Sample records for x-ray coronary angiography

  1. X-ray angiography systems.

    PubMed

    1993-11-01

    Despite the emergence of several alternative angiographic imaging techniques (i.e., magnetic resonance imaging, computed tomography, and ultrasound angiography), x-ray angiography remains the predominant vascular imaging modality, generating over $4 billion in revenue a year in U.S. hospitals. In this issue, we provide a brief overview of the various angiographic imaging techniques, comparing them with x-ray angiography, and discuss the clinical aspects of x-ray vascular imaging, including catheterization and clinical applications. Clinical, cost, usage, and legal issues related to contrast media are discussed in "Contrast Media: Ionic versus Nonionic and Low-osmolality Agents." We also provide a technical overview and selection guidance for a basic x-ray angiography imaging system, including the gantry and table system, x-ray generator, x-ray tube, image intensifier, video camera and display monitors, image-recording devices, and digital acquisition and processing systems. This issue also contains our Evaluation of the GE Advantx L/C cardiac angiography system and the GE Advantx AFM general-purpose angiography system; the AFM can be used for peripheral, pulmonary, and cerebral vascular studied, among others, and can also be configured for cardiac angiography. Many features of the Advantx L/C system, including generator characteristics and ease of use, also apply to the Advantx AFM as configured for cardiac angiography. Our ratings are based on the systems' ability to provide the best possible image quality for diagnosis and therapy while minimizing patient and personnel exposure to radiation, as well as its ability to minimize operator effort and inconvenience. Both units are rated Acceptable. In the Guidance Section, "Radiation Safety and Protection," we discuss the importance of keeping patient and personnel exposures to radiation as low as reasonably possible, especially in procedures such as cardiac catheterization, angiographic imaging for special procedures

  2. Mono-Energy Coronary Angiography with a Compact Synchrotron Source

    NASA Astrophysics Data System (ADS)

    Eggl, Elena; Mechlem, Korbinian; Braig, Eva; Kulpe, Stephanie; Dierolf, Martin; Günther, Benedikt; Achterhold, Klaus; Herzen, Julia; Gleich, Bernhard; Rummeny, Ernst; Noёl, Peter B.; Pfeiffer, Franz; Muenzel, Daniela

    2017-02-01

    X-ray coronary angiography is an invaluable tool for the diagnosis of coronary artery disease. However, the use of iodine-based contrast media can be contraindicated for patients who present with chronic renal insufficiency or with severe iodine allergy. These patients could benefit from a reduced contrast agent concentration, possibly achieved through application of a mono-energetic x-ray beam. While large-scale synchrotrons are impractical for daily clinical use, the technology of compact synchrotron sources strongly advanced during the last decade. Here we present a quantitative analysis of the benefits a compact synchrotron source can offer in coronary angiography. Simulated projection data from quasi-mono-energetic and conventional x-ray tube spectra is used for a CNR comparison. Results show that compact synchrotron spectra would allow for a significant reduction of contrast media. Experimentally, we demonstrate the feasibility of coronary angiography at the Munich Compact Light Source, the first commercial installation of a compact synchrotron source.

  3. Automated myocardial perfusion from coronary x-ray angiography

    NASA Astrophysics Data System (ADS)

    Storm, Corstiaan J.; Slump, Cornelis H.

    2010-03-01

    The purpose of our study is the evaluation of an algorithm to determine the physiological relevance of a coronary lesion as seen in a coronary angiogram. The aim is to extract as much as possible information from a standard coronary angiogram to decide if an abnormality, percentage of stenosis, as seen in the angiogram, results in physiological impairment of the blood supply of the region nourished by the coronary artery. Coronary angiography, still the golden standard, is used to determine the cause of angina pectoris based on the demonstration of an important stenose in a coronary artery. Dimensions of a lesion such as length and percentage of narrowing can at present easily be calculated by using an automatic computer algorithm such as Quantitative Coronary Angiography (QCA) techniques resulting in just anatomical information ignoring the physiological relevance of the lesion. In our study we analyze myocardial perfusion images in standard coronary angiograms in rest and in artificial hyperemic phases, using a drug e.g. papaverine intracoronary. Setting a Region of Interest (ROI) in the angiogram without overlying major vessels makes it possible to calculate contrast differences as a function of time, so called time-density curves, in the basal and hyperemic phases. In minimizing motion artifacts, end diastolic images are selected ECG based in basal and hyperemic phase in an identical ROI in the same angiographic projection. The development of new algorithms for calculating differences in blood supply in the region as set are presented together with the results of a small clinical case study using the standard angiographic procedure.

  4. Thomson scattering laser-electron X-ray source for reduction of patient radiation dose in interventional coronary angiography

    NASA Astrophysics Data System (ADS)

    Artyukov, I. A.; Dyachkov, N. V.; Feshchenko, R. M.; Polunina, A. V.; Popov, N. L.; Shvedunov, V. I.; Vinogradov, A. V.

    2017-05-01

    It was medical applications that stimulated F. Carrol in the early 1990s to start the research of on relativistic Thomson scattering X-ray sources, as a part of the infrastructure of the future society. The possibility to use such a source in interventional cardiology is discussed in this paper. The replacement of X-ray tube by relativistic Thomson scattering Xray source is predicted to lower the patient radiation dose by a factor of 3 while image quality remains the same. The required general characteristics of accelerator and laser units are found. They can be reached by existing technology. A semiempirical method for simulation of medical and technical parameters of interventional coronary angiography systems is suggested.

  5. Three-dimensional reconstruction of coronary stents in vivo based on motion compensated X-ray angiography

    NASA Astrophysics Data System (ADS)

    Schäfer, Dirk; Movassaghi, Babak; Grass, Michael; Schoonenberg, Gert; Florent, Raoul; Wink, Onno; Klein, Andrew J. P.; Chen, James Y.; Garcia, Joel; Messenger, John C.; Carroll, John D.

    2007-03-01

    The complete expansion of the stent during a percutaneous transluminal coronary angioplasty (PTCA) procedure is essential for treatment of a stenotic segment of a coronary artery. Inadequate expansion of the stent is a major predisposing factor to in-stent restenosis and acute thrombosis. Stents are positioned and deployed by fluoroscopic guidance. Although the current generation of stents are made of materials with some degree of radio-opacity to detect their location after deployment, proper stent expansion is hard to asses. In this work, we introduce a new method for the three-dimensional (3D) reconstruction of the coronary stents in-vivo utilizing two-dimensional projection images acquired during rotational angiography (RA). The acquisition protocol consist of a propeller rotation of the X-ray C-arm system of 180°, which ensures sufficient angular coverage for volume reconstruction. The angiographic projections were acquired at 30 frames per second resulting in 180 projections during a 7 second rotational run. The motion of the stent is estimated from the automatically tracked 2D coordinates of the markers on the balloon catheter. This information is used within a motion-compensated reconstruction algorithm. Therefore, projections from different cardiac phases and motion states can be used, resulting in improved signal-to-noise ratio of the stent. Results of 3D reconstructed coronary stents in vivo, with high spatial resolution are presented. The proposed method allows for a comprehensive and unique quantitative 3D assessment of stent expansion that rivals current X-ray and intravascular ultrasound techniques.

  6. Mono-energy coronary angiography with a compact light source

    NASA Astrophysics Data System (ADS)

    Eggl, Elena; Mechlem, Korbinian; Braig, Eva; Kulpe, Stephanie; Dierolf, Martin; Günther, Benedikt; Achterhold, Klaus; Herzen, Julia; Gleich, Bernhard; Rummeny, Ernst; Noël, Peter B.; Pfeiffer, Franz; Muenzel, Daniela

    2017-03-01

    While conventional x-ray tube sources reliably provide high-power x-ray beams for everyday clinical practice, the broad spectra that are inherent to these sources compromise the diagnostic image quality. For a monochromatic x-ray source on the other hand, the x-ray energy can be adjusted to optimal conditions with respect to contrast and dose. However, large-scale synchrotron sources impose high spatial and financial demands, making them unsuitable for clinical practice. During the last decades, research has brought up compact synchrotron sources based on inverse Compton scattering, which deliver a highly brilliant, quasi-monochromatic, tunable x-ray beam, yet fitting into a standard laboratory. One application that could benefit from the invention of these sources in clinical practice is coronary angiography. Being an important and frequently applied diagnostic tool, a high number of complications in angiography, such as renal failure, allergic reaction, or hyperthyroidism, are caused by the large amount of iodine-based contrast agent that is required for achieving sufficient image contrast. Here we demonstrate monochromatic angiography of a porcine heart acquired at the MuCLS, the first compact synchrotron source. By means of a simulation, the CNR in a coronary angiography image achieved with the quasi-mono-energetic MuCLS spectrum is analyzed and compared to a conventional x-ray-tube spectrum. The results imply that the improved CNR achieved with a quasi-monochromatic spectrum can allow for a significant reduction of iodine contrast material.

  7. Coronary angiography

    MedlinePlus

    ... Angiogram - coronary; Coronary artery disease - angiography; CAD - angiography; Angina - angiography; Heart disease - angiography ... Coronary angiography may be done if: You have angina for the first time. Your angina that is ...

  8. 3D multimodal cardiac data reconstruction using angiography and computerized tomographic angiography registration.

    PubMed

    Moosavi Tayebi, Rohollah; Wirza, Rahmita; Sulaiman, Puteri S B; Dimon, Mohd Zamrin; Khalid, Fatimah; Al-Surmi, Aqeel; Mazaheri, Samaneh

    2015-04-22

    Computerized tomographic angiography (3D data representing the coronary arteries) and X-ray angiography (2D X-ray image sequences providing information about coronary arteries and their stenosis) are standard and popular assessment tools utilized for medical diagnosis of coronary artery diseases. At present, the results of both modalities are individually analyzed by specialists and it is difficult for them to mentally connect the details of these two techniques. The aim of this work is to assist medical diagnosis by providing specialists with the relationship between computerized tomographic angiography and X-ray angiography. In this study, coronary arteries from two modalities are registered in order to create a 3D reconstruction of the stenosis position. The proposed method starts with coronary artery segmentation and labeling for both modalities. Then, stenosis and relevant labeled artery in X-ray angiography image are marked by a specialist. Proper control points for the marked artery in both modalities are automatically detected and normalized. Then, a geometrical transformation function is computed using these control points. Finally, this function is utilized to register the marked artery from the X-ray angiography image on the computerized tomographic angiography and get the 3D position of the stenosis lesion. The result is a 3D informative model consisting of stenosis and coronary arteries' information from the X-ray angiography and computerized tomographic angiography modalities. The results of the proposed method for coronary artery segmentation, labeling and 3D reconstruction are evaluated and validated on the dataset containing both modalities. The advantage of this method is to aid specialists to determine a visual relationship between the correspondent coronary arteries from two modalities and also set up a connection between stenosis points from an X-ray angiography along with their 3D positions on the coronary arteries from computerized

  9. Respiratory motion estimation in x-ray angiography for improved guidance during coronary interventions

    NASA Astrophysics Data System (ADS)

    Baka, N.; Lelieveldt, B. P. F.; Schultz, C.; Niessen, W.; van Walsum, T.

    2015-05-01

    During percutaneous coronary interventions (PCI) catheters and arteries are visualized by x-ray angiography (XA) sequences, using brief contrast injections to show the coronary arteries. If we could continue visualizing the coronary arteries after the contrast agent passed (thus in non-contrast XA frames), we could potentially lower contrast use, which is advantageous due to the toxicity of the contrast agent. This paper explores the possibility of such visualization in mono-plane XA acquisitions with a special focus on respiratory based coronary artery motion estimation. We use the patient specific coronary artery centerlines from pre-interventional 3D CTA images to project on the XA sequence for artery visualization. To achieve this, a framework for registering the 3D centerlines with the mono-plane 2D + time XA sequences is presented. During the registration the patient specific cardiac and respiratory motion is learned. We investigate several respiratory motion estimation strategies with respect to accuracy, plausibility and ease of use for motion prediction in XA frames with and without contrast. The investigated strategies include diaphragm motion based prediction, and respiratory motion extraction from the guiding catheter tip motion. We furthermore compare translational and rigid respiratory based heart motion. We validated the accuracy of the 2D/3D registration and the respiratory and cardiac motion estimations on XA sequences of 12 interventions. The diaphragm based motion model and the catheter tip derived motion achieved 1.58 mm and 1.83 mm median 2D accuracy, respectively. On a subset of four interventions we evaluated the artery visualization accuracy for non-contrast cases. Both diaphragm, and catheter tip based prediction performed similarly, with about half of the cases providing satisfactory accuracy (median error < 2 mm).

  10. Real-time fusion of coronary CT angiography with x-ray fluoroscopy during chronic total occlusion PCI.

    PubMed

    Ghoshhajra, Brian B; Takx, Richard A P; Stone, Luke L; Girard, Erin E; Brilakis, Emmanouil S; Lombardi, William L; Yeh, Robert W; Jaffer, Farouc A

    2017-06-01

    The purpose of this study was to demonstrate the feasibility of real-time fusion of coronary computed tomography angiography (CTA) centreline and arterial wall calcification with x-ray fluoroscopy during chronic total occlusion (CTO) percutaneous coronary intervention (PCI). Patients undergoing CTO PCI were prospectively enrolled. Pre-procedural CT scans were integrated with conventional coronary fluoroscopy using prototype software. We enrolled 24 patients who underwent CTO PCI using the prototype CT fusion software, and 24 consecutive CTO PCI patients without CT guidance served as a control group. Mean age was 66 ± 11 years, and 43/48 patients were men. Real-time CTA fusion during CTO PCI provided additional information regarding coronary arterial calcification and tortuosity that generated new insights into antegrade wiring, antegrade dissection/reentry, and retrograde wiring during CTO PCI. Overall CTO success rates and procedural outcomes remained similar between the two groups, despite a trend toward higher complexity in the fusion CTA group. This study demonstrates that real-time automated co-registration of coronary CTA centreline and calcification onto live fluoroscopic images is feasible and provides new insights into CTO PCI, and in particular, antegrade dissection reentry-based CTO PCI. • Real-time semi-automated fusion of CTA/fluoroscopy is feasible during CTO PCI. • CTA fusion data can be toggled on/off as desired during CTO PCI • Real-time CT calcium and centreline overlay could benefit antegrade dissection/reentry-based CTO PCI.

  11. Contrast agent choice for intravenous coronary angiography

    NASA Astrophysics Data System (ADS)

    Zeman, H. D.; Siddons, D. P.

    1990-05-01

    The screening of the general population for coronary artery disease would be practical if a method existed for visualizing the extent of occlusion after an intravenous injection of contrast agent. Measurements performed with monochromatic synchrotron radiation X-rays and an iodine-containing contrast agent at the Stanford Synchrotron Radiation Laboratory have shown that such an intravenous angiography procedure would be possible with an adequately intense monochromatic X-ray source. Because of the size and cost of synchrotron radiation facilities it would be desirable to make the most efficient use of the intensity available, while reducing as much as possible the radiation dose experienced by the patient. By choosing contrast agents containing elements with a higher atomic number than iodine, it is possible to both improve the image quality and reduce the patient radiation dose, while using the same synchrotron radiation source. By using Si monochromator crystals with a small mosaic spread, it is possible to increase the X-ray flux available for imaging by over an order of magnitude, without any changes in the storage ring or wiggler magnet. The most critical imaging task for intravenous coronary angiography utilizing synchrotron radiation X-rays is visualizing a coronary artery through the left ventricle or aorta which also contain contrast agent. Calculations have been made of the signal to noise ratio expected for this imaging task for various contrast agents with atomic numbers between that of iodine and bismuth. The X-ray energy spectrum of the X-17 superconduction wiggler beam line at the National Synchrotron Light Source at Brookhaven National Laboratory has been used for these calculations. Both perfect Si crystals and Si crystals with a small mosaic spread are considered as monochromators. Contrast agents containing Gd or Yb seem to have about the optimal calculated signal to noise ratio. Gd-DTPA is already approved for use as a contrast agent for

  12. When is rotational angiography superior to conventional single-plane angiography for planning coronary angioplasty?

    PubMed

    Morris, Paul D; Taylor, Jane; Boutong, Sara; Brett, Sarah; Louis, Amal; Heppenstall, James; Morton, Allison C; Gunn, Julian P

    2016-03-01

    To investigate the value of rotational coronary angiography (RoCA) in the context of percutaneous coronary intervention (PCI) planning. As a diagnostic tool, RoCA is associated with decreased patient irradiation and contrast use compared with conventional coronary angiography (CA) and provides superior appreciation of three-dimensional anatomy. However, its value in PCI remains unknown. We studied stable coronary artery disease assessment and PCI planning by interventional cardiologists. Patients underwent either RoCA or conventional CA pre-PCI for planning. These were compared with the referral CA (all conventional) in terms of quantitative lesion assessment and operator confidence. An independent panel reanalyzed all parameters. Six operators performed 127 procedures (60 RoCA, 60 conventional CA, and 7 crossed-over) and assessed 212 lesions. RoCA was associated with a reduction in the number of lesions judged to involve a bifurcation (23 vs. 30 lesions, P < 0.05) and a reduction in the assessment of vessel caliber (2.8 vs. 3.0 mm, P < 0.05). RoCA improved confidence assessing lesion length (P = 0.01), percentage stenosis (P = 0.02), tortuosity (P < 0.04), and proximity to a bifurcation (P = 0.03), particularly in left coronary artery cases. X-ray dose, contrast agent volume, and procedure duration were not significantly different. Compared with conventional CA, RoCA augments quantitative lesion assessment, enhances confidence in the assessment of coronary artery disease and the precise details of the proposed procedure, but does not affect X-ray dose, contrast agent volume, or procedure duration. © 2015 The Authors. Catheterization and Cardiovascular Interventions. Published by Wiley Periodicals, Inc.

  13. Multiresolution image registration in digital x-ray angiography with intensity variation modeling.

    PubMed

    Nejati, Mansour; Pourghassem, Hossein

    2014-02-01

    Digital subtraction angiography (DSA) is a widely used technique for visualization of vessel anatomy in diagnosis and treatment. However, due to unavoidable patient motions, both externally and internally, the subtracted angiography images often suffer from motion artifacts that adversely affect the quality of the medical diagnosis. To cope with this problem and improve the quality of DSA images, registration algorithms are often employed before subtraction. In this paper, a novel elastic registration algorithm for registration of digital X-ray angiography images, particularly for the coronary location, is proposed. This algorithm includes a multiresolution search strategy in which a global transformation is calculated iteratively based on local search in coarse and fine sub-image blocks. The local searches are accomplished in a differential multiscale framework which allows us to capture both large and small scale transformations. The local registration transformation also explicitly accounts for local variations in the image intensities which incorporated into our model as a change of local contrast and brightness. These local transformations are then smoothly interpolated using thin-plate spline interpolation function to obtain the global model. Experimental results with several clinical datasets demonstrate the effectiveness of our algorithm in motion artifact reduction.

  14. Computational fluid dynamics comparisons of wall shear stress in patient-specific coronary artery bifurcation using coronary angiography and optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Poon, Eric; Thondapu, Vikas; Chin, Cheng; Scheerlinck, Cedric; Zahtila, Tony; Mamon, Chris; Nguyen, Wilson; Ooi, Andrew; Barlis, Peter

    2016-11-01

    Blood flow dynamics directly influence biology of the arterial wall, and are closely linked with the development of coronary artery disease. Computational fluid dynamics (CFD) solvers may be employed to analyze the hemodynamic environment in patient-specific reconstructions of coronary arteries. Although coronary X-ray angiography (CA) is the most common medical imaging modality for 3D arterial reconstruction, models reconstructed from CA assume a circular or elliptical cross-sectional area. This limitation can be overcome with a reconstruction technique fusing CA with intravascular optical coherence tomography (OCT). OCT scans the interior of an artery using near-infrared light, achieving a 10-micron resolution and providing unprecedented detail of vessel geometry. We compared 3D coronary artery bifurcation models generated using CA alone versus OCT-angiography fusion. The model reconstructed from CA alone is unable to identify the detailed geometrical variations of diseased arteries, and also under-estimates the cross-sectional vessel area compared to OCT-angiography fusion. CFD was performed in both models under pulsatile flow in order to identify and compare regions of low wall shear stress, a hemodynamic parameter directly linked with progression of atherosclerosis. Supported by ARC LP150100233 and VLSCI VR0210.

  15. Fairness in the coronary angiography queue.

    PubMed

    Alter, D A; Basinski, A S; Cohen, E A; Naylor, C D

    1999-10-05

    Since waiting lists for coronary angiography are generally managed without explicit queuing criteria, patients may not receive priority on the basis of clinical acuity. The objective of this study was to examine clinical and nonclinical determinants of the length of time patients wait for coronary angiography. In this single-centre prospective cohort study conducted in the autumn of 1997, 357 consecutive patients were followed from initial triage until a coronary angiography was performed or an adverse cardiac event occurred. The referring physicians' hospital affiliation (physicians at Sunnybrook & Women's College Health Sciences Centre, those who practice at another centre but perform angiography at Sunnybrook and those with no previous association with Sunnybrook) was used to compare processes of care. A clinical urgency rating scale was used to assign a recommended maximum waiting time (RMWT) to each patient retrospectively, but this was not used in the queuing process. RMWTs and actual waiting times for patients in the 3 referral groups were compared; the influence clinical and nonclinical variables had on the actual length of time patients waited for coronary angiography was assessed; and possible predictors of adverse events were examined. Of 357 patients referred to Sunnybrook, 22 (6.2%) experienced adverse events while in the queue. Among those who remained, 308 (91.9%) were in need of coronary angiography; 201 (60.0%) of those patients received one within the RMWT. The length of time to angiography was influenced by clinical characteristics similar to those specified on the urgency rating scale, leading to a moderate agreement between actual waiting times and RMWTs (kappa = 0.53). However, physician affiliation was a highly significant (p < 0.001) and independent predictor of waiting time. Whereas 45.6% of the variation in waiting time was explained by all clinical factors combined, 9.3% of the variation was explained by physician affiliation alone

  16. Evaluation of meglumine gadoterate-enhanced MR angiography (MRA) compared with time-of-flight MRA in the diagnosis of clinically significant non-coronary arterial disease: a pooled analysis of data from two clinical trials

    PubMed Central

    Shah, D J; Lim, T-H

    2012-01-01

    Objectives We analysed pooled data from two clinical trials to assess the diagnostic accuracy and safety of meglumine gadoterate (Gd-DOTA)-enhanced MR angiography (MRA) relative to those of non-enhanced time-of-flight (TOF) MRA for non-coronary arterial disease. Both techniques were compared with X-ray angiography as the gold standard. Methods Patients were of both sexes, were aged at least 18 years and had suspected non-coronary arterial disease. Each patient was his/her own control and underwent TOF MRA followed by Gd-DOTA-enhanced MRA, and then X-ray angiography. MRA was performed at 1.5 T (USA study) or 3 T (Republic of Korea study). The primary criterion used to evaluate efficacy was the degree to which the MRA examination agreed with X-ray angiography in assessing non-coronary arterial lesions. The performance of Gd-DOTA over TOF was assessed using a one-sided paired t-test. We also evaluated the specificity, sensitivity, image quality, examination duration and clinical safety of both MRA procedures. Results In total, 192 patients were enrolled and received Gd-DOTA. In the intent-to-treat population (n=162), within-patient accuracy was significantly greater for Gd-DOTA than for TOF (85.8±19.8% agreement between Gd-DOTA and X-ray angiography compared with 78.3±24.9% agreement between TOF and X-ray angiography; p=0.0001). The sensitivity, specificity, image quality and examination duration were also better for Gd-DOTA than for TOF. There were no serious drug-related adverse events. Conclusion We conclude that Gd-DOTA-enhanced MRA is a safe and accurate procedure for detecting arterial stenosis at both 1.5 T and 3 T. PMID:22167518

  17. Computational hemodynamics of an implanted coronary stent based on three-dimensional cine angiography reconstruction.

    PubMed

    Chen, Mounter C Y; Lu, Po-Chien; Chen, James S Y; Hwang, Ned H C

    2005-01-01

    Coronary stents are supportive wire meshes that keep narrow coronary arteries patent, reducing the risk of restenosis. Despite the common use of coronary stents, approximately 20-35% of them fail due to restenosis. Flow phenomena adjacent to the stent may contribute to restenosis. Three-dimensional computational fluid dynamics (CFD) and reconstruction based on biplane cine angiography were used to assess coronary geometry and volumetric blood flows. A patient-specific left anterior descending (LAD) artery was reconstructed from single-plane x-ray imaging. With corresponding electrocardiographic signals, images from the same time phase were selected from the angiograms for dynamic three-dimensional reconstruction. The resultant three-dimensional LAD artery at end-diastole was adopted for detailed analysis. Both the geometries and flow fields, based on a computational model from CAE software (ANSYS and CATIA) and full three-dimensional Navier-Stroke equations in the CFD-ACE+ software, respectively, changed dramatically after stent placement. Flow fields showed a complex three-dimensional spiral motion due to arterial tortuosity. The corresponding wall shear stresses, pressure gradient, and flow field all varied significantly after stent placement. Combined angiography and CFD techniques allow more detailed investigation of flow patterns in various segments. The implanted stent(s) may be quantitatively studied from the proposed hemodynamic modeling approach.

  18. Angle-independent measure of motion for image-based gating in 3D coronary angiography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lehmann, Glen C.; Holdsworth, David W.; Drangova, Maria

    2006-05-15

    The role of three-dimensional (3D) image guidance for interventional procedures and minimally invasive surgeries is increasing for the treatment of vascular disease. Currently, most interventional procedures are guided by two-dimensional x-ray angiography, but computed rotational angiography has the potential to provide 3D geometric information about the coronary arteries. The creation of 3D angiographic images of the coronary arteries requires synchronization of data acquisition with respect to the cardiac cycle, in order to minimize motion artifacts. This can be achieved by inferring the extent of motion from a patient's electrocardiogram (ECG) signal. However, a direct measurement of motion (from the 2Dmore » angiograms) has the potential to improve the 3D angiographic images by ensuring that only projections acquired during periods of minimal motion are included in the reconstruction. This paper presents an image-based metric for measuring the extent of motion in 2D x-ray angiographic images. Adaptive histogram equalization was applied to projection images to increase the sharpness of coronary arteries and the superior-inferior component of the weighted centroid (SIC) was measured. The SIC constitutes an image-based metric that can be used to track vessel motion, independent of apparent motion induced by the rotational acquisition. To evaluate the technique, six consecutive patients scheduled for routine coronary angiography procedures were studied. We compared the end of the SIC rest period ({rho}) to R-waves (R) detected in the patient's ECG and found a mean difference of 14{+-}80 ms. Two simultaneous angular positions were acquired and {rho} was detected for each position. There was no statistically significant difference (P=0.79) between {rho} in the two simultaneously acquired angular positions. Thus we have shown the SIC to be independent of view angle, which is critical for rotational angiography. A preliminary image-based gating strategy that employed

  19. Utilization of cardiac computed tomography angiography and outpatient invasive coronary angiography in Ontario, Canada.

    PubMed

    Roifman, Idan; Rezai, Mohammad R; Wijeysundera, Harindra C; Chow, Benjamin J W; Wright, Graham A; Tu, Jack V

    2015-01-01

    Cardiac computed tomography angiography (coronary CTA) has emerged as a non-invasive method of diagnosing coronary artery disease. The extent of utilization and uptake of this technology since initiation of its funding by the government of Ontario is unknown. The aim of our study was to examine coronary CTA utilization and the rates of elective invasive coronary angiography and revascularization before and after funding initiation. We studied all coronary CTAs performed on adults in Ontario after initiation of funding. We also used an interrupted time series analysis to compare the average monthly rates of invasive angiography and revascularization before and after initiation of funding. There was an initial steep increase in age-and sex-standardized rates of coronary CTA from 5.0 to 11.4/100,000 over the first two quarters after funding initiation. Afterwards, there was a gradual increase in utilization from 11.4 to 17.1/100,000 over two subsequent calendar years. There was a significant reduction in both the mean monthly outpatient invasive coronary angiography (from 20.7 to 19.9 per 100,000 (p = 0.0004)) and revascularization (from 4.9 to 4.4 per 100,000 (p < 0.0001)) rates in the three years following introduction of the coronary CTA billing code as compared to the three prior to its introduction. Since the introduction of coronary CTA funding in Ontario, there has been a steady and controlled increase in its utilization. The increasing use of coronary CTA was associated with a reduction in both the rates of invasive angiography and revascularization. Copyright © 2015 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

  20. Individual selection of X-ray tube settings in computed tomography coronary angiography: Reliability of an automated software algorithm to maintain constant image quality.

    PubMed

    Durmus, Tahir; Luhur, Reny; Daqqaq, Tareef; Schwenke, Carsten; Knobloch, Gesine; Huppertz, Alexander; Hamm, Bernd; Lembcke, Alexander

    2016-05-01

    To evaluate a software tool that claims to maintain a constant contrast-to-noise ratio (CNR) in high-pitch dual-source computed tomography coronary angiography (CTCA) by automatically selecting both X-ray tube voltage and current. A total of 302 patients (171 males; age 61±12years; body weight 82±17kg, body mass index 27.3±4.6kg/cm(2)) underwent CTCA with a topogram-based, automatic selection of both tube voltage and current using dedicated software with quality reference values of 100kV and 250mAs/rotation (i.e., standard values for an average adult weighing 75kg) and an injected iodine load of 222mg/kg. The average radiation dose was estimated to be 1.02±0.64mSv. All data sets had adequate contrast enhancement. Average CNR in the aortic root, left ventricle, and left and right coronary artery was 15.7±4.5, 8.3±2.9, 16.1±4.3 and 15.3±3.9 respectively. Individual CNR values were independent of patients' body size and radiation dose. However, individual CNR values may vary considerably between subjects as reflected by interquartile ranges of 12.6-18.6, 6.2-9.9, 12.8-18.9 and 12.5-17.9 respectively. Moreover, average CNR values were significantly lower in males than females (15.1±4.1 vs. 16.6±11.7 and 7.9±2.7 vs. 8.9±3.0, 15.5±3.9 vs. 16.9±4.6 and 14.7±3.6 vs. 16.0±4.1 respectively). A topogram-based automatic selection of X-ray tube settings in CTCA provides diagnostic image quality independent of patients' body size. Nevertheless, considerable variation of individual CNR values between patients and significant differences of CNR values between males and females occur which questions the reliability of this approach. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  1. Additive value of 3T cardiovascular magnetic resonance coronary angiography for detecting coronary artery disease.

    PubMed

    Zhang, Lijun; Song, Xiantao; Dong, Li; Li, Jianan; Dou, Ruiyu; Fan, Zhanming; An, Jing; Li, Debiao

    2018-04-30

    The purpose of the work was to evaluate the incremental diagnostic value of free-breathing, contrast-enhanced, whole-heart, 3 T cardiovascular magnetic resonance coronary angiography (CE-MRCA) to stress/rest myocardial perfusion imaging (MPI) and late gadolinium enhancement (LGE) imaging for detecting coronary artery disease (CAD). Fifty-one patients with suspected CAD underwent a comprehensive cardiovascular magnetic resonance (CMR) examination (CE-MRCA, MPI, and LGE). The additive diagnostic value of MRCA to MPI and LGE was evaluated using invasive x-ray coronary angiography (XA) as the standard for defining functionally significant CAD (≥ 50% stenosis in vessels > 2 mm in diameter). 90.2% (46/51) patients (54.0 ± 11.5 years; 71.7% men) completed CE-MRCA successfully. On per-patient basis, compared to MPI/LGE alone or MPI alone, the addition of MRCA resulted in higher sensitivity (100% vs. 76.5%, p < 0.01), no change in specificity (58.3% vs. 66.7%, p = 0.6), and higher accuracy (89.1% vs 73.9%, p < 0.01) for CAD detection (prevalence = 73.9%). Compared to LGE alone, the addition of CE-MRCA resulted in higher sensitivity (97.1% vs. 41.2%, p < 0.01), inferior specificity (83.3% vs. 91.7%, p = 0.02), and higher diagnostic accuracy (93.5% vs. 54.3%, p < 0.01). The inclusion of successful free-breathing, whole-heart, 3 T CE-MRCA significantly improved the sensitivity and diagnostic accuracy as compared to MPI and LGE alone for CAD detection.

  2. Coronary angiography in worsening heart failure: determinants, findings and prognostic implications.

    PubMed

    Ferreira, João Pedro; Rossignol, Patrick; Demissei, Biniyam; Sharma, Abhinav; Girerd, Nicolas; Anker, Stefan D; Cleland, John G; Dickstein, Kenneth; Filippatos, Gerasimos; Hillege, Hans L; Lang, Chim C; Metra, Marco; Ng, Leong L; Ponikowski, Piotr; Samani, Nilesh J; van Veldhuisen, Dirk J; Zwinderman, Aeilko H; Voors, Adriaan; Zannad, Faiez

    2018-04-01

    Coronary angiography is regularly performed in patients with worsening signs and/or symptoms of heart failure (HF). However, little is known on the determinants, findings and associated clinical outcomes of coronary angiography performed in patients with worsening HF. The BIOSTAT-CHF (a systems BIOlogy Study to TAilored Treatment in Chronic Heart Failure) programme enrolled 2516 patients with worsening symptoms and/or signs of HF, either hospitalised or in the outpatient setting. All patients were included in the present analysis. Of the 2516 patients included, 315 (12.5%) underwent coronary angiography within the 30 days after the onset of worsening symptoms and/or signs of HF. Subjects who underwent angiography were more often observed as inpatients, had more often an overt acute coronary syndrome, had higher troponin I levels, were younger and had better renal function (all p≤0.01). Patients who underwent coronary angiography had a lower risk of the primary outcome of death and/or HF hospitalisation (adjusted HR=0.71, 95% CI 0.57 to 0.89, p=0.003) and death (adjusted HR=0.59, 95% CI 0.43 to 0.80, p=0.001). Among the patients who underwent coronary angiography, those with a coronary stenosis (39%) had a worse prognosis than those without stenosis (adjusted HR for the primary outcome=1.71, 95% CI 1.10 to 2.64, p=0.016). Coronary angiography was performed in <13% of patients with symptoms and/or signs of worsening HF. These patients were remarkably different from those who did not undergo coronary angiography and had a lower risk of subsequent events. The presence of coronary stenosis on coronary angiography was associated with a worse prognosis. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  3. Transient cortical blindness after coronary angiography.

    PubMed Central

    Parry, R; Rees, J R; Wilde, P

    1993-01-01

    Transient visual loss lasting three days developed after transfemoral coronary angiography in a 62 year old man. Computed tomography (CT) showed bilateral leakage of contrast medium into the occipital cortex. A repeat CT scan after his sight recovered showed clearance of contrast with no underlying infarction. A breakdown of the blood-brain barrier with direct neurotoxicity of the contrast media seemed to be the cause of these neurological changes after coronary angiography which apparently have not been reported before. Images PMID:8280526

  4. The evaluation of a formalized queue management system for coronary angiography waiting lists.

    PubMed

    Alter, D A; Newman, Alice M; Cohen, Eric A; Sykora, Kathy; Tu, Jack V

    2005-11-01

    Lengthy waiting lists for coronary angiography have been described in many health care systems worldwide. The extent to which formal queue management systems may improve the prioritization and survival of patients in the angiography queue is unknown. To prospectively evaluate the performance of a formal queue management system for patients awaiting coronary angiography in Ontario. The coronary angiography urgency scale, a formal queue management system developed in 1993 using a modified Delphi panel, allocates recommended maximum waiting times (RMWTs) in accordance with clinical necessity. By using a provincial clinical registry, 35,617 consecutive patients referred into the coronary angiography queue between April 1, 2001, and March 31, 2002, were prospectively tracked. Cox proportional hazards models were used to examined mortality risk across urgency after adjusting for additional clinical and comorbid factors. Good agreement was determined in urgency ratings between scores from the coronary angiography urgency scale and implicit physician judgement, which was obtained independently at the time of the index referral (weighted kappa = 0.49). The overall mortality in the queue was 0.3% (0.47%, 0.26% and 0.13% for urgent, semiurgent and elective patients, respectively). Urgency, as specified by the coronary angiography urgency scale, was the strongest predictor of death in the queue (P<0.001). However, when patients were censored according to their RMWTs, mortality was similar across different levels of urgency. Consequently, up to 18.5 deaths per 10,000 patients could have potentially been averted had patients been triaged and undergone coronary angiography within the RMWT as specified by the coronary angiography urgency scale. The incorporation of the coronary angiography urgency scale as a formal queue management system may decrease mortality in the coronary angiography queue. The authors recommend its implementation in health care systems where patients

  5. Stabilized display of coronary x-ray image sequences

    NASA Astrophysics Data System (ADS)

    Close, Robert A.; Whiting, James S.; Da, Xiaolin; Eigler, Neal L.

    2004-05-01

    Display stabilization is a technique by which a feature of interest in a cine image sequence is tracked and then shifted to remain approximately stationary on the display device. Prior simulations indicate that display stabilization with high playback rates ( 30 f/s) can significantly improve detectability of low-contrast features in coronary angiograms. Display stabilization may also help to improve the accuracy of intra-coronary device placement. We validated our automated tracking algorithm by comparing the inter-frame difference (jitter) between manual and automated tracking of 150 coronary x-ray image sequences acquired on a digital cardiovascular X-ray imaging system with CsI/a-Si flat panel detector. We find that the median (50%) inter-frame jitter between manual and automatic tracking is 1.41 pixels or less, indicating a jump no further than an adjacent pixel. This small jitter implies that automated tracking and manual tracking should yield similar improvements in the performance of most visual tasks. We hypothesize that cardiologists would perceive a benefit in viewing the stabilized display as an addition to the standard playback of cine recordings. A benefit of display stabilization was identified in 87 of 101 sequences (86%). The most common tasks cited were evaluation of stenosis and determination of stent and balloon positions. We conclude that display stabilization offers perceptible improvements in the performance of visual tasks by cardiologists.

  6. Coronary angiography using synchrotron radiation (invited)

    NASA Astrophysics Data System (ADS)

    Thompson, A. C.; Rubenstein, E.; Zeman, H. D.; Hofstadter, R.; Otis, J. N.; Giacomini, J. C.; Gordon, H. J.; Brown, G. S.; Thomlinson, W.; Kernoff, R. S.

    1989-07-01

    Imaging of coronary arteries using a venous instead of an arterial injection of contrast agent could provide a much safer method to diagnose heart disease. The tunability, intensity, and collimation of synchrotron radiation x-ray beams makes possible imaging systems with greatly improved imaging sensitivity. A pair of fan x-ray beams, a movable patient chair, and a multielement x-ray detector are used to acquire a pair of x-ray images above and below the iodine K edge. The logarithmic subtraction of these two images produces an image with excellent sensitivity to contrast agent and minimal sensitivity to bone and tissue. High-quality images from a dog and preliminary images from five humans have been obtained. Improvements are being made to the system to increase the effective radiation flux and to measure the position of both x-ray beams.

  7. Effectiveness of atrial fibrillation as an independent predictor of death and coronary events in patients having coronary angiography.

    PubMed

    Marte, Thomas; Saely, Christoph H; Schmid, Fabian; Koch, Lorena; Drexel, Heinz

    2009-01-01

    The impact of atrial fibrillation (AF) on future coronary events is uncertain. In particular, the prognostic impact of AF in the clinically important population of coronary patients who undergo angiography is unknown. The aim of this study was to investigate (1) the prevalence of AF, (2) its association with coronary atherosclerosis, and (3) its impact on future coronary events in patients who undergo angiography. Electrocardiograms were evaluated in a consecutive series of 613 patients who underwent coronary angiography. Prospectively, death and cardiovascular events were recorded over 4.0 +/- 0.6 years. Among these patients, 37 (6%) at baseline had AF, and 576 (94%) were in sinus rhythm. The presence of AF was associated with a lower prevalence of coronary artery disease and of coronary diameter narrowing >or=50% on baseline angiography. However, prospectively, patients with AF were at a strongly increased risk for all-cause mortality (adjusted hazard ratio 5.15, 95% confidence interval 2.36 to 11.26, p <0.001), coronary death (hazard ratio 8.16, 95% confidence interval 2.89 to 23.09, p <0.001), and major coronary events (hazard ratio 3.80, 95% confidence interval 1.45 to 9.94, p = 0.007). In conclusion, although inversely associated with the presence of angiographically determined coronary atherosclerosis, AF is a strong predictor of death and future coronary events in patients with coronary artery disease who undergo coronary angiography.

  8. Severity of coronary artery disease in obese patients undergoing coronary angiography: "obesity paradox" revisited.

    PubMed

    Niraj, Ashutosh; Pradhan, Jyotiranjan; Pradahan, Jyotiranjan; Fakhry, Hesham; Veeranna, Vikas; Afonso, Luis

    2007-08-01

    Recent studies have highlighted the existence of an 'obesity paradox' in patients undergoing coronary angiography, i.e., a high body mass Index (BMI) is associated with less severe coronary lesions. We sought to confirm the existence of this phenomenon in the US patient population. Study subjects included 770 consecutive patients (470 men, 428 African-Americans, 212 Caucasians) referred for coronary angiography to a tertiary care center. Duke myocardial jeopardy score, a prognostication tool predictive of 1-year mortality in coronary artery disease (CAD) patients, was assigned to angiographic data. Patients were classified according to their BMI (kg/m2) as normal (21-24), overweight (25-29), obesity class I (30-34), class II (35-39) and class III (40 or above). Patients in the increasing obesity class had a higher prevalence of diabetes, hypertension and dyslipidemia and were more likely to be women. A negative correlation was observed between BMI and age (R = - 0.15 p < 0.001) as well as between BMI and Duke Jeopardy score (r = - 0.07, p < 0.05) indicating that patients with higher BMI were referred for coronary angiography at a younger age, and had a lower coronary artery disease (CAD) burden. BMI was not an independent predictor of coronary lesion severity on multivariate stepwise linear regression analysis. Obese patients are referred for coronary angiography at an earlier age and have a lower CAD burden lending further credence to the existence of an apparent "obesity paradox". However, obesity per se, after adjustment for comorbidities, is not an independent predictor of severity of coronary artery disease. (c) 2007 Wiley Periodicals, Inc.

  9. Contrast Enhancement of the Right Ventricle during Coronary CT Angiography--Is It Necessary?

    PubMed

    Kok, Madeleine; Kietselaer, Bas L J H; Mihl, Casper; Altintas, Sibel; Nijssen, Estelle C; Wildberger, Joachim E; Das, Marco

    2015-01-01

    It is unclear if prolonged contrast media injection, to improve right ventricular visualization during coronary CT angiography, leads to increased detection of right ventricle pathology. The purpose of this study was to evaluate right ventricle enhancement and subsequent detection of right ventricle disease during coronary CT angiography. 472 consecutive patients referred for screening coronary CT angiography were retrospectively evaluated. Every patient underwent multidetector-row CT of the coronary arteries: 128x 0.6mm coll., 100-120kV, rot. time 0.28s, ref. mAs 350 and received an individualized (P3T) contrast bolus injection of iodinated contrast medium (300 mgI/ml). Patient data were analyzed to assess right ventricle enhancement (HU) and right ventricle pathology. Image quality was defined good when right ventricle enhancement >200HU, moderate when 140-200HU and poor when <140HU. Good image quality was found in 372 patients, moderate in 80 patients and poor in 20 patients. Mean enhancement of the right ventricle cavity was 268HU±102. Patients received an average bolus of 108±24 ml at an average peak flow rate of 6.1±2.2 ml/s. In only three out of 472 patients (0.63%) pathology of the right ventricle was found (dilatation) No other right ventricle pathology was detected. Right ventricle pathology was detected in three out of 472 patients; the dilatation observed in these three cases may have been picked up even without dedicated enhancement of the right ventricle. Based on our findings, right ventricle enhancement can be omitted during screening coronary CT angiography.

  10. CO2 microbubble contrast enhancement in x-ray angiography.

    PubMed

    Kariya, S; Komemushi, A; Nakatani, M; Yoshida, R; Sawada, S; Tanigawa, N

    2013-04-01

    To demonstrate that carbon dioxide (CO2) microbubble contrast enhancement depicts blood vessels when used for x-ray examinations. Microbubbles were generated by cavitation of physiological saline to which CO2 gas had been added using an ejector-type microbubble generator. The input pressure values for CO2 gas and physiological saline that produced a large quantity of CO2 microbubbles were obtained in a phantom. In an animal study, angiography was performed in three swine using three types of contrast: CO2 microbubbles, conventional CO2 gas, and iodinated contrast medium. For CO2 microbubble contrast enhancement, physiological saline, and CO2 gas were supplied at the input pressures calculated in the phantom experiment. Regions of interest were set in the abdominal aorta, external iliac arteries, and background. The difference in digital values between each artery and the background was calculated. The input pressures obtained in the phantom experiment were 0.16 MPa for physiological saline and 0.5 MPa for CO2 gas, with physiological saline input volume being 8.1 ml/s. Three interventional radiologists all evaluated the depictions of all arteries as "present" in the CO2 microbubble contrast enhancement, conventional CO2 contrast enhancement, and iodinated contrast enhancement performed in three swine. Digital values for all vessels with microbubble CO2 contrast enhancement were higher than background values. In x-ray angiography, blood vessels can be depicted by CO2 microbubble contrast enhancement, in which a large quantity of CO2 microbubbles is generated within blood vessels. Copyright © 2012 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  11. Usefulness of high-speed rotational coronary venous angiography during cardiac resynchronization therapy.

    PubMed

    Blendea, Dan; Mansour, Moussa; Shah, Ravi V; Chung, Jeffrey; Nandigam, Veena; Heist, E Kevin; Mela, Theofanie; Reddy, Vivek Y; Manzke, Robert; McPherson, Craig A; Ruskin, Jeremy N; Singh, Jagmeet P

    2007-11-15

    Standard coronary venous angiography (SCVA) provides a static, fixed projection of the coronary venous (CV) tree. High-speed rotational coronary venous angiography (RCVA) is a novel method of mapping CV anatomy using dynamic, multiangle visualization. The purpose of this study was to assess the value of RCVA during cardiac resynchronization therapy. Digitally acquired rotational CV angiograms from 49 patients (mean age 69 +/- 11 years) who underwent left ventricular lead implantation were analyzed. RCVA, which uses rapid isocentric rotation over a 110 degrees arc, acquiring 120 frames/angiogram, was compared with SCVA, defined as 2 static orthogonal views: right anterior oblique 45 degrees and left anterior oblique 45 degrees . RCVA demonstrated that the posterior vein-to-coronary sinus (CS) angle and the left marginal vein-to-CS angle were misclassified in 5 and 11 patients, respectively, using SCVA. RCVA identified a greater number of second-order tributaries with diameters >1.5 mm than SCVA. The CV branch selected for lead placement was initially identified in 100% of patients using RCVA but in only 74% of patients using SCVA. RCVA showed that the best angiographic view for visualizing the CS and its tributaries differed significantly among different areas of the CV tree and among patients. The area of the CV tree that showed less variability was the CS ostium, which had a fairly constant relation with the spine in shallow right anterior oblique and left anterior oblique projections. In conclusion, RCVA provided a more precise map of CV anatomy and the spatial relation of venous branches. It allowed the identification of fluoroscopic views that could facilitate cannulation of the CS. The final x-ray view displaying the appropriate CV branch for left ventricular lead implantation was often different from the conventional left anterior oblique and right anterior oblique views. RCVA identified the target branch for lead implantation more often than SCVA.

  12. Use of Coronary Computed Tomographic Angiography to Guide Management of Patients With Coronary Disease

    PubMed Central

    Williams, Michelle C.; Hunter, Amanda; Shah, Anoop S.V.; Assi, Valentina; Lewis, Stephanie; Smith, Joel; Berry, Colin; Boon, Nicholas A.; Clark, Elizabeth; Flather, Marcus; Forbes, John; McLean, Scott; Roditi, Giles; van Beek, Edwin J.R.; Timmis, Adam D.; Newby, David E.

    2016-01-01

    Background In a prospective, multicenter, randomized controlled trial, 4,146 patients were randomized to receive standard care or standard care plus coronary computed tomography angiography (CCTA). Objectives The purpose of this study was to explore the consequences of CCTA-assisted diagnosis on invasive coronary angiography, preventive treatments, and clinical outcomes. Methods In post hoc analyses, we assessed changes in invasive coronary angiography, preventive treatments, and clinical outcomes using national electronic health records. Results Despite similar overall rates (409 vs. 401; p = 0.451), invasive angiography was less likely to demonstrate normal coronary arteries (20 vs. 56; hazard ratios [HRs]: 0.39 [95% confidence interval (CI): 0.23 to 0.68]; p < 0.001) but more likely to show obstructive coronary artery disease (283 vs. 230; HR: 1.29 [95% CI: 1.08 to 1.55]; p = 0.005) in those allocated to CCTA. More preventive therapies (283 vs. 74; HR: 4.03 [95% CI: 3.12 to 5.20]; p < 0.001) were initiated after CCTA, with each drug commencing at a median of 48 to 52 days after clinic attendance. From the median time for preventive therapy initiation (50 days), fatal and nonfatal myocardial infarction was halved in patients allocated to CCTA compared with those assigned to standard care (17 vs. 34; HR: 0.50 [95% CI: 0.28 to 0.88]; p = 0.020). Cumulative 6-month costs were slightly higher with CCTA: difference $462 (95% CI: $303 to $621). Conclusions In patients with suspected angina due to coronary heart disease, CCTA leads to more appropriate use of invasive angiography and alterations in preventive therapies that were associated with a halving of fatal and non-fatal myocardial infarction. (Scottish COmputed Tomography of the HEART Trial [SCOT-HEART]; NCT01149590) PMID:27081014

  13. Detection and quantification of coronary calcium from dual energy chest x-rays: Phantom feasibility study.

    PubMed

    Zhou, Bo; Wen, Di; Nye, Katelyn; Gilkeson, Robert C; Eck, Brendan; Jordan, David; Wilson, David L

    2017-10-01

    We have demonstrated the ability to identify coronary calcium, a reliable biomarker of coronary artery disease, using nongated, 2-shot, dual energy (DE) chest x-ray imaging. Here we will use digital simulations, backed up by measurements, to characterize DE calcium signals and the role of potential confounds such as beam hardening, x-ray scatter, cardiac motion, and pulmonary artery pulsation. For the DE calcium signal, we will consider quantification, as compared to CT calcium score, and visualization. We created stylized and anatomical digital 3D phantoms including heart, lung, coronary calcium, spine, ribs, pulmonary artery, and adipose. We simulated high and low kVp x-ray acquisitions with x-ray spectra, energy dependent attenuation, scatter, ideal detector, and automatic exposure control (AEC). Phantoms allowed us to vary adipose thickness, cardiac motion, etc. We used specialized dual energy coronary calcium (DECC) processing that includes corrections for scatter and beam hardening. Beam hardening over a wide range of adipose thickness (0-30 cm) reduced the change in intensity of a coronary artery calcification (ΔI CAC ) by < 3% in DECC images. Scatter correction errors of ±50% affected the calcium signal (ΔI CAC ) in DECC images ±9%. If a simulated pulmonary artery fills with blood between exposures, it can give rise to a residual signal in DECC images, explaining pulmonary artery visibility in some clinical images. Residual misregistration can be mostly compensated by integrating signals in an enlarged region encompassing registration artifacts. DECC calcium score compared favorably to CT mass and volume scores over a number of phantom perturbations. Simulations indicate that proper DECC processing can faithfully recover coronary calcium signals. Beam hardening, errors in scatter estimation, cardiac motion, calcium residual misregistration etc., are all manageable. Simulations are valuable as we continue to optimize DE coronary calcium image processing

  14. Real-time colour pictorial radiation monitoring during coronary angiography: effect on patient peak skin and total dose during coronary angiography.

    PubMed

    Wilson, Sharon M; Prasan, Ananth M; Virdi, Amy; Lassere, Marissa; Ison, Glenn; Ramsay, David R; Weaver, James C

    2016-10-10

    The aim of this study was to evaluate whether a real-time (RT) colour pictorial radiation dose monitoring system reduces patient skin and total radiation dose during coronary angiography and intervention. Patient demographics, procedural variables and radiation parameters were recorded before and after institution of the RT skin dose recording system. Peak skin dose as well as traditionally available measures of procedural radiation dose were compared. A total of 1,077 consecutive patients underwent coronary angiography, of whom 460 also had PCI. Institution of the RT skin dose recording system resulted in a 22% reduction in peak skin dose after accounting for confounding variables. Radiation dose reduction was most pronounced in those having PCI but was also seen over a range of subgroups including those with prior coronary artery bypass surgery, high BMI, and with radial arterial access. This was associated with a significant reduction in the number of patients placed at risk of skin damage. Similar reductions in parameters reflective of total radiation dose were also demonstrated after institution of RT radiation monitoring. Institution of an RT skin dose recording reduced patient peak skin and total radiation dose during coronary angiography and intervention. Consideration should be given to widespread adoption of this technology.

  15. Prevalence of Hepatitis C Virus Seropositivity and Its Impact on Coronary Artery Disease among Egyptian Patients Referred for Coronary Angiography

    PubMed Central

    Salam, Ragab Abd El; Nabil, Baher; Saber, Marawan; AbdelWahab, Hany A.

    2016-01-01

    Background. We tested the prevalence and impact of HCV seropositivity among Egyptian patients referred for coronary angiography. Subjects and Methods. This cross-sectional study was conducted in Zagazig University hospitals including 509 patients scheduled for elective coronary angiography between June 2013 and June 2014. By taking full history on admission, laboratory workup including HCV Ab, echocardiography study, and coronary angiography, we calculated the mean number of coronary artery lesions and the mean number of affected coronary artery vessels for all patients. The severity of the coronary lesions was estimated using the Gensini score. Results. HCV seropositive patients referred for coronary angiography were about 30.3% (which is greater than the prevalence of HCV seropositivity among general population in Egypt), patients proved to have CAD who are HCV antibody positive had more severe coronary lesions than in seronegative one (p < 0.05), and patients proved to have CAD who are HCV antibody positive had comparable prevalence of cardiovascular risk factors as seronegative patients except for diabetes and hypertension which are more prevalent in seronegative patients (p < 0.05). Conclusion. Prevalence of HCV antibody positive patients referred for coronary angiography was about 30.3%, and CAD patients who are HCV antibody positive had more severe coronary lesions and less prevalence of diabetes and hypertension than HCV antibody negative. PMID:27882261

  16. [Comparison of 64 MDCT coronary CTA and coronary angiography in the detection of coronary artery stenosis in low risk patients with stable angina and acute coronary syndrome].

    PubMed

    Cazalas, G; Sarran, A; Amabile, N; Chaumoitre, K; Marciano-Chagnaud, S; Jacquier, A; Paganelli, F; Panuel, M

    2009-09-01

    To determine the accuracy of 64 MDCT coronary CTA (CCTA) compared to coronary angiography in low risk patients with stable angina and acute coronary syndrome and determine the number of significant coronary artery stenoses ( 50%) in these patients. Materials and methods. Fifty-five patients underwent CCTA using a 32 MDCT unit with z flying focus allowing the acquisition of 64 slices of 0.6 mm thickness as well as coronary angiography (gold standard). Nine patients were excluded due to prior coronary artery bypass surgery (n=4), insufficient breath hold (n=3), calcium scoring>1000 (n=1) and delay between both examinations over 4 months (n=1). Forty-six patients: 27 males and 19 females were included. CCTA results were compared to coronary angiography per segment and artery with threshold detection of stenoses 50%. The degree of correlation between both examinations was performed using a regression analysis with a Pearson correlation coefficient<0.05 considered significant. The overall accuracy of CCTA was 90%; limitations related to the presence of calcifications, motion artifacts or insufficient vessel opacification. The correlation for all analyzed segments was 96.4%. Thirty-eight of 50 significant stenoses seen on coronary angiography were correctly detected on CCTA. Sensitivity, specificity, PPVC and NPV for detection of stenoses 50% were 76%, 98.3%, 80.3% and 97.7% respectively. Evaluation per segment had a NPV of 96.8% (interventricular and diagonal segments) to 100% (main trunk). Our results for specificity and NPV are similar to reports from the literature. This suggests that CCTA in this clinical setting may replace coronary angiography.

  17. Value of Image Fusion in Coronary Angiography for the Detection of Coronary Artery Bypass Grafts.

    PubMed

    Plessis, Julien; Warin Fresse, Karine; Cahouch, Zachary; Manigold, Thibaut; Letocart, Vincent; Le Gloan, Laurianne; Guyomarch, Béatrice; Guerin, Patrice

    2016-06-10

    Coronary angiography is more complex in patients with coronary artery bypass grafts (CABG). Image fusion is a new technology that allows the overlay of a computed tomography (CT) three-dimension (3D) model with fluoroscopic images in real time. This single-center prospective study included 66 previous CABG patients undergoing coronary and bypass graft angiography. Image fusion coronary angiographies (fusion group, 20 patients) were compared to conventional coronary angiographies (control group, 46 patients). The fusion group included patients for whom a previous chest CT scan with contrast was available. For patients in this group, aorta and CABG were reconstructed in 3D from CT acquisitions and merged in real time with fluoroscopic images. The following parameters were compared: time needed to localize the CABG; procedure duration; air kerma (AK); dose area product (DAP); and volume of contrast media injected. Results are expressed as median. There were no significant differences between the 2 groups in patient demographics and procedure characteristics (access site, number of bypass to be found, and interventional cardiologist's experience). The time to localize CABG was significantly shorter in the fusion group (7.3 versus 12.4 minutes; P=0.002), as well as the procedure duration (20.6 versus 25.6 minutes; P=0.002), AK (610 versus 814 mGy; P=0.02), DAP (4390 versus 5922.5 cGy·cm(2); P=0.02), and volume of iodinated contrast media (85 versus 116 cc; P=0.002). 3D image fusion improves the CABG detection in coronary angiography and reduces the time necessary to localize CABG, total procedure time duration, radiation exposure, and volume of contrast media. © 2016 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  18. Coronary microvascular dysfunction equivalent to left main coronary artery disease.

    PubMed

    Panç, Cafer; Kocaağa, Mehmet; Erdoğan, Onur; Sarıkaya, Remzi; Umman, Sabahattin

    2017-04-01

    Coronary microvascular dysfunction, also known as cardiac syndrome X, is a clinical syndrome presenting with typical angina and evidence of myocardial ischemia in the absence of flow-limiting stenosis on coronary angiography. Of patients undergoing coronary angiography due to suspected myocardial ischemia, 50% are found to have normal or near-normal coronary arteries. Described in this case report is a patient who developed hypotension and ST segment depressions during treadmill exercise test. Left main coronary artery or multivessel disease was suspected. Coronary angiography was normal, but coronary flow reserve measurement revealed severe microvascular dysfunction.

  19. Coronary CT Angiography-derived Fractional Flow Reserve: Machine Learning Algorithm versus Computational Fluid Dynamics Modeling.

    PubMed

    Tesche, Christian; De Cecco, Carlo N; Baumann, Stefan; Renker, Matthias; McLaurin, Tindal W; Duguay, Taylor M; Bayer, Richard R; Steinberg, Daniel H; Grant, Katharine L; Canstein, Christian; Schwemmer, Chris; Schoebinger, Max; Itu, Lucian M; Rapaka, Saikiran; Sharma, Puneet; Schoepf, U Joseph

    2018-04-10

    Purpose To compare two technical approaches for determination of coronary computed tomography (CT) angiography-derived fractional flow reserve (FFR)-FFR derived from coronary CT angiography based on computational fluid dynamics (hereafter, FFR CFD ) and FFR derived from coronary CT angiography based on machine learning algorithm (hereafter, FFR ML )-against coronary CT angiography and quantitative coronary angiography (QCA). Materials and Methods A total of 85 patients (mean age, 62 years ± 11 [standard deviation]; 62% men) who had undergone coronary CT angiography followed by invasive FFR were included in this single-center retrospective study. FFR values were derived on-site from coronary CT angiography data sets by using both FFR CFD and FFR ML . The performance of both techniques for detecting lesion-specific ischemia was compared against visual stenosis grading at coronary CT angiography, QCA, and invasive FFR as the reference standard. Results On a per-lesion and per-patient level, FFR ML showed a sensitivity of 79% and 90% and a specificity of 94% and 95%, respectively, for detecting lesion-specific ischemia. Meanwhile, FFR CFD resulted in a sensitivity of 79% and 89% and a specificity of 93% and 93%, respectively, on a per-lesion and per-patient basis (P = .86 and P = .92). On a per-lesion level, the area under the receiver operating characteristics curve (AUC) of 0.89 for FFR ML and 0.89 for FFR CFD showed significantly higher discriminatory power for detecting lesion-specific ischemia compared with that of coronary CT angiography (AUC, 0.61) and QCA (AUC, 0.69) (all P < .0001). Also, on a per-patient level, FFR ML (AUC, 0.91) and FFR CFD (AUC, 0.91) performed significantly better than did coronary CT angiography (AUC, 0.65) and QCA (AUC, 0.68) (all P < .0001). Processing time for FFR ML was significantly shorter compared with that of FFR CFD (40.5 minutes ± 6.3 vs 43.4 minutes ± 7.1; P = .042). Conclusion The FFR ML algorithm performs equally in

  20. Sublingual Nitroglycerin Administration in Coronary Computed Tomography Angiography: a Systematic Review.

    PubMed

    Takx, Richard A P; Suchá, Dominika; Park, Jakob; Leiner, Tim; Hoffmann, Udo

    2015-12-01

    To systematically investigate the literature for the influence of sublingual nitroglycerin administration on coronary diameter, the number of evaluable segments, image quality, heart rate and blood pressure, and diagnostic accuracy of coronary computed tomography (CT) angiography. A systematic search was performed in PubMed, EMBASE and Web of Science. The studies were evaluated for the effect of sublingual nitroglycerin on coronary artery diameter, evaluable segments, objective and subjective image quality, systemic physiological effects and diagnostic accuracy. Due to the heterogeneous reporting of outcome measures, a narrative synthesis was applied. Of the 217 studies identified, nine met the inclusion criteria: seven reported on the effect of nitroglycerin on coronary artery diameter, six on evaluable segments, four on image quality, five on systemic physiological effects and two on diagnostic accuracy. Sublingual nitroglycerin administration resulted in an improved evaluation of more coronary segments, in particular, in smaller coronary branches, better image quality and improved diagnostic accuracy. Side effects were mild and were alleviated without medical intervention. Sublingual nitroglycerin improves the coronary diameter, the number of assessable segments, image quality and diagnostic accuracy of coronary CT angiography without major side effects or systemic physiological changes. • Sublingual nitroglycerin administration results in significant coronary artery dilatation. • Nitroglycerin increases the number of evaluable coronary branches. • Image quality is improved the most in smaller coronary branches. • Nitroglycerin increases the diagnostic accuracy of coronary CT angiography. • Most side effects are mild and do not require medical intervention.

  1. Systematic preoperative coronary angiography and stenting improves postoperative results of carotid endarterectomy in patients with asymptomatic coronary artery disease: a randomised controlled trial.

    PubMed

    Illuminati, G; Ricco, J-B; Greco, C; Mangieri, E; Calio', F; Ceccanei, G; Pacilè, M A; Schiariti, M; Tanzilli, G; Barillà, F; Paravati, V; Mazzesi, G; Miraldi, F; Tritapepe, L

    2010-02-01

    To evaluate the usefulness of systematic coronary angiography followed, if needed, by coronary artery angioplasty (percutaneous coronary intervention (PCI)) on the incidence of cardiac ischaemic events after carotid endarterectomy (CEA) in patients without evidence of coronary artery disease (CAD). From January 2005 to December 2008, 426 patients, candidates for CEA, with no history of CAD and with normal cardiac ultrasound and electrocardiography (ECG), were randomised into two groups. In group A (n=216) all the patients had coronary angiography performed before CEA. In group B, all the patients had CEA without previous coronary angiography. In group A, 66 patients presenting significant coronary artery lesions at angiography received PCI before CEA. They subsequently underwent surgery under aspirin (100 mg day(-1)) and clopidogrel (75 mg day(-1)). CEA was performed within a median delay of 4 days after PCI (range: 1-8 days). Risk factors, indications for CEA and surgical techniques were comparable in both groups (p>0.05). The primary combined endpoint of the study was the incidence of postoperative myocardial ischaemic events combined with the incidence of complications of coronary angiography. Secondary endpoints were death and stroke rates after CEA and incidence of cervical haematoma. Postoperative mortality was 0% in group A and 0.9% in group B (p=0.24). One postoperative stroke (0.5%) occurred in group A, and two (0.9%) in group B (p=0.62). No postoperative myocardial event was observed in group A, whereas nine ischaemic events were observed in group B, including one fatal myocardial infarction (p=0.01). Binary logistic regression analysis demonstrated that preoperative coronary angiography was the only independent variable that predicted the occurrence of postoperative coronary ischaemia after CEA. The odds ratio for coronary angiography (group A) indicated that when holding all other variables constant, a patient having preoperative coronary angiography

  2. Deformable known component model-based reconstruction for coronary CT angiography

    NASA Astrophysics Data System (ADS)

    Zhang, X.; Tilley, S.; Xu, S.; Mathews, A.; McVeigh, E. R.; Stayman, J. W.

    2017-03-01

    Purpose: Atherosclerosis detection remains challenging in coronary CT angiography for patients with cardiac implants. Pacing electrodes of a pacemaker or lead components of a defibrillator can create substantial blooming and streak artifacts in the heart region, severely hindering the visualization of a plaque of interest. We present a novel reconstruction method that incorporates a deformable model for metal leads to eliminate metal artifacts and improve anatomy visualization even near the boundary of the component. Methods: The proposed reconstruction method, referred as STF-dKCR, includes a novel parameterization of the component that integrates deformation, a 3D-2D preregistration process that estimates component shape and position, and a polyenergetic forward model for x-ray propagation through the component where the spectral properties are jointly estimated. The methodology was tested on physical data of a cardiac phantom acquired on a CBCT testbench. The phantom included a simulated vessel, a metal wire emulating a pacing lead, and a small Teflon sphere attached to the vessel wall, mimicking a calcified plaque. The proposed method was also compared to the traditional FBP reconstruction and an interpolation-based metal correction method (FBP-MAR). Results: Metal artifacts presented in standard FBP reconstruction were significantly reduced in both FBP-MAR and STF- dKCR, yet only the STF-dKCR approach significantly improved the visibility of the small Teflon target (within 2 mm of the metal wire). The attenuation of the Teflon bead improved to 0.0481 mm-1 with STF-dKCR from 0.0166 mm-1 with FBP and from 0.0301 mm-1 with FBP-MAR - much closer to the expected 0.0414 mm-1. Conclusion: The proposed method has the potential to improve plaque visualization in coronary CT angiography in the presence of wire-shaped metal components.

  3. Relationship of Hypertension to Coronary Atherosclerosis and Cardiac Events in Patients With Coronary Computed Tomographic Angiography.

    PubMed

    Nakanishi, Rine; Baskaran, Lohendran; Gransar, Heidi; Budoff, Matthew J; Achenbach, Stephan; Al-Mallah, Mouaz; Cademartiri, Filippo; Callister, Tracy Q; Chang, Hyuk-Jae; Chinnaiyan, Kavitha; Chow, Benjamin J W; DeLago, Augustin; Hadamitzky, Martin; Hausleiter, Joerg; Cury, Ricardo; Feuchtner, Gudrun; Kim, Yong-Jin; Leipsic, Jonathon; Kaufmann, Philipp A; Maffei, Erica; Raff, Gilbert; Shaw, Leslee J; Villines, Todd C; Dunning, Allison; Marques, Hugo; Pontone, Gianluca; Andreini, Daniele; Rubinshtein, Ronen; Bax, Jeroen; Jones, Erica; Hindoyan, Niree; Gomez, Millie; Lin, Fay Y; Min, James K; Berman, Daniel S

    2017-08-01

    Hypertension is an atherosclerosis factor and is associated with cardiovascular risk. We investigated the relationship between hypertension and the presence, extent, and severity of coronary atherosclerosis in coronary computed tomographic angiography and cardiac events risk. Of 17 181 patients enrolled in the CONFIRM registry (Coronary CT Angiography Evaluation for Clinical Outcomes: An International Multicenter Registry) who underwent ≥64-detector row coronary computed tomographic angiography, we identified 14 803 patients without known coronary artery disease. Of these, 1434 hypertensive patients were matched to 1434 patients without hypertension. Major adverse cardiac events risk of hypertension and non-hypertensive patients was evaluated with Cox proportional hazards models. The prognostic associations between hypertension and no-hypertension with increasing degree of coronary stenosis severity (nonobstructive or obstructive ≥50%) and extent of coronary artery disease (segment involvement score of 1-5, >5) was also assessed. Hypertension patients less commonly had no coronary atherosclerosis and more commonly had nonobstructive and 1-, 2-, and 3-vessel disease than the no-hypertension group. During a mean follow-up of 5.2±1.2 years, 180 patients experienced cardiac events, with 104 (2.0%) occurring in the hypertension group and 76 (1.5%) occurring in the no-hypertension group (hazard ratios, 1.4; 95% confidence intervals, 1.0-1.9). Compared with no-hypertension patients without coronary atherosclerosis, hypertension patients with no coronary atherosclerosis and obstructive coronary disease tended to have higher risk of cardiac events. Similar trends were observed with respect to extent of coronary artery disease. Compared with no-hypertension patients, hypertensive patients have increased presence, extent, and severity of coronary atherosclerosis and tend to have an increase in major adverse cardiac events. © 2017 American Heart Association, Inc.

  4. Noninvasive coronary artery angiography using electron beam computed tomography

    NASA Astrophysics Data System (ADS)

    Rumberger, John A.; Rensing, Benno J.; Reed, Judd E.; Ritman, Erik L.; Sheedy, Patrick F., II

    1996-04-01

    Electron beam computed tomography (EBCT), also known as ultrafast-CT or cine-CT, uses a unique scanning architecture which allows for multiple high spatial resolution electrocardiographic triggered images of the beating heart. A recent study has demonstrated the feasibility of qualitative comparisons between EBCT derived 3D coronary angiograms and invasive angiography. Stenoses of the proximal portions of the left anterior descending and right coronary arteries were readily identified, but description of atherosclerotic narrowing in the left circumflex artery (and distal epicardial disease) was not possible with any degree of confidence. Although these preliminary studies support the notion that this approach has potential, the images overall were suboptimal for clinical application as an adjunct to invasive angiography. Furthermore, these studies did not examine different methods of EBCT scan acquisition, tomographic slice thicknesses, extent of scan overlap, or other segmentation, thresholding, and interpolation algorithms. Our laboratory has initiated investigation of these aspects and limitations of EBCT coronary angiography. Specific areas of research include defining effects of cardiac orientation; defining the effects of tomographic slice thickness and intensity (gradient) versus positional (shaped based) interpolation; and defining applicability of imaging each of the major epicardial coronary arteries for quantitative definition of vessel size, cross-sectional area, taper, and discrete vessel narrowing.

  5. Coronary artery calcium scoring does not add prognostic value to standard 64-section CT angiography protocol in low-risk patients suspected of having coronary artery disease.

    PubMed

    Kwon, Sung Woo; Kim, Young Jin; Shim, Jaemin; Sung, Ji Min; Han, Mi Eun; Kang, Dong Won; Kim, Ji-Ye; Choi, Byoung Wook; Chang, Hyuk-Jae

    2011-04-01

    To evaluate the prognostic outcome of cardiac computed tomography (CT) for prediction of major adverse cardiac events (MACEs) in low-risk patients suspected of having coronary artery disease (CAD) and to explore the differential prognostic values of coronary artery calcium (CAC) scoring and coronary CT angiography. Institutional review committee approval and informed consent were obtained. In 4338 patients who underwent 64-section CT for evaluation of suspected CAD, both CAC scoring and CT angiography were concurrently performed by using standard scanning protocols. Follow-up clinical outcome data regarding composite MACEs were procured. Multivariable Cox proportional hazards models were developed to predict MACEs. Risk-adjusted models incorporated traditional risk factors for CAC scoring and coronary CT angiography. During the mean follow-up of 828 days ± 380, there were 105 MACEs, for an event rate of 3%. The presence of obstructive CAD at coronary CT angiography had independent prognostic value, which escalated according to the number of stenosed vessels (P < .001). In the receiver operating characteristic curve (ROC) analysis, the superiority of coronary CT angiography to CAC scoring was demonstrated by a significantly greater area under the ROC curve (AUC) (0.892 vs 0.810, P < .001), whereas no significant incremental value for the addition of CAC scoring to coronary CT angiography was established (AUC = 0.892 for coronary CT angiography alone vs 0.902 with addition of CAC scoring, P = .198). Coronary CT angiography is better than CAC scoring in predicting MACEs in low-risk patients suspected of having CAD. Furthermore, the current standard multisection CT protocol (coronary CT angiography combined with CAC scoring) has no incremental prognostic value compared with coronary CT angiography alone. Therefore, in terms of determining prognosis, CAC scoring may no longer need to be incorporated in the cardiac CT protocol in this population. © RSNA, 2011.

  6. Optimal timing of coronary angiography and potential intervention in non-ST-elevation acute coronary syndromes.

    PubMed

    Katritsis, Demosthenes G; Siontis, George C M; Kastrati, Adnan; van't Hof, Arnoud W J; Neumann, Franz-Josef; Siontis, Konstantinos C M; Ioannidis, John P A

    2011-01-01

    An invasive approach is superior to medical management for the treatment of patients with acute coronary syndromes without ST-segment elevation (NSTE-ACS), but the optimal timing of coronary angiography and subsequent intervention, if indicated, has not been settled. We conducted a meta-analysis of randomized trials addressing the optimal timing (early vs. delayed) of coronary angiography in NSTE-ACS. Four trials with 4013 patients were eligible (ABOARD, ELISA, ISAR-COOL, TIMACS), and data for longer follow-up periods than those published became available for this meta-analysis by the ELISA and ISAR-COOL investigators. The median time from admission or randomization to coronary angiography ranged from 1.16 to 14 h in the early and 20.8-86 h in the delayed strategy group. No statistically significant difference of risk of death [random effects risk ratio (RR) 0.85, 95% confidence interval (CI) 0.64-1.11] or myocardial infarction (MI) (RR 0.94, 95% CI 0.61-1.45) was detected between the two strategies. Early intervention significantly reduced the risk for recurrent ischaemia (RR 0.59, 95% CI 0.38-0.92, P = 0.02) and the duration of hospital stay (by 28%, 95% CI 22-35%, P < 0.001). Furthermore, decreased major bleeding events (RR 0.78, 95% CI 0.57-1.07, P = 0.13), and less major events (death, MI, or stroke) (RR 0.91, 95% CI 0.82-1.01, P = 0.09) were observed with the early strategy but these differences were not nominally significant. Early coronary angiography and potential intervention reduces the risk of recurrent ischaemia, and shortens hospital stay in patients with NSTE-ACS.

  7. Fusion of CTA and XA data using 3D centerline registration for plaque visualization during coronary intervention

    NASA Astrophysics Data System (ADS)

    Kaila, Gaurav; Kitslaar, Pieter; Tu, Shengxian; Penicka, Martin; Dijkstra, Jouke; Lelieveldt, Boudewijn

    2016-03-01

    Coronary Artery Disease (CAD) results in the buildup of plaque below the intima layer inside the vessel wall of the coronary arteries causing narrowing of the vessel and obstructing blood flow. Percutaneous coronary intervention (PCI) is usually done to enlarge the vessel lumen and regain back normal flow of blood to the heart. During PCI, X-ray imaging is done to assist guide wire movement through the vessels to the area of stenosis. While X-ray imaging allows for good lumen visualization, information on plaque type is unavailable. Also due to the projection nature of the X-ray imaging, additional drawbacks such as foreshortening and overlap of vessels limit the efficacy of the cardiac intervention. Reconstruction of 3D vessel geometry from biplane X-ray acquisitions helps to overcome some of these projection drawbacks. However, the plaque type information remains an issue. In contrast, imaging using computed tomography angiography (CTA) can provide us with information on both lumen and plaque type and allows us to generate a complete 3D coronary vessel tree unaffected by the foreshortening and overlap problems of the X-ray imaging. In this paper, we combine x-ray biplane images with CT angiography to visualize three plaque types (dense calcium, fibrous fatty and necrotic core) on x-ray images. 3D registration using three different registration methods is done between coronary centerlines available from x-ray images and from the CTA volume along with 3D plaque information available from CTA. We compare the different registration methods and evaluate their performance based on 3D root mean squared errors. Two methods are used to project this 3D information onto 2D plane of the x-ray biplane images. Validation of our approach is performed using artificial biplane x-ray datasets.

  8. Accuracy of MSCT Coronary Angiography with 64 Row CT Scanner—Facing the Facts

    PubMed Central

    Wehrschuetz, M.; Wehrschuetz, E.; Schuchlenz, H.; Schaffler, G.

    2010-01-01

    Improvements in multislice computed tomography (MSCT) angiography of the coronary vessels have enabled the minimally invasive detection of coronary artery stenoses, while quantitative coronary angiography (QCA) is the accepted reference standard for evaluation thereof. Sixteen-slice MSCT showed promising diagnostic accuracy in detecting coronary artery stenoses haemodynamically and the subsequent introduction of 64-slice scanners promised excellent and fast results for coronary artery studies. This prompted us to evaluate the diagnostic accuracy, sensitivity, specificity, and the negative und positive predictive value of 64-slice MSCT in the detection of haemodynamically significant coronary artery stenoses. Thirty-seven consecutive subjects with suspected coronary artery disease were evaluated with MSCT angiography and the results compared with QCA. All vessels were considered for the assessment of significant coronary artery stenosis (diameter reduction ≥ 50%). Thirteen patients (35%) were identified as having significant coronary artery stenoses on QCA with 6.3% (35/555) affected segments. None of the coronary segments were excluded from analysis. Overall sensitivity for classifying stenoses of 64-slice MSCT was 69%, specificity was 92%, positive predictive value was 38% and negative predictive value was 98%. The interobserver variability for detection of significant lesions had a k-value of 0.43. Sixty-four-slice MSCT offers the diagnostic potential to detect coronary artery disease, to quantify haemodynamically significant coronary artery stenoses and to avoid unnecessary invasive coronary artery examinations. PMID:20567636

  9. Monocyte Chemoattractant Protein-1 as a Predictor of Coronary Atherosclerosis in Patients Receiving Coronary Angiography.

    PubMed

    Mahler, Simon A; Register, Thomas C; Riley, Robert F; D'Agostino, Ralph B; Stopyra, Jason P; Miller, Chadwick D

    2018-06-01

    Animal studies suggest that monocyte chemoattractant protein-1 (MCP-1) is a promising biomarker for coronary artery atherosclerosis (CAA), but human studies have been inconclusive. To determine potential relationships between plasma MCP-1 and CAA in patients with acute chest pain. A secondary analysis of 150 patients enrolled in emergency department chest pain risk stratification clinical investigations was conducted. Participants with stored blood and known coronary phenotypes (determined by coronary angiography) were selected using stratified randomization such that 50 patients were included into 3 groups: (1) no angiographic evidence of CAA, (2) nonobstructive CAA, and (3) obstructive CAA (stenosis ≥ 70%). Plasma MCP-1 levels were determined by enzyme-linked immunosorbent assay. The association between MCP-1 and obstructive CAA or any CAA was modeled using logistic regression. Variables in the unreduced model included age, sex, race, prior diagnosis of CAA or acute coronary syndrome, hyperlipidemia, hypertension, diabetes, smoking, and cardiac troponin I measurement. Among the 150 participants, 65.3% (98/150) had invasive coronary angiography and 34.7% (52/150) had coronary computed tomographic angiography. Myocardial infarction occurred in 27.3% (41/150) and coronary revascularization occurred in 26% (39/150) of the participants. Each 10 pg/mL increase in MCP-1 measurement was associated with an odds ratio of 1.12 (95% confidence interval, 1.06-1.19) for obstructive CAA. MCP-1 remained a significant predictor of obstructive CAA and any CAA after adjustment for age, sex, race, traditional cardiac risk factors, and cardiac troponin I. MCP-1 is independently associated with CAA among emergency department patients with chest pain.

  10. Iodine filter imaging system for subtraction angiography using synchrotron radiation

    NASA Astrophysics Data System (ADS)

    Umetani, K.; Ueda, K.; Takeda, T.; Itai, Y.; Akisada, M.; Nakajima, T.

    1993-11-01

    A new type of real-time imaging system was developed for transvenous coronary angiography. A combination of an iodine filter and a single energy broad-bandwidth X-ray produces two-energy images for the iodine K-edge subtraction technique. X-ray images are sequentially converted to visible images by an X-ray image intensifier. By synchronizing the timing of the movement of the iodine filter into and out of the X-ray beam, two output images of the image intensifier are focused side by side on the photoconductive layer of a camera tube by an oscillating mirror. Both images are read out by electron beam scanning of a 1050-scanning-line video camera within a camera frame time of 66.7 ms. One hundred ninety two pairs of iodine-filtered and non-iodine-filtered images are stored in the frame memory at a rate of 15 pairs/s. In vivo subtracted images of coronary arteries in dogs were obtained in the form of motion pictures.

  11. Acceptance of Combined Coronary CT Angiography and Myocardial CT Perfusion versus Conventional Coronary Angiography in Patients with Coronary Stents—Intraindividual Comparison

    PubMed Central

    Martus, Peter; Laule, Michael; Dewey, Marc; Schönenberger, Eva

    2015-01-01

    Objectives To evaluate how well patients with coronary stents accept combined coronary computed tomography angiography (CTA) and myocardial CT perfusion (CTP) compared with conventional coronary angiography (CCA). Background While combined CTA and CTP may improve diagnostic accuracy compared with CTA alone, patient acceptance of CTA/CTP remains to be defined. Methods A total of 90 patients with coronary stents prospectively underwent CTA/CTP (both with contrast agent, CTP with adenosine) and CCA as part of the CARS-320 study. In this group, an intraindividual comparison of patient acceptance of CTA, CTP, and CCA was performed. Results CTP was experienced to be significantly more painful than CTA (p<0.001) and was associated with a higher frequency of dyspnea (p<0.001). Comparison of CTA/CTP with CCA revealed no significant differences in terms of pain (p = 0.141) and comfort (p = 0.377). Concern before CTA/CTP and CCA and overall satisfaction were likewise not significantly different (p = 0.097 and p = 0.123, respectively). Nevertheless, about two thirds (n = 60, 68%) preferred CTA/CTP to CCA (p<0.001). Moreover, patients felt less helpless during CTA/CTP than during CCA (p = 0.026). Lack of invasiveness and absence of pain were the most frequently mentioned advantages of CTA/CTP over CCA in our patient population. Conclusions CCA and combined CTA/CTP are equally well accepted by patients; however, more patients prefer CTA/CTP. CTP was associated with more intense pain than CTA and more frequently caused dyspnea than CTA alone. Trial Registration ClinicalTrials.gov NCT00967876 PMID:26327127

  12. The utility of postmortem computed tomography selective coronary angiography in parallel with autopsy.

    PubMed

    Inokuchi, Go; Yajima, Daisuke; Hayakawa, Mutsumi; Motomura, Ayumi; Chiba, Fumiko; Torimitsu, Suguru; Makino, Yohsuke; Iwase, Hirotaro

    2013-12-01

    Historically, coronary angiography of the isolated heart has played an important role in the detection of stenotic or occlusive lesions that are difficult to identify by autopsy alone. Meanwhile, although the application of multidetector computed tomography (MDCT) to forensic fields has accelerated recently, isolated single organ angiography with MDCT is rarely performed. In this article, we present an evaluation of postmortem selective coronary CT angiography of the isolated heart with MDCT and discuss its utility for autopsy. First, in a preliminary experiment using pig coronary artery, we examined the behavior of water soluble contrast material on postmortem computed tomography angiography (PMCTA) and found that better angiographic images were acquired when the viscosity of the contrast material was increased and CT was performed under conditions of sustained perfusion. Based on these results, we devised a selective coronary angiography procedure using a pressurized bag for drip infusion that can be performed easily, quickly, and at low cost. The angiographic images obtained provided useful supportive evidence of autopsy findings suggestive of ischemic heart disease. With active discussions underway in forensic fields on the proper use of postmortem computed tomography, PMCTA has also naturally attracted attention as it compensates for some of the shortcomings of CT alone. Although PMCTA typically involves whole-body angiography, if we view PMCTA as one of the many useful and supplementary tools available for autopsy, then isolated heart angiography continues to have utility in autopsy today.

  13. Prevalence of Atherosclerotic Coronary Stenosis in Asymptomatic North Indian Population: A Post-mortem Coronary Angiography Study.

    PubMed

    Bansal, Yogender Singh; Mandal, Shatrugan Prasad; Kumar, Senthil; Setia, Puneet

    2015-09-01

    A preliminary study of coronaries using post-mortem angiography was undertaken to see the prevalence of atherosclerotic coronary stenosis in non-cardiac unnatural deaths. This study was conducted in a tertiary care centre located in Chandigarh. A total of 128 medico-legal cases were studied comprising 88 males and 40 females. Post-mortem examinations of these MLC cases were conducted in the Department of Forensic Medicine, PGIMER, Chandigarh. All hearts were visually screened by post-mortem coronary angiography first and then grossly examined using serial transverse incision technique in positive screening cases to find the degree of narrowing. Of the study group, 34% males and 20% females showed evidence of narrowing on angiography. Of the males showing coronary stenosis, 83% had single vessel disease and 13% had double vessel disease, while only one individual had triple vessel disease. In cases of female, all the cases of coronary stenosis were single vessel disease. Left anterior descending coronary artery (LAD) was the most common vessel involved, followed by right coronary artery (RCA) & Left circumflex artery (LCX) and in cases of double vessel disease, LAD in combination with LCX was responsible for 75% of the cases. Remarkably 23.6% of study population in the age group of less than 40 years showed appreciable narrowing in at least one of the coronaries. In general, the prevalence of CAD is on the rise, particularly in younger population owing to the changes in their lifestyle and food habits. This preliminary study revealed evidence of narrowing of at least one coronary in 34% male and 20% female population and 23.6% subjects were less than 40 years old. Further detailed studies are needed especially in younger age group and to support the need for preventive cardiology in the early years of life.

  14. Efficacy of RADPAD protective drape during coronary angiography.

    PubMed

    Kherad, B; Jerichow, T; Blaschke, F; Noutsias, M; Pieske, B; Tschöpe, C; Krackhardt, F

    2018-06-01

    Ionizing radiation is an integral part of percutaneous coronary angiographies. Chronic exposure to low-dose radiation confers a risk for skin damage, eye lens opacities or cataracts, and malignant diseases to staff in the catheter laboratory. The RADPAD is a sterile surgical drape that reduces the effect of scatter radiation on the operator. We sought to assess the efficacy of RADPAD shields in reducing radiation dose experienced by operators during routine diagnostic coronary angiography. Sixty consecutive patients due to undergo elective coronary angiography were randomized in a 1:1 pattern to have their procedures performed with and without the RADPAD drape in situ. Dosimetry was performed on the left arm of the primary operator. There was no significant difference in the two main determents of radiation exposure in both groups: the screening times (102 ± 86 s for the RADPAD group vs. 105 ± 36 s for the control group, p = 0.9) and body mass index (BMI; 27.7 ± 4.2 kg/m 2 for the RADPAD group vs. 27.9 ± 5.5 kg/m 2 for the control group, p = 0.8). Moreover, there was no difference in the dose-area ratio (1337 ± 582 cGy/cm 2 for the RADPAD group vs. 1541 ± 804 cGy/cm 2 for the control group, p = 0.3) between the two patient groups. The primary operator radiation dose was significantly lower in the RADPAD group at 8.0 µSv (Q1: 3.2, Q3: 20.1) compared with 19.6 µSv (Q1: 7.1, Q3: 37.7) for the control group (p = 0.02). The RADPAD significantly reduces radiation exposure to primary operators during routine diagnostic coronary angiography in patients with a BMI > 25 kg/m 2 . It reduces total radiation exposure to primary operators by 59%, and the radiation exposure rate by 47%.

  15. X-ray intravital microscopy for functional imaging in rat hearts using synchrotron radiation coronary microangiography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Umetani, K.; Fukushima, K.

    2013-03-15

    An X-ray intravital microscopy technique was developed to enable in vivo visualization of the coronary, cerebral, and pulmonary arteries in rats without exposure of organs and with spatial resolution in the micrometer range and temporal resolution in the millisecond range. We have refined the system continually in terms of the spatial resolution and exposure time. X-rays transmitted through an object are detected by an X-ray direct-conversion type detector, which incorporates an X-ray SATICON pickup tube. The spatial resolution has been improved to 6 {mu}m, yielding sharp images of small arteries. The exposure time has been shortened to around 2 msmore » using a new rotating-disk X-ray shutter, enabling imaging of beating rat hearts. Quantitative evaluations of the X-ray intravital microscopy technique were extracted from measurements of the smallest-detectable vessel size and detection of the vessel function. The smallest-diameter vessel viewed for measurements is determined primarily by the concentration of iodinated contrast material. The iodine concentration depends on the injection technique. We used ex vivo rat hearts under Langendorff perfusion for accurate evaluation. After the contrast agent is injected into the origin of the aorta in an isolated perfused rat heart, the contrast agent is delivered directly into the coronary arteries with minimum dilution. The vascular internal diameter response of coronary arterial circulation is analyzed to evaluate the vessel function. Small blood vessels of more than about 50 {mu}m diameters were visualized clearly at heart rates of around 300 beats/min. Vasodilation compared to the control was observed quantitatively using drug manipulation. Furthermore, the apparent increase in the number of small vessels with diameters of less than about 50 {mu}m was observed after the vasoactive agents increased the diameters of invisible small blood vessels to visible sizes. This technique is expected to offer the potential for

  16. Targeting clinical outcomes: Endovascular simulation improves diagnostic coronary angiography skills.

    PubMed

    Schimmel, Daniel R; Sweis, Ranya; Cohen, Elaine R; Davidson, Charles; Wayne, Diane B

    2016-02-15

    The purpose of this study is to determine the effects of simulation-based medical education (SBME) on the skills required to perform coronary angiography in the cardiac catheterization laboratory. Cardiovascular fellows commonly learn invasive procedures on patients. Because this approach is not standardized, it can result in inconsistent skill acquisition through exclusion of concepts and skills. Also, the learning curve varies between trainees yielding variability in skill acquisition. Therefore, coronary angiography skills are an excellent target for SBME in an environment in which direct patient care is not jeopardized. From January 2013 to June 2013, 14 cardiovascular fellows entering the cardiac catheterization laboratory at a tertiary care teaching hospital were tested on an endovascular simulator to assess baseline skills. All fellows subsequently underwent didactic teaching and preceptor-lead training on the endovascular simulator. Topics included basic catheterization skills and a review of catheterization laboratory systems. Following training, all fellows underwent a post-training assessment on the endovascular simulator. Paired t tests were used to compare items on the skills checklist and simulator defined variables. Cardiovascular fellows scored significantly higher on a diagnostic coronary angiography skills checklist following SBME using an endovascular simulator. The mean pretest score was 66.6% (SD = 9.7%) compared to 86.0% (SD = 6.3%) following simulator training (P < 0.001). Additional findings include significant reduction in procedure time and use of cine-fluoroscopy at posttest. SBME significantly improved cardiovascular fellows' performance of simulated coronary angiography skills. Standardized simulation-based education is a valuable adjunct to traditional clinical education for cardiovascular fellows. © 2015 Wiley Periodicals, Inc.

  17. Relationship between the Self-Rating Anxiety Scale score and the success rate of 64-slice computed tomography coronary angiography.

    PubMed

    Li, Hui; Jin, Dan; Qiao, Fang; Chen, Jianchang; Gong, Jianping

    Computed tomography coronary angiography, a key method for obtaining coronary artery images, is widely used to screen for coronary artery diseases due to its noninvasive nature. In China, 64-slice computed tomography systems are now the most common models. As factors that directly affect computed tomography performance, heart rate and rhythm control are regulated by the autonomic nervous system and are highly related to the emotional state of the patient. The aim of this prospective study is to use a pre-computed tomography scan Self-Rating Anxiety Scale assessment to analyze the effects of tension and anxiety on computed tomography coronary angiography success. Subjects aged 18-85 years who were planned to undergo computed tomography coronary angiography were enrolled; 1 to 2 h before the computed tomography scan, basic patient data (gender, age, heart rate at rest, and family history) and Self-Rating Anxiety Scale score were obtained. The same group of imaging department doctors, technicians, and nurses performed computed tomography coronary angiography for all the enrolled subjects and observed whether those subjects could finish the computed tomography coronary angiography scan and provide clear, diagnostically valuable images. Participants were divided into successful (obtained diagnostically useful coronary images) and unsuccessful groups. Basic data and Self-Rating Anxiety Scale scores were compared between the groups. The Self-Rating Anxiety Scale standard score of the successful group was lower than that of the unsuccessful group (P = 0.001). As the Self-Rating Anxiety Scale standard score rose, the success rate of computed tomography coronary angiography decreased. The Self-Rating Anxiety Scale score has a negative relationship with computed tomography coronary angiography success. Anxiety can be a disadvantage in computed tomography coronary angiography examination. The pre-computed tomography coronary angiography scan Self-Rating Anxiety Scale

  18. Gender differences in coronary plaque composition by coronary computed tomography angiography.

    PubMed

    Blaha, Michael J; Nasir, Khurram; Rivera, Juan J; Choi, Eue-Keun; Chang, Sung-A; Yoon, Yeonyee E; Chun, Eun Ju; Choi, Sang-il; Agatston, Arthur; Blumenthal, Roger S; Chang, Hyuk-Jae

    2009-12-01

    Coronary computed tomography angiography allows the differentiation of non-calcified (NCAP), calcified (CAP), and mixed coronary artery plaques (MCAP). Although males are thought to have a higher prevalence of atherosclerosis for a given age, there are currently few data regarding age-adjusted sex differences in plaque morphology and composition. We studied 1015 consecutive asymptomatic South Korean patients (49+/-10 years, 64% men) who underwent 64-slice coronary computed tomography angiography during a routine health evaluation. Coronary plaque characteristics were analyzed on a per-segment basis according to the modified AHA classification. Plaques with more than 50% calcified tissue were classified as CAP, plaques with less than 50% calcified tissue were classified as MCAP, and plaques without calcium were classified as NCAP. Multiple regression analysis was used to describe the cross-sectional association between sex and plaque-type burden (>or=2 affected segments) after adjustment for age and other cardiovascular risk factors. There was a greater prevalence of coronary plaque among men (13 vs. 4%, P<0.001). Males were more likely to have an increased burden of CAP (4 vs. 1%, P = 0.01) and MCAP (5 vs. 1%, P<0.001), whereas the burden of NCAP was similar across sex (2 vs. 1%, P = 0.28). After multivariable adjustment, men have six to seven times greater odds of having an increased burden of CAP and MCAP, whereas no sex difference was observed in the burden of NCAP. In this population of asymptomatic middle-aged Korean individuals, males had a significantly greater burden of MCAP and CAP. Future studies will determine whether these differences contribute to the accelerated cardiovascular risk observed in men.

  19. Effectiveness of Fluorography versus Cineangiography at Reducing Radiation Exposure During Diagnostic Coronary Angiography

    PubMed Central

    Shah, Binita; Mai, Xingchen; Tummala, Lakshmi; Kliger, Chad; Bangalore, Sripal; Miller, Louis H.; Sedlis, Steven P.; Feit, Frederick; Liou, Michael; Attubato, Michael; Coppola, John; Slater, James

    2014-01-01

    Coronary angiography is the gold standard for defining obstructive coronary disease. However, radiation exposure remains an unwanted hazard. Patients referred for coronary angiography with abdominal circumference <45 inches and glomerular filtration rate >60mL/min were randomized to the Fluorography (n=25) or Cineangiography (n=25) group. Patients in the Fluorography group underwent coronary angiography using retrospectively-stored fluorography with repeat injection under cineangiography only when needed for better resolution per operator’s discretion. Patients in the Cineangiography group underwent coronary angiography using routine cineangiography. The primary endpoint was patient radiation exposure measured by radiochromic film. Secondary endpoints included the radiation output measurement of kerma-area product (KAP) and air kerma at the interventional reference point (Ka,r), and operator radiation exposure measured by dosimeter. Patient radiation exposure (158.2mGy [76.5–210.2] vs 272.5mGy [163.3–314.0], p=0.001), KAP (1323μGy m2 [826–1765] vs 3451μGy m2 [2464–4818], p<0.001), and Ka,r (175 mGy [112–252] vs 558 mGy [313–621], p<0.001)was significantly lower in the Fluorography compared with Cineangiography group (42%, 62%, and 69% relative reduction, respectively). Operator radiation exposure trended in the same direction though statistically non-significant (Fluorography 2.35 μGy [1.24–6.30] vs Cineangiography 5.03μGy [2.48–7.80], p=0.059). In conclusion, the use of fluorography in a select group of patients during coronary angiography with repeat injection under cineangiography only when needed was efficacious at reducing patient radiation exposure. PMID:24513469

  20. Accuracy of computed tomographic angiography for stenosis quantification using quantitative coronary angiography or intravascular ultrasound as the gold standard.

    PubMed

    Joshi, Subodh B; Okabe, Teruo; Roswell, Robert O; Weissman, Gaby; Lopez, Cristian F; Lindsay, Joseph; Pichard, Augusto D; Weissman, Neil J; Waksman, Ron; Weigold, Wm Guy

    2009-10-15

    Computed tomographic angiography (CTA) is considered to have limited accuracy for quantifying exact percent diameter stenosis in coronary arteries. However, most studies evaluating CTA use quantitative coronary angiography (QCA) as the gold standard, a technique with its own limitations. We sought to determine whether CTA measurements of stenosis severity correlate better with intravascular ultrasound (IVUS) than with QCA. Luminal dimensions of 67 de novo coronary lesions were measured by CTA, IVUS, and QCA. IVUS was performed when lesion severity by angiography was equivocal. Mean percent diameter stenosis by QCA was 51 +/- 9.8% and mean IVUS minimal luminal area was 3.8 +/- 1.8 mm(2). There was a moderate correlation between CTA minimal luminal area and IVUS minimal luminal area (r(2) = 0.41, p <0.001), but no relation between CTA and QCA measurements of minimal luminal diameter (r(2) = 0.01, p = 0.57) or diameter stenosis (r(2) = 0.02, p = 0.31). There was also no relation between IVUS minimal luminal area and QCA diameter stenosis (r(2) = 0.01, p = 0.50). When lesions with moderate or severe calcification were excluded, the correlation between CTA minimal luminal area and IVUS minimal luminal area was good (r(2) = 0.68, p <0.001). In conclusion, in this cohort of patients with intermediate-grade lesions on cardiac catheterization, absolute measurements of stenosis severity on CTA correlated with IVUS but not with QCA. Our findings suggest that limitations of quantitative coronary angiography as a gold standard need to be considered in studies evaluating the accuracy of coronary CTA.

  1. Coronary angiography in Qatar: the first ten years.

    PubMed

    Chaikhouni, A; Gehani, A A; Horak, J; Hajar, H A

    1998-08-01

    Cardiac catheterization in Qatar was initiated in July 1982. In ten years, a total of 3900 procedures were performed at Hamad General Hospital. Computerized data registry has been maintained since 1982. Isolated coronary angiography was done in 2911 patients; of these, 2635 (90.5%) were men, and 276 (9.5%) were women, the average age of the patients was 47+/-9.2 years (range, twenty-five to eighty-eight). Patients' nationality was Qatari in 492 (17%), and other Arabs in 610 (21%), and 1512 (52%) were from the Asian subcontinent. Myocardial infarction was the most common indication (43%). Single-vessel disease was found in 638 (22%), two-vessel disease in 630 (22%), three-vessel disease in 950 (33%), and nonsignificant coronary artery disease in 693 (24%) patients. Morbidity related to the coronary angiography was reported in 147 (5%) patients, but there was no mortality related to the procedure. In 822 (28%) patients, the age was forty years or younger. The angiographic findings of these younger patients were compared with those of the older ones. Younger patients were usually men of Asian subcontinental origin with a recent myocardial infarction (MI). Often, they had normal coronary arteries or single-vessel disease. Patients of Asian subcontinent origin were usually young male patients with a recent MI, who receive streptokinase, and have single-vessel disease.

  2. A randomized-controlled trial examining the effects of reflexology on anxiety of patients undergoing coronary angiography.

    PubMed

    Molavi Vardanjani, Mehdi; Masoudi Alavi, Negin; Razavi, Narges Sadat; Aghajani, Mohammad; Azizi-Fini, Esmail; Vaghefi, Seied Morteza

    2013-09-01

    The anxiety reduction before coronary angiography has clinical advantages and is one of the objectives of nursing. Reflexology is a non-invasive method that has been used in several clinical situations. Applying reflexology might have effect on the reduction of anxiety before coronary angiography. The aim of this randomized clinical trial was to investigate the effect of reflexology on anxiety among patients undergoing coronary angiography. This trial was conducted in Shahid Beheshti Hospital, in Kashan, Iran. One hundred male patients who were undergoing coronary angiography were randomly enrolled into intervention and placebo groups. The intervention protocol was included 30 minutes of general foot massage and the stimulation of three reflex points including solar plexus, pituitary gland, and heart. The placebo group only received the general foot massage. Spielbergers state trait anxiety inventory was used to assess the anxiety experienced by patients. Data was analyzed using Man-Witney, Wilcoxon and Chi-square tests. The stepwise multiple regressions used to analyze the variables that are involved in anxiety reduction. The mean range of anxiety decreased from 53.24 to 45.24 in reflexology group which represented 8 score reduction (P = 0.0001). The reduction in anxiety was 5.9 score in placebo group which was also significant (P = 0.0001). The anxiety reduction was significantly higher in reflexology group (P = 0.014). The stepwise multiple regression analysis showed that doing reflexology can explain the 7.5% of anxiety reduction which made a significant model. Reflexology can decrease the anxiety level before coronary angiography. Therefore, reflexology before coronary angiography is recommended.

  3. Cerebral angiography

    MedlinePlus

    ... Carotid angiogram; Cervicocerebral catheter-based angiography; Intra-arterial digital subtraction angiography; IADSA ... with the dye are seen. This is called digital subtraction angiography (DSA). After the x-rays are ...

  4. Coronary CT angiography using 64 detector rows: methods and design of the multi-centre trial CORE-64.

    PubMed

    Miller, Julie M; Dewey, Marc; Vavere, Andrea L; Rochitte, Carlos E; Niinuma, Hiroyuki; Arbab-Zadeh, Armin; Paul, Narinder; Hoe, John; de Roos, Albert; Yoshioka, Kunihiro; Lemos, Pedro A; Bush, David E; Lardo, Albert C; Texter, John; Brinker, Jeffery; Cox, Christopher; Clouse, Melvin E; Lima, João A C

    2009-04-01

    Multislice computed tomography (MSCT) for the noninvasive detection of coronary artery stenoses is a promising candidate for widespread clinical application because of its non-invasive nature and high sensitivity and negative predictive value as found in several previous studies using 16 to 64 simultaneous detector rows. A multi-centre study of CT coronary angiography using 16 simultaneous detector rows has shown that 16-slice CT is limited by a high number of nondiagnostic cases and a high false-positive rate. A recent meta-analysis indicated a significant interaction between the size of the study sample and the diagnostic odds ratios suggestive of small study bias, highlighting the importance of evaluating MSCT using 64 simultaneous detector rows in a multi-centre approach with a larger sample size. In this manuscript we detail the objectives and methods of the prospective "CORE-64" trial ("Coronary Evaluation Using Multidetector Spiral Computed Tomography Angiography using 64 Detectors"). This multi-centre trial was unique in that it assessed the diagnostic performance of 64-slice CT coronary angiography in nine centres worldwide in comparison to conventional coronary angiography. In conclusion, the multi-centre, multi-institutional and multi-continental trial CORE-64 has great potential to ultimately assess the per-patient diagnostic performance of coronary CT angiography using 64 simultaneous detector rows.

  5. Latest-generation catheterization systems enable invasive submillisievert coronary angiography.

    PubMed

    Kuon, E; Weitmann, K; Hummel, A; Dörr, M; Reffelmann, T; Riad, A; Busch, M C; Felix, S B; Hoffmann, W; Empen, K

    2015-05-01

    The radiation risk of patients undergoing invasive cardiology remains considerable and includes skin injuries and cancer. To date, submillisievert coronary angiography has not been considered feasible. In 2011, we compared results from 100 consecutive patients undergoing elective coronary angiography using the latest-generation flat-panel angiography system (FPS) with results from examinations by the same operator using 106 historic controls with a conventional image-intensifier system (IIS) that was new in 2002. The median patient exposure parameters were measured as follows: dose-area product (DAP) associated with radiographic cine acquisitions (DAP(R)) and fluoroscopy (DAP(F)) scenes, radiographic frames and runs, and cumulative exposure times for radiography and fluoroscopy. On the FPS as compared to the traditional IIS, radiographic detector entrance dose levels were reduced from 164 to 80 nGy/frame and pulse rates were lowered from 12.5/s to 7.5/s during radiography and from 25/s to 4/s during fluoroscopy. The cardiologist's performance patterns remained comparable over the years: fluoroscopy time was constant and radiography time even slightly increased. Overall patient DAP decreased from 7.0 to 2.4 Gy × cm(2); DAP(R), from 4.2 to 1.7 Gy × cm(2); and DAP(F), from 2.8 to 0.6 Gy × cm(2). Time-adjusted DAP(R)/s decreased from 436 to 130 mGy × cm(2) and DAP(F)/s, from 21.6 to 4.4 mGy × cm(2). Cumulative patient skin dose with the FPS amounted to 67 mGy, and the median (interquartile range) of effective dose was 0.5 (0.3 … 0.7) mSv. Consistent application of radiation-reducing techniques with the latest-generation flat-panel systems enables submillisievert coronary angiography in invasive cardiology.

  6. A Randomized-Controlled Trial Examining the Effects of Reflexology on Anxiety of Patients Undergoing Coronary Angiography

    PubMed Central

    Molavi Vardanjani, Mehdi; Masoudi Alavi, Negin; Razavi, Narges Sadat; Aghajani, Mohammad; Azizi-Fini, Esmail; Vaghefi, Seied Morteza

    2013-01-01

    Background: The anxiety reduction before coronary angiography has clinical advantages and is one of the objectives of nursing. Reflexology is a non-invasive method that has been used in several clinical situations. Applying reflexology might have effect on the reduction of anxiety before coronary angiography. Objectives: The aim of this randomized clinical trial was to investigate the effect of reflexology on anxiety among patients undergoing coronary angiography. Patients and Methods: This trial was conducted in Shahid Beheshti Hospital, in Kashan, Iran. One hundred male patients who were undergoing coronary angiography were randomly enrolled into intervention and placebo groups. The intervention protocol was included 30 minutes of general foot massage and the stimulation of three reflex points including solar plexus, pituitary gland, and heart. The placebo group only received the general foot massage. Spielbergers state trait anxiety inventory was used to assess the anxiety experienced by patients. Data was analyzed using Man-Witney, Wilcoxon and Chi-square tests. The stepwise multiple regressions used to analyze the variables that are involved in anxiety reduction. Results: The mean range of anxiety decreased from 53.24 to 45.24 in reflexology group which represented 8 score reduction (P = 0.0001). The reduction in anxiety was 5.9 score in placebo group which was also significant (P = 0.0001). The anxiety reduction was significantly higher in reflexology group (P = 0.014). The stepwise multiple regression analysis showed that doing reflexology can explain the 7.5% of anxiety reduction which made a significant model. Conclusions: Reflexology can decrease the anxiety level before coronary angiography. Therefore, reflexology before coronary angiography is recommended. PMID:25414869

  7. Model based LV-reconstruction in bi-plane x-ray angiography

    NASA Astrophysics Data System (ADS)

    Backfrieder, Werner; Carpella, Martin; Swoboda, Roland; Steinwender, Clemens; Gabriel, Christian; Leisch, Franz

    2005-04-01

    Interventional x-ray angiography is state of the art in diagnosis and therapy of severe diseases of the cardiovascular system. Diagnosis is based on contrast enhanced dynamic projection images of the left ventricle. A new model based algorithm for three dimensional reconstruction of the left ventricle from bi-planar angiograms was developed. Parametric super ellipses are deformed until their projection profiles optimally fit measured ventricular projections. Deformation is controlled by a simplex optimization procedure. A resulting optimized parameter set builds the initial guess for neighboring slices. A three dimensional surface model of the ventricle is built from stacked contours. The accuracy of the algorithm has been tested with mathematical phantom data and clinical data. Results show conformance with provided projection data and high convergence speed makes the algorithm useful for clinical application. Fully three dimensional reconstruction of the left ventricle has a high potential for improvements of clinical findings in interventional cardiology.

  8. Insufficient platelet inhibition is related to silent embolic cerebral infarctions after coronary angiography.

    PubMed

    Kim, Bum Joon; Lee, Seung-Whan; Park, Seong-Wook; Kang, Dong-Wha; Kim, Jong S; Kwon, Sun U

    2012-03-01

    Considering that insufficient platelet inhibition is related to thrombotic complications after coronary angiography, we hypothesized that the extent of platelet inhibition by antiplatelet agents is related to the occurrence of silent embolic cerebral infarction (SECI) after coronary angiography. Among the patients scheduled for coronary artery bypass surgery, we retrospectively analyzed the location of SECI on diffusion-weighted imaging of 272 patients, which was performed after coronary angiography, as a presurgical evaluation in Phase 1 study. In Phase 2 study, we have prospectively recruited 102 patients to compare the extent of platelet inhibition measured by the VerifyNow system among patients with and without SECI. SECI is observed in 45 patients (16.5%) in Phase 1 and 17 (16.7%) in Phase 2. The lesions were slightly more frequent in the right hemisphere. In the Phase 2 study, aspirin reaction units and P(2)Y(12) reaction units were higher in the patients with SECI than those without (aspirin reaction units: 490±72 versus 446±53, P=0.03; P(2)Y(12) reaction units: 352±65 versus 300±77, P=0.009). The incidence of SECI increased with the number of resistant antiplatelets; resistance to both antiplatelet agent (50%), resistance to 1 antiplatelet agent (22%), and no resistance (4%; P=0.023). From the result of logistic regression, higher aspirin reaction units, white blood cell count, low hemoglobin, and nonresponsiveness to antiplatelet agents were independent risk factors. Insufficient platelet inhibition after administration of antiplatelet agents is related with SECI appearing after coronary angiography.

  9. Effect of radiographic contrast media on markers of complement activation and apoptosis in patients with chronic coronary artery disease undergoing coronary angiography.

    PubMed

    Deftereos, Spyridon; Giannopoulos, Georgios; Kossyvakis, Charalampos; Raisakis, Konstantinos; Kaoukis, Andreas; Driva, Metaxia; Ntzouvara, Olga; Panagopoulou, Vasiliki; Rentoukas, Ilias; Nikas, Dimitrios J; Pyrgakis, Vlasios; Alpert, Martin A

    2009-09-01

    The effects of radiographic contrast media on markers of complement activation and apoptosis in patients with chronic coronary artery disease (CAD) are unknown. The purpose of this study was to assess the comparative effects of ionic high-osmolar and non-ionic iso-osmolar radiographic contrast media on plasma markers of complement activation and apoptosis in patients with chronic CAD undergoing coronary angiography. Forty-four patients undergoing coronary angiography for chronic CAD were randomly assigned to receive the ionic high-osmolar radiographic contrast agent diatrizoate (Group A), or the non-ionic iso-osmolar contrast agent iodixanol (Group B) during angiography. Complement component 5 (C5a) and apoptotic markers sFas and sFasL were measured just prior to angiography and 1 hour after completion of angiography. Comparison of mean pre- and post-angiography plasma marker levels showed significantly greater increases in plasma levels in Group A than in Group B of C5a (29.30 +/- 5.45 ng/ml for Group A and 0.47 +/- 0.70 ng/ml for Group B (p < 0.00001), sFas (2.36 +/- 1.63 ng/ml for Group A and 0.23 +/- 0.90 ng/ml for Group B (p < 0.00001) and sFasL (14.00 +/- 5.41 pg/ml for Group A and 0.01 +/- 1.00 pg/ml for Group B (p < 0.00001). The results suggest that in patients with chronic CAD, the use of ionic high-osmolar radiographic contrast media during coronary angiography is associated with a more robust inflammatory and apoptotic milieu than that associated with the use of non-ionic iso-osmolar radiographic contrast media.

  10. Arterial Access in Patients With De Novo Acute Coronary Syndrome Undergoing Coronary Angiography.

    PubMed

    Abdul Jabbar, Ali; Mufti, Omar; Sabol, Angeline; Markert, Ronald; White, Bryan; Broderick, George

    2017-04-01

    Bleeding is a major limitation of antithrombotic therapy among invasively managed patients with non-ST-segment elevation acute coronary syndromes (NSTE-ACSs). Randomized clinical trials have generally failed to favor either the femoral or the radial arterial approach for coronary angiography or intervention in NSTE-ACS. In 561 hospitalized patients with a new diagnosis of NSTE-ACS referred for coronary angiography, 364 and 197 patients underwent the femoral and the radial approach, respectively. Femoral and radial access did not differ in bleeding complications in the first 72 hours (8 of 364 or 2.2% vs 8 of 197 or 4.1%, P = .21), duration of hospitalization (4.67 ± 5.02 vs 4.51 ± 4.81, P = .28) nor in-hospital mortality (0.8% vs 0.5%, P = .67). Contrast volume was higher for femoral versus radial cases (204 ± 119 vs 168 ± 104, P < .001). In patients with de novo NSTE-ACS without prior cardiac bypass, radial and femoral arterial access did not differ in instances of bleeding within the first 72 hours postoperatively, length of hospital stay, or in-hospital mortality. Less contrast was used in radial cases, which may represent an advantage for patients with renal insufficiency.

  11. Coronary vasodilation by the use of sublingual nitroglycerin using 64-slice dual-source coronary computed tomography angiography.

    PubMed

    Okada, Munemasa; Nakashima, Yoshiteru; Nomura, Takafumi; Miura, Toshiro; Nao, Tomoko; Yoshimura, Masayuki; Sano, Yuichi; Matsunaga, Naofumi

    2015-03-01

    Sublingual nitroglycerin capsules or spray is routinely used to treat anginal attacks and to maximally dilate the epicardial coronary arteries during coronary angiography. These dilated coronary vessels have an advantage, but increased heart rates were disadvantageous for coronary computed tomography angiography (CTA). The influence of applying nitroglycerin was analyzed regarding the coronary diameter, coronary luminal attenuation, evaluable number of coronary segments, heart rate (HR), HR variability, the optimal reconstruction phase, and image scoring of CTA in the same patients using a 64-slice dual-source CT. Fifty-two patients with atypical chest pain underwent coronary CTA before and after the administration of sublingual nitroglycerin without heart rate control. The coronary diameter and luminal attenuation were measured on short-axial images in each coronary segment. The coronary vasodilation ratios (VRs) were calculated from the coronary diameters at the same location before and after the use of nitroglycerin. The local institutional review board approved this study and written informed consent was obtained from all the patients. No significant differences were noted in the HR variability or optimal reconstruction phase, despite an increase in HR after the use of nitroglycerin. Nitroglycerin significantly enlarged the coronary artery diameter, and VRs of each coronary segment ranged from 7.54% to 22.26%. As compared with baseline coronary diameter, VRs of minor segments (16.91%) were significantly larger than those of major segments (11.35%), and the magnitude of VR correlated with the baseline coronary diameter (r=-0.48, p<0.001). Coronary luminal attenuation significantly increased due to additional administration of contrast material after the use of nitroglycerin (p<0.01), but no significant difference was noted in the image quality after the use of nitroglycerin. Sublingual nitroglycerin significantly enlarged the coronary diameters, especially in

  12. Coronary artery wall imaging.

    PubMed

    Keegan, Jennifer

    2015-05-01

    Like X-Ray contrast angiography, MR coronary angiograms show the vessel lumens rather than the vessels themselves. Consequently, outward remodeling of the vessel wall, which occurs in subclinical coronary disease before luminal narrowing, cannot be seen. The current gold standard for assessing the coronary vessel wall is intravascular ultrasound, and more recently, optical coherence tomography, both of which are invasive and use ionizing radiation. A noninvasive, low-risk technique for assessing the vessel wall would be beneficial to cardiologists interested in the early detection of preclinical disease and for the safe monitoring of the progression or regression of disease in longitudinal studies. In this review article, the current state of the art in MR coronary vessel wall imaging is discussed, together with validation studies and recent developments. © 2014 Wiley Periodicals, Inc.

  13. The role of vaspin as a predictor of coronary angiography result in SCAD (stable coronary artery disease) patients.

    PubMed

    Stančík, Matej; Ságová, Ivana; Kantorová, Ema; Mokáň, Marián

    2017-05-08

    The role of vaspin in the pathogenesis of stable coronary artery disease (SCAD) have been repeatedly addressed in clinical studies. However, from the point of view of clinical practice, the results of earlier studies are still inconclusive. The data of 106 SCAD patients who received coronary angiography and 85 coronary artery disease-free controls were collected and analysed. The patients were divided into subgroups according to their pre-test probability (PTP) and according to the result of coronary angiography. Fasting vaspin concentrations were compared between subgroups of SCAD patients and between target group and controls. The effect of age and smoking on the result of coronary angiography was compared to the effect of vaspin using the binomial regression. We did not find significant difference in vaspin level between target group and controls. Unless the pre-test probability was taken into account, we did not find vaspin difference in the target group, when dividing patients on the basis of presence/absence of significant coronary stenosis. In the subgroup of SCAD patients with PTP between 15% - 65%, those with significant coronary stenoses had higher mean vaspin concentration (0,579 ± 0,898 ng/ml) than patients without significant stenoses. (0,379 ± 0,732 ng/ml) (t = -2595; p = 0,012; d = 0,658; 1-β = 0,850). Age, smoking status and vaspin significantly contributed to the HSCS prediction in binomial regression model in patients with low PTP (OR: 1.1, 4.9, 8.7, respectively). According to our results, vaspin cannot be used as an independent marker for the presence of CAD in general population. However, our results indicate that measuring vaspin in SCAD patients might be clinically useful in patients with PTP below 66%.

  14. Prevalence and predictors of renal artery stenosis in patients undergoing peripheral and coronary angiography.

    PubMed

    Shukla, Anand N; Madan, Tarun H; Jayaram, Ashwal A; Kute, Vivek B; Rawal, Jayesh R; Manjunath, A P; Udhreja, Satyam

    2013-12-01

    Renal artery stenosis is a potential cause of secondary hypertension, ischemic nephropathy and end-stage renal disease. Atherosclerosis is by far the most common etiology of renal artery stenosis in elderly. We investigated whether the presence of significant atherosclerotic renal artery stenosis (ARAS) with luminal diameter narrowing ≥50 % could be predicted in patients undergoing peripheral and coronary angiography. The records of 3,500 consecutive patients undergoing simultaneous renal angiography along with peripheral and coronary angiography were reviewed. The patients with known renal artery disease were excluded. Prevalence of ARAS was 5.7 %. Significant ARAS (luminal diameter narrowing ≥50 %) was present in 139 patients (3.9 %). Hypertension with altered serum creatinine and triple-vessel CAD were associated with significant renal artery stenosis in multivariate analysis. No significant relationship between the involved coronary arteries like left anterior descending, left circumflex, right coronary artery and ARAS was found. Only hypertension and altered serum creatinine were associated with bilateral ARAS. Extent of CAD or risk factors like diabetes, hyperlipidemia or smoking did not predict the unilateral or bilateral ARAS. Prevalence of ARAS among the patients in routine cardiac catheterization was 5.7 %. Hypertension is closely associated with significant ARAS. Significant CAD in the form of triple-vessel disease and altered renal function tests are closely associated with ARAS. They predict the presence of significant renal artery stenosis in patients undergoing routine peripheral and coronary angiography. Moreover, hypertension and altered renal functions predict bilateral ARAS.

  15. Cardiothoracic ratio within the “normal” range independently predicts mortality in patients undergoing coronary angiography

    PubMed Central

    Zaman, M Justin S; Sanders, Julie; Crook, Angela M; Feder, Gene; Shipley, Martin; Timmis, Adam; Hemingway, Harry

    2007-01-01

    Objective To determine whether cardiothoracic ratio (CTR), within the range conventionally considered normal, predicted prognosis in patients undergoing coronary angiography. Design Cohort study with a median of 7‐years follow‐up. Setting Consecutive patients undergoing coronary angiography at Barts and The London National Health Service (NHS) Trust. Subjects 1005 patients with CTRs measured by chest radiography, and who subsequently underwent coronary angiography. Of these patients, 7.3% had a CTR ⩾0.5 and were excluded from the analyses. Outcomes All‐cause mortality and coronary event (non‐fatal myocardial infarction or coronary death). Adjustments were made for age, left ventricular dysfunction, ACE inhibitor treatment, body mass index, number of diseased coronary vessels and past coronary artery bypass graft. Results The risk of death was increased among patients with a CTR in the upper part of the normal range. In total, 94 (18.9%) of those with a CTR below the median of 0.42 died compared with 120 (27.8%) of those with a CTR between 0.42 and 0.49 (log rank test p<0.001). After adjusting for potential confounders, this increased risk remained (adjusted HR 1.45, 95% CI 1.03 to 2.05). CTR, at values below 0.5, was linearly related to the risk of coronary event (test for trend p = 0.024). Conclusion : In patients undergoing coronary angiography, CTR between 0.42 and 0.49 was associated with higher mortality than in patients with smaller hearts. There was evidence of a continuous increase in risk with higher CTR. These findings, along with those in healthy populations, question the conventional textbook cut‐off point of ⩾0.5 being an abnormal CTR. PMID:17164481

  16. Risks and Complications of Coronary Angiography: A Comprehensive Review

    PubMed Central

    Tavakol, Morteza; Ashraf, Salman; Brener, Sorin J.

    2012-01-01

    Coronary angiography and heart catheterization are invaluable tests for the detection and quantification of coronary artery disease, identification of valvular and other structural abnormalities, and measurement of hemodynamic parameters. The risks and complications associated with these procedures relate to the patient’s concomitant conditions and to the skill and judgment of the operator. In this review, we examine in detail the major complications associated with invasive cardiac procedures and provide the reader with a comprehensive bibliography for advanced reading. PMID:22980117

  17. Noninvasive Fractional Flow Reserve Derived From Coronary CT Angiography: Clinical Data and Scientific Principles.

    PubMed

    Min, James K; Taylor, Charles A; Achenbach, Stephan; Koo, Bon Kwon; Leipsic, Jonathon; Nørgaard, Bjarne L; Pijls, Nico J; De Bruyne, Bernard

    2015-10-01

    Fractional flow reserve derived from coronary computed tomography angiography enables noninvasive assessment of the hemodynamic significance of coronary artery lesions and coupling of the anatomic severity of a coronary stenosis with its physiological effects. Since its initial demonstration of feasibility of use in humans in 2011, a significant body of clinical evidence has developed to evaluate the diagnostic performance of coronary computed tomography angiography-derived fractional flow reserve compared with an invasive fractional flow reserve reference standard. The purpose of this paper was to describe the scientific principles and to review the clinical data of this technology recently approved by the U.S. Food and Drug Administration. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  18. Direct costs and cost-effectiveness of dual-source computed tomography and invasive coronary angiography in patients with an intermediate pretest likelihood for coronary artery disease.

    PubMed

    Dorenkamp, Marc; Bonaventura, Klaus; Sohns, Christian; Becker, Christoph R; Leber, Alexander W

    2012-03-01

    The study aims to determine the direct costs and comparative cost-effectiveness of latest-generation dual-source computed tomography (DSCT) and invasive coronary angiography for diagnosing coronary artery disease (CAD) in patients suspected of having this disease. The study was based on a previously elaborated cohort with an intermediate pretest likelihood for CAD and on complementary clinical data. Cost calculations were based on a detailed analysis of direct costs, and generally accepted accounting principles were applied. Based on Bayes' theorem, a mathematical model was used to compare the cost-effectiveness of both diagnostic approaches. Total costs included direct costs, induced costs and costs of complications. Effectiveness was defined as the ability of a diagnostic test to accurately identify a patient with CAD. Direct costs amounted to €98.60 for DSCT and to €317.75 for invasive coronary angiography. Analysis of model calculations indicated that cost-effectiveness grew hyperbolically with increasing prevalence of CAD. Given the prevalence of CAD in the study cohort (24%), DSCT was found to be more cost-effective than invasive coronary angiography (€970 vs €1354 for one patient correctly diagnosed as having CAD). At a disease prevalence of 49%, DSCT and invasive angiography were equally effective with costs of €633. Above a threshold value of disease prevalence of 55%, proceeding directly to invasive coronary angiography was more cost-effective than DSCT. With proper patient selection and consideration of disease prevalence, DSCT coronary angiography is cost-effective for diagnosing CAD in patients with an intermediate pretest likelihood for it. However, the range of eligible patients may be smaller than previously reported.

  19. Prospective Coronary Heart Disease Screening in Asymptomatic Hodgkin Lymphoma Patients Using Coronary Computed Tomography Angiography: Results and Risk Factor Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Girinsky, Theodore, E-mail: girinsky.theodore@orange.fr; M’Kacher, Radhia; Lessard, Nathalie

    Purpose: To prospectively investigate the coronary artery status using coronary CT angiography (CCTA) in patients with Hodgkin lymphoma treated with combined modalities and mediastinal irradiation. Methods and Materials: All consecutive asymptomatic patients with Hodgkin lymphoma entered the study during follow-up, from August 2007 to May 2012. Coronary CT angiography was performed, and risk factors were recorded along with leukocyte telomere length (LTL) measurements. Results: One hundred seventy-nine patients entered the 5-year study. The median follow-up was 11.6 years (range, 2.1-40.2 years), and the median interval between treatment and the CCTA was 9.5 years (range, 0.5-40 years). Coronary artery abnormalities were demonstrated in 46 patientsmore » (26%). Coronary CT angiography abnormalities were detected in nearly 15% of the patients within the first 5 years after treatment. A significant increase (34%) occurred 10 years after treatment (P=.05). Stenoses were mostly nonostial. Severe stenoses were observed in 12 (6.7%) of the patients, entailing surgery with either angioplasty with stent placement or bypass grafting in 10 of them (5.5%). A multivariate analysis demonstrated that age at treatment, hypertension, and hypercholesterolemia, as well as radiation dose to the coronary artery origins, were prognostic factors. In the group of patients with LTL measurements, hypertension and LTL were the only independent risk factors. Conclusions: The findings suggest that CCTA can identify asymptomatic individuals at risk of acute coronary artery disease who might require either preventive or curative measures. Conventional risk factors and the radiation dose to coronary artery origins were independent prognostic factors. The prognostic value of LTL needs further investigation.« less

  20. Comparison of fluoro and cine coronary angiography: balancing acceptable outcomes with a reduction in radiation dose.

    PubMed

    Olcay, Ayhan; Guler, Ekrem; Karaca, Ibrahim Oguz; Omaygenc, Mehmet Onur; Kizilirmak, Filiz; Olgun, Erkam; Yenipinar, Esra; Cakmak, Huseyin Altug; Duman, Dursun

    2015-04-01

    Use of last fluoro hold (LFH) mode in fluoroscopy, which enables the last live image to be saved and displayed, could reduce radiation during percutaneous coronary intervention when compared with cine mode. No previous study compared coronary angiography radiation doses and image quality between LFH and conventional cine mode techniques. We compared cumulative dose-area product (DAP), cumulative air kerma, fluoroscopy time, contrast use, interobserver variability of visual assessment between LFH angiography, and conventional cine angiography techniques. Forty-six patients were prospectively enrolled into the LFH group and 82 patients into the cine angiography group according to operator decision. Mean cumulative DAP was higher in the cine group vs the LFH group (50058.98 ± 53542.71 mGy•cm² vs 11349.2 ± 8796.46 mGy•cm²; P<.001). Mean fluoroscopy times were higher in the cine group vs the LFH group (3.87 ± 5.08 minutes vs 1.66 ± 1.51 minutes; P<.01). Mean contrast use was higher in the cine group vs the LFH group (112.07 ± 43.79 cc vs 88.15 ± 23.84 cc; P<.001). Mean value of Crombach's alpha was not statistically different between visual estimates of three operators between cine and LFH angiography groups (0.66680 ± 0.19309 vs 0.54193 ± 0.31046; P=.20). Radiation doses, contrast use, and fluoroscopy times are lower in fluoroscopic LFH angiography vs cine angiography. Interclass variability of visual stenosis estimation between three operators was not different between cine and LFH groups. Fluoroscopic LFH images conventionally have inferior diagnostic quality when compared with cine coronary angiography, but with new angiographic systems with improved LFH image quality, these images may be adequate for diagnostic coronary angiography.

  1. Effectiveness of Chinese Hand Massage on Anxiety Among Patients Awaiting Coronary Angiography: A Randomized Controlled Trial.

    PubMed

    Mei, Lijuan; Miao, Xing; Chen, Haiying; Huang, Xiufang; Zheng, Guohua

    Anxiety is the most common negative emotion among the patients awaiting coronary angiography. The increased anxiety may exacerbate coronary heart disease symptoms and possibly contribute to complications during the procedure. Chinese hand massage is a nonpharmaceutical intervention that has been used in several clinical situations in China and might have beneficial effects on reducing anxiety before coronary angiography. The aim of this study was to evaluate the effectiveness and safety of Chinese hand massage care on anxiety among patients awaiting coronary angiography. One hundred eighty-five subjects awaiting coronary angiography in a single hospital in Fuzhou, China, between May 2012 and September 2012 were screened. One hundred eligible participants were recruited and randomly assigned into the control or Chinese hand massage group. The control group received the conventional therapies and care according to the guidelines, and those in the Chinese hand massage group received additional Chinese hand massage care in conjunction with the same conventional therapies and care as the control group. The anxiety scores (evaluated by using the Hamilton Anxiety Rating Scale), heart rate, blood pressure, quality of life (Short-Form Health Survey), and the adverse events were recorded at the baseline and after coronary angiography, respectively. The scores of Hamilton Anxiety Rating Scale in the Chinese hand massage group (11.78 [SD, 2.9]) had a statistically significant decrease compared with those in the control group (15.96 [SD, 3.4]) at post-procedure (P < .01). There was no statistically significant difference on blood pressure, heart rate, and Short-Form Health Survey at postangiography between the Chinese hand massage group and the control group. No adverse event was reported during the intervention period. Chinese hand massage effectively alleviated anxiety without any adverse effects among patients awaiting coronary angiography. Therefore, it might be recommended

  2. Clinical relevance of coronary angiography at the time of percutaneous closure of a patent foramen ovale.

    PubMed

    Wahl, Andreas; Praz, Fabien; Seiler, Christian; Windecker, Stephan; Meier, Bernhard

    2007-11-01

    The value of incidental coronary angiography during percutaneous shunt closure to screen for asymptomatic coronary artery disease (CAD) is unknown. On the occasion of percutaneous closure of patent foramen ovale (PFO), incidental coronary angiography routinely offered to men >40 and women >50 years, or younger patients with particular risk patterns, was performed in 575 patients (64% men, mean age 55 +/- 10 years, mean 1.5 +/- 1.1 cardiovascular risk factors) without overt history, signs, or symptoms of CAD. CAD was found in 164 patients (29%); 53 (9%) had >or=50% diameter stenoses. Thirty patients (5%) had one-vessel, 13 (2%) two-vessel, and 10 (2%) three-vessel disease. Patients with CAD (n = 164) were older (60 +/- 9 vs. 53 +/- 10 years; P < 0.0001), more frequently male (76% vs. 59%; P = 0.0002), and had a higher body mass index (26.5 +/- 4.0 vs. 25.4 +/- 4.6; P = 0.006) and more cardiovascular risk factors (2.0 +/- 1.1 vs. 1.2 +/- 1.0; P < 0.0001). There were six procedural complications (1%). Two were unequivocally related to coronary angiography: one minor stroke (diplopia), and one iatrogenic dissection of the right coronary ostium requiring stenting. Furthermore, four arteriovenous fistulae at the puncture site requiring elective surgical closure were possibly related to coronary angiography. Forty-five patients (8% of total) underwent percutaneous (n = 43) or surgical (n = 2) revascularization. In selected asymptomatic patients referred for percutaneous PFO closure, incidental coronary angiography discloses a rather high prevalence of clinically unsuspected CAD. These findings are relevant not only for timely revascularization but also for maintenance of long-term antiplatelet therapy beyond the few months recommended after PFO closure. (c) 2007 Wiley-Liss, Inc.

  3. Multicenter Evaluation Of Coronary Dual-Source CT angiography in patients with intermediate Risk of Coronary Artery Stenoses (MEDIC): study design and rationale.

    PubMed

    Marwan, Mohamed; Hausleiter, Jörg; Abbara, Suhny; Hoffmann, Udo; Becker, Christoph; Ovrehus, Kristian; Ropers, Dieter; Bathina, Ravi; Berman, Dan; Anders, Katharina; Uder, Michael; Meave, Aloha; Alexánderson, Erick; Achenbach, Stephan

    2014-01-01

    The diagnostic performance of multidetector row CT to detect coronary artery stenosis has been evaluated in numerous single-center studies, with only limited data from large cohorts with low-to-intermediate likelihood of coronary disease and in multicenter trials. The Multicenter Evaluation of Coronary Dual-Source CT Angiography in Patients with Intermediate Risk of Coronary Artery Stenoses (MEDIC) trial determines the accuracy of dual-source CT (DSCT) to identify persons with at least 1 coronary artery stenosis among patients with low-to-intermediate pretest likelihood of disease. The MEDIC trial was designed as a prospective, multicenter, international trial to evaluate the diagnostic performance of DSCT for the detection of coronary artery stenosis compared with invasive coronary angiography. The study includes 8 sites in Germany, India, Mexico, the United States, and Denmark. The study population comprises patients referred for a diagnostic coronary angiogram because of suspected coronary artery disease with an intermediate pretest likelihood as determined by sex, age, and symptoms. All evaluations are performed by blinded core laboratory readers. The primary outcome of the MEDIC trial is the accuracy of DSCT to identify the presence of coronary artery stenoses with a luminal diameter narrowing of 50% or more on a per-vessel basis. Secondary outcome parameters include per-patient and per-segment diagnostic accuracy for 50% stenoses and accuracy to identify stenoses of 70% or more. Furthermore, secondary outcome parameters include the influence of heart rate, Agatston score, body weight, body mass index, image quality, and diagnostic confidence on the accuracy to detect coronary artery stenoses >50% on a per-vessel basis. The results of the MEDIC trial will assess the clinical utility of coronary CT angiography in the evaluation of patients with intermediate pretest likelihood of coronary artery disease. Copyright © 2014 Society of Cardiovascular Computed

  4. Nationwide trends in use and timeliness of diagnostic coronary angiography in acute coronary syndromes from 2005 to 2011: Does distance to invasive heart centres matter?

    PubMed

    Hansen, Kim W; Sørensen, Rikke; Madsen, Mette; Madsen, Jan K; Jensen, Jan S; von Kappelgaard, Lene M; Mortensen, Poul E; Galatius, Søren

    2015-08-01

    To examine trends in the use of diagnostic coronary angiography according to distance from home to the nearest invasive heart centre following implementation of fast-track protocols and extensive pre-hospital triaging of acute coronary syndrome patients. We performed a register-based cohort study of all patients admitted to Danish hospitals with incident acute coronary syndrome in 2005-2011. Diagnostic coronary angiography within 60 days of admission was investigated according to distance tertiles (DTs) calculated as range from each patient's home to the nearest invasive heart centre (short DT: <22 km, medium DT: 22-65 km, long DT: >65 km). Cox proportional hazards models were applied.Among the 52,409 patients included, diagnostic coronary angiography was increasingly used during 2005-2011 (short DT: 76% to 81%; medium DT: 74% to 81%; long DT: 69% to 78%; all p-values for trend <0.001). Using the short DT as reference the adjusted hazard ratios for medium DT were 0.87 (0.84-0.89) for 2005-2007, 0.94 (0.90-0.98) for 2008-2009 and 0.94 (0.90-0.98) for 2010-2011. Corresponding figures for long DT were 0.74 (0.72-0.76) for 2005-2007, 0.87 (0.83-0.90) for 2008-2009 and 0.94 (0.90-0.98) for 2010-2011. Length of hospital stay, time to coronary angiography, and 60-day mortality decreased in all DT. This nationwide study found significant increases in diagnostic coronary angiography use over time in incident acute coronary syndrome patients with a relatively larger increase in patients residing farthest from an invasive heart centre. Additionally, selected quality of care measures improved in the entire cohort, suggesting a benefit of national clinical protocols. © The European Society of Cardiology 2014.

  5. Evaluation of computed tomography in patients with atypical angina or chest pain clinically referred for invasive coronary angiography: randomised controlled trial

    PubMed Central

    Rief, Matthias; Martus, Peter; Kendziora, Benjamin; Feger, Sarah; Dreger, Henryk; Priem, Sascha; Knebel, Fabian; Böhm, Marko; Schlattmann, Peter; Hamm, Bernd; Schönenberger, Eva; Laule, Michael; Zimmermann, Elke

    2016-01-01

    Objective To evaluate whether invasive coronary angiography or computed tomography (CT) should be performed in patients clinically referred for coronary angiography with an intermediate probability of coronary artery disease. Design Prospective randomised single centre trial. Setting University hospital in Germany. Participants 340 patients with suspected coronary artery disease and a clinical indication for coronary angiography on the basis of atypical angina or chest pain. Interventions 168 patients were randomised to CT and 172 to coronary angiography. After randomisation one patient declined CT and 10 patients declined coronary angiography, leaving 167 patients (88 women) and 162 patients (78 women) for analysis. Allocation could not be blinded, but blinded independent investigators assessed outcomes. Main outcome measure The primary outcome measure was major procedural complications within 48 hours of the last procedure related to CT or angiography. Results Cardiac CT reduced the need for coronary angiography from 100% to 14% (95% confidence interval 9% to 20%, P<0.001) and was associated with a significantly greater diagnostic yield from coronary angiography: 75% (53% to 90%) v 15% (10% to 22%), P<0.001. Major procedural complications were uncommon (0.3%) and similar across groups. Minor procedural complications were less common in the CT group than in the coronary angiography group: 3.6% (1% to 8%) v 10.5% (6% to 16%), P=0.014. CT shortened the median length of stay in the angiography group from 52.9 hours (interquartile range 49.5-76.4 hours) to 30.0 hours (3.5-77.3 hours, P<0.001). Overall median exposure to radiation was similar between the CT and angiography groups: 5.0 mSv (interquartile range 4.2-8.7 mSv) v 6.4 mSv (3.4-10.7 mSv), P=0.45. After a median follow-up of 3.3 years, major adverse cardiovascular events had occurred in seven of 167 patients in the CT group (4.2%) and six of 162 (3.7%) in the coronary angiography group (adjusted hazard

  6. Waiting for coronary angiography: is there a clinically ordered queue?

    PubMed

    Hemingway, H; Crook, A M; Feder, G; Dawson, J R; Timmis, A

    2000-03-18

    Among over 3000 patients undergoing coronary angiography in the absence of a formal queue-management system, we found that a-priori urgency scores were strongly associated with waiting times, prevalence of coronary-artery disease, rate of revascularisation, and mortality. These data challenge the widely held assumption that such waiting lists are not clinically ordered; however, the wide variation in waiting times within urgency categories suggests the need for further improvements in clinical queueing.

  7. Atherosclerosis and Liver Function Tests in Coronary Angiography Patients.

    PubMed

    Doganer, Y C; Rohrer, J E; Aydogan, U; Agerter, D C; Cayci, T; Barcin, C

    2015-09-01

    Elevated aminotransferase levels indicating liver function, even in the normal range, have attracted great concern as potential novel markers of cardiovascular risk assessment. We hypothesized the possibility that liver function test variations in the normal range might be meaningfully associated to coronary artery disease (CAD). Eighty-eight patients were randomly selected from those who underwent coronary angiography from June 2010 to June 2011 after applying to the outpatient cardiology clinic in Gulhane Military Medical Academy. According to the results of angiographies, patients were classified into three groups as normal, non-critical (< 50% involvement in coronaries), and critical (≥ 50% involvement in coronaries). In addition to angiographic intervention, measurements of serum aspartate aminotransferase (AST) and alanine aminotransferase (ALT) concentrations, albumin and the other serum parameters were performed in all patients. The patient groups of CAD were balanced (28 critical cases, 30 non-critical cases and 30 normal cases). Mean age was 51.93 ± 9.3 (range 32-65) years and 19.3 per cent (n = 17) were females. Multiple linear regression analysis of all three liver function tests explained a significant portion of the variance, but adjusted r-squares were small (AST = 0.174, ALT = 0.242, albumin = 0.124). Albumin was significantly higher for patients with critical CAD than for patients with no CAD (beta = 3.205, p = 0.002). Non-critical CAD was not significantly different from no CAD for any of the dependent variables. Mean AST was significantly higher for patients taking aspirin (beta = 0.218, p = 0.049), as was mean ALT (beta = 0.264, p = 0.015). Alanine aminotransferase and AST may not be associated with angiographically determined coronary atherosclerosis. Albumin may be more sensitive to demonstrate the burden of atherosclerosis. These results indicate that the association between the liver function tests and coronary atherosclerosis may be more

  8. Non-invasive coronary angiography for patients with acute atypical chest pain discharged after negative screening including maximal negative treadmill stress test. A prospective study.

    PubMed

    Bonello, L; Armero, S; Jacquier, A; Com, O; Sarran, A; Sbragia, P; Panuel, M; Arques, S; Paganelli, F

    2009-05-01

    Among patients admitted in the emergency department for acute atypical chest pain those with an acute coronary syndrome (ACS) who are mistakenly discharged home have high mortality. A recent retrospective study has demonstrated that multislice computed tomography (MSCT) coronary angiography could improve triage of these patients. We aimed to prospectively confirm these data on patients with a negative screening including maximal treadmill stress. 30 patients discharged from the emergency department after negative screening for an ACS were included. All patients underwent MSCT angiography of the coronary artery. Patients with coronary atheroma on MSCT had an invasive coronary angiography to confirm these findings. Seven patients (23%) had obstructive coronary artery disease on MSCT. Invasive coronary angiography (ICA) confirmed the diagnosis in all patients. In patients with no previously known coronary artery disease admitted to the emergency department with atypical acute chest pain and discharged after negative screening, including maximal treadmill stress test, MSCT coronary angiography is useful for the diagnosis of obstructive coronary artery disease.

  9. Coronary artery calcium score and CT angiography in asymptomatic elderly patients with high pretest probability for coronary artery disease.

    PubMed

    Imanzadeh, Amir; George, Elizabeth; Kondo, Takeshi; Takase, Shinichi; Amanuma, Makoto; Rybicki, Frank J; Kumamaru, Kanako K

    2016-02-01

    To evaluate the role of coronary artery calcium scoring (CACS) and/or coronary CT angiography (CCTA) in asymptomatic elderly patients with high pretest probability for coronary artery disease (CAD). Forty-eight consecutive asymptomatic elderly (>65 years) subjects who had a high pretest probability and underwent CACS/CCTA were included. Each CCTA was evaluated for adequacy for assessment of coronary stenosis. Significant stenosis (>50% diameter narrowing) was assessed on evaluable CT images and by invasive catheter angiography (ICA). All subjects were men with mean CACS of 880 ± 1779. Among those with low (0-99), intermediate (100-399), and high (400-999) CACS, ICA-verified significant stenosis was present in 8% (1/13), 23% (2/13), and 67% (8/12), respectively. Among those with very high CACS (≥ 1000) (n = 10), 90% of CCTAs were not evaluable for stenosis. In asymptomatic elderly subjects with high pretest probability, CACS followed by CCTA may be considered for those with intermediate to high CACS.

  10. K-edge subtraction synchrotron X-ray imaging in bio-medical research.

    PubMed

    Thomlinson, W; Elleaume, H; Porra, L; Suortti, P

    2018-05-01

    High contrast in X-ray medical imaging, while maintaining acceptable radiation dose levels to the patient, has long been a goal. One of the most promising methods is that of K-edge subtraction imaging. This technique, first advanced as long ago as 1953 by B. Jacobson, uses the large difference in the absorption coefficient of elements at energies above and below the K-edge. Two images, one taken above the edge and one below the edge, are subtracted leaving, ideally, only the image of the distribution of the target element. This paper reviews the development of the KES techniques and technology as applied to bio-medical imaging from the early low-power tube sources of X-rays to the latest high-power synchrotron sources. Applications to coronary angiography, functional lung imaging and bone growth are highlighted. A vision of possible imaging with new compact sources is presented. Copyright © 2018 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  11. Evaluation of computed tomography in patients with atypical angina or chest pain clinically referred for invasive coronary angiography: randomised controlled trial.

    PubMed

    Dewey, Marc; Rief, Matthias; Martus, Peter; Kendziora, Benjamin; Feger, Sarah; Dreger, Henryk; Priem, Sascha; Knebel, Fabian; Böhm, Marko; Schlattmann, Peter; Hamm, Bernd; Schönenberger, Eva; Laule, Michael; Zimmermann, Elke

    2016-10-24

     To evaluate whether invasive coronary angiography or computed tomography (CT) should be performed in patients clinically referred for coronary angiography with an intermediate probability of coronary artery disease.  Prospective randomised single centre trial.  University hospital in Germany.  340 patients with suspected coronary artery disease and a clinical indication for coronary angiography on the basis of atypical angina or chest pain.  168 patients were randomised to CT and 172 to coronary angiography. After randomisation one patient declined CT and 10 patients declined coronary angiography, leaving 167 patients (88 women) and 162 patients (78 women) for analysis. Allocation could not be blinded, but blinded independent investigators assessed outcomes.  The primary outcome measure was major procedural complications within 48 hours of the last procedure related to CT or angiography.  Cardiac CT reduced the need for coronary angiography from 100% to 14% (95% confidence interval 9% to 20%, P<0.001) and was associated with a significantly greater diagnostic yield from coronary angiography: 75% (53% to 90%) v 15% (10% to 22%), P<0.001. Major procedural complications were uncommon (0.3%) and similar across groups. Minor procedural complications were less common in the CT group than in the coronary angiography group: 3.6% (1% to 8%) v 10.5% (6% to 16%), P=0.014. CT shortened the median length of stay in the angiography group from 52.9 hours (interquartile range 49.5-76.4 hours) to 30.0 hours (3.5-77.3 hours, P<0.001). Overall median exposure to radiation was similar between the CT and angiography groups: 5.0 mSv (interquartile range 4.2-8.7 mSv) v 6.4 mSv (3.4-10.7 mSv), P=0.45. After a median follow-up of 3.3 years, major adverse cardiovascular events had occurred in seven of 167 patients in the CT group (4.2%) and six of 162 (3.7%) in the coronary angiography group (adjusted hazard ratio 0.90, 95% confidence interval 0.30 to 2.69, P=0.86). 79% of patients

  12. Chamber dimensions and functional assessment with coronary computed tomographic angiography as compared to echocardiography using American Society of Echocardiography guidelines

    PubMed Central

    Rose, Michael; Rubal, Bernard; Hulten, Edward; Slim, Jennifer N; Steel, Kevin; Furgerson, James L; Villines, Todd C

    2014-01-01

    Background: The correlation between normal cardiac chamber linear dimensions measured during retrospective coronary computed tomographic angiography as compared to transthoracic echocardiography using the American Society of Echocardiography guidelines is not well established. Methods: We performed a review from January 2005 to July 2011 to identify subjects with retrospective electrocardiogram-gated coronary computed tomographic angiography scans for chest pain and transthoracic echocardiography with normal cardiac structures performed within 90 days. Dimensions were manually calculated in both imaging modalities in accordance with the American Society of Echocardiography published guidelines. Left ventricular ejection fraction was calculated on echocardiography manually using the Simpson’s formula and by coronary computed tomographic angiography using the end-systolic and end-diastolic volumes. Results: We reviewed 532 studies, rejected 412 and had 120 cases for review with a median time between studies of 7 days (interquartile range (IQR25,75) = 0–22 days) with no correlation between the measurements made by coronary computed tomographic angiography and transthoracic echocardiography using Bland–Altman analysis. We generated coronary computed tomographic angiography cardiac dimension reference ranges for both genders for our population. Conclusion: Our findings represent a step towards generating cardiac chamber dimensions’ reference ranges for coronary computed tomographic angiography as compared to transthoracic echocardiography in patients with normal cardiac morphology and function using the American Society of Echocardiography guideline measurements that are commonly used by cardiologists. PMID:26770706

  13. K-edge Subtraction Angiography with Synchrotron X-Rays: Final Technical Report, (February 1, 1984 to January 31, 1987)

    DOE R&D Accomplishments Database

    Hofstadter, R.

    1987-09-01

    The aim was the development of an angiographic method and appropriate equipment for imaging with x-rays the coronary arteries in a non-invasive manner. Successive steps involved studies with phantoms, live animals and finally with human subjects. Clinical evaluation of human coronary arteries remains a goal of this and a continuing project, and steps along the way to such an achievement are in process. Transvenous injection of a dye using the method of iodine dichromography near 33.2 keV, the K-edge of iodine, forms the basis of the method

  14. Acute Fulminant Uremic Neuropathy Following Coronary Angiography Mimicking Guillain-Barre Syndrome.

    PubMed

    Priti, Kumari; Ranwa, Bhanwar

    2017-01-01

    A 55-year-old diabetic woman suffered a posterior wall ST-elevation myocardial infarction. She developed contrast-induced nephropathy following coronary angiography. Acute fulminant uremic neuropathy was precipitated which initially mimicked Guillan-Barre Syndrome, hence reported.

  15. Long-term results of a randomized controlled trial analyzing the role of systematic pre-operative coronary angiography before elective carotid endarterectomy in patients with asymptomatic coronary artery disease.

    PubMed

    Illuminati, G; Schneider, F; Greco, C; Mangieri, E; Schiariti, M; Tanzilli, G; Barillà, F; Paravati, V; Pizzardi, G; Calio', F; Miraldi, F; Macrina, F; Totaro, M; Greco, E; Mazzesi, G; Tritapepe, L; Toscano, M; Vietri, F; Meyer, N; Ricco, J-B

    2015-04-01

    To evaluate the potential benefit of systematic preoperative coronary-artery angiography followed by selective coronary-artery revascularization on the incidence of myocardial infarction (MI) in patients undergoing carotid endarterectomy (CEA) without a previous history of coronary artery disease (CAD). We randomised 426 patients who were candidates for CEA, with no history of CAD, a normal electrocardiogram (ECG), and a normal cardiac ultrasound. In group A (n = 216) all patients underwent coronary angiography before CEA. In group B (n = 210) CEA was performed without coronary angiography. Patients were not blinded for relevant assessments during follow-up. Primary end-point was the occurrence of MI at 3.5 years. The secondary end-point was the overall survival rate. Median length of follow-up was 6.2 years. In group A, coronary angiography revealed significant coronary artery stenosis in 68 patients (31.5%). Among them, 66 underwent percutaneous Intervention (PCI) prior to CEA and 2 received combined CEA and coronary-artery bypass grafting (CABG). Postoperatively, no MI was observed in group A, whereas 6 MI occurred in group B, one of which was fatal (p = .01). During the study period, 3 MI occurred in group A (1.4%) and 33 were observed in group B (15.7%), 6 of which were fatal. The Cox model demonstrated a reduced risk of MI for patients in group A receiving coronary angiography (HR,.078; 95% CI, 0.024-0.256; p < .001). In addition, patients with diabetes and patients <70 years presented with an increased risk of MI. Survival analysis at 6 years by Kaplan-Meier estimates was 95.6 ± 3.2% in Group A and 89.7 ± 3.7% in group B (Log Rank = 6.54, p = .01). In asymptomatic coronary-artery patients, systematic coronary angiography prior to CEA followed by selective PCI or CABG significantly reduces the incidence of late MI and increases long-term survival. (ClinicalTrials.gov number, NCT02260453). Copyright © 2015 European Society for Vascular

  16. Urinary KIM-1, NGAL and L-FABP for the diagnosis of AKI in patients with acute coronary syndrome or heart failure undergoing coronary angiography.

    PubMed

    Torregrosa, Isidro; Montoliu, Carmina; Urios, Amparo; Andrés-Costa, María Jesús; Giménez-Garzó, Carla; Juan, Isabel; Puchades, María Jesús; Blasco, María Luisa; Carratalá, Arturo; Sanjuán, Rafael; Miguel, Alfonso

    2015-11-01

    Acute kidney injury (AKI) is a common complication after coronary angiography. Early biomarkers of this disease are needed since increase in serum creatinine levels is a late marker. To assess the usefulness of urinary kidney injury molecule-1 (uKIM-1), neutrophil gelatinase-associated lipocalin (uNGAL) and liver-type fatty acid-binding protein (uL-FABP) for early detection of AKI in these patients, comparing their performance with another group of cardiac surgery patients. Biomarkers were measured in 193 patients, 12 h after intervention. In the ROC analysis, AUC for KIM-1, NGAL and L-FABP was 0.713, 0.958 and 0.642, respectively, in the coronary angiography group, and 0.716, 0.916 and 0.743 in the cardiac surgery group. Urinary KIM-1 12 h after intervention is predictive of AKI in adult patients undergoing coronary angiography, but NGAL shows higher sensitivity and specificity. L-FABP provides inferior discrimination for AKI than KIM-1 or NGAL in contrast to its performance after cardiac surgery. This is the first study showing the predictive capacity of KIM-1 for AKI after coronary angiography. Further studies are still needed to answer relevant questions about the clinical utility of biomarkers for AKI in different clinical settings.

  17. Subarachnoid Hemorrhage Mimicking Leakage of Contrast Media After Coronary Angiography

    PubMed Central

    Oh, Min Seok; Kwon, Jee Eun; Kim, Kyung Jun; Jo, Joon Hwan; Min, Yun Ju; Byun, Jun Soo; Kim, Kyung Tae; Kim, Sang Wook

    2012-01-01

    We report a patient who developed subarachnoid hemorrhage (SAH) just after coronary angiography (CAG) with non-ionic contrast media (CM) and minimal dose of heparin. The 55-year-old man had a history of acute ST elevation myocardial infarction that had been treated with primary percutaneous coronary intervention and was admitted for a follow-up CAG. The CAG was performed by the transradial approach, using 1000 U of unfractionated heparin for the luminal coating and 70 mL of iodixanol. At the end of CAG, he complained of nausea and rapidly became stuporous. Brain CT showed a diffusely increased Hounsfield unit (HU) in the cisternal space, similar to leakage of CM. The maximal HU was 65 in the cisternal space. No vascular malformations were detected on cerebral angiography. The patient partially recovered his mental status and motor weakness after 2 days. Two weeks later, subacute SAH was evident on magnetic resonance imaging. The patient was discharged after 28 days. PMID:22493615

  18. CT Coronary Angiography vs. Coronary Artery Calcium Scoring for the Occupational Assessment of Military Aircrew.

    PubMed

    Parsons, Iain; Pavitt, Chris; Chamley, Rebecca; d'Arcy, Jo; Nicol, Ed

    2017-02-01

    To ensure flight safety military aircrew undergo regular clinical and occupational assessment. Coronary artery calcium scoring (CACS) has been established as an imaging modality to noninvasively assess coronary artery disease (CAD). CT coronary angiography (CTCA) potentially offers a more accurate assessment of CAD, but has not been formally assessed in military aircrew. This retrospective cohort study is designed to compare the theoretical differences in downstream investigations and occupational outcomes in aircrew with suspected CAD comparing CTCA with existing CACS pathways. A 2-yr retrospective cohort study of consecutive UK military patients who underwent a CTCA and CACS was undertaken. Patient demographics, CTCA and CACS results, and initial and final occupational restrictions were analyzed comparing current UK, Canadian, and U.S. pathways. There were 44 patients who underwent CACS and CTCA. The commonest indication for a CTCA was a positive exercise ECG. Increasing CACS, stenosis severity, and stenosis burden were associated with significantly greater likelihood of occupational restriction (P = < 0.01). Following CTCA, 26/44 (59%) patients were found to have evidence of CAD, with 13/44 (30%) having at least a single vessel stenosis ≥50%. All of these patients had subsequent occupational restrictions. Two patients with a calcium score ≤10 had at least 1 single vessel stenosis ≥50%. A CTCA pathway is potentially a better discriminator of CAD burden in aircrew when compared with CACS and may reduce downstream testing, allowing a more efficacious approach to CAD assessment in military aircrew.Parsons I, Pavitt C, Chamley R, d'Arcy J, Nicol E. CT coronary angiography vs. coronary artery calcium scoring for the occupational assessment of military aircrew. Aerosp Med Hum Perform. 2017; 88(2):76-81.

  19. Acute Fulminant Uremic Neuropathy Following Coronary Angiography Mimicking Guillain–Barre Syndrome

    PubMed Central

    Priti, Kumari; Ranwa, Bhanwar

    2017-01-01

    A 55-year-old diabetic woman suffered a posterior wall ST-elevation myocardial infarction. She developed contrast-induced nephropathy following coronary angiography. Acute fulminant uremic neuropathy was precipitated which initially mimicked Guillan–Barre Syndrome, hence reported. PMID:28706599

  20. [Development of an automated processing method to detect coronary motion for coronary magnetic resonance angiography].

    PubMed

    Asou, Hiroya; Imada, N; Sato, T

    2010-06-20

    On coronary MR angiography (CMRA), cardiac motions worsen the image quality. To improve the image quality, detection of cardiac especially for individual coronary motion is very important. Usually, scan delay and duration were determined manually by the operator. We developed a new evaluation method to calculate static time of individual coronary artery. At first, coronary cine MRI was taken at the level of about 3 cm below the aortic valve (80 images/R-R). Chronological change of the signals were evaluated with Fourier transformation of each pixel of the images were done. Noise reduction with subtraction process and extraction process were done. To extract higher motion such as coronary arteries, morphological filter process and labeling process were added. Using these imaging processes, individual coronary motion was extracted and individual coronary static time was calculated automatically. We compared the images with ordinary manual method and new automated method in 10 healthy volunteers. Coronary static times were calculated with our method. Calculated coronary static time was shorter than that of ordinary manual method. And scan time became about 10% longer than that of ordinary method. Image qualities were improved in our method. Our automated detection method for coronary static time with chronological Fourier transformation has a potential to improve the image quality of CMRA and easy processing.

  1. Optimization of coronary attenuation in coronary computed tomography angiography using diluted contrast material.

    PubMed

    Kawaguchi, Naoto; Kurata, Akira; Kido, Teruhito; Nishiyama, Yoshiko; Kido, Tomoyuki; Miyagawa, Masao; Ogimoto, Akiyoshi; Mochizuki, Teruhito

    2014-01-01

    The purpose of this study was to evaluate a personalized protocol with diluted contrast material (CM) for coronary computed tomography angiography (CTA). One hundred patients with suspected coronary artery disease underwent retrospective electrocardiogram-gated coronary CTA on a 256-slice multidetector-row CT scanner. In the diluted CM protocol (n=50), the optimal scan timing and CM dilution rate were determined by the timing bolus scan, with 20% CM dilution (5ml/s during 10s) being considered suitable to achieve the target arterial attenuation of 350 Hounsfield units (HU). In the body weight (BW)-adjusted protocol (n=50, 222mg iodine/kg), only the optimal scan timing was determined by the timing bolus scan. The injection rate and volume in the timing bolus scan and real scan were identical between the 2 protocols. We compared the means and variations in coronary attenuation between the 2 protocols. Coronary attenuation (mean±SD) in the diluted CM and BW-adjusted protocols was 346.1±23.9 HU and 298.8±45.2 HU, respectively. The diluted CM protocol provided significantly higher coronary attenuation and lower variance than did the BW-adjusted protocol (P<0.05, in each). The diluted CM protocol facilitates more uniform attenuation on coronary CTA in comparison with the BW-adjusted protocol.  

  2. Motion-corrected whole-heart PET-MR for the simultaneous visualisation of coronary artery integrity and myocardial viability: an initial clinical validation.

    PubMed

    Munoz, Camila; Kunze, Karl P; Neji, Radhouene; Vitadello, Teresa; Rischpler, Christoph; Botnar, René M; Nekolla, Stephan G; Prieto, Claudia

    2018-05-12

    Cardiac PET-MR has shown potential for the comprehensive assessment of coronary heart disease. However, image degradation due to physiological motion remains a challenge that could hinder the adoption of this technology in clinical practice. The purpose of this study was to validate a recently proposed respiratory motion-corrected PET-MR framework for the simultaneous visualisation of myocardial viability ( 18 F-FDG PET) and coronary artery anatomy (coronary MR angiography, CMRA) in patients with chronic total occlusion (CTO). A cohort of 14 patients was scanned with the proposed PET-CMRA framework. PET and CMRA images were reconstructed with and without the proposed motion correction approach for comparison purposes. Metrics of image quality including visible vessel length and sharpness were obtained for CMRA for both the right and left anterior descending coronary arteries (RCA, LAD), and relative increase in 18 F-FDG PET signal after motion correction for standard 17-segment polar maps was computed. Resulting coronary anatomy by CMRA and myocardial integrity by PET were visually compared against X-ray angiography and conventional Late Gadolinium Enhancement (LGE) MRI, respectively. Motion correction increased CMRA visible vessel length by 49.9% and 32.6% (RCA, LAD) and vessel sharpness by 12.3% and 18.9% (RCA, LAD) on average compared to uncorrected images. Coronary lumen delineation on motion-corrected CMRA images was in good agreement with X-ray angiography findings. For PET, motion correction resulted in an average 8% increase in 18 F-FDG signal in the inferior and inferolateral segments of the myocardial wall. An improved delineation of myocardial viability defects and reduced noise in the 18 F-FDG PET images was observed, improving correspondence to subendocardial LGE-MRI findings compared to uncorrected images. The feasibility of the PET-CMRA framework for simultaneous cardiac PET-MR imaging in a short and predictable scan time (~11 min) has been

  3. Automatic coronary artery segmentation based on multi-domains remapping and quantile regression in angiographies.

    PubMed

    Li, Zhixun; Zhang, Yingtao; Gong, Huiling; Li, Weimin; Tang, Xianglong

    2016-12-01

    Coronary artery disease has become the most dangerous diseases to human life. And coronary artery segmentation is the basis of computer aided diagnosis and analysis. Existing segmentation methods are difficult to handle the complex vascular texture due to the projective nature in conventional coronary angiography. Due to large amount of data and complex vascular shapes, any manual annotation has become increasingly unrealistic. A fully automatic segmentation method is necessary in clinic practice. In this work, we study a method based on reliable boundaries via multi-domains remapping and robust discrepancy correction via distance balance and quantile regression for automatic coronary artery segmentation of angiography images. The proposed method can not only segment overlapping vascular structures robustly, but also achieve good performance in low contrast regions. The effectiveness of our approach is demonstrated on a variety of coronary blood vessels compared with the existing methods. The overall segmentation performances si, fnvf, fvpf and tpvf were 95.135%, 3.733%, 6.113%, 96.268%, respectively. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. Acetylcholine test in patients with angina pectoris and normal coronary angiography

    NASA Astrophysics Data System (ADS)

    Barbieri, Enrico; Destro, Gianni; Oliva, Massimo; Zardini, Piero

    1994-02-01

    Angina pectoris with normal coronary artery on the coronary angiography is an intriguing issue. Intracoronary infusion of acetylcholine has recently been used to test the integrity of endothelial cells. We studied 16 patients with this syndrome. A relationship has been found between the acetylcholine test and the exercise stress test in normotensive patients. The presence of hypertension makes the evaluation of the test more unpredictable, probably because of the damage on the endothelial cells related to systemic hypertension.

  5. Coronary Computed Tomographic Angiography-Derived Fractional Flow Reserve for Therapeutic Decision Making.

    PubMed

    Tesche, Christian; Vliegenthart, Rozemarijn; Duguay, Taylor M; De Cecco, Carlo N; Albrecht, Moritz H; De Santis, Domenico; Langenbach, Marcel C; Varga-Szemes, Akos; Jacobs, Brian E; Jochheim, David; Baquet, Moritz; Bayer, Richard R; Litwin, Sheldon E; Hoffmann, Ellen; Steinberg, Daniel H; Schoepf, U Joseph

    2017-12-15

    This study investigated the performance of coronary computed tomography angiography (cCTA) with cCTA-derived fractional flow reserve (CT-FFR) compared with invasive coronary angiography (ICA) with fractional flow reserve (FFR) for therapeutic decision making in patients with suspected coronary artery disease (CAD). Seventy-four patients (62 ± 11 years, 62% men) with at least 1 coronary stenosis of ≥50% on clinically indicated dual-source cCTA, who had subsequently undergone ICA with FFR measurement, were retrospectively evaluated. CT-FFR values were computed using an on-site machine-learning algorithm to assess the functional significance of CAD. The therapeutic strategy (optimal medical therapy alone vs revascularization) and the appropriate revascularization procedure (percutaneous coronary intervention vs coronary artery bypass grafting) were selected using cCTA-CT-FFR. Thirty-six patients (49%) had a functionally significant CAD based on ICA-FFR. cCTA-CT-FFR correctly identified a functionally significant CAD and the need of revascularization in 35 of 36 patients (97%). When revascularization was deemed indicated, the same revascularization procedure (32 percutaneous coronary interventions and 3 coronary artery bypass grafting) was chosen in 35 of 35 patients (100%). Overall, identical management strategies were selected in 73 of the 74 patients (99%). cCTA-CT-FFR shows excellent performance to identify patients with and without the need for revascularization and to select the appropriate revascularization strategy. cCTA-CT-FFR as a noninvasive "one-stop shop" has the potential to change diagnostic workflows and to directly inform therapeutic decision making in patients with suspected CAD. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Incidence and predictors of silent embolic cerebral infarction following diagnostic coronary angiography.

    PubMed

    Kim, In-Cheol; Hur, Seung-Ho; Park, Nam-Hee; Jun, Dong-Hwan; Cho, Yun-Kyeong; Nam, Chang-Wook; Kim, Hyungseop; Han, Seong-Wook; Choi, Sae-Young; Kim, Yoon-Nyun; Kim, Kwon-Bae

    2011-04-14

    Coronary angiography (CAG) is an invasive diagnostic procedure, which could lead to procedure related complications. One of the well known post-procedural complications is cerebral embolic infarction with or without symptoms. Silent embolic cerebral infarction (SECI) has clinical significance because it can progress to a decline in cognitive function and increase the risk of dementia in the long term. The aim of this study was to detect the incidence and predictors of SECI after diagnostic CAG using diffusion-weighted magnetic resonance imaging (DW-MRI). A total of 197 patients with coronary artery disease who underwent DW-MRI for evaluation of intracranial vasculopathy before coronary artery bypass graft surgery were retrospectively enrolled in the present study. DW-MRI was performed within 48 h after diagnostic CAG. SECI was diagnosed as presence of focal bright high signal intensity in DW-MRI. Patients were divided into groups according to presence/absence of SECI (+ SECI vs. - SECI, respectively). The clinical and angiographic characteristics were analyzed and independent predictors were evaluated. Of the 197 patients, SECI occurred in 20 patients (10.2%) after diagnostic CAG. Age, female gender, frequency of underlying atrial fibrillation, extent of coronary disease, and fluoroscopic time during diagnostic CAG were not different between the + SECI and - SECI groups. Left ventricular ejection fraction was significantly lower in the + SECI group than in the - SECI group (45.9 ± 8.5% vs. 51.4 ± 13.1%, p=0.014) and performance rate of internal mammary artery (IMA) angiography was significantly higher in the + SECI group compared with the - SECI group (85% vs. 37.2%, p<0.001). By multivariate analysis, performing IMA angiography was the only predictor of SECI (OR=14.642; 95% CI=3.201 to 66.980, p=0.001). The incidence of SECI after diagnostic CAG was not infrequent. Diagnostic CAG with IMA angiography may increase the risk of SECI. Copyright © 2009 Elsevier

  7. PROMISE of Coronary CT Angiography: Precise and Accurate Diagnosis and Prognosis in Coronary Artery Disease.

    PubMed

    Thomas, Dustin M; Branch, Kelley R; Cury, Ricardo C

    2016-04-01

    Coronary computed tomography angiography (CCTA) is a rapidly growing and powerful diagnostic test that offers a great deal of precision with respect to diagnosing coronary artery disease (CAD). Guideline statements for patients with stable ischemic heart disease have recommended CCTA for only a limited portion of intermediate-risk patients who have relative or absolute contraindications for exercise or vasodilator stress testing. The publication of two large, prospective randomized clinical trials, the Prospective Multicenter Imaging Study for Evaluation of Chest Pain and the Scottish Computed Tomography of the Heart Trial are likely to expand these indications. These new data from large trials, in addition to other studies, show that CCTA is highly sensitive for the detection of CAD, identifies high-risk patients for cardiac events based on extent or plaque morphology of CAD that would not be identified by other noninvasive means, and provides significantly greater diagnostic certainty for proper treatment, including referral for invasive coronary angiography with revascularization more appropriately. Superior diagnostic accuracy and prognostic data with CCTA, when compared with other functional stress tests, may result in a reduction in unnecessary downstream testing and cost savings. In addition, newer CCTA applications hold the promise of providing a complete evaluation of a patient's coronary anatomy as well as a per-vessel ischemic evaluation. This review focuses on the interval knowledge obtained from newer data on CCTA in patients with stable ischemic heart disease, primarily focusing on the contributions of the Prospective Multicenter Imaging Study for Evaluation of Chest Pain and the Scottish Computed Tomography of the Heart Trial.

  8. Coronary In-Stent Restenosis: Assessment with Corrected Coronary Opacification Difference across Coronary Stents Measured with CT Angiography.

    PubMed

    Gao, Yang; Lu, Bin; Hou, Zhi Hui; Yu, Fang Fang; Yin, Wei Hua; Wang, Zhi Qiang; Wu, Yong Jian; Mu, Chao Wei; Meinel, Felix G; McQuiston, Andrew D; Schoepf, U Joseph

    2015-05-01

    To determine whether changes in coronary opacification normalized to the aorta (corrected coronary opacification [CCO]) across stents can help identify in-stent restenosis (ISR) severity with use of invasive coronary angiography as the standard of reference. This study was approved by the institutional review board, and the requirement to obtain informed consent was waived. The authors retrospectively analyzed 106 patients (88 men, 18 women; mean age, 59.6 years ± 10.4; age range, 36-84 years) who had previously undergone stent implantation within 3 months of coronary computed tomographic (CT) angiography. Attenuation values in the coronary lumen were measured proximal and distal to the stents and normalized to the descending aorta. The CCO difference across the stent was compared with the severity of ISR. One-way analysis of variance least significant difference was used for comparison. A total of 141 stents were assessed. Seventy-six stents were normally patent, 18 had ISR of less than 50%, 28 had ISR of 50%-99%, and 19 were fully occluded. The median CCO differences in the four groups were 0.078, 0.163, 0.346, and 0.606, respectively. There was no significant difference between stents with an ISR of at least 50% and those with total occlusion (P = .056), although the other groups had significant differences at pairwise comparison (P < .01 for all). For stents smaller than 3 mm in diameter, the median CCO differences in the four groups were 0.086, 0.136, 0.390, and 0.471, respectively. The CCO differences across normal stents and stents with ISR of less than 50% were significantly less than those across stents with an ISR of at least 50% and those with total occlusion (P < .01 for all). There were no significant differences between stents with no ISR and those with an ISR of less than 50% (P = .821) and between stents with an ISR of at least 50% and those with an ISR of 100% (P = .836). The CCO difference across coronary stents is related to ISR severity in

  9. The psychological impact of test results following diagnostic coronary CT angiography.

    PubMed

    Devcich, Daniel A; Ellis, Christopher J; Broadbent, Elizabeth; Gamble, Greg; Petrie, Keith J

    2012-11-01

    Coronary computed tomography (CT) angiography is an advanced cardiac imaging test commonly used for diagnosing early signs of ischemic heart disease. Despite its importance in cardiology, little is known about its psychological effect on patients. The present study sought to examine these effects in relation to illness perceptions, cardiac health behavior intentions, and subsequent health behaviors. Forty-five nonacute cardiac patients who were referred for diagnostic coronary CT angiography completed questionnaires prior to testing and following the receipt of test results, at which point illness perceptions and intentions to take cardiac medication, as well as diet and exercise intentions were measured. Exercise and dietary behaviors were measured at follow-up 6 weeks later. Changes on these variables were then compared between patients diagnosed with normal arteries and patients diagnosed with diseased arteries. Compared to positive-testing patients, patients with normal test results reported significant changes toward more positive illness perceptions following testing, with improvements in emotional effect of illness, illness concern, consequences, and personal control of illness. The illness perception of treatment control was seen as more important among positive-testing patients, whereas both groups reported increases in illness coherence. Health behavior intentions (cardiac medication intentions and exercise intentions) increased for positive-testing patients only, as did physical activity at follow-up. Diagnosis-dependent psychological effects can be detected following coronary CT angiography. These effects have important implications for patient health and health care in diagnostic contexts, and the results from this study can be used to guide further research in this area.

  10. Assessment of vasoreactivity using videodensitometry coronary angiography.

    PubMed

    Molloi, Sabee; Berenji, Gholam R; Dang, Trien T; Kassab, Ghassan

    2003-08-01

    Previous studies demonstrated that the dysfunction of vasomotor tone (VT) is closely linked to the development of atherosclerosis and it is considered important in the very early stages of atherogenesis. Currently, the evaluation of VT relies on lumen changes in response to vasoactive stimuli using quantitative coronary angiography (QCA) based on geometric edge detection (ED). However, using ED for measuring lumen diameters is inherently associated with large uncertainties. Videodensitometry (VD) methods have important advantages over ED for QCA. The objective of this study was to investigate the reliability of VD and ED techniques in determining the effect of nitroglycerin (NTG) on cross-sectional area (CSA) and volume changes in a swine animal model for evaluating coronary vasoreactivity. Coronary angiography was performed on four anesthetized swine. CSA and volume were measured in the left anterior descending (LAD) coronary artery using VD before and after intracoronary injection of 0.3 mg of NTG. CSA was also calculated using standard QCA based on ED. The average CSA changes in the proximal, middle and distal branches measured using VD were 23.83% (+/-10.76%), 30.78% (+/-18.39%), and 27.34% (+/-36.53%), respectively. Similarly, the average CSA changes in the proximal, middle, and distal branches measured using ED were 15.02% (+/-36.38%), 22.02% (+/-26.12), and 38.00% (+/-48.31%), respectively. The average lumen volume change measured using VD was 29.79% (+/-14.79%). In order to evaluate the relative reliability of the techniques. the significance of deviation (SOD) was calculated, which is the ratio of the change after NTG and the measurement error. The average SOD for CSA for all the branches based on VD and ED were 1.86 and 0.69, respectively. The SOD for volume measurement was 2.78. Lumen changes measured by VD showed substantial improvement in reliability when compared to the ED. Moreover, VD can be used to measure substantially smaller changes in lumen

  11. Sex Differences in Cardiac Medication Use Post-Catheterization in Patients Undergoing Coronary Angiography for Stable Angina with Nonobstructive Coronary Artery Disease.

    PubMed

    Galway, Shannon; Adatia, Falisha; Grubisic, Maja; Lee, May; Daniele, Patrick; Humphries, Karin H; Sedlak, Tara L

    2017-09-01

    Treatment of patients with stable angina and nonobstructive coronary artery disease (CAD) has not been well characterized. We comparatively evaluated medication use in males and females with stable angina with no CAD, nonobstructive CAD, and obstructive CAD. We studied all patients ≥20 years old with stable angina undergoing coronary angiography in British Columbia (BC), Canada, from January 2008 to March 2010 (n = 7,535). No CAD, nonobstructive CAD, and obstructive CAD were defined as 0%, 1%-49%, and ≥50% luminal narrowing in any epicardial coronary artery, respectively. Medication use, 3 months before and 3 months following angiography, was obtained through BC PharmaNet for angiotensin-converting enzyme inhibitors (ACE-I), angiotensin receptor blockers (ARBs), calcium channel blockers (CCBs), beta-blockers, statins, antiplatelet agents, and prescriptions for all three ACE-I/ARBs, beta-blockers, and statins (combination therapy). Following angiography, patients with no and nonobstructive CAD had significantly lower rates of prescription use of all medications, including combination therapy, than patients with obstructive CAD (p < 0.001). Use of ACE-I/ARBs, beta-blockers, statins, and combination therapy did not differ by sex, but females had higher use of CCB in all CAD groups, and clopidogrel in nonobstructive and obstructive CAD groups, compared to males. In patients with stable angina, medication use following angiography is low in nonobstructive CAD with only 58.9% prescribed a statin and 19.4% on combination therapy at 3 months. There are no important sex differences in medication use in any CAD category post-angiography. Future studies should explore methods of improving quality of care in patients with nonobstructive CAD.

  12. Impact of coronary calcium score on the prevalence of coronary artery stenosis on dual source CT coronary angiography in caucasian patients with an intermediate risk.

    PubMed

    Meyer, Mathias; Henzler, Thomas; Fink, Christian; Vliegenthart, Rozemarijn; Barraza, J Michael; Nance, John W; Apfaltrer, Paul; Schoenberg, Stefan O; Wasser, Klaus

    2012-11-01

    To investigate the prevalence of significant coronary artery stenosis on coronary computed tomography angiography (cCTA) in symptomatic Caucasian patients with an intermediate risk score at different levels of coronary artery calcification (CAC). In total, 383 consecutive symptomatic Caucasian patients (147 females, 60 ± 13 years) with an intermediate risk score underwent nonenhanced CT for CAC scoring immediately before contrast-enhanced cCTA on a dual-source CT scanner. Additionally clinically indicated invasive coronary angiography (ICA) was performed in 90 patients. The prevalence of significant coronary artery stenosis (>50%) on cCTA and ICA was correlated at different CAC score levels. Of 121 patients with a zero CAC score, none had significant coronary artery stenosis on cCTA or ICA. Coronary CTA diagnosed in 54 of 70 patients with high CAC score (>400), a significant stenosis. Subsequent ICA confirmed significant stenosis in 30 of 32 patients. Sensitivity and a negative predictive value of CAC score ruling out significant stenosis on cCTA were 100% and 100%, respectively, using cutoff value of zero and specificity and positive predictive value to predict significant stenosis on cCTA were 79% and 51%, respectively, using a cutoff value of >400. Significant coronary artery stenosis is extremely unlikely, with an estimated risk of 4 in 1000 patients in symptomatic Caucasian patients with an intermediate risk score and negative CAC score. To reduce radiation exposure, radiation-free tests should be considered for differential diagnosis of chest pain in these patients. Copyright © 2012 AUR. Published by Elsevier Inc. All rights reserved.

  13. An initiative to minimize amount of contrast media utilizing a novel rotational coronary sinus occlusive venography technique with ordinary cath-lab X-ray machine during CRT implantation.

    PubMed

    Al Fagih, Ahmed; Al Ghamdi, Saleh; El Tayeb, Areeg; Dagriri, Khaled

    2010-09-01

    Rotational angiography is one of the latest angiographic modalities to map the coronary venous tree anatomy. It provides a significant reduction in both contrast agent usage and radiation dose (up to 30%), without compromising the clinical utility of images. Hence, the present study was conducted to describe a new technique to minimize the amount of contrast media used during cardiac resynchronization therapy (CRT) implantation. The SL3 sheath was inserted into the right atrium via the femoral vein followed by withdrawal of the dilator. The tip of the sheath was manipulated to the vicinity of the coronary sinus (CS) ostium (OS). The CS was entered using a deflated balloon catheter. The sheath was then advanced gently beyond the CS OS. Occlusive venography was performed using 5-8 ml of contrast media in a rotational view starting from 45 degrees LAO to 0 degrees AP while holding the inflated balloon for a few seconds. Data from 30 consecutive patients who underwent CRT implantation were analyzed. The feasibility of rotational angiography, while occluding the CS with a specialized long, preshaped sheath and using an ordinary cath-lab imaging machine, was supported by the correctly delineated CS anatomy of all patients without any complications and death related to the placement of the CS catheters or sheaths. The mean contrast dose used for the entire procedure in all patients undergoing CRT was 14.76 +/- 6.8 ml. Use of rotational CS occlusive venography utilizing an ordinary cath-lab X-ray machine minimizes the use of contrast media during CRT implantation without compromising the visualized anatomy.

  14. Contrast Media Administration in Coronary Computed Tomography Angiography - A Systematic Review.

    PubMed

    Mihl, Casper; Maas, Monique; Turek, Jakub; Seehofnerova, Anna; Leijenaar, Ralph T H; Kok, Madeleine; Lobbes, Marc B I; Wildberger, Joachim E; Das, Marco

    2017-04-01

    Background  Various different injection parameters influence enhancement of the coronary arteries. There is no consensus in the literature regarding the optimal contrast media (CM) injection protocol. The aim of this study is to provide an update on the effect of different CM injection parameters on the coronary attenuation in coronary computed tomographic angiography (CCTA). Method  Studies published between January 2001 and May 2014 identified by Pubmed, Embase and MEDLINE were evaluated. Using predefined inclusion criteria and a data extraction form, the content of each eligible study was assessed. Initially, 2551 potential studies were identified. After applying our criteria, 36 studies were found to be eligible. Studies were systematically assessed for quality based on the validated Quality Assessment of Diagnostic Accuracy Studies (QUADAS)-II checklist. Results  Extracted data proved to be heterogeneous and often incomplete. The injection protocol and outcome of the included publications were very diverse and results are difficult to compare. Based on the extracted data, it remains unclear which of the injection parameters is the most important determinant for adequate attenuation. It is likely that one parameter which combines multiple parameters (e. g. IDR) will be the most suitable determinant of coronary attenuation in CCTA protocols. Conclusion  Research should be directed towards determining the influence of different injection parameters and defining individualized optimal IDRs tailored to patient-related factors (ideally in large randomized trials). Key points   · This systematic review provides insight into decisive factors on coronary attenuation.. · Different and contradicting outcomes are reported on coronary attenuation in CCTA.. · One parameter combining multiple parameters (IDR) is likely decisive in coronary attenuation.. · Research should aim at defining individualized optimal IDRs tailored to individual factors.. · Future

  15. [Initial experience of percutaneous coronary intervention guided by computed tomography coronary angiography derived roadmap and magnetic navigation system].

    PubMed

    Zhang, Qiu; Kong, De-yu; Li, Chun-jian; Chen, Bo; Jia, En-zhi; Chen, Lei-Lei; Jia, Qing-zhe; Dai, Zhen-hua; Zhu, Tian-tian; Chen, Jun; Liu, Jie; Zhu, Tie-bing; Yang, Zhi-jian; Cao, Ke-jiang

    2013-02-01

    To evaluate the feasibility, efficacy and safety of the percutaneous coronary intervention (PCI)guided by computed tomography (CT) coronary angiography derived roadmap and magnetic navigation system (MNS). During June 2011 and May 2012, thirty consecutive patients receiving elective PCI were enrolled, coronary artery disease was primarily diagnosed by dual-source CT coronary angiography (DSCT-CA) at outpatient clinic and successively proved by coronary artery angiography in the hospital. Target vessels from pre-procedure DSCT-CA were transferred to the magnetic navigation system, and consequently edited, reconstructed, and projected onto the live fluoroscopic screen as roadmap. Parameters including characters of the target lesions, time, contrast volume, radiation dosage for guidewire crossing, and complications of the procedure were recorded. Thirty patients with 36 lesions were recruited and intervened by PCI. Among the target lesions, sixteen were classified as type A, 11 as type B1, 8 as type B2, 1 as type C. The average length of the target lesions was (22.0 ± 9.8) mm, and the average stenosis of the target lesions was (81.3 ± 10.3)%. Under the guidance of CT roadmap and MNS, 36 target lesions were crossed by the magnetic guidewires, with a lesion crossing ratio of 100%. The time of placement of the magnetic guidewires was 92.5 (56.6 - 131.3) seconds. The contrast volume and the radiation dosage for guidewire placement were 0.0 (0.0 - 3.0) ml and 235.0 (123.5 - 395.1) µGym(2)/36.5 (21.3 - 67.8) mGy, respectively. Guidewires were successfully placed in 21 (58.3%) lesions without contrast agent. All enrolled vessels were successfully treated, and there were no MNS associated complications. It is feasible, effective and safe to initiate PCI under the guidance of CT derived roadmap and MNS. This method might be helpful for the guidewire placement in the treatment of total occlusions.

  16. Optimal reconstruction interval in dual source CT coronary angiography: a single-center experience in 285 patients

    PubMed Central

    Akgöz, Ayça; Akata, Deniz; Hazırolan, Tuncay; Karçaaltıncaba, Muşturay

    2014-01-01

    PURPOSE We aimed to evaluate the visibility of coronary arteries and bypass-grafts in patients who underwent dual source computed tomography (DSCT) angiography without heart rate (HR) control and to determine optimal intervals for image reconstruction. MATERIALS AND METHODS A total of 285 consecutive cases who underwent coronary (n=255) and bypass-graft (n=30) DSCT angiography at our institution were identified retrospectively. Patients with atrial fibrillation were excluded. Ten datasets in 10% increments were reconstructed in all patients. On each dataset, the visibility of coronary arteries was evaluated using the 15-segment American Heart Association classification by two radiologists in consensus. RESULTS Mean HR was 76±16.3 bpm, (range, 46–127 bpm). All coronary segments could be visualized in 277 patients (97.19%). On a segment-basis, 4265 of 4275 (99.77%) coronary artery segments were visible. All segments of 56 bypass-grafts in 30 patients were visible (100%). Total mean segment visibility scores of all coronary arteries were highest at 70%, 40%, and 30% intervals for all HRs. The optimal reconstruction intervals to visualize the segments of all three coronary arteries in descending order were 70%, 60%, 80%, and 30% intervals in patients with a mean HR <70 bpm; 40%, 70%, and 30% intervals in patients with a mean HR 70–100 bpm; and 40%, 50%, and 30% in patients with a mean HR >100 bpm. CONCLUSION Without beta-blocker administration, DSCT coronary angiography offers excellent visibility of vascular segments using both end-systolic and mid-late diastolic reconstructions at HRs up to 100 bpm, and only end-systolic reconstructions at HRs over 100 bpm. PMID:24834490

  17. Coronary atherosclerosis evaluation among Iranian patients with zero coronary calcium score in computed tomography coronary angiography.

    PubMed

    Moradi, Maryam; Varasteh, Elham

    2016-01-01

    Coronary artery calcification (CAC) is a specific indicator of and a sensitive marker for the atherosclerotic disease process. However, calcium scoring may miss noncalcified plaques with clinical importance. The present study aimed to identify the presence and extent of coronary plaques in computed tomography coronary angiography (CTCA) in patients with a zero CAC score and the secondary endpoint was to evaluate the association between coronary risk factors and the presence of noncalcified plaques. In a retrospective descriptive-analytic study, a total of 2000 consecutive patients who undergone CTCA between September 2012 and September 2014 at Alzahra Hospital in Isfahan, Iran were analyzed. Three hundred and eighty-five patients with a zero calcium score were included in the study. The demographic information and coronary artery disease (CAD), risk factors including diabetes mellitus (DM), hypertension, hyperlipidemia, smoking, and family history of CAD, were obtained from the questionnaire. Furthermore, the presence of plaques and extent of stenosis were evaluated in patients with zero CAC score. Of the 385 patients with a zero calcium score, 16 (4.2%) had atherosclerotic plaques. Among them, 6 (1.6%) had significant (>50%) coronary stenosis, and 10 (2.6%) had no significant (<50%) coronary stenosis. Hyperlipidemia, DM, and smoking were significantly associated with obstructive CAD. Furthermore, in patients with zero calcium score, DM, hyperlipidemia, and smoking had odds ratios of 5.9, 14, and 32.5 for the development of coronary artery plaques, respectively. Although, CAC scoring is a noninvasive and valuable method to evaluate CAD; but zero CAC score does not absolutely exclude the CAD, especially in the presence of risk factors such as diabetes, hyperlipidemia, and smoking.

  18. Inpatient Coronary Angiography and Revascularisation following Non-ST-Elevation Acute Coronary Syndrome in Patients with Renal Impairment: A Cohort Study Using the Myocardial Ischaemia National Audit Project

    PubMed Central

    Shaw, Catriona; Nitsch, Dorothea; Steenkamp, Retha; Junghans, Cornelia; Shah, Sapna; O’Donoghue, Donal; Fogarty, Damian; Weston, Clive; Sharpe, Claire C.

    2014-01-01

    Background International guidelines support an early invasive management strategy (including early coronary angiography and revascularisation) for non-ST-elevation acute coronary syndrome (NSTE-ACS) in patients with renal impairment. However, evidence from outside the UK suggests that this approach is underutilised. We aimed to describe practice within the NHS, and to determine whether the severity of renal dysfunction influenced the provision of angiography and modified the association between early revascularisation and survival. Methods We performed a cohort study, using multivariable logistic regression and propensity score analyses, of data from the Myocardial Ischaemia National Audit Project for patients presenting with NSTE-ACS to English or Welsh hospitals between 2008 and 2010. Findings Of 35 881 patients diagnosed with NSTE-ACS, eGFR of <60 ml/minute/1.73 m2 was present in 15 680 (43.7%). There was a stepwise decline in the odds of undergoing inpatient angiography with worsening renal dysfunction. Compared with an eGFR>90 ml/minute/1.73 m2, patients with an eGFR between 45–59 ml/minute/1.73 m2 were 33% less likely to undergo angiography (adjusted OR 0.67, 95% CI 0.55–0.81); those with an eGFR<30/minute/1.73 m2 had a 64% reduction in odds of undergoing angiography (adjusted OR 0.36, 95%CI 0.29–0.43). Of 16 646 patients who had inpatient coronary angiography, 58.5% underwent inpatient revascularisation. After adjusting for co-variables, inpatient revascularisation was associated with approximately a 30% reduction in death within 1 year compared with those managed medically after coronary angiography (adjusted OR 0.66, 95%CI 0.57–0.77), with no evidence of modification by renal function (p interaction = 0.744). Interpretation Early revascularisation may offer a similar survival benefit in patients with and without renal dysfunction, yet renal impairment is an important determinant of the provision of coronary angiography following NSTE-ACS. A

  19. Cost-effectiveness of 64-slice CT angiography compared to conventional coronary angiography based on a coverage with evidence development study in Ontario.

    PubMed

    Goeree, Ron; Blackhouse, Gord; Bowen, James M; O'Reilly, Daria; Sutherland, Simone; Hopkins, Robert; Chow, Benjamin; Freeman, Michael; Provost, Yves; Dennie, Carole; Cohen, Eric; Marcuzzi, Dan; Iwanochko, Robert; Moody, Alan; Paul, Narinder; Parker, John D

    2013-10-01

    Conventional coronary angiography (CCA) is the standard diagnostic for coronary artery disease (CAD), but multi-detector computed tomography coronary angiography (CTCA) is a non-invasive alternative. A multi-center coverage with evidence development study was undertaken and combined with an economic model to estimate the cost-effectiveness of CTCA followed by CCA vs CCA alone. Alternative assumptions were tested in patient scenario and sensitivity analyses. CCA was found to dominate CTCA, however, CTCA was relatively more cost-effective in females, in advancing age, in patients with lower pre-test probabilities of CAD, the higher the sensitivity of CTCA and the lower the probability of undergoing a confirmatory CCA following a positive CTCA. RESULTS were very sensitive to alternative patient populations and modeling assumptions. Careful consideration of patient characteristics, procedures to improve the diagnostic yield of CTCA and selective use of CCA following CTCA will impact whether CTCA is cost-effective or dominates CCA.

  20. Non-invasive coronary angiography: the clinical value of multi-slice computed tomography in the assessment of patients with prior coronary bypass surgery. Evaluating grafts and native vessels.

    PubMed

    von Kiedrowski, Helge; Wiemer, Marcus; Franzke, Krista; Preuss, Rainer; Vaske, Bernhard; Butz, Thomas; Oldenburg, Olaf; Bitter, Thomas; Mahmood, Khalid; Burchert, Wolfram; Horstkotte, Dieter; Langer, Christoph

    2009-02-01

    Contrast enhanced multi-slice computed tomography (MSCT) is the leading modality in non-invasive coronary angiography (CTA) today. We investigated MSCT based assessment of coronary artery bypass grafts (CABG) by analyzing assets and drawbacks of CTA in order to define demands on latest technology. In a clinical setting 39 CABG patients (69.2 +/- 1.4 years; male n = 36) underwent CTA (collimation 16 x 0.75 mm, contrast medium 100 ml; 320 mAs, 120 KV). Ninety-seven CABG (61 venous, 36 arterial grafts) were evaluated. A subgroup of 18 patients underwent additional invasive coronary angiography (CA). CTA for CABG assessment resulted in an overall sensitivity (sens.) of 100%, specificity (spec.) of 92.4% and positive and negative predictive values (PPV, NPV) of 60% and 100%, respectively. CABG anastomoses showed slightly inferior diagnostic accuracy than other CABG segments. Limitations in imaging quality caused 21% unevaluable segments of the CABG anastomoses. Evaluation of native vessel segments proximal and distal to the anastomoses resulted in a sens, spec, PPV and NPV of 57.5, 94.6, 92 and 67.3%, respectively. With 28.5% unevaluable segments, the native vessel segments showed serious limitations in imaging quality. Radiation exposure was 9.88 +/- 3.20 mSv (9.69 +/- 3.25 mSv male; 12.08 +/- 1.35 mSv female). 16-slice MSCT based CABG assessment offers sufficient diagnostic accuracy. However, focussing on the bypass anastomoses and the native revascularized coronary arteries, clinical value is limited.

  1. Coronary Artery Anomalies and Variants: Technical Feasibility of Assessment with Coronary MR Angiography at 3 T1

    PubMed Central

    Gharib, Ahmed M.; Ho, Vincent B.; Rosing, Douglas R.; Herzka, Daniel A.; Stuber, Matthias; Arai, Andrew E.; Pettigrew, Roderic I.

    2008-01-01

    The purpose of this study was to prospectively use a whole-heart three-dimensional (3D) coronary magnetic resonance (MR) angiography technique specifically adapted for use at 3 T and a parallel imaging technique (sensitivity encoding) to evaluate coronary arterial anomalies and variants (CAAV). This HIPAA-compliant study was approved by the local institutional review board, and informed consent was obtained from all participants. Twenty-two participants (11 men, 11 women; age range, 18–62 years) were included. Ten participants were healthy volunteers, whereas 12 participants were patients suspected of having CAAV. Coronary MR angiography was performed with a 3-T MR imager. A 3D free-breathing navigator-gated and vector electrocardiographically–gated segmented k-space gradient-echo sequence with adiabatic T2 preparation pulse and parallel imaging (sensitivity encoding) was used. Whole-heart acquisitions (repetition time msec/echo time msec, 4/1.35; 20° flip angle; 1 × 1 × 2-mm acquired voxel size) lasted 10–12 minutes. Mean examination time was 41 minutes ± 14 (standard deviation). Findings included aneurysms, ectasia, arteriovenous fistulas, and anomalous origins. The 3D whole-heart acquisitions developed for use with 3 T are feasible for use in the assessment of CAAV. © RSNA, 2008 PMID:18372470

  2. Clinical outcomes of patients with acute coronary syndrome and moderate or severe chronic anaemia undergoing coronary angiography or intervention.

    PubMed

    Ohana-Sarna-Cahan, Lea; Atar, Shaul

    2017-05-01

    There are limited data on the impact of chronic moderate or severe anaemia on the clinical outcomes of patients with acute coronary syndrome undergoing coronary angiography or percutaneous coronary intervention. We retrospectively compared two groups of consecutive patients with acute coronary syndrome according to their haemoglobin level on admission. The research group ( n=89) had a haemoglobin level of 10.9 g/dl or less and a control group ( n=79) of age-matched patients had a haemoglobin level greater than 10.9 g/dl. We studied drug therapy before, during and after intervention, and performed 1-year follow-up of bleeding complications according to the Bleeding Academic Research Consortium criteria, all-cause mortality and re-infarction, as well as haemoglobin level on discharge, 6 and 12 months after admission. Compared to controls, a haemoglobin level less than 10.9 g\\dl on admission is associated with a higher rate of major bleeding: 26 patients (32%) versus none in the control group ( P<0.001); and the use of packed red blood cell (RBC) transfusion: nine patients (11.7%) versus none in the control group ( P=0.003) within the first 6 months post-catheterisation. However, the re-infarction rate and mortality were similar in the study and control groups: 9.2% versus 9.7% ( P=0.915) and 12.6% versus 8.9% ( P=0.434), accordingly. Chronic moderate or severe anaemia in patients with acute coronary syndrome undergoing coronary angiography or percutaneous coronary intervention is associated with a substantially increased risk of bleeding in the first 6 months. However, rates of mortality and re-infarction were similar.

  3. Comparing treatment outcomes of fractional flow reserve-guided and angiography-guided percutaneous coronary intervention in patients with multi-vessel coronary artery diseases: a systematic review and meta-analysis.

    PubMed

    Xiu, Jiancheng; Chen, Gangbin; Zheng, Hua; Wang, Yuegang; Chen, Haibin; Liu, Xuewei; Wu, Juefei; Bin, Jianping

    2016-02-01

    Fractional flow reserve (FFR)-guided percutaneous coronary intervention (PCI) is used to assess the need for angioplasty in vessels with intermediate blockages. The treatment outcomes of FFR-guided vs. conventional angiography-guided PCI were evaluated in patients with multi-vessel coronary artery disease (CAD). Prospective and retrospective studies comparing FFR-guided vs. angiography-guided PCI in patients with multi-vessel CAD were identified from medical databases by two independent reviewers using the terms "percutaneous coronary intervention, fractional flow reserve, angiography, coronary heart disease, major adverse cardiac events (MACE) and myocardial infarction". The primary outcome was the number of stents placed, and the secondary outcomes were procedure time, mortality, myocardial infarction (MI) and MACE rates. Seven studies (three retrospective and four prospective), which included 49,517 patients, were included in this review. A total of 4,755 patients underwent FFR, while 44,697 received angiography-guided PCI. The mean patient age ranged from 58 to 71.7 years. The average number of stents used in FFR patients ranged from 0.3-1.9, and in angiography-guided PCI patients ranged from 0.7-2.7. Analysis indicated there was a greater number of stents placed in the angiography-guided group compared with the FFR group (pooled difference in means: -0.64, 95% confidence interval [CI]: -0.81 to -0.47, P < 0.001). There were no differences in the secondary outcomes between the two groups. Both procedures produce similar clinical outcomes, but the fewer number of stents used with FFR may have clinical as was as cost implications.

  4. Diagnostic accuracy of high-definition CT coronary angiography in high-risk patients.

    PubMed

    Iyengar, S S; Morgan-Hughes, G; Ukoumunne, O; Clayton, B; Davies, E J; Nikolaou, V; Hyde, C J; Shore, A C; Roobottom, C A

    2016-02-01

    To assess the diagnostic accuracy of computed tomography coronary angiography (CTCA) using a combination of high-definition CT (HD-CTCA) and high level of reader experience, with invasive coronary angiography (ICA) as the reference standard, in high-risk patients for the investigation of coronary artery disease (CAD). Three hundred high-risk patients underwent HD-CTCA and ICA. Independent experts evaluated the images for the presence of significant CAD, defined primarily as the presence of moderate (≥ 50%) stenosis and secondarily as the presence of severe (≥ 70%) stenosis in at least one coronary segment, in a blinded fashion. HD-CTCA was compared to ICA as the reference standard. No patients were excluded. Two hundred and six patients (69%) had moderate and 178 (59%) had severe stenosis in at least one vessel at ICA. The sensitivity, specificity, positive predictive value, and negative predictive value were 97.1%, 97.9%, 99% and 93.9% for moderate stenosis, and 98.9%, 93.4%, 95.7% and 98.3%, for severe stenosis, on a per-patient basis. The combination of HD-CTCA and experienced readers applied to a high-risk population, results in high diagnostic accuracy comparable to ICA. Modern generation CT systems in experienced hands might be considered for an expanded role. Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  5. Early detection of lung cancer using ultra-low-dose computed tomography in coronary CT angiography scans among patients with suspected coronary heart disease.

    PubMed

    Zanon, Matheus; Pacini, Gabriel Sartori; de Souza, Vinicius Valério Silveiro; Marchiori, Edson; Meirelles, Gustavo Souza Portes; Szarf, Gilberto; Torres, Felipe Soares; Hochhegger, Bruno

    2017-12-01

    To assess whether an additional chest ultra-low-dose CT scan to the coronary CT angiography protocol can be used for lung cancer screening among patients with suspected coronary artery disease. 175 patients underwent coronary CT angiography for assessment of coronary artery disease, additionally undergoing ultra-low-dose CT screening to early diagnosis of lung cancer in the same scanner (80kVp and 15mAs). Patients presenting pulmonary nodules were followed-up for two years, repeating low-dose CTs in intervals of 3, 6, or 12 months based on nodule size and growth rate in accordance with National Comprehensive Cancer Network guidelines. Ultra-low-dose CT identified 71 patients with solitary pulmonary nodules (41%), with a mean diameter of 5.50±4.00mm. Twenty-eight were >6mm, and in 79% (n=22) of these cases they were false positive findings, further confirmed by follow-up (n=20), resection (n=1), or biopsy (n=1). Lung cancer was detected in six patients due to CT screening (diagnostic yield: 3%). Among these, four cases could not be detected in the cardiac field of view. Most patients were in early stages of the disease. Two patients diagnosed at advanced stages died due to cancer complications. The addition of the ultra-low-dose CT scan represented a radiation dose increment of 1.22±0.53% (effective dose, 0.11±0.03mSv). Lung cancer might be detected using additional ultra-low-dose protocols in coronary CT angiography scans among patients with suspected coronary artery disease. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Two-dimensional aortographic coronary angiography with synchrotron radiation at aortic regurgitation state

    NASA Astrophysics Data System (ADS)

    Takeda, Tohoru; Umetani, Keiji; Doi, Toshiki; Itai, Yuji; Yu, Quanwen; Akatsuka, Takao

    1999-10-01

    At aortic regurgitation state, 2D synchrotron radiation (SR) coronary arteriography (CAG) with aortographic contrast injection was examined theoretically and animal experiments were performed to confirm its diagnostic ability. This system consisted of a silicon monocrystal, fluorescent plate, avalanche-type pickup tube camera, and image acquisition system. The experiment was performed at synchrotron sources in the Photon Factory of Tsukuba. The x- ray energy was adjusted to just above the iodine K-edge. Theoretical calculation described that the coronary arteries overlapping on left ventricle could not be demonstrated well with a high signal-to-noise ratio by using the aortographic CAG with SR. The canine coronary arteries without overlap over the left ventricle were demonstrated clearly, however, the image quality appear to be reduced. The coronary artery overlapping over left ventricle could not be demonstrated well, however the transient reduction of left ventricular wall motion was revealed by transient stenotic procedure of left anterior descending coronary artery.

  7. Unanswered questions for management of acute coronary syndrome: risk stratification of patients with minimal disease or normal findings on coronary angiography.

    PubMed

    Bugiardini, Raffaele; Manfrini, Olivia; De Ferrari, Gaetano M

    2006-07-10

    The prognostic implication of chest pain associated with normal or near-normal findings on angiography is still unknown. We explored outcomes and methods of risk stratification in patients with nonobstructive coronary artery disease in the setting of non-ST-segment elevation acute coronary syndromes. Data were pooled from 3 Thrombolysis in Myocardial Infarction (TIMI) trials (TIMI 11B, TIMI 16, and TIMI 22). Angiographic data were available on 7656 patients with non-ST-segment elevation acute coronary syndromes. The primary end point of this analysis was the composite of the rates of death, myocardial infarction, unstable angina requiring rehospitalization, revascularization, and stroke at 1-year follow-up. Outcomes were evaluated by mean of the TIMI risk score for developing at least 1 component of the primary end point. Angiographic findings showed that 710 (9.1%) of 7656 patients had nonobstructive coronary artery disease; 48.7% of these had normal coronary arteries (0% stenosis), and 51.3% had mild coronary artery disease (>0% to <50% stenosis). A primary end-point event occurred in 101 patients (12.1%). It is noteworthy that a 2% event rate of deaths and myocardial infarctions had occurred in these patients at the 1-year follow-up. Event rates of death and myocardial infarction increased significantly as the TIMI risk score increased from 0.6% for a score of 1 to 4.0% for a score greater than 4. Patients with non-ST-segment elevation acute coronary syndromes with nonobstructive coronary artery disease detected by angiography have a substantial risk of subsequent coronary events within 1 year. The risk is not univariately high, and the TIMI risk score helps to reveal patients at high risk.

  8. Does clinical pretest probability influence image quality and diagnostic accuracy in dual-source coronary CT angiography?

    PubMed

    Thomas, Christoph; Brodoefel, Harald; Tsiflikas, Ilias; Bruckner, Friederike; Reimann, Anja; Ketelsen, Dominik; Drosch, Tanja; Claussen, Claus D; Kopp, Andreas; Heuschmid, Martin; Burgstahler, Christof

    2010-02-01

    To prospectively evaluate the influence of the clinical pretest probability assessed by the Morise score onto image quality and diagnostic accuracy in coronary dual-source computed tomography angiography (DSCTA). In 61 patients, DSCTA and invasive coronary angiography were performed. Subjective image quality and accuracy for stenosis detection (>50%) of DSCTA with invasive coronary angiography as gold standard were evaluated. The influence of pretest probability onto image quality and accuracy was assessed by logistic regression and chi-square testing. Correlations of image quality and accuracy with the Morise score were determined using linear regression. Thirty-eight patients were categorized into the high, 21 into the intermediate, and 2 into the low probability group. Accuracies for the detection of significant stenoses were 0.94, 0.97, and 1.00, respectively. Logistic regressions and chi-square tests showed statistically significant correlations between Morise score and image quality (P < .0001 and P < .001) and accuracy (P = .0049 and P = .027). Linear regression revealed a cutoff Morise score for a good image quality of 16 and a cutoff for a barely diagnostic image quality beyond the upper Morise scale. Pretest probability is a weak predictor of image quality and diagnostic accuracy in coronary DSCTA. A sufficient image quality for diagnostic images can be reached with all pretest probabilities. Therefore, coronary DSCTA might be suitable also for patients with a high pretest probability. Copyright 2010 AUR. Published by Elsevier Inc. All rights reserved.

  9. Visual and Quantitative Assessment of Coronary Stenoses at Angiography Versus Fractional Flow Reserve: The Impact of Risk Factors.

    PubMed

    Adjedj, Julien; Xaplanteris, Panagiotis; Toth, Gabor; Ferrara, Angela; Pellicano, Mariano; Ciccarelli, Giovanni; Floré, Vincent; Barbato, Emanuele; De Bruyne, Bernard

    2017-07-01

    The correlation between angiographic assessment of coronary stenoses and fractional flow reserve (FFR) is weak. Whether and how risk factors impact the diagnostic accuracy of angiography is unknown. We sought to evaluate the diagnostic accuracy of angiography by visual estimate and by quantitative coronary angiography when compared with FFR and evaluate the influence of risk factors (RF) on this accuracy. In 1382 coronary stenoses (1104 patients), percent diameter stenosis by visual estimation (DS VE ) and by quantitative coronary angiography (DS QCA ) was compared with FFR. Patients were divided into 4 subgroups, according to the presence of RFs, and the relationship between DS VE , DS QCA , and FFR was analyzed. Overall, DS VE was significantly higher than DS QCA ( P <0.0001); nonetheless, when examined by strata of DS, DS VE was significantly smaller than DS QCA in mild stenoses, although the reverse held true for severe stenoses. Compared with FFR, a large scatter was observed for both DS VE and DS QCA . When using a dichotomous FFR value of 0.80, C statistic was significantly higher for DS VE than for DS QCA (0.712 versus 0.640, respectively; P <0.001). C statistics for DS VE decreased progressively as RFs accumulated (0.776 for ≤1 RF, 0.750 for 2 RFs, 0.713 for 3 RFs and 0.627 for ≥4 RFs; P =0.0053). In addition, in diabetics, the relationship between FFR and angiographic indices was particularly weak (C statistics: 0.524 for DS VE and 0.511 for DS QCA ). Overall, DS VE has a better diagnostic accuracy than DS QCA to predict the functional significance of coronary stenosis. The predictive accuracy of angiography is moderate in patients with ≤1 RFs, but weakens as RFs accumulate, especially in diabetics. © 2017 American Heart Association, Inc.

  10. Standardized evaluation framework for evaluating coronary artery stenosis detection, stenosis quantification and lumen segmentation algorithms in computed tomography angiography.

    PubMed

    Kirişli, H A; Schaap, M; Metz, C T; Dharampal, A S; Meijboom, W B; Papadopoulou, S L; Dedic, A; Nieman, K; de Graaf, M A; Meijs, M F L; Cramer, M J; Broersen, A; Cetin, S; Eslami, A; Flórez-Valencia, L; Lor, K L; Matuszewski, B; Melki, I; Mohr, B; Oksüz, I; Shahzad, R; Wang, C; Kitslaar, P H; Unal, G; Katouzian, A; Örkisz, M; Chen, C M; Precioso, F; Najman, L; Masood, S; Ünay, D; van Vliet, L; Moreno, R; Goldenberg, R; Vuçini, E; Krestin, G P; Niessen, W J; van Walsum, T

    2013-12-01

    Though conventional coronary angiography (CCA) has been the standard of reference for diagnosing coronary artery disease in the past decades, computed tomography angiography (CTA) has rapidly emerged, and is nowadays widely used in clinical practice. Here, we introduce a standardized evaluation framework to reliably evaluate and compare the performance of the algorithms devised to detect and quantify the coronary artery stenoses, and to segment the coronary artery lumen in CTA data. The objective of this evaluation framework is to demonstrate the feasibility of dedicated algorithms to: (1) (semi-)automatically detect and quantify stenosis on CTA, in comparison with quantitative coronary angiography (QCA) and CTA consensus reading, and (2) (semi-)automatically segment the coronary lumen on CTA, in comparison with expert's manual annotation. A database consisting of 48 multicenter multivendor cardiac CTA datasets with corresponding reference standards are described and made available. The algorithms from 11 research groups were quantitatively evaluated and compared. The results show that (1) some of the current stenosis detection/quantification algorithms may be used for triage or as a second-reader in clinical practice, and that (2) automatic lumen segmentation is possible with a precision similar to that obtained by experts. The framework is open for new submissions through the website, at http://coronary.bigr.nl/stenoses/. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. Software-based on-site estimation of fractional flow reserve using standard coronary CT angiography data.

    PubMed

    De Geer, Jakob; Sandstedt, Mårten; Björkholm, Anders; Alfredsson, Joakim; Janzon, Magnus; Engvall, Jan; Persson, Anders

    2016-10-01

    The significance of a coronary stenosis can be determined by measuring the fractional flow reserve (FFR) during invasive coronary angiography. Recently, methods have been developed which claim to be able to estimate FFR using image data from standard coronary computed tomography angiography (CCTA) exams. To evaluate the accuracy of non-invasively computed fractional flow reserve (cFFR) from CCTA. A total of 23 vessels in 21 patients who had undergone both CCTA and invasive angiography with FFR measurement were evaluated using a cFFR software prototype. The cFFR results were compared to the invasively obtained FFR values. Correlation was calculated using Spearman's rank correlation, and agreement using intraclass correlation coefficient (ICC). Sensitivity, specificity, accuracy, negative predictive value, and positive predictive value for significant stenosis (defined as both FFR ≤0.80 and FFR ≤0.75) were calculated. The mean cFFR value for the whole group was 0.81 and the corresponding mean invFFR value was 0.84. The cFFR sensitivity for significant stenosis (FFR ≤0.80/0.75) on a per-lesion basis was 0.83/0.80, specificity was 0.76/0.89, and accuracy 0.78/0.87. The positive predictive value was 0.56/0.67 and the negative predictive value was 0.93/0.94. The Spearman rank correlation coefficient was ρ = 0.77 (P < 0.001) and ICC = 0.73 (P < 0.001). This particular CCTA-based cFFR software prototype allows for a rapid, non-invasive on-site evaluation of cFFR. The results are encouraging and cFFR may in the future be of help in the triage to invasive coronary angiography. © The Foundation Acta Radiologica 2015.

  12. Periodontal disease, tooth loss and coronary heart disease assessed by coronary angiography: a cross-sectional observational study.

    PubMed

    Zanella, S M; Pereira, S S; Barbisan, J N; Vieira, L; Saba-Chujfi, E; Haas, A N; Rösing, C K

    2016-04-01

    To evaluate the association between periodontal disease, tooth loss and coronary heart disease (CHD). There is still controversy about the relationship between periodontal disease and tooth loss with vessel obstruction assessed using coronary angiography. This cross-sectional study included 195 patients that underwent coronary angiography and presented with at least six teeth. Patients were classified into three categories of coronary obstruction severity: absence; one or more vessels with ≤ 50% obstruction; and one or more vessels with ≥ 50% obstruction. The extent of coronary obstruction was dichotomized into 0 and ≥ 1 affected vessels. A periodontist blinded to patient CHD status conducted a full mouth examination to determine mean clinical attachment loss, mean periodontal probing depth and tooth loss. Multiple logistic regression models were applied adjusting for age, gender, hypertension, smoking, body mass index, low-density lipoprotein cholesterol and C-reactive protein. Most patients were males (62.1%) older than 60 years (50.8%), and 61% of them had CHD. Mean periodontal probing depth, clinical attachment loss and tooth loss were 2.64 ± 0.72 mm, 4.40 ± 1.31 mm and 12.50 ± 6.98 teeth respectively. In the multivariable models, tooth loss was significantly associated with a higher chance of having at least one obstructed vessel (odds ratio = 1.04; 95% confidence interval 1.01-1.09) and with vessel obstruction ≥ 50% (odds ratio = 1.06; 95% confidence interval 1.01-1.11). No significant associations were found between periodontal variables and vessel obstruction. Tooth loss was found to be a risk indicator for CHD. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  13. Dual energy x-ray imaging and scoring of coronary calcium: physics-based digital phantom and clinical studies

    NASA Astrophysics Data System (ADS)

    Zhou, Bo; Wen, Di; Nye, Katelyn; Gilkeson, Robert C.; Wilson, David L.

    2016-03-01

    Coronary artery calcification (CAC) as assessed with CT calcium score is the best biomarker of coronary artery disease. Dual energy x-ray provides an inexpensive, low radiation-dose alternative. A two shot system (GE Revolution-XRd) is used, raw images are processed with a custom algorithm, and a coronary calcium image (DECCI) is created, similar to the bone image, but optimized for CAC visualization, not lung visualization. In this report, we developed a physicsbased, digital-phantom containing heart, lung, CAC, spine, ribs, pulmonary artery, and adipose elements, examined effects on DECCI, suggested physics-inspired algorithms to improve CAC contrast, and evaluated the correlation between CT calcium scores and a proposed DE calcium score. In simulation experiment, Beam hardening from increasing adipose thickness (2cm to 8cm) reduced Cg by 19% and 27% in 120kVp and 60kVp images, but only reduced Cg by <7% in DECCI. If a pulmonary artery moves or pulsates with blood filling between exposures, it can give rise to a significantly confounding PA signal in DECCI similar in amplitude to CAC. Observations suggest modifications to DECCI processing, which can further improve CAC contrast by a factor of 2 in clinical exams. The DE score had the best correlation with "CT mass score" among three commonly used CT scores. Results suggest that DE x-ray is a promising tool for imaging and scoring CAC, and there still remains opportunity for further DECCI processing improvements.

  14. The Coronary Artery Disease-Reporting and Data System (CAD-RADS): Prognostic and Clinical Implications Associated With Standardized Coronary Computed Tomography Angiography Reporting.

    PubMed

    Xie, Joe X; Cury, Ricardo C; Leipsic, Jonathon; Crim, Matthew T; Berman, Daniel S; Gransar, Heidi; Budoff, Matthew J; Achenbach, Stephan; Ó Hartaigh, Bríain; Callister, Tracy Q; Marques, Hugo; Rubinshtein, Ronen; Al-Mallah, Mouaz H; Andreini, Daniele; Pontone, Gianluca; Cademartiri, Filippo; Maffei, Erica; Chinnaiyan, Kavitha; Raff, Gilbert; Hadamitzky, Martin; Hausleiter, Joerg; Feuchtner, Gudrun; Dunning, Allison; DeLago, Augustin; Kim, Yong-Jin; Kaufmann, Philipp A; Villines, Todd C; Chow, Benjamin J W; Hindoyan, Niree; Gomez, Millie; Lin, Fay Y; Jones, Erica; Min, James K; Shaw, Leslee J

    2018-01-01

    This study sought to assess clinical outcomes associated with the novel Coronary Artery Disease-Reporting and Data System (CAD-RADS) scores used to standardize coronary computed tomography angiography (CTA) reporting and their potential utility in guiding post-coronary CTA care. Clinical decision support is a major focus of health care policies aimed at improving guideline-directed care. Recently, CAD-RADS was developed to standardize coronary CTA reporting and includes clinical recommendations to facilitate patient management after coronary CTA. In the multinational CONFIRM (COronary CT Angiography EvaluatioN For Clinical Outcomes: An InteRnational Multicenter) registry, 5,039 patients without known coronary artery disease (CAD) underwent coronary CTA and were stratified by CAD-RADS scores, which rank CAD stenosis severity as 0 (0%), 1 (1% to 24%), 2 (25% to 49%), 3 (50% to 69%), 4A (70% to 99% in 1 to 2 vessels), 4B (70% to 99% in 3 vessels or ≥50% left main), or 5 (100%). Kaplan-Meier and multivariable Cox models were used to estimate all-cause mortality or myocardial infarction (MI). Receiver-operating characteristic (ROC) curves were used to compare CAD-RADS to the Duke CAD Index and traditional CAD classification. Referrals to invasive coronary angiography (ICA) after coronary CTA were also assessed. Cumulative 5-year event-free survival ranged from 95.2% to 69.3% for CAD-RADS 0 to 5 (p < 0.0001). Higher scores were associated with elevations in event risk (hazard ratio: 2.46 to 6.09; p < 0.0001). The ROC curve for prediction of death or MI was 0.7052 for CAD-RADS, which was noninferior to the Duke Index (0.7073; p = 0.893) and traditional CAD classification (0.7095; p = 0.783). ICA rates were 13% for CAD-RADS 0 to 2, 66% for CAD-RADS 3, and 84% for CAD-RADS ≥4A. For CAD-RADS 3, 58% of all catheterizations occurred within the first 30 days of follow-up. In a patient subset with available medication data, 57% of CAD-RADS 3 patients who received 30

  15. An investigation of correlation between left coronary bifurcation angle and hemodynamic changes in coronary stenosis by coronary computed tomography angiography-derived computational fluid dynamics

    PubMed Central

    Chaichana, Thanapong

    2017-01-01

    Background To investigate the correlation between left coronary bifurcation angle and coronary stenosis as assessed by coronary computed tomography angiography (CCTA)-generated computational fluid dynamics (CFD) analysis when compared to the CCTA analysis of coronary lumen stenosis and plaque lesion length with invasive coronary angiography (ICA) as the reference method. Methods Thirty patients (22 males, mean age: 59±6.9 years) with calcified plaques at the left coronary artery were included in the study with all patients undergoing CCTA and ICA examinations. CFD simulation was performed to analyze hemodynamic changes to the left coronary artery models in terms of wall shear stress, wall pressure and flow velocity, with findings correlated to the coronary stenosis and degree of bifurcation angle. Calcified plaque length was measured in the left coronary artery with diagnostic value compared to that from coronary lumen and bifurcation angle assessments. Results Of 26 significant stenosis at left anterior descending (LAD) and 13 at left circumflex (LCx) on CCTA, only 14 and 5 of them were confirmed to be >50% stenosis at LAD and LCx respectively on ICA, resulting in sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of 100%, 52%, 49% and 100%. The mean plaque length was measured 5.3±3.6 and 4.4±1.9 mm at LAD and LCx, respectively, with diagnostic sensitivity, specificity, PPV and NPV being 92.8%, 46.7%, 61.9% and 87.5% for extensively calcified plaques. The mean bifurcation angle was measured 83.9±13.6º and 83.8±13.3º on CCTA and ICA, respectively, with no significant difference (P=0.98). The corresponding sensitivity, specificity, PPV and NPV were 100%, 78.6%, 84.2% and 100% based on bifurcation angle measurement on CCTA, 100%, 73.3%, 78.9% and 100% based on bifurcation angle measurements on ICA, respectively. Wall shear stress was noted to increase in the LAD and LCx models with significant stenosis and wider

  16. Transfers to metropolitan hospitals and coronary angiography for rural Aboriginal and non-Aboriginal patients with acute ischaemic heart disease in Western Australia.

    PubMed

    Lopez, Derrick; Katzenellenbogen, Judith M; Sanfilippo, Frank M; Woods, John A; Hobbs, Michael S T; Knuiman, Matthew W; Briffa, Tom G; Thompson, Peter L; Thompson, Sandra C

    2014-05-01

    Aboriginal people have a disproportionately higher incidence rate of ischaemic heart disease (IHD) than non-Aboriginal people. The findings on Aboriginal disparity in receiving coronary artery procedures are inconclusive. We describe the profile and transfers of IHD patients admitted to rural hospitals as emergency admissions and investigate determinants of transfers and coronary angiography. Person-linked hospital and mortality records were used to identify 28-day survivors of IHD events commencing at rural hospitals in Western Australia. Outcome measures were receipt of coronary angiography, transfer to a metropolitan hospital, and coronary angiography if transferred to a metropolitan hospital. Compared to non-Aboriginal patients, Aboriginal patients with IHD were more likely to be younger, have more co-morbidities, reside remotely, but less likely to have private insurance. After adjusting for demographic characteristics, Aboriginal people with MI were less likely to be transferred to a metropolitan hospital, and if transferred were less likely to receive coronary angiography. These disparities were not significant after adjusting for comorbidities and private insurance. In the full multivariate model age, comorbidities and private insurance were adversely associated with transfer to a metropolitan hospital and coronary angiography. Disparity in receiving coronary angiography following emergency admission for IHD to rural hospitals is mediated through the lower likelihood of being transferred to metropolitan hospitals where this procedure is performed. The likelihood of a transfer is increased if the patient has private insurance, however, rural Aboriginal people have a lower rate of private insurance than their non-Aboriginal counterparts. Health practitioners and policy makers can continue to claim that they treat Aboriginal and non-Aboriginal people alike based upon clinical indications, as private insurance is acting as a filter to reduce rural residents

  17. Association between smoking habits and severity of coronary stenosis as assessed by coronary computed tomography angiography.

    PubMed

    Yano, Masaya; Miura, Shin-Ichiro; Shiga, Yuhei; Miyase, Yuiko; Suematsu, Yasunori; Norimatsu, Kenji; Nakamura, Ayumi; Adachi, Sen; Nishikawa, Hiroaki; Saku, Keijiro

    2016-07-01

    Smoking promotes arteriosclerosis and is one of the most important coronary risk factors. However, few studies have investigated the association between smoking habits and the severity of coronary stenosis as assessed by coronary computed tomography angiography (CTA). We enrolled 416 patients [165/251 = smoker (past and current)/non-smoker)]. They had all undergone CTA and either were clinically suspected of having coronary artery disease (CAD) or had at least one cardiovascular risk factor. We divided the patients into smoking and non-smoking groups, and evaluated the presence of CAD, the number of significantly stenosed coronary vessels (VD), and the Gensini score as assessed by CTA in the two groups. The incidence of CAD, VD, the Gensini score, and coronary calcification score in the smoking group were all significantly greater than those in the non-smoking group (CAD, p = 0.009; VD, p = 0.003; Gensini score, p = 0.007; coronary calcification score, p = 0.01). Pack-year was significantly associated with VD and the Gensini score, and was strongly associated with multi-vessel disease (2- and 3-VD) (p < 0.05), whereas the duration of cessation in past smokers was not associated with VD or the Gensini score. Pack-year, but not the duration of cessation, may be the most important factor that was associated with the severity of coronary stenosis in terms of VD and the Gensini score.

  18. Single Center Retrospective Analysis of Conventional and Radial TIG Catheters for Transradial Diagnostic Coronary Angiography

    PubMed Central

    Vorpahl, Marc; Koehler, Till; Foerst, Jason; Panagiotopoulos, Spyridon; Schleiting, Heinrich; Koss, Klaus; Ziegler, Gunda; Brinkmann, Hilmar; Seyfarth, Melchior; Tiroch, Klaus

    2015-01-01

    Current guidelines favor the radial approach for coronary angiography. Therefore, specialty radial diagnostic catheters were designed to engage both coronary arteries with a single device. However, it is unclear if single catheters are superior to conventional catheters. A retrospective analysis was performed of consecutive right radial coronary angiographies to determine catheter use, fluoroscopy time, radiation dosage, and consumption of contrast. Procedures were performed with a single TIG catheter or conventional catheters (CONV). Procedures with coronary artery bypass grafts or ventricular angiographies were excluded. 273 transradial procedures were performed successfully. 95 procedures were performed with CONV and 178 procedures with a TIG. Crossover to additional catheters was higher in TIG (15.2%) compared to CONV (5.3%, p = 0.02). Fluoroscopy time was comparable between CONV and TIG, without crossover (2.2 ± 1.2 min versus 2.3 ± 1.2 min; n.s.), however, greater in the case of crossover for CONV (5.8 ± 0.7) and TIG (7.6 ± 3.0; p = 0.0001). Radiation dosage was similar in CONV and the TIG, without crossover (1419 ± 1075, cGy∗cm2 versus 1690 ± 1138; n.s.), however, greater for CONV (2374 ± 620) and TIG (3733 ± 2281, p = 0.05) with crossover. Overall, the amount of contrast was greater in TIG (56 ± 13 mL) versus CONV (48 ± 3 mL; p = 0.0003). CONV femoral catheters may be the primary choice for radial approach. PMID:26435876

  19. Single Center Retrospective Analysis of Conventional and Radial TIG Catheters for Transradial Diagnostic Coronary Angiography.

    PubMed

    Vorpahl, Marc; Koehler, Till; Foerst, Jason; Panagiotopoulos, Spyridon; Schleiting, Heinrich; Koss, Klaus; Ziegler, Gunda; Brinkmann, Hilmar; Seyfarth, Melchior; Tiroch, Klaus

    2015-01-01

    Current guidelines favor the radial approach for coronary angiography. Therefore, specialty radial diagnostic catheters were designed to engage both coronary arteries with a single device. However, it is unclear if single catheters are superior to conventional catheters. A retrospective analysis was performed of consecutive right radial coronary angiographies to determine catheter use, fluoroscopy time, radiation dosage, and consumption of contrast. Procedures were performed with a single TIG catheter or conventional catheters (CONV). Procedures with coronary artery bypass grafts or ventricular angiographies were excluded. 273 transradial procedures were performed successfully. 95 procedures were performed with CONV and 178 procedures with a TIG. Crossover to additional catheters was higher in TIG (15.2%) compared to CONV (5.3%, p = 0.02). Fluoroscopy time was comparable between CONV and TIG, without crossover (2.2 ± 1.2 min versus 2.3 ± 1.2 min; n.s.), however, greater in the case of crossover for CONV (5.8 ± 0.7) and TIG (7.6 ± 3.0; p = 0.0001). Radiation dosage was similar in CONV and the TIG, without crossover (1419 ± 1075, cGy∗cm(2) versus 1690 ± 1138; n.s.), however, greater for CONV (2374 ± 620) and TIG (3733 ± 2281, p = 0.05) with crossover. Overall, the amount of contrast was greater in TIG (56 ± 13 mL) versus CONV (48 ± 3 mL; p = 0.0003). CONV femoral catheters may be the primary choice for radial approach.

  20. Coronary Computed Tomography Angiography vs Functional Stress Testing for Patients With Suspected Coronary Artery Disease: A Systematic Review and Meta-analysis.

    PubMed

    Foy, Andrew J; Dhruva, Sanket S; Peterson, Brandon; Mandrola, John M; Morgan, Daniel J; Redberg, Rita F

    2017-11-01

    Coronary computed tomography angiography (CCTA) is a new approach for the diagnosis of anatomical coronary artery disease (CAD), but it is unclear how CCTA performs compared with the standard approach of functional stress testing. To compare the clinical effectiveness of CCTA with that of functional stress testing for patients with suspected CAD. A systematic literature search was conducted in PubMed and MEDLINE for English-language randomized clinical trials of CCTA published from January 1, 2000, to July 10, 2016. Researchers selected randomized clinical trials that compared a primary strategy of CCTA with that of functional stress testing for patients with suspected CAD and reported data on patient clinical events and changes in therapy. Two reviewers independently extracted data from and assessed the quality of the trials. This analysis followed the PRISMA statement for reporting systematic reviews and meta-analyses and used the Cochrane Collaboration's tool for assessing risk of bias in randomized trials. The Mantel-Haenszel method was used to conduct the primary analysis. Summary relative risks were calculated with a random-effects model. The outcomes of interest were all-cause mortality, cardiac hospitalization, myocardial infarction, invasive coronary angiography, coronary revascularization, new CAD diagnoses, and change in prescription for aspirin and statins. Thirteen trials were included, with 10 315 patients in the CCTA arm and 9777 patients in the functional stress testing arm who were followed up for a mean duration of 18 months. There were no statistically significant differences between CCTA and functional stress testing in death (1.0% vs 1.1%; risk ratio [RR], 0.93; 95% CI, 0.71-1.21) or cardiac hospitalization (2.7% vs 2.7%; RR, 0.98; 95% CI, 0.79-1.21), but CCTA was associated with a reduction in the incidence of myocardial infarction (0.7% vs 1.1%; RR, 0.71; 95% CI, 0.53-0.96). Patients undergoing CCTA were significantly more likely to undergo

  1. Effects of Peer-Facilitated, Video-Based and Combined Peer-and-Video Education on Anxiety Among Patients Undergoing Coronary Angiography: Randomised controlled trial.

    PubMed

    Habibzadeh, Hosein; Milan, Zahra D; Radfar, Moloud; Alilu, Leyla; Cund, Audrey

    2018-02-01

    Coronary angiography can be stressful for patients and anxiety-caused physiological responses during the procedure increase the risk of dysrhythmia, coronary artery spasms and rupture. This study therefore aimed to investigate the effects of peer, video and combined peer-and-video training on anxiety among patients undergoing coronary angiography. This single-blinded randomised controlled clinical trial was conducted at two large educational hospitals in Iran between April and July 2016. A total of 120 adult patients undergoing coronary angiography were recruited. Using a block randomisation method, participants were assigned to one of four groups, with those in the control group receiving no training and those in the three intervention groups receiving either peer-facilitated training, video-based training or a combination of both. A Persian-language validated version of the State-Trait Anxiety Inventory was used to measure pre- and post-intervention anxiety. There were no statistically significant differences in mean pre-intervention anxiety scores between the four groups (F = 0.31; P = 0.81). In contrast, there was a significant reduction in post-intervention anxiety among all three intervention groups compared to the control group (F = 27.71; P <0.01); however, there was no significant difference in anxiety level in terms of the type of intervention used. Peer, video and combined peer-and-video education were equally effective in reducing angiography-related patient anxiety. Such techniques are recommended to reduce anxiety amongst patients undergoing coronary angiography in hospitals in Iran.

  2. Coronary artery atherosclerosis associated with shift work in chemical plant workers by using coronary CT angiography.

    PubMed

    Kang, WonYang; Park, Won-Ju; Jang, Keun-Ho; Kim, Soo-Hyeon; Gwon, Do-Hyeong; Lim, Hyeong-Min; Ahn, Ji-Sung; Moon, Jai-Dong

    2016-08-01

    The aim of this study was to investigate whether shift work is related to elevated risk of coronary artery disease (CAD) by determining the coronary artery calcium (CAC) score and the presence of coronary artery stenosis by using coronary artery CT angiography (CCTA). In this study, 110 male workers participated and underwent a CCTA examination for CAC scoring, which represents coronary artery plaque, and were evaluated for luminal stenosis. All of the participants were working in the same chemical plant, of whom 70 worked day shifts and 40 worked rotating shifts. In a multivariate logistic regression analysis, including age, smoking status, alcohol consumption, regular exercise and waist circumference, shift work was associated with a 2.89-fold increase in the odds of developing coronary plaque compared with day work (OR, 2.89; 95% CI 1.07 to 7.82). The association between shift work and coronary plaque was strong after adjustment for age, low-density lipoprotein cholesterol, hypertension and diabetes mellitus (OR, 2.92; 95% CI 1.02 to 8.33). In addition, the number of years of shift work employment was associated with coronary plaque. However, no association was found between shift work and coronary artery stenosis. Shift work could induce CAD onset via the atherosclerotic process, and shift work employment duration was associated with an increased risk of atherosclerosis in male workers. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  3. Plaque disruption by coronary computed tomographic angiography in stable patients vs. acute coronary syndrome: a feasibility study.

    PubMed

    Bilolikar, Abhay N; Goldstein, James A; Madder, Ryan D; Chinnaiyan, Kavitha M

    2016-03-01

    This study was designed to determine whether coronary CT angiography (CTA) can detect features of plaque disruption in clinically stable patients and to compare lesion prevalence and features between stable patients and those with acute coronary syndrome (ACS). We retrospectively identified patients undergoing CTA, followed by invasive coronary angiography (ICA) within 60 days. Quantitative 3-vessel CTA lesion analysis was performed on all plaques ≥25% stenosis to assess total plaque volume, low attenuation plaque (LAP, <50 HU) volume, and remodelling index. Plaques were qualitatively assessed for CTA features of disruption, including ulceration and intra-plaque dye penetration (IDP). ICA was employed as a reference standard for disruption. A total of 145 (94 ACS and 51 stable) patients were identified. By CTA, plaque disruption was evident in 77.7% of ACS cases. Although more common among those with ACS, CTA also detected plaque disruption in 37.3% of clinically stable patients (P < 0.0001). Clinically stable patients commonly manifest plaques with features of disruption as determined by CTA. Though the prevalence of plaque disruption is less than patients with ACS, these findings support the concept that some clinically stable patients may harbour 'silent' disrupted plaques. These findings may have implications for detection of 'at risk' plaques and patients. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  4. The potential for neurovascular intravenous angiography using K-edge digital subtraction angiography

    NASA Astrophysics Data System (ADS)

    Schültke, E.; Fiedler, S.; Kelly, M.; Griebel, R.; Juurlink, B.; LeDuc, G.; Estève, F.; Le Bas, J.-F.; Renier, M.; Nemoz, C.; Meguro, K.

    2005-08-01

    Background: Catheterization of small-caliber blood vessels in the central nervous system can be extremely challenging. Alternatively, intravenous (i.v.) administration of contrast agent is minimally invasive and therefore carries a much lower risk for the patient. With conventional X-ray equipment, volumes of contrast agent that could be safely administered to the patient do not allow acquisition of high-quality images after i.v. injection, because the contrast bolus is extremely diluted by passage through the heart. However, synchrotron-based digital K-edge subtraction angiography does allow acquisition of high-quality images after i.v. administration of relatively small doses of contrast agent. Materials and methods: Eight adult male New Zealand rabbits were used for our experiments. Animals were submitted to both angiography with conventional X-ray equipment and synchrotron-based digital subtraction angiography. Results: With conventional X-ray equipment, no contrast was seen in either cerebral or spinal blood vessels after i.v. injection of iodinated contrast agent. However, using K-edge digital subtraction angiography, as little as 1 ml iodinated contrast agent, when administered as i.v. bolus, yielded images of small-caliber blood vessels in the central nervous system (both brain and spinal cord). Conclusions: If it would be possible to image blood vessels of the same diameter in the central nervous system of human patients, the synchrotron-based technique could yield high-quality images at a significantly lower risk for the patient than conventional X-ray imaging. Images could be acquired where catheterization of feeding blood vessels has proven impossible.

  5. Real-world use of fractional flow reserve in Germany: results of the prospective ALKK coronary angiography and PCI registry.

    PubMed

    Härle, Tobias; Zeymer, Uwe; Hochadel, Matthias; Zahn, Ralf; Kerber, Sebastian; Zrenner, Bernhard; Schächinger, Volker; Lauer, Bernward; Runde, Thorsten; Elsässer, Albrecht

    2017-02-01

    There is growing evidence for beneficial prognostic and economic effects of FFR-guided treatment of stable coronary artery disease. We sought to evaluate the real-world use of FFR measurements in patients undergoing elective coronary angiography. We analyzed the data of the prospective ALKK coronary angiography and PCI registry including data of 38 hospitals from January 2010 to December 2013. A total of 100,977 patients undergoing coronary angiography were included. In 3240 patients (3.2 %) intracoronary pressure measurement was performed. There was a wide range of use of FFR measurement in the different analyzed ALKK hospitals from 0.1 to 8.8 % in elective patients with suspected or known coronary artery disease (median 2.7 %, quartiles 0.9 and 5.3 %), with a successive increase of use over time during the study period. Overall, it was performed in 3.2 % of coronary angiographies. Use in patients with three-vessel disease (2.5 %) and recommendation for bypass surgery (1.6 %) was less frequent. In procedures without PCI, dose area product was higher in the FFR group (2641 cGy × cm 2 vs. 2368 cGy × cm 2 , p < 0.001), while it was lower in procedures with ad hoc PCI (4676 cGy × cm 2 vs. 5143 cGy × cm 2 , p < 0.001). The performing center turned out to be the strongest predictor. The use of FFR measurement was very heterogeneous between different hospitals and in general relatively low, in particular in patients with multivessel disease or recommendation for bypass surgery, but there was a positive trend during the study period. Technically, FFR measurement was not associated with an increased periprocedural complication rate.

  6. Computed tomography versus invasive coronary angiography: design and methods of the pragmatic randomised multicentre DISCHARGE trial.

    PubMed

    Napp, Adriane E; Haase, Robert; Laule, Michael; Schuetz, Georg M; Rief, Matthias; Dreger, Henryk; Feuchtner, Gudrun; Friedrich, Guy; Špaček, Miloslav; Suchánek, Vojtěch; Fuglsang Kofoed, Klaus; Engstroem, Thomas; Schroeder, Stephen; Drosch, Tanja; Gutberlet, Matthias; Woinke, Michael; Maurovich-Horvat, Pál; Merkely, Béla; Donnelly, Patrick; Ball, Peter; Dodd, Jonathan D; Quinn, Martin; Saba, Luca; Porcu, Maurizio; Francone, Marco; Mancone, Massimo; Erglis, Andrejs; Zvaigzne, Ligita; Jankauskas, Antanas; Sakalyte, Gintare; Harań, Tomasz; Ilnicka-Suckiel, Malgorzata; Bettencourt, Nuno; Gama-Ribeiro, Vasco; Condrea, Sebastian; Benedek, Imre; Čemerlić Adjić, Nada; Adjić, Oto; Rodriguez-Palomares, José; Garcia Del Blanco, Bruno; Roditi, Giles; Berry, Colin; Davis, Gershan; Thwaite, Erica; Knuuti, Juhani; Pietilä, Mikko; Kępka, Cezary; Kruk, Mariusz; Vidakovic, Radosav; Neskovic, Aleksandar N; Díez, Ignacio; Lecumberri, Iñigo; Geleijns, Jacob; Kubiak, Christine; Strenge-Hesse, Anke; Do, The-Hoang; Frömel, Felix; Gutiérrez-Ibarluzea, Iñaki; Benguria-Arrate, Gaizka; Keiding, Hans; Katzer, Christoph; Müller-Nordhorn, Jacqueline; Rieckmann, Nina; Walther, Mario; Schlattmann, Peter; Dewey, Marc

    2017-07-01

    More than 3.5 million invasive coronary angiographies (ICA) are performed in Europe annually. Approximately 2 million of these invasive procedures might be reduced by noninvasive tests because no coronary intervention is performed. Computed tomography (CT) is the most accurate noninvasive test for detection and exclusion of coronary artery disease (CAD). To investigate the comparative effectiveness of CT and ICA, we designed the European pragmatic multicentre DISCHARGE trial funded by the 7th Framework Programme of the European Union (EC-GA 603266). In this trial, patients with a low-to-intermediate pretest probability (10-60 %) of suspected CAD and a clinical indication for ICA because of stable chest pain will be randomised in a 1-to-1 ratio to CT or ICA. CT and ICA findings guide subsequent management decisions by the local heart teams according to current evidence and European guidelines. Major adverse cardiovascular events (MACE) defined as cardiovascular death, myocardial infarction and stroke as a composite endpoint will be the primary outcome measure. Secondary and other outcomes include cost-effectiveness, radiation exposure, health-related quality of life (HRQoL), socioeconomic status, lifestyle, adverse events related to CT/ICA, and gender differences. The DISCHARGE trial will assess the comparative effectiveness of CT and ICA. • Coronary artery disease (CAD) is a major cause of morbidity and mortality. • Invasive coronary angiography (ICA) is the reference standard for detection of CAD. • Noninvasive computed tomography angiography excludes CAD with high sensitivity. • CT may effectively reduce the approximately 2 million negative ICAs in Europe. • DISCHARGE addresses this hypothesis in patients with low-to-intermediate pretest probability for CAD.

  7. Inverse association between hyperthymic affective temperament and coronary atherosclerosis: A coronary computed tomography angiography study.

    PubMed

    Nemcsik, János; Vecsey-Nagy, Milán; Szilveszter, Bálint; Kolossváry, Márton; Karády, Júlia; László, Andrea; Kőrösi, Beáta; Nemcsik-Bencze, Zsófia; Gonda, Xénia; Merkely, Béla; Rihmer, Zoltán; Maurovich-Horvat, Pál

    2017-12-01

    A bidirectional relationship exists between psychiatric disorders and cardiovascular diseases, however less is known with regards to personality traits. Accumulating data suggest that affective temperaments are both associated with psychiatric and somatic diseases. The aim of our study was to evaluate the associations between different affective temperaments and the presence of coronary atherosclerosis. 200 consecutive patients referred to coronary computed tomography angiography (CCTA) due to suspected coronary artery disease (CAD) were included in our study. Medical history and demographic parameters were recorded and all patients completed the Temperament Evaluation of Memphis, Pisa, Paris, and San Diego Autoquestionnaire (TEMPS-A) and the Beck Depression Inventory (BDI). The presence of coronary artery disease was evaluated based on the CCTA images. 39 patients were free of any coronary atherosclerosis (CCTA-) and 161 had coronary atherosclerosis (CCTA+). Hyperthymic affective temperament score was higher in CCTA- subjects as compared to CCTA+ (13.1±3.0 vs 11.5±4.6, p=0.010, respectively). Hyperthymic affective temperament score showed a significant independent, inverse relationship with coronary atherosclerosis (OR: 0.91 CI: 0.82-0.99, p=0.04). Our results suggest that hyperthymic affective temperament is independently associated with the absence of CAD. It requires further research to delineate the mechanism mediating the effect of hyperthymia on better coronary artery health and establishing potential biochemical or behavioral factors, both of which could be exploited for prevention and treatment purposes. But it is plausible, that the evaluation of affective temperaments have importance both in relation with psychiatric and cardiovascular disorders. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Comprehensive assessment of patient image quality and radiation dose in latest generation cardiac x-ray equipment for percutaneous coronary interventions

    PubMed Central

    Gislason-Lee, Amber J.; Keeble, Claire; Egleston, Daniel; Bexon, Josephine; Kengyelics, Stephen M.; Davies, Andrew G.

    2017-01-01

    Abstract. This study aimed to determine whether a reduction in radiation dose was found for percutaneous coronary interventional (PCI) patients using a cardiac interventional x-ray system with state-of-the-art image enhancement and x-ray optimization, compared to the current generation x-ray system, and to determine the corresponding impact on clinical image quality. Patient procedure dose area product (DAP) and fluoroscopy duration of 131 PCI patient cases from each x-ray system were compared using a Wilcoxon test on median values. Significant reductions in patient dose (p≪0.001) were found for the new system with no significant change in fluoroscopy duration (p=0.2); procedure DAP reduced by 64%, fluoroscopy DAP by 51%, and “cine” acquisition DAP by 76%. The image quality of 15 patient angiograms from each x-ray system (30 total) was scored by 75 clinical professionals on a continuous scale for the ability to determine the presence and severity of stenotic lesions; image quality scores were analyzed using a two-sample t-test. Image quality was reduced by 9% (p≪0.01) for the new x-ray system. This demonstrates a substantial reduction in patient dose, from acquisition more than fluoroscopy imaging, with slightly reduced image quality, for the new x-ray system compared to the current generation system. PMID:28491907

  9. Dyspnea predicts mortality among patients undergoing coronary computed tomographic angiography.

    PubMed

    Nakanishi, Rine; Gransar, Heidi; Rozanski, Alan; Rana, Jamal S; Cheng, Victor Y; Thomson, Louise E J; Miranda-Peats, Romalisa; Dey, Damini; Hayes, Sean W; Friedman, John D; Min, James K; Berman, Daniel S

    2016-02-01

    The prognostic implications of dyspnea and typical angina in patients referred for coronary CT angiography have not been examined. We examined features associated with incident mortality risk among individuals undergoing coronary computed tomographic angiography (CCTA) presenting with dyspnea, typical angina, and neither of these symptoms. 1147 consecutive individuals without known CAD (mean 61 years, 61.6 %men) undergoing CCTA comprised the study population 132 with dyspnea, 218 with typical angina, and 797 without dyspnea or typical angina (reference group). Mortality risk in relation to dyspnea or typical angina was evaluated with multivariable Cox proportional hazards models compared to reference. In addition, the prognosis associated with dyspnea or typical angina was assessed among age matched subgroups. Patients with dyspnea had a greater prevalence of C70 % stenosis (p\\0.001) and coronary segments with plaque (p = 0.02) compared to the other two groups. During a follow-up of 3.1 years, 52 individuals died. By multivariable Cox models, compared to patients in reference group, dyspnea patients experienced higher mortality (HR 2.0, 95 % CI 1.0–4.0, p = 0.049) while typical angina patients did not (HR 1.1, 95 % CI 0.6–2.3, p = 0.76). In the matched group, the patients with dyspnea (HR 2.2, 95 % CI 1.1–4.3, p = 0.03) still had significantly reduced survival compared to the other two groups, while those with typical angina did not (HR 1.2, 95 % CI 0.6–2.6,p = 0.62). Dyspnea is associated with increased mortality ate compared to patients with typical angina and those with neither of these symptoms among patients undergoing CCTA.

  10. Learning-based automatic detection of severe coronary stenoses in CT angiographies

    NASA Astrophysics Data System (ADS)

    Melki, Imen; Cardon, Cyril; Gogin, Nicolas; Talbot, Hugues; Najman, Laurent

    2014-03-01

    3D cardiac computed tomography angiography (CCTA) is becoming a standard routine for non-invasive heart diseases diagnosis. Thanks to its high negative predictive value, CCTA is increasingly used to decide whether or not the patient should be considered for invasive angiography. However, an accurate assessment of cardiac lesions using this modality is still a time consuming task and needs a high degree of clinical expertise. Thus, providing automatic tool to assist clinicians during the diagnosis task is highly desirable. In this work, we propose a fully automatic approach for accurate severe cardiac stenoses detection. Our algorithm uses the Random Forest classi cation to detect stenotic areas. First, the classi er is trained on 18 CT cardiac exams with CTA reference standard. Then, then classi cation result is used to detect severe stenoses (with a narrowing degree higher than 50%) in a 30 cardiac CT exam database. Features that best captures the di erent stenoses con guration are extracted along the vessel centerlines at di erent scales. To ensure the accuracy against the vessel direction and scale changes, we extract features inside cylindrical patterns with variable directions and radii. Thus, we make sure that the ROIs contains only the vessel walls. The algorithm is evaluated using the Rotterdam Coronary Artery Stenoses Detection and Quantication Evaluation Framework. The evaluation is performed using reference standard quanti cations obtained from quantitative coronary angiography (QCA) and consensus reading of CTA. The obtained results show that we can reliably detect severe stenosis with a sensitivity of 64%.

  11. Optimized respiratory-resolved motion-compensated 3D Cartesian coronary MR angiography.

    PubMed

    Correia, Teresa; Ginami, Giulia; Cruz, Gastão; Neji, Radhouene; Rashid, Imran; Botnar, René M; Prieto, Claudia

    2018-04-22

    To develop a robust and efficient reconstruction framework that provides high-quality motion-compensated respiratory-resolved images from free-breathing 3D whole-heart Cartesian coronary magnetic resonance angiography (CMRA) acquisitions. Recently, XD-GRASP (eXtra-Dimensional Golden-angle RAdial Sparse Parallel MRI) was proposed to achieve 100% scan efficiency and provide respiratory-resolved 3D radial CMRA images by exploiting sparsity in the respiratory dimension. Here, a reconstruction framework for Cartesian CMRA imaging is proposed, which provides respiratory-resolved motion-compensated images by incorporating 2D beat-to-beat translational motion information to increase sparsity in the respiratory dimension. The motion information is extracted from interleaved image navigators and is also used to compensate for 2D translational motion within each respiratory phase. The proposed Optimized Respiratory-resolved Cartesian Coronary MR Angiography (XD-ORCCA) method was tested on 10 healthy subjects and 2 patients with cardiovascular disease, and compared against XD-GRASP. The proposed XD-ORCCA provides high-quality respiratory-resolved images, allowing clear visualization of the right and left coronary arteries, even for irregular breathing patterns. Compared with XD-GRASP, the proposed method improves the visibility and sharpness of both coronaries. Significant differences (p < .05) in visible vessel length and proximal vessel sharpness were found between the 2 methods. The XD-GRASP method provides good-quality images in the absence of intraphase motion. However, motion blurring is observed in XD-GRASP images for respiratory phases with larger motion amplitudes and subjects with irregular breathing patterns. A robust respiratory-resolved motion-compensated framework for Cartesian CMRA has been proposed and tested in healthy subjects and patients. The proposed XD-ORCCA provides high-quality images for all respiratory phases, independently of the regularity of

  12. Non-invasive coronary angiography with multislice computed tomography. Technology, methods, preliminary experience and prospects.

    PubMed

    Traversi, Egidio; Bertoli, Giuseppe; Barazzoni, Giancarlo; Baldi, Maurizia; Tramarin, Roberto

    2004-02-01

    The recent technical developments in multislice computed tomography (MSCT), with ECG retro-gated image reconstruction, have elicited great interest in the possibility of accurate non-invasive imaging of the coronary arteries. The latest generation of MSCT systems with 8-16 rows of detectors permits acquisition of the whole cardiac volume during a single 15-20 s breath-hold with a submillimetric definition of the images and an outstanding signal-to-noise ratio. Thus the race which, between MSCT, electron beam computed tomography and cardiac magnetic resonance imaging, can best provide routine and reliable imaging of the coronary arteries in clinical practice has recommenced. Currently available MSCT systems offer different options for both cardiac image acquisition and reconstruction, including multiplanar and curved multiplanar reconstruction, three-dimensional volume rendering, maximum intensity projection, and virtual angioscopy. In our preliminary experience including 176 patients suffering from known or suspected coronary artery disease, MSCT was feasible in 161 (91.5%) and showed a sensitivity of 80.4% and a specificity of 80.3%, with respect to standard coronary angiography, in detecting critical stenosis in coronary arteries and artery or venous bypass grafts. These results correspond to a positive predictive value of 58.6% and a negative predictive value of 92.2%. The true role that MSCT is likely to play in the future in non-invasive coronary imaging is still to be defined. Nevertheless, the huge amount of data obtainable by MSCT along with the rapid technological advances, shorter acquisition times and reconstruction algorithm developments will make the technique stronger, and possible applications are expected not only for non-invasive coronary angiography, but also for cardiac function and myocardial perfusion evaluation, as an all-in-one examination.

  13. Diagnostic yield and accuracy of coronary CT angiography after abnormal nuclear myocardial perfusion imaging.

    PubMed

    Meinel, Felix G; Schoepf, U Joseph; Townsend, Jacob C; Flowers, Brian A; Geyer, Lucas L; Ebersberger, Ullrich; Krazinski, Aleksander W; Kunz, Wolfgang G; Thierfelder, Kolja M; Baker, Deborah W; Khan, Ashan M; Fernandes, Valerian L; O'Brien, Terrence X

    2018-06-15

    We aimed to determine the diagnostic yield and accuracy of coronary CT angiography (CCTA) in patients referred for invasive coronary angiography (ICA) based on clinical concern for coronary artery disease (CAD) and an abnormal nuclear stress myocardial perfusion imaging (MPI) study. We enrolled 100 patients (84 male, mean age 59.6 ± 8.9 years) with an abnormal MPI study and subsequent referral for ICA. Each patient underwent CCTA prior to ICA. We analyzed the prevalence of potentially obstructive CAD (≥50% stenosis) on CCTA and calculated the diagnostic accuracy of ≥50% stenosis on CCTA for the detection of clinically significant CAD on ICA (defined as any ≥70% stenosis or ≥50% left main stenosis). On CCTA, 54 patients had at least one ≥50% stenosis. With ICA, 45 patients demonstrated clinically significant CAD. A positive CCTA had 100% sensitivity and 84% specificity with a 100% negative predictive value and 83% positive predictive value for clinically significant CAD on a per patient basis in MPI positive symptomatic patients. In conclusion, almost half (48%) of patients with suspected CAD and an abnormal MPI study demonstrate no obstructive CAD on CCTA.

  14. Urinary Bisphenol A Concentration and Angiography-Defined Coronary Artery Stenosis

    PubMed Central

    Melzer, David; Gates, Phil; Osborn, Nicholas J.; Henley, William E.; Cipelli, Ricardo; Young, Anita; Money, Cathryn; McCormack, Paul; Schofield, Peter; Mosedale, David; Grainger, David; Galloway, Tamara S.

    2012-01-01

    Background Bisphenol A is widely used in food and drinks packaging. There is evidence of associations between raised urinary bisphenol A (uBPA) and increased incidence of reported cardiovascular diagnoses. Methodology/Principal Findings To estimate associations between BPA exposure and angiographically graded coronary atherosclerosis. 591 patients participating in The Metabonomics and Genomics in Coronary Artery Disease (MaGiCAD) study in Cambridgeshire UK, comparing urinary BPA (uBPA) with grades of severity of coronary artery disease (CAD) on angiography. Linear models were adjusted for BMI, occupational social class and diabetes status. Severe (one to three vessel) CAD was present in 385 patients, 86 had intermediate disease (n = 86) and 120 had normal coronary arteries. The (unadjusted) median uBPA concentration was 1.28 ng/mL with normal coronary arteries, and 1.53 ng/mL with severe CAD. Compared to those with normal coronary arteries, uBPA concentration was significantly higher in those with severe CAD (OR per uBPA SD = 5.96 ng/ml OR = 1.43, CI 1.03 to 1.98, p = 0.033), and near significant for intermediate disease (OR = 1.69, CI 0.98 to 2.94, p = 0.061). There was no significant uBPA difference between patients with severe CAD (needing surgery) and the remaining groups combined. Conclusions/Significance BPA exposure was higher in those with severe coronary artery stenoses compared to those with no vessel disease. Larger studies are needed to estimate true dose response relationships. The mechanisms underlying the association remain to be established. PMID:22916252

  15. Polygamy and Risk of Coronary Artery Disease in Men Undergoing Angiography: An Observational Study

    PubMed Central

    Lotfi, Amir; Al-Murayeh, Mushabab; Al-kaabi, Salem; Al-Faifi, Salem M.; Alama, Mohamed N.; Hersi, Ahmad S.; Dixon, Ciaran M.; Ahmed, Waleed; Al-Shehri, Mohamed; Youssef, Ali; Elimam, Ahmed Moustafa; Abougalambou, Ayman S.; Murad, Waheed; Alsheikh-Ali, Alawi A.

    2017-01-01

    Epidemiologic evidence suggests a link between psychosocial risk factors such as marital status and coronary artery disease (CAD). Polygamy (multiple concurrent wives) is a distinct marital status practiced in many countries in Asia and the Middle East, but its association with CAD is not well defined. We conducted a multicenter, observational study of consecutive patients undergoing coronary angiography during the period from April 1, 2013, to March 30, 2014. Of 1,068 enrolled patients, 687 were married men. Polygamy was reported in 32% of married men (1 wife: 68%, 2 wives: 19%, 3 wives: 10%, and 4 wives: 3%). When stratified by number of wives, significant baseline differences were observed in age, type of community (rural versus urban), prior coronary artery bypass grafting (CABG), and household income. After adjusting for baseline differences, there was a significant association between polygamy and CAD (adjusted OR 4.6 [95% CI 2.5, 8.3]), multivessel disease (MVD) (adjusted OR 2.6 [95% CI 1.8, 3.7]), and left main disease (LMD) (adjusted OR 3.5 [95% CI 2.1, 5.9]). Findings were consistent when the number of wives was analyzed as a continuous variable. In conclusion, among married men undergoing coronary angiography for clinical indications, polygamy is associated with the presence of significant CAD, MVD, and LMD. PMID:28250991

  16. Polygamy and Risk of Coronary Artery Disease in Men Undergoing Angiography: An Observational Study.

    PubMed

    Daoulah, Amin; Lotfi, Amir; Al-Murayeh, Mushabab; Al-Kaabi, Salem; Al-Faifi, Salem M; Elkhateeb, Osama E; Alama, Mohamed N; Hersi, Ahmad S; Dixon, Ciaran M; Ahmed, Waleed; Al-Shehri, Mohamed; Youssef, Ali; Elimam, Ahmed Moustafa; Abougalambou, Ayman S; Murad, Waheed; Alsheikh-Ali, Alawi A

    2017-01-01

    Epidemiologic evidence suggests a link between psychosocial risk factors such as marital status and coronary artery disease (CAD). Polygamy (multiple concurrent wives) is a distinct marital status practiced in many countries in Asia and the Middle East, but its association with CAD is not well defined. We conducted a multicenter, observational study of consecutive patients undergoing coronary angiography during the period from April 1, 2013, to March 30, 2014. Of 1,068 enrolled patients, 687 were married men. Polygamy was reported in 32% of married men (1 wife: 68%, 2 wives: 19%, 3 wives: 10%, and 4 wives: 3%). When stratified by number of wives, significant baseline differences were observed in age, type of community (rural versus urban), prior coronary artery bypass grafting (CABG), and household income. After adjusting for baseline differences, there was a significant association between polygamy and CAD (adjusted OR 4.6 [95% CI 2.5, 8.3]), multivessel disease (MVD) (adjusted OR 2.6 [95% CI 1.8, 3.7]), and left main disease (LMD) (adjusted OR 3.5 [95% CI 2.1, 5.9]). Findings were consistent when the number of wives was analyzed as a continuous variable. In conclusion, among married men undergoing coronary angiography for clinical indications, polygamy is associated with the presence of significant CAD, MVD, and LMD.

  17. Thrombolysis in myocardial infarction frame count in coronary arteries without visible atherosclerosis in coronary angiography of patients with stable coronary artery disease.

    PubMed

    Tacoy, Gulten A; Yazici, Guliz E; Kocaman, Sinan A; Ozdemir, Murat H

    2009-06-01

    To investigate the thrombolysis in myocardial infarction (TIMI) frame count (TFC) in the coronary arteries without visible atherosclerosis in coronary angiography of patients with stable coronary artery disease (CAD). Eighty-three patients (mean age 58+/-10, 31 [37%] males), who underwent coronary angiographic evaluation for stable angina in Gazi University, Ankara, Turkey, Cardiology clinic between 2006-2007 were enrolled. Forty patients with normal coronary arteries were defined as group I. Group II consisted of 43 patients, who have one normal coronary artery in the setting of stable CAD defined as stenoses 50% or greater in at least one major coronary artery. Coronary blood flow and microvascular perfusion was evaluated by TFC. In group II, the TFC of left anterior descending artery (LAD) in 15 patients, TFC of circumflex artery (CX) in 18 patient, and TFC of right coronary artery (RCA) in 10 patients were evaluated. In group II, the TFC of LAD (37+/-12 versus 29+/-12, p=0.015) and CX (22+/-8 versus 18+/-9, p=0.035) were significantly higher than those in group I. The TFC of RCA was similar between groups (17+/-9 versus 17+/-8, p=0.990). After the adjustment of the risk factors by multivariate regression analyses, the association between TFC and clinical characteristic was statistically non-significant. The TFC decreased in angiographically normal LAD and CX arteries in the setting of stable angina pectoris. The important predictor was CAD alone, irrespective of the clinical parameters.

  18. Italian Chapter of the International Society of Cardiovascular Ultrasound expert consensus document on coronary computed tomography angiography: overview and new insights.

    PubMed

    Sozzi, Fabiola B; Maiello, Maria; Pelliccia, Francesco; Parato, Vito Maurizio; Canetta, Ciro; Savino, Ketty; Lombardi, Federico; Palmiero, Pasquale

    2016-09-01

    Coronary computed tomography angiography is a noninvasive heart imaging test currently undergoing rapid development and advancement. The high resolution of the three-dimensional pictures of the moving heart and great vessels is performed during a coronary computed tomography to identify coronary artery disease and classify patient risk for atherosclerotic cardiovascular disease. The technique provides useful information about the coronary tree and atherosclerotic plaques beyond simple luminal narrowing and plaque type defined by calcium content. This application will improve image-guided prevention, medical therapy, and coronary interventions. The ability to interpret coronary computed tomography images is of utmost importance as we develop personalized medical care to enable therapeutic interventions stratified on the bases of plaque characteristics. This overview provides available data and expert's recommendations in the utilization of coronary computed tomography findings. We focus on the use of coronary computed tomography to detect coronary artery disease and stratify patients at risk, illustrating the implications of this test on patient management. We describe its diagnostic power in identifying patients at higher risk to develop acute coronary syndrome and its prognostic significance. Finally, we highlight the features of the vulnerable plaques imaged by coronary computed tomography angiography. © 2016, Wiley Periodicals, Inc.

  19. CAD-RADS - a new clinical decision support tool for coronary computed tomography angiography.

    PubMed

    Foldyna, Borek; Szilveszter, Bálint; Scholtz, Jan-Erik; Banerji, Dahlia; Maurovich-Horvat, Pál; Hoffmann, Udo

    2018-04-01

    Coronary computed tomography angiography (CTA) has been established as an accurate method to non-invasively assess coronary artery disease (CAD). The proposed 'Coronary Artery Disease Reporting and Data System' (CAD-RADS) may enable standardised reporting of the broad spectrum of coronary CTA findings related to the presence, extent and composition of coronary atherosclerosis. The CAD-RADS classification is a comprehensive tool for summarising findings on a per-patient-basis dependent on the highest-grade coronary artery lesion, ranging from CAD-RADS 0 (absence of CAD) to CAD-RADS 5 (total occlusion of a coronary artery). In addition, it provides suggestions for clinical management for each classification, including further testing and therapeutic options. Despite some limitations, CAD-RADS may facilitate improved communication between imagers and patient caregivers. As such, CAD-RADS may enable a more efficient use of coronary CTA leading to more accurate utilisation of invasive coronary angiograms. Furthermore, widespread use of CAD-RADS may facilitate registry-based research of diagnostic and prognostic aspects of CTA. • CAD-RADS is a tool for standardising coronary CTA reports. • CAD-RADS includes clinical treatment recommendations based on CTA findings. • CAD-RADS has the potential to reduce variability of CTA reports.

  20. The effect of reflexotherapy and massage therapy on vital signs and stress before coronary angiography: An open-label clinical trial.

    PubMed

    Khaledifar, Ali; Nasiri, Marzeih; Khaledifar, Borzoo; Khaledifar, Arsalan; Mokhtari, Ali

    2017-03-01

    Complementary medicine interventions are now successfully used to reduce stress as well as to stabilize hemodynamic indices within different procedures. The present study aimed to examine the effect of massage therapy and reflexotherapy on reducing stress in patients before coronary angiography. In this open-label clinical trial, 75 consecutive patients who were candidate for coronary angiography were randomly assigned to receive reflexotherapy (n = 25), or massage therapy (n = 25), or routine care (n = 25) before angiography. The Spielberger State-Trait Anxiety Inventory was used to determine the stress level of patients before and after interventions and vital signs were also measured. Improvement in diastolic blood pressure, heart rate, and respiratory rate was shown in the reflexotherapy group, and similar effects were observed following other interventions including massage therapy and routine resting program. In subjects who received reflexotherapy the level of stress decreased slightly compared with the other two groups. However, following interventions the level of stress in reflexotherapy group was shown to be lower than other study groups. Reflexotherapy before coronary angiography can help to stabilize vital sign as well as reduce the level of stress. The effect of massage therapy was limited to reducing stress.

  1. Long-term major adverse cardiovascular events and quality of life after coronary angiography in elderly patients with acute coronary syndrome.

    PubMed

    Sigurjonsdottir, R; Barywani, S; Albertsson, P; Fu, M

    2016-11-01

    Although the elderly comprise the majority of acute coronary syndrome (ACS) patients, limited data exist on major adverse cardiovascular events (MACEs) and quality of life (QoL). To study MACEs and QoL prospectively in ACS patients >70years referred for coronary angiography. A prospective observational study that included ACS patients >70years undergoing coronary angiography. The outcomes were MACEs and QoL 3years after inclusion. MACEs were defined as death, recurrent ACS, new-onset of heart failure and repeated revascularization by coronary artery bypass grafting (CABG) or percutaneous coronary intervention (PCI). A QoL questionnaire was completed by the patients along with a physical examination and a personal interview at the 3-year follow-up. Multivariate analysis was performed to identify the predictors for MACEs. In total, 138 patients (mean age 78.8±3.8years) with ACS were included in the study. Mean follow-up was 1196±296days. In all, 42% of the patients had MACEs and 25% had post-ACS heart failure. The mortality rate was 11%. After adjusting for significant cardiovascular risk factors, the following factors were significantly associated with MACEs: Age, high-sensitive troponin T (hsTNT), use of diuretics and reduced left ventricular ejection fraction (LVEF). Furthermore, the QoL evaluated with SF-36 in survivors from ACS at the end of study was similar to the QoL in an age-matched healthy Swedish population. In this prospective study on elderly ACS patients MACEs still occurred in 42% of the cases (despite low mortality and good QoL), with post-ACS heart failure as the most important event. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  2. Comparison of Head Elevation Protocols Following Femoral Artery Sheath Removal After Coronary Angiography.

    PubMed

    Olson, Nancy C

    2016-06-01

    To compare 2 standard protocols for head elevation following removal of a femoral artery sheath after coronary angiography and their effects on bleeding complications and reported levels of back pain. One protocol involved flat supine bed rest; the other allowed progressive head elevation. A prospective comparative study of 80 adult patients undergoing coronary angiography via the femoral approach. The Numeric Rating Scale was used as the measure of reported pain. No bleeding complications occurred in either group. Both groups had very low mean pain scores. Repeated-measures analysis demonstrated that the experience of pain differed significantly over time by location (F5,70 = 3.864, P = .004), with a notable decrease in pain scores more than 1 hour after sheath removal at the location that used the progressive head elevation protocol. Patients' satisfaction scores after discharge did not differ significantly between the 2 groups. Patients with a history of chronic back pain had consistently higher pain scores, but those pain scores did not differ significantly by location (or protocol). It appears that using a progressive head-elevation protocol within the first 3 hours after diagnostic angiography is not associated with an increased risk of bleeding complications at the access site and warrants further exploration in the mitigation of back pain associated with prolonged supine bed rest. ©2016 American Association of Critical-Care Nurses.

  3. Reduction of the estimated radiation dose and associated patient risk with prospective ECG-gated 256-slice CT coronary angiography

    NASA Astrophysics Data System (ADS)

    Efstathopoulos, E. P.; Kelekis, N. L.; Pantos, I.; Brountzos, E.; Argentos, S.; Grebáč, J.; Ziaka, D.; Katritsis, D. G.; Seimenis, I.

    2009-09-01

    Computed tomography (CT) coronary angiography has been widely used since the introduction of 64-slice scanners and dual-source CT technology, but high radiation doses have been reported. Prospective ECG-gating using a 'step-and-shoot' axial scanning protocol has been shown to reduce radiation exposure effectively while maintaining diagnostic accuracy. 256-slice scanners with 80 mm detector coverage have been currently introduced into practice, but their impact on radiation exposure has not been adequately studied. The aim of this study was to assess radiation doses associated with CT coronary angiography using a 256-slice CT scanner. Radiation doses were estimated for 25 patients scanned with either prospective or retrospective ECG-gating. Image quality was assessed objectively in terms of mean CT attenuation at selected regions of interest on axial coronary images and subjectively by coronary segment quality scoring. It was found that radiation doses associated with prospective ECG-gating were significantly lower than retrospective ECG-gating (3.2 ± 0.6 mSv versus 13.4 ± 2.7 mSv). Consequently, the radiogenic fatal cancer risk for the patient is much lower with prospective gating (0.0176% versus 0.0737%). No statistically significant differences in image quality were observed between the two scanning protocols for both objective and subjective quality assessments. Therefore, prospective ECG-gating using a 'step-and-shoot' protocol that covers the cardiac anatomy in two axial acquisitions effectively reduces radiation doses in 256-slice CT coronary angiography without compromising image quality.

  4. Congenital Anomaly of Single Dominant Right Coronary Artery with Hypoplastic Left Coronary Artery.

    PubMed

    Chuang, Cheng-Yen; Chen, Yen-Chou; Cheng, Ho-Shun; Hsieh, Ming-Hsiung

    2015-11-01

    With the popularization of new imaging technology, more people are deciding to undergo non-invasive studies such as multidetector computerized tomography (MDCT) before receiving coronary angiography. For this reason, coronary anomalies of coronary artery are being encountered more frequently. We here report a 68-year-old male presenting with typical angina. The MDCT images suggested chronic total occlusion of the left anterior descending (LAD) artery with collateral circulation from the right coronary artery (RCA). The patient's coronary angiography showed a congenital coronary anomaly with a single dominant RCA supplying the entire coronary circulation of the heart with both LAD and left circumflex artery hypoplasia. Angiography; Anomaly; Computerized tomography; Coronary artery.

  5. Effects of Hyperthyroidism on Coronary Artery Disease: A Computed Tomography Angiography Study.

    PubMed

    Beyer, Christoph; Plank, Fabian; Friedrich, Guy; Wildauer, Matthias; Feuchtner, Gudrun

    2017-10-01

    Changes in thyroid hormone concentration can negatively affect the cardiovascular system. Subclinical hyperthyroidism has been linked to an increase of cardiovascular heart disease, however, clinical effects and significance are still uncertain. Therefore, we analyzed coronary computed tomography angiographies of patients with overt and subclinical hyperthyroidism for quantitative parameters and plaque morphology. Seven hundred forty-four (47.1% female) patients who underwent coronary computed tomography angiography were stratified into 3 groups: 51 patients with overt, 74 patients with subclinical hyperthyroidism, and 619 patients with euthyroidism. Analysis included grades of stenosis (no stenosis = 0, mild < 50%, intermediate 50%-70%, or high-grade > 70%) and plaque types (noncalcified, mixed, and calcified), segment involvement score (SIS), noncalcified SIS, and high-risk plaque features (napkin ring sign, low attenuation plaque, spotty calcifications, positive remodelling). Patients with overt and subclinical hyperthyroidism had more high-grade stenoses (39.2% vs 37.8% vs 24.2%; P = 0.007) and a higher coronary calcium score (456.5 vs 199.5 vs 155.9; P < 0.0001). Also, a total higher plaque burden has been found (SIS: 3.3 vs 3.2 vs 2.2; P < 0.0001; noncalcified SIS (1.2 vs 1.1 vs 0.6; P < 0.0001)). Patients with overt hyperthyroidism, followed by those with subclinical hyperthyroidism, had the most high-risk plaque features: napkin ring (21.6% vs 9.5% vs 6.0%, P < 0.0001), low attenuation plaque (35.3% vs 27% vs 8.7%, P < 0.0001), spotty calcification (35.3% vs 18.9% vs 19.1%, P = 0.02), and positive remodelling (37.3% vs 37.8% vs 25.5%, P = 0.02). After a mean follow-up of 168 months, significantly more revascularizations were documented for hyperthyroid patients. Patients with subclinical and overt hyperthyroidism showed more high-grade coronary stenoses, plaque burden, and high-risk plaque features than patients with euthyroidism, which indicates that

  6. Subtraction coronary CT angiography using second-generation 320-detector row CT.

    PubMed

    Yoshioka, Kunihiro; Tanaka, Ryoichi; Muranaka, Kenta; Sasaki, Tadashi; Ueda, Takanori; Chiba, Takuya; Takeda, Kouta; Sugawara, Tsuyoshi

    2015-06-01

    The purpose of this study was to explore the feasibility of subtraction coronary computed tomography angiography (CCTA) by second-generation 320-detector row CT in patients with severe coronary artery calcification using invasive coronary angiography (ICA) as the gold standard. This study was approved by the institutional board, and all subjects provided written consent. Twenty patients with calcium scores of >400 underwent conventional CCTA and subtraction CCTA followed by ICA. A total of 82 segments were evaluated for image quality using a 4-point scale and the presence of significant (>50 %) luminal stenosis by two independent readers. The average image quality was 2.3 ± 0.8 with conventional CCTA and 3.2 ± 0.6 with subtraction CCTA (P < 0.001). The percentage of segments with non-diagnostic image quality was 43.9 % on conventional CCTA versus 8.5 % on subtraction CCTA (P = 0.004). The segment-based diagnostic accuracy for detecting significant stenosis according to ICA revealed an area under the receiver operating characteristics curve of 0.824 (95 % confidence interval [CI], 0.750-0.899) for conventional CCTA and 0.936 (95 % CI 0.889-0.936) for subtraction CCTA (P = 0.001). The sensitivity, specificity, positive predictive value, and negative predictive value for conventional CCTA were 88.2, 62.5, 62.5, and 88.2 %, respectively, and for subtraction CCTA they were 94.1, 85.4, 82.1, and 95.3 %, respectively. As compared to conventional, subtraction CCTA using a second-generation 320-detector row CT showed improvement in diagnostic accuracy at segment base analysis in patients with severe calcifications.

  7. Myocardial segmentation based on coronary anatomy using coronary computed tomography angiography: Development and validation in a pig model.

    PubMed

    Chung, Mi Sun; Yang, Dong Hyun; Kim, Young-Hak; Kang, Soo-Jin; Jung, Joonho; Kim, Namkug; Heo, Seung-Ho; Baek, Seunghee; Seo, Joon Beom; Choi, Byoung Wook; Kang, Joon-Won; Lim, Tae-Hwan

    2017-10-01

    To validate a method for performing myocardial segmentation based on coronary anatomy using coronary CT angiography (CCTA). Coronary artery-based myocardial segmentation (CAMS) was developed for use with CCTA. To validate and compare this method with the conventional American Heart Association (AHA) classification, a single coronary occlusion model was prepared and validated using six pigs. The unstained occluded coronary territories of the specimens and corresponding arterial territories from CAMS and AHA segmentations were compared using slice-by-slice matching and 100 virtual myocardial columns. CAMS more precisely predicted ischaemic area than the AHA method, as indicated by 95% versus 76% (p < 0.001) of the percentage of matched columns (defined as percentage of matched columns of segmentation method divided by number of unstained columns in the specimen). According to the subgroup analyses, CAMS demonstrated a higher percentage of matched columns than the AHA method in the left anterior descending artery (100% vs. 77%; p < 0.001) and mid- (99% vs. 83%; p = 0.046) and apical-level territories of the left ventricle (90% vs. 52%; p = 0.011). CAMS is a feasible method for identifying the corresponding myocardial territories of the coronary arteries using CCTA. • CAMS is a feasible method for identifying corresponding coronary territory using CTA • CAMS is more accurate in predicting coronary territory than the AHA method • The AHA method may underestimate the ischaemic territory of LAD stenosis.

  8. Cohort profile: the Coronary Artery disease Risk Determination In Innsbruck by diaGnostic ANgiography (CARDIIGAN) cohort

    PubMed Central

    Wanitschek, Maria; Edlinger, Michael; Dörler, Jakob; Alber, Hannes F

    2018-01-01

    Purpose The Coronary Artery disease Risk Determination In Innsbruck by diaGnostic ANgiography (CARDIIGAN) cohort is aimed to gain a better understanding of cardiovascular risk factors and their relation to the diagnosis and severity of coronary artery disease, as well as to the long-term prognosis in consecutive (including revascularised) patients referred for elective coronary angiography. Participants The included patients visited the University Clinic of Cardiology at Innsbruck (Austria), which fulfils a secondary and tertiary hospital function. Inclusion took place in the period between February 2004 and April 2008 and resulted in a total of 8296 patients aged 18–91 years; 65% of them were men. Findings to date There was one follow-up round on vital status through record linkage for 84% of the cohort (those with residence in Tyrol), resulting in a follow-up duration of over 5.5 to nearly 10.0 years among survivors. The data contain basic patient characteristics, cardiovascular risk factors, laboratory measurements, medications, detailed information on the extent and severity of coronary artery disease, revascularisation history, treatment strategy and mortality specifics. A few studies have already been published. Future plans Various diagnostic and prognostic studies are planned, also concerning complications, competing risks and cost-effectiveness. Collaboration with other research groups is welcomed. PMID:29880572

  9. Early biomarkers of acute kidney failure after heart angiography or heart surgery in patients with acute coronary syndrome or acute heart failure.

    PubMed

    Torregrosa, Isidro; Montoliu, Carmina; Urios, Amparo; Elmlili, Nisrin; Puchades, María Jesús; Solís, Miguel Angel; Sanjuán, Rafael; Blasco, Maria Luisa; Ramos, Carmen; Tomás, Patricia; Ribes, José; Carratalá, Arturo; Juan, Isabel; Miguel, Alfonso

    2012-01-01

    Acute kidney injury (AKI) is a common complication in cardiac surgery and coronary angiography, which worsens patients' prognosis. The diagnosis is based on the increase in serum creatinine, which is delayed. It is necessary to identify and validate new biomarkers that allow for early and effective interventions. To assess the sensitivity and specificity of neutrophil gelatinase-associated lipocalin in urine (uNGAL), interleukin-18 (IL-18) in urine and cystatin C in serum for the early detection of AKI in patients with acute coronary syndrome or heart failure, and who underwent cardiac surgery or catheterization. The study included 135 patients admitted to the intensive care unit for acute coronary syndrome or heart failure due to coronary or valvular pathology and who underwent coronary angiography or cardiac bypass surgery or valvular replacement. The biomarkers were determined 12 hours after surgery and serum creatinine was monitored during the next six days for the diagnosis of AKI. The area under the ROC curve (AUC) for NGAL was 0.983, and for cystatin C and IL-18 the AUCs were 0.869 and 0.727, respectively. At a cut-off of 31.9 ng/ml for uNGAL the sensitivity was 100% and the specificity was 91%. uNGAL is an early marker of AKI in patients with acute coronary syndrome or heart failure and undergoing cardiac surgery and coronary angiography, with a higher predictive value than cystatin C or IL-18.

  10. Differences in coronary plaque composition with aging measured by coronary computed tomography angiography.

    PubMed

    Tota-Maharaj, Rajesh; Blaha, Michael J; Rivera, Juan J; Henry, Travis S; Choi, Eue-Keun; Chang, Sung-A; Yoon, Yeonyee E; Chun, Eun Ju; Choi, Sang-Il; Blumenthal, Roger S; Chang, Hyuk-Jae; Nasir, Khurram

    2012-07-12

    Little is known about the independent impact of aging on coronary plaque morphology and composition in the era of cardiac computed tomography angiography (CCTA). We studied 1015 consecutive asymptomatic South Korean subjects (49 ± 10 years, 64% men) who underwent 64-slice CCTA during routine health evaluation. Coronary plaque characteristics were analyzed on a per-segment basis according to the modified AHA classification. Plaques with >50% calcified tissue were classified as calcified (CAP), plaques with <50% calcified tissue were classified as mixed (MCAP), and plaques without calcium were classified as non-calcified (NCAP). Multiple regression analysis was employed to describe the cross-sectional association between age tertile and plaque type burden (≥ 2 affected segments) after adjustment for other cardiovascular risk factors. The prevalence of coronary plaque increased with age, (1st tertile: 7.5%, 3rd tertile: 38.5% [p<0.001]). The relative contribution of NCAP to overall plaque burden decreased with age from nearly 50% in the first tertile to approximately 20% in the third, while there was a reciprocal increase in both MCAP and CAP subtypes. In multivariable analysis, patients in the oldest tertile had a 2.5-fold increase in burden of NCAP, yet a nearly 40-fold increase in MCAP and 16-fold increase in CAP compared to the youngest tertile. In conclusion, CCTA is an effective method for measuring age-related differences in the burden of individual coronary plaque subtypes. Future research is needed to determine whether the increase in mixed and calcified plaques seen with aging produce an independent contribution to the age-related increase in cardiovascular risk. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  11. Evaluation of Coronary Artery Stenosis by Quantitative Flow Ratio During Invasive Coronary Angiography: The WIFI II Study (Wire-Free Functional Imaging II).

    PubMed

    Westra, Jelmer; Tu, Shengxian; Winther, Simon; Nissen, Louise; Vestergaard, Mai-Britt; Andersen, Birgitte Krogsgaard; Holck, Emil Nielsen; Fox Maule, Camilla; Johansen, Jane Kirk; Andreasen, Lene Nyhus; Simonsen, Jo Krogsgaard; Zhang, Yimin; Kristensen, Steen Dalby; Maeng, Michael; Kaltoft, Anne; Terkelsen, Christian Juhl; Krusell, Lars Romer; Jakobsen, Lars; Reiber, Johan H C; Lassen, Jens Flensted; Bøttcher, Morten; Bøtker, Hans Erik; Christiansen, Evald Høj; Holm, Niels Ramsing

    2018-03-01

    Quantitative flow ratio (QFR) is a novel diagnostic modality for functional testing of coronary artery stenosis without the use of pressure wires and induction of hyperemia. QFR is based on computation of standard invasive coronary angiographic imaging. The purpose of WIFI II (Wire-Free Functional Imaging II) was to evaluate the feasibility and diagnostic performance of QFR in unselected consecutive patients. WIFI II was a predefined substudy to the Dan-NICAD study (Danish Study of Non-Invasive Diagnostic Testing in Coronary Artery Disease), referring 362 consecutive patients with suspected coronary artery disease on coronary computed tomographic angiography for diagnostic invasive coronary angiography. Fractional flow reserve (FFR) was measured in all segments with 30% to 90% diameter stenosis. Blinded observers calculated QFR (Medis Medical Imaging bv, The Netherlands) for comparison with FFR. FFR was measured in 292 lesions from 191 patients. Ten (5%) and 9 patients (5%) were excluded because of FFR and angiographic core laboratory criteria, respectively. QFR was successfully computed in 240 out of 255 lesions (94%) with a mean diameter stenosis of 50±12%. Mean difference between FFR and QFR was 0.01±0.08. QFR correctly classified 83% of the lesions using FFR with cutoff at 0.80 as reference standard. The area under the receiver operating characteristic curve was 0.86 (95% confidence interval, 0.81-0.91) with a sensitivity, specificity, negative predictive value, and positive predictive value of 77%, 86%, 75%, and 87%, respectively. A QFR-FFR hybrid approach based on the present results enables wire-free and adenosine-free procedures in 68% of cases. Functional lesion evaluation by QFR assessment showed good agreement and diagnostic accuracy compared with FFR. Studies comparing clinical outcome after QFR- and FFR-based diagnostic strategies are required. URL: https://www.clinicaltrials.gov. Unique identifier: NCT02264717. © 2018 The Authors.

  12. Observer variability in the assessment of CT coronary angiography and coronary artery calcium score: substudy of the Scottish COmputed Tomography of the HEART (SCOT-HEART) trial

    PubMed Central

    Williams, Michelle C; Golay, Saroj K; Hunter, Amanda; Weir-McCall, Jonathan R; Mlynska, Lucja; Dweck, Marc R; Uren, Neal G; Reid, John H; Lewis, Steff C; Berry, Colin; van Beek, Edwin J R; Roditi, Giles; Newby, David E; Mirsadraee, Saeed

    2015-01-01

    Introduction Observer variability can influence the assessment of CT coronary angiography (CTCA) and the subsequent diagnosis of angina pectoris due to coronary heart disease. Methods We assessed 210 CTCAs from the Scottish COmputed Tomography of the HEART (SCOT-HEART) trial for intraobserver and interobserver variability. Calcium score, coronary angiography and image quality were evaluated. Coronary artery disease was defined as none (<10%), mild (10–49%), moderate (50–70%) and severe (>70%) luminal stenosis and classified as no (<10%), non-obstructive (10–70%) or obstructive (>70%) coronary artery disease. Post-CTCA diagnosis of angina pectoris due to coronary heart disease was classified as yes, probable, unlikely or no. Results Patients had a mean body mass index of 29 (28, 30) kg/m2, heart rate of 58 (57, 60)/min and 62% were men. Intraobserver and interobserver agreements for the presence or absence of coronary artery disease were excellent (95% agreement, κ 0.884 (0.817 to 0.951) and good (91%, 0.791 (0.703 to 0.879)). Intraobserver and interobserver agreement for the presence or absence of angina pectoris due to coronary heart disease were excellent (93%, 0.842 (0.918 to 0.755) and good (86%, 0.701 (0.799 to 0.603)), respectively. Observer variability of calcium score was excellent for calcium scores below 1000. More segments were categorised as uninterpretable with 64-multidetector compared to 320-multidetector CTCA (10.1% vs 2.6%, p<0.001) but there was no difference in observer variability. Conclusions Multicentre multidetector CTCA has excellent agreement in patients under investigation for suspected angina due to coronary heart disease. Trial registration number NCT01149590. PMID:26019881

  13. Diagnostic Accuracy of Computed Tomography Angiography as Compared to Conventional Angiography in Patients Undergoing Noncoronary Cardiac Surgery

    PubMed Central

    Joshi, Hasit; Shah, Ronak; Prajapati, Jayesh; Bhangdiya, Vipin; Shah, Jayal; Kandre, Yogini; Shah, Komal

    2016-01-01

    Objective: To compare the diagnostic accuracy of multi-slice computed tomography (MSCT) angiography with conventional angiography in patients undergoing major noncoronary cardiac surgeries. Materials and Methods: We studied fifty major noncoronary cardiac surgery patients scheduled for invasive coronary angiography, 29 (58%) female and 21 (42%) male. Inclusion criteria of the study were age of the patients ≥40 years, having low or intermediate probability of coronary artery disease (CAD), left ventricular ejection fraction (LVEF) >35%, and patient giving informed consent for undergoing MSCT and conventional coronary angiography. The patients with LVEF <35%, high pretest probability of CAD, and hemodynamically unstable were excluded from the study. Results: The diagnostic accuracy of CT coronary angiography was evaluated regarding true positive, true negative values. The overall sensitivity and specificity of CT angiography technique was 100% (95% confidence interval [CI]: 39.76%–100%) and 91.30% (95% CI: 79.21%–97.58%). The positive (50%; 95% CI: 15.70%–84.30%) and negative predictive values (100%; 95% CI: 91.59%–100%) of CT angiography were also fairly high in these patients. Conclusion: Our study suggests that this non-invasive technique may improve perioperative risk stratification in patients undegoing non-cardiac surgery. PMID:27867455

  14. Four-Dimensional Respiratory Motion-Resolved Whole Heart Coronary MR Angiography

    PubMed Central

    Piccini, Davide; Feng, Li; Bonanno, Gabriele; Coppo, Simone; Yerly, Jérôme; Lim, Ruth P.; Schwitter, Juerg; Sodickson, Daniel K.; Otazo, Ricardo; Stuber, Matthias

    2016-01-01

    Purpose Free-breathing whole-heart coronary MR angiography (MRA) commonly uses navigators to gate respiratory motion, resulting in lengthy and unpredictable acquisition times. Conversely, self-navigation has 100% scan efficiency, but requires motion correction over a broad range of respiratory displacements, which may introduce image artifacts. We propose replacing navigators and self-navigation with a respiratory motion-resolved reconstruction approach. Methods Using a respiratory signal extracted directly from the imaging data, individual signal-readouts are binned according to their respiratory states. The resultant series of undersampled images are reconstructed using an extradimensional golden-angle radial sparse parallel imaging (XD-GRASP) algorithm, which exploits sparsity along the respiratory dimension. Whole-heart coronary MRA was performed in 11 volunteers and four patients with the proposed methodology. Image quality was compared with that obtained with one-dimensional respiratory self-navigation. Results Respiratory-resolved reconstruction effectively suppressed respiratory motion artifacts. The quality score for XD-GRASP reconstructions was greater than or equal to self-navigation in 80/88 coronary segments, reaching diagnostic quality in 61/88 segments versus 41/88. Coronary sharpness and length were always superior for the respiratory-resolved datasets, reaching statistical significance (P < 0.05) in most cases. Conclusion XD-GRASP represents an attractive alternative for handling respiratory motion in free-breathing whole heart MRI and provides an effective alternative to self-navigation. PMID:27052418

  15. Prevalence and risk factors of premature coronary artery disease in patients undergoing coronary angiography in Kurdistan, Iraq.

    PubMed

    Mohammad, Ameen Mosa; Jehangeer, Hekmat Izzat; Shaikhow, Sabri Khalif

    2015-11-18

    Premature coronary artery disease (PCAD) seems to increase, particularly in developing countries. Given the lack of such studies in the country, this study examines the prevalence, associated cardiovascular risk factors, and coronary angiographic profile of the disease in Iraq. Data was collected from a total of 445 adult patients undergoing coronary angiography at Duhok Heart Center, Kurdistan in a period between March and September 2014. Patients were divided into PCAD (male <45 years and female < 55 years) and mature coronary artery disease (MCAD). The prevalence of the angiographically documented PCAD was 31 %. The PCAD had higher rates of hyperlipidemia (p = 0.04), positive family history of coronary artery disease (p = 0.002), type A lesions (p = 0.02), single vessel disease (p = 0.01) and medical treatment (p = 0.01) than the MCAD. Logistic regression model indicated that male sex (OR 3.38, C.I 1.96-7.22), smoking (OR 2.08, C.I 1.05-4.12), hypertension (OR 1.58, C.I 1.25-2.03), hyperlipidemia (OR 1.89, C.I 1.17-2.42) and positive family history of coronary artery disease (OR 2.62, C.I 1.38-9.54) were associated with the PCAD. Sensitivity analysis showed highest specificity (94.2 %) and positive predictive value (96.5 %) in patients with coronary stenosis >70 % compared to lesser obstruction. Premature coronary artery disease is alarming  in the country. Cardiovascular risk factors are clustered among them. But the angiographic profile and therapeutic options of PCAD are close to those reported from previous studies.

  16. Establishing a successful coronary CT angiography program in the emergency department: official writing of the Fellow and Resident Leaders of the Society of Cardiovascular Computed Tomography (FiRST).

    PubMed

    Maroules, Christopher D; Blaha, Michael J; El-Haddad, Mohamed A; Ferencik, Maros; Cury, Ricardo C

    2013-01-01

    Coronary CT angiography is an effective, evidence-based strategy for evaluating acute chest pain in the emergency department for patients at low-to-intermediate risk of acute coronary syndrome. Recent multicenter trials have reported that coronary CT angiography is safe, reduces time to diagnosis, facilitates discharge, and may lower overall cost compared with routine care. Herein, we provide a 10-step approach for establishing a successful coronary CT angiography program in the emergency department. The importance of strategic planning and multidisciplinary collaboration is emphasized. Patient selection and preparation guidelines for coronary CT angiography are reviewed with straightforward protocols that can be adapted and modified to clinical sites, depending on available cardiac imaging capabilities. Technical parameters and patient-specific modifications are also highlighted to maximize the likelihood of diagnostic quality examinations. Practical suggestions for quality control, process monitoring, and standardized reporting are reviewed. Finally, the role of a "triple rule-out" protocol is featured in the context of acute chest pain evaluation in the emergency department. Copyright © 2013 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

  17. Prognostic value of coronary computed tomographic angiography findings in asymptomatic individuals: a 6-year follow-up from the prospective multicentre international CONFIRM study.

    PubMed

    Cho, Iksung; Al'Aref, Subhi J; Berger, Adam; Ó Hartaigh, Bríain; Gransar, Heidi; Valenti, Valentina; Lin, Fay Y; Achenbach, Stephan; Berman, Daniel S; Budoff, Matthew J; Callister, Tracy Q; Al-Mallah, Mouaz H; Cademartiri, Filippo; Chinnaiyan, Kavitha; Chow, Benjamin J W; DeLago, Augustin; Villines, Todd C; Hadamitzky, Martin; Hausleiter, Joerg; Leipsic, Jonathon; Shaw, Leslee J; Kaufmann, Philipp A; Feuchtner, Gudrun; Kim, Yong-Jin; Maffei, Erica; Raff, Gilbert; Pontone, Gianluca; Andreini, Daniele; Marques, Hugo; Rubinshtein, Ronen; Chang, Hyuk-Jae; Min, James K

    2018-03-14

    The long-term prognostic benefit of coronary computed tomographic angiography (CCTA) findings of coronary artery disease (CAD) in asymptomatic populations is unknown. From the prospective multicentre international CONFIRM long-term study, we evaluated asymptomatic subjects without known CAD who underwent both coronary artery calcium scoring (CACS) and CCTA (n = 1226). Coronary computed tomographic angiography findings included the severity of coronary artery stenosis, plaque composition, and coronary segment location. Using the C-statistic and likelihood ratio tests, we evaluated the incremental prognostic utility of CCTA findings over a base model that included a panel of traditional risk factors (RFs) as well as CACS to predict long-term all-cause mortality. During a mean follow-up of 5.9 ± 1.2 years, 78 deaths occurred. Compared with the traditional RF alone (C-statistic 0.64), CCTA findings including coronary stenosis severity, plaque composition, and coronary segment location demonstrated improved incremental prognostic utility beyond traditional RF alone (C-statistics range 0.71-0.73, all P < 0.05; incremental χ2 range 20.7-25.5, all P < 0.001). However, no added prognostic benefit was offered by CCTA findings when added to a base model containing both traditional RF and CACS (C-statistics P > 0.05, for all). Coronary computed tomographic angiography improved prognostication of 6-year all-cause mortality beyond a set of conventional RF alone, although, no further incremental value was offered by CCTA when CCTA findings were added to a model incorporating RF and CACS.

  18. Deep learning analysis of the myocardium in coronary CT angiography for identification of patients with functionally significant coronary artery stenosis.

    PubMed

    Zreik, Majd; Lessmann, Nikolas; van Hamersvelt, Robbert W; Wolterink, Jelmer M; Voskuil, Michiel; Viergever, Max A; Leiner, Tim; Išgum, Ivana

    2018-02-01

    In patients with coronary artery stenoses of intermediate severity, the functional significance needs to be determined. Fractional flow reserve (FFR) measurement, performed during invasive coronary angiography (ICA), is most often used in clinical practice. To reduce the number of ICA procedures, we present a method for automatic identification of patients with functionally significant coronary artery stenoses, employing deep learning analysis of the left ventricle (LV) myocardium in rest coronary CT angiography (CCTA). The study includes consecutively acquired CCTA scans of 166 patients who underwent invasive FFR measurements. To identify patients with a functionally significant coronary artery stenosis, analysis is performed in several stages. First, the LV myocardium is segmented using a multiscale convolutional neural network (CNN). To characterize the segmented LV myocardium, it is subsequently encoded using unsupervised convolutional autoencoder (CAE). As ischemic changes are expected to appear locally, the LV myocardium is divided into a number of spatially connected clusters, and statistics of the encodings are computed as features. Thereafter, patients are classified according to the presence of functionally significant stenosis using an SVM classifier based on the extracted features. Quantitative evaluation of LV myocardium segmentation in 20 images resulted in an average Dice coefficient of 0.91 and an average mean absolute distance between the segmented and reference LV boundaries of 0.7 mm. Twenty CCTA images were used to train the LV myocardium encoder. Classification of patients was evaluated in the remaining 126 CCTA scans in 50 10-fold cross-validation experiments and resulted in an area under the receiver operating characteristic curve of 0.74 ± 0.02. At sensitivity levels 0.60, 0.70 and 0.80, the corresponding specificity was 0.77, 0.71 and 0.59, respectively. The results demonstrate that automatic analysis of the LV myocardium in a single

  19. On angiography with a Thomson laser-electron X-ray generator

    NASA Astrophysics Data System (ADS)

    Vinogradov, A. V.; Vinogradov, S. L.; D'yachkov, N. V.; Polunina, A. V.; Postnov, A. A.

    2017-02-01

    We consider a possibility of application of laser-electron X-ray generators for diagnosing the vessel status of internal organs. It is shown that modern lasers and linear accelerators can be used for the development of angiographic instruments of a new type with an increased spatial and temporal resolution while maintaining or reducing the radiation load on the patient and medical staff. Such improvements in diagnostic and ambient factors cannot be achieved with the use of X-ray tubes. All particular estimates and calculations have been performed for a contrast agent based on iodine compounds.

  20. Lack of Serum Creatinine Decrease After Coronary Angiography Despite Prophylactic Hydration After Routine Coronary Angiography/Angioplasty in Stable Angina Patients--Pilot Study.

    PubMed

    Burchardt, Pawel; Rzezniczak, Janusz; Synowiec, Tomasz; Angerer, Dariusz; Palasz, Anna; Zurawski, Jakub

    2016-01-01

    To prevent contrast induced renal dysfunction a periprocedural prophylactic hydration is applied. Due to dilution it should cause a drop in serum creatinine concentration (SCR). Surprisingly, no reduction in SCR after contrast admission is found in up to 25% of patients as early as 12-18 hours after coronary angiography/angioplasty. This study aims to find a clinical explanation as well as predict circumstances for this phenomenon. Retrospective clinical and laboratory data was used from 341 patients who underwent elective coronary angiography/angioplasty, received a prophylactic hydration, and had serum creatinine concentration measured prior to, and 12-18 hours after invasive procedure with iodine contrast administration. To exclude an improper hydration due to no creatinine decrease, the number of red blood cells was analysed as well as hemoglobin and hematocrit in blood donations collected during the study time points. The resulting lack of serum creatinine reduction could be explained by dehydration (measured by increase in number of RBC, HGB and HCT) only in 13.5% , 10.8%, and 20% of cases, respectively. Any form of abnormal glucose metabolism combined with either baseline serum creatinine concentration <0.87 mg/dL or creatinine clearance >86.77 mL/min, or GFR by CKD EPI >80.08 mL/min/1.73 m2, or GFR by MDRD >74.48 mL/min/1.73 m2 were the predictors for no creatinine decrease at outcome. Additionally, it was demonstrated that the lack of creatinine decrease was more often observed among those patients whose initial renal function was better than in the subjects with reduction of SCR. This observation requires further prospective investigation on extended group of patients. © 2016 The Author(s) Published by S. Karger AG, Basel.

  1. Coronary flow reserve/diastolic function relationship in angina-suffering patients with normal coronary angiography.

    PubMed

    Anchisi, Chiara; Marti, Giuliano; Bellacosa, Ilaria; Mary, David; Vacca, Giovanni; Marino, Paolo; Grossini, Elena

    2017-05-01

    Coronary blood flow and diastolic function are well known to interfere with each other through mechanical and metabolic mechanisms. We aimed to assess the relationship between coronary flow reserve (CFR) and diastolic dysfunction in patients suffering from angina but with normal coronary angiography. In 16 patients with chest pain and angiographically normal coronary arteries, CFR was measured using transthoracic echo-Doppler by inducing hyperemia through dipyridamole infusion. Diastolic function (E/A, deceleration time, isovolumetric relaxation time [IVRT], propagation velocity [Vp]) and left ventricular mass were evaluated by means of two-dimensional transthoracic echocardiography. The patients were initially divided into two groups on the grounds of CFR only (ACFR: altered CFR, n = 9; NACFR: unaltered CFR, n = 7). Thereafter they were divided into four groups on the grounds of CFR and diastolic function (NN: normal; AA: altered CFR/diastole; AN: altered CFR/normal diastole; NA: normal CFR/altered diastole). Most of the subjects were scheduled in AA (n = 8) or NA (n = 5) groups, which were taken into consideration for further analysis. Patients were not different regarding various risk factors. ACFR and AA patients were older with normal body weight in comparison with NACFR and NA patients (P < 0.05). In the AA group, CFR and diastolic variables were found to be related to each other. Diastolic dysfunction and reduced CFR were correlated in patients with concomitant alterations of those variables only. Because most risk factors were shared with patients with altered diastolic properties only, our findings could represent a direct relationship between altered CFR and diastole.

  2. Enhanced coronary calcium visualization and detection from dual energy chest x-rays with sliding organ registration.

    PubMed

    Wen, Di; Nye, Katelyn; Zhou, Bo; Gilkeson, Robert C; Gupta, Amit; Ranim, Shiraz; Couturier, Spencer; Wilson, David L

    2018-03-01

    We have developed a technique to image coronary calcium, an excellent biomarker for atherosclerotic disease, using low cost, low radiation dual energy (DE) chest radiography, with potential for widespread screening from an already ordered exam. Our dual energy coronary calcium (DECC) processing method included automatic heart silhouette segmentation, sliding organ registration and scatter removal to create a bone-image-like, coronary calcium image with significant reduction in motion artifacts and improved calcium conspicuity compared to standard, clinically available DE processing. Experiments with a physical dynamic cardiac phantom showed that DECC processing reduced 73% of misregistration error caused by cardiac motion over a wide range of heart rates and x-ray radiation exposures. Using the functional measurement test (FMT), we determined significant image quality improvement in clinical images with DECC processing (p < 0.0001), where DECC images were chosen best in 94% of human readings. Comparing DECC images to registered and projected CT calcium images, we found good correspondence between the size and location of calcification signals. In a very preliminary coronary calcium ROC study, we used CT Agatston calcium score >50 as the gold standard for an actual positive test result. AUC performance was significantly improved from 0.73 ± 0.14 with standard DE to 0.87 ± 0.10 with DECC (p = 0.0095) for this limited set of surgical patient data biased towards heavy calcifications. The proposed DECC processing shows good potential for coronary calcium detection in DE chest radiography, giving impetus for a larger clinical evaluation. Copyright © 2018. Published by Elsevier Ltd.

  3. Cost-effectiveness of follow-up of pulmonary nodules incidentally detected on cardiac computed tomographic angiography in patients with suspected coronary artery disease.

    PubMed

    Goehler, Alexander; McMahon, Pamela M; Lumish, Heidi S; Wu, Carol C; Munshi, Vidit; Gilmore, Michael; Chung, Jonathan H; Ghoshhajra, Brian B; Mark, Daniel; Truong, Quynh A; Gazelle, G Scott; Hoffmann, Udo

    2014-08-19

    Pulmonary nodules (PNs) are often detected incidentally during coronary computed tomographic (CT) angiography, which is increasingly being used to evaluate patients with chest pain symptoms. However, the efficiency of following up on incidentally detected PN is unknown. We determined demographic and clinical characteristics of stable symptomatic patients referred for coronary CT angiography in whom incidentally detected PNs warranted follow-up. A validated lung cancer simulation model was populated with data from these patients, and clinical and economic consequences of follow-up per Fleischner guidelines versus no follow-up were simulated. Of the 3665 patients referred for coronary CT angiography, 591 (16%) had PNs requiring follow-up. The mean age of patients with PNs was 59±10 years; 66% were male; 67% had ever smoked; and 21% had obstructive coronary artery disease. The projected overall lung cancer incidence was 5.8% in these patients, but the majority died of coronary artery disease (38%) and other causes (57%). Follow-up of PNs was associated with a 4.6% relative reduction in cumulative lung cancer mortality (absolute mortality: follow-up, 4.33% versus non-follow-up, 4.54%), more downstream testing (follow-up, 2.34 CTs per patient versus non-follow-up, 1.01 CTs per patient), and an average increase in quality-adjusted life of 7 days. Costs per quality-adjusted life-year gained were $154 700 to follow up the entire cohort and $129 800 per quality-adjusted life-year when only smokers were included. Follow-up of PNs incidentally detected in patients undergoing coronary CT angiography for chest pain evaluation is associated with a small reduction in lung cancer mortality. However, significant downstream testing contributes to limited efficiency, as demonstrated by a high cost per quality-adjusted life-year, especially in nonsmokers. © 2014 American Heart Association, Inc.

  4. Free and open-source software application for the evaluation of coronary computed tomography angiography images.

    PubMed

    Hadlich, Marcelo Souza; Oliveira, Gláucia Maria Moraes; Feijóo, Raúl A; Azevedo, Clerio F; Tura, Bernardo Rangel; Ziemer, Paulo Gustavo Portela; Blanco, Pablo Javier; Pina, Gustavo; Meira, Márcio; Souza e Silva, Nelson Albuquerque de

    2012-10-01

    The standardization of images used in Medicine in 1993 was performed using the DICOM (Digital Imaging and Communications in Medicine) standard. Several tests use this standard and it is increasingly necessary to design software applications capable of handling this type of image; however, these software applications are not usually free and open-source, and this fact hinders their adjustment to most diverse interests. To develop and validate a free and open-source software application capable of handling DICOM coronary computed tomography angiography images. We developed and tested the ImageLab software in the evaluation of 100 tests randomly selected from a database. We carried out 600 tests divided between two observers using ImageLab and another software sold with Philips Brilliance computed tomography appliances in the evaluation of coronary lesions and plaques around the left main coronary artery (LMCA) and the anterior descending artery (ADA). To evaluate intraobserver, interobserver and intersoftware agreements, we used simple and kappa statistics agreements. The agreements observed between software applications were generally classified as substantial or almost perfect in most comparisons. The ImageLab software agreed with the Philips software in the evaluation of coronary computed tomography angiography tests, especially in patients without lesions, with lesions < 50% in the LMCA and < 70% in the ADA. The agreement for lesions > 70% in the ADA was lower, but this is also observed when the anatomical reference standard is used.

  5. Effect of sleep-inducing music on sleep in persons with percutaneous transluminal coronary angiography in the cardiac care unit.

    PubMed

    Ryu, Min-Jung; Park, Jeong Sook; Park, Heeok

    2012-03-01

    The study compared the effect of earplug-delivered sleep-inducing music on sleep in persons with percutaneous transluminal coronary angiography in the cardiac care unit. Diverse types of music have been claimed to improve sleeping elsewhere, but relatively little is known in South Korea. Most studies investigating the effect of sleep-inducing music on sleep have involved persons with insomnia, even though many persons with cardiovascular disease in the intensive care unit suffer from sleeping problems. There is a need to investigate the effect of sleep-inducing music on sleep disorders in persons with percutaneous transluminal coronary angiography in the cardiac care unit. An experimental research design was used. Data collection was conducted in the cardiac care unit of K University Hospital in D city, from 3 September-4 October 2010. Fifty-eight subjects participated and were randomly assigned to the experimental group (earplug-delivered sleep-inducing music for 52 min beginning at 10:00 pm, while wearing an eyeshield, n = 29) and the control group (no music, but earplugs and eyeshield worn, n = 29). The quantity and quality of sleep were measured using questionnaires at 7 am the next morning for each group. Participants in the experimental group reported that the sleeping quantity and quality were significantly higher than control group (t = 3·181, p = 0·002, t = 5·269, p < 0·001, respectively). Sleep-inducing music significantly improved sleep in patients with percutaneous transluminal coronary angiography at a cardiac care unit. Offering earplugs and playing sleep-inducing music may be a meaningful and easily enacted nursing intervention to improve sleep for intensive care unit patients. Nurses working at cardiac care unit can use music to improve sleeping in clients with percutaneous transluminal coronary angiography. © 2011 Blackwell Publishing Ltd.

  6. Management and decision-making process leading to coronary angiography and revascularization in octogenarians with coronary artery disease: Insights from a large single-center registry.

    PubMed

    Martin, Anne-Céline; Dumas, Florence; Spaulding, Christian; Manzo-Silberman, Stéphane

    2015-05-01

    Cardiovascular diseases remain the most common cause of death in older adults. Guidelines state that advanced age alone should not limit the use of invasive therapy. However, coronary angiograms and subsequent revascularization are often not carried out in octogenarians. The benefit/risk balance of an invasive strategy and the decision-making process are not clearly defined. The aim of the present study was to assess the decision-making process, and the in-hospital and long-term mortality based on the clinical presentation, the diagnostic approach (coronary angiogram or conservative) and the therapeutic management (revascularization or not). The present study was a single-center retrospective analysis. A total of 522 patients aged ≥80 years, with a diagnosis of coronary disease were included from 2003 to 2009. The mean age was 82 ± 2.6 years. A total of 195 of 522 (37%) presented with a ST segment elevation myocardial infarction (STEMI). A coronary angiogram was carried out in 316 patients (60.5%) and 71% were treated by percutaneous coronary revascularization. A total of 39.5% were considered ineligible for a coronary angiogram due to cardiological reasons or comorbidities. Excluding cardiogenic shock, overall in-hospital mortality was 4.9%. Clinical presentation strongly influenced both in-hospital and 6-month mortality rates (cardiogenic shock 20% and 28.7%, stable angina 1% and 4.1%, respectively, P < 0.001). Long-term mortality was reduced in the coronary angiography arm compared with the conservative group (14.3% vs 20.9%, P = 0.04) whether or not revascularization was carried out. In the present study, in octogenarians, long-term mortality was lower in the group of patients who underwent a coronary angiogram, regardless of revascularization. The selection process for coronary angiography and angioplasty was mostly influenced by the existence of age-associated comorbidities. Risk prediction models are required to reduce age-dependent biases.

  7. X-ray detectors in medical imaging

    NASA Astrophysics Data System (ADS)

    Spahn, Martin

    2013-12-01

    Healthcare systems are subject to continuous adaptation, following trends such as the change of demographic structures, the rise of life-style related and chronic diseases, and the need for efficient and outcome-oriented procedures. This also influences the design of new imaging systems as well as their components. The applications of X-ray imaging in the medical field are manifold and have led to dedicated modalities supporting specific imaging requirements, for example in computed tomography (CT), radiography, angiography, surgery or mammography, delivering projection or volumetric imaging data. Depending on the clinical needs, some X-ray systems enable diagnostic imaging while others support interventional procedures. X-ray detector design requirements for the different medical applications can vary strongly with respect to size and shape, spatial resolution, frame rates and X-ray flux, among others. Today, integrating X-ray detectors are in common use. They are predominantly based on scintillators (e.g. CsI or Gd2O2S) and arrays of photodiodes made from crystalline silicon (Si) or amorphous silicon (a-Si) or they employ semiconductors (e.g. Se) with active a-Si readout matrices. Ongoing and future developments of X-ray detectors will include optimization of current state-of-the-art integrating detectors in terms of performance and cost, will enable the usage of large size CMOS-based detectors, and may facilitate photon counting techniques with the potential to further enhance performance characteristics and foster the prospect of new clinical applications.

  8. Regional rates of myocardial fatty acid metabolism: comparison with coronary angiography and ventriculography.

    PubMed

    Schad, N; Wagner, R K; Hallermeier, J; Daus, H J; Vattimo, A; Bertelli, P

    1990-01-01

    In 50 patients, 1 mCi 123I phenylpentadecanoic acid (IPPA) was injected at peak ergometric stress and 1500 frames were acquired (1 frame/s) with a high count rate gamma camera. Parametric images of rates of decrease and increase for different time intervals after stress were compared with coronary angiography and LV ventriculography, separately evaluating the 3 main coronary territories: 18/150 territories supplied by normal coronaries presented rather homogeneous regional clearing rates, whereas a gradual decrease in clearing rates towards the end of the territory (frequently with peripheral defects) was seen in all 87/150 territories with significant coronary narrowing. In local correspondence to clearing defects, initial IPPA accumulations could be observed with later onset of clearing between 10 and 25 min. 44/150 territories presented abnormal clearing rates, mostly with a patchy pattern, with normal coronary anatomy, but all except one had LV dysfunction and a clinical diagnosis of cardiomyopathy, diabetes mellitus or hypertensive disease. Twenty four of the 41 patients with CAD had, in correspondence to a prior myocardial infarction, minimum or missing metabolic activity frequently in circumscribed zones, partly separated by bridges of still viable tissue with preserved but reduced clearing rates.

  9. Ethnic differences in invasive management of coronary disease: prospective cohort study of patients undergoing angiography

    PubMed Central

    Feder, Gene; Crook, Angela M; Magee, Patrick; Banerjee, Shrilla; Timmis, Adam D; Hemingway, Harry

    2002-01-01

    Objectives To compare rates of revascularisation in south Asian and white patients undergoing coronary angiography in relation to the appropriateness of revascularisation and clinical outcome. Design Prospective cohort study of patients with two and a half years' follow up; appropriateness of revascularisation rated by nine experts with no knowledge of ethnicity of patient. Setting Tertiary cardiac centre in London with referral from five contiguous health authorities. Participants Consecutive patients (502 south Asian, 2974 white) undergoing coronary angiography in the appropriateness of coronary revascularisation study (ACRE). Main outcome measures Coronary revascularisation, non-fatal myocardial infarction, mortality. Results There was no difference between south Asian and white patients in the proportions deemed appropriate for revascularisation (72% (361) v 68% (2022)) or in the proportions for whom the physician's intended management was revascularisation (39% (196) v 41% (1218)). Among patients appropriate for revascularisation, age adjusted rates of coronary angioplasty (hazard ratio 0.69, 95% confidence interval 0.47 to 1.00, P=0.058) and coronary artery bypass grafting (0.74, 0.58 to 0.91, P=0.007) were lower in south Asian than in white patients. These differences were smaller but still present after adjustment for socioeconomic status and after restriction of analysis to those patients for whom the intended management was revascularisation. There were no differences in mortality and non-fatal myocardial infarction between south Asian and white patients (1.07, 0.78 to 1.47). Conclusion Among patients deemed appropriate for coronary artery bypass grafting, south Asian patients are less likely than white patients to receive it. This difference is not explained by physician bias. What is already known on this topicUS studies have shown inequity in use of cardiac revascularisation procedures between white patients and African-AmericansStudies in England

  10. Hafnium-Based Contrast Agents for X-ray Computed Tomography.

    PubMed

    Berger, Markus; Bauser, Marcus; Frenzel, Thomas; Hilger, Christoph Stephan; Jost, Gregor; Lauria, Silvia; Morgenstern, Bernd; Neis, Christian; Pietsch, Hubertus; Sülzle, Detlev; Hegetschweiler, Kaspar

    2017-05-15

    Heavy-metal-based contrast agents (CAs) offer enhanced X-ray absorption for X-ray computed tomography (CT) compared to the currently used iodinated CAs. We report the discovery of new lanthanide and hafnium azainositol complexes and their optimization with respect to high water solubility and stability. Our efforts culminated in the synthesis of BAY-576, an uncharged hafnium complex with 3:2 stoichiometry and broken complex symmetry. The superior properties of this asymmetrically substituted hafnium CA were demonstrated by a CT angiography study in rabbits that revealed excellent signal contrast enhancement.

  11. Influence of Microcirculatory Dysfunction on Angiography-Based Functional Assessment of Coronary Stenoses.

    PubMed

    Mejía-Rentería, Hernán; Lee, Joo Myung; Lauri, Francesco; van der Hoeven, Nina W; de Waard, Guus A; Macaya, Fernando; Pérez-Vizcayno, María José; Gonzalo, Nieves; Jiménez-Quevedo, Pilar; Nombela-Franco, Luis; Salinas, Pablo; Núñez-Gil, Iván; Del Trigo, María; Goto, Sonoka; Lee, Hyun Jong; Liontou, Catherine; Fernández-Ortiz, Antonio; Macaya, Carlos; van Royen, Niels; Koo, Bon-Kwon; Escaned, Javier

    2018-04-23

    The authors sought to evaluate the influence of coronary microcirculatory dysfunction (CMD) on the diagnostic performance of the quantitative flow ratio (QFR). Functional angiographic assessment of coronary stenoses based on fluid dynamics, such as QFR, constitutes an attractive alternative to fractional flow reserve (FFR). However, it is unknown whether CMD affects the reliability of angiography-based functional indices. FFR and the index of microcirculatory resistance (IMR) were measured in 300 vessels (248 patients) as part of a multicenter international registry. QFR was calculated at a blinded core laboratory. Vessels were classified into 2 groups according to microcirculatory status: low IMR (<23 U), and high IMR (≥23 U, CMD). The impact of CMD on the diagnostic performance of QFR, as well as on incremental value of QFR over quantitative angiography, was assessed using FFR as reference. Percent diameter stenosis (%DS) and FFR were similar in low- and high-IMR groups (%DS 51 ± 12% vs. 53 ± 11%; p = 0.16; FFR 0.80 ± 0.11 vs. 0.81 ± 0.11; p = 0.23, respectively). In the overall cohort, classification agreement (CA) between QFR and FFR and diagnostic efficiency of QFR (area under the receiver-operating characteristics curve [AUC]) were high (CA: 88%; AUC: 0.93 [95% confidence interval (CI): 0.90 to 0.96]). However, when assessed according to microcirculatory status, a significantly lower CA and AUC of QFR were found in the high-IMR group as compared with the low-IMR group (CA: 76% vs. 92%; p < 0.001; AUC: 0.88 [95% CI: 0.79 to 0.94] vs. 0.96 [95% CI: 0.92 to 0.98]; p < 0.05). Compared with angiographic assessment, QFR increased by 0.20 (p < 0.001) and by 0.16 (p < 0.001) the AUC of %DS in low- and high-IMR groups, respectively. Independent predictors of misclassification between QFR and FFR were high IMR and acute coronary syndrome. CMD decreases the diagnostic performance of QFR. However, even in the presence of CMD, QFR remains superior to

  12. Safety of an i.v. β-adrenergic blockade protocol for heart rate optimization before coronary CT angiography.

    PubMed

    Kassamali, Rahil H; Kim, Daniel H; Patel, Hiten; Raichura, Nitin; Hoey, Edward T D; Hodson, James; Hussain, Shahid

    2014-10-01

    The purpose of this study was to assess the safety of heart rate optimization by use of β-adrenergic blockade solely by the i.v. route before coronary CT angiography. The records of 679 patients undergoing CT coronary angiography after receiving i.v. β-adrenergic blockade were retrospectively analyzed. Health screening was completed before scanning, and heart rate was optimized by administration of i.v. metoprolol titrated to a maximum of 70 mg to achieve a heart rate less than 65 beats/min. The median i.v. dose was 20 mg (range, 5-70 mg). The 679 patients analyzed had a total of 10 complications (1.47%). Major complications, defined as not resolving with observation and analgesia alone, occurred in only three patients (0.44%). These complications included a second-degree atrioventricular block. A total of 299 patients (44.0%) needed more than 20 mg of i.v. metoprolol to achieve target heart rate. Only three patients needed the maximum i.v. dose of 70 mg metoprolol. Target heart rate was reached successfully in 666 patients (98.1%) with doses of less than 70 mg. This study did not show a statistically significant association between increasing complication frequency and increasing dose. This study showed that high doses of i.v. metoprolol can be used effectively and with a low rate of major complications to control heart rate before coronary CT angiography in correctly screened patients.

  13. Four-dimensional respiratory motion-resolved whole heart coronary MR angiography.

    PubMed

    Piccini, Davide; Feng, Li; Bonanno, Gabriele; Coppo, Simone; Yerly, Jérôme; Lim, Ruth P; Schwitter, Juerg; Sodickson, Daniel K; Otazo, Ricardo; Stuber, Matthias

    2017-04-01

    Free-breathing whole-heart coronary MR angiography (MRA) commonly uses navigators to gate respiratory motion, resulting in lengthy and unpredictable acquisition times. Conversely, self-navigation has 100% scan efficiency, but requires motion correction over a broad range of respiratory displacements, which may introduce image artifacts. We propose replacing navigators and self-navigation with a respiratory motion-resolved reconstruction approach. Using a respiratory signal extracted directly from the imaging data, individual signal-readouts are binned according to their respiratory states. The resultant series of undersampled images are reconstructed using an extradimensional golden-angle radial sparse parallel imaging (XD-GRASP) algorithm, which exploits sparsity along the respiratory dimension. Whole-heart coronary MRA was performed in 11 volunteers and four patients with the proposed methodology. Image quality was compared with that obtained with one-dimensional respiratory self-navigation. Respiratory-resolved reconstruction effectively suppressed respiratory motion artifacts. The quality score for XD-GRASP reconstructions was greater than or equal to self-navigation in 80/88 coronary segments, reaching diagnostic quality in 61/88 segments versus 41/88. Coronary sharpness and length were always superior for the respiratory-resolved datasets, reaching statistical significance (P < 0.05) in most cases. XD-GRASP represents an attractive alternative for handling respiratory motion in free-breathing whole heart MRI and provides an effective alternative to self-navigation. Magn Reson Med 77:1473-1484, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  14. Cost analysis of non-invasive fractional flow reserve derived from coronary computed tomographic angiography in Japan.

    PubMed

    Kimura, Takeshi; Shiomi, Hiroki; Kuribayashi, Sachio; Isshiki, Takaaki; Kanazawa, Susumu; Ito, Hiroshi; Ikeda, Shunya; Forrest, Ben; Zarins, Christopher K; Hlatky, Mark A; Norgaard, Bjarne L

    2015-01-01

    Percutaneous coronary intervention (PCI) based on fractional flow reserve (FFRcath) measurement during invasive coronary angiography (CAG) results in improved patient outcome and reduced healthcare costs. FFR can now be computed non-invasively from standard coronary CT angiography (cCTA) scans (FFRCT). The purpose of this study is to determine the potential impact of non-invasive FFRCT on costs and clinical outcomes of patients with suspected coronary artery disease in Japan. Clinical data from 254 patients in the HeartFlowNXT trial, costs of goods and services in Japan, and clinical outcome data from the literature were used to estimate the costs and outcomes of 4 clinical pathways: (1) CAG-visual guided PCI, (2) CAG-FFRcath guided PCI, (3) cCTA followed by CAG-visual guided PCI, (4) cCTA-FFRCT guided PCI. The CAG-visual strategy demonstrated the highest projected cost ($10,360) and highest projected 1-year death/myocardial infarction rate (2.4 %). An assumed price for FFRCT of US $2,000 produced equivalent clinical outcomes (death/MI rate: 1.9 %) and healthcare costs ($7,222) for the cCTA-FFRCT strategy and the CAG-FFRcath guided PCI strategy. Use of the cCTA-FFRCT strategy to select patients for PCI would result in 32 % lower costs and 19 % fewer cardiac events at 1 year compared to the most commonly used CAG-visual strategy. Use of cCTA-FFRCT to select patients for CAG and PCI may reduce costs and improve clinical outcome in patients with suspected coronary artery disease in Japan.

  15. Coronary artery segmentation in X-ray angiograms using gabor filters and differential evolution.

    PubMed

    Cervantes-Sanchez, Fernando; Cruz-Aceves, Ivan; Hernandez-Aguirre, Arturo; Solorio-Meza, Sergio; Cordova-Fraga, Teodoro; Aviña-Cervantes, Juan Gabriel

    2018-08-01

    Segmentation of coronary arteries in X-ray angiograms represents an essential task for computer-aided diagnosis, since it can help cardiologists in diagnosing and monitoring vascular abnormalities. Due to the main disadvantages of the X-ray angiograms are the nonuniform illumination, and the weak contrast between blood vessels and image background, different vessel enhancement methods have been introduced. In this paper, a novel method for blood vessel enhancement based on Gabor filters tuned using the optimization strategy of Differential evolution (DE) is proposed. Because the Gabor filters are governed by three different parameters, the optimal selection of those parameters is highly desirable in order to maximize the vessel detection rate while reducing the computational cost of the training stage. To obtain the optimal set of parameters for the Gabor filters, the area (Az) under the receiver operating characteristics curve is used as objective function. In the experimental results, the proposed method achieves an A z =0.9388 in a training set of 40 images, and for a test set of 40 images it obtains the highest performance with an A z =0.9538 compared with six state-of-the-art vessel detection methods. Finally, the proposed method achieves an accuracy of 0.9423 for vessel segmentation using the test set. In addition, the experimental results have also shown that the proposed method can be highly suitable for clinical decision support in terms of computational time and vessel segmentation performance. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Coronary Events and Anatomy After Arterial Switch Operation for Transposition of the Great Arteries: Detection by 16-Row Multislice Computed Tomography Angiography in Pediatric Patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oztunc, Funda, E-mail: foztunc@yahoo.com; Baris, Safa, E-mail: safabaris@hotmail.co; Adaletli, Ibrahim, E-mail: iadaletli@yahoo.com

    2009-03-15

    The purpose of this study was to evaluate the feasibility of multislice computed tomographic (MSCT) angiography as a noninvasive method for detecting ostial, proximal, and middle segment coronary stenosis or occlusion and anatomy in patients with transposition of the great arteries who had undergone arterial switch operation (ASO). Sixteen-detector-row MSCT angiography was performed in 16 patients treated with ASO for transposition of the great arteries. The median age was 10.3 years (range, 6.2-16.3 years). Sixteen-detector-row MSCT angiography was performed in 16 patients who had undergone ASO. CT imaging was performed in the craniocaudal direction from 2 cm above the carinamore » up to the heart basis. Noninvasive assessment of coronary artery stenosis and anatomy were investigated by MSCT angiography. Two patients were excluded from the study because of artifacts. Of 14 evaluated patients, 1 patient had ostial stenosis (7.1%). A coronary artery anatomy variant was present in six patients: left main artery (LMA) and right coronary artery (RCA) originating from the right sinus as a single orifice (n = 2); left circumflex artery (LCX) originating from the RCA (n = 1); LMA and RCA, after branching to the LCX, originating separately from the right sinus (n = 1); and LMA (n = 1) and left anterior descending artery (LADA; n = 1) originating directly from the right sinus. Intramural bridging in the LAD (n = 2) was detected. Five patients were normal. In conclusion, MSCT angiography, as a noninvasive, feasible technique for assessing coronary stenosis or occlusion and anatomy, can be used in the follow-up of patients who have undergone ASO.« less

  17. Diagnostic performance of 64-slice multidetector coronary computed tomographic angiography in women.

    PubMed

    Jug, Borut; Gupta, Mohit; Papazian, Jenny; Li, Dong; Tsang, Janet; Bhatia, Harpreet; Karlsberg, Ronald; Budoff, Matthew

    2012-12-01

    Diagnostic approach to chest pain in women is challenging, but still under-investigated. The purpose of this study was to assess the diagnostic performance of 64-slice multidetector coronary computed tomographic angiography (CCTA) in women with chest pain. We included 606 patients--255 women and 351 men (mean age 61 ± 12 years for both)--who had been referred for a CCTA and an invasive coronary angiography (diagnostic standard) because of chest pain, either as part of clinical work-up in two urban medical centers or as part of the multicenter ACCURACY trial. On a patient-based model, the sensitivity, specificity, and positive predictive value (PPV) and negative predictive value to detect ≥50% and ≥70% stenosis were 98%, 84%, 87%, and 97% and 96%, 83%, 77%, and 97%, respectively, for women and 97%, 83%, 89%, and 95% and 94%, 91%, 90%, and 94%, respectively, for men. There were no statistically significant differences between men and women in diagnostic performance measures except for the PPV of detecting a ≥70% stenosis (P = .007). In women with chest pain, 64-slice multidetector CCTA is at least as sensitive and specific as in men. Our findings suggest that CCTA is a promising diagnostic tool for timely detection and/or exclusion of CAD in symptomatic intermediate-risk female populations.

  18. Diagnostic Accuracy of CT Coronary Angiography According to Pretest Probability of Coronary Artery Disease and Severity of Coronary Arterial Calcification: The CorE-64 International, Multicenter Study

    PubMed Central

    Arbab-Zadeh, Armin; Miller, Julie M; Rochitte, Carlos E; Dewey, Marc; Niinuma, Hiroyuki; Gottlieb, Ilan; Paul, Narinder; Clouse, Melvin E.; Shapiro, Edward P.; Hoe, John; Lardo, Albert C.; Bush, David E.; de Roos, Albert; Cox, Christopher; Brinker, Jeffrey; Lima, Joăo A. C.

    2012-01-01

    Objectives Assess the impact of patient population characteristics on accuracy by CT angiography (CTA) to detect obstructive coronary artery disease (CAD). Background The ability of CTA to exclude obstructive CAD in patients of different pretest probabilities and in presence of coronary calcification remains uncertain. Methods For the CorE-64 study 371 patients underwent CTA and cardiac catheterization for the detection of obstructive CAD defined as 50% or greater luminal stenosis by quantitative coronary angiography (QCA). This analysis includes 80 initially excluded patients with a calcium score ≥ 600. Area under the receiver-operating-characteristics curve (AUC) was used to evaluate CTA diagnostic accuracy compared to QCA in patients according to calcium score and pretest probability of CAD. Results Analysis of patient-based quantitative CTA accuracy revealed an AUC of 0.93 (95% confidence interval [CI] 0.90-0.95). AUC remained 0.93 (0.90-0.96) after excluding patients with known CAD but decreased to 0.81 (0.71-0.89) in patients with calcium score ≥ 600 (p=0.077). While AUC were similar (0.93, 0.92, and 0.93, respectively) for patients with intermediate, high pretest probability for CAD, and known CAD, negative predictive values were different: 0.90, 0.83, and 0.50, respectively. Negative predictive values decreased from 0.93 to 0.75 for patients with calcium score < or ≥ 100, respectively (p= 0.053). Conclusions Both pretest probability for CAD and coronary calcium scoring should be considered before using CTA for excluding obstructive CAD. CTA is less effective for this purpose in patients with calcium score ≥ 600 and in patients with a high pretest probability for obstructive CAD. PMID:22261160

  19. Pre-Interventional Kynurenine Predicts Medium-Term Outcome after Contrast Media Exposure Due to Coronary Angiography.

    PubMed

    Reichetzeder, Christoph; Heunisch, Fabian; Einem, Gina von; Tsuprykov, Oleg; Kellner, Karl-Heinz; Dschietzig, Thomas; Kretschmer, Axel; Hocher, Berthold

    2017-01-01

    Contrast induced acute kidney injury (CI-AKI) remains a serious complication of contrast media enhanced procedures like coronary angiography. There is still a lack of established biomarkers that help to identify patients at high risk for short and long-term complications. The aim of the current study was to evaluate plasma kynurenine as a predictive biomarker for CI-AKI and long-term complications, measured by the combined endpoint "major adverse kidney events" (MAKE) up to 120 days after CM application. In this prospective cohort study 245 patients undergoing coronary angiography were analyzed. Blood samples were obtained at baseline, 24h and 48h after contrast media (CM) application to diagnose CI-AKI. Patients were followed for 120 days for adverse clinical events including death, the need for dialysis, and a doubling of plasma creatinine. Occurrence of any of these events was summarized in the combined endpoint MAKE. Preinterventional plasma kynurenine was not associated with CI-AKI. Patients who later developed MAKE displayed significantly increased preinterventional plasma kynurenine levels (p<0.0001). ROC analysis revealed that preinterventional kynurenine is highly predictive for MAKE (AUC=0.838; p<0.0001). The optimal cutoff was found at ≥3.5 µmol/L Using this cutoff, the Kaplan-Meier estimator demonstrated that concentrations of plasma kynurenine ≥3.5 µmol/L were significantly associated with a higher prevalence of MAKE until follow up (p<0.0001). This association remained significant in multivariate Cox regression models adjusted for relevant factors of long-term renal outcome. Preinterventional plasma kynurenine might serve as a highly predictive biomarker for MAKE up to 120 days after coronary angiography. © 2017 The Author(s). Published by S. Karger AG, Basel.

  20. Dual-Axis Rotational Angiography is Safe and Feasible to Detect Coronary Allograft Vasculopathy in Pediatric Heart Transplant Patients: A Single-Center Experience.

    PubMed

    Rios, Rodrigo; Loomba, Rohit S; Foerster, Susan R; Pelech, Andrew N; Gudausky, Todd M

    2016-04-01

    Coronary allograft vasculopathy (CAV) is the leading cause of graft failure in pediatric heart transplant recipients, also adding to mortality in this patient population. Coronary angiography is routinely performed to screen for CAV, with conventional single-plane or bi-plane angiography being utilized. Dual-axis rotational coronary angiography (RA) has been described, mostly in the adult population, and may offer reduction in radiation dose and contrast volume. Experience with this in the pediatric population is limited. This study describes a single-institution experience with RA for screening for CAV in pediatric patients. The catheterization database at our institution was used to identify pediatric heart transplant recipients having undergone RA to screen for CAV. Procedural data including radiation dose, fluoroscopy time, contrast volume, and procedure time were collected for each catheterization. The number of instances in which RA was not successful, ECG changes were present, and CAV was detected were also collected for each catheterization. A total of 97 patients underwent 345 catheterizations utilizing RA. Median radiation dose-area product per kilogram was found to be 341.7 (mGy cm(2)/kg), total air kerma was 126.8 (mGy), procedure time was 69 min, fluoroscopy time was 9.9 min, and contrast volume was 13 ml. A total of 17 (2 %) coronary artery injections out of 690 could not be successfully imaged using RA. A total of 14 patients had CAV noted at any point, 10 of whom had progressive CAV. Electrocardiographic changes were documented in a total of 10 (3 %) RA catheterizations. Procedural characteristics did not differ between serial catheterizations. RA is safe and feasible for CAV screening in pediatric heart transplant recipients while offering coronary imaging in multiple planes compared to conventional angiography.

  1. Identification of High-Risk Plaques Destined to Cause Acute Coronary Syndrome Using Coronary Computed Tomographic Angiography and Computational Fluid Dynamics.

    PubMed

    Lee, Joo Myung; Choi, Gilwoo; Koo, Bon-Kwon; Hwang, Doyeon; Park, Jonghanne; Zhang, Jinlong; Kim, Kyung-Jin; Tong, Yaliang; Kim, Hyun Jin; Grady, Leo; Doh, Joon-Hyung; Nam, Chang-Wook; Shin, Eun-Seok; Cho, Young-Seok; Choi, Su-Yeon; Chun, Eun Ju; Choi, Jin-Ho; Nørgaard, Bjarne L; Christiansen, Evald H; Niemen, Koen; Otake, Hiromasa; Penicka, Martin; de Bruyne, Bernard; Kubo, Takashi; Akasaka, Takashi; Narula, Jagat; Douglas, Pamela S; Taylor, Charles A; Kim, Hyo-Soo

    2018-03-14

    We investigated the utility of noninvasive hemodynamic assessment in the identification of high-risk plaques that caused subsequent acute coronary syndrome (ACS). ACS is a critical event that impacts the prognosis of patients with coronary artery disease. However, the role of hemodynamic factors in the development of ACS is not well-known. Seventy-two patients with clearly documented ACS and available coronary computed tomographic angiography (CTA) acquired between 1 month and 2 years before the development of ACS were included. In 66 culprit and 150 nonculprit lesions as a case-control design, the presence of adverse plaque characteristics (APC) was assessed and hemodynamic parameters (fractional flow reserve derived by coronary computed tomographic angiography [FFR CT ], change in FFR CT across the lesion [△FFR CT ], wall shear stress [WSS], and axial plaque stress) were analyzed using computational fluid dynamics. The best cut-off values for FFR CT , △FFR CT , WSS, and axial plaque stress were used to define the presence of adverse hemodynamic characteristics (AHC). The incremental discriminant and reclassification abilities for ACS prediction were compared among 3 models (model 1: percent diameter stenosis [%DS] and lesion length, model 2: model 1 + APC, and model 3: model 2 + AHC). The culprit lesions showed higher %DS (55.5 ± 15.4% vs. 43.1 ± 15.0%; p < 0.001) and higher prevalence of APC (80.3% vs. 42.0%; p < 0.001) than nonculprit lesions. Regarding hemodynamic parameters, culprit lesions showed lower FFR CT and higher △FFR CT , WSS, and axial plaque stress than nonculprit lesions (all p values <0.01). Among the 3 models, model 3, which included hemodynamic parameters, showed the highest c-index, and better discrimination (concordance statistic [c-index] 0.789 vs. 0.747; p = 0.014) and reclassification abilities (category-free net reclassification index 0.287; p = 0.047; relative integrated discrimination improvement 0.368; p < 0.001) than

  2. Noninvasive detection of coronary artery bypass graft patency by intravenous electron beam computed tomographic angiography.

    PubMed

    Yamakami, Shoji; Toyama, Junji; Okamoto, Mitsuhiro; Matsushita, Toyoaki; Murakami, Yoshimasa; Ogata, Masaki; Ito, Shigenori; Fukutomi, Tatsuya; Okayama, Naotsuka; Itoh, Makoto

    2003-11-01

    This study evaluates the usefullness of intravenous electron beam computed tomographic angiography (EBA) for the detection of coronary artery bypass graft patency in 43 patients (33 men and 10 women, mean age, 65 years) who had coronary artery bypass graft surgery. EBA was performed a few days before selective bypass graft angiography (SGA). Forty axial cross-sections of angiographic images of the heart were acquired consecutively by an electrocardiographic trigger signal at 40% of the RR interval, which corresponds to the end-systolic phase. EBA data were reconstructed as a three-dimensional shaded surface display of the heart and bypass grafts. Detectability of the patency of bypass gratis was evaluated, taking selective angiographic images of the bypass grafts as a gold standard. One hundred and nine grafts (96%) out of 114 grafts were subjected to evaluation: 37 grafts were left internal mammary artery grafts (LIMA), 7 were right internal mammary artery grafts (RIMA), 6 were gastroepiploic artery grafts (GEA), 7 were free gastroepiploic artery grafts with venous drainage (free-GEA), 7 were radial artery grafts (RAG), and 45 were saphenous vein gratis (SVG). The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of EBA were 98%, 100%, 100%, 91%, and 98%, respectively. EBA sampled at the end-systolic period was determined to be useful for the detection of coronary artery bypass graft patency and occlusion.

  3. Development of a fluorescent x-ray source for medical imaging

    NASA Astrophysics Data System (ADS)

    Toyofuku, F.; Tokumori, K.; Nishimura, K.; Saito, T.; Takeda, T.; Itai, Y.; Hyodo, K.; Ando, M.; Endo, M.; Naito, H.; Uyama, C.

    1995-02-01

    A fluorescent x-ray source for medical imaging, such as K-edge subtraction angiography and monochromatic x-ray CT, has been developed. Using a 6.5 GeV accumulation ring in Tsukuba, fluorescent x rays, which range from about 30 to 70 keV are generated by irradiating several target materials. Measurements have been made of output intensities and energy spectra for different target angles and extraction angles. The intensities of fluorescent x rays at a 30 mA beam current are on the order of 1-3×106 photons/mm2/s at 30 cm from the local spot where the incident beam is collimated to 1 mm2. A phantom which contains three different contrast media (iodine, barium, gadolinium) was used for the K-edge energy subtraction, and element selective CT images were obtained.

  4. Systemic effects of intracoronary nitroglycerin during coronary angiography in children after heart transplantation.

    PubMed

    Lara, Diego A; Olive, Mary K; George, James F; Brown, Robert N; Carlo, Waldemar F; Colvin, Edward V; Steenwyck, Brad L; Pearce, F Bennett

    2014-02-01

    Coronary spasm during coronary angiography for vasculopathy in children can be prevented by the intracoronary administration of nitroglycerin. We reviewed the anesthesia and catheterization reports and charts for pediatric transplant recipients who underwent angiography from 2005 through 2010. Correlation analysis was used to study the relation of post-injection systolic blood pressure (SBP) to nitroglycerin dose. Forty-one angiographic evaluations were performed on 25 patients (13 male and 12 female). Mean age was 9.9 ± 3.2 years (range, 3.3-16.1 yr). The mean total dose of nitroglycerin was 2.93 ± 1.60 µg/kg (range, 1-8 µg/kg). There was a significant drop between the baseline SBP (mean, 106 ± 21.6 mmHg) and the lowest mean SBP before nitroglycerin administration (78 ± 13.2, P <0.0001, paired t test). There was no significant additional change in SBP (mean after nitroglycerin administration, 80.7 ± 13.1 mmHg; P = 0.2). There was a significant drop in lowest heart rate between baseline (109 ± 16.5 beats/min) and before nitroglycerin administration (89 ± 14.3 beats/min; P <0.0001, paired t test). There was no significant additional change in heart rate (mean heart rate after nitroglycerin, 84 ± 17.7 beats/min; P = 0.09). There were 2 interventions for SBP before nitroglycerin and 2 after nitroglycerin. One child experienced a transient ST-T-segment change during angiography after nitroglycerin. In the highest dose range, the additional decrease in SBP was 7.2 mmHg (P=0.03). Routine intracoronary nitroglycerin administration in this dose range produced no significant changes in SBP or heart rate in children.

  5. Presence and severity of noncalcified coronary plaque on 64-slice computed tomographic coronary angiography in patients with zero and low coronary artery calcium.

    PubMed

    Cheng, Victor Y; Lepor, Norman E; Madyoon, Hooman; Eshaghian, Shervin; Naraghi, Ashkan L; Shah, Prediman K

    2007-05-01

    How well absence of coronary artery calcium (CAC) predicts the absence of noncalcified coronary artery plaque (NCAP) has not been elucidated. We conducted a cross-sectional study of 554 outpatients to quantify NCAP prevalence as a function of CAC score. All patients underwent CAC scoring followed by 64-slice computed tomographic coronary angiography. Patients were categorized as having 0 CAC (416 patients) or low CAC (138 patients; men with CAC scores from 1 to 50 and women with scores from 1 to 10). Prevalence of detectable NCAP was 6.5% in patients with 0 CAC and 65.2% in those with low CAC. Compared with patients with 0 CAC, those with low CAC had markedly increased rates of NCAP occluding <50% of the arterial lumen (56.5% vs 6.0%, p <0.001) and > or =50% of the arterial lumen (8.7% vs 0.5%, p <0.001). In conclusion, in outpatients with a low to intermediate risk presentation and no known coronary artery disease, absence of CAC predicts low prevalence of any NCAP and very low prevalence of significantly occlusive NCAP. Low but detectable CAC scores are significantly less reliable in predicting plaque burden due to their association with high overall NCAP prevalence and nearly a 10% rate of significantly occlusive NCAP.

  6. Medical personnel and patient dosimetry during coronary angiography and intervention

    NASA Astrophysics Data System (ADS)

    Efstathopoulos, Efstathios P.; Makrygiannis, Stamatis S.; Kottou, Sofia; Karvouni, Evangelia; Giazitzoglou, Eleftherios; Korovesis, Socrates; Tzanalaridou, Efthalia; Raptou, Panagiota D.; Katritsis, Demosthenes G.

    2003-09-01

    Percutaneous coronary interventions are associated with increased radiation exposure compared to most radiological examinations. This prospective study aimed at (1) measuring entrance doses for all in-room personnel, (2) performing an assessment of patient effective dose and intracoronary doses, (3) investigating the contribution of each projection to kerma-area product (KAP) and irradiation time, (4) comparing results with established DRL values in this clinical setting and (5) estimating the risk for fatal cancer to patients and operators. Measurements were performed during 40 consecutive procedures of coronary angiography (CA), half of which were followed by ad hoc coronary angioplasty (PTCA). KAP measurements were used for patients and thermoluminescent dosimetry for the in-room personnel. The mean KAP value per procedure for CA was 29 +/- 9 Gy cm2. Thirty four per cent of KAP was due to fluoroscopy, whereas the remainder (66%) was due to digital cine. Accordingly, the mean KAP value per PTCA procedure was 75 +/- 30 Gy cm2, and contribution of fluoroscopy is 57%. Effective dose per year was estimated to be 0.04-0.05 mSv y-1 for the primary operator, and 0.03-0.04 mSv y-1 for those assisting. Corresponding measurements for radiographer and nurse were below detectable level, implying minimal radiation hazards for them. Regarding radiation exposure, coronary intervention is considered a quite safe procedure for both patients and personnel in laboratories with modern equipment and experienced operators as long as standard safety precautions are considered. Exposure optimization though should be constantly sought through continuous review of procedures.

  7. Challenges of coronary angiography and intervention in patients previously treated by TAVI.

    PubMed

    Blumenstein, Johannes; Kim, Won-Keun; Liebetrau, Christoph; Gaede, Luise; Kempfert, Joerg; Walther, Thomas; Hamm, Christian; Möllmann, Helge

    2015-08-01

    Since the beginning of the transcatheter aortic valve implantation (TAVI) era, many prosthetic valves have entered clinical practice. TAVI prostheses differ regarding stent design and some may potentially interfere with diagnostic or interventional catheters. The aim of our analysis was to evaluate the feasibility of coronary angiography (CA) or percutaneous coronary intervention (PCI) in patients with prior TAVI. From 2011 to 2014, 1,000 patients were treated by TAVI at our center using eight different valve prostheses (Symetis ACURATE TA and ACURATE TF; Medtronic CoreValve and Engager; JenaValve, SJM Portico; Edwards Lifesciences SAPIEN and SAPIEN XT). In this analysis, all patients were included who underwent either CA or PCI after TAVI. CA or PCI were rated as fully feasible when coronary ostia could be fully intubated, partially feasible when coronary arteries could be displayed only unselectively or unfeasible when coronary arteries could not be displayed. A total of 35 patients underwent CA/PCI after TAVI at our hospital. In all patients with valves implanted in a subcoronary position (SAPIEN n = 19; JenaValve n = 1), selective intubation was feasible using standard catheters. Out of 15 patients with valve types that are placed over the coronary ostia (CoreValve n = 10, ACURATE n = 4, Portico n = 1), selective intubation of coronary arteries was not possible in 9 cases, even with the use of different diagnostic catheters. Full accessibility was possible only in 3 cases. In 2 cases, display of the right CA was only feasible using unselective aortography. In 1 case, coronary arteries could not be displayed at all immediately after a valve-in-valve procedure. CA or PCI after TAVI is usually feasible. Devices that are placed in a partially supracoronary position, however, can interfere with diagnostic or guiding catheters and impede straightforward intervention, especially when the prosthesis is not implanted in the correct position.

  8. Evaluation of motion artifact metrics for coronary CT angiography.

    PubMed

    Ma, Hongfeng; Gros, Eric; Szabo, Aniko; Baginski, Scott G; Laste, Zachary R; Kulkarni, Naveen M; Okerlund, Darin; Schmidt, Taly G

    2018-02-01

    This study quantified the performance of coronary artery motion artifact metrics relative to human observer ratings. Motion artifact metrics have been used as part of motion correction and best-phase selection algorithms for Coronary Computed Tomography Angiography (CCTA). However, the lack of ground truth makes it difficult to validate how well the metrics quantify the level of motion artifact. This study investigated five motion artifact metrics, including two novel metrics, using a dynamic phantom, clinical CCTA images, and an observer study that provided ground-truth motion artifact scores from a series of pairwise comparisons. Five motion artifact metrics were calculated for the coronary artery regions on both phantom and clinical CCTA images: positivity, entropy, normalized circularity, Fold Overlap Ratio (FOR), and Low-Intensity Region Score (LIRS). CT images were acquired of a dynamic cardiac phantom that simulated cardiac motion and contained six iodine-filled vessels of varying diameter and with regions of soft plaque and calcifications. Scans were repeated with different gantry start angles. Images were reconstructed at five phases of the motion cycle. Clinical images were acquired from 14 CCTA exams with patient heart rates ranging from 52 to 82 bpm. The vessel and shading artifacts were manually segmented by three readers and combined to create ground-truth artifact regions. Motion artifact levels were also assessed by readers using a pairwise comparison method to establish a ground-truth reader score. The Kendall's Tau coefficients were calculated to evaluate the statistical agreement in ranking between the motion artifacts metrics and reader scores. Linear regression between the reader scores and the metrics was also performed. On phantom images, the Kendall's Tau coefficients of the five motion artifact metrics were 0.50 (normalized circularity), 0.35 (entropy), 0.82 (positivity), 0.77 (FOR), 0.77(LIRS), where higher Kendall's Tau signifies higher

  9. Unstable angina with normal coronary angiography in hyperthyroidism: a case report.

    PubMed

    Lin, Tsung-Hsien; Su, Ho-Ming; Voon, Wen-Chol; Lai, Wen-Ter; Sheu, Sheng-Hsiung

    2005-01-01

    Hyperthyroidism is associated with an increase in myocardial oxygen consumption that, due to an imbalance of oxygen demand and supply, can cause angina. However, subclinical hyperthyroidism rarely presents as chest pain in the resting state. Herein, we present a case of subclinical hyperthyroidism involving a 58-year-old male who complained of frequent chest tightness and typical electrocardiographic changes while in a resting state. Coronary angiography showed no significant lesion. Laboratory data showed that the patient suffered from hyperthyroidism, for which he was successfully treated with anti-thyroid agents. We are reminded that typical chest pain might be the first symptom of hyperthyroidism.

  10. 3D/3D registration of coronary CTA and biplane XA reconstructions for improved image guidance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dibildox, Gerardo, E-mail: g.dibildox@erasmusmc.nl; Baka, Nora; Walsum, Theo van

    2014-09-15

    Purpose: The authors aim to improve image guidance during percutaneous coronary interventions of chronic total occlusions (CTO) by providing information obtained from computed tomography angiography (CTA) to the cardiac interventionist. To this end, the authors investigate a method to register a 3D CTA model to biplane reconstructions. Methods: The authors developed a method for registering preoperative coronary CTA with intraoperative biplane x-ray angiography (XA) images via 3D models of the coronary arteries. The models are extracted from the CTA and biplane XA images, and are temporally aligned based on CTA reconstruction phase and XA ECG signals. Rigid spatial alignment ismore » achieved with a robust probabilistic point set registration approach using Gaussian mixture models (GMMs). This approach is extended by including orientation in the Gaussian mixtures and by weighting bifurcation points. The method is evaluated on retrospectively acquired coronary CTA datasets of 23 CTO patients for which biplane XA images are available. Results: The Gaussian mixture model approach achieved a median registration accuracy of 1.7 mm. The extended GMM approach including orientation was not significantly different (P > 0.1) but did improve robustness with regards to the initialization of the 3D models. Conclusions: The authors demonstrated that the GMM approach can effectively be applied to register CTA to biplane XA images for the purpose of improving image guidance in percutaneous coronary interventions.« less

  11. Head-to-head comparison of adaptive statistical and model-based iterative reconstruction algorithms for submillisievert coronary CT angiography.

    PubMed

    Benz, Dominik C; Fuchs, Tobias A; Gräni, Christoph; Studer Bruengger, Annina A; Clerc, Olivier F; Mikulicic, Fran; Messerli, Michael; Stehli, Julia; Possner, Mathias; Pazhenkottil, Aju P; Gaemperli, Oliver; Kaufmann, Philipp A; Buechel, Ronny R

    2018-02-01

    Iterative reconstruction (IR) algorithms allow for a significant reduction in radiation dose of coronary computed tomography angiography (CCTA). We performed a head-to-head comparison of adaptive statistical IR (ASiR) and model-based IR (MBIR) algorithms to assess their impact on quantitative image parameters and diagnostic accuracy for submillisievert CCTA. CCTA datasets of 91 patients were reconstructed using filtered back projection (FBP), increasing contributions of ASiR (20, 40, 60, 80, and 100%), and MBIR. Signal and noise were measured in the aortic root to calculate signal-to-noise ratio (SNR). In a subgroup of 36 patients, diagnostic accuracy of ASiR 40%, ASiR 100%, and MBIR for diagnosis of coronary artery disease (CAD) was compared with invasive coronary angiography. Median radiation dose was 0.21 mSv for CCTA. While increasing levels of ASiR gradually reduced image noise compared with FBP (up to - 48%, P < 0.001), MBIR provided largest noise reduction (-79% compared with FBP) outperforming ASiR (-59% compared with ASiR 100%; P < 0.001). Increased noise and lower SNR with ASiR 40% and ASiR 100% resulted in substantially lower diagnostic accuracy to detect CAD as diagnosed by invasive coronary angiography compared with MBIR: sensitivity and specificity were 100 and 37%, 100 and 57%, and 100 and 74% for ASiR 40%, ASiR 100%, and MBIR, respectively. MBIR offers substantial noise reduction with increased SNR, paving the way for implementation of submillisievert CCTA protocols in clinical routine. In contrast, inferior noise reduction by ASiR negatively affects diagnostic accuracy of submillisievert CCTA for CAD detection. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.

  12. Preventive effect of pretreatment with intravenous nicorandil on contrast-induced nephropathy in patients with renal dysfunction undergoing coronary angiography (PRINCIPLE Study).

    PubMed

    Ko, Young-Guk; Lee, Byoung-Kwon; Kang, Woong Chol; Moon, Jae-Youn; Cho, Yun Hyeong; Choi, Seong Hun; Hong, Myeong-Ki; Jang, Yangsoo; Kim, Jong-Youn; Min, Pil-Ki; Kwon, Hyuck-Moon

    2013-07-01

    To investigate the effect of pretreatment with intravenous nicorandil on the incidence of contrast-induced nephropathy (CIN) in patients with renal dysfunction undergoing coronary angiography. This randomized controlled multicenter study enrolled a total of 166 patients (nicorandil n=81; control n=85) with an estimated glomerular filtration rate <60 mL/min. Nicorandil 12 mg dissolved in 100 mL of 0.9% saline was administered intravenously for 30 minutes just prior to coronary angiography in the nicorandil group. The same volume of only saline was given to the control group. The primary endpoint was the incidence of CIN, defined as >0.5 mg/dL increase or >25% rise in serum creatinine (SCr) concentration within 48 hours of contrast exposure compared to baseline. The final analysis included 149 patients (nicorandil n=73; control n=76). The baseline characteristics and the total volume of the used contrast (Iodixanol, 125.6±69.1 mL vs. 126.9±74.6 mL, p=0.916) were similar between the two groups. The incidence of CIN also did not differ between the nicorandil and control groups (6.8% vs. 6.6%, p=0.794). There was no difference between the two groups in the relative change in SCr from baseline to peak level within 48 hours after coronary angiography (-1.58±24.07% vs. 0.96±17.49%, p=0.464), although the nicorandil group showed less absolute change in SCr than the control group (-0.01±0.43 mg/mL vs. 0.02±0.31 mg/mL, p=0.005). Prophylactic intravenous infusion of nicorandil did not decrease the incidence of CIN in patients with renal dysfunction undergoing coronary angiography.

  13. Carbon dioxide coronary angiography: A mechanical feasibility study with a cardiovascular simulator

    NASA Astrophysics Data System (ADS)

    Corazza, Ivan; Taglieri, Nevio; Pirazzini, Edoardo; Rossi, Pier Luca; Lombi, Alessandro; Scalise, Filippo; Caridi, James G.; Zannoli, Romano

    2018-01-01

    The aim of this study was to carry out a bench evaluation of the biomechanical feasibility of carbon dioxide (CO2) coronary arteriography. Many patients among the aging population of individuals requiring cardiac intervention have underlying renal insufficiency making them susceptible to contrast-induced nephropathy. To include those patients, it is imperative to find an alternative and safe technique to perform coronary imaging on cardiac ischemic patients. As CO2 angiography has no renal toxicity, it may be a possible solution offering good imaging with negligible collateral effects. Theoretically, by carefully controlling the gas injection process, new automatic injectors may avoid gas reflux into the aorta and possible cerebral damage. A feasibility study is mandatory. A mechanical mock of the coronary circulation was developed and employed. CO2 was injected into the coronary ostium with 2 catheters (2F and 6F) and optical images of bubbles flowing inside the vessels at different injection pressures were recorded. The gas behavior was then carefully studied for quantitative and qualitative analysis. Video recordings showed that CO2 injection at a precise pressure in the interval between the arterial dicrotic notch and the minimum diastolic value does not result in gas reflow into the aorta. Gas reflow was easier to control with the smaller catheter, but the gas bubbles were smaller with different vascular filling. Our simulation demonstrates that carefully selected injection parameters allow CO2 coronary imaging without any risk of gas reflux into the aorta.

  14. Socioeconomic Factors and Severity of Coronary Artery Disease in Patients Undergoing Coronary Angiography: A Multicentre Study of Arabian Gulf States.

    PubMed

    Daoulah, Amin; Elkhateeb, Osama E; Nasseri, S Ali; Al-Murayeh, Mushabab; Al-Kaabi, Salem; Lotfi, Amir; Alama, Mohamed N; Al-Faifi, Salem M; Haddara, Mamdouh; Dixon, Ciaran M; Alzahrani, Ibrahim S; Alghamdi, Abdullah A; Ahmed, Waleed; Fathey, Adnan; Haq, Ejazul; Alsheikh-Ali, Alawi A

    2017-01-01

    Coronary artery disease (CAD) is a leading cause of death worldwide. The association of socioeconomic status with CAD is supported by numerous epidemiological studies. Whether such factors also impact the number of diseased coronary vessels and its severity is not well established. We conducted a prospective multicentre, multi-ethnic, cross sectional observational study of consecutive patients undergoing coronary angiography (CAG) at 5 hospitals in the Kingdom of Saudi Arabia and the United Arab Emirates. Baseline demographics, socioeconomic, and clinical variables were collected for all patients. Significant CAD was defined as ≥70% luminal stenosis in a major epicardial vessel. Left main disease (LMD) was defined as ≥50% stenosis in the left main coronary artery. Multi-vessel disease (MVD) was defined as having >1 significant CAD. Of 1,068 patients (age 59 ± 13, female 28%, diabetes 56%, hypertension 60%, history of CAD 43%), 792 (74%) were from urban and remainder (26%) from rural communities. Patients from rural centres were older (61 ± 12 vs 58 ± 13), and more likely to have a history of diabetes (63 vs 54%), hypertension (74 vs 55%), dyslipidaemia (78 vs 59%), CAD (50 vs 41%) and percutaneous coronary intervention (PCI) (27 vs 21%). The two groups differed significantly in terms of income level, employment status and indication for angiography. After adjusting for baseline differences, patients living in a rural area were more likely to have significant CAD (adjusted OR 2.40 [1.47, 3.97]), MVD (adjusted OR 1.76 [1.18, 2.63]) and LMD (adjusted OR 1.71 [1.04, 2.82]). Higher income was also associated with a higher risk for significant CAD (adjusted OR 6.97 [2.30, 21.09]) and MVD (adjusted OR 2.49 [1.11, 5.56]), while unemployment was associated with a higher risk of significant CAD (adjusted OR 2.21, [1.27, 3.85]). Communal and socioeconomic factors are associated with higher odds of significant CAD and MVD in the group of patients referred for CAG. The

  15. Socioeconomic Factors and Severity of Coronary Artery Disease in Patients Undergoing Coronary Angiography: A Multicentre Study of Arabian Gulf States

    PubMed Central

    Daoulah, Amin; Elkhateeb, Osama E.; Nasseri, S. Ali; Al-Murayeh, Mushabab; Al-kaabi, Salem; Lotfi, Amir; Alama, Mohamed N.; Al-Faifi, Salem M.; Haddara, Mamdouh; Dixon, Ciaran M.; Alzahrani, Ibrahim S.; Alghamdi, Abdullah A.; Ahmed, Waleed; Fathey, Adnan; Haq, Ejazul; Alsheikh-Ali, Alawi A

    2017-01-01

    Introduction: Coronary artery disease (CAD) is a leading cause of death worldwide. The association of socioeconomic status with CAD is supported by numerous epidemiological studies. Whether such factors also impact the number of diseased coronary vessels and its severity is not well established. Materials and Methods: We conducted a prospective multicentre, multi-ethnic, cross sectional observational study of consecutive patients undergoing coronary angiography (CAG) at 5 hospitals in the Kingdom of Saudi Arabia and the United Arab Emirates. Baseline demographics, socioeconomic, and clinical variables were collected for all patients. Significant CAD was defined as ≥70% luminal stenosis in a major epicardial vessel. Left main disease (LMD) was defined as ≥50% stenosis in the left main coronary artery. Multi-vessel disease (MVD) was defined as having >1 significant CAD. Results: Of 1,068 patients (age 59 ± 13, female 28%, diabetes 56%, hypertension 60%, history of CAD 43%), 792 (74%) were from urban and remainder (26%) from rural communities. Patients from rural centres were older (61 ± 12 vs 58 ± 13), and more likely to have a history of diabetes (63 vs 54%), hypertension (74 vs 55%), dyslipidaemia (78 vs 59%), CAD (50 vs 41%) and percutaneous coronary intervention (PCI) (27 vs 21%). The two groups differed significantly in terms of income level, employment status and indication for angiography. After adjusting for baseline differences, patients living in a rural area were more likely to have significant CAD (adjusted OR 2.40 [1.47, 3.97]), MVD (adjusted OR 1.76 [1.18, 2.63]) and LMD (adjusted OR 1.71 [1.04, 2.82]). Higher income was also associated with a higher risk for significant CAD (adjusted OR 6.97 [2.30, 21.09]) and MVD (adjusted OR 2.49 [1.11, 5.56]), while unemployment was associated with a higher risk of significant CAD (adjusted OR 2.21, [1.27, 3.85]). Conclusion: Communal and socioeconomic factors are associated with higher odds of significant

  16. Coronary Artery Disease: Analysis of Diagnostic Performance of CT Perfusion and MR Perfusion Imaging in Comparison with Quantitative Coronary Angiography and SPECT-Multicenter Prospective Trial.

    PubMed

    Rief, Matthias; Chen, Marcus Y; Vavere, Andrea L; Kendziora, Benjamin; Miller, Julie M; Bandettini, W Patricia; Cox, Christopher; George, Richard T; Lima, João; Di Carli, Marcelo; Plotkin, Michail; Zimmermann, Elke; Laule, Michael; Schlattmann, Peter; Arai, Andrew E; Dewey, Marc

    2018-02-01

    Purpose To compare the diagnostic performance of stress myocardial computed tomography (CT) perfusion with that of stress myocardial magnetic resonance (MR) perfusion imaging in the detection of coronary artery disease (CAD). Materials and Methods All patients gave written informed consent prior to inclusion in this institutional review board-approved study. This two-center substudy of the prospective Combined Noninvasive Coronary Angiography and Myocardial Perfusion Imaging Using 320-Detector Row Computed Tomography (CORE320) multicenter trial included 92 patients (mean age, 63.1 years ± 8.1 [standard deviation]; 73% male). All patients underwent perfusion CT and perfusion MR imaging with either adenosine or regadenoson stress. The predefined reference standards were combined quantitative coronary angiography (QCA) and single-photon emission CT (SPECT) or QCA alone. Results from coronary CT angiography were not included, and diagnostic performance was evaluated with the Mantel-Haenszel test stratified by disease status. Results The prevalence of CAD was 39% (36 of 92) according to QCA and SPECT and 64% (59 of 92) according to QCA alone. When compared with QCA and SPECT, per-patient diagnostic accuracy of perfusion CT and perfusion MR imaging was 63% (58 of 92) and 75% (69 of 92), respectively (P = .11); sensitivity was 92% (33 of 36) and 83% (30 of 36), respectively (P = .45); and specificity was 45% (25 of 56) and 70% (39 of 56), respectively (P < .01). When compared with QCA alone, diagnostic accuracy of CT perfusion and MR perfusion imaging was 82% (75 of 92) and 74% (68 of 92), respectively (P = .27); sensitivity was 90% (53 of 59) and 69% (41 of 59), respectively (P < .01); and specificity was 67% (22 of 33) and 82% (27 of 33), respectively (P = .27). Conclusion This multicenter study shows that the diagnostic performance of perfusion CT is similar to that of perfusion MR imaging in the detection of CAD. © RSNA, 2017 Online supplemental material is

  17. Systemic Effects of Intracoronary Nitroglycerin during Coronary Angiography in Children after Heart Transplantation

    PubMed Central

    Lara, Diego A.; Olive, Mary K.; George, James F.; Brown, Robert N.; Carlo, Waldemar F.; Colvin, Edward V.; Steenwyck, Brad L.

    2014-01-01

    Coronary spasm during coronary angiography for vasculopathy in children can be prevented by the intracoronary administration of nitroglycerin. We reviewed the anesthesia and catheterization reports and charts for pediatric transplant recipients who underwent angiography from 2005 through 2010. Correlation analysis was used to study the relation of post-injection systolic blood pressure (SBP) to nitroglycerin dose. Forty-one angiographic evaluations were performed on 25 patients (13 male and 12 female). Mean age was 9.9 ± 3.2 years (range, 3.3–16.1 yr). The mean total dose of nitroglycerin was 2.93 ± 1.60 µg/kg (range, 1–8 µg/kg). There was a significant drop between the baseline SBP (mean, 106 ± 21.6 mmHg) and the lowest mean SBP before nitroglycerin administration (78 ± 13.2, P <0.0001, paired t test). There was no significant additional change in SBP (mean after nitroglycerin administration, 80.7 ± 13.1 mmHg; P = 0.2). There was a significant drop in lowest heart rate between baseline (109 ± 16.5 beats/min) and before nitroglycerin administration (89 ± 14.3 beats/min; P <0.0001, paired t test). There was no significant additional change in heart rate (mean heart rate after nitroglycerin, 84 ± 17.7 beats/min; P = 0.09). There were 2 interventions for SBP before nitroglycerin and 2 after nitroglycerin. One child experienced a transient ST-T–segment change during angiography after nitroglycerin. In the highest dose range, the additional decrease in SBP was 7.2 mmHg (P=0.03). Routine intracoronary nitroglycerin administration in this dose range produced no significant changes in SBP or heart rate in children. PMID:24512395

  18. Advanced Respiratory Motion Compensation for Coronary MR Angiography

    PubMed Central

    Henningsson, Markus; Botnar, Rene M.

    2013-01-01

    Despite technical advances, respiratory motion remains a major impediment in a substantial amount of patients undergoing coronary magnetic resonance angiography (CMRA). Traditionally, respiratory motion compensation has been performed with a one-dimensional respiratory navigator positioned on the right hemi-diaphragm, using a motion model to estimate and correct for the bulk respiratory motion of the heart. Recent technical advancements has allowed for direct respiratory motion estimation of the heart, with improved motion compensation performance. Some of these new methods, particularly using image-based navigators or respiratory binning, allow for more advanced motion correction which enables CMRA data acquisition throughout most or all of the respiratory cycle, thereby significantly reducing scan time. This review describes the three components typically involved in most motion compensation strategies for CMRA, including respiratory motion estimation, gating and correction, and how these processes can be utilized to perform advanced respiratory motion compensation. PMID:23708271

  19. CT coronary angiography: impact of adapted statistical iterative reconstruction (ASIR) on coronary stenosis and plaque composition analysis.

    PubMed

    Fuchs, Tobias A; Fiechter, Michael; Gebhard, Cathérine; Stehli, Julia; Ghadri, Jelena R; Kazakauskaite, Egle; Herzog, Bernhard A; Husmann, Lars; Gaemperli, Oliver; Kaufmann, Philipp A

    2013-03-01

    To assess the impact of adaptive statistical iterative reconstruction (ASIR) on coronary plaque volume and composition analysis as well as on stenosis quantification in high definition coronary computed tomography angiography (CCTA). We included 50 plaques in 29 consecutive patients who were referred for the assessment of known or suspected coronary artery disease (CAD) with contrast-enhanced CCTA on a 64-slice high definition CT scanner (Discovery HD 750, GE Healthcare). CCTA scans were reconstructed with standard filtered back projection (FBP) with no ASIR (0 %) or with increasing contributions of ASIR, i.e. 20, 40, 60, 80 and 100 % (no FBP). Plaque analysis (volume, components and stenosis degree) was performed using a previously validated automated software. Mean values for minimal diameter and minimal area as well as degree of stenosis did not change significantly using different ASIR reconstructions. There was virtually no impact of reconstruction algorithms on mean plaque volume or plaque composition (e.g. soft, intermediate and calcified component). However, with increasing ASIR contribution, the percentage of plaque volume component between 401 and 500 HU decreased significantly (p < 0.05). Modern image reconstruction algorithms such as ASIR, which has been developed for noise reduction in latest high resolution CCTA scans, can be used reliably without interfering with the plaque analysis and stenosis severity assessment.

  20. Indocyanine green angiography of juvenile X-linked retinoschisis.

    PubMed

    Souied, Eric H; Goritsa, Anna; Querques, Giuseppe; Coscas, Gabriel; Soubrane, Gisele

    2005-09-01

    In juvenile X-linked retinoschisis (XLRS), fluorescein angiography is usually unremarkable and contributes poorly to the diagnosis. However, indocyanine green (ICG) angiography features in eyes that are affected with XLRS were not yet described. Retrospective observational case series. A complete ophthalmologic examination that included ICG angiography was performed on three unrelated male patients (six eyes) who were 15, 22, and 48 years old. A distinct hyperfluorescent stellate pattern in the macular area that was associated with radial lines of hypofluorescence that were centered on the foveola was observed on the early phase of ICG examination (six of six eyes). This feature disappeared on the late phase of ICG examination. On these six XLRS eyes, early phases of ICG examination revealed an unusual radial aspect on the macula. This finding suggests that ICG angiography may be useful for the diagnosis of XLRS.

  1. Diagnostic performance of computed tomography coronary angiography (from the Prospective National Multicenter Multivendor EVASCAN Study).

    PubMed

    Gueret, Pascal; Deux, Jean-François; Bonello, Laurent; Sarran, Anthony; Tron, Christophe; Christiaens, Luc; Dacher, Jean-Nicolas; Bertrand, David; Leborgne, Laurent; Renard, Cedric; Caussin, Christophe; Cluzel, Philippe; Helft, Gerard; Crochet, Dominique; Vernhet-Kovacsik, Hélène; Chabbert, Valérie; Ferrari, Emile; Gilard, Martine; Willoteaux, Serge; Furber, Alain; Barone-Rochette, Gilles; Jankowski, Adrien; Douek, Philippe; Mousseaux, Elie; Sirol, Marc; Niarra, Ralph; Chatellier, Gilles; Laissy, Jean-Pierre

    2013-02-15

    Computed tomographic coronary angiography (CTCA) has been proposed as a noninvasive test for significant coronary artery disease (CAD), but only limited data are available from prospective multicenter trials. The goal of this study was to establish the diagnostic accuracy of CTCA compared to coronary angiography (CA) in a large population of symptomatic patients with clinical indications for coronary imaging. This national, multicenter study was designed to prospectively evaluate stable patients able to undergo CTCA followed by conventional CA. Data from CTCA and CA were analyzed in a blinded fashion at central core laboratories. The main outcome was the evaluation of patient-, vessel-, and segment-based diagnostic performance of CTCA to detect or rule out significant CAD (≥50% luminal diameter reduction). Of 757 patients enrolled, 746 (mean age 61 ± 12 years, 71% men) were analyzed. They underwent CTCA followed by CA 1.7 ± 0.8 days later using a 64-detector scanner. The prevalence of significant CAD in native coronary vessels by CA was 54%. The rate of nonassessable segments by CTCA was 6%. In a patient-based analysis, sensitivity, specificity, positive and negative predictive values, and positive and negative likelihood ratios of CTCA were 91%, 50%, 68%, 83%, 1.82, and 0.18, respectively. The strongest predictors of false-negative results on CTCA were high estimated pretest probability of CAD (odds ratio [OR] 1.97, p <0.001), male gender (OR 1.5, p <0.002), diabetes (OR 1.5, p <0.0001), and age (OR 1.2, p <0.0001). In conclusion, in this large multicenter study, CTCA identified significant CAD with high sensitivity. However, in routine clinical practice, each patient should be individually evaluated, and the pretest probability of obstructive CAD should be taken into account when deciding which method, CTCA or CA, to use to diagnose its presence and severity. Copyright © 2013 Elsevier Inc. All rights reserved.

  2. Technical feasibility and validation of a coronary artery calcium scoring system using CT coronary angiography images.

    PubMed

    Pavitt, Christopher W; Harron, Katie; Lindsay, Alistair C; Zielke, Sayeh; Ray, Robin; Gordon, Daniel; Rubens, Michael B; Padley, Simon P; Nicol, Edward D

    2016-05-01

    We validate a novel CT coronary angiography (CCTA) coronary calcium scoring system. Calcium was quantified on CCTA images using a new patient-specific attenuation threshold: mean + 2SD of intra-coronary contrast density (HU). Using 335 patient data sets a conversion factor (CF) for predicting CACS from CCTA scores (CCTAS) was derived and validated in a separate cohort (n = 168). Bland-Altman analysis and weighted kappa for MESA centiles and Agatston risk groupings were calculated. Multivariable linear regression yielded a CF: CACS = (1.185 × CCTAS) + (0.002 × CCTAS × attenuation threshold). When applied to CCTA data sets there was excellent correlation (r = 0.95; p < 0.0001) and agreement (mean difference -10.4 [95% limits of agreement -258.9 to 238.1]) with traditional calcium scores. Agreement was better for calcium scores below 500; however, MESA percentile agreement was better for high risk patients. Risk stratification was excellent (Agatston groups k = 0.88 and MESA centiles k = 0.91). Eliminating the dedicated CACS scan decreased patient radiation exposure by approximately one-third. CCTA calcium scores can accurately predict CACS using a simple, individualized, semiautomated approach reducing acquisition time and radiation exposure when evaluating patients for CAD. This method is not affected by the ROI location, imaging protocol, or tube voltage strengthening its clinical applicability. • Coronary calcium scores can be reliably determined on contrast-enhanced cardiac CT • This score can accurately risk stratify patients • Elimination of a dedicated calcium scan reduces patient radiation by a third.

  3. Automatic segmentation of coronary arteries from computed tomography angiography data cloud using optimal thresholding

    NASA Astrophysics Data System (ADS)

    Ansari, Muhammad Ahsan; Zai, Sammer; Moon, Young Shik

    2017-01-01

    Manual analysis of the bulk data generated by computed tomography angiography (CTA) is time consuming, and interpretation of such data requires previous knowledge and expertise of the radiologist. Therefore, an automatic method that can isolate the coronary arteries from a given CTA dataset is required. We present an automatic yet effective segmentation method to delineate the coronary arteries from a three-dimensional CTA data cloud. Instead of a region growing process, which is usually time consuming and prone to leakages, the method is based on the optimal thresholding, which is applied globally on the Hessian-based vesselness measure in a localized way (slice by slice) to track the coronaries carefully to their distal ends. Moreover, to make the process automatic, we detect the aorta using the Hough transform technique. The proposed segmentation method is independent of the starting point to initiate its process and is fast in the sense that coronary arteries are obtained without any preprocessing or postprocessing steps. We used 12 real clinical datasets to show the efficiency and accuracy of the presented method. Experimental results reveal that the proposed method achieves 95% average accuracy.

  4. Clinical evaluation of new automatic coronary-specific best cardiac phase selection algorithm for single-beat coronary CT angiography.

    PubMed

    Wang, Hui; Xu, Lei; Fan, Zhanming; Liang, Junfu; Yan, Zixu; Sun, Zhonghua

    2017-01-01

    The aim of this study was to evaluate the workflow efficiency of a new automatic coronary-specific reconstruction technique (Smart Phase, GE Healthcare-SP) for selection of the best cardiac phase with least coronary motion when compared with expert manual selection (MS) of best phase in patients with high heart rate. A total of 46 patients with heart rates above 75 bpm who underwent single beat coronary computed tomography angiography (CCTA) were enrolled in this study. CCTA of all subjects were performed on a 256-detector row CT scanner (Revolution CT, GE Healthcare, Waukesha, Wisconsin, US). With the SP technique, the acquired phase range was automatically searched in 2% phase intervals during the reconstruction process to determine the optimal phase for coronary assessment, while for routine expert MS, reconstructions were performed at 5% intervals and a best phase was manually determined. The reconstruction and review times were recorded to measure the workflow efficiency for each method. Two reviewers subjectively assessed image quality for each coronary artery in the MS and SP reconstruction volumes using a 4-point grading scale. The average HR of the enrolled patients was 91.1±19.0bpm. A total of 204 vessels were assessed. The subjective image quality using SP was comparable to that of the MS, 1.45±0.85 vs 1.43±0.81 respectively (p = 0.88). The average time was 246 seconds for the manual best phase selection, and 98 seconds for the SP selection, resulting in average time saving of 148 seconds (60%) with use of the SP algorithm. The coronary specific automatic cardiac best phase selection technique (Smart Phase) improves clinical workflow in high heart rate patients and provides image quality comparable with manual cardiac best phase selection. Reconstruction of single-beat CCTA exams with SP can benefit the users with less experienced in CCTA image interpretation.

  5. Decision analysis in clinical cardiology: When is coronary angiography required in aortic stenosis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Georgeson, S.; Meyer, K.B.; Pauker, S.G.

    1990-03-15

    Decision analysis offers a reproducible, explicit approach to complex clinical decisions. It consists of developing a model, typically a decision tree, that separates choices from chances and that specifies and assigns relative values to outcomes. Sensitivity analysis allows exploration of alternative assumptions. Cost-effectiveness analysis shows the relation between dollars spent and improved health outcomes achieved. In a tutorial format, this approach is applied to the decision whether to perform coronary angiography in a patient who requires aortic valve replacement for critical aortic stenosis.

  6. Plaque imaging with CT—a comprehensive review on coronary CT angiography based risk assessment

    PubMed Central

    Kolossváry, Márton; Szilveszter, Bálint; Merkely, Béla

    2017-01-01

    CT based technologies have evolved considerably in recent years. Coronary CT angiography (CTA) provides robust assessment of coronary artery disease (CAD). Early coronary CTA imaging—as a gate-keeper of invasive angiography—has focused on the presence of obstructive stenosis. Coronary CTA is currently the only non-invasive imaging modality for the evaluation of non-obstructive CAD, which has been shown to contribute to adverse cardiac events. Importantly, improved spatial resolution of CT scanners and novel image reconstruction algorithms enable the quantification and characterization of atherosclerotic plaques. State-of-the-art CT imaging can therefore reliably assess the extent of CAD and differentiate between various plaque features. Recent studies have demonstrated the incremental prognostic value of adverse plaque features over luminal stenosis. Comprehensive coronary plaque assessment holds potential to significantly improve individual risk assessment incorporating adverse plaque characteristics, the extent and severity of atherosclerotic plaque burden. As a result, several coronary CTA based composite risk scores have been proposed recently to determine patients at high risk for adverse events. Coronary CTA became a promising modality for the evaluation of functional significance of coronary lesions using CT derived fractional flow reserve (FFR-CT) and/or rest/dynamic myocardial CT perfusion. This could lead to substantial reduction in unnecessary invasive catheterization procedures and provide information on ischemic burden of CAD. Discordance between the degree of stenosis and ischemia has been recognized in clinical landmark trials using invasive FFR. Both lesion stenosis and composition are possibly related to myocardial ischemia. The evaluation of lesion-specific ischemia using combined functional and morphological plaque information could ultimately improve the diagnostic performance of CTA and thus patient care. In this review we aimed to

  7. Can image enhancement allow radiation dose to be reduced whilst maintaining the perceived diagnostic image quality required for coronary angiography?

    PubMed Central

    Joshi, Anuja; Gislason-Lee, Amber J; Keeble, Claire; Sivananthan, Uduvil M

    2017-01-01

    Objective: The aim of this research was to quantify the reduction in radiation dose facilitated by image processing alone for percutaneous coronary intervention (PCI) patient angiograms, without reducing the perceived image quality required to confidently make a diagnosis. Methods: Incremental amounts of image noise were added to five PCI angiograms, simulating the angiogram as having been acquired at corresponding lower dose levels (10–89% dose reduction). 16 observers with relevant experience scored the image quality of these angiograms in 3 states—with no image processing and with 2 different modern image processing algorithms applied. These algorithms are used on state-of-the-art and previous generation cardiac interventional X-ray systems. Ordinal regression allowing for random effects and the delta method were used to quantify the dose reduction possible by the processing algorithms, for equivalent image quality scores. Results: Observers rated the quality of the images processed with the state-of-the-art and previous generation image processing with a 24.9% and 15.6% dose reduction, respectively, as equivalent in quality to the unenhanced images. The dose reduction facilitated by the state-of-the-art image processing relative to previous generation processing was 10.3%. Conclusion: Results demonstrate that statistically significant dose reduction can be facilitated with no loss in perceived image quality using modern image enhancement; the most recent processing algorithm was more effective in preserving image quality at lower doses. Advances in knowledge: Image enhancement was shown to maintain perceived image quality in coronary angiography at a reduced level of radiation dose using computer software to produce synthetic images from real angiograms simulating a reduction in dose. PMID:28124572

  8. Sex Differences in Percutaneous Coronary Intervention-Insights From the Coronary Angiography and PCI Registry of the German Society of Cardiology.

    PubMed

    Heer, Tobias; Hochadel, Matthias; Schmidt, Karin; Mehilli, Julinda; Zahn, Ralf; Kuck, Karl-Heinz; Hamm, Christian; Böhm, Michael; Ertl, Georg; Hoffmeister, Hans Martin; Sack, Stefan; Senges, Jochen; Massberg, Steffen; Gitt, Anselm K; Zeymer, Uwe

    2017-03-20

    Several studies have suggested sex-related differences in diagnostic and invasive therapeutic coronary procedures. Data from consecutive patients who were enrolled in the Coronary Angiography and PCI Registry of the German Society of Cardiology were analyzed. We aimed to compare sex-related differences in in-hospital outcomes of patients undergoing percutaneous coronary intervention (PCI) for stable coronary artery disease, non-ST elevation acute coronary syndromes, ST elevation myocardial infarction, and cardiogenic shock. From 2007 until the end of 2009 data from 185 312 PCIs were prospectively registered: 27.9% of the PCIs were performed in women. Primary PCI success rate was identical between the sexes (94%). There were no sex-related differences in hospital mortality among patients undergoing PCI for stable coronary artery disease, non-ST elevation acute coronary syndromes, or cardiogenic shock except among ST elevation myocardial infarction patients. Compared to men, women undergoing primary PCI for ST elevation myocardial infarction have a higher risk of in-hospital death, age-adjusted odds ratio (1.19, 95% CI 1.06-1.33), and risk of ischemic cardiac and cerebrovascular events (death, myocardial infarction, transient ischemic attack/stroke), (age-adjusted odds ratio 1.19, 95% CI 1.16-1.29). Furthermore, access-related complications were twice as high in women, irrespective of the indication. Despite identical technical success rates of PCI between the 2 sexes, women with PCI for ST elevation myocardial infarction have a 20% higher age-adjusted risk of death and of ischemic cardiac and cerebrovascular events. Further research is needed to determine the reasons for these differences. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  9. Quantitative coronary plaque analysis predicts high-risk plaque morphology on coronary computed tomography angiography: results from the ROMICAT II trial.

    PubMed

    Liu, Ting; Maurovich-Horvat, Pál; Mayrhofer, Thomas; Puchner, Stefan B; Lu, Michael T; Ghemigian, Khristine; Kitslaar, Pieter H; Broersen, Alexander; Pursnani, Amit; Hoffmann, Udo; Ferencik, Maros

    2018-02-01

    Semi-automated software can provide quantitative assessment of atherosclerotic plaques on coronary CT angiography (CTA). The relationship between established qualitative high-risk plaque features and quantitative plaque measurements has not been studied. We analyzed the association between quantitative plaque measurements and qualitative high-risk plaque features on coronary CTA. We included 260 patients with plaque who underwent coronary CTA in the Rule Out Myocardial Infarction/Ischemia Using Computer Assisted Tomography (ROMICAT) II trial. Quantitative plaque assessment and qualitative plaque characterization were performed on a per coronary segment basis. Quantitative coronary plaque measurements included plaque volume, plaque burden, remodeling index, and diameter stenosis. In qualitative analysis, high-risk plaque was present if positive remodeling, low CT attenuation plaque, napkin-ring sign or spotty calcium were detected. Univariable and multivariable logistic regression analyses were performed to assess the association between quantitative and qualitative high-risk plaque assessment. Among 888 segments with coronary plaque, high-risk plaque was present in 391 (44.0%) segments by qualitative analysis. In quantitative analysis, segments with high-risk plaque had higher total plaque volume, low CT attenuation plaque volume, plaque burden and remodeling index. Quantitatively assessed low CT attenuation plaque volume (odds ratio 1.12 per 1 mm 3 , 95% CI 1.04-1.21), positive remodeling (odds ratio 1.25 per 0.1, 95% CI 1.10-1.41) and plaque burden (odds ratio 1.53 per 0.1, 95% CI 1.08-2.16) were associated with high-risk plaque. Quantitative coronary plaque characteristics (low CT attenuation plaque volume, positive remodeling and plaque burden) measured by semi-automated software correlated with qualitative assessment of high-risk plaque features.

  10. The Incidence and the Risk Factors of Silent Embolic Cerebral Infarction After Coronary Angiography and Percutaneous Coronary Interventions.

    PubMed

    Deveci, Onur Sinan; Celik, Aziz Inan; Ikikardes, Firat; Ozmen, Caglar; Caglıyan, Caglar Emre; Deniz, Ali; Bicakci, Kenan; Bicakci, Sebnem; Evlice, Ahmet; Demir, Turgay; Kanadasi, Mehmet; Demir, Mesut; Demirtas, Mustafa

    2016-05-01

    Silent embolic cerebral infarction (SECI) is a major complication of coronary angiography (CAG) and percutaneous coronary intervention (PCI). Patients with stable coronary artery disease (CAD) who underwent CAG with or without PCI were recruited. Cerebral diffusion-weighted magnetic resonance imaging was performed for SECI within 24 hours. Clinical and angiographic characteristics were compared between patients with and without SECI. Silent embolic cerebral infarction occurred in 12 (12%) of the 101 patients. Age, total cholesterol, SYNTAX score (SS), and coronary artery bypass history were greater in the SECI(+) group (65 ± 10 vs 58 ± 11 years,P= .037; 223 ± 85 vs 173 ± 80 mg/dL,P= .048; 30.1 ± 2 vs 15 ± 3,P< .001; 4 [33.3%] vs 3 [3.3%],P= .005). The SECI was more common in the PCI group (8/24 vs 4/77,P= .01). On subanalysis, the SS was significantly higher in the SECI(+) patients in both the CAG and the PCI groups (29.3 ± 1.9 vs 15 ± 3,P< .01; 30.5 ± 1.9 vs 15.1 ± 3.2,P< .001, respectively). The risk of SECI after CAG and PCI increases with the complexity of CAD (represented by the SS). The SS is a predictor of the risk of SECI, a complication that should be considered more often after CAG. © The Author(s) 2015.

  11. Impacts of coronary artery eccentricity on macro-recirculation and pressure drops using computational fluid dynamics

    NASA Astrophysics Data System (ADS)

    Poon, Eric; Thondapu, Vikas; Barlis, Peter; Ooi, Andrew

    2017-11-01

    Coronary artery disease remains a major cause of mortality in developed countries, and is most often due to a localized flow-limiting stenosis, or narrowing, of coronary arteries. Patients often undergo invasive procedures such as X-ray angiography and fractional flow reserve to diagnose flow-limiting lesions. Even though such diagnostic techniques are well-developed, the effects of diseased coronary segments on local flow are still poorly understood. Therefore, this study investigated the effect of irregular geometries of diseased coronary segments on the macro-recirculation and local pressure minimum regions. We employed an idealized coronary artery model with a diameter of stenosis of 75%. By systematically adjusting the eccentricity and the asymmetry of the coronary stenosis, we uncovered an increase in macro-recirculation size. Most importantly, the presence of this macro-recirculation signifies a local pressure minimum (identified by λ2 vortex identification method). This local pressure minimum has a profound effect on the pressure drops in both longitudinal and planar directions, which has implications for diagnosis and treatment of coronary artery disease. Supported by Australian Research Council LP150100233 and National Computational Infrastructure m45.

  12. Prognostic value of computed tomographic coronary angiography and exercise electrocardiography for cardiovascular events

    PubMed Central

    Kim, Kye-Hwan; Jeon, Kyung Nyeo; Kang, Min Gyu; Ahn, Jong Hwa; Koh, Jin-Sin; Park, Yongwhi; Hwang, Seok-Jae; Jeong, Young-Hoon; Kwak, Choong Hwan; Hwang, Jin-Yong; Park, Jeong Rang

    2016-01-01

    Background/Aims: This study is a head-to-head comparison of predictive values for long-term cardiovascular outcomes between exercise electrocardiography (ex-ECG) and computed tomography coronary angiography (CTCA) in patients with chest pain. Methods: Four hundred and forty-two patients (mean age, 56.1 years; men, 61.3%) who underwent both ex-ECG and CTCA for evaluation of chest pain were included. For ex-ECG parameters, the patients were classified according to negative or positive results, and Duke treadmill score (DTS). Coronary artery calcium score (CACS), presence of plaque, and coronary artery stenosis were evaluated as CTCA parameters. Cardiovascular events for prognostic evaluation were defined as unstable angina, acute myocardial infarction, revascularization, heart failure, and cardiac death. Results: The mean follow-up duration was 2.8 ± 1.1 years. Fifteen patients experienced cardiovascular events. Based on pretest probability, the low- and intermediate-risks of coronary artery disease were 94.6%. Odds ratio of CACS > 40, presence of plaque, coronary stenosis ≥ 50% and DTS ≤ 4 were significant (3.79, p = 0.012; 9.54, p = 0.030; 6.99, p < 0.001; and 4.58, p = 0.008, respectively). In the Cox regression model, coronary stenosis ≥ 50% (hazard ratio, 7.426; 95% confidence interval, 2.685 to 20.525) was only significant. After adding DTS ≤ 4 to coronary stenosis ≥ 50%, the integrated discrimination improvement and net reclassification improvement analyses did not show significant. Conclusions: CTCA was better than ex-ECG in terms of predicting long-term outcomes in low- to intermediate-risk populations. The predictive value of the combination of CTCA and ex-ECG was not superior to that of CTCA alone. PMID:27017387

  13. The role of coronary CT angiography in diagnosis of patent foramen ovale

    PubMed Central

    Kara, Kemal; Sivrioğlu, Ali Kemal; Öztürk, Ersin; İncedayı, Mehmet; Sağlam, Muzaffer; Arıbal, Serkan; Işılak, Zafer; Mutlu, Hakan

    2016-01-01

    PURPOSE We aimed to examine the incidence of patent foramen ovale (PFO) and atrial septal aneurysms (ASA) in the Turkish population using coronary computed tomography angiography (CTA); assess the feasibility of coronary CTA for PFO diagnosis by conducting a comparison with transthoracic echocardiography (TTE); and determine the diagnostic role and characteristics of the interatrial tunnel, free flap valve (FFV), and shunts. METHODS The present study was conducted retrospectively and included a sample of 782 patients. Coronary CTA results for all patients were evaluated for the following parameters: the presence of PFO, the degree of contrast jet (if present due to PFO), ASA existence, free flap valve (FFV) length, and PFO tunnel diameters (1 and 2). Coronary CTA and TTE results for PFO detection were also compared for 19 patients who underwent both procedures. RESULTS PFO was present in 118 patients (15%). In 19 patients who underwent both CTA and TTE, the shunt was present in 15 patients on TTE compared with nine patients on CTA. The sensitivity and specificity of CTA for shunt existence were 53% (8/15) and 75% (3/4), respectively. FFV was observed on CTA in 118 patients (15%). No significant relationship was observed between shunt existence and FFV length (P = 0.148), or between shunt existence and tunnel diameter-1 (P = 0.638) or diameter-2 (P = 0.058). ASAs were present in 16 patients (2%), while accompanying PFO was present in three patients (2.4%). CONCLUSION Coronary CTA constitutes a more practical and efficient alternative to TTE for PFO diagnosis. Further, it allows the clear visualization of anatomical details of the interatrial tunnel, shunts, and associated abnormalities and detects ASAs. PMID:27152642

  14. Contrast media use in patients with chronic kidney disease undergoing coronary angiography: A systematic review and meta-analysis of randomized trials.

    PubMed

    Pandya, Bhavi; Chalhoub, Jean M; Parikh, Valay; Gaddam, Sainath; Spagnola, Jonathan; El-Sayegh, Suzanne; Bogin, Marc; Kandov, Ruben; Lafferty, James; Bangalore, Sripal

    2017-02-01

    Patients with chronic kidney disease (CKD) undergoing coronary angiography (CA), adequate hydration and minimizing volume of contrast media (CM) are class 1b recommendations for preventing contrast induced nephropathy (CIN). Current data are insufficient to justify specific recommendations about isoosmolar vs. low-osmolar contrast media by the ACCF/AHA/SCAI guidelines. Randomized trials comparing IOCM to LOCM in CKD stage 3 and above patients undergoing CA, and reporting incidence of CIN (defined by a rise in creatinine of 25% from baseline) were included in the analysis. The secondary outcome of the study was the incidence of serum creatinine increase by >1mg/dl. A total of 2839 patients were included in 10 trials, in which 1430 patients received IOCM and 1393 received LOCM. When compared to LOCM, IOCM was not associated with significant benefit in preventing CIN (OR=0.72, [CI: 0.50-1.04], P=0.08, I2=59%). Subgroup analysis revealed non-significant difference in incidence of CIN based on baseline use of N-acetylcystine (NAC), diabetes status, ejection fraction, and whether percutaneous coronary intervention vs coronary angiography alone was performed. The difference between IOCM and LOCM was further attenuated when restricted to studies with larger sample size (>250 patients) (OR=0.93; [CI: 0.66-1.30]) or when compared with non-ionic LOCM (OR=0.79, [CI: 0.52-1.21]). In patients with CKD stage 3 and above undergoing coronary angiography, use of IOCM showed overall non-significant difference in incidence of CIN compared to LOCM. The difference was further attenuated when IOCM was compared with non-ionic LOCM. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  15. [Image fusion of gated-SPECT and CT angiography in coronary artery disease. Importance of anatomic-functional correlation].

    PubMed

    Nazarena Pizzi, M; Aguadé Bruix, S; Cuéllar Calabria, H; Aliaga, V; Candell Riera, J

    2010-01-01

    A 77-year old patient was admitted for acute coronary syndrome without ST elevation. His risk was stratified using the myocardial perfusion gated SPECT, mild inferior ischemia being observed. Thus, medical therapy was optimized and the patient was discharged. He continued with exertional dyspnea so a coronary CT angiography was performed. It revealed severe lesions in the proximal RCA. SPECT-CT fusion images correlated the myocardial perfusion defect with a posterior descending artery from the RCA, in a co-dominant coronary area. Subsequently, cardiac catheterism was indicated for his treatment. The current use of image fusion studies is limited to patients in whom it is difficult to attribute a perfusion defect to a specific coronary artery. In our patient, the fusion images helped to distinguish between the RCA and the circumflex artery as the culprit artery of ischemia. Copyright © 2010 Elsevier España, S.L. y SEMNIM. All rights reserved.

  16. X-ray fluorescence camera for imaging of iodine media in vivo.

    PubMed

    Matsukiyo, Hiroshi; Watanabe, Manabu; Sato, Eiichi; Osawa, Akihiro; Enomoto, Toshiyuki; Nagao, Jiro; Abderyim, Purkhet; Aizawa, Katsuo; Tanaka, Etsuro; Mori, Hidezo; Kawai, Toshiaki; Ehara, Shigeru; Sato, Shigehiro; Ogawa, Akira; Onagawa, Jun

    2009-01-01

    X-ray fluorescence (XRF) analysis is useful for measuring density distributions of contrast media in vivo. An XRF camera was developed for carrying out mapping for iodine-based contrast media used in medical angiography. Objects are exposed by an X-ray beam from a cerium target. Cerium K-series X-rays are absorbed effectively by iodine media in objects, and iodine fluorescence is produced from the objects. Next, iodine Kalpha fluorescence is selected out by use of a 58-microm-thick stannum filter and is detected by a cadmium telluride (CdTe) detector. The Kalpha rays are discriminated out by a multichannel analyzer, and the number of photons is counted by a counter card. The objects are moved and scanned by an x-y stage in conjunction with a two-stage controller, and X-ray images obtained by iodine mapping are shown on a personal computer monitor. The scan pitch of the x and y axes was 2.5 mm, and the photon counting time per mapping point was 2.0 s. We carried out iodine mapping of non-living animals (phantoms), and iodine Kalpha fluorescence was produced from weakly remaining iodine elements in a rabbit skin cancer.

  17. Socioeconomic inequalities in health-related quality of life between men and women, 5 years after a coronary angiography.

    PubMed

    Tchicaya, Anastase; Lorentz, Nathalie

    2016-12-03

    The aim of this study is to measure gender differences in health-related quality of life (HRQOL) among men and women patients with cardiovascular diseases (CVD), and to assess the impact of socioeconomic factors on HRQOL between men and women, 5 years after a coronary angiography. The study included 1,289 out of 4,391 patients who had undergone an angiography in the National Institute for Cardiac Surgery and Interventional Cardiology, Luxembourg in 2008/2009. Four indicators of the WHOQOL-BREF questionnaire (Self-rated health, Quality of life, Physical health, and Psychological health) were used in this study as interest variables. To assess the socioeconomic inequalities in HRQOL between men and women, general linear models were constructed for every indicator, with educational level and living conditions as predictors, and demographic variables, cardiovascular risk factors, and cardiovascular events as covariates. Women were older than men (71.5 versus 68.1, p <0.0001) and less likely to be married. HRQOL was significantly different between men and women despite the fact they had the same socioeconomic status. The average score for overall health was 3.7/5 for men versus 3.5/5 for women; similarly, the life quality score was 3.8/5 for men versus 3.6/5 for women. Education level and living conditions were associated with lower HRQOL scores in men and women. The findings showed that women have lower HRQOL than men regarding self-rated health, quality of life, and the WHOQOL-BREF physical and psychological domains 5 years after a coronary angiography. Socioeconomic inequalities affect HRQOL, and their influence was similar in both men and women. Socioeconomic inequalities in HRQOL in women and men with CVD are strong 5 years after a coronary angiography. Taking into account differences in gender and socioeconomic status in intervention strategies to substantially reduce the differences observed between women and men could help improve the effectiveness of

  18. Impact of a New Adaptive Statistical Iterative Reconstruction (ASIR)-V Algorithm on Image Quality in Coronary Computed Tomography Angiography.

    PubMed

    Pontone, Gianluca; Muscogiuri, Giuseppe; Andreini, Daniele; Guaricci, Andrea I; Guglielmo, Marco; Baggiano, Andrea; Fazzari, Fabio; Mushtaq, Saima; Conte, Edoardo; Annoni, Andrea; Formenti, Alberto; Mancini, Elisabetta; Verdecchia, Massimo; Campari, Alessandro; Martini, Chiara; Gatti, Marco; Fusini, Laura; Bonfanti, Lorenzo; Consiglio, Elisa; Rabbat, Mark G; Bartorelli, Antonio L; Pepi, Mauro

    2018-03-27

    A new postprocessing algorithm named adaptive statistical iterative reconstruction (ASIR)-V has been recently introduced. The aim of this article was to analyze the impact of ASIR-V algorithm on signal, noise, and image quality of coronary computed tomography angiography. Fifty consecutive patients underwent clinically indicated coronary computed tomography angiography (Revolution CT; GE Healthcare, Milwaukee, WI). Images were reconstructed using filtered back projection and ASIR-V 0%, and a combination of filtered back projection and ASIR-V 20%-80% and ASIR-V 100%. Image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were calculated for left main coronary artery (LM), left anterior descending artery (LAD), left circumflex artery (LCX), and right coronary artery (RCA) and were compared between the different postprocessing algorithms used. Similarly a four-point Likert image quality score of coronary segments was graded for each dataset and compared. A cutoff value of P < .05 was considered statistically significant. Compared to ASIR-V 0%, ASIR-V 100% demonstrated a significant reduction of image noise in all coronaries (P < .01). Compared to ASIR-V 0%, SNR was significantly higher with ASIR-V 60% in LM (P < .01), LAD (P < .05), LCX (P < .05), and RCA (P < .01). Compared to ASIR-V 0%, CNR for ASIR-V ≥60% was significantly improved in LM (P < .01), LAD (P < .05), and RCA (P < .01), whereas LCX demonstrated a significant improvement with ASIR-V ≥80%. ASIR-V 60% had significantly better Likert image quality scores compared to ASIR-V 0% in segment-, vessel-, and patient-based analyses (P < .01). Reconstruction with ASIR-V 60% provides the optimal balance between image noise, SNR, CNR, and image quality. Copyright © 2018 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  19. Influence of Adaptive Statistical Iterative Reconstruction on coronary plaque analysis in coronary computed tomography angiography.

    PubMed

    Precht, Helle; Kitslaar, Pieter H; Broersen, Alexander; Dijkstra, Jouke; Gerke, Oke; Thygesen, Jesper; Egstrup, Kenneth; Lambrechtsen, Jess

    The purpose of this study was to study the effect of iterative reconstruction (IR) software on quantitative plaque measurements in coronary computed tomography angiography (CCTA). Thirty patients with a three clinical risk factors for coronary artery disease (CAD) had one CCTA performed. Images were reconstructed using FBP, 30% and 60% adaptive statistical IR (ASIR). Coronary plaque analysis was performed as per patient and per vessel (LM, LAD, CX and RCA) measurements. Lumen and vessel volumes and plaque burden measurements were based on automatic detected contours in each reconstruction. Lumen and plaque intensity measurements and HU based plaque characterization were based on corrected contours copied to each reconstruction. No significant changes between FBP and 30% ASIR were found except for lumen- (-2.53 HU) and plaque intensities (-1.28 HU). Between FBP and 60% ASIR the change in total volume showed an increase of 0.94%, 4.36% and 2.01% for lumen, plaque and vessel, respectively. The change in total plaque burden between FBP and 60% ASIR was 0.76%. Lumen and plaque intensities decreased between FBP and 60% ASIR with -9.90 HU and -1.97 HU, respectively. The total plaque component volume changes were all small with a maximum change of -1.13% of necrotic core between FBP and 60% ASIR. Quantitative plaque measurements only showed modest differences between FBP and the 60% ASIR level. Differences were increased lumen-, vessel- and plaque volumes, decreased lumen- and plaque intensities and a small percentage change in the individual plaque component volumes. Copyright © 2016 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

  20. Electrocardiogram‐gated coronary CT angiography dose estimates using ImPACT

    PubMed Central

    Asada, Yasuki; Matsubara, Kosuke; Suzuki, Shouichi; Koshida, Kichiro; Matsunaga, Yuta; Haba, Tomonobu; Kawaguchi, Ai; Toyama, Hiroshi; Kato, Ryoichi

    2016-01-01

    The primary study objective was to assess radiation doses using a modified form of the Imaging Performance Assessment of Computed Tomography (CT) scanner (ImPACT) patient dosimetry for cardiac applications on an Aquilion ONE ViSION Edition scanner, including the Ca score, target computed tomography angiography (CTA), prospective CTA, continuous CTA/cardiac function analysis (CFA), and CTA/CFA modulation. Accordingly, we clarified the CT dose index (CTDI) to determine the relationship between heart rate (HR) and X‐ray exposure. As a secondary objective, we compared radiation doses using modified ImPACT, a whole‐body dosimetry phantom study, and the k‐factor method to verify the validity of the dose results obtained with modified ImPACT. The effective dose determined for the reference person (4.66 mSv at 60 beats per minute (bpm) and 33.43 mSv at 90 bpm) were approximately 10% less than those determined for the phantom study (5.28 mSv and 36.68 mSv). The effective doses according to the k‐factor (0.014 mSv·mGy−1·cm−1; 2.57 mSv and 17.10 mSv) were significantly lower than those obtained with the other two methods. In the present study, we have shown that ImPACT, when modified for cardiac applications, can assess both absorbed and effective doses. The results of our dose comparison indicate that modified ImPACT dose assessment is a promising and practical method for evaluating coronary CTA. PACS number(s): 87.57.Q‐, 87.59.Dj, 87.57.uq PMID:27455500

  1. Breast surface radiation dose during coronary CT angiography: reduction by breast displacement and lead shielding.

    PubMed

    Foley, Shane J; McEntee, Mark F; Achenbach, Stephan; Brennan, Patrick C; Rainford, Louise S; Dodd, Jonathan D

    2011-08-01

    The purpose of this study was to prospectively evaluate the effect of cranial breast displacement and lead shielding on in vivo breast surface radiation dose in women undergoing coronary CT angiography. Fifty-four women (mean age, 59.2 ± 9.8 years) prospectively underwent coronary 64-MDCT angiography for evaluation of chest pain. The patients were randomly assigned to a control group (n = 16), breast displacement group (n = 22), or breast displacement plus lead shielding group (n = 16). Thermoluminescent dosimeters (TLDs) were placed superficially on each breast quadrant and the areolar region of both breasts. Breast surface radiation doses, the degree of breast displacement, and coronary image quality were compared between groups. A phantom dose study was conducted to compare breast doses with z-axis positioning on the chest wall. A total of 1620 TLD dose measurements were recorded. Compared with control values, the mean breast surface dose was reduced 23% in the breast displacement group (24.3 vs 18.6 mGy, p = 0.015) and 36% in the displacement plus lead shielding group (24.3 vs 15.6 mGy, p = 0.0001). Surface dose reductions were greatest in the upper outer (displacement alone, 66%; displacement plus shielding, 63%), upper inner (65%, 58%), and areolar quadrants (44%, 53%). The smallest surface dose reductions were recorded for A-cup breasts: 7% for the displacement group and 3% for the displacement plus lead group (p = 0.741). Larger reductions in surface dose were recorded for B-cup (25% and 56%, p = 0.273), C-cup (38% and 60%, p = 0.001), and D-cup (31% and 25%, p = 0.095) sizes. Most of the patients (79%) had either good (< 50% of breast above scan range) or excellent (< 75% of breast above the scan range) breast displacement. No significant difference in coronary image quality was detected between groups. The phantom dose study showed that surface TLD measurements were underestimates of absorbed tissue dose by a mean of 9% and that a strong negative

  2. Liquid metal angiography for mega contrast X-ray visualization of vascular network in reconstructing in-vitro organ anatomy.

    PubMed

    Wang, Qian; Yu, Yang; Pan, Keqin; Liu, Jing

    2014-07-01

    Visualization on the anatomical vessel networks plays a vital role in the physiological or pathological investigations. However, so far it still remains a big challenge to identify the fine structures of the smallest capillary vessel networks via conventional imaging ways. Here, the room temperature liquid metal angiography was proposed for the first time to generate mega contrast X-ray images for multiscale vasculature mapping. Particularly, gallium was adopted as the room temperature liquid metal contrast agent and infused into the vessels of in vitro pig hearts and kidneys. We scanned the samples under X-ray and compared the angiograms with those obtained via conventional contrast agent--the iohexol. As quantitatively demonstrated by the grayscale histograms and numerical indexes, the contrast of the vessels to the surrounding tissues in the liquid metal angiograms is orders higher than that of the iohexol enhanced images. And the angiogram has reached detailed enough width of 0.1 mm for the tiny vessels, which indicated that the capillaries can be clearly distinguished under the liquid metal enhanced images. Further, with tomography from the micro-CT, we also managed to reconstruct the 3-D structures of the kidney vessels. Tremendous clarity and efficiency of the method over existing approaches have been experimentally clarified. It was disclosed that the usually invisible capillary networks now become distinctively clear in the gallium angiograms. This basic mechanism has generalized purpose and can be extended to a wide spectrum of 3-D computational tomographic areas. It opens a new soft tool for quickly reconstructing high-resolution spatial channel networks for scientific researches as well as engineering practices where complicated and time-consuming resections are no longer a necessity.

  3. A LabVIEW Platform for Preclinical Imaging Using Digital Subtraction Angiography and Micro-CT.

    PubMed

    Badea, Cristian T; Hedlund, Laurence W; Johnson, G Allan

    2013-01-01

    CT and digital subtraction angiography (DSA) are ubiquitous in the clinic. Their preclinical equivalents are valuable imaging methods for studying disease models and treatment. We have developed a dual source/detector X-ray imaging system that we have used for both micro-CT and DSA studies in rodents. The control of such a complex imaging system requires substantial software development for which we use the graphical language LabVIEW (National Instruments, Austin, TX, USA). This paper focuses on a LabVIEW platform that we have developed to enable anatomical and functional imaging with micro-CT and DSA. Our LabVIEW applications integrate and control all the elements of our system including a dual source/detector X-ray system, a mechanical ventilator, a physiological monitor, and a power microinjector for the vascular delivery of X-ray contrast agents. Various applications allow cardiac- and respiratory-gated acquisitions for both DSA and micro-CT studies. Our results illustrate the application of DSA for cardiopulmonary studies and vascular imaging of the liver and coronary arteries. We also show how DSA can be used for functional imaging of the kidney. Finally, the power of 4D micro-CT imaging using both prospective and retrospective gating is shown for cardiac imaging.

  4. A LabVIEW Platform for Preclinical Imaging Using Digital Subtraction Angiography and Micro-CT

    PubMed Central

    Badea, Cristian T.; Hedlund, Laurence W.; Johnson, G. Allan

    2013-01-01

    CT and digital subtraction angiography (DSA) are ubiquitous in the clinic. Their preclinical equivalents are valuable imaging methods for studying disease models and treatment. We have developed a dual source/detector X-ray imaging system that we have used for both micro-CT and DSA studies in rodents. The control of such a complex imaging system requires substantial software development for which we use the graphical language LabVIEW (National Instruments, Austin, TX, USA). This paper focuses on a LabVIEW platform that we have developed to enable anatomical and functional imaging with micro-CT and DSA. Our LabVIEW applications integrate and control all the elements of our system including a dual source/detector X-ray system, a mechanical ventilator, a physiological monitor, and a power microinjector for the vascular delivery of X-ray contrast agents. Various applications allow cardiac- and respiratory-gated acquisitions for both DSA and micro-CT studies. Our results illustrate the application of DSA for cardiopulmonary studies and vascular imaging of the liver and coronary arteries. We also show how DSA can be used for functional imaging of the kidney. Finally, the power of 4D micro-CT imaging using both prospective and retrospective gating is shown for cardiac imaging. PMID:27006920

  5. Long-Term Prognostic Value of Coronary CT Angiography in Asymptomatic Type 2 Diabetes Mellitus.

    PubMed

    Kang, Se Hun; Park, Gyung-Min; Lee, Seung-Whan; Yun, Sung-Cheol; Kim, Young-Hak; Cho, Young-Rak; Park, Hyun Woo; Suh, Jon; Yang, Dong Hyun; Kang, Joon-Won; Lim, Tae-Hwan; Jung, Chang Hee; Koh, Eun Hee; Lee, Woo Je; Kim, Min-Seon; Lee, Ki-Up; Park, Joong-Yeol

    2016-11-01

    This study sought to evaluate the long-term prognostic value of coronary computed tomography angiography (CTA) in asymptomatic patients with type 2 diabetes mellitus. There are limited data on the long-term prognostic impact of coronary CTA in asymptomatic patients with type 2 diabetes mellitus. This study analyzed clinical outcomes of 591 consecutive asymptomatic patients with type 2 diabetes mellitus who underwent coronary CTA (mean age 62.2 ± 8.3 years and 352 men [59.6%]). A cardiac event was defined as a composite of cardiac death, nonfatal myocardial infarction, unstable angina requiring hospitalization, or late coronary revascularization. Patients were categorized into 3 groups according to severity of coronary artery disease (CAD) on coronary CTA: normal coronary arteries, nonobstructive CAD (<50%), and obstructive CAD (≥50%). One hundred sixty-eight patients (28.4%) had normal coronary arteries, whereas 236 (39.9%) patients had nonobstructive CAD and 187 (31.6%) had obstructive CAD. During the follow-up period (median 5.3 years [interquartile range: 4.7 to 5.8 years]), 37 cardiac events occurred in 29 patents: 10 cardiac deaths, 2 nonfatal myocardial infarctions, 8 cases of unstable angina, and 17 late coronary revascularizations. The 6-year event-free survival rates were 99.3 ± 0.7% in patients with normal coronary arteries, 96.7 ± 1.2% in patients with nonobstructive CAD, and 86.2 ± 3.0% in patients with obstructive CAD (log-rank p < 0.001). Asymptomatic patients with type 2 diabetes mellitus with normal coronary arteries or nonobstructive CAD on coronary CTA show excellent clinical outcomes over a follow-up period of more than 5 years, whereas prognosis is worse in patients with obstructive CAD. These findings suggest long-term prognostic value of coronary CTA for asymptomatic type 2 diabetes mellitus. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  6. Coronary angiography and myocardial revascularization following the first acute myocardial infarction in Norway during 2001-2009: Analyzing time trends and educational inequalities using data from the CVDNOR project.

    PubMed

    Sulo, Enxhela; Nygård, Ottar; Vollset, Stein Emil; Igland, Jannicke; Sulo, Gerhard; Ebbing, Marta; Egeland, Grace M; Hawkins, Nathaniel M; Tell, Grethe S

    2016-06-01

    We analyzed trends in the utilization of coronary angiography and revascularization - including percutaneous coronary intervention (PCI) or coronary artery bypass surgery (CABG) - related to the first AMI and explored potential educational inequalities in such procedures. All first AMI patients aged 35-89, hospitalized during 2001-2009 were retrieved from 'The Cardiovascular Disease in Norway' project. Information on education was obtained from The Norwegian Education Database. Gender and age group-specific trends in coronary procedures were analyzed using Joinpoint regression. Educational inequalities were explored using multivariable Poisson regression and reported as incidence rate ratios (IRR). A total of 104 836 patients (37.3% women) were included. Revascularization rates increased on average 9.0% and 15.4% per year among younger (35-64years) and older (65-89years) men. Corresponding increases among women were 5.6% and 16.6%. Compared to patients with primary education only, those with secondary and tertiary education had 8% (IRR=1.08, 95% CI; 1.06-1.10) and 12% (IRR=1.12, 95% CI; 1.09-1.14) higher revascularization rates. Educational inequalities were entirely driven by educational differences in receiving coronary angiography (IRR=1.10, 95% CI; 1.08-1.11 for secondary versus primary and IRR=1.14, 95% CI; 1.12-1.16 for tertiary versus primary education level.) Among diagnosed patients, no educational differences were observed in coronary revascularization rates. Revascularization rates increased whereas educational differences in revascularization decreased among AMI patients in Norway during 2001-2009. Lower coronary revascularization rates among patients with low education were explained by educational differences in receiving coronary angiography. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  7. [Examination of patient dose reduction in cardiovasucular X-ray systems with a metal filter].

    PubMed

    Yasuda, Mitsuyoshi; Kato, Kyouichi; Tanabe, Nobuaki; Sakiyama, Koushi; Uchiyama, Yushi; Suzuki, Yoshiaki; Suzuki, Hiroshi; Nakazawa, Yasuo

    2012-01-01

    In interventional X-ray for cardiology of flat panel digital detector (FPD), the phenomenon that exposure dose was suddenly increased when a subject thickness was thickened was recognized. At that time, variable metal built-in filters in FPD were all off. Therefore, we examined whether dose reduction was possible without affecting a clinical image using metal filter (filter) which we have been conventionally using for dose reduction. About 45% dose reduction was achieved when we measured an exposure dose at 30 cm of acrylic thickness in the presence of a filter. In addition, we measured signal to noise ratio/contrast to noise ratio/a resolution limit by the visual evaluation, and there was no influence by filter usage. In the clinical examination, visual evaluation of image quality of coronary angiography (40 cases) using a 5-point evaluation scale by a physician was performed. As a result, filter usage did not influence the image quality (p=NS). Therefore, reduction of sudden increase of exposure dose was achieved without influencing an image quality by adding filter to FPD.

  8. Benefit of immediate coronary angiography after out-of-hospital cardiac arrest in France: A nationwide propensity score analysis from the RéAC Registry.

    PubMed

    Jaeger, Déborah; Dumas, Florence; Escutnaire, Josephine; Sadoune, Sonia; Lauvray, Adrien; Elkhoury, Carlos; Bassand, Adrien; Girerd, Nicolas; Gueugniaud, Pierre Yves; Tazarourte, Karim; Hubert, Hervé; Cariou, Alain; Chouihed, Tahar

    2018-05-01

    The survival rate of out-of-hospital cardiac arrest (OHCA) remains extremely low, generally under 10%. Post-resuscitation care, and particularly early coronary reperfusion, may improve this outcome. The main objective of the present study was to determine whether patients with immediate coronary angiography at hospital admission (CAA) had a better outcome than patients without immediate CAA. This cohort analysis study was based on data extracted from the French National Cardiac Arrest registry (RéAC). To control for attribution bias, patients were matched using a propensity score, which included age clusters, low flow and no flow delays, initial rhythm and bystander cardiopulmonary resuscitation (CPR). The main endpoint was survival at day 30 (D30). Secondary endpoint was neurological recovery of survivors assessed by the Cerebral Performance Category (CPC) scale, with CPC 1 and 2 at D30 considered as a favorable outcome. From July 1st, 2011 to October 1st, 2016, 63394 OHCA were registered in the database, of which 39444 were of an unknown or suspected cardiac origin. After on-site resuscitation by a mobile medical team, 7584 patients were transported to a hospital facility. Among these patients, 4046 were retained in the analysis after matching for the aforementioned factors and constituted into 2 groups: immediate coronary angiography (iCAA) group (n = 2023) and non-immediate coronary angiography (niCAA) group (n = 2023). The survival rate at D30 after matching was 43.3% in the iCAA group versus 34.5% in the niCAA group (OD = 0.66 [0.58; 0.75], p < 0.001). In the iCAA group, (n = 707) 36% of the patients at D30 were CPC 1-2 comparatively to (n = 539) 27.3% in the niCAA group (p < 0.01). Both the survival and proportion of patients with favorable neurological recovery were significantly higher in patients who underwent an immediate coronary angiography after a resuscitated OHCA. These observational results warrant further exploration

  9. SYNTAX score based on coronary computed tomography angiography may have a prognostic value in patients with complex coronary artery disease: An observational study from a retrospective cohort.

    PubMed

    Suh, Young Joo; Han, Kyunghwa; Chang, Suyon; Kim, Jin Young; Im, Dong Jin; Hong, Yoo Jin; Lee, Hye-Jeong; Hur, Jin; Kim, Young Jin; Choi, Byoung Wook

    2017-09-01

    The SYNergy between percutaneous coronary intervention with TAXus and cardiac surgery (SYNTAX) score is an invasive coronary angiography (ICA)-based score for quantifying the complexity of coronary artery disease (CAD). Although the SYNTAX score was originally developed based on ICA, recent publications have reported that coronary computed tomography angiography (CCTA) is a feasible modality for the estimation of the SYNTAX score.The aim of our study was to investigate the prognostic value of the SYNTAX score, based on CCTA for the prediction of major adverse cardiac and cerebrovascular events (MACCEs) in patients with complex CAD.The current study was approved by the institutional review board of our institution, and informed consent was waived for this retrospective cohort study. We included 251 patients (173 men, mean age 66.0 ± 9.29 years) who had complex CAD [3-vessel disease or left main (LM) disease] on CCTA. SYNTAX score was obtained on the basis of CCTA. Follow-up clinical outcome data regarding composite MACCEs were also obtained. Cox proportional hazards models were developed to predict the risk of MACCEs based on clinical variables, treatment, and computed tomography (CT)-SYNTAX scores.During the median follow-up period of 1517 days, there were 48 MACCEs. Univariate Cox hazards models demonstrated that MACCEs were associated with advanced age, low body mass index (BMI), and dyslipidemia (P < .2). In patients with LM disease, MACCEs were associated with a higher SYNTAX score. In patients with CT-SYNTAX score ≥23, patients who underwent coronary artery bypass graft surgery (CABG) and percutaneous coronary intervention had significantly lower hazard ratios than patients who were treated with medication alone. In multivariate Cox hazards model, advanced age, low BMI, and higher SYNTAX score showed an increased hazard ratio for MACCE, while treatment with CABG showed a lower hazard ratio (P < .2).On the basis of our results, CT-SYNTAX score

  10. CT coronary angiography and exercise ECG in a population with chest pain and low-to-intermediate pre-test likelihood of coronary artery disease.

    PubMed

    Maffei, Erica; Seitun, Sara; Martini, Chiara; Palumbo, Alessandro; Tarantini, Giuseppe; Berti, Elena; Grilli, Roberto; Tedeschi, Carlo; Messalli, Giancarlo; Guaricci, Andrea; Weustink, Annick C; Mollet, Nico Ra; Cademartiri, Filippo

    2010-12-01

    To evaluate diagnostic accuracy of exercise ECG (ex-ECG) versus 64-slice CT coronary angiography (CT-CA) for the detection of significant coronary artery stenosis in a population with low-to-intermediate pre-test likelihood of coronary artery disease (CAD). Retrospective single centre. Tertiary academic hospital. 177 consecutive patients (88 men, 89 women, mean age 53.5±7.6 years) with chest pain and low-to-intermediate pre-test likelihood of CAD were retrospectively enrolled. All patients underwent ex-ECG, CT-CA and invasive coronary angiography (ICA). A lumen diameter reduction of ≥50% was considered as significant stenosis for CT-CA. Ex-ECG was classified as positive, negative or non-diagnostic. were compared with ICA. Diagnostic accuracy of CT-CA and ex-ECG was calculated using ICA as the reference standard. A parallel comparative analysis using a cut-off value of 70% for significant lumen reduction was also performed too. Results ICA disclosed an absence of significant stenosis (≥50% luminal narrowing) in 85.3% (151/177) patients, single-vessel disease in 9.0% (16/177) patients and multivessel disease in 5.6% (10/177) patients. Prevalence of obstructive disease at ICA was 14.7% (26/177). Sensitivity, specificity, positive and negative predictive values at the patient level were 100.0%, 98.7%, 92.9%, 100%, respectively, for CT-CA and 46.2%, 16.6%, 8.7%, 64.1%, respectively, for ex-ECG. Agreement between CT-CA and ex-ECG was 20.9%. CT-CA performed equally well in men and women, while ex-ECG had a better performance in men. After considering the cut-off value of 70% for significant stenosis, the difference between CT-CA and ex-ECG remained significant (p<0.01), with a low agreement (21.5%). CT-CA provides optimal diagnostic performance in patients with atypical chest pain and low-to-intermediate risk of CAD. Ex-ECG has poor diagnostic accuracy in this population. Concerns are related to risk of radiation dose versus the benefits of correct disease

  11. Lumen and calcium characteristics within calcified coronary lesions. Comparison of computed tomography coronary angiography versus intravascular ultrasound.

    PubMed

    Noll, Dariusz; Kruk, Mariusz; Pręgowski, Jerzy; Kaczmarska, Edyta; Kryczka, Karolina; Pracoń, Radosław; Skwarek, Mirosław; Dzielińska, Zofia; Petryka, Joanna; Spiewak, Mateusz; Lubiszewska, Barbara; Norwa-Otto, Bożena; Opolski, Maksymilian; Witkowski, Adam; Demkow, Marcin; Rużyłło, Witold; Kępka, Cezary

    2013-01-01

    Computed tomography coronary angiography (CTCA) is a diagnostic method used for exclusion of coronary artery disease. However, lower accuracy of CTCA in assessment of calcified lesions is a significant factor impeding applicability of CTCA for assessment of coronary atherosclerosis. To provide insight into lumen and calcium characteristics assessed with CTCA, we compared these parameters to the reference of intravascular ultrasound (IVUS). Two hundred and fifty-two calcified lesions within 97 arteries of 60 patients (19 women, age 63 ±10 years) underwent assessment with both 2 × 64 slice CT (Somatom Definition, Siemens) and IVUS (s5, Volcano Corp.). Coronary lumen and calcium dimensions within calcified lesions were assessed with CTCA and compared to the reference measurements made with IVUS. On average CTCA underestimated mean lumen diameter (2.8 ±0.7 mm vs. 2.9 ±0.8 mm for IVUS), lumen area (6.4 ±3.4 mm(2) vs. 7.0 ±3.7 mm(2) for IVUS, p < 0.001) and total calcium arc (52 ±35° vs. 83 ±54°). However, analysis of tertiles of the examined parameters revealed that the mean lumen diameter, lumen area and calcium arc did not significantly differ between CTCA and IVUS within the smallest lumens (1(st) tertile of mean lumen diameter at 2.1 mm, and 1(st) tertile of lumen area at 3.7 mm(2)) and lowest calcium arc (mean of 40°). Although, on average, CTCA underestimates lumen diameter and area as well as calcium arc within calcified lesions, the differences are not significant within the smallest vessels and calcium arcs. The low diagnostic accuracy of CTCA within calcified lesions may be attributed to high variance and not to systematic error of measurements.

  12. Coronary artery to pulmonary artery fistula.

    PubMed

    Dadkhah-Tirani, Heidar; Salari, Arsalan; Shafighnia, Shora; Hosseini, Seyed Fazel; Naghdipoor, Misa

    2013-01-01

    Male, 69 FINAL DIAGNOSIS: Coronary artery to pulmonary artery fistula Symptoms: Chest pain Medication: - Clinical Procedure: Echocardiography • angiography • surgical intervention Specialty: Cardiology • Cardiac Surgery. Rare disease. A coronary artery fistula is an abnormal communication between a coronary artery and one of the cardiac chambers or a great vessel, so bypassing the myocardial capillary network. They are usually discovered incidentally upon coronary angiography. Clinical manifestations are variable depending on the type of fistula, the severity of shunt, site of shunt, and presence of other cardiac condition. We report a 69-year-old man without any previous medical history, who was admitted to our hospital with chest pain. The electrocardiogram (ECG) showed a sinus rhythm with ST depression in V2 to V6 precordial leads. Coronary angiography revealed a coronary artery fistula from left anterior descending coronary artery (LAD) to the main pulmonary artery, right coronary artery blockage and significant stenoses on the LAD and left circumflex artery (LCX). Surgical treatment was chosen because of the total occlusion of the right coronary artery and to relieve of pain to improve quality of life.

  13. Novel Non-invasive Estimation of Coronary Blood Flow using Contrast Advection in Computed Tomography Angiography

    NASA Astrophysics Data System (ADS)

    Eslami, Parastou; Seo, Jung-Hee; Rahsepar, Amirali; George, Richard; Lardo, Albert; Mittal, Rajat

    2014-11-01

    Coronary computed tomography angiography (CTA) is a promising tool for assessment of coronary stenosis and plaque burden. Recent studies have shown the presence of axial contrast concentration gradients in obstructed arteries, but the mechanism responsible for this phenomenon is not well understood. We use computational fluid dynamics to study intracoronary contrast dispersion and the correlation of concentration gradients with intracoronary blood flow and stenotic severity. Data from our CFD patient-specific simulations reveals that contrast dispersions are generated by intracoronary advection effects, and therefore, encode the coronary flow velocity. This novel method- Transluminal Attenuation Flow Encoding (TAFE) - is used to estimate the flowrate in phantom studies as well as preclinical experiments. Our results indicate a strong correlation between the values estimated from TAFE and the values measured in these experiments. The flow physics of contrast dispersion associated with TAFE will be discussed. This work is funded by grants from Coulter Foundation and Maryland Innovation Initiative. The authors have pending patents in this technology and RM and ACL have other financial interests associated with TAFE.

  14. Atherosclerotic Plaque in Patients with Zero Calcium Score at Coronary Computed Tomography Angiography

    PubMed Central

    Gabriel, Fabíola Santos; Gonçalves, Luiz Flávio Galvão; de Melo, Enaldo Vieira; Sousa, Antônio Carlos Sobral; Pinto, Ibraim Masciarelli Francisco; Santana, Sara Melo Macedo; de Matos, Carlos José Oliveira; Souto, Maria Júlia Silveira; Conceição, Flávio Mateus do Sacramento; Oliveira, Joselina Luzia Menezes

    2018-01-01

    Background In view of the high mortality for cardiovascular diseases, it has become necessary to stratify the main risk factors and to choose the correct diagnostic modality. Studies have demonstrated that a zero calcium score (CS) is characteristic of a low risk for cardiovascular events. However, the prevalence of individuals with coronary atherosclerotic plaques and zero CS is conflicting in the specialized literature. Objective To evaluate the frequency of patients with coronary atherosclerotic plaques, their degree of obstruction and associated factors in patients with zero CS and indication for coronary computed tomography angiography (CCTA). Methods This is a cross-sectional, prospective study with 367 volunteers with zero CS at CCTA in four diagnostic imaging centers in the period from 2011 to 2016. A significance level of 5% and 95% confidence interval were adopted. Results The frequency of atherosclerotic plaque in the coronary arteries in 367 patients with zero CS was 9.3% (34 individuals). In this subgroup, mean age was 52 ± 10 years, 18 (52.9%) were women and 16 (47%) had significant coronary obstructions (> 50%), with involvement of two or more segments in 4 (25%) patients. The frequency of non-obese individuals (90.6% vs 73.9%, p = 0.037) and alcohol drinkers (55.9% vs 34.8%, p = 0.015) was significantly higher in patients with atherosclerotic plaques, with an odds ratio of 3.4 for each of this variable. Conclusions The frequency of atherosclerotic plaque with zero CS was relatively high, indicating that the absence of calcification does not exclude the presence of plaques, many of which obstructive, especially in non-obese subjects and alcohol drinkers. PMID:29723329

  15. Atherosclerotic Plaque in Patients with Zero Calcium Score at Coronary Computed Tomography Angiography.

    PubMed

    Gabriel, Fabíola Santos; Gonçalves, Luiz Flávio Galvão; Melo, Enaldo Vieira de; Sousa, Antônio Carlos Sobral; Pinto, Ibraim Masciarelli Francisco; Santana, Sara Melo Macedo; Matos, Carlos José Oliveira de; Souto, Maria Júlia Silveira; Conceição, Flávio Mateus do Sacramento; Oliveira, Joselina Luzia Menezes

    2018-05-03

    In view of the high mortality for cardiovascular diseases, it has become necessary to stratify the main risk factors and to choose the correct diagnostic modality. Studies have demonstrated that a zero calcium score (CS) is characteristic of a low risk for cardiovascular events. However, the prevalence of individuals with coronary atherosclerotic plaques and zero CS is conflicting in the specialized literature. To evaluate the frequency of patients with coronary atherosclerotic plaques, their degree of obstruction and associated factors in patients with zero CS and indication for coronary computed tomography angiography (CCTA). This is a cross-sectional, prospective study with 367 volunteers with zero CS at CCTA in four diagnostic imaging centers in the period from 2011 to 2016. A significance level of 5% and 95% confidence interval were adopted. The frequency of atherosclerotic plaque in the coronary arteries in 367 patients with zero CS was 9.3% (34 individuals). In this subgroup, mean age was 52 ± 10 years, 18 (52.9%) were women and 16 (47%) had significant coronary obstructions (> 50%), with involvement of two or more segments in 4 (25%) patients. The frequency of non-obese individuals (90.6% vs 73.9%, p = 0.037) and alcohol drinkers (55.9% vs 34.8%, p = 0.015) was significantly higher in patients with atherosclerotic plaques, with an odds ratio of 3.4 for each of this variable. The frequency of atherosclerotic plaque with zero CS was relatively high, indicating that the absence of calcification does not exclude the presence of plaques, many of which obstructive, especially in non-obese subjects and alcohol drinkers.

  16. Monitoring X-Ray Emission from X-Ray Bursters

    NASA Technical Reports Server (NTRS)

    Halpern, Jules P.; Kaaret, Philip

    1999-01-01

    The scientific goal of this project was to monitor a selected sample of x-ray bursters using data from the All-Sky Monitor (ASM) on the Rossi X-Ray Timing Explorer together with data from the Burst and Transient Source Experiment (BATSE) on the Compton Gamma-Ray Observatory to study the long-term temporal evolution of these sources in the x-ray and hard x-ray bands. The project was closely related to "Long-Term Hard X-Ray Monitoring of X-Ray Bursters", NASA project NAG5-3891, and and "Hard x-ray emission of x-ray bursters", NASA project NAG5-4633, and shares publications in common with both of these. The project involved preparation of software for use in monitoring and then the actual monitoring itself. These efforts have lead to results directly from the ASM data and also from Target of Opportunity Observations (TOO) made with the Rossi X-Ray Timing Explorer based on detection of transient hard x-ray outbursts with the ASM and BATSE.

  17. Detection of X-ray photons by solution-processed organic-inorganic perovskites

    PubMed Central

    Yakunin, Sergii; Sytnyk, Mykhailo; Kriegner, Dominik; Shrestha, Shreetu; Richter, Moses; Matt, Gebhard J.; Azimi, Hamed; Brabec, Christoph J.; Stangl, Julian; Kovalenko, Maksym V.; Heiss, Wolfgang

    2017-01-01

    The evolution of real-time medical diagnostic tools such as angiography and computer tomography from radiography based on photographic plates was enabled by the development of integrated solid-state X-ray photon detectors, based on conventional solid-state semiconductors. Recently, for optoelectronic devices operating in the visible and near infrared spectral regions, solution-processed organic and inorganic semiconductors have also attracted immense attention. Here we demonstrate a possibility to use such inexpensive semiconductors for sensitive detection of X-ray photons by direct photon-to-current conversion. In particular, methylammonium lead iodide perovskite (CH3NH3PbI3) offers a compelling combination of fast photoresponse and a high absorption cross-section for X-rays, owing to the heavy Pb and I atoms. Solution processed photodiodes as well as photoconductors are presented, exhibiting high values of X-ray sensitivity (up to 25 µC mGyair-1 cm-3) and responsivity (1.9×104 carriers/photon), which are commensurate with those obtained by the current solid-state technology. PMID:28553368

  18. Coronary artery analysis: Computer-assisted selection of best-quality segments in multiple-phase coronary CT angiography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhou, Chuan, E-mail: chuan@umich.edu; Chan, Heang-

    Purpose: The authors are developing an automated method to identify the best-quality coronary arterial segment from multiple-phase coronary CT angiography (cCTA) acquisitions, which may be used by either interpreting physicians or computer-aided detection systems to optimally and efficiently utilize the diagnostic information available in multiple-phase cCTA for the detection of coronary artery disease. Methods: After initialization with a manually identified seed point, each coronary artery tree is automatically extracted from multiple cCTA phases using our multiscale coronary artery response enhancement and 3D rolling balloon region growing vessel segmentation and tracking method. The coronary artery trees from multiple phases are thenmore » aligned by a global registration using an affine transformation with quadratic terms and nonlinear simplex optimization, followed by a local registration using a cubic B-spline method with fast localized optimization. The corresponding coronary arteries among the available phases are identified using a recursive coronary segment matching method. Each of the identified vessel segments is transformed by the curved planar reformation (CPR) method. Four features are extracted from each corresponding segment as quality indicators in the original computed tomography volume and the straightened CPR volume, and each quality indicator is used as a voting classifier for the arterial segment. A weighted voting ensemble (WVE) classifier is designed to combine the votes of the four voting classifiers for each corresponding segment. The segment with the highest WVE vote is then selected as the best-quality segment. In this study, the training and test sets consisted of 6 and 20 cCTA cases, respectively, each with 6 phases, containing a total of 156 cCTA volumes and 312 coronary artery trees. An observer preference study was also conducted with one expert cardiothoracic radiologist and four nonradiologist readers to visually rank vessel

  19. [Clinical study on the coronary artery interventions guided by the magnetic navigation system].

    PubMed

    Li, Chun-jian; Wang, Hui; Wang, Lian-sheng; Zhu, Tie-bing; Yang, Zhi-jian; Cao, Ke-jiang

    2010-03-01

    To investigate the efficacy and safety of the magnetic navigation system used in the real world percutaneous coronary artery intervention. All lesions detected by the coronary artery angiography in the magnetic-navigation catheter lab indicated for percutaneous coronary artery intervention (PCI) were included and treated under the guidance of the magnetic navigation system. The characteristics of the target lesion, process of the procedure, time and dosage of the X-ray exposure, and procedure-related complication were recorded and analyzed. One hundred and twenty one patients with 138 lesions were recruited and intervened by PCI during the period from April 2006 to June 2008. Thirty lesions were classified as type A, 50 as type B1, 36 as type B2, 22 as type C (including seven total occlusions). The average stenosis of the target lesions was (85.3 +/- 10.0)%, mean length was (21.1 +/- 10.0) mm. Under the guidance of the magnetic navigation system, 134 target lesions were passed by the magnetic guide-wires, the lesion passing ratio was 97.1%. The X-ray exposure time, X-ray dosage and the contrast volume used during the period of the wire placement were (55.9 +/- 35.4) seconds, (98.0 +/- 86.1) mGy/(490.0 +/- 422.2) microGym(2) and (8.0 +/- 5.4) ml, respectively. A total of 164 stents were implanted in the vessels where the target lesions were passed by the magnetic wires. There was no magnetic navigation system associated complication. Magnetic guide-wires failed to pass four target lesions, two of which were chronic total occlusions (CTOs), and the other two were calcified subtotal occlusions. It is feasible and safe to adopt the magnetic navigation system for the real-world coronary artery intervention. The magnetic guide-wire possesses a high lesion-passing ratio. The CTOs and calcified subtotal occlusions are not ideal lesions for use of the magnetic navigation system.

  20. Nonobstructive Coronary Artery Disease by Coronary CT Angiography Improves Risk Stratification and Allocation of Statin Therapy.

    PubMed

    Emami, Hamed; Takx, Richard A P; Mayrhofer, Thomas; Janjua, Sumbal; Park, Jakob; Pursnani, Amit; Tawakol, Ahmed; Lu, Michael T; Ferencik, Maros; Hoffmann, Udo

    2017-09-01

    This study sought to determine prognostic value of nonobstructive coronary artery disease (CAD) for atherosclerotic cardiovascular disease (ASCVD) events and to determine whether incorporation of this information into the pooled cohort equation reclassifies recommendations for statin therapy as defined by the 2013 guidelines for cholesterol management of the American College of Cardiology and American Heart Association (ACC/AHA). Detection of nonobstructive CAD by coronary computed tomography angiography may improve risk stratification and permit individualized and more appropriate allocation of statin therapy. This study determined the pooled hazard ratio of nonobstructive CAD for ASCVD events from published studies and incorporated this information into the ACC/AHA pooled cohort equation. The study calculated revised sex- and ethnicity-based 10-year ASCVD risk and determined boundaries corresponding to the original 7.5% risk for ASCVD events. It also assessed reclassification for statin eligibility by incorporating the results from meta-analysis to individual patients from a separate cohort. This study included 2 studies (2,295 subjects; 66% male; prevalence of nonobstructive CAD, 47%; median follow-up, 49 months; 67 ASCVD events). The hazard ratio of nonobstructive CAD for ASCVD events was 3.2 (95% confidence interval: 1.5 to 6.7). Incorporation of this information into the pooled cohort equation resulted in reclassification toward statin eligibility in individuals with nonobstructive CAD, with an original ASCVD score of 3.0% and 5.9% or higher in African-American women and men and a score of 4.4% and 4.6% or higher in Caucasian women and men, respectively. The absence of nonobstructive CAD resulted in reclassification toward statin ineligibility if the original ASCVD score was as 10.0% and 17.9% or lower in African-American women and men and 13.7% and 14.3% or lower in Caucasian women and men, respectively. Reclassification is observed in 14% of patients

  1. Fractional Flow Reserve and Coronary Computed Tomographic Angiography: A Review and Critical Analysis.

    PubMed

    Hecht, Harvey S; Narula, Jagat; Fearon, William F

    2016-07-08

    Invasive fractional flow reserve (FFR) is now the gold standard for intervention. Noninvasive functional imaging analyses derived from coronary computed tomographic angiography (CTA) offer alternatives for evaluating lesion-specific ischemia. CT-FFR, CT myocardial perfusion imaging, and transluminal attenuation gradient/corrected contrast opacification have been studied using invasive FFR as the gold standard. CT-FFR has demonstrated significant improvement in specificity and positive predictive value compared with CTA alone for predicting FFR of ≤0.80, as well as decreasing the frequency of nonobstructive invasive coronary angiography. High-risk plaque characteristics have also been strongly implicated in abnormal FFR. Myocardial computed tomographic perfusion is an alternative method with promising results; it involves more radiation and contrast. Transluminal attenuation gradient/corrected contrast opacification is more controversial and may be more related to vessel diameter than stenosis. Important considerations remain: (1) improvement of CTA quality to decrease unevaluable studies, (2) is the diagnostic accuracy of CT-FFR sufficient? (3) can CT-FFR guide intervention without invasive FFR confirmation? (4) what are the long-term outcomes of CT-FFR-guided treatment and how do they compare with other functional imaging-guided paradigms? (5) what degree of stenosis on CTA warrants CT-FFR? (6) how should high-risk plaque be incorporated into treatment decisions? (7) how will CT-FFR influence other functional imaging test utilization, and what will be the effect on the practice of cardiology? (8) will a workstation-based CT-FFR be mandatory? Rapid progress to date suggests that CTA-based lesion-specific ischemia will be the gatekeeper to the cardiac catheterization laboratory and will transform the world of intervention. © 2016 American Heart Association, Inc.

  2. A database for estimating organ dose for coronary angiography and brain perfusion CT scans for arbitrary spectra and angular tube current modulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rupcich, Franco; Badal, Andreu; Kyprianou, Iacovos

    Purpose: The purpose of this study was to develop a database for estimating organ dose in a voxelized patient model for coronary angiography and brain perfusion CT acquisitions with any spectra and angular tube current modulation setting. The database enables organ dose estimation for existing and novel acquisition techniques without requiring Monte Carlo simulations. Methods: The study simulated transport of monoenergetic photons between 5 and 150 keV for 1000 projections over 360 Degree-Sign through anthropomorphic voxelized female chest and head (0 Degree-Sign and 30 Degree-Sign tilt) phantoms and standard head and body CTDI dosimetry cylinders. The simulations resulted in tablesmore » of normalized dose deposition for several radiosensitive organs quantifying the organ dose per emitted photon for each incident photon energy and projection angle for coronary angiography and brain perfusion acquisitions. The values in a table can be multiplied by an incident spectrum and number of photons at each projection angle and then summed across all energies and angles to estimate total organ dose. Scanner-specific organ dose may be approximated by normalizing the database-estimated organ dose by the database-estimated CTDI{sub vol} and multiplying by a physical CTDI{sub vol} measurement. Two examples are provided demonstrating how to use the tables to estimate relative organ dose. In the first, the change in breast and lung dose during coronary angiography CT scans is calculated for reduced kVp, angular tube current modulation, and partial angle scanning protocols relative to a reference protocol. In the second example, the change in dose to the eye lens is calculated for a brain perfusion CT acquisition in which the gantry is tilted 30 Degree-Sign relative to a nontilted scan. Results: Our database provides tables of normalized dose deposition for several radiosensitive organs irradiated during coronary angiography and brain perfusion CT scans. Validation results

  3. Using decision trees for measuring gender equity in the timing of angiography in patients with acute coronary syndrome: a novel approach to equity analysis.

    PubMed

    Bierman, Arlene S; Brown, Adalsteinn D; Levinton, Carey M

    2015-12-23

    Methods to measure or quantify equity in health care remain scarce, if not difficult to interpret. A novel method to measure health equity is presented, applied to gender health equity, and illustrated with an example of timing of angiography in patients following a hospital admission for an acute coronary syndrome. Linked administrative hospital discharge and survey data was used to identify a retrospective cohort of patients hospitalized with Acute Coronary Syndrome (ACS) between 2002 and 2008 who also responded to the Canadian Community Health Survey (CCHS), was analyzed using decision trees to determine whether gender impacted the delay to angiography following an ACS. Defining a delay to angiography as 1 day or more, resulted in a non-significant difference in an equity score of 0.14 for women and 0.12 for men, where 0 and 1 represents perfect equity and inequity respectively. Using 2 and 3 day delays as a secondary outcome resulted in women and men producing scores of 0.19 and 0.17 for a 2 day delay and 0.22 and 0.23 for a 3 day delay. A technique developed expressly for measuring equity suggests that men and women in Ontario receive equitable care in access to angiography with respect to timeliness following an ACS.

  4. New congenital coronary artery anomaly - double supply of single left anterior descending coronary artery from the left and right coronary sinuses: a case report.

    PubMed

    Daralammouri, Yunis; Ghannam, Malik; Lauer, Bernward

    2016-08-02

    A normal anatomy of coronary arteries is important to have adequate cardiac muscle blood supply especially during extraneous physical activities. This case report describes a rare coronary anomaly in which the accessory coronary artery arose from the right coronary artery, reentered the left anterior descending coronary artery, and then ran as a single vessel. We present a case of a coronary anomaly in a 47-year-old white man who presented with atypical angina. Computed tomographic angiography and coronary angiography showed a variant of dual left anterior descending coronary artery not previously described. Our patient's accessory coronary artery arose from his right coronary artery. It took an intramuscular course beneath the right ventricular outflow tract in the interventricular septal area to the anterior interventricular sulcus, giving off septal perforators that reentered his medial left anterior descending coronary artery. Both vessels ran after the anastomosis in the anterior interventricular sulcus as a single vessel. We propose that this anomaly represents a new variant of coronary artery anomaly. This coronary artery anomaly does not cause ischemia. Recognition of this coronary anomaly is important in patients undergoing percutaneous coronary intervention or coronary artery bypass graft operations.

  5. X-ray filter for x-ray powder diffraction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sinsheimer, John Jay; Conley, Raymond P.; Bouet, Nathalie C. D.

    Technologies are described for apparatus, methods and systems effective for filtering. The filters may comprise a first plate. The first plate may include an x-ray absorbing material and walls defining first slits. The first slits may include arc shaped openings through the first plate. The walls of the first plate may be configured to absorb at least some of first x-rays when the first x-rays are incident on the x-ray absorbing material, and to output second x-rays. The filters may comprise a second plate spaced from the first plate. The second plate may include the x-ray absorbing material and wallsmore » defining second slits. The second slits may include arc shaped openings through the second plate. The walls of the second plate may be configured to absorb at least some of second x-rays and to output third x-rays.« less

  6. Prevalence of myocardial bridging detected with 64-slice multidetector coronary computed tomography angiography in asymptomatic adults.

    PubMed

    Atar, Eli; Kornowski, Ran; Fuchs, Shmuell; Naftali, Noa; Belenky, Alexander; Bachar, Gil N

    2007-10-01

    Myocardial bridging is a congenital condition in which a segment of an epicardial artery has an intramural course within the myocardium. The aim of the present study was to evaluate the prevalence of myocardial bridging and the ability of 64-slice coronary computed tomography angiography to identify myocardial bridging in asymptomatic adults. One hundred sixty-nine consecutive asymptomatic subjects underwent 64-row multidetector computed tomography (MDCT) of the coronary arteries. Two experienced CT radiologists identified myocardial bridging >1 mm in thickness, by consensus. We examined the frequency of myocardial bridging and evaluated the length, thickness, and coronary wall lesions. Myocardial bridges were found in 28 (17%) of 165 subjects. Twenty-one subjects (75%) had 1 bridge and 7 subjects (25%) had 2, for a total of 35 myocardial bridges. Twenty-one bridges (60%) were located in the left anterior descending, 8.5% in the diagonal branch, and 2.8% in the circumflex arteries. The segment beneath the myocardial bridge was always free of coronary wall plaques, but the arterial segment proximal to it had significant coronary wall plaques in 24 cases (68.6%). We found that the incidence of myocardial bridging in asymptomatic adults is 7%, which is in agreement with some pathologic studies in the literature. Our study shows that MDCT of the coronary arteries is a reliable and noninvasive technique, which can accurately locate the site of myocardial bridging, and measure its thickness, course, and length.

  7. Combined anatomical and functional imaging using coronary CT angiography and myocardial perfusion SPECT in symptomatic adults with abnormal origin of a coronary artery.

    PubMed

    Uebleis, C; Groebner, M; von Ziegler, F; Becker, A; Rischpler, C; Tegtmeyer, R; Becker, C; Lehner, S; Haug, A R; Cumming, P; Bartenstein, P; Franz, W M; Hacker, M

    2012-10-01

    There has been a lack of standardized workup guidelines for patients with congenital abnormal origin of a coronary artery from the opposite sinus (ACAOS). We aimed to evaluate the use of cardiac hybrid imaging using multi-detector row CT (MDCT) for coronary CT angiography (Coronary CTA) and stress-rest myocardial perfusion SPECT (MPS) for comprehensive diagnosis of symptomatic adult patients with ACAOS. Seventeen symptomatic patients (12 men; 54 ± 13 years) presenting with ACAOS underwent coronary CTA and MPS. Imaging data were analyzed by conventional means, and with additional use of 3D image fusion to allocate stress induced perfusion defects (PD) to their supplying coronary arteries. An anomalous RCA arose from the left anterior sinus in eight patients, an abnormal origin from the right sinus was detected in nine patients (5 left coronary arteries, LCA and 4 LCx). Five of the 17 patients (29%) demonstrated a reversible PD in MPS. There was no correlation between the anatomical variants of ACAOS and the presence of myocardial ischemia. Image fusion enabled the allocation of reversible PD to the anomalous vessel in three patients (two cases in the RCA and the other in the LCA territory); PD in two patients were allocated to the territory of artery giving rise to the anomalies, rather than the anomalies themselves. In a small cohort of adult symptomatic patients with ACAOS anomaly there was no relation found between the specific anatomical variant and the appearance of stress induced myocardial ischemia using cardiac hybrid imaging.

  8. Radiation dose in coronary angiography and intervention: initial results from the establishment of a multi-centre diagnostic reference level in Queensland public hospitals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Crowhurst, James A, E-mail: jimcrowhurst@hotmail.com; School of Medicine, University of Queensland, St. Lucia, Brisbane, Queensland; Whitby, Mark

    Radiation dose to patients undergoing invasive coronary angiography (ICA) is relatively high. Guidelines suggest that a local benchmark or diagnostic reference level (DRL) be established for these procedures. This study sought to create a DRL for ICA procedures in Queensland public hospitals. Data were collected for all Cardiac Catheter Laboratories in Queensland public hospitals. Data were collected for diagnostic coronary angiography (CA) and single-vessel percutaneous intervention (PCI) procedures. Dose area product (P{sub KA}), skin surface entrance dose (K{sub AR}), fluoroscopy time (FT), and patient height and weight were collected for 3 months. The DRL was set from the 75th percentilemore » of the P{sub KA.} 2590 patients were included in the CA group where the median FT was 3.5 min (inter-quartile range = 2.3–6.1). Median K{sub AR} = 581 mGy (374–876). Median P{sub KA} = 3908 uGym{sup 2} (2489–5865) DRL = 5865 uGym{sup 2}. 947 patients were included in the PCI group where median FT was 11.2 min (7.7–17.4). Median K{sub AR} = 1501 mGy (928–2224). Median P{sub KA} = 8736 uGym{sup 2} (5449–12,900) DRL = 12,900 uGym{sup 2}. This study established a benchmark for radiation dose for diagnostic and interventional coronary angiography in Queensland public facilities.« less

  9. Diagnostic accuracy of stress perfusion CMR in comparison with quantitative coronary angiography: fully quantitative, semiquantitative, and qualitative assessment.

    PubMed

    Mordini, Federico E; Haddad, Tariq; Hsu, Li-Yueh; Kellman, Peter; Lowrey, Tracy B; Aletras, Anthony H; Bandettini, W Patricia; Arai, Andrew E

    2014-01-01

    This study's primary objective was to determine the sensitivity, specificity, and accuracy of fully quantitative stress perfusion cardiac magnetic resonance (CMR) versus a reference standard of quantitative coronary angiography. We hypothesized that fully quantitative analysis of stress perfusion CMR would have high diagnostic accuracy for identifying significant coronary artery stenosis and exceed the accuracy of semiquantitative measures of perfusion and qualitative interpretation. Relatively few studies apply fully quantitative CMR perfusion measures to patients with coronary disease and comparisons to semiquantitative and qualitative methods are limited. Dual bolus dipyridamole stress perfusion CMR exams were performed in 67 patients with clinical indications for assessment of myocardial ischemia. Stress perfusion images alone were analyzed with a fully quantitative perfusion (QP) method and 3 semiquantitative methods including contrast enhancement ratio, upslope index, and upslope integral. Comprehensive exams (cine imaging, stress/rest perfusion, late gadolinium enhancement) were analyzed qualitatively with 2 methods including the Duke algorithm and standard clinical interpretation. A 70% or greater stenosis by quantitative coronary angiography was considered abnormal. The optimum diagnostic threshold for QP determined by receiver-operating characteristic curve occurred when endocardial flow decreased to <50% of mean epicardial flow, which yielded a sensitivity of 87% and specificity of 93%. The area under the curve for QP was 92%, which was superior to semiquantitative methods: contrast enhancement ratio: 78%; upslope index: 82%; and upslope integral: 75% (p = 0.011, p = 0.019, p = 0.004 vs. QP, respectively). Area under the curve for QP was also superior to qualitative methods: Duke algorithm: 70%; and clinical interpretation: 78% (p < 0.001 and p < 0.001 vs. QP, respectively). Fully quantitative stress perfusion CMR has high diagnostic accuracy for

  10. Contrast volume to creatinine clearance ratio for the prediction of contrast-induced nephropathy in patients undergoing coronary angiography or percutaneous intervention.

    PubMed

    Barbieri, Lucia; Verdoia, Monica; Marino, Paolo; Suryapranata, Harry; De Luca, Giuseppe

    2016-06-01

    Contrast-induced nephropathy is a common complication of procedures that are likely to use contrast media. The identification of high-risk patients and preventive optimal hydration are key measures to reduce the incidence of contrast-induced nephropathy. The aim of this study was to evaluate the role of the contrast volume to creatinine clearance ratio (V/CrCl) in the prediction of contrast-induced nephropathy after coronary angiography or percutaneous coronary intervention. Our population consisted of 2308 consecutive patients undergoing coronary angiography and/or percutaneous coronary intervention. The risk of contrast-induced nephropathy was evaluated across quartiles of the V/CrCl. Receiver operating characteristic curves were used to identify the best predictive value. Contrast-induced nephropathy was defined as an absolute increase of 0.5 mg/dL or a relative increase of >25% in creatinine levels 24-48 hours after the procedure. The total incidence of contrast-induced nephropathy was 12.2% and was significantly higher in the fourth quartile (first quartile 8.8%, second quartile 8.9%, third quartile 11.6% and fourth quartile 19.4%; P < 0.001). Using receiver operating characteristic curves we identified V/CrCl ≥ 6.15 as the best discriminant value for the prediction of contrast-induced nephropathy, which occurred in 25.1% of patients with V/CrCl ≥ 6.15 versus 9.7% in patients with V/CrCl < 6.15. These results were also confirmed at multivariate analysis after correction for all baseline confounders (adjusted odds ratio (AOR) (95% confidence interval (CI)) 1.81 (1.19-2.76); P = 0.005). The association between V/CrCl > 6.15 and an increased risk of contrast-induced nephropathy was confirmed among diabetic (11% vs. 27.7%; p P < 0.001) and non-diabetic patients (8.9% vs. 23%; Pp < 0.001), also after correction for all baseline confounders. This is one of the largest studies evaluating the association between the V/CrCl ratio

  11. National variation in coronary angiography rates and timing after an acute coronary syndrome in New Zealand (ANZACS-QI 6).

    PubMed

    Williams, Michael J A; Harding, Scott A; Devlin, Gerard; Nunn, Chris; El-Jack, Sief; Scott, Tony; Lee, Mildred; Kerr, Andrew J

    2016-01-08

    The New Zealand Cardiac Clinical Network and the Ministry of Health recommend a "3-day door-to-catheter target" for acute coronary syndromes (ACS) admissions, requiring that at least 70% of ACS patients referred for invasive coronary angiography (ICA) undergo this within 3 days of hospital admission. We assessed the variability in use of ICA, timing of ICA, and duration of hospital admission across New Zealand District Health Boards (DHBs). All patients admitted to all New Zealand public hospitals with suspected ACS undergoing ICA over 1 year ending November 2014 had demographic, risk factor, and diagnostic data collected prospectively using the All New Zealand Acute Coronary Syndrome Quality Improvement (ANZACS-QI) registry. Complete datasets were available in 7,988 (98.4%) patients. DHBs were categorised as those able to perform percutaneous coronary intervention on-site (intervention-capable) or not. There was a near two-fold variation between DHBs in the age standardised rate (ASR) of ICA ranging from 16.8 per 10,000 to 34.1 per 10,000 population (New Zealand rate; 27.9 per 10,000). Patients in intervention-capable DHBs had a 30% higher ASR of ICA. The proportion of ACS patients meeting the 3-day target ranged from 56.7% to 92.9% (New Zealand; 76.4%). Those in intervention-capable DHBs were more likely to meet the target (78.7% vs 68.0%, p<0.0001) and spent 0.84 days (p<.0001) less in hospital. There is a considerable variation in the rate and timing of ICA in New Zealand. Patients with ACS admitted to DHBs without interventional-capability are disadvantaged. New initiatives to correct this discrepancy are needed.

  12. Incidence and predictors of radial artery spasm during transradial coronary angiography and intervention.

    PubMed

    Jia, De-An; Zhou, Yu-Jie; Shi, Dong-Mei; Liu, Yu-Yang; Wang, Jian-Long; Liu, Xiao-Li; Wang, Zhi-Jian; Yang, Shi-Wei; Ge, Hai-Long; Hu, Bin; Yan, Zhen-Xian; Chen, Yi; Gao, Fei

    2010-04-05

    Radial artery spasm (RAS) is the most common complication in transradial coronary angiography and intervention. In this study, we designed to investigate the incidence of RAS during transradial procedures in Chinese, find out the independent predictors through multiple regression, and analyze the clinical effect of RAS during follow-up. Patients arranged to receive transradial coronary angiography and intervention were consecutively enrolled. The incidence of RAS was recorded. Univariate analysis was performed to find out the influence factors of RAS, and logistic regression analysis was performed to find out the independent predictors of RAS. The patients were asked to return 1 month later for the assessment of the radial access. The incidence of RAS was 7.8% (112/1427) in all the patients received transradial procedure. Univariate analysis indicates that young (P = 0.038), female (P = 0.026), small diameter of radial artery (P < 0.001), diabetes (P = 0.026), smoking (P = 0.019), moderate or severe pain during radial artery cannulation (P < 0.001), unsuccessful access at first attempt (P = 0.002), big sheath (P = 0.004), number of catheters (> 3) (P = 0.048), rapid baseline heart rate (P = 0.032) and long operation time (P = 0.021) were associated with RAS. Logistic regression showed that female (OR = 1.745, 95%CI: 1.148 - 3.846, P = 0.024), small radial artery diameter (OR = 4.028, 95%CI: 1.264 - 12.196, P = 0.008), diabetes (OR = 2.148, 95%CI: 1.579 - 7.458, P = 0.019) and unsuccessful access at first attempt (OR = 1.468, 95%CI: 1.212 - 2.591, P = 0.032) were independent predictors of RAS. Follow-up at (28 +/- 7) days after the procedure showed that, compared with non-spasm patients, the RAS patients had higher portion of pain (11.8% vs. 6.2%, P = 0.043). The occurrences of hematoma (7.3% vs. 5.6%, P = 0.518) and radial artery occlusion (3.6% vs. 2.6%, P = 0.534) were similar. The incidence of RAS during transradial coronary procedure was 7.8%. Logistic

  13. The diagnostic accuracy and outcomes after coronary computed tomography angiography vs. conventional functional testing in patients with stable angina pectoris: a systematic review and meta-analysis.

    PubMed

    Nielsen, Lene H; Ortner, Nino; Nørgaard, Bjarne L; Achenbach, Stephan; Leipsic, Jonathon; Abdulla, Jawdat

    2014-09-01

    To systematically review and perform a meta-analysis of the diagnostic accuracy and post-test outcomes of conventional exercise electrocardiography (XECG) and single-photon emission computed tomography (SPECT) compared with coronary computed tomography angiography (coronary CTA) in patients suspected of stable coronary artery disease (CAD). We systematically searched for studies published from January 2002 to February 2013 examining the diagnostic accuracy (defined as at least ≥50% luminal obstruction on invasive coronary angiography) and outcomes of coronary CTA (≥16 slice) in comparison with XECG and SPECT. The search revealed 11 eligible studies (N = 1575) comparing the diagnostic accuracy and 7 studies (N = 216.603) the outcomes of coronary CTA vs. XECG or/and SPECT. The per-patient sensitivity [95% confidence interval (95% CI)] to identify significant CAD was 98% (93-99%) for coronary CTA vs. 67% (54-78%) (P < 0.001) for XECG and 99% (96-100%) vs. 73% (59-83%) (P = 0.001) for SPECT. The specificity (95% CI) of coronary CTA was 82% (63-93%) vs. 46% (30-64%) (P < 0.001) for XECG and 71% (60-80%) vs. 48% (31-64%) (P = 0.14) for SPECT. The odds ratio (OR) of downstream test utilization (DTU) for coronary CTA vs. XECG/SPECT was 1.38 (1.33-1.43, P < 0.001), for revascularization 2.63 (2.50-2.77, P < 0.001), for non-fatal myocardial infarction 0.53 (0.39-0.72, P < 0.001), and for all-cause mortality 1.01 (0.87-1.18, P = 0.87). The up-front diagnostic performance of coronary CTA is higher than of XECG and SPECT. When compared with XECG/SPECT testing, coronary CTA testing is associated with increased DTU and coronary revascularization. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.

  14. Coronary tortuosity: a long and winding road

    PubMed Central

    Zegers, E.S.; Meursing, B.T.J.; Zegers, E.B.; Oude Ophuis, A.J.M.

    2007-01-01

    Coronary tortuosity is a phenomenon often encountered by cardiologists performing coronary angiography. The aetiology and clinical importance of coronary tortuosity are still unclear. Coronary tortuosity without fixed atherosclerotic stenosis in patients with angina pectoris and an abnormal exercise stress test has never been described in the literature. This article describes three cases of patients with anginal complaints, an abnormal exercise stress test and coronary angiography without the presence of a fixed atherosclerotic lesion. It is hypothesised that coronary tortuosity leads to flow alteration resulting in a reduction in coronary pressure distal to the tortuous segment of the coronary artery, subsequently leading to ischaemia. Future studies will be necessary to elucidate the actual mechanism of coronary tortuosity and its clinical significance. (Neth Heart J 2007;15:191-5.17612682) PMID:17612682

  15. Best-Quality Vessel Identification Using Vessel Quality Measure in Multiple-Phase Coronary CT Angiography.

    PubMed

    Hadjiiski, Lubomir; Liu, Jordan; Chan, Heang-Ping; Zhou, Chuan; Wei, Jun; Chughtai, Aamer; Kuriakose, Jean; Agarwal, Prachi; Kazerooni, Ella

    2016-01-01

    The detection of stenotic plaques strongly depends on the quality of the coronary arterial tree imaged with coronary CT angiography (cCTA). However, it is time consuming for the radiologist to select the best-quality vessels from the multiple-phase cCTA for interpretation in clinical practice. We are developing an automated method for selection of the best-quality vessels from coronary arterial trees in multiple-phase cCTA to facilitate radiologist's reading or computerized analysis. Our automated method consists of vessel segmentation, vessel registration, corresponding vessel branch matching, vessel quality measure (VQM) estimation, and automatic selection of best branches based on VQM. For every branch, the VQM was calculated as the average radial gradient. An observer preference study was conducted to visually compare the quality of the selected vessels. 167 corresponding branch pairs were evaluated by two radiologists. The agreement between the first radiologist and the automated selection was 76% with kappa of 0.49. The agreement between the second radiologist and the automated selection was also 76% with kappa of 0.45. The agreement between the two radiologists was 81% with kappa of 0.57. The observer preference study demonstrated the feasibility of the proposed automated method for the selection of the best-quality vessels from multiple cCTA phases.

  16. Adaptive prospective ECG-triggered sequence coronary angiography in dual-source CT without heart rate control: Image quality and diagnostic performance.

    PubMed

    Pan, Chang-Jie; Qian, Nong; Wang, Tao; Tang, Xiao-Qiang; Xue, Yue-Jun

    2013-02-01

    The aim of this study was to evaluate the accuracy of using second generation dual-source CT (DSCT) to obtain high quality images and diagnostic performance and to reduce the radiation dose in adaptive prospective electrocardiography (ECG)-triggered sequence (CorAdSeq) CT coronary angiography (CTCA) without heart rate control. No prescan β-blockers were administered. Un-enhanced CT and CTCA with adaptive prospective CorAdSeq scanning without heart rate control were performed in 683 consecutive patients divided into two body mass index (BMI) groups: BMI <25 kg/m(2) (group A, n=412) and BMI ≥25 kg/m(2) (group B, n=271). The image quality and quantitative stenosis of all coronary segments with a diameter ≥1 mm were assessed. The mean heart rate (MHR), heart rate variability (HRV) and radiation dose values were recorded. In 426 cases, the diagnostic performance was evaluated using quantitative conventional coronary angiography as the reference standard. Diagnostic image quality was obtained in 98.5% of segments in group A and in 98.8% of segments in group B, with no significant differences between the groups. No correlations were observed between the image quality score and MHR or HRV (P=0.492, P=0.564, respectively). The effective radiation doses in groups A and B were 2.57±1.01 mSv and 6.36±1.88 mSv, respectively. The sensitivities and specificities of diagnosing coronary heart disease per patient were 99.6% and 97.8% in group A and 99.5% and 97.5% in group B, respectively (P>0.05). Adaptive prospective CorAdSeq scanning, without heart rate control, by second generation DSCT had a high image quality and diagnostic performance for coronary artery stenosis with lower radiation doses.

  17. Pacemaker-induced Metallic Artifacts in Coronary Computed Tomography Angiography: Clinical Feasibility of Single Energy Metal Artifact Reduction Technique.

    PubMed

    Takayanagi, Tomoya; Arai, Takehiro; Amanuma, Makoto; Sano, Tomonari; Ichiba, Masato; Ishizaka, Kazumasa; Sekine, Takako; Matsutani, Hideyuki; Morita, Hitomi; Takase, Shinichi

    2017-01-01

    Coronary computed tomography angiography (CCTA) in patients with pacemaker suffers from metallic lead-induced artifacts, which often interfere with accurate assessment of coronary luminal stenosis. The purpose of this study was to assess a frequency of the lead-induced artifacts and artifact-suppression effect by the single energy metal artifact reduction (SEMAR) technique. Forty-one patients with a dual-chamber pacemaker were evaluated using a 320 multi-detector row CT (MDCT). Among them, 22 patients with motion-free full data reconstruction images were the final candidates. Images with and without the SMEAR technique were subjectively compared, and the degree of metallic artifacts was compared. On images without SEMAR, severe metallic artifacts were often observed in the right coronary artery (#1, #2, #3) and distal anterior descending branch (#8). These artifacts were effectively suppressed by SEMAR, and the luminal accessibility was significantly improved in #3 and #8. While pacemaker leads often cause metallic-induced artifacts, SEMAR technique reduced the artifacts and significantly improved the accessibility of coronary lumen in #3 and #8.

  18. Incremental diagnostic accuracy of hybrid SPECT/CT coronary angiography in a population with an intermediate to high pre-test likelihood of coronary artery disease.

    PubMed

    Schaap, Jeroen; Kauling, Robert M; Boekholdt, S Matthijs; Nieman, Koen; Meijboom, W Bob; Post, Martijn C; Van der Heyden, Jan A; de Kroon, Thom L; van Es, H Wouter; Rensing, Benno J; Verzijlbergen, J Fred

    2013-07-01

    Hybrid myocardial perfusion imaging with single photon emission computed tomography (SPECT) and CT coronary angiography (CCTA) has the potential to play a major role in patients with non-conclusive SPECT or CCTA results. We evaluated the performance of hybrid SPECT/CCTA vs. standalone SPECT and CCTA for the diagnosis of significant coronary artery disease (CAD) in patients with an intermediate to high pre-test likelihood of CAD. In total, 98 patients (mean age 62.5 ± 10.1 years, 68.4% male) with stable anginal complaints and a median pre-test likelihood of 87% (range 22-95%) were prospectively included in this study. Hybrid SPECT/CCTA was performed prior to conventional coronary angiography (CA) including fractional flow reserve (FFR) measurements. Hybrid analysis was performed by combined interpretation of SPECT and CCTA images. The sensitivity, specificity, positive (PPV), and negative (NPV) predictive values were calculated for standalone SPECT, CCTA, and hybrid SPECT/CCTA on per patient level, using an FFR <0.80 as a reference for significant CAD. Significant CAD was demonstrated in 56 patients (57.9%). Non-conclusive SPECT or CCTA results were found in 32 (32.7%) patients. SPECT had a sensitivity of 93%, specificity 79%, PPV 85%, and NPV 89%. CCTA had a sensitivity of 98%, specificity 62%, PPV 77%, and NPV 96%. Hybrid analysis of SPECT and CCTA improved the overall performance: sensitivity, specificity, PPV, and NPV for the presence of significant CAD to 96, 95, 96, and 95%, respectively. In > 40% of the patients with a high pre-test likelihood no significant CAD was demonstrated, emphasizing the value of accurate pre-treatment cardiovascular imaging. Hybrid SPECT/CCTA was able to accurately diagnose and exclude significant CAD surpassing standalone myocardial SPECT and CCTA, vs. a reference standard of FFR measurements.

  19. Usefulness of Routine Periodic Fasting to Lower Risk of Coronary Artery Disease among Patients Undergoing Coronary Angiography

    PubMed Central

    Horne, Benjamin D.; May, Heidi T.; Anderson, Jeffrey L.; Kfoury, Abdallah G.; Bailey, Beau M.; McClure, Brian S.; Renlund, Dale G.; Lappé, Donald L.; Carlquist, John F.; Fisher, Patrick W.; Pearson, Robert R.; Bair, Tami L.; Adams, Ted D.; Muhlestein, Joseph B.

    2008-01-01

    Coronary artery disease (CAD) is common and multi-factorial. Members of the Church of Jesus Christ of Latter-day Saints (LDS, or Mormons) in Utah may have lower cardiac mortality than other Utahns and the US population. While the LDS proscription of smoking likely contributes to lower cardiac risk, it is unknown whether other shared behaviors also contribute. This study evaluated potential CAD-associated effects of fasting. Patients (N1=4,629) enrolled in the Intermountain Heart Collaborative Study registry (1994-2002) were evaluated for association of religious preference with CAD diagnosis (≥70% coronary stenosis on angiography) or no CAD (normal coronaries, <10% stenosis). Consequently, another set of patients (N2=448) were surveyed (2004-2006) for association of behavioral factors with CAD, with the primary variable being routine fasting (i.e., abstinence from food and drink). Secondary survey measures included proscription of alcohol, tea, and coffee, social support, and religious worship patterns. In population 1 (initial), 61% of LDS and 66% of all others had CAD (adjusted [including for smoking]: odds ratio [OR]=0.81; p=0.009). In population 2 (survey), fasting was associated with lower risk of CAD (64% vs. 76% CAD; OR=0.55, CI=0.35, 0.87; p=0.010) and this remained after adjustment for traditional risk factors (OR=0.46, CI=0.27, 0.81; p=0.007). Fasting was also associated with lower diabetes prevalence (p=0.048). In regression models entering other secondary behavioral measures, fasting remained significant with similar effect size. In conclusion, not only proscription of tobacco, but also routine periodic fasting was associated with lower risk of CAD. PMID:18805103

  20. Submillisievert median radiation dose for coronary angiography with a second-generation 320-detector row CT scanner in 107 consecutive patients.

    PubMed

    Chen, Marcus Y; Shanbhag, Sujata M; Arai, Andrew E

    2013-04-01

    ). Overall, the radiation dose was less than 0.5 mSv for 23 of the 107 CT angiography examinations (21.5%), less than 1 mSv for 58 (54.2%), and less than 4 mSv for 103 (96.3%). All studies were of diagnostic quality, with most having excellent image quality. Three of four image quality indexes were significantly better with the second-generation unit compared with the first-generation unit. The combination of a gantry rotation time of 275 msec, wide volume coverage, iterative reconstruction, automated exposure control, and larger x-ray power generator of the second-generation CT scanner provides excellent image quality over a wide range of body sizes and heart rates at low radiation doses. http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.13122621/-/DC1. RSNA, 2013

  1. Excess Cardiovascular Risk in Women Relative to Men Referred for Coronary Angiography Is Associated With Severely Impaired Coronary Flow Reserve, Not Obstructive Disease.

    PubMed

    Taqueti, Viviany R; Shaw, Leslee J; Cook, Nancy R; Murthy, Venkatesh L; Shah, Nishant R; Foster, Courtney R; Hainer, Jon; Blankstein, Ron; Dorbala, Sharmila; Di Carli, Marcelo F

    2017-02-07

    Cardiovascular disease (CVD) fatality rates are higher for women than for men, yet obstructive coronary artery disease (CAD) is less prevalent in women. Coronary flow reserve (CFR), an integrated measure of large- and small-vessel CAD and myocardial ischemia, identifies patients at risk for CVD death, but is not routinely measured in clinical practice. We sought to investigate the impact of sex, CFR, and angiographic CAD severity on adverse cardiovascular events. Consecutive patients (n=329, 43% women) referred for invasive coronary angiography after stress testing with myocardial perfusion positron emission tomography and with left ventricular ejection fraction >40% were followed (median, 3.0 years) for a composite end point of major adverse cardiovascular events, including cardiovascular death and hospitalization for nonfatal myocardial infarction or heart failure. The extent and severity of angiographic CAD were estimated by using the CAD prognostic index, and CFR was quantified by using positron emission tomography. Although women in comparison with men had lower pretest clinical scores, rates of prior myocardial infarction, and burden of angiographic CAD (P<0.001), they demonstrated greater risk of CVD events, even after adjustment for traditional risk factors, imaging findings, and early revascularization (adjusted hazard ratio, 2.05; 95% confidence interval, 1.05-4.02; P=0.03). Impaired CFR was similarly present among women and men, but in patients with low CFR (<1.6, n=163), women showed a higher frequency of nonobstructive CAD, whereas men showed a higher frequency of severely obstructive CAD (P=0.002). After also adjusting for CFR, the effect of sex on outcomes was no longer significant. When stratified by sex and CFR, only women with severely impaired CFR demonstrated significantly increased adjusted risk of CVD events (P<0.0001, P for interaction=0.04). Women referred for coronary angiography had a significantly lower burden of obstructive CAD in

  2. Diagnostic accuracy of second-generation dual-source computed tomography coronary angiography with iterative reconstructions: a real-world experience.

    PubMed

    Maffei, E; Martini, C; Rossi, A; Mollet, N; Lario, C; Castiglione Morelli, M; Clemente, A; Gentile, G; Arcadi, T; Seitun, S; Catalano, O; Aldrovandi, A; Cademartiri, F

    2012-08-01

    The authors evaluated the diagnostic accuracy of second-generation dual-source (DSCT) computed tomography coronary angiography (CTCA) with iterative reconstructions for detecting obstructive coronary artery disease (CAD). Between June 2010 and February 2011, we enrolled 160 patients (85 men; mean age 61.2±11.6 years) with suspected CAD. All patients underwent CTCA and conventional coronary angiography (CCA). For the CTCA scan (Definition Flash, Siemens), we use prospective tube current modulation and 70-100 ml of iodinated contrast material (Iomeprol 400 mgI/ ml, Bracco). Data sets were reconstructed with iterative reconstruction algorithm (IRIS, Siemens). CTCA and CCA reports were used to evaluate accuracy using the threshold for significant stenosis at ≥50% and ≥70%, respectively. No patient was excluded from the analysis. Heart rate was 64.3±11.9 bpm and radiation dose was 7.2±2.1 mSv. Disease prevalence was 30% (48/160). Sensitivity, specificity and positive and negative predictive values of CTCA in detecting significant stenosis were 90.1%, 93.3%, 53.2% and 99.1% (per segment), 97.5%, 91.2%, 61.4% and 99.6% (per vessel) and 100%, 83%, 71.6% and 100% (per patient), respectively. Positive and negative likelihood ratios at the per-patient level were 5.89 and 0.0, respectively. CTCA with second-generation DSCT in the real clinical world shows a diagnostic performance comparable with previously reported validation studies. The excellent negative predictive value and likelihood ratio make CTCA a first-line noninvasive method for diagnosing obstructive CAD.

  3. Diagnostic performance of coronary CT angiography carried out with a novel whole-heart coverage high-definition CT scanner in patients with high heart rate.

    PubMed

    Andreini, Daniele; Mushtaq, Saima; Pontone, Gianluca; Conte, Edoardo; Guglielmo, Marco; Annoni, Andrea; Baggiano, Andrea; Formenti, Alberto; Ditali, Valentina; Mancini, Maria Elisabetta; Zanchi, Simone; Melotti, Eleonora; Trabattoni, Daniela; Montorsi, Piero; Ravagnani, Paolo Mario; Fiorentini, Cesare; Bartorelli, Antonio L; Pepi, Mauro

    2018-04-15

    Aim of the study was to evaluate image quality, radiation exposure and diagnostic accuracy of coronary CT angiography (CCTA) performed with a novel cardiac CT scanner in patients with very high heart rate (HR). We prospectively enrolled 202 patients (111 men, mean age 66±8years) with suspected coronary artery disease who underwent CCTA with a whole-organ volumetric CT scanner. The HR during the scan was ≥80bpm in 100 patients (Group 1), while it was ≤65bpm in the remaining 102 patients (Group 2). In all patients, image quality score and coronary interpretability were evaluated and effective dose (ED) was recorded. In 86 of the 202 enrolled patients (40 patients in Group 1, 46 patients in Group 2) who were referred for a clinically indicated invasive coronary angiography (ICA) within 6months, diagnostic accuracy of CCTA vs. ICA was evaluated. Mean image quality and coronary interpretability were very high in both Groups (Likert=3.35 vs. 3.39 and 97.3% [1542/1584 segments] and 98% [1569/1600 segments] in Group 1 and Group 2, respectively). Mean ED was lower in Group 2 (1.1±0.5mSv) compared to Group 1 (2.9±1.6mSv). In Group 1, sensitivity and specificity of CCTA for detection of >50% stenosis vs. ICA were 95.2% and 98.9% in a segment-based analysis and 100% and 81.8% in a patient-based analysis, respectively. The whole organ high-definition CT scanner allows evaluating coronary arteries in patients with high HR with excellent image quality, coronary interpretability and low radiation exposure. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Severe coronary vasospasm associated with hyperthyroidism causing myocardial infarction.

    PubMed Central

    Masani, N. D.; Northridge, D. B.; Hall, R. J.

    1995-01-01

    A 48 year old woman presented with angina after an anterior myocardial infarction and was found to be hyperthyroid. Coronary angiography showed a stenosis of the left coronary os and a long, severe stenosis of the left anterior descending artery which was partially relieved by glyceryl trinitrate. Three months later, after radioactive iodine treatment had rendered her euthyroid, repeat coronary angiography showed entirely normal coronary arteries. This unusual case establishes an association between hyperthyroidism and coronary vasospasm resulting in myocardial infarction. Images PMID:8541184

  5. Timing of angiography with a routine invasive strategy and long-term outcomes in non-ST-segment elevation acute coronary syndrome: a collaborative analysis of individual patient data from the FRISC II (Fragmin and Fast Revascularization During Instability in Coronary Artery Disease), ICTUS (Invasive Versus Conservative Treatment in Unstable Coronary Syndromes), and RITA-3 (Intervention Versus Conservative Treatment Strategy in Patients With Unstable Angina or Non-ST Elevation Myocardial Infarction) Trials.

    PubMed

    Damman, Peter; van Geloven, Nan; Wallentin, Lars; Lagerqvist, Bo; Fox, Keith A A; Clayton, Tim; Pocock, Stuart J; Hirsch, Alexander; Windhausen, Fons; Tijssen, Jan G P; de Winter, Robbert J

    2012-02-01

    This study sought to investigate long-term outcomes after early or delayed angiography in patients with non-ST-segment elevation acute coronary syndrome (nSTE-ACS) undergoing a routine invasive management. The optimal timing of angiography in patients with nSTE-ACS is currently a topic for debate. Long-term follow-up after early (within 2 days) angiography versus delayed (within 3 to 5 days) angiography was investigated in the FRISC-II (Fragmin and Fast Revascularization During Instability in Coronary Artery Disease), ICTUS (Invasive Versus Conservative Treatment in Unstable Coronary Syndromes), and RITA-3 (Intervention Versus Conservative Treatment Strategy in Patients With Unstable Angina or Non-ST Elevation Myocardial Infarction) (FIR) nSTE-ACS patient-pooled database. The main outcome was cardiovascular death or myocardial infarction up to 5-year follow-up. Hazard ratios (HR) were calculated with Cox regression models. Adjustments were made for the FIR risk score, study, and the propensity of receiving early angiography using inverse probability weighting. Of 2,721 patients originally randomized to the routine invasive arm, consisting of routine angiography and subsequent revascularization if suitable, 975 underwent early angiography and 1,141 delayed angiography. No difference was observed in 5-year cardiovascular death or myocardial infarction in unadjusted (HR: 1.06, 95% confidence interval [CI]: 0.79 to 1.42, p=0.61) and adjusted (HR: 0.93, 95% CI: 0.75 to 1.16, p=0.54) Cox regression models. In the FIR database of patients presenting with nSTE-ACS, the timing of angiography was not related to long-term cardiovascular mortality or myocardial infarction. (Invasive Versus Conservative Treatment in Unstable Coronary Syndromes [ICTUS]; ISRCTN82153174. Intervention Versus Conservative Treatment Strategy in Patients With Unstable Angina or Non-ST Elevation Myocardial Infarction [the Third Randomised Intervention Treatment of Angina Trials (RITA-3)]; ISRCTN

  6. A New Hard X-ray Wiggler for DORIS III

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tischer, M.; Gumprecht, L.; Pflueger, J.

    2007-01-19

    A 4 m long hard X-ray wiggler has been built and installed in the DORIS III storage ring at DESY. The device replaces an old wiggler especially designed for angiography studies. Future use of this beamline at the HARWI straight section has been dedicated to hard X-ray scattering and diffraction experiments for material science and geological investigations. The required energy range is from 30 keV to about 200 keV with emphasis on the {approx}100 keV spectral range. The magnet configuration corresponds to a hybrid structure with additional side magnets to achieve a 2 T peak field for the specified periodmore » length of 110 mm. The wiggler position in the storage ring has been moved 8 m upstream into the next cell which allowed for reduction of the minimum magnetic wiggler gap to 14 mm.« less

  7. Multislice coronary computed tomographic angiography in emergency department presentations of unsuspected acute myocardial infarction.

    PubMed

    Hecht, Harvey S; Bhatti, Tandeep

    2009-01-01

    Coronary computed tomographic angiography (CCTA) is not indicated in the setting of acute myocardial infarction in the emergency department (ED). Nonetheless, acute coronary syndromes may have atypical presentations, and CCTA may be inadvertently performed in this setting. This study was designed to determine the frequency and characteristics of CCTA imaging of unsuspected acute myocardial infarction in the ED. All CCTAs performed in the ED at Lenox Hill Hospital were reviewed for clinical indications and subsequent course; patients with documented acute myocardial infarction were identified. Of the 500 CCTAs performed on ED patients in the Lenox Hill laboratory, 5 patients (1%) were imaged during the initial phase of an unsuspected acute myocardial infarction; in all cases the CCTAs were key to the diagnosis. The imaging characteristics were (1) total or subtotal occlusion and (2) transmural hypodensity in the infarct area. Although acute myocardial infarction on CCTA in ED patients is an infrequent event, proper and prompt recognition is critical for appropriate patient care, particularly as applications to the ED increase.

  8. Informed Decision Making for Percutaneous Coronary Intervention for Stable Coronary Disease.

    PubMed

    Rothberg, Michael B; Sivalingam, Senthil K; Kleppel, Reva; Schweiger, Marc; Hu, Bo; Sepucha, Karen R

    2015-07-01

    Patients with stable coronary disease undergoing percutaneous coronary intervention (PCI) are frequently misinformed about the benefits of PCI. Little is known about the quality of decision making before angiography and possible PCI. To assess the quality of informed decision making and its association with patient decisions. We performed a cross-sectional analysis of recorded conversations between August 1, 2008, and August 31, 2012, among adults with known or suspected stable coronary disease at outpatient cardiology practices. Presence of 7 elements of informed decision making and the decision to undergo angiography and possible PCI. Of 59 conversations conducted by 23 cardiologists, 2 (3%) included all 7 elements of informed decision making; 8 (14%) met a more limited definition of procedure, alternatives, and risks. Specific elements significantly associated with not choosing angiography and possible PCI included discussion of uncertainty (odds ratio [OR], 20.5; 95% CI, 2.3-204.9), patient's role (OR, 5.3; 95% CI, 1.3-21.3), exploration of alternatives (OR, 9.5; 95% CI, 2.5-36.5), and exploration of patient preference (OR, 4.8; 95% CI, 1.2-19.4). Neither the presence of angina nor severity of symptoms was associated with choosing angiography and possible PCI. In a multivariable analysis using the total number of elements as a predictor, better informed patients were less likely to choose angiography and possible PCI (OR per additional element, 3.2; 95% CI, 1.4-7.1; P = .005). In conversations between cardiologists and patients with stable angina, informed decision making is often incomplete. More complete discussions are associated with patients choosing not to undergo angiography and possible PCI.

  9. Three dimensional rotational angiography for assessment of coronary arteries during melody valve implantation: introducing a technique that may improve outcomes.

    PubMed

    Pockett, C R; Moore, J W; El-Said, H G

    2017-02-01

    Adverse events from Melody valve implantation may be catastrophic. To date a role for three dimensional rotational angiography of the aortic root (3DRAA) during Melody valve implantation has not been established. To describe the role of 3DRAA in the assessment of Melody valve candidacy and to demonstrate that it may improve outcomes. All patients who underwent cardiac catheterisation for Melody valve implantation and 3DRAA between August 2013 and February 2015 were reviewed. 31 patients had 3DRAA with balloon sizing. Ten were deemed not Melody candidates (5 coronary compression, 2 aortic root distortion with cusp flattening, 2 RVOT was too large, and 1 had complex branch stenosis and a short landing zone). Of the 21 patients who were Melody candidates, 12 had conduits, 6 prosthetic valves and 3 native RVOTs. In patients with conduits, the technique of stenting the conduit prior to dilation was used after measuring the distance between the conduit and the coronary arteries on 3DRAA. In the Melody patients, we had 100% procedural success and no serious adverse events (coronary compression, tears, stent fracture or endocarditis). As a tool for case selection, 3DRAA may facilitate higher procedural success and decreased risk of serious adverse events. Furthermore, 3D rotational angiography allows stenting of the conduit prior to dilation, which may prevent tears and possibly endocarditis.

  10. Influence of adaptive statistical iterative reconstruction algorithm on image quality in coronary computed tomography angiography.

    PubMed

    Precht, Helle; Thygesen, Jesper; Gerke, Oke; Egstrup, Kenneth; Waaler, Dag; Lambrechtsen, Jess

    2016-12-01

    Coronary computed tomography angiography (CCTA) requires high spatial and temporal resolution, increased low contrast resolution for the assessment of coronary artery stenosis, plaque detection, and/or non-coronary pathology. Therefore, new reconstruction algorithms, particularly iterative reconstruction (IR) techniques, have been developed in an attempt to improve image quality with no cost in radiation exposure. To evaluate whether adaptive statistical iterative reconstruction (ASIR) enhances perceived image quality in CCTA compared to filtered back projection (FBP). Thirty patients underwent CCTA due to suspected coronary artery disease. Images were reconstructed using FBP, 30% ASIR, and 60% ASIR. Ninety image sets were evaluated by five observers using the subjective visual grading analysis (VGA) and assessed by proportional odds modeling. Objective quality assessment (contrast, noise, and the contrast-to-noise ratio [CNR]) was analyzed with linear mixed effects modeling on log-transformed data. The need for ethical approval was waived by the local ethics committee as the study only involved anonymously collected clinical data. VGA showed significant improvements in sharpness by comparing FBP with ASIR, resulting in odds ratios of 1.54 for 30% ASIR and 1.89 for 60% ASIR ( P  = 0.004). The objective measures showed significant differences between FBP and 60% ASIR ( P  < 0.0001) for noise, with an estimated ratio of 0.82, and for CNR, with an estimated ratio of 1.26. ASIR improved the subjective image quality of parameter sharpness and, objectively, reduced noise and increased CNR.

  11. Fast frame rate rodent cardiac x-ray imaging using scintillator lens coupled to CMOS camera

    NASA Astrophysics Data System (ADS)

    Swathi Lakshmi, B.; Sai Varsha, M. K. N.; Kumar, N. Ashwin; Dixit, Madhulika; Krishnamurthi, Ganapathy

    2017-03-01

    Micro-Computed Tomography (MCT) systems for small animal imaging plays a critical role for monitoring disease progression and therapy evaluation. In this work, an in-house built micro-CT system equipped with a X-ray scintillator lens coupled to a commercial CMOS camera was used to test the feasibility of its application to Digital Subtraction Angiography (DSA). Literature has reported such studies being done with clinical X-ray tubes that can be pulsed rapidly or with rotating gantry systems, thus increasing the cost and infrastructural requirements.The feasibility of DSA was evaluated by injected Iodinated contrast agent (ICA) through the tail vein of a mouse. Projection images of the heart were acquired pre and post contrast using the high frame rate X-ray detector and processing done to visualize transit of ICA through the heart.

  12. Fourth update on CT angiography of coronary stents: in vitro evaluation of 24 novel stent types.

    PubMed

    Hickethier, Tilman; Wenning, Justus; Doerner, Jonas; Maintz, David; Michels, Guido; Bunck, Alexander C

    2017-01-01

    Background Non-invasive evaluation of coronary stent patency by coronary computed tomography angiography (cCTA) remains challenging. Multiple studies showed that CT technology but also individual stent design strongly influence the assessability of coronary stents by cCTA. Purpose To expand the available data on cCTA characteristics of coronary stents by 24 novel types to help interpreting examinations of patients after stent placement and selecting which stents are suitable for assessment by cCTA. Material and Methods Twenty-four novel coronary stents (17 cobalt-chromium, six stainless-steel, one platinum-chromium) were examined in a coronary phantom. Standard cCTA parameters with stent-specific algorithms were used. Image quality was quantified for each stent using established parameters (in-stent attenuation alteration and visible lumen diameter). Results Most stents (n = 14) showed lumen visibilities of 45-55%. No severe restriction of lumen visibility (>60%) was found. The majority of stents (n = 13) caused only small intraluminal attenuation deviations and no severe alterations (>20%) were found. When grouped by manufacturing material, no significant differences were found between cobalt-chromium and stainless-steel with identical mean visible diameters (1.52 ± 0.17 mm vs. 1.52 ± 0.13 mm) and comparable attenuation alterations (35.04 ± 16.56 HU vs. 21.25 ± 14.60 HU). The only platinum-chromium stent showed a smaller visible diameter (1.23 mm) and higher attenuation alteration (41.70 HU), but was also deemed to be assessable by cCTA. Conclusion All 24 novel evaluated stents are eligible for non-invasive evaluation by cCTA without significant differences between cobalt-chromium and stainless-steel stents. This updated catalogue of CT appearances of current coronary stents may serve as reference when taking care of patients with stents in need of coronary imaging.

  13. X-Rays

    MedlinePlus

    X-rays are a type of radiation called electromagnetic waves. X-ray imaging creates pictures of the inside of ... different amounts of radiation. Calcium in bones absorbs x-rays the most, so bones look white. Fat ...

  14. Methodological quality of diagnostic accuracy studies on non-invasive coronary CT angiography: influence of QUADAS (Quality Assessment of Diagnostic Accuracy Studies included in systematic reviews) items on sensitivity and specificity.

    PubMed

    Schueler, Sabine; Walther, Stefan; Schuetz, Georg M; Schlattmann, Peter; Dewey, Marc

    2013-06-01

    To evaluate the methodological quality of diagnostic accuracy studies on coronary computed tomography (CT) angiography using the QUADAS (Quality Assessment of Diagnostic Accuracy Studies included in systematic reviews) tool. Each QUADAS item was individually defined to adapt it to the special requirements of studies on coronary CT angiography. Two independent investigators analysed 118 studies using 12 QUADAS items. Meta-regression and pooled analyses were performed to identify possible effects of methodological quality items on estimates of diagnostic accuracy. The overall methodological quality of coronary CT studies was merely moderate. They fulfilled a median of 7.5 out of 12 items. Only 9 of the 118 studies fulfilled more than 75 % of possible QUADAS items. One QUADAS item ("Uninterpretable Results") showed a significant influence (P = 0.02) on estimates of diagnostic accuracy with "no fulfilment" increasing specificity from 86 to 90 %. Furthermore, pooled analysis revealed that each QUADAS item that is not fulfilled has the potential to change estimates of diagnostic accuracy. The methodological quality of studies investigating the diagnostic accuracy of non-invasive coronary CT is only moderate and was found to affect the sensitivity and specificity. An improvement is highly desirable because good methodology is crucial for adequately assessing imaging technologies. • Good methodological quality is a basic requirement in diagnostic accuracy studies. • Most coronary CT angiography studies have only been of moderate design quality. • Weak methodological quality will affect the sensitivity and specificity. • No improvement in methodological quality was observed over time. • Authors should consider the QUADAS checklist when undertaking accuracy studies.

  15. A framework for organ dose estimation in x-ray angiography and interventional radiology based on dose-related data in DICOM structured reports

    NASA Astrophysics Data System (ADS)

    Omar, Artur; Bujila, Robert; Fransson, Annette; Andreo, Pedro; Poludniowski, Gavin

    2016-04-01

    Although interventional x-ray angiography (XA) procedures involve relatively high radiation doses that can lead to deterministic tissue reactions in addition to stochastic effects, convenient and accurate estimation of absorbed organ doses has traditionally been out of reach. This has mainly been due to the absence of practical means to access dose-related data that describe the physical context of the numerous exposures during an XA procedure. The present work provides a comprehensive and general framework for the determination of absorbed organ dose, based on non-proprietary access to dose-related data by utilizing widely available DICOM radiation dose structured reports. The framework comprises a straightforward calculation workflow to determine the incident kerma and reconstruction of the geometrical relation between the projected x-ray beam and the patient’s anatomy. The latter is difficult in practice, as the position of the patient on the table top is unknown. A novel patient-specific approach for reconstruction of the patient position on the table is presented. The proposed approach was evaluated for 150 patients by comparing the estimated position of the primary irradiated organs (the target organs) with their position in clinical DICOM images. The approach is shown to locate the target organ position with a mean (max) deviation of 1.3 (4.3), 1.8 (3.6) and 1.4 (2.9) cm for neurovascular, adult and paediatric cardiovascular procedures, respectively. To illustrate the utility of the framework for systematic and automated organ dose estimation in routine clinical practice, a prototype implementation of the framework with Monte Carlo simulations is included.

  16. Effect of music on anxiety, stress, and depression levels in patients undergoing coronary angiography.

    PubMed

    Moradipanah, F; Mohammadi, E; Mohammadil, A Z

    2009-01-01

    Control of stress and anxiety and the promotion of comfort are challenges facing health practitioners involved in catheterization. The aim of this case-control study was to examine the effect of music on the levels of anxiety, stress, and depression experienced by patients undergoing coronary angiography, as measured by the 21-item Depression Anxiety Stress Scales. Differences in pre- and post-intervention scores demonstrated that there were significant decreases in mean scores of state anxiety (P = 0.006), stress (P = 0.001) and depression P = 0.02) in the intervention group, who listened to 20 minutes of relaxing music, as compared with the control group who had 20 minutes of bed rest.

  17. Highly sensitive troponin and coronary computed tomography angiography in the evaluation of suspected acute coronary syndrome in the emergency department.

    PubMed

    Ferencik, Maros; Hoffmann, Udo; Bamberg, Fabian; Januzzi, James L

    2016-08-07

    The evaluation of patients presenting to the emergency department with suspected acute coronary syndrome (ACS) remains a clinical challenge. The traditional assessment includes clinical risk assessment based on cardiovascular risk factors with serial electrocardiograms and cardiac troponin measurements, often followed by advanced cardiac testing as inpatient or outpatient (i.e. stress testing, imaging). Despite this costly and lengthy work-up, there is a non-negligible rate of missed ACS with an increased risk of death. There is a clinical need for diagnostic strategies that will lead to rapid and reliable triage of patients with suspected ACS. We provide an overview of the evidence for the role of highly sensitive troponin (hsTn) in the rapid and efficient evaluation of suspected ACS. Results of recent research studies have led to the introduction of hsTn with rapid rule-in and rule-out protocols into the guidelines. Highly sensitive troponin increases the sensitivity for the detection of myocardial infarction and decreases time to diagnosis; however, it may decrease the specificity, especially when used as a dichotomous variable, rather than continuous variable as recommended by guidelines; this may increase clinician uncertainty. We summarize the evidence for the use of coronary computed tomography angiography (CTA) as the rapid diagnostic tool in this population when used with conventional troponin assays. Coronary CTA significantly decreases time to diagnosis and discharge in patients with suspected ACS, while being safe. However, it may lead to increase in invasive procedures and includes radiation exposure. Finally, we outline the opportunities for the combined use of hsTn and coronary CTA that may result in increased efficiency, decreased need for imaging, lower cost, and decreased radiation dose. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  18. Outcomes after coronary computed tomography angiography in the emergency department: a systematic review and meta-analysis of randomized, controlled trials.

    PubMed

    Hulten, Edward; Pickett, Christopher; Bittencourt, Marcio Sommer; Villines, Todd C; Petrillo, Sara; Di Carli, Marcelo F; Blankstein, Ron

    2013-02-26

    The aim of the study was to systematically review and perform a meta-analysis of randomized, controlled trials of coronary computed tomography angiography (CCTA) versus usual care (UC) triage of acute chest pain in the emergency department (ED). CCTA allows rapid evaluation of patients presenting to the ED with acute chest pain syndromes; however, the impact of such testing on patient management and downstream testing has emerged as a concern. We systematically searched for randomized, controlled trials of CCTA in the ED and performed a meta-analysis of clinical outcomes. Four randomized, controlled trials were included, with 1,869 patients undergoing CCTA and 1,397 undergoing UC. There were no deaths and no difference in the incidence of myocardial infarction, post-discharge ED visits, or rehospitalizations. Four studies reported decreased length of stay with CCTA and 3 reported cost savings; 8.4% of patients undergoing CCTA versus 6.3% of those receiving UC underwent invasive coronary angiography (ICA), whereas 4.6% of patients undergoing CCTA versus 2.6% of those receiving UC underwent coronary revascularization. The odds ratio of ICA for CCTA patients versus UC patients was 1.36 (95% confidence interval [CI]: 1.03 to 1.80, p = 0.030), and for revascularization, it was 1.81 (95% CI: 1.20 to 2.72, p = 0.004). The absolute increase in ICA after CCTA was 21 per 1,000 CCTA patients (95% CI: 1.8 to 44.9), and the number needed to scan was 48. The absolute increase in revascularization after CCTA was 20 per 1,000 patients (95% CI: 5.0 to 41.4); the number needed to scan was 50. Both percutaneous coronary intervention and coronary artery bypass graft surgery independently contributed to the significant increase in revascularization. Compared with UC, the use of CCTA in the ED is associated with decreased ED cost and length of stay but increased ICA and revascularization. Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights

  19. A Combination of Two Rare Coronary Anomalies Makes It Even Rarer: Right Sided Single Coronary Artery with Dual Left Anterior Descending Artery

    PubMed Central

    Addai, Theodore; Kola, Monahar; Raqeem, Muhammad Wajih; Barsamyan, Sergey; Mirrakhimov, Aibek E.

    2016-01-01

    An 82-year-old female with history of hyperlipidemia and hypertension presented to the clinic with chief complaint of nonradiating chest tightness accompanied by exertional dyspnea. Cardiac catheterization showed the absence of left coronary system; the entire coronary system originated from the right aortic sinus as a common trunk which then gave off the right coronary artery and the left main coronary artery. Cardiac catheterization demonstrated also another rare coronary anomaly: dual left anterior descending artery. Patient underwent percutaneous coronary intervention and subsequent multidetector computed tomography angiography confirmed the above angiography findings. Patient was subsequently discharged home on double antiplatelet therapy with aspirin and clopidogrel and has been asymptomatic since then. PMID:27293909

  20. Prognostic and therapeutic implications of statin and aspirin therapy in individuals with nonobstructive coronary artery disease: results from the CONFIRM (COronary CT Angiography EvaluatioN For Clinical Outcomes: An InteRnational Multicenter registry) registry.

    PubMed

    Chow, Benjamin J W; Small, Gary; Yam, Yeung; Chen, Li; McPherson, Ruth; Achenbach, Stephan; Al-Mallah, Mouaz; Berman, Daniel S; Budoff, Matthew J; Cademartiri, Filippo; Callister, Tracy Q; Chang, Hyuk-Jae; Cheng, Victor Y; Chinnaiyan, Kavitha; Cury, Ricardo; Delago, Augustin; Dunning, Allison; Feuchtner, Gundrun; Hadamitzky, Martin; Hausleiter, Jörg; Karlsberg, Ronald P; Kaufmann, Philipp A; Kim, Yong-Jin; Leipsic, Jonathon; LaBounty, Troy; Lin, Fay; Maffei, Erica; Raff, Gilbert L; Shaw, Leslee J; Villines, Todd C; Min, James K

    2015-04-01

    We sought to examine the risk of mortality associated with nonobstructive coronary artery disease (CAD) and to determine the impact of baseline statin and aspirin use on mortality. Coronary computed tomographic angiography permits direct visualization of nonobstructive CAD. To date, the prognostic implications of nonobstructive CAD and the potential benefit of directing therapy based on nonobstructive CAD have not been carefully examined. A total of 27 125 consecutive patients who underwent computed tomographic angiography (12 enrolling centers and 6 countries) were prospectively entered into the COronary CT Angiography EvaluatioN For Clinical Outcomes: An InteRnational Multicenter (CONFIRM) registry. Patients, without history of previous CAD or obstructive CAD, for whom baseline statin and aspirin use was available were analyzed. Each coronary segment was classified as normal or nonobstructive CAD (1%-49% stenosis). Patients were followed up for a median of 27.2 months for all-cause mortality. The study comprised 10 418 patients (5712 normal and 4706 with nonobstructive CAD). In multivariable analyses, patients with nonobstructive CAD had a 6% (95% confidence interval, 1%-12%) higher risk of mortality for each additional segment with nonobstructive plaque (P=0.021). Baseline statin use was associated with a reduced risk of mortality (hazard ratio, 0.44; 95% confidence interval, 0.28-0.68; P=0.0003), a benefit that was present for individuals with nonobstructive CAD (hazard ratio, 0.32; 95% confidence interval, 0.19-0.55; P<0.001) but not for those without plaque (hazard ratio, 0.66; 95% confidence interval, 0.30-1.43; P=0.287). When stratified by National Cholesterol Education Program/Adult Treatment Program III, no mortality benefit was observed in individuals without plaque. Aspirin use was not associated with mortality benefit, irrespective of the status of plaque. The presence and extent of nonobstructive CAD predicted mortality. Baseline statin therapy was

  1. High event rate after a first percutaneous coronary intervention in patients with diabetes mellitus: results from the Swedish coronary angiography and angioplasty registry.

    PubMed

    Ritsinger, Viveca; Saleh, Nawsad; Lagerqvist, Bo; Norhammar, Anna

    2015-06-01

    Patients with diabetes mellitus have reduced longevity after acute coronary syndromes and revascularization. However, knowledge of the long-term complication rates and patterns from an everyday life setting is lacking. Consecutive patients undergoing percutaneous coronary intervention included in the Swedish Coronary Angiography Angioplasty Registry (SCAAR) between 2006 and 2010 and with no previous revascularization were prospectively followed up for combined cardiovascular events (first of all-cause mortality, myocardial infarction, stroke, and heart failure) until December 31, 2010. The mean follow-up period was 920 days (SD, 530 days). Differences in background and procedural characteristics were adjusted for in a multivariate Cox regression model. Of 58 891 patients, mean age 67 years, 19% had diabetes mellitus; 27% of them were on diet treatment, 33% on oral glucose lowering, and 40% on insulin treatment. At admission, cardiovascular risk factors, multiple coronary vessel, and left main stem disease were more frequent in patients with diabetes mellitus and their revascularization was less often complete. The adjusted risk for combined cardiovascular events was higher in patients on insulin (hazard ratio [95% confidence interval], 1.63 [1.55-1.72]), on oral treatment (1.23 [1.15-1.31]), and on diet alone (1.21 [1.12-1.29]) compared with patients without diabetes mellitus. Insulin-treated patients ran an increased risk of restenosis (1.54 [1.39-1.71]) and stent thrombosis (1.56 [1.25-1.96]). The prognosis after a first percutaneous coronary intervention is more severe in patients with diabetes mellitus, in particular, in patients treated with insulin, with higher rates of mortality, cardiovascular events, and stent thrombosis over the following 5 years. © 2015 American Heart Association, Inc.

  2. Tradeoff between noise reduction and inartificial visualization in a model-based iterative reconstruction algorithm on coronary computed tomography angiography.

    PubMed

    Hirata, Kenichiro; Utsunomiya, Daisuke; Kidoh, Masafumi; Funama, Yoshinori; Oda, Seitaro; Yuki, Hideaki; Nagayama, Yasunori; Iyama, Yuji; Nakaura, Takeshi; Sakabe, Daisuke; Tsujita, Kenichi; Yamashita, Yasuyuki

    2018-05-01

    We aimed to evaluate the image quality performance of coronary CT angiography (CTA) under the different settings of forward-projected model-based iterative reconstruction solutions (FIRST).Thirty patients undergoing coronary CTA were included. Each image was reconstructed using filtered back projection (FBP), adaptive iterative dose reduction 3D (AIDR-3D), and 2 model-based iterative reconstructions including FIRST-body and FIRST-cardiac sharp (CS). CT number and noise were measured in the coronary vessels and plaque. Subjective image-quality scores were obtained for noise and structure visibility.In the objective image analysis, FIRST-body produced the significantly highest contrast-to-noise ratio. Regarding subjective image quality, FIRST-CS had the highest score for structure visibility, although the image noise score was inferior to that of FIRST-body.In conclusion, FIRST provides significant improvements in objective and subjective image quality compared with FBP and AIDR-3D. FIRST-body effectively reduces image noise, but the structure visibility with FIRST-CS was superior to FIRST-body.

  3. Additional Value of Transluminal Attenuation Gradient in CT Angiography to Predict Hemodynamic Significance of Coronary Artery Stenosis

    PubMed Central

    Stuijfzand, Wynand J.; Danad, Ibrahim; Raijmakers, Pieter G.; Marcu, C. Bogdan; Heymans, Martijn W.; van Kuijk, Cornelis C.; van Rossum, Albert C.; Nieman, Koen; Min, James K.; Leipsic, Jonathon; van Royen, Niels; Knaapen, Paul

    2015-01-01

    OBJECTIVES The current study evaluates the incremental value of transluminal attenuation gradient (TAG), TAG with corrected contrast opacification (CCO), and TAG with exclusion of calcified coronary segments (ExC) over coronary computed tomography angiogram (CTA) alone using fractional flow reserve (FFR) as the gold standard. BACKGROUND TAG is defined as the contrast opacification gradient along the length of a coronary artery on a coronary CTA. Preliminary data suggest that TAG provides additional functional information. Interpretation of TAG is hampered by multiple heartbeat acquisition algorithms and coronary calcifications. Two correction models have been proposed based on either dephasing of contrast delivery by relating coronary density to corresponding descending aortic opacification (TAG-CCO) or excluding calcified coronary segments (TAG-ExC). METHODS Eighty-five patients with intermediate probability of coronary artery disease were prospectively included. All patients underwent step-and-shoot 256-slice coronary CTA. TAG, TAG-CCO, and TAG-ExC analyses were performed followed by invasive coronary angiography in conjunction with FFR measurements of all major coronary branches. RESULTS Thirty-four patients (40%) were diagnosed with hemodynamically-significant coronary artery disease (i.e., FFR ≤0.80). On a per-vessel basis (n = 253), 59 lesions (23%) were graded as hemodynamically significant, and the diagnostic accuracy of coronary CTA (diameter stenosis ≥50%) was 95%, 75%, 98%, and 54% for sensitivity, specificity, negative predictive value, and positive predictive value, respectively. TAG and TAG-ExC did not discriminate between vessels with or without hemodynamically significant lesions (−13.5 ± 17.1 HU [Hounsfield units] × 10 mm−1 vs. −11.6 ± 13.3 HU × 10 mm−1, p = 0.36; and 13.1 ± 15.9 HU × 10 mm−1 vs. −11.4 ± 11.7 HU × 10 mm−1, p = 0.77, respectively). TAG-CCO was lower in vessels with a hemodynamically-significant lesion (−0

  4. Contemporary Patterns of Early Coronary Angiography Use in Patients With Non-ST-Segment Elevation Myocardial Infarction in the United States: Insights From the National Cardiovascular Data Registry Acute Coronary Treatment and Intervention Outcomes Network Registry.

    PubMed

    Malta Hansen, Carolina; Wang, Tracy Y; Chen, Anita Y; Chiswell, Karen; Bhatt, Deepak L; Enriquez, Jonathan R; Henry, Timothy; Roe, Matthew T

    2018-02-26

    The study sought to characterize patient- and hospital-level variation in early angiography use among non-ST-segment elevation myocardial infarction (NSTEMI) patients. Contemporary implementation of guideline recommendations for early angiography use in NSTEMI patients in the United States have not been described. The study analyzed NSTEMI patients included in ACTION (Acute Coronary Treatment and Intervention Outcomes Network) registry (2012 to 2014) who underwent in-hospital angiography. Timing of angiography was categorized as early (≤24 h) vs. delayed (>24 h). The study evaluated factors associated with early angiography, hospital-level variation in early angiography use, and the relationship with quality-of-care measures. A total of 79,760 of 138,688 (57.5%) patients underwent early angiography. Factors most strongly associated with delayed angiography included weekend or holiday presentation, lower initial troponin ratio values, higher initial creatinine values, heart failure on presentation, and older age. Median hospital-level use of early angiography was 58.5% with wide variation across hospitals (21.7% to 100.0%). Patient characteristics did not differ substantially across hospitals grouped by tertiles of early angiography use (low, middle, and high). Hospitals in the highest tertile tended to more commonly use guideline-recommended medications and had higher defect-free care quality scores. In contemporary U.S. practice, high-risk clinical characteristics were associated with lower use of early angiography in NSTEMI patients; hospital-level use of early angiography varied widely despite few differences in case mix. Hospitals that most commonly utilized early angiography also had higher quality-of-care metrics, highlighting the need for improved NSTEMI guideline adherence. Copyright © 2018 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  5. Quantitative assessment on coronary computed tomography angiography (CCTA) image quality: comparisons between genders and different tube voltage settings.

    PubMed

    Chian, Teo Chee; Nassir, Norziana Mat; Ibrahim, Mohd Izuan; Yusof, Ahmad Khairuddin Md; Sabarudin, Akmal

    2017-02-01

    This study was carried out to quantify and compare the quantitative image quality of coronary computed tomography angiography (CCTA) between genders as well as between different tube voltages scan protocols. Fifty-five cases of CCTA were collected retrospectively and all images including reformatted axial images at systolic and diastolic phases as well as images with curved multi planar reformation (cMPR) were obtained. Quantitative image quality including signal intensity, image noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of right coronary artery (RCA), left anterior descending artery (LAD), left circumflex artery (LCx) and left main artery (LM) were quantified using Analyze 12.0 software. Six hundred and fifty-seven coronary arteries were evaluated. There were no significant differences in any quantitative image quality parameters between genders. 100 kilovoltage peak (kVp) scanning protocol produced images with significantly higher signal intensity compared to 120 kVp scanning protocol (P<0.001) in all coronary arteries in all types of images. Higher SNR was also observed in 100 kVp scan protocol in all coronary arteries except in LCx where 120 kVp showed better SNR than 100 kVp. There were no significant differences in image quality of CCTA between genders and different tube voltages. Lower tube voltage (100 kVp) scanning protocol is recommended in clinical practice to reduce the radiation dose to patient.

  6. Operator Radiation and the Efficacy of Ceiling-Suspended Lead Screen Shielding during Coronary Angiography: An Anthropomorphic Phantom Study Using Real-Time Dosimeters

    NASA Astrophysics Data System (ADS)

    Jia, Qianjun; Chen, Ziman; Jiang, Xianxian; Zhao, Zhenjun; Huang, Meiping; Li, Jiahua; Zhuang, Jian; Liu, Xiaoqing; Hu, Tianyu; Liang, Wensheng

    2017-02-01

    Operator radiation and the radiation protection efficacy of a ceiling-suspended lead screen were assessed during coronary angiography (CA) in a catheterization laboratory. An anthropomorphic phantom was placed under the X-ray beam to simulate patient attenuation in eight CA projections. Using real-time dosimeters, radiation dose rates were measured on models mimicking a primary operator (PO) and an assistant. Subsequently, a ceiling-suspended lead screen was placed in three commonly used positions to compare the radiation protection efficacy. The radiation exposure to the PO was 2.3 to 227.9 (mean: 67.2 ± 49.0) μSv/min, with the left anterior oblique (LAO) 45°/cranial 25° and cranial 25° projections causing the highest and the lowest dose rates, respectively. The assistant experienced significantly less radiation overall (mean: 20.1 ± 19.6 μSv/min, P < 0.003), with the right anterior oblique (RAO) 30° and cranial 25° projections resulting in the highest and lowest exposure levels, respectively. Combined with table-side shielding, the ceiling-suspended lead screen reduced the radiation to the PO by 76.8%, 81.9% and 93.5% when placed close to the patient phantom, at the left side and close to the PO, respectively, and reduced the radiation to the assistant by 70.3%, 76.7% and 90.0%, respectively. When placed close to the PO, a ceiling-suspended lead screen provides substantial radiation protection during CA.

  7. Advanced 2-dimensional quantitative coronary angiographic analysis for prediction of fractional flow reserve in intermediate coronary stenoses.

    PubMed

    Opolski, Maksymilian P; Pregowski, Jerzy; Kruk, Mariusz; Kepka, Cezary; Staruch, Adam D; Witkowski, Adam

    2014-07-01

    The widespread clinical application of coronary computed tomography angiography (CCTA) has resulted in increased referral patterns of patients with intermediate coronary stenoses to invasive coronary angiography. We evaluated the application of advanced quantitative coronary angiography (A-QCA) for predicting fractional flow reserve (FFR) in intermediate coronary lesions detected on CCTA. Fifty-six patients with 66 single intermediate coronary lesions (≥ 50% to 80% stenosis) on CCTA prospectively underwent coronary angiography and FFR. A-QCA including calculation of the Poiseuille-based index defined as the ratio of lesion length to the fourth power of the minimal lumen diameter (MLD) was performed. Significant stenosis was defined as FFR ≤ 0.80. The mean FFR was 0.86 ± 0.09, and 18 lesions (27%) were functionally significant. FFR correlated with lesion length (R=-0.303, P=0.013), MLD (R=0.527, P<0.001), diameter stenosis (R=-0.404, P=0.001), minimum lumen area (MLA) (R=0.530, P<0.001), lumen stenosis (R=-0.400, P=0.001), and Poiseuille-based index (R=-0.602, P<0.001). The optimal cutoff values for MLD, MLA, diameter stenosis, and lumen stenosis were ≤ 1.3 mm, ≤ 1.5 mm, >44%, and >69%, respectively (maximum negative predictive value of 94% for MLA, maximum positive predictive value of 58% for diameter stenosis). The Poiseuille-based index was the most accurate (C statistic 0.86, sensitivity 100%, specificity 71%, positive predictive value 56%, and negative predictive value 100%) predictor of FFR ≤ 0.80, but showed the lowest interobserver agreement (intraclass correlation coefficient 0.37). A-QCA might be used to rule out significant ischemia in intermediate stenoses detected by CCTA. The diagnostic application of the Poiseuille-based angiographic index is precluded by its high interobserver variability.

  8. Influence of adaptive statistical iterative reconstruction algorithm on image quality in coronary computed tomography angiography

    PubMed Central

    Thygesen, Jesper; Gerke, Oke; Egstrup, Kenneth; Waaler, Dag; Lambrechtsen, Jess

    2016-01-01

    Background Coronary computed tomography angiography (CCTA) requires high spatial and temporal resolution, increased low contrast resolution for the assessment of coronary artery stenosis, plaque detection, and/or non-coronary pathology. Therefore, new reconstruction algorithms, particularly iterative reconstruction (IR) techniques, have been developed in an attempt to improve image quality with no cost in radiation exposure. Purpose To evaluate whether adaptive statistical iterative reconstruction (ASIR) enhances perceived image quality in CCTA compared to filtered back projection (FBP). Material and Methods Thirty patients underwent CCTA due to suspected coronary artery disease. Images were reconstructed using FBP, 30% ASIR, and 60% ASIR. Ninety image sets were evaluated by five observers using the subjective visual grading analysis (VGA) and assessed by proportional odds modeling. Objective quality assessment (contrast, noise, and the contrast-to-noise ratio [CNR]) was analyzed with linear mixed effects modeling on log-transformed data. The need for ethical approval was waived by the local ethics committee as the study only involved anonymously collected clinical data. Results VGA showed significant improvements in sharpness by comparing FBP with ASIR, resulting in odds ratios of 1.54 for 30% ASIR and 1.89 for 60% ASIR (P = 0.004). The objective measures showed significant differences between FBP and 60% ASIR (P < 0.0001) for noise, with an estimated ratio of 0.82, and for CNR, with an estimated ratio of 1.26. Conclusion ASIR improved the subjective image quality of parameter sharpness and, objectively, reduced noise and increased CNR. PMID:28405477

  9. Cost-effectiveness of coronary CT angiography in patients with chest pain: Comparison with myocardial single photon emission tomography.

    PubMed

    Lee, Seung-Pyo; Jang, Eun Jin; Kim, Yong-Jin; Cha, Myung-Jin; Park, Sun-Young; Song, Hyun Jin; Choi, Ji Eun; Shim, Jung-Im; Ahn, Jeonghoon; Lee, Hyun Joo

    2015-01-01

    Coronary CT angiography (CCTA) has been proven accurate and is incorporated in clinical recommendations for coronary artery disease (CAD) diagnosis workup, but cost-effectiveness data, especially in comparison to other methods such as myocardial single photon emission CT (SPECT) are insufficient. To compare the cost-effectiveness of CCTA and myocardial SPECT in a real-world setting. We performed a retrospective cohort study on consecutive patients with suspected CAD and a pretest probability between 10% and 90%. Test accuracy was compared by correcting referral bias to coronary angiography depending on noninvasive test results based on the Bayes' theorem and also by incorporating 1-year follow-up results. Cost-effectiveness was analyzed using test accuracy and quality-adjusted life year (QALY). The model using diagnostic accuracy used the number of patients accurately diagnosed among 1000 persons as the effect and contained only expenses for diagnostic testing as the cost. In the model using QALY, a decision tree was developed, and the time horizon was 1 year. CCTA was performed in 635 patients and SPECT in 997 patients. An accurate diagnosis per 1000 patients was achieved in 725 patients by CCTA vs 661 patients by SPECT. In the model using diagnostic accuracy, CCTA was more effective and less expensive than SPECT ($725.38 for CCTA vs $661.46 for SPECT). In the model using QALY, CCTA was generally more effective in terms of life quality (0.00221 QALY) and cost ($513) than SPECT. However, cost utility varied among subgroups, with SPECT outperforming CCTA in patients with a pretest probability of 30% to 60% (0.01890 QALY; $113). These results suggest that CCTA may be more cost-effective than myocardial SPECT. Copyright © 2015 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

  10. Dependence of Coronary 3-Dimensional Dose Maps on Coronary Topologies and Beam Set in Breast Radiation Therapy: A Study Based on CT Angiographies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moignier, Alexandra, E-mail: alexandra.moignier@gmail.com; Broggio, David; Derreumaux, Sylvie

    2014-05-01

    Purpose: In left-side breast radiation therapy (RT), doses to the left main (LM) and left anterior descending (LAD) coronary arteries are usually assessed after delineation by prior anatomic knowledge on the treatment planning computed tomography (CT) scan. In this study, dose sensitivity due to interindividual coronary topology variation was assessed, and hot spots were located. Methods and Materials: Twenty-two detailed heart models, created from heart computed tomography angiographies, were fitted into a single representative female thorax. Two breast RT protocols were then simulated into a treatment planning system: the first protocol comprised tangential and tumoral bed beams (TGs{sub T}B) atmore » 50 + 16 Gy, the second protocol added internal mammary chain beams at 50 Gy to TGs{sub T}B (TGs{sub T}B{sub I}MC). For the heart, the LAD, and the LM, several dose indicators were calculated: dose-volume histograms, mean dose (D{sub mean}), minimal dose received by the most irradiated 2% of the volume (D{sub 2%}), and 3-dimensional (3D) dose maps. Variations of these indicators with anatomies were studied. Results: For the LM, the intermodel dispersion of D{sub mean} and D{sub 2%} was 10% and 11%, respectively, with TGs{sub T}B and 40% and 80%, respectively, with TGs{sub T}B{sub I}MC. For the LAD, these dispersions were 19% (D{sub mean}) and 49% (D{sub 2%}) with TGs{sub T}B and 35% (D{sub mean}) and 76% (D{sub 2%}) with TGs{sub T}B{sub I}MC. The 3D dose maps revealed that the internal mammary chain beams induced hot spots between 20 and 30 Gy on the LM and the proximal LAD for some coronary topologies. Without IMC beams, hot spots between 5 and 26 Gy are located on the middle and distal LAD. Conclusions: Coronary dose distributions with hot spot location and dose level can change significantly depending on coronary topology, as highlighted by 3D coronary dose maps. In clinical practice, coronary imaging may be required for a relevant coronary dose assessment

  11. Routine intraoperative completion angiography after coronary artery bypass grafting and 1-stop hybrid revascularization results from a fully integrated hybrid catheterization laboratory/operating room.

    PubMed

    Zhao, David X; Leacche, Marzia; Balaguer, Jorge M; Boudoulas, Konstantinos D; Damp, Julie A; Greelish, James P; Byrne, John G; Ahmad, Rashid M; Ball, Stephen K; Cleator, John H; Deegan, Robert J; Eagle, Susan S; Fong, Pete P; Fredi, Joseph L; Hoff, Steven J; Jennings, Henry S; McPherson, John A; Piana, Robert N; Pretorius, Mias; Robbins, Mark A; Slosky, David A; Thompson, Annemarie

    2009-01-20

    This study sought to report our experience with a routine completion angiogram after coronary artery bypass surgery (CABG) and simultaneous (1-stop) percutaneous coronary intervention (PCI) at the time of CABG performed in the hybrid catheterization laboratory/operating room. The value of a routine completion angiogram after CABG and 1-stop hybrid CABG/PCI remains unresolved. Between April 2005 and July 2007, 366 consecutive patients underwent CABG surgery, with (n = 112) or without (n = 254) concomitant 1-stop PCI (hybrid), all with completion angiography before chest closure. Among the 112 1-stop hybrid CABG/PCI patients, 67 (60%) underwent a planned hybrid procedure based on pre-operative assessment, whereas 45 (40%) underwent open-chest PCI (unplanned hybrid) based on intraoperative findings. Among the 796 CABG grafts (345 left internal mammary artery, 12 right internal mammary artery/radial, and 439 veins), 97 (12%) angiographic defects were identified. Defects were repaired with either a minor adjustment of the graft (n = 22, 2.8%), with intraoperative open-chest PCI (unplanned hybrid, n = 48, 6%) or with traditional surgical revision (n = 27, 3.4%). Hybrid patients had clinical outcomes similar to standard CABG patients. Routine completion angiography detected 12% of grafts with important angiographic defects. One-stop hybrid coronary revascularization is reasonable, safe, and feasible. Combining the tools of the catheterization laboratory and operating room greatly enhances the options available to the surgeon and cardiologist for patients with complex coronary artery disease.

  12. Coronary heart disease is not significantly linked to acute kidney injury identified using Acute Kidney Injury Group criteria.

    PubMed

    Yayan, Josef

    2012-01-01

    Patients with unstable angina or myocardial infarction are at risk of acute kidney injury, which may be aggravated by the iodine-containing contrast agent used during coronary angiography; however, the relationship between these two conditions remains unclear. The current study investigated the relationship between acute kidney injury and coronary heart disease prior to coronary angiography. All patients were evaluated after undergoing coronary angiography in the cardiac catheterization laboratory of the Vinzentius Hospital in Landau, Germany, in 2011. The study group included patients with both acute coronary heart disease and acute kidney injury (as defined according to the classification of the Acute Kidney Injury Group); the control group included patients without acute coronary heart disease. Serum creatinine profiles were evaluated in all patients, as were a variety of demographic and health characteristics. Of the 303 patients examined, 201 (66.34%) had coronary artery disease. Of these, 38 (18.91%) also had both acute kidney injury and acute coronary heart disease prior to and after coronary angiography, and of which in turn 34 (16.91%) had both acute kidney injury and acute coronary heart disease only prior to the coronary angiography. However, the occurrence of acute kidney injury was not significantly related to the presence of coronary heart disease (P = 0.95, Chi-square test). The results of this study indicate that acute kidney injury is not linked to acute coronary heart disease. However, physicians should be aware that many coronary heart patients may develop kidney injury while hospitalized for angiography.

  13. Optical coherence tomography compared with intravascular ultrasound and with angiography to guide coronary stent implantation (ILUMIEN III: OPTIMIZE PCI): a randomised controlled trial.

    PubMed

    Ali, Ziad A; Maehara, Akiko; Généreux, Philippe; Shlofmitz, Richard A; Fabbiocchi, Franco; Nazif, Tamim M; Guagliumi, Giulio; Meraj, Perwaiz M; Alfonso, Fernando; Samady, Habib; Akasaka, Takashi; Carlson, Eric B; Leesar, Massoud A; Matsumura, Mitsuaki; Ozan, Melek Ozgu; Mintz, Gary S; Ben-Yehuda, Ori; Stone, Gregg W

    2016-11-26

    Percutaneous coronary intervention (PCI) is most commonly guided by angiography alone. Intravascular ultrasound (IVUS) guidance has been shown to reduce major adverse cardiovascular events (MACE) after PCI, principally by resulting in a larger postprocedure lumen than with angiographic guidance. Optical coherence tomography (OCT) provides higher resolution imaging than does IVUS, although findings from some studies suggest that it might lead to smaller luminal diameters after stent implantation. We sought to establish whether or not a novel OCT-based stent sizing strategy would result in a minimum stent area similar to or better than that achieved with IVUS guidance and better than that achieved with angiography guidance alone. In this randomised controlled trial, we recruited patients aged 18 years or older undergoing PCI from 29 hospitals in eight countries. Eligible patients had one or more target lesions located in a native coronary artery with a visually estimated reference vessel diameter of 2·25-3·50 mm and a length of less than 40 mm. We excluded patients with left main or ostial right coronary artery stenoses, bypass graft stenoses, chronic total occlusions, planned two-stent bifurcations, and in-stent restenosis. Participants were randomly assigned (1:1:1; with use of an interactive web-based system in block sizes of three, stratified by site) to OCT guidance, IVUS guidance, or angiography-guided stent implantation. We did OCT-guided PCI using a specific protocol to establish stent length, diameter, and expansion according to reference segment external elastic lamina measurements. All patients underwent final OCT imaging (operators in the IVUS and angiography groups were masked to the OCT images). The primary efficacy endpoint was post-PCI minimum stent area, measured by OCT at a masked independent core laboratory at completion of enrolment, in all randomly allocated participants who had primary outcome data. The primary safety endpoint was procedural

  14. Patient-related factors influencing detectability of coronary arteries in 320-row CT angiography in infants with complex congenital heart disease.

    PubMed

    Yamasaki, Yuzo; Kawanami, Satoshi; Kamitani, Takeshi; Sagiyama, Koji; Shin, Seitaro; Hino, Takuya; Nagata, Hazumu; Yabuuchi, Hidetake; Nagao, Michinobu; Honda, Hiroshi

    2018-05-05

    To investigate the performance of second-generation 320-row computed tomographic (CT) angiography (CTA) in detecting coronary arteries and identify factors influencing visibility of the coronary arteries in infants with complex congenital heart disease (CHD). Data of 60 infants (aged 0-2 years, median 2 months) with complex CHD who underwent examination using 320-row CTA with low-dose prospective electrocardiogram-triggered volume target scanning were reviewed. The coronary arteries of each infant were assessed using a 0-4-point scoring system based on the number of coronary segments with a visible course. Clinical parameters, the CT value in the ascending aorta, image noise, and the radiation dose were subjected to univariate and multivariate analyses. The mean coronary score for all examinations was 2.6 ± 1.5 points. The mean attenuation in the ascending aorta was 306.7 ± 66.2 HU and the mean standard deviation was 21.7 ± 4.4. The mean effective radiation dose was 1.27 ± 0.39 mSv. Multivariate regression analysis showed significant correlations between coronary score and body weight (p < 0.05) and between coronary score and the CT value in the ascending aorta (p < 0.02). Second-generation 320-row CTA with prospective electrocardiogram-triggered volume target scanning and hybrid iterative reconstruction allows good visibility of the coronary arteries in infants with complex CHD. Body weight and the CT value in the ascending aorta are important factors influencing the visibility of the coronary arteries in infants.

  15. X-ray beamsplitter

    DOEpatents

    Ceglio, Natale M.; Stearns, Daniel S.; Hawryluk, Andrew M.; Barbee, Jr., Troy W.

    1989-01-01

    An x-ray beamsplitter which splits an x-ray beam into two coherent parts by reflecting and transmitting some fraction of an incident beam has applications for x-ray interferometry, x-ray holography, x-ray beam manipulation, and x-ray laser cavity output couplers. The beamsplitter is formed of a wavelength selective multilayer thin film supported by a very thin x-ray transparent membrane. The beamsplitter resonantly transmits and reflects x-rays through thin film interference effects. A thin film is formed of 5-50 pairs of alternate Mo/Si layers with a period of 20-250 A. The support membrane is 10-200 nm of silicon nitride or boron nitride. The multilayer/support membrane structure is formed across a window in a substrate by first forming the structure on a solid substrate and then forming a window in the substrate to leave a free-standing structure over the window.

  16. Ontario multidetector computed tomographic coronary angiography study: field evaluation of diagnostic accuracy.

    PubMed

    Chow, Benjamin J W; Freeman, Michael R; Bowen, James M; Levin, Leslie; Hopkins, Robert B; Provost, Yves; Tarride, Jean-Eric; Dennie, Carole; Cohen, Eric A; Marcuzzi, Dan; Iwanochko, Robert; Moody, Alan R; Paul, Narinder; Parker, John D; O'Reilly, Daria J; Xie, Feng; Goeree, Ron

    2011-06-13

    Computed tomographic coronary angiography (CTCA) has gained clinical acceptance for the detection of obstructive coronary artery disease. Although single-center studies have demonstrated excellent accuracy, multicenter studies have yielded variable results. The true diagnostic accuracy of CTCA in the "real world" remains uncertain. We conducted a field evaluation comparing multidetector CTCA with invasive CA (ICA) to understand CTCA's diagnostic accuracy in a real-world setting. A multicenter cohort study of patients awaiting ICA was conducted between September 2006 and June 2009. All patients had either a low or an intermediate pretest probability for coronary artery disease and underwent CTCA and ICA within 10 days. The results of CTCA and ICA were interpreted visually by local expert observers who were blinded to all clinical data and imaging results. Using a patient-based analysis (diameter stenosis ≥50%) of 169 patients, the sensitivity, specificity, positive predictive value, and negative predictive value were 81.3% (95% confidence interval [CI], 71.0%-89.1%), 93.3% (95% CI, 85.9%-97.5%), 91.6% (95% CI, 82.5%-96.8%), and 84.7% (95% CI, 76.0%-91.2%), respectively; the area under receiver operating characteristic curve was 0.873. The diagnostic accuracy varied across centers (P < .001), with a sensitivity, specificity, positive predictive value, and negative predictive value ranging from 50.0% to 93.2%, 92.0% to 100%, 84.6% to 100%, and 42.9% to 94.7%, respectively. Compared with ICA, CTCA appears to have good accuracy; however, there was variability in diagnostic accuracy across centers. Factors affecting institutional variability need to be better understood before CTCA is universally adopted. Additional real-world evaluations are needed to fully understand the impact of CTCA on clinical care. clinicaltrials.gov Identifier: NCT00371891.

  17. Search for Hard X-Ray Emission from the Soft X-Ray Transient Aquila X-1

    NASA Astrophysics Data System (ADS)

    Harmon, B. A.; Zhang, S. N.; Paciesas, W. S.; Tavani, M.; Kaaret, P.; Ford, E.

    1994-12-01

    We are investigating the possibility of hard x-ray emission from the recurrent soft x-ray transient and x-ray burst source Aquila X-1 (Aql X-1). Outbursts of this source are relatively frequent with a spacing of ~ 4-10 months (Kitamoto, S. et al. 1993, ApJ, 403, 315). The recent detections of hard tails (\\(>\\)20 keV) in low luminosity x-ray bursters (Barret, D. & Vedrenne, G. 1994, ApJ Supp. S. 92, 505) suggest that neutron star transient systems such as Aql X-1 can produce hard x-ray emission which is detectable by BATSE. We are correlating reported optical and soft x-ray observations since 1991 of Aql X-1 with BATSE observations in order to search for hard x-ray emission episodes, and to study their temporal and spectral evolution. We will present preliminary results of this search in the 20-1000 keV band using the Earth occultation technique applied to the large area detectors. If this work is successful, we hope to alert the astronomical community for the next Aql X-1 outburst expected in 1995. Simultaneous x-ray/hard x-ray and optical observations of Aql X-1 during outburst would be of great importance for the modeling of soft x-ray transients and related systems.

  18. TH-F-209-01: Pitfalls: Reliability and Performance of Diagnostic X-Ray Sources

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Behling, R.

    Purpose: Performance and reliability of medical X-ray tubes for imaging are crucial from an ethical, clinical and economic perspective. This lecture will deliver insight into the aspects to consider during the decision making process to invest in X-ray imaging equipment. Outdated metric still hampers realistic product comparison. It is time to change this and to comply with latest standards, which consider current technology. Failure modes and ways to avoid down-time of the equipment shall be discussed. In view of the increasing number of interventional procedures and the hazards associated with ionizing radiation, toxic contrast agents, and the combination thereof, themore » aspect of system reliability is of paramount importance. Methods: A comprehensive picture of trends for different modalities (CT, angiography, general radiology) has been drawn and led to the development of novel X-ray tube technology. Results: Recent X-ray tubes feature enhanced reliability and unprecedented performance. Relevant metrics for product comparison still have to be implemented in practice. Conclusion: The speed of scientific and industrial development of new diagnostic and therapeutic X-ray sources remains tremendous. Still, users suffer from gaps between desire and reality in day-to-day diagnostic routine. X-ray sources are still limiting cutting-edge medical procedures. Side-effects of wear and tear, limitations of the clinical work flow, costs, the characteristics of the X-ray spectrum and others topics need to be further addressed. New applications and modalities, like detection-based color-resolved X-ray and phase-contrast / dark-field imaging will impact the course of new developments of X-ray sources. Learning Objectives: Understand the basic requirements on medical diagnostic X-ray sources per modality Learn to select the optimal equipment employing state-of-the-art metric Know causes of failures, depending on the way X-ray sources are operated Understand methods to

  19. TH-F-209-00: Pitfalls: Reliability and Performance of Diagnostic X-Ray Sources

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    Purpose: Performance and reliability of medical X-ray tubes for imaging are crucial from an ethical, clinical and economic perspective. This lecture will deliver insight into the aspects to consider during the decision making process to invest in X-ray imaging equipment. Outdated metric still hampers realistic product comparison. It is time to change this and to comply with latest standards, which consider current technology. Failure modes and ways to avoid down-time of the equipment shall be discussed. In view of the increasing number of interventional procedures and the hazards associated with ionizing radiation, toxic contrast agents, and the combination thereof, themore » aspect of system reliability is of paramount importance. Methods: A comprehensive picture of trends for different modalities (CT, angiography, general radiology) has been drawn and led to the development of novel X-ray tube technology. Results: Recent X-ray tubes feature enhanced reliability and unprecedented performance. Relevant metrics for product comparison still have to be implemented in practice. Conclusion: The speed of scientific and industrial development of new diagnostic and therapeutic X-ray sources remains tremendous. Still, users suffer from gaps between desire and reality in day-to-day diagnostic routine. X-ray sources are still limiting cutting-edge medical procedures. Side-effects of wear and tear, limitations of the clinical work flow, costs, the characteristics of the X-ray spectrum and others topics need to be further addressed. New applications and modalities, like detection-based color-resolved X-ray and phase-contrast / dark-field imaging will impact the course of new developments of X-ray sources. Learning Objectives: Understand the basic requirements on medical diagnostic X-ray sources per modality Learn to select the optimal equipment employing state-of-the-art metric Know causes of failures, depending on the way X-ray sources are operated Understand methods to

  20. Advantage of vein grafts for anomalous origin of a right coronary artery.

    PubMed

    Kansaku, Rei; Saitoh, Hirofumi; Eguchi, Shoji; Maruyama, Yukio; Ohtsuka, Hideaki; Higuchi, Kotaro

    2009-03-01

    A 66-year-old man with anomalous origin of the right coronary artery suffered from chest pain. The results of coronary angiography and multidetector computer tomography indicated that the proximal right coronary artery was intermittently compressed, causing the ischemia. Coronary artery bypass grafting was regarded as a reliable treatment compared with percutaneous coronary intervention or other surgeries. Because of plentiful flow of the right coronary artery, we decided to use a vein graft to avoid competitive flow. Postoperative coronary angiography revealed intact flow in both the native coronary artery and the vein graft 1 year after the surgery. The myocardial ischemia seen on scintigraphy and the chest pain had disappeared.

  1. X-ray beamsplitter

    DOEpatents

    Ceglio, N.M.; Stearns, D.G.; Hawryluk, A.M.; Barbee, T.W. Jr.

    1987-08-07

    An x-ray beamsplitter which splits an x-ray beam into two coherent parts by reflecting and transmitting some fraction of an incident beam has applications for x-ray interferometry, x-ray holography, x-ray beam manipulation, and x-ray laser cavity output couplers. The beamsplitter is formed of a wavelength selective multilayer thin film supported by a very thin x-ray transparent membrane. The beamsplitter resonantly transmits and reflects x-rays through thin film interference effects. A thin film is formed of 5--50 pairs of alternate Mo/Si layers with a period of 20--250 A. The support membrane is 10--200 nm of silicon nitride or boron nitride. The multilayer/support membrane structure is formed across a window in a substrate by first forming the structure on a solid substrate and then forming a window in the substrate to leave a free-standing structure over the window. 6 figs.

  2. Radiation dose and image quality of X-ray volume imaging systems: cone-beam computed tomography, digital subtraction angiography and digital fluoroscopy.

    PubMed

    Paul, Jijo; Jacobi, Volkmar; Farhang, Mohammad; Bazrafshan, Babak; Vogl, Thomas J; Mbalisike, Emmanuel C

    2013-06-01

    Radiation dose and image quality estimation of three X-ray volume imaging (XVI) systems. A total of 126 patients were examined using three XVI systems (groups 1-3) and their data were retrospectively analysed from 2007 to 2012. Each group consisted of 42 patients and each patient was examined using cone-beam computed tomography (CBCT), digital subtraction angiography (DSA) and digital fluoroscopy (DF). Dose parameters such as dose-area product (DAP), skin entry dose (SED) and image quality parameters such as Hounsfield unit (HU), noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were estimated and compared using appropriate statistical tests. Mean DAP and SED were lower in recent XVI than its previous counterparts in CBCT, DSA and DF. HU of all measured locations was non-significant between the groups except the hepatic artery. Noise showed significant difference among groups (P < 0.05). Regarding CNR and SNR, the recent XVI showed a higher and significant difference compared to its previous versions. Qualitatively, CBCT showed significance between versions unlike the DSA and DF which showed non-significance. A reduction of radiation dose was obtained for the recent-generation XVI system in CBCT, DSA and DF. Image noise was significantly lower; SNR and CNR were higher than in previous versions. The technological advancements and the reduction in the number of frames led to a significant dose reduction and improved image quality with the recent-generation XVI system. • X-ray volume imaging (XVI) systems are increasingly used for interventional radiological procedures. • More modern XVI systems use lower radiation doses compared with earlier counterparts. • Furthermore more modern XVI systems provide higher image quality. • Technological advances reduce radiation dose and improve image quality.

  3. CT Angiography after 20 Years

    PubMed Central

    Rubin, Geoffrey D.; Leipsic, Jonathon; Schoepf, U. Joseph; Fleischmann, Dominik; Napel, Sandy

    2015-01-01

    Through a marriage of spiral computed tomography (CT) and graphical volumetric image processing, CT angiography was born 20 years ago. Fueled by a series of technical innovations in CT and image processing, over the next 5–15 years, CT angiography toppled conventional angiography, the undisputed diagnostic reference standard for vascular disease for the prior 70 years, as the preferred modality for the diagnosis and characterization of most cardiovascular abnormalities. This review recounts the evolution of CT angiography from its development and early challenges to a maturing modality that has provided unique insights into cardiovascular disease characterization and management. Selected clinical challenges, which include acute aortic syndromes, peripheral vascular disease, aortic stent-graft and transcatheter aortic valve assessment, and coronary artery disease, are presented as contrasting examples of how CT angiography is changing our approach to cardiovascular disease diagnosis and management. Finally, the recently introduced capabilities for multispectral imaging, tissue perfusion imaging, and radiation dose reduction through iterative reconstruction are explored with consideration toward the continued refinement and advancement of CT angiography. PMID:24848958

  4. X-Ray Polarization from High Mass X-Ray Binaries

    NASA Technical Reports Server (NTRS)

    Kallman, T.; Dorodnitsyn, A.; Blondin, J.

    2015-01-01

    X-ray astronomy allows study of objects which may be associated with compact objects, i.e. neutron stars or black holes, and also may contain strong magnetic fields. Such objects are categorically non-spherical, and likely non-circular when projected on the sky. Polarization allows study of such geometric effects, and X-ray polarimetry is likely to become feasible for a significant number of sources in the future. A class of potential targets for future X-ray polarization observations is the high mass X-ray binaries (HMXBs), which consist of a compact object in orbit with an early type star. In this paper we show that X-ray polarization from HMXBs has a distinct signature which depends on the source inclination and orbital phase. The presence of the X-ray source displaced from the star creates linear polarization even if the primary wind is spherically symmetric whenever the system is viewed away from conjunction. Direct X-rays dilute this polarization whenever the X-ray source is not eclipsed; at mid-eclipse the net polarization is expected to be small or zero if the wind is circularly symmetric around the line of centers. Resonance line scattering increases the scattering fraction, often by large factors, over the energy band spanned by resonance lines. Real winds are not expected to be spherically symmetric, or circularly symmetric around the line of centers, owing to the combined effects of the compact object gravity and ionization on the wind hydrodynamics. A sample calculation shows that this creates polarization fractions ranging up to tens of percent at mid-eclipse.

  5. Quantitative assessment on coronary computed tomography angiography (CCTA) image quality: comparisons between genders and different tube voltage settings

    PubMed Central

    Chian, Teo Chee; Nassir, Norziana Mat; Ibrahim, Mohd Izuan; Yusof, Ahmad Khairuddin Md

    2017-01-01

    Background This study was carried out to quantify and compare the quantitative image quality of coronary computed tomography angiography (CCTA) between genders as well as between different tube voltages scan protocols. Methods Fifty-five cases of CCTA were collected retrospectively and all images including reformatted axial images at systolic and diastolic phases as well as images with curved multi planar reformation (cMPR) were obtained. Quantitative image quality including signal intensity, image noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of right coronary artery (RCA), left anterior descending artery (LAD), left circumflex artery (LCx) and left main artery (LM) were quantified using Analyze 12.0 software. Results Six hundred and fifty-seven coronary arteries were evaluated. There were no significant differences in any quantitative image quality parameters between genders. 100 kilovoltage peak (kVp) scanning protocol produced images with significantly higher signal intensity compared to 120 kVp scanning protocol (P<0.001) in all coronary arteries in all types of images. Higher SNR was also observed in 100 kVp scan protocol in all coronary arteries except in LCx where 120 kVp showed better SNR than 100 kVp. Conclusions There were no significant differences in image quality of CCTA between genders and different tube voltages. Lower tube voltage (100 kVp) scanning protocol is recommended in clinical practice to reduce the radiation dose to patient. PMID:28275559

  6. Be/X-ray Binary Science for Future X-ray Timing Missions

    NASA Technical Reports Server (NTRS)

    Wilson-Hodge, Colleen A.

    2011-01-01

    For future missions, the Be/X-ray binary community needs to clearly define our science priorities for the future to advocate for their inclusion in future missions. In this talk, I will describe current designs for two potential future missions and Be X-ray binary science enabled by these designs. The Large Observatory For X-ray Timing (LOFT) is an X-ray timing mission selected in February 2011 for the assessment phase from the 2010 ESA M3 call for proposals. The Advanced X-ray Timing ARray (AXTAR) is a NASA explorer concept X-ray timing mission. This talk is intended to initiate discussions of our science priorities for the future.

  7. Spontaneous Coronary Dissection: "Live Flash" Optical Coherence Tomography Guided Angioplasty.

    PubMed

    Bento, Angela Pimenta; Fernandes, Renato Gil Dos Santos Pinto; Neves, David Cintra Henriques Silva; Patrício, Lino Manuel Ribeiro; de Aguiar, José Eduardo Chambel

    2016-01-01

    Optical Coherence tomography (OCT) is a light-based imaging modality which shows tremendous potential in the setting of coronary imaging. Spontaneous coronary artery dissection (SCAD) is an infrequent cause of acute coronary syndrome (ACS). The diagnosis of SCAD is made mainly with invasive coronary angiography, although adjunctive imaging modalities such as computed tomography angiography, IVUS, and OCT may increase the diagnostic yield. The authors describe a clinical case of a young woman admitted with the diagnosis of ACS. The ACS was caused by SCAD detected in the coronary angiography and the angioplasty was guided by OCT. OCT use in the setting of SCAD has been already described and the true innovation in this case was this unique use of OCT. The guidance of angioplasty with live and short images was very useful as it allowed clearly identifying the position of the guidewires at any given moment without the use of prohibitive amounts of contrast.

  8. Abdomen X-Ray (Radiography)

    MedlinePlus

    ... News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Abdomen Abdominal x-ray uses a ... of an abdominal x-ray? What is abdominal x-ray? An x-ray (radiograph) is a noninvasive ...

  9. A search for X-ray polarization in cosmic X-ray sources. [binary X-ray sources and supernovae remnants

    NASA Technical Reports Server (NTRS)

    Hughes, J. P.; Long, K. S.; Novick, R.

    1983-01-01

    Fifteen strong X-ray sources were observed by the X-ray polarimeters on board the OSO-8 satellite from 1975 to 1978. The final results of this search for X-ray polarization in cosmic sources are presented in the form of upper limits for the ten sources which are discussed elsewhere. These limits in all cases are consistent with a thermal origin for the X-ray emission.

  10. X-Ray Emission from the Soft X-Ray Transient Aquila X-1

    NASA Technical Reports Server (NTRS)

    Tavani, Marco

    1998-01-01

    Aquila X-1 is the most prolific of soft X-ray transients. It is believed to contain a rapidly spinning neutron star sporadically accreting near the Eddington limit from a low-mass companion star. The interest in studying the repeated X-ray outbursts from Aquila X-1 is twofold: (1) studying the relation between optical, soft and hard X-ray emission during the outburst onset, development and decay; (2) relating the spectral component to thermal and non-thermal processes occurring near the magnetosphere and in the boundary layer of a time-variable accretion disk. Our investigation is based on the BATSE monitoring of Aquila X-1 performed by our group. We observed Aquila X-1 in 1997 and re-analyzed archival information obtained in April 1994 during a period of extraordinary outbursting activity of the source in the hard X-ray range. Our results allow, for the first time for this important source, to obtain simultaneous spectral information from 2 keV to 200 keV. A black body (T = 0.8 keV) plus a broken power-law spectrum describe accurately the 1994 spectrum. Substantial hard X-ray emission is evident in the data, confirming that the accretion phase during sub-Eddington limit episodes is capable of producing energetic hard emission near 5 x 10(exp 35) ergs(exp -1). A preliminary paper summarizes our results, and a more comprehensive account is being written. We performed a theoretical analysis of possible emission mechanisms, and confirmed that a non-thermal emission mechanism triggered in a highly sheared magnetosphere at the accretion disk inner boundary can explain the hard X-ray emission. An anticorrelation between soft and hard X-ray emission is indeed prominently observed as predicted by this model.

  11. Optimal treatment of coronary-to-pulmonary artery fistula: surgery, coil or stent graft?

    PubMed Central

    Lipiec, Piotr; Peruga, Jan Zbigniew; Jaszewski, Ryszard; Pawłowski, Witold; Kasprzak, Jarosław

    2013-01-01

    We report a case of a 57-year-old man with typical angina due to a coronary artery-to-pulmonary artery fistula, which was evident on transthoracic and transesophageal echocardiography with color Doppler flow mapping. The diagnosis was confirmed by coronary angiography. The patient underwent surgical ligation of the fistula. However, repeated transesophageal echocardiography and coronary angiography revealed persistence of the fistula with significant left-to-right shunt. The orifice of the fistula was then obliterated by stent-graft implantation, which was proven successful by angiography and echocardiography. PMID:24570733

  12. "X-Ray Transients in Star-Forming Regions" and "Hard X-Ray Emission from X-Ray Bursters"

    NASA Technical Reports Server (NTRS)

    Halpern, Jules P.; Kaaret, Philip

    1999-01-01

    This grant funded work on the analysis of data obtained with the Burst and Transient Experiment (BATSE) on the Compton Gamma-Ray Observatory. The goal of the work was to search for hard x-ray transients in star forming regions using the all-sky hard x-ray monitoring capability of BATSE. Our initial work lead to the discovery of a hard x-ray transient, GRO J1849-03. Follow-up observations of this source made with the Wide Field Camera on BeppoSAX showed that the source should be identified with the previously known x-ray pulsar GS 1843-02 which itself is identified with the x-ray source X1845-024 originally discovered with the SAS-3 satellite. Our identification of the source and measurement of the outburst recurrence time, lead to the identification of the source as a Be/X-ray binary with a spin period of 94.8 s and an orbital period of 241 days. The funding was used primarily for partial salary and travel support for John Tomsick, then a graduate student at Columbia University. John Tomsick, now Dr. Tomsick, received his Ph.D. from Columbia University in July 1999, based partially on results obtained under this investigation. He is now a postdoctoral research scientist at the University of California, San Diego.

  13. Congenital anomalous aortic origins of the coronary arteries in adults: a Tunisian coronary arteriography study.

    PubMed

    Ouali, Sana; Neffeti, Elyes; Sendid, Karim; Elghoul, Karima; Remedi, Fahmi; Boughzela, Essia

    2009-03-01

    There is a lack of Tunisian data on the frequency and clinical significance of different coronary artery anomalies. All patients who underwent coronary angiography from March 1996 to December 2006 were considered. Only patients with congenital anomalous aortic origin of the coronary artery were included. Among 7330adult patients who underwent diagnostic coronary angiography, 20 (0.27%) patients (13men; mean age 53.3years) had anomalies of the coronary artery origin. The right coronary artery was the vessel involved most frequently (n=10); it originated separately from the left sinus of Valsalva (SV) in three patients and from the posterior sinus of Valsalva in one patient. In the other patients, it arose from the left main coronary artery or its branches in a single coronary artery originating from the left sinus of Valsalva. Isolated anomalous left circumflex artery was the second most frequent anomaly (n=6). Isolated anomalous left anterior descending artery was seen in one patient. A single coronary artery arising from the right SV was seen in three patients. Atheroslerotic lesions were seen in eight cases. Four patients underwent coronary revascularization; the remainder received medical management. All 20 patients are alive and had an uneventful follow-up (mean 34.2months). In Tunisia, the incidence of congenital anomalous aortic origin of the coronary artery in adults is 0.27%. The right coronary artery is involved most frequently. Medical management seems promising.

  14. Two-dimensional real-time imaging system for subtraction angiography using an iodine filter

    NASA Astrophysics Data System (ADS)

    Umetani, Keiji; Ueda, Ken; Takeda, Tohoru; Anno, Izumi; Itai, Yuji; Akisada, Masayoshi; Nakajima, Teiichi

    1992-01-01

    A new type of subtraction imaging system was developed using an iodine filter and a single-energy broad bandwidth monochromatized x ray. The x-ray images of coronary arteries made after intravenous injection of a contrast agent are enhanced by an energy-subtraction technique. Filter chopping of the x-ray beam switches energies rapidly, so that a nearly simultaneous pair of filtered and nonfiltered images can be made. By using a high-speed video camera, a pair of two 512 × 512 pixel images can be obtained within 9 ms. Three hundred eighty-four images (raw data) are stored in a 144-Mbyte frame memory. After phantom studies, in vivo subtracted images of coronary arteries in dogs were obtained at a rate of 15 images/s.

  15. When Do We Really Need Coronary Calcium Scoring Prior to Contrast-Enhanced Coronary Computed Tomography Angiography? Analysis by Age, Gender and Coronary Risk Factors

    PubMed Central

    Iwan, Johannes; Voss, Andreas; Atsiatorme, Edem; Hofmann, Nina P.; Buss, Sebastian J.; Siebert, Stefan; Kauczor, Hans-Ulrich; Giannitsis, Evangelos; Katus, Hugo A.; Korosoglou, Grigorios

    2014-01-01

    Aims To investigate the value of coronary calcium scoring (CCS) as a filter scan prior to coronary computed tomography angiography (CCTA). Methods and Results Between February 2008 and April 2011, 732 consecutive patients underwent clinically indicated CCTA. During this ‘control phase’, CCS was performed in all patients. In patients with CCS≥800, CCTA was not performed. During a subsequent ‘CCTA phase’ (May 2011–May 2012) another 200 consecutive patients underwent CCTA, and CCS was performed only in patients with increased probability for severe calcification according to age, gender and atherogenic risk factors. In patients where CCS was not performed, calcium scoring was performed in contrast-enhanced CCTA images. Significant associations were noted between CCS and age (r = 0.30, p<0.001) and coronary risk factors (χ2 = 37.9; HR = 2.2; 95%CI = 1.7–2.9, p<0.001). Based on these associations, a ≤3% pre-test probability for CCS≥800 was observed for males <61 yrs. and females <79 yrs. According to these criteria, CCS was not performed in 106 of 200 (53%) patients during the ‘CCTA phase’, including 47 (42%) males and 59 (67%) females. This resulted in absolute radiation saving of ∼1 mSv in 75% of patients younger than 60 yrs. Of 106 patients where CCS was not performed, estimated calcium scoring was indeed <800 in 101 (95%) cases. Non-diagnostic image quality due to calcification was similar between the ‘control phase’ and the ‘CCTA’ group (0.25% versus 0.40%, p = NS). Conclusion The value of CCS as a filter for identification of a high calcium score is limited in younger patients with intermediate risk profile. Omitting CCS in such patients can contribute to further dose reduction with cardiac CT studies. PMID:24714677

  16. Lumbosacral spine x-ray

    MedlinePlus

    X-ray - lumbosacral spine; X-ray - lower spine ... The test is done in a hospital x-ray department or your health care provider's office by an x-ray technician. You will be asked to lie on the x-ray ...

  17. CT coronary angiography in patients with suspected angina due to coronary heart disease (SCOT-HEART): an open-label, parallel-group, multicentre trial.

    PubMed

    2015-06-13

    The benefit of CT coronary angiography (CTCA) in patients presenting with stable chest pain has not been systematically studied. We aimed to assess the effect of CTCA on the diagnosis, management, and outcome of patients referred to the cardiology clinic with suspected angina due to coronary heart disease. In this prospective open-label, parallel-group, multicentre trial, we recruited patients aged 18-75 years referred for the assessment of suspected angina due to coronary heart disease from 12 cardiology chest pain clinics across Scotland. We randomly assigned (1:1) participants to standard care plus CTCA or standard care alone. Randomisation was done with a web-based service to ensure allocation concealment. The primary endpoint was certainty of the diagnosis of angina secondary to coronary heart disease at 6 weeks. All analyses were intention to treat, and patients were analysed in the group they were allocated to, irrespective of compliance with scanning. This study is registered with ClinicalTrials.gov, number NCT01149590. Between Nov 18, 2010, and Sept 24, 2014, we randomly assigned 4146 (42%) of 9849 patients who had been referred for assessment of suspected angina due to coronary heart disease. 47% of participants had a baseline clinic diagnosis of coronary heart disease and 36% had angina due to coronary heart disease. At 6 weeks, CTCA reclassified the diagnosis of coronary heart disease in 558 (27%) patients and the diagnosis of angina due to coronary heart disease in 481 (23%) patients (standard care 22 [1%] and 23 [1%]; p<0·0001). Although both the certainty (relative risk [RR] 2·56, 95% CI 2·33-2·79; p<0·0001) and frequency of coronary heart disease increased (1·09, 1·02-1·17; p=0·0172), the certainty increased (1·79, 1·62-1·96; p<0·0001) and frequency seemed to decrease (0·93, 0·85-1·02; p=0·1289) for the diagnosis of angina due to coronary heart disease. This changed planned investigations (15% vs 1%; p<0·0001) and treatments (23

  18. X-ray ptychography

    NASA Astrophysics Data System (ADS)

    Pfeiffer, Franz

    2018-01-01

    X-ray ptychographic microscopy combines the advantages of raster scanning X-ray microscopy with the more recently developed techniques of coherent diffraction imaging. It is limited neither by the fabricational challenges associated with X-ray optics nor by the requirements of isolated specimen preparation, and offers in principle wavelength-limited resolution, as well as stable access and solution to the phase problem. In this Review, we discuss the basic principles of X-ray ptychography and summarize the main milestones in the evolution of X-ray ptychographic microscopy and tomography over the past ten years, since its first demonstration with X-rays. We also highlight the potential for applications in the life and materials sciences, and discuss the latest advanced concepts and probable future developments.

  19. Image Quality and Radiation Exposure Comparison of a Double High-Pitch Acquisition for Coronary Computed Tomography Angiography Versus Standard Retrospective Spiral Acquisition in Patients With Atrial Fibrillation.

    PubMed

    Prazeres, Carlos Eduardo Elias Dos; Magalhães, Tiago Augusto; de Castro Carneiro, Adriano Camargo; Cury, Roberto Caldeira; de Melo Moreira, Valéria; Bello, Juliana Hiromi Silva Matsumoto; Rochitte, Carlos Eduardo

    The aim of this study was to compare image quality and radiation dose of coronary computed tomography (CT) angiography performed with dual-source CT scanner using 2 different protocols in patients with atrial fibrillation. Forty-seven patients with AF underwent 2 different acquisition protocols: double high-pitch (DHP) spiral acquisition and retrospective spiral acquisition. The image quality was ranked according to a qualitative score by 2 experts: 1, no evident motion; 2, minimal motion not influencing coronary artery luminal evaluation; and 3, motion with impaired luminal evaluation. A third expert solved any disagreement. A total of 732 segments were evaluated. The DHP group (24 patients, 374 segments) showed more segments classified as score 1 than the retrospective spiral acquisition group (71.3% vs 37.4%). Image quality evaluation agreement was high between observers (κ = 0.8). There was significantly lower radiation exposure for the DHP group (3.65 [1.29] vs 23.57 [10.32] mSv). In this original direct comparison, a DHP spiral protocol for coronary CT angiography acquisition in patients with atrial fibrillation resulted in lower radiation exposure and superior image quality compared with conventional spiral retrospective acquisition.

  20. Heart transplant coronary artery disease: Multimodality approach in percutaneous intervention.

    PubMed

    Leite, Luís; Matos, Vítor; Gonçalves, Lino; Silva Marques, João; Jorge, Elisabete; Calisto, João; Antunes, Manuel; Pego, Mariano

    2016-06-01

    Coronary artery disease is the most important cause of late morbidity and mortality after heart transplantation. It is usually an immunologic phenomenon termed cardiac allograft vasculopathy, but can also be the result of donor-transmitted atherosclerosis. Routine surveillance by coronary angiography should be complemented by intracoronary imaging, in order to determine the nature of the coronary lesions, and also by assessment of their functional significance to guide the decision whether to perform percutaneous coronary intervention. We report a case of coronary angiography at five-year follow-up after transplantation, using optical coherence tomography and fractional flow reserve to assess and optimize treatment of coronary disease in this challenging population. Copyright © 2016 Sociedade Portuguesa de Cardiologia. Published by Elsevier España. All rights reserved.

  1. UNDERSTANDING X-RAY STARS:. The Discovery of Binary X-ray Sources

    NASA Astrophysics Data System (ADS)

    Schreier, E. J.; Tananbaum, H.

    2000-09-01

    The discovery of binary X-ray sources with UHURU introduced many new concepts to astronomy. It provided the canonical model which explained X-ray emission from a large class of galactic X-ray sources: it confirmed the existence of collapsed objects as the source of intense X-ray emission; showed that such collapsed objects existed in binary systems, with mass accretion as the energy source for the X-ray emission; and provided compelling evidence for the existence of black holes. This model also provided the basis for explaining the power source of AGNs and QSOs. The process of discovery and interpretation also established X-ray astronomy as an essential sub-discipline of astronomy, beginning its incorporation into the mainstream of astronomy.

  2. Thoracic spine x-ray

    MedlinePlus

    Vertebral radiography; X-ray - spine; Thoracic x-ray; Spine x-ray; Thoracic spine films; Back films ... The test is done in a hospital radiology department or in the health care provider's office. You will lie on the x-ray table in different positions. If the x-ray ...

  3. X-ray binaries

    NASA Technical Reports Server (NTRS)

    1976-01-01

    Satellite X-ray experiments and ground-based programs aimed at observation of X-ray binaries are discussed. Experiments aboard OAO-3, OSO-8, Ariel 5, Uhuru, and Skylab are included along with rocket and ground-based observations. Major topics covered are: Her X-1, Cyg X-3, Cen X-3, Cyg X-1, the transient source A0620-00, other possible X-ray binaries, and plans and prospects for future observational programs.

  4. CAPILLARY NETWORK ALTERATIONS IN X-LINKED RETINOSCHISIS IMAGED ON OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY.

    PubMed

    Romano, Francesco; Arrigo, Alessandro; Chʼng, Soon Wai; Battaglia Parodi, Maurizio; Manitto, Maria Pia; Martina, Elisabetta; Bandello, Francesco; Stanga, Paulo E

    2018-06-05

    To assess foveal and parafoveal vasculature at the superficial capillary plexus, deep capillary plexus, and choriocapillaris of patients with X-linked retinoschisis by means of optical coherence tomography angiography. Six patients with X-linked retinoschisis (12 eyes) and seven healthy controls (14 eyes) were recruited and underwent complete ophthalmologic examination, including best-corrected visual acuity, dilated fundoscopy, and 3 × 3-mm optical coherence tomography angiography macular scans (DRI OCT Triton; Topcon Corp). After segmentation and quality review, optical coherence tomography angiography slabs were imported into ImageJ 1.50 (NIH; Bethesda) and digitally binarized. Quantification of vessel density was performed after foveal avascular zone area measurement and exclusion. Patients were additionally divided into "responders" and "nonresponders" to dorzolamide therapy. Foveal avascular zone area resulted markedly enlarged at the deep capillary plexus (P < 0.001), particularly in nonresponders. Moreover, patients disclosed a significant deep capillary plexus rarefaction, when compared with controls (P: 0.04); however, a subanalysis revealed that this damage was limited to the fovea (P: 0.006). Finally, the enlargement of foveal avascular zone area positively correlated with a decline in best-corrected visual acuity (P: 0.01). Prominent foveal vascular impairment is detectable in the deep capillary plexus of patients with X-linked retinoschisis. Our results correlate with functional outcomes, suggesting a possible vascular role in X-linked retinoschisis clinical manifestations.

  5. Diagnostic Performance of a Novel Coronary CT Angiography Algorithm: Prospective Multicenter Validation of an Intracycle CT Motion Correction Algorithm for Diagnostic Accuracy.

    PubMed

    Andreini, Daniele; Lin, Fay Y; Rizvi, Asim; Cho, Iksung; Heo, Ran; Pontone, Gianluca; Bartorelli, Antonio L; Mushtaq, Saima; Villines, Todd C; Carrascosa, Patricia; Choi, Byoung Wook; Bloom, Stephen; Wei, Han; Xing, Yan; Gebow, Dan; Gransar, Heidi; Chang, Hyuk-Jae; Leipsic, Jonathon; Min, James K

    2018-06-01

    Motion artifact can reduce the diagnostic accuracy of coronary CT angiography (CCTA) for coronary artery disease (CAD). The purpose of this study was to compare the diagnostic performance of an algorithm dedicated to correcting coronary motion artifact with the performance of standard reconstruction methods in a prospective international multicenter study. Patients referred for clinically indicated invasive coronary angiography (ICA) for suspected CAD prospectively underwent an investigational CCTA examination free from heart rate-lowering medications before they underwent ICA. Blinded core laboratory interpretations of motion-corrected and standard reconstructions for obstructive CAD (≥ 50% stenosis) were compared with ICA findings. Segments unevaluable owing to artifact were considered obstructive. The primary endpoint was per-subject diagnostic accuracy of the intracycle motion correction algorithm for obstructive CAD found at ICA. Among 230 patients who underwent CCTA with the motion correction algorithm and standard reconstruction, 92 (40.0%) had obstructive CAD on the basis of ICA findings. At a mean heart rate of 68.0 ± 11.7 beats/min, the motion correction algorithm reduced the number of nondiagnostic scans compared with standard reconstruction (20.4% vs 34.8%; p < 0.001). Diagnostic accuracy for obstructive CAD with the motion correction algorithm (62%; 95% CI, 56-68%) was not significantly different from that of standard reconstruction on a per-subject basis (59%; 95% CI, 53-66%; p = 0.28) but was superior on a per-vessel basis: 77% (95% CI, 74-80%) versus 72% (95% CI, 69-75%) (p = 0.02). The motion correction algorithm was superior in subgroups of patients with severely obstructive (≥ 70%) stenosis, heart rate ≥ 70 beats/min, and vessels in the atrioventricular groove. The motion correction algorithm studied reduces artifacts and improves diagnostic performance for obstructive CAD on a per-vessel basis and in selected subgroups on a per

  6. The prognostic value of CT coronary angiography in patients attending hospital with troponin-negative acute chest pain and inconclusive exercise treadmill tests.

    PubMed

    Mordi, Ify; Tzemos, Nikolaos

    2016-05-01

    Once acute coronary syndrome (ACS) is excluded in patients presenting to hospital with acute chest pain, usual practice is to stratify future risk of adverse cardiovascular events. Commonly this is performed by pre-discharge exercise treadmill testing (ETT). Often however, patients are unable to perform the test for various reasons, or the final result is inconclusive. This potentially could lead to uncertainty and to unnecessary invasive coronary angiography. We wished to evaluate the potential prognostic significance of CT coronary angiography (CTCA) in patients with prior inconclusive ETTs. Two hundred and thirty-two consecutive patients underwent CTCA and calcium scoring following hospital attendance with acute chest pain and following exclusion of ACS. All patients were followed up for a combined primary outcome of death, non-fatal myocardial infarction, and late revascularization. The mean follow-up period was 2.5 ± 0.9 years. The combined primary outcome occurred in 26 patients (11.2%). Calcium score (HR 1.16; 95% CI 1.02-1.31, P = 0.023 per 100 Agatston unit increase), the presence of coronary artery disease (CAD) on CTCA (non-obstructive CAD, HR 4.52; 95% CI 1.30-15.73, P = 0.018; obstructive CAD, HR 17.00; 95% CI 4.60-62.85, P < 0.001), and ≥3 segments with non-calcified plaque (HR 3.30; 95% CI 1.24-8.76, P = 0.017) were significant univariable predictors of the primary outcome. CTCA was the only significant multivariable predictor of adverse outcome. The presence of CAD assessed by CTCA is a strong predictor of adverse events in patients with troponin-negative acute chest pain and could potentially be used as an alternative, non-invasive risk stratifier in patients with inconclusive exercise tests. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  7. Comparison of frequency of calcified versus non-calcified coronary lesions by computed tomographic angiography in patients with stable versus unstable angina pectoris.

    PubMed

    Meijs, Matthijs F L; Meijboom, W Bob; Bots, Michiel L; Kyrzopoulos, Stamatis; Eu, Rick Neoh; Prokop, Mathias; Doevendans, Pieter A; de Feyter, Pim J; Cramer, Maarten J

    2009-08-01

    Computed tomographic coronary angiography (CTCA) can noninvasively identify calcified and noncalcified coronary plaques. The aim of this study was to compare the phenotypes of all plaques and of culprit plaques between patients with unstable angina pectoris (UAP) and those with stable angina pectoris (SAP), because plaque characteristics may differ between these patients. In 110 patients with UAP and 189 with SAP from a multicenter study comparing 64-slice CTCA with conventional coronary angiography, the number and phenotypes (noncalcified, mixed, and calcified) of coronary plaques were compared. In a subanalysis in 50 patients with UAP and 64 with SAP, culprit plaque characteristics, including culprit plaque cross-sectional area relative to total vessel cross-sectional area, culprit plaque length, remodeling index, and spotty calcification, were determined. Odds ratios for the presence of UAP, adjusted for clinical variables and the total number of plaques, were calculated for plaque characteristics on CTCA. Although the number of plaques was similar for patients with UAP and those with SAP, plaques in patients with UAP were more frequently noncalcified than in patients with SAP. The odds ratio for UAP was 1.3 (95% confidence interval [CI] 1.1 to 1.5) per noncalcified plaque. In the culprit plaque subanalysis, odds ratios for UAP were 0.99 (95% CI 0.96 to 1.01) per millimeter culprit plaque length, 2.7 (95% CI 1.2 to 6.4) for noncalcified culprit plaque, and 1.06 (95% CI 0.99 to 1.13) per percentage relative culprit plaque cross-sectional area. No significant relation was found between remodeling index or spotty calcification and UAP. In conclusion, noncalcified plaques and large noncalcified culprit plaques are more frequently found in patients with UAP than in those with SAP.

  8. Skull x-ray

    MedlinePlus

    X-ray - head; X-ray - skull; Skull radiography; Head x-ray ... Chernecky CC, Berger BJ. Radiography of skull, chest, and cervical spine - diagnostic. In: Chernecky CC, Berger BJ, eds. Laboratory Tests and Diagnostic Procedures . 6th ed. ...

  9. Full-field transmission x-ray imaging with confocal polycapillary x-ray optics

    PubMed Central

    Sun, Tianxi; MacDonald, C. A.

    2013-01-01

    A transmission x-ray imaging setup based on a confocal combination of a polycapillary focusing x-ray optic followed by a polycapillary collimating x-ray optic was designed and demonstrated to have good resolution, better than the unmagnified pixel size and unlimited by the x-ray tube spot size. This imaging setup has potential application in x-ray imaging for small samples, for example, for histology specimens. PMID:23460760

  10. X-ray generator

    DOEpatents

    Dawson, John M.

    1976-01-01

    Apparatus and method for producing coherent secondary x-rays that are controlled as to direction by illuminating a mixture of high z and low z gases with an intense burst of primary x-rays. The primary x-rays are produced with a laser activated plasma, and these x-rays strip off the electrons of the high z atoms in the lasing medium, while the low z atoms retain their electrons. The neutral atoms transfer electrons to highly excited states of the highly striped high z ions giving an inverted population which produces the desired coherent x-rays. In one embodiment, a laser, light beam provides a laser spark that produces the intense burst of coherent x-rays that illuminates the mixture of high z and low z gases, whereby the high z atoms are stripped while the low z ones are not, giving the desired mixture of highly ionized and neutral atoms. To this end, the laser spark is produced by injecting a laser light beam, or a plurality of beams, into a first gas in a cylindrical container having an adjacent second gas layer co-axial therewith, the laser producing a plasma and the intense primary x-rays in the first gas, and the second gas containing the high and low atomic number elements for receiving the primary x-rays, whereupon the secondary x-rays are produced therein by stripping desired ions in a neutral gas and transfer of electrons to highly excited states of the stripped ions from the unionized atoms. Means for magnetically confining and stabilizing the plasma are disclosed for controlling the direction of the x-rays.

  11. Nonrigid Image Registration in Digital Subtraction Angiography Using Multilevel B-Spline

    PubMed Central

    2013-01-01

    We address the problem of motion artifact reduction in digital subtraction angiography (DSA) using image registration techniques. Most of registration algorithms proposed for application in DSA, have been designed for peripheral and cerebral angiography images in which we mainly deal with global rigid motions. These algorithms did not yield good results when applied to coronary angiography images because of complex nonrigid motions that exist in this type of angiography images. Multiresolution and iterative algorithms are proposed to cope with this problem, but these algorithms are associated with high computational cost which makes them not acceptable for real-time clinical applications. In this paper we propose a nonrigid image registration algorithm for coronary angiography images that is significantly faster than multiresolution and iterative blocking methods and outperforms competing algorithms evaluated on the same data sets. This algorithm is based on a sparse set of matched feature point pairs and the elastic registration is performed by means of multilevel B-spline image warping. Experimental results with several clinical data sets demonstrate the effectiveness of our approach. PMID:23971026

  12. Feasibility of Selective Catheter-Directed Coronary Computed Tomography Angiography Using Ultralow-Dose Intracoronary Contrast Injection in a Swine Model.

    PubMed

    Hong, Youngtaek; Shin, Sanghoon; Park, Hyung-Bok; Lee, Byoung Kwon; Arsanjani, Reza; ó Hartaigh, Bríain; Ha, Seongmin; Jang, Yeonggul; Jeon, Byunghwan; Jung, Sunghee; Park, Se-Il; Sung, Ji Min; Shim, Hackjoon; Chang, Hyuk-Jae

    2015-07-01

    Selective catheter-directed intracoronary contrast injected coronary computed tomography angiography (selective CCTA) has recently been introduced for on-site evaluation of coronary artery disease during coronary artery catheterization. In this study, we aimed to develop a feasible protocol for selective CCTA using ultralow-dose contrast medium as compared with conventional intravenous CCTA (IV CCTA). A novel combined system incorporating coronary angiography and a 320-detector row computed tomographic scanner was used to study 4 swine (35-40 kg) under animal institutional review board approval. A selective CCTA scan was simultaneously performed with an injection of 13.13 mgI/mL of modulated contrast medium at multiple different injection rates including 2, 3, and 4 mL/s and different total injection volumes of either 20 or 30 mL. Intravenous CCTA was performed with 60 mL of contrast medium, followed by 30 mL of saline chaser at 5 mL/s. Coronary mean and peak intensity, transluminal attenuation gradient, as well as 3-dimensional maximum intensity projections were obtained. Attenuation values (mean ± standard error, in Hounsfield units [HUs]) of selective CCTA for the left anterior descending (LAD) and right coronary artery (RCA) using the various combinations of injection rates and total injection volumes were as follows: 20 mL at 2 mL/s (LAD, 270.3 ± 20.4 HU; RCA, 322.6 ± 7.4 HU), 20 mL at 3 mL/s (LAD, 262.9 ± 20.4 HU; RCA, 264.7 ± 7.4 HU), 30 mL at 3 mL/s (LAD, 276.8 ± 20.4 HU; RCA, 274.0 ± 7.4 HU), 20 mL at 4 mL/s (LAD, 268.0 ± 20.4 HU; RCA, 277.7 ± 7.4 HU), and 30 mL at 4 mL/s (LAD, 251.3 ± 20.4 HU; RCA, 334.7 ± 7.4 HU). The representative protocol of the selective CCTA studies produced results within the optimal enhancement range (approximately 250-350 HU) for all segments, and comparison of transluminal attenuation gradient data with selective CCTA and IV CCTA studies demonstrated that the former method was more homogenous (-1.5245 and -1.7558 for

  13. Spontaneous Coronary Dissection: “Live Flash” Optical Coherence Tomography Guided Angioplasty

    PubMed Central

    Bento, Angela Pimenta; Fernandes, Renato Gil dos Santos Pinto; Neves, David Cintra Henriques Silva; Patrício, Lino Manuel Ribeiro; de Aguiar, José Eduardo Chambel

    2016-01-01

    Optical Coherence tomography (OCT) is a light-based imaging modality which shows tremendous potential in the setting of coronary imaging. Spontaneous coronary artery dissection (SCAD) is an infrequent cause of acute coronary syndrome (ACS). The diagnosis of SCAD is made mainly with invasive coronary angiography, although adjunctive imaging modalities such as computed tomography angiography, IVUS, and OCT may increase the diagnostic yield. The authors describe a clinical case of a young woman admitted with the diagnosis of ACS. The ACS was caused by SCAD detected in the coronary angiography and the angioplasty was guided by OCT. OCT use in the setting of SCAD has been already described and the true innovation in this case was this unique use of OCT. The guidance of angioplasty with live and short images was very useful as it allowed clearly identifying the position of the guidewires at any given moment without the use of prohibitive amounts of contrast. PMID:26989520

  14. X-ray lithography masking

    NASA Technical Reports Server (NTRS)

    Smith, Henry I. (Inventor); Lim, Michael (Inventor); Carter, James (Inventor); Schattenburg, Mark (Inventor)

    1998-01-01

    X-ray masking apparatus includes a frame having a supporting rim surrounding an x-ray transparent region, a thin membrane of hard inorganic x-ray transparent material attached at its periphery to the supporting rim covering the x-ray transparent region and a layer of x-ray opaque material on the thin membrane inside the x-ray transparent region arranged in a pattern to selectively transmit x-ray energy entering the x-ray transparent region through the membrane to a predetermined image plane separated from the layer by the thin membrane. A method of making the masking apparatus includes depositing back and front layers of hard inorganic x-ray transparent material on front and back surfaces of a substrate, depositing back and front layers of reinforcing material on the back and front layers, respectively, of the hard inorganic x-ray transparent material, removing the material including at least a portion of the substrate and the back layers of an inside region adjacent to the front layer of hard inorganic x-ray transparent material, removing a portion of the front layer of reinforcing material opposite the inside region to expose the surface of the front layer of hard inorganic x-ray transparent material separated from the inside region by the latter front layer, and depositing a layer of x-ray opaque material on the surface of the latter front layer adjacent to the inside region.

  15. Validation of a new UNIX-based quantitative coronary angiographic system for the measurement of coronary artery lesions.

    PubMed

    Bell, M R; Britson, P J; Chu, A; Holmes, D R; Bresnahan, J F; Schwartz, R S

    1997-01-01

    We describe a method of validation of computerized quantitative coronary arteriography and report the results of a new UNIX-based quantitative coronary arteriography software program developed for rapid on-line (digital) and off-line (digital or cinefilm) analysis. The UNIX operating system is widely available in computer systems using very fast processors and has excellent graphics capabilities. The system is potentially compatible with any cardiac digital x-ray system for on-line analysis and has been designed to incorporate an integrated database, have on-line and immediate recall capabilities, and provide digital access to all data. The accuracy (mean signed differences of the observed minus the true dimensions) and precision (pooled standard deviations of the measurements) of the program were determined x-ray vessel phantoms. Intra- and interobserver variabilities were assessed from in vivo studies during routine clinical coronary arteriography. Precision from the x-ray phantom studies (6-In. field of view) for digital images was 0.066 mm and for digitized cine images was 0.060 mm. Accuracy was 0.076 mm (overestimation) for digital images compared to 0.008 mm for digitized cine images. Diagnostic coronary catheters were also used for calibration; accuracy.varied according to size of catheter and whether or not they were filled with iodinated contrast. Intra- and interobserver variabilities were excellent and indicated that coronary lesion measurements were relatively user-independent. Thus, this easy to use and very fast UNIX based program appears to be robust with optimal accuracy and precision for clinical and research applications.

  16. Sinus x-ray

    MedlinePlus

    Paranasal sinus radiography; X-ray - sinuses ... sinus x-ray is taken in a hospital radiology department. Or the x-ray may be taken ... Brown J, Rout J. ENT, neck, and dental radiology. In: Adam A, Dixon AK, Gillard JH, Schaefer- ...

  17. X-Ray Data Booklet

    Science.gov Websites

    X-RAY DATA BOOKLET Center for X-ray Optics and Advanced Light Source Lawrence Berkeley National Laboratory Introduction X-Ray Properties of Elements Electron Binding Energies X-Ray Energy Emission Energies Table of X-Ray Properties Synchrotron Radiation Characteristics of Synchrotron Radiation History of X

  18. Gender differences in health-related quality of life in patients undergoing coronary angiography.

    PubMed

    Gijsberts, Crystel M; Agostoni, Pierfrancesco; Hoefer, Imo E; Asselbergs, Folkert W; Pasterkamp, Gerard; Nathoe, Hendrik; Appelman, Yolande E; de Kleijn, Dominique P V; den Ruijter, Hester M

    2015-01-01

    Health-related quality of life (HRQOL) reflects the general well-being of individuals. In patients with coronary artery disease (CAD), HRQOL is compromised. Female patients with CAD have been reported to have lower HRQOL. In this study, we investigate gender differences in HRQOL and in associations of patient characteristics with HRQOL in patients with coronary angiography (CAG). We cross-sectionally analysed patients from the Utrecht Coronary Biobank undergoing CAG. All patients filled in an HRQOL questionnaire (RAND-36 and EuroQoL) on inclusion. RAND-36 and EuroQoL HRQOL measures were compared between the genders across indications for CAG, CAD severity and treatment of CAD. RAND-36 HRQOL measures were compared with the general Dutch population. Additionally, we assessed interactions of gender with patient characteristics in their association with HRQOL (EuroQoL). We included 1421 patients (1020 men and 401 women) with a mean age of 65 in our analysis. Women reported lower HRQOL measures than men (mean EuroQoL self-rated health grade 6.84±1.49 in men, 6.46±1.40 in women, p<0.001). The reduction in RAND-36 HRQOL as compared with the general Dutch population was larger in women than in men. From regression analysis, we found that diabetes, a history of cardiovascular disease and symptoms of shortness of breath determined HRQOL (EuroQoL) more strongly in men than in women. Women reported lower HRQOL than men throughout all indications for CAG and regardless of CAD severity or treatment. As compared with the general population, the reduction in HRQOL was more extreme in women than in men. Evident gender differences were found in determinants of HRQOL in patients undergoing CAG, which deserve attention in future research. NCT02304744 (clinicaltrials.gov).

  19. Recent X-ray Variability of Eta Car Approaching The X-ray Eclipse

    NASA Technical Reports Server (NTRS)

    Corcoran, M.; Swank, J. H.; Ishibashi, K.; Gull, T.; Humphreys, R.; Damineli, A.; Walborn, N.; Hillier, D. J.; Davidson, K.; White, S. M.

    2002-01-01

    We discuss recent X-ray spectral variability of the supermassive star Eta Car in the interval since the last X-ray eclipse in 1998. We concentrate on the interval just prior to the next X-ray eclipse which is expected to occur in June 2003. We compare the X-ray behavior during the 2001-2003 cycle with the previous cycle (1996-1998) and note similarities and differences in the temporal X-ray behavior. We also compare a recent X-ray observation of Eta Car obtained with the Chandra high energy transmission grating in October 2002 with an earlier observation from Nov 2002, and interpret these results in terms of the proposed colliding wind binary model for the star. In addition we discuss planned observations for the upcoming X-ray eclipse.

  20. Large area soft x-ray collimator to facilitate x-ray optics testing

    NASA Technical Reports Server (NTRS)

    Espy, Samuel L.

    1994-01-01

    The first objective of this program is to design a nested conical foil x-ray optic which will collimate x-rays diverging from a point source. The collimator could then be employed in a small, inexpensive x-ray test stand which would be used to test various x-ray optics and detector systems. The second objective is to demonstrate the fabrication of the x-ray reflectors for this optic using lacquer-smoothing and zero-stress electroforming techniques.

  1. Development of x-ray laminography under an x-ray microscopic condition

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoshino, Masato; Uesugi, Kentaro; Takeuchi, Akihisa

    2011-07-15

    An x-ray laminography system under an x-ray microscopic condition was developed to obtain a three-dimensional structure of laterally-extended planar objects which were difficult to observe by x-ray tomography. An x-ray laminography technique was introduced to an x-ray transmission microscope with zone plate optics. Three prototype sample holders were evaluated for x-ray imaging laminography. Layered copper grid sheets were imaged as a laminated sample. Diatomite powder on a silicon nitride membrane was measured to confirm the applicability of this method to non-planar micro-specimens placed on the membrane. The three-dimensional information of diatom shells on the membrane was obtained at a spatialmore » resolution of sub-micron. Images of biological cells on the membrane were also obtained by using a Zernike phase contrast technique.« less

  2. Prediction model to estimate presence of coronary artery disease: retrospective pooled analysis of existing cohorts

    PubMed Central

    Genders, Tessa S S; Steyerberg, Ewout W; Nieman, Koen; Galema, Tjebbe W; Mollet, Nico R; de Feyter, Pim J; Krestin, Gabriel P; Alkadhi, Hatem; Leschka, Sebastian; Desbiolles, Lotus; Meijs, Matthijs F L; Cramer, Maarten J; Knuuti, Juhani; Kajander, Sami; Bogaert, Jan; Goetschalckx, Kaatje; Cademartiri, Filippo; Maffei, Erica; Martini, Chiara; Seitun, Sara; Aldrovandi, Annachiara; Wildermuth, Simon; Stinn, Björn; Fornaro, Jürgen; Feuchtner, Gudrun; De Zordo, Tobias; Auer, Thomas; Plank, Fabian; Friedrich, Guy; Pugliese, Francesca; Petersen, Steffen E; Davies, L Ceri; Schoepf, U Joseph; Rowe, Garrett W; van Mieghem, Carlos A G; van Driessche, Luc; Sinitsyn, Valentin; Gopalan, Deepa; Nikolaou, Konstantin; Bamberg, Fabian; Cury, Ricardo C; Battle, Juan; Maurovich-Horvat, Pál; Bartykowszki, Andrea; Merkely, Bela; Becker, Dávid; Hadamitzky, Martin; Hausleiter, Jörg; Dewey, Marc; Zimmermann, Elke; Laule, Michael

    2012-01-01

    Objectives To develop prediction models that better estimate the pretest probability of coronary artery disease in low prevalence populations. Design Retrospective pooled analysis of individual patient data. Setting 18 hospitals in Europe and the United States. Participants Patients with stable chest pain without evidence for previous coronary artery disease, if they were referred for computed tomography (CT) based coronary angiography or catheter based coronary angiography (indicated as low and high prevalence settings, respectively). Main outcome measures Obstructive coronary artery disease (≥50% diameter stenosis in at least one vessel found on catheter based coronary angiography). Multiple imputation accounted for missing predictors and outcomes, exploiting strong correlation between the two angiography procedures. Predictive models included a basic model (age, sex, symptoms, and setting), clinical model (basic model factors and diabetes, hypertension, dyslipidaemia, and smoking), and extended model (clinical model factors and use of the CT based coronary calcium score). We assessed discrimination (c statistic), calibration, and continuous net reclassification improvement by cross validation for the four largest low prevalence datasets separately and the smaller remaining low prevalence datasets combined. Results We included 5677 patients (3283 men, 2394 women), of whom 1634 had obstructive coronary artery disease found on catheter based coronary angiography. All potential predictors were significantly associated with the presence of disease in univariable and multivariable analyses. The clinical model improved the prediction, compared with the basic model (cross validated c statistic improvement from 0.77 to 0.79, net reclassification improvement 35%); the coronary calcium score in the extended model was a major predictor (0.79 to 0.88, 102%). Calibration for low prevalence datasets was satisfactory. Conclusions Updated prediction models including age, sex

  3. Laser plasma x-ray source for ultrafast time-resolved x-ray absorption spectroscopy

    DOE PAGES

    Miaja-Avila, L.; O'Neil, G. C.; Uhlig, J.; ...

    2015-03-02

    We describe a laser-driven x-ray plasma source designed for ultrafast x-ray absorption spectroscopy. The source is comprised of a 1 kHz, 20 W, femtosecond pulsed infrared laser and a water target. We present the x-ray spectra as a function of laser energy and pulse duration. Additionally, we investigate the plasma temperature and photon flux as we vary the laser energy. We obtain a 75 μm FWHM x-ray spot size, containing ~10 6 photons/s, by focusing the produced x-rays with a polycapillary optic. Since the acquisition of x-ray absorption spectra requires the averaging of measurements from >10 7 laser pulses, wemore » also present data on the source stability, including single pulse measurements of the x-ray yield and the x-ray spectral shape. In single pulse measurements, the x-ray flux has a measured standard deviation of 8%, where the laser pointing is the main cause of variability. Further, we show that the variability in x-ray spectral shape from single pulses is low, thus justifying the combining of x-rays obtained from different laser pulses into a single spectrum. Finally, we show a static x-ray absorption spectrum of a ferrioxalate solution as detected by a microcalorimeter array. Altogether, our results demonstrate that this water-jet based plasma source is a suitable candidate for laboratory-based time-resolved x-ray absorption spectroscopy experiments.« less

  4. Intact Imaging of Human Heart Structure Using X-ray Phase-Contrast Tomography.

    PubMed

    Kaneko, Yukihiro; Shinohara, Gen; Hoshino, Masato; Morishita, Hiroyuki; Morita, Kiyozo; Oshima, Yoshihiro; Takahashi, Masashi; Yagi, Naoto; Okita, Yutaka; Tsukube, Takuro

    2017-02-01

    Structural examination of human heart specimens at the microscopic level is a prerequisite for understanding congenital heart diseases. It is desirable not to destroy or alter the properties of such specimens because of their scarcity. However, many of the currently available imaging techniques either destroy the specimen through sectioning or alter the chemical and mechanical properties of the specimen through staining and contrast agent injection. As a result, subsequent studies may not be possible. X-ray phase-contrast tomography is an imaging modality for biological soft tissues that does not destroy or alter the properties of the specimen. The feasibility of X-ray phase-contrast tomography for the structural examination of heart specimens was tested using infantile and fetal heart specimens without congenital diseases. X-ray phase-contrast tomography was carried out at the SPring-8 synchrotron radiation facility using the Talbot grating interferometer at the bending magnet beamline BL20B2 to visualize the structure of five non-pretreated whole heart specimens obtained by autopsy. High-resolution, three-dimensional images were obtained for all specimens. The images clearly showed the myocardial structure, coronary vessels, and conduction bundle. X-ray phase-contrast tomography allows high-resolution, three-dimensional imaging of human heart specimens. Intact imaging using X-ray phase-contrast tomography can contribute to further structural investigation of heart specimens with congenital heart diseases.

  5. Coronary Computed Tomography Angiography (CTA)

    MedlinePlus

    ... coronary arteries, may also be administered as a tablet or spray underneath your tongue. While lying on ... the scanner at one time such as with MRI. If an intravenous contrast material is used, you ...

  6. Stress-only myocardial perfusion scintigraphy: a prospective study on the accuracy and observer agreement with quantitative coronary angiography as the gold standard.

    PubMed

    Ejlersen, June A; May, Ole; Mortensen, Jesper; Nielsen, Gitte L; Lauridsen, Jeppe F; Allan, Johansen

    2017-11-01

    Patients with normal stress perfusion have an excellent prognosis. Prospective studies on the diagnostic accuracy of stress-only scans with contemporary, independent examinations as gold standards are lacking. A total of 109 patients with typical angina and no previous coronary artery disease underwent a 2-day stress (exercise)/rest, gated, and attenuation-corrected (AC), 99m-technetium-sestamibi perfusion study, followed by invasive coronary angiography. The stress datasets were evaluated twice by four physicians with two different training levels (expert and novice): familiar and unfamiliar with AC. The two experts also made a consensus reading of the integrated stress-rest datasets. The consensus reading and quantitative data from the invasive coronary angiography were applied as reference methods. The sensitivity/specificity were 0.92-1.00/0.73-0.90 (reference: expert consensus reading), 0.93-0.96/0.63-0.82 (reference: ≥1 stenosis>70%), and 0.75-0.88/0.70-0.88 (reference: ≥1 stenosis>50%). The four readers showed a high and fairly equal sensitivity independent of their familiarity with AC. The expert familiar with AC had the highest specificity independent of the reference method. The intraobserver and interobserver agreements on the stress-only readings were good (readers without AC experience) to excellent (readers with AC experience). AC stress-only images yielded a high sensitivity independent of the training level and experience with AC of the nuclear physician, whereas the specificity correlated positively with both. Interobserver and intraobserver agreements tended to be the best for physicians with AC experience.

  7. Diagnostic accuracy of magnetic resonance angiography for detection of coronary artery disease: a systematic review and meta-analysis.

    PubMed

    Di Leo, Giovanni; Fisci, Erica; Secchi, Francesco; Alì, Marco; Ambrogi, Federico; Sconfienza, Luca Maria; Sardanelli, Francesco

    2016-10-01

    To review the diagnostic performance of MR coronary angiography (MRCA) for coronary artery disease (CAD). Two independent reviewers searched on MEDLINE/EMBASE with the following inclusion criteria: 01/01/2000-03/23/2015 publication date; per-patient sensitivity/specificity for >50 % stenosis confirmed by conventional coronary angiography with raw data provided or retrievable; sample size >10. Quality was appraised using QUADAS2. Nine hundred eighteen studies were retrieved, 24 of them, including 1,638 patients, were selected. Using a bivariate model, the pooled sensitivity was 89 % (95 % confidence interval 86-92 %), the pooled specificity 72 % (63-79 %). Meta-regression did not show a significant impact on sensitivity/specificity for both year of publication and disease prevalence (p ≥ 0.114). Sensitivity of contrast-enhanced examinations (95 %, 90-97 %) was higher (p = 0.005) than that of unenhanced examinations (87 %, 83-90 %). Specificity of whole-heart acquisition mode (78 %, 72-84 %) was higher (p = 0.006) than that of targeted mode (57 %, 45-69 %). Specificity at 3 T (83 %, 69-92 %) was higher (p = 0.067) than that at 1.5 T (68 %, 60-76 %). Risk of bias and concerns regarding applicability were low. Sensitivity and specificity of MRCA for CAD were 89 % and 72 %, respectively. A specificity higher than 80 % may be obtained at 3 T. Whole-heart contrast-enhanced protocols should be preferred for a higher diagnostic performance. • MRCA sensitivity and specificity for CAD are below those of CTA. • Contrast administration increased sensitivity to 95 % (90-97 %), comparable with that of CTA. • Whole-heart mode increased specificity to 78 % (72-84 %), comparable with that of CTA. • Specificity at 3 T was borderline-significantly higher (p = 0.067) than at 1.5 T. • Whole-heart contrast-enhanced protocols are the best approach for MRCA.

  8. Panoramic Dental X-Ray

    MedlinePlus

    ... Physician Resources Professions Site Index A-Z Panoramic Dental X-ray Panoramic dental x-ray uses a very small dose of ... x-ray , is a two-dimensional (2-D) dental x-ray examination that captures the entire mouth ...

  9. Quantitative coronary angiography using image recovery techniques for background estimation in unsubtracted images

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wong, Jerry T.; Kamyar, Farzad; Molloi, Sabee

    2007-10-15

    Densitometry measurements have been performed previously using subtracted images. However, digital subtraction angiography (DSA) in coronary angiography is highly susceptible to misregistration artifacts due to the temporal separation of background and target images. Misregistration artifacts due to respiration and patient motion occur frequently, and organ motion is unavoidable. Quantitative densitometric techniques would be more clinically feasible if they could be implemented using unsubtracted images. The goal of this study is to evaluate image recovery techniques for densitometry measurements using unsubtracted images. A humanoid phantom and eight swine (25-35 kg) were used to evaluate the accuracy and precision of the followingmore » image recovery techniques: Local averaging (LA), morphological filtering (MF), linear interpolation (LI), and curvature-driven diffusion image inpainting (CDD). Images of iodinated vessel phantoms placed over the heart of the humanoid phantom or swine were acquired. In addition, coronary angiograms were obtained after power injections of a nonionic iodinated contrast solution in an in vivo swine study. Background signals were estimated and removed with LA, MF, LI, and CDD. Iodine masses in the vessel phantoms were quantified and compared to known amounts. Moreover, the total iodine in left anterior descending arteries was measured and compared with DSA measurements. In the humanoid phantom study, the average root mean square errors associated with quantifying iodine mass using LA and MF were approximately 6% and 9%, respectively. The corresponding average root mean square errors associated with quantifying iodine mass using LI and CDD were both approximately 3%. In the in vivo swine study, the root mean square errors associated with quantifying iodine in the vessel phantoms with LA and MF were approximately 5% and 12%, respectively. The corresponding average root mean square errors using LI and CDD were both 3%. The standard

  10. [Pseudoaneurysm in the vicinity of the ascending aorta caused by contained disruption at the insertion site of a coronary artery bypass graft. A case report].

    PubMed

    Drögemüller, A; Zahn, R; Bergmeier, C; Werling, C; Isgro, F; Senges, J

    1998-08-01

    In this case report a 65-year-old patient came into the emergency ward with acute chest pain after coronary artery bypass graft operation in 1985. On routine chest X-ray in 1995 a mediastinal widening was diagnosed. The chest X-ray in 1997 (Figure 1) showed an increase of the diameter of the known mediastinal widening. Therefore a CT-scan was performed (Figures 2a and 2b). This showed an enhancement of contrast material in a contained structure, without identifying its origin. Therefore a coronary angiography was done. Here, we diagnosed a contained disruption of the aorta at the insertion site of the bypass graft at the right coronary artery. Figure 3a shows leakage of contrast material out of the aorta into the pseudoaneurysm and in Figure 3b this is demonstrated in a schematic drawing. Figure 4a shows supraselective imaging of the pseudoaneurysm, demonstrated in a schematic drawing in Figure 4b. As the chest pain could only be handled by i.v.-medication, betablocker and bed rest we decided to operate. Intra-operatively the diagnosis was confirmed (Figure 5a and 5b). Postoperatively the patient died due to cerebral ischemia. Despite the lethal outcome an operative revision appears even retrospectively justified because of the increasing size of the pseudoaneurysm in addition to new symptoms that were difficult to treat. On the other hand there are no data available in order to estimate the risk of a spontaneous course.

  11. X-ray Spectral Formation In High-mass X-ray Binaries: The Case Of Vela X-1

    NASA Astrophysics Data System (ADS)

    Akiyama, Shizuka; Mauche, C. W.; Liedahl, D. A.; Plewa, T.

    2007-05-01

    We are working to develop improved models of radiatively-driven mass flows in the presence of an X-ray source -- such as in X-ray binaries, cataclysmic variables, and active galactic nuclei -- in order to infer the physical properties that determine the X-ray spectra of such systems. The models integrate a three-dimensional time-dependent hydrodynamics capability (FLASH); a comprehensive and uniform set of atomic data, improved calculations of the line force multiplier that account for X-ray photoionization and non-LTE population kinetics, and X-ray emission-line models appropriate to X-ray photoionized plasmas (HULLAC); and a Monte Carlo radiation transport code that simulates Compton scattering and recombination cascades following photoionization. As a test bed, we have simulated a high-mass X-ray binary with parameters appropriate to Vela X-1. While the orbital and stellar parameters of this system are well constrained, the physics of X-ray spectral formation is less well understood because the canonical analytical wind velocity profile of OB stars does not account for the dynamical and radiative feedback effects due to the rotation of the system and to the irradiation of the stellar wind by X-rays from the neutron star. We discuss the dynamical wind structure of Vela X-1 as determined by the FLASH simulation, where in the binary the X-ray emission features originate, and how the spatial and spectral properties of the X-ray emission features are modified by Compton scattering, photoabsorption, and fluorescent emission. This work was performed under the auspices of the U.S. Department of Energy by University of California, Lawrence Livermore National Laboratory under Contract W-7405-Eng-48.

  12. TOPICAL REVIEW: Digital x-ray tomosynthesis: current state of the art and clinical potential

    NASA Astrophysics Data System (ADS)

    Dobbins, James T., III; Godfrey, Devon J.

    2003-10-01

    Digital x-ray tomosynthesis is a technique for producing slice images using conventional x-ray systems. It is a refinement of conventional geometric tomography, which has been known since the 1930s. In conventional geometric tomography, the x-ray tube and image receptor move in synchrony on opposite sides of the patient to produce a plane of structures in sharp focus at the plane containing the fulcrum of the motion; all other structures above and below the fulcrum plane are blurred and thus less visible in the resulting image. Tomosynthesis improves upon conventional geometric tomography in that it allows an arbitrary number of in-focus planes to be generated retrospectively from a sequence of projection radiographs that are acquired during a single motion of the x-ray tube. By shifting and adding these projection radiographs, specific planes may be reconstructed. This topical review describes the various reconstruction algorithms used to produce tomosynthesis images, as well as approaches used to minimize the residual blur from out-of-plane structures. Historical background and mathematical details are given for the various approaches described. Approaches for optimizing the tomosynthesis image are given. Applications of tomosynthesis to various clinical tasks, including angiography, chest imaging, mammography, dental imaging and orthopaedic imaging, are also described.

  13. X-ray beam finder

    DOEpatents

    Gilbert, H.W.

    1983-06-16

    An X-ray beam finder for locating a focal spot of an X-ray tube includes a mass of X-ray opaque material having first and second axially-aligned, parallel-opposed faces connected by a plurality of substantially identical parallel holes perpendicular to the faces and a film holder for holding X-ray sensitive film tightly against one face while the other face is placed in contact with the window of an X-ray head.

  14. X-ray and gamma ray astronomy detectors

    NASA Technical Reports Server (NTRS)

    Decher, Rudolf; Ramsey, Brian D.; Austin, Robert

    1994-01-01

    X-ray and gamma ray astronomy was made possible by the advent of space flight. Discovery and early observations of celestial x-rays and gamma rays, dating back almost 40 years, were first done with high altitude rockets, followed by Earth-orbiting satellites> once it became possible to carry detectors above the Earth's atmosphere, a new view of the universe in the high-energy part of the electromagnetic spectrum evolved. Many of the detector concepts used for x-ray and gamma ray astronomy were derived from radiation measuring instruments used in atomic physics, nuclear physics, and other fields. However, these instruments, when used in x-ray and gamma ray astronomy, have to meet unique and demanding requirements related to their operation in space and the need to detect and measure extremely weak radiation fluxes from celestial x-ray and gamma ray sources. Their design for x-ray and gamma ray astronomy has, therefore, become a rather specialized and rapidly advancing field in which improved sensitivity, higher energy and spatial resolution, wider spectral coverage, and enhanced imaging capabilities are all sought. This text is intended as an introduction to x-ray and gamma ray astronomy instruments. It provides an overview of detector design and technology and is aimed at scientists, engineers, and technical personnel and managers associated with this field. The discussion is limited to basic principles and design concepts and provides examples of applications in past, present, and future space flight missions.

  15. X-ray imaging crystal spectrometer for extended X-ray sources

    DOEpatents

    Bitter, Manfred L.; Fraenkel, Ben; Gorman, James L.; Hill, Kenneth W.; Roquemore, A. Lane; Stodiek, Wolfgang; von Goeler, Schweickhard E.

    2001-01-01

    Spherically or toroidally curved, double focusing crystals are used in a spectrometer for X-ray diagnostics of an extended X-ray source such as a hot plasma produced in a tokomak fusion experiment to provide spatially and temporally resolved data on plasma parameters using the imaging properties for Bragg angles near 45. For a Bragg angle of 45.degree., the spherical crystal focuses a bundle of near parallel X-rays (the cross section of which is determined by the cross section of the crystal) from the plasma to a point on a detector, with parallel rays inclined to the main plain of diffraction focused to different points on the detector. Thus, it is possible to radially image the plasma X-ray emission in different wavelengths simultaneously with a single crystal.

  16. X-ray lithography source

    DOEpatents

    Piestrup, M.A.; Boyers, D.G.; Pincus, C.

    1991-12-31

    A high-intensity, inexpensive X-ray source for X-ray lithography for the production of integrated circuits is disclosed. Foil stacks are bombarded with a high-energy electron beam of 25 to 250 MeV to produce a flux of soft X-rays of 500 eV to 3 keV. Methods of increasing the total X-ray power and making the cross section of the X-ray beam uniform are described. Methods of obtaining the desired X-ray-beam field size, optimum frequency spectrum and eliminating the neutron flux are all described. A method of obtaining a plurality of station operation is also described which makes the process more efficient and economical. The satisfying of these issues makes transition radiation an excellent moderate-priced X-ray source for lithography. 26 figures.

  17. X-ray lithography source

    DOEpatents

    Piestrup, Melvin A.; Boyers, David G.; Pincus, Cary

    1991-01-01

    A high-intensity, inexpensive X-ray source for X-ray lithography for the production of integrated circuits. Foil stacks are bombarded with a high-energy electron beam of 25 to 250 MeV to produce a flux of soft X-rays of 500 eV to 3 keV. Methods of increasing the total X-ray power and making the cross section of the X-ray beam uniform are described. Methods of obtaining the desired X-ray-beam field size, optimum frequency spectrum and elminating the neutron flux are all described. A method of obtaining a plurality of station operation is also described which makes the process more efficient and economical. The satisfying of these issues makes transition radiation an exellent moderate-priced X-ray source for lithography.

  18. Coronary artery dimensions in normal Indians.

    PubMed

    Raut, Barendra Kumar; Patil, Vijaysinh Namdeo; Cherian, George

    Diameter of coronary artery is an important predictor of outcome after percutaneous coronary interventions and coronary artery bypass graft surgery. There is very limited data available about coronary artery dimensions in an Indian population. To study the normal dimensions of the coronary artery segments in Indians without coronary artery disease by using quantitative coronary angiography and also to compare the dimensions in Indians with Western. 229 patients who have undergone coronary angiography with entirely normal coronary angiogram were included in our study. This study showed the diameter of vessels in males and females when taken together the left main was larger in size followed by proximal LAD, proximal RCA & proximal LCX respectively (4.08±0.44mm, 3.27±0.23mm, 3.20±0.37mm, 2.97±0.37mm).When the vessel diameter was indexed to body surface area there was no statistical difference between male and female (p value>0.05). The computed value of proximal coronary artery diameter unadjusted for individual body surface area, when compared to Caucasians showed that Caucasians have larger coronary artery dimensions than Indians. But when the proximal vessel diameter was indexed to body surface area there was no statistical significant difference between Indians and Caucasians (p value>0.05). We found that coronary artery size when indexed to body surface area is not statistically different in Indian males and females and compared to Caucasians. However with a smaller body habitus Indians have smaller coronary arteries. Copyright © 2017. Published by Elsevier B.V.

  19. Bone cartilage imaging with x-ray interferometry using a practical x-ray tube

    NASA Astrophysics Data System (ADS)

    Kido, Kazuhiro; Makifuchi, Chiho; Kiyohara, Junko; Itou, Tsukasa; Honda, Chika; Momose, Atsushi

    2010-04-01

    The purpose of this study was to design an X-ray Talbot-Lau interferometer for the imaging of bone cartilage using a practical X-ray tube and to develop that imaging system for clinical use. Wave-optics simulation was performed to design the interferometer with a practical X-ray tube, a source grating, two X-ray gratings, and an X-ray detector. An imaging system was created based on the results of the simulation. The specifications were as follows: the focal spot size was 0.3 mm of an X-ray tube with a tungsten anode (Toshiba, Tokyo, Japan). The tube voltage was set at 40 kVp with an additive aluminum filter, and the mean energy was 31 keV. The pixel size of the X-ray detector, a Condor 486 (Fairchild Imaging, California, USA), was 15 μm. The second grating was a Ronchi-type grating whose pitch was 5.3 μm. Imaging performance of the system was examined with X-ray doses of 0.5, 3 and 9 mGy so that the bone cartilage of a chicken wing was clearly depicted with X-ray doses of 3 and 9 mGy. This was consistent with the simulation's predictions. The results suggest that X-ray Talbot-Lau interferometry would be a promising tool in detecting soft tissues in the human body such as bone cartilage for the X-ray image diagnosis of rheumatoid arthritis. Further optimization of the system will follow to reduce the X-ray dose for clinical use.

  20. Prognostic Value of Negative Coronary CT Angiography in Severely Obese Patients Prior to Bariatric Surgery: a Follow-Up After 6 Years.

    PubMed

    Messerli, Michael; Maywald, Céline; Wälti, Stephan; Warschkow, René; Wildermuth, Simon; Alkadhi, Hatem; Leschka, Sebastian; Schiesser, Marc

    2017-08-01

    This study aims to determine the long-term prognostic value of coronary CT angiography (CCTA) prior to bariatric surgery in severely obese patients with a body mass index (BMI) ≥35 kg/m 2 . Seventy consecutive patients undergoing cardiac CT for coronary assessment prior to bariatric surgery were prospectively included. Images were analysed for the presence of coronary calcification and for non-obstructive (<50%) or obstructive (>50% stenosis) coronary artery disease (CAD). A median clinical follow-up of 6.1 years in 54 patients was obtained for major adverse cardiovascular events (MACEs), defined as death, non-fatal myocardial infarction or coronary revascularisation. Weight loss and BMI decrease following bariatric surgery were recorded. The median BMI prior to surgery was 46.9 kg/m 2 . The median percentage of excess BMI loss after surgery was 75%. CT showed coronary calcification in 26 (48%) patients, whereas 28 (52%) patients had no calcification. CCTA revealed normal coronaries in 47 (87%) and non-obstructive CAD in 7 (13%) patients. No obstructive CAD was found. All patients successfully underwent bariatric surgery, and no MACE occurred neither perioperatively nor in the follow-up period. The negative predictive value of CCTA was 100% (95% confidence interval of 90.1-100.0%). In severely obese patients, the absence of obstructive CAD in cardiac CT prior to bariatric surgery with subsequently marked weight reduction has strong long-term prognostic implications for ruling out major adverse cardiac events in the postoperative period.

  1. Bandpass x-ray diode and x-ray multiplier detector

    DOEpatents

    Wang, C.L.

    1982-09-27

    An absorption-edge of an x-ray absorption filter and a quantum jump of a photocathode determine the bandpass characteristics of an x-ray diode detector. An anode, which collects the photoelectrons emitted by the photocathode, has enhanced amplification provided by photoelectron-multiplying means which include dynodes or a microchannel-plate electron-multiplier. Suppression of undesired high frequency response for a bandpass x-ray diode is provided by subtracting a signal representative of energies above the passband from a signal representative of the overall response of the bandpass diode.

  2. X-ray astronomical spectroscopy

    NASA Technical Reports Server (NTRS)

    Holt, Stephen S.

    1987-01-01

    The contributions of the Goddard group to the history of X-ray astronomy are numerous and varied. One role that the group has continued to play involves the pursuit of techniques for the measurement and interpretation of the X-ray spectra of cosmic sources. The latest development is the selection of the X-ray microcalorimeter for the Advanced X-ray Astrophysics Facility (AXAF) study payload. This technology is likely to revolutionize the study of cosmic X-ray spectra.

  3. X-Ray

    MedlinePlus

    ... of gray. For some types of X-ray tests, a contrast medium — such as iodine or barium — is introduced into your body to provide greater detail on the images. Why it's done X-ray technology is used to examine many parts of the ...

  4. X-ray luminescence computed tomography using a focused x-ray beam.

    PubMed

    Zhang, Wei; Lun, Michael C; Nguyen, Alex Anh-Tu; Li, Changqing

    2017-11-01

    Due to the low x-ray photon utilization efficiency and low measurement sensitivity of the electron multiplying charge coupled device camera setup, the collimator-based narrow beam x-ray luminescence computed tomography (XLCT) usually requires a long measurement time. We, for the first time, report a focused x-ray beam-based XLCT imaging system with measurements by a single optical fiber bundle and a photomultiplier tube (PMT). An x-ray tube with a polycapillary lens was used to generate a focused x-ray beam whose x-ray photon density is 1200 times larger than a collimated x-ray beam. An optical fiber bundle was employed to collect and deliver the emitted photons on the phantom surface to the PMT. The total measurement time was reduced to 12.5 min. For numerical simulations of both single and six fiber bundle cases, we were able to reconstruct six targets successfully. For the phantom experiment, two targets with an edge-to-edge distance of 0.4 mm and a center-to-center distance of 0.8 mm were successfully reconstructed by the measurement setup with a single fiber bundle and a PMT. (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).

  5. Nonrigid Autofocus Motion Correction for Coronary MR Angiography with a 3D Cones Trajectory

    PubMed Central

    Ingle, R. Reeve; Wu, Holden H.; Addy, Nii Okai; Cheng, Joseph Y.; Yang, Phillip C.; Hu, Bob S.; Nishimura, Dwight G.

    2014-01-01

    Purpose: To implement a nonrigid autofocus motion correction technique to improve respiratory motion correction of free-breathing whole-heart coronary magnetic resonance angiography (CMRA) acquisitions using an image-navigated 3D cones sequence. Methods: 2D image navigators acquired every heartbeat are used to measure superior-inferior, anterior-posterior, and right-left translation of the heart during a free-breathing CMRA scan using a 3D cones readout trajectory. Various tidal respiratory motion patterns are modeled by independently scaling the three measured displacement trajectories. These scaled motion trajectories are used for 3D translational compensation of the acquired data, and a bank of motion-compensated images is reconstructed. From this bank, a gradient entropy focusing metric is used to generate a nonrigid motion-corrected image on a pixel-by-pixel basis. The performance of the autofocus motion correction technique is compared with rigid-body translational correction and no correction in phantom, volunteer, and patient studies. Results: Nonrigid autofocus motion correction yields improved image quality compared to rigid-body-corrected images and uncorrected images. Quantitative vessel sharpness measurements indicate superiority of the proposed technique in 14 out of 15 coronary segments from three patient and two volunteer studies. Conclusion: The proposed technique corrects nonrigid motion artifacts in free-breathing 3D cones acquisitions, improving image quality compared to rigid-body motion correction. PMID:24006292

  6. Validation and comparison of four models to calculate pretest probability of obstructive coronary artery disease in a Chinese population: A coronary computed tomographic angiography study.

    PubMed

    Zhou, Jia; Liu, Yujie; Huang, Lingyu; Tan, Yahang; Li, Xingchen; Zhang, Hong; Ma, Yanhe; Zhang, Ying

    We sought to compare the performance of the updated Diamond-Forrester method (UDFM), Duke clinical score (DCS), Genders clinical model (GCM) and Genders extended model (GEM) in a Chinese population referred to coronary computed tomography angiography (coronary CTA). The reliability of existing models to calculate the pretest proability (PTP) of obstructive coronary artery disease (CAD) have not been fully investigated, especially in a Chinese population. We identified 5743 consecutive patients with suspected stable CAD who underwent coronary calcium scoring (CCS) and coronary CCTA. Obstructive CAD was defined as with the presence of ≥50% diameter stenosis in coronary CTA or unassessable segments due to severe calcification. Area under the receiver operating characteristic curve (AUC), integrated discrimination improvement (IDI), net reclassification improvement (NRI) and Hosmer-Lemeshow goodness-of-fit statistic (H-L χ 2 ) were assessed to validate and compare these models. Overall, 1872 (32%) patients had obstructive CAD and 2467 (43%) had a CCS of 0. GEM demonstrated improved discrimination over the other models through the largest AUC (0.816 for GEM, 0.774 for GCM, 0.772 for DCS and 0.765 for UDFM). UDFM (-0.3255, p < 0.0001), DCS (-0.3149, p < 0.0001) and GCM (-0.2264, p < 0.0001) showed negative IDI compared to GEM. The NRI was significantly higher for GEM than the other models (0.7152, p < 0.0001, 0.5595, p < 0.0001 and 0.3195, p < 0.0001, respectively). All of the four models overestimated the prevalence of obstructive CAD, with unsatisfactory (p < 0.01 for all) calibration for UDFM (H-L χ 2  = 137.82), DCS (H-L χ 2  = 156.70), GCM (H-L χ 2  = 51.17) and GEM (H-L χ 2  = 29.67), respectively. Although GEM was superior for calculating PTP in a Chinese population referred for coronary CTA, developing new models allowing for more accurate and operational estimation are warranted. Copyright © 2017 Society of Cardiovascular Computed

  7. X-ray Observations of Cosmic Ray Acceleration

    NASA Technical Reports Server (NTRS)

    Petre, Robert

    2012-01-01

    Since the discovery of cosmic rays, detection of their sources has remained elusive. A major breakthrough has come through the identification of synchrotron X-rays from the shocks of supernova remnants through imaging and spectroscopic observations by the most recent generation of X-ray observatories. This radiation is most likely produced by electrons accelerated to relativistic energy, and thus has offered the first, albeit indirect, observational evidence that diffusive shock acceleration in supernova remnants produces cosmic rays to TeV energies, possibly as high as the "knee" in the cosmic ray spectrum. X-ray observations have provided information about the maximum energy to which these shOCks accelerate electrons, as well as indirect evidence of proton acceleration. Shock morphologies measured in X-rays have indicated that a substantial fraction of the shock energy can be diverted into particle acceleration. This presentation will summarize what we have learned about cosmic ray acceleration from X-ray observations of supernova remnants over the past two decades.

  8. Incidental finding of single coronary artery in a patient with alcoholic cardiomyopathy presenting as acute heart failure.

    PubMed

    McNair, Patrick; Jones, Erica; Truong, Quynh; Singh, Harsimran

    Single coronary artery is a rare clinical finding. Diagnosis is typically made incidentally after the patient presents with symptoms and undergoes coronary angiography, coronary computed tomography angiography (CTA), or post-mortem during autopsy. Several high-risk features of anomalous coronary arteries have been described in the literature. Our paper describes a case of dilated alcoholic cardiomyopathy presenting as heart failure with diagnostic workup incidentally revealing single coronary artery. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Method for spatially modulating X-ray pulses using MEMS-based X-ray optics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lopez, Daniel; Shenoy, Gopal; Wang, Jin

    A method and apparatus are provided for spatially modulating X-rays or X-ray pulses using microelectromechanical systems (MEMS) based X-ray optics. A torsionally-oscillating MEMS micromirror and a method of leveraging the grazing-angle reflection property are provided to modulate X-ray pulses with a high-degree of controllability.

  10. X-ray monitoring optical elements

    DOEpatents

    Stoupin, Stanislav; Shvydko, Yury; Katsoudas, John; Blank, Vladimir D.; Terentyev, Sergey A.

    2016-12-27

    An X-ray article and method for analyzing hard X-rays which have interacted with a test system. The X-ray article is operative to diffract or otherwise process X-rays from an input X-ray beam which have interacted with the test system and at the same time provide an electrical circuit adapted to collect photoelectrons emitted from an X-ray optical element of the X-ray article to analyze features of the test system.

  11. 64-Slice Computed Tomographic Angiography for the Diagnosis of Intermediate Risk Coronary Artery Disease

    PubMed Central

    2010-01-01

    Executive Summary In July 2009, the Medical Advisory Secretariat (MAS) began work on Non-Invasive Cardiac Imaging Technologies for the Diagnosis of Coronary Artery Disease (CAD), an evidence-based review of the literature surrounding different cardiac imaging modalities to ensure that appropriate technologies are accessed by patients suspected of having CAD. This project came about when the Health Services Branch at the Ministry of Health and Long-Term Care asked MAS to provide an evidentiary platform on effectiveness and cost-effectiveness of non-invasive cardiac imaging modalities. After an initial review of the strategy and consultation with experts, MAS identified five key non-invasive cardiac imaging technologies for the diagnosis of CAD. Evidence-based analyses have been prepared for each of these five imaging modalities: cardiac magnetic resonance imaging, single photon emission computed tomography, 64-slice computed tomographic angiography, stress echocardiography, and stress echocardiography with contrast. For each technology, an economic analysis was also completed (where appropriate). A summary decision analytic model was then developed to encapsulate the data from each of these reports (available on the OHTAC and MAS website). The Non-Invasive Cardiac Imaging Technologies for the Diagnosis of Coronary Artery Disease series is made up of the following reports, which can be publicly accessed at the MAS website at: www.health.gov.on.ca/mas or at www.health.gov.on.ca/english/providers/program/mas/mas_about.html Single Photon Emission Computed Tomography for the Diagnosis of Coronary Artery Disease: An Evidence-Based Analysis Stress Echocardiography for the Diagnosis of Coronary Artery Disease: An Evidence-Based Analysis Stress Echocardiography with Contrast for the Diagnosis of Coronary Artery Disease: An Evidence-Based Analysis 64-Slice Computed Tomographic Angiography for the Diagnosis of Coronary Artery Disease: An Evidence-Based Analysis Cardiac

  12. Optical and X-ray studies of Compact X-ray Binaries in NGC 5904

    NASA Astrophysics Data System (ADS)

    Bhalotia, Vanshree; Beck-Winchatz, Bernhard

    2018-06-01

    Due to their high stellar densities, globular cluster systems trigger various dynamical interactions, such as the formation of compact X-ray binaries. Stellar collisional frequencies have been correlated to the number of X-ray sources detected in various clusters and we hope to measure this correlation for NGC 5904. Optical fluxes of sources from archival HST images of NGC 5904 have been measured using a DOLPHOT PSF photometry in the UV, optical and near-infrared. We developed a data analysis pipeline to process the fluxes of tens of thousands of objects using awk, python and DOLPHOT. We plot color magnitude diagrams in different photometric bands in order to identify outliers that could be X-ray binaries, since they do not evolve the same way as singular stars. Aligning previously measured astrometric data for X-ray sources in NGC 5904 from Chandra with archival astrometric data from HST will filter out the outlier objects that are not X-ray producing, and provide a sample of compact binary systems that are responsible for X-ray emission in NGC 5904. Furthermore, previously measured X-ray fluxes of NGC 5904 from Chandra have also been used to measure the X-ray to optical flux ratio and identify the types of compact X-ray binaries responsible for the X-ray emissions in NGC 5904. We gratefully acknowledge the support from the Illinois Space Grant Consortium.

  13. Coronary Computed Tomography Angiography for Screening in Patients with Diabetes: Can Enhanced Detection of Subclinical Coronary Atherosclerosis Improve Outcome?

    PubMed

    Muhlestein, Joseph Brent; Moreno, Fidela Ll

    2016-11-01

    It is well known that there is a very high risk of cardiovascular complications among diabetic patients. In spite of all efforts at aggressive control of diabetes and its complications, the incidence of cardiovascular morbidity and mortality remains high, including in patients with no prior symptoms, underscoring a possible advantage for appropriate screening of asymptomatic patients for the presence of obstructive coronary artery disease (CAD). In this article, we sought primarily to review the results of studies designed to evaluate a possible role of coronary computed tomography angiography (CCTA) in the screening of asymptomatic diabetic patients for possible obstructive CAD. Our review of current literature indicates that there is still no method of CAD screening identified that has been shown to reduce the cardiovascular risk of asymptomatic diabetic patients. Therefore, the utility and value of screening for CAD in asymptomatic diabetic patients remains controversial. CCTA screening has shown promise and has been demonstrated to predict future risk, but as yet has not demonstrated improvement in the outcomes of these high-risk patients. At our present state of knowledge, aggressive risk factor reduction appears to be the most important primary prevention strategy for all asymptomatic high-risk diabetic patients. However, there remains a great need for better and more sensitive and specific screening methods, as well as more effective treatments that may allow us to more accurately target diabetic patients who really are at high risk. Further large randomized and well-controlled clinical trials may be necessary to determine whether screening for CAD can reduce cardiovascular event rates in patients with diabetes.

  14. Complete Versus Incomplete Angiography Prior to Percutaneous Coronary Intervention in ST-Elevation Myocardial Infarction.

    PubMed

    Stiver, Kevin; Gao, Xu; Shreenivas, Satya; Boudoulas, Konstantinos Dean; Mazzaferri, Ernie; Makki, Nader; Lilly, Scott M

    2017-08-01

    Shorter reperfusion times in ST-elevation myocardial infarction (STEMI) are associated with improved survival. Prehospital strategies have been developed to minimize door-to-balloon (DTB) time, but few strategies within the catheterization laboratory itself have been evaluated. Incomplete angiography (IA) prior to percutaneous coronary intervention (PCI) is undertaken in clinical practice as a means to further reduce DTB time. We sought to determine whether or not those with STEMI who underwent IA prior to PCI had different preprocedural characteristics or post-PCI outcomes. We retrospectively reviewed patients presenting to our institution between March 2013 and December 2015. Clinical, demographic, and angiographic data were reviewed. The frequency, predictors, and outcomes among those who received IA vs complete angiography (CA) prior to PCI were compared with analysis of variance. Two hundred fifty-six patients were identified; 68 patients (26.6%) underwent IA and 188 patients (73.4%) had CA prior to PCI. Patients who received IA were younger, but no other preprocedural factors were predictive of IA. The practice of IA did vary by operator (range, 0%-47%; P<.01). DTB times were shorter in the IA group (28.1 min vs 37.3 min; P<.01). Overall outcomes, including peak troponin values, length of stay, in-hospital mortality, and discharge ejection fraction did not differ between the groups. IA is associated with shorter DTB times, although in this population was not associated with improvements in short-term outcomes.

  15. [Relationship between coronary tortuosity and coronary microvascular disease].

    PubMed

    Wang, Z Y; Wang, Y B; Hao, G Z; Jiang, Y F; Gu, X S; Fan, W Z; Gong, Q; Wang, Q; Fu, X H

    2018-05-24

    Objective: To explore the relationship between coronary tortuosity and coronary microvascular disease (CMVD). Methods: Patients with typical angina symptoms and without serious coronary artery stenosis by coronary angiography were enrolled from June 2014 to December 2016, and CMVD was diagnosed by single photon emission tomography (SPECT). According to the SPECT results, patients were divided to the CMVD group and non-CMVD group. The baseline clinical characteristics, results of coronary angiography were compared between the two groups. The logistic analysis was used to analyze the relationship between coronary tortuosity and CMVD. Result: A total of 117 cases were enrolled, with 69 cases in the CMVD group and 48 cases in the non-CMVD group. No differences were found in gender distribution, age, hypertension, lipid abnormality, hyperuricemia and uses of statins between the two groups (all P >0.05). Incidence of diabetes (78.26%(54/69) vs. 35.42% (17/48) , P <0.05), hs-CRP ((4.29±2.15)mmol/L vs. (2.63±1.20)mmol/L, P <0.001), LDL-C ((2.98±0.96)mmol/L vs. (2.52±0.83)mmol/L, P= 0.008) and homocysteine ((13.7±5.61)mmol/L vs. (11.5±4.38)mmol/L, P= 0.025) levels were higher in the CMVD group than in the non-CMVD group. The data derived from echocardiographic examination were similar between the two groups. The Corrected TIMI frame counts were higher in the CMVD group than in non-CMVD group (LAD: 31.56±4.92 vs. 27.31±3.75, LCX: 29.47±4.18 vs. 26.62±3.19, RCA: 29.09±5.05 vs. 26.24±3.28, all P <0.001). The incidences of coronary atherosclerosis (76.81% (53/69) vs. 27.08% (13/48) , P <0.001) and coronary tortuosity ( (60.87% (42/69) vs. 33.33% (16/48) , P= 0.035) were also higher in the CMVD group than in non-CMVD group. Logistic analysis found that coronary tortuosity ( OR= 6.111, 95% CI 2.707-13.794, P <0.001), diabetes ( OR= 6.565, 95% CI 2.883-14.948, P <0.001) and coronary atherosclerosis ( OR= 8.918, 95% CI 3.822-20.808, P <0.001) were independent risk

  16. Noninvasive Imaging in Coronary Artery Disease

    PubMed Central

    Heo, Ran; Nakazato, Ryo; Kalra, Dan; Min, James K.

    2014-01-01

    Noninvasive cardiac imaging is widely used to evaluate the presence of coronary artery disease. Recently, with improvements in imaging technology, noninvasive imaging has also been used for evaluation of the presence, severity, and prognosis of coronary artery disease. Coronary CT angiography and MRI of coronary arteries provide an anatomical assessment of coronary stenosis, whereas the hemodynamic significance of a coronary artery stenosis can be assessed by stress myocardial perfusion imaging, such as SPECT/PET and stress MRI. For appropriate use of multiple imaging modalities, the strengths and limitations of each modality are discussed in this review. PMID:25234083

  17. Ten-year experience of an invasive cardiology centre with out-of-hospital cardiac arrest patients admitted for urgent coronary angiography.

    PubMed

    Zeliaś, Aleksander; Stępińska, Janina; Andres, Janusz; Trąbka-Zawicki, Aleksander; Sadowski, Jerzy; Żmudka, Krzysztof

    2014-01-01

    The aim of the study was to evaluate survival and neurological function of out-of-hospital cardiac arrest (OHCA) patients admitted for urgent coronary angiography (UCA) with a view to percutaneous coronary intervention (PCI). Hospital records of OHCA patients admitted to an invasive cardiology centre (providing 24 h a day/7 days a week service) in 2000-2010 were reviewed retrospectively, and similar data collected in 2011 were reviewed prospectively. Reports from the pre-hospital phase from emergency medical services (EMS) in Krakow were also analysed. Long-term follow-up data were collected by retrieving records from other hospitals (for patients transferred after UCA/PCI) and by phone calls to patients or their relatives. In 2000-2011, 405 OHCA patients were admitted for UCA/PCI. Most (78%) had ventricular fibrillation (VF) or ventricular tachycardia (VT) as the primary mechanism of cardiac arrest (asystole: 13%, pulseless electrical activity: 3%, unknown: 6%). The mean patient age was 61 (range 20-85) years, and 81% were males. On admission, about 70% of patients were unconscious and 11% were in cardiogenic shock. The mean resuscitation time (time to return of spontaneous circulation [ROSC]) was 26.7 (range 1-126) min. ST-T changes seen in an electrocardiogram recorded after ROSC included ST elevation and depression in 52% of cases, only ST depression in 21% of cases, only ST elevation in 17% of cases, unspecific changes (due to intraventricular conduction disturbances) in 7% of cases, negative T waves in 3% of cases, and no changes in 0.5% of cases. Coronary angiography revealed acute coronary occlusion in 48% of cases, critical coronary stenosis (> 90%) in 26% of cases, other significant coronary lesions (> 50% stenosis) in 15% of cases, and non-significant lesions in 11% of cases. An acute coronary syndrome (ACS) was diagnosed in 82% of patients (75% STEMI, 25% NSTEMI), and other cardiac cause (mostly ischaemic cardiomyopathy) was identified in 13% of

  18. Meta-Analysis of Individual Patient Data of Sodium Bicarbonate and Sodium Chloride for All-Cause Mortality After Coronary Angiography.

    PubMed

    Brown, Jeremiah R; Pearlman, Daniel M; Marshall, Emily J; Alam, Shama S; MacKenzie, Todd A; Recio-Mayoral, Alejandro; Gomes, Vitor O; Kim, Bokyung; Jensen, Lisette O; Mueller, Christian; Maioli, Mauro; Solomon, Richard J

    2016-11-15

    We sought to examine the relation between sodium bicarbonate prophylaxis for contrast-associated nephropathy (CAN) and mortality. We conducted an individual patient data meta-analysis from multiple randomized controlled trials. We obtained individual patient data sets for 7 of 10 eligible trials (2,292 of 2,764 participants). For the remaining 3 trials, time-to-event data were imputed based on follow-up periods described in their original reports. We included all trials that compared periprocedural intravenous sodium bicarbonate to periprocedural intravenous sodium chloride in patients undergoing coronary angiography or other intra-arterial interventions. Included trials were determined by consensus according to predefined eligibility criteria. The primary outcome was all-cause mortality hazard, defined as time from randomization to death. In 10 trials with a total of 2,764 participants, sodium bicarbonate was associated with lower mortality hazard than sodium chloride at 1 year (hazard ratio 0.61, 95% confidence interval [CI] 0.41 to 0.89, p = 0.011). Although periprocedural sodium bicarbonate was associated with a reduction in the incidence of CAN (relative risk 0.75, 95% CI 0.62 to 0.91, p = 0.003), there exists a statistically significant interaction between the effect on mortality and the occurrence of CAN (hazard ratio 5.65, 95% CI 3.58 to 8.92, p <0.001) for up to 1-year mortality. Periprocedural intravenous sodium bicarbonate seems to be associated with a reduction in long-term mortality in patients undergoing coronary angiography or other intra-arterial interventions. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Incremental prognostic value of coronary computed tomography angiography over coronary calcium scoring for major adverse cardiac events in elderly asymptomatic individuals

    PubMed Central

    Han, Donghee; Hartaigh, Bríain Ó; Gransar, Heidi; Lee, Ji Hyun; Rizvi, Asim; Baskaran, Lohendran; Schulman-Marcus, Joshua; Dunning, Allison; Achenbach, Stephan; Al-Mallah, Mouaz H; Berman, Daniel S; Budoff, Matthew J; Cademartiri, Filippo; Maffei, Erica; Callister, Tracy Q; Chinnaiyan, Kavitha; Chow, Benjamin J W; DeLago, Augustin; Hadamitzky, Martin; Hausleiter, Joerg; Kaufmann, Philipp A; Raff, Gilbert; Shaw, Leslee J; Villines, Todd C; Kim, Yong-Jin; Leipsic, Jonathon; Feuchtner, Gudrun; Cury, Ricardo C; Pontone, Gianluca; Andreini, Daniele; Marques, Hugo; Rubinshtein, Ronen; Hindoyan, Niree; Jones, Erica C; Gomez, Millie; Lin, Fay Y; Chang, Hyuk-Jae; Min, James K

    2018-01-01

    Abstract Aims Coronary computed tomography angiography (CCTA) and coronary artery calcium score (CACS) have prognostic value for coronary artery disease (CAD) events beyond traditional risk assessment. Age is a risk factor with very high weight and little is known regarding the incremental value of CCTA over CAC for predicting cardiac events in older adults. Methods and results Of 27 125 individuals undergoing CCTA, a total of 3145 asymptomatic adults were identified. This study sample was categorized according to tertiles of age (cut-off points: 52 and 62 years). CAD severity was classified as 0, 1–49, and ≥50% maximal stenosis in CCTA, and further categorized according to number of vessels ≥50% stenosis. The Framingham 10-year risk score (FRS) and CACS were employed as major covariates. Major adverse cardiovascular events (MACE) were defined as a composite of all-cause death or non-fatal MI. During a median follow-up of 26 months (interquartile range: 18–41 months), 59 (1.9%) MACE occurred. For patients in the top age tertile, CCTA improved discrimination beyond a model included FRS and CACS (C-statistic: 0.75 vs. 0.70, P-value = 0.015). Likewise, the addition of CCTA improved category-free net reclassification (cNRI) of MACE in patients within the highest age tertile (e.g. cNRI = 0.75; proportion of events/non-events reclassified were 50 and 25%, respectively; P-value <0.05, all). CCTA displayed no incremental benefit beyond FRS and CACS for prediction of MACE in the lower age tertiles. Conclusion CCTA provides added prognostic value beyond cardiac risk factors and CACS for the prediction of MACE in asymptomatic older adults. PMID:28977374

  20. Percutaneous Coronary Intervention for a Patient with Left Main Coronary Compression Syndrome.

    PubMed

    Ikegami, Ryutaro; Ozaki, Kazuyuki; Ozawa, Takuya; Hirono, Satoru; Ito, Masahiro; Minamino, Tohru

    2018-05-15

    Left main coronary compression syndrome rarely occurs in patients with severe pulmonary hypertension. A 65-year-old woman with severe pulmonary hypertension due to an atrial septal defect suffered from angina on effort. Cardiac computed-tomography and coronary angiography revealed considerable stenosis of the left main coronary artery (LMA) caused by compression between the dilated main pulmonary artery trunk and the sinus of valsalva. Stenting of the LMA under intravascular ultrasound imaging was effective for the treatment of angina. We herein report the diagnosis and management of this condition with a brief literature review.

  1. Reduction of scatter radiation during transradial percutaneous coronary angiography: a randomized trial using a lead-free radiation shield.

    PubMed

    Politi, Luigi; Biondi-Zoccai, Giuseppe; Nocetti, Luca; Costi, Tiziana; Monopoli, Daniel; Rossi, Rosario; Sgura, Fabio; Modena, Maria Grazia; Sangiorgi, Giuseppe M

    2012-01-01

    Occupational radiation exposure is a growing problem due to the increasing number and complexity of interventional procedures performed. Radial artery access has reduced the number of complications at the price of longer procedure duration. Radpad® scatter protection is a sterile, disposable bismuth-barium radiation shield drape that should be able to decrease the dose of operator radiation during diagnostic and interventional procedures. Such radiation shield has never been tested in a randomized study in humans. Sixty consecutive patients undergoing coronary angiography by radial approach were randomized 1:1 to Radpad use versus no radiation shield protection. The sterile shield was placed around the area of right radial artery sheath insertion and extended medially to the patient trunk. All diagnostic procedures were performed by the same operator to reduce variability in radiation absorption. Radiation exposure was measured blindly using thermoluminescence dosimeters positioned at the operator's chest, left eye, left wrist, and thyroid. Despite similar fluoroscopy time (3.52 ± 2.71 min vs. 3.46 ± 2.77 min, P = 0.898) and total examination dose (50.5 ± 30.7 vs. 45.8 ± 18.0 Gycm(2), P = 0.231), the mean total radiation exposure to the operator was significantly lower when Radpad was utilized (282.8 ± 32.55 μSv vs. 367.8 ± 105.4 μSv, P < 0.0001) corresponding to a 23% total reduction. Moreover, mean radiation exposure was lower with Radpad utilization at all body locations ranging from 13 to 34% reduction. This first-in-men randomized trial demonstrates that Radpad significantly reduces occupational radiation exposure during coronary angiography performed through right radial artery access. Copyright © 2011 Wiley Periodicals, Inc.

  2. Relationship between platelet-to-lymphocyte ratio and coronary slow flow.

    PubMed

    Oylumlu, Muhammed; Doğan, Adnan; Oylumlu, Mustafa; Yıldız, Abdülkadir; Yüksel, Murat; Kayan, Fethullah; Kilit, Celal; Amasyalı, Basri

    2015-05-01

    The coronary slow flow phenomenon (CSFP), which is characterized by delayed distal vessel opacification in the absence of significant epicardial coronary disease, is an angiographic finding. The aim of this study is to investigate the association between platelet-to-lymphocyte ratio (PLR) and coronary blood flow rate. This is a retrospective observational study. It was based on two medical centers. A total of 197 patients undergoing coronary angiography were included in the study, 95 of whom were patients with coronary slow flow without stenosis in coronary angiography and 102 of whom had normal coronary arteries and normal flow. The PLR was higher in the coronary slow flow group compared with the control groups (p=0.001). In the correlation analysis, PLR showed a significant correlation with left anterior descending (LAD) artery thrombolysis in myocardial infarction (TIMI) frame count. After multiple logistic regression, high levels of PLR were independently associated with coronary slow flow, together with hemoglobin. PLR was higher in patients with CSFP, and we also showed that PLR was significantly and independently associated with CSFP.

  3. The Cambridge-Cambridge X-ray Serendipity Survey: I X-ray luminous galaxies

    NASA Technical Reports Server (NTRS)

    Boyle, B. J.; Mcmahon, R. G.; Wilkes, B. J.; Elvis, M.

    1994-01-01

    We report on the first results obtained from a new optical identification program of 123 faint X-ray sources with S(0.5-2 keV) greater than 2 x 10(exp -14) erg/s/sq cm serendipitously detected in ROSAT PSPC pointed observations. We have spectroscopically identified the optical counterparts to more than 100 sources in this survey. Although the majority of the sample (68 objects) are QSO's, we have also identified 12 narrow emission line galaxies which have extreme X-ray luminosities (10(exp 42) less than L(sub X) less than 10(exp 43.5) erg/s). Subsequent spectroscopy reveals them to be a mixture of star-burst galaxies and Seyfert 2 galaxies in approximately equal numbers. Combined with potentially similar objects identified in the Einstein Extended Medium Sensitivity Survey, these X-ray luminous galaxies exhibit a rate of cosmological evolution, L(sub X) varies as (1 + z)(exp 2.5 +/- 1.0), consistent with that derived for X-ray QSO's. This evolution, coupled with the steep slope determined for the faint end of the X-ray luminosity function (Phi(L(sub X)) varies as L(sub X)(exp -1.9)), implies that such objects could comprise 15-35% of the soft (1-2 keV) X-ray background.

  4. Compact X-ray sources: X-rays from self-reflection

    NASA Astrophysics Data System (ADS)

    Mangles, Stuart P. D.

    2012-05-01

    Laser-based particle acceleration offers a way to reduce the size of hard-X-ray sources. Scientists have now developed a simple scheme that produces a bright flash of hard X-rays by using a single laser pulse both to generate and to scatter an electron beam.

  5. Understanding the X-ray spectrum of anomalous X-ray pulsars and soft gamma-ray repeaters

    NASA Astrophysics Data System (ADS)

    Guo, Yan-Jun; Dai, Shi; Li, Zhao-Sheng; Liu, Yuan; Tong, Hao; Xu, Ren-Xin

    2015-04-01

    Hard X-rays above 10 keV are detected from several anomalous X-ray pulsars (AXPs) and soft gamma-ray repeaters (SGRs), and different models have been proposed to explain the physical origin within the frame of either a magnetar model or a fallback disk system. Using data from Suzaku and INTEGRAL, we study the soft and hard X-ray spectra of four AXPs/SGRs: 1RXS J170849-400910, 1E 1547.0-5408, SGR 1806-20 and SGR 0501+4516. It is found that the spectra could be well reproduced by the bulk-motion Comptonization (BMC) process as was first suggested by Trümper et al., showing that the accretion scenario could be compatible with X-ray emission from AXPs/SGRs. Simulated results from the Hard X-ray Modulation Telescope using the BMC model show that the spectra would have discrepancies from the power-law, especially the cutoff at ˜200 keV. Thus future observations will allow researchers to distinguish different models of the hard X-ray emission and will help us understand the nature of AXPs/SGRs. Supported by the National Natural Science Foundation of China.

  6. Use of automatic exposure control in multislice computed tomography of the coronaries: comparison of 16‐slice and 64‐slice scanner data with conventional coronary angiography

    PubMed Central

    Deetjen, Anja; Möllmann, Susanne; Conradi, Guido; Rolf, Andreas; Schmermund, Axel; Hamm, Christian W; Dill, Thorsten

    2007-01-01

    Objective To evaluate the radiation‐dose‐reduction potential of automatic exposure control (AEC) in 16‐slice and 64‐slice multislice computed tomography (MSCT) of the coronary arteries (computed tomography angiography, CTA) in patients. The rapid growth in MSCT CTA emphasises the necessity of adjusting technique factors to reduce radiation dose exposure. Design A retrospective data analysis was performed for 154 patients who had undergone MSCT CTA. Group 1 (n = 56) had undergone 16‐slice MSCT without AEC, and group 2 (n = 51), with AEC. In group 1, invasive coronary angiography (ICA) had been performed in addition. Group 3 (n = 47) had been examined using a 64‐slice scanner (with AEC, without ECG‐triggered tube current modulation). Results In group 1, the mean (SD) effective dose (ED) for MSCT CTA was 9.76 (1.84) mSv and for ICA it was 2.6 (1.27) mSv. In group 2, the mean ED for MSCT CTA was 5.83 (1.73) mSv, which signifies a 42.8% dose reduction for CTA by the use of AEC. In comparison to ICA, MSCT CTA without AEC shows a 3.8‐fold increase in radiation dose, and the radiation dose of CTA with AEC was increased by a factor of 1.9. In group 3, the mean ED for MSCT CTA was 13.58 (2.80) mSV. Conclusions This is the first study to show the significant dose‐reduction potential (42.8%) of AEC in MSCT CTA in patients. This relatively new technique can be used to optimise the radiation dose levels in MSCT CTA. PMID:17395667

  7. Anomalous origin of right coronary artery from left coronary sinus.

    PubMed

    Hamzeh, Gadah; Crespo, Alex; Estarán, Rafael; Rodríguez, Miguel A; Voces, Roberto; Aramendi, José I

    2008-08-01

    Anomalous aortic origin of the coronary arteries is uncommon but clinically significant. Manifestations vary from asymptomatic patients to those who present with angina pectoris, myocardial infarction, heart failure, syncope, arrhythmias, and sudden death. We describe 4 patients, aged 34 to 59 years, who were diagnosed with right coronary artery arising from the left sinus of Valsalva, confirmed by coronary angiography, which was surgically repaired. Three patients presented dyspnea and angina, and one with acute myocardial infarction. At operation, the right coronary artery was dissected at the take-off from the intramural course, and reimplanted into the right sinus of Valsalva. There was no mortality. One patient had associated coronary artery disease that required stent placement postoperatively. This reimplantation technique provides a good physiological and anatomical repair, eliminates a slit-like ostium, avoids compression of the coronary artery between the aorta and the pulmonary artery, and gives superior results to coronary artery bypass grafting or the unroofing technique.

  8. X-ray crystallography

    NASA Technical Reports Server (NTRS)

    2001-01-01

    X-rays diffracted from a well-ordered protein crystal create sharp patterns of scattered light on film. A computer can use these patterns to generate a model of a protein molecule. To analyze the selected crystal, an X-ray crystallographer shines X-rays through the crystal. Unlike a single dental X-ray, which produces a shadow image of a tooth, these X-rays have to be taken many times from different angles to produce a pattern from the scattered light, a map of the intensity of the X-rays after they diffract through the crystal. The X-rays bounce off the electron clouds that form the outer structure of each atom. A flawed crystal will yield a blurry pattern; a well-ordered protein crystal yields a series of sharp diffraction patterns. From these patterns, researchers build an electron density map. With powerful computers and a lot of calculations, scientists can use the electron density patterns to determine the structure of the protein and make a computer-generated model of the structure. The models let researchers improve their understanding of how the protein functions. They also allow scientists to look for receptor sites and active areas that control a protein's function and role in the progress of diseases. From there, pharmaceutical researchers can design molecules that fit the active site, much like a key and lock, so that the protein is locked without affecting the rest of the body. This is called structure-based drug design.

  9. The Advanced X-Ray Astrophysics Facility. Observing the Universe in X-Rays

    NASA Technical Reports Server (NTRS)

    Neal, V.

    1984-01-01

    An overview of the Advanced X ray Astronophysics Facility (AXAF) program is presented. Beginning with a brief introduction to X ray astrophysics, the AXAF observatory is described including the onboard instrumentation and system capabilities. Possible X ray sources suitable for AXAF observation are identified and defined.

  10. A multicentre, randomized, double-blind placebo-controlled trial evaluating rosiglitazone for the prevention of atherosclerosis progression after coronary artery bypass graft surgery in patients with type 2 diabetes. Design and rationale of the VeIn-Coronary aTherOsclerosis and Rosiglitazone after bypass surgerY (VICTORY) trial

    PubMed Central

    Bertrand, Olivier F; Poirier, Paul; Rodés-Cabau, Josep; Rinfret, Stéphane; Title, Lawrence; Dzavik, Vladimir; Natarajan, Madhu; Angel, Juan; Batalla, Nuria; Alméras, Natalie; Costerousse, Olivier; De Larochellière, Robert; Roy, Louis; Després, Jean-Pierre

    2009-01-01

    BACKGROUND: The number of patients with coronary artery disease and type 2 diabetes will increase dramatically over the next decade. Diabetes has been related to accelerated atherosclerosis and many patients with diabetes will require coronary artery bypass graft (CABG) surgery utilizing saphenous vein grafts. After CABG, accelerated atherosclerosis in saphenous vein grafts leads to graft failure in approximately 50% of cases over a 10-year period. Rosiglitazone, a peroxisome proliferator-activated receptor-gamma agonist, has been shown to improve multiple metabolic parameters in patients with type 2 diabetes. However, its role in the prevention of atherosclerosis progression is uncertain. STUDY DESIGN: VeIn-Coronary aTherOsclerosis and Rosiglitazone after bypass surgerY (VICTORY) is a cardiometabolic trial in which patients with type 2 diabetes, one to 10 years after CABG, will be randomly assigned to receive rosiglitazone (up to 8 mg/day) or a placebo after qualifying angiography and intravascular ultrasound of a segment of one vein graft with or without a native anastomosed coronary artery. A comprehensive set of athero-thrombo-inflammatory markers will be serially assessed during the 12-month follow-up period. Body fat distribution and body composition will be assessed by computed tomography and dual energy x-ray absorptiometry, respectively, at baseline, six months and 12 months follow-up. For atherosclerosis progression evaluation, repeat angiography and intravascular ultrasound will be performed after 12 months follow-up. The primary end point of the study will be the change in atherosclerotic plaque volume in a 40 mm or longer segment of one vein graft. CONCLUSIONS: The VICTORY trial is the first cardiometabolic study to evaluate the antiatherosclerotic and metabolic effects of rosiglitazone in post-CABG patients with type 2 diabetes. PMID:19746240

  11. The Mapping X-ray Fluorescence Spectrometer (MapX)

    NASA Astrophysics Data System (ADS)

    Sarrazin, P.; Blake, D. F.; Marchis, F.; Bristow, T.; Thompson, K.

    2017-12-01

    Many planetary surface processes leave traces of their actions as features in the size range 10s to 100s of microns. The Mapping X-ray Fluorescence Spectrometer (MapX) will provide elemental imaging at 100 micron spatial resolution, yielding elemental chemistry at a scale where many relict physical, chemical, or biological features can be imaged and interpreted in ancient rocks on planetary bodies and planetesimals. MapX is an arm-based instrument positioned on a rock or regolith with touch sensors. During an analysis, an X-ray source (tube or radioisotope) bombards the sample with X-rays or alpha-particles / gamma-rays, resulting in sample X-ray Fluorescence (XRF). X-rays emitted in the direction of an X-ray sensitive CCD imager pass through a 1:1 focusing lens (X-ray micro-pore Optic (MPO)) that projects a spatially resolved image of the X-rays onto the CCD. The CCD is operated in single photon counting mode so that the energies and positions of individual X-ray photons are recorded. In a single analysis, several thousand frames are both stored and processed in real-time. Higher level data products include single-element maps with a lateral spatial resolution of 100 microns and quantitative XRF spectra from ground- or instrument- selected Regions of Interest (ROI). XRF spectra from ROI are compared with known rock and mineral compositions to extrapolate the data to rock types and putative mineralogies. When applied to airless bodies and implemented with an appropriate radioisotope source for alpha-particle excitation, MapX will be able to analyze biogenic elements C, N, O, P, S, in addition to the cations of the rock-forming elements >Na, accessible with either X-ray or gamma-ray excitation. The MapX concept has been demonstrated with a series of lab-based prototypes and is currently under refinement and TRL maturation.

  12. Cardiac computed tomography in patients with symptomatic new-onset atrial fibrillation, rule-out acute coronary syndrome, but with intermediate pretest probability for coronary artery disease admitted to a chest pain unit.

    PubMed

    Koopmann, Matthias; Hinrichs, Liane; Olligs, Jan; Lichtenberg, Michael; Eckardt, Lars; Böse, Dirk; Möhlenkamp, Stefan; Waltenberger, Johannes; Breuckmann, Frank

    2018-01-24

    Atrial fibrillation (AF) and coronary artery disease (CAD) may be encountered coincidently in a large portion of patients. However, data on coronary artery calcium burden in such patients are lacking. Thus, we sought to determine the value of cardiac computed tomography (CCT) in patients presenting with new-onset AF associated with an intermediate pretest probability for CAD admitted to a chest pain unit (CPU). Calcium scores (CS) of 73 new-onset, symptomatic AF subjects without typical clinical, electrocardiographic, or laboratory signs of acute coronary syndrome (ACS) admitted to our CPU were analyzed. In addition, results from computed tomography angiography (CTA) were related to coronary angiography findings whenever available. Calcium scores of zero were found in 25%. Median Agatston score was 77 (interquartile range: 1-270) with gender- and territory-specific dispersal. CS scores above average were present in about 50%, high (> 400)-to-very high (> 1000) CS scores were found in 22%. Overall percentile ranking showed a relative accordance to the reference percentile distribution. Additional CTA was performed in 47%, revealing stenoses in 12%. Coronary angiography was performed in 22% and resulted in coronary intervention or surgical revascularization in 7%. On univariate analysis, CS > 50th percentile failed to serve as an independent determinant of significant stenosis during catheterization. Within a CPU setting, relevant CAD was excluded or confirmed in almost 50%, the latter with a high proportion of coronary angiographies and subsequent coronary interventions, underlining the diagnostic value of CCT in symptomatic, non-ACS, new-onset AF patients when admitted to a CPU.

  13. Cosmic x ray physics

    NASA Technical Reports Server (NTRS)

    Mccammon, Dan; Cox, D. P.; Kraushaar, W. L.; Sanders, W. T.

    1990-01-01

    The annual progress report on Cosmic X Ray Physics is presented. Topics studied include: the soft x ray background, proportional counter and filter calibrations, the new sounding rocket payload: X Ray Calorimeter, and theoretical studies.

  14. Focusing X-Ray Telescopes

    NASA Technical Reports Server (NTRS)

    O'Dell, Stephen; Brissenden, Roger; Davis, William; Elsner, Ronald; Elvis, Martin; Freeman, Mark; Gaetz, Terrance; Gorenstein, Paul; Gubarev, Mikhall; Jerlus, Diab; hide

    2010-01-01

    During the half-century history of x-ray astronomy, focusing x-ray telescopes, through increased effective area and finer angular resolution, have improved sensitivity by 8 orders of magnitude. Here, we review previous and current x-ray-telescope missions. Next, we describe the planned next-generation x-ray-astronomy facility, the International X-ray Observatory (IXO). We conclude with an overview of a concept for the next next-generation facility, Generation X. Its scientific objectives will require very large areas (about 10,000 sq m) of highly-nested, lightweight grazing-incidence mirrors, with exceptional (about 0.1-arcsec) resolution. Achieving this angular resolution with lightweight mirrors will likely require on-orbit adjustment of alignment and figure.

  15. Totally Endoscopic Coronary Artery Bypass for Anomalous Origin of Right Coronary Artery.

    PubMed

    Kuo, Chia-Cheng; Hsing, Chung-Hsi; Cheng, Bor-Chih

    2017-01-01

    Anomalous origin of the right coronary artery (ARCA) from the left Valsalva sinus is a rare but known cause of sudden cardiac death. Surgical revascularization techniques include coronary artery bypass grafting, unroofing, and reimplantation. We report 4 patients who underwent robot-assisted totally endoscopic coronary artery bypass (TECAB) for ARCA as an alternative surgical option. In 3 patients, a single aortocoronary saphenous vein bypass was performed, and in 1 patient the right internal mammary artery was used. All grafts are patent as shown by computed tomographic angiography or cardiac catheterization. We claim that totally endoscopic coronary artery bypass is feasible and safe for anomalous origin of the right coronary artery. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  16. Lidocaine bolus may facilitate computed tomographic coronary angiography in patients with frequent premature ventricular contractions

    PubMed Central

    Jastrzębski, Jan; Kępka, Cezary; Kruk, Mariusz; Demkow, Marcin; Kalińczuk, Łukasz; Wolny, Rafał; Ciszewski, Michał; Michałowska, Ilona; Witkowski, Adam

    2013-01-01

    Introduction Heart rate irregularities are the major limitations of computed tomographic coronary angiography (CTCA) due to severe motion artifacts. Aim To evaluate the safety and efficacy of a lidocaine intravenous bolus in preserving good image quality by the transient suppression of premature ventricular contractions (PVC) during the CTCA scan. Material and methods The study group comprised 67 consecutive patients with sinus rhythm and numerous PVC scheduled for CTCA. Intravenous boluses of 25–50 mg lidocaine were given after calcium score assessment and immediately before CTCA. The control group comprised 67 patients with sinus rhythm without PVC matched according to the body mass index (BMI), age, sex, and calcium score. All coronary vessel segments were assessed for image quality and presence of significant stenosis. Results As compared with calcium score assessment, after administration of lidocaine and during the CTCA scan PVC were completely suppressed in 22 (40%), reduced in 10 (18%), unchanged in 18 (32%), and intensified in 5 (10%) patients. Overall, there were 32 (58%) patients with sinus rhythm during CTCA as compared with only 11 (20%) patients free from PVC during calcium score assessment (p < 0.001). Image quality in 871 coronary segments including both the study group and control patients was worse in patients with PVC (p < 0.0001). However, there was no statistically significant difference in the number of patients with at least one segment of non-diagnostic quality (6% vs. 12%, p = 0.36; respectively). Conclusions Single lidocaine bolus given prior to CTCA is safe, may temporarily eliminate or reduce the intensity of arrhythmia, and hence results in improved quality of CTCA in patients with numerous PVC. PMID:24570719

  17. Cosmic x ray physics

    NASA Technical Reports Server (NTRS)

    Mccammon, Dan; Cox, D. P.; Kraushaar, W. L.; Sanders, W. T.

    1991-01-01

    The annual progress report on Cosmic X Ray Physics for the period 1 Jan. to 31 Dec. 1990 is presented. Topics studied include: soft x ray background, new sounding rocket payload: x ray calorimeter, and theoretical studies.

  18. X-ray lasers

    NASA Astrophysics Data System (ADS)

    Elton, Raymond C.

    Theoretical and practical aspects of X-ray lasers are discussed in an introduction emphasizing recent advances. Chapters are devoted to the unique optical properties of the X-ray spectral region, the principles of short-wavelength lasers, pumping by exciting plasma ions, pumping by electron capture into excited ionic states, pumping by ionization of atoms and ions, and alternative approaches. The potential scientific, technical, biological, and medical applications of X-ray lasers are briefly characterized.

  19. The superslow pulsation X-ray pulsars in high mass X-ray binaries

    NASA Astrophysics Data System (ADS)

    Wang, Wei

    2013-03-01

    There exists a special class of X-ray pulsars that exhibit very slow pulsation of P spin > 1000 s in the high mass X-ray binaries (HMXBs). We have studied the temporal and spectral properties of these superslow pulsation neutron star binaries in hard X-ray bands with INTEGRAL observations. Long-term monitoring observations find spin period evolution of two sources: spin-down trend for 4U 2206+54 (P spin ~ 5560 s with Ṗ spin ~ 4.9 × 10-7 s s-1) and long-term spin-up trend for 2S 0114+65 (P spin ~ 9600 s with Ṗ spin ~ -1 × 10-6 s s-1) in the last 20 years. A Be X-ray transient, SXP 1062 (P spin ~ 1062 s), also showed a fast spin-down rate of Ṗ spin ~ 3 × 10-6 s s-1 during an outburst. These superslow pulsation neutron stars cannot be produced in the standard X-ray binary evolution model unless the neutron star has a much stronger surface magnetic field (B > 1014 G). The physical origin of the superslow spin period is still unclear. The possible origin and evolution channels of the superslow pulsation X-ray pulsars are discussed. Superslow pulsation X-ray pulsars could be younger X-ray binary systems, still in the fast evolution phase preceding the final equilibrium state. Alternatively, they could be a new class of neutron star system - accreting magnetars.

  20. Miniature x-ray source

    DOEpatents

    Trebes, James E.; Stone, Gary F.; Bell, Perry M.; Robinson, Ronald B.; Chornenky, Victor I.

    2002-01-01

    A miniature x-ray source capable of producing broad spectrum x-ray emission over a wide range of x-ray energies. The miniature x-ray source comprises a compact vacuum tube assembly containing a cathode, an anode, a high voltage feedthru for delivering high voltage to the anode, a getter for maintaining high vacuum, a connection for an initial vacuum pump down and crimp-off, and a high voltage connection for attaching a compact high voltage cable to the high voltage feedthru. At least a portion of the vacuum tube wall is highly x-ray transparent and made, for example, from boron nitride. The compact size and potential for remote operation allows the x-ray source, for example, to be placed adjacent to a material sample undergoing analysis or in proximity to the region to be treated for medical applications.

  1. Wide-area phase-contrast X-ray imaging using large X-ray interferometers

    NASA Astrophysics Data System (ADS)

    Momose, Atsushi; Takeda, Tohoru; Yoneyama, Akio; Koyama, Ichiro; Itai, Yuji

    2001-07-01

    Large X-ray interferometers are developed for phase-contrast X-ray imaging aiming at medical applications. A monolithic X-ray interferometer and a separate one are studied, and currently a 25 mm×20 mm view area can be generated. This paper describes the strategy of our research program and some recent developments.

  2. Limits of the possible: diagnostic image quality in coronary angiography with third-generation dual-source CT.

    PubMed

    Ochs, Marco M; Siepen, Fabian Aus dem; Fritz, Thomas; Andre, Florian; Gitsioudis, Gitsios; Korosoglou, Grigorios; Seitz, Sebastian; Bogomazov, Yuriy; Schlett, Christopher L; Sokiranski, Roman; Sommer, Andre; Gückel, Friedemann; Brado, Matthias; Kauczor, Hans-Ulrich; Görich, Johannes; Friedrich, Matthias G W; Katus, Hugo A; Buss, Sebastian J

    2017-07-01

    The usage of coronary CT angiography (CTA) is appropriate in patients with acute or chronic chest pain; however the diagnostic accuracy may be challenged with increased Agatston score (AS), increased heart rate, arrhythmia and severe obesity. Thus, we aim to determine the potential of the recently introduced third-generation dual-source CT (DSCT) for CTA in a 'real-life' clinical setting. Two hundred and sixty-eight consecutive patients (age: 67 ± 10 years; BMI: 27 ± 5 kg/m²; 61% male) undergoing clinically indicated CTA with DSCT were included in the retrospective single-center analysis. A contrast-enhanced volume dataset was acquired in sequential (SSM) (n = 151) or helical scan mode (HSM) (n = 117). Coronary segments were classified in diagnostic or non-diagnostic image quality. A subset underwent invasive angiography to determine the diagnostic accuracy of CTA. SSM (96.8 ± 6%) and HSM (97.5 ± 8%) provided no significant differences in the overall diagnostic image quality. However, AS had significant influence on diagnostic image quality exclusively in SSM (B = 0.003; p = 0.0001), but not in HSM. Diagnostic image quality significantly decreased in SSM in patients with AS ≥2,000 (p = 0.03). SSM (sensitivity: 93.9%; specificity: 96.7%; PPV: 88.6%; NPV: 98.3%) and HSM (sensitivity: 97.4%; specificity: 94.3%; PPV: 86.0%; NPV: 99.0%) provided comparable diagnostic accuracy (p = n.s.). SSM yielded significantly lower radiation doses as compared to HSM (2.1 ± 2.0 vs. 5.1 ± 3.3 mSv; p = 0.0001) in age and BMI-matched cohorts. SSM in third-generation DSCT enables significant dose savings and provides robust diagnostic image quality in patients with AS ≤2000 independent of heart rate, heart rhythm or obesity.

  3. X-Pinch And Its Applications In X-ray Radiograph

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zou Xiaobing; Wang Xinxin; Liu Rui

    2009-07-07

    An X-pinch device and the related diagnostics of x-ray emission from X-pinch were briefly described. The time-resolved x-ray measurements with photoconducting diodes show that the x-ray pulse usually consists of two subnanosecond peaks with a time interval of about 0.5 ns. Being consistent with these two peaks of the x-ray pulse, two point x-ray sources of size ranging from 100 mum to 5 mum and depending on cut-off x-ray photon energy were usually observed on the pinhole pictures. The x-pinch was used as x-ray source for backlighting of the electrical explosion of single wire and the evolution of X-pinch, andmore » for phase-contrast imaging of soft biological objects such as a small shrimp and a mosquito.« less

  4. Evolution of X-ray astronomy

    NASA Technical Reports Server (NTRS)

    Rossj, B.

    1981-01-01

    The evolution of X-ray astronomy up to the launching of the Einstein observatory is presented. The evaluation proceeded through the following major steps: (1) discovery of an extrasolar X-ray source, Sco X-1, orders of magnitude stronger than astronomers believed might exist; (2) identification of a strong X-ray source with the Crab Nebula; (3) identification of Sco X-1 with a faint, peculiar optical object; (4) demonstration that X-ray stars are binary systems, each consisting of a collapsed object accreting matter from an ordinary star; (5) discovery of X-ray bursts; (6) discovery of exceedingly strong X-ray emission from active galaxies, quasars and clusters of galaxies; (7) demonstration that the principal X-ray source is a hot gas filling the space between galaxies.

  5. Active x-ray optics for Generation-X, the next high resolution x-ray observatory

    NASA Astrophysics Data System (ADS)

    Elvis, Martin; Brissenden, R. J.; Fabbiano, G.; Schwartz, D. A.; Reid, P.; Podgorski, W.; Eisenhower, M.; Juda, M.; Phillips, J.; Cohen, L.; Wolk, S.

    2006-06-01

    X-rays provide one of the few bands through which we can study the epoch of reionization, when the first galaxies, black holes and stars were born. To reach the sensitivity required to image these first discrete objects in the universe needs a major advance in X-ray optics. Generation-X (Gen-X) is currently the only X-ray astronomy mission concept that addresses this goal. Gen-X aims to improve substantially on the Chandra angular resolution and to do so with substantially larger effective area. These two goals can only be met if a mirror technology can be developed that yields high angular resolution at much lower mass/unit area than the Chandra optics, matching that of Constellation-X (Con-X). We describe an approach to this goal based on active X-ray optics that correct the mid-frequency departures from an ideal Wolter optic on-orbit. We concentrate on the problems of sensing figure errors, calculating the corrections required, and applying those corrections. The time needed to make this in-flight calibration is reasonable. A laboratory version of these optics has already been developed by others and is successfully operating at synchrotron light sources. With only a moderate investment in these optics the goals of Gen-X resolution can be realized.

  6. Multislice Computed Tomography Accurately Detects Stenosis in Coronary Artery Bypass Conduits

    PubMed Central

    Duran, Cihan; Sagbas, Ertan; Caynak, Baris; Sanisoglu, Ilhan; Akpinar, Belhhan; Gulbaran, Murat

    2007-01-01

    The aim of this study was to evaluate the accuracy of multislice computed tomography in detecting graft stenosis or occlusion after coronary artery bypass grafting, using coronary angiography as the standard. From January 2005 through May 2006, 25 patients (19 men and 6 women; mean age, 54 ± 11.3 years) underwent diagnostic investigation of their bypass grafts by multislice computed tomography within 1 month of coronary angiography. The mean time elapsed after coronary artery bypass grafting was 6.2 years. In these 25 patients, we examined 65 bypass conduits (24 arterial and 41 venous) and 171 graft segments (the shaft, proximal anastomosis, and distal anastomosis). Compared with coronary angiography, the segment-based sensitivity, specificity, and positive and negative predictive values of multislice computed tomography in the evaluation of stenosis were 89%, 100%, 100%, and 99%, respectively. The patency rate for multislice compu-ted tomography was 85% (55/65: 3 arterial and 7 venous grafts were occluded), with 100% sensitivity and specificity. From these data, we conclude that multislice computed tomography can accurately evaluate the patency and stenosis of bypass grafts during outpatient follow-up. PMID:17948078

  7. Development of X-ray CCD camera based X-ray micro-CT system

    NASA Astrophysics Data System (ADS)

    Sarkar, Partha S.; Ray, N. K.; Pal, Manoj K.; Baribaddala, Ravi; Agrawal, Ashish; Kashyap, Y.; Sinha, A.; Gadkari, S. C.

    2017-02-01

    Availability of microfocus X-ray sources and high resolution X-ray area detectors has made it possible for high resolution microtomography studies to be performed outside the purview of synchrotron. In this paper, we present the work towards the use of an external shutter on a high resolution microtomography system using X-ray CCD camera as a detector. During micro computed tomography experiments, the X-ray source is continuously ON and owing to the readout mechanism of the CCD detector electronics, the detector registers photons reaching it during the read-out period too. This introduces a shadow like pattern in the image known as smear whose direction is defined by the vertical shift register. To resolve this issue, the developed system has been incorporated with a synchronized shutter just in front of the X-ray source. This is positioned in the X-ray beam path during the image readout period and out of the beam path during the image acquisition period. This technique has resulted in improved data quality and hence the same is reflected in the reconstructed images.

  8. Rationale and design of a randomised clinical trial comparing vascular closure device and manual compression to achieve haemostasis after diagnostic coronary angiography: the Instrumental Sealing of ARterial puncture site - CLOSURE device versus manual compression (ISAR-CLOSURE) trial.

    PubMed

    Xhepa, Erion; Byrne, Robert A; Schulz, Stefanie; Helde, Sandra; Gewalt, Senta; Cassese, Salvatore; Linhardt, Maryam; Ibrahim, Tareq; Mehilli, Julinda; Hoppe, Katharina; Grupp, Katharina; Kufner, Sebastian; Böttiger, Corinna; Hoppmann, Petra; Burgdorf, Christof; Fusaro, Massimiliano; Ott, Ilka; Schneider, Simon; Hengstenberg, Christian; Schunkert, Heribert; Laugwitz, Karl-Ludwig; Kastrati, Adnan

    2014-06-01

    Vascular closure devices (VCD) have been introduced into clinical practice with the aim of increasing the procedural efficiency and clinical safety of coronary angiography. However, clinical studies comparing VCD and manual compression have yielded mixed results, and large randomised clinical trials comparing the two strategies are missing. Moreover, comparative efficacy studies between different VCD in routine clinical use are lacking. The Instrumental Sealing of ARterial puncture site - CLOSURE device versus manual compression (ISAR-CLOSURE) trial is a prospective, randomised clinical trial designed to compare the outcomes associated with the use of VCD or manual compression to achieve femoral haemostasis. The test hypothesis is that femoral haemostasis after coronary angiography achieved using VCD is not inferior to manual compression in terms of access-site-related vascular complications. Patients undergoing coronary angiography via the common femoral artery will be randomised in a 1:1:1 fashion to receive FemoSeal VCD, EXOSEAL VCD or manual compression. The primary endpoint is the incidence of the composite of arterial access-related complications (haematoma ≥5 cm, pseudoaneurysm, arteriovenous fistula, access-site-related bleeding, acute ipsilateral leg ischaemia, the need for vascular surgical/interventional treatment or documented local infection) at 30 days after randomisation. According to power calculations based on non-inferiority hypothesis testing, enrolment of 4,500 patients is planned. The trial is registered at www.clinicaltrials.gov (study identifier: NCT01389375). The safety of VCD as compared to manual compression in patients undergoing transfemoral coronary angiography remains an issue of clinical equipoise. The aim of the ISAR-CLOSURE trial is to assess whether femoral haemostasis achieved through the use of VCD is non-inferior to manual compression in terms of access-site-related vascular complications.

  9. Selective Angiography Using the Radiofrequency Catheter: An Alternative Technique for Mapping and Ablation in the Aortic Cusps.

    PubMed

    Roca-Luque, Ivo; Rivas, Nuria; Francisco, Jaume; Perez, Jordi; Acosta, Gabriel; Oristrell, Gerard; Terricabres, Maria; Garcia-Dorado, David; Moya, Angel

    2017-01-01

    Ablation in aortic cusps could be necessary in up to 15% of the patients, especially in para-Hisian atrial tachycardia and ventricular arrhythmias arising from outflow tracts. Risk of coronary damage has led to recommendation of systematic coronary angiography (CA) during the procedure. Other image tests as intravascular (ICE) or transesophageal echocardiography (TEE) have been proposed. Both methods have limitations: additional vascular access for ICE and need for additional CA in some patients in case of TEE. We describe an alternative method to assess relation of catheter tip and coronary ostia during ablation in aortic cusps without additional vascular accesses by performing selective angiography with the ablation catheter. We prospectively evaluated 12 consecutive patients (69.3 ± 8.5, 6 female) who underwent ablation in right (1), left (5), and noncoronary cusps (6). We performed angiography through the ablation cooled tip radiofrequency catheter at the ablation site. Ablation was effective in 91.6% of the patients (3 patients needed additional ablation out of coronary cusps: pulmonary cusp, right ventricular outflow tract (RVOT), and coronary sinus and 1 patient underwent a second procedure because recurrence). No complications occurred neither during procedure nor follow-up (6.2 ± 3.8 months). No technical problems occurred with the ablation catheter after contrast injection. Selective angiography through a cooled-tip radiofrequency ablation catheter is feasible to assess relation of coronary ostia and ablation site when ablation in aortic cusps. It allows continuous real-time assessment of this relation, avoids the need for additional vascular accesses and no complications occurred in our series. © 2016 Wiley Periodicals, Inc.

  10. Chandra X-ray Observatory - NASA's flagship X-ray telescope

    Science.gov Websites

    astronomy, taking its place in the fleet of "Great Observatories." Who we are NASA's Chandra X-ray astronomy, distances are measured in units of light years, where one light year is the distance that light gravity? The answer is still out there. By studying clusters of galaxies, X-ray astronomy is tackling this

  11. Diffraction leveraged modulation of X-ray pulses using MEMS-based X-ray optics

    DOEpatents

    Lopez, Daniel; Shenoy, Gopal; Wang, Jin; Walko, Donald A.; Jung, Il-Woong; Mukhopadhyay, Deepkishore

    2016-08-09

    A method and apparatus are provided for implementing Bragg-diffraction leveraged modulation of X-ray pulses using MicroElectroMechanical systems (MEMS) based diffractive optics. An oscillating crystalline MEMS device generates a controllable time-window for diffraction of the incident X-ray radiation. The Bragg-diffraction leveraged modulation of X-ray pulses includes isolating a particular pulse, spatially separating individual pulses, and spreading a single pulse from an X-ray pulse-train.

  12. Comparative effectiveness of coronary CT angiography vs stress cardiac imaging in patients following hospital admission for chest pain work-up: The Prospective First Evaluation in Chest Pain (PERFECT) Trial.

    PubMed

    Uretsky, Seth; Argulian, Edgar; Supariwala, Azhar; Agarwal, Shiv K; El-Hayek, Georges; Chavez, Patricia; Awan, Hira; Jagarlamudi, Ashadevi; Puppala, Siva P; Cohen, Randy; Rozanski, Alan

    2017-08-01

    Because the frequency of cardiac event rates is low among chest pain patients following either performance of coronary CT angiography (CCTA) or stress testing, there is a need to better assess how these tests influence the central management decisions that follow from cardiac testing. The present study was performed to assess the relative impact of CCTA vs stress testing on medical therapies and downstream resource utilization among patients admitted for the work-up of chest pain. The admitted patients were randomized in a 1:1 ratio to either cardiac imaging stress test or CCTA. Primary outcomes were time to discharge, change in medication usage, and frequency of downstream testing, cardiac interventions, and cardiovascular re-hospitalizations. We randomized 411 patients, 205 to stress testing, and 206 to CCTA. There were no differences in time to discharge or initiation of new cardiac medications at discharge. At 1 year follow-up, there was no difference in the number of patients who underwent cardiovascular downstream tests in the CCTA vs stress test patients (21% vs 15%, P = .1) or cardiovascular hospitalizations (14% vs 16%, P = .5). However, there was a higher frequency of invasive angiography in the CCTA group (11% vs 2%, P = .001) and percutaneous coronary interventions (6% vs 0%, P < .001). Randomization of hospitalized patients admitted for chest pain work-up to either CCTA or to stress testing resulted in similar discharge times, change in medical therapies at discharge, frequency of downstream noninvasive testing, and repeat hospitalizations. However, a higher frequency of invasive coronary angiography and revascularization procedures were performed in the CCTA arm. (ClinicalTrials.gov number, NCT01604655.).

  13. 13.1 micrometers hard X-ray focusing by a new type monocapillary X-ray optic designed for common laboratory X-ray source

    NASA Astrophysics Data System (ADS)

    Sun, Xuepeng; zhang, Xiaoyun; Zhu, Yu; Wang, Yabing; Shang, Hongzhong; Zhang, Fengshou; Liu, Zhiguo; Sun, Tianxi

    2018-04-01

    A new type of monocapillary X-ray optic, called 'two bounces monocapillary X-ray optics' (TBMXO), is proposed for generating a small focal spot with high power-density gain for micro X-ray analysis, using a common laboratory X-ray source. TBMXO is consists of two parts: an ellipsoidal part and a tapered part. Before experimental testing, the TBMXO was simulated by the ray tracing method in MATLAB. The simulated results predicted that the proposed TBMXO would produce a smaller focal spot with higher power-density gain than the ellipsoidal monocapillary X-ray optic (EMXO). In the experiment, the TBMXO performance was tested by both an optical device and a Cu target X-ray tube with focal spot of 100 μm. The results indicated that the TBMXO had a slope error of 57.6 μrad and a 13.1 μm focal spot and a 1360 gain in power density were obtained.

  14. X-Ray Exam: Hip

    MedlinePlus

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Hip KidsHealth / For Parents / X-Ray Exam: Hip What's in this article? What ... Have Questions Print What It Is A hip X-ray is a safe and painless test that ...

  15. X-Ray Exam: Forearm

    MedlinePlus

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Forearm KidsHealth / For Parents / X-Ray Exam: Forearm What's in this article? What ... Have Questions Print What It Is A forearm X-ray is a safe and painless test that ...

  16. X-Ray Exam: Ankle

    MedlinePlus

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Ankle KidsHealth / For Parents / X-Ray Exam: Ankle What's in this article? What ... Have Questions Print What It Is An ankle X-ray is a safe and painless test that ...

  17. X-Ray Exam: Foot

    MedlinePlus

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Foot KidsHealth / For Parents / X-Ray Exam: Foot What's in this article? What ... Have Questions Print What It Is A foot X-ray is a safe and painless test that ...

  18. X-Ray Exam: Wrist

    MedlinePlus

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Wrist KidsHealth / For Parents / X-Ray Exam: Wrist What's in this article? What ... Have Questions Print What It Is A wrist X-ray is a safe and painless test that ...

  19. X-Ray Exam: Finger

    MedlinePlus

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Finger KidsHealth / For Parents / X-Ray Exam: Finger What's in this article? What ... Have Questions Print What It Is A finger X-ray is a safe and painless test that ...

  20. X-Ray Exam: Pelvis

    MedlinePlus

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Pelvis KidsHealth / For Parents / X-Ray Exam: Pelvis What's in this article? What ... Have Questions Print What It Is A pelvis X-ray is a safe and painless test that ...

  1. X-ray based extensometry

    NASA Technical Reports Server (NTRS)

    Jordan, E. H.; Pease, D. M.

    1988-01-01

    A totally new method of extensometry using an X-ray beam was proposed. The intent of the method is to provide a non-contacting technique that is immune to problems associated with density variations in gaseous environments that plague optical methods. X-rays are virtually unrefractable even by solids. The new method utilizes X-ray induced X-ray fluorescence or X-ray induced optical fluorescence of targets that have melting temperatures of over 3000 F. Many different variations of the basic approaches are possible. In the year completed, preliminary experiments were completed which strongly suggest that the method is feasible. The X-ray induced optical fluorescence method appears to be limited to temperatures below roughly 1600 F because of the overwhelming thermal optical radiation. The X-ray induced X-ray fluorescence scheme appears feasible up to very high temperatures. In this system there will be an unknown tradeoff between frequency response, cost, and accuracy. The exact tradeoff can only be estimated. It appears that for thermomechanical tests with cycle times on the order of minutes a very reasonable system may be feasible. The intended applications involve very high temperatures in both materials testing and monitoring component testing. Gas turbine engines, rocket engines, and hypersonic vehicles (NASP) all involve measurement needs that could partially be met by the proposed technology.

  2. [Right ventricular dilatation in patients with coronary heart disease without myocardial infarction: According to the data of the Coronary Angiography Surgery Registry].

    PubMed

    Kuznetsov, V A; Yaroslavskaya, E I; Pushkarev, G S; Krinochkin, D V; Bessonov, I S; Gorbatenko, E A

    2015-01-01

    To identify factors associated with right ventricular (RV) dilatation in patients with coronary heart disease (CHD) without prior myocardial infarction (Ml). Out of 16 839 patents from the Coronary Angiography Surgery Registry, the investigators selected patients with >75% stenosis in at least one coronary artery without acute or prior MI: 75 patients with echocardiographically detected RV dilatation and 1134 without RV dilatation. Among the patients with RV dilatation, there were more men (92% versus 80.2%; p=0.01 2). In this group, the mean body mass index (BMI) was higher (31.7±5.2 kg/m2 versus 30.1±4.7 kg/m2; p=0.01 9); there was more commonly higher NYHA functional class (FC) (III) chronic heart failure (CHF) (22.2% versus 12.5%; p=0.002), clinically relevant mitral regurgitation (29.4% versus 4.0%; all ps<0.001), and cardiac rhythm and conduction disturbances (45.5% versus 17.8%; p<0.001) in rarer severe FC (III-IV) exertional angina (30.3% versus 52.8%; p=0.007). The groups were different as evidenced by coronarography and major blood biochemical indicators. Decreased myocardial contractility (odds ratio (OR), 4.22; p=0.002), male sex (OR, 4.03;p=0.007), cardiac rhythm and conduction disturbances (OR, 2.98; p<0.001), clinically relevant mitral regurgitation (OR, 2.34; p=0.001); higher FC CHF (OR, 1.87; p=0.034), BMI (OR, 1.08; p=0.01 0), and lower FC exertional angina (OR, 0.42; p=0.001) demonstrated an independent relationship to RV dilatation, as evidenced by a multivariateanalysis. In the patients with CHD without MI, RV dilatation is independently related to male sex, left ventricular functional characteristics, and higher BMI.

  3. Multislice spiral computed tomography for the evaluation of stent patency after left main coronary artery stenting: a comparison with conventional coronary angiography and intravascular ultrasound.

    PubMed

    Van Mieghem, Carlos A G; Cademartiri, Filippo; Mollet, Nico R; Malagutti, Patrizia; Valgimigli, Marco; Meijboom, Willem B; Pugliese, Francesca; McFadden, Eugene P; Ligthart, Jurgen; Runza, Giuseppe; Bruining, Nico; Smits, Pieter C; Regar, Evelyn; van der Giessen, Willem J; Sianos, Georgios; van Domburg, Ron; de Jaegere, Peter; Krestin, Gabriel P; Serruys, Patrick W; de Feyter, Pim J

    2006-08-15

    Surveillance conventional coronary angiography (CCA) is recommended 2 to 6 months after stent-supported left main coronary artery (LMCA) percutaneous coronary intervention due to the unpredictable occurrence of in-stent restenosis (ISR), with its attendant risks. Multislice computed tomography (MSCT) is a promising technique for noninvasive coronary evaluation. We evaluated the diagnostic performance of high-resolution MSCT to detect ISR after stenting of the LMCA. Seventy-four patients were prospectively identified from a consecutive patient population scheduled for follow-up CCA after LMCA stenting and underwent MSCT before CCA. Until August 2004, a 16-slice scanner was used (n = 27), but we switched to the 64-slice scanner after that period (n = 43). Patients with initial heart rates > 65 bpm received beta-blockers, which resulted in a mean periscan heart rate of 57 +/- 7 bpm. Among patients with technically adequate scans (n = 70), MSCT correctly identified all patients with ISR (10 of 70) but misclassified 5 patients without ISR (false-positives). Overall, the accuracy of MSCT for detection of angiographic ISR was 93%. The sensitivity, specificity, and positive and negative predictive values were 100%, 91%, 67%, and 100%, respectively. When analysis was restricted to patients with stenting of the LMCA with or without extension into a single major side branch, accuracy was 98%. When both branches of the LMCA bifurcation were stented, accuracy was 83%. For the assessment of stent diameter and area, MSCT showed good correlation with intravascular ultrasound (r = 0.78 and 0.73, respectively). An intravascular ultrasound threshold value > or = 1 mm was identified to reliably detect in-stent neointima hyperplasia with MSCT. Current MSCT technology, in combination with optimal heart rate control, allows reliable noninvasive evaluation of selected patients after LMCA stenting. MSCT is safe to exclude left main ISR and may therefore be an acceptable first

  4. Technetium-99m tetrofosmin rest/stress myocardial SPET with a same-day 2-hour protocol: comparison with coronary angiography. A Spanish-Portuguese multicentre clinical trial.

    PubMed

    Montz, R; Perez-Castejón, M J; Jurado, J A; Martín-Comín, J; Esplugues, E; Salgado, L; Ventosa, A; Cantinho, G; Sá, E P; Fonseca, A T; Vieira, M R

    1996-06-01

    Technetium-99m tetrofosmin (Myoview) has unique properties for myocardial perfusion imaging very early after injection of the tracer. We used a very short same-day rest/stress protocol, to be performed within 2 h and evaluated its diagnostic accuracy. The study included 144 patients from seven Spanish and four Portuguese centres with a diagnosis of uncomplicated coronary artery disease (CAD); 78 patients (54%) had no history of prior myocardial infarction. Patients were injected with coronary angiography (CA). The data of 142 patients were completely evaluable (two with non-evaluable images were excluded). The quality of rest images was excellent or good in 86%, regionally problematic in 7%, poor but well interpretable in 5% and non-evaluable in 2%. The overall sensitivity for the detection of CAD was 93%, the specificity 38% and the accuracy 85%. The localization of defects by SPET in relation to the perfusion territories of stenosed vessels (>/=50%) was achieved with a sensitivity of 64% for the left anterior descending artery, 49% for the left circumflex artery and 86% for the right coronary artery, and an accuracy of 71%, 72% and 73% respectively. Concordance of SPET and CA was 62% for single-vessel disease and 68% for multivessel disease. In conclusion, this Spanish-Portuguese multicentre clinical trial confirmed, in a considerable number of patients who underwent coronary angiography, the feasibility of 99mTc tetrofosmin (Myoview) rest/stress myocardial SPET using a very short protocol (2 h).

  5. Applications of phase-contrast x-ray imaging to medicine using an x-ray interferometer

    NASA Astrophysics Data System (ADS)

    Momose, Atsushi; Yoneyama, Akio; Takeda, Tohoru; Itai, Yuji; Tu, Jinhong; Hirano, Keiichi

    1999-10-01

    We are investigating possible medical applications of phase- contrast X-ray imaging using an X-ray interferometer. This paper introduces the strategy of the research project and the present status. The main subject is to broaden the observation area to enable in vivo observation. For this purpose, large X-ray interferometers were developed, and 2.5 cm X 1.5 cm interference patterns were generated using synchrotron X-rays. An improvement of the spatial resolution is also included in the project, and an X-ray interferometer designed for high-resolution phase-contrast X-ray imaging was fabricated and tested. In parallel with the instrumental developments, various soft tissues are observed by phase- contrast X-ray CT to find correspondence between the generated contrast and our histological knowledge. The observation done so far suggests that cancerous tissues are differentiated from normal tissues and that blood can produce phase contrast. Furthermore, this project includes exploring materials that modulate phase contrast for selective imaging.

  6. Association between serum N-terminal pro-B-type natriuretic peptide levels and characteristics of coronary atherosclerotic plaque detected by coronary computed tomography angiography.

    PubMed

    Gan, Lu; Feng, Cong; Liu, Chunlei; Tian, Shuping; Song, Xiang; Yang, Li

    2016-08-01

    The aim of the present study was to explore the association between the levels of serum N-terminal pro-B-type natriuretic peptide (NT-pro BNP) and the characteristics of coronary atherosclerotic plaque detected by coronary computed tomography angiography (CCTA), in patients with unstable angina (UA). A total of 202 patients (age range, 47-82 years) were divided into the following three groups: Non-cardiac disease group (57 patients); stable angina pectoris (SAP) group (62 patients); and UA group (83 patients). There were significant differences between the serum NT-pro BNP levels among the three groups (P=0.007). However, in multivariant diagnoses, NT-pro BNP level was not an independent risk factor for UA. The levels of serum NT-pro BNP were observed to be positively correlated with the number of vessels involved (r=0.462; P<0.001), SIS (r=0.475; P<0.001), segment-stenosis score (r=0.453; P<0.001), coronary calcification score (r=0.412; P=0.001), number of obstructive diseases (r=0.346; P<0.001), and the number of segments with non-calcified plaque (r=0.235; P=0.017), mixed plaque (r=0.234; P=0.017) and calcified plaque (r=0.431; P<0.001). The levels of serum NT-pro BNP were significantly higher in patients with UA and left main-left anterior descending (LM-LAD) disease, compared with UA patients without LM-LAD disease (P<0.001). In addition, serum NT-pro BNP was significantly higher in patients with obstructive disease and UA than in those without obstructive disease (P<0.001). The area under the curve of log(NT-pro BNP) was 0.656 (P=0.006; optimal cut-off value, 1.74; sensitivity, 77.6%; specificity, 51.9%). In conclusion, the levels of serum NT-pro BNP are associated with the burden and severity of coronary artery atherosclerotic disease in patients with UA, and may be helpful in risk stratification of patients with UA.

  7. Association between serum N-terminal pro-B-type natriuretic peptide levels and characteristics of coronary atherosclerotic plaque detected by coronary computed tomography angiography

    PubMed Central

    Gan, Lu; Feng, Cong; Liu, Chunlei; Tian, Shuping; Song, Xiang; Yang, Li

    2016-01-01

    The aim of the present study was to explore the association between the levels of serum N-terminal pro-B-type natriuretic peptide (NT-pro BNP) and the characteristics of coronary atherosclerotic plaque detected by coronary computed tomography angiography (CCTA), in patients with unstable angina (UA). A total of 202 patients (age range, 47–82 years) were divided into the following three groups: Non-cardiac disease group (57 patients); stable angina pectoris (SAP) group (62 patients); and UA group (83 patients). There were significant differences between the serum NT-pro BNP levels among the three groups (P=0.007). However, in multivariant diagnoses, NT-pro BNP level was not an independent risk factor for UA. The levels of serum NT-pro BNP were observed to be positively correlated with the number of vessels involved (r=0.462; P<0.001), SIS (r=0.475; P<0.001), segment-stenosis score (r=0.453; P<0.001), coronary calcification score (r=0.412; P=0.001), number of obstructive diseases (r=0.346; P<0.001), and the number of segments with non-calcified plaque (r=0.235; P=0.017), mixed plaque (r=0.234; P=0.017) and calcified plaque (r=0.431; P<0.001). The levels of serum NT-pro BNP were significantly higher in patients with UA and left main-left anterior descending (LM-LAD) disease, compared with UA patients without LM-LAD disease (P<0.001). In addition, serum NT-pro BNP was significantly higher in patients with obstructive disease and UA than in those without obstructive disease (P<0.001). The area under the curve of log(NT-pro BNP) was 0.656 (P=0.006; optimal cut-off value, 1.74; sensitivity, 77.6%; specificity, 51.9%). In conclusion, the levels of serum NT-pro BNP are associated with the burden and severity of coronary artery atherosclerotic disease in patients with UA, and may be helpful in risk stratification of patients with UA. PMID:27446259

  8. Frontiers of X-Ray Astronomy

    NASA Astrophysics Data System (ADS)

    Fabian, Andrew C.; Pounds, Kenneth A.; Blandford, Roger D.

    2004-07-01

    Preface; 1. Forty years on from Aerobee 150: a personal perspective K. Pounds; 2. X-ray spectroscopy of astrophysical plasmas S. M. Kahn, E. Behar, A. Kinkhabwala and D. W. Savin; 3. X-rays from stars M. Gudel; 4. X-ray observations of accreting white-dwarf systems M. Cropper, G. Ramsay, C. Hellier, K. Mukai, C. Mauche and D. Pandel; 5. Accretion flows in X-ray binaries C. Done; 6. Recent X-ray observations of supernova remnants C. R. Canizares; 7. Luminous X-ray sources in spiral and star-forming galaxies M. Ward; 8. Cosmological constraints from Chandra observations of galaxy clusters S. W. Allen; 9. Clusters of galaxies: a cosmological probe R. Mushotzky; 10. Obscured active galactic nuclei: the hidden side of the X-ray Universe G. Matt; 11. The Chandra Deep Field-North Survey and the cosmic X-ray background W. N. Brandt, D. M. Alexander, F. E. Bauer and A. E. Hornschemeier; 12. Hunting the first black holes G. Hasinger; 13. X-ray astronomy in the new millennium: a summary R. D. Blandford.

  9. X-ray laser microscope apparatus

    DOEpatents

    Suckewer, Szymon; DiCicco, Darrell S.; Hirschberg, Joseph G.; Meixler, Lewis D.; Sathre, Robert; Skinner, Charles H.

    1990-01-01

    A microscope consisting of an x-ray contact microscope and an optical microscope. The optical, phase contrast, microscope is used to align a target with respect to a source of soft x-rays. The source of soft x-rays preferably comprises an x-ray laser but could comprise a synchrotron or other pulse source of x-rays. Transparent resist material is used to support the target. The optical microscope is located on the opposite side of the transparent resist material from the target and is employed to align the target with respect to the anticipated soft x-ray laser beam. After alignment with the use of the optical microscope, the target is exposed to the soft x-ray laser beam. The x-ray sensitive transparent resist material whose chemical bonds are altered by the x-ray beam passing through the target mater GOVERNMENT LICENSE RIGHTS This invention was made with government support under Contract No. De-FG02-86ER13609 awarded by the Department of Energy. The Government has certain rights in this invention.

  10. Compound refractive X-ray lens

    DOEpatents

    Nygren, David R.; Cahn, Robert; Cederstrom, Bjorn; Danielsson, Mats; Vestlund, Jonas

    2000-01-01

    An apparatus and method for focusing X-rays. In one embodiment, his invention is a commercial-grade compound refractive X-ray lens. The commercial-grade compound refractive X-ray lens includes a volume of low-Z material. The volume of low-Z material has a first surface which is adapted to receive X-rays of commercially-applicable power emitted from a commercial-grade X-ray source. The volume of low-Z material also has a second surface from which emerge the X-rays of commercially-applicable power which were received at the first surface. Additionally, the commercial-grade compound refractive X-ray lens includes a plurality of openings which are disposed between the first surface and the second surface. The plurality of openings are oriented such that the X-rays of commercially-applicable power which are received at the first surface, pass through the volume of low-Z material and through the plurality openings. In so doing, the X-rays which emerge from the second surface are refracted to a focal point.

  11. Management of coronary artery disease

    NASA Astrophysics Data System (ADS)

    Safri, Z.

    2018-03-01

    Coronary Artery Disease (CAD) is associated with significant morbidity and mortality, therefore it’s important to early and accurate detection and appropriate management. Diagnosis of CAD include clinical examination, noninvasive techniques such as biochemical testing, a resting ECG, possibly ambulatory ECG monitoring, resting echocardiography, chest X-ray in selected patients; and catheterization. Managements of CAD patients include lifestyle modification, control of CAD risk factors, pharmacologic therapy, and patient education. Revascularization consists of percutaneous coronary angioplasty and coronary artery bypass grafting. Cardiac rehabilitation should be considered in all patients with CAD. This comprehensive review highlights strategies of management in patients with CAD.

  12. Cosmic X-ray physics

    NASA Technical Reports Server (NTRS)

    Mccammon, D.; Cox, D. P.; Kraushaar, W. L.; Sanders, W. T.

    1985-01-01

    A progress report of research activities carried out in the area of cosmic X-ray physics is presented. The Diffuse X-ray Spectrometer DXS which has been flown twice as a rocket payload is described. The observation times proved to be too small for meaningful X-ray data to be obtained. Data collection and reduction activities from the Ultra-Soft X-ray background (UXT) instrument are described. UXT consists of three mechanically-collimated X-ray gas proportional counters with window/filter combinations which allow measurements in three energy bands, Be (80-110 eV), B (90-187 eV), and O (e84-532 eV). The Be band measurements provide an important constraint on local absorption of X-rays from the hot component of the local interstellar medium. Work has also continued on the development of a calorimetric detector for high-resolution spectroscopy in the 0.1 keV - 8keV energy range.

  13. Manual Versus Mechanical Compression of the Radial Artery After Transradial Coronary Angiography: The MEMORY Multicenter Randomized Trial.

    PubMed

    Petroglou, Dimitrios; Didagelos, Matthaios; Chalikias, Georgios; Tziakas, Dimitrios; Tsigkas, Grigorios; Hahalis, Georgios; Koutouzis, Michael; Ntatsios, Antonios; Tsiafoutis, Ioannis; Hamilos, Michael; Kouparanis, Antonios; Konstantinidis, Nikolaos; Sofidis, Georgios; Pancholy, Samir B; Karvounis, Haralambos; Bertrand, Olivier Francois; Ziakas, Antonios

    2018-06-11

    The aim of this study was to compare manual versus mechanical compression of the radial artery after coronary angiography via transradial access regarding radial artery occlusion (RAO), access-site bleeding complications, and duration of hemostasis. Hemostasis of the radial artery after sheath removal can be achieved either by manual compression at the puncture site or by using a mechanical hemostasis device. Because mechanical compression exerts a more stable, continuous pressure on the artery, it could be hypothesized that it is more effective compared with manual compression regarding hemostasis time, bleeding, and RAO risks. A total of 589 patients undergoing diagnostic coronary angiography by transradial access with a 5-F sheath were randomized in a 1:1 ratio to receive either manual or mechanical patent hemostasis of the radial artery. Radial artery patency was evaluated by color duplex ultrasonography 24 h after the procedure. The primary endpoint was early RAO at 24 h. Secondary endpoints included access-site bleeding complications and duration of hemostasis. Thirty-six (12%) early RAOs occurred in the manual group, and 24 (8%) occurred in the mechanical group (p = 0.176). There were no significant differences between the 2 groups regarding access-site bleeding complications (hematoma, 52 [17%] vs. 50 [18%]; p = 0.749; bleedings, 8 [3%] vs. 9 [3%]; p = 1.000). Duration of hemostasis was significantly shorter in the manual group (22 ± 34 min vs. 119 ± 72 min with mechanical compression; p < 0.001). Manual and mechanical compression resulted in similar rates of early RAO, although the total duration of hemostasis was significantly shorter in the manual group. Copyright © 2018 American College of Cardiology Foundation. All rights reserved.

  14. Successful transradial intervention for two lesions with dual anomalous origins of coronary arteries.

    PubMed

    Masuda, Naoki; Matsukage, Takashi; Ikari, Yuji

    2011-05-01

    A 76-year-old male was admitted to our hospital for effort angina pectoris. His coronary computed tomography and coronary angiography revealed anomalous origins of the left anterior descending artery (LAD) from the proximal right coronary artery (RCA) and the left circumflex coronary artery (LCX) from the separate ostium in the right coronary cusp. Severe stenoses were present in the proximal segment of the LAD and in the middle segment of the LCX, which were successfully treated by 5 French (Fr) transradial approach intervention. Congenital coronary anomalies are relatively rare, with a prevalence of approximately 1.3% in a large-series study undergoing coronary angiography. Such anomalies occur in several anatomical arrangements, which have been classified in a number of research reports. Here we describe previously unreported dual anomalous origins of coronary arteries associated with significant atherosclerotic lesions, which were successfully treated by 5 Fr transradial approach intervention.

  15. X-ray (image)

    MedlinePlus

    X-rays are a form of electromagnetic radiation, just like visible light. Structures that are dense (such as bone) will block most of the x-ray particles, and will appear white. Metal and contrast media ( ...

  16. X-Ray Lasers

    ERIC Educational Resources Information Center

    Chapline, George; Wood, Lowell

    1975-01-01

    Outlines the prospects of generating coherent x rays using high-power lasers and indentifies problem areas in their development. Indicates possible applications for coherent x rays in the fields of chemistry, biology, and crystallography. (GS)

  17. Prognostic Value of Cardiovascular Magnetic Resonance and Single-Photon Emission Computed Tomography in Suspected Coronary Heart Disease: Long-Term Follow-up of a Prospective, Diagnostic Accuracy Cohort Study.

    PubMed

    Greenwood, John P; Herzog, Bernhard A; Brown, Julia M; Everett, Colin C; Nixon, Jane; Bijsterveld, Petra; Maredia, Neil; Motwani, Manish; Dickinson, Catherine J; Ball, Stephen G; Plein, Sven

    2016-05-10

    There are no prospective, prognostic data comparing cardiovascular magnetic resonance (CMR) and single-photon emission computed tomography (SPECT) in the same population of patients with suspected coronary heart disease (CHD). To establish the ability of CMR and SPECT to predict major adverse cardiovascular events (MACEs). Annual follow-up of the CE-MARC (Clinical Evaluation of MAgnetic Resonance imaging in Coronary heart disease) study for a minimum of 5 years for MACEs (cardiovascular death, acute coronary syndrome, unscheduled revascularization or hospital admission for cardiovascular cause). (Current Controlled Trials registration: ISRCTN77246133). Secondary and tertiary care cardiology services. 752 patients from the CE-MARC study who were being investigated for suspected CHD. Prediction of time to MACE was assessed by using univariable (log-rank test) and multivariable (Cox proportional hazards regression) analysis. 744 (99%) of the 752 recruited patients had complete follow-up. Of 628 who underwent CMR, SPECT, and the reference standard test of X-ray angiography, 104 (16.6%) had at least 1 MACE. Abnormal findings on CMR (hazard ratio, 2.77 [95% CI, 1.85 to 4.16]; P < 0.001) and SPECT (hazard ratio, 1.62 [CI, 1.11 to 2.38; P = 0.014) were both strong and independent predictors of MACE. Only CMR remained a significant predictor after adjustment for other cardiovascular risk factors, angiography result, or stratification for initial patient treatment. Data are from a single-center observational study (albeit conducted in a high-volume institution for both CMR and SPECT). Five-year follow-up of the CE-MARC study indicates that compared with SPECT, CMR is a stronger predictor of risk for MACEs, independent of cardiovascular risk factors, angiography result, or initial patient treatment. This further supports the role of CMR as an alternative to SPECT for the diagnosis and management of patients with suspected CHD. British Heart Foundation.

  18. Nonlinear X-Ray and Auger Spectroscopy at X-Ray Free-Electron Laser Sources

    NASA Astrophysics Data System (ADS)

    Rohringer, Nina

    2015-05-01

    X-ray free-electron lasers (XFELs) open the pathway to transfer non-linear spectroscopic techniques to the x-ray domain. A promising all x-ray pump probe technique is based on coherent stimulated electronic x-ray Raman scattering, which was recently demonstrated in atomic neon. By tuning the XFEL pulse to core-excited resonances, a few seed photons in the spectral tail of the XFEL pulse drive an avalanche of resonant inelastic x-ray scattering events, resulting in exponential amplification of the scattering signal by of 6-7 orders of magnitude. Analysis of the line profile of the emitted radiation permits to demonstrate the cross over from amplified spontaneous emission to coherent stimulated resonance scattering. In combination with statistical covariance mapping, a high-resolution spectrum of the resonant inelastic scattering process can be obtained, opening the path to coherent stimulated x-ray Raman spectroscopy. An extension of these ideas to molecules and a realistic feasibility study of stimulated electronic x-ray Raman scattering in CO will be presented. Challenges to realizing stimulated electronic x-ray Raman scattering at present-day XFEL sources will be discussed, corroborated by results of a recent experiment at the LCLS XFEL. Due to the small gain cross section in molecular targets, other nonlinear spectroscopic techniques such as nonlinear Auger spectroscopy could become a powerful alternative. Theory predictions of a novel pump probe technique based on resonant nonlinear Auger spectroscopic will be discussed and the method will be compared to stimulated x-ray Raman spectroscopy.

  19. Tunable X-ray source

    DOEpatents

    Boyce, James R [Williamsburg, VA

    2011-02-08

    A method for the production of X-ray bunches tunable in both time and energy level by generating multiple photon, X-ray, beams through the use of Thomson scattering. The method of the present invention simultaneously produces two X-ray pulses that are tunable in energy and/or time.

  20. X-Ray Diffraction Apparatus

    NASA Technical Reports Server (NTRS)

    Blake, David F. (Inventor); Bryson, Charles (Inventor); Freund, Friedmann (Inventor)

    1996-01-01

    An x-ray diffraction apparatus for use in analyzing the x-ray diffraction pattern of a sample is introduced. The apparatus includes a beam source for generating a collimated x-ray beam having one or more discrete x-ray energies, a holder for holding the sample to be analyzed in the path of the beam, and a charge-coupled device having an array of pixels for detecting, in one or more selected photon energy ranges, x-ray diffraction photons produced by irradiating such a sample with said beam. The CCD is coupled to an output unit which receives input information relating to the energies of photons striking each pixel in the CCD, and constructs the diffraction pattern of photons within a selected energy range striking the CCD.

  1. X-ray shearing interferometer

    DOEpatents

    Koch, Jeffrey A [Livermore, CA

    2003-07-08

    An x-ray interferometer for analyzing high density plasmas and optically opaque materials includes a point-like x-ray source for providing a broadband x-ray source. The x-rays are directed through a target material and then are reflected by a high-quality ellipsoidally-bent imaging crystal to a diffraction grating disposed at 1.times. magnification. A spherically-bent imaging crystal is employed when the x-rays that are incident on the crystal surface are normal to that surface. The diffraction grating produces multiple beams which interfere with one another to produce an interference pattern which contains information about the target. A detector is disposed at the position of the image of the target produced by the interfering beams.

  2. Abdominal x-ray

    MedlinePlus

    ... are, or may be, pregnant. Alternative Names Abdominal film; X-ray - abdomen; Flat plate; KUB x-ray ... Guidelines Viewers & Players MedlinePlus Connect for EHRs For Developers U.S. National Library of Medicine 8600 Rockville Pike, ...

  3. X-Ray Toolkit

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    2015-10-20

    Radiographic Image Acquisition & Processing Software for Security Markets. Used in operation of commercial x-ray scanners and manipulation of x-ray images for emergency responders including State, Local, Federal, and US Military bomb technicians and analysts.

  4. Left main coronary artery disease: pathophysiology, diagnosis, and treatment.

    PubMed

    Collet, Carlos; Capodanno, Davide; Onuma, Yoshinobu; Banning, Adrian; Stone, Gregg W; Taggart, David P; Sabik, Joseph; Serruys, Patrick W

    2018-06-01

    The advent of coronary angiography in the 1960s allowed for the risk stratification of patients with stable angina. Patients with unprotected left main coronary artery disease have an increased risk of death related to the large amount of myocardium supplied by this vessel. Although coronary angiography remains the preferred imaging modality for the evaluation of left main coronary artery stenosis, this technique has important limitations. Angiograms of the left main coronary artery segment can be difficult to interpret, and almost one-third of patients can be misclassified when fractional flow reserve is used as the reference. In patients with clinically significant unprotected left main coronary artery disease, surgical revascularization was shown to improve survival compared with medical therapy and has been regarded as the treatment of choice for unprotected left main coronary artery disease. Two large-scale clinical trials published in 2016 support the usefulness of catheter-based revascularization in selected patients with unprotected left main coronary artery disease. In this Review, we describe the pathophysiology of unprotected left main coronary artery disease, discuss diagnostic approaches in light of new noninvasive and invasive imaging techniques, and detail risk stratification models to aid the Heart Team in the decision-making process for determining the best revascularization strategy for these patients.

  5. Indus-2 X-ray lithography beamline for X-ray optics and material science applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dhamgaye, V. P., E-mail: vishal@rrcat.gov.in; Lodha, G. S., E-mail: vishal@rrcat.gov.in

    2014-04-24

    X-ray lithography is an ideal technique by which high aspect ratio and high spatial resolution micro/nano structures are fabricated using X-rays from synchrotron radiation source. The technique has been used for fabricating optics (X-ray, visible and infrared), sensors and actuators, fluidics and photonics. A beamline for X-ray lithography is operational on Indus-2. The beamline offers wide lithographic window from 1-40keV photon energy and wide beam for producing microstructures in polymers upto size ∼100mm × 100mm. X-ray exposures are possible in air, vacuum and He gas environment. The air based exposures enables the X-ray irradiation of resist for lithography and alsomore » irradiation of biological and liquid samples.« less

  6. Virtual Resting Pd/Pa From Coronary Angiography and Blood Flow Modelling: Diagnostic Performance Against Fractional Flow Reserve.

    PubMed

    Papafaklis, Michail I; Muramatsu, Takashi; Ishibashi, Yuki; Bourantas, Christos V; Fotiadis, Dimitrios I; Brilakis, Emmanouil S; Garcia-Garcia, Héctor M; Escaned, Javier; Serruys, Patrick W; Michalis, Lampros K

    2018-03-01

    Fractional flow reserve (FFR) has been established as a useful diagnostic tool. The distal coronary pressure to aortic pressure (Pd/Pa) ratio at rest is a simpler physiologic index but also requires the use of the pressure wire, whereas recently proposed virtual functional indices derived from coronary imaging require complex blood flow modelling and/or are time-consuming. Our aim was to test the diagnostic performance of virtual resting Pd/Pa using routine angiographic images and a simple flow model. Three-dimensional quantitative coronary angiography (3D-QCA) was performed in 139 vessels (120 patients) with intermediate lesions assessed by FFR. The resting Pd/Pa for each lesion was assessed by computational fluid dynamics. The discriminatory power of virtual resting Pd/Pa against FFR (reference: ≤0.80) was high (area under the receiver operator characteristic curve [AUC]: 90.5% [95% CI: 85.4-95.6%]). Diagnostic accuracy, sensitivity and specificity for the optimal virtual resting Pd/Pa cut-off (≤0.94) were 84.9%, 90.4% and 81.6%, respectively. Virtual resting Pd/Pa demonstrated superior performance (p<0.001) versus 3D-QCA %area stenosis (AUC: 77.5% [95% CI: 69.8-85.3%]). There was a good correlation between virtual resting Pd/Pa and FFR (r=0.69, p<0.001). Virtual resting Pd/Pa using routine angiographic data and a simple flow model provides fast functional assessment of coronary lesions without requiring the pressure-wire and hyperaemia induction. The high diagnostic performance of virtual resting Pd/Pa for predicting FFR shows promise for using this simple/fast virtual index in clinical practice. Copyright © 2017 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  7. Compact x-ray source and panel

    DOEpatents

    Sampayon, Stephen E [Manteca, CA

    2008-02-12

    A compact, self-contained x-ray source, and a compact x-ray source panel having a plurality of such x-ray sources arranged in a preferably broad-area pixelized array. Each x-ray source includes an electron source for producing an electron beam, an x-ray conversion target, and a multilayer insulator separating the electron source and the x-ray conversion target from each other. The multi-layer insulator preferably has a cylindrical configuration with a plurality of alternating insulator and conductor layers surrounding an acceleration channel leading from the electron source to the x-ray conversion target. A power source is connected to each x-ray source of the array to produce an accelerating gradient between the electron source and x-ray conversion target in any one or more of the x-ray sources independent of other x-ray sources in the array, so as to accelerate an electron beam towards the x-ray conversion target. The multilayer insulator enables relatively short separation distances between the electron source and the x-ray conversion target so that a thin panel is possible for compactness. This is due to the ability of the plurality of alternating insulator and conductor layers of the multilayer insulators to resist surface flashover when sufficiently high acceleration energies necessary for x-ray generation are supplied by the power source to the x-ray sources.

  8. Heart imaging: the accuracy of the 64-MSCT in the detection of coronary artery disease.

    PubMed

    Alessandri, N; Di Matteo, A; Rondoni, G; Petrassi, M; Tufani, F; Ferrari, R; Laghi, A

    2009-01-01

    At present, coronary angiography represents the gold standard technique for the diagnosis of coronary artery disease. Our aim is to compare the conventional coronary angiography to the coronary 64-multislice spiral computed tomography (64-MSCT), a new and non-invasive cardiac imaging technique. The last generation of MSCT scanners show a better imaging quality, due to a greater spatial and temporal resolution. Four expert observers (two cardiologists and two radiologists) have compared the angiographic data with the accuracy of the 64-MSCT in the detection and evaluation of coronary vessels stenoses. From the data obtained, the sensibility, the specificity and the accuracy of the coronary 64-MSCT have been defined. We have enrolled 75 patients (57 male, 18 female, mean age 61.83 +/- 10.38; range 30-80 years) with known or suspected coronary artery disease. The above population has been divided into 3 groups: Group A (Gr. A) with 40 patients (mean age 60.7 +/- 12.5) affected by both non-significant and significant coronary artery disease; Group B (Gr. B) with 25 patients (mean age 60.3 +/- 14.6) who underwent to percutaneous coronary intervention (PCI); Group C (Gr. C) with 10 patients (mean age 54.20 +/- 13.7) without any coronary angiographic stenoses. All the patients underwent non-invasive exams, conventional coronary angiography and coronary 64-MSCT. The comparison of the data obtained has been carried out according to a per group analysis, per patient analysis and per segment analysis. Moreover, the accuracy of the 64-MSCT has been defined for the detection of >75%, 50-75% and <50% coronary stenoses. Coronary angiography has identified significant coronary artery disease in 75% of the patients in the Gr. A and in 73% of the patients in the Gr. B. No coronary stenoses have been detected in Gr. C. According to a per segment analysis, in Gr. A, 36% of the segments analysed have shown a coronary stenosis (37% stenoses >75%, 32% stenoses 50-75% and 31% stenoses <50

  9. Symbiotic Stars in X-rays

    NASA Technical Reports Server (NTRS)

    Luna, G. J. M.; Sokoloski, J. L.; Mukai, K.; Nelson, T.

    2014-01-01

    Until recently, symbiotic binary systems in which a white dwarf accretes from a red giant were thought to be mainly a soft X-ray population. Here we describe the detection with the X-ray Telescope (XRT) on the Swift satellite of 9 white dwarf symbiotics that were not previously known to be X-ray sources and one that was previously detected as a supersoft X-ray source. The 9 new X-ray detections were the result of a survey of 41 symbiotic stars, and they increase the number of symbiotic stars known to be X-ray sources by approximately 30%. Swift/XRT detected all of the new X-ray sources at energies greater than 2 keV. Their X-ray spectra are consistent with thermal emission and fall naturally into three distinct groups. The first group contains those sources with a single, highly absorbed hard component, which we identify as probably coming from an accretion-disk boundary layer. The second group is composed of those sources with a single, soft X-ray spectral component, which likely arises in a region where low-velocity shocks produce X-ray emission, i.e. a colliding-wind region. The third group consists of those sources with both hard and soft X-ray spectral components. We also find that unlike in the optical, where rapid, stochastic brightness variations from the accretion disk typically are not seen, detectable UV flickering is a common property of symbiotic stars. Supporting our physical interpretation of the two X-ray spectral components, simultaneous Swift UV photometry shows that symbiotic stars with harder X-ray emission tend to have stronger UV flickering, which is usually associated with accretion through a disk. To place these new observations in the context of previous work on X-ray emission from symbiotic stars, we modified and extended the alpha/beta/gamma classification scheme for symbiotic-star X-ray spectra that was introduced by Muerset et al. based upon observations with the ROSAT satellite, to include a new sigma classification for sources with

  10. X-ray laser

    DOEpatents

    Nilsen, Joseph

    1991-01-01

    An X-ray laser (10) that lases between the K edges of carbon and oxygen, i.e. between 44 and 23 Angstroms, is provided. The laser comprises a silicon (12) and dysprosium (14) foil combination (16) that is driven by two beams (18, 20) of intense line focused (22, 24) optical laser radiation. Ground state nickel-like dysprosium ions (34) are resonantly photo-pumped to their upper X-ray laser state by line emission from hydrogen-like silicon ions (32). The novel X-ray laser should prove especially useful for the microscopy of biological specimens.

  11. Observation of femtosecond X-ray interactions with matter using an X-ray–X-ray pump–probe scheme

    PubMed Central

    Inoue, Ichiro; Inubushi, Yuichi; Sato, Takahiro; Tono, Kensuke; Katayama, Tetsuo; Kameshima, Takashi; Ogawa, Kanade; Togashi, Tadashi; Owada, Shigeki; Amemiya, Yoshiyuki; Tanaka, Takashi; Hara, Toru

    2016-01-01

    Resolution in the X-ray structure determination of noncrystalline samples has been limited to several tens of nanometers, because deep X-ray irradiation required for enhanced resolution causes radiation damage to samples. However, theoretical studies predict that the femtosecond (fs) durations of X-ray free-electron laser (XFEL) pulses make it possible to record scattering signals before the initiation of X-ray damage processes; thus, an ultraintense X-ray beam can be used beyond the conventional limit of radiation dose. Here, we verify this scenario by directly observing femtosecond X-ray damage processes in diamond irradiated with extraordinarily intense (∼1019 W/cm2) XFEL pulses. An X-ray pump–probe diffraction scheme was developed in this study; tightly focused double–5-fs XFEL pulses with time separations ranging from sub-fs to 80 fs were used to excite (i.e., pump) the diamond and characterize (i.e., probe) the temporal changes of the crystalline structures through Bragg reflection. It was found that the pump and probe diffraction intensities remain almost constant for shorter time separations of the double pulse, whereas the probe diffraction intensities decreased after 20 fs following pump pulse irradiation due to the X-ray–induced atomic displacement. This result indicates that sub-10-fs XFEL pulses enable conductions of damageless structural determinations and supports the validity of the theoretical predictions of ultraintense X-ray–matter interactions. The X-ray pump–probe scheme demonstrated here would be effective for understanding ultraintense X-ray–matter interactions, which will greatly stimulate advanced XFEL applications, such as atomic structure determination of a single molecule and generation of exotic matters with high energy densities. PMID:26811449

  12. X ray spectra of X Per. [oso-8 observations

    NASA Technical Reports Server (NTRS)

    Becker, R. H.; Boldt, E. A.; Holt, S. S.; Pravdo, S. H.; Robinson-Saba, J.; Serlemitsos, P. J.; Swank, J. H.

    1978-01-01

    The cosmic X-ray spectroscopy experiment on OSO-8 observed X Per for twenty days during two observations in Feb. 1976 and Feb. 1977. The spectrum of X Per varies in phase with its 13.9 min period, hardening significantly at X-ray minimum. Unlike other X-ray binary pulsar spectra, X Per's spectra do not exhibit iron line emission or strong absorption features. The data show no evidence for a 22 hour periodicity in the X-ray intensity of X Per. These results indicate that the X-ray emission from X Per may be originating from a neutron star in a low density region far from the optically identified Be star.

  13. The impact of acquisition angle differences on three-dimensional quantitative coronary angiography.

    PubMed

    Tu, Shengxian; Holm, Niels R; Koning, Gerhard; Maeng, Michael; Reiber, Johan H C

    2011-08-01

    Three-dimensional (3D) quantitative coronary angiography (QCA) requires two angiographic views to restore vessel dimensions. This study investigated the impact of acquisition angle differences (AADs) of the two angiographic views on the assessed dimensions by 3D QCA. X-ray angiograms of an assembled brass phantom with different types of straight lesions were recorded at multiple angiographic projections. The projections were randomly matched as pairs and 3D QCA was performed in those pairs with AAD larger than 25°. The lesion length and diameter stenosis in three different lesions, a circular concentric severe lesion (A), a circular concentric moderate lesion (B), and a circular eccentric moderate lesion (C), were measured by 3D QCA. The acquisition protocol was repeated for a silicone bifurcation phantom, and the bifurcation angles and bifurcation core volume were measured by 3D QCA. The measurements were compared with the true dimensions if applicable and their correlation with AAD was studied. 50 matched pairs of angiographic views were analyzed for the brass phantom. The average value of AAD was 48.0 ± 14.1°. The percent diameter stenosis was slightly overestimated by 3D QCA for all lesions: A (error 1.2 ± 0.9%, P < 0.001); B (error 0.6 ± 0.5%, P < 0.001); C (error 1.1 ± 0.6%, P < 0.001). The correlation of the measurements with AAD was only significant for lesion A (R(2) = 0.151, P = 0.005). The lesion length was slightly overestimated by 3D QCA for lesion A (error 0.06 ± 0.18 mm, P = 0.026), but well assessed for lesion B (error -0.00 ± 0.16 mm, P = 0.950) and lesion C (error -0.01 ± 0.18 mm, P = 0.585). The correlation of the measurements with AAD was not significant for any lesion. Forty matched pairs of angiographic views were analyzed for the bifurcation phantom. The average value of AAD was 49.1 ± 15.4°. 3D QCA slightly overestimated the proximal angle (error 0.4 ± 1.1°, P = 0.046) and the distal angle (error 1.5 ± 1.3°, P < 0.001). The

  14. Magnetic navigation system and CT roadmap-assisted percutaneous coronary intervention: a comparison to the conventional approach.

    PubMed

    Hao, Ruina; Zhang, Qiu; Xu, Zhuowen; Tang, Lijun; Yang, Zhijian; Cao, Kejiang; Li, Chunjian

    2013-04-01

    Computed tomography coronary angiography (CTCA) has been successfully integrated with the magnetic navigation system (MNS) to facilitate a roadmap-assisted percutaneous coronary intervention (PCI). The aim of this study was to compare this new approach of PCI versus conventional PCI regarding the difference of contrast usage, x-ray exposure, procedure success, and in-hospital expenses. Thirty-eight patients with stable coronary artery disease and coronary artery lesions of ≥70% diameter stenosis diagnosed by both pre-procedure CTCA and coronary angiography (CAG) were enrolled to receive the MNS and CT roadmap-assisted PCI. Another 38 patients were consecutively recruited to receive conventional PCI, matched with the MNS group by the vessel and lesion type base on American College of Cardiology/American Heart Association criteria. Regarding the process of the guidewire placement, wherein the technical difference of the two procedures exists, the median contrast usage for guidewire crossing was significantly lower in the MNS group than in the conventional group [0.0 mL (interquartile range [IQR], 0.0-3.0 mL) vs 5.0 mL (IQR, 3.1-6.8 mL); P<.001], with zero contrast usage in 25 of the 44 guidewire placements in the MNS group, but in none of the conventional group; the radiation dosage for guidewire crossing in the MNS group was also significantly lower than in the conventional group (235.8 μGym² [IQR, 134.9-455.1 μGym²] vs 364.4 μGym² [IQR, 223.4-547.2 μGym²]; P=.033). There were no significant differences between the two groups concerning the total contrast usage, total radiation dosage of the PCI, the procedural fees, or the overall in-hospital expenses. All of the enrolled vessels were successfully intervened in both groups. In PCI of simple lesions, the application of CT guidance and magnetic navigation had modest impacts on radiation dosage and contrast usage for wire crossing, but no impact on overall radiation dosage or contrast usage for the procedure

  15. Accretion and Outflows in X-ray Binaries: What's Really Going on During X-ray Quiescence

    NASA Astrophysics Data System (ADS)

    MacDonald, Rachel K. D.; Bailyn, Charles D.; Buxton, Michelle

    2015-01-01

    X-ray binaries, consisting of a star and a stellar-mass black hole, are wonderful laboratories for studying accretion and outflows. They evolve on timescales quite accessible to us, unlike their supermassive cousins, and allow the possibility of gaining a deeper understanding of these two common astrophysical processes. Different wavelength regimes reveal different aspects of the systems: radio emission is largely generated by outflows and jets, X-ray emission by inner accretion flows, and optical/infrared (OIR) emission by the outer disk and companion star. The search for relationships between these different wavelengths is thus an area of active research, aiming to reveal deeper connections between accretion and outflows.Initial evidence for a strong, tight correlation between radio and X-ray emission has weakened as further observations and newly-discovered sources have been obtained. This has led to discussions of multiple tracks or clusters, or the possibility that no overall relation exists for the currently-known population of X-ray binaries. Our ability to distinguish among these options is hampered by a relative lack of observations at lower luminosities, and especially of truly X-ray quiescent (non-outbursting) systems. Although X-ray binaries spend the bulk of their existence in quiescence, few quiescent sources have been observed and multiple observations of individual sources are largely nonexistent. Here we discuss new observations of the lowest-luminosity quiescent X-ray binary, A0620-00, and the place this object occupies in investigations of the radio/X-ray plane. For the first time, we also incorporate simultaneous OIR data with the radio and X-ray data.In December 2013 we took simultaneous observations of A0620-00 in the X-ray (Chandra), the radio (EVLA), and the OIR (SMARTS 1.3m). These X-ray and radio data allowed us to investigate similarities among quiescent X-ray binaries, and changes over time for this individual object, in the radio/X-ray

  16. Future Hard X-ray and Gamma-Ray Missions

    NASA Astrophysics Data System (ADS)

    Krawczynski, Henric; Physics of the Cosmos (PCOS) Gamma Ray Science Interest Group (GammaSIG) Team

    2017-01-01

    With four major NASA and ESA hard X-ray and gamma-ray missions in orbit (Swift, NuSTAR, INTEGRAL, and Fermi) hard X-ray and gamma-ray astronomy is making major contributions to our understanding of the cosmos. In this talk, I will summarize the current and upcoming activities of the Physics of the Cosmos Gamma Ray Science Interest Group and highlight a few of the future hard X-ray and gamma-ray mission discussed by the community. HK thanks NASA for the support through the awards NNX14AD19G and NNX16AC42G and for PCOS travel support.

  17. Effects of X-Ray Dose On Rhizosphere Studies Using X-Ray Computed Tomography

    PubMed Central

    Zappala, Susan; Helliwell, Jonathan R.; Tracy, Saoirse R.; Mairhofer, Stefan; Sturrock, Craig J.; Pridmore, Tony; Bennett, Malcolm; Mooney, Sacha J.

    2013-01-01

    X-ray Computed Tomography (CT) is a non-destructive imaging technique originally designed for diagnostic medicine, which was adopted for rhizosphere and soil science applications in the early 1980s. X-ray CT enables researchers to simultaneously visualise and quantify the heterogeneous soil matrix of mineral grains, organic matter, air-filled pores and water-filled pores. Additionally, X-ray CT allows visualisation of plant roots in situ without the need for traditional invasive methods such as root washing. However, one routinely unreported aspect of X-ray CT is the potential effect of X-ray dose on the soil-borne microorganisms and plants in rhizosphere investigations. Here we aimed to i) highlight the need for more consistent reporting of X-ray CT parameters for dose to sample, ii) to provide an overview of previously reported impacts of X-rays on soil microorganisms and plant roots and iii) present new data investigating the response of plant roots and microbial communities to X-ray exposure. Fewer than 5% of the 126 publications included in the literature review contained sufficient information to calculate dose and only 2.4% of the publications explicitly state an estimate of dose received by each sample. We conducted a study involving rice roots growing in soil, observing no significant difference between the numbers of root tips, root volume and total root length in scanned versus unscanned samples. In parallel, a soil microbe experiment scanning samples over a total of 24 weeks observed no significant difference between the scanned and unscanned microbial biomass values. We conclude from the literature review and our own experiments that X-ray CT does not impact plant growth or soil microbial populations when employing a low level of dose (<30 Gy). However, the call for higher throughput X-ray CT means that doses that biological samples receive are likely to increase and thus should be closely monitored. PMID:23840640

  18. Phase-sensitive X-ray imager

    DOEpatents

    Baker, Kevin Louis

    2013-01-08

    X-ray phase sensitive wave-front sensor techniques are detailed that are capable of measuring the entire two-dimensional x-ray electric field, both the amplitude and phase, with a single measurement. These Hartmann sensing and 2-D Shear interferometry wave-front sensors do not require a temporally coherent source and are therefore compatible with x-ray tubes and also with laser-produced or x-pinch x-ray sources.

  19. Toward Adaptive X-Ray Telescopes

    NASA Technical Reports Server (NTRS)

    O'Dell, Stephen L.; Atkins, Carolyn; Button, Tim W.; Cotroneo, Vincenzo; Davis, William N.; Doel, Peer; Feldman, Charlotte H.; Freeman, Mark D.; Gubarev, Mikhail V.; Kolodziejczak, Jeffrey J.; hide

    2011-01-01

    Future x-ray observatories will require high-resolution (less than 1 inch) optics with very-large-aperture (greater than 25 square meter) areas. Even with the next generation of heavy-lift launch vehicles, launch-mass constraints and aperture-area requirements will limit the surface areal density of the grazing-incidence mirrors to about 1 kilogram per square meter or less. Achieving sub-arcsecond x-ray imaging with such lightweight mirrors will require excellent mirror surfaces, precise and stable alignment, and exceptional stiffness or deformation compensation. Attaining and maintaining alignment and figure control will likely involve adaptive (in-space adjustable) x-ray optics. In contrast with infrared and visible astronomy, adaptive optics for x-ray astronomy is in its infancy. In the middle of the past decade, two efforts began to advance technologies for adaptive x-ray telescopes: The Generation-X (Gen-X) concept studies in the United States, and the Smart X-ray Optics (SXO) Basic Technology project in the United Kingdom. This paper discusses relevant technological issues and summarizes progress toward adaptive x-ray telescopes.

  20. Toward active x-ray telescopes

    NASA Astrophysics Data System (ADS)

    O'Dell, Stephen L.; Atkins, Carolyn; Button, Timothy W.; Cotroneo, Vincenzo; Davis, William N.; Doel, Peter; Feldman, Charlotte H.; Freeman, Mark D.; Gubarev, Mikhail V.; Kolodziejczak, Jeffery J.; Michette, Alan G.; Ramsey, Brian D.; Reid, Paul B.; Rodriguez Sanmartin, Daniel; Saha, Timo T.; Schwartz, Daniel A.; Trolier-McKinstry, Susan; Wilke, Rudeger H. T.; Willingale, Richard; Zhang, William W.

    2011-09-01

    Future x-ray observatories will require high-resolution (< 1") optics with very-large-aperture (> 25 m2) areas. Even with the next generation of heavy-lift launch vehicles, launch-mass constraints and aperture-area requirements will limit the areal density of the grazing-incidence mirrors to about 1 kg/m2 or less. Achieving sub-arcsecond x-ray imaging with such lightweight mirrors will require excellent mirror surfaces, precise and stable alignment, and exceptional stiffness or deformation compensation. Attaining and maintaining alignment and figure control will likely involve active (in-space adjustable) x-ray optics. In contrast with infrared and visible astronomy, active optics for x-ray astronomy is in its infancy. In the middle of the past decade, two efforts began to advance technologies for adaptive x-ray telescopes: The Smart X-ray Optics (SXO) Basic Technology project in the United Kingdom (UK) and the Generation-X (Gen-X) concept studies in the United States (US). This paper discusses relevant technological issues and summarizes progress toward active x-ray telescopes.

  1. Fractional flow reserve versus angiography for guidance of PCI in patients with multivessel coronary artery disease (FAME): 5-year follow-up of a randomised controlled trial.

    PubMed

    van Nunen, Lokien X; Zimmermann, Frederik M; Tonino, Pim A L; Barbato, Emanuele; Baumbach, Andreas; Engstrøm, Thomas; Klauss, Volker; MacCarthy, Philip A; Manoharan, Ganesh; Oldroyd, Keith G; Ver Lee, Peter N; Van't Veer, Marcel; Fearon, William F; De Bruyne, Bernard; Pijls, Nico H J

    2015-11-07

    In the Fractional Flow Reserve Versus Angiography for Multivessel Evaluation (FAME) study, fractional flow reserve (FFR)-guided percutaneous coronary intervention (PCI) improved outcome compared with angiography-guided PCI for up to 2 years of follow-up. The aim in this study was to investigate whether the favourable clinical outcome with the FFR-guided PCI in the FAME study persisted over a 5-year follow-up. The FAME study was a multicentre trial done in Belgium, Denmark, Germany, the Netherlands, Sweden, the UK, and the USA. Patients (aged ≥ 18 years) with multivessel coronary artery disease were randomly assigned to undergo angiography-guided PCI or FFR-guided PCI. Before randomisation, stenoses requiring PCI were identified on the angiogram. Patients allocated to angiography-guided PCI had revascularisation of all identified stenoses. Patients allocated to FFR-guided PCI had FFR measurements of all stenotic arteries and PCI was done only if FFR was 0·80 or less. No one was masked to treatment assignment. The primary endpoint was major adverse cardiac events at 1 year, and the data for the 5-year follow-up are reported here. Analysis was by intention to treat. This trial is registered with ClinicalTrials.gov, number NCT00267774. After 5 years, major adverse cardiac events occurred in 31% of patients (154 of 496) in the angiography-guided group versus 28% (143 of 509 patients) in the FFR-guided group (relative risk 0·91, 95% CI 0·75-1·10; p=0·31). The number of stents placed per patient was significantly higher in the angiography-guided group than in the FFR-guided group (mean 2·7 [SD 1·2] vs 1·9 [1·3], p<0·0001). The results confirm the long-term safety of FFR-guided PCI in patients with multivessel disease. A strategy of FFR-guided PCI resulted in a significant decrease of major adverse cardiac events for up to 2 years after the index procedure. From 2 years to 5 years, the risks for both groups developed similarly. This clinical outcome in the FFR

  2. Quantification of epicardial adipose tissue in coronary calcium score and CT coronary angiography image data sets: comparison of attenuation values, thickness and volumes.

    PubMed

    La Grutta, Ludovico; Toia, Patrizia; Farruggia, Alfonso; Albano, Domenico; Grassedonio, Emanuele; Palmeri, Antonella; Maffei, Erica; Galia, Massimo; Vitabile, Salvatore; Cademartiri, Filippo; Midiri, Massimo

    2016-06-01

    The aim of the study was to compare epicardial adipose tissue (EAT) characteristics assessed with coronary calcium score (CS) and CT coronary angiography (CTCA) image data sets. In 76 patients (mean age 59 ± 13 years) who underwent CS and CTCA owing to suspected coronary artery disease (CAD), EAT was quantified in terms of density (Hounsfield units), thickness and volume. The EAT volume was extracted with a semi-automatic software. A moderate correlation was found between EAT density in CS and CTCA image data sets (-100 ± 19 HU vs -70 ± 24 HU; p < 0.05, r = 0.55). The distribution of EAT was not symmetrical with a maximal thickness at the right atrioventricular groove (14.2 ± 5.3 mm in CS, 15.7 ± 5 mm in CTCA; p > 0.05, r = 0.76). The EAT volume resulted as 122 ± 50 cm(3) in CS and 86 ± 40 cm(3) in CTCA (Δ = 30%, p < 0.05, r = 0.92). After adjustment for post-contrast EAT attenuation difference (Δ = 30 HU), the volume was 101 ± 47 cm(3) (Δ = 17%, p < 0.05, r = 0.92). Based on EAT volume median values, no differences were found between groups with smaller and larger volumes in terms of Agatston score and CAD severity. CS and CTCA image data sets may be equally employed for EAT assessment; however, an underestimation of volume is found with the latter acquisition even after post-contrast attenuation adjustment. EAT may be measured by processing either the CS or CTCA image data sets.

  3. X-ray superbubbles

    NASA Technical Reports Server (NTRS)

    Cash, W.

    1983-01-01

    Four regions of the galaxy, the Cygnus Superbubble, the Eta Carina complex, the Orion/Eridanus complex, and the Gum Nebula, are discussed as examples of collective effects in the interstellar medium. All four regions share certain features, indicating a common structure. The selection effects which determine the observable X-ray properties of the superbubbles are discussed, and it is demonstrated that only a very few more in our Galaxy can be detected in X rays. X-ray observation of extragalactic superbubbles is shown to be possible but requires the capabilities of a large, high quality, AXAF class observatory.

  4. X-ray transmissive debris shield

    DOEpatents

    Spielman, R.B.

    1996-05-21

    An X-ray debris shield for use in X-ray lithography that is comprised of an X-ray window having a layer of low density foam exhibits increased longevity without a substantial increase in exposure time. The low density foam layer serves to absorb the debris emitted from the X-ray source and attenuate the shock to the window so as to reduce the chance of breakage. Because the foam is low density, the X-rays are hardly attenuated by the foam and thus the exposure time is not substantially increased.

  5. X-ray transmissive debris shield

    DOEpatents

    Spielman, Rick B.

    1996-01-01

    An X-ray debris shield for use in X-ray lithography that is comprised of an X-ray window having a layer of low density foam exhibits increased longevity without a substantial increase in exposure time. The low density foam layer serves to absorb the debris emitted from the X-ray source and attenuate the shock to the window so as to reduce the chance of breakage. Because the foam is low density, the X-rays are hardly attenuated by the foam and thus the exposure time is not substantially increased.

  6. Topological X-Rays Revisited

    ERIC Educational Resources Information Center

    Lynch, Mark

    2012-01-01

    We continue our study of topological X-rays begun in Lynch ["Topological X-rays and MRI's," iJMEST 33(3) (2002), pp. 389-392]. We modify our definition of a topological magnetic resonance imaging and give an affirmative answer to the question posed there: Can we identify a closed set in a box by defining X-rays to probe the interior and without…

  7. X-ray Crystallography Facility

    NASA Technical Reports Server (NTRS)

    2000-01-01

    Edward Snell, a National Research Council research fellow at NASA's Marshall Space Flight Center (MSFC), prepares a protein crystal for analysis by x-ray crystallography as part of NASA's structural biology program. The small, individual crystals are bombarded with x-rays to produce diffraction patterns, a map of the intensity of the x-rays as they reflect through the crystal.

  8. Diagnostic accuracy of 256-row multidetector CT coronary angiography with prospective ECG-gating combined with fourth-generation iterative reconstruction algorithm in the assessment of coronary artery bypass: evaluation of dose reduction and image quality.

    PubMed

    Ippolito, Davide; Fior, Davide; Franzesi, Cammillo Talei; Riva, Luca; Casiraghi, Alessandra; Sironi, Sandro

    2017-12-01

    Effective radiation dose in coronary CT angiography (CTCA) for coronary artery bypass graft (CABG) evaluation is remarkably high because of long scan lengths. Prospective electrocardiographic gating with iterative reconstruction can reduce effective radiation dose. To evaluate the diagnostic performance of low-kV CT angiography protocol with prospective ecg-gating technique and iterative reconstruction (IR) algorithm in follow-up of CABG patients compared with standard retrospective protocol. Seventy-four non-obese patients with known coronary disease treated with artery bypass grafting were prospectively enrolled. All the patients underwent 256 MDCT (Brilliance iCT, Philips) CTCA using low-dose protocol (100 kV; 800 mAs; rotation time: 0.275 s) combined with prospective ECG-triggering acquisition and fourth-generation IR technique (iDose 4 ; Philips); all the lengths of the bypass graft were included in the evaluation. A control group of 42 similar patients was evaluated with a standard retrospective ECG-gated CTCA (100 kV; 800 mAs).On both CT examinations, ROIs were placed to calculate standard deviation of pixel values and intra-vessel density. Diagnostic quality was also evaluated using a 4-point quality scale. Despite the statistically significant reduction of radiation dose evaluated with DLP (study group mean DLP: 274 mGy cm; control group mean DLP: 1224 mGy cm; P value < 0.001). No statistical differences were found between PGA group and RGH group regarding intra-vessel density absolute values and SNR. Qualitative analysis, evaluated by two radiologists in "double blind", did not reveal any significant difference in diagnostic quality of the two groups. The development of high-speed MDCT scans combined with modern IR allows an accurate evaluation of CABG with prospective ECG-gating protocols in a single breath hold, obtaining a significant reduction in radiation dose.

  9. X-ray lithography using holographic images

    DOEpatents

    Howells, Malcolm R.; Jacobsen, Chris

    1995-01-01

    A non-contact X-ray projection lithography method for producing a desired X-ray image on a selected surface of an X-ray-sensitive material, such as photoresist material on a wafer, the desired X-ray image having image minimum linewidths as small as 0.063 .mu.m, or even smaller. A hologram and its position are determined that will produce the desired image on the selected surface when the hologram is irradiated with X-rays from a suitably monochromatic X-ray source of a selected wavelength .lambda.. On-axis X-ray transmission through, or off-axis X-ray reflection from, a hologram may be used here, with very different requirements for monochromaticity, flux and brightness of the X-ray source. For reasonable penetration of photoresist materials by X-rays produced by the X-ray source, the wavelength X, is preferably chosen to be no more than 13.5 nm in one embodiment and more preferably is chosen in the range 1-5 nm in the other embodiment. A lower limit on linewidth is set by the linewidth of available microstructure writing devices, such as an electron beam.

  10. Development of polycapillary x-ray optics for x-ray spectroscopy

    NASA Astrophysics Data System (ADS)

    Adams, Bernhard W.; Attenkofer, Klaus; Bond, Justin L.; Craven, Christopher A.; Cremer, Till; O'Mahony, Aileen; Minot, Michael J.; Popecki, Mark A.

    2016-09-01

    Bundles of hollow glass capillaries can be tapered to produce quasi-focusing x-ray optics. These optics are known as Kumakhov lenses. These optics are interesting for lab-based sources because they can be used to collimate and concentrate x-rays originating from a point, such as a laser focus or an electron-beam focus in a microtube.

  11. X-ray Spectrometry.

    ERIC Educational Resources Information Center

    Markowicz, Andrzej A.; Van Grieken, Rene E.

    1984-01-01

    Provided is a selective literature survey of X-ray spectrometry from late 1981 to late 1983. Literature examined focuses on: excitation (photon and electron excitation and particle-induced X-ray emission; detection (wavelength-dispersive and energy-dispersive spectrometry); instrumentation and techniques; and on such quantitative analytical…

  12. Exploring the X-Ray Universe

    NASA Astrophysics Data System (ADS)

    Seward, Frederick D.; Charles, Philip A.

    1995-11-01

    Exploring the X-Ray Universe describes the view of the stars and galaxies that is obtained through X-ray telescopes. X-rays, which are invisible to human sight, are created in the cores of active galaxies, in cataclysmic stellar explosions, and in streams of gas expelled by the Sun and stars. The window on the heavens used by the X-ray astronomers shows the great drama of cosmic violence on the grandest scale.

    This account of X-ray astronomy incorporates the latest findings from several observatories operating in space. These include the Einstein Observatory operated by NASA, and the EXOSAT satellite of the European Space Agency. The book covers the entire field, with chapters on stars, supernova remnants, normal and active galaxies, clusters of galaxies, the diffuse X-ray background, and much more. The authors review basic principles, include the necessary historical background, and explain exactly what we know from X-ray observations of the Universe.

  13. X-ray imaging physics for nuclear medicine technologists. Part 1: Basic principles of x-ray production.

    PubMed

    Seibert, J Anthony

    2004-09-01

    The purpose is to review in a 4-part series: (i) the basic principles of x-ray production, (ii) x-ray interactions and data capture/conversion, (iii) acquisition/creation of the CT image, and (iv) operational details of a modern multislice CT scanner integrated with a PET scanner. Advances in PET technology have lead to widespread applications in diagnostic imaging and oncologic staging of disease. Combined PET/CT scanners provide the high-resolution anatomic imaging capability of CT with the metabolic and physiologic information by PET, to offer a significant increase in information content useful for the diagnostician and radiation oncologist, neurosurgeon, or other physician needing both anatomic detail and knowledge of disease extent. Nuclear medicine technologists at the forefront of PET should therefore have a good understanding of x-ray imaging physics and basic CT scanner operation, as covered by this 4-part series. After reading the first article on x-ray production, the nuclear medicine technologist will be familiar with (a) the physical characteristics of x-rays relative to other electromagnetic radiations, including gamma-rays in terms of energy, wavelength, and frequency; (b) methods of x-ray production and the characteristics of the output x-ray spectrum; (c) components necessary to produce x-rays, including the x-ray tube/x-ray generator and the parameters that control x-ray quality (energy) and quantity; (d) x-ray production limitations caused by heating and the impact on image acquisition and clinical throughput; and (e) a glossary of terms to assist in the understanding of this information.

  14. [ECG and ST-elevation myocardial infarction in multivessel coronary disease].

    PubMed

    Slavich, Gianaugusto; Spedicato, Leonardo; Poli, Stefano; Sappa, Roberta; Piccoli, Gianluca

    2010-12-01

    Percutaneous coronary intervention is the first-line treatment for ST-elevation myocardial infarction. In the setting of multivessel disease, concomitant reperfusion of all obstructed vessels is controversial, notably when the culprit vessel cannot be easily identified. We describe two cases with acute inferior-posterior myocardial infarction (ST-segment elevation in the inferior leads and ST-segment depression in the precordial leads). In the first case, angiography revealed severe three-vessel disease and the culprit vessel could not be identified. Following standard pharmacological therapy, the clinical picture and the ECG pattern improved, so that coronary revascularization was postponed. In the second case, angiography showed two-vessel disease with total occlusion of the right coronary and left circumflex arteries, which was treated with coronary angioplasty and drug-eluting stent implantation on the right coronary artery. In patients who undergo coronary angioplasty immediately, careful reading of the ECG can be a reliable tool for the identification of the culprit vessel in ST-elevation myocardial infarction associated with multivessel disease, allowing to choose the appropriate reperfusion strategy.

  15. Pitfalls in 16-detector row CT of the coronary arteries.

    PubMed

    Nakanishi, Tadashi; Kayashima, Yasuyo; Inoue, Rintaro; Sumii, Kotaro; Gomyo, Yukihiko

    2005-01-01

    Recently developed 16-detector row computed tomography (CT) has been introduced as a reliable noninvasive imaging modality for evaluating the coronary arteries. In most cases, with appropriate premedication that includes beta-blockers and nitroglycerin, ideal data sets can be acquired from which to obtain excellent-quality coronary CT angiograms, most often with multiplanar reformation, thin-slab maximum intensity projection, and volume rendering. However, various artifacts associated with data creation and reformation, postprocessing methods, and image interpretation can hamper accurate diagnosis. These artifacts can be related to pulsation (nonassessable segments, pseudostenosis) as well as rhythm disorders, respiratory issues, partial volume averaging effect, high-attenuation entities, inappropriate scan pitch, contrast material enhancement, and patient body habitus. Some artifacts have already been resolved with technical advances, whereas others represent partially inherent limitations of coronary CT angiography. Familiarity with the pitfalls of coronary angiography with 16-detector row CT, coupled with the knowledge of both the normal anatomy and anatomic variants of the coronary arteries, can almost always help radiologists avoid interpretive errors in the diagnosis of coronary artery stenosis. (c) RSNA, 2005.

  16. Clinical outcomes of fractional flow reserve by computed tomographic angiography-guided diagnostic strategies vs. usual care in patients with suspected coronary artery disease: the prospective longitudinal trial of FFR(CT): outcome and resource impacts study.

    PubMed

    Douglas, Pamela S; Pontone, Gianluca; Hlatky, Mark A; Patel, Manesh R; Norgaard, Bjarne L; Byrne, Robert A; Curzen, Nick; Purcell, Ian; Gutberlet, Matthias; Rioufol, Gilles; Hink, Ulrich; Schuchlenz, Herwig Walter; Feuchtner, Gudrun; Gilard, Martine; Andreini, Daniele; Jensen, Jesper M; Hadamitzky, Martin; Chiswell, Karen; Cyr, Derek; Wilk, Alan; Wang, Furong; Rogers, Campbell; De Bruyne, Bernard

    2015-12-14

    In symptomatic patients with suspected coronary artery disease (CAD), computed tomographic angiography (CTA) improves patient selection for invasive coronary angiography (ICA) compared with functional testing. The impact of measuring fractional flow reserve by CTA (FFRCT) is unknown. At 11 sites, 584 patients with new onset chest pain were prospectively assigned to receive either usual testing (n = 287) or CTA/FFR(CT) (n = 297). Test interpretation and care decisions were made by the clinical care team. The primary endpoint was the percentage of those with planned ICA in whom no significant obstructive CAD (no stenosis ≥50% by core laboratory quantitative analysis or invasive FFR < 0.80) was found at ICA within 90 days. Secondary endpoints including death, myocardial infarction, and unplanned revascularization were independently and blindly adjudicated. Subjects averaged 61 ± 11 years of age, 40% were female, and the mean pre-test probability of obstructive CAD was 49 ± 17%. Among those with intended ICA (FFR(CT)-guided = 193; usual care = 187), no obstructive CAD was found at ICA in 24 (12%) in the CTA/FFR(CT) arm and 137 (73%) in the usual care arm (risk difference 61%, 95% confidence interval 53-69, P< 0.0001), with similar mean cumulative radiation exposure (9.9 vs. 9.4 mSv, P = 0.20). Invasive coronary angiography was cancelled in 61% after receiving CTA/FFR(CT) results. Among those with intended non-invasive testing, the rates of finding no obstructive CAD at ICA were 13% (CTA/FFR(CT)) and 6% (usual care; P = 0.95). Clinical event rates within 90 days were low in usual care and CTA/FFR(CT) arms. Computed tomographic angiography/fractional flow reserve by CTA was a feasible and safe alternative to ICA and was associated with a significantly lower rate of invasive angiography showing no obstructive CAD. © The Author 2015. Published by Oxford University Press on behalf of the European Society of Cardiology.

  17. Implementation of a channelized Hotelling observer model to assess image quality of x-ray angiography systems.

    PubMed

    Favazza, Christopher P; Fetterly, Kenneth A; Hangiandreou, Nicholas J; Leng, Shuai; Schueler, Beth A

    2015-01-01

    Evaluation of flat-panel angiography equipment through conventional image quality metrics is limited by the scope of standard spatial-domain image quality metric(s), such as contrast-to-noise ratio and spatial resolution, or by restricted access to appropriate data to calculate Fourier domain measurements, such as modulation transfer function, noise power spectrum, and detective quantum efficiency. Observer models have been shown capable of overcoming these limitations and are able to comprehensively evaluate medical-imaging systems. We present a spatial domain-based channelized Hotelling observer model to calculate the detectability index (DI) of our different sized disks and compare the performance of different imaging conditions and angiography systems. When appropriate, changes in DIs were compared to expectations based on the classical Rose model of signal detection to assess linearity of the model with quantum signal-to-noise ratio (SNR) theory. For these experiments, the estimated uncertainty of the DIs was less than 3%, allowing for precise comparison of imaging systems or conditions. For most experimental variables, DI changes were linear with expectations based on quantum SNR theory. DIs calculated for the smallest objects demonstrated nonlinearity with quantum SNR theory due to system blur. Two angiography systems with different detector element sizes were shown to perform similarly across the majority of the detection tasks.

  18. X-ray absorption spectroscopy: EXAFS (Extended X-ray Absorption Fine Structure) and XANES (X-ray Absorption Near Edge Structure)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alp, E.E.; Mini, S.M.; Ramanathan, M.

    1990-04-01

    The x-ray absorption spectroscopy (XAS) had been an essential tool to gather spectroscopic information about atomic energy level structure in the early decades of this century. It has also played an important role in the discovery and systematization of rare-earth elements. The discovery of synchrotron radiation in 1952, and later the availability of broadly tunable synchrotron based x-ray sources have revitalized this technique since the 1970's. The correct interpretation of the oscillatory structure in the x-ray absorption cross-section above the absorption edge by Sayers et. al. has transformed XAS from a spectroscopic tool to a structural technique. EXAFS (Extended X-raymore » Absorption Fine Structure) yields information about the interatomic distances, near neighbor coordination numbers, and lattice dynamics. An excellent description of the principles and data analysis techniques of EXAFS is given by Teo. XANES (X-ray Absorption Near Edge Structure), on the other hand, gives information about the valence state, energy bandwidth and bond angles. Today, there are about 50 experimental stations in various synchrotrons around the world dedicated to collecting x-ray absorption data from the bulk and surfaces of solids and liquids. In this chapter, we will give the basic principles of XAS, explain the information content of essentially two different aspects of the absorption process leading to EXAFS and XANES, and discuss the source and samples limitations.« less

  19. X-ray radiative transfer in protoplanetary disks. The role of dust and X-ray background fields

    NASA Astrophysics Data System (ADS)

    Rab, Ch.; Güdel, M.; Woitke, P.; Kamp, I.; Thi, W.-F.; Min, M.; Aresu, G.; Meijerink, R.

    2018-01-01

    Context. The X-ray luminosities of T Tauri stars are about two to four orders of magnitude higher than the luminosity of the contemporary Sun. As these stars are born in clusters, their disks are not only irradiated by their parent star but also by an X-ray background field produced by the cluster members. Aims: We aim to quantify the impact of X-ray background fields produced by young embedded clusters on the chemical structure of disks. Further, we want to investigate the importance of the dust for X-ray radiative transfer in disks. Methods: We present a new X-ray radiative transfer module for the radiation thermo-chemical disk code PRODIMO (PROtoplanetary DIsk MOdel), which includes X-ray scattering and absorption by both the gas and dust component. The X-ray dust opacities can be calculated for various dust compositions and dust-size distributions. For the X-ray radiative transfer we consider irradiation by the star and by X-ray background fields. To study the impact of X-rays on the chemical structure of disks we use the well established disk ionization tracers N2H+ and HCO+. Results: For evolved dust populations (e.g. grain growth), X-ray opacities are mostly dominated by the gas; only for photon energies E ≳ 5-10 keV do dust opacities become relevant. Consequently the local disk X-ray radiation field is only affected in dense regions close to the disk midplane. X-ray background fields can dominate the local X-ray disk ionization rate for disk radii r ≳ 20 au. However, the N2H+ and HCO+ column densities are only significantly affected in cases of low cosmic-ray ionization rates (≲10-19 s-1), or if the background flux is at least a factor of ten higher than the flux level of ≈10-5 erg cm-2 s-1 expected for clusters typical for the solar vicinity. Conclusions: Observable signatures of X-ray background fields in low-mass star-formation regions, like Taurus, are only expected for cluster members experiencing a strong X-ray background field (e.g. due to

  20. [Single coronary artery and right aortic arch].

    PubMed

    Martínez-Quintana, Efrén; Rodríguez-González, Fayna

    2015-01-01

    Coronary anomalies are mostly asymptomatic and diagnosed incidentally during coronary angiography or echocardiography. However, they must be taken into account in the differential diagnosis of angina, dyspnea, syncope, acute myocardial infarction or sudden death in young patients. The case is presented of two rare anomalies, single coronary artery originating from right sinus of Valsalva and right aortic arch, in a 65 year-old patient with atherosclerotic coronary artery disease treated percutaneously. Copyright © 2014 Sociedad Española de Arteriosclerosis. Published by Elsevier España. All rights reserved.