We are pursuing technology which effects this adjustment via thin film piezoelectric "cells" deposited directly on the non-reflecting sides of thin, slumped glass. While SMARTX will also incorporate state-of-the-art x-ray cameras, the remaining spacecraft systems have no more stringent requirements than those which are well understood and proven on the current Chandra X-ray Observatory.

  1. X-Ray

    MedlinePlus

    ... of gray. For some types of X-ray tests, a contrast medium — such as iodine or barium — is introduced into your body to provide greater detail on the images. Why it's done X-ray technology is used to examine many parts of the ...

  2. X-ray luminescence computed tomography using a focused x-ray beam.

    PubMed

    Zhang, Wei; Lun, Michael C; Nguyen, Alex Anh-Tu; Li, Changqing

    2017-11-01

    Due to the low x-ray photon utilization efficiency and low measurement sensitivity of the electron multiplying charge coupled device camera setup, the collimator-based narrow beam x-ray luminescence computed tomography (XLCT) usually requires a long measurement time. We, for the first time, report a focused x-ray beam-based XLCT imaging system with measurements by a single optical fiber bundle and a photomultiplier tube (PMT). An x-ray tube with a polycapillary lens was used to generate a focused x-ray beam whose x-ray photon density is 1200 times larger than a collimated x-ray beam. An optical fiber bundle was employed to collect and deliver the emitted photons on the phantom surface to the PMT. The total measurement time was reduced to 12.5 min. For numerical simulations of both single and six fiber bundle cases, we were able to reconstruct six targets successfully. For the phantom experiment, two targets with an edge-to-edge distance of 0.4 mm and a center-to-center distance of 0.8 mm were successfully reconstructed by the measurement setup with a single fiber bundle and a PMT. (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).

  3. SPECTRAL SURVEY OF X-RAY BRIGHT ACTIVE GALACTIC NUCLEI FROM THE ROSSI X-RAY TIMING EXPLORER

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rivers, Elizabeth; Markowitz, Alex; Rothschild, Richard, E-mail: erivers@ucsd.edu

    2011-03-15

    Using long-term monitoring data from the Rossi X-ray Timing Explorer (RXTE), we have selected 23 active galactic nuclei (AGNs) with sufficient brightness and overall observation time to derive broadband X-ray spectra from 3 to {approx}>100 keV. Our sample includes mainly radio-quiet Seyferts, as well as seven radio-loud sources. Given the longevity of the RXTE mission, the greater part of our data is spread out over more than a decade, providing truly long-term average spectra and eliminating inconsistencies arising from variability. We present long-term average values of absorption, Fe line parameters, Compton reflection strengths, and photon indices, as well as fluxesmore » and luminosities for the hard and very hard energy bands, 2-10 keV and 20-100 keV, respectively. We find tentative evidence for high-energy rollovers in three of our objects. We improve upon previous surveys of the very hard X-ray energy band in terms of accuracy and sensitivity, particularly with respect to confirming and quantifying the Compton reflection component. This survey is meant to provide a baseline for future analysis with respect to the long-term averages for these sources and to cement the legacy of RXTE, and especially its High Energy X-ray Timing Experiment, as a contributor to AGN spectral science.« less

  4. X-ray Observations of Cosmic Ray Acceleration

    NASA Technical Reports Server (NTRS)

    Petre, Robert

    2012-01-01

    Since the discovery of cosmic rays, detection of their sources has remained elusive. A major breakthrough has come through the identification of synchrotron X-rays from the shocks of supernova remnants through imaging and spectroscopic observations by the most recent generation of X-ray observatories. This radiation is most likely produced by electrons accelerated to relativistic energy, and thus has offered the first, albeit indirect, observational evidence that diffusive shock acceleration in supernova remnants produces cosmic rays to TeV energies, possibly as high as the "knee" in the cosmic ray spectrum. X-ray observations have provided information about the maximum energy to which these shOCks accelerate electrons, as well as indirect evidence of proton acceleration. Shock morphologies measured in X-rays have indicated that a substantial fraction of the shock energy can be diverted into particle acceleration. This presentation will summarize what we have learned about cosmic ray acceleration from X-ray observations of supernova remnants over the past two decades.

  5. Optimizing Bone Health in Duchenne Muscular Dystrophy.

    PubMed

    Buckner, Jason L; Bowden, Sasigarn A; Mahan, John D

    2015-01-01

    Duchenne muscular dystrophy (DMD) is an X-linked recessive disorder characterized by progressive muscle weakness, with eventual loss of ambulation and premature death. The approved therapy with corticosteroids improves muscle strength, prolongs ambulation, and maintains pulmonary function. However, the osteoporotic impact of chronic corticosteroid use further impairs the underlying reduced bone mass seen in DMD, leading to increased fragility fractures of long bones and vertebrae. These serious sequelae adversely affect quality of life and can impact survival. The current clinical issues relating to bone health and bone health screening methods in DMD are presented in this review. Diagnostic studies, including biochemical markers of bone turnover and bone mineral density by dual energy X-ray absorptiometry (DXA), as well as spinal imaging using densitometric lateral spinal imaging, and treatment to optimize bone health in patients with DMD are discussed. Treatment with bisphosphonates offers a method to increase bone mass in these children; oral and intravenous bisphosphonates have been used successfully although treatment is typically reserved for children with fractures and/or bone pain with low bone mass by DXA.

  6. A Catalog of Candidate Intermediate-Luminosity X-Ray Objects

    NASA Astrophysics Data System (ADS)

    Colbert, E. J. M.; Ptak, A. F.

    2002-11-01

    ROSAT, and now Chandra, X-ray images allow studies of extranuclear X-ray point sources in galaxies other than our own. X-ray observations of normal galaxies with ROSAT and Chandra have revealed that off-nuclear, compact, intermediate-luminosity (LX[2-10keV]>=1039.0 ergs s-1) X-ray objects (IXOs, a.k.a. ULXs [ultraluminous X-ray sources]) are quite common. Here we present a catalog and finding charts for 87 IXOs in 54 galaxies, derived from all of the ROSAT HRI imaging data for galaxies with cz<=5000 km s-1 from the Third Reference Catalog of Bright Galaxies. We have defined the cutoff LX for IXOs so that it is well above the Eddington luminosity of a 1.4 Msolar black hole (1038.3 ergs s-1), so as not to confuse IXOs with ``normal'' black hole X-ray binaries. This catalog is intended to provide a baseline for follow-up work with Chandra and XMM-Newton, and with space- and ground-based survey work at wavelengths other than X-ray. We demonstrate that elliptical galaxies with IXOs have a larger number of IXOs per galaxy than nonelliptical galaxies with IXOs and note that they are not likely to be merely high-mass X-ray binaries with beamed X-ray emission, as may be the case for IXOs in starburst galaxies. Approximately half of the IXOs with multiple observations show X-ray variability, and many (19) of the IXOs have faint optical counterparts in DSS optical B-band images. Follow-up observations of these objects should be helpful in identifying their nature.

  7. X-rays from the colliding wind binary WR 146

    NASA Astrophysics Data System (ADS)

    Zhekov, Svetozar A.

    2017-12-01

    The X-ray emission from the massive Wolf-Rayet binary (WR 146 ) is analysed in the framework of the colliding stellar wind (CSW) picture. The theoretical CSW model spectra match well the shape of the observed X-ray spectrum of WR 146, but they overestimate considerably the observed X-ray flux (emission measure). This is valid in the case of both complete temperature equalization and partial electron heating at the shock fronts (different electron and ion temperatures), but there are indications for a better correspondence between model predictions and observations for the latter. To reconcile the model predictions and observations, the mass-loss rate of WR 146 must be reduced by a factor of 8-10 compared to the currently accepted value for this object (the latter already takes clumping into account). No excess X-ray absorption is derived from the CSW modelling.

  8. The diversity of soft X-ray spectra in quasars

    NASA Technical Reports Server (NTRS)

    Elvis, M.; Wilkes, B. J.; Tananbaum, H.

    1985-01-01

    Soft X-ray spectra for three quasars obtained with the Einstein Imaging Proportional Counter covering the 0.1-4.0 keV band are reported. Power-law fits to these spectra have best-fit energy indices of 1.2 +0.6 or -0.2, for the quasar NAB 0205 + 024, 0.6 +0.3 or -0.2 for the quasar B2 1028 + 313, and 2.2 + or -0.4 for the quasar PG 1211 + 143. None of the quasars shows any evidence for a column density of cold matter in excess of the galactic values. The derived spectra demonstrate that there is no single universal power law slope for quasar X-ray spectra. The implications of these results for the X-ray background, X-ray continuum emission mechanisms, and the production of the optical/UV emission lines are briefly discussed.

  9. Method for spatially modulating X-ray pulses using MEMS-based X-ray optics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lopez, Daniel; Shenoy, Gopal; Wang, Jin

    A method and apparatus are provided for spatially modulating X-rays or X-ray pulses using microelectromechanical systems (MEMS) based X-ray optics. A torsionally-oscillating MEMS micromirror and a method of leveraging the grazing-angle reflection property are provided to modulate X-ray pulses with a high-degree of controllability.

  10. X-ray monitoring optical elements

    DOEpatents

    Stoupin, Stanislav; Shvydko, Yury; Katsoudas, John; Blank, Vladimir D.; Terentyev, Sergey A.

    2016-12-27

    An X-ray article and method for analyzing hard X-rays which have interacted with a test system. The X-ray article is operative to diffract or otherwise process X-rays from an input X-ray beam which have interacted with the test system and at the same time provide an electrical circuit adapted to collect photoelectrons emitted from an X-ray optical element of the X-ray article to analyze features of the test system.

  11. The Distance and Mass of the Galaxy Cluster Abell 1995 Derived from Sunyaev-Zeldovich Effect and X-Ray Measurements

    NASA Technical Reports Server (NTRS)

    Patel, Sandeep K.; Joy, Marshall; Carlstrom, John E.; Holder, Gilbert P.; Reese, Erik D.; Gomez, Percy L.; Hughes, John P.; Grego, Laura; Holzapfel, William L.

    2000-01-01

    We present multiwavelength observations of the Abell 1995 galaxy cluster. From an analysis of X-ray spectroscopy and imaging data, we derive the electron temperature, cluster core radius, and central electron number density. Using optical spectroscopy of 15 cluster members, we derive an accurate cluster redshift and velocity dispersion. Finally, the interferometric imaging of the Sunyaev-Zeldovich effect toward Abell 1995 at 28.5 GHz provides a measure of the integrated pressure through the cluster. The X-ray and Sunyaev-Zeldovich effect observations are combined to determine the angular diameter distance to the cluster of D(sub A) = 1294(sup +294 +438, sub -283 -458) Mpc (Statistical followed by systematic uncertainty), implying a Hubble constant of H(sub 0) = 52.2(sup +11.4 +18.5, sub -11.9 -17.7) km/s.Mpc for Omega(sub M) = 0.3 and Omega(sub lambda) = 0.7. We find a best-fit H(sub 0) of 46 km/s.Mpc for the Omega(sub M) = 1 and Omega(sub lambda) = 0 cosmology, and 48 km/s.Mpc for Omega(sub M) = 0.3 and Omega(sub lambda) = 0.0. The X-ray data are also used to derive a total cluster mass of M(sup HSE, sub tot)(r(sub 500)) = 5.18(sup +0.62, sub -0.48) x 10(exp 14)/h solar mass; the optical velocity dispersion yields an independent and consistent estimate of M(sup virial, sub tot)(r(sub 500)) = 6.35(sup +1.51, sub -1.19) X 10(exp 14) /h solar mass. Both of the total mass estimates are evaluated at a fiducial radius, r(sub 500) = 830 /h kpc, where the overdensity is 500 times the critical density. The total cluster mass is then combined with gas mass measurements to determine a cluster gas mass fraction of F(sub g) = 0.056(sup +0.010, sub -0.013) /h(sup 3/2) in combination with recent baryon density constraints, the measured gas mass fraction yields an upper limit on the mass density parameter of Omega(sub M) h(sup 1/2) <= 0.34(sup +/0.06, sub 0.05.

  12. Optical and X-ray studies of Compact X-ray Binaries in NGC 5904

    NASA Astrophysics Data System (ADS)

    Bhalotia, Vanshree; Beck-Winchatz, Bernhard

    2018-06-01

    Due to their high stellar densities, globular cluster systems trigger various dynamical interactions, such as the formation of compact X-ray binaries. Stellar collisional frequencies have been correlated to the number of X-ray sources detected in various clusters and we hope to measure this correlation for NGC 5904. Optical fluxes of sources from archival HST images of NGC 5904 have been measured using a DOLPHOT PSF photometry in the UV, optical and near-infrared. We developed a data analysis pipeline to process the fluxes of tens of thousands of objects using awk, python and DOLPHOT. We plot color magnitude diagrams in different photometric bands in order to identify outliers that could be X-ray binaries, since they do not evolve the same way as singular stars. Aligning previously measured astrometric data for X-ray sources in NGC 5904 from Chandra with archival astrometric data from HST will filter out the outlier objects that are not X-ray producing, and provide a sample of compact binary systems that are responsible for X-ray emission in NGC 5904. Furthermore, previously measured X-ray fluxes of NGC 5904 from Chandra have also been used to measure the X-ray to optical flux ratio and identify the types of compact X-ray binaries responsible for the X-ray emissions in NGC 5904. We gratefully acknowledge the support from the Illinois Space Grant Consortium.

  13. Low body mass index can identify majority of osteoporotic inflammatory bowel disease patients missed by current guidelines.

    PubMed

    Atreja, Ashish; Aggarwal, Ashish; Licata, Angelo A; Lashner, Bret A

    2012-01-01

    Patients with inflammatory bowel disease (IBD) are at high risk of developing osteoporosis. Our objective was to determine the usefulness of IBD guidelines in identifying patients at risk for developing osteoporosis. We utilized institutional repository to identify patients seen in IBD center and extracted data on demographics, disease history, conventional, and nonconventional risk factors for osteoporosis and Dual Energy X-ray Absorptiometry (DXA) findings. 59% of patients (1004/1703) in our IBD cohort had at least one risk factor for osteoporosis screening. DXA was documented in 263 patients with indication of screening (provider adherence, 26.2%), and of these, 196 patients had DXA completed ("at-risk" group). Ninety-five patients not meeting guidelines-based risk factors also had DXA completed ("not at-risk" group). 139 (70.9%) patients in "at-risk" group had low BMD, while 51 (53.7%) of "not-at-risk" patients had low BMD. Majority of the patients with osteoporosis (83.3%) missed by the current guidelines had low BMI. Multivariate logistic regression analysis showed that low BMI was the strongest risk factor for osteoporosis (OR 3.07; 95% CI, 1.47-6.42; P = 0.003). Provider adherence to current guidelines is suboptimal. Low BMI can identify majority of the patients with osteoporosis that are missed by current guidelines.

  14. Predicting fat-free mass in children using bioimpedance analysis.

    PubMed

    Pietrobelli, A; Andreoli, A; Cervelli, V; Carbonelli, M G; Peroni, D G; De Lorenzo, A

    2003-10-01

    Body composition assessment is a useful procedure for the study of nutritional status and water distribution. In adults, it is a predictor of morbidity and mortality, since body fatness is associated with risk factors for cardiovascular disease. Bioelectric impedance analysis (BIA) is a simple, safe, and inexpensive method for assessment of body composition both in pediatric and adult subjects. The aim of our study was to validate the impedance index, ZI (H(2)/Z, height in cm(2)/impedance), as a predictor factor of fatfree mass (FFM) and fat mass (FM) in a sample ( n=75) of normal children. Dual-energy X-ray absorptiometry (DXA) was chosen as reference method. Despite some minor bias, DXAis considerably less expensive and easier to administer in pediatric subjects than other established gold standard reference methods for assessing body composition. ZI values were highly correlated with FFM measured with DXA. The following equations were obtained from the regression analysis: (a). male subjects, FFM(DXA)=0.6375 (ZI)+5.9913, r(2)=0.897, p<0.0001; (b). female subjects, FFM(DXA)=0.7597 (ZI)+ 3.5853, r(2)=0.903, p<0.0001. These data support the notion that BIA alone can be used as a surrogate to measure FFM in a pediatric sample.

  15. Energy dependence measurement of small-type optically stimulated luminescence (OSL) dosimeter by means of characteristic X-rays induced with general diagnostic X-ray equipment.

    PubMed

    Takegami, Kazuki; Hayashi, Hiroaki; Okino, Hiroki; Kimoto, Natsumi; Maehata, Itsumi; Kanazawa, Yuki; Okazaki, Tohru; Hashizume, Takuya; Kobayashi, Ikuo

    2016-01-01

    For X-ray inspections by way of general X-ray equipment, it is important to measure an entrance-skin dose. Recently, a small optically stimulated luminescence (OSL) dosimeter was made commercially available by Landauer, Inc. The dosimeter does not interfere with the medical images; therefore, it is expected to be a convenient detector for measuring personal exposure doses. In an actual clinical situation, it is assumed that X-rays of different energies will be detected by a dosimeter. For evaluation of the exposure dose measured by a dosimeter, it is necessary to know the energy dependence of the dosimeter. Our aim in this study was to measure the energy dependence of the OSL dosimeter experimentally in the diagnostic X-ray region. Metal samples weighing several grams were irradiated and, in this way, characteristic X-rays having energies ranging from 8 to 85 keV were generated. Using these mono-energetic X-rays, the dosimeter was irradiated. Simultaneously, the fluence of the X-rays was determined with a CdTe detector. The energy-dependent efficiency of the dosimeter was derived from the measured value of the dosimeter and the fluence. Moreover, the energy-dependent efficiency was calculated by Monte-Carlo simulation. The efficiency obtained in the experiment was in good agreement with that of the simulation. In conclusion, our proposed method, in which characteristic X-rays are used, is valuable for measurement of the energy dependence of a small OSL dosimeter in the diagnostic X-ray region.

  16. Compact X-ray sources: X-rays from self-reflection

    NASA Astrophysics Data System (ADS)

    Mangles, Stuart P. D.

    2012-05-01

    Laser-based particle acceleration offers a way to reduce the size of hard-X-ray sources. Scientists have now developed a simple scheme that produces a bright flash of hard X-rays by using a single laser pulse both to generate and to scatter an electron beam.

  17. VizieR Online Data Catalog: Intermediate-luminosity X-ray objects catalog (Colbert+, 2002)

    NASA Astrophysics Data System (ADS)

    Colbert, E. J. M.; Ptak, A. F.

    2002-11-01

    ROSAT, and now Chandra, X-ray images allow studies of extranuclear X-ray point sources in galaxies other than our own. X-ray observations of normal galaxies with ROSAT and Chandra have revealed that off-nuclear, compact, intermediate-luminosity (LX[2-10keV]>=1039erg/s) X-ray objects (IXOs, a.k.a. ULXs [ultraluminous X-ray sources]) are quite common. Here we present a catalog and finding charts for 87 IXOs in 54 galaxies, derived from all of the ROSAT HRI imaging data for galaxies with cz<=5000km/s from the Third Reference Catalog of Bright Galaxies. (2 data files).

  18. Understanding the X-ray spectrum of anomalous X-ray pulsars and soft gamma-ray repeaters

    NASA Astrophysics Data System (ADS)

    Guo, Yan-Jun; Dai, Shi; Li, Zhao-Sheng; Liu, Yuan; Tong, Hao; Xu, Ren-Xin

    2015-04-01

    Hard X-rays above 10 keV are detected from several anomalous X-ray pulsars (AXPs) and soft gamma-ray repeaters (SGRs), and different models have been proposed to explain the physical origin within the frame of either a magnetar model or a fallback disk system. Using data from Suzaku and INTEGRAL, we study the soft and hard X-ray spectra of four AXPs/SGRs: 1RXS J170849-400910, 1E 1547.0-5408, SGR 1806-20 and SGR 0501+4516. It is found that the spectra could be well reproduced by the bulk-motion Comptonization (BMC) process as was first suggested by Trümper et al., showing that the accretion scenario could be compatible with X-ray emission from AXPs/SGRs. Simulated results from the Hard X-ray Modulation Telescope using the BMC model show that the spectra would have discrepancies from the power-law, especially the cutoff at ˜200 keV. Thus future observations will allow researchers to distinguish different models of the hard X-ray emission and will help us understand the nature of AXPs/SGRs. Supported by the National Natural Science Foundation of China.

  19. Solar flare hard and soft x ray relationship determined from SMM HXRBS and BCS data

    NASA Technical Reports Server (NTRS)

    Toot, G. David

    1989-01-01

    The exact nature of the solar flare process is still somewhat a mystery. A key element to understanding flares if the relationship between the hard x rays emitted by the most energetic portions of the flare and the soft x rays from other areas and times. This relationship was studied by comparing hard x ray light curved from the Hard X-Ray Burst Spectrometer (HXRBS) with the soft x ray light curve and its derivation from the Bent Crystal Spectrometer (BCS) which is part of the X-Ray Polychrometer (XRP), these instruments being on the Solar Maximum Mission spacecraft (SMM). Data sample was taken from flares observed with the above instruments during 1980, the peak of the previous maximum of solar activity. Flares were chosen based on complete coverage of the event by several instruments. The HXRBS data covers the x ray spectrum from about 25 keV to about 440 keV in 15 spectral channels, while the BCS data used covers a region of the Spectrum around 3 angstroms including emission from the Ca XIX ion. Both sets of data were summed over their spectral ranges and plotted against time at a maximum time resolution of around 3 seconds. The most popular theory of flares holds that a beam of electrons produces the hard x rays by bremsstrahlung while the soft x rays are the thermal response to this energy deposition. The question is whether the rate of change of soft x ray emission might reflect the variability of the electron beam and hence the variability of the hard x rays. To address this, we took the time derivative of the soft x ray light curve and compared it to the hard flares, 12 of them showed very closed agreement between the soft x ray derivative and the hard x ray light curve. The other five did not show this behavior but were similar to each other in general soft x ray behavior. Efforts to determine basic differences between the two kinds of flares continue. In addition the behavior of soft x ray temperature of flares was examined.

  20. Solar flare hard and soft X ray relationship determined from SMM HXRBS and BCS data

    NASA Astrophysics Data System (ADS)

    Toot, G. David

    1989-09-01

    The exact nature of the solar flare process is still somewhat a mystery. A key element to understanding flares if the relationship between the hard x rays emitted by the most energetic portions of the flare and the soft x rays from other areas and times. This relationship was studied by comparing hard x ray light curved from the Hard X-Ray Burst Spectrometer (HXRBS) with the soft x ray light curve and its derivation from the Bent Crystal Spectrometer (BCS) which is part of the X-Ray Polychrometer (XRP), these instruments being on the Solar Maximum Mission spacecraft (SMM). Data sample was taken from flares observed with the above instruments during 1980, the peak of the previous maximum of solar activity. Flares were chosen based on complete coverage of the event by several instruments. The HXRBS data covers the x ray spectrum from about 25 keV to about 440 keV in 15 spectral channels, while the BCS data used covers a region of the Spectrum around 3 angstroms including emission from the Ca XIX ion. Both sets of data were summed over their spectral ranges and plotted against time at a maximum time resolution of around 3 seconds. The most popular theory of flares holds that a beam of electrons produces the hard x rays by bremsstrahlung while the soft x rays are the thermal response to this energy deposition. The question is whether the rate of change of soft x ray emission might reflect the variability of the electron beam and hence the variability of the hard x rays. To address this, we took the time derivative of the soft x ray light curve and compared it to the hard flares, 12 of them showed very closed agreement between the soft x ray derivative and the hard x ray light curve. The other five did not show this behavior but were similar to each other in general soft x ray behavior. Efforts to determine basic differences between the two kinds of flares continue. In addition the behavior of soft x ray temperature of flares was examined.

  1. X-ray crystallography

    NASA Technical Reports Server (NTRS)

    2001-01-01

    X-rays diffracted from a well-ordered protein crystal create sharp patterns of scattered light on film. A computer can use these patterns to generate a model of a protein molecule. To analyze the selected crystal, an X-ray crystallographer shines X-rays through the crystal. Unlike a single dental X-ray, which produces a shadow image of a tooth, these X-rays have to be taken many times from different angles to produce a pattern from the scattered light, a map of the intensity of the X-rays after they diffract through the crystal. The X-rays bounce off the electron clouds that form the outer structure of each atom. A flawed crystal will yield a blurry pattern; a well-ordered protein crystal yields a series of sharp diffraction patterns. From these patterns, researchers build an electron density map. With powerful computers and a lot of calculations, scientists can use the electron density patterns to determine the structure of the protein and make a computer-generated model of the structure. The models let researchers improve their understanding of how the protein functions. They also allow scientists to look for receptor sites and active areas that control a protein's function and role in the progress of diseases. From there, pharmaceutical researchers can design molecules that fit the active site, much like a key and lock, so that the protein is locked without affecting the rest of the body. This is called structure-based drug design.

  2. A Synthesis Of Cosmic X-ray And Infrared Background

    NASA Astrophysics Data System (ADS)

    Shi, Yong; Helou, G.; Armus, L.; Stierwalt, S.

    2012-01-01

    We present a synthesis model of cosmic IR and X-ray background, with the goal to derive a complete census of cosmic evolution of star formation (SF) and black-hole (BH) growth by complementing advantages of X-ray and IR surveys to each other. By assuming that individual galaxies are experiencing both SF and BH accretion, our model decomposes the total IR LF into SF and BH components while taking into account the luminosity-dependent SED and its dispersion of the SF component, and the extinction-dependent SED of the BH component. The best-fit parameters are derived by fitting to the number counts and redshift distributions at X-ray including both hard and soft bands, and mid-IR to submm bands including IRAS, Spitzer, Herschel, SCUBA, Aztec and MAMBO. Based on the fit result, our models provide a series of predictions on galaxy evolution and black-hole growth. For evolution of infrared galaxies, the model predicts that the total infrared luminosity function is best described through evolution in both luminosity and density. For evolution of AGN populations, the model predicts that the evolution of X-ray LF also shows luminosity and density dependent, that the type-1/type-2 AGN fraction is a function of both luminosity and redshift, and that the Compton-thick AGN number density evolves strongly with redshift, contributing about 20% to the total cosmic BH growth. For BH growth in IR galaxies, the model predicts that the majority of BH growth at z>1 occurs in infrared luminous galaxies and the AGN fraction as a function of IR survey is a strong function of the survey depth, ranging from >50% at bright end to below 10% at faint end. We also evaluates various AGN selection techniques at X-ray and IR wavelengths and offer predictions for future missions at X-ray and IR.

  3. X-Ray Shadowing Experiments Toward Infrared Dark Clouds

    NASA Technical Reports Server (NTRS)

    Anderson, L. E.; Snowden, S.; Bania, T. M.

    2009-01-01

    We searched for X-ray shadowing toward two infrared dark clouds (IRDCs) using the MOS detectors on XMM-Newton to learn about the Galactic distribution of X-ray emitting plasma. IRDCs make ideal X-ray shadowing targets of 3/4 keY photons due to their high column densities, relatively large angular sizes, and known kinematic distances. Here we focus on two clouds near 30 deg Galactic longitude at distances of 2 and 5 kpc from the Sun. We derive the foreground and background column densities of molecular and atomic gas in the direction of the clouds. We find that the 3/4 ke V emission must be distributed throughout the Galactic disk. It is therefore linked to the structure of the cooler material of the ISM, and to the birth of stars.

  4. The Advanced X-Ray Astrophysics Facility. Observing the Universe in X-Rays

    NASA Technical Reports Server (NTRS)

    Neal, V.

    1984-01-01

    An overview of the Advanced X ray Astronophysics Facility (AXAF) program is presented. Beginning with a brief introduction to X ray astrophysics, the AXAF observatory is described including the onboard instrumentation and system capabilities. Possible X ray sources suitable for AXAF observation are identified and defined.

  5. X-ray generation using carbon nanotubes

    NASA Astrophysics Data System (ADS)

    Parmee, Richard J.; Collins, Clare M.; Milne, William I.; Cole, Matthew T.

    2015-01-01

    Since the discovery of X-rays over a century ago the techniques applied to the engineering of X-ray sources have remained relatively unchanged. From the inception of thermionic electron sources, which, due to simplicity of fabrication, remain central to almost all X-ray applications, there have been few fundamental technological advances. However, with the emergence of ever more demanding medical and inspection techniques, including computed tomography and tomosynthesis, security inspection, high throughput manufacturing and radiotherapy, has resulted in a considerable level of interest in the development of new fabrication methods. The use of conventional thermionic sources is limited by their slow temporal response and large physical size. In response, field electron emission has emerged as a promising alternative means of deriving a highly controllable electron beam of a well-defined distribution. When coupled to the burgeoning field of nanomaterials, and in particular, carbon nanotubes, such systems present a unique technological opportunity. This review provides a summary of the current state-of-the-art in carbon nanotube-based field emission X-ray sources. We detail the various fabrication techniques and functional advantages associated with their use, including the ability to produce ever smaller electron beam assembles, shaped cathodes, enhanced temporal stability and emergent fast-switching pulsed sources. We conclude with an overview of some of the commercial progress made towards the realisation of an innovative and disruptive technology.

  6. The Mapping X-ray Fluorescence Spectrometer (MapX)

    NASA Astrophysics Data System (ADS)

    Sarrazin, P.; Blake, D. F.; Marchis, F.; Bristow, T.; Thompson, K.

    2017-12-01

    Many planetary surface processes leave traces of their actions as features in the size range 10s to 100s of microns. The Mapping X-ray Fluorescence Spectrometer (MapX) will provide elemental imaging at 100 micron spatial resolution, yielding elemental chemistry at a scale where many relict physical, chemical, or biological features can be imaged and interpreted in ancient rocks on planetary bodies and planetesimals. MapX is an arm-based instrument positioned on a rock or regolith with touch sensors. During an analysis, an X-ray source (tube or radioisotope) bombards the sample with X-rays or alpha-particles / gamma-rays, resulting in sample X-ray Fluorescence (XRF). X-rays emitted in the direction of an X-ray sensitive CCD imager pass through a 1:1 focusing lens (X-ray micro-pore Optic (MPO)) that projects a spatially resolved image of the X-rays onto the CCD. The CCD is operated in single photon counting mode so that the energies and positions of individual X-ray photons are recorded. In a single analysis, several thousand frames are both stored and processed in real-time. Higher level data products include single-element maps with a lateral spatial resolution of 100 microns and quantitative XRF spectra from ground- or instrument- selected Regions of Interest (ROI). XRF spectra from ROI are compared with known rock and mineral compositions to extrapolate the data to rock types and putative mineralogies. When applied to airless bodies and implemented with an appropriate radioisotope source for alpha-particle excitation, MapX will be able to analyze biogenic elements C, N, O, P, S, in addition to the cations of the rock-forming elements >Na, accessible with either X-ray or gamma-ray excitation. The MapX concept has been demonstrated with a series of lab-based prototypes and is currently under refinement and TRL maturation.

  7. A cross-sectional study on sarcopenia using different methods: reference values for healthy Saudi young men.

    PubMed

    Alkahtani, Shaea A

    2017-03-21

    The aim of this study was to determine reference values for sarcopenia indices using different methods in healthy Saudi young men. Participants included 232 Saudi men aged between 20 and 35 years. The study measured anthropometric indices, blood pressure, hand grip strength, and lean muscle mass using dual-energy X-ray absorptiometry (DXA), and bioelectrical impedance analysis (BIA) was performed using Inbody 770 and Tanita 980 devices. Using DXA, the mean value of appendicular lean mass divided by the height squared (ALM/ht 2 ) was found to be 8.97 ± 1.23 kg/m 2 ; hand grip strength measured 42.8 ± 7.6 kg. While the differences between DXA and BIA (Tanita) were significant for all parameters, the differences between DXA and Inbody values were significant only for ALM parameters. Inbody sensitivity and specificity values were 73% and 95.9%, respectively. The kappa (P = 0.80) and p values (P < 0.001) showed good agreement between Inbody and DXA, whereas Tanita sensitivity and specificity values were 54.2% and 98.3%, respectively. Bland-Altman plots for differences in lean mass values between Tanita, Inbody, and DXA methods showed very high bias for Tanita and DXA, with significant differences (P < 0.001). The cut-off values for sarcopenia indices for Saudi young men are different from those of other ethnicities. The use of tailored cut-off reference values instead of a general cut-off for BIA devices is recommended.

  8. Comparison of body composition methods during weight loss in obese women using herbal formula.

    PubMed

    Kim, Ho-Jun; Gallagher, Dympna; Song, Mi-Yeon

    2005-01-01

    Bioelectrical impedance analysis (BIA), a device that analyzes the current conduction differences between the fat and water components is widely used for reasons that include convenience of use, non-invasiveness, safety, and low cost. Dual energy X-ray absorptiometry (DXA) allows for the assessment of total body and regional lean and fat tissues and bone mineral content (BMC). The objective of this study was to compare body composition assessments by BIA and DXA before and after a 6-week herbal diet intervention program in 50 pre-menopausal women [mean +/- SD: age 30.58 +/- 6.15, body mass index (BMI) 31.72 +/- 3.78]. Waist-to-hip ratio (WHR) was measured by BIA and anthropometry. Lean body mass (LBM), body fat (BF), BMC and percent body fat (%BF) were measured by BIA and DXA. Highly significant correlations were observed between BIA and DXA measurements for LBM, BF, BMC and %BF (r = 0.73, 0.93, 0.53, 0.79, respectively) before the intervention. Differences between BIA and DXA measurements were observed in LBM, BF, %BF and BMC before intervention (p < 0.01) where WHR by BIA was significantly higher compared to anthropometry before (p < 0.01) and after the intervention (p < 0.01). BIA underestimated LBM by 1.85 kg and overestimated BF by 2.54 kg compared to DXA before the intervention. Although BIA and DXA showed highly significant correlations for LBM, BF, BMC and %BF before the intervention, they did not produce statistically comparable results in pre-menopausal Korean women and therefore should not be used interchangeably when measuring body composition.

  9. Cosmic x ray physics

    NASA Technical Reports Server (NTRS)

    Mccammon, Dan; Cox, D. P.; Kraushaar, W. L.; Sanders, W. T.

    1990-01-01

    The annual progress report on Cosmic X Ray Physics is presented. Topics studied include: the soft x ray background, proportional counter and filter calibrations, the new sounding rocket payload: X Ray Calorimeter, and theoretical studies.

  10. Comparison of Indian Council for Medical Research and Lunar Databases for Categorization of Male Bone Mineral Density.

    PubMed

    Singh, Surya K; Patel, Vivek H; Gupta, Balram

    2017-06-19

    The mainstay of diagnosis of osteoporosis is dual-energy X-ray absorptiometry (DXA) scan measuring areal bone mineral density (BMD) (g/cm 2 ). The aim of the present study was to compare the Indian Council of Medical Research database (ICMRD) and the Lunar ethnic reference database of DXA scans in the diagnosis of osteoporosis in male patients. In this retrospective study, all male patients who underwent a DXA scan were included. The areal BMD (g/cm 2 ) was measured at either the lumbar spine (L1-L4) or the total hip using the Lunar DXA machine (software version 8.50) manufactured by GE Medical Systems (Shanghai, China). The Indian Council of Medical Research published a reference data for BMD in the Indian population derived from the population-based study conducted in healthy Indian individuals, which was used to analyze the BMD result by Lunar DXA scan. The 2 results were compared for various values using statistical software SPSS for Windows (version 16; SPSS Inc., Chicago, IL). A total 238 male patients with a mean age of 57.2 yr (standard deviation ±15.9) were included. Overall, 26.4% (66/250) and 2.8% (7/250) of the subjects were classified in the osteoporosis group according to the Lunar database and the ICMRD, respectively. Out of the 250 sites of the DXA scan, 28.8% (19/66) and 60.0% (40/66) of the cases classified as osteoporosis by the Lunar database were reclassified as normal and osteopenia by ICMRD, respectively. In conclusion, the Indian Council of Medical Research data underestimated the degree of osteoporosis in male subjects that might result in deferring of treatment. In view of the discrepancy, the decision on the treatment of osteoporosis should be based on the multiple fracture risk factors and less reliably on the BMD T-score. Copyright © 2017 The International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.

  11. Anthropometry-based Equations to Estimate Body Composition: A Suitable Alternative in Renal Transplant Recipients and Patients With Nondialysis Dependent Kidney Disease?

    PubMed

    Wilkinson, Thomas J; Richler-Potts, Danielle; Nixon, Daniel G D; Neale, Jill; Smith, Alice C

    2018-05-24

    Chronic kidney disease (CKD) patients and renal transplant recipients (RTRs) are characterized by aberrant body composition such as muscle wasting and obesity. It is still unknown which is the most accurate method to estimate body composition in CKD. We investigated the validity of the Hume equation and bioelectrical impedance analysis (BIA) as an estimate of body composition against dual-energy X-ray absorptiometry (DXA) in a cohort of nondialysis dependent (NDD)-CKD and RTRs. This was a cross-sectional study with agreement analysis of different assessments of body composition conducted in 61 patients (35 RTRs and 26 NDD-CKD) in a secondary care hospital setting in the UK. Body composition (lean mass [LM], fat mass [FM], and body fat% [BF%]) was assessed using multifrequency BIA and DXA, and estimated using the Hume formula. Method agreement was assessed by intraclass correlation coefficient (ICC), regression, and plotted by Bland and Altman analysis. Both BIA and the Hume formula were able to accurately estimate body composition against DXA. In both groups, the BIA overestimated LM (1.7-2.1 kg, ICC .980-.984) and underestimated FM (1.3-2.1 kg, ICC .967-.972) and BF% (3.1-3.8%, ICC .927-.954). The Hume formula also overestimated LM (3.5-3.6 kg, ICC .950-.960) and underestimated BF% (1.9-2.1%, ICC .808-.859). Hume-derived FM was almost identical to DXA in both groups (-0.3 to 0.1 kg, ICC .947-.960). Our results demonstrate, in RTR and NDD-CKD patients, that the Hume formula, whose estimation of body composition is based only upon height, body mass, age, and sex, may reliably predict the same parameters obtained by DXA. In addition, BIA also provided similar estimates versus DXA. Thus, the Hume formula and BIA could provide simple and inexpensive means to estimate body composition in renal disease. Copyright © 2018 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.

  12. Focusing X-Ray Telescopes

    NASA Technical Reports Server (NTRS)

    O'Dell, Stephen; Brissenden, Roger; Davis, William; Elsner, Ronald; Elvis, Martin; Freeman, Mark; Gaetz, Terrance; Gorenstein, Paul; Gubarev, Mikhall; Jerlus, Diab; hide

    2010-01-01

    During the half-century history of x-ray astronomy, focusing x-ray telescopes, through increased effective area and finer angular resolution, have improved sensitivity by 8 orders of magnitude. Here, we review previous and current x-ray-telescope missions. Next, we describe the planned next-generation x-ray-astronomy facility, the International X-ray Observatory (IXO). We conclude with an overview of a concept for the next next-generation facility, Generation X. Its scientific objectives will require very large areas (about 10,000 sq m) of highly-nested, lightweight grazing-incidence mirrors, with exceptional (about 0.1-arcsec) resolution. Achieving this angular resolution with lightweight mirrors will likely require on-orbit adjustment of alignment and figure.

  13. Luminosity function and cosmological evolution of X-ray selected quasars

    NASA Technical Reports Server (NTRS)

    Maccacaro, T.; Gioia, I. M.

    1983-01-01

    The preliminary analysis of a complete sample of 55 X-ray sources is presented as part of the Medium Sensitivity Survey of the Einstein Observatory. A pure luminosity evolutionary law is derived in order to determine the uniform distribution of the sources and the rates of evolution for Active Galactic Nuclei (AGNs) observed by X-ray and optical techniques are compared. A nonparametric representation of the luminosity function is fitted to the observational data. On the basis of the reduced data, it is determined that: (1) AGNs evolve cosmologically; (2) less evolution is required to explain the X-ray data than the optical data; (3) the high-luminosity portion of the X-ray luminosity can be described by a power-law with a slope of gamma = 3.6; and (4) the X-ray luminosity function flattens at low luminosities. Some of the implications of the results for conventional theoretical models of the evolution of quasars and Seyfert galaxies are discussed.

  14. Cosmic x ray physics

    NASA Technical Reports Server (NTRS)

    Mccammon, Dan; Cox, D. P.; Kraushaar, W. L.; Sanders, W. T.

    1991-01-01

    The annual progress report on Cosmic X Ray Physics for the period 1 Jan. to 31 Dec. 1990 is presented. Topics studied include: soft x ray background, new sounding rocket payload: x ray calorimeter, and theoretical studies.

  15. Stellar wind measurements for Colliding Wind Binaries using X-ray observations

    NASA Astrophysics Data System (ADS)

    Sugawara, Yasuharu; Maeda, Yoshitomo; Tsuboi, Yohko

    2017-11-01

    We report the results of the stellar wind measurement for two colliding wind binaries. The X-ray spectrum is the best measurement tool for the hot postshock gas. By monitoring the changing of the the X-ray luminosity and column density along with the orbital phases, we derive the mass-loss rates of these stars.

  16. Multi-Layer Organic Squaraine-Based Photodiode for Indirect X-Ray Detection

    NASA Astrophysics Data System (ADS)

    Iacchetti, Antonio; Binda, Maddalena; Natali, Dario; Giussani, Mattia; Beverina, Luca; Fiorini, Carlo; Peloso, Roberta; Sampietro, Marco

    2012-10-01

    The paper presents an organic-based photodiode coupled to a CsI(Tl) scintillator to realize an X-ray detector. A suitable blend of an indolic squaraine derivative and of fullerene derivative has been used for the photodiode, thus allowing external quantum efficiency in excess of 10% at a wavelength of 570 nm, well matching the scintillator output spectrum. Thanks to the additional deposition of a 15 nm thin layer of a suitable low electron affinity polymer, carriers injection from the metal into the organic semiconductor has been suppressed, and dark current density as low as has been obtained, which is comparable to standard Si-based photodiodes. By using a collimated X-ray beam impinging onto the scintillator mounted over the photodiode we have been able to measure current variations in the order of 150 pA on a dark current floor of less than 50 pA when operating the X-ray tube in switching mode, thus proving the feasibility of indirect X-ray detection by means of organic semiconductors.

  17. X-ray lasers

    NASA Astrophysics Data System (ADS)

    Elton, Raymond C.

    Theoretical and practical aspects of X-ray lasers are discussed in an introduction emphasizing recent advances. Chapters are devoted to the unique optical properties of the X-ray spectral region, the principles of short-wavelength lasers, pumping by exciting plasma ions, pumping by electron capture into excited ionic states, pumping by ionization of atoms and ions, and alternative approaches. The potential scientific, technical, biological, and medical applications of X-ray lasers are briefly characterized.

  18. The superslow pulsation X-ray pulsars in high mass X-ray binaries

    NASA Astrophysics Data System (ADS)

    Wang, Wei

    2013-03-01

    There exists a special class of X-ray pulsars that exhibit very slow pulsation of P spin > 1000 s in the high mass X-ray binaries (HMXBs). We have studied the temporal and spectral properties of these superslow pulsation neutron star binaries in hard X-ray bands with INTEGRAL observations. Long-term monitoring observations find spin period evolution of two sources: spin-down trend for 4U 2206+54 (P spin ~ 5560 s with Ṗ spin ~ 4.9 × 10-7 s s-1) and long-term spin-up trend for 2S 0114+65 (P spin ~ 9600 s with Ṗ spin ~ -1 × 10-6 s s-1) in the last 20 years. A Be X-ray transient, SXP 1062 (P spin ~ 1062 s), also showed a fast spin-down rate of Ṗ spin ~ 3 × 10-6 s s-1 during an outburst. These superslow pulsation neutron stars cannot be produced in the standard X-ray binary evolution model unless the neutron star has a much stronger surface magnetic field (B > 1014 G). The physical origin of the superslow spin period is still unclear. The possible origin and evolution channels of the superslow pulsation X-ray pulsars are discussed. Superslow pulsation X-ray pulsars could be younger X-ray binary systems, still in the fast evolution phase preceding the final equilibrium state. Alternatively, they could be a new class of neutron star system - accreting magnetars.

  19. Miniature x-ray source

    DOEpatents

    Trebes, James E.; Stone, Gary F.; Bell, Perry M.; Robinson, Ronald B.; Chornenky, Victor I.

    2002-01-01

    A miniature x-ray source capable of producing broad spectrum x-ray emission over a wide range of x-ray energies. The miniature x-ray source comprises a compact vacuum tube assembly containing a cathode, an anode, a high voltage feedthru for delivering high voltage to the anode, a getter for maintaining high vacuum, a connection for an initial vacuum pump down and crimp-off, and a high voltage connection for attaching a compact high voltage cable to the high voltage feedthru. At least a portion of the vacuum tube wall is highly x-ray transparent and made, for example, from boron nitride. The compact size and potential for remote operation allows the x-ray source, for example, to be placed adjacent to a material sample undergoing analysis or in proximity to the region to be treated for medical applications.

  20. Wide-area phase-contrast X-ray imaging using large X-ray interferometers

    NASA Astrophysics Data System (ADS)

    Momose, Atsushi; Takeda, Tohoru; Yoneyama, Akio; Koyama, Ichiro; Itai, Yuji

    2001-07-01

    Large X-ray interferometers are developed for phase-contrast X-ray imaging aiming at medical applications. A monolithic X-ray interferometer and a separate one are studied, and currently a 25 mm×20 mm view area can be generated. This paper describes the strategy of our research program and some recent developments.

  1. The Focusing Optics Solar X-ray Imager (FOXSI)

    NASA Astrophysics Data System (ADS)

    Christe, Steven; Glesener, L.; Krucker, S.; Ramsey, B.; Ishikawa, S.; Takahashi, T.; Tajima, H.

    2010-05-01

    The Focusing Optics x-ray Solar Imager (FOXSI) is a sounding rocket payload funded under the NASA Low Cost Access to Space program to test hard x-ray focusing optics and position-sensitive solid state detectors for solar observations. Today's leading solar hard x-ray instrument, the Reuven Ramaty High Energy Solar Spectroscopic Imager (RHESSI) provides excellent spatial (2 arcseconds) and spectral (1 keV) resolution. Yet, due to its use of indirect imaging, the derived images have a low dynamic range (<30) and sensitivity. These limitations make it difficult to study faint x-ray sources in the solar corona which are crucial for understanding the solar flare acceleration process. Grazing-incidence x-ray focusing optics combined with position-sensitive solid state detectors can overcome both of these limitations enabling the next breakthrough in understanding particle acceleration in solar flares. The FOXSI project is led by the Space Science Laboratory at the University of California. The NASA Marshall Space Flight Center, with experience from the HERO balloon project, is responsible for the grazing-incidence optics, while the Astro H team (JAXA/ISAS) will provide double-sided silicon strip detectors. FOXSI will be a pathfinder for the next generation of solar hard x-ray spectroscopic imagers. Such observatories will be able to image the non-thermal electrons within the solar flare acceleration region, trace their paths through the corona, and provide essential quantitative measurements such as energy spectra, density, and energy content in accelerated electrons.

  2. The Focusing Optics X-ray Solar Imager (FOXSI)

    NASA Astrophysics Data System (ADS)

    Krucker, Sam; Christe, Steven; Glesener, Lindsay; McBride, Steve; Turin, Paul; Glaser, David; Saint-Hilaire, Pascal; Delory, Gregory; Lin, R. P.; Gubarev, Mikhail; Ramsey, Brian; Terada, Yukikatsu; Ishikawa, Shin-Nosuke; Kokubun, Motohide; Saito, Shinya; Takahashi, Tadayuki; Watanabe, Shin; Nakazawa, Kazuhiro; Tajima, Hiroyasu; Masuda, Satoshi; Minoshima, Takashi; Shomojo, Masumi

    2009-08-01

    The Focusing Optics x-ray Solar Imager (FOXSI) is a sounding rocket payload funded under the NASA Low Cost Access to Space program to test hard x-ray focusing optics and position-sensitive solid state detectors for solar observations. Today's leading solar hard x-ray instrument, the Reuven Ramaty High Energy Solar Spectroscopic Imager (RHESSI) provides excellent spatial (2 arcseconds) and spectral (1 keV) resolution. Yet, due to its use of indirect imaging, the derived images have a low dynamic range (<30) and sensitivity. These limitations make it difficult to study faint x-ray sources in the solar corona which are crucial for understanding the solar flare acceleration process. Grazing-incidence x-ray focusing optics combined with position-sensitive solid state detectors can overcome both of these limitations enabling the next breakthrough in understanding particle acceleration in solar flares. The FOXSI project is led by the Space Science Laboratory at the University of California. The NASA Marshall Space Flight Center, with experience from the HERO balloon project, is responsible for the grazing-incidence optics, while the Astro H team (JAXA/ISAS) will provide double-sided silicon strip detectors. FOXSI will be a pathfinder for the next generation of solar hard x-ray spectroscopic imagers. Such observatories will be able to image the non-thermal electrons within the solar flare acceleration region, trace their paths through the corona, and provide essential quantitative measurements such as energy spectra, density, and energy content in accelerated electrons.

  3. The Focusing Optics Solar X-ray Imager (FOXSI)

    NASA Astrophysics Data System (ADS)

    Christe, S.; Glesener, L.; Krucker, S.; Ramsey, B.; Ishikawa, S.; Takahashi, T.

    2009-12-01

    The Focusing Optics x-ray Solar Imager is a sounding rocket payload funded under the NASA Low Cost Access to Space program to test hard x-ray focusing optics and position-sensitive solid state detectors for solar observations. Today's leading solar hard x-ray instrument, the Reuven Ramaty High Energy Solar Spectroscopic Imager provides excellent spatial (2 arcseconds) and spectral (1~keV) resolution. Yet, due to its use of indirect imaging, the derived images have a low dynamic range (<30) and sensitivity. These limitations make it difficult to study faint x-ray sources in the solar corona which are crucial for understanding the solar flare acceleration process. Grazing-incidence x-ray focusing optics combined with position-sensitive solid state detectors can overcome both of these limitations enabling the next breakthrough in understanding particle acceleration in solar flares. The foxsi project is led by the Space Science Laboratory at the University of California. The NASA Marshall Space Flight Center, with experience from the HERO balloon project, is responsible for the grazing-incidence optics, while the Astro H team (JAXA/ISAS) will provide double-sided silicon strip detectors. FOXSI will be a pathfinder for the next generation of solar hard x-ray spectroscopic imagers. Such observatories will be able to image the non-thermal electrons within the solar flare acceleration region, trace their paths through the corona, and provide essential quantitative measurements such as energy spectra, density, and energy content in accelerated electrons.

  4. Combining MeV-GeV γ-ray and X-ray Observations: A Broadband View of Supernova Remnant Kes 41

    NASA Astrophysics Data System (ADS)

    Castro, Daniel; Joubert, Timothy; Slane, Patrick O.; Figueroa-Feliciano, Enectali

    2015-01-01

    We report the detection of γ-ray emission coincident with the supernova remnant (SNR) Kes 41, using data from the Large Area Telescope on board the Fermi Gamma-ray Space Telescope. Kes 41 is believed to be interacting with molecular clouds, as evidenced by observations of hydroxyl (OH) maser emission at 1720 MHz in its direction and other observational information. SNR shocks are expected to be sites of cosmic ray acceleration, and clouds of dense material can provide effective targets for production of γ-rays from π0-decay. We model its broadband nonthermal emission (from radio to γ-ray) using a simple one-zone model, and after considering scenarios where the MeV-GeV source originate in either π0-decay or leptonic emission, we conclude that the γ-rays must be produced through the hadronic channel and derive a lower limit to the density with which the SNR is interacting. Additionally, we analyze the XMM-Newton X-ray observation of this remnant and derive an approximate density of the emmitting material. The discrepancy between the densities derived from the X-ray and γ-ray is discussed.

  5. Monoalkylated barbiturate derivatives: X-ray crystal structure, theoretical studies, and biological activities

    NASA Astrophysics Data System (ADS)

    Barakat, Assem; Al-Majid, Abdullah Mohammed; Soliman, Saied M.; Islam, Mohammad Shahidul; Ghawas, Hussain Mansur; Yousuf, Sammer; Choudhary, M. Iqbal; Wadood, Abdul

    2017-08-01

    Barbiturate derivatives are privileged structures with a broad range of pharmaceutical applications. We prepared a series of 5-monoalkylated barbiturate derivatives (3a-l) and evaluated, in vitro, their antioxidant (DPPH assay), and α-glucosidase inhibitory activities. Compounds 3a-l were synthesized via Michael addition. The structure of compound 3k was determined using X-ray single-crystal diffraction, and geometric parameters were calculated using density functional theory at the B3LYP/6-311G(d,p) level of theory. Further, the structural analysis of 3k were also investigated. Biological studies revealed that compounds 3b (IC50 = 133.1 ± 3.2 μM), 3d (IC50 = 305 ± 7.7 μM), and 3e (IC50 = 184 ± 2.3 μM) have potent α-glucosidase enzyme inhibitors and showed greater activity than the standard drug acarbose (IC50 = 841 ± 1.73 μM). Compounds 3a-3i were found to show weak antioxidant activity against 1,1-diphenyl-2-picryl-hydrazyl (DPPH) radicals (IC50 = 91 ± 0.75 to 122 ± 1.0 μM) when tested against a standard antioxidant, gallic acid (IC50 = 23 ± 0.43 μM).

  6. Bone volume fraction and structural parameters for estimation of mechanical stiffness and failure load of human cancellous bone samples; in-vitro comparison of ultrasound transit time spectroscopy and X-ray μCT.

    PubMed

    Alomari, Ali Hamed; Wille, Marie-Luise; Langton, Christian M

    2018-02-01

    Conventional mechanical testing is the 'gold standard' for assessing the stiffness (N mm -1 ) and strength (MPa) of bone, although it is not applicable in-vivo since it is inherently invasive and destructive. The mechanical integrity of a bone is determined by its quantity and quality; being related primarily to bone density and structure respectively. Several non-destructive, non-invasive, in-vivo techniques have been developed and clinically implemented to estimate bone density, both areal (dual-energy X-ray absorptiometry (DXA)) and volumetric (quantitative computed tomography (QCT)). Quantitative ultrasound (QUS) parameters of velocity and attenuation are dependent upon both bone quantity and bone quality, although it has not been possible to date to transpose one particular QUS parameter into separate estimates of quantity and quality. It has recently been shown that ultrasound transit time spectroscopy (UTTS) may provide an accurate estimate of bone density and hence quantity. We hypothesised that UTTS also has the potential to provide an estimate of bone structure and hence quality. In this in-vitro study, 16 human femoral bone samples were tested utilising three techniques; UTTS, micro computed tomography (μCT), and mechanical testing. UTTS was utilised to estimate bone volume fraction (BV/TV) and two novel structural parameters, inter-quartile range of the derived transit time (UTTS-IQR) and the transit time of maximum proportion of sonic-rays (TTMP). μCT was utilised to derive BV/TV along with several bone structure parameters. A destructive mechanical test was utilised to measure the stiffness and strength (failure load) of the bone samples. BV/TV was calculated from the derived transit time spectrum (TTS); the correlation coefficient (R 2 ) with μCT-BV/TV was 0.885. For predicting mechanical stiffness and strength, BV/TV derived by both μCT and UTTS provided the strongest correlation with mechanical stiffness (R 2 =0.567 and 0.618 respectively) and

  7. Can mandibular bone resorption predict hip fracture in elderly women? A systematic review of diagnostic test accuracy.

    PubMed

    Devlin, Hugh; Whelton, Christopher

    2015-09-01

    The aim of this systematic review was to determine the diagnostic accuracy of the mandibular cortical width measurements and porosity in detecting hip osteoporosis. All of the included studies used measurements on panoramic radiographs. Studies were included if they compared the radiographic measurements (or index tests) with central dual energy X-ray absorptiometry (DXA) of the hip as the reference standard. A measure of diagnostic accuracy such as sensitivity and specificity or area under the receiver operating characteristic curve was also required for inclusion. Seven studies were identified. Meta-analysis was not possible because of the heterogeneity of the studies. The studies all demonstrated moderate diagnostic accuracy. If a patient with a thin or porous mandibular cortex is identified by a chance radiographic finding, additional clinical risk factors need to be considered and the patient referred for further investigation with DXA where necessary. © 2013 John Wiley & Sons A/S and The Gerodontology Society. Published by John Wiley & Sons Ltd.

  8. X-Pinch And Its Applications In X-ray Radiograph

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zou Xiaobing; Wang Xinxin; Liu Rui

    2009-07-07

    An X-pinch device and the related diagnostics of x-ray emission from X-pinch were briefly described. The time-resolved x-ray measurements with photoconducting diodes show that the x-ray pulse usually consists of two subnanosecond peaks with a time interval of about 0.5 ns. Being consistent with these two peaks of the x-ray pulse, two point x-ray sources of size ranging from 100 mum to 5 mum and depending on cut-off x-ray photon energy were usually observed on the pinhole pictures. The x-pinch was used as x-ray source for backlighting of the electrical explosion of single wire and the evolution of X-pinch, andmore » for phase-contrast imaging of soft biological objects such as a small shrimp and a mosquito.« less

  9. Evolution of X-ray astronomy

    NASA Technical Reports Server (NTRS)

    Rossj, B.

    1981-01-01

    The evolution of X-ray astronomy up to the launching of the Einstein observatory is presented. The evaluation proceeded through the following major steps: (1) discovery of an extrasolar X-ray source, Sco X-1, orders of magnitude stronger than astronomers believed might exist; (2) identification of a strong X-ray source with the Crab Nebula; (3) identification of Sco X-1 with a faint, peculiar optical object; (4) demonstration that X-ray stars are binary systems, each consisting of a collapsed object accreting matter from an ordinary star; (5) discovery of X-ray bursts; (6) discovery of exceedingly strong X-ray emission from active galaxies, quasars and clusters of galaxies; (7) demonstration that the principal X-ray source is a hot gas filling the space between galaxies.

  10. Active x-ray optics for Generation-X, the next high resolution x-ray observatory

    NASA Astrophysics Data System (ADS)

    Elvis, Martin; Brissenden, R. J.; Fabbiano, G.; Schwartz, D. A.; Reid, P.; Podgorski, W.; Eisenhower, M.; Juda, M.; Phillips, J.; Cohen, L.; Wolk, S.

    2006-06-01

    X-rays provide one of the few bands through which we can study the epoch of reionization, when the first galaxies, black holes and stars were born. To reach the sensitivity required to image these first discrete objects in the universe needs a major advance in X-ray optics. Generation-X (Gen-X) is currently the only X-ray astronomy mission concept that addresses this goal. Gen-X aims to improve substantially on the Chandra angular resolution and to do so with substantially larger effective area. These two goals can only be met if a mirror technology can be developed that yields high angular resolution at much lower mass/unit area than the Chandra optics, matching that of Constellation-X (Con-X). We describe an approach to this goal based on active X-ray optics that correct the mid-frequency departures from an ideal Wolter optic on-orbit. We concentrate on the problems of sensing figure errors, calculating the corrections required, and applying those corrections. The time needed to make this in-flight calibration is reasonable. A laboratory version of these optics has already been developed by others and is successfully operating at synchrotron light sources. With only a moderate investment in these optics the goals of Gen-X resolution can be realized.

  11. Development of X-ray CCD camera based X-ray micro-CT system

    NASA Astrophysics Data System (ADS)

    Sarkar, Partha S.; Ray, N. K.; Pal, Manoj K.; Baribaddala, Ravi; Agrawal, Ashish; Kashyap, Y.; Sinha, A.; Gadkari, S. C.

    2017-02-01

    Availability of microfocus X-ray sources and high resolution X-ray area detectors has made it possible for high resolution microtomography studies to be performed outside the purview of synchrotron. In this paper, we present the work towards the use of an external shutter on a high resolution microtomography system using X-ray CCD camera as a detector. During micro computed tomography experiments, the X-ray source is continuously ON and owing to the readout mechanism of the CCD detector electronics, the detector registers photons reaching it during the read-out period too. This introduces a shadow like pattern in the image known as smear whose direction is defined by the vertical shift register. To resolve this issue, the developed system has been incorporated with a synchronized shutter just in front of the X-ray source. This is positioned in the X-ray beam path during the image readout period and out of the beam path during the image acquisition period. This technique has resulted in improved data quality and hence the same is reflected in the reconstructed images.

  12. X-ray observations of the supernova remnant MSH 11-54

    NASA Technical Reports Server (NTRS)

    Agrawal, P. C.; Riegler, G. R.

    1980-01-01

    Soft X-ray observations of the X-ray source H1122-59 in the 0.4-2 keV band made with the low-energy detector 1 of the HEAO A-2 experiment are described. Based on positional coincidence, the source is identified with the supernova remnant MSH-11-54, thus confirming the report of Share et al. (1980). The object is a bright source in the 0.4-2 keV band with an X-ray flux of 9 x 10 to the -11th ergs/sq cm s near the earth. The measured source spectrum implies a plasma temperature of 4 million K and X-ray luminosity in the 0.4-2 keV band of 10 to the 37th ergs/s using a distance of 10 kpc for MSH 11-54. The X-ray observations, interpreted in terms of an adiabatic shock wave model, give a shock velocity of about 560 km/s and a supernova age of about 2300 yr, in good agreement with the age derived from the radio observations.

  13. Chandra X-ray Observatory - NASA's flagship X-ray telescope

    Science.gov Websites

    astronomy, taking its place in the fleet of "Great Observatories." Who we are NASA's Chandra X-ray astronomy, distances are measured in units of light years, where one light year is the distance that light gravity? The answer is still out there. By studying clusters of galaxies, X-ray astronomy is tackling this

  14. Diffraction leveraged modulation of X-ray pulses using MEMS-based X-ray optics

    DOEpatents

    Lopez, Daniel; Shenoy, Gopal; Wang, Jin; Walko, Donald A.; Jung, Il-Woong; Mukhopadhyay, Deepkishore

    2016-08-09

    A method and apparatus are provided for implementing Bragg-diffraction leveraged modulation of X-ray pulses using MicroElectroMechanical systems (MEMS) based diffractive optics. An oscillating crystalline MEMS device generates a controllable time-window for diffraction of the incident X-ray radiation. The Bragg-diffraction leveraged modulation of X-ray pulses includes isolating a particular pulse, spatially separating individual pulses, and spreading a single pulse from an X-ray pulse-train.

  15. 13.1 micrometers hard X-ray focusing by a new type monocapillary X-ray optic designed for common laboratory X-ray source

    NASA Astrophysics Data System (ADS)

    Sun, Xuepeng; zhang, Xiaoyun; Zhu, Yu; Wang, Yabing; Shang, Hongzhong; Zhang, Fengshou; Liu, Zhiguo; Sun, Tianxi

    2018-04-01

    A new type of monocapillary X-ray optic, called 'two bounces monocapillary X-ray optics' (TBMXO), is proposed for generating a small focal spot with high power-density gain for micro X-ray analysis, using a common laboratory X-ray source. TBMXO is consists of two parts: an ellipsoidal part and a tapered part. Before experimental testing, the TBMXO was simulated by the ray tracing method in MATLAB. The simulated results predicted that the proposed TBMXO would produce a smaller focal spot with higher power-density gain than the ellipsoidal monocapillary X-ray optic (EMXO). In the experiment, the TBMXO performance was tested by both an optical device and a Cu target X-ray tube with focal spot of 100 μm. The results indicated that the TBMXO had a slope error of 57.6 μrad and a 13.1 μm focal spot and a 1360 gain in power density were obtained.

  16. X-ray emission from galaxies - The distribution of low-luminosity X-ray sources in the Galactic Centre region

    NASA Astrophysics Data System (ADS)

    Heard, Victoria; Warwick, Robert

    2012-09-01

    We report a study of the extended X-ray emission observed in the Galactic Centre (GC) region based on archival XMM-Newton data. The GC diffuse emission can be decomposed into three distinct components: the emission from low-luminosity point sources; the fluorescence of (and reflection from) dense molecular material; and soft (kT ~1 keV), diffuse thermal plasma emission most likely energised by supernova explosions. Here, we examine the emission due to unresolved point sources. We show that this source component accounts for the bulk of the 6.7-keV and 6.9-keV line emission. We fit the surface brightness distribution evident in these lines with an empirical 2-d model, which we then compare with a prediction derived from a 3-d mass model for the old stellar population in the GC region. We find that the X-ray surface brightness declines more rapidly with angular offset from Sgr A* than the mass-model prediction. One interpretation is that the X-ray luminosity per solar mass characterising the GC source population is increasing towards the GC. Alternatively, some refinement of the mass-distribution within the nuclear stellar disc may be required. The unresolved X-ray source population is most likely dominated by magnetic CVs. We use the X-ray observations to set constraints on the number density of such sources in the GC region. Our analysis does not support the premise that the GC is pervaded by very hot (~ 7.5 keV) thermal plasma, which is truly diffuse in nature.

  17. X-Ray Exam: Hip

    MedlinePlus

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Hip KidsHealth / For Parents / X-Ray Exam: Hip What's in this article? What ... Have Questions Print What It Is A hip X-ray is a safe and painless test that ...

  18. X-Ray Exam: Forearm

    MedlinePlus

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Forearm KidsHealth / For Parents / X-Ray Exam: Forearm What's in this article? What ... Have Questions Print What It Is A forearm X-ray is a safe and painless test that ...

  19. X-Ray Exam: Ankle

    MedlinePlus

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Ankle KidsHealth / For Parents / X-Ray Exam: Ankle What's in this article? What ... Have Questions Print What It Is An ankle X-ray is a safe and painless test that ...

  20. X-Ray Exam: Foot

    MedlinePlus

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Foot KidsHealth / For Parents / X-Ray Exam: Foot What's in this article? What ... Have Questions Print What It Is A foot X-ray is a safe and painless test that ...

  1. X-Ray Exam: Wrist

    MedlinePlus

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Wrist KidsHealth / For Parents / X-Ray Exam: Wrist What's in this article? What ... Have Questions Print What It Is A wrist X-ray is a safe and painless test that ...

  2. X-Ray Exam: Finger

    MedlinePlus

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Finger KidsHealth / For Parents / X-Ray Exam: Finger What's in this article? What ... Have Questions Print What It Is A finger X-ray is a safe and painless test that ...

  3. X-Ray Exam: Pelvis

    MedlinePlus

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Pelvis KidsHealth / For Parents / X-Ray Exam: Pelvis What's in this article? What ... Have Questions Print What It Is A pelvis X-ray is a safe and painless test that ...

  4. X-ray based extensometry

    NASA Technical Reports Server (NTRS)

    Jordan, E. H.; Pease, D. M.

    1988-01-01

    A totally new method of extensometry using an X-ray beam was proposed. The intent of the method is to provide a non-contacting technique that is immune to problems associated with density variations in gaseous environments that plague optical methods. X-rays are virtually unrefractable even by solids. The new method utilizes X-ray induced X-ray fluorescence or X-ray induced optical fluorescence of targets that have melting temperatures of over 3000 F. Many different variations of the basic approaches are possible. In the year completed, preliminary experiments were completed which strongly suggest that the method is feasible. The X-ray induced optical fluorescence method appears to be limited to temperatures below roughly 1600 F because of the overwhelming thermal optical radiation. The X-ray induced X-ray fluorescence scheme appears feasible up to very high temperatures. In this system there will be an unknown tradeoff between frequency response, cost, and accuracy. The exact tradeoff can only be estimated. It appears that for thermomechanical tests with cycle times on the order of minutes a very reasonable system may be feasible. The intended applications involve very high temperatures in both materials testing and monitoring component testing. Gas turbine engines, rocket engines, and hypersonic vehicles (NASP) all involve measurement needs that could partially be met by the proposed technology.

  5. Association of X-ray arches with chromospheric neutral lines

    NASA Technical Reports Server (NTRS)

    Mcintosh, P. S.; Krieger, A. S.; Nolte, J. T.; Vaiana, G.

    1976-01-01

    Daily maps of magnetic neutral lines derived from H-alpha observations have been superimposed on solar X-ray images for the period from June 15 to 30, 1973. Nearly all X-ray-emitting structures consist of systems of arches covering chromospheric neutral lines. Areas of low emissivity, coronal holes, appear as the areas between arcades of arches. The presence of a coronal hole, therefore, is determined by the spacing between neutral lines and the scale of the arches over those neutral lines. X-ray emissivity on the solar disk extends from neutral lines in proportion to the vertical and horizontal scale of the arches over those neutral lines. Increasing scale of arches corresponds with increasing age of magnetic fields associated with the neutral line. All X-ray filament cavities coincided with neutral lines, but filaments appeared under cavities for only part of their length and for only a fraction of the disk passage.

  6. A new method to derive electronegativity from resonant inelastic x-ray scattering.

    PubMed

    Carniato, S; Journel, L; Guillemin, R; Piancastelli, M N; Stolte, W C; Lindle, D W; Simon, M

    2012-10-14

    Electronegativity is a well-known property of atoms and substituent groups. Because there is no direct way to measure it, establishing a useful scale for electronegativity often entails correlating it to another chemical parameter; a wide variety of methods have been proposed over the past 80 years to do just that. This work reports a new approach that connects electronegativity to a spectroscopic parameter derived from resonant inelastic x-ray scattering. The new method is demonstrated using a series of chlorine-containing compounds, focusing on the Cl 2p(-1)LUMO(1) electronic states reached after Cl 1s → LUMO core excitation and subsequent KL radiative decay. Based on an electron-density analysis of the LUMOs, the relative weights of the Cl 2p(z) atomic orbital contributing to the Cl 2p(3/2) molecular spin-orbit components are shown to yield a linear electronegativity scale consistent with previous approaches.

  7. A new method to derive electronegativity from resonant inelastic x-ray scattering

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carniato, S.; Journel, L.; Guillemin, R.

    2012-10-14

    Electronegativity is a well-known property of atoms and substituent groups. Because there is no direct way to measure it, establishing a useful scale for electronegativity often entails correlating it to another chemical parameter; a wide variety of methods have been proposed over the past 80 years to do just that. This work reports a new approach that connects electronegativity to a spectroscopic parameter derived from resonant inelastic x-ray scattering. The new method is demonstrated using a series of chlorine-containing compounds, focusing on the Cl 2p{sup -1}LUMO{sup 1} electronic states reached after Cl 1s{yields} LUMO core excitation and subsequent KL radiativemore » decay. Based on an electron-density analysis of the LUMOs, the relative weights of the Cl 2p{sub z} atomic orbital contributing to the Cl 2p{sub 3/2} molecular spin-orbit components are shown to yield a linear electronegativity scale consistent with previous approaches.« less

  8. Skinfold Prediction Equations Fail to Provide an Accurate Estimate of Body Composition in Elite Rugby Union Athletes of Caucasian and Polynesian Ethnicity.

    PubMed

    Zemski, Adam J; Broad, Elizabeth M; Slater, Gary J

    2018-01-01

    Body composition in elite rugby union athletes is routinely assessed using surface anthropometry, which can be utilized to provide estimates of absolute body composition using regression equations. This study aims to assess the ability of available skinfold equations to estimate body composition in elite rugby union athletes who have unique physique traits and divergent ethnicity. The development of sport-specific and ethnicity-sensitive equations was also pursued. Forty-three male international Australian rugby union athletes of Caucasian and Polynesian descent underwent surface anthropometry and dual-energy X-ray absorptiometry (DXA) assessment. Body fat percent (BF%) was estimated using five previously developed equations and compared to DXA measures. Novel sport and ethnicity-sensitive prediction equations were developed using forward selection multiple regression analysis. Existing skinfold equations provided unsatisfactory estimates of BF% in elite rugby union athletes, with all equations demonstrating a 95% prediction interval in excess of 5%. The equations tended to underestimate BF% at low levels of adiposity, whilst overestimating BF% at higher levels of adiposity, regardless of ethnicity. The novel equations created explained a similar amount of variance to those previously developed (Caucasians 75%, Polynesians 90%). The use of skinfold equations, including the created equations, cannot be supported to estimate absolute body composition. Until a population-specific equation is established that can be validated to precisely estimate body composition, it is advocated to use a proven method, such as DXA, when absolute measures of lean and fat mass are desired, and raw anthropometry data routinely to derive an estimate of body composition change.

  9. A Coordinated X-Ray and Optical Campaign of the Nearest Massive Eclipsing Binary, δ Orionis Aa. II. X-Ray Variability

    NASA Astrophysics Data System (ADS)

    Nichols, J.; Huenemoerder, D. P.; Corcoran, M. F.; Waldron, W.; Nazé, Y.; Pollock, A. M. T.; Moffat, A. F. J.; Lauer, J.; Shenar, T.; Russell, C. M. P.; Richardson, N. D.; Pablo, H.; Evans, N. R.; Hamaguchi, K.; Gull, T.; Hamann, W.-R.; Oskinova, L.; Ignace, R.; Hoffman, Jennifer L.; Hole, K. T.; Lomax, J. R.

    2015-08-01

    We present time-resolved and phase-resolved variability studies of an extensive X-ray high-resolution spectral data set of the δ Ori Aa binary system. The four observations, obtained with Chandra ACIS HETGS, have a total exposure time of ≈ 479 ks and provide nearly complete binary phase coverage. Variability of the total X-ray flux in the range of 5-25 Å is confirmed, with a maximum amplitude of about ±15% within a single ≈ 125 ks observation. Periods of 4.76 and 2.04 days are found in the total X-ray flux, as well as an apparent overall increase in the flux level throughout the nine-day observational campaign. Using 40 ks contiguous spectra derived from the original observations, we investigate the variability of emission line parameters and ratios. Several emission lines are shown to be variable, including S xv, Si xiii, and Ne ix. For the first time, variations of the X-ray emission line widths as a function of the binary phase are found in a binary system, with the smallest widths at ϕ = 0.0 when the secondary δ Ori Aa2 is at the inferior conjunction. Using 3D hydrodynamic modeling of the interacting winds, we relate the emission line width variability to the presence of a wind cavity created by a wind-wind collision, which is effectively void of embedded wind shocks and is carved out of the X-ray-producing primary wind, thus producing phase-locked X-ray variability. Based on data from the Chandra X-ray Observatory and the MOST satellite, a Canadian Space Agency mission, jointly operated by Dynacon Inc., the University of Toronto Institute of Aerospace Studies, and the University of British Columbia, with the assistance of the University of Vienna.

  10. Validity of Bioelectrical Impedance Analysis to Estimation Fat-Free Mass in the Army Cadets.

    PubMed

    Langer, Raquel D; Borges, Juliano H; Pascoa, Mauro A; Cirolini, Vagner X; Guerra-Júnior, Gil; Gonçalves, Ezequiel M

    2016-03-11

    Bioelectrical Impedance Analysis (BIA) is a fast, practical, non-invasive, and frequently used method for fat-free mass (FFM) estimation. The aims of this study were to validate predictive equations of BIA to FFM estimation in Army cadets and to develop and validate a specific BIA equation for this population. A total of 396 males, Brazilian Army cadets, aged 17-24 years were included. The study used eight published predictive BIA equations, a specific equation in FFM estimation, and dual-energy X-ray absorptiometry (DXA) as a reference method. Student's t-test (for paired sample), linear regression analysis, and Bland-Altman method were used to test the validity of the BIA equations. Predictive BIA equations showed significant differences in FFM compared to DXA (p < 0.05) and large limits of agreement by Bland-Altman. Predictive BIA equations explained 68% to 88% of FFM variance. Specific BIA equations showed no significant differences in FFM, compared to DXA values. Published BIA predictive equations showed poor accuracy in this sample. The specific BIA equations, developed in this study, demonstrated validity for this sample, although should be used with caution in samples with a large range of FFM.

  11. Panoramic images of white and black post-menopausal females evidencing carotid calcifications are at high risk of comorbid osteopenia of the femoral neck

    PubMed Central

    Friedlander, AH; Chang, TI; Aghazadehsanai, N; Berenji, GR; Harada, ND; Garrett, NR

    2013-01-01

    Objectives: Femoral neck fractures in older females resulting from decreased bone mineral density (BMD; osteopenia) are associated with increased morbidity and mortality. Bone mineralization inhibition is probably controlled by proteins which also foster vascular calcification. Therefore, we evaluated the relationship between calcified carotid artery plaque (CCAP) on panoramic images and BMD on dual energy X-ray absorptiometry (DXA) bone scans. Methods: Images and hospital records identified by dentists defined two study groups (20 white females and 24 black females) having CCAP and an incidentally obtained bone scan. Ethnically matched (age±7 years, body mass index ±3 units) control groups with panoramic images devoid of CCAP and accompanying DXA scan were likewise constituted. A physician determined the BMD on the DXA. Results: Females with CCAP had significantly (p = 0.03) poorer BMD at the femoral neck than those without CCAP. Although mean femoral neck BMD was significantly lower (p = 0.009) for white than for black females, there was no significant interaction between race and CCAP (p = 0.80). Conclusion: We observed a significant inverse association between the CCAP on panoramic images and femoral neck BMD in post-menopausal white females. PMID:23571481

  12. Panoramic images of white and black post-menopausal females evidencing carotid calcifications are at high risk of comorbid osteopenia of the femoral neck.

    PubMed

    Friedlander, A H; Chang, T I; Aghazadehsanai, N; Berenji, G R; Harada, N D; Garrett, N R

    2013-01-01

    Femoral neck fractures in older females resulting from decreased bone mineral density (BMD; osteopenia) are associated with increased morbidity and mortality. Bone mineralization inhibition is probably controlled by proteins which also foster vascular calcification. Therefore, we evaluated the relationship between calcified carotid artery plaque (CCAP) on panoramic images and BMD on dual energy X-ray absorptiometry (DXA) bone scans. Images and hospital records identified by dentists defined two study groups (20 white females and 24 black females) having CCAP and an incidentally obtained bone scan. Ethnically matched (age±7 years, body mass index ±3 units) control groups with panoramic images devoid of CCAP and accompanying DXA scan were likewise constituted. A physician determined the BMD on the DXA. Females with CCAP had significantly (p = 0.03) poorer BMD at the femoral neck than those without CCAP. Although mean femoral neck BMD was significantly lower (p = 0.009) for white than for black females, there was no significant interaction between race and CCAP (p = 0.80). We observed a significant inverse association between the CCAP on panoramic images and femoral neck BMD in post-menopausal white females.

  13. Applications of phase-contrast x-ray imaging to medicine using an x-ray interferometer

    NASA Astrophysics Data System (ADS)

    Momose, Atsushi; Yoneyama, Akio; Takeda, Tohoru; Itai, Yuji; Tu, Jinhong; Hirano, Keiichi

    1999-10-01

    We are investigating possible medical applications of phase- contrast X-ray imaging using an X-ray interferometer. This paper introduces the strategy of the research project and the present status. The main subject is to broaden the observation area to enable in vivo observation. For this purpose, large X-ray interferometers were developed, and 2.5 cm X 1.5 cm interference patterns were generated using synchrotron X-rays. An improvement of the spatial resolution is also included in the project, and an X-ray interferometer designed for high-resolution phase-contrast X-ray imaging was fabricated and tested. In parallel with the instrumental developments, various soft tissues are observed by phase- contrast X-ray CT to find correspondence between the generated contrast and our histological knowledge. The observation done so far suggests that cancerous tissues are differentiated from normal tissues and that blood can produce phase contrast. Furthermore, this project includes exploring materials that modulate phase contrast for selective imaging.

  14. Monte Carlo simulation of x-ray buildup factors of lead and its applications in shielding of diagnostic x-ray facilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kharrati, Hedi; Agrebi, Amel; Karaoui, Mohamed-Karim

    2007-04-15

    X-ray buildup factors of lead in broad beam geometry for energies from 15 to 150 keV are determined using the general purpose Monte Carlo N-particle radiation transport computer code (MCNP4C). The obtained buildup factors data are fitted to a modified three parameter Archer et al. model for ease in calculating the broad beam transmission with computer at any tube potentials/filters combinations in diagnostic energies range. An example for their use to compute the broad beam transmission at 70, 100, 120, and 140 kVp is given. The calculated broad beam transmission is compared to data derived from literature, presenting good agreement.more » Therefore, the combination of the buildup factors data as determined and a mathematical model to generate x-ray spectra provide a computationally based solution to broad beam transmission for lead barriers in shielding x-ray facilities.« less

  15. Frontiers of X-Ray Astronomy

    NASA Astrophysics Data System (ADS)

    Fabian, Andrew C.; Pounds, Kenneth A.; Blandford, Roger D.

    2004-07-01

    Preface; 1. Forty years on from Aerobee 150: a personal perspective K. Pounds; 2. X-ray spectroscopy of astrophysical plasmas S. M. Kahn, E. Behar, A. Kinkhabwala and D. W. Savin; 3. X-rays from stars M. Gudel; 4. X-ray observations of accreting white-dwarf systems M. Cropper, G. Ramsay, C. Hellier, K. Mukai, C. Mauche and D. Pandel; 5. Accretion flows in X-ray binaries C. Done; 6. Recent X-ray observations of supernova remnants C. R. Canizares; 7. Luminous X-ray sources in spiral and star-forming galaxies M. Ward; 8. Cosmological constraints from Chandra observations of galaxy clusters S. W. Allen; 9. Clusters of galaxies: a cosmological probe R. Mushotzky; 10. Obscured active galactic nuclei: the hidden side of the X-ray Universe G. Matt; 11. The Chandra Deep Field-North Survey and the cosmic X-ray background W. N. Brandt, D. M. Alexander, F. E. Bauer and A. E. Hornschemeier; 12. Hunting the first black holes G. Hasinger; 13. X-ray astronomy in the new millennium: a summary R. D. Blandford.

  16. X-ray laser microscope apparatus

    DOEpatents

    Suckewer, Szymon; DiCicco, Darrell S.; Hirschberg, Joseph G.; Meixler, Lewis D.; Sathre, Robert; Skinner, Charles H.

    1990-01-01

    A microscope consisting of an x-ray contact microscope and an optical microscope. The optical, phase contrast, microscope is used to align a target with respect to a source of soft x-rays. The source of soft x-rays preferably comprises an x-ray laser but could comprise a synchrotron or other pulse source of x-rays. Transparent resist material is used to support the target. The optical microscope is located on the opposite side of the transparent resist material from the target and is employed to align the target with respect to the anticipated soft x-ray laser beam. After alignment with the use of the optical microscope, the target is exposed to the soft x-ray laser beam. The x-ray sensitive transparent resist material whose chemical bonds are altered by the x-ray beam passing through the target mater GOVERNMENT LICENSE RIGHTS This invention was made with government support under Contract No. De-FG02-86ER13609 awarded by the Department of Energy. The Government has certain rights in this invention.

  17. Compound refractive X-ray lens

    DOEpatents

    Nygren, David R.; Cahn, Robert; Cederstrom, Bjorn; Danielsson, Mats; Vestlund, Jonas

    2000-01-01

    An apparatus and method for focusing X-rays. In one embodiment, his invention is a commercial-grade compound refractive X-ray lens. The commercial-grade compound refractive X-ray lens includes a volume of low-Z material. The volume of low-Z material has a first surface which is adapted to receive X-rays of commercially-applicable power emitted from a commercial-grade X-ray source. The volume of low-Z material also has a second surface from which emerge the X-rays of commercially-applicable power which were received at the first surface. Additionally, the commercial-grade compound refractive X-ray lens includes a plurality of openings which are disposed between the first surface and the second surface. The plurality of openings are oriented such that the X-rays of commercially-applicable power which are received at the first surface, pass through the volume of low-Z material and through the plurality openings. In so doing, the X-rays which emerge from the second surface are refracted to a focal point.

  18. Cosmic X-ray physics

    NASA Technical Reports Server (NTRS)

    Mccammon, D.; Cox, D. P.; Kraushaar, W. L.; Sanders, W. T.

    1985-01-01

    A progress report of research activities carried out in the area of cosmic X-ray physics is presented. The Diffuse X-ray Spectrometer DXS which has been flown twice as a rocket payload is described. The observation times proved to be too small for meaningful X-ray data to be obtained. Data collection and reduction activities from the Ultra-Soft X-ray background (UXT) instrument are described. UXT consists of three mechanically-collimated X-ray gas proportional counters with window/filter combinations which allow measurements in three energy bands, Be (80-110 eV), B (90-187 eV), and O (e84-532 eV). The Be band measurements provide an important constraint on local absorption of X-rays from the hot component of the local interstellar medium. Work has also continued on the development of a calorimetric detector for high-resolution spectroscopy in the 0.1 keV - 8keV energy range.

  19. X-ray (image)

    MedlinePlus

    X-rays are a form of electromagnetic radiation, just like visible light. Structures that are dense (such as bone) will block most of the x-ray particles, and will appear white. Metal and contrast media ( ...

  20. X-Ray Lasers

    ERIC Educational Resources Information Center

    Chapline, George; Wood, Lowell

    1975-01-01

    Outlines the prospects of generating coherent x rays using high-power lasers and indentifies problem areas in their development. Indicates possible applications for coherent x rays in the fields of chemistry, biology, and crystallography. (GS)

  1. Imaging properties and its improvements of scanning/imaging x-ray microscope

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Takeuchi, Akihisa, E-mail: take@spring8.or.jp; Uesugi, Kentaro; Suzuki, Yoshio

    A scanning / imaging X-ray microscope (SIXM) system has been developed at SPring-8. The SIXM consists of a scanning X-ray microscope with a one-dimensional (1D) X-ray focusing device and an imaging (full-field) X-ray microscope with a 1D X-ray objective. The motivation of the SIXM system is to realize a quantitative and highly-sensitive multimodal 3D X-ray tomography by taking advantages of both the scanning X-ray microscope using multi-pixel detector and the imaging X-ray microscope. Data acquisition process of a 2D image is completely different between in the horizontal direction and in the vertical direction; a 1D signal is obtained with themore » linear-scanning while the other dimensional signal is obtained with the imaging optics. Such condition have caused a serious problem on the imaging properties that the imaging quality in the vertical direction has been much worse than that in the horizontal direction. In this paper, two approaches to solve this problem will be presented. One is introducing a Fourier transform method for phase retrieval from one phase derivative image, and the other to develop and employ a 1D diffuser to produce an asymmetrical coherent illumination.« less

  2. Nonlinear X-Ray and Auger Spectroscopy at X-Ray Free-Electron Laser Sources

    NASA Astrophysics Data System (ADS)

    Rohringer, Nina

    2015-05-01

    X-ray free-electron lasers (XFELs) open the pathway to transfer non-linear spectroscopic techniques to the x-ray domain. A promising all x-ray pump probe technique is based on coherent stimulated electronic x-ray Raman scattering, which was recently demonstrated in atomic neon. By tuning the XFEL pulse to core-excited resonances, a few seed photons in the spectral tail of the XFEL pulse drive an avalanche of resonant inelastic x-ray scattering events, resulting in exponential amplification of the scattering signal by of 6-7 orders of magnitude. Analysis of the line profile of the emitted radiation permits to demonstrate the cross over from amplified spontaneous emission to coherent stimulated resonance scattering. In combination with statistical covariance mapping, a high-resolution spectrum of the resonant inelastic scattering process can be obtained, opening the path to coherent stimulated x-ray Raman spectroscopy. An extension of these ideas to molecules and a realistic feasibility study of stimulated electronic x-ray Raman scattering in CO will be presented. Challenges to realizing stimulated electronic x-ray Raman scattering at present-day XFEL sources will be discussed, corroborated by results of a recent experiment at the LCLS XFEL. Due to the small gain cross section in molecular targets, other nonlinear spectroscopic techniques such as nonlinear Auger spectroscopy could become a powerful alternative. Theory predictions of a novel pump probe technique based on resonant nonlinear Auger spectroscopic will be discussed and the method will be compared to stimulated x-ray Raman spectroscopy.

  3. Tunable X-ray source

    DOEpatents

    Boyce, James R [Williamsburg, VA

    2011-02-08

    A method for the production of X-ray bunches tunable in both time and energy level by generating multiple photon, X-ray, beams through the use of Thomson scattering. The method of the present invention simultaneously produces two X-ray pulses that are tunable in energy and/or time.

  4. X-Ray Diffraction Apparatus

    NASA Technical Reports Server (NTRS)

    Blake, David F. (Inventor); Bryson, Charles (Inventor); Freund, Friedmann (Inventor)

    1996-01-01

    An x-ray diffraction apparatus for use in analyzing the x-ray diffraction pattern of a sample is introduced. The apparatus includes a beam source for generating a collimated x-ray beam having one or more discrete x-ray energies, a holder for holding the sample to be analyzed in the path of the beam, and a charge-coupled device having an array of pixels for detecting, in one or more selected photon energy ranges, x-ray diffraction photons produced by irradiating such a sample with said beam. The CCD is coupled to an output unit which receives input information relating to the energies of photons striking each pixel in the CCD, and constructs the diffraction pattern of photons within a selected energy range striking the CCD.

  5. X-ray shearing interferometer

    DOEpatents

    Koch, Jeffrey A [Livermore, CA

    2003-07-08

    An x-ray interferometer for analyzing high density plasmas and optically opaque materials includes a point-like x-ray source for providing a broadband x-ray source. The x-rays are directed through a target material and then are reflected by a high-quality ellipsoidally-bent imaging crystal to a diffraction grating disposed at 1.times. magnification. A spherically-bent imaging crystal is employed when the x-rays that are incident on the crystal surface are normal to that surface. The diffraction grating produces multiple beams which interfere with one another to produce an interference pattern which contains information about the target. A detector is disposed at the position of the image of the target produced by the interfering beams.

  6. Abdominal x-ray

    MedlinePlus

    ... are, or may be, pregnant. Alternative Names Abdominal film; X-ray - abdomen; Flat plate; KUB x-ray ... Guidelines Viewers & Players MedlinePlus Connect for EHRs For Developers U.S. National Library of Medicine 8600 Rockville Pike, ...

  7. X-Ray Toolkit

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    2015-10-20

    Radiographic Image Acquisition & Processing Software for Security Markets. Used in operation of commercial x-ray scanners and manipulation of x-ray images for emergency responders including State, Local, Federal, and US Military bomb technicians and analysts.

  8. Soft x ray properties of the Geminga pulsar

    NASA Technical Reports Server (NTRS)

    Halpern, J. P.; Ruderman, M.

    1993-01-01

    The ROSAT soft x ray spectrum and pulse profile of the Geminga pulsar are analyzed and interpreted in terms of thermal emission from the surface of the neutron star. The x ray spectrum appears to consist of two blackbody components with T(sub 1) = (5.2 +/- 1.0) x 10 (exp 5) K and T(sub 2) approximately 3 x 10(exp 6) K, respectively. The inferred ratio of surface areas, A(sub 2)/A(sub 1), is approximately 3 x 10(exp -5). Both components are highly modulated at the pulsar rotation period, but the harder x ray pulse is narrower, and leads the main (soft) x ray pulse by about 105 deg of phase. The soft x ray component is interpreted as photospheric cooling of much of the neutron star's surface area, while the small, hot region could be part of the much smaller polar cap heated by energetic particles flowing inward from the magnetospheric accelerator which is responsible for the production of Geminga's gamma rays. Geminga's gamma ray emission is consistent with outer-magnetosphere accelerator models for highly inclined dipoles. These predict the beaming of energetic gamma rays close enough to the star to give copious e(+/-) production in the stellar magnetic field and a large circumstellar pair density from pair inflow toward the surface. These pairs may quench radio emission, and also reflect most of the hard polar cap x rays back to the stellar surface by cyclotron resonance scattering. They are then reemitted from that much larger area at the lower temperature T(sub 1). The single-peaked nature of the x ray pulse and its energy-dependent phase suggest an off-center dipole geometry for the surface magnetic field. Under the assumption that the soft x ray emission comes from the full surface of a neutron star of radius R = 10 km, a distance estimate of (150-400) pc is derived. This range is consistent with the fit interstellar column density of (1.5 +/- 0.5) x 10(exp 20) cm(exp -2). Distances less than 150 pc are probably ruled out both by the lower limit on the column

  9. Indus-2 X-ray lithography beamline for X-ray optics and material science applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dhamgaye, V. P., E-mail: vishal@rrcat.gov.in; Lodha, G. S., E-mail: vishal@rrcat.gov.in

    2014-04-24

    X-ray lithography is an ideal technique by which high aspect ratio and high spatial resolution micro/nano structures are fabricated using X-rays from synchrotron radiation source. The technique has been used for fabricating optics (X-ray, visible and infrared), sensors and actuators, fluidics and photonics. A beamline for X-ray lithography is operational on Indus-2. The beamline offers wide lithographic window from 1-40keV photon energy and wide beam for producing microstructures in polymers upto size ∼100mm × 100mm. X-ray exposures are possible in air, vacuum and He gas environment. The air based exposures enables the X-ray irradiation of resist for lithography and alsomore » irradiation of biological and liquid samples.« less

  10. X-ray vision of fuel sprays.

    PubMed

    Wang, Jin

    2005-03-01

    With brilliant synchrotron X-ray sources, microsecond time-resolved synchrotron X-ray radiography and tomography have been used to elucidate the detailed three-dimensional structure and dynamics of high-pressure high-speed fuel sprays in the near-nozzle region. The measurement allows quantitative determination of the fuel distribution in the optically impenetrable region owing to the multiple scattering of visible light by small atomized fuel droplets surrounding the jet. X-radiographs of the jet-induced shock waves prove that the fuel jets become supersonic under appropriate injection conditions and that the quantitative analysis of the thermodynamic properties of the shock waves can also be derived from the most direct measurement. In other situations where extremely axial-asymmetric sprays are encountered, mass deconvolution and cross-sectional fuel distribution models can be computed based on the monochromatic and time-resolved X-radiographic images collected from various rotational orientations of the sprays. Such quantitative analysis reveals the never-before-reported characteristics and most detailed near-nozzle mass distribution of highly transient fuel sprays.

  11. Compact x-ray source and panel

    DOEpatents

    Sampayon, Stephen E [Manteca, CA

    2008-02-12

    A compact, self-contained x-ray source, and a compact x-ray source panel having a plurality of such x-ray sources arranged in a preferably broad-area pixelized array. Each x-ray source includes an electron source for producing an electron beam, an x-ray conversion target, and a multilayer insulator separating the electron source and the x-ray conversion target from each other. The multi-layer insulator preferably has a cylindrical configuration with a plurality of alternating insulator and conductor layers surrounding an acceleration channel leading from the electron source to the x-ray conversion target. A power source is connected to each x-ray source of the array to produce an accelerating gradient between the electron source and x-ray conversion target in any one or more of the x-ray sources independent of other x-ray sources in the array, so as to accelerate an electron beam towards the x-ray conversion target. The multilayer insulator enables relatively short separation distances between the electron source and the x-ray conversion target so that a thin panel is possible for compactness. This is due to the ability of the plurality of alternating insulator and conductor layers of the multilayer insulators to resist surface flashover when sufficiently high acceleration energies necessary for x-ray generation are supplied by the power source to the x-ray sources.

  12. Evaluation of an X-Ray Dose Profile Derived from an Optically Stimulated Luminescent Dosimeter during Computed Tomographic Fluoroscopy.

    PubMed

    Hasegawa, Hiroaki; Sato, Masanori; Tanaka, Hiroshi

    2015-01-01

    The purpose of this study was to evaluate scatter radiation dose to the subject surface during X-ray computed tomography (CT) fluoroscopy using the integrated dose ratio (IDR) of an X-ray dose profile derived from an optically stimulated luminescent (OSL) dosimeter. We aimed to obtain quantitative evidence supporting the radiation protection methods used during previous CT fluoroscopy. A multislice CT scanner was used to perform this study. OSL dosimeters were placed on the top and the lateral side of the chest phantom so that the longitudinal direction of dosimeters was parallel to the orthogonal axis-to-slice plane for measurement of dose profiles in CT fluoroscopy. Measurement of fluoroscopic conditions was performed at 120 kVp and 80 kVp. Scatter radiation dose was evaluated by calculating the integrated dose determined by OSL dosimetry. The overall percent difference of the integrated doses between OSL dosimeters and ionization chamber was 5.92%. The ratio of the integrated dose of a 100-mm length area to its tails (-50 to -6 mm, 50 to 6 mm) was the lowest on the lateral side at 80 kVp and the highest on the top at 120 kVp. The IDRs for different measurement positions were larger at 120 kVp than at 80 kVp. Similarly, the IDRs for the tube voltage between the primary X-ray beam and scatter radiation was larger on the lateral side than on the top of the phantom. IDR evaluation suggested that the scatter radiation dose has a high dependence on the position and a low dependence on tube voltage relative to the primary X-ray beam for constant dose rate fluoroscopic conditions. These results provided quantitative evidence supporting the radiation protection methods used during CT fluoroscopy in previous studies.

  13. Evaluation of an X-Ray Dose Profile Derived from an Optically Stimulated Luminescent Dosimeter during Computed Tomographic Fluoroscopy

    PubMed Central

    Hasegawa, Hiroaki; Sato, Masanori; Tanaka, Hiroshi

    2015-01-01

    The purpose of this study was to evaluate scatter radiation dose to the subject surface during X-ray computed tomography (CT) fluoroscopy using the integrated dose ratio (IDR) of an X-ray dose profile derived from an optically stimulated luminescent (OSL) dosimeter. We aimed to obtain quantitative evidence supporting the radiation protection methods used during previous CT fluoroscopy. A multislice CT scanner was used to perform this study. OSL dosimeters were placed on the top and the lateral side of the chest phantom so that the longitudinal direction of dosimeters was parallel to the orthogonal axis-to-slice plane for measurement of dose profiles in CT fluoroscopy. Measurement of fluoroscopic conditions was performed at 120 kVp and 80 kVp. Scatter radiation dose was evaluated by calculating the integrated dose determined by OSL dosimetry. The overall percent difference of the integrated doses between OSL dosimeters and ionization chamber was 5.92%. The ratio of the integrated dose of a 100-mm length area to its tails (−50 to −6 mm, 50 to 6 mm) was the lowest on the lateral side at 80 kVp and the highest on the top at 120 kVp. The IDRs for different measurement positions were larger at 120 kVp than at 80 kVp. Similarly, the IDRs for the tube voltage between the primary X-ray beam and scatter radiation was larger on the lateral side than on the top of the phantom. IDR evaluation suggested that the scatter radiation dose has a high dependence on the position and a low dependence on tube voltage relative to the primary X-ray beam for constant dose rate fluoroscopic conditions. These results provided quantitative evidence supporting the radiation protection methods used during CT fluoroscopy in previous studies. PMID:26151914

  14. Preliminary study report: topological texture features extracted from standard radiographs of the heel bone are correlated with femoral bone mineral density

    NASA Astrophysics Data System (ADS)

    Boehm, H. F.; Lutz, J.; Koerner, M.; Notohamiprodjo, M.; Reiser, M.

    2009-02-01

    With the growing number of eldery patients in industrialized nations the incidence of geriatric, i.e. osteoporotic fractures is steadily on the rise. It is of great importance to understand the characteristics of hip fractures and to provide diagnostic tests for the assessment of an individual's fracture-risk that allow to take preventive action and give therapeutic advice. At present, bone-mineral-density (BMD) obtained from DXA (dual-energy x-ray-absorptiometry) is the clinical standard of reference for diagnosis and follow-up of osteoporosis. Since availability of DXA - other than that of clinical X-ray imaging - is usually restricted to specialized medical centers it is worth trying to implement alternative methods to estimate an individual's BMD. Radiographs of the peripheral skeleton, e.g. the ankle, range among the most ordered diagnostic procedures in surgery for exclusion or confirmation of fracture. It would be highly beneficial if - as a by-product of conventional imaging - one could obtain a quantitative parameter that is closely correlated with femoral BMD in addition to the original diagnostic information, e.g. fracture status at the peripheral site. Previous studies could demonstrate a correlation between calcaneal BMD and osteoporosis. The objective of our study was to test the hypothesis that topological analysis of calcaneal bone texture depicted by a lateral x-ray projection of the ankle allows to estimate femoral BMD. Our analysis on 34 post-menopausal patients indicate that texture properties based on graylevel topology in calcaneal x-ray-films are closely correlated with BMD at the hip and may qualify as a substitute indicator of femoral fracture risk.

  15. The Role of Body Fat and Fat Distribution in Hypertension Risk in Urban Black South African Women

    PubMed Central

    Crowther, Nigel J.; Jaff, Nicole G.; Kengne, Andre P.; Norris, Shane A.

    2016-01-01

    Developing countries are disproportionately affected by hypertension, with Black women being at greater risk, possibly due to differences in body fat distribution. The objectives of this study were: (1) To examine how different measures of body composition are associated with blood pressure (BP) and incident hypertension; (2) to determine the association between baseline or change in body composition, and hypertension; and (3) to determine which body composition measure best predicts hypertension in Black South African women. The sample comprised 478 non-hypertensive women, aged 29–53 years. Body fat and BP were assessed at baseline and 8.3 years later. Body composition was assessed using dual-energy X-ray absorptiometry (DXA) (n = 273) and anthropometry. Hypertension was diagnosed based on a systolic/diastolic BP ≥140/90 mmHg, or medication use at follow-up. All body composition measures increased (p<0.0001) between baseline and follow-up. SBP and DBP increased by ≥20%, resulting in a 57.1% cumulative incidence of hypertension. Both DXA- and anthropometric-derived measures of body composition were significantly associated with BP, explaining 3–5% of the variance. Baseline BP was the most important predictor of hypertension (adjusted OR: 98–123%). Measures of central adiposity were associated with greater odds (50–65%) of hypertension than total adiposity (44–45%). Only change in anthropometric-derived central fat mass predicted hypertension (adjusted OR: 32–40%). This study highlights that body composition is not a major determinant of hypertension in the sample of black African women. DXA measures of body composition do not add to hypertension prediction beyond anthropometry, which is especially relevant for African populations globally, taking into account the severely resource limited setting found in these communities. PMID:27171011

  16. The X-ray Halo of GX5-1

    NASA Technical Reports Server (NTRS)

    Smith, Randall K.; Dame, T. M.; Costantini, Elisa; Predehl, Peter

    2006-01-01

    Using Chandra observations we have measured the energy-resolved dust-scattered X-ray halo around the low-mass X-ray binary GX5-1, detecting for the first time multiply scattered X-rays from interstellar dust. % e compared the observed X-ray halo at various energies to predictions from a range of dust models. These fits used both smoothly-distributed dust as well as dust in clumped clouds, with CO and 21 cm observations helping to determine the position of the clouds along the line of sight. We found that the BARE-GR-B model of Zubko, Dwek & Arendt (2004) generally led to the best results, although inadequacies in both the overall model and the data limit our conclusions. We did find that the composite dust models of Zubko, Dwek & Arendt (2004), especially the "no carbon" models, gave uniformly poor results. Although models using cloud positions and densities derived naively from CO and 21 cm data gave generally poor results, plausible adjustments to the distance of the largest cloud and the mass of a cloud in the expanding 3 kpc Arm lead to significantly improved fits. We suggest that combining X-ray halo, CO, and 21 cm observations will be a fruitful method to improve our understanding of both the gas and dust phases of the interstellar medium.

  17. Symbiotic Stars in X-rays

    NASA Technical Reports Server (NTRS)

    Luna, G. J. M.; Sokoloski, J. L.; Mukai, K.; Nelson, T.

    2014-01-01

    Until recently, symbiotic binary systems in which a white dwarf accretes from a red giant were thought to be mainly a soft X-ray population. Here we describe the detection with the X-ray Telescope (XRT) on the Swift satellite of 9 white dwarf symbiotics that were not previously known to be X-ray sources and one that was previously detected as a supersoft X-ray source. The 9 new X-ray detections were the result of a survey of 41 symbiotic stars, and they increase the number of symbiotic stars known to be X-ray sources by approximately 30%. Swift/XRT detected all of the new X-ray sources at energies greater than 2 keV. Their X-ray spectra are consistent with thermal emission and fall naturally into three distinct groups. The first group contains those sources with a single, highly absorbed hard component, which we identify as probably coming from an accretion-disk boundary layer. The second group is composed of those sources with a single, soft X-ray spectral component, which likely arises in a region where low-velocity shocks produce X-ray emission, i.e. a colliding-wind region. The third group consists of those sources with both hard and soft X-ray spectral components. We also find that unlike in the optical, where rapid, stochastic brightness variations from the accretion disk typically are not seen, detectable UV flickering is a common property of symbiotic stars. Supporting our physical interpretation of the two X-ray spectral components, simultaneous Swift UV photometry shows that symbiotic stars with harder X-ray emission tend to have stronger UV flickering, which is usually associated with accretion through a disk. To place these new observations in the context of previous work on X-ray emission from symbiotic stars, we modified and extended the alpha/beta/gamma classification scheme for symbiotic-star X-ray spectra that was introduced by Muerset et al. based upon observations with the ROSAT satellite, to include a new sigma classification for sources with

  18. X-ray laser

    DOEpatents

    Nilsen, Joseph

    1991-01-01

    An X-ray laser (10) that lases between the K edges of carbon and oxygen, i.e. between 44 and 23 Angstroms, is provided. The laser comprises a silicon (12) and dysprosium (14) foil combination (16) that is driven by two beams (18, 20) of intense line focused (22, 24) optical laser radiation. Ground state nickel-like dysprosium ions (34) are resonantly photo-pumped to their upper X-ray laser state by line emission from hydrogen-like silicon ions (32). The novel X-ray laser should prove especially useful for the microscopy of biological specimens.

  19. Observation of femtosecond X-ray interactions with matter using an X-ray–X-ray pump–probe scheme

    PubMed Central

    Inoue, Ichiro; Inubushi, Yuichi; Sato, Takahiro; Tono, Kensuke; Katayama, Tetsuo; Kameshima, Takashi; Ogawa, Kanade; Togashi, Tadashi; Owada, Shigeki; Amemiya, Yoshiyuki; Tanaka, Takashi; Hara, Toru

    2016-01-01

    Resolution in the X-ray structure determination of noncrystalline samples has been limited to several tens of nanometers, because deep X-ray irradiation required for enhanced resolution causes radiation damage to samples. However, theoretical studies predict that the femtosecond (fs) durations of X-ray free-electron laser (XFEL) pulses make it possible to record scattering signals before the initiation of X-ray damage processes; thus, an ultraintense X-ray beam can be used beyond the conventional limit of radiation dose. Here, we verify this scenario by directly observing femtosecond X-ray damage processes in diamond irradiated with extraordinarily intense (∼1019 W/cm2) XFEL pulses. An X-ray pump–probe diffraction scheme was developed in this study; tightly focused double–5-fs XFEL pulses with time separations ranging from sub-fs to 80 fs were used to excite (i.e., pump) the diamond and characterize (i.e., probe) the temporal changes of the crystalline structures through Bragg reflection. It was found that the pump and probe diffraction intensities remain almost constant for shorter time separations of the double pulse, whereas the probe diffraction intensities decreased after 20 fs following pump pulse irradiation due to the X-ray–induced atomic displacement. This result indicates that sub-10-fs XFEL pulses enable conductions of damageless structural determinations and supports the validity of the theoretical predictions of ultraintense X-ray–matter interactions. The X-ray pump–probe scheme demonstrated here would be effective for understanding ultraintense X-ray–matter interactions, which will greatly stimulate advanced XFEL applications, such as atomic structure determination of a single molecule and generation of exotic matters with high energy densities. PMID:26811449

  20. X ray spectra of X Per. [oso-8 observations

    NASA Technical Reports Server (NTRS)

    Becker, R. H.; Boldt, E. A.; Holt, S. S.; Pravdo, S. H.; Robinson-Saba, J.; Serlemitsos, P. J.; Swank, J. H.

    1978-01-01

    The cosmic X-ray spectroscopy experiment on OSO-8 observed X Per for twenty days during two observations in Feb. 1976 and Feb. 1977. The spectrum of X Per varies in phase with its 13.9 min period, hardening significantly at X-ray minimum. Unlike other X-ray binary pulsar spectra, X Per's spectra do not exhibit iron line emission or strong absorption features. The data show no evidence for a 22 hour periodicity in the X-ray intensity of X Per. These results indicate that the X-ray emission from X Per may be originating from a neutron star in a low density region far from the optically identified Be star.

  1. A Coordinated X-Ray and Optical Campaign of the Nearest Massive Eclipsing Binary, Delta Orionis Aa. II. X-Ray Variability

    NASA Technical Reports Server (NTRS)

    Nichols, J.; Huenemoerder, D. P.; Corcoran, M. F.; Waldron, W.; Naze, Y.; Pollock, A. M. T.; Moffat, A. F. J.; Lauer, J.; Shenar, T.; Russell, C. M. P.; hide

    2015-01-01

    We present time-resolved and phase-resolved variability studies of an extensive X-ray high-resolution spectral data set of the delta Ori Aa binary system. The four observations, obtained with Chandra ACIS (Advanced CCD Imaging Spectrometer) HETGS (High Energy Transmission Grating), have a total exposure time approximately equal to 479 kiloseconds and provide nearly complete binary phase coverage. Variability of the total X-ray flux in the range of 5-25 angstroms is confirmed, with a maximum amplitude of about plus or minus15 percent within a single approximately equal to125 kiloseconds observation. Periods of 4.76 and 2.04 days are found in the total X-ray flux, as well as an apparent overall increase in the flux level throughout the nine-day observational campaign. Using 40 kiloseconds contiguous spectra derived from the original observations, we investigate the variability of emission line parameters and ratios. Several emission lines are shown to be variable, including S (sub XV), Si (sub XIII), and Ne (sub IX). For the first time, variations of the X-ray emission line widths as a function of the binary phase are found in a binary system, with the smallest widths at phi = 0.0 when the secondary delta Ori Aa2 is at the inferior conjunction. Using 3D hydrodynamic modeling of the interacting winds, we relate the emission line width variability to the presence of a wind cavity created by a wind-wind collision, which is effectively void of embedded wind shocks and is carved out of the X-ray-producing primary wind, thus producing phase-locked X-ray variability.

  2. Accretion and Outflows in X-ray Binaries: What's Really Going on During X-ray Quiescence

    NASA Astrophysics Data System (ADS)

    MacDonald, Rachel K. D.; Bailyn, Charles D.; Buxton, Michelle

    2015-01-01

    X-ray binaries, consisting of a star and a stellar-mass black hole, are wonderful laboratories for studying accretion and outflows. They evolve on timescales quite accessible to us, unlike their supermassive cousins, and allow the possibility of gaining a deeper understanding of these two common astrophysical processes. Different wavelength regimes reveal different aspects of the systems: radio emission is largely generated by outflows and jets, X-ray emission by inner accretion flows, and optical/infrared (OIR) emission by the outer disk and companion star. The search for relationships between these different wavelengths is thus an area of active research, aiming to reveal deeper connections between accretion and outflows.Initial evidence for a strong, tight correlation between radio and X-ray emission has weakened as further observations and newly-discovered sources have been obtained. This has led to discussions of multiple tracks or clusters, or the possibility that no overall relation exists for the currently-known population of X-ray binaries. Our ability to distinguish among these options is hampered by a relative lack of observations at lower luminosities, and especially of truly X-ray quiescent (non-outbursting) systems. Although X-ray binaries spend the bulk of their existence in quiescence, few quiescent sources have been observed and multiple observations of individual sources are largely nonexistent. Here we discuss new observations of the lowest-luminosity quiescent X-ray binary, A0620-00, and the place this object occupies in investigations of the radio/X-ray plane. For the first time, we also incorporate simultaneous OIR data with the radio and X-ray data.In December 2013 we took simultaneous observations of A0620-00 in the X-ray (Chandra), the radio (EVLA), and the OIR (SMARTS 1.3m). These X-ray and radio data allowed us to investigate similarities among quiescent X-ray binaries, and changes over time for this individual object, in the radio/X-ray

  3. The X-ray Spectral Evolution of eta Carinae as Seen by ASCA

    NASA Technical Reports Server (NTRS)

    Corcoran, M. F.; Fredericks, A. C.; Petre, R.; Swank, J. H.; Drake, S. A.; White, Nicholas E. (Technical Monitor)

    2000-01-01

    Using data from the ASCA X-ray observatory, we examine the variations in the X-ray spectrum of the supermassive star nu Carinae with an unprecedented combination of spatial and spectral resolution. We include data taken during the recent X-ray eclipse in 1997-1998, after recovery from the eclipse, and during and after an X-ray flare. We show that the eclipse variation in the X-ray spectrum is apparently confined to a decrease in the emission measure of the source. We compare our results with a simple colliding wind binary model and find that the observed spectral variations are only consistent, with the binary model if there is significant high-temperature emission far from the star and/or a substantial change in the temperature distribution of the hot plasma. If contamination in the 2-10 keV band is important, the observed eclipse spectrum requires an absorbing column in excess of 10(exp 24)/sq cm for consistency with the binary model, which may indicate an increase in the first derivative of M from nu Carinae near the time of periastron passage. The flare spectra are consistent with the variability seen in nearly simultaneous RXTE observations and thus confirm that nu Carinae itself is the source of the flare emission. The variation in the spectrum during the flare seems confined to a change in the source emission measure. By comparing 2 observations obtained at the same phase in different X-ray cycles, we find that the current, X-ray brightness of the source is slightly higher than the brightness of the source during the last cycle perhaps indicative of a long-term increase in the first derivative of M, not associated with the X-ray cycle.

  4. The WISSH quasars project. III. X-ray properties of hyper-luminous quasars

    NASA Astrophysics Data System (ADS)

    Martocchia, S.; Piconcelli, E.; Zappacosta, L.; Duras, F.; Vietri, G.; Vignali, C.; Bianchi, S.; Bischetti, M.; Bongiorno, A.; Brusa, M.; Lanzuisi, G.; Marconi, A.; Mathur, S.; Miniutti, G.; Nicastro, F.; Bruni, G.; Fiore, F.

    2017-12-01

    We performed a survey of the X-ray properties of 41 objects from the WISE/SDSS selected hyper-luminous (WISSH) quasars sample, which includes 86 broad-line quasars with bolometric luminosity LBol ≳ 2 × 1047 erg s-1 shining at z 2-4. We used both proprietary and archival Chandra and XMM-Newton observations. Twenty-one quasars have sufficient quality data to perform a spectroscopic analysis, while for the remaining sources, X-ray properties are derived through hardness-ratio analysis (apart for six sources that result to be undetected). The bulk ( 70%) of the detected WISSH quasars exhibit NH <5 × 1022 cm-2, in agreement with their optical Type 1 AGN classification. All but three quasars show unabsorbed 2-10 keV luminosities L2-10≥ 1045 erg s-1. Thanks to their extreme radiative output across the mid-IR-to-X-ray range, WISSH quasars therefore offer the opportunity to significantly extend and validate the existing relations involving L2-10. Specifically, we studied the X-ray luminosity as a function of (i) X-ray-to-optical (X/O) flux ratio; (ii) mid-IR luminosity (LMIR); (iii) LBol, and (iv) αOX versus 2500 Å luminosity. We find that the WISSH quasars show (i) unreported very low X/O ( <0.1) compared to typical AGN values; (ii) L2-10/LMIR ratios that are significantly smaller than those derived for AGN with lower luminosity; (iii) a large X-ray bolometric correction, kBol,X ≈ 100-1000; and (iv) steep -2≳αOX≳-1.7. These results lead to a scenario in which the X-ray emission of hyper-luminous quasars is relatively weaker compared to lower luminosity AGN. Models predict that such an X-ray weakness can be relevant for the acceleration of powerful high-ionization, emission-line-driven winds, which are commonly detected in the UV spectra of WISSH quasars and can, in turn, perturb the X-ray corona and weaken its emission. Accordingly, hyper-luminous quasars represent the ideal laboratory to study the link between the AGN energy output and wind acceleration

  5. Future Hard X-ray and Gamma-Ray Missions

    NASA Astrophysics Data System (ADS)

    Krawczynski, Henric; Physics of the Cosmos (PCOS) Gamma Ray Science Interest Group (GammaSIG) Team

    2017-01-01

    With four major NASA and ESA hard X-ray and gamma-ray missions in orbit (Swift, NuSTAR, INTEGRAL, and Fermi) hard X-ray and gamma-ray astronomy is making major contributions to our understanding of the cosmos. In this talk, I will summarize the current and upcoming activities of the Physics of the Cosmos Gamma Ray Science Interest Group and highlight a few of the future hard X-ray and gamma-ray mission discussed by the community. HK thanks NASA for the support through the awards NNX14AD19G and NNX16AC42G and for PCOS travel support.

  6. Unified Theory for Decoding the Signals from X-Ray Florescence and X-Ray Diffraction of Mixtures.

    PubMed

    Chung, Frank H

    2017-05-01

    For research and development or for solving technical problems, we often need to know the chemical composition of an unknown mixture, which is coded and stored in the signals of its X-ray fluorescence (XRF) and X-ray diffraction (XRD). X-ray fluorescence gives chemical elements, whereas XRD gives chemical compounds. The major problem in XRF and XRD analyses is the complex matrix effect. The conventional technique to deal with the matrix effect is to construct empirical calibration lines with standards for each element or compound sought, which is tedious and time-consuming. A unified theory of quantitative XRF analysis is presented here. The idea is to cancel the matrix effect mathematically. It turns out that the decoding equation for quantitative XRF analysis is identical to that for quantitative XRD analysis although the physics of XRD and XRF are fundamentally different. The XRD work has been published and practiced worldwide. The unified theory derives a new intensity-concentration equation of XRF, which is free from the matrix effect and valid for a wide range of concentrations. The linear decoding equation establishes a constant slope for each element sought, hence eliminating the work on calibration lines. The simple linear decoding equation has been verified by 18 experiments.

  7. Effects of X-Ray Dose On Rhizosphere Studies Using X-Ray Computed Tomography

    PubMed Central

    Zappala, Susan; Helliwell, Jonathan R.; Tracy, Saoirse R.; Mairhofer, Stefan; Sturrock, Craig J.; Pridmore, Tony; Bennett, Malcolm; Mooney, Sacha J.

    2013-01-01

    X-ray Computed Tomography (CT) is a non-destructive imaging technique originally designed for diagnostic medicine, which was adopted for rhizosphere and soil science applications in the early 1980s. X-ray CT enables researchers to simultaneously visualise and quantify the heterogeneous soil matrix of mineral grains, organic matter, air-filled pores and water-filled pores. Additionally, X-ray CT allows visualisation of plant roots in situ without the need for traditional invasive methods such as root washing. However, one routinely unreported aspect of X-ray CT is the potential effect of X-ray dose on the soil-borne microorganisms and plants in rhizosphere investigations. Here we aimed to i) highlight the need for more consistent reporting of X-ray CT parameters for dose to sample, ii) to provide an overview of previously reported impacts of X-rays on soil microorganisms and plant roots and iii) present new data investigating the response of plant roots and microbial communities to X-ray exposure. Fewer than 5% of the 126 publications included in the literature review contained sufficient information to calculate dose and only 2.4% of the publications explicitly state an estimate of dose received by each sample. We conducted a study involving rice roots growing in soil, observing no significant difference between the numbers of root tips, root volume and total root length in scanned versus unscanned samples. In parallel, a soil microbe experiment scanning samples over a total of 24 weeks observed no significant difference between the scanned and unscanned microbial biomass values. We conclude from the literature review and our own experiments that X-ray CT does not impact plant growth or soil microbial populations when employing a low level of dose (<30 Gy). However, the call for higher throughput X-ray CT means that doses that biological samples receive are likely to increase and thus should be closely monitored. PMID:23840640

  8. X-Ray Emission from Massive Stars in Cyg OB2

    NASA Astrophysics Data System (ADS)

    Rauw, G.; Nazé, Y.; Wright, N. J.; Drake, J. J.; Guarcello, M. G.; Prinja, R. K.; Peck, L. W.; Albacete Colombo, J. F.; Herrero, A.; Kobulnicky, H. A.; Sciortino, S.; Vink, J. S.

    2015-11-01

    We report on the analysis of the Chandra-ACIS data of O, B, and WR stars in the young association Cyg OB2. X-ray spectra of 49 O-stars, 54 B-stars, and 3 WR-stars are analyzed and for the brighter sources, the epoch dependence of the X-ray fluxes is investigated. The O-stars in Cyg OB2 follow a well-defined scaling relation between their X-ray and bolometric luminosities: {log}\\\\frac{{L}{{X}}}{{L}{bol}}=-7.2+/- 0.2. This relation is in excellent agreement with the one previously derived for the Carina OB1 association. Except for the brightest O-star binaries, there is no general X-ray overluminosity due to colliding winds in O-star binaries. Roughly half of the known B-stars in the surveyed field are detected, but they fail to display a clear relationship between LX and Lbol. Out of the three WR stars in Cyg OB2, probably only WR 144 is itself responsible for the observed level of X-ray emission, at a very low {log}\\\\frac{{L}{{X}}}{{L}{bol}}=-8.8+/- 0.2. The X-ray emission of the other two WR-stars (WR 145 and 146) is most probably due to their O-type companion along with a moderate contribution from a wind-wind interaction zone.

  9. The Relationship Between Solar Radio and Hard X-Ray Emission

    NASA Technical Reports Server (NTRS)

    White, S. M.; Benz, A. O.; Christe, S.; Farnik, F.; Kundu, M. R.; Mann, G.; Ning, Z.; Raulin, J.-P.; Silva-Valio, A. V. R.; Saint-Hilaire, P.; hide

    2011-01-01

    This review discusses the complementary relationship between radio and hard Xray observations of the Sun using primarily results from the era of the Reuven Ramaty High Energy Solar Spectroscopic Imager satellite. A primary focus of joint radio and hard X-ray studies of solar flares uses observations of nonthermal gyrosynchrotron emission at radio wavelengths and bremsstrahlung hard X-rays to study the properties of electrons accelerated in the main flare site, since it is well established that these two emissions show very similar temporal behavior. A quantitative prescription is given for comparing the electron energy distributions derived separately from the two wavelength ranges: this is an important application with the potential for measuring the magnetic field strength in the flaring region, and reveals significant differences between the electrons in different energy ranges. Examples of the use of simultaneous data from the two wavelength ranges to derive physical conditions are then discussed, including the case of microflares, and the comparison of images at radio and hard X-ray wavelengths is presented. There have been puzzling results obtained from observations of solar flares at millimeter and submillimeter wavelengths, and the comparison of these results with corresponding hard X-ray data is presented. Finally, the review discusses the association of hard X-ray releases with radio emission at decimeter and meter wavelengths, which is dominated by plasma emission (at lower frequencies) and electron cyclotron maser emission (at higher frequencies), both coherent emission mechanisms that require small numbers of energetic electrons. These comparisons show broad general associations but detailed correspondence remains more elusive.

  10. Phase-sensitive X-ray imager

    DOEpatents

    Baker, Kevin Louis

    2013-01-08

    X-ray phase sensitive wave-front sensor techniques are detailed that are capable of measuring the entire two-dimensional x-ray electric field, both the amplitude and phase, with a single measurement. These Hartmann sensing and 2-D Shear interferometry wave-front sensors do not require a temporally coherent source and are therefore compatible with x-ray tubes and also with laser-produced or x-pinch x-ray sources.

  11. Change in lean body mass is a major determinant of change in areal bone mineral density of the proximal femur: a 12-year observational study.

    PubMed

    Liu-Ambrose, T; Kravetsky, L; Bailey, D; Sherar, L; Mundt, C; Baxter-Jones, A; Khan, K M; McKay, H A

    2006-09-01

    Our objective was to assess the contribution of lean body mass (LBM) and fat body mass (FBM) to areal bone mineral density (aBMD) in women during the years surrounding menopause. We used a 12-year observational design. Participants included 75 Caucasian women who were premenopausal, 53 of whom were available for follow-up. There were two measurement periods: baseline and 12-year follow-up. At both measurement periods, bone mineral content and aBMD of the proximal femur, posterior-anterior lumbar spine, and total body was assessed using dual-energy X-ray absorptiometry (DXA). LBM and FBM were derived from the total-body scans. General health, including current menopausal status, hormone replace therapy use, medication use, and physical activity, was assessed by questionnaires. At the end of the study, 44% of the women were postmenopausal. After controlling for baseline aBMD, current menopausal status, and current hormone replacement therapy, we found that change in LBM was independently associated with change in aBMD of the proximal femur (P = 0.001). The cross-sectional analyses also indicated that LBM was a significant determinant of aBMD of all three DXA-scanned sites at both baseline and follow-up. These novel longitudinal data highlight the important contribution of LBM to the maintenance of proximal femur bone mass at a key time in women's life span, the years surrounding menopause.

  12. Synchrotron X-ray powder diffraction data of LASSBio-1515: A new N-acylhydrazone derivative compound

    NASA Astrophysics Data System (ADS)

    Costa, F. N.; Braz, D.; Ferreira, F. F.; da Silva, T. F.; Barreiro, E. J.; Lima, L. M.; Colaço, M. V.; Kuplich, L.; Barroso, R. C.

    2014-02-01

    In this work, synchrotron X-ray powder diffraction data allowed for a successful indexing of LASSBio-1515 compound, candidate to analgesic and anti-inflammatory activity. X-ray powder diffraction data collected in transmission and high-throughput geometries were used to analyze this compound. The X-ray wavelength of the synchrotron radiation used in this study was determined to be λ=1.55054 Å. LASSBio-1515 was found to be monoclinic with space group P21/c and unit cell parameters a=11.26255(16) Å, b=12.59785(16) Å, c=8.8540(1) Å, β=90.5972(7)° and V=1256.17(3) Å3.

  13. Pre-menarcheal physical activity predicts post-menarcheal lean mass and core strength, but not fat mass

    PubMed Central

    Day, M.A.; Dowthwaite, J.N.; Rosenbaum, P.F.; Roedel, G.G.; Brocker, A.A.; Scerpella, T.A.

    2015-01-01

    Objectives: Youth exercise is associated with improved body composition, but details regarding timing and persistence are limited. We examined pre- and circum-menarcheal organized physical activity exposure (PA) as a factor in development of early post-menarcheal lean mass, fat mass and muscle strength. Methods: Participants in a longitudinal study of musculoskeletal growth using dual energy X-ray absorptiometry (DXA) were included based on: 1) Whole body DXA scans: 0.5-1.5 years pre-menarche, 0.5-1.5 years post-menarche; 2) PA records for ≥6 months preceding the first DXA (PREPA) and for the inter-DXA interval (CIRCUMPA). Dominant arm grip strength and sit-ups tests coincided with DXA scans; PA, height and maturity were recorded semi-annually. Regressions correlated PA with lean mass/fat mass/strength, accounting for maturity, body size, and baseline values. Results Seventy girls [baseline: 11.8 yrs (sd 1.0), follow-up: 13.9 years (sd 1.0)] demonstrated circum-menarcheal gains of 25-29% for lean and fat mass and 33% for grip strength. PREPA correlated with pre- and post-menarcheal lean mass, sit-ups and pre-menarcheal fat mass (p<0.05), but not grip strength. CIRCUMPA correlated with only post-menarcheal sub-head lean mass (p=0.03). Conclusions: Lean mass and core strength at 1-year post-menarche were more strongly predicted by pre-menarcheal organized PA than by recent circum-menarcheal PA. PMID:26636280

  14. Toward Adaptive X-Ray Telescopes

    NASA Technical Reports Server (NTRS)

    O'Dell, Stephen L.; Atkins, Carolyn; Button, Tim W.; Cotroneo, Vincenzo; Davis, William N.; Doel, Peer; Feldman, Charlotte H.; Freeman, Mark D.; Gubarev, Mikhail V.; Kolodziejczak, Jeffrey J.; hide

    2011-01-01

    Future x-ray observatories will require high-resolution (less than 1 inch) optics with very-large-aperture (greater than 25 square meter) areas. Even with the next generation of heavy-lift launch vehicles, launch-mass constraints and aperture-area requirements will limit the surface areal density of the grazing-incidence mirrors to about 1 kilogram per square meter or less. Achieving sub-arcsecond x-ray imaging with such lightweight mirrors will require excellent mirror surfaces, precise and stable alignment, and exceptional stiffness or deformation compensation. Attaining and maintaining alignment and figure control will likely involve adaptive (in-space adjustable) x-ray optics. In contrast with infrared and visible astronomy, adaptive optics for x-ray astronomy is in its infancy. In the middle of the past decade, two efforts began to advance technologies for adaptive x-ray telescopes: The Generation-X (Gen-X) concept studies in the United States, and the Smart X-ray Optics (SXO) Basic Technology project in the United Kingdom. This paper discusses relevant technological issues and summarizes progress toward adaptive x-ray telescopes.

  15. Toward active x-ray telescopes

    NASA Astrophysics Data System (ADS)

    O'Dell, Stephen L.; Atkins, Carolyn; Button, Timothy W.; Cotroneo, Vincenzo; Davis, William N.; Doel, Peter; Feldman, Charlotte H.; Freeman, Mark D.; Gubarev, Mikhail V.; Kolodziejczak, Jeffery J.; Michette, Alan G.; Ramsey, Brian D.; Reid, Paul B.; Rodriguez Sanmartin, Daniel; Saha, Timo T.; Schwartz, Daniel A.; Trolier-McKinstry, Susan; Wilke, Rudeger H. T.; Willingale, Richard; Zhang, William W.

    2011-09-01

    Future x-ray observatories will require high-resolution (< 1") optics with very-large-aperture (> 25 m2) areas. Even with the next generation of heavy-lift launch vehicles, launch-mass constraints and aperture-area requirements will limit the areal density of the grazing-incidence mirrors to about 1 kg/m2 or less. Achieving sub-arcsecond x-ray imaging with such lightweight mirrors will require excellent mirror surfaces, precise and stable alignment, and exceptional stiffness or deformation compensation. Attaining and maintaining alignment and figure control will likely involve active (in-space adjustable) x-ray optics. In contrast with infrared and visible astronomy, active optics for x-ray astronomy is in its infancy. In the middle of the past decade, two efforts began to advance technologies for adaptive x-ray telescopes: The Smart X-ray Optics (SXO) Basic Technology project in the United Kingdom (UK) and the Generation-X (Gen-X) concept studies in the United States (US). This paper discusses relevant technological issues and summarizes progress toward active x-ray telescopes.

  16. Prospective evaluation of risk of vertebral fractures using quantitative ultrasound measurements and bone mineral density in a population-based sample of postmenopausal women: results of the Basel Osteoporosis Study.

    PubMed

    Hollaender, R; Hartl, F; Krieg, M-A; Tyndall, A; Geuckel, C; Buitrago-Tellez, C; Manghani, M; Kraenzlin, M; Theiler, R; Hans, D

    2009-03-01

    Prospective studies have shown that quantitative ultrasound (QUS) techniques predict the risk of fracture of the proximal femur with similar standardised risk ratios to dual-energy x-ray absorptiometry (DXA). Few studies have investigated these devices for the prediction of vertebral fractures. The Basel Osteoporosis Study (BOS) is a population-based prospective study to assess the performance of QUS devices and DXA in predicting incident vertebral fractures. 432 women aged 60-80 years were followed-up for 3 years. Incident vertebral fractures were assessed radiologically. Bone measurements using DXA (spine and hip) and QUS measurements (calcaneus and proximal phalanges) were performed. Measurements were assessed for their value in predicting incident vertebral fractures using logistic regression. QUS measurements at the calcaneus and DXA measurements discriminated between women with and without incident vertebral fracture, (20% height reduction). The relative risks (RRs) for vertebral fracture, adjusted for age, were 2.3 for the Stiffness Index (SI) and 2.8 for the Quantitative Ultrasound Index (QUI) at the calcaneus and 2.0 for bone mineral density at the lumbar spine. The predictive value (AUC (95% CI)) of QUS measurements at the calcaneus remained highly significant (0.70 for SI, 0.72 for the QUI, and 0.67 for DXA at the lumbar spine) even after adjustment for other confounding variables. QUS of the calcaneus and bone mineral density measurements were shown to be significant predictors of incident vertebral fracture. The RRs for QUS measurements at the calcaneus are of similar magnitude as for DXA measurements.

  17. Oxidized derivatives of Octopus vulgaris and Carcinus aestuarii hemocyanins at pH 7.5 and related models by x-ray absorption spectroscopy.

    PubMed Central

    Borghi, Elena; Solari, Pier Lorenzo; Beltramini, Mariano; Bubacco, Luigi; Di Muro, Paolo; Salvato, Benedetto

    2002-01-01

    The binuclear copper sites of the met and met-azido derivatives of Octopus vulgaris and Carcinus aestuarii hemocyanins at pH 7.5 were characterized by high-resolution x-ray absorption spectroscopy in the low energy region (XANES) and in the higher region (EXAFS). The accuracy of the analysis of the data was tested with two mononuclear and six binuclear copper(II) complexes of the poly(benzimidazole) ligand systems 2-BB, L-5,5 and L-6,6 (Casella et al., 1993, Inorg. Chem. 32:2056-2067; 1996, Inorg. Chem. 35:1101-1113). Their structural and reactivity properties are related to those of the protein's derivatives. The results obtained for those models with resolved x-ray structure (the 2-BB-aquo and azido mononuclear complexes, and the binuclear L-5,5 Cu(II)-bis(hydroxo) (Casella et al., unpublished)), extends the validity of our approach to the other poly(benzimidazole)-containing complexes and to the hemocyanin derivatives. Comparison between the protein's and the complexes' data, support a description of the met-derivatives as a five-coordinated O-bridged binuclear copper(II) center and favors, for both species, a bis(hydroxo) structure with a 3-A Cu-Cu distance. For O. vulgaris met-azido derivative a mu-1,3 bridging mode for the ligand appears the most likely. The structural situation of C. aestuarii met-azido-derivative is less clear: a mu-1,1 mode is favored, but a terminal mode cannot be excluded. PMID:12023249

  18. X-ray superbubbles

    NASA Technical Reports Server (NTRS)

    Cash, W.

    1983-01-01

    Four regions of the galaxy, the Cygnus Superbubble, the Eta Carina complex, the Orion/Eridanus complex, and the Gum Nebula, are discussed as examples of collective effects in the interstellar medium. All four regions share certain features, indicating a common structure. The selection effects which determine the observable X-ray properties of the superbubbles are discussed, and it is demonstrated that only a very few more in our Galaxy can be detected in X rays. X-ray observation of extragalactic superbubbles is shown to be possible but requires the capabilities of a large, high quality, AXAF class observatory.

  19. X-ray transmissive debris shield

    DOEpatents

    Spielman, R.B.

    1996-05-21

    An X-ray debris shield for use in X-ray lithography that is comprised of an X-ray window having a layer of low density foam exhibits increased longevity without a substantial increase in exposure time. The low density foam layer serves to absorb the debris emitted from the X-ray source and attenuate the shock to the window so as to reduce the chance of breakage. Because the foam is low density, the X-rays are hardly attenuated by the foam and thus the exposure time is not substantially increased.

  20. X-ray transmissive debris shield

    DOEpatents

    Spielman, Rick B.

    1996-01-01

    An X-ray debris shield for use in X-ray lithography that is comprised of an X-ray window having a layer of low density foam exhibits increased longevity without a substantial increase in exposure time. The low density foam layer serves to absorb the debris emitted from the X-ray source and attenuate the shock to the window so as to reduce the chance of breakage. Because the foam is low density, the X-rays are hardly attenuated by the foam and thus the exposure time is not substantially increased.

  1. Topological X-Rays Revisited

    ERIC Educational Resources Information Center

    Lynch, Mark

    2012-01-01

    We continue our study of topological X-rays begun in Lynch ["Topological X-rays and MRI's," iJMEST 33(3) (2002), pp. 389-392]. We modify our definition of a topological magnetic resonance imaging and give an affirmative answer to the question posed there: Can we identify a closed set in a box by defining X-rays to probe the interior and without…

  2. X-ray Crystallography Facility

    NASA Technical Reports Server (NTRS)

    2000-01-01

    Edward Snell, a National Research Council research fellow at NASA's Marshall Space Flight Center (MSFC), prepares a protein crystal for analysis by x-ray crystallography as part of NASA's structural biology program. The small, individual crystals are bombarded with x-rays to produce diffraction patterns, a map of the intensity of the x-rays as they reflect through the crystal.

  3. Proposed equations and reference values for calculating bone health in children and adolescent based on age and sex

    PubMed Central

    Gómez-Campos, Rossana; Andruske, Cynthia Lee; de Arruda, Miguel; Urra Albornoz, Camilo; Cossio-Bolaños, Marco

    2017-01-01

    Background The Dual Energy X-Ray Absorptiometry (DXA) is the gold standard for measuring BMD and bone mineral content (BMC). In general, DXA is ideal for pediatric use. However, the development of specific standards for particular geographic regions limits its use and application for certain socio-cultural contexts. Additionally, the anthropometry may be a low cost and easy to use alternative method in epidemiological contexts. The goal of our study was to develop regression equations for predicting bone health of children and adolescents based on anthropometric indicators to propose reference values based on age and sex. Methods 3020 students (1567 males and 1453 females) ranging in ages 4.0 to 18.9 were studied from the Maule Region (Chile). Anthropometric variables evaluated included: weight, standing height, sitting height, forearm length, and femur diameter. A total body scan (without the head) was conducted by means of the Dual Energy X-Ray Absorptiometry. Bone mineral density (BMD) and the bone mineral content (BMC) were also determined. Calcium consumption was controlled for by recording the intake of the three last days prior to the evaluation. Body Mass Index (BMI) was calculated, and somatic maturation was determined by using the years of peak growth rate (APHV). Results Four regression models were generated to calculate bone health: for males BMD = (R2 = 0.79) and BMC = (R2 = 0.84) and for the females BMD = (R2 = 0.76) and BMC = (R2 = 0.83). Percentiles were developed by using the LMS method (p3, p5, p15, p25, p50, p75, p85, p95 and p97). Conclusions Regression equations and reference curves were developed to assess the bone health of Chilean children and adolescents. These instruments help identify children with potential underlying problems in bone mineralization during the growth stage and biological maturation. PMID:28759569

  4. Proposed equations and reference values for calculating bone health in children and adolescent based on age and sex.

    PubMed

    Gómez-Campos, Rossana; Andruske, Cynthia Lee; Arruda, Miguel de; Urra Albornoz, Camilo; Cossio-Bolaños, Marco

    2017-01-01

    The Dual Energy X-Ray Absorptiometry (DXA) is the gold standard for measuring BMD and bone mineral content (BMC). In general, DXA is ideal for pediatric use. However, the development of specific standards for particular geographic regions limits its use and application for certain socio-cultural contexts. Additionally, the anthropometry may be a low cost and easy to use alternative method in epidemiological contexts. The goal of our study was to develop regression equations for predicting bone health of children and adolescents based on anthropometric indicators to propose reference values based on age and sex. 3020 students (1567 males and 1453 females) ranging in ages 4.0 to 18.9 were studied from the Maule Region (Chile). Anthropometric variables evaluated included: weight, standing height, sitting height, forearm length, and femur diameter. A total body scan (without the head) was conducted by means of the Dual Energy X-Ray Absorptiometry. Bone mineral density (BMD) and the bone mineral content (BMC) were also determined. Calcium consumption was controlled for by recording the intake of the three last days prior to the evaluation. Body Mass Index (BMI) was calculated, and somatic maturation was determined by using the years of peak growth rate (APHV). Four regression models were generated to calculate bone health: for males BMD = (R2 = 0.79) and BMC = (R2 = 0.84) and for the females BMD = (R2 = 0.76) and BMC = (R2 = 0.83). Percentiles were developed by using the LMS method (p3, p5, p15, p25, p50, p75, p85, p95 and p97). Regression equations and reference curves were developed to assess the bone health of Chilean children and adolescents. These instruments help identify children with potential underlying problems in bone mineralization during the growth stage and biological maturation.

  5. Flare Characteristics from X-ray Light Curves

    NASA Astrophysics Data System (ADS)

    Gryciuk, M.; Siarkowski, M.; Sylwester, J.; Gburek, S.; Podgorski, P.; Kepa, A.; Sylwester, B.; Mrozek, T.

    2017-06-01

    A new methodology is given to determine basic parameters of flares from their X-ray light curves. Algorithms are developed from the analysis of small X-ray flares occurring during the deep solar minimum of 2009, between Solar Cycles 23 and 24, observed by the Polish Solar Photometer in X-rays (SphinX) on the Complex Orbital Observations Near-Earth of Activity of the Sun-Photon (CORONAS- Photon) spacecraft. One is a semi-automatic flare detection procedure that gives start, peak, and end times for single ("elementary") flare events under the assumption that the light curve is a simple convolution of a Gaussian and exponential decay functions. More complex flares with multiple peaks can generally be described by a sum of such elementary flares. Flare time profiles in the two energy ranges of SphinX (1.16 - 1.51 keV, 1.51 - 15 keV) are used to derive temperature and emission measure as a function of time during each flare. The result is a comprehensive catalogue - the SphinX Flare Catalogue - which contains 1600 flares or flare-like events and is made available for general use. The methods described here can be applied to observations made by Geosynchronous Operational Environmental Satellites (GOES), the Reuven Ramaty High Energy Solar Spectroscopic Imager (RHESSI) and other broad-band spectrometers.

  6. X-ray lithography using holographic images

    DOEpatents

    Howells, Malcolm R.; Jacobsen, Chris

    1995-01-01

    A non-contact X-ray projection lithography method for producing a desired X-ray image on a selected surface of an X-ray-sensitive material, such as photoresist material on a wafer, the desired X-ray image having image minimum linewidths as small as 0.063 .mu.m, or even smaller. A hologram and its position are determined that will produce the desired image on the selected surface when the hologram is irradiated with X-rays from a suitably monochromatic X-ray source of a selected wavelength .lambda.. On-axis X-ray transmission through, or off-axis X-ray reflection from, a hologram may be used here, with very different requirements for monochromaticity, flux and brightness of the X-ray source. For reasonable penetration of photoresist materials by X-rays produced by the X-ray source, the wavelength X, is preferably chosen to be no more than 13.5 nm in one embodiment and more preferably is chosen in the range 1-5 nm in the other embodiment. A lower limit on linewidth is set by the linewidth of available microstructure writing devices, such as an electron beam.

  7. Development of polycapillary x-ray optics for x-ray spectroscopy

    NASA Astrophysics Data System (ADS)

    Adams, Bernhard W.; Attenkofer, Klaus; Bond, Justin L.; Craven, Christopher A.; Cremer, Till; O'Mahony, Aileen; Minot, Michael J.; Popecki, Mark A.

    2016-09-01

    Bundles of hollow glass capillaries can be tapered to produce quasi-focusing x-ray optics. These optics are known as Kumakhov lenses. These optics are interesting for lab-based sources because they can be used to collimate and concentrate x-rays originating from a point, such as a laser focus or an electron-beam focus in a microtube.

  8. X-ray Spectrometry.

    ERIC Educational Resources Information Center

    Markowicz, Andrzej A.; Van Grieken, Rene E.

    1984-01-01

    Provided is a selective literature survey of X-ray spectrometry from late 1981 to late 1983. Literature examined focuses on: excitation (photon and electron excitation and particle-induced X-ray emission; detection (wavelength-dispersive and energy-dispersive spectrometry); instrumentation and techniques; and on such quantitative analytical…

  9. Exploring the X-Ray Universe

    NASA Astrophysics Data System (ADS)

    Seward, Frederick D.; Charles, Philip A.

    1995-11-01

    Exploring the X-Ray Universe describes the view of the stars and galaxies that is obtained through X-ray telescopes. X-rays, which are invisible to human sight, are created in the cores of active galaxies, in cataclysmic stellar explosions, and in streams of gas expelled by the Sun and stars. The window on the heavens used by the X-ray astronomers shows the great drama of cosmic violence on the grandest scale.

    This account of X-ray astronomy incorporates the latest findings from several observatories operating in space. These include the Einstein Observatory operated by NASA, and the EXOSAT satellite of the European Space Agency. The book covers the entire field, with chapters on stars, supernova remnants, normal and active galaxies, clusters of galaxies, the diffuse X-ray background, and much more. The authors review basic principles, include the necessary historical background, and explain exactly what we know from X-ray observations of the Universe.

  10. X-ray imaging physics for nuclear medicine technologists. Part 1: Basic principles of x-ray production.

    PubMed

    Seibert, J Anthony

    2004-09-01

    The purpose is to review in a 4-part series: (i) the basic principles of x-ray production, (ii) x-ray interactions and data capture/conversion, (iii) acquisition/creation of the CT image, and (iv) operational details of a modern multislice CT scanner integrated with a PET scanner. Advances in PET technology have lead to widespread applications in diagnostic imaging and oncologic staging of disease. Combined PET/CT scanners provide the high-resolution anatomic imaging capability of CT with the metabolic and physiologic information by PET, to offer a significant increase in information content useful for the diagnostician and radiation oncologist, neurosurgeon, or other physician needing both anatomic detail and knowledge of disease extent. Nuclear medicine technologists at the forefront of PET should therefore have a good understanding of x-ray imaging physics and basic CT scanner operation, as covered by this 4-part series. After reading the first article on x-ray production, the nuclear medicine technologist will be familiar with (a) the physical characteristics of x-rays relative to other electromagnetic radiations, including gamma-rays in terms of energy, wavelength, and frequency; (b) methods of x-ray production and the characteristics of the output x-ray spectrum; (c) components necessary to produce x-rays, including the x-ray tube/x-ray generator and the parameters that control x-ray quality (energy) and quantity; (d) x-ray production limitations caused by heating and the impact on image acquisition and clinical throughput; and (e) a glossary of terms to assist in the understanding of this information.

  11. X-ray absorption spectroscopy: EXAFS (Extended X-ray Absorption Fine Structure) and XANES (X-ray Absorption Near Edge Structure)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alp, E.E.; Mini, S.M.; Ramanathan, M.

    1990-04-01

    The x-ray absorption spectroscopy (XAS) had been an essential tool to gather spectroscopic information about atomic energy level structure in the early decades of this century. It has also played an important role in the discovery and systematization of rare-earth elements. The discovery of synchrotron radiation in 1952, and later the availability of broadly tunable synchrotron based x-ray sources have revitalized this technique since the 1970's. The correct interpretation of the oscillatory structure in the x-ray absorption cross-section above the absorption edge by Sayers et. al. has transformed XAS from a spectroscopic tool to a structural technique. EXAFS (Extended X-raymore » Absorption Fine Structure) yields information about the interatomic distances, near neighbor coordination numbers, and lattice dynamics. An excellent description of the principles and data analysis techniques of EXAFS is given by Teo. XANES (X-ray Absorption Near Edge Structure), on the other hand, gives information about the valence state, energy bandwidth and bond angles. Today, there are about 50 experimental stations in various synchrotrons around the world dedicated to collecting x-ray absorption data from the bulk and surfaces of solids and liquids. In this chapter, we will give the basic principles of XAS, explain the information content of essentially two different aspects of the absorption process leading to EXAFS and XANES, and discuss the source and samples limitations.« less

  12. X-ray radiative transfer in protoplanetary disks. The role of dust and X-ray background fields

    NASA Astrophysics Data System (ADS)

    Rab, Ch.; Güdel, M.; Woitke, P.; Kamp, I.; Thi, W.-F.; Min, M.; Aresu, G.; Meijerink, R.

    2018-01-01

    Context. The X-ray luminosities of T Tauri stars are about two to four orders of magnitude higher than the luminosity of the contemporary Sun. As these stars are born in clusters, their disks are not only irradiated by their parent star but also by an X-ray background field produced by the cluster members. Aims: We aim to quantify the impact of X-ray background fields produced by young embedded clusters on the chemical structure of disks. Further, we want to investigate the importance of the dust for X-ray radiative transfer in disks. Methods: We present a new X-ray radiative transfer module for the radiation thermo-chemical disk code PRODIMO (PROtoplanetary DIsk MOdel), which includes X-ray scattering and absorption by both the gas and dust component. The X-ray dust opacities can be calculated for various dust compositions and dust-size distributions. For the X-ray radiative transfer we consider irradiation by the star and by X-ray background fields. To study the impact of X-rays on the chemical structure of disks we use the well established disk ionization tracers N2H+ and HCO+. Results: For evolved dust populations (e.g. grain growth), X-ray opacities are mostly dominated by the gas; only for photon energies E ≳ 5-10 keV do dust opacities become relevant. Consequently the local disk X-ray radiation field is only affected in dense regions close to the disk midplane. X-ray background fields can dominate the local X-ray disk ionization rate for disk radii r ≳ 20 au. However, the N2H+ and HCO+ column densities are only significantly affected in cases of low cosmic-ray ionization rates (≲10-19 s-1), or if the background flux is at least a factor of ten higher than the flux level of ≈10-5 erg cm-2 s-1 expected for clusters typical for the solar vicinity. Conclusions: Observable signatures of X-ray background fields in low-mass star-formation regions, like Taurus, are only expected for cluster members experiencing a strong X-ray background field (e.g. due to

  13. Advanced x-ray imaging spectrometer

    NASA Technical Reports Server (NTRS)

    Callas, John L. (Inventor); Soli, George A. (Inventor)

    1998-01-01

    An x-ray spectrometer that also provides images of an x-ray source. Coded aperture imaging techniques are used to provide high resolution images. Imaging position-sensitive x-ray sensors with good energy resolution are utilized to provide excellent spectroscopic performance. The system produces high resolution spectral images of the x-ray source which can be viewed in any one of a number of specific energy bands.

  14. X-Rays from Pluto

    NASA Image and Video Library

    2016-09-14

    The first detection of Pluto in X-rays has been made using NASA's Chandra X-ray Observatory in conjunction with observations from NASA's New Horizons spacecraft. As New Horizons approached Pluto in late 2014 and then flew by the planet during the summer of 2015, Chandra obtained data during four separate observations. During each observation, Chandra detected low-energy X-rays from the small planet. The main panel in this graphic is an optical image taken from New Horizons on its approach to Pluto, while the inset shows an image of Pluto in X-rays from Chandra. There is a significant difference in scale between the optical and X-ray images. New Horizons made a close flyby of Pluto but Chandra is located near the Earth, so the level of detail visible in the two images is very different. The Chandra image is 180,000 miles across at the distance of Pluto, but the planet is only 1,500 miles across. Pluto is detected in the X-ray image as a point source, showing the sharpest level of detail available for Chandra or any other X-ray observatory. This means that details over scales that are smaller than the X-ray source cannot be seen here. Detecting X-rays from Pluto is a somewhat surprising result given that Pluto - a cold, rocky world without a magnetic field - has no natural mechanism for emitting X-rays. However, scientists knew from previous observations of comets that the interaction between the gases surrounding such planetary bodies and the solar wind - the constant streams of charged particles from the sun that speed throughout the solar system -- can create X-rays. The researchers were particularly interested in learning more about the interaction between the gases in Pluto's atmosphere and the solar wind. The New Horizon spacecraft carries an instrument designed to measure that activity up-close -- Solar Wind Around Pluto (SWAP) -- and scientists examined that data and proposed that Pluto contains a very mild, close-in bowshock, where the solar wind first

  15. Innovative space x-ray telescopes

    NASA Astrophysics Data System (ADS)

    Hudec, R.; Inneman, A.; Pina, L.; Sveda, L.; Ticha, H.; Brozek, V.

    2017-11-01

    We report on the progress in innovative X-ray mirror development with focus on requirements of future X-ray astronomy space projects. Various future projects in X-ray astronomy and astrophysics will require large lightweight but highly accurate segments with multiple thin shells or foils. The large Wolter 1 grazing incidence multiple mirror arrays, the Kirkpatrick-Baez modules, as well as the large Lobster-Eye X-ray telescope modules in Schmidt arrangement may serve as examples. All these space projects will require high quality and light segmented shells (shaped, bent or flat foils) with high X-ray reflectivity and excellent mechanical stability.

  16. X-Ray Exam: Cervical Spine

    MedlinePlus

    ... through them and appear black. An X-ray technician takes the X-rays. Usually, three different pictures ... to tell her doctor and the X-ray technician. Procedure Although the procedure may take up to ...

  17. X-Rays, Pregnancy and You

    MedlinePlus

    ... and Procedures Medical Imaging Medical X-ray Imaging X-Rays, Pregnancy and You Share Tweet Linkedin Pin ... the decision with your doctor. What Kind of X-Rays Can Affect the Unborn Child? During most ...

  18. Deep Extragalactic X-Ray Surveys

    NASA Astrophysics Data System (ADS)

    Brandt, W. N.; Hasinger, G.

    2005-09-01

    Deep surveys of the cosmic X-ray background are reviewed in the context of observational progress enabled by the Chandra X-Ray Observatory and the X-Ray Multi-Mirror Mission-Newton. The sources found by deep surveys are described along with their redshift and luminosity distributions, and the effectiveness of such surveys at selecting active galactic nuclei (AGN) is assessed. Some key results from deep surveys are highlighted, including (a) measurements of AGN evolution and the growth of supermassive black holes, (b) constraints on the demography and physics of high-redshift AGN, (c) the X-ray AGN content of infrared and submillimeter galaxies, and (d) X-ray emission from distant starburst and normal galaxies. We also describe some outstanding problems and future prospects for deep extragalactic X-ray surveys.

  19. Validity of Predictive Equations for Resting Energy Expenditure Developed for Obese Patients: Impact of Body Composition Method

    PubMed Central

    Achamrah, Najate; Jésus, Pierre; Grigioni, Sébastien; Rimbert, Agnès; Petit, André; Déchelotte, Pierre; Folope, Vanessa; Coëffier, Moïse

    2018-01-01

    Predictive equations have been specifically developed for obese patients to estimate resting energy expenditure (REE). Body composition (BC) assessment is needed for some of these equations. We assessed the impact of BC methods on the accuracy of specific predictive equations developed in obese patients. REE was measured (mREE) by indirect calorimetry and BC assessed by bioelectrical impedance analysis (BIA) and dual-energy X-ray absorptiometry (DXA). mREE, percentages of prediction accuracy (±10% of mREE) were compared. Predictive equations were studied in 2588 obese patients. Mean mREE was 1788 ± 6.3 kcal/24 h. Only the Müller (BIA) and Harris & Benedict (HB) equations provided REE with no difference from mREE. The Huang, Müller, Horie-Waitzberg, and HB formulas provided a higher accurate prediction (>60% of cases). The use of BIA provided better predictions of REE than DXA for the Huang and Müller equations. Inversely, the Horie-Waitzberg and Lazzer formulas provided a higher accuracy using DXA. Accuracy decreased when applied to patients with BMI ≥ 40, except for the Horie-Waitzberg and Lazzer (DXA) formulas. Müller equations based on BIA provided a marked improvement of REE prediction accuracy than equations not based on BC. The interest of BC to improve REE predictive equations accuracy in obese patients should be confirmed. PMID:29320432

  20. Validity of Three-Dimensional Photonic Scanning Technique for Estimating Percent Body Fat.

    PubMed

    Shitara, K; Kanehisa, H; Fukunaga, T; Yanai, T; Kawakami, Y

    2013-01-01

    Three-dimensional photonic scanning (3DPS) was recently developed to measure dimensions of a human body surface. The purpose of this study was to explore the validity of body volume measured by 3DPS for estimating the percent body fat (%fat). Design, setting, participants, and measurement: The body volumes were determined by 3DPS in 52 women. The body volume was corrected for residual lung volume. The %fat was estimated from body density and compared with the corresponding reference value determined by the dual-energy x-ray absorptiometry (DXA). No significant difference was found for the mean values of %fat obtained by 3DPS (22.2 ± 7.6%) and DXA (23.5 ± 4.9%). The root mean square error of %fat between 3DPS and reference technique was 6.0%. For each body segment, there was a significant positive correlation between 3DPS- and DXA-values, although the corresponding value for the head was slightly larger in 3DPS than in DXA. Residual lung volume was negatively correlated with the estimated error in %fat. The body volume determined with 3DPS is potentially useful for estimating %fat. A possible strategy for enhancing the measurement accuracy of %fat might be to refine the protocol for preparing the subject's hair prior to scanning and to improve the accuracy in the measurement of residual lung volume.